Van Der Pol, Barbara; Quinn, Thomas C.; Gaydos, Charlotte A.; Crotchfelt, Kimberly; Schachter, Julius; Moncada, Jeanne; Jungkind, D.; Martin, David H.; Turner, Buffy; Peyton, Cynthia; Jones, Robert B.
2000-01-01
The fully automated COBAS AMPLICOR CT/NG and semiautomated AMPLICOR CT/NG tests were evaluated in a multicenter trial for the ability to detect Chlamydia trachomatis infections. Test performance compared to that of culture was evaluated for 2,236 matched endocervical swab and urine specimens obtained from women and for 1,940 matched urethral swab and urine specimens obtained from men. Culture-negative, PCR-positive specimens that tested positive in a direct fluorescent-antibody test or in a confirmatory PCR test for an alternative target sequence were resolved as true positives. The overall prevalences of chlamydia were 2.4% in women and 7.2% in men. The COBAS AMPLICOR and AMPLICOR formats yielded concordant results for 98.1% of the specimens. With the infected patient as the reference standard, the resolved sensitivities of COBAS AMPLICOR were 89.7% for endocervical swab specimens, 89.2% for female urine specimens, 88.6% for male urethral swab specimens, and 90.3% for male urine specimens. When results were analyzed as if only a single test had been performed on a single specimen type, the resolved sensitivity was always higher. The resolved specificities of PCR were 99.4% for endocervical swab specimens, 99.0% for female urine specimens, 98.7% for male urethral swab specimens, and 98.4% for male urine specimens. The internal control revealed that 2.4% of the specimens were inhibitory when initially tested. Nevertheless, valid results were obtained for 98.6% of the specimens because 59.1% of the inhibitory specimens were not inhibitory when a second aliquot was tested. The COBAS AMPLICOR and AMPLICOR CT/NG tests for C. trachomatis exhibited equally high sensitivity and specificity with both urogenital swab and urine specimens and thus are well suited for screening for C. trachomatis infection. PMID:10699004
Tanaka, M.; Nakayama, H.; Sagiyama, K.; Haraoka, M.; Yoshida, H.; Hagiwara, T.; Akazawa, K.; Naito, S.
2000-01-01
Aims—To compare the performance of a new generation dual amplified enzyme immunoassay (EIA) with a molecular method for the diagnosis of Chlamydia trachomatis, using a range of urogenital samples, and to assess the reliability of testing self collected vaginal specimens compared with clinician collected vaginal specimens. Methods—Two population groups were tested. For the first population group, first void urine samples were collected from 193 male patients with urethritis, and endocervical swabs were collected from 187 high risk commercial sex workers. All urine and endocervical specimens were tested by a conventional assay (IDEIA chlamydia), a new generation amplified immunoassay (IDEIA PCE chlamydia), and the Amplicor polymerase chain reaction (PCR). Discrepant results obtained among the three sample types were confirmed using a nested PCR test with a different plasmid target region. For the second population group, four swab specimens, including one patient obtained vaginal swab, two clinician obtained endocervical swabs, and one clinician obtained vaginal swab, were collected from 91 high risk sex workers. Self collected and clinician collected vaginal swabs were tested by IDEIA PCE chlamydia. Clinician obtained endocervical swabs were assayed by IDEIA PCE chlamydia and Amplicor PCR. Results—The performance of the IDEIA PCE chlamydia test was comparable to that of the Amplicor PCR test when male urine and female endocervical swab specimens were analysed. The relative sensitivities of IDEIA, IDEIA PCE, and Amplicor PCR on male first void urine specimens were 79.3%, 91.4%, and 100%, respectively. The relative sensitivities of the three tests on female endocervical specimens were 85.0%, 95.0%, and 100%, respectively. The positivity rates for patient collected vaginal specimens and clinician collected vaginal specimens by IDEIA PCE were 25.2% and 23.1%, respectively, whereas those for clinician collected endocervical swabs by PCR and IDEIA PCE were both 27.5%. Conclusions—IDEIA PCE chlamydia is a lower cost but sensitive alternative test to PCR for testing male urine samples and female endocervical swabs. In addition, self collected or clinician collected vaginal specimens tested by IDEIA PCE chlamydia are a reliable alternative to analysing endocervical specimens. Key Words: Chlamydia trachomatis • enzyme immunoassay • clinical specimens PMID:10889816
Senkomago, V; Des Marais, A C; Rahangdale, L; Vibat, C R T; Erlander, M G; Smith, J S
2016-01-01
Urine testing for high-risk human papillomavirus (HR-HPV) detection could provide a non-invasive, simple method for cervical cancer screening. We examined whether HR-HPV detection is affected by urine collection time, portion of urine stream, or urine fraction tested, and assessed the performance of HR-HPV testing in urine for detection of cervical intraepithelial neoplasia grade II or worse (CIN2+). A total of 37 female colposcopy clinic attendees, ≥ 30 years, provided three urine samples: "first void" urine collected at home, and "initial stream" and "mid-stream" urine samples collected at the clinic later in the day. Self- and physician-collected brush specimens were obtained at the same clinic visit. Colposcopy was performed and directed biopsies obtained if clinically indicated. For each urine sample, HR-HPV DNA testing was conducted for unfractionated, pellet, and supernatant fractions using the Trovagene test. HR-HPV mRNA testing was performed on brush specimens using the Aptima HPV assay. HR-HPV prevalence was similar in unfractionated and pellet fractions of all urine samples. For supernatant urine fractions, HR-HPV prevalence appeared lower in mid-stream urine (56.8%[40.8-72.7%]) than in initial stream urine (75.7%[61.9-89.5%]). Sensitivity of CIN2+ detection was identical for initial stream urine and physician-collected cervical specimen (89.9%[95%CI=62.7-99.6%]), and similar to self-collected vaginal specimen (79.1%[48.1-96.6%]). This is among the first studies to compare methodologies for collection and processing of urine for HR-HPV detection. HR-HPV prevalence was similar in first void and initial stream urine, and was highly sensitive for CIN2+ detection. Additional research in a larger and general screening population is needed. Copyright © 2015 Elsevier B.V. All rights reserved.
Nibhanipudi, Kumara V
2016-01-01
To determine the incidence of urinary tract infections (UTIs) in infants and children (4 months to 6 years of age) with febrile diarrhea, as outpatients. This was a prospective institutional review board-approved study. patients (between 4 months and 6 years of age) were enrolled in the study who presented to the pediatric emergency room with a complaint of fever (rectal temperature 101°F or more) and diarrhea (watery stools >3 in number). The patients were evaluated for state of hydration, and also urine samples were collected. For those children not toilet trained, urine specimens were collected by bladder catheterization, and for those children toilet trained, urine specimens were obtained by midstream collection method. The urine samples obtained were sent for analysis and culture. Eighty patients were enrolled in the study. The number of specimens obtained by clean catch midstream was 20, and by bladder catheterization was 60. None of the urine specimens obtained by both methods of collection grew any organism. There was no increased incidence of infections in male children whether circumcised (10/60) or uncircumcised (50/60). The mean temperature was 102.8°F (range = 101°F to 105°F). Using in silico online 2 × 2 χ(2) test by comparing both the positive and negative urine culture results, 2-tailed P value is <.0001. Our prospective randomized study concluded that there is no increased incidence of UTIs in infants and children (4 months to 6 years of age) with febrile diarrhea.
White, Robert M; Mitchell, John M; Hart, E Dale; Evans, Amy; Meaders, Meredith; Norsworthy, Sarah E; Hayes, Eugene D; Flegel, Ron; Maha, George C; Shaffer, Megan D; Hall, Erin M; Rogers, Kelley
2018-02-01
For forensic biological sample collections, the specimen donor is linked solidly to his or her specimen through a chain of custody (CoC) sometimes referenced as a chain of evidence. Rarely, a donor may deny that a urine or oral fluid (OF) specimen is his or her specimen even with a patent CoC. The goal of this pilot study was to determine the potential effects of short-term storage on the quality and quantity of DNA in both types of specimen under conditions that may be encountered with employment-related drug testing specimens. Fresh urine and freshly collected oral fluid all produced complete STR profiles. For the "pad" type OF collectors, acceptable DNA was extractable both from the buffer/preservative and the pad. Although fresh urine and OF produced complete STR profiles, partial profiles were obtained after storage for most samples. An exception was the DNA in the Quantisal OF collector, from which a complete profile was obtained for both freshly collected OF and stored OF. Copyright © 2017 Elsevier B.V. All rights reserved.
Antibiotic Screening of Urine Culture for Internal Quality Audit at Amrita Hospital, Kochi.
Suresh, Aswathy; Gopinathan, Anusha; Dinesh, Kavitha R; Kumar, Anil
2017-07-01
Urine antimicrobial activity is a seldom analysed laboratory test which greatly impacts the quantification of urine specimens. Presence of antimicrobial activity in the urine reduces the bacterial load in these specimens. Hence, the chances of erroneously reporting insignificant bacteriuria can be reduced on analysis of the antimicrobial activity in urine. The aim of the study was to measure the antimicrobial activity of urine samples obtained from patients in a tertiary care hospital. A total of 100 urine specimens were collected from the study group. Tests like wet mount, Gram staining and culture were performed. Antimicrobial susceptibility testing was done on the bacteria isolated from each specimen. The urine specimens were reported as significant bacteriuria (>105 Colony Forming Unit (CFU)/ml) and insignificant bacteriuria (<105 CFU/ml - clean catch midstream urine; <102 CFU/ml - catheterized urine sample) according to the CFU/ml. Staphylococcus aureus ATCC ® 25923 ™ and Escherichia coli ATCC ® 25922 ™ were used to identify the presence of antimicrobial activity in the urine sample by Urine Anti-Bacterial substance Assay (UABA). McNemar test was used for statistical analysis using Statistical Package for the Social Sciences (SPSS) version 21.0. On analysis of the antimicrobial activity of urine sample with the prior antibiotic history of the patients, 17 were true positives and 43 were true negatives. Twenty six of samples with UABA positivity were culture negative and 28 samples with UABA positivity were culture positive. Sensitivity and specificity of the test was 85% and 53.8% respectively. Accuracy of the test was 60%. The p-value of UABA was <0.001. Enterobacteriaceae was the most common bacterial family isolated from the urine specimens. A total of 85% patients responded to treatment. Presence of antimicrobial activity in urine has a great impact on the interpretation of urine culture reports. Identification of urine antimicrobial activity helps in evaluating the quantification of bacterial growth reported in urine culture. It facilitates speedy recovery of patients by early administration of antibiotics.
Reisfield, Gary M; Goldberger, Bruce A; Crews, Bridgit O; Pesce, Amadeo J; Wilson, George R; Teitelbaum, Scott A; Bertholf, Roger L
2011-03-01
To assess the degree of ethanol absorption and subsequent formation of urinary ethyl glucuronide (EtG) and ethyl sulfate (EtS) following sustained application of hand sanitizer, 11 volunteers cleansed their hands with Purell(™) hand sanitizer (62% ethanol) every 5 min for 10 h on three consecutive days. Urine specimens were obtained at the beginning and end of each day of the study, and on the morning of the fourth day. Urinary creatinine, ethanol, EtG, and EtS concentrations were measured. EtG was undetectable in all pre-study urine specimens, but two pre-study specimens had detectable EtS (73 and 37 ng/mL). None of the pre-study specimens had detectable ethanol. The maximum EtG and EtS concentrations over the course of the study were 2001 and 84 ng/mL, respectively, and nearly all EtG- and EtS-positive urine specimens were collected at the conclusion of the individual study days. Only two specimens had detectable EtG at the beginning of any study day (96 and 139 ng/mL), and only one specimen had detectable EtS at the beginning of a study day (64 ng/mL), in addition to the two with detectable EtS prior to the study. Creatinine-adjusted maximum EtG and EtS concentrations were 1998 and 94 μg/g creatinine, respectively. In patients being monitored for ethanol use by urinary EtG concentrations, currently accepted EtG cutoffs do not distinguish between ethanol consumption and incidental exposures, particularly when urine specimens are obtained shortly after sustained use of ethanolcontaining hand sanitizer. Our data suggest that EtS may be an important complementary biomarker in distinguishing ethanol consumption from dermal exposure.
Théron, Marie-Laure; Piane, Laetitia; Lucarelli, Laetitia; Henrion, Rémi; Layssol-Lamour, Catherine; Palanché, Florence; Concordet, Didier; Braun, Jean-Pierre D; Trumel, Catherine; Lavoué, Rachel
2017-08-01
OBJECTIVE To investigate effects of storage conditions on the canine urine protein-to-creatinine ratio (UPC) and on SDS-agarose gel electrophoresis (AGE) of urinary proteins. SAMPLE Urine specimens from 20 proteinuric (UPC > 0.5) and 20 nonproteinuric (UPC ≤ 0.2) dogs. PROCEDURES UPC and SDS-AGE were performed on urine specimens stored at room temperature (20°C) and 4°C for up to 5 days and at -20° and -80°C for up to 360 days; some specimens were subjected to 3 freeze-thaw cycles. Results were compared with those obtained for fresh urine specimens. RESULTS UPC was not affected by storage at room temperature or by freezing. A decrease in UPC was observed for specimens from nonproteinuric dogs after 5 days at 4°C (10%) and from both groups after 90 days at -20° and -80°C (≤ 20% and ≤ 15%, respectively). The SDS-AGE profiles revealed no visual changes regardless of duration of storage for specimens stored at room temperature, 4°C, and -80°C, except for 1 profile after 360 days at -80°C. Repeated freeze-thaw cycles did not affect SDS-AGE profiles. Appearance or strengthening of high-molecular-weight bands that could alter interpretation was evident in SDS-AGE profiles after storage at -20°C for ≥ 15 days (31/40 dogs). CONCLUSIONS AND CLINICAL RELEVANCE Storage of urine at -20° or -80°C for up to 1 year influenced the UPC without affecting clinical interpretation. Storage of urine specimens at -20°C impaired visual analysis of SDS-AGE. When SDS-AGE cannot be performed on fresh or recently refrigerated urine specimens, storage at -80°C is recommended.
Pitfalls of diagnosing urinary tract infection in infants and young children.
Yamasaki, Yasuhito; Uemura, Osamu; Nagai, Takuhito; Yamakawa, Satoshi; Hibi, Yoshiko; Yamamoto, Masaki; Nakano, Masaru; Kasahara, Katsuaki; Bo, Zhang
2017-07-01
The aim of this study was to examine the sensitivity and specificity of pyuria-based diagnosis of urinary tract infection (UTI) in urine collected by transurethral catheterization, and the reliability of diagnosis of pyuria in urine collected in a perineal bag. The gold standard for UTI diagnosis is significant colony counts of a single organism in urine obtained in a sterile manner. We enrolled 301 patients who underwent medical examination at the present hospital for possible UTI between January 2005 and December 2009. We collected 438 urine samples by transurethral catheterization. We investigated the accuracy of pyuria-based diagnosis of UTI using transurethral catheterization urine specimens, and the reliability of diagnosis of pyuria using bag-collected urine specimens. The false-negative rate of UTI diagnosis based on pyuria in transurethral catheterization urine sediments was 9.0%; there was no significant difference in the false-negative rate of UTI diagnosis between boys and girls. Approximately 28% of pyuria-positive bag-collected urine specimens were pyuria negative on transurethral catheterization; this rate was significantly higher in girls than in boys (56.7% vs. 8.9%, P < 0.0001). The absence of pyuria in transurethral catheterization urine sediments does not rule out UTI. Pyuria in bag-collected urine specimens frequently consists of urine leukocytes from external genitalia as well as from the urinary tract. © 2017 Japan Pediatric Society.
Kuwayama, Kenji; Miyaguchi, Hajime; Yamamuro, Tadashi; Tsujikawa, Kenji; Kanamori, Tatsuyuki; Iwata, Yuko T; Inoue, Hiroyuki
2016-07-01
In forensic drug testing, it is important to immediately take biological specimens from suspects and victims to prove their drug intake. We evaluated the effectiveness of saliva and fingerprints as alternative specimens to urine and blood in terms of ease of sampling, drug detection sensitivity, and drug detection periods for each specimen type. After four commercially available pharmaceutical products were administered to healthy subjects, each in a single dose, their urine, blood, saliva, and fingerprints were taken at predetermined sampling times over approximately four weeks. Fourteen analytes (the administered drugs and their main metabolites) were extracted from each specimen using simple pretreatments, such as dilution and deproteinization, and were analyzed using liquid chromatography/mass spectrometry (LC/MS). Most of the analytes were detected in saliva and fingerprints, as well as in urine and blood. The time-courses of drug concentrations were similar between urine and fingerprints, and between blood and saliva. Compared to the other compounds, the acidic compounds, for example ibuprofen, acetylsalicylic acid, were more difficult to detect in all specimens. Acetaminophen, dihydrocodeine, and methylephedrine were detected in fingerprints at later sampling times than in urine. However, a relationship between the drug structures and their detection periods in each specimen was not found. Saliva and fingerprints could be easily sampled on site without using special techniques or facilities. In addition, fingerprints could be immediately analyzed after simple and rapid treatment. In cases where it would be difficult to immediately obtain urine and blood, saliva and fingerprints could be effective alternative specimens for drug testing. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
40 CFR 160.195 - Retention of records.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., terminated, or discontinued. (c) Wet specimens, samples of test, control, or reference substances, and... storage, shall be retained only as long as the quality of the preparation affords evaluation. Specimens obtained from mutagenicity tests, specimens of soil, water, and plants, and wet specimens of blood, urine...
Automated Microbiological Detection/Identification System
Aldridge, C.; Jones, P. W.; Gibson, S.; Lanham, J.; Meyer, M.; Vannest, R.; Charles, R.
1977-01-01
An automated, computerized system, the AutoMicrobic System, has been developed for the detection, enumeration, and identification of bacteria and yeasts in clinical specimens. The biological basis for the system resides in lyophilized, highly selective and specific media enclosed in wells of a disposable plastic cuvette; introduction of a suitable specimen rehydrates and inoculates the media in the wells. An automated optical system monitors, and the computer interprets, changes in the media, with enumeration and identification results automatically obtained in 13 h. Sixteen different selective media were developed and tested with a variety of seeded (simulated) and clinical specimens. The AutoMicrobic System has been extensively tested with urine specimens, using a urine test kit (Identi-Pak) that contains selective media for Escherichia coli, Proteus species, Pseudomonas aeruginosa, Klebsiella-Enterobacter species, Serratia species, Citrobacter freundii, group D enterococci, Staphylococcus aureus, and yeasts (Candida species and Torulopsis glabrata). The system has been tested with 3,370 seeded urine specimens and 1,486 clinical urines. Agreement with simultaneous conventional (manual) cultures, at levels of 70,000 colony-forming units per ml (or more), was 92% or better for seeded specimens; clinical specimens yielded results of 93% or better for all organisms except P. aeruginosa, where agreement was 86%. System expansion in progress includes antibiotic susceptibility testing and compatibility with most types of clinical specimens. Images PMID:334798
21 CFR 58.195 - Retention of records.
Code of Federal Regulations, 2010 CFR
2010-04-01
... specimens (except those specimens obtained from mutagenicity tests and wet specimens of blood, urine, feces, and biological fluids), samples of test or control articles, and specially prepared material, which are relatively fragile and differ markedly in stability and quality during storage, shall be retained...
Evaluation of abalone β-glucuronidase substitution in current urine hydrolysis procedures.
Malik-Wolf, Brittany; Vorce, Shawn; Holler, Justin; Bosy, Thomas
2014-04-01
This study examined the potential of abalone β-glucuronidase as a viable and cost effective alternative to current hydrolysis procedures using acid, Helix pomatia β-glucuronidase and Escherichia coli β-glucuronidase. Abalone β-glucuronidase successfully hydrolyzed oxazepam-glucuronide and lorazepam-glucuronide within 5% of the spiked control concentration. Benzodiazepines present in authentic urine specimens were within 20% of the concentrations obtained with the current hydrolysis procedure using H. pomatia β-glucuronidase. JWH 018 N-(5-hydroxypentyl) β-d-glucuronide was hydrolyzed within 10% of the control concentration. Authentic urine specimens showed improved glucuronide cleavage using abalone β-glucuronidase with up to an 85% increase of drug concentration, compared with the results obtained using E. coli β-glucuronidase. The JWH 018 and JWH 073 carboxylic acid metabolites also showed increased drug concentrations of up to 24%. Abalone β-glucuronidase was able to completely hydrolyze a morphine-3-glucuronide control, but only 82% of total morphine was hydrolyzed in authentic urine specimens compared with acid hydrolysis results. Hydrolysis of codeine and hydromorphone varied between specimens, suggesting that abalone β-glucuronidase may not be as efficient in hydrolyzing the glucuronide linkages in opioid compounds compared with acid hydrolysis. Abalone β-glucuronidase demonstrates effectiveness as a low cost option for enzyme hydrolysis of benzodiazepines and synthetic cannabinoids.
SERS quantitative urine creatinine measurement of human subject
NASA Astrophysics Data System (ADS)
Wang, Tsuei Lian; Chiang, Hui-hua K.; Lu, Hui-hsin; Hung, Yung-da
2005-03-01
SERS method for biomolecular analysis has several potentials and advantages over traditional biochemical approaches, including less specimen contact, non-destructive to specimen, and multiple components analysis. Urine is an easily available body fluid for monitoring the metabolites and renal function of human body. We developed surface-enhanced Raman scattering (SERS) technique using 50nm size gold colloidal particles for quantitative human urine creatinine measurements. This paper shows that SERS shifts of creatinine (104mg/dl) in artificial urine is from 1400cm-1 to 1500cm-1 which was analyzed for quantitative creatinine measurement. Ten human urine samples were obtained from ten healthy persons and analyzed by the SERS technique. Partial least square cross-validation (PLSCV) method was utilized to obtain the estimated creatinine concentration in clinically relevant (55.9mg/dl to 208mg/dl) concentration range. The root-mean square error of cross validation (RMSECV) is 26.1mg/dl. This research demonstrates the feasibility of using SERS for human subject urine creatinine detection, and establishes the SERS platform technique for bodily fluids measurement.
Dasgupta, Amitava; Chughtai, Omar; Hannah, Christina; Davis, Bonnette; Wells, Alice
2004-10-01
Several adulterants are used to mask tests for abused drugs in urine. Adulterants such as "Klear" and "Whizzies" contain potassium nitrite while "Urine Luck" contains pyridinium chlorochromate (PCC). The presence of these adulterants cannot be detected by routine specimen integrity check (pH, specific gravity, creatinine and temperature). We previously reported the development of rapid spot tests to detect the presence of these adulterants. AdultaCheck 6 and Intect 7 urine test strips are commercially available for detecting the presence of these adulterants along with specific gravity, creatinine and pH in urine. The performance of these two test strips for detecting adulterants was compared with the results obtained by spot tests. Both AdultaCheck 6 and Intect 7 effectively detected the presence of nitrite and pyridinium chlorochromate in urine. Moreover, both test strips successfully detected the presence of glutaraldehyde, for which no spot test is currently available. High amount of glucose and ascorbic acid did not cause any false positive result with AdultaCheck 6 or Intect 7. Both AdultaCheck 6 and Intect 7 can be used for checking the integrity of a urine specimen submitted for drugs of abuse testing.
Schroeder, Alan R; Newman, Thomas B; Wasserman, Richard C; Finch, Stacia A; Pantell, Robert H
2005-10-01
The optimal method of urine collection in febrile infants is debatable; catheterization, considered more accurate, is technically difficult and invasive. To determine predictors of urethral catheterization in febrile infants and to compare bag and catheterized urine test performance characteristics. Prospective analysis of infants enrolled in the Pediatric Research in Office Settings' Febrile Infant Study. A total of 219 practices from within the Pediatric Research in Office Settings' network, including 44 states, the District of Columbia, and Puerto Rico. A total of 3066 infants aged 0 to 3 months with temperatures of 38 degrees C or higher. We calculated adjusted odds ratios for predictors of catheterization. Diagnostic test characteristics were compared between bag and catheterization. Urinary tract infection was defined as pure growth of 100 000 CFU/mL or more (bag) and 20 000 CFU/mL or more (catheterization). Seventy percent of urine samples were obtained by catheterization. Predictors of catheterization included female sex, practitioner older than 40 years, Medicaid, Hispanic ethnicity, nighttime evaluation, and severe dehydration. For leukocyte esterase levels, bag specimens demonstrated no difference in sensitivity but somewhat lower specificity (84% [bag] vs 94% [catheterization], P<.001) and a lower area under the receiver operating characteristic curve for white blood cells (0.71 [bag] vs 0.86 [catheterization], P = .01). Infection rates were similar in bag and catheterized specimens (8.5% vs 10.8%). Ambiguous cultures were more common in bag specimens (7.4% vs 2.7%, P<.001), but 21 catheterized specimens are needed to avoid each ambiguous bag result. Most practitioners obtain urine from febrile infants via catheterization, but choice of method is not related to the risk of urinary tract infection. Although both urine cultures and urinalyses are more accurate in catheterized specimens, the magnitude of difference is small but should be factored into clinical decision making.
Adulterants in Urine Drug Testing.
Fu, S
Urine drug testing plays an important role in monitoring licit and illicit drug use for both medico-legal and clinical purposes. One of the major challenges of urine drug testing is adulteration, a practice involving manipulation of a urine specimen with chemical adulterants to produce a false negative test result. This problem is compounded by the number of easily obtained chemicals that can effectively adulterate a urine specimen. Common adulterants include some household chemicals such as hypochlorite bleach, laundry detergent, table salt, and toilet bowl cleaner and many commercial products such as UrinAid (glutaraldehyde), Stealth® (containing peroxidase and peroxide), Urine Luck (pyridinium chlorochromate, PCC), and Klear® (potassium nitrite) available through the Internet. These adulterants can invalidate a screening test result, a confirmatory test result, or both. To counteract urine adulteration, drug testing laboratories have developed a number of analytical methods to detect adulterants in a urine specimen. While these methods are useful in detecting urine adulteration when such activities are suspected, they do not reveal what types of drugs are being concealed. This is particularly the case when oxidizing urine adulterants are involved as these oxidants are capable of destroying drugs and their metabolites in urine, rendering the drug analytes undetectable by any testing technology. One promising approach to address this current limitation has been the use of unique oxidation products formed from reaction of drug analytes with oxidizing adulterants as markers for monitoring drug misuse and urine adulteration. This novel approach will ultimately improve the effectiveness of the current urine drug testing programs. © 2016 Elsevier Inc. All rights reserved.
Office diagnosis of asymptomatic bacteriuria in pregnant women.
Van Dorsten, J P; Bannister, E R
1986-10-01
Diagnosis and treatment of asymptomatic bacteriuria in pregnant patients can virtually eliminate pyelonephritis, the most common medical cause for antepartum hospitalization. However, the ever-increasing cost of the urine culture has led most clinicians away from routine urine screening. Uricult dip-slide paddles provide an inexpensive, efficient way to screen urine. Clean-catch urine specimens were obtained from 544 consecutive asymptomatic pregnant patients seen in the outpatient obstetric clinic at the Medical University of South Carolina. Specimens were analyzed by both traditional culture techniques and the Uricult dip-slide paddles. By comparison, the Uricult test detected 55 of the 56 significant gram-negative urinary pathogens found by culture. Detection of potential gram-positive pathogens is more difficult. A scheme is proposed that allows reliable, inexpensive surveillance in all pregnant patients. Hopefully, this algorithm will rekindle the obstetrician's interest in urine screening.
Timing of specimen collection is crucial in urine screening of drug dependent mothers and newborns.
Halstead, A C; Godolphin, W; Lockitch, G; Segal, S
1988-01-01
We compared results of urine drug analysis with clinical data and history to test the usefulness of peripartum drug screening and to establish guidelines for optimal testing. Urine from 28 mothers and 52 babies was analysed. Drugs not suspected by history were found in 10 mothers and six babies. Results assisted in the management of neonatal withdrawal in three babies. Drugs suspected by history were not found in 11/22 mothers and 23/35 babies. About half of these results were associated with delayed urine collection. In 12/28 mothers, drugs administered in hospital could have confused interpretation of screen results. We conclude that urine drug screening without strict protocols for specimen collection is of limited usefulness for management of drug abuse in pregnancy and neonatal drug withdrawal. We favour testing of maternal urine obtained before drugs are administered in hospital. Neonatal urine, if used, should be collected in the first day of life.
Telomerase activity in solid transitional cell carcinoma, bladder washings, and voided urine.
Lance, R S; Aldous, W K; Blaser, J; Thrasher, J B
1998-03-04
Telomerase activity has been detected in a wide variety of human malignancies. It appears to be one of the fundamental ingredients necessary for cellular immortality. We sought to determine the incidence of telomerase activity in solid transitional cell carcinoma (TCC) specimens, benign urothelium, bladder washings, and voided urine from patients with TCC identified cystoscopically compared with controls. Telomerase activity was measured in 26 solid bladder cancers and 13 benign urothelial specimens using the telomere repeat amplification protocol (TRAP), a polymerase chain reaction (PCR) based assay. Telomerase activity was further measured in the centrifuged cellular material obtained from the bladder washings of 26 patients with TCC and 40 with benign urologic disease found to have a normal cystoscopy. All patients with hematuria were additionally evaluated with an upper tract radiographic examination and found to be free of malignancy. Voided urine was likewise evaluated in 11 patients with TCC, 12 with benign urologic diseases, and 56 asymptomatic control subjects. Telomerase activity was detected in 25 of 26 (96%) solid specimens, 21 of 26 (81%) bladder washings, and 6 of 11 (54%) voided urine specimens from patients with histologically confirmed TCC. In the control group, 2 of 13 (15%) benign urothelial specimens and 2 of 56 (4%) voided urine specimens from the asymptomatic volunteer group demonstrated telomerase activity. Of those with benign urologic disease, 16 of 40 (40%) bladder barbotage specimens and 6 of 12 (50%) voided urine specimens demonstrated telomerase activity. Sensitivity and specificity of telomerase as a marker for TCC were 81% and 60%, respectively, in the bladder washings group and 54% and 50%, respectively, in voided urine. These data indicate that activation of telomerase is frequent in solid TCC and appears to be a sensitive marker in bladder washings of patients with TCC. We noted an unexpectedly high false positive detection rate in patients with benign urologic diseases, especially those with symptomatic benign prostatic hyperplasia. An additional study of a larger number of both bladder cancer patients and those at risk is necessary to determine if telomerase activity could play a role as a diagnostic and/or surveillance marker of TCC. Published by Elsevier Science Inc.
Shi, Yingai; Bharadwaj, Shantaram; Leng, Xiaoyan; Zhou, Xiaobo; Liu, Hong; Atala, Anthony; Zhang, Yuanyuan
2013-01-01
Despite successful approaches to preserve organs, tissues, and isolated cells, the maintenance of stem cell viability and function in body fluids during storage for cell distribution and transportation remains unexplored. The aim of this study was to characterize urine-derived stem cells (USCs) after optimal preservation of urine specimens for up to 24 hours. A total of 415 urine specimens were collected from 12 healthy men (age range 20–54 years old). About 6×104 cells shed off from the urinary tract system in 24 hours. At least 100 USC clones were obtained from the stored urine specimens after 24 hours and maintained similar biological features to fresh USCs. The stored USCs had a “rice grain” shape in primary culture, and expressed mesenchymal stem cell surface markers, high telomerase activity, and normal karyotypes. Importantly, the preserved cells retained bipotent differentiation capacity. Differentiated USCs expressed myogenic specific proteins and contractile function when exposed to myogenic differentiation medium, and they expressed urothelial cell-specific markers and barrier function when exposed to urothelial differentiation medium. These data demonstrated that up to 75% of fresh USCs can be safely persevered in urine for 24 hours and that these cells stored in urine retain their original stem cell properties, indicating that preserved USCs could be available for potential use in cell-based therapy or clinical diagnosis. PMID:23349776
Value of Routine Dengue Diagnostic Tests in Urine and Saliva Specimens
Andries, Anne-Claire; Duong, Veasna; Ly, Sowath; Cappelle, Julien; Kim, Kim Srorn; Lorn Try, Patrich; Ros, Sopheaktra; Ong, Sivuth; Huy, Rekol; Horwood, Paul; Flamand, Marie; Sakuntabhai, Anavaj; Tarantola, Arnaud; Buchy, Philippe
2015-01-01
Background Dengue laboratory diagnosis is essentially based on detection of the virus, its components or antibodies directed against the virus in blood samples. Blood, however, may be difficult to draw in some patients, especially in children, and sampling during outbreak investigations or epidemiological studies may face logistical challenges or limited compliance to invasive procedures from subjects. The aim of this study was to assess the possibility of using saliva and urine samples instead of blood for dengue diagnosis. Methodology/Principal Findings Serial plasma, urine and saliva samples were collected at several time-points between the day of admission to hospital until three months after the onset of fever in children with confirmed dengue disease. Quantitative RT-PCR, NS1 antigen capture and ELISA serology for anti-DENV antibody (IgG, IgM and IgA) detection were performed in parallel on the three body fluids. RT-PCR and NS1 tests demonstrated an overall sensitivity of 85.4%/63.4%, 41.6%/14.5% and 39%/28.3%, in plasma, urine and saliva specimens, respectively. When urine and saliva samples were collected at the same time-points and tested concurrently, the diagnostic sensitivity of RNA and NS1 detection assays was 69.1% and 34.4%, respectively. IgG/IgA detection assays had an overall sensitivity of 54.4%/37.4%, 38.5%/26.8% and 52.9%/28.6% in plasma, urine and saliva specimens, respectively. IgM were detected in 38.1% and 36% of the plasma and saliva samples but never in urine. Conclusions Although the performances of the different diagnostic methods were not as good in saliva and urine as in plasma specimens, the results obtained by qRT-PCR and by anti-DENV antibody ELISA could well justify the use of these two body fluids to detect dengue infection in situations when the collection of blood specimens is not possible. PMID:26406240
Urine specimen validity test for drug abuse testing in workplace and court settings.
Lin, Shin-Yu; Lee, Hei-Hwa; Lee, Jong-Feng; Chen, Bai-Hsiun
2018-01-01
In recent decades, urine drug testing in the workplace has become common in many countries in the world. There have been several studies concerning the use of the urine specimen validity test (SVT) for drug abuse testing administered in the workplace. However, very little data exists concerning the urine SVT on drug abuse tests from court specimens, including dilute, substituted, adulterated, and invalid tests. We investigated 21,696 submitted urine drug test samples for SVT from workplace and court settings in southern Taiwan over 5 years. All immunoassay screen-positive urine specimen drug tests were confirmed by gas chromatography/mass spectrometry. We found that the mean 5-year prevalence of tampering (dilute, substituted, or invalid tests) in urine specimens from the workplace and court settings were 1.09% and 3.81%, respectively. The mean 5-year percentage of dilute, substituted, and invalid urine specimens from the workplace were 89.2%, 6.8%, and 4.1%, respectively. The mean 5-year percentage of dilute, substituted, and invalid urine specimens from the court were 94.8%, 1.4%, and 3.8%, respectively. No adulterated cases were found among the workplace or court samples. The most common drug identified from the workplace specimens was amphetamine, followed by opiates. The most common drug identified from the court specimens was ketamine, followed by amphetamine. We suggest that all urine specimens taken for drug testing from both the workplace and court settings need to be tested for validity. Copyright © 2017. Published by Elsevier B.V.
Eisinger, Stephen W; Schwartz, Matthew; Dam, Lisa; Riedel, Stefan
2013-09-01
The stability of urine specimens submitted for culture remains a challenge for many laboratories because of delays in specimen transport. We evaluated the usefulness of BD Vacutainer Plus Urine C&S Preservative Tube in ensuring specimen stability. Clinical urine specimens collected in sterile collection cups (n = 110) were plated onto sheep blood and MacConkey agar following standard laboratory procedures guidelines. Thereafter, specimens were divided into 3 storage conditions: nonpreservative, refrigerated; nonpreservative, room temperature (RT); BD Vacutainer Plus Urine C&S Preservative Tube, RT. For each sample type, additional cultures were set up at 2, 4, 24, and 48 hours. Initially, 18 specimens had no growth, 32 showed mixed skin flora, and 60 yielded at least 1 uropathogen. Increased colony counts of uropathogens were observed for nonpreserved urine samples stored at RT; these changes were statistically significant. Minor differences between refrigerated urine samples and BD Vacutainer Plus Urine C&S Preservative Tube samples were seen but were not statistically significant. The use of preservative-containing collection tubes is desirable to ensure specimen stability when prompt processing or refrigeration is not feasible.
40 CFR 160.195 - Retention of records.
Code of Federal Regulations, 2012 CFR
2012-07-01
... obtained from mutagenicity tests, specimens of soil, water, and plants, and wet specimens of blood, urine... 40 Protection of Environment 25 2012-07-01 2012-07-01 false Retention of records. 160.195 Section... LABORATORY PRACTICE STANDARDS Records and Reports § 160.195 Retention of records. (a) Record retention...
40 CFR 160.195 - Retention of records.
Code of Federal Regulations, 2014 CFR
2014-07-01
... obtained from mutagenicity tests, specimens of soil, water, and plants, and wet specimens of blood, urine... 40 Protection of Environment 24 2014-07-01 2014-07-01 false Retention of records. 160.195 Section... LABORATORY PRACTICE STANDARDS Records and Reports § 160.195 Retention of records. (a) Record retention...
40 CFR 160.195 - Retention of records.
Code of Federal Regulations, 2013 CFR
2013-07-01
... obtained from mutagenicity tests, specimens of soil, water, and plants, and wet specimens of blood, urine... 40 Protection of Environment 25 2013-07-01 2013-07-01 false Retention of records. 160.195 Section... LABORATORY PRACTICE STANDARDS Records and Reports § 160.195 Retention of records. (a) Record retention...
40 CFR 160.195 - Retention of records.
Code of Federal Regulations, 2011 CFR
2011-07-01
... obtained from mutagenicity tests, specimens of soil, water, and plants, and wet specimens of blood, urine... 40 Protection of Environment 24 2011-07-01 2011-07-01 false Retention of records. 160.195 Section... LABORATORY PRACTICE STANDARDS Records and Reports § 160.195 Retention of records. (a) Record retention...
Mai, Kien T; Ball, Christopher G; Kos, Zuzana; Belanger, Eric C; Islam, Shahidul; Sekhon, Harman
2014-07-01
Cystoscopic urine obtained before the resection of low-grade urothelial carcinoma (LGUC), with adequate cytological sampling of the tumor, frequently revealed the presence of three-dimensional cell groups with disordered nuclei and cellular discohesion (3DDD). 936 cystoscopic urine specimens were categorized into five groups: Group 1 (80 specimens) with biopsy-proven LGUC within 6 months of cytologic examination, Group 2 (23 specimens) with biopsy proven LGUC within 6 to 36 months of cytologic examination, Group 3 (527 specimens) with a history of LGUC but no tumor for a period of greater than 3 years, Group 4 (300 specimens) with no association with LGUC, and Group 5 (6 specimens) with urinary lithiasis. Specimens with scant cellularity accounted for 20% of those in Group 1. For 3DDD in detecting LGUC in adequate cystoscopic urine, the sensitivity was 70%, specificity was 94%. Two- or three-dimensional cell groups with ordered nuclei and/or cellular non-discohesion were often seen in specimens from Groups 4 or 5. The 3DDD was present in a significant number of cases with concurrent negative cystoscopic findings but also positive LGUC in ensuing follow-up. In these cases, 3DDD with or without tumor identified at concurrent cystoscopy were found to be morphologically similar. Furthermore, the presence of 3DDD in 8% of Group 3 likely represents urothelial dysplasia that is not cystoscopically detectable. The high specificity and sensitivity of 3DDD is demonstrated. These findings are consistent with the decreased cell adhesion and disordered nuclear arrangement of low grade urothelial neoplasia. © 2013 Wiley Periodicals, Inc.
10 CFR 26.113 - Splitting the urine specimen.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Splitting the urine specimen. 26.113 Section 26.113 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.113 Splitting the urine specimen. (a) Licensees and other entities may, but are not required to, use split...
10 CFR 26.115 - Collecting a urine specimen under direct observation.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Collecting a urine specimen under direct observation. 26.115 Section 26.115 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.115 Collecting a urine specimen under direct observation. (a) Procedures for...
10 CFR 26.113 - Splitting the urine specimen.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Splitting the urine specimen. 26.113 Section 26.113 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.113 Splitting the urine specimen. (a) Licensees and other entities may, but are not required to, use split...
10 CFR 26.115 - Collecting a urine specimen under direct observation.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Collecting a urine specimen under direct observation. 26.115 Section 26.115 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.115 Collecting a urine specimen under direct observation. (a) Procedures for...
10 CFR 26.115 - Collecting a urine specimen under direct observation.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Collecting a urine specimen under direct observation. 26.115 Section 26.115 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.115 Collecting a urine specimen under direct observation. (a) Procedures for...
10 CFR 26.113 - Splitting the urine specimen.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Splitting the urine specimen. 26.113 Section 26.113 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.113 Splitting the urine specimen. (a) Licensees and other entities may, but are not required to, use split...
10 CFR 26.109 - Urine specimen quantity.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Urine specimen quantity. 26.109 Section 26.109 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.109 Urine specimen quantity. (a) Licensees and other entities who are subject to this subpart shall establish a...
10 CFR 26.115 - Collecting a urine specimen under direct observation.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Collecting a urine specimen under direct observation. 26.115 Section 26.115 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.115 Collecting a urine specimen under direct observation. (a) Procedures for...
10 CFR 26.113 - Splitting the urine specimen.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Splitting the urine specimen. 26.113 Section 26.113 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.113 Splitting the urine specimen. (a) Licensees and other entities may, but are not required to, use split...
10 CFR 26.115 - Collecting a urine specimen under direct observation.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Collecting a urine specimen under direct observation. 26.115 Section 26.115 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.115 Collecting a urine specimen under direct observation. (a) Procedures for...
10 CFR 26.109 - Urine specimen quantity.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Urine specimen quantity. 26.109 Section 26.109 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.109 Urine specimen quantity. (a) Licensees and other entities who are subject to this subpart shall establish a...
10 CFR 26.113 - Splitting the urine specimen.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Splitting the urine specimen. 26.113 Section 26.113 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.113 Splitting the urine specimen. (a) Licensees and other entities may, but are not required to, use split...
49 CFR 40.49 - What materials are used to collect urine specimens?
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 1 2012-10-01 2012-10-01 false What materials are used to collect urine specimens? 40.49 Section 40.49 Transportation Office of the Secretary of Transportation PROCEDURES FOR... in DOT Urine Collections § 40.49 What materials are used to collect urine specimens? For each DOT...
49 CFR 40.49 - What materials are used to collect urine specimens?
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 1 2014-10-01 2014-10-01 false What materials are used to collect urine specimens? 40.49 Section 40.49 Transportation Office of the Secretary of Transportation PROCEDURES FOR... in DOT Urine Collections § 40.49 What materials are used to collect urine specimens? For each DOT...
49 CFR 40.49 - What materials are used to collect urine specimens?
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 1 2013-10-01 2013-10-01 false What materials are used to collect urine specimens? 40.49 Section 40.49 Transportation Office of the Secretary of Transportation PROCEDURES FOR... in DOT Urine Collections § 40.49 What materials are used to collect urine specimens? For each DOT...
49 CFR 40.49 - What materials are used to collect urine specimens?
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 1 2011-10-01 2011-10-01 false What materials are used to collect urine specimens? 40.49 Section 40.49 Transportation Office of the Secretary of Transportation PROCEDURES FOR... in DOT Urine Collections § 40.49 What materials are used to collect urine specimens? For each DOT...
49 CFR 40.49 - What materials are used to collect urine specimens?
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 1 2010-10-01 2010-10-01 false What materials are used to collect urine specimens? 40.49 Section 40.49 Transportation Office of the Secretary of Transportation PROCEDURES FOR... in DOT Urine Collections § 40.49 What materials are used to collect urine specimens? For each DOT...
49 CFR 40.31 - Who may collect urine specimens for DOT drug testing?
Code of Federal Regulations, 2014 CFR
2014-10-01
... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.31 Who may collect urine specimens for DOT drug testing? (a) Collectors meeting the requirements of this subpart are the only persons authorized to collect urine specimens for DOT drug testing. (b) A collector must meet...
49 CFR 40.31 - Who may collect urine specimens for DOT drug testing?
Code of Federal Regulations, 2010 CFR
2010-10-01
... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.31 Who may collect urine specimens for DOT drug testing? (a) Collectors meeting the requirements of this subpart are the only persons authorized to collect urine specimens for DOT drug testing. (b) A collector must meet...
49 CFR 40.31 - Who may collect urine specimens for DOT drug testing?
Code of Federal Regulations, 2012 CFR
2012-10-01
... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.31 Who may collect urine specimens for DOT drug testing? (a) Collectors meeting the requirements of this subpart are the only persons authorized to collect urine specimens for DOT drug testing. (b) A collector must meet...
49 CFR 40.31 - Who may collect urine specimens for DOT drug testing?
Code of Federal Regulations, 2011 CFR
2011-10-01
... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.31 Who may collect urine specimens for DOT drug testing? (a) Collectors meeting the requirements of this subpart are the only persons authorized to collect urine specimens for DOT drug testing. (b) A collector must meet...
49 CFR 40.31 - Who may collect urine specimens for DOT drug testing?
Code of Federal Regulations, 2013 CFR
2013-10-01
... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.31 Who may collect urine specimens for DOT drug testing? (a) Collectors meeting the requirements of this subpart are the only persons authorized to collect urine specimens for DOT drug testing. (b) A collector must meet...
10 CFR 26.117 - Preparing urine specimens for storage and shipping.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Preparing urine specimens for storage and shipping. 26.117 Section 26.117 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.117 Preparing urine specimens for storage and shipping. (a) Both the donor and the collector...
10 CFR 26.117 - Preparing urine specimens for storage and shipping.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Preparing urine specimens for storage and shipping. 26.117 Section 26.117 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.117 Preparing urine specimens for storage and shipping. (a) Both the donor and the collector...
10 CFR 26.117 - Preparing urine specimens for storage and shipping.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Preparing urine specimens for storage and shipping. 26.117 Section 26.117 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.117 Preparing urine specimens for storage and shipping. (a) Both the donor and the collector...
10 CFR 26.107 - Collecting a urine specimen.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Collecting a urine specimen. 26.107 Section 26.107 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.107 Collecting a urine specimen. (a) The collector shall direct the donor to go into the room or stall used for...
10 CFR 26.107 - Collecting a urine specimen.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Collecting a urine specimen. 26.107 Section 26.107 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.107 Collecting a urine specimen. (a) The collector shall direct the donor to go into the room or stall used for...
10 CFR 26.107 - Collecting a urine specimen.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Collecting a urine specimen. 26.107 Section 26.107 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.107 Collecting a urine specimen. (a) The collector shall direct the donor to go into the room or stall used for...
10 CFR 26.107 - Collecting a urine specimen.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Collecting a urine specimen. 26.107 Section 26.107 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.107 Collecting a urine specimen. (a) The collector shall direct the donor to go into the room or stall used for...
10 CFR 26.107 - Collecting a urine specimen.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Collecting a urine specimen. 26.107 Section 26.107 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.107 Collecting a urine specimen. (a) The collector shall direct the donor to go into the room or stall used for...
10 CFR 26.117 - Preparing urine specimens for storage and shipping.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Preparing urine specimens for storage and shipping. 26.117 Section 26.117 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.117 Preparing urine specimens for storage and shipping. (a) Both the donor and the collector...
10 CFR 26.117 - Preparing urine specimens for storage and shipping.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Preparing urine specimens for storage and shipping. 26.117 Section 26.117 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.117 Preparing urine specimens for storage and shipping. (a) Both the donor and the collector...
10 CFR 26.111 - Checking the acceptability of the urine specimen.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Checking the acceptability of the urine specimen. 26.111 Section 26.111 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.111 Checking the acceptability of the urine specimen. (a) Immediately after the donor...
10 CFR 26.111 - Checking the acceptability of the urine specimen.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Checking the acceptability of the urine specimen. 26.111 Section 26.111 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.111 Checking the acceptability of the urine specimen. (a) Immediately after the donor...
49 CFR 40.51 - What materials are used to send urine specimens to the laboratory?
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 1 2013-10-01 2013-10-01 false What materials are used to send urine specimens to the laboratory? 40.51 Section 40.51 Transportation Office of the Secretary of Transportation... and Supplies Used in DOT Urine Collections § 40.51 What materials are used to send urine specimens to...
49 CFR 40.51 - What materials are used to send urine specimens to the laboratory?
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 1 2010-10-01 2010-10-01 false What materials are used to send urine specimens to the laboratory? 40.51 Section 40.51 Transportation Office of the Secretary of Transportation... and Supplies Used in DOT Urine Collections § 40.51 What materials are used to send urine specimens to...
49 CFR 40.51 - What materials are used to send urine specimens to the laboratory?
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 1 2014-10-01 2014-10-01 false What materials are used to send urine specimens to the laboratory? 40.51 Section 40.51 Transportation Office of the Secretary of Transportation... and Supplies Used in DOT Urine Collections § 40.51 What materials are used to send urine specimens to...
49 CFR 40.51 - What materials are used to send urine specimens to the laboratory?
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 1 2011-10-01 2011-10-01 false What materials are used to send urine specimens to the laboratory? 40.51 Section 40.51 Transportation Office of the Secretary of Transportation... and Supplies Used in DOT Urine Collections § 40.51 What materials are used to send urine specimens to...
49 CFR 40.51 - What materials are used to send urine specimens to the laboratory?
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 1 2012-10-01 2012-10-01 false What materials are used to send urine specimens to the laboratory? 40.51 Section 40.51 Transportation Office of the Secretary of Transportation... and Supplies Used in DOT Urine Collections § 40.51 What materials are used to send urine specimens to...
46 CFR 4.06-40 - Specimen handling and shipping.
Code of Federal Regulations, 2012 CFR
2012-10-01
...-four (24) hours of receipt by the carrier. (b) The marine employer shall ensure that the urine specimen..., subpart D, are complied with. The marine employer shall ensure that urine specimens required by §§ 4.06-20.... Urine specimens must be shipped by an expeditious means, but need not be shipped in a cooled condition...
49 CFR 40.71 - How does the collector prepare the specimens?
Code of Federal Regulations, 2011 CFR
2011-10-01
... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.71 How does the... brings the urine specimen to you. You must take these steps in the presence of the employee. (1) Check... employee, must first pour at least 30 mL of urine from the collection container into one specimen bottle...
46 CFR 4.06-40 - Specimen handling and shipping.
Code of Federal Regulations, 2014 CFR
2014-10-01
...-four (24) hours of receipt by the carrier. (b) The marine employer shall ensure that the urine specimen..., subpart D, are complied with. The marine employer shall ensure that urine specimens required by §§ 4.06-20.... Urine specimens must be shipped by an expeditious means, but need not be shipped in a cooled condition...
49 CFR 40.71 - How does the collector prepare the specimens?
Code of Federal Regulations, 2014 CFR
2014-10-01
... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.71 How does the... brings the urine specimen to you. You must take these steps in the presence of the employee. (1) Check... employee, must first pour at least 30 mL of urine from the collection container into one specimen bottle...
46 CFR 4.06-40 - Specimen handling and shipping.
Code of Federal Regulations, 2010 CFR
2010-10-01
...-four (24) hours of receipt by the carrier. (b) The marine employer shall ensure that the urine specimen..., subpart D, are complied with. The marine employer shall ensure that urine specimens required by §§ 4.06-20.... Urine specimens must be shipped by an expeditious means, but need not be shipped in a cooled condition...
49 CFR 40.71 - How does the collector prepare the specimens?
Code of Federal Regulations, 2010 CFR
2010-10-01
... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.71 How does the... brings the urine specimen to you. You must take these steps in the presence of the employee. (1) Check... employee, must first pour at least 30 mL of urine from the collection container into one specimen bottle...
49 CFR 40.71 - How does the collector prepare the specimens?
Code of Federal Regulations, 2012 CFR
2012-10-01
... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.71 How does the... brings the urine specimen to you. You must take these steps in the presence of the employee. (1) Check... employee, must first pour at least 30 mL of urine from the collection container into one specimen bottle...
46 CFR 4.06-40 - Specimen handling and shipping.
Code of Federal Regulations, 2013 CFR
2013-10-01
...-four (24) hours of receipt by the carrier. (b) The marine employer shall ensure that the urine specimen..., subpart D, are complied with. The marine employer shall ensure that urine specimens required by §§ 4.06-20.... Urine specimens must be shipped by an expeditious means, but need not be shipped in a cooled condition...
49 CFR 40.71 - How does the collector prepare the specimens?
Code of Federal Regulations, 2013 CFR
2013-10-01
... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.71 How does the... brings the urine specimen to you. You must take these steps in the presence of the employee. (1) Check... employee, must first pour at least 30 mL of urine from the collection container into one specimen bottle...
46 CFR 4.06-40 - Specimen handling and shipping.
Code of Federal Regulations, 2011 CFR
2011-10-01
...-four (24) hours of receipt by the carrier. (b) The marine employer shall ensure that the urine specimen..., subpart D, are complied with. The marine employer shall ensure that urine specimens required by §§ 4.06-20.... Urine specimens must be shipped by an expeditious means, but need not be shipped in a cooled condition...
Code of Federal Regulations, 2011 CFR
2011-10-01
... collection process before the employee provides a urine specimen? 40.63 Section 40.63 Transportation Office... PROGRAMS Urine Specimen Collections § 40.63 What steps does the collector take in the collection process before the employee provides a urine specimen? As the collector, you must take the following steps before...
Code of Federal Regulations, 2013 CFR
2013-10-01
... collection process before the employee provides a urine specimen? 40.63 Section 40.63 Transportation Office... PROGRAMS Urine Specimen Collections § 40.63 What steps does the collector take in the collection process before the employee provides a urine specimen? As the collector, you must take the following steps before...
Code of Federal Regulations, 2014 CFR
2014-10-01
... collection process before the employee provides a urine specimen? 40.63 Section 40.63 Transportation Office... PROGRAMS Urine Specimen Collections § 40.63 What steps does the collector take in the collection process before the employee provides a urine specimen? As the collector, you must take the following steps before...
Code of Federal Regulations, 2012 CFR
2012-10-01
... collection process before the employee provides a urine specimen? 40.63 Section 40.63 Transportation Office... PROGRAMS Urine Specimen Collections § 40.63 What steps does the collector take in the collection process before the employee provides a urine specimen? As the collector, you must take the following steps before...
Postal urine specimens: are they a feasible method for genital chlamydial infection screening?
Macleod, J; Rowsell, R; Horner, P; Crowley, T; Caul, E O; Low, N; Smith, G D
1999-01-01
BACKGROUND: A United Kingdom (UK) screening programme for Chlamydia trachomatis has recently been announced. Pilot projects involving the opportunistic testing of women attending health facilities are due to commence in several sites. There is a danger that this approach will fail to obtain adequate population coverage. The alternative--true systematic population screening--is generally assumed to be unfeasible. Studies in Denmark using postal urine specimens have challenged this assumption. No such studies have been reported from the UK. AIM: To assess the potential of urine specimens sent by post as the basis for a UK population screening strategy for genital chlamydial infection. METHOD: Two hundred patients (100 men, 100 women) aged 18 to 45 years were randomly sampled from the list of one urban group practice. Subjects were mailed an explanatory letter, a urine sample container, a sexual lifestyle questionnaire, and a prepaid return envelope. Non-responders were contacted by telephone; persistent non-responders were visited at home. Samples were tested for Chlamydia by DNA amplification and enzyme immunoassay. RESULTS: Sixty-four (32%) subjects were no longer living at their GP registered address. Of the remaining 136, 126 (93%) responded to the survey and 113 (83%) accepted the request for a urine sample and completed a questionnaire. Acceptance rates were similar for men and women and across age groups. Four samples (3%) were Chlamydia positive. CONCLUSION: Home mailed urine specimen collection in conjunction with a self-completed postal questionnaire is feasible. This could provide a viable basis both for determining population Chlamydia prevalence and for a UK Chlamydia population screening strategy. Overall cost effectiveness of such a strategy will depend on the cost of the test used. Comparative performance characteristics of the different currently available tests in this setting have yet to be fully determined. PMID:10562745
Castaneto, Marisol S.; Scheidweiler, Karl B.; Gandhi, Adarsh; Wohlfarth, Ariane; Klette, Kevin L.; Martin, Thomas M.; Huestis, Marilyn A.
2014-01-01
Synthetic cannabinoid intake is an ongoing health issue worldwide, with new compounds continually emerging, making drug testing complex. Parent synthetic cannabinoids are rarely detected in urine, the most common matrix employed in workplace drug testing. Optimal identification of synthetic cannabinoid markers in authentic urine specimens and correlation of metabolite concentrations and toxicities would improve synthetic cannabinoid result interpretation. We screened 20,017 randomly collected US military urine specimens between July 2011 and June 2012 with a synthetic cannabinoid immunoassay yielding 1,432 presumptive positive specimens. We analyzed all presumptive positive and 1,069 negative specimens with our qualitative synthetic cannabinoid LC-MS/MS method, which confirmed 290 positive specimens. All 290 positive and 487 randomly-selected negative specimens were quantified with the most comprehensive urine quantitative LC-MS/MS method published to date. 290 specimens confirmed positive for 22 metabolites from 11 parent synthetic cannabinoids. The five most predominant metabolites were JWH-018 pentanoic acid (93%), JWH-018 N-hydroxypentyl (84%), AM2201 N-hydroxypentyl (69%), JWH-073 butanoic acid (69%), and JWH-122 N-hydroxypentyl (45%) with 11.1 (0.1–2434), 5.1 (0.1–1239), 2.0 (0.1–321), 1.1 (0.1–48.6), and 1.1 (0.1–250) μg/L median (range) concentrations, respectively. Alkyl hydroxy and carboxy metabolites provided suitable biomarkers for 11 parent synthetic cannabinoids; although, hydroxyindoles also were observed. This is by far the largest data set of synthetic cannabinoid metabolites urine concentrations from randomly collected workplace drug testing specimens rather than acute intoxications or driving under the influence of drugs. These data improve the interpretation of synthetic cannabinoid urine test results and suggest suitable urine markers of synthetic cannabinoid intake. PMID:25231213
Confirmation of the Department of Transportation criteria for a substituted urine specimen.
Barbanel, Cheryl S; Winkelman, James W; Fischer, George A; King, Andrew J
2002-05-01
The purpose of this study was to determine whether people could naturally produce urine sufficiently dilute to meet the federal criteria for a "substituted" specimen. The United States Department of Transportation Regulations (49 Code of Federal Regulations Part 40) defines a urine specimen as substituted if it has a creatinine concentration of < or = 5 mg/dL and a specific gravity of < or = 1.001 or > or = 1.020. These criteria have been criticized based on the contention that an insufficient number of specimens had been tested from the same urine sample for both creatinine and specific gravity measurements. We reviewed the results of 803,130 random urine specimens measured for creatinine and/or specific gravity in a hospital-based laboratory. In this database, 13,467 urine specimens had both creatinine and specific gravity measurements. None of these 13,467 paired urine specimens met the lower limit of specific gravity (< or = 1.001) and creatinine (< or = 5 mg/dL) criteria for a Department of Transportation substituted specimen. We also examined the medical records of those patients meeting even one of the two criteria; creatinine concentration < or = 5 mg/dL or specific gravity < or = 1.001. These patients were neonatal, moribund, or so severely ill that essentially none could have been among the working population. These data in patients with various pathologic states support our belief that normal individuals do not produce urine dilute enough to meet the lower limit of the specific gravity (< or = 1.001) and creatinine (< or = 5 mg/dL) required for meeting substituted specimen criteria. Eleven patients met the criteria for a substituted specimen, with elevated specific gravity of > or = 1.020 and creatinine concentration of < or = 5 mg/dL; however, these patients were seriously ill or terminally ill.
VandenBussche, Christopher J; Rosenthal, Dorothy L; Olson, Matthew T
2016-03-01
Adequacy assessment is one of the most controversial and overlooked components in the daily practice of cytopathology, because it is generally determined from limited samples. Because voided urine varies widely in terms of its volume and cellularity, there is little consensus about the proper role for these variables in assessing specimen adequacy. In this study, the authors explored the role of volume in voided urine specimens to determine whether it plays a role in determining adequacy for the detection of high-grade urothelial carcinoma. Voided urine specimens received at the authors' laboratory over the 9.5 years since the introduction of the Johns Hopkins Template for Reporting Urinary Cytopathology were analyzed for correlations between volume, specimen adequacy, and the diagnosis of high-grade malignancy. The same data set also was queried to determine whether a patient who provided a voided low-volume specimen could yield a higher volume specimen and thereby increase adequacy. In total, 15,731 voided urine specimens with a cumulative volume of 891 liters originating from 8594 individual patients were analyzed. Specimen adequacy increased linearly for each increment of volume submitted to the laboratory up to 30 mL, after which the correlation was nonlinear. Low-volume specimens below this cutoff also had lower fractions of specimens that were diagnosed as malignant or suspicious. Volume is an important component in the evaluation of adequacy for voided urine cytology specimens. © 2015 American Cancer Society.
Gorbachinsky, Ilya; Sherertz, Robert; Russell, Gregory; Krane, L Spencer; Hodges, Steve J
2014-12-01
Vulvovaginitis has a known association with urinary tract infections (UTIs) in girls. We hypothesize that vulvovaginitis is a major contributor to UTIs in prepubertal girls by increasing periurethral colonization with uropathogens. Periurethral swabs and urine specimens were obtained from a total of 101 girls (58 with vulvovaginitis and 43 without vulvovaginitis). Specimens were cultured for bacterial growth. The dominant organism in the periurethral swabs and urine cultures was recorded and antibiotic sensitivity profiles were compared. Periurethral swabs from children with vulvovaginitis were associated with a statistically significant increase in uropathogenic bacteria (79% Enterococcus species or Escherichia coli) as the dominant culture compared with swabs from girls without vaginitis (18%) (p < 0.05). In children with vulvovaginitis, 52% of the urine cultures were positive for UTIs, and the dominant organism in the urine cultures matched the species and antibiotic sensitivity profile of the corresponding periurethral swab. Only 11% of the urine cultures from girls without vulvovaginitis were positive for UTIs. Vulvovaginitis may cause UTIs by altering the perineal biome such that there is increased colonization of uropathogens.
Gorbachinsky, Ilya; Sherertz, Robert; Russell, Gregory; Krane, L Spencer
2014-01-01
Background: Vulvovaginitis has a known association with urinary tract infections (UTIs) in girls. We hypothesize that vulvovaginitis is a major contributor to UTIs in prepubertal girls by increasing periurethral colonization with uropathogens. Methods: Periurethral swabs and urine specimens were obtained from a total of 101 girls (58 with vulvovaginitis and 43 without vulvovaginitis). Specimens were cultured for bacterial growth. The dominant organism in the periurethral swabs and urine cultures was recorded and antibiotic sensitivity profiles were compared. Results: Periurethral swabs from children with vulvovaginitis were associated with a statistically significant increase in uropathogenic bacteria (79% Enterococcus species or Escherichia coli) as the dominant culture compared with swabs from girls without vaginitis (18%) (p < 0.05). In children with vulvovaginitis, 52% of the urine cultures were positive for UTIs, and the dominant organism in the urine cultures matched the species and antibiotic sensitivity profile of the corresponding periurethral swab. Only 11% of the urine cultures from girls without vulvovaginitis were positive for UTIs. Conclusions: Vulvovaginitis may cause UTIs by altering the perineal biome such that there is increased colonization of uropathogens. PMID:25435916
10 CFR 26.109 - Urine specimen quantity.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Urine specimen quantity. 26.109 Section 26.109 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.109 Urine... shall encourage the donor to drink a reasonable amount of liquid (normally, 8 ounces of water every 30...
10 CFR 26.109 - Urine specimen quantity.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Urine specimen quantity. 26.109 Section 26.109 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.109 Urine... shall encourage the donor to drink a reasonable amount of liquid (normally, 8 ounces of water every 30...
10 CFR 26.109 - Urine specimen quantity.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Urine specimen quantity. 26.109 Section 26.109 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.109 Urine... shall encourage the donor to drink a reasonable amount of liquid (normally, 8 ounces of water every 30...
Nickel, J Curtis; Stephens, Alisa; Landis, J Richard; Chen, Jun; Mullins, Chris; van Bokhoven, Adrie; Lucia, M Scott; Melton-Kreft, Rachael; Ehrlich, Garth D
2015-07-01
We used next-generation, state-of-the-art, culture independent methodology to survey urine microbiota of males with urologic chronic pelvic pain syndrome and control participants enrolled in the MAPP Network to investigate a possible microbial etiology. Male patients with urologic chronic pelvic pain syndrome and matched controls were asked to provide initial, midstream and post-prostatic massage urine specimens. Specimens were analyzed with Ibis T-5000 Universal Biosensor technology to provide comprehensive identification of bacterial and select fungal species. Differences between urologic chronic pelvic pain syndrome and control study participants for the presence of species or species variation in a higher taxonomic grouping (genus) were evaluated using permutational multivariate analysis of variance and logistic regression. Initial and midstream urine specimens were obtained from 110 (post-prostatic massage urine in 67) participants with urologic chronic pelvic pain syndrome and 115 (post-prostatic massage urine in 62) controls. Overall 78, 73 and 54 species (42, 39 and 27 genera) were detected in initial, midstream and post-prostatic massage urine specimens, respectively. Mean (SD) initial, midstream and post-prostatic massage urine species count per person was 1.62 (1.28), 1.38 (1.36) and 1.33 (1.24) for cases, and 1.75 (1.32), 1.23 (1.15) and 1.56 (0.97) for controls, respectively. Overall species and genus composition differed significantly between participants with urologic chronic pelvic pain syndrome and controls in initial stream urine (p=0.002 species level, p=0.004 genus level), with Burkholderia cenocepacia overrepresented in urologic chronic pelvic pain syndrome. No significant differences were observed at any level in midstream or post-prostatic massage urine samples. Assessment of baseline culture-independent microbiological data from male subjects enrolled in the MAPP Network has identified overrepresentation of B. cenocepacia in urologic chronic pelvic pain syndrome. Future studies are planned to further evaluate microbiota associations with variable and changing urologic chronic pelvic pain syndrome symptom patterns. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Anti-microbial Activity of Urine after Ingestion of Cranberry: A Pilot Study.
Lee, Yee Lean; Najm, Wadie I; Owens, John; Thrupp, Laurie; Baron, Sheryl; Shanbrom, Edward; Cesario, Thomas
2010-06-01
We explore the anti-microbial activity of urine specimens after the ingestion of a commercial cranberry preparation. Twenty subjects without urinary infection, off antibiotics and all supplements or vitamins were recruited. The study was conducted in two phases: in phase 1, subjects collected the first morning urine prior to ingesting 900 mg of cranberry and then at 2, 4 and 6 h. In phase 2, subjects collected urine on 2 consecutive days: on Day 1 no cranberry was ingested (control specimens), on Day 2, cranberry was ingested. The pH of all urine specimens were adjusted to the same pH as that of the first morning urine specimen. Aliquots of each specimen were independently inoculated with Escherichia coli, Klebsiella pneumoniae or Candida albicans. After incubation, colony forming units/ml (CFU ml(-1)) in the control specimen was compared with CFU ml(-1) in specimens collected 2, 4 and 6 h later. Specimens showing ≥50% reduction in CFU ml(-1) were considered as having 'activity' against the strains tested. In phase 1, 7/20 (35%) subjects had anti-microbial activity against E. coli, 13/20 (65%) against K. pneumoniae and 9/20 (45%) against C. albicans in specimens collected 2-6 h after ingestion of cranberry. In phase 2, 6/9 (67%) of the subjects had activity against K. pneumoniae. This pilot study demonstrates weak anti-microbial activity in urine specimens after ingestion of a single dose of commercial cranberry. Anti-microbial activity was noted only against K. pneumoniae 2-6 h after ingestion of the cranberry preparation.
Robandt, P V; Bui, H M; Scancella, J M; Klette, K L
2010-10-01
An automated solid-phase extraction-liquid chromatography- tandem mass spectrometry (SPE-LC-MS-MS) method using the Spark Holland Symbiosis Pharma SPE-LC coupled to a Waters Quattro Micro MS-MS was developed for the analysis of 6-acetylmorphine (6-AM) in human urine specimens. The method was linear (R² = 0.9983) to 100 ng/mL, with no carryover at 200 ng/mL. Limits of quantification and detection were found to be 2 ng/mL. Interrun precision calculated as percent coefficient of variation (%CV) and evaluated by analyzing five specimens at 10 ng/mL over nine batches (n = 45) was 3.6%. Intrarun precision evaluated from 0 to 100 ng/mL ranged from 1.0 to 4.4%CV. Other opioids (codeine, morphine, oxycodone, oxymorphone, hydromorphone, hydrocodone, and norcodeine) did not interfere in the detection, quantification, or chromatography of 6-AM or the deuterated internal standard. The quantified values for 41 authentic human urine specimens previously found to contain 6-AM by a validated gas chromatography (GC)-MS method were compared to those obtained by the SPE-LC-MS-MS method. The SPE-LC-MS-MS procedure eliminates the human factors of specimen handling, extraction, and derivatization, thereby reducing labor costs and rework resulting from human error or technique issues. The time required for extraction and analysis was reduced by approximately 50% when compared to a validated 6-AM procedure using manual SPE and GC-MS analysis.
Hanley, Kevin W.; Petersen, Martin R.; Cheever, Kenneth L.; Luo, Lian
2009-01-01
1-Bromopropane (1-BP) has been marketed as an alternative for ozone depleting and other solvents; it is used in aerosol products, adhesives, metal, precision, and electronics cleaning solvents. Mechanisms of toxicity of 1-BP are not fully understood, but it may be a neurological and reproductive toxicant. Sparse exposure information prompted this study using 1-BP air sampling and urinary metabolites. Mercapturic acid conjugates are excreted in urine from 1-BP metabolism involving debromination. Research objectives were to evaluate the utility of urinary N-acetyl-S-(n-propyl)-L-cysteine (AcPrCys) for assessing exposure to 1-BP and compare it to urinary bromide [Br(−)] previously reported for these workers. Forty-eight-hour urine specimens were obtained from 30 workers at two factories where 1-BP spray adhesives were used to construct polyurethane foam seat cushions. Urine specimens were also obtained from 21 unexposed control subjects. All the workers' urine was collected into composite samples representing three time intervals: at work, after work but before bedtime, and upon awakening. Time-weighted average (TWA) geometric mean breathing zone concentrations were 92.4 and 10.5 p.p.m. for spraying and non-spraying jobs, respectively. Urinary AcPrCys showed the same trend as TWA exposures to 1-BP: higher levels were observed for sprayers. Associations of AcPrCys concentrations, adjusted for creatinine, with 1-BP TWA exposure were statistically significant for both sprayers (P < 0.05) and non-sprayers (P < 0.01). Spearman correlation coefficients for AcPrCys and Br(−) analyses determined from the same urine specimens were highly correlated (P < 0.0001). This study confirms that urinary AcPrCys is an important 1-BP metabolite and an effective biomarker for highly exposed foam cushion workers. PMID:19706636
Flow meter urine testing: a practical proposition in patients attending for urodynamics?
Hashim, Hashim; Abrams, Paul
2006-05-01
To find a practical way of detecting urinary tract infection (UTI) before invasive urodynamic testing, as UTIs after urodynamics are well documented, but there are no standard guidelines about when urine should be analysed before urodynamics. Before urodynamics all patients are asked to provide a free urine flow; the patient is then catheterized to obtain a catheter-specimen of urine that is tested for infection by a urine dipstick. If the dipstick is found positive for nitrites and/or leukocytes, the test is abandoned and the sample sent for microscopy, culture and sensitivity. In the present study, patients were asked to provide a free urine flow into the flowmeter as usual. Between patients, the flowmeter was washed with soap and water and dried, so that there would be no cross-contamination between patients' urine results. Urine was collected as usual and tested using a dipstick, the patient was then catheterized and another dipstick test done on the catheter specimen of urine (CSU), to compare results. Pairs of urine samples, when positive for nitrite were 100% consistent, and 89% of pairs positive for leukocytes were the same before and after catheterization. The remaining 11% (all women) of the positive leukocyte group had leukocytosis on testing the flowmeter urine but not on the CSU, possibly due to contamination from the vagina. Testing urine by dipstick in the sample from the flowmeter is a feasible option, thus saving the patient an inappropriate catheterization, with the risk of bacteraemia during urodynamics, and allowing the flowrate to be measured.
Castaneto, Marisol S; Scheidweiler, Karl B; Gandhi, Adarsh; Wohlfarth, Ariane; Klette, Kevin L; Martin, Thomas M; Huestis, Marilyn A
2015-06-01
Synthetic cannabinoid intake is an ongoing health issue worldwide, with new compounds continually emerging, making drug testing complex. Parent synthetic cannabinoids are rarely detected in urine, the most common matrix employed in workplace drug testing. Optimal identification of synthetic cannabinoid markers in authentic urine specimens and correlation of metabolite concentrations and toxicities would improve synthetic cannabinoid result interpretation. We screened 20 017 randomly collected US military urine specimens between July 2011 and June 2012 with a synthetic cannabinoid immunoassay yielding 1432 presumptive positive specimens. We analyzed all presumptive positive and 1069 negative specimens with our qualitative synthetic cannabinoid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method, which confirmed 290 positive specimens. All 290 positive and 487 randomly selected negative specimens were quantified with the most comprehensive urine quantitative LC-MS/MS method published to date; 290 specimens confirmed positive for 22 metabolites from 11 parent synthetic cannabinoids. The five most predominant metabolites were JWH-018 pentanoic acid (93%), JWH-N-hydroxypentyl (84%), AM2201 N-hydroxypentyl (69%), JWH-073 butanoic acid (69%), and JWH-122 N-hydroxypentyl (45%) with 11.1 (0.1-2,434), 5.1 (0.1-1,239), 2.0 (0.1-321), 1.1 (0.1-48.6), and 1.1 (0.1-250) µg/L median (range) concentrations, respectively. Alkyl hydroxy and carboxy metabolites provided suitable biomarkers for 11 parent synthetic cannabinoids; although hydroxyindoles were also observed. This is by far the largest data set of synthetic cannabinoid metabolites urine concentrations from randomly collected workplace drug testing specimens rather than acute intoxications or driving under the influence of drugs. These data improve the interpretation of synthetic cannabinoid urine test results and suggest suitable urine markers of synthetic cannabinoid intake. This article is a U.S. Government work and is in the public domain in the USA.
Use of a midstream clean catch mobile application did not lower urine contamination rates in an ED.
Jacob, Mary S; Kulie, Paige; Benedict, Cameron; Ordoobadi, Alexander J; Sikka, Neal; Steinmetz, Erika; McCarthy, Melissa L
2018-01-01
Urine microscopy is a common test performed in emergency departments (EDs). Urine specimens can easily become contaminated by different factors, including the collection method. The midstream clean-catch (MSCC) collection technique is commonly used to reduce urine contamination. The urine culture contamination rate from specimens collected in our ED is 30%. We developed an instructional application (app) to show ED patients how to provide a MSCC urine sample. We hypothesized that ED patients who viewed our instructional app would have significantly lower urine contamination rates compared to patients who did not. We prospectively enrolled 257 subjects with a urinalysis and/or urine culture test ordered in the ED and asked them to watch our MSCC instructional app. After prospective enrollment was complete, we retrospectively matched each enrolled subject to an ED patient who did not watch the instructional app. Controls were matched to cases based on gender, type of urine specimen provided, ED visit date and shift. Urinalysis and urine culture contamination results were compared between the matched pairs using McNemar's test. The overall urine culture contamination rate of the 514 subjects was 38%. The majority of the matched pairs had a urinalysis (63%) or urinalysis plus urine culture (35%) test done. There were no significant differences in our urine contamination rates between the matched pairs overall or when stratified by gender, by prior knowledge of the clean catch process or by type of urine specimen. We did not see a lower contamination rate for patients who viewed our instructional app compared to patients who did not. It is possible that MSCC is not effective for decreasing urine specimen contamination. Copyright © 2017 Elsevier Inc. All rights reserved.
Dede, Gülay; Deveci, Özcan; Dede, Onur; Utanğac, Mazhar; Dağgulli, Mansur; Penbegül, Necmettin; Hatipoğlu, Namık Kemal
2016-12-01
The aim of this study was to compare the results of urine cultures obtained either from urethral, and percutaneous nephrostomy (PCN) catheters. This study included 328 consecutive patients that underwent PCN at our institution with complicated urinary tract infections (UTIs) between July 2010 and April 2015. Results of urine cultures obtained from the urethral and nephrostomy catheters were compared. This study included 152 male and 176 female patients. Mean age of the patients was 46.2±24.3 years. The main indications were obstructive uropathy due to urolithiasis complicated with pyonephrosis 145 (44%), malignant disease (n=87; 26%), pregnancy (n=26; 8%), and anatomical abnormality (n=23; 7%). One hundred and twenty three patients had diabetes mellitus. The most common causative organisms were Escherichia coli , Klebsiella pneumoniae , and Pseudomonas aeruginosa . Blood cultures showed the same results for the PCN and bladder urine cultures. The bladder urine culture was positive in 304 patients, while the PCN urine culture in 314 patients. PCN is an important treatment for the management of pyonephrosis. Cultures from the PCN yield valuable information that is not available from urethral urine cultures, and is a guiding tool for antibiotic therapy selection.
Bertholf, Roger L; Johannsen, Laura M; Reisfield, Gary M
2015-01-01
Urine drug testing (UDT) is an emerging standard of care in the evaluation and treatment of chronic non-cancer pain patients with opioid analgesics. UDT may be used both to verify adherence with the opioid analgesic regimen and to monitor abstinence from non-prescribed or illicit controlled substances. In the former scenario, it is vital to determine whether the drug is present in the urine, even at low concentrations, because failure to detect the drug may lead to accusations of opioid abuse or diversion. Opiate immunoassays typically are developed to detect morphine and are most sensitive to morphine and codeine. Although many opiate immunoassays also detect hydrocodone (HC) and/or hydromorphone (HM), sensitivities for these analytes are often much lower, increasing the possibility of negative screening results when the drug is present in the urine. We selected 112 urine specimens from patients who had been prescribed HC or hydromorphone but were presumptive negative by the Roche Online DAT Opiate II™ urine drug screening assay, which is calibrated to 300 ng/mL morphine. Using a GC/MS confirmatory method with a detection limit of 50 ng/mL both for HC and for HM, one or both of these opiates were detected in 81 (72.3%) of the urine specimens. Examination of the raw data from these presumptive negative opiate screens revealed that, in many cases, the turbidity signal was greater than the signal obtained for the negative control, but less than the signal for the 300 ng/mL (morphine) threshold calibrator. A receiver operating characteristic curve generated for the reciprocal of the ratio of turbidity measurements in the patient specimens and negative (drug-free) controls, against the presence or absence of HC and/or HM by confirmatory analyses, produced an area under the curve of 0.910. We conclude that this opiate immunoassay has sufficient sensitivity to detect HC and/or HM in some urine specimens that screen presumptive negative for these commonly prescribed opiates at the established threshold. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Urine culture contamination: a College of American Pathologists Q-Probes study of 127 laboratories.
Bekeris, Leonas G; Jones, Bruce Allen; Walsh, Molly K; Wagar, Elizabeth A
2008-06-01
While urine culture contamination may not be completely avoidable, some laboratories have lower contamination rates than others. A College of American Pathologists (CAP) 1998 Q-Probes study showed that many interventions commonly assumed to reduce contamination were not demonstrably effective. This article revisits the issue. To examine the frequency of urine culture contamination, review current laboratory practices in the collection of urine culture specimens, and determine practice characteristics that may be associated with the contamination rate. Laboratories participating in a CAP Q-Probes study were required to prospectively collect data on 120 consecutive urine culture specimens and provide information on the patient's demographics (age and sex), the location where the specimen was collected, how the specimen was handled, the number of isolates in quantities greater than or equal to 10,000 colony-forming units (CFU)/mL, and whether the laboratory considered the specimen to be contaminated. Specific inclusion and exclusion criteria were provided to the participants. Each laboratory completed a supplemental questionnaire that probed for specific laboratory urine culture collection practices. One hundred twenty-seven laboratories participated in the study. Results from a total of 14,739 urine specimens were received. For the purpose of this study, a urine specimen was determined to be contaminated if the culture yielded more than 2 isolates in quantities greater than or equal to 10,000 CFU/mL. Using these criteria the median institution had a contamination rate of 15.0%. Laboratories in the 10th percentile (low performance) had an average contamination rate of 41.7%, while laboratories in the 90th percentile had an average rate of 0.8%. The collection site had no influence on the contamination rate, but postcollection processing, especially refrigeration of the specimen, had a substantial effect. Providing instruction to patients produced a statistically significant lowering of contamination rates for specimens from male patients (P = .006) but not for female patients, except when written instructions were provided in the emergency room, in which case specimen contamination rates for both male and female patients dropped (P = .01). The median contamination rates remain at a level comparable to the results seen in a previous Q-Probes study, and some laboratories have very high contamination rates. Specimen refrigeration is associated with lower overall urine culture specimen contamination rate. Providing patient instruction is also associated with lower contamination rates under specific circumstances.
49 CFR 40.65 - What does the collector check for when the employee presents a specimen?
Code of Federal Regulations, 2013 CFR
2013-10-01
... PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.65.... You must check to ensure that the specimen contains at least 45 mL of urine. (1) If it does not, you... of tampering) also exists. (3) You are never permitted to combine urine collected from separate voids...
49 CFR 40.65 - What does the collector check for when the employee presents a specimen?
Code of Federal Regulations, 2011 CFR
2011-10-01
... PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.65.... You must check to ensure that the specimen contains at least 45 mL of urine. (1) If it does not, you... of tampering) also exists. (3) You are never permitted to combine urine collected from separate voids...
49 CFR 40.65 - What does the collector check for when the employee presents a specimen?
Code of Federal Regulations, 2010 CFR
2010-10-01
... PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.65.... You must check to ensure that the specimen contains at least 45 mL of urine. (1) If it does not, you... of tampering) also exists. (3) You are never permitted to combine urine collected from separate voids...
49 CFR 40.65 - What does the collector check for when the employee presents a specimen?
Code of Federal Regulations, 2014 CFR
2014-10-01
... PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.65.... You must check to ensure that the specimen contains at least 45 mL of urine. (1) If it does not, you... of tampering) also exists. (3) You are never permitted to combine urine collected from separate voids...
49 CFR 40.65 - What does the collector check for when the employee presents a specimen?
Code of Federal Regulations, 2012 CFR
2012-10-01
... PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.65.... You must check to ensure that the specimen contains at least 45 mL of urine. (1) If it does not, you... of tampering) also exists. (3) You are never permitted to combine urine collected from separate voids...
Code of Federal Regulations, 2010 CFR
2010-01-01
... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...
Code of Federal Regulations, 2013 CFR
2013-01-01
... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...
Code of Federal Regulations, 2014 CFR
2014-01-01
... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...
Code of Federal Regulations, 2012 CFR
2012-01-01
... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...
Code of Federal Regulations, 2011 CFR
2011-01-01
... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...
10 CFR 26.111 - Checking the acceptability of the urine specimen.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Checking the acceptability of the urine specimen. 26.111 Section 26.111 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for..., the collector shall measure the temperature of the specimen. The temperature-measuring device used...
10 CFR 26.111 - Checking the acceptability of the urine specimen.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Checking the acceptability of the urine specimen. 26.111 Section 26.111 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for..., the collector shall measure the temperature of the specimen. The temperature-measuring device used...
10 CFR 26.111 - Checking the acceptability of the urine specimen.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Checking the acceptability of the urine specimen. 26.111 Section 26.111 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for..., the collector shall measure the temperature of the specimen. The temperature-measuring device used...
Franek, Jacob; Leibach, Elizabeth K.; Weissfeld, Alice S.; Kraft, Colleen S.; Sautter, Robert L.; Baselski, Vickie; Rodahl, Debra; Peterson, Edward J.; Cornish, Nancy E.
2015-01-01
SUMMARY Background. Urinary tract infection (UTI) in the United States is the most common bacterial infection, and urine cultures often make up the largest portion of workload for a hospital-based microbiology laboratory. Appropriately managing the factors affecting the preanalytic phase of urine culture contributes significantly to the generation of meaningful culture results that ultimately affect patient diagnosis and management. Urine culture contamination can be reduced with proper techniques for urine collection, preservation, storage, and transport, the major factors affecting the preanalytic phase of urine culture. Objectives. The purposes of this review were to identify and evaluate preanalytic practices associated with urine specimens and to assess their impact on the accuracy of urine culture microbiology. Specific practices included collection methods for men, women, and children; preservation of urine samples in boric acid solutions; and the effect of refrigeration on stored urine. Practice efficacy and effectiveness were measured by two parameters: reduction of urine culture contamination and increased accuracy of patient diagnosis. The CDC Laboratory Medicine Best Practices (LMBP) initiative's systematic review method for assessment of quality improvement (QI) practices was employed. Results were then translated into evidence-based practice guidelines. Search strategy. A search of three electronic bibliographic databases (PubMed, SCOPUS, and CINAHL), as well as hand searching of bibliographies from relevant information sources, for English-language articles published between 1965 and 2014 was conducted. Selection criteria. The search contained the following medical subject headings and key text words: urinary tract infections, UTI, urine/analysis, urine/microbiology, urinalysis, specimen handling, preservation, biological, preservation, boric acid, boric acid/borate, refrigeration, storage, time factors, transportation, transport time, time delay, time factor, timing, urine specimen collection, catheters, indwelling, urinary reservoirs, continent, urinary catheterization, intermittent urethral catheterization, clean voided, midstream, Foley, suprapubic, bacteriological techniques, and microbiological techniques. Main results. Both boric acid and refrigeration adequately preserved urine specimens prior to their processing for up to 24 h. Urine held at room temperature for more than 4 h showed overgrowth of both clinically significant and contaminating microorganisms. The overall strength of this body of evidence, however, was rated as low. For urine specimens collected from women, there was no difference in rates of contamination for midstream urine specimens collected with or without cleansing. The overall strength of this evidence was rated as high. The levels of diagnostic accuracy of midstream urine collection with or without cleansing were similar, although the overall strength of this evidence was rated as low. For urine specimens collected from men, there was a reduction in contamination in favor of midstream clean-catch over first-void specimen collection. The strength of this evidence was rated as high. Only one study compared midstream collection with cleansing to midstream collection without cleansing. Results showed no difference in contamination between the two methods of collection. However, imprecision was due largely to the small event size. The diagnostic accuracy of midstream urine collection from men compared to straight catheterization or suprapubic aspiration was high. However, the overall strength of this body of evidence was rated as low. For urine specimens collected from children and infants, the evidence comparing contamination rates for midstream urine collection with cleansing, midstream collection without cleansing, sterile urine bag collection, and diaper collection pointed to larger reductions in the odds of contamination in favor of midstream collection with cleansing over the other methods of collection. This body of evidence was rated as high. The accuracy of diagnosis of urinary tract infection from midstream clean-catch urine specimens, sterile urine bag specimens, or diaper specimens compared to straight catheterization or suprapubic aspiration was varied. Authors' conclusions. No recommendation for or against is made for delayed processing of urine stored at room temperature, refrigerated, or preserved in boric acid. This does not preclude the use of refrigeration or chemical preservatives in clinical practice. It does indicate, however, that more systematic studies evaluating the utility of these measures are needed. If noninvasive collection is being considered for women, midstream collection with cleansing is recommended, but no recommendation for or against is made for midstream collection without cleansing. If noninvasive collection is being considered for men, midstream collection with cleansing is recommended and collection of first-void urine is not recommended. No recommendation for or against is made for collection of midstream urine without cleansing. If noninvasive collection is being considered for children, midstream collection with cleansing is recommended and collection in sterile urine bags, from diapers, or midstream without cleansing is not recommended. Whether midstream collection with cleansing can be routinely used in place of catheterization or suprapubic aspiration is unclear. The data suggest that midstream collection with cleansing is accurate for the diagnosis of urinary tract infections in infants and children and has higher average accuracy than sterile urine bag collection (data for diaper collection were lacking); however, the overall strength of evidence was low, as multivariate modeling could not be performed, and thus no recommendation for or against can be made. PMID:26598386
DOT National Transportation Integrated Search
1996-05-01
This paper describes a new single extraction screening procedure that was developed to identify as many drugs as possible in urine, with minimal effort and cost. Urine specimens are hydrolyzed and the specimen is then extracted using commercially pur...
Effect of storage temperature on endogenous GHB levels in urine.
LeBeau, M A; Miller, M L; Levine, B
2001-06-15
Because gamma-hydroxybutyrate (GHB) is an endogenous substance present in the body and is rapidly eliminated after ingestion, toxicologists investigating drug-facilitated sexual assault cases are often asked to differentiate between endogenous and exogenous levels of GHB in urine samples. This study was designed to determine the effects of storage temperature on endogenous GHB levels in urine. Specifically, it was designed to ascertain whether endogenous levels can be elevated to a range considered indicative of GHB ingestion. Urine specimens from two subjects that had not been administered exogenous GHB were collected during a 24h period and individually pooled. The pooled specimens were separated into standard sample cups and divided into three storage groups: room temperature ( approximately 25 degrees C), refrigerated (5 degrees C), and frozen (-10 degrees C). Additionally, some specimens were put through numerous freeze/thaw cycles to mimic situations that may occur if multiple laboratories analyze the same specimen. Periodic analysis of the samples revealed increases in the levels of endogenous GHB over a 6-month period. The greatest increase (up to 404%) was observed in the samples maintained at room temperature. The refrigerated specimens showed increases of 140-208%, while the frozen specimens showed smaller changes (88-116%). The specimens subjected to multiple freeze/thaw cycles mirrored specimens that had been thawed only once. None of the stored urine specimens demonstrated increases in GHB concentrations that would be consistent with exogenous GHB ingestion.
Hammerschlag, M R; Roblin, P M; Gelling, M; Tsumura, N; Jule, J E; Kutlin, A
1997-03-01
Chlamydia trachomatis is the most common identifiable infectious cause of neonatal conjunctivitis. Nonculture tests including enzyme immunoassays and direct fluorescent antibody tests have been shown to perform well for the diagnosis of chlamydial conjunctivitis with sensitivities and specificities > or = 90%. However, the performance with respiratory specimens has been less than satisfactory. We compared a new, commercially available polymerase chain reaction (PCR) assay, Roche AMPLICOR (Roche Diagnostic Systems, Branchburg, NJ) with culture for the detection of C. trachomatis in conjunctival and nasopharyngeal specimens from infants with conjunctivitis. We also evaluated AMPLICOR for the detection of C. trachomatis in the urine of mothers of positive infants. Ocular and nasopharyngeal specimens from 75 infants with conjunctivitis were obtained for culture and PCR. AMPLICOR was equivalent to culture for eye specimens and more sensitive than culture for nasopharyngeal specimens. The sensitivity, specificity and positive and negative predictive values of PCR compared with culture for conjunctival specimens were 92.3, 100, 100 and 98.4%, respectively. The sensitivity, specificity and positive and negative predictive values for nasopharyngeal specimens were 100, 97.2, 60 and 100%, respectively. We also detected C. trachomatis by PCR in the urine of 12 mothers of culture positive infants. PCR performed comparably to culture for detection of C. trachomatis in conjunctival and nasopharyngeal specimens from infants with conjunctivitis.
Voided Midstream Urine Culture and Acute Cystitis in Premenopausal Women
Hooton, Thomas M; Roberts, Pacita L.; Cox, Marsha E.; Stapleton, Ann E.
2014-01-01
BACKGROUND The cause of acute uncomplicated cystitis is determined on the basis of cultures of voided midstream urine, but few data guide the interpretation of such results, especially when gram-positive bacteria grow. METHODS Women from 18 to 49 years of age with symptoms of cystitis provided specimens of midstream urine, after which we collected urine by means of a urethral catheter for culture (catheter urine). We compared microbial species and colony counts in the paired specimens. The primary outcome was a comparison of positive predictive values and negative predictive values of organisms grown in midstream urine, with the presence or absence of the organism in catheter urine used as the reference. RESULTS The analysis of 236 episodes of cystitis in 226 women yielded 202 paired specimens of midstream urine and catheter urine that could be evaluated. Cultures were positive for uropathogens in 142 catheter specimens (70%), 4 of which had more than one uropathogen, and in 157 midstream specimens (78%). The presence of Escherichia coli in midstream urine was highly predictive of bladder bacteriuria even at very low counts, with a positive predictive value of 102 colony-forming units (CFU) per milliliter of 93% (Spearman’s r = 0.944). In contrast, in midstream urine, enterococci (in 10% of cultures) and group B streptococci (in 12% of cultures) were not predictive of bladder bacteriuria at any colony count (Spearman’s r = 0.322 for enterococci and 0.272 for group B streptococci). Among 41 episodes in which enterococcus, group B streptococci, or both were found in midstream urine, E. coli grew from catheter urine cultures in 61%. CONCLUSIONS Cultures of voided midstream urine in healthy premenopausal women with acute uncomplicated cystitis accurately showed evidence of bladder E. coli but not of enterococci or group B streptococci, which are often isolated with E. coli but appear to rarely cause cystitis by themselves. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases.) PMID:24224622
Mass spectrometric detection of peginesatide in human urine in doping control analysis.
Möller, Ines; Thomas, Andreas; Delahaut, Philippe; Geyer, Hans; Schänzer, Wilhelm; Thevis, Mario
2012-11-01
Erythropoiesis-stimulating agents (ESAs) have frequently been confessed to be illicitly used in elite sports due to their endurance enhancing effects. Recently, peginesatide, the first representative of a new generation of ESAs, referred to as Erythropoietin (EPO)-mimetic peptides, obtained approval in the USA under the trade name Omontys(®) for the treatment of anaemic patients. Lacking sequence homology with EPO, it consists of a pegylated homodimeric peptide of approximately 45 kDa, and thus, specific approaches for the determination of peginesatide in blood were developed as conventional detection assays for EPO do not allow for the analysis of the EPO-mimetic peptides. However, as urine specimens are the most frequently provided doping control samples and pharmacokinetic studies conducted in rats and monkeys revealed the excretion of the pegylated peptide into urine, a detection method for peginesatide in urine would be desirable. A mass spectrometric assay in human urine was developed consisting of protein precipitation with acetonitrile followed by proteolytic digestion after the removal of the acetonitrile fraction under reduced pressure. Purification and concentration of the resulting proteotypic target peptide was accomplished by means of solid-phase extraction on strong cation-exchange resin prior to liquid chromatographic-tandem mass spectrometric analysis. Method validation was performed for qualitative purposes and demonstrated specificity, precision, linearity as well as sufficient sensitivity (limit of detection: 0.5 ng/ml) while proof-of-concept for the applicability of the assay for the determination of peginesatide in authentic urine samples was obtained by analyzing animal in vivo specimens collected after a single i.v. administration of peginesatide over a period of 4 days. Copyright © 2012 Elsevier B.V. All rights reserved.
Determinants of practice patterns in pediatric UTI management.
Selekman, R E; Allen, I E; Copp, H L
2016-10-01
Urinary tract infection (UTI) affects 10% of girls and 3% of boys by age 16. Both the American Academy of Pediatrics and National Institute for Health and Clinical Excellence Guidelines recommend urine testing prior to initiation of antibiotic treatment and the use of local antibiograms to guide empiric antibiotic therapy. Urine culture results not only provide the opportunity to halt empiric therapy if there is no bacterial growth, but also allow for tailoring of broad-spectrum therapy. Additionally, the use of antiobiograms improves empiric antibiotic selection based on local resistance patterns. However, execution of guideline recommendations has proved challenging. Understanding barriers in implementation is critical to developing targeted interventions aimed to improve adherence to these guidelines. The present study sought to investigate practice patterns and factors that influence urine testing and antibiogram use in the setting of empiric antibiotic treatment of UTI in children to ultimately improve adherence to UTI management guidelines. A random, national sample of physicians caring for children was surveyed from the American Medical Association Masterfile. Participants were queried regarding practice type, length of time in practice, factors influencing urine testing, urine specimen collection method, and antibiogram utilization. Logistic regression was used to assess factors associated with use of urine testing, bagged specimens, and antibiograms. Of respondents who acknowledged contact by surveyors, 47% completed the survey (n = 366). Most respondents (84%) obtain urinalysis and culture prior to treatment for UTI. Physicians report they would more likely order testing if the specimen were easier to collect (46%) and if results were available immediately (48%) (Table). Urine collection by bag was more common in circumcised boys (>30%) compared with girls (20%) and uncircumcised boys (20%) (P = 0.02). The most common reasons for collection by bag were parental refusal for (49%) and difficulty with (42%) catheterization (Table). Of the 70% of respondents reporting antibiogram access (n = 256), 50% report its use the majority of the time with empiric prescription (n = 128). While most practitioners report following guidelines to obtain urine testing prior to antibiotic prescription for UTI, urine collection by bag is common. Additionally, <50% of practitioners adhere to guideline recommendations for empiric antibiotic selection based on local antibiograms. Interventions to improve adherence to UTI management guidelines should focus on (1) improving catheterization practices, (2) educating parents regarding the value of catheterization, and (3) incorporating local antibiograms into electronic medical records. Copyright © 2016 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
Dasgupta, Amitava; Wahed, Amer; Wells, Alice
2002-02-01
Several adulterants are used to mask tests for abused drugs in urine. Adulterants such as "Klear" and "Whizzies" contain potassium nitrite, and "Urine Luck" contains pyridinium chlorochromate (PCC). The presence of these adulterants cannot be detected by routine specimen integrity checks (pH, specific gravity, and temperature). We developed rapid spot tests for detecting these adulterants in urine. Addition of 3% hydrogen peroxide in urine adulterated with PCC caused rapid formation of a dark brown color. In contrast, unadulterated urine turned colorless when hydrogen peroxide was added. When urine contaminated with nitrite and 2 to 3 drops of 2N hydrochloric acid were added to 2% aqueous potassium permanganate solution, the dark pink permanganate solution turned colorless immediately with effervescence. Urine contaminated with nitrite liberated iodine from potassium iodide solution in the presence of 2N hydrochloric acid. Urine adulterated with PCC also liberated iodine from potassium iodide in acid medium but did not turn potassium permanganate solution colorless. Urine specimens from volunteers and random urine samples that tested negative for drugs did not cause false-positive results. These rapid spot tests are useful for detecting adulterated urine to avoid false-negative drug tests.
49 CFR 40.33 - What training requirements must a collector meet?
Code of Federal Regulations, 2012 CFR
2012-10-01
... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.33 What training... about this part, the current “DOT Urine Specimen Collection Procedures Guidelines,” and DOT agency... changes to these materials. The DOT Urine Specimen Collection Procedures Guidelines document is available...
49 CFR 40.33 - What training requirements must a collector meet?
Code of Federal Regulations, 2013 CFR
2013-10-01
... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.33 What training... about this part, the current “DOT Urine Specimen Collection Procedures Guidelines,” and DOT agency... changes to these materials. The DOT Urine Specimen Collection Procedures Guidelines document is available...
49 CFR 40.33 - What training requirements must a collector meet?
Code of Federal Regulations, 2011 CFR
2011-10-01
... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.33 What training... about this part, the current “DOT Urine Specimen Collection Procedures Guidelines,” and DOT agency... changes to these materials. The DOT Urine Specimen Collection Procedures Guidelines document is available...
49 CFR 40.33 - What training requirements must a collector meet?
Code of Federal Regulations, 2010 CFR
2010-10-01
... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.33 What training... about this part, the current “DOT Urine Specimen Collection Procedures Guidelines,” and DOT agency... changes to these materials. The DOT Urine Specimen Collection Procedures Guidelines document is available...
49 CFR 40.33 - What training requirements must a collector meet?
Code of Federal Regulations, 2014 CFR
2014-10-01
... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.33 What training... about this part, the current “DOT Urine Specimen Collection Procedures Guidelines,” and DOT agency... changes to these materials. The DOT Urine Specimen Collection Procedures Guidelines document is available...
Detection of human papillomavirus DNA in urine. A review of the literature.
Vorsters, A; Micalessi, I; Bilcke, J; Ieven, M; Bogers, J; Van Damme, P
2012-05-01
The detection of human papillomavirus (HPV) DNA in urine, a specimen easily obtained by a non-invasive self-sampling method, has been the subject of a considerable number of studies. This review provides an overview of 41 published studies; assesses how different methods and settings may contribute to the sometimes contradictory outcomes; and discusses the potential relevance of using urine samples in vaccine trials, disease surveillance, epidemiological studies, and specific settings of cervical cancer screening. Urine sampling, storage conditions, sample preparation, DNA extraction, and DNA amplification may all have an important impact on HPV DNA detection and the form of viral DNA that is detected. Possible trends in HPV DNA prevalence in urine could be inferred from the presence of risk factors or the diagnosis of cervical lesions. HPV DNA detection in urine is feasible and may become a useful tool but necessitates further improvement and standardization.
Atypical cells in a voided urine cytology specimen in a renal transplant recipient.
Lu, Miao; Ho, Julie; Azordegan, Nazila; Perry, Anamarija M; Gibson, Ian W; Baker, Patricia
2017-01-01
Voided urine is routinely collected from renal transplant patients to screen for polyomavirus. In rare cases, atypical lymphoid cells can be detected in voided urine and raise the suspicion of post-transplant lymphoproliferative disorder (PTLD). However, further immunohistochemistry of the cell block and flow cytometry is frequently limited by the low cellularity and poor preservation of voided urine. Therefore, PTLD of the renal allograft is usually diagnosed from tissue biopsy or nephrectomy specimens. Herein, we report a rare case of atypical cells in a voided urine cytology specimen from a kidney transplant recipient. Needle core biopsy of the renal allograft showed monomorphic PTLD. Diagn. Cytopathol. 2017;45:69-72. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Bingham, Andrea M; Cone, Marshall; Mock, Valerie; Heberlein-Larson, Lea; Stanek, Danielle; Blackmore, Carina; Likos, Anna
2016-05-13
In May 2015, Zika virus was reported to be circulating in Brazil. This was the first identified introduction of the virus in the Region of the Americas. Since that time, Zika virus has rapidly spread throughout the region. As of April 20, 2016, the Florida Department of Health Bureau of Public Health Laboratories (BPHL) has tested specimens from 913 persons who met state criteria for Zika virus testing. Among these 913 persons, 91 met confirmed or probable Zika virus disease case criteria and all cases were travel-associated (1). On the basis of previous small case studies reporting real time reverse-transcription polymerase chain reaction (RT-PCR) detection of Zika virus RNA in urine, saliva, and semen (2-6), the Florida Department of Health collected multiple specimen types from persons with suspected Zika virus disease. Test results were evaluated by specimen type and number of days after symptom onset to determine the most sensitive and efficient testing algorithm for acute Zika virus disease. Urine specimens were collected from 70 patients with suspected Zika virus disease from zero to 20 days after symptom onset. Of these, 65 (93%) tested positive for Zika virus RNA by RT-PCR. Results for 95% (52/55) of urine specimens collected from persons within 5 days of symptom onset tested positive by RT-PCR; only 56% (31/55) of serum specimens collected on the same date tested positive by RT-PCR. Results for 82% (9/11) of urine specimens collected >5 days after symptom onset tested positive by RT-PCR; none of the RT-PCR tests for serum specimens were positive. No cases had results that were exclusively positive by RT-PCR testing of saliva. BPHL testing results suggest urine might be the preferred specimen type to identify acute Zika virus disease.
Kokoski, R J; Jain, M
1975-03-01
Radioimmunoassay (RIA) and thin-layer chromatography (TLC) were compared for morphine detection in an actual narcotic clinic setting. A choice of urines from all those screened by TLC allowed a critical comparison as to actual use or non-use of narcotic drugs, rather than a sampling at random in which the question of possible false positives or negatives cannot be conclusively answered. Although RIA is more sensitive than TLC, its advantage is apparent only in those cases where urine specimens are difficult to obtain frequently regularly or where the use of morphine is suspected by the positive identification of quinine in urine that was morphine-negative by TLC. In a selected group of negative and positive specimens chosen without conscious bias, the two methods gave consistently similar results, indicating that the modified TLC method provided a few or no false positives or negatives if the negatives were from those cases that were not positive anytime up to 3-4 days before urine collection. We conclude that RIA can be of significant value as a supplement to a TLC screening program, without sacrificing the many advantages that TLC has to offer.
Hillman, R J; Ryait, B K; Botcherby, M; Taylor-Robinson, D
1993-01-01
OBJECTIVE--To assess the presence of human papillomavirus (HPV) DNA in urethral and urine specimens from men with and without sexually transmitted diseases. DESIGN--Prospective study. SETTING--Two London departments of genitourinary medicine PATIENTS--100 men with urethral gonorrhoea, 31 men with penile warts and 37 men with genital dermatoses. METHODS--Urethral and urine specimens were taken, HPV DNA extracted and then amplified using the polymerase chain reaction. HPV types 6, 11, 16, 18, 31 and 33 were identified using Southern blotting followed by hybridisation. RESULTS--HPV DNA was detected in 18-31% of urethral swab specimens and in 0-14% of urine specimens. Men with penile warts had HPV detected in urethral swabs more often than did men in the other two clinical groups. "High risk" HPV types were found in 71-83% of swab specimens and in 73-80% of urine specimens containing HPV DNA. CONCLUSIONS--HPV is present in the urogenital tracts of men with gonorrhoea, penile warts and with genital dermatoses. In men with urethral gonorrhoea, detection of HPV in urethral specimens is not related to the number of sexual partners, condom usage, racial origin or past history of genital warts. HPV DNA in the urethral swab and urine specimens may represent different aspects of the epidemiology of HPV in the male genital tract. The preponderance of HPV types 16 and 18 in all three groups of men may be relevant to the concept of the "high risk male". Images PMID:8392967
Is specific gravity a good estimate of urine osmolality?
Imran, Sethi; Eva, Goldwater; Christopher, Shutty; Flynn, Ethan; Henner, David
2010-01-01
Urine specific gravity (USG) is often used by clinicians to estimate urine osmolality. USG is measured either by refractometry or by reagent strip. We studied the correlation of USG obtained by either method with a concurrently obtained osmolality. Using our laboratory's records, we retrospectively gathered data on 504 urine specimens on patients on whom a simultaneously drawn USG and an osmolality were available. Out of these, 253 USG's were measured by automated refractometry and 251 USG's were measured by reagent strip. Urinalysis data on these subjects were used to determine the correlation between USG and osmolality, adjusting for other variables that may impact the relationship. The other variables considered were pH, protein, glucose, ketones, nitrates, bilirubin, urobilinogen, hemoglobin, and leukocyte esterase. The relationships were analyzed by linear regression. This study demonstrated that USG obtained by both reagent strip and refractometry had a correlation of approximately 0.75 with urine osmolality. The variables affecting the correlation included pH, ketones, bilirubin, urobilinogen, glucose, and protein for the reagent strip and ketones, bilirubin, and hemoglobin for the refractometry method. At a pH of 7 and with an USG of 1.010 predicted osmolality is approximately 300 mosm/kg/H(2)O for either method. For an increase in SG of 0.010, predicted osmolality increases by 182 mosm/kg/H(2) O for the reagent strip and 203 mosm/kg/H(2)O for refractometry. Pathological urines had significantly poorer correlation between USG and osmolality than "clean" urines. In pathological urines, direct measurement of urine osmolality should be used. © 2010 Wiley-Liss, Inc.
Kwok, Janette; Choi, Leo C W; Ho, Jenny C Y; Chan, Gavin S W; Mok, Maggie M Y; Lam, Man-Fei; Chak, Wai-Leung; Cheuk, Au; Chau, Ka-Foon; Tong, Matthew; Chan, Kwok-Wah; Chan, Tak-Mao
2016-01-01
Urine from kidney transplant recipient has proven to be a viable source for donor DNA. However, an optimized protocol would be required to determine mis-matched donor HLA specificities in view of the scarcity of DNA obtained in some cases. In this study, fresh early morning urine specimens were obtained from 155 kidney transplant recipients with known donor HLA phenotype. DNA was extracted and typing of HLA-A, B and DRB1 loci by polymerase chain reaction-specific sequence primers was performed using tailor-made condition according to the concentration of extracted DNA. HLA typing of DNA extracted from urine revealed both recipient and donor HLA phenotypes, allowing the deduction of the unknown donor HLA and hence the degree of HLA mis-match. By adopting the modified procedures, mis-matched donor HLA phenotypes were successfully deduced in all of 35 tested urine samples at DNA quantities spanning the range of 620-24,000 ng. This urine-based method offers a promising and reliable non-invasive means for the identification of mis-matched donor HLA antigens in kidney transplant recipients with unknown donor HLA phenotype or otherwise inadequate donor information.
Pellegrini, Kathryn L.; Patil, Dattatraya; Douglas, Kristen J.S.; Lee, Grace; Wehrmeyer, Kathryn; Torlak, Mersiha; Clark, Jeremy; Cooper, Colin S.; Moreno, Carlos S.; Sanda, Martin G.
2018-01-01
Background The measurement of gene expression in post-digital rectal examination (DRE) urine specimens provides a non-invasive method to determine a patient’s risk of prostate cancer. Many currently available assays use whole urine or cell pellets for the analysis of prostate cancer-associated genes, although the use of extracellular vesicles (EVs) has also recently been of interest. We investigated the expression of prostate-, kidney-, and bladder-specific transcripts and known prostate cancer biomarkers in urine EVs. Methods Cell pellets and EVs were recovered from post-DRE urine specimens, with the total RNA yield and quality determined by Bioanalyzer. The levels of prostate, kidney, and bladder-associated transcripts in EVs were assessed by TaqMan qPCR and targeted sequencing. Results RNA was more consistently recovered from the urine EV specimens, with over 80% of the patients demonstrating higher RNA yields in the EV fraction as compared to urine cell pellets. The median EV RNA yield of 36.4 ng was significantly higher than the median urine cell pellet RNA yield of 4.8 ng. Analysis of the post-DRE urine EVs indicated that prostate-specific transcripts were more abundant than kidney- or bladder-specific transcripts. Additionally, patients with prostate cancer had significantly higher levels of the prostate cancer-associated genes PCA3 and ERG. Conclusions Post-DRE urine EVs are a viable source of prostate-derived RNAs for biomarker discovery and prostate cancer status can be distinguished from analysis of these specimens. Continued analysis of urine EVs offers the potential discovery of novel biomarkers for pre-biopsy prostate cancer detection. PMID:28419548
Pellegrini, Kathryn L; Patil, Dattatraya; Douglas, Kristen J S; Lee, Grace; Wehrmeyer, Kathryn; Torlak, Mersiha; Clark, Jeremy; Cooper, Colin S; Moreno, Carlos S; Sanda, Martin G
2017-06-01
The measurement of gene expression in post-digital rectal examination (DRE) urine specimens provides a non-invasive method to determine a patient's risk of prostate cancer. Many currently available assays use whole urine or cell pellets for the analysis of prostate cancer-associated genes, although the use of extracellular vesicles (EVs) has also recently been of interest. We investigated the expression of prostate-, kidney-, and bladder-specific transcripts and known prostate cancer biomarkers in urine EVs. Cell pellets and EVs were recovered from post-DRE urine specimens, with the total RNA yield and quality determined by Bioanalyzer. The levels of prostate, kidney, and bladder-associated transcripts in EVs were assessed by TaqMan qPCR and targeted sequencing. RNA was more consistently recovered from the urine EV specimens, with over 80% of the patients demonstrating higher RNA yields in the EV fraction as compared to urine cell pellets. The median EV RNA yield of 36.4 ng was significantly higher than the median urine cell pellet RNA yield of 4.8 ng. Analysis of the post-DRE urine EVs indicated that prostate-specific transcripts were more abundant than kidney- or bladder-specific transcripts. Additionally, patients with prostate cancer had significantly higher levels of the prostate cancer-associated genes PCA3 and ERG. Post-DRE urine EVs are a viable source of prostate-derived RNAs for biomarker discovery and prostate cancer status can be distinguished from analysis of these specimens. Continued analysis of urine EVs offers the potential discovery of novel biomarkers for pre-biopsy prostate cancer detection. © 2017 Wiley Periodicals, Inc.
Yang, Chun-Chun; Yang, Stephen Shei-Dei; Hung, Hui-Ching; Chiang, I-Ni; Peng, Chiung-Hui; Chang, Shang-Jen
2017-09-01
To evaluate the ability of laser flow cytometry to predict cocci/mixed growth in the pre-analytical phase of urine specimens. We retrospectively reviewed urine samples from women with uncomplicated urinary tract infections from urologic clinics for study. Urine analyses were performed with laser flow cytometry (UF1000i, Sysmex, Kobe, Japan) and then diagrams were generated (forward scatter vs. fluorescent light scatter). Each specimen (bacteria count >357 BACT/μL) was classified as either cocci bacteria or rods/mixed growth according to the diagrams. Standard urine cultures were performed, and the agreement between cultures and the UF1000i interpretations was analyzed with kappa statistics. Finally, 491 specimens met the criteria for analysis. Among the 376 specimens with single bacteria growth, there were 26 gram-positive cocci (13 Streptococci spp., 7 Staphylococci spp., 6 Enterococci spp.), 1 gram-positive rods (Corynebacterium spp.), and 349 gram-negative rods (273 Escherichia coli, 33 Klebsiella spp., 29 Proteus spp., 6 Citrobacter spp., 4 Enterobacter spp., 3 Pseudomonas spp., and 1 Providencia spp.). There were 115 specimens with two bacteria species or more that were regarded as mixed growth. Agreement of rods or cocci/mixed growth between the laser flow cytometry and urine cultures yielded a kappa value of 0.58. The positive and negative predictive rate of the UF1000i for cocci/mixed growth in voided urine culture was 81.8% and 84.7%, respectively. Through laser flow cytometry, we can predict growth of cocci/mixed growth in the pre-analytical phase of urine culture, thus avoiding unnecessary urine culture and waiting time. © 2016 Wiley Periodicals, Inc.
Mizutani, Tatsushi; Yoshimoto, Takashi; Ishii, Akira
2018-05-21
We examined postmortem β-hydroxybutyrate (BHB) levels in the body fluids obtained from 253 forensic autopsy cases whose causes of death were determined. Postmortem changes of BHB levels according to postmortem intervals (PMI) in various body fluids (plasma, urine, vitreous humor, and pericardial fluids) were investigated to determine appropriate alternative specimens as plasma samples. Our study has indicated the following points: 1) the BHB levels in plasma specimens from three sampling sites showed no significant differences, 2) postmortem changes of BHB levels in plasma and pericardial fluids could be negligible within 96 h PMI, while urine and vitreous humor BHB levels showed postmortem changes, and 3) pericardial fluid would thus be most suitable as an alternative to plasma in postmortem BHB level. We have also proposed that BHB levels could be applicable for the diagnosis of metabolic disorders in forensic autopsy. Copyright © 2018 Elsevier B.V. All rights reserved.
Monsen, T; Ryden, P
2017-09-01
Urinary tract infections (UTIs) are among the most common bacterial infections in men and urine culture is gold standard for diagnosis. Considering the high prevalence of culture-negative specimens, any method that identifies such specimens is of interest. The aim was to evaluate a new screening concept for flow cytometry analysis (FCA). The outcomes were evaluated against urine culture, uropathogen species and three conventional screening methods. A prospective, consecutive study examined 1,312 urine specimens, collected during January and February 2012. The specimens were analyzed using the Sysmex UF1000i FCA. Based on the FCA data culture negative specimens were identified in a new model by use of linear discriminant analysis (FCA-LDA). In total 1,312 patients were included. In- and outpatients represented 19.6% and 79.4%, respectively; 68.3% of the specimens originated from women. Of the 610 culture-positive specimens, Escherichia coli represented 64%, enterococci 8% and Klebsiella spp. 7%. Screening with FCA-LDA at 95% sensitivity identified 42% (552/1312) as culture negative specimens when UTI was defined according to European guidelines. The proposed screening method was either superior or similar in comparison to the three conventional screening methods. In conclusion, the proposed/suggested and new FCA-LDA screening method was superior or similar to three conventional screening methods. We recommend the proposed screening method to be used in clinic to exclude culture negative specimens, to reduce workload, costs and the turnaround time. In addition, the FCA data may add information that enhance handling and support diagnosis of patients with suspected UTI pending urine culture [corrected].
Elliott, Simon P
2003-04-23
The endogenous nature of the drug of abuse gamma hydroxybutyric acid (GHB) has caused various interpretative problems for toxicologists. In order to obtain data for the presence of endogenous GHB in humans and to investigate any factors that may affect this, a volunteer study was undertaken. The GHB concentrations in 119 urine specimens from GHB-free subjects and 25 urine specimens submitted for toxicological analysis showed maximal urinary GHB concentrations of 3mg/l. Analysis of 15 plasma specimens submitted for toxicological analysis detected no measurable GHB (less than 2.5mg/l). Studies in a male and female volunteer in which different dietary food groups were ingested at weekly intervals, showed significant creatinine-independent intra-individual fluctuation with overall urine GHB concentrations between 0 and 2.55, and 0 and 2.74mg/l, respectively. Urinary concentrations did not appear to be affected by the particular dietary groups studied. The concentrations measured by gas chromatography with flame ionisation detection (GC-FID) and gas chromatography with mass spectrometry (GC-MS) lend further support to the proposed urinary and plasma interpretative cut-offs of 10 and 4mg/l, respectively, where below this it is not possible to determine whether any GHB detected is endogenous or exogenous in nature.
Matos, Olga; Lobo, Maria L; Gonçalves, Luzia; Antunes, Francisco
2002-01-01
The calcofluor stain (CF), the monoclonal antibody (MAb) 3B6 indirect immunofluorescence assay (IFA) and the modified trichrome blue stain (MT) were compared in terms of their reproducibility in a routine laboratory and in order to evaluate the percentage of cases of microsporidiosis in Portuguese HIV patients. A total of 166 faeces samples, 71 pulmonary specimens and 43 urine samples were studied using the 3 techniques. CF had a high sensitivity and a moderate specificity when applied to faeces samples. The sensitivity was lower with pulmonary specimens. The method is easy and quick to perform but readings take a long time to obtain. The MAb 3B6 IFA had a good to excellent sensitivity when applied to faeces and urine samples, but moderate sensitivity in pulmonary specimens. Readings were quick and easy to obtain, but the assay took longer to perform than the other 2 techniques. There was a greater correlation between the results obtained with the MT and MAb 3B6 IFA techniques than between those obtained with the MT and CF techniques. In conclusion, the MT performed better than the MAb 3B6 IFA and CF and continues to have an important place in a routine laboratory for the diagnosis of microsporidiosis. This work also confirms the existence of a relatively high proportion (30%) of cases of infection with Microsporidia, especially intestinal microsporidiosis, in HIV patients in Portugal.
Kennedy, Mary Jayne; Griffin, Angela; Su, Ruifeng; Merchant, Michael; Klein, Jon
2011-01-01
Urinary proteomic profiling has potential to identify candidate biomarkers of renal injury in infants provided an adequate urine sample can be obtained. Although diapers are used to obtain urine for clinical evaluation, their use for proteomic analysis has not been investigated. We therefore performed feasibility studies on the use of diaper-extracted urine for 2-dimensional polyacrylamide gel electrophoresis (2D-PAGE). Pediatric waste urine (2–20 mL) was applied to gel-containing, non-gel and cotton-gauze diapers and then mechanically expressed. Urine volume and total protein were measured pre- and post-extraction. Proteins were separated via 2D-PAGE following application of urine (20–40 mL) to each matrix. 2D-PAGE was also performed on clinical specimens collected using each diaper type. Differences in the adsorption and retention of urine volume and protein were noted between matrices. Non-gel and cotton-gauze diapers provided the best protein/volume recovery and the lowest interference with the Bradford assay. 2D-PAGE was also successfully completed using urine samples from both cotton fiber matrices. Conversely, samples from low-gel diapers demonstrated poor protein separation and reproducibility. Diapers containing cotton-fiber matrices appear adequate for 2D-PAGE. Qualitative and quantitative analyses of resolved proteins using replicate, high resolution gels will be required, however, before diaper-extracted urine can be applied in proteomic profiling. PMID:21137001
IL-6 does not predict current urolithiasis in stone formers.
Rieder, Jocelyn M; Nisbet, Alan A; Lesser, Timothy; Franke, Ethan I; Brusky, John P; Parekh, Ashish R; Kaptein, John; Bellman, Gary C
2008-10-01
Interleukin-6 (IL-6), an inflammatory marker, has previously been found to be elevated in the urine of patients with urolithiasis. Oxalate and other stone precursors have been shown to increase IL-6 production in proximal tubular epithelial cells in vitro. We examined whether urinary IL-6 could be used as a screening test to determine current urolithiasis in individuals who are known to form urinary stones. Thirty-five adult patients with current urolithiasis demonstrated on imaging were enrolled in the study. Exclusion criteria included disease known to elevate IL-6. Each patient provided a pre-treatment urine specimen and one month after proven to be stone-free an additional urine specimen was obtained. The urinary IL-6/creatinine ratio was determined for both specimens and compared. Ten patients provided both specimens. The mean pre-operative urinary IL-6/creatinine ratio before the procedure was 1.63 pg/mL. The mean post procedure urinary IL-6/creatinine ratio after the patient was confirmed to be stone-free was 1.81 pg/mL. These were not significantly different (p=0.38). Preoperative urinary IL-6/creatinine ratio did not correlate to stone size (r=0.15) and no correlation was seen between time from treatment and stone free IL-6/creatinine ratio (r=0.48). Urinary IL-6 is not a good screening test for current urolithiasis in stone-forming individuals. It is elevated whether the stone is present or not.
Tamayo, Javier; Gómez-Garcés, José-Luis; Alós, Juan-Ignacio
2004-08-01
The Granada agar plate (GAP; Biomedics SL, Madrid, Spain) was evaluated for the detection of group B streptococci (GBS) in urine specimens from pregnant women submitted for testing for asymptomatic bacteriuria and was compared with blood agar (BA [Columbia agar with 5% sheep blood]; bioMérieux, Marcy l'Etoile, France). The GAP detected 103 out of 105 GBS, whereas BA detected only 50. Use of the GAP could be a good method for the detection of GBS in urine specimens from pregnant women.
Tivapasi, Musavenga T; Hodges, Joanne; Byrne, Barbara A; Christopher, Mary M
2009-09-01
Urinary tract infections (UTIs) may be subclinical or difficult to detect in dilute urine as sediment abnormalities may not be observed. In our laboratory, bacterial culture is automatically performed (reflex culture) on samples with urine specific gravity (USG)< or =1.013 to increase the likelihood of detecting infection. The value of routine culture of dilute urine, however, has not been fully assessed. The purpose of this retrospective study was to evaluate the frequency of positive bacterial cultures and analyze the diagnostic utility and cost-effectiveness of culture compared with routine sediment examination for detecting UTI in dilute urine specimens from dogs. Urinalysis and concurrent aerobic bacterial culture results were obtained from the electronic medical record system at the University of California-Davis Veterinary Medical Teaching Hospital for samples with USG< or =1.013 analyzed from July 1998 through January 2005. Urine collection method, presence of leukocytes and bacteria, bacterial culture results, and clinical diagnosis were recorded. Cost-effectiveness of reflex culture, based on low USG as the sole criterion, was evaluated. Of 1264 urine specimens, 106 (8.4%) had positive bacterial cultures. Using culture as the gold standard, sediment evaluation had a diagnostic sensitivity of 58.5% and specificity of 98.3% (diagnostic accuracy 94.9%). An additional cost of $60 per patient was incurred, leading to average annual costs of $11,668 for reflex bacterial cultures of all samples with low USG, regardless of collection method. Within our study population, 10 urine samples needed to be cultured for each true positive result. The sensitivity of urine sediment evaluation is low for UTI in dilute urine samples; however, reflex bacterial culture does not appear to be cost-effective in dogs with USG< or =1.013 in the absence of active urine sediment or high clinical suspicion for UTI.
Herreros, María Luisa; Tagarro, Alfredo; García-Pose, Araceli; Sánchez, Aida; Cañete, Alfonso; Gili, Pablo
2015-01-01
OBJECTIVE: To evaluate the accuracy of diagnosing urinary tract infections using a new, recently described, standardized clean-catch collection technique. METHODS: Cross-sectional study of infants <90 days old admitted due to fever without a source, with two matched samples of urine obtained using two different methods: clean-catch standardized stimulation technique and bladder catheterization. RESULTS: Sixty paired urine cultures were obtained. The median age was 44-days-old. Seventeen percent were male infants. Clean-catch technique sensitivity was 97% (95% CI 82% to 100%) and specificity was 89% (95% CI 65% to 98%). The contamination rate of clean-catch samples was lower (5%) than the contamination rate of catheter specimens (8%). CONCLUSIONS: The sensitivity and specificity of urine cultures obtained using the clean-catch method through the new technique were accurate and the contamination rate was low. These results suggest that this technique is a valuable, alternative method for urinary tract infection diagnosis. PMID:26435675
Denning, D W; Stevens, D A; Hamilton, J R
1990-01-01
Growth of Cryptococcus neoformans from the sputum of patients with acquired immunodeficiency syndrome may be obscured by oral contamination with Candida albicans on conventional media. We prospectively compared direct plating of sputum and urine onto birdseed agar and compared birdseed agar plating with plating onto Mycosel and Sabouraud dextrose agar cultures. Thirty-two sputum and three urine specimens were compared. C. neoformans was isolated from five specimens. In two specimens, one of sputum and one of urine, C. neoformans was detected only on the birdseed agar plate because of overgrowth on the conventional media by C. albicans. C. neoformans produced dark colonies on birdseed agar, unlike C. albicans, which produces white colonies. The use of birdseed agar as the primary culture medium for sputum and urine specimens from patients with acquired immunodeficiency syndrome increases sensitivity for C. neoformans. Images PMID:2254431
Miller, Katie L; Puet, Brandi L; Roberts, Ali; Hild, Cheryl; Carter, Jason; Black, David L
2017-05-01
Urine drug testing is recommended for individuals receiving medication-assisted treatment. It provides objective information for practitioners to consider and may serve as a protective factor against drug-related mortality. The primary objective of our study was to describe urine drug testing results for patients undergoing long-term medication-assisted treatment (≥6months). The secondary objective was to provide further evidence to establish oral fluid as a reliable alternative to urine. All subjects (n=639) included in the study were enrolled in one of five treatment centers in the state of Tennessee, and all urine specimens were positive for either methadone or buprenorphine. Nicotine (87%), caffeine (70%), marijuana (15%), alcohol (14%) and gabapentin (10%) were the most prevalent substances identified through urine drug testing. The presence of non-maintenance opioids (prescription and/or heroin) may represent relapse; these drugs were present in 10% of specimens tested. Evidence of illicit drug use (cocaine, heroin, marijuana and/or methamphetamine) was detected in 19% specimens. For 126 of the 639 subjects included in the study, paired oral fluid and urine test results were compared for agreement. Of the total paired urine and oral fluid tests, approximately 7% were positive for a drug in both specimen types and 91% were negative in both, resulting in an overall agreement of 98%. The study demonstrates continued use of illicit and commercially available medications in a medication-assisted treatment population undergoing long-term treatment. The results affirm the reliability of oral fluid as an alternative specimen type for compliance testing in this population. Copyright © 2017 Elsevier Inc. All rights reserved.
Evaluation of ames Multistix-SG for urine specific gravity versus refractometer specific gravity.
Adams, L J
1983-12-01
A comparison of urine specific gravity by a commercially available multiple reagent strip (Multistix-SG; Ames Division, Miles Laboratory) versus refractometer specific gravity (TS Meter; American Optical Corporation) was performed on 214 routine urine specimens. Agreement to +/- 0.005 was found in 72% of the specimens (r = 0.80). Urine specific gravity by the Multistix-SG showed a significant positive bias at urine pHs less than or equal to 6.0 and a negative bias at urine pHs greater than 7.0 in comparison to refractometer specific gravity. At concentrated (specific gravity greater than or equal to 1.020) specific gravities, up to 25% of urine specimens were misclassified as not concentrated by Multistix-SG specific gravity in comparison to refractometer specific gravity. The additional cost of the specific gravity reagent to a multiple reagent test strip in addition to the poor performance relative to refractometer specific gravity leads to the conclusion that including this specific gravity methodology on a multiple reagent strip is neither cost effective nor clinically useful.
Luong, Susan; Ung, Alison T; Kalman, John; Fu, Shanlin
2014-07-30
Pyridinium chlorochromate (PCC) is the active ingredient of 'Urine Luck', a commercially available in vitro adulterating agent used to conceal the presence of drugs in a urine specimen. The exposure of codeine and its major glucuronide metabolite codeine-6-glucuronide (C6G) to PCC was investigated to determine whether PCC is an effective masking agent for these opiate compounds. Following the addition of PCC to both spiked and authentic codeine and C6G-positive urine specimens, the samples were monitored using liquid chromatography/mass spectrometry (LC/MS). Stable reaction products were identified and characterized using high-resolution MS analysis and, where possible, nuclear magnetic resonance (NMR) analysis. It was determined that PCC effectively oxidizes codeine and C6G, thus altering the original codeine-to-C6G ratio in the urine specimen. Four reaction products were identified for codeine: codeinone, 14-hydroxycodeinone, 6-O-methylcodeine and 8-hydroxy-7,8-dihydrocodeinone. Similarly, three reaction products were identified for C6G: codeinone, codeine and a lactone of C6G (tentative assignment). Besides addressing the complications added to interpretation, more investigation is warranted to further determine their potential for use as markers for monitoring the presence of codeine and C6G in urine specimens adulterated with PCC. Copyright © 2014 John Wiley & Sons, Ltd.
Tokuhara, Yasunori; Shukuya, Kenichi; Tanaka, Masami; Mouri, Mariko; Ohkawa, Ryunosuke; Fujishiro, Midori; Takahashi, Tomoo; Okubo, Shigeo; Yokota, Hiromitsu; Kurano, Makoto; Ikeda, Hitoshi; Yamaguchi, Seiji; Inagaki, Shinobu; Ishige-Wada, Mika; Usui, Hiromi; Yatomi, Yutaka; Shimosawa, Tatsuo
2014-01-01
Alkaptonuria, caused by a deficiency of homogentisate 1,2-dioxygenase, results in the accumulation of homogentisic acid (2,5-dihydroxyphenylacetic acid, HGA) in the urine. Alkaptonuria is suspected when the urine changes color after it is left to stand at room temperature for several hours to days; oxidation of homogentisic acid to benzoquinone acetic acid underlies this color change, which is accelerated by the addition of alkali. In an attempt to develop a facile screening test for alkaptonuria, we added alkali to urine samples obtained from patients with alkaptonuria and measured the absorbance spectra in the visible light region. We evaluated the characteristics of the absorption spectra of urine samples obtained from patients with alkaptonuria (n = 2) and compared them with those of urine specimens obtained from healthy volunteers (n = 5) and patients with phenylketonuria (n = 3), and also of synthetic homogentisic acid solution after alkalization. Alkalization of the urine samples and HGA solution was carried out by the addition of NaOH, KOH or NH4OH. The sample solutions were incubated at room temperature for 1 min, followed by measurement of the absorption spectra. Addition of alkali to alkaptonuric urine yielded characteristic absorption peaks at 406 nm and 430 nm; an identical result was obtained from HGA solution after alkalization. The absorbance values at both 406 nm and 430 nm increased in a time-dependent manner. In addition, the absorbance values at these peaks were greater in strongly alkaline samples (NaOH- KOH-added) as compared with those in weakly alkaline samples (NH4OH-added). In addition, the peaks disappeared following the addition of ascorbic acid to the samples. We found two characteristic peaks at 406 nm and 430 nm in both alkaptonuric urine and HGA solution after alkalization. This new quick and easy method may pave the way for the development of an easy method for the diagnosis of alkaptonuria.
Tokuhara, Yasunori; Shukuya, Kenichi; Tanaka, Masami; Mouri, Mariko; Ohkawa, Ryunosuke; Fujishiro, Midori; Takahashi, Tomoo; Okubo, Shigeo; Yokota, Hiromitsu; Kurano, Makoto; Ikeda, Hitoshi; Yamaguchi, Seiji; Inagaki, Shinobu; Ishige-Wada, Mika; Usui, Hiromi; Yatomi, Yutaka; Shimosawa, Tatsuo
2014-01-01
Background Alkaptonuria, caused by a deficiency of homogentisate 1,2-dioxygenase, results in the accumulation of homogentisic acid (2,5-dihydroxyphenylacetic acid, HGA) in the urine. Alkaptonuria is suspected when the urine changes color after it is left to stand at room temperature for several hours to days; oxidation of homogentisic acid to benzoquinone acetic acid underlies this color change, which is accelerated by the addition of alkali. In an attempt to develop a facile screening test for alkaptonuria, we added alkali to urine samples obtained from patients with alkaptonuria and measured the absorbance spectra in the visible light region. Methods We evaluated the characteristics of the absorption spectra of urine samples obtained from patients with alkaptonuria (n = 2) and compared them with those of urine specimens obtained from healthy volunteers (n = 5) and patients with phenylketonuria (n = 3), and also of synthetic homogentisic acid solution after alkalization. Alkalization of the urine samples and HGA solution was carried out by the addition of NaOH, KOH or NH4OH. The sample solutions were incubated at room temperature for 1 min, followed by measurement of the absorption spectra. Results Addition of alkali to alkaptonuric urine yielded characteristic absorption peaks at 406 nm and 430 nm; an identical result was obtained from HGA solution after alkalization. The absorbance values at both 406 nm and 430 nm increased in a time-dependent manner. In addition, the absorbance values at these peaks were greater in strongly alkaline samples (NaOH- KOH-added) as compared with those in weakly alkaline samples (NH4OH-added). In addition, the peaks disappeared following the addition of ascorbic acid to the samples. Conclusions We found two characteristic peaks at 406 nm and 430 nm in both alkaptonuric urine and HGA solution after alkalization. This new quick and easy method may pave the way for the development of an easy method for the diagnosis of alkaptonuria. PMID:24466168
Hashikita, Giichi; Yamaguti, Toshiyuki; Tachi, Yoshimi; Kishi, Etsuko; Kawamura, Toru; Takahashi, Shun; Arai, Yukie; Koyama, Sachie; Huruhata, Toshihumi; Itabashi, Akira; Oka, Yoko; Yamazaki, Tsutomu; Maesaki, Sigefumi
2005-01-01
We investigated the usefullness of Binax NOW urine antigen test, an immunochromatographic assay that binds any soluble Streptococcus pneumoniae antigen (C polysaccharide) for the diagnosis of penumoniae form September 2003 to March 2005. We used 372 samples form the patinets with pneumoniae diagnosed for blood or sputum cultuter or gram-stained sputum smear. Out of 24 culture positive specimens, Binax NOW urine antigen test, showed positive in 18 (75%) specimens. The sensitivity of sputum and blood culture was 71.7% and 83.3%, respectively. Binax NOW urine antigen test was seemed false positives in 55 samples, false negatives in 6 samples. The specificity of Binax NOW urine antigen test was evaluated 84.1%. Overall agreement among tests was 83.6%. When compared to culture, false negative urine antigen may be the result of colonizing S. pneumoniae in sputum or pneumonia caused by an agent other than S. pneumoniae. CRP values for cases were both urine antigen and culture were positive ranged from 40 mg/dl to 10 mg/dl while urine antigen and culture negative cases were predominantly less than 10 mg/dl. Positive blood and pleural fluid culture cases were consistently associated with strongly positive urine antigen tests. Non-agreement between urine antigen, culture, and microscopy may be the result of specimen quality, labile nature of S. pneumoniae and antimicrobial therapy.
Huysal, Kağan; Budak, Yasemin U; Karaca, Ayse Ulusoy; Aydos, Murat; Kahvecioğlu, Serdar; Bulut, Mehtap; Polat, Murat
2013-01-01
Urinary tract infection (UTI) is one of the most common types of infection. Currently, diagnosis is primarily based on microbiologic culture, which is time- and labor-consuming. The aim of this study was to assess the diagnostic accuracy of urinalysis results from UriSed (77 Electronica, Budapest, Hungary), an automated microscopic image-based sediment analyzer, in predicting positive urine cultures. We examined a total of 384 urine specimens from hospitalized patients and outpatients attending our hospital on the same day for urinalysis, dipstick tests and semi-quantitative urine culture. The urinalysis results were compared with those of conventional semiquantitative urine culture. Of 384 urinary specimens, 68 were positive for bacteriuria by culture, and were thus considered true positives. Comparison of these results with those obtained from the UriSed analyzer indicated that the analyzer had a specificity of 91.1%, a sensitivity of 47.0%, a positive predictive value (PPV) of 53.3% (95% confidence interval (CI) = 40.8-65.3), and a negative predictive value (NPV) of 88.8% (95% CI = 85.0-91.8%). The accuracy was 83.3% when the urine leukocyte parameter was used, 76.8% when bacteriuria analysis of urinary sediment was used, and 85.1% when the bacteriuria and leukocyturia parameters were combined. The presence of nitrite was the best indicator of culture positivity (99.3% specificity) but had a negative likelihood ratio of 0.7, indicating that it was not a reliable clinical test. Although the specificity of the UriSed analyzer was within acceptable limits, the sensitivity value was low. Thus, UriSed urinalysis resuIts do not accurately predict the outcome of culture.
Urine Test: Microalbumin-to-Creatinine Ratio (For Parents)
... involves measuring the amount of a protein called albumin in the urine (pee). The amount of urine albumin is compared with the quantity of a waste ... steady rate, so comparing the ratio of urine albumin with creatinine in the same urine specimen helps ...
Evaluation of urine for Leishmania infantum DNA detection by real-time quantitative PCR.
Pessoa-E-Silva, Rômulo; Mendonça Trajano-Silva, Lays Adrianne; Lopes da Silva, Maria Almerice; da Cunha Gonçalves-de-Albuquerque, Suênia; de Goes, Tayná Correia; Silva de Morais, Rayana Carla; Lopes de Melo, Fábio; de Paiva-Cavalcanti, Milena
2016-12-01
The availability of some sorts of biological samples which require noninvasive collection methods has led to an even greater interest in applying molecular biology on visceral leishmaniasis (VL) diagnosis, since these samples increase the safety and comfort of both patients and health professionals. In this context, this work aimed to evaluate the suitability of the urine as a specimen for Leishmania infantum kinetoplast DNA detection by real-time quantitative PCR (qPCR). Subsequent to the reproducibility analysis, the detection limit of the qPCR assay was set at 5fg (~0.025 parasites) per μL of urine. From the comparative analysis performed with a set of diagnostic criteria (serological and molecular reference tests), concordance value of 96.08% was obtained (VL-suspected and HIV/AIDS patients, n=51) (P>0.05). Kappa coefficient (95% CI) indicated a good agreement between the test and the set of diagnostic criteria (k=0.778±0.151). The detection of Leishmania DNA in urine by qPCR was possible in untreated individuals, and in those with or without suggestive renal impairment. Fast depletion of the parasite's DNA in urine after treatment (from one dose of meglumine antimoniate) was suggested by negative qPCR results, thus indicating it as a potential alternative specimen to follow up the efficacy of therapeutic approaches. Even when evaluated in a clinically heterogeneous set of patients, the urine showed good prospect as sample for VL diagnosis by qPCR, also indicating a good negative predictive value for untreated suspected patients. Copyright © 2016 Elsevier B.V. All rights reserved.
Ong, J J; Fethers, K; Howden, B P; Fairley, C K; Chow, E P F; Williamson, D A; Petalotis, I; Aung, E; Kanhutu, K; De Petra, V; Chen, M Y
2017-08-01
Guidelines regarding whether men who have sex with men (MSM) without symptoms of urethritis should be screened for urethral gonorrhoea differ between countries. We examined the rate of asymptomatic urethral gonorrhoea in MSM using sensitive nucleic acid amplification testing. This study was conducted on consecutive MSM attending the Melbourne Sexual Health Centre between July 2015 and May 2016 for sexually transmitted infections screening. Gonorrhoea testing with the Aptima Combo 2 (AC2) assay was performed on all urine specimens obtained from MSM, whether symptoms of urethritis were present or not. Men were classified as having: typical discharge if they reported symptoms suggesting purulent discharge; other symptoms if they reported other symptoms of urethritis; and no symptoms if they reported no urethral symptoms. During the study period, there were 7941 clinic visits by 5947 individual MSM with 7090 urine specimens obtained from 5497 individual MSM tested with the AC2 assay. Urethral gonorrhoea was detected in 242 urine specimens from 228 individual MSM. The majority (189/242, 78%, 95% CI 73-83) reported typical discharge, 27/242 (11%, 95% CI 8-16) reported other urethral symptoms, and 26/242 (11%, 95% CI 7-15) reported no symptoms on the day of presentation and testing. Among men with urethral gonorrhoea, the proportions with concurrent pharyngeal or rectal gonorrhoea were 32% (134/210) and 64% (74/235), respectively. The mean interval between last reported sexual contact and onset of typical urethral discharge, where present, was 3.9 days. The findings from our study lend support to guidelines that recommend screening asymptomatic MSM for urethral gonorrhoea. Copyright © 2017 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
Krepel, J; Patel, J; Sproston, A; Hopkins, F; Jang, D; Mahony, J; Chernesky, M
1999-10-01
Nucleic acid amplification testing is the most accurate approach to diagnosing Chlamydia trachomatis infections. Our objective was to compare the accuracy and cost savings of pooling urines as opposed to individual testing. Strategies of pooling urine specimens into groups of four (4x pool) or eight (8x pool) followed by testing the positive pools individually were compared to individual specimen testing to determine if significant cost savingS could be realized without compromising the sensitivity and specificity of the LCx C. trachomatis Assay (Abbott Laboratories, Abbott Park, Chicago, IL) performed in a busy private medical laboratory. A total of 1,220 patient urine samples, 1,187 male (97%) and 33 female (3%), were tested using the normal LCx specimen to cutoff ratio (S/CO) of 1.0 and a decreased S/CO value of 0.2. Individual testing identified 98.2% (109/111) of positive urines. The 4x pooling maneuver identified 92.8% (103/111) of positive patients with the regular cutoff and 96.4% (107/111) when the cutoff was decreased. These values were 95.9% (47/49) and 97.9% (48/49), respectively, when eight urines were pooled. Both pooling and individual testing strategies identified all the negative samples accurately. Cost savings of pooling were calculated to be 44.5% for pools of four and 37.5% for pools of eight, applying the lowered cutoff. Pooling urine specimens for testing with the C. trachomatis LCx system is a simple, accurate, and cost-saving approach that can significantly reduce the cost of amplified nucleic acid testing with minimal sacrifice of testing accuracy.
49 CFR 40.13 - How do DOT drug and alcohol tests relate to non-DOT tests?
Code of Federal Regulations, 2010 CFR
2010-10-01
... drugs, and a laboratory is prohibited from making a DOT urine specimen available for a DNA test or other... a blood or urine specimen collected by the employee's physician or a DNA test result purporting to...
49 CFR 40.13 - How do DOT drug and alcohol tests relate to non-DOT tests?
Code of Federal Regulations, 2011 CFR
2011-10-01
... drugs, and a laboratory is prohibited from making a DOT urine specimen available for a DNA test or other... a blood or urine specimen collected by the employee's physician or a DNA test result purporting to...
49 CFR 40.13 - How do DOT drug and alcohol tests relate to non-DOT tests?
Code of Federal Regulations, 2012 CFR
2012-10-01
... drugs, and a laboratory is prohibited from making a DOT urine specimen available for a DNA test or other... a blood or urine specimen collected by the employee's physician or a DNA test result purporting to...
49 CFR 40.13 - How do DOT drug and alcohol tests relate to non-DOT tests?
Code of Federal Regulations, 2014 CFR
2014-10-01
... drugs, and a laboratory is prohibited from making a DOT urine specimen available for a DNA test or other... a blood or urine specimen collected by the employee's physician or a DNA test result purporting to...
49 CFR 40.13 - How do DOT drug and alcohol tests relate to non-DOT tests?
Code of Federal Regulations, 2013 CFR
2013-10-01
... drugs, and a laboratory is prohibited from making a DOT urine specimen available for a DNA test or other... a blood or urine specimen collected by the employee's physician or a DNA test result purporting to...
Samala, Devdas S.; Parelkar, Sandesh V.; Sanghvi, Beejal V.; Vageriya, Natasha L.; Paradkar, Bhupesh A.; Kandalkar, Bhuvaneshwari M.; Sathe, Pragati A.
2014-01-01
Objectives: The aim of this experimental study was to observe the intensity of the inflammatory reaction caused by neonatal urine and meconium on the intestinal wall of rats to better understand etiology of intestinal damage in gastroschisis. Materials and Methods: A total of 24 adult Wistar rats were used as experimental models to simulate the effect of exposed bowel in cases of gastroschisis. The peritoneal cavity of the rats was injected with substances which constitute human amniotic fluid to study the effect on the bowel. Sterile urine and meconium were obtained from newborn humans. The rats were divided into four groups according to the material to be injected. In Group I (Control group) 3 mL of distilled water was injected, in Group II (Urine group) 3 mL of neonatal urine was injected, in Group III (Meconium group) 5% meconium suspension was injected, while in Group IV, a combination of 5% meconium suspension and urine was injected. A total of 3mL solution was injected into the right inferior quadrant twice a day for 5 days. The animals were sacrificed on the 6th day by a high dose of thiopentone sodium. A segment of small bowel specimen was excised, fixed in paraffin, and stained with hematoxylin-eosin for microscopic analysis for determination of the degree of inflammatory reaction in the intestinal wall. All pathology specimens were studied by the same pathologist. Results: The maximum bowel damage was seen in Group II (Urine group) in the form of serositis, severe enteritis, parietal necrosis, and peeling. A lesser degree of damage was observed in Group III (Meconium group) as mild enteritis (mild lymphoid hyperplasia). The least damage was seen in Group IV (Combination of meconium and urine) and Group I (Control group). Conclusion: The intraabdominal injection of neonatal human urine produces significant inflammatory reactions in the intestinal wall of rats. PMID:24604977
Rothschild, Bruce
2016-05-01
The ability of health care professionals to provide patient care is potentially compromised when predicated on untested, although longstanding, perspectives. One such example is urinalysis testing, which has been currently simplified to use only urine testing strips for detection of microscopic hematuria. To determine whether urine testing strips are sufficient for identification of clinically significant findings in urinalysis. To determine the presence of microscopic hematuria, I examined a collection of urine specimens that had tested heme negative during the 3-month study period. Of the 342 patients from whom urine specimens were examined during this interval, 50 had microscopic hematuria, despite having tested negative for heme via urine testing strip. Also, 30% were not receiving any medication known to produce microscopic hematuria, and 18% had clinically significant pathology. Diagnosis of significant clinical pathologic manifestations would have been compromised had microscopic examination not been performed on the urine specimens from the cohort individuals. Examination of the novel approach of including microscopic examination of specimens in a specific clinical situation challenges the dominant paradigm of reliance on assaying using urine testing strips only, revealing that the current method is not only unreliable for determining microscopic hematuria but also is less than optimal in general clinical practice. The findings of this study provide evidence of the importance of microscopic evaluation as a routine component of urinalysis. © American Society for Clinical Pathology, 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Crystallization processes derived from the interaction of urine and dolostone
NASA Astrophysics Data System (ADS)
Cámara, Beatriz; Alvarez de Buergo, Monica; Fort, Rafael
2015-04-01
The increase in the number of pets (mostly dogs), homeless people and the more recent open-air drinking sessions organized by young people in historical centers of European cities, derive on the augmentation of urinations on stone façades of the built cultural heritage. Up to now this process has been considered only under an undesirable aesthetical point of view and the insalubrious conditions it creates, together with the cleaning costs that the local governments have to assume. This study aims to confirm urine as a real source of soluble salts that can trigger the decay of building materials, especially of those of built cultural heritage of the historical centers of the cities, which are suffering the new social scenario described above. For this purpose, an experimental setup was designed and performed in the laboratory to simulate this process. 5 cm side cubic specimens of dolostone were subjected to 100 testing cycles of urine absorption by capillarity. The necessary amount of urine was collected by donors and stored following clinical protocol conditions. Each cycle consisted of imbibitions of the specimens in 3 mm high urine sheet for 3 hours, drying at 40°C in an oven for 20 hours and 1 hour cooling in a dessicator. At the end of the 100 cycles, small pieces of the specimens were cut, observed and analyzed with the aid of an environmental scanning electron microscope, which presents the advantage of no sample preparation. The sampled pieces were selected considering there were different sections in height in the specimens: a) a bottom section that corresponds to the section that has been immersed in the urine solution (3 mm); b) an interface section, immediately above the immersed area, which is the area most affected by the urine capillarity process, characterized by a strong yellowish color; c) the section that we have named as section of influence, which is subjected to the capillary absorption, although not so strongly than the interface section (these 3 sections, a) b) c) represent the first one centimeter of the specimen from the bottom); d) and the fourth and top section, which shows no influence by the effect of urine capillary absorption. The obtained results showed, from bottom to top, the following crystallized salts: a) abundant prismatic crystals enriched in P and Ca (calcium phosphate); b) amorphous round-shaped potassium sulfate crystals and cubic sodium chloride crystals embedded in an organic matrix; d) cubic sodium chloride crystals are dominant. In the unaffected area, no other crystals were detected different from the carbonate minerals forming the rock. These results are in accordance to which has already been published by the authors in granitic materials (Cámara et al 2014). Acknowledgements: to Geomateriales 2 programme (S2013/MIT-2914) funded by the Community of Madrid. Cámara B., Alvarez de Buergo, M.; Fort, R.; Ascaso, C. de los Rios, A.; Gomez-Heras, M. 2014. Another source of soluble salts in urban environments due to recent social behaviour pattern in historical centres. In: Science, Technology and Cultural Heritage (edited by M.A. Rogerio-Candelera), 89-94. CRC Press-Balkema, Taylor and Francis. ISBN 9781138027442 - CAT# K25502
The consequence of delayed fixation on subsequent preservation of urine cells.
Ahmed, Hussain G; Tom, Murtada Am
2011-01-01
Degenerative changes caused by delays in urine preservation contribute to false-negative and false-positive interpretation of urothelial disease in cytology. The aim of this study is to assess whether the delay of fixation of urine samples makes any significant difference to urine cytology and morphology, and the limit of acceptability of delay for routine use in the hospital laboratory. Three cell collection fluids were evaluated by analyzing the preservation and degeneration of cells in urine samples. In this study, 50 voided urine specimens were taken at random from females complaining of vaginal discharge. Each specimen was divided into three sterile containers. The first was immediately centrifugated and the deposit was smeared onto a cleaned micro slide and immediately fixed into 95% ethyl alcohol for 15 minutes. The remaining two were prepared in the same manner, however, the second after two hours of collection and the third after four hours of collection. The degree of degeneration and thus the preservation were assessed by a table of chosen criteria, then ranked and analyzed using Friedman's nonparametric test, at p=0.05. The results showed a significant difference between the preservation and the delay in urine fixation, p<0.0001. Any delay in fixation of urine specimen for cytology affects the preservation of cells, which may result in miss diagnosis. It is recommended that urine samples for cytology should be fixed immediately after collection.
Laboratory aspects of asymptomatic bacteriuria in pregnancy.
Mohammad, Marlyn; Mahdy, Zaleha A; Omar, Jamil; Maan, Noorashikin; Jamil, M A
2002-09-01
A total of 1,661 pregnant women aged between 13 and 45 years were screened for bacteriuria by urine culture. Of the 1,661 culture results, 615 (37%) yielded no growth; 728 (43.8%) yielded no significant growth (presence of <10(5) organisms/ml urine of one or more types of bacteria); 286 (17.2%) yielded mixed growth (presence of >10(5) organisms/ml urine of more than one type of bacteria) and only 32 (1.9%) showed significant growth (presence of >10(5) organisms/ml urine of a single bacterium). Urine microscopy was also conducted. Two hundred and twenty-four (13.5%) specimens had >10 white blood cells/ml urine, of which 66 had >100 white blood cells; 13 were from the significant growth group. Three hundred and seventy-four (22.5%) specimens showed the presence of bacteria, 42 (2.5%) had red blood cells, 370 (22.3%) had epithelial cells, 58 (3.5%) had crystals, and 14 (0.8%) had yeasts. The most common bacterium isolated was Escherichia coli (12; 40%); the others included group B Streptococcus (5; 15%), Klebsiella spp (5; 15%), Diphtheroids (2), and Candida albicans (2). Fifty-two percent of tested strains were sensitive to ampicillin; 24 of 28 strains (85.7%) were sensitive to ciprofloxacin; all 7 strains tested were sensitive to nitrofurantoin and all 20 strains tested were sensitive to cotrimoxazole; 14/20 (70%) and 16/17 (94.1%) were sensitive to cephalexin and cefuroxime respectively. This study shows that asymptomatic bacteriuria does occur in pregnant women, albeit at a very low rate in an urban setting like Cheras. Urine microscopy is not specific and only serves as a guide to bacteriuria. The commonest causative organisms are those from the gastrointestinal tract and vagina. The antibiogram showed that cefuroxime and cephalexin are likely to be effective in treating bacteriuria: ampicillin must be reserved for Gram-negative organisms. For Gram-positive organisms, of which Group B Streptococcus is important, ampicillin is still effective in vitro. Nitrofurantion and cotrimoxazole have excellent activity in vitro and should be considered for therapy. 17.2% of the urine culture yielded mixed growth: likely to indicate that contamination of urine specimens still happens despite the strict instructions given to patients about the collection of a midstream urine specimen. Proper collection, appropriate transport, and the early processing of urine specimens remain essential.
Cómbita, Alba Lucía; Gheit, Tarik; González, Paula; Puerto, Devi; Murillo, Raúl Hernando; Montoya, Luisa; Vorsters, Alex; Van Keer, Severien; Van Damme, Pierre; Tommasino, Massimo; Hernández-Suárez, Gustavo; Sánchez, Laura; Herrero, Rolando; Wiesner, Carolina
2016-09-01
Urine sampling for HPV DNA detection has been proposed as an effective method for monitoring the impact of HPV vaccination programs; however, conflicting results have been reported. The goal of this study was to evaluate the performance of optimized urine HPV DNA testing in women aged 19 to 25 years. Optimization process included the use of first void urine, immediate mixing of urine with DNA preservative, and the concentration of all HPV DNA, including cell-free DNA fragments. Urine and cervical samples were collected from 535 young women attending cervical screening at health centers from two Colombian cities. HPV DNA detection and genotyping was performed using an HPV type-specific multiplex genotyping assay, which combines multiplex polymerase chain reaction with bead-based Luminex technology. Concordance between HPV DNA detection in urine and cervical samples was determined using kappa statistics and McNemar tests. The accuracy of HPV DNA testing in urine samples was evaluated measuring sensitivity and specificity using as reference the results obtained from cervical samples. Statistical analysis was performed using STATA11.2 software. The findings revealed an overall HPV prevalence of 60.00% in cervical samples and 64.72% in urine samples, HPV-16 being the most frequent HPV type detected in both specimens. Moreover, our results indicate that detection of HPV DNA in first void urine provides similar results to those obtained with cervical samples and can be used to monitor HPV vaccination trials and programs as evidenced by the substantial concordance found for the detection of the four vaccine types. Cancer Prev Res; 9(9); 766-71. ©2016 AACR. ©2016 American Association for Cancer Research.
The use of isoniazid as a marker to monitor the self-administration of medicaments.
Stark, J E; Ellard, G A; Gammon, P T; Fox, W
1975-01-01
1. Isoniazid was used as a marker to monitor the regularity of drug self-administration in a trial of chemoprophylaxis against natural influenza infection. Two hundred and sixty-two volunteers were treated for five weeks with a synthetic isoquinoline compound (U.K. 2371) or a matching placebo. 2. Five marker tablets containing isoniazid (150 mg) were incorporated into each regimen and their ingestion monitored by testing for acetylisoniazid in the urine. 3. Positive evidence of marker tablet consumption was obtained on 75% of the occasions on which urine samples were requested. The results obtained among the volunteers from each treatment group who returned urine specimens as requested (92%) indicated that they had swallowed at least 81% of their prescribed tablets. 4. The findings of the study suggest that when used in this way isoniazid is a very suitable compound for use on a few occasions for monitoring the self-administration of drugs in clinical trials. PMID:788733
Psilocin identified in a DUID investigation.
Tiscione, Nicholas B; Miller, Mattheu I
2006-06-01
Psilocin was identified in a urine specimen collected during a routine driving under the influence of drugs investigation, the first for this laboratory. The subject did not exhibit any response to an automobile crash, indicating the he may have been unaware of the severity of the situation or his immediate surroundings. The urine specimen gave a positive result on a fluorescence polarization immunoassay amphetamine/methamphetamine assay, and psilocin was determined to have 1.3% cross-reactivity at 50 mg/L. Psilocin was confirmed by gas chromatography-mass spectrometry following an extraction for acidic, neutral, and basic drugs. Hydrolysis and derivatization techniques were not employed. The urine concentration of psilocin decreased rapidly, although the specimen was maintained at 4 degrees C.
Łukasik-Głębocka, Magdalena; Sommerfeld, Karina; Hanć, Anetta; Grzegorowski, Adam; Barałkiewicz, Danuta; Gaca, Michał; Zielińska-Psuja, Barbara
2014-01-01
A serious case of barium intoxication from suicidal ingestion is reported. Oral barium chloride poisoning with hypokalemia, neuromuscular and cardiac toxicity, treated with intravenous potassium supplementation and hemodialysis, was confirmed by the determination of barium concentrations in gastric contents, blood, serum and urine using the inductively coupled plasma mass spectrometry method. Barium concentrations in the analyzed specimens were 20.45 µg/L in serum, 150 µg/L in blood, 10,500 µg/L in urine and 63,500 µg/L in gastric contents. Results were compared with barium levels obtained from a non-intoxicated person. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
High apoptotic index in urine cytology is associated with high-grade urothelial carcinoma.
Yang, Chi-Shun; Chen, Shaoxiong; Cramer, Harvey M; Wu, Howard H
2016-08-01
The significance of apoptosis and its association with high-grade urothelial carcinoma (HGUC) in urine cytology has yet to be determined. A computerized search of the study laboratory information system was performed over a 3-year period for all urine cytology specimens processed using the SurePath liquid-based preparation technique. Only those cases with correlating surgical pathology obtained within 6 months after the urine cytologic samples were included in the current study. Cases from ileal conduit samples were excluded. A semiquantitative numerical scoring system (apoptotic index) was used to assess the amount of pyknosis or karyorrhexis, with 0 indicating none, 1 indicating < 10 per 10 high-power fields, 2 indicating 10 to 30 per 10 high-power fields, and 3 indicating > 30 per 10 high-power fields. Statistical analysis using the Pearson chi-square test was performed. A total of 228 cases including 105 benign cases, 79 cases of HGUC, and 44 cases of low-grade urothelial carcinoma (LGUC) diagnosed on follow-up surgical pathology were selected. A score of 0 was observed in 70 benign, 11 HGUC, and 8 LGUC cases; a score of 1 was observed in 31 benign, 21 HGUC, and 23 LGUC cases; a score of 2 was observed in 3 benign, 27 HGUC, and 9 LGUC cases; and a score of 3 was observed in 1 benign, 20 HGUC, and 4 LGUC cases. Excluding ileal conduit urine specimens, the finding of a high apoptotic index (score ≥ 2) with the presence of pyknosis or karyorrhexis in ≥10 per 10 high-power fields in the urine cytology appears to be significantly associated with HGUC (P<.05). Cancer Cytopathol 2016;124:546-51. © 2016 American Cancer Society. © 2016 American Cancer Society.
Peci, Adriana; Winter, Anne-Luise; Gubbay, Jonathan B.
2016-01-01
Legionella is a Gram-negative bacterium that can cause Pontiac fever, a mild upper respiratory infection and Legionnaire’s disease, a more severe illness. We aimed to compare the performance of urine antigen, culture, and polymerase chain reaction (PCR) test methods and to determine if sputum is an acceptable alternative to the use of more invasive bronchoalveolar lavage (BAL). Data for this study included specimens tested for Legionella at Public Health Ontario Laboratories from 1st January, 2010 to 30th April, 2014, as part of routine clinical testing. We found sensitivity of urinary antigen test (UAT) compared to culture to be 87%, specificity 94.7%, positive predictive value (PPV) 63.8%, and negative predictive value (NPV) 98.5%. Sensitivity of UAT compared to PCR was 74.7%, specificity 98.3%, PPV 77.7%, and NPV 98.1%. Out of 146 patients who had a Legionella-positive result by PCR, only 66 (45.2%) also had a positive result by culture. Sensitivity for culture was the same using either sputum or BAL (13.6%); sensitivity for PCR was 10.3% for sputum and 12.8% for BAL. Both sputum and BAL yield similar results regardless testing methods (Fisher Exact p-values = 1.0, for each test). In summary, all test methods have inherent weaknesses in identifying Legionella; therefore, more than one testing method should be used. Obtaining a single specimen type from patients with pneumonia limits the ability to diagnose Legionella, particularly when urine is the specimen type submitted. Given ease of collection and similar sensitivity to BAL, clinicians are encouraged to submit sputum in addition to urine when BAL submission is not practical from patients being tested for Legionella. PMID:27630979
Performance evaluation of three on-site adulterant detection devices for urine specimens.
Peace, Michelle R; Tarnai, Lisa D
2002-10-01
The performance of three on-site adulterant detection devices that assess the integrity of urine specimens collected for drug-of-abuse testing was evaluated: the Intect 7, MASK Ultra Screen, and Adultacheck 4. Intect 7 simultaneously tests creatinine, nitrite, glutaraldehyde, pH, specific gravity, and the presence of bleach and pyridinium chlorochromate (PCC). Mask Ultra Screen tests creatinine, nitrite, pH, specific gravity, and oxidants, and Adultacheck 4 tests creatinine, nitrite, glutaraldehyde, and pH. Urine specimens were prepared with the Substance Abuse and Mental Health Administration regulated analytes at 50% above the cut-off concentrations. Stealth, Urine Luck, Instant Clean ADD-IT-ive, and KLEAR were added individually to the drug-added urine specimens so that their concentrations reflected the "optimum" usage reported in their package inserts and 25% above and below that optimum. Stealth is reported to be peroxidase; Urine Luck is believed to be PCC; Instant Clean ADD-it-ive reportedly contains glutaraldehyde, and Klear is a nitrite. The following diluents/adulterants were added at 25%, 33%, and 50% of the volume of drug-added urine: distilled water, bleach, ammonia, and vinegar. Of the devices tested, Intect 7 proved to be the most sensitive, and it correctly indicated the presence of adulterant or diluent in all samples tested. In order to do so, all indication pads had to be assessed in concert. Adultacheck 4 specifically assesses four characteristics of urine integrity and is therefore very limited in detecting the use of several popular adulterants that are commercially available. Although it correctly assessed the four characteristics, it did not detect the use of Stealth, Urine Luck, or Instant Clean ADD-it-ive. Mask Ultra Screen can potentially detect a broader range of adulterants than Adultacheck 4. However, in practice, it only detected them at levels well above their optimum usage, making it less efficacious than Intect 7. Clearly, the specific identification of an adulterant is a trade-off for sensitive detection of several adulterants.
Trace drug analysis by surface-enhanced Raman spectroscopy
NASA Astrophysics Data System (ADS)
Farquharson, Stuart; Lee, Vincent Y.
2000-12-01
Drug overdose involves more than 10 percent of emergency room (ER) cases, and a method to rapidly identify and quantify the abused drug is critical to the ability of the ER physician to administer the appropriate care. To this end, we have been developing a surface-enhanced Raman (SER) active material capable of detecting target drugs at physiological concentrations in urine. The SER-active material consists of a metal-doped sol-gel that provides not only a million fold increase in sensitivity but also reproducible measurements. The porous silica network offers a unique environment for stabilizing SER active metal particles and the high surface area increase the interaction between the analyte and metal particles. The sol-gel has been coated on the inside walls of glass samples vials, such that urine specimens may simply be introduced for analysis. Here we present the surface-enhanced Raman spectra of a series of barbiturates, actual urine specimens, and a drug 'spiked' urine specimen. The utility of pH adjustment to suppress dominant biochemicals associated with urine is also presented.
CHROMagar Orientation Medium Reduces Urine Culture Workload
Manickam, Kanchana; Karlowsky, James A.; Adam, Heather; Lagacé-Wiens, Philippe R. S.; Rendina, Assunta; Pang, Paulette; Murray, Brenda-Lee
2013-01-01
Microbiology laboratories continually strive to streamline and improve their urine culture algorithms because of the high volumes of urine specimens they receive and the modest numbers of those specimens that are ultimately considered clinically significant. In the current study, we quantitatively measured the impact of the introduction of CHROMagar Orientation (CO) medium into routine use in two hospital laboratories and compared it to conventional culture on blood and MacConkey agars. Based on data extracted from our Laboratory Information System from 2006 to 2011, the use of CO medium resulted in a 28% reduction in workload for additional procedures such as Gram stains, subcultures, identification panels, agglutination tests, and biochemical tests. The average number of workload units (one workload unit equals 1 min of hands-on labor) per urine specimen was significantly reduced (P < 0.0001; 95% confidence interval [CI], 0.5326 to 1.047) from 2.67 in 2006 (preimplementation of CO medium) to 1.88 in 2011 (postimplementation of CO medium). We conclude that the use of CO medium streamlined the urine culture process and increased bench throughput by reducing both workload and turnaround time in our laboratories. PMID:23363839
[Measles pathogenic surveillance from 2005 to 2007 in Guangdong Province].
Liu, Leng; Zheng, Huan-ying; Guo, Xue; Zhu, Jian-qiong; Ji, Yi-xin; Xu, Wen-bo
2008-12-01
To develop pathogenic surveillance on measles and to effectively isolate measles virus. To know the genetic characterizations and molecular epidemiology of wildtype measles viruses from 2005 to 2007 in Guangdong Province, and provide the scientific basis for measles control and eradication. Vero/Slam cell line were used, measles viruses were isolated from throat swabs or urine specimens collected from uspected measles patients in outbreaks and sporadic patients. A 450 nucleotides fragment of the C-terminal of the nucleoprotein (N) gene was amplified and by RT-PCR and subjected to sequence and phylogenetic analysis using Bio-Edit software. 82 wild-type measels virus were obtained from 377 throat swabs and urine specimens from 2005 to 2007 in Guangdong Province measles lab. The measles isolation rate was 23.58% in 2005, 17.11% in 2006, 39.13% in 2007. The succeed rate of virus isolation is related to the quality of specimens collected and the days after rash occurrence. We have grasped the technicalability of measles virus isolation and confirm action, and got higher isolation ratio. The wild-type measles virus isolated from Guangdong Province is of H1 genotype from 2005 to 2007, which is the same as the dominant genotype circulation.
Tan, Susanna K; Sahoo, Malaya K; Milligan, Stephen B; Taylor, Nathaniel; Pinsky, Benjamin A
2017-10-01
Detection of Zika virus (ZIKV) RNA in urine is of increasing interest for the diagnosis of ZIKV infection. Pre-analytical variables can significantly impact the stability of RNA in urine. To determine optimal specimen processing protocols that would maximize detection of ZIKV RNA in urine by real-time, reverse transcriptase PCR, we investigated the effect of temperature, initial ZIKV concentration, use of nucleic acid stabilizers, and time on ZIKV RNA levels. Urine samples from healthy donors were spiked with ZIKV using the Exact Diagnostics ® ZIKV Verification Panel, a commercially available panel composed of heat-inactivated ZIKV, at concentrations of 5.0 log 10 copies/mL (ZIKV-high) and 4.0 log 10 copies/mL (ZIKV-low). Samples were stored at room temperature, 4°C, or -80°C and frozen aliquots were exposed to no stabilizer (urine), Buffer ATL (Qiagen, Germantown, MD), or DNA/RNA Shield (Zymo Research, Irvine, CA). ZIKV RNA levels in urine declined steadily at room temperature, though was not significant by 48h (ZIKV-high, p=0.09; ZIKV-low, p=0.20). ZIKV RNA titers were consistently higher when stored at 4°C, suggesting that storage at 4°C can slow the progression of RNA degradation. Freezing urine samples at -80°C resulted in a significant loss of detectable ZIKV RNA in the ZIKV-low group. ZIKV RNA was detected in 5/6 replicates at 3days, 1/6 replicates at 10days, and 1/3 replicates at 30days, with findings reproducible on repeat testing. Presence of either nucleic acid stabilizer in urine corrected this effect, and resulted in recovery of ZIKV RNA in all replicates. Use of a nucleic acid stabilizer in the ZIKV-high group did not add incremental benefit for the detection or quantitation of ZIKV RNA. ZIKV RNA is prone to degradation in urine with loss of detectable virus even when specimens are frozen at -80°C for 10days. Detection of ZIKV-positive urine samples, particularly those containing low ZIKV titers may be aided with the addition of a nucleic acid stabilizer during urine specimen processing. Copyright © 2017. Published by Elsevier B.V.
49 CFR 40.67 - When and how is a directly observed collection conducted?
Code of Federal Regulations, 2012 CFR
2012-10-01
... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.67 When and how is a... employee urinate into the collection container. Specifically, you are to watch the urine go from the...
49 CFR 40.67 - When and how is a directly observed collection conducted?
Code of Federal Regulations, 2013 CFR
2013-10-01
... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.67 When and how is a... employee urinate into the collection container. Specifically, you are to watch the urine go from the...
49 CFR 40.67 - When and how is a directly observed collection conducted?
Code of Federal Regulations, 2014 CFR
2014-10-01
... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.67 When and how is a... employee urinate into the collection container. Specifically, you are to watch the urine go from the...
Normalization of urinary pteridines by urine specific gravity for early cancer detection.
Burton, Casey; Shi, Honglan; Ma, Yinfa
2014-08-05
Urinary biomarkers, such as pteridines, require normalization with respect to an individual's hydration status and time since last urination. Conventional creatinine-based corrections are affected by a multitude of patient factors whereas urine specific gravity (USG) is a bulk specimen property that may better resist those same factors. We examined the performance of traditional creatinine adjustments relative to USG to six urinary pteridines in aggressive and benign breast cancers. 6-Biopterin, neopterin, pterin, 6-hydroxymethylpterin, isoxanthopterin, xanthopterin, and creatinine were analyzed in 50 urine specimens with a previously developed liquid chromatography-tandem mass spectrometry technique. Creatinine and USG performance were evaluated with non-parametric Mann-Whitney hypothesis testing. USG and creatinine were moderately correlated (r=0.857) with deviations occurring in dilute and concentrated specimens. In 48 aggressive and benign breast cancers, normalization by USG significantly outperformed creatinine adjustments which marginally outperformed uncorrected pteridines in predicting pathological status. In addition, isoxanthopterin and xanthopterin were significantly higher in pathological specimens when normalized by USG. USG, as a bulk property, can provide better performance over creatinine-based normalizations for urinary pteridines in cancer detection applications. Copyright © 2014 Elsevier B.V. All rights reserved.
Emerson, Jane F; Emerson, Scott S
2005-01-01
A standardized urinalysis and manual microscopic cell counting system was evaluated for its potential to reduce intra- and interoperator variability in urine and cerebrospinal fluid (CSF) cell counts. Replicate aliquots of pooled specimens were submitted blindly to technologists who were instructed to use either the Kova system with the disposable Glasstic slide (Hycor Biomedical, Inc., Garden Grove, CA) or the standard operating procedure of the University of California-Irvine (UCI), which uses plain glass slides for urine sediments and hemacytometers for CSF. The Hycor system provides a mechanical means of obtaining a fixed volume of fluid in which to resuspend the sediment, and fixes the volume of specimen to be microscopically examined by using capillary filling of a chamber containing in-plane counting grids. Ninety aliquots of pooled specimens of each type of body fluid were used to assess the inter- and intraoperator reproducibility of the measurements. The variability of replicate Hycor measurements made on a single specimen by the same or different observers was compared with that predicted by a Poisson distribution. The Hycor methods generally resulted in test statistics that were slightly lower than those obtained with the laboratory standard methods, indicating a trend toward decreasing the effects of various sources of variability. For 15 paired aliquots of each body fluid, tests for systematically higher or lower measurements with the Hycor methods were performed using the Wilcoxon signed-rank test. Also examined was the average difference between the Hycor and current laboratory standard measurements, along with a 95% confidence interval (CI) for the true average difference. Without increasing labor or the requirement for attention to detail, the Hycor method provides slightly better interrater comparisons than the current method used at UCI. Copyright 2005 Wiley-Liss, Inc.
Price, James
2015-01-01
Propoxyphene was withdrawn from the US market in November 2010. This drug is still tested for in the workplace as part of expanded panel nonregulated testing. A convenience sample of urine specimens (n = 7838) were provided by workers from various industries. The percentage of positive specimens with 95% confidence intervals was calculated for each year of the study. Logistic regression was used to assess the impact of the year upon the propoxyphene result. The prevalence of positive propoxyphene tests was much higher before the product's withdrawal from the market. Logistic regression provided evidence of a decreasing linear trend (P < 0.000; β = -0.71). The odds ratio signifies that for every additional year the urine specimens were 0.49 times less likely to be positive for propoxyphene. This favors the determination that the change in propoxyphene positive drug test over the years is not by chance. The conclusion supports no longer performing nonregulated workplace propoxyphene urine drug testing for this population.
Huang, Bin; Zhang, Lei; Zhang, Weizheng; Liao, Kang; Zhang, Shihong; Zhang, Zhiquan; Ma, Xingyan; Chen, Jialong; Zhang, Xiuhong; Qu, Pinghua; Wu, Shangwei
2017-01-01
ABSTRACT Rapid and accurate detection and identification of microbial pathogens causing urinary tract infections allow prompt and specific treatment. We optimized specimen processing to maximize the limit of detection (LOD) by matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) and evaluated the capacity of combination of MALDI-TOF MS and urine analysis (UA) for direct detection and identification of bacterial pathogens from urine samples. The optimal volumes of processed urine, formic acid/acetonitrile, and supernatant spotted onto the target plate were 15 ml, 3 μl, and 3 μl, respectively, yielding a LOD of 1.0 × 105 CFU/ml. Among a total of 1,167 urine specimens collected from three hospital centers, 612 (52.4%) and 351 (30.1%) were, respectively, positive by UA and urine culture. Compared with a reference method comprised of urine culture and 16S rRNA gene sequencing, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MALDI-TOF MS alone and MALDI-TOF MS coupled with UA were 86.6% versus 93.4% (χ2 = 8.93; P < 0.01), 91.5% versus 96.3% (χ2 = 7.06; P < 0.01), 81.5% versus 96.4% (χ2 = 37.32; P < 0.01), and 94.1% versus 93.1% (χ2 = 0.40; P > 0.05), respectively. No significant performance differences were revealed among the three sites, while specificity and NPV of MALDI-TOF MS for males were significantly higher than those for females (specificity, 94.3% versus 77.3%, χ2 = 44.90, P < 0.01; NPV, 95.5% versus 86.1%, χ2 = 18.85, P < 0.01). Our results indicated that the optimization of specimen processing significantly enhanced analytical sensitivity and that the combination of UA and MALDI-TOF MS provided an accurate and rapid detection and identification of bacterial pathogens directly from urine. PMID:28249997
Huang, Bin; Zhang, Lei; Zhang, Weizheng; Liao, Kang; Zhang, Shihong; Zhang, Zhiquan; Ma, Xingyan; Chen, Jialong; Zhang, Xiuhong; Qu, Pinghua; Wu, Shangwei; Chen, Cha; Tang, Yi-Wei
2017-05-01
Rapid and accurate detection and identification of microbial pathogens causing urinary tract infections allow prompt and specific treatment. We optimized specimen processing to maximize the limit of detection (LOD) by matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) and evaluated the capacity of combination of MALDI-TOF MS and urine analysis (UA) for direct detection and identification of bacterial pathogens from urine samples. The optimal volumes of processed urine, formic acid/acetonitrile, and supernatant spotted onto the target plate were 15 ml, 3 μl, and 3 μl, respectively, yielding a LOD of 1.0 × 10 5 CFU/ml. Among a total of 1,167 urine specimens collected from three hospital centers, 612 (52.4%) and 351 (30.1%) were, respectively, positive by UA and urine culture. Compared with a reference method comprised of urine culture and 16S rRNA gene sequencing, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MALDI-TOF MS alone and MALDI-TOF MS coupled with UA were 86.6% versus 93.4% (χ 2 = 8.93; P < 0.01), 91.5% versus 96.3% (χ 2 = 7.06; P < 0.01), 81.5% versus 96.4% (χ 2 = 37.32; P < 0.01), and 94.1% versus 93.1% (χ 2 = 0.40; P > 0.05), respectively. No significant performance differences were revealed among the three sites, while specificity and NPV of MALDI-TOF MS for males were significantly higher than those for females (specificity, 94.3% versus 77.3%, χ 2 = 44.90, P < 0.01; NPV, 95.5% versus 86.1%, χ 2 = 18.85, P < 0.01). Our results indicated that the optimization of specimen processing significantly enhanced analytical sensitivity and that the combination of UA and MALDI-TOF MS provided an accurate and rapid detection and identification of bacterial pathogens directly from urine. Copyright © 2017 American Society for Microbiology.
Bogoch, Isaac I; Andrews, Jason R; Dadzie Ephraim, Richard K; Utzinger, Jürg
2012-10-01
To evaluate the utility of a simple questionnaire and urine reagent strip testing for the rapid diagnosis of Schistosoma haematobium in rural northern Ghana. Cross-sectional parasitological and questionnaire survey in a community in northern Ghana. Participants provided two urine specimens that were examined under a microscope using a centrifugation method. The first urine sample was additionally subjected to reagent strip testing. A short questionnaire was administered to all participants. Microscopy of urine samples obtained from 208 individuals aged 1-77 years revealed an S. haematobium prevalence of 6.8%. The presence of any blood or protein on a urine reagent strip was 100% and 42% sensitive, and 93% and 80% specific for S. haematobium diagnosis. Questionnaires were completed by 198 individuals. Self-reported haematuria showed a sensitivity of 53% and a specificity of 85%. A dichotomous two-question panel was helpful in S. haematobium diagnosis, with working and playing near the river significantly associated with S. haematobium infection (P < 0.001). The use of urine reagent strips, coupled with questions pertaining to water contact patterns, might be considered for point-of-contact diagnosis of S. haematobium where microscopy is unavailable. © 2012 Blackwell Publishing Ltd.
Code of Federal Regulations, 2010 CFR
2010-10-01
...) If the employee refuses to make the attempt to provide a new urine specimen or leaves the collection site before the collection process is complete, you must discontinue the collection, note the fact on... attempt to provide the specimen, you must discontinue the collection, note the fact on the “Remarks” line...
Pasteurella aerogenes as an Asymptomatic Bacteriuria Agent.
Alaygut, Demet; Engin, Aynur
2018-02-01
'Asymptomatic bacteriuria' (ASB) is isolation of a specified quantitative count of bacteria in an appropriately collected urine specimen obtained from a person without symptoms or signs referable to urinary infection. Catheterized specimens are less likely to be contaminated compared with voided specimens; therefore, positive cultures of catheterized specimens are more likely to reflect true bladder bacteriuria even with low colony counts. The common pathogens for ASB are Escherichia coli, Klebsiella and Streptococcus spp. Pasteurella spp. was not previously reported as an ASB agent. ASB is important for pregnant women, children, individuals with obstructive uropathy, chronic renal failure and neutropenia, before the urologic procedures and after renal transplantation. Treatment of ASB is required for above situations. We report an 11-year-old-girl with neurogenic bladder who made clean intermittent catheterization and had Pasteurella aerogenes as an ASB agent. © The Author [2017]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
The preservation of urine samples for determination of renal stone risk factors
NASA Technical Reports Server (NTRS)
Nicar, M. J.; Hsu, M. C.; Johnson, T.; Pak, C. Y.
1987-01-01
A preservation technique for urine specimens before determination of stone risk factors was evaluated. The purpose of these experiments was to prove the effectiveness of the preservatives used to prevent changes in the concentrations of those constituents measured. Measured concentrations in fresh specimens were compared with those in the same specimens after storage with the preservatives. Refrigeration at 4 degrees C up to five days was appropriate in a laboratory setting, as no significant changes in urinary concentrations occurred. Refrigeration, however, did not offer a convenient method for shipping. Chemical preservation was found to be an effective alternative to refrigeration. Thymol prevented changes in concentration of pH, citrate, uric acid, sulfate, sodium, potassium, and cyclic AMP, while a mixture of hydrochloric (HCl) acid and boric acid prevented changes in calcium, magnesium, phosphorus, oxalate, ammonium, and creatinine. Thus, the addition of thymol or HCl/boric acid to urine specimens will prevent significant changes in the concentrations of stone risk factors.
Use of Urine Biomarkers to Assess Sodium Intake: Challenges and Opportunities
Maalouf, Joyce; Elliott, Paul; Loria, Catherine M.; Patel, Sheena; Bowman, Barbara A.
2017-01-01
This article summarizes current data and approaches to assess sodium intake in individuals and populations. A review of the literature on sodium excretion and intake estimation supports the continued use of 24-h urine collections for assessing population and individual sodium intake. Since 2000, 29 studies used urine biomarkers to estimate population sodium intake, primarily among adults. More than half used 24-h urine; the rest used a spot/casual, overnight, or 12-h specimen. Associations between individual sodium intake and health outcomes were investigated in 13 prospective cohort studies published since 2000. Only three included an indicator of long-term individual sodium intake, i.e., multiple 24-h urine specimens collected several days apart. Although not insurmountable, logistic challenges of 24-h urine collection remain a barrier for research on the relationship of sodium intake and chronic disease. Newer approaches, including modeling based on shorter collections, offer promise for estimating population sodium intake in some groups. PMID:25974702
De, Prithwiraj; Amin, Anita G.; Valli, Eloise; Perkins, Mark D.; McNeil, Michael; Chatterjee, Delphi
2015-01-01
Globally, tuberculosis is slowly declining each year and it is estimated that 37 million lives were saved between 2000 and 2013 through effective diagnosis and treatment. Currently, diagnosis relies on demonstration of the bacteria, Mycobacterium tuberculosis (Mtb), in clinical specimens by serial sputum microscopy, culture and molecular testing. Commercial immunoassay lateral flow kits developed to detect Mtb lipoglycan lipoarabinomannan (LAM) in urine as a marker of active TB exhibit poor sensitivity, especially in immunocompetent individuals, perhaps due to low abundance of the analyte. Our present study was designed to develop methods to validate the presence of LAM in a quantitative fashion in human urine samples obtained from culture-confirmed TB patients. Herein we describe, a consolidated approach for isolating LAM from the urine and quantifying D-arabinose as a proxy for LAM, using Gas Chromatography/Mass Spectrometry. 298 urine samples obtained from a repository were rigorously analyzed and shown to contain varying amounts of LAM-equivalent ranging between ~10–40 ng/mL. To further substantiate that D-arabinose detected in the samples originated from LAM, tuberculostearic acid, the unique 10-methyloctadecanoic acid present at the phosphatidylinositol end of LAM was also analyzed in a set of samples and found to be present confirming that the D-arabinose was indeed derived from LAM. Among the 144 samples from culture-negative TB suspects, 30 showed presence of D-arabinose suggesting another source of the analyte, such as disseminated TB or from non-tuberculosis mycobacterium. Our work validates that LAM is present in the urine samples of culture-positive patients in small but readily detectable amounts. The study further substantiates LAM in urine as a powerful biomarker for active tuberculosis. PMID:26633829
ERIC Educational Resources Information Center
Webb, Marquitta C.; Salandy, Sinead T.; Beckford, Safiya E.
2016-01-01
Objective: To investigate the hydration status pre- and post-training among university athletes using urine color and weight loss as indicators. Participants: Participants were 52 university athletes training for campus games in a developing country. Methods: Pre- and post-training urine specimens were compared with a standard urine color scale.…
Blasi, Maria; Carpenter, J Harris; Balakumaran, Bala; Cara, Andrea; Gao, Feng; Klotman, Mary E
2015-08-24
HIV-1 persists indefinitely in memory CD4 T cells and other long-lived cellular reservoirs despite antiretroviral therapy. Our group had previously demonstrated that HIV-1 can establish a productive infection in renal epithelial cells and that the kidney represents a separate compartment for HIV-1 replication. Here, to better understand the viruses in this unique site, we genetically characterized and compared the viruses in blood and urine specimens from 24 HIV-1 infected patients with detectable viremia. Blood and urine samples were obtained from 35 HIV-1 positive patients. Single-genome amplification was performed on HIV-1 env RNA and DNA isolated from urine supernatants and urine-derived cell pellets, respectively, as well as from plasma and peripheral blood mononuclear cell from the same individuals. Neighbor-joining trees were constructed under the Kimura 2-parameter model. We amplified and sequenced the full-length HIV-1 envelope (env) gene from 12 of the 24 individuals, indicating that 50% of the viremic HIV-1-positive patients had viral RNA in their urine. Phylogenetic analysis of the env sequences from four individuals with more than 15 urine-derived env sequences showed that the majority of the sequences from urine formed distinct cluster(s) independent of those peripheral blood mononuclear cell and plasma-derived sequences, consistent with viral compartmentalization in the urine. Our results suggest the presence of a distinct HIV compartment in the genitourinary tract.
BLASI, Maria; CARPENTER, J. Harris; BALAKUMARAN, Bala; CARA, Andrea; GAO, Feng; KLOTMAN, Mary E.
2015-01-01
Objective HIV-1 persists indefinitely in memory CD4+ T cells and other long-lived cellular reservoirs despite antiretroviral therapy (ART). Our group had previously demonstrated that HIV-1 can establish a productive infection in renal epithelial cells and that the kidney represents a separate compartment for HIV-1 replication. Here, to better understand the viruses in this unique site, we genetically characterized and compared the viruses in blood and urine specimens from twenty-four HIV-1 infected subjects with detectable viremia. Design and Methods Blood and urine samples were obtained from 35 HIV-1 positive subjects. Single-genome amplification was performed on HIV-1 env RNA and DNA isolated from urine supernatants and urine derived cell pellets respectively, as well as from plasma and PBMC from the same individuals. Neighbor-joining trees were constructed under the Kimura 2-parameter mode. Results We amplified and sequenced the full-length HIV-1 envelope (env) gene from twelve of the twenty-four individuals, indicating that fifty percent (50%) of the viremic HIV-1 positive patients had viral RNA in their urine. Phylogenetic analysis of the env sequences from four subjects with more than fifteen urine-derived env sequences showed that the majority of the sequences from urine formed distinct cluster(s) independent of those PBMC and plasma-derived sequences, consistent with viral compartmentalization in the urine. Conclusions Our results suggest the presence of a distinct HIV compartment in the genitourinary tract. PMID:26372275
Importance of sample preparation for molecular diagnosis of lyme borreliosis from urine.
Bergmann, A R; Schmidt, B L; Derler, A-M; Aberer, E
2002-12-01
Urine PCR has been used for the diagnosis of Borrelia burgdorferi infection in recent years but has been abandoned because of its low sensitivity and the irreproducibility of the results. Our study aimed to analyze technical details related to sample preparation and detection methods. Crucial for a successful urine PCR were (i) avoidance of the first morning urine sample; (ii) centrifugation at 36,000 x g; and (iii) the extraction method, with only DNAzol of the seven different extraction methods used yielding positive results with patient urine specimens. Furthermore, storage of frozen urine samples at -80 degrees C reduced the sensitivity of a positive urine PCR result obtained with samples from 72 untreated erythema migrans (EM) patients from 85% in the first 3 months to <30% after more than 3 months. Bands were detected at 276 bp on ethidium bromide-stained agarose gels after amplification by a nested PCR. The specificity of bands for 32 of 33 samples was proven by hybridization with a GEN-ETI-K-DEIA kit and for a 10 further positive amplicons by sequencing. By using all of these steps to optimize the urine PCR technique, B. burgdorferi infection could be diagnosed by using urine samples from EM patients with a sensitivity (85%) substantially better than that of serological methods (50%). This improved method could be of future importance as an additional laboratory technique for the diagnosis of unclear, unrecognized borrelia infections and diseases possibly related to Lyme borreliosis.
Passive inhalation of cocaine.
Cone, E J; Yousefnejad, D; Hillsgrove, M J; Holicky, B; Darwin, W D
1995-10-01
Six healthy male volunteers were exposed to the vapor of 100 and 200 mg freebase cocaine heated to a temperature of 200 degrees C in an unventilated room (12,600-L volume) for a period of 1 h. No pharmacological effects were detected as a result of the exposure. Blood specimens collected immediately following exposure were negative for cocaine and metabolites. Urine specimens analyzed by gas chromatography-mass spectrometry contained peak concentrations of benzoylecgonine that ranged from 22 to 123 ng/mL. The peak excretion time for benzoylecgonine following passive exposure was approximately 5 h. The amount of cocaine inhaled by the subjects during passive exposure was estimated from room air measurements of cocaine to be approximately 0.25 mg. The total amount of cocaine (cocaine plus metabolites) excreted in urine by the six subjects ranged from 0.04 to 0.21 mg. For comparison, the six subjects also received an intravenous injection of 1 mg cocaine hydrochloride. Four of six subjects screened positive (300-ng/mL cutoff concentration) following the injection, indicating that the minimum amount of cocaine in these subjects necessary to produce positive results was approximately 1 mg. A second passive inhalation study was undertaken in which specimens were collected from research staff who assisted in a series of experimental studies with "crack" (freebase cocaine) smokers. The research staff remained in close vicinity while the crack smokers smoked three doses of freebase cocaine (12.5, 25, and 50 mg) over a period of 4 h. As a result, staff members were passively exposed to sidestream smoke from crack pipes and to breath exhalation from the crack smokers. Urine specimens from the staff members contained a maximum of 6 ng/mL benzoylecgonine. Only traces (less than 1 ng/mL) of cocaine were detected in any specimen. Overall, these studies demonstrated that individuals exposed to cocaine smoke under naturalistic or artificial conditions absorbed small amounts of cocaine that were insufficient to produce positive urine specimens at standard Department of Health and Human Services cutoffs. However, passive exposure conditions that would result in absorption of cocaine in amounts exceeding 1 mg could result in the production of cocaine-positive urine specimens.
Shah, Ami P; Cobb, Benjamin T; Lower, Darla R; Shaikh, Nader; Rasmussen, Jayne; Hoberman, Alejandro; Wald, Ellen R; Rosendorff, Adam; Hickey, Robert W
2014-03-01
Urinary tract infections (UTI) are the most common serious bacterial infection in febrile infants. Urinalysis (UA) is a screening test for preliminary diagnosis of UTI. UA can be performed manually or using automated techniques. We sought to compare manual versus automated UA for urine specimens obtained via catheterization in the pediatric emergency department. In this prospective study, we processed catheterized urine samples from infants with suspected UTI by both the manual method (enhanced UA) and the automated method. We defined a positive enhanced UA as ≥ 10 white blood cells per cubic millimeter and presence of any bacteria per 10 oil immersion fields on a Gram-stained smear. We defined a positive automated UA as ≥ 2 white blood cells per high-powered field and presence of any bacteria using the IRIS iQ200 ELITE. We defined a positive urine culture as growth of ≥ 50,000 colony-forming units per milliliter of a single uropathogen. We analyzed data using SPSS software. A total of 703 specimens were analyzed. Prevalence of UTI was 7%. For pyuria, the sensitivity and positive predictive value (PPV) of the enhanced UA in predicting positive urine culture were 83.6% and 52.5%, respectively; corresponding values for the automated UA were 79.5% and 37.5%, respectively. For bacteriuria, the sensitivity and PPV of a Gram-stained smear (enhanced UA) were 83.6% and 59.4%, respectively; corresponding values for the automated UA were 73.4%, and 26.2%, respectively. Using criteria of both pyuria and bacteriuria for the enhanced UA resulted in a sensitivity of 77.5% and a PPV of 84.4%; corresponding values for the automated UA were 63.2% and 51.6%, respectively. Combining automated pyuria (≥ 2 white blood cells/high-powered microscopic field) with a Gram-stained smear resulted in a sensitivity of 75.5% and a PPV of 84%. Automated UA is comparable with manual UA for detection of pyuria in young children with suspected UTI. Bacteriuria detected by automated UA is less sensitive and specific for UTI when compared with a Gram-stained smear. We recommend using either manual or automated measurement of pyuria in combination with Gram-stained smear as the preferred technique for UA of catheterized specimens obtained from children in an acute care setting.
Lunny, Carole; Taylor, Darlene; Hoang, Linda; Wong, Tom; Gilbert, Mark; Lester, Richard; Krajden, Mel; Ogilvie, Gina
2015-01-01
Background The increases in STI rates since the late 1990s in Canada have occurred despite widespread primary care and targeted public health programs and in the setting of universal health care. More innovative interventions are required that would eliminate barriers to STI testing such as internet-based or mail-in home and community service testing for patients that are hard to reach, who refuse to go for clinician-based testing, or who decline an examination. Jurisdictions such as New Zealand and some American states currently use self-collected sampling, but without the required evidence to determine whether self-collected specimens are as accurate as clinician-collected specimens in terms of chlamydia and gonorrhea diagnostic accuracy. The objective of the review is to compare self-collected vaginal, urine, pharyngeal and rectal samples to our reference standard - clinician-collected cervical, urethral, pharyngeal and rectal sampling techniques to identify a positive specimen using nucleic acid amplification test assays. Methods The hierarchical summary receiver operating characteristic and the fixed effect models were used to assess the accuracy of comparable specimens that were collected by patients compared to clinicians. Sensitivity and specificity estimates with 95% confidence intervals (CI) were reported as our main outcome measures. Findings We included 21 studies based on over 6100 paired samples. Fourteen included studies examined chlamydia only, 6 compared both gonorrhea and chlamydia separately in the same study, and one examined gonorrhea. The six chlamydia studies comparing self-collection by vaginal swab to a clinician-collected cervical swab had the highest sensitivity (92%, 95% CI 87-95) and specificity (98%, 95% CI 97-99), compared to other specimen-types (urine/urethra or urine/cervix). Six studies compared urine self-samples to urethra clinician-collected samples in males and produced a sensitivity of 88% (95% CI 83-93) and a specificity of 99% (95% CI 0.94-0.99). Taking into account that urine samples may be less sensitive than cervical samples, eight chlamydia studies that compared urine self-collected verses clinician-collected cervical samples had a sensitivity of 87% (95% CI 81-91) and high specificity of 99% (95% CI 0.98-1.00). For gonorrhea testing, self-collected urine samples compared to clinician-collected urethra samples in males produced a sensitivity of 92% (95% CI 83-97) and specificity of 99% (95% CI 0.98-1.00). Conclusion The sensitivity and specificity of vaginal self-collected swabs compared to swabs collected by clinicians supports the use of vaginal swab as the recommended specimen of choice in home-based screening for chlamydia and gonorrhea. Urine samples for gonorrhea collected by men had comparably high sensitivity and specificity, so could be recommended as they can be left at room temperature for several days, allowing for the possibility of mail-in home-based testing. In populations that may not go for testing at all, do not have the option of clinical testing, or who refuse a clinical examination, self-collected screening would be a good alternative. We recommend that guidelines on how to self-collect gonorrhea and chlamydia urine, vaginal, rectal and pharyngeal specimens be published. PMID:26168051
10 CFR 26.105 - Preparing for urine collection.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Preparing for urine collection. 26.105 Section 26.105 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.105 Preparing for urine collection. (a) The collector shall ask the donor to remove any unnecessary outer...
10 CFR 26.105 - Preparing for urine collection.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Preparing for urine collection. 26.105 Section 26.105 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.105 Preparing for urine collection. (a) The collector shall ask the donor to remove any unnecessary outer...
10 CFR 26.105 - Preparing for urine collection.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Preparing for urine collection. 26.105 Section 26.105 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.105 Preparing for urine collection. (a) The collector shall ask the donor to remove any unnecessary outer...
10 CFR 26.105 - Preparing for urine collection.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Preparing for urine collection. 26.105 Section 26.105 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.105 Preparing for urine collection. (a) The collector shall ask the donor to remove any unnecessary outer...
10 CFR 26.105 - Preparing for urine collection.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Preparing for urine collection. 26.105 Section 26.105 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.105 Preparing for urine collection. (a) The collector shall ask the donor to remove any unnecessary outer...
Puet, Brandi; DePriest, Anne; Knight, Julie; Heltsley, Rebecca; Black, David L; Caplan, Yale H; Cone, Edward J
2013-01-01
Propoxyphene is an opioid analgesic that was surrounded by controversy concerning its safety and efficacy during its lifespan in the US market. Propoxyphene was withdrawn in November of 2010 from the US market and is still being detected one year post-withdrawal in urine specimens from the pain management population. In this study, the prevalence of propoxyphene was determined in a total of 417,914 urine specimens collected from 630 clinics involved in pain management located in 24 states during the period of January 1, 2010, through December 31, 2011. Propoxyphene and norpropoxyphene were measured in urine by a validated liquid chromatography-tandem mass spectrometry procedure with a lower limit of quantitation of 50 ng/mL. The positivity rate for propoxyphene prevalence declined sharply between November and December of 2010 and further declined at a gradual rate, ending in a prevalence of 0.27% (one out of every 370 specimens, n = 25,658) for the month of December 2011. The presented data provide evidence of the dramatic decline in the use of propoxyphene products since their removal from the medical market, and may be beneficial to US urine drug testing programs determining the need for continual monitoring of propoxyphene levels.
Fernández, Purificación; Fernández, Ana M; Bermejo, Ana M; Lorenzo, Rosa A; Carro, Antonia M
2013-04-01
The performance of microwave-assisted extraction and HPLC with photodiode array detection method for determination of six analgesic and anti-inflammatory drugs from plasma and urine, is described, optimized, and validated. Several parameters affecting the extraction technique were optimized using experimental designs. A four-factor (temperature, phosphate buffer pH 4.0 volume, extraction solvent volume, and time) hybrid experimental design was used for extraction optimization in plasma, and three-factor (temperature, extraction solvent volume, and time) Doehlert design was chosen to extraction optimization in urine. The use of desirability functions revealed the optimal extraction conditions as follows: 67°C, 4 mL phosphate buffer pH 4.0, 12 mL of ethyl acetate and 9 min, for plasma and the same volume of buffer and ethyl acetate, 115°C and 4 min for urine. Limits of detection ranged from 4 to 45 ng/mL in plasma and from 8 to 85 ng/mL in urine. The reproducibility evaluated at two concentration levels was less than 6.5% for both specimens. The recoveries were from 89 to 99% for plasma and from 83 to 99% for urine. The proposed method was successfully applied in plasma and urine samples obtained from analgesic users. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Comparison of daily urine, sweat, and skin swabs among cocaine users.
Kidwell, D A; Kidwell, J D; Shinohara, F; Harper, C; Roarty, K; Bernadt, K; McCaulley, R A; Smith, F P
2003-04-23
This study (1) compares urine, skin swabs, and PharmChek sweat patches for monitoring drug use; (2) measures possible environmental contamination in recent cocaine (COC) users; and (3) evaluates various immunoassays (IA) for screening COC in diverse matrices. Unique aspects include daily urine monitoring of 10 participants for 4 weeks, multiple monitoring methods, analysis for all specimens by IA and gas chromatography (GC)/mass spectrometry (MS), and the potential for continued illicit drug use by participants. Urine served as the "gold standard" specimen for determining drug use. Only cocaine and related substances were detected. Trace amounts of drugs were found on the skin (<50 ng per swab) of urine-negative participants' hands or forehead. In contrast, larger quantities of COC were found on the skin of individuals with BE-positive urines or individuals living with drug users (up to 20 microg per swab). Patch COC amounts among the three regular users (250-9000, 0-240, 160-22,000 ng per patch) exceeded BE (50-950, none, 30-2200 ng per patch). Pre-swabs, valuable for interpreting the source or time frame of positive patch results, contained substantial COC (38-1160, 0-152, 34-762 ng per swab) prior to patch application; therefore, patch results may represent current use, prior use, contamination, or a combination. In three individuals with no indication of cocaine use, false positives (defined as sweat patch positive when urine specimens were <300ng BE/ml) occurred at a 7% rate. Proposed cut-off concentrations of 75 ng cocaine per patch and 300 ng BE/ml urine curtail the incidence of false positives in this limited population. Three immunoassays were compared to screen specimens for cocaine: a modified, manual Microgenics CEDIA; a Cozart ELISA; and an OraSure ELISA. CEDIA's limit of detection (LOD) was 81ng/ml, compared with LODs of 4 ng/ml for the Cozart ELISA and 1.5 ng/ml for the OraSure ELISA. Cozart correlated with OraSure results for COC concentrations <2000 ng per swab (n=117), r(2)=0.79.
Nickel, J. Curtis; Stephens, Alisa; Landis, J. Richard; Chen, Jun; Mullins, Chris; van Bokhoven, Adrie; Lucia, M. Scott; Melton-Kreft, Rachael; Ehrlich, Garth D.
2015-01-01
Introduction We used next-generation, state-of-the-art, culture-independent methodology to survey urine microbiota of UCPPS males and control participants enrolled in the MAPP Network to investigate a possible microbial etiology. Methods Male UCPPS patients and matched controls were asked to provide VB1, VB2 and VB3 urine specimens. Specimens were analyzed with Ibis T-5000 Universal Biosensor technology to provide comprehensive identification of bacterial and select fungal species. Differences between UCPPS and control study participants for presence of species or species variation within a higher taxonomic grouping (genus) were evaluated using permutational multivariate analysis of variance and logistic regression. Results VB1 and VB2 urine specimens were obtained from 110 (VB3 in 67) UCPPS participants and 115 (VB3 in 62) controls. A total of 78, 73 and 54 species (42, 39 and 27 genera) were detected in VB1, VB2 and VB3 respectively. Mean (SD) VB1, VB2 and VB3 species count per person was 1.62 (1.28), 1.38 (1.36) and 1.33(1.24) for cases and 1.75(1.32), 1.23(1.15) and 1.56 (0.97) for controls respectively. Overall species and genus composition differed significantly between UCPPS and control participants in VB1 (p=0.002 species level, p=0.004 genus level) with Burkholderia cenocepacia over represented in UCPPS cases. No significant differences were observed at any level in VB2 or VB3 samples. Conclusions Assessment of baseline culture-independent microbiological data from male subjects enrolled in the MAPP Network has identified over representation of B cenocepacia in UCPPS. Future studies are planned to further evaluate microbiota associations with variable and changing UCPPS symptom patterns. PMID:25596358
Urinary Concentrating Ability in Women with Asymptomatic Bacteriuria in Pregnancy
Williams, G. L.; Campbell, H.; Davies, K. J.
1969-01-01
The incidence of impaired renal concentrating ability in pregnant women with asymptomatic significant bacteriuria is significantly less than previously reported when osmolality readings are performed on every urine specimen obtained during the 24 hours' deprivation of fluids. The concentrating defect is more considerable as pregnancy progresses. The lower the maximum urinary osmolality the more difficult is the treatment of the patient, and the higher the incidence of acute pyelonephritis. PMID:5792611
Moslah, B; Araoud, M; Nouioui, M A; Najjar, S; Amira, D; Ben Salah, N; Hedhili, A
2018-02-01
Forensic investigation performed on people suspected to be drug abusers covering all Tunisian cities was conducted by monitoring an epidemiological study of human urine samples surveying positive rates of consumption for drugs of abuse. The forensic investigations were conducted on a total of 28,298 arrested individuals suspected to be drug addicts during five years (January 2010-December 2015). An immunoassay screening tests to detect elevated levels of drugs classes in urine samples was performed. These screening assays provide a preliminary qualitative test result. Only positives urine specimens were analyzed with GC-MS for confirmation. Except for cannabis, the results showed insignificant number of positive cases for cocaine, ecstasy (MDMA) and amphetamine consumptions (<1%). Copyright © 2017 Elsevier B.V. All rights reserved.
Wang, X-H; Zhang, G; Fan, Y-Y; Yang, X; Sui, W-J; Lu, X-X
2013-03-01
Rapid identification of bacterial pathogens from clinical specimens is essential to establish an adequate empirical antibiotic therapy to treat urinary tract infections (UTIs). We used matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) combined with UF-1000i urine flow cytometry of urine specimens to quickly and accurately identify bacteria causing UTIs. We divided each urine sample into three aliquots for conventional identification, UF-1000i, and MALDI-TOF MS, respectively. We compared the results of the conventional method with those of MALDI-TOF MS combined with UF-1000i, and discrepancies were resolved by 16S rRNA gene sequencing. We analyzed 1456 urine samples from patients with UTI symptoms, and 932 (64.0%) were negative using each of the three testing methods. The combined method used UF-1000i to eliminate negative specimens and then MALDI-TOF MS to identify the remaining positive samples. The combined method was consistent with the conventional method in 1373 of 1456 cases (94.3%), and gave the correct result in 1381 of 1456 cases (94.8%). Therefore, the combined method described here can directly provide a rapid, accurate, definitive bacterial identification for the vast majority of urine samples, though the MALDI-TOF MS software analysis capabilities should be improved, with regard to mixed bacterial infection. Copyright © 2012 Elsevier B.V. All rights reserved.
Deng, G; Zhang, Y; Xiao, G
1995-09-01
For rapid diagnosis of systemic candidiasis, the polymerase chain reaction (PCR) was used to amplify a segment of Candida albican DNA coding for the cytochrome P450 L1 A1 in vitro. The technique provided unambiguous evidence of the presence of Candida albicans in as short as 8 hours with a detection threshold of 20 organisms. 200 blood and 120 urine specimens were collected from thirty rabbits with burn and candidiasis. Specimens of blood (n = 6), urine (n = 6), sputum (n = 7) and wound exudate (n = 7) were also collected from eight serious burn patients. PCR technique was used in all the specimens, and the result was compared with conventional fungus culture. It was shown that: (1) The positive detection rate of Candida by PCR was significantly higher than by culture for blood specimens (P < 0.01) and serial specimens of urine (P < 0.05) in infected burn animals. The clinical specimens showed the same results; (2) In evaluating diagnostic value of PCR for systemic Candida albicans infection, it was found that sensitivity, accuracy and negative prediction rate were superior to the conventional culture method. These results suggest that PCR technic may provide a rapid sensitive and specific means for the diagnosis of systemic Candida albicans infection. In addition, it may be helpful in the evaluation of therapeutic response or recurrence of infection.
Experience of the Manitoba Perinatal Screening Program, 1965-85.
Fox, J G
1987-01-01
The Manitoba Perinatal Screening Program is guided by a committee of medical specialists with skills in the diagnosis and management of disorders of metabolism in the newborn. The program is voluntary and is centralized at Cadham Provincial Laboratory, in Winnipeg. A filter card blood specimen is collected from newborns on discharge from hospital, and a filter card urine sample is collected and mailed to the laboratory by the mother when the infant is about 2 weeks of age. The overall compliance rates for the blood and urine specimens are approximately 100% and 84% respectively. The blood specimen is screened for phenylalanine and other amino acids, thyroxine, galactose, galactose-1-phosphate and biotinidase. The urine specimen is screened for amino acids, including cystine, as well as methylmalonic acid and homocystine. Between 1965 and 1985, 83 cases of metabolic disorders were detected, including 23 cases of primary hypothyroidism, 14 of classic phenylketonuria, 5 of galactosemia variants, 3 of galactosemia, 2 of maple syrup urine disease and 1 of hereditary tyrosinemia. The direct cost per infant screened is $5.50, and the cost:benefit ratio is approximately 7.5:1. Maternal serum alpha-fetoprotein screening is being made available as the necessary supporting clinical facilities become available. On the basis of this experience, the author outlines the components that are important for an effective screening program. PMID:3676929
Poklis, Justin L.; Clay, Deborah J.; Poklis, Alphonse
2014-01-01
We present a high-performance liquid chromatography triple quadrupole mass spectrometry (HPLC–MS-MS) method for the identification and quantification of nine serotonin 5-HT2A receptor agonist hallucinogenic substances from a new class of N-methoxybenzyl derivatives of methoxyphenylethylamine (NBOMe) designer drugs in human urine: 25H-NBOMe, 2CC-NBOMe, 25I-NBF, 25D-NBOMe, 25B-NBOMe, 2CT-NBOMe, 25I-NBMD, 25G-NBOMe and 25I-NBOMe. This assay was developed for the Virginia Commonwealth University Clinical and Forensic Toxicology laboratory to screen emergency department specimens in response to an outbreak of N-benzyl-phenethylamine derivative abuse and overdose cases in Virginia. The NBOMe derivatives were rapidly extracted from the urine specimens by use of FASt™ solid-phase extraction columns. Assay performance was determined as recommended for validation by the Scientific Working Group for Forensic Toxicology (SWGTOX) for linearity, lower limit of quantification, lower limit of detection, accuracy/bias, precision, dilution integrity, carryover, selectivity, absolute recovery, ion suppression and stability. Linearity was verified to be from 1 to 100 ng/mL for each of the nine analytes. The bias determined for the NBOMe derivatives was 86–116% with a <14% coefficient of variation over the linear range of the assay. Four different NBOMe derivatives were detected using the presented method in patient urine specimens. PMID:24535338
Monsen, Tor; Rydén, Patrik
2015-02-01
Urinary tract infections (UTIs) are the second most common bacterial infection. Urine culture is the gold standard for diagnosis, but new techniques, such as flow cytometry analysis (FCA), have been introduced. The aim of the present study was to evaluate FCA characteristics regarding bacteriuria, leukocyturia, and erythrocyturia in relation to cultured uropathogens in specimens from patients with a suspected UTI. We also wanted to evaluate whether the FCA characteristics can identify uropathogens prior to culture. From a prospective study, 1,587 consecutive urine specimens underwent FCA prior to culture during January and February 2012. Outpatients and inpatients (79.6% and 19.4%, respectively) were included, of whom women represented 67.5%. In total, 620 specimens yielded growth, of which Escherichia coli represented 65%, Enterococcus spp. 8%, Klebsiella spp. 7%, and Staphylococcus spp. 5%. For the uropathogens, the outcome of FCA was compared against the results for specimens with E. coli and those with a negative culture. E. coli had high bacterial (median, 17,914/μl), leukocyte (median, 348/μl), and erythrocyte (median, 23/μl) counts. With the exception of Klebsiella spp., the majority of the uropathogens had considerable or significantly lower bacterial counts than that of E. coli. High leukocyte counts were found in specimens with Staphylococcus aureus, Proteus mirabilis, Pseudomonas aeruginosa, and group C streptococci. Elevated erythrocyte counts were found for P. vulgaris, P. aeruginosa, and group C streptococci, as well as for Staphylococcus saprophyticus. In essence, FCA adds new information about the bacterial, leukocyte, and erythrocyte counts in urine specimens for different uropathogens. Based on FCA characteristics, uropathogens can be classified and identified prior to culture. E. coli and Klebsiella spp. have similar FCA characteristics. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Zinellu, Angelo; Sotgia, Salvatore; Zinellu, Elisabetta; Chessa, Roberto; Deiana, Luca; Carru, Ciriaco
2006-03-01
Guanidinoacetic acid (GAA) measurement has recently become of great interest for the diagnosis of creatine (Cn) metabolism disorders, and research calls for rapid and inexpensive methods for its detection in plasma and urine in order to assess a large number of patients. We propose a new assay for the measurement of GAA by a simple CZE UV-detection without previous sample derivatization. Plasma samples were filtered by Microcon-10 microconcentrators and directly injected into the capillary, while for urine specimens a simple water dilution before injection was needed. A baseline separation was obtained in less than 8 min using a 60.2 cm x 75 microm uncoated silica capillary, 75 mmol/L Tris-phosphate buffer pH 2.25 at 15 degrees C. The performance of the developed method was assessed by measuring plasma creatinine and Cn in 32 normal subjects and comparing the data obtained by the new method with those found with the previous CE assay. Our new method seems to be an inexpensive, fast and specific tool to assess a large number of patients both in clinical and in research laboratories.
Sample handling for mass spectrometric proteomic investigations of human urine.
Petri, Anette Lykke; Høgdall, Claus; Christensen, Ib Jarle; Simonsen, Anja Hviid; T'jampens, Davy; Hellmann, Marja-Leena; Kjaer, Susanne Krüger; Fung, Eric T; Høgdall, Estrid
2008-09-01
Because of its non-invasive sample collection method, human urine is an attractive biological material both for discovering biomarkers and for use in future screening trials for different diseases. Before urine can be used for these applications, standardized protocols for sample handling that optimize protein stability are required. In this explorative study, we examine the influence of different urine collection methods, storage temperatures, storage times, and repetitive freeze-thaw procedures on the protein profiles obtained by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS). Prospectively collected urine samples from 11 women were collected as either morning or midday specimens. The effects of storage temperature, time to freezing, and freeze-thaw cycles were assessed by calculating the number, intensity, and reproducibility of peaks visualized by SELDI-TOF-MS. On the CM10 array, 122 peaks were detected and 28 peaks were found to be significantly different between urine types, storage temperature and time to freezing. On the IMAC-Cu array, 65 peaks were detected and 1 peak was found to be significantly different according to time to freezing. No significant differences were demonstrated for freeze-thaw cycles. Optimal handling and storage conditions are necessary in clinical urine proteomic investigations. Collection of urine with a single and consistently performed protocol is needed to reduce analytical bias. Collecting only one urine type, which is stored for a limited period at 4°C until freezing at -80°C prior to analysis will provide the most stable profiles. Copyright © 2008 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Scott, Sasinya N; Ostrovnaya, Irina; Lin, Caroline M; Bouvier, Nancy; Bochner, Bernard H; Iyer, Gopakumar; Solit, David; Berger, Michael F; Lin, Oscar
2017-06-01
Biopsies from patients with high-risk (HR) non-muscle-invasive urothelial carcinoma (NMIUC), especially flat urothelial carcinoma in situ, frequently contain scant diagnostic material or denuded mucosa only, and this precludes further extensive genomic analysis. This study evaluated the use of next-generation sequencing (NGS) analysis of urine cytology material from patients with HR NMIUC in an attempt to identify genetic alterations that might correlate with clinical features and responses to bacille Calmette-Guérin (BCG) treatment. Forty-one cytology slides from patients with HR NMIUC treated with intravesical BCG were selected for this study. Histological confirmation was available for all cases. The specimens were subjected to NGS analysis with a customized targeted exome capture assay composed of 341 genes. In this cohort, genomic alterations were successfully identified in all cytology samples. Mutations were detected down to a 2% allele frequency and chromosomal rearrangements including copy number alterations and gene fusions were identified. The most frequently altered genes included telomerase reverse transcriptase (TERT), tumor protein 53 (TP53), Erb-B2 receptor tyrosine kinase 2 (ERBB2), and chromatin remodeling genes such as lysine demethylase 6A (KDM6A) and AT-rich interaction domain 1A (ARID1A). For patients with matched tumor tissue, cytology specimens revealed all mutations detected in tissue as well as additional mutations, and this suggested that urine might more effectively capture the full genetic heterogeneity of disease than an individual cystectomy. Alterations in multiple genes correlated with clinical and histopathological features, including responses to BCG treatment, flat architecture versus papillary architecture, and smoking history. Urine specimens can replace tissue as a substrate for NGS analysis of HR NMIUC. Several genomic alterations identified in urine specimens might be associated with histological features and clinical characteristics. Cancer Cytopathol 2017;125:416-26. © 2017 American Cancer Society. © 2017 American Cancer Society.
Cheng, Annie; Kirby, James E
2014-03-01
To evaluate the performance of the Hologic Gen-Probe (San Diego, CA) PANTHER system. The performance of PANTHER was compared with the Hologic Gen-Probe TIGRIS and/or Roche (Indianapolis, IN) COBAS AMPLICOR systems through testing of patient specimens and the spiked-urine matrix. After discrepant resolution, PANTHER demonstrated a 99.3% (95% confidence interval [CI], 96.0%-99.9%) positive and 100% (98.5%-100.0%) negative agreement for Chlamydia trachomatis (CT) and 100% (96.6%-100.0%) positive and 100% (98.6%-100.0%) negative agreement for Neisseria gonorrhoeae (NG) for all male, female, unsexed, and NG-spiked female urine specimens combined. For other specimen types collectively, the PANTHER demonstrated 100% (95% CI, 90.6%-100.0%) positive and 100% (88.3%-100.0%) negative agreement for CT and 90.9% (62.8%-98.4%) positive and 100% (93.5%-100.0%) negative agreement for NG. Analytical sensitivity of the PANTHER in urine matrix was similar to the TIGRIS system. The PANTHER system provides an excellent new addition to options for detecting CT and NG, is appropriate for testing urine samples, and will facilitate high-throughput testing in the clinical laboratory.
This procedure describes the process for collecting and analyzing blood and urine samples. The presence of chemical contaminants in biological specimens such as blood, urine, and hair represent a measure of the internal dose or body burden for a given individual derived from the ...
Schaefer, Nadine; Kettner, Mattias; Laschke, Matthias W; Schlote, Julia; Peters, Benjamin; Bregel, Dietmar; Menger, Michael D; Maurer, Hans H; Ewald, Andreas H; Schmidt, Peter H
2015-05-01
A series of new synthetic cannabinoids (SC) has been consumed without any toxicological testing. For example, pharmacokinetic data have to be collected from forensic toxicological case work and/or animal studies. To develop a corresponding model for assessing such data, samples of controlled pig studies with two selected SC (JWH-210, RCS-4) and, as reference, ∆(9)-tetrahydrocannabinol (THC) should be analyzed as well as those of human cases. Therefore, a method for determination of JWH-210, RCS-4, THC, and their main metabolites in pig and human serum, whole blood, and urine samples is presented. Specimens were analyzed by liquid-chromatography tandem mass spectrometry and multiple-reaction monitoring with three transitions per compound. Full validation was carried out for the pig specimens and cross-validation for the human specimens concerning precision and bias. For the pig studies, the limits of detection were between 0.05 and 0.50 ng/mL in serum and whole blood and between 0.05 and 1.0 ng/mL in urine, the lower limits of quantification between 0.25 and 1.0 ng/mL in serum and 0.50 and 2.0 ng/mL in whole blood and urine, and the intra- and interday precision values lower than 15% and bias values within ±15%. The applicability was tested with samples taken from a pharmacokinetic pilot study with pigs following intravenous administration of a mixture of 200 μg/kg body mass dose each of JWH-210, RCS-4, and THC. The cross-validation data for human serum, whole blood, and urine showed that this approach should also be suitable for human specimens, e.g., of clinical or forensic cases.
Reischies, Frederike M J; Raggam, Reinhard B; Prattes, Juergen; Krause, Robert; Eigl, Susanne; List, Agnes; Quehenberger, Franz; Strenger, Volker; Wölfler, Albert; Hoenigl, Martin
2016-03-01
Galactomannan (GM) testing of urine specimens may provide important advantages, compared to serum testing, such as easy noninvasive sample collection. We evaluated a total of 632 serial urine samples from 71 patients with underlying hematological malignancies and found that the urine GM/creatinine ratio, i.e., (urine GM level × 100)/urine creatinine level, which takes urine dilution into account, reliably detected invasive aspergillosis and may be a promising diagnostic tool for patients with hematological malignancies. (This study has been registered at ClinicalTrials.gov under registration no. NCT01576653.). Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Smith, Michael L; Nichols, Daniel C; Underwood, Paula; Fuller, Zachary; Moser, Matthew A; LoDico, Charles; Gorelick, David A; Newmeyer, Matthew N; Concheiro, Marta; Huestis, Marilyn A
2014-08-01
Opiates are an important component for drug testing due to their high abuse potential. Proper urine opiate interpretation includes ruling out poppy seed ingestion; however, detailed elimination studies after controlled poppy seed administration with known morphine and codeine doses are not available. Therefore, we investigated urine opiate pharmacokinetics after controlled oral administration of uncooked poppy seeds with known morphine and codeine content. Participants were administered two 45 g oral poppy seed doses 8 h apart, each containing 15.7 mg morphine and 3mg codeine. Urine was collected ad libitum up to 32 h after the first dose. Specimens were analyzed with the Roche Opiates II immunoassay at 2000 and 300 μg/L cutoffs, and the ThermoFisher CEDIA(®) heroin metabolite (6-acetylmorphine, 6-AM) and Lin-Zhi 6-AM immunoassays with 10 μg/L cutoffs to determine if poppy seed ingestion could produce positive results in these heroin marker assays. In addition, all specimens were quantified for morphine and codeine by GC/MS. Participants (N=22) provided 391 urine specimens over 32 h following dosing; 26.6% and 83.4% were positive for morphine at 2000 and 300 μg/L GC/MS cutoffs, respectively. For the 19 subjects who completed the study, morphine concentrations ranged from <300 to 7522 μg/L with a median peak concentration of 5239 μg/L. The median first morphine-positive urine sample at 2000 μg/L cutoff concentration occurred at 6.6 h (1.2-12.1), with the last positive from 2.6 to 18 h after the second dose. No specimens were positive for codeine at a cutoff concentration of 2000 μg/L, but 20.2% exceeded 300 μg/L, with peak concentrations of 658 μg/L (284-1540). The Roche Opiates II immunoassay had efficiencies greater than 96% for the 2000 and 300 μg/L cutoffs. The CEDIA 6-AM immunoassay had a specificity of 91%, while the Lin-Zhi assay had no false positive results. These data provide valuable information for interpreting urine opiate results. Copyright © 2014. Published by Elsevier Ireland Ltd.
Smith, Michael L.; Nichols, Daniel C.; Underwood, Paula; Fuller, Zachary; Moser, Matthew A.; LoDico, Charles; Gorelick, David A.; Newmeyer, Matthew N.; Concheiro, Marta; Huestis, Marilyn A.
2014-01-01
Opiates are an important component for drug testing due to their high abuse potential. Proper urine opiate interpretation includes ruling out poppy seed ingestion; however, detailed elimination studies after controlled poppy seed administration with known morphine and codeine doses are not available. Therefore, we investigated urine opiate pharmacokinetics after controlled oral administration of uncooked poppy seeds with known morphine and codeine content. Participants were administered two 45g oral poppy seed doses 8h apart, each containing 15.7mg morphine and 3mg codeine. Urine was collected ad libitum up to 32h after the first dose. Specimens were analyzed with the Roche Opiates II immunoassay at 2,000 and 300μg/L cutoffs, and the ThermoFisher CEDIA® Heroin Metabolite (6-acetylmorphine, 6AM) and Lin-Zhi 6AM immunoassays with 10μg/L cutoffs to determine if poppy seed ingestion could produce positive results in these heroin marker assays. In addition, all specimens were quantified for morphine and codeine by GC/MS. Participants (N=22) provided 391 urine specimens over 32h following dosing; 26.6% and 83.4% were positive for morphine at 2,000 and 300μg/L GC/MS cutoffs, respectively. For the 19 subjects who completed the study, morphine concentrations ranged from <300 to 7,522μg/L with a median peak concentration of 5,239μg/L. The median first morphine-positive urine sample at 2,000μg/L cutoff concentration occurred at 6.6h (1.2-12.1), with the last positive from 2.6 to 18h after the second dose. No specimens were positive for codeine at a cutoff concentration of 2,000μg/L, but 20.2% exceeded 300μg/L, with peak concentrations of 658 μg/L (284-1540). The Roche Opiates II immunoassay had efficiencies greater than 96% for the 2000 and 300μg/L cutoffs. The CEDIA 6AM immunoassay had a specificity of 91%, while the Lin-Zhi assay had no false positive results. These data provide valuable information for interpreting urine opiate results. PMID:24887324
Alvarado-Esquivel, Cosme; García-Corral, Nora; Carrero-Dominguez, David; Enciso-Moreno, José Antonio; Gurrola-Morales, Teodoro; Portillo-Gómez, Leopoldo; Rossau, Rudi; Mijs, Wouter
2009-01-01
Background Little information is available on the molecular epidemiology in Mexico of Mycobacterium species infecting extrapulmonary sites in humans. This study used molecular methods to determine the Mycobacterium species present in tissues and body fluids in specimens obtained from patients in Mexico with extrapulmonary disease. Methods Bacterial or tissue specimens from patients with clinical or histological diagnosis of extrapulmonary tuberculosis were studied. DNA extracts from 30 bacterial cultures grown in Löwenstein Jensen medium and 42 paraffin-embedded tissues were prepared. Bacteria were cultured from urine, cerebrospinal fluid, pericardial fluid, gastric aspirate, or synovial fluid samples. Tissues samples were from lymph nodes, skin, brain, vagina, and peritoneum. The DNA extracts were analyzed by PCR and by line probe assay (INNO-LiPA MYCOBACTERIA v2. Innogenetics NV, Gent, Belgium) in order to identify the Mycobacterium species present. DNA samples positive for M. tuberculosis complex were further analyzed by PCR and line probe assay (INNO-LiPA Rif.TB, Innogenetics NV, Gent, Belgium) to detect mutations in the rpoB gene associated with rifampicin resistance. Results Of the 72 DNA extracts, 26 (36.1%) and 23 (31.9%) tested positive for Mycobacterium species by PCR or line probe assay, respectively. In tissues, M. tuberculosis complex and M. genus were found in lymph nodes, and M. genus was found in brain and vagina specimens. In body fluids, M. tuberculosis complex was found in synovial fluid. M. gordonae, M. smegmatis, M. kansasii, M. genus, M. fortuitum/M. peregrinum complex and M. tuberculosis complex were found in urine. M. chelonae/M. abscessus was found in pericardial fluid and M. kansasii was found in gastric aspirate. Two of M. tuberculosis complex isolates were also PCR and LiPA positive for the rpoB gene. These two isolates were from lymph nodes and were sensitive to rifampicin. Conclusion 1) We describe the Mycobacterium species diversity in specimens derived from extrapulmonary sites in symptomatic patients in Mexico; 2) Nontuberculous mycobacteria were found in a considerable number of patients; 3) Genotypic rifampicin resistance in M. tuberculosis complex infections in lymph nodes was not found. PMID:19272158
Urine analysis concerning xenon for doping control purposes.
Thevis, Mario; Piper, Thomas; Geyer, Hans; Schaefer, Maximilian S; Schneemann, Julia; Kienbaum, Peter; Schänzer, Wilhelm
2015-01-15
On September 1(st) 2014, a modified Prohibited List as established by the World Anti-Doping Agency (WADA) became effective featuring xenon as a banned substance categorized as hypoxia-inducible factor (HIF) activator. Consequently, the analysis of xenon from commonly provided doping control specimens such as blood and urine is desirable, and first data on the determination of xenon from urine in the context of human sports drug testing, are presented. In accordance to earlier studies utilizing plasma as doping control matrix, urine was enriched to saturation with xenon, sequentially diluted, and the target analyte was detected as supported by the internal standard d6 -cyclohexanone by means of gas chromatography/triple quadrupole mass spectrometry (GC/MS/MS) using headspace injection. Three major xenon isotopes at m/z 128.9, 130.9 and 131.9 were targeted in (pseudo) selected reaction monitoring mode enabling the unambiguous identification of the prohibited substance. Assay characteristics including limit of detection (LOD), intraday/interday precision, and specificity as well as analyte recovery under different storage conditions were determined. Proof-of-concept data were generated by applying the established method to urine samples collected from five patients before, during and after (up to 48 h) xenon-based general anesthesia. Xenon was traceable in enriched human urine samples down to the detection limit of approximately 0.5 nmol/mL. The intraday and interday imprecision values of the method were found below 25%, and specificity was demonstrated by analyzing 20 different blank urine samples that corroborated the fitness-for-purpose of the analytical approach to unequivocally detect xenon at non-physiological concentrations in human urine. The patients' urine specimens returned 'xenon-positive' test results up to 40 h post-anesthesia, indicating the limits of the expected doping control detection window. Since xenon has been considered a prohibited substance according to WADA regulations in September 2014, its analysis from common specimens of routine sports drug testing is desirable. In previous studies, its traceability in whole blood and plasma was shown, and herein a complementary approach utilizing doping control urine samples for the GC/MS/MS analysis of xenon was reported. Copyright © 2014 John Wiley & Sons, Ltd.
Ellefsen, Kayla N.; Anizan, Sébastien; Castaneto, Marisol S.; Desrosiers, Nathalie A.; Martin, LTC Thomas M.; Klette, CAPT Kevin L.; Huestis, Marilyn A.
2014-01-01
Deterrence of synthetic cathinone abuse is hampered by the lack of a high-throughput immunoassay screen. The Randox Drugs of Abuse V biochip immunoassay (DOA-V) contains two synthetic cathinones antibodies: Bath Salt I (BSI) targets mephedrone/methcathinone and Bath Salt II (BSII) targets 3’,4’-methylenedioxypyrovalerone (MDPV)/3’,4’-methylenedioxy-α-pyrrolidinobutiophenone (MDPBP). We evaluated DOA-V synthetic cathinones performance and conducted a full validation on the original assay with calibrators reconstituted in water, and the new assay with calibrators prepared in lyophilized urine; both utilized the same antibodies and were run on the fully automated Evidence® Analyzer. 20,017 authentic military urine specimens were screened and confirmed by LC-MS/MS for 28 synthetic cathinones. Limits of detection (LOD) for the original and new assays were 0.35 and 0.18 (BSI), and 8.5 and 9.2µg/L (BSII), respectively. Linearity was acceptable (R2>0.98); however, a large negative bias was observed with in-house prepared calibrators. Intra-assay imprecision was <20% BSI-II, while inter-assay imprecision was 18–42% BSI and <22% BSII. Precision was acceptable for Randox controls. Cross-reactivities of many additional synthetic cathinones were determined. Authentic drug-free negative urine pH <4 produced false positive results for BSI (6.3µg/L) and BSII (473µg/L). Oxidizing agents reduced BSI and increased BSII results. Sensitivity, specificity, and efficiency of 100%, 52.1%, and 53.0% were obtained at manufacturer’s proposed cutoffs (BSI 5µg/L, BSII 30µg/L). Performance improved if cutoff concentrations increased (BSI 7.5µg/L, BSII 40µg/L); however, there were limited confirmed positive specimens. Currently, this is the first and only fully validated immunoassay for preliminary detection of synthetic cathinones in urine. PMID:24659527
Shakleya, Diaa M.; Dams, Riet; Choo, Robin E.; Jones, Hendree; Huestis, Marilyn A.
2011-01-01
Opiates, cocaine, and metabolites were quantified by liquid chromatography–mass spectrometry (LC–MS) in 284 urine specimens, collected thrice weekly, to monitor possible drug relapse in 15 pregnant heroin-dependent women. Opiates were detected in 149 urine specimens (52%) with limits of quantification (LOQ) of 10–50 μg/L. Morphine, morphine-3-glucuronide, and/or morphine-6-glucuronide were positive in 121 specimens; 6-acetylmorphine, a biomarker of heroin ingestion, was quantifiable in only 7. No heroin, 6-acetylcodeine, papaverine, or noscapine were detected. One hundred and sixty-five urine specimens (58%) from all 15 participants were positive for one or more cocaine analytes (LOQ 10–100 μg/L). Ecgonine methylester (EME) and/or benzoylecgonine were the major cocaine biomarkers in 142. Anhydroecgonine methylester, a biomarker of smoked cocaine, was positive in six; cocaethylene and/or ecgonine ethylester, biomarkers of cocaine and ethanol co-ingestion, were found in 25. At the current Substance Abuse Mental Health Services Administration cutoffs for total morphine (2000 μg/L), codeine (2000 μg/L), 6-acetylmorphine (10 μg/L), and benzoylecgonine (100 μg/L), 16 opiate- and 29 cocaine-positive specimens were identified. Considering 100 μg/L EME as an additional urinary cocaine biomarker would identify 51 more positive cocaine specimens. Of interest is the differential pattern of opiate and cocaine biomarkers observed after LC–MS as compared to gas chromatography–mass spectrometry analysis. PMID:20109298
Urinalysis: case presentations for the primary care physician.
Sharp, Victoria J; Lee, Daniel K; Askeland, Eric J
2014-10-15
Urinalysis is useful in diagnosing systemic and genitourinary conditions. In patients with suspected microscopic hematuria, urine dipstick testing may suggest the presence of blood, but results should be confirmed with a microscopic examination. In the absence of obvious causes, the evaluation of microscopic hematuria should include renal function testing, urinary tract imaging, and cystoscopy. In a patient with a ureteral stent, urinalysis alone cannot establish the diagnosis of urinary tract infection. Plain radiography of the kidneys, ureters, and bladder can identify a stent and is preferred over computed tomography. Asymptomatic bacteriuria is the isolation of bacteria in an appropriately collected urine specimen obtained from a person without symptoms of a urinary tract infection. Treatment of asymptomatic bacteriuria is not recommended in nonpregnant adults, including those with prolonged urinary catheter use.
Clinical evaluation and use of urine screening for drug abuse.
Saxon, A J; Calsyn, D A; Haver, V M; Delaney, C J
1988-01-01
Urine drug screening is indicated to evaluate patients who show mental status or behavioral changes and to monitor the abstinence of drug abusers. The appropriate timing for collecting urine specimens may vary depending on the suspected drug of abuse and on laboratory factors. Laboratories use a variety of techniques to do urine screens, and these must be understood by clinicians ordering the screens to interpret results correctly. In treating drug-abusing patients, clinicians must apply structured reinforcement in conjunction with urine screen results to aid patients in achieving abstinence. PMID:3176489
Stability of Synthetic Cathinones in Urine.
Glicksberg, Lindsay; Kerrigan, Sarah
2018-03-01
In this report, we evaluate the concentration, pH, temperature and analyte-dependent effects on cathinone stability in preserved human urine. A total of 22 synthetic cathinones were evaluated at 100 ng/mL and 1,000 ng/mL in pH 4 and pH 8 urine over 6 months. Specimens were stored at -20°C, 4°C, 20°C and 32°C. The stability of synthetic cathinones was highly dependent on urine pH and storage temperature. Cathinones were considerably more stable in acidic urine (pH 4) at low temperature. In alkaline urine (pH 8) at 32°C, significant losses (>20%) were observed within hours for the majority of drugs. In contrast, all drugs were stable in frozen and refrigerated urine at pH 4 for the duration of the study. These results highlight the importance of sample storage and the potential for pre-analytical changes in concentration during routine shipping and handling of specimens. Significant structural influence was also observed. Cathinones bearing a tertiary amine (pyrrolidine group) were significantly more stable than their secondary amine counterparts. The methylenedioxy group also exerted a significant stabilizing effect on both the tertiary and secondary amines. In the absence of the methylenedioxy group, no significant differences in stability were observed between the unsubstituted and ring substituted secondary amines. Half-lives at ambient temperature in pH 8 urine ranged from 9 h (3-fluoromethcathinone) to 4.3 months (methylenedioxypyrovalerone and 3,4-methylenedioxy-α-pyrrolidinobutiophenone), demonstrating the importance of analyte dependence, and the dual stabilizing effect of both the pyrollidine and methylenedioxy groups. Biological evidence may be subjected to a variety of environmental conditions prior to, and during transport to the forensic laboratory. These findings demonstrate the inherent instability of certain cathinone species in biological evidence under some conditions. Moreover, this study highlights the need for quantitative drug findings in toxicological investigations to be interpreted cautiously, and within the context of specimen storage and integrity.
49 CFR 40.41 - Where does a urine collection for a DOT drug test take place?
Code of Federal Regulations, 2010 CFR
2010-10-01
... shipping of urine specimens to a laboratory, and a suitable clean surface for writing. (d) Your collection... section. (e) The first, and preferred, type of facility for urination that a collection site may include... event of a directly observed collection. (2) You must have a source of water for washing hands, that, if...
Urine Creatinine Concentrations in Drug Monitoring Participants and Hospitalized Patients.
Love, Sara A; Seegmiller, Jesse C; Kloss, Julie; Apple, Fred S
2016-10-01
Urine drug testing is commonly performed in both clinical and forensic arenas for screening, monitoring and compliance purposes. We sought to determine if urine creatinine concentrations in monitoring program participants were significantly different from hospital in-patients and out-patients undergoing urine drug testing. We retrospectively reviewed urine creatinine submitted in June through December 2015 for all specimens undergoing urine drug testing. The 20,479 creatinine results were categorized as hospitalized patients (H) and monitoring/compliance groups for pain management (P), legal (L) or recovery (R). Median creatinine concentrations (interquartile range, mg/dL) were significantly different (P < 0.001) between groups: H 126 (122-136); P 138 (137-143); L 147 (144-154); R 95 (92-97). In the two groups subject to on-demand sampling time pressures, median creatinine concentrations were significantly lower in the R vs. L group (P<0.001). In conclusion, recovery (R) participants have more dilute specimens, reflected by significantly lower creatinine concentration and may indicate participants' attempts to tamper with their drug test results through dilution means. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Peter, Harald; Berggrav, Kathrine; Thomas, Peter; Pfeifer, Yvonne; Witte, Wolfgang; Templeton, Kate
2012-01-01
Klebsiella pneumoniae carbapenemases (KPCs) are considered a serious threat to antibiotic therapy, as they confer resistance to carbapenems, which are used to treat extended-spectrum beta-lactamase (ESBL)-producing bacteria. Here, we describe the development and evaluation of a DNA microarray for the detection and genotyping of KPC genes (blaKPC) within a 5-h period. To test the whole assay procedure (DNA extraction plus a DNA microarray assay) directly from clinical specimens, we compared two commercial DNA extraction kits (the QIAprep Spin miniprep kit [Qiagen] and the urine bacterial DNA isolation kit [Norgen]) for the direct DNA extraction from urine samples (dilution series spiked in human urine). Reliable single nucleotide polymorphism (SNP) typing was demonstrated using 1 × 105 CFU/ml urine for Escherichia coli (Qiagen and Norgen) and 80 CFU/ml urine, on average, for K. pneumoniae (Norgen). This study presents, for the first time, the combination of a new KPC microarray with commercial sample preparation for detecting and genotyping microbial pathogens directly from clinical specimens; this paves the way toward tests providing epidemiological and diagnostic data, enabling better antimicrobial stewardship. PMID:23035190
Moreno, Ivo; Barroso, Mário; Martinho, Ana; Cruz, Angelines; Gallardo, Eugenia
2015-11-01
Ketamine is a club drug widely abused for its hallucinogenic effects, being also used as a "date-rape" drug in recent years. We have developed an analytical method using gas chromatography-tandem mass spectrometry (GC-MS/MS) for the identification and quantification of ketamine and its major metabolite in urine and plasma. No derivatization step is needed to accomplish analysis. The compounds were extracted from 0.25mL of sample using microextraction by packed sorbent on mixed mode (M1) cartridges. Calibration curves were linear in the range of 10-250ng/mL for urine and 10-500ng/mL for plasma, with determination coefficients higher than 0.99. The limit of detection (LOD) was 5ng/mL for both compounds in both specimens. Recoveries ranged from 63 to 101%, while precision and accuracy were below 14% and 15%, respectively. These low limits of detection and the quite high recoveries obtained, in very low sample amounts, allow detecting small quantities of the compounds, making this procedure suitable for those laboratories performing routine analysis in the field of forensic toxicology. Compared with existing methods, the herein described procedure is fast, since no derivatization step is required, and cost effective for the quantification of ketamine and norketamine in biological specimens by gas chromatography. Copyright © 2015 Elsevier B.V. All rights reserved.
Kocer, Derya; Sarıguzel, Fatma M; Karakukcu, Cıgdem
2014-08-01
The microscopic analysis of urine is essential for the diagnosis of patients with urinary tract infections. Quantitative urine culture is the 'gold standard' method for definitive diagnosis of urinary-tract infections, but it is labor-intensive, time consuming, and does not provide the same-day results. The aim of this study was to evaluate the analytical and diagnostic performance of the FUS200 (Changchun Dirui Industry, China), a new urine sedimentation analyzer in comparison to urine culture as the reference method. We evaluated 1000 urine samples, submitted for culture and urine analysis with a preliminary diagnosis of urinary-tract infection. Cut-off values for the FUS200 were determined by comparing the results with urine cultures. The cut-off values by the receiver operating characteristic (ROC) curve technique, sensitivity, and specificity were calculated for bacteria and white blood cells (WBCs). Among the 1000 urine specimens submitted for culture, 637 cultures (63.7%) were negative, and 363 were (36.3%) positive. The best cut-off values obtained from ROC analysis were 16/μL for bacteriuria (sensitivity: 82.3%, specificity: 58%), and 34/μL for WBCs (sensitivity: 72.3%, specificity: 65.2%). The area under the curve (AUC) for the bacteria and WBCs count were 0.71 (95% CI: 0.67-0.74) and, 0.72 (95% CI: 0.69-0.76) respectively. The most important requirement of a rapid diagnostic screening test is sensitivity, and, in this perspective, an unsatisfactory sensitivity by using bacteria recognition and quantification performed by the FUS200 analyzer has been observed. After further technical improvements in particle recognition and laboratory personnel training, the FUS200 might show better results.
Utility of the Paris System in Reporting Urine Cytology.
Malviya, Kiran; Fernandes, Gwendolyn; Naik, Leena; Kothari, Kanchan; Agnihotri, Mona
2017-01-01
To find out the utility of The Paris System (TPS) in reporting urine cytology and to compare it with the reporting system currently used in our laboratory. This retrospective study was undertaken over a period of 1 year during which slides of all the urine specimens sent for cytological examination were retrieved from our laboratory filling system. They were blindly reviewed and reclassified according to TPS. Surgical follow-up was obtained from the uropathology services of our department. A total of 176 cases were meticulously reviewed. The mean age of the patients was 52 years, and 71% of cases presented with hematuria. Histopathological follow-up was available in 34 cases. Reporting by TPS detected 13.0% high-grade urothelial carcinoma (HGUC) and 5.1% atypical urothelial cells versus 7.3 and 11.9% by the current reporting system, respectively. The sensitivity and diagnostic accuracy for detecting HGUC of TPS were higher than those of our reporting system. TPS has increased the rate of detection of HGUC and reduced the rate of reporting "atypical" urothelial cells. TPS has also standardized the diagnostic criteria, thereby bringing uniformity and reproducibility into the system of reporting for urine cytology. © 2017 S. Karger AG, Basel.
Normalization of urinary drug concentrations with specific gravity and creatinine.
Cone, Edward J; Caplan, Yale H; Moser, Frank; Robert, Tim; Shelby, Melinda K; Black, David L
2009-01-01
Excessive fluid intake can substantially dilute urinary drug concentrations and result in false-negative reports for drug users. Methods for correction ("normalization") of drug/metabolite concentrations in urine have been utilized by anti-doping laboratories, pain monitoring programs, and in environmental monitoring programs to compensate for excessive hydration, but such procedures have not been used routinely in workplace, legal, and treatment settings. We evaluated two drug normalization procedures based on specific gravity and creatinine. These corrections were applied to urine specimens collected from three distinct groups (pain patients, heroin users, and marijuana/ cocaine users). Each group was unique in characteristics, study design, and dosing conditions. The results of the two normalization procedures were highly correlated (r=0.94; range, 0.78-0.99). Increases in percent positives by specific gravity and creatinine normalization were small (0.3% and -1.0%, respectively) for heroin users (normally hydrated subjects), modest (4.2-9.8%) for pain patients (unknown hydration state), and substantial (2- to 38-fold increases) for marijuana/cocaine users (excessively hydrated subjects). Despite some limitations, these normalization procedures provide alternative means of dealing with highly dilute, dilute, and concentrated urine specimens. Drug/metabolite concentration normalization by these procedures is recommended for urine testing programs, especially as a means of coping with dilute specimens.
STS-40 Exp. No. 192 urine monitoring system (UMS) on OV-102's middeck
NASA Technical Reports Server (NTRS)
1991-01-01
STS-40 Experiment No. 192, Fluid-Electrolyte Regulation During Space Flight, urine monitoring system (UMS) is set up on the middeck of Columbia, Orbiter Vehicle (OV) 102, at the side hatch. The UMS is attached to OV-102's waste collection system (WCS). The urine specimen tray with sample tubes appears to the right of the UMS equipment.
10 CFR 26.85 - Collector qualifications and responsibilities.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Collector qualifications and responsibilities. 26.85 Section 26.85 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.85 Collector qualifications and responsibilities. (a) Urine collector qualifications. Urine...
10 CFR 26.85 - Collector qualifications and responsibilities.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Collector qualifications and responsibilities. 26.85 Section 26.85 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.85 Collector qualifications and responsibilities. (a) Urine collector qualifications. Urine...
10 CFR 26.85 - Collector qualifications and responsibilities.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Collector qualifications and responsibilities. 26.85 Section 26.85 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.85 Collector qualifications and responsibilities. (a) Urine collector qualifications. Urine...
10 CFR 26.85 - Collector qualifications and responsibilities.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Collector qualifications and responsibilities. 26.85 Section 26.85 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.85 Collector qualifications and responsibilities. (a) Urine collector qualifications. Urine...
10 CFR 26.85 - Collector qualifications and responsibilities.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Collector qualifications and responsibilities. 26.85 Section 26.85 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.85 Collector qualifications and responsibilities. (a) Urine collector qualifications. Urine...
The use of a differential fluorescent staining method to detect bacteriuria.
Ciancaglini, Ettore; Fazii, Paolo; Sforza, Giuseppe Riario
2004-01-01
This report describes a differential staining method which distinguishes gram-positive from gram-negative bacteria in fluorescence. Gram-positive bacteria appear yellow and gram-negative bacteria appear green. The method is based on two fluorochromes, one acting in the wavelength of red, i.e. the acridine orange, and another acting in the wavelength of green, i.e. the fluorescein, which together form a red/ green system. In this report we compared the accuracy of the differential fluorescent staining method and the Gram stain in screening for bacteriuria, as detected by conventional cultures. A total of 1487 urine samples were tested. 289 cultures were positive. 237 specimens grew a single organism at 10(5) and 10(4) CFU/ml. 224 smears were detected by the differential fluorescent staining method and 162 were detected by Gram stain. 1198 samples failed to grow organisms at 10(5) and 10(4) CFU/ml. 107 smears were falsely positive by the fluorescent staining procedure and 289 were falsely positive by the Gram stain. On the basis of the culture results, the sensitivity of the differential fluorescent staining method was 94.5% and that of the Gram stain 68.3%. The specificity of the fluorescent staining procedure was 91.6% and that of the Gram stain 75.8%. The positive predictive value and the negative predictive value of the fluorescent staining method were 67.6% and 98.8%, respectively. Those of the Gram stain were 35.9% and 92.3%, respectively. A wide range of microbiological and chemical techniques are available to identify bacteria in urine. This fluorescent staining method represents a simple, rapid, reliable method with low-running costs. The main advantage of this technique is that it enables the microbiologist to exclude the presence of bacteria in the urine within a short time after specimen receipt and to eliminate a large number of specimens for culture with significant cost saving. Another advantage of the method is that it allows to distinguish gram-positive from gram-negative bacteria in positive slides on the same day the sample is obtained. The stained smears were easily interpreted, even when the bacterial counts in the specimen were low.
Huijts, Susanne M.; Wu, Kangjian; Souza, Victor; Passador, Sherry; Tinder, Chunyan; Song, Esther; Elfassy, Arik; McNeil, Lisa; Menton, Ronald; French, Roger; Callahan, Janice; Webber, Chris; Gruber, William C.; Bonten, Marc J. M.; Jansen, Kathrin U.
2012-01-01
To improve the clinical diagnosis of pneumococcal infection in bacteremic and nonbacteremic community-acquired pneumonia (CAP), a Luminex technology-based multiplex urinary antigen detection (UAD) diagnostic assay was developed and validated. The UAD assay can simultaneously detect 13 different serotypes of Streptococcus pneumoniae by capturing serotype-specific S. pneumoniae polysaccharides (PnPSs) secreted in human urine. Assay specificity is achieved by capturing the polysaccharides with serotype-specific monoclonal antibodies (MAbs) on spectrally unique microspheres. Positivity for each serotype was based on positivity cutoff values calculated from a standard curve run on each assay plate together with positive- and negative-control urine samples. The assay is highly specific, since significant signals are detected only when each PnPS was paired with its homologous MAb-coated microspheres. Validation experiments demonstrated excellent accuracy and precision. The UAD assay and corresponding positivity cutoff values were clinically validated by assessing 776 urine specimens obtained from patients with X-ray-confirmed CAP. The UAD assay demonstrated 97% sensitivity and 100% specificity using samples obtained from patients with bacteremic, blood culture-positive CAP. Importantly, the UAD assay identified Streptococcus pneumoniae (13 serotypes) in a proportion of individuals with nonbacteremic CAP, a patient population for which the pneumococcal etiology of CAP was previously difficult to assess. Therefore, the UAD assay provides a specific, noninvasive, sensitive, and reproducible tool to support vaccine efficacy as well as epidemiological evaluation of pneumococcal disease, including CAP, in adults. PMID:22675155
Pride, Michael W; Huijts, Susanne M; Wu, Kangjian; Souza, Victor; Passador, Sherry; Tinder, Chunyan; Song, Esther; Elfassy, Arik; McNeil, Lisa; Menton, Ronald; French, Roger; Callahan, Janice; Webber, Chris; Gruber, William C; Bonten, Marc J M; Jansen, Kathrin U
2012-08-01
To improve the clinical diagnosis of pneumococcal infection in bacteremic and nonbacteremic community-acquired pneumonia (CAP), a Luminex technology-based multiplex urinary antigen detection (UAD) diagnostic assay was developed and validated. The UAD assay can simultaneously detect 13 different serotypes of Streptococcus pneumoniae by capturing serotype-specific S. pneumoniae polysaccharides (PnPSs) secreted in human urine. Assay specificity is achieved by capturing the polysaccharides with serotype-specific monoclonal antibodies (MAbs) on spectrally unique microspheres. Positivity for each serotype was based on positivity cutoff values calculated from a standard curve run on each assay plate together with positive- and negative-control urine samples. The assay is highly specific, since significant signals are detected only when each PnPS was paired with its homologous MAb-coated microspheres. Validation experiments demonstrated excellent accuracy and precision. The UAD assay and corresponding positivity cutoff values were clinically validated by assessing 776 urine specimens obtained from patients with X-ray-confirmed CAP. The UAD assay demonstrated 97% sensitivity and 100% specificity using samples obtained from patients with bacteremic, blood culture-positive CAP. Importantly, the UAD assay identified Streptococcus pneumoniae (13 serotypes) in a proportion of individuals with nonbacteremic CAP, a patient population for which the pneumococcal etiology of CAP was previously difficult to assess. Therefore, the UAD assay provides a specific, noninvasive, sensitive, and reproducible tool to support vaccine efficacy as well as epidemiological evaluation of pneumococcal disease, including CAP, in adults.
Poch, G K; Klette, K L; Hallare, D A; Manglicmot, M G; Czarny, R J; McWhorter, L K; Anderson, C J
1999-03-05
Seventy-four urine specimens previously found to contain lysergic acid diethylamide (LSD) by gas chromatography-mass spectrometry (GC-MS) were analyzed by a new procedure for the LSD metabolite 2-oxo-3-hydroxy-LSD (O-H-LSD) using a Finnigan LC-MS-MS system. This procedure proved to be less complex, shorter to perform and provides cleaner chromatographic characteristics than the method currently utilized by the Navy Drug Screening Laboratories for the extraction of LSD from urine by GC-MS. All of the specimens used in the study screened positive for LSD by radioimmunoassay (Roche Abuscreen). Analysis by GC-MS revealed detectable amounts of LSD in all of the specimens. In addition, isolysergic diethylamide (iso-LSD), a byproduct of LSD synthesis, was quantitated in 64 of the specimens. Utilizing the new LC-MS-MS method, low levels of N-desmethyl-LSD (nor-LSD), another identified LSD metabolite, were detected in some of the specimens. However, all 74 specimens contained O-H-LSD at significantly higher concentrations than LSD, iso-LSD, or nor-LSD alone. The O-H-LSD concentration ranged from 732 to 112 831 pg/ml (mean, 16340 pg/ml) by quantification with an internal standard. The ratio of O-H-LSD to LSD ranged from 1.1 to 778.1 (mean, 42.9). The presence of O-H-LSD at substantially higher concentrations than LSD suggests that the analysis for O-H-LSD as the target analyte by employing LC-MS-MS will provide a much longer window of detection for the use of LSD than the analysis of the parent compound, LSD.
Rossini, Giada; Gaibani, Paolo; Vocale, Caterina; Cagarelli, Roberto; Landini, Maria Paola
2017-09-01
The capability to detect ZIKV RNA is of crucial importance for cases confirmation. However, due to the short-lived viremia, the detection of ZIKV RNA in plasma/serum is challenging for samples collected more than one week after onset of clinical illness. We compared the window time and detection rate of ZIKV RNA in different specimen types (plasma, whole blood and urine) collected simultaneously at several times post-symptom onset. We examined the presence of ZIKV RNA in matched specimens of whole blood, plasma and urine collected in the same date (3-28 days after symptom onset) from 10 ZIKV infected patients. ZIKV RNA was found in plasma as late as 10 days after symptoms onset and tested positive in all 5 (100%) and in 2 of 6 (33,3%) plasma samples collected 1-5 and 6-10 days after symptoms onset, respectively. ZIKV RNA was positive in urine through the 21st day after symptom onset; the detection rate of ZIKV RNA in urine samples was 100% (11/11) for samples collected 1-10 days from symptoms onset, decreasing at later times of sampling. The detection rate of ZIKV RNA in whole blood was comparable to that in urine samples but extended the window of detection of ZIKV RNA up to 26 days after symptom onset. Our results highlight the usefulness of simultaneously testing multiple specimen types in order to extend the rate and the time frame of ZIKV RNA detection, increasing the possibility of cases confirmation through direct diagnosis in convalescence-phase of infection, supplementing serological data which are often difficult to interpret. Copyright © 2017 The British Infection Association. Published by Elsevier Ltd. All rights reserved.
Monitoring cocaine use in substance-abuse-treatment patients by sweat and urine testing.
Preston, K L; Huestis, M A; Wong, C J; Umbricht, A; Goldberger, B A; Cone, E J
1999-09-01
Sweat and urine specimens were collected from 44 methadone-maintenance patients to evaluate the use of sweat testing to monitor cocaine use. Paired sweat patches that were applied and removed weekly (on Tuesdays) were compared with 3-5 consecutive urine specimens collected Mondays, Wednesdays, and Fridays. All patches (N = 930) were extracted in 2.5 mL of solvent and analyzed by ELISA immunoassay (cutoff concentration 10 ng/mL); a subset of patches (N = 591) was also analyzed by gas chromatography-mass spectrometry (GC-MS) for cocaine, benzoylecgonine (BZE), and ecgonine methyl ester (EME) (cutoff concentration 5 ng/mL). Urine specimens were subjected to qualitative analysis by EMIT (cutoff 300 ng/mL) and subsets were analyzed by TDx (semiquantitative, LOD 30 ng/mL) and by GC-MS for cocaine (LOD 5 ng/mL). Results were evaluated to (1) determine the relative amounts of cocaine and its metabolites in sweat; (2) assess replicability in duplicate patches; (3) compare ELISA and GC-MS results for cocaine in sweat; and (4) compare the detection of cocaine use by sweat and urine testing. Cocaine was detected by GC-MS in 99% of ELISA-positive sweat patches; median concentrations of cocaine, BZE, and EME were 378, 78.7, and 74 ng/mL, respectively. Agreement in duplicate patches was approximately 90% by ELISA analysis. The sensitivity, specificity, and efficiency of sweat ELISA cocaine results as compared with sweat GC-MS results were 93.6%, 91.3%, and 93.2%, respectively. The sensitivity, specificity, and efficiency between ELISA sweat patch and EMIT urine results were 97.6%, 60.5%, and 77.7%, respectively. These results support the use of sweat patches for monitoring cocaine use, though further evaluation is needed.
Alpha-fetoprotein as a tool to distinguish amniotic fluid from urine, vaginal discharge, and semen.
Mor, Amir; Tal, Reshef; Haberman, Shoshana; McCalla, Sandra; Irani, Mohamad; Perlman, Jaqueline; Seifer, David B; Minkoff, Howard
2015-02-01
To estimate whether alpha-fetoprotein (AFP) can be used to distinguish amniotic fluid absorbed in sanitary pads from other similarly absorbed substances (semen, urine, and normal vaginal discharge). A prospective cohort study. Urine and amniotic fluid specimens were collected from 52 pregnant women admitted for labor. Semen specimens were collected from 17 men undergoing infertility evaluation. Alpha-fetoprotein concentrations were measured directly from urine, amniotic fluid, and semen and from pads instilled with samples from these specimens. Alpha-fetoprotein concentrations were also measured from pads absorbed with normal vaginal discharge collected from 27 pregnant women. Alpha-fetoprotein levels in amniotic fluid (245.38 ± 21.03 ng/mL, n = 52) were significantly higher than those measured in maternal urine (0.84 ± 0.17 ng/mL, n = 52, P < .001), or semen (1.52 ± 0.35 ng/mL, n = 17, P < .001). The same trend was seen when AFP was extracted from pads: amniotic fluid levels (19.44 ± 1.98 ng/mL, n=52) were significantly higher than those of urine (undetectable, n=52), semen (undetectable, n = 17), or normal vaginal discharge (0.53 ± 0.16 ng/mL, n = 27, P < .001). Receiver operator characteristic curve analysis demonstrated 96.2% sensitivity and 100% specificity for distinguishing the presence of amniotic fluid from normal vaginal discharge on sanitary pads (cutoff 3.88 ng/mL, area under the curve 0.99). When the diagnosis of rupture of membranes is in doubt, AFP levels can assist in differentiating amniotic fluid from other bodily fluids. A method that utilizes sanitary pads and an assay for AFP quantification may be an accurate and convenient way to confirm the diagnosis of rupture of membranes.
Lawn, Stephen D; Kerkhoff, Andrew D; Burton, Rosie; Schutz, Charlotte; Boulle, Andrew; Vogt, Monica; Gupta-Wright, Ankur; Nicol, Mark P; Meintjes, Graeme
2017-03-21
We previously reported that one-third of HIV-positive adults requiring medical admission to a South African district hospital had laboratory-confirmed tuberculosis (TB) and that almost two-thirds of cases could be rapidly diagnosed using Xpert MTB/RIF-testing of concentrated urine samples obtained on the first day of admission. Implementation of urine-based, routine, point-of-care TB screening is an attractive intervention that might be facilitated by use of a simple, low-cost diagnostic tool, such as the Determine TB-LAM lateral-flow rapid test for HIV-associated TB. Sputum, urine and blood samples were systematically obtained from unselected HIV-positive adults within 24 hours of admission to a South African township hospital. Additional clinical samples were obtained during hospitalization as clinically indicated. TB was defined by the detection of Mycobacterium tuberculosis in any sample using Xpert MTB/RIF or liquid culture. The diagnostic yield, accuracy and prognostic value of urine-lipoarabinomannan (LAM) testing were determined, but urine-LAM results did not inform treatment decisions. Consecutive HIV-positive adult acute medical admissions not already receiving TB treatment (n = 427) were enrolled regardless of clinical presentation or symptoms. TB was diagnosed in 139 patients (TB prevalence 32.6%; median CD4 count 80 cells/μL). In the first 24 hours of admission, sputum (spot and/or induced) samples were obtained from 37.0% of patients and urine samples from 99.5% of patients (P < 0.001). The diagnostic yields from these specimens were 19.4% (n = 27/139) for sputum-microscopy, 26.6% (n = 37/139) for sputum-Xpert, 38.1% (n = 53/139) for urine-LAM and 52.5% (n = 73/139) for sputum-Xpert/urine-LAM combined (P < 0.01). Corresponding yields among patients with CD4 counts <100 cells/μL were 18.9%, 24.3%, 55.4% and 63.5%, respectively (P < 0.01). The diagnostic yield of urine-LAM was unrelated to respiratory symptoms, and LAM assay specificity (using a grade-2 cut-off) was 98.9% (274/277; 95% confidence interval [CI] 96.9-99.8). Among TB cases, positive urine-LAM status was strongly associated with mortality at 90 days (adjusted hazard ratio 4.20; 95% CI 1.50-11.75). Routine testing for TB in newly admitted HIV-positive adults using Determine TB-LAM to test urine provides major incremental diagnostic yield with very high specificity when used in combination with sputum testing and has important utility among those without respiratory TB symptoms and/or unable to produce sputum. The assay also rapidly identifies individuals with a poor prognosis.
Holden, Brad; Guice, Erica A
2014-05-01
In clinical and forensic toxicology laboratories, one commonly used method for urine specimen validity testing is creatinine concentration. In this study, workplace guidelines are examined to determine their relevance to forensic and clinical toxicology samples. Specifically, it investigates the occurrence of urine creatinine concentrations under 20 mg/dL and notes potential issues with factors influencing creatinine concentration by utilizing a simple, novel method consisting of cation-paring high-pressure liquid chromatography in tandem with ultraviolet detection to determine the creatinine concentration in 3019 donors. Of the 4227 sample population in this study, 209 (4.94%) were below the cutoff value of 20 mg/dL for dilute urine. Because there are many factors that can influence the urinary creatinine concentration, samples that have creatinine under the 20 mg/dL cutoff do not always implicate sample adulteration. © 2014 American Academy of Forensic Sciences.
Zhou, Ying; Chen, Jing; Wang, Zhen
2017-01-01
Objectives. To discuss the characteristics of the amount of urinary total antioxidants in tumor diseases and the possibility of utilizing the changing regulation of urinary antioxidants to diagnose tumor diseases. Method. Urine and serum specimens from 130 healthy people were used to investigate the variation of antioxidant capacity against age. Urine and serum specimens from 44 unselected patients with tumors and 44 healthy people with same age background were used to explore the significance of urinary antioxidant capacity in clinic to diagnose tumor diseases. Potassium permanganate agar method and iodine starch method were used to determine the amount of total antioxidants. Results. In healthy people, more antioxidants in urine were measured in older people, while the results were opposite in serum. More antioxidants were found in urine of tumor patients than in healthy people with same age-range. Conclusions. According to the results of 130 measurements, the amount of antioxidants in urine varies by age. By using agar methods to measure antioxidants, the effect of age is required to be considered. Antioxidants levels from tumor patients were significantly higher than healthy individuals in urine. The combination of urine and serum to determine total antioxidants can better diagnose tumor diseases based on iodine starch method, with area under the receiver operating characteristics curve at 0.787. PMID:28458777
Chaidas, Konstantinos; Tsaoussoglou, Marina; Theodorou, Emmanouel; Lianou, Loukia; Chrousos, George; Kaditis, Athanasios G
2014-08-01
Obstructive sleep apnea (OSA) in childhood is accompanied by sympathetic overflow unopposed by the parasympathetic tone. Complex methods like power spectral analysis of heart rate variability have been applied to study this imbalance. In this report, width of Poincaré scattergram of the R-R interval (parasympathetic tone) and morning urine norepinephrine concentration (sympathetic activity) were used to assess autonomic imbalance. Poincaré plot was obtained from the electrocardiographic channel of nocturnal polysomnography and its width was measured, and norepinephrine-to-creatinine concentration ratio was calculated in morning urine specimen. Twenty children with obstructive sleep apnea and moderate-to-severe nocturnal hypoxemia (oxygen saturation of hemoglobin [SpO(2)] nadir <90%), 24 subjects with mild hypoxemia (SpO(2) nadir ≥90%), and 11 control subjects were recruited. Children with obstructive sleep apnea and moderate-to-severe hypoxemia had significantly narrower Poincaré plot width (318.7 ± 139.3 ms) and higher ln-transformed urine norepinephrine-to-creatinine ratio (4.5 ± 0.6) than control subjects (484.2 ± 104.4 ms and 3.8 ± 0.4, respectively; P < 0.05). Ln-transformed urine norepinephrine levels were inversely related to Poincaré plot width (P = 0.02). Subjects with obstructive sleep apnea and moderate-to-severe nocturnal hypoxemia have enhanced sympathetic activity and reduced parasympathetic drive. Poincaré plot width and urine norepinephrine levels are simple measures of autonomic imbalance in pediatric obstructive sleep apnea. Copyright © 2014 Elsevier Inc. All rights reserved.
Prevalence of BK virus replication among recipients of solid organ transplants.
Muñoz, Patricia; Fogeda, Marta; Bouza, Emilio; Verde, Eduardo; Palomo, Jesus; Bañares, Rafael
2005-12-15
BK virus (BKV) has been implicated as a cause of nephritis and graft loss in 2%-9% of kidney transplant recipients, but the prevalence among recipients of other solid organ transplants (SOTs) has not been well established. Our objective was to determine the prevalence of BKV infection for all types of SOT recipients at our medical center. A total of 156 consecutive SOT recipients were studied, of whom 49 received kidney transplants, 43 received heart transplants, and 64 received liver transplants. Samples were obtained a median of 559 days (range, 1-9481 days) after transplantation. Nested polymerase chain reaction was performed for detection of BKV DNA in urine and plasma specimens. BKV was found in 19% of urine specimens and 6% of plasma specimens. The prevalence of viruria after kidney, heart, and liver transplantation was 26.5%, 25.5%, and 7.8%, respectively. BKV viremia was detected in 12.2% of kidney transplant recipients and 7% of heart transplant recipients. Mean creatinine levels were higher in patients with BKV viruria or viremia (1.9 and 3.5 mg/dL, respectively) than in patients with no BKV replication (1.3 mg/dL). Independent factors related to impaired renal function were renal transplantation (odds ratio [OR], 14.4); BKV replication, including viruria or viremia (OR, 3.3); and mycophenolate use (OR, 2.6). BKV is common in all types of SOT recipients, particularly those who have received heart or kidney transplants.
Kunkel, Frank; Fey, Elizabeth; Borg, Damon; Stripp, Richard; Getto, Christine
2015-01-01
Drug testing is an important clinical tool that is available to physicians who are assessing the effectiveness of drug treatment as well as patient compliance to the administered program. While urine has traditionally been the matrix of choice for drug monitoring, oral fluid, a filtrate of the blood, has shown great promise as an alternative matrix for such applications. Oral fluid collection can be accomplished without the need for highly trained medical staff through the use of a simple, noninvasive oral fluid collection device, which obtains an adequate sample in only a few minutes. There has been a significant amount of research performed on the use of oral fluid for forensic toxicology application; however, more studies assessing the use of oral fluid drug testing are required to validate its ability to achieve clinical drug monitoring goals. Testing for various drugs in oral fluid may yield a different result when compared to the same drugs in urine, requiring an assessment of the utility of oral fluid for such practices. The purpose of this study was to examine the application of oral fluid drug testing in patients undergoing buprenorphine treatment for opioid dependence. A retrospective analysis of drug testing results obtained from 6,928 patients (4,560 unobserved urine collections and 2,368 observed oral fluid collections) monitored for heroin metabolite, amphetamine, benzodiazepines, buprenorphine, tetrahydrocannabinol, cocaine, codeine, hydrocodone, hydromorphone, methadone, morphine, oxycodone, and oxymorphone was completed. Results of this statistical exercise indicated that patients undergoing observed oral fluid collection tested positive more frequently than those unobserved urine collections for several illicit drugs and prescription medications targeted. Oral fluid was shown to detect illicit drug use as well as noncompliance in this patient population under the studied conditions more often than the urine specimens.
Shayanfar, Noushin; Tobler, Ulrich; von Eckardstein, Arnold; Bestmann, Lukas
2007-01-01
Automated analysis of insoluble urine components can reduce the workload of conventional microscopic examination of urine sediment and is possibly helpful for standardization. We compared the diagnostic performance of two automated urine sediment analyzers and combined dipstick/automated urine analysis with that of the traditional dipstick/microscopy algorithm. A total of 332 specimens were collected and analyzed for insoluble urine components by microscopy and automated analyzers, namely the Iris iQ200 (Iris Diagnostics) and the UF-100 flow cytometer (Sysmex). The coefficients of variation for day-to-day quality control of the iQ200 and UF-100 analyzers were 6.5% and 5.5%, respectively, for red blood cells. We reached accuracy ranging from 68% (bacteria) to 97% (yeast) for the iQ200 and from 42% (bacteria) to 93% (yeast) for the UF-100. The combination of dipstick and automated urine sediment analysis increased the sensitivity of screening to approximately 98%. We conclude that automated urine sediment analysis is sufficiently precise and improves the workflow in a routine laboratory. In addition, it allows sediment analysis of all urine samples and thereby helps to detect pathological samples that would have been missed in the conventional two-step procedure according to the European guidelines. Although it is not a substitute for microscopic sediment examination, it can, when combined with dipstick testing, reduce the number of specimens submitted to microscopy. Visual microscopy is still required for some samples, namely, dysmorphic erythrocytes, yeasts, Trichomonas, oval fat bodies, differentiation of casts and certain crystals.
Luong, Susan; Fu, Shanlin
2014-03-01
In vitro urine adulteration is a well-documented practice adopted by individuals aiming to evade detection of drug use, when required to undergo mandatory sports and workplace drug testing. Potassium nitrite is an effective urine adulterant due to its oxidizing potential, and has been shown to mask the presence of many drugs of abuse. However, limited research has been conducted to understand its mechanism of action, and to explore the possibility of the drugs undergoing direct oxidation to form stable reaction products. In this study, opiates including morphine, codeine, morphine-3-glucuronide and morphine-6-glucuronide were exposed to potassium nitrite in water and urine to mimic the process of nitrite adulteration. It was found that two stable reaction products were detected by liquid chromatography-mass spectrometry (LC-MS) when morphine and morphine-6-glucuronide were exposed to nitrite. Isolation and elucidation using spectrometric and spectroscopic techniques revealed that they were 2-nitro-morphine and 2-nitro-morphine-6-glucuronide, respectively. These reaction products were also formed when an authentic morphine-positive urine specimen was fortified with nitrite. 2-Nitro-morphine was found to be stable enough to undergo the enzymatic hydrolysis procedure and also detectable by gas chromatography-mass spectrometry (GC-MS) after forming a trimethylsilyl derivative. On the contrary, morphine-3-glucuronide did not appear to be chemically manipulated when exposed to potassium nitrite in urine. These reaction products are not endogenously produced, are relatively stable and can be monitored with both LC-MS and GC-MS confirmatory techniques. As a result, these findings have revealed the possibility for the use of 2-nitro-morphine and 2-nitro-morphine-6-glucuronide as markers for the indirect monitoring of morphine and morphine-6-glucuronide in urine specimens adulterated with nitrite. Copyright © 2013 John Wiley & Sons, Ltd.
Mushanski, Linda M; Brandt, Ken; Coffin, Nicolette; Levett, Paul N; Horsman, Gregory B; Rank, Elliot L
2012-07-01
Performances of the BD ProbeTec Chlamydia trachomatis (CT)/Neisseria Gonorrhoeae (GC) Q(x) Amplified DNA Assay reagents on a BD Viper System with XTR Technology and APTIMA COMBO 2 Assay reagents on a TIGRIS DTS platform, for detection of both CT and GC were compared. A total of 1018 first-void urine specimens were tested for the presence of CT and GC DNA using the 2 assays. CT was detected in 143 specimens (14%). Eight specimens exhibited discordant results, and they were divided equally between the 2 assays. Based on the original results, the overall agreement for CT was 99.2%, with 97.1% and 99.5% in agreement with positive and negative specimens, respectively. Cohen's Kappa was 0.967. GC was detected in 27 specimens (2.6%). Two specimens exhibited discordant results, and they were divided equally between the 2 assays. Based on the original results, the overall agreement was 99.8%, with 96.2% and 99.9% in agreement for positive and negative specimens, respectively. Cohen's Kappa was 0.961. There was a high level of agreement between the systems for both CT and GC detection.
Lower Cutoffs for LC-MS/MS Urine Drug Testing Indicates Better Patient Compliance.
Krock, Kevin; Pesce, Amadeo; Ritz, Dennis; Thomas, Richard; Cua, Agnes; Rogers, Ryan; Lipnick, Phil; Kilbourn, Kristen
2017-11-01
Urine drug testing is used by health care providers to determine a patient's compliance to their prescribed regimen and to detect non-prescribed medications and illicit drugs. However, the cutoff levels used by clinical labs are often arbitrarily set and may not reflect the urine drug concentrations of compliant patients. Our aim was to test the hypothesis that commonly used cutoffs for many prescribed and illicit drugs were set too high, and methods using these cutoffs may yield a considerable number of false-negative results. The goals of this study were to outline the way to analyze patient results and estimate a more appropriate cutoff, develop and validate a high sensitivity analytical method capable of quantitating drugs and metabolites at lower than the commonly used cutoffs, and determine the number of true positive results that would have been missed when using the common cutoffs. This was a retrospective study of urine specimens submitted for urine drug testing as part of the monitoring of prescription drug compliance described in chronic opioid therapy treatment guidelines. The study was set in a clinical toxicology laboratory, using specimens submitted for routine analysis by health care providers in the normal course of business. Lognormal distributions of test results were generated and fitted with a trendline to estimate the required cutoff level necessary to capture the normal distributions of each drug for the patient population study. A validated laboratory derived liquid chromatography tandem mass spectrometry (LC-MS/MS) analysis capable of achieving the required cutoff levels was developed for each drug and/or metabolite. The study shows that a lognormal distribution of patient urine test results fitted with a trendline is appropriate for estimating the required cutoff levels needed to assess medication adherence. The study showed a wide variation in the false-negative rate, ranging from 1.5% to 94.3% across a range of prescribed and illicit drugs. The patient specimens were largely sourced from patients in either a long-term pain management program or in treatment for substance use disorder in the US. These specimens may not be representative of patients in other types of treatment or in countries with different approaches to these issues. The high-sensitivity method reduces false-negative results which could negatively impact patient care. Clinicians using less sensitive methods for detecting and quantifying drugs and metabolites in urine should exercise caution in assessing patient adherence using and changing the treatment plan based on those results. Urine drug testing, patient adherence, clinical toxicology, immunoassay, LC-MS, definitive drug testing, REMS, negative test results, false negative.
Evaluation of a nested-PCR for mycobacterium tuberculosis detection in blood and urine samples.
da Cruz, Heidi Lacerda Alves; de Albuquerque Montenegro, Rosana; de Araújo Lima, Juliana Falcão; da Rocha Poroca, Diogo; da Costa Lima, Juliana Figueirêdo; Maria Lapa Montenegro, Lílian; Crovella, Sergio; Charifker Schindler, Haiana
2011-01-01
The polymerase chain reaction (PCR) and its variations, such as the nested-PCR, have been described as promising techniques for rapid diagnosis of tuberculosis (TB). With the aim of evaluating the usefulness of a nested-PCR method on samples of blood and urine of patients suspected of tuberculosis we analyzed 192 clinical samples, using as a molecular target the insertion element IS6110 specific of M. tuberculosis genome. Nested-PCR method showed higher sensitivity in patients with extrapulmonary tuberculosis (47.8% and 52% in blood and urine) when compared to patients with the pulmonary form of the disease (sensitivity of 29% and 26.9% in blood and urine), regardless of the type of biological sample used. The nested-PCR is a rapid technique that, even if not showing a good sensitivity, should be considered as a helpful tool especially in the extrapulmonary cases or in cases where confirmatory diagnosis is quite difficult to be achieved by routine methods. The performance of PCR-based techniques should be considered and tested in future works on other types of biological specimens besides sputum, like blood and urine, readily obtainable in most cases. The improving of M. tuberculosis nested-PCR detection in TB affected patients will give the possibility of an earlier detection of bacilli thus interrupting the transmission chain of the disease.
Siza, Julius E; Kaatano, Godfrey M; Chai, Jong-Yil; Eom, Keeseon S; Rim, Han-Jong; Yong, Tai-Soon; Min, Duk-Young; Chang, Su Young; Ko, Yunsuk; Changalucha, John M
2015-10-01
The objective of this study was to carry out a community survey on schistosomiais and soil-transmitted helminth (STH) infections in order to suggest feasible and effective intervention strategies in Lake Victoria basin, Tanzania. A total of 37 communities selected from 23 districts of the 4 regions in the Lake Victoria basin of Tanzania were involved in the study. From each of the selected locality, 50 adult community members, 25 males and 25 females, were recruited for the study. Each study participant was requested to submit stool and urine specimens. From each stool specimen, duplicate Kato-Katz thick smears were prepared and microscopically examined for Schistosoma mansoni and STH eggs. Urine specimens were processed by the filtration technique and microscopically examined for Schistosoma haematobium eggs. Ultrasound examination for morbidity due to schistosomiasis was performed. Mass treatment was done using praziquantel and albendazole for schistosome and STHs infections, respectively. Out of 1,606 adults who provided stool specimens, 199 (12.4%) were positive for S. mansoni, 349 (21.7%) for hookworms, 133 (8.3%) for Ascaris lumbricoides, and 33 (2.0%) for Trichuris trichiura. Out of 1,400 participants who provided urine specimens, 25 (1.8%) were positive for S. haematobium eggs. Because of the co-endemicity of these afflictions and their impact on vulnerable population groups, the helminthiasis could be simultaneously treated with 2 drugs, praziquantel for schistosomiasis and albendazole for STHs.
Palyi, Bernadett; Magyar, Nora; Henczko, Judit; Szalai, Balint; Farkas, Agnes; Strecker, Thomas; Takacs, Maria; Kis, Zoltan
2018-03-29
In 2013-2016, West Africa experienced the largest and longest Ebola virus disease outbreak ever documented. The wide geographic spread and magnitude of the outbreak often limited the timely and rapid testing of diagnostic samples from patients with suspected Ebola virus disease, raising questions regarding the optimal storage and shipping conditions of clinically relevant specimens, including EDTA-whole blood, plasma, capillary blood, urine and seminal fluid (associated with sexual transmission of the Ebola virus after recovery from the disease). Therefore, the aim of our study was to identify the extent to which storage temperature and clinical specimen type influence Ebola virus viability. Virus infectivity was determined using a fluorescent focus-forming assay. In our study, we show that Ebola virus was the most stable in EDTA-whole blood and plasma samples, whereas rapid decay of infectivity was observed in simulated capillary blood, urine and semen samples, especially when these samples were stored at higher temperatures. The analysis of variance results demonstrated that both temperature and clinical specimen type have significant effects on virus viability, whereas donor differences were not observed. Repeated freeze and thaw cycles of the samples also had a notable impact on virus viability in EDTA-whole blood and urine. Due to the rapid temperature- and specimen-dependent degradation of the virus observed here, our study highlights the importance of proper clinical sample storage at low temperatures during transportation and laboratory analysis.
Preston, K L; Umbricht, A; Epstein, D H
2000-04-01
Although methadone maintenance is an effective therapy for heroin dependence, some patients continue to use heroin and may benefit from therapeutic modifications. This study evaluated a behavioral intervention, a pharmacological intervention, and a combination of both interventions. Throughout the study all patients received daily methadone hydrochloride maintenance (initially 50 mg/d orally) and weekly counseling. Following baseline treatment patients who continued to use heroin were randomly assigned to 1 of 4 interventions: (1) contingent vouchers for opiate-negative urine specimens (n = 29 patients); (2) methadone hydrochloride dose increase to 70 mg/d (n = 31 patients); (3) combined contingent vouchers and methadone dose increase (n = 32 patients); and (4) neither intervention (comparison standard; n = 28 patients). Methadone dose increases were double blind. Vouchers had monetary value and were exchangeable for goods and services. Groups not receiving contingent vouchers received matching vouchers independent of urine test results. Primary outcome measure was opiate-negative urine specimens (thrice weekly urinalysis). Contingent vouchers and a methadone dose increase each significantly increased the percentage of opiate-negative urine specimens during intervention. Contingent vouchers, with or without a methadone dose increase, increased the duration of sustained abstinence as assessed by urine screenings. Methadone dose increase, with or without contingent vouchers, reduced self-reported frequency of use and self-reported craving. In patients enrolled in a methadone-maintainence program who continued to use heroin, abstinence reinforcement and a methadone dose increase were each effective in reducing use. When combined, they did not dramatically enhance each other's effects on any 1 outcome measure, but they did seem to have complementary benefits.
Ybarra, Winnie L; Sykes, Jane E; Wang, Yenlie; Byrne, Barbara A; Westropp, Jodi L
2014-04-01
To evaluate the performance of a veterinary urine dipstick paddle (UDP) for diagnosis and identification of urinary tract infection (UTI) in dogs and cats. Prospective, randomized, blinded study. 207 urine specimens. UDPs were inoculated by 2 investigators and incubated according to manufacturer's instructions. Results, including presence or absence of bacterial growth, organism counts, and identification of uropathogens, were compared between investigators and with microbiology laboratory results. A subset of UDPs with bacterial growth was submitted to the laboratory for confirmation. The laboratory reported 64 (30.9%) specimens had growth of bacteria. Bacterial growth was reported for 63 (30.4%) and 58 (28.0%) of the UDPs by investigators 1 and 2, respectively. Sensitivity and specificity of the UDP for detection of bacterial growth were 97.3% and 98.6%, respectively, for investigator 1 and 89.1% and 99.3%, respectively, for investigator 2. For UPDs with ≥ 10(5) colony-forming units/mL, organism counts correlated well between the laboratory and investigators 1 (r = 0.95) and 2 (r = 0.89). Pathogen identification was not always accurate. Only 25 of 33 (75.8%) UDPs submitted for confirmation yielded bacteria consistent with those isolated from the original bacterial culture of urine. The veterinary UDP system was a sensitive test for screening patients for bacterial UTI, but uropathogen identification was not always accurate. When UDPs have bacterial growth, a fresh urine specimen should be submitted to the laboratory to confirm the identity of the organisms and to permit antimicrobial susceptibility testing.
Microbiological and corrosion analysis of three urine pretreatment regimes with titanium 6A1-4V
NASA Technical Reports Server (NTRS)
Huff, Timothy L.
1993-01-01
One objective of the water recovery test (WRT) performed at NASA's Marshall Space Flight Center (MSFC) for the environmental control and life support systems (ECLSS) of Space Station Freedom is to determine the ability of the water recovery system to reclaim urine for crew reuse. In the process, raw urine is pretreated using a commercially available oxidant, Oxone (Dupont), and sulfuric acid (to reduce ammonia), and pumped into a urine processing subsystem. A combination of sodium hypochlorite and sulfuric acid were also considered as an alternative pretreatment. The ability of these pretreatments, plus a third pretreatment of ozone, to reduce microbial levels in urine generated during testing of the water recovery system at MSFC was examined. In addition, the corrosion rate of weld and base metal specimens of titanium 6A1-4V, a candidate material for the water system of Space Station Freedom, was monitored in the presence of these pretreatments. Specimen surfaces were examined at completion of the 21-day test using scanning electron microscopy. Change in pH, color, turbidity, and odor were recorded over the course of the test.
The measurement of radiation exposure of astronauts by radiochemical techniques
NASA Technical Reports Server (NTRS)
Brodzinski, R. L.
1972-01-01
Cosmic radiation doses to the crews of the Apollo 14, 15, and 16 missions of 142 + or - 80, 340 + or - 80, and 210 + or - 130 mR respectively were calculated from the specific activities of Na-22 and Na-24 in the postflight urine specimens of the astronauts. The specific activity of Fe-59 was higher in the urine than in the feces of the Apollo 14 and 15 astronauts, and a possible explanation is given. The concentrations of K-40, K-42, Cr-51, Co-60, and Cs-137 in the urine are also reported for these astronauts. The radiation doses received by pilots and navigators flying high altitude missions during the solar flare of March 27 to 30, 1972 were calculated from the specific activity of Na-24 in their urine. These values are compared with the expected radiation dose calculated from the known shape and intensity of the proton spectrum and demonstrate the magnitude of atmospheric shielding. The concentrations of Na, K, Rb, Cs, Fe, Co, Ag, Zn, Hg, As, Sb, Se, and Br were measured in the urine specimens from the Apollo 14 and 15 astronauts by neutron activation analysis. The mercury and arsenic levels were much higher than expected.
Quantitative Urine Culture Method Using a Plastic „Paddle” Containing Dual Media
Craig, William A.; Kunin, Calvin M.
1972-01-01
A new dip-inoculum method for quantitative urine culture is described which utilizes a dual-chambered plastic „paddle” housing both a general purpose and differential medium. Comparative bacterial counts of 1,000 clinical specimens using the pour plate and this device were identical in 82.9% and within a factor of five in 95.6%. The „paddle” detected all but 19 of 258 specimens (92.6%) with 100,000 or greater colonies per ml. This simple, convenient method should allow more extensive use of quantitative urine culture in the diagnosis and follow-up of patients with urinary tract infections in office practice. It should not be considered as a substitute for the more definitive pour plate method or for standard methods for characterization of bacteriological species when more exact information is required. PMID:4555636
PROFILES OF GREAT LAKES CRITICAL POLLUTANTS: A SENTINEL ANALYSIS OF HUMAN BLOOD AND URINE
To determine the contaminants that should be studied further in the subsequent population-based study, a profile of Great Lakes (GL) sport fish contaminant residues were studied in human blood and urine specimens from 32 sport fish consumers from three Great Lakes: Lake Michigan ...
In vitro results with special plastics for biodegradable endoureteral stents.
Schlick, R W; Planz, K
1998-10-01
Internal ureteral stents are widely used in urologic practice for temporary urinary diversion, but all double-J catheters to date exhibit the same disadvantage; that is, they have to be removed endoscopically, necessitating further intervention. We tested different materials (designated G100X-15xLB and G100X-20xLB) to develop a biodegradable (biodissolvable) endoureteral stent that can be held in place without functional loss yet could be dissolved by changing the environment. The principle of the biochemical background is based on the physiological milieu of the urine. The plastics tested are stable in acidic and dissolve in alkaline conditions. In a first step, specimens of two polymers were placed in artificial urine of different pH over a period of 60 days and monitored for integrity (solution trial). In a second step, artificial urine was set in motion (744 mL/24 hours) an infusion pump (Volumed microVP 5000; Fresenius AG, Bad Homburg vdH, Germany) through an infusion set in which a 30-cm piece of the materials to test had been placed (ureter model). Below the inserted specimen, the lumen of the infusion tube was minimized to make obstruction by fragments more possible. In the solution trial, all specimens remained stable under physiologic conditions (pH 5.2) over a period of at least 30 days. The specimens dissolved completely when the pH was adjusted to an alkaline one (pH 7.9). In the ureter model, with pH values of 7.9, all specimens were decomposed after 20 hours, and no occlusion of the model occurred. Using acidic artificial urine, the specimens remained stable with a smooth consistent surface. The dissolution was not a standard chemical one; the materials broke into microscopically small pieces, with fragments of G100X-20xLB being smaller than those of G100X-15xLB. Our first in vitro results show that the tested materials are suitable for further development of biodissolvable endoureteral stents, dissolution of which can be steered by changing the urinary pH.
CHANGES IN URINE MARKERS AND SYMPTOMS AFTER BLADDER DISTENTION FOR INTERSTITIAL CYSTITIS
Erickson, Deborah R.; Kunselman, Allen R.; Bentley, Christina M.; Peters, Kenneth M.; Rovner, Eric S.; Demers, Laurence M.; Wheeler, Marcia A.; Keay, Susan K.
2008-01-01
Purpose To evaluate changes in urine markers and symptom scores after bladder distention in interstitial cystitis (IC) patients. Materials and Methods Subjects were 33 new patients with no prior IC treatments. Urine specimens were taken before and one month after bladder distention. University of Wisconsin (UW) symptom scores were done the same day as the urine specimen collection. Urine marker levels and symptom scores before and after distention were compared. Changes in markers were tested for associations with changes in symptom scores and other markers. Pre-distention markers and specific pre-distention symptoms were tested for their association with post-distention symptom improvement. Results After distention, the median total UW score decreased significantly (28.5 before, 10 after, p<0.001). Twelve patients (36%) had at least 30% improvement in UW score, and eight patients (24%) had at least 50% improvement. No pre-distention markers or symptoms predicted which patients would have a good response. Two of the urine markers improved significantly after distention: anti-proliferative factor (APF) activity (median −96% before, −17% after, p< 0.001) and heparin binding-epidermal growth factor-like growth factor (HB-EGF) levels (median 0.34 ng/mg creatinine before, 4.1 after, p<0.001). None of the changes in urine markers associated with changes in symptom scores. Conclusions The median symptom score for newly diagnosed IC patients decreased after distention, but only a minority of patients had at least 30% symptom improvement. Bladder distention altered urine APF activity and HB-EGF levels towards normal, but the mechanism of symptom relief after distention is still unknown. PMID:17222633
Coorevits, L; Heytens, S; Boelens, J; Claeys, G
2017-04-01
The workup and interpretation of urine cultures is not always clear-cut, especially for midstream samples contaminated with commensals. Standard urine culture (SUC) protocols are designed in favor of growth of uropathogens at the expense of commensals. In selected clinical situations, however, it is essential to trace fastidious or new uropathogens by expanding the urine culture conditions (EUC). The aim of our study was to map the microflora in midstream urine specimens from healthy controls by means of EUC, in view of the interpretation of bacterial culture results in symptomatic patients. Midstream urine specimens from 101 healthy controls (86 females and 15 males) were examined using both SUC and EUC. Whilst 73 % of samples examined by SUC showed no growth at 10 3 colony-forming units (CFU)/mL, 91 % of samples examined by EUC grew bacterial species in large numbers (≥10 4 CFU/mL). Asymptomatic bacteriuria, as defined by the European guidelines for urinalysis, was detected in six samples with both protocols. EUC revealed 98 different species, mostly Lactobacillus, Staphylococcus, Streptococcus, and Corynebacterium. None of the samples grew Staphylococcus saprophyticus, Corynebacterium urealyticum, or Aerococcus urinae. Samples from females contained higher bacterial loads and showed higher bacterial diversity compared to males. Midstream urine of healthy controls contains large communities of living bacteria that comprise a resident microflora, only revealed by EUC. Hence, the use of EUC instead of SUC in a routine setting would result in more sensitive but less specific results, requiring critical interpretation. In our view, EUC should be reserved for limited indications.
[Is bacteriological testing of bladder urine informative in acute obstructive pyelo- nephritis?
Kogan, M I; Naboka, Yu L; Bedzhanyan, S K; Mitusova, E V; Gudima, I A; Morgun, P P; Vasileva, L I
2017-07-01
The problem of the etiology and pathogenesis of acute obstructive pyelonephritis (OOP) remains one of the challenging issues of modern urology. Etiological agents of pyelonephritis can be both gram-negative and gram-positive opportunistic bacteria mostly belonging to the normal flora in humans. The generally accepted diagnostic work-up involves a bacteriological testing of not pelvic urine, but of bladder urine collected by a transurethral catheter or midstream specimens of urine collected from the patients. The aim of our study was to compare the microbiota of bladder and pelvic urine in patients with OOP. The study comprised 72 sequentially selected patients (12 men and 60 women) with OOP associated with ureteral stones. Mean age of patients was 53.7+/-0.5 years. All patients underwent bacteriological examination of the bladder urine collected by a transurethral catheter and pelvic urine obtained after relieving stone-related ureteral obstruction. Urinary diversion was performed using j-j stent and PCN in 64 and 8 patients, respectively. Preoperative prophylactic antibiotics were administered routinely. Bacteriological testing of urine was carried out using an extended set (9-10) of culture media. Empirical antibiotic therapy was initiated only after the restoration of urine outflow from the kidney and continued for 5-6 days until the availability of bacteriological testing results. Levels of bacteriuria with Enterobacteria, gram-positive pathogens and NAB in two urine samples did not differ significantly (p>0.05). There was a wide range of bacteriuria from 101 to 106 CFU/ml of most microorganisms except @Proteus spp., S. aureus. In bladder urine, the rates of bacteriuria of more or equal 104 CFU/ml for E. coli, Klebsiella spp. and Proteus spp. were 90.9%, 72.7% and 100.0%, respectively. For the remaining microorganisms, predominant bacteriuria was less or equal 103 CFU/ml. In pelvic urine, the rates of bacteriuria of more or equal 104 CFU/ml for E. coli, Klebsiella spp. and Proteus spp. was 71.8%, 40.0% and 66.7%, respectively. Other uropathogens in the pelvic urine mainly had a bacterial count of less or equal 103 CFU/ml. Only the concentration of Corynebacterium spp. in the pelvic urine significantly (p=0.023) differed from that of the bladder urine. There were no significant differences between microbiota of bladder and pelvic urine depending on duration of OOP except higher rates of Corynebacterium spp. in the bladder urine.
In Vitro and In Vivo Human Metabolism of Synthetic Cannabinoids FDU-PB-22 and FUB-PB-22.
Diao, Xingxing; Scheidweiler, Karl B; Wohlfarth, Ariane; Pang, Shaokun; Kronstrand, Robert; Huestis, Marilyn A
2016-03-01
In 2014, FDU-PB-22 and FUB-PB-22, two novel synthetic cannabinoids, were detected in herbal blends in Japan, Russia, and Germany and were quickly added to their scheduled drugs list. Unfortunately, no human metabolism data are currently available, making it challenging to confirm their intake. The present study aims to identify appropriate analytical markers by investigating FDU-PB-22 and FUB-PB-22 metabolism in human hepatocytes and confirm the results in authentic urine specimens. For metabolic stability, 1 μM FDU-PB-22 and FUB-PB-22 was incubated with human liver microsomes for up to 1 h; for metabolite profiling, 10 μM was incubated with human hepatocytes for 3 h. Two authentic urine specimens from FDU-PB-22 and FUB-PB-22 positive cases were analyzed after β-glucuronidase hydrolysis. Metabolite identification in hepatocyte samples and urine specimens was accomplished by high-resolution mass spectrometry using information-dependent acquisition. Both FDU-PB-22 and FUB-PB-22 were rapidly metabolized in HLM with half-lives of 12.4 and 11.5 min, respectively. In human hepatocyte samples, we identified seven metabolites for both compounds, generated by ester hydrolysis and further hydroxylation and/or glucuronidation. After ester hydrolysis, FDU-PB-22 and FUB-PB-22 yielded the same metabolite M7, fluorobenzylindole-3-carboxylic acid (FBI-COOH). M7 and M6 (hydroxylated FBI-COOH) were the major metabolites. In authentic urine specimens after β-glucuronidase hydrolysis, M6 and M7 also were the predominant metabolites. Based on our study, we recommend M6 (hydroxylated FBI-COOH) and M7 (FBI-COOH) as suitable urinary markers for documenting FDU-PB-22 and/or FUB-PB-22 intake.
Lohiya, Ayush; Kapil, Arti; Gupta, Sanjeev Kumar; Misra, Puneet; Rai, Sanjay K.
2015-01-01
Background Despite world-wide evidence of increased antibiotic resistance, there is scarce data on antibiotic resistance in community settings. One of the reason being difficulty in collection of biological specimen (traditionally stool) in community from apparently healthy individuals. Hence, finding an alternative specimen that is easier to obtain in a community setting or in large scale surveys for the purpose, is crucial. We conducted this study to explore the feasibility of using urine samples for deriving community based estimates of antibiotic resistance and to estimate the magnitude of resistance among urinary isolates of Escherichia coli and Klebsiella pneumonia against multiple antibiotics in apparently healthy individuals residing in a rural community of Haryana, North India. Materials and Methods Eligible individuals were apparently healthy, aged 18 years or older. Using the health management information system (HMIS) of Ballabgarh Health Demographic Surveillance System (HDSS), sampling frame was prepared. Potential individuals were identified using simple random sampling. Random urine sample was collected in a sterile container and transported to laboratory under ambient condition. Species identification and antibiotic susceptibility testing for Enterobacteriaceae was done using Clinical Laboratory and Standards Institute (CLSI) 2012 guidelines. Multi-drug resistant (MDR) Enterobacteriaceae, Extended Spectrum Beta Lactamase (ESBL) producing Enterobacteriaceae, and Carbapenem producing Enterobacteriaceae (CRE) were identified from the urine samples. Results A total of 433 individuals participated in the study (non-response rate – 13.4%), out of which 58 (13.4%) were positive for Enterobacteriaceae, 8.1% for E. coli and 5.3% for K. pneumoniae. Resistance against penicillin (amoxicillin/ampicillin) for E. coli and K. pneumoniae was 62.8% and 100.0% respectively. Isolates resistant to co-trimoxazole were 5.7% and 0.0% respectively. None of the isolates were resistant to imipenem, and meropenem. Conclusion and recommendations It is feasible to use urine sample to study magnitude of antibiotic resistance in population based surveys. At community level, resistance to amoxicillin was considerable, negligible for co-trimoxazole, and to higher antibiotics including carbapenems. PMID:26393150
Urinary concentrations of morphine and codeine after consumption of poppy seeds.
Thevis, Mario; Opfermann, Georg; Schänzer, Wilhelm
2003-01-01
A quantitative analysis of morphine and codeine in human urine was performed after oral intake of cakes containing commercially available poppy seeds in order to estimate the possibility of positive doping results. Therefore, eight products from different manufacturers (poppy seeds or baking mixtures) and origin were obtained and analyzed by gas chromatography-mass spectrometry for the presence of the alkaloids. One selected batch of poppy seeds was used as an ingredient in a typical cake and was the object of an excretion study with nine volunteers. After application, several urine specimens contained morphine with concentrations higher than 1 microg/mL, and peak values of approximately 10.0 microg/mL were detected. Because the International Olympic Committee set a cutoff limit for morphine at 1 microg/mL, high-performance athletes could possibly test positive in doping control after consumption of products containing poppy seeds.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-03
... Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for Federal... Guidelines for Federal Workplace Drug Testing Programs (Mandatory Guidelines). The Mandatory Guidelines were... Laboratories and Instrumented Initial Testing Facilities (IITF) must meet in order to conduct drug and specimen...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-13
... Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for Federal... Guidelines for Federal Workplace Drug Testing Programs (Mandatory Guidelines). The Mandatory Guidelines were... and Instrumented Initial Testing Facilities (IITF) must meet in order to conduct drug and specimen...
Montgomery, Sandra; Roman, Kiana; Ngyuen, Lan; Cardenas, Ana Maria; Knox, James; Tomaras, Andrew P.
2017-01-01
ABSTRACT Urinary tract infections are one of the most common reasons for health care visits. Diagnosis and optimal treatment often require a urine culture, which takes an average of 1.5 to 2 days from urine collection to results, delaying optimal therapy. Faster, but accurate, alternatives are needed. Light scatter technology has been proposed for several years as a rapid screening tool, whereby negative specimens are excluded from culture. A commercially available light scatter device, BacterioScan 216Dx (BacterioScan, Inc.), has recently been advertised for this application. Paired use of mass spectrometry (MS) for bacterial identification and automated-system-based susceptibility testing straight from the light scatter suspension might provide dramatic improvement in times to a result. The present study prospectively evaluated the BacterioScan device, with culture as the reference standard. Positive light scatter specimens were used for downstream rapid matrix-assisted laser desorption ionization–time of flight (MALDI-TOF) MS organism identification and automated-system-based antimicrobial susceptibility testing. Prospective evaluation of 439 urine samples showed a sensitivity of 96.5%, a specificity of 71.4%, and positive and negative predictive values of 45.1% and 98.8%, respectively. MALDI-TOF MS analysis of the suspension after density-based selection yielded a sensitivity of 72.1% and a specificity of 96.9%. Antimicrobial susceptibility testing of the samples identified by MALDI-TOF MS produced an overall categorical agreement of 99.2%. Given the high sensitivity and negative predictive value of results obtained, BacterioScan 216Dx is a reasonable approach for urine screening and might produce negative results in as few as 3 h, with no downstream workup. Paired rapid identification and susceptibility testing might be useful when MALDI-TOF MS results in an organism identification, and it might decrease the time to a result by more than 24 h. PMID:28356414
Montgomery, Sandra; Roman, Kiana; Ngyuen, Lan; Cardenas, Ana Maria; Knox, James; Tomaras, Andrew P; Graf, Erin H
2017-06-01
Urinary tract infections are one of the most common reasons for health care visits. Diagnosis and optimal treatment often require a urine culture, which takes an average of 1.5 to 2 days from urine collection to results, delaying optimal therapy. Faster, but accurate, alternatives are needed. Light scatter technology has been proposed for several years as a rapid screening tool, whereby negative specimens are excluded from culture. A commercially available light scatter device, BacterioScan 216Dx (BacterioScan, Inc.), has recently been advertised for this application. Paired use of mass spectrometry (MS) for bacterial identification and automated-system-based susceptibility testing straight from the light scatter suspension might provide dramatic improvement in times to a result. The present study prospectively evaluated the BacterioScan device, with culture as the reference standard. Positive light scatter specimens were used for downstream rapid matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) MS organism identification and automated-system-based antimicrobial susceptibility testing. Prospective evaluation of 439 urine samples showed a sensitivity of 96.5%, a specificity of 71.4%, and positive and negative predictive values of 45.1% and 98.8%, respectively. MALDI-TOF MS analysis of the suspension after density-based selection yielded a sensitivity of 72.1% and a specificity of 96.9%. Antimicrobial susceptibility testing of the samples identified by MALDI-TOF MS produced an overall categorical agreement of 99.2%. Given the high sensitivity and negative predictive value of results obtained, BacterioScan 216Dx is a reasonable approach for urine screening and might produce negative results in as few as 3 h, with no downstream workup. Paired rapid identification and susceptibility testing might be useful when MALDI-TOF MS results in an organism identification, and it might decrease the time to a result by more than 24 h. Copyright © 2017 American Society for Microbiology.
Kacinko, Sherri L.; Jones, Hendree E.; Johnson, Rolley E.; Choo, Robin E.; Concheiro-Guisan, Marta; Huestis, Marilyn A.
2011-01-01
BACKGROUND Buprenorphine (BUP) is under investigation as a medication therapy for opioid-dependent pregnant women. We investigated BUP and metabolite disposition in urine from women maintained on BUP during the second and third trimesters of pregnancy and postpartum. METHODS We measured BUP, norbuprenorphine (NBUP), buprenorphine glucuronide (BUP-Gluc), and NBUP-Gluc concentrations in 515 urine specimens collected thrice weekly from 9 women during pregnancy and postpartum. Specimens were analyzed using a fully validated liquid chromatography-mass spectrometry method with limits of quantification of 5 µg/L for BUP and BUP-Gluc and 25 µg/L for NBUP and its conjugated metabolite. We examined ratios of metabolites across trimesters and postpartum to identify possible changes in metabolism during pregnancy. RESULTS NBUP-Gluc was the primary metabolite identified in urine and exceeded BUP-Gluc concentrations in 99% of specimens. Whereas BUP-Gluc was identified in more specimens than NBUP, NBUP exceeded BUP-Gluc concentrations in 77.9% of specimens that contained both analytes. Among all participants, the mean BUP-Gluc:NBUP-Gluc ratio was significantly higher in the second trimester compared to the third trimester, and there were significant intrasubject differences between trimesters in 71% of participants. In 3 women, the percent daily dose excreted was higher during pregnancy than postpregnancy, consistent with other data indicating increased renal elimination of drugs during pregnancy. CONCLUSIONS These data are the first to evaluate urinary disposition of BUP and metabolites in a cohort of pregnant women. Variable BUP excretion during pregnancy may indicate metabolic changes requiring dose adjustment during later stages of gestation. PMID:19325013
Urine benzodiazepines screening of involuntarily drugged and robbed or raped patients.
Boussairi, A; Dupeyron, J P; Hernandez, B; Delaitre, D; Beugnet, L; Espinoza, P; Diamant-Berger, O
1996-01-01
This study involved 35 patients who claimed to have been drugged before being robbed or raped, despite urine negative toxicologic screening by immunoenzymatic methods. The urines were frozen for further investigations, including enzymatic hydrolysis of urinary conjugates, liquid-solid extraction and, finally, immunoenzymatic screening of concentrated urine extract. Urine benzodiazepines were analyzed by immunoenzymatic assay before and after enzymatic hydrolysis combined with extraction. On direct immunoenzymatic screening, 17 of the 35 urine samples were benzodiazepine positive. Enrichment of preserved specimens improved the detection threshold from 200 ng/mL to 50 ng/mL and 10 of the 18 negative urines became positive. This method allowed us to demonstrate the benzodiazepines in half of previously negative urine samples. Benzodiazepine screening is particularly problematic because of low dosage, rapid elimination, failure to detect conjugated metabolites by immunoenzymatic reagents and high threshold of sensitivity for certain substances.
Struempler, R E; Nelson, G; Urry, F M
1997-01-01
A commercially available health food product of cold-pressed hemp seed oil ingested by one volunteer twice a day for 4 1/2 days (135 mL total). Urine specimens collected from the volunteer were subjected to standard workplace urine drug testing procedures, and the following concentrations of 11-nor-delta9- tetrahydrocannabinol carboxylic acid (9-THCA) were detected: 41 ng/mL 9-THCA at 45 h, 49 ng/mL at 69 h, and 55 ng/mL at 93 h. Ingestion was discontinued after 93 h, and the following concentrations were detected: 68 ng/mL at 108 h, 57 ng/mL at 117 h, 31 ng/mL at 126 h, and 20 ng/mL at 142 h. The first specimen that tested negative (50 ng/mL initial immunoassay test, 15 ng/mL confirmatory gas chromatographic-mass spectrometric test) was at 146 h, which was 53 h after the last hemp seed oil ingestion. Four subsequent specimens taken to 177 h were also negative. This study indicates that a workplace urine drug test positive for cannabinoids may arise from the consumption of commercially available cold-pressed hemp seed oil.
Symptomatic Zika Virus Infection in Infants, Children, and Adolescents Living in Puerto Rico.
Read, Jennifer S; Torres-Velasquez, Brenda; Lorenzi, Olga; Rivera Sanchez, Aidsa; Torres-Torres, Sanet; Rivera, Lillian V; Capre-Franceschi, Sheila M; Garcia-Gubern, Carlos; Munoz-Jordan, Jorge; Santiago, Gilberto A; Alvarado, Luisa I
2018-05-29
Little information is available regarding Zika virus (ZIKV) infection in children. To describe patients younger than 18 years who were infected with ZIKV and were enrolled in the Sentinel Enhanced Dengue and Acute Febrile Illness Surveillance System (SEDSS). Children infected with ZIKV with 7 or fewer days of fever or emancipated minors aged 14 to 17 years with a generalized maculopapular rash, arthritis or arthralgia, or nonpurulent conjunctivitis were eligible for enrollment on or before December 31, 2016, in Puerto Rico. Patients were evaluated using ZIKV polymerase chain reaction testing at 7 or fewer days after the onset of symptoms. Available ZIKV polymerase chain reaction-positive specimens were evaluated to determine viral loads. Confirmed polymerase chain reaction-positive ZIKV infection. Clinical characteristics and viral loads of symptomatic children with confirmed ZIKV infection. Of 7191 children enrolled in SEDSS on or before December 31, 2016, only those with confirmed ZIKV infection (351 participants) were included in this study. Participants who had confirmed ZIKV infection included 25 infants (7.1%), 69 children (19.7%) aged 1 to 4 years, 95 (27.1%) aged 5 to 9 years, and 162 (46.1%) aged 10 to 17 years. Among these, 260 patients (74.1%) presented for evaluation of ZIKV infection at fewer than 3 days after the onset of symptoms, 340 (96.9%) were discharged to home after evaluation, and 349 (99.4%) had fever, 280 (79.8%) had a rash, 243 (69.2%) had facial or neck erythema, 234 (66.7%) had fatigue, 223 (63.5%) had headache, 212 (60.4%) had chills, 206 (58.7%) had pruritus, and 204 (58.1%) had conjunctival hyperemia. Of 480 specimens collected (317 serum and 163 urine specimens) from 349 children, the median number of days after the onset of symptoms was lower for children who had serum specimens (1 day [interquartile range (IQR), 1-2 days]) than for children who had urine specimens (2 [1-3] days) (P < .001). Of 131 children who had both serum and urine specimens collected on the same day, the median viral load was higher in serum than in urine (median [IQR], 23 098 [8784-88 242] copies/mL for serum vs 9966 [2815-52 774] copies/mL for urine; P = .02). When a single serum sample from each of 317 patients was analyzed, there were no statistically significant differences in median viral loads according to age, sex, or disposition. However, the median serum viral load varied significantly according to the number of days after the onset of symptoms (0 days, 106 778 [IQR, 9772-1 571 718] copies/mL; 1 day, 46 299 [10 663-255 030] copies/mL; 2 days, 20 678 [8763-42 458] copies/mL; and ≥3 days, 15 901 [5135-49 248] copies/mL; P = .001). This study represents the largest study to date of ZIKV infection in the pediatric population. Most children infected with ZIKV had fever, rash, and conjunctival hyperemia. The children usually presented for evaluation at fewer than 3 days after the onset of symptoms. Viral loads for ZIKV were higher in serum vs urine specimens. Median viral loads in serum specimens differed significantly according to the number of days after the onset of symptoms.
Isolation of Infective Zika Virus from Urine and Saliva of Patients in Brazil
da Silva, Kely A. B.; de Castro, Marcia G.; Gerber, Alexandra L.; de Almeida, Luiz G. P.; Lourenço-de-Oliveira, Ricardo; Vasconcelos, Ana Tereza R.
2016-01-01
Background Zika virus (ZIKV) is an emergent threat provoking a worldwide explosive outbreak. Since January 2015, 41 countries reported autochthonous cases. In Brazil, an increase in Guillain-Barré syndrome and microcephaly cases was linked to ZIKV infections. A recent report describing low experimental transmission efficiency of its main putative vector, Ae. aegypti, in conjunction with apparent sexual transmission notifications, prompted the investigation of other potential sources of viral dissemination. Urine and saliva have been previously established as useful tools in ZIKV diagnosis. Here, we described the presence and isolation of infectious ZIKV particles from saliva and urine of acute phase patients in the Rio de Janeiro state, Brazil. Methodology/Principal Findings Nine urine and five saliva samples from nine patients from Rio de Janeiro presenting rash and other typical Zika acute phase symptoms were inoculated in Vero cell culture and submitted to specific ZIKV RNA detection and quantification through, respectively, NAT-Zika, RT-PCR and RT-qPCR. Two ZIKV isolates were achieved, one from urine and one from saliva specimens. ZIKV nucleic acid was identified by all methods in four patients. Whenever both urine and saliva samples were available from the same patient, urine viral loads were higher, corroborating the general sense that it is a better source for ZIKV molecular diagnostic. In spite of this, from the two isolated strains, each from one patient, only one derived from urine, suggesting that other factors, like the acidic nature of this fluid, might interfere with virion infectivity. The complete genome of both ZIKV isolates was obtained. Phylogenetic analysis revealed similarity with strains previously isolated during the South America outbreak. Conclusions/Significance The detection of infectious ZIKV particles in urine and saliva of patients during the acute phase may represent a critical factor in the spread of virus. The epidemiological relevance of this finding, regarding the contribution of alternative non-vectorial ZIKV transmission routes, needs further investigation. PMID:27341420
Ercan, Müjgan; Akbulut, Emiş Deniz; Abuşoğlu, Sedat; Yılmaz, Fatma Meriç; Oğuz, Esra Fırat; Topçuoğlu, Canan; Öztekin, Volkan; Boğdaycıoğlu, Nihal
2015-09-01
Laboratories determine the most appropriate approach for the collection and transport of urine specimens. We investigated the effect of a chlorhexidine-based preservative tube on sample stability, compared the results of refrigerated polystyrene tubes with no additives, and investigated the effect of temperature on the performance of preservative tubes. Fresh urine specimen (n=48) aliquots in BD Vacutainer® Plus Urinalysis Preservative Tubes and polystyrene tubes were analyzed on an Iris Diagnostics iQ200. Samples in polystyrene tubes were refrigerated for 4 and 8h. Four aliquots in preservative tubes were kept at room temperature for 4, 8, 24, and 72h, while two aliquots were kept on ice for 4 and 8h. There was good agreement for all chemistry and microscopy parameters with the exceptions of white blood cells (WBCs) at 24 and 72h and red blood cells (RBCs) at 72h. Preservative tubes on ice showed a significant decrease in concordance of WBCs and calcium oxalate (CaOx) parameters compared with the results at room temperature. Results of refrigerated polystyrene tubes showed good agreement with the exceptions of WBC clumps and amorphous crystal at 8h. A chlorhexidine-containing preservative tube seems advantageous for urine sample transport from outside healthcare services. A preservative tube offers comparable results with urine samples kept in a refrigerator for 4-8h for the majority of parameters. Keeping samples at room temperature is recommended when preservative tubes are used because ice produces a negative effect on WBCs and CaOx. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Analysis of cannabis in oral fluid specimens by GC-MS with automatic SPE.
Choi, Hyeyoung; Baeck, Seungkyung; Kim, Eunmi; Lee, Sooyeun; Jang, Moonhee; Lee, Juseon; Choi, Hwakyung; Chung, Heesun
2009-12-01
Methamphetamine (MA) is the most commonly abused drug in Korea, followed by cannabis. Traditionally, MA analysis is carried out on both urine and hair samples and cannabis analysis in urine samples only. Despite the fact that oral fluid has become increasingly popular as an alternative specimen in the field of driving under the influence of drugs (DUID) and work place drug testing, its application has not been expanded to drug analysis in Korea. Oral fluid is easy to collect and handle and can provide an indication of recent drug abuse. In this study, we present an analytical method using GC-MS to determine tetrahydrocannabinol (THC) and its main metabolite 11-nor-delta9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) in oral fluid. The validated method was applied to oral fluid samples collected from drug abuse suspects and the results were compared with those in urine. The stability of THC and THC-COOH in oral fluid stored in different containers was also investigated. Oral fluid specimens from 12 drug abuse suspects, submitted by the police, were collected by direct expectoration. The samples were screened with microplate ELISA. For confirmation they were extracted using automated SPE with mixed-mode cation exchange cartridge, derivatized and analyzed by GC-MS using selective ion monitoring (SIM). The concentrations ofTHC and THC-COOH in oral fluid showed a large variation and the results from oral fluid and urine samples from cannabis abusers did not show any correlation. Thus, detailed information about time interval between drug use and sample collection is needed to interpret the oral fluid results properly. In addition, further investigation about the detection time window ofTHC and THC-COOH in oral fluid is required to substitute oral fluid for urine in drug testing.
Cost and Efficacy Assessment of an Alternative Medication Compliance Urine Drug Testing Strategy.
Doyle, Kelly; Strathmann, Frederick G
2017-02-01
This study investigates the frequency at which quantitative results provide additional clinical benefit compared to qualitative results alone. A comparison between alternative urine drug screens and conventional screens including the assessment of cost-to-payer differences, accuracy of prescription compliance or polypharmacy/substance abuse was also included. In a reference laboratory evaluation of urine specimens from across the United States, 213 urine specimens with provided prescription medication information (302 prescriptions) were analyzed by two testing algorithms: 1) conventional immunoassay screen with subsequent reflexive testing of positive results by quantitative mass spectrometry; and 2) a combined immunoassay/qualitative mass-spectrometry screen that substantially reduced the need for subsequent testing. The qualitative screen was superior to immunoassay with reflex to mass spectrometry in confirming compliance per prescription (226/302 vs 205/302), and identifying non-prescription abuse (97 vs 71). Pharmaceutical impurities and inconsistent drug metabolite patterns were detected in only 3.8% of specimens, suggesting that quantitative results have limited benefit. The percentage difference between the conventional testing algorithm and the alternative screen was projected to be 55%, and a 2-year evaluation of test utilization as a measure of test order volume follows an exponential trend for alternative screen test orders over conventional immunoassay screens that require subsequent confirmation testing. Alternative, qualitative urine drug screens provide a less expensive, faster, and more comprehensive evaluation of patient medication compliance and drug abuse. The vast majority of results were interpretable with qualitative results alone indicating a reduced need to automatically reflex to quantitation or provide quantitation for the majority of patients. This strategy highlights a successful approach using an alternative strategy for both the laboratory and physician to align clinical needs while being mindful of costs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Watts, V.W.; Caplan, Y.H.
The Coat-A-Count solid phase {sup 125}I Fentanyl Radioimmunoassay was evaluated with respect to linearity and precision using equine urine fortified with fentanyl and then compared with a gas chromatographic/mass spectrometric method for quantification of fentanyl in urine. The RIA assay was found to be linear over the urine fentanyl concentration range of 0.25 to 7.5 ng/mL and precise with coefficients of variation (CV) ranging from 9.6 to 19.3%. The RIA calibrators, ranging in fentanyl concentrations from 0.25 to 7.5 ng/mL, and controls, at mean fentanyl concentrations of 0.46 and 1.32 ng/mL, were compared by both the RIA and GC/MS methods.more » The cross-reactivity with the {sup 125}I RIA test was determined for the fentanyl metabolites, norfentanyl and hydroxyfentanyl, and found to be 5% and 35%, respectively. The illicit fentanyl analogs were found to show significant cross-reactivity, ranging from 20 to 100%. The {sup 125}I RIA was compared to GC/MS quantifications of fentanyl in 35 positive and 20 negative case urine specimens.« less
Archary, Moherndran; Adler, Hugh; La Russa, Philip; Mahabeer, Prasha; Bobat, Raziya A
2017-02-01
Bacterial infections in HIV-infected children admitted with severe acute malnutrition (SAM) contribute to higher mortality and poorer outcomes. This study describes the spectrum of bacterial infections in antiretroviral treatment (ART)-naïve, HIV-infected children admitted with SAM. Between July 2012 and February 2015, 82 children were prospectively enrolled in the King Edward VIII Hospital, Durban. Specimens obtained on and during admission for microbiological evaluation, if clinically indicated, included blood, urine (obtained by catheterisation or suprapubic aspiration), induced sputum and cerebrospinal fluid. All positive bacterial cultures between admission and 30 days after enrollment were documented and characterised into samples taken either within 2 days of admission (infections on admission) or within 2-30 days of admission (hospital-acquired infections, HAIs). On admission, 67% of patients had abnormal white blood cell counts (WBCC) (>12 or <4 × 10 9 /L) and 70% had elevated CRP; 65% were classified as severely immunosuppressed according to the WHO immunological classification. 1 A pathogen was isolated on the admission blood culture in four patients (6%) and in 27% of urine specimens. HAIs were predominately Gram-negative (39/43), and 39.5% were extended-spectrum β-lactamase-positive. Mortality was not significantly associated with isolation of a bacterial pathogen. Routine pre-hospital administration of antibiotics as per the Integrated Management of Childhood Illness (IMCI) guidelines may be responsible for the low rates of positive admission blood cultures. HAIs with drug-resistant Gram-negative organisms are an area of concern and strategies to improve the prevention of HAIs in this vulnerable population are urgently needed.
40 CFR 792.195 - Retention of records.
Code of Federal Regulations, 2011 CFR
2011-07-01
... mutagenicity tests, specimens of soil, water, and plants, and wet specimens of blood, urine, feces, biological... 40 Protection of Environment 32 2011-07-01 2011-07-01 false Retention of records. 792.195 Section... ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Records and Reports § 792.195 Retention of records...
40 CFR 792.195 - Retention of records.
Code of Federal Regulations, 2014 CFR
2014-07-01
... mutagenicity tests, specimens of soil, water, and plants, and wet specimens of blood, urine, feces, biological... 40 Protection of Environment 32 2014-07-01 2014-07-01 false Retention of records. 792.195 Section... ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Records and Reports § 792.195 Retention of records...
40 CFR 792.195 - Retention of records.
Code of Federal Regulations, 2012 CFR
2012-07-01
... mutagenicity tests, specimens of soil, water, and plants, and wet specimens of blood, urine, feces, biological... 40 Protection of Environment 33 2012-07-01 2012-07-01 false Retention of records. 792.195 Section... ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Records and Reports § 792.195 Retention of records...
40 CFR 792.195 - Retention of records.
Code of Federal Regulations, 2013 CFR
2013-07-01
... mutagenicity tests, specimens of soil, water, and plants, and wet specimens of blood, urine, feces, biological... 40 Protection of Environment 33 2013-07-01 2013-07-01 false Retention of records. 792.195 Section... ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Records and Reports § 792.195 Retention of records...
40 CFR 792.190 - Storage and retrieval of records and data.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 31 2010-07-01 2010-07-01 true Storage and retrieval of records and data. 792.190 Section 792.190 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... mutagenicity tests, specimens of soil, water, and plants, and wet specimens of blood, urine, feces, and...
49 CFR 40.83 - How do laboratories process incoming specimens?
Code of Federal Regulations, 2012 CFR
2012-10-01
... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.83 How do laboratories... copies of the CCF or any copies of the alcohol testing form. (b) You must comply with applicable provisions of the HHS Guidelines concerning accessioning and processing urine drug specimens. (c) You must...
49 CFR 40.83 - How do laboratories process incoming specimens?
Code of Federal Regulations, 2014 CFR
2014-10-01
... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.83 How do laboratories... copies of the CCF or any copies of the alcohol testing form. (b) You must comply with applicable provisions of the HHS Guidelines concerning accessioning and processing urine drug specimens. (c) You must...
49 CFR 40.83 - How do laboratories process incoming specimens?
Code of Federal Regulations, 2013 CFR
2013-10-01
... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.83 How do laboratories... copies of the CCF or any copies of the alcohol testing form. (b) You must comply with applicable provisions of the HHS Guidelines concerning accessioning and processing urine drug specimens. (c) You must...
49 CFR 40.83 - How do laboratories process incoming specimens?
Code of Federal Regulations, 2011 CFR
2011-10-01
... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.83 How do laboratories... copies of the CCF or any copies of the alcohol testing form. (b) You must comply with applicable provisions of the HHS Guidelines concerning accessioning and processing urine drug specimens. (c) You must...
49 CFR 40.83 - How do laboratories process incoming specimens?
Code of Federal Regulations, 2010 CFR
2010-10-01
... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.83 How do laboratories... copies of the CCF or any copies of the alcohol testing form. (b) You must comply with applicable provisions of the HHS Guidelines concerning accessioning and processing urine drug specimens. (c) You must...
Schoeller, D A; Colligan, A S; Shriver, T; Avak, H; Bartok-Olson, C
2000-09-01
The doubly labeled water method is commonly used to measure total energy expenditure in free-living subjects. The method, however, requires accurate and precise deuterium abundance determinations, which can be laborious. The aim of this study was to evaluate a fully automated, high-throughput, chromium reduction technique for the measurement of deuterium abundances in physiological fluids. The chromium technique was compared with an off-line zinc bomb reduction technique and also subjected to test-retest analysis. Analysis of international water standards demonstrated that the chromium technique was accurate and had a within-day precision of <1 per thousand. Addition of organic matter to water samples demonstrated that the technique was sensitive to interference at levels between 2 and 5 g l(-1). Physiological samples could be analyzed without this interference, plasma by 10000 Da exclusion filtration, saliva by sedimentation and urine by decolorizing with carbon black. Chromium reduction of urine specimens from doubly labeled water studies indicated no bias relative to zinc reduction with a mean difference in calculated energy expenditure of -0.2 +/- 3.9%. Blinded reanalysis of urine specimens from a second doubly labeled water study demonstrated a test-retest coefficient of variation of 4%. The chromium reduction method was found to be a rapid, accurate and precise method for the analysis of urine specimens from doubly labeled water. Copyright 2000 John Wiley & Sons, Ltd.
Measles virus genotypes circulating in India, 2011-2015.
Vaidya, Sunil R; Chowdhury, Deepika T
2017-05-01
The Government of India is accepted to participate in the measles elimination and rubella control goal 2020, hence genetic characterization of measles viruses (MeV) becomes essential. At National Reference Laboratory (National Institute of Virology, Pune), the throat swabs/urine specimens (n = 380) or PCR products (n = 219) obtained from the suspected measles cases were referred for the molecular testing and subsequently, MeV nucleoprotein (N) gene sequencing/genotyping. In addition, 2,449 suspected measles cases, mainly from the Maharashtra state were referred for the laboratory diagnosis. A detailed study was performed on N gene sequences obtained during last two decades. Indian MeV sequences obtained during 2011-2015 were compared with 1996-2010 sequences and genetic divergence was studied. Circulation of measles genotypes B3 (n = 3), D4 (n = 49), and D8 (n = 351) strains were observed in 19 States and three Union Territories of India. In addition, 64 measles viruses were isolated from 253 throat swab or urine specimens obtained from the suspected measles cases. During 2011-2015, 67.9% (1,663/2,449) suspected measles cases were laboratory confirmed. Molecular studies showed circulation of measles genotype B3 in India along with prominently circulating genotypes D4 and D8 except D7 strains. The genetic diversion within Indian B3, D4, and D8 genotypes was 0.3%, 1.1%, and 2.1%, respectively. The genetic divergence of Indian B3, D4, and D8 measles strains with the WHO reference sequences was 2.5%, 2.6%, and 1.8%, respectively. It is crucial data for national immunization program. More measles/rubella genotyping studies are necessary to track transmission and to support measles elimination and rubella control. J. Med. Virol. 89:753-758, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Detection of iso-α-acids to confirm beer consumption in postmortem specimens.
Rodda, Luke N; Gerostamoulos, Dimitri; Drummer, Olaf H
2015-01-01
Iso-α-acids (IAAs) can be used as markers for the consumption of beer. Postmortem specimens from a range of coronial cases were analyzed for IAAs in order to determine the prevalence of beer consumption and any correlation to blood alcohol concentrations (BAC). A total of 130 cases were included in this study including those where beer was mentioned in the case circumstances, cases where beer was not mentioned specifically but alcohol was detected, and cases where neither beer was mentioned nor a positive BAC was present. Available blood, serum, vitreous humour and urine specimens were analyzed. Of the 50 cases where beer was mentioned, 86% had one or more IAAs detected. In cases that only had a positive BAC (n = 60), 57% of these cases also showed the presence of these beer markers. IAAs were detected in specimens obtained from traumatized, burnt, and decomposed cases with a mention of beer consumption or where BAC was positive in blood. No IAAs were detected in cases where BAC was negative. There was little or no correlation between blood IAA concentrations and BAC. This study demonstrates the possible detection of IAAs as a marker for beer consumption. Copyright © 2014 John Wiley & Sons, Ltd.
Southern, Timothy R.; Racsa, Lori D.; Albariño, César G.; Fey, Paul D.; Hinrichs, Steven H.; Murphy, Caitlin N.; Herrera, Vicki L.; Sambol, Anthony R.; Hill, Charles E.; Ryan, Emily L.; Kraft, Colleen S.; Campbell, Shelley; Sealy, Tara K.; Schuh, Amy; Ritchie, James C.; Lyon, G. Marshall; Mehta, Aneesh K.; Varkey, Jay B.; Ribner, Bruce S.; Brantly, Kent P.; Ströher, Ute; Iwen, Peter C.
2015-01-01
Rapid, reliable, and easy-to-use diagnostic assays for detection of Zaire ebolavirus (ZEBOV) are urgently needed. The goal of this study was to examine the agreement among emergency use authorization (EUA) tests for the detection of ZEBOV nucleic acids, including the BioFire FilmArray BioThreat (BT) panel, the FilmArray BT-E panel, and the NP2 and VP40 quantitative real-time reverse transcriptase (qRT) PCR assays from the Centers for Disease Control and Prevention (CDC). Specimens used in this study included whole blood spiked with inactivated ZEBOV at known titers and whole-blood, plasma, and urine clinical specimens collected from persons diagnosed with Ebola virus disease (EVD). The agreement for FilmArray and qRT-PCR results using contrived whole-blood specimens was 100% (6/6 specimens) for each ZEBOV dilution from 4 × 107 to 4 × 102 50% tissue culture infective dose (TCID50)/ml, as well as the no-virus negative-control sample. The limit of detection for FilmArray and qRT-PCR assays with inactivated ZEBOV, based on duplicate positive results, was determined to be 4 × 102 TCID50/ml. Rates of agreement between FilmArray and qRT-PCR results for clinical specimens from patients with EVD were 85% (23/27 specimens) for whole-blood specimens, 90% (18/20 specimens) for whole-blood specimens tested by FilmArray testing and matched plasma specimens tested by qRT-PCR testing, and 85% (11/13 specimens) for urine specimens. Among 60 specimens, eight discordant results were noted, with ZEBOV nucleic acids being detected only by FilmArray testing in four specimens and only by qRT-PCR testing in the remaining four specimens. These findings demonstrate that the rapid and easy-to-use FilmArray panels are effective tests for evaluating patients with EVD. PMID:26157148
Tao, Lin; Chen, Mei; Collins, Erin; Lu, Chensheng
2013-02-01
Pyrethroid insecticides are applied in the residential environment, as well as in agricultural crops, for insect control purpose. We developed and validated an accurate, sensitive, and reproducible analytical method to simultaneously detect seven pyrethroid metabolites, namely, 3-(2,2-dichlorovinyl)-2,2-dimethyl-(1-cyclopropane) carboxylic acid, 3-(2,2-dibromovinyl)-2,2-dimethyl-(1-cyclopropane) carboxylic acid, 3-phenoxybenzoic acid, 4-fluoro-3-phenoxybenzoic acid, 2-methyl-3-phenylbenzoic acid, 4-chloro-α-isoproply benzeneacetic acid, and 3-(2-chloro-3,3,3-trifluoroprop-1-enyl)-2,2-dimethylcyclopropanecarboxylic acid, in human urine. This method employs deconjugation with enzyme, SPE using Agilent C18 cartridges on a RapidTrace SPE workstation, derivatization using hexafluoro isopropanol and N,N'-diisopropylcarbodiimide, and compounds separation and identification on GC-MS. The detection limits of seven metabolites were 0.02-0.08 ng/mL in urine. The recoveries of seven metabolites were 81-104%, 85-99%, and 83-99% in urine specimens fortified at 0.1, 0.4, and 3.2 ng/mL concentrations, respectively. The overall coefficient of variation was 4.3-10.8% in two quality control specimens which were repeatedly measured during a period of 2 months. This method was applied to urine samples collected from children living in Boston, MA. The median concentrations of six detected pyrethroid metabolites ranged from 0.06 to 0.86 ng/mL in urine. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Garcia, Robert; Spitzer, Eric D
2017-10-01
Published literature indicates that the unjustified ordering or improper collection of urine for urinalysis or culture from either catheterized patients or those without indwelling devices, or misinterpretation of positive results, often leads to adverse health care events, including increased financial burdens, overreporting of mandated catheter-associated urinary tract infection events, overtreatment of patients with antimicrobial agents, selection of multidrug-resistant organisms, and Clostridium difficile infection. Moreover, national guidelines that provide evidence-based direction on core processes that form the basis for subsequent clinical therapy decisions or surveillance interpretations; that is, the appropriate ordering and collection of urine for laboratory testing and the treatment of patients with symptomatic urinary tract infection, are not widely known or lack adherence. This article provides published evidence on the influence of inappropriate ordering of urine specimens and subsequent treatment of asymptomatic bacteriuria and associated adverse effects; reviews research on bacterial contamination and preservation; and delineates best practices in the collection, handling, and testing of urine specimens for culture or for biochemical analysis in both catheterized and noncatheterized patients. The goal is to provide infection preventionists (IPs) with a cohesive evidence-based framework that will assist them in facilitating the implementation of a urine culture management program that reduces patient harms, enhances the accuracy of catheter-associated urinary tract infection surveillance, improves antibiotic stewardship, and reduces costs. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Komatsu, Haruki; Inui, Ayano; Sogo, Tsuyoshi; Tateno, Akihiko; Shimokawa, Reiko; Fujisawa, Tomoo
2012-08-15
Body fluids such as saliva, urine, sweat, and tears from hepatitis B virus (HBV) carriers are potential sources of HBV transmission. Thirty-nine children and 8 adults who were chronically infected with HBV were enrolled. Real-time polymerase chain reaction was used for the quantification of HBV DNA. HBV DNA was detected in 73.7% of urine samples (14 of 19), 86.8% of saliva samples (33 of 38), 100% of tear samples (11 of 11), and 100% of sweat samples (9 of 9). Mean HBV DNA levels (±SD) in urine, saliva, tears, and sweat were 4.3 ± 1.1 log copies/mL, 5.9 ± 1.2 log copies/mL, 6.2 ± 0.7 log copies/mL, and 5.2 ± 0.6 log copies/mL, respectively. A statistically significant correlation was observed between the HBV DNA level in serum specimens and HBV DNA levels in saliva and tear specimens (r = 0.88; P < .001). Tear specimens from a child were injected intravenously into 2 human hepatocyte-transplanted chimeric mice. One week after inoculation, both chimeric mice had serum positive for HBV DNA. The levels of HBV DNA in tear specimens from young children were high. Tears were confirmed to be infectious, using chimeric mice. Strict precautions should be taken against direct contact with body fluids from HBV carriers with high-level viremia.
Improved diagnostics of chronic inflammatory prostatitis.
Kulchavenya, E; Azizoff, A; Brizhatyuk, E; Khomyakov, V; Kholtobin, D; Breusoff, A; Naber, K G
2012-12-01
Prostatitis is a prevalent condition that encompasses a large array of clinical symptoms with significant impacts on men's life. The diagnosis and treatment of this disorder presents numerous challenges for urologists, most notably, a lack of specific and effective diagnostic methods. To improve the diagnostics the comparison of classic 4-glass test Meares and Stamey, 2-glass tests and 3-glass test was conducted in 177 men suspicious for chronic prostatitis. Four-glass test is uncomfortable both for patients and doctors, and leads to contamination of urine with prostatic secretion. Two-glass test is insufficiently effective too. Three-glass test (three urine specimens obtained from one continuous micturition stream) gives more adequate results and may be used for screening. Three-glass test as screening test with the option of an additional EPS investigation in those patients the final diagnosis of chronic prostatitis has to be confirmed is more convenient for patients and doctors than the standard M&S 4-glass test and "false-positive" (contaminated with EPS) midstream urine results are avoided thus improving discrimination of urethritis, cystitis and prostatitis. Therefore, we recommend the KE 3-glass test as a new standard for screening patients with signs and symptoms of chronic inflammatory prostatitis.
Comparative Evaluation of Three Nucleic Acid-Based Assays for BK Virus Quantification
Descamps, Veronique; Martin, Elodie; Morel, Virginie; François, Catherine; Helle, François; Duverlie, Gilles; Castelain, Sandrine
2015-01-01
With the growing importance of BK virus (BKV), effective and efficient screening for BKV replication in plasma and urine samples is very important for monitoring renal transplant and hematopoietic stem cell transplant recipients, who are at increased risk of BKV-associated diseases. However, recent assays proposed by many manufacturers have not been tested, and the available tests have not been standardized. The aim of the present study was to evaluate and compare the performances of three commercially available kits, R-gene, GeneProof, and RealStar, on plasma and urine specimens from patients infected with various genotypes and to determine the correlations with the results from a reference laboratory. A qualitatively excellent global agreement (96.8%) was obtained. RealStar PCR tended to give a higher sensitivity, especially for subtype Ib1 samples. Comparison of 30 plasma samples and 53 urine samples showed a good agreement between the three assays, with Spearman's Rho correlation coefficient values falling between 0.92 and 0.98 (P < 0.001). Moreover, a perfect correlation was obtained for comparison of the assay performances with the AcroMetrix BKV panel (P < 0.001 for all comparisons). According to Bland-Altman analysis, more than 95% (240/249 comparisons) of sample comparisons were situated in the range of the mean ± 2 standard deviations (SD). The greatest variability between assays was observed for 10.2% of subtype Ib2 samples, with differences of >1 log10 copies/ml. In conclusion, this study demonstrated the reliable and comparable performances of the R-gene, GeneProof, and RealStar real-time PCR systems for quantification of BKV in urine and plasma samples. All three real-time PCR assays are appropriate for screening of BKV replication in patients. PMID:26424842
49 CFR Appendix C to Part 219 - Post-Accident Testing Specimen Collection
Code of Federal Regulations, 2010 CFR
2010-10-01
... employee: two 10 ml grey-stoppered blood tubes and the Control Form. b. Ask the donor to complete STEP 1 on... the urine collection area. To the extent practical, all sources of water in the collection area should... standing water. c. The employee will be provided a private place in which to void. Urination will not be...
Urinary Catheterization in Infants: When It's Knot so Simple.
Sheridan, David C; Burns, Beech; Mickley, Megan
2018-02-01
Pediatric fever is one of the most common presenting complaints to emergency departments (ED). While often due to a viral illness, in young children without a source the most common bacterial infection is pyelonephritis. For this reason, when no focal source can be identified a urinary specimen is recommended. In young children who are unable to urinate on demand, a straight catheter is required to obtain a sterile specimen. This is generally a benign procedure and is performed frequently in EDs. We report a case of a young girl who underwent straight bladder catheterization and was subsequently found to have a retained catheter that had become knotted in the bladder. This case report highlights a rare complication of this common procedure and describes the technique required to remove the catheter. An understanding of these issues may avoid the need for transfer to a pediatric facility or for subspecialty consultation.
Bezuidenhout, Karla; Rensburg, Megan A; Hudson, Careen L; Essack, Younus; Davids, M Razeen
2016-07-01
Many clinical laboratories require that specimens for serum and urine osmolality determination be processed within 3 h of sampling or need to arrive at the laboratory on ice. This protocol is based on the World Health Organization report on sample storage and stability, but the recommendation lacks good supporting data. We studied the effect of storage temperature and time on osmolality measurements. Blood and urine samples were obtained from 16 patients and 25 healthy volunteers. Baseline serum, plasma and urine osmolality measurements were performed within 30 min. Measurements were then made at 3, 6, 12, 24 and 36 h on samples stored at 4-8℃ and room temperature. We compared baseline values with subsequent measurements and used difference plots to illustrate changes in osmolality. At 4-8℃, serum and plasma osmolality were stable for up to 36 h. At room temperature, serum and plasma osmolality were very stable for up to 12 h. At 24 and 36 h, changes from baseline osmolality were statistically significant and exceeded the total allowable error of 1.5% but not the reference change value of 4.1%. Urine osmolality was extremely stable at room temperature with a mean change of less than 1 mosmol/kg at 36 h. Serum and plasma samples can be stored at room temperature for up to 36 h before measuring osmolality. Cooling samples to 4-8℃ may be useful when delays in measurement beyond 12 h are anticipated. Urine osmolality is extremely stable for up to 36 h at room temperature. © The Author(s) 2015.
Price, Jameca Renee; Guran, Larissa; Lim, Jeong Youn; Megli, Christina J; Clark, Amanda L; Edwards, Sharon Renee; Denman, Mary Anna; Gregory, W Thomas
Acute uncomplicated urinary tract infection (UTI) in women is often treated based on symptoms alone. Urinary tract infection symptoms are highly sensitive but lack specificity and result in overuse of antibiotics. We sought to determine if urine neutrophil gelatinase-associated lipocalin (uNGAL) levels in urine can accurately discriminate between UTI and healthy women. We recruited adult women aged 18 to 85 years presenting in the ambulatory setting from November 2014 to January 2016. Cases were defined as women with Centers for Disease Control and Prevention-defined UTI symptoms and a positive urine culture of more than 10 organisms/mL on a midstream clean-catch specimen. Women without UTI symptoms were matched by age and menopausal status as control subjects. Exclusion criteria were no UTIs within 8 weeks, urinary tract anomalies, renal disease, pregnancy, or diabetes. Clean-catch urine samples were obtained for measuring uNGAL, prior to antibiotic treatment of cases. We used Mann-Whitney U test to compare the 2 groups. Receiver operating characteristic curves were plotted to compare the performance of uNGAL to established urinary markers. We enrolled 50 UTI cases and 50 control subjects. Urine NGAL levels were higher in the UTI group than in the control subjects (P < 0.0001). Using a cutoff of 23.9 ng/mL, NGAL achieved 98% sensitivity and 100% specificity. The receiver operating characteristic curve had an area under the curve of 0.97 (95% confidence interval, 0.93-1.00), which was significantly high and showed that uNGAL can identify UTI. Urine NGAL has the potential as a biomarker for diagnosing UTIs in adult women.
Matsushima, K; Nagai, T; Kamiyama, S
1998-01-01
Identification of the optical activity and simultaneous analysis of racemates (+/-) of three hallucinogens, 3,4-methylenedioxy-amphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA), and 3,4-methylenedioxyethylamphetamine (MDEA), and the urinary excretion of their optical isomers in rats was performed by high-performance liquid chromatographic analysis. Analysis of optical enantiomers of three N-alkyl MDA derivatives was performed within 50 min using two different detectors, polarimetry (OR) and ultraviolet spectroscopy (UV). The OR detector proved suitable for identification of the optically active forms, whereas the UV detector was suitable for simultaneous analysis of the enantiomers in urine. After the administration of each of the three N-alkylated derivatives, rat urine specimens were collected over four intervals, 0-4, 4-12, 12-20, and 20-24 h. After the administration of 30 mg/kg of racemic MDA and MDMA, somewhat less of the S(+)-forms of unchanged MDA and MDMA than of the R(-)-forms in each urine specimen were detected, which gave R/S ratios greater than 1.00 (p < 0.01). Conversely, after the administration of 30 mg/kg of racemic MDEA, more of the S(+)-form than the R(-)-form was found in the urine, thus giving R/S ratios less than 1.00 (p < 0.01). The percentage of the dose excreted up to 24 h was approximately 29.4% of the administered dose for MDA [S(+) 13.40% and R(-) 15.98%], 5.8% for MDMA [S(+) 1.96% and R(-) 3.79%], and 7.3% for MDEA [S(+) 3.89% and R(-) 3.43%]. Urinary excretion of optical isomers of N-dealkylated MDA from MDMA and MDEA origin were the opposite of those of the unchanged forms, and their R/S ratios up to 24 h were 0.48 to 0.72 (p < 0.01) and 1.31 to 1.50 (p < 0.01), respectively. The urinary excretion rates up to 24 h were approximately 4.3% for N-dealkylated MDA from MDMA origin [S(+) 2.72% and R(-) 1.63%] and 0.8% for N-dealkylated MDA from MDEA origin [S(+) 0.36% and R(-) 0.47%]. The total percent of unchanged forms and N-dealkylated MDA was approximately 10.1% for MDMA [S(+) 4.68% and R(-) 5.42%] and 8.2% for MDEA [S(+) 4.25% and R(-) 3.91%]. The total R/S ratio of MDMA was found to be 1.95 (p < 0.01), whereas that of MDEA was 0.88 (p < 0.01). The total R/S ratio of MDA was 1.20 (p < 0.01 ), which was comparable with that of MDMA. These three R/S ratios did not conform to the theoretical values for three N-alkyl derivatives used and neither did the R/S ratios of urine specimens collected at the four interval. These results suggested the stereoselective disposition of three N-alkyl MDA analogues in rat. The method would be suitable for the forensic chemistry and toxicology analysis of specimens obtained from hallucinogen abusers.
Spaan, Suzanne; Pronk, Anjoeka; Koch, Holger M; Jusko, Todd A; Jaddoe, Vincent W V; Shaw, Pamela A; Tiemeier, Henning M; Hofman, Albert; Pierik, Frank H; Longnecker, Matthew P
2015-05-01
The widespread use of organophosphate (OP) pesticides has resulted in ubiquitous exposure in humans, primarily through their diet. Exposure to OP pesticides may have adverse health effects, including neurobehavioral deficits in children. The optimal design of new studies requires data on the reliability of urinary measures of exposure. In the present study, urinary concentrations of six dialkyl phosphate (DAP) metabolites, the main urinary metabolites of OP pesticides, were determined in 120 pregnant women participating in the Generation R Study in Rotterdam. Intra-class correlation coefficients (ICCs) across serial urine specimens taken at <18, 18-25, and >25 weeks of pregnancy were determined to assess reliability. Geometric mean total DAP metabolite concentrations were 229 (GSD 2.2), 240 (GSD 2.1), and 224 (GSD 2.2) nmol/g creatinine across the three periods of gestation. Metabolite concentrations from the serial urine specimens in general correlated moderately. The ICCs for the six DAP metabolites ranged from 0.14 to 0.38 (0.30 for total DAPs), indicating weak to moderate reliability. Although the DAP metabolite levels observed in this study are slightly higher and slightly more correlated than in previous studies, the low to moderate reliability indicates a high degree of within-person variability, which presents challenges for designing well-powered epidemiological studies.
Validation of APF as a Urinary Biomarker for Interstitial Cystitis
2016-12-01
using a CKAP4127-360 biosensor with sufficient binding efficiency to detect as-APF in urine with detection limits in the high nM to uM range. Urine...specimens from 14 (47%) of 30 women diagnosed with IC/PBS demonstrated as-APF binding activity to the CKAP4127-360 biosensor compared with 22 (73%) of 30...CKAP4 immobilized biosensor to detect APF (1-24 months) 2) Determine the ability of the SPR-based assay to detect APF in urine from patients with IC (1
[Correlation between load of polyomavirus and hemorrhagic cystitis].
Tong, Chun-Rong; Teng, Zhi-Ping; Liu, Hong-Xing; Cai, Peng; Ma, Si-Kun; Zhen, Cheng-Liang; Zeng, Yi; Lu, Dao-Pei
2007-09-01
To study the correlation between polyoma virus load and hemorrhagic cystitis after allogeneic stem cells transplantation for prevention of hemorrhagic cystitis. Blood and urine specimens were collected from 40 healthy persons, 40 patient with stem cells transplantation and 20 cases complicated with hemorrhagic cystitis for determination of VP1 gene of polyomaviruses BK virus (BKV)/Jamestown Canyon virus (JCV) and simian virus 40 (SV40) by polymerase chain reaction (PCR) and EvaGreen stain fluorescence quantitative assay. In the peripheral blood, all genes of BKV/JCV and SV40 were negative, while BKV gene in urine and blood from healthy persons and patient with stem cells transplantation was 15% (6/40) and 100% (40/40), respectively. The gene of JCV was positive in 10% (4/40) and 12% (5/40), the gene of SV40 was negative. Genes of BKV and JCV was detectable in urine specimens of healthy persons and there was a correlation between the load of polyomavirus and incidence of hemorrhagic cystitis.
Reyes, John Carlo B; Solon, Juan Antonio A; Rivera, Windell L
2014-07-01
A loop-mediated isothermal amplification (LAMP) assay targeting the 2-kbp repeated DNA species-specific sequence was developed for detection of Trichomonas vaginalis, the causative agent of trichomoniasis. The analytical sensitivity and specificity of the LAMP assay were evaluated using pooled genital swab and urine specimens, respectively, spiked with T. vaginalis trophozoites. Genital secretion and urine did not inhibit the detection of the parasite. The sensitivity of the LAMP was 10-1000 times higher than the PCR performed. The detection limit of LAMP was 1 trichomonad for both spiked genital swab and urine specimens. Also, LAMP did not exhibit cross-reactivity with closely-related trichomonads, Trichomonas tenax and Pentatrichomonas hominis, and other enteric and urogenital microorganisms, Entamoeba histolytica, Candida albicans, Escherichia coli, Pseudomonas aeruginosa, and Staphylococcus aureus. This is the first report of a LAMP assay for the detection of T. vaginalis and has prospective application for rapid diagnosis and control of trichomoniasis. Copyright © 2014 Elsevier Inc. All rights reserved.
Bang, Hae In; Jang, Mi Ae; Lee, Yong Wha
2017-11-01
The demand for rapid and broad clinical toxicology screens is on the rise. Recently, a new rapid toxicology screening test, the Triage TOX Drug Screen (Alere Inc., USA), which can simultaneously detect 11 drugs of abuse and therapeutic drugs with an instrument-read cartridge, was developed. In the present study, we evaluated the efficacy of this new on-site immunoassay using 105 urine specimens; the results were compared with those obtained by using ultra-performance liquid chromatography with tandem mass spectrometry (UPLC-TMS). Precision was evaluated according to the CLSI EP12-A2 for analyte concentrations near the cutoff, including C₅₀ and±30% of C₅₀, for each drug using standard materials. The C₅₀ specimens yielded 35-65% positive results and the±30% concentration range of all evaluated drugs encompassed the C₅-C₉₅ interval. The overall percent agreement of the Triage TOX Drug Screen was 92.4-100% compared with UPLC-TMS; however, the Triage TOX Drug Screen results showed some discordant cases including acetaminophen, amphetamine, benzodiazepine, opiates, and tricyclic antidepressants. The overall performance of the Triage TOX Drug Screen assay was comparable to that of UPLC-TMS for screening of drug intoxication in hospitals. This assay could constitute a useful screening method for drugs of abuse and therapeutic drugs in urine. © The Korean Society for Laboratory Medicine.
Passive cannabis smoke exposure and oral fluid testing.
Niedbala, Sam; Kardos, Keith; Salamone, Sal; Fritch, Dean; Bronsgeest, Matth; Cone, Edward J
2004-10-01
Oral fluid testing for Delta(9)-tetrahydrocannabinol (THC) provides a convenient means of detection of recent cannabis usage. In this study, the risk of positive oral fluid tests from passive cannabis smoke exposure was investigated by housing four cannabis-free volunteers in a small, unventilated, and sealed room with an approximate volume of 36 m(3). Five active cannabis smokers were also present in the room, and each smoked a single cannabis cigarette (1.75% THC). Cannabis smoking occurred over the first 20 min of the study session. All subjects remained in the room for approximately 4 h. Oral fluid specimens were collected with the Intercept DOA Oral Specimen Collection Device. Three urine specimens were collected (0, 20, and 245 min). In addition, three air samples were collected for measurement of THC content. All oral fluid specimens were screened by enzyme immunoassay (EIA) for cannabinoids (cutoff concentration = 3 ng/mL) and tested by gas chromatography-tandem mass spectrometry (GC-MS-MS) for THC (LOQ/LOD = 0.75 ng/mL). All urine specimens were screened by EIA for cannabinoids (cutoff concentration = 50 ng/mL) and tested by GC-MS-MS for THCCOOH (LOQ/LOD = 1 ng/mL). Air samples were measured for THC by GC-MS (LOD = 1 ng/L). A total of eight oral fluid specimens (collected 20 to 50 min following initiation of smoking) from the four passive subjects screened and confirmed positive for THC at concentrations ranging from 3.6 to 26.4 ng/mL. Two additional specimens from one passive subject, collected at 50 and 65 min, screened negative but contained THC in concentrations of 4.2 and 1.1 ng/mL, respectively. All subsequent specimens for passive participants tested negative by EIA and GC-MS-MS for the remainder of the 4-h session. In contrast, oral fluid specimens collected from the five cannabis smokers generally screened and confirmed positive for THC throughout the session at concentrations substantially higher than observed for passive subjects. Urine specimens from active cannabis smokers also screened and confirmed positive at conventional cutoff concentrations. A biphasic pattern of decline for THC was observed in oral fluid specimens collected from cannabis smokers, whereas a linear decline was seen for passive subjects suggesting that initial oral fluid contamination is cleared rapidly and is followed by THC sequestration in the oral mucosa. It is concluded that the risk of positive oral fluid tests from passive cannabis smoke inhalation is limited to a period of approximately 30 min following exposure.
Zenilman, J M; Miller, W C; Gaydos, C; Rogers, S M; Turner, C F
2003-04-01
Nucleic acid amplification tests have facilitated field based STD studies and increased screening activities. However, even with highly specific tests, the positive predictive value (PPV) of such tests may be lower than desirable in low prevalence populations. We estimated PPVs for a single LCR test in a population survey in which positive specimens were retested. The Baltimore STD and Behavior Survey (BSBS) was a population based behavioural survey of adults which included collecting urine specimens to assess the prevalence of gonorrhoea and chlamydial infection. Gonorrhoea and chlamydial infection were diagnosed by ligase chain reaction (LCR). Nearly all positive results were retested by LCR. Because of cost considerations, negative results were not confirmed. Predicted curves for the PPV were calculated for a single testing assuming an LCR test sensitivity of 95%, and test specificities in the range 95.0%-99.9%, for disease prevalences between 1% and 10%. Positive specimens were retested to derive empirical estimates of the PPV of a positive result on a single LCR test. 579 participants age 18-35 provided urine specimens. 20 (3.5%) subjects initially tested positive for chlamydial infection, and 39 (6.7%) tested positive for gonococcal infection. If positive results on the repeat LCR are taken as confirmation of a "true" infection, the observed PPV for the first LCR testing was 89.5% for chlamydial infection and 83.3% for gonorrhoea. This is within the range of theoretical PPVs calculated from the assumed sensitivities and specificities of the LCR assays. Empirical performance of a single LCR testing approximated the theoretically predicted PPV in this field study. This result demonstrates the need to take account of the lower PPVs obtained when such tests are used in field studies or clinical screening of low prevalence populations. Repeat testing of specimens, preferably with a different assay (for example, polymerase chain reaction), and disclosure of the non-trivial potential for false positive test results would seem appropriate in all such studies.
Akay, Ali Ferruh; Aflay, Uğur; Gedik, Abdullah; Sahin, Hayrettin; Bircan, Mehmet Kamuran
2007-01-01
We investigated the potential risk factors for lower urinary tract infection and bacterial stent colonization in patients with double-J stents. A total of 195 double-J stents from 190 patients (95 men and 95 women, mean age 40.22 years) were examined. In all patients, prophylactic antimicrobial therapy was administered at the time of stenting. The stents and urine samples were removed aseptically and the proximal and distal tip segments of the stents were obtained. Three culture specimens were obtained from each stent segment and urine sample. Chi-square tests, odds ratio, and relative risk were used for the statistical analysis. Bacterial colonies were found in 24% (47 of 190) of the urine samples, 31% (61 of 195) of the proximal stent segments, and 34% (67 of 195) of the distal stent segments. Of the pathogens identified, Escherichia coli (34 of 47) was the most common. Diabetes mellitus (P < 0.01), chronic renal failure (P < 0.001), and pregnancy (P < 0.01) were found to be risk factors for lower urinary tract infection in patients with stents. An increased stent colonization rate was associated with implantation time, age, and female sex, but these were not statistically significant for lower urinary tract infection Diabetes mellitus, chronic renal failure, and pregnancy are associated with a higher risk of lower urinary tract infection. Therefore, patients in these categories should be monitored carefully for infectious complications.
49 CFR Appendix C to Part 219 - Post-Accident Testing Specimen Collection
Code of Federal Regulations, 2012 CFR
2012-10-01
... the transfer of the blood tubes on the second line of STEP 5 (the chain of custody block). E. Collect... (the chain of custody block). F. Seal the Individual Employee Kit a. The blood and urine specimens have... railroad representatives handling the box shall document chain of custody of the shipping box and shall...
49 CFR Appendix C to Part 219 - Post-Accident Testing Specimen Collection
Code of Federal Regulations, 2013 CFR
2013-10-01
... the transfer of the blood tubes on the second line of STEP 5 (the chain of custody block). E. Collect... (the chain of custody block). F. Seal the Individual Employee Kit a. The blood and urine specimens have... railroad representatives handling the box shall document chain of custody of the shipping box and shall...
49 CFR Appendix C to Part 219 - Post-Accident Testing Specimen Collection
Code of Federal Regulations, 2014 CFR
2014-10-01
... the transfer of the blood tubes on the second line of STEP 5 (the chain of custody block). E. Collect... (the chain of custody block). F. Seal the Individual Employee Kit a. The blood and urine specimens have... railroad representatives handling the box shall document chain of custody of the shipping box and shall...
Prostate Cancer Biospecimen Cohort Study
2016-10-01
goal of the study is development of a Prostate Cancer Biorepository Network (PCBN) resource site with high quality and well-annotated urine , blood...with no coordinating center and each site will be responsible for maintaining/storing their own data/ samples . 15. SUBJECT TERMS Prostate cancer...Biorepository Network (PCBN) resource site with high quality and well-annotated urine , blood, and tissue specimens as part of a multi-institutional Department of
Code of Federal Regulations, 2014 CFR
2014-10-01
... provide a sufficient amount of urine for a pre-employment follow-up or return-to-duty test because of a... providing a sufficient specimen for a pre-employment follow-up or return-to-duty test and the condition... Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Problems in Drug Tests...
Code of Federal Regulations, 2011 CFR
2011-10-01
... provide a sufficient amount of urine for a pre-employment follow-up or return-to-duty test because of a... providing a sufficient specimen for a pre-employment follow-up or return-to-duty test and the condition... Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Problems in Drug Tests...
Code of Federal Regulations, 2013 CFR
2013-10-01
... provide a sufficient amount of urine for a pre-employment follow-up or return-to-duty test because of a... providing a sufficient specimen for a pre-employment follow-up or return-to-duty test and the condition... Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Problems in Drug Tests...
Code of Federal Regulations, 2010 CFR
2010-10-01
... provide a sufficient amount of urine for a pre-employment follow-up or return-to-duty test because of a... providing a sufficient specimen for a pre-employment follow-up or return-to-duty test and the condition... Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Problems in Drug Tests...
Code of Federal Regulations, 2012 CFR
2012-10-01
... provide a sufficient amount of urine for a pre-employment follow-up or return-to-duty test because of a... providing a sufficient specimen for a pre-employment follow-up or return-to-duty test and the condition... Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Problems in Drug Tests...
Chemical Carcinogen-Induced Changes in tRNA Metabolism in Human Cells.
1983-11-30
expression of carcinogenesis is postulated. MATERIALS AND METHODS Nucleosldem In urine were resolved and quantitated using reversed-phase high performance...liquid chromatography 8 following clarification on a boronate colun 5 . Quantitation was relative to the creatinine content in random urine specimens 7...Patients Urinary nucleoside excretion has been quantitated for patients with nasopharyngeal carcinoma (NPC) and leukemia, and the results nLn m l
Antibiotic prescribing practices for catheter urine culture results.
Chiu, Jonathan; Thompson, G William; Austin, Thomas W; Hussain, Zafar; John, Michael; Bombassaro, Anne Marie; Connelly, Sarah E; Elsayed, Sameer
2013-01-01
The literature suggests that positive results of catheter urine cultures frequently lead to unnecessary antimicrobial prescribing, which therefore represents an important target for stewardship. To assess the appropriateness of antibiotic prescribing in response to the results of urine cultures from patients with indwelling urinary catheters. This retrospective study was conducted at a tertiary care centre and involved adults with indwelling urinary catheters from whom urine specimens were obtained for culture. Patients with positive or negative culture results were identified from microbiology laboratory reports. The medical records of consecutive patients were screened to select a sample of 80 inpatients (40 per group). Abstracted patient histories were independently evaluated by an expert panel of 3 infectious diseases consultants blinded to the decisions of prescribers and of fellow panelists. The primary end point was concordance of each patient's treatment decision (with respect to the indication) between the expert panel (based on majority agreement, i.e., at least 2 of the 3 expert panelists) and the prescriber. The secondary end points were unnecessary days of therapy and selected outcomes over a predefined period after urine was obtained for culture. A total of 591 charts were screened to generate the targeted number of patients. Baseline demographic characteristics were comparable for the 2 groups, except antibiotic exposure before urine collection was significantly more frequent for the group with negative culture results. The treatment decision was concordant in 40% (16/40) of the patients with a positive culture result and 85% (34/40) of those with a negative culture result (p < 0.001). The most common reason for discordance was administration of antibiotics when not indicated (23 of 24 patients with a positive result and 5 of 6 patients with a negative result), which accounted for 165 and 32 unnecessary days of therapy per 1000 inpatient-days, respectively (p < 0.001). Adverse effects occurred in 2 of the 23 patients with a positive result who received antibiotics that were not indicated. Appropriateness of antibiotic prescribing, as measured by concordance of decisions between the expert panel and prescribers, was more common among patients with negative urine culture results than among those with positive results. However, there is an opportunity to improve prescribing for both groups through antimicrobial stewardship initiatives. Unnecessary days of therapy and adverse effects were more common in patients with a positive culture result.
Asymptomatic bacteriuria in sickle cell disease: a cross-sectional study
Cumming, Vanessa; Ali, Susanna; Forrester, Terrence; Roye-Green, Karen; Reid, Marvin
2006-01-01
Background It is known that there is significant morbidity associated with urinary tract infection and with renal dysfunction in sickle cell disease (SCD). However, it is not known if there are potential adverse outcomes associated with asymptomatic bacteriuria (ASB) infections in sickle cell disease if left untreated. This study was undertaken to determine the prevalence of ASB, in a cohort of patients with SCD. Methods This is a cross-sectional study of patients in the Jamaican Sickle Cell Cohort. Aseptically collected mid-stream urine (MSU) samples were obtained from 266 patients for urinalysis, culture and sensitivity analysis. Proteinuria was measured by urine dipsticks. Individuals with abnormal urine culture results had repeat urine culture. Serum creatinine was measured and steady state haematology and uric acid concentrations were obtained from clinical records. This was completed at a primary care health clinic dedicated to sickle cell diseases in Kingston, Jamaica. There were 133 males and 133 females in the sample studied. The mean age (mean ± sd) of participants was 26.6 ± 2.5 years. The main outcome measures were the culture of ≥ 105 colony forming units of a urinary tract pathogen per milliliter of urine from a MSU specimen on a single occasion (probable ASB) or on consecutive occasions (confirmed ASB). Results Of the 266 urines collected, 234 were sterile and 29 had significant bacteriuria yielding a prevalence of probable ASB of 10.9% (29/266). Fourteen patients had confirmed ASB (prevalence 5.3%) of which 13 had pyuria. Controlling for genotype, females were 14.7 times more likely to have confirmed ASB compared to males (95%CI 1.8 to 121.0). The number of recorded visits for symptomatic UTI was increased by a factor of 2.5 (95% CI 1.4 to 4.5, p < 0.005) but serum creatinine, uric acid and haematology values were not different in patients with confirmed ASB compared with those with sterile urine. There was no association with history of gram negative sepsis. Conclusion ASB is a significant problem in individuals with SCD and may be the source of pathogens in UTI. However, further research is needed to determine the clinical significance of ASB in SCD. PMID:16539735
Yarbrough, Melanie L; Briden, Kelleigh E; Mitsios, John V; Weindel, Annette L; Terrill, Cindy M; Hunstad, David A; Dietzen, Dennis J
2018-04-19
Indoleamine-2,3-dioxygenase (IDO) catalyzes the first step of tryptophan (Trp) catabolism, yielding kynurenine (Kyn) metabolites. The kynurenine-to-tryptophan (K/T) ratio is used as a surrogate for biological IDO enzyme activity. IDO expression is increased during Escherichia coli urinary tract infection (UTI). Thus, our objective was to develop a method for measurement of Kyn/Trp ratio in human blood and urine and evaluate its use as a biomarker of UTI. A mass spectrometric method was developed to measure Trp and Kyn in serum and urine specimens. The method was applied to clinical urine specimens from symptomatic pediatric patients with laboratory-confirmed UTI or other acute conditions and from healthy controls. The liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was linear to 500 μmol/L for both Trp and Kyn. Imprecision ranged from 5 to 15% for Trp and 6-20% for Kyn. Analytical recoveries of Trp and Kyn ranged from 96 to 119% in serum and 90-97% in urine. No correlation was found between the K/T ratio and circulating IDO mass (r = 0.110) in serum. Urinary Kyn and Trp in the pediatric test cohort demonstrated elevations in the K/T ratio in symptomatic patients with UTI (median 13.08) and without UTI (median 14.38) compared to healthy controls (median 4.93; p < 0.001 for both comparisons). No significant difference in K/T ratio was noted between symptomatic patients with and without UTI (p = 0.84). Measurement of Trp and Kyn by LC-MS/MS is accurate and precise in serum and urine specimens. While urinary K/T ratio is not a specific biomarker for UTI, it may represent a general indicator of a systemic inflammatory process. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Picciolo, G. L.; Tuttle, S. A.; Schrock, C. G.; Deming, J. W.; Barza, M. J.; Wienstein, L.; Chappelle, E. W.
1977-01-01
The development of a rapid method for determining microbial susceptibilities to antibiotics using the firefly luciferase assay for adenosine triphosphate (ATP) is documented. The reduction of bacterial ATP by an antimicrobial agent was determined to be a valid measure of drug effect in most cases. The effect of 12 antibiotics on 8 different bacterial species gave a 94 percent correlation with the standard Kirby-Buer-Agar disc diffusion method. A 93 percent correlation was obtained when the ATP assay method was applied directly to 50 urine specimens from patients with urinary tract infections. Urine samples were centrifuged first to that bacterial pellets could be suspended in broth. No primary isolation or subculturing was required. Mixed cultures in which one species was predominant gave accurate results for the most abundant organism. Since the method is based on an increase in bacterial ATP with time, the presence of leukocytes did not interfere with the interpretation of results. Both the incubation procedure and the ATP assays are compatible with automation.
King, J W; King, L J
1996-01-01
Because of the increase in use of the newer benzodiazepines, we explored the opportunity to develop a gas chromatographic-mass spectrometric (GC-MS) method that encompasses most of the widely prescribed benzodiazepines in use today. The benzodiazepines included in our study are nordiazepam, oxazepam, temazepam, lorazepam, alpha-hydroxyalprazolam, alpha-hydroxytriazolam, desalkylflurazepam, and 2-hydroxyethylflurazepam. Using 1.0 mL of urine as the matrix, we added the enzyme Glusulase and incubated the specimens for 2 h to obtain the free drugs. The hydrolyzed samples were then loaded onto a Toxi-Lab Spec VC MP3 column containing a 15-mg disc. On-disc derivatization was accomplished by adding N-methyl-N-(t-butyldimethylsilyl) trifluroacetamide (MTBSTFA) with 1% TBDMSCI to the disc. The derivatives were then placed in a GC vial and analyzed by GC-MS in the selected ion monitoring mode. These results were then compared to confirmed positives by the traditional acid hydrolysis GC-MS method.
Prostate cancer marker panel with single cell sensitivity in urine.
Nickens, Kristen P; Ali, Amina; Scoggin, Tatiana; Tan, Shyh-Han; Ravindranath, Lakshmi; McLeod, David G; Dobi, Albert; Tacha, David; Sesterhenn, Isabell A; Srivastava, Shiv; Petrovics, Gyorgy
2015-06-15
Over one million men undergo prostate biopsies annually in the United States, a majority of whom due to elevated serum PSA. More than half of the biopsies turn out to be negative for prostate cancer (CaP). The limitations of both the PSA test and the biopsy procedure have led to the development for more precise CaP detection assays in urine (e.g., PCA3, TMPRSS2-ERG) or blood (e.g., PHI, 4K). Here, we describe the development and evaluation of the Urine CaP Marker Panel (UCMP) assay for sensitive and reproducible detection of CaP cells in post-digital rectal examination (post-DRE) urine. The cellular content of the post-DRE urine was captured on a translucent filter membrane, which is placed on Cytoclear slides for direct evaluation by microscopy and immuno-cytochemistry (ICC). Cells captured on the membrane were assayed for PSA and Prostein expression to identify prostate epithelial cells, and for ERG and AMACR to identify prostate tumor cells. Immunostained cells were analyzed for quantitative and qualitative features and correlated with biopsy positive and negative status for malignancy. The assay was optimized for single cell capture sensitivity and downstream evaluations by spiking a known number of cells from established CaP cell lines, LNCaP and VCaP, into pre-cleared control urine. The cells captured from the post-DRE urine of subjects, obtained prior to biopsy procedure, were co-stained for ERG, AMACR (CaP specific), and Prostein or PSA (prostate epithelium specific) rendering a whole cell based analysis and characterization. A feasibility cohort of 63 post-DRE urine specimens was assessed. Comparison of the UCMP results with blinded biopsy results showed an assay sensitivity of 64% (16 of 25) and a specificity of 68.8% (22 of 32) for CaP detection by biopsy. This pilot study assessing a minimally invasive CaP detection assay with single cell sensitivity cell-capture and characterization from the post-DRE urine holds promise for further development of this novel assay platform. Prostate 75: 969-975, 2015. © 2015 The Authors. The Prostate, published by Wiley Periodicals, Inc. © 2015 The Authors. The Prostate, published by Wiley Periodicals, Inc.
Wang, Yinong; Otis, Christopher N; Florence, Roxanne R
2015-01-01
Urine cytology is mainly used to detect urothelial carcinoma (UC), especially for high-grade lesions including urothelial carcinoma in situ. Benign squamous cells are often seen in the urine specimens of women, they are either exfoliated from the trigone area of the bladder, the urethra, or the cervicovaginal region. However, abnormal squamous cells in the urine raise concerns of abnormalities of the urinary tract and cervicovaginal area which range from squamous metaplasia of the urothelium, a cervicovaginal squamous intraepithelial lesion, condyloma acuminatum of the bladder, UC with squamous differentiation, and squamous cell carcinoma. We present here a unique case of atypical squamous cells (ASCs) in the urine subsequently leading to the diagnosis of endometrioid adenocarcinoma of the endometrium with squamous differentiation. The presence of ASCs in voided urine is a rare finding that may indicate an underlying malignancy. Careful evaluation of squamous cells in the urine is an important part of our daily cytopathology practice. © 2014 Wiley Periodicals, Inc.
Webb, Marquitta C; Salandy, Sinead T; Beckford, Safiya E
2016-01-01
To investigate the hydration status pre- and post-training among university athletes using urine color and weight loss as indicators. Participants were 52 university athletes training for campus games in a developing country. Pre- and post-training urine specimens were compared with a standard urine color scale. Paired t tests were used to compare urine color and difference in body mass pre- and post-training. The mean age of the athletes was 22.87 ± 3.21. A statistically significance difference (p < .01) was observed between pre- (4.31 ± 1.75) and post- (5.67 ± 1.45) training urine color values for males. Hydration status and weight post-training were statistically significantly different both at the level of p < .01. The results suggest that there is a link between urine color and body mass difference among the student athletes tested. Exercise increases hypohydration due to fluid losses, and therefore attention should be given to fluid supplementation and individualization of fluid intake for each athlete.
Schier, J G; Hunt, D R; Perala, A; McMartin, K E; Bartels, M J; Lewis, L S; McGeehin, M A; Flanders, W D
2013-12-01
Diethylene glycol (DEG) mass poisoning is a persistent public health problem. Unfortunately, there are no human biological data on DEG and its suspected metabolites in poisoning. If present and associated with poisoning, the evidence for use of traditional therapies such as fomepizole and/or hemodialysis would be much stronger. To characterize DEG and its metabolites in stored serum, urine, and cerebrospinal fluid (CSF) specimens obtained from human DEG poisoning victims enrolled in a 2006 case-control study. In the 2006 study, biological samples from persons enrolled in a case-control study (42 cases with new-onset, unexplained AKI and 140 age-, sex-, and admission date-matched controls without AKI) were collected and shipped to the Centers for Disease Control and Prevention (CDC) in Atlanta for various analyses and were then frozen in storage. For this study, when sufficient volume of the original specimen remained, the following analytes were quantitatively measured in serum, urine, and CSF: DEG, 2-hydroxyethoxyacetic acid (HEAA), diglycolic acid, ethylene glycol, glycolic acid, and oxalic acid. Analytes were measured using low resolution GC/MS, descriptive statistics calculated and case results compared with controls when appropriate. Specimens were de-identified so previously collected demographic, exposure, and health data were not available. The Wilcoxon Rank Sum test (with exact p-values) and bivariable exact logistic regression were used in SAS v9.2 for data analysis. The following samples were analyzed: serum, 20 case, and 20 controls; urine, 11 case and 22 controls; and CSF, 11 samples from 10 cases and no controls. Diglycolic acid was detected in all case serum samples (median, 40.7 mcg/mL; range, 22.6-75.2) and no controls, and in all case urine samples (median, 28.7 mcg/mL; range, 14-118.4) and only five (23%) controls (median, < Lower Limit of Quantitation (LLQ); range, < LLQ-43.3 mcg/mL). Significant differences and associations were identified between case status and the following: 1) serum oxalic acid and serum HEAA (both OR = 14.6; 95% C I = 2.8-100.9); 2) serum diglycolic acid and urine diglycolic acid (both OR > 999; exact p < 0.0001); and 3) urinary glycolic acid (OR = 0.057; 95% C I = 0.001-0.55). Two CSF sample results were excluded and two from the same case were averaged, yielding eight samples from eight cases. Diglycolic acid was detected in seven (88%) of case CSF samples (median, 2.03 mcg/mL; range, < LLQ, 7.47). Significantly elevated HEAA (serum) and diglycolic acid (serum and urine) concentrations were identified among cases, which is consistent with animal data. Low urinary glycolic acid concentrations in cases may have been due to concurrent AKI. Although serum glycolic concentrations among cases may have initially increased, further metabolism to oxalic acid may have occurred thereby explaining the similar glycolic acid concentrations in cases and controls. The increased serum oxalic acid concentration results in cases versus controls are consistent with this hypothesis. Diglycolic acid is associated with human DEG poisoning and may be a biomarker for poisoning. These findings add to animal data suggesting a possible role for traditional antidotal therapies. The detection of HEAA and diglycolic acid in the CSF of cases suggests a possible association with signs and symptoms of DEG-associated neurotoxicity. Further work characterizing the pathophysiology of DEG-associated neurotoxicity and the role of traditional toxic alcohol therapies such as fomepizole and hemodialysis is needed.
Detection of Intracellular Bacterial Communities in Human Urinary Tract Infection
Rosen, David A; Hooton, Thomas M; Stamm, Walter E; Humphrey, Peter A; Hultgren, Scott J
2007-01-01
Background Urinary tract infections (UTIs) are one of the most common bacterial infections and are predominantly caused by uropathogenic Escherichia coli (UPEC). While UTIs are typically considered extracellular infections, it has been recently demonstrated that UPEC bind to, invade, and replicate within the murine bladder urothelium to form intracellular bacterial communities (IBCs). These IBCs dissociate and bacteria flux out of bladder facet cells, some with filamentous morphology, and ultimately establish quiescent intracellular reservoirs that can seed recurrent infection. This IBC pathogenic cycle has not yet been investigated in humans. In this study we sought to determine whether evidence of an IBC pathway could be found in urine specimens from women with acute UTI. Methods and Findings We collected midstream, clean-catch urine specimens from 80 young healthy women with acute uncomplicated cystitis and 20 asymptomatic women with a history of UTI. Investigators were blinded to culture results and clinical history. Samples were analyzed by light microscopy, immunofluorescence, and electron microscopy for evidence of exfoliated IBCs and filamentous bacteria. Evidence of IBCs was found in 14 of 80 (18%) urines from women with UTI. Filamentous bacteria were found in 33 of 80 (41%) urines from women with UTI. None of the 20 urines from the asymptomatic comparative group showed evidence of IBCs or filaments. Filamentous bacteria were present in all 14 of the urines with IBCs compared to 19 (29%) of 66 samples with no evidence of IBCs (p < 0.001). Of 65 urines from patients with E. coli infections, 14 (22%) had evidence of IBCs and 29 (45%) had filamentous bacteria, while none of the gram-positive infections had IBCs or filamentous bacteria. Conclusions The presence of exfoliated IBCs and filamentous bacteria in the urines of women with acute cystitis suggests that the IBC pathogenic pathway characterized in the murine model may occur in humans. The findings support the occurrence of an intracellular bacterial niche in some women with cystitis that may have important implications for UTI recurrence and treatment. PMID:18092884
Kehinde, E O; Al-Maghrebi, M; Anim, J T; Kapila, K; George, S S; Al-Juwaiser, A; Memon, A
2013-01-01
To assess whether epidermal growth factor receptor (EGFR) and survivin immunostaining of tumour cells in urinary cytology and tissue of patients with bladder cancer has a prognostic significance. Prospective study Department of Surgery (Division of Urology), Mubarak Al-Kabeer Teaching Hospital and Faculty of Medicine, Kuwait University, Kuwait Urine cytology smears obtainedpriorto cystoscopy in patients with transitional cell carcinoma (TCC) of the bladder were immunostained for EGFR and survivin. Bladder cancer tissue resected at surgery was also immunostained for EGFR and survivin expression. Tissue expression of EGFR and survivin in TCC of the bladder was compared to their expression in urine cytology and relationship to tumour grade and stage. 178 patients were studied (43 newly diagnosed bladder cancer, 58 with recurrent TCC and 77 in disease remission). Twenty five patients with normal urothelium served as controls. The mean sensitivity of urine cytology, tissue survivin immunohistochemistry (IHC) and tissue EGFR IHC was 30.5%, 62% and 59% respectively. The corresponding mean specificity was 95%, 79% and 38% respectively. For grades 1, 2 and 3 bladder tumors, tissue expression positivity for EGFR was 47.8%, 92.9%, 100% and for tissue survivin it was 27.8%, 18.2% and 33.3% respectively. For grades 1, 2 and 3 bladder tumors, urine expression positivity for EGFR was 35.7%, 40% and 67.7% and for urine survivin it was 8.3%, 42.9% and 33.3% respectively. Positive EGFR immunostaining of urine cytology specimen or tumour tissue increases with histological grade of TCC of the bladder. Survivin expression is less consistent in both urine cytology specimen and tissue samples. EGFR immunostaining may provide a useful tool in the grading of bladder TCC and aid in the selection of patients that may benefit from administration of EGFR inhibitors.
Metabolic studies of transient tyrosinemia in premature infants
NASA Technical Reports Server (NTRS)
Fernbach, S. A.; Summons, R. E.; Pereira, W. E.; Duffield, A. M.
1975-01-01
The recently developed technique of gas chromatography-mass spectrometry supported by computer has considerably improved the analysis of physiologic fluids. This study attempted to demonstrate the value of this system in the investigation of metabolite patterns in urine in two metabolic problems of prematurity, transient tyrosinemia and late metabolic acidosis. Serial 24-hr urine specimens were analyzed in 9 infants. Transient tyrosinemia, characterized by 5- 10-fold increases over basal excretion of tyrosine, p-hydroxyphenyllactate, and p-hydroxyphenylpyruvate in urine, was noted in five of the infants. Late metabolic acidosis was seen in four infants, but bore no relation to transient tyrosinemia.
Glycopatterns of Urinary Protein as New Potential Diagnosis Indicators for Diabetic Nephropathy
Zhu, Hanyu; Liu, Moyan; Zhong, Yaogang; Shu, Jian; Fu, Xinle; Cai, Guangyan; Chen, Xiangmei; Geng, Wenjia; Yang, Xiaoli; Wu, Minghui
2017-01-01
Diabetic nephropathy is a major cause of chronic kidney disease and end-stage kidney disease. However, so little is known about alterations of the glycopatterns in urine with the development of diabetic nephropathy. Presently, we interrogated glycopatterns in urine specimens using a lectin microarray. The results showed that expression levels of Siaα2-6Gal/GalNAc recognized by SNA exhibited significantly increased tendency with the development of diabetic nephropathy; moreover, SNA blotting indicated glycoproteins (90 kDa, 70 kDa, and 40 kDa) in urine may contribute to this alteration. Furthermore, the glycopatterns of (GlcNAc)2–4 recognized by STL exhibited difference between diabetic and nondiabetic nephropathy. The results of urinary protein microarray fabricated by another 48 urine specimens also indicated (GlcNAc)2–4 is a potential indictor to differentiate the patients with diabetic nephropathy from nondiabetic nephropathy. Furtherly, STL blotting showed that the 50 kDa glycoproteins were correlated with this alteration. In conclusion, our data provide pivotal information to monitor the development of diabetic nephropathy and distinguish between diabetic nephropathy and nondiabetic renal disease based on precise alterations of glycopatterns in urinary proteins, but further studies are needed in this regard. PMID:28401167
Zhang, Tianjing; Chang, Xiaoyu; Liu, Wanlu; Li, Xiaoxia; Wang, Faxuan; Huang, Liping; Liao, Sha; Liu, Xiuying; Zhang, Yuhong; Zhao, Yi
2017-12-01
Sodium, potassium, calcium, magnesium, zinc, copper and iron are associated with the sequela of hypertension. The most reliable method for testing those elements is by collecting 24-h urine samples. However, this is cumbersome and collection of spot urine is more convenient in some circumstance. The aim of this study was to compare the concentrations of different elements in 24-h urine and spot urine. Data was collected from a sub-study of China Salt Substitute and Stroke Study. 240 participants were recruited randomly from 12 villages in two counties in Ningxia, China. Both spot and 24-h urine specimens were collected from each patient. Routine urine test was conducted, and concentration of elements was measured using microwave digestion and Inductively Coupled Plasma-Optical Emission Spectrometry. Partial correlation analysis and Spearman correlation analysis were used to investigate the concentration of different elements and the relationship between 24- h urine and spot urine. A partial correlation in sodium, potassium, calcium, magnesium and iron was found between paired 24-h urine and spot urine samples except copper and zinc: 0.430, 0.426, 0.550, 0.221 and 0.191 respectively. Spot urine can replace 24-h urine for estimating some of the elements in hypertensive patients with normal renal function. Copyright © 2017 Elsevier GmbH. All rights reserved.
Walsh, J Michael; Flegel, Ron; Cangianelli, Leo A; Atkins, Randolph; Soderstrom, Carl A; Kerns, Timothy J
2004-09-01
The objectives of this research were to (1) determine the incidence and prevalence of alcohol and other drug use among motor vehicle crash (MVC) victims admitted to a regional Level-I trauma center, and (2) to examine the utility of using a rapid point-of-collection (POC) drug-testing device to identify MVC patients with drug involvement. Blood and urine specimens were routinely collected per clinical protocol for each MVC victim at the time of admission. Blood alcohol concentration (BAC) levels were determined per standard clinical protocol. Clinical urine specimens were routinely split so that a POC drug-testing device for the detection of commonly abused drugs (Marijuana, Cocaine, Amphetamines, Methamphetamines, and Opiates) could be compared to that of the standard hospital laboratory analysis of each urine specimen (which also included Barbiturates and Benzodiazepines). In the six-month period of this study, nearly two-thirds of trauma center admissions were victims of motor vehicle crashes. During this time, blood and urine was collected from 322 MVC victims. Toxicology results indicated that 59.3% of MVC victims tested positive for either commonly abused drugs or alcohol. More patients tested positive for drug use than tested positive for alcohol, with 33.5% testing positive for drug use only, 15.8% testing positive for alcohol use only, and 9.9% testing positive for both drugs and alcohol. Less than half (45.2%) of the substance-abusing patients in this study would have been identified by an alcohol test alone. After alcohol, marijuana and benzodiazepines were the most frequently detected drugs. Point of collection (POC) test results correlated well with laboratory results and provide important information to initiate rapid intervention/treatment for substance use problems among injured patients.
Kavvalakis, Matthaios P; Tzatzarakis, Manolis N; Theodoropoulou, Eleftheria P; Barbounis, Emmanouil G; Tsakalof, Andreas K; Tsatsakis, Aristidis M
2013-11-01
Imidacloprid (IMI) is a relatively new neuro-active neonicotinoid insecticide and nowadays one of the largest selling insecticides worldwide. In the present study a LC–APCI–MS based method was developed and validated for the quantification of imidacloprid and its main metabolite 6-chloronicotinic acid (6- CINA) in urine and hair specimens. The method was tested in biomonitoring of intentionally exposed animals and subsequently applied for biomonitoring of Cretan urban and rural population. The developed analytical method comprises two main steps of analytes isolation from specimen (solid– liquid extraction with methanol for hair, liquid–liquid extraction with methanol for urine) and subsequent instrumental analysis by LC–APCI–MS. The developed method was applied for the monitoring of IMI and 6-ClNA in hair and urine of laboratory animals (rabbits) intentionally fed with insecticide at low or high doses (40 and 80 mg kg(-1) weight d(-1) respectively) for 24 weeks. The analytes were detected in the regularly acquired hair and urine specimens and their found levels were proportional to the feeding dose and time of exposure with the exception of slight decline of IMI levels in high dose fed rabbits after 24 weeks of feeding. This decline can be explained by the induction of IMI metabolizing enzymes by the substrate. After testing on animal models the method was applied for pilot biomonitoring of Crete urban (n = 26) and rural (n = 32) population. Rural but not urban population is exposed to IMI with 21 positive samples (65.6%) and found median concentration 0.03 ng mg(-1). Maximum concentration detected was 27 ng mg(-1)
Detection of bacteriuria and pyuria by URISCREEN a rapid enzymatic screening test.
Pezzlo, M T; Amsterdam, D; Anhalt, J P; Lawrence, T; Stratton, N J; Vetter, E A; Peterson, E M; de la Maza, L M
1992-01-01
A multicenter study was performed to evaluate the ability of the URISCREEN (Analytab Products, Plainview, N.Y.), a 2-min catalase tube test, to detect bacteriuria and pyuria. This test was compared with the Chemstrip LN (BioDynamics, Division of Boehringer Mannheim Diagnostics, Indianapolis, Ind.), a 2-min enzyme dipstick test; a semiquantitative plate culture method was used as the reference test for bacteriuria, and the Gram stain or a quantitative chamber count method was used as the reference test for pyuria. Each test was evaluated for its ability to detect probable pathogens at greater than or equal to 10(2) CFU/ml and/or greater than or equal to 1 leukocyte per oil immersion field, as determined by the Gram stain method, or greater than 10 leukocytes per microliter, as determined by the quantitative count method. A total of 1,500 urine specimens were included in this evaluation. There were 298 specimens with greater than or equal 10(2) CFU/ml and 451 specimens with pyuria. Of the 298 specimens with probable pathogens isolated at various colony counts, 219 specimens had colony counts of greater than or equal to 10(5) CFU/ml, 51 specimens had between 10(4) and 10(5) CFU/ml, and 28 specimens had between 10(2) and less than 10(4) CFU/ml. Both the URISCREEN and the Chemstrip LN detected 93% (204 of 219) of the specimens with probable pathogens at greater than or equal to 10(5) CFU/ml. For the specimens with probable pathogens at greater than or equal to 10(2) CFU/ml, the sensitivities of the URISCREEN and the Chemstrip LN were 86% (256 of 298) and 81% (241 of 298), respectively. Of the 451 specimens with pyuria, the URISCREEN detected 88% (398 of 451) and Chemstrip LN detected 78% (350 if 451). There were 204 specimens with both greater than or equal to 10(2) CFU/ml and pyuria; the sensitivities of both methods were 95% (193 of 204) for these specimens. Overall, there were 545 specimens with probable pathogens at greater than or equal to 10(2) CFU/ml and/or pyuria. The URISCREEN detected 85% (461 of 545), and the Chemstrip LN detected 73% (398 of 545). A majority (76%) of the false-negative results obtained with either method were for specimens without leukocytes in the urine. There were 955 specimens with no probable pathogens or leukocytes. Of these, 28% (270 of 955) were found positive by the URISCREEN and 13% (122 of 955) were found positive by the Chemstrip LN. A majority of the false-positive results were probably due, in part, to the detection of enzymes present in both bacterial and somatic cells by each of the test systems. Overall, the URISCREEN is rapid, manual, easy-to-perform enzymatic test that yields findings similar to those yielded by the Chemstrip LN for specimens with both greater than or equal to 10(2) CFU/ml and pyuria or for specimens with greater than or equal to 10(5) CFU/ml and with or without pyuria. However, when the data were analyzed for either probable pathogens at less 10(5) CFU/ml or pyuria, the sensitivity of the URISCREEN was higher (P less than 0.05). PMID:1551986
Spaan, Suzanne; Pronk, Anjoeka; Koch, Holger M.; Jusko, Todd A.; Jaddoe, Vincent W.V.; Shaw, Pamela A.; Tiemeier, Henning M.; Hofman, Albert; Pierik, Frank H.; Longnecker, Matthew P.
2014-01-01
The widespread use of organophosphate (OP) pesticides has resulted in ubiquitous exposure in humans, primarily through their diet. Exposure to OP pesticides may have adverse health effects, including neurobehavioral deficits in children. The optimal design of new studies requires data on the reliability of urinary measures of exposure. In the present study, urinary concentrations of six dialkyl phosphate (DAP) metabolites, the main urinary metabolites of OP pesticides, were determined in 120 pregnant women participating in the Generation R Study in Rotterdam. Intra-class correlation coefficients (ICCs) across serial urine specimens taken at <18, 18–25, and >25 weeks of pregnancy were determined to assess reliability. Geometric mean total DAP metabolite concentrations were 229 (GSD 2.2), 240 (GSD 2.1), and 224 (GSD 2.2) nmol/g creatinine across the three periods of gestation. Metabolite concentrations from the serial urine specimens in general correlated moderately. The ICCs for the six DAP metabolites ranged from 0.14 to 0.38 (0.30 for total DAPs), indicating weak to moderate reliability. Although the DAP metabolite levels observed in this study are slightly higher and slightly more correlated than in previous studies, the low to moderate reliability indicates a high degree of within-person variability, which presents challenges for designing well-powered epidemiologic studies. PMID:25515376
Residual cannabis levels in blood, urine and oral fluid following heavy cannabis use.
Odell, Morris S; Frei, Matthew Y; Gerostamoulos, Dimitri; Chu, Mark; Lubman, Dan I
2015-04-01
An understanding of tetrahydrocannabinol (THC) kinetics and residual levels after cannabis use is essential in interpreting toxicology tests in body fluids from live subjects, particularly when used in forensic settings for drug abuse, traffic and interpersonal violence cases. However the current literature is largely based on laboratory studies using controlled cannabis dosages in experienced users, with limited research investigating the kinetics of residual THC concentrations in regular high dose cannabis users. Twenty-one dependent cannabis users were recruited at admission to two residential detoxification units in Melbourne, Australia. After being provided with information about, and consenting to, the study, subjects volunteered to provide once-daily blood, urine and oral fluid (saliva) samples for seven consecutive days following admission, involving cessation and abstinence from all cannabis use. Blood and oral fluid specimens were analysed for THC and urine specimens for the metabolite THC-COOH. In some subjects THC was detectable in blood for at least 7 days and oral fluid specimens were positive for THC up to 78 h after admission to the unit. Urinary THC-COOH concentrations exceeded 1000 ng/mL for some subjects 129 h after last use. The presented blood THC levels are higher and persist longer in some individuals than previously described, our understanding and interpretation of THC levels in long term heavy cannabis users may need to be reconsidered. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Hanna, C P; Tyson, J F; McIntosh, S
1993-08-01
A method has been developed for the determination of inorganic arsenic [As(III) and As(V)] and its organic metabolites (monomethylarsenic and dimethylarsenic) in urine by flow-injection hydride generation atomic absorption spectrometry. The nontoxic seafood-derived arsenobetaine and arsenocholine species were first separated by a solid-phase extraction procedure. The remaining sample was digested with a mixture of nitric and sulfuric acids and potassium dichromate, followed by attack with hydrogen peroxide. The resulting As(V) was reduced to As(III) with potassium iodide in hydrochloric acid before injection into the flow-injection manifold. The percentage analytical recoveries (mean +/- 95% confidence interval) of various arsenic species added to a urine specimen at 250 micrograms/L were 108 +/- 2, 112 +/- 11, 104 +/- 7, and 95 +/- 5 for As(III), As(V), monomethylarsenic, and dimethylarsenic, respectively. For the determination of arsenic in Standard Reference Material 2670 (toxic metals in human urine), results agreed with the certified value (480 +/- 100 micrograms/L). Analyses of samples for the Centre de Toxicologie du Quebec, containing seafood-derived species, demonstrated the viability of the separation procedure. Detection limits were between 0.1 and 0.2 microgram/L in the solution injected into the manifold, and precision at 10 micrograms/L was between 2% and 3% (CV). These preliminary results show that the method might be applicable to determinations of arsenic in a range of clinical urine specimens.
Comparative evaluation of three commercial systems for nucleic acid extraction from urine specimens.
Tang, Yi-Wei; Sefers, Susan E; Li, Haijing; Kohn, Debra J; Procop, Gary W
2005-09-01
A nucleic acid extraction system that can handle small numbers of specimens with a short test turnaround time and short hands-on time is desirable for emergent testing. We performed a comparative validation on three systems: the MagNA Pure compact system (Compact), the NucliSens miniMAG extraction instrument (miniMAG), and the BioRobot EZ1 system (EZ1). A total of 75 urine specimens submitted for polyomavirus BK virus detection were used. The human beta-actin gene was detected on 75 (100%), 75 (100%), and 72 (96%) nucleic acid extracts prepared by the miniMAG, EZ1, and Compact, respectively. The miniMAG produced the highest quantity of nucleic acids and the best precision among the three systems. The agreement rate was 100% for BKV detection on nucleic acid extracts prepared by the three extraction systems. When a full panel of specimens was run, the hands-on time and test turnaround time were 105.7 and 121.1 min for miniMAG, 6.1 and 22.6 min for EZ1, and 7.4 and 33.7 min for Compact, respectively. The EZ1 and Compact systems processed automatic nucleic acid extraction properly, providing a good solution to the need for sporadic but emergent specimen detection. The miniMAG yielded the highest quantity of nucleic acids, suggesting that this system would be the best for specimens containing a low number of microorganisms of interest.
Adenovirus is a key pathogen in hemorrhagic cystitis associated with bone marrow transplantation.
Akiyama, H; Kurosu, T; Sakashita, C; Inoue, T; Mori Si; Ohashi, K; Tanikawa, S; Sakamaki, H; Onozawa, Y; Chen, Q; Zheng, H; Kitamura, T
2001-05-01
Late-onset hemorrhagic cystitis (HC) is a well-known complication of bone marrow transplantation (BMT) that is mainly attributed to infection with BK virus (BKV) and adenovirus (AdV). From 1986 through 1998, 282 patients underwent BMT, and 45 of them developed HC. Urine samples tested positive for AdV in 26 patients, of which 22 showed virus type 11. Among patients who underwent allogeneic BMT, logistic regression analysis revealed acute graft-versus-host disease (grade, > or = 2) to be the most significant predictive factor for HC (P < .0001). In addition, a total of 193 urine samples regularly obtained from 26 consecutive patients who underwent allogeneic BMT were examined for BKV, JC virus (JCV), and AdV by means of polymerase chain reaction. Of patients without HC, approximately 30% of the specimens tested positive for BKV (58 samples) and JCV (55 samples), whereas 5 (3%) tested positive for AdV. Of the 3 samples obtained from patients with HC, the numbers of positive results for BKV, JCV, and AdV were 3, 1, and 1, respectively; the numbers of positive results increased to 14 of 17, 9 of 17, and 10 of 17, respectively, when we added another 14 samples obtained from 14 patients with HC (P < .0001, P = .026, and P < .0001, respectively). In conclusion, there was significant correlation between AdV and HC in the patients we studied.
Veland, Nicolas; Espinosa, Diego; Valencia, Braulio Mark; Ramos, Ana Pilar; Calderon, Flor; Arevalo, Jorge; Low, Donald E.; Llanos-Cuentas, Alejandro; Boggild, Andrea K.
2011-01-01
We hypothesized that Leishmania kDNA may be present in urine of patients with cutaneous leishmaniasis (CL). Urine samples and standard diagnostic specimens were collected from patients with skin lesions. kDNA polymerase chain reaction (PCR) was performed on samples from patients and 10 healthy volunteers from non-endemic areas. Eighty-six of 108 patients were diagnosed with CL and 18 (21%) had detectable Leishmania Viannia kDNA in the urine. Sensitivity and specificity were 20.9% (95% confidence interval [CI] 12.3–29.5%) and 100%. Six of 8 patients with mucocutaneous involvement had detectable kDNA in urine versus 12 of 78 patients with isolated cutaneous disease (P < 0.001). L. (V.) braziliensis (N = 3), L. (V.) guyanensis (N = 6), and L. (V.) peruviana (N = 3) were identified from urine. No healthy volunteer or patient with an alternate diagnosis had detectable kDNA in urine. Sensitivity of urine PCR is sub-optimal for diagnosis. On the basis of these preliminary data in a small number of patients, detectable kDNA in urine may identify less localized forms of infection and inform treatment decisions. PMID:21460009
Fang, Fang; Collins-Emerson, Julie M; Heuer, Cord; Hill, Fraser I; Tisdall, David J; Wilson, Peter R; Benschop, Jackie
2014-11-01
A study was performed to investigate interlaboratory test agreement between a research and a commercial veterinary diagnostic laboratory on blood and urine samples, and to investigate test agreement between blood, urine, and kidney samples (research laboratory) for leptospirosis diagnosis. Samples were sourced from 399 sheep and 146 beef cattle from a local abattoir. Interlaboratory agreement for real-time quantitative polymerase chain reaction (qPCR) results on urine samples was almost perfect (kappa = 0.90), despite the use of different amplification targets (DNA gyrase subunit B gene vs. 16s ribosomal RNA gene), chemistries (SYTO9 vs. TaqMan probe), and pre-PCR processing. Interlaboratory agreement for microscopic agglutination test (MAT) positivity was almost perfect (kappa = 0.93) for Leptospira borgpetersenii serovar Hardjo subtype Hardjobovis (Hardjobovis) but moderate (kappa = 0.53) for Leptospira interrogans serovar Pomona (Pomona). Among animals that had different titers recorded, higher Hardjobovis and lower Pomona titers were reported by the commercial laboratory than by the research laboratory (P < 0.005). These interlaboratory comparisons can assist researchers and diagnosticians in interpreting the sometimes discrepant test results. Within the research laboratory, the comparison of qPCR results on urine and kidney showed almost perfect agreement (kappa = 0.84), suggesting that the qPCR on these 2 specimens can be used interchangeably. The agreement between MAT positivity and urine and kidney qPCR results was fair (kappa = 0.32 and kappa = 0.33, respectively). However, the prevalence ratio of urine and kidney qPCR positivity in Hardjobovis-seropositive versus Hardjobovis-seronegative sheep indicated that Hardjobovis seropositivity found in sheep may be able to predict shedding or renal carriage. © 2014 The Author(s).
Estimation of Monocrotophos renal elimination half-life in humans.
Jose, Arun; Selvakumar, Ratnasamy; Peter, John Victor; Karthik, Gunasekaran; Fleming, Denise Helen; Fleming, Jude Joseph
2015-01-01
Monocrotophos, implicated in about 1/4th of organophosphate poisonings in our centre, is associated with the highest mortality (24%). Yet data on its pharmacokinetics in humans is limited. We estimated the renal elimination half-life of monocrotophos. Consecutive patients presenting with monocrotophos overdose over a 2-month period who had normal renal function were recruited. Monocrotophos in plasma and urine were quantitated by high-performance liquid chromatography. Urine was obtained from catheterised samples at 0-2, 2-4, 4-6, 6-8, 8-12 and 12-24 h. Plasma specimens were collected at the time of admission, and at the midpoint of the urine sample collections at 1, 3, 5, 7, 10, 15 and 21 h. Renal elimination half-life was calculated from the cumulative amount excreted in the urine. The cohort of 5 male patients, aged 35.8 ± 2.94 years, presented with typical organophosphate (cholinergic) toxidrome following intentional monocrotophos overdose. All patients required mechanical ventilation; one patient died. Plasma data was available from 5 patients and urine data from 3 patients. The median renal elimination half-life was 3.3 (range: 1.9-5.0 h). Plasma monocrotophos values, as natural log, fell in a linear fashion up to around 10 h after admission. After the 10-hour period, there was a secondary rise in values in all the 3 patients in whom sampling was continued after 10 h. A renal elimination half-life of 3.3 h for monocrotophos is consistent with a water-soluble compound which is rapidly cleared from the plasma. The secondary rise in plasma monocrotophos values suggests possible re-distribution. Determining the elimination profile of this compound will help develop better strategies for treatment.
The Gulf Long-Term Follow-Up Study (GuLF STUDY): Biospecimen collection at enrollment.
Engel, Lawrence S; Kwok, Richard K; Miller, Aubrey K; Blair, Aaron; Curry, Matthew D; McGrath, John A; Sandler, Dale P
2017-01-01
The 2010 Deepwater Horizon (DWH) explosion in the Gulf of Mexico led to the largest ever marine oil spill by volume. The GuLF STUDY is investigating possible adverse human health effects associated with oil spill activities. One objective of the study was to utilize biological specimens from study participants to examine spill-related adverse health effects. This study describes the methods for collecting, processing, shipping, and storing specimens during the enrollment phase of the study. GuLF STUDY participants living in Gulf States (Alabama, Florida, Louisiana, Mississippi, and eastern Texas) were eligible to complete a home visit at enrollment, one to three years after the DWH explosion. During this visit, blood, urine, toenail and hair clippings, and house dust samples were collected. Specimens were shipped overnight to a central processing laboratory in containers with cold and ambient temperature compartments. Most blood and urine specimens were then aliquoted and stored in liquid nitrogen vapor or at -80°C, with some samples stored at -20°C. A total of 11,193 participants completed a home visit, and over 99% provided at least one biospecimen. Most participants provided blood (93%), urine (99%), and toenail clippings (89%), and 40% provided hair. Nearly all participants (95%) provided house-dust samples. Most samples were received by the laboratory one (58%) or two (25%) days after collection. These biospecimens enable investigation of a range of biomarkers of spill-related adverse health effects, and possibly some biomarkers of spill-related exposures. The biospecimen collection, handling, and storage protocols were designed to maximize current and future scientific value within logistical and budgetary constraints and might serve as a template for future studies conducted in similar time-critical and geographically dispersed settings.
Robandt, P V; Klette, K L; Sibum, M
2009-10-01
An automated solid-phase extraction coupled with liquid chromatography and tandem mass spectrometry (SPE-LC-MS-MS) method for the analysis of 11-nor-Delta(9)-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) in human urine specimens was developed. The method was linear (R(2) = 0.9986) to 1000 ng/mL with no carryover evidenced at 2000 ng/mL. Limits of quantification and detection were found to be 2 ng/mL. Interrun precision was evaluated at the 15 ng/mL level over nine batches spanning 15 days (n = 45). The coefficient of variation (%CV) was found to be 5.5% over the course of the validation. Intrarun precision of a 15 ng/mL control (n = 5) ranged from 0.58% CV to 7.4% CV for the same set of analytical batches. Interference was tested using (+/-)-11-hydroxy-Delta(9)-tetrahydrocannabinol, cannabidiol, (-)-Delta(8)-tetrahydrocannabinol, and cannabinol. One hundred and nineteen specimens previously found to contain THC-COOH by a previously validated gas chromatographic mass spectrometry (GC-MS) procedure were compared to the SPE-LC-MS-MS method. Excellent agreement was found (R(2) = 0.9925) for the parallel comparison study. The automated SPE procedure eliminates the human factors of specimen handling, extraction, and derivatization, thereby reducing labor costs and rework resulting from human error or technique issues. Additionally, method runtime is greatly reduced (e.g., during parallel studies the SPE-LC-MS-MS instrument was often finished with analysis by the time the technician finished the offline SPE and derivatization procedure prior to the GC-MS analysis).
Mercury Exposure in Young Children Living in New York City
Jeffery, Nancy; Kieszak, Stephanie; Fritz, Pat; Spliethoff, Henry; Palmer, Christopher D.; Parsons, Patrick J.; Kass, Daniel E.; Caldwell, Kathy; Eadon, George; Rubin, Carol
2007-01-01
Residential exposure to vapor from current or previous cultural use of mercury could harm children living in rental (apartment) homes. That concern prompted the following agencies to conduct a study to assess pediatric mercury exposure in New York City communities by measuring urine mercury levels: New York City Department of Health and Mental Hygiene’s (NYCDOHMH) Bureau of Environmental Surveillance and Policy, New York State Department of Health/Center for Environmental Health (NYSDOHCEH), Wadsworth Center’s Biomonitoring Program/Trace Elements Laboratory (WC-TEL), and Centers for Disease Control and Prevention (CDC). A previous study indicated that people could obtain mercury for ritualistic use from botanicas located in Brooklyn, Manhattan, and the Bronx. Working closely with local community partners, we concentrated our recruiting efforts through health clinics located in potentially affected neighborhoods. We developed posters to advertise the study, conducted active outreach through local partners, and, as compensation for participation in the study, we offered a food gift certificate redeemable at a local grocer. We collected 460 urine specimens and analyzed them for total mercury. Overall, geometric mean urine total mercury was 0.31 μg mercury/l urine. One sample was 24 μg mercury/l urine, which exceeded the (20 μg mercury/l urine) NYSDOH Heavy Metal Registry reporting threshold for urine mercury exposure. Geometric mean urine mercury levels were uniformly low and did not differ by neighborhood or with any clinical significance by children’s ethnicity. Few parents reported the presence of mercury at home, in a charm, or other item (e.g., skin-lightening creams and soaps), and we found no association between these potential sources of exposure and a child’s urinary mercury levels. All pediatric mercury levels measured in this study were well below a level considered to be of medical concern. This study found neither self-reported nor measured evidence of significant mercury use or exposure among participating children. Because some participants were aware of the possibility that they could acquire and use mercury for cultural or ritualistic purposes, community education about the health hazards of mercury should continue. PMID:17957474
Work up of Pediatric Urinary Tract Infection
Copp, Hillary L.; Schmidt, Bogdana
2016-01-01
Pediatric UTI costs the healthcare system upwards of 180 million dollars annually, and accounts for over 1.5 million clinician visits per year. Accurate and timely diagnosis of these infections is important for determining appropriate treatment and preventing long-term complications such as renal scarring, hypertension, and end-stage renal disease. Outside of the first 12 months, girls are more likely to be diagnosed with a UTI. About half of boys with UTI will be diagnosed within the first 12 months of life. The prevalence and incidence of pediatric UTI varies by age, race/ethnicity, sex and circumcision status. Diagnosis of UTI is made based on history and exam findings and confirmed with appropriately collected urine. If a bag specimen is negative, this can be used to rule out UTI without the need for confirmatory culture; however positive urinalysis tests from bag specimen warrant further investigation with a catheterized specimen or suprapubic aspiration. Urine culture is the gold standard for diagnosing UTI: Greater than 50,000 CFU on a catheterized specimen or suprapubic aspiration indicate presence of a UTI. Greater than 100,000 CFU on a voided specimen is considered a positive culture. There is no consensus on the need and optimal strategy for imaging in the setting of urinary tract infection in the pediatric population. Prompt recognition of UTI and antibiogram-based, empiric treatment or culture-based, targeted treatment should be initiated within 72 of presentation. PMID:26475948
Urogenital tract infections in pregnancy at King Edward VIII Hospital, Durban, South Africa.
Dietrich, M; Hoosen, A A; Moodley, J; Moodley, S
1992-02-01
To evaluate the role of detecting asymptomatic bacteriuria and endocervical infections in the black prenatal patients attending King Edward VIII Hospital (KEH), Durban, with the view of justifying a screening programme. Screening for syphilis and human immunodeficiency virus (HIV) infection were also evaluated. 181 asymptomatic black prenatal patients attending the antenatal clinic for their first antenatal visit volunteered for the study and gave their written consent. Examination of each prenatal patient included obtaining of endocervical swabs to detect endocervical infections (C trachomatis, N gonorrhoeae), serum for syphilitic and HIV testing, and a midstream specimen of urine for microscopy and culture. Asymptomatic bacteriuria was found in 5.6% of patients in this study. Cervical infections were diagnosed microbiologically in 8.2% of women. These were N gonorrhoeae in 4.1% and C trachomatis in 4.7%. Serological tests for sexually transmitted diseases showed the presence of syphilis in 7.6% and antibody to the HIV in 1.9%. Overall, one or more sexually transmitted diseases were found in 16.5% of the women studied. This study suggests that all women presenting for routine antenatal care in a setting such as Durban should be screened for lower genital tract infections. Ideally this should include a midstream urine specimen for culture, serum for syphilitic and HIV antibody testing and endocervical swabs for sexually transmitted pathogens. In developing communities, however, more reliable and cheaper methods of endocervical screening need to be available before antenatal screening for cervico-vaginal infections can be justified.
Luong, Susan; Kuzhiumparambil, Unnikrishnan; Fu, Shanlin
2015-09-17
Currently, procedures that identify the drugs 'destroyed' in adulterated urine specimens are very limited. This study aimed to determine the effect of pyridinium chlorochromate (PCC) on routine opiate assays and identify reaction products formed. Results/methodology: Opiate-positive urines adulterated with PCC (20 and 100 mM) were analyzed using CEDIA ® immunoassay and GC-MS. Urine and water samples spiked with 6-monoacetylmorphine, morphine and its glucuronides (10 µg/ml) and PCC (0.02-100 mM) were monitored with LC-MS, and the products characterized. PCC significantly decreased the abundance of morphine, codeine and IS. Adulterated water and urine samples containing 6-monoacetylmorphine, morphine and morphine-3-glucuronide yielded morphinone-3-glucuronide, 7,14-dihydroxy-6-monoacetylmorphine, 7,8-diketo-6-monoacetylmorphine and 7,8-diketo-morphine (tentative assignment). Reaction pathways may be different in the two matrices.
Validity of predictive equations for 24-h urinary sodium excretion in adults aged 18–39 y12345
Wang, Chia-Yih; Chen, Te-Ching; Pfeiffer, Christine M; Elliott, Paul; Gillespie, Cathleen D; Carriquiry, Alicia L; Sempos, Christopher T; Liu, Kiang; Perrine, Cria G; Swanson, Christine A; Caldwell, Kathleen L; Loria, Catherine M
2013-01-01
Background: Collecting a 24-h urine sample is recommended for monitoring the mean population sodium intake, but implementation can be difficult. Objective: The objective was to assess the validity of published equations by using spot urinary sodium concentrations to predict 24-h sodium excretion. Design: This was a cross-sectional study, conducted from June to August 2011 in metropolitan Washington, DC, of 407 adults aged 18–39 y, 48% black, who collected each urine void in a separate container for 24 h. Four timed voids (morning, afternoon, evening, and overnight) were selected from each 24-h collection. Published equations were used to predict 24-h sodium excretion with spot urine by specimen timing and race-sex subgroups. We examined mean differences with measured 24-h sodium excretion (bias) and individual differences with the use of Bland-Altman plots. Results: Across equations and specimens, mean bias in predicting 24-h sodium excretion for all participants ranged from −267 to 1300 mg (Kawasaki equation). Bias was least with International Cooperative Study on Salt, Other Factors, and Blood Pressure (INTERSALT) equations with morning (−165 mg; 95% CI: −295, 36 mg), afternoon (−90 mg; −208, 28 mg), and evening (−120 mg; −230, −11 mg) specimens. With overnight specimens, mean bias was least when the Tanaka (−23 mg; 95% CI: −141, 95 mg) or Mage (−145 mg; −314, 25 mg) equations were used but was statistically significant when using the Tanaka equations among females (216 to 243 mg) and the Mage equations among races other than black (−554 to −372 mg). Significant over- and underprediction occurred across individual sodium excretion concentrations. Conclusions: Using a single spot urine, INTERSALT equations may provide the least biased information about population mean sodium intakes among young US adults. None of the equations evaluated provided unbiased estimates of individual 24-h sodium excretion. This trial was registered at clinicaltrials.gov as NCT01631240. PMID:24047921
[The etiology of urinary tract infections].
Avio, C M; Ceccherini, M; Pierotti, R; Falcone, G
1977-01-01
The Authors have planned a program in order to file and elaborate with a computer the results of urine cultures. From 8.600 specimens, about 86% were negative or doubtful. The data obtained from 1201 positive cultures were processed in order to state the absolute and relative frequency of the bacterial species isolated and their distribution according to their genera, antibiotic resistence, month and sex. Among the most representative species the pattern of antibiotic resistence was surveyed. E. coli shows very high frequency (38%). The frequency of Pseudomonas increases while staphylococci frequency decreases as compared with the previous statements of various Authors. The analysis of the antibiotic sensitivity spectrum of 534 specimens shows that about 50% of E. coli strains are sensitive to 10, 11 and 12 antibiotics and their pattern of resistence involves no more than 9 antibiotics; on the contrary more than 60% of Pseudomonas and Proteus rettgeri are resistant to 10, 11 or 12 antibiotics and at any rate to no less than seven. Enterobacter and Proteus mirabilis present an intermediate pattern of resistence.
[Microbiota of urine and vagina of healthy postmenopausal women (a pilot study)].
Naboka, Yu L; Rymashevsky, A N; Kogan, M I; Gudima, I A; Borovleva, O A; Jalagonia, K T; Zarutskiy, S A
2016-02-01
Studying microbiota of different urogenital tract habitats in healthy postmenopausal women is of practical importance in deciding on the appropriateness of correction of dysbiotic disorders. The aim of this study was to examine the vaginal and urine microbiota of healthy postmenopausal women. The study included 20 healthy postmenopausal women (mean age 59,0+/-2,1 years). Duration of menopause in all subjects was more than 8 years. Bacteriological testing of urine and vaginal specimen was carried out on the extended media (15) for cultivating facultative anaerobic bacteria (FAB) and nonclostridial anaerobic bacteria (NAB) and included PCR of midstream morning urine. Among FAB in the urine and vagina dominated coagulase-negative staphylococci and NAB. Bacterial patterns of studied habitats turned out to be similar in many respects. In the urine Megasphaera spp., Veillonella spp., Prevotella spp., Mobiluncus spp., Fusobacterium spp. were found, whereas in the vagina these microorganisms were not present. Cluster analysis revealed no significant differences in the concentration of the same microorganisms isolated from the urine and vagina. When comparing the frequency of microorganism detection in urine by bacteriological method and by PCR, bacterial patterns were identical in 56% of cases.
Knittel, Jessica L.; Holler, Justin M.; Chmiel, Jeffrey D.; Vorce, Shawn P.; Magluilo, Joseph; Levine, Barry; Ramos, Gerardo; Bosy, Thomas Z.
2016-01-01
Synthetic cannabinoids emerged on the designer drug market in recent years due to their ability to produce cannabis-like effects without the risk of detection by traditional drug testing techniques such as immunoassay and gas chromatography–mass spectrometry. As government agencies work to schedule existing synthetic cannabinoids, new, unregulated and structurally diverse compounds continue to be developed and sold. Synthetic cannabinoids undergo extensive metabolic conversion. Consequently, both blood and urine specimens may play an important role in the forensic analysis of synthetic cannabinoids. It has been observed that structurally similar synthetic cannabinoids follow common metabolic pathways, which often produce metabolites with similar metabolic transformations. Presented are two validated quantitative methods for extracting and identifying 15 parent synthetic cannabinoids in blood, 17 synthetic cannabinoid metabolites in urine and the qualitative identification of 2 additional parent compounds. The linear range for most synthetic cannabinoid compounds monitored was 0.1–10 ng/mL with the limit of detection between 0.01 and 0.5 ng/mL. Selectivity, specificity, accuracy, precision, recovery and matrix effect were also examined and determined to be acceptable for each compound. The validated methods were used to analyze a compilation of synthetic cannabinoid investigative cases where both blood and urine specimens were submitted. The study suggests a strong correlation between the metabolites detected in urine and the parent compounds found in blood. PMID:26792810
Preanalytical requirements of urinalysis
Delanghe, Joris; Speeckaert, Marijn
2014-01-01
Urine may be a waste product, but it contains an enormous amount of information. Well-standardized procedures for collection, transport, sample preparation and analysis should become the basis of an effective diagnostic strategy for urinalysis. As reproducibility of urinalysis has been greatly improved due to recent technological progress, preanalytical requirements of urinalysis have gained importance and have become stricter. Since the patients themselves often sample urine specimens, urinalysis is very susceptible to preanalytical issues. Various sampling methods and inappropriate specimen transport can cause important preanalytical errors. The use of preservatives may be helpful for particular analytes. Unfortunately, a universal preservative that allows a complete urinalysis does not (yet) exist. The preanalytical aspects are also of major importance for newer applications (e.g. metabolomics). The present review deals with the current preanalytical problems and requirements for the most common urinary analytes. PMID:24627718
Lobo, Maria Luísa; Xiao, Lihua; Antunes, Francisco; Matos, Olga
2012-02-01
Despite recent advances in the understanding and diagnosis of emerging microsporidian pathogens, more research is necessary to elucidate their complex epidemiology. In fact, studies that reflect true human-infecting microsporidian prevalence are still inadequate. The present 10-year study was undertaken to examine the occurrence of Microsporidia in 1989 stools, 69 urine and 200 pulmonary specimens from HIV-positive and HIV-negative patients using PCR and DNA sequencing. In stools, 12.0% were Microsporidia-positive. Prevalences of 13.9% and 8.5% were observed for HIV+ and HIV- samples, respectively. The percentage of children that were Microsporidia-positive (18.8%) was significantly higher than that of adults (10.2%). In stools, Enterocytozoon bieneusi (6.3%) and Vittaforma-like parasites (6.8%) were identified. Based on the internal transcribed spacer (ITS) region of E. bieneusi, Type IV (37.5%), Peru 6 (29.2%), D (12.5%), A (8.3%), C (6.3%) and PtEb II (6.3%) genotypes were identified. Microsporidia were detected in 1.5% and 1.0% of urine and pulmonary specimens, respectively. Encephalitozoonintestinalis was detected in urine. In pulmonary specimens, Encephalitozoon cuniculi and Vittaforma-like parasites were identified. An immunosuppressive condition and youth (children) appear to be risk factors for microsporidian infection. Microsporidia seems to have an important impact on public health in Portugal, highlighting the need to implement routine diagnosis. Copyright © 2012 Australian Society for Parasitology Inc. Published by Elsevier Ltd. All rights reserved.
Steuerwald, Amy J.; Parsons, Patrick J.; Arnason, John G.; Chen, Zhen; Peterson, C. Matthew; Louis, Germaine M. Buck
2013-01-01
Analysis of human urine is commonly used in biomonitoring studies to assess exposure to essential (e.g., Cu, Zn, Se) and non-essential (Pb, Cd, Pt) trace elements. These data are also used in epidemiological studies to evaluate potential associations between trace element exposure and various health outcomes within a population. Today most trace element analyses are typically performed using quadrupole-based inductively coupled plasma mass spectrometry (Q-ICP-MS). However, there is always the potential for spectral interferences with Q-ICP-MS instrumentation, especially when analyzing human specimens that may contain medications and other exogenous substances. Moreover, such xenobiotics may be unknown to the investigators. In a recent study focusing on environmental exposures and endometriosis: Endometriosis: Natural History, Diagnosis, and Outcomes (ENDO Study), urine specimens (n=619) were collected from participating women upon enrollment into the study or prior to surgery or pelvic magnetic resonance imaging (MRI), and analyzed for 21 trace elements by Q-ICP-MS. Here we report on some anomalous results observed for Se and Pt with elevated concentrations up to several orders of magnitude greater than what might be expected based on established reference intervals. Further investigations using Sector Field (SF-) ICP-MS instrumentation led to identification of doubly charged and polyatomic gadolinium (Gd) species traced to a Gd-based contrast agent that was administered to some subjects just prior to urine collection. Specifically, interferences from Gd2+ and several minor polyatomics were identified as interferences on all of the major isotopes of Se including 74Se, 76Se, 77Se, 78Se, 80Se, and 82Se. While trace amounts of Pt were present in the urine, a number of Gd-containing polyatomic species were also evident as major interferences on all isotopes of Pt (190Pt, 192Pt, 194Pt, 195Pt, 196Pt, and 198Pt), including Gd-chlorides, Gd-argides, and Gd-oxides. These observations underscore the importance of considering potential isobaric interferences when interpreting unusual trace element results for clinical specimens. PMID:27397951
Gaydos, C. A.; Davis, T.; Marrazzo, J.; Furgerson, D.; Taylor, S. N.; Smith, B.; Bachmann, L. H.; Ackerman, R.; Spurrell, T.; Ferris, D.; Burnham, C.-A. D.; Reno, H.; Lebed, J.; Eisenberg, D.; Kerndt, P.; Philip, S.; Jordan, J.; Quigley, N.
2017-01-01
ABSTRACT Trichomoniasis is the most prevalent curable sexually transmitted disease (STD). It has been associated with preterm birth and the acquisition and transmission of HIV. Recently, nucleic acid amplification tests (NAAT) have been FDA cleared in the United States for detection of Trichomonas vaginalis in specimens from both women and men. This study reports the results of a multicenter study recently conducted using the Xpert TV (T. vaginalis) assay to test specimens from both men and women. On-demand results were available in as little as 40 min for positive specimens. A total of 1,867 women and 4,791 men were eligible for inclusion in the analysis. In women, the performance of the Xpert TV assay was compared to the patient infected status (PIS) derived from the results of InPouch TV broth culture and Aptima NAAT for T. vaginalis. The diagnostic sensitivities and specificities of the Xpert TV assay for the combined female specimens (urine samples, self-collected vaginal swabs, and endocervical swabs) ranged from 99.5 to 100% and 99.4 to 99.9%, respectively. For male urine samples, the diagnostic sensitivity and specificity were 97.2% and 99.9%, respectively, compared to PIS results derived from the results of broth culture for T. vaginalis and bidirectional gene sequencing of amplicons. Excellent performance characteristics were seen using both female and male specimens. The ease of using the Xpert TV assay should result in opportunities for enhanced screening for T. vaginalis in both men and women and, hopefully, improved control of this infection. PMID:29167292
Diagnosis of neonatal group B Streptococcus sepsis by nested-PCR of residual urine samples
Cezarino, Bruno Nicolino; Yamamoto, Lidia; Del Negro, Gilda Maria Barbaro; Rocha, Daisy; Okay, Thelma Suely
2008-01-01
Group B streptococcus (GBS) remains the most common cause of early-onset sepsis in newborns. Laboratory gold-standard, broth culture methods are highly specific, but lack sensitivity. The aim of this study was to validate a nested-PCR and to determine whether residue volumes of urine samples obtained by non invasive, non sterile methods could be used to confirm neonatal GBS sepsis. The nested-PCR was performed with primers of the major GBS surface antigen. Unavailability of biological samples to perform life supporting exams, as well as others to elucidate the etiology of infections is a frequent problem concerning newborn patients. Nevertheless, we decided to include cases according to strict criteria: newborns had to present with signs and symptoms compatible with GBS infection; at least one of the following biological samples had to be sent for culture: blood, urine, or cerebrospinal fluid; availability of residue volumes of the samples sent for cultures, or of others collected on the day of hospitalization, prior to antibiotic therapy prescription, to be analyzed by PCR; favorable outcome after GBS empiric treatment. In only one newborn GBS infection was confirmed by cultures, while infection was only presumptive in the other three patients (they fulfilled inclusion criteria but were GBS-culture negative). From a total of 12 biological samples (5 blood, 3 CSF and 4 urine specimen), eight were tested by culture methods (2/8 were positive), and 8 were tested by PCR (7/8 were positive), and only 4 samples were simultaneously tested by both methods (1 positive by culture and 3 by PCR). In conclusion, although based on a restricted number of neonates and samples, our results suggest that the proposed nested-PCR might be used to diagnose GBS sepsis as it has successfully amplified the three types of biological samples analyzed (blood, urine and cerebrospinal fluid), and was more sensitive than culture methods as PCR in urine confirmed diagnosis in all four patients. Moreover, PCR has enabled us to use residue volumes of urine samples collected by non invasive, non sterile methods, what is technically adequate as GBS is not part of the normal urine flora, thus avoiding invasive procedures such as suprapubic bladder punction or transurethral catheterization. At the same time, the use of urine instead of blood samples could help preventing newborns blood spoliation. PMID:24031170
Aramendía, Maite; Rello, Luis; Vanhaecke, Frank; Resano, Martín
2012-10-16
Collection of biological fluids on clinical filter papers shows important advantages from a logistic point of view, although analysis of these specimens is far from straightforward. Concerning urine analysis, and particularly when direct trace elemental analysis by laser ablation-inductively coupled plasma mass spectrometry (LA-ICPMS) is aimed at, several problems arise, such as lack of sensitivity or different distribution of the analytes on the filter paper, rendering obtaining reliable quantitative results quite difficult. In this paper, a novel approach for urine collection is proposed, which circumvents many of these problems. This methodology consists on the use of precut filter paper discs where large amounts of sample can be retained upon a single deposition. This provides higher amounts of the target analytes and, thus, sufficient sensitivity, and allows addition of an adequate internal standard at the clinical lab prior to analysis, therefore making it suitable for a strategy based on unsupervised sample collection and ulterior analysis at referral centers. On the basis of this sampling methodology, an analytical method was developed for the direct determination of several elements in urine (Be, Bi, Cd, Co, Cu, Ni, Sb, Sn, Tl, Pb, and V) at the low μg L(-1) level by means of LA-ICPMS. The method developed provides good results in terms of accuracy and LODs (≤1 μg L(-1) for most of the analytes tested), with a precision in the range of 15%, fit-for-purpose for clinical control analysis.
Hardt, Nancy; Wong, Tit D; Burt, Martha J; Harrison, Ross; Winter, Will; Roth, Jeffrey
2013-11-01
Abuse of prescription and illicit drugs has been rapidly increasing. This study examines the prevalence of drug use in the non-natural deaths of pregnant or recently pregnant women. Records from Florida's Pregnancy Associated Mortality Review conducted between 1999 and 2005 (n = 415) were linked to 385 toxicology reports obtained from Florida medical examiners' offices. The final study sample consisted of 169 drug-positive, pregnancy-associated non-natural deaths. Of these, 86 were positive for both blood and urine, 64 were positive for blood only and five for urine only, and the remainder were positive for some other specimen. Among these deaths, 91 cases (54%) involved prescription drugs, 78 cases (46%) involved illicit drugs, and 69 cases (41%) involved alcohol. Opioids constituted the majority of deaths associated with prescription drugs. Substantial co-use of opioids and benzodiazepines was seen. Pregnant or recently pregnant women may have more interactions with healthcare providers, which may present more opportunities for intervention and prevention. © 2013 American Academy of Forensic Sciences.
Urine culture - catheterized specimen
... you may feel pressure. If you have a urinary tract infection , you may have some pain when the catheter ... on their own If you might have a urinary tract infection If you cannot empty your bladder (urinary retention) ...
78 FR 3920 - Information Collection; Paperwork Reduction Act; 60-Day Notice
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-17
... counties. Data collected include a personal interview and urine specimen taken within 48 hours of arrest... collect data concerning the personal drug use, drug and alcohol treatment, arrests, and drug market...
Urine specimen detection of zolpidem use in patients with pain.
Mann, Lindsey M; Atayee, Rabia S; Best, Brookie M; Morello, Candis M; Ma, Joseph D
2014-01-01
This study examined zolpidem and concurrent opioid, benzodiazepine, other central nervous system (CNS) depressants, and alcohol use. Urine specimens were analyzed using liquid chromatography-mass spectrometry (LC-MS/MS). Specimens were tested for zolpidem (n = 71,919) and separated into a provider-reported medication list documenting (n = 5,257) or not documenting zolpidem use (n = 66,662). Zolpidem-positive specimens were further separated into reported and unreported use cohorts. The total number of zolpidem-positive specimens in the reported and unreported use cohorts was 3,391 and 3,190, respectively. Non-informed prescribers were 4.4% (3,190/71,919) among the general population and 48.5% (3,190/6,581) when only zolpidem users were considered. In the zolpidem user population, the most common concurrent opioids in both cohorts were hydrocodone and oxycodone. Alprazolam and clonazepam were higher in the unreported use cohort (P ≤ 0.05). The unreported use cohort also had a higher detection of zolpidem plus a benzodiazepine (49.7 vs. 46%; P ≤ 0.05), zolpidem plus an opioid and a benzodiazepine (40.8% vs. 37.4%; P ≤ 0.05) and zolpidem plus an opioid, a benzodiazepine, and an other CNS depressant (12.9 vs. 10.9%; P ≤ 0.05). Concurrent use of zolpidem, an opioid, a benzodiazepine and an other CNS depressant is prevalent in a pain patient population. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Sycamore, K F; Poorbaugh, V R; Pullin, S S; Ward, C R
2014-07-01
To compare aerobic bacterial culture of urine to cystoscopically obtained mucosal biopsies of the lower urinary tract in dogs. Retrospective review of case records from dogs that had transurethral cystoscopy at a veterinary teaching hospital between 2002 and 2011. Dogs that had culture results from cystocentesis obtained urine and transurethral cystoscopically obtained mucosal samples were included in the study. Pathogens identified were compared between sampling methods. Forty dogs underwent transurethral cystoscopy for lower urinary tract disease on 41 occasions. There was significant (P = 0 · 0003) agreement between urine and mucosal biopsy cultures. Both cultures were negative in 66% and positive in 17% of dogs. There was a 17% disagreement between the sampling methods. Although not statistically significant, more mucosal samples than urine cultures were positive for Escherichia coli. There was a good agreement between pathogen identification from urine and lower urinary tract mucosal cultures. These results do not support the utilisation of transurethral cystoscopy to obtain biopsy samples for culture in dogs with urinary tract infection and positive urine culture. Individual cases with possible chronic urinary tract infection and negative urine culture may benefit from transurethral cystoscopy to obtain biopsies for culture. © 2014 British Small Animal Veterinary Association.
Fiore, D; Auger, F A; Drusano, G L; Dandu, V R; Lesko, L J
1984-01-01
A rapid, sensitive, and specific method of analysis for mezlocillin in serum and urine by high-pressure liquid chromatography is described. A solid-phase extraction column was used to remove interfering substances from samples before chromatography. Quantitation included the use of an internal standard, nafcillin. Mezlocillin was chromatographed with a phosphate buffer-acetonitrile (73:27) mobile phase and a C-18 reverse-phase column and detected at a wavelength of 220 nm. The assay had a sensitivity of 1.6 micrograms/ml and a linearity of up to 600 micrograms/ml and 16 mg/ml in serum and urine, respectively, with only 0.1 ml of sample. The interday and intraday coefficients of variation for replicate analyses of spiked serum and urine specimens were less than 6.5%. PMID:6517560
Rowat, Anne; Smith, Laura; Graham, Cat; Lyle, Dawn; Horsburgh, Dorothy; Dennis, Martin
2011-09-01
The purpose of this pilot study was to examine whether urine specific gravity and urine colour could provide an early warning of dehydration in stroke patients compared with standard blood indicators of hydration status. Dehydration after stroke has been associated with increased blood viscosity, venous thrombo-embolism and stroke mortality at 3-months. Earlier identification of dehydration might allow us to intervene to prevent significant dehydration developing or reduce its duration to improve patient outcomes. We recruited 20 stroke patients in 2007 and measured their urine specific gravity with urine test strips, a refractometer, and urine colour of specimens taken daily on 10 consecutive days and compared with the routine blood urea:creatinine ratios over the same period to look for trends and relationships over time. The agreement between the refractometer, test strips and urine colour were expressed as a percentage with 95% confidence intervals. Nine (45%) of the 20 stroke patients had clinical signs of dehydration and had a significantly higher admission median urea:creatinine ratio (P = 0·02, Mann-Whitney U-test). There were no obvious relationships between urine specific gravity and urine colour with the urea:creatinine ratio. Of the 174 urine samples collected, the refractometer agreed with 70/174 (40%) urine test strip urine specific gravity and 117/174 (67%) urine colour measurements. Our results do not support the use of the urine test strip urine specific gravity as an early indicator of dehydration. Further research is required to develop a practical tool for the early detection of dehydration in stroke patients. © 2011 Blackwell Publishing Ltd.
Betsou, Fotini; Beaumont, Katy; Sueur, Jean Marie; Orfila, Jeanne
2003-01-01
An internal control DNA (ICD) with the same primer binding sequences as the target Chlamydia trachomatis DNA was constructed and evaluated in a PCR assay with immunoenzymatic detection. One hundred urine specimens were tested, and 23 were found to contain inhibitors of the PCR, if not subjected to DNA extraction prior to amplification. Coamplification and detection of the ICD appeared to be a useful method for estimating the effects of inhibitors on C. trachomatis DNA amplification. PMID:12624066
2009-06-01
Work was accomplished under approved task AM-B-09-TOX-206. 16. Abstract The Civil Aerospace Medical Institute’s toxicology laboratory...routine analysis of pilot specimens, the laboratory tests all cases for the presence of marijuana ( cannabis ). The National Institute on Drug Abuse... cannabis seizures from1997-2001 to 2002-2006. This study was conducted to compare the changes, over those years, in blood and urine cannabinoid
Cwiklińska, Agnieszka; Kąkol, Judyta; Kuchta, Agnieszka; Kortas-Stempak, Barbara; Pacanis, Anastasis; Rogulski, Jerzy; Wróblewska, Małgorzata
2012-02-01
Given the common problems with the standardization of urine particle counting methods and the great variability in the results obtained by Polish laboratories under international Labquality External Quality Assessment (EQA), we initiated educational recovery activities. Detailed instructions on how to perform the standardized examination were sent to EQA participants, as was a questionnaire forms which enabled information to be gathered in respect to the procedures being applied. Laboratory results were grouped according to the method declared on the EQA 'Result' form or according to a manual examination procedure established on the basis of the questionnaire. The between-laboratory CVs for leukocyte and erythrocyte counts were calculated for each group and compared using the Mann-Whitney test. Significantly lower between-laboratory CVs (p = 0.03) were achieved for leukocyte counting among the laboratories that analysed control specimens in accordance with standardized procedures as compared with those which used non-standardized procedures. We also observed a visible lower variability for erythrocyte counting. Unfortunately despite our activities, only a few of the Polish laboratories applied the standardized examination procedures, and only 29% of the results could have been considered to be standardized (16% - manual methods, 13% - automated systems). The standardization of urine particle counting methods continues to be a significant problem in medical laboratories and requires further recovery activities which can be conducted using the EQA scheme.
Evaluation of the Urine Protein/Creatinine Ratio Measured with the Dipsticks Clinitek Atlas PRO 12.
Hermida, Fernando J; Soto, Sonia; Benitez, Alfonso J
2016-01-01
Screening for urine proteins is recommended for the detection of albuminuria in high risk groups. The aim of this study was to compare the Clinitek Atlas PRO12 reagent urine strip with quantitative methods for the determination of protein/creatinine ratio and to evaluate the usefulness of the semi-quantitative Clinitek Atlas PRO12 reagent urine strip as a tool in the early detection of albuminuria among the general population. Six hundred first morning urine specimens were collected from outpatients with various clinical conditions. The results showed that the test data for the urine dipstick Clinitek Atlas PRO12 show good agreement with the quantitative measurement of protein, creatinine and protein/creatinine ratio. In addition, this study shows that 97.2% of the samples which gave "normal" protein/creatinine ratios by the semi-quantitative method, showed albumin/creatinine ratio < 30 mg/g by the quantitative methods. Our results show that Clinitek Atlas PRO12 reagent strips can be used for the purposes of albuminuria screening in the general population.
Enhanced urinalysis in the detection of asymptomatic bacteriuria in pregnancy.
Aigere, E O S; Okusanya, B O; Eigbefoh, J O; Okome, G B O
2013-01-01
Detection and treatment of asymptomatic bacteriuria (ASB) in pregnancy is important to avert the attendant maternal and fetal morbidity. Other than urine culture, no other screening test is unequivocal. The use of enhanced urinalysis test to detect ASB in pregnancy was investigated. This was a prospective observational study which compared enhanced urinalysis with dipstick tests and urine culture. Clean catch midstream urine specimen was collected from 150 consecutive asymptomatic pregnant women. Tests of validity were used for comparison. Enhanced urinalysis detected bacteriuria as much as urine culture (4% vs. 4.7%). Itwas 57.1% sensitive and 98.6% specific. It had a false negative rate of 42.9% and was 96.7% accurate when compared to urine culture. Enhanced urinalysis took 1-2 hours to be done and required skills to use the microscope and was more expensive than dipstick urinalysis. The accuracy of enhanced urinalysis and its ability to detect ASB as much as urine culture connotes that it can be used to detect asymptomatic bacteriuria in pregnancy albeit only in secondary and tertiary health centres because of the cost and technicality involved.
Salina, Margarete Aparecida; Shikanai-Yasuda, Maria Aparecida; Mendes, Rinaldo Poncio; Barraviera, Benedito; Mendes Giannini, Maria José Soares
1998-01-01
For the diagnosis and follow-up of paracoccidioidomycosis patients undergoing therapy, we evaluated two methods (immunoblotting and competition enzyme immunoassay) for the detection of circulating antigen in urine samples. A complex pattern of reactivity was observed in the immunoblot test. Bands of 70 and 43 kDa were detected more often in urine samples from patients before treatment. The immunoblot method detected gp43 and gp70 separately or concurrently in 11 (91.7%) of 12 patients, whereas the competition enzyme immunoassay detected antigenuria in 9 (75%) of 12 patients. Both tests appeared to be highly specific (100%), considering that neither fraction detectable by immunoblotting was present in urine samples from the control group. gp43 remained present in the urine samples collected during the treatment period, with a significant decrease in reactivity in samples collected during clinical recovery and increased reactivity in samples collected during relapses. Reactivity of some bands was also detected in urine specimens from patients with “apparent cure.” The detection of Paracoccidioides brasiliensis antigens in urine appears to be a promising method for diagnosing infection, for evaluating the efficacy of treatment, and for detecting relapse. PMID:9620407
Dai, Qingkai; Jiang, Yongmei; Shi, Hua; Zhou, Wei; Zhou, Shengjie; Yang, Hui
2014-01-01
Urinary tract infection (UTI) is a widespread disease in women. Urine culture is still the "gold standard" diagnostic test for UTI, but most of them are negative. To reduce unnecessary culture, we evaluated the automated urine particle analyzer UF-1000i screening for UTI in nonpregnant women. The urine specimens submitted to our laboratory were submitted for culture and tested by the Sysmex UF-1000i. Bacteria and white blood cell (WBC) counts were compared to standard urine culture results to assess the best cutoff values. In this study, 272 urine samples were included, of which 98 (36.0%) were culture positive with a bacterial cutoff value of 10 x 10(5) CFU/mL. A combination of bacterial (> 95/microL) and/or WBC count (> 24/microL) provided the best screening for UTI, with a sensitivity of 0.99 and a specificity of 0.82 compared with the urine culture. Sysmex UF-1000i could be used as a screening test for UTI in nonpregnant women. According to the distribution and range of the bacterial scattergram, we could primarily identify and differentiate between Gram-negative and Gram-positive bacteria.
Cantey, Joseph B; Gaviria-Agudelo, Claudia; McElvania TeKippe, Erin; Doern, Christopher D
2015-04-01
Urinary tract infection (UTI) is one of the most common infections in children. Urine culture remains the gold standard for diagnosis, but the utility of urine Gram stain relative to urinalysis (UA) is unclear. We reviewed 312 pediatric patients with suspected UTI who had urine culture, UA, and urine Gram stain performed from a single urine specimen. UA was considered positive if ≥10 leukocytes per oil immersion field were seen or if either nitrates or leukocyte esterase testing was positive. Urine Gram stain was considered positive if any organisms were seen. Sensitivity, specificity, and positive and negative predictive values were calculated using urine culture as the gold standard. Thirty-seven (12%) patients had a culture-proven UTI. Compared to urine Gram stain, UA had equal sensitivity (97.3% versus 97.5%) and higher specificity (85% versus 74%). Empirical therapy was prescribed before the Gram stain result was known in 40 (49%) patients and after in 42 (51%) patients. The antibiotics chosen did not differ between the two groups (P=0.81), nor did they differ for patients with Gram-negative rods on urine Gram stain compared to those with Gram-positive cocci (P=0.67). From these data, we conclude that UA has excellent negative predictive value that is not enhanced by urine Gram stain and that antibiotic selection did not vary based on the urine Gram stain result. In conclusion, the clinical utility of urine Gram stain does not warrant the time or cost it requires. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Gaviria-Agudelo, Claudia; McElvania TeKippe, Erin; Doern, Christopher D.
2015-01-01
Urinary tract infection (UTI) is one of the most common infections in children. Urine culture remains the gold standard for diagnosis, but the utility of urine Gram stain relative to urinalysis (UA) is unclear. We reviewed 312 pediatric patients with suspected UTI who had urine culture, UA, and urine Gram stain performed from a single urine specimen. UA was considered positive if ≥10 leukocytes per oil immersion field were seen or if either nitrates or leukocyte esterase testing was positive. Urine Gram stain was considered positive if any organisms were seen. Sensitivity, specificity, and positive and negative predictive values were calculated using urine culture as the gold standard. Thirty-seven (12%) patients had a culture-proven UTI. Compared to urine Gram stain, UA had equal sensitivity (97.3% versus 97.5%) and higher specificity (85% versus 74%). Empirical therapy was prescribed before the Gram stain result was known in 40 (49%) patients and after in 42 (51%) patients. The antibiotics chosen did not differ between the two groups (P = 0.81), nor did they differ for patients with Gram-negative rods on urine Gram stain compared to those with Gram-positive cocci (P = 0.67). From these data, we conclude that UA has excellent negative predictive value that is not enhanced by urine Gram stain and that antibiotic selection did not vary based on the urine Gram stain result. In conclusion, the clinical utility of urine Gram stain does not warrant the time or cost it requires. PMID:25653411
Lumbiganon, Pisake; Chongsomchai, Chompilas; Chumworathayee, Bundit; Thinkhamrop, Jadsada
2002-08-01
The objective of the study was to assess the diagnostic performance of the reagent strip in screening for asymptomatic bacteriuria in pregnant women using urine culture as a gold standard. This study comprised 204 asymptomatic pregnant women who attended their first antenatal care at Srinagarind Hospital, Khon Kaen University from April 1, 1999 to June 30, 1999. Women with symptoms of urinary tract infection, antibiotic treatment within the previous 7 days, pregnancy-induced hypertension, bleeding per vagina and history of urinary tract diseases were excluded. Urine specimens were collected by clean catched midstream urine technique for urinalysis, reagent strip test and urine culture. Diagnostic performance of reagent strip in terms of sensitivity, specificity, positive and negative predictive value was analyzed. Urine reagent strip test had a sensitivity of 13.9 per cent, a specificity of 95.6 per cent, a positive predictive value of 46.1 per cent, a negative predictive value of 80.6 per cent in detecting asymptomatic bacteriuria in pregnant women.
Standard Specimen Reference Set: Colon — EDRN Public Portal
The Early Detection Research Network, Great Lakes-New England Clinical, Epidemiological and Validation Center (GLNE CVC) announces the availability of serum, plasma and urine samples for the early detection for colon cancer and validation studies.
Urine Concentration and Pyuria for Identifying UTI in Infants.
Chaudhari, Pradip P; Monuteaux, Michael C; Bachur, Richard G
2016-11-01
Varying urine white blood cell (WBC) thresholds have been recommended for the presumptive diagnosis of urinary tract infection (UTI) among young infants. These thresholds have not been studied with newer automated urinalysis systems that analyze uncentrifuged urine that might be influenced by urine concentration. Our objective was to determine the optimal urine WBC threshold for UTI in young infants by using an automated urinalysis system, stratified by urine concentration. Retrospective cross-sectional study of infants aged <3 months evaluated for UTI in the emergency department with paired urinalysis and urine culture. UTI was defined as ≥50 000 colony-forming units/mL from catheterized specimens. Test characteristics were calculated across a range of WBC and leukocyte esterase (LE) cut-points, dichotomized into specific gravity groups (dilute <1.015; concentrated ≥1.015). Twenty-seven thousand infants with a median age of 1.7 months were studied. UTI prevalence was 7.8%. Optimal WBC cut-points were 3 WBC/high-power field (HPF) in dilute urine (likelihood ratio positive [LR+] 9.9, likelihood ratio negative [LR‒] 0.15) and 6 WBC/HPF (LR+ 10.1, LR‒ 0.17) in concentrated urine. For dipstick analysis, positive LE has excellent test characteristics regardless of urine concentration (LR+ 22.1, LR‒ 0.12 in dilute urine; LR+ 31.6, LR‒ 0.22 in concentrated urine). Urine concentration should be incorporated into the interpretation of automated microscopic urinalysis in young infants. Pyuria thresholds of 3 WBC/HPF in dilute urine and 6 WBC/HPF in concentrated urine are recommended for the presumptive diagnosis of UTI. Without correction of specific gravity, positive LE by automated dipstick is a reliably strong indicator of UTI. Copyright © 2016 by the American Academy of Pediatrics.
Oral fluid vs. Urine Analysis to Monitor Synthetic Cannabinoids and Classic Drugs Recent Exposure
Blandino, Vincent; Wetzel, Jillian; Kim, Jiyoung; Haxhi, Petrit; Curtis, Richard; Concheiro, Marta
2018-01-01
Background Urine is a common biological sample to monitor recent drug exposure, and oral fluid is an alternative matrix of increasing interest in clinical and forensic toxicology. Limited data are available about oral fluid vs. urine drug disposition, especially for synthetic cannabinoids. Objective To compare urine and oral fluid as biological matrices to monitor recent drug exposure among HIV-infected homeless individuals. Methods Seventy matched urine and oral fluid samples were collected from 13 participants. Cannabis, amphetamines, benzodiazepines, cocaine and opiates were analyzed in urine by the enzyme-multiplied-immunoassay-technique and in oral fluid by liquid chromatography tandem mass spectrometry (LC-MSMS). Eleven synthetic cannabinoids were analyzed in urine and in oral fluid by LC-MSMS. Results Five oral fluid samples were positive for AB-FUBINACA. In urine, 4 samples tested positive for synthetic cannabinoids PB-22, 5-Fluoro-PB-22, AB-FUBINACA, and metabolites UR-144 5-pentanoic acid and UR-144 4-hydroxypentyl. In only one case, oral fluid and urine results matched, both specimens being AB-FUBINACA positive. For cannabis, 40 samples tested positive in urine and 30 in oral fluid (85.7% match). For cocaine, 37 urine and 52 oral fluid samples were positive (75.7% match). Twenty-four urine samples were positive for opiates, and 25 in oral fluid (81.4% match). For benzodiazepines, 23 samples were positive in urine and 25 in oral fluid (85.7% match). Conclusion/Discussion These results offer new information about drugs disposition between urine and oral fluid. Oral fluid is a good alternative matrix to urine for monitoring cannabis, cocaine, opiates and benzodiazepines recent use; however, synthetic cannabinoids showed mixed results. PMID:29173162
Oral Fluid vs. Urine Analysis to Monitor Synthetic Cannabinoids and Classic Drugs Recent Exposure.
Blandino, Vincent; Wetzel, Jillian; Kim, Jiyoung; Haxhi, Petrit; Curtis, Richard; Concheiro, Marta
2017-01-01
Urine is a common biological sample to monitor recent drug exposure, and oral fluid is an alternative matrix of increasing interest in clinical and forensic toxicology. Limited data are available about oral fluid vs. urine drug disposition, especially for synthetic cannabinoids. To compare urine and oral fluid as biological matrices to monitor recent drug exposure among HIV-infected homeless individuals. Seventy matched urine and oral fluid samples were collected from 13 participants. Cannabis, amphetamines, benzodiazepines, cocaine and opiates were analyzed in urine by the enzyme-multipliedimmunoassay- technique and in oral fluid by liquid chromatography tandem mass spectrometry (LCMSMS). Eleven synthetic cannabinoids were analyzed in urine and in oral fluid by LC-MSMS. Five oral fluid samples were positive for AB-FUBINACA. In urine, 4 samples tested positive for synthetic cannabinoids PB-22, 5-Fluoro-PB-22, AB-FUBINACA, and metabolites UR-144 5-pentanoic acid and UR-144 4-hydroxypentyl. In only one case, oral fluid and urine results matched, both specimens being AB-FUBINACA positive. For cannabis, 40 samples tested positive in urine and 30 in oral fluid (85.7% match). For cocaine, 37 urine and 52 oral fluid samples were positive (75.7% match). Twenty-four urine samples were positive for opiates, and 25 in oral fluid (81.4% match). For benzodiazepines, 23 samples were positive in urine and 25 in oral fluid (85.7% match). These results offer new information about drugs disposition between urine and oral fluid. Oral fluid is a good alternative matrix to urine for monitoring cannabis, cocaine, opiates and benzodiazepines recent use; however, synthetic cannabinoids showed mixed results. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
NASA Technical Reports Server (NTRS)
Foucar, Charlie; Goldberg, Leslie; Hon, Bodin; Moore, Shannon; Williams, Evan
2009-01-01
The impact of bone loss due to different mechanical loadings in microgravity is a major concern for astronauts upon reintroduction to gravitational forces in exploration missions to the Moon and Mars. it has been shown that astronauts not only lose bone at differing rates, with levels up to 2% per month, but each astronaut will respond to bone loss treatments differently. Pre- and post-flight imaging techniques and frozen urine samples for post-flight laboratory immunoassays To develop a novel, non-invasive, highly . sensitive, portable, intuitive, and low-powered device to measure bone resorption levels in 'real time' to provide rapid and Individualized feedback to maximize the efficacy of bone loss countermeasures 1. Collect urine specimen and analyze the level of bone resorption marker, DPD (deoxypridinoline) excreted. 2. Antibodies specific to DPD conjugated with nanoshells and mixed with specimen, the change in absorbance from agglutination is measured by an optical device. 3. The concentration of DPD is displayed and recorded on a PDA
Ling, G V; Franti, C E; Johnson, D L; Ruby, A L
1998-05-01
To compile and analyze selected data from a large number of canine urinary calculus specimens that were subjected to quantitative, layer-by-layer mineral analysis. 11,000 canine urinary calculus specimens: 5,781 from female dogs, 5,215 from male dogs, and 4 from dogs of unrecorded sex. Records of the Urinary Stone Analysis Laboratory, School of Veterinary Medicine, University of California were used to compile information regarding urinary calculus specimens from dogs. Records surveyed were of all canine calculi submitted for analysis between July 1981 and January 1994. Results analyzed included those of a mixed-breed group and 26 common breeds of stone-forming dogs. Interrelations of breed, sex, and age of the affected dogs, mineral composition of the specimens, and associated urinary tract infections were analyzed statistically. Proportions of culture-positive specimens were significantly correlated between the sexes (r = 0.494, P = 0.008). Staphylococcus intermedius was isolated most often from either sex, ranging from 36.1% (Basset Hounds) to 67.9% (Pekingese) of cultured specimens from females and 8.7% (Chihuahuas) to 71.4% (Scottish Terriers) of specimens from males. The second most frequently isolated bacterial species, Escherichia coli, ranged from 0% in males of 2 breeds and females of 4 breeds to 25% in Cairn Terrier males and 19.4% in Basset Hound females. Streptococcus spp were the third most frequently isolated bacterial species. Significant correlations between the sexes were found for percentages of calculi located in the urinary bladder (r = 0.490, P = 0.008), and for calculi voided in the urine (r = 0.503, P = 0.006). Breed and sex differences in prevalence of urolithiasis- and mineral-associated bacterial infections are numerous. Staphylococcus intermedius was the most common isolate from specimens from all but 3 of 54 breed/sex groupings. For either sex, streptococcal infections were significantly related to proportions of calculi passed in the urine.
Smith, Michael L.; Nichols, Daniel C.; Underwood, Paula; Fuller, Zachary; Moser, Matthew A.; Flegel, Ron; Gorelick, David A.; Newmeyer, Matthew N.; Concheiro, Marta; Huestis, Marilyn A.
2014-01-01
Legitimate use of legal intranasal decongestants containing l-methamphetamine may complicate interpretation of urine drug tests positive for amphetamines. Our study hypotheses were that commonly used immunoassays would produce no false-positive results and a recently developed enantiomer-specific gas chromatography–mass spectrometry (GC–MS) procedure would find no d-amphetamine or d-methamphetamine in urine following controlled Vicks VapoInhaler administration at manufacturer's recommended doses. To evaluate these hypotheses, 22 healthy adults were each administered one dose (two inhalations in each nostril) of a Vicks VapoInhaler every 2 h for 10 h on Day 1 (six doses), followed by a single dose on Day 2. Every urine specimen was collected as an individual void for 32 h after the first dose and assayed for d- and l-amphetamines specific isomers with a GC–MS method with >99% purity of R-(−)-α-methoxy-α-(trifluoromethyl)phenylacetyl derivatives and 10 µg/L lower limits of quantification. No d-methamphetamine or d-amphetamine was detected in any urine specimen by GC–MS. The median l-methamphetamine maximum concentration was 62.8 µg/L (range: 11.0–1,440). Only two subjects had detectable l-amphetamine, with maximum concentrations coinciding with l-methamphetamine peak levels, and always ≤4% of the parent's maximum. Three commercial immunoassays for amphetamines EMIT® II Plus, KIMS® II and DRI® had sensitivities, specificities and efficiencies of 100, 97.8, 97.8; 100, 99.6, 99.6 and 100, 100, 100%, respectively. The immunoassays had high efficiencies, but our first hypothesis was not affirmed. The EMIT® II Plus assay produced 2.2% false-positive results, requiring an enantiomer-specific confirmation. PMID:25217541
Screening for the synthetic cannabinoid JWH-018 and its major metabolites in human doping controls.
Möller, Ines; Wintermeyer, Annette; Bender, Katja; Jübner, Martin; Thomas, Andreas; Krug, Oliver; Schänzer, Wilhelm; Thevis, Mario
2011-09-01
Referred to as 'spice', several new drugs, advertised as herbal blends, have appeared on the market in the last few years, in which the synthetic cannabinoids JWH-018 and a C(8) homologue of CP 47,497 were identified as major active ingredients. Due to their reported cannabis-like effects, many European countries have banned these substances. The World Anti-Doping Agency has also explicitly prohibited synthetic cannabinoids in elite sport in-competition. Since urine specimens have been the preferred doping control samples, the elucidation of the metabolic pathways of these substances is of particular importance to implement them in sports drug testing programmes. In a recent report, an in vitro phase-I metabolism study of JWH-018 was presented yielding mainly hydroxylated and N-dealkylated metabolites. Due to these findings, a urine sample of a healthy man declaring to have smoked a 'spice' product was screened for potential phase-I and -II metabolites by high-resolution/high-accuracy mass spectrometry in the present report. The majority of the phase-I metabolites observed in earlier in vitro studies of JWH-018 were detected in this urine specimen and furthermore most of their respective monoglucuronides. As no intact JWH-018 was detectable, the monohydroxylated metabolite being the most abundant one was chosen as a target analyte for sports drug testing purposes; a detection method was subsequently developed and validated in accordance to conventional screening protocols based on enzymatic hydrolysis, liquid-liquid extraction, and liquid chromatography/electrospray tandem mass spectrometry analysis. The method was applied to approximately 7500 urine doping control samples yielding two JWH-018 findings and demonstrated its capability for a sensitive and selective identification of JWH-018 and its metabolites in human urine. Copyright © 2010 John Wiley & Sons, Ltd.
Jang, Moonhee; Kim, Jihyun; Han, Inhoi; Yang, Wonkyung
2015-11-10
Lysergic acid diethylamide (LSD) is administered in low dosages, which makes its detection in biological matrices a major challenge in forensic toxicology. In this study, two sensitive and reliable methods based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) were established and validated for the simultaneous determination of LSD and its metabolite, 2-oxo-3-hydroxy-LSD (O-H-LSD), in hair and urine. Target analytes in hair were extracted using methanol at 38°C for 15h and analyzed by LC-MS/MS. For urine sample preparation, liquid-liquid extraction was performed. Limits of detection (LODs) in hair were 0.25pg/mg for LSD and 0.5pg/mg for O-H-LSD. In urine, LODs were 0.01 and 0.025ng/ml for LSD and O-H-LSD, respectively. Method validation results showed good linearity and acceptable precision and accuracy. The developed methods were applied to authentic specimens from two legal cases of LSD ingestion, and allowed identification and quantification of LSD and O-H-LSD in the specimens. In the two cases, LSD concentrations in hair were 1.27 and 0.95pg/mg; O-H-LSD was detected in one case, but its concentration was below the limit of quantification. In urine samples collected from the two suspects 8 and 3h after ingestion, LSD concentrations were 0.48 and 2.70ng/ml, respectively, while O-H-LSD concentrations were 4.19 and 25.2ng/ml, respectively. These methods can be used for documenting LSD intake in clinical and forensic settings. Copyright © 2015 Elsevier B.V. All rights reserved.
A Preliminary Study of Biomonitoring for Bisphenol-A in Human Sweat.
Porucznik, Christina A; Cox, Kyley J; Wilkins, Diana G; Anderson, David J; Bailey, Nicole M; Szczotka, Kathryn M; Stanford, Joseph B
2015-09-01
Measurement of human exposure to the endocrine disruptor bisphenol-A (BPA) is hampered by the ubiquitous but transient exposure for most individuals, coupled with a short metabolic half-life which leads to high inter- and intra-individual variability. We investigated the possibility of measuring multiday exposure to BPA in human sweat among volunteer participants with the goal of identifying an exposure assessment method less affected by temporal variability. We recruited 50 participants to wear a sweat collection patch (PharmChek(®)) for 7 days with concurrent collection of daily first-morning urine. Urines and sweat patch extracts were analyzed with quantitative LC-MS-MS using a method we previously validated. In addition, a human volunteer consumed one can of commercially available soup (16 oz, 473 cm(3)) daily for 3 days and collected urine. Sweat patches (n = 2, 1 per arm) were worn for the 3 days of the study. BPA was detected in quality control specimens prepared by fortification of BPA to sweat patches, but was only detected at 5× above average background on three participant patches. Although the highest measured urine BPA concentration was 195 ng/mL for an individual with deliberate exposure, no BPA was detected above background in the corresponding sweat patches. In this preliminary investigation, the use of sweat patches primarily worn on the upper-outer arm did not detect BPA exposures that were documented by urine monitoring. The absence of BPA in sweat patches may be due to several factors, including insufficient quantity of specimen per patch, or extremely low concentrations of BPA in naturally occurring sweat, among others. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
NASROLAHEI, M.; VAHEDI, M.; MALEKI, I.
2013-01-01
Summary Objective. Urinary tract infections (UTIs) are amongst the most common infections and account for large proportion of antibacterial drug consumption. The aim of this study was to determine the rate and the etiologic agents of UTIs in inhabitants of rehabilitation centers of Mazandaran province in northern Iran and to evaluate the antimicrobial susceptibility patterns of the uropathogens isolated. Methods. Clean catch midstream urine sample was collected from each of 314 participants (163 males, 151 females) residing in 12 rehabilitation centers of Ramsar, Nowshahr, Chalous, Amol, Sari and Behshahr. Urine specimens were cultured and bacterial isolates were identified by conventional methods. All urines fulfilling the criteria for the presence of significant bacteriuria (≥104 cfu / ml urine) were defined as positive. Antibiotic susceptibility testing was performed by Kirby-Bauer disc diffusion method. Results. The rate of urinary tract infection was 30.9% with the highest rate in pediatrics (p < 0.0001).The prevalence of UTIs were shown to be higher in females than in males with the rate of 46.3% in young aged females (20-29 years), 60% in middle aged group (40-49 years) and 50% in elderly (> 50 years). Bacteria most frequently isolated from urine specimens was Escherichia coli (39.2%) with the highest rate of infection in females age group < 10 years (p < 0.001). Among the antibiotics tested against the isolated organisms for susceptibility test, ceftriaxone and gentamicin maintain good activity against the majority of gram negative bacteria that cause UTIs recovered from individuals with intellectual disability. Vancomycin was effective against Staphylococcus aureus. Conclusions. This survey shows that the prevalence of UTIs among inhabitants of institutions for mentally retarded persons in Mazandaran province of Iran is much higher than normal population. PMID:24783897
Nasrolahei, M; Poorhagibagher, M; Vahedi, M; Maleki, I
2013-09-01
OBJECTIVE. Urinary tract infections (UTIs) are amongst the most common infections and account for large proportion of antibacterial drug consumption. The aim of this study was to determine the rate and the etiologic agents of UTIs in inhabitants of rehabilitation centers of Mazandaran province in northern Iran and to evaluate the antimicrobial susceptibility patterns of the uropathogens isolated. Clean catch midstream urine sample was collected from each of 314 participants (163 males, 151 females) residing in 12 rehabilitation centers of Ramsar, Nowshahr, Chalous, Amol, Sari and Behshahr. Urine specimens were cultured and bacterial isolates were identified by conventional methods. All urines fulfilling the criteria for the presence of significant bacteriuria (> or = 10(4) cfu/ml urine) were defined as positive. Antibiotic susceptibility testing was performed by Kirby-Bauer disc diffusion method. The rate of urinary tract infection was 30.9% with the highest rate in pediatrics (p < 0.0001).The prevalence of UTIs were shown to be higher in females than in males with the rate of 46.3% in young aged females (20-29 years), 60% in middle aged group (40-49 years) and 50% in elderly (> 50 years). Bacteria most frequently isolated from urine specimens was Escherichia coli (39.2%) with the highest rate of infection in females age group < 10 years (p < 0.001). Among the antibiotics tested against the isolated organisms for susceptibility test, ceftriaxone and gentamicin maintain good activity against the majority of gram negative bacteria that cause UTIs recovered from individuals with intellectual disability. Vancomycin was effective against Staphylococcus aureus. This survey shows that the prevalence of UTIs among inhabitants of institutions for mentally retarded persons in Mazandaran province of Iran is much higher than normal population.
Zika Virus Shedding in Semen of Symptomatic Infected Men.
Mead, Paul S; Duggal, Nisha K; Hook, Sarah A; Delorey, Mark; Fischer, Marc; Olzenak McGuire, Dana; Becksted, Heidi; Max, Ryan J; Anishchenko, Michael; Schwartz, Amy M; Tzeng, Wen-Pin; Nelson, Christina A; McDonald, Erin M; Brooks, John T; Brault, Aaron C; Hinckley, Alison F
2018-04-12
Zika virus (ZIKV) is an emerging mosquito-borne flavivirus that has been linked to adverse birth outcomes. Previous reports have shown that person-to-person transmission can occur by means of sexual contact. We conducted a prospective study involving men with symptomatic ZIKV infection to determine the frequency and duration of ZIKV shedding in semen and urine and to identify risk factors for prolonged shedding in these fluids. Specimens were obtained twice per month for 6 months after illness onset and were tested by real-time reverse-transcriptase-polymerase-chain-reaction (RT-PCR) assay for ZIKV RNA and by Vero cell culture and plaque assay for infectious ZIKV. A total of 1327 semen samples from 184 men and 1038 urine samples from 183 men were obtained 14 to 304 days after illness onset. ZIKV RNA was detected in the urine of 7 men (4%) and in the semen of 60 (33%), including in semen samples from 22 of 36 men (61%) who were tested within 30 days after illness onset. ZIKV RNA shedding in semen decreased substantially during the 3 months after illness onset but continued for 281 days in 1 man (1%). Factors that were independently associated with prolonged RNA shedding included older age, less frequent ejaculation, and the presence of certain symptoms at the time of initial illness. Infectious ZIKV was isolated from 3 of 78 semen samples with detectable ZIKV RNA, all obtained within 30 days after illness onset and all with at least 7.0 log 10 ZIKV RNA copies per milliliter of semen. ZIKV RNA was commonly present in the semen of men with symptomatic ZIKV infection and persisted in some men for more than 6 months. In contrast, shedding of infectious ZIKV appeared to be much less common and was limited to the first few weeks after illness onset. (Funded by the Centers for Disease Control and Prevention.).
Estimation of HPV prevalence in young women in Scotland; monitoring of future vaccine impact
2013-01-01
Background Estimation of pre-immunisation prevalence of HPV and distribution of HPV types is fundamental to understanding the subsequent impact of HPV vaccination. We describe the type specific prevalence of HPV in females aged 20–21 in Scotland who attended or defaulted from cervical screening using three specimen types; from attenders liquid based cytology and from defaulters urine or self-taken swabs. Methods Residual liquid based cytology samples (n = 2148), collected from women aged 20–21 attending for their first smear were genotyped for HPV. A sample (n = 709) from women who had defaulted from screening was also made available for HPV testing through the use of postal testing kits (either urine samples (n = 378) or self-taken swabs (n = 331)). Estimates of prevalence weighted by deprivation, and for the postal testing kit, also by reminder status and specimen type were calculated for each HPV type. The distribution of HPV types were compared between specimen types and the occurrence of multiple high-risk infections examined. The influence of demographic factors on high-risk HPV positivity and multiple infections was examined via logistic regression. Results The prevalence of any HPV in young women aged 20–21 was 32.2% for urine, 39.5% for self-taken swab, and 49.4% for LBC specimens. Infection with vaccine specific types (HPV 16, 18) or those associated with cross-protection (HPV 31, 33, 45, 51) was common. Individuals were more likely to test positive for high-risk HPV if they resided in an area of high deprivation or in a rural area. The overall distribution of HPV types did not vary between defaulters and attenders. Multiple infections occurred in 48.1% of high-risk HPV positive individuals. Excluding vaccine types the most common pairing was HPV 56 and 66. Conclusions Understanding of the pre-immunisation prevalence of HPV in young women puts Scotland in a prime position to assess the early effect of vaccination as the first highly vaccinated cohorts of individuals enter the screening programme. Differences in results with different specimen types must be taken into account when monitoring the impact of vaccination programmes. PMID:24188790
Cox, Kyley J; Porucznik, Christina A; Anderson, David J; Brozek, Eric M; Szczotka, Kathryn M; Bailey, Nicole M; Wilkins, Diana G; Stanford, Joseph B
2016-04-01
Bisphenol A (BPA) is an endocrine disruptor and potential reproductive toxicant, but results of epidemiologic studies have been mixed and have been criticized for inadequate exposure assessment that often relies on a single measurement. Our goal was to describe the distribution of BPA concentrations in serial urinary specimens, assess temporal variability, and provide estimates of exposure classification when randomly selected samples are used to predict average exposure. We collected and analyzed 2,614 urine specimens from 83 Utah couples beginning in 2012. Female participants collected daily first-morning urine specimens during one to two menstrual cycles and male partners collected specimens during the woman's fertile window for each cycle. We measured urinary BPA concentrations and calculated geometric means (GM) for each cycle, characterized the distribution of observed values and temporal variability using intraclass correlation coefficients, and performed surrogate category analyses to determine how well repeat samples could classify exposure. The GM urine BPA concentration was 2.78 ng/mL among males and 2.44 ng/mL among females. BPA had a high degree of variability among both males (ICC = 0.18; 95% CI: 0.11, 0.26) and females (ICC = 0.11; 95% CI: 0.08, 0.16). Based on our more stringent surrogate category analysis, to reach proportions ≥ 0.80 for sensitivity, specificity, and positive predictive value (PPV) among females, 6 and 10 repeat samples for the high and low tertiles, respectively, were required. For the medium tertile, specificity reached 0.87 with 10 repeat samples, but even with 11 samples, sensitivity and PPV did not exceed 0.36. Five repeat samples, among males, yielded sensitivity and PPV values ≥ 0.75 for the high and low tertiles, but, similar to females, classification for the medium tertile was less accurate. Repeated urinary specimens are required to characterize typical BPA exposure. Cox KJ, Porucznik CA, Anderson DJ, Brozek EM, Szczotka KM, Bailey NM, Wilkins DG, Stanford JB. 2016. Exposure classification and temporal variability in urinary bisphenol A concentrations among couples in Utah-the HOPE study. Environ Health Perspect 124:498-506; http://dx.doi.org/10.1289/ehp.1509752.
Estimation of HPV prevalence in young women in Scotland; monitoring of future vaccine impact.
Kavanagh, Kimberley; Sinka, Katy; Cuschieri, Kate; Love, John; Potts, Alison; Pollock, Kevin G J; Cubie, Heather; Donaghy, Martin; Robertson, Chris
2013-11-05
Estimation of pre-immunisation prevalence of HPV and distribution of HPV types is fundamental to understanding the subsequent impact of HPV vaccination. We describe the type specific prevalence of HPV in females aged 20-21 in Scotland who attended or defaulted from cervical screening using three specimen types; from attenders liquid based cytology and from defaulters urine or self-taken swabs. Residual liquid based cytology samples (n = 2148), collected from women aged 20-21 attending for their first smear were genotyped for HPV. A sample (n = 709) from women who had defaulted from screening was also made available for HPV testing through the use of postal testing kits (either urine samples (n = 378) or self-taken swabs (n = 331)). Estimates of prevalence weighted by deprivation, and for the postal testing kit, also by reminder status and specimen type were calculated for each HPV type. The distribution of HPV types were compared between specimen types and the occurrence of multiple high-risk infections examined. The influence of demographic factors on high-risk HPV positivity and multiple infections was examined via logistic regression. The prevalence of any HPV in young women aged 20-21 was 32.2% for urine, 39.5% for self-taken swab, and 49.4% for LBC specimens. Infection with vaccine specific types (HPV 16, 18) or those associated with cross-protection (HPV 31, 33, 45, 51) was common. Individuals were more likely to test positive for high-risk HPV if they resided in an area of high deprivation or in a rural area. The overall distribution of HPV types did not vary between defaulters and attenders. Multiple infections occurred in 48.1% of high-risk HPV positive individuals. Excluding vaccine types the most common pairing was HPV 56 and 66. Understanding of the pre-immunisation prevalence of HPV in young women puts Scotland in a prime position to assess the early effect of vaccination as the first highly vaccinated cohorts of individuals enter the screening programme. Differences in results with different specimen types must be taken into account when monitoring the impact of vaccination programmes.
Dib, Josef; Mongongu, Cynthia; Buisson, Corinne; Molina, Adeline; Schänzer, Wilhelm; Thuss, Uwe; Thevis, Mario
2017-01-01
The development of new therapeutics potentially exhibiting performance-enhancing properties implicates the risk of their misuse by athletes in amateur and elite sports. Such drugs necessitate preventive anti-doping research for consideration in sports drug testing programmes. Hypoxia-inducible factor (HIF) stabilizers represent an emerging class of therapeutics that allows for increasing erythropoiesis in patients. BAY 85-3934 is a novel HIF stabilizer, which is currently undergoing phase-2 clinical trials. Consequently, the comprehensive characterization of BAY 85-3934 and human urinary metabolites as well as the implementation of these analytes into routine doping controls is of great importance. The mass spectrometric behaviour of the HIF stabilizer drug candidate BAY 85-3934 and a glucuronidated metabolite (BAY-348) were characterized by electrospray ionization-(tandem) mass spectrometry (ESI-MS(/MS)) and multiple-stage mass spectrometry (MS n ). Subsequently, two different laboratories established different analytical approaches (one each) enabling urine sample analyses by employing either direct urine injection or solid-phase extraction. The methods were cross-validated for the metabolite BAY-348 that is expected to represent an appropriate target analyte for human urine analysis. Two test methods allowing for the detection of BAY-348 in human urine were applied and cross-validated concerning the validation parameters specificity, linearity, lower limit of detection (LLOD; 1-5 ng/mL), ion suppression/enhancement (up to 78%), intra- and inter-day precision (3-21%), recovery (29-48%), and carryover. By means of ten spiked test urine samples sent blinded to one of the participating laboratories, the fitness-for-purpose of both assays was provided as all specimens were correctly identified applying both testing methods. As no post-administration study samples were available, analyses of authentic urine specimens remain desirable. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Mercadante, Rosa; Polledri, Elisa; Bertazzi, Pier Alberto; Fustinoni, Silvia
2013-10-01
The aim of this work was to evaluate short-term and long-term exposure to terbuthylazine (TBA) in agriculture workers (AW), rural residents (RR), and urban residents (UR) using urine and hair specimens. Twelve AW, 13 RR, and 17 UR were included in the study. Urine spot samples were collected with two different protocols. AW urine samples were collected before the application season (February, U0), at bedtime on the day of TBA application (March-May, U1), and prior to the next shift on the day after TBA application (U2). RR and UR urine samples were collected on any day during the application season (Ue). Hair samples were collected for all subjects before the application season (February, H0) and at the end of the season (June, H1). TBA and its metabolite desethylterbuthylazine (DET) were measured by liquid chromatography coupled with triple quadrupole mass spectrometry detection. DET was exclusively found in urine, while TBA was mostly found in the hair. In the AW, the urinary levels of DET were not detected in the U0 samples, and they increased to median levels of 1.81 and 2.94μg/L in the U1 and U2 samples, respectively (p<0.001). In the RR and UR, DET was not detected in the Ue samples. In the UR, TBA was not detected in the H0 samples, and the median levels of TBA were 0.01ng/mg hair in both the AW and RR. In the H1 samples, the median TBA levels were not detected, 0.01, and 0.08ng/mg hair in the UR, RR, and AW, respectively (p<0.001). Urinary DET and hair TBA are promising candidates for biomonitoring short- and long-term exposure to TBA. The use of this herbicide in agriculture leads to exposure in rural residents. © 2013.
Schwebke, Jane R; Gaydos, C A; Davis, T; Marrazzo, J; Furgerson, D; Taylor, S N; Smith, B; Bachmann, L H; Ackerman, R; Spurrell, T; Ferris, D; Burnham, C A; Reno, H; Lebed, J; Eisenberg, D; Kerndt, P; Philip, S; Jordan, J; Quigley, N
2018-02-01
Trichomoniasis is the most prevalent curable sexually transmitted disease (STD). It has been associated with preterm birth and the acquisition and transmission of HIV. Recently, nucleic acid amplification tests (NAAT) have been FDA cleared in the United States for detection of Trichomonas vaginalis in specimens from both women and men. This study reports the results of a multicenter study recently conducted using the Xpert TV ( T. vaginalis ) assay to test specimens from both men and women. On-demand results were available in as little as 40 min for positive specimens. A total of 1,867 women and 4,791 men were eligible for inclusion in the analysis. In women, the performance of the Xpert TV assay was compared to the patient infected status (PIS) derived from the results of InPouch TV broth culture and Aptima NAAT for T. vaginalis The diagnostic sensitivities and specificities of the Xpert TV assay for the combined female specimens (urine samples, self-collected vaginal swabs, and endocervical swabs) ranged from 99.5 to 100% and 99.4 to 99.9%, respectively. For male urine samples, the diagnostic sensitivity and specificity were 97.2% and 99.9%, respectively, compared to PIS results derived from the results of broth culture for T. vaginalis and bidirectional gene sequencing of amplicons. Excellent performance characteristics were seen using both female and male specimens. The ease of using the Xpert TV assay should result in opportunities for enhanced screening for T. vaginalis in both men and women and, hopefully, improved control of this infection. Copyright © 2018 Schwebke et al.
Ferrero, Giulio; Cordero, Francesca; Tarallo, Sonia; Arigoni, Maddalena; Riccardo, Federica; Gallo, Gaetano; Ronco, Guglielmo; Allasia, Marco; Kulkarni, Neha; Matullo, Giuseppe; Vineis, Paolo; Calogero, Raffaele A; Pardini, Barbara; Naccarati, Alessio
2018-01-09
The role of non-coding RNAs in different biological processes and diseases is continuously expanding. Next-generation sequencing together with the parallel improvement of bioinformatics analyses allows the accurate detection and quantification of an increasing number of RNA species. With the aim of exploring new potential biomarkers for disease classification, a clear overview of the expression levels of common/unique small RNA species among different biospecimens is necessary. However, except for miRNAs in plasma, there are no substantial indications about the pattern of expression of various small RNAs in multiple specimens among healthy humans. By analysing small RNA-sequencing data from 243 samples, we have identified and compared the most abundantly and uniformly expressed miRNAs and non-miRNA species of comparable size with the library preparation in four different specimens (plasma exosomes, stool, urine, and cervical scrapes). Eleven miRNAs were commonly detected among all different specimens while 231 miRNAs were globally unique across them. Classification analysis using these miRNAs provided an accuracy of 99.6% to recognize the sample types. piRNAs and tRNAs were the most represented non-miRNA small RNAs detected in all specimen types that were analysed, particularly in urine samples. With the present data, the most uniformly expressed small RNAs in each sample type were also identified. A signature of small RNAs for each specimen could represent a reference gene set in validation studies by RT-qPCR. Overall, the data reported hereby provide an insight of the constitution of the human miRNome and of other small non-coding RNAs in various specimens of healthy individuals.
Impact of enzymatic and alkaline hydrolysis on CBD concentration in urine.
Bergamaschi, Mateus M; Barnes, Allan; Queiroz, Regina H C; Hurd, Yasmin L; Huestis, Marilyn A
2013-05-01
A sensitive and specific analytical method for cannabidiol (CBD) in urine was needed to define urinary CBD pharmacokinetics after controlled CBD administration, and to confirm compliance with CBD medications including Sativex-a cannabis plant extract containing 1:1 ∆(9)-tetrahydrocannabinol (THC) and CBD. Non-psychoactive CBD has a wide range of therapeutic applications and may also influence psychotropic smoked cannabis effects. Few methods exist for the quantification of CBD excretion in urine, and no data are available for phase II metabolism of CBD to CBD-glucuronide or CBD-sulfate. We optimized the hydrolysis of CBD-glucuronide and/or -sulfate, and developed and validated a GC-MS method for urinary CBD quantification. Solid-phase extraction isolated and concentrated analytes prior to GC-MS. Method validation included overnight hydrolysis (16 h) at 37 °C with 2,500 units β-glucuronidase from Red Abalone. Calibration curves were fit by linear least squares regression with 1/x (2) weighting with linear ranges (r(2) > 0.990) of 2.5-100 ng/mL for non-hydrolyzed CBD and 2.5-500 ng/mL for enzyme-hydrolyzed CBD. Bias was 88.7-105.3 %, imprecision 1.4-6.4 % CV and extraction efficiency 82.5-92.7 % (no hydrolysis) and 34.3-47.0 % (enzyme hydrolysis). Enzyme-hydrolyzed urine specimens exhibited more than a 250-fold CBD concentration increase compared to alkaline and non-hydrolyzed specimens. This method can be applied for urinary CBD quantification and further pharmacokinetics characterization following controlled CBD administration.
Analytical sensitivity of four commonly used hCG point of care devices.
Kamer, Sandy M; Foley, Kevin F; Schmidt, Robert L; Greene, Dina N
2015-04-01
Point of care (POC) hCG assays are often used to rule-out pregnancy and therefore diagnostic sensitivity, especially at low concentrations of hCG, is important. There are very few studies in the literature that seek to verify the claimed analytical sensitivity of hCG POC devices. The analytical sensitivity of four commonly used hCG POC devices (Alere hCG Combo Cassette, ICON 20 hCG, OSOM hCG Combo Test, and Sure-Vue Serum/Urine hCG-STAT) was challenged using urine samples (n=50) selected based on quantitative hCG concentrations. The majority of these specimens (n=40) had an hCG concentration between 20 and 200 U/L. Each specimen/device combination was reviewed by three individuals. Statistical calculations were performed using Stata 12. The analytical sensitivity of the OSOM was significantly lower inferior than that of the other POC devices. There was no significant difference in the sensitivity of the Alere, ICON 20 and Sure-Vue devices. There was no significant difference in the individual interpretation of the hCG POC results. All hCG POC devices evaluated in this study were susceptible to false negative results at low concentrations of urine hCG. Laboratorians and clinicians should be aware that there are limitations when using urine hCG POC devices to rule out early pregnancy. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Knittel, Jessica L; Holler, Justin M; Chmiel, Jeffrey D; Vorce, Shawn P; Magluilo, Joseph; Levine, Barry; Ramos, Gerardo; Bosy, Thomas Z
2016-04-01
Synthetic cannabinoids emerged on the designer drug market in recent years due to their ability to produce cannabis-like effects without the risk of detection by traditional drug testing techniques such as immunoassay and gas chromatography-mass spectrometry. As government agencies work to schedule existing synthetic cannabinoids, new, unregulated and structurally diverse compounds continue to be developed and sold. Synthetic cannabinoids undergo extensive metabolic conversion. Consequently, both blood and urine specimens may play an important role in the forensic analysis of synthetic cannabinoids. It has been observed that structurally similar synthetic cannabinoids follow common metabolic pathways, which often produce metabolites with similar metabolic transformations. Presented are two validated quantitative methods for extracting and identifying 15 parent synthetic cannabinoids in blood, 17 synthetic cannabinoid metabolites in urine and the qualitative identification of 2 additional parent compounds. The linear range for most synthetic cannabinoid compounds monitored was 0.1-10 ng/mL with the limit of detection between 0.01 and 0.5 ng/mL. Selectivity, specificity, accuracy, precision, recovery and matrix effect were also examined and determined to be acceptable for each compound. The validated methods were used to analyze a compilation of synthetic cannabinoid investigative cases where both blood and urine specimens were submitted. The study suggests a strong correlation between the metabolites detected in urine and the parent compounds found in blood. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Chisholm, Karen M; Aziz, Natali; McDowell, Michal; Guo, Frances P; Srinivas, Nivedita; Benitz, William E; Norton, Mary E; Gutierrez, Kathleen; Folkins, Ann K; Pinsky, Benjamin A
2014-01-01
Cytomegalovirus (CMV) is the most common cause of congenital infection worldwide. Urine viral culture is the standard for CMV diagnosis in neonates and infants. The objectives of this study were to compare the performance of serial paired rapid shell vial cultures (SVC) and routine viral cultures (RVC), and to determine the optimal number of cultures needed to detect positive cases. From 2001 to 2011, all paired CMV SVC and RVC performed on neonates and infants less than 100 days of age were recorded. Testing episodes were defined as sets of cultures performed within 7 days of one another. A total of 1264 neonates and infants underwent 1478 testing episodes; 68 (5.4%) had at least one episode with a positive CMV culture. In episodes where CMV was detected before day 21 of life, the first specimen was positive in 100% (16/16) of cases. When testing occurred after 21 days of life, the first specimen was positive in 82.7% (43/52) of cases, requiring three cultures to reach 100% detection. The SVC was more prone to assay failure than RVC. Overall, when RVC was compared to SVC, there was 86.0% positive agreement and 99.9% negative agreement. In conclusion, three serial urine samples are necessary for detection of CMV in specimens collected between day of life 22 and 99, while one sample may be sufficient on or before day of life 21. Though SVC was more sensitive than RVC, the risk of SVC failure supports the use of multimodality testing to optimize detection.
Biggerstaff, Brad J.; Tanner, Nathan A.; Lauterbach, Molly; Lanciotti, Robert S.
2017-01-01
Zika virus (ZIKV) has emerged as a major global public health concern in the last two years due to its link as a causative agent of human birth defects. Its rapid expansion into the Western Hemisphere as well as the ability to be transmitted from mother to fetus, through sexual transmission and possibly through blood transfusions has increased the need for a rapid and expansive public health response to this unprecedented epidemic. A non-invasive and rapid ZIKV diagnostic screening assay that can be performed in a clinical setting throughout pregnancy is vital for prenatal care of women living in areas of the world where exposure to the virus is possible. To meet this need we have developed a sensitive and specific reverse transcriptase loop-mediated isothermal amplification (RT-LAMP) assay to detect ZIKV RNA in urine and serum with a simple visual detection. RT-LAMP results were shown to have a limit of detection 10-fold higher than qRT-PCR. As little as 1.2 RNA copies/μl was detected by RT-LAMP from a panel of 178 diagnostic specimens. The assay was shown to be highly specific for ZIKV RNA when tested with diagnostic specimens positive for dengue virus (DENV) and chikungunya virus (CHIKV). The assay described here illustrates the potential for a fast, reliable, sensitive and specific assay for the detection of ZIKV from urine or serum that can be performed in a clinical or field setting with minimal equipment and technological expertise. PMID:28945787
Calvert, Amanda E; Biggerstaff, Brad J; Tanner, Nathan A; Lauterbach, Molly; Lanciotti, Robert S
2017-01-01
Zika virus (ZIKV) has emerged as a major global public health concern in the last two years due to its link as a causative agent of human birth defects. Its rapid expansion into the Western Hemisphere as well as the ability to be transmitted from mother to fetus, through sexual transmission and possibly through blood transfusions has increased the need for a rapid and expansive public health response to this unprecedented epidemic. A non-invasive and rapid ZIKV diagnostic screening assay that can be performed in a clinical setting throughout pregnancy is vital for prenatal care of women living in areas of the world where exposure to the virus is possible. To meet this need we have developed a sensitive and specific reverse transcriptase loop-mediated isothermal amplification (RT-LAMP) assay to detect ZIKV RNA in urine and serum with a simple visual detection. RT-LAMP results were shown to have a limit of detection 10-fold higher than qRT-PCR. As little as 1.2 RNA copies/μl was detected by RT-LAMP from a panel of 178 diagnostic specimens. The assay was shown to be highly specific for ZIKV RNA when tested with diagnostic specimens positive for dengue virus (DENV) and chikungunya virus (CHIKV). The assay described here illustrates the potential for a fast, reliable, sensitive and specific assay for the detection of ZIKV from urine or serum that can be performed in a clinical or field setting with minimal equipment and technological expertise.
Characterization and differentiation of 59 strains of Moraxella urethralis from clinical specimens.
Riley, P S; Hollis, D G; Weaver, R E
1974-09-01
The biochemical characteristics of 59 strains of Moraxella urethralis from clinical specimens, primarily from urine and the female genital tract, were studied. The characteristics included (i) the inability to acidify carbohydrate substrates, (ii) the ability to produce phenylalanine deaminase, (iii) the ability to reduce nitrite, (iv) the lack of urease activity, and (v) the ability of most strains to alkalinize citrate. A means of differentiating M. urethralis from Moraxella osloensis and Moraxella phenylpyruvica was determined.
Bahemia, I A; Muganza, A; Moore, R; Sahid, F; Menezes, C N
2015-11-01
Infections are a major problem in burns patients. Knowledge of the incidence and antimicrobial sensitivities of the microorganisms commonly encountered within each institution's burns unit is important as it informs and directs empiric antibiotic therapy. This was a retrospective review of patients admitted from 1 January 2008 to 31 December 2012 to an adult burns intensive care unit. Specimens chosen for analysis were wound swabs, blood cultures, venous catheter tips, tracheal aspirates, sputum, urine and wound tissue. Records were accessed from the admission register and laboratory information system to obtain the relevant data. During the study period, 352 patients were admitted to the adult burns intensive care unit, of which, 341 patients were included. The mortality rate was 44.6%. Flame burns were the commonest. Mortality rate amongst patients with bacteremia was 46.9%. Acinetobacter baumannii, Pseudomonas aeruginosa and methicillin resistant Staphylococcus aureus (MRSA) were found to be the most common organisms cultured in most specimens. The main three organisms identified in specimen cultures in our adult burns intensive care unit were A. baumannii, P. aeruginosa and MRSA. This study has helped establish a better empiric approach to the management of our septic burns patients. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.
Quantitative mass spectrometry of unconventional human biological matrices
NASA Astrophysics Data System (ADS)
Dutkiewicz, Ewelina P.; Urban, Pawel L.
2016-10-01
The development of sensitive and versatile mass spectrometric methodology has fuelled interest in the analysis of metabolites and drugs in unconventional biological specimens. Here, we discuss the analysis of eight human matrices-hair, nail, breath, saliva, tears, meibum, nasal mucus and skin excretions (including sweat)-by mass spectrometry (MS). The use of such specimens brings a number of advantages, the most important being non-invasive sampling, the limited risk of adulteration and the ability to obtain information that complements blood and urine tests. The most often studied matrices are hair, breath and saliva. This review primarily focuses on endogenous (e.g. potential biomarkers, hormones) and exogenous (e.g. drugs, environmental contaminants) small molecules. The majority of analytical methods used chromatographic separation prior to MS; however, such a hyphenated methodology greatly limits analytical throughput. On the other hand, the mass spectrometric methods that exclude chromatographic separation are fast but suffer from matrix interferences. To enable development of quantitative assays for unconventional matrices, it is desirable to standardize the protocols for the analysis of each specimen and create appropriate certified reference materials. Overcoming these challenges will make analysis of unconventional human biological matrices more common in a clinical setting. This article is part of the themed issue 'Quantitative mass spectrometry'.
The incidence of drugs in fatally injured drivers
DOT National Transportation Integrated Search
1974-02-01
Methods for the collection of blood, urine, bile and alcohol washes of face and fingers from fatally injured drivers have been developed. Specimens were supplied by coroners and medical examiners from fatally injured drivers. Seven hundred and ten we...
The incidence of drugs in fatally injured drivers
DOT National Transportation Integrated Search
1972-09-01
Method for the collection of blood, urine, bile and alcohol washes of face and fingers from fatally injured drivershave been developed. Specimens have been collected ffom Alcohol Safety ALtion Project areas and other cooperating areas. The samples we...
Choi, Hyeyoung; Baeck, Seungkyung; Jang, Moonhee; Lee, Sooyeun; Choi, Hwakyung; Chung, Heesun
2012-02-10
Phenylalkylamine derivatives, such as methamphetamine (MA), amphetamine (AM), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA), phentermine (PT), fenfluramine (FFA) and phenmetrazine (PM), and ketamine (KT) are widely abused recreational or anorectic drugs in Korea and are regulated under the Controlled Substance Act in Korea. Phenylalkylamines and ketamine analysis is normally performed using both urine and hair samples but there is no established method for the simultaneous analysis of all these phenylalkylamines and ketamine in oral fluids. Oral fluid is easy to collect/handle and can provide an indication of recent drug abuse. In this study, to confirm the presence of phenylalkylamine derivatives and ketamine in oral fluid after screening with an immunoassay, an analytical method using automated solid phase extraction (SPE) and gas chromatography-mass spectrometry (GC-MS) was developed and fully validated according to international guidelines. The applicability of the assay was demonstrated by analyzing of authentic oral fluid samples and the results of oral fluid analysis were compared with those in urine and hair to to evaluate the feasibility of oral fluid in forensic cases. The recovery of phenylalkylamines and ketamine from oral fluid collection devices was also assessed. Oral fluid specimens from 23 drug abuse suspects submitted by the police were collected using Salivette (Sarstedt, Nümbrecht, Germany), Quantisal (Immunalysis, Pomona, CA) or direct expectoration. The samples were screened using a biochip array analyzer (Evidence Investigator, Randox, Antrim, UK). For confirmation, the samples were analyzed by GC-MS in selected-ion monitoring (SIM) mode after extraction using automated SPE (RapidTrace, Zymark, MA, USA) with a mixed-mode cation exchange cartridge (CLEAN SCREEN, 130 mg/3 ml, UCT, PA, USA) and derivatization with trifluoroacetic anhydride (TFA). The results from the immunoassay were consistent with those from GC-MS. Twenty oral fluid samples gave positive results for MA, AM, PT and/or PM among the 23 cases, which gave positive results in urine and/or hair. Although large variations in the MA, AM, PT and PM concentrations were observed in three different specimens, the oral fluid specimen was useful for demonstrating phenylalkylamines and ketamine abuse as an alternative specimen for urine. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Sklerov, J H; Kalasinsky, K S; Ehorn, C A
1999-10-01
A confirmatory method for the detection and quantitation of lysergic acid diethylamide (LSD) is presented. The method employs gas chromatography-tandem mass spectrometry (GC-MS-MS) using an internal ionization ion trap detector for sensitive MS-MS-in-time measurements of LSD extracted from urine. Following a single-step solid-phase extraction of 5 mL of urine, underivatized LSD can be measured with limits of quantitation and detection of 80 and 20 pg/mL, respectively. Temperature-programmed on-column injections of urine extracts were linear over the concentration range 20-2000 pg/mL (r2 = 0.999). Intraday and interday coefficients of variation were < 6% and < 13%, respectively. This procedure has been applied to quality-control specimens and LSD-positive samples in this laboratory. Comparisons with alternate GC-MS methods and extraction procedures are discussed.
Dipstick measurements of urine specific gravity are unreliable.
de Buys Roessingh, A S; Drukker, A; Guignard, J P
2001-08-01
To evaluate the reliability of dipstick measurements of urine specific gravity (U-SG). Fresh urine specimens were tested for urine pH and osmolality (U-pH, U-Osm) by a pH meter and an osmometer, and for U-SG by three different methods (refractometry, automatic readout of a dipstick (Clinitek-50), and (visual) change of colour of the dipstick). The correlations between the visual U-SG dipstick measurements and U-SG determined by a refractometer and the comparison of Clinitek((R))-50 dipstick U-SG measurements with U-Osm were less than optimal, showing very wide scatter of values. Only the U-SG refractometer values and U-Osm had a good linear correlation. The tested dipstick was unreliable for the bedside determination of U-SG, even after correction for U-pH, as recommended by the manufacturer. Among the bedside determinations, only refractometry gives reliable U-SG results. Dipstick U-SG measurements should be abandoned.
Aung, Ei T; Fairley, Christopher K; Tabrizi, Sepehr N; Danielewski, Jennifer A; Ong, Jason J; Chen, Marcus Y; Bradshaw, Catriona S; Chow, Eric P F
2017-09-02
Human papillomavirus (HPV) surveillance is important to monitor the effectiveness of national HPV vaccination programmes. Positivity of HPV in urine in men varies with different sampling methods. We aimed to determine the positivity for detection of HPV-6/11 in urine samples among men in relation to the position of genital warts and circumcision status. We analysed stored chlamydia-positive urine specimens in young heterosexual men aged less than 25 years attending Melbourne Sexual Health Centre, Australia, between 2004 and 2015, for HPV genotypes. Positivity of HPV-6/11 and high-risk genotypes were stratified according to the position of genital warts and circumcision status. Positivity of HPV-6/11 was calculated using diagnosis of warts as the gold standard. Warts were classified as proximal penile warts from suprapubic area to midshaft of penis, and distal penile warts from distal shaft of penis to meatus. Of the 934 specimens, 253 (27.1%) men were positive for any HPV and 82 men (8.8%) had genital warts. The ORs of HPV-6/11 detection in urine were 4.63 (95% CI: 1.68 to 12.78) and 40.20 (95% CI: 19.78 to 81.70) times higher among men who had proximal penile warts and distal penile warts, respectively, compared with men who did not have genital warts. Circumcised men were less likely to have high-risk HPV (OR 0.31; 95% CI: 0.14 to 0.65) than uncircumcised men. Uncircumcised men were more likely to have distal penile warts than circumcised men (OR 8.22; 95% CI: 1.34 to 337.46). Positivity of HPV-6/11 in urine increases greatly in men with distal penile warts. Circumcised men are less likely to have distal penile warts, any HPV or high-risk HPV detected. Urine is likely to be an alternative sampling method for HPV-6/11 surveillance programme in men in countries with low circumcision rates. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Ultrastructure of selected struvite-containing urinary calculi from cats.
Neumann, R D; Ruby, A L; Ling, G V; Schiffman, P S; Johnson, D L
1996-01-01
To elucidate the ultrastructural details of struvite-containing urinary calculi from cats. Specimens studied were inclusive of the range of textures visible during preliminary analysis by use of a stereoscopic dissecting microscope. Textural types, which were used to infer crystal growth conditions, were differentiated with regard to crystal habit, crystal size, growth orientation, and primary porosity. Thirty specimens were selected from a collection of approximately 1,600 feline urinary calculi: 20 of these were composed entirely of struvite, and 10 consisted of struvite and calcium phosphate (apatite). Qualitative and quantitative analyses of specimens included use of plain and polarized light microscopy, x-ray diffractometry, scanning electron microscopy with backscattered electron imagery, x-ray fluorescence scans, and electron probe microanalysis. Four textural types were recognized among struvite calculi, whereas 2 textural types of struvite-apatite calculi were described. The presence of minute, well interconnected primary pores in struvite-containing urinary calculi from cats is an important feature, which may promote possible interaction of calculi with changes in urine composition. Primary porosity, which can facilitate interaction between the calculus and changing urine composition, may explain the efficacy of dietary or medicinal manipulations to promote the dissolution of struvite-containing uroliths from this species.
Identification of Unique Metabolites of the Designer Opioid Furanyl Fentanyl.
Goggin, Melissa M; Nguyen, An; Janis, Gregory C
2017-06-01
The illicit drug market has seen an increase in designer opioids, including fentanyl and methadone analogs, and other structurally unrelated opioid agonists. The designer opioid, furanyl fentanyl, is one of many fentanyl analogs clandestinely synthesized for recreational use and contributing to the fentanyl and opioid crisis. A method has been developed and validated for the analysis of furanyl fentanyl and furanyl norfentanyl in urine specimens from pain management programs. Approximately 10% of samples from a set of 500 presumptive heroin-positive urine specimens were found to contain furanyl fentanyl, with an average concentration of 33.8 ng/mL, and ranging from 0.26 to 390 ng/mL. Little to no furanyl norfentanyl was observed; therefore, the furanyl fentanyl specimens were further analyzed by untargeted high-resolution mass spectrometry to identify other metabolites. Multiple metabolites, including a dihydrodiol metabolite, 4-anilino-N-phenethyl-piperidine (4-ANPP) and a sulfate metabolite were identified. The aim of the presented study was to identify the major metabolite(s) of furanyl fentanyl and estimate their concentrations for the purpose of toxicological monitoring. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Chang, Chih-Chun; Su, Ming-Jang; Ho, Jung-Li; Tsai, Yu-Hui; Tsai, Wei-Ting; Lee, Shu-Jene; Yen, Tzung-Hai; Chu, Fang-Yeh
2016-01-01
Urine protein detection could be underestimated using the conventional dipstick method because of variations in urine aliquots. This study aimed to assess the efficacy of the semi-quantitative urine protein-to-creatinine (P/C) ratio compared with other laboratory methods. Random urine samples were requested from patients undergoing chronic kidney disease screening. Significant proteinuria was determined by the quantitative P/C ratio of at least 150 mg protein/g creatinine. The semi-quantitative P/C ratio, dipstick protein and quantitative protein concentrations were compared and analyzed. In the 2932 urine aliquots, 156 (5.3 %) urine samples were considered as diluted and 60 (39.2 %) were found as significant proteinuria. The semi-quantitative P/C ratio testing had the best sensitivity (70.0 %) and specificity (95.9 %) as well as the lowest underestimation rate (0.37 %) when compared to other laboratory methods in the study. In the semi-quantitative P/C ratio test, 19 (12.2 %) had positive, 52 (33.3 %) had diluted, and 85 (54.5 %) had negative results. Of those with positive results, 7 (36.8 %) were positive detected by traditional dipstick urine protein test, and 9 (47.4 %) were positive detected by quantitative urine protein test. Additionally, of those with diluted results, 25 (48.1 %) had significant proteinuria, and all were assigned as no significant proteinuria by both tests. The semi-quantitative urine P/C ratio is clinically applicable based on its better sensitivity and screening ability for significant proteinuria than other laboratory methods, particularly in diluted urine samples. To establish an effective strategy for CKD prevention, urine protein screening with semi-quantitative P/C ratio could be considered.
Price, Travis K.; Dune, Tanaka; Hilt, Evann E.; Thomas-White, Krystal J.; Kliethermes, Stephanie; Brincat, Cynthia; Brubaker, Linda; Wolfe, Alan J.
2016-01-01
Enhanced quantitative urine culture (EQUC) detects live microorganisms in the vast majority of urine specimens reported as “no growth” by the standard urine culture protocol. Here, we evaluated an expanded set of EQUC conditions (expanded-spectrum EQUC) to identify an optimal version that provides a more complete description of uropathogens in women experiencing urinary tract infection (UTI)-like symptoms. One hundred fifty adult urogynecology patient-participants were characterized using a self-completed validated UTI symptom assessment (UTISA) questionnaire and asked “Do you feel you have a UTI?” Women responding negatively were recruited into the no-UTI cohort, while women responding affirmatively were recruited into the UTI cohort; the latter cohort was reassessed with the UTISA questionnaire 3 to 7 days later. Baseline catheterized urine samples were plated using both standard urine culture and expanded-spectrum EQUC protocols: standard urine culture inoculated at 1 μl onto 2 agars incubated aerobically; expanded-spectrum EQUC inoculated at three different volumes of urine onto 7 combinations of agars and environments. Compared to expanded-spectrum EQUC, standard urine culture missed 67% of uropathogens overall and 50% in participants with severe urinary symptoms. Thirty-six percent of participants with missed uropathogens reported no symptom resolution after treatment by standard urine culture results. Optimal detection of uropathogens could be achieved using the following: 100 μl of urine plated onto blood (blood agar plate [BAP]), colistin-nalidixic acid (CNA), and MacConkey agars in 5% CO2 for 48 h. This streamlined EQUC protocol achieved 84% uropathogen detection relative to 33% detection by standard urine culture. The streamlined EQUC protocol improves detection of uropathogens that are likely relevant for symptomatic women, giving clinicians the opportunity to receive additional information not currently reported using standard urine culture techniques. PMID:26962083
Forensic applications of desorption electrospray ionisation mass spectrometry (DESI-MS).
Morelato, Marie; Beavis, Alison; Kirkbride, Paul; Roux, Claude
2013-03-10
Desorption electrospray ionisation mass spectrometry (DESI-MS) is an emerging analytical technique that enables in situ mass spectrometric analysis of specimens under ambient conditions. It has been successfully applied to a large range of forensically relevant materials. This review assesses and highlights forensic applications of DESI-MS including the analysis and detection of illicit drugs, explosives, chemical warfare agents, inks and documents, fingermarks, gunshot residues and drugs of abuse in urine and plasma specimens. The minimal specimen preparation required for analysis and the sensitivity of detection achieved offer great advantages, especially in the field of forensic science. Crown Copyright © 2013. Published by Elsevier Ireland Ltd. All rights reserved.
Changes in the fungal autoflora of Apollo astronauts.
Taylor, G R; Henney, M R; Ellis, W L
1973-11-01
Specimens were repeatedly obtained for mycological examination from the skin, throat, urine, and feces of the six astronauts who conducted the Apollo 14 and Apollo 15 lunar exploration missions. Analysis of preflight data demonstrates that the process of severely restricting opportunities from colonization for 3 weeks before flight resulted in a 50% reduction in the number of isolated species. Postflight data indicate that exposure to the space flight environment for up to 2 weeks resulted in an even greater reduction with a relative increase in the potential pathogen Candida albicans. No incidences of microbial shock were observed when crewmembers were quarantined for 16 days after completion of the space flight. Intercrew transfer of particular species could not be demonstrated because most species were not consistently recovered.
Blood pressure, ethnic group, and salt intake in Belize.
Simmons, D
1983-03-01
A total of 1316 individuals were studied in seven villages in Belize, Central America. This represented 92% of the area population aged over 18. Generally, they were members of three ethnic groups--Maya, Spanish, and Creole. The systolic and diastolic IV and V blood pressures were recorded using standardised procedure. Significant differences in blood pressure, weight, and obesity were found between ethnic groups in both sexes, Creoles having higher means than the other groups. Significant relationships with blood pressure were found with obesity, age, and number of children. An early morning urine specimen was obtained from a random 50% of the men, and only in Creoles was there an association between raised blood pressure and sodium/potassium urinary excretion ratio.
Diversity of the midstream urine microbiome in adults with chronic kidney disease.
Kramer, Holly; Kuffel, Gina; Thomas-White, Krystal; Wolfe, Alan J; Vellanki, Kavitha; Leehey, David J; Bansal, Vinod K; Brubaker, Linda; Flanigan, Robert; Koval, Julia; Wadhwa, Anuradha; Zilliox, Michael J
2018-06-01
To examine the characteristics of the midstream urine microbiome in adults with stage 3-5 non-dialysis-dependent chronic kidney disease (CKD). Patients with non-dialysis-dependent CKD (estimated glomerular filtration rate [eGFR] < 60 ml/min/1.73 m 2 ) and diuretic use were recruited from outpatient nephrology clinics. Midstream voided urine specimens were collected using the clean-catch method. The bacterial composition was determined by sequencing the hypervariable (V4) region of the bacterial 16S ribosomal RNA gene. Extraction negative controls (no urine) were included to assess the contribution of extraneous DNA from possible sources of contamination. Midstream urine microbiome diversity was assessed with the inverse Simpson, Chao and Shannon indices. The diversity measures were further examined by demographic characteristics and by comorbidities. The cohort of 41 women and 36 men with detectable bacterial DNA in their urine samples had a mean age of 71.5 years (standard deviation [SD] 7.9) years (range 60-91 years). The majority were white (68.0%) and a substantial minority were African-American (29.3%) The mean eGFR was 27.2 (SD 13.6) ml/min/1.73 m 2 . Most men (72.2%) were circumcised and 16.6% reported a remote history of prostate cancer. Many midstream voided urine specimens were dominated (> 50% reads) by the genera Corynebacterium (n = 11), Staphylococcus (n = 9), Streptococcus (n = 7), Lactobacillus (n = 7), Gardnerella (n = 7), Prevotella (n = 4), Escherichia_Shigella (n = 3), and Enterobacteriaceae (n = 2); the rest lacked a dominant genus. The samples had high levels of diversity, as measured by the inverse Simpson [7.24 (95% CI 6.76, 7.81)], Chao [558.24 (95% CI 381.70, 879.35)], and Shannon indices [2.60 (95% CI 2.51, 2.69)]. Diversity measures were generally higher in participants with urgency urinary incontinence and higher estimated glomerular filtration rate (eGFR). After controlling for demographics and diabetes status, microbiome diversity was significantly associated with estimated eGFR (P < 0.05). The midstream voided urine microbiome of older adults with stage 3-5 non-dialysis-dependent CKD is diverse. Greater microbiome diversity is associated with higher eGFR.
The analysis of benzodiazepines in forensic urine samples.
DOT National Transportation Integrated Search
1996-04-01
The FAA Toxicology and Accident Research Laboratory reports the presence of any drug detected at therapeutic or subtherapeutic levels and the medical condition for which the drug may have been used. Specimens from the pilot of a fatal aviation accide...
Characterization and Differentiation of 59 Strains of Moraxella urethralis from Clinical Specimens
Riley, P. S.; Hollis, D. G.; Weaver, R. E.
1974-01-01
The biochemical characteristics of 59 strains of Moraxella urethralis from clinical specimens, primarily from urine and the female genital tract, were studied. The characteristics included (i) the inability to acidify carbohydrate substrates, (ii) the ability to produce phenylalanine deaminase, (iii) the ability to reduce nitrite, (iv) the lack of urease activity, and (v) the ability of most strains to alkalinize citrate. A means of differentiating M. urethralis from Moraxella osloensis and Moraxella phenylpyruvica was determined. Images PMID:4417557
2002-01-01
compared to culture.70,72 Use of PCR to detect GC has yielded sensitivities between 92-100% and specificities ranging from 96-99% on endocervical...specimen.73,74 With use of urine specimens, PCR has yielded sensitivities ranging from 65 to 92% and 96-99% respectively, for GC detection .74...21 An important limitation of PCR and LCR is that the tests may detect CT or GC nucleic acid remaining after therapy has been administered
Lindan, Christina; Mathur, Meenakshi; Kumta, Sameer; Jerajani, Hermangi; Gogate, Alka; Schachter, Julius; Moncada, Jeanne
2005-04-01
Pooling urogenital specimens for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae by nucleic acid amplification tests is an attractive alternative to individual testing. As pooling can reduce the costs of testing as well as labor, it has been advocated for use in resource-poor settings. However, it has neither been widely adopted nor evaluated for use in developing countries. We evaluated the practical use of pooling first-catch urine (FCU) specimens for the detection of C. trachomatis and N. gonorrhoeae from 690 men in Mumbai, India, by PCR. FCU, urethral smears, and swabs were collected from men seen at two sexually transmitted infection (STI) clinics. All laboratory testing was done at the Lokmanya Tilak General Hospital. Gram stain smears and culture isolation for N. gonorrhoeae were performed. Each FCU was tested individually and in pools using the Roche Amplicor PCR for C. trachomatis and N. gonorrhoeae with an internal control for inhibition. Specimen pools consisted of aliquots from five consecutively processed FCUs combined into an amplification tube. An optical density reading of > or =0.20 indicated a pool for which subsequent testing of individual samples was required. Prevalence by PCR on single specimens was 2.2% (15/690) for C. trachomatis and 5.4% (37/690) for N. gonorrhoeae. Compared to individual FCU results, pooling for C. trachomatis and N. gonorrhoeae had an overall sensitivity of 96.1% (50/52). Specificity was 96.5% (83/86) in that three pools required single testing that failed to identify a positive specimen. Pooling missed two positive specimens, decreased the inhibition rate, and saved 50.3% of reagent costs. In this resource-limited setting, the use of pooling to detect C. trachomatis and N. gonorrhoeae by PCR proved to be a simple, accurate, and cost-effective procedure compared to individual testing.
Fidani, Marco; Casagni, Eleonora; Montana, Marco; Pasello, Emanuela; Pecoraro, Chiara; Gambaro, Veniero
2006-01-01
Bacteria frequently found in equine urine samples may cause degradation of 17beta-OH steroids. A simple liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed to evaluate the microbiological contamination of equine urine as a marker of poor storage conditions. Norethandrolone was used as the internal standard, and the linearity, sensitivity, precision and accuracy of the method were evaluated. 17beta-OH oxidation was demonstrated for testosterone, nandrolone, trenbolone and boldenone, but did not occur in alpha-epimers such as alpha-boldenone and epitestosterone, demonstrating the stereoselectivity of the reaction. A rapid test was performed by spiking one of the four 17beta-OH steroids in samples of diluted equine urine. The steroids were transformed into their respective ketones in the presence of bacterial activity. The test allows direct injection of diluted samples into the LC/MS system, without the need for prior extraction. Results show that the best method of storage is freezing at -18 degrees C. Urine specimens should be analyzed as soon as possible after thawing. This allows bacterial degradation of equine urine to be arrested temporarily, so that the urine can be used for qualitative or quantitative analysis of 17beta-OH steroids.
Characterization of ultrafiltration of undiluted and diluted stored urine.
Ouma, J; Septien, S; Velkushanova, K; Pocock, J; Buckley, C
2016-11-01
Urine ultrafiltration (UF) was studied in terms of flux, permeability, resistance and fouling. Two types of samples were used: stored urine representing the feedstock obtained from urine diversion dry toilets; and diluted stored urine representing the feedstock obtained from urinals. Three different filtration experiment sets were adopted in this study. For the first case, pressure was set in an ascending order, i.e. from 10 to 60 kPa during filtration of stored urine. For the second case, pressure was set in a descending order, i.e. from 60 to 10 kPa for the same feed stream. The third case involved filtration of diluted urine with pressure in ascending order, i.e. from 10 to 60 kPa. The results indicated that diluted urine had higher flux than undiluted urine with maximum values of 43 and 26 L·m -2 ·h -1 respectively. Cake formation was the dominating fouling mechanism during urine filtration with a contribution of about 90% to the total hydraulic resistance. The contribution of chemically irreversible fouling was low (-2%), unless operating from high to low pressures. Indeed, irreversible fouling appeared to be greater during the experiments starting at higher pressure. Although undiluted urine had a higher fouling potential compared to diluted urine, the specific cake resistance was higher for diluted urine, probably due to a denser cake caused by lower particle sizes in that sample. The permeate obtained after urine filtration had much lower suspended solids content compared to the feedstock, with rejections up to 99%. The concentration of the ionic species remained unchanged, and 75% of the organic compounds and dissolved solids remained in the permeate. Urine UF could then be used as pre-treatment to remove suspended solids.
Evaluating an alternative method for rapid urinary creatinine determination
Creatinine (CR) is an endogenously-produced chemical routinely assayed in urine specimens to assess kidney function, sample dilution. The industry-standard method for CR determination, known as the kinetic Jaffe (KJ) method, relies on an exponential rate of a colorimetric change,...
Automatic bio-sample bacteria detection system
NASA Technical Reports Server (NTRS)
Chappelle, E. W.; Colburn, M.; Kelbaugh, B. N.; Picciolo, G. L.
1971-01-01
Electromechanical device analyzes urine specimens in 15 minutes and processes one sample per minute. Instrument utilizes bioluminescent reaction between luciferase-luciferin mixture and adenosine triphosphate (ATP) to determine number of bacteria present in the sample. Device has potential application to analysis of other body fluids.
Microbiological test results using three urine pretreatment regimes with 316L stainless steel
NASA Technical Reports Server (NTRS)
Huff, Timothy L.
1993-01-01
Three urine pretreatments, (1) Oxone (Dupont) and sulfuric acid, (2) sodium hypochlorite and sulfuric acid, (3) and ozone, were studied for their ability to reduce microbial levels in urine and minimize surface attachment to 316L stainless steel coupons. Urine samples inoculated with Bacillus insolitus and a filamentous mold, organisms previously recovered from the vapor compression distillation subsystem of NASA Space Station Freedom water recovery test were tested in glass corrosion cells containing base or weld metal coupons. Microbial levels, changes in pH, color, turbidity, and odor of the fluid were monitored over the course of the 21-day test. Specimen surfaces were examined by scanning electron microscopy at completion of the test for microbial attachment. Ozonated urine samples were less turbid and had lower microbial levels than controls or samples receiving other pretreatments. Base metal coupons receiving pretreatment were relatively free of attached bacteria. However, well-developed biofilms were found in the heat-affected regions of welded coupons receiving Oxone and hypochlorite pretreatments. Few bacteria were observed in the same regions of the ozone pretreatment sample.
Essig, Andreas; von Baum, Heike; Gonser, Theodor; Haerter, Georg; Lück, Christian
2016-02-01
An explosive outbreak of Legionnaires' disease with 64 reported cases occurred in Ulm/Neu-Ulm in the South of Germany in December 2009/January 2010 caused by Legionella (L.) pneumophila serogroup 1, monoclonal (mAb) subtype Knoxville, sequence type (ST) 62. Here we present the clinical microbiological results from 51 patients who were diagnosed at the University hospital of Ulm, the results of the environmental investigations and of molecular typing of patients and environmental strains. All 50 patients from whom urine specimens were available were positive for L. pneumophila antigen when an enzyme-linked immunosorbent assay (EIA) was used following concentration of those urine samples that tested initially negative. The sensitivity of the BinaxNow rapid immunographic assay (ICA), after 15 min reading and after 60 min reading were 70% and 84%, respectively. Direct typing confirmed the monoclonal subtype Knoxville in 5 out of 8 concentrated urine samples. Real time PCR testing of respiratory tract specimens for L. pneumophila was positive in 15 out of 25 (60%) patients. Direct nested sequence based typing (nSBT) in some of these samples allowed partial confirmation of ST62. L. pneumophila serogroup 1, monoclonal subtype Knoxville ST62, defined as the epidemic strain was isolated from 8 out of 31 outbreak patients (26%) and from one cooling tower confirming it as the most likely source of the outbreak. While rapid detection of Legionella antigenuria was crucial for the recognition and management of the outbreak, culture and molecular typing of the strains from patients and environmental specimens was the clue for the rapid identification of the source of infection. Copyright © 2016 Elsevier GmbH. All rights reserved.
Frazee, Bradley W; Enriquez, Kayla; Ng, Valerie; Alter, Harrison
2015-06-01
Voided urinalysis to test for urinary tract infection (UTI) is prone to false-positive results for a number of reasons. Specimens are often collected at triage from women with any abdominal complaint, creating a low UTI prevalence population. Improper collection technique by the patient may affect the result. At least four indices, if positive, can indicate UTI. We examine the impact of voided specimen collection technique on urinalysis indicators of UTI and on urine culture contamination in disease-free women. In this crossover design, 40 menstrual-age female emergency department staff without UTI symptoms collected urine two ways: directly in a cup ("non-clean") and midstream clean catch ("ideal"). Samples underwent standard automated urinalysis and culture. Urinalysis indices and culture contamination were compared. The proportion of abnormal results from samples collected by "non-clean" vs. "ideal" technique, respectively, were: leukocyte esterase (>trace) 50%, 35% (95% confidence interval for difference -6% to 36%); nitrites (any) 2.5%, 2.5% (difference -2.5 to 2.5%); white blood cells (>5/high-powered field [HPF]) 50%, 27.5% (difference 4 to 41%); bacteria (any/HPF) 77.5%, 62.5%, (difference -7 to 37%); epithelial cells (>few) 65%, 30% (difference 13 to 56%); culture contamination (>1000 colony-forming units of commensal or >2 species) 77%, 63% (difference -5 to 35%). No urinalysis index was positively correlated with culture contamination. Contemporary automated urinalysis indices were often abnormal in a disease-free population of women, even using ideal collection technique. In clinical practice, such false-positive results could lead to false-positive UTI diagnosis. Only urine nitrite showed a high specificity. Culture contamination was common regardless of collection technique and was not predicted by urinalysis results. Copyright © 2015 Elsevier Inc. All rights reserved.
Ironmonger, Dean; Edeghere, Obaghe; Gossain, Savita; Hawkey, Peter M
2016-05-24
There is a marked variation in both antibiotic prescribing practice and urine sampling rates for diagnostic microbiology across general practices in England. To help understand factors driving this variation, we undertook a survey in 2012/13 to determine sampling protocols and antibiotic formularies used by general practitioners (GPs) for managing urinary tract infections (UTIs) in the West Midlands region of England. Cross-sectional survey of all eligible general practices in the West Midlands region of England undertaken in November 2012. GPs were invited to complete an online survey questionnaire to gather information on policies used within the practice for urine sampling for microbiological examination, and the source of antibiotic formularies used to guide treatment of UTIs. The questionnaire also gathered information on how they would manage five hypothetical clinical scenarios encountered in the community. The response rate was 11.3 % (409/3635 GPs), equivalent to a practice response rate of 26 % (248/950). Only 50 % of GPs reported having a practice policy for urine sampling. Although there was good agreement from GPs regarding collecting specimens in scenarios symbolising treatment failure (98 %), UTI in an adult male (98 %) and asymptomatic UTI in pregnancy (97 %), there was variation in GPs requesting a specimen for the scenarios involving a suspected uncomplicated urinary tract infection (UTI) and an asymptomatic catheterised elderly patient; with 40 and 38 % respectively indicating they would collect a specimen for microbiological examination. Standardised evidence based clinical management policies and antibiotic formularies for GPs should be readily available. This will promote the rational use of diagnostic microbiology services, improve antimicrobial stewardship and aid the interpretation of ongoing antimicrobial resistance surveillance.
Porucznik, Christina A; Cox, Kyley J; Schliep, Karen C; Wilkins, Diana G; Stanford, Joseph B
2016-06-08
To examine transient environmental exposures and their relationship with human fecundity, exposure assessment should occur optimally at the time of conception in both members of the couple. We performed an observational, prospective cohort study with biomonitoring in both members of a heterosexual couple trying to conceive. Couples collected urine, saliva, and semen specimens for up to two menstrual cycles on days corresponding to the time windows of fertilization, implantation, and early pregnancy, identified based on the woman's observations of her cervical fluid. Three hundred nine eligible couples were screened between 2011 and 2015, of which 183 enrolled. Eleven couples (6.0 %) withdrew or were lost to follow up. The most successful and cost effective recruiting strategies were word of mouth (40 % of participating couples), posters and flyers (37 %), and targeted Facebook advertising (13 %) with an overall investment of $37.35 spent on recruitment per couple. Both men and women collected ≥97.2 % of requested saliva samples, and men collected ≥89.9 % of requested semen samples. Within the periovulatory days (±3 days), there was at least one urine specimen collected by women in 97.1 % of cycles, and at least one by men in 91.7 % of cycles. Daily compliance with periovulatory urine specimens ranged from 66.5 to 92.4 % for women and from 55.7 to 75.0 % for men. Compliance was ≥88 % for questionnaire completion at specified time points. Couples planning to conceive can be recruited successfully for periconceptional monitoring, and will comply with intensive study protocols involving home collection of biospecimens and questionnaire data.
Genc, Ozlem; Aksu, Evrim
2018-05-01
Our goal was to compare a rapid test (OXA-48K-SeT) and four different chromogenic media (CHROMagar KPC, CHROMagar mSuperCARBA, ChromID Carba and ChromID OXA-48) for the detection of OXA-48 producing Klebsiella pneumoniae isolates and spiked urine/blood samples with these bacteria. In total 100 K.pneumoniae isolates, including 60 OXA-48 positive, 15 other carbapenemase producing, 15 Extended spectrum betalactamases (ESBL) positive and 10 carbapenem sensitive K.pneumoniae were included in the study. After all samples were inoculated into all chromogenic media, temocillin discs were placed onto the media. OXA-48K-SeT was studied according to the manufacturer's instructions and the lower detection limit was determined. Sensitivities and specificities of all chromogenic media and rapid test were detected as 100%. All of the OXA-48 producers were found resistant to temocillin on all chromogenic media. The lower detection limit of the rapid assay was determined as 10 6 in both direct bacterial samples and in spiked urine/blood samples. As a result, four chromogenic culture media and OXA-48 K-SeT can be used safely for detection of OXA-48 positive K.pneumoniae isolates. Although direct clinical specimens were not used, our study suggests that this media and OXA-48 K-SeT may be used in patient samples like blood and urine. Further studies are needed to assess this suggestion. Copyright © 2018 Elsevier B.V. All rights reserved.
Impact of enzymatic and alkaline hydrolysis on CBD concentration in urine
Bergamaschi, Mateus M.; Barnes, Allan; Queiroz, Regina H. C.; Hurd, Yasmin L.
2013-01-01
A sensitive and specific analytical method for cannabidiol (CBD) in urine was needed to define urinary CBD pharmacokinetics after controlled CBD administration, and to confirm compliance with CBD medications including Sativex—a cannabis plant extract containing 1:1 Δ9-tetrahydrocannabinol (THC) and CBD. Non-psychoactive CBD has a wide range of therapeutic applications and may also influence psychotropic smoked cannabis effects. Few methods exist for the quantification of CBD excretion in urine, and no data are available for phase II metabolism of CBD to CBD-glucuronide or CBD-sulfate. We optimized the hydrolysis of CBD-glucuronide and/or -sulfate, and developed and validated a GC-MS method for urinary CBD quantification. Solid-phase extraction isolated and concentrated analytes prior to GC-MS. Method validation included overnight hydrolysis (16 h) at 37 °C with 2,500 units β-glucuronidase from Red Abalone. Calibration curves were fit by linear least squares regression with 1/x2 weighting with linear ranges (r2>0.990) of 2.5–100 ng/mL for non-hydrolyzed CBD and 2.5–500 ng/mL for enzyme-hydrolyzed CBD. Bias was 88.7–105.3 %, imprecision 1.4–6.4 % CV and extraction efficiency 82.5–92.7 % (no hydrolysis) and 34.3–47.0 % (enzyme hydrolysis). Enzyme-hydrolyzed urine specimens exhibited more than a 250-fold CBD concentration increase compared to alkaline and non-hydrolyzed specimens. This method can be applied for urinary CBD quantification and further pharmacokinetics characterization following controlled CBD administration. PMID:23494274
Abraham, Tsadik T.; Lowe, Ross H.; Pirnay, Stephane O.; Darwin, William D.; Huesti, Marilyn A.
2009-01-01
A sensitive and specific method for extraction and quantification of Δ9-tetrahydrocannabinol (THC), 11-hydroxy-Δ9-tetrahydrocannabinol (11-OH-THC), and 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THCCOOH) in human urine was developed and fully validated. To ensure complete hydrolysis of conjugates and capture of total analyte content, urine samples were hydrolyzed by two methods in series. Initial hydrolysis was with Escherichia coli β-glucuronidase (Type IX–A) followed by a second hydrolysis utilizing 10N NaOH. Specimens were adjusted to pH 5−6.5, treated with acetonitrile to precipitate protein, and centrifuged, and the supernatants were subjected to solid-phase extraction. Extracted analytes were derivatized with BSTFA and quantified by gas chromatography–mass spectrometry with electron impact ionization. Standard curves were linear from 2.5 to 300 ng/mL. Extraction efficiencies were 57.0−59.3% for THC, 68.3−75.5% for 11-OH-THC, and 71.5−79.7% for THCCOOH. Intra- and interassay precision across the linear range of the assay ranged from 0.1 to 4.3% and 2.6 to 7.4%, respectively. Accuracy was within 15% of target concentrations. This method was applied to the analysis of urine specimens collected from individuals participating in controlled administration cannabis studies, and it may be a useful analytical procedure for determining recency of cannabis use in forensic toxicology applications. PMID:17988462
Simplified urinary immunoassay for 2,4-D: validation and exposure assessment.
Lyubimov, A V; Garry, V F; Carlson, R E; Barr, D B; Baker, S E
2000-08-01
Urinary monitoring of exposed workers by either analytic chemical methods or radioimmunoassay suggests that urinary levels of 2,4-dichlorophenoxyacetic acid (2,4-D) exceeding 30 ppb are indicative of occupational exposure. However, the current methods do not lend themselves to clinical laboratory use in the rural medical setting. The major goal of this project was to provide medical practitioners who care for members of the agricultural community with a cost-efficient way to conduct exposure assessment. This project used a direct 2,4-D enzyme immunoassay (EIA) and measurement of the ratio between 2,4-D-spiked and non-spiked samples of the same urine to quantify 2,4-D levels. This simplified approach minimizes the effects of non-specific interfering substances in urine and eliminates the need for sample extraction and clean-up. Possible urine co-contaminants (2,4-dichlorophenol and 2,5-dichlorophenol) do not significantly interfere with this immunoassay. Twenty-two forest pesticide applicators who apply and use chlorophenoxy herbicides in their work and 14 comparable control subjects were studied to validate the assay in the occupational setting. Coded urine specimens were examined for levels of 2,4-D by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) and compared with immunoassay results from the same specimens. A correlation coefficient of r = 0.982 with a P value of .0001 for a plot of HPLC-MS/MS versus immunoassay demonstrated that the results from these methods were comparable over urinary dose levels ranging from not detectable (<19 ppb) to 1700 ppb 2,4-D, as determined by immunoassay.
Quantifying cobalt in doping control urine samples--a pilot study.
Krug, Oliver; Kutscher, Daniel; Piper, Thomas; Geyer, Hans; Schänzer, Wilhelm; Thevis, Mario
2014-01-01
Since first reports on the impact of metals such as manganese and cobalt on erythropoiesis were published in the late 1920s, cobaltous chloride became a viable though not widespread means for the treatment of anaemic conditions. Today, its use is de facto eliminated from clinical practice; however, its (mis)use in human as well as animal sport as an erythropoiesis-stimulating agent has been discussed frequently. In order to assess possible analytical options and to provide relevant information on the prevalence of cobalt use/misuse among athletes, urinary cobalt concentrations were determined by inductively coupled plasma-mass spectrometry (ICP-MS) from four groups of subjects. The cohorts consisted of (1) a reference population with specimens of 100 non-elite athletes (not being part of the doping control system), (2) a total of 96 doping control samples from endurance sport athletes, (3) elimination study urine samples collected from six individuals having ingested cobaltous chloride (500 µg/day) through dietary supplements, and (4) samples from people supplementing vitamin B12 (cobalamin) at 500 µg/day, accounting for approximately 22 µg of cobalt. The obtained results demonstrated that urinary cobalt concentrations of the reference population as well as the group of elite athletes were within normal ranges (0.1-2.2 ng/mL). A modest but significant difference between these two groups was observed (Wilcoxon rank sum test, p < 0.01) with the athletes' samples presenting slightly higher urinary cobalt levels. The elimination study urine specimens yielded cobalt concentrations between 40 and 318 ng/mL during the first 6 h post-administration, and levels remained elevated (>22 ng/mL) up to 33 h. Oral supplementation of 500 µg of cobalamin did not result in urinary cobalt concentrations > 2 ng/mL. Based on these pilot study data it is concluded that measuring the urinary concentration of cobalt can provide information indicating the use of cobaltous chloride by athletes. Additional studies are however required to elucidate further factors potentially influencing urinary cobalt levels. Copyright © 2014 John Wiley & Sons, Ltd.
Lin, Na; Ye, Jun; Qiu, Wenjuan; Han, Lianshu; Zhang, Huiwen; Gu, Xuefan
2013-01-01
Maple syrup urine disease (MSUD) is an inherited disorder caused by a deficiency of the mitochondrial branched-chain keto acid dehydrogenase complex. We investigated whether liquid chromatography-tandem mass spectrometry (LC-MS/MS) is a more reliable and accurate method than MS/MS in the diagnosis and management of patients with MSUD in a Chinese population. A total of 370 dried blood spots (DBS) from healthy neonates, 44 DBS specimens from phenylketonuria neonates, and 38 DBS samples from 10 MSUD patients were retrospectively tested using the LC-MS/MS method. The results were compared with those obtained by the MS/MS method. The reference intervals of branched-chain amino acids (BCAAs) and alloiosleucine (Allo-Ile) were estimated for both sexes. In classic MSUD patients, Allo-Ile was markedly elevated (average of 136 μmol/L, which was significantly higher than the normal value, <5 μmol/L). The averages of BCAAs were also markedly elevated continually during the treatment. The application of the LC-MS/MS method in the measurement of Allo-Ile and BCAAs in DBS is more useful for diagnosing and managing classic MSUD than the MS/MS method.
Johnson, J S; Croall, J; Power, J S; Armstrong, G R
1998-10-01
Serratia marcescens is commonly isolated from the urine of patients with an indwelling urinary catheter and in the absence of symptoms is often regarded as a contaminant. A case of fatal Serratia marcescens septicaemia with meningitis, brain abscesses, and myocarditis discovered at necropsy is described. The patient was an 83 year old man with an indwelling urinary catheter who suffered from several chronic medical conditions and from whose urine Serratia marcescens was isolated at the time of catheterisation. Serratia marcescens can be a virulent pathogen in particular groups of patients and when assessing its significance in catheter urine specimens, consideration should be given to recognised risk factors such as old age, previous antibiotic treatment, and underlying chronic or debilitating disease, even in the absence of clinical symptoms.
Comparison of Inoculation with the InoqulA and WASP Automated Systems with Manual Inoculation
Croxatto, Antony; Dijkstra, Klaas; Prod'hom, Guy
2015-01-01
The quality of sample inoculation is critical for achieving an optimal yield of discrete colonies in both monomicrobial and polymicrobial samples to perform identification and antibiotic susceptibility testing. Consequently, we compared the performance between the InoqulA (BD Kiestra), the WASP (Copan), and manual inoculation methods. Defined mono- and polymicrobial samples of 4 bacterial species and cloudy urine specimens were inoculated on chromogenic agar by the InoqulA, the WASP, and manual methods. Images taken with ImagA (BD Kiestra) were analyzed with the VisionLab version 3.43 image analysis software to assess the quality of growth and to prevent subjective interpretation of the data. A 3- to 10-fold higher yield of discrete colonies was observed following automated inoculation with both the InoqulA and WASP systems than that with manual inoculation. The difference in performance between automated and manual inoculation was mainly observed at concentrations of >106 bacteria/ml. Inoculation with the InoqulA system allowed us to obtain significantly more discrete colonies than the WASP system at concentrations of >107 bacteria/ml. However, the level of difference observed was bacterial species dependent. Discrete colonies of bacteria present in 100- to 1,000-fold lower concentrations than the most concentrated populations in defined polymicrobial samples were not reproducibly recovered, even with the automated systems. The analysis of cloudy urine specimens showed that InoqulA inoculation provided a statistically significantly higher number of discrete colonies than that with WASP and manual inoculation. Consequently, the automated InoqulA inoculation greatly decreased the requirement for bacterial subculture and thus resulted in a significant reduction in the time to results, laboratory workload, and laboratory costs. PMID:25972424
Heffernan, A L; English, K; Toms, Lml; Calafat, A M; Valentin-Blasini, L; Hobson, P; Broomhall, S; Ware, R S; Jagals, P; Sly, P D; Mueller, J F
2016-12-01
A range of pesticides are available in Australia for use in agricultural and domestic settings to control pests, including organophosphate and pyrethroid insecticides, herbicides, and insect repellents, such as N,N-diethyl-meta-toluamide (DEET). The aim of this study was to provide a cost-effective preliminary assessment of background exposure to a range of pesticides among a convenience sample of Australian residents. De-identified urine specimens stratified by age and sex were obtained from a community-based pathology laboratory and pooled (n = 24 pools of 100 specimens). Concentrations of urinary pesticide biomarkers were quantified using solid-phase extraction coupled with isotope dilution high-performance liquid chromatography-tandem mass spectrometry. Geometric mean biomarker concentrations ranged from <0.1 to 36.8 ng/mL for organophosphate insecticides, <0.1 to 5.5 ng/mL for pyrethroid insecticides, and <0.1 to 8.51 ng/mL for all other biomarkers with the exception of the DEET metabolite 3-diethylcarbamoyl benzoic acid (4.23 to 850 ng/mL). We observed no association between age and concentration for most biomarkers measured but noted a "U-shaped" trend for five organophosphate metabolites, with the highest concentrations observed in the youngest and oldest age strata, perhaps related to age-specific differences in behavior or physiology. The fact that concentrations of specific and non-specific metabolites of the organophosphate insecticide chlorpyrifos were higher than reported in USA and Canada may relate to differences in registered applications among countries. Additional biomonitoring programs of the general population and focusing on vulnerable populations would improve the exposure assessment and the monitoring of temporal exposure trends as usage patterns of pesticide products in Australia change over time.
Kapala, J.; Copes, D.; Sproston, A.; Patel, J.; Jang, D.; Petrich, A.; Mahony, J.; Biers, K.; Chernesky, M.
2000-01-01
Specimen pooling to achieve efficiency when testing urine specimens for Chlamydia trachomatis nucleic acids has been suggested. We pooled endocervical swabs from 1,288 women and also tested individual swabs by ligase chain reaction (LCR). Out of 53 positive specimens, pools of 4 or 8 specimens missed two positives, providing 96.2% accuracy compared to individual test results. Dilution and positive-control spiking experiments showed that negative specimens with inhibitors of LCR in the pool reduced the signal. Conversely, two extra positives, detected only through pooling, were negative by individual testing but became positive after storage, suggesting that fresh positive specimens with labile inhibitors may be positive in a pool because of dilution of inhibitors. For this population of women with a 4% prevalence of C. trachomatis infection, substantial savings in cost of reagents (55 to 63%) and technologist time (50 to 63%) made pooling strategies a desirable alternative to individual testing. PMID:10878029
42 CFR 493.911 - Bacteriology.
Code of Federal Regulations, 2010 CFR
2010-10-01
... identify aerobic bacteria from throat, urine, cervical, or urethral discharge specimens to the genus level... bacteria from any source to the species level and may also perform antimicrobial susceptibility tests; and... anaerobic bacteria from any source. (b) Program content and frequency of challenge. To be approved for...
42 CFR 493.911 - Bacteriology.
Code of Federal Regulations, 2011 CFR
2011-10-01
... identify aerobic bacteria from throat, urine, cervical, or urethral discharge specimens to the genus level... bacteria from any source to the species level and may also perform antimicrobial susceptibility tests; and... anaerobic bacteria from any source. (b) Program content and frequency of challenge. To be approved for...
Code of Federal Regulations, 2011 CFR
2011-01-01
... retrieval of all information pertaining to the individual urine specimens for a minimum period of five years... disclosure of such information shall be followed. Moreover, owing to DOE's express environmental, public..., DOE must be kept fully apprised of all aspects of the contractor's program, including such information...
Code of Federal Regulations, 2012 CFR
2012-01-01
... retrieval of all information pertaining to the individual urine specimens for a minimum period of five years... disclosure of such information shall be followed. Moreover, owing to DOE's express environmental, public..., DOE must be kept fully apprised of all aspects of the contractor's program, including such information...
Jones, Jefferson; Klein, Ron; Popescu, Saskia; Rose, Karen; Kretschmer, Melissa; Carrigan, Alice; Trembath, Felicia; Koski, Lia; Zabel, Karen; Ostdiek, Scott; Rowell-Kinnard, Paula; Munoz, Esther; Sunenshine, Rebecca; Sylvester, Tammy
2015-08-07
On January 23, 2015, the Maricopa County Department of Public Health (MCDPH) was notified of a suspected measles case in a nurse, a woman aged 48 years. On January 11, the nurse had contact with a patient with laboratory-confirmed measles associated with the Disneyland theme park-related outbreak in California. On January 21, she developed a fever (103°F [39.4°C]), on January 23 she experienced cough and coryza, and on January 24, she developed a rash. The patient was instructed to isolate herself at home. On January 26, serum, a nasopharyngeal swab, and a urine specimen were collected. The following day, measles infection was diagnosed by real time reverse transcription polymerase chain reaction testing of the nasopharyngeal swab and urine specimen and by detection of measles-specific immunoglobulin (Ig)M and IgG in serum by enzyme-linked immunosorbent assay. Because of her symptoms and laboratory results, the patient was considered to be infectious.
Taylor, Darlene; Lunny, Carole; Wong, Tom; Gilbert, Mark; Li, Neville; Lester, Richard; Krajden, Mel; Hoang, Linda; Ogilvie, Gina
2013-10-10
Three meta-analyses and one systematic review have been conducted on the question of whether self-collected specimens are as accurate as clinician-collected specimens for STI screening. However, these reviews predate 2007 and did not analyze rectal or pharyngeal collection sites. Currently, there is no consensus on which sampling method is the most effective for the diagnosis of genital chlamydia (CT), gonorrhea (GC) or human papillomavirus (HPV) infection. Our meta-analysis aims to be comprehensive in that it will examine the evidence of whether self-collected vaginal, urine, pharyngeal and rectal specimens provide as accurate a clinical diagnosis as clinician-collected samples (reference standard). Eligible studies include both randomized and non-randomized controlled trials, pre- and post-test designs, and controlled observational studies. The databases that will be searched include the Cochrane Database of Systematic Reviews, Web of Science, Database of Abstracts of Reviews of Effects (DARE), EMBASE and PubMed/Medline. Data will be abstracted independently by two reviewers using a standardized pre-tested data abstraction form. Heterogeneity will be assessed using the Q2 test. Sensitivity and specificity estimates with 95% confidence intervals as well as negative and positive likelihood ratios will be pooled and weighted using random effects meta-analysis, if appropriate. A hierarchical summary receiver operating characteristics curve for self-collected specimens will be generated. This synthesis involves a meta-analysis of self-collected samples (urine, vaginal, pharyngeal and rectal swabs) versus clinician-collected samples for the diagnosis of CT, GC and HPV, the most prevalent STIs. Our systematic review will allow patients, clinicians and researchers to determine the diagnostic accuracy of specimens collected by patients compared to those collected by clinicians in the detection of chlamydia, gonorrhea and HPV.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cone, E.J.; Johnson, R.E.; Darwin, W.D.
In two separate studies, 5 drug-free male volunteers with a history of marijuana use were passively exposed to the sidestream smoke of 4 and 16 marijuana cigarettes (2.8% delta-9-tetrahydrocannabinol (THC)) for 1 h each day for 6 consecutive days. A third study was similarly performed with 2 marijuana-naive subjects passively exposed to the smoke of 16 marijuana cigarettes. Passive smoke exposure was conducted in a small, unventilated room. Room air levels of THC and CO were monitored frequently. All urine specimens were collected and analyzed by EMIT d.a.u. assay, Abuscreen radioimmunoassay and GC/MS. The studies show that significant amounts ofmore » THC were absorbed by all subjects at the higher level of passive smoke exposure (eg., smoke from 16 marijuana cigarettes), resulting in urinary excretion of significant amounts of cannabinoid metabolites. However, it seems improbable that subjects would unknowingly tolerate the noxious smoke conditions produced by this exposure. At the lower level of passive marijuana-smoke exposure, specimens tested positive only infrequently or were negative. Room air levels of THC during passive smoke exposure appeared to be the most critical factor in determining whether a subject produced cannabinoid-positive urine specimens.« less
Dipstick measurements of urine specific gravity are unreliable
Roessingh, A; Drukker, A; Guignard, J
2001-01-01
AIM—To evaluate the reliability of dipstick measurements of urine specific gravity (U-SG). METHODS—Fresh urine specimens were tested for urine pH and osmolality (U-pH, U-Osm) by a pH meter and an osmometer, and for U-SG by three different methods (refractometry, automatic readout of a dipstick (Clinitek-50), and (visual) change of colour of the dipstick). RESULTS—The correlations between the visual U-SG dipstick measurements and U-SG determined by a refractometer and the comparison of Clinitek®-50 dipstick U-SG measurements with U-Osm were less than optimal, showing very wide scatter of values. Only the U-SG refractometer values and U-Osm had a good linear correlation. The tested dipstick was unreliable for the bedside determination of U-SG, even after correction for U-pH, as recommended by the manufacturer. CONCLUSIONS—Among the bedside determinations, only refractometry gives reliable U-SG results. Dipstick U-SG measurements should be abandoned. PMID:11466191
[Detection of West Nile virus in human samples: follow-up studies during the 2015 seasonal period].
Nagy, Anna; Nagy, Orsolya; Bán, Enikő; Molnár, Eszter; Müller, Zsófia; Orbán, Márton; Kecskés, Borbála; Harsányi, Emese Henriett; Kővágó, Levente; Jobbágy, Lajos; Németh, Zoltán; Várnai, Zsuzsanna; Takács, Mária
2017-05-01
West Nile virus, a mosquito-borne viral zoonosis is responsible for human infections in Hungary. Laboratory diagnosis is based on serological tests, however the application of molecular methods has been appreciated. The aim of the study was to investigate blood, cerebrospinal-fluid and urine samples of acutely ill patients and to follow-up PCR positive cases to ascertain the length of virus excretion. Clinical specimens were examined by indirect-immunofluorescent, haemagglutination-inhibition, two PCR tests and Sanger-sequencing. Virus isolation in case of two patients was successful. A follow-up study could be carried out in case of 5 patients. Viral nucleic acid was detectable in urine even for several weeks after symptom onset and viral RNA was present at higher concentration compared with other samples. PCR analysis of urine could provide useful epidemiological and diagnostic information. Therefore, it is recommended to collect urine samples in order to supplement the serological diagnosis. Orv Hetil. 2017; 158(20): 791-796.
PCA3 Reference Set Application: T2-Erg-Martin Sanda-Emory (2014) — EDRN Public Portal
We hypothesize that combining T2:erg (T2:erg) fusion and PCA3 detection in urine collected after digital rectal exam can improve the specificity of identifying clinically significant prostate cancer presence over the standard PSA and DRE. To address this hypothesis we propose to validate the performance of the urinary T2:erg in a multiplex model predicting the diagnosis of clinically significant prostate cancer on subsequent prostate biopsy using post-DRE pre biopsy urine specimens from a cohort of 900 men on the EDRN’s PCA3 trial.
2014-01-01
This is the first quantitative analysis of data from urine drug tests for compliance to treatment medications and abstinence from drug abuse across “levels of care” in six eastern states of America. Comprehensive Analysis of Reported Drugs (CARD) data was used in this post-hoc retrospective observational study from 10,570 patients, filtered to include a total of 2,919 patients prescribed at least one treatment medication during 2010 and 2011. The first and last urine samples (5,838 specimens) were analyzed; compliance to treatment medications and abstinence from drugs of abuse supported treatment effectiveness for many. Compared to non-compliant patients, compliant patients were marginally less likely to abuse opioids, cannabinoids, and ethanol during treatment although more likely to abuse benzodiazepines. Almost 17% of the non-abstinent patients used benzodiazepines, 15% used opiates, and 10% used cocaine during treatment. Compliance was significantly higher in residential than in the non-residential treatment facilities. Independent of level of care, 67.2% of the patients (n = 1963; P<.001) had every treatment medication found in both first and last urine specimens (compliance). In addition, 39.2% of the patients (n = 1143; P<.001) had no substance of abuse detected in either the first or last urine samples (abstinence). Moreover, in 2010, 16.9% of the patients (n = 57) were abstinent at first but not at last urine (deteriorating abstinence), the percentage dropped to 13.3% (n = 174) in 2011; this improvement over years was statistically significant. A longitudinal analysis for abstinence and compliance was studied in a randomized subset from 2011, (n = 511) representing 17.5% of the total cohort. A statistically significant upward trend (p = 2.353×10−8) of abstinence rates as well as a similar but stronger trend for compliance ((p = 2.200×10−16) was found. Being cognizant of the trend toward drug urine testing being linked to medical necessity eliminating abusive screening, the interpretation of these valuable results require further intensive investigation. PMID:25247439
Health Instruction Packages: Consumer--Self-Examination.
ERIC Educational Resources Information Center
Maas, Carolyn; And Others
These three learning modules present text, illustrations, and exercises to teach lay persons to take and interpret a temperature, collect a urine specimen, and perform a breast examination. The first module, by Carolyn Maas, defines "temperature," describes the three body areas for temperature taking, distinguishes between normal and…
DOT National Transportation Integrated Search
1992-03-01
Aviation medical examiners who are designated to collect urine specimens were surveyed to collect information and assess attitudes about different aspects of the pre-employment and pre-appointment drug testing program. Fifty-seven percent of the samp...
Smith, Michael L; Nichols, Daniel C; Underwood, Paula; Fuller, Zachary; Moser, Matthew A; Flegel, Ron; Gorelick, David A; Newmeyer, Matthew N; Concheiro, Marta; Huestis, Marilyn A
2014-10-01
Legitimate use of legal intranasal decongestants containing l-methamphetamine may complicate interpretation of urine drug tests positive for amphetamines. Our study hypotheses were that commonly used immunoassays would produce no false-positive results and a recently developed enantiomer-specific gas chromatography-mass spectrometry (GC-MS) procedure would find no d-amphetamine or d-methamphetamine in urine following controlled Vicks VapoInhaler administration at manufacturer's recommended doses. To evaluate these hypotheses, 22 healthy adults were each administered one dose (two inhalations in each nostril) of a Vicks VapoInhaler every 2 h for 10 h on Day 1 (six doses), followed by a single dose on Day 2. Every urine specimen was collected as an individual void for 32 h after the first dose and assayed for d- and l-amphetamines specific isomers with a GC-MS method with >99% purity of R-(-)-α-methoxy-α-(trifluoromethyl)phenylacetyl derivatives and 10 µg/L lower limits of quantification. No d-methamphetamine or d-amphetamine was detected in any urine specimen by GC-MS. The median l-methamphetamine maximum concentration was 62.8 µg/L (range: 11.0-1,440). Only two subjects had detectable l-amphetamine, with maximum concentrations coinciding with l-methamphetamine peak levels, and always ≤ 4% of the parent's maximum. Three commercial immunoassays for amphetamines EMIT(®) II Plus, KIMS(®) II and DRI(®) had sensitivities, specificities and efficiencies of 100, 97.8, 97.8; 100, 99.6, 99.6 and 100, 100, 100%, respectively. The immunoassays had high efficiencies, but our first hypothesis was not affirmed. The EMIT(®) II Plus assay produced 2.2% false-positive results, requiring an enantiomer-specific confirmation. Published by Oxford University Press 2014. This work is written by (a) US Government employee(s) and is in the public domain in the US.
Griswold, Matthew K; Chai, Peter R; Krotulski, Alex J; Friscia, Melissa; Chapman, Brittany P; Varma, Neha; Boyer, Edward W; Logan, Barry K; Babu, Kavita M
2017-12-01
The adulteration of heroin with non-pharmaceutical fentanyl and other high-potency opioids is one of the factors contributing to striking increases in overdose deaths. To fully understand the magnitude of this problem, accurate detection methods for fentanyl and other novel opioid adulterant exposures are urgently required. The objective of this work was to compare the detection of fentanyl in oral fluid and urine specimens using liquid chromatography quadrupole time-of-flight mass spectrometry (LC-QTOF-MS) in a population of heroin users presenting to the Emergency Department after overdose. This was a prospective observational study of adult Emergency Department patients who presented after a reported heroin overdose requiring naloxone administration. Participants provided paired oral fluid and urine specimens, which were prepared, extracted, and analyzed using a dual LC-QTOF-MS workflow for the identification of traditional and emerging drugs of abuse. Analytical instrumentation included SCIEX TripleTOF® 5600+ and Waters Xevo® G2-S QTOF systems. Thirty participants (N = 30) were enrolled during the study period. Twenty-nine participants had fentanyl detected in their urine, while 27 had fentanyl identified in their oral fluid (overall agreement 93.3%, positive percent agreement 93.1%). Cohen's Kappa (k) was calculated and demonstrated moderately, significant agreement (k = 0.47; p value 0.002) in fentanyl detection between oral fluid and urine using this LC-QTOF-MS methodology. Additional novel opioids and metabolites, including norfentanyl, acetylfentanyl, and U-47700, were detected during this study. In this study of individuals presenting to the ED after reported heroin overdose, a strikingly high proportion had a detectable fentanyl exposure. Using LC-QTOF-MS, the agreement between paired oral fluid and urine testing for fentanyl detection indicates a role for oral fluid testing in surveillance for nonpharmaceutical fentanyl. Additionally, the use of LC-QTOF-MS allowed for the detection of other clandestine opioids (acetylfentanyl and U-47700) in oral fluid.
Changes in the Fungal Autoflora of Apollo Astronauts
Taylor, Gerald R.; Henney, Mary R.; Ellis, Walter L.
1973-01-01
Specimens were repeatedly obtained for mycological examination from the skin, throat, urine, and feces of the six astronauts who conducted the Apollo 14 and Apollo 15 lunar exploration missions. Analysis of preflight data demonstrates that the process of severely restricting opportunities from colonization for 3 weeks before flight resulted in a 50% reduction in the number of isolated species. Postflight data indicate that exposure to the space flight environment for up to 2 weeks resulted in an even greater reduction with a relative increase in the potential pathogen Candida albicans. No incidences of microbial shock were observed when crewmembers were quarantined for 16 days after completion of the space flight. Intercrew transfer of particular species could not be demonstrated because most species were not consistently recovered. PMID:4762399
Vernillo, Anthony; Welie, Jos V M; Naidoo, Sudeshni; Malamud, Daniel
2011-01-01
Saliva may be a legal and ethical counterpart of other bodily fluids in diagnostic testing to blood and urine, with regard to its role in diagnostic testing. Two paradigms that have been proposed in the literature to address these challenges are reviewed in this paper. The first is centered on ownership and property rights to saliva, including financial compensation from commercially developed products using saliva. The commodification of saliva as property is also discussed. The second paradigm is related to privacy and the potential for genetic discrimination, given the unwarranted disclosure of confidential information. The management of saliva specimens from dental patients and research participants will also require the implementation of innovative approaches to obtain informed consent.
Vu, N T; Chaturvedi, A K; Canfield, D V
1999-05-31
Urine is often the sample of choice for drug screening in aviation/general forensic toxicology and in workplace drug testing. In some instances, the origin of the submitted samples may be challenged because of the medicolegal and socioeconomic consequences of a positive drug test. Methods for individualization of biological samples have reached a new boundary with the application of the polymerase chain reaction (PCR) in DNA profiling, but a successful characterization of the urine specimens depends on the quantity and quality of DNA present in the samples. Therefore, the present study investigated the influence of storage conditions, sample volume, concentration modes, extraction procedures, and chemical preservations on the quantity of DNA recovered, as well as the success rate of PCR-based genotyping for DQA1 and PM loci in urine. Urine specimens from male and female volunteers were divided and stored at various temperatures for up to 30 days. The results suggested that sample purification by dialfiltration, using 3000-100,000 molecular weight cut-off filters, did not enhance DNA recovery and typing rate as compared with simple centrifugation procedures. Extraction of urinary DNA by the organic method and by the resin method gave comparable typing results. Larger sample volume yielded a higher amount of DNA, but the typing rates were not affected for sample volumes between 1 and 5 ml. The quantifiable amounts of DNA present were found to be greater in female (14-200 ng/ml) than in male (4-60 ng/ml) samples and decreased with the elapsed time under both room temperature (RT) and frozen storage. Typing of the male samples also demonstrated that RT storage samples produced significantly higher success rates than that of frozen samples, while there was only marginal difference in the DNA typing rates among the conditions tested using female samples. Successful assignment of DQA1 + PM genotype was achieved for all samples of fresh urine, independent of gender, starting sample volume, or concentration method. Preservation by 0.25% sodium azide was acceptable for sample storage at 4 degrees C during a period of 30 days. For longer storage duration, freezing at -70 degrees C may be more appropriate. Thus, the applicability of the DQA1 + PM typing was clearly demonstrated for individualization of urine samples.
Urine: Waste product or biologically active tissue?
2018-03-01
Historically, urine has been viewed primarily as a waste product with little biological role in the overall health of an individual. Increasingly, data suggest that urine plays a role in human health beyond waste excretion. For example, urine might act as an irritant and contribute to symptoms through interaction with-and potential compromise of-the urothelium. To explore the concept that urine may be a vehicle for agents with potential or occult bioactivity and to discuss existing evidence and novel research questions that may yield insight into such a role, the National Institute of Diabetes and Digestive and Kidney Disease invited experts in the fields of comparative evolutionary physiology, basic science, nephrology, urology, pediatrics, metabolomics, and proteomics (among others) to a Urinology Think Tank meeting on February 9, 2015. This report reflects ideas that evolved from this meeting and current literature, including the concept of urine quality, the biological, chemical, and physical characteristics of urine, including the microbiota, cells, exosomes, pH, metabolites, proteins, and specific gravity (among others). Additionally, the manuscript presents speculative, and hopefully testable, ideas about the functional roles of urine constituents in health and disease. Moving forward, there are several questions that need further understanding and pursuit. There were suggestions to consider actively using various animal models and their biological specimens to elaborate on basic mechanistic information regarding human bladder dysfunction. Published 2018. This article is a U.S. Government work and is in the public domain in the USA.
Workplace drug testing in Italy: findings about second-stage testing.
Vignali, Claudia; Stramesi, Cristiana; Morini, Luca; San Bartolomeo, Paolo; Groppi, Angelo
2015-03-01
Workplace Drug Testing (WDT) in Italy includes two levels of monitoring: a first stage concerning drug testing on urine samples and a second involving both urine and hair analysis. The second stage is performed only on workers who tested positive at the first level. We analyzed urine and hair specimens from 120 workers undergoing second-level testing between 2009 and 2012. Eighty percent of them had tested positive for cannabinoids during the first level analysis, and 15.8% for cocaine. Both urine and hair samples were analyzed in order to find the following drugs of abuse: amphetamines, buprenorphine, cannabinoids, cocaine, ecstasy, methadone, and opiates. Urine analyses were performed by immunological screening (EMIT); urine confirmatory tests and hair analyses were performed by gas chromatography-mass spectrometry (GC-MS). As regards second-stage testing on urine samples, 71.2% of workers were always negative, whereas 23.9% tested positive at least once for cannabinoids and 2.5% for cocaine. Hair analyses produced surprising results: 61.9% of hair samples tested negative, only 6.2% tested positive for cannabinoids, whereas 28.8% tested positive for cocaine. These findings confirm that second-level surveillance of WDT, which includes hair analysis, is very effective because it highlights drug intake - sometimes heavy - that cannot be revealed only through urine analyses. The employees for whom drug addiction is proved can begin rehabilitation, while keeping their job. Eventually, our results confirmed the widespread and undeclared use of cocaine in Italy. Copyright © 2014 John Wiley & Sons, Ltd.
Stability studies of amphetamine and ephedrine derivatives in urine.
Jiménez, C; de la Torre, R; Ventura, M; Segura, J; Ventura, R
2006-10-20
Knowledge of the stability of drugs in biological specimens is a critical consideration for the interpretation of analytical results. Identification of proper storage conditions has been a matter of concern for most toxicology laboratories (both clinical and forensic), and the stability of drugs of abuse has been extensively studied. This concern should be extended to other areas of analytical chemistry like antidoping control. In this work, the stability of ephedrine derivatives (ephedrine, norephedrine, methylephedrine, pseudoephedrine, and norpseudoephedrine), and amphetamine derivatives (amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), and 3,4-methylenedioxymethamphetamine (MDMA)) in urine has been studied. Spiked urine samples were prepared for stability testing. Urine samples were quantified by GC/NPD or GC/MS. The homogeneity of each batch of sample was verified before starting the stability study. The stability of analytes was evaluated in sterilized and non-sterilized urine samples at different storage conditions. For long-term stability testing, analyte concentration in urine stored at 4 degrees C and -20 degrees C was determined at different time intervals for 24 months for sterile urine samples, and for 6 months for non-sterile samples. For short-term stability testing, analyte concentration was evaluated in liquid urine stored at 37 degrees C for 7 days. The effect of repeated freezing (at -20 degrees C) and thawing (at room temperature) was also studied in sterile urine for up to three cycles. No significant loss of the analytes under study was observed at any of the investigated conditions. These results show the feasibility of preparing reference materials containing ephedrine and amphetamine derivatives to be used for quality control purposes.
Objective non-intrusive markers of sperm production and sexual activity
Sivananthan, Thilee; Bathur, Franz; Jimenez, Mark; Conway, Ann; Idan, Amanda; Handelsman, David
2012-01-01
Objective studies of men's reproductive function are hindered by their reliance on: (i) self-reporting to quantify sexual activity and (ii) masturbation to quantify sperm output rendering both types of estimate vulnerable to unverifiable subjective factors. We therefore examined whether detection of spermatozoa and measurement of prostate-specific antigen (PSA) in urine could provide objective semiquantitative estimates of sperm output and recent ejaculation, respectively, using widely available laboratory techniques. Of 11 healthy volunteers who provided urine samples before and at intervals for 5 days after ejaculation, sperm was present in 2/11 men before, and in all 11/11 samples immediately after ejaculation, but by the second and subsequent void, spermatozoa were present in ∼10%. PSA was detectable at high levels in all urine samples, peaking at the first post-ejaculatory sample but returning to baseline levels by the second post-ejaculatory void. We conclude that urinary spermatozoa and PSA are objective biomarkers for sperm production and sexual activity, but only for a short-time window until the first post-ejaculatory urine void. Hence, for a single urine specimen, the presence of spermatozoa and PSA are valid biomarkers, reflecting sperm production and recent ejaculation only until the next micturition, so their measurement should be restricted to the first morning urine void. PMID:22522506
Contamination of dried blood spots - an underestimated risk in newborn screening.
Winter, Theresa; Lange, Anja; Hannemann, Anke; Nauck, Matthias; Müller, Cornelia
2018-01-26
Newborn screening (NBS) is an established screening procedure in many countries worldwide, aiming at the early detection of inborn errors of metabolism. For decades, dried blood spots have been the standard specimen for NBS. The procedure of blood collection is well described and standardized and includes many critical pre-analytical steps. We examined the impact of contamination of some anticipated common substances on NBS results obtained from dry spot samples. This possible pre-analytical source of uncertainty has been poorly examined in the past. Capillary blood was obtained from 15 adult volunteers and applied to 10 screening filter papers per volunteer. Nine filter papers were contaminated without visible trace. The contaminants were baby diaper rash cream, baby wet wipes, disinfectant, liquid infant formula, liquid infant formula hypoallergenic (HA), ultrasonic gel, breast milk, feces, and urine. The differences between control and contaminated samples were evaluated for 45 NBS quantities. We estimated if the contaminations might lead to false-positive NBS results. Eight of nine investigated contaminants significantly altered NBS analyte concentrations and potentially caused false-positive screening outcomes. A contamination with feces was most influential, affecting 24 of 45 tested analytes followed by liquid infant formula (HA) and urine, affecting 19 and 13 of 45 analytes, respectively. A contamination of filter paper samples can have a substantial effect on the NBS results. Our results underline the importance of good pre-analytical training to make the staff aware of the threat and ensure reliable screening results.
Pratap, Chandra Bhan; Kumar, Gopal; Patel, Saurabh Kumar; Shukla, Vijay K; Kumar, Kailash; Singh, Tej Bali
2014-01-01
Introduction: Enteric fever is a systemic disease caused by Salmonella organism such as serotypes Typhi and ParaTyphi A, B, C. Salmonella ParaTyphi A contributes more than 50% of all the enteric fever cases and it has recently been projected as an emerging pathogen. Materials and Methods: The present study was aimed to detect Salmonella Typhi and ParaTyphi A in urine, blood and stool specimens collected from cases of enteric fever (110), chronic typhoid carriers (46) and healthy controls (75) to explore the possibility of mixed infection by nested PCR. A new nested PCR primer was designed targeting putative fimbrial protein (stkG) gene which is one of the fimbrial gene families to Salmonella ParaTyphi A and for S. Typhi already reported primers targeting flagellin (fliC) gene. Results: Large volume of urine specimens (15 ml) was found to be the best for detection of Salmonella serotypes. The urine sample was found to have mixed-infection by both the serotypes in 40.9% of the cases but lower in blood (27.3%) and stool (13.6%). Conclusion: The present study concludes that occurrence of mixed infection may be quite frequent in typhoid and chronic typhoid carriers’ individuals, although the reported recent rise in ParaTyphi A incidence may not be real. PMID:25584217
Llewellyn, L E; Dodd, M J; Robertson, A; Ericson, G; de Koning, C; Negri, A P
2002-10-01
After ingestion of a specimen of the crab Zosimus aeneus (Xanthidae), an East Timorese adult male died within several hours. Xanthid crabs are known to harbour paralytic shellfish toxins (PSTs), tetrodotoxin and palytoxin. A post-mortem examination did not find any obvious pathological abnormalities. This absence of pathologies is more often associated with PSTs and tetrodotoxin intoxication. A second, yet uneaten specimen of Z. aeneus from the same meal, contained a significant amount of PSTs and these same toxins were identified in the gut contents, blood, liver and urine of the victim. Metabolism of the PSTs occurred with the ingested crab harbouring gonyautoxin 2, gonyautoxin 3 and saxitoxin (STX) whereas neoSTX, decarbamoylSTX and STX dominated the PSTs in the victim's urine. The PST composition in the gut contents, in both their identity and proportion, was intermediate between the eaten crab and the urine suggesting that toxin conversion commenced in the victim's gut. The dose consumed by the victim was calculated to be between 1 and 2 microg STX equivalents/kg based upon the concentration in the remains of the cooked crab. The victim's meal did not consist solely of the toxic crab eaten and the possibility of other food items acting in a synergistic manner with the consumed PSTs cannot be discounted. Copyright 2002 Elsevier Science Ltd.
An Advanced Pharmacy Practice Experience in Sports Pharmacy
2008-01-01
Objective To establish and evaluate an advanced pharmacy practice experience (APPE) in sports pharmacy. Design Students actively participated in a variety of activities for this new 6-week elective APPE, including drug-testing collections, delivering presentations, and providing drug information. Students also learned about assays, compounding, and dispensing medications specifically for athletes, and visited various athletic medical facilities. Student were given written and practical certification examinations for drug-testing collections, and their specimen measurements were compared to those obtained by the testing laboratory for validation; satisfaction surveys were obtained from testing sites; and presentation evaluations were obtained from audience participants. Assessment Students were able to accurately measure pH and specific gravity of urine samples and all students passed the certification examination. Students rated the APPE very high. Also, students received high satisfaction ratings on surveys administered to the officials of the schools where they tested and members of the groups to whom they gave presentations. Conclusion Students gained experience and insight into the various roles of pharmacists in sports pharmacy and developed confidence in their ability to conduct drug-testing collections. PMID:18322580
49 CFR 40.73 - How is the collection process completed?
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 1 2013-10-01 2013-10-01 false How is the collection process completed? 40.73 Section 40.73 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.73 How is the collection process...
49 CFR 40.73 - How is the collection process completed?
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 1 2010-10-01 2010-10-01 false How is the collection process completed? 40.73 Section 40.73 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.73 How is the collection process...
49 CFR 40.73 - How is the collection process completed?
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 1 2012-10-01 2012-10-01 false How is the collection process completed? 40.73 Section 40.73 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.73 How is the collection process...
49 CFR 40.73 - How is the collection process completed?
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 1 2014-10-01 2014-10-01 false How is the collection process completed? 40.73 Section 40.73 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.73 How is the collection process...
10 CFR 26.153 - Using certified laboratories for testing urine specimens.
Code of Federal Regulations, 2011 CFR
2011-01-01
... for Substance Abuse Prevention, Substance Abuse and Mental Health Services Administration, Room 815.... 26.153 Section 26.153 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Laboratories... Workplace Drug Testing Programs [published in the Federal Register on April 11, 1988 (53 FR 11970), and as...
10 CFR 26.153 - Using certified laboratories for testing urine specimens.
Code of Federal Regulations, 2012 CFR
2012-01-01
... for Substance Abuse Prevention, Substance Abuse and Mental Health Services Administration, Room 815.... 26.153 Section 26.153 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Laboratories... Workplace Drug Testing Programs [published in the Federal Register on April 11, 1988 (53 FR 11970), and as...
10 CFR 26.153 - Using certified laboratories for testing urine specimens.
Code of Federal Regulations, 2014 CFR
2014-01-01
... for Substance Abuse Prevention, Substance Abuse and Mental Health Services Administration, Room 815.... 26.153 Section 26.153 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Laboratories... Workplace Drug Testing Programs [published in the Federal Register on April 11, 1988 (53 FR 11970), and as...
10 CFR 26.153 - Using certified laboratories for testing urine specimens.
Code of Federal Regulations, 2013 CFR
2013-01-01
... for Substance Abuse Prevention, Substance Abuse and Mental Health Services Administration, Room 815.... 26.153 Section 26.153 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Laboratories... Workplace Drug Testing Programs [published in the Federal Register on April 11, 1988 (53 FR 11970), and as...
10 CFR 26.153 - Using certified laboratories for testing urine specimens.
Code of Federal Regulations, 2010 CFR
2010-01-01
... for Substance Abuse Prevention, Substance Abuse and Mental Health Services Administration, Room 815.... 26.153 Section 26.153 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Laboratories... Workplace Drug Testing Programs [published in the Federal Register on April 11, 1988 (53 FR 11970), and as...
40 CFR 160.190 - Storage and retrieval of records and data.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Storage and retrieval of records and data. 160.190 Section 160.190 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... soil, water, and plants, and wet specimens of blood, urine, feces, and biological fluids, do not need...
Showing Its Colors. Thin-Layer Chromatographic Detection of Cannabinoid Metabolites.
ERIC Educational Resources Information Center
Bonicamp, Judith M.
1986-01-01
Describes a chemistry laboratory experiment in which thin-layer chromatography (TLC) is used to analyze urine specimens containing metabolites of the drug tetrahydro-cannabinol, which comes from the marijuana plant. The materials needed to conduct the experiment are listed, and the procedure and expected results are outlined. (TW)
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-02
... Engage in Urine Drug Testing for Federal Agencies AGENCY: Substance Abuse and Mental Health Services... the standards of the Mandatory Guidelines for Federal Workplace Drug Testing Programs (Mandatory... and Instrumented Initial Testing Facilities (IITF) must meet in order to conduct drug and specimen...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-10
... standards that require the use of the best available technology for ensuring the full reliability and... available technology for ensuring the full reliability and accuracy of urine drug tests, while reflecting..., cutoffs, specimen validity, collection, collection devices, and testing. II. Solicitation of Comments: As...
Urinary Amino Acid Analysis: A Comparison of iTRAQ®-LC-MS/MS, GC-MS, and Amino Acid Analyzer
Kaspar, Hannelore; Dettmer, Katja; Chan, Queenie; Daniels, Scott; Nimkar, Subodh; Daviglus, Martha L.; Stamler, Jeremiah; Elliott, Paul; Oefner, Peter J.
2009-01-01
Urinary amino acid analysis is typically done by cation-exchange chromatography followed by post-column derivatization with ninhydrin and UV detection. This method lacks throughput and specificity. Two recently introduced stable isotope ratio mass spectrometric methods promise to overcome those shortcomings. Using two blinded sets of urine replicates and a certified amino acid standard, we compared the precision and accuracy of gas chromatography/mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) of propyl chloroformate and iTRAQ® derivatized amino acids, respectively, to conventional amino acid analysis. The GC-MS method builds on the direct derivatization of amino acids in diluted urine with propyl chloroformate, GC separation and mass spectrometric quantification of derivatives using stable isotope labeled standards. The LC-MS/MS method requires prior urinary protein precipitation followed by labeling of urinary and standard amino acids with iTRAQ® tags containing different cleavable reporter ions distinguishable by MS/MS fragmentation. Means and standard deviations of percent technical error (%TE) computed for 20 amino acids determined by amino acid analyzer, GC-MS, and iTRAQ®-LC-MS/MS analyses of 33 duplicate and triplicate urine specimens were 7.27±5.22, 21.18±10.94, and 18.34±14.67, respectively. Corresponding values for 13 amino acids determined in a second batch of 144 urine specimens measured in duplicate or triplicate were 8.39±5.35, 6.23±3.84, and 35.37±29.42. Both GC-MS and iTRAQ®-LC-MS/MS are suited for high-throughput amino acid analysis, with the former offering at present higher reproducibility and completely automated sample pretreatment, while the latter covers more amino acids and related amines. PMID:19481989
Urinary amino acid analysis: a comparison of iTRAQ-LC-MS/MS, GC-MS, and amino acid analyzer.
Kaspar, Hannelore; Dettmer, Katja; Chan, Queenie; Daniels, Scott; Nimkar, Subodh; Daviglus, Martha L; Stamler, Jeremiah; Elliott, Paul; Oefner, Peter J
2009-07-01
Urinary amino acid analysis is typically done by cation-exchange chromatography followed by post-column derivatization with ninhydrin and UV detection. This method lacks throughput and specificity. Two recently introduced stable isotope ratio mass spectrometric methods promise to overcome those shortcomings. Using two blinded sets of urine replicates and a certified amino acid standard, we compared the precision and accuracy of gas chromatography/mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) of propyl chloroformate and iTRAQ derivatized amino acids, respectively, to conventional amino acid analysis. The GC-MS method builds on the direct derivatization of amino acids in diluted urine with propyl chloroformate, GC separation and mass spectrometric quantification of derivatives using stable isotope labeled standards. The LC-MS/MS method requires prior urinary protein precipitation followed by labeling of urinary and standard amino acids with iTRAQ tags containing different cleavable reporter ions distinguishable by MS/MS fragmentation. Means and standard deviations of percent technical error (%TE) computed for 20 amino acids determined by amino acid analyzer, GC-MS, and iTRAQ-LC-MS/MS analyses of 33 duplicate and triplicate urine specimens were 7.27+/-5.22, 21.18+/-10.94, and 18.34+/-14.67, respectively. Corresponding values for 13 amino acids determined in a second batch of 144 urine specimens measured in duplicate or triplicate were 8.39+/-5.35, 6.23+/-3.84, and 35.37+/-29.42. Both GC-MS and iTRAQ-LC-MS/MS are suited for high-throughput amino acid analysis, with the former offering at present higher reproducibility and completely automated sample pretreatment, while the latter covers more amino acids and related amines.