Sample records for urine samples showed

  1. Urine melanin test

    MedlinePlus

    Thormahlen's test; Melanin - urine ... A clean-catch urine sample is needed. ... this substance that it shows up in the urine. ... Normally, melanin is not present in urine. Normal value ranges may ... measurements or test different samples. Talk to your health ...

  2. The method of urine sampling is not a valid predictor for vesicoureteral reflux in children after febrile urinary tract infections.

    PubMed

    Haid, Bernhard; Roesch, Judith; Strasser, Christa; Oswald, Josef

    2017-10-01

    The likelihood of detecting vesicoureteral reflux (VUR) after febrile urinary tract infections (UTI) in children logically should correlate with the correct diagnosis of the UTI. Beneath the unspecific symptoms of fever urine analysis is the main diagnostic criterion for the exact diagnosis of febrile UTIs in children. Use of inadequate urine sampling techniques during diagnosis may lead to impaired accuracy in UTI diagnosis. This could lead to the assumption that children, having diagnosed their UTI by the use of possibly inadequate urine sampling techniques should not be evaluated as consequently compared to those, where the diagnosis relied on sterile urine sampling techniques. We hypothesized that children with possibly contaminated urine samples during the initial diagnosis may show a lower rate of VUR in subsequent VCUGs because of a wrong diagnosis initially compared to children, where accurate urine sampling techniques were used. Between 2009 and 2014, a total of 555 patients underwent a primary VCUG at our department indicated because of febrile UTIs. Patients with urine collection methods other than bag urine and catheter/suprapubic aspiration (SPA) were excluded from this study (mid-stream urine, potty urine, n = 149). We evaluated 402 patients (male/female 131/271, mean age 1.91 years), VUR rates and grades were compared between patients where urine was sampled by the use of a urine bag only at the time of diagnosis (n = 296, 73.6%) and those where sterile urine sampling (catheter, suprapubic puncture) was performed (n = 106, 26.3%). 4 patients were excluded due to equivocal data on urine sampling. VUR rate in children after sterile urine sampling using a catheter or SPA accounted to 31.1%. In those where urine samples acquired by the use of urine bags were used, 33.7% showed VUR on subsequent VCUG (p = 0.718). There were no significant differences as to VUR grades or gender, although VUR was much more commonly diagnosed in female patients (37.0% vs 28.2%, p = 0.227) (Figure). Children diagnosed with their UTI by use of bag urine in our experience carried the same risk of showing a VUR in a subsequent VCUG compared to those, where the initial diagnosis relied - beneath clinical criteria - on urine samples acquired by suprapubic puncture or catheterization. Consequently urine-sampling technique during initial UTI diagnosis alone should not be used as predictor for the reliability of UTI diagnosis and should not influence the further management after UTI. Copyright © 2017 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  3. Basic or extended urine sampling to analyse urine production?

    PubMed

    Denys, Marie-Astrid; Kapila, Vansh; Weiss, Jeffrey; Goessaert, An-Sofie; Everaert, Karel

    2017-09-01

    Frequency volume charts are valuable tools to objectify urine production in patients with nocturia, enuresis or nocturnal incontinence. Analyses of daytime and nighttime urine (=basic collection) or analyses of urine samples collected every 3 h (=extended collection) extend this evaluation by describing circadian patterns of water and solute diuresis (=renal function profiles). To assess intra-individual correlation and agreement between renal function profiles provided using basic and extended urine collections, and using two extended urine collections. To create a short-form of the extended collection. This prospective observational study was executed at Ghent University Hospital, Belgium. Study participation was open for anyone visiting the hospital. Participants collected one basic and two extended 24-h urine collections. Urinary levels of osmolality, sodium and creatinine were determined. There was a moderate to strong correlation between results of basic and extended urinalyses. Comparing both extended urinalyses showed a moderate correlation between the eight individual samples and a weak to strong correlation between the mean daytime and nighttime values of renal functions. Different samples could be considered as most representative for mean daytime values, while all samples collected between 03 and 05am showed the highest agreement with mean nighttime values of renal function. Since there is a good correlation and agreement between basic and extended urine collections to study the mechanisms underlying urine production, the choice of urine sampling method to evaluate urine production depends on the purpose. A nighttime-only urine sample collected between 03 and 05am may be the most practical approach. © 2017 Wiley Periodicals, Inc.

  4. Comparison of vacuum and non-vacuum urine tubes for urinary sediment analysis.

    PubMed

    Topcuoglu, Canan; Sezer, Sevilay; Kosem, Arzu; Ercan, Mujgan; Turhan, Turan

    2017-12-01

    Urine collection systems with aspiration system for vacuum tubes are becoming increasingly common for urinalysis, especially for microscopic examination of the urine. In this study, we aimed to examine whether vacuum aspiration of the urine sample has any adverse effect on sediment analysis by comparing results from vacuum and non-vacuum urine tubes. The study included totally 213 urine samples obtained from inpatients and outpatients in our hospital. Urine samples were collected to containers with aspiration system for vacuum tubes. Each sample was aliquoted to both vacuum and non-vacuum urine tubes. Urinary sediment analysis was performed using manual microscope. Results were evaluated using chi-square test. Comparison of the sediment analysis results from vacuum and non-vacuum urine tubes showed that results were highly concordant for erythrocyte, leukocyte and epithelial cells (gamma values 1, 0.997, and 0.994, respectively; p < .001). Results were also concordant for urinary casts, crystals and yeast (kappa values 0.815, 0.945 and 1, respectively; p < .001). The results show that in urinary sediment analysis, vacuum aspiration has no adverse effect on the cellular components except on casts.

  5. Long-Term Follow-up of HPV Infection Using Urine and Cervical Quantitative HPV DNA Testing

    PubMed Central

    Vorsters, Alex; Van Keer, Severien; Biesmans, Samantha; Hens, Annick; De Coster, Ilse; Goossens, Herman; Ieven, Margareta; Van Damme, Pierre

    2016-01-01

    The link between infection with high-risk human papillomavirus (hrHPV) and cervical cancer has been clearly demonstrated. Virological end-points showing the absence of persistent HPV infection are now accepted as a way of monitoring the impact of prophylactic vaccination programs and therapeutic vaccine trials. This study investigated the use of urine samples, which can be collected by self-sampling at home, instead of cervical samples for follow-up of an HPV intervention trial. Eighteen initially HPV DNA-positive women participating in an HPV therapeutic vaccine trial were monitored during a three-year follow-up period. A total of 172 urine samples and 85 cervical samples were collected. We obtained a paired urine sample for each of the 85 cervical samples by recovering urine samples from six monthly gynaecological examinations. We performed a small pilot study in which the participating women used a urine collection device at home and returned their urine sample to the laboratory by mail. All samples were analyzed using quantitative real-time HPV DNA PCR. A good association (κ value of 0.65) was found between the presence of HPV DNA in urine and a subsequent cervical sample. Comparisons of the number of HPV DNA copies in urine and paired cervical samples revealed a significant Spearman rho of 0.676. This correlation was superior in women with severe lesions. The HPV DNA results of the small pilot study based on self-collected urine samples at home are consistent with previous and subsequent urine and/or cervical results. We demonstrated that urine sampling may be a valid alternative to cervical samples for the follow-up of HPV intervention trials or programs. The potential clinical value of urine viral load monitoring should be further investigated. PMID:27196899

  6. Long-Term Follow-up of HPV Infection Using Urine and Cervical Quantitative HPV DNA Testing.

    PubMed

    Vorsters, Alex; Van Keer, Severien; Biesmans, Samantha; Hens, Annick; De Coster, Ilse; Goossens, Herman; Ieven, Margareta; Van Damme, Pierre

    2016-05-17

    The link between infection with high-risk human papillomavirus (hrHPV) and cervical cancer has been clearly demonstrated. Virological end-points showing the absence of persistent HPV infection are now accepted as a way of monitoring the impact of prophylactic vaccination programs and therapeutic vaccine trials. This study investigated the use of urine samples, which can be collected by self-sampling at home, instead of cervical samples for follow-up of an HPV intervention trial. Eighteen initially HPV DNA-positive women participating in an HPV therapeutic vaccine trial were monitored during a three-year follow-up period. A total of 172 urine samples and 85 cervical samples were collected. We obtained a paired urine sample for each of the 85 cervical samples by recovering urine samples from six monthly gynaecological examinations. We performed a small pilot study in which the participating women used a urine collection device at home and returned their urine sample to the laboratory by mail. All samples were analyzed using quantitative real-time HPV DNA PCR. A good association (κ value of 0.65) was found between the presence of HPV DNA in urine and a subsequent cervical sample. Comparisons of the number of HPV DNA copies in urine and paired cervical samples revealed a significant Spearman rho of 0.676. This correlation was superior in women with severe lesions. The HPV DNA results of the small pilot study based on self-collected urine samples at home are consistent with previous and subsequent urine and/or cervical results. We demonstrated that urine sampling may be a valid alternative to cervical samples for the follow-up of HPV intervention trials or programs. The potential clinical value of urine viral load monitoring should be further investigated.

  7. Effects of diet composition on mutagenic activity in urine.

    PubMed

    Ohara, Akihiro; Matsuhisa, Tsugio

    2004-01-01

    The effects of dietary habits on mutagenic activity in urine were investigated using the umu test based on the use of the genetically engineered bacteria Salmonella typhimurium TA 1535 pSK1002. Genotoxic effects in sample urine were detected by measuring the activation of the SOS response in the bacteria and recording the beta- galactosidase activity. Human subjects consisted of smokers and non-smokers. Urine from subjects who consumed fish showed the highest mutagenic activity, followed by the urine samples from subjects who ate pork or beef. Chicken induced a low level of mutagenic activity. When the subjects ate fried or roasted animal foods, the urine samples gave higher mutagenicity than the urine samples from the subject who consumed non-fried or non-roasted animal foods. When the subject ate vegetables along with a diet rich in animal foods, the activity in urine decreased. Herbs and spices gave the same tendency toward decline as vegetables. Non-smoker urine shower mutagenic activity than samples from smokers.

  8. Comparison of the Abbott RealTime High Risk HPV test and the Roche cobas 4800 HPV test using urine samples.

    PubMed

    Lim, Myong Cheol; Lee, Do-Hoon; Hwang, Sang-Hyun; Hwang, Na Rae; Lee, Bomyee; Shin, Hye Young; Jun, Jae Kwan; Yoo, Chong Woo; Lee, Dong Ock; Seo, Sang-Soo; Park, Sang-Yoon; Joo, Jungnam

    2017-05-01

    Human papillomavirus (HPV) testing based on cervical samples is important for use in cervical cancer screening. However, cervical sampling is invasive. Therefore, non-invasive methods for detecting HPV, such as urine samples, are needed. For HPV detection in urine samples, two real-time PCR (RQ-PCR) tests, Roche cobas 4800 test (Roche_HPV; Roche Molecular Diagnostics) and Abbott RealTime High Risk HPV test (Abbott_HPV; Abbott Laboratories) were compared to standard cervical samples. The performance of Roche_HPV and Abbott_HPV for HPV detection was evaluated at the National Cancer Center using 100 paired cervical and urine samples. The tests were also compared using urine samples stored at various temperatures and for a range of durations. The overall agreement between the Roche_HPV and Abbott_HPV tests using urine samples for any hrHPV type was substantial (86.0% with a kappa value of 0.7173), and that for HPV 16/18 was nearly perfect (99.0% with a kappa value of 0.9668). The relative sensitivities (based on cervical samples) for HPV 16/18 detection using Roche_HPV and Abbott_HPV with urine samples were 79.2% (95% CI; 57.9-92.9%) and 81.8% (95% CI; 59.7-94.8%), respectively. When the cut-off C T value for Abbott_HPV was extended to 40 for urine samples, the relative sensitivity of Abbott_HPV increased to 91.7% from 81.8% for HPV16/18 detection and to 87.0% from 68.5% for other hrHPV detection. The specificity was not affected by the change in the C T threshold. Roche_HPV and Abbott_HPV showed high concordance. However, HPV DNA detection using urine samples was inferior to HPV DNA detection using cervical samples. Interestingly, when the cut-off C T value was set to 40, Abbott_HPV using urine samples showed high sensitivity and specificity, comparable to those obtained using cervical samples. Fully automated DNA extraction and detection systems, such as Roche_HPV and Abbott_HPV, could reduce the variability in HPV detection and accelerate the standardization of HPV detection in urine. Thus, urine samples may be an effective alternative for HPV detection in women who hesitate to participate in cervical cancer screening programs. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Is a pre-analytical process for urinalysis required?

    PubMed

    Petit, Morgane; Beaudeux, Jean-Louis; Majoux, Sandrine; Hennequin, Carole

    2017-10-01

    For the reliable urinary measurement of calcium, phosphate and uric acid, a pre-analytical process by adding acid or base to urine samples at laboratory is recommended in order to dissolve precipitated solutes. Several studies on different kind of samples and analysers have previously shown that a such pre-analytical treatment is useless. The objective was to study the necessity of pre-analytical treatment of urine on samples collected using the V-Monovette ® (Sarstedt) system and measured on the analyser Architect C16000 (Abbott Diagnostics). Sixty urinary samples of hospitalized patients were selected (n=30 for calcium and phosphate, and n=30 for uric acid). After acidification of urine samples for measurement of calcium and phosphate, and alkalinisation for measurement of uric acid respectively, differences between results before and after the pre-analytical treatment were compared to acceptable limits recommended by the French society of clinical biology (SFBC). No difference in concentration between before and after pre-analytical treatment of urine samples exceeded acceptable limits from SFBC for measurement of calcium and uric acid. For phosphate, only one sample exceeded these acceptable limits, showing a result paradoxically lower after acidification. In conclusion, in agreement with previous study, our results show that acidification or alkalinisation of urine samples from 24 h urines or from urination is not a pre-analytical necessity for measurement of calcium, phosphate and uric acid.

  10. Oral fluid vs. Urine Analysis to Monitor Synthetic Cannabinoids and Classic Drugs Recent Exposure

    PubMed Central

    Blandino, Vincent; Wetzel, Jillian; Kim, Jiyoung; Haxhi, Petrit; Curtis, Richard; Concheiro, Marta

    2018-01-01

    Background Urine is a common biological sample to monitor recent drug exposure, and oral fluid is an alternative matrix of increasing interest in clinical and forensic toxicology. Limited data are available about oral fluid vs. urine drug disposition, especially for synthetic cannabinoids. Objective To compare urine and oral fluid as biological matrices to monitor recent drug exposure among HIV-infected homeless individuals. Methods Seventy matched urine and oral fluid samples were collected from 13 participants. Cannabis, amphetamines, benzodiazepines, cocaine and opiates were analyzed in urine by the enzyme-multiplied-immunoassay-technique and in oral fluid by liquid chromatography tandem mass spectrometry (LC-MSMS). Eleven synthetic cannabinoids were analyzed in urine and in oral fluid by LC-MSMS. Results Five oral fluid samples were positive for AB-FUBINACA. In urine, 4 samples tested positive for synthetic cannabinoids PB-22, 5-Fluoro-PB-22, AB-FUBINACA, and metabolites UR-144 5-pentanoic acid and UR-144 4-hydroxypentyl. In only one case, oral fluid and urine results matched, both specimens being AB-FUBINACA positive. For cannabis, 40 samples tested positive in urine and 30 in oral fluid (85.7% match). For cocaine, 37 urine and 52 oral fluid samples were positive (75.7% match). Twenty-four urine samples were positive for opiates, and 25 in oral fluid (81.4% match). For benzodiazepines, 23 samples were positive in urine and 25 in oral fluid (85.7% match). Conclusion/Discussion These results offer new information about drugs disposition between urine and oral fluid. Oral fluid is a good alternative matrix to urine for monitoring cannabis, cocaine, opiates and benzodiazepines recent use; however, synthetic cannabinoids showed mixed results. PMID:29173162

  11. Oral Fluid vs. Urine Analysis to Monitor Synthetic Cannabinoids and Classic Drugs Recent Exposure.

    PubMed

    Blandino, Vincent; Wetzel, Jillian; Kim, Jiyoung; Haxhi, Petrit; Curtis, Richard; Concheiro, Marta

    2017-01-01

    Urine is a common biological sample to monitor recent drug exposure, and oral fluid is an alternative matrix of increasing interest in clinical and forensic toxicology. Limited data are available about oral fluid vs. urine drug disposition, especially for synthetic cannabinoids. To compare urine and oral fluid as biological matrices to monitor recent drug exposure among HIV-infected homeless individuals. Seventy matched urine and oral fluid samples were collected from 13 participants. Cannabis, amphetamines, benzodiazepines, cocaine and opiates were analyzed in urine by the enzyme-multipliedimmunoassay- technique and in oral fluid by liquid chromatography tandem mass spectrometry (LCMSMS). Eleven synthetic cannabinoids were analyzed in urine and in oral fluid by LC-MSMS. Five oral fluid samples were positive for AB-FUBINACA. In urine, 4 samples tested positive for synthetic cannabinoids PB-22, 5-Fluoro-PB-22, AB-FUBINACA, and metabolites UR-144 5-pentanoic acid and UR-144 4-hydroxypentyl. In only one case, oral fluid and urine results matched, both specimens being AB-FUBINACA positive. For cannabis, 40 samples tested positive in urine and 30 in oral fluid (85.7% match). For cocaine, 37 urine and 52 oral fluid samples were positive (75.7% match). Twenty-four urine samples were positive for opiates, and 25 in oral fluid (81.4% match). For benzodiazepines, 23 samples were positive in urine and 25 in oral fluid (85.7% match). These results offer new information about drugs disposition between urine and oral fluid. Oral fluid is a good alternative matrix to urine for monitoring cannabis, cocaine, opiates and benzodiazepines recent use; however, synthetic cannabinoids showed mixed results. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  12. Mutagens in urine of non-smoking and smoking workers in an aircraft tyre retreading plant. Skin exposure as a causal factor?

    PubMed

    Bos, R P; Kromhout, H; Ikink, H; de Haan, W; Koppejan, J; Theuws, J L

    1989-05-01

    In an aircraft type retreading plant environmental samples taken at several departments showed mutagenic properties. Thursday urine samples of non-smoking and smoking workers showed higher urinary mutagenicity than urine samples collected on Sundays, thus suggesting occupational exposure to mutagenic substances. A relation between urinary mutagenicity on Thursdays and skin contamination measured on Wednesdays was observed. The data suggest that intake through the skin plays an important role in the occupational exposure to mutagenic compounds of rubber workers.

  13. Optimization of HPV DNA detection in urine by improving collection, storage, and extraction.

    PubMed

    Vorsters, A; Van den Bergh, J; Micalessi, I; Biesmans, S; Bogers, J; Hens, A; De Coster, I; Ieven, M; Van Damme, P

    2014-11-01

    The benefits of using urine for the detection of human papillomavirus (HPV) DNA have been evaluated in disease surveillance, epidemiological studies, and screening for cervical cancers in specific subgroups. HPV DNA testing in urine is being considered for important purposes, notably the monitoring of HPV vaccination in adolescent girls and young women who do not wish to have a vaginal examination. The need to optimize and standardize sampling, storage, and processing has been reported.In this paper, we examined the impact of a DNA-conservation buffer, the extraction method, and urine sampling on the detection of HPV DNA and human DNA in urine provided by 44 women with a cytologically normal but HPV DNA-positive cervical sample. Ten women provided first-void and midstream urine samples. DNA analysis was performed using real-time PCR to allow quantification of HPV and human DNA.The results showed that an optimized method for HPV DNA detection in urine should (a) prevent DNA degradation during extraction and storage, (b) recover cell-free HPV DNA in addition to cell-associated DNA, (c) process a sufficient volume of urine, and (d) use a first-void sample.In addition, we found that detectable human DNA in urine may not be a good internal control for sample validity. HPV prevalence data that are based on urine samples collected, stored, and/or processed under suboptimal conditions may underestimate infection rates.

  14. Comparison of initial stream urine samples and cervical samples for detection of human papillomavirus.

    PubMed

    Hagihara, Mao; Yamagishi, Yuka; Izumi, Koji; Miyazaki, Narimi; Suzuki, Takayoshi; Kato, Hideo; Nishiyama, Naoya; Koizumi, Yusuke; Suematsu, Hiroyuki; Mikamo, Hiroshige

    2016-08-01

    Uterine cervical cancer is a treatable and preventable cancer. Medical efforts to reduce rates of cervical cancer focus on the promotion of human papillomavirus (HPV) vaccination and the promotion of routine cervical cancer screening done by cervical cytology and cervical HPV testing. Urine-based HPV testing would be simple and noninvasive approach to screen for cervical cancer. Two biospecimens (clinician-taken sample from cervix and initial stream urine sample) were provided from a total of 240 healthy women attending for cancer screening provided for HPV testing. We have assessed the HPV detection rates among cervical samples and pellet fraction of urine samples using HPV test (Anyplex™ II HPV28 Detection kit, Seegene, Korea). Among 240 samples screened, HPV prevalence was 42.9% in pellet fractions of urine samples. The agreement between the two kinds of samples was 98.4%, k = 0.792. Discordant results were observed in 27 cases; 5 were positive only by urine samples and 22 were positive only by smear samples. Sensitivity and specificity for all HPV DNA in pellet fractions of urine using cervical samples as reference was 68.4% and 99.9%. Comparing methodologies of collection of samples for HPV detection, they showed the higher agreements for almost genotypes between cervical samples and pellet fractions of urine samples. These results suggest that urine could be a good noninvasive tool to monitor HPV infection in women. Additional research in a larger and general screening population would be needed. Copyright © 2016 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  15. Evaluation of the BD Vacutainer Plus Urine C&S Preservative Tubes compared with nonpreservative urine samples stored at 4°C and room temperature.

    PubMed

    Eisinger, Stephen W; Schwartz, Matthew; Dam, Lisa; Riedel, Stefan

    2013-09-01

    The stability of urine specimens submitted for culture remains a challenge for many laboratories because of delays in specimen transport. We evaluated the usefulness of BD Vacutainer Plus Urine C&S Preservative Tube in ensuring specimen stability. Clinical urine specimens collected in sterile collection cups (n = 110) were plated onto sheep blood and MacConkey agar following standard laboratory procedures guidelines. Thereafter, specimens were divided into 3 storage conditions: nonpreservative, refrigerated; nonpreservative, room temperature (RT); BD Vacutainer Plus Urine C&S Preservative Tube, RT. For each sample type, additional cultures were set up at 2, 4, 24, and 48 hours. Initially, 18 specimens had no growth, 32 showed mixed skin flora, and 60 yielded at least 1 uropathogen. Increased colony counts of uropathogens were observed for nonpreserved urine samples stored at RT; these changes were statistically significant. Minor differences between refrigerated urine samples and BD Vacutainer Plus Urine C&S Preservative Tube samples were seen but were not statistically significant. The use of preservative-containing collection tubes is desirable to ensure specimen stability when prompt processing or refrigeration is not feasible.

  16. The resident microflora of voided midstream urine of healthy controls: standard versus expanded urine culture protocols.

    PubMed

    Coorevits, L; Heytens, S; Boelens, J; Claeys, G

    2017-04-01

    The workup and interpretation of urine cultures is not always clear-cut, especially for midstream samples contaminated with commensals. Standard urine culture (SUC) protocols are designed in favor of growth of uropathogens at the expense of commensals. In selected clinical situations, however, it is essential to trace fastidious or new uropathogens by expanding the urine culture conditions (EUC). The aim of our study was to map the microflora in midstream urine specimens from healthy controls by means of EUC, in view of the interpretation of bacterial culture results in symptomatic patients. Midstream urine specimens from 101 healthy controls (86 females and 15 males) were examined using both SUC and EUC. Whilst 73 % of samples examined by SUC showed no growth at 10 3  colony-forming units (CFU)/mL, 91 % of samples examined by EUC grew bacterial species in large numbers (≥10 4  CFU/mL). Asymptomatic bacteriuria, as defined by the European guidelines for urinalysis, was detected in six samples with both protocols. EUC revealed 98 different species, mostly Lactobacillus, Staphylococcus, Streptococcus, and Corynebacterium. None of the samples grew Staphylococcus saprophyticus, Corynebacterium urealyticum, or Aerococcus urinae. Samples from females contained higher bacterial loads and showed higher bacterial diversity compared to males. Midstream urine of healthy controls contains large communities of living bacteria that comprise a resident microflora, only revealed by EUC. Hence, the use of EUC instead of SUC in a routine setting would result in more sensitive but less specific results, requiring critical interpretation. In our view, EUC should be reserved for limited indications.

  17. Preparation of magnetic ODS-PAN thin-films for microextraction of quetiapine and clozapine in plasma and urine samples followed by HPLC-UV detection.

    PubMed

    Li, Dan; Zou, Juan; Cai, Pei-Shan; Xiong, Chao-Mei; Ruan, Jin-Lan

    2016-06-05

    In this study, conventional thin-film microextraction (TFME) was endowed with magnetic by introducing superparamagnetic SiO2@Fe3O4 nanoparticles in thin-films. Novel magnetic octadecylsilane (ODS)-polyacrylonitrile (PAN) thin-films were prepared by spraying, and used for the microextraction of quetiapine and clozapine in plasma and urine samples, followed by the detection of HPLC-UV. The influencing factors on the extraction efficiency of magnetic ODS-PAN TFME, including pH, extraction time, desorption solvent, desorption time, and ion strength were investigated systematically. Under the optimal conditions, both analytes showed good linearity over ranges of 0.070-9.000μgmL(-1) and 0.012-9.000μgmL(-1) in plasma and urine samples, respectively, with correlation coefficients (R(2)) above 0.9990. Limits of detection (LODs) for quetiapine in plasma and urine samples were 0.013 and 0.003μgmL(-1), respectively. LODs for clozapine in plasma and urine samples were 0.015 and 0.003μgmL(-1), respectively. The relative standard deviations (RSDs) for quetiapine and clozapine were less than 9.23%. After the validation, the protocol was successfully applied for the determination of quetiapine and clozapine in patients' plasma and urine samples with satisfactory recoveries between 99-110%. The proposed magnetic ODS-PAN TFME was very simple, fast and easy to handle. It showed high potential as a powerful pretreatment technology for routine therapeutic drug monitoring (TDM) in plasma and urine samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Comparison of Depletion Strategies for the Enrichment of Low-Abundance Proteins in Urine.

    PubMed

    Filip, Szymon; Vougas, Konstantinos; Zoidakis, Jerome; Latosinska, Agnieszka; Mullen, William; Spasovski, Goce; Mischak, Harald; Vlahou, Antonia; Jankowski, Joachim

    2015-01-01

    Proteome analysis of complex biological samples for biomarker identification remains challenging, among others due to the extended range of protein concentrations. High-abundance proteins like albumin or IgG of plasma and urine, may interfere with the detection of potential disease biomarkers. Currently, several options are available for the depletion of abundant proteins in plasma. However, the applicability of these methods in urine has not been thoroughly investigated. In this study, we compared different, commercially available immunodepletion and ion-exchange based approaches on urine samples from both healthy subjects and CKD patients, for their reproducibility and efficiency in protein depletion. A starting urine volume of 500 μL was used to simulate conditions of a multi-institutional biomarker discovery study. All depletion approaches showed satisfactory reproducibility (n=5) in protein identification as well as protein abundance. Comparison of the depletion efficiency between the unfractionated and fractionated samples and the different depletion strategies, showed efficient depletion in all cases, with the exception of the ion-exchange kit. The depletion efficiency was found slightly higher in normal than in CKD samples and normal samples yielded more protein identifications than CKD samples when using both initial as well as corresponding depleted fractions. Along these lines, decrease in the amount of albumin and other targets as applicable, following depletion, was observed. Nevertheless, these depletion strategies did not yield a higher number of identifications in neither the urine from normal nor CKD patients. Collectively, when analyzing urine in the context of CKD biomarker identification, no added value of depletion strategies can be observed and analysis of unfractionated starting urine appears to be preferable.

  19. Comparison of Depletion Strategies for the Enrichment of Low-Abundance Proteins in Urine

    PubMed Central

    Filip, Szymon; Vougas, Konstantinos; Zoidakis, Jerome; Latosinska, Agnieszka; Mullen, William; Spasovski, Goce; Mischak, Harald; Vlahou, Antonia; Jankowski, Joachim

    2015-01-01

    Proteome analysis of complex biological samples for biomarker identification remains challenging, among others due to the extended range of protein concentrations. High-abundance proteins like albumin or IgG of plasma and urine, may interfere with the detection of potential disease biomarkers. Currently, several options are available for the depletion of abundant proteins in plasma. However, the applicability of these methods in urine has not been thoroughly investigated. In this study, we compared different, commercially available immunodepletion and ion-exchange based approaches on urine samples from both healthy subjects and CKD patients, for their reproducibility and efficiency in protein depletion. A starting urine volume of 500 μL was used to simulate conditions of a multi-institutional biomarker discovery study. All depletion approaches showed satisfactory reproducibility (n=5) in protein identification as well as protein abundance. Comparison of the depletion efficiency between the unfractionated and fractionated samples and the different depletion strategies, showed efficient depletion in all cases, with the exception of the ion-exchange kit. The depletion efficiency was found slightly higher in normal than in CKD samples and normal samples yielded more protein identifications than CKD samples when using both initial as well as corresponding depleted fractions. Along these lines, decrease in the amount of albumin and other targets as applicable, following depletion, was observed. Nevertheless, these depletion strategies did not yield a higher number of identifications in neither the urine from normal nor CKD patients. Collectively, when analyzing urine in the context of CKD biomarker identification, no added value of depletion strategies can be observed and analysis of unfractionated starting urine appears to be preferable. PMID:26208298

  20. Quantitative analysis of zopiclone, N-desmethylzopiclone, zopiclone N-oxide and 2-amino-5-chloropyridine in urine using LC-MS-MS.

    PubMed

    Nilsson, Gunnel H; Kugelberg, Fredrik C; Ahlner, Johan; Kronstrand, Robert

    2014-01-01

    A simple liquid chromatography-tandem mass spectrometry method was validated to allow determination of zopiclone (ZOP), N-desmethylzopiclone (NDZOP), zopiclone N-oxide (ZOPNO) and 2-amino-5-chloropyridine (ACP) in urine at concentrations up to 3,000 ng/mL within 3.5 min. This method was used for quantitative analysis of the analytes in authentic urine samples obtained 10 h after oral administration of zopiclone (Imovane(®)) and in aliquots of the same urine samples after different storage conditions. In addition, pH of each studied urine sample was measured over time. The results showed that formation of ACP occurred at elevated pH and/or temperature by degradation of ZOP, NDZOP and ZOPNO. This method was also applied to samples obtained from two female victims of drug-facilitated assault. One sample had been exposed to long-term storage conditions at different temperatures and at pH >8.2, which resulted in high concentrations of ACP. The other sample, which was exposed to pH <6.5, showed no formation of ACP. ACP is formed both from ZOP and from its metabolites NDZOP and ZOPNO depending on the pH of the urine, time of storage and/or the temperature conditions. For correct interpretation in forensic cases, ZOP, its major metabolites and ACP should be analyzed. When ACP is identified in urine, the concentrations of ZOP, NDZOP and ZOPNO should be interpreted with great caution. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. The Urine Preservative Acetic Acid Degrades Urine Protein: Implications for Urine Biorepositories and the AASK Cohort Study

    PubMed Central

    Almaani, Salem; Hebert, Lee A.; Rovin, Brad H.

    2017-01-01

    Patients enrolled in the African American Study of Kidney Disease and Hypertension (AASK) Cohort Study who exhibited overt proteinuria have been reported to show high nonalbumin proteinuria (NAP), which is characteristic of a tubulopathy. To determine whether African American Study of Kidney Disease and Hypertension nephropathy (AASK-N) is a tubulopathy, we obtained urine samples of 37 patients with AASK-N, with 24-hour protein-to-creatinine ratios (milligrams per milligram) ranging from 0.2 to 1.0, from the National Institute of Diabetes and Digestive Kidney Diseases repository and tested for seven markers of tubular proteinuria. By protocol, each sample had been collected in acetic acid (0.5%; mean final concentration). Compared with samples from patients with lupus nephritis or healthy black controls, AASK-N samples had lower amounts of six markers. Four markers (albumin, β-2-microglobulin, cystatin C, and osteopontin) were undetectable in most AASK-N samples. Examination by SDS-PAGE followed by protein staining revealed protein profiles indicative of severe protein degradation in 34 of 37 AASK-N urine samples. Treatment of lupus nephritis urine samples with 0.5% acetic acid produced the same protein degradation profile as that of AASK-N urine. We conclude that the increased NAP in AASK-N is an artifact of acetic acid–mediated degradation of albumin. The AASK-N repository urine samples have been compromised by the acetic acid preservative. PMID:28104821

  2. The Urine Preservative Acetic Acid Degrades Urine Protein: Implications for Urine Biorepositories and the AASK Cohort Study.

    PubMed

    Almaani, Salem; Hebert, Lee A; Rovin, Brad H; Birmingham, Daniel J

    2017-05-01

    Patients enrolled in the African American Study of Kidney Disease and Hypertension (AASK) Cohort Study who exhibited overt proteinuria have been reported to show high nonalbumin proteinuria (NAP), which is characteristic of a tubulopathy. To determine whether African American Study of Kidney Disease and Hypertension nephropathy (AASK-N) is a tubulopathy, we obtained urine samples of 37 patients with AASK-N, with 24-hour protein-to-creatinine ratios (milligrams per milligram) ranging from 0.2 to 1.0, from the National Institute of Diabetes and Digestive Kidney Diseases repository and tested for seven markers of tubular proteinuria. By protocol, each sample had been collected in acetic acid (0.5%; mean final concentration). Compared with samples from patients with lupus nephritis or healthy black controls, AASK-N samples had lower amounts of six markers. Four markers (albumin, β -2-microglobulin, cystatin C, and osteopontin) were undetectable in most AASK-N samples. Examination by SDS-PAGE followed by protein staining revealed protein profiles indicative of severe protein degradation in 34 of 37 AASK-N urine samples. Treatment of lupus nephritis urine samples with 0.5% acetic acid produced the same protein degradation profile as that of AASK-N urine. We conclude that the increased NAP in AASK-N is an artifact of acetic acid-mediated degradation of albumin. The AASK-N repository urine samples have been compromised by the acetic acid preservative. Copyright © 2017 by the American Society of Nephrology.

  3. Reproducibility of urinary biomarkers in multiple 24-h urine samples.

    PubMed

    Sun, Qi; Bertrand, Kimberly A; Franke, Adrian A; Rosner, Bernard; Curhan, Gary C; Willett, Walter C

    2017-01-01

    Limited knowledge regarding the reproducibility of biomarkers in 24-h urine samples has hindered the collection and use of the samples in epidemiologic studies. We aimed to evaluate the reproducibility of various markers in repeat 24-h urine samples. We calculated intraclass correlation coefficients (ICCs) of biomarkers measured in 24-h urine samples that were collected in 3168 participants in the NHS (Nurses' Health Study), NHSII (Nurses' Health Study II), and Health Professionals Follow-Up Study. In 742 women with 4 samples each collected over the course of 1 y, ICCs for sodium were 0.32 in the NHS and 0.34 in the NHSII. In 2439 men and women with 2 samples each collected over 1 wk to ≥1 mo, the ICCs ranged from 0.33 to 0.68 for sodium at various intervals between collections. The urinary excretion of potassium, calcium, magnesium, phosphate, sulfate, and other urinary markers showed generally higher reproducibility (ICCs >0.4). In 47 women with two 24-h urine samples, ICCs ranged from 0.15 (catechin) to 0.75 (enterolactone) for polyphenol metabolites. For phthalates, ICCs were generally ≤0.26 except for monobenzyl phthalate (ICC: 0.55), whereas the ICC was 0.39 for bisphenol A (BPA). We further estimated that, for the large majority of the biomarkers, the mean of three 24-h urine samples could provide a correlation of ≥0.8 with true long-term urinary excretion. These data suggest that the urinary excretion of various biomarkers, such as minerals, electrolytes, most polyphenols, and BPA, is reasonably reproducible in 24-h urine samples that are collected within a few days or ≤1 y. Our findings show that three 24-h samples are sufficient for the measurement of long-term exposure status in epidemiologic studies. © 2017 American Society for Nutrition.

  4. Reproducibility of urinary biomarkers in multiple 24-h urine samples123

    PubMed Central

    Sun, Qi; Bertrand, Kimberly A; Franke, Adrian A; Rosner, Bernard; Curhan, Gary C; Willett, Walter C

    2017-01-01

    Background: Limited knowledge regarding the reproducibility of biomarkers in 24-h urine samples has hindered the collection and use of the samples in epidemiologic studies. Objective: We aimed to evaluate the reproducibility of various markers in repeat 24-h urine samples. Design: We calculated intraclass correlation coefficients (ICCs) of biomarkers measured in 24-h urine samples that were collected in 3168 participants in the NHS (Nurses’ Health Study), NHSII (Nurses’ Health Study II), and Health Professionals Follow-Up Study. Results: In 742 women with 4 samples each collected over the course of 1 y, ICCs for sodium were 0.32 in the NHS and 0.34 in the NHSII. In 2439 men and women with 2 samples each collected over 1 wk to ≥1 mo, the ICCs ranged from 0.33 to 0.68 for sodium at various intervals between collections. The urinary excretion of potassium, calcium, magnesium, phosphate, sulfate, and other urinary markers showed generally higher reproducibility (ICCs >0.4). In 47 women with two 24-h urine samples, ICCs ranged from 0.15 (catechin) to 0.75 (enterolactone) for polyphenol metabolites. For phthalates, ICCs were generally ≤0.26 except for monobenzyl phthalate (ICC: 0.55), whereas the ICC was 0.39 for bisphenol A (BPA). We further estimated that, for the large majority of the biomarkers, the mean of three 24-h urine samples could provide a correlation of ≥0.8 with true long-term urinary excretion. Conclusions: These data suggest that the urinary excretion of various biomarkers, such as minerals, electrolytes, most polyphenols, and BPA, is reasonably reproducible in 24-h urine samples that are collected within a few days or ≤1 y. Our findings show that three 24-h samples are sufficient for the measurement of long-term exposure status in epidemiologic studies. PMID:28049663

  5. Urine chromium as an estimator of air exposure to stainless steel welding fumes.

    PubMed

    Sjögren, B; Hedström, L; Ulfvarson, U

    1983-01-01

    Welding stainless steel with covered electrodes, also called manual metal arc welding, generates hexavalent airborne chromium. Chromium concentrations in air and post-shift urine samples, collected the same arbitrarily chosen working day, showed a linear relationship. Since post-shift urine samples reflect chromium concentrations of both current and previous stainless steel welding fume exposure, individual urine measurements are suggested as approximate although not exact estimators of current exposure. This study evaluates the practical importance of such measurements by means of confidence limits and tests of validity.

  6. Albumin adsorption onto surfaces of urine collection and analysis containers☆

    PubMed Central

    Robinson, Mary K.; Caudill, Samuel P.; Koch, David D.; Ritchie, James; Hortin, Glen; Eckfeldt, John H.; Sandberg, Sverre; Williams, Desmond; Myers, Gary; Miller, W. Greg

    2017-01-01

    Background Adsorption of albumin onto urine collection and analysis containers may cause falsely low concentrations. Methods We added 125I-labeled human serum albumin to urine and to phosphate buffered solutions, incubated them with 22 plastic container materials and measured adsorption by liquid scintillation counting. Results Adsorption of urine albumin (UA) at 5–6 mg/l was <0.9%; and at 90 mg/l was <0.4%. Adsorption was generally less at pH 8 than pH 5 but only 3 cases had p <0.05. Adsorption from 11 unaltered urine samples with albumin 5–333 mg/l was <0.8%. Albumin adsorption for the material with greatest binding was extrapolated to the surface areas of 100 ml and 2 l collection containers, and to instrument sample cups and showed <1% change in concentration at 5 mg/l and <0.5% change at 20 mg/l or higher concentrations. Adsorption of albumin from phosphate buffered solutions (2–28%) was larger than that from urine. Conclusions Albumin adsorption differed among urine samples and plastic materials, but the total influence of adsorption was <1% for all materials and urine samples tested. Adsorption of albumin from phosphate buffered solutions was larger than that from urine and could be a limitation for preparations used as calibrators. PMID:24513540

  7. Albumin adsorption onto surfaces of urine collection and analysis containers.

    PubMed

    Robinson, Mary K; Caudill, Samuel P; Koch, David D; Ritchie, James; Hortin, Glen; Eckfeldt, John H; Sandberg, Sverre; Williams, Desmond; Myers, Gary; Miller, W Greg

    2014-04-20

    Adsorption of albumin onto urine collection and analysis containers may cause falsely low concentrations. We added (125)I-labeled human serum albumin to urine and to phosphate buffered solutions, incubated them with 22 plastic container materials and measured adsorption by liquid scintillation counting. Adsorption of urine albumin (UA) at 5-6 mg/l was <0.9%; and at 90 mg/l was <0.4%. Adsorption was generally less at pH8 than pH5 but only 3 cases had p<0.05. Adsorption from 11 unaltered urine samples with albumin 5-333 mg/l was <0.8%. Albumin adsorption for the material with greatest binding was extrapolated to the surface areas of 100 ml and 2l collection containers, and to instrument sample cups and showed <1% change in concentration at 5 mg/l and <0.5% change at 20 mg/l or higher concentrations. Adsorption of albumin from phosphate buffered solutions (2-28%) was larger than that from urine. Albumin adsorption differed among urine samples and plastic materials, but the total influence of adsorption was <1% for all materials and urine samples tested. Adsorption of albumin from phosphate buffered solutions was larger than that from urine and could be a limitation for preparations used as calibrators. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Detection and genotyping of HPV in urine samples from Chilean women attending primary health care centers.

    PubMed

    Vergara, Nicolás; Balanda, Monserrat; Hidalgo, Wilma; Martín, Héctor San; Aceituno, Alexis; Roldán, Francisco; Villalón, Tania; Hott, Melissa; Espinoza, Gloria; Quiero, Andrea; Valenzuela, María T; Ramírez, Eugenio

    2018-04-01

    Cervical cancer is the second most common malignant neoplasm in women worldwide representing approximately 10% of all types of cancers. Triage of women through cervical cytology has been an important strategy for the surveillance and control of new cases of cervical cancer. However, in many regions around the world cervical cytology has a low coverage compared to developed countries. The molecular detection of HPV is the most effective method to increase the screening sensitivity of women at risk of developing cervical cancer. There are very few studies about the efficacy of urine testing for detection of HPV in women followed up in primary health care centers. Consequently, the efficacy of using urine HPV screening in these populations has not been addressed yet. Here, we compared the detection of HPV in simultaneous urine and cervical samples of women followed up in primary health care centers. Urine and cervical samples were analyzed in 543 women attending at primary health care centers. HPV was detected by real time PCR, and HPV typing performed by PCR-RLB. A general HPV concordance of 86.2% (κ = 0.72) was determined between urine and cervical samples. The concordance for HPV-16 and 18 was almost perfect (κ = 0.82) and strong (κ = 0.77), respectively. The sensitivity and specificity for all HPV genotypes in urine using cervical samples as reference were 82.1 and 93.7%, respectively. The results showed that urine is a good alternative as clinical sample for HPV screening in women attending primary health care centers. Therefore, urine should be used as an alternative sample for increasing triage coverage either in refractory women participating in Pap surveillance programs or when cervical samples are not available.

  9. Sample preparation and storage can change arsenic speciation in human urine.

    PubMed

    Feldmann, J; Lai, V W; Cullen, W R; Ma, M; Lu, X; Le, X C

    1999-11-01

    Stability of chemical speciation during sample handling and storage is a prerequisite to obtaining reliable results of trace element speciation analysis. There is no comprehensive information on the stability of common arsenic species, such as inorganic arsenite [As(III)], arsenate [As(V)], monomethylarsonic acid, dimethylarsinic acid, and arsenobetaine, in human urine. We compared the effects of the following storage conditions on the stability of these arsenic species: temperature (25, 4, and -20 degrees C), storage time (1, 2, 4, and 8 months), and the use of additives (HCl, sodium azide, benzoic acid, benzyltrimethylammonium chloride, and cetylpyridinium chloride). HPLC with both inductively coupled plasma mass spectrometry and hydride generation atomic fluorescence detection techniques were used for the speciation of arsenic. We found that all five of the arsenic species were stable for up to 2 months when urine samples were stored at 4 and -20 degrees C without any additives. For longer period of storage (4 and 8 months), the stability of arsenic species was dependent on urine matrices. Whereas the arsenic speciation in some urine samples was stable for the entire 8 months at both 4 and -20 degrees C, other urine samples stored under identical conditions showed substantial changes in the concentration of As(III), As(V), monomethylarsonic acid, and dimethylarsinic acid. The use of additives did not improve the stability of arsenic speciation in urine. The addition of 0.1 mol/L HCl (final concentration) to urine samples produced relative changes in inorganic As(III) and As(V) concentrations. Low temperature (4 and -20 degrees C) conditions are suitable for the storage of urine samples for up to 2 months. Untreated samples maintain their concentration of arsenic species, and additives have no particular benefit. Strong acidification is not appropriate for speciation analysis.

  10. Estimating mean change in population salt intake using spot urine samples.

    PubMed

    Petersen, Kristina S; Wu, Jason H Y; Webster, Jacqui; Grimes, Carley; Woodward, Mark; Nowson, Caryl A; Neal, Bruce

    2017-10-01

    Spot urine samples are easier to collect than 24-h urine samples and have been used with estimating equations to derive the mean daily salt intake of a population. Whether equations using data from spot urine samples can also be used to estimate change in mean daily population salt intake over time is unknown. We compared estimates of change in mean daily population salt intake based upon 24-h urine collections with estimates derived using equations based on spot urine samples. Paired and unpaired 24-h urine samples and spot urine samples were collected from individuals in two Australian populations, in 2011 and 2014. Estimates of change in daily mean population salt intake between 2011 and 2014 were obtained directly from the 24-h urine samples and by applying established estimating equations (Kawasaki, Tanaka, Mage, Toft, INTERSALT) to the data from spot urine samples. Differences between 2011 and 2014 were calculated using mixed models. A total of 1000 participants provided a 24-h urine sample and a spot urine sample in 2011, and 1012 did so in 2014 (paired samples n = 870; unpaired samples n = 1142). The participants were community-dwelling individuals living in the State of Victoria or the town of Lithgow in the State of New South Wales, Australia, with a mean age of 55 years in 2011. The mean (95% confidence interval) difference in population salt intake between 2011 and 2014 determined from the 24-h urine samples was -0.48g/day (-0.74 to -0.21; P < 0.001). The corresponding result estimated from the spot urine samples was -0.24 g/day (-0.42 to -0.06; P = 0.01) using the Tanaka equation, -0.42 g/day (-0.70 to -0.13; p = 0.004) using the Kawasaki equation, -0.51 g/day (-1.00 to -0.01; P = 0.046) using the Mage equation, -0.26 g/day (-0.42 to -0.10; P = 0.001) using the Toft equation, -0.20 g/day (-0.32 to -0.09; P = 0.001) using the INTERSALT equation and -0.27 g/day (-0.39 to -0.15; P < 0.001) using the INTERSALT equation with potassium. There was no evidence that the changes detected by the 24-h collections and estimating equations were different (all P > 0.058). Separate analysis of the unpaired and paired data showed that detection of change by the estimating equations was observed only in the paired data. All the estimating equations based upon spot urine samples identified a similar change in daily salt intake to that detected by the 24-h urine samples. Methods based upon spot urine samples may provide an approach to measuring change in mean population salt intake, although further investigation in larger and more diverse population groups is required. © The Author 2016; all rights reserved. Published by Oxford University Press on behalf of the International Epidemiological Association

  11. Influence of storage conditions on aluminum concentrations in serum, dialysis fluid, urine, and tap water.

    PubMed

    Wilhelm, M; Ohnesorge, F K

    1990-01-01

    The influence of storage temperature, vessel type, and treatment on alterations of aluminum (Al) concentrations in serum, urine, and dialysis fluid samples was studied at three different concentrations for each sample over an 18-month period. Furthermore, the influence of acidification on Al levels in tap water, urine, and dialysis fluid samples was studied over a four-month period. Al was measured by atomic absorption spectrometry. Sample storage in glass vessels was unsuitable, whereas only minor alterations of Al levels were observed with storage in polypropylene tubes, polystyrene tubes, and Monovettes. By using appropriate plastic containers, acid washing of the vessels showed no improvement. Frozen storage was superior compared with 4 degrees C, whereas storage at -80 degrees C offered no advantage compared with storage at -20 degrees C. Acidification of tap water samples was necessary to stabilize Al levels during storage. No striking effect of acidification on Al levels in urine and dialysis fluid samples was found. It is concluded that longterm storage of serum, urine, tap water, and dialysis fluid samples is possible if appropriate conditions are used.

  12. Optimization of analytical and pre-analytical conditions for MALDI-TOF-MS human urine protein profiles.

    PubMed

    Calvano, C D; Aresta, A; Iacovone, M; De Benedetto, G E; Zambonin, C G; Battaglia, M; Ditonno, P; Rutigliano, M; Bettocchi, C

    2010-03-11

    Protein analysis in biological fluids, such as urine, by means of mass spectrometry (MS) still suffers for insufficient standardization in protocols for sample collection, storage and preparation. In this work, the influence of these variables on healthy donors human urine protein profiling performed by matrix assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS) was studied. A screening of various urine sample pre-treatment procedures and different sample deposition approaches on the MALDI target was performed. The influence of urine samples storage time and temperature on spectral profiles was evaluated by means of principal component analysis (PCA). The whole optimized procedure was eventually applied to the MALDI-TOF-MS analysis of human urine samples taken from prostate cancer patients. The best results in terms of detected ions number and abundance in the MS spectra were obtained by using home-made microcolumns packed with hydrophilic-lipophilic balance (HLB) resin as sample pre-treatment method; this procedure was also less expensive and suitable for high throughput analyses. Afterwards, the spin coating approach for sample deposition on the MALDI target plate was optimized, obtaining homogenous and reproducible spots. Then, PCA indicated that low storage temperatures of acidified and centrifuged samples, together with short handling time, allowed to obtain reproducible profiles without artifacts contribution due to experimental conditions. Finally, interesting differences were found by comparing the MALDI-TOF-MS protein profiles of pooled urine samples of healthy donors and prostate cancer patients. The results showed that analytical and pre-analytical variables are crucial for the success of urine analysis, to obtain meaningful and reproducible data, even if the intra-patient variability is very difficult to avoid. It has been proven how pooled urine samples can be an interesting way to make easier the comparison between healthy and pathological samples and to individuate possible differences in the protein expression between the two sets of samples. Copyright 2009 Elsevier B.V. All rights reserved.

  13. A needle extraction utilizing a molecularly imprinted-sol-gel xerogel for on-line microextraction of the lung cancer biomarker bilirubin from plasma and urine samples.

    PubMed

    Moein, Mohammad Mahdi; Jabbar, Dunia; Colmsjö, Anders; Abdel-Rehim, Mohamed

    2014-10-31

    In the present work, a needle trap utilizing a molecularly imprinted sol-gel xerogel was prepared for the on-line microextraction of bilirubin from plasma and urine samples. Each prepared needle could be used for approximately one hundred extractions before it was discarded. Imprinted and non-imprinted sol-gel xerogel were applied for the extraction of bilirubin from plasma and urine samples. The produced molecularly imprinted sol-gel xerogel polymer showed high binding capacity and fast adsorption/desorption kinetics for bilirubin in plasma and urine samples. The adsorption capacity of molecularly imprinted sol-gel xerogel polymer was approximately 60% higher than that of non-imprinted polymer. The effect of the conditioning, washing and elution solvents, pH, extraction time, adsorption capacity and imprinting factor were investigated. The limit of detection and the lower limit of quantification were set to 1.6 and 5nmolL(-1), respectively using plasma or urine samples. The standard calibration curves were obtained within the concentration range of 5-1000nmolL(-1) in both plasma and urine samples. The coefficients of determination values (R(2)) were ≥0.998 for all runs. The extraction recovery was approximately 80% for BR in the human plasma and urine samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. The simultaneous detection of trivalent & hexavalent chromium in exhaled breath condensate: A feasibility study comparing workers and controls.

    PubMed

    Leese, Elizabeth; Morton, Jackie; Gardiner, Philip H E; Carolan, Vikki A

    2017-04-01

    The analytical method outlined in this feasibility study has been used to show that trivalent chromium (Cr(III)) and hexavalent chromium (Cr(VI)) can be detected and measured in exhaled breath condensate (EBC) samples. EBC samples and urine samples were collected from a cohort of 58 workers occupationally exposed to hexavalent chromium compounds and 22 unexposed volunteers (control group). Levels of Cr(III) and Cr(VI) were determined in EBC samples and total chromium levels were determined in urine samples. Pre and post working week samples for both EBC and urine were collected in tandem. Total chromium in urine samples was analysed by inductively coupled plasma mass spectrometry (ICP-MS). Analysis of Cr(III) and Cr(VI) in EBC samples used a hyphenated micro liquid chromatography (μLC) system coupled to an ICP-MS. Separation was achieved using an anion exchange micro-sized column. The results showed that the occupationally exposed workers had significantly higher levels of Cr(III) and Cr(VI) in their EBC samples than the control group, as well as higher levels of total chromium in their urine samples. However, for the exposed workers no significant difference was found between pre and post working week EBC samples for either Cr(III) or Cr(VI). This study has established that Cr(III) and Cr(VI) can simultaneously be detected and measured in 'real' EBC samples and will help in understanding inhalation exposure. Crown Copyright © 2016. Published by Elsevier GmbH. All rights reserved.

  15. Evaluation of Equations for Predicting 24-Hour Urinary Sodium Excretion from Casual Urine Samples in Asian Adults.

    PubMed

    Whitton, Clare; Gay, Gibson Ming Wei; Lim, Raymond Boon Tar; Tan, Linda Wei Lin; Lim, Wei-Yen; van Dam, Rob M

    2016-08-01

    The collection of 24-h urine samples for the estimation of sodium intake is burdensome, and the utility of spot urine samples in Southeast Asian populations is unclear. We aimed to assess the validity of prediction equations with the use of spot urine concentrations. A sample of 144 Singapore residents of Chinese, Malay, and Indian ethnicity aged 18-79 y were recruited from the Singapore Health 2 Study conducted in 2014. Participants collected urine for 24 h in multiple small bottles on a single day. To determine the optimal collection time for a spot urine sample, a 1-mL sample was taken from a random bottle collected in the morning, afternoon, and evening. Published equations and a newly derived equation were used to predict 24-h sodium excretion from spot urine samples. The mean ± SD concentration of sodium from the 24-h urine sample was 125 ± 53.4 mmol/d, which is equivalent to 7.2 ± 3.1 g salt. Bland-Altman plots showed good agreement at the group level between estimated and actual 24-h sodium excretion, with biases for the morning period of -3.5 mmol (95% CI: -14.8, 7.8 mmol; new equation) and 1.46 mmol (95% CI: -10.0, 13.0 mmol; Intersalt equation). A larger bias of 25.7 mmol (95% CI: 12.2, 39.3 mmol) was observed for the Tanaka equation in the morning period. The prediction accuracy did not differ significantly for spot urine samples collected at different times of the day or at a random time of day (P = 0.11-0.76). This study suggests that the application of both our own newly derived equation and the Intersalt equation to spot urine concentrations may be useful in predicting group means for 24-h sodium excretion in urban Asian populations. © 2016 American Society for Nutrition.

  16. Daily sodium and potassium excretion can be estimated by scheduled spot urine collections.

    PubMed

    Doenyas-Barak, Keren; Beberashvili, Ilia; Bar-Chaim, Adina; Averbukh, Zhan; Vogel, Ofir; Efrati, Shai

    2015-01-01

    The evaluation of sodium and potassium intake is part of the optimal management of hypertension, metabolic syndrome, renal stones, and other conditions. To date, no convenient method for its evaluation exists, as the gold standard method of 24-hour urine collection is cumbersome and often incorrectly performed, and methods that use spot or shorter collections are not accurate enough to replace the gold standard. The aim of this study was to evaluate the correlation and agreement between a new method that uses multiple-scheduled spot urine collection and the gold standard method of 24-hour urine collection. The urine sodium or potassium to creatinine ratios were determined for four scheduled spot urine samples. The mean ratios of the four spot samples and the ratios of each of the single spot samples were corrected for estimated creatinine excretion and compared to the gold standard. A significant linear correlation was demonstrated between the 24-hour urinary solute excretions and estimated excretion evaluated by any of the scheduled spot urine samples. The correlation of the mean of the four spots was better than for any of the single spots. Bland-Altman plots showed that the differences between these measurements were within the limits of agreement. Four scheduled spot urine samples can be used as a convenient method for estimation of 24-hour sodium or potassium excretion. © 2015 S. Karger AG, Basel.

  17. Multiplexed Microsphere Suspension-Array Assay for Urine Mitochondrial DNA Typing by C-Stretch Length in Hypervariable Regions.

    PubMed

    Aoki, Kimiko; Tanaka, Hiroyuki; Kawahara, Takashi

    2018-07-01

    The standard method for personal identification and verification of urine samples in doping control is short tandem repeat (STR) analysis using nuclear DNA (nDNA). The DNA concentration of urine is very low and decreases under most conditions used for sample storage; therefore, the amount of DNA from cryopreserved urine samples may be insufficient for STR analysis. We aimed to establish a multiplexed assay for urine mitochondrial DNA typing containing only trace amounts of DNA, particularly for Japanese populations. A multiplexed suspension-array assay using oligo-tagged microspheres (Luminex MagPlex-TAG) was developed to measure C-stretch length in hypervariable region 1 (HV1) and 2 (HV2), five single nucleotide polymorphisms (SNPs), and one polymorphic indel. Based on these SNPs and the indel, the Japanese population can be classified into five major haplogroups (D4, B, M7a, A, D5). The assay was applied to DNA samples from urine cryopreserved for 1 - 1.5 years (n = 63) and fresh blood (n = 150). The assay with blood DNA enabled Japanese subjects to be categorized into 62 types, exhibiting a discriminatory power of 0.960. The detection limit for cryopreserved urine was 0.005 ng of nDNA. Profiling of blood and urine pairs revealed that 5 of 63 pairs showed different C-stretch patterns in HV1 or HV2. The assay described here yields valuable information in terms of the verification of urine sample sources employing only trace amounts of recovered DNA. However, blood cannot be used as a reference sample.

  18. Stability studies of amphetamine and ephedrine derivatives in urine.

    PubMed

    Jiménez, C; de la Torre, R; Ventura, M; Segura, J; Ventura, R

    2006-10-20

    Knowledge of the stability of drugs in biological specimens is a critical consideration for the interpretation of analytical results. Identification of proper storage conditions has been a matter of concern for most toxicology laboratories (both clinical and forensic), and the stability of drugs of abuse has been extensively studied. This concern should be extended to other areas of analytical chemistry like antidoping control. In this work, the stability of ephedrine derivatives (ephedrine, norephedrine, methylephedrine, pseudoephedrine, and norpseudoephedrine), and amphetamine derivatives (amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), and 3,4-methylenedioxymethamphetamine (MDMA)) in urine has been studied. Spiked urine samples were prepared for stability testing. Urine samples were quantified by GC/NPD or GC/MS. The homogeneity of each batch of sample was verified before starting the stability study. The stability of analytes was evaluated in sterilized and non-sterilized urine samples at different storage conditions. For long-term stability testing, analyte concentration in urine stored at 4 degrees C and -20 degrees C was determined at different time intervals for 24 months for sterile urine samples, and for 6 months for non-sterile samples. For short-term stability testing, analyte concentration was evaluated in liquid urine stored at 37 degrees C for 7 days. The effect of repeated freezing (at -20 degrees C) and thawing (at room temperature) was also studied in sterile urine for up to three cycles. No significant loss of the analytes under study was observed at any of the investigated conditions. These results show the feasibility of preparing reference materials containing ephedrine and amphetamine derivatives to be used for quality control purposes.

  19. Disruption of Membranes of Extracellular Vesicles Is Necessary for ELISA Determination of Urine AQP2: Proof of Disruption and Epitopes of AQP2 Antibodies

    PubMed Central

    Nameta, Masaaki; Saijo, Yoko; Ohmoto, Yasukazu; Katsuragi, Kiyonori; Yamamoto, Keiko; Yamamoto, Tadashi; Ishibashi, Kenichi; Sasaki, Sei

    2016-01-01

    Aquaporin-2 (AQP2) is present in urine extracellular vesicles (EVs) and is a useful biomarker for water balance disorders. We previously found that pre-treatment of urine with alkali/detergent or storage at −25 °C is required for enzyme-linked immunosorbent assay (ELISA) measurement. We speculated that disruptions of EVs membranes are necessary to allow for the direct contact of antibodies with their epitopes. Human urine EVs were prepared using an ultracentrifugation method. Urine EV samples were stored at different temperatures for a week. Electron microscopy showed abundant EVs with diameters of 20–100 nm, consistent with those of exosomes, in normal urine, whereas samples from alkali/detergent pre-treated urine showed fewer EVs with large swollen shapes and frequent membrane disruptions. The abundance and structures of EVs were maintained during storage at −80 °C, but were severely damaged at −25 °C. Binding and competitive inhibition assays showed that epitopes of monoclonal antibody and polyclonal antibody were the hydrophilic Loop D and C-terminus of AQP2, respectively, both of which are present on the inner surface of EVs. Thus, urine storage at −25 °C or pre-treatment with alkali/detergent disrupt EVs membranes and allow AQP2 antibodies to bind to their epitopes located inside EVs. PMID:27681727

  20. Prevalence of caffeine use in elite athletes following its removal from the World Anti-Doping Agency list of banned substances.

    PubMed

    Del Coso, Juan; Muñoz, Gloria; Muñoz-Guerra, Jesús

    2011-08-01

    The aim of this investigation was to determine the use of caffeine by athletes after its removal from the World Anti-Doping Agency list. For this purpose, we measured the caffeine concentration in 20 686 urine samples obtained for doping control from 2004 to 2008. We utilized only urine samples obtained after official national and international competitions. Urine caffeine concentration was determined using alkaline extraction followed by gas chromatography-mass spectrometry. The limit of detection (LOD) was set at 0.1 µg·mL(-1). The percentage of urine samples below the LOD was 26.2%; the remaining 73.8% of the urine samples contained caffeine. Most urine samples (67.3%) had urinary caffeine concentrations below 5 µg·mL(-1). Only 0.6% of urine samples exceeded the former threshold for caffeine doping (12 µg·mL(-1)). Triathlon (3.3 ± 2.2 µg·mL(-1)), cycling (2.6 ± 2.0 µg·mL(-1)), and rowing (1.9 ± 1.4 µg·mL(-1)) were the sports with the highest levels of urine caffeine concentration; gymnastics was the sport with the lowest urine caffeine concentration (0.5 ± 0.4 µg·mL(-1)). Older competitors (>30 y) had higher levels of caffeine in their urine than younger competitors (<20 y; p < 0.05); there were no differences between males and females. In conclusion, 3 out of 4 athletes had consumed caffeine before or during sports competition. Nevertheless, only a small proportion of these competitors (0.6%) had a urine caffeine concentration higher than 12 µg·mL(-1). Endurance sports were the disciplines showing the highest urine caffeine excretion after competition.

  1. Surveying Mercury Levels in Hair, Blood and Urine of under 7-Year Old Children from a Coastal City in China

    PubMed Central

    Chen, Guixia; Chen, Xiaoxin; Yan, Chonghuai; Wu, Xingdong; Zeng, Guozhang

    2014-01-01

    Aim: The average mercury load in children under 7-years old was determined in a populated but not overly industrial coastal area in China. Methods: 395 blood samples, 1072 urine samples, and 581 hair samples were collected from 1076 children, aged 0 to 6 years, from eight representative communities of Xiamen, China. Mercury levels in the samples were surveyed. Results: The 95% upper limits of mercury in blood, urine, and hair for the children were 2.30, 1.50 and 2100.00 μg/kg, respectively. Levels tended to increase with age. Correlation analyses showed that mercury levels in blood and urine correlated with those in hair (n = 132), r = 0.49, p < 0.0001 and r = 0.20, p = 0.0008; however, blood mercury levels did not correlate with urine levels (n = 284), r = 0.07, p = 0.35. Conclusions: Surveying the average mercury load in children 0 to 6 years, and the 95% upper limit value of mercury in their blood, urine, and hair should help guide risk assessment and health management for children. PMID:25419876

  2. Gene expression signature in urine for diagnosing and assessing aggressiveness of bladder urothelial carcinoma.

    PubMed

    Mengual, Lourdes; Burset, Moisès; Ribal, María José; Ars, Elisabet; Marín-Aguilera, Mercedes; Fernández, Manuel; Ingelmo-Torres, Mercedes; Villavicencio, Humberto; Alcaraz, Antonio

    2010-05-01

    To develop an accurate and noninvasive method for bladder cancer diagnosis and prediction of disease aggressiveness based on the gene expression patterns of urine samples. Gene expression patterns of 341 urine samples from bladder urothelial cell carcinoma (UCC) patients and 235 controls were analyzed via TaqMan Arrays. In a first phase of the study, three consecutive gene selection steps were done to identify a gene set expression signature to detect and stratify UCC in urine. Subsequently, those genes more informative for UCC diagnosis and prediction of tumor aggressiveness were combined to obtain a classification system of bladder cancer samples. In a second phase, the obtained gene set signature was evaluated in a routine clinical scenario analyzing only voided urine samples. We have identified a 12+2 gene expression signature for UCC diagnosis and prediction of tumor aggressiveness on urine samples. Overall, this gene set panel had 98% sensitivity (SN) and 99% specificity (SP) in discriminating between UCC and control samples and 79% SN and 92% SP in predicting tumor aggressiveness. The translation of the model to the clinically applicable format corroborates that the 12+2 gene set panel described maintains a high accuracy for UCC diagnosis (SN = 89% and SP = 95%) and tumor aggressiveness prediction (SN = 79% and SP = 91%) in voided urine samples. The 12+2 gene expression signature described in urine is able to identify patients suffering from UCC and predict tumor aggressiveness. We show that a panel of molecular markers may improve the schedule for diagnosis and follow-up in UCC patients. Copyright 2010 AACR.

  3. Determination of γ-hydroxybutyrate in human urine samples by ion exclusion and ion exchange two-dimensional chromatography system.

    PubMed

    Liu, Junwei; Deng, Zhifen; Zhu, Zuoyi; Wang, Yong; Wang, Guoqing; Sun, Yu-An; Zhu, Yan

    2017-12-15

    A two-dimensional ion chromatography system was developed for the determination of γ-hydroxybutyrate (GHB) in human urine samples. Ion exclusion chromatography was used in the first dimensional separation for elimination of urine matrices and detection of GHB above 10mgL -1 , ion exchange chromatography was used in the second dimensional separation via column-switching technique for detection of GHB above 0.08mgL -1 . Under the optimized chromatographic conditions, the ion exclusion and ion exchange chromatography separation system exhibited satisfactory repeatability (RSD<3.1%, n=6) and good linearity in the range of 50-1000mgL -1 and 0.5-100mgL -1 , respectively. By this method, concentrations of GHB in the selected human urine samples were detected in the range of 0-1.57mgL -1 . The urine sample containing 0.89mgL -1 GHB was selected to evaluate the accuracy; the spiked recoveries of GHB were 95.9-102.8%. The results showed that the two-dimensional ion chromatography system was convenient and practical for the determination of GHB in human urine samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Effect of injected rotenone on the production and composition of urine from the rainbow trout (Salmo gairdneri)

    USGS Publications Warehouse

    Erickson, D.A.; Gingerich, W.H.

    1986-01-01

    Renal function was evaluated in adult rainbow trout (Salmo gairdneri) dosed i.a. with rotenone at 225 and 275 μg/kg. The chemical composition of urine samples and urine flow rates collected over a 5-h pretreatment period were compared with hourly urine samples collected over a 5-h posttreatment period. Significant increases in osmolality and in concentrations of sodium, potassium, chloride, glucose, and total protein were observed in the urine of treated fish. Urine solute concentrations reached maximum values within 1 to 3 h after treatment and decreased thereafter, indicating that the effects were reversible. Concentrations of sodium and chloride were highly correlated in 2-h posttreatment urine samples at the low (r = 0.922) and high (r = 0.981) rotenone treatments. Urine flow rates were reduced in trout at each dose of rotenone but the decrease in volume of urine voided was not dose-dependent. In a separate study, [14C]polyethylene glycol was used as a filtration marker to determine the effect of rotenone treatment (225 &mu:g/kg) on urine flow rate, glomerular filtration rate, and renal water reabsorption. We showed that posttreatment urine flow rates were reduced partly by reduced glomerular filtration and partly by increased water reabsorption. Transient increases in plasma osmolality and hematocrit also were observed 0.5 h after rotenone treatment.

  5. Comparison of Uriswab to alternative methods for urine culture collection and transport: confirmation of standard culture methodology for investigation of urinary tract infections.

    PubMed

    Rennie, Robert P; Turnbull, Lee-Ann; Gauchier-Pitts, Kaylee; Bennett, Tracy; Dyrland, Debbie; Blonski, Susan

    2016-08-01

    The ability to isolate and identify causative agents of urinary tract infections relies primarily on the quality of the urine sample that is submitted to the microbiology. The most important factors are the method of collection, the maintenance of viability of the potential pathogens during transport, and standardization of the culturing of the urine sample. This report is a composite of several investigations comparing collection and transport on urine culture paddles, with a preservative urine sponge (Uriswab), and a comparison of Uriswab with the BD preservative transport tube as methods of preservation of urinary pathogens. Primary studies showed that Uriswab maintained significantly more urinary pathogens than the urine culture paddle with fewer mixed or contaminated cultures. The two preservative transport systems were comparable for maintenance of viability of the pathogens, but there were fewer mixed cultures when samples were collected with Uriswab. This study confirms the importance of a standard volume of 1 μL of urine for culture. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Evaluation of 1,5-anhydro-d-glucitol in clinical and forensic urine samples.

    PubMed

    Sydow, Konrad; Wiedfeld, Christopher; Musshoff, Frank; Madea, Burkhard; Tschoepe, Diethelm; Stratmann, Bernd; Hess, Cornelius

    2018-06-01

    Because of the lack of characteristic morphological findings post mortem diagnosis of diabetes mellitus and identification of diabetic coma can be complicated. 1,5-Anhydroglucitol (1,5-AG), the 1-deoxy form of glucose, competes with glucose for renal reabsorption. Therefore low serum concentrations of 1,5-AG, reflect hyperglycemic excursions over the prior 1-2 weeks in diabetic patients. Next to clinical applications determination of 1,5-AG can also be used in forensic analysis. To investigate the elimination of 1,5-AG, a liquid chromatographic-mass spectrometric method for the determination of 1,5-AG and creatinine in urine was developed and validated according to international guidelines. To evaluate ante mortem concentrations of 1,5-AG spot urine samples of 30 healthy subjects, 46 type 1 and 46 type 2 diabetic patients were analyzed. 1,5-AG urine concentrations of diabetic patients were significantly (p<0.001) lower (mean: 1.54μg/ml, n=92) compared to concentrations of healthy subjects (mean: 4.76μg/ml, n=30) which led to the idea that 1,5-AG urine concentrations post mortem might help in the interpretation of a diabetic coma post mortem. Urine of 47 deceased non-diabetics, 37 deceased diabetic and 9 cases of diabetic coma were measured. Comparison of blood and urine 1,5-AG concentrations in clinic samples (linear, R 2 =0.13) and forensic samples (linear, R 2 =0.02) showed no correlation. Urinary levels of 1,5-AG in deceased diabetic (mean 6.9μg/ml) and in non-diabetic patients (mean 6.3μg/ml) did not show a significant difference (p=0.752). However, urinary 1,5-AG concentrations in deceased due to diabetic coma (mean: 1.7μg/ml) were significantly lower than in non-diabetic (mean: 6.3μg/ml, p=0.039) and lower than in diabetic cases (mean: 4.7μg/ml, p=0.058). The determination of a reliable cut-off for the differentiation of diabetic to diabetic coma cases was not possible. Normalization of urinary 1,5-AG concentrations with the respective creatinine concentrations did not show any gain of information. In clinical (serum) and forensic blood samples a significant difference between all groups could be detected (p<0.05). Comparison of blood and urine 1,5-AG concentrations in clinical samples (linear, R 2 =0.13) and forensic samples (linear, R 2 =0.02) showed no correlation. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. 51Cr-EDTA absorption blood test: an easy method for assessing small intestinal permeability in dogs.

    PubMed

    Frias, Rafael; Sankari, Satu; Westermarck, Elias

    2004-01-01

    The 51Cr-EDTA test is a valuable clinical tool for screening intestinal diseases in dogs. The test is performed by calculating the percentage of recovery from urine of a PO-ingested dose of 51Cr-EDTA after 6 or 24 hours. Careful urine collection is a practical limitation of this test in dogs, and our goal was to develop a simpler test that measures 51Cr-EDTA in blood. A 51Cr-EDTA absorption test was simultaneously performed on urine and serum 43 times in healthy Beagle Dogs. Timed blood samples were withdrawn, and urine was collected during a 6-hour period. Percentages of the ingested dose were then calculated in urine and serum. The mean +/- standard deviation (range) percentage in urine after 6 hours was 14.07 +/- 8.72% (3.81-34.18%), whereas results in serum from samples taken at 2, 3, 4, 5, and 6 hours were 0.49 +/- 0.45% (0.02-2.13%), 0.75 +/- 0.52% (0.03-1.89%), 0.82 +/- 0.57% (0.13-2.21%), 0.70 +/- 0.53% (0.12-1.99%), and 0.47 +/- 0.44% (0.11-1.79%), respectively. The results for blood specimens showed good concordance with those for urine, especially for the samples taken at 4 hours (r = 0.89). Moreover, the correlation between urine and blood was better when the sum of the percentages of the recovered analyte from various blood samples was compared with urine. The correlation coefficient when summing 4 blood samples was excellent (r = 0.97) and remained excellent when summing only 2 blood samples taken at 3 and 5 hours (r = 0.95) or at 3 and 4 hours (r = 0.94). We conclude that a serum 51Cr-EDTA test determined by summing successive blood samples provides an easier means of estimating small intestinal permeability in dogs and gives results comparable to those of the 6-hour urine test.

  8. Mutagenic activity and metabolites in the urine of workers exposed to trinitrotoluene (TNT).

    PubMed Central

    Ahlborg, G; Einistö, P; Sorsa, M

    1988-01-01

    Urine samples taken after work and after a free weekend from 50 workers employed in various activities in a chemical plant manufacturing explosives were analysed. On the basis of hygienic surveys, the subjects were divided into three categories of exposure to trinitrotoluene (TNT). The urine analyses consisted of gas chromatographic identification of TNT and its two metabolites, 4-ADNT and 2-ADNT, and a determination of the mutagenic activity. Two frame shift detector strains of Salmonella typhimurium were used, TA 98 and TA 98 NR, the latter being deficient in endogenous nitroreductase activity. On the basis of previous results on TNT mutagenicity, no exogeneous metabolic system was used to test the urine concentrates. Both tester strains showed that the mean urinary mutagenic activity was higher in the after work samples than in post weekend samples from the same subjects, showing that bacterial nitroreductase activity was not significantly responsible for the mutagenicity, although the response was higher with strain TA 98 than with TA 98 NR. The interindividual variation in urine mutagenicity was high, however, and the difference between the two sampling times was statistically significant (p less than 0.05) only for the high exposed group (workers in trotyl foundry and sieve house). Correlation between urinary mutagenicity and concentration of TNT in urine was poor; correlation was significant only with the urinary concentration of 4-ADNT. The correlation between urinary TNT and both metabolites was good (p less than 0.001). These results suggest that analysis of 4-ADNT in urine would be a sufficient biological measure for controlling exposure to TNT. PMID:3378017

  9. Screening for urinary tract infection with the Sysmex UF-1000i urine flow cytometer.

    PubMed

    Broeren, Maarten A C; Bahçeci, Semiha; Vader, Huib L; Arents, Niek L A

    2011-03-01

    The diagnosis of urinary tract infection (UTI) by urine culture is time-consuming and can produce up to 60 to 80% negative results. Fast screening methods that can reduce the necessity for urine cultures will have a large impact on overall turnaround time and laboratory economics. We have evaluated the detection of bacteria and leukocytes by a new urine analyzer, the UF-1000i, to identify negative urine samples that can be excluded from urine culture. In total, 1,577 urine samples were analyzed and compared to urine culture. Urine culture showed growth of ≥10(3) CFU/ml in 939 samples (60%). Receiver operating characteristics (ROC) curves and ROC decision plots were been prepared at three different gold standard definitions of a negative urine culture: no growth, growth of bacteria at <10(4) CFU/ml, and growth of bacteria at <10(5) CFU/ml. Also, the reduction in urine cultures and the percentage of false negatives were calculated. At the most stringent gold standard definition of no growth, a chosen sensitivity of 95% resulted in a cutoff value of 26 bacteria/μl, a specificity of 43% and a reduction in urine cultures of only 20%, of which 14% were false negatives. However, at a gold standard definition of <10(5) CFU/ml and a sensitivity of 95%, the UF-1000i cutoff value was 230 bacteria/μl, the specificity was 80%, and the reduction in urine cultures was 52%, of which 0.3% were false negatives. The applicability of the UF-1000i to screen for negative urine samples strongly depends on population characteristics and the definition of a negative urine culture. In our setting, however, the low workload savings and the high percentage of false-negative results do not warrant the UF-1000i to be used as a screening analyzer.

  10. Temporal variability of urinary cadmium in spot urine samples and first morning voids.

    PubMed

    Vacchi-Suzzi, Caterina; Porucznik, Christina A; Cox, Kyley J; Zhao, Yuan; Ahn, Hongshik; Harrington, James M; Levine, Keith E; Demple, Bruce; Marsit, Carmen J; Gonzalez, Adam; Luft, Benjamin; Meliker, Jaymie R

    2017-05-01

    Cadmium is a carcinogenic heavy metal. Urinary levels of cadmium are considered to be an indicator of long-term body burden, as cadmium accumulates in the kidneys and has a half-life of at least 10 years. However, the temporal stability of the biomarker in urine samples from a non-occupationally exposed population has not been rigorously established. We used repeated measurements of urinary cadmium (U-Cd) in spot urine samples and first morning voids from two separate cohorts, to assess the temporal stability of the samples. Urine samples from two cohorts including individuals of both sexes were measured for cadmium and creatinine. The first cohort (Home Observation of Perinatal Exposure (HOPE)) consisted of 21 never-smokers, who provided four first morning urine samples 2-5 days apart, and one additional sample roughly 1 month later. The second cohort (World Trade Center-Health Program (WTC-HP)) consisted of 78 individuals, including 52 never-smokers, 22 former smokers and 4 current smokers, who provided 2 spot urine samples 6 months apart, on average. Intra-class correlation was computed for groups of replicates from each individual to assess temporal variability. The median creatinine-adjusted U-Cd level (0.19 and 0.21 μg/g in the HOPE and WTC-HP, respectively) was similar to levels recorded in the United States by the National Health and Nutrition Examination Survey. The intra-class correlation (ICC) was high (0.76 and 0.78 for HOPE and WTC-HP, respectively) and similar between cohorts, irrespective of whether samples were collected days or months apart. Both single spot or first morning urine cadmium samples show good to excellent reproducibility in low-exposure populations.

  11. [Examination about utility of a Streptococcus pneumoniae capsular antigen swiftness search kit urine in a pneumonia patient].

    PubMed

    Hashikita, Giichi; Yamaguti, Toshiyuki; Tachi, Yoshimi; Kishi, Etsuko; Kawamura, Toru; Takahashi, Shun; Arai, Yukie; Koyama, Sachie; Huruhata, Toshihumi; Itabashi, Akira; Oka, Yoko; Yamazaki, Tsutomu; Maesaki, Sigefumi

    2005-01-01

    We investigated the usefullness of Binax NOW urine antigen test, an immunochromatographic assay that binds any soluble Streptococcus pneumoniae antigen (C polysaccharide) for the diagnosis of penumoniae form September 2003 to March 2005. We used 372 samples form the patinets with pneumoniae diagnosed for blood or sputum cultuter or gram-stained sputum smear. Out of 24 culture positive specimens, Binax NOW urine antigen test, showed positive in 18 (75%) specimens. The sensitivity of sputum and blood culture was 71.7% and 83.3%, respectively. Binax NOW urine antigen test was seemed false positives in 55 samples, false negatives in 6 samples. The specificity of Binax NOW urine antigen test was evaluated 84.1%. Overall agreement among tests was 83.6%. When compared to culture, false negative urine antigen may be the result of colonizing S. pneumoniae in sputum or pneumonia caused by an agent other than S. pneumoniae. CRP values for cases were both urine antigen and culture were positive ranged from 40 mg/dl to 10 mg/dl while urine antigen and culture negative cases were predominantly less than 10 mg/dl. Positive blood and pleural fluid culture cases were consistently associated with strongly positive urine antigen tests. Non-agreement between urine antigen, culture, and microscopy may be the result of specimen quality, labile nature of S. pneumoniae and antimicrobial therapy.

  12. The ultimate veal calf reference experiment: hormone residue analysis data obtained by gas and liquid chromatography tandem mass spectrometry.

    PubMed

    Nielen, Michel W F; Lasaroms, Johan J P; Essers, Martien L; Sanders, Marieke B; Heskamp, Henri H; Bovee, Toine F H; van Rhijn, J Hans; Groot, Maria J

    2007-03-14

    A lifetime controlled reference experiment has been performed using 42 veal calves, 21 males and 21 females which were fed and housed according to European regulations and common veterinary practice. During the experiment feed, water, urine and hair were sampled and feed intake and growth were monitored. Thus for the first time residue analysis data were obtained from guaranteed lifetime-untreated animals. The analysis was focused on the natural hormones estradiol and testosterone and their metabolites, on 17beta- and 17alpha-nortestosterone, on 17beta- and 17alpha-boldenone and androsta-1,4-diene-3,17-dione (ADD), and carried out by gas chromatography tandem mass spectrometry (GC/MS/MS), an estrogen bioassay and liquid chromatography (LC) MS/MS. Feed, water and hair samples were negative for the residues tested. Female calf urines showed occasionally low levels of 17alpha-estradiol and 17alpha-testosterone. On one particular sampling day male veal calf urines showed very high levels of 17alpha-testosterone (up to 1000 ng mL(-1)), accompanied by lower levels of estrone and 17beta-testosterone. Despite these extreme levels of natural testosterone, 17beta-boldenone was never detected in the same urine samples; even 17alpha-boldenone and ADD were only occasionally beyond CCalpha (maximum levels 2.7 ng mL(-1)). The data from this unique experiment provide a set of reference values for steroid hormones in calf urine and demonstrate that 17beta-boldenone is not a naturally occurring compound in urine samples.

  13. Understanding arsenic metabolism through a comparative study of arsenic levels in the urine, hair and fingernails of healthy volunteers from three unexposed ethnic groups in the United Kingdom

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brima, Eid I.; Haris, Parvez I.; Jenkins, Richard O.

    2006-10-01

    Very little is known about arsenic (As) metabolism in healthy populations that are not exposed to high concentrations of As in their food or water. Here we present a study with healthy volunteers from three different ethnic groups, residing in Leicester, UK, which reveals statistically significant differences in the levels of total As in urine and fingernail samples. Urine (n = 63), hair (n = 36) and fingernail (n = 36) samples from Asians, Somali Black-Africans and Whites were analysed using inductively coupled plasma mass spectrometry (ICP-MS) and graphite furnace atomic absorption spectroscopy (GF-AAS). The results clearly show that themore » total concentrations of As in urine and fingernail samples of a Somali Black-African population (urine 7.2 {mu}g/g creatinine; fingernails 723.1 {mu}g/kg) are significantly (P < 0.05) different from the Asian (urine 24.5 {mu}g/g creatinine; fingernails 153.9 {mu}g/kg) and White groups (urine 20.9 {mu}g/g creatinine; fingernails 177.0 {mu}g/kg). The chemical speciation of As in the urine of the three groups was also measured using high performance liquid chromatography coupled to ICP-MS. This showed that the proportion of the total urinary As present as dimethylarsenate (DMA) was higher for the Somali Black-African group (50%) compared to the Asians (16%) and Whites (22%). However, there was no significant difference (P > 0.05) in the level of As in the hair samples from these three groups; Somali Black-Africans (116.0 {mu}g/kg), Asians (117.4 {mu}g/kg) and Whites (141.2 {mu}g/kg). Significantly different levels of total As in fingernail and urine and a higher percentage of urinary DMA in the Somali Black-Africans are suggestive of a different pattern of As metabolism in this ethnic group.« less

  14. Epidemiology of Schistosomiasis and Usefulness of Indirect Diagnostic Tests in School-Age Children in Cubal, Central Angola

    PubMed Central

    Bocanegra, Cristina; Gallego, Sara; Mendioroz, Jacobo; Moreno, Milagros; Sulleiro, Elena; Salvador, Fernando; Sikaleta, Nicolau; Nindia, Arlette; Tchipita, Daniel; Joromba, Morais; Kavaya, Sebastiao; Sánchez Montalvá, Adrián; López, Teresa; Molina, Israel

    2015-01-01

    Introduction Schistosomiasis remains a public health major problem and little is known in many areas, mainly in Sub-Saharan Africa Objectives To assess the burden and risk factors of schistosomiasis and intestinal parasitic helminthes in the children of Cubal, Angola, and to compare different diagnostic approaches for urinary schistosomiasis under field conditions. Methods A cross-sectional study was conducted. Urine and faeces samples of school children were microscopically studied. A random sample of children was obtained from an alphabetically arranged list of children, taking one of two children. Urine dipstick, colorimetric test and macrohaematuria were considered as indirect diagnostic methods and compared to direct urine examination. Possible risk factors for the infection were sex, age, distance to the river and previous treatment with praziquantel; the assessment was performed using Chi-square test. Results A total of 785 (61.18%) children showed S. haematobium eggs in urine; children living within 500 meters from the river had a higher odds for infection: Odds ratio 1.97 (1.45–2.7 CI 95%); urine dipstick showed sensitivity of 96% and specificity of 61.3%, with a positive predictive value; colorimetric test showed sensitivity of 52.5%, specificity of 74.6% and a positive predictive value of 77%. Proteinuria was present in 653 (51.1%) children, being more frequent in children with S. haematobium in urine (75.2%); 32 of 191 stool samples (16%) showed the presence of other intestinal parasites and 8 (4%) for S. haematobium. Conclusions Prevalence of urinary schistosomiasis in our study area is much higher than the national average, considering it as a high-risk community. Proximity to a source of water was a risk factor for the infection. Indirect tests, as urine dipstick and colorimetric test, were useful tools for diagnosis, due to ease of use and low cost. Proteinuria was a common finding, probably showing an early structural damage due to schistosomiasis in this group of children. PMID:26474169

  15. Ultrasonic-based membrane aided sample preparation of urine proteomes.

    PubMed

    Jesus, Jemmyson Romário; Santos, Hugo M; López-Fernández, H; Lodeiro, Carlos; Arruda, Marco Aurélio Zezzi; Capelo, J L

    2018-02-01

    A new ultrafast ultrasonic-based method for shotgun proteomics as well as label-free protein quantification in urine samples is developed. The method first separates the urine proteins using nitrocellulose-based membranes and then proteins are in-membrane digested using trypsin. The enzymatic digestion process is accelerated from overnight to four minutes using a sonoreactor ultrasonic device. Overall, the sample treatment pipeline comprising protein separation, digestion and identification is done in just 3h. The process is assessed using urine of healthy volunteers. The method shows that male can be differentiated from female using the protein content of urine in a fast, easy and straightforward way. 232 and 226 proteins are identified in urine of male and female, respectively. From this, 162 are common to both genders, whilst 70 are unique to male and 64 to female. From the 162 common proteins, 13 are present at levels statistically different (p < 0.05). The method matches the analytical minimalism concept as outlined by Halls, as each stage of this analysis is evaluated to minimize the time, cost, sample requirement, reagent consumption, energy requirements and production of waste products. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Immunoreactive LH in long-term frozen human urine samples.

    PubMed

    Singh, Gurmeet Kaur Surindar; Jimenez, Mark; Newman, Ron; Handelsman, David J

    2014-04-01

    Urine provides a convenient non-invasive alternative to blood sampling for measurement of certain hormones. Urinary luteinizing hormone (LH) measurements have been used for endocrinology research and anti-doping testing. However, the commercially available LH immunoassays are developed and validated for human blood samples but not urine so that LH assays intended for use with urine samples need thorough validation. Therefore, the present study evaluated the measurement of urinary LH immunoreactivity using previously validated immunofluorometric (IF) and immunochemiluminometric (ICL) LH assays after prolonged frozen storage. LH was measured in serial urine samples following administration of a single injection of one of two doses of recombinant human chorionic hormone (rhCG) with assays run at the end of study (2008) and again after four years of frozen (-20 °C) storage where samples were stored without adding preservatives. The ICL assay showed quantitatively reproducible LH measurements after prolonged -20 °C storage. However, the IF immunoassay gave consistently lower LH levels relative to ICL (2008) with a further proportionate reduction after four years of sample storage (2012). Yet, both the assays displayed similar patterns of the time-course of urine LH measurement both before and after four years of frozen storage. In conclusion, we found that both immunoassays are suitable for urinary LH measurements with ICL assay being more robust for quantitative urinary LH measurement such as for anti-doping purposes, whereas the IF could be applicable for research studies where urine LH levels are compared within-study but not in absolute terms. Copyright © 2013 John Wiley & Sons, Ltd.

  17. Significant increase in cultivation of Gardnerella vaginalis, Alloscardovia omnicolens, Actinotignum schaalii, and Actinomyces spp. in urine samples with total laboratory automation.

    PubMed

    Klein, Sabrina; Nurjadi, Dennis; Horner, Susanne; Heeg, Klaus; Zimmermann, Stefan; Burckhardt, Irene

    2018-04-13

    While total laboratory automation (TLA) is well established in laboratory medicine, only a few microbiological laboratories are using TLA systems. Especially in terms of speed and accuracy, working with TLA is expected to be superior to conventional microbiology. We compared in total 35,564 microbiological urine cultures with and without incubation and processing with BD Kiestra TLA for a 6-month period each retrospectively. Sixteen thousand three hundred thirty-eight urine samples were analyzed in the pre-TLA period and 19,226 with TLA. Sixty-two percent (n = 10,101/16338) of the cultures processed without TLA and 68% (n = 13,102/19226) of the cultures processed with TLA showed growth. There were significantly more samples with two or more species per sample and with low numbers of colony forming units (CFU) after incubation with TLA. Regarding the type of bacteria, there were comparable amounts of Enterobacteriaceae in the samples, slightly less non-fermenting Gram-negative bacteria, but significantly more Gram-positive cocci, and Gram-positive rods. Especially Alloscardivia omnicolens, Gardnerella vaginalis, Actinomyces spp., and Actinotignum schaalii were significantly more abundant in the samples incubated and processed with TLA. The time to report was significantly lower in the TLA processed samples by 1.5 h. We provide the first report in Europe of a large number of urine samples processed with TLA. TLA showed enhanced growth of non-classical and rarely cultured bacteria from urine samples. Our findings suggest that previously underestimated bacteria may be relevant pathogens for urinary tract infections. Further studies are needed to confirm our findings.

  18. Towards a method of rapid extraction of strontium-90 from urine: urine pretreatment and alkali metal removal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hawkins, C.; Dietz, M.; Kaminski, M.

    2016-03-01

    A technical program to support the Centers of Disease Control and Prevention is being developed to provide an analytical method for rapid extraction of Sr-90 from urine, with the intent of assessing the general population’s exposure during an emergency response to a radiological terrorist event. Results are presented on the progress in urine sample preparation and chemical separation steps that provide an accurate and quantitative detection of Sr-90 based upon an automated column separation sequence and a liquid scintillation assay. Batch extractions were used to evaluate the urine pretreatment and the column separation efficiency and loading capacity based upon commercial,more » extractant-loaded resins. An efficient pretreatment process for decolorizing and removing organics from urine without measurable loss of radiostrontium from the sample was demonstrated. In addition, the Diphonix® resin shows promise for the removal of high concentrations of common strontium interferents in urine as a first separation step for Sr-90 analysis.« less

  19. The influence of freezer storage of urine samples on the BONN-Risk-Index for calcium oxalate crystallization.

    PubMed

    Laube, Norbert; Zimmermann, Diana J

    2004-01-01

    This study was performed to quantify the effect of a 1-week freezer storage of urine on its calcium oxalate crystallization risk. Calcium oxalate is the most common urinary stone material observed in urolithiasis patients in western and affluent countries. The BONN-Risk-Index of calcium oxalate crystallization risk in human urine is determined from a crystallization experiment performed on untreated native urine samples. We tested the influence of a 1-week freezing on the BONN-Risk-Index value as well as the effect of the sample freezing on the urinary osmolality. In vitro crystallization experiments in 49 native urine samples from stone-forming and non-stone forming individuals were performed in order to determine their calcium oxalate crystallization risk according to the BONN-Risk-Index approach. Comparison of the results derived from original sample investigations with those obtained from the thawed aliquots by statistical evaluation shows that i) no significant deviation from linearity between both results exists and ii) both results are identical by statistical means. This is valid for both, the BONN-Risk-Index and the osmolality data. The differences in the BONN-Risk-Index results of both procedures of BONN-Risk-Index determination, however, exceed the clinically acceptable difference. Thus, determination of the urinary calcium oxalate crystallization risk from thawed urine samples cannot be recommended.

  20. Urinary creatinine concentrations in an industrial workforce and comparison with reference values of the general population.

    PubMed

    Bader, Michael; Messerer, Peter; Will, Wolfgang

    2013-08-01

    Urinary creatinine is an important parameter for the adjustment of metabolite concentrations in differently diluted urine specimens, as a reference dimension for biological limit or guidance values and as a selection criterion for spot urine samples in human biomonitoring. While the creatinine output of the general population has been well described in environmental surveys, this study focused specifically on creatinine concentrations in a large industrial workforce in order to compare these data with the general population and to provide a database for the calculation of a reasonable conversion factor between volume-related and creatinine-adjusted data and vice versa. Urinary creatinine was analysed in 6,438 spot urine samples by a photometric assay in the time period between 1989 and 2009. Basic demographic data (age, sex, body weight, body height) and job category (apprentices, skilled craftsmen, skilled chemical workers, foremen, laboratory staff and executives) were considered in a statistical analysis. The median concentration of urinary creatinine in all urine samples was 1.36 g/L with male employees showing significantly higher values (1.37 g/L, n = 6,148 samples) than female employees (1.00 g/L, n = 290) and concentrations ranging from 0.01 up to 9.76 g/L. Age, body mass index and job category were significant influence factors on urinary creatinine. About 92 % of all samples showed creatinine concentrations between 0.3 and 3.0 g/L, a range recommended by the World Health Organization as a criterion for valid spot urine samples. The results of this study correspond well with data from environmental surveys and with recent data from an active workforce in industry with similar sampling strategies. Therefore, a median of 1.4 g creatinine per litre urine seems to be a reasonable value for general calculations and adjustments. The study data also support the validity of the current recommendations by the WHO and several scientific committees and institutions with respect to creatinine limits in spot urine samples for occupational-medical biomonitoring.

  1. Impedimetric method for measuring ultra-low E. coli concentrations in human urine.

    PubMed

    Settu, Kalpana; Chen, Ching-Jung; Liu, Jen-Tsai; Chen, Chien-Lung; Tsai, Jang-Zern

    2015-04-15

    In this study, we developed an interdigitated gold microelectrode-based impedance sensor to detect Escherichia coli (E. coli) in human urine samples for urinary tract infection (UTI) diagnosis. E. coli growth in human urine samples was successfully monitored during a 12-h culture, and the results showed that the maximum relative changes could be measured at 10Hz. An equivalent electrical circuit model was used for evaluating the variations in impedance characteristics of bacterial growth. The equivalent circuit analysis indicated that the change in impedance values at low frequencies was caused by double layer capacitance due to bacterial attachment and formation of biofilm on electrode surface in urine. A linear relationship between the impedance change and initial E. coli concentration was obtained with the coefficient of determination R(2)>0.90 at various growth times of 1, 3, 5, 7, 9 and 12h in urine. Thus our sensor is capable of detecting a wide range of E. coli concentration, 7×10(0) to 7×10(8) cells/ml, in urine samples with high sensitivity. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. The consequence of delayed fixation on subsequent preservation of urine cells.

    PubMed

    Ahmed, Hussain G; Tom, Murtada Am

    2011-01-01

    Degenerative changes caused by delays in urine preservation contribute to false-negative and false-positive interpretation of urothelial disease in cytology. The aim of this study is to assess whether the delay of fixation of urine samples makes any significant difference to urine cytology and morphology, and the limit of acceptability of delay for routine use in the hospital laboratory. Three cell collection fluids were evaluated by analyzing the preservation and degeneration of cells in urine samples. In this study, 50 voided urine specimens were taken at random from females complaining of vaginal discharge. Each specimen was divided into three sterile containers. The first was immediately centrifugated and the deposit was smeared onto a cleaned micro slide and immediately fixed into 95% ethyl alcohol for 15 minutes. The remaining two were prepared in the same manner, however, the second after two hours of collection and the third after four hours of collection. The degree of degeneration and thus the preservation were assessed by a table of chosen criteria, then ranked and analyzed using Friedman's nonparametric test, at p=0.05. The results showed a significant difference between the preservation and the delay in urine fixation, p<0.0001. Any delay in fixation of urine specimen for cytology affects the preservation of cells, which may result in miss diagnosis. It is recommended that urine samples for cytology should be fixed immediately after collection.

  3. Analytical precision of the Urolizer for the determination of the BONN-Risk-Index (BRI) for calcium oxalate urolithiasis and evaluation of the influence of 24-h urine storage at moderate temperatures on BRI.

    PubMed

    Berg, Wolfgang; Bechler, Robin; Laube, Norbert

    2009-01-01

    Since its first publication in 2000, the BONN-Risk-Index (BRI) has been successfully used to determine the calcium oxalate (CaOx) crystallization risk from urine samples. To date, a BRI-measuring device, the "Urolizer", has been developed, operating automatically and requiring only a minimum of preparation. Two major objectives were pursued: determination of Urolizer precision, and determination of the influence of 24-h urine storage at moderate temperatures on BRI. 24-h urine samples from 52 CaOx stone-formers were collected. A total of 37 urine samples were used for the investigation of Urolizer precision by performing six independent BRI determinations in series. In total, 30 samples were taken for additional investigation of urine storability. Each sample was measured thrice: directly after collection, after 24-h storage at T=21 degrees C, and after 24-h cooling at T=4 degrees C. Outcomes were statistically tested for identity with regard to the immediately obtained results. Repeat measurements for evaluation of Urolizer precision revealed statistical identity of data (p-0.05). 24-h storage of urine at both tested temperatures did not significantly affect BRI (p-0.05). The pilot-run Urolizer shows high analytical reliability. The innovative analysis device may be especially suited for urologists specializing in urolithiasis treatment. The possibility for urine storage at moderate temperatures without loss of analysis quality further demonstrates the applicability of the BRI method.

  4. Detection of Ciprofloxacin in Urine through Sensitized Lanthanide Luminescence

    PubMed Central

    Singha, Subhankar; Ahn, Kyo Han

    2016-01-01

    Ciprofloxacin, a fluoroquinolone antibiotic, is widely used for the treatment of bacterial infection in humans due to its broad antibacterial spectrum. An excessive use or overdose of ciprofloxacin on the other hand can cause several adverse effects not only to humans but also to microorganisms. Unabsorbed ciprofloxacin in the body is mostly excreted through urine and finally goes to the environment, providing a drug resistance pressure on bacteria. Hence a simple and efficient detection method of ciprofloxacin is necessary, which, for example, can be used to analyze ciprofloxacin content in urine. Although ciprofloxacin itself shows inherent fluorescence, direct fluorescent detection of ciprofloxacin in raw urine sample is difficult due to autofluorescence of urine by other components. Herein we report that a Tb(III) complex of DO3A (1,4,7,10-tetraazacyclododecane-1,4,7-triacetic acid) can be efficiently sensitized by ciprofloxacin to emit luminescence separately from the urine autofluorescence wavelength region. Tb-DO3A shows excellent sensitivity with a detection limit of three parts per billion in aqueous buffer solution. Further, Tb-DO3A is used to detect ciprofloxacin with high sensitivity and selectivity in a raw urine sample without any purification or separation procedures in the concentrations ranging from 1 µg·mL−1 to 50 µg·mL−1. The direct measurement of ciprofloxacin excreted in urine may be used to control overdose of the drug. PMID:27929396

  5. High-throughput quantitative analysis by desorption electrospray ionization mass spectrometry.

    PubMed

    Manicke, Nicholas E; Kistler, Thomas; Ifa, Demian R; Cooks, R Graham; Ouyang, Zheng

    2009-02-01

    A newly developed high-throughput desorption electrospray ionization (DESI) source was characterized in terms of its performance in quantitative analysis. A 96-sample array, containing pharmaceuticals in various matrices, was analyzed in a single run with a total analysis time of 3 min. These solution-phase samples were examined from a hydrophobic PTFE ink printed on glass. The quantitative accuracy, precision, and limit of detection (LOD) were characterized. Chemical background-free samples of propranolol (PRN) with PRN-d(7) as internal standard (IS) and carbamazepine (CBZ) with CBZ-d(10) as IS were examined. So were two other sample sets consisting of PRN/PRN-d(7) at varying concentration in a biological milieu of 10% urine or porcine brain total lipid extract, total lipid concentration 250 ng/microL. The background-free samples, examined in a total analysis time of 1.5 s/sample, showed good quantitative accuracy and precision, with a relative error (RE) and relative standard deviation (RSD) generally less than 3% and 5%, respectively. The samples in urine and the lipid extract required a longer analysis time (2.5 s/sample) and showed RSD values of around 10% for the samples in urine and 4% for the lipid extract samples and RE values of less than 3% for both sets. The LOD for PRN and CBZ when analyzed without chemical background was 10 and 30 fmol, respectively. The LOD of PRN increased to 400 fmol analyzed in 10% urine, and 200 fmol when analyzed in the brain lipid extract.

  6. Evaluation of the Urine Protein/Creatinine Ratio Measured with the Dipsticks Clinitek Atlas PRO 12.

    PubMed

    Hermida, Fernando J; Soto, Sonia; Benitez, Alfonso J

    2016-01-01

    Screening for urine proteins is recommended for the detection of albuminuria in high risk groups. The aim of this study was to compare the Clinitek Atlas PRO12 reagent urine strip with quantitative methods for the determination of protein/creatinine ratio and to evaluate the usefulness of the semi-quantitative Clinitek Atlas PRO12 reagent urine strip as a tool in the early detection of albuminuria among the general population. Six hundred first morning urine specimens were collected from outpatients with various clinical conditions. The results showed that the test data for the urine dipstick Clinitek Atlas PRO12 show good agreement with the quantitative measurement of protein, creatinine and protein/creatinine ratio. In addition, this study shows that 97.2% of the samples which gave "normal" protein/creatinine ratios by the semi-quantitative method, showed albumin/creatinine ratio < 30 mg/g by the quantitative methods. Our results show that Clinitek Atlas PRO12 reagent strips can be used for the purposes of albuminuria screening in the general population.

  7. Effect of storage temperature on endogenous GHB levels in urine.

    PubMed

    LeBeau, M A; Miller, M L; Levine, B

    2001-06-15

    Because gamma-hydroxybutyrate (GHB) is an endogenous substance present in the body and is rapidly eliminated after ingestion, toxicologists investigating drug-facilitated sexual assault cases are often asked to differentiate between endogenous and exogenous levels of GHB in urine samples. This study was designed to determine the effects of storage temperature on endogenous GHB levels in urine. Specifically, it was designed to ascertain whether endogenous levels can be elevated to a range considered indicative of GHB ingestion. Urine specimens from two subjects that had not been administered exogenous GHB were collected during a 24h period and individually pooled. The pooled specimens were separated into standard sample cups and divided into three storage groups: room temperature ( approximately 25 degrees C), refrigerated (5 degrees C), and frozen (-10 degrees C). Additionally, some specimens were put through numerous freeze/thaw cycles to mimic situations that may occur if multiple laboratories analyze the same specimen. Periodic analysis of the samples revealed increases in the levels of endogenous GHB over a 6-month period. The greatest increase (up to 404%) was observed in the samples maintained at room temperature. The refrigerated specimens showed increases of 140-208%, while the frozen specimens showed smaller changes (88-116%). The specimens subjected to multiple freeze/thaw cycles mirrored specimens that had been thawed only once. None of the stored urine specimens demonstrated increases in GHB concentrations that would be consistent with exogenous GHB ingestion.

  8. Novel ELISAs for screening of the biogenic amines GABA, glycine, beta-phenylethylamine, agmatine, and taurine using one derivatization procedure of whole urine samples.

    PubMed

    Huisman, Han; Wynveen, Paul; Nichkova, Mikaela; Kellermann, Gottfried

    2010-08-01

    The inhibitory neurotransmitters GABA, glycine and agmatine and neuromodulators beta-phenylethylamine (beta-PEA) and taurine are important biogenic amines of the sympathetic and parasympathetic nervous systems in the body. Abnormalities in the metabolism of these biomarkers have been implicated in a vast number of neurological diseases. Novel competitive immunoassays, using one unique whole urine derivatization procedure applicable for all five biomarkers, have been developed. The determination of these biomarkers was highly reproducible: the coefficient of variance of inter- and intra-assay variation is between 3.9% and 9.8% for all assays. The assays show a good linearity in urine samples within the range of 100-400 mg Cr/dL and specificity when urine samples are spiked with biogenic amines. The recoveries are between 76 and 154%. The correlation between HPLC and ELISA for glycine and taurine (n = 10) showed regression coefficients of 0.97 and 0.98, respectively. An in vivo study on the urinary clearance of beta-PEA, agmatine and taurine after oral intake by healthy individuals demonstrated the specificity and clinical significance of these new immunoassays. The immunoassays are useful for clinical and basic research where a fast and accurate assay for the screening of biogenic amines in urine is required, without preclearance of the sample.

  9. Evaluation of a nested-PCR for mycobacterium tuberculosis detection in blood and urine samples.

    PubMed

    da Cruz, Heidi Lacerda Alves; de Albuquerque Montenegro, Rosana; de Araújo Lima, Juliana Falcão; da Rocha Poroca, Diogo; da Costa Lima, Juliana Figueirêdo; Maria Lapa Montenegro, Lílian; Crovella, Sergio; Charifker Schindler, Haiana

    2011-01-01

    The polymerase chain reaction (PCR) and its variations, such as the nested-PCR, have been described as promising techniques for rapid diagnosis of tuberculosis (TB). With the aim of evaluating the usefulness of a nested-PCR method on samples of blood and urine of patients suspected of tuberculosis we analyzed 192 clinical samples, using as a molecular target the insertion element IS6110 specific of M. tuberculosis genome. Nested-PCR method showed higher sensitivity in patients with extrapulmonary tuberculosis (47.8% and 52% in blood and urine) when compared to patients with the pulmonary form of the disease (sensitivity of 29% and 26.9% in blood and urine), regardless of the type of biological sample used. The nested-PCR is a rapid technique that, even if not showing a good sensitivity, should be considered as a helpful tool especially in the extrapulmonary cases or in cases where confirmatory diagnosis is quite difficult to be achieved by routine methods. The performance of PCR-based techniques should be considered and tested in future works on other types of biological specimens besides sputum, like blood and urine, readily obtainable in most cases. The improving of M. tuberculosis nested-PCR detection in TB affected patients will give the possibility of an earlier detection of bacilli thus interrupting the transmission chain of the disease.

  10. Spectrophotometric methods for the determination of urea in real samples using silver nanoparticles by standard addition and 2nd order derivative methods

    NASA Astrophysics Data System (ADS)

    Ali, Nauman; Ismail, Muhammad; Khan, Adnan; Khan, Hamayun; Haider, Sajjad; Kamal, Tahseen

    2018-01-01

    In this work, we have developed simple, sensitive and inexpensive methods for the spectrophotometric determination of urea in urine samples using silver nanoparticles (AgNPs). The standard addition and 2nd order derivative methods were adopted for this purpose. AgNPs were prepared by chemical reduction of AgNO3 with hydrazine using 1,3-di-(1H-imidazol-1-yl)-2-propanol (DIPO) as a stabilizing agent in aqueous medium. The proposed methods were based on the complexation of AgNPs with urea. Using this concept, urea in the urine samples was successfully determined spectrophotometric methods. The results showed high percent recovery with ± RSD. The recoveries of urea in the three urine samples by spectrophotometric standard addition were 99.2% ± 5.37, 96.3% ± 4.49, 104.88% ± 4.99 and that of spectrophotometric 2nd order derivative method were 115.3% ± 5.2, 103.4% ± 2.6, 105.93% ± 0.76. The results show that these methods can open doors for a potential role of AgNPs in the clinical determination of urea in urine, blood, biological, non-biological fluids.

  11. Presence of infective Epstein-Barr virus in the urine of patients with infectious mononucleosis.

    PubMed

    Landau, Z; Gross, R; Sanilevich, A; Friedmann, A; Mitrani-Rosenbaum, S

    1994-11-01

    The presence of Epstein-Barr virus (EBV) in the blood and urine of 20 patients with infectious mononucleosis (IM) was investigated together with the clinical course of the disease, and in 9 patients up to 2-7 months after recovery. EBV DNA, analyzed by the polymerase chain reaction (PCR), was detected in the blood of all 20 patients from the first sample obtained and detected between 3 to 42 days from the beginning of symptoms and up to 2-3 months after recovery. In the urine, EBV DNA was detected in 15 out of 16 (93%) patients in the first sample obtained and detected between 3 to 50 days during the clinical course of the disease. In four patients EBV DNA was detected in the urine up to 3 months after full recovery. Seventeen out of 26 (65%) urine samples including 3 which were obtained 2-7 months after recovery infected B cells as assessed by PCR. Nine out of 12 (75%) urine samples tested induced Epstein-Barr nuclear antigen (EBNA) in the infected B-cell line. In addition to the persistence of EBV in the blood of IM patients, these studies show for the first time the presence of infective EBV in the urine during the clinical course of the disease and up to 7 months after full clinical recovery.

  12. Quantitation of iothalamate in urine and plasma using liquid chromatography electrospray tandem mass spectrometry (HPLC-ESI-MS/MS).

    PubMed

    Molinaro, Ross J; Ritchie, James C

    2010-01-01

    The following chapter describes a method to measure iothalamate in plasma and urine samples using high performance liquid chromatography combined with electrospray positive ionization tandem mass spectrometry (HPLC-ESI-MS/MS). Methanol and water are spiked with the internal standard (IS) iohexol. Iothalamate is isolated from plasma after IS spiked methanol extraction and from urine by IS spiked water addition and quick-spin filtration. The plasma extractions are dried under a stream of nitrogen. The residue is reconstituted in ammonium acetate-formic acid-water. The reconstituted plasma and filtered urine are injected into the HPLC-ESI-MS/MS. Iothalamate and iohexol show similar retention times in plasma and urine. Quantification of iothalamate in the samples is made by multiple reaction monitoring using the hydrogen adduct mass transitions, from a five-point calibration curve.

  13. Performance of Copan WASP for Routine Urine Microbiology

    PubMed Central

    Quiblier, Chantal; Jetter, Marion; Rominski, Mark; Mouttet, Forouhar; Böttger, Erik C.; Keller, Peter M.

    2015-01-01

    This study compared a manual workup of urine clinical samples with fully automated WASPLab processing. As a first step, two different inocula (1 and 10 μl) and different streaking patterns were compared using WASP and InoqulA BT instrumentation. Significantly more single colonies were produced with the10-μl inoculum than with the 1-μl inoculum, and automated streaking yielded significantly more single colonies than manual streaking on whole plates (P < 0.001). In a second step, 379 clinical urine samples were evaluated using WASP and the manual workup. Average numbers of detected morphologies, recovered species, and CFUs per milliliter of all 379 urine samples showed excellent agreement between WASPLab and the manual workup. The percentage of urine samples clinically categorized as positive or negative did not differ between the automated and manual workflow, but within the positive samples, automated processing by WASPLab resulted in the detection of more potential pathogens. In summary, the present study demonstrates that (i) the streaking pattern, i.e., primarily the number of zigzags/length of streaking lines, is critical for optimizing the number of single colonies yielded from primary cultures of urine samples; (ii) automated streaking by the WASP instrument is superior to manual streaking regarding the number of single colonies yielded (for 32.2% of the samples); and (iii) automated streaking leads to higher numbers of detected morphologies (for 47.5% of the samples), species (for 17.4% of the samples), and pathogens (for 3.4% of the samples). The results of this study point to an improved quality of microbiological analyses and laboratory reports when using automated sample processing by WASP and WASPLab. PMID:26677255

  14. Influence of Freezing and Storage Procedure on Human Urine Samples in NMR-Based Metabolomics

    PubMed Central

    Rist, Manuela J.; Muhle-Goll, Claudia; Görling, Benjamin; Bub, Achim; Heissler, Stefan; Watzl, Bernhard; Luy, Burkhard

    2013-01-01

    It is consensus in the metabolomics community that standardized protocols should be followed for sample handling, storage and analysis, as it is of utmost importance to maintain constant measurement conditions to identify subtle biological differences. The aim of this work, therefore, was to systematically investigate the influence of freezing procedures and storage temperatures and their effect on NMR spectra as a potentially disturbing aspect for NMR-based metabolomics studies. Urine samples were collected from two healthy volunteers, centrifuged and divided into aliquots. Urine aliquots were frozen either at −20 °C, on dry ice, at −80 °C or in liquid nitrogen and then stored at −20 °C, −80 °C or in liquid nitrogen vapor phase for 1–5 weeks before NMR analysis. Results show spectral changes depending on the freezing procedure, with samples frozen on dry ice showing the largest deviations. The effect was found to be based on pH differences, which were caused by variations in CO2 concentrations introduced by the freezing procedure. Thus, we recommend that urine samples should be frozen at −20 °C and transferred to lower storage temperatures within one week and that freezing procedures should be part of the publication protocol. PMID:24957990

  15. Influence of Freezing and Storage Procedure on Human Urine Samples in NMR-Based Metabolomics.

    PubMed

    Rist, Manuela J; Muhle-Goll, Claudia; Görling, Benjamin; Bub, Achim; Heissler, Stefan; Watzl, Bernhard; Luy, Burkhard

    2013-04-09

    It is consensus in the metabolomics community that standardized protocols should be followed for sample handling, storage and analysis, as it is of utmost importance to maintain constant measurement conditions to identify subtle biological differences. The aim of this work, therefore, was to systematically investigate the influence of freezing procedures and storage temperatures and their effect on NMR spectra as a potentially disturbing aspect for NMR-based metabolomics studies. Urine samples were collected from two healthy volunteers, centrifuged and divided into aliquots. Urine aliquots were frozen either at -20 °C, on dry ice, at -80 °C or in liquid nitrogen and then stored at -20 °C, -80 °C or in liquid nitrogen vapor phase for 1-5 weeks before NMR analysis. Results show spectral changes depending on the freezing procedure, with samples frozen on dry ice showing the largest deviations. The effect was found to be based on pH differences, which were caused by variations in CO2 concentrations introduced by the freezing procedure. Thus, we recommend that urine samples should be frozen at -20 °C and transferred to lower storage temperatures within one week and that freezing procedures should be part of the publication protocol.

  16. A Direct Aqueous Derivatization GSMS Method for Determining Benzoylecgonine Concentrations in Human Urine.

    PubMed

    Chericoni, Silvio; Stefanelli, Fabio; Da Valle, Ylenia; Giusiani, Mario

    2015-09-01

    A sensitive and reliable method for extraction and quantification of benzoylecgonine (BZE) and cocaine (COC) in urine is presented. Propyl-chloroformate was used as derivatizing agent, and it was directly added to the urine sample: the propyl derivative and COC were then recovered by liquid-liquid extraction procedure. Gas chromatography-mass spectrometry was used to detect the analytes in selected ion monitoring mode. The method proved to be precise for BZE and COC both in term of intraday and interday analysis, with a coefficient of variation (CV)<6%. Limits of detection (LOD) were 2.7 ng/mL for BZE and 1.4 ng/mL for COC. The calibration curve showed a linear relationship for BZE and COC (r2>0.999 and >0.997, respectively) within the range investigated. The method, applied to thirty authentic samples, showed to be very simple, fast, and reliable, so it can be easily applied in routine analysis for the quantification of BZE and COC in urine samples. © 2015 American Academy of Forensic Sciences.

  17. NEW COLUMN SEPARATION METHOD FOR EMERGENCY URINE SAMPLES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxwell, S; Brian Culligan, B

    2007-08-28

    The Savannah River Site Environmental Bioassay Lab participated in the 2007 NRIP Emergency Response program administered by the National Institute for Standards and Technology (NIST) in May, 2007. A new rapid column separation method was applied directly to the NRIP 2007 emergency urine samples, with only minimal sample preparation to reduce preparation time. Calcium phosphate precipitation, previously used to pre-concentrate actinides and Sr-90 in NRIP 2006 urine and water samples, was not used for the NRIP 2007 urine samples. Instead, the raw urine was acidified and passed directly through the stacked resin columns (TEVA+TRU+SR Resins) to separate the actinides andmore » strontium from the NRIP urine samples more quickly. This improvement reduced sample preparation time for the NRIP 2007 emergency urine analyses significantly. This approach works well for small volume urine samples expected during an emergency response event. Based on initial feedback from NIST, the SRS Environmental Bioassay Lab had the most rapid analysis times for actinides and strontium-90 analyses for NRIP 2007 urine samples.« less

  18. Rapid test by liquid chromatography/tandem mass spectrometry to evaluate equine urine reactivity towards 17beta-OH steroids.

    PubMed

    Fidani, Marco; Casagni, Eleonora; Montana, Marco; Pasello, Emanuela; Pecoraro, Chiara; Gambaro, Veniero

    2006-01-01

    Bacteria frequently found in equine urine samples may cause degradation of 17beta-OH steroids. A simple liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed to evaluate the microbiological contamination of equine urine as a marker of poor storage conditions. Norethandrolone was used as the internal standard, and the linearity, sensitivity, precision and accuracy of the method were evaluated. 17beta-OH oxidation was demonstrated for testosterone, nandrolone, trenbolone and boldenone, but did not occur in alpha-epimers such as alpha-boldenone and epitestosterone, demonstrating the stereoselectivity of the reaction. A rapid test was performed by spiking one of the four 17beta-OH steroids in samples of diluted equine urine. The steroids were transformed into their respective ketones in the presence of bacterial activity. The test allows direct injection of diluted samples into the LC/MS system, without the need for prior extraction. Results show that the best method of storage is freezing at -18 degrees C. Urine specimens should be analyzed as soon as possible after thawing. This allows bacterial degradation of equine urine to be arrested temporarily, so that the urine can be used for qualitative or quantitative analysis of 17beta-OH steroids.

  19. [Cortisol/creatinine ratio in urine (UCC) of healthy cats].

    PubMed

    Zimmer, C; Reusch, C E

    2003-07-01

    In 31 healthy cats urine samples were taken to determine the cortisol/creatinine ratio (UCC) during hospitalisation and at home. The UCC of the samples, which had been taken in the clinic, was significantly higher (0-19 x 10(-6), Median 3 x 10(-6)) than the one of the samples taken at home (0-4 x 10(-6), Median 1 x 10(-6)). The parameter was neither influenced by the cat's age, sex or the fact that the cat stayed inside or outside, nor by the degree of visible agitation. Assay validation achieved good results regarding precision and accuracy of the measuring of cortisol and creatinine in the urine. The study shows that stress--caused by the visit to the veterinarian--can provoke a significant increase of UCC. Therefore, the parameter should be determined only from urine samples taken at home. Furthermore, it is important to notice that cortisol metabolites are measured in varying degree with the different assays. Therefore, it is inevitable that each laboratory generates its own reference values.

  20. Simple sampling strategy for measuring inulin renal clearance.

    PubMed

    Horio, Masaru; Imai, Enyu; Yasuda, Yoshinari; Hishida, Akira; Matsuo, Seiichi

    2009-02-01

    In the standard method of inulin clearance (Cin), three sets of serum and urine samples are collected during a 2-hour clearance period. For a practical use of this method, sampling should be the minimal number allowable while still providing enough accuracy. The aim of this study was to evaluate the validity of inulin renal clearance with assumed single urine collection with a period such as 30, 60 or 90 minutes. Inulin clearance data collected by the standard method from 737 individuals were used. Changes of serum inulin concentrations between 45 and 105 minutes after the start of the infusion were analyzed. We used first urine collection to calculate the inulin clearance with single urine collection (Cin-30 min). We assumed single urine collection for 60 or 90 minutes by combining the urine data of the consecutive 30-minute periods. Inulin clearances (Cin-60 min, Cin-90 min) were calculated from the assumed single urine collections, respectively. Serum inulin concentration did not reach equilibrium during the clearance period. It increased in subjects with low glomerular filtration rate (GFR) and decreased in subjects with normal GFR. The amount of the change was small and -0.5 +/- 12.6% in subjects with GFR over 30 ml/min per 1.73 m(2). Cin-30 min, Cin-60 min and Cin-90 min showed high correlation coefficients against Cin-ST (0.962, 0.988 and 0.998, respectively). Systemic biases in these clearances were negligible (under 1 ml/min per 1.73 m(2)). Root mean square error (RMSE) were 10.4, 5.3 and 2.3 ml/min per 1.73 m(2) for Cin-30 min, Cin-60 min and Cin-90 min, respectively. These data indicated that accuracy of inulin clearance depends on the duration of the urine collection period. Inulin clearance with a single urine collection is a convenient method. We showed that single urine collection for 30 minutes or a longer period has reasonable accuracy in calculation of inulin clearance. We propose a method of inulin clearance with single urine collection for 60 minutes.

  1. Determination of thiopental in urine sample with high-performance liquid chromatography using iodine-azide reaction as a postcolumn detection system.

    PubMed

    Zakrzewski, Robert; Ciesielski, Witold

    2005-09-25

    The reaction between iodine and azide ions induced by thiopental was utilized as a postcolumn reaction for chromatographic determination of thiopental. The method is based on the separation of thiopental on an Nova-Pak CN HP column with an acetonitrile-aqueous solution of sodium azide as a mobile phase, followed by spectrophotometric measurement of the residual iodine (lambda=350 nm) from the postcolumn iodine-azide reaction induced by thiopental after mixing an iodine solution containing iodide ions with the column effluent containing azide ions and thiopental. Chromatograms obtained for thiopental showed negative peaks as a result of the decrease in background absorbance. The detection limit (defined as S/N=3) was 20 nM (0.4 pmol injected amount) for thiopental. Calibration graphs, plotted as peak area versus concentrations, were linear from 40 nM. The elaborated method was applied to determine thiopental in urine samples. The detection limit (defined as S/N=3) was 0.025 nmol/ml urine. Calibration graphs, plotted as peak area versus concentrations, were linear from 0.05 nmol/ml urine. Authentic urine samples were analyzed, thiopental was determined at nmol/ml urine level.

  2. The effectiveness of BD Vacutainer® Plus Urinalysis Preservative Tubes in preservation of urine for chemical strip analysis and particle counting.

    PubMed

    Ekşioğlu, Merve Kaymak; Madenci, Özlem Çakır; Yücel, Nihal; Elçi, Abdullah; Turhan, Bülent; Orhan, Gani; Orçun, Asuman

    2016-01-01

    The aim of this study was to evaluate the stability of urine collected in preservative tubes for chemistry strip analyses and particle counting to determine whether the transport of urine samples with all of their constituents is possible. 275 pathologic urine specimens were included. Each urine sample was evaluated after 4, 8, 12, 24, and 48 hours of storage in BD Vacutainer(®) Plus Urinalysis Preservative (BD UAP) tubes and compared with refrigeration at 4 °C. All analyses were peformed on H-800 and FUS-200 automatic modular urine analyzers (Dirui Industry, Changchun, China). The kappa coefficients (κ), false positive (FP) and false negative (FN) rates were evaluated. κ > 0.8 was accepted as good agreement. Haemoglobin (Hb), leucocyte esterase (LE), and protein (Pro) analyses should be performed within 4 hours, whereas glucose (Glc) was stable until the end of 48 hours in both storage conditions. Nitrite (Nit) was well preserved in BD UAP tubes for 24 hours but was stable only up to 8 hours at 4 °C. Bilirubin (Bil) had very high FN rates even at 4 hours in both conditions. The particle counting showed high FN rates for white blood cells (WBC) and red blood cells (RBC), whereas squamous epithelial cells (EC) were stable up to 8 hours in both conditions. Preanalytical requirements for both urine chemical strip analyses and particle counting in a unique sample were not met in either condition. Thus, the transfer of urine samples for centralization of urinalysis is not yet feasible.

  3. Impact of collection conditions on the metabolite content of human urine samples as analyzed by liquid chromatography coupled to mass spectrometry and nuclear magnetic resonance spectroscopy.

    PubMed

    Roux, Aurélie; Thévenot, Etienne A; Seguin, François; Olivier, Marie-Françoise; Junot, Christophe

    There is a lack of comprehensive studies documenting the impact of sample collection conditions on metabolic composition of human urine. To address this issue, two experiments were performed at a 3-month interval, in which midstream urine samples from healthy individuals were collected, pooled, divided into several aliquots and kept under specific conditions (room temperature, 4 °C, with or without preservative) up to 72 h before storage at -80 °C. Samples were analyzed by high-performance liquid chromatography coupled to high-resolution mass spectrometry and bacterial contamination was monitored by turbidimetry. Multivariate analyses showed that urinary metabolic fingerprints were affected by the presence of preservatives and also by storage at room temperature from 24 to 72 h, whereas no change was observed for urine samples stored at 4 °C over a 72-h period. Investigations were then focused on 280 metabolites previously identified in urine: 19 of them were impacted by the kind of sample collection protocol in both experiments, including 12 metabolites affected by bacterial contamination and 7 exhibiting poor chemical stability. Finally, our results emphasize that the use of preservative prevents bacterial overgrowth, but does not avoid metabolite instability in solution, whereas storage at 4 °C inhibits bacterial overgrowth at least over a 72-h period and slows the chemical degradation process. Consequently, and for further LC/MS analyses, human urine samples should be kept at 4 °C if their collection is performed over 24 h.

  4. Phthalate metabolites in Norwegian mothers and children: Levels, diurnal variation and use of personal care products.

    PubMed

    Sakhi, Amrit Kaur; Sabaredzovic, Azemira; Cequier, Enrique; Thomsen, Cathrine

    2017-12-01

    Exposure to phthalates has been associated with reproductive and developmental toxicity. Data on levels of these compounds in the Norwegian population is limited. In this study, urine samples were collected from 48 mothers and their children in two counties in Norway. Eleven different phthalate metabolites originating from six commonly used phthalates in consumer products were determined. Concentrations of phthalate metabolites were significantly higher in children compared to mothers except for mono-ethyl phthalate (MEP). The mothers provided several urine samples during 24hours (h) and diurnal variation showed that the concentrations in the morning urine samples (24-8h) were significantly higher than at other time-periods for most of the phthalate metabolites. Intraclass correlation coefficients (ICCs) for 24-hour time-period were in the range of 0.49-0.81. These moderate to high ICCs indicate that one spot urine sample can be used to estimate the exposure to phthalates. Since a significant effect of time of day was observed, it is still advisable to standardize the collection time point to reduce the variation. For the mothers, the use of personal care products (PCPs) were less associated with morning urine samples than early day (8-12h) and evening (16-24h) urine samples. The use of perfume and hair products were positively associated with the urinary concentrations of low molecular weight phthalates. Use of shower soap and shampoo were positively associated with urinary concentration of di(2-ethylhexyl) phthalate (DEHP) metabolites. For children, face cream use was positively associated with phthalate metabolites in the morning samples, and hand soap use was negatively associated with concentration of urinary DEHP metabolites in afternoon/evening samples. Since different PCPs were associated with the urinary phthalate metabolites in different time-periods during a day, more than one spot urine sample might be required to study associations between urinary phthalate metabolites and the use of PCPs. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Prednisolone and prednisone neo-formation in bovine urine after sampling.

    PubMed

    Arioli, F; Casati, A; Fidani, M; Silvestri, M; Pompa, G

    2012-06-01

    The rise in the frequency of detecting prednisolone in bovine urine from northern Italy has come into focus of attention in recent years. The possibility that neo-formation of prednisolone or that prednisone may occur in urine after collection of samples was therefore investigated. Cow urine collected for official routine controls in Lombardy containing more than 80 ng/ml cortisol, and prednisolone and prednisone below the decision limit (CCα) of the method (0.4 and 0.5 ng/ml, respectively) was used. The C1-2 dehydrogenation of naturally present cortisol and cortisone was checked by incubating urine, both contaminated and uncontaminated with faeces, at 37°C and by collecting samples at 0, 1, 2, 4, 6 and 24 h. The influence of Helix pomatia juice was also investigated in order to determine whether deconjugation could influence the reliability of the results. All samples were analysed by HPLC-MS3 for the presence of cortisol, cortisone, prednisolone and prednisone in negative electrospray ionisation mode, utilising the consecutive reaction monitoring of product ions derived from the formate molecular adduct ([M+HCOO]-). The observed neo-formation of prednisolone shows that inappropriate temperatures in sample storage and processing can result in an incorrect accusation of non-compliance. The faecal contamination of urine, performed with the aim to mimic a collection conducted without the necessary care, moreover, evoked a high increase in prednisolone concentration in two out of seven animals. Moreover, H. pomatia juice had no significant effect on the prednisolone concentration, indicating that this corticosteroid is present in its free form in cow urine.

  6. Creatine transporter deficiency: prevalence among patients with mental retardation and pitfalls in metabolite screening.

    PubMed

    Arias, Angela; Corbella, Marc; Fons, Carmen; Sempere, Angela; García-Villoria, Judit; Ormazabal, Aida; Poo, Pilar; Pineda, Mercé; Vilaseca, María Antonia; Campistol, Jaume; Briones, Paz; Pàmpols, Teresa; Salomons, Gajja S; Ribes, Antonia; Artuch, Rafael

    2007-11-01

    To report the prevalence of creatine transporter deficiency in males with mental retardation and to study whether a protein-rich food intake might be a potential diagnostic pitfall. We determined creatine/creatinine ratio in urine samples from 1600 unrelated male patients with mental retardation and/or autism. Urine creatine was analyzed by HPLC-MS/MS. Thirty-three of 1600 cases showed increased urine creatine/creatinine ratio. Four out of these thirty-three cases were definitively diagnosed with creatine transporter deficiency, while the other 29 were false positive results. Significantly higher values were observed for urine Cr/Crn ratio in healthy volunteers after a meal based on beef or oily fish as compared to eggs, pasta or salad (Wilcoxon test: p<0.005). False positive results may be observed in biochemical screening for creatine transporter deficiency, and they may be due to intake of meals rich in creatine prior to urine samples analysis.

  7. Detection of Methamphetamine and Morphine in Urine and Saliva Using Excitation-Emission Matrix Fluorescence and a Second-Order Calibration Algorithm

    NASA Astrophysics Data System (ADS)

    Xu, B. Y.; Ye, Y.; Liao, L. C.

    2016-07-01

    A new method was developed to determine the methamphetamine and morphine concentrations in urine and saliva based on excitation-emission matrix fluorescence coupled to a second-order calibration algorithm. In the case of single-drug abuse, the results showed that the average recoveries of methamphetamine and morphine were 95.3 and 96.7% in urine samples, respectively, and 98.1 and 106.2% in saliva samples, respectively. The relative errors were all below 5%. The simultaneous determination of methamphetamine and morphine in urine using two second-order algorithms was also investigated. Satisfactory results were obtained with a self-weighted alternating trilinear decomposition algorithm. The root-mean-square errors of the predictions were 0.540 and 0.0382 μg/mL for methamphetamine and morphine, respectively. The limits of detection of the proposed methods were very low and sufficient for studying methamphetamine and morphine in urine.

  8. Doping control study of AICAR in post-race urine and plasma samples from horses.

    PubMed

    Wong, Jenny K Y; Kwok, Wai Him; Chan, George H M; Choi, Timmy L S; Ho, Emmie N M; Jaubert, Murielle; Bailly-Chouriberry, Ludovic; Bonnaire, Yves; Cawley, Adam; Ming Williams, H; Keledjian, John; Brooks, Lydia; Chambers, Adam; Lin, Yuanyuan; Wan, Terence S M

    2017-09-01

    Acadesine, 5-aminoimidazole-4-carboxamide-1-β-D-ribofuranoside, commonly known as AICAR, is a naturally occurring adenosine monophosphate-activated protein kinase (AMPK) activator in many mammals, including humans and horses. AICAR has attracted considerable attention recently in the field of doping control because of a study showing the enhancement of endurance performance in unexercised or untrained mice, resulting in the term 'exercise pill'. Its use has been classified as gene doping by the World Anti-Doping Agency (WADA), and since it is endogenous, it may only be possible to control deliberate administration of AICAR to racehorses after establishment of an appropriate threshold. Herein we report our studies of AICAR in post-race equine urine and plasma samples including statistical studies of AICAR concentrations determined from 1,470 urine samples collected from thoroughbreds and standardbreds and analyzed in Australia, France, and Hong Kong. Quantification methods in equine urine and plasma using liquid chromatography-mass spectrometry were developed by the laboratories in each country. An exchange of spiked urine and plasma samples between the three countries was conducted, confirming no significant differences in the methods. However, the concentration of AICAR in plasma was found to increase upon haemolysis of whole blood samples, impeding the establishment of a suitable threshold in equine plasma. A possible urine screening cut-off at 600 ng/mL for the control of AICAR in racehorses could be considered for adoption. Application of the proposed screening cut-off to urine samples collected after intravenous administration of a small dose (2 g) of AICAR to a mare yielded a short detection time of approximately 4.5 h. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  9. Estimation of D-Arabinose by Gas Chromatography/Mass Spectrometry as Surrogate for Mycobacterial Lipoarabinomannan in Human Urine

    PubMed Central

    De, Prithwiraj; Amin, Anita G.; Valli, Eloise; Perkins, Mark D.; McNeil, Michael; Chatterjee, Delphi

    2015-01-01

    Globally, tuberculosis is slowly declining each year and it is estimated that 37 million lives were saved between 2000 and 2013 through effective diagnosis and treatment. Currently, diagnosis relies on demonstration of the bacteria, Mycobacterium tuberculosis (Mtb), in clinical specimens by serial sputum microscopy, culture and molecular testing. Commercial immunoassay lateral flow kits developed to detect Mtb lipoglycan lipoarabinomannan (LAM) in urine as a marker of active TB exhibit poor sensitivity, especially in immunocompetent individuals, perhaps due to low abundance of the analyte. Our present study was designed to develop methods to validate the presence of LAM in a quantitative fashion in human urine samples obtained from culture-confirmed TB patients. Herein we describe, a consolidated approach for isolating LAM from the urine and quantifying D-arabinose as a proxy for LAM, using Gas Chromatography/Mass Spectrometry. 298 urine samples obtained from a repository were rigorously analyzed and shown to contain varying amounts of LAM-equivalent ranging between ~10–40 ng/mL. To further substantiate that D-arabinose detected in the samples originated from LAM, tuberculostearic acid, the unique 10-methyloctadecanoic acid present at the phosphatidylinositol end of LAM was also analyzed in a set of samples and found to be present confirming that the D-arabinose was indeed derived from LAM. Among the 144 samples from culture-negative TB suspects, 30 showed presence of D-arabinose suggesting another source of the analyte, such as disseminated TB or from non-tuberculosis mycobacterium. Our work validates that LAM is present in the urine samples of culture-positive patients in small but readily detectable amounts. The study further substantiates LAM in urine as a powerful biomarker for active tuberculosis. PMID:26633829

  10. Mutagenicity of urine from individuals exposed to LPG combustion products.

    PubMed

    Yin, X J; Liu, J Z; Kong, X H; Chu, J H; Wang, H; Xiao, Z X

    1998-09-01

    The mutagenicity of urine from individuals exposed to the combustion products of liquefied petroleum gas (LPG) was detected with Salmonella typhimurium TA98 and its newly developed derivatives YG1021 (nitroreductase overproducing) and YG1024 (O-acetyltransferase overproducing). The detection showed significantly increased mutagenicity for the two YG strains and increased positive rates for all three strains in the presence of both rat liver S9 and beta-glucuronidase. Further analysis demonstrated that urine samples taken from smoking and non-smoking exposed individuals exhibited significantly higher mutagenic potency (revertants/10 microliters urine concentrate) than their corresponding controls. These results indicate that the increased urine mutagenicity is caused by the exposure to LPG combustion products or smoking. The mutagenic potency of urine samples of all exposed individuals tested with YG1024 was found to be about 7 times higher than with TA98. The difference in mutagenic potency was smaller for the same samples when comparison was made between YG1021 and TA98. This suggests that the mutagenic compounds present in the urine samples contain mainly aromatic compounds as glucuronide conjugates. Our results demonstrate that YG1024 is more sensitive than TA98 in detecting the mutagenicity of these samples. In addition, no significant difference in the mutagenic potency between the 'pure' exposed (non-smokers') and the 'pure' smokers' (unexposed) samples was found in all three tester strains. This might mean that the exposure extent of mutagens/carcinogens in LPG combustion products for exposed individuals roughly corresponds to the smoking level of smokers who smoke 20-40 cigarettes per day. Furthermore, the results also suggest that synergism might exist in the mutagenic effects of exposure to LPG combustion products and cigarette smoking.

  11. A rapid magnetic particle-based enzyme immunoassay for human cytomegalovirus glycoprotein B quantification.

    PubMed

    Pires, F; Arcos-Martinez, M Julia; Dias-Cabral, A Cristina; Vidal, Juan C; Castillo, Juan R

    2018-04-17

    Human cytomegalovirus (HCMV) is a herpes virus that can cause severe infections. Still, the available methods for its diagnostic have the main disadvantage of requiring long time to be performed. In this work, a simple magnetic particle-based enzyme immunoassay (mpEIA) for the quantification of glycoprotein B of Human cytomegalovirus (gB-HCMV) in urine samples is proposed. The immunosensor scheme is based on the analyte protein gB-HCMV sandwiched between a primary monoclonal antibody, (MBs-PrG-mAb1), and a secondary anti-gB-HCMV antibody labelled with Horseradish peroxidase (Ab2-HRP) to allow spectrophotometric detection. The mpEIA analytical performance was tested in urine samples, showing a linear dependence between gB-HCMV concentration and the absorbance signal at 450 nm in a range of concentrations from 90 to 700 pg mL -1 . The calculated detection limits for gB-HCMV were 90 ± 2 pg mL -1 and the RSD was about 6.7% in urine samples. The immunosensor showed good selectivity against other viruses from Herpesviridae family, namely varicella zoster and Epstein Barr viruses. The recoveries of spiked human urine samples at 0.30-0.50 ng mL -1 concentration levels of gB-HCMV ranged between 91 to 105%. The proposed mpEIA method was validated following the guidelines of the European Medicines Agency (EMEA-2014), and allows rapid, successful and easy quantification of gB-HCMV in urine samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Diagnostic Accuracy of Urine Protein/Creatinine Ratio Is Influenced by Urine Concentration

    PubMed Central

    Yang, Chih-Yu; Chen, Fu-An; Chen, Chun-Fan; Liu, Wen-Sheng; Shih, Chia-Jen; Ou, Shuo-Ming; Yang, Wu-Chang; Lin, Chih-Ching; Yang, An-Hang

    2015-01-01

    Background The usage of urine protein/creatinine ratio to estimate daily urine protein excretion is prevalent, but relatively little attention has been paid to the influence of urine concentration and its impact on test accuracy. We took advantage of 24-hour urine collection to examine both urine protein/creatinine ratio (UPCR) and daily urine protein excretion, with the latter as the reference standard. Specific gravity from a concomitant urinalysis of the same urine sample was used to indicate the urine concentration. Methods During 2010 to 2014, there were 540 adequately collected 24h urine samples with protein concentration, creatinine concentration, total volume, and a concomitant urinalysis of the same sample. Variables associated with an accurate UPCR estimation were determined by multivariate linear regression analysis. Receiver operating characteristic (ROC) curves were generated to determine the discriminant cut-off values of urine creatinine concentration for predicting an accurate UPCR estimation in either dilute or concentrated urine samples. Results Our findings indicated that for dilute urine, as indicated by a low urine specific gravity, UPCR is more likely to overestimate the actual daily urine protein excretion. On the contrary, UPCR of concentrated urine is more likely to result in an underestimation. By ROC curve analysis, the best cut-off value of urine creatinine concentration for predicting overestimation by UPCR of dilute urine (specific gravity ≦ 1.005) was ≦ 38.8 mg/dL, whereas the best cut-off values of urine creatinine for predicting underestimation by UPCR of thick urine were ≧ 63.6 mg/dL (specific gravity ≧ 1.015), ≧ 62.1 mg/dL (specific gravity ≧ 1.020), ≧ 61.5 mg/dL (specific gravity ≧ 1.025), respectively. We also compared distribution patterns of urine creatinine concentration of 24h urine cohort with a concurrent spot urine cohort and found that the underestimation might be more profound in single voided samples. Conclusions The UPCR in samples with low or high specific gravity is more likely to overestimate or underestimate actual daily urine protein amount, respectively, especially in a dilute urine sample with its creatinine below 38.8 mg/dL or a concentrated sample with its creatinine above 61.5 mg/dL. In particular, UPCR results should be interpreted with caution in cases that involve dilute urine samples because its overestimation may lead to an erroneous diagnosis of proteinuric renal disease or an incorrect staging of chronic kidney disease. PMID:26353117

  13. Diagnostic Accuracy of Urine Protein/Creatinine Ratio Is Influenced by Urine Concentration.

    PubMed

    Yang, Chih-Yu; Chen, Fu-An; Chen, Chun-Fan; Liu, Wen-Sheng; Shih, Chia-Jen; Ou, Shuo-Ming; Yang, Wu-Chang; Lin, Chih-Ching; Yang, An-Hang

    2015-01-01

    The usage of urine protein/creatinine ratio to estimate daily urine protein excretion is prevalent, but relatively little attention has been paid to the influence of urine concentration and its impact on test accuracy. We took advantage of 24-hour urine collection to examine both urine protein/creatinine ratio (UPCR) and daily urine protein excretion, with the latter as the reference standard. Specific gravity from a concomitant urinalysis of the same urine sample was used to indicate the urine concentration. During 2010 to 2014, there were 540 adequately collected 24h urine samples with protein concentration, creatinine concentration, total volume, and a concomitant urinalysis of the same sample. Variables associated with an accurate UPCR estimation were determined by multivariate linear regression analysis. Receiver operating characteristic (ROC) curves were generated to determine the discriminant cut-off values of urine creatinine concentration for predicting an accurate UPCR estimation in either dilute or concentrated urine samples. Our findings indicated that for dilute urine, as indicated by a low urine specific gravity, UPCR is more likely to overestimate the actual daily urine protein excretion. On the contrary, UPCR of concentrated urine is more likely to result in an underestimation. By ROC curve analysis, the best cut-off value of urine creatinine concentration for predicting overestimation by UPCR of dilute urine (specific gravity ≦ 1.005) was ≦ 38.8 mg/dL, whereas the best cut-off values of urine creatinine for predicting underestimation by UPCR of thick urine were ≧ 63.6 mg/dL (specific gravity ≧ 1.015), ≧ 62.1 mg/dL (specific gravity ≧ 1.020), ≧ 61.5 mg/dL (specific gravity ≧ 1.025), respectively. We also compared distribution patterns of urine creatinine concentration of 24h urine cohort with a concurrent spot urine cohort and found that the underestimation might be more profound in single voided samples. The UPCR in samples with low or high specific gravity is more likely to overestimate or underestimate actual daily urine protein amount, respectively, especially in a dilute urine sample with its creatinine below 38.8 mg/dL or a concentrated sample with its creatinine above 61.5 mg/dL. In particular, UPCR results should be interpreted with caution in cases that involve dilute urine samples because its overestimation may lead to an erroneous diagnosis of proteinuric renal disease or an incorrect staging of chronic kidney disease.

  14. Modulated Raman spectroscopy for enhanced identification of bladder tumor cells in urine samples.

    PubMed

    Canetta, Elisabetta; Mazilu, Michael; De Luca, Anna Chiara; Carruthers, Antonia E; Dholakia, Kishan; Neilson, Sam; Sargeant, Harry; Briscoe, Tina; Herrington, C Simon; Riches, Andrew C

    2011-03-01

    Standard Raman spectroscopy (SRS) is a noninvasive technique that is used in the biomedical field to discriminate between normal and cancer cells. However, the presence of a strong fluorescence background detracts from the use of SRS in real-time clinical applications. Recently, we have reported a novel modulated Raman spectroscopy (MRS) technique to extract the Raman spectra from the background. In this paper, we present the first application of MRS to the identification of human urothelial cells (SV-HUC-1) and bladder cancer cells (MGH) in urine samples. These results are compared to those obtained by SRS. Classification using the principal component analysis clearly shows that MRS allows discrimination between Raman spectra of SV-HUC-1 and MGH cells with high sensitivity (98%) and specificity (95%). MRS is also used to distinguish between SV-HUC-1 and MGH cells after exposure to urine for up to 6 h. We observe a marked change in the MRS of SV-HUC-1 and MGH cells with time in urine, indicating that the conditions of sample collection will be important for the application of this methodology to clinical urine samples.

  15. Monitoring of PAEMs and beta-agonists in urine for a small group of experimental subjects and PAEs and beta-agonists in drinking water consumed by the same subjects.

    PubMed

    Liou, Saou-Hsing; Yang, Gordon C C; Wang, Chih-Lung; Chiu, Yu-Han

    2014-07-30

    This 5-month study contains two parts: (1) to monitor the concentrations of 11 phthalate esters metabolites (PAEMs) and two beta-agonists in human urine samples collected from a small group of consented participants including 16 females and five males; and (2) to analyze the residues of phthalate esters (PAEs) and beta-agonists in various categories of drinking water consumed by the same group of subjects. Each category of human urine and drinking water had 183 samples of its own. The analytical results showed that nine PAEMs were detected in human urine and eight PAEs were detected in drinking water samples. It was found that average concentrations of PAEMs increased as the age increased, but no significant difference between sexes. Further, using the principal component analysis, the loadings of age effect were found to be two times greater than that of gender effect in terms of four DEHP metabolites. Regarding beta-agonists of concern (i.e., ractopamine and salbutamol), they were neither detected in human urine nor drinking water samples in this study. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Determination of the GABA analogue succinic semialdehyde in urine and cerebrospinal fluid by dinitrophenylhydrazine derivatization and liquid chromatography-tandem mass spectrometry: application to SSADH deficiency.

    PubMed

    Struys, E A; Jansen, E E W; Gibson, K M; Jakobs, C

    2005-01-01

    Succinic semialdehyde (SSA) accumulates in the inborn error of meta- bolism succinic semialdehyde dehydrogenase deficiency owing to impaired enzymatic conversion to succinic acid. We developed a stable-isotope dilution liquid chromato- graphy-tandem mass spectrometry method for the determination of SSA in urine and cerebrospinal fluid samples. Stable-isotope-labelled [13C4]SSA, serving as internal standard, was prepared by reaction of ninhydrin with L-[13C5]glutamic acid. SSA in body fluids was converted to its dinitrophenylhydrazine (DNPH) derivative, without sample purification prior to the derivatization procedure. The DNPH derivative of SSA was injected onto a C18 analytical column and chromatography was performed by isocratic elution. Detection was accomplished by tandem mass spectrometry operating in the negative multiple-reaction monitoring mode. The limit of detection was 10 nmol/L and the calibration curves over the range 0-500 pmol of SSA showed good linearity (r2 > 0.99). The intra-day coefficient of variation (n = 10) for urine was 2.7% and inter-day coefficient of variation (n = 5) for urine was 8.5%. The average recoveries performed on two levels by enriching urine and cerebrospinal fluid samples ranged between 85 and 115%, with coefficients of variation < 8%. The method enabled the first determination of normal values for SSA in urine and pathological values of SSA in urine and cerebrospinal fluid samples derived from patients with succinic semialdehyde dehydrogenase deficiency.

  17. Analysis of cannabis in oral fluid specimens by GC-MS with automatic SPE.

    PubMed

    Choi, Hyeyoung; Baeck, Seungkyung; Kim, Eunmi; Lee, Sooyeun; Jang, Moonhee; Lee, Juseon; Choi, Hwakyung; Chung, Heesun

    2009-12-01

    Methamphetamine (MA) is the most commonly abused drug in Korea, followed by cannabis. Traditionally, MA analysis is carried out on both urine and hair samples and cannabis analysis in urine samples only. Despite the fact that oral fluid has become increasingly popular as an alternative specimen in the field of driving under the influence of drugs (DUID) and work place drug testing, its application has not been expanded to drug analysis in Korea. Oral fluid is easy to collect and handle and can provide an indication of recent drug abuse. In this study, we present an analytical method using GC-MS to determine tetrahydrocannabinol (THC) and its main metabolite 11-nor-delta9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) in oral fluid. The validated method was applied to oral fluid samples collected from drug abuse suspects and the results were compared with those in urine. The stability of THC and THC-COOH in oral fluid stored in different containers was also investigated. Oral fluid specimens from 12 drug abuse suspects, submitted by the police, were collected by direct expectoration. The samples were screened with microplate ELISA. For confirmation they were extracted using automated SPE with mixed-mode cation exchange cartridge, derivatized and analyzed by GC-MS using selective ion monitoring (SIM). The concentrations ofTHC and THC-COOH in oral fluid showed a large variation and the results from oral fluid and urine samples from cannabis abusers did not show any correlation. Thus, detailed information about time interval between drug use and sample collection is needed to interpret the oral fluid results properly. In addition, further investigation about the detection time window ofTHC and THC-COOH in oral fluid is required to substitute oral fluid for urine in drug testing.

  18. Soy isoflavone metabolism in cats compared with other species: Urinary metabolite concentrations and glucuronidation by liver microsomes

    PubMed Central

    Redmon, Joanna M.; Shrestha, Binu; Cerundolo, Rosario; Court, Michael H.

    2016-01-01

    Soybean is a common source of protein in many pet foods. Slow glucuronidation of soy-derived isoflavones in cats has been hypothesized to result in accumulation with adverse health consequences. Here we evaluated species’ differences in soy isoflavone glucuronidation using urine samples from cats and dogs fed a soy-based diet and liver microsomes from cats compared with microsomes from 12 other species.Significant concentrations of conjugated (but not unconjugated) genistein, daidzein, and glycitein, and the gut microbiome metabolites, dihydrogenistein and dihydrodaidzein were found in cat and dog urine samples. Substantial amounts of conjugated equol were also found in cat urine but not in dog urine.β-glucuronidase treatment showed that all these compounds were significantly glucuronidated in dog urine while only daidzein (11%) and glycitein (37%) showed any glucuronidation in cat urine suggesting that alternate metabolic pathways including sulfation predominate in cats.Glucuronidation rates of genistein, daidzein, and equol by cat livers were consistently ranked within the lowest three out of 13 species’ livers evaluated. Ferret and mongoose livers were also ranked in the lowest four species.Our results demonstrate that glucuronidation is a minor pathway for soy isoflavone metabolism in cats compared with most other species. PMID:26366946

  19. Soy isoflavone metabolism in cats compared with other species: urinary metabolite concentrations and glucuronidation by liver microsomes.

    PubMed

    Redmon, Joanna M; Shrestha, Binu; Cerundolo, Rosario; Court, Michael H

    2016-01-01

    1. Soybean is a common source of protein in many pet foods. Slow glucuronidation of soy-derived isoflavones in cats has been hypothesized to result in accumulation with adverse health consequences. Here, we evaluated species' differences in soy isoflavone glucuronidation using urine samples from cats and dogs fed a soy-based diet and liver microsomes from cats compared with microsomes from 12 other species. 2. Significant concentrations of conjugated (but not unconjugated) genistein, daidzein and glycitein, and the gut microbiome metabolites, dihydrogenistein and dihydrodaidzein, were found in cat and dog urine samples. Substantial amounts of conjugated equol were also found in cat urine but not in dog urine. 3. β-Glucuronidase treatment showed that all these compounds were significantly glucuronidated in dog urine while only daidzein (11%) and glycitein (37%) showed any glucuronidation in cat urine suggesting that alternate metabolic pathways including sulfation predominate in cats. 4. Glucuronidation rates of genistein, daidzein and equol by cat livers were consistently ranked within the lowest 3 out of 13 species' livers evaluated. Ferret and mongoose livers were also ranked in the lowest four species. 5. Our results demonstrate that glucuronidation is a minor pathway for soy isoflavone metabolism in cats compared with most other species.

  20. Diagnosis of diabetes mellitus at the hospital of Venice in 1863.

    PubMed

    Dall'Olio, G; Dorizzi, R M

    2000-07-01

    In 1674 Thomas Willis reported that the presence of urine 'as sweet as honey' was the pathognomonic sign of diabetes mellitus. In the 19th Century several reactions for the detection of glucose in urine were proposed and glucose measurement became common in the laboratories that were being set up in Europe. A case of diabetes mellitus, diagnosed by Namias, the head of the Women's Section of the Medicine Department of Venice Hospital, was reported in 1863 in the 'Giornale Veneto di Scienze Mediche' which contains clinical and laboratory information. A 34-year-old woman was admitted to the hospital for polydypsia, polyuria, bulimia and fatigue. Urine was weighed for 2 months (2-10 kgday(-1)) and the relative density ranged from 1.045 to 1.038. Glucose was measured in the urine using Moore, Trommer and Fehling reagents. A few days after admission a urine sample showed 7.69 parts/100 parts of urine and a blood sample showed 547 mg of glucose/100 g of serum. The assays were carried out in the Clinical Laboratory of Venice Hospital, founded in 1863, directed by Giovanni Bizio, one of the first chemists who graduated at Padua University. In 1863 chemical analyses were commonly carried out in Venice as in the other parts of Habsburg empire.

  1. Arsenic in the breast milk of lactating women in arsenic-affected areas of West Bengal, India and its effect on infants.

    PubMed

    Samanta, Gautam; Das, Dipankar; Mandal, Badal K; Chowdhury, Tarit Roy; Chakraborti, Dipankar; Pal, Arup; Ahamed, Sad

    2007-10-01

    Two hundred and twenty-six breast milk samples were collected from lactating women from 3 blocks of North-24 Paragans, one of the arsenic-affected districts of West Bengal, India. Out of 226 samples, only in 39 samples arsenic was detected. Urine, hair, and nail samples were also analyzed to know the arsenic body burden of the lactating women. Arsenic in drinking water was also analyzed. Principle component analysis (PCA) revealed that hair and nail arsenic was highly correlated with water arsenic concentrations, whereas arsenic in urine and breast milk did not cluster with water arsenic. Our present study indicated that among the lactating women who had high arsenic body burden and arsenical skin lesions, they had elevated level of arsenic in their breast milk. Arsenic in hair, nails, and urine samples of infants were analyzed, and the results showed significantly high-body burden of infants in those areas. PCA showed the age-dependent relationship between the hair and nail arsenic concentrations of the mothers and their babies.

  2. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF URINE SAMPLES (SOP-2.14)

    EPA Science Inventory

    This SOP describes the method for collecting urine samples from the study participants (children and their primary caregivers). Urine samples will be approximate 48-hr collections, collected as spot urine samples accumulated over the 48-hr sampling period. If the household or da...

  3. Porphyrins - urine test

    MedlinePlus

    Urine uroporphyrin; Urine coproporphyrin; Porphyria - uroporphyrin ... After you provide a urine sample, it is tested in the lab. This is called a random urine sample. If needed, your health care provider ...

  4. Human and methodological sources of variability in the measurement of urinary 8-oxo-7,8-dihydro-2'-deoxyguanosine.

    PubMed

    Barregard, Lars; Møller, Peter; Henriksen, Trine; Mistry, Vilas; Koppen, Gudrun; Rossner, Pavel; Sram, Radim J; Weimann, Allan; Poulsen, Henrik E; Nataf, Robert; Andreoli, Roberta; Manini, Paola; Marczylo, Tim; Lam, Patricia; Evans, Mark D; Kasai, Hiroshi; Kawai, Kazuaki; Li, Yun-Shan; Sakai, Kazuo; Singh, Rajinder; Teichert, Friederike; Farmer, Peter B; Rozalski, Rafal; Gackowski, Daniel; Siomek, Agnieszka; Saez, Guillermo T; Cerda, Concha; Broberg, Karin; Lindh, Christian; Hossain, Mohammad Bakhtiar; Haghdoost, Siamak; Hu, Chiung-Wen; Chao, Mu-Rong; Wu, Kuen-Yuh; Orhan, Hilmi; Senduran, Nilufer; Smith, Raymond J; Santella, Regina M; Su, Yali; Cortez, Czarina; Yeh, Susan; Olinski, Ryszard; Loft, Steffen; Cooke, Marcus S

    2013-06-20

    Urinary 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodG) is a widely used biomarker of oxidative stress. However, variability between chromatographic and ELISA methods hampers interpretation of data, and this variability may increase should urine composition differ between individuals, leading to assay interference. Furthermore, optimal urine sampling conditions are not well defined. We performed inter-laboratory comparisons of 8-oxodG measurement between mass spectrometric-, electrochemical- and ELISA-based methods, using common within-technique calibrants to analyze 8-oxodG-spiked phosphate-buffered saline and urine samples. We also investigated human subject- and sample collection-related variables, as potential sources of variability. Chromatographic assays showed high agreement across urines from different subjects, whereas ELISAs showed far more inter-laboratory variation and generally overestimated levels, compared to the chromatographic assays. Excretion rates in timed 'spot' samples showed strong correlations with 24 h excretion (the 'gold' standard) of urinary 8-oxodG (rp 0.67-0.90), although the associations were weaker for 8-oxodG adjusted for creatinine or specific gravity (SG). The within-individual excretion of 8-oxodG varied only moderately between days (CV 17% for 24 h excretion and 20% for first void, creatinine-corrected samples). This is the first comprehensive study of both human and methodological factors influencing 8-oxodG measurement, providing key information for future studies with this important biomarker. ELISA variability is greater than chromatographic assay variability, and cannot determine absolute levels of 8-oxodG. Use of standardized calibrants greatly improves intra-technique agreement and, for the chromatographic assays, importantly allows integration of results for pooled analyses. If 24 h samples are not feasible, creatinine- or SG-adjusted first morning samples are recommended.

  5. Effect of freeze/thaw cycles on several biomarkers in urine from patients with kidney disease.

    PubMed

    Zhang, Yinan; Luo, Yi; Lu, Huijuan; Wang, Niansong; Shen, Yixie; Chen, Ruihua; Fang, Pingyan; Yu, Hong; Wang, Congrong; Jia, Weiping

    2015-04-01

    Urine samples were collected from eleven randomly selected patients with kidney disease, including diabetic nephropathy, chronic nephritis, and nephritic syndrome. Urine samples were treated with one of four protocols for freezing and thawing: freeze directly and thaw directly; freeze directly and thaw by temperature gradient; freeze by temperature gradient and thaw directly; and freeze by temperature gradient and thaw by temperature gradient. After one to six freeze/thaw cycles at -20°C or -80°C, different biomarkers showed differential stabilities. The concentrations of total protein, calcium, and potassium did not change significantly after five freeze/thaw cycles at either -20°C or -80°C. Albumin could only sustain three freeze/thaw cycles at -20°C before it started to degrade. We recommend that urine be stored at -80°C as albumin and the organic ions could sustain five and six freeze/thaw cycles, respectively, using the simple "direct freeze and direct thaw" protocol. Furthermore, in most cases, gradient freeze/thaw cycles are not necessary for urine sample storage.

  6. Introduction of sample tubes with sodium azide as a preservative for ethyl glucuronide in urine.

    PubMed

    Luginbühl, Marc; Weinmann, Wolfgang; Al-Ahmad, Ali

    2017-09-01

    Ethyl glucuronide (EtG) is a direct alcohol marker, which is widely used for clinical and forensic applications, mainly for abstinence control. However, the instability of EtG in urine against bacterial degradation or the post-collectional synthesis of EtG in contaminated samples may cause false interpretation of EtG results in urine samples. This study evaluates the potential of sodium azide in tubes used for urine collection to hinder degradation of ethyl glucuronide by bacterial metabolism taking place during growth of bacterial colonies. The tubes are part of a commercial oral fluid collection device. The sampling system was tested with different gram-positive and gram-negative bacterial species previously observed in urinary tract infections, such as Escherichia coli, Staphylococcus aureus, Enterecoccus faecalis, Staphylococcus epidermidis, Klebsiella pneumoniae, Enterobacter cloacae, and Pseudomonas aeruginosa. Inhibition of bacterial growth by sodium azide, resulting in lower numbers of colony forming units compared to control samples, was observed for all tested bacterial species. To test the prevention of EtG degradation by the predominant pathogen in urinary tract infection, sterile-filtered urine and deficient medium were spiked with EtG, and inoculated with E. coli prior to incubation for 4 days at 37 °C in tubes with and without sodium azide. Samples were collected every 24 hours, during four consecutive days, whereby the colony forming units (CFU) were counted on Columbia blood agar plates, and EtG was analyzed by LC-MS/MS. As expected, EtG degradation was observed when standard polypropylene tubes were used for the storage of contaminated samples. However, urine specimens collected in sodium azide tubes showed no or very limited bacterial growth and no EtG degradation. As a conclusion, sodium azide is useful to reduce bacterial growth of gram-negative and gram-positive bacteria. It inhibits the degradation of EtG by E. coli and can be used for the stabilization of EtG in urine samples.

  7. 1-Hydroxypyrene concentrations in first morning voids and 24-h composite urine: intra- and inter-individual comparisons.

    PubMed

    Han, In-Kyu; Duan, Xiaoli; Zhang, Lin; Yang, Hongbiao; Rhoads, George G; Wei, Fusheng; Zhang, Junfeng

    2008-09-01

    Urinary 1-hydroxypyrene (1-OHP) has been suggested as an exposure biomarker for polycyclic aromatic hydrocarbons (PAHs). However, it remains unknown whether a first morning urine sample can be used to reflect average exposure. In this paper, we examine intra-individual differences and inter-individual associations between first morning voids and 24-h composite urine samples. The analysis was performed using data collected from 100 adults who had a wide range of PAH exposure due to differences in their occupation, e.g., coke oven workers vs. non-coke oven workers. For each subject, all the urine voids within each of two 24-h measurement periods were collected. Results showed a significant (40% to 62%) intra-individual difference between first morning voids and 24-h urinary 1-OHP concentrations (in ng/ml urine). Creatinine adjustments of 1-OHP concentrations (in micromol/mol urinary creatinine) reduced the intra-individual difference by approximately 10%. Across all the subjects, a high overall correlation (r=0.76) was observed between first morning and 24-h average 1-OHP concentrations. Work environment and sampling season were found to significantly affect the relationship between first morning and 24-h 1-OHP concentrations. An increase of 1 ng/ml of first morning urinary 1-OHP predicted an increase of 0.5 and 0.25 ng/ml of 24-h urinary 1-OHP for coke oven workers and non-coke oven workers, respectively. Data collected in a winter season showed a higher correlation between first morning and 24-h concentrations than data collected in a fall season. Creatinine adjustments did not significantly improve overall correlations between first morning void and 24-h measurements, but increased total variances for 24-h urines explained by first morning urines in coke workers.

  8. Low-power, low-cost urinalysis system with integrated dipstick evaluation and microscopic analysis.

    PubMed

    Smith, Gennifer T; Li, Linkai; Zhu, Yue; Bowden, Audrey K

    2018-06-21

    We introduce a coupled dipstick and microscopy device for analyzing urine samples. The device is capable of accurately assessing urine dipstick results while simultaneously imaging the microscopic contents within the sample. We introduce a long working distance, cellphone-based microscope in combination with an oblique illumination scheme to accurately visualize and quantify particles within the urine sample. To facilitate accurate quantification, we couple the imaging set-up with a power-free filtration system. The proposed device is reusable, low-cost, and requires very little power. We show that results obtained with the proposed device and custom-built app are consistent with those obtained with the standard clinical protocol, suggesting the potential clinical utility of the device.

  9. High-throughput analysis of amphetamines in blood and urine with online solid-phase extraction-liquid chromatography-tandem mass spectrometry.

    PubMed

    Fernández, María del Mar Ramírez; Wille, Sarah M R; Samyn, Nele; Wood, Michelle; López-Rivadulla, Manuel; De Boeck, Gert

    2009-01-01

    An automated online solid-phase extraction-liquid chromatography-tandem mass spectrometry (SPE-LC-MS-MS) method for the analysis of amphetamines in blood and urine was developed and validated. Chromatographic separation was achieved on a Nucleodur Sphinx RP column with an LC gradient (a mixture of 10 mM ammonium formate buffer and acetonitrile), ensuring the elution of amphetamine, methamphetamine, MDMA, MDA, MDEA, PMA, and ephedrine within 11 min. The method was fully validated, according to international guidelines, using only 100 and 50 microL of blood and urine, respectively. The method showed an excellent intra- and interassay precision (relative standard deviation < 11.2% and bias < 13%) for two external quality control samples (QC) for both matrices and three and two 'in house' QCs for blood and urine, respectively. Responses were linear over the investigated range (r(2) > 0.99, 2.5-400 microg/L for blood and 25-1000 microg/L for urine). Limits of quantification were determined to be 2.5 and 25 microg/L for blood and urine, respectively. Limits of detection ranged from 0.05 to 0.5 microg/L for blood and 0.25 to 2.5 microg/L for urine, depending on the compound. Furthermore, the analytes and the processed samples were demonstrated to be stable (in the autosampler for at least 72 h and after three freeze/thaw cycles), and no disturbing matrix effects were observed for all compounds. Moreover, no carryover was observed after the analysis of high concentration samples (15,000 microg/L). The method was subsequently applied to authentic blood and urine samples obtained from forensic cases, which covered a broad range of concentrations. The validation results and actual sample analyses demonstrated that this method is rugged, precise, accurate, and well-suited for routine analysis as more than 72 samples are analyzed non-stop in 24 h with minimum sample handling. The combination of the high-throughput online SPE and the well-known sensitivity and selectivity assured by MS-MS resulted in the elimination of the bottleneck associated with the sample preparation requirements and provided increased sensitivity, accuracy, and precision.

  10. Stone former urine proteome demonstrates a cationic shift in protein distribution compared to normal.

    PubMed

    Kolbach-Mandel, Ann M; Mandel, Neil S; Hoffmann, Brian R; Kleinman, Jack G; Wesson, Jeffrey A

    2017-08-01

    Many urine proteins are found in calcium oxalate stones, yet decades of research have failed to define the role of urine proteins in stone formation. This urine proteomic study compares the relative amounts of abundant urine proteins between idiopathic calcium oxalate stone forming and non-stone forming (normal) cohorts to identify differences that might correlate with disease. Random mid-morning urine samples were collected following informed consent from 25 stone formers and 14 normal individuals. Proteins were isolated from urine using ultrafiltration. Urine proteomes for each sample were characterized using label-free spectral counting mass spectrometry, so that urine protein relative abundances could be compared between the two populations. A total of 407 unique proteins were identified with the 38 predominant proteins accounting for >82% of all sample spectral counts. The most highly abundant proteins were equivalent in stone formers and normals, though significant differences were observed in a few moderate abundance proteins (immunoglobulins, transferrin, and epidermal growth factor), accounting for 13 and 10% of the spectral counts, respectively. These proteins contributed to a cationic shift in protein distribution in stone formers compared to normals (22% vs. 18%, p = 0.04). Our data showing only small differences in moderate abundance proteins suggest that no single protein controls stone formation. Observed increases in immunoglobulins and transferrin suggest increased inflammatory activity in stone formers, but cannot distinguish cause from effect in stone formation. The observed cationic shift in protein distribution would diminish protein charge stabilization, which could lead to protein aggregation and increased risk for crystal aggregation.

  11. Fast vaporization solid phase microextraction and ion mobility spectrometry: A new approach for determination of creatinine in biological fluids.

    PubMed

    Jafari, Mostafa; Ebrahimzadeh, Homeira; Banitaba, Mohamma Hossein

    2015-11-01

    In this work a rapid and simple method for creatinine determination in urine and plasma samples based on aqueous derivatization of creatinine and complete vaporization of sample (as low as 10 µL), followed by ion mobility spectrometry analysis has been proposed. The effect of four important parameters (extraction temperature, total volume of solution, desorption temperature and extraction time) on ion mobility signal has been studied. Under the optimized conditions, the quantitative response of ion mobility spectrometry for creatinine was linear in the range of 0-500 mg L(-1) with a detection limit of 0.6 mg L(-1) in urine and 0-250 mg L(-1) with a detection limit of 2.6 mg L(-1) in plasma sample. The limit of quantitation of creatinine was 2.1 mg L(-1) and 8.7 mg L(-1) in urine and plasma samples, respectively. The relative standard deviation of the method was found to be 13%. The method was successfully applied to the analysis of creatinine in biological samples, showing recoveries from 92% to 104% in urine and 101-110% in plasma samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Urine sample (image)

    MedlinePlus

    A "clean-catch" urine sample is performed by collecting the sample of urine in midstream. Men or boys should wipe clean the head ... water and rinse well. A small amount of urine should initially fall into the toilet bowl before ...

  13. Comparison of routine urinalysis and urine Gram stain for detection of bacteriuria in dogs.

    PubMed

    Way, Leilani Ireland; Sullivan, Lauren A; Johnson, Valerie; Morley, Paul S

    2013-01-01

    To determine the utility of performing urine Gram stain for detection of bacteriuria compared to routine urine sediment examination and bacterial aerobic urine culture. Prospective, observational study. University teaching hospital. Urine samples acquired via cystocentesis through convenience sampling from 103 dogs presenting to a tertiary referral institution. All samples underwent routine urinalysis, including sediment examination, as well as urine Gram stain and quantitative bacterial aerobic urine culture. The urine Gram stain demonstrated improved sensitivity (96% versus 76%), specificity (100% versus 77%), positive predictive value (100% versus 83%), and negative predictive value (93% versus 69%) when identifying bacteriuria, compared to routine urine sediment examination. The urine Gram stain is highly sensitive and specific when detecting the presence of bacteria in canine urine samples. Gram staining should be considered when bacteriuria is highly suspected and requires rapid identification while bacterial culture is pending. © Veterinary Emergency and Critical Care Society 2013.

  14. Urine human papillomavirus prevalence in women with high-grade cervical lesions.

    PubMed

    Nicolau, P; Mancebo, G; Agramunt, S; Solé-Sedeño, J M; Bellosillo, B; Muset, M M; Lloveras, B; Alameda, F; Carreras, R

    2014-12-01

    To determine the prevalence of human papillomavirus (HPV) in urine samples from women with high-grade cervical lesions. Secondary objectives are to identify the influence of socio-demographic factors and the different genotypes with urinary HPV positivity. 75 women with a positive biopsy for CIN2+ were included in the study from October 2010 to July 2011. A sample of urine was collected immediately before conization at the outpatient clinic. We analyzed the presence of HPV using a PCR technique. The mean age of the patients was 34.8 years (range 24 to 61). All patients had histological CIN2+, of whom 54.67% had CIN3. The prevalence of HPV in urine test was 58.82% in CIN2 population versus 78.05% in CIN3 patients (p 0.072). 31 different genotypes were found. The most frequent HPV genotype was 16-HPV, which was identified in 58% of women with positive HPV-DNA in urine samples. No demographic characteristics were significantly associated to urinary HPV prevalence. Most of the patients with CIN2+ showed positive results for urine HPV test. The prevalence of positive urinary HPV test was higher for patients with CIN3. HPV urine detection could be considered as an acceptable option for high-risk population who skip regular screening programs. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  15. The effectiveness of BD Vacutainer® Plus Urinalysis Preservative Tubes in preservation of urine for chemical strip analysis and particle counting

    PubMed Central

    Ekşioğlu, Merve Kaymak; Madenci, Özlem Çakır; Yücel, Nihal; Elçi, Abdullah; Turhan, Bülent; Orhan, Gani; Orçun, Asuman

    2016-01-01

    Introduction The aim of this study was to evaluate the stability of urine collected in preservative tubes for chemistry strip analyses and particle counting to determine whether the transport of urine samples with all of their constituents is possible. Materials and methods 275 pathologic urine specimens were included. Each urine sample was evaluated after 4, 8, 12, 24, and 48 hours of storage in BD Vacutainer® Plus Urinalysis Preservative (BD UAP) tubes and compared with refrigeration at 4 °C. All analyses were peformed on H-800 and FUS-200 automatic modular urine analyzers (Dirui Industry, Changchun, China). The kappa coefficients (κ), false positive (FP) and false negative (FN) rates were evaluated. κ > 0.8 was accepted as good agreement. Results Haemoglobin (Hb), leucocyte esterase (LE), and protein (Pro) analyses should be performed within 4 hours, whereas glucose (Glc) was stable until the end of 48 hours in both storage conditions. Nitrite (Nit) was well preserved in BD UAP tubes for 24 hours but was stable only up to 8 hours at 4 °C. Bilirubin (Bil) had very high FN rates even at 4 hours in both conditions. The particle counting showed high FN rates for white blood cells (WBC) and red blood cells (RBC), whereas squamous epithelial cells (EC) were stable up to 8 hours in both conditions. Conclusions Preanalytical requirements for both urine chemical strip analyses and particle counting in a unique sample were not met in either condition. Thus, the transfer of urine samples for centralization of urinalysis is not yet feasible. PMID:27346967

  16. Urine TREM-1 as a marker of urinary tract infection in children.

    PubMed

    Sierra-Diaz, Erick; Bravo Cuéllar, Alejandro; Ortiz Lazareno, Pablo Cesar; García Gutiérrez, Mariana; Georgina, Hernandez Flores; Anaya Prado, Roberto

    2017-04-01

    Objective Triggering receptor expressed on myeloid cells (TREM)-1 is a receptor that is thought to improve recognition of patients with true infection. In this study, we investigated whether Triggering receptor expressed on myeloid cells (TREM-1) is present in urine samples from children with urinary tract infection (UTI) and in samples from healthy children. Methods A total of 128 samples met the inclusion criteria for the study. Urine samples were processed for culture and urinalysis as a regular protocol for patients with UTI. Samples were classified according to culture and urinalysis results. TREM-1 protein expression was detected with flow cytometry and sTREM-1 was assessed by ELISA. Results Flow cytometry showed detectable expression of TREM-1 in 100% of samples, UTI and non-UTI groups ( p < 0.001). Mean fluorescence intensity of TREM-1 was different between the groups ( p < 0.001). Levels of sTREM-1 were detected in patients with UTI, but not in non-UTI patients. Conclusions All of our patients (healthy and diseased) showed TREM-1 expression. However, TREM-1 levels in patients with UTI tend to be higher and are associated with increased neutrophils and cytokine activity induced by bacteria.

  17. Urine TREM-1 as a marker of urinary tract infection in children

    PubMed Central

    Sierra-Diaz, Erick; Ortiz Lazareno, Pablo Cesar; García Gutiérrez, Mariana; Georgina, Hernandez Flores; Anaya Prado, Roberto

    2017-01-01

    Objective Triggering receptor expressed on myeloid cells (TREM)-1 is a receptor that is thought to improve recognition of patients with true infection. In this study, we investigated whether Triggering receptor expressed on myeloid cells (TREM-1) is present in urine samples from children with urinary tract infection (UTI) and in samples from healthy children. Methods A total of 128 samples met the inclusion criteria for the study. Urine samples were processed for culture and urinalysis as a regular protocol for patients with UTI. Samples were classified according to culture and urinalysis results. TREM-1 protein expression was detected with flow cytometry and sTREM-1 was assessed by ELISA. Results Flow cytometry showed detectable expression of TREM-1 in 100% of samples, UTI and non-UTI groups (p < 0.001). Mean fluorescence intensity of TREM-1 was different between the groups (p < 0.001). Levels of sTREM-1 were detected in patients with UTI, but not in non-UTI patients. Conclusions All of our patients (healthy and diseased) showed TREM-1 expression. However, TREM-1 levels in patients with UTI tend to be higher and are associated with increased neutrophils and cytokine activity induced by bacteria. PMID:28367708

  18. Advantage of multiple spot urine collections for estimating daily sodium excretion: comparison with two 24-h urine collections as reference.

    PubMed

    Uechi, Ken; Asakura, Keiko; Ri, Yui; Masayasu, Shizuko; Sasaki, Satoshi

    2016-02-01

    Several estimation methods for 24-h sodium excretion using spot urine sample have been reported, but accurate estimation at the individual level remains difficult. We aimed to clarify the most accurate method of estimating 24-h sodium excretion with different numbers of available spot urine samples. A total of 370 participants from throughout Japan collected multiple 24-h urine and spot urine samples independently. Participants were allocated randomly into a development and a validation dataset. Two estimation methods were established in the development dataset using the two 24-h sodium excretion samples as reference: the 'simple mean method' estimated by multiplying the sodium-creatinine ratio by predicted 24-h creatinine excretion, whereas the 'regression method' employed linear regression analysis. The accuracy of the two methods was examined by comparing the estimated means and concordance correlation coefficients (CCC) in the validation dataset. Mean sodium excretion by the simple mean method with three spot urine samples was closest to that by 24-h collection (difference: -1.62  mmol/day). CCC with the simple mean method increased with an increased number of spot urine samples at 0.20, 0.31, and 0.42 using one, two, and three samples, respectively. This method with three spot urine samples yielded higher CCC than the regression method (0.40). When only one spot urine sample was available for each study participant, CCC was higher with the regression method (0.36). The simple mean method with three spot urine samples yielded the most accurate estimates of sodium excretion. When only one spot urine sample was available, the regression method was preferable.

  19. Hair and urine testing to assess drugs of abuse consumption in couples undergoing assisted reproductive technology (ART).

    PubMed

    Pichini, Simona; De Luca, Roberto; Pellegrini, Manuela; Marchei, Emilia; Rotolo, Maria Concetta; Spoletini, Roberta; D'Aloja, Paola; Pacifici, Roberta; Mortali, Claudia; Scaravelli, Giulia

    2012-05-10

    For the first time in Europe hair and urine testing have been applied to assess drugs of abuse consumption in couples undergoing assisted reproductive technology and the eventual association of toxic habits with other lifestyle, health status and sociodemographic factors was also investigated. Couples attending five assisted reproduction centers in Rome were invited to join the study. When they presented at the Centre for the visit, they were asked to answer a structured questionnaire concerning sociodemographic characteristics and lifestyle habits, and at the same time to provide hair and urine samples. Hair and urine testing for drugs of abuse, urinary profile of principal endogenous steroids involved in fertility process (testosterone, epitestosterone, androsterone, etiocholanolone and dehydroepiandrosterone) and of alcohol and tobacco smoke biomarkers were performed with validated methodologies. Of the 594 enrolled individuals (297 couples), 352 (164 couples and 24 single individuals from the couple) completed the questionnaire and gave both hair and urine samples, apart from 3 bald men, who only gave urine samples. Urine testing showed an overall 4.8% (17 individuals) positivity to drugs of abuse: 4.2% to cannabinoids, 1.4% to cocaine and 0.85% to both drugs. Results of 4cm segment hair samples testing matched those from urine samples. Thus, taking together, results of urine and hair testing confirmed repeated use of cannabis, cocaine and both drugs in 3.7, 0.85 and 0.57% examined individuals, respectively. Drug consumers were in a statistically higher percentage active smokers and alcohol drinkers, less prone to physical activity and with a trend towards higher weight than non consumers. Finally, repeated drug consumption was associated with significant lower concentration of urinary testosterone in males and of urinary dehydroepiandrosterone in females. The findings of the present study confirm the suitability of urine testing to disclose recent drugs of abuse consumption and of hair analysis to verify repeated consumption. Association between different toxic habits and sedentary lifestyle is also substantiated by the obtained results in our cohort of couples attending assisted reproduction centers. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  20. Misclassification of iodine intake level from morning spot urine samples with high iodine excretion among Inuit and non-Inuit in Greenland.

    PubMed

    Andersen, Stig; Waagepetersen, Rasmus; Laurberg, Peter

    2015-05-14

    Iodine nutrition is commonly assessed from iodine excretion in urine. A 24 h urine sample is ideal, but it is cumbersome and inconvenient. Hence, spot urine samples with creatinine to adjust for differences in void volume are widely used. Still, the importance of ethnicity and the timing of spot urine samples need to be settled. We, thus, collected 104 early morning spot urine samples and 24 h urine samples from Inuit and non-Inuit living in Greenland. Diet was assessed by a FFQ. Demographic data were collected from the national registry and by questionnaires. Iodine was measured using the Sandell-Kolthoff reaction, creatinine using the Jaffe method and para-amino benzoic acid by the HPLC method for the estimation of completeness of urine sampling and compensation of incomplete urine samples to 24 h excretion. A population-based recruitment was done from the capital city, a major town and a settlement (n 36/48/20). Participants were seventy-eight Inuit and twenty-six non-Inuit. The median 24 h iodine excretion was 138 (25th-75th percentile 89-225) μg/97 (25th-75th percentile 72-124) μg in Inuit/non-Inuit (P= 0.030), and 153 (25th-75th percentile 97-251) μg/102 (25th-75th percentile 73-138) μg (P= 0.026) when including compensated iodine excretion. Iodine excretion in 24 h urine samples increased with a rising intake of traditional Inuit foods (P= 0.005). Iodine excretion was lower in morning spot urine samples than in 24 h urine samples (P< 0.001). This difference was associated with iodine intake levels (P< 0.001), and was statistically significant when the iodine excretion level was above 150 μg/24 h. In conclusion, the iodine intake level was underestimated from morning spot urine samples if iodine excretion was above the recommended level.

  1. Stability of cannabinoids in urine in three storage temperatures.

    PubMed

    Golding Fraga, S; Díaz-Flores Estévez, J; Díaz Romero, C

    1998-01-01

    Stability of cannabinoid compounds in urine samples were evaluated using several storage temperatures. Appreciable losses (> 22.4 percent) were observed in some urine samples, after being stored at room temperature for 10 days. Lower losses (8.1 percent) were observed when the urine samples were refrigerated for 4 weeks. The behavior of urine samples depended on the analyzed urine. This could be due to the different stability of the cannabinoids present in each urine sample. Important losses of 8.0 +/- 10.6, 15.8 +/- 4.2, and 19.6 +/- 6.7 percent were found when the urine samples were frozen during 40 days, 1 year, and 3 years, respectively. Average losses (> > 5 percent) can be observed after one day which could mainly be due to the decrease of the solubility of 11-nor-U9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) or adsorption process of cannabinoid molecules to the plastic storage containers.

  2. Substitution of human for horse urine disproves an accusation of doping*.

    PubMed

    Díaz, Silvina; Kienast, Mariana E; Villegas-Castagnasso, Egle E; Pena, Natalia L; Manganare, Marcos M; Posik, Diego; Peral-García, Pilar; Giovambattista, Guillermo

    2008-09-01

    In order to detect switching and/or manipulation of samples, the owner of a stallion asked our lab to perform a DNA test on a positive doping urine sample. The objective was to compare the urine DNA profile versus blood and hair DNA profiles from the same stallion. At first, 10 microsatellite markers were investigated to determine the horse identity. No results were obtained when horse specific markers were typed in the urine sample. In order to confirm the species origin of this sample we analyzed the mitochondrial cytochrome b gene. This analysis from blood and hair samples produced reproducible and clear PCR-RFLP patterns and DNA sequence match with those expected for horse, while the urine sample results were coincident with human. These results allowed us to exclude the urine sample from the questioned stallion and determine its human species origin, confirming the manipulation of urine sample.

  3. New Method To Estimate Total Polyphenol Excretion: Comparison of Fast Blue BB versus Folin-Ciocalteu Performance in Urine.

    PubMed

    Hinojosa-Nogueira, Daniel; Muros, Joaquín; Rufián-Henares, José A; Pastoriza, Silvia

    2017-05-24

    Polyphenols are bioactive substances of vegetal origin with a significant impact on human health. The assessment of polyphenol intake and excretion is therefore important. The Folin-Ciocalteu (F-C) method is the reference assay to measure polyphenols in foods as well as their excretion in urine. However, many substances can influence the method, making it necessary to conduct a prior cleanup using solid-phase extraction (SPE) cartridges. In this paper, we demonstrate the use of the Fast Blue BB reagent (FBBB) as a new tool to measure the excretion of polyphenols in urine. Contrary to F-C, FBBB showed no interference in urine, negating the time-consuming and costly SPE cleanup. In addition, it showed excellent linearity (r 2 = 0.9997), with a recovery of 96.4% and a precision of 1.86-2.11%. The FBBB method was validated to measure the excretion of polyphenols in spot urine samples from Spanish children, showing a good correlation between polyphenol intake and excretion.

  4. Genital region cleansing wipes: Effects on urine culture contamination.

    PubMed

    Selek, Mehmet Burak; Bektöre, Bayhan; Sezer, Ogün; Kula Atik, Tuğba; Baylan, Orhan; Özyurt, Mustafa

    2017-01-30

    Urine culture is the gold standard test for revealing the microbial agent causing urinary tract infection (UTI). Culture results are affected by sampling techniques; improper sampling leads to contamination of urine and thus contamination of the culture with urogenital flora. We aimed to evaluate the effect of urogenital cleansing, performed with chlorhexidine-containing genital region cleansing wipes (GRCW) on contamination rates. A total of 2,665 patients with UTI-related complaints and with urine culture requests from various outpatient clinics were enrolled in the study. Of the patients, 1,609 in the experimental group used GRCW before sampling, while 1,046 in the control group did not use any wipes. The contamination rate in the experimental group patients was 7.7%, while it was 15.8% in the control group. Contamination rates were significantly higher in the control group than in the experimental group for both women and men. Contamination rates for children and adults were also significantly lower in the experimental group than in the control group. Our study, conducted in a large population, showed that the use of chlorhexidine-containing cleansing wipes significantly reduced urine culture contamination rates in both genders, in both child and adult age groups. Using GRCW, collection of urine after urogenital area cleansing will decrease the contamination problem.

  5. Stability of urine specimens stored with and without preservatives at room temperature and on ice prior to urinalysis.

    PubMed

    Ercan, Müjgan; Akbulut, Emiş Deniz; Abuşoğlu, Sedat; Yılmaz, Fatma Meriç; Oğuz, Esra Fırat; Topçuoğlu, Canan; Öztekin, Volkan; Boğdaycıoğlu, Nihal

    2015-09-01

    Laboratories determine the most appropriate approach for the collection and transport of urine specimens. We investigated the effect of a chlorhexidine-based preservative tube on sample stability, compared the results of refrigerated polystyrene tubes with no additives, and investigated the effect of temperature on the performance of preservative tubes. Fresh urine specimen (n=48) aliquots in BD Vacutainer® Plus Urinalysis Preservative Tubes and polystyrene tubes were analyzed on an Iris Diagnostics iQ200. Samples in polystyrene tubes were refrigerated for 4 and 8h. Four aliquots in preservative tubes were kept at room temperature for 4, 8, 24, and 72h, while two aliquots were kept on ice for 4 and 8h. There was good agreement for all chemistry and microscopy parameters with the exceptions of white blood cells (WBCs) at 24 and 72h and red blood cells (RBCs) at 72h. Preservative tubes on ice showed a significant decrease in concordance of WBCs and calcium oxalate (CaOx) parameters compared with the results at room temperature. Results of refrigerated polystyrene tubes showed good agreement with the exceptions of WBC clumps and amorphous crystal at 8h. A chlorhexidine-containing preservative tube seems advantageous for urine sample transport from outside healthcare services. A preservative tube offers comparable results with urine samples kept in a refrigerator for 4-8h for the majority of parameters. Keeping samples at room temperature is recommended when preservative tubes are used because ice produces a negative effect on WBCs and CaOx. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  6. Amphetamine concentrations in human urine following single-dose administration of the calcium antagonist prenylamine-studies using fluorescence polarization immunoassay (FPIA) and GC-MS.

    PubMed

    Kraemer, Thomas; Roditis, Susanne K; Peters, Frank T; Maurer, Hans H

    2003-03-01

    Prenylamine (R,S-N-(3,3-diphenylpropyl-methyl-2-phenethylamine), a World Health Organization class V calcium antagonist, is known to be metabolized to amphetamine. In this study, amphetamine concentrations after a single-dose administration of prenylamine were determined to check if they reached values that could be of analytical and/or pharmacological importance in clinical and forensic toxicology. Enantiomeric composition of amphetamine was also studied. Five volunteers received a single 120-mg oral dose of prenylamine. Urine samples were analyzed using the Abbott TDx immunoassay Amphetamine/Methamphetamine II and using our routine systematic toxicological analysis (STA) gas chromatography-mass spectrometry (GC-MS) procedure. For quantitation purposes, GC-MS was used in the selected-ion monitoring (SIM) mode (ions m/z 118, 122, 240, 244) after solid-phase extraction (Isolute Confirm HCX) and derivatization (heptafluorobutyric anhydride). Amphetamine-d5 was used as internal standard (IS). Chiral separation of the heptafluorobutyrated amphetamine enantiomers was achieved using an Astec Chiraldex G-PN column. The TDx results showed a great variability for the different volunteers. A urine sample of one volunteer showed results as high as 3200 ng/mL, whereas the urine samples of another volunteer never gave results greater than the TDx detection limit (100 ng/mL). Using the STA procedure, the presence of amphetamine could be confirmed in all urine samples with TDx results greater than the cutoff value (300 ng/mL). Using the GC-MS SIM method, amphetamine concentrations up to 1280 ng/mL were determined. Chiral analysis revealed that both enantiomers of amphetamine were present in the samples with a surplus of the S(+)-enantiomer in the early phase of excretion. Forensic implications are discussed.

  7. Unmetabolized VOCs in urine as biomarkers of low level occupational exposure.

    PubMed

    Janasik, Beata; Jakubowski, Marek; Wesołowski, Wiktor; Kucharska, Małgorzata

    2010-01-01

    To compare the usefulness of determining unchanged forms of volatile organic compounds (VOCs), namely toluene (TOL), ethylbenzene (EB) and xylene (XYL), in urine with the effectiveness of the already used biomarkers of occupational exposure. Surveys were conducted in two workplaces (paint factory and footwear factory). In total, 65 subjects participated in the study. Air samples were collected using individual samplers during work shift. Urine and blood samples were collected at the end of work shift. Urine samples were analyzed for unchanged compounds and selected metabolites, while blood samples were tested for unchanged compounds. VOCs in blood and urine were determined by solid phase microextraction gas chromatography (SPME-GC-MS). In the paint factory, the geometric mean (GM) concentrations of VOCs in the air ranged as follows: 0.2-4.7 mg/m(3) for TOL, 0.4-40.9 mg/m(3) for EB and 0.1-122.6 mg/m(3) for XYL. In the footwear factory, the GM concentration of TOL in the air amounted to 105.4 mg/m(3). A significant correlation (p < 0.05) was observed between VOCs in blood, urine and air. The regression analyses performed for paint factory workers showed that TOL-U and TOL-B were better biomarkers of exposure (r = 0.72 and r = 0.81) than benzoic acid (r = 0.12) or o-cresol (r = 0.55). The findings of the study point out that the concentration of unchanged VOCs in urine can be a reliable biological indicator of low level occupational exposure to these compounds.

  8. Effectiveness of a Communication for Behavioral Impact (COMBI) Intervention to Reduce Salt Intake in a Vietnamese Province Based on Estimations From Spot Urine Samples.

    PubMed

    Do, Ha Thi Phuong; Santos, Joseph Alvin; Trieu, Kathy; Petersen, Kristina; Le, Mai Bach; Lai, Duc Truong; Bauman, Adrian; Webster, Jacqui

    2016-11-01

    This study evaluated the effectiveness of the Communication for Behavioral Impact (COMBI)-Eat Less Salt intervention conducted in Viet Tri, Vietnam. The behavior change intervention was implemented in four wards and four communes for one year, which included mass media communication, school interventions, community programs, and focus on high-risk groups. Mean sodium excretion was estimated from spot urine samples using different equations. A subsample provided 24-hour urine to validate estimates from spot urine. Information about salt-related knowledge and behaviors was also collected. There were 513 participants at both baseline and follow-up. Mean sodium excretion estimated from spot urines fell significantly from 8.48 g/d at baseline to 8.05 g/d at follow-up (P=.001). All spot equations demonstrated a significant reduction in sodium levels; however, the change was smaller than the measured 24-hour urine. Participants showed improved knowledge and behaviors following the intervention. The COMBI intervention was effective in lowering average population salt intake and improving knowledge and behaviors. ©2016 Wiley Periodicals, Inc.

  9. Solid-phase microextraction of methadone in urine samples by electrochemically co-deposited sol-gel/Cu nanocomposite fiber.

    PubMed

    Mohammadiazar, Sirwan; Hasanli, Fateme; Maham, Mehdi; Payami Samarin, Somayeh

    2017-08-01

    Electrochemically co-deposited sol-gel/Cu nanocomposites have been introduced as a novel, simple and single-step technique for preparation of solid-phase microextraction (SPME) coating to extract methadone (MDN) (a synthetic opioid) in urine samples. The porous surface structure of the sol-gel/Cu nanocomposite coating was revealed by scanning electron microscopy. Direct immersion SPME followed by HPLC-UV determination was employed. The factors influencing the SPME procedure, such as the salt content, desorption solvent type, pH and equilibration time, were optimized. The best conditions were obtained with no salt content, acetonitrile as desorption solvent type, pH 9 and 10 min equilibration time. The calibration graphs for urine samples showed good linearity. The detection limit was about 0.2 ng mL -1 . Also, the novel method for preparation of nanocomposite fiber was compared with previously reported techniques for MDN determination. The results show that the novel nanocomposite fiber has relatively high extraction efficiency. Copyright © 2016 John Wiley & Sons, Ltd.

  10. Fast screening tests for the simultaneous detection of 11 drugs of abuse in urine specimens. A forensic epidemiology study of 28,298 cases in Tunisia.

    PubMed

    Moslah, B; Araoud, M; Nouioui, M A; Najjar, S; Amira, D; Ben Salah, N; Hedhili, A

    2018-02-01

    Forensic investigation performed on people suspected to be drug abusers covering all Tunisian cities was conducted by monitoring an epidemiological study of human urine samples surveying positive rates of consumption for drugs of abuse. The forensic investigations were conducted on a total of 28,298 arrested individuals suspected to be drug addicts during five years (January 2010-December 2015). An immunoassay screening tests to detect elevated levels of drugs classes in urine samples was performed. These screening assays provide a preliminary qualitative test result. Only positives urine specimens were analyzed with GC-MS for confirmation. Except for cannabis, the results showed insignificant number of positive cases for cocaine, ecstasy (MDMA) and amphetamine consumptions (<1%). Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Reproducibility of NMR Analysis of Urine Samples: Impact of Sample Preparation, Storage Conditions, and Animal Health Status

    PubMed Central

    Schreier, Christina; Kremer, Werner; Huber, Fritz; Neumann, Sindy; Pagel, Philipp; Lienemann, Kai; Pestel, Sabine

    2013-01-01

    Introduction. Spectroscopic analysis of urine samples from laboratory animals can be used to predict the efficacy and side effects of drugs. This employs methods combining 1H NMR spectroscopy with quantification of biomarkers or with multivariate data analysis. The most critical steps in data evaluation are analytical reproducibility of NMR data (collection, storage, and processing) and the health status of the animals, which may influence urine pH and osmolarity. Methods. We treated rats with a solvent, a diuretic, or a nephrotoxicant and collected urine samples. Samples were titrated to pH 3 to 9, or salt concentrations increased up to 20-fold. The effects of storage conditions and freeze-thaw cycles were monitored. Selected metabolites and multivariate data analysis were evaluated after 1H NMR spectroscopy. Results. We showed that variation of pH from 3 to 9 and increases in osmolarity up to 6-fold had no effect on the quantification of the metabolites or on multivariate data analysis. Storage led to changes after 14 days at 4°C or after 12 months at −20°C, independent of sample composition. Multiple freeze-thaw cycles did not affect data analysis. Conclusion. Reproducibility of NMR measurements is not dependent on sample composition under physiological or pathological conditions. PMID:23865070

  12. Reproducibility of NMR analysis of urine samples: impact of sample preparation, storage conditions, and animal health status.

    PubMed

    Schreier, Christina; Kremer, Werner; Huber, Fritz; Neumann, Sindy; Pagel, Philipp; Lienemann, Kai; Pestel, Sabine

    2013-01-01

    Spectroscopic analysis of urine samples from laboratory animals can be used to predict the efficacy and side effects of drugs. This employs methods combining (1)H NMR spectroscopy with quantification of biomarkers or with multivariate data analysis. The most critical steps in data evaluation are analytical reproducibility of NMR data (collection, storage, and processing) and the health status of the animals, which may influence urine pH and osmolarity. We treated rats with a solvent, a diuretic, or a nephrotoxicant and collected urine samples. Samples were titrated to pH 3 to 9, or salt concentrations increased up to 20-fold. The effects of storage conditions and freeze-thaw cycles were monitored. Selected metabolites and multivariate data analysis were evaluated after (1)H NMR spectroscopy. We showed that variation of pH from 3 to 9 and increases in osmolarity up to 6-fold had no effect on the quantification of the metabolites or on multivariate data analysis. Storage led to changes after 14 days at 4°C or after 12 months at -20°C, independent of sample composition. Multiple freeze-thaw cycles did not affect data analysis. Reproducibility of NMR measurements is not dependent on sample composition under physiological or pathological conditions.

  13. Diagnostic value of JC/BK virus antibody immunohistochemistry staining in urine samples from posttransplant immunosuppressed patients in relation to polyomavirus reactivation.

    PubMed

    Yuste, Rosario Sanchez; Frías, Carolina; López, Ana; Vallejo, Carlos; Martín, Paloma; Bellas, Carmen

    2008-01-01

    To compare the diagnostic value of cytology and immunohistochemistry staining (IHS) of urine samples for polyomavirus reactivation diagnosis. Sixty-eight urine samples collected from 18 immunosuppressed patients were analyzed by Papanicolaou and IHS with a JC/BK virus-specific monoclonal antibody. Overall, polyomavirus BK (BKV) was positive in 11 of 18 patients (61.1%) (3 of whom developed hemorrhagic cystitis) and in 23 of 68 urine samples (28%). Of 23 samples, 4 (17%) were positive by 1 of the 2 techniques, only. Of 23 samples, 19 (83%) were positive by both methods. In matching urine samples from the same patient, the number of BKV-infected positive cells detected by IHS in urine slides was higher than those detected by Papanicolaou staining (71.3%). The main advantage of LHS is that it allowed confirmation of BKV infection diagnosis in urine samples. IHS detected more BKV-infected cells in samples with few positive urothelial cells, which would have gone undetected if only Papanicolaou staining had been used as the BKV screening method. Urine samples testing for BKV by both techniques will improve diagnosis in asymptomatic patients, allowing early therapeutic intervention and a better clinical outcome.

  14. Collection fluid helps preservation in voided urine cytology.

    PubMed

    Raistrick, J; Shambayati, B; Dunsmuir, W

    2008-04-01

    Degenerative change caused by delay in processing contributes to false-negative and false-positive diagnosis of urothelial carcinoma in cytology. The aim of the study was to see if the use of a collection fluid for urine samples made a significant difference to urine cytology diagnosis, and if one was better suited for routine use in the hospital laboratory. Three cell collection fluids were evaluated by analysing the preservation and degeneration of cells in urine samples, as was the routine preparation which did not use a collection fluid. In the design study 50 voided urine specimens were taken at random from the hospital haematuria clinic. Three commercially available collection fluids cytolyt, cytospin and cytoRich Blue and the hospital's routine conventional preparation of urine were compared. The degree of degeneration, and so preservation, was assessed by a table of chosen criteria; then ranked and analysed by Friedman's nonparametric test, at P = 0.05. A second table showing the cell content of each slide was also made. These showed no significant diagnostic difference between the collection fluids, but there was a significant difference between the collection fluids and the routine preparation. Minor differences that do not affect diagnosis, such as crystals and ghost red blood cells, were noted in cytospin and cytoRich Blue. It is recommended that a collection fluid is used. This choice should be made after health and safety issues and cost are considered.

  15. Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection

    PubMed Central

    Ruman, Marek; Narkowicz, Sylwia; Namieśnik, Jacek

    2017-01-01

    A simple and accurate ion chromatography (IC) method with pulsed amperometric detection (PAD) was proposed for the determination of cyanide ion in urine, sweat, and saliva samples. The sample pretreatment relies on alkaline digestion and application of Dionex OnGuard II H cartridge. Under the optimized conditions, the method showed good linearity in the range of 1–100 μg/L for urine, 5–100 μg/L for saliva, and 3–100 μg/L for sweat samples with determination coefficients (R) > 0.992. Low detection limits (LODs) in the range of 1.8 μg/L, 5.1 μg/L, and 5.8 μg/L for urine, saliva, and sweat samples, respectively, and good repeatability (CV < 3%, n = 3) were obtained. The proposed method has been successfully applied to the analysis of human biological samples. PMID:29348966

  16. Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection.

    PubMed

    Jaszczak, Ewa; Ruman, Marek; Narkowicz, Sylwia; Namieśnik, Jacek; Polkowska, Żaneta

    2017-01-01

    A simple and accurate ion chromatography (IC) method with pulsed amperometric detection (PAD) was proposed for the determination of cyanide ion in urine, sweat, and saliva samples. The sample pretreatment relies on alkaline digestion and application of Dionex OnGuard II H cartridge. Under the optimized conditions, the method showed good linearity in the range of 1-100  μ g/L for urine, 5-100  μ g/L for saliva, and 3-100  μ g/L for sweat samples with determination coefficients ( R ) > 0.992. Low detection limits (LODs) in the range of 1.8  μ g/L, 5.1  μ g/L, and 5.8  μ g/L for urine, saliva, and sweat samples, respectively, and good repeatability (CV < 3%, n = 3) were obtained. The proposed method has been successfully applied to the analysis of human biological samples.

  17. Temporal variability of pyrethroid metabolite levels in bedtime, morning, and 24-h urine samples for 50 adults in North Carolina.

    PubMed

    Morgan, Marsha K; Sobus, Jon R; Barr, Dana Boyd; Croghan, Carry W; Chen, Fu-Lin; Walker, Richard; Alston, Lillian; Andersen, Erik; Clifton, Matthew S

    2016-01-01

    Pyrethroid insecticides are widely used to control insects in both agricultural and residential settings worldwide. Few data are available on the temporal variability of pyrethroid metabolites in the urine of non-occupationally exposed adults. In this work, we describe the study design and sampling methodology for the Pilot Study to Estimate Human Exposures to Pyrethroids using an Exposure Reconstruction Approach (Ex-R study). Two major objectives were to quantify the concentrations of several pyrethroid metabolites in bedtime, first morning void (FMV), and 24-h urine samples as concentration (wet weight), specific-gravity (SG) corrected, creatinine (CR) corrected, and excretion rate values for 50 Ex-R adults over a six-week monitoring period and to determine if these correction approaches for urine dilution reduced the variability of the biomarker levels. The Ex-R study was conducted at the United States Environmental Protection Agency's Human Studies Facility in Chapel Hill, North Carolina USA and at participants' homes within a 40-mile radius of this facility. Recruitment of participants and field activities occurred between October 2009 and May 2011. Participants, ages 19-50 years old, provided daily food, activity, and pesticide-use diaries and collected their own urine samples (bedtime, FMV, and 24-h) during weeks 1, 2, and 6 of a six-week monitoring period. A total of 2503 urine samples were collected from the study participants. These samples were analyzed for the pyrethroid metabolites 3-phenoxybenzoic acid (3-PBA), cis/trans-3-(2,2-dichlorovinyl)-2,2-dimethyl-cyclopropane carboxylic acid (cis/trans-DCCA), and 2-methyl-3-phenylbenzoic acid (MPA) using high performance liquid chromatography/tandem mass spectrometry. Only 3-PBA was frequently detected (>50%) in the adult urine samples. Median urinary 3-PBA levels were 0.88 ng/mL, 0.96 ng/mL-SG, 1.04 ng/mg, and 1.04 ng/min for concentration, SG-corrected, CR-corrected, and excretion rate values, respectively, across all urine samples. The results showed that median urinary 3-PBA concentrations were consistently the lowest in FMV samples (0.77 ng/mL, 0.68 ng/mL-SG, 0.68 ng/mg, and 0.58 ng/min) and the highest in 24-h samples (0.92 ng/mL, 1.06 ng/mL-SG, 1.18 ng/mg, and 1.19 ng/min) across all four methods. Intraclass correlation coefficient (ICC) estimates for 3-PBA indicated poor reproducibility (<0.22) for all urine sample types and methods over a day, week, and six weeks. Correcting for urine sample dilution, based on either SG, CR or urine output, introduced additional measurement variability both between- and within-individuals. These results indicate that a single measure of urinary 3-PBA was not sufficient to characterize average exposure regardless of sample type, correction method, and time frame of collection. In addition, the study results can be used to inform the design of exposure characterization strategies in relevant environmental epidemiology studies in the future. Published by Elsevier Inc.

  18. Validation of a multi-analyte HPLC-DAD method for determination of uric acid, creatinine, homovanillic acid, niacinamide, hippuric acid, indole-3-acetic acid and 2-methylhippuric acid in human urine.

    PubMed

    Remane, Daniela; Grunwald, Soeren; Hoeke, Henrike; Mueller, Andrea; Roeder, Stefan; von Bergen, Martin; Wissenbach, Dirk K

    2015-08-15

    During the last decades exposure sciences and epidemiological studies attracts more attention to unravel the mechanisms for the development of chronic diseases. According to this an existing HPLC-DAD method for determination of creatinine in urine samples was expended for seven analytes and validated. Creatinine, uric acid, homovanillic acid, niacinamide, hippuric acid, indole-3-acetic acid, and 2-methylhippuric acid were separated by gradient elution (formate buffer/methanol) using an Eclipse Plus C18 Rapid Resolution column (4.6mm×100mm). No interfering signals were detected in mobile phase. After injection of blank urine samples signals for the endogenous compounds but no interferences were detected. All analytes were linear in the selected calibration range and a non weighted calibration model was chosen. Bias, intra-day and inter-day precision for all analytes were below 20% for quality control (QC) low and below 10% for QC medium and high. The limits of quantification in mobile phase were in line with reported reference values but had to be adjusted in urine for homovanillic acid (45mg/L), niacinamide 58.5(mg/L), and indole-3-acetic acid (63mg/L). Comparison of creatinine data obtained by the existing method with those of the developed method showing differences from -120mg/L to +110mg/L with a mean of differences of 29.0mg/L for 50 authentic urine samples. Analyzing 50 authentic urine samples, uric acid, creatinine, hippuric acid, and 2-methylhippuric acid were detected in (nearly) all samples. However, homovanillic acid was detected in 40%, niacinamide in 4% and indole-3-acetic acid was never detected within the selected samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Volatile organic compounds as biomarkers of bladder cancer: Sensitivity and specificity using trained sniffer dogs.

    PubMed

    Willis, Carolyn M; Britton, Lezlie E; Harris, Rob; Wallace, Joshua; Guest, Claire M

    In a previous canine study, we demonstrated that volatile organic compounds specific to bladder cancer are present in urine headspace, subsequently showing that up to 70% of tumours can be correctly classified using an electronic nose. This study aimed to evaluate the sensitivity and specificity which can be achieved by a group of four trained dogs. In a series of 30 double-blind test runs, each consisting of one bladder cancer urine sample placed alongside six controls, the highest sensitivity achieved by the best performing dog was 73% (95% CI 55-86%), with the group as a whole correctly identifying the cancer samples 64% (95% CI 55-73%) of the time. Specificity of the dogs individually ranged from 92% (95% CI 82-97%) for urine samples obtained from healthy, young volunteers down to 56% (95% CI 42-68%) for those taken from older patients with non-cancerous urological disease. Odds ratio comparisons confirmed a significant decrease in performance as the extent of urine dipstick abnormality and/or pathology amongst the control population increased. Importantly, however, statistical analysis indicated that covariates such as smoking, gender and age, as well as blood, protein and /or leucocytes in the urine did not significantly alter the odds of response to the cancer samples. Our results provide further evidence that volatile biomarkers for bladder cancer exist in urine headspace, and that these have the potential to be exploited for diagnosis.

  20. Spectrophotometric photodynamic detection involving extracorporeal treatment with hexaminolevulinate for bladder cancer cells in voided urine.

    PubMed

    Nakai, Yasushi; Ozawa, Toshiyuki; Mizuno, Fumiko; Onishi, Sayuri; Owari, Takuya; Hori, Syunta; Morizawa, Yosuke; Tatsumi, Yosihiro; Miyake, Makito; Tanaka, Nobumichi; Tsuruta, Daisuke; Fujimoto, Kiyohide

    2017-11-01

    To evaluate the feasibility of hexaminolevulinate (HAL) for the photodynamic detection of cancer cells in voided urine. This study included 50 patients with bladder cancer that was confirmed histologically after transurethral resection (bladder cancer group) and 50 outpatients without a history of urothelial carcinoma or cancer-related findings (no malignancy group). One third of the voided urine samples were incubated with aminolevulinic acid (ALA-treated samples), one third were incubated with HAL (HAL-treated samples), and the remaining samples were incubated without treatment (untreated samples). For detecting cellular protoporphyrin IX levels, the intensity of the samples at the excitation wavelength of 405 nm was measured using a spectrophotometer. The difference between the intensity of the ALA-treated or HAL-treated samples and the untreated samples at 635 nm was calculated. HAL-induced fluorescence cytology (HFC) showed that the difference was significantly higher in patients with high-grade tumors than in those with low-grade tumors (p = 0.0003) and the difference was significantly higher in patients with low-grade tumors than in those without a history of urothelial carcinoma or cancer-related findings (p = 0.021). The areas under the receiver operating characteristic curves of ALA-induced fluorescence cytology (AFC) and HFC were 0.77 and 0.81, respectively. The AUC of HFC was significantly higher than that of AFC (p < 0.0001). The overall sensitivity values for conventional cytology, AFC, and HFC were 49, 74, and 74%, respectively. The overall specificity values for AFC and HFC were 70 and 94%, respectively. Spectrophotometric photodynamic detection involving extracorporeal treatment with HAL for bladder cancer cells in voided urine showed high accuracy. This bladder cancer detection method is easy and cost-effective, and has the potential for clinical use.

  1. Antibiotic Screening of Urine Culture for Internal Quality Audit at Amrita Hospital, Kochi.

    PubMed

    Suresh, Aswathy; Gopinathan, Anusha; Dinesh, Kavitha R; Kumar, Anil

    2017-07-01

    Urine antimicrobial activity is a seldom analysed laboratory test which greatly impacts the quantification of urine specimens. Presence of antimicrobial activity in the urine reduces the bacterial load in these specimens. Hence, the chances of erroneously reporting insignificant bacteriuria can be reduced on analysis of the antimicrobial activity in urine. The aim of the study was to measure the antimicrobial activity of urine samples obtained from patients in a tertiary care hospital. A total of 100 urine specimens were collected from the study group. Tests like wet mount, Gram staining and culture were performed. Antimicrobial susceptibility testing was done on the bacteria isolated from each specimen. The urine specimens were reported as significant bacteriuria (>105 Colony Forming Unit (CFU)/ml) and insignificant bacteriuria (<105 CFU/ml - clean catch midstream urine; <102 CFU/ml - catheterized urine sample) according to the CFU/ml. Staphylococcus aureus ATCC ® 25923 ™ and Escherichia coli ATCC ® 25922 ™ were used to identify the presence of antimicrobial activity in the urine sample by Urine Anti-Bacterial substance Assay (UABA). McNemar test was used for statistical analysis using Statistical Package for the Social Sciences (SPSS) version 21.0. On analysis of the antimicrobial activity of urine sample with the prior antibiotic history of the patients, 17 were true positives and 43 were true negatives. Twenty six of samples with UABA positivity were culture negative and 28 samples with UABA positivity were culture positive. Sensitivity and specificity of the test was 85% and 53.8% respectively. Accuracy of the test was 60%. The p-value of UABA was <0.001. Enterobacteriaceae was the most common bacterial family isolated from the urine specimens. A total of 85% patients responded to treatment. Presence of antimicrobial activity in urine has a great impact on the interpretation of urine culture reports. Identification of urine antimicrobial activity helps in evaluating the quantification of bacterial growth reported in urine culture. It facilitates speedy recovery of patients by early administration of antibiotics.

  2. Hydration status in adolescent runners: pre and post training

    NASA Astrophysics Data System (ADS)

    Ashadi, K.; Mirza, D. N.; Siantoro, G.

    2018-01-01

    The adequacy of body fluids is important for athletes in supporting performance. The purpose of this research was to determine the hydration status of athletes before and after training. The study was a qualitative descriptive by using random sampling. All athletes were trained for approximately 60 minutes. And they were asked to analyze their body fluid pattern routinely. Data were obtained through urine color measurement. The urinary was taken at pre and post training and was immediately assessed in the afternoon. Based on pre-training urine samples, a mean of urine color scale was 3.1 point. It meant that only 31.2% of the athletes were in dehydrated condition. However, after exercising, urine color index showed scale 4.1. And 62.5% of the athletes experienced dehydration. The results showed that there was a significant change in hydration level before and after training. It can be concluded that training for a long time increases the risk of dehydration. It is important for athletes to meet the needs of body fluids in order to avoid functional impairment in the body during sports activities.

  3. Mean population salt intake estimated from 24-h urine samples and spot urine samples: a systematic review and meta-analysis.

    PubMed

    Huang, Liping; Crino, Michelle; Wu, Jason H Y; Woodward, Mark; Barzi, Federica; Land, Mary-Anne; McLean, Rachael; Webster, Jacqui; Enkhtungalag, Batsaikhan; Neal, Bruce

    2016-02-01

    Estimating equations based on spot urine samples have been identified as a possible alternative approach to 24-h urine collections for determining mean population salt intake. This review compares estimates of mean population salt intake based upon spot and 24-h urine samples. We systematically searched for all studies that reported estimates of daily salt intake based upon both spot and 24-h urine samples for the same population. The associations between the two were quantified and compared overall and in subsets of studies. A total of 538 records were identified, 108 were assessed as full text and 29 were included. The included studies involved 10,414 participants from 34 countries and made 71 comparisons available for the primary analysis. Overall average population salt intake estimated from 24-h urine samples was 9.3 g/day compared with 9.0 g/day estimated from the spot urine samples. Estimates based upon spot urine samples had excellent sensitivity (97%) and specificity (100%) at classifying mean population salt intake as above or below the World Health Organization maximum target of 5 g/day. Compared with the 24-h samples, estimates based upon spot urine overestimated intake at lower levels of consumption and underestimated intake at higher levels of consumption. Estimates of mean population salt intake based upon spot urine samples can provide countries with a good indication of mean population salt intake and whether action on salt consumption is required. Published by Oxford University Press on behalf of the International Epidemiological Association 2015. This work is written by US Government employees and is in the public domain in the US.

  4. Endogenous nandrolone metabolites in human urine. Two-year monitoring of male professional soccer players.

    PubMed

    Le, Bizec Bruno; Bryand, Fabrice; Gaudin, Isabelle; Monteau, Fabrice; Poulain, Frédéric; Andre, François

    2002-01-01

    19-Norandrosterone (19-NA) and 19-noretiocholanolone (19-NE) are the two main indicators used to prove the illegal use of nandrolone by humans. Recent studies showed that 19-NA and 19-NE can be endogenously produced in some individuals. The mediated cases observed over the last three years generated some questions about the appropriateness of the official International Olympic Committee cutoff level, which is 2 ng/mL of 19-NA in male urine samples. In the present study, professional soccer players belonging to the French First League were studied over a period of 19 months. In total, 385 urine samples were taken immediately before and after soccer competitions and were coupled with 200 blood samples for testosterone and LH determination. Results of the study showed that the mean values for 19-NA and 19-NE were 0.097 ng/mL and 0.033 ng/mL, respectively. For 19-NA, 70% of the samples proved to be below 0.1 ng/mL, whereas less than 20% were found to be between 0.1 and 0.2 ng/mL, and 7% were between 0.2 and 0.3 ng/mL. Only four urine samples were above 1.0 ng/mL; the maximal value was 1.79 ng/mL. For 19-NE, only one sample was above 1.0 ng/mL; the value was 1.42 ng/mL. Concentrations of these compounds after games were generally significantly higher than those before games.

  5. Trends in Occupational Exposure to Styrene in the European Glass Fibre-Reinforced Plastics Industry

    PubMed Central

    Van Rooij, J. G. M.; Kasper, A.; Triebig, G.; Werner, P.; Kromhout, H.

    2008-01-01

    Aim: This study presents temporal trends of styrene exposure for workers in the European glass fibre-reinforced plastics (GRP) industry during the period 1966–2002. Methods: Data of personal styrene exposure measurements were retrieved from reports, databases and peer-reviewed papers. Only sources with descriptive statistics of personal measurements were accepted. The styrene exposure data cover personal air samples and biological monitoring data, that is, urinary styrene metabolites (mandelic acid and/or phenylglyoxylic acid) and styrene in blood. Means of series of measurements were categorized by year, country, production process, job and sampling strategy. Linear mixed models were used to identify temporal trends and factors affecting exposure levels. Results: Personal exposure measurements were available from 60 reports providing data on 24145 1–8-h time-weighted average shift personal air samples. Available data of biological exposure indicators included measurements of mandelic acid in post-shift urine (6361 urine samples being analysed). Trend analyses of the available styrene exposure data showed that the average styrene concentration in the breathing zone of open-mould workers in the European GRP industry has decreased on average by 5.3% per year during the period 1966–1990 and by only 0.4% annually in the period after 1990. The highest exposures were measured in Southern Europe and the lowest exposures in Northern Europe with Central Europe in between. Biological indicators of styrene (mandelic acid in post-shift urine) showed a somewhat steeper decline (8.9%), most likely because urine samples were collected in companies that showed a stronger decrease of styrene exposure in air than GRP companies where no biological measurements were carried out. PMID:18550625

  6. Diagnostic performance of random urine samples using albumin concentration vs ratio of albumin to creatinine for microalbuminuria screening in patients with diabetes mellitus: a systematic review and meta-analysis.

    PubMed

    Wu, Hon-Yen; Peng, Yu-Sen; Chiang, Chih-Kang; Huang, Jenq-Wen; Hung, Kuan-Yu; Wu, Kwan-Dun; Tu, Yu-Kang; Chien, Kuo-Liong

    2014-07-01

    A random urine sample measuring the albumin concentration (UAC) without simultaneously measuring the urinary creatinine is less expensive than measuring the ratio of albumin to creatinine (ACR), but comparisons of their diagnostic performance for microalbuminuria screening among patients with diabetes mellitus (DM) have not been undertaken in previous meta-analyses. To compare the diagnostic performance of the UAC vs the ACR in random urine samples for microalbuminuria screening among patients with DM. Electronic literature searches of PubMed, MEDLINE, and Scopus for English-language publications from the earliest available date of indexing through July 31, 2012. Clinical studies assessing the UAC or the ACR of random urine samples in detecting the presence of microalbuminuria among patients with DM using a urinary albumin excretion rate of 30 to 300 mg/d in 24-hour timed urine collections as the criterion standard. Bivariate random-effects models for analysis and pooling of the diagnostic performance measures across studies, as well as comparisons between different screening tests. The primary end point was the diagnostic performance measures of the UAC or the ACR in random urine samples, as well as comparisons between them. We identified 14 studies, with a total of 2078 patients; 9 studies reported on the UAC, and 12 studies reported on the ACR. Meta-analysis showed pooled sensitivities of 0.85 and 0.87 for the UAC and the ACR, respectively, and pooled specificities of 0.88 and 0.88, respectively. No differences in sensitivity (P = .70), specificity (P = .63), or diagnostic odds ratios (P = .59) between the UAC and the ACR were found. The time point of urine collection did not affect the diagnostic performance of either test. The UAC and the ACR yielded high sensitivity and specificity for the detection of microalbuminuria. Because the diagnostic performance of the UAC is comparable to that of the ACR, our findings indicate that the UAC of random urine samples may become the screening tool of choice for the population with DM, considering the rising incidence of DM and the constrained health care resources in many countries.

  7. Development of isotope labeling liquid chromatography mass spectrometry for mouse urine metabolomics: quantitative metabolomic study of transgenic mice related to Alzheimer's disease.

    PubMed

    Peng, Jun; Guo, Kevin; Xia, Jianguo; Zhou, Jianjun; Yang, Jing; Westaway, David; Wishart, David S; Li, Liang

    2014-10-03

    Because of a limited volume of urine that can be collected from a mouse, it is very difficult to apply the common strategy of using multiple analytical techniques to analyze the metabolites to increase the metabolome coverage for mouse urine metabolomics. We report an enabling method based on differential isotope labeling liquid chromatography mass spectrometry (LC-MS) for relative quantification of over 950 putative metabolites using 20 μL of urine as the starting material. The workflow involves aliquoting 10 μL of an individual urine sample for ¹²C-dansylation labeling that target amines and phenols. Another 10 μL of aliquot was taken from each sample to generate a pooled sample that was subjected to ¹³C-dansylation labeling. The ¹²C-labeled individual sample was mixed with an equal volume of the ¹³C-labeled pooled sample. The mixture was then analyzed by LC-MS to generate information on metabolite concentration differences among different individual samples. The interday repeatability for the LC-MS runs was assessed, and the median relative standard deviation over 4 days was 5.0%. This workflow was then applied to a metabolomic biomarker discovery study using urine samples obtained from the TgCRND8 mouse model of early onset familial Alzheimer's disease (FAD) throughout the course of their pathological deposition of beta amyloid (Aβ). It was showed that there was a distinct metabolomic separation between the AD prone mice and the wild type (control) group. As early as 15-17 weeks of age (presymptomatic), metabolomic differences were observed between the two groups, and after the age of 25 weeks the metabolomic alterations became more pronounced. The metabolomic changes at different ages corroborated well with the phenotype changes in this transgenic mice model. Several useful candidate biomarkers including methionine, desaminotyrosine, taurine, N1-acetylspermidine, and 5-hydroxyindoleacetic acid were identified. Some of them were found in previous metabolomics studies in human cerebrospinal fluid or blood samples. This work illustrates the utility of this isotope labeling LC-MS method for biomarker discovery using mouse urine metabolomics.

  8. Monitoring of occupational exposure to methylene chloride: sampling protocol and stability of urine samples.

    PubMed

    Hoffer, Erica; Tabak, Arek; Shcherb, Inna; Wiener, Avi; Bentur, Yedidia

    2005-01-01

    A sampling protocol for biomonitoring of the volatile solvent methylene chloride (MeCl(2)) by analysis of urine from exposed workers was established. Storage temperature, sample volume in headspace vial (HSV), and time to sealing HSV on determination of MeCl(2) in urine were evaluated. MeCl(2) was analyzed by a solid-phase microextraction technique combined with gas chromatography. Volume of urine in HSV has no effect on MeCl(2) analysis. Delays of 30 and 60 min from collection of urine until sealing the HSV caused 14.47 +/- 6.98% and 26.17 +/- 9.57% decreases from baseline concentration, respectively. MeCl(2) concentration in spiked urine samples stored in sealed HSVs decreased on day 2 and then remained stable for 2 weeks. Refrigeration did not improve recovery although it seems to be associated with less variability. MeCl(2) in urine samples of seven exposed workers was in the range of 0.02-0.06 mg/L. Sampling of MeCl(2)-containing urine should include collection of urine in closed plastic bottles, transfer to HSV within 15 min, sealing and clamping of HSV within 15 s, and storage of HSV in refrigeration until analysis, but no longer than 2 weeks. Standard samples should be prepared on the day of test sample collection and handled under the same conditions.

  9. Evaluation of the performance of Human Papillomavirus testing in paired urine and clinician-collected cervical samples among women aged over 30 years in Bhutan.

    PubMed

    Tshomo, Ugyen; Franceschi, Silvia; Tshokey, Tshokey; Tobgay, Tashi; Baussano, Iacopo; Tenet, Vanessa; Snijders, Peter J F; Gheit, Tarik; Tommasino, Massimo; Vorsters, Alex; Clifford, Gary M

    2017-04-08

    Urine sampling may offer a less invasive solution than cervical sampling to test for human papillomavirus (HPV) for HPV vaccine impact monitoring. Paired samples of urine and exfoliated cervical cells were obtained for 89 women with history of high-risk (HR) HPV-positive normal cytology in Bhutan. Urine sampling protocol included self-collection of first-void urine immediately into a conservation medium and procedures to optimize DNA yield. Colposcopical abnormalities were biopsied. Two HPV assays were used: a multiplex type-specific PCR (E7-MPG) and a less analytically sensitive GP5+/6+ PCR followed by reverse line blot. HPV positivity for 21 types common to both assays was similar in urine and cells by E7-MPG (62.9% and 57.3%, respectively, p = 0.32) but lower in urine by GP5+/6+ (30.3% and 40.4%, p = 0.05). HPV6/11/16/18 positivity did not significantly differ between urine and cells by either assay. Sensitivity of urine (using cells as gold standard) to detect 21 HPV types was 80% and 58% for E7-MPG and GP5+/6+, respectively, with specificity 61% and 89%. HPV type distribution in urine and cells was similar, regardless of assay. The 5 detected CIN3+ were HR-HPV positive in cells by both assays, compared to 4 and 3 by E7-MPG and GP5+/6+, respectively, in urine samples. For the monitoring of vaccine impact, we demonstrate validity of a urine sampling protocol to obtain HPV prevalence data that are broadly comparable to that from cervical cells. However, detection of HPV in urine varies according to assay sensitivity, presumably because low level infections are frequent.

  10. Preservation of urine free catecholamines and their free O-methylated metabolites with citric acid as an alternative to hydrochloric acid for LC-MS/MS-based analyses.

    PubMed

    Peitzsch, Mirko; Pelzel, Daniela; Lattke, Peter; Siegert, Gabriele; Eisenhofer, Graeme

    2016-01-01

    Measurements of urinary fractionated metadrenalines provide a useful screening test to diagnose phaeochromocytoma. Stability of these compounds and their parent catecholamines during and after urine collection is crucial to ensure accuracy of the measurements. Stabilisation with hydrochloric acid (HCl) can promote deconjugation of sulphate-conjugated metadrenalines, indicating a need for alternative preservatives. Urine samples with an intrinsically acidic or alkaline pH (5.5-6.9 or 7.1-8.7, respectively) were used to assess stability of free catecholamines and their free O-methylated metabolites over 7 days of room temperature storage. Stabilisation with HCl was compared with ethylenediaminetetraacetic acid/metabisulphite and monobasic citric acid. Catecholamines and metabolites were measured by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Free catecholamines and their O-methylated metabolites were stable in acidic urine samples over 7 days of room temperature storage, independent of the presence or absence of any stabilisation method. In contrast, free catecholamines, but not the free O-methylated metabolites, showed rapid degradation within 24 h and continuing degradation over 7 days in urine samples with an alkaline pH. Adjustment of alkaline urine samples to a pH of 3-5 with HCl or 4.8-5.4 with citric acid completely blocked degradation of catecholamines. Ethylenediaminetetraacetic acid/metabisulphite, although reducing the extent of degradation of catecholamines in alkaline urine, was largely ineffectual as a stabiliser. Citric acid is equally effective as HCl for stabilisation of urinary free catecholamines and minimises hazards associated with use of strong inorganic acids while avoiding deconjugation of sulphate-conjugated metabolites during simultaneous LC-MS/MS measurements of free catecholamines and their free O-methylated metabolites.

  11. Unreliable alcohol testing in a shipping safety programme.

    PubMed

    Helander, Anders; Hagelberg, Charlotte Asker; Beck, Olof; Petrini, Björn

    2009-08-10

    Within a maritime alcohol and drug testing programme, a case showing an unphysiological urine ethanol concentration (235 mmol/L, 10.8 g/L) was found. The sample contained low levels of the ethanol metabolites ethyl glucuronide (EtG) and ethyl sulphate (EtS) which confirmed prior drinking, but also tested positive for the fermenting yeast Candida albicans which suggested post-sampling ethanol formation. This and other questionable cases prompted investigation of the suitability of urine alcohol testing for the intended application. Besides the routine measurements of ethanol, illicit drugs and creatinine, randomly selected ethanol-positive and ethanol-negative urines collected within the maritime programme were checked for the presence of EtG and EtS and for fungal and bacterial growth. Data on sample handling and storage was also gathered. Ten of 15 (67%) ethanol-positive and 4 of 9 (44%) ethanol-negative urines contained yeast and/or bacteria. Among the ethanol-positive cases, 4 (27%) were obviously false positives because EtG and EtS were not detected. Microbial action as the reason for false-high ethanol concentrations was indicated in other cases. When 17 bacteria-infected but fungi-negative urines were supplemented with glucose and stored for 1 week at 21 degrees C, ethanol was formed in 2 specimens containing Escherichia coli and E. coli plus P. aeruginosa. In these samples, EtG was also formed on storage while EtS was not. The routines employed for urine collection and handling within this substance abuse programme caused many false-positive identifications of alcohol use with unintended medico-legal consequences. Unpreserved urines stored without cooling should not be used for alcohol testing, given the high risk for microbial interference.

  12. Comparison of Human Papillomavirus Detections in Urine, Vulvar, and Cervical Samples from Women Attending a Colposcopy Clinic

    PubMed Central

    Gravitt, Patti E.; Dunn, S. Terence; Brown, David; Allen, Richard A.; Eby, Yolanda J.; Smith, Katie; Zuna, Rosemary E.; Zhang, Roy R.; Gold, Michael A.; Schiffman, Mark; Walker, Joan L.; Castle, Philip E.; Wentzensen, Nicolas

    2014-01-01

    While urine-based sampling for human papillomavirus (HPV) is being explored as a simple and noninvasive approach for cervical cancer screening, data comparing HPV genotyping in urine and those in cellular sampling of the cervix and vulva, and their correlation with rigorously confirmed cervical disease status, are sparse. We performed HPV genotyping on voided-urine and clinician-collected vulvar and cervical samples from 72 women undergoing colposcopy. Although urine-based HPV carcinogenic HPV detection was lower (58.3%) than cervical (73.6%) and vulvar (72.1%) detection (P = 0.05 and 0.07, respectively), the agreement of urine HPV with cervical and vulvar HPV was moderate (kappa = 0.55) and substantial (kappa = 0.62), respectively. Urine-based carcinogenic HPV detection had a clinical sensitivity of 80.8% (95% confidence interval [CI] = 60.7 to 93.5) and a specificity of 53.3% (95% CI = 37.9 to 68.3) for diagnosing cervical intraepithelial neoplasia grades 2/3 (CIN2/3) on histology; 90.0% of CIN3 was positive for urine HPV. The corresponding sensitivity and specificity values for vulvar sampling were 92% (95% CI = 74 to 99) and 40.5% (95% CI = 25.6 to 56.7), and those for cervical sampling were 96.2% (95% CI = 80.4 to 99.9) and 40% (95% CI = 25.7 to 55.7), respectively. HPV16 was the most common carcinogenic genotype detectable in 25% of urine, 33.8% of vulvar, and 31.9% of cervical samples overall, with prevalence increasing with cervical disease grade, regardless of the sampling method. Stronger cervical HPV PCR signal strengths were associated with increased frequency of urine HPV detection. In summary, the relatively lower detection rates but comparable clinical performance of urine-based HPV sampling underscore the need for larger studies to evaluate urine-based sampling for cervical cancer screening, epidemiologic studies, and postvaccination HPV disease surveillance. PMID:24197879

  13. Spectral pattern of urinary water as a biomarker of estrus in the giant panda

    NASA Astrophysics Data System (ADS)

    Kinoshita, Kodzue; Miyazaki, Mari; Morita, Hiroyuki; Vassileva, Maria; Tang, Chunxiang; Li, Desheng; Ishikawa, Osamu; Kusunoki, Hiroshi; Tsenkova, Roumiana

    2012-11-01

    Near infrared spectroscopy (NIRS) has been successfully used for non-invasive diagnosis of diseases and abnormalities where water spectral patterns are found to play an important role. The present study investigates water absorbance patterns indicative of estrus in the female giant panda. NIR spectra of urine samples were acquired from the same animal on a daily basis over three consecutive putative estrus periods. Characteristic water absorbance patterns based on 12 specific water absorbance bands were discovered, which displayed high urine spectral variation, suggesting that hydrogen-bonded water structures increase with estrus. Regression analysis of urine spectra and spectra of estrone-3-glucuronide standard concentrations at these water bands showed high correlation with estrogen levels. Cluster analysis of urine spectra grouped together estrus samples from different years. These results open a new avenue for using water structure as a molecular mirror for fast estrus detection.

  14. Spectral pattern of urinary water as a biomarker of estrus in the giant panda.

    PubMed

    Kinoshita, Kodzue; Miyazaki, Mari; Morita, Hiroyuki; Vassileva, Maria; Tang, Chunxiang; Li, Desheng; Ishikawa, Osamu; Kusunoki, Hiroshi; Tsenkova, Roumiana

    2012-01-01

    Near infrared spectroscopy (NIRS) has been successfully used for non-invasive diagnosis of diseases and abnormalities where water spectral patterns are found to play an important role. The present study investigates water absorbance patterns indicative of estrus in the female giant panda. NIR spectra of urine samples were acquired from the same animal on a daily basis over three consecutive putative estrus periods. Characteristic water absorbance patterns based on 12 specific water absorbance bands were discovered, which displayed high urine spectral variation, suggesting that hydrogen-bonded water structures increase with estrus. Regression analysis of urine spectra and spectra of estrone-3-glucuronide standard concentrations at these water bands showed high correlation with estrogen levels. Cluster analysis of urine spectra grouped together estrus samples from different years. These results open a new avenue for using water structure as a molecular mirror for fast estrus detection.

  15. Spectral pattern of urinary water as a biomarker of estrus in the giant panda

    PubMed Central

    Kinoshita, Kodzue; Miyazaki, Mari; Morita, Hiroyuki; Vassileva, Maria; Tang, Chunxiang; Li, Desheng; Ishikawa, Osamu; Kusunoki, Hiroshi; Tsenkova, Roumiana

    2012-01-01

    Near infrared spectroscopy (NIRS) has been successfully used for non-invasive diagnosis of diseases and abnormalities where water spectral patterns are found to play an important role. The present study investigates water absorbance patterns indicative of estrus in the female giant panda. NIR spectra of urine samples were acquired from the same animal on a daily basis over three consecutive putative estrus periods. Characteristic water absorbance patterns based on 12 specific water absorbance bands were discovered, which displayed high urine spectral variation, suggesting that hydrogen-bonded water structures increase with estrus. Regression analysis of urine spectra and spectra of estrone-3-glucuronide standard concentrations at these water bands showed high correlation with estrogen levels. Cluster analysis of urine spectra grouped together estrus samples from different years. These results open a new avenue for using water structure as a molecular mirror for fast estrus detection. PMID:23181188

  16. Design and use of mouse control DNA for DNA biomarker extraction and PCR detection from urine: application for transrenal Mycobacterium tuberculosis DNA detection

    PubMed Central

    Bordelon, Hali; Ricks, Keersten M.; Pask, Megan E.; Russ, Patricia K.; Solinas, Francesca; Baglia, Mark L.; Short, Philip A.; Nel, Andrew; Blackburn, Jonathan; Dheda, Keertan; Zamudio, Carlos; Cáceres, Tatiana; Wright, David W.; Haselton, Frederick R.; Pettit, April C.

    2017-01-01

    Urine samples are increasingly used for diagnosing infections including Escherichia coli, Ebola virus, and Zika virus. However, extraction and concentration of nucleic acid biomarkers from urine is necessary for many molecular detection strategies such as polymerase chain reaction (PCR). Since urine samples typically have large volumes with dilute biomarker concentrations making them prone to false negatives, another impediment for urine-based diagnostics is the establishment of appropriate controls particularly to rule out false negatives. In this study, a mouse glyceraldehyde 3-phosphate dehydrogenase (GAPDH) DNA target was added to retrospectively collected urine samples from tuberculosis (TB)-infected and TB-uninfected patients to indicate extraction of intact DNA and removal of PCR inhibitors from urine samples. We tested this design on surrogate urine samples, retrospective 1 milliliter (mL) urine samples from patients in Lima, Peru and retrospective 5 mL urine samples from patients in Cape Town, South Africa. Extraction/PCR control DNA was detectable in 97% of clinical samples with no statistically significant differences among groups. Despite the inclusion of this control, there was no difference in the amount of TB IS6110 Tr-DNA detected between TB-infected and TB-uninfected groups except for samples from known HIV-infected patients. We found a increase in TB IS6110 Tr-DNA between TB/HIV co-infected patients compared to TB-uninfected/HIV-infected patients (N=18, p=0.037). The inclusion of an extraction/PCR control DNA to indicate successful DNA extraction and removal of PCR inhibitors should be easily adaptable as a sample preparation control for other acellular sample types. PMID:28285168

  17. Design and use of mouse control DNA for DNA biomarker extraction and PCR detection from urine: Application for transrenal Mycobacterium tuberculosis DNA detection.

    PubMed

    Bordelon, Hali; Ricks, Keersten M; Pask, Megan E; Russ, Patricia K; Solinas, Francesca; Baglia, Mark L; Short, Philip A; Nel, Andrew; Blackburn, Jonathan; Dheda, Keertan; Zamudio, Carlos; Cáceres, Tatiana; Wright, David W; Haselton, Frederick R; Pettit, April C

    2017-05-01

    Urine samples are increasingly used for diagnosing infections including Escherichia coli, Ebola virus, and Zika virus. However, extraction and concentration of nucleic acid biomarkers from urine is necessary for many molecular detection strategies such as polymerase chain reaction (PCR). Since urine samples typically have large volumes with dilute biomarker concentrations making them prone to false negatives, another impediment for urine-based diagnostics is the establishment of appropriate controls particularly to rule out false negatives. In this study, a mouse glyceraldehyde 3-phosphate dehydrogenase (GAPDH) DNA target was added to retrospectively collected urine samples from tuberculosis (TB)-infected and TB-uninfected patients to indicate extraction of intact DNA and removal of PCR inhibitors from urine samples. We tested this design on surrogate urine samples, retrospective 1milliliter (mL) urine samples from patients in Lima, Peru and retrospective 5mL urine samples from patients in Cape Town, South Africa. Extraction/PCR control DNA was detectable in 97% of clinical samples with no statistically significant differences among groups. Despite the inclusion of this control, there was no difference in the amount of TB IS6110 Tr-DNA detected between TB-infected and TB-uninfected groups except for samples from known HIV-infected patients. We found an increase in TB IS6110 Tr-DNA between TB/HIV co-infected patients compared to TB-uninfected/HIV-infected patients (N=18, p=0.037). The inclusion of an extraction/PCR control DNA to indicate successful DNA extraction and removal of PCR inhibitors should be easily adaptable as a sample preparation control for other acellular sample types. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Water Consumption as Source of Arsenic, Chromium, and Mercury in Children Living in Rural Yucatan, Mexico: Blood and Urine Levels.

    PubMed

    Arcega-Cabrera, F; Fargher, L F; Oceguera-Vargas, I; Noreña-Barroso, E; Yánez-Estrada, L; Alvarado, J; González, L; Moo-Puc, R; Pérez-Herrera, N; Quesadas-Rojas, M; Pérez-Medina, S

    2017-10-01

    Studies investigating the correlation between metal content in water and metal levels in children are scarce worldwide, but especially in developing nations. Therefore, this study investigates the correlation between arsenic, chromium, and mercury concentrations in drinking and cooking water and in blood and urine samples collected from healthy and supposedly non-exposed children from a rural area in Yucatan, Mexico. Mercury in water shows concentrations above the recommended World Health Organization (WHO) value for drinking and cooking water. Also, 25% of the children show mercury in urine above the WHO recommended value. Multivariate analyses show a significant role for drinking and cooking water as a vector of exposure in children. Also, the factor analysis shows chronic exposure in the case of arsenic, as well as an ongoing detoxification process through urine in the case of mercury. Further studies should be done in order to determine other potential metal exposure pathways among children.

  19. Simple questionnaire and urine reagent strips compared to microscopy for the diagnosis of Schistosoma haematobium in a community in northern Ghana.

    PubMed

    Bogoch, Isaac I; Andrews, Jason R; Dadzie Ephraim, Richard K; Utzinger, Jürg

    2012-10-01

    To evaluate the utility of a simple questionnaire and urine reagent strip testing for the rapid diagnosis of Schistosoma haematobium in rural northern Ghana. Cross-sectional parasitological and questionnaire survey in a community in northern Ghana. Participants provided two urine specimens that were examined under a microscope using a centrifugation method. The first urine sample was additionally subjected to reagent strip testing. A short questionnaire was administered to all participants. Microscopy of urine samples obtained from 208 individuals aged 1-77 years revealed an S. haematobium prevalence of 6.8%. The presence of any blood or protein on a urine reagent strip was 100% and 42% sensitive, and 93% and 80% specific for S. haematobium diagnosis. Questionnaires were completed by 198 individuals. Self-reported haematuria showed a sensitivity of 53% and a specificity of 85%. A dichotomous two-question panel was helpful in S. haematobium diagnosis, with working and playing near the river significantly associated with S. haematobium infection (P < 0.001). The use of urine reagent strips, coupled with questions pertaining to water contact patterns, might be considered for point-of-contact diagnosis of S. haematobium where microscopy is unavailable. © 2012 Blackwell Publishing Ltd.

  20. Assessing the potential for racial bias in hair analysis for cocaine: examining the relative risk of positive outcomes when comparing urine samples to hair samples.

    PubMed

    Mieczkowski, Tom

    2011-03-20

    This article examines the conjecture that hair analysis, performed to detect cocaine use or exposure, is biased against African Americans. It does so by comparing the outcomes of 33,928 hair and 105,792 urine samples collected from both African American and white subjects. In making this comparison the analysis seeks to determine if there is a departure in rates of positive and negative outcomes when comparing the results of hair analysis for cocaine to the results from urinalysis for cocaine by racial group. It treats urine as an unbiased test. It compares both the relative ratios of positive outcomes when comparing the two groups and it calculates the relative risk of outcomes for each group for having positive or negative outcomes. The findings show that the ratios of each racial group are effectively same for hair and urine assays, and they also show that the relative risk and risk estimates for positive and negative outcomes are the same for both racial groups. Considering all samples, the cocaine positive risk estimate for the hair samples comparing the two racial groups is 3.28 and for urinalysis the risk estimate is 3.10 (Breslow-Day χ(2) .250, 1 df, p = 0.617) a non-significant difference in risk. For pre-employment samples, the cocaine positive risk estimate for the hair samples comparing the two racial groups is 3.10 and for urinalysis the risk estimate is 2.90 (Breslow-Day χ(2) .281, df = 1, p = 0.595), also a non-significant difference in risk. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  1. Ultrasound-assisted hydrolysis of conjugated parabens in human urine and their determination by UPLC-MS/MS and UPLC-HRMS.

    PubMed

    Schlittenbauer, Linda; Seiwert, Bettina; Reemtsma, Thorsten

    2016-02-01

    Parabens are preservatives widely used in personal care products, pharmaceutical formulations as well as in food, and they are considered endocrine disruptors. For application in biomonitoring studies we developed a method for the determination of eight parabens from human urine. Sample preparation was enhanced and simplified by the combination of ultrasound-assisted enzymatic hydrolysis of conjugates (glucuronide and sulfate) followed by an extraction-free cleanup step. Quantification, using deuterated parabens as internal standards, was performed by ultrahigh-performance liquid chromatography coupled to either triple-quadrupole (UPLC-QqQ) or time-of-flight (UPLC-QqTOF) mass spectrometry. Full chromatographic separation of three butyl paraben isomers was achieved. Limits of quantification for both mass analyzers ranged from 0.1 to 0.5 μg/L for methyl, ethyl, n-/isopropyl, n-/isobutyl, and benzyl paraben in 200 μL of urine sample. The method was tested for applicability and showed high precision (intra- and interday 0.9-14.5%) as well as high accuracy (relative recovery 95-132%). A total of 39 urine samples were analyzed by both mass analyzers. The results agreed well, with a trend to higher deviation at low concentrations (less than 10 μg/L). Methyl, ethyl, and n-propyl paraben were detected most frequently (in more than 87% of the samples) with median concentrations ranging from 0.8 to 16.6 μg/L. Female urine showed higher median concentrations for all parabens, which may indicate higher exposure due to lifestyle. This method permits accurate and high-throughput analysis of parabens for epidemiological studies. Further, the UPLC-QqTOF approach provides additional information on human exposure to other compounds by post-acquisition analysis.

  2. Human and Methodological Sources of Variability in the Measurement of Urinary 8-Oxo-7,8-dihydro-2′-deoxyguanosine

    PubMed Central

    Møller, Peter; Henriksen, Trine; Mistry, Vilas; Koppen, Gudrun; Rossner, Pavel; Sram, Radim J.; Weimann, Allan; Poulsen, Henrik E.; Nataf, Robert; Andreoli, Roberta; Manini, Paola; Marczylo, Tim; Lam, Patricia; Evans, Mark D.; Kasai, Hiroshi; Kawai, Kazuaki; Li, Yun-Shan; Sakai, Kazuo; Singh, Rajinder; Teichert, Friederike; Farmer, Peter B.; Rozalski, Rafal; Gackowski, Daniel; Siomek, Agnieszka; Saez, Guillermo T.; Cerda, Concha; Broberg, Karin; Lindh, Christian; Hossain, Mohammad Bakhtiar; Haghdoost, Siamak; Hu, Chiung-Wen; Chao, Mu-Rong; Wu, Kuen-Yuh; Orhan, Hilmi; Senduran, Nilufer; Smith, Raymond J.; Santella, Regina M.; Su, Yali; Cortez, Czarina; Yeh, Susan; Olinski, Ryszard; Loft, Steffen

    2013-01-01

    Abstract Aims: Urinary 8-oxo-7,8-dihydro-2′-deoxyguanosine (8-oxodG) is a widely used biomarker of oxidative stress. However, variability between chromatographic and ELISA methods hampers interpretation of data, and this variability may increase should urine composition differ between individuals, leading to assay interference. Furthermore, optimal urine sampling conditions are not well defined. We performed inter-laboratory comparisons of 8-oxodG measurement between mass spectrometric-, electrochemical- and ELISA-based methods, using common within-technique calibrants to analyze 8-oxodG-spiked phosphate-buffered saline and urine samples. We also investigated human subject- and sample collection-related variables, as potential sources of variability. Results: Chromatographic assays showed high agreement across urines from different subjects, whereas ELISAs showed far more inter-laboratory variation and generally overestimated levels, compared to the chromatographic assays. Excretion rates in timed ‘spot’ samples showed strong correlations with 24 h excretion (the ‘gold’ standard) of urinary 8-oxodG (rp 0.67–0.90), although the associations were weaker for 8-oxodG adjusted for creatinine or specific gravity (SG). The within-individual excretion of 8-oxodG varied only moderately between days (CV 17% for 24 h excretion and 20% for first void, creatinine-corrected samples). Innovation: This is the first comprehensive study of both human and methodological factors influencing 8-oxodG measurement, providing key information for future studies with this important biomarker. Conclusion: ELISA variability is greater than chromatographic assay variability, and cannot determine absolute levels of 8-oxodG. Use of standardized calibrants greatly improves intra-technique agreement and, for the chromatographic assays, importantly allows integration of results for pooled analyses. If 24 h samples are not feasible, creatinine- or SG-adjusted first morning samples are recommended. Antioxid. Redox Signal. 18, 2377–2391. PMID:23198723

  3. Measurement of Non-Invasive Blood Glucose Level Based Sensor Color TCS3200 and Arduino

    NASA Astrophysics Data System (ADS)

    Kurniadi Wardana, Humaidillah; Indahwati, Elly; Arifah Fitriyah, Lina

    2018-04-01

    Design and measurement of Arduino-based urinary (non-invasive) urine glucose using RGB tcs3200 sensor. This research was conducted by making use of the urine in diabetes patients detected by sensor colours then measured levels of colour based on the RGB colour of the urine of diabetics. The detection is done on 4 urine samples with each consisting of 3 diabetics and 1 non-diabetics. Equipment used in this research, among others, Arduino Uno, colour sensor tcs3200, LCD 16x4. The results showed that the detection of RGB values in diabetics 230 with blue and not diabetics 200 with red.

  4. GC-MS and LC-MS analysis of nerve agents in body fluids: intra-laboratory verification test using spiked plasma and urine samples.

    PubMed

    Koller, Marianne; Becker, Christian; Thiermann, Horst; Worek, Franz

    2010-05-15

    The purpose of this study was to check the applicability of different analytical methods for the identification of unknown nerve agents in human body fluids. Plasma and urine samples were spiked with nerve agents (plasma) or with their metabolites (urine) or were left blank. Seven random samples (35% of all samples) were selected for the verification test. Plasma was worked up for unchanged nerve agents and for regenerated nerve agents after fluoride-induced reactivation of nerve agent-inhibited butyrylcholinesterase. Both extracts were analysed by GC-MS. Metabolites were extracted from plasma and urine, respectively, and were analysed by LC-MS. The urinary metabolites and two blank samples could be identified without further measurements, plasma metabolites and blanks were identified in six of seven samples. The analysis of unchanged nerve agent provided five agents/blanks and the sixth agent after further investigation. The determination of the regenerated agents also provided only five clear findings during the first screening because of a rather noisy baseline. Therefore, the sample preparation was extended by a size exclusion step performed before addition of fluoride which visibly reduced baseline noise and thus improved identification of the two missing agents. The test clearly showed that verification should be performed by analysing more than one biomarker to ensure identification of the agent(s). Copyright (c) 2010 Elsevier B.V. All rights reserved.

  5. Quality assurance in the pre-analytical phase of human urine samples by (1)H NMR spectroscopy.

    PubMed

    Budde, Kathrin; Gök, Ömer-Necmi; Pietzner, Maik; Meisinger, Christine; Leitzmann, Michael; Nauck, Matthias; Köttgen, Anna; Friedrich, Nele

    2016-01-01

    Metabolomic approaches investigate changes in metabolite profiles, which may reflect changes in metabolic pathways and provide information correlated with a specific biological process or pathophysiology. High-resolution (1)H NMR spectroscopy is used to identify metabolites in biofluids and tissue samples qualitatively and quantitatively. This pre-analytical study evaluated the effects of storage time and temperature on (1)H NMR spectra from human urine in two settings. Firstly, to evaluate short time effects probably due to acute delay in sample handling and secondly, the effect of prolonged storage up to one month to find markers of sample miss-handling. A number of statistical procedures were used to assess the differences between samples stored under different conditions, including Projection to Latent Structure Discriminant Analysis (PLS-DA), non-parametric testing as well as mixed effect linear regression analysis. The results indicate that human urine samples can be stored at 10 °C for 24 h or at -80 °C for 1 month, as no relevant changes in (1)H NMR fingerprints were observed during these time periods and temperature conditions. However, some metabolites most likely of microbial origin showed alterations during prolonged storage but without facilitating classification. In conclusion, the presented protocol for urine sample handling and semi-automatic metabolite quantification is suitable for large-scale epidemiological studies. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Stability of miRNA in human urine supports its biomarker potential

    PubMed Central

    Mall, Christine; Rocke, David M; Durbin-Johnson, Blythe; Weiss, Robert H

    2013-01-01

    Aim miRNAs are showing utility as biomarkers in urologic disease, however, a rigorous evaluation of their stability in urine is lacking. Here, we evaluate the stability of miRNAs in urine under clinically relevant storage procedures. Materials & methods Eight healthy individuals provided clean catch urine samples that were stored at room temperature or at 4°C for 5 days, or subjected to ten freeze–thaw cycles at -80°C. For each condition, two miRNAs, miR-16 and miR-21, were quantitated by quantitative real-time PCR. Results All conditions demonstrated a surprising degree of stability of miRNAs in the urine: by the end of ten freeze–thaw cycles, 23–37% of the initial amount remained; over the 5-day period of storage at room temperature, 35% of the initial amount remained; and at 4°C, 42–56% of the initial amount remained. Both miRNAs also showed degradation at approximately the same rate. Conclusion miRNAs are relatively stable in urine under a variety of storage conditions, which supports their utility as urinary biomarkers. PMID:23905899

  7. A randomized trial of employment-based reinforcement of cocaine abstinence in injection drug users.

    PubMed

    Silverman, Kenneth; Wong, Conrad J; Needham, Mick; Diemer, Karly N; Knealing, Todd; Crone-Todd, Darlene; Fingerhood, Michael; Nuzzo, Paul; Kolodner, Kenneth

    2007-01-01

    High-magnitude and long-duration abstinence reinforcement can promote drug abstinence but can be difficult to finance. Employment may be a vehicle for arranging high-magnitude and long-duration abstinence reinforcement. This study determined if employment-based abstinence reinforcement could increase cocaine abstinence in adults who inject drugs and use cocaine during methadone treatment. Participants could work 4 hr every weekday in a workplace where they could earn about $10.00 per hour in vouchers; they were required to provide routine urine samples. Participants who attended the workplace and provided cocaine-positive urine samples during the initial 4 weeks were invited to work 26 weeks and were randomly assigned to an abstinence-and-work (n = 28) or work-only (n = 28) group. Abstinence-and-work participants had to provide urine samples showing cocaine abstinence to work and maintain maximum pay. Work-only participants could work independent of their urinalysis results. Abstinence-and-work participants provided more (p = .004; OR = 5.80, 95% CI = 2.03-16.56) cocaine-negative urine samples (29%) than did work-only participants (10%). Employment-based abstinence reinforcement can increase cocaine abstinence.

  8. [Usefulness of a real-time quantitative polymerase-chain reaction (PCR) assay for the diagnosis of congenital and postnatal cytomegalovirus infection].

    PubMed

    Reina, J; Weber, I; Riera, E; Busquets, M; Morales, C

    2014-05-01

    Cytomegalovirus (CMV) is the main virus causing congenital and postnatal infections in the pediatric population. The aim of this study is to evaluate the usefulness of a quantitative real-time PCR in the diagnosis of these infections using urine as a single sample. We studied all the urine samples of newborns (< 7 days) with suspected congenital infection, and urine of patients with suspected postnatal infection (urine negative at birth). Urines were simultaneously studied by cell culture, qualitative PCR (PCRc), and quantitative real-time PCR (PCRq). We analyzed 332 urine samples (270 to rule out congenital infection and 62 postnatal infections). Of the first, 22 were positive in the PCRq, 19 in the PCRc, and 17 in the culture. PCRq had a sensitivity of 100%, on comparing the culture with the rest of the techniques. Using the PCRq as a reference method, culture had a sensitivity of 77.2%, and PCRc 86.3%. In cases of postnatal infection, PCRq detected 16 positive urines, the PCRq 12, and the cell culture 10. The urines showed viral loads ranging from 2,178 to 116,641 copies/ml. The genomic amplification technique PCRq in real time was more sensitive than the other techniques evaluated. This technique should be considered as a reference (gold standard), leaving the cell culture as a second diagnostic level. The low cost and the automation of PCRq would enable the screening for CMV infection in large neonatal and postnatal populations. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  9. Detection of Genital HPV Infection Using Urine Samples: a Population Based Study in India.

    PubMed

    Sabeena, Sasidharanpillai; Bhat, Parvati; Kamath, Veena; Mathew, Mary; Aswathyraj, Sushama; Devadiga, Santhosha; Prabhu, Suresha; Hindol, Maity; Chameetachal, Akhil; Krishnan, Anjana; Arunkumar, Govindakarnavar

    2016-01-01

    Cervical cancer is the second commonest cancer among Indian women and its association with human papilloma virus (HPV) is well established. This preventable cancer accounts for the maximum number of cancer related deaths among rural Indian women. Unlike in developed countries there are no organized cervical cancer screening programmes in India due to lack of resources and manpower. To detect genital HPV infection using urine samples among asymptomatic rural women in the age group of 18-65 years. The study area chosen was Perdoor village in Udupi Taluk, Karnataka State and all the women in the age group of 18-65 years formed the study cohort. A cross sectional study was conducted by house visits and 1,305 women were enrolled in the study. After taking written informed consent a data sheet was filled and early stream random urine samples were collected, transported to a laboratory at 4OC and aliquoted. Samples were tested using nested HPV PCR with PGMY09/11 and GP5+/6+ primers. Positive cases were genotyped by sequence analysis. Study participants included 1,134 sexually active and 171 unmarried women with a mean age at marriage of 22.1 (SD=3.9) years. Study area showed high female literacy rate of 86.6%. Five urine samples tested positive for HPV DNA (0.4%). We found very low genital HPV infection rate among women from monogamous community. This is the first major population based study carried out among asymptomatic rural women to detect genital HPV infectio from Karnataka using urine samples.

  10. Smartphone-based, sensitive µPAD detection of urinary tract infection and gonorrhea.

    PubMed

    Cho, Soohee; Park, Tu San; Nahapetian, Tigran G; Yoon, Jeong-Yeol

    2015-12-15

    The presence of bacteria in urine can be used to monitor the onset or prognosis of urinary tract infection (UTI) and some sexually-transmitted diseases (STDs), such as gonorrhea. Typically, bacteria's presence in urine is confirmed by culturing samples overnight on agar plates, followed by a microscopic examination. Additionally, the presence of Escherichia coli in a urine sample can be indirectly confirmed through assaying for nitrite (generated by reducing nitrate in urine), however this is not sufficiently specific and sensitive. Species/strains identification of bacteria in a urine sample provides insight to appropriate antibiotic treatment options. In this work, a microfluidic paper analytical device (µPAD) was designed and fabricated for evaluating UTI (E. coli) and STD (Neisseria gonorrhoeae) from human urine samples. Anti-E. coli or anti-N. gonorrhoeae antibodies were conjugated to submicron particles then pre-loaded and dried in the center of each paper microfluidic channel. Human urine samples (undiluted) spiked with E. coli or N. gonorrhoeae were incubated for 5 min with 1% Tween 80. The bacteria-spiked urine samples were then introduced to the inlet of paper microfluidic channel, which flowed through the channel by capillary force. Data confirms that proteins were not filtered by μPAD, which is essential for this assay. Urobilin, the component responsible for the yellow appearance of urine and green fluorescence emission, was filtered by μPAD, resulting in significantly minimized false-positive signals. This filtration was simultaneously made during the μPAD assay and no pretreatment/purification step was necessary. Antibody-conjugated particles were immunoagglutinated at the center of the paper channel. The extent of immunoagglutination was quantified by angle-specific Mie scatter under ambient lighting conditions, utilizing a smartphone camera as a detector. The total μPAD assay time was less than 30s. The detection limit was 10 CFU/mL for both E. coli and N. gonorrhoeae, while commercially available gonorrhea rapid kit showed a detection limit of 10(6) CFU/mL. A commercially available nitrite assay test strip also had a detection limit of 10(6) CFU/mL, but this method is not antibody-based and thus not sufficiently specific. By optimizing the particle concentration, we were also able to extend the linear range of the assay up to 10(7) CFU/mL. The proposed prototype will serve as a low-cost, point-of-care, sensitive urinalysis biosensor to monitor UTI and gonorrhea from human urine. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Should acidification of urine be performed before the analysis of calcium, phosphate and magnesium in the presence of crystals?

    PubMed

    Pratumvinit, Busadee; Reesukumal, Kanit; Wongkrajang, Preechaya; Khejonnit, Varanya; Klinbua, Cherdsak; Dangneawnoi, Weerapol

    2013-11-15

    Acidification of urine has been recommended before testing for calcium, phosphate, and magnesium. We investigated the necessity of pre-analytical acidification in both crystallized and non-crystallized urine samples. From 130 urine samples obtained via routine urine analysis, 65 (50%) samples were classified as non-crystallized. All samples were divided into three groups: untreated samples, acidified samples with HCl, and acidified samples after 1h room-temperature incubation. Urine samples were measured for calcium, phosphate, magnesium, and creatinine using Modular P800 and were examined for crystals using light microscopy. In crystallized samples, acidified samples with 1h incubation had significantly higher Ca/Cr, P/Cr, and Mg/Cr than did untreated samples with mean differences of 0.04, 0.03, and 0.01 mg/mg, respectively (P<0.001). In acidified samples that were analyzed immediately, crystallized samples had lower calcium concentrations than those of acidified samples with 1h incubation and a mean difference of 0.21 mg/dl (P = 0.025). None of the sample differences which exceeded the critical difference of urinary Ca, P and Mg was observed. Acidification of urine should be performed before the measurement of Ca, P, and Mg in the presence of urinary crystals. However, the lack of an acidification process does not result in a clinically significant change. © 2013.

  12. Urine osmolality in the US population: Implications for environmental biomonitoring

    PubMed Central

    Yeh, Hung-Chieh; Lin, Yu-Sheng; Kuo, Chin-Chi; Weidemann, Darcy; Weaver, Virginia; Fadrowski, Jeffrey; Neu, Alicia; Navas-Acien, Ana

    2018-01-01

    Background For many environmental chemicals, concentrations in spot urine samples are considered valid surrogates of exposure and internal dose. To correct for urine dilution, spot urine concentrations are commonly adjusted for urinary creatinine. There are, however, several concerns about the use of urine creatinine. While urine osmolality is an attractive alternative; its characteristics and determinants in the general population remain unknown. Our objective was to describe the determinants of urine osmolality and to contrast the difference between osmolality and creatinine in urine. Methods From the National Health and Nutrition Examination Survey (NHANES) 2009–2012, 10,769 participants aged 16 years or older with measured urine osmolality and creatinine were used in the analysis. Very dilute and very concentrated urine was defined as urine creatinine lower than 0.3 g/l and higher than 3 g/l, respectively. Linear and logistic regression analyses were performed to investigate the associations of interest. Results Urine osmolality and creatinine were highly correlated (Pearson correlation coefficient = 0.75) and their respective median values were 648 mOsm/kg and 1.07 g/l. The prevalence of very dilute and very concentrated urine samples was 8.1% and 3.1%, respectively. Factors associated in the same direction with both urine osmolality and urine creatinine included age, sex, race, body mass index (BMI), hypertension, water intake, and blood osmolality. The magnitude of associations expressed as percent change was significantly stronger with creatinine than osmolality. Compared to urine creatinine, urine osmolality did not vary by diabetes status but was affected by daily total protein intake. Participants with chronic kidney disease (CKD) had significantly higher urine creatinine concentrations but lower urine osmolality. Both very dilute and concentrated urine were associated with a diverse array of sociodemographic, medical conditions, and dietary factors. For instance, females were approximately 3.3 times more likely to have urine over-dilution than male [the adjusted odds ratios (95% CI) = 3.27 (2.10–5.10)]. Conclusion Although the determinants of urine osmolality were generally similar to those of urine creatinine, the relative influence of socio-demographic and medical conditions was less on urine osmolality than on urine creatinine. Protocols for spot urine sample collection could recommend avoiding excessive and insufficient water intake before urine sampling to improve urine adequacy. The feasibility of adopting urine osmolality adjustment and water intake recommendations before providing spot urine samples for environmental biomonitoring merits further investigation. PMID:25460670

  13. Separation and quantitation of debrisoquine and 4-hydroxydebrisoquine in human urine by capillary electrophoresis and high-performance liquid chromatography.

    PubMed

    Cifuentes, A; Valencia, J; Sanz, E; Sánchez, M J; Rodríguez-Delgado, M A

    1997-08-22

    A comparative study on the use of reversed-phase high-performance liquid chromatography (RP-HPLC) and capillary electrophoresis (CE) for the determination of debrisoquine (D) and its metabolite, 4-hydroxydebrisoquine (4-HD), in human urine is presented. Four different urine pre-treatments are compared for purification of samples prior to their injection in HPLC and CE. The use of a solid-phase extraction with a C18 cartridge provides the best results for the urine sample treatment, with good recoveries, i.e., 94.5% for D and 93.4% for 4-HD, and high reproducibility, i.e., R.S.D. N = 10 values of 1.7% and 1.2%, respectively. Under our separation conditions it is shown that CE is twice as fast and provides slightly better analysis time reproducibility than HPLC for this type of sample. Both the sensitivity and peak area reproducibility are better when HPLC is used. The two techniques show good agreement when employed for determination of phenotypes for hydroxylation, which seems to corroborate the usefulness of CE for this type of study.

  14. Rapid method for direct identification of bacteria in urine and blood culture samples by matrix-assisted laser desorption ionization time-of-flight mass spectrometry: intact cell vs. extraction method.

    PubMed

    Ferreira, L; Sánchez-Juanes, F; Muñoz-Bellido, J L; González-Buitrago, J M

    2011-07-01

    Matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) is a fast and reliable technology for the identification of microorganisms with proteomics approaches. Here, we compare an intact cell method and a protein extraction method before application on the MALDI plate for the direct identification of microorganisms in both urine and blood culture samples from clinical microbiology laboratories. The results show that the intact cell method provides excellent results for urine and is a good initial method for blood cultures. The extraction method complements the intact cell method, improving microorganism identification from blood culture. Thus, we consider that MALDI-TOF MS performed directly on urine and blood culture samples, with the protocols that we propose, is a suitable technique for microorganism identification, as compared with the routine methods used in the clinical microbiology laboratory. © 2010 The Authors. Clinical Microbiology and Infection © 2010 European Society of Clinical Microbiology and Infectious Diseases.

  15. Reliable determination of new lipid peroxidation compounds as potential early Alzheimer Disease biomarkers.

    PubMed

    García-Blanco, Ana; Peña-Bautista, Carmen; Oger, Camille; Vigor, Claire; Galano, Jean-Marie; Durand, Thierry; Martín-Ibáñez, Nuria; Baquero, Miguel; Vento, Máximo; Cháfer-Pericás, Consuelo

    2018-07-01

    Lipid peroxidation plays an important role in Alzheimer Disease, so corresponding metabolites found in urine samples could be potential biomarkers. The aim of this work is to develop a reliable ultra-performance liquid chromatography-tandem mass spectrometry analytical method to determine a new set of lipid peroxidation compounds in urine samples. Excellent sensitivity was achieved with limits of detection between 0.08 and 17 nmol L -1 , which renders this method suitable to monitor analytes concentrations in real samples. The method's precision was satisfactory with coefficients of variation around 5-17% (intra-day) and 8-19% (inter-day). The accuracy of the method was assessed by analysis of spiked urine samples obtaining recoveries between 70% and 120% for most of the analytes. The utility of the described method was tested by analyzing urine samples from patients early diagnosed with mild cognitive impairment or mild dementia Alzheimer Disease following the clinical standard criteria. As preliminary results, some analytes (17(RS)-10-epi-SC-Δ 15 -11-dihomo-IsoF, PGE 2 ) and total parameters (Neuroprostanes, Isoprostanes, Isofurans) show differences between the control and the clinical groups. So, these analytes could be potential early Alzheimer Disease biomarkers assessing the patients' pro-oxidant condition. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. A pilot study of urinary microRNA as a biomarker for urothelial cancer

    PubMed Central

    Snowdon, Jaime; Boag, Sandy; Feilotter, Harriet; Izard, Jason; Siemens, D. Robert

    2013-01-01

    Objective: MicroRNAs (miRNAs) are part of a class of small ribonucleic acid (RNAs). They are important regulatory molecules, involved in several cell processes, such as developmental timing, stem cell division and apoptosis. Dysregulated miRNAs have been identified in several human malignancies, including bladder cancer tissue samples, and may confer a “tumour signature” that can be exploited for diagnostic purposes. We report on a prospective pilot study investigating the diagnostic capability of miRNAs in the urine of patients with urothelial cancer. Methods: Voided urine samples were collected from patients with urothelial carcinoma just prior to bladder tumour resection, as well as age-matched healthy control patients. Pathology demonstrated both low- and high-grade cancer. Total RNA was isolated and quantitative reverse transcriptase-polymerase chain reaction was performed on the RNA extracts using primers for 4 miRNAs shown previously to be dysregulated in solid urothelial carcinomas with RNU6B as the endogenous control. Standard urine cytology was performed on all samples in a blinded fashion. Results: Two miRNAs of interest were dysregulated in the urine from cancer patients with miR-125b showing an average 10.42-fold decrease (p < 0.01) and miR-126 showing an average 2.70-fold increase (p = 0.30) in the cancer samples compared to the normal controls. The sensitivity and specificity of the cytology on the same urine samples were 50% and 80%, respectively. Using these 2 miRNAs only, a decision-tree prediction model was generated for a validation cohort of patients yielding a specificity of 100% and a sensitivity of 80%. Discussion: This preliminary study of candidate urinary miRNA in patients with low- and high-grade urothelial cancer demonstrated a significantly improved diagnostic accuracy over cytology. These results provide rationale for further studies on discovery and validation of candidate miRNAs in voided urine and may potentially lead to the development of a non-invasive and sensitive test for bladder cancer diagnosis and prognosis. PMID:22630336

  17. Reliable Quantification of the Potential for Equations Based on Spot Urine Samples to Estimate Population Salt Intake: Protocol for a Systematic Review and Meta-Analysis.

    PubMed

    Huang, Liping; Crino, Michelle; Wu, Jason Hy; Woodward, Mark; Land, Mary-Anne; McLean, Rachael; Webster, Jacqui; Enkhtungalag, Batsaikhan; Nowson, Caryl A; Elliott, Paul; Cogswell, Mary; Toft, Ulla; Mill, Jose G; Furlanetto, Tania W; Ilich, Jasminka Z; Hong, Yet Hoi; Cohall, Damian; Luzardo, Leonella; Noboa, Oscar; Holm, Ellen; Gerbes, Alexander L; Senousy, Bahaa; Pinar Kara, Sonat; Brewster, Lizzy M; Ueshima, Hirotsugu; Subramanian, Srinivas; Teo, Boon Wee; Allen, Norrina; Choudhury, Sohel Reza; Polonia, Jorge; Yasuda, Yoshinari; Campbell, Norm Rc; Neal, Bruce; Petersen, Kristina S

    2016-09-21

    Methods based on spot urine samples (a single sample at one time-point) have been identified as a possible alternative approach to 24-hour urine samples for determining mean population salt intake. The aim of this study is to identify a reliable method for estimating mean population salt intake from spot urine samples. This will be done by comparing the performance of existing equations against one other and against estimates derived from 24-hour urine samples. The effects of factors such as ethnicity, sex, age, body mass index, antihypertensive drug use, health status, and timing of spot urine collection will be explored. The capacity of spot urine samples to measure change in salt intake over time will also be determined. Finally, we aim to develop a novel equation (or equations) that performs better than existing equations to estimate mean population salt intake. A systematic review and meta-analysis of individual participant data will be conducted. A search has been conducted to identify human studies that report salt (or sodium) excretion based upon 24-hour urine samples and spot urine samples. There were no restrictions on language, study sample size, or characteristics of the study population. MEDLINE via OvidSP (1946-present), Premedline via OvidSP, EMBASE, Global Health via OvidSP (1910-present), and the Cochrane Library were searched, and two reviewers identified eligible studies. The authors of these studies will be invited to contribute data according to a standard format. Individual participant records will be compiled and a series of analyses will be completed to: (1) compare existing equations for estimating 24-hour salt intake from spot urine samples with 24-hour urine samples, and assess the degree of bias according to key demographic and clinical characteristics; (2) assess the reliability of using spot urine samples to measure population changes in salt intake overtime; and (3) develop a novel equation that performs better than existing equations to estimate mean population salt intake. The search strategy identified 538 records; 100 records were obtained for review in full text and 73 have been confirmed as eligible. In addition, 68 abstracts were identified, some of which may contain data eligible for inclusion. Individual participant data will be requested from the authors of eligible studies. Many equations for estimating salt intake from spot urine samples have been developed and validated, although most have been studied in very specific settings. This meta-analysis of individual participant data will enable a much broader understanding of the capacity for spot urine samples to estimate population salt intake.

  18. Pathogens and pharmaceuticals in source-separated urine in eThekwini, South Africa.

    PubMed

    Bischel, Heather N; Özel Duygan, Birge D; Strande, Linda; McArdell, Christa S; Udert, Kai M; Kohn, Tamar

    2015-11-15

    In eThekwini, South Africa, the production of agricultural fertilizers from human urine collected from urine-diverting dry toilets is being evaluated at a municipality scale as a way to help finance a decentralized, dry sanitation system. The present study aimed to assess a range of human and environmental health hazards in source-separated urine, which was presumed to be contaminated with feces, by evaluating the presence of human pathogens, pharmaceuticals, and an antibiotic resistance gene. Composite urine samples from households enrolled in a urine collection trial were obtained from urine storage tanks installed in three regions of eThekwini. Polymerase chain reaction (PCR) assays targeted 9 viral and 10 bacterial human pathogens transmitted by the fecal-oral route. The most frequently detected viral pathogens were JC polyomavirus, rotavirus, and human adenovirus in 100%, 34% and 31% of samples, respectively. Aeromonas spp. and Shigella spp. were frequently detected gram negative bacteria, in 94% and 61% of samples, respectively. The gram positive bacterium, Clostridium perfringens, which is known to survive for extended times in urine, was found in 72% of samples. A screening of 41 trace organic compounds in the urine facilitated selection of 12 priority pharmaceuticals for further evaluation. The antibiotics sulfamethoxazole and trimethoprim, which are frequently prescribed as prophylaxis for HIV-positive patients, were detected in 95% and 85% of samples, reaching maximum concentrations of 6800 μg/L and 1280 μg/L, respectively. The antiretroviral drug emtricitabine was also detected in 40% of urine samples. A sulfonamide antibiotic resistance gene (sul1) was detected in 100% of urine samples. By coupling analysis of pathogens and pharmaceuticals in geographically dispersed samples in eThekwini, this study reveals a range of human and environmental health hazards in urine intended for fertilizer production. Collection of urine offers the benefit of sequestering contaminants from environmental release and allows for targeted treatment of potential health hazards prior to agricultural application. The efficacy of pathogen and pharmaceutical inactivation, transformation or removal during urine nutrient recovery processes is thus briefly reviewed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Utility of ELISA screening for the monitoring of abstinence from illegal and legal drugs in hair and urine.

    PubMed

    Agius, Ronald; Nadulski, Thomas

    2014-06-01

    Amphetamines, cannabinoids, cocaine, opiates, methadone, and benzodiazepines in authentic hair samples with drug concentrations around the medical and psychological assessment (MPA) guidelines cut-offs were screened by LUCIO-direct ELISA kits. Following confirmation of all positive and a significant number of negatively screened samples with gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods accredited for forensic purposes. Receiver operating characteristics (ROC) were plotted and the area under the curve (AUC) and overall misclassification rate (OMR) were calculated and compared to those obtained for the same drug classes in urine. While fulfilling the validation criteria of the German forensic guidelines, for almost all screening tests in hair and urine the AUC were greater than 0.8, indicating good to excellent performance. Moreover the AUC calculated for the detection of drugs in hair did not differ significantly to the AUC calculated for the detection of the same drug classes in urine, thus showing a comparable screening performance to the well accepted, previously published application of the same ELISAs for the detection of drugs at unconventionally low cut-offs in urine. For the first time, the validation of the immunoassay tests for the complete 6-drug panel MPA profile in hair and urine using a large population of authentic hair and urine samples with drug concentrations around MPA cut-offs, lower than conventional clinical or workplace drug testing guidelines cut-offs as well as those suggested by the Society of hair testing (SoHT) is presented. Copyright © 2014 John Wiley & Sons, Ltd.

  20. Comparison between Indirect Immunofluorescence Assay and Shell Vial Culture for Detection of Mumps Virus from Clinical Samples

    PubMed Central

    Reina, Jordi; Ballesteros, Francisca; Ruiz de Gopegui, Enrique; Munar, Maria; Mari, Margarita

    2003-01-01

    We report a prospective comparison of the efficacies of an indirect immunofluorescence assay (IFA) and shell vial culture (SVC) of throat swab and urine samples from patients with mumps. Throat swab samples were used for the IFA; the urine samples and throat swabs were inoculated into vials of Vero cells. We studied 62 patients by using 62 throat swabs and 50 urine samples (50 patients with both samples). Sixty (96.7%) throat samples were positive in the SVC, and 61 (98.3%) were positive in the IFA. For the 50 patients from whom both samples were available, the IFA was positive in 50 (100%) cases, the urine sample was positive in 49 (98%) cases, and the throat swab was positive in 48 (96%) cases (P > 0.05). This comparison of throat swabs and urine samples has shown that the two clinical samples are similar in efficacy. PMID:14605158

  1. Comparison between Urine and Cervical Samples for HPV DNA Detection and Typing in Young Women in Colombia.

    PubMed

    Cómbita, Alba Lucía; Gheit, Tarik; González, Paula; Puerto, Devi; Murillo, Raúl Hernando; Montoya, Luisa; Vorsters, Alex; Van Keer, Severien; Van Damme, Pierre; Tommasino, Massimo; Hernández-Suárez, Gustavo; Sánchez, Laura; Herrero, Rolando; Wiesner, Carolina

    2016-09-01

    Urine sampling for HPV DNA detection has been proposed as an effective method for monitoring the impact of HPV vaccination programs; however, conflicting results have been reported. The goal of this study was to evaluate the performance of optimized urine HPV DNA testing in women aged 19 to 25 years. Optimization process included the use of first void urine, immediate mixing of urine with DNA preservative, and the concentration of all HPV DNA, including cell-free DNA fragments. Urine and cervical samples were collected from 535 young women attending cervical screening at health centers from two Colombian cities. HPV DNA detection and genotyping was performed using an HPV type-specific multiplex genotyping assay, which combines multiplex polymerase chain reaction with bead-based Luminex technology. Concordance between HPV DNA detection in urine and cervical samples was determined using kappa statistics and McNemar tests. The accuracy of HPV DNA testing in urine samples was evaluated measuring sensitivity and specificity using as reference the results obtained from cervical samples. Statistical analysis was performed using STATA11.2 software. The findings revealed an overall HPV prevalence of 60.00% in cervical samples and 64.72% in urine samples, HPV-16 being the most frequent HPV type detected in both specimens. Moreover, our results indicate that detection of HPV DNA in first void urine provides similar results to those obtained with cervical samples and can be used to monitor HPV vaccination trials and programs as evidenced by the substantial concordance found for the detection of the four vaccine types. Cancer Prev Res; 9(9); 766-71. ©2016 AACR. ©2016 American Association for Cancer Research.

  2. A method for estimating radioactive cesium concentrations in cattle blood using urine samples.

    PubMed

    Sato, Itaru; Yamagishi, Ryoma; Sasaki, Jun; Satoh, Hiroshi; Miura, Kiyoshi; Kikuchi, Kaoru; Otani, Kumiko; Okada, Keiji

    2017-12-01

    In the region contaminated by the Fukushima nuclear accident, radioactive contamination of live cattle should be checked before slaughter. In this study, we establish a precise method for estimating radioactive cesium concentrations in cattle blood using urine samples. Blood and urine samples were collected from a total of 71 cattle on two farms in the 'difficult-to-return zone'. Urine 137 Cs, specific gravity, electrical conductivity, pH, sodium, potassium, calcium, and creatinine were measured and various estimation methods for blood 137 Cs were tested. The average error rate of the estimation was 54.2% without correction. Correcting for urine creatinine, specific gravity, electrical conductivity, or potassium improved the precision of the estimation. Correcting for specific gravity using the following formula gave the most precise estimate (average error rate = 16.9%): [blood 137 Cs] = [urinary 137 Cs]/([specific gravity] - 1)/329. Urine samples are faster to measure than blood samples because urine can be obtained in larger quantities and has a higher 137 Cs concentration than blood. These advantages of urine and the estimation precision demonstrated in our study, indicate that estimation of blood 137 Cs using urine samples is a practical means of monitoring radioactive contamination in live cattle. © 2017 Japanese Society of Animal Science.

  3. Long-term frozen storage of urine samples: a trouble to get PCR results in Schistosoma spp. DNA detection?

    PubMed

    Fernández-Soto, Pedro; Velasco Tirado, Virginia; Carranza Rodríguez, Cristina; Pérez-Arellano, José Luis; Muro, Antonio

    2013-01-01

    Human schistosomiasis remains a serious worldwide public health problem. At present, a sensitive and specific assay for routine diagnosis of schistosome infection is not yet available. The potential for detecting schistosome-derived DNA by PCR-based methods in human clinical samples is currently being investigated as a diagnostic tool with potential application in routine schistosomiasis diagnosis. Collection of diagnostic samples such as stool or blood is usually difficult in some populations. However, urine is a biological sample that can be collected in a non-invasive method, easy to get from people of all ages and easy in management, but as a sample for PCR diagnosis is still not widely used. This could be due to the high variability in the reported efficiency of detection as a result of the high variation in urine samples' storage or conditions for handling and DNA preservation and extraction methods. We evaluate different commercial DNA extraction methods from a series of long-term frozen storage human urine samples from patients with parasitological confirmed schistosomiasis in order to assess the PCR effectiveness for Schistosoma spp. detection. Patients urine samples were frozen for 18 months up to 7 years until use. Results were compared with those obtained in PCR assays using fresh healthy human urine artificially contaminated with Schistosoma mansoni DNA and urine samples from mice experimentally infected with S. mansoni cercariae stored frozen for at least 12 months before use. PCR results in fresh human artificial urine samples using different DNA based extraction methods were much more effective than those obtained when long-term frozen human urine samples were used as the source of DNA template. Long-term frozen human urine samples are probably not a good source for DNA extraction for use as a template in PCR detection of Schistosoma spp., regardless of the DNA method of extraction used.

  4. The olfactory hole-board test in rats: a new paradigm to study aversion and preferences to odors

    PubMed Central

    Wernecke, Kerstin E. A.; Fendt, Markus

    2015-01-01

    Odors of biological relevance (e.g., predator odors, sex odors) are known to effectively influence basic survival needs of rodents such as anti-predatory defensiveness and mating behaviors. Research focused on the effects of these odors on rats’ behavior mostly includes multi-trial paradigms where animals experience single odor exposures in subsequent, separated experimental sessions. In the present study, we introduce a modification of the olfactory hole-board test that allows studying the effects of different odors on rats’ behavior within single trials. First, we demonstrated that the corner holes of the hole-board were preferentially visited by rats. The placement of different odors under the corner holes changed this hole preference. We showed that holes with carnivore urine samples were avoided, while corner holes with female rat urine samples were preferred. Furthermore, corner holes with urine samples from a carnivore, herbivore, and omnivore were differentially visited indicating that rats can discriminate these odors. To test whether anxiolytic treatment specifically modulates the avoidance of carnivore urine holes, we treated rats with buspirone. Buspirone treatment completely abolished the avoidance of carnivore urine holes. Taken together, our findings indicate that the olfactory hole-board test is a valuable tool for measuring avoidance and preference responses to biologically relevant odors. PMID:26379516

  5. Urinary proteomics in renal pathophysiology: Impact of proteinuria.

    PubMed

    Sancho-Martínez, Sandra M; Prieto-García, Laura; Blanco-Gozalo, Víctor; Fontecha-Barriuso, Miguel; López-Novoa, José M; López-Hernández, Francisco J

    2015-06-01

    Urinary differential proteomics is used to study renal pathophysiological mechanisms, find novel markers of biological processes and renal diseases, and stratify patients according to proteomic profiles. The proteomic procedure determines the pathophysiological meaning and clinical relevance of results. Urine samples for differential proteomic studies are usually normalized by protein content, regardless of its pathophysiological characteristics. In the field of nephrology, this approach translates into the comparison of a different fraction of the total daily urine output between proteinuric and nonproteinuric samples. Accordingly, alterations in the level of specific proteins found by this method reflect the relative presence of individual proteins in the urine; but they do not necessarily show alterations in their daily excretion, which is a key parameter for the understanding of the pathophysiological meaning of urinary components. For renal pathophysiology studies and clinical biomarker identification or determination, an alternative proteomic concept providing complementary information is based on sample normalization by daily urine output, which directly informs on changes in the daily excretion of individual proteins. This is clinically important because daily excretion (rather than absolute or relative concentration) is the only self-normalized way to evaluate the real meaning of urinary parameters, which is also independent of urine concentration. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Cross validation of gas chromatography-flame photometric detection and gas chromatography-mass spectrometry methods for measuring dialkylphosphate metabolites of organophosphate pesticides in human urine.

    PubMed

    Prapamontol, Tippawan; Sutan, Kunrunya; Laoyang, Sompong; Hongsibsong, Surat; Lee, Grace; Yano, Yukiko; Hunter, Ronald Elton; Ryan, P Barry; Barr, Dana Boyd; Panuwet, Parinya

    2014-01-01

    We report two analytical methods for the measurement of dialkylphosphate (DAP) metabolites of organophosphate pesticides in human urine. These methods were independently developed/modified and implemented in two separate laboratories and cross validated. The aim was to develop simple, cost effective, and reliable methods that could use available resources and sample matrices in Thailand and the United States. While several methods already exist, we found that direct application of these methods required modification of sample preparation and chromatographic conditions to render accurate, reliable data. The problems encountered with existing methods were attributable to urinary matrix interferences, and differences in the pH of urine samples and reagents used during the extraction and derivatization processes. Thus, we provide information on key parameters that require attention during method modification and execution that affect the ruggedness of the methods. The methods presented here employ gas chromatography (GC) coupled with either flame photometric detection (FPD) or electron impact ionization-mass spectrometry (EI-MS) with isotopic dilution quantification. The limits of detection were reported from 0.10ng/mL urine to 2.5ng/mL urine (for GC-FPD), while the limits of quantification were reported from 0.25ng/mL urine to 2.5ng/mL urine (for GC-MS), for all six common DAP metabolites (i.e., dimethylphosphate, dimethylthiophosphate, dimethyldithiophosphate, diethylphosphate, diethylthiophosphate, and diethyldithiophosphate). Each method showed a relative recovery range of 94-119% (for GC-FPD) and 92-103% (for GC-MS), and relative standard deviations (RSD) of less than 20%. Cross-validation was performed on the same set of urine samples (n=46) collected from pregnant women residing in the agricultural areas of northern Thailand. The results from split sample analysis from both laboratories agreed well for each metabolite, suggesting that each method can produce comparable data. In addition, results from analyses of specimens from the German External Quality Assessment Scheme (G-EQUAS) suggested that the GC-FPD method produced accurate results that can be reasonably compared to other studies. Copyright © 2013 Elsevier GmbH. All rights reserved.

  7. Glycosaminoglycan and transforming growth factor beta1 changes in human plasma and urine during the menstrual cycle, in vitro fertilization treatment, and pregnancy.

    PubMed

    De Muro, Pierina; Capobianco, Giampiero; Formato, Marilena; Lepedda, Antonio Junior; Cherchi, Gian Mario; Gordini, Laila; Dessole, Salvatore

    2009-07-01

    To evaluate transforming growth factor beta1 (TGF-beta1) and glycosaminoglycans (GAG) changes in human plasma and urine during the menstrual cycle, IVF-ET, and pregnancy. Prospective clinical study. University hospital. Thirteen women with apparently normal menstrual cycle (group 1); 18 women undergoing IVF-ET (group 2); and 14 low-risk pregnant women (group 3). We assayed plasma and urine concentrations of TGF-beta1, urine content, and distribution of GAG. Blood and urine samples were collected during days 2 to 3, 12 to 13, and 23 to 24 in group 1; in group 2, samples were obtained at menstrual phase, oocyte pick-up day, and 15 days after ET; in group 3, samples were obtained during gestational weeks 10-12, 22-24, and 30-32 and 1 month after delivery. Changes in TGF-beta1 and GAG content. The mean value of total urinary trypsin inhibitor/chondroitin sulfate (UTI/CS) showed a distinct peak at day 12 of the menstrual cycle in the fertile women in whom we monitored the ovulatory period. In the IVF-ET group, GAG distribution and TGF-beta1 levels showed significant differences during the cycle. We observed increased levels of plasma TGF-beta1 15 days after ET. A significant increase of total UTI/CS value with increasing gestation was detected. Transforming growth factor beta1 and GAG levels could represent an additional tool to monitor reproductive events and could be useful, noninvasive markers of ovulation and ongoing pregnancy.

  8. Development of a purification procedure for the isolation of nucleosides from urine prior to mass spectrometric analysis.

    PubMed

    Dudley, E; El-Shakawi, S; Games, D E; Newton, R P

    2000-03-01

    A chromatographic separation of nucleosides from urine has been developed in order to facilitate their mass spectrometric analysis for clinical diagnosis. A number of chromatographic resins were studied in order to develop an effective and efficient purification procedure. The optimized sequential protocol comprises a centrifugation, acidification and neutralization step, followed by application of an affinity chromatographic column and finally further separation on an acidic cation exchange column and a basic anion exchanger. This scheme shows effective clean-up of a standard radiolabelled nucleoside with a recovery of 92.5%, and recovery of nucleosides added to urine samples before extraction showed recoveries of 72-82%.

  9. Determination of the MRI contrast agent Gd-DTPA by SEC-ICP-MS.

    PubMed

    Loreti, Valeria; Bettmer, Jörg

    2004-08-01

    The simultaneous determination of Gd(3+) and Gd-DTPA (DTPA: diethylenetriamino-pentaacetic acid), often used as contrast agent, is described. The proposed approach combines size-exclusion chromatography (SEC) and inductively coupled plasma-mass spectrometry (ICP-MS) for element-selective detection in order to determine also high-molecular Gd-complexes if present. This method was applied to the analysis of urine samples of a patient to whom Gd-DTPA was intravenously administered. The results showed that no conversion or adsorption of Gd-DTPA could be observed in any sample, even free Gd(3+) could not be detected. Urine excretion behaviour was monitored and it was proved that Gd-DTPA was almost completely (>99%) excreted by urination within one day. Traces of Gd-DTPA could be measured in hair samples, but extraction with tetramethylammonium hydroxide (TMAH) resulted in degradation of Gd-DTPA.

  10. Prevalence of vaginal infections and associated lifestyles of students in the university of Cape Coast, Ghana

    PubMed Central

    Aubyn, Gloria Baaba; Tagoe, Daniel Nii Aryee

    2013-01-01

    Objective To determine the prevalence of vaginal infections and associated lifestyles of students visiting the University of Cape Coast Hospital. Methods Fifty female students presenting with clinical symptoms of vaginitis were sampled. One hundred samples made up of 50 urine and 50 higher vaginal swabs (HVS) were obtained from patients and questionnaire administered. Samples were wet prepared, examined microscopically, and cultured on blood and chocolate agars for 24 h at (35±2) °C. Colonial morphology, Gram reactions and biochemical tests were used for the identification of isolates. Results There were high percentages of pus cells (64%), epithelial cells (62%) and yeast cells (56%) in all urine samples. Bacterial isolates included Staphylococcus aureus (28%) and (22%), Klebsiella spp. (6%) and (4%) in urine and HVS samples respectively; Escherichia coli in urine (18%) and Candida in HVS (16%). The overall prevalence of vaginitis was 66%, including bacterial vaginosis 28%, Candida infection 22% and co-infection of bacterial and Candida 16%. Lifestyle data showed all sampled students were sexually active, 48% used contraceptives, 54% used antimicrobial agents, and 92% prefered wearing of trousers and shorts. Conclusions The present study indicates prevalence of vaginal infection among female students, which strongly correlates with student lifestyle. Education on lifestyle modifications will go a long way in reducing the prevalence of vaginitis.

  11. Effect of urine creatinine level during pregnancy on dipstick test.

    PubMed

    Baba, Yosuke; Furuta, Itsuko; Zhai, Tianyue; Ohkuchi, Akihide; Yamada, Takahiro; Takahashi, Kayo; Matsubara, Shigeki; Minakami, Hisanori

    2017-06-01

    Dipstick results for proteinuria are affected by urine concentration, and thus urine creatinine concentration ([Cr]). This study was performed to determine whether spot urine [Cr] changes significantly during pregnancy, leading to a significantly different false-negative rate (FNR) on dipstick test between trimester. The [Cr] and protein concentrations ([P]) were analyzed in 631 spot urine samples with negative/equivocal dipstick from 425 pregnant women. False-negative dipstick was defined as [P] : [Cr] ratio (P/Cr) > 0.27 mg/mg. Median [Cr] was 117 mg/dL (range, 6.5-326 mg/dL), 72 mg/dL (range, 4.3-477 mg/dL), and 73 mg/dL (range, 8.4-396 mg/dL) in the first (n = 96), second (n = 344), and third (n = 191) trimester urine samples, respectively (P = 0.000, Kruskal-Wallis). Both [P] and P/Cr increased significantly with advancing gestation. FNR 9.4% (18/191) in the third trimester was significantly higher than that of 0.0% (0/96) in the second trimester and that of 0.5% (2/344) in the third trimester. In the 20 urine samples with false-negative dipstick, median [Cr] was 47.0 mg/dL (range, 11.0-358 mg/dL) and the proportion of samples with dilute urine, that is, [Cr] <47 mg/dL, was significantly higher than in the remaining 611 urine samples (50%, 10/20 vs 28%, 174/611, respectively, P = 0.046). Urine samples in the second and third trimesters were more likely to be diluted compared with the first trimester. This was associated with high FNR in third trimester urine samples. © 2017 Japan Society of Obstetrics and Gynecology.

  12. Prevalence of urinary tract infection (UTI) in sequential acutely unwell children presenting in primary care: exploratory study.

    PubMed

    O'Brien, Kathryn; Stanton, Naomi; Edwards, Adrian; Hood, Kerenza; Butler, Christopher C

    2011-03-01

    Due to the non-specific nature of symptoms of UTI in children and low levels of urine sampling, the prevalence of UTI amongst acutely ill children in primary care is unknown. To undertake an exploratory study of acutely ill children consulting in primary care, determine the feasibility of obtaining urine samples, and describe presenting symptoms and signs, and the proportion with UTI. Exploratory, observational study. Four general practices in South Wales. A total of 99 sequential attendees with acute illness aged less than five years. UTI defined by >10(5) organisms/ml on laboratory culture of urine. Urine samples were obtained in 75 (76%) children. Three (4%) met microbiological criteria for UTI. GPs indicated they would not normally have obtained urine samples in any of these three children. However, all had received antibiotics for suspected alternative infections. Urine sample collection is feasible from the majority of acutely ill children in primary care, including infants. Some cases of UTI may be missed if children thought to have an alternative site of infection are excluded from urine sampling. A larger study is needed to more accurately determine the prevalence of UTI in children consulting with acute illness in primary care, and to explore which symptoms and signs might help clinicians effectively target urine sampling.

  13. Critical study of common conditions of storage of glucocorticoids and catecholamines in 24-h urine collected during resting and exercising conditions.

    PubMed

    Gouarne, C; Foury, A; Duclos, M

    2004-10-01

    Except immediate freezing of the samples, no practical method has been validated for preservation of glucocorticoids and catecholamines in 24-h urine collection. Furthermore, the influence of urine storage at bladder temperature during periods of different lengths and the effect of prior exercise on preservation of these hormones in the bladder have not been investigated until now. Ten healthy volunteers collected their urine both after a resting and after an exercise session. Urine was aliquoted into tubes which were stored during 24 h in the presence or in the absence of preservatives and at different temperatures. Two samples were stored either 3 or 9 h at 37 degrees C (bladder temperature) without additive. When collecting 24-h urine samples for glucocorticoids determination, sample can be stored at room temperature during the 24-h collection period without compromising glucocorticoids preservation. When collecting 24-h urine samples for catecholamines determination, samples have to be chilled without preservative during the whole of the collection period. If the samples have to be stored at room temperature, HCl should be used. Moreover, we report for the first time that catecholamines can be degraded in the bladder and therefore that subjects should urinate every 3 h during either a resting or an exercising day.

  14. Long-Term Frozen Storage of Urine Samples: A Trouble to Get PCR Results in Schistosoma spp. DNA Detection?

    PubMed Central

    Fernández-Soto, Pedro; Velasco Tirado, Virginia; Carranza Rodríguez, Cristina; Pérez-Arellano, José Luis; Muro, Antonio

    2013-01-01

    Background Human schistosomiasis remains a serious worldwide public health problem. At present, a sensitive and specific assay for routine diagnosis of schistosome infection is not yet available. The potential for detecting schistosome-derived DNA by PCR-based methods in human clinical samples is currently being investigated as a diagnostic tool with potential application in routine schistosomiasis diagnosis. Collection of diagnostic samples such as stool or blood is usually difficult in some populations. However, urine is a biological sample that can be collected in a non-invasive method, easy to get from people of all ages and easy in management, but as a sample for PCR diagnosis is still not widely used. This could be due to the high variability in the reported efficiency of detection as a result of the high variation in urine samples’ storage or conditions for handling and DNA preservation and extraction methods. Methodology/Principal Findings We evaluate different commercial DNA extraction methods from a series of long-term frozen storage human urine samples from patients with parasitological confirmed schistosomiasis in order to assess the PCR effectiveness for Schistosoma spp. detection. Patientś urine samples were frozen for 18 months up to 7 years until use. Results were compared with those obtained in PCR assays using fresh healthy human urine artificially contaminated with Schistosoma mansoni DNA and urine samples from mice experimentally infected with S. mansoni cercariae stored frozen for at least 12 months before use. PCR results in fresh human artificial urine samples using different DNA based extraction methods were much more effective than those obtained when long-term frozen human urine samples were used as the source of DNA template. Conclusions/Significance Long-term frozen human urine samples are probably not a good source for DNA extraction for use as a template in PCR detection of Schistosoma spp., regardless of the DNA method of extraction used. PMID:23613907

  15. Evaluation of the bioNexia Legionella Test, Including Impact of Incubation Time Extension, for Detection of Legionella pneumophila Serogroup 1 Antigen in Urine.

    PubMed

    Badoux, Paul; Euser, Sjoerd M; Bruin, Jacob P; Mulder, Patrick P G; Yzerman, Ed P F

    2017-06-01

    In this study, we compared the bioNexia test (bioMérieux, Marcy-l'Étoile, France), a new immunochromatographic assay for the detection of Legionella pneumophila serogroup 1 in urine, with the BinaxNOW urinary antigen test (Alere, Waltham, Massachusetts, USA). After 15 min of incubation (in accordance with the manufacturers' instructions), the sensitivities and specificities were, respectively, 76.5% and 97.2% for the bioNexia test and 87.1% and 100% for the BinaxNOW test. After a prolonged incubation time of 60 min, the sensitivities and specificities increased to, respectively, 89.4% and 97.2% for the bioNexia test and 91.8% and 100% for the BinaxNOW test. When the tests were read after 15 min, the concentration of discrepant urine samples increased the sensitivities to 94.1% for both tests. In conclusion, we found that although the bioNexia test showed lower sensitivity for the detection of L. pneumophila antigen in nonconcentrated urine compared to the BinaxNOW test, a prolonged incubation time as well as the use of concentrated samples showed comparable sensitivities for both tests. Copyright © 2017 American Society for Microbiology.

  16. Long-term urine biobanking: storage stability of clinical chemical parameters under moderate freezing conditions without use of preservatives.

    PubMed

    Remer, Thomas; Montenegro-Bethancourt, Gabriela; Shi, Lijie

    2014-12-01

    To examine the long-term stability and validity of analyte concentrations of 21 clinical biochemistry parameters in 24-h urine samples stored for 12 or 15 yr at -22°C and preservative free. Healthy children's 24-h urine samples in which the respective analytes had been measured shortly after sample collection (baseline) were reanalyzed. Second measurement was performed after 12 yr (organic acids) and 15 yr (creatinine, urea, osmolality, iodine, nitrogen, anions, cations, acid-base parameters) with the same analytical methodology. Paired comparisons and correlations between the baseline and repeated measurements were done. Recovery rates were calculated. More than half of the analytes (creatinine, urea, iodine, nitrogen, sodium, potassium, magnesium, calcium, ammonium, bicarbonate, citric & uric acid) showed measurement values after >10 yr of storage not significantly different from baseline. 15 of the 21 parameters were highly correlated (r=0.99) between baseline and second measurement. Poorest correlation was r=0.77 for oxalate. Recovery ranged from 73% (oxalate) to 105% (phosphate). Our results suggest high long-term stability and measurement validity for numerous clinical chemistry parameters stored at -22°C without addition of any urine preservative. Prospective storage of urine aliquots at -22°C for periods even exceeding 10 yr, appears to be an acceptable and valid tool in epidemiological settings for later quantification of several urine analytes. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  17. Elevated Urine Levels of Macrophage Migration Inhibitory Factor in Inflammatory Bladder Conditions: A Potential Biomarker for a Subgroup of Interstitial Cystitis/Bladder Pain Syndrome Patients.

    PubMed

    Vera, Pedro L; Preston, David M; Moldwin, Robert M; Erickson, Deborah R; Mowlazadeh, Behzad; Ma, Fei; Kouzoukas, Dimitrios E; Meyer-Siegler, Katherine L; Fall, Magnus

    2018-06-01

    To investigate whether urinary levels of macrophage migration inhibitory factor (MIF) are elevated in interstitial cystitis/bladder pain syndrome (IC/BPS) patients with Hunner lesions and also whether urine MIF is elevated in other forms of inflammatory cystitis. Urine samples were assayed for MIF by enzyme-linked immunosorbent assay. Urine samples from 3 female groups were examined: IC/BPS patients without (N = 55) and with Hunner lesions (N = 43), and non-IC/BPS patients (N = 100; control group; no history of IC/BPS; cancer or recent bacterial cystitis). Urine samples from 3 male groups were examined: patients with bacterial cystitis (N = 50), radiation cystitis (N = 18) and noncystitis patients (N = 119; control group; negative for bacterial cystitis). Urine MIF (mean MIF pg/mL ±  standard error of the mean) was increased in female IC/BPS patients with Hunner lesions (2159 ± 435.3) compared with IC/BPS patients without Hunner lesions (460 ± 114.5) or non-IC/BPS patients (414 ± 47.6). Receiver operating curve analyses showed that urine MIF levels discriminated between the 2 IC groups (area under the curve = 72%; confidence interval 61%-82%). Male patients with bacterial and radiation cystitis had elevated urine MIF levels (2839 ± 757.1 and 4404 ± 1548.1, respectively) compared with noncystitis patients (681 ± 75.2). Urine MIF is elevated in IC/BPS patients with Hunner lesions and also in patients with other bladder inflammatory and painful conditions. MIF may also serve as a noninvasive biomarker to select IC/BPS patients more accurately for endoscopic evaluation and possible anti-inflammatory treatment. Copyright © 2018 Elsevier Inc. All rights reserved.

  18. Urine phenobarbital drug screening: potential use for compliance assessment in neonates.

    PubMed

    Guillet, Ronnie; Kwon, Jennifer M; Chen, Sixaio; McDermott, Michael P

    2012-02-01

    This study was done to determine if urine phenobarbital measurements provide a reliable indicator of presence of the drug in neonates. Urine was collected from neonates treated with phenobarbital for clinical indications within 4 to 6 hours of clinically indicated collection of serum phenobarbital levels. Urine samples were also collected from control neonates not treated with phenobarbital. One aliquot was assayed fresh, another frozen at -30°C and assayed 1 to 3 months later. Phenobarbital was assayed using the ONLINE TDM Roche/Hitachi automated clinical chemistry analyzer. Serum and urine concentrations were compared as were fresh and frozen urine measurements. Serum phenobarbital ranged from 5.6 to 52.7 μg/mL. Matched urine samples were 56.6 ± 12.5% of the serum level. Frozen samples were 98.3 ± 8.0% of the fresh samples. Urine phenobarbital concentrations, either fresh or frozen, can be used in neonates as a noninvasive estimate of drug levels.

  19. The effect of substrate composition and storage time on urine specific gravity in dogs.

    PubMed

    Steinberg, E; Drobatz, K; Aronson, L

    2009-10-01

    The purpose of this study is to evaluate the effects of substrate composition and storage time on urine specific gravity in dogs. A descriptive cohort study of 15 dogs. The urine specific gravity of free catch urine samples was analysed during a 5-hour time period using three separate storage methods; a closed syringe, a diaper pad and non-absorbable cat litter. The urine specific gravity increased over time in all three substrates. The syringe sample had the least change from baseline and the diaper sample had the greatest change from baseline. The urine specific gravity for the litter and diaper samples had a statistically significant increase from the 1-hour to the 5-hour time point. The urine specific gravity from canine urine stored either on a diaper or in a non-absorbable litter increased over time. Although the change was found to be statistically significant over the 5-hour study period it is unlikely to be clinically significant.

  20. Immunoelectrophoresis - urine

    MedlinePlus

    Immunoglobulin electrophoresis - urine; Gamma globulin electrophoresis - urine; Urine immunoglobulin electrophoresis; IEP - urine ... A clean-catch urine sample is needed. The clean-catch method is used to prevent germs from the penis or vagina from getting ...

  1. Raman spectroscopy applied to identify metabolites in urine of physically active subjects.

    PubMed

    Moreira, Letícia Parada; Silveira, Landulfo; da Silva, Alexandre Galvão; Fernandes, Adriana Barrinha; Pacheco, Marcos Tadeu Tavares; Rocco, Débora Dias Ferraretto Moura

    2017-11-01

    Raman spectroscopy is a rapid and non-destructive technique suitable for biological fluids analysis. In this work, dispersive Raman spectroscopy has been employed as a rapid and nondestructive technique to detect the metabolites in urine of physically active subjects before and after vigorous 30min pedaling or running compared to sedentary subjects. For so, urine samples from 9 subjects were obtained before and immediately after physical activities and submitted to Raman spectroscopy (830nm excitation, 250mW laser power, 20s integration time) and compared to urine from 5 sedentary subjects. The Raman spectra of urine from sedentary showed peaks related to urea, creatinine, ketone bodies, phosphate and other nitrogenous compounds. These metabolic biomarkers presented peaks with different intensities in the urine of physically active individuals after exercises compared to before, measured by the intensity of selected peaks the Raman spectra, which means different concentrations after training. These peaks presented different intensity values for each subject before physical activity, also behaving differently compared to the post-training: some subjects presented increase while others decrease the intensity. Raman spectroscopy may allow the development of a rapid and non-destructive test for metabolic evaluation of the physical training in active and trained subjects using urine samples, allowing nutrition adjustment with the sport's performance. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Reference intervals for 24 laboratory parameters determined in 24-hour urine collections.

    PubMed

    Curcio, Raffaele; Stettler, Helen; Suter, Paolo M; Aksözen, Jasmin Barman; Saleh, Lanja; Spanaus, Katharina; Bochud, Murielle; Minder, Elisabeth; von Eckardstein, Arnold

    2016-01-01

    Reference intervals for many laboratory parameters determined in 24-h urine collections are either not publicly available or based on small numbers, not sex specific or not from a representative sample. Osmolality and concentrations or enzymatic activities of sodium, potassium, chloride, glucose, creatinine, citrate, cortisol, pancreatic α-amylase, total protein, albumin, transferrin, immunoglobulin G, α1-microglobulin, α2-macroglobulin, as well as porphyrins and their precursors (δ-aminolevulinic acid and porphobilinogen) were determined in 241 24-h urine samples of a population-based cohort of asymptomatic adults (121 men and 120 women). For 16 of these 24 parameters creatinine-normalized ratios were calculated based on 24-h urine creatinine. The reference intervals for these parameters were calculated according to the CLSI C28-A3 statistical guidelines. By contrast to most published reference intervals, which do not stratify for sex, reference intervals of 12 of 24 laboratory parameters in 24-h urine collections and of eight of 16 parameters as creatinine-normalized ratios differed significantly between men and women. For six parameters calculated as 24-h urine excretion and four parameters calculated as creatinine-normalized ratios no reference intervals had been published before. For some parameters we found significant and relevant deviations from previously reported reference intervals, most notably for 24-h urine cortisol in women. Ten 24-h urine parameters showed weak or moderate sex-specific correlations with age. By applying up-to-date analytical methods and clinical chemistry analyzers to 24-h urine collections from a large population-based cohort we provide as yet the most comprehensive set of sex-specific reference intervals calculated according to CLSI guidelines for parameters determined in 24-h urine collections.

  3. A Prospective Blinded Evaluation of Urine-DNA Testing for Detection of Urothelial Bladder Carcinoma in Patients with Gross Hematuria.

    PubMed

    Dahmcke, Christina M; Steven, Kenneth E; Larsen, Louise K; Poulsen, Asger L; Abdul-Al, Ahmad; Dahl, Christina; Guldberg, Per

    2016-12-01

    Retrospective studies have provided proof of principle that bladder cancer can be detected by testing for the presence of tumor DNA in urine. We have conducted a prospective blinded study to determine whether a urine-based DNA test can replace flexible cystoscopy in the initial assessment of gross hematuria. A total of 475 consecutive patients underwent standard urological examination including flexible cystoscopy and computed tomography urography, and provided urine samples immediately before (n=461) and after (n=444) cystoscopy. Urine cells were collected using a filtration device and tested for eight DNA mutation and methylation biomarkers. Clinical evaluation identified 99 (20.8%) patients with urothelial bladder tumors. With this result as a reference and based on the analysis of all urine samples, the DNA test had a sensitivity of 97.0%, a specificity of 76.9%, a positive predictive value of 52.5%, and a negative predictive value of 99.0%. In three patients with a positive urine-DNA test without clinical evidence of cancer, a tumor was detected at repeat cystoscopy within 16 mo. Our results suggest that urine-DNA testing can be used to identify a large subgroup of patients with gross hematuria in whom cystoscopy is not required. We tested the possibility of using a urine-based DNA test to check for bladder cancer in patients with visible blood in the urine. Our results show that the test efficiently detects bladder cancer and therefore may be used to greatly reduce the number of patients who would need to undergo cystoscopy. Copyright © 2016 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  4. Consideration of the degree of increase in urine metadrenalines provides superior specificity in the diagnosis of phaeochromocytoma than additional urine catecholamine measurement.

    PubMed

    Scargill, J J; Reed, P; Kane, J

    2013-01-01

    Measurement of fractionated plasma or urine metadrenalines is the recommended screening test in the diagnosis of phaeochromocytoma, with clinical cut-offs geared towards diagnostic sensitivity. Current practice at Salford Royal Hospital is to add urine catecholamines onto samples with raised urine metadrenalines, with the aim of adding specificity to a diagnosis of phaeochromocytoma. This practice was reviewed by identifying a series of patients with raised urine metadrenalines who had catecholamines reflectively added. A total of 358 samples were identified from 242 patients, of which 228 had urine catecholamines measured. A diagnosis of 'phaeochromocytoma' (n = 41) or 'no phaeochromocytoma' (n = 90) was obtained in 131 of 228 patients, giving raised urine metadrenalines a positive predictive value for phaeochromocytoma of 31%. The finding of increased urine catecholamines in samples with raised urine metadrenalines increased specificity for phaeochromocytoma to 70%. However, 95% diagnostic specificity for phaeochromocytoma could be achieved by the introduction of a second cut-off for urine metadrenalines geared towards maximizing specificity. Consideration of the degree of increase in urine metadrenalines is a superior method of determining the likelihood of phaeochromocytoma than measurement of urine catecholamines.

  5. Cocaine and opiates use in pregnancy: detection of drugs in neonatal meconium and urine.

    PubMed

    López, P; Bermejo, A M; Tabernero, M J; Cabarcos, P; Alvarez, I; Fernández, P

    2009-09-01

    In this study, the case of a newborn with symptoms of hyperexcitability was analyzed. After it was confirmed in the hospital that the mother had consumed drugs during pregnancy using an enzyme multiplied immunoassay technique, samples of the newborn's urine and meconium were sent to our laboratory to observe the evolution in the distribution of cocaine and opiates during the days following birth. For urine analysis, screening was done with an immunoassay technique, and the confirmation was done by gas chromatography-mass spectrometry (GC-MS) according to a published method. A GC-MS method for simultaneous analysis of cocaine, benzoylecgonine, codeine, morphine, and 6-acetylmorphine in meconium is described. GC-MS confirmation of urine and meconium results showed consumption of cocaine and codeine during pregnancy and also showed the levels of drugs gradually declined, totally disappearing by the third day.

  6. Latent Virus Reactivation in Space Shuttle Astronauts

    NASA Technical Reports Server (NTRS)

    Mehta, S. K.; Crucian, B. E.; Stowe, R. P.; Sams, C.; Castro, V. A.; Pierson, D. L.

    2011-01-01

    Latent virus reactivation was measured in 17 astronauts (16 male and 1 female) before, during, and after short-duration Space Shuttle missions. Blood, urine, and saliva samples were collected 2-4 months before launch, 10 days before launch (L-10), 2-3 hours after landing (R+0), 3 days after landing (R+14), and 120 days after landing (R+120). Epstein-Barr virus (EBV) DNA was measured in these samples by quantitative polymerase chain reaction. Varicella-zoster virus (VZV) DNA was measured in the 381 saliva samples and cytomegalovirus (CMV) DNA in the 66 urine samples collected from these subjects. Fourteen astronauts shed EBV DNA in 21% of their saliva samples before, during, and after flight, and 7 astronauts shed VZV in 7.4% of their samples during and after flight. It was interesting that shedding of both EBV and VZV increased during the flight phase relative to before or after flight. In the case of CMV, 32% of urine samples from 8 subjects contained DNA of this virus. In normal healthy control subjects, EBV shedding was found in 3% and VZV and CMV were found in less than 1% of the samples. The circadian rhythm of salivary cortisol measured before, during, and after space flight did not show any significant difference between flight phases. These data show that increased reactivation of latent herpes viruses may be associated with decreased immune system function, which has been reported in earlier studies as well as in these same subjects (data not reported here).

  7. Importance of sample preparation for molecular diagnosis of lyme borreliosis from urine.

    PubMed

    Bergmann, A R; Schmidt, B L; Derler, A-M; Aberer, E

    2002-12-01

    Urine PCR has been used for the diagnosis of Borrelia burgdorferi infection in recent years but has been abandoned because of its low sensitivity and the irreproducibility of the results. Our study aimed to analyze technical details related to sample preparation and detection methods. Crucial for a successful urine PCR were (i) avoidance of the first morning urine sample; (ii) centrifugation at 36,000 x g; and (iii) the extraction method, with only DNAzol of the seven different extraction methods used yielding positive results with patient urine specimens. Furthermore, storage of frozen urine samples at -80 degrees C reduced the sensitivity of a positive urine PCR result obtained with samples from 72 untreated erythema migrans (EM) patients from 85% in the first 3 months to <30% after more than 3 months. Bands were detected at 276 bp on ethidium bromide-stained agarose gels after amplification by a nested PCR. The specificity of bands for 32 of 33 samples was proven by hybridization with a GEN-ETI-K-DEIA kit and for a 10 further positive amplicons by sequencing. By using all of these steps to optimize the urine PCR technique, B. burgdorferi infection could be diagnosed by using urine samples from EM patients with a sensitivity (85%) substantially better than that of serological methods (50%). This improved method could be of future importance as an additional laboratory technique for the diagnosis of unclear, unrecognized borrelia infections and diseases possibly related to Lyme borreliosis.

  8. Identifying Urinary and Serum Exosome Biomarkers for Radiation Exposure Using a Data Dependent Acquisition and SWATH-MS Combined Workflow.

    PubMed

    Kulkarni, Shilpa; Koller, Antonius; Mani, Kartik M; Wen, Ruofeng; Alfieri, Alan; Saha, Subhrajit; Wang, Jian; Patel, Purvi; Bandeira, Nuno; Guha, Chandan; Chen, Emily I

    2016-11-01

    Early and accurate assessment of radiation injury by radiation-responsive biomarkers is critical for triage and early intervention. Biofluids such as urine and serum are convenient for such analysis. Recent research has also suggested that exosomes are a reliable source of biomarkers in disease progression. In the present study, we analyzed total urine proteome and exosomes isolated from urine or serum for potential biomarkers of acute and persistent radiation injury in mice exposed to lethal whole body irradiation (WBI). For feasibility studies, the mice were irradiated at 10.4 Gy WBI, and urine and serum samples were collected 24 and 72 hours after irradiation. Exosomes were isolated and analyzed using liquid chromatography mass spectrometry/mass spectrometry-based workflow for radiation exposure signatures. A data dependent acquisition and SWATH-MS combined workflow approach was used to identify significantly exosome biomarkers indicative of acute or persistent radiation-induced responses. For the validation studies, mice were exposed to 3, 6, 8, or 10 Gy WBI, and samples were analyzed for comparison. A comparison between total urine proteomics and urine exosome proteomics demonstrated that exosome proteomic analysis was superior in identifying radiation signatures. Feasibility studies identified 23 biomarkers from urine and 24 biomarkers from serum exosomes after WBI. Urinary exosome signatures identified different physiological parameters than the ones obtained in serum exosomes. Exosome signatures from urine indicated injury to the liver, gastrointestinal, and genitourinary tracts. In contrast, serum showed vascular injuries and acute inflammation in response to radiation. Selected urinary exosomal biomarkers also showed changes at lower radiation doses in validation studies. Exosome proteomics revealed radiation- and time-dependent protein signatures after WBI. A total of 47 differentially secreted proteins were identified in urinary and serum exosomes. Together, these data showed the feasibility of defining biomarkers that could elucidate tissue-associated and systemic response caused by high-dose ionizing radiation. This is the first report using an exosome proteomics approach to identify radiation signatures. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Identifying Urinary and Serum Exosome Biomarkers for Radiation Exposure Using a Data Dependent Acquisition and SWATH-MS Combined Workflow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kulkarni, Shilpa; Koller, Antonius; Proteomics Shared Resource, Herbert Irving Comprehensive Cancer Center, New York, New York

    Purpose: Early and accurate assessment of radiation injury by radiation-responsive biomarkers is critical for triage and early intervention. Biofluids such as urine and serum are convenient for such analysis. Recent research has also suggested that exosomes are a reliable source of biomarkers in disease progression. In the present study, we analyzed total urine proteome and exosomes isolated from urine or serum for potential biomarkers of acute and persistent radiation injury in mice exposed to lethal whole body irradiation (WBI). Methods and Materials: For feasibility studies, the mice were irradiated at 10.4 Gy WBI, and urine and serum samples were collected 24more » and 72 hours after irradiation. Exosomes were isolated and analyzed using liquid chromatography mass spectrometry/mass spectrometry-based workflow for radiation exposure signatures. A data dependent acquisition and SWATH-MS combined workflow approach was used to identify significantly exosome biomarkers indicative of acute or persistent radiation-induced responses. For the validation studies, mice were exposed to 3, 6, 8, or 10 Gy WBI, and samples were analyzed for comparison. Results: A comparison between total urine proteomics and urine exosome proteomics demonstrated that exosome proteomic analysis was superior in identifying radiation signatures. Feasibility studies identified 23 biomarkers from urine and 24 biomarkers from serum exosomes after WBI. Urinary exosome signatures identified different physiological parameters than the ones obtained in serum exosomes. Exosome signatures from urine indicated injury to the liver, gastrointestinal, and genitourinary tracts. In contrast, serum showed vascular injuries and acute inflammation in response to radiation. Selected urinary exosomal biomarkers also showed changes at lower radiation doses in validation studies. Conclusions: Exosome proteomics revealed radiation- and time-dependent protein signatures after WBI. A total of 47 differentially secreted proteins were identified in urinary and serum exosomes. Together, these data showed the feasibility of defining biomarkers that could elucidate tissue-associated and systemic response caused by high-dose ionizing radiation. This is the first report using an exosome proteomics approach to identify radiation signatures.« less

  10. Immunodetection and molecular determination of visceral and cutaneous Leishmania infection using patients' urine.

    PubMed

    Mirzaei, Asad; Ahmadipour, Fereshteh; Cannet, Arnaud; Marty, Pierre; Delaunay, Pascal; Perrin, Pascale; Dorkeld, Franck; Sereno, Denis; Akhoundi, Mohammad

    2018-05-27

    The diagnosis of leishmaniasis relies mainly on the use of invasive processes, to collect the biological material for detecting Leishmania parasites. Body fluids, which can be collected by non-invasive process, would greatly facilitate the leishmaniasis diagnosis. In the present study, we investigated the potency of urine immunoblotting to diagnose cutaneous and visceral leishmaniasis and we compared with routine molecular methods. A total of 80 samples, including 40 sera and their 40 corresponding urine samples were collected from 37 suspected patients with cutaneous and visceral leishmaniasis, and 3 healthy individuals (as control), in Ilam and Ardabil provinces of Iran. All sera and urine samples were analyzed, using immunoblotting. The confirmation of leishmaniasis infection was performed, using conventional and quantitative PCRs as well as by sequencing the amplicons. Among 37 suspected patients, 23 patients presented cutaneous lesions (CL) and 14 exhibited clinical symptoms reminiscent of visceral leishmaniasis (L. infantum). Among cutaneous patients, 15 were positive for zoonotic cutaneous leishmaniasis (L. major), and eight for anthroponotic cutaneous leishmaniasis (L. tropica). Molecular quantification of Leishmania parasites was performed on sera, urines and cutaneous biopsies of CL and VL patients, demonstrating that parasite load is lower in urines, compared to sera or biopsy. DNA can be detected in 20 out of 23 (86.9%) CL urine samples and in 13 out of 14 (92.8%) VL urine samples. Immunodetection analysis demonstrates that 22 out of 23 (95.6%) sera from CL patients and all patients suspected with VL are positive. For urine samples, 18 out of 23 (78.2%) urine of CL patients and 13 out of 14 (92.8%) urine of VL patients were positive, using Western blot. Therefore, immunodetection and molecular analysis using urine samples can be used as a diagnostic tool for surveying cutaneous and visceral leishmaniasis. Copyright © 2017. Published by Elsevier B.V.

  11. HCG in urine

    MedlinePlus

    Beta-HCG - urine; Human chorionic gonadotropin - urine; Pregnancy test - hCG in urine ... To collect a urine sample, you urinate into a special (sterile) cup. Home pregnancy tests require the test strip to be dipped into ...

  12. DNA methylation profiling of genomic DNA isolated from urine in diabetic chronic kidney disease: A pilot study

    PubMed Central

    Sexton-Oates, Alexandra; Carmody, Jake; Ekinci, Elif I.; Dwyer, Karen M.; Saffery, Richard

    2018-01-01

    Aim To characterise the genomic DNA (gDNA) yield from urine and quality of derived methylation data generated from the widely used Illuminia Infinium MethylationEPIC (HM850K) platform and compare this with buffy coat samples. Background DNA methylation is the most widely studied epigenetic mark and variations in DNA methylation profile have been implicated in diabetes which affects approximately 415 million people worldwide. Methods QIAamp Viral RNA Mini Kit and QIAamp DNA micro kit were used to extract DNA from frozen and fresh urine samples as well as increasing volumes of fresh urine. Matched buffy coats to the frozen urine were also obtained and DNA was extracted from the buffy coats using the QIAamp DNA Mini Kit. Genomic DNA of greater concentration than 20μg/ml were used for methylation analysis using the HM850K array. Results Irrespective of extraction technique or the use of fresh versus frozen urine samples, limited genomic DNA was obtained using a starting sample volume of 5ml (0–0.86μg/mL). In order to optimize the yield, we increased starting volumes to 50ml fresh urine, which yielded only 0–9.66μg/mL A different kit, QIAamp DNA Micro Kit, was trialled in six fresh urine samples and ten frozen urine samples with inadequate DNA yields from 0–17.7μg/mL and 0–1.6μg/mL respectively. Sufficient genomic DNA was obtained from only 4 of the initial 41 frozen urine samples (10%) for DNA methylation profiling. In comparison, all four buffy coat samples (100%) provided sufficient genomic DNA. Conclusion High quality data can be obtained provided a sufficient yield of genomic DNA is isolated. Despite optimizing various extraction methodologies, the modest amount of genomic DNA derived from urine, may limit the generalisability of this approach for the identification of DNA methylation biomarkers of chronic diabetic kidney disease. PMID:29462136

  13. DNA methylation profiling of genomic DNA isolated from urine in diabetic chronic kidney disease: A pilot study.

    PubMed

    Lecamwasam, Ashani; Sexton-Oates, Alexandra; Carmody, Jake; Ekinci, Elif I; Dwyer, Karen M; Saffery, Richard

    2018-01-01

    To characterise the genomic DNA (gDNA) yield from urine and quality of derived methylation data generated from the widely used Illuminia Infinium MethylationEPIC (HM850K) platform and compare this with buffy coat samples. DNA methylation is the most widely studied epigenetic mark and variations in DNA methylation profile have been implicated in diabetes which affects approximately 415 million people worldwide. QIAamp Viral RNA Mini Kit and QIAamp DNA micro kit were used to extract DNA from frozen and fresh urine samples as well as increasing volumes of fresh urine. Matched buffy coats to the frozen urine were also obtained and DNA was extracted from the buffy coats using the QIAamp DNA Mini Kit. Genomic DNA of greater concentration than 20μg/ml were used for methylation analysis using the HM850K array. Irrespective of extraction technique or the use of fresh versus frozen urine samples, limited genomic DNA was obtained using a starting sample volume of 5ml (0-0.86μg/mL). In order to optimize the yield, we increased starting volumes to 50ml fresh urine, which yielded only 0-9.66μg/mL A different kit, QIAamp DNA Micro Kit, was trialled in six fresh urine samples and ten frozen urine samples with inadequate DNA yields from 0-17.7μg/mL and 0-1.6μg/mL respectively. Sufficient genomic DNA was obtained from only 4 of the initial 41 frozen urine samples (10%) for DNA methylation profiling. In comparison, all four buffy coat samples (100%) provided sufficient genomic DNA. High quality data can be obtained provided a sufficient yield of genomic DNA is isolated. Despite optimizing various extraction methodologies, the modest amount of genomic DNA derived from urine, may limit the generalisability of this approach for the identification of DNA methylation biomarkers of chronic diabetic kidney disease.

  14. Trace Chemical Analysis Methodology

    DTIC Science & Technology

    1980-04-01

    oxidation of nitrite-containing species. Calibration studies were then made in preparation for the analysis of unknown samples of nitrate in urine and...the procedure for nitrate determination was made on two types of samples : human urine , and drinking water from a city water supply. Five samples of...AND URINE Concentration Standard Sample type of NO3, ppm deviation Drinking water 1.29 ±0 04 1.20 ±0.09 1.29 ±0.14 1.15 ±0.08 0.88 ±0.07 Human urine

  15. Size-exclusion chromatography-based enrichment of extracellular vesicles from urine samples

    PubMed Central

    Lozano-Ramos, Inés; Bancu, Ioana; Oliveira-Tercero, Anna; Armengol, María Pilar; Menezes-Neto, Armando; Del Portillo, Hernando A.; Lauzurica-Valdemoros, Ricardo; Borràs, Francesc E.

    2015-01-01

    Renal biopsy is the gold-standard procedure to diagnose most of renal pathologies. However, this invasive method is of limited repeatability and often describes an irreversible renal damage. Urine is an easily accessible fluid and urinary extracellular vesicles (EVs) may be ideal to describe new biomarkers associated with renal pathologies. Several methods to enrich EVs have been described. Most of them contain a mixture of proteins, lipoproteins and cell debris that may be masking relevant biomarkers. Here, we evaluated size-exclusion chromatography (SEC) as a suitable method to isolate urinary EVs. Following a conventional centrifugation to eliminate cell debris and apoptotic bodies, urine samples were concentrated using ultrafiltration and loaded on a SEC column. Collected fractions were analysed by protein content and flow cytometry to determine the presence of tetraspanin markers (CD63 and CD9). The highest tetraspanin content was routinely detected in fractions well before the bulk of proteins eluted. These tetraspanin-peak fractions were analysed by cryo-electron microscopy (cryo-EM) and nanoparticle tracking analysis revealing the presence of EVs. When analysed by sodium dodecyl sulphate–polyacrylamide gel electrophoresis, tetraspanin-peak fractions from urine concentrated samples contained multiple bands but the main urine proteins (such as Tamm–Horsfall protein) were absent. Furthermore, a preliminary proteomic study of these fractions revealed the presence of EV-related proteins, suggesting their enrichment in concentrated samples. In addition, RNA profiling also showed the presence of vesicular small RNA species. To summarize, our results demonstrated that concentrated urine followed by SEC is a suitable option to isolate EVs with low presence of soluble contaminants. This methodology could permit more accurate analyses of EV-related biomarkers when further characterized by -omics technologies compared with other approaches. PMID:26025625

  16. Interlaboratory and between-specimen comparisons of diagnostic tests for leptospirosis in sheep and cattle.

    PubMed

    Fang, Fang; Collins-Emerson, Julie M; Heuer, Cord; Hill, Fraser I; Tisdall, David J; Wilson, Peter R; Benschop, Jackie

    2014-11-01

    A study was performed to investigate interlaboratory test agreement between a research and a commercial veterinary diagnostic laboratory on blood and urine samples, and to investigate test agreement between blood, urine, and kidney samples (research laboratory) for leptospirosis diagnosis. Samples were sourced from 399 sheep and 146 beef cattle from a local abattoir. Interlaboratory agreement for real-time quantitative polymerase chain reaction (qPCR) results on urine samples was almost perfect (kappa = 0.90), despite the use of different amplification targets (DNA gyrase subunit B gene vs. 16s ribosomal RNA gene), chemistries (SYTO9 vs. TaqMan probe), and pre-PCR processing. Interlaboratory agreement for microscopic agglutination test (MAT) positivity was almost perfect (kappa = 0.93) for Leptospira borgpetersenii serovar Hardjo subtype Hardjobovis (Hardjobovis) but moderate (kappa = 0.53) for Leptospira interrogans serovar Pomona (Pomona). Among animals that had different titers recorded, higher Hardjobovis and lower Pomona titers were reported by the commercial laboratory than by the research laboratory (P < 0.005). These interlaboratory comparisons can assist researchers and diagnosticians in interpreting the sometimes discrepant test results. Within the research laboratory, the comparison of qPCR results on urine and kidney showed almost perfect agreement (kappa = 0.84), suggesting that the qPCR on these 2 specimens can be used interchangeably. The agreement between MAT positivity and urine and kidney qPCR results was fair (kappa = 0.32 and kappa = 0.33, respectively). However, the prevalence ratio of urine and kidney qPCR positivity in Hardjobovis-seropositive versus Hardjobovis-seronegative sheep indicated that Hardjobovis seropositivity found in sheep may be able to predict shedding or renal carriage. © 2014 The Author(s).

  17. Quantification of vosaroxin and its metabolites N-desmethylvosaroxin and O-desmethylvosaroxin in human plasma and urine using high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Nijenhuis, C M; Lucas, L; Rosing, H; Jamieson, G; Fox, J A; Schellens, J H M; Beijnen, J H

    2016-08-01

    Vosaroxin is a first-in-class anticancer quinolone derivative topoisomerase II inhibitor that is currently in development in combination with cytarabine for the treatment of acute myeloid leukemia (AML). To investigate vosaroxin pharmacokinetics (PK) in patients, liquid chromatography tandem mass spectrometry (LC-MS/MS) assays to quantify vosaroxin and the two metabolites N-desmethylvosaroxin and O-desmethylvosaroxin in human plasma and urine were developed and validated. Immediately after collection the samples were stored at -80°C. Prior to analysis, the plasma samples were subjected to protein precipitation and the urine samples were diluted. For both assays the reconstituted extracts were injected on a Symmetry Shield RP8 column and gradient elution was applied using 0.1% formic acid in water and acetonitrile-methanol (50:50, v/v). Analyses were performed with a triple quadruple mass spectrometer in positive-ion mode. A deuterated isotope of vosaroxin was used as internal standard for the quantification. The validated assays quantify vosaroxin and N-desmethylvosaroxin in the concentration range of 2-500ng/mL in plasma and urine. For O-desmethylvosaroxin the concentration range of 4-500ng/mL in plasma and urine was validated. Dilution integrity experiments show that samples can be diluted 25 fold in control matrix prior to analysis. The expanded concentration range for plasma and urine for vosaroxin and N-desmethylvosaroxin is therefore from 2 to 15,000ng/mL and in plasma for O-desmethylvosaroxin from 4 to 15,000ng/mL. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Potential antiproliferative activity of polyphenol metabolites against human breast cancer cells and their urine excretion pattern in healthy subjects following acute intake of a polyphenol-rich juice of grumixama (Eugenia brasiliensis Lam.).

    PubMed

    Teixeira, L L; Costa, G R; Dörr, F A; Ong, T P; Pinto, E; Lajolo, F M; Hassimotto, N M A

    2017-06-21

    The bioavailability and metabolism of anthocyanins and ellagitannins following acute intake of grumixama fruit, native Brazilian cherry, by humans, and its in vitro antiproliferative activity against breast cancer cells (MDA-MB-231) were investigated. A single dose of grumixama juice was administered to healthy women (n = 10) and polyphenol metabolites were analyzed in urine and plasma samples collected over 24 h. The majority of the metabolites circulating and excreted in urine were phenolic acids and urolithin conjugates, the gut microbiota catabolites of both classes of polyphenols, respectively. According to pharmacokinetic parameters, the subjects were divided into two distinct groups, high and low urinary metabolite excretors. The pool of polyphenol metabolites found in urine samples showed a significant inhibition of cell proliferation and G2/M cell cycle arrest in MDA-MB-231 cells. Our findings demonstrate the large interindividual variability concerning the polyphenol metabolism, which possibly could reflect in health promotion.

  19. [Mercury and creatinine in urine of employees exposed to magnetic fields. A study of a group electrolysis-operators in Norzink A/S in Odda].

    PubMed

    Schmidt, F; Mannsåker

    1997-01-20

    The results described are based on a study of 26 male cell house employees. They were exposed to a combination of static magnetic fields (3-10 mT) and low frequency oscillating magnetic fields of variable frequency and strength for eight hours a day over a period of four weeks. Every fifth week was spent off work. Urine samples collected at the end of the four weeks of exposure were compared with samples collected at the end of the week off work. The results show that the cell house workers excreted significantly more mercury in their urine after exposure to magnetic fields (p = 0.01). The mercury/creatinine ratio was also significantly higher after exposure (p < 0.01). These results support findings by Schmidt in a study from 1992 when the levels of mercury and creatinine in the urine of cell house workers were compared with the levels in office personnel.

  20. Effects of processing delay, temperature, and transport tube type on results of quantitative bacterial culture of canine urine.

    PubMed

    Patterson, Carly A; Bishop, Micah A; Pack, Julie D; Cook, Audrey K; Lawhon, Sara D

    2016-01-15

    To determine the impact of processing delay, temperature, and transport tube type on results of quantitative bacterial culture (QBC) of canine urine. Diagnostic test evaluation. 60 mL of pooled urine from 4 dogs, divided into six 10-mL aliquots. Urine aliquots were spiked with bacteria from 1 of 6 independent Escherichia coli cultures to achieve a target bacterial concentration of 10(5) CFUs/mL. One milliliter from each aliquot was transferred into 5 silicone-coated clot tubes (SCTs) and 5 urine transport tubes (UTTs). Samples were stored at 4°C (39°F) and 25°C (77°F) for 0, 8, and 24 hours, and then standard QBCs were performed. Median bacterial concentration for urine samples stored in a UTT for 24 hours at 4°C was lower than that for samples stored in an SCT under the same conditions. Conversely, a substantial decrease in median bacterial concentration was identified for samples stored for 24 hours in an SCT at 25°C, compared with the median concentration for samples stored in a UTT under the same conditions. Median bacterial concentration in samples stored in an SCT at 25°C for 24 hours (275 CFUs/mL) was less than the cutoff typically used to define clinically important bacteriuria by use of urine samples obtained via cystocentesis (ie, > 1,000 CFUs/mL). Canine urine samples submitted for immediate QBC should be transported in plain sterile tubes such as SCTs. When prolonged (24-hour) storage at room temperature is anticipated, urine samples should be transported in UTTs.

  1. Relationship between conventional culture and flow cytometry for the diagnosis of urinary tract infection.

    PubMed

    García-Coca, Marta; Gadea, Ignacio; Esteban, Jaime

    2017-06-01

    Urine culture is the gold standard for the diagnosis of urinary tract infections (UTI). The use of flow cytometry analyzers (FCA) prior to culture allows for the quantification and recognition of cell components in urine to be automated and makes it possible to relate these data to the urine pathogens subsequently identified in cultures. Urine samples were assessed with the Sysmex UF-1000i analyzer. Those that met the criteria for culture (> 25 leukocytes/μL or > 385 bacteria/μL) were subjected to quantitative urine culture on chromogenic agar. Counts of red blood cells (RBC), white blood cells (WBC), epithelial cells (EC), and the kind of microorganisms identified in cultures were evaluated. A total of 17,483 samples were processed by FCA. Of these, 9057 met the criteria for culture. Urine cultures were reduced by 48.2%. The most common urine pathogen was Escherichia coli (60.3%). Negative urine cultures were significantly (p < 0.001) associated with a lower WBC count than urine with E. coli, Klebsiella spp. and Proteus spp., but urine with Enterococcus spp. had a lower WBC than negative urine. Contaminated urine had a significantly (p < 0.001) lower WBC than urine with E. coli, Klebsiella spp. and Proteus spp., but no differences were found for Enterococcus spp. (p = 0.729). Negative urine cultures had significantly (p < 0.05) higher EC than all positive urine samples. Contaminated urine was associated (p < 0.001) with higher EC than cultures with E. coli and Klebsiella spp., in comparison with cultures with Enterococcus spp. (p = 0.091) and Proteus spp. (p = 0.251). The use of the Sysmex UF-1000i flow cytometer for screening urine samples allows for a reduction in the number of urine cultures. WBC values correlate well with the main urine pathogens related to UTI. The results observed for Enterococcus spp. suggest a low impact of these pathogens as a cause of UTI.

  2. A Randomized Trial of Employment-Based Reinforcement of Cocaine Abstinence in Injection Drug Users

    PubMed Central

    Silverman, Kenneth; Wong, Conrad J; Needham, Mick; Diemer, Karly N; Knealing, Todd; Crone-Todd, Darlene; Fingerhood, Michael; Nuzzo, Paul; Kolodner, Kenneth

    2007-01-01

    High-magnitude and long-duration abstinence reinforcement can promote drug abstinence but can be difficult to finance. Employment may be a vehicle for arranging high-magnitude and long-duration abstinence reinforcement. This study determined if employment-based abstinence reinforcement could increase cocaine abstinence in adults who inject drugs and use cocaine during methadone treatment. Participants could work 4 hr every weekday in a workplace where they could earn about $10.00 per hour in vouchers; they were required to provide routine urine samples. Participants who attended the workplace and provided cocaine-positive urine samples during the initial 4 weeks were invited to work 26 weeks and were randomly assigned to an abstinence-and-work (n  =  28) or work-only (n  =  28) group. Abstinence-and-work participants had to provide urine samples showing cocaine abstinence to work and maintain maximum pay. Work-only participants could work independent of their urinalysis results. Abstinence-and-work participants provided more (p  =  .004; OR  =  5.80, 95% CI  =  2.03–16.56) cocaine-negative urine samples (29%) than did work-only participants (10%). Employment-based abstinence reinforcement can increase cocaine abstinence. PMID:17970256

  3. A Capacitive Touch Screen Sensor for Detection of Urinary Tract Infections in Portable Biomedical Devices

    PubMed Central

    Honrado, Carlos; Dong, Tao

    2014-01-01

    Incidence of urinary tract infections (UTIs) is the second highest among all infections; thus, there is a high demand for bacteriuria detection. Escherichia coli are the main cause of UTIs, with microscopy methods and urine culture being the detection standard of these bacteria. However, the urine sampling and analysis required for these methods can be both time-consuming and complex. This work proposes a capacitive touch screen sensor (CTSS) concept as feasible alternative for a portable UTI detection device. Finite element method (FEM) simulations were conducted with a CTSS model. An exponential response of the model to increasing amounts of E. coli and liquid samples was observed. A measurable capacitance change due to E. coli presence and a tangible difference in the response given to urine and water samples were also detected. Preliminary experimental studies were also conducted on a commercial CTSS using liquid solutions with increasing amounts of dissolved ions. The CTSS was capable of distinguishing different volumes of liquids, also giving an exponential response. Furthermore, the CTSS gave higher responses to solutions with a superior amount of ions. Urine samples gave the top response among tested liquids. Thus, the CTSS showed the capability to differentiate solutions by their ionic content. PMID:25196109

  4. Animal urine as painting materials in African rock art revealed by cluster ToF-SIMS mass spectrometry imaging.

    PubMed

    Mazel, Vincent; Richardin, Pascale; Touboul, David; Brunelle, Alain; Richard, Caroline; Laval, Eric; Walter, Philippe; Laprévote, Olivier

    2010-08-01

    The rock art site at the village of Songo in Mali is a very important Dogon ritual place where, since the end of the nineteenth century until today, takes place the ceremony of circumcision. During these ceremonies, paintings are performed on the walls of the shelter with mainly three colors: red, black and white. Ethnological literature mentions the use of animal urine of different species such as birds, lizards or snakes as a white pigment. Urine of these animals is mainly composed of uric acid or urate salts. In this article, time-of-flight secondary ion mass spectrometry (ToF-SIMS) is used to compare uric acid, snake urine and a sample of a white pigment of a Dogon painting coming from the rock art site of Songo. ToF-SIMS measurements in both positive and negative ion modes on reference compounds and snake urine proved useful for the study of uric acid and urate salts. This method enables to identify unambiguously these compounds owing to the detection in negative ion mode of the ion corresponding to the deprotonated molecule ([M-H](-) at m/z 167.01) and its fragment ions. Moreover, the mass spectra obtained in positive ion mode permit to differentiate uric acid and urate salts on the basis of specific ions. Applying this method to the Dogon white pigments sample, we show that the sample is entirely composed of uric acid. This proves for the first time, that animal urine was used as a pigment by the Dogon. The presence of uric acid instead of urate salts as normally expected in animal urine could be explained by the preparation of the pigment for its application on the stone. Copyright 2010 John Wiley & Sons, Ltd.

  5. Absence of bacterial DNA in culture-negative urine from cats with and without lower urinary tract disease.

    PubMed

    Lund, Heidi Sjetne; Skogtun, Gaute; Sørum, Henning; Eggertsdóttir, Anna Vigdís

    2015-10-01

    A diagnosis of bacterial cystitis commonly relies on a positive microbiological culture demonstrating the presence of a significant number of colony-forming units/ml urine, as urine within the upper urinary tract, bladder and proximal urethra generally is considered sterile. Recent studies from human and veterinary medicine indicate the presence of non-culturable bacteria in culture-negative urine samples. The aim of the present study was to determine the occurrence of bacterial DNA in culture-negative urine samples from cats with signs of feline lower urinary tract disease (FLUTD) and healthy control cats by 16S ribosomal DNA PCR and subsequent sequencing. The study sample included 38 culture-negative urine samples from cats with FLUTD and 43 culture-negative samples from control cats. Eight culture-positive urine samples from cats with FLUTD were included as external positive controls in addition to negative reaction controls. Of possible methodological limitations, degradation of DNA due to storage, the use of non-sedimented urine for DNA isolation and lack of internal positive reaction controls should be mentioned. The positive controls were recognised, but occurrence of bacterial DNA in culture-negative urine from cats with or without signs of lower urinary tract disease was not demonstrated. However, considering the possible methodological limitations, the presence of bacterial DNA in the urine of culture-negative FLUTD cats cannot be excluded based on the present results alone. Therefore, a prospective study reducing the possibility of degradation of DNA due to storage, in combination with modifications enhancing the chance of detecting even lower levels of bacterial DNA in culture-negative samples, seems warranted. © ISFM and AAFP 2014.

  6. The Effects of Instrumentation on Urine Cytology and CK-20 Analysis for the Detection of Bladder Cancer.

    PubMed

    Wegelin, Olivier; Bartels, Diny W M; Tromp, Ellen; Kuypers, Karel C; van Melick, Harm H E

    2015-10-01

    To evaluate the effects of cystoscopy on urine cytology and additional cytokeratin-20 (CK-20) staining in patients presenting with gross hematuria. For 83 patients presenting with gross hematuria, spontaneous and instrumented paired urine samples were analyzed. Three patients were excluded. Spontaneous samples were collected within 1 hour before cystoscopy, and the instrumented samples were tapped through the cystoscope. Subsequently, patients underwent cystoscopic evaluation and imaging of the urinary tract. If tumor suspicious lesions were found on cystoscopy or imaging, subjects underwent transurethral resection or ureterorenoscopy. Two blinded uropathological reviewers (DB, KK) evaluated 160 urine samples. Reference standards were results of cystoscopy, imaging, or histopathology. Thirty-seven patients (46.3%) underwent transurethral resection or ureterorenoscopy procedures. In 30 patients (37.5%) tumor presence was confirmed by histopathology. The specificity of urine analysis was significantly higher for spontaneous samples than instrumented samples for both cytology alone (94% vs 72%, P = .01) and for cytology combined with CK-20 analysis (98% vs 84%, P = .02). The difference in sensitivity between spontaneous and instrumented samples was not significant for both cytology alone (40% vs 53%) and combined with CK-20 analysis (67% vs 67%). The addition of CK-20 analysis to cytology significantly increases test sensitivity in spontaneous urine cytology (67% vs 40%, P = .03). Instrumentation significantly decreases specificity of urine cytology. This may lead to unnecessary diagnostic procedures. Additional CK-20 staining in spontaneous urine cytology significantly increases sensitivity but did not improve the already high specificity. We suggest performing urine cytology and CK-20 analysis on spontaneously voided urine. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Ex vivo spontaneous generation of 19-norandrostenedione and nandrolone detected in equine plasma and urine.

    PubMed

    Guan, Fuyu; Uboh, Cornelius E; Soma, Lawrence R; You, Youwen; Li, Xiaoqing; McDonnell, Sue

    2012-01-01

    19-Norandrostenedione (NAED) and nandrolone are anabolic-androgenic steroids (AASs). Nandrolone was regarded solely as a synthetic AAS until the 1980s when trace concentrations of apparently endogenous nandrolone were detected in urine samples obtained from intact male horses (stallions). Since then, its endogenous origin has been reported in boars and bulls; endogenous NAED and nandrolone have been identified in plasma and urine samples collected from stallions. More recently, however, it was suggested that NAED and nandrolone detected in urine samples from stallions are primarily artifacts due to the analytical procedure. The present study was undertaken to determine whether NAED and nandrolone detected in plasma and urine samples collected from stallions are truly endogenous or artifacts from sample processing. To answer this question, fresh plasma and urine samples from ≥8 stallions were analyzed for the two AASs, soon after collection, by liquid chromatography hyphenated to tandem mass spectrometry (LC-MS/MS). NAED and nandrolone were not detected in fresh plasma samples but detected in the same samples post storage. Concentrations of both AASs increased with storage time, and the increases were greater at a higher storage temperature (37°C versus 4°C, and ambient temperature versus 4°C). Although NAED was detected in some fresh stallion urine samples, its concentration (<407 pg/mL) was far lower (<0.4%) than that in the same samples post storage (at ambient temperature for 15 days). Nandrolone was not detected in most of fresh urine samples but detected in the same samples post storage. Based on these results, it is concluded that all NAED and nandrolone detected in stored plasma samples of stallions and most of them in the stored urine samples are not from endogenous origins but spontaneously generated during sample storage, most likely from spontaneous decarboxylation of androstenedione-19-oic acid and testosterone-19-oic acid. To our knowledge, it is the first time that all NAED and nandrolone detected in plasma of stallions and most of them detected in the urine have been shown to be spontaneously generated in vitro during sample storage. This finding would have significant implications with regard to the regulation of the two steroids in horse racing. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. Calcium - urine

    MedlinePlus

    Urinary Ca+2; Kidney stones - calcium in urine; Renal calculi - calcium in your urine; Parathyroid - calcium in urine ... A 24-hour urine sample is most often needed: On day 1, urinate into the toilet when you wake up in the morning. ...

  9. Interferences of homogentisic acid (HGA) on routine clinical chemistry assays in serum and urine and the implications for biochemical monitoring of patients with alkaptonuria.

    PubMed

    Curtis, S L; Roberts, N B; Ranganath, L R

    2014-05-01

    We have assessed the effect of elevated concentrations of homogentisic acid (HGA) as in alkaptonuria (AKU), on a range of routine chemistry tests in serum and urine. HGA was added to pooled serum and a range of assays was analysed with Roche Modular chemistries. Effects on urine were assessed by diluting normal urine with urine from a patient with AKU, adding HGA to urine and after lowering output of urinary HGA with nitisinone treatment. Serum enzymatic creatinine showed 30% negative interference with 100μmol/L HGA and >50% at 400μmol/L. Serum urate 100 to 480μmol/L was reduced up to 20% at 100 and to 50% with 400μmol/L HGA. Serum cholesterol between 3 and 11mmol/L was reduced by 0.5mmol/L with 400μmol/L HGA. Urine enzymatic creatinine and urate with >2mmol/L HGA showed concentration dependent negative interference up to 80%. A positive interference in urine total protein by benzethonium turbidometric assay was observed, with 10mmol/L HGA equivalent to 1g/L protein. Jaffe creatinine, Na, K, Cl, Mg, Ca, phosphate, ALT, GGT, ALP activities and urea in serum and or urine were not affected by increases in HGA. To avoid interferences by HGA in alkaptonuria concentration of HGA should be established before samples are assayed with peroxidase assays and benzethonium urine protein. Copyright © 2013 The Canadian Society of Clinical Chemists. All rights reserved.

  10. Urinary casts

    MedlinePlus

    ... tubular epithelial casts; Waxy casts; Casts in the urine; Fatty casts; Red blood cell casts; White blood ... The urine sample you provide may need to be from your first morning urine. The sample needs to be ...

  11. Urine Cytology

    MedlinePlus

    ... types of cells were found in your urine sample. You may need to repeat the test. Negative. This means no cancer cells were identified in your urine sample. Atypical. This indicates that some abnormalities were found ...

  12. Variation in Gas and Volatile Compound Emissions from Human Urine as It Ages, Measured by an Electronic Nose.

    PubMed

    Esfahani, Siavash; Sagar, Nidhi M; Kyrou, Ioannis; Mozdiak, Ella; O'Connell, Nicola; Nwokolo, Chuka; Bardhan, Karna D; Arasaradnam, Ramesh P; Covington, James A

    2016-01-25

    The medical profession is becoming ever more interested in the use of gas-phase biomarkers for disease identification and monitoring. This is due in part to its rapid analysis time and low test cost, which makes it attractive for many different clinical arenas. One technology that is showing promise for analyzing these gas-phase biomarkers is the electronic nose--an instrument designed to replicate the biological olfactory system. Of the possible biological media available to "sniff", urine is becoming ever more important as it is easy to collect and to store for batch testing. However, this raises the question of sample storage shelf-life, even at -80 °C. Here we investigated the effect of storage time (years) on stability and reproducibility of total gas/vapour emissions from urine samples. Urine samples from 87 patients with Type 2 Diabetes Mellitus were collected over a four-year period and stored at -80 °C. These samples were then analyzed using FAIMS (field-asymmetric ion mobility spectrometry--a type of electronic nose). It was discovered that gas emissions (concentration and diversity) reduced over time. However, there was less variation in the initial nine months of storage with greater uniformity and stability of concentrations together with tighter clustering of the total number of chemicals released. This suggests that nine months could be considered a general guide to a sample shelf-life.

  13. Effect of Processing Delay and Storage Conditions on Urine Albumin-to-Creatinine Ratio.

    PubMed

    Herrington, William; Illingworth, Nicola; Staplin, Natalie; Kumar, Aishwarya; Storey, Ben; Hrusecka, Renata; Judge, Parminder; Mahmood, Maria; Parish, Sarah; Landray, Martin; Haynes, Richard; Baigent, Colin; Hill, Michael; Clark, Sarah

    2016-10-07

    Because there is substantial biologic intraindividual variation in albumin excretion, randomized trials of albuminuria-reducing therapies may need multiple urine samples to estimate daily urinary albumin excretion. Mailing spot urine samples could offer a convenient and cost-effective method to collect multiple samples, but urine albumin-to-creatinine ratio stability in samples stored at ambient temperatures for several days is unknown. Patients with kidney disease provided fresh urine samples in two tubes (with and without boric acid preservative). Reference aliquots from each participant were analyzed immediately, whereas remaining aliquots were subject to different handling/storage conditions before analysis, including delayed processing for up to 7 days at three different storage temperatures (4°C, 18°C, and 30°C), multiple freeze-thaw cycles, and long-term frozen storage at -80°C, -40°C, and -20°C. We calculated the mean percentage change in urine albumin-to-creatinine ratio for each condition, and we considered samples stable if the 95% confidence interval was within a ±5% threshold. Ninety-three patients provided samples with detectable albuminuria in the reference aliquot. Median (interquartile range) urine albumin-to-creatinine ratio was 87 (20-499) mg/g. The inclusion of preservative had minimal effect on fresh urine albumin-to-creatinine ratio measurements but reduced the changes in albumin and creatinine in samples subject to processing delay and storage conditions. The urine albumin-to-creatinine ratio was stable for 7 days in samples containing preservative at 4°C and 18°C and 2 days when stored at 30°C. It was also stable in samples with preservative after three freeze-thaw cycles and in frozen storage for 6 months at -80°C or -40°C but not at -20°C. Mailed urine samples collected with preservative and received within 7 days if ambient temperature is ≤18°C, or within 2 days if the temperature is higher but does not exceed 30°C, are suitable for the measurement of urine albumin-to-creatinine ratio in randomized trials. Preserved samples frozen to -40°C or -80°C for 6 months before analysis also seem suitable. Copyright © 2016 by the American Society of Nephrology.

  14. Effect of Processing Delay and Storage Conditions on Urine Albumin-to-Creatinine Ratio

    PubMed Central

    Illingworth, Nicola; Staplin, Natalie; Kumar, Aishwarya; Storey, Ben; Hrusecka, Renata; Judge, Parminder; Mahmood, Maria; Parish, Sarah; Landray, Martin; Haynes, Richard; Baigent, Colin; Hill, Michael; Clark, Sarah

    2016-01-01

    Background and objectives Because there is substantial biologic intraindividual variation in albumin excretion, randomized trials of albuminuria-reducing therapies may need multiple urine samples to estimate daily urinary albumin excretion. Mailing spot urine samples could offer a convenient and cost-effective method to collect multiple samples, but urine albumin-to-creatinine ratio stability in samples stored at ambient temperatures for several days is unknown. Design, setting, participants, & measurements Patients with kidney disease provided fresh urine samples in two tubes (with and without boric acid preservative). Reference aliquots from each participant were analyzed immediately, whereas remaining aliquots were subject to different handling/storage conditions before analysis, including delayed processing for up to 7 days at three different storage temperatures (4°C, 18°C, and 30°C), multiple freeze-thaw cycles, and long–term frozen storage at −80°C, −40°C, and −20°C. We calculated the mean percentage change in urine albumin-to-creatinine ratio for each condition, and we considered samples stable if the 95% confidence interval was within a ±5% threshold. Results Ninety-three patients provided samples with detectable albuminuria in the reference aliquot. Median (interquartile range) urine albumin-to-creatinine ratio was 87 (20–499) mg/g. The inclusion of preservative had minimal effect on fresh urine albumin-to-creatinine ratio measurements but reduced the changes in albumin and creatinine in samples subject to processing delay and storage conditions. The urine albumin-to-creatinine ratio was stable for 7 days in samples containing preservative at 4°C and 18°C and 2 days when stored at 30°C. It was also stable in samples with preservative after three freeze-thaw cycles and in frozen storage for 6 months at −80°C or −40°C but not at −20°C. Conclusions Mailed urine samples collected with preservative and received within 7 days if ambient temperature is ≤18°C, or within 2 days if the temperature is higher but does not exceed 30°C, are suitable for the measurement of urine albumin-to-creatinine ratio in randomized trials. Preserved samples frozen to −40°C or −80°C for 6 months before analysis also seem suitable. PMID:27654930

  15. Determining the amounts of urea and glucose in urine of patients with renal complications from diabetes mellitus and hypertension by near-infrared Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Bispo, Jeyse A. M.; Silveira, Landulfo; Vieira, Elzo E. d. S.; Fernandes, Adriana B.

    2013-02-01

    Diabetes mellitus and hypertension diseases are frequently found in the same patient, which if untreated predispose to atherosclerotic and kidney diseases. The objective of this study was to identify potential biomarkers in the urine of diabetic and hypertensive patients through dispersive near-infrared Raman spectroscopy. Urine samples were collected from patients with diabetes and hypertension but no complications (LG), high degree of complications (HG), and control ones: one fraction was submitted to biochemical tests and another one was stored frozen (-20°C) until spectral analysis. Samples were warmed up and placed in an aluminum sample holder for Raman spectra collection using a dispersive spectrometer (830 nm wavelength, 300 mW laser power and 20 s exposure time). Spectra were then submitted to Principal Components Analysis. The PCA loading vectors 1 and 3 revealed spectral features of urea/creatinine and glucose, respectively; the PCA scores showed that patients with diabetes/hypertension (LG and HG) had higher amount of glucose in the urine compared to the normal group (p < 0.05), which can bring serious consequences to patients. Also, the PCA scores showed that the amount of urea decreased in the groups with diabetes/hypertension (p < 0.05), which generates the same concern as it is a marker that has a strong importance in the metabolic changes induced by such diseases. These results, applied to the analysis of urine of patients with diabetes/hypertension, can lead to early diagnostic information of complications and a possible disease prognosis in the patients where no complications from diabetes and hypertension were found.

  16. Length of time domestic dogs (Canis familiaris) spend smelling urine of gonadectomised and intact conspecifics.

    PubMed

    Riach, Anna C; Asquith, Rachel; Fallon, Melissa L D

    2017-09-01

    Domestic dogs (Canis familiaris) use urine to communicate among themselves, however, it is unknown whether the gonadectomy (neutering or spaying) of a dog affects this communication in anyway. Urine samples from 10 intact and 10 gonadectomised, unfamiliar dogs were presented to 12 tester dogs to sniff under controlled conditions in a pilot study. The amount of time the tester dogs spent sniffing each sample was recorded. Overall, tester dogs were recorded smelling the urine of gonadectomised individuals for a longer time. In addition to the type of urine sample, the result is likely to have been influenced by the sex and status (gonadectomised or intact) of the tester dogs. The observed increase in the length of time spent sniffing urine from gonadectomised individuals could be explained by the tester dogs experiencing more difficulty in gaining information from the urine or facing more confusion while analysing the urine compared to the intact urine they have evolved to smell. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. The Impact of Using Different Methods to Assess Completeness of 24-Hour Urine Collection on Estimating Dietary Sodium.

    PubMed

    Wielgosz, Andreas; Robinson, Christopher; Mao, Yang; Jiang, Ying; Campbell, Norm R C; Muthuri, Stella; Morrison, Howard

    2016-06-01

    The standard for population-based surveillance of dietary sodium intake is 24-hour urine testing; however, this may be affected by incomplete urine collection. The impact of different indirect methods of assessing completeness of collection on estimated sodium ingestion has not been established. The authors enlisted 507 participants from an existing community study in 2009 to collect 24-hour urine samples. Several methods of assessing completeness of urine collection were tested. Mean sodium intake varied between 3648 mg/24 h and 7210 mg/24 h depending on the method used. Excluding urine samples collected for longer or shorter than 24 hours increased the estimated urine sodium excretion, even when corrections for the variation in timed collections were applied. Until an accurate method of indirectly assessing completeness of urine collection is identified, the gold standard of administering para-aminobenzoic acid is recommended. Efforts to ensure participants collect complete urine samples are also warranted. ©2015 Wiley Periodicals, Inc.

  18. Protein urine test

    MedlinePlus

    Urine protein; Albumin - urine; Urine albumin; Proteinuria; Albuminuria ... After you provide a urine sample, it is tested. The health care provider uses a dipstick made with a color-sensitive pad. The color change ...

  19. Detection of Circulating Paracoccidioides brasiliensis Antigen in Urine of Paracoccidioidomycosis Patients before and during Treatment

    PubMed Central

    Salina, Margarete Aparecida; Shikanai-Yasuda, Maria Aparecida; Mendes, Rinaldo Poncio; Barraviera, Benedito; Mendes Giannini, Maria José Soares

    1998-01-01

    For the diagnosis and follow-up of paracoccidioidomycosis patients undergoing therapy, we evaluated two methods (immunoblotting and competition enzyme immunoassay) for the detection of circulating antigen in urine samples. A complex pattern of reactivity was observed in the immunoblot test. Bands of 70 and 43 kDa were detected more often in urine samples from patients before treatment. The immunoblot method detected gp43 and gp70 separately or concurrently in 11 (91.7%) of 12 patients, whereas the competition enzyme immunoassay detected antigenuria in 9 (75%) of 12 patients. Both tests appeared to be highly specific (100%), considering that neither fraction detectable by immunoblotting was present in urine samples from the control group. gp43 remained present in the urine samples collected during the treatment period, with a significant decrease in reactivity in samples collected during clinical recovery and increased reactivity in samples collected during relapses. Reactivity of some bands was also detected in urine specimens from patients with “apparent cure.” The detection of Paracoccidioides brasiliensis antigens in urine appears to be a promising method for diagnosing infection, for evaluating the efficacy of treatment, and for detecting relapse. PMID:9620407

  20. Dipstick Spot urine pH does not accurately represent 24 hour urine PH measured by an electrode.

    PubMed

    Omar, Mohamed; Sarkissian, Carl; Jianbo, Li; Calle, Juan; Monga, Manoj

    2016-01-01

    To determine whether spot urine pH measured by dipstick is an accurate representation of 24 hours urine pH measured by an electrode. We retrospectively reviewed urine pH results of patients who presented to the urology stone clinic. For each patient we recorded the most recente pH result measured by dipstick from a spot urine sample that preceded the result of a 24-hour urine pH measured by the use of a pH electrode. Patients were excluded if there was a change in medications or dietary recommendations or if the two samples were more than 4 months apart. A difference of more than 0.5 pH was considered na inaccurate result. A total 600 patients were retrospectively reviewed for the pH results. The mean difference in pH between spot urine value and the 24 hours collection values was 0.52±0.45 pH. Higher pH was associated with lower accuracy (p<0.001). The accuracy of spot urine samples to predict 24-hour pH values of <5.5 was 68.9%, 68.2% for 5.5 to 6.5 and 35% for >6.5. Samples taken more than 75 days apart had only 49% the accuracy of more recent samples (p<0.002). The overall accuracy is lower than 80% (p<0.001). Influence of diurnal variation was not significant (p=0.588). Spot urine pH by dipstick is not an accurate method for evaluation of the patients with urolithiasis. Patients with alkaline urine are more prone to error with reliance on spot urine pH.

  1. Collection and storage of urine specimens for measurement of urolithiasis risk factors.

    PubMed

    Wu, Wenqi; Yang, Dong; Tiselius, Hans-Goran; Ou, Lili; Mai, Zanlin; Chen, Kang; Zhu, Hanliang; Xu, Shaohong; Zhao, Zhijian; Zeng, Guohua

    2015-02-01

    To evaluate how different methods for storage and preservation of urine samples affected the outcome of analysis of risk factors for stone formation. Spot urine samples were collected from 21 healthy volunteers. Each fresh urine sample was divided into ten 10-mL aliquots: 2 without preservative, 2 with thymol, 2 with toluene, 2 with hydrochloric acid (HCl), and 2 with sodium azide. One sample of each pair was stored at 4 °C and the other at room temperature. The concentrations of calcium, magnesium, sodium, phosphate, urate, oxalate, citrate, and pH in each urine sample were analyzed immediately after collection (0 hour) and after 24 and 48 hours. There were no significant differences in calcium, oxalate, magnesium, phosphate, sodium, urate or pH (without acidification) between samples with different preservation methods (P >.05). Urinary citrate, however, was significantly lower in the urine collected with HCl than when other preservatives were used, both at room temperature and at 4 °C. Urine pH was significantly higher after 48 hours than after 24 hours, whether the samples were stored at room temperature or at 4 °C. Antibacterial preservatives (eg, thymol or toluene) can be recommended as preservatives for 24-hour urine collections. Ideally, the samples should be stored at 4 °C. When HCl is used as a preservative, it seems essential to neutralize the samples before analysis. This is particularly obvious with the chromatographic method used for analysis of citrate that was used in this study. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Effect of a commercial anion dietary supplement on acid-base balance, urine volume, and urinary ion excretion in male goats fed oat or grass hay diets.

    PubMed

    Stratton-Phelps, Meri; House, John K

    2004-10-01

    To determine whether feeding a commercial anionic dietary supplement as a urinary acidifier to male goats may be useful for management of urolithiasis. 8 adult sexually intact male Toggenburg, Saanen, and Nubian goats. Goats were randomly assigned by age-, breed-, and weight-matched pairs to an oat or grass hay diet that was fed for 12 days. On days 13 to 14 (early sample collection time before supplementation), measurements were made of blood and urine sodium, potassium, calcium, magnesium, chloride, phosphorus, and sulfur concentrations; blood and urine pH; urine production; and water consumption. During the next 28 days, the anionic dietary supplement was added to the oat and grass hay diets to achieve a dietary cation-anion difference of 0 mEq/100g of dry matter. Blood and urine samples were analyzed during dietary supplementation on days 12 to 13 (middle sample collection time) and 27 to 28 (late sample collection time). Blood bicarbonate, pH, and urine pH of goats fed grass hay and goats fed oat hay were significantly decreased during the middle and late sample collection times, compared with the early sample collection time. Water consumption and urine production in all goats increased significantly during the late sample collection time, compared with the early sample collection time. The anionic dietary supplement used in our study increases urine volume, alters urine ion concentrations, and is an efficacious urinary acidifier in goats. Goats treated with prolonged anionic dietary supplementation should be monitored for secondary osteoporosis from chronic urinary calcium loss.

  3. 5C.07: A METHOD TO ESTIMATE 24-HOUR SODIUM EXCRETION THROUGH SPOT URINE SAMPLES AND ITS APPLICATION VALUE FOR TARGET-ORGAN DAMAGE ASSESSMENT.

    PubMed

    Wang, H; Zhao, L; Xi, Y; Sun, N

    2015-06-01

    24-h urine sodium excretion is considered the most reliable method to evaluate the salt intakes. However, this method is cumbersome. So we want to develop formulas to estimate 24-h urinary sodium excretion using spot urinary samples in Chinese hypertensive population and explore the application value of this method in salt intake assessment and target organ damage. 1. We enrolled 510 cases of hospitalized patients with hypertension, 2/3 of them were arranged randomly to formula group to develop a new formula and the remainings were used to test the performance of the formula. All participants were instructed to collect a 24-h urine sample, a second morning voiding urine sample (SMU), and a post-meridiem urine sample in the late afternoon or early evening, prior to the evening meal (PMU). All samples were sent to measure sodium and creatinine concentration.2. We compared the differences of office blood pressure, 24-hour ambulatory blood pressure and left ventricular hypertrophy, vascular stiffness and urine protein among groups of different sodium intake. 24hour sodium excretion formulas was obtained using SMU and PMU respectively, which have good cosistency. The difference between the estimated and measured values in sodium excretion is 12.66mmol/day (SMU) and 9.41mmol/day (PM), to be equal to 0.7 g (SMU) and 0.6 g (PM) salt intake. Comparing with Kawasaki and Tanaka method, the new formula shows the lower degree of deviation, and higher accuracy and precision. Blood pressure of high urinary sodium group is higher than that in low urinary sodium group (P < 0.05). Left ventricular hypertrophy and urinary albumin/creatinine aggravated with the salt intake increase, this has eliminated the influence of other factors. All of morphologies of the relationship between ambulatory arterial stiffness index, pulse wave velocity and carotid intima-media thickness with quartiles of sodium intake resembled a J-shaped curve. In Chinese hypertensive population, the formulas to estimate 24-h urinary sodium using spot urinary samples spot urine are considered useful for estimating the mean level of population salt intake, and have a role in evaluating target organ damage.

  4. Urine stability and steroid profile: towards a screening index of urine sample degradation for anti-doping purpose.

    PubMed

    Mazzarino, Monica; Abate, Maria Gabriella; Alocci, Roberto; Rossi, Francesca; Stinchelli, Raffaella; Molaioni, Francesco; de la Torre, Xavier; Botrè, Francesco

    2011-01-10

    The presence of microorganisms in urine samples, under favourable conditions of storage and transportation, may alter the concentration of steroid hormones, thus altering the correct evaluation of the urinary steroid profile in doping control analysis. According to the rules of the World Anti-Doping Agency (WADA technical document TD2004 EAAS), a testosterone deconjugation higher than 5% and the presence of 5α-androstane-3,17-dione and 5β-androstane-3,17-dione in the deconjugated fraction, are reliable indicators of urine degradation. The determination of these markers would require an additional quantitative analysis since the steroids screening analysis, in anti-doping laboratories, is performed in the total (free+conjugated) fraction. The aim of this work is therefore to establish reliable threshold values for some representative compounds (namely 5α-androstane-3,17-dione and 5β-androstane-3,17-dione) in the total fraction in order to predict directly at the screening stage the potential microbial degradation of the urine samples. Preliminary evidence on the most suitable degradation indexes has been obtained by measuring the urinary concentration of testosterone, epitestosterone, 5α-androstane-3,17-dione and 5β-androstane-3,17-dione by gas chromatography-mass spectrometric every day for 15 days in the deconjugated, glucuronide and total fraction of 10 pools of urines from 60 healthy subjects, stored under different pH and temperature conditions, and isolating the samples with one or more markers of degradation according to the WADA technical document TD2004EAAS. The threshold values for 5α-androstane-3,17-dione and 5β-androstane-3,17-dione were therefore obtained correlating the testosterone deconjugation rate with the urinary concentrations of 5α-androstane-3,17-dione and 5β-androstane-3,17-dione in the total fraction. The threshold values suggested as indexes of urine degradation in the total fraction were: 10 ng mL(-1) for 5α-androstane-3,17-dione and 20 ng mL(-1) for 5β-androstane-3,17-dione. The validity of this approach was confirmed by the analysis of routine samples for more than five months (i.e. on a total of more than 4000 urine samples): samples with a concentration of total 5α-androstane-3,17-dione and 5β-androstane-3,17-dione higher than the threshold values showed a percentage of free testosterone higher than 5 of its total amount; whereas free testosterone in a percentage higher than 5 of its total amount was not detected in urines with a concentration of total 5α-androstane-3,17-dione and 5β-androstane-3,17-dione lower than the threshold values. Copyright © 2010 Elsevier B.V. All rights reserved.

  5. Quantifying creatinine and urea in human urine through Raman spectroscopy aiming at diagnosis of kidney disease

    NASA Astrophysics Data System (ADS)

    Saatkamp, Cassiano Junior; de Almeida, Maurício Liberal; Bispo, Jeyse Aliana Martins; Pinheiro, Antonio Luiz Barbosa; Fernandes, Adriana Barrinha; Silveira, Landulfo, Jr.

    2016-03-01

    Due to their importance in the regulation of metabolites, the kidneys need continuous monitoring to check for correct functioning, mainly by urea and creatinine urinalysis. This study aimed to develop a model to estimate the concentrations of urea and creatinine in urine by means of Raman spectroscopy (RS) that could be used to diagnose kidney disease. Midstream urine samples were obtained from 54 volunteers with no kidney complaints. Samples were subjected to a standard colorimetric assay of urea and creatinine and submitted to spectroscopic analysis by means of a dispersive Raman spectrometer (830 nm, 350 mW, 30 s). The Raman spectra of urine showed peaks related mainly to urea and creatinine. Partial least squares models were developed using selected Raman bands related to urea and creatinine and the biochemical concentrations in urine measured by the colorimetric method, resulting in r=0.90 and 0.91 for urea and creatinine, respectively, with root mean square error of cross-validation (RMSEcv) of 312 and 25.2 mg/dL, respectively. RS may become a technique for rapid urinalysis, with concentration errors suitable for population screening aimed at the prevention of renal diseases.

  6. Confirmatory analysis of 17beta-boldenone, 17alpha-boldenone and androsta-1,4-diene-3,17-dione in bovine urine, faeces, feed and skin swab samples by liquid chromatography-electrospray ionisation tandem mass spectrometry.

    PubMed

    Nielen, Michel W F; Rutgers, Paula; van Bennekom, Eric O; Lasaroms, Johan J P; van Rhijn, J A Hans

    2004-03-05

    The origin, i.e. natural occurrence or illegal treatment, of findings of 17alpha-boldenone (alpha-Bol) and 17beta-boldenone (beta-Bol) in urine and faeces of cattle is under debate within the European Union. A liquid chromatographic positive ion electrospray tandem mass spectrometric method is presented for the confirmatory analysis of 17beta-boldenone, 17alpha-boldenone and an important metabolite/precursor androsta-1,4-diene-3,17-dione (ADD), using deuterium-labelled 17beta-boldenone (beta-Bol-d3) as internal standard. Detailed sample preparation procedures were developed for a variety of sample matrices such as bovine urine, faeces, feed and skin swab samples. The method was validated as a quantitative confirmatory method according to the latest EU guidelines and shows good precision, linearity and accuracy data, and CCalpha and CCbeta values of 0.1-0.3 and 0.4-1.0 ng/ml, respectively. Currently, the method has been successfully applied to suspect urine samples for more than a year, and occasionally to faeces, feed and swab samples as well. Results obtained from untreated and treated animals are given and their impact on the debate about the origin of residues of 17beta-boldenone is critically discussed. Finally, preliminary data about the degree of conjugation of boldenone residues are presented and a simple procedure for discrimination between residues from abuse versus natural origin is proposed.

  7. Comparative analysis of detection methods for congenital cytomegalovirus infection in a Guinea pig model.

    PubMed

    Park, Albert H; Mann, David; Error, Marc E; Miller, Matthew; Firpo, Matthew A; Wang, Yong; Alder, Stephen C; Schleiss, Mark R

    2013-01-01

    To assess the validity of the guinea pig as a model for congenital cytomegalovirus (CMV) infection by comparing the effectiveness of detecting the virus by real-time polymerase chain reaction (PCR) in blood, urine, and saliva. Case-control study. Academic research. Eleven pregnant Hartley guinea pigs. Blood, urine, and saliva samples were collected from guinea pig pups delivered from pregnant dams inoculated with guinea pig CMV. These samples were then evaluated for the presence of guinea pig CMV by real-time PCR assuming 100% transmission. Thirty-one pups delivered from 9 inoculated pregnant dams and 8 uninfected control pups underwent testing for guinea pig CMV and for auditory brainstem response hearing loss. Repeated-measures analysis of variance demonstrated no statistically significantly lower weight for the infected pups compared with the noninfected control pups. Six infected pups demonstrated auditory brainstem response hearing loss. The sensitivity and specificity of the real-time PCR assay on saliva samples were 74.2% and 100.0%, respectively. The sensitivity of the real-time PCR on blood and urine samples was significantly lower than that on saliva samples. Real-time PCR assays of blood, urine, and saliva revealed that saliva samples show high sensitivity and specificity for detecting congenital CMV infection in guinea pigs. This finding is consistent with recent screening studies in human newborns. The guinea pig may be a good animal model in which to compare different diagnostic assays for congenital CMV infection.

  8. NHEXAS PHASE I ARIZONA STUDY--METALS IN URINE ANALYTICAL RESULTS

    EPA Science Inventory

    The Metals in Urine data set contains analytical results for measurements of up to 6 metals in 176 urine samples over 176 households. Each sample was collected from the primary respondent within each household during Stage III of the NHEXAS study. The sample consists of the fir...

  9. Urine sampling and collection system

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Mangialardi, J. K.; Reinhardt, C. G.

    1971-01-01

    This specification defines the performance and design requirements for the urine sampling and collection system engineering model and establishes requirements for its design, development, and test. The model shall provide conceptual verification of a system applicable to manned space flight which will automatically provide for collection, volume sensing, and sampling of urine.

  10. Stability of Drugs of Abuse in Urine Samples at Room Temperature by Use of a Salts Mixture.

    PubMed

    Pellegrini, Manuela; Graziano, Silvia; Mastrobattista, Luisa; Minutillo, Adele; Busardo, Francesco Paolo; Scarsella, Gianfranco

    2017-01-01

    It has long been recognized that ensuring analyte stability is of crucial importance in the use of any quantitative bioanalytical method. As analyses are usually not performed directly after collection of the biological samples, but after these have been processed and stored, it is essential that analyte stability can be maintained at storage conditions to ensure that the obtained concentration results adequately reflect those directly after sampling. The conservation of urine samples in refrigerated/ frozen conditions is strongly recommended; but not always feasible. The aim of this study was to assess the stability of some well-known drugs of abuse methamphetamine (MA), 11-nor-9-carboxy-Δ9- tetrahydrocannabinol (THC-COOH), benzoylecgonine (BE), and morphine (MOR) in urine samples kept at room temperature by adding a salt mixture (sodium citrate, sodium ascorbate, borax). Two different urine samples were prepared with and without salt mixture, stored at room temperature and then analyzed by gas chromatography-mass spectrometry at 0, 1, 7, 15, and 30 days after collection/preparation to look for eventual analyte degradation. Methamphetamine showed no significant changes with respect to the time of collection/ preparation (T0) up to 7 days later (T7), with or without salt mixture addiction. Then a significant degradation occurred in both salted and non salted urine. BE decrease was observed starting from day 1 after sample collection in salted and not salted samples, respectively. Salt addition seemed to reduce at least the initial BE degradation, with a significant difference (p<0.001) at 7 and 15 days of storage. However, the degradation was not more prevented in salted samples at 30 days of storage. A 20% decrease of MOR concentration was observed starting from day 1 after collection/preparation, both in salted and not salted samples with no subsequent decrease. With regard to THCCOOH, a significant decrease was observed starting from 7 days after collection/preparation, with of without adding the salt mixture. However, when comparing salted versus non salted samples at each time point, a statistically significant difference was observed at 7 and 30 days of storage. The results obtained indicate that the degradation of MA, THC-COOH and BE in urine samples kept at room temperature can be slowed by the addition of the salt mixture, whereas it seems to be ineffective in samples containing MOR. This evidence has to be taken into account, in the eventuality of using salted urine to prevent in a certain extent abuse of above-reported drugs of abuse. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  11. Urinary metabolic insights into host-gut microbial interactions in healthy and IBD children

    PubMed Central

    Martin, Francois-Pierre; Su, Ming-Ming; Xie, Guo-Xiang; Guiraud, Seu Ping; Kussmann, Martin; Godin, Jean-Philippe; Jia, Wei; Nydegger, Andreas

    2017-01-01

    AIM To identify metabolic signatures in urine samples from healthy and inflammatory bowel disease (IBD) children. METHODS We applied liquid chromatography and gas chromatography coupled to targeted mass spectrometry (MS)-based metabolite profiling to identify and quantify bile acids and host-gut microbial metabolites in urine samples collected from 21 pediatric IBD patients monitored three times over one year (baseline, 6 and 12 mo), and 27 age- and gender-matched healthy children. RESULTS urinary metabolic profiles of IBD children differ significantly from healthy controls. Such metabolic differences encompass central energy metabolism, amino acids, bile acids and gut microbial metabolites. In particular, levels of pyroglutamic acid, glutamic acid, glycine and cysteine, were significantly higher in IBD children in the course of the study. This suggests that glutathione cannot be optimally synthesized and replenished. Whilst alterations of the enterohepatic circulation of bile acids in pediatric IBD patients is known, we show here that non-invasive urinary bile acid profiling can assess those altered hepatic and intestinal barrier dysfunctions. CONCLUSION The present study shows how non-invasive sampling of urine followed by targeted MS-based metabonomic analysis can elucidate and monitor the metabolic status of children with different GI health/disease status. PMID:28611517

  12. Filter paper saturated by urine sample in metabolic disorders detection by proton magnetic resonance spectroscopy.

    PubMed

    Blasco, Hélène; Garrigue, Marie-Ange; De Vos, Aymeric; Antar, Catherine; Labarthe, François; Maillot, François; Andres, Christian R; Nadal-Desbarats, Lydie

    2010-02-01

    NMR spectroscopy of urine samples is able to diagnose many inborn errors of metabolism (IEM). However, urinary metabolites have a poor stability, requiring special care for routine analysis (storage of urine at -20 or -80 degrees C, fast transport). The aim of our study was to investigate the reliability of dried urine filter paper for urine storage and transport and to evaluate the ability of NMR to detect several IEM using this method. Urine samples from five healthy subjects were analyzed by (1)H NMR following different storage conditions (-20 vs 4 degrees C vs dried on filter paper) and at different time points (24 h, 48 h, 96 h, and 7 days). Urine pattern of fresh urine was considered as a reference. We analyzed the conservation of some amino acids and organic acids using Bland and Altman plot with intraclass correlation coefficient determination. Then, we evaluated the use of filter paper to detect four different IEM (methylmalonic and isovaleric acidurias, ornithine transcarbamylase deficiency, and cystinuria). Analysis of urine samples from healthy subjects revealed a high stability of studied molecules (ICC > 0.8) even after 7 days of storage on filter paper. Moreover, an excellent preservation of metabolites specifically accumulated in IEM was observed when analysis of dried urine filter paper was compared to fresh urine (coefficient of variation < 15%). This preliminary study demonstrates that storage of dried urine on filter paper is reliable for (1)H NMR spectroscopy analysis. Preservation of urine molecules over time using that method is convenient for routine clinical practice.

  13. Measurements of C-reactive protein (CRP) and nerve-growth-factor (NGF) concentrations in serum and urine samples of dogs with neurologic disorders.

    PubMed

    Kordass, Ulrike; Carlson, Regina; Stein, Veronika Maria; Tipold, Andrea

    2016-01-08

    The purpose of this study was to prove the hypothesis that C-reactive protein (CRP) and nerve growth factor (NGF) may be potential biomarkers for lower urinary tract disorders and may be able to distinguish between micturition dysfunctions of different origin in dogs with spinal cord diseases. NGF- and CRP- concentrations were measured in serum and urine samples using specific ELISA-Kits. Results in urine were standardized by urine-creatinine levels. CRP in serum was detectable in 32/76 and in urine samples in 40/76 patients. NGF could be measured in all serum and in 70/76 urine samples. Urinary CRP concentrations were significantly higher in dogs with micturition dysfunction (p = 0.0009) and in dogs with different neurological diseases (p = 0.0020) compared to the control group. However, comparing dogs with spinal cord disorders with and without associated micturition dysfunction no significant difference could be detected for NGF and CRP values in urine or serum samples. Additionally, levels did not decrease significantly, when measured at the time when the dogs regained the ability to urinate properly (urinary NGF p = 0.7962; urinary CRP p = 0.078). Urine samples with bacteria and/or leukocytes had no significant increase in urinary NGF (p = 0.1112) or CRP (p = 0.0534) concentrations, but higher CRP-levels in urine from dogs with cystitis were found compared to dogs without signs of cystitis. From these data we conclude that neither CRP nor NGF in urine or serum can be considered as reliable biomarkers for micturition disorders in dogs with spinal cord disorders in a clinical setting, but their production might be part of the pathogenesis of such disorders. Significantly higher levels of CRP could be found in the urine of dogs with micturition dysfunctions compared to control dogs. This phenomenon could potentially be explained by unspecific extrahepatic CRP production by smooth muscle cells in the dilated bladder.

  14. Comparison of urine specimen collection times and testing fractions for the detection of high-risk human papillomavirus and high-grade cervical precancer.

    PubMed

    Senkomago, V; Des Marais, A C; Rahangdale, L; Vibat, C R T; Erlander, M G; Smith, J S

    2016-01-01

    Urine testing for high-risk human papillomavirus (HR-HPV) detection could provide a non-invasive, simple method for cervical cancer screening. We examined whether HR-HPV detection is affected by urine collection time, portion of urine stream, or urine fraction tested, and assessed the performance of HR-HPV testing in urine for detection of cervical intraepithelial neoplasia grade II or worse (CIN2+). A total of 37 female colposcopy clinic attendees, ≥ 30 years, provided three urine samples: "first void" urine collected at home, and "initial stream" and "mid-stream" urine samples collected at the clinic later in the day. Self- and physician-collected brush specimens were obtained at the same clinic visit. Colposcopy was performed and directed biopsies obtained if clinically indicated. For each urine sample, HR-HPV DNA testing was conducted for unfractionated, pellet, and supernatant fractions using the Trovagene test. HR-HPV mRNA testing was performed on brush specimens using the Aptima HPV assay. HR-HPV prevalence was similar in unfractionated and pellet fractions of all urine samples. For supernatant urine fractions, HR-HPV prevalence appeared lower in mid-stream urine (56.8%[40.8-72.7%]) than in initial stream urine (75.7%[61.9-89.5%]). Sensitivity of CIN2+ detection was identical for initial stream urine and physician-collected cervical specimen (89.9%[95%CI=62.7-99.6%]), and similar to self-collected vaginal specimen (79.1%[48.1-96.6%]). This is among the first studies to compare methodologies for collection and processing of urine for HR-HPV detection. HR-HPV prevalence was similar in first void and initial stream urine, and was highly sensitive for CIN2+ detection. Additional research in a larger and general screening population is needed. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Detection of anabolic androgenic steroid abuse in doping control using mammalian reporter gene bioassays.

    PubMed

    Houtman, Corine J; Sterk, Saskia S; van de Heijning, Monique P M; Brouwer, Abraham; Stephany, Rainer W; van der Burg, Bart; Sonneveld, Edwin

    2009-04-01

    Anabolic androgenic steroids (AAS) are a class of steroid hormones related to the male hormone testosterone. They are frequently detected as drugs in sport doping control. Being similar to or derived from natural male hormones, AAS share the activation of the androgen receptor (AR) as common mechanism of action. The mammalian androgen responsive reporter gene assay (AR CALUX bioassay), measuring compounds interacting with the AR can be used for the analysis of AAS without the necessity of knowing their chemical structure beforehand, whereas current chemical-analytical approaches may have difficulty in detecting compounds with unknown structures, such as designer steroids. This study demonstrated that AAS prohibited in sports and potential designer AAS can be detected with this AR reporter gene assay, but that also additional steroid activities of AAS could be found using additional mammalian bioassays for other types of steroid hormones. Mixtures of AAS were found to behave additively in the AR reporter gene assay showing that it is possible to use this method for complex mixtures as are found in doping control samples, including mixtures that are a result of multi drug use. To test if mammalian reporter gene assays could be used for the detection of AAS in urine samples, background steroidal activities were measured. AAS-spiked urine samples, mimicking doping positive samples, showed significantly higher androgenic activities than unspiked samples. GC-MS analysis of endogenous androgens and AR reporter gene assay analysis of urine samples showed how a combined chemical-analytical and bioassay approach can be used to identify samples containing AAS. The results indicate that the AR reporter gene assay, in addition to chemical-analytical methods, can be a valuable tool for the analysis of AAS for doping control purposes.

  16. Development of a universal metabolome-standard method for long-term LC-MS metabolome profiling and its application for bladder cancer urine-metabolite-biomarker discovery.

    PubMed

    Peng, Jun; Chen, Yi-Ting; Chen, Chien-Lun; Li, Liang

    2014-07-01

    Large-scale metabolomics study requires a quantitative method to generate metabolome data over an extended period with high technical reproducibility. We report a universal metabolome-standard (UMS) method, in conjunction with chemical isotope labeling liquid chromatography-mass spectrometry (LC-MS), to provide long-term analytical reproducibility and facilitate metabolome comparison among different data sets. In this method, UMS of a specific type of sample labeled by an isotope reagent is prepared a priori. The UMS is spiked into any individual samples labeled by another form of the isotope reagent in a metabolomics study. The resultant mixture is analyzed by LC-MS to provide relative quantification of the individual sample metabolome to UMS. UMS is independent of a study undertaking as well as the time of analysis and useful for profiling the same type of samples in multiple studies. In this work, the UMS method was developed and applied for a urine metabolomics study of bladder cancer. UMS of human urine was prepared by (13)C2-dansyl labeling of a pooled sample from 20 healthy individuals. This method was first used to profile the discovery samples to generate a list of putative biomarkers potentially useful for bladder cancer detection and then used to analyze the verification samples about one year later. Within the discovery sample set, three-month technical reproducibility was examined using a quality control sample and found a mean CV of 13.9% and median CV of 9.4% for all the quantified metabolites. Statistical analysis of the urine metabolome data showed a clear separation between the bladder cancer group and the control group from the discovery samples, which was confirmed by the verification samples. Receiver operating characteristic (ROC) test showed that the area under the curve (AUC) was 0.956 in the discovery data set and 0.935 in the verification data set. These results demonstrated the utility of the UMS method for long-term metabolomics and discovering potential metabolite biomarkers for diagnosis of bladder cancer.

  17. A high-performance liquid chromatographic-tandem mass spectrometric method for the determination of ethyl glucuronide and ethyl sulfate in urine validated according to forensic guidelines.

    PubMed

    Albermann, M E; Musshoff, F; Madea, B

    2012-01-01

    Ethyl glucuronide (EtG) and ethyl sulfate (EtS) are powerful markers for alcohol intake and abuse. Several analytical procedures for the quantification of EtG and EtG in serum and urine have been developed so far. Many of the published methods show limits of detections (LODs) or limits of quantifications (LOQs) for EtG in urine within the range of 0.1 mg/L or higher. Since this is the actual cutoff value for proving abstinence in Germany, problems may occur if urine samples are highly diluted. In this paper, the validation of a highly sensitive, fast and simple LC-MS-MS for the determination of EtG and EtS in urine is described. The calibration curves for EtG and EtS is linear over the whole range (0.025-2.0 mg/L). Very low detection limits can be achieved (LOD: EtG 0.005 mg/L, EtS 0.005 mg/L; and LOQ: EtG 0.019 mg/L, EtS 0.015 mg/L). All data for selectivity, precision and accuracy, recovery, as well as for the processed sample and the freeze/thaw stability, comply with the guidelines of the German Society of Toxicological and Forensic Chemistry. Strong matrix-related effects can be compensated for by using an internal standard. Finally, the applicability of the procedure is proven by analysis of 87 human urine samples and by successful participation in interlaboratory comparison tests. © The Author [2011]. Published by Oxford University Press. All rights reserved.

  18. Evaluation of urine for Leishmania infantum DNA detection by real-time quantitative PCR.

    PubMed

    Pessoa-E-Silva, Rômulo; Mendonça Trajano-Silva, Lays Adrianne; Lopes da Silva, Maria Almerice; da Cunha Gonçalves-de-Albuquerque, Suênia; de Goes, Tayná Correia; Silva de Morais, Rayana Carla; Lopes de Melo, Fábio; de Paiva-Cavalcanti, Milena

    2016-12-01

    The availability of some sorts of biological samples which require noninvasive collection methods has led to an even greater interest in applying molecular biology on visceral leishmaniasis (VL) diagnosis, since these samples increase the safety and comfort of both patients and health professionals. In this context, this work aimed to evaluate the suitability of the urine as a specimen for Leishmania infantum kinetoplast DNA detection by real-time quantitative PCR (qPCR). Subsequent to the reproducibility analysis, the detection limit of the qPCR assay was set at 5fg (~0.025 parasites) per μL of urine. From the comparative analysis performed with a set of diagnostic criteria (serological and molecular reference tests), concordance value of 96.08% was obtained (VL-suspected and HIV/AIDS patients, n=51) (P>0.05). Kappa coefficient (95% CI) indicated a good agreement between the test and the set of diagnostic criteria (k=0.778±0.151). The detection of Leishmania DNA in urine by qPCR was possible in untreated individuals, and in those with or without suggestive renal impairment. Fast depletion of the parasite's DNA in urine after treatment (from one dose of meglumine antimoniate) was suggested by negative qPCR results, thus indicating it as a potential alternative specimen to follow up the efficacy of therapeutic approaches. Even when evaluated in a clinically heterogeneous set of patients, the urine showed good prospect as sample for VL diagnosis by qPCR, also indicating a good negative predictive value for untreated suspected patients. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Elimination kinetics of metals after an accidental exposure to welding fumes.

    PubMed

    Schaller, Karl H; Csanady, György; Filser, Johannes; Jüngert, Barbara; Drexler, Hans

    2007-07-01

    We had the opportunity to study the kinetics of metals in blood and urine samples of a flame-sprayer exposed to high accident-prone workplace exposure. We measured over 1 year, the nickel, aluminium, and chromium concentrations in blood and urine specimens after exposure. On this basis, we evaluated the corresponding half-lives. Blood and urine sampling were carried out five times after accidental exposure over a period of 1 year. The metals were analysed by graphite furnace atomic absorption spectrometry and Zeeman compensation with reliable methods. Either a mono-exponential or a bi-exponential function was fitted to the concentration-time courses of selected metals using weighted least squares non-linear regression analysis. The amount excreted in urine was calculated integrating the urinary decay curve and multiplying with the daily creatinine excretion. The first examination was carried out 15 days after exposure. The mean aluminium concentration in plasma was 8.2 microg/l and in urine, 58.4 microg/g creatinine. The mean nickel concentration in blood was 59.6 microg/l and the excretion in urine 700 microg/g creatinine. The mean chromium level in blood was 1.4 microg/l in urine, 7.4 microg/g creatinine. For the three elements, the metal concentrations in blood and urine exceeded the reference values at least in the initial phase. For nickel, the German biological threshold limit values (EKA) were exceeded. Aluminium showed a mono-exponential decay, whereas the elimination of chromium and nickel was biphasic in biological fluids of the accidentally exposed welder. The half-lives were as follows: for aluminium 140 days (urine) and 160 days (plasma); for chromium 40 and 730 days (urine); for nickel 25 and 610 days (urine) as well as 30 and 240 days (blood). The renal clearance of aluminium and nickel was about 2 l/h estimated for the last monitoring day.

  20. Ionic Liquid Dispersive Liquid-Liquid Microextraction Method for the Determination of Irinotecan, an Anticancer Drug, in Water and Urine Samples Using UV-Vis Spectrophotometry.

    PubMed

    Uysal, Deniz; Karadaş, Cennet; Kara, Derya

    2017-05-01

    A new, simple, efficient, and environmentally friendly ionic liquid dispersive liquid-liquid microextraction method was developed for the determination of irinotecan, an anticancer drug, in water and urine samples using UV-Vis spectrophotometry. The ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate was used as the extraction solvent, and ethanol was used as the disperser solvent. The main parameters affecting the extraction efficiency, including sample pH, volume of the ionic liquid, choice of the dispersive solvent and its volume, concentration of NaCl, and extraction and centrifugation times, were investigated and optimized. The effect of interfering species on the recovery of irinotecan was also examined. Under optimal conditions, the LOD (3σ) was 48.7 μg/L without any preconcentration. Because the urine sample was diluted 10-fold, the LOD for urine would be 487 μg/L. However, this could be improved 16-fold if preconcentration using a 40 mL aliquot of the sample is used. The proposed method was successfully applied to the determination of irinotecan in tap water, river water, and urine samples spiked with 10.20 mg/L for the water samples and 8.32 mg/L for the urine sample. The average recovery values of irinotecan determined were 99.1% for tap water, 109.4% for river water, and 96.1% for urine.

  1. Comparison of urine analysis using manual and sedimentation methods.

    PubMed

    Kurup, R; Leich, M

    2012-06-01

    Microscopic examination of urine sediment is an essential part in the evaluation of renal and urinary tract diseases. Traditionally, urine sediments are assessed by microscopic examination of centrifuged urine. However the current method used by the Georgetown Public Hospital Corporation Medical Laboratory involves uncentrifuged urine. To encourage high level of care, the results provided to the physician must be accurate and reliable for proper diagnosis. The aim of this study is to determine whether the centrifuge method is more clinically significant than the uncentrifuged method. In this study, a comparison between the results obtained from centrifuged and uncentrifuged methods were performed. A total of 167 urine samples were randomly collected and analysed during the period April-May 2010 at the Medical Laboratory, Georgetown Public Hospital Corporation. The urine samples were first analysed microscopically by the uncentrifuged, and then by the centrifuged method. The results obtained from both methods were recorded in a log book. These results were then entered into a database created in Microsoft Excel, and analysed for differences and similarities using this application. Analysis was further done in SPSS software to compare the results using Pearson ' correlation. When compared using Pearson's correlation coefficient analysis, both methods showed a good correlation between urinary sediments with the exception of white bloods cells. The centrifuged method had a slightly higher identification rate for all of the parameters. There is substantial agreement between the centrifuged and uncentrifuged methods. However the uncentrifuged method provides for a rapid turnaround time.

  2. Determination of drug residues in urine of dogs receiving anti-cancer chemotherapy by liquid chromatography-electrospray ionization- tandem mass spectrometry: is there an environmental or occupational risk?

    PubMed

    Hamscher, Gerd; Mohring, Siegrun A I; Knobloch, Anna; Eberle, Nina; Nau, Heinz; Nolte, Ingo; Simon, Daniela

    2010-04-01

    Cytotoxic drugs, previously used only in human medicine, are increasingly utilized for cancer treatment in veterinary practice. We developed and validated a liquid chromatography (LC)-electrospray ionization-tandem mass spectrometry (MS-MS) method to determine vincristine, vinblastine, cyclophosphamide, and doxorubicin in canine urine. Sample pretreatment consisted of liquid-liquid extraction, and LC separation was carried out on an RP C(18) column employing a 0.5% formic acid/methanol gradient system. The analytes were detected in positive ion mode using the MS-MS scan mode. The mean recoveries in six different urine samples were between 64.2% and 86.9%. Limits of quantitation were 0.5 microg/L for vincristine and vinblastine, 1 microg/L for cyclophosphamide, and 5 microg/L for doxorubicin; limits of detection were approximately 0.25 microg/L for vincristine, vinblastine, and cyclophosphamide and 0.5 microg/L for doxorubicin. It could be demonstrated that all investigated drugs are found in urine of dogs undergoing chemotherapy. In samples from day 1 after chemotherapy, as much as 63 microg/L vincristine, 111 microg/L vinblastine, and 762 microg/L doxorubicin could be detected. Cyclophosphamide showed only minor concentrations on day 1, but up to 2583 microg/L could be found directly after chemotherapy. These initial data show that there might be a potential contamination risk when administering cytotoxics in veterinary medicine.

  3. Multiresidue determination of chlorophenoxy acid herbicides in human urine samples by use of solid-phase extraction and capillary LC-UV detection.

    PubMed

    Rosales-Conrado, N; León-González, M E; Pérez-Arribas, L V; Polo-Díez, L M

    2008-01-01

    Chlorophenoxy acid herbicides are intensively applied to get rid of unwanted plants because of their low cost and selectivity. Due to their toxicity, which depends on their chemical form, the European Community has established legal directives to restrict their use and to control their maximum residue levels in several matrices. Determination of chlorophenoxy acids-2,4-dichlorophenoxyacetic acid (2,4-D), 4-chloro-2-methylphenoxyacetic acid (MCPA), 2-(2,4-dichlorophenoxy)propanoic acid (2,4-DP), 2-(4-chloro-2-methylphenoxy)propanoic acid (MCPP), 4-(4-chloro-2-methylphenoxy)butanoic acid (MCPB) and 2-(2,4,5-trichlorophenoxy)propanoic acid (2,4,5-TP) in spiked human urine samples has been carried out by capillary LC, after solid-phase extraction on a column packed with silica C18 restricted-access material. Chromatographic analysis was performed in gradient-elution mode at 25 degrees C, with injection of 20 microL low-organic-solvent composition herbicide solutions for focusing purposes on the head of the capillary column, and diode array detection at 232 nm. Urine samples collected during 24 h from healthy and unexposed volunteers were spiked in the concentration range 25-150 microg L(-1); recoveries obtained were between 66 and 100% (n = 6 for each spiked level) and RSDs (relative standard deviations) were between 1 and 5%. Detection limits in the urine samples from volunteers were between 3.5 and 6.0 microg L(-1). The developed methodology has allowed the clean-up and preconcentration of low volumes of untreated human urine without previous treatment, showing the effectiveness of the employed SPE sorbent for extracting the target analytes and ultimately resulting in the reduction of the sample-preparation time.

  4. Association between a High BK Virus Load in Urine Samples of Patients with Graft-Versus-Host Disease and Development of Hemorrhagic Cystitis after Hematopoietic Stem Cell Transplantation

    PubMed Central

    Bogdanovic, G.; Priftakis, P.; Giraud, G.; Kuzniar, M.; Ferraldeschi, R.; Kokhaei, P.; Mellstedt, H.; Remberger, M.; Ljungman, P.; Winiarski, J.; Dalianis, T.

    2004-01-01

    BK virus (BKV) load in urine alone or in combination with acute graft-versus-host disease (GVHD) was correlated to development of hemorrhagic cystitis (HC). BKV load in combination with acute GVHD discriminated the best, while BKV and viral load alone, but not GVHD, still showed predictive ability for HC. PMID:15528753

  5. Association between a high BK virus load in urine samples of patients with graft-versus-host disease and development of hemorrhagic cystitis after hematopoietic stem cell transplantation.

    PubMed

    Bogdanovic, G; Priftakis, P; Giraud, G; Kuzniar, M; Ferraldeschi, R; Kokhaei, P; Mellstedt, H; Remberger, M; Ljungman, P; Winiarski, J; Dalianis, T

    2004-11-01

    BK virus (BKV) load in urine alone or in combination with acute graft-versus-host disease (GVHD) was correlated to development of hemorrhagic cystitis (HC). BKV load in combination with acute GVHD discriminated the best, while BKV and viral load alone, but not GVHD, still showed predictive ability for HC.

  6. Urine sampling techniques in symptomatic primary-care patients: a diagnostic accuracy review.

    PubMed

    Holm, Anne; Aabenhus, Rune

    2016-06-08

    Choice of urine sampling technique in urinary tract infection may impact diagnostic accuracy and thus lead to possible over- or undertreatment. Currently no evidencebased consensus exists regarding correct sampling technique of urine from women with symptoms of urinary tract infection in primary care. The aim of this study was to determine the accuracy of urine culture from different sampling-techniques in symptomatic non-pregnant women in primary care. A systematic review was conducted by searching Medline and Embase for clinical studies conducted in primary care using a randomized or paired design to compare the result of urine culture obtained with two or more collection techniques in adult, female, non-pregnant patients with symptoms of urinary tract infection. We evaluated quality of the studies and compared accuracy based on dichotomized outcomes. We included seven studies investigating urine sampling technique in 1062 symptomatic patients in primary care. Mid-stream-clean-catch had a positive predictive value of 0.79 to 0.95 and a negative predictive value close to 1 compared to sterile techniques. Two randomized controlled trials found no difference in infection rate between mid-stream-clean-catch, mid-stream-urine and random samples. At present, no evidence suggests that sampling technique affects the accuracy of the microbiological diagnosis in non-pregnant women with symptoms of urinary tract infection in primary care. However, the evidence presented is in-direct and the difference between mid-stream-clean-catch, mid-stream-urine and random samples remains to be investigated in a paired design to verify the present findings.

  7. [Comparison of the Conventional Centrifuged and Filtrated Preparations in Urine Cytology].

    PubMed

    Sekita, Nobuyuki; Shimosakai, Hirofumi; Nishikawa, Rika; Sato, Hiroaki; Kouno, Hiroyoshi; Fujimura, Masaaki; Mikami, Kazuo

    2016-03-01

    The urine cytology test is one of the most important tools for the diagnosis of malignant urinary tract tumors. This test is also of great value for predicting malignancy. However, the sensitivity of this test is not high enough to screen for malignant cells. In our laboratory, we were able to attain a high sensitivity of urine cytology tests after changing the preparation method of urine samples. The differences in the cytodiagnosis between the two methods are discussed here. From January 2012 to June 2013, 2,031 urine samples were prepared using the conventional centrifuge method (C method) ; and from September 2013 to March 2015, 2,453 urine samples were prepared using the filtration method (F method) for the cytology test. When the samples included in category 4 or 5, were defined as cytological positive, the sensitivities of this test with samples prepared using the F method were significantly high compared with samples prepared using the C method (72% vs 28%, p<0.001). The number of cells on the glass slides prepared by the F method was significantly higher than that of the samples prepared by the C method (p<0.001). After introduction of the F method, the number of f alse negative cases was decreased in the urine cytology test because a larger number of cells was seen and easily detected as atypical or malignant epithelial cells. Therefore, this method has a higher sensitivity than the conventional C method as the sensitivity of urine cytology tests relies partially on the number of cells visualized in the prepared samples.

  8. Comparison of urine and bladder or urethral mucosal biopsy culture obtained by transurethral cystoscopy in dogs with chronic lower urinary tract disease: 41 cases (2002 to 2011).

    PubMed

    Sycamore, K F; Poorbaugh, V R; Pullin, S S; Ward, C R

    2014-07-01

    To compare aerobic bacterial culture of urine to cystoscopically obtained mucosal biopsies of the lower urinary tract in dogs. Retrospective review of case records from dogs that had transurethral cystoscopy at a veterinary teaching hospital between 2002 and 2011. Dogs that had culture results from cystocentesis obtained urine and transurethral cystoscopically obtained mucosal samples were included in the study. Pathogens identified were compared between sampling methods. Forty dogs underwent transurethral cystoscopy for lower urinary tract disease on 41 occasions. There was significant (P = 0 · 0003) agreement between urine and mucosal biopsy cultures. Both cultures were negative in 66% and positive in 17% of dogs. There was a 17% disagreement between the sampling methods. Although not statistically significant, more mucosal samples than urine cultures were positive for Escherichia coli. There was a good agreement between pathogen identification from urine and lower urinary tract mucosal cultures. These results do not support the utilisation of transurethral cystoscopy to obtain biopsy samples for culture in dogs with urinary tract infection and positive urine culture. Individual cases with possible chronic urinary tract infection and negative urine culture may benefit from transurethral cystoscopy to obtain biopsies for culture. © 2014 British Small Animal Veterinary Association.

  9. [Delayed testing for the diagnosis of fungi in the urines. Evaluation of the BD Vacutainer C&S tubes for the storage of urine samples at room temperature].

    PubMed

    Baixench, M T; Al-Sheikh, M; Paugam, A

    2005-01-01

    The study included 37 urine samples which have been artificially infected with low levels (10(3) CFU/mL) of various fungi strains. We compared the effects of sample storage, up to 48 hours, at room temperature, in a urine evacuated tube containing specific additives with storage at + 4 degrees C, for the same length of time, in a urine evacuated tube without any additives. There have been no differences of results (speed of growth and colony size) between the 2 modes of storage. However, the experience has shown that samples needed a careful mixing before seeding to avoid underdetection of the strains. Based on the study results, the BD Vacutainer C&S tubes are suitable for delayed testing for the diagnosis of urine fungal infection.

  10. Detection of human papillomavirus DNA in urine. A review of the literature.

    PubMed

    Vorsters, A; Micalessi, I; Bilcke, J; Ieven, M; Bogers, J; Van Damme, P

    2012-05-01

    The detection of human papillomavirus (HPV) DNA in urine, a specimen easily obtained by a non-invasive self-sampling method, has been the subject of a considerable number of studies. This review provides an overview of 41 published studies; assesses how different methods and settings may contribute to the sometimes contradictory outcomes; and discusses the potential relevance of using urine samples in vaccine trials, disease surveillance, epidemiological studies, and specific settings of cervical cancer screening. Urine sampling, storage conditions, sample preparation, DNA extraction, and DNA amplification may all have an important impact on HPV DNA detection and the form of viral DNA that is detected. Possible trends in HPV DNA prevalence in urine could be inferred from the presence of risk factors or the diagnosis of cervical lesions. HPV DNA detection in urine is feasible and may become a useful tool but necessitates further improvement and standardization.

  11. Urine Galactomannan-to-Creatinine Ratio for Detection of Invasive Aspergillosis in Patients with Hematological Malignancies.

    PubMed

    Reischies, Frederike M J; Raggam, Reinhard B; Prattes, Juergen; Krause, Robert; Eigl, Susanne; List, Agnes; Quehenberger, Franz; Strenger, Volker; Wölfler, Albert; Hoenigl, Martin

    2016-03-01

    Galactomannan (GM) testing of urine specimens may provide important advantages, compared to serum testing, such as easy noninvasive sample collection. We evaluated a total of 632 serial urine samples from 71 patients with underlying hematological malignancies and found that the urine GM/creatinine ratio, i.e., (urine GM level × 100)/urine creatinine level, which takes urine dilution into account, reliably detected invasive aspergillosis and may be a promising diagnostic tool for patients with hematological malignancies. (This study has been registered at ClinicalTrials.gov under registration no. NCT01576653.). Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  12. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--METALS IN URINE ANALYTICAL RESULTS

    EPA Science Inventory

    The Metals in Urine data set contains analytical results for measurements of up to 7 metals in 86 urine samples over 86 households. Each sample was collected from the primary respondent within each household. The sample consists of the first morning void following the 24-hour d...

  13. Application of dispersive liquid-liquid microextraction for the preconcentration of eight parabens in real samples and their determination by high-performance liquid chromatography.

    PubMed

    Shen, Xiong; Liang, Jian; Zheng, Luxia; Lv, Qianzhou; Wang, Hong

    2017-11-01

    A simple and sensitive method for the simultaneous determination of eight parabens in human plasma and urine samples was developed. The samples were preconcentrated using dispersive liquid-liquid microextraction based on the solidification of floating organic drops and determined by high-performance liquid chromatography with ultraviolet detection. The influence of variables affecting the extraction efficiency was investigated and optimized using Placket-Burman design and Box-Behnken design. The optimized values were: 58 μL of 1-decanol (as extraction solvent), 0.65 mL methanol (as disperser solvent), 1.5% w/v NaCl in 5.0 mL of sample solution, pH 10.6, and 4.0 min centrifugation at 4000 rpm. The extract was injected into the high-performance liquid chromatography system for analysis. Under the optimum conditions, the linear ranges for eight parabens in plasma and urine were 1.0-1000 ng/mL, with correlation coefficients above 0.994. The limit of detection was 0.2-0.4 and 0.1-0.4 ng/mL for plasma and urine samples, respectively. Relative recoveries were between 80.3 and 110.7%, while relative standard deviations were less than 5.4%. Finally, the method was applied to analyze the parabens in 98 patients of primary breast cancer. Results showed that parabens existed widely, at least one paraben detected in 96.9% (95/98) of plasma samples and 98.0% (96/98) of urine samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Evaluation of Digital PCR as a Technique for Monitoring Acute Rejection in Kidney Transplantation.

    PubMed

    Lee, Hyeseon; Park, Young-Mi; We, Yu-Mee; Han, Duck Jong; Seo, Jung-Woo; Moon, Haena; Lee, Yu-Ho; Kim, Yang-Gyun; Moon, Ju-Young; Lee, Sang-Ho; Lee, Jong-Keuk

    2017-03-01

    Early detection and proper management of kidney rejection are crucial for the long-term health of a transplant recipient. Recipients are normally monitored by serum creatinine measurement and sometimes with graft biopsies. Donor-derived cell-free deoxyribonucleic acid (cfDNA) in the recipient's plasma and/or urine may be a better indicator of acute rejection. We evaluated digital PCR (dPCR) as a system for monitoring graft status using single nucleotide polymorphism (SNP)-based detection of donor DNA in plasma or urine. We compared the detection abilities of the QX200, RainDrop, and QuantStudio 3D dPCR systems. The QX200 was the most accurate and sensitive. Plasma and/or urine samples were isolated from 34 kidney recipients at multiple time points after transplantation, and analyzed by dPCR using the QX200. We found that donor DNA was almost undetectable in plasma DNA samples, whereas a high percentage of donor DNA was measured in urine DNA samples, indicating that urine is a good source of cfDNA for patient monitoring. We found that at least 24% of the highly polymorphic SNPs used to identify individuals could also identify donor cfDNA in transplant patient samples. Our results further showed that autosomal, sex-specific, and mitochondrial SNPs were suitable markers for identifying donor cfDNA. Finally, we found that donor-derived cfDNA measurement by dPCR was not sufficient to predict a patient's clinical condition. Our results indicate that donor-derived cfDNA is not an accurate predictor of kidney status in kidney transplant patients.

  15. Study on color difference estimation method of medicine biochemical analysis

    NASA Astrophysics Data System (ADS)

    Wang, Chunhong; Zhou, Yue; Zhao, Hongxia; Sun, Jiashi; Zhou, Fengkun

    2006-01-01

    The biochemical analysis in medicine is an important inspection and diagnosis method in hospital clinic. The biochemical analysis of urine is one important item. The Urine test paper shows corresponding color with different detection project or different illness degree. The color difference between the standard threshold and the test paper color of urine can be used to judge the illness degree, so that further analysis and diagnosis to urine is gotten. The color is a three-dimensional physical variable concerning psychology, while reflectance is one-dimensional variable; therefore, the estimation method of color difference in urine test can have better precision and facility than the conventional test method with one-dimensional reflectance, it can make an accurate diagnose. The digital camera is easy to take an image of urine test paper and is used to carry out the urine biochemical analysis conveniently. On the experiment, the color image of urine test paper is taken by popular color digital camera and saved in the computer which installs a simple color space conversion (RGB -> XYZ -> L *a *b *)and the calculation software. Test sample is graded according to intelligent detection of quantitative color. The images taken every time were saved in computer, and the whole illness process will be monitored. This method can also use in other medicine biochemical analyses that have relation with color. Experiment result shows that this test method is quick and accurate; it can be used in hospital, calibrating organization and family, so its application prospect is extensive.

  16. Use of a holder-vacuum tube device to save on-site hands in preparing urine samples for head-space gas-chromatography, and its application to determine the time allowance for sample sealing.

    PubMed

    Kawai, Toshio; Sumino, Kimiaki; Ohashi, Fumiko; Ikeda, Masayuki

    2011-01-01

    To facilitate urine sample preparation prior to head-space gas-chromatographic (HS-GC) analysis. Urine samples containing one of the five solvents (acetone, methanol, methyl ethyl ketone, methyl isobutyl ketone and toluene) at the levels of biological exposure limits were aspirated into a vacuum tube via holder, a device commercially available for venous blood collection (the vacuum tube method). The urine sample, 5 ml, was quantitatively transferred to a 20-ml head-space vial prior to HS-GC analysis. The loaded tubes were stored at +4 ℃ in dark for up to 3 d. The vacuum tube method facilitated on-site procedures of urine sample preparation for HS-GC with no significant loss of solvents in the sample and no need of skilled hands, whereas on-site sample preparation time was significantly reduced. Furthermore, no loss of solvents was detected during the 3-d storage, irrespective of hydrophilic (acetone) or lipophilic solvent (toluene). In a pilot application, high performance of the vacuum tube method in sealing a sample in an air-tight space succeeded to confirm that no solvent will be lost when sealing is completed within 5 min after urine voiding, and that the allowance time is as long as 30 min in case of toluene in urine. The use of the holder-vacuum tube device not only saves hands for transfer of the sample to air-tight space, but facilitates sample storage prior to HS-GC analysis.

  17. Effects of storage time and temperature on pH, specific gravity, and crystal formation in urine samples from dogs and cats.

    PubMed

    Albasan, Hasan; Lulich, Jody P; Osborne, Carl A; Lekcharoensuk, Chalermpol; Ulrich, Lisa K; Carpenter, Kathleen A

    2003-01-15

    To determine effects of storage temperature and time on pH and specific gravity of and number and size of crystals in urine samples from dogs and cats. Randomized complete block design. 31 dogs and 8 cats. Aliquots of each urine sample were analyzed within 60 minutes of collection or after storage at room or refrigeration temperatures (20 vs 6 degrees C [68 vs 43 degrees F]) for 6 or 24 hours. Crystals formed in samples from 11 of 39 (28%) animals. Calcium oxalate (CaOx) crystals formed in vitro in samples from 1 cat and 8 dogs. Magnesium ammonium phosphate (MAP) crystals formed in vitro in samples from 2 dogs. Compared with aliquots stored at room temperature, refrigeration increased the number and size of crystals that formed in vitro; however, the increase in number and size of MAP crystals in stored urine samples was not significant. Increased storage time and decreased storage temperature were associated with a significant increase in number of CaOx crystals formed. Greater numbers of crystals formed in urine aliquots stored for 24 hours than in aliquots stored for 6 hours. Storage time and temperature did not have a significant effect on pH or specific gravity. Urine samples should be analyzed within 60 minutes of collection to minimize temperature- and time-dependent effects on in vitro crystal formation. Presence of crystals observed in stored samples should be validated by reevaluation of fresh urine.

  18. Comparison of the Automated cobas u 701 Urine Microscopy and UF-1000i Flow Cytometry Systems and Manual Microscopy in the Examination of Urine Sediments.

    PubMed

    Lee, Wonmok; Ha, Jung-Sook; Ryoo, Nam-Hee

    2016-09-01

    The cobas u 701, a new automated image-based urine sediment analyzer, was introduced recently. In this study, we compared its performance with that of UF-1000i flow cytometry and manual microscopy in the examination of urine sediments. Precision, linearity, and carry-over were determined for the two urine sediment analyzers. For a comparison of the method, 300 urine samples were examined by the automated analyzers and by manual microscopy using a KOVA chamber. Within-run coefficients of variation (CVs) for the control materials were 7.0-8.8% and 1.7-5.7% for the cobas u 701 and UF-1000i systems, respectively. Between-run CVs were 8.5-9.8% and 2.7-5.4%, respectively. Both instruments showed good linearity and negligible carry-over. For red blood cells (RBC), white blood cells (WBC), and epithelial cells (EPI), the overall concordance rates within one grade of difference among the three methods were good (78.6-86.0%, 88.7-93.8%, and 81.3-90.7%, respectively). The concordance rate for casts was poor (66.5-68.9%). Compared with manual microscopy, the two automated sediment analyzers tested in this study showed satisfactory analytical performances for RBC, WBC, and EPI. However, for other urine sediment particles confirmation by visual microscopy is still required. © 2016 Wiley Periodicals, Inc.

  19. Solid phase extraction of 2,4-D from human urine.

    PubMed

    Thompson, T S; Treble, R G

    1996-10-01

    A method for determining urinary concentrations of 2,4-D in samples collected from non-occupationally, environmentally exposed individuals was developed. The 2,4-D was extracted from fortified human urine samples using octadecylsilane solid phase extraction cartridges. The average percent recovery for urine samples spiked at 2 and 20 ng/mL was 100% and 93%, respectively. The method detection limit was estimated to be 0.75 ng of 2,4-D per mL of urine based on a 10 mL sample size. The potential use of 2,4-dichlorophenylacetic acid as a surrogate standard was also investigated.

  20. Quantitative determination of BAF312, a S1P-R modulator, in human urine by LC-MS/MS: prevention and recovery of lost analyte due to container surface adsorption.

    PubMed

    Li, Wenkui; Luo, Suyi; Smith, Harold T; Tse, Francis L S

    2010-02-15

    Analyte loss due to non-specific binding, especially container surface adsorption, is not uncommon in the quantitative analysis of urine samples. In developing a sensitive LC-MS/MS method for the determination of a drug candidate, BAF312, in human urine, a simple procedure was outlined for identification, confirmation and prevention of analyte non-specific binding to a container surface and to recover the 'non-specific loss' of an analyte, if no transfer has occurred to the original urine samples. Non-specific binding or container surface adsorption can be quickly identified by using freshly spiked urine calibration standards and pre-pooled QC samples during a LC-MS/MS feasibility run. The resulting low recovery of an analyte in urine samples can be prevented through the use of additives, such as the non-ionic surfactant Tween-80, CHAPS and others, to the container prior to urine sample collection. If the urine samples have not been transferred from the bulk container, the 'non-specific binding' of an analyte to the container surface can be reversed by the addition of a specified amount of CHAPS, Tween-80 or bovine serum albumin, followed by appropriate mixing. Among the above agents, Tween-80 is the most cost-effective. beta-cyclodextrin may be suitable in stabilizing the analyte of interest in urine via pre-treating the matrix with the agent. However, post-addition of beta-cyclodextrin to untreated urine samples does not recover the 'lost' analyte due to non-specific binding or container surface adsorption. In the case of BAF312, a dynamic range of 0.0200-20.0 ng/ml in human urine was validated with an overall accuracy and precision for QC sample results ranging from -3.2 to 5.1% (bias) and 3.9 to 10.2% (CV), respectively. Pre- and post-addition of 0.5% (v/v) Tween-80 to the container provided excellent overall analyte recovery and minimal MS signal suppression when a liquid-liquid extraction in combination with an isocratic LC separation was employed. The compound was stable in 0.5% Tween-80 treated human urine QC samples for at least 24 h at room temperature, after three freeze/thaw cycles with storage at < or =-60 degrees C and for at least 3 months when stored at < or =-60 degrees C. The current work could serve as a simple example in trouble shooting non-specific binding or container surface adsorption in quantitative analysis of urine samples. Copyright 2010. Published by Elsevier B.V.

  1. Chemical profile analysis and comparison of two versions of the classic TCM formula Danggui Buxue Tang by HPLC-DAD-ESI-IT-TOF-MSn.

    PubMed

    Zhang, Ya-Zhou; Xu, Feng; Yi, Tao; Zhang, Jian-Ye; Xu, Jun; Tang, Yi-Na; He, Xi-Chen; Liu, Jing; Chen, Hu-Biao

    2014-04-30

    Danggui Buxue Tang (DBT) is a Traditional Chinese Medicine (TCM) formula primarily used to treat symptoms associated with menopause in women. Usually, DBT is composed of one portion of Radix Angelicae Sinensis (RAS) and five portions of Radix Astragali (RA). Clinically, Radix Hedysari (RH) is sometimes used by TCM physicians to replace RA in DBT. In order to verity whether the chemical constituents of the DBT1 (RA:RAS = 5:1, w/w) and DBT2 (RH:RAS = 5:1, w/w) share similarities the chemical profiles of the two DBTs crude extracts and urine samples were analyzed and compared with the aid of HPLC-DAD-ESI-IT-TOF-MSn, which determines the total ion chromatogram (TIC) and multi-stage mass spectra (MSn). Then, the DBT1 and DBT2 were identified and compared on the basis of the TIC and the MSn. In the first experiment (with crude extracts), 69 compounds (C1-C69) were identified from the DBT1; 46 compounds (c1-c46) were identified from the DBT2. In the second experiment(with urine samples), 44 compounds (M1-M44) were identified from the urine samples of rats that had been administered DBT1, and 34 compounds (m1-m34) were identified from the urine samples of rats that had been administered DBT2. Identification and comparison of the chemical compositions were carried out between the DBT1 and DBT2 of the crude extracts and urine samples respectively. Our results showed that the two crude extracts of the DBTs have quite different chemical profiles. The reasons for their differences were that the special astragalosides in DBT1 and the isoflavonoid glycosides formed the malonic acid esters undergo single esterification and acetyl esters undergo acetylation in DBT1. In contrast, the urine from DBT1-treated rats strongly resembled that of DBT2-treated rats. These metabolites originate mainly from formononetin, calycosin and their related glycosides, and they were formed mainly by the metabolic process of reduction, deglycosylation, demethylation, hydrogenation and sulfation. The HPLC-DAD-ESI-IT-TOF-MSn method was successfully applied for the rapid chemical profiles evaluation of two DBTs and their related urine samples.

  2. Advances in the Diagnosis of Human Opisthorchiasis: Development of Opisthorchis viverrini Antigen Detection in Urine

    PubMed Central

    Duenngai, Kunyarat; Wangboon, Chompunoot; Sithithaworn, Jiraporn; Watwiengkam, Nattaya; Namwat, Nisana; Techasen, Anchalee; Loilome, Watcharin; Yongvanit, Puangrat; Loukas, Alex; Sithithaworn, Paiboon; Bethony, Jeffrey M.

    2015-01-01

    Background Many strategies to control opisthorchiasis have been employed in Thailand, but not in the other neighbouring countries. Specific control methods include mass drug administration (MDA) and health education to reduce raw fish consumption. These control efforts have greatly shifted the epidemiology of Opisthorchis viverrini (OV) infection over the last decade from presenting as densely concentrated "heavy" infections in single villages to widespread "light" OV infections distributed over wide geographical areas. Currently, the "gold standard" detection method for OV infection is formalin ethyl-acetate concentration technique (FECT), which has limited diagnostic sensitivity and diagnostic specificity for light OV infections, with OV eggs often confused with eggs of minute intestinal flukes (MIFs) in feces. In this study, we developed and evaluated the diagnostic performance of a monoclonal antibody-based enzyme-linked immunosorbent assay for the measurement of OV excretory-secretory (ES) antigens in urine (urine OV-ES assay) for the diagnosis of opisthorchiasis compared to the gold standard detection FECT method. Methodology We tested several methods for pre-treating urine samples prior to testing the diagnostic performance of the urine OV-ES assay. Using trichloroacetic acid (TCA) pre-treated urine, we compared detection and quantification of OV infection using the urine OV-ES assay versus FECT in OV-endemic areas in Northeastern Thailand. Receiver operating characteristic (ROC) curves were used to determine the diagnostic sensitivity and specificity of the urine OV-ES assay using TCA pre-treated urine, and to establish diagnostic positivity thresholds. The Positive Predictive Value as well as the likelihood of obtaining a positive test result (LR+) or a negative test result (LR-) were calculated for the established diagnostic positivity threshold. Diagnostic risks (Odds Ratios) were estimated using logistic regression. Results When urine samples were pre-treated with TCA prior to use in the urine OV-ES assay, the analytical sensitivity was significantly improved. Using TCA pre-treatment of urine, the urine OV-ES assay had a limit of detection (LoD) of 39 ng/ml compared to the LoD of 52 ng/mL reported for coprological antigen detection methods. Similarly, the urine OV-ES assay correlated significantly with intensity of OV infection as measured by FECT. The urine OV-ES assay was also able to detect 28 individuals as positive from the 63 (44.4%) individuals previously determined to be negative using FECT. The likelihood of a positive diagnosis of OV infection by urine OV-ES assay increased significantly with the intensity of OV infection as determined by FECT. With reference to FECT, the sensitivity and specificity of the urine OV-ES assay was 81% and 70%, respectively. Conclusion The detection of OV-infection by the urine OV-ES assay showed much greater diagnostic sensitivity and diagnostic specificity than the current "gold standard" FECT method for the detection and quantification of OV infection. Due to its ease-of-use, and noninvasive sample collection (urine), the urine OV-ES assay offers the potential to revolutionize the diagnosis of liver fluke infection and provide an effective tool for control and elimination of these tumorigenic parasites. PMID:26485024

  3. Testing for nandrolone metabolites in urine samples of professional athletes and sedentary subjects by GC/MS/MS analysis.

    PubMed

    Gambelunghe, Cristiana; Sommavilla, Marco; Rossi, Ruggero

    2002-12-01

    The concentrations of nandrolone metabolites, 19-norandrosterone (19-NA) and 19-noretiocholanolone (19-NE) were analysed in urine samples of professional athletes doing intense physical activity and sedentary subjects to verify if there was endogenous production of nandrolone and if there was any link between physical effort and the urinary metabolites of the steroid. We collected 18 urine samples from professional footballers age range 20-30 years, all from the same team, and 18 urine samples from males not doing any physical activity, age range 20-30 years. Neither group used nandrolone. Qualitative and quantitative analyses of urinary nandrolone metabolites were carried out by GC/MS followed by GC/MS/MS to confirm positive samples. This technique has been demonstrated to be an excellent analytical approach for the determination of anabolic steroids at very low detection limits in complex matrices such as urine. In five urine samples from professional footballers traces of 19-NA were detected. No trace of 19-NA was found in the group of sedentary subjects and no trace of 19-NE was found in any urine sample. The absence of nandrolone metabolites in sedentary subjects supports the hypothesis that the presence of 19-NA and 19-NE could be linked to physical effort even though the origin is not yet clear. Copyright 2002 John Wiley & Sons, Ltd.

  4. Performing a urine dipstick test with a clean-catch urine sample is an accurate screening method for urinary tract infections in young infants.

    PubMed

    Herreros, María Luisa; Tagarro, Alfredo; García-Pose, Araceli; Sánchez, Aida; Cañete, Alfonso; Gili, Pablo

    2018-01-01

    This study evaluated using urine dipstick tests with the clean-catch method to screen for urinary tract infection (UTI) in febrile infants under 90 days of age. We carried out a comparative diagnostic accuracy study of infants under 90 days old, who were studied for unexplained fever without any source, in the emergency room of a hospital in Madrid from January 2011 to January 2013. We obtained matched samples of urine using two different methods: a clean-catch, standardised stimulation technique and catheterisation collection. The results of the leucocyte esterase test and nitrite test were compared with their urine cultures. We obtained 60 pairs of matched samples. A combined analysis of leukocyte esterase and, or, nitrites yielded a sensitivity of 86% and a specificity of 80% for the diagnosis of UTIs in clean-catch samples. The sensitivity of leukocyte esterase and, or, nitrites in samples obtained by catheterisation were not statistically different to the clean-catch samples (p = 0.592). Performing urine dipstick tests using urine samples obtained by the clean-catch method was an accurate screening test for diagnosing UTIs in febrile infants of less than 90 days old. This provided a good alternative to bladder catheterisation when screening for UTIs. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  5. The effect of diet enriched with rapeseed meal on endogenous thiouracil contents in urine and milk of cattle.

    PubMed

    Wozniak, Barbara; Matraszek-Zuchowska, Iwona; Witek, Sebastian; Zmudzki, Jan; Posyniak, Andrzej

    2018-01-15

    Thyreostatic compounds, such as thiouracil, are orally active drugs that can be used to increase the weight of cattle before slaughter. Due to potentially teratogenic and carcinogenic effects of their residues on public health, the use of thyreostats in animal production has been banned in the European Union since 1981. Systematic detection of low concentrations of thiouracil in the urine of livestock in many countries is believed to be of endogenous origin due to the use of Brassicaceae plants in the animal diet. Therefore, the purpose of the study was to determine the effects of diets rich in rapeseed meal on formation of thiouracil in urine and milk of dairy cows. For two weeks three cows were subjected to a diet supplemented with rapeseed at 30%, compared to the control cattle diet which contained up to 11% rapeseed. During the experiment, samples of urine and milk were collected and analysed by LC-MS/MS. The increase and decrease of thiouracil concentration in urine samples in different animals was individual and cyclic. The highest concentration of natural thiouracil determined in urine was 3.61 μg l -1 . It has been found that endogenous thiouracil exists in two tautomeric forms. A few days of storage of frozen urine samples affected the stability of natural thiouracil, whereas an acidic medium improved the stability of the compound and its isomer, which remained stable even after two months of storage at temperatures below -18°C. Due to the instability of thiouracil, urine samples upon sampling should be delivered to the laboratory as soon as possible or properly preserved. In milk samples, thiouracil was not found above the decision limit of the applied method of 0.63 μg l -1 . Preliminary studies have shown that faecal examination for banned thiouracil can be a complementary test for urine samples, and may be helpful in determining the origin of the compound present in urine.

  6. Evaluation of commercial boric acid containing vials for urine culture: low risk of contamination and cost effectiveness considerations.

    PubMed

    Appannanavar, Suma B; Biswal, Manisha; Rajkumari, Nonika; Mohan, Balvinder; Taneja, Neelam

    2013-01-01

    Urine culture is a gold standard in the diagnosis of urinary tract infection. Clean catch midstream urine collection and prompt transportation is essential for appropriate diagnosis. Improper collection and delay in transportation leads to diagnostic dilemma. In developing countries, higher ambient temperatures further complicate the scenario. Here, we have evaluated the role of boric acid as a preservative for urine samples prior to culture in female patients attending outpatient department at our center. Consecutive 104 urine samples were cultured simultaneously in plain uricol (Control-C) and boric acid containing tubes from Becton Dickinson urine culture kit (Boric acid group-BA). In the real-time evaluation, we found that in almost 57% (59/104) of the urine samples tested, it was more effective in maintaining the number of the organisms as compared to samples in the container without any preservative. Our in vitro study of simulated urine cultures revealed that urine samples could be kept up to 12 h before culture in the preservative without any inhibitory effect of boric acid. Though the use of boric acid kit may marginally increase the initial cost but has indirect effects like preventing delays in treatment and avoidance of false prescription of antibiotics. If the man-hours spent on repeat investigations are also taken into consideration, then the economic cost borne by the laboratory would also decrease manifold with the use of these containers.

  7. Variability of Organophosphorous Pesticide Metabolite Levels in Spot and 24-hr Urine Samples Collected from Young Children during 1 Week

    PubMed Central

    Kogut, Katherine; Eisen, Ellen A.; Jewell, Nicholas P.; Quirós-Alcalá, Lesliam; Castorina, Rosemary; Chevrier, Jonathan; Holland, Nina T.; Barr, Dana Boyd; Kavanagh-Baird, Geri; Eskenazi, Brenda

    2012-01-01

    Background: Dialkyl phosphate (DAP) metabolites in spot urine samples are frequently used to characterize children’s exposures to organophosphorous (OP) pesticides. However, variable exposure and short biological half-lives of OP pesticides could result in highly variable measurements, leading to exposure misclassification. Objective: We examined within- and between-child variability in DAP metabolites in urine samples collected during 1 week. Methods: We collected spot urine samples over 7 consecutive days from 25 children (3–6 years of age). On two of the days, we collected 24-hr voids. We assessed the reproducibility of urinary DAP metabolite concentrations and evaluated the sensitivity and specificity of spot urine samples as predictors of high (top 20%) or elevated (top 40%) weekly average DAP metabolite concentrations. Results: Within-child variance exceeded between-child variance by a factor of two to eight, depending on metabolite grouping. Although total DAP concentrations in single spot urine samples were moderately to strongly associated with concentrations in same-day 24-hr samples (r ≈ 0.6–0.8, p < 0.01), concentrations in spot samples collected > 1 day apart and in 24-hr samples collected 3 days apart were weakly correlated (r ≈ –0.21 to 0.38). Single spot samples predicted high (top 20%) and elevated (top 40%) full-week average total DAP excretion with only moderate sensitivity (≈ 0.52 and ≈ 0.67, respectively) but relatively high specificity (≈ 0.88 and ≈ 0.78, respectively). Conclusions: The high variability we observed in children’s DAP metabolite concentrations suggests that single-day urine samples provide only a brief snapshot of exposure. Sensitivity analyses suggest that classification of cumulative OP exposure based on spot samples is prone to type 2 classification errors. PMID:23052012

  8. Advantages of bioconjugated silica-coated nanoparticles as an innovative diagnosis for human toxoplasmosis.

    PubMed

    Aly, Ibrahim; Taher, Eman E; El Nain, Gehan; El Sayed, Hoda; Mohammed, Faten A; Hamad, Rabab S; Bayoumy, Elsayed M

    2018-01-01

    Nanotechnology is a promising arena for generating new applications in Medicine. To successfully functionalised nanoparticles for a given biomedical application, a wide range of chemical, physical and biological factors have to be taken into account. Silica-coated nanoparticles, (SiO2NP) exhibit substantial diagnostic activity owing to their large surface to volume ratios and crystallographic surface structure. This work aimed to evaluate the advantage of bioconjugation of SiO2NP with PAb against Toxoplasma lyzate antigen (TLA) as an innovative diagnostic method for human toxoplasmosis. This cross-sectional study included 120 individuals, divided into Group I: 70 patients suspected for Toxoplasma gondii based on the presence of clinical manifestation. Group II: 30 patients harboring other parasites than T. gondii Group III: 20 apparently healthy individuals free from toxoplasmosis and other parasitic infections served as negative control. Detection of circulating Toxoplasma antigen was performed by Sandwich ELISA and Nano-sandwich ELISA on sera and pooled urine of human samples. Using Sandwich ELISA, 10 out of 70 suspected Toxoplasma-infected human serum samples showed false negative and 8 out of 30 of other parasites groups were false positive giving 85.7% sensitivity and 84.0% specificity, while the sensitivity and specificity were 78.6% and 70% respectively in urine samples. Using Nano-Sandwich ELISA, 7 out of 70 suspected Toxoplasma-infected human samples showed false negative results and the sensitivity of the assay was 90.0%, while 4 out of 30 of other parasites groups were false positive giving 92.0% specificity, while the sensitivity and specificity were 82.6% and 80% respectively in urine samples. In conclusion, our data demonstrated that loading SiO2 nanoparticles with pAb increased the sensitivity and specificity of Nano-sandwich ELISA for detection of T.gondii antigens in serum and urine samples, thus active (early) and light infections could be easily detected. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. COLLECTING URINE SAMPLES FROM YOUNG CHILDREN FOR PESTICIDE STUDIES

    EPA Science Inventory

    To estimate pesticide exposure for young children wearing diapers, a method for collecting urine samples for analysis of pesticide metabolites is needed. To find a practical method, two possibilities were investigated: (1) analysis of expressed urine from cotton diaper inserts ...

  10. Variation in Gas and Volatile Compound Emissions from Human Urine as It Ages, Measured by an Electronic Nose

    PubMed Central

    Esfahani, Siavash; Sagar, Nidhi M.; Kyrou, Ioannis; Mozdiak, Ella; O’Connell, Nicola; Nwokolo, Chuka; Bardhan, Karna D.; Arasaradnam, Ramesh P.; Covington, James A.

    2016-01-01

    The medical profession is becoming ever more interested in the use of gas-phase biomarkers for disease identification and monitoring. This is due in part to its rapid analysis time and low test cost, which makes it attractive for many different clinical arenas. One technology that is showing promise for analyzing these gas-phase biomarkers is the electronic nose—an instrument designed to replicate the biological olfactory system. Of the possible biological media available to “sniff”, urine is becoming ever more important as it is easy to collect and to store for batch testing. However, this raises the question of sample storage shelf-life, even at −80 °C. Here we investigated the effect of storage time (years) on stability and reproducibility of total gas/vapour emissions from urine samples. Urine samples from 87 patients with Type 2 Diabetes Mellitus were collected over a four-year period and stored at −80 °C. These samples were then analyzed using FAIMS (field-asymmetric ion mobility spectrometry—a type of electronic nose). It was discovered that gas emissions (concentration and diversity) reduced over time. However, there was less variation in the initial nine months of storage with greater uniformity and stability of concentrations together with tighter clustering of the total number of chemicals released. This suggests that nine months could be considered a general guide to a sample shelf-life. PMID:26821055

  11. Development and evaluation of an enzyme-linked immunosorbent assay (ELISA) method for the measurement of 2,4-dichlorophenoxyacetic acid in human urine.

    PubMed

    Chuang, Jane C; Emon, Jeanette M Van; Durnford, Joyce; Thomas, Kent

    2005-09-15

    An enzyme-linked immunosorbent assay (ELISA) method was developed to quantitatively measure 2,4-dichlorophenoxyacetic acid (2,4-D) in human urine. Samples were diluted (1:5) with phosphate-buffered saline containing 0.05% Tween and 0.02% sodium azide, with analysis by a 96-microwell plate immunoassay format. No clean up was required as dilution step minimized sample interferences. Fifty urine samples were received without identifiers from a subset of pesticide applicators and their spouses in an EPA pesticide exposure study (PES) and analyzed by the ELISA method and a conventional gas chromatography/mass spectrometry (GC/MS) procedure. For the GC/MS analysis, urine samples were extracted with acidic dichloromethane (DCM); methylated by diazomethane and fractionated by a Florisil solid phase extraction (SPE) column prior to GC/MS detection. The percent relative standard deviation (%R.S.D.) of the 96-microwell plate triplicate assays ranged from 1.2 to 22% for the urine samples. Day-to-day variation of the assay results was within +/-20%. Quantitative recoveries (>70%) of 2,4-D were obtained for the spiked urine samples by the ELISA method. Quantitative recoveries (>80%) of 2,4-D were also obtained for these samples by the GC/MS procedure. The overall method precision of these samples was within +/-20% for both the ELISA and GC/MS methods. The estimated quantification limit for 2,4-D in urine was 30ng/mL by ELISA and 0.2ng/mL by GC/MS. A higher quantification limit for the ELISA method is partly due to the requirement of a 1:5 dilution to remove the urine sample matrix effect. The GC/MS method can accommodate a 10:1 concentration factor (10mL of urine converted into 1mL organic solvent for analysis) but requires extraction, methylation and clean up on a solid phase column. The immunoassay and GC/MS data were highly correlated, with a correlation coefficient of 0.94 and a slope of 1.00. Favorable results between the two methods were achieved despite the vast differences in sample preparation. Results indicated that the ELISA method could be used as a high throughput, quantitative monitoring tool for human urine samples to identify individuals with exposure to 2,4-D above the typical background levels.

  12. Quantitative determination of metformin, glyburide and its metabolites in plasma and urine of pregnant patients by LC-MS/MS.

    PubMed

    Zhang, Xing; Wang, Xiaoming; Vernikovskaya, Daria I; Fokina, Valentina M; Nanovskaya, Tatiana N; Hankins, Gary D V; Ahmed, Mahmoud S

    2015-04-01

    This report describes the development and validation of an LC-MS/MS method for the quantitative determination of glyburide (GLB), its five metabolites (M1, M2a, M2b, M3 and M4) and metformin (MET) in plasma and urine of pregnant patients under treatment with a combination of the two medications. The extraction recovery of the analytes from plasma samples was 87-99%, and that from urine samples was 85-95%. The differences in retention times among the analytes and the wide range of the concentrations of the medications and their metabolites in plasma and urine patient samples required the development of three LC methods. The lower limit of quantitation (LLOQ) of the analytes in plasma samples was as follows: GLB, 1.02 ng/mL; its five metabolites, 0.100-0.113 ng/mL; and MET, 4.95 ng/mL. The LLOQ in urine samples was 0.0594 ng/mL for GLB, 0.984-1.02 ng/mL for its five metabolites and 30.0 µg/mL for MET. The relative deviation of this method was <14% for intra-day and inter-day assays in plasma and urine samples, and the accuracy was 86-114% in plasma, and 94-105% in urine. The method described in this report was successfully utilized for determining the concentrations of the two medications in patient plasma and urine. Copyright © 2014 John Wiley & Sons, Ltd.

  13. Quantitative determination of metformin, glyburide and its metabolites in plasma and urine of pregnant patients by LC-MS/MS

    PubMed Central

    Zhang, Xing; Wang, Xiaoming; Vernikovskaya, Daria I.; Fokina, Valentina M.; Nanovskaya, Tatiana N.; Hankins, Gary D.V.; Ahmed, Mahmoud S.

    2014-01-01

    This report describes the development and validation of an LC-MS/MS method for the quantitative determination of glyburide (GLB), its five metabolites (M1, M2a, M2b, M3, and M4) and metformin (MET) in plasma and urine of pregnant patients under treatment with a combination of the two medications. The extraction recovery of the analytes from plasma samples ranged between 87% and 99%, and 85%–95% for urine samples. The differences in retention times among the analytes, and the wide range of the concentrations of the medications and their metabolites in plasma and urine patient samples required the development of three LC methods. The lower limit of quantitation (LLOQ) of the analytes in plasma samples was as follows: GLB, 1.02 ng/mL; its five metabolites, 0.100–0.113 ng/mL and 4.95 ng/mL for MET. LLOQ in urine samples was 0.0594 ng/mL for GLB, 0.984–1.02 ng/mL for its five metabolites and 30.0 μg/mL for MET. The relative deviation of this method was < 14% for intra-day and inter-day assays in plasma and urine samples, and the accuracy ranged between 86% and 114% in plasma, and 94% to 105% in urine. The method described in this report was successfully utilized for determining the concentrations of the two medications in patient plasma and urine. PMID:25164921

  14. Urine stability studies for novel biomarkers of acute kidney injury.

    PubMed

    Parikh, Chirag R; Butrymowicz, Isabel; Yu, Angela; Chinchilli, Vernon M; Park, Meyeon; Hsu, Chi-Yuan; Reeves, W Brian; Devarajan, Prasad; Kimmel, Paul L; Siew, Edward D; Liu, Kathleen D

    2014-04-01

    The study of novel urinary biomarkers of acute kidney injury has expanded exponentially. Effective interpretation of data and meaningful comparisons between studies require awareness of factors that can adversely affect measurement. We examined how variations in short-term storage and processing might affect the measurement of urine biomarkers. Cross-sectional prospective. Hospitalized patients from 2 sites: Yale New Haven Hospital (n=50) and University of California, San Francisco Medical Center (n=36). We tested the impact of 3 urine processing conditions on these biomarkers: (1) centrifugation and storage at 4°C for 48 hours before freezing at -80°C, (2) centrifugation and storage at 25°C for 48 hours before freezing at -80°C, and (3) uncentrifuged samples immediately frozen at -80°C. Urine concentrations of 5 biomarkers: neutrophil gelatinase-associated lipocalin (NGAL), interleukin 18 (IL-18), kidney injury molecule 1 (KIM-1), liver-type fatty acid-binding protein (L-FABP), and cystatin C. We measured urine biomarkers by established enzyme-linked immunosorbent assay methods. Biomarker values were log-transformed, and agreement with a reference standard of immediate centrifugation and storage at -80°C was compared using concordance correlation coefficients (CCCs). Neither storing samples at 4°C for 48 hours nor centrifugation had a significant effect on measured levels, with CCCs higher than 0.9 for all biomarkers tested. For samples stored at 25°C for 48 hours, excellent CCC values (>0.9) also were noted between the test sample and the reference standard for NGAL, cystatin C, L-FABP and KIM-1. However, the CCC for IL-18 between samples stored at 25°C for 48 hours and the reference standard was 0.81 (95% CI, 0.66-0.96). No comparisons to fresh, unfrozen samples; no evaluation of the effect of protease inhibitors. All candidate markers tested using the specified assays showed high stability with both short-term storage at 4°C and without centrifugation prior to freezing. For optimal fidelity, urine for IL-18 measurement should not be stored at 25°C before long-term storage or analysis. Copyright © 2014 National Kidney Foundation, Inc. All rights reserved.

  15. A novel way to monitor urine concentration: fluorescent concentration matrices.

    PubMed

    Dubayova, Katarina; Luckova, Iveta; Sabo, Jan; Karabinos, Anton

    2015-01-01

    The amount of water found in urine is important diagnostic information; nevertheless it is not yet directly determined. Indirectly, the water content in urine is expressed by its density (specific gravity). However, without the diuresis value it is not possible to determine whether the increase in density of urine is due to a decrease in water secretion or an increase in the concentration of secreted substances. This problem can be solved by the use of fluorescent concentration 3D-matrices which characterise urine concentration through the pφ (or -logφ) value of the first fluorescence centre. The urine fluorescent concentration 3D-matrix was created by the alignment of the synchronous spectra of the dilution series of urine starting from undiluted (pφ = 0) to 1000-fold diluted urine (pφ = 3). Using the fluorescence concentration 3D-matrix analysis of the urine samples from healthy individuals, a reference range was established for the value pφ, determining the normal, concentrated or diluted type of urine. The diagnostic potential of this approach was tested on urine samples from two patients with a chronic glomerulonephritis. The pφ value of the urine fluorescence concentration 3D-matrix analysis determines whether the urine sample falls within the normal, concentrated or diluted type of urine. This parameter can be directly utilised in sportsmen's hydration state monitoring, as well as in the diagnosis and treatment of serious diseases. An important advantage of this novel diagnostic approach is that a 12/24 h urine collection is not required, which predetermines it for use especially within paediatrics.

  16. An optical spot test for the detection of dopamine in human urine using stabilized in air lipid films.

    PubMed

    Nikolelis, Dimitrios P; Drivelos, Dimitrios A; Simantiraki, Maria G; Koinis, Spyros

    2004-04-15

    The present technique describes a simple, sensitive spot test for the rapid one-shot detection of dopamine in human urine using lipid films with incorporated resorcin[4]arene receptor that are synthesized by a chemical reaction with a methacrylate polymer on a glass fiber filter. The lipid films without the receptor provided fluorescence under a UV lamp. The use of the receptor in these films quenched this fluorescence, and the color became similar to that of the filters without the lipid films. A drop of dopamine or urine containing this stimulant provided a "switching on" of the fluorescence, which allows the rapid detection of this stimulant in human urine at 10(-8) M concentrations. The novelty of the present work is that it opens new routes in the field of biosensing, i.e., development of sensitive, rapid, and simple methods for detecting species based on the fluorescence of the lipid membranes on a polymer film, and provides a spot test technique for the rapid detection of dopamine. The effect of potent interferences including a wide range of compounds usually found in human urine (i.e., ascorbic aid, glucose, leucine, glycine, tartrate, citrate, bicarbonate, and caffeine) was examined using an aqueous buffered solution that contained the potent interference and dopamine at two lower concentration levels (i.e., 3 x 10(-8)-10(-8) M). The effect of proteins and lipids was also investigated at these two lower dopamine concentration levels in aqueous buffered solution. The results showed no interferences from all these constituents at concentrations usually found in human urine samples; for example, albumin up to 3.22 g/L concentration levels did not provide any interference (i.e., no fluorescence). A drop of urine containing this stimulant provided similar results, i.e., a "switching on" of the fluorescence that allows a technique for the rapid detection of this stimulant in human urine at 10(-8) M concentrations. The technique is not based on a calibration graph but is a semiquantitative method for the detection of dopamine in real samples of urine that can be complimentary to HPLC methods. The difference in color between the samples containing dopamine at concentration levels of 10(-8)-10(-7) M can be easily distinguished by naked eye and a digital camera. An increase of dopamine concentration from 10(-8) to 10(-7) M makes the color more blue whereas the color of the filters remains purple in the blank test (i.e., addition of a urine sample without dopamine or dopamine at concentration levels of 10(-9) M to the filters that contain the lipid membranes with incorporated receptor). The reproducibility of the method was checked in approximately 100 samples, and all of them were found to provide similar results. Note that it was also found that the colors remain stable in the samples containing dopamine for periods of more than two months.

  17. Accuracy of recommended sampling and assay methods for the determination of plasma-free and urinary fractionated metanephrines in the diagnosis of pheochromocytoma and paraganglioma: a systematic review.

    PubMed

    Därr, Roland; Kuhn, Matthias; Bode, Christoph; Bornstein, Stefan R; Pacak, Karel; Lenders, Jacques W M; Eisenhofer, Graeme

    2017-06-01

    To determine the accuracy of biochemical tests for the diagnosis of pheochromocytoma and paraganglioma. A search of the PubMed database was conducted for English-language articles published between October 1958 and December 2016 on the biochemical diagnosis of pheochromocytoma and paraganglioma using immunoassay methods or high-performance liquid chromatography with coulometric/electrochemical or tandem mass spectrometric detection for measurement of fractionated metanephrines in 24-h urine collections or plasma-free metanephrines obtained under seated or supine blood sampling conditions. Application of the Standards for Reporting of Diagnostic Studies Accuracy Group criteria yielded 23 suitable articles. Summary receiver operating characteristic analysis revealed sensitivities/specificities of 94/93% and 91/93% for measurement of plasma-free metanephrines and urinary fractionated metanephrines using high-performance liquid chromatography or immunoassay methods, respectively. Partial areas under the curve were 0.947 vs. 0.911. Irrespective of the analytical method, sensitivity was significantly higher for supine compared with seated sampling, 95 vs. 89% (p < 0.02), while specificity was significantly higher for supine sampling compared with 24-h urine, 95 vs. 90% (p < 0.03). Partial areas under the curve were 0.942, 0.913, and 0.932 for supine sampling, seated sampling, and urine. Test accuracy increased linearly from 90 to 93% for 24-h urine at prevalence rates of 0.0-1.0, decreased linearly from 94 to 89% for seated sampling and was constant at 95% for supine conditions. Current tests for the biochemical diagnosis of pheochromocytoma and paraganglioma show excellent diagnostic accuracy. Supine sampling conditions and measurement of plasma-free metanephrines using high-performance liquid chromatography with coulometric/electrochemical or tandem mass spectrometric detection provides the highest accuracy at all prevalence rates.

  18. Suitability of bovine bile compared to urine for detection of free, sulfate and glucuronate boldenone, androstadienedione, cortisol, cortisone, prednisolone, prednisone and dexamethasone by LC-MS/MS.

    PubMed

    Chiesa, Luca; Nobile, Maria; Panseri, Sara; Vigo, Daniele; Pavlovic, Radmila; Arioli, Francesco

    2015-12-01

    The administration of boldenone and androstadienedione to cattle is forbidden in the European Union, while prednisolone is permitted for therapeutic purposes. They are pseudoendogenous substances (endogenously produced under certain circumstances). The commonly used matrices in control analyses are urine or liver. With the aim of improving the residue controls, we previously validated a method for steroid analysis in bile. We now compare urine (a 'classic' matrix) to bile, both collected at the slaughterhouse, to understand whether the detection of steroids in the latter is easier. With the aim of having clearer results, we tested the presence of the synthetic corticosteroid dexamethasone. The results show that bile does not substantially improve the detection of boldenone, or its conjugates, prednisolone and prednisone. Dexamethasone, instead, was found in 10 out of 53 bovine bile samples, but only in one urine sample from the same animals. Bile could constitute a novel matrix for the analysis of residues in food-producing animals, and possibly not only of synthetic corticosteroids. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Trimethylamine and trimethylamine oxide levels in normal women and women with bacterial vaginosis reflect a local metabolism in vaginal secretion as compared to urine.

    PubMed

    Wolrath, H; Ståhlbom, B; Hallén, A; Forsum, U

    2005-01-01

    The smell of rotten fish is one of the characteristics of bacterial vaginosis (BV), and is due to trimethylamine (TMA). Trimethylamine can be found in human urine, although most of it occurs as the nonvolatile oxide (TMAO) form. The fraction TMA/TMAO can be expected to be the same in different body fluids if no local production of TMA occurs. In women with BV, TMAO in the vaginal fluid is expected to be chemically reduced by the local bacterial flora to the much more odorous TMA. We have therefore studied the local vaginal production of TMA in vaginal secretion compared to the general TMA-TMAO metabolism that was measured in urine using gas chromatography. Both vaginal fluid and random urine samples were collected from women, with and without BV, attending a Swedish clinic for sexually transmitted diseases, and these samples were analyzed for TMA and TMAO. The results show that a local production of TMA occurs in the vagina that is not part of the general metabolism of TMA-TMAO.

  20. Improved sensitivity of the urine CAA lateral-flow assay for diagnosing active Schistosoma infections by using larger sample volumes.

    PubMed

    Corstjens, Paul L A M; Nyakundi, Ruth K; de Dood, Claudia J; Kariuki, Thomas M; Ochola, Elizabeth A; Karanja, Diana M S; Mwinzi, Pauline N M; van Dam, Govert J

    2015-04-22

    Accurate determination of Schistosoma infection rates in low endemic regions to examine progress towards interruption of transmission and elimination requires highly sensitive diagnostic tools. An existing lateral flow (LF) based test demonstrating ongoing infections through detection of worm circulating anodic antigen (CAA), was improved for sensitivity through implementation of a protocol allowing increased sample input. Urine is the preferred sample as collection is non-invasive and sample volume is generally not a restriction. Centrifugal filtration devices provided a method to concentrate supernatant of urine samples extracted with trichloroacetic acid (TCA). For field trials a practical sample volume of 2 mL urine allowed detection of CAA down to 0.3 pg/mL. The method was evaluated on a set of urine samples (n = 113) from an S. mansoni endemic region (Kisumu, Kenya) and compared to stool microscopy (Kato Katz, KK). In this analysis true positivity was defined as a sample with either a positive KK or UCAA test. Implementation of the concentration method increased clinical sensitivity (Sn) from 44 to 98% when moving from the standard 10 μL (UCAA10 assay) to 2000 μL (UCAA2000 assay) urine sample input. Sn for KK varied between 23 and 35% for a duplicate KK (single stool, two slides) to 52% for a six-fold KK (three consecutive day stools, two slides). The UCAA2000 assay indicated 47 positive samples with CAA concentration above 0.3 pg/mL. The six-fold KK detected 25 egg positives; 1 sample with 2 eggs detected in the 6-fold KK was not identified with the UCAA2000 assay. Larger sample input increased Sn of the UCAA assay to a level indicating 'true' infection. Only a single 2 mL urine sample is needed, but analysing larger sample volumes could still increase test accuracy. The UCAA2000 test is an appropriate candidate for accurate identification of all infected individuals in low-endemic regions. Assay materials do not require refrigeration and collected urine samples may be stored and transported to central test laboratories without the need to be frozen.

  1. Formal recycling of e-waste leads to increased exposure to toxic metals: an occupational exposure study from Sweden.

    PubMed

    Julander, Anneli; Lundgren, Lennart; Skare, Lizbet; Grandér, Margaretha; Palm, Brita; Vahter, Marie; Lidén, Carola

    2014-12-01

    Electrical and electronic waste (e-waste) contains multiple toxic metals. However, there is currently a lack of exposure data for metals on workers in formal recycling plants. The objective of this study was to evaluate workers' exposure to metals, using biomarkers of exposure in combination with monitoring of personal air exposure. We assessed exposure to 20 potentially toxic metals among 55 recycling workers and 10 office workers at three formal e-waste recycling plants in Sweden. Workers at two of the plants were followed-up after 6 months. We collected the inhalable fraction and OFC (37-mm) fraction of particles, using personal samplers, as well as spot samples of blood and urine. We measured metal concentrations in whole blood, plasma, urine, and air filters using inductively coupled plasma-mass spectrometry following acid digestion. The air sampling indicated greater airborne exposure, 10 to 30 times higher, to most metals among the recycling workers handling e-waste than among the office workers. The exposure biomarkers showed significantly higher concentrations of chromium, cobalt, indium, lead, and mercury in blood, urine, and/or plasma of the recycling workers, compared with the office workers. Concentrations of antimony, indium, lead, mercury, and vanadium showed close to linear associations between the inhalable particle fraction and blood, plasma, or urine. In conclusion, our study of formal e-waste recycling shows that workers performing recycling tasks are exposed to multiple toxic metals. Copyright © 2014. Published by Elsevier Ltd.

  2. The Rapid-Heat LAMPellet Method: A Potential Diagnostic Method for Human Urogenital Schistosomiasis

    PubMed Central

    Carranza-Rodríguez, Cristina; Pérez-Arellano, José Luis; Vicente, Belén; López-Abán, Julio; Muro, Antonio

    2015-01-01

    Background Urogenital schistosomiasis due to Schistosoma haematobium is a serious underestimated public health problem affecting 112 million people - particularly in sub-Saharan Africa. Microscopic examination of urine samples to detect parasite eggs still remains as definitive diagnosis. This work was focussed on developing a novel loop-mediated isothermal amplification (LAMP) assay for detection of S. haematobium DNA in human urine samples as a high-throughput, simple, accurate and affordable diagnostic tool to use in diagnosis of urogenital schistosomiasis. Methodology/Principal Findings A LAMP assay targeting a species specific sequence of S. haematobium ribosomal intergenic spacer was designed. The effectiveness of our LAMP was assessed in a number of patients´ urine samples with microscopy confirmed S. haematobium infection. For potentially large-scale application in field conditions, different DNA extraction methods, including a commercial kit, a modified NaOH extraction method and a rapid heating method were tested using small volumes of urine fractions (whole urine, supernatants and pellets). The heating of pellets from clinical samples was the most efficient method to obtain good-quality DNA detectable by LAMP. The detection limit of our LAMP was 1 fg/µL of S. haematobium DNA in urine samples. When testing all patients´ urine samples included in our study, diagnostic parameters for sensitivity and specificity were calculated for LAMP assay, 100% sensitivity (95% CI: 81.32%-100%) and 86.67% specificity (95% CI: 75.40%-94.05%), and also for microscopy detection of eggs in urine samples, 69.23% sensitivity (95% CI: 48.21% -85.63%) and 100% specificity (95% CI: 93.08%-100%). Conclusions/Significance We have developed and evaluated, for the first time, a LAMP assay for detection of S. haematobium DNA in heated pellets from patients´ urine samples using no complicated requirement procedure for DNA extraction. The procedure has been named the Rapid-Heat LAMPellet method and has the potential to be developed further as a field diagnostic tool for use in urogenital schistosomiasis-endemic areas. PMID:26230990

  3. Using dispersive liquid-liquid microextraction and liquid chromatography for determination of guaifenesin enantiomers in human urine.

    PubMed

    Hatami, Mehdi; Farhadi, Khalil; Abdollahpour, Assem

    2011-11-01

    A simple, rapid, and efficient method, dispersive liquid-liquid microextraction (DLLME) coupled with high-performance liquid chromatography-fluorescence detector, has been developed for the determination of guaifenesin (GUA) enantiomers in human urine samples after an oral dose administration of its syrup formulation. Urine samples were collected during the time intervals 0-2, 2-4, and 4-6 h and concentration and ratio of two enantiomers was determined. The ratio of R-(-) to S-(+) enantiomer concentrations in urine showed an increase with time, with R/S ratios of 0.66 at 2 h and 2.23 at 6 h. For microextraction process, a mixture of extraction solvent (dichloromethane, 100 μL) and dispersive solvent (THF, 1 mL) was rapidly injected into 5.0 mL diluted urine sample for the formation of cloudy solution and extraction of enantiomers into the fine droplets of CH(2)Cl(2). After optimization of HPLC enantioselective conditions, some important parameters, such as the kind and volume of extraction and dispersive solvents, extraction time, temperature, pH, and salt effect were optimized for dispersive liquid-liquid microextraction process. Under the optimum extraction condition, the method yields a linear calibration curve in the concentration range from 10 to 2000 ng/mL for target analytes. LOD was 3.00 ng/mL for both of the enantiomers. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. A validated solid-phase extraction HPLC method for the simultaneous determination of the citrus flavanone aglycones hesperetin and naringenin in urine.

    PubMed

    Kanaze, Feras Imad; Kokkalou, Eugene; Georgarakis, Manolis; Niopas, Ioannis

    2004-09-21

    A simple, specific, precise, accurate, and robust HPLC assay for the simultaneous analysis of hesperetin and naringenin in human urine was developed and validated. Urine samples were incubated with beta-glucuronidase/sulphatase and the analytes were isolated by solid-phase extraction using C18 cartridges and separated on a C8 reversed phase column using a mixture of methanol/water/acetic acid (40:58:2, v/v/v) at 45 degrees C. The method was found to be linear in the 50-1200 ng/ml concentration range for both hesperetin and naringenin (r > 0.999). The accuracy of the method was greater than 94.8%, while the intra- and inter-day precision for hesperetin was better than 4.9 and 8.2%, respectively and for naringenin was better than 5.3 and 7.8%, respectively. Recovery for hesperetin, naringenin and internal standard 7-ethoxycoumarin was greater than 70.9%. The method has been applied for the determination of hesperetin and naringenin in urine samples obtained from a male volunteer following a single 300 mg oral dose of each of the corresponding flavanone glycosides hesperidin and naringin. The intra- and inter-day reproducibility through enzyme hydrolysis was less than 3.9% for both total (free + conjugated) hesperetin and naringenin. Stability studies showed urine quality control samples to be stable for both hesperetin and naringenin through three freeze-thaw cycles and at room temperature for 24 h (error < or = 3.6%).

  5. Estimating population salt intake in India using spot urine samples.

    PubMed

    Petersen, Kristina S; Johnson, Claire; Mohan, Sailesh; Rogers, Kris; Shivashankar, Roopa; Thout, Sudhir Raj; Gupta, Priti; He, Feng J; MacGregor, Graham A; Webster, Jacqui; Santos, Joseph Alvin; Krishnan, Anand; Maulik, Pallab K; Reddy, K Srinath; Gupta, Ruby; Prabhakaran, Dorairaj; Neal, Bruce

    2017-11-01

    To compare estimates of mean population salt intake in North and South India derived from spot urine samples versus 24-h urine collections. In a cross-sectional survey, participants were sampled from slum, urban and rural communities in North and in South India. Participants provided 24-h urine collections, and random morning spot urine samples. Salt intake was estimated from the spot urine samples using a series of established estimating equations. Salt intake data from the 24-h urine collections and spot urine equations were weighted to provide estimates of salt intake for Delhi and Haryana, and Andhra Pradesh. A total of 957 individuals provided a complete 24-h urine collection and a spot urine sample. Weighted mean salt intake based on the 24-h urine collection, was 8.59 (95% confidence interval 7.73-9.45) and 9.46 g/day (8.95-9.96) in Delhi and Haryana, and Andhra Pradesh, respectively. Corresponding estimates based on the Tanaka equation [9.04 (8.63-9.45) and 9.79 g/day (9.62-9.96) for Delhi and Haryana, and Andhra Pradesh, respectively], the Mage equation [8.80 (7.67-9.94) and 10.19 g/day (95% CI 9.59-10.79)], the INTERSALT equation [7.99 (7.61-8.37) and 8.64 g/day (8.04-9.23)] and the INTERSALT equation with potassium [8.13 (7.74-8.52) and 8.81 g/day (8.16-9.46)] were all within 1 g/day of the estimate based upon 24-h collections. For the Toft equation, estimates were 1-2 g/day higher [9.94 (9.24-10.64) and 10.69 g/day (9.44-11.93)] and for the Kawasaki equation they were 3-4 g/day higher [12.14 (11.30-12.97) and 13.64 g/day (13.15-14.12)]. In urban and rural areas in North and South India, most spot urine-based equations provided reasonable estimates of mean population salt intake. Equations that did not provide good estimates may have failed because specimen collection was not aligned with the original method.

  6. Clinical utility of capillary polymerase chain reaction for diagnosis of Cytomegalovirus pneumonia.

    PubMed

    Honda, J; Yonemitsu, J; Kitajima, H; Yosida, N; Fumirori, T; Oizumi, K

    2001-01-01

    The purpose of this retrospective study was to assess the diagnostic efficacy of CMV DNA detection by capillary PCR in patients with interstitial pneumonia. Of 882 samples taken from 363 patients, 317 were obtained from sputum, 94 from BAL fluid, 291 from blood and 180 from urine. PCR for CMV was positive in 58 samples (6.6%), with positive detection for 6.9% of sputum, 10.6% of BAL fluid, 4.1% of blood and 7.8% of urine samples. CMV pneumonia was diagnosed retrospectively in 34 (9.4%) of the 363 patients by demonstration of CMV antigen-positive cytomegalic inclusion bodies in lung tissue sections. The positive and negative predictive values were 100% (10/10) and 98.8% (83/84) for the BAL fluid samples and 95.5% (21/22) and 99.7% (294/295) for the sputum samples, respectively. Clinical sensitivity and specificity were 90.9% (10/11) and 100% (83/83) for the BAL fluid samples and 95.5% (21/22) and 99.7% (294/295) for the sputum samples, respectively. However, the blood and urine samples showed poor clinical sensitivity and low positive predictive values. We suggest that the use of capillary PCR for BAL fluid and sputum samples is very useful for diagnosing CMV pneumonia in patients with interstitial pneumonia in whom CMV pneumonia is suspected.

  7. Simple DNA extraction of urine samples: Effects of storage temperature and storage time.

    PubMed

    Ng, Huey Hian; Ang, Hwee Chen; Hoe, See Ying; Lim, Mae-Lynn; Tai, Hua Eng; Soh, Richard Choon Hock; Syn, Christopher Kiu-Choong

    2018-06-01

    Urine samples are commonly analysed in cases with suspected illicit drug consumption. In events of alleged sample mishandling, urine sample source identification may be necessary. A simple DNA extraction procedure suitable for STR typing of urine samples was established on the Promega Maxwell ® 16 paramagnetic silica bead platform. A small sample volume of 1.7mL was used. Samples were stored at room temperature, 4°C and -20°C for 100days to investigate the influence of storage temperature and time on extracted DNA quantity and success rate of STR typing. Samples stored at room temperature exhibited a faster decline in DNA yield with time and lower typing success rates as compared to those at 4°C and -20°C. This trend can likely be attributed to DNA degradation. In conclusion, this study presents a quick and effective DNA extraction protocol from a small urine volume stored for up to 100days at 4°C and -20°C. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Exploring the concurrent presence of hepatitis A virus genome in serum, stool, saliva, and urine samples of hepatitis A patients.

    PubMed

    Joshi, Madhuri S; Bhalla, Shilpa; Kalrao, Vijay R; Dhongade, Ramchandra K; Chitambar, Shobha D

    2014-04-01

    The use of saliva and urine as an alternative to serum samples for detection of anti-hepatitis A virus (HAV) IgM antibodies has been documented. However, these samples remain underreported or unexplored for shedding of HAV. To address this issue, paired serum, stool, saliva, and urine samples collected from hepatitis A patients were screened by reverse transcription polymerase chain reaction for detection of HAV RNA. HAV RNA was detected in 67.6% (44/65), 52.3% (34/65), 8.7% (5/57), and 12.3% (8/65) of the serum, stool, saliva, and urine samples, respectively. Phylogenetic analysis of nucleotide sequences obtained for partial RNA polymerase region grouped HAV strains from all of the clinical samples of the study in subgenotype IIIA. Low frequency of HAV nucleic acid in saliva and urine samples indicates limited utility of these samples in genomic studies on HAV but suggests its potential for transmission and infection of hepatitis A. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Rapid Diagnosis of Ethylene Glycol Poisoning by Urine Microscopy.

    PubMed

    Sheta, Hussam Mahmoud; Al-Najami, Issam; Christensen, Heidi Dahl; Madsen, Jonna Skov

    2018-06-14

    BACKGROUND Ethylene glycol poisoning remains an important presentation to Emergency Departments. Quick diagnosis and treatment are essential to prevent renal failure and life-threating complications. CASE REPORT In this case report, we present a patient who was admitted unconscious to the hospital. Ethylene glycol poisoning was immediately suspected, because the patient had previously been hospitalized with similar symptoms after intake of antifreeze coolant. A urine sample was sent for microscopy and showed multiple calcium oxalate monohydrate (COM) crystals, which supported the clinical suspicion of ethylene glycol poisoning. The patient was treated with continuous intravenous ethyl alcohol infusion and hemodialysis. Two days after admission, the patient was awake and in clinical recovery. CONCLUSIONS Demonstration of COM crystals using microscopy of a urine sample adds valuable information supporting the clinical suspicion of ethylene glycol poisoning, and may serve as an easy, quick, and cheap method that can be performed in any emergency setting.

  10. Urinalysis: MedlinePlus Health Topic

    MedlinePlus

    ... Urine odor (Medical Encyclopedia) Also in Spanish Urine pH test (Medical Encyclopedia) Also in Spanish Urine specific gravity ... Urine - abnormal color Urine - bloody Urine odor Urine pH test Urine specific gravity test Show More Show Less ...

  11. Sulphur tracer experiments in laboratory animals using 34S-labelled yeast.

    PubMed

    Martínez-Sierra, J Giner; Moreno Sanz, F; Herrero Espílez, P; Marchante Gayón, J M; Rodríguez Fernández, J; García Alonso, J I

    2013-03-01

    We have evaluated the use of (34)S-labelled yeast to perform sulphur metabolic tracer experiments in laboratory animals. The proof of principle work included the selection of the culture conditions for the preparation of sulphur labelled yeast, the study of the suitability of this labelled yeast as sulphur source for tracer studies using in vitro gastrointestinal digestion and the administration of the (34)S-labelled yeast to laboratory animals to follow the fate and distribution of (34)S in the organism. For in vitro gastrointestinal digestion, the combination of sodium dodecyl sulphate-polyacrylamide gel electrophoresis and high-performance liquid chromatography and inductively coupled plasma mass spectrometry (HPLC-ICP-MS) showed that labelled methionine, cysteine and other low molecular weight sulphur-containing biomolecules were the major components in the digested extracts of the labelled yeast. Next, in vivo kinetic experiments were performed in healthy Wistar rats after the oral administration of (34)S-labelled yeast. The isotopic composition of total sulphur in tissues, urine and faeces was measured by double-focusing inductively coupled plasma mass spectrometry after microwave digestion. It was observed that measurable isotopic enrichments were detected in all samples. Finally, initial investigations on sulphur isotopic composition of serum and urine samples by HPLC-ICP-MS have been carried out. For serum samples, no conclusive data were obtained. Interestingly, chromatographic analysis of urine samples showed differential isotope enrichment for several sulphur-containing biomolecules.

  12. A magnetic bead-based method for concentrating DNA from human urine for downstream detection.

    PubMed

    Bordelon, Hali; Russ, Patricia K; Wright, David W; Haselton, Frederick R

    2013-01-01

    Due to the presence of PCR inhibitors, PCR cannot be used directly on most clinical samples, including human urine, without pre-treatment. A magnetic bead-based strategy is one potential method to collect biomarkers from urine samples and separate the biomarkers from PCR inhibitors. In this report, a 1 mL urine sample was mixed within the bulb of a transfer pipette containing lyophilized nucleic acid-silica adsorption buffer and silica-coated magnetic beads. After mixing, the sample was transferred from the pipette bulb to a small diameter tube, and captured biomarkers were concentrated using magnetic entrainment of beads through pre-arrayed wash solutions separated by small air gaps. Feasibility was tested using synthetic segments of the 140 bp tuberculosis IS6110 DNA sequence spiked into pooled human urine samples. DNA recovery was evaluated by qPCR. Despite the presence of spiked DNA, no DNA was detectable in unextracted urine samples, presumably due to the presence of PCR inhibitors. However, following extraction with the magnetic bead-based method, we found that ∼50% of spiked TB DNA was recovered from human urine containing roughly 5×10(3) to 5×10(8) copies of IS6110 DNA. In addition, the DNA was concentrated approximately ten-fold into water. The final concentration of DNA in the eluate was 5×10(6), 14×10(6), and 8×10(6) copies/µL for 1, 3, and 5 mL urine samples, respectively. Lyophilized and freshly prepared reagents within the transfer pipette produced similar results, suggesting that long-term storage without refrigeration is possible. DNA recovery increased with the length of the spiked DNA segments from 10±0.9% for a 75 bp DNA sequence to 42±4% for a 100 bp segment and 58±9% for a 140 bp segment. The estimated LOD was 77 copies of DNA/µL of urine. The strategy presented here provides a simple means to achieve high nucleic acid recovery from easily obtained urine samples, which does not contain inhibitors of PCR.

  13. A Magnetic Bead-Based Method for Concentrating DNA from Human Urine for Downstream Detection

    PubMed Central

    Bordelon, Hali; Russ, Patricia K.; Wright, David W.; Haselton, Frederick R.

    2013-01-01

    Due to the presence of PCR inhibitors, PCR cannot be used directly on most clinical samples, including human urine, without pre-treatment. A magnetic bead-based strategy is one potential method to collect biomarkers from urine samples and separate the biomarkers from PCR inhibitors. In this report, a 1 mL urine sample was mixed within the bulb of a transfer pipette containing lyophilized nucleic acid-silica adsorption buffer and silica-coated magnetic beads. After mixing, the sample was transferred from the pipette bulb to a small diameter tube, and captured biomarkers were concentrated using magnetic entrainment of beads through pre-arrayed wash solutions separated by small air gaps. Feasibility was tested using synthetic segments of the 140 bp tuberculosis IS6110 DNA sequence spiked into pooled human urine samples. DNA recovery was evaluated by qPCR. Despite the presence of spiked DNA, no DNA was detectable in unextracted urine samples, presumably due to the presence of PCR inhibitors. However, following extraction with the magnetic bead-based method, we found that ∼50% of spiked TB DNA was recovered from human urine containing roughly 5×103 to 5×108 copies of IS6110 DNA. In addition, the DNA was concentrated approximately ten-fold into water. The final concentration of DNA in the eluate was 5×106, 14×106, and 8×106 copies/µL for 1, 3, and 5 mL urine samples, respectively. Lyophilized and freshly prepared reagents within the transfer pipette produced similar results, suggesting that long-term storage without refrigeration is possible. DNA recovery increased with the length of the spiked DNA segments from 10±0.9% for a 75 bp DNA sequence to 42±4% for a 100 bp segment and 58±9% for a 140 bp segment. The estimated LOD was 77 copies of DNA/µL of urine. The strategy presented here provides a simple means to achieve high nucleic acid recovery from easily obtained urine samples, which does not contain inhibitors of PCR. PMID:23861895

  14. Genetic DNA profile in urine and hair follicles from patients who have undergone allogeneic hematopoietic stem cell transplantation.

    PubMed

    Santurtún, Ana; Riancho, José A; Santurtún, Maite; Richard, Carlos; Colorado, M Mercedes; García Unzueta, Mayte; Zarrabeitia, María T

    2017-09-01

    Biological samples from patients who have undergone allogeneic hematopoietic stem cell transplantation (HSCT) constitute a challenge for individual identification. In this study we analyzed the genetic profiles (by the amplification of 15 autosomic STRs) of HSCT patients found in different types of samples (blood, hair and urine) that may be the source of DNA in civil or criminal forensic cases. Our results show that while in hair follicles the donor component was not detected in any patient, thus being a reliable source of biological material for forensic identification, mixed chimerism was detected in urine samples from all patient, and no correlation was found between the time elapsed from the transplant and the percentage of chimerism. These results certainly have practical implications if the urine is being considered as a source of DNA for identification purposes in HSTC patients. Moreover, taking into consideration that chimerism was found not only in patients with leukocyturia (given the hematopoietic origin of leukocytes, this was expected), but also in those without observable leukocytes in the sediment, we conclude that an alternative source or sources of donor DNA must be implicated. Copyright © 2017 The Chartered Society of Forensic Sciences. Published by Elsevier B.V. All rights reserved.

  15. Jet Fuel Exposure and Neurological Health in Military Personnel

    DTIC Science & Technology

    2011-07-01

    and dermal samples E Absorbed Dose measure: Exhaled breath, urine , blood F Lifestyle factors (smoking), use of protective equipment (gloves...toluene, ethylbenzene, xylene, and naphthalene. To assess personal absorbed dose levels to JP8 components, exhaled breath and urine samples were...the following primary analytes of interest were measured: benzene, toluene, ethylbenzene, xylene, and naphthalene. Pre- and post- shift urine samples

  16. The examination of urine samples for pathogenic microbes by the luciferase assay for ATP. 1: The effect of the presence of fungi, fungal like bacteria and kidney cells in urine samples

    NASA Technical Reports Server (NTRS)

    Bush, V. N.

    1973-01-01

    A method for accurately determining urinary tract infections in man is introduced. The method is based on adenosine triphosphate (ATP) concentration in urine samples after removing nonbacterial ATP. Adenosine triphosphate concentration is measured from the bioluminescent reaction of luciferase when mixed with ATP. An examination was also made of the effectiveness of rupturing agents on monkey kidney cells Candia albicans, a Rhodotorula species, and a Streptomyces species in determining whether these cells could contribute ATP to the bacterial ATP value of a urine sample.

  17. Development of an immunochromatographic assay for the β-adrenergic agonist feed additive zilpaterol.

    PubMed

    Shelver, Weilin L; Smith, David J

    2018-06-06

    Zilpaterol is a β-adrenergic agonist feed additive approved in the United States to increase weight gain and improve feed efficiency of cattle. A zilpaterol immunochromatographic assay was developed as an economical and user-friendly rapid detection method for zilpaterol and validated using urine and tissue samples derived from animal studies. The assay sensitivity was 1.7-23.2 ng g -1 or mL -1 across a variety of feed and animal matrices and did not cross-react with clenbuterol or ractopamine. No sample pre-treatment of cattle and sheep urine was needed, but horse urine and feed required dilution; skeletal muscle required solvent extraction prior to testing. Of 32 incurred sheep urine samples tested, zilpaterol content was correctly identified in all but 2 samples. Horse urine containing >10 ng mL -1 of incurred zilpaterol residue (n = 48) was correctly identified as zilpaterol positive. The assay correctly identified 0-day withdrawal sheep muscle samples as zilpaterol positive and the control and longer withdrawal day sheep muscle samples as negative. Zilpaterol was demonstrated to be stable in horse urine when stored at -20°C for 7 years.

  18. Quantification of sulfatides in dried blood and urine spots from metachromatic leukodystrophy patients by liquid chromatography/electrospray tandem mass spectrometry.

    PubMed

    Barcenas, Mariana; Suhr, Teryn R; Scott, C Ronald; Turecek, Frantisek; Gelb, Michael H

    2014-06-10

    Treatments are being developed for metachromatic leukodystrophy (MLD), suggesting the need for eventual newborn screening. Previous studies have shown that sulfatide molecular species are increased in the urine of MLD patients compared to samples from non-MLD individuals, but there is no data using dried blood spots (DBS), the most common sample available for newborn screening laboratories. We used ultra-high performance liquid chromatography/tandem mass spectrometry (UHPLC/MS/MS) to quantify sulfatides in DBS and dried urine spots from 14 MLD patients and 50 non-MLD individuals. Several sulfatide molecular species were increased in dried urine samples from all MLD samples compared to non-MLD samples. Sulfatides, especially low molecular species, were increased in DBS from MLD patients, but the sulfatide levels were relatively low. There was good separation in sulfatide levels between MLD and non-MLD samples when dried urine spots were used, but not with DBS, because DBS from non-MLD individuals have measurable levels of sulfatides. Sulfatide accumulation studies in urine, but not in DBS, emerges as the method of choice if newborn screening is to be proposed for MLD. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. USE OF DISPOSABLE DIAPERS TO COLLECT URINE IN EXPOSURE STUDIES

    EPA Science Inventory

    Large studies of children's health as it relates to exposures to chemicals in the environment often require measurements of biomarkers of chemical exposures or effects in urine samples. But collection of urine samples from infants and toddlers is difficult. For large exposure s...

  20. The Use of Chlorhexidine/n-Propyl Gallate (CPG) as an Ambient-Temperature Urine Preservative

    NASA Technical Reports Server (NTRS)

    Nillen, Jeannie L.; Smith, Scott M.

    2003-01-01

    A safe, effective ambient temperature urine preservative, chlorhexidine/n-propyl gallate (CPG), has been formulated for use during spacefli ght that reduces the effects of oxidation and bacterial contamination on sample integrity while maintaining urine pH. The ability of this preservative to maintain stability of nine key analytes was evaluated for a period of one year. CPG effectively maintained stability of a mmonia, total nitrogen, 3-methylhistidine, chloride, sodium, potassiu m, and urea; however, creatinine and osmolality were not preserved by CPG. These data indicate that CPG offers prolonged room-temperature storage for multiple urine analytes, reducing the requirements for f rozen urine storage on future spaceflights. Iii medical applications on Earth, this technology can allow urine samples to be collected in remote settings and eliminate the need to ship frozen samples.

  1. Use of a midstream clean catch mobile application did not lower urine contamination rates in an ED.

    PubMed

    Jacob, Mary S; Kulie, Paige; Benedict, Cameron; Ordoobadi, Alexander J; Sikka, Neal; Steinmetz, Erika; McCarthy, Melissa L

    2018-01-01

    Urine microscopy is a common test performed in emergency departments (EDs). Urine specimens can easily become contaminated by different factors, including the collection method. The midstream clean-catch (MSCC) collection technique is commonly used to reduce urine contamination. The urine culture contamination rate from specimens collected in our ED is 30%. We developed an instructional application (app) to show ED patients how to provide a MSCC urine sample. We hypothesized that ED patients who viewed our instructional app would have significantly lower urine contamination rates compared to patients who did not. We prospectively enrolled 257 subjects with a urinalysis and/or urine culture test ordered in the ED and asked them to watch our MSCC instructional app. After prospective enrollment was complete, we retrospectively matched each enrolled subject to an ED patient who did not watch the instructional app. Controls were matched to cases based on gender, type of urine specimen provided, ED visit date and shift. Urinalysis and urine culture contamination results were compared between the matched pairs using McNemar's test. The overall urine culture contamination rate of the 514 subjects was 38%. The majority of the matched pairs had a urinalysis (63%) or urinalysis plus urine culture (35%) test done. There were no significant differences in our urine contamination rates between the matched pairs overall or when stratified by gender, by prior knowledge of the clean catch process or by type of urine specimen. We did not see a lower contamination rate for patients who viewed our instructional app compared to patients who did not. It is possible that MSCC is not effective for decreasing urine specimen contamination. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Glucose urine test

    MedlinePlus

    Urine sugar test; Urine glucose test; Glucosuria test; Glycosuria test ... After you provide a urine sample, it is tested right away. The health care provider uses a dipstick made with a color-sensitive pad. The ...

  3. 24-hour urinary aldosterone excretion test

    MedlinePlus

    Aldosterone - urine; Addison disease - urine aldosterone; Cirrhosis - serum aldosterone ... A 24-hour urine sample is needed. You will need to collect your urine over 24 hours . Your health care provider will tell ...

  4. Development of a new protocol for rapid bacterial identification and susceptibility testing directly from urine samples.

    PubMed

    Zboromyrska, Y; Rubio, E; Alejo, I; Vergara, A; Mons, A; Campo, I; Bosch, J; Marco, F; Vila, J

    2016-06-01

    The current gold standard method for the diagnosis of urinary tract infections (UTI) is urine culture that requires 18-48 h for the identification of the causative microorganisms and an additional 24 h until the results of antimicrobial susceptibility testing (AST) are available. The aim of this study was to shorten the time of urine sample processing by a combination of flow cytometry for screening and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) for bacterial identification followed by AST directly from urine. The study was divided into two parts. During the first part, 675 urine samples were processed by a flow cytometry device and a cut-off value of bacterial count was determined to select samples for direct identification by MALDI-TOF-MS at ≥5 × 10(6) bacteria/mL. During the second part, 163 of 1029 processed samples reached the cut-off value. The sample preparation protocol for direct identification included two centrifugation and two washing steps. Direct AST was performed by the disc diffusion method if a reliable direct identification was obtained. Direct MALDI-TOF-MS identification was performed in 140 urine samples; 125 of the samples were positive by urine culture, 12 were contaminated and 3 were negative. Reliable direct identification was obtained in 108 (86.4%) of the 125 positive samples. AST was performed in 102 identified samples, and the results were fully concordant with the routine method among 83 monomicrobial infections. In conclusion, the turnaround time of the protocol described to diagnose UTI was about 1 h for microbial identification and 18-24 h for AST. Copyright © 2016 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  5. Lead Quantification in Urine Samples of Athletes by Coupling DLLME with UV-Vis Spectrophotometry.

    PubMed

    Faraji, Hakim; Helalizadeh, Masoumeh

    2017-04-01

    Urine lead level is one of the most employed measures of lead exposure and risk. The urine samples used in this study were obtained from ten healthy male cyclists. Dispersive liquid-liquid microextraction combined with ultraviolet and visible spectrophotometry was utilized for preconcentration, extraction, and determination of lead in urine samples. Optimization of the independent variables was carried out based on chemometric methods in three steps. According to the screening and optimization study, 133 μL of CCl 4 (extracting solvent), 1.34 mL ethanol (dispersing solvent), pH 2.0, 0.00 % of salt, and 0.1 % O,O-diethyl dithiophosphoric (chelating agent) were used as the optimum independent variables for microextraction and determination of lead. Under the optimized conditions, R 2 was 0.9991, and linearity range was 0.01-100 μg L -1 . Precision was evaluated in terms of repeatability and intermediate precision, with relative standard deviations being <9.1 and <15.3 %, respectively. The accuracy was estimated using urine samples of cyclists as real samples and it was confirmed. The relative error of ≤5 % was considered significant in the method specificity study. The lead concentration mean for the cyclists was 3.79 μg L -1 in urine samples. As a result, the proposed method is a robust technique to quantify lead concentrations higher than 11.6 ng L -1 in urine samples.

  6. Rapid Diagnosis of Tuberculosis from Analysis of Urine Volatile Organic Compounds

    PubMed Central

    Lim, Sung H.; Martino, Raymond; Anikst, Victoria; Xu, Zeyu; Mix, Samantha; Benjamin, Robert; Schub, Herbert; Eiden, Michael; Rhodes, Paul A.; Banaei, Niaz

    2017-01-01

    The World Health Organization has called for simple, sensitive, and non-sputum diagnostics for tuberculosis. We report development of a urine tuberculosis test using a colorimetric sensor array (CSA). The sensor comprised of 73 different indicators captures high-dimensional, spatiotemporal signatures of volatile chemicals emitted by human urine samples. The sensor responses to 63 urine samples collected from 22 tuberculosis cases and 41 symptomatic controls were measured under five different urine test conditions. Basified testing condition yielded the best accuracy with 85.5% sensitivity and 79.5% specificity. The CSA urine assay offers desired features needed for tuberculosis diagnosis in endemic settings. PMID:29057329

  7. Can nail, hair and urine be used for biomonitoring of human exposure to perfluorooctane sulfonate and perfluorooctanoic acid?

    PubMed

    Li, Jingguang; Guo, Feifei; Wang, Yuxin; Zhang, Jialing; Zhong, Yuxin; Zhao, Yunfeng; Wu, Yongning

    2013-03-01

    Because of the disadvantages of invasive sampling, it is desirable to explore non-invasive matrices for human biomonitoring of perfluorooctane sulfonate (PFOS) and perfluorooctanoic acid (PFOA). The aim of this study was to evaluate the application of nail, hair and urine for human biomonitoring of PFOS and PFOA. The concentrations of PFOS and PFOA in matched nail, hair, urine and serum samples collected from 64 donors were measured. The chemicals of interest were detected with high detection frequency in these matrices (90%-100%) except for PFOA in urine samples (56%). Generally, the gender influences on the levels of PFOS and PFOA in these non-invasive matrices were in agreement with that in serum. For PFOS, the coefficients of Spearman correlation between serum samples and nail, hair and urine samples were 0.786 (p<0.001), 0.545 (p<0.001) and 0.302 (p<0.05), respectively. For PFOA, the correlation was only observed between nail samples and serum samples with a correlation coefficient of 0.299 (p<0.05). The results suggested that nail has more potential than hair and urine to be applied in human biomonitoring for PFOS and PFOA in general populations. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Monitoring of exposure to methylpentanes by diffusive sampling and urine analysis for alcoholic metabolites.

    PubMed Central

    Kawai, T; Mizunuma, K; Yasugi, T; Horiguchi, S; Iguchi, H; Mutti, A; Ghittori, S; Ikeda, M

    1995-01-01

    OBJECTIVES--To investigate the possibilities of personal ambient monitoring and biological monitoring for methylpentane isomers. METHODS--The performance of activated carbon cloth to absorb 2- and 3-methylpentane was studied by experimental vapour exposure followed by solvent extraction and gas chromatography (GC). Urine from workers and rats exposed to 2- and 3-methylpentane was analysed by GC with or without acid or enzymatic hydrolysis. RESULTS--Carbon cloth absorbed 2- and 3-methylpentane linearly to exposures up to eight hours and to 400 ppm, and was sensitive enough to detect a 15 minute peak of exposure. The two isomers were clearly separated from hexane on a DB-1 column. For analysis of the urine, enzymatic hydrolysis was superior to acid hydrolysis. Exposure of rats to methylpentane vapours showed that 2-methyl-2-pentanol and 3-methyl-2-pentanol were excreted in urine in proportion to the dose of 2-methylpentane and 3-methylpentane, respectively. 2-Methyl derivatives of 1-, 3-, and 4-propanol, 2-methylpentane-2,4-diol, and 3-methyl-2-pentanol were minor metabolites. Analysis of urine from the exposed workers showed that 2-methyl- and 3-methyl-2-pentanol are leading urinary metabolites after exposure to the corresponding methylpentane. CONCLUSIONS--Diffusive sampling is applicable to monitor 2- and 3-methylpentane vapours as is the case for hexane vapour. 2-Methyl-2-pentanol and 3-methyl-2-pentanol will be markers of occupational exposure to 2-methylpentane and 3-methylpentane, respectively. Also, 2-methylpentane-2,4-diol might be a marker of exposure to 2-methylpentane. PMID:8535496

  9. Chiral liquid chromatography-mass spectrometry (LC-MS/MS) method development for the detection of salbutamol in urine samples.

    PubMed

    Chan, Sue Hay; Lee, Warren; Asmawi, Mohd Zaini; Tan, Soo Choon

    2016-07-01

    A sequential solid-phase extraction (SPE) method was developed and validated using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) for the detection and quantification of salbutamol enantiomers in porcine urine. Porcine urine samples were hydrolysed with β-glucuronidase/arylsulfatase from Helix pomatia and then subjected to a double solid-phase extraction (SPE) first using the Abs-Elut Nexus SPE and then followed by the Bond Elut Phenylboronic Acid (PBA) SPE. The salbutamol enantiomers were separated using the Astec CHIROBIOTIC™ T HPLC column (3.0mm×100mm; 5μm) maintained at 15°C with a 15min isocratic run at a flow rate of 0.4mL/min. The mobile phase constituted of 5mM ammonium formate in methanol. Salbutamol and salbutamol-tert-butyl-d9 (internal standard, IS) was monitored and quantified with the multiple reaction monitoring (MRM) mode. The method showed good linearity for the range of 0.1-10ng/mL with limit of quantification at 0.3ng/mL. Analysis of the QC samples showed intra- and inter-assay precisions to be less than 5.04%, and recovery ranging from 83.82 to 102.33%. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Webb-Robertson, Bobbie-Jo; Kim, Young -Mo; Zink, Erika M.

    Urease pre-treatment of urine has been utilized since the early 1960s to remove high levels of urea from samples prior to further processing and analysis by gas chromatography-mass spectrometry (GC-MS). Aside from the obvious depletion or elimination of urea, the effect, if any, of urease pre-treatment on the urinary metabolome has not been studied in detail. Here, we report the results of three separate but related experiments that were designed to assess possible indirect effects of urease pre-treatment on the urinary metabolome as measured by GC-MS. In total, 235 GC-MS analyses were performed and over 106 identified and 200 unidentifiedmore » metabolites were quantified across the three experiments. The results showed that data from urease pre-treated samples 1) had the same or lower coefficients of variance among reproducibly detected metabolites, 2) more accurately reflected quantitative differences and the expected ratios among different urine volumes, and 3) increased the number of metabolite identifications. Altogether, we observed no negative consequences of urease pre-treatment. In contrast, urease pretreatment enhanced the ability to distinguish between volume-based and biological sample types compared to no treatment. Taken together, these results show that urease pretreatment of urine offers multiple beneficial effects that outweigh any artifacts that may be introduced to the data in urinary metabolomics analyses.« less

  11. Chromatographic determination of harmalans in the urine of autistic children.

    PubMed

    Kałużna-Czaplińska, Joanna; Jóźwik-Pruska, Jagoda; Axt, Andrea

    2017-09-01

    This paper presents a new approach to autism - a complex and still enigmatic condition. We present the results of our preliminary research which was based on the detection of the hallucinogenic substance 6- (or 10-)methoxyharmalan in the urine samples of autistic children with the use of chromatographic methods. Additionally, we aim to describe the relationship between the level of tryptophan and harmalan, and the influence of supplementation on the level of this compound. We applied HPLC-UV/vis, HPLC-DAD and LC-MS in order to determine McIsaac's compound in the urine samples obtained from autistic children (n = 132) and healthy individuals (n = 10). The level of tryptophan was quantified with the use of GC-MS. Our research shows the presence of the McIsaac's compound in 110 samples of ASD children contrary to healthy children, where it was not found. No relationship between the level of tryptophan and 6-methoxyharmalan was noticed. The study shows a strong influence of melatonin supplementation on the presence of the McIsaac's compound. We believe that the results of our research can contribute to a better understanding of autism spectrum disorders. Moreover, our findings can form the basis for other studies focused on autism, eventually making it possible to understand its etiology. Copyright © 2017 John Wiley & Sons, Ltd.

  12. DIETARY SODIUM ADHERENCE IS POOR IN CHRONIC HEART FAILURE PATIENTS

    PubMed Central

    Basuray, Anupam; Dolansky, Mary; Josephson, Richard; Sattar, Abdus; Grady, Ellen M.; Vehovec, Anton; Gunstad, John; Redle, Joseph; Fang, James; Hughes, Joel W.

    2015-01-01

    Background We sought to determine the rates and predictors of dietary sodium restriction, while evaluating the reliability of the 24-hour urine collection as a tool to estimate dietary sodium intake in heart failure (HF) patients. Methods and Results We evaluated the 24-hour urinary sodium excretion of 305 outpatients with HF and reduced ejection fraction who were educated on following a <2 gm sodium diet. The mean sodium excretion using a single sample from each participant was 3.15 ± 1.58 grams, and 23% were adherent to the <2 gm recommendation. 168 participants provided two samples with urinary creatinine excretion within normative range. Averaging both resulted in a mean sodium excretion of 3.21 ± 1.20 grams and lower adherence rates to the <2-gram diet: 14% versus 23% (p=0.019). Multivariate logistic regression showed only male sex and higher BMI was associated with non-adherence (OR male: 2.20, 95% CI: 1.25-3.88, OR one unit BMI: 1.05, 95% CI: 1.01-1.10). Bland-Altman plots of urinary sodium and creatinine showed poor reproducibility between samples. Conclusions In this chronic HF population, sodium consumption probably exceeds recommended amounts, particularly in men and those with higher BMI. Urine analyses were not highly reproducible, suggesting variation in both diet and urine collection. PMID:25576680

  13. Novel micro-extraction by packed sorbent procedure for the liquid chromatographic analysis of antiepileptic drugs in human plasma and urine.

    PubMed

    Rani, Susheela; Malik, Ashok K; Singh, Baldev

    2012-02-01

    A method for the simultaneous determination of the antiepileptic drugs, phenobarbital (PHB), phenytoin (PTN), carbamazepine (CBZ), primidone (PRM) and oxcarbazepine (OXC) in human plasma and urine samples by using micro-extraction in a packed syringe as the sample preparation method connected with LC/UV (MEPS/LC/UV) is described. Micro-extraction in a packed syringe (MEPS) is a new miniaturized, solid-phase extraction technique that can be connected online to gas or liquid chromatography without any modifications. In MEPS approximately 1 mg of the solid packing material is inserted into a syringe (100-250 μL) as a plug. Sample preparation takes place on the packed bed. The bed can be coated to provide selective and suitable sampling conditions. The new method is very promising, easy to use, fully automated, inexpensive and quick. The standard curves were obtained within the concentration range 1-500 ng/mL in both plasma and urine samples. The results showed high correlation coefficients (R(2) >0.988) for all of the analytes within the calibration range. The extraction recovery was found to be between 88.56 and 99.38%. The limit of quantification was found to be between 0.132 and 1.956 ng/mL. The precision (RSD) values of quality control samples (QC) had a maximum deviation of 4.9%. A comparison of the detection limits with similar methods indicates high sensitivity of the present method. The method is applied for the analysis of these drugs in real urine and plasma samples of epileptic patients. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Comparative Evaluation of Three Nucleic Acid-Based Assays for BK Virus Quantification

    PubMed Central

    Descamps, Veronique; Martin, Elodie; Morel, Virginie; François, Catherine; Helle, François; Duverlie, Gilles; Castelain, Sandrine

    2015-01-01

    With the growing importance of BK virus (BKV), effective and efficient screening for BKV replication in plasma and urine samples is very important for monitoring renal transplant and hematopoietic stem cell transplant recipients, who are at increased risk of BKV-associated diseases. However, recent assays proposed by many manufacturers have not been tested, and the available tests have not been standardized. The aim of the present study was to evaluate and compare the performances of three commercially available kits, R-gene, GeneProof, and RealStar, on plasma and urine specimens from patients infected with various genotypes and to determine the correlations with the results from a reference laboratory. A qualitatively excellent global agreement (96.8%) was obtained. RealStar PCR tended to give a higher sensitivity, especially for subtype Ib1 samples. Comparison of 30 plasma samples and 53 urine samples showed a good agreement between the three assays, with Spearman's Rho correlation coefficient values falling between 0.92 and 0.98 (P < 0.001). Moreover, a perfect correlation was obtained for comparison of the assay performances with the AcroMetrix BKV panel (P < 0.001 for all comparisons). According to Bland-Altman analysis, more than 95% (240/249 comparisons) of sample comparisons were situated in the range of the mean ± 2 standard deviations (SD). The greatest variability between assays was observed for 10.2% of subtype Ib2 samples, with differences of >1 log10 copies/ml. In conclusion, this study demonstrated the reliable and comparable performances of the R-gene, GeneProof, and RealStar real-time PCR systems for quantification of BKV in urine and plasma samples. All three real-time PCR assays are appropriate for screening of BKV replication in patients. PMID:26424842

  15. Lower urinary tract infection and bacterial colonization in patient with double J ureteral stent.

    PubMed

    Joshi, R; Singh, D R; Sharma, S

    2011-10-01

    The aim of this study is to investigate the bacteriology of urinary tract infection associated with indwelling DJ stent. A total of 60 patients were included and 14 lost during follow up. Study period was for 6 months carried out in the department of surgery, Kathmandu Medical College. Prophylactic antibiotic was given at the time of intervention. Mid stream urine samples for routine and culture were sent before intervention. Urine samples during DJ removal and DJ tip cultures were also sent. All patients were "stented" during the various open and endourolgical procedures. Patients were clinically followed for a period till the DJ was removed. Statistical Package for Scientific Study (SPSS) 11, Chi square Test was used for statistical analysis. A total of 46 cases were included. Mean age in years was 35.70 (10-78 years). Male were 22 and female 24. Eleven patients (23.91%) had stent placed less than 30 days and 35 patients (76.08%) had it for equal or more than 30 days. DJ indwelling time was in between 12-86 days. Bacterial colonies were found in 28.3% (13 of 46) of the urine samples and 30.4% (14 of 46) from the tip of the DJ stent segment. Of the pathogens identified, E. coli was found to be the most common. An increased stent colonization rate was associated with implantation time, female sex. On urine culture 70.21% had no growth, 14.89% E. coli, 4.25% Klebsiella, Actinobacter, 2.12% E. coli/kleb, multiple org, psuedomonas. Ten patients (21.7%) had positive urine culture before stent insertion. Thirteen patients (28.3%) were shown to have positive urine culture on stent removal. Fourteen patients (30.4%) had positive DJ stent culture. Positive urine culture and positive DJ tip cultures had strong correlation. Longer duration of placement of stent showed stent colonization. The commonest pathogen was E. coli.

  16. Changes in urine composition after trauma facilitate bacterial growth

    PubMed Central

    2012-01-01

    Background Critically ill patients including trauma patients are at high risk of urinary tract infection (UTI). The composition of urine in trauma patients may be modified due to inflammation, systemic stress, rhabdomyolysis, life support treatment and/or urinary catheter insertion. Methods Prospective, single-centre, observational study conducted in patients with severe trauma and without a history of UTIs or recent antibiotic treatment. The 24-hour urine samples were collected on the first and the fifth days and the growth of Escherichia coli in urine from patients and healthy volunteers was compared. Biochemical and hormonal modifications in urine that could potentially influence bacterial growth were explored. Results Growth of E. coli in urine from trauma patients was significantly higher on days 1 and 5 than in urine of healthy volunteers. Several significant modifications of urine composition could explain these findings. On days 1 and 5, trauma patients had an increase in glycosuria, in urine iron concentration, and in the concentrations of several amino acids compared to healthy volunteers. On day 1, the urinary osmotic pressure was significantly lower than for healthy volunteers. Conclusion We showed that urine of trauma patients facilitated growth of E. coli when compared to urine from healthy volunteers. This effect was present in the first 24 hours and until at least the fifth day after trauma. This phenomenon may be involved in the pathophysiology of UTIs in trauma patients. Further studies are required to define the exact causes of such modifications. PMID:23194649

  17. The Accuracy of the Sysmex UF-1000i in Urine Bacterial Detection Compared With the Standard Urine Analysis and Culture.

    PubMed

    Erdman, Patrick; Anderson, Brian; Zacko, J Christopher; Taylor, Kirk; Donaldson, Keri

    2017-11-01

    - Urinary tract infections are characterized by the presence of microbial pathogens within the urinary tract. They represent one of the most common infections in hospitalized and clinic patients. - To model the parameters of the Sysmex UF-1000i to the gold standard, urine culture, and to compare the detection of dipstick leukocyte esterase and nitrates to urine cultures and UF-1000i results. - Data were compared from urine samples collected in sterile containers for bacterial culture and microscopic analysis. One sample was used to inoculate a 5% sheep blood agar and MacConkey agar plate using a 0.001-mL calibrated loop. The second sample was analyzed by urinalysis-associated microscopy. The media plates were investigated for growth after 18 to 24 hours of aerobic incubation at 37°C. The second sample was analyzed for bacteria and leukocytes with the Sysmex UF-1000i according to the manufacturer's guidelines. Three definitions for culture results, sensitivity, and specificity at different cutoff values were calculated for the UF-1000i. - The negative predictive value for any positive culture in the adult population included in the study was 95.5%, and the negative predictive value for positive cultures containing growth of 100 000 or more colony-forming units was 99.3% using the Sysmex UF-1000i. - Sysmex UF-1000i showed 98% sensitivity and 93.7% specificity with a 95.5% negative predictive value. Thus, a negative screen with the UF-1000i using defined thresholds for white blood cell counts and bacteria was likely to be a true negative, decreasing the need for presumptive antibiotics.

  18. NHEXAS PHASE I MARYLAND STUDY--PESTICIDE METABOLITES IN URINE ANALYTICAL RESULTS

    EPA Science Inventory

    The Pesticide Metabolites in Urine data set contains analytical results for measurements of up to 9 pesticides in 345 urine samples over 79 households. Each sample was collected from the primary respondent within each household during the study and represented the first morning ...

  19. NHEXAS PHASE I ARIZONA STUDY--PESTICIDE METABOLITES IN URINE ANALYTICAL RESULTS

    EPA Science Inventory

    The Pesticide Metabolites in Urine data set contains analytical results for measurements of up to 4 pesticide metabolites in 176 urine samples over 176 households. Each sample was collected from the primary respondent within each household during Stage III of the NHEXAS study. ...

  20. Detection of novel visible-light region absorbance peaks in the urine after alkalization in patients with alkaptonuria.

    PubMed

    Tokuhara, Yasunori; Shukuya, Kenichi; Tanaka, Masami; Mouri, Mariko; Ohkawa, Ryunosuke; Fujishiro, Midori; Takahashi, Tomoo; Okubo, Shigeo; Yokota, Hiromitsu; Kurano, Makoto; Ikeda, Hitoshi; Yamaguchi, Seiji; Inagaki, Shinobu; Ishige-Wada, Mika; Usui, Hiromi; Yatomi, Yutaka; Shimosawa, Tatsuo

    2014-01-01

    Alkaptonuria, caused by a deficiency of homogentisate 1,2-dioxygenase, results in the accumulation of homogentisic acid (2,5-dihydroxyphenylacetic acid, HGA) in the urine. Alkaptonuria is suspected when the urine changes color after it is left to stand at room temperature for several hours to days; oxidation of homogentisic acid to benzoquinone acetic acid underlies this color change, which is accelerated by the addition of alkali. In an attempt to develop a facile screening test for alkaptonuria, we added alkali to urine samples obtained from patients with alkaptonuria and measured the absorbance spectra in the visible light region. We evaluated the characteristics of the absorption spectra of urine samples obtained from patients with alkaptonuria (n = 2) and compared them with those of urine specimens obtained from healthy volunteers (n = 5) and patients with phenylketonuria (n = 3), and also of synthetic homogentisic acid solution after alkalization. Alkalization of the urine samples and HGA solution was carried out by the addition of NaOH, KOH or NH4OH. The sample solutions were incubated at room temperature for 1 min, followed by measurement of the absorption spectra. Addition of alkali to alkaptonuric urine yielded characteristic absorption peaks at 406 nm and 430 nm; an identical result was obtained from HGA solution after alkalization. The absorbance values at both 406 nm and 430 nm increased in a time-dependent manner. In addition, the absorbance values at these peaks were greater in strongly alkaline samples (NaOH- KOH-added) as compared with those in weakly alkaline samples (NH4OH-added). In addition, the peaks disappeared following the addition of ascorbic acid to the samples. We found two characteristic peaks at 406 nm and 430 nm in both alkaptonuric urine and HGA solution after alkalization. This new quick and easy method may pave the way for the development of an easy method for the diagnosis of alkaptonuria.

  1. Detection of Novel Visible-Light Region Absorbance Peaks in the Urine after Alkalization in Patients with Alkaptonuria

    PubMed Central

    Tokuhara, Yasunori; Shukuya, Kenichi; Tanaka, Masami; Mouri, Mariko; Ohkawa, Ryunosuke; Fujishiro, Midori; Takahashi, Tomoo; Okubo, Shigeo; Yokota, Hiromitsu; Kurano, Makoto; Ikeda, Hitoshi; Yamaguchi, Seiji; Inagaki, Shinobu; Ishige-Wada, Mika; Usui, Hiromi; Yatomi, Yutaka; Shimosawa, Tatsuo

    2014-01-01

    Background Alkaptonuria, caused by a deficiency of homogentisate 1,2-dioxygenase, results in the accumulation of homogentisic acid (2,5-dihydroxyphenylacetic acid, HGA) in the urine. Alkaptonuria is suspected when the urine changes color after it is left to stand at room temperature for several hours to days; oxidation of homogentisic acid to benzoquinone acetic acid underlies this color change, which is accelerated by the addition of alkali. In an attempt to develop a facile screening test for alkaptonuria, we added alkali to urine samples obtained from patients with alkaptonuria and measured the absorbance spectra in the visible light region. Methods We evaluated the characteristics of the absorption spectra of urine samples obtained from patients with alkaptonuria (n = 2) and compared them with those of urine specimens obtained from healthy volunteers (n = 5) and patients with phenylketonuria (n = 3), and also of synthetic homogentisic acid solution after alkalization. Alkalization of the urine samples and HGA solution was carried out by the addition of NaOH, KOH or NH4OH. The sample solutions were incubated at room temperature for 1 min, followed by measurement of the absorption spectra. Results Addition of alkali to alkaptonuric urine yielded characteristic absorption peaks at 406 nm and 430 nm; an identical result was obtained from HGA solution after alkalization. The absorbance values at both 406 nm and 430 nm increased in a time-dependent manner. In addition, the absorbance values at these peaks were greater in strongly alkaline samples (NaOH- KOH-added) as compared with those in weakly alkaline samples (NH4OH-added). In addition, the peaks disappeared following the addition of ascorbic acid to the samples. Conclusions We found two characteristic peaks at 406 nm and 430 nm in both alkaptonuric urine and HGA solution after alkalization. This new quick and easy method may pave the way for the development of an easy method for the diagnosis of alkaptonuria. PMID:24466168

  2. Mutagenic activity of overnight urine from healthy non-smoking subjects.

    PubMed

    Pavanello, Sofia; Lupi, Silvia; Pulliero, Alessandra; Gregorio, Pasquale; Saia, Bruno Onofrio; Clonfero, Erminio

    2007-03-01

    Urinary mutagenicity was evaluated in relation to environmental mutagen exposure (i.e., diet, indoor/outdoor activities, residential area etc.) on the day prior to sample collection, and also considering factors that contribute to the variability of Salmonella mutagenicity assay results. Overnight urine samples from 283 healthy non-smoking residents of northeast Italy (46% males, 20-62 years) were analyzed for mutagenicity on sensitive Salmonella typhimurium strain YG1024 with S9 mix employing the preincubation version of the plate incorporation assay (i.e., the Salmonella reverse mutation test). Urinary mutagenicity varied between 0.02 and 9.84 rev/ equiv. ml, and 7% of samples were positive (i.e., sample elicited a two-fold increase in revertants). There was an evident increase in mutagenicity in subjects with increased intake of mutagen-rich meals (n = 80) (P < 0.01 and positive urine 13% vs. 5%, P = 0.025). Indoor-exposed subjects (n = 65) also showed a higher percentage of positive urine (14% vs. 5%, P = 0.015). In particular, those subjects exposed to cooking fumes the previous evening (n = 28) revealed higher urinary mutagenicity (P = 0.035, positive urine 25% vs. 5%, P < 0.001) than non-indoor exposed. The sources of variability of the mutagenicity assay, mainly the histidine content of the urine concentrate (z = 4.06, P < 0.0001), and to a lesser extent bacterial inoculum size (z = 2.33, P = 0.019), also significantly influenced urinary mutagenicity values. In a linear multiple regression analysis, their effects were still significant (i.e., histidine content P = 0.026 and inoculum size P = 0.021), but the effects of diet, indoor exposure, and other environmental exposures (i.e., traffic and heating system exhausts, residential area) were not. It is concluded that the previous day's exposure to mutagen-rich meals and cooking fumes may influence the presence of mutagenic activity in the overnight urine of non-smoking subjects. This mutagenic activity, which remains in contact with bladder mucosa for several hours, could be considered risk factors for colorectal adenoma and possibly other cancers (i.e., bladder) in non-smokers. Accurate control of histidine content and bacterial inoculum size is strongly recommended when investigating the mutagenic activity of urine from non-smokers. (c) 2007 Wiley-Liss, Inc.

  3. Tracer techniques for urine volume determination and urine collection and sampling back-up system

    NASA Technical Reports Server (NTRS)

    Ramirez, R. V.

    1971-01-01

    The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.

  4. Diagnostic utility and cost-effectiveness of reflex bacterial culture for the detection of urinary tract infection in dogs with low urine specific gravity.

    PubMed

    Tivapasi, Musavenga T; Hodges, Joanne; Byrne, Barbara A; Christopher, Mary M

    2009-09-01

    Urinary tract infections (UTIs) may be subclinical or difficult to detect in dilute urine as sediment abnormalities may not be observed. In our laboratory, bacterial culture is automatically performed (reflex culture) on samples with urine specific gravity (USG)< or =1.013 to increase the likelihood of detecting infection. The value of routine culture of dilute urine, however, has not been fully assessed. The purpose of this retrospective study was to evaluate the frequency of positive bacterial cultures and analyze the diagnostic utility and cost-effectiveness of culture compared with routine sediment examination for detecting UTI in dilute urine specimens from dogs. Urinalysis and concurrent aerobic bacterial culture results were obtained from the electronic medical record system at the University of California-Davis Veterinary Medical Teaching Hospital for samples with USG< or =1.013 analyzed from July 1998 through January 2005. Urine collection method, presence of leukocytes and bacteria, bacterial culture results, and clinical diagnosis were recorded. Cost-effectiveness of reflex culture, based on low USG as the sole criterion, was evaluated. Of 1264 urine specimens, 106 (8.4%) had positive bacterial cultures. Using culture as the gold standard, sediment evaluation had a diagnostic sensitivity of 58.5% and specificity of 98.3% (diagnostic accuracy 94.9%). An additional cost of $60 per patient was incurred, leading to average annual costs of $11,668 for reflex bacterial cultures of all samples with low USG, regardless of collection method. Within our study population, 10 urine samples needed to be cultured for each true positive result. The sensitivity of urine sediment evaluation is low for UTI in dilute urine samples; however, reflex bacterial culture does not appear to be cost-effective in dogs with USG< or =1.013 in the absence of active urine sediment or high clinical suspicion for UTI.

  5. SERS quantitative urine creatinine measurement of human subject

    NASA Astrophysics Data System (ADS)

    Wang, Tsuei Lian; Chiang, Hui-hua K.; Lu, Hui-hsin; Hung, Yung-da

    2005-03-01

    SERS method for biomolecular analysis has several potentials and advantages over traditional biochemical approaches, including less specimen contact, non-destructive to specimen, and multiple components analysis. Urine is an easily available body fluid for monitoring the metabolites and renal function of human body. We developed surface-enhanced Raman scattering (SERS) technique using 50nm size gold colloidal particles for quantitative human urine creatinine measurements. This paper shows that SERS shifts of creatinine (104mg/dl) in artificial urine is from 1400cm-1 to 1500cm-1 which was analyzed for quantitative creatinine measurement. Ten human urine samples were obtained from ten healthy persons and analyzed by the SERS technique. Partial least square cross-validation (PLSCV) method was utilized to obtain the estimated creatinine concentration in clinically relevant (55.9mg/dl to 208mg/dl) concentration range. The root-mean square error of cross validation (RMSECV) is 26.1mg/dl. This research demonstrates the feasibility of using SERS for human subject urine creatinine detection, and establishes the SERS platform technique for bodily fluids measurement.

  6. Percutaneous absorption of selenium sulfide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farley, J.; Skelly, E.M.; Weber, C.B.

    1986-01-01

    The purpose of this study was to determine selenium levels in the urine of Tinea patients before and after overnight application of a 2.5% selenium sulfide lotion. Selenium was measured by atomic absorption spectroscopy (AAS). Hydride generation and carbon rod atomization were studied. It was concluded from this study that selenium is absorbed through intact skin. Selenium is then excreted, at least partially, in urine, for at least a week following treatment. The data show that absorption and excretion of selenium vary on an individual basis. Selenium levels in urine following a single application of selenium sulfide lotion do notmore » indicate that toxic amounts of selenium are being absorbed. Repeated treatments with SeS/sub 2/ result in selenium concentrations in urine which are significantly higher than normal. Significant matrix effects are observed in the carbon rod atomization of urine samples for selenium determinations, even in the presence of a matrix modifier such as nickel. The method of standard additions is required to obtain accurate results in the direct determination of selenium in urine by carbon rod AAS.« less

  7. Repetitive reddish discoloration of urine in a female adolescent following short-distance walking on a smooth road: Questions.

    PubMed

    Siomou, Ekaterini; Baziou, Maria; Premetis, Evagelos; Vercellati, Cristina; Chaliasos, Nikolaos; Makis, Alexandros

    2017-12-01

    A previously healthy 15-year-old girl was evaluated following five episodes of reddish urine discoloration after walking for approximately 30 min on a smooth roadway. In each episode, the discoloration lasted for four to five urinations and followed by normal urine dipstick tests. No other exercise-produced urine discoloration and no other symptoms were reported. Laboratory evaluation during the episodes revealed a reddish urine sample with 3+ hemoglobin/myoglobin and absence of hematuria. Full blood count, serum creatinine, liver function tests, and electrolyte levels were all within normal limits. Myoglobulinuria was excluded, since muscle enzymes were within normal limits. Blood smear analysis showed mild anisopoikilocytosis with stomatocytes and ovalocytes, leading to extended evaluation for erythrocyte disorders. This case is interesting in that the hemoglobinuria occurred after mild walking and was accompanied by erythrocyte morphological changes. This quiz discusses the differential diagnosis of hemoglobinuria with particular reference to the conditions of appearance (after walking) and emphasizes the importance of step-by-step investigations to reach a definitive diagnosis.

  8. Urinalysis in children and adolescents.

    PubMed

    Utsch, Boris; Klaus, Günter

    2014-09-12

    Urinalysis is the most commonly performed biochemical test in infancy and early childhood. The urine sample should be correctly obtained, age-specific aspects should be considered, and age-dependent reference values should be used. This review is based on a selective literature search in electronic databases, textbooks, and guidelines from Germany and abroad on the acquisition of urine samples and the performance of urinalysis in infancy and early childhood. The timing and mode of acquisition of the urine sample affect the assessment of hematuria, proteinuria, leukocyturia, nitrituria, and the uropathogenic bacterial colony count in the urine culture. Dipstick tests can be used for targeted screening for these features. The test results should be interpreted together with the findings of urine microscopy, the medical history, and the physical examination. Proteinuria should be quantified and differentiated; both of these things can be done either from collected urine or (especially in infants and young children) from a spontaneously voided urine sample, by determination of the protein/creatinine quotient. Orthostatic proteinuria in an adolescent requires no further evaluation or treatment. Hematuria should be characterized as either glomerular or non-glomerular erythrocyturia. Asymptomatic, isolated microhematuria in childhood is not uncommon and often transient; in the absence of a family history, it usually does not require an extensive work-up. Proteinuria combined with hematuria should arouse the suspicion of glomerulonephritis. Urinalysis in infancy and early childhood is a simple and informative diagnostic test as long as the urine sample has been obtained properly and the results are interpreted appropriately for this age group.

  9. Comparison of osmolality and refractometric readings of Hispaniolan Amazon parrot (Amazona ventralis) urine.

    PubMed

    Brock, A Paige; Grunkemeyer, Vanessa L; Fry, Michael M; Hall, James S; Bartges, Joseph W

    2013-12-01

    To evaluate the relationship between osmolality and specific gravity of urine samples from clinically normal adult parrots and to determine a formula to convert urine specific gravity (USG) measured on a reference scale to a more accurate USG value for an avian species, urine samples were collected opportunistically from a colony of Hispaniolan Amazon parrots (Amazona ventralis). Samples were analyzed by using a veterinary refractometer, and specific gravity was measured on both canine and feline scales. Osmolality was measured by vapor pressure osmometry. Specific gravity and osmolality measurements were highly correlated (r = 0.96). The linear relationship between refractivity measurements on a reference scale and osmolality was determined. An equation was calculated to allow specific gravity results from a medical refractometer to be converted to specific gravity values of Hispaniolan Amazon parrots: USGHAp = 0.201 +0.798(USGref). Use of the reference-canine scale to approximate the osmolality of parrot urine leads to an overestimation of the true osmolality of the sample. In addition, this error increases as the concentration of urine increases. Compared with the human-canine scale, the feline scale provides a closer approximation to urine osmolality of Hispaniolan Amazon parrots but still results in overestimation of osmolality.

  10. Pyrazine Analogues Are Active Components of Wolf Urine That Induce Avoidance and Freezing Behaviours in Mice

    PubMed Central

    Osada, Kazumi; Kurihara, Kenzo; Izumi, Hiroshi; Kashiwayanagi, Makoto

    2013-01-01

    Background The common grey wolf (Canis lupus) is found throughout the entire Northern hemisphere and preys on many kinds of mammals. The urine of the wolf contains a number of volatile constituents that can potentially be used for predator–prey chemosignalling. Although wolf urine is put to practical use to keep rabbits, rodents, deer and so on at bay, we are unaware of any prior behavioural studies or chemical analyses regarding the fear-inducing impact of wolf urine on laboratory mice. Methodology/Principal Findings Three wolf urine samples harvested at different times were used in this study. All of them induced stereotypical fear-associated behaviors (i.e., avoidance and freezing) in female mice. The levels of certain urinary volatiles varied widely among the samples. To identify the volatiles that provoked avoidance and freezing, behavioural, chemical, and immunohistochemical analyses were performed. One of the urine samples (sample C) had higher levels of 2,6-dimethylpyrazine (DMP), trimethylpyrazine (TMP), and 3-ethyl-2,5-dimethyl pyrazine (EDMP) compared with the other two urine samples (samples A and B). In addition, sample C induced avoidance and freezing behaviours more effectively than samples A and B. Moreover, only sample C led to pronounced expression of Fos-immunoreactive cells in the accessory olfactory bulb (AOB) of female mice. Freezing behaviour and Fos immunoreactivity were markedly enhanced when the mice were confronted with a mixture of purified DMP, TMP, and EDMP vs. any one pyrazine alone. Conclusions/Significance The current results suggest that wolf urinary volatiles can engender aversive and fear-related responses in mice. Pyrazine analogues were identified as the predominant active components among these volatiles to induce avoidance and freezing behaviours via stimulation of the murine AOB. PMID:23637901

  11. Evidence for false-positive results for boldenone testing of veal urine due to faecal cross-contamination during sampling.

    PubMed

    Sgoifo Rossi, C A; Arioli, F; Bassini, A; Chiesa, L M; Dell'Orto, V; Montana, M; Pompa, G

    2004-08-01

    European Directive 96/22/EC, which controls veterinary residues in animals, does not permit the presence of synthetic growth promoters in products of animal origin or in livestock. Boldenone is categorized in class A3 (growth promoters -- steroids) and is thus a banned substance. Testing of veal urine for banned substances is part of the European Union statutory programme for animals going into the food chain. In relation to this monitoring, three studies were conducted to investigate the apparent presence of the banned growth promoter boldenone in veal urine, which was suspected as being caused by interference from faecal contamination of the sample. In the first study, urine samples were collected at different times (time 0 and after 30 min) using (1) a conventional zoonotechnical apron and (2) a technique designed specifically to avoid faecal contamination ('kettle'). This resulted in samples that were, respectively, positive and negative for the presence of alpha-boldenone (alpha-BOL). In a second study, urine samples negative to alpha-BOL were collected from eight veal calves, but became positive after deliberate faecal contamination. In a third study, data obtained from the Italian RNP (Residual National Program) indicated that 18.1% of 3295 urine samples collected using the zootechnical apron were positive for alpha-BOL and 2.1% for beta-boldenone (beta-BOL), whilst of 902 samples collected using the kettle, beta-BOL was not detected in any samples and only 0.2% were positive to alpha-BOL, in concentrations lower than 2 ng ml(-1). These results further support the supposition that faecal contamination of the urine during sample collection can lead to false-positive results during boldenone analysis.

  12. NHEXAS PHASE I MARYLAND STUDY--METALS IN URINE ANALYTICAL RESULTS

    EPA Science Inventory

    The Metals in Urine data set contains analytical results for measurements of up to 3 metals in 376 urine samples over 80 households. Each sample was collected from the primary respondent within each household during the study and represented the first morning void of either Day ...

  13. Quantitative phase imaging to improve the diagnostic accuracy of urine cytology.

    PubMed

    Pham, Hoa V; Pantanowitz, Liron; Liu, Yang

    2016-09-01

    A definitive diagnosis of urothelial carcinoma in urine cytology is often challenging and subjective. Many urine cytology samples receive an indeterminate diagnosis. Ancillary techniques such as fluorescence in situ hybridization (FISH) have been used to improve the diagnostic sensitivity, but FISH is not approved as a routine screening test, and the complex fluorescent staining protocol also limits its widespread clinical use. Quantitative phase imaging (QPI) is an emerging technology allowing accurate measurements of the single-cell dry mass. This study was undertaken to explore the ability of QPI to improve the diagnostic accuracy of urine cytology for malignancy. QPI was performed on unstained, ThinPrep-prepared urine cytology slides from 28 patients with 4 categories of cytological diagnoses (negative, atypical, suspicious, and positive for malignancy). The nuclear/cell dry mass, the entropy, and the nucleus-to-cell mass ratio were calculated for several hundred cells for each patient, and they were then correlated with the follow-up diagnoses. The nuclear mass and nuclear mass entropy of urothelial cells showed significant differences between negative and positive groups. These data showed a progressive increase from patients with negative diagnosis, to patients with atypical/suspicious and positive cytologic diagnosis. Most importantly, among the patients in the atypical and suspicious diagnosis, the nuclear mass and its entropy were significantly higher for those patients with a follow-up diagnosis of malignancy than those patients without a subsequent follow-up diagnosis of malignancy. QPI shows potential for improving the diagnostic accuracy of urine cytology, especially for indeterminate cases, and should be further evaluated as an ancillary test for urine cytology. Cancer Cytopathol 2016;124:641-50. © 2016 American Cancer Society. © 2016 American Cancer Society.

  14. Direct urine polymerase chain reaction for chlamydia and gonorrhoea: a simple means of bringing high-throughput rapid testing to remote settings?

    PubMed

    Rahimi, Frashta; Goire, Namraj; Guy, Rebecca; Kaldor, John M; Ward, James; Nissen, Michael D; Sloots, Theo P; Whiley, David M

    2013-08-01

    Background Rapid point-of-care tests (POCTs) for chlamydia (Chlamydia trachomatis) and gonorrhoea (Neisseria gonorrhoeae) have the potential to confer health benefits in certain populations even at moderate sensitivities; however, suitable POCTs for these organisms are currently lacking. In this study, we investigated the use of direct urine polymerase chain reaction (PCR), with the view of implementing a simplified PCR strategy for high-throughput chlamydia and gonorrhoea screening in remote settings. Briefly, a simple dilution of the urine was performed before adding it directly to a real-time PCR reaction. The method was evaluated using 134 stored urine specimens that had been submitted for chlamydia and gonorrhoea testing and had been tested using a commercial C. trachomatis and N. gonorrhoeae PCR method. These included samples that were PCR-positive for chlamydia (n=87), gonorrhoea (n=16) or both (n=2). Direct urine testing was conducted using previously described in-house real-time PCR methods for C. trachomatis and N. gonorrhoeae as well as for recognised N.gonorrhoeae antimicrobial resistance mechanisms. The overall sensitivities and specificities of the direct urine PCR were 78% and 100% for chlamydia, and 83% and 100% for gonorrhoea. N.gonorrhoeae penicillin and quinolone resistance mechanisms were characterised in 14 of the 18 N. gonorrhoeae-positive samples. The results of this study show that the simplified PCR strategy may be a feasible approach for rapid screening and improving chlamydia and gonorrhoea treatment in remote settings.

  15. Development and validation of a rapid turboflow LC-MS/MS method for the quantification of LSD and 2-oxo-3-hydroxy LSD in serum and urine samples of emergency toxicological cases.

    PubMed

    Dolder, Patrick C; Liechti, Matthias E; Rentsch, Katharina M

    2015-02-01

    Lysergic acid diethylamide (LSD) is a widely used recreational drug. The aim of the present study is to develop a quantitative turboflow LC-MS/MS method that can be used for rapid quantification of LSD and its main metabolite 2-oxo-3-hydroxy LSD (O-H-LSD) in serum and urine in emergency toxicological cases without time-consuming extraction steps. The method was developed on an ion-trap LC-MS/MS instrument coupled to a turbulent-flow extraction system. The validation data showed no significant matrix effects and no ion suppression has been observed in serum and urine. Mean intraday accuracy and precision for LSD were 101 and 6.84%, in urine samples and 97.40 and 5.89% in serum, respectively. For O-H-LSD, the respective values were 97.50 and 4.99% in urine and 107 and 4.70% in serum. Mean interday accuracy and precision for LSD were 100 and 8.26% in urine and 101 and 6.56% in serum, respectively. For O-H-LSD, the respective values were 101 and 8.11% in urine and 99.8 and 8.35% in serum, respectively. The lower limit of quantification for LSD was determined to be 0.1 ng/ml. LSD concentrations in serum were expected to be up to 8 ng/ml. 2-Oxo-3-hydroxy LSD concentrations in urine up to 250 ng/ml. The new method was accurate and precise in the range of expected serum and urine concentrations in patients with a suspected LSD intoxication. Until now, the method has been applied in five cases with suspected LSD intoxication where the intake of the drug has been verified four times with LSD concentrations in serum in the range of 1.80-14.70 ng/ml and once with a LSD concentration of 1.25 ng/ml in urine. In serum of two patients, the O-H-LSD concentration was determined to be 0.99 and 0.45 ng/ml. In the urine of a third patient, the O-H-LSD concentration was 9.70 ng/ml.

  16. Strategies for improving the collection of 24-hour urine for analysis in the clinical laboratory: redesigned instructions, opinion surveys, and application of reference change value to micturition.

    PubMed

    Tormo, Consuelo; Lumbreras, Blanca; Santos, Ana; Romero, Luis; Conca, Minerva

    2009-12-01

    -The preanalytic phase of 24-hour urine collection, before clinical analysis, requires the active participation of patients and usually takes place outside the laboratory. -We verify whether distribution of adequate information to health care personnel and patients will result in fewer preanalytic incidents. We also determine the intraindividual biologic variability associated with micturition and the corresponding reference change value (RCV). -The intervention provided training for 24-hour urine collection to the health care personnel of the 20th health district of the Valencian community in Spain. The preanalytic incidents related to 24-hour micturition were estimated before and after the intervention. An opinion survey on the problems involved in urine collection was also conducted among patients. The Harris formula was used to calculate the RCV. -Before the intervention, 130 preanalytic incidents were recorded (11.5%) and after the intervention, 76 (8.6%) (P = .04) were recorded. Of the 130 incidents recorded before the intervention, 63 (48.5%) involved omission to indicate the urine volume, and of the 76 incidents recorded after the intervention, only 1 (1.3%) (P < .001) involved this omission. Forty of 302 patients (13.2%) surveyed reported problems and more than half (175; 57.9%) had to collect various urine samples sequentially. The RCV determined was 54.5% for a percentage of variation in volume of 24-hour urine (PVVI) of 19.0 +/- 16.5%. Therefore, micturition associated with a PVVI >+/-54.5% suggests that 24-hour urine collection by the patient was incomplete. The results obtained when applying the RCV after the intervention showed that 6.3% of the 24-hour urine samples should be rejected. -The percentage of preanalytic incidents was reduced by providing health care personnel with information and training. The percentage of variation in volume of 24-hour urine can be used to evaluate the variation in patients' micturition. Reference change value was shown to be useful when determining whether 24-hour urine was properly collected.

  17. Diagnosis of neonatal group B Streptococcus sepsis by nested-PCR of residual urine samples

    PubMed Central

    Cezarino, Bruno Nicolino; Yamamoto, Lidia; Del Negro, Gilda Maria Barbaro; Rocha, Daisy; Okay, Thelma Suely

    2008-01-01

    Group B streptococcus (GBS) remains the most common cause of early-onset sepsis in newborns. Laboratory gold-standard, broth culture methods are highly specific, but lack sensitivity. The aim of this study was to validate a nested-PCR and to determine whether residue volumes of urine samples obtained by non invasive, non sterile methods could be used to confirm neonatal GBS sepsis. The nested-PCR was performed with primers of the major GBS surface antigen. Unavailability of biological samples to perform life supporting exams, as well as others to elucidate the etiology of infections is a frequent problem concerning newborn patients. Nevertheless, we decided to include cases according to strict criteria: newborns had to present with signs and symptoms compatible with GBS infection; at least one of the following biological samples had to be sent for culture: blood, urine, or cerebrospinal fluid; availability of residue volumes of the samples sent for cultures, or of others collected on the day of hospitalization, prior to antibiotic therapy prescription, to be analyzed by PCR; favorable outcome after GBS empiric treatment. In only one newborn GBS infection was confirmed by cultures, while infection was only presumptive in the other three patients (they fulfilled inclusion criteria but were GBS-culture negative). From a total of 12 biological samples (5 blood, 3 CSF and 4 urine specimen), eight were tested by culture methods (2/8 were positive), and 8 were tested by PCR (7/8 were positive), and only 4 samples were simultaneously tested by both methods (1 positive by culture and 3 by PCR). In conclusion, although based on a restricted number of neonates and samples, our results suggest that the proposed nested-PCR might be used to diagnose GBS sepsis as it has successfully amplified the three types of biological samples analyzed (blood, urine and cerebrospinal fluid), and was more sensitive than culture methods as PCR in urine confirmed diagnosis in all four patients. Moreover, PCR has enabled us to use residue volumes of urine samples collected by non invasive, non sterile methods, what is technically adequate as GBS is not part of the normal urine flora, thus avoiding invasive procedures such as suprapubic bladder punction or transurethral catheterization. At the same time, the use of urine instead of blood samples could help preventing newborns blood spoliation. PMID:24031170

  18. Exposure assessment approach through mycotoxin/creatinine ratio evaluation in urine by GC-MS/MS.

    PubMed

    Rodríguez-Carrasco, Yelko; Moltó, Juan Carlos; Mañes, Jordi; Berrada, Houda

    2014-10-01

    In this pilot survey human urine samples were analyzed for presence of 15 mycotoxins and some of their metabolites using a novel urinary multi-mycotoxin GC-MS/MS method following salting-out liquid-liquid extraction. Fifty-four urine samples from children and adults residents in Valencia were analyzed for presence of urinary mycotoxin and expressed in gram of creatinine. Three out of 15 mycotoxins were detected namely, HT-2 toxin, nivalenol and deoxynivalenol (DON). 37 samples showed quantifiable values of mycotoxins. Co-occurrence of these contaminants was also observed in 20.4% of assayed samples. DON was the most frequently detected mycotoxin (68.5%) with mean levels of 23.3 μg/g creatinine (range: 2.8-69.1 μg/g creatinine). The levels of urinary DON were used to carry out an exposure assessment approach. 8.1% of total subjects were estimated to exceed the DON provisional maximum tolerable daily intake (PMTDI) (1 μg/kg b.w.). Two out of 9 exposed children exceeded the DON PMTDI thus, making them the most exposed based on the urinary results. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Does the Exposure of Urine Samples to Air Affect Diagnostic Tests for Urine Acidification?

    PubMed Central

    Yi, Joo-Hark; Shin, Hyun-Jong; Kim, Sun-Moon; Han, Sang-Woong; Oh, Man-Seok

    2012-01-01

    Summary Background and objectives For accurate measurement of pH, urine collection under oil to limit the escape of CO2 on air exposure is recommended. This study aims to test the hypothesis that urine collection under oil is not necessary in acidic urine in which bicarbonate and CO2 are minor buffers, because loss of CO2 would have little effect on its pH. Design, setting, participants, & measurements One hundred consecutive random urine samples were collected under oil and analyzed for pH, pCO2, and HCO3− immediately and after 5 minutes of vigorous shaking in uncovered flasks to allow CO2 escape. Results The pH values in 97 unshaken samples ranged from 5.03 to 6.83. With shaking, urine pCO2 decreased by 76%, whereas urine HCO3− decreased by 60%. Meanwhile, urine baseline median pH (interquartile range) of 5.84 (5.44–6.25) increased to 5.93 (5.50–6.54) after shaking (ΔpH=0.12 [0.07–0.29], P<0.001). ΔpH with pH≤6.0 was significantly lower than the ΔpH with pH>6.0 (0.08 [0.05–0.12] versus 0.36 [0.23–0.51], P<0.001). Overall, the lower the baseline pH, the smaller the ΔpH. Conclusions The calculation of buffer reactions in a hypothetical acidic urine predicted a negligible effect on urine pH on loss of CO2 by air exposure, which was empirically proven by the experimental study. Therefore, exposure of urine to air does not substantially alter the results of diagnostic tests for urine acidification, and urine collection under oil is not necessary. PMID:22700881

  20. The Diagnostic Accuracy of Urine-Based Xpert MTB/RIF in HIV-Infected Hospitalized Patients Who Are Smear-Negative or Sputum Scarce

    PubMed Central

    Peter, Jonathan G.; Theron, Grant; Muchinga, Tapuwa E.; Govender, Ureshnie; Dheda, Keertan

    2012-01-01

    Background Hospitals in sub-Saharan Africa are inundated with HIV-infected patients and tuberculosis (TB) is the commonest opportunistic infection in this sub-group. Up to one third of TB-HIV co-infected patients fail to produce a sputum sample (sputum scarce) and diagnosis is thus often delayed or missed. We investigated the sensitivity of urine-based methods (Xpert MTB/RIF, LAM strip test and LAM ELISA) in such patients. Methodology/Principal Findings 281 HIV-infected hospitalised patients with clinically suspected TB provided a spot urine sample. The reference standard was culture positivity for Mycobacterium tuberculosis on ≥1 sputum or extra-pulmonary sample. MTB/RIF was performed using 1 ml of both unprocessed and, when possible, concentrated urine. Each unconcentrated urine sample was also tested using the Clearview LAM ELISA and Alere LAM strip test. 42% (116/242) of patients had culture-proven TB. 18% (20/54) were sputum scarce. In sputum-scarce patients, the sensitivity of urine MTB/RIF and LAM ELISA was 40% (95%CI: 22–61) and 60% (95%CI: 39–78), respectively. Urine MTB/RIF specificity was 98% (95%CI: 95–100). Combined sensitivity of urine LAM ELISA and MTB/RIF was better than MTB/RIF alone [MTB/RIF and LAM: 70% (95%CI: 48–85) vs. MTB/RIF: 40% (95%CI: 22–61), p = 0.03]. Significant predictors of urine MTB/RIF positivity were CD4<50 cells/ml (p = 0.001), elevated protein-to-creatinine ratio (p<0.001) and LAM ELISA positivity (p<0.001). Urine centrifugation and pelleting significantly increased the sensitivity of MTB/RIF over unprocessed urine in paired samples [42% (95%CI: 26–58) vs. 8% (95%CI: 0–16), p<0.001]. Urine MTB/RIF-generated CT values correlated poorly with markers of bacillary burden (smear grade and time-to-positivity). Conclusions/Significance This preliminary study indicates that urine-based MTB/RIF, alone or in combination with LAM antigen detection, may potentially aid the diagnosis of TB in HIV-infected patients with advanced immunosuppression when sputum-based diagnosis is not possible. Concentration of urine prior to MTB/RIF-testing significantly improves sensitivity. PMID:22815718

  1. Discordant genotyping results using DNA isolated from anti-doping control urine samples.

    PubMed

    Choong, Eva; Schulze, Jenny J; Ericsson, Magnus; Rane, Anders; Ekström, Lena

    2017-07-01

    The UGT2B17 gene deletion polymorphism is known to correlate to urinary concentration of testosterone-glucuronide and hence this genotype exerts a large impact on the testosterone/epitestosterone (T/E) ratio, a biomarker for testosterone doping. The objective of this study was to assess if DNA isolated from athletes' urine samples (n = 713) obtained in routine doping controls could be targeted for genotyping analysis for future integration in the athlete's passport. A control population (n = 21) including both urine and blood DNA was used for genotyping concordance test. Another aim was to study a large group (n = 596) of authentic elite athletes in respect of urinary steroid profile in relation to genetic variation. First we found that the genotype results when using urine-derived DNA did not correlate sufficiently with the genotype obtained from whole blood DNA. Secondly we found males with one or two UGT2B17 alleles had higher T/E (mean 1.63 ± 0.93) than females (mean 1.28 ± 1.08), p˂0.001. Unexpectedly, we found that several male del/del athletes in power sports had a T/E ˃1. If men in power sport exert a different urinary steroid profile needs to be further investigated. The other polymorphisms investigated in the CYP17A1, UGT2B7 and UGT2B15 genes did not show any associations with testosterone and epitestosterone concentrations. Our results show that genotyping using urine samples according to our method is not useful in an anti-doping setting. Instead, it is of importance for the anti-doping test programs to include baseline values in the ABP to minimize any putative impact of genotype. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  2. Reversion of High-level Mecillinam Resistance to Susceptibility in Escherichia coli During Growth in Urine.

    PubMed

    Thulin, Elisabeth; Thulin, Måns; Andersson, Dan I

    2017-09-01

    Mecillinam (amdinocillin) is a β-lactam antibiotic used to treat uncomplicated urinary tract infections (UTIs). We have previously shown that inactivation of the Escherichia coli cysB gene is the major cause of mecillinam resistance (Mec R ) in clinical isolates. In this study, we used different E. coli strains (laboratory and clinical isolates) that were Mec R due to cysB mutations to determine how mecillinam susceptibility was affected during growth in urine compared to growth in the commonly used growth medium Mueller Hinton (MHB). We also examined mecillinam susceptibility when bacteria were grown in urine obtained from 48 different healthy volunteers. Metabolome analysis was done on the urine samples and the association between the mecillinam susceptibility patterns of the bacteria and urine metabolite levels was studied. Two major findings with clinical significance are reported. First, Mec R E. coli cysB mutant strains (both laboratory and clinical isolates) were always more susceptible to mecillinam when grown in urine as compared to laboratory medium, with many strains showing complete phenotypic susceptibility in urine. Second, the degree of reversion to susceptibility varied between urine samples obtained from different individuals. This difference was correlated with osmolality such that in urine with low osmolality the Mec R mutants were more susceptible to mecillinam than in urine with high osmolality. This is the first example describing conditional resistance where a genetically stable antibiotic resistance can be phenotypically reverted to susceptibility by metabolites present in urine. These findings have several important clinical implications regarding the use of mecillinam to treat UTIs. First, they suggest that mecillinam can be used to treat also those clinical strains that are identified as Mec R in standard laboratory tests. Second, the results suggest that testing of mecillinam susceptibility in the laboratory ought to be performed in media that mimics urine to obtain clinically relevant susceptibility testing results. Third, these findings imply that changes in patient behavior, such as increased water intake or use of diuretics to reduce urine osmolality and increased intake of cysteine, might induce antibiotic susceptibility in an infecting Mec R E. coli strain and thereby increase treatment efficiency. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  3. Use of illicit drugs by truck drivers arriving at Paranaguá port terminal, Brazil.

    PubMed

    Peixe, Tiago Severo; de Almeida, Rafael Menck; Girotto, Edmarlon; de Andrade, Selma Maffei; Mesas, Arthur Eumann

    2014-01-01

    The purpose of this study was to estimate the prevalence of recent use of illicit drugs among truck drivers who had parked their vehicles at the terminal port in Paranaguá City at Paraná State, southern Brazil. This cross-sectional study was part of a larger research project conducted among drivers at a regional Brazilian port. Data on professional characteristics, involvement in road traffic injuries, sleep, and use of alcohol and illicit drugs were collected using a questionnaire. Urine samples were collected and analyzed for amphetamines, cocaine, and cannabis using gas chromatography with mass spectrometric detection. Sixty-two drivers were included in the study. Toxicological analyses showed that 8.1 percent (95% confidence interval [CI], 2.7-17.8%) of the urine samples were positive for drugs (4.8% for cocaine, 1.6% for amphetamine, and 1.6% for both); 8.1 percent reported drug use during the preceding 30 days in the questionnaire and only one tested positive for the drug in the urine sample. No sample was positive for cannabinoids. In total, at least 14.5 percent (95% CI, 6.9-25.8%) had used illicit drugs during the preceding 30 days based on self-reports and urine testing. Drivers who reported involvement in traffic injuries the year before more often tested positive for drugs in biological samples (P <.05). This research provides preliminary evidence that the use of illicit stimulants was common among professional truck drivers transporting grain loads. Thus, actions are needed to reduce drug use among truck drivers in order to prevent drug-related road traffic injuries.

  4. Direct trace-elemental analysis of urine samples by laser ablation-inductively coupled plasma mass spectrometry after sample deposition on clinical filter papers.

    PubMed

    Aramendía, Maite; Rello, Luis; Vanhaecke, Frank; Resano, Martín

    2012-10-16

    Collection of biological fluids on clinical filter papers shows important advantages from a logistic point of view, although analysis of these specimens is far from straightforward. Concerning urine analysis, and particularly when direct trace elemental analysis by laser ablation-inductively coupled plasma mass spectrometry (LA-ICPMS) is aimed at, several problems arise, such as lack of sensitivity or different distribution of the analytes on the filter paper, rendering obtaining reliable quantitative results quite difficult. In this paper, a novel approach for urine collection is proposed, which circumvents many of these problems. This methodology consists on the use of precut filter paper discs where large amounts of sample can be retained upon a single deposition. This provides higher amounts of the target analytes and, thus, sufficient sensitivity, and allows addition of an adequate internal standard at the clinical lab prior to analysis, therefore making it suitable for a strategy based on unsupervised sample collection and ulterior analysis at referral centers. On the basis of this sampling methodology, an analytical method was developed for the direct determination of several elements in urine (Be, Bi, Cd, Co, Cu, Ni, Sb, Sn, Tl, Pb, and V) at the low μg L(-1) level by means of LA-ICPMS. The method developed provides good results in terms of accuracy and LODs (≤1 μg L(-1) for most of the analytes tested), with a precision in the range of 15%, fit-for-purpose for clinical control analysis.

  5. Real-Time Polymerase Chain Reaction for Detection of Schistosoma DNA in Small-Volume Urine Samples Reflects Focal Distribution of Urogenital Schistosomiasis in Primary School Girls in KwaZulu Natal, South Africa

    PubMed Central

    Pillay, Pavitra; Taylor, Myra; Zulu, Siphosenkosi G.; Gundersen, Svein G.; Verweij, Jaco J.; Hoekstra, Pytsje; Brienen, Eric A. T.; Kleppa, Elisabeth; Kjetland, Eyrun F.; van Lieshout, Lisette

    2014-01-01

    Schistosoma haematobium eggs and Schistosoma DNA levels were measured in urine samples from 708 girls recruited from 18 randomly sampled primary schools in South Africa. Microscopic analysis of two 10-mL urine subsamples collected on three consecutive days confirmed high day-to-day variation; 103 (14.5%) girls had positive results at all six examinations, and at least one positive sample was seen in 225 (31.8%) girls. Schistosoma-specific DNA, which was measured in a 200-μL urine subsample by using real-time polymerase chain reaction, was detected in 180 (25.4%) cases, and levels of DNA corresponded significantly with average urine egg excretion. In concordance with microscopic results, polymerase chain reaction results were significantly associated with history of gynecologic symptoms and confirmed highly focal distribution of urogenital schistosomiasis. Parasite-specific DNA detection has a sensitivity comparable to single urine microscopy and could be used as a standardized high-throughput procedure to assess distribution of urogenital schistosomiasis in relatively large study populations by using small sample volumes. PMID:24470560

  6. Development of Technologies for Early Detection and Stratification of Breast Cancer

    DTIC Science & Technology

    2014-10-01

    cancer. Similar screening has been done in urine samples with CYR61 and LCN2 (Figure 2a-b). The Moses lab provided breast cancer urine samples and two ...diseased samples, while CYR61 appears to have two different populations whereas diseased urine samples have lower levels of the protein present. More... system for eDAR so that each isolated cell can be deposited into a well of a 96-well plate for high-throughput downstream single-cell digital

  7. Molecular identification of drug resistant mutations to tetracycline in Mycoplasma spp. isolated from patients with multiple sclerosis.

    PubMed

    Naghib, M; Kheirkhah, B; Mohebbi, R; Sadeg, L

    2017-08-15

    Bacterial infections play a significant role in causing or intensifying the attacks in MS and there are reports based on the interference of Mycoplasma with a global distribution. Mycoplasma causes autoimmune attacks by imitating the host cell membrane, which is a way of resistance to antibiotics. The purpose of this study was to evaluate the molecular identification of mutations causing resistance to tetracycline in Mycoplasma isolated from MS patients. A total number of 32 cerebrospinal fluid samples and 48 urinal fluid samples were collected from MS patients. The samples were enriched in 7 PPLO broth for one night and continuous cultivation in agar PPLO and PPLO broth for one week. DNA was extracted, and then nested PCR and Doublex PCR were used for bacteria genus identification and the presence of potential tetracycline-resistant alleles (rrs4 and rrs3), respectively.  A total number of 12 samples created colonies. However, only 5 samples (1 cerebrospinal fluid and 4 urinal samples) were detected to be Mycoplasma. The urinal samples showed the desired alleles and were tetracycline-resistant. By sequencing the PCR products, it was shown that these alleles have mutated in various points. Based on the results it seems that the resistant mutated Mycoplasma can be detected in MS patients in our population and may be considered as a risk factor for the disease.

  8. DNA typing for personal identification of urine after long-term preservation for testing in doping control.

    PubMed

    Aoki, Kimiko; Tanaka, Hiroyuki; Ueki, Makoto

    2017-08-01

    When the tampering of a urine sample is suspected in doping control, personal identification of the sample needs to be determined by short tandem repeat (STR) analysis using DNA. We established a method for extracting DNA from urine samples stored at -20 °C without using any additives or procedures, which is consistent with how samples are required to be managed for doping control. The method, using the Puregene® Blood Core kit followed by NucleoSpin® gDNA Clean-up or NucleoSpin® gDNA Clean-up XS kit, does not need any special instrument and can provide a purified extract with high-quality DNA from up to 40 mL of urine suitable for STR analysis using an AmpFlSTR® Identifiler® PCR amplification kit. Storing urine at -20 °C is detrimental to the stability of DNA. The DNA concentration of preserved urine could not be predicted by specific gravity or creatinine level at the time of urine collection. The DNA concentration of a purified extract (10 μL) was required to be >0.06 ng/μL to ensure a successful STR analysis. Thus, the required extraction volumes of urine preserved for 3-7 years at -20 °C were estimated to be 30 mL and 20 mL to succeed in at least 86% of men and 91% of women, respectively. Considering the long half-life of DNA during long-term preservation, our extraction method is applicable to urine samples stored even for 10 years, which is currently the storage duration allowed (increased from 8 years) before re-examination in doping control. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  9. Studies on acid-base status (Stewart's model) of young camels (Camelus dromedarius) after acid-load with NH4Cl.

    PubMed

    Elkhair, Nawal M; Hartmann, Helmut

    2010-01-01

    The identification of the reference values of Stewart variables and the changes in the acid-base status of the blood and urine in relation to the age after acid-load were studied in desert species of camels. 14 healthy young camels (age: 3-5 months) and 22 adult camels (age: 5-8 years) were used to provide the reference and percentile ranges of the Stewart variables. In the experiments, 24 healthy young camels (age: < 3-5 months) were infused with 5M NH4Cl solution (dose: 1.0 ml/kg) through a permanent intravenous catheter. Venous blood and urine samples were collected before infusion (0 hours). After the start of infusion, venous blood samples were collected at 2, 4, 6, 8 and 24 hours, and urine samples were collected at 8, 24 and 48 hours. Blood and urine samples were used for the determination of the various acid-base parameters, including the non-respiratory Stewart variables. The reference range of serum-[strong ion difference = SID3] was 39-52 mmol/l for all age groups. The reference values of serum-[acid total = A-] were between 10-17 mmol/l for all age groups. Serum-[Atotprotein] and -[Atot-albumin] showed a reference range of 19-24 mmol/I and 20-28 mmol/l, respectively. By 2-8 hours after the NH4Cl-load, the Stewart variables (serum-[SID3] and serum-[A(tot-protein)]) decreased significantly, and as a consequence, the blood pH decreased. Generally, the loaded young camels showed a transient moderate hyperchloraemic acidosis with a slight hypoproteinaemic alkalosis. These malfunctions were accompanied by increased renal fractional excretion of chloride and sodium and decreased urine pH. The identified reference values of the Stewart variables can be used for the clinical diagnosis of acid-base disturbances in camels. With the assistance of the non-respiratory Stewart variables ([SID3] and [Atot]), we can detect the determining influence of strong electrolytes (Na+, K+ and Cl-) and weak acids (proteins, Pi) on the physiological and pathological acid-base status of the animals.

  10. Urine benzodiazepines screening of involuntarily drugged and robbed or raped patients.

    PubMed

    Boussairi, A; Dupeyron, J P; Hernandez, B; Delaitre, D; Beugnet, L; Espinoza, P; Diamant-Berger, O

    1996-01-01

    This study involved 35 patients who claimed to have been drugged before being robbed or raped, despite urine negative toxicologic screening by immunoenzymatic methods. The urines were frozen for further investigations, including enzymatic hydrolysis of urinary conjugates, liquid-solid extraction and, finally, immunoenzymatic screening of concentrated urine extract. Urine benzodiazepines were analyzed by immunoenzymatic assay before and after enzymatic hydrolysis combined with extraction. On direct immunoenzymatic screening, 17 of the 35 urine samples were benzodiazepine positive. Enrichment of preserved specimens improved the detection threshold from 200 ng/mL to 50 ng/mL and 10 of the 18 negative urines became positive. This method allowed us to demonstrate the benzodiazepines in half of previously negative urine samples. Benzodiazepine screening is particularly problematic because of low dosage, rapid elimination, failure to detect conjugated metabolites by immunoenzymatic reagents and high threshold of sensitivity for certain substances.

  11. Microanalyzer for Biomonitoring of Lead (Pb) in Blood and Urine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yantasee, Wassana; Timchalk, Chuck; Lin, Yuehe

    2007-01-01

    Biomonitoring of lead (Pb) in blood and urine enables quantitative evaluation of human occupational and environmental exposures to Pb. The state-of-the-art ICP-MS instruments analyze metals in laboratories, resulting in lengthy turn around time, and are expensive. In response to the growing need for metal analyzer for on-site, real-time monitoring of trace metals in individuals, we developed a portable microanalyzer based on flow-injection/adsorptive stripping voltammetry and used it to analyze Pb in rat blood and urine. Fouling of electrodes by proteins often prevents the effective use of electrochemical sensors in biological matrices. Minimization of such fouling was accomplished with the suitablemore » sample pretreatment and the turbulent flowing of Pb contained blood and urine onto the glassy electrode inside the microanalyzer, which resulted in no apparent electrode fouling even when the samples contained 50% urine or 10% blood by volume. There was no matrix effect on the voltammetric Pb signals even when the samples contained 10% blood or 10% urine. The microanalyzer offered linear concentration range relevant to Pb exposure levels in human (0-20 ppb in 10%-blood samples, 0-50 ppb in 50%-urine samples). The device had excellent sensitivity and reproducibility; Pb detection limits were 0.54 ppb and 0.42 ppb, and % RSDs were 4.9 and 2.4 in 50%-urine and 10%-blood samples, respectively. It offered a high throughput (3 min per sample) and had economical use of samples (60 ?L per measurement), making the collection of blood being less invasive especially to children, and had low reagent consumption (1 ?g of Hg per measurement), thus minimizing the health concerns of mercury use. Being miniaturized in size, the microanalyzer is portable and field-deployable. Thus, it has a great potential to be the next-generation analyzer for biomonitoring of toxic metals.« less

  12. Optimizing Urine Processing Protocols for Protein and Metabolite Detection.

    PubMed

    Siddiqui, Nazema Y; DuBois, Laura G; St John-Williams, Lisa; Will, Thompson J; Grenier, Carole; Burke, Emily; Fraser, Matthew O; Amundsen, Cindy L; Murphy, Susan K

    In urine, factors such as timing of voids, and duration at room temperature (RT) may affect the quality of recovered protein and metabolite data. Additives may aid with detection, but can add more complexity in sample collection or analysis. We aimed to identify the optimal urine processing protocol for clinically-obtained urine samples that allows for the highest protein and metabolite yields with minimal degradation. Healthy women provided multiple urine samples during the same day. Women collected their first morning (1 st AM) void and another "random void". Random voids were aliquotted with: 1) no additive; 2) boric acid (BA); 3) protease inhibitor (PI); or 4) both BA + PI. Of these aliquots, some were immediately stored at 4°C, and some were left at RT for 4 hours. Proteins and individual metabolites were quantified, normalized to creatinine concentrations, and compared across processing conditions. Sample pools corresponding to each processing condition were analyzed using mass spectrometry to assess protein degradation. Ten Caucasian women between 35-65 years of age provided paired 1 st morning and random voided urine samples. Normalized protein concentrations were slightly higher in 1 st AM compared to random "spot" voids. The addition of BA did not significantly change proteins, while PI significantly improved normalized protein concentrations, regardless of whether samples were immediately cooled or left at RT for 4 hours. In pooled samples, there were minimal differences in protein degradation under the various conditions we tested. In metabolite analyses, there were significant differences in individual amino acids based on the timing of the void. For comparative translational research using urine, information about void timing should be collected and standardized. For urine samples processed in the same day, BA does not appear to be necessary while the addition of PI enhances protein yields, regardless of 4°C or RT storage temperature.

  13. Integrated preservation and sample clean up procedures for studying water ingestion by recreational swimmers via urinary biomarker determination.

    PubMed

    Cantú, Ricardo; Shoemaker, Jody A; Kelty, Catherine A; Wymer, Larry J; Behymer, Thomas D; Dufour, Alfred P; Magnuson, Matthew L

    2017-08-22

    The use of cyanuric acid as a biomarker for ingestion of swimming pool water may lead to quantitative knowledge of the volume of water ingested during swimming, contributing to a better understanding of disease resulting from ingestion of environmental contaminants. When swimming pool water containing chlorinated cyanurates is inadvertently ingested, cyanuric acid is excreted quantitatively within 24 h as a urinary biomarker of ingestion. Because the volume of water ingested can be quantitatively estimated by calculation from the concentration of cyanuric acid in 24 h urine samples, a procedure for preservation, cleanup, and analysis of cyanuric acid was developed to meet the logistical demands of large scale studies. From a practical stand point, urine collected from swimmers cannot be analyzed immediately, given requirements of sample collection, shipping, handling, etc. Thus, to maintain quality control to allow confidence in the results, it is necessary to preserve the samples in a manner that ensures as quantitative analysis as possible. The preservation and clean-up of cyanuric acid in urine is complicated because typical approaches often are incompatible with the keto-enol tautomerization of cyanuric acid, interfering with cyanuric acid sample preparation, chromatography, and detection. Therefore, this paper presents a novel integration of sample preservation, clean-up, chromatography, and detection to determine cyanuric acid in 24 h urine samples. Fortification of urine with cyanuric acid (0.3-3.0 mg/L) demonstrated accuracy (86-93% recovery) and high reproducibility (RSD < 7%). Holding time studies in unpreserved urine suggested sufficient cyanuric acid stability for sample collection procedures, while longer holding times suggested instability of the unpreserved urine. Preserved urine exhibited a loss of around 0.5% after 22 days at refrigerated storage conditions of 4 °C. Published by Elsevier B.V.

  14. Diagnosis and effects of urine contamination in cooled-extended stallion semen.

    PubMed

    Ellerbrock, R; Canisso, I; Feijo, L; Lima, F; Shipley, C; Kline, K

    2016-04-15

    Urospermia is known to affect semen quality in many mammals, including stallions. Determinations of semen pH and creatinine and urea concentrations have been used to diagnose urine contamination in raw stallion semen. Unfortunately, practitioners suspecting urine contamination in cooled-shipped samples have no proven means to confirm the presence of urine. Therefore, the objectives of this study were (1) to assess the effects of urine contamination on sperm motility of extended fresh and cooled-stored stallion semen, (2) to evaluate the usefulness of semen color, odor, pH, and creatinine and urea concentrations for urospermia diagnosis, and (3) to evaluate the accuracy of a commercial blood urea nitrogen test strip in diagnosing urine contamination in extended-cooled stallion semen. Thirty-seven ejaculates were obtained from 11 stallions with no history of urospermia before division into 5 mL aliquots, and contamination with stallion urine. Each resulting sample was assessed for sperm motility, color, odor, pH, creatinine, and urea nitrogen concentration using both a semiquantitative test strip (Azostix), and a quantitative automated analyzer before and after cooling for 24 hour. Sperm motility parameters, pH, and creatinine and urea concentrations were analyzed using mixed models. Urine contamination decreased total and progressive motility in all samples before and after cooling (P < 0.05). Mean control total motility was 80% at 0 hour and 67% at 24 hours, whereas urine-contaminated samples ranged from 30% to 71% at 0 hour and 27% to 61% at 24 hours. Control mean urea (29 mg/dL) and creatinine (0.6 mg/dL) concentrations were significantly different (P < 0.05) from all urine-contaminated samples (158 mg/dL and 11.6 mg/dL, respectively) at 0 hour. Similarly, control mean urea (8 mg/dL) and creatinine (0.9 mg/dL) concentrations were significantly different than all urine-contaminated samples at 24 hours. Odor assessment presented moderate sensitivity (65%) and high specificity (100%), while color assessment presented low sensitivity (47%) and moderate specificity (79%) for urine in extended semen. Azostix strips were highly sensitive (95%) and specific (97%). Assessment of color, odor, and pH are not reliable methods to diagnose urine in experimentally contaminated cooled-stored stallion semen. Sperm motility parameters (in raw and cooled semen) are significantly reduced by the presence of urine in a concentration dependent. The results of the present study indicated that determination of urea and creatinine concentrations can be used to diagnose urospermia and that Azostix can be used as a point care method for diagnosing urine contamination in extended cooled stallion semen. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Fully automated methods for the determination of hydrochlorothiazide in human plasma and urine.

    PubMed

    Hsieh, J Y; Lin, C; Matuszewski, B K; Dobrinska, M R

    1994-12-01

    LC assays utilizing fully automated sample preparation procedures on Zymark PyTechnology Robot and BenchMate Workstation for the quantification of hydrochlorothiazide (HCTZ) in human plasma and urine have been developed. After aliquoting plasma and urine samples, and adding internal standard (IS) manually, the robot executed buffer and organic solvent addition, liquid-liquid extraction, solvent evaporation and on-line LC injection steps for plasma samples, whereas, BenchMate performed buffer and organic solvent addition, liquid-liquid and solid-phase extractions, and on-line LC injection steps for urine samples. Chromatographic separations were carried out on Beckman Octyl Ultrasphere column using the mobile phase composed of 12% (v/v) acetonitrile and 88% of either an ion-pairing reagent (plasma) or 0.1% trifluoroacetic acid (urine). The eluent from the column was monitored with UV detector (271 nm). Peak heights for HCTZ and IS were automatically processed using a PE-Nelson ACCESS*CHROM laboratory automation system. The assays have been validated in the concentration range of 2-100 ng ml-1 in plasma and 0.1-20 micrograms ml-1 in urine. Both plasma and urine assays have the sensitivity and specificity necessary to determine plasma and urine concentrations of HCTZ from low dose (6.25/12.5 mg) administration of HCTZ to human subjects in the presence or absence of losartan.

  16. Combined quantification of paclitaxel, docetaxel and ritonavir in human feces and urine using LC-MS/MS.

    PubMed

    Hendrikx, Jeroen J M A; Rosing, Hilde; Schinkel, Alfred H; Schellens, Jan H M; Beijnen, Jos H

    2014-02-01

    A combined assay for the determination of paclitaxel, docetaxel and ritonavir in human feces and urine is described. The drugs were extracted from 200 μL urine or 50 mg feces followed by high-performance liquid chromatography analysis coupled with positive ionization electrospray tandem mass spectrometry. The validation program included calibration model, accuracy and precision, carry-over, dilution test, specificity and selectivity, matrix effect, recovery and stability. Acceptance criteria were according to US Food and Drug Administration guidelines on bioanalytical method validation. The validated range was 0.5-500 ng/mL for paclitaxel and docetaxel, 2-2000 ng/mL for ritonavir in urine, 2-2000 ng/mg for paclitaxel and docetaxel, and 8-8000 ng/mg for ritonavir in feces. Inter-assay accuracy and precision were tested for all analytes at four concentration levels and were within 8.5% and <10.2%, respectively, in both matrices. Recovery at three concentration levels was between 77 and 94% in feces samples and between 69 and 85% in urine samples. Method development, including feces homogenization and spiking blank urine samples, are discussed. We demonstrated that each of the applied drugs could be quantified successfully in urine and feces using the described assay. The method was successfully applied for quantification of the analytes in feces and urine samples of patients. Copyright © 2013 John Wiley & Sons, Ltd.

  17. Improved bacterial identification directly from urine samples with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

    PubMed

    Kitagawa, Koichi; Shigemura, Katsumi; Onuma, Ken-Ichiro; Nishida, Masako; Fujiwara, Mayu; Kobayashi, Saori; Yamasaki, Mika; Nakamura, Tatsuya; Yamamichi, Fukashi; Shirakawa, Toshiro; Tokimatsu, Issei; Fujisawa, Masato

    2018-03-01

    Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) contributes to rapid identification of pathogens in the clinic but has not yet performed especially well for Gram-positive cocci (GPC) causing complicated urinary tract infection (UTI). The goal of this study was to investigate the possible clinical use of MALDI-TOF MS as a rapid method for bacterial identification directly from urine in complicated UTI. MALDI-TOF MS was applied to urine samples gathered from 142 suspected complicated UTI patients in 2015-2017. We modified the standard procedure (Method 1) for sample preparation by adding an initial 10 minutes of ultrasonication followed by centrifugation at 500 g for 1 minutes to remove debris such as epithelial cells and leukocytes from the urine (Method 2). In 133 urine culture-positive bacteria, the rate of corresponded with urine culture in GPC by MALDI-TOF MS in urine with standard sample preparation (Method 1) was 16.7%, but the modified sample preparation (Method 2) significantly improved that rate to 52.2% (P=.045). Method 2 also improved the identification accuracy for Gram-negative rods (GNR) from 77.1% to 94.2% (P=.022). The modified Method 2 significantly improved the average MALDI score from 1.408±0.153 to 2.166±0.045 (P=.000) for GPC and slightly improved the score from 2.107±0.061 to 2.164±0.037 for GNR. The modified sample preparation for MALDI-TOF MS can improve identification accuracy for complicated UTI causative bacteria. This simple modification offers a rapid and accurate routine diagnosis for UTI, and may possibly be a substitute for urine cultures. © 2017 Wiley Periodicals, Inc.

  18. Interlaboratory trial for the measurement of total cobalt in equine urine and plasma by ICP-MS.

    PubMed

    Popot, Marie-Agnes; Ho, Emmie N M; Stojiljkovic, Natali; Bagilet, Florian; Remy, Pierre; Maciejewski, Pascal; Loup, Benoit; Chan, George H M; Hargrave, Sabine; Arthur, Rick M; Russo, Charlie; White, James; Hincks, Pamela; Pearce, Clive; Ganio, George; Zahra, Paul; Batty, David; Jarrett, Mark; Brooks, Lydia; Prescott, Lise-Anne; Bailly-Chouriberry, Ludovic; Bonnaire, Yves; Wan, Terence S M

    2017-09-01

    Cobalt is an essential mineral micronutrient and is regularly present in equine nutritional and feed supplements. Therefore, cobalt is naturally present at low concentrations in biological samples. The administration of cobalt chloride is considered to be blood doping and is thus prohibited. To control the misuse of cobalt, it was mandatory to establish an international threshold for cobalt in plasma and/or in urine. To achieve this goal, an international collaboration, consisting of an interlaboratory comparison between 5 laboratories for the urine study and 8 laboratories for the plasma study, has been undertaken. Quantification of cobalt in the biological samples was performed by inductively coupled plasma-mass spectrometry (ICP-MS). Ring tests were based on the analysis of 5 urine samples supplemented at concentrations ranging from 5 up to 500 ng/mL and 5 plasma samples spiked at concentrations ranging from 0.5 up to 25 ng/mL. The results obtained from the different laboratories were collected, compiled, and compared to assess the reproducibility and robustness of cobalt quantification measurements. The statistical approach for the ring test for total cobalt in urine was based on the determination of percentage deviations from the calculated means, while robust statistics based on the calculated median were applied to the ring test for total cobalt in plasma. The inter-laboratory comparisons in urine and in plasma were successful so that 97.6% of the urine samples and 97.5% of the plasma samples gave satisfactory results. Threshold values for cobalt in plasma and urine were established from data only obtained by laboratories involved in the ring test. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  19. Determination of lipoic acid in human urine by capillary zone electrophoresis.

    PubMed

    Kubalczyk, Paweł; Głowacki, Rafał

    2017-07-01

    Fast, simple, and accurate CE method enabling determination of lipoic acid (LA) in human urine has been developed and validated. LA is a disulfide-containing natural compound absorbed from the organism's diet. Due to powerful antioxidant activity, LA has been used for prevention and treatment of various diseases and disorders, e.g. cardiovascular diseases, neurodegenerative disorders, and cancer. The proposed analytical procedure consists of liquid-liquid sample extraction, reduction of LA with tris(2-carboxyethyl)phosphine, derivatization with 1-benzyl-2-chloropyridinium bromide (BCPB) followed by field amplified sample injection stacking, capillary zone electrophoresis separation, and ultraviolet-absorbance detection of LA-BCPB derivative at 322 nm. Effective baseline electrophoretic separation was achieved within 6 min under the separation voltage of 20 kV (∼80 μA) using a standard fused-silica capillary (effective length 51.5 cm, 75 μm id) and BGE consisted of 0.05 mol/L borate buffer adjusted to pH 9. The experimentally determined limit of detection for LA in urine was 1.2 μmol/L. The calibration curve obtained for LA in urine showed linearity in the range 2.5-80 μmol/L, with R 2 0.9998. The relative standard deviation of the points of the calibration curve was lower than 10%. The analytical procedure was successfully applied to analysis of real urine samples from seven healthy volunteers who received single 100 mg dose of LA. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. BKV infection and hemorrhagic cystitis after allogeneic bone marrow transplant.

    PubMed

    Fioriti, D; Degener, A M; Mischitelli, M; Videtta, M; Arancio, A; Sica, S; Sora, F; Pietropaolo, V

    2005-01-01

    Hemorrhagic cystitis (HC) is a well-known complication after allogeneic bone marrow transplant (BMT) and can be related to adenovirus or human polyomavirus BK (BKV) infections. In this study a group of 20 patients after allogeneic BMT has been examined. BMT urine samples were analysed for the presence of Adenovirus and BKV DNAby means of polymerase chain reaction (PCR). 5/20 BMT patients developed HC after BMT. The presence of BKV DNA in urine samples was evident in 3/15 patients without HC and in 5/5 patients with HC. In 2/5 HC-patients the BKV DNA was not found after therapy with Cidofovir and Ribavirin. The search for adenovirus DNA in all samples was negative. The analysis of BKV non-coding control region (NCCR) isolated from urine samples revealed a structure very similar to the archetype in all samples. The RFLP (Restriction Fragment Length Polymorphism assay) showed the presence of BKV subtypes I and IV, with the prevalence of subtype I (4/5). This study supports the hypothesis that HC is mainly related to BKV rather than to adenovirus infection in BMT patients. Moreover, since BKV subtype I was predominant, it is reasonable to hypothesize that a specific BKV subtype could be associated with the development of HC.

  1. Automated biowaste sampling system urine subsystem operating model, part 1

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Mangialardi, J. K.; Rosen, F.

    1973-01-01

    The urine subsystem automatically provides for the collection, volume sensing, and sampling of urine from six subjects during space flight. Verification of the subsystem design was a primary objective of the current effort which was accomplished thru the detail design, fabrication, and verification testing of an operating model of the subsystem.

  2. Rapid screening of selective serotonin re-uptake inhibitors in urine samples using solid-phase microextraction gas chromatography-mass spectrometry.

    PubMed

    Salgado-Petinal, Carmen; Lamas, J Pablo; Garcia-Jares, Carmen; Llompart, Maria; Cela, Rafael

    2005-07-01

    In this paper a solid-phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS) method is proposed for a rapid analysis of some frequently prescribed selective serotonin re-uptake inhibitors (SSRI)-venlafaxine, fluvoxamine, mirtazapine, fluoxetine, citalopram, and sertraline-in urine samples. The SPME-based method enables simultaneous determination of the target SSRI after simple in-situ derivatization of some of the target compounds. Calibration curves in water and in urine were validated and statistically compared. This revealed the absence of matrix effect and, in consequence, the possibility of quantifying SSRI in urine samples by external water calibration. Intra-day and inter-day precision was satisfactory for all the target compounds (relative standard deviation, RSD, <14%) and the detection limits achieved were <0.4 ng mL(-1) urine. The time required for the SPME step and for GC analysis (30 min each) enables high throughput. The method was applied to real urine samples from different patients being treated with some of these pharmaceuticals. Some SSRI metabolites were also detected and tentatively identified.

  3. Major Odorants Released as Urinary Volatiles by Urinary Incontinent Patients

    PubMed Central

    Pandey, Sudhir Kumar; Kim, Ki-Hyun; Choi, Si On; Sa, In Young; Oh, Soo Yeon

    2013-01-01

    In this study, volatile urinary components were collected using three different types of samples from patients suffering from urinary incontinence (UI): (1) urine (A); (2) urine + non-used pad (B); and (3) urine + used pad (C). In addition, urine + non-used pad (D) samples from non-patients were also collected as a reference. The collection of urinary volatiles was conducted with the aid of a glass impinger-based mini-chamber method. Each of the four sample types (A through D) was placed in a glass impinger and incubated for 4 hours at 37 °C. Ultra pure air was then passed through the chamber, and volatile urine gas components were collected into Tedlar bags at the other end. These bag samples were then analyzed for a wide range of VOCs and major offensive odorants (e.g., reduced sulfur compounds (RSCs), carbonyls, trimethylamine (TMA), ammonia, etc.). Among the various odorants, sulfur compounds (methanethiol and hydrogen sulfide) and aldehydes (acetaldehyde, butylaldehyde, and isovaleraldehyde) were detected above odor threshold and predicted to contribute most effectively to odor intensity of urine incontinence. PMID:23823973

  4. [Sampling, storage and transport of biological materials collected from living and deceased subjects for determination of concentration levels of ethyl alcohol and similarly acting substances. A proposal of updating the blood and urine sampling protocol].

    PubMed

    Wiergowski, Marek; Reguła, Krystyna; Pieśniak, Dorota; Galer-Tatarowicz, Katarzyna; Szpiech, Beata; Jankowski, Zbigniew

    2007-01-01

    The present paper emphasizes the most common mistakes committed at the beginning of an analytical procedure. To shorten the time and decrease the cost of determinations of substances with similar to alcohol activity, it is postulated to introduce mass-scale screening analysis of saliva collected from a living subject at the site of the event, with all positive results confirmed in blood or urine samples. If no saliva sample is collected for toxicology, a urine sample, allowing for a stat fast screening analysis, and a blood sample, to confirm the result, should be ensured. Inappropriate storage of a blood sample in the tube without a preservative can cause sample spilling and its irretrievable loss. The authors propose updating the "Blood/urine sampling protocol", with the updated version to be introduced into practice following consultations and revisions.

  5. ECLSS Sustaining Compatibility Testing on Urine Processor Assembly Nonmetallic Materials for Reformulation of Pretreated Urine Solution

    NASA Technical Reports Server (NTRS)

    Wingard, C. D.

    2015-01-01

    On International Space Station (ISS), the Urine Processor Assembly (UPA) converts human urine and flush water into potable water. The urine is acid-pretreated primarily to control microbial growth. In recent years, the sulfuric acid (H2SO4) pretreatment was believed to be largely responsible for producing salt crystals capable of plugging filters in UPA components and significantly reducing the percentage of water recovery from urine. In 2012, ISS management decided to change the acid pretreatment for urine from sulfuric to phosphoric with the goal of eliminating or minimizing formation of salt crystals. In 2013-2014, as part of the qualification of the phosphoric acid (H3PO4) formulation, samples of 12 nonmetallic materials used in UPA components were immersed for up to one year in pretreated urine and brine solutions made with the new H3PO4 formulation. Dynamic mechanical analysis (DMA) was used to measure modulus (stiffness) of the immersed samples compared to virgin control samples. Such compatibility data obtained by DMA for the H3PO4-based solutions were compared to DMA data obtained for the H2SO4-based solutions in 2002-2003.

  6. Intra- and inter-individual variations of blood and urinary water-soluble vitamins in Japanese young adults consuming a semi-purified diet for 7 days.

    PubMed

    Shibata, Katsumi; Fukuwatari, Tsutomu; Watanabe, Toshiaki; Nishimuta, Mamoru

    2009-12-01

    We have previously reported the levels of water-soluble vitamins in the blood and urine of Japanese young adults. In the present paper, to assess the variations in these water-soluble vitamin markers during the above experiment, we comprehensively determined the intra- and inter-individual variations of blood and urinary water-soluble vitamins to exactly the same amount of water-soluble vitamin intakes in the same experiment. The blood samples before breakfast and the 24-h urine samples were periodically collected from Japanese college male (n=10) and female (n=10) students consuming a semi-purified diet with water-soluble vitamins based on Japanese Dietary Reference Intakes for 7 d, and the intra- and inter-individual variations of blood and urinary water-soluble vitamins or their metabolites in blood and urine samples after adaptation were calculated. Although urinary excretion of vitamin B(12) and vitamin C showed high intra-individual variations in both males and females, other urinary vitamins and all blood vitamins showed less than 20% of within-subject coefficients of variance in either male or female. Those showing more than 20% of between-subject coefficients of variances in both male and female were blood vitamin B(6), vitamin B(12) and folate levels, and urinary vitamin B(1), vitamin B(2), vitamin B(12), nicotinamide metabolites, pantothenic acid, biotin and vitamin C. These results showed that oral administration of constant of water-soluble vitamins generally decreased intra-individual variation, while individual differences in urinary vitamin excretion were observed.

  7. Flow meter urine testing: a practical proposition in patients attending for urodynamics?

    PubMed

    Hashim, Hashim; Abrams, Paul

    2006-05-01

    To find a practical way of detecting urinary tract infection (UTI) before invasive urodynamic testing, as UTIs after urodynamics are well documented, but there are no standard guidelines about when urine should be analysed before urodynamics. Before urodynamics all patients are asked to provide a free urine flow; the patient is then catheterized to obtain a catheter-specimen of urine that is tested for infection by a urine dipstick. If the dipstick is found positive for nitrites and/or leukocytes, the test is abandoned and the sample sent for microscopy, culture and sensitivity. In the present study, patients were asked to provide a free urine flow into the flowmeter as usual. Between patients, the flowmeter was washed with soap and water and dried, so that there would be no cross-contamination between patients' urine results. Urine was collected as usual and tested using a dipstick, the patient was then catheterized and another dipstick test done on the catheter specimen of urine (CSU), to compare results. Pairs of urine samples, when positive for nitrite were 100% consistent, and 89% of pairs positive for leukocytes were the same before and after catheterization. The remaining 11% (all women) of the positive leukocyte group had leukocytosis on testing the flowmeter urine but not on the CSU, possibly due to contamination from the vagina. Testing urine by dipstick in the sample from the flowmeter is a feasible option, thus saving the patient an inappropriate catheterization, with the risk of bacteraemia during urodynamics, and allowing the flowrate to be measured.

  8. Maintenance treatment for opioid dependence with slow-release oral morphine: a randomized cross-over, non-inferiority study versus methadone

    PubMed Central

    Beck, Thilo; Haasen, Christian; Verthein, Uwe; Walcher, Stephan; Schuler, Christoph; Backmund, Markus; Ruckes, Christian; Reimer, Jens

    2014-01-01

    Aims To compare the efficacy of slow-release oral morphine (SROM) and methadone as maintenance medication for opioid dependence in patients previously treated with methadone. Design Prospective, multiple-dose, open label, randomized, non-inferiority, cross-over study over two 11-week periods. Methadone treatment was switched to SROM with flexible dosing and vice versa according to period and sequence of treatment. Setting Fourteen out-patient addiction treatment centres in Switzerland and Germany. Participants Adults with opioid dependence in methadone maintenance programmes (dose ≥50 mg/day) for ≥26 weeks. Measurements The efficacy end-point was the proportion of heroin-positive urine samples per patient and period of treatment. Each week, two urine samples were collected, randomly selected and analysed for 6-monoacetyl-morphine and 6-acetylcodeine. Non-inferiority was concluded if the two-sided 95% confidence interval (CI) in the difference of proportions of positive urine samples was below the predefined boundary of 10%. Findings One hundred and fifty-seven patients fulfilled criteria to form the per protocol population. The proportion of heroin-positive urine samples under SROM treatment (0.20) was non-inferior to the proportion under methadone treatment (0.15) (least-squares mean difference 0.05; 95% CI = 0.02, 0.08; P > 0.01). The 95% CI fell within the 10% non-inferiority margin, confirming the non-inferiority of SROM to methadone. A dose-dependent effect was shown for SROM (i.e. decreasing proportions of heroin-positive urine samples with increasing SROM doses). Retention in treatment showed no significant differences between treatments (period 1/period 2: SROM: 88.7%/82.1%, methadone: 91.1%/88.0%; period 1: P = 0.50, period 2: P = 0.19). Overall, safety outcomes were similar between the two groups. Conclusions Slow-release oral morphine appears to be at least as effective as methadone in treating people with opioid use disorder. PMID:24304412

  9. Diagnostic accuracy and applicability of a PCR system for the detection of Schistosoma mansoni DNA in human urine samples from an endemic area.

    PubMed

    Enk, Martin Johannes; Oliveira e Silva, Guilherme; Rodrigues, Nilton Barnabé

    2012-01-01

    Schistosomiasis caused by Schistosoma mansoni, one of the most neglected human parasitoses in Latin America and Africa, is routinely confirmed by microscopic visualization of eggs in stool. The main limitation of this diagnostic approach is its lack of sensitivity in detecting individual low worm burdens and consequently data on infection rates in low transmission settings are little reliable. According to the scientific literature, PCR assays are characterized by high sensitivity and specificity in detecting parasite DNA in biological samples. A simple and cost effective extraction method for DNA of Schistosoma mansoni from urine samples in combination with a conventional PCR assay was developed and applied in an endemic area. This urine based PCR system was tested for diagnostic accuracy among a population of a small village in an endemic area, comparing it to a reference test composed of three different parasitological techniques. The diagnostic parameters revealed a sensitivity of 100%, a specificity of 91.20%, positive and negative predictive values of 86.25% and 100%, respectively, and a test accuracy of 94.33%. Further statistical analysis showed a k index of 0.8806, indicating an excellent agreement between the reference test and the PCR system. Data obtained from the mouse model indicate the infection can be detected one week after cercariae penetration, opening a new perspective for early detection and patient management during this stage of the disease. The data indicate that this innovative PCR system provides a simple to handle and robust diagnostic tool for the detection of S. mansoni DNA from urine samples and a promising approach to overcome the diagnostic obstacles in low transmission settings. Furthermore the principals of this molecular technique, based on the examination of human urine samples may be useful for the diagnosis of other neglected tropical diseases that can be detected by trans-renal DNA.

  10. The diagnostic significance of lactate dehydrogenase isoenzymes in urinary cytology.

    PubMed Central

    Nishikawa, A.; Tanaka, T.; Takeuchi, T.; Fujihiro, S.; Mori, H.

    1991-01-01

    Lactate dehydrogenase (LDH) isoenzyme distribution was examined in 106 urine samples being tested cytologically for evidence of bladder cancer; the samples were selected to have less than 20 leucocytes and erythrocytes per high power field and the LDH pattern determined by electrophoresis. The Papanicolaou stained-smears showed 68 negative, 17 suspicious and 21 positive. The LDH M-fraction of the urinary supernatant in cytologically positive cases was significantly greater than in negative cases, although the latter included a few false negative samples. Some of the false negatives gave positive results for the LDH M-fraction; these results suggest that the determination of LDH isoenzymes in the urine is useful in diagnosing urinary tract cancers, including early stage, and for follow-up of patients with bladder cancers after surgical resection. PMID:2039708

  11. Changes in urinary level and configuration ratio of D-lactic acid in patients with short bowel syndrome.

    PubMed

    Inoue, Yoshito; Shinka, Toshihiro; Ohse, Morimasa; Kohno, Miyuki; Konuma, Kunio; Ikawa, Hiromichi; Kuhara, Tomiko

    2007-08-01

    The present study showed that the D-lactic acid configuration ratio in the urine rose earlier than that in blood or the urinary or blood D-lactic acid levels upon disease onset, and that the D-lactic acid measurement in urine is more sensitive and useful than that in blood. As this result, a prediction of a D-lactic acidosis may be possible. To simplify the procedure for detecting D-lactic acid, we first showed a correlation between the D-lactic acid configuration ratio in urine and blood, indicating urine could be used. To separate the optical isomers of lactic acid, we simplified our previous procedure. For chiral recognition, we chose O-acetyl-(-)-menthylation and analyzed the samples under GC/MS by capillary gas chromatography on a DB-5 MS column. This procedure is less sensitive than the former method, but it is faster and simpler, requiring only one derivatization step. This method may be useful for predicting D-lactic acidosis in patients with short bowel syndrome.

  12. Measurement of glomerular filtration rate in the conscious rat.

    PubMed

    Pestel, Sabine; Krzykalla, Volker; Weckesser, Gerhard

    2007-01-01

    Glomerular filtration rate (GFR) is an important parameter for studying drug-induced impairments on renal function in rats. The GFR is calculated from the concentration of creatinine and blood urea nitrogen (BUN) in serum and in urine, respectively. Following current protocols serum and urine samples must be taken from the same animal. Thus, in order to determine time-dependent effects it is necessary to use for each time point one separated group of animals. We developed a statistical test which allows analyzing the GFR from two different groups of animals: one used for repeated serum and the other one used for repeated urine analysis. Serum and urine samples were taken from two different sets of rats which were otherwise treated identically, i.e. drug doses, routes of administration (per os or per inhalation) and tap water loading. For each dose group GFR mean, standard deviation and statistical analysis to identify differences between the dose groups were determined. After determination of the optimal time points for measurements, the effect on GFR of the three reference compounds, furosemide, hydrochlorothiazide and formoterol, was calculated. The results showed that the diuretic drugs furosemide and hydrochlorothiazide decreased the GFR and the antidiuretic drug formoterol increased the GFR, as counter regulation on urine loss or urine retention, respectively. A mathematical model and the corresponding algorithm were developed, which can be used to calculate the GFR, and to test for differences between groups from two separated sets of rats, one used for urine, and the other one for serum analysis. This new method has the potential to reduce the number of animals needed and to improve the quality of data generated from various groups of animals in renal function studies.

  13. The efficacy of semi-quantitative urine protein-to-creatinine (P/C) ratio for the detection of significant proteinuria in urine specimens in health screening settings.

    PubMed

    Chang, Chih-Chun; Su, Ming-Jang; Ho, Jung-Li; Tsai, Yu-Hui; Tsai, Wei-Ting; Lee, Shu-Jene; Yen, Tzung-Hai; Chu, Fang-Yeh

    2016-01-01

    Urine protein detection could be underestimated using the conventional dipstick method because of variations in urine aliquots. This study aimed to assess the efficacy of the semi-quantitative urine protein-to-creatinine (P/C) ratio compared with other laboratory methods. Random urine samples were requested from patients undergoing chronic kidney disease screening. Significant proteinuria was determined by the quantitative P/C ratio of at least 150 mg protein/g creatinine. The semi-quantitative P/C ratio, dipstick protein and quantitative protein concentrations were compared and analyzed. In the 2932 urine aliquots, 156 (5.3 %) urine samples were considered as diluted and 60 (39.2 %) were found as significant proteinuria. The semi-quantitative P/C ratio testing had the best sensitivity (70.0 %) and specificity (95.9 %) as well as the lowest underestimation rate (0.37 %) when compared to other laboratory methods in the study. In the semi-quantitative P/C ratio test, 19 (12.2 %) had positive, 52 (33.3 %) had diluted, and 85 (54.5 %) had negative results. Of those with positive results, 7 (36.8 %) were positive detected by traditional dipstick urine protein test, and 9 (47.4 %) were positive detected by quantitative urine protein test. Additionally, of those with diluted results, 25 (48.1 %) had significant proteinuria, and all were assigned as no significant proteinuria by both tests. The semi-quantitative urine P/C ratio is clinically applicable based on its better sensitivity and screening ability for significant proteinuria than other laboratory methods, particularly in diluted urine samples. To establish an effective strategy for CKD prevention, urine protein screening with semi-quantitative P/C ratio could be considered.

  14. Cross-reactivity of stimulants found in sports drug testing by two fluorescence polarization immunoassays.

    PubMed

    de la Torre, R; Badia, R; Gonzàlez, G; García, M; Pretel, M J; Farré, M; Segura, J

    1996-01-01

    We investigated the usefulness of immunological methods for presumptive detection of stimulants found in sports drug testing. The ingestion of substances that show no cross-reactivity in tests commercially available for the detection of amphetamines can produce positive results in the urine. Human metabolism contributes to the positive results of some urine samples when the parent compound does not cross-react with the antibodies of the assay. Urine samples from healthy volunteers given stimulants were tested by chromatographic methods and by two different fluorescence polarization immunoassays (FPIA) from Abbott Laboratories for the analysis of amphetamines. According to the results obtained, we classified stimulants into four groups: detectable stimulants that gave rise to amphetamine by human metabolism (group 1); detectable ephedrines and related compounds, appearing in the urine either as parent compounds or originated by metabolism (group 2); detectable stimulants that displayed actual cross-reactivity with amphetamine tests (group 3); and stimulants not detected by FPIA (group 4). Most of the true doping cases due to the ingestion of stimulants may be detected by FPIA. The specificity of the results may be increased by combining immunological assays with different antibodies.

  15. A study examining the bias of albumin and albumin/creatinine ratio measurements in urine.

    PubMed

    Jacobson, Beryl E; Seccombe, David W; Katayev, Alex; Levin, Adeera

    2015-10-01

    The objective of the study was to examine the bias of albumin and albumin/creatinine (ACR) measurements in urine. Pools of normal human urine were augmented with purified human serum albumin to generate a series of 12 samples covering the clinical range of interest for the measurement of ACR. Albumin and creatinine concentrations in these samples were analyzed three times on each of 3 days by 24 accredited laboratories in Canada and the USA. Reference values (RV) for albumin measurements were assigned by a liquid chromatography-tandem mass spectrometry (LC-MS/MS) comparative method and gravimetrically. Ten random urine samples (check samples) were analyzed as singlets and albumin and ACR values reported according to the routine practices of each laboratory. Augmented urine pools were shown to be commutable. Gravimetrically assigned target values were corrected for the presence of endogenous albumin using the LC-MS/MS comparative method. There was excellent agreement between the RVs as assigned by these two methods. All laboratory medians demonstrated a negative bias for the measurement of albumin in urine over the concentration range examined. The magnitude of this bias tended to decrease with increasing albumin concentrations. At baseline, only 10% of the patient ACR values met a performance limit of RV ± 15%. This increased to 84% and 86% following post-analytical correction for albumin and creatinine calibration bias, respectively. International organizations should take a leading role in the standardization of albumin measurements in urine. In the interim, accuracy based urine quality control samples may be used by clinical laboratories for monitoring the accuracy of their urinary albumin measurements.

  16. Mining the human urine proteome for monitoring renal transplant injury

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sigdel, Tara K.; Gao, Yuqian; He, Jintang

    The human urinary proteome reflects systemic and inherent renal injury perturbations and can be analyzed to harness specific biomarkers for different kidney transplant injury states. 396 unique urine samples were collected contemporaneously with an allograft biopsy from 396 unique kidney transplant recipients. Centralized, blinded histology on the graft was used to classify matched urine samples into categories of acute rejection (AR), chronic allograft nephropathy (CAN), BK virus nephritis (BKVN), and stable graft (STA). Liquid chromatography–mass spectrometry (LC-MS) based proteomics using iTRAQ based discovery (n=108) and global label-free LC-MS analyses of individual samples (n=137) for quantitative proteome assessment were used inmore » the discovery step. Selected reaction monitoring (SRM) was applied to identify and validate minimal urine protein/peptide biomarkers to accurately segregate organ injury causation and pathology on unique urine samples (n=151). A total of 958 proteins were initially quantified by iTRAQ, 87% of which were also identified among 1574 urine proteins detected in LC-MS validation. 103 urine proteins were significantly (p<0.05) perturbed in injury and enriched for humoral immunity, complement activation, and lymphocyte trafficking. A set of 131 peptides corresponding to 78 proteins were assessed by SRM for their significance in an independent sample cohort. A minimal set of 35 peptides mapping to 33 proteins, were modeled to segregate different injury groups (AUC =93% for AR, 99% for CAN, 83% for BKVN). Urinary proteome discovery and targeted validation identified urine protein fingerprints for non-invasive differentiation of kidney transplant injuries, thus opening the door for personalized immune risk assessment and therapy.« less

  17. Optimization of solid-phase extraction and liquid chromatography-tandem mass spectrometry for simultaneous determination of capilliposide B and its active metabolite in rat urine and feces: Overcoming nonspecific binding.

    PubMed

    Cheng, Zhongzhe; Zhou, Xing; Li, Wenyi; Hu, Bingying; Zhang, Yang; Xu, Yong; Zhang, Lin; Jiang, Hongliang

    2016-11-30

    Capilliposide B, a novel oleanane triterpenoid saponin isolated from Lysimachia capillipes Hemsl, showed significant anti-tumor activities in recent studies. To characterize the excretion of Capilliposide B, a reliable liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for simultaneous determination of Capilliposide B and its active metabolite, Capilliposide A in rat urine and feces. Sample preparation using a solid-phase extraction procedure was optimized by acidification of samples at various degrees, providing extensive sample clean-up with a high extraction recovery. In addition, rat urinary samples were pretreated with CHAPS, an anti-adsorptive agent, for overcoming nonspecific analytes adsorption during sample storage and process. The method validation was conducted over the curve range of 10.0-5000ng/ml for both analytes. The intra- and inter-day precision and accuracy of the QC samples showed ≤11.0% RSD and -10.4-12.8% relative error. The method was successfully applied to an excretion study of Capilliposide B following intravenous administration. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Preparation of a molecularly imprinted sensor based on quartz crystal microbalance for specific recognition of sialic acid in human urine.

    PubMed

    Qiu, Xiuzhen; Xu, Xian-Yan; Chen, Xuncai; Wu, Yiyong; Guo, Huishi

    2018-05-08

    A novel molecularly imprinted quartz crystal microbalance (QCM) sensor was successfully prepared for selective determination of sialic acid (SA) in human urine samples. To obtain the QCM sensor, we first modified the gold surface of the QCM chip by self-assembling of allylmercaptane to introduce polymerizable double bonds on the chip surface. Then, SA molecularly imprinted polymer (MIP) nanofilm was attached to the modified QCM chip surface. For comparison, we have also characterized the nonmodified and improved surfaces of the QCM sensor by using atomic force microscopy (AFM) and Fourier transform infrared (FTIR) spectroscopy. We then tested the selectivity and detection limit of the imprinted QCM sensor via a series of adsorption experiments. The results show a linear response in the range of 0.025-0.50 μmol L -1 for sialic acid. Moreover, the limit of detection (LOD) of the prepared imprinted QCM sensor was found to be 1.0 nmol L -1 for sialic acid, and high recovery values range from 87.6 to 108.5% with RSD < 8.7 (n = 5) for the spiked urine sample obtained. Overall, this work presents how a novel QCM sensor was developed and used to detect sialic acid in human urine samples. Graphical abstract Specific recognition of sialic acid by the MIP-QCM sensor system.

  19. Assessment of 1H NMR-based metabolomics analysis for normalization of urinary metals against creatinine.

    PubMed

    Cassiède, Marc; Nair, Sindhu; Dueck, Meghan; Mino, James; McKay, Ryan; Mercier, Pascal; Quémerais, Bernadette; Lacy, Paige

    2017-01-01

    Proton nuclear magnetic resonance ( 1 H NMR, or NMR) spectroscopy and inductively coupled plasma-mass spectrometry (ICP-MS) are commonly used for metabolomics and metal analysis in urine samples. However, creatinine quantification by NMR for the purpose of normalization of urinary metals has not been validated. We assessed the validity of using NMR analysis for creatinine quantification in human urine samples in order to allow normalization of urinary metal concentrations. NMR and ICP-MS techniques were used to measure metabolite and metal concentrations in urine samples from 10 healthy subjects. For metabolite analysis, two magnetic field strengths (600 and 700MHz) were utilized. In addition, creatinine concentrations were determined by using the Jaffe method. Creatinine levels were strongly correlated (R 2 =0.99) between NMR and Jaffe methods. The NMR spectra were deconvoluted with a target database containing 151 metabolites that are present in urine. A total of 50 metabolites showed good correlation (R 2 =0.7-1.0) at 600 and 700MHz. Metal concentrations determined after NMR-measured creatinine normalization were comparable to previous reports. NMR analysis provided robust urinary creatinine quantification, and was sufficient for normalization of urinary metal concentrations. We found that NMR-measured creatinine-normalized urinary metal concentrations in our control subjects were similar to general population levels in Canada and the United Kingdom. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Quantification of Modified Tyrosines in Healthy and Diabetic Human Urine using Liquid Chromatography/Tandem Mass Spectrometry.

    PubMed

    Kato, Yoji; Dozaki, Natsuko; Nakamura, Toshiyuki; Kitamoto, Noritoshi; Yoshida, Akihiro; Naito, Michitaka; Kitamura, Masayasu; Osawa, Toshihiko

    2009-01-01

    The quantification of urinary oxidized tyrosines, dityrosine (DiY), nitrotyrosine (NY), bromotyrosine (BrY), and dibromotyrosine (DiBrY), was accomplished by quadruple liquid chromatography-tandem mass spectrometry (LC/MS/MS). The sample was partially purified by solid phase extraction, and was then applied to the LC/MS/MS using multiple-reaction monitoring (MRM) methods. The analysis for the DiY quantification was done first. The residual samples were further butylated with n-butanol/HCl, and the other modified tyrosines were then quantified with isotopic dilution methods. MRM peaks of the modified tyrosines (DiY, NY, BrY, and DiBrY) from human urine were measured and the elution times coincided with the authentic and isotopic standards. The amounts of modified tyrosines in healthy human urine (n = 23) were 8.8 +/- 0.6 (DiY), 1.4 +/- 0.4 (NY), 3.8 +/- 0.3 (BrY), and 0.7 +/- 0.1 (DiBrY) micromol/mol of creatinine, respectively. A comparison of the modified tyrosines with urinary 8-oxo-deoxyguanosine, pentosidine, and N(epsilon)-(hexanoyl)lysine was also performed. Almost all products, except for NY, showed good correlations with each other. The amounts of the modified tyrosines (NY, BrY, and DiBrY) in the diabetic urine were higher than those in the urine from healthy people.

  1. Correlating the amount of urea, creatinine, and glucose in urine from patients with diabetes mellitus and hypertension with the risk of developing renal lesions by means of Raman spectroscopy and principal component analysis

    NASA Astrophysics Data System (ADS)

    Bispo, Jeyse Aliana Martins; de Sousa Vieira, Elzo Everton; Silveira, Landulfo; Fernandes, Adriana Barrinha

    2013-08-01

    Patients with diabetes mellitus and hypertension (HT) diseases are predisposed to kidney diseases. The objective of this study was to identify potential biomarkers in the urine of diabetic and hypertensive patients through Raman spectroscopy in order to predict the evolution to complications and kidney failure. Urine samples were collected from control subjects (CTR) and patients with diabetes and HT with no complications (lower risk, LR), high degree of complications (higher risk, HR), and doing blood dialysis (DI). Urine samples were stored frozen (-20°C) before spectral analysis. Raman spectra were obtained using a dispersive spectrometer (830-nm, 300-mW power, and 20-s accumulation). Spectra were then submitted to principal component analysis (PCA) followed by discriminant analysis. The first PCA loading vectors revealed spectral features of urea, creatinine, and glucose. It has been found that the amounts of urea and creatinine decreased as disease evoluted from CTR to LR/HR and DI (PC1, p<0.05), and the amount of glucose increased in the urine of LR/HR compared to CTR (PC3, p<0.05). The discriminating model showed better overall classification rate of 70%. These results could lead to diagnostic information of possible complications and a better disease prognosis.

  2. Correlating the amount of urea, creatinine, and glucose in urine from patients with diabetes mellitus and hypertension with the risk of developing renal lesions by means of Raman spectroscopy and principal component analysis.

    PubMed

    Bispo, Jeyse Aliana Martins; de Sousa Vieira, Elzo Everton; Silveira, Landulfo; Fernandes, Adriana Barrinha

    2013-08-01

    Patients with diabetes mellitus and hypertension (HT) diseases are predisposed to kidney diseases. The objective of this study was to identify potential biomarkers in the urine of diabetic and hypertensive patients through Raman spectroscopy in order to predict the evolution to complications and kidney failure. Urine samples were collected from control subjects (CTR) and patients with diabetes and HT with no complications (lower risk, LR), high degree of complications (higher risk, HR), and doing blood dialysis (DI). Urine samples were stored frozen (-20°C) before spectral analysis. Raman spectra were obtained using a dispersive spectrometer (830-nm, 300-mW power, and 20-s accumulation). Spectra were then submitted to principal component analysis (PCA) followed by discriminant analysis. The first PCA loading vectors revealed spectral features of urea, creatinine, and glucose. It has been found that the amounts of urea and creatinine decreased as disease evoluted from CTR to LR/HR and DI (PC1, p<0.05), and the amount of glucose increased in the urine of LR/HR compared to CTR (PC3, p<0.05). The discriminating model showed better overall classification rate of 70%. These results could lead to diagnostic information of possible complications and a better disease prognosis.

  3. Determination of urine ionic composition with potentiometric multisensor system.

    PubMed

    Yaroshenko, Irina; Kirsanov, Dmitry; Kartsova, Lyudmila; Sidorova, Alla; Borisova, Irina; Legin, Andrey

    2015-01-01

    The ionic composition of urine is a good indicator of patient's general condition and allows for diagnostics of certain medical problems such as e.g., urolithiasis. Due to environmental factors and malnutrition the number of registered urinary tract cases continuously increases. Most of the methods currently used for urine analysis are expensive, quite laborious and require skilled personnel. The present work deals with feasibility study of potentiometric multisensor system of 18 ion-selective and cross-sensitive sensors as an analytical tool for determination of urine ionic composition. In total 136 samples from patients of Urolithiasis Laboratory and healthy people were analyzed by the multisensor system as well as by capillary electrophoresis as a reference method. Various chemometric approaches were implemented to relate the data from electrochemical measurements with the reference data. Logistic regression (LR) was applied for classification of samples into healthy and unhealthy producing reasonable misclassification rates. Projection on Latent Structures (PLS) regression was applied for quantitative analysis of ionic composition from potentiometric data. Mean relative errors of simultaneous prediction of sodium, potassium, ammonium, calcium, magnesium, chloride, sulfate, phosphate, urate and creatinine from multisensor system response were in the range 3-13% for independent test sets. This shows a good promise for development of a fast and inexpensive alternative method for urine analysis. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Urine-Based Nested PCR for the Diagnosis of Mycobacterium tuberculosis: A Comparative Study Between HIV-Positive and HIV-Negative Patients.

    PubMed

    Jamshidi Makiani, Mahin; Davoodian, Parivash; Baghershiroodi, Mahnaz; Nejatizadeh, Abdol Azim; Fakkhar, Farideh; Zangeneh, Mehrangiz; Jahangiri, Nadia

    2016-08-01

    While tuberculosis (TB) can be diagnosed by microscopy and culture, the sensitivity of Ziehl-Neelsen staining is variable and culture results require 4 - 8 weeks to be determined. Polymerase chain reaction (PCR) and its modifications, including nested PCR, might be promising methods for the rapid diagnosis of TB. This study aimed to evaluate the performance of nested PCR on urine samples of human immunodeficiency virus (HIV)-positive and -negative patients with different manifestations of clinical TB. In a prospective study, three early-morning urine samples from 100 patients with pulmonary TB (PTB) or extrapulmonary TB (EPTB) were evaluated using a molecular target with insertion element IS6110, specific to the Mycobacterium tuberculosis genome, and nested PCR was performed. The results were analyzed with SPSS version 22. A total of 100 patients, including 74 (74%) with PTB and 26 (26%) with EPTB, were enrolled. Positive smears were seen in 38 patients (38%). Lymph nodes were the most commonly involved organ in 14 of the 26 (53.8%) EPTB patients (13.5%). Seven (23.1%) of the EPTB patients were HIV-positive. Urine PCR was positive in only 28 patients (28%). Seven HIV-positive patients with PTB showed positive urine PCR results. Moreover, PCR results were positive in only one of the seven HIV-positive subjects with EPTB. Positive PCR results were found in 20 of the 73 HIV-negative patients (27.4%) and in 8 of the 27 HIV-positive patients (29.6%). Therefore, there was no significant difference between the HIV-negative and HIV-positive patients for urine PCR (sensitivity 29.6%, specificity 72.6%; positive and negative predictive values 28% and 72%, respectively; P = 0.138). Nested PCR showed the same sensitivity in HIV-positive and HIV-negative patients. It can be applied as a rapid technique for the diagnosis of TB.

  5. Excretion profile of boldenone in urine of veal calves fed two different milk replacers.

    PubMed

    Draisci, R; Merlanti, R; Ferretti, G; Fantozzi, L; Ferranti, C; Capolongo, F; Segato, S; Montesissa, C

    2007-03-14

    The residue profiles of 17alpha-/17beta-boldenone conjugated (17alpha/beta-Bol) and ADD were investigated by liquid chromatography-tandem mass spectrometry (LC-MS/MS) in urine of male veal calves fed two commercial milk replacers, with different content of cholesterol and phytosterols. The urine samples were collected within 4 h after feeding and further from all the animals. Detectable amounts of 17alpha-Bol conjugated were measured in urine collected from all calves, but the concentrations of 17alpha-Bol were higher in urine from calves receiving the milk replacer with the greater amount of phytosterols. During the whole experiment, 17beta-Bol and ADD were never detected in urine samples collected.

  6. Mass spectrometric characterization of tamoxifene metabolites in human urine utilizing different scan parameters on liquid chromatography/tandem mass spectrometry.

    PubMed

    Mazzarino, Monica; de la Torre, Xavier; Di Santo, Roberto; Fiacco, Ilaria; Rosi, Federica; Botrè, Francesco

    2010-03-01

    Different liquid chromatographic/tandem mass spectrometric (LC/MS/MS) scanning techniques were considered for the characterization of tamoxifene metabolites in human urine for anti-doping purpose. Five different LC/MS/MS scanning methods based on precursor ion scan (precursor ion scan of m/z 166, 152 and 129) and neutral loss scan (neutral loss of 72 Da and 58 Da) in positive ion mode were assessed to recognize common ions or common losses of tamoxifene metabolites. The applicability of these methods was checked first by infusion and then by the injection of solution of a mixture of reference standards of four tamoxifene metabolites available in our laboratory. The data obtained by the analyses of the mixture of the reference standards showed that the five methods used exhibited satisfactory results for all tamoxifene metabolites considered at a concentration level of 100 ng/mL, whereas the analysis of blank urine samples spiked with the same tamoxifene metabolites at the same concentration showed that the neutral loss scan of 58 Da lacked sufficient specificity and sensitivity. The limit of detection in urine of the compounds studied was in the concentration range 10-100 ng/mL, depending on the compound structure and on the selected product ion. The suitability of these approaches was checked by the analysis of urine samples collected after the administration of a single dose of 20 mg of tamoxifene. Six metabolites were detected: 4-hydroxytamoxifene, 3,4-dihydroxytamoxifene, 3-hydroxy-4-methoxytamoxifene, N-demethyl-4-hydroxytamoxifene, tamoxifene-N-oxide and N-demethyl-3-hydroxy-4-methoxytamoxifene, which is in conformity to our previous work using a time-of-flight (TOF) mass spectrometer in full scan acquisition mode. Copyright (c) 2010 John Wiley & Sons, Ltd.

  7. Preparation of chitosan grafted graphite composite for sensitive detection of dopamine in biological samples.

    PubMed

    Palanisamy, Selvakumar; Thangavelu, Kokulnathan; Chen, Shen-Ming; Gnanaprakasam, P; Velusamy, Vijayalakshmi; Liu, Xiao-Heng

    2016-10-20

    The accurate detection of dopamine (DA) levels in biological samples such as human serum and urine are essential indicators in medical diagnostics. In this work, we describe the preparation of chitosan (CS) biopolymer grafted graphite (GR) composite for the sensitive and lower potential detection of DA in its sub micromolar levels. The composite modified electrode has been used for the detection of DA in biological samples such as human serum and urine. The GR-CS composite modified electrode shows an enhanced oxidation peak current response and low oxidation potential for the detection of DA than that of electrodes modified with bare, GR and CS discretely. Under optimum conditions, the fabricated GR-CS composite modified electrode shows the DPV response of DA in the linear response ranging from 0.03 to 20.06μM. The detection limit and sensitivity of the sensor were estimated as 0.0045μM and 6.06μA μM(-1)cm(-2), respectively. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Sample handling for mass spectrometric proteomic investigations of human urine.

    PubMed

    Petri, Anette Lykke; Høgdall, Claus; Christensen, Ib Jarle; Simonsen, Anja Hviid; T'jampens, Davy; Hellmann, Marja-Leena; Kjaer, Susanne Krüger; Fung, Eric T; Høgdall, Estrid

    2008-09-01

    Because of its non-invasive sample collection method, human urine is an attractive biological material both for discovering biomarkers and for use in future screening trials for different diseases. Before urine can be used for these applications, standardized protocols for sample handling that optimize protein stability are required. In this explorative study, we examine the influence of different urine collection methods, storage temperatures, storage times, and repetitive freeze-thaw procedures on the protein profiles obtained by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS). Prospectively collected urine samples from 11 women were collected as either morning or midday specimens. The effects of storage temperature, time to freezing, and freeze-thaw cycles were assessed by calculating the number, intensity, and reproducibility of peaks visualized by SELDI-TOF-MS. On the CM10 array, 122 peaks were detected and 28 peaks were found to be significantly different between urine types, storage temperature and time to freezing. On the IMAC-Cu array, 65 peaks were detected and 1 peak was found to be significantly different according to time to freezing. No significant differences were demonstrated for freeze-thaw cycles. Optimal handling and storage conditions are necessary in clinical urine proteomic investigations. Collection of urine with a single and consistently performed protocol is needed to reduce analytical bias. Collecting only one urine type, which is stored for a limited period at 4°C until freezing at -80°C prior to analysis will provide the most stable profiles. Copyright © 2008 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Evaluation of hematological and biochemical parameters of pesticide retailers following occupational exposure to a mixture of pesticides.

    PubMed

    Neghab, Masoud; Jalilian, Hamed; Taheri, Shekoufeh; Tatar, Mohsen; Haji Zadeh, Zeynab

    2018-06-01

    This study was undertaken to ascertain whether light occupational exposure to pesticides by retailers might be associated with any liver, kidney, nervous system dysfunction or hematological abnormalities. In this cross-sectional study, 70 male pesticide retailers (cases) and 64 male subjects, randomly selected from the constructions workers of city council contractors, as the referent group, were investigated. Urine and blood samples were taken from all subjects for urine analysis, hematological and biochemical parameters. Data analysis was conducted through SPSS v.19 using t-test and chi-square test. The results of urine analysis showed that the frequency of abnormal urine tests was significantly higher in cases than in referent individuals. Similarly, the results of CBC showed that the mean values of monocyte, hemoglobin, hematocrit, mean corpuscular volume, mean corpuscular hemoglobin and platelet distribution width were significantly lower, and mean corpuscular hemoglobin concentration and red blood cell distribution width were significantly higher in retailers. No significant differences were found for other parameters. These findings indicate that an association exists between exposure to pesticides by retailers and early subtle and sub-clinical changes in the urine tests and hematological parameters. Engineering measures are recommended to eliminate exposure to pesticides and to prevent its associated outcomes. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. Manganese in exhaled breath condensate: a new marker of exposure to welding fumes.

    PubMed

    Hulo, Sébastien; Chérot-Kornobis, Nathalie; Howsam, Mike; Crucq, Sébastien; de Broucker, Virginie; Sobaszek, Annie; Edme, Jean-Louis

    2014-04-07

    To evaluate manganese in exhaled breath condensate (Mn-EBC) as an indicator of exposure to fumes from metal inert gas welding process. We collected EBC and urine from 17 welders and 16 unexposed control subjects after 5 days exposure. Concentrations of manganese (Mn), nickel (Ni), iron (Fe) and chromium (Cr) were measured in EBC and urine samples and correlated with cumulative exposure indices for the working week (CIW) and for the total welding years (WY), based on duration of welding activity and atmospheric metal measurements. Concentrations of Mn and Ni in EBC were significantly higher among welders than controls whereas this difference was not significant for Mn in urine. Levels of Mn and Ni in EBC were not correlated with their respective levels in urine. The linear regressions found significant positive coefficients between Mn-EBC, Ni-EBC, Ni-U and Cr-U concentrations and the cumulative exposure indices. Taking into account tobacco use, statistical analysis showed the same trends except for the relationship between Mn-U and CIW. This pilot study showed that Mn-EBC, as well as Ni-EBC, can serve as reliable indices of occupational exposure to welding fumes and provide complimentary toxicokinetic information to that provided by urine analyses. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  11. Practical Bench Comparison of BBL CHROMagar Orientation and Standard Two-Plate Media for Urine Cultures

    PubMed Central

    D'Souza, Holly A.; Campbell, Mary; Baron, Ellen Jo

    2004-01-01

    A total of 1,023 urine samples sent for routine culture were plated onto sheep blood and MacConkey agars and a BBL CHROMagar Orientation (CO; Becton Dickinson, Cockeysville, Md.) plate, and the results were compared. Of these, 250 urine samples (24%) grew >10,000 CFU of one or two putative pathogens/ml and 773 showed no growth (NG), mixed growth of <10,000 CFU/ml, or three or more strains (mixed). The CO and conventional medium results agreed completely for 595 cultures with NG or <10,000 CFU/ml. An additional 178 urine samples yielded clinically insignificant differences. Both medium sets essentially agreed on quantities and identification for 400 single-pathogen cultures and 9 mixed cultures. With the caveat that CO cannot differentiate Klebsiella, Enterobacter, and Serratia spp., enteric pathogens were identified only by morphology and color on CO. Direct visual differentiation of group B streptococci from lactobacilli is not possible, but lactobacillus cells always exhibited easily recognizable morphology on Gram stain. Of 108 paired organism susceptibility results encompassing 2,268 drug-pathogen combinations, there were 3% errors and only 1% very major errors. Use of CO allowed a >50% reduction in inoculation time and a >20% reduction in work-up time. For our laboratory, with 50% “no growth” and ca. 25% significant results (50% Escherichia coli), CO allowed time and workup cost savings for a majority of cultures. A cost analysis (time and supplies for our laboratory) showed that if CO is used alone, the break-even level for CO pricing is $1.78; if CO and blood agar are both used, the break-even pricing for CO is $1.53. PMID:14715732

  12. NHEXAS PHASE I REGION 5 STUDY--STANDARD OPERATING PROCEDURE--HUMAN BIOLOGICAL MARKERS:BLOOD AND URINE SAMPLE COLLECTION AND ANALYSES (EOHSI-AP-209-040)

    EPA Science Inventory

    This procedure describes the process for collecting and analyzing blood and urine samples. The presence of chemical contaminants in biological specimens such as blood, urine, and hair represent a measure of the internal dose or body burden for a given individual derived from the ...

  13. Depleted uranium dust from fired munitions: physical, chemical and biological properties.

    PubMed

    Mitchel, R E J; Sunder, S

    2004-07-01

    This paper reports physical, chemical and biological analyses of samples of dust resulting from munitions containing depleted uranium (DU) that had been live-fired and had impacted an armored target. Mass spectroscopic analysis indicated that the average atom% of U was 0.198 +/- 0.10, consistent with depleted uranium. Other major elements present were iron, aluminum, and silicon. About 47% of the total mass was particles with diameters <300 microm, of which about 14% was <10 microm. X-ray diffraction analysis indicated that the uranium was present in the sample as uranium oxides-mainly U3O7 (47%), U3O8 (44%) and UO2 (9%). Depleted uranium dust, instilled into the lungs or implanted into the muscle of rats, contained a rapidly soluble uranium component and a more slowly soluble uranium component. The fraction that underwent dissolution in 7 d declined exponentially with increasing initial burden. At the lower lung burdens tested (<15 microg DU dust/lung) about 14% of the uranium appeared in urine within 7 d. At the higher lung burdens tested (~80-200 microg DU dust/lung) about 5% of the DU appeared in urine within 7 d. In both cases about 50% of that total appeared in urine within the first day. DU implanted in muscle similarly showed that about half of the total excreted within 7 d appeared in the first day. At the lower muscle burdens tested (<15 microg DU dust/injection site) about 9% was solubilized within 7 d. At muscle burdens >35 microg DU dust/injection site about 2% appeared in urine within 7 d. Natural uranium (NU) ore dust was instilled into rat lungs for comparison. The fraction dissolving in lung showed a pattern of exponential decline with increasing initial burden similar to DU. However, the decline was less steep, with about 14% appearing in urine for lung burdens up to about 200 microg NU dust/lung and 5% at lung burdens >1,100 microg NU dust/lung. NU also showed both a fast and a more slowly dissolving component. At the higher lung burdens of both DU and NU that showed lowered urine excretion rates, histological evidence of kidney damage was seen. Kidney damage was not seen with the muscle burdens tested. DU dust produced kidney damage at lower lung burdens and lower urine uranium levels than NU dust, suggesting that other toxic metals in DU dust may contribute to the damage.

  14. Distribution, variability, and predictors of urinary bisphenol A levels in 50 North Carolina adults over a six-week monitoring period.

    PubMed

    Morgan, Marsha K; Nash, Maliha; Barr, Dana Boyd; Starr, James M; Scott Clifton, M; Sobus, Jon R

    2018-03-01

    Bisphenol A (BPA) is commonly manufactured to make polycarbonate plastics and epoxy resins for use in consumer products and packaged goods. BPA has been found in several different types of environmental media (e.g., food, dust, and air). Many cross-sectional studies have frequently detected BPA concentrations in adult urine samples. However, limited data are available on the temporal variability and important predictors of urinary BPA concentrations in adults. In this work, the major objectives were to: 1) quantify BPA levels in duplicate-diet solid food, drinking water, hard floor surface wipe, and urine samples (first-morning void [FMV], bedtime, and 24-h) collected from adults over a six-week monitoring period; 2) determine the temporal variability of urinary BPA levels using concentration, specific gravity (SG) adjusted, creatinine (CR) adjusted, and excretion rate values, and; 3) examine associations between available study factors and urinary BPA concentrations. In 2009-2011, a convenience sample of 50 adults was recruited from residential settings in North Carolina. The participants completed diaries and collected samples during weeks 1, 2, and/or 6 of a six-week monitoring period. BPA was detected in 38%, 4%, and 99% of the solid food (n=775), drinking water (n=50), and surface wipe samples (n=138), respectively. Total BPA (free plus conjugated) was detected in 98% of the 2477 urine samples. Median urinary BPA levels were 2.07ng/mL, 2.20ng/mL-SG, 2.29ng/mg, and 2.31ng/min for concentration, SG-adjusted, CR-adjusted, and excretion rate values, respectively. The intraclass correlation coefficient (ICC) estimates for BPA showed poor reproducibility (≤0.35) for all urine sample types and methods over a day, week, and six weeks. CR-adjusted bedtime voids collected over six-weeks required the fewest, realistic number of samples (n=11) to obtain a reliable biomarker estimate (ICC=0.80). Results of linear mixed-effects models showed that sex, race, season, and CR-level were all significant predictors (p<0.05) of the adults' urinary BPA concentrations. BPA levels in the solid food and surface wipe samples did not contribute significantly to the participants' urinary BPA concentrations. However, a significant positive relationship was observed between solid food intake and urine-based estimates of BPA dose, when aggregated over 24-h periods. Ingestion of BPA via solid food explained only about 20% of the total dose (at the median of the dose distribution), suggesting that these adults were likely exposed to other major unknown (non-dietary) sources of BPA in their everyday environments. Published by Elsevier Ltd.

  15. Comparison of sodium, potassium, calcium, magnesium, zinc, copper and iron concentrations of elements in 24-h urine and spot urine in hypertensive patients with healthy renal function.

    PubMed

    Zhang, Tianjing; Chang, Xiaoyu; Liu, Wanlu; Li, Xiaoxia; Wang, Faxuan; Huang, Liping; Liao, Sha; Liu, Xiuying; Zhang, Yuhong; Zhao, Yi

    2017-12-01

    Sodium, potassium, calcium, magnesium, zinc, copper and iron are associated with the sequela of hypertension. The most reliable method for testing those elements is by collecting 24-h urine samples. However, this is cumbersome and collection of spot urine is more convenient in some circumstance. The aim of this study was to compare the concentrations of different elements in 24-h urine and spot urine. Data was collected from a sub-study of China Salt Substitute and Stroke Study. 240 participants were recruited randomly from 12 villages in two counties in Ningxia, China. Both spot and 24-h urine specimens were collected from each patient. Routine urine test was conducted, and concentration of elements was measured using microwave digestion and Inductively Coupled Plasma-Optical Emission Spectrometry. Partial correlation analysis and Spearman correlation analysis were used to investigate the concentration of different elements and the relationship between 24- h urine and spot urine. A partial correlation in sodium, potassium, calcium, magnesium and iron was found between paired 24-h urine and spot urine samples except copper and zinc: 0.430, 0.426, 0.550, 0.221 and 0.191 respectively. Spot urine can replace 24-h urine for estimating some of the elements in hypertensive patients with normal renal function. Copyright © 2017 Elsevier GmbH. All rights reserved.

  16. Evaluation of equine urine reactivity towards phase II metabolites of 17-hydroxy steroids by liquid chromatography/tandem mass spectrometry.

    PubMed

    Fidani, M; Gamberini, M C; Pasello, E; Palazzoli, F; De Iuliis, P; Montana, M; Arioli, F

    2009-01-01

    Proper storage conditions of biological samples are fundamental to avoid microbiological contamination that can cause chemical modifications of the target analytes. A simple liquid chromatography/tandem mass spectrometry (LC/MS/MS) method through direct injection of diluted samples, without prior extraction, was used to evaluate the stability of phase II metabolites of boldenone and testosterone (glucuronides and sulphates) in intentionally poorly stored equine urine samples. We also considered the stability of some deuterated conjugated steroids generally used as internal standards, such as deuterated testosterone and epitestosterone glucuronides, and deuterated boldenone and testosterone sulphates. The urines were kept for 1 day at room temperature, to mimic poor storage conditions, then spiked with the above steroids and kept at different temperatures (-18 degrees C, 4 degrees C, room temperature). It has been possible to confirm the instability of glucuronide compounds when added to poorly stored equine urine samples. In particular, both 17beta- and 17alpha-glucuronide steroids were exposed to hydrolysis leading to non-conjugated steroids. Only 17beta-hydroxy steroids were exposed to oxidation to their keto derivatives whereas the 17alpha-hydroxy steroids were highly stable. The sulphate compounds were completely stable. The deuterated compounds underwent the same behaviour as the unlabelled compounds. The transformations were observed in urine samples kept at room temperature and at a temperature of 4 degrees C (at a slower rate). No modifications were observed in frozen urine samples. In the light of the latter results, the immediate freezing at -18 degrees C of the collected samples and their instant analysis after thawing is the proposed procedure for preventing the transformations that occur in urine, usually due to microbiological contamination. (c) 2008 John Wiley & Sons, Ltd.

  17. [An investigation of lanthanum and other metals levels in blood, urine and hair among residents in the rare earth mining area of a city in China].

    PubMed

    Bao, T M; Tian, Y; Wang, L X; Wu, T; Lu, L N; Ma, H Y; Wang, L

    2018-02-20

    Objective: To investigate the levels of lanthanum, cerium, praseodymium, and neodymium in the blood, urine, and hair samples from residents in the rare earth mining area of a city in China, and to provide a scientific basis for the control of rare earth pollution and the protection of population health. Methods: A total of 147 residents who had lived in the rare earth mining area of a city for a long time were selected as the exposure group, and 108 residents in Guyang County of this city who lived 91 km away from the rare earth mining area were selected as the control group. Blood, urine, and hair samples were collected from the residents in both groups. Inductively coupled plasma mass spectrometry was used to determine the content of lanthanum, cerium, praseodymium, and neodymium in blood, urine, and hair samples. Results: In the exposure group, the median levels of lanthanum, cerium, praseodymium, and neodymium were 0.854, 1.724, 0.132, and 0.839 μg/L, respectively, in blood samples, 0.420, 0.920, 0.055, and 0.337 μg/L, respectively, in urine samples, and 0.052, 0.106, 0.012, and 0.045 μg/g, respectively, in hair samples. The exposure group had significantly higher levels of the four rare earth elements in blood, urine, and hair samples than the control group ( P <0.01) . Conclusion: The residents in the rare earth mining area of this city have higher content of lanthanum, cerium, praseodymium, and neodymium in blood, urine, and hair than those in the non-mining area; the content of cerium is highest, followed by lanthanum, neodymium, and praseodymium.

  18. Simultaneous and confirmative detection of multi-residues of β₂-agonists and β-blockers in urine using LC-MS/MS/MS coupled with β-receptor molecular imprinted polymer SPE clean-up.

    PubMed

    Fan, S; Zou, J H; Miao, H; Zhao, Y F; Chen, H J; Zhao, R; Wu, Y N

    2013-01-01

    A liquid chromatography-linear ion-trap spectrometry (LC-MS³) method using β-receptor molecular-imprinted polymer (MIP) solid-phase extraction (SPE) as clean-up was developed to determine simultaneously and confirmatively residues of 25 β₂-agonists and 21 β-blockers in urine samples. Urine samples were subjected to enzymatic hydrolysis by β-glucoronidase/arylsulphatase, and then extracted with perchloric acid. Sample clean-up was performed using β-receptor MIP SPE. A Supelco Ascentis® express Rp-Amide column was used to separate the analytes, and MS³ detection used an electrospray ionisation source in positive-ion mode. Recovery studies were carried out using blank urine samples fortified with the 46 analytes at the levels of 0.5, 1.0 and 2.0 μg l⁻¹. Recoveries were obtained ranging from 60.1% to 109.9% with relative standard deviations (RSDs, n = 7) from 0.5% to 19.4%. The limits of detection (LODs) and limits of quantitation (LOQs) of the 46 analytes in urine were 0.02-0.18 and 0.05-0.60 μg l⁻¹, respectively. As a result of the selective clean-up by MIP SPE and MS³ detection of the target drugs, the sensitivity and accuracy of the present method was high enough for monitoring β₂-agonist and β-blocker residues in urine samples. Satisfactory results were obtained in the process of the determination of positive urine samples.

  19. Impact of urine preservation methods and duration of storage on measured levels of environmental contaminants.

    PubMed

    Hoppin, Jane A; Ulmer, Ross; Calafat, Antonia M; Barr, Dana B; Baker, Susan V; Meltzer, Helle M; Rønningen, Kjersti S

    2006-01-01

    Collection of urine samples in human studies involves choices regarding shipping, sample preservation, and storage that may ultimately influence future analysis. As more studies collect and archive urine samples to evaluate environmental exposures in the future, we were interested in assessing the impact of urine preservative, storage temperature, and time since collection on nonpersistent contaminants in urine samples. In spiked urine samples stored in three types of urine vacutainers (no preservative, boric acid, and chlorhexidine), we measured five groups of contaminants to assess the levels of these analytes at five time points (0, 24, 48, and 72 h, and 1 week) and at two temperatures (room temperature and 4 degrees C). The target chemicals were bisphenol A (BPA), metabolites of organophosphate (OP), carbamate, and pyrethroid insecticides, chlorinated phenols, and phthalate monoesters, and were measured using five different mass spectrometry-based methods. Three samples were analyzed at each time point, with the exception of BPA. Repeated measures analysis of variance was used to evaluate effects of storage time, temperature, and preservative. Stability was summarized with percent change in mean concentration from time 0. In general, most analytes were stable under all conditions with changes in mean concentration over time, temperature, and preservative being generally less than 20%, with the exception of the OP metabolites in the presence of boric acid. The effect of storage temperature was less important than time since collection. The precision of the laboratory measurements was high allowing us to observe small differences, which may not be important when categorizing individuals into broader exposure groups.

  20. Feasibility of collecting 24-h urine to monitor sodium intake in the National Health and Nutrition Examination Survey123

    PubMed Central

    Terry, Ana L; Cogswell, Mary E; Wang, Chia-Yih; Chen, Te-Ching; Loria, Catherine M; Wright, Jacqueline D; Zhang, Xinli; Lacher, David A; Merritt, Robert K; Bowman, Barbara A

    2016-01-01

    Background: Twenty-four–hour urine sodium excretion is recommended for monitoring population sodium intake. Because of concerns about participation and completion, sodium excretion has not been collected previously in US nationally representative surveys. Objective: We assessed the feasibility of implementing 24-h urine collections as part of a nationally representative survey. Design: We selected a random half sample of nonpregnant US adults aged 20–69 y in 3 geographic locations of the 2013 NHANES. Participants received explicit instructions, started and ended the urine collection in a urine study mobile examination center, and answered questions about their collection. Among those with a complete 24-h urine collection, a random one-half were asked to collect a second 24-h urine sample. Sodium, potassium, chloride, and creatinine excretion were analyzed. Results: The final NHANES examination response rate for adults aged 20–69 y in these 3 study locations was 71%. Of those examined (n = 476), 282 (59%) were randomly selected to participate in the 24-h urine collection. Of these, 212 persons [75% of those selected for 24-h urine collection; 53% (equal to 71% × 75% of those selected for the NHANES)] collected a complete initial 24-h specimen and 92 persons (85% of 108 selected) collected a second complete 24-h urine sample. More men than women completed an initial collection (P = 0.04); otherwise, completion did not vary by sociodemographic characteristics, body mass index, education, or employment status for either collection. Mean 24-h urine volume and sodium excretion were 1964 ± 1228 mL and 3657 ± 2003 mg, respectively, for the first 24-h urine sample, and 2048 ± 1288 mL and 3773 ± 1891 mg, respectively, for the second collection. Conclusion: Given the 53% final component response rate and 75% completion rate, 24-h urine collections were deemed feasible and implemented in the NHANES 2014 on a subsample of adults aged 20–69 y to assess population sodium intake. This study was registered at clinicaltrials.gov as NCT02723682. PMID:27413136

  1. Employment-based Reinforcement of Adherence to Oral Naltrexone in Unemployed Injection Drug Users: 12-month Outcomes

    PubMed Central

    Dunn, Kelly; DeFulio, Anthony; Everly, Jeffrey J.; Donlin, Wendy D.; Aklin, Will M.; Nuzzo, Paul A.; Leoutsakos, Jeannie-Marie S.; Umbricht, Annie; Fingerhood, Michael; Bigelow, George E.; Silverman, Kenneth

    2015-01-01

    Oral naltrexone could be a promising relapse prevention pharmacotherapy for recently detoxified opioid-dependent patients, however interventions are often needed to promote adherence with this treatment approach. We recently conducted a study to evaluate a 26-week employment-based reinforcement intervention of oral naltrexone in unemployed injection drug users (Dunn et al., 2013). Participants were randomly assigned into a Contingency (n=35) group required to ingest naltrexone under staff observation to gain entry into a therapeutic workplace, or a Prescription (n=32) group given a take-home supply of oral naltrexone and access to the workplace without observed ingestion. Monthly urine samples were collected and analyzed for evidence for naltrexone adherence, opioid use, and cocaine use. As previously reported, Contingency participants provided significantly more naltrexone-positive urine samples than Prescription participants during the 26-week intervention period. The goal of this current study is to report the 12-month outcomes, which occurred 6 months after the intervention ended. Results at the 12-month visit showed no between-group differences in naltrexone-positive, opioid-negative, or cocaine-negative urine samples, and no participant self-reported using naltrexone at the follow-up visit. These results show that even after a period of successfully reinforced oral naltrexone adherence longer-term naltrexone use is unlikely to be maintained after reinforcement contingencies are discontinued. PMID:25134047

  2. A statistical analysis of the effects of urease pre-treatment on the measurement of the urinary metabolome by gas chromatography–mass spectrometry

    DOE PAGES

    Webb-Robertson, Bobbie-Jo; Kim, Young -Mo; Zink, Erika M.; ...

    2014-02-27

    Urease pre-treatment of urine has been utilized since the early 1960s to remove high levels of urea from samples prior to further processing and analysis by gas chromatography-mass spectrometry (GC-MS). Aside from the obvious depletion or elimination of urea, the effect, if any, of urease pre-treatment on the urinary metabolome has not been studied in detail. Here, we report the results of three separate but related experiments that were designed to assess possible indirect effects of urease pre-treatment on the urinary metabolome as measured by GC-MS. In total, 235 GC-MS analyses were performed and over 106 identified and 200 unidentifiedmore » metabolites were quantified across the three experiments. The results showed that data from urease pre-treated samples 1) had the same or lower coefficients of variance among reproducibly detected metabolites, 2) more accurately reflected quantitative differences and the expected ratios among different urine volumes, and 3) increased the number of metabolite identifications. Altogether, we observed no negative consequences of urease pre-treatment. In contrast, urease pretreatment enhanced the ability to distinguish between volume-based and biological sample types compared to no treatment. Taken together, these results show that urease pretreatment of urine offers multiple beneficial effects that outweigh any artifacts that may be introduced to the data in urinary metabolomics analyses.« less

  3. A Statistical Analysis of the Effects of Urease Pre-treatment on the Measurement of the Urinary Metabolome by Gas Chromatography-Mass Spectrometry

    PubMed Central

    Webb-Robertson, Bobbie-Jo; Kim, Young-Mo; Zink, Erika M.; Hallaian, Katherine A.; Zhang, Qibin; Madupu, Ramana; Waters, Katrina M.; Metz, Thomas O.

    2014-01-01

    Urease pre-treatment of urine has been utilized since the early 1960s to remove high levels of urea from samples prior to further processing and analysis by gas chromatography-mass spectrometry (GC-MS). Aside from the obvious depletion or elimination of urea, the effect, if any, of urease pre-treatment on the urinary metabolome has not been studied in detail. Here, we report the results of three separate but related experiments that were designed to assess possible indirect effects of urease pre-treatment on the urinary metabolome as measured by GC-MS. In total, 235 GC-MS analyses were performed and over 106 identified and 200 unidentified metabolites were quantified across the three experiments. The results showed that data from urease pre-treated samples 1) had the same or lower coefficients of variance among reproducibly detected metabolites, 2) more accurately reflected quantitative differences and the expected ratios among different urine volumes, and 3) increased the number of metabolite identifications. Overall, we observed no negative consequences of urease pre-treatment. In contrast, urease pretreatment enhanced the ability to distinguish between volume-based and biological sample types compared to no treatment. Taken together, these results show that urease pretreatment of urine offers multiple beneficial effects that outweigh any artifacts that may be introduced to the data in urinary metabolomics analyses. PMID:25254001

  4. Dietary sodium adherence is poor in chronic heart failure patients.

    PubMed

    Basuray, Anupam; Dolansky, Mary; Josephson, Richard; Sattar, Abdus; Grady, Ellen M; Vehovec, Anton; Gunstad, John; Redle, Joseph; Fang, James; Hughes, Joel W

    2015-04-01

    We sought to determine the rates and predictors of dietary sodium restriction and to evaluate the reliability of 24-hour urine collection as a tool to estimate dietary sodium intake in heart failure (HF) patients. We evaluated the 24-hour urinary sodium excretion of 305 outpatients with HF and reduced ejection fraction who were educated on following a <2 g sodium diet. The mean sodium excretion according to a single sample from each participant was 3.15 ± 1.58 g, and 23% were adherent to the <2 g recommendation. One hundred sixty-eight participants provided 2 samples with urinary creatinine excretion within normative range. Averaging both resulted in a mean sodium excretion of 3.21 ± 1.20 g and lower adherence rates to the <2-gram diet: 14% versus 23% (P = .019). Multivariate logistic regression showed only male sex and higher body mass index (BMI) to be associated with nonadherence (male: odds ratio [OR] 2.20, 95% confidence interval [CI] 1.25-3.88; 1 unit BMI: OR 1.05, 95% CI 1.01-1.10). Bland-Altman plots of urinary sodium and creatinine showed poor reproducibility between samples. In this chronic HF population, sodium consumption probably exceeds recommended amounts, particularly in men and those with higher BMI. Urine analyses were not highly reproducible, suggesting variation in both diet and urine collection. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. A urine midmolecule osteocalcin assay shows higher discriminatory power than a serum midmolecule osteocalcin assay during short-term alendronate treatment of osteoporotic patients.

    PubMed

    Srivastava, A K; Mohan, S; Singer, F R; Baylink, D J

    2002-07-01

    We isolated and characterized a peptide fragment corresponding to amino acid sequence 14-28 of human osteocalcin in urine from Paget's disease, and developed a polyclonal antibody reactive to this peptide in urine. We used this antibody to measure urinary fragments of osteocalcin and compared to efficacy of the urinary osteocalcin assay with a serum osteocalcin (sOC) assay (ELISA-Osteo, Cis-Bio International) to monitor the short-term changes in bone turnover in response to alendronate treatment. The synthetic peptide-based urinary osteocalcin (uOC) radioimmunoassay (RIA) showed an analytical sensitivity of 6.25 ng/mL, standard curve range of 3.12-400 ng/mL, and mean intra- (n = 20) and interassay (n = 30) coefficient of variation (CV) of <15%. Urine osteocalcin concentrations in postmenopausal osteoporotic patients were approximately 90% higher than in normal premenopausal controls. Series of 24 h urine and matched serum samples were collected at baseline, 30 days, and 90 days after treatment of postmenopausal osteoporotic patients with daily dose of 10 mg alendronate. We measured urinary osteocalcin (uOc) levels and urinary N-telopeptide (uNTx, Ostex) in urine samples and serum N-telopeptide (sNTx), C-telopeptide (sCTx, Osteometer), serum osteocalcin (sOC) as well as bone-specific alkaline phosphatase (sALP) (Alkphose-B, Metra Biosystems) in serum samples. The percent change data obtained between baseline and 30 days (n = 18) posttreatment suggested a rapid decline in uOC concentration (-27%, p < 0.01) in response to alendronate treatment, as compared with a marginal and nonsignificant decrease in sOC (-7.2%, p = 0.417) or sALP (-3.4%, p = 0.689), two specific markers of bone formation. As expected, due to the coupling of bone formation and bone resorption, the concentration of all markers showed a 30%-45% decline compared with baseline values after 90 days (n = 16) of treatment. Correlation of markers after a 30 day treatment with alendronate revealed a higher correlation (r = 0.61, p < 0.01) between uOC and uNTx, as compared with sOC (r = 0.03, p = 0.447) or sALP (r = -0.14, p = 0.295) with uNTx. Similarly, correlation coefficients with r values between 0.48 and 0.55 (p < 0.05) were observed between uOC, sNTx, and sCTx, whereas no significant correlation was observed between sOC and sNTx or sCTx. These results provide indirect evidence that fragments measured by the urine assay probably originated from bone resorption, and suggest that the uOC assay could be used to assess short-term changes in bone metabolism with regard to osteocalcin.

  6. Artificial Urine for Teaching Urinalysis Concepts and Diagnosis of Urinary Tract Infection in the Medical Microbiology Laboratory.

    PubMed

    Khan, Latifa B; Read, Hannah M; Ritchie, Stephen R; Proft, Thomas

    2017-01-01

    Dipstick urinalysis is an informative, quick, cost-effective and non-invasive diagnostic tool that is useful in clinical practice for the diagnosis of urinary tract infections (UTIs), kidney diseases, and diabetes. We used dipstick urinalysis as a hands-on microbiology laboratory exercise to reinforce student learning about UTIs with a particular focus on cystitis, which is a common bacterial infection. To avoid exposure to potentially contaminated human urine samples, we prepared artificial urine using easily acquired and affordable ingredients, which allowed less-experienced students to perform urinalysis without the risk of exposure to pathogenic organisms and ensured reliable availability of the urine samples. This practical class taught medical students how to use urinalysis data in conjunction with medical history to diagnose diseases from urine samples and to determine a treatment plan for clinical scenarios.

  7. Isolation of infectious Zika virus from a urine sample cultured in SIRC cells from a patient suspected of having rubella virus.

    PubMed

    Oliveira, Maria Isabel de; Namiyama, Gislene Mitsue; Cabral, Gabriela Bastos; Ferreira, João Leandro; Taniwaki, Noemi; Afonso, Ana Maria Sardinha; Lima, Isabella Rillo; Brigido, Luís Fernando Macedo de

    2018-01-01

    A great variety of viruses which cause exanthema share other clinical manifestations, making the etiologic identification a very difficult task, relying exclusively on the clinical examination. Rubella virus (RV) infection during the early stages of pregnancy can lead to serious birth defects, known as congenital rubella syndrome (CRS). In the present report, we described the presence of Zika virus (ZIKV) particles in urine samples and also ZIKV isolation in SIRC cells from the urine of a patient in acute phase of suspected rubella disease. The 50-year-old unvaccinated woman living in Sao Paulo, Brazil, was admitted to the emergency room with fever, headache, rash, arthralgia and prostration. Urine samples were collected for virus isolation and RT-qPCR. SIRC and Vero cells were inoculated with urine samples during 7 days. RT-qPCR was performed using measles virus (MV) and RV primers and both were found to be negative. After this result, RT-qPCR was performed for parvovirus B19, herpes virus 6 and ZIKV. The urine sample and the isolate were positive by Real Time PCR for ZIKV and negative for all other viruses tested. The sequences isolated are from the Asiatic lineage.

  8. [The role of telomerase activity in non-invasive diagnostics of bladder cancer].

    PubMed

    Glybochko, P V; Alyaev, J G; Potoldykova, N V; Polyakovsky, K A; Vinarov, A Z; Glukhov, A I; Gordeev, S A

    2016-08-01

    To evaluate the potentials of determining the telomerase activity (TA) in the cellular material of the urine for noninvasive diagnosis of bladder cancer (BC). Evaluation of TA was performed in the urine of 48 patients with bladder cancer (study group) before and after transurethral resection of the bladder wall (n=38), an open resection of the bladder (n=4), and cystectomy (n=6). TA was also evaluated in 48 tumor tissue samples obtained from these patients during removal of the bladder tumor. Each sample of the tumor tissue was separated into two parts, one of which was subjected to histological examination, and the latter was used to determine the telomerase activity. In all cases, the diagnosis of bladder cancer was confirmed morphologically. Determination of TA in the samples was performed by the modified TRAP-method (telomerase repeat amplification protocol), RT-PCR, PCR, and electrophoresis. As a control, cell material of the urine and tissue in 12 patients with chronic cystitis was investigated. TA before surgery was found in 45 (93.75%) of 48 samples of cellular material of the urine from patients with suspected bladder cancer. BC was histologically verified in all patients in this group. In the postoperative period, TA was not observed in the 48 samples of cellular material of the urine from patients with BC. In the control group of patients with histologically verified cystitis, weak TA was determined only in one sample of cellular material of the urine. The analysis indicates statistically significant predominance of patients with bladder cancer in case of TA in the urine (P=0.001). TA was detected in all samples of tumor tissue. We also analyzed the dependence of TA levels in urine and tissue on the degree of BC differentiation. In patients with highly differentiated BC, mean AT in the cellular materials of the urine was 0,61% (n=15), in patients with moderately differentiated BC - 0.95% (n=23), in patients with low-grade bladder cancer - 1.33% (n=10); in other words, increase in the TA levels with decreasing the degree of differentiation was observed. This finding can be used in the prognosis of the course of disease based on determining the TA level in these patients. Preliminary data indicate the possibility of use of determining the TA in cellular material of the urine for the diagnosis and monitoring of bladder cancer recurrence.

  9. [Effect of the chelator Zn-DTPA on the excretion of lead in lead intoxication mice detected with ICP-MS].

    PubMed

    Li, Chen; Lu, Kai-zhi; Zhou, Qi; Wang, Qiong; Zeng, Yu-liang; Yin, Hong-jun; He, Xuan-hui; Tian, Ying; Dong, Jun-Xing

    2014-11-01

    To study the lead excretion effect of the chelator Zn-DTPA on the lead intoxication mice, inductively coupled plasma mass spectrometry (ICP-MS) was applied to detect the lead content of biological samples. The acute lead intoxication mice model was established by injecting lead acetate intraperitoneally with the dose of 1 mg. Zn-DTPA was administered intraperitoneally to mice once daily for five consecutive days 4 h after intoxication. Control group, model group, combination of Zn-DTPA and Ca-DTPA group were evaluated at the same time. The urine was collected every day. The mice were sacrificed in batches in the 2rd, 4th, 6th day. Biological samples including urine, whole blood, femur and brain were prepared and nitrated. Lead concentration was detected by ICP-MS. The result showed that Zn-DTPA could increase lead content in urine markedly and reduce lead content in blood, femur and brain.

  10. [Clinical significance of monitoring BK polyomavirus in patients after hematopoietic stem cell transplantation].

    PubMed

    Yin, Chang-Xin; Jiang, Qian-Li; He, Han; Yu, Guo-Pan; Xu, Yue; Meng, Fan-Yi; Yang, Mo

    2012-02-01

    This study was aimed to establish a method for rapid detecting BK polyomavirus (BKV) and to investigate the feasibility and value used in leukemia patients undergoing hematopoietic stem cell transplantation. Primers were designed according to BKV gene sequence; the quantitative standards for BKV and a real-time fluorescent quantitative PCR for BKV were established. The BKV level in urine samples from 36 patients after hematopoietic stem cell transplantation were detected by established method. The results showed that the standard of reconstructed plasmid and real time fluorescent quantitative PCR method were successfully established, its good specificity, sensitivity and stability were confirmed by experiments. BKV was found in 55.56% of urine samples, and the BKV load in urine was 2.46 × 10(4) - 7.8 × 10(9) copy/ml. It is concluded that the establishment of real-time fluorescent quantitative PCR for BKV detection provides a method for early diagnosis of the patients with hemorrhagic cystitis after hematopoietic stem cell transplantation.

  11. Urine Collected From Diapers Can Be Used for 2-Dimensional Polyacrylamide Gel Electrophoresis (2D-PAGE) in Infants and Young Children

    PubMed Central

    Kennedy, Mary Jayne; Griffin, Angela; Su, Ruifeng; Merchant, Michael; Klein, Jon

    2011-01-01

    Urinary proteomic profiling has potential to identify candidate biomarkers of renal injury in infants provided an adequate urine sample can be obtained. Although diapers are used to obtain urine for clinical evaluation, their use for proteomic analysis has not been investigated. We therefore performed feasibility studies on the use of diaper-extracted urine for 2-dimensional polyacrylamide gel electrophoresis (2D-PAGE). Pediatric waste urine (2–20 mL) was applied to gel-containing, non-gel and cotton-gauze diapers and then mechanically expressed. Urine volume and total protein were measured pre- and post-extraction. Proteins were separated via 2D-PAGE following application of urine (20–40 mL) to each matrix. 2D-PAGE was also performed on clinical specimens collected using each diaper type. Differences in the adsorption and retention of urine volume and protein were noted between matrices. Non-gel and cotton-gauze diapers provided the best protein/volume recovery and the lowest interference with the Bradford assay. 2D-PAGE was also successfully completed using urine samples from both cotton fiber matrices. Conversely, samples from low-gel diapers demonstrated poor protein separation and reproducibility. Diapers containing cotton-fiber matrices appear adequate for 2D-PAGE. Qualitative and quantitative analyses of resolved proteins using replicate, high resolution gels will be required, however, before diaper-extracted urine can be applied in proteomic profiling. PMID:21137001

  12. Comparison of a digital and an optical analogue hand-held refractometer for the measurement of canine urine specific gravity.

    PubMed

    Paris, J K; Bennett, A D; Dodkin, S J; Gunn-Moore, D A

    2012-05-05

    Urine specific gravity (USG) is used clinically as a measure of urine concentration, and is routinely assessed by refractometry. A comparison between optical analogue and digital refractometers for evaluation of canine urine has not been reported. The aim of this study was to compare a digital and an optical analogue hand-held refractometer for the measurement of canine USG, and to assess correlation with urine osmolality. Prospective study. Free-catch urine samples were collected from 285 hospitalised adult dogs, and paired USG readings were obtained with a digital and an optical analogue refractometer. In 50 dogs, urine osmolality was also measured using a freezing point depression osmometer. There was a small but statistically significant difference between the two refractometers (P<0.001), with the optical analogue refractometer reading higher than the digital refractometer (mean difference 0.0006, sd 0.0012). Paired refractometer measurements varied by <0.002 in 91.5 per cent of cases. The optical analogue and digital refractometer readings showed excellent correlation with osmolality (r=0.980 and r=0.977, respectively, P<0.001 in both cases). Despite statistical significance, the difference between the two refractometers is unlikely to be clinically significant. Both instruments provide an accurate assessment of USG in dogs.

  13. Determination of steroid sex hormones in water and urine matrices by stir bar sorptive extraction and liquid chromatography with diode array detection.

    PubMed

    Almeida, C; Nogueira, J M F

    2006-06-16

    In this study, stir bar sorptive extraction and liquid desorption followed by high performance liquid chromatography with diode array detection (SBSE-LD-HPLC/DAD) were combined for the simultaneous determination of nine steroid sex hormones (estrone, 17alpha-estradiol, 17beta-estradiol, 17alpha-ethynylestradiol, diethylstilbestrol, mestranol, progesterone, 19-norethisterone and norgestrel) in water and urine matrices. During the method development, it has been demonstrated that equilibrium time, ionic strength and back extraction solvents are the most important parameters to control, for determining the nine-hormones in water matrices, in which stir bars coated with 126 microl of polydimethylsiloxane were used. Assays performed on 30 ml water samples spiked at 10 microg/l levels under optimised experimental conditions, yielded recoveries ranging from 11.1+/-4.9% (17beta-estradiol) to 100.2+/-10.4% (mestranol), showed that the methodology is well described by the octanol-water partition coefficients (K(PDMS/W) approximately K(O/W)) for the latter, while pronounced deviations to the theoretical efficiency (K(PDMS/W) not equal K(O/W)) were observed for the remaining hormones. From calibration studies, a good analytical performance for all hormones was attained, including a suitable precision (2.1-17.1%), low limits of detection (0.3-1.0 microg/l) and an excellent linear dynamic range (1.25-50.0 microg/l). Assays on environmental water and urine matrices showed recovery yields in worthy good agreement with the spiking level (10 microg/l), and suitability for profiling low microg/l levels of natural hormones in urine samples taken from pregnant women. The present methodology is easy, reliable and sensitive at the trace level, only requiring a low sample volume, showing to be a good analytical alternative to routine quality control for environmental and biomedical laboratories.

  14. Direct Analysis of Amphetamine Stimulants in a Whole Urine Sample by Atmospheric Solids Analysis Probe Tandem Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Crevelin, Eduardo J.; Salami, Fernanda H.; Alves, Marcela N. R.; De Martinis, Bruno S.; Crotti, Antônio E. M.; Moraes, Luiz A. B.

    2016-05-01

    Amphetamine-type stimulants (ATS) are among illicit stimulant drugs that are most often used worldwide. A major challenge is to develop a fast and efficient methodology involving minimal sample preparation to analyze ATS in biological fluids. In this study, a urine pool solution containing amphetamine, methamphetamine, ephedrine, sibutramine, and fenfluramine at concentrations ranging from 0.5 pg/mL to 100 ng/mL was prepared and analyzed by atmospheric solids analysis probe tandem mass spectrometry (ASAP-MS/MS) and multiple reaction monitoring (MRM). A urine sample and saliva collected from a volunteer contributor (V1) were also analyzed. The limit of detection of the tested compounds ranged between 0.002 and 0.4 ng/mL in urine samples; the signal-to-noise ratio was 5. These results demonstrated that the ASAP-MS/MS methodology is applicable for the fast detection of ATS in urine samples with great sensitivity and specificity, without the need for cleanup, preconcentration, or chromatographic separation. Thus ASAP-MS/MS could potentially be used in clinical and forensic toxicology applications.

  15. Workplace drug testing in Italy: findings about second-stage testing.

    PubMed

    Vignali, Claudia; Stramesi, Cristiana; Morini, Luca; San Bartolomeo, Paolo; Groppi, Angelo

    2015-03-01

    Workplace Drug Testing (WDT) in Italy includes two levels of monitoring: a first stage concerning drug testing on urine samples and a second involving both urine and hair analysis. The second stage is performed only on workers who tested positive at the first level. We analyzed urine and hair specimens from 120 workers undergoing second-level testing between 2009 and 2012. Eighty percent of them had tested positive for cannabinoids during the first level analysis, and 15.8% for cocaine. Both urine and hair samples were analyzed in order to find the following drugs of abuse: amphetamines, buprenorphine, cannabinoids, cocaine, ecstasy, methadone, and opiates. Urine analyses were performed by immunological screening (EMIT); urine confirmatory tests and hair analyses were performed by gas chromatography-mass spectrometry (GC-MS). As regards second-stage testing on urine samples, 71.2% of workers were always negative, whereas 23.9% tested positive at least once for cannabinoids and 2.5% for cocaine. Hair analyses produced surprising results: 61.9% of hair samples tested negative, only 6.2% tested positive for cannabinoids, whereas 28.8% tested positive for cocaine. These findings confirm that second-level surveillance of WDT, which includes hair analysis, is very effective because it highlights drug intake - sometimes heavy - that cannot be revealed only through urine analyses. The employees for whom drug addiction is proved can begin rehabilitation, while keeping their job. Eventually, our results confirmed the widespread and undeclared use of cocaine in Italy. Copyright © 2014 John Wiley & Sons, Ltd.

  16. Direct analysis of δ2H and δ18O in natural and enriched human urine using laser-based, Off-Axis Integrated Cavity Output Spectroscopy

    PubMed Central

    Berman, Elena S.F.; Fortsona, Susan L.; Snaith, Steven P.; Gupta, Manish; Baer, Douglas S.; Chery, Isabelle; Blanc, Stephane; Melanson, Edward L.; Thomson, Peter J; Speakman, John R.

    2012-01-01

    The stable isotopes of hydrogen (δ2H) and oxygen (δ18O) in human urine are measured during studies of total energy expenditure by the doubly labeled water method, measurement of total body water, and measurement of insulin resistance by glucose disposal among other applications. An ultrasensitive laser absorption spectrometer based on off-axis integrated cavity output spectroscopy was demonstrated for simple and inexpensive measurement of stable isotopes in natural isotopic abundance and isotopically enriched human urine. Preparation of urine for analysis was simple and rapid (approx. 25 samples per hour), requiring no decolorizing or distillation steps. Analysis schemes were demonstrated to address sample-to-sample memory while still allowing analysis of 45 natural or 30 enriched urine samples per day. The instrument was linear over a wide range of water isotopes (δ2H = −454 to +1702 ‰ and δ18O= −58.3 to +265 ‰). Measurements of human urine were precise to better than 0.65 ‰ 1σ for δ2H and 0.09 ‰ 1σ for δ18O for natural urines, 1.1 ‰ 1σ for δ2H and 0.13 ‰ 1σ for δ18O for low enriched urines, and 1.0 ‰ 1σ for δ2H and 0.08 ‰ 1σ for δ18O for high enriched urines. Furthermore, the accuracy of the isotope measurements of human urines was verified to better than ±0.81 ‰ in δ2H and ±0.13 ‰ in δ18O (average deviation) against three independent IRMS laboratories. The ability to immediately and inexpensively measure the stable isotopes of water in human urine is expected to increase the number and variety of experiments which can be undertaken. PMID:23075099

  17. Accuracy of urinary human papillomavirus testing for presence of cervical HPV: systematic review and meta-analysis

    PubMed Central

    Pathak, Neha; Dodds, Julie; Khan, Khalid

    2014-01-01

    Objective To determine the accuracy of testing for human papillomavirus (HPV) DNA in urine in detecting cervical HPV in sexually active women. Design Systematic review and meta-analysis. Data sources Searches of electronic databases from inception until December 2013, checks of reference lists, manual searches of recent issues of relevant journals, and contact with experts. Eligibility criteria Test accuracy studies in sexually active women that compared detection of urine HPV DNA with detection of cervical HPV DNA. Data extraction and synthesis Data relating to patient characteristics, study context, risk of bias, and test accuracy. 2×2 tables were constructed and synthesised by bivariate mixed effects meta-analysis. Results 16 articles reporting on 14 studies (1443 women) were eligible for meta-analysis. Most used commercial polymerase chain reaction methods on first void urine samples. Urine detection of any HPV had a pooled sensitivity of 87% (95% confidence interval 78% to 92%) and specificity of 94% (95% confidence interval 82% to 98%). Urine detection of high risk HPV had a pooled sensitivity of 77% (68% to 84%) and specificity of 88% (58% to 97%). Urine detection of HPV 16 and 18 had a pooled sensitivity of 73% (56% to 86%) and specificity of 98% (91% to 100%). Metaregression revealed an increase in sensitivity when urine samples were collected as first void compared with random or midstream (P=0.004). Limitations The major limitations of this review are the lack of a strictly uniform method for the detection of HPV in urine and the variation in accuracy between individual studies. Conclusions Testing urine for HPV seems to have good accuracy for the detection of cervical HPV, and testing first void urine samples is more accurate than random or midstream sampling. When cervical HPV detection is considered difficult in particular subgroups, urine testing should be regarded as an acceptable alternative. PMID:25232064

  18. [Is the renal excretion of orally applied diatrizoate (Gastrografin) a reliable marker of gastrointestinal perforation or dehiscence of a gastrointestinal anastomosis?].

    PubMed

    Born, M; Axmann, C; Kader, R; von Falkenhausen, M; Manka, C; Willinek, W A; Schild, H

    2004-11-01

    Renal excretion of orally or rectally applied Gastrografin is reported to be a reliable indicator of a perforation or a postoperative anastomotic dehiscence of the GI-tract. The study was conducted to determine whether increased attenuation of the urine measured by CT after oral or rectal application of Gastrografin can give reliable evidence of any leakage from the gastrointestinal tract. Urine samples of 33 patients, who underwent a Gastrografin-enhanced fluoroscopic examination of the esophagus or the GI-tract for different clinical reasons, were examined by CT. The samples had been taken immediately before and 60 to 90 minutes after application of 100 ml Gastrografin. The results were compared with those of 5 healthy volunteers, who took urine samples before, 30, 60, 90, and 120 minutes after drinking 100 ml of Gastrografin. Maximal attenuation of the volunteers' urine samples was achieved 60 to 90 minutes after Gastrografin application with a mean of 50 Hounsfield units (HU), SD = 17 HU. The urine of three patients with radiologically proven fistula or dehiscence of a GI-tract anastomosis had no relevant increase in attenuation. Three other cases without any clinical or radiological evidence of an anastomotic leak had a substantial increase in the attenuation of the urine probes (87, 110, and 290 HU, respectively). The CT-measured urine samples as evidence of renal excretion of orally or rectally applied Gastrografin are not reliable for the detection of leaks from the GI-tract.

  19. Application of drug testing using exhaled breath for compliance monitoring of drug addicts in treatment.

    PubMed

    Carlsson, Sten; Olsson, Robert; Lindkvist, Irene; Beck, Olof

    2015-04-01

    Exhaled breath has recently been identified as a possible matrix for drug testing. This study explored the potential of this new method for compliance monitoring of patients being treated for dependence disorders. Outpatients in treatment programs were recruited for this study. Urine was collected as part of clinical routine and a breath sample was collected in parallel together with a questionnaire about their views of the testing procedure. Urine was analyzed for amphetamines, benzodiazepines, cannabis, cocaine, buprenorphine, methadone and opiates using CEDIA immunochemical screening and mass spectrometry confirmation. The exhaled breath was collected using the SensAbues device and analyzed by mass spectrometry for amphetamine, methamphetamine, diazepam, oxazepam, tetrahydrocannabinol, cocaine, benzoylecgonine, buprenorphine, methadone, morphine, codeine and 6-acetylmorphine. A total of 122 cases with parallel urine and breath samples were collected; 34 of these were negative both in urine and breath. Out of 88 cases with positive urine samples 51 (58%) were also positive in breath. Among the patients on methadone treatment, all were positive for methadone in urine and 83% were positive in breath. Among patients in treatment with buprenorphine, 92% were positive in urine and among those 80% were also positive in breath. The questionnaire response documented that in general, patients accepted drug testing well and that the breath sampling procedure was preferred. Compliance testing for the intake of prescribed and unprescribed drugs among patients in treatment for dependence disorders using the exhaled breath sampling technique is a viable method and deserves future attention.

  20. Detection of Intracellular Bacterial Communities in Human Urinary Tract Infection

    PubMed Central

    Rosen, David A; Hooton, Thomas M; Stamm, Walter E; Humphrey, Peter A; Hultgren, Scott J

    2007-01-01

    Background Urinary tract infections (UTIs) are one of the most common bacterial infections and are predominantly caused by uropathogenic Escherichia coli (UPEC). While UTIs are typically considered extracellular infections, it has been recently demonstrated that UPEC bind to, invade, and replicate within the murine bladder urothelium to form intracellular bacterial communities (IBCs). These IBCs dissociate and bacteria flux out of bladder facet cells, some with filamentous morphology, and ultimately establish quiescent intracellular reservoirs that can seed recurrent infection. This IBC pathogenic cycle has not yet been investigated in humans. In this study we sought to determine whether evidence of an IBC pathway could be found in urine specimens from women with acute UTI. Methods and Findings We collected midstream, clean-catch urine specimens from 80 young healthy women with acute uncomplicated cystitis and 20 asymptomatic women with a history of UTI. Investigators were blinded to culture results and clinical history. Samples were analyzed by light microscopy, immunofluorescence, and electron microscopy for evidence of exfoliated IBCs and filamentous bacteria. Evidence of IBCs was found in 14 of 80 (18%) urines from women with UTI. Filamentous bacteria were found in 33 of 80 (41%) urines from women with UTI. None of the 20 urines from the asymptomatic comparative group showed evidence of IBCs or filaments. Filamentous bacteria were present in all 14 of the urines with IBCs compared to 19 (29%) of 66 samples with no evidence of IBCs (p < 0.001). Of 65 urines from patients with E. coli infections, 14 (22%) had evidence of IBCs and 29 (45%) had filamentous bacteria, while none of the gram-positive infections had IBCs or filamentous bacteria. Conclusions The presence of exfoliated IBCs and filamentous bacteria in the urines of women with acute cystitis suggests that the IBC pathogenic pathway characterized in the murine model may occur in humans. The findings support the occurrence of an intracellular bacterial niche in some women with cystitis that may have important implications for UTI recurrence and treatment. PMID:18092884

  1. Identification of HIV-1 genitourinary tract compartmentalization by analyzing the env gene sequences in urine.

    PubMed

    Blasi, Maria; Carpenter, J Harris; Balakumaran, Bala; Cara, Andrea; Gao, Feng; Klotman, Mary E

    2015-08-24

    HIV-1 persists indefinitely in memory CD4 T cells and other long-lived cellular reservoirs despite antiretroviral therapy. Our group had previously demonstrated that HIV-1 can establish a productive infection in renal epithelial cells and that the kidney represents a separate compartment for HIV-1 replication. Here, to better understand the viruses in this unique site, we genetically characterized and compared the viruses in blood and urine specimens from 24 HIV-1 infected patients with detectable viremia. Blood and urine samples were obtained from 35 HIV-1 positive patients. Single-genome amplification was performed on HIV-1 env RNA and DNA isolated from urine supernatants and urine-derived cell pellets, respectively, as well as from plasma and peripheral blood mononuclear cell from the same individuals. Neighbor-joining trees were constructed under the Kimura 2-parameter model. We amplified and sequenced the full-length HIV-1 envelope (env) gene from 12 of the 24 individuals, indicating that 50% of the viremic HIV-1-positive patients had viral RNA in their urine. Phylogenetic analysis of the env sequences from four individuals with more than 15 urine-derived env sequences showed that the majority of the sequences from urine formed distinct cluster(s) independent of those peripheral blood mononuclear cell and plasma-derived sequences, consistent with viral compartmentalization in the urine. Our results suggest the presence of a distinct HIV compartment in the genitourinary tract.

  2. Identification of HIV-1 Genitourinary Tract Compartmentalization by Analyzing the env Gene Sequences in Urine

    PubMed Central

    BLASI, Maria; CARPENTER, J. Harris; BALAKUMARAN, Bala; CARA, Andrea; GAO, Feng; KLOTMAN, Mary E.

    2015-01-01

    Objective HIV-1 persists indefinitely in memory CD4+ T cells and other long-lived cellular reservoirs despite antiretroviral therapy (ART). Our group had previously demonstrated that HIV-1 can establish a productive infection in renal epithelial cells and that the kidney represents a separate compartment for HIV-1 replication. Here, to better understand the viruses in this unique site, we genetically characterized and compared the viruses in blood and urine specimens from twenty-four HIV-1 infected subjects with detectable viremia. Design and Methods Blood and urine samples were obtained from 35 HIV-1 positive subjects. Single-genome amplification was performed on HIV-1 env RNA and DNA isolated from urine supernatants and urine derived cell pellets respectively, as well as from plasma and PBMC from the same individuals. Neighbor-joining trees were constructed under the Kimura 2-parameter mode. Results We amplified and sequenced the full-length HIV-1 envelope (env) gene from twelve of the twenty-four individuals, indicating that fifty percent (50%) of the viremic HIV-1 positive patients had viral RNA in their urine. Phylogenetic analysis of the env sequences from four subjects with more than fifteen urine-derived env sequences showed that the majority of the sequences from urine formed distinct cluster(s) independent of those PBMC and plasma-derived sequences, consistent with viral compartmentalization in the urine. Conclusions Our results suggest the presence of a distinct HIV compartment in the genitourinary tract. PMID:26372275

  3. Genotyping for DQA1 and PM loci in urine using PCR-based amplification: effects of sample volume, storage temperature, preservatives, and aging on DNA extraction and typing.

    PubMed

    Vu, N T; Chaturvedi, A K; Canfield, D V

    1999-05-31

    Urine is often the sample of choice for drug screening in aviation/general forensic toxicology and in workplace drug testing. In some instances, the origin of the submitted samples may be challenged because of the medicolegal and socioeconomic consequences of a positive drug test. Methods for individualization of biological samples have reached a new boundary with the application of the polymerase chain reaction (PCR) in DNA profiling, but a successful characterization of the urine specimens depends on the quantity and quality of DNA present in the samples. Therefore, the present study investigated the influence of storage conditions, sample volume, concentration modes, extraction procedures, and chemical preservations on the quantity of DNA recovered, as well as the success rate of PCR-based genotyping for DQA1 and PM loci in urine. Urine specimens from male and female volunteers were divided and stored at various temperatures for up to 30 days. The results suggested that sample purification by dialfiltration, using 3000-100,000 molecular weight cut-off filters, did not enhance DNA recovery and typing rate as compared with simple centrifugation procedures. Extraction of urinary DNA by the organic method and by the resin method gave comparable typing results. Larger sample volume yielded a higher amount of DNA, but the typing rates were not affected for sample volumes between 1 and 5 ml. The quantifiable amounts of DNA present were found to be greater in female (14-200 ng/ml) than in male (4-60 ng/ml) samples and decreased with the elapsed time under both room temperature (RT) and frozen storage. Typing of the male samples also demonstrated that RT storage samples produced significantly higher success rates than that of frozen samples, while there was only marginal difference in the DNA typing rates among the conditions tested using female samples. Successful assignment of DQA1 + PM genotype was achieved for all samples of fresh urine, independent of gender, starting sample volume, or concentration method. Preservation by 0.25% sodium azide was acceptable for sample storage at 4 degrees C during a period of 30 days. For longer storage duration, freezing at -70 degrees C may be more appropriate. Thus, the applicability of the DQA1 + PM typing was clearly demonstrated for individualization of urine samples.

  4. Association between urine fluoride and dental fluorosis as a toxicity factor in a rural community in the state of San Luis Potosi.

    PubMed

    Jarquín-Yañez, Lizet; de Jesús Mejía-Saavedra, José; Molina-Frechero, Nelly; Gaona, Enrique; Rocha-Amador, Diana Olivia; López-Guzmán, Olga Dania; Bologna-Molina, Ronell

    2015-01-01

    The aim of this study is to investigate urine fluoride concentration as a toxicity factor in a rural community in the state of San Luis Potosi, Mexico. A sample of 111 children exposed to high concentrations of fluoride in drinking water (4.13 mg/L) was evaluated. Fluoride exposure was determined by measuring urine fluoride concentration using the potentiometric method with an ion selective electrode. The diagnosis of dental fluorosis was performed by clinical examination, and the severity of damage was determined using Dean's index and the Thylstrup-Fejerskov (TF) index. The range of exposure in the study population, evaluated through the fluoride content in urine, was 1.1 to 5.9 mg/L, with a mean of 3.14±1.09 mg/L. Dental fluorosis was present in all subjects, of which 95% had severe cases. Higher urine fluoride levels and greater degrees of severity occurred in older children. The results show that dental fluorosis was determined by the presence of fluoride exposure finding a high positive correlation between the severity of fluorosis and urine fluoride concentration and the years of exposure suggested a cumulative effect.

  5. Identification of urinary tract pathogens after 3-hours urine culture by MALDI-TOF mass spectrometry.

    PubMed

    Haiko, Johanna; Savolainen, Laura E; Hilla, Risto; Pätäri-Sampo, Anu

    2016-10-01

    Complicated urinary tract infections, such as pyelonephritis, may lead to sepsis. Rapid diagnosis is needed to identify the causative urinary pathogen and to verify the appropriate empirical antimicrobial therapy. We describe here a rapid identification method for urinary pathogens: urine is incubated on chocolate agar for 3h at 35°C with 5% CO2 and subjected to MALDI-TOF MS analysis by VITEK MS. Overall 207 screened clinical urine samples were tested in parallel with conventional urine culture. The method, called U-si-MALDI-TOF (urine short incubation MALDI-TOF), showed correct identification for 86% of Gram-negative urinary tract pathogens (Escherichia coli, Klebsiella pneumoniae, and other Enterobacteriaceae), when present at >10(5)cfu/ml in culture (n=107), compared with conventional culture method. However, Gram-positive bacteria (n=28) were not successfully identified by U-si-MALDI-TOF. This method is especially suitable for rapid identification of E. coli, the most common cause of urinary tract infections and urosepsis. Turnaround time for identification using U-si-MALDI-TOF compared with conventional urine culture was improved from 24h to 4-6h. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Coca tea consumption causes positive urine cocaine assay.

    PubMed

    Mazor, Suzan S; Mycyk, Mark B; Wills, Brandon K; Brace, Larry D; Gussow, Leon; Erickson, Timothy

    2006-12-01

    Coca tea, derived from the same plant that is used to synthesize cocaine, is commonly consumed in South America and easily obtained in the United States. To determine whether consumption of coca tea would result in a positive urine toxicology screen for cocaine metabolites. Five healthy adult volunteers consumed coca tea and underwent serial quantitative urine testing for cocaine metabolites by fluorescence polarization immunoassay. The cutoff for a positive assay was chosen at 300 ng/ml, the National Institute on Drug Abuse standard. Each participant's urine cocaine assay was positive (level exceeding 300 ng/ml) by 2 h after ingestion. Three out of five participants' samples remained positive at 36 h. Mean urine benzoylecgonine concentrations in all postconsumption samples was 1777 ng/ml (95% confidence interval: 1060-2495). Coca tea ingestion resulted in a positive urine assay for cocaine metabolite. Healthcare professionals should consider a history of coca tea ingestion when interpreting urine toxicology results.

  7. Potential of non-invasive esophagus cancer detection based on urine surface-enhanced Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Huang, Shaohua; Wang, Lan; Chen, Weisheng; Feng, Shangyuan; Lin, Juqiang; Huang, Zufang; Chen, Guannan; Li, Buhong; Chen, Rong

    2014-11-01

    Non-invasive esophagus cancer detection based on urine surface-enhanced Raman spectroscopy (SERS) analysis was presented. Urine SERS spectra were measured on esophagus cancer patients (n = 56) and healthy volunteers (n = 36) for control analysis. Tentative assignments of the urine SERS spectra indicated some interesting esophagus cancer-specific biomolecular changes, including a decrease in the relative content of urea and an increase in the percentage of uric acid in the urine of esophagus cancer patients compared to that of healthy subjects. Principal component analysis (PCA) combined with linear discriminant analysis (LDA) was employed to analyze and differentiate the SERS spectra between normal and esophagus cancer urine. The diagnostic algorithms utilizing a multivariate analysis method achieved a diagnostic sensitivity of 89.3% and specificity of 83.3% for separating esophagus cancer samples from normal urine samples. These results from the explorative work suggested that silver nano particle-based urine SERS analysis coupled with PCA-LDA multivariate analysis has potential for non-invasive detection of esophagus cancer.

  8. Metabolomics reveals dose effects of low-dose chronic exposure to uranium in rats: identification of candidate biomarkers in urine samples.

    PubMed

    Grison, Stéphane; Favé, Gaëlle; Maillot, Matthieu; Manens, Line; Delissen, Olivia; Blanchardon, Éric; Dublineau, Isabelle; Aigueperse, Jocelyne; Bohand, Sandra; Martin, Jean-Charles; Souidi, Maâmar

    2016-01-01

    Data are sparse about the potential health risks of chronic low-dose contamination of humans by uranium (natural or anthropogenic) in drinking water. Previous studies report some molecular imbalances but no clinical signs due to uranium intake. In a proof-of-principle study, we reported that metabolomics is an appropriate method for addressing this chronic low-dose exposure in a rat model (uranium dose: 40 mg L -1 ; duration: 9 months, n = 10). In the present study, our aim was to investigate the dose-effect pattern and identify additional potential biomarkers in urine samples. Compared to our previous protocol, we doubled the number of rats per group (n = 20), added additional sampling time points (3 and 6 months) and included several lower doses of natural uranium (doses used: 40, 1.5, 0.15 and 0.015 mg L -1 ). LC-MS metabolomics was performed on urine samples and statistical analyses were made with SIMCA-P+ and R packages. The data confirmed our previous results and showed that discrimination was both dose and time related. Uranium exposure was revealed in rats contaminated for 9 months at a dose as low as 0.15 mg L -1 . Eleven features, including the confidently identified N1-methylnicotinamide, N1-methyl-2-pyridone-5-carboxamide and 4-hydroxyphenylacetylglycine, discriminated control from contaminated rats with a specificity and a sensitivity ranging from 83 to 96 %, when combined into a composite score. These findings show promise for the elucidation of underlying radiotoxicologic mechanisms and the design of a diagnostic test to assess exposure in urine, in a dose range experimentally estimated to be above a threshold between 0.015 and 0.15 mg L -1 .

  9. Pre-analytical Factors Influence Accuracy of Urine Spot Iodine Assessment in Epidemiological Surveys.

    PubMed

    Doggui, Radhouene; El Ati-Hellal, Myriam; Traissac, Pierre; El Ati, Jalila

    2018-03-26

    Urinary iodine concentration (UIC) is commonly used to assess iodine status of subjects in epidemiological surveys. As pre-analytical factors are an important source of measurement error and studies about this phase are scarce, our objective was to assess the influence of urine sampling conditions on UIC, i.e., whether the child ate breakfast or not, urine void rank of the day, and time span between last meal and urine collection. A nationwide, two-stage, stratified, cross-sectional study including 1560 children (6-12 years) was performed in 2012. UIC was determined by the Sandell-Kolthoff method. Pre-analytical factors were assessed from children's mothers by using a questionnaire. Association between iodine status and pre-analytical factors were adjusted for one another and socio-economic characteristics by multivariate linear and multinomial regression models (RPR: relative prevalence ratios). Skipping breakfast prior to morning urine sampling decreased UIC by 40 to 50 μg/L and the proportion of UIC < 100 μg/L was higher among children having those skipped breakfast (RPR = 3.2[1.0-10.4]). In unadjusted analyses, UIC was less among children sampled more than 5 h from their last meal. UIC decreased with rank of urine void (e.g., first vs. second, P < 0.001); also, the proportion of UIC < 100 μg/L was greater among 4th rank samples (vs. second RPR = 2.1[1.1-4.0]). Subjects' breakfast status and urine void rank should be accounted for when assessing iodine status. Providing recommendations to standardize pre-analytical factors is a key step toward improving accuracy and comparability of survey results for assessing iodine status from spot urine samples. These recommendations have to be evaluated by future research.

  10. Evaluation of take-home organophosphorus pesticide exposure among agricultural workers and their children.

    PubMed Central

    Curl, Cynthia L; Fenske, Richard A; Kissel, John C; Shirai, Jeffry H; Moate, Thomas F; Griffith, William; Coronado, Gloria; Thompson, Beti

    2002-01-01

    We analyzed organophosphorus pesticide exposure in 218 farm worker households in agricultural communities in Washington State to investigate the take-home pathway of pesticide exposure and to establish baseline exposure levels for a community intervention project. House dust samples (n = 156) were collected from within the homes, and vehicle dust samples (n = 190) were collected from the vehicles used by the farm workers to commute to and from work. Urine samples were obtained from a farm worker (n = 213) and a young child (n = 211) in each household. Dust samples were analyzed for six pesticides, and urine samples were analyzed for five dialkylphosphate (DAP) metabolites. Azinphosmethyl was detected in higher concentrations (p < 0.0001) than the other pesticides: geometric mean concentrations of azinphosmethyl were 0.53 micro g/g in house dust and 0.75 micro g/g in vehicle dust. Dimethyl DAP metabolite concentrations were higher than diethyl DAP metabolite concentrations in both child and adult urine (p < 0.0001). Geometric mean dimethyl DAP concentrations were 0.13 micro mol/L in adult urine and 0.09 micro mol/L in child urine. Creatinine-adjusted geometric mean dimethyl DAP concentrations were 0.09 micro mol/g in adult urine and 0.14 micro mol/g in child urine. Azinphosmethyl concentrations in house dust and vehicle dust from the same household were significantly associated (r2 = 0.41, p < 0.0001). Dimethyl DAP levels in child and adult urine from the same household were also significantly associated (r2 = 0.18, p < 0.0001), and this association remained when the values were creatinine adjusted. The results of this work support the hypothesis that the take-home exposure pathway contributes to residential pesticide contamination in agricultural homes where young children are present. PMID:12460819

  11. Human urine as test material in 1H NMR-based metabonomics: recommendations for sample preparation and storage.

    PubMed

    Lauridsen, Michael; Hansen, Steen H; Jaroszewski, Jerzy W; Cornett, Claus

    2007-02-01

    Metabonomic approaches are believed to have the capability of revolutionizing diagnosis of diseases and assessment of patient conditions after medical interventions. In order to ensure comparability of metabonomic 1H NMR data from different studies, we suggest validated sample preparation guidelines for human urine based on a stability study that evaluates effects of storage time and temperature, freeze-drying, and the presence of preservatives. The results indicated that human urine samples should be stored at or below -25 degrees C, as no changes in the 1H NMR fingerprints have been observed during storage at this temperature for 26 weeks. Formation of acetate, presumably due to microbial contamination, was occasionally observed in samples stored at 4 degrees C without addition of a preservative. Addition of a preserving agent is not mandatory provided that the samples are stored at -25 degrees C. Thus, no differences were observed between 1H NMR spectra of nonpreserved urines and urines with added sodium azide and stored at -25 degrees C, whereas the presence of sodium fluoride caused a shift of especially citrate resonances. Freeze-drying of urine and reconstitution in D2O at pH 7.4 resulted in the disappearance of the creatinine CH2 signal at delta 4.06 due to deuteration. A study evaluating the effects of phosphate buffer concentration on signal variability and assessment of the probability of citrate or creatinine resonances crossing bucket border (a boundary between adjacent integrated regions) led to the conclusion that a minimum buffer concentration of 0.3 M is adequate for normal urines used in this study. However, final buffer concentration of 1 M will be required for very concentrated urines.

  12. Urine Monitoring System

    NASA Technical Reports Server (NTRS)

    Feedback, Daniel L.; Cibuzar, Branelle R.

    2009-01-01

    The Urine Monitoring System (UMS) is a system designed to collect an individual crewmember's void, gently separate urine from air, accurately measure void volume, allow for void sample acquisition, and discharge remaining urine into the Waste Collector Subsystem (WCS) onboard the International Space Station. The Urine Monitoring System (UMS) is a successor design to the existing Space Shuttle system and will resolve anomalies such as: liquid carry-over, inaccurate void volume measurements, and cross contamination in void samples. The crew will perform an evaluation of airflow at the ISS UMS urinal hose interface, a calibration evaluation, and a full user interface evaluation. o The UMS can be used to facilitate non-invasive methods for monitoring crew health, evaluation of countermeasures, and implementation of a variety of biomedical research protocols on future exploration missions.

  13. Stability and reproducibility of a single-sample urinary C-peptide/creatinine ratio and its correlation with 24-h urinary C-peptide.

    PubMed

    McDonald, Tim J; Knight, Bridget A; Shields, Beverley M; Bowman, Pamela; Salzmann, Maurice B; Hattersley, Andrew T

    2009-11-01

    C-peptide measurement in blood or 24-h urine samples provides useful information regarding endogenous insulin secretion, but problems related to the rapid degradation of C-peptide in blood and difficulty of 24-h urine collection have limited widespread routine clinical use of this test. We assessed the feasibility of measuring urinary C-peptide (UCP) with correction for creatinine concentration in single urine samples. We analyzed UCP using a routine electrochemiluminescence immunoassay in samples from 21 healthy volunteers. We investigated the stability of UCP with different preservatives and storage conditions and compared the reproducibility of urinary C-peptide/creatinine ratio (UCPCR) in first- and second-void fasting urines, then assessed correlations with 24-h collections. UCPCR was unchanged at room temperature for 24 h and at 4 degrees C for 72 h even in the absence of preservative. UCPCR collected in boric acid was stable at room temperature for 72 h. UCPCR remained stable after 7 freeze-thaw cycles but decreased with freezer storage time and dropped to 82%-84% of baseline by 90 days at -20 degrees C. Second-void fasting UCPCRs were lower than first-void (median 0.78 vs 1.31, P = 0.0003) and showed less variation (CV 33% vs 52%), as second-void UCPCRs were not influenced by evening food-related insulin secretion. Second-void fasting UCPCR was highly correlated with 24-h UCP (r = 0.8, P = 0.00006). Second-void fasting UCPCR is a reproducible measure that correlates well with 24-h UCP in normal samples. The 3-day stability of UCPCR at room temperature greatly increases its potential clinical utility.

  14. Evaluating levels and health risk of heavy metals in exposed workers from surgical instrument manufacturing industries of Sialkot, Pakistan.

    PubMed

    Junaid, Muhammad; Hashmi, Muhammad Zaffar; Malik, Riffat Naseem

    2016-09-01

    The study aimed to monitor heavy metal (chromium, Cr; cadmium, Cd; nickel, Ni; copper, Cu; lead, Pb; iron, Fe; manganese, Mn; and zinc, Zn) footprints in biological matrices (urine, whole blood, saliva, and hair), as well as in indoor industrial dust samples, and their toxic effects on oxidative stress and health risks in exposed workers. Overall, blood, urine, and saliva samples exhibited significantly higher concentrations of toxic metals in exposed workers (Cr; blood 16.30 μg/L, urine 58.15 μg/L, saliva 5.28 μg/L) than the control samples (Cr; blood 5.48 μg/L, urine 4.47 μg/L, saliva 2.46 μg/L). Indoor industrial dust samples also reported to have elevated heavy metal concentrations, as an example, Cr quantified with concentration of 299 mg/kg of dust, i.e., more than twice the level of Cr in household dust (136 mg/kg). Superoxide dismutase (SOD) level presented significant positive correlation (p ≤ 0.01) with Cr, Zn, and Cd (Cr > Zn > Cd) which is an indication of heavy metal's associated raised oxidative stress in exposed workers. Elevated average daily intake (ADI) of heavy metals resulted in cumulative hazard quotient (HQ) range of 2.97-18.88 in workers of different surgical units; this is an alarming situation of health risk implications. Principal component analysis-multiple linear regression (PCA-MLR)-based pie charts represent that polishing and cutting sections exhibited highest metal inputs to the biological and environmental matrices than other sources. Heavy metal concentrations in biological matrices and dust samples showed a significant positive correlation between Cr in dust, urine, and saliva samples. Current study will help to generate comprehensive base line data of heavy metal status in biomatrices and dust from scientifically ignored industrial sector. Our findings can play vital role for health departments and industrial environmental management system (EMS) authorities in policy making and implementation.

  15. Excreta Sampling as an Alternative to In Vivo Measurements at the Hanford Site.

    PubMed

    Carbaugh, Eugene H; Antonio, Cheryl L; Lynch, Timothy P

    2015-08-01

    The capabilities of indirect radiobioassay by urine and fecal sample analysis were compared with the direct radiobioassay methods of whole body counting and lung counting for the most common radionuclides and inhalation exposure scenarios encountered by Hanford workers. Radionuclides addressed by in vivo measurement included 137Cs, 60Co, 154Eu, and 241Am as an indicator for plutonium mixtures. The same radionuclides were addressed using gamma energy analysis of urine samples, augmented by radiochemistry and alpha spectrometry methods for plutonium in urine and fecal samples. It was concluded that in vivo whole body counting and lung counting capability should be maintained at the Hanford Site for the foreseeable future, however, urine and fecal sample analysis could provide adequate, though degraded, monitoring capability for workers as a short-term alternative, should in vivo capability be lost due to planned or unplanned circumstances.

  16. The use of laser-induced fluorescence or ultraviolet detectors for sensitive and selective analysis of tobramycin or erythropoietin in complex samples

    NASA Astrophysics Data System (ADS)

    Ahmed, Hytham M.; Ebeid, Wael B.

    2015-05-01

    Complex samples analysis is a challenge in pharmaceutical and biopharmaceutical analysis. In this work, tobramycin (TOB) analysis in human urine samples and recombinant human erythropoietin (rhEPO) analysis in the presence of similar protein were selected as representative examples of such samples analysis. Assays of TOB in urine samples are difficult because of poor detectability. Therefore laser induced fluorescence detector (LIF) was combined with a separation technique, micellar electrokinetic chromatography (MEKC), to determine TOB through derivatization with fluorescein isothiocyanate (FITC). Borate was used as background electrolyte (BGE) with negative-charged mixed micelles as additive. The method was successively applied to urine samples. The LOD and LOQ for Tobramycin in urine were 90 and 200 ng/ml respectively and recovery was >98% (n = 5). All urine samples were analyzed by direct injection without sample pre-treatment. Another use of hyphenated analytical technique, capillary zone electrophoresis (CZE) connected to ultraviolet (UV) detector was also used for sensitive analysis of rhEPO at low levels (2000 IU) in the presence of large amount of human serum albumin (HSA). Analysis of rhEPO was achieved by the use of the electrokinetic injection (EI) with discontinuous buffers. Phosphate buffer was used as BGE with metal ions as additive. The proposed method can be used for the estimation of large number of quality control rhEPO samples in a short period.

  17. Urine sampling and collection system optimization and testing

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Geating, J. A.; Koesterer, M. G.

    1975-01-01

    A Urine Sampling and Collection System (USCS) engineering model was developed to provide for the automatic collection, volume sensing and sampling of urine from each micturition. The purpose of the engineering model was to demonstrate verification of the system concept. The objective of the optimization and testing program was to update the engineering model, to provide additional performance features and to conduct system testing to determine operational problems. Optimization tasks were defined as modifications to minimize system fluid residual and addition of thermoelectric cooling.

  18. Pilot-Plant Demonstration of Wet Oxidation for Treatment of Shipboard Wastewaters.

    DTIC Science & Technology

    1975-11-01

    minus mg of COD removed in prior sampling )] Table I indicates that, when the reactor was last sampled after six injections Pf concentrated feces and urine ...oxidation of feces and urine is of an inorganic nature. The pH of most of the samples taken in thes tests was measured using indi- cator papers. All...BATCH EXPERIMENTS ON FECES AND URINE IN rRESENCE OF BARBER-COLMAN CO. CATALYST 10,480 ............. . E.1 lest Procedure ......... . E-3 E.2 Test

  19. Epidemiological investigation of the UGT2B17 polymorphism in doping control urine samples and its correlation to T/E ratios.

    PubMed

    Anielski, Patricia; Simmchen, Juliane; Wassill, Lars; Ganghofner, Dirk; Thieme, Detlef

    2011-10-01

    The deletion polymorphism of the enzyme UGT2B17 is known to correlate with the level of the testosterone to epitestosterone (T/E) ratio in urine specimen. Due to the importance of the T/E ratio to detect testosterone abuse in doping analysis, a PCR-ELISA system (Genotype® UGT test, AmplexDiagnostics) was established to identify the UGT2B17 phenotype in urine samples. Epidemiological investigations in a set of 674 routine doping controls (in- and out-of-competition) resulted in 22.8% homozygote gene-deleted and 74.5% UGT2B17-positive athletes. The validated test system has shown to be robust and sensitive: in only 18 cases (2.7%) isolation of cell material from urine failed. Following hydrolysis of glucuronidated conjugates, steroids were analyzed as bis-TMS derivatives by gas chromatography-mass spectrometry (GC-MS), for example, testosterone (T) and epitestosterone (E). Additionally, isotope ration mass spectrometry (IRMS) analysis and luteinizing hormone (LH) measurement were applied. Mean T/E ratios significantly correlated with the UGT2B17 phenotype (del: T/E 0.9; pos: 1.7), however the values did not differ as distinctive as reported in previous studies. Additionally, the T/E ratios in the gene-deleted group did not show a normal curve of distribution (median of T/E 0.5). Obviously, beside the UGT2B17 deletion further influences have to be taken into account, for example, polymorphisms or induction of other metabolizing enzymes. Our results indicate that the UGT2B17 polymorphism might be insufficient when utilized solely as a crucial parameter for individual interpretation of T/E in urine. Nevertheless, the detection of the UGT2B17-gene deletion in urine samples would provide additional information important for gathering evidence in analysis of steroids in doping control. Copyright © 2011 John Wiley & Sons, Ltd.

  20. Investigation of magnetic nanoparticles for the rapid extraction and assay of alpha-emitting radionuclides from urine: Demonstration of a novel radiobioassay method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Hara, Matthew J.; Carter, Jennifer C.; Maclellan, Jay A.

    2011-08-01

    In the event of an accidental or intentional release of radionuclides into a populated area, three things must occur in a timely manner: food and drinking water supplies must be determined to be safe to eat / drink, civilians and/or military personnel must be surveyed to ensure that they do not have external contamination, and they must be screened to ensure that significant ingestion or inhalation of radionuclides has not occurred (this paper is concerned with the latter). In the event of such a disaster, the volume of radiobioassays to be performed would be tremendous. If the event released significantmore » levels of β- or α-emitting radionuclides, in vivo assays would be ineffective. Therefore, highly efficient and rapid analytical methods for radionuclide detection from submitted spot urine samples (≤ 50 mL) would be required. At present, the quantitative determination of α-emitting radionuclides from urine samples is highly labor intensive, and requires significant sample preparation and analysis time. Sorbent materials that provide effective collection and enable rapid assay could significantly streamline the radioanalytical process. We have demonstrated the use of paramagnetic nanoparticles as a novel class of extracting media for four α-emitting radionuclides of concern (Po, Ra, Am, and U) from chemically unmodified and pH 2 human urine. Herein the initial experimental sorption results are presented along with a novel method that utilizes paramagnetic nanoparticles for the extraction of radionuclides from unmodified human urine followed by the magnetic field-induced collection of the particles for subsequent α-counting-source preparation. Additionally, we construct a versatile human dose model that determines the detector count times required to estimate internal human dose at specific protective action thresholds. The model provides a means to assess a method’s detection capabilities and use fundamental health physics parameters and actual experimental data as core variables. The modeling shows that with effective sorbent materials, rapid screening for internalized α-emitters is possible from a 50 mL spot urine sample volume collected within one week of exposure/intake.« less

  1. Comparison of Cobas 6500 and Iris IQ200 fully-automated urine analyzers to manual urine microscopy

    PubMed Central

    Bakan, Ebubekir; Ozturk, Nurinnisa; Baygutalp, Nurcan Kilic; Polat, Elif; Akpinar, Kadriye; Dorman, Emrullah; Polat, Harun; Bakan, Nuri

    2016-01-01

    Introduction Urine screening is achieved by either automated or manual microscopic analysis. The aim of the study was to compare Cobas 6500 and Iris IQ200 urine analyzers, and manual urine microscopic analysis. Materials and methods A total of 540 urine samples sent to the laboratory for chemical and sediment analysis were analyzed on Cobas 6500 and Iris IQ200 within 1 hour from sampling. One hundred and fifty three samples were found to have pathological sediment results and were subjected to manual microscopic analysis performed by laboratory staff blinded to the study. Spearman’s and Gamma statistics were used for correlation analyses, and the McNemar test for the comparison of the two automated analyzers. Results The comparison of Cobas u701 to the manual method yielded the following regression equations: y = - 0.12 (95% CI: - 1.09 to 0.67) + 0.78 (95% CI: 0.65 to 0.95) x for WBC and y = 0.06 (95% CI: - 0.09 to 0.25) + 0.66 (95% CI: 0.57 to 0.73) x for RBC. The comparison of IQ200 Elite to manual method the following equations: y = 0.03 (95% CI: - 1.00 to 1.00) + 0.88 (95% CI: 0.66 to 1.00) x for WBC and y = - 0.22 (95% CI: - 0.80 to 0.20) + 0.40 (95% CI: 0.32 to 0.50) x for RBC. IQ200 Elite compared to Cobas u701 yielded the following equations: y = - 0.95 (95% CI: - 2.13 to 0.11) + 1.25 (95% CI: 1.08 to 1.44) x for WBC and y = - 1.20 (95% CI: - 1.80 to -0.30) + 0. 80 (95% CI: 0.55 to 1.00) x for RBC. Conclusions The two analyzers showed similar performances and good compatibility to manual microscopy. However, they are still inadequate in the determination of WBC, RBC, and EC in highly-pathological samples. Thus, confirmation by manual microscopic analysis may be useful. PMID:27812305

  2. Molecularly imprinted polymer microspheres prepared by Pickering emulsion polymerization for selective solid-phase extraction of eight bisphenols from human urine samples.

    PubMed

    Yang, Jiajia; Li, Yun; Wang, Jincheng; Sun, Xiaoli; Cao, Rong; Sun, Hao; Huang, Chaonan; Chen, Jiping

    2015-05-04

    The bisphenol A (BPA) imprinted polymer microspheres were prepared by simple Pickering emulsion polymerization. Compared to traditional bulk polymerization, both high yields of polymer and good control of particle sizes were achieved. The characterization results of scanning electron microscopy and nitrogen adsorption-desorption measurements showed that the obtained molecularly imprinted polymer microsphere (MIPMS) particles possessed regular spherical shape, narrow diameter distribution (30-60 μm), a specific surface area (S(BET)) of 281.26 m(2) g(-1) and a total pore volume (V(t)) of 0.459 cm(3) g(-1). Good specific adsorption capacity for BPA was obtained in the sorption experiment and good class selectivity for BPA and its seven structural analogs (bisphenol F, bisphenol B, bisphenol E, bisphenol AF, bisphenol S, bisphenol AP and bisphenol Z) was demonstrated by the chromatographic evaluation experiment. The MIPMS as solid-phase extraction (SPE) packing material was then evaluated for extraction and clean-up of these bisphenols (BPs) from human urine samples. An accurate and sensitive analytical method based on the MIPMS-SPE coupled with HPLC-DAD has been successfully established for simultaneous determination of eight BPs from human urine samples with detection limits of 1.2-2.2 ng mL(-1). The recoveries of BPs for urine samples at two spiking levels (100 and 500 ng mL(-1) for each BP) were in the range of 81.3-106.7% with RSD values below 8.3%. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. A rapid method for estimation of Pu-isotopes in urine samples using high volume centrifuge.

    PubMed

    Kumar, Ranjeet; Rao, D D; Dubla, Rupali; Yadav, J R

    2017-07-01

    The conventional radio-analytical technique used for estimation of Pu-isotopes in urine samples involves anion exchange/TEVA column separation followed by alpha spectrometry. This sequence of analysis consumes nearly 3-4 days for completion. Many a times excreta analysis results are required urgently, particularly under repeat and incidental/emergency situations. Therefore, there is need to reduce the analysis time for the estimation of Pu-isotopes in bioassay samples. This paper gives the details of standardization of a rapid method for estimation of Pu-isotopes in urine samples using multi-purpose centrifuge, TEVA resin followed by alpha spectrometry. The rapid method involves oxidation of urine samples, co-precipitation of plutonium along with calcium phosphate followed by sample preparation using high volume centrifuge and separation of Pu using TEVA resin. Pu-fraction was electrodeposited and activity estimated using 236 Pu tracer recovery by alpha spectrometry. Ten routine urine samples of radiation workers were analyzed and consistent radiochemical tracer recovery was obtained in the range 47-88% with a mean and standard deviation of 64.4% and 11.3% respectively. With this newly standardized technique, the whole analytical procedure is completed within 9h (one working day hour). Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Arsenic, cadmium, lead, and chromium in well water, rice, and human urine in Sri Lanka in relation to chronic kidney disease of unknown etiology.

    PubMed

    S Herath, H M Ayala; Kawakami, Tomonori; Nagasawa, Shiori; Serikawa, Yuka; Motoyama, Ayuri; Chaminda, G G Tushara; Weragoda, S K; Yatigammana, S K; Amarasooriya, A A G D

    2018-04-01

    Chronic kidney disease of unknown etiology (CKDu) is spreading gradually in Sri Lanka. In the current research, 1,435 well water samples from all 25 districts of Sri Lanka, 91 rice samples, and 84 human urine samples from both CKDu-endemic and non-endemic areas in Sri Lanka were analyzed for arsenic, cadmium, lead, and chromium to detect whether toxic elements could be a cause of CKDu. The liver-type fatty acid binding protein (L-FABP) concentration and arsenic, cadmium, lead, and chromium concentrations of the urine samples were analyzed to determine the relation of L-FABP with arsenic, cadmium, lead, and chromium. High concentrations of arsenic, cadmium, lead, and chromium were not detected in the well water samples from CKDu-endemic areas. Arsenic, cadmium, and lead contents in the rice samples from both CKDu-endemic and non-endemic areas were well below the Codex standard. There were no relationships between the L-FABP concentration and concentrations of arsenic, cadmium, lead, and chromium in urine. In addition, arsenic, cadmium, lead, and chromium concentrations in human urine samples from CKDu-endemic areas were not significantly different from those from non-endemic areas. These findings indicated that arsenic, cadmium, lead, and chromium could not cause CKDu.

  5. Comparison of Sofia Legionella FIA and BinaxNOW® Legionella urinary antigen card in two national reference centers.

    PubMed

    Beraud, L; Gervasoni, K; Freydiere, A M; Descours, G; Ranc, A G; Vandenesch, F; Lina, G; Gaia, V; Jarraud, S

    2015-09-01

    The Sofia Legionella Fluorescence Immunoassay (FIA; Quidel) is a recently introduced rapid immunochromatographic diagnostic test for Legionnaires' disease using immunofluorescence technology designed to enhance its sensitivity. The aim of this study was to evaluate its performance for the detection of urinary antigens for Legionella pneumophila serogroup 1 in two National Reference Centers for Legionella. The sensitivity and specificity of the Sofia Legionella FIA test were determined in concentrated and nonconcentrated urine samples, before and after boiling, in comparison with the BinaxNOW® Legionella Urinary Antigen Card (UAC; Alere). Compared with BinaxNOW® Legionella UAC, the sensitivity of the Sofia Legionella test was slightly higher in nonconcentrated urine samples and was identical in concentrated urine samples. The specificity of the Sofia Legionella FIA test was highly reduced by the concentration of urine samples. In nonconcentrated samples, a lack of specificity was observed in 2.3 % of samples, all of them resolved by heat treatment. The Sofia Legionella FIA is a sensitive test for detecting Legionella urinary antigens with no previous urine concentration. However, all positive samples have to be re-tested after boiling to reach a high specificity. The reading is automatized on the Sofia analyzer, which can be connected to laboratory information systems, facilitating accurate and rapid reporting of results.

  6. The influence of a sports drink on the postexercise metabolism of elite athletes as investigated by NMR-based metabolomics.

    PubMed

    Miccheli, Alfredo; Marini, Federico; Capuani, Giorgio; Miccheli, Alberta Tomassini; Delfini, Maurizio; Di Cocco, Maria Enrica; Puccetti, Caterina; Paci, Maurizio; Rizzo, Marta; Spataro, Antonio

    2009-10-01

    The aim of this study is to evaluate the systemic effects of an isotonic sports drink on the metabolic status of athletes of the Italian Olympic rowing team during recovery after strenuous and prolonged physical exercise by means of nuclear magnetic resonance (NMR)-based metabolomics analysis on plasma and urine. Forty-four male athletes of the Italian Olympic rowing team were enrolled in a double-blind crossover study. All subjects underwent 2 evaluations at 1-week intervals. The evaluation was performed on a rowing ergometer after strenuous physical exercise to produce a state of dehydration. Afterward, the athletes were rehydrated either with a green tea-based carbohydrate-hydroelectrolyte drink or with oligomineral water. Three blood samples were drawn for each subject: at rest, after the exercise, and following rehydratation, while 2 urine samples were collected: at rest and after the rehydratation period. Biofluid samples were analyzed by high-resolution (1)H NMR metabolic profiling combined with multilevel simultaneous data-analysis (MSCA) and partial-least squares-discriminant analysis (PLS-DA). The between-subject variations, as evaluated by MSCA, reflected the variations of lactate levels induced by the physical exercise. Analysis of the within-individual variance using multilevel PLS-DA models of plasma and urine metabolic profiles showed an effect of the green tea-based sports drink on glucose, citrate, and lactate levels in plasma and on acetone, 3-OH-butyrate, and lactate levels in urine. The increase of caffeine and hippuric acid levels in urine indicated the absorption of green tea extract components. NMR-based metabolomics allowed the complex effects of a green tea extract-based carbohydrate/hydroelectrolyte beverage on the energy metabolism of athletes during recovery by postexercise rehydration to be evaluated.

  7. Validation of reliable and selective methods for direct determination of glyphosate and aminomethylphosphonic acid in milk and urine using LC-MS/MS.

    PubMed

    Jensen, Pamela K; Wujcik, Chad E; McGuire, Michelle K; McGuire, Mark A

    2016-01-01

    Simple high-throughput procedures were developed for the direct analysis of glyphosate [N-(phosphonomethyl)glycine] and aminomethylphosphonic acid (AMPA) in human and bovine milk and human urine matrices. Samples were extracted with an acidified aqueous solution on a high-speed shaker. Stable isotope labeled internal standards were added with the extraction solvent to ensure accurate tracking and quantitation. An additional cleanup procedure using partitioning with methylene chloride was required for milk matrices to minimize the presence of matrix components that can impact the longevity of the analytical column. Both analytes were analyzed directly, without derivatization, by liquid chromatography tandem mass spectrometry using two separate precursor-to-product transitions that ensure and confirm the accuracy of the measured results. Method performance was evaluated during validation through a series of assessments that included linearity, accuracy, precision, selectivity, ionization effects and carryover. Limits of quantitation (LOQ) were determined to be 0.1 and 10 µg/L (ppb) for urine and milk, respectively, for both glyphosate and AMPA. Mean recoveries for all matrices were within 89-107% at three separate fortification levels including the LOQ. Precision for replicates was ≤ 7.4% relative standard deviation (RSD) for milk and ≤ 11.4% RSD for urine across all fortification levels. All human and bovine milk samples used for selectivity and ionization effects assessments were free of any detectable levels of glyphosate and AMPA. Some of the human urine samples contained trace levels of glyphosate and AMPA, which were background subtracted for accuracy assessments. Ionization effects testing showed no significant biases from the matrix. A successful independent external validation was conducted using the more complicated milk matrices to demonstrate method transferability.

  8. Simultaneous LC-MS/MS determination of JWH-210, RCS-4, ∆(9)-tetrahydrocannabinol, and their main metabolites in pig and human serum, whole blood, and urine for comparing pharmacokinetic data.

    PubMed

    Schaefer, Nadine; Kettner, Mattias; Laschke, Matthias W; Schlote, Julia; Peters, Benjamin; Bregel, Dietmar; Menger, Michael D; Maurer, Hans H; Ewald, Andreas H; Schmidt, Peter H

    2015-05-01

    A series of new synthetic cannabinoids (SC) has been consumed without any toxicological testing. For example, pharmacokinetic data have to be collected from forensic toxicological case work and/or animal studies. To develop a corresponding model for assessing such data, samples of controlled pig studies with two selected SC (JWH-210, RCS-4) and, as reference, ∆(9)-tetrahydrocannabinol (THC) should be analyzed as well as those of human cases. Therefore, a method for determination of JWH-210, RCS-4, THC, and their main metabolites in pig and human serum, whole blood, and urine samples is presented. Specimens were analyzed by liquid-chromatography tandem mass spectrometry and multiple-reaction monitoring with three transitions per compound. Full validation was carried out for the pig specimens and cross-validation for the human specimens concerning precision and bias. For the pig studies, the limits of detection were between 0.05 and 0.50 ng/mL in serum and whole blood and between 0.05 and 1.0 ng/mL in urine, the lower limits of quantification between 0.25 and 1.0 ng/mL in serum and 0.50 and 2.0 ng/mL in whole blood and urine, and the intra- and interday precision values lower than 15% and bias values within ±15%. The applicability was tested with samples taken from a pharmacokinetic pilot study with pigs following intravenous administration of a mixture of 200 μg/kg body mass dose each of JWH-210, RCS-4, and THC. The cross-validation data for human serum, whole blood, and urine showed that this approach should also be suitable for human specimens, e.g., of clinical or forensic cases.

  9. High-throughput determination of faropenem in human plasma and urine by on-line solid-phase extraction coupled to high-performance liquid chromatography with UV detection and its application to the pharmacokinetic study.

    PubMed

    Xie, Rui; Wen, Jun; Wei, Hua; Fan, Guorong; Zhang, Dabing

    2010-05-01

    An automated system using on-line solid-phase extraction and HPLC with UV detection was developed for the determination of faropenem in human plasma and urine. Analytical process was performed isocratically with two reversed-phase columns connected by a switching valve. After simple pretreatment for plasma and urine with acetonitrile, a volume of 100microl upper layer of the plasma or urine samples was injected for on-line SPE column switching HPLC-UV analysis. The analytes were retained on the self-made trap column (Lichrospher C(18), 4.6mmx37mm, 25microm) with the loading solvent (20mM NaH(2)PO(4) adjusted pH 3.5) at flow rate of 2mlmin(-1), and most matrix materials were removed from the column to waste. After 0.5min washing, the valve was switched to another position so that the target analytes could be eluted from trap column to analytical column in the back-flush mode by the mobile phase (acetonitrile-20mM NaH(2)PO(4) adjusted pH 3.5, 16:84, v/v) at flow rate of 1.5mlmin(-1), and then separated on the analytical column (Ultimate XB-C(18), 4.6mmx50mm, 5microm).The complete cycle of the on-line SPE preconcentration purification and HPLC separation of the analytes was 5min. Calibration curves with good linearities (r=0.9994 for plasma sample and r=0.9988 for urine sample) were obtained in the range 0.02-5microgml(-1) in plasma and 0.05-10microg ml(-1) in urine for faropenem. The optimized method showed good performance in terms of specificity, linearity, detection and quantification limits, precision and accuracy. The method was successfully utilized to quantify faropenem in human plasma and urine to support the clinical pharmacokinetic studies. Copyright 2009 Elsevier B.V. All rights reserved.

  10. Fluoride in drinking water and human urine in Southern Haryana, India.

    PubMed

    Singh, Bhupinder; Gaur, Shalini; Garg, V K

    2007-06-01

    The objective of this study was to determine the fluoride content in drinking water and urine samples of adolescent males aged 11-16 years living in Southern Haryana, India. A total of 30 drinking water sources in the studied habitations were assessed for fluoride contamination. Fluoride was estimated in the urine of 400 male children randomly selected from these habitations. The fluoride concentration in drinking water and urine samples was determined using USEPA fluoride ion selective electrode method. The mean fluoride concentration in drinking water samples of Pataudi, Haily Mandi and Harsaru villages was 1.68+/-0.35, 3.22+/-1.18 and 1.78+/-0.12 mg/l, respectively. The mean urinary fluoride concentration was 2.26+/-0.024 mg/l at Pataudi, 2.48+/-0.77 mg/l at Haily Mandi and 2.43+/-0.84 mg/l at Harsaru village. The higher fluoride levels in the urine of children may be associated to higher fluoride levels in drinking water. The accuracy of measurements was assessed with known addition method in water and urine. Mean fluoride recovery was 98.0 and 99.1% in water and urine. The levels obtained were reproducible with in +/-3% error limit.

  11. [Assessment of dietary intake and urinary excretion of sodium and potassium in adults].

    PubMed

    Cornejo, Karen; Pizarro, Fernando; Atalah, Eduardo; Galgani, José E

    2014-06-01

    Hypertension is associated with elevated sodium and low potassium intakes. The determination of sodium and potassium intake by dietary records is inaccurate, being its measurement from 24-h urine collection the reference method. To determine urinary sodium and potassium excretion in adults. To compare dietary sodium and potassium intake and their excretion from an isolated urine sample against the reference method. Seventy healthy adults aged 35 ± 8 years with a body mass index 25 ± 2 kg/m² (36 women) were studied. Urine was collected over 24 h, including an isolated urine sample taken in fasting conditions. Additionally, three 24-h dietary records were performed. Reported sodium and potassium intake was 2,720 ± 567 and 1,068 ± 433 mg/day, respectively. In turn, urinary excretion of sodium and potassium was 4,770 ± 1,532 and 1,852 ± 559 mg/day, respectively. These latter values were significantly higher than those obtained by dietary records. Furthermore, the urinary sodium and potassium excretion estimated from an isolated urine sample was 4,839 ± 1,355 and 1,845 ± 494 mg/day, respectively. These values were similar to those obtained with a 24 h urine collection. Dietary records underestimated electrolyte intake when compared with the reference method. Using an isolated urine sample to estimate electrolyte intake may be a reliable alternative.

  12. Automatic instrument for chemical processing to detect microorganism in biological samples by measuring light reactions

    NASA Technical Reports Server (NTRS)

    Kelbaugh, B. N.; Picciolo, G. L.; Chappelle, E. W.; Colburn, M. E. (Inventor)

    1973-01-01

    An automated apparatus is reported for sequentially assaying urine samples for the presence of bacterial adenosine triphosphate (ATP) that comprises a rotary table which carries a plurality of sample containing vials and automatically dispenses fluid reagents into the vials preparatory to injecting a light producing luciferase-luciferin mixture into the samples. The device automatically measures the light produced in each urine sample by a bioluminescence reaction of the free bacterial adenosine triphosphate with the luciferase-luciferin mixture. The light measured is proportional to the concentration of bacterial adenosine triphosphate which, in turn, is proportional to the number of bacteria present in the respective urine sample.

  13. Variation of betaine, N,N-dimethylglycine, choline, glycerophosphorylcholine, taurine and trimethylamine-N-oxide in the plasma and urine of overweight people with type 2 diabetes over a two-year period.

    PubMed

    McEntyre, Christopher J; Lever, Michael; Chambers, Stephen T; George, Peter M; Slow, Sandy; Elmslie, Jane L; Florkowski, Christopher M; Lunt, Helen; Krebs, Jeremy D

    2015-05-01

    Plasma betaine concentrations and urinary betaine excretions have high test-retest reliability. Abnormal betaine excretion is common in diabetes. We aimed to confirm the individuality of plasma betaine and urinary betaine excretion in an overweight population with type 2 diabetes and compare this with the individuality of other osmolytes, one-carbon metabolites and trimethylamine-N-oxide (TMAO), thus assessing their potential usefulness as disease markers. Urine and plasma were collected from overweight subjects with type 2 diabetes at four time points over a two-year period. We measured the concentrations of the osmolytes: betaine, glycerophosphorylcholine (GPC) and taurine, as well as TMAO, and the one-carbon metabolites, N,N-dimethylglycine (DMG) and free choline. Samples were measured using tandem mass spectrometry (LC-MS/MS). Betaine showed a high degree of individuality (or test-retest reliability) in the plasma (index of individuality = 0.52) and urine (index of individuality = 0.45). Betaine in the plasma had positive and negative log-normal reference change values (RCVs) of 54% and -35%, respectively. The other osmolytes, taurine and GPC were more variable in the plasma of individuals compared to the urine. DMG and choline showed high individuality in the plasma and urine. TMAO was highly variable in the plasma and urine (log-normal RCVs ranging from 403% to -80% in plasma). Betaine is highly individual in overweight people with diabetes. Betaine, its metabolite DMG, and precursor choline showed more reliability than the osmolytes, GPC and taurine. The low reliability of TMAO suggests that a single TMAO measurement has low diagnostic value. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  14. Ion Chromatography Based Urine Amino Acid Profiling Applied for Diagnosis of Gastric Cancer

    PubMed Central

    Fan, Jing; Hong, Jing; Hu, Jun-Duo; Chen, Jin-Lian

    2012-01-01

    Aim. Amino acid metabolism in cancer patients differs from that in healthy people. In the study, we performed urine-free amino acid profile of gastric cancer at different stages and health subjects to explore potential biomarkers for diagnosing or screening gastric cancer. Methods. Forty three urine samples were collected from inpatients and healthy adults who were divided into 4 groups. Healthy adults were in group A (n = 15), early gastric cancer inpatients in group B (n = 7), and advanced gastric cancer inpatients in group C (n = 16); in addition, two healthy adults and three advanced gastric cancer inpatients were in group D (n = 5) to test models. We performed urine amino acids profile of each group by applying ion chromatography (IC) technique and analyzed urine amino acids according to chromatogram of amino acids standard solution. The data we obtained were processed with statistical analysis. A diagnostic model was constructed to discriminate gastric cancer from healthy individuals and another diagnostic model for clinical staging by principal component analysis. Differentiation performance was validated by the area under the curve (AUC) of receiver-operating characteristic (ROC) curves. Results. The urine-free amino acid profile of gastric cancer patients changed to a certain degree compared with that of healthy adults. Compared with healthy adult group, the levels of valine, isoleucine, and leucine increased (P < 0.05), but the levels of histidine and methionine decreased (P < 0.05), and aspartate decreased significantly (P < 0.01). The urine amino acid profile was also different between early and advanced gastric cancer groups. Compared with early gastric cancer, the levels of isoleucine and valine decreased in advanced gastric cancer (P < 0.05). A diagnosis model constructed for gastric cancer with AUC value of 0.936 tested by group D showed that 4 samples could coincide with it. Another diagnosis model for clinical staging with an AUC value of 0.902 tested by 3 advanced gastric cancer inpatients of group D showed that all could coincide with the model. Conclusions. The noticeable differences of urine-free amino acid profiles between gastric cancer patients and healthy adults indicate that such amino acids as valine, isoleucine, leucine, methionine, histidine and aspartate are important metabolites in cell multiplication and gene expression during tumor growth and metastatic process. The study suggests that urine-free amino acid profiling is of potential value for screening or diagnosing gastric cancer. PMID:22888338

  15. Identification and Validation of Potential New Biomarkers for Prostate Cancer Diagnosis and Prognosis Using 2D-DIGE and MS

    PubMed Central

    Geisler, Cordelia; Gaisa, Nadine T.; Pfister, David; Fuessel, Susanne; Kristiansen, Glen; Braunschweig, Till; Gostek, Sonja; Beine, Birte; Diehl, Hanna C.; Jackson, Angela M.; Borchers, Christoph H.; Heidenreich, Axel; Meyer, Helmut E.; Knüchel, Ruth; Henkel, Corinna

    2015-01-01

    This study was designed to identify and validate potential new biomarkers for prostate cancer and to distinguish patients with and without biochemical relapse. Prostate tissue samples analyzed by 2D-DIGE (two-dimensional difference in gel electrophoresis) and mass spectrometry (MS) revealed downregulation of secernin-1 (P < 0.044) in prostate cancer, while vinculin showed significant upregulation (P < 0.001). Secernin-1 overexpression in prostate tissue was validated using Western blot and immunohistochemistry while vinculin expression was validated using immunohistochemistry. These findings indicate that secernin-1 and vinculin are potential new tissue biomarkers for prostate cancer diagnosis and prognosis, respectively. For validation, protein levels in urine were also examined by Western blot analysis. Urinary vinculin levels in prostate cancer patients were significantly higher than in urine from nontumor patients (P = 0.006). Using multiple reaction monitoring-MS (MRM-MS) analysis, prostatic acid phosphatase (PAP) showed significant higher levels in the urine of prostate cancer patients compared to controls (P = 0.012), while galectin-3 showed significant lower levels in the urine of prostate cancer patients with biochemical relapse, compared to those without relapse (P = 0.017). Three proteins were successfully differentiated between patients with and without prostate cancer and patients with and without relapse by using MRM. Thus, this technique shows promise for implementation as a noninvasive clinical diagnostic technique. PMID:25667921

  16. High performance of a new PCR-based urine assay for HPV-DNA detection and genotyping.

    PubMed

    Tanzi, Elisabetta; Bianchi, Silvia; Fasolo, Maria Michela; Frati, Elena R; Mazza, Francesca; Martinelli, Marianna; Colzani, Daniela; Beretta, Rosangela; Zappa, Alessandra; Orlando, Giovanna

    2013-01-01

    Human papillomavirus (HPV) testing has been proposed as a means of replacing or supporting conventional cervical screening (Pap test). However, both methods require the collection of cervical samples. Urine sample is easier and more acceptable to collect and could be helpful in facilitating cervical cancer screening. The aim of this study was to evaluate the sensitivity and specificity of urine testing compared to conventional cervical smear testing using a PCR-based method with a new, designed specifically primer set. Paired cervical and first voided urine samples collected from 107 women infected with HIV were subjected to HPV-DNA detection and genotyping using a PCR-based assay and a restriction fragment length polymorphism method. Sensitivity, specificity, Positive Predictive Value (PPV), and Negative Predictive Value (NPV) were calculated using the McNemar's test for differences. Concordance between tests was assessed using the Cohen's unweighted Kappa (k). HPV DNA was detected in 64.5% (95% CI: 55.1-73.1%) of both cytobrush and urine samples. High concordance rates of HPV-DNA detection (k = 0.96; 95% CI: 0.90-1.0) and of high risk-clade and low-risk genotyping in paired samples (k = 0.80; 95% CI: 0.67-0.92 and k = 0.74; 95% CI: 0.60-0.88, respectively) were observed. HPV-DNA detection in urine versus cervix testing revealed a sensitivity of 98.6% (95% CI: 93.1-99.9%) and a specificity of 97.4% (95% CI: 87.7-99.9%), with a very high NPV (97.4%; 95% CI: 87.7-99.9%). The PCR-based assay utilized in this study proved highly sensitive and specific for HPV-DNA detection and genotyping in urine samples. These data suggest that a urine-based assay would be a suitable and effective tool for epidemiological surveillance and, most of all, screening programs. Copyright © 2012 Wiley Periodicals, Inc.

  17. Value of Routine Dengue Diagnostic Tests in Urine and Saliva Specimens

    PubMed Central

    Andries, Anne-Claire; Duong, Veasna; Ly, Sowath; Cappelle, Julien; Kim, Kim Srorn; Lorn Try, Patrich; Ros, Sopheaktra; Ong, Sivuth; Huy, Rekol; Horwood, Paul; Flamand, Marie; Sakuntabhai, Anavaj; Tarantola, Arnaud; Buchy, Philippe

    2015-01-01

    Background Dengue laboratory diagnosis is essentially based on detection of the virus, its components or antibodies directed against the virus in blood samples. Blood, however, may be difficult to draw in some patients, especially in children, and sampling during outbreak investigations or epidemiological studies may face logistical challenges or limited compliance to invasive procedures from subjects. The aim of this study was to assess the possibility of using saliva and urine samples instead of blood for dengue diagnosis. Methodology/Principal Findings Serial plasma, urine and saliva samples were collected at several time-points between the day of admission to hospital until three months after the onset of fever in children with confirmed dengue disease. Quantitative RT-PCR, NS1 antigen capture and ELISA serology for anti-DENV antibody (IgG, IgM and IgA) detection were performed in parallel on the three body fluids. RT-PCR and NS1 tests demonstrated an overall sensitivity of 85.4%/63.4%, 41.6%/14.5% and 39%/28.3%, in plasma, urine and saliva specimens, respectively. When urine and saliva samples were collected at the same time-points and tested concurrently, the diagnostic sensitivity of RNA and NS1 detection assays was 69.1% and 34.4%, respectively. IgG/IgA detection assays had an overall sensitivity of 54.4%/37.4%, 38.5%/26.8% and 52.9%/28.6% in plasma, urine and saliva specimens, respectively. IgM were detected in 38.1% and 36% of the plasma and saliva samples but never in urine. Conclusions Although the performances of the different diagnostic methods were not as good in saliva and urine as in plasma specimens, the results obtained by qRT-PCR and by anti-DENV antibody ELISA could well justify the use of these two body fluids to detect dengue infection in situations when the collection of blood specimens is not possible. PMID:26406240

  18. FREEQUNCY OF ESCHERICHIA COLI IN PATIENTS WITH COMMUNITY ACQUIRED URINARY TRACT INFECTION AND THEIR RESISTANCE PATTERN AGAINST SOME COMMONLY USED ANTI BACTERIALS.

    PubMed

    Ahmad, Waseem; Jamshed, Fareeda; Ahmad, Wajeeha

    2015-01-01

    Urinary tract infection (UTI) is a very common health problem and Escherichia coli (E coli) are the most common organisms associated with community acquired UTI. Unfortunately these bacteria have developed extensive resistance against most of the commonly used antibacterials. The objective of this study was to determine the frequency and resistance pattern of E. Coli in patients of community acquired UTI in an area in northern part of Pakistan. Urine specimens were collected from patients who were clinically diagnosed as community acquired UTI. Urine routine examination (Urine RE) was done and samples positive for UTI (Pus cells >10/High Power Field) were included in the study. These samples were inoculated on Eosin Methylene Blue (EMB) agar plates and incubated at 37 degrees C for 36 hours. Suspected colonies were then inoculated further on EMB plates for pure cultures of E. Coli characterized by certain morphological characteristics. IMViC was applied for the confirmation of E coli. In vitro antibiotic susceptibility tests of E. Coli were performed with standardized commercial susceptibility discs (OXOID). Out of 50 specimens, positive for UTI by urine RE, 20 showed pure growth of E. Coli on culture (40%). The majority of the isolates (28%; n=14) were from women while only 12% (n=6) were from men. Escherichia coli showed a high rate of resistance towards Ampicillin (90%), Tetracycline (70%), Erythromycin (70%) and Trimethoprim-Sulfamethoxazole (55%). Sparfloxacin showed better results (45%) than ciprofloxacin (50%). Out of 20 E. Coli isolates, two (10%) were resistant to all the antibacterials except chloramphenicol, eight isolates (40%) showed resistance to six or more than six while 14 (70%) were resistant to four or more than four drugs. Rate of resistance of E. Coli against commonly used antibacterials was quite high and majority of the strains showed multidrug resistance.

  19. Nappy pad urine samples for investigation and treatment of UTI in young children: the 'DUTY' prospective diagnostic cohort study.

    PubMed

    Butler, Christopher C; Sterne, Jonathan Ac; Lawton, Michael; O'Brien, Kathryn; Wootton, Mandy; Hood, Kerenza; Hollingworth, William; Little, Paul; Delaney, Brendan C; van der Voort, Judith; Dudley, Jan; Birnie, Kate; Pickles, Timothy; Waldron, Cherry-Ann; Downing, Harriet; Thomas-Jones, Emma; Lisles, Catherine; Rumsby, Kate; Durbaba, Stevo; Whiting, Penny; Harman, Kim; Howe, Robin; MacGowan, Alasdair; Fletcher, Margaret; Hay, Alastair D

    2016-07-01

    The added diagnostic utility of nappy pad urine samples and the proportion that are contaminated is unknown. To develop a clinical prediction rule for the diagnosis of urinary tract infection (UTI) based on sampling using the nappy pad method. Acutely unwell children <5 years presenting to 233 UK primary care sites. Logistic regression to identify independent associations of symptoms, signs, and urine dipstick test results with UTI; diagnostic utility quantified as area under the receiver operator curves (AUROC). Nappy pad rule characteristics, AUROC, and contamination, compared with findings from clean-catch samples. Nappy pad samples were obtained from 3205 children (82% aged <2 years; 48% female), culture results were available for 2277 (71.0%) and 30 (1.3%) had a UTI on culture. Female sex, smelly urine, darker urine, and the absence of nappy rash were independently associated with a UTI, with an internally-validated, coefficient model AUROC of 0.81 (0.87 for clean-catch), which increased to 0.87 (0.90 for clean-catch) with the addition of dipstick results. GPs' 'working diagnosis' had an AUROC 0.63 (95% confidence intervals [CI] = 0.53 to 0.72). A total of 12.2% of nappy pad and 1.8% of clean-catch samples were 'frankly contaminated' (risk ratio 6.66; 95% CI = 4.95 to 8.96; P<0.001). Nappy pad urine culture results, with features that can be reported by parents and dipstick tests, can be clinically useful, but are less accurate and more often contaminated compared with clean-catch urine culture. © British Journal of General Practice 2016.

  20. Nappy pad urine samples for investigation and treatment of UTI in young children: the ‘DUTY’ prospective diagnostic cohort study

    PubMed Central

    Butler, Christopher C; Sterne, Jonathan AC; Lawton, Michael; O’Brien, Kathryn; Wootton, Mandy; Hood, Kerenza; Hollingworth, William; Little, Paul; Delaney, Brendan C; van der Voort, Judith; Dudley, Jan; Birnie, Kate; Pickles, Timothy; Waldron, Cherry-Ann; Downing, Harriet; Thomas-Jones, Emma; Lisles, Catherine; Rumsby, Kate; Durbaba, Stevo; Whiting, Penny; Harman, Kim; Howe, Robin; MacGowan, Alasdair; Fletcher, Margaret; Hay, Alastair D

    2016-01-01

    Background The added diagnostic utility of nappy pad urine samples and the proportion that are contaminated is unknown. Aim To develop a clinical prediction rule for the diagnosis of urinary tract infection (UTI) based on sampling using the nappy pad method. Design and setting Acutely unwell children <5 years presenting to 233 UK primary care sites. Method Logistic regression to identify independent associations of symptoms, signs, and urine dipstick test results with UTI; diagnostic utility quantified as area under the receiver operator curves (AUROC). Nappy pad rule characteristics, AUROC, and contamination, compared with findings from clean-catch samples. Results Nappy pad samples were obtained from 3205 children (82% aged <2 years; 48% female), culture results were available for 2277 (71.0%) and 30 (1.3%) had a UTI on culture. Female sex, smelly urine, darker urine, and the absence of nappy rash were independently associated with a UTI, with an internally-validated, coefficient model AUROC of 0.81 (0.87 for clean-catch), which increased to 0.87 (0.90 for clean-catch) with the addition of dipstick results. GPs’ ‘working diagnosis’ had an AUROC 0.63 (95% confidence intervals [CI] = 0.53 to 0.72). A total of 12.2% of nappy pad and 1.8% of clean-catch samples were ‘frankly contaminated’ (risk ratio 6.66; 95% CI = 4.95 to 8.96; P<0.001). Conclusion Nappy pad urine culture results, with features that can be reported by parents and dipstick tests, can be clinically useful, but are less accurate and more often contaminated compared with clean-catch urine culture. PMID:27364678

  1. A population study of urine glycerol concentrations in elite athletes competing in North America.

    PubMed

    Kelly, Brian N; Madsen, Myke; Sharpe, Ken; Nair, Vinod; Eichner, Daniel

    2013-01-01

    Glycerol is an endogenous substance that is on the World Anti-Doping Agency's list of prohibited threshold substances due to its potential use as a plasma volume expansion agent. The WADA has set the threshold for urine glycerol, including measurement uncertainty, at 1.3 mg/mL. Glycerol in circulation largely comes from metabolism of triglycerides in order to meet energy requirements and when the renal threshold is eclipsed, glycerol is excreted into urine. In part due to ethnic differences in postprandial triglyceride concentrations, we investigated urine glycerol concentrations in a population of elite athletes competing in North America and compared the results to those of athletes competing in Europe. 959 urine samples from elite athletes competing in North America collected for anti-doping purposes were analyzed for urine glycerol concentrations by a gas chromatography mass-spectrometry method. Samples were divided into groups according to: Timing (in- or out-of-competition), Class (strength, game, or endurance sports) and Gender. 333 (34.7%) samples had undetectable amounts of glycerol (<1 μg/mL). 861 (89.8%) of the samples had glycerol concentrations ≤20 μg/mL. The highest glycerol concentration observed was 652 μg/mL. Analysis of the data finds the effects of each category to be statistically significant. The largest estimate of the 99.9(th) percentile, from the in-competition, female, strength athlete samples, was 1813 μg/mL with a 95% confidence range from 774 to 4251 μg/mL. This suggests a conservative threshold of 4.3 mg/mL, which would result in a reasonable detection window for urine samples collected in-competition for all genders and sport classes. Copyright © 2013 John Wiley & Sons, Ltd.

  2. Rapid determination of 226Ra in emergency urine samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxwell, Sherrod L.; Culligan, Brian K.; Hutchison, Jay B.

    2014-02-27

    A new method has been developed at the Savannah River National Laboratory (SRNL) that can be used for the rapid determination of 226Ra in emergency urine samples following a radiological incident. If a radiological dispersive device event or a nuclear accident occurs, there will be an urgent need for rapid analyses of radionuclides in urine samples to ensure the safety of the public. Large numbers of urine samples will have to be analyzed very quickly. This new SRNL method was applied to 100 mL urine aliquots, however this method can be applied to smaller or larger sample aliquots as needed.more » The method was optimized for rapid turnaround times; urine samples may be prepared for counting in <3 h. A rapid calcium phosphate precipitation method was used to pre-concentrate 226Ra from the urine sample matrix, followed by removal of calcium by cation exchange separation. A stacked elution method using DGA Resin was used to purify the 226Ra during the cation exchange elution step. This approach combines the cation resin elution step with the simultaneous purification of 226Ra with DGA Resin, saving time. 133Ba was used instead of 225Ra as tracer to allow immediate counting; however, 225Ra can still be used as an option. The rapid purification of 226Ra to remove interferences using DGA Resin was compared with a slightly longer Ln Resin approach. A final barium sulfate micro-precipitation step was used with isopropanol present to reduce solubility; producing alpha spectrometry sources with peaks typically <40 keV FWHM (full width half max). This new rapid method is fast, has very high tracer yield (>90 %), and removes interferences effectively. The sample preparation method can also be adapted to ICP-MS measurement of 226Ra, with rapid removal of isobaric interferences.« less

  3. Longitudinal Urinary Protein Variability in Participants of the Space Flight Simulation Program.

    PubMed

    Khristenko, Nina A; Larina, Irina M; Domon, Bruno

    2016-01-04

    Urine is a valuable material for the diagnosis of renal pathologies and to investigate the effects of their treatment. However, the variability in protein abundance in the context of normal homeostasis remains a major challenge in urinary proteomics. In this study, the analysis of urine samples collected from healthy individuals, rigorously selected to take part in the MARS-500 spaceflight simulation program, provided a unique opportunity to estimate normal concentration ranges for an extended set of urinary proteins. In order to systematically identify and reliably quantify peptides/proteins across a large sample cohort, a targeted mass spectrometry method was developed. The performance of parallel reaction monitoring (PRM) analyses was improved by implementing tight control of the monitoring windows during LC-MS/MS runs, using an on-the-fly correction routine. Matching the experimentally obtained MS/MS spectra with reference fragmentation patterns allowed dependable peptide identifications to be made. Following optimization and evaluation, the targeted method was applied to investigate protein abundance variability in 56 urine samples, collected from six volunteers participating in the MARS-500 program. The intrapersonal protein concentration ranges were determined for each individual and showed unexpectedly high abundance variation, with an average difference of 1 order of magnitude.

  4. [Validity of the assessment of urinary protein excretion by spot urine in patients with chronic kidney disease].

    PubMed

    Hayashi, Ami; Okada, Tomonari; Matsumoto, Hiroshi; Nagaoka, Yume; Wada, Toshikazu; Gondo, Asako; Nango, Tomoka; Miyaoka, Yoshitaka; Watanabe, Kanna; Iwata, Azusa; Nakao, Toshiyuki

    2013-01-01

    We investigate the validity of the assessment of urinary protein excretion by spot urine samples collected by different methods in outpatients with chronic kidney disease (CKD). SUBJECTS AND METHODS We obtained 24-hour urine and two spot urine samples, including the first morning urine and daytime urine in 159 CKD patients. Urinary protein excretion was assessed by the protein/creatinine ratio from spot urine samples (morning: m-UP (g/gCr), daytime: d-UP (g/gCr) ]. We examined the correlations and the differences among m-UP, d-UP and the actual urinary protein excretion obtained by 24-hour urine (a-UP(g/day) . Significant correlations were found between m-UP and a-UP, and between d-UP and a-UP (r = 0.88, 0.85; p < 0.001). Correlations between m-UP and a-UP were greater relative to those between d-UP and a-UP in patients with less than 3.5 g/day of a-UP and in patients with CKD stages 1 to approximately 3. The percent difference between m-UP and a-UP was--16.0 +/- 40.5%, and that between d-UP and a-UP was 27.1 +/- 72.9%. The absolute value of the percent difference between d-UP and a-UP tended to be greater than that between m-UP and a-UP (34.9 +/- 25.9% vs. 49.9 +/- 59.9%, p = 0.06). Urinary protein/creatinie ratio of the first morning urine is better approximate the urinary protein excretion obtained by 24-hour urine compared with that of spot urine in the daytime.

  5. DEVELOPMENT AND EVALUATION OF AN ENZYME-LINKED IMMUNOASSAY (ELISA) METHOD FOR THE MEASUREMENT OF 2,4-DICHLOROPHENOXYACETIC ACID IN HUMAN URINE

    EPA Science Inventory

    This paper describes the development of a 96-microwell high sample capacity ELISA method for measuring 2,4-D in urine; the analysis of 2,4-D in real-world urine samples by both ELISA and GC/MS methods; and compares the ELISA and GC/MS results in several key areas: accuracy, preci...

  6. Optimization for Peptide Sample Preparation for Urine Peptidomics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sigdel, Tara K.; Nicora, Carrie D.; Hsieh, Szu-Chuan

    2014-02-25

    Analysis of native or endogenous peptides in biofluids can provide valuable insights into disease mechanisms. Furthermore, the detected peptides may also have utility as potential biomarkers for non-invasive monitoring of human diseases. The non-invasive nature of urine collection and the abundance of peptides in the urine makes analysis by high-throughput ‘peptidomics’ methods , an attractive approach for investigating the pathogenesis of renal disease. However, urine peptidomics methodologies can be problematic with regards to difficulties associated with sample preparation. The urine matrix can provide significant background interference in making the analytical measurements that it hampers both the identification of peptides andmore » the depth of the peptidomics read when utilizing LC-MS based peptidome analysis. We report on a novel adaptation of the standard solid phase extraction (SPE) method to a modified SPE (mSPE) approach for improved peptide yield and analysis sensitivity with LC-MS based peptidomics in terms of time, cost, clogging of the LC-MS column, peptide yield, peptide quality, and number of peptides identified by each method. Expense and time requirements were comparable for both SPE and mSPE, but more interfering contaminants from the urine matrix were evident in the SPE preparations (e.g., clogging of the LC-MS columns, yellowish background coloration of prepared samples due to retained urobilin, lower peptide yields) when compared to the mSPE method. When we compared data from technical replicates of 4 runs, the mSPE method provided significantly improved efficiencies for the preparation of samples from urine (e.g., mSPE peptide identification 82% versus 18% with SPE; p = 8.92E-05). Additionally, peptide identifications, when applying the mSPE method, highlighted the biology of differential activation of urine peptidases during acute renal transplant rejection with distinct laddering of specific peptides, which was obscured for most proteins when utilizing the conventional SPE method. In conclusion, the mSPE method was found to be superior to the conventional, standard SPE method for urine peptide sample preparation when applying LC-MS peptidomics analysis due to the optimized sample clean up that provided improved experimental inference from the confidently identified peptides.« less

  7. [The BK virus load in urine in association with the development of hemorrhagic cystitis after hematopoietic stem cell transplantation].

    PubMed

    Xie, Ying; Han, Yue; Wu, De-pei; Sun, Ai-ning; Cen, Jian-nong; Yao, Li; Ruan, Chang-geng

    2009-08-01

    To analyze the relationship between BK viruria and the late onset hemorrhagic cystitis (LOHC) after hematopoietic stem cell transplantation (HSCT), and investigate the role of BK virus load in the development of LOHC. From August 2006 to April 2008, urine samples were collected weekly from 113 patients undergoing HSCT. Virus DNA were extracted from the urine samples and amplified by qualitative PCR. Real-time quantitative PCR was used to quantify BKV DNA in the urine samples of all BK viruria patients. LOHC occurred in 22 patients (19.5%), including grade 1 in 7, grade 2 in 11, grade 3 in 3, and grade 4 in one. The median onset time was 44 (13 - 114) days after transplantation. Twenty-one of which (95.5%) were BK virus positive, being significantly higher than that in non-LOHC patients (31.9%) (P = 0.000). No BK virus was detected in the healthy control group at the same time. Quantitative PCR detection showed that the mean BK virus DNA copies in LOHC patients at a week before occurring HC was higher than that at the first positive samples (10(5) copies/microl versus 10(4) copies/microl, P = 0.025), and it was no significant change at the onset and a week after HC. Meanwhile, there was no statistical difference in the mean level of BK virus DNA copies among the LOHC patients with different grades. The mean level of BK virus DNA copies in non-HC patients was 10(3) to 10(4) copies/microl, being lower than that in LOHC patients. BK viruria is an important pathogenic cause of the LOHC after HSCT. The occurrence of BKV viruria in HSCT patients, together with the increasing of BK virus DNA copies in urine, over the level of 10(5) copies/microl may indicate a possible development of LOHC.

  8. Determination of oxycodone and its major metabolites noroxycodone and oxymorphone by ultra-high-performance liquid chromatography tandem mass spectrometry in plasma and urine: application to real cases.

    PubMed

    Pantano, Flaminia; Brauneis, Stefano; Forneris, Alexandre; Pacifici, Roberta; Marinelli, Enrico; Kyriakou, Chrystalla; Pichini, Simona; Busardò, Francesco Paolo

    2017-08-28

    Oxycodone is a narcotic drug widely used to alleviate moderate and severe acute and chronic pain. Variability in analgesic efficacy could be explained by inter-subject variations in plasma concentrations of parent drug and its active metabolite, oxymorphone. To evaluate patient compliance and to set up therapeutic drug monitoring (TDM), an ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) assay was developed and validated for the parent drug and its major metabolites noroxycodone and oxymorphone. Extraction of analytes from plasma and urine samples was obtained by simple liquid-liquid extraction. The chromatographic separation was achieved with a reversed phase column using a linear gradient elution with two solvents: acetic acid 1% in water and methanol. The separated analytes were detected with a triple quadrupole mass spectrometer operated in multiple reaction monitoring (MRM) mode via positive electrospray ionization (ESI). Separation of analytes was obtained in less than 5 min. Linear calibration curves for all the analytes under investigation in urine and plasma samples showed determination coefficients (r2) equal or higher than 0.990. Mean absolute analytical recoveries were always above 86%. Intra- and inter-assay precision (measured as coefficient of variation, CV%) and accuracy (measured as % error) values were always better than 13%. Limit of detection at 0.06 and 0.15 ng/mL and limit of quantification at 0.2 and 0.5 ng/mL for plasma and urine samples, respectively, were adequate for the purpose of the present study. Rapid extraction, identification and quantification of oxycodone and its metabolites both in urine and plasma by UHPLC-MS/MS assay was tested for its feasibility in clinical samples and provided excellent results for rapid and effective drug testing in patients under oxycodone treatment.

  9. A dilute-and-shoot flow-injection tandem mass spectrometry method for quantification of phenobarbital in urine.

    PubMed

    Alagandula, Ravali; Zhou, Xiang; Guo, Baochuan

    2017-01-15

    Liquid chromatography/tandem mass spectrometry (LC/MS/MS) is the gold standard of urine drug testing. However, current LC-based methods are time consuming, limiting the throughput of MS-based testing and increasing the cost. This is particularly problematic for quantification of drugs such as phenobarbital, which is often analyzed in a separate run because they must be negatively ionized. This study examined the feasibility of using a dilute-and-shoot flow-injection method without LC separation to quantify drugs with phenobarbital as a model system. Briefly, a urine sample containing phenobarbital was first diluted by 10 times, followed by flow injection of the diluted sample to mass spectrometer. Quantification and detection of phenobarbital were achieved by an electrospray negative ionization MS/MS system operated in the multiple reaction monitoring (MRM) mode with the stable-isotope-labeled drug as internal standard. The dilute-and-shoot flow-injection method developed was linear with a dynamic range of 50-2000 ng/mL of phenobarbital and correlation coefficient > 0.9996. The coefficients of variation and relative errors for intra- and inter-assays at four quality control (QC) levels (50, 125, 445 and 1600 ng/mL) were 3.0% and 5.0%, respectively. The total run time to quantify one sample was 2 min, and the sensitivity and specificity of the method did not deteriorate even after 1200 consecutive injections. Our method can accurately and robustly quantify phenobarbital in urine without LC separation. Because of its 2 min run time, the method can process 720 samples per day. This feasibility study shows that the dilute-and-shoot flow-injection method can be a general way for fast analysis of drugs in urine. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  10. Dosage effect on uropathogenic Escherichia coli anti-adhesion activity in urine following consumption of cranberry powder standardized for proanthocyanidin content: a multicentric randomized double blind study

    PubMed Central

    2010-01-01

    Background Ingestion of cranberry (Vaccinium macrocarpon Ait.) has traditionally been utilized for prevention of urinary tract infections. The proanthocyanidins (PACs) in cranberry, in particular the A-type linkages have been implicated as important inhibitors of primarily P-fimbriated E. coli adhesion to uroepithelial cells. Additional experiments were required to investigate the persistence in urine samples over a broader time period, to determine the most effective dose per day and to determine if the urinary anti-adhesion effect following cranberry is detected within volunteers of different origins. Methods Two separate bioassays (a mannose-resistant hemagglutination assay and an original new human T24 epithelial cell-line assay) have assessed the ex-vivo urinary bacterial anti-adhesion activity on urines samples collected from 32 volunteers from Japan, Hungary, Spain and France in a randomized, double-blind versus placebo study. An in vivo Caenorhabditis elegans model was used to evaluate the influence of cranberry regimen on the virulence of E. coli strain. Results The results indicated a significant bacterial anti-adhesion activity in urine samples collected from volunteers that consumed cranberry powder compared to placebo (p < 0.001). This inhibition was clearly dose-dependent, prolonged (until 24 h with 72 mg of PAC) and increasing with the amount of PAC equivalents consumed in each cranberry powder regimen. An in vivo Caenorhabditis elegans model showed that cranberry acted against bacterial virulence: E. coli strain presented a reduced ability to kill worms after a growth in urines samples of patients who took cranberry capsules. This effect is particularly important with the regimen of 72 mg of PAC. Conclusions Administration of PAC-standardized cranberry powder at dosages containing 72 mg of PAC per day may offer some protection against bacterial adhesion and virulence in the urinary tract. This effect may offer a nyctohemeral protection. PMID:20398248

  11. Cannabis Use Surveillance by Sweat Analysis.

    PubMed

    Gambelunghe, Cristiana; Fucci, Nadia; Aroni, Kyriaki; Bacci, Mauro; Marcelli, Antonio; Rossi, Riccardo

    2016-10-01

    Sweat testing, an alternative matrix for establishing drug abuse, offers additional benefits to the more common biological samples. The authors developed a procedure using gas chromatography-mass spectrometry to test for Δ9-tetrahydrocannabinol, 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid, cannabinol (CBN), and cannabidiol (CBD) in a sweat patch. The results were compared with urine and hair sample results. Urine, hair, and sweat samples were simultaneously collected from 12 patients who were involved, respectively, in forensic case and monitoring abuse. Selectivity, linearity, limit of detection (LOD), limit of quantification (LOQ), recovery, intraday and interday imprecision, and inaccuracy of the quantification procedure were validated. LODs in hair were 0.05 ng/mg for Δ9-tetrahydrocannabinol, CBN, and CBD, and 0.005 ng/mg for 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid. The LOD for sweat was 0.30 ng/patch for all substances. The LOQ in hair was 0.1 ng/mg for Δ9-tetrahydrocannabinol, CBN, and CBD, and 0.01 ng/mg for 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid. The LOQ was 0.4 ng/patch in sweat for each analyte. Cannabinoid in urine was determined by means of immunochemical screening (cutoff 11-nor-Δ-tetrahydrocannabinol-9-carboxylic acid 50 ng/mL). All subjects tested positive for 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid and Δ9-tetrahydrocannabinol in urine and hair. In sweat samples, Δ9-tetrahydrocannabinol was found in all patches (0.4-2.0 ng/patch); 6 cases were positive for CBN (0.4-0.5 ng/patch) and 3 for CBD (0.4-0.6 ng/patch); 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid was never detected in patches. Present sweat analysis results integrated the information from hair and urine and showed that sweat analysis is a suitable, noninvasive method for monitoring compliance with rehabilitation therapy and for detecting recent cumulative use of cannabinoids.

  12. Fabric phase sorptive extraction-high performance liquid chromatography-photo diode array detection method for simultaneous monitoring of three inflammatory bowel disease treatment drugs in whole blood, plasma and urine.

    PubMed

    Kabir, Abuzar; Furton, Kenneth G; Tinari, Nicola; Grossi, Laurino; Innosa, Denise; Macerola, Daniela; Tartaglia, Angela; Di Donato, Valentina; D'Ovidio, Cristian; Locatelli, Marcello

    2018-05-01

    This paper reports a novel fabric phase sorptive extraction-high performance liquid chromatography-photodiode array detection (FPSE-HPLC-PDA) method for the simultaneous extraction and analysis of three drug residues (ciprofloxacin, sulfasalazine, and cortisone) in human whole blood, plasma, and urine samples, generally administered in human patients to treat inflammatory bowel disease (IBD). The drugs of interest were well resolved using a Luna C 18 column (250 mm × 4.6 mm; 5 μm particle size) in gradient elution mode within 20 min. The analytical method was optimized and validated in the range 0.05-10 μg/mL for whole blood, 0.25-10 μg/mL for human plasma, and 0.10-10 μg/mL for human urine. Blank human whole blood, plasma, and urine were used as the sample matrix for the method development and validation; while methyl-p-hydroxybenzoate was used as the internal standard (IS). Weighted-matrix matched standard calibration curves showed a good linearity up to a concentration of 10 μg/mL. The intra- and inter-day accuracy values (precision and trueness) were found in the range from -10.9% to 12.3%, and the performances of the validated FPSE-HPLC-PDA were further tested on real IBD patient samples. This is the first FPSE procedure applied simultaneously to whole blood, plasma, and urine samples for the determination of residual IBD drugs, which possess a wide range of polarity (logP values ranging from 2.30 for Ciprofloxacin, to 1.66 for Cortisone, and 2.92 for Sulfasalazine). The new approach exhibits high potential for immediate adoptation as a rapid, robust and green analytical tool for future clinical and pharmaceutical applications. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Urinary 1-Hydroxypyrene as a Biomarker to Carcinogenic Polycyclic Aromatic Hydrocarbon Exposure

    PubMed Central

    Ifegwu, Clinton; Osunjaye, Kayode; Fashogbon, Folasade; Oke, Kolawole; Adeniyi, Afolabi; Anyakora, Chimezie

    2012-01-01

    In order to capture the extent of exposure to polycyclic aromatic hydrocarbons (PAHs), various biomarkers have been employed. The biomarkers employed for PAHs include PAHs genetoxic end points in lymphocytes, urinary metabolites, PAH-DNA adducts, and PAH-Protein adducts. Of these, excretory 1-hydroxypyene, a metabolite of pyrene, has been used extensively as a biological monitoring indicator of exposure to PAHs. This study attempts to assess the level of this biomarker in the body fluid of 68 exposed subjects using high performance liquid chromatography HPLC. The subjects screened included auto mechanics, drivers, and fuel attendants. 1-hydroxypyrene was extracted from the urine of the subjects using solid phase extraction method. The HPLC analysis was done in isocratic mode using water:methanol (12:88 v/v) mobile phase. The stationary phase was XBridge C18 (150 × 4.6 mm) 5 μm column. The wavelength was 250 nm at a flow rate of 1.2 mL/min. The oven temperature was 30 ºC and the injection volume was 20 μL. The run time was 3 minutes. The level of urinary 1-hydroxypyrene detected varied for the different categories of occupation studied. About 27% of sampled fuel attendants and 22% of auto mechanics had detectable 1-hydroxypyrene in their urine samples. There was no detectable 1-hydroxypyene in the urine samples of commercial drivers or in the urine samples of students used as controls. The results of this study showed that fuel attendants and auto mechanics have significant exposures to PAHs. So far, there is no established benchmark for level of PAHs in urine, but our findings indicate the possibility of future cancer cases in this population as a result of their occupational exposure. The study was not able to link the level of 1-hydroxypyene with the smoking habits of the subjects. PMID:24179391

  14. Urinary 1-hydroxypyrene as a biomarker to carcinogenic polycyclic aromatic hydrocarbon exposure.

    PubMed

    Ifegwu, Clinton; Osunjaye, Kayode; Fashogbon, Folasade; Oke, Kolawole; Adeniyi, Afolabi; Anyakora, Chimezie

    2012-01-01

    In order to capture the extent of exposure to polycyclic aromatic hydrocarbons (PAHs), various biomarkers have been employed. The biomarkers employed for PAHs include PAHs genetoxic end points in lymphocytes, urinary metabolites, PAH-DNA adducts, and PAH-Protein adducts. Of these, excretory 1-hydroxypyene, a metabolite of pyrene, has been used extensively as a biological monitoring indicator of exposure to PAHs. This study attempts to assess the level of this biomarker in the body fluid of 68 exposed subjects using high performance liquid chromatography HPLC. The subjects screened included auto mechanics, drivers, and fuel attendants. 1-hydroxypyrene was extracted from the urine of the subjects using solid phase extraction method. The HPLC analysis was done in isocratic mode using water:methanol (12:88 v/v) mobile phase. The stationary phase was XBridge C18 (150 × 4.6 mm) 5 μm column. The wavelength was 250 nm at a flow rate of 1.2 mL/min. The oven temperature was 30 ºC and the injection volume was 20 μL. The run time was 3 minutes. The level of urinary 1-hydroxypyrene detected varied for the different categories of occupation studied. About 27% of sampled fuel attendants and 22% of auto mechanics had detectable 1-hydroxypyrene in their urine samples. There was no detectable 1-hydroxypyene in the urine samples of commercial drivers or in the urine samples of students used as controls. The results of this study showed that fuel attendants and auto mechanics have significant exposures to PAHs. So far, there is no established benchmark for level of PAHs in urine, but our findings indicate the possibility of future cancer cases in this population as a result of their occupational exposure. The study was not able to link the level of 1-hydroxypyene with the smoking habits of the subjects.

  15. Hollow-fiber-supported liquid phase microextraction with in situ derivatization and gas chromatography-mass spectrometry for determination of chlorophenols in human urine samples.

    PubMed

    Ito, Rie; Kawaguchi, Migaku; Honda, Hidehiro; Koganei, Youji; Okanouchi, Noriya; Sakui, Norihiro; Saito, Koichi; Nakazawa, Hiroyuki

    2008-09-01

    A simple and highly sensitive method that involves hollow-fiber-supported liquid phase microextraction (HF-LPME) with in situ derivatization and gas chromatography-mass spectrometry (GC-MS) was developed for the determination of chlorophenols (CPs) such as 2,4-dichlorophenol (DCP), 2,4,6-trichlorophenol (TrCP), 2,3,4,6-tetrachlorophenol (TeCP) and pentachlorophenol (PCP) in human urine samples. Human urine samples were enzymatically de-conjugated with beta-glucuronidase and sulfatase. After de-conjugation, HF-LPME with in situ derivatization was performed. After extraction, 2 microl of extract was carefully withdrawn into a syringe and injected into the GC-MS system. The limits of detection (S/N=3) and quantification (S/N>10) of CPs in the human urine samples are 0.1-0.2 ng ml(-1) and 0.5-1 ng ml(-1), respectively. The calibration curve for CPs is linear with a correlation coefficient of >0.99 in the range of 0.5-500 ng ml(-1) for DCP and TrCP, and of 1-500 ng ml(-1) for TeCP and PCP, respectively. The average recoveries of CPs (n=6) in human urine samples are 81.0-104.0% (R.S.D.: 1.9-6.6%) with correction using added surrogate standards. When the proposed method was applied to human urine samples, CPs were detected at sub-ng ml(-1) level.

  16. Simultaneous immunostaining with anti-S100P and anti-SV40 antibodies revealed the origin of BK virus-infected decoy cells in voided urine samples.

    PubMed

    Ariyasu, S; Yanai, H; Sato, M; Shinno, Y; Taniguchi, K; Yamadori, I; Miki, Y; Sato, Y; Yoshino, T; Takahashi, K

    2015-08-01

    Methods for determining the origin of BK virus (BKV)-infected cells (decoy cells) in clinical urine samples have not been established although they could enhance the diagnosis of BKV infection in immunocompromised patients. We performed simultaneous immunostaining with anti-S100P (a urothelial marker) and anti-SV40 antibodies in 66 clinical urine samples exhibiting SV40 positivity and a decoy-cell appearance on Papanicolaou staining. The clinical voided urine samples included seven cases of renal transplantation, 47 cases of cancer therapy and 12 cases of non-neoplastic disease. SurePath(™) liquid-based cytology was used for the urine samples. BKV-infected cells were categorized as SV40(+)/S100P(+) and SV40 (+)/S100p(-). SV40(+)/S100P(-) cells were found in 55 cases (83.4%); nine cases (13.6%) carried both SV40(+)/S100P(-) and SV40(+)/S100P(+) cells. The former were identified as BKV infection in renal tubules and the latter in both the renal tubules and urothelial epithelia. The remaining two cases (3.0%) had only SV40(+)/S100P(+) cells of urothelial origin. Simultaneous immunostaining with anti-S100P and anti-SV40 is a useful method for determining the origin of BKV-infected cells in clinical urine samples from immunocompromised patients such as renal transplantation recipients. © 2014 John Wiley & Sons Ltd.

  17. Water-loss (intracellular) dehydration assessed using urinary tests: how well do they work? Diagnostic accuracy in older people.

    PubMed

    Hooper, Lee; Bunn, Diane K; Abdelhamid, Asmaa; Gillings, Rachel; Jennings, Amy; Maas, Katie; Millar, Sophie; Twomlow, Elizabeth; Hunter, Paul R; Shepstone, Lee; Potter, John F; Fairweather-Tait, Susan J

    2016-07-01

    Water-loss dehydration (hypertonic, hyperosmotic, or intracellular dehydration) is due to insufficient fluid intake and is distinct from hypovolemia due to excess fluid losses. Water-loss dehydration is associated with poor health outcomes such as disability and mortality in older people. Urine specific gravity (USG), urine color, and urine osmolality have been widely advocated for screening for dehydration in older adults. We assessed the diagnostic accuracy of urinary measures to screen for water-loss dehydration in older people. This was a diagnostic accuracy study of people aged ≥65 y taking part in the DRIE (Dehydration Recognition In our Elders; living in long-term care) or NU-AGE (Dietary Strategies for Healthy Ageing in Europe; living in the community) studies. The reference standard was serum osmolality, and index tests included USG, urine color, urine osmolality, urine cloudiness, additional dipstick measures, ability to provide a urine sample, and the volume of a random urine sample. Minimum useful diagnostic accuracy was set at sensitivity and specificity ≥70% or a receiver operating characteristic plot area under the curve ≥0.70. DRIE participants (women: 67%; mean age: 86 y; n = 162) had more limited cognitive and functional abilities than did NU-AGE participants (women: 64%; mean age: 70 y; n = 151). Nineteen percent of DRIE participants and 22% of NU-AGE participants were dehydrated (serum osmolality >300 mOsm/kg). Neither USG nor any other potential urinary tests were usefully diagnostic for water-loss dehydration. Although USG, urine color, and urinary osmolality have been widely advocated for screening for dehydration in older adults, we show, in the largest study to date to our knowledge, that their diagnostic accuracy is too low to be useful, and these measures should not be used to indicate hydration status in older people (either alone or as part of a wider tranche of tests). There is a need to develop simple, inexpensive, and noninvasive tools for the assessment of dehydration in older people. The DRIE study was registered at www.researchregister.org.uk as 122273. The NU-AGE trial was registered at clinicialtrials.gov as NCT01754012. © 2016 American Society for Nutrition.

  18. Validation of a urine color scale for assessment of urine osmolality in healthy children.

    PubMed

    Kavouras, Stavros A; Johnson, Evan C; Bougatsas, Dimitris; Arnaoutis, Giannis; Panagiotakos, Demosthenes B; Perrier, Erica; Klein, Alexis

    2016-04-01

    Urine color (UC) is a practical tool for hydration assessment. The technique has been validated in adults, but has not been tested in children. The purpose of the study was to test the validity of the urine color scale in young, healthy boys and girls, as a marker of urine concentration, investigate its diagnostic ability of detecting hypohydration and examine the ability of children to self-assess UC. A total of 210 children participated (age: 8-14 years, body mass: 43.4 ± 12.6 kg, height: 1.49 ± 0.13 m, body fat: 25.2 ± 7.8 %). Data collection included: two single urine samples (first morning and before lunch) and 24-h sampling. Hydration status was assessed via urine osmolality (UOsmo) and UC via the eight-point color scale. Mean UC was 3 ± 1 and UOsmo 686 ± 223 mmol kg(-1). UC displayed a positive relationship as a predictor of UOsmo (R (2): 0.45, P < 0.001). Based on the receiver operating curve, UC has good overall classification ability for the three samples (area under the curve 85-92 %), with good sensitivity (92-98 %) and specificity (55-68 %) for detecting hypohydration. The overall accuracy of the self-assessment of UC in the morning or the noon samples ranged from 67 to 78 %. Further threshold analysis indicated that the optimal self-assessed UC threshold for hypohydration was ≥4. The classical eight-point urine color scale is a valid method to assess hydration in children of age 8-14 years, either by researchers or self-assessment.

  19. Analysis of the variability of human normal urine by 2D-GE reveals a "public" and a "private" proteome.

    PubMed

    Molina, Laurence; Salvetat, Nicolas; Ameur, Randa Ben; Peres, Sabine; Sommerer, Nicolas; Jarraya, Fayçal; Ayadi, Hammadi; Molina, Franck; Granier, Claude

    2011-12-10

    The characterization of the normal urinary proteome is steadily progressing and represents a major interest in the assessment of clinical urinary biomarkers. To estimate quantitatively the variability of the normal urinary proteome, urines of 20 healthy people were collected. We first evaluated the impact of the sample conservation temperature on urine proteome integrity. Keeping the urine sample at RT or at +4°C until storage at -80°C seems the best way for long-term storage of samples for 2D-GE analysis. The quantitative variability of the normal urinary proteome was estimated on the 20 urines mapped by 2D-GE. The occurrence of the 910 identified spots was analysed throughout the gels and represented in a virtual 2D gel. Sixteen percent of the spots were found to occur in all samples and 23% occurred in at least 90% of urines. About 13% of the protein spots were present only in 10% or less of the samples, thus representing the most variable part of the normal urinary proteome. Twenty proteins corresponding to a fraction of the fully conserved spots were identified by mass spectrometry. In conclusion, a "public" urinary proteome, common to healthy individuals, seems to coexist with a "private" urinary proteome, which is more specific to each individual. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Cytotoxic drug residues in urine of dogs receiving anticancer chemotherapy.

    PubMed

    Knobloch, A; Mohring, S A I; Eberle, N; Nolte, I; Hamscher, G; Simon, D

    2010-01-01

    The presence of cytotoxic drug residues in urine of dogs may represent an exposure risk for pet owners and other people as well as a potential environmental contaminant. However, studies on cytotoxic drug residues in excretions of clinical patients are lacking in veterinary oncology. Variable concentrations of cytotoxic residues are present in urine samples, depending on sampling time and substance. Client-owned dogs with lymphoma or mast cell tumors treated with standard chemotherapy protocols. Urine samples were collected before, directly after, and on days after administration of chemotherapy. Measurement of vincristine, vinblastine, cyclophosphamide, and doxorubicin residues in canine urine was performed by a quantitative liquid chromatography tandem mass spectrometry (LC/MS/MS) method. Median cyclophosphamide residue concentration was 398.2 microg/L directly after treatment (d0) and was below the level of detection on days 1-3 (d1, d2, d3). Median vincristine residue concentration was 53.8 microg/L directly after treatment and was 20.2, 11.4, and 6.6 microg/L on days 1, 2, and 3. Median vinblastine residues were 144.9 (d0), 70.8 (d1), 35.6 (d2), and 18.7 microg/L (d3) with low concentrations detectable for 7 days after treatment. Median urine doxorubicin concentrations were 354.0 (d0), 165.6 (d1), 156.9 (d2), and 158.2 microg/L (d3). Low concentrations of doxorubicin were measurable up to 21 days after administration. Variable concentrations of chemotherapeutics were measured in urine samples, depending on sampling time point and drug. Findings may inform current chemoprotection guidelines and help minimize exposure risks.

Top