Sample records for urine test results

  1. Adulterants in Urine Drug Testing.

    PubMed

    Fu, S

    Urine drug testing plays an important role in monitoring licit and illicit drug use for both medico-legal and clinical purposes. One of the major challenges of urine drug testing is adulteration, a practice involving manipulation of a urine specimen with chemical adulterants to produce a false negative test result. This problem is compounded by the number of easily obtained chemicals that can effectively adulterate a urine specimen. Common adulterants include some household chemicals such as hypochlorite bleach, laundry detergent, table salt, and toilet bowl cleaner and many commercial products such as UrinAid (glutaraldehyde), Stealth® (containing peroxidase and peroxide), Urine Luck (pyridinium chlorochromate, PCC), and Klear® (potassium nitrite) available through the Internet. These adulterants can invalidate a screening test result, a confirmatory test result, or both. To counteract urine adulteration, drug testing laboratories have developed a number of analytical methods to detect adulterants in a urine specimen. While these methods are useful in detecting urine adulteration when such activities are suspected, they do not reveal what types of drugs are being concealed. This is particularly the case when oxidizing urine adulterants are involved as these oxidants are capable of destroying drugs and their metabolites in urine, rendering the drug analytes undetectable by any testing technology. One promising approach to address this current limitation has been the use of unique oxidation products formed from reaction of drug analytes with oxidizing adulterants as markers for monitoring drug misuse and urine adulteration. This novel approach will ultimately improve the effectiveness of the current urine drug testing programs. © 2016 Elsevier Inc. All rights reserved.

  2. Sodium urine test

    MedlinePlus

    ... or monitor many types of kidney diseases. Normal Results For adults, normal urine sodium values are generally ... meaning of your specific test result. What Abnormal Results Mean A higher than normal urine sodium level ...

  3. Leukocyte esterase urine test

    MedlinePlus

    ... the urine. This may mean you have a urinary tract infection . If this test is positive, the urine should ... Results Mean An abnormal result indicates a possible urinary tract infection. The following may turn the test abnormal even ...

  4. A Prospective Blinded Evaluation of Urine-DNA Testing for Detection of Urothelial Bladder Carcinoma in Patients with Gross Hematuria.

    PubMed

    Dahmcke, Christina M; Steven, Kenneth E; Larsen, Louise K; Poulsen, Asger L; Abdul-Al, Ahmad; Dahl, Christina; Guldberg, Per

    2016-12-01

    Retrospective studies have provided proof of principle that bladder cancer can be detected by testing for the presence of tumor DNA in urine. We have conducted a prospective blinded study to determine whether a urine-based DNA test can replace flexible cystoscopy in the initial assessment of gross hematuria. A total of 475 consecutive patients underwent standard urological examination including flexible cystoscopy and computed tomography urography, and provided urine samples immediately before (n=461) and after (n=444) cystoscopy. Urine cells were collected using a filtration device and tested for eight DNA mutation and methylation biomarkers. Clinical evaluation identified 99 (20.8%) patients with urothelial bladder tumors. With this result as a reference and based on the analysis of all urine samples, the DNA test had a sensitivity of 97.0%, a specificity of 76.9%, a positive predictive value of 52.5%, and a negative predictive value of 99.0%. In three patients with a positive urine-DNA test without clinical evidence of cancer, a tumor was detected at repeat cystoscopy within 16 mo. Our results suggest that urine-DNA testing can be used to identify a large subgroup of patients with gross hematuria in whom cystoscopy is not required. We tested the possibility of using a urine-based DNA test to check for bladder cancer in patients with visible blood in the urine. Our results show that the test efficiently detects bladder cancer and therefore may be used to greatly reduce the number of patients who would need to undergo cystoscopy. Copyright © 2016 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  5. Flow meter urine testing: a practical proposition in patients attending for urodynamics?

    PubMed

    Hashim, Hashim; Abrams, Paul

    2006-05-01

    To find a practical way of detecting urinary tract infection (UTI) before invasive urodynamic testing, as UTIs after urodynamics are well documented, but there are no standard guidelines about when urine should be analysed before urodynamics. Before urodynamics all patients are asked to provide a free urine flow; the patient is then catheterized to obtain a catheter-specimen of urine that is tested for infection by a urine dipstick. If the dipstick is found positive for nitrites and/or leukocytes, the test is abandoned and the sample sent for microscopy, culture and sensitivity. In the present study, patients were asked to provide a free urine flow into the flowmeter as usual. Between patients, the flowmeter was washed with soap and water and dried, so that there would be no cross-contamination between patients' urine results. Urine was collected as usual and tested using a dipstick, the patient was then catheterized and another dipstick test done on the catheter specimen of urine (CSU), to compare results. Pairs of urine samples, when positive for nitrite were 100% consistent, and 89% of pairs positive for leukocytes were the same before and after catheterization. The remaining 11% (all women) of the positive leukocyte group had leukocytosis on testing the flowmeter urine but not on the CSU, possibly due to contamination from the vagina. Testing urine by dipstick in the sample from the flowmeter is a feasible option, thus saving the patient an inappropriate catheterization, with the risk of bacteraemia during urodynamics, and allowing the flowrate to be measured.

  6. Comparison of spot tests with AdultaCheck 6 and Intect 7 urine test strips for detecting the presence of adulterants in urine specimens.

    PubMed

    Dasgupta, Amitava; Chughtai, Omar; Hannah, Christina; Davis, Bonnette; Wells, Alice

    2004-10-01

    Several adulterants are used to mask tests for abused drugs in urine. Adulterants such as "Klear" and "Whizzies" contain potassium nitrite while "Urine Luck" contains pyridinium chlorochromate (PCC). The presence of these adulterants cannot be detected by routine specimen integrity check (pH, specific gravity, creatinine and temperature). We previously reported the development of rapid spot tests to detect the presence of these adulterants. AdultaCheck 6 and Intect 7 urine test strips are commercially available for detecting the presence of these adulterants along with specific gravity, creatinine and pH in urine. The performance of these two test strips for detecting adulterants was compared with the results obtained by spot tests. Both AdultaCheck 6 and Intect 7 effectively detected the presence of nitrite and pyridinium chlorochromate in urine. Moreover, both test strips successfully detected the presence of glutaraldehyde, for which no spot test is currently available. High amount of glucose and ascorbic acid did not cause any false positive result with AdultaCheck 6 or Intect 7. Both AdultaCheck 6 and Intect 7 can be used for checking the integrity of a urine specimen submitted for drugs of abuse testing.

  7. Rapid spot tests for detecting the presence of adulterants in urine specimens submitted for drug testing.

    PubMed

    Dasgupta, Amitava; Wahed, Amer; Wells, Alice

    2002-02-01

    Several adulterants are used to mask tests for abused drugs in urine. Adulterants such as "Klear" and "Whizzies" contain potassium nitrite, and "Urine Luck" contains pyridinium chlorochromate (PCC). The presence of these adulterants cannot be detected by routine specimen integrity checks (pH, specific gravity, and temperature). We developed rapid spot tests for detecting these adulterants in urine. Addition of 3% hydrogen peroxide in urine adulterated with PCC caused rapid formation of a dark brown color. In contrast, unadulterated urine turned colorless when hydrogen peroxide was added. When urine contaminated with nitrite and 2 to 3 drops of 2N hydrochloric acid were added to 2% aqueous potassium permanganate solution, the dark pink permanganate solution turned colorless immediately with effervescence. Urine contaminated with nitrite liberated iodine from potassium iodide solution in the presence of 2N hydrochloric acid. Urine adulterated with PCC also liberated iodine from potassium iodide in acid medium but did not turn potassium permanganate solution colorless. Urine specimens from volunteers and random urine samples that tested negative for drugs did not cause false-positive results. These rapid spot tests are useful for detecting adulterated urine to avoid false-negative drug tests.

  8. The efficacy of semi-quantitative urine protein-to-creatinine (P/C) ratio for the detection of significant proteinuria in urine specimens in health screening settings.

    PubMed

    Chang, Chih-Chun; Su, Ming-Jang; Ho, Jung-Li; Tsai, Yu-Hui; Tsai, Wei-Ting; Lee, Shu-Jene; Yen, Tzung-Hai; Chu, Fang-Yeh

    2016-01-01

    Urine protein detection could be underestimated using the conventional dipstick method because of variations in urine aliquots. This study aimed to assess the efficacy of the semi-quantitative urine protein-to-creatinine (P/C) ratio compared with other laboratory methods. Random urine samples were requested from patients undergoing chronic kidney disease screening. Significant proteinuria was determined by the quantitative P/C ratio of at least 150 mg protein/g creatinine. The semi-quantitative P/C ratio, dipstick protein and quantitative protein concentrations were compared and analyzed. In the 2932 urine aliquots, 156 (5.3 %) urine samples were considered as diluted and 60 (39.2 %) were found as significant proteinuria. The semi-quantitative P/C ratio testing had the best sensitivity (70.0 %) and specificity (95.9 %) as well as the lowest underestimation rate (0.37 %) when compared to other laboratory methods in the study. In the semi-quantitative P/C ratio test, 19 (12.2 %) had positive, 52 (33.3 %) had diluted, and 85 (54.5 %) had negative results. Of those with positive results, 7 (36.8 %) were positive detected by traditional dipstick urine protein test, and 9 (47.4 %) were positive detected by quantitative urine protein test. Additionally, of those with diluted results, 25 (48.1 %) had significant proteinuria, and all were assigned as no significant proteinuria by both tests. The semi-quantitative urine P/C ratio is clinically applicable based on its better sensitivity and screening ability for significant proteinuria than other laboratory methods, particularly in diluted urine samples. To establish an effective strategy for CKD prevention, urine protein screening with semi-quantitative P/C ratio could be considered.

  9. Timing of specimen collection is crucial in urine screening of drug dependent mothers and newborns.

    PubMed

    Halstead, A C; Godolphin, W; Lockitch, G; Segal, S

    1988-01-01

    We compared results of urine drug analysis with clinical data and history to test the usefulness of peripartum drug screening and to establish guidelines for optimal testing. Urine from 28 mothers and 52 babies was analysed. Drugs not suspected by history were found in 10 mothers and six babies. Results assisted in the management of neonatal withdrawal in three babies. Drugs suspected by history were not found in 11/22 mothers and 23/35 babies. About half of these results were associated with delayed urine collection. In 12/28 mothers, drugs administered in hospital could have confused interpretation of screen results. We conclude that urine drug screening without strict protocols for specimen collection is of limited usefulness for management of drug abuse in pregnancy and neonatal drug withdrawal. We favour testing of maternal urine obtained before drugs are administered in hospital. Neonatal urine, if used, should be collected in the first day of life.

  10. Accuracy of simple urine tests for diagnosis of urinary tract infections in low-risk pregnant women.

    PubMed

    Feitosa, Danielle Cristina Alves; da Silva, Márcia Guimarães; de Lima Parada, Cristina Maria Garcia

    2009-01-01

    Anatomic and physiological alterations during pregnancy predispose pregnant women to urinary tract infections (UTI). This study aimed to identify the accuracy of the simple urine test for UTI diagnosis in low-risk pregnant women. Diagnostic test performance was conducted in Botucatu, SP, involving 230 pregnant women, between 2006 and 2008. Results showed 10% UTI prevalence. Sensitivity, specificity and accuracy of the simple urine test were 95.6%, 63.3% and 66.5%, respectively, in relation to UTI diagnoses. The analysis of positive (PPV) and negative (NPV) predictive values showed that, when a regular simple urine test was performed, the chance of UTI occurrence was small (NPV 99.2%). In view of an altered result for such a test, the possibility of UTI existence was small (PPV 22.4%). It was concluded that the accuracy of the simple urine test as a diagnostic means for UTI was low, and that performing a urine culture is essential for appropriate diagnosis.

  11. Urine testing and urinary tract infections in febrile infants seen in office settings: the Pediatric Research in Office Settings' Febrile Infant Study.

    PubMed

    Newman, Thomas B; Bernzweig, Jane A; Takayama, John I; Finch, Stacia A; Wasserman, Richard C; Pantell, Robert H

    2002-01-01

    To determine the predictors and results of urine testing of young febrile infants seen in office settings. Prospective cohort study. Offices of 573 pediatric practitioners from 219 practices in the American Academy of Pediatrics Pediatric Research in Office Settings' research network. A total of 3066 infants 3 months or younger with temperatures of 38 degrees C or higher were evaluated and treated according to the judgment of their practitioners. Urine testing results, early and late urinary tract infections (UTIs), and UTIs with bacteremia. Fifty-four percent of the infants initially had urine tested, of whom 10% had a UTI. The height of the fever was associated with urine testing and a UTI among those tested (adjusted odds ratio per degree Celsius, 2.2 for both). Younger age, ill appearance, and lack of a fever source were associated with urine testing but not with a UTI, whereas lack of circumcision (adjusted odds ratio, 11.6), female sex (adjusted odds ratio, 5.4), and longer duration of fever (adjusted odds ratio, 1.8 for fever lasting > or = 24 hours) were not associated with urine testing but were associated with a UTI. Bacteremia accompanied the UTI in 10% of the patients, including 17% of those younger than 1 month. Among 807 infants not initially tested or treated with antibiotics, only 2 had a subsequent documented UTI; both did well. Practitioners order urine tests selectively, focusing on younger and more ill-appearing infants and on those without an apparent fever source. Such selective urine testing, with close follow-up, was associated with few late UTIs in this large study. Urine testing should focus particularly on uncircumcised boys, girls, the youngest and sickest infants, and those with persistent fever.

  12. [Examination about utility of a Streptococcus pneumoniae capsular antigen swiftness search kit urine in a pneumonia patient].

    PubMed

    Hashikita, Giichi; Yamaguti, Toshiyuki; Tachi, Yoshimi; Kishi, Etsuko; Kawamura, Toru; Takahashi, Shun; Arai, Yukie; Koyama, Sachie; Huruhata, Toshihumi; Itabashi, Akira; Oka, Yoko; Yamazaki, Tsutomu; Maesaki, Sigefumi

    2005-01-01

    We investigated the usefullness of Binax NOW urine antigen test, an immunochromatographic assay that binds any soluble Streptococcus pneumoniae antigen (C polysaccharide) for the diagnosis of penumoniae form September 2003 to March 2005. We used 372 samples form the patinets with pneumoniae diagnosed for blood or sputum cultuter or gram-stained sputum smear. Out of 24 culture positive specimens, Binax NOW urine antigen test, showed positive in 18 (75%) specimens. The sensitivity of sputum and blood culture was 71.7% and 83.3%, respectively. Binax NOW urine antigen test was seemed false positives in 55 samples, false negatives in 6 samples. The specificity of Binax NOW urine antigen test was evaluated 84.1%. Overall agreement among tests was 83.6%. When compared to culture, false negative urine antigen may be the result of colonizing S. pneumoniae in sputum or pneumonia caused by an agent other than S. pneumoniae. CRP values for cases were both urine antigen and culture were positive ranged from 40 mg/dl to 10 mg/dl while urine antigen and culture negative cases were predominantly less than 10 mg/dl. Positive blood and pleural fluid culture cases were consistently associated with strongly positive urine antigen tests. Non-agreement between urine antigen, culture, and microscopy may be the result of specimen quality, labile nature of S. pneumoniae and antimicrobial therapy.

  13. Urine drug testing results and paired oral fluid comparison from patients enrolled in long-term medication-assisted treatment in Tennessee.

    PubMed

    Miller, Katie L; Puet, Brandi L; Roberts, Ali; Hild, Cheryl; Carter, Jason; Black, David L

    2017-05-01

    Urine drug testing is recommended for individuals receiving medication-assisted treatment. It provides objective information for practitioners to consider and may serve as a protective factor against drug-related mortality. The primary objective of our study was to describe urine drug testing results for patients undergoing long-term medication-assisted treatment (≥6months). The secondary objective was to provide further evidence to establish oral fluid as a reliable alternative to urine. All subjects (n=639) included in the study were enrolled in one of five treatment centers in the state of Tennessee, and all urine specimens were positive for either methadone or buprenorphine. Nicotine (87%), caffeine (70%), marijuana (15%), alcohol (14%) and gabapentin (10%) were the most prevalent substances identified through urine drug testing. The presence of non-maintenance opioids (prescription and/or heroin) may represent relapse; these drugs were present in 10% of specimens tested. Evidence of illicit drug use (cocaine, heroin, marijuana and/or methamphetamine) was detected in 19% specimens. For 126 of the 639 subjects included in the study, paired oral fluid and urine test results were compared for agreement. Of the total paired urine and oral fluid tests, approximately 7% were positive for a drug in both specimen types and 91% were negative in both, resulting in an overall agreement of 98%. The study demonstrates continued use of illicit and commercially available medications in a medication-assisted treatment population undergoing long-term treatment. The results affirm the reliability of oral fluid as an alternative specimen type for compliance testing in this population. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. The reliability and validity of using the urine dipstick test by patient self-assessment for urinary tract infection screening in spinal cord injury patients.

    PubMed

    Duanngai, Krit; Sirasaporn, Patpiya; Ngaosinchai, Siriwan Surapaitoon

    2017-01-01

    The aim of this is to evaluate the reliability of the urine dipstick test by patients' self-assessment for urinary tract infection (UTI) screening and to determine the validity of urine dipstick test. Rehabilitation Department, Srinagarind Hospital, Thailand. A diagnostic study. This study compared the urine dipstick test (index test) with the National Institute on Disability and Rehabilitation Research (NIDRR) criteria (gold standard test) in spinal cord injury (SCI) patients. The urine dipstick test informed positive and negative results. Besides the NIDRR criteria classified as UTI and no UTI. The interrater reliability was measured in the sense of Kappa whereas the validity of urine dipstick test was reported in terms of sensitivity, specificity, positive likelihood ratio (LR) (+LR), negative LR (-LR), positive predictive value (PPV), and negative predictive value (NPV). Out of the 56 participants, the kappa of urine dipstick test for leukocyte esterase, nitrite, and combined leukocyte esterase and nitrite were 0.09, 0.21, and 0.52, respectively. The nitrite urine dipstick test showed the highest sensitivity (90%). The combined leukocyte esterase and nitrite urine dipstick test gave the highest specificity (87%), PPV (60%), NPV (93%), and +LR (5.63). The interrater reliability of combined leukocyte esterase and nitrite urine dipstick test was moderate agreement. The combined leukocyte esterase and nitrite urine dipstick test showed high level of both sensitivity and specificity. The combined leukocyte esterase and nitrite urine dipstick test should be promoted for patients' self-assessment for UTI screening in SCI patients.

  15. Workplace drug testing in Italy: findings about second-stage testing.

    PubMed

    Vignali, Claudia; Stramesi, Cristiana; Morini, Luca; San Bartolomeo, Paolo; Groppi, Angelo

    2015-03-01

    Workplace Drug Testing (WDT) in Italy includes two levels of monitoring: a first stage concerning drug testing on urine samples and a second involving both urine and hair analysis. The second stage is performed only on workers who tested positive at the first level. We analyzed urine and hair specimens from 120 workers undergoing second-level testing between 2009 and 2012. Eighty percent of them had tested positive for cannabinoids during the first level analysis, and 15.8% for cocaine. Both urine and hair samples were analyzed in order to find the following drugs of abuse: amphetamines, buprenorphine, cannabinoids, cocaine, ecstasy, methadone, and opiates. Urine analyses were performed by immunological screening (EMIT); urine confirmatory tests and hair analyses were performed by gas chromatography-mass spectrometry (GC-MS). As regards second-stage testing on urine samples, 71.2% of workers were always negative, whereas 23.9% tested positive at least once for cannabinoids and 2.5% for cocaine. Hair analyses produced surprising results: 61.9% of hair samples tested negative, only 6.2% tested positive for cannabinoids, whereas 28.8% tested positive for cocaine. These findings confirm that second-level surveillance of WDT, which includes hair analysis, is very effective because it highlights drug intake - sometimes heavy - that cannot be revealed only through urine analyses. The employees for whom drug addiction is proved can begin rehabilitation, while keeping their job. Eventually, our results confirmed the widespread and undeclared use of cocaine in Italy. Copyright © 2014 John Wiley & Sons, Ltd.

  16. Performance of the dipstick screening test as a predictor of negative urine culture

    PubMed Central

    Marques, Alexandre Gimenes; Doi, André Mario; Pasternak, Jacyr; Damascena, Márcio dos Santos; França, Carolina Nunes; Martino, Marinês Dalla Valle

    2017-01-01

    ABSTRACT Objective To investigate whether the urine dipstick screening test can be used to predict urine culture results. Methods A retrospective study conducted between January and December 2014 based on data from 8,587 patients with a medical order for urine dipstick test, urine sediment analysis and urine culture. Sensitivity, specificity, positive and negative predictive values were determined and ROC curve analysis was performed. Results The percentage of positive cultures was 17.5%. Nitrite had 28% sensitivity and 99% specificity, with positive and negative predictive values of 89% and 87%, respectively. Leukocyte esterase had 79% sensitivity and 84% specificity, with positive and negative predictive values of 51% and 95%, respectively. The combination of positive nitrite or positive leukocyte esterase tests had 85% sensitivity and 84% specificity, with positive and negative predictive values of 53% and 96%, respectively. Positive urinary sediment (more than ten leukocytes per microliter) had 92% sensitivity and 71% specificity, with positive and negative predictive values of 40% and 98%, respectively. The combination of nitrite positive test and positive urinary sediment had 82% sensitivity and 99% specificity, with positive and negative predictive values of 91% and 98%, respectively. The combination of nitrite or leukocyte esterase positive tests and positive urinary sediment had the highest sensitivity (94%) and specificity (84%), with positive and negative predictive values of 58% and 99%, respectively. Based on ROC curve analysis, the best indicator of positive urine culture was the combination of positives leukocyte esterase or nitrite tests and positive urinary sediment, followed by positives leukocyte and nitrite tests, positive urinary sediment alone, positive leukocyte esterase test alone, positive nitrite test alone and finally association of positives nitrite and urinary sediment (AUC: 0.845, 0.844, 0.817, 0.814, 0.635 and 0.626, respectively). Conclusion A negative urine culture can be predicted by negative dipstick test results. Therefore, this test may be a reliable predictor of negative urine culture. PMID:28444086

  17. Detection of Cytomegalovirus (CMV) Infection in Wheezing Infants by Urine DNA and Serum IgG Testing.

    PubMed

    Zeng, Zhao-Cheng; Chang, Qing; Sun, Zhi-Wei; Song, Ming-Mei; Jin, Xin-Ling; Jiang, Shu-Ya; Yang, Xia

    2017-03-11

    BACKGROUND The aim of this study was to investigate the involvement of CMV infection in wheezing infants and the association between CMV-DNA and immunoglobulins (Igs). MATERIAL AND METHODS A total of 243 wheezing infants and 3,000 parturients were enrolled in this study. The infants were randomly grouped to receive blood HCMV-DNA tests (n=46) or urine HCMV-DNA tests (n=197). Furthermore, all participants had serum CMV-specific IgM and IgG testing. Afterwards, 10 HCMV-IgG positive infants were randomly selected for simultaneous blood and urine HCMV-DNA tests, and 25 HCMV-IgG positive puerperants were randomly selected for urine HCMV-DNA tests. RESULTS The detection rate of urine HCMV-DNA was significantly higher than that of blood HCMV-DNA (67.5% vs. 13.0%, p<0.001). Fifteen (6.2%) and 190 (80.0%) infants showed positive CMV-specific IgM and IgG results (p<0.001), respectively. Among the 10 HCMV-IgG positive infants tested further, only two infants had positive HCMV-DNA blood tests, while all of the 10 infants had positive HCMV-DNA urine tests. However, HCMV-DNA was not detected in the urine of the 25 randomly selected parturients positive for HCMV-IgG. CONCLUSIONS CMV infection may be one of the causes of wheezing in infants; CMV infection can be detected by urine-HCMV-DNA and serum HCMV-IgG testing. Infants were more susceptible to CMV infection than parturients.

  18. Urine pretreatment for waste water processing systems. [for space station

    NASA Technical Reports Server (NTRS)

    Winkler, H. E.; Verostko, C. E.; Dehner, G. F.

    1983-01-01

    Recovery of high quality water from urine is an essential part of life support on a Space Station to avoid costly launch and resupply penalties. Water can be effectively recovered from urine by distillation following pretreatment by a chemical agent to inhibit microorganism contamination and fix volatile ammonia constituents. This paper presents the results of laboratory investigations of several pretreatment chemicals which were tested at several concentration levels in combination with sulfuric acid in urine. The optimum pretreatment formulation was then evaluated with urine in the Hamilton Standard Thermoelectric Integrated Membrane Evaporation Subsystem (TIMES). Over 2600 hours of test time was accumulated. Results of these laboratory and system tests are presented in this paper.

  19. 51Cr-EDTA absorption blood test: an easy method for assessing small intestinal permeability in dogs.

    PubMed

    Frias, Rafael; Sankari, Satu; Westermarck, Elias

    2004-01-01

    The 51Cr-EDTA test is a valuable clinical tool for screening intestinal diseases in dogs. The test is performed by calculating the percentage of recovery from urine of a PO-ingested dose of 51Cr-EDTA after 6 or 24 hours. Careful urine collection is a practical limitation of this test in dogs, and our goal was to develop a simpler test that measures 51Cr-EDTA in blood. A 51Cr-EDTA absorption test was simultaneously performed on urine and serum 43 times in healthy Beagle Dogs. Timed blood samples were withdrawn, and urine was collected during a 6-hour period. Percentages of the ingested dose were then calculated in urine and serum. The mean +/- standard deviation (range) percentage in urine after 6 hours was 14.07 +/- 8.72% (3.81-34.18%), whereas results in serum from samples taken at 2, 3, 4, 5, and 6 hours were 0.49 +/- 0.45% (0.02-2.13%), 0.75 +/- 0.52% (0.03-1.89%), 0.82 +/- 0.57% (0.13-2.21%), 0.70 +/- 0.53% (0.12-1.99%), and 0.47 +/- 0.44% (0.11-1.79%), respectively. The results for blood specimens showed good concordance with those for urine, especially for the samples taken at 4 hours (r = 0.89). Moreover, the correlation between urine and blood was better when the sum of the percentages of the recovered analyte from various blood samples was compared with urine. The correlation coefficient when summing 4 blood samples was excellent (r = 0.97) and remained excellent when summing only 2 blood samples taken at 3 and 5 hours (r = 0.95) or at 3 and 4 hours (r = 0.94). We conclude that a serum 51Cr-EDTA test determined by summing successive blood samples provides an easier means of estimating small intestinal permeability in dogs and gives results comparable to those of the 6-hour urine test.

  20. Citric acid urine test

    MedlinePlus

    Urine - citric acid test; Renal tubular acidosis - citric acid test; Kidney stones - citric acid test; Urolithiasis - citric acid test ... No special preparation is necessary for this test. But the results ... test is usually done while you are on a normal diet. Ask your ...

  1. Recommendations for provoked challenge urine testing.

    PubMed

    Ruha, Anne-Michelle

    2013-12-01

    "Urine mobilization test," "challenge test," and "provoked urine test" are all terms used to describe the administration of a chelating agent to a person prior to collection of their urine to test for metals. There is no standard, validated challenge test. Despite recommendations by professional and government organizations against the use of provoked urine testing, the tests are still commonly used and recommended by some practitioners. Challenge testing utilizes a variety of chelating agents, including dimercaptosuccinic acid (DMSA), dimercaptopropanesulfonate (DMPS), and ethylenediaminetetraacetic acid (EDTA). The agents are given by a variety of routes of administration, doses used are inconsistent, and urine collection procedures vary. Additional problems with challenge tests include comparison of results to inappropriate reference ranges and creatinine correction of urine obtained within hours of chelator administration. Human volunteer studies demonstrate that mercury is detected in the urine of most people even in the absence of known exposure or chelator administration, and that urinary mercury excretion rises after administration of a chelator, regardless of exposure history and in an unpredictable fashion. Studies also demonstrate that challenge testing fails to reveal a "body burden" of mercury due to remote exposure. Chelating agents have been associated with adverse reactions. Current evidence does not support the use of DMPS, DMSA, or other chelation challenge tests for the diagnosis of metal toxicity. Since there are no established reference ranges for provoked urine samples in healthy subjects, no reliable evidence to support a diagnostic value for the tests, and potential harm, these tests should not be utilized.

  2. Role of Urine Drug Testing in the Current Opioid Epidemic.

    PubMed

    Mahajan, Gagan

    2017-12-01

    While the evidence for urine drug testing for patients on chronic opioid therapy is weak, the guidelines created by numerous medical societies and state and federal regulatory agencies recommend that it be included as one of the tools used to monitor patients for compliance with chronic opioid therapy. To get the most comprehensive results, clinicians should order both an immunoassay screen and confirmatory urine drug test. The immunoassay screen, which can be performed as an in-office point-of-care test or as a laboratory-based test, is a cheap and convenient study to order. Limitations of an immunoassay screen, however, include having a high threshold of detectability and only providing qualitative information about a select number of drug classes. Because of these restrictions, clinicians should understand that immunoassay screens have high false-positive and false-negative rates. Despite these limitations, though, the results can assist the clinician with making preliminary treatment decisions. In comparison, a confirmatory urine drug test, which can only be performed as a laboratory-based test, has a lower threshold of detectability and provides both qualitative and quantitative information. A urine drug test's greater degree of specificity allows for a relatively low false-negative and false-positive rate in contrast to an immunoassay screen. Like any other diagnostic test, an immunoassay screen and a confirmatory urine drug test both possess limitations. Clinicians must keep this in mind when interpreting an unexpected test result and consult with their laboratory when in doubt about the meaning of the test result to avoid making erroneous decisions that negatively impact both the patient and clinician.

  3. Catecholamines - urine

    MedlinePlus

    Dopamine - urine test; Epinephrine - urine test; Adrenalin - urine test; Urine metanephrine; Normetanephrine; Norepinephrine - urine test; Urine catecholamines; VMA; HVA; Metanephrine; Homovanillic ...

  4. Non-invasive Pregnancy Diagnosis from Urine by the Cuboni Reaction and the Barium Chloride Test in Donkeys (Equus asinus) and Alpacas (Vicugna pacos).

    PubMed

    Kubátová, A; Fedorova, T; Skálová, I; Hyniová, L

    2016-09-01

    The aim of the research was to evaluate two chemical tests for non-invasive pregnancy diagnosis from urine, the Cuboni reaction and the barium chloride test, in donkeys (Equus asinus) and alpacas (Vicugna pacos). The research was carried out from April 2013 to September 2014. Urine samples were collected on five private Czech farms from 18 jennies and 12 alpaca females. Urine was collected non-invasively into plastic cups fastened on a telescopic rod, at 6-9 week intervals. In total, 60 and 54 urine samples from alpacas and jennies, respectively, were collected. The Cuboni reaction was performed by the State Veterinary Institute Prague. The barium chloride test was done with 5 ml of urine mixed together with 5 ml of 1% barium chloride solution. Results of the Cuboni reaction were strongly influenced by the reproductive status of jennies; the test was 100% successful throughout the second half of pregnancy. However, no relationship was found between the real reproductive status of alpaca females and results of the Cuboni reaction. It was concluded that the barium chloride test is not suitable for pregnancy diagnosis either in donkeys, due to significant influence of season on the results, or in alpacas, because no relationship between results of the test and the reproductive status of alpaca females was found. In conclusion, the Cuboni reaction has potential to become a standard pregnancy diagnostic method in donkeys.

  5. Myoglobin urine test

    MedlinePlus

    Urine myoglobin; Heart attack - myoglobin urine test; Myositis - myoglobin urine test; Rhabdomyolysis - myoglobin urine test ... The test involves only normal urination, which should cause no discomfort.

  6. Prevalence of isolated non-albumin proteinuria in the US population tested for both, urine total protein and urine albumin: An unexpected discovery.

    PubMed

    Katayev, Alexander; Zebelman, Arthur M; Sharp, Thomas M; Samantha Flynn; Bernstein, Richard K

    2017-04-01

    Isolated non-albumin proteinuria (NAP) is a condition when urine total protein concentrations are elevated without elevation of urine albumin. The prevalence of NAP in the US population tested for both, urine total protein and albumin was assessed in this study. The database of a US nationwide laboratory network was queried for test results when random urine albumin was ordered together with urine total protein and also when timed 24-hour urine albumin was ordered together with urine total protein. The total prevalence of NAP in the US population tested for both, urine total protein and albumin was calculated for patient groups having normal and low-normal urine albumin (random and timed) with elevated and severely increased urine total protein (random and timed). Also, the prevalence of NAP was calculated for patients with normal urine albumin to assess the probability of missing proteinuria if only urine albumin is measured. The prevalence of NAP in the random samples group was 10.1% (15.2% for females and 4.7% for males). Among patients with normal random albumin, there were 20.0% (27.3% of females and 10.7% of males) patients with NAP. The prevalence of NAP in the timed samples group was 24.6% (29.8% for females and 18.5% for males). Among patients with normal timed urine albumin, there were 36.2% (40.0% of females and 30.8% of males) patients with NAP. There was a strong positive association with female gender and NAP in most patients groups. Testing for only urine (micro)albumin can miss up to 40% of females and 30.8% of males with gross proteinuria. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  7. A pilot study to assess if urine specific gravity and urine colour charts are useful indicators of dehydration in acute stroke patients.

    PubMed

    Rowat, Anne; Smith, Laura; Graham, Cat; Lyle, Dawn; Horsburgh, Dorothy; Dennis, Martin

    2011-09-01

    The purpose of this pilot study was to examine whether urine specific gravity and urine colour could provide an early warning of dehydration in stroke patients compared with standard blood indicators of hydration status. Dehydration after stroke has been associated with increased blood viscosity, venous thrombo-embolism and stroke mortality at 3-months. Earlier identification of dehydration might allow us to intervene to prevent significant dehydration developing or reduce its duration to improve patient outcomes. We recruited 20 stroke patients in 2007 and measured their urine specific gravity with urine test strips, a refractometer, and urine colour of specimens taken daily on 10 consecutive days and compared with the routine blood urea:creatinine ratios over the same period to look for trends and relationships over time. The agreement between the refractometer, test strips and urine colour were expressed as a percentage with 95% confidence intervals. Nine (45%) of the 20 stroke patients had clinical signs of dehydration and had a significantly higher admission median urea:creatinine ratio (P = 0·02, Mann-Whitney U-test). There were no obvious relationships between urine specific gravity and urine colour with the urea:creatinine ratio. Of the 174 urine samples collected, the refractometer agreed with 70/174 (40%) urine test strip urine specific gravity and 117/174 (67%) urine colour measurements. Our results do not support the use of the urine test strip urine specific gravity as an early indicator of dehydration. Further research is required to develop a practical tool for the early detection of dehydration in stroke patients. © 2011 Blackwell Publishing Ltd.

  8. Ketones urine test

    MedlinePlus

    Ketone bodies - urine; Urine ketones; Ketoacidosis - urine ketones test; Diabetic ketoacidosis - urine ketones test ... Urine ketones are usually measured as a "spot test." This is available in a test kit that ...

  9. Comparison of Test Results for Zika Virus RNA in Urine, Serum, and Saliva Specimens from Persons with Travel-Associated Zika Virus Disease - Florida, 2016.

    PubMed

    Bingham, Andrea M; Cone, Marshall; Mock, Valerie; Heberlein-Larson, Lea; Stanek, Danielle; Blackmore, Carina; Likos, Anna

    2016-05-13

    In May 2015, Zika virus was reported to be circulating in Brazil. This was the first identified introduction of the virus in the Region of the Americas. Since that time, Zika virus has rapidly spread throughout the region. As of April 20, 2016, the Florida Department of Health Bureau of Public Health Laboratories (BPHL) has tested specimens from 913 persons who met state criteria for Zika virus testing. Among these 913 persons, 91 met confirmed or probable Zika virus disease case criteria and all cases were travel-associated (1). On the basis of previous small case studies reporting real time reverse-transcription polymerase chain reaction (RT-PCR) detection of Zika virus RNA in urine, saliva, and semen (2-6), the Florida Department of Health collected multiple specimen types from persons with suspected Zika virus disease. Test results were evaluated by specimen type and number of days after symptom onset to determine the most sensitive and efficient testing algorithm for acute Zika virus disease. Urine specimens were collected from 70 patients with suspected Zika virus disease from zero to 20 days after symptom onset. Of these, 65 (93%) tested positive for Zika virus RNA by RT-PCR. Results for 95% (52/55) of urine specimens collected from persons within 5 days of symptom onset tested positive by RT-PCR; only 56% (31/55) of serum specimens collected on the same date tested positive by RT-PCR. Results for 82% (9/11) of urine specimens collected >5 days after symptom onset tested positive by RT-PCR; none of the RT-PCR tests for serum specimens were positive. No cases had results that were exclusively positive by RT-PCR testing of saliva. BPHL testing results suggest urine might be the preferred specimen type to identify acute Zika virus disease.

  10. Validation of a urine circulating cathodic antigen cassette test for detection of Schistosoma haematobiumin uMkhanyakude district of South Africa.

    PubMed

    Rubaba, O; Chimbari, M J; Soko, W; Manyangadze, T; Mukaratirwa, S

    2018-06-01

    Circulating cathodic antigen (CCA) tests for schistosomiasis are fast and less complicated allowing making them good candidates for routine qualitative screening for schistosomiasis at point of care. The urine-CCA has been evaluated for detection of S. mansoni with promising results. Its specificity and consistency in detecting S. haematobium infection in different endemic regions has been variable. This study validated a rapid urine-CCA cassette test for qualitative detection of S. haematobium infection in an S. haematobium endemic area with low S. mansoni prevalence. Microscopic examination for the standard urine filtration technique was used to validate the commercially available urine-CCA cassette test (rapid medical diagnostics ® ). The validation was done in a sample of primary school pupils (n = 420) aged 10-15 years in schools in the Jozini Municipality, KZN. There was a relationship between infection intensity and a positive urine-CCA test. Using the urine filtration method as the gold standard, the prevalence for S. haematobium was 40%, the accuracy of the CCA kit was 54.8%, sensitivity was 68.1% while the specificity was 45.8%. The positive predictive value was 45.82% while the negative predictive value was 68.05%. Both the urine filtration and the urine-CCA methods detected heavy (≥50 eggs/10 mL urine) and light infections at statistically significant levels. The overall accuracy, sensitivity and specificity of the urine-CCA cassette test were low. The urine-CCA cassette test performed much better for heavy infections than low infections (p < 0.05) implying that the kit may not be suitable for low endemic areas. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. The diagnostic accuracy of the rapid dipstick test to predict asymptomatic urinary tract infection of pregnancy.

    PubMed

    Eigbefoh, J O; Isabu, P; Okpere, E; Abebe, J

    2008-07-01

    Untreated urinary tract infection can have devastating maternal and neonatal effects. Thus, routine screening for bacteriuria is advocated. This study was designed to evaluate the diagnostic accuracy of the rapid dipstick test to predict urinary tract infection in pregnancy with the gold standard of urine microscopy, culture and sensitivity acting as the control. The urine dipstick test uses the leucocyte esterase, nitrite and test for protein singly and in combination. The result of the dipstick was compared with the gold standard, urine microscopy, culture and sensitivity using confidence interval for proportions. The reliability and validity of the urine dipstick was also evaluated. Overall, the urine dipstick test has a poor correlation with urine culture (p = 0.125, CI 95%). The same holds true for individual components of the dipstick test. The overall sensitivity of the urine dipstick test was poor at 2.3%. Individual sensitivity of the various components varied between 9.1% for leucocyte esterase and the nitrite test to 56.8% for leucocyte esterase alone. The other components of the dipstick test, the test of nitrite, test for protein and combination of the test (leucocyte esterase, nitrite and proteinuria) appear to decrease the sensitivity of the leucocyte esterase test alone. The ability of the urine dipstick test to correctly rule out urinary tract infection (specificity) was high. The positive predictive value for the dipstick test was high, with the leucocyte esterase test having the highest positive predictive value compared with the other components of the dipstick test. The negative predictive value (NPV) was expectedly highest for the leucocyte esterase test alone with values higher than the other components of the urine dipstick test singly and in various combinations. Compared with the other parameters of the urine dipstick test, singly and in combination, leucocyte esterase appears to be the most accurate (90.25%). The dipstick test has a limited use in screening for asymptomatic bacteriuria. The leucocyte esterase test component of the dipstick test appears to have the highest reliability and validity. The other parameters of the dipstick test decreases the reliability and validity of the leucocyte esterase test. A positive test merits empirical antibiotics, while a negative test is an indication for urine culture. The urine dipstick test if positive will also be useful in follow-up of patient after treatment of urinary tract infection. This is useful in poor resource setting especially in the third world where there is a dearth of trained personnel and equipment for urine culture.

  12. Hair and urine testing to assess drugs of abuse consumption in couples undergoing assisted reproductive technology (ART).

    PubMed

    Pichini, Simona; De Luca, Roberto; Pellegrini, Manuela; Marchei, Emilia; Rotolo, Maria Concetta; Spoletini, Roberta; D'Aloja, Paola; Pacifici, Roberta; Mortali, Claudia; Scaravelli, Giulia

    2012-05-10

    For the first time in Europe hair and urine testing have been applied to assess drugs of abuse consumption in couples undergoing assisted reproductive technology and the eventual association of toxic habits with other lifestyle, health status and sociodemographic factors was also investigated. Couples attending five assisted reproduction centers in Rome were invited to join the study. When they presented at the Centre for the visit, they were asked to answer a structured questionnaire concerning sociodemographic characteristics and lifestyle habits, and at the same time to provide hair and urine samples. Hair and urine testing for drugs of abuse, urinary profile of principal endogenous steroids involved in fertility process (testosterone, epitestosterone, androsterone, etiocholanolone and dehydroepiandrosterone) and of alcohol and tobacco smoke biomarkers were performed with validated methodologies. Of the 594 enrolled individuals (297 couples), 352 (164 couples and 24 single individuals from the couple) completed the questionnaire and gave both hair and urine samples, apart from 3 bald men, who only gave urine samples. Urine testing showed an overall 4.8% (17 individuals) positivity to drugs of abuse: 4.2% to cannabinoids, 1.4% to cocaine and 0.85% to both drugs. Results of 4cm segment hair samples testing matched those from urine samples. Thus, taking together, results of urine and hair testing confirmed repeated use of cannabis, cocaine and both drugs in 3.7, 0.85 and 0.57% examined individuals, respectively. Drug consumers were in a statistically higher percentage active smokers and alcohol drinkers, less prone to physical activity and with a trend towards higher weight than non consumers. Finally, repeated drug consumption was associated with significant lower concentration of urinary testosterone in males and of urinary dehydroepiandrosterone in females. The findings of the present study confirm the suitability of urine testing to disclose recent drugs of abuse consumption and of hair analysis to verify repeated consumption. Association between different toxic habits and sedentary lifestyle is also substantiated by the obtained results in our cohort of couples attending assisted reproduction centers. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  13. Survey of antibiotic residues in Canadian slaughter animals.

    PubMed Central

    Tittiger, F; Kingscote, B; Meldrum, B; Prior, M

    1975-01-01

    Kidneys and urine of cattle, swine, sheep and chickens were tested for bacterial growth inhibitors using Bacillus subtilis and Sarcina lutea as test organisms. Results were as follows: 211 beef kidneys four positive, 611 swine kidneys five positive, 27 sheep and 120 chicken kidneys all negative, 2108 beef urine 76 positive, 2409 swine urine 186 positive, 176 sheep urine 17 positive. Strongest reactions were obtained with B. subtilis on phosphate buffered pH 6.0 plates. Larger zones were produced by urine from injected animals than by tissue samples. PMID:236082

  14. Oral fluid vs. Urine Analysis to Monitor Synthetic Cannabinoids and Classic Drugs Recent Exposure

    PubMed Central

    Blandino, Vincent; Wetzel, Jillian; Kim, Jiyoung; Haxhi, Petrit; Curtis, Richard; Concheiro, Marta

    2018-01-01

    Background Urine is a common biological sample to monitor recent drug exposure, and oral fluid is an alternative matrix of increasing interest in clinical and forensic toxicology. Limited data are available about oral fluid vs. urine drug disposition, especially for synthetic cannabinoids. Objective To compare urine and oral fluid as biological matrices to monitor recent drug exposure among HIV-infected homeless individuals. Methods Seventy matched urine and oral fluid samples were collected from 13 participants. Cannabis, amphetamines, benzodiazepines, cocaine and opiates were analyzed in urine by the enzyme-multiplied-immunoassay-technique and in oral fluid by liquid chromatography tandem mass spectrometry (LC-MSMS). Eleven synthetic cannabinoids were analyzed in urine and in oral fluid by LC-MSMS. Results Five oral fluid samples were positive for AB-FUBINACA. In urine, 4 samples tested positive for synthetic cannabinoids PB-22, 5-Fluoro-PB-22, AB-FUBINACA, and metabolites UR-144 5-pentanoic acid and UR-144 4-hydroxypentyl. In only one case, oral fluid and urine results matched, both specimens being AB-FUBINACA positive. For cannabis, 40 samples tested positive in urine and 30 in oral fluid (85.7% match). For cocaine, 37 urine and 52 oral fluid samples were positive (75.7% match). Twenty-four urine samples were positive for opiates, and 25 in oral fluid (81.4% match). For benzodiazepines, 23 samples were positive in urine and 25 in oral fluid (85.7% match). Conclusion/Discussion These results offer new information about drugs disposition between urine and oral fluid. Oral fluid is a good alternative matrix to urine for monitoring cannabis, cocaine, opiates and benzodiazepines recent use; however, synthetic cannabinoids showed mixed results. PMID:29173162

  15. Urinalysis

    MedlinePlus

    ... urine To diagnose a urinary tract infection Normal Results Normal urine varies in color from almost colorless ... meaning of your specific test results. What Abnormal Results Mean Abnormal results may mean you have an ...

  16. Laboratory and clinical evaluation of on-site urine drug testing.

    PubMed

    Beck, Olof; Carlsson, Sten; Tusic, Marinela; Olsson, Robert; Franzen, Lisa; Hulten, Peter

    2014-11-01

    Products for on-site urine drug testing offer the possibility to perform screening for drugs of abuse directly at the point-of-care. This is a well-established routine in emergency and dependency clinics but further evaluation of performance is needed due to inherent limitations with the available products. Urine drug testing by an on-site product was compared with routine laboratory methods. First, on-site testing was performed at the laboratory in addition to the routine method. Second, the on-site testing was performed at a dependency clinic and urine samples were subsequently sent to the laboratory for additional analytical investigation. The on-site testing products did not perform with assigned cut-off levels. The subjective reading between the presence of a spot (i.e. negative test result) being present or no spot (positive result) was difficult in 3.2% of the cases, and occurred for all parameters. The tests performed more accurately in drug negative samples (specificity 96%) but less accurately for detecting positives (sensitivity 79%). Of all incorrect results by the on-site test the proportion of false negatives was 42%. The overall agreement between on-site and laboratory testing was 95% in the laboratory study and 98% in the clinical study. Although a high degree of agreement was observed between on-site and routine laboratory urine drug testing, the performance of on-site testing was not acceptable due to significant number of false negative results. The limited sensitivity of on-site testing compared to laboratory testing reduces the applicability of these tests.

  17. False-positive buprenorphine EIA urine toxicology results due to high dose morphine: a case report.

    PubMed

    Tenore, Peter L

    2012-01-01

    In monitoring a patient with chronic pain who was taking high-dose morphine and oxycodone with weekly urine enzymatic immunoassay (EIA) toxicology testing, the authors noted consistent positives for buprenorphine. The patient was not taking buprenorphine, and gas chromatography/mass spectroscopy (GCMS) testing on multiple samples revealed no buprenorphine, indicating a case of false-positive buprenorphine EIAs in a high-dose opiate case. The authors discontinued oxycodone for a period of time and then discontinued morphine. Urine monitoring with EIAs and GCMS revealed false-positive buprenorphine EIAs, which remained only when the patient was taking morphine. When taking only oxycodone and no morphine, urine samples became buprenorphine negative. When morphine was reintroduced, false-positive buprenorphine results resumed. Medical practitioners should be aware that high-dose morphine (with morphine urine levels turning positive within the 15,000 to 28,000 mg/mL range) may produce false-positive buprenorphine EIAs with standard urine EIA toxicology testing.

  18. Evaluation of Aution Max AX-4030 and 9UB Uriflet, 10PA Aution Sticks urine dipsticks in the automated urine test strip analysis.

    PubMed

    Rota, Cristina; Biondi, Marco; Trenti, Tommaso

    2011-09-26

    Aution Max AX-4030, a test strip analyzer recently introduced to the market, represents an upgrade of the Aution Max AX-4280 widely employed for urinalysis. This new instrument model can allocate two different test strips at the same time. In the present study the two instruments have been compared together with the usage of Uriflet 9UB and the recently produced Aution Sticks 10PA urine strips, the latter presenting an additional test area for the measurement of urinary creatinine. Imprecision and correlation between instruments and strips have been evaluated for chemical-physical parameters. Accuracy was evaluated for protein, glucose and creatinine by comparing the semi-quantitative results to those obtained by quantitative methods. The well-known interference effect of high ascorbic acid levels on urine glucose test strip determination was evaluated, ascorbic acid influence was also evaluated on protein and creatinine determination. The two instruments have demonstrated comparable performances: precision and correlation between instruments and strips, evaluated for chemical-physical parameters, were always good. Furthermore, accuracy was always very good: results of protein and glucose semi-quantitative measurements resulted to be highly correlated with those obtained by quantitative methods. Moreover, the semi-quantitative measurements of creatinine, employing Aution Sticks 10PA urine strips, were highly comparable with quantitative results. 10PA urine strips are eligible for urine creatinine determination with the possibility of correcting urinalysis results for urinary creatinine concentration, whenever necessary and calculating the protein creatinine ratio. Further studies should be carried out to evaluate effectiveness and appropriateness of the usage of creatinine semi-quantitative analysis.

  19. Diagnostic performance of urine dipstick testing in children with suspected UTI: a systematic review of relationship with age and comparison with microscopy.

    PubMed

    Mori, R; Yonemoto, N; Fitzgerald, A; Tullus, K; Verrier-Jones, K; Lakhanpaul, M

    2010-04-01

    Prompt diagnosis of urinary tract infection (UTI) in children is needed to initiate treatment but is difficult to establish without urine testing, and reliance on culture leads to delay. Urine dipsticks are often used as an alternative to microscopy, although the diagnostic performance of dipsticks at different ages has not been established systematically. Studies comparing urine dipstick testing in infants versus older children and urine dipstick versus microscopy were systematically searched and reviewed. Meta-analysis of available studies was conducted. Six studies addressed these questions. The results of meta-analysis showed that the performance of urine dipstick testing was significantly less in the younger children when compared with older children (p < 0.01). Positive likelihood ratio (LR) of both nitrite and leucocyte positive 38.54 [95% confidence interval (CI) 22.49-65.31], negative LR for both negative 0.13 (95% CI 0.07-0.25) are reasonably good, and those for young infants are less reliable [positive LR 7.62 (95% CI 0.95-51.85) and negative LR 0.34 (95% CI 0.66-0.15)]. Comparing microscopy and urine dipstick testing, using bacterial colony count on urine culture showed no significant difference between the two methods. Urine dipstick testing is more effective for diagnosis of UTI in children over 2 years than for younger children.

  20. Does the Exposure of Urine Samples to Air Affect Diagnostic Tests for Urine Acidification?

    PubMed Central

    Yi, Joo-Hark; Shin, Hyun-Jong; Kim, Sun-Moon; Han, Sang-Woong; Oh, Man-Seok

    2012-01-01

    Summary Background and objectives For accurate measurement of pH, urine collection under oil to limit the escape of CO2 on air exposure is recommended. This study aims to test the hypothesis that urine collection under oil is not necessary in acidic urine in which bicarbonate and CO2 are minor buffers, because loss of CO2 would have little effect on its pH. Design, setting, participants, & measurements One hundred consecutive random urine samples were collected under oil and analyzed for pH, pCO2, and HCO3− immediately and after 5 minutes of vigorous shaking in uncovered flasks to allow CO2 escape. Results The pH values in 97 unshaken samples ranged from 5.03 to 6.83. With shaking, urine pCO2 decreased by 76%, whereas urine HCO3− decreased by 60%. Meanwhile, urine baseline median pH (interquartile range) of 5.84 (5.44–6.25) increased to 5.93 (5.50–6.54) after shaking (ΔpH=0.12 [0.07–0.29], P<0.001). ΔpH with pH≤6.0 was significantly lower than the ΔpH with pH>6.0 (0.08 [0.05–0.12] versus 0.36 [0.23–0.51], P<0.001). Overall, the lower the baseline pH, the smaller the ΔpH. Conclusions The calculation of buffer reactions in a hypothetical acidic urine predicted a negligible effect on urine pH on loss of CO2 by air exposure, which was empirically proven by the experimental study. Therefore, exposure of urine to air does not substantially alter the results of diagnostic tests for urine acidification, and urine collection under oil is not necessary. PMID:22700881

  1. Comparison between Urine and Cervical Samples for HPV DNA Detection and Typing in Young Women in Colombia.

    PubMed

    Cómbita, Alba Lucía; Gheit, Tarik; González, Paula; Puerto, Devi; Murillo, Raúl Hernando; Montoya, Luisa; Vorsters, Alex; Van Keer, Severien; Van Damme, Pierre; Tommasino, Massimo; Hernández-Suárez, Gustavo; Sánchez, Laura; Herrero, Rolando; Wiesner, Carolina

    2016-09-01

    Urine sampling for HPV DNA detection has been proposed as an effective method for monitoring the impact of HPV vaccination programs; however, conflicting results have been reported. The goal of this study was to evaluate the performance of optimized urine HPV DNA testing in women aged 19 to 25 years. Optimization process included the use of first void urine, immediate mixing of urine with DNA preservative, and the concentration of all HPV DNA, including cell-free DNA fragments. Urine and cervical samples were collected from 535 young women attending cervical screening at health centers from two Colombian cities. HPV DNA detection and genotyping was performed using an HPV type-specific multiplex genotyping assay, which combines multiplex polymerase chain reaction with bead-based Luminex technology. Concordance between HPV DNA detection in urine and cervical samples was determined using kappa statistics and McNemar tests. The accuracy of HPV DNA testing in urine samples was evaluated measuring sensitivity and specificity using as reference the results obtained from cervical samples. Statistical analysis was performed using STATA11.2 software. The findings revealed an overall HPV prevalence of 60.00% in cervical samples and 64.72% in urine samples, HPV-16 being the most frequent HPV type detected in both specimens. Moreover, our results indicate that detection of HPV DNA in first void urine provides similar results to those obtained with cervical samples and can be used to monitor HPV vaccination trials and programs as evidenced by the substantial concordance found for the detection of the four vaccine types. Cancer Prev Res; 9(9); 766-71. ©2016 AACR. ©2016 American Association for Cancer Research.

  2. Urinalysis: MedlinePlus Health Topic

    MedlinePlus

    ... Urine odor (Medical Encyclopedia) Also in Spanish Urine pH test (Medical Encyclopedia) Also in Spanish Urine specific gravity ... Urine - abnormal color Urine - bloody Urine odor Urine pH test Urine specific gravity test Show More Show Less ...

  3. Results of hair analyses for drugs of abuse and comparison with self-reports and urine tests.

    PubMed

    Musshoff, F; Driever, F; Lachenmeier, K; Lachenmeier, D W; Banger, M; Madea, B

    2006-01-27

    Urine as well as head and pubic hair samples from drug abusers were analysed for opiates, cocaine and its metabolites, amphetamines, methadone and cannabinoids. Urine immunoassay results and the results of hair tests by means of gas chromatography-mass spectrometry were compared to the self-reported data of the patients in an interview protocol. With regard to the study group, opiate abuse was claimed from the majority in self-reports (89%), followed by cannabinoids (55%), cocaine (38%), and methadone (32%). Except for opiates the comparison between self-reported drug use and urinalysis at admission showed a low correlation. In contrast to urinalysis, hair tests revealed consumption in more cases. There was also a good agreement between self-reports of patients taking part in an official methadone maintenance program and urine test results concerning methadone. However, hair test results demonstrated that methadone abuse in general was under-reported by people who did not participate in a substitution program. Comparing self-reports and the results of hair analyses drug use was dramatically under-reported, especially cocaine. Cocaine hair tests appeared to be highly sensitive and specific in identifying past cocaine use even in settings of negative urine tests. In contrast to cocaine, hair lacks sensitivity as a detection agent for cannabinoids and a proof of cannabis use by means of hair analysis should include the sensitive detection of the metabolite THC carboxylic acid in the lower picogram range.

  4. 49 CFR 40.13 - How do DOT drug and alcohol tests relate to non-DOT tests?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... drugs, and a laboratory is prohibited from making a DOT urine specimen available for a DNA test or other... a blood or urine specimen collected by the employee's physician or a DNA test result purporting to...

  5. 49 CFR 40.13 - How do DOT drug and alcohol tests relate to non-DOT tests?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... drugs, and a laboratory is prohibited from making a DOT urine specimen available for a DNA test or other... a blood or urine specimen collected by the employee's physician or a DNA test result purporting to...

  6. 49 CFR 40.13 - How do DOT drug and alcohol tests relate to non-DOT tests?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... drugs, and a laboratory is prohibited from making a DOT urine specimen available for a DNA test or other... a blood or urine specimen collected by the employee's physician or a DNA test result purporting to...

  7. 49 CFR 40.13 - How do DOT drug and alcohol tests relate to non-DOT tests?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... drugs, and a laboratory is prohibited from making a DOT urine specimen available for a DNA test or other... a blood or urine specimen collected by the employee's physician or a DNA test result purporting to...

  8. 49 CFR 40.13 - How do DOT drug and alcohol tests relate to non-DOT tests?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... drugs, and a laboratory is prohibited from making a DOT urine specimen available for a DNA test or other... a blood or urine specimen collected by the employee's physician or a DNA test result purporting to...

  9. Urine Toxicology in Adults Evaluated for a Central Hypersomnia and How the Results Modify the Physician's Diagnosis

    PubMed Central

    Kosky, Christopher A.; Bonakis, Anastasios; Yogendran, Arthee; Hettiarachchi, Gihan; Dargan, Paul I.; Williams, Adrian J.

    2016-01-01

    Study Objectives: Drugs and psychoactive substances can cause sleepiness and when undetected, may lead to over diagnosis of central hypersomnias. We performed urine drug testing using gas chromatography-mass spectrometry in adults undergoing multiple sleep latency testing (MSLT) for a suspected central hypersomnia. We examined how the drug test results modified the treating physician's diagnosis. Methods: One hundred eighty-six consecutive patients with a suspected central hypersomnia who underwent clinical assessment, MSLT and urine drug testing by gas chromatography-mass spectrometry were retrospectively studied. Physicians made a diagnosis after clinical assessment and MSLT and were initially blinded to the urine drug test results. Results: A third of patients assessed for subjective hypersomnia had a positive urine drug test for a substance affecting sleep. Opioids, cannabis, and amphetamines were the commonest drugs detected. Using MSLT, 35 (18.8%) of 186 patients had objective hypersomnia that may have been due to a drug or substance. Drugs or substances may have confounded the MSLT in 11 (20.1%) of 53 patients who fulfilled diagnostic criteria for idiopathic hypersomnia, and 12 (52%) of 23 of those who fulfilled diagnostic criteria for narcolepsy without cataplexy. Of the 75 positive urine drug samples, 61 (81%) were substances or medications not revealed in the physician interview. The treating physician had not suspected drugs or substances as a possible cause of objective hypersomnia in 34 (97%) of the 35 patients. Conclusions: Drugs and psychoactive substances can confound the results of the MSLT and when undetected could lead to over diagnosis of central hypersomnias. Citation: Kosky CA, Bonakis A, Yogendran A, Hettiarachchi G, Dargan PI, Williams AJ. Urine toxicology in adults evaluated for a central hypersomnia and how the results modify the physician's diagnosis. J Clin Sleep Med 2016;12(11):1499–1505. PMID:27568897

  10. 24-hour urine protein

    MedlinePlus

    ... one urine sample (protein-to-creatinine ratio). Normal Results The normal value is less than 100 milligrams ... meaning of your specific test results. What Abnormal Results Mean Abnormal results may be due to: A ...

  11. Urine chemistry

    MedlinePlus

    ... rate 24-hour urine protein Acid loading test (pH) Adrenalin - urine test Amylase - urine Bilirubin - urine Calcium - urine Citric acid ... Urine dermatan sulfate Urine - hemoglobin Urine metanephrine Urine pH Urine specific gravity Vanillylmandelic acid (VMA)

  12. Lower Cutoffs for LC-MS/MS Urine Drug Testing Indicates Better Patient Compliance.

    PubMed

    Krock, Kevin; Pesce, Amadeo; Ritz, Dennis; Thomas, Richard; Cua, Agnes; Rogers, Ryan; Lipnick, Phil; Kilbourn, Kristen

    2017-11-01

    Urine drug testing is used by health care providers to determine a patient's compliance to their prescribed regimen and to detect non-prescribed medications and illicit drugs. However, the cutoff levels used by clinical labs are often arbitrarily set and may not reflect the urine drug concentrations of compliant patients. Our aim was to test the hypothesis that commonly used cutoffs for many prescribed and illicit drugs were set too high, and methods using these cutoffs may yield a considerable number of false-negative results. The goals of this study were to outline the way to analyze patient results and estimate a more appropriate cutoff, develop and validate a high sensitivity analytical method capable of quantitating drugs and metabolites at lower than the commonly used cutoffs, and determine the number of true positive results that would have been missed when using the common cutoffs. This was a retrospective study of urine specimens submitted for urine drug testing as part of the monitoring of prescription drug compliance described in chronic opioid therapy treatment guidelines. The study was set in a clinical toxicology laboratory, using specimens submitted for routine analysis by health care providers in the normal course of business. Lognormal distributions of test results were generated and fitted with a trendline to estimate the required cutoff level necessary to capture the normal distributions of each drug for the patient population study. A validated laboratory derived liquid chromatography tandem mass spectrometry (LC-MS/MS) analysis capable of achieving the required cutoff levels was developed for each drug and/or metabolite. The study shows that a lognormal distribution of patient urine test results fitted with a trendline is appropriate for estimating the required cutoff levels needed to assess medication adherence. The study showed a wide variation in the false-negative rate, ranging from 1.5% to 94.3% across a range of prescribed and illicit drugs. The patient specimens were largely sourced from patients in either a long-term pain management program or in treatment for substance use disorder in the US. These specimens may not be representative of patients in other types of treatment or in countries with different approaches to these issues. The high-sensitivity method reduces false-negative results which could negatively impact patient care. Clinicians using less sensitive methods for detecting and quantifying drugs and metabolites in urine should exercise caution in assessing patient adherence using and changing the treatment plan based on those results. Urine drug testing, patient adherence, clinical toxicology, immunoassay, LC-MS, definitive drug testing, REMS, negative test results, false negative.

  13. Multicenter Evaluation of the AMPLICOR and Automated COBAS AMPLICOR CT/NG Tests for Detection of Chlamydia trachomatis

    PubMed Central

    Van Der Pol, Barbara; Quinn, Thomas C.; Gaydos, Charlotte A.; Crotchfelt, Kimberly; Schachter, Julius; Moncada, Jeanne; Jungkind, D.; Martin, David H.; Turner, Buffy; Peyton, Cynthia; Jones, Robert B.

    2000-01-01

    The fully automated COBAS AMPLICOR CT/NG and semiautomated AMPLICOR CT/NG tests were evaluated in a multicenter trial for the ability to detect Chlamydia trachomatis infections. Test performance compared to that of culture was evaluated for 2,236 matched endocervical swab and urine specimens obtained from women and for 1,940 matched urethral swab and urine specimens obtained from men. Culture-negative, PCR-positive specimens that tested positive in a direct fluorescent-antibody test or in a confirmatory PCR test for an alternative target sequence were resolved as true positives. The overall prevalences of chlamydia were 2.4% in women and 7.2% in men. The COBAS AMPLICOR and AMPLICOR formats yielded concordant results for 98.1% of the specimens. With the infected patient as the reference standard, the resolved sensitivities of COBAS AMPLICOR were 89.7% for endocervical swab specimens, 89.2% for female urine specimens, 88.6% for male urethral swab specimens, and 90.3% for male urine specimens. When results were analyzed as if only a single test had been performed on a single specimen type, the resolved sensitivity was always higher. The resolved specificities of PCR were 99.4% for endocervical swab specimens, 99.0% for female urine specimens, 98.7% for male urethral swab specimens, and 98.4% for male urine specimens. The internal control revealed that 2.4% of the specimens were inhibitory when initially tested. Nevertheless, valid results were obtained for 98.6% of the specimens because 59.1% of the inhibitory specimens were not inhibitory when a second aliquot was tested. The COBAS AMPLICOR and AMPLICOR CT/NG tests for C. trachomatis exhibited equally high sensitivity and specificity with both urogenital swab and urine specimens and thus are well suited for screening for C. trachomatis infection. PMID:10699004

  14. Point-of-care Helicobacter pylori urine antibody detection in a multi-ethnic adult population in the United States.

    PubMed

    Opekun, Antone R; Luu, Phong; Gotschall, Ann B; Abdalla, Nageeb; Torres, Elizabeth; Rudd, Summer B; Graham, David Y; Nurgalieva, Zhannat Z; Tsuchiya, Kyoko

    2006-07-01

    A need exists for accurate point-of-care tests for diagnosis of Helicobacter pylori (H. pylori) infection to evaluate a rapid urine-H. pylori antibody test device for detection of H. pylori infection in a point-of-care setting in the United States. A multi-center study in a multi-ethnic population compared the RAPIRUN urine antibody test with the (13)C-urea breath test (C-UBT) and a traditional serologic test, the high-molecular-weight cell-associated protein enzyme immunoassay (HM-CAP EIA). The primary comparator was with "definite positive" and "definite negative" patients defined as a concordance of combined results of the UBT and the HM-CAP IgG EIA. Overall, 188 eligible patients were enrolled (61 men, age range: 18-73 years, including 84 Hispanics, 73 Asian-Pacific Americans, 22 Black African-Americans, 6 non-Hispanic Caucasians, and 3 of "other" ethnicity). Compared with "definite positive" and "definite negative" results, the sensitivity and specificity of the urine antibody test were 0.9 and 1.0, respectively. The urine antibody test proved suitable for point-of-care rapid diagnosis of anti-H. pylori antibodies indicative of active or past H. pylori infection.

  15. Evaluation of a Urine Pooling Strategy for the Rapid and Cost-Efficient Prevalence Classification of Schistosomiasis.

    PubMed

    Lo, Nathan C; Coulibaly, Jean T; Bendavid, Eran; N'Goran, Eliézer K; Utzinger, Jürg; Keiser, Jennifer; Bogoch, Isaac I; Andrews, Jason R

    2016-08-01

    A key epidemiologic feature of schistosomiasis is its focal distribution, which has important implications for the spatial targeting of preventive chemotherapy programs. We evaluated the diagnostic accuracy of a urine pooling strategy using a point-of-care circulating cathodic antigen (POC-CCA) cassette test for detection of Schistosoma mansoni, and employed simulation modeling to test the classification accuracy and efficiency of this strategy in determining where preventive chemotherapy is needed in low-endemicity settings. We performed a cross-sectional study involving 114 children aged 6-15 years in six neighborhoods in Azaguié Ahoua, south Côte d'Ivoire to characterize the sensitivity and specificity of the POC-CCA cassette test with urine samples that were tested individually and in pools of 4, 8, and 12. We used a Bayesian latent class model to estimate test characteristics for individual POC-CCA and quadruplicate Kato-Katz thick smears on stool samples. We then developed a microsimulation model and used lot quality assurance sampling to test the performance, number of tests, and total cost per school for each pooled testing strategy to predict the binary need for school-based preventive chemotherapy using a 10% prevalence threshold for treatment. The sensitivity of the urine pooling strategy for S. mansoni diagnosis using pool sizes of 4, 8, and 12 was 85.9%, 79.5%, and 65.4%, respectively, when POC-CCA trace results were considered positive, and 61.5%, 47.4%, and 30.8% when POC-CCA trace results were considered negative. The modeled specificity ranged from 94.0-97.7% for the urine pooling strategies (when POC-CCA trace results were considered negative). The urine pooling strategy, regardless of the pool size, gave comparable and often superior classification performance to stool microscopy for the same number of tests. The urine pooling strategy with a pool size of 4 reduced the number of tests and total cost compared to classical stool microscopy. This study introduces a method for rapid and efficient S. mansoni prevalence estimation through examining pooled urine samples with POC-CCA as an alternative to widely used stool microscopy.

  16. Evaluation of a Urine Pooling Strategy for the Rapid and Cost-Efficient Prevalence Classification of Schistosomiasis

    PubMed Central

    Coulibaly, Jean T.; Bendavid, Eran; N’Goran, Eliézer K.; Utzinger, Jürg; Keiser, Jennifer; Bogoch, Isaac I.; Andrews, Jason R.

    2016-01-01

    Background A key epidemiologic feature of schistosomiasis is its focal distribution, which has important implications for the spatial targeting of preventive chemotherapy programs. We evaluated the diagnostic accuracy of a urine pooling strategy using a point-of-care circulating cathodic antigen (POC-CCA) cassette test for detection of Schistosoma mansoni, and employed simulation modeling to test the classification accuracy and efficiency of this strategy in determining where preventive chemotherapy is needed in low-endemicity settings. Methodology We performed a cross-sectional study involving 114 children aged 6–15 years in six neighborhoods in Azaguié Ahoua, south Côte d’Ivoire to characterize the sensitivity and specificity of the POC-CCA cassette test with urine samples that were tested individually and in pools of 4, 8, and 12. We used a Bayesian latent class model to estimate test characteristics for individual POC-CCA and quadruplicate Kato-Katz thick smears on stool samples. We then developed a microsimulation model and used lot quality assurance sampling to test the performance, number of tests, and total cost per school for each pooled testing strategy to predict the binary need for school-based preventive chemotherapy using a 10% prevalence threshold for treatment. Principal Findings The sensitivity of the urine pooling strategy for S. mansoni diagnosis using pool sizes of 4, 8, and 12 was 85.9%, 79.5%, and 65.4%, respectively, when POC-CCA trace results were considered positive, and 61.5%, 47.4%, and 30.8% when POC-CCA trace results were considered negative. The modeled specificity ranged from 94.0–97.7% for the urine pooling strategies (when POC-CCA trace results were considered negative). The urine pooling strategy, regardless of the pool size, gave comparable and often superior classification performance to stool microscopy for the same number of tests. The urine pooling strategy with a pool size of 4 reduced the number of tests and total cost compared to classical stool microscopy. Conclusions/Significance This study introduces a method for rapid and efficient S. mansoni prevalence estimation through examining pooled urine samples with POC-CCA as an alternative to widely used stool microscopy. PMID:27504954

  17. Utility of urine lipoarabinomannan (LAM) in diagnosing tuberculosis and predicting mortality with and without HIV: prospective TB cohort from the Thailand Big City TB Research Network.

    PubMed

    Suwanpimolkul, Gompol; Kawkitinarong, Kamon; Manosuthi, Weerawat; Sophonphan, Jiratchaya; Gatechompol, Sivaporn; Ohata, Pirapon June; Ubolyam, Sasiwimol; Iampornsin, Thatri; Katerattanakul, Pairaj; Avihingsanon, Anchalee; Ruxrungtham, Kiat

    2017-06-01

    To evaluate the applicability and accuracy of the urine lipoarabinomannan (LAM) test in tuberculosis (TB)/HIV co-infected patients and HIV-negative patients with disseminated TB. Frozen urine samples obtained at baseline from patients in the TB research cohort with proven culture-positive TB were selected for blinded urine LAM testing. One hundred and nine patients were categorized into four groups: (1) HIV-positive patients with TB; (2) HIV-negative patients with disseminated TB; (3) HIV-negative immunocompromised patients with TB; and (4) patients with diseases other than TB. The sensitivity of urine LAM testing for culture-positive TB, specificity of urine LAM testing for patients without TB, positive predictive value (PPV), and negative predictive value (NPV) were assessed. The sensitivity of the urine LAM test in group 1 patients with a CD4 T-cell count of >100, ≤100, and ≤50 cells/mm 3 was 38.5%, 40.6%, and 45%, respectively. The specificity and PPV of the urine LAM test were >80%. The sensitivity of the test was 20% in group 2 and 12.5% in group 3, and the specificity and PPV were 100% for both groups. A positive urine LAM test result was significantly associated with death. This promising diagnostic tool could increase the yield of TB diagnosis and may predict the mortality rate of TB infection, particularly in TB/HIV co-infected patients. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  18. Urine Toxicology in Adults Evaluated for a Central Hypersomnia and How the Results Modify the Physician's Diagnosis.

    PubMed

    Kosky, Christopher A; Bonakis, Anastasios; Yogendran, Arthee; Hettiarachchi, Gihan; Dargan, Paul I; Williams, Adrian J

    2016-11-15

    Drugs and psychoactive substances can cause sleepiness and when undetected, may lead to over diagnosis of central hypersomnias. We performed urine drug testing using gas chromatography-mass spectrometry in adults undergoing multiple sleep latency testing (MSLT) for a suspected central hypersomnia. We examined how the drug test results modified the treating physician's diagnosis. One hundred eighty-six consecutive patients with a suspected central hypersomnia who underwent clinical assessment, MSLT and urine drug testing by gas chromatography-mass spectrometry were retrospectively studied. Physicians made a diagnosis after clinical assessment and MSLT and were initially blinded to the urine drug test results. A third of patients assessed for subjective hypersomnia had a positive urine drug test for a substance affecting sleep. Opioids, cannabis, and amphetamines were the commonest drugs detected. Using MSLT, 35 (18.8%) of 186 patients had objective hypersomnia that may have been due to a drug or substance. Drugs or substances may have confounded the MSLT in 11 (20.1%) of 53 patients who fulfilled diagnostic criteria for idiopathic hypersomnia, and 12 (52%) of 23 of those who fulfilled diagnostic criteria for narcolepsy without cataplexy. Of the 75 positive urine drug samples, 61 (81%) were substances or medications not revealed in the physician interview. The treating physician had not suspected drugs or substances as a possible cause of objective hypersomnia in 34 (97%) of the 35 patients. Drugs and psychoactive substances can confound the results of the MSLT and when undetected could lead to over diagnosis of central hypersomnias. © 2016 American Academy of Sleep Medicine

  19. Use of a midstream clean catch mobile application did not lower urine contamination rates in an ED.

    PubMed

    Jacob, Mary S; Kulie, Paige; Benedict, Cameron; Ordoobadi, Alexander J; Sikka, Neal; Steinmetz, Erika; McCarthy, Melissa L

    2018-01-01

    Urine microscopy is a common test performed in emergency departments (EDs). Urine specimens can easily become contaminated by different factors, including the collection method. The midstream clean-catch (MSCC) collection technique is commonly used to reduce urine contamination. The urine culture contamination rate from specimens collected in our ED is 30%. We developed an instructional application (app) to show ED patients how to provide a MSCC urine sample. We hypothesized that ED patients who viewed our instructional app would have significantly lower urine contamination rates compared to patients who did not. We prospectively enrolled 257 subjects with a urinalysis and/or urine culture test ordered in the ED and asked them to watch our MSCC instructional app. After prospective enrollment was complete, we retrospectively matched each enrolled subject to an ED patient who did not watch the instructional app. Controls were matched to cases based on gender, type of urine specimen provided, ED visit date and shift. Urinalysis and urine culture contamination results were compared between the matched pairs using McNemar's test. The overall urine culture contamination rate of the 514 subjects was 38%. The majority of the matched pairs had a urinalysis (63%) or urinalysis plus urine culture (35%) test done. There were no significant differences in our urine contamination rates between the matched pairs overall or when stratified by gender, by prior knowledge of the clean catch process or by type of urine specimen. We did not see a lower contamination rate for patients who viewed our instructional app compared to patients who did not. It is possible that MSCC is not effective for decreasing urine specimen contamination. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Oral Fluid vs. Urine Analysis to Monitor Synthetic Cannabinoids and Classic Drugs Recent Exposure.

    PubMed

    Blandino, Vincent; Wetzel, Jillian; Kim, Jiyoung; Haxhi, Petrit; Curtis, Richard; Concheiro, Marta

    2017-01-01

    Urine is a common biological sample to monitor recent drug exposure, and oral fluid is an alternative matrix of increasing interest in clinical and forensic toxicology. Limited data are available about oral fluid vs. urine drug disposition, especially for synthetic cannabinoids. To compare urine and oral fluid as biological matrices to monitor recent drug exposure among HIV-infected homeless individuals. Seventy matched urine and oral fluid samples were collected from 13 participants. Cannabis, amphetamines, benzodiazepines, cocaine and opiates were analyzed in urine by the enzyme-multipliedimmunoassay- technique and in oral fluid by liquid chromatography tandem mass spectrometry (LCMSMS). Eleven synthetic cannabinoids were analyzed in urine and in oral fluid by LC-MSMS. Five oral fluid samples were positive for AB-FUBINACA. In urine, 4 samples tested positive for synthetic cannabinoids PB-22, 5-Fluoro-PB-22, AB-FUBINACA, and metabolites UR-144 5-pentanoic acid and UR-144 4-hydroxypentyl. In only one case, oral fluid and urine results matched, both specimens being AB-FUBINACA positive. For cannabis, 40 samples tested positive in urine and 30 in oral fluid (85.7% match). For cocaine, 37 urine and 52 oral fluid samples were positive (75.7% match). Twenty-four urine samples were positive for opiates, and 25 in oral fluid (81.4% match). For benzodiazepines, 23 samples were positive in urine and 25 in oral fluid (85.7% match). These results offer new information about drugs disposition between urine and oral fluid. Oral fluid is a good alternative matrix to urine for monitoring cannabis, cocaine, opiates and benzodiazepines recent use; however, synthetic cannabinoids showed mixed results. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  1. Quantitative urine confirmatory testing for synthetic cannabinoids in randomly collected urine specimens

    PubMed Central

    Castaneto, Marisol S.; Scheidweiler, Karl B.; Gandhi, Adarsh; Wohlfarth, Ariane; Klette, Kevin L.; Martin, Thomas M.; Huestis, Marilyn A.

    2014-01-01

    Synthetic cannabinoid intake is an ongoing health issue worldwide, with new compounds continually emerging, making drug testing complex. Parent synthetic cannabinoids are rarely detected in urine, the most common matrix employed in workplace drug testing. Optimal identification of synthetic cannabinoid markers in authentic urine specimens and correlation of metabolite concentrations and toxicities would improve synthetic cannabinoid result interpretation. We screened 20,017 randomly collected US military urine specimens between July 2011 and June 2012 with a synthetic cannabinoid immunoassay yielding 1,432 presumptive positive specimens. We analyzed all presumptive positive and 1,069 negative specimens with our qualitative synthetic cannabinoid LC-MS/MS method, which confirmed 290 positive specimens. All 290 positive and 487 randomly-selected negative specimens were quantified with the most comprehensive urine quantitative LC-MS/MS method published to date. 290 specimens confirmed positive for 22 metabolites from 11 parent synthetic cannabinoids. The five most predominant metabolites were JWH-018 pentanoic acid (93%), JWH-018 N-hydroxypentyl (84%), AM2201 N-hydroxypentyl (69%), JWH-073 butanoic acid (69%), and JWH-122 N-hydroxypentyl (45%) with 11.1 (0.1–2434), 5.1 (0.1–1239), 2.0 (0.1–321), 1.1 (0.1–48.6), and 1.1 (0.1–250) μg/L median (range) concentrations, respectively. Alkyl hydroxy and carboxy metabolites provided suitable biomarkers for 11 parent synthetic cannabinoids; although, hydroxyindoles also were observed. This is by far the largest data set of synthetic cannabinoid metabolites urine concentrations from randomly collected workplace drug testing specimens rather than acute intoxications or driving under the influence of drugs. These data improve the interpretation of synthetic cannabinoid urine test results and suggest suitable urine markers of synthetic cannabinoid intake. PMID:25231213

  2. Urine Creatinine Concentrations in Drug Monitoring Participants and Hospitalized Patients.

    PubMed

    Love, Sara A; Seegmiller, Jesse C; Kloss, Julie; Apple, Fred S

    2016-10-01

    Urine drug testing is commonly performed in both clinical and forensic arenas for screening, monitoring and compliance purposes. We sought to determine if urine creatinine concentrations in monitoring program participants were significantly different from hospital in-patients and out-patients undergoing urine drug testing. We retrospectively reviewed urine creatinine submitted in June through December 2015 for all specimens undergoing urine drug testing. The 20,479 creatinine results were categorized as hospitalized patients (H) and monitoring/compliance groups for pain management (P), legal (L) or recovery (R). Median creatinine concentrations (interquartile range, mg/dL) were significantly different (P < 0.001) between groups: H 126 (122-136); P 138 (137-143); L 147 (144-154); R 95 (92-97). In the two groups subject to on-demand sampling time pressures, median creatinine concentrations were significantly lower in the R vs. L group (P<0.001). In conclusion, recovery (R) participants have more dilute specimens, reflected by significantly lower creatinine concentration and may indicate participants' attempts to tamper with their drug test results through dilution means. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Study on color difference estimation method of medicine biochemical analysis

    NASA Astrophysics Data System (ADS)

    Wang, Chunhong; Zhou, Yue; Zhao, Hongxia; Sun, Jiashi; Zhou, Fengkun

    2006-01-01

    The biochemical analysis in medicine is an important inspection and diagnosis method in hospital clinic. The biochemical analysis of urine is one important item. The Urine test paper shows corresponding color with different detection project or different illness degree. The color difference between the standard threshold and the test paper color of urine can be used to judge the illness degree, so that further analysis and diagnosis to urine is gotten. The color is a three-dimensional physical variable concerning psychology, while reflectance is one-dimensional variable; therefore, the estimation method of color difference in urine test can have better precision and facility than the conventional test method with one-dimensional reflectance, it can make an accurate diagnose. The digital camera is easy to take an image of urine test paper and is used to carry out the urine biochemical analysis conveniently. On the experiment, the color image of urine test paper is taken by popular color digital camera and saved in the computer which installs a simple color space conversion (RGB -> XYZ -> L *a *b *)and the calculation software. Test sample is graded according to intelligent detection of quantitative color. The images taken every time were saved in computer, and the whole illness process will be monitored. This method can also use in other medicine biochemical analyses that have relation with color. Experiment result shows that this test method is quick and accurate; it can be used in hospital, calibrating organization and family, so its application prospect is extensive.

  4. [USING URINARY STRIPS].

    PubMed

    Barbeito García, Ana; Sampayo Montenegro, Ana

    2015-10-01

    Urinalysis using reactive strip is a commonly used in clinical practice. Although mainly indicated as first step test when a urine infection it suspected, it may also be a helpful tool in the management of a wide range of disorders. Standard urine test strips may comprise of up to 10 different chemical pads or reagents (leukocytes, nitrites, pH, glucose, proteins, ketones, bilirubin, urobilinogen, density and blood) that allow a qualitative and semiquantitative analysis of a urine sample. The test method consists of immersing the strip completely in a well-mixed sample of urine and left to stand for the time necessary for the reactions to occur (which is variable depending on the manufacturer). Finally the colors that appear are compared against a specific chromatic scale provided. Several factors may influence the results causing a significant number of false positives and negatives. Such limitations should always be taken into account when reading the test. Despite clinical features lead to the suspicion of an infection, urine test strips is a fast screening test that may reinforce the diagnosis. The combination of dysuria, frequency and emergency, hematuria, pain and sensibility in the pelvis reaches a positive predictive value to identified a urine infection of 90 %. When only dysuria and emergency or high frequency are present, the such probability diminishes to 70-80%, and, when dysuria is the only symptom, it drops to 25%. Despite urine test strips is a fast, easy and cheap method for the diagnosis and follow-up of several diseases, results are fairly heterogeneous and may be influenced by external factors. Therefore a cautious interpretation if advised. Sensibility and specificity of urine test strips is widely variable (S 46%-86% and E 17%-93%). Although the highest diagnostic values are obtained at primary care centers, where such tests are routinely used in a diverse population, the number of false positives is still high. This issue should be taken into account and a proper differential diagnosis of a positive result is mandatory in all cases. More studies are needed to assess the real sensibility and specificity of urinary reactive strips.

  5. [Delayed testing for the diagnosis of fungi in the urines. Evaluation of the BD Vacutainer C&S tubes for the storage of urine samples at room temperature].

    PubMed

    Baixench, M T; Al-Sheikh, M; Paugam, A

    2005-01-01

    The study included 37 urine samples which have been artificially infected with low levels (10(3) CFU/mL) of various fungi strains. We compared the effects of sample storage, up to 48 hours, at room temperature, in a urine evacuated tube containing specific additives with storage at + 4 degrees C, for the same length of time, in a urine evacuated tube without any additives. There have been no differences of results (speed of growth and colony size) between the 2 modes of storage. However, the experience has shown that samples needed a careful mixing before seeding to avoid underdetection of the strains. Based on the study results, the BD Vacutainer C&S tubes are suitable for delayed testing for the diagnosis of urine fungal infection.

  6. Rational use and interpretation of urine drug testing in chronic opioid therapy.

    PubMed

    Reisfield, Gary M; Salazar, Elaine; Bertholf, Roger L

    2007-01-01

    Urine drug testing (UDT) has become an essential feature of pain management, as physicians seek to verify adherence to prescribed opioid regimens and to detect the use of illicit or unauthorized licit drugs. Results of urine drug tests have important consequences in regard to therapeutic decisions and the trust between physician and patient. However, reliance on UDT to confirm adherence can be problematic if the results are not interpreted correctly, and evidence suggests that many physicians lack an adequate understanding of the complexities of UDT and the factors that can affect test results. These factors include metabolic conversion between drugs, genetic variations in drug metabolism, the sensitivity and specificity of the analytical method for a particular drug or metabolite, and the effects of intentional and unintentional interferants. In this review, we focus on the technical features and limitations of analytical methods used for detecting drugs or their metabolites in urine, the statistical constructs that are pertinent to ordering UDT and interpreting test results, and the application of these concepts to the clinical monitoring of patients maintained on chronic opioid therapy.

  7. Dipstick screening for urinary tract infection in febrile infants.

    PubMed

    Glissmeyer, Eric W; Korgenski, E Kent; Wilkes, Jacob; Schunk, Jeff E; Sheng, Xiaoming; Blaschke, Anne J; Byington, Carrie L

    2014-05-01

    This study compares the performance of urine dipstick alone with urine microscopy and with both tests combined as a screen for urinary tract infection (UTI) in febrile infants aged 1 to 90 days. We queried the Intermountain Healthcare data warehouse to identify febrile infants with urine dipstick, microscopy, and culture performed between 2004 and 2011. UTI was defined as >50 000 colony-forming units per milliliter of a urinary pathogen. We compared the performance of urine dipstick with unstained microscopy or both tests combined ("combined urinalysis") to identify UTI in infants aged 1 to 90 days. Of 13 030 febrile infants identified, 6394 (49%) had all tests performed and were included in the analysis. Of these, 770 (12%) had UTI. Urine culture results were positive within 24 hours in 83% of UTIs. The negative predictive value (NPV) was >98% for all tests. The combined urinalysis NPV was 99.2% (95% confidence interval: 99.1%-99.3%) and was significantly greater than the dipstick NPV of 98.7% (98.6%-98.8%). The dipstick positive predictive value was significantly greater than combined urinalysis (66.8% [66.2%-67.4%] vs 51.2% [50.6%-51.8%]). These data suggest 8 febrile infants would be predicted to have a false-positive combined urinalysis for every 1 infant with UTI initially missed by dipstick screening. Urine dipstick testing compares favorably with both microscopy and combined urinalysis in febrile infants aged 1 to 90 days. The urine dipstick test may be an adequate stand-alone screen for UTI in febrile infants while awaiting urine culture results. Copyright © 2014 by the American Academy of Pediatrics.

  8. Comparison of initial stream urine samples and cervical samples for detection of human papillomavirus.

    PubMed

    Hagihara, Mao; Yamagishi, Yuka; Izumi, Koji; Miyazaki, Narimi; Suzuki, Takayoshi; Kato, Hideo; Nishiyama, Naoya; Koizumi, Yusuke; Suematsu, Hiroyuki; Mikamo, Hiroshige

    2016-08-01

    Uterine cervical cancer is a treatable and preventable cancer. Medical efforts to reduce rates of cervical cancer focus on the promotion of human papillomavirus (HPV) vaccination and the promotion of routine cervical cancer screening done by cervical cytology and cervical HPV testing. Urine-based HPV testing would be simple and noninvasive approach to screen for cervical cancer. Two biospecimens (clinician-taken sample from cervix and initial stream urine sample) were provided from a total of 240 healthy women attending for cancer screening provided for HPV testing. We have assessed the HPV detection rates among cervical samples and pellet fraction of urine samples using HPV test (Anyplex™ II HPV28 Detection kit, Seegene, Korea). Among 240 samples screened, HPV prevalence was 42.9% in pellet fractions of urine samples. The agreement between the two kinds of samples was 98.4%, k = 0.792. Discordant results were observed in 27 cases; 5 were positive only by urine samples and 22 were positive only by smear samples. Sensitivity and specificity for all HPV DNA in pellet fractions of urine using cervical samples as reference was 68.4% and 99.9%. Comparing methodologies of collection of samples for HPV detection, they showed the higher agreements for almost genotypes between cervical samples and pellet fractions of urine samples. These results suggest that urine could be a good noninvasive tool to monitor HPV infection in women. Additional research in a larger and general screening population would be needed. Copyright © 2016 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  9. Cost and Efficacy Assessment of an Alternative Medication Compliance Urine Drug Testing Strategy.

    PubMed

    Doyle, Kelly; Strathmann, Frederick G

    2017-02-01

    This study investigates the frequency at which quantitative results provide additional clinical benefit compared to qualitative results alone. A comparison between alternative urine drug screens and conventional screens including the assessment of cost-to-payer differences, accuracy of prescription compliance or polypharmacy/substance abuse was also included. In a reference laboratory evaluation of urine specimens from across the United States, 213 urine specimens with provided prescription medication information (302 prescriptions) were analyzed by two testing algorithms: 1) conventional immunoassay screen with subsequent reflexive testing of positive results by quantitative mass spectrometry; and 2) a combined immunoassay/qualitative mass-spectrometry screen that substantially reduced the need for subsequent testing. The qualitative screen was superior to immunoassay with reflex to mass spectrometry in confirming compliance per prescription (226/302 vs 205/302), and identifying non-prescription abuse (97 vs 71). Pharmaceutical impurities and inconsistent drug metabolite patterns were detected in only 3.8% of specimens, suggesting that quantitative results have limited benefit. The percentage difference between the conventional testing algorithm and the alternative screen was projected to be 55%, and a 2-year evaluation of test utilization as a measure of test order volume follows an exponential trend for alternative screen test orders over conventional immunoassay screens that require subsequent confirmation testing. Alternative, qualitative urine drug screens provide a less expensive, faster, and more comprehensive evaluation of patient medication compliance and drug abuse. The vast majority of results were interpretable with qualitative results alone indicating a reduced need to automatically reflex to quantitation or provide quantitation for the majority of patients. This strategy highlights a successful approach using an alternative strategy for both the laboratory and physician to align clinical needs while being mindful of costs.

  10. Urinalysis in children and adolescents.

    PubMed

    Utsch, Boris; Klaus, Günter

    2014-09-12

    Urinalysis is the most commonly performed biochemical test in infancy and early childhood. The urine sample should be correctly obtained, age-specific aspects should be considered, and age-dependent reference values should be used. This review is based on a selective literature search in electronic databases, textbooks, and guidelines from Germany and abroad on the acquisition of urine samples and the performance of urinalysis in infancy and early childhood. The timing and mode of acquisition of the urine sample affect the assessment of hematuria, proteinuria, leukocyturia, nitrituria, and the uropathogenic bacterial colony count in the urine culture. Dipstick tests can be used for targeted screening for these features. The test results should be interpreted together with the findings of urine microscopy, the medical history, and the physical examination. Proteinuria should be quantified and differentiated; both of these things can be done either from collected urine or (especially in infants and young children) from a spontaneously voided urine sample, by determination of the protein/creatinine quotient. Orthostatic proteinuria in an adolescent requires no further evaluation or treatment. Hematuria should be characterized as either glomerular or non-glomerular erythrocyturia. Asymptomatic, isolated microhematuria in childhood is not uncommon and often transient; in the absence of a family history, it usually does not require an extensive work-up. Proteinuria combined with hematuria should arouse the suspicion of glomerulonephritis. Urinalysis in infancy and early childhood is a simple and informative diagnostic test as long as the urine sample has been obtained properly and the results are interpreted appropriately for this age group.

  11. HCG in urine

    MedlinePlus

    Beta-HCG - urine; Human chorionic gonadotropin - urine; Pregnancy test - hCG in urine ... To collect a urine sample, you urinate into a special (sterile) cup. Home pregnancy tests require the test strip to be dipped into ...

  12. Adulteration of urine by "Urine Luck".

    PubMed

    Wu, A H; Bristol, B; Sexton, K; Cassella-McLane, G; Holtman, V; Hill, D W

    1999-07-01

    In vitro adulterants are used to invalidate assays for urine drugs of abuse. The present study examined the effect of pyridinium chlorochromate (PCC) found in the product "Urine Luck". PCC was prepared and added to positive urine controls at concentrations of 0, 10, 50, and 100 g/L. The controls were assayed for methamphetamine, benzoylecgonine (BE), codeine and morphine, tetrahydrocannabinol (THC), and phencyclidine (PCP) with the Emit II (Syva) and Abuscreen Online (Roche) immunoassays, and by gas chromatography/mass spectrometry (GC/MS). Two tests were also developed to detect PCC in urine: a spot test to detect chromate ions using 10 g/L 1,5-diphenylcarbazide as the indicator, and a GC/MS assay for pyridine. We tested 150 samples submitted for routine urinalysis, compliance, and workplace drug testing for PCC, using these assays. Response rates decreased at 100 g/L PCC for all Emit II drug assays and for the Abuscreen morphine and THC assays. In contrast, the Abuscreen amphetamine assay produced apparently higher results, and no effect was seen on the results for BE or PCP. The PCC did not affect the GC/MS recovery of methamphetamine, BE, PCP, or their deuterated internal standards, but decreased GC/MS recovery of the opiates at both intermediate (50 g/L) and high (100 g/L) PCC concentrations and apparent concentrations of THC and THC-d3 at all PCC concentrations. Two of 50 samples submitted for workplace drug testing under chain-of-custody conditions were positive for PCC, whereas none of the remaining 100 specimens submitted for routine urinalysis or compliance drug testing were positive. PCC is an effective adulterant for urine drug testing of THC and opiates. Identification of PCC use can be accomplished with use of a spot test for the oxidant.

  13. Urine test for HPV genotypes as a predictor of precancerous cervical lesions and for cervical cancer screening.

    PubMed

    Maged, Ahmed M; Saad, Hany; Salah, Emad; Meshaal, Hadeer; AbdElbar, Mostafa; Omran, Eman; Eldaly, Ashraf

    2018-06-01

    To assess the sensitivity of a urine test for high-risk HPV DNA genotypes in the detection of high-grade squamous intra-epithelial lesion (HSIL) and its correlation with pathologic precancerous lesions. The present prospective cross-sectional study included women referred to Kasr AlAiny Medical School, Cairo, Egypt, for cervical smear anomalies, a history of cervical smear anomalies, or for suspicious cervix between May 1, 2015, and April 30, 2017. Paired urine tests and cervical smears were performed. HPV DNA was detected in urine using polymerase chain reaction and cervical smears were performed with a cervical spatula and a cytobrush. Agreement between urine test results and pathology was examined. In total, 1375 women were included. Urine test for high-risk HPV DNA demonstrated 97.8% (95% confidence interval [CI] 92.1%-99.7%) sensitivity and 100% (95% CI 99.7%-100.0%) specificity for HSIL. Overall, 87 women had a positive urine test for high-risk HPV; of these, 82 (94.3%, 95% CI 87.1%-98.1%) had pathologic findings of cervical intra-epithelial neoplasia 2 or 3 (CIN2/3). Similarly, 89 women had HSIL cytology; again, 82 had CIN2/3 (92.1%; 95% CI, 84.3%-96.4%). There was good agreement between a positive urine test for high-risk HPV DNA genotypes and pathologic findings of CIN2/3. © 2018 International Federation of Gynecology and Obstetrics.

  14. Comparison of vacuum and non-vacuum urine tubes for urinary sediment analysis.

    PubMed

    Topcuoglu, Canan; Sezer, Sevilay; Kosem, Arzu; Ercan, Mujgan; Turhan, Turan

    2017-12-01

    Urine collection systems with aspiration system for vacuum tubes are becoming increasingly common for urinalysis, especially for microscopic examination of the urine. In this study, we aimed to examine whether vacuum aspiration of the urine sample has any adverse effect on sediment analysis by comparing results from vacuum and non-vacuum urine tubes. The study included totally 213 urine samples obtained from inpatients and outpatients in our hospital. Urine samples were collected to containers with aspiration system for vacuum tubes. Each sample was aliquoted to both vacuum and non-vacuum urine tubes. Urinary sediment analysis was performed using manual microscope. Results were evaluated using chi-square test. Comparison of the sediment analysis results from vacuum and non-vacuum urine tubes showed that results were highly concordant for erythrocyte, leukocyte and epithelial cells (gamma values 1, 0.997, and 0.994, respectively; p < .001). Results were also concordant for urinary casts, crystals and yeast (kappa values 0.815, 0.945 and 1, respectively; p < .001). The results show that in urinary sediment analysis, vacuum aspiration has no adverse effect on the cellular components except on casts.

  15. Automated color classification of urine dipstick image in urine examination

    NASA Astrophysics Data System (ADS)

    Rahmat, R. F.; Royananda; Muchtar, M. A.; Taqiuddin, R.; Adnan, S.; Anugrahwaty, R.; Budiarto, R.

    2018-03-01

    Urine examination using urine dipstick has long been used to determine the health status of a person. The economical and convenient use of urine dipstick is one of the reasons urine dipstick is still used to check people health status. The real-life implementation of urine dipstick is done manually, in general, that is by comparing it with the reference color visually. This resulted perception differences in the color reading of the examination results. In this research, authors used a scanner to obtain the urine dipstick color image. The use of scanner can be one of the solutions in reading the result of urine dipstick because the light produced is consistent. A method is required to overcome the problems of urine dipstick color matching and the test reference color that have been conducted manually. The method proposed by authors is Euclidean Distance, Otsu along with RGB color feature extraction method to match the colors on the urine dipstick with the standard reference color of urine examination. The result shows that the proposed approach was able to classify the colors on a urine dipstick with an accuracy of 95.45%. The accuracy of color classification on urine dipstick against the standard reference color is influenced by the level of scanner resolution used, the higher the scanner resolution level, the higher the accuracy.

  16. Asymptomatic bacteriuria in pregnant women attending Boo-Ali Hospital Tehran Iran: Urine analysis vs. urine culture

    PubMed Central

    Etminan-Bakhsh, Mina; Tadi, Sima; Darabi, Roksana

    2017-01-01

    Background Asymptomatic bacteriuria is one of the common problems in pregnancy. Asymptomatic bacteriuria is associated with pyelonephritis, preterm labor and low birth weight infants. The physiological and anatomical changes in pregnancy facilitate urinary tract infection (UTI) during pregnancy. Several tests are available for diagnosis of asymptomatic bacteriuria. The urine culture is a gold standard diagnostic test for asymptomatic bacteriuria but it is expensive and time-consuming. Screening methods may be useful in detecting high-risk pregnant women for asymptomatic bacteriuria. Objective The aim of the present study was to compare urine analysis as a rapid screening test to urine culture in diagnosis of asymptomatic bacteriuria. Methods A total of 123 pregnant women attending the obstetrics clinic of Boo-Ali hospital in Tehran, Iran from March 2013 to September 2014 were included in the present diagnostic cross-sectional study. One hundred twenty three mid-stream urine samples were inoculated into cultures and were processed by dipstick (nitrite test and leucocyte esterase test) and microscopic pus cell count. The sensitivity, specificity, positive predictive value and negative predictive value of nitrite test, leucocyte esterase test and microscopic pus cell count were compared with urine culture in diagnosis of asymptomatic bacteriuria by using SPSS version 19. Results Of 123 urine samples, significant asymptomatic bacteriuria (≥104 cfu/Ml) was detected in 8 (6.5%) subjects. The sensitivity and specificity of nitrite test were 37% and 100% respectively. The sensitivity of pus cell count alone and leucocyte esterase test alone were 100% but the specificity of them were 64% and 65% respectively. We found high negative predictive value by Pus cell count and the leucocyte esterase test (100%) and low positive predictive value by them (16% and 17% respectively). Conclusion Urine culture is the most useful test for diagnosis of asymptomatic bacteriuria. None of our screening tests had a sensitivity and specificity of 100%, whereas we can only refer the pregnant women with positive leucocyte esterase test and significant pyuria to the urine culture. PMID:29403616

  17. Accuracy of urinary human papillomavirus testing for presence of cervical HPV: systematic review and meta-analysis

    PubMed Central

    Pathak, Neha; Dodds, Julie; Khan, Khalid

    2014-01-01

    Objective To determine the accuracy of testing for human papillomavirus (HPV) DNA in urine in detecting cervical HPV in sexually active women. Design Systematic review and meta-analysis. Data sources Searches of electronic databases from inception until December 2013, checks of reference lists, manual searches of recent issues of relevant journals, and contact with experts. Eligibility criteria Test accuracy studies in sexually active women that compared detection of urine HPV DNA with detection of cervical HPV DNA. Data extraction and synthesis Data relating to patient characteristics, study context, risk of bias, and test accuracy. 2×2 tables were constructed and synthesised by bivariate mixed effects meta-analysis. Results 16 articles reporting on 14 studies (1443 women) were eligible for meta-analysis. Most used commercial polymerase chain reaction methods on first void urine samples. Urine detection of any HPV had a pooled sensitivity of 87% (95% confidence interval 78% to 92%) and specificity of 94% (95% confidence interval 82% to 98%). Urine detection of high risk HPV had a pooled sensitivity of 77% (68% to 84%) and specificity of 88% (58% to 97%). Urine detection of HPV 16 and 18 had a pooled sensitivity of 73% (56% to 86%) and specificity of 98% (91% to 100%). Metaregression revealed an increase in sensitivity when urine samples were collected as first void compared with random or midstream (P=0.004). Limitations The major limitations of this review are the lack of a strictly uniform method for the detection of HPV in urine and the variation in accuracy between individual studies. Conclusions Testing urine for HPV seems to have good accuracy for the detection of cervical HPV, and testing first void urine samples is more accurate than random or midstream sampling. When cervical HPV detection is considered difficult in particular subgroups, urine testing should be regarded as an acceptable alternative. PMID:25232064

  18. Urine test could become early detection device.

    PubMed

    1999-03-01

    Researchers at the Clinical Reference Laboratory in Kansas have detected HIV antibodies in the urine of 24 low-risk people who tested negative for HIV in blood tests. These people are presumed to have been exposed to the virus, but it is not known yet if they actually carry the infection. It is possible for the virus and its antibodies to appear in the urogenital tract before spreading to the bloodstream. If this is correct, the urine test could become a way to screen high-risk individuals, who as a result may be able to initiate highly active antiretroviral therapy (HAART) before the infection becomes systemic. Study results will be presented at the American Association of Clinical Chemists meeting.

  19. Glucose urine test

    MedlinePlus

    Urine sugar test; Urine glucose test; Glucosuria test; Glycosuria test ... After you provide a urine sample, it is tested right away. The health care provider uses a dipstick made with a color-sensitive pad. The ...

  20. Primary Care Providers’ Experiences with Urine Toxicology Tests to Manage Prescription Opioid Misuse and Substance Use Among Chronic Non-Cancer Pain Patients in Safety Net Healthcare Settings

    PubMed Central

    Ceasar, Rachel; Chang, Jamie; Zamora, Kara; Hurstak, Emily; Kushel, Margot; Miaskowski, Christine; Knight, Kelly

    2016-01-01

    Background Guideline recommendations to reduce prescription opioid misuse among patients with chronic non-cancer pain include the routine use of urine toxicology tests for high-risk patients. Yet little is known about how the implementation of urine toxicology tests among patients with co-occurring chronic non-cancer pain and substance use impacts primary care providers’ management of misuse. In this paper, we present clinicians’ perspectives on the benefits and challenges of implementing urine toxicology tests in the monitoring of opioid misuse and substance use in safety net healthcare settings. Methods We interviewed 23 primary care providers from six safety net healthcare settings whose patients had a diagnosis of co-occurring chronic non-cancer pain and substance use. We transcribed, coded, and analyzed interviews using grounded theory methodology. Results The benefits of implementing urine toxicology tests for primary care providers included less reliance on intuition to assess for misuse and the ability to identify unknown opioid misuse and/or substance use. The challenges of implementing urine toxicology tests included insufficient education and training about how to interpret and implement tests, and a lack of clarity on how and when to act on tests that indicated misuse and/or substance use. Conclusions These data suggest that primary care clinicians’ lack of education and training to interpret and implement urine toxicology tests may impact their management of patient opioid misuse and/or substance use. Clinicians may benefit from additional education and training about the clinical implementation and use of urine toxicology tests. Additional research is needed on how primary care providers implementation and use of urine toxicology tests impacts chronic non-cancer pain management in primary care and safety net healthcare settings among patients with co-occurring chronic non-cancer pain and substance use. PMID:26682471

  1. Results of an Aboriginal community-based renal disease management program incorporating point of care testing for urine albumin:creatinine ratio.

    PubMed

    Shephard, M D S; Allen, G G; Paizis, K; Barbara, J A J; Batterham, M; Vanajek, A

    2006-01-01

    There has been a significant increase in the burden of renal disease among Aboriginal Australians over the past 15 years. Urine albumin:creatinine ratio (ACR) is a well-established marker of microalbuminuria and can be conveniently performed on the DCA 2000 point-of-care testing (POCT) analyser (Bayer Australia; Melbourne, VIC, Australia) with an on-site result available in 7 min. The application of the urine ACR POCT for renal disease risk assessment was pioneered by our group in the Umoona Kidney Project. This article describes the results of the management arm of the Umoona Kidney Project, which used point-of-care urine ACR testing for the first time within a management framework to monitor albuminuria in patients at highest risk of renal disease. The article also examines the analytical quality of POCT results and overall community acceptance of the Umoona Kidney Project. Adults clinically assessed by Flinders Medical Centre renal specialists as being at greatest risk for renal disease were offered the ACE inhibitor (ACEI) perindopril on a voluntary basis. Selected renal markers, including POCT urine ACR (conducted on-site by Umoona's Aboriginal health worker team), plasma electrolytes, urea, creatinine, calculated glomerular filtration rate and blood pressure were measured six monthly. Regular quality control testing was undertaken to monitor the analytical performance of the POCT analyser. A culturally appropriate questionnaire was designed and implemented to assess community satisfaction with the project. In all, 231 patient management consultations were conducted over a two year period, with over 70% of patients having four or more (up to a maximum of eight) consultations; 35 patients (mean age 49.2 [+/-2.3] years, 54% males) participated voluntarily in the management arm. All were overtly hypertensive, hypertensive with other risk factors or had diabetes. The renal status of these patients was followed for a mean of 63 +/- 4.5 weeks. In total, 111 POCT urine ACR tests were performed for patient management (mean 3.2 tests per patient). There was no significant difference in POCT urine ACR in the study period with a median (and inter-quartile range) of 5.7 mg/mmol (1.2-15.2) pre-ACEI and 4.3 mg/mmol (1.3-16.7) post-ACEI treatment (p = 0.50, Wilcoxon signed ranks test). The calculated glomerular filtration rate altered from 110 to 118 mL/min (p = 0.019, paired t-test). There was no change in the group plasma potassium, urea and creatinine. Collectively these results indicate a stabilisation in renal function among the management group. Blood pressure (both lying and standing) fell significantly in the study period. The imprecision for urine ACR quality control POCT conducted during the management program was within nationally and internationally accepted precision goals for urine albumin, creatinine and ACR. Fifty community members completed the satisfaction questionnaire. Three-quarters of respondents felt there were no cultural barriers in providing a urine sample for urine ACR POCT. The management arm of the Umoona Kidney Project was effective in stabilising the renal function and improving the blood pressure of community members identified to be at greatest risk of kidney disease. POCT urine ACR testing can be utilised, not only for community risk assessment, but also for patient management. The Umoona Kidney Project was well accepted by the health service and community members.

  2. Urine Pretreatment Configuration and Test Results for Space Applications

    NASA Technical Reports Server (NTRS)

    Howard, Stanley G.; Hutchens, Cindy F.; Rethke, Donald W.; Swartley, Vernon L.; Marsh, Robert W.

    1998-01-01

    Pretreatment of urine using Oxone and sulfuric acid is baselined in the International Space Station (ISS) waste water reclamation system to control odors, fix urea and control microbial growth. In addition, pretreatment is recommended for long term flight use of urine collection and two phase separation to reduce or eliminate fouling of the associated hardware and plumbing with urine precipitates. This is important for ISS application because the amount of maintenance time for cleaning and repairing hardware must be minimized. This paper describes the development of a chemical pretreatment system based on solid tablet shapes which are positioned in the urine collection hose and are dissolved by the intrained urine at the proper ratio of pretreatment to urine. Building upon the prior success of the developed and tested solid Oxone tablet a trade study was completed to confirm if a similar approach, or alternative, would be appropriate for the sulfuric acid injection method. In addition, a recommended handling and packaging approach of the solid tablets for long term, safe and convenient use on ISS was addressed. Consequently, the solid tablet concept with suitable packaging was identified as the Urine Pretreat / Prefilter Assembly (UPPA). Testing of the UPPA configuration confirmed the disolution rates and ratios required by ISS were achieved. This testing included laboratory controlled methods as well as a 'real world' test evaluation that occurred during the 150 day Stage 10 Water Recovery Test (WRT) conducted at NASA Marshall Space Flight Center (MSFC).

  3. Fast screening tests for the simultaneous detection of 11 drugs of abuse in urine specimens. A forensic epidemiology study of 28,298 cases in Tunisia.

    PubMed

    Moslah, B; Araoud, M; Nouioui, M A; Najjar, S; Amira, D; Ben Salah, N; Hedhili, A

    2018-02-01

    Forensic investigation performed on people suspected to be drug abusers covering all Tunisian cities was conducted by monitoring an epidemiological study of human urine samples surveying positive rates of consumption for drugs of abuse. The forensic investigations were conducted on a total of 28,298 arrested individuals suspected to be drug addicts during five years (January 2010-December 2015). An immunoassay screening tests to detect elevated levels of drugs classes in urine samples was performed. These screening assays provide a preliminary qualitative test result. Only positives urine specimens were analyzed with GC-MS for confirmation. Except for cannabis, the results showed insignificant number of positive cases for cocaine, ecstasy (MDMA) and amphetamine consumptions (<1%). Copyright © 2017 Elsevier B.V. All rights reserved.

  4. [A study of biomechanical method for urine test based on color difference estimation].

    PubMed

    Wang, Chunhong; Zhou, Yue; Zhao, Hongxia; Zhou, Fengkun

    2008-02-01

    The biochemical analysis of urine is an important inspection and diagnosis method in hospitals. The conventional method of urine analysis covers mainly colorimetric visual appraisement and automation detection, in which the colorimetric visual appraisement technique has been superseded basically, and the automation detection method is adopted in hospital; moreover, the price of urine biochemical analyzer on market is around twenty thousand RMB yuan (Y), which is hard to enter into ordinary families. It is known that computer vision system is not subject to the physiological and psychological influence of person, its appraisement standard is objective and steady. Therefore, according to the color theory, we have established a computer vision system, which can carry through collection, management, display, and appraisement of color difference between the color of standard threshold value and the color of urine test paper after reaction with urine liquid, and then the level of an illness can be judged accurately. In this paper, we introduce the Urine Test Biochemical Analysis method, which is new and can be popularized in families. Experimental result shows that this test method is easy-to-use and cost-effective. It can realize the monitoring of a whole course and can find extensive applications.

  5. Results for the Brine Evaporation Bag (BEB) Brine Processing Test

    NASA Technical Reports Server (NTRS)

    Delzeit, Lance; Flynn, Michael; Fisher, John; Shaw, Hali; Kawashima, Brian; Beeler, David; Howard, Kevin

    2015-01-01

    The recent Brine Processing Test compared the NASA Forward Osmosis Brine Dewatering (FOBD), Paragon Ionomer Water Processor (IWP), UMPQUA Ultrasonic Brine Dewatering System (UBDS), and the NASA Brine Evaporation Bag (BEB). This paper reports the results of the BEB. The BEB was operated at 70 deg C and a base pressure of 12 torr. The BEB was operated in a batch mode, and processed 0.4L of brine per batch. Two different brine feeds were tested, a chromic acid-urine brine and a chromic acid-urine-hygiene mix brine. The chromic acid-urine brine, known as the ISS Alternate Pretreatment Brine, had an average processing rate of 95 mL/hr with a specific power of 5kWhr/L. The complete results of these tests will be reported within this paper.

  6. Does Performing Preplacement Workplace Hair Drug Testing Influence US Department of Transportation Random and Postaccident Urine Drug Test Positivity Rates?

    PubMed

    Price, James W

    Does performing pre-employment hair drug testing subsequently affect the prevalence of positive random and postaccident urine drug tests? This cross-sectional study was designed to evaluate the prevalence of positive postaccident and random workplace urine drug tests for companies that perform pre-employment hair and urine drug testing to companies that only perform pre-employment urine drug testing. Fisher exact test of independence indicated no significant difference between pre-employment hair drug testing and overall US Department of Transportation random and postaccident urine drug test positivity rates. The analysis failed to reject the null hypothesis, suggesting that pre-employment hair drug testing had no effect upon random and postaccident urine drug test positivity rates.

  7. Cross-reactivity of stimulants found in sports drug testing by two fluorescence polarization immunoassays.

    PubMed

    de la Torre, R; Badia, R; Gonzàlez, G; García, M; Pretel, M J; Farré, M; Segura, J

    1996-01-01

    We investigated the usefulness of immunological methods for presumptive detection of stimulants found in sports drug testing. The ingestion of substances that show no cross-reactivity in tests commercially available for the detection of amphetamines can produce positive results in the urine. Human metabolism contributes to the positive results of some urine samples when the parent compound does not cross-react with the antibodies of the assay. Urine samples from healthy volunteers given stimulants were tested by chromatographic methods and by two different fluorescence polarization immunoassays (FPIA) from Abbott Laboratories for the analysis of amphetamines. According to the results obtained, we classified stimulants into four groups: detectable stimulants that gave rise to amphetamine by human metabolism (group 1); detectable ephedrines and related compounds, appearing in the urine either as parent compounds or originated by metabolism (group 2); detectable stimulants that displayed actual cross-reactivity with amphetamine tests (group 3); and stimulants not detected by FPIA (group 4). Most of the true doping cases due to the ingestion of stimulants may be detected by FPIA. The specificity of the results may be increased by combining immunological assays with different antibodies.

  8. Diagnostic accuracy of a point-of-care urine test for tuberculosis screening among newly-diagnosed HIV-infected adults: a prospective, clinic-based study.

    PubMed

    Drain, Paul K; Losina, Elena; Coleman, Sharon M; Giddy, Janet; Ross, Douglas; Katz, Jeffrey N; Walensky, Rochelle P; Freedberg, Kenneth A; Bassett, Ingrid V

    2014-02-26

    A rapid diagnostic test for active tuberculosis (TB) at the clinical point-of-care could expedite case detection and accelerate TB treatment initiation. We assessed the diagnostic accuracy of a rapid urine lipoarabinomannan (LAM) test for TB screening among HIV-infected adults in a TB-endemic setting. We prospectively enrolled newly-diagnosed HIV-infected adults (≥18 years) at 4 outpatient clinics in Durban from Oct 2011-May 2012, excluding those on TB therapy. A physician evaluated all participants and offered CD4 cell count testing. Trained study nurses collected a sputum sample for acid-fast bacilli smear microscopy (AFB) and mycobacterial culture, and performed urine LAM testing using Determine™ TB LAM in the clinic. The presence of a band regardless of intensity on the urine LAM test was considered positive. We defined as the gold standard for active pulmonary TB a positive sputum culture for Mycobacterium tuberculosis. Diagnostic accuracy of urine LAM was assessed, alone and in combination with smear microscopy, and stratified by CD4 cell count. Among 342 newly-diagnosed HIV-infected participants, 190 (56%) were male, mean age was 35.6 years, and median CD4 was 182/mm3. Sixty participants had culture-positive pulmonary TB, resulting in an estimated prevalence of 17.5% (95% CI 13.7-22.0%). Forty-five (13.2%) participants were urine LAM positive. Mean time from urine specimen collection to LAM test result was 40 minutes (95% CI 34-46 minutes). Urine LAM test sensitivity was 28.3% (95% CI 17.5-41.4) overall, and 37.5% (95% CI 21.1-56.3) for those with CD4 count <100/mm3, while specificity was 90.1% (95% CI 86.0-93.3) overall, and 86.9% (95% CI 75.8-94.2) for those with CD4 < 100/mm3. When combined with sputum AFB (either test positive), sensitivity increased to 38.3% (95% CI 26.0-51.8), but specificity decreased to 85.8% (95% CI 81.1-89.7). In this prospective, clinic-based study with trained nurses, a rapid urine LAM test had low sensitivity for TB screening among newly-diagnosed HIV-infected adults, but improved sensitivity when combined with sputum smear microscopy.

  9. Urine Pretreat Injection System

    NASA Technical Reports Server (NTRS)

    1995-01-01

    A new method of introducing the OXONE (Registered Trademark) Monopersulfate Compound for urine pretreat into a two-phase urine/air flow stream has been successfully tested and evaluated. The feasibility of this innovative method has been established for purposes of providing a simple, convenient, and safe method of handling a chemical pretreat required for urine processing in a microgravity space environment. Also, the Oxone portion of the urine pretreat has demonstrated the following advantages during real time collection of 750 pounds of urine in a Space Station design two-phase urine Fan/Separator: Eliminated urine precipitate buildup on internal hardware and plumbing; Minimized odor from collected urine; and Virtually eliminated airborne bacteria. The urine pretreat, as presently defined for the Space Station program for proper downstream processing of urine, is a two-part chemical treatment of 5.0 grams of Oxone and 2.3 ml of H2SO4 per liter of urine. This study program and test demonstrated only the addition of the proper ratio of Oxone into the urine collection system upstream of the Fan/Separator. This program was divided into the following three major tasks: (1) A trade study, to define and recommend the type of Oxone injection method to pursue further; (2) The design and fabrication of the selected method; and (3) A test program using high fidelity hardware and fresh urine to demonstrate the method feasibility. The trade study was conducted which included defining several methods for injecting Oxone in different forms into a urine system. Oxone was considered in a liquid, solid, paste and powered form. The trade study and the resulting recommendation were presented at a trade study review held at Hamilton Standard on 24-25 October 94. An agreement was reached at the meeting to continue the solid tablet in a bag concept which included a series of tablets suspended in the urine/air flow stream. These Oxone tablets would slowly dissolve at a controlled rate providing the proper concentration in the collected urine. To implement the solid tablet in a bag approach, a design concept was completed with prototype drawings of the complete urine pretreat prefilter assembly. A successful fabrication technique was developed for retaining the Oxone tablets in a fabric casing attached to the end of the existing Space Station Waste Collection System urine prefilter assembly. The final pretreat prefilter configuration held sufficient Oxone in a tablet form to allow normal scheduled daily (or twice daily) change out of the urine filter depending on the use rate of the Space Station urine collection system. The actual tests to prove the concept were conducted using the Urine Fan/Separator assembly that was originally used in the STS-52 Design Test Objective (DTO) urinal assembly. Other related tests were conducted to demonstrate the actual minimum ratio of Oxone to urine that will control microbial growth.

  10. Performing a urine dipstick test with a clean-catch urine sample is an accurate screening method for urinary tract infections in young infants.

    PubMed

    Herreros, María Luisa; Tagarro, Alfredo; García-Pose, Araceli; Sánchez, Aida; Cañete, Alfonso; Gili, Pablo

    2018-01-01

    This study evaluated using urine dipstick tests with the clean-catch method to screen for urinary tract infection (UTI) in febrile infants under 90 days of age. We carried out a comparative diagnostic accuracy study of infants under 90 days old, who were studied for unexplained fever without any source, in the emergency room of a hospital in Madrid from January 2011 to January 2013. We obtained matched samples of urine using two different methods: a clean-catch, standardised stimulation technique and catheterisation collection. The results of the leucocyte esterase test and nitrite test were compared with their urine cultures. We obtained 60 pairs of matched samples. A combined analysis of leukocyte esterase and, or, nitrites yielded a sensitivity of 86% and a specificity of 80% for the diagnosis of UTIs in clean-catch samples. The sensitivity of leukocyte esterase and, or, nitrites in samples obtained by catheterisation were not statistically different to the clean-catch samples (p = 0.592). Performing urine dipstick tests using urine samples obtained by the clean-catch method was an accurate screening test for diagnosing UTIs in febrile infants of less than 90 days old. This provided a good alternative to bladder catheterisation when screening for UTIs. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  11. Quantitative urine confirmatory testing for synthetic cannabinoids in randomly collected urine specimens.

    PubMed

    Castaneto, Marisol S; Scheidweiler, Karl B; Gandhi, Adarsh; Wohlfarth, Ariane; Klette, Kevin L; Martin, Thomas M; Huestis, Marilyn A

    2015-06-01

    Synthetic cannabinoid intake is an ongoing health issue worldwide, with new compounds continually emerging, making drug testing complex. Parent synthetic cannabinoids are rarely detected in urine, the most common matrix employed in workplace drug testing. Optimal identification of synthetic cannabinoid markers in authentic urine specimens and correlation of metabolite concentrations and toxicities would improve synthetic cannabinoid result interpretation. We screened 20 017 randomly collected US military urine specimens between July 2011 and June 2012 with a synthetic cannabinoid immunoassay yielding 1432 presumptive positive specimens. We analyzed all presumptive positive and 1069 negative specimens with our qualitative synthetic cannabinoid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method, which confirmed 290 positive specimens. All 290 positive and 487 randomly selected negative specimens were quantified with the most comprehensive urine quantitative LC-MS/MS method published to date; 290 specimens confirmed positive for 22 metabolites from 11 parent synthetic cannabinoids. The five most predominant metabolites were JWH-018 pentanoic acid (93%), JWH-N-hydroxypentyl (84%), AM2201 N-hydroxypentyl (69%), JWH-073 butanoic acid (69%), and JWH-122 N-hydroxypentyl (45%) with 11.1 (0.1-2,434), 5.1 (0.1-1,239), 2.0 (0.1-321), 1.1 (0.1-48.6), and 1.1 (0.1-250) µg/L median (range) concentrations, respectively. Alkyl hydroxy and carboxy metabolites provided suitable biomarkers for 11 parent synthetic cannabinoids; although hydroxyindoles were also observed. This is by far the largest data set of synthetic cannabinoid metabolites urine concentrations from randomly collected workplace drug testing specimens rather than acute intoxications or driving under the influence of drugs. These data improve the interpretation of synthetic cannabinoid urine test results and suggest suitable urine markers of synthetic cannabinoid intake. This article is a U.S. Government work and is in the public domain in the USA.

  12. Urine melanin test

    MedlinePlus

    Thormahlen's test; Melanin - urine ... A clean-catch urine sample is needed. ... this substance that it shows up in the urine. ... Normally, melanin is not present in urine. Normal value ranges may ... measurements or test different samples. Talk to your health ...

  13. Interlaboratory and between-specimen comparisons of diagnostic tests for leptospirosis in sheep and cattle.

    PubMed

    Fang, Fang; Collins-Emerson, Julie M; Heuer, Cord; Hill, Fraser I; Tisdall, David J; Wilson, Peter R; Benschop, Jackie

    2014-11-01

    A study was performed to investigate interlaboratory test agreement between a research and a commercial veterinary diagnostic laboratory on blood and urine samples, and to investigate test agreement between blood, urine, and kidney samples (research laboratory) for leptospirosis diagnosis. Samples were sourced from 399 sheep and 146 beef cattle from a local abattoir. Interlaboratory agreement for real-time quantitative polymerase chain reaction (qPCR) results on urine samples was almost perfect (kappa = 0.90), despite the use of different amplification targets (DNA gyrase subunit B gene vs. 16s ribosomal RNA gene), chemistries (SYTO9 vs. TaqMan probe), and pre-PCR processing. Interlaboratory agreement for microscopic agglutination test (MAT) positivity was almost perfect (kappa = 0.93) for Leptospira borgpetersenii serovar Hardjo subtype Hardjobovis (Hardjobovis) but moderate (kappa = 0.53) for Leptospira interrogans serovar Pomona (Pomona). Among animals that had different titers recorded, higher Hardjobovis and lower Pomona titers were reported by the commercial laboratory than by the research laboratory (P < 0.005). These interlaboratory comparisons can assist researchers and diagnosticians in interpreting the sometimes discrepant test results. Within the research laboratory, the comparison of qPCR results on urine and kidney showed almost perfect agreement (kappa = 0.84), suggesting that the qPCR on these 2 specimens can be used interchangeably. The agreement between MAT positivity and urine and kidney qPCR results was fair (kappa = 0.32 and kappa = 0.33, respectively). However, the prevalence ratio of urine and kidney qPCR positivity in Hardjobovis-seropositive versus Hardjobovis-seronegative sheep indicated that Hardjobovis seropositivity found in sheep may be able to predict shedding or renal carriage. © 2014 The Author(s).

  14. Noninvasive and Painless Urine Glucose Detection by Using Computer-based Polarimeter

    NASA Astrophysics Data System (ADS)

    Sutrisno; Laksono, Y. A.; Hidayat, N.

    2017-05-01

    Diabetes kills millions of people worldwide each year. It challenges us as researchers to give contribution in early diagnosis to ensure a healthy life. As a matter of fact, common glucose testing devices that have been widely used so far are, at least, glucose meter and urine glucose test strip. The glucose meter ordinarily requires blood taken from patient’s finger. The glucose test strip uses patient’s urine but records unspecific urine glucose level, since the strip only provides the glucose level in some particular ranges. Instead of detecting the glucose level in blood and using the non-specific technique, a noninvasive and painless technique that can detect glucose level accurately will provide a more feasible approach for diabetes diagnosis. The noninvasive and painless urine glucose level monitoring by means of computer-based polarimeter is presented in this paper. The instrument consisted of a power source, a sample box, a light sensor, a polarizer, an analyzer, an analog to digital converter (ADC), and a computer. The concentration of urine glucose concentration was evaluated from the curve of the change in detected optical rotation angle and output potential by the computer-based polarimeter. Statistical analyses by means of Gaussian fitting and linear regression were applied to investigate the rotation angle and urine glucose concentration, respectively. From our experiment, the urine glucose level, measured by glucose test strips, of the normal patient was 100 mg/dl, and the diabetic patient was 500 mg/dl. Our polarimeter even read more precise values for the urine glucose concentrations of those normal and diabetic of the same patients, i.e. 50.61 mg/dl and 502.41 mg/dl, respectively. In other words, the results showed that our polarimeter was able to quantitatively measure the urine glucose level more accurate than urine glucose test strips. Hence, this computer-based polarimeter could be used as an alternative for early detection of urine glucose with noninvasive and painless characteristics.

  15. Calcium in Urine Test: MedlinePlus Lab Test Information

    MedlinePlus

    ... medlineplus.gov/labtests/calciuminurinetest.html Calcium in Urine Test To use the sharing features on this page, ... enable JavaScript. What is a Calcium in Urine Test? A calcium in urine test measures the amount ...

  16. No need for a urine culture in elderly hospitalized patients with a negative dipstick test result.

    PubMed

    Shimoni, Zvi; Hermush, Vered; Glick, Joseph; Froom, Paul

    2018-05-18

    To determine the clinical utility/disutility of canceling urine cultures in elderly patients with a negative dipstick. The cohort included consecutive patients aged ≥ 65 years hospitalized in internal medicine departments with an admission urinalysis and urine culture (January 1, 2014 to December 31, 2016). We calculated the sensitivity of the dipstick (either a trace leukocyte esterase or a positive nitrite test result) to detect patients with bacteriuria, and the decrease in urine cultures resulting from cancelation in patients with a negative dipstick. We reviewed the charts of patients with a positive culture but negative dipstick to determine if they received appropriate antibiotic therapy and if the culture results had clinical utility, defined as changes in antibiotic therapy made according to culture results in a patient who did not respond to initial antibiotic therapy. The sensitivity of the dipstick for bacteriuria was 90.8% (95% CI, 89.6-92.0%). Of the 210 patients with a positive culture but negative dipstick, 132 (62.9%) had a diagnosis clearly outside the urinary tract. Thirty-five patients (16.7%) received inappropriate differential antibiotic therapy. Urine cultures did not have clinical utility and canceling urine cultures in those with a negative dipstick would result in a 41.5% (95% CI, 40.3-42.7%) decrease in urine cultures. We conclude that canceling orders for urine cultures in the elderly patient with a negative dipstick did not have clinical disutility and would decrease inappropriate antibiotic therapy. Extrapolation to other settings is dependent on urinalysis methodology, patient selection, and physician ordering and treatment behaviors.

  17. Stability studies of amphetamine and ephedrine derivatives in urine.

    PubMed

    Jiménez, C; de la Torre, R; Ventura, M; Segura, J; Ventura, R

    2006-10-20

    Knowledge of the stability of drugs in biological specimens is a critical consideration for the interpretation of analytical results. Identification of proper storage conditions has been a matter of concern for most toxicology laboratories (both clinical and forensic), and the stability of drugs of abuse has been extensively studied. This concern should be extended to other areas of analytical chemistry like antidoping control. In this work, the stability of ephedrine derivatives (ephedrine, norephedrine, methylephedrine, pseudoephedrine, and norpseudoephedrine), and amphetamine derivatives (amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), and 3,4-methylenedioxymethamphetamine (MDMA)) in urine has been studied. Spiked urine samples were prepared for stability testing. Urine samples were quantified by GC/NPD or GC/MS. The homogeneity of each batch of sample was verified before starting the stability study. The stability of analytes was evaluated in sterilized and non-sterilized urine samples at different storage conditions. For long-term stability testing, analyte concentration in urine stored at 4 degrees C and -20 degrees C was determined at different time intervals for 24 months for sterile urine samples, and for 6 months for non-sterile samples. For short-term stability testing, analyte concentration was evaluated in liquid urine stored at 37 degrees C for 7 days. The effect of repeated freezing (at -20 degrees C) and thawing (at room temperature) was also studied in sterile urine for up to three cycles. No significant loss of the analytes under study was observed at any of the investigated conditions. These results show the feasibility of preparing reference materials containing ephedrine and amphetamine derivatives to be used for quality control purposes.

  18. Temporary Urine and Brine Stowage System (TUBSS) Materials Selection and Testing

    NASA Technical Reports Server (NTRS)

    Carrigan, Caitlin; Dries, Kevin; Pensinger, Stuart

    2011-01-01

    Storing wastewater in the event of a system anomaly is a necessity for closed loop water recovery systems. The temporary urine and brine stowage system (TUBSS) is an assembly used to store and transfer pre-treated urine (PTU) and brine for processing or disposal at a later date. This paper describes the selection and testing of several candidate materials from both a chemical and material strength standpoint. In addition, this paper will provide results of testing as well as lessons learned from the project, culminating in the successful launch of the hardware.

  19. Substitution of human for horse urine disproves an accusation of doping*.

    PubMed

    Díaz, Silvina; Kienast, Mariana E; Villegas-Castagnasso, Egle E; Pena, Natalia L; Manganare, Marcos M; Posik, Diego; Peral-García, Pilar; Giovambattista, Guillermo

    2008-09-01

    In order to detect switching and/or manipulation of samples, the owner of a stallion asked our lab to perform a DNA test on a positive doping urine sample. The objective was to compare the urine DNA profile versus blood and hair DNA profiles from the same stallion. At first, 10 microsatellite markers were investigated to determine the horse identity. No results were obtained when horse specific markers were typed in the urine sample. In order to confirm the species origin of this sample we analyzed the mitochondrial cytochrome b gene. This analysis from blood and hair samples produced reproducible and clear PCR-RFLP patterns and DNA sequence match with those expected for horse, while the urine sample results were coincident with human. These results allowed us to exclude the urine sample from the questioned stallion and determine its human species origin, confirming the manipulation of urine sample.

  20. Coca tea consumption causes positive urine cocaine assay.

    PubMed

    Mazor, Suzan S; Mycyk, Mark B; Wills, Brandon K; Brace, Larry D; Gussow, Leon; Erickson, Timothy

    2006-12-01

    Coca tea, derived from the same plant that is used to synthesize cocaine, is commonly consumed in South America and easily obtained in the United States. To determine whether consumption of coca tea would result in a positive urine toxicology screen for cocaine metabolites. Five healthy adult volunteers consumed coca tea and underwent serial quantitative urine testing for cocaine metabolites by fluorescence polarization immunoassay. The cutoff for a positive assay was chosen at 300 ng/ml, the National Institute on Drug Abuse standard. Each participant's urine cocaine assay was positive (level exceeding 300 ng/ml) by 2 h after ingestion. Three out of five participants' samples remained positive at 36 h. Mean urine benzoylecgonine concentrations in all postconsumption samples was 1777 ng/ml (95% confidence interval: 1060-2495). Coca tea ingestion resulted in a positive urine assay for cocaine metabolite. Healthcare professionals should consider a history of coca tea ingestion when interpreting urine toxicology results.

  1. Advances in the Diagnosis of Human Opisthorchiasis: Development of Opisthorchis viverrini Antigen Detection in Urine

    PubMed Central

    Duenngai, Kunyarat; Wangboon, Chompunoot; Sithithaworn, Jiraporn; Watwiengkam, Nattaya; Namwat, Nisana; Techasen, Anchalee; Loilome, Watcharin; Yongvanit, Puangrat; Loukas, Alex; Sithithaworn, Paiboon; Bethony, Jeffrey M.

    2015-01-01

    Background Many strategies to control opisthorchiasis have been employed in Thailand, but not in the other neighbouring countries. Specific control methods include mass drug administration (MDA) and health education to reduce raw fish consumption. These control efforts have greatly shifted the epidemiology of Opisthorchis viverrini (OV) infection over the last decade from presenting as densely concentrated "heavy" infections in single villages to widespread "light" OV infections distributed over wide geographical areas. Currently, the "gold standard" detection method for OV infection is formalin ethyl-acetate concentration technique (FECT), which has limited diagnostic sensitivity and diagnostic specificity for light OV infections, with OV eggs often confused with eggs of minute intestinal flukes (MIFs) in feces. In this study, we developed and evaluated the diagnostic performance of a monoclonal antibody-based enzyme-linked immunosorbent assay for the measurement of OV excretory-secretory (ES) antigens in urine (urine OV-ES assay) for the diagnosis of opisthorchiasis compared to the gold standard detection FECT method. Methodology We tested several methods for pre-treating urine samples prior to testing the diagnostic performance of the urine OV-ES assay. Using trichloroacetic acid (TCA) pre-treated urine, we compared detection and quantification of OV infection using the urine OV-ES assay versus FECT in OV-endemic areas in Northeastern Thailand. Receiver operating characteristic (ROC) curves were used to determine the diagnostic sensitivity and specificity of the urine OV-ES assay using TCA pre-treated urine, and to establish diagnostic positivity thresholds. The Positive Predictive Value as well as the likelihood of obtaining a positive test result (LR+) or a negative test result (LR-) were calculated for the established diagnostic positivity threshold. Diagnostic risks (Odds Ratios) were estimated using logistic regression. Results When urine samples were pre-treated with TCA prior to use in the urine OV-ES assay, the analytical sensitivity was significantly improved. Using TCA pre-treatment of urine, the urine OV-ES assay had a limit of detection (LoD) of 39 ng/ml compared to the LoD of 52 ng/mL reported for coprological antigen detection methods. Similarly, the urine OV-ES assay correlated significantly with intensity of OV infection as measured by FECT. The urine OV-ES assay was also able to detect 28 individuals as positive from the 63 (44.4%) individuals previously determined to be negative using FECT. The likelihood of a positive diagnosis of OV infection by urine OV-ES assay increased significantly with the intensity of OV infection as determined by FECT. With reference to FECT, the sensitivity and specificity of the urine OV-ES assay was 81% and 70%, respectively. Conclusion The detection of OV-infection by the urine OV-ES assay showed much greater diagnostic sensitivity and diagnostic specificity than the current "gold standard" FECT method for the detection and quantification of OV infection. Due to its ease-of-use, and noninvasive sample collection (urine), the urine OV-ES assay offers the potential to revolutionize the diagnosis of liver fluke infection and provide an effective tool for control and elimination of these tumorigenic parasites. PMID:26485024

  2. Comparison of Four Strong Acids on the Precipitation Potential of Gypsum in Brines During Distillation of Pretreated, Augmented Urine

    NASA Technical Reports Server (NTRS)

    Muirhead, Dean; Carrier, Christopher

    2012-01-01

    In this study, three different mineral acids were substituted for sulfuric acid (H2SO4) in the urine stabilizer solution to eliminate the excess of sulfate ions in pretreated urine and assess the impact on maximum water recovery to avoid precipitation of minerals during distillation. The study evaluated replacing 98% sulfuric acid with 85% phosphoric acid (H3PO4), 37% hydrochloric acid (HCl), or 70% nitric acid (HNO3). The effect of lowering the oxidizer concentration in the pretreatment formulation also was studied. This paper summarizes the test results, defines candidate formulations for further study, and specifies the injection masses required to stabilize urine and minimize the risk of mineral precipitation during distillation. In the first test with a brine ersatz acidified with different acids, the solubility of calcium in gypsum saturated solutions was measured. The solubility of gypsum was doubled in the brines acidified with the alternative acids compared to sulfuric acid. In a second series of tests, the alternative acid pretreatment concentrations were effective at preventing precipitation of gypsum and other minerals up to 85% water recovery from 95th-percentile pretreated, augmented urine. Based on test results, phosphoric acid is recommended as the safest alternative to sulfuric acid. It also is recommended that the injected mass concentration of chromium trioxide solution be reduced by 75% to minimize liquid resupply mass by about 50%, reduce toxicity of brines, and reduce the concentration of organic acids in distillate. The new stabilizer solution formulations and required doses to stabilize urine and prevent precipitation of minerals up to 85% water recovery are given. The formulations in this study were tested on a limited number of artificially augmented urine batches collected from employees at the Johnson Space Center (JSC). This study successfully demonstrated that the desired physical and chemical stability of pretreated urine and brines can be achieved using alternate pretreatment formulations under laboratory conditions. Additional testing and hazard assessments will be required to determine the feasibility of utilizing the proposed urine pretreatment formulations on ISS.

  3. Interlaboratory trial for the measurement of total cobalt in equine urine and plasma by ICP-MS.

    PubMed

    Popot, Marie-Agnes; Ho, Emmie N M; Stojiljkovic, Natali; Bagilet, Florian; Remy, Pierre; Maciejewski, Pascal; Loup, Benoit; Chan, George H M; Hargrave, Sabine; Arthur, Rick M; Russo, Charlie; White, James; Hincks, Pamela; Pearce, Clive; Ganio, George; Zahra, Paul; Batty, David; Jarrett, Mark; Brooks, Lydia; Prescott, Lise-Anne; Bailly-Chouriberry, Ludovic; Bonnaire, Yves; Wan, Terence S M

    2017-09-01

    Cobalt is an essential mineral micronutrient and is regularly present in equine nutritional and feed supplements. Therefore, cobalt is naturally present at low concentrations in biological samples. The administration of cobalt chloride is considered to be blood doping and is thus prohibited. To control the misuse of cobalt, it was mandatory to establish an international threshold for cobalt in plasma and/or in urine. To achieve this goal, an international collaboration, consisting of an interlaboratory comparison between 5 laboratories for the urine study and 8 laboratories for the plasma study, has been undertaken. Quantification of cobalt in the biological samples was performed by inductively coupled plasma-mass spectrometry (ICP-MS). Ring tests were based on the analysis of 5 urine samples supplemented at concentrations ranging from 5 up to 500 ng/mL and 5 plasma samples spiked at concentrations ranging from 0.5 up to 25 ng/mL. The results obtained from the different laboratories were collected, compiled, and compared to assess the reproducibility and robustness of cobalt quantification measurements. The statistical approach for the ring test for total cobalt in urine was based on the determination of percentage deviations from the calculated means, while robust statistics based on the calculated median were applied to the ring test for total cobalt in plasma. The inter-laboratory comparisons in urine and in plasma were successful so that 97.6% of the urine samples and 97.5% of the plasma samples gave satisfactory results. Threshold values for cobalt in plasma and urine were established from data only obtained by laboratories involved in the ring test. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  4. Urinary lithogenesis risk tests: comparison of a commercial kit and a laboratory prototype test.

    PubMed

    Grases, Félix; Costa-Bauzá, Antonia; Prieto, Rafel M; Arrabal, Miguel; De Haro, Tomás; Lancina, Juan A; Barbuzano, Carmen; Colom, Sergi; Riera, Joaquín; Perelló, Joan; Isern, Bernat; Sanchis, Pilar; Conte, Antonio; Barragan, Fernando; Gomila, Isabel

    2011-11-01

    Renal stone formation is a multifactorial process depending in part on urine composition. Other parameters relate to structural or pathological features of the kidney. To date, routine laboratory estimation of urolithiasis risk has been based on determination of urinary composition. This process requires collection of at least two 24 h urine samples, which is tedious for patients. The most important feature of urinary lithogenic risk is the balance between various urinary parameters, although unknown factors may be involved. The objective of this study was to compare data obtained using a commercial kit with those of a laboratory prototype, using a multicentre approach, to validate the utility of these methods in routine clinical practice. A simple new commercial test (NefroPlus®; Sarstedt AG & Co., Nümbrecht, Germany) evaluating the capacity of urine to crystallize calcium salts, and thus permitting detection of patients at risk for stone development, was compared with a prototype test previously described by this group. Urine of 64 volunteers produced during the night was used in these comparisons. The commercial test was also used to evaluate urine samples of 83 subjects in one of three hospitals. Both methods were essentially in complete agreement (98%) with respect to test results. The multicentre data were: sensitivity 94.7%; specificity 76.9%; positive predictive value (lithogenic urine) 90.0%; negative predictive value (non-lithogenic urine) 87.0%; test efficacy 89.2%. The new commercial NefroPlus test offers fast and cheap evaluation of the overall risk of development of urinary calcium-containing calculi.

  5. Evaluation of the BinaxNOW® Streptococcus pneumoniae antigen test on fresh, frozen and concentrated urine samples in elderly patients with and without community-acquired pneumonia.

    PubMed

    Saukkoriipi, Annika; Pascal, Thierry; Palmu, Arto A

    2016-02-01

    We evaluated the BinaxNOW® urine antigen test in elderly. For fresh un-concentrated urine samples, the sensitivity for pneumococcal pneumonia was 63% and specificity 97%. After freezing and concentration, the results comparable to positive control line in intensity at 60 min gave high sensitivity (81%) with no loss in specificity (96%). Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Smartphone-Based Point-of-Care Urinalysis Under Variable Illumination

    PubMed Central

    Ra, Moonsoo; Lim, Chiawei; Han, Sehui; Jung, Chansung; Kim, Whoi-Yul

    2018-01-01

    Urine tests are performed by using an off-the-shelf reference sheet to compare the color of test strips. However, the tabular representation is difficult to use and more prone to visual errors, especially when the reference color-swatches to be compared are spatially apart. Thus, making it is difficult to distinguish between the subtle differences of shades on the reagent pads. This manuscript represents a new arrangement of reference arrays for urine test strips (urinalysis). Reference color swatches are grouped in a doughnut chart, surrounding each reagent pad on the strip. The urine test can be evaluated using naked eye by referring to the strip with no additional sheet necessary. Along with this new strip, an algorithm for smartphone based application is also proposed as an alternative to deliver diagnostic results. The proposed colorimetric detection method evaluates the captured image of the strip, under various color spaces and evaluates ten different tests for urine. Thus, the proposed system can deliver results on the spot using both naked eye and smartphone. The proposed scheme delivered accurate results under various environmental illumination conditions without any calibration requirements, exhibiting performances suitable for real-life applications and an ease for a common user. PMID:29333352

  7. Porphyrins - urine test

    MedlinePlus

    Urine uroporphyrin; Urine coproporphyrin; Porphyria - uroporphyrin ... After you provide a urine sample, it is tested in the lab. This is called a random urine sample. If needed, your health care provider ...

  8. Crystals in Urine Test: MedlinePlus Lab Test Information

    MedlinePlus

    ... medlineplus.gov/labtests/crystalsinurinetest.html Crystals in Urine Test To use the sharing features on this page, ... enable JavaScript. What is a Crystals in Urine Test? Your urine contains many chemicals. Sometimes these chemicals ...

  9. Use of Urine Testing in Outpatients Treated for Urinary Tract Infection

    PubMed Central

    Yiee, Jenny H.; Smith, Alexandria; Hanley, Janet; Saigal, Christopher S.

    2013-01-01

    OBJECTIVE: To characterize urine test use in ambulatory, antibiotic-treated pediatric urinary tract infection (UTI). METHODS: We studied children <18 years who had an outpatient UTI and a temporally associated antibiotic prescription from 2002 through 2007 by using a large claims database, Innovus i3. We evaluated urine-testing trends and performed multivariable logistic regression to assess for factors associated with urine culture use. RESULTS: Of 40 603 treated UTI episodes in 28 678 children, urinalysis was performed in 76%, and urine culture in 57%; 32% of children <2 years had no urinalysis or culture performed for an antibiotic-treated UTI episode. Urine culture use decreased during the study period from 60% to 54% (P < .001). We observed variation in urine culture use with age (<2 years: odds ratio [OR] 1.0, 95% confidence interval [CI] 0.9–1.1; 2–5 years: OR 1.3, 95% CI 1.2–1.4; 6–12 years: OR 1.3, 95% CI 1.2–1.4, compared with 13–17 years); gender (boys: OR 0.8, 95% CI 0.8–0.9); and specialty (pediatrics: OR 2.6, 95% CI 2.5–2.8; emergency medicine, OR 1.2, 95% CI 1.1–1.3; urology: OR 0.5, 95% CI 0.4–0.6, compared with family/internal medicine). Recent antibiotic exposure (OR 1.1, 95% CI 1.1–1.2) and empirical broad-spectrum prescription (OR 1.2, 95% CI 1.1–1.2) were associated with urine culture use, whereas previous UTI and urologic anomalies were not. CONCLUSIONS: Providers often do not obtain urine tests when prescribing antibiotics for outpatient pediatric UTI. Variation in urine culture use was observed based on age, gender, and physician specialty. Additional research is necessary to determine the implications of empirical antibiotic prescription for pediatric UTI without confirmatory urine testing. PMID:23918886

  10. Microbiological test results using three urine pretreatment regimes with 316L stainless steel

    NASA Technical Reports Server (NTRS)

    Huff, Timothy L.

    1993-01-01

    Three urine pretreatments, (1) Oxone (Dupont) and sulfuric acid, (2) sodium hypochlorite and sulfuric acid, (3) and ozone, were studied for their ability to reduce microbial levels in urine and minimize surface attachment to 316L stainless steel coupons. Urine samples inoculated with Bacillus insolitus and a filamentous mold, organisms previously recovered from the vapor compression distillation subsystem of NASA Space Station Freedom water recovery test were tested in glass corrosion cells containing base or weld metal coupons. Microbial levels, changes in pH, color, turbidity, and odor of the fluid were monitored over the course of the 21-day test. Specimen surfaces were examined by scanning electron microscopy at completion of the test for microbial attachment. Ozonated urine samples were less turbid and had lower microbial levels than controls or samples receiving other pretreatments. Base metal coupons receiving pretreatment were relatively free of attached bacteria. However, well-developed biofilms were found in the heat-affected regions of welded coupons receiving Oxone and hypochlorite pretreatments. Few bacteria were observed in the same regions of the ozone pretreatment sample.

  11. Protein urine test

    MedlinePlus

    Urine protein; Albumin - urine; Urine albumin; Proteinuria; Albuminuria ... After you provide a urine sample, it is tested. The health care provider uses a dipstick made with a color-sensitive pad. The color change ...

  12. International Space Station Urine Monitoring System Functional Integration and Science Testing

    NASA Technical Reports Server (NTRS)

    Rodriquez, Branelle R.; Broyan, James Lee, Jr.

    2011-01-01

    Exposure to microgravity during human spaceflight needs to be better understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Measuring the calcium and other metabolic byproducts in a crew member s urine can evaluate the effectiveness of bone loss countermeasures. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross-contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross-contamination (<0.7 mL urine) and has volume accuracy of 2% between 100 to 1000 mL urine voids. Designed to provide a non-invasive means to collect urine samples from crew members, the ISS UMS operates in-line with the Node 3 Waste and Hygiene Compartment (WHC). The ISS UMS has undergone modifications required to interface with the WHC, including material changes, science algorithm improvements, and software platform revisions. Integrated functional testing was performed to determine the pressure drop, air flow rate, and the maximum amount of fluid capable of being discharged from the UMS to the WHC. This paper will detail the results of the science and the functional integration tests.

  13. Diagnostic accuracy of uriSed automated urine microscopic sediment analyzer and dipstick parameters in predicting urine culture test results.

    PubMed

    Huysal, Kağan; Budak, Yasemin U; Karaca, Ayse Ulusoy; Aydos, Murat; Kahvecioğlu, Serdar; Bulut, Mehtap; Polat, Murat

    2013-01-01

    Urinary tract infection (UTI) is one of the most common types of infection. Currently, diagnosis is primarily based on microbiologic culture, which is time- and labor-consuming. The aim of this study was to assess the diagnostic accuracy of urinalysis results from UriSed (77 Electronica, Budapest, Hungary), an automated microscopic image-based sediment analyzer, in predicting positive urine cultures. We examined a total of 384 urine specimens from hospitalized patients and outpatients attending our hospital on the same day for urinalysis, dipstick tests and semi-quantitative urine culture. The urinalysis results were compared with those of conventional semiquantitative urine culture. Of 384 urinary specimens, 68 were positive for bacteriuria by culture, and were thus considered true positives. Comparison of these results with those obtained from the UriSed analyzer indicated that the analyzer had a specificity of 91.1%, a sensitivity of 47.0%, a positive predictive value (PPV) of 53.3% (95% confidence interval (CI) = 40.8-65.3), and a negative predictive value (NPV) of 88.8% (95% CI = 85.0-91.8%). The accuracy was 83.3% when the urine leukocyte parameter was used, 76.8% when bacteriuria analysis of urinary sediment was used, and 85.1% when the bacteriuria and leukocyturia parameters were combined. The presence of nitrite was the best indicator of culture positivity (99.3% specificity) but had a negative likelihood ratio of 0.7, indicating that it was not a reliable clinical test. Although the specificity of the UriSed analyzer was within acceptable limits, the sensitivity value was low. Thus, UriSed urinalysis resuIts do not accurately predict the outcome of culture.

  14. Urine culture guided antibiotic interventions: A pharmacist driven antimicrobial stewardship effort in the ED.

    PubMed

    Zhang, Xi; Rowan, Nicole; Pflugeisen, Bethann Mangel; Alajbegovic, Sanjin

    2017-04-01

    Antibiotics are overprescribed for abnormal urine tests including asymptomatic bacteriuria (AB), contributing to rising antimicrobial resistance rates. Pharmacists reviewed urine cultures daily from emergency department (ED) encounters to assess antibiotic appropriateness. We studied antibiotic prescribing practices and assessed compliance to national guidelines, correlations with urine analysis (UA) components, and opportunities for antimicrobial stewardship in the ED. This quality improvement project (QIP) was a prospective cohort study at a community hospital ED, with data collected from finalized urine cultures resulting October 30, 2014 through January 5, 2015. Analyses were conducted using Chi-squared and Fisher Exact tests and stepwise multiple logistic regression. Urine cultures from 457 encounters were reviewed, of which 136 met the inclusion criteria as non-pregnant and asymptomatic for urinary tract infection (UTI). 43% of 136 patients were treated with antibiotics, for a total of 426 antibiotic days. Pharmacist interventions for these patients resulted in 122/426 (29%) of potential antibiotic days saved. Factors found to significantly increase the odds of antibiotic prescribing in asymptomatic patients included presence of leukocyte esterase (OR=4.5, 95% CI: 1.2-17.2; p=0.03) or nitrites (OR=10.8, 95% CI: 1.7-68.1; p=0.01) in the urine and age≥75 (OR=3.5, 95% CI: 1.2-9.6, p=0.02). Pharmacist intervention in discontinuing or modifying antibiotics for asymptomatic patients with urine cultures reduced unnecessary antibiotic exposure and was a first step in antimicrobial stewardship efforts in the ED. Future work includes limiting urine tests and subsequent antibiotic therapy for non-pregnant asymptomatic patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Monitoring hydration status pre- and post-training among university athletes using urine color and weight loss indicators.

    PubMed

    Webb, Marquitta C; Salandy, Sinead T; Beckford, Safiya E

    2016-01-01

    To investigate the hydration status pre- and post-training among university athletes using urine color and weight loss as indicators. Participants were 52 university athletes training for campus games in a developing country. Pre- and post-training urine specimens were compared with a standard urine color scale. Paired t tests were used to compare urine color and difference in body mass pre- and post-training. The mean age of the athletes was 22.87 ± 3.21. A statistically significance difference (p < .01) was observed between pre- (4.31 ± 1.75) and post- (5.67 ± 1.45) training urine color values for males. Hydration status and weight post-training were statistically significantly different both at the level of p < .01. The results suggest that there is a link between urine color and body mass difference among the student athletes tested. Exercise increases hypohydration due to fluid losses, and therefore attention should be given to fluid supplementation and individualization of fluid intake for each athlete.

  16. The use of semi-quantitative tests at Cesarean section delivery for the differentiation of canine fetal fluids from maternal urine on the basis of biochemical characteristics.

    PubMed

    Balogh, Orsolya; Roch, Marie; Keller, Stefanie; Michel, Erika; Reichler, Iris M

    2017-01-15

    In dogs, there is no diagnostic test to identify and differentiate fetal fluids from maternal urine in the event that a clear-yellowish vulvar discharge is observed pre-whelping. The objective of this study was to find a test that could easily and accurately identify rupture of the fetal membranes preceding parturition. Maternal urine, and amniotic fluid (AMF) and allantoic fluid (ALF) from only one fetus per bitch, were collected intraoperatively during Cesarean section. Specific gravity (SG) was analyzed with a refractometer, whereas the presence of leukocytes, protein, glucose, ketones, bilirubin, urobilinogen, nitrite, erythrocyte/hemoglobin (Hb), and the pH were assessed using a urine dipstick (Combur-Test ® ). Combined calcium and magnesium (Ca/Mg) content were evaluated with the Total Hardness Test. The AmniSure test, which detects rupture of fetal membranes in women on the basis of the presence of human placental alpha microglobulin-1, was also performed on canine AMF, ALF, and urine. Data were analyzed using the Fisher's exact test, Wilcoxon signed-rank test, and Pearson's correlation. Sensitivity, specificity, and positive and negative likelihood ratios (LR) were calculated for parameters with significant difference between urine and both fetal fluids. Maternal urine had higher SG and lower leukocyte, protein, Hb, and Ca/Mg content than AMF and ALF. Glucose was more often present in AMF (n = 17) and ALF (n = 12) than in urine (n = 1), whereas ketone bodies were rarely detected in ALF compared with urine. Bilirubin content was higher in urine and ALF than in AMF. AMF pH was less variable and higher than the pH of ALF or urine. The AmniSure was negative in all samples tested. Sensitivity and specificity for SG and for the detection of leukocytes, protein, glucose, Hb, Ca/Mg, and glucose without ketones in urine and fetal fluids were between 42% to 100% and 65% to 100%, respectively. Best positive LR was achieved for the detection of glucose without ketones and best negative LR for SG of 1.022 or less. In conclusion, the AmniSure test, which is used in humans with high diagnostic accuracy, cannot identify AMF and ALF in dogs. On the basis of our results in 26 dogs undergoing Cesarean section, the presence or absence of fetal fluids could be best determined by a positive glucose test without ketone bodies or by SG higher than 1.022, respectively. These tests may serve as additional tools to recognize parturition if clear-yellowish vulvar discharge is present in a term pregnant bitch, but their accuracy and practicability in the clinical setting need to be confirmed. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Evaluation of the automated urine particle analyzer UF-1000i screening for urinary tract infection in nonpregnant women.

    PubMed

    Dai, Qingkai; Jiang, Yongmei; Shi, Hua; Zhou, Wei; Zhou, Shengjie; Yang, Hui

    2014-01-01

    Urinary tract infection (UTI) is a widespread disease in women. Urine culture is still the "gold standard" diagnostic test for UTI, but most of them are negative. To reduce unnecessary culture, we evaluated the automated urine particle analyzer UF-1000i screening for UTI in nonpregnant women. The urine specimens submitted to our laboratory were submitted for culture and tested by the Sysmex UF-1000i. Bacteria and white blood cell (WBC) counts were compared to standard urine culture results to assess the best cutoff values. In this study, 272 urine samples were included, of which 98 (36.0%) were culture positive with a bacterial cutoff value of 10 x 10(5) CFU/mL. A combination of bacterial (> 95/microL) and/or WBC count (> 24/microL) provided the best screening for UTI, with a sensitivity of 0.99 and a specificity of 0.82 compared with the urine culture. Sysmex UF-1000i could be used as a screening test for UTI in nonpregnant women. According to the distribution and range of the bacterial scattergram, we could primarily identify and differentiate between Gram-negative and Gram-positive bacteria.

  18. Urine Culture Testing in Community Nursing Homes: Gateway to Antibiotic Overprescribing.

    PubMed

    Sloane, Philip D; Kistler, Christine E; Reed, David; Weber, David J; Ward, Kimberly; Zimmerman, Sheryl

    2017-05-01

    OBJECTIVE To describe current practice around urine testing and identify factors leading to overtreatment of asymptomatic bacteriuria in community nursing homes (NHs) DESIGN Observational study of a stratified random sample of NH patients who had urine cultures ordered in NHs within a 1-month study period SETTING 31 NHs in North Carolina PARTICIPANTS 254 NH residents who had a urine culture ordered within the 1-month study period METHODS We conducted an NH record audit of clinical and laboratory information during the 2 days before and 7 days after a urine culture was ordered. We compared these results with the urine antibiogram from the 31 NHs. RESULTS Empirical treatment was started in 30% of cases. When cultures were reported, previously untreated cases received antibiotics 89% of the time for colony counts of ≥100,000 CFU/mL and in 35% of cases with colony counts of 10,000-99,000 CFU/mL. Due to the high rate of prescribing when culture results returned, 74% of these patients ultimately received a full course of antibiotics. Treated and untreated patients did not significantly differ in temperature, frequency of urinary signs and symptoms, or presence of Loeb criteria for antibiotic initiation. Factors most commonly associated with urine culture ordering were acute mental status changes (32%); change in the urine color, odor, or sediment (17%); and dysuria (15%). CONCLUSIONS Urine cultures play a significant role in antibiotic overprescribing. Antibiotic stewardship efforts in NHs should include reduction in culture ordering for factors not associated with infection-related morbidity as well as more scrutiny of patient condition when results become available. Infect Control Hosp Epidemiol 2017;38:524-531.

  19. Urine Culture on Admission Impacts Antibiotic Use and Length of Stay: A Retrospective Cohort Study.

    PubMed

    Horstman, Molly J; Spiegelman, Andrew M; Naik, Aanand D; Trautner, Barbara W

    2018-05-01

    OBJECTIVETo examine the impact of urine culture testing on day 1 of admission on inpatient antibiotic use and hospital length of stay (LOS).DESIGNWe performed a retrospective cohort study using a national dataset from 2009 to 2014.SETTINGThe study used data from 230 hospitals in the United States.PARTICIPANTSAdmissions for adults 18 years and older were included in this study. Hospitalizations were matched with coarsened exact matching by facility, patient age, gender, Medicare severity-diagnosis related group (MS-DRG), and 3 measures of disease severity.METHODSA multilevel Poisson model and a multilevel linear regression model were used to determine the impact of an admission urine culture on inpatient antibiotic use and LOS.RESULTSMatching produced a cohort of 88,481 patients (n=41,070 with a culture on day 1, n=47,411 without a culture). A urine culture on admission led to an increase in days of inpatient antibiotic use (incidence rate ratio, 1.26; P<.001) and resulted in an additional 36,607 days of inpatient antibiotic treatment. Urine culture on admission resulted in a 2.1% increase in LOS (P=.004). The predicted difference in bed days of care between admissions with and without a urine culture resulted in 6,071 additional bed days of care. The impact of urine culture testing varied by admitting diagnosis.CONCLUSIONSPatients with a urine culture sent on day 1 of hospital admission receive more days of antibiotics and have a longer hospital stay than patients who do not have a urine culture. Targeted interventions may reduce the potential harms associated with low-yield urine cultures on day 1.Infect Control Hosp Epidemiol 2018;39:547-554.

  20. [Is bacteriological testing of bladder urine informative in acute obstructive pyelo- nephritis?

    PubMed

    Kogan, M I; Naboka, Yu L; Bedzhanyan, S K; Mitusova, E V; Gudima, I A; Morgun, P P; Vasileva, L I

    2017-07-01

    The problem of the etiology and pathogenesis of acute obstructive pyelonephritis (OOP) remains one of the challenging issues of modern urology. Etiological agents of pyelonephritis can be both gram-negative and gram-positive opportunistic bacteria mostly belonging to the normal flora in humans. The generally accepted diagnostic work-up involves a bacteriological testing of not pelvic urine, but of bladder urine collected by a transurethral catheter or midstream specimens of urine collected from the patients. The aim of our study was to compare the microbiota of bladder and pelvic urine in patients with OOP. The study comprised 72 sequentially selected patients (12 men and 60 women) with OOP associated with ureteral stones. Mean age of patients was 53.7+/-0.5 years. All patients underwent bacteriological examination of the bladder urine collected by a transurethral catheter and pelvic urine obtained after relieving stone-related ureteral obstruction. Urinary diversion was performed using j-j stent and PCN in 64 and 8 patients, respectively. Preoperative prophylactic antibiotics were administered routinely. Bacteriological testing of urine was carried out using an extended set (9-10) of culture media. Empirical antibiotic therapy was initiated only after the restoration of urine outflow from the kidney and continued for 5-6 days until the availability of bacteriological testing results. Levels of bacteriuria with Enterobacteria, gram-positive pathogens and NAB in two urine samples did not differ significantly (p>0.05). There was a wide range of bacteriuria from 101 to 106 CFU/ml of most microorganisms except @Proteus spp., S. aureus. In bladder urine, the rates of bacteriuria of more or equal 104 CFU/ml for E. coli, Klebsiella spp. and Proteus spp. were 90.9%, 72.7% and 100.0%, respectively. For the remaining microorganisms, predominant bacteriuria was less or equal 103 CFU/ml. In pelvic urine, the rates of bacteriuria of more or equal 104 CFU/ml for E. coli, Klebsiella spp. and Proteus spp. was 71.8%, 40.0% and 66.7%, respectively. Other uropathogens in the pelvic urine mainly had a bacterial count of less or equal 103 CFU/ml. Only the concentration of Corynebacterium spp. in the pelvic urine significantly (p=0.023) differed from that of the bladder urine. There were no significant differences between microbiota of bladder and pelvic urine depending on duration of OOP except higher rates of Corynebacterium spp. in the bladder urine.

  1. 49 CFR 40.41 - Where does a urine collection for a DOT drug test take place?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 1 2014-10-01 2014-10-01 false Where does a urine collection for a DOT drug test... in DOT Urine Collections § 40.41 Where does a urine collection for a DOT drug test take place? (a) A urine collection for a DOT drug test must take place in a collection site meeting the requirements of...

  2. 49 CFR 40.41 - Where does a urine collection for a DOT drug test take place?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 1 2013-10-01 2013-10-01 false Where does a urine collection for a DOT drug test... in DOT Urine Collections § 40.41 Where does a urine collection for a DOT drug test take place? (a) A urine collection for a DOT drug test must take place in a collection site meeting the requirements of...

  3. 49 CFR 40.41 - Where does a urine collection for a DOT drug test take place?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 1 2012-10-01 2012-10-01 false Where does a urine collection for a DOT drug test... in DOT Urine Collections § 40.41 Where does a urine collection for a DOT drug test take place? (a) A urine collection for a DOT drug test must take place in a collection site meeting the requirements of...

  4. 49 CFR 40.41 - Where does a urine collection for a DOT drug test take place?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 1 2011-10-01 2011-10-01 false Where does a urine collection for a DOT drug test... in DOT Urine Collections § 40.41 Where does a urine collection for a DOT drug test take place? (a) A urine collection for a DOT drug test must take place in a collection site meeting the requirements of...

  5. Power of Orbitrap-based LC-high resolution-MS/MS for comprehensive drug testing in urine with or without conjugate cleavage or using dried urine spots after on-spot cleavage in comparison to established LC-MSn or GC-MS procedures.

    PubMed

    Michely, Julian A; Meyer, Markus R; Maurer, Hans H

    2018-01-01

    Reliable, sensitive, and comprehensive urine screening procedures by gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-mass spectrometry (LC-MS) with low or high resolution (HR) are of high importance for drug testing, adherence monitoring, or detection of toxic compounds. Besides conventional urine sampling, dried urine spots are of increasing interest. In the present study, the power of LC-HR-MS/MS was investigated for comprehensive drug testing in urine with or without conjugate cleavage or using dried urine spots after on-spot cleavage in comparison to established LC-MS n or GC-MS procedures. Authentic human urine samples (n = 103) were split in 4 parts. One aliquot was prepared by precipitation (UP), one by UP with conjugate cleavage (UglucP), one spot on filter paper cards and prepared by on-spot cleavage followed by liquid extraction (DUSglucE), and one worked-up by acid hydrolysis, liquid-liquid extraction, and acetylation for GC-MS analysis. The 3 series of LC-HR-MS/MS results were compared among themselves, to corresponding published LC-MS n data, and to screening results obtained by conventional GC-MS. The reference libraries used for the 3 techniques contained over 4500 spectra of parent compounds and their metabolites. The number of all detected hits (770 drug intakes) was set to 100%. The LC-HR-MS/MS approach detected 80% of the hits after UP, 89% after UglucP, and 77% after DUSglucE, which meant over one-third more hits in comparison to the corresponding published LC-MS n results with ≤49% detected hits. The GC-MS approach identified 56% of all detected hits. In conclusion, LC-HR-MS/MS provided the best screening results after conjugate cleavage and precipitation. Copyright © 2017 John Wiley & Sons, Ltd.

  6. Diagnostic yield of hair and urine toxicology testing in potential child abuse cases.

    PubMed

    Stauffer, Stephanie L; Wood, Stephanie M; Krasowski, Matthew D

    2015-07-01

    Detection of drugs in a child may be the first objective finding that can be reported in cases of suspected child abuse. Hair and urine toxicology testing, when performed as part of the initial clinical evaluation for suspected child abuse or maltreatment, may serve to facilitate the identification of at-risk children. Furthermore, significant environmental exposure to a drug (considered by law to constitute child abuse in some states) may be identified by toxicology testing of unwashed hair specimens. In order to determine the clinical utility of hair and urine toxicology testing in this population we performed a retrospective chart review on all children for whom hair toxicology testing was ordered at our academic medical center between January 2004 and April 2014. The medical records of 616 children aged 0-17.5 years were reviewed for injury history, previous medication and illicit drug use by caregiver(s), urine drug screen result (if performed), hair toxicology result, medication list, and outcome of any child abuse evaluation. Hair toxicology testing was positive for at least one compound in 106 cases (17.2%), with unexplained drugs in 82 cases (13.3%). Of these, there were 48 cases in which multiple compounds (including combination of parent drugs and/or metabolites within the same drug class) were identified in the sample of one patient. The compounds most frequently identified in the hair of our study population included cocaine, benzoylecgonine, native (unmetabolized) tetrahydrocannabinol, and methamphetamine. There were 68 instances in which a parent drug was identified in the hair without any of its potential metabolites, suggesting environmental exposure. Among the 82 cases in which hair toxicology testing was positive for unexplained drugs, a change in clinical outcome was noted in 71 cases (86.5%). Urine drug screens (UDS) were performed in 457 of the 616 reviewed cases. Of these, over 95% of positive UDS results could be explained by iatrogenic drug administration. There were no cases in which a urine drug screen alone altered the outcome of a case. In summary, hair toxicology testing proved clinically useful in the evaluation of a child for suspected abuse; in contrast, urine drug testing showed low clinical yield. Copyright © 2015 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  7. Evaluation of hematological and biochemical parameters of pesticide retailers following occupational exposure to a mixture of pesticides.

    PubMed

    Neghab, Masoud; Jalilian, Hamed; Taheri, Shekoufeh; Tatar, Mohsen; Haji Zadeh, Zeynab

    2018-06-01

    This study was undertaken to ascertain whether light occupational exposure to pesticides by retailers might be associated with any liver, kidney, nervous system dysfunction or hematological abnormalities. In this cross-sectional study, 70 male pesticide retailers (cases) and 64 male subjects, randomly selected from the constructions workers of city council contractors, as the referent group, were investigated. Urine and blood samples were taken from all subjects for urine analysis, hematological and biochemical parameters. Data analysis was conducted through SPSS v.19 using t-test and chi-square test. The results of urine analysis showed that the frequency of abnormal urine tests was significantly higher in cases than in referent individuals. Similarly, the results of CBC showed that the mean values of monocyte, hemoglobin, hematocrit, mean corpuscular volume, mean corpuscular hemoglobin and platelet distribution width were significantly lower, and mean corpuscular hemoglobin concentration and red blood cell distribution width were significantly higher in retailers. No significant differences were found for other parameters. These findings indicate that an association exists between exposure to pesticides by retailers and early subtle and sub-clinical changes in the urine tests and hematological parameters. Engineering measures are recommended to eliminate exposure to pesticides and to prevent its associated outcomes. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Interpretation of urine drug testing results in patients using transdermal buprenorphine preparations for the treatment of chronic noncancer pain.

    PubMed

    Markman, John D; Barbosa, William A; Gewandter, Jennifer S; Frazer, Maria; Rast, Shirley; Dugan, Michelle; Nandigam, Kiran; Villareal, Armando; Kwong, Tai C

    2015-06-01

    To determine whether the prevailing liquid chromatography and tandem mass spectroscopy assay (LC-MS/MS) assay designed to monitor buprenorphine compliance of the sublingual formulation used in the substance abuse treatment setting can be extrapolated to the transdermal formulation used in the chronic pain treatment setting, which is 1000-fold less concentrated. Retrospective chart review. Self-reported compliant patients using the transdermal or sublingual formulations of buprenorhphine. Transdermal patch application was also visually confirmed during clinic visits. Urine drug test results from a LC-MS/MS were compared between samples from transdermal and sublingual patients. While all sublingual patients tested positive for at least one metabolite of buprenorphine, only 69% of the transdermal patients did so. In addition, the most abundant metabolite in the transdermal patients was buprenorphine-glucuronide, as compared with norbuprenorphine-glucuronide in sublingual patients. These data suggest that currently available urine drug tests for buprenorphine, including the more expensive LC-MS/MS based assays, may not be sufficiently sensitive to detect the metabolites from transdermal buprenorphine patients. This study highlights the need to evaluate the value and sensitivity of urine drug tests given the wide range of buprenorphine dosing in clinical practice. These results underscore the need for additional cost benefit analyses comparing different confirmatory drug testing techniques including many commercially available drug testing options. © 2014 Wiley Periodicals, Inc. Wiley Periodicals, Inc.

  9. Monitoring cocaine use in substance-abuse-treatment patients by sweat and urine testing.

    PubMed

    Preston, K L; Huestis, M A; Wong, C J; Umbricht, A; Goldberger, B A; Cone, E J

    1999-09-01

    Sweat and urine specimens were collected from 44 methadone-maintenance patients to evaluate the use of sweat testing to monitor cocaine use. Paired sweat patches that were applied and removed weekly (on Tuesdays) were compared with 3-5 consecutive urine specimens collected Mondays, Wednesdays, and Fridays. All patches (N = 930) were extracted in 2.5 mL of solvent and analyzed by ELISA immunoassay (cutoff concentration 10 ng/mL); a subset of patches (N = 591) was also analyzed by gas chromatography-mass spectrometry (GC-MS) for cocaine, benzoylecgonine (BZE), and ecgonine methyl ester (EME) (cutoff concentration 5 ng/mL). Urine specimens were subjected to qualitative analysis by EMIT (cutoff 300 ng/mL) and subsets were analyzed by TDx (semiquantitative, LOD 30 ng/mL) and by GC-MS for cocaine (LOD 5 ng/mL). Results were evaluated to (1) determine the relative amounts of cocaine and its metabolites in sweat; (2) assess replicability in duplicate patches; (3) compare ELISA and GC-MS results for cocaine in sweat; and (4) compare the detection of cocaine use by sweat and urine testing. Cocaine was detected by GC-MS in 99% of ELISA-positive sweat patches; median concentrations of cocaine, BZE, and EME were 378, 78.7, and 74 ng/mL, respectively. Agreement in duplicate patches was approximately 90% by ELISA analysis. The sensitivity, specificity, and efficiency of sweat ELISA cocaine results as compared with sweat GC-MS results were 93.6%, 91.3%, and 93.2%, respectively. The sensitivity, specificity, and efficiency between ELISA sweat patch and EMIT urine results were 97.6%, 60.5%, and 77.7%, respectively. These results support the use of sweat patches for monitoring cocaine use, though further evaluation is needed.

  10. Improving the Diagnosis and Treatment of Urinary Tract Infection in Young Children in Primary Care: Results from the DUTY Prospective Diagnostic Cohort Study

    PubMed Central

    Hay, Alastair D.; Sterne, Jonathan A. C.; Hood, Kerenza; Little, Paul; Delaney, Brendan; Hollingworth, William; Wootton, Mandy; Howe, Robin; MacGowan, Alasdair; Lawton, Michael; Busby, John; Pickles, Timothy; Birnie, Kate; O’Brien, Kathryn; Waldron, Cherry-Ann; Dudley, Jan; Van Der Voort, Judith; Downing, Harriet; Thomas-Jones, Emma; Harman, Kim; Lisles, Catherine; Rumsby, Kate; Durbaba, Stevo; Whiting, Penny; Butler, Christopher C.

    2016-01-01

    PURPOSE Up to 50% of urinary tract infections (UTIs) in young children are missed in primary care. Urine culture is essential for diagnosis, but urine collection is often difficult. Our aim was to derive and internally validate a 2-step clinical rule using (1) symptoms and signs to select children for urine collection; and (2) symptoms, signs, and dipstick testing to guide antibiotic treatment. METHODS We recruited acutely unwell children aged under 5 years from 233 primary care sites across England and Wales. Index tests were parent-reported symptoms, clinician-reported signs, urine dipstick results, and clinician opinion of UTI likelihood (clinical diagnosis before dipstick and culture). The reference standard was microbiologically confirmed UTI cultured from a clean-catch urine sample. We calculated sensitivity, specificity, and area under the receiver operator characteristic (AUROC) curve of coefficient-based (graded severity) and points-based (dichotomized) symptom/sign logistic regression models, and we then internally validated the AUROC using bootstrapping. RESULTS Three thousand thirty-six children provided urine samples, and culture results were available for 2,740 (90%). Of these results, 60 (2.2%) were positive: the clinical diagnosis was 46.6% sensitive, with an AUROC of 0.77. Previous UTI, increasing pain/crying on passing urine, increasingly smelly urine, absence of severe cough, increasing clinician impression of severe illness, abdominal tenderness on examination, and normal findings on ear examination were associated with UTI. The validated coefficient- and points-based model AUROCs were 0.87 and 0.86, respectively, increasing to 0.90 and 0.90, respectively, by adding dipstick nitrites, leukocytes, and blood. CONCLUSIONS A clinical rule based on symptoms and signs is superior to clinician diagnosis and performs well for identifying young children for noninvasive urine sampling. Dipstick results add further diagnostic value for empiric antibiotic treatment. PMID:27401420

  11. Detection of drugs in the urine of body-packers.

    PubMed

    Gherardi, R K; Baud, F J; Leporc, P; Marc, B; Dupeyron, J P; Diamant-Berger, O

    1988-05-14

    The presence of opiates and benzoylecgonine, the major metabolite of cocaine, in the urine was detected by means of enzyme immunoassay in a series of 120 smugglers who had either ingested or inserted into their rectum cocaine or heroin packaged for transportation. There was a striking relation between the presence of drugs in the urine and swallowing of drug-filled bundles (cocaine 49 of 50 cases, heroin 9 of 10). The proportion of positive results was also high in cases of rectal insertion (cocaine 2 of 2, heroin 35 of 58). In 30 cases of cocaine-packet ingestion, serial measurements showed that the accuracy of the test progressively decreased with respect to the detection of residual packets in the body. Drug detection in the urine of suspected body-packers seems to be a useful test, positive results justifying subsequent radiological investigations.

  12. Comparison of urine specimen collection times and testing fractions for the detection of high-risk human papillomavirus and high-grade cervical precancer.

    PubMed

    Senkomago, V; Des Marais, A C; Rahangdale, L; Vibat, C R T; Erlander, M G; Smith, J S

    2016-01-01

    Urine testing for high-risk human papillomavirus (HR-HPV) detection could provide a non-invasive, simple method for cervical cancer screening. We examined whether HR-HPV detection is affected by urine collection time, portion of urine stream, or urine fraction tested, and assessed the performance of HR-HPV testing in urine for detection of cervical intraepithelial neoplasia grade II or worse (CIN2+). A total of 37 female colposcopy clinic attendees, ≥ 30 years, provided three urine samples: "first void" urine collected at home, and "initial stream" and "mid-stream" urine samples collected at the clinic later in the day. Self- and physician-collected brush specimens were obtained at the same clinic visit. Colposcopy was performed and directed biopsies obtained if clinically indicated. For each urine sample, HR-HPV DNA testing was conducted for unfractionated, pellet, and supernatant fractions using the Trovagene test. HR-HPV mRNA testing was performed on brush specimens using the Aptima HPV assay. HR-HPV prevalence was similar in unfractionated and pellet fractions of all urine samples. For supernatant urine fractions, HR-HPV prevalence appeared lower in mid-stream urine (56.8%[40.8-72.7%]) than in initial stream urine (75.7%[61.9-89.5%]). Sensitivity of CIN2+ detection was identical for initial stream urine and physician-collected cervical specimen (89.9%[95%CI=62.7-99.6%]), and similar to self-collected vaginal specimen (79.1%[48.1-96.6%]). This is among the first studies to compare methodologies for collection and processing of urine for HR-HPV detection. HR-HPV prevalence was similar in first void and initial stream urine, and was highly sensitive for CIN2+ detection. Additional research in a larger and general screening population is needed. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. A comparison between on-site immunoassay drug-testing devices and laboratory results.

    PubMed

    Grönholm, M; Lillsunde, P

    2001-09-15

    The aim with this study was to evaluate the accuracy of several on-site testing devices on the market. A part of this study is included in the European Union's (EU's) roadside testing assessment project (ROSITA). An other request for this kind of study came from the Finnish prison department in the Ministry of Justice. The evaluation was performed on both urine assays and oral fluid assays. The on-site test results were compared with laboratory results (gas chromatography-mass spectrometry (GC/MS)). The samples were tested on amphetamines (AMP), cannabinoids (THC), opiates (OPI) and cocaine metabolites (COC). Some of the tests also included a metamphetamine (MET) and a benzodiazepine (BZO) test. Both positive and negative samples were tested. A total of 800 persons and eight on-site devices for urine and two for oral fluid testing were included in this study. Good results were obtained for the urine on-site devices, with accuracies of 93-99% for amphetamines, 97-99% for cannabinoids, 94-98% for opiates and 90-98% for benzodiazepines. However, differences in the ease of performance and interpretation of test result were observed. It was possible to detect amphetamines and opiates in oral fluid by the used on-site devices, but the benzodiazepines and cannabinoids did not fulfil the needs of sensitivity.

  14. [The incidence and risk factors of male urinary tract infection following invasive urodynamic investigation].

    PubMed

    Huang, Zhongming; Li, Hanzhong; Ji, Zhigang; Xiao, He

    2015-11-10

    To assess the prevalence of male urinary tract infection (UTI) after invasive urodynamic studies and to determinate the risk factors by evaluating the clinical characteristics and urodynamic parameters of patients. Six hundred and seventy-one consecutive men were recruited. All patients accepted urine routine tests and(or)urine culture three times. The first culture and routine tests were carried out in the 2 to 4 weeks before urodynamic studies by using clean-catch midstream urine (MSU) or catheter urine specimen. The second urine routine test was carried out at the start of examinations and the last urine culture were carried out in 48-72 hours after the investigations. Male patients with negative results (leucocytes <15 cells/ul and <10(5) colony-forming units per milliliter [cfu/ml]) in 1(st) and 2(nd) time received a standard urodynamic investigation. The investigations of the remaining patients were postponed until the urinary tract infection had been treated. The prevalence of urinary tract infection before urodynamic investigation (with positive results in 1(st) and 2(nd) urine test) was 7.3%, and the prevalence after the investigation in patients without UTI before examination was 10.3%. Bladder outlet obstruction (BOO), age ≥ 65 years, and diabetes were the risk factors for UTI after urodynamic investigation. The most common uropathogens in the urinary tract infections after the urodynamic investigation were Escherichia coli (53.1%, 34/64) and Enterococcus faecalis (17.2%, 11/64). Despite a stringent standard operation protocol, the prevalence of UTI in male patients caused by urodynamic examination is about 10%. For the high-risk patients with BOO, older age, and diabetes, prophylactic antibiotic treatment before or after procedure may be necessary.

  15. A hybrid approach to urine drug testing using high-resolution mass spectrometry and select immunoassays.

    PubMed

    McMillin, Gwendolyn A; Marin, Stephanie J; Johnson-Davis, Kamisha L; Lawlor, Bryan G; Strathmann, Frederick G

    2015-02-01

    The major objective of this research was to propose a simplified approach for the evaluation of medication adherence in chronic pain management patients, using liquid chromatography time-of-flight (TOF) mass spectrometry, performed in parallel with select homogeneous enzyme immunoassays (HEIAs). We called it a "hybrid" approach to urine drug testing. The hybrid approach was defined based on anticipated positivity rates, availability of commercial reagents for HEIAs, and assay performance, particularly analytical sensitivity and specificity for drug(s) of interest. Subsequent to implementation of the hybrid approach, time to result was compared with that observed with other urine drug testing approaches. Opioids, benzodiazepines, zolpidem, amphetamine-like stimulants, and methylphenidate metabolite were detected by TOF mass spectrometry to maximize specificity and sensitivity of these 37 drug analytes. Barbiturates, cannabinoid metabolite, carisoprodol, cocaine metabolite, ethyl glucuronide, methadone, phencyclidine, propoxyphene, and tramadol were detected by HEIAs that performed adequately and/or for which positivity rates were very low. Time to result was significantly reduced compared with the traditional approach. The hybrid approach to urine drug testing provides a simplified and analytically specific testing process that minimizes the need for secondary confirmation. Copyright© by the American Society for Clinical Pathology.

  16. 49 CFR 40.193 - What happens when an employee does not provide a sufficient amount of urine for a drug test?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... sufficient amount of urine for a drug test? 40.193 Section 40.193 Transportation Office of the Secretary of... § 40.193 What happens when an employee does not provide a sufficient amount of urine for a drug test... sufficient amount of urine to permit a drug test (i.e., 45 mL of urine). (b) As the collector, you must do...

  17. 49 CFR 40.193 - What happens when an employee does not provide a sufficient amount of urine for a drug test?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... sufficient amount of urine for a drug test? 40.193 Section 40.193 Transportation Office of the Secretary of... § 40.193 What happens when an employee does not provide a sufficient amount of urine for a drug test... sufficient amount of urine to permit a drug test (i.e., 45 mL of urine). (b) As the collector, you must do...

  18. 49 CFR 40.193 - What happens when an employee does not provide a sufficient amount of urine for a drug test?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... sufficient amount of urine for a drug test? 40.193 Section 40.193 Transportation Office of the Secretary of... § 40.193 What happens when an employee does not provide a sufficient amount of urine for a drug test... sufficient amount of urine to permit a drug test (i.e., 45 mL of urine). (b) As the collector, you must do...

  19. 49 CFR 40.193 - What happens when an employee does not provide a sufficient amount of urine for a drug test?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... sufficient amount of urine for a drug test? 40.193 Section 40.193 Transportation Office of the Secretary of... § 40.193 What happens when an employee does not provide a sufficient amount of urine for a drug test... sufficient amount of urine to permit a drug test (i.e., 45 mL of urine). (b) As the collector, you must do...

  20. A trend analysis of laboratory positive propoxyphene workplace urine drug screens before and after the product recall.

    PubMed

    Price, James

    2015-01-01

    Propoxyphene was withdrawn from the US market in November 2010. This drug is still tested for in the workplace as part of expanded panel nonregulated testing. A convenience sample of urine specimens (n = 7838) were provided by workers from various industries. The percentage of positive specimens with 95% confidence intervals was calculated for each year of the study. Logistic regression was used to assess the impact of the year upon the propoxyphene result. The prevalence of positive propoxyphene tests was much higher before the product's withdrawal from the market. Logistic regression provided evidence of a decreasing linear trend (P < 0.000; β = -0.71). The odds ratio signifies that for every additional year the urine specimens were 0.49 times less likely to be positive for propoxyphene. This favors the determination that the change in propoxyphene positive drug test over the years is not by chance. The conclusion supports no longer performing nonregulated workplace propoxyphene urine drug testing for this population.

  1. Diagnostic value and cost utility analysis for urine Gram stain and urine microscopic examination as screening tests for urinary tract infection.

    PubMed

    Wiwanitkit, Viroj; Udomsantisuk, Nibhond; Boonchalermvichian, Chaiyaporn

    2005-06-01

    The aim of this study was to evaluate the diagnostic properties of urine Gram stain and urine microscopic examination for screening for urinary tract infection (UTI), and to perform an additional cost utility analysis. This descriptive study was performed on 95 urine samples sent for urine culture to the Department of Microbiology, Faculty of Medicine, Chulalongkorn University. The first part of the study was to determine the diagnostic properties of two screening tests (urine Gram stain and urine microscopic examination). Urine culture was set as the gold standard and the results from both methods were compared to this. The second part of this study was to perform a cost utility analysis. The sensitivity of urine Gram stain was 96.2%, the specificity 93.0%, the positive predictive value 94.3% and the negative predictive value 95.2%. False positives occurred with a frequency of 7.0% and false negatives 3.8%. For the microscopic examination, the sensitivity was 65.4%, specificity 74.4%, positive predictive value 75.6% and negative predictive value 64.0%. False positives occurred with a frequency of 25.6% and false negatives 34.6%. Combining urine Gram stain and urine microscopic examination, the sensitivity was 98.1%, specificity 74.4%, positive predictive value 82.3% and negative predictive value 97.0%. False positives occurred with a frequency of 25.6% and false negatives 1.9%. However, the cost per utility of the combined method was higher than either urine microscopic examination or urine Gram stain alone. Urine Gram stain provided the lowest cost per utility. Economically, urine Gram stain is the proper screening tool for presumptive diagnosis of UTI.

  2. 49 CFR 40.31 - Who may collect urine specimens for DOT drug testing?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.31 Who may collect urine specimens for DOT drug testing? (a) Collectors meeting the requirements of this subpart are the only persons authorized to collect urine specimens for DOT drug testing. (b) A collector must meet...

  3. 49 CFR 40.31 - Who may collect urine specimens for DOT drug testing?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.31 Who may collect urine specimens for DOT drug testing? (a) Collectors meeting the requirements of this subpart are the only persons authorized to collect urine specimens for DOT drug testing. (b) A collector must meet...

  4. 49 CFR 40.31 - Who may collect urine specimens for DOT drug testing?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.31 Who may collect urine specimens for DOT drug testing? (a) Collectors meeting the requirements of this subpart are the only persons authorized to collect urine specimens for DOT drug testing. (b) A collector must meet...

  5. 49 CFR 40.31 - Who may collect urine specimens for DOT drug testing?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.31 Who may collect urine specimens for DOT drug testing? (a) Collectors meeting the requirements of this subpart are the only persons authorized to collect urine specimens for DOT drug testing. (b) A collector must meet...

  6. 49 CFR 40.31 - Who may collect urine specimens for DOT drug testing?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Collection Personnel § 40.31 Who may collect urine specimens for DOT drug testing? (a) Collectors meeting the requirements of this subpart are the only persons authorized to collect urine specimens for DOT drug testing. (b) A collector must meet...

  7. Lupus nephritis

    MedlinePlus

    ... time, kidney failure can result. Symptoms Symptoms of lupus nephritis include: Blood in the urine Foamy appearance to urine Swelling (edema) of any area of the body High blood pressure Exams and Tests The health care provider will perform a physical ...

  8. Antibiotic Screening of Urine Culture for Internal Quality Audit at Amrita Hospital, Kochi.

    PubMed

    Suresh, Aswathy; Gopinathan, Anusha; Dinesh, Kavitha R; Kumar, Anil

    2017-07-01

    Urine antimicrobial activity is a seldom analysed laboratory test which greatly impacts the quantification of urine specimens. Presence of antimicrobial activity in the urine reduces the bacterial load in these specimens. Hence, the chances of erroneously reporting insignificant bacteriuria can be reduced on analysis of the antimicrobial activity in urine. The aim of the study was to measure the antimicrobial activity of urine samples obtained from patients in a tertiary care hospital. A total of 100 urine specimens were collected from the study group. Tests like wet mount, Gram staining and culture were performed. Antimicrobial susceptibility testing was done on the bacteria isolated from each specimen. The urine specimens were reported as significant bacteriuria (>105 Colony Forming Unit (CFU)/ml) and insignificant bacteriuria (<105 CFU/ml - clean catch midstream urine; <102 CFU/ml - catheterized urine sample) according to the CFU/ml. Staphylococcus aureus ATCC ® 25923 ™ and Escherichia coli ATCC ® 25922 ™ were used to identify the presence of antimicrobial activity in the urine sample by Urine Anti-Bacterial substance Assay (UABA). McNemar test was used for statistical analysis using Statistical Package for the Social Sciences (SPSS) version 21.0. On analysis of the antimicrobial activity of urine sample with the prior antibiotic history of the patients, 17 were true positives and 43 were true negatives. Twenty six of samples with UABA positivity were culture negative and 28 samples with UABA positivity were culture positive. Sensitivity and specificity of the test was 85% and 53.8% respectively. Accuracy of the test was 60%. The p-value of UABA was <0.001. Enterobacteriaceae was the most common bacterial family isolated from the urine specimens. A total of 85% patients responded to treatment. Presence of antimicrobial activity in urine has a great impact on the interpretation of urine culture reports. Identification of urine antimicrobial activity helps in evaluating the quantification of bacterial growth reported in urine culture. It facilitates speedy recovery of patients by early administration of antibiotics.

  9. Improving the Diagnosis and Treatment of Urinary Tract Infection in Young Children in Primary Care: Results from the DUTY Prospective Diagnostic Cohort Study.

    PubMed

    Hay, Alastair D; Sterne, Jonathan A C; Hood, Kerenza; Little, Paul; Delaney, Brendan; Hollingworth, William; Wootton, Mandy; Howe, Robin; MacGowan, Alasdair; Lawton, Michael; Busby, John; Pickles, Timothy; Birnie, Kate; O'Brien, Kathryn; Waldron, Cherry-Ann; Dudley, Jan; Van Der Voort, Judith; Downing, Harriet; Thomas-Jones, Emma; Harman, Kim; Lisles, Catherine; Rumsby, Kate; Durbaba, Stevo; Whiting, Penny; Butler, Christopher C

    2016-07-01

    Up to 50% of urinary tract infections (UTIs) in young children are missed in primary care. Urine culture is essential for diagnosis, but urine collection is often difficult. Our aim was to derive and internally validate a 2-step clinical rule using (1) symptoms and signs to select children for urine collection; and (2) symptoms, signs, and dipstick testing to guide antibiotic treatment. We recruited acutely unwell children aged under 5 years from 233 primary care sites across England and Wales. Index tests were parent-reported symptoms, clinician-reported signs, urine dipstick results, and clinician opinion of UTI likelihood (clinical diagnosis before dipstick and culture). The reference standard was microbiologically confirmed UTI cultured from a clean-catch urine sample. We calculated sensitivity, specificity, and area under the receiver operator characteristic (AUROC) curve of coefficient-based (graded severity) and points-based (dichotomized) symptom/sign logistic regression models, and we then internally validated the AUROC using bootstrapping. Three thousand thirty-six children provided urine samples, and culture results were available for 2,740 (90%). Of these results, 60 (2.2%) were positive: the clinical diagnosis was 46.6% sensitive, with an AUROC of 0.77. Previous UTI, increasing pain/crying on passing urine, increasingly smelly urine, absence of severe cough, increasing clinician impression of severe illness, abdominal tenderness on examination, and normal findings on ear examination were associated with UTI. The validated coefficient- and points-based model AUROCs were 0.87 and 0.86, respectively, increasing to 0.90 and 0.90, respectively, by adding dipstick nitrites, leukocytes, and blood. A clinical rule based on symptoms and signs is superior to clinician diagnosis and performs well for identifying young children for noninvasive urine sampling. Dipstick results add further diagnostic value for empiric antibiotic treatment. © 2016 Annals of Family Medicine, Inc.

  10. Urine Antigen Detection as an Aid to Diagnose Invasive Aspergillosis.

    PubMed

    Marr, Kieren A; Datta, Kausik; Mehta, Seema; Ostrander, Darin B; Rock, Michelle; Francis, Jesse; Feldmesser, Marta

    2018-04-19

    Establishing rapid diagnoses of invasive aspergillosis (IA) is priority, given poor outcomes of late therapy. Non-culture based tests that detect galactomannan and β-D glucan are available, but are technically cumbersome and rely on invasive sampling (blood or bronchoalveolar lavage). We optimized a lateral flow dipstick assay using the galactofuranose -specific monoclonal antibody (mAb476), which was previously shown to recognize urine antigens after Aspergillus fumigatus pulmonary infection in an`imals. Urine samples were obtained from a cohort of 78 subjects undergoing clinical evaluation for suspected invasive fungal infections, and stored frozen until testing. Urine was processed by centrifugation through desalting columns and exposed to dipsticks. Reviewers blinded to EORTC/MSG clinical diagnoses graded results. Western blots were performed on urines from two subjects to characterize mAb476-reactive antigens. Per-patient sensitivity and specificity for diagnosis of proven or probable IA in the overall cohort was 80% (95% CI: 61.4-92.3) and 92% (95% CI 74-99). In the sub-group with cancer, sensitivity was 89.5% (95% CI 66.7-98.7) and specificity was 90.9% (95% CI 58.7 - 99.8); amongst all others, sensitivity and specificity were 63.6 (95% CI 30.8 - 89.1) and 92.9 (66.1 - 99.8), respectively. Eliminating lung transplant recipients with airway disease increased sensitivity in the non-cancer cohort (85.7%, 95% CI 42.1-99.6%). Semi-quantitative urine assay results correlated with serum galactomannan indices. Western blots demonstrated mAb476-reactive antigens in urine from cases, ranging between 26 - 35kDa in size. Urine testing using mAb476 may be used as an aid to diagnose IA in high-risk patients.

  11. Rapid test by liquid chromatography/tandem mass spectrometry to evaluate equine urine reactivity towards 17beta-OH steroids.

    PubMed

    Fidani, Marco; Casagni, Eleonora; Montana, Marco; Pasello, Emanuela; Pecoraro, Chiara; Gambaro, Veniero

    2006-01-01

    Bacteria frequently found in equine urine samples may cause degradation of 17beta-OH steroids. A simple liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed to evaluate the microbiological contamination of equine urine as a marker of poor storage conditions. Norethandrolone was used as the internal standard, and the linearity, sensitivity, precision and accuracy of the method were evaluated. 17beta-OH oxidation was demonstrated for testosterone, nandrolone, trenbolone and boldenone, but did not occur in alpha-epimers such as alpha-boldenone and epitestosterone, demonstrating the stereoselectivity of the reaction. A rapid test was performed by spiking one of the four 17beta-OH steroids in samples of diluted equine urine. The steroids were transformed into their respective ketones in the presence of bacterial activity. The test allows direct injection of diluted samples into the LC/MS system, without the need for prior extraction. Results show that the best method of storage is freezing at -18 degrees C. Urine specimens should be analyzed as soon as possible after thawing. This allows bacterial degradation of equine urine to be arrested temporarily, so that the urine can be used for qualitative or quantitative analysis of 17beta-OH steroids.

  12. Urine specimen validity test for drug abuse testing in workplace and court settings.

    PubMed

    Lin, Shin-Yu; Lee, Hei-Hwa; Lee, Jong-Feng; Chen, Bai-Hsiun

    2018-01-01

    In recent decades, urine drug testing in the workplace has become common in many countries in the world. There have been several studies concerning the use of the urine specimen validity test (SVT) for drug abuse testing administered in the workplace. However, very little data exists concerning the urine SVT on drug abuse tests from court specimens, including dilute, substituted, adulterated, and invalid tests. We investigated 21,696 submitted urine drug test samples for SVT from workplace and court settings in southern Taiwan over 5 years. All immunoassay screen-positive urine specimen drug tests were confirmed by gas chromatography/mass spectrometry. We found that the mean 5-year prevalence of tampering (dilute, substituted, or invalid tests) in urine specimens from the workplace and court settings were 1.09% and 3.81%, respectively. The mean 5-year percentage of dilute, substituted, and invalid urine specimens from the workplace were 89.2%, 6.8%, and 4.1%, respectively. The mean 5-year percentage of dilute, substituted, and invalid urine specimens from the court were 94.8%, 1.4%, and 3.8%, respectively. No adulterated cases were found among the workplace or court samples. The most common drug identified from the workplace specimens was amphetamine, followed by opiates. The most common drug identified from the court specimens was ketamine, followed by amphetamine. We suggest that all urine specimens taken for drug testing from both the workplace and court settings need to be tested for validity. Copyright © 2017. Published by Elsevier B.V.

  13. Assessment of the use of oral fluid as a matrix for drug monitoring in patients undergoing treatment for opioid addiction.

    PubMed

    Kunkel, Frank; Fey, Elizabeth; Borg, Damon; Stripp, Richard; Getto, Christine

    2015-01-01

    Drug testing is an important clinical tool that is available to physicians who are assessing the effectiveness of drug treatment as well as patient compliance to the administered program. While urine has traditionally been the matrix of choice for drug monitoring, oral fluid, a filtrate of the blood, has shown great promise as an alternative matrix for such applications. Oral fluid collection can be accomplished without the need for highly trained medical staff through the use of a simple, noninvasive oral fluid collection device, which obtains an adequate sample in only a few minutes. There has been a significant amount of research performed on the use of oral fluid for forensic toxicology application; however, more studies assessing the use of oral fluid drug testing are required to validate its ability to achieve clinical drug monitoring goals. Testing for various drugs in oral fluid may yield a different result when compared to the same drugs in urine, requiring an assessment of the utility of oral fluid for such practices. The purpose of this study was to examine the application of oral fluid drug testing in patients undergoing buprenorphine treatment for opioid dependence. A retrospective analysis of drug testing results obtained from 6,928 patients (4,560 unobserved urine collections and 2,368 observed oral fluid collections) monitored for heroin metabolite, amphetamine, benzodiazepines, buprenorphine, tetrahydrocannabinol, cocaine, codeine, hydrocodone, hydromorphone, methadone, morphine, oxycodone, and oxymorphone was completed. Results of this statistical exercise indicated that patients undergoing observed oral fluid collection tested positive more frequently than those unobserved urine collections for several illicit drugs and prescription medications targeted. Oral fluid was shown to detect illicit drug use as well as noncompliance in this patient population under the studied conditions more often than the urine specimens.

  14. Usefulness of enzyme immunoassay (EIA) for screening of anti HIV antibodies in urinary specimens: A comparative analysis.

    PubMed

    Sahni, A K; Nagendra, A; Roy, Partha; Patrikar, S

    2014-07-01

    Standard HIV testing is done using serum or plasma. FDA approved ELISA to screen urine for IgG antibodies to HIV-1 in 1996. It is a simple, noninvasive test and is appropriate for developing countries where health care personnel may not be professionally trained or where clean needles for drawing blood may not always be available. 436 individuals with high-risk behavior and strong clinical suspicion of HIV infection were screened for IgG antibodies to HIV-1 in urine by ELISA. Urine HIV testing was performed by enzyme immunoassay, at the ongoing Voluntary Confidential Counseling and Testing Center (VCCTC) at a large tertiary care microbiology lab. The individuals enrolled for the study had high-risk exposure to the virus and majorities were from a state with a high incidence of HIV infection. In all individuals, both serum and urine were tested for IgG antibodies to HIV-1. Overall, 135 individuals (30.96%) were HIV-positive, of whom 96 (71%) had never previously tested positive; 87% of those who tested positive received their results, and most were referred for medical care. Sensitivity, specificity and predictive values of HIV-1 urine ELISA test kit were determined. Sensitivity was found to be 89.6%; 95% CI [82.9-94.0], specificity 97.3%; 95% CI [94.6-98.8], positive predictive value 93.8%; 95% CI [87.8-97.1] and negative predictive value 95.4%; 95% CI [92.3-97.4]. Efficiency, sensitivity, and specificity of the urine-based screening for HIV-1 test kits were excellent as compared to the reference test.

  15. Comparison of Sofia Legionella FIA and BinaxNOW® Legionella urinary antigen card in two national reference centers.

    PubMed

    Beraud, L; Gervasoni, K; Freydiere, A M; Descours, G; Ranc, A G; Vandenesch, F; Lina, G; Gaia, V; Jarraud, S

    2015-09-01

    The Sofia Legionella Fluorescence Immunoassay (FIA; Quidel) is a recently introduced rapid immunochromatographic diagnostic test for Legionnaires' disease using immunofluorescence technology designed to enhance its sensitivity. The aim of this study was to evaluate its performance for the detection of urinary antigens for Legionella pneumophila serogroup 1 in two National Reference Centers for Legionella. The sensitivity and specificity of the Sofia Legionella FIA test were determined in concentrated and nonconcentrated urine samples, before and after boiling, in comparison with the BinaxNOW® Legionella Urinary Antigen Card (UAC; Alere). Compared with BinaxNOW® Legionella UAC, the sensitivity of the Sofia Legionella test was slightly higher in nonconcentrated urine samples and was identical in concentrated urine samples. The specificity of the Sofia Legionella FIA test was highly reduced by the concentration of urine samples. In nonconcentrated samples, a lack of specificity was observed in 2.3 % of samples, all of them resolved by heat treatment. The Sofia Legionella FIA is a sensitive test for detecting Legionella urinary antigens with no previous urine concentration. However, all positive samples have to be re-tested after boiling to reach a high specificity. The reading is automatized on the Sofia analyzer, which can be connected to laboratory information systems, facilitating accurate and rapid reporting of results.

  16. Urinary free cortisol and cortisone excretion in healthy individuals: influence of water loading.

    PubMed

    Fenske, Martin

    2006-11-01

    The influence of water loading on urinary excretion of free cortisol and cortisone was investigated in healthy men. The results were as follows: water loading tests (intake of 0.25-1.5 L) in a single individual showed that a water load of 1.5 L reliably increased the excretion of urine, free cortisol and cortisone (p < 0.01). Regression analyses gave significant correlations of urine volume with free cortisol and free cortisone, and of free cortisol and free cortisone. Corresponding results were obtained when water loading tests were performed in males who ingested 1.5 L of water (n = 8): the excretion of urine, free cortisol and free cortisone were significantly augmented; correlated was urine volume with free cortisol and free cortisone, and free cortisol with free cortisone. In a third set of tests, volunteers collected one 5 h urine (10:00-15:00 h) after the intake of 3 x 0.1 or 0.5 L at 11:00, 12:00 and 14:00 h. Excretion of urine, free cortisol and free cortisone in males of the low water loading group (3 x 0.1 L) was 0.59 mL/min, and 8.2 or 15.0 microg/5 h; corresponding values in individuals ingesting 3 x 0.5 L of water were 1.5 mL/min (p < 0.01), 12.3 microg/5 h (p > 0.05) and 26.3 microg/5 h (p < 0.02). In summary, urinary free cortisol and cortisone excretion in healthy men depends on urine volume, especially during water diuresis. Thus, interpretation of free cortisol and especially of free cortisone excretion is only possible if subjects strictly control their fluid intake and if urine volume is considered an important pre-analytical parameter-otherwise, interpretation of urinary free cortisol results is difficult and of urinary free cortisone data remains tenuous at best.

  17. The value of a registry negative urine pregnancy test for the prediction of a future unintended pregnancy among young women.

    PubMed

    Rottenstreich, Misgav; Grisaru-Granovsky, Sorina; Rottenstreich, Amihai

    2018-06-01

    Performance of urine pregnancy test in general adolescents' clinic reflects caregiver or woman's concern that there might be a pregnancy. We aimed to assess whether young-unmarried women in whom a negative urine pregnancy test was registered would be at increased risk of a future unintended pregnancy. The study cohort included consecutive women drafted by the Israeli military between 2013 and 2015. The risk of unintended pregnancy was compared between women with a negative urine pregnancy test (n = 2774), the study group, and those in whom urine pregnancy test was not carried out (n = 126,659), the control group. During the study period, 2147 (1.7%) women experienced an unintended pregnancy. The risk of unintended pregnancy was significantly higher in patients in whom a past pregnancy test was negative 4.3% (n = 118), as compared with the control group 1.6% (n = 2028) (odds ratio [OR], 2.7; 95% confidence interval [CI], 2.23-3.26). In multivariate analysis history of a negative pregnancy test results was an independent predictor for a future unintended pregnancy (adjusted OR, 2.0; 95% CI, 1.63-2.52). A history of a negative pregnancy test among young conscripted women is a significant risk indicator for a future unintended pregnancy. Directed efforts should be made in this particular vulnerable group of patients.

  18. Clinical accuracy of point-of-care urine culture in general practice.

    PubMed

    Holm, Anne; Cordoba, Gloria; Sørensen, Tina Møller; Jessen, Lisbeth Rem; Frimodt-Møller, Niels; Siersma, Volkert; Bjerrum, Lars

    2017-06-01

    To assess the clinical accuracy (sensitivity (SEN), specificity (SPE), positive predictive value and negative predictive value) of two point-of-care (POC) urine culture tests for the identification of urinary tract infection (UTI) in general practice. Prospective diagnostic accuracy study comparing two index tests (Flexicult™ SSI-Urinary Kit or ID Flexicult™) with a reference standard (urine culture performed in the microbiological department). General practice in the Copenhagen area patients. Adult female patients consulting their general practitioner with suspected uncomplicated, symptomatic UTI. (1) Overall accuracy of POC urine culture in general practice. (2) Individual accuracy of each of the two POC tests in this study. (3) Accuracy of POC urine culture in general practice with enterococci excluded, since enterococci are known to multiply in boric acid used for transportation for the reference standard. (4) Accuracy based on expert reading of photographs of POC urine cultures performed in general practice. Standard culture performed in the microbiological department was used as reference standard for all four measures. Twenty general practices recruited 341 patients with suspected uncomplicated UTI. The overall agreement between index test and reference was 0.76 (CI: 0.71-0.80), SEN 0.88 (CI: 0.83-0.92) and SPE 0.55 (CI: 0.46-0.64). The two POC tests produced similar results individually. Overall agreement with enterococci excluded was 0.82 (0.77-0.86) and agreement between expert readings of photographs and reference results was 0.81 (CI: 0.76-0.85). POC culture used in general practice has high SEN but low SPE. Low SPE could be due to both misinterpretation in general practice and an imperfect reference standard. Registration number: ClinicalTrials.gov NCT02323087.

  19. Detox agents do not affect the pharmacokinetics of methamphetamine in the rat.

    PubMed

    Lee, Sang Kyu; Kim, Yoon; Suh, Sungill; Suh, Yong Jun; In, Moon Kyo; Kim, Dong-Hyun; Jin, Changbae; Yoo, Hye Hyun

    2009-04-15

    Recently, 'detox' agents have been popularly used as forms of diets or nutritional supplements. Especially, several cases have been reported that these detox agents have been used to mask drug tests among drug abusers. In the present study, capsule and drink types of detox agents were evaluated for their ability to alter the elimination of methamphetamine (MA) in rats. For this study, MA and its major metabolite, amphetamine (AP) in urine samples were determined using LC-tandem mass spectrometry after administration of the detox agents to MA-treated rats. As a result, significant differences were not shown between control and detox-dosed groups in the amounts of MA and AP excreted into urine as well as the volume of excreted urine. This result suggests that the detox agents tested may not affect the metabolism or elimination of MA and further might have minimal effect on narcotics detection in the urine samples of drug abusers.

  20. Cross-Reactivity of Pantoprazole with Three Commercial Cannabinoids Immunoassays in Urine.

    PubMed

    Gomila, Isabel; Barceló, Bernardino; Rosell, Antonio; Avella, Sonia; Sahuquillo, Laura; Dastis, Macarena

    2017-11-01

    Pantoprazole is a frequently prescribed proton pump inhibitor (PPI) commonly utilized in the management of gastrointestinal symptoms. Few substances have proved to cause a false-positive cannabinoid urine screen. However, a case of false-positive urine cannabinoid screen in a patient who received a pantoprazole dose has been recently published. The purpose of this study was to determine the potential cross-reactivity of pantoprazole in the cannabinoid immunoassays: Alere Triage® TOX Drug Screen, KIMS® Cannabinoids II and DRI® Cannabinoids Assay. Drug-free urine to which pantoprazole was added up to 12,000 μg/mL produced negative results in the DRI® Cannabinoids and KIMS® Cannabinoids II. Alere Triage® TOX Drug Screen assay gave positive results at pantoprazole concentrations higher than 1,000 μg/mL. Urine samples from 8 pediatric patients were collected at the beginning of their pantoprazole treatment. Alere Triage® TOX Drug Screen assay produced positive test results in all patient samples and KIMS® Cannabinoids II immunoassay produced positive test results in one patient sample. None patient sample gave a false-positive result when analyzed by the DRI® Cannabinoids Assay. Our findings demonstrate that some cannabinoids immunoassays are susceptible to cross-reaction errors resulting from the presence in urine of pantoprazole and the resulting metabolism of the parent drug. Clinicians should be aware of the possibility of false-positive results for cannabinoids after a pantoprazole treatment. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Reversion of High-level Mecillinam Resistance to Susceptibility in Escherichia coli During Growth in Urine.

    PubMed

    Thulin, Elisabeth; Thulin, Måns; Andersson, Dan I

    2017-09-01

    Mecillinam (amdinocillin) is a β-lactam antibiotic used to treat uncomplicated urinary tract infections (UTIs). We have previously shown that inactivation of the Escherichia coli cysB gene is the major cause of mecillinam resistance (Mec R ) in clinical isolates. In this study, we used different E. coli strains (laboratory and clinical isolates) that were Mec R due to cysB mutations to determine how mecillinam susceptibility was affected during growth in urine compared to growth in the commonly used growth medium Mueller Hinton (MHB). We also examined mecillinam susceptibility when bacteria were grown in urine obtained from 48 different healthy volunteers. Metabolome analysis was done on the urine samples and the association between the mecillinam susceptibility patterns of the bacteria and urine metabolite levels was studied. Two major findings with clinical significance are reported. First, Mec R E. coli cysB mutant strains (both laboratory and clinical isolates) were always more susceptible to mecillinam when grown in urine as compared to laboratory medium, with many strains showing complete phenotypic susceptibility in urine. Second, the degree of reversion to susceptibility varied between urine samples obtained from different individuals. This difference was correlated with osmolality such that in urine with low osmolality the Mec R mutants were more susceptible to mecillinam than in urine with high osmolality. This is the first example describing conditional resistance where a genetically stable antibiotic resistance can be phenotypically reverted to susceptibility by metabolites present in urine. These findings have several important clinical implications regarding the use of mecillinam to treat UTIs. First, they suggest that mecillinam can be used to treat also those clinical strains that are identified as Mec R in standard laboratory tests. Second, the results suggest that testing of mecillinam susceptibility in the laboratory ought to be performed in media that mimics urine to obtain clinically relevant susceptibility testing results. Third, these findings imply that changes in patient behavior, such as increased water intake or use of diuretics to reduce urine osmolality and increased intake of cysteine, might induce antibiotic susceptibility in an infecting Mec R E. coli strain and thereby increase treatment efficiency. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  2. Impact of order set design on urine culturing practices at an academic medical centre emergency department.

    PubMed

    Munigala, Satish; Jackups, Ronald R; Poirier, Robert F; Liang, Stephen Y; Wood, Helen; Jafarzadeh, S Reza; Warren, David K

    2018-01-20

    Urinalysis and urine culture are commonly ordered tests in the emergency department (ED). We evaluated the impact of removal of order sets from the 'frequently ordered test' in the computerised physician order entry system (CPOE) on urine testing practices. We conducted a before (1 September to 20 October 2015) and after (21 October to 30 November 2015) study of ED patients. The intervention consisted of retaining 'urinalysis with reflex to microscopy' as the only urine test in a highly accessible list of frequently ordered tests in the CPOE system. All other urine tests required use of additional order screens via additional mouse clicks. The frequency of urine testing before and after the intervention was compared, adjusting for temporal trends. During the study period, 6499 (28.2%) of 22 948 ED patients had ≥1 urine test ordered. Urine testing rates for all ED patients decreased in the post intervention period for urinalysis (291.5 pre intervention vs 278.4 per 1000 ED visits post intervention, P=0.03), urine microscopy (196.5vs179.5, P=0.001) and urine culture (54.3vs29.7, P<0.001). When adjusted for temporal trends, the daily culture rate per 1000 ED visits decreased by 46.6% (-46.6%, 95% CI -66.2% to -15.6%), but urinalysis (0.4%, 95% CI -30.1 to 44.4%), microscopy (-6.5%, 95% CI -36.0% to 36.6%) and catheterised urine culture rates (17.9%, 95% CI -16.9 to 67.4) were unchanged. A simple intervention of retaining only 'urinalysis with reflex to microscopy' and removing all other urine tests from the 'frequently ordered' window of the ED electronic order set decreased urine cultures ordered by 46.6% after accounting for temporal trends. Given the injudicious use of antimicrobial therapy for asymptomatic bacteriuria, findings from our study suggest that proper design of electronic order sets plays a vital role in reducing excessive ordering of urine cultures. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  3. Enlarged prostate

    MedlinePlus

    ... gland. Other tests may include: Urine flow rate Post-void residual urine test to see how much urine is left in your bladder after you urinate Pressure-flow studies to measure the pressure in the bladder as ...

  4. Chronic Co-species Housing Mice and Rats Increased the Competitiveness of Male Mice.

    PubMed

    Liu, Ying-Juan; Li, Lai-Fu; Zhang, Yao-Hua; Guo, Hui-Fen; Xia, Min; Zhang, Meng-Wei; Jing, Xiao-Yuan; Zhang, Jing-Hua; Zhang, Jian-Xu

    2017-03-01

    Rats are predators of mice in nature. Nevertheless, it is a common practice to house mice and rats in a same room in some laboratories. In this study, we investigated the behavioral and physiological responsively of mice in long-term co-species housing conditions. Twenty-four male mice were randomly assigned to their original raising room (control) or a rat room (co-species-housed) for more than 6 weeks. In the open-field and light-dark box tests, the behaviors of the co-species-housed mice and controls were not different. In a 2-choice test of paired urine odors [rabbit urine (as a novel odor) vs. rat urine, cat urine (as a natural predator-scent) vs. rabbit urine, and cat urine vs. rat urine], the co-species-housed mice were more ready to investigate the rat urine odor compared with the controls and may have adapted to it. In an encounter test, the rat-room-exposed mice exhibited increased aggression levels, and their urines were more attractive to females. Correspondingly, the levels of major urinary proteins were increased in the co-species-housed mouse urine, along with some volatile pheromones. The serum testosterone levels were also enhanced in the co-species-housed mice, whereas the corticosterone levels were not different. The norepinephrine, dopamine, and 5-HT levels in the right hippocampus and striatum were not different between the 2. Our findings indicate that chronic co-species housing results in adaptation in male mice; furthermore, it appears that long-term rat-odor stimuli enhance the competitiveness of mice, which suggests that appropriate predator-odor stimuli may be important to the fitness of prey animals. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  5. Urine concentration test

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/003608.htm Urine concentration test To use the sharing features on this page, please enable JavaScript. A urine concentration test measures the ability of the kidneys ...

  6. Chronic opioid therapy risk reduction initiative: impact on urine drug testing rates and results.

    PubMed

    Turner, Judith A; Saunders, Kathleen; Shortreed, Susan M; Rapp, Suzanne E; Thielke, Stephen; LeResche, Linda; Riddell, Kim M; Von Korff, Michael

    2014-02-01

    In response to epidemic levels of prescription opioid overdose, abuse, and diversion, routine urine drug tests (UDTs) are recommended for patients receiving chronic opioid therapy (COT) for chronic pain. However, UDT ordering for COT patients is inconsistent in primary care, and little is known about how to increase UDT ordering or the impact of increased testing on rates of aberrant results. To compare rates and results of UDTs for COT patients before versus after implementation of an opioid risk reduction initiative in a large healthcare system. Pre-post observational study. Group Health patients on COT October 2008-September 2009 (N = 4,821), October 2009-September 2010 (N = 5,081), and October 2010-September 2011 (N = 5,498). Multi-faceted opioid risk reduction initiative. Annual rates of UDTs and UDT results. Half of COT patients received at least one UDT in the year after the initiative was implemented, compared to only 7 % 2 years prior. The adjusted odds of COT patients having at least one UDT in the first year of the opioid initiative were almost 16 times (adjusted OR = 15.79; 95 % CI: 13.96-17.87) those 2 years prior. The annual rate of UDT detection of marijuana and illicit drugs did not change (12.6 % after initiative implementation), and largely reflected marijuana use (detected in 11.1 % of all UDTs in the year after initiative implementation). In the year after initiative implementation, 10.7 % of UDTs were negative for opioids. The initiative appeared to dramatically increase urine drug testing of COT patients in the healthcare system without impacting rates of aberrant results. The large majority of aberrant results reflected marijuana use or absence of opioids in the urine. The utility of increased urine drug testing for COT patient safety and prevention of diversion remains uncertain.

  7. Nappy pad urine samples for investigation and treatment of UTI in young children: the ‘DUTY’ prospective diagnostic cohort study

    PubMed Central

    Butler, Christopher C; Sterne, Jonathan AC; Lawton, Michael; O’Brien, Kathryn; Wootton, Mandy; Hood, Kerenza; Hollingworth, William; Little, Paul; Delaney, Brendan C; van der Voort, Judith; Dudley, Jan; Birnie, Kate; Pickles, Timothy; Waldron, Cherry-Ann; Downing, Harriet; Thomas-Jones, Emma; Lisles, Catherine; Rumsby, Kate; Durbaba, Stevo; Whiting, Penny; Harman, Kim; Howe, Robin; MacGowan, Alasdair; Fletcher, Margaret; Hay, Alastair D

    2016-01-01

    Background The added diagnostic utility of nappy pad urine samples and the proportion that are contaminated is unknown. Aim To develop a clinical prediction rule for the diagnosis of urinary tract infection (UTI) based on sampling using the nappy pad method. Design and setting Acutely unwell children <5 years presenting to 233 UK primary care sites. Method Logistic regression to identify independent associations of symptoms, signs, and urine dipstick test results with UTI; diagnostic utility quantified as area under the receiver operator curves (AUROC). Nappy pad rule characteristics, AUROC, and contamination, compared with findings from clean-catch samples. Results Nappy pad samples were obtained from 3205 children (82% aged <2 years; 48% female), culture results were available for 2277 (71.0%) and 30 (1.3%) had a UTI on culture. Female sex, smelly urine, darker urine, and the absence of nappy rash were independently associated with a UTI, with an internally-validated, coefficient model AUROC of 0.81 (0.87 for clean-catch), which increased to 0.87 (0.90 for clean-catch) with the addition of dipstick results. GPs’ ‘working diagnosis’ had an AUROC 0.63 (95% confidence intervals [CI] = 0.53 to 0.72). A total of 12.2% of nappy pad and 1.8% of clean-catch samples were ‘frankly contaminated’ (risk ratio 6.66; 95% CI = 4.95 to 8.96; P<0.001). Conclusion Nappy pad urine culture results, with features that can be reported by parents and dipstick tests, can be clinically useful, but are less accurate and more often contaminated compared with clean-catch urine culture. PMID:27364678

  8. Ground Test of the Urine Processing Assembly for Accelerations and Transfer Functions

    NASA Technical Reports Server (NTRS)

    Houston, Janice; Almond, Deborah F. (Technical Monitor)

    2001-01-01

    This viewgraph presentation gives an overview of the ground test of the urine processing assembly for accelerations and transfer functions. Details are given on the test setup, test data, data analysis, analytical results, and microgravity assessment. The conclusions of the tests include the following: (1) the single input/multiple output method is useful if the data is acquired by tri-axial accelerometers and inputs can be considered uncorrelated; (2) tying coherence with the matrix yields higher confidence in results; (3) the WRS#2 rack ORUs need to be isolated; (4) and future work includes a plan for characterizing performance of isolation materials.

  9. Urine specific gravity test

    MedlinePlus

    ... medlineplus.gov/ency/article/003587.htm Urine specific gravity test To use the sharing features on this page, please enable JavaScript. Urine specific gravity is a laboratory test that shows the concentration ...

  10. Integrated water management system - Description and test results. [for Space Station waste water processing

    NASA Technical Reports Server (NTRS)

    Elden, N. C.; Winkler, H. E.; Price, D. F.; Reysa, R. P.

    1983-01-01

    Water recovery subsystems are being tested at the NASA Lyndon B. Johnson Space Center for Space Station use to process waste water generated from urine and wash water collection facilities. These subsystems are being integrated into a water management system that will incorporate wash water and urine processing through the use of hyperfiltration and vapor compression distillation subsystems. Other hardware in the water management system includes a whole body shower, a clothes washing facility, a urine collection and pretreatment unit, a recovered water post-treatment system, and a water quality monitor. This paper describes the integrated test configuration, pertinent performance data, and feasibility and design compatibility conclusions of the integrated water management system.

  11. A pilot study on the use of natural calcium isotope (44Ca/40Ca) fractionation in urine as a proxy for the human body calcium balance.

    PubMed

    Heuser, Alexander; Eisenhauer, Anton

    2010-04-01

    We explored the possibility of using natural calcium (Ca) isotope variations in the urine (delta(44/40)Ca(urine)) as a proxy for the Ca balance in the human body. We chose two test persons extremely different in their health status, gender and age (4-year-old healthy boy and a 60-year-old woman known to suffer from osteoporosis). During a 5 day interval the Ca isotope composition of the individual diet (delta(44/40)Ca(diet)) was monitored for both test persons to be in general agreement to the Ca isotope composition of the normal western European diet ( approximately -1.02+/-0.1 per thousand). However, measurements showed that (1) delta(44/40)Ca(urine) of both test persons are approximately 1.37 and approximately 2.49 per thousand, respectively, heavier than delta(44/40)Ca(diet) and that (2) the delta(44/40)Ca(urine-boy) is approximately 1.1 per thousand heavier when compared to the value of the woman. The individual offset between diet and test persons is interpreted to reflect individual Ca reabsorption rates in the kidneys being the result of Rayleigh type Ca isotope fractionation related to the partitioning of Ca between the glomerular filtrate and filtered residue. The relative difference between delta(44/40)Ca(urine-boy) and delta(44/40)Ca(urine-woman) of approximately 1.1 per thousand may reflect individual differences in the balance of bone mineralization and demineralization processes related to age, gender and health status. By arbitrarily defining an equilibrium value for Delta(44/40)Ca(diet-urine) of -1.93 per thousand being the arithmetic mean of delta(44/40)Ca(urine) for both test persons the measured delta(44/40)Ca(urine) values may be applied to model the individual bone mineralization and demineralization processes in a qualitative way. Note, second order influences of intestinal Ca absorption during sequestration of Ca between intestine and blood have to be subject of further studies. Copyright 2009 Elsevier Inc. All rights reserved.

  12. Development of a nanogold-based immunochromatographic assay for detection of morphine in urine using the Amor-HK16 monoclonal antibody.

    PubMed

    Dehghannezhad, Ardeshir; Paknejad, Maliheh; Rasaee, Mohammad Javad; Omidfar, Kobra; Seyyed Ebrahimi, Shadi Sadat; Ghahremani, Hossein

    2012-12-01

    A simple, rapid competitive immunochromatography (ICG) strip test was developed to detect morphine in urine samples using a monoclonal antibody produced in-house and conjugated to gold nanoparticles. Hybridoma cells were cultured and the Amor-HK16 monoclonal antibody against morphine was obtained from the supernatant after purification by salting out and passing through a Protein G-Agarose affinity column. Morphine was obtained from morphine sulfate and a C6-hemisuccinate derivative of morphine was prepared, conjugated to bovine serum albumin, and immobilized to a nitrocellulose membrane as the test line. Goat anti-mouse antibody was used as a binder in the control line in the detection zone of the strip. Colloidal gold particles of diameter approximately 20 nm were prepared and conjugated to the monoclonal antibody. The detection limit of the test strip was found to be 2000 ng/mL of morphine in urine samples. Reliability was determined by performing the ICG test on 103 urine samples and comparing the results with those obtained by thin-layer chromatography. The sensitivity of the test was 100%, and the analysis time for the assay was approximately 5 min. The new ICG method was adequately sensitive and accurate for the rapid screening of morphine in urine.

  13. Development testing of a shuttle urine collection system

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Flight tests conducted in December 1973 demonstrated the ability of an unisexual urine collection subsystem to function in a zero-g environment. The urinal, which could be adjusted with three degrees of freedom, accommodated 16 female test subjects with a wide range of stature, as well as five male test subjects. The urinal was in intimate contact with the female and was contoured to form an effective air seal at the periphery. When positioned 2-4 inches forward, the urinal could be used for male collection and contact was not required.

  14. Impaired insight in cocaine addiction: laboratory evidence and effects on cocaine-seeking behaviour

    PubMed Central

    Maloney, Thomas; Parvaz, Muhammad A.; Alia-Klein, Nelly; Woicik, Patricia A.; Telang, Frank; Wang, Gene-Jack; Volkow, Nora D.; Goldstein, Rita Z.

    2010-01-01

    Neuropsychiatric disorders are often characterized by impaired insight into behaviour. Such an insight deficit has been suggested, but never directly tested, in drug addiction. Here we tested for the first time this impaired insight hypothesis in drug addiction, and examined its potential association with drug-seeking behaviour. We also tested potential modulation of these effects by cocaine urine status, an individual difference known to impact underlying cognitive functions and prognosis. Sixteen cocaine addicted individuals testing positive for cocaine in urine, 26 cocaine addicted individuals testing negative for cocaine in urine, and 23 healthy controls completed a probabilistic choice task that assessed objective preference for viewing four types of pictures (pleasant, unpleasant, neutral and cocaine). This choice task concluded by asking subjects to report their most selected picture type; correspondence between subjects’ self-reports with their objective choice behaviour provided our index of behavioural insight. Results showed that the urine positive cocaine subjects exhibited impaired insight into their own choice behaviour compared with healthy controls; this same study group also selected the most cocaine pictures (and fewest pleasant pictures) for viewing. Importantly, however, it was the urine negative cocaine subjects whose behaviour was most influenced by insight, such that impaired insight in this subgroup only was associated with higher cocaine-related choice on the task and more severe actual cocaine use. These findings suggest that interventions to enhance insight may decrease drug-seeking behaviour, especially in urine negative cocaine subjects, potentially to improve their longer-term clinical outcomes. PMID:20395264

  15. Direct urine polymerase chain reaction for chlamydia and gonorrhoea: a simple means of bringing high-throughput rapid testing to remote settings?

    PubMed

    Rahimi, Frashta; Goire, Namraj; Guy, Rebecca; Kaldor, John M; Ward, James; Nissen, Michael D; Sloots, Theo P; Whiley, David M

    2013-08-01

    Background Rapid point-of-care tests (POCTs) for chlamydia (Chlamydia trachomatis) and gonorrhoea (Neisseria gonorrhoeae) have the potential to confer health benefits in certain populations even at moderate sensitivities; however, suitable POCTs for these organisms are currently lacking. In this study, we investigated the use of direct urine polymerase chain reaction (PCR), with the view of implementing a simplified PCR strategy for high-throughput chlamydia and gonorrhoea screening in remote settings. Briefly, a simple dilution of the urine was performed before adding it directly to a real-time PCR reaction. The method was evaluated using 134 stored urine specimens that had been submitted for chlamydia and gonorrhoea testing and had been tested using a commercial C. trachomatis and N. gonorrhoeae PCR method. These included samples that were PCR-positive for chlamydia (n=87), gonorrhoea (n=16) or both (n=2). Direct urine testing was conducted using previously described in-house real-time PCR methods for C. trachomatis and N. gonorrhoeae as well as for recognised N.gonorrhoeae antimicrobial resistance mechanisms. The overall sensitivities and specificities of the direct urine PCR were 78% and 100% for chlamydia, and 83% and 100% for gonorrhoea. N.gonorrhoeae penicillin and quinolone resistance mechanisms were characterised in 14 of the 18 N. gonorrhoeae-positive samples. The results of this study show that the simplified PCR strategy may be a feasible approach for rapid screening and improving chlamydia and gonorrhoea treatment in remote settings.

  16. The uriscreen test to detect significant asymptomatic bacteriuria during pregnancy.

    PubMed

    Teppa, Roberto J; Roberts, James M

    2005-01-01

    Asymptomatic bacteriuria (ASB) occurs in 2-11% of pregnancies and it is a clear predisposition to the development of acute pyelonephritis, which, in turn, poses risk to mother and fetus. Treatment of bacteriuria during pregnancy reduces the incidence of pyelonephritis. Therefore, it is recommended to screen for ASB at the first prenatal visit. The gold standard for detection of bacteriuria during pregnancy is urine culture, but this test is expensive, time-consuming, and labor-intensive. To determine the reliability of an enzymatic urine screening test (Uriscreen; Savyon Diagnostics, Ashdod, Israel) for detecting ASB in pregnancy. Catheterized urine samples were collected from 150 women who had routine prenatal screening for ASB. Patients with urinary symptoms, active vaginal bleeding, or who were previously on antibiotics therapy were excluded from the study. Sensitivity, specificity, and the positive and negative predictive values for the Uriscreen were estimated using urine culture as the criterion standard. Urine cultures were considered positive if they grew >10(5) colony-forming units of a single uropathogen. Twenty-eight women (18.7%) had urine culture results indicating significant bacteriuria, and 17 of these 28 specimens had positive enzyme activity. Of 122 samples with no growth, 109 had negative enzyme activity. Sensitivity, specificity, and positive and negative predictive values for the Uriscreen test were 60.7% (+/-18.1), 89.3% (+/-5.6), 56.6%, and 90.8%, respectively. The Uriscreen test had inadequate sensitivity for rapid screening of bacteriuria in pregnancy.

  17. Automated Microbiological Detection/Identification System

    PubMed Central

    Aldridge, C.; Jones, P. W.; Gibson, S.; Lanham, J.; Meyer, M.; Vannest, R.; Charles, R.

    1977-01-01

    An automated, computerized system, the AutoMicrobic System, has been developed for the detection, enumeration, and identification of bacteria and yeasts in clinical specimens. The biological basis for the system resides in lyophilized, highly selective and specific media enclosed in wells of a disposable plastic cuvette; introduction of a suitable specimen rehydrates and inoculates the media in the wells. An automated optical system monitors, and the computer interprets, changes in the media, with enumeration and identification results automatically obtained in 13 h. Sixteen different selective media were developed and tested with a variety of seeded (simulated) and clinical specimens. The AutoMicrobic System has been extensively tested with urine specimens, using a urine test kit (Identi-Pak) that contains selective media for Escherichia coli, Proteus species, Pseudomonas aeruginosa, Klebsiella-Enterobacter species, Serratia species, Citrobacter freundii, group D enterococci, Staphylococcus aureus, and yeasts (Candida species and Torulopsis glabrata). The system has been tested with 3,370 seeded urine specimens and 1,486 clinical urines. Agreement with simultaneous conventional (manual) cultures, at levels of 70,000 colony-forming units per ml (or more), was 92% or better for seeded specimens; clinical specimens yielded results of 93% or better for all organisms except P. aeruginosa, where agreement was 86%. System expansion in progress includes antibiotic susceptibility testing and compatibility with most types of clinical specimens. Images PMID:334798

  18. Does random urine drug testing reduce illicit drug use in chronic pain patients receiving opioids?

    PubMed

    Manchikanti, Laxmaiah; Manchukonda, Rajeev; Pampati, Vidyasagar; Damron, Kim S; Brandon, Doris E; Cash, Kim A; McManus, Carla D

    2006-04-01

    Prescription drug abuse and illicit drug use are common in chronic pain patients. Adherence monitoring with screening tests, and urine drug testing, periodic monitoring with prescription monitoring programs, has become a common practice in recent years. Random drug testing for appropriate use of opioids and use of illicit drugs is often used in pain management practices. Thus, it is expected that random urine drug testing will deter use of illicit drugs, and also improve compliance. To study the prevalence of illicit drug use in patients receiving opioids for chronic pain management and to compare the results of illicit drug use with the results from a previous study. A prospective, consecutive study. Interventional pain management practice setting in the United States. A total of 500 consecutive patients on opioids, considered to be receiving stable doses of opioids supplemental to their interventional techniques, were studied by random drug testing. Testing was performed by rapid drug screen. Results were considered positive if one or more of the monitored illicit drugs including cocaine, marijuana (THC), methamphetamine or amphetamines were present. Illicit drug use was evident in 80 patients, or 16%, with marijuana in 11%, cocaine in 5%, and methamphetamine and/or amphetamines in 2%. When compared with previous data, the overall illicit drug use was significantly less. Illicit drug use in elderly patients was absent. The prevalence of illicit drug abuse in patients with chronic pain receiving opioids continues to be a common occurence. This study showed significant reductions in overall illicit drug use with adherence monitoring combined with random urine drug testing.

  19. Urine human papillomavirus prevalence in women with high-grade cervical lesions.

    PubMed

    Nicolau, P; Mancebo, G; Agramunt, S; Solé-Sedeño, J M; Bellosillo, B; Muset, M M; Lloveras, B; Alameda, F; Carreras, R

    2014-12-01

    To determine the prevalence of human papillomavirus (HPV) in urine samples from women with high-grade cervical lesions. Secondary objectives are to identify the influence of socio-demographic factors and the different genotypes with urinary HPV positivity. 75 women with a positive biopsy for CIN2+ were included in the study from October 2010 to July 2011. A sample of urine was collected immediately before conization at the outpatient clinic. We analyzed the presence of HPV using a PCR technique. The mean age of the patients was 34.8 years (range 24 to 61). All patients had histological CIN2+, of whom 54.67% had CIN3. The prevalence of HPV in urine test was 58.82% in CIN2 population versus 78.05% in CIN3 patients (p 0.072). 31 different genotypes were found. The most frequent HPV genotype was 16-HPV, which was identified in 58% of women with positive HPV-DNA in urine samples. No demographic characteristics were significantly associated to urinary HPV prevalence. Most of the patients with CIN2+ showed positive results for urine HPV test. The prevalence of positive urinary HPV test was higher for patients with CIN3. HPV urine detection could be considered as an acceptable option for high-risk population who skip regular screening programs. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  20. 24-hour urine copper test

    MedlinePlus

    ... medlineplus.gov/ency/article/003604.htm 24-hour urine copper test To use the sharing features on this page, please enable JavaScript. The 24-hour urine copper test measures the amount of copper in ...

  1. Medullary cystic kidney disease

    MedlinePlus

    ... Tests that may be done include: 24-hour urine volume and electrolytes Blood urea nitrogen (BUN) Complete blood count (CBC) Creatinine blood test Creatinine clearance -- blood and urine Uric acid blood test Urine specific gravity (will ...

  2. Determinants of practice patterns in pediatric UTI management.

    PubMed

    Selekman, R E; Allen, I E; Copp, H L

    2016-10-01

    Urinary tract infection (UTI) affects 10% of girls and 3% of boys by age 16. Both the American Academy of Pediatrics and National Institute for Health and Clinical Excellence Guidelines recommend urine testing prior to initiation of antibiotic treatment and the use of local antibiograms to guide empiric antibiotic therapy. Urine culture results not only provide the opportunity to halt empiric therapy if there is no bacterial growth, but also allow for tailoring of broad-spectrum therapy. Additionally, the use of antiobiograms improves empiric antibiotic selection based on local resistance patterns. However, execution of guideline recommendations has proved challenging. Understanding barriers in implementation is critical to developing targeted interventions aimed to improve adherence to these guidelines. The present study sought to investigate practice patterns and factors that influence urine testing and antibiogram use in the setting of empiric antibiotic treatment of UTI in children to ultimately improve adherence to UTI management guidelines. A random, national sample of physicians caring for children was surveyed from the American Medical Association Masterfile. Participants were queried regarding practice type, length of time in practice, factors influencing urine testing, urine specimen collection method, and antibiogram utilization. Logistic regression was used to assess factors associated with use of urine testing, bagged specimens, and antibiograms. Of respondents who acknowledged contact by surveyors, 47% completed the survey (n = 366). Most respondents (84%) obtain urinalysis and culture prior to treatment for UTI. Physicians report they would more likely order testing if the specimen were easier to collect (46%) and if results were available immediately (48%) (Table). Urine collection by bag was more common in circumcised boys (>30%) compared with girls (20%) and uncircumcised boys (20%) (P = 0.02). The most common reasons for collection by bag were parental refusal for (49%) and difficulty with (42%) catheterization (Table). Of the 70% of respondents reporting antibiogram access (n = 256), 50% report its use the majority of the time with empiric prescription (n = 128). While most practitioners report following guidelines to obtain urine testing prior to antibiotic prescription for UTI, urine collection by bag is common. Additionally, <50% of practitioners adhere to guideline recommendations for empiric antibiotic selection based on local antibiograms. Interventions to improve adherence to UTI management guidelines should focus on (1) improving catheterization practices, (2) educating parents regarding the value of catheterization, and (3) incorporating local antibiograms into electronic medical records. Copyright © 2016 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  3. Screening and treating asymptomatic bacteriuria in pregnancy.

    PubMed

    Lumbiganon, Pisake; Laopaiboon, Malinee; Thinkhamrop, Jadsada

    2010-04-01

    Asymptomatic bacteriuria (ASB) in pregnancy, if left undiagnosed and appropriately treated can lead to acute pyelonephritis in mothers and low birth weight in infants. Urine culture is the gold standard for diagnosing ASB. Unfortunately, urine culture is limitedly available. The present review aims at evaluating performance of various screening tests and effectiveness of antibiotic regimens for ASB. Positive dipslide test is very likely to have a definitive diagnosis of ASB, whereas a negative result effectively rules out ASB. Available evidences regarding the performance of urine dipstick are still conflicting, it is currently not appropriate to recommend urine dipstick for screening ASB in pregnancy. Choice of antibiotics should be guided by antimicrobial susceptibility testing whenever possible. Nitrofurantoin seems to be antibiotic of choice for ASB in pregnancy. Seven-day regimen of antibiotics gives a better microbiological cure rate but no difference in important clinical outcomes compared with 1-day regimen. Dipslide culture is a promising screening test for ASB. Pregnant women with ASB should be treated with 7-day regimen of antibiotics, although 1-day regimen might be appropriate in some settings. More research is needed for identifying appropriate screening tests for ASB.

  4. Factitious diarrhea induced by stimulant laxatives: accuracy of diagnosis by a clinical reference laboratory using thin layer chromatography.

    PubMed

    Shelton, Joseph H; Santa Ana, Carol A; Thompson, Donald R; Emmett, Michael; Fordtran, John S

    2007-01-01

    Surreptitious ingestion of laxatives can lead to serious factitious diseases that are difficult to diagnose. Most cases involve ingestion of bisacodyl or senna. Thin layer chromatography (TLC) of urine or stool is the only commercially available test for these laxatives. Such testing is considered highly reliable, but its accuracy in clinical practice is unknown. Our aim was to evaluate the reliability of TLC laxative testing by a clinical reference laboratory in the United States. Diarrhea was induced in healthy volunteers by ingestion of bisacodyl, senna, or a control laxative (n = 11 for each laxative group). Samples of urine and diarrheal stool were sent in blinded fashion to the clinical reference laboratory for bisacodyl and senna analysis. TLC testing for bisacodyl-induced diarrhea revealed a sensitivity of 73% and specificity of 91% when urine was tested and sensitivity and specificity of 91% and 96%, respectively, when stool was analyzed. When diarrhea was induced by senna, the TLC assay for senna failed to identify even a single urine or stool specimen as positive (zero% sensitivity). Considering the expected prevalence of surreptitious laxative abuse in patients with chronic idiopathic diarrhea (2.4%-25%, depending on the clinical setting), TLC of urine or stool for bisacodyl by this reference laboratory would often produce misleading results, and testing for senna would have no clinical value. The major problems are false-positive tests for bisacodyl and false-negative tests for senna.

  5. Mobile Technology Application for Improved Urine Concentration Measurement Pilot Study.

    PubMed

    Walawender, Laura; Patterson, Jeremy; Strouse, Robert; Ketz, John; Saxena, Vijay; Alexy, Emily; Schwaderer, Andrew

    2018-01-01

    Objectives: Low hydration has a deleterious effect on many conditions. In the absence of a urine concentrating defect, urine concentration is a marker of hydration status. However, markers to evaluate hydration status have not been well studied in children. The objectives of this paper are to compare measures of thirst and urine concentration in children and to develop a novel mobile technology application to measure urine concentration. Study Design: Children age 12-17 years were selected ( n = 21) for this pilot study. Thirst perception, specific gravity (automated dipstick analysis and refractometer), and urine color scale results were correlated to urine osmolality. The technology department developed a mobile technology camera application to measure light penetrance into urine which was tested on 25 random anonymized urine samples. Results: The patients' thirst perception and color scale as well as two researchers color scale did not significantly correlate with osmolality. Correlation between osmolality and hydration markers resulted in the following Pearson coefficients: SG automated dipstick, 0.61 ( P 0.003); SG refractometer, 0.98 ( P < 0.0001); urine color scale (patient), 0.37 ( P 0.10), and light penetrance, -0.77 ( P < 0.0001). The correlation of light penetrance with osmolality was stronger than all measures except SG by refractometer and osmolality. Conclusion: The mobile technology application may be a more accurate tool for urine concentration measurement than specific gravity by automated dipstick, subjective thirst, and urine color scale, but lags behind specific gravity measured by refractometer. The mobile technology application is a step toward patient oriented hydration strategies.

  6. Epidemiology of alcohol and other drug use among motor vehicle crash victims admitted to a trauma center.

    PubMed

    Walsh, J Michael; Flegel, Ron; Cangianelli, Leo A; Atkins, Randolph; Soderstrom, Carl A; Kerns, Timothy J

    2004-09-01

    The objectives of this research were to (1) determine the incidence and prevalence of alcohol and other drug use among motor vehicle crash (MVC) victims admitted to a regional Level-I trauma center, and (2) to examine the utility of using a rapid point-of-collection (POC) drug-testing device to identify MVC patients with drug involvement. Blood and urine specimens were routinely collected per clinical protocol for each MVC victim at the time of admission. Blood alcohol concentration (BAC) levels were determined per standard clinical protocol. Clinical urine specimens were routinely split so that a POC drug-testing device for the detection of commonly abused drugs (Marijuana, Cocaine, Amphetamines, Methamphetamines, and Opiates) could be compared to that of the standard hospital laboratory analysis of each urine specimen (which also included Barbiturates and Benzodiazepines). In the six-month period of this study, nearly two-thirds of trauma center admissions were victims of motor vehicle crashes. During this time, blood and urine was collected from 322 MVC victims. Toxicology results indicated that 59.3% of MVC victims tested positive for either commonly abused drugs or alcohol. More patients tested positive for drug use than tested positive for alcohol, with 33.5% testing positive for drug use only, 15.8% testing positive for alcohol use only, and 9.9% testing positive for both drugs and alcohol. Less than half (45.2%) of the substance-abusing patients in this study would have been identified by an alcohol test alone. After alcohol, marijuana and benzodiazepines were the most frequently detected drugs. Point of collection (POC) test results correlated well with laboratory results and provide important information to initiate rapid intervention/treatment for substance use problems among injured patients.

  7. HPV Testing from Dried Urine Spots as a Tool for Cervical Cancer Screening in Low-Income Countries.

    PubMed

    Frati, Elena Rosanna; Martinelli, Marianna; Fasoli, Ester; Colzani, Daniela; Bianchi, Silvia; Binda, Sandro; Olivani, Pierfranco; Tanzi, Elisabetta

    2015-01-01

    Nowadays, several screening strategies are available to prevent cervical cancer, but inadequate resources, sociocultural barriers, and sampling issues impede their success in low-income countries. To overcome these issues, this study aimed to evaluate the performance of human papillomavirus (HPV) testing from dried urine spots (DUS). Eighty-eight urine samples (including 56 HPV DNA positive specimens) were spotted on filter paper, dried, and stored in paper-bags. HPV DNA was detected from the DUS after 1 week and 4 weeks of storage using a polymerase chain reaction (PCR) assay. The sensitivity, specificity, and concordance of the DUS-based HPV test were evaluated by comparing the results with those of HPV testing on fresh urine samples as the gold standard. The sensitivity of the test was 98.21% (95% CI: 90.56-99.68) for DUS stored for 1 week and 96.42% (95% CI: 87.88-99.01) for DUS stored for 4 weeks. The specificity was 100% (95% CI: 89.28-100) at both time points. The concordance between DUS and fresh urine HPV testing was "almost perfect" using the κ statistic. These preliminary data suggest that a DUS-based assay could bypass sociocultural barriers and sampling issues and therefore could be a suitable, effective tool for epidemiological surveillance and screening programs, especially in low-income countries.

  8. HPV Testing from Dried Urine Spots as a Tool for Cervical Cancer Screening in Low-Income Countries

    PubMed Central

    Olivani, Pierfranco

    2015-01-01

    Nowadays, several screening strategies are available to prevent cervical cancer, but inadequate resources, sociocultural barriers, and sampling issues impede their success in low-income countries. To overcome these issues, this study aimed to evaluate the performance of human papillomavirus (HPV) testing from dried urine spots (DUS). Eighty-eight urine samples (including 56 HPV DNA positive specimens) were spotted on filter paper, dried, and stored in paper-bags. HPV DNA was detected from the DUS after 1 week and 4 weeks of storage using a polymerase chain reaction (PCR) assay. The sensitivity, specificity, and concordance of the DUS-based HPV test were evaluated by comparing the results with those of HPV testing on fresh urine samples as the gold standard. The sensitivity of the test was 98.21% (95% CI: 90.56–99.68) for DUS stored for 1 week and 96.42% (95% CI: 87.88–99.01) for DUS stored for 4 weeks. The specificity was 100% (95% CI: 89.28–100) at both time points. The concordance between DUS and fresh urine HPV testing was “almost perfect” using the κ statistic. These preliminary data suggest that a DUS-based assay could bypass sociocultural barriers and sampling issues and therefore could be a suitable, effective tool for epidemiological surveillance and screening programs, especially in low-income countries. PMID:26180790

  9. Asymptomatic bacteriuria in pregnant women attending Boo-Ali Hospital Tehran Iran: Urine analysis vs. urine culture.

    PubMed

    Etminan-Bakhsh, Mina; Tadi, Sima; Darabi, Roksana

    2017-11-01

    Asymptomatic bacteriuria is one of the common problems in pregnancy. Asymptomatic bacteriuria is associated with pyelonephritis, preterm labor and low birth weight infants. The physiological and anatomical changes in pregnancy facilitate urinary tract infection (UTI) during pregnancy. Several tests are available for diagnosis of asymptomatic bacteriuria. The urine culture is a gold standard diagnostic test for asymptomatic bacteriuria but it is expensive and time-consuming. Screening methods may be useful in detecting high-risk pregnant women for asymptomatic bacteriuria. The aim of the present study was to compare urine analysis as a rapid screening test to urine culture in diagnosis of asymptomatic bacteriuria. A total of 123 pregnant women attending the obstetrics clinic of Boo-Ali hospital in Tehran, Iran from March 2013 to September 2014 were included in the present diagnostic cross-sectional study. One hundred twenty three mid-stream urine samples were inoculated into cultures and were processed by dipstick (nitrite test and leucocyte esterase test) and microscopic pus cell count. The sensitivity, specificity, positive predictive value and negative predictive value of nitrite test, leucocyte esterase test and microscopic pus cell count were compared with urine culture in diagnosis of asymptomatic bacteriuria by using SPSS version 19. Of 123 urine samples, significant asymptomatic bacteriuria (≥10 4 cfu/Ml) was detected in 8 (6.5%) subjects. The sensitivity and specificity of nitrite test were 37% and 100% respectively. The sensitivity of pus cell count alone and leucocyte esterase test alone were 100% but the specificity of them were 64% and 65% respectively. We found high negative predictive value by Pus cell count and the leucocyte esterase test (100%) and low positive predictive value by them (16% and 17% respectively). Urine culture is the most useful test for diagnosis of asymptomatic bacteriuria. None of our screening tests had a sensitivity and specificity of 100%, whereas we can only refer the pregnant women with positive leucocyte esterase test and significant pyuria to the urine culture.

  10. Urobilinogen in Urine

    MedlinePlus

    ... Why do I need a urobilinogen in urine test? Your health care provider may have ordered this test as part ... skin What happens during a urobilinogen in urine test? Your health care provider will need to collect a sample of ...

  11. Improved diagnostics of chronic inflammatory prostatitis.

    PubMed

    Kulchavenya, E; Azizoff, A; Brizhatyuk, E; Khomyakov, V; Kholtobin, D; Breusoff, A; Naber, K G

    2012-12-01

    Prostatitis is a prevalent condition that encompasses a large array of clinical symptoms with significant impacts on men's life. The diagnosis and treatment of this disorder presents numerous challenges for urologists, most notably, a lack of specific and effective diagnostic methods. To improve the diagnostics the comparison of classic 4-glass test Meares and Stamey, 2-glass tests and 3-glass test was conducted in 177 men suspicious for chronic prostatitis. Four-glass test is uncomfortable both for patients and doctors, and leads to contamination of urine with prostatic secretion. Two-glass test is insufficiently effective too. Three-glass test (three urine specimens obtained from one continuous micturition stream) gives more adequate results and may be used for screening. Three-glass test as screening test with the option of an additional EPS investigation in those patients the final diagnosis of chronic prostatitis has to be confirmed is more convenient for patients and doctors than the standard M&S 4-glass test and "false-positive" (contaminated with EPS) midstream urine results are avoided thus improving discrimination of urethritis, cystitis and prostatitis. Therefore, we recommend the KE 3-glass test as a new standard for screening patients with signs and symptoms of chronic inflammatory prostatitis.

  12. Immunization alters body odor.

    PubMed

    Kimball, Bruce A; Opiekun, Maryanne; Yamazaki, Kunio; Beauchamp, Gary K

    2014-04-10

    Infections have been shown to alter body odor. Because immune activation accompanies both infection and immunization, we tested the hypothesis that classical immunization might similarly result in the alteration of body odors detectable by trained biosensor mice. Using a Y-maze, we trained biosensor mice to distinguish between urine odors from rabies-vaccinated (RV) and unvaccinated control mice. RV-trained mice generalized this training to mice immunized with the equine West Nile virus (WNV) vaccine compared with urine of corresponding controls. These results suggest that there are similarities between body odors of mice immunized with these two vaccines. This conclusion was reinforced when mice could not be trained to directly discriminate between urine odors of RV- versus WNV-treated mice. Next, we trained biosensor mice to discriminate the urine odors of mice treated with lipopolysaccharide (LPS; a general elicitor of innate immunological responses) from the urine of control mice. These LPS-trained biosensors could distinguish between the odors of LPS-treated mouse urine and RV-treated mouse urine. Finally, biosensor mice trained to distinguish between the odors of RV-treated mouse urine and control mouse urine did not generalize this training to discriminate between the odors of LPS-treated mouse urine and control mouse urine. From these experiments, we conclude that: (1) immunization alters urine odor in similar ways for RV and WNV immunizations; and (2) immune activation with LPS also alters urine odor but in ways different from those of RV and WNV. Published by Elsevier Inc.

  13. Design, fabrication and testing of a dual catalyst ammonia removal system for a urine VCD unit

    NASA Technical Reports Server (NTRS)

    Budinikas, P.

    1980-01-01

    A three-man capacity catalytic system for the recovery of water from urine was designed, constructed, and tested, it was designed to operate with feed streams containing high concentrations of urine vapor and only 5 to 7% of oxygen for the oxidation of ammonia and volatile organic vapor.It can operate either in a flow-through or a recycle mode and is capable of accepting the urine vapor produced by a vapor compression distillation evaporator. Testing consisted of short preliminary and optimization test, an endurance test of 74 hours continuous operation, and recycle tests using both air and oxygen. The system was designed for a urine processing rate of 0.86 liters/hr; however, it was tested at rates up to 1.2 liter/hr. Untreated urine evaporated by an electrically heated evaporator was used. The quality of the recovered water meets the U.S. Drinking Water Standards, with the exception of a low pH. Accumulation of solids in the urine sludge is reduced to approximately 65% of the anticipated value.

  14. Nappy pad urine samples for investigation and treatment of UTI in young children: the 'DUTY' prospective diagnostic cohort study.

    PubMed

    Butler, Christopher C; Sterne, Jonathan Ac; Lawton, Michael; O'Brien, Kathryn; Wootton, Mandy; Hood, Kerenza; Hollingworth, William; Little, Paul; Delaney, Brendan C; van der Voort, Judith; Dudley, Jan; Birnie, Kate; Pickles, Timothy; Waldron, Cherry-Ann; Downing, Harriet; Thomas-Jones, Emma; Lisles, Catherine; Rumsby, Kate; Durbaba, Stevo; Whiting, Penny; Harman, Kim; Howe, Robin; MacGowan, Alasdair; Fletcher, Margaret; Hay, Alastair D

    2016-07-01

    The added diagnostic utility of nappy pad urine samples and the proportion that are contaminated is unknown. To develop a clinical prediction rule for the diagnosis of urinary tract infection (UTI) based on sampling using the nappy pad method. Acutely unwell children <5 years presenting to 233 UK primary care sites. Logistic regression to identify independent associations of symptoms, signs, and urine dipstick test results with UTI; diagnostic utility quantified as area under the receiver operator curves (AUROC). Nappy pad rule characteristics, AUROC, and contamination, compared with findings from clean-catch samples. Nappy pad samples were obtained from 3205 children (82% aged <2 years; 48% female), culture results were available for 2277 (71.0%) and 30 (1.3%) had a UTI on culture. Female sex, smelly urine, darker urine, and the absence of nappy rash were independently associated with a UTI, with an internally-validated, coefficient model AUROC of 0.81 (0.87 for clean-catch), which increased to 0.87 (0.90 for clean-catch) with the addition of dipstick results. GPs' 'working diagnosis' had an AUROC 0.63 (95% confidence intervals [CI] = 0.53 to 0.72). A total of 12.2% of nappy pad and 1.8% of clean-catch samples were 'frankly contaminated' (risk ratio 6.66; 95% CI = 4.95 to 8.96; P<0.001). Nappy pad urine culture results, with features that can be reported by parents and dipstick tests, can be clinically useful, but are less accurate and more often contaminated compared with clean-catch urine culture. © British Journal of General Practice 2016.

  15. Evidence for false-positive results for boldenone testing of veal urine due to faecal cross-contamination during sampling.

    PubMed

    Sgoifo Rossi, C A; Arioli, F; Bassini, A; Chiesa, L M; Dell'Orto, V; Montana, M; Pompa, G

    2004-08-01

    European Directive 96/22/EC, which controls veterinary residues in animals, does not permit the presence of synthetic growth promoters in products of animal origin or in livestock. Boldenone is categorized in class A3 (growth promoters -- steroids) and is thus a banned substance. Testing of veal urine for banned substances is part of the European Union statutory programme for animals going into the food chain. In relation to this monitoring, three studies were conducted to investigate the apparent presence of the banned growth promoter boldenone in veal urine, which was suspected as being caused by interference from faecal contamination of the sample. In the first study, urine samples were collected at different times (time 0 and after 30 min) using (1) a conventional zoonotechnical apron and (2) a technique designed specifically to avoid faecal contamination ('kettle'). This resulted in samples that were, respectively, positive and negative for the presence of alpha-boldenone (alpha-BOL). In a second study, urine samples negative to alpha-BOL were collected from eight veal calves, but became positive after deliberate faecal contamination. In a third study, data obtained from the Italian RNP (Residual National Program) indicated that 18.1% of 3295 urine samples collected using the zootechnical apron were positive for alpha-BOL and 2.1% for beta-boldenone (beta-BOL), whilst of 902 samples collected using the kettle, beta-BOL was not detected in any samples and only 0.2% were positive to alpha-BOL, in concentrations lower than 2 ng ml(-1). These results further support the supposition that faecal contamination of the urine during sample collection can lead to false-positive results during boldenone analysis.

  16. Clinicians' interpretations of point of care urine culture versus laboratory culture results: analysis from the four-country POETIC trial of diagnosis of uncomplicated urinary tract infection in primary care.

    PubMed

    Hullegie, Saskia; Wootton, Mandy; Verheij, Theo J M; Thomas-Jones, Emma; Bates, Janine; Hood, Kerenza; Gal, Micaela; Francis, Nick A; Little, Paul; Moore, Michael; Llor, Carl; Pickles, Timothy; Gillespie, David; Kirby, Nigel; Brugman, Curt; Butler, Christopher C

    2017-08-01

    Urine culture at the point of care minimises delay between obtaining the sample and agar inoculation in a microbiology laboratory, and quantification and sensitivity results can be available more rapidly in primary care. To identify the degree to which clinicians' interpretations of a point-of-care-test (POCT) urine culture (Flexicult™ SSI-Urinary Kit) agrees with laboratory culture in women presenting to primary care with symptoms of uncomplicated urinary tract infections (UTI). Primary care clinicians used the Flexicult™-POCT, recorded their findings and took a photograph of the result, which was interpreted by microbiology laboratory technicians. Urine samples were additionally processed in routine care laboratories. Cross tabulations were used to identify important differences in organism identification, quantification and antibiotic susceptibility between these three sources of data. The influence of various laboratory definitions for UTI on culture were assessed. Primary care clinicians identified 202/289 urine samples (69.9%) as positive for UTI using the Flexicult™-POCT, whereas laboratory culture identified 94-190 (32.5-65.7%) as positive, depending on definition thresholds. 82.9% of samples identified positive for E. coli on laboratory culture were also considered positive for E. coli using the Flexicult™ -POCT, and susceptibilities were reasonably concordant. There were major discrepancies between laboratory staff interpretation of Flexicult™ photographs, clinicians' interpretation of the Flexicult™ test, and laboratory culture results. Flexicult™-POCT overestimated the positivity rate of urine samples for UTI when laboratory culture was used as the reference standard. However, it is unclear whether point-of-care or laboratory based urine culture provides the most valid diagnostic information. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  17. Evaluation of the results of Mycobacterium tuberculosis direct test (MTD) and Mycobacterial culture in urine samples

    PubMed Central

    Sener, Asli Gamze; Kurultay, Nukhet; Afsar, Ilhan

    2008-01-01

    Tuberculosis remains a public health problem in Turkey. Rapid detection of Mycobacterium tuberculosis plays a key role in control of infection. In this article, the Gen-Probe Amplified Mycobacterium Tuberculosis Direct Test (MTD) was evaluated for detection of M. tuberculosis in urine samples. The performance of the MTD was very good and appropriate for routine laboratory diagnosis. PMID:24031287

  18. Effect of vomeronasal organ removal from male mice on their preference for and neural Fos responses to female urinary odors.

    PubMed

    Pankevich, Diana E; Cherry, James A; Baum, Michael J

    2006-08-01

    Four experiments were conducted to determine whether vomeronasal organ (VNO) inputs in male mice mediate the rewarding properties of estrous female urinary odors. Sexually naive male mice with either an intact (VNOi) or lesioned (VNOx) VNO preferred to investigate female urine over water in Y-maze tests. Subsequently, VNOi males ran significantly more quickly and remained in nasal contact longer with estrous female urine than with male urine, whereas VNOx males investigated these odors equally. In home-cage habituation-dishabituation tests, VNOi males also investigated female urine significantly longer than did VNOx males, although both groups investigated female urine longer than other non-body odors. Finally, female urinary odors induced Fos in the nucleus accumbens core of VNOi males but not of VNOx males. Our results suggest that female urinary odors retain some incentive value in VNOx males. However, once direct nasal contact is made with female urine, VNO inputs further activate forebrain mechanisms that amplify the reward salience of this stimulus for the male mouse.

  19. An Initial Evaluation of a Comprehensive Continuing Care Intervention for Clients with Substance Use Disorders: My First Year of Recovery (MyFYR).

    PubMed

    McKay, James R; Knepper, Cheryl; Deneke, Erin; O'Reilly, Christopher; DuPont, Robert L

    2016-08-01

    Physician health programs (PHPs) generate high rates of sustained abstinence in addicted physicians, through a combination of formal treatment, self-help involvement, regular monitoring via random urine toxicology tests, and powerful incentives generated by the threat of losing one's medical license. Recently, Caron Treatment Centers developed a new continuing care intervention, "My First Year of Recovery" (MyFYR), which is modeled after PHPs but provides extended recovery support to a broader segment of those with substance use disorders. This paper presents initial outcome data from MyFYR. MyFYR features frequent outcomes monitoring via urine toxicology tests, and also includes a web-based social platform to coordinate efforts of recovery coaches, family members, and others (e.g., employers, probation officers). Participants were the first 198 clients who enrolled in MyFYR after participating in residential treatment at Caron. Substance use outcomes were determined by a combination of urine toxicology tests, client self-report, and information from family members obtained during a 12-month period following entry into MyFYR. Clients in MyFYR provided 70% of scheduled urine samples, for an average of 16.4 urine samples per client. Only 4.1% of the samples tested positive for alcohol or any drug. As determined by urine toxicology and client and family reports, 54% of the participants had some use of alcohol or drugs during the follow-up. Of these relapsed clients, 70.1% were retained or re-engaged in MyFYR, and of these, half were able to re-establish abstinence of two months duration or more, as documented by urine toxicology. These initial results are extremely promising, as they document high rates of sustained participation in urine drug test monitoring and positive outcome in clients not under the threat of losing a professional license or incarceration. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Uric acid test (image)

    MedlinePlus

    Uric acid urine test is performed to check for the amount of uric acid in urine. Urine is collected over a 24 ... for testing. The most common reason for measuring uric acid levels is in the diagnosis or treatment of ...

  1. Rapid Diagnosis of Tuberculosis from Analysis of Urine Volatile Organic Compounds

    PubMed Central

    Lim, Sung H.; Martino, Raymond; Anikst, Victoria; Xu, Zeyu; Mix, Samantha; Benjamin, Robert; Schub, Herbert; Eiden, Michael; Rhodes, Paul A.; Banaei, Niaz

    2017-01-01

    The World Health Organization has called for simple, sensitive, and non-sputum diagnostics for tuberculosis. We report development of a urine tuberculosis test using a colorimetric sensor array (CSA). The sensor comprised of 73 different indicators captures high-dimensional, spatiotemporal signatures of volatile chemicals emitted by human urine samples. The sensor responses to 63 urine samples collected from 22 tuberculosis cases and 41 symptomatic controls were measured under five different urine test conditions. Basified testing condition yielded the best accuracy with 85.5% sensitivity and 79.5% specificity. The CSA urine assay offers desired features needed for tuberculosis diagnosis in endemic settings. PMID:29057329

  2. Performance of the dipstick screening test as a predictor of negative urine culture.

    PubMed

    Marques, Alexandre Gimenes; Doi, André Mario; Pasternak, Jacyr; Damascena, Márcio Dos Santos; França, Carolina Nunes; Martino, Marinês Dalla Valle

    2017-01-01

    To investigate whether the urine dipstick screening test can be used to predict urine culture results. A retrospective study conducted between January and December 2014 based on data from 8,587 patients with a medical order for urine dipstick test, urine sediment analysis and urine culture. Sensitivity, specificity, positive and negative predictive values were determined and ROC curve analysis was performed. The percentage of positive cultures was 17.5%. Nitrite had 28% sensitivity and 99% specificity, with positive and negative predictive values of 89% and 87%, respectively. Leukocyte esterase had 79% sensitivity and 84% specificity, with positive and negative predictive values of 51% and 95%, respectively. The combination of positive nitrite or positive leukocyte esterase tests had 85% sensitivity and 84% specificity, with positive and negative predictive values of 53% and 96%, respectively. Positive urinary sediment (more than ten leukocytes per microliter) had 92% sensitivity and 71% specificity, with positive and negative predictive values of 40% and 98%, respectively. The combination of nitrite positive test and positive urinary sediment had 82% sensitivity and 99% specificity, with positive and negative predictive values of 91% and 98%, respectively. The combination of nitrite or leukocyte esterase positive tests and positive urinary sediment had the highest sensitivity (94%) and specificity (84%), with positive and negative predictive values of 58% and 99%, respectively. Based on ROC curve analysis, the best indicator of positive urine culture was the combination of positives leukocyte esterase or nitrite tests and positive urinary sediment, followed by positives leukocyte and nitrite tests, positive urinary sediment alone, positive leukocyte esterase test alone, positive nitrite test alone and finally association of positives nitrite and urinary sediment (AUC: 0.845, 0.844, 0.817, 0.814, 0.635 and 0.626, respectively). A negative urine culture can be predicted by negative dipstick test results. Therefore, this test may be a reliable predictor of negative urine culture. Verificar se a triagem de urina por fitas reativas é capaz de predizer a cultura de urina. Métodos Estudo retrospectivo realizado entre janeiro e dezembro de 2014 com 8.587 pacientes, com solicitação médica de triagem de urina (fita), sedimento urinário e cultura de urina. sensibilidade, especificidade, valor preditivo positivo, valor preditivo negativo e curva ROC. Foram positivas 17,5% das culturas. O nitrito apresentou sensibilidade de 28% e especificidade de 99%. O valor preditivo positivo foi de 89% e o valor preditivo negativo de 87%. Esterase apresentou sensibilidade de 79% e especificidade de 84%. Valor preditivo positivo e valor preditivo negativo foram de 51% e 95%, respectivamente. A combinação de nitrito ou esterase positivos apresentou sensibilidade de 85% e especificidade de 84%. Valor preditivo positivo e valor preditivo negativo foram, respectivamente, 53% e 96%. O sedimento positivo (mais de dez leucócitos por microlitro) apresentou sensibilidade de 92% e especificidade de 71%. O valor preditivo positivo foi 40% e o negativo, 98%. A combinação de nitrito e sedimento urinário positivos apresentou sensibilidade de 82% e especificidade de 99%. Os valores preditivos positivo e negativo foram 91% e 98%, respectivamente. Para o nitrito ou esterase positivos mais os leucócitos positivos, a sensibilidade foi de 94% e a especificidade de 84%. O valor preditivo positivo foi de 58% e o negativo foi de 99%. Com base na curva ROC, o melhor indicador de urocultura positiva foi a associação entre a esterase ou nitrito positivos na fita mais os leucócitos positivos no sedimento, seguido por nitrito e esterase positivos, sedimento urinário positivo isolado, esterase positiva isolada, nitrito positivo isolado e, finalmente, pela associação entre nitrito e sedimento urinário positivos (AUC: 0,845, 0,844, 0,817, 0,814, 0,635 e 0,626, respectivamente). Uma urocultura negativa pode ser prevista com resultados negativos na fita. Portanto, este teste pode ser um preditor confiável de urocultura negativa.

  3. Comparison of Four Strong Acids on the Precipitation Potential of Gypsum in Brines During Distillation of Pretreated, Augmented Urine

    NASA Technical Reports Server (NTRS)

    Muirhead, Dean

    2011-01-01

    Two batches of nominally pretreated and augmented urine were prepared with the baseline pretreatment formulation of sulfuric acid and chromium trioxide. The urine was augmented with inorganic salts and organic compounds in order to simulate a urinary ionic concentrations representing the upper 95 percentile on orbit. Three strong mineral acids: phosphoric, hydrochloric, and nitric acid, were substituted for the sulfuric acid for comparison to the baseline sulfuric acid pretreatment formulation. Three concentrations of oxidizer in the pretreatment formulation were also tested. Pretreated urine was distilled to 85% water recovery to determine the effect of each acid and its conjugate base on the precipitation of minerals during distillation. The brines were analyzed for calcium and sulfate ion, total, volatile, and fixed suspended solids. Test results verified that substitution of phosphoric, hydrochloric, or nitric acids for sulfuric acid would prevent the precipitation of gypsum up to 85% recovery from pretreated urine representing the upper 95 percentile calcium concentration on orbit.

  4. The clinical impact of a false-positive urine cocaine screening result on a patient's pain management.

    PubMed

    Kim, James A; Ptolemy, Adam S; Melanson, Stacy E F; Janfaza, David R; Ross, Edgar L

    2015-06-01

    The urine of a patient admitted for chest and epigastric pain tested positive for cocaine using an immunoassay-based drug screening method (positive/negative cutoff concentration 150 ng/mL). Despite the patient's denial of recent cocaine use, this positive cocaine screening result in conjunction with a remote history of drug misuse impacted the patient's recommended pain therapy. Specifically, these factors prompted the clinical team to question the appropriateness of opioids and other potentially addictive therapeutics during the treatment of cancer pain from previously undetected advanced pancreatic carcinoma. After pain management and clinical pathology consultation, it was decided that the positive cocaine screening result should be confirmed by gas chromatography-mass spectrometry (GC-MS) testing. This more sensitive and specific analytical technique revealed that both cocaine and its primary metabolite benzoylecgonine were undetectable (i.e., less than the assay detection limit of 50 ng/mL), thus indicating that the positive urine screening result was falsely positive. With this confirmation, the pain management service team was reassured in offering intrathecal pump (ITP) therapy for pain control. ITP implantation was well tolerated, and the patient eventually achieved excellent pain relief. However, ITP therapy most likely would not have been utilized without the GC-MS confirmation testing unless alternative options failed and extensive vigilant monitoring was initiated. As exemplified in this case, confirmatory drug testing should be performed on specimens with unexpected immunoassay-based drug screening results. To our knowledge, this is the first report of a false-positive urine cocaine screening result and its impact on patient management. Wiley Periodicals, Inc.

  5. Impaired insight in cocaine addiction: laboratory evidence and effects on cocaine-seeking behaviour

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moeller, S.J.; Moeller, S.J.; Maloney, T.

    Neuropsychiatric disorders are often characterized by impaired insight into behaviour. Such an insight deficit has been suggested, but never directly tested, in drug addiction. Here we tested for the first time this impaired insight hypothesis in drug addiction, and examined its potential association with drug-seeking behaviour. We also tested potential modulation of these effects by cocaine urine status, an individual difference known to impact underlying cognitive functions and prognosis. Sixteen cocaine addicted individuals testing positive for cocaine in urine, 26 cocaine addicted individuals testing negative for cocaine in urine, and 23 healthy controls completed a probabilistic choice task that assessedmore » objective preference for viewing four types of pictures (pleasant, unpleasant, neutral and cocaine). This choice task concluded by asking subjects to report their most selected picture type; correspondence between subjects self-reports with their objective choice behaviour provided our index of behavioural insight. Results showed that the urine positive cocaine subjects exhibited impaired insight into their own choice behaviour compared with healthy controls; this same study group also selected the most cocaine pictures (and fewest pleasant pictures) for viewing. Importantly, however, it was the urine negative cocaine subjects whose behaviour was most influenced by insight, such that impaired insight in this subgroup only was associated with higher cocaine-related choice on the task and more severe actual cocaine use. These findings suggest that interventions to enhance insight may decrease drug-seeking behaviour, especially in urine negative cocaine subjects, potentially to improve their longer-term clinical outcomes.« less

  6. Cortisol - urine

    MedlinePlus

    ... page: //medlineplus.gov/ency/article/003703.htm Cortisol urine test To use the sharing features on this page, please enable JavaScript. The cortisol urine test measures the level of cortisol in the ...

  7. RBC urine test

    MedlinePlus

    ... measurement for a result of this test. Normal value ranges may vary slightly among different laboratories. Some labs use different measurements or test different samples. Talk to your provider ...

  8. Diagnostic Value of Leukocyte Esterase Test Strip Reagents for Rapid Clinical Diagnosis of Spontaneous Bacterial Peritonitis in Patients Admitted to Hospital Emergency Departments in Iran.

    PubMed

    Hashemian, Amir Masoud; Ahmadi, Koorosh; Zamani Moghaddam, Hamid; Zakeri, Hosein; Davoodi Navakh, Seyed Akbar; Sharifi, Mohammad Davood; Bahrami, Abdollah

    2015-10-01

    Spontaneous bacterial peritonitis (SBP) is a common and important clinical problem and is life-threatening in decompensated liver disease. Ascites fluid test by leukocyte esterase test strip has been recently proposed as an effective and rapid method to diagnose SBP in patients with cirrhosis. This study aimed to evaluate sensitivity and specificity of leukocyte esterase test strip in the diagnosis of SBP. The population of this research was all patients with cirrhosis and ascites admitted to the emergency room at Imam Reza (AS) hospital, Mashhad. A written consent was taken for inclusion in the study. 50 mL ascites sample was taken from all patients for use in a urine test strip (LER) (Urine Test Strips Convergys®Urine Matrix 11). The patient's ascites samples were evaluated for cell counting. Positive dipstick test for LER in this study considered as grade 3 +. The values of WBC > 500 cell/mm(3) or PMN > 250 cell/mm(3) considered as positive result of the gold standard method for the diagnosis of SBP. In this study, 100 patients with ascites due to cirrhosis, with an average age of 38.9 ± 6.54 years were evaluated. Twenty cases had positive results, of whom 17 cases were also detected based on the standard diagnostic criteria and other three cases were healthy individuals. Thus, sensitivity, specificity, positive and negative predictive values, and accuracy of the method were 95%, 96.3%, 85%, 97.5% and 95%, respectively. The use of leukocyte esterase urine dipstick test can be a quick and easy method in early diagnosis of SBP to start the treatment until preparation of SBP-cell count results.

  9. Epidemiology of Schistosomiasis and Usefulness of Indirect Diagnostic Tests in School-Age Children in Cubal, Central Angola

    PubMed Central

    Bocanegra, Cristina; Gallego, Sara; Mendioroz, Jacobo; Moreno, Milagros; Sulleiro, Elena; Salvador, Fernando; Sikaleta, Nicolau; Nindia, Arlette; Tchipita, Daniel; Joromba, Morais; Kavaya, Sebastiao; Sánchez Montalvá, Adrián; López, Teresa; Molina, Israel

    2015-01-01

    Introduction Schistosomiasis remains a public health major problem and little is known in many areas, mainly in Sub-Saharan Africa Objectives To assess the burden and risk factors of schistosomiasis and intestinal parasitic helminthes in the children of Cubal, Angola, and to compare different diagnostic approaches for urinary schistosomiasis under field conditions. Methods A cross-sectional study was conducted. Urine and faeces samples of school children were microscopically studied. A random sample of children was obtained from an alphabetically arranged list of children, taking one of two children. Urine dipstick, colorimetric test and macrohaematuria were considered as indirect diagnostic methods and compared to direct urine examination. Possible risk factors for the infection were sex, age, distance to the river and previous treatment with praziquantel; the assessment was performed using Chi-square test. Results A total of 785 (61.18%) children showed S. haematobium eggs in urine; children living within 500 meters from the river had a higher odds for infection: Odds ratio 1.97 (1.45–2.7 CI 95%); urine dipstick showed sensitivity of 96% and specificity of 61.3%, with a positive predictive value; colorimetric test showed sensitivity of 52.5%, specificity of 74.6% and a positive predictive value of 77%. Proteinuria was present in 653 (51.1%) children, being more frequent in children with S. haematobium in urine (75.2%); 32 of 191 stool samples (16%) showed the presence of other intestinal parasites and 8 (4%) for S. haematobium. Conclusions Prevalence of urinary schistosomiasis in our study area is much higher than the national average, considering it as a high-risk community. Proximity to a source of water was a risk factor for the infection. Indirect tests, as urine dipstick and colorimetric test, were useful tools for diagnosis, due to ease of use and low cost. Proteinuria was a common finding, probably showing an early structural damage due to schistosomiasis in this group of children. PMID:26474169

  10. Odor Control Test Report of the Urine Containment Bag (UCB) for Orion Utilization

    NASA Technical Reports Server (NTRS)

    Casper, Stephanie; Williams, Nichole M. M.

    2010-01-01

    The purpose of this report is to summarize the conclusions for the odor control test of the Urine Containment Bag (UCB), P/N SDD46107234-306 in an environment simulating a space craft capsule. JSC 65891, Odor Control Test Plan of the Urine Containment Bag (UCB) for Orion Utilization, documents the test plan. The details of the test set-up and data reduction are detailed in the WSTF test report for this test WSTF #10-44500, Odor Control Test Plan of the Urine Containment Bag (UCB) for Orion Utilization,. This document outlines the project conclusions and forward plans with regard to trash containment for Constellation.

  11. Analytical performance, agreement and user-friendliness of six point-of-care testing urine analysers for urinary tract infection in general practice

    PubMed Central

    Schot, Marjolein J C; van Delft, Sanne; Kooijman-Buiting, Antoinette M J; de Wit, Niek J; Hopstaken, Rogier M

    2015-01-01

    Objective Various point-of-care testing (POCT) urine analysers are commercially available for routine urine analysis in general practice. The present study compares analytical performance, agreement and user-friendliness of six different POCT urine analysers for diagnosing urinary tract infection in general practice. Setting All testing procedures were performed at a diagnostic centre for primary care in the Netherlands. Urine samples were collected at four general practices. Primary and secondary outcome measures Analytical performance and agreement of the POCT analysers regarding nitrite, leucocytes and erythrocytes, with the laboratory reference standard, was the primary outcome measure, and analysed by calculating sensitivity, specificity, positive and negative predictive value, and Cohen's κ coefficient for agreement. Secondary outcome measures were the user-friendliness of the POCT analysers, in addition to other characteristics of the analysers. Results The following six POCT analysers were evaluated: Uryxxon Relax (Macherey Nagel), Urisys 1100 (Roche), Clinitek Status (Siemens), Aution 11 (Menarini), Aution Micro (Menarini) and Urilyzer (Analyticon). Analytical performance was good for all analysers. Compared with laboratory reference standards, overall agreement was good, but differed per parameter and per analyser. Concerning the nitrite test, the most important test for clinical practice, all but one showed perfect agreement with the laboratory standard. For leucocytes and erythrocytes specificity was high, but sensitivity was considerably lower. Agreement for leucocytes varied between good to very good, and for the erythrocyte test between fair and good. First-time users indicated that the analysers were easy to use. They expected higher productivity and accuracy when using these analysers in daily practice. Conclusions The overall performance and user-friendliness of all six commercially available POCT urine analysers was sufficient to justify routine use in suspected urinary tract infections in general practice. PMID:25986635

  12. Diagnostic Accuracy of Urine Protein/Creatinine Ratio Is Influenced by Urine Concentration

    PubMed Central

    Yang, Chih-Yu; Chen, Fu-An; Chen, Chun-Fan; Liu, Wen-Sheng; Shih, Chia-Jen; Ou, Shuo-Ming; Yang, Wu-Chang; Lin, Chih-Ching; Yang, An-Hang

    2015-01-01

    Background The usage of urine protein/creatinine ratio to estimate daily urine protein excretion is prevalent, but relatively little attention has been paid to the influence of urine concentration and its impact on test accuracy. We took advantage of 24-hour urine collection to examine both urine protein/creatinine ratio (UPCR) and daily urine protein excretion, with the latter as the reference standard. Specific gravity from a concomitant urinalysis of the same urine sample was used to indicate the urine concentration. Methods During 2010 to 2014, there were 540 adequately collected 24h urine samples with protein concentration, creatinine concentration, total volume, and a concomitant urinalysis of the same sample. Variables associated with an accurate UPCR estimation were determined by multivariate linear regression analysis. Receiver operating characteristic (ROC) curves were generated to determine the discriminant cut-off values of urine creatinine concentration for predicting an accurate UPCR estimation in either dilute or concentrated urine samples. Results Our findings indicated that for dilute urine, as indicated by a low urine specific gravity, UPCR is more likely to overestimate the actual daily urine protein excretion. On the contrary, UPCR of concentrated urine is more likely to result in an underestimation. By ROC curve analysis, the best cut-off value of urine creatinine concentration for predicting overestimation by UPCR of dilute urine (specific gravity ≦ 1.005) was ≦ 38.8 mg/dL, whereas the best cut-off values of urine creatinine for predicting underestimation by UPCR of thick urine were ≧ 63.6 mg/dL (specific gravity ≧ 1.015), ≧ 62.1 mg/dL (specific gravity ≧ 1.020), ≧ 61.5 mg/dL (specific gravity ≧ 1.025), respectively. We also compared distribution patterns of urine creatinine concentration of 24h urine cohort with a concurrent spot urine cohort and found that the underestimation might be more profound in single voided samples. Conclusions The UPCR in samples with low or high specific gravity is more likely to overestimate or underestimate actual daily urine protein amount, respectively, especially in a dilute urine sample with its creatinine below 38.8 mg/dL or a concentrated sample with its creatinine above 61.5 mg/dL. In particular, UPCR results should be interpreted with caution in cases that involve dilute urine samples because its overestimation may lead to an erroneous diagnosis of proteinuric renal disease or an incorrect staging of chronic kidney disease. PMID:26353117

  13. Bacteriuria amongst Pregnant Women in the Buea Health District, Cameroon: Prevalence, Predictors, Antibiotic Susceptibility Patterns and Diagnosis

    PubMed Central

    Mokube, Morike Ngoe; Atashili, Julius; Halle-Ekane, Gregory Edie; Ikomey, George M.; Ndumbe, Peter M.

    2013-01-01

    Background Bacteriuria is associated with significant maternal and foetal risks. However, its prevalence is not known in our community. Objectives This study was carried out to determine the prevalence and predictors of bacteriuria in pregnant women of the Buea Health District (BHD) as well as the antibiotic sensitivity patterns of bacterial isolates. It also sought to determine the diagnostic performance of the nitrite and leucocyte esterase tests in detecting bacteriuria in these women. Methods An observational analytic cross-sectional study was carried out amongst pregnant women attending selected antenatal care centres in Buea. We recruited 102 consenting pregnant women for the study. Demographic and clinical data were collected using structured questionnaires. Clean catch midstream urine was collected from each participant in sterile leak proof containers. Samples were examined biochemically, microscopically and by culture. Significant bacteriuria was defined as the presence of ≥108 bacteria/L of cultured urine. Identification and susceptibility of isolates was performed using API 20E and ATB UR EU (08) (BioMerieux, Marcy l'Etoile, France). Results Significant bacteriuria was found in the urine of 24 of the 102 women tested giving a bacteriuria prevalence of 23.5% in pregnant women of the BHD. Asymptomatic bacteriuria was detected in 8(7.8%) of the women. There was no statistically significant predictor of bacteriuria. Escherichia coli were the most isolated (33%) uropathogens and were 100% sensitive to cefixime, cefoxitin and cephalothin. The nitrite and leucocyte esterase tests for determining bacteriuria had sensitivities of 8%, 20.8% and specificities of 98.7% and 80.8% respectively. Conclusion Bacteriuria is frequent in pregnant women in the BHD suggesting the need for routine screening by urine culture. Empiric treatment with cefixime should be instituted until results of urine culture and sensitivity are available. Nitrite and leucocyte esterase tests were not sensitive enough to replace urine culture as screening tests. PMID:23976983

  14. Lack of clinical utility of urine gram stain for suspected urinary tract infection in pediatric patients.

    PubMed

    Cantey, Joseph B; Gaviria-Agudelo, Claudia; McElvania TeKippe, Erin; Doern, Christopher D

    2015-04-01

    Urinary tract infection (UTI) is one of the most common infections in children. Urine culture remains the gold standard for diagnosis, but the utility of urine Gram stain relative to urinalysis (UA) is unclear. We reviewed 312 pediatric patients with suspected UTI who had urine culture, UA, and urine Gram stain performed from a single urine specimen. UA was considered positive if ≥10 leukocytes per oil immersion field were seen or if either nitrates or leukocyte esterase testing was positive. Urine Gram stain was considered positive if any organisms were seen. Sensitivity, specificity, and positive and negative predictive values were calculated using urine culture as the gold standard. Thirty-seven (12%) patients had a culture-proven UTI. Compared to urine Gram stain, UA had equal sensitivity (97.3% versus 97.5%) and higher specificity (85% versus 74%). Empirical therapy was prescribed before the Gram stain result was known in 40 (49%) patients and after in 42 (51%) patients. The antibiotics chosen did not differ between the two groups (P=0.81), nor did they differ for patients with Gram-negative rods on urine Gram stain compared to those with Gram-positive cocci (P=0.67). From these data, we conclude that UA has excellent negative predictive value that is not enhanced by urine Gram stain and that antibiotic selection did not vary based on the urine Gram stain result. In conclusion, the clinical utility of urine Gram stain does not warrant the time or cost it requires. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  15. Lack of Clinical Utility of Urine Gram Stain for Suspected Urinary Tract Infection in Pediatric Patients

    PubMed Central

    Gaviria-Agudelo, Claudia; McElvania TeKippe, Erin; Doern, Christopher D.

    2015-01-01

    Urinary tract infection (UTI) is one of the most common infections in children. Urine culture remains the gold standard for diagnosis, but the utility of urine Gram stain relative to urinalysis (UA) is unclear. We reviewed 312 pediatric patients with suspected UTI who had urine culture, UA, and urine Gram stain performed from a single urine specimen. UA was considered positive if ≥10 leukocytes per oil immersion field were seen or if either nitrates or leukocyte esterase testing was positive. Urine Gram stain was considered positive if any organisms were seen. Sensitivity, specificity, and positive and negative predictive values were calculated using urine culture as the gold standard. Thirty-seven (12%) patients had a culture-proven UTI. Compared to urine Gram stain, UA had equal sensitivity (97.3% versus 97.5%) and higher specificity (85% versus 74%). Empirical therapy was prescribed before the Gram stain result was known in 40 (49%) patients and after in 42 (51%) patients. The antibiotics chosen did not differ between the two groups (P = 0.81), nor did they differ for patients with Gram-negative rods on urine Gram stain compared to those with Gram-positive cocci (P = 0.67). From these data, we conclude that UA has excellent negative predictive value that is not enhanced by urine Gram stain and that antibiotic selection did not vary based on the urine Gram stain result. In conclusion, the clinical utility of urine Gram stain does not warrant the time or cost it requires. PMID:25653411

  16. Protocol for accuracy of point of care (POC) or in-office urine drug testing (immunoassay) in chronic pain patients: a prospective analysis of immunoassay and liquid chromatography tandem mass spectometry (LC/MS/MS).

    PubMed

    Manchikanti, Laxmaiah; Malla, Yogesh; Wargo, Bradley W; Cash, Kimberly A; Pampati, Vidyasagar; Damron, Kim S; McManus, Carla D; Brandon, Doris E

    2010-01-01

    Therapeutic use, overuse, abuse, and diversion of controlled substances in managing chronic non-cancer pain continues to be an issue for physicians and patients. It has been stated that physicians, along with the public and federal, state, and local government; professional associations; and pharmaceutical companies all share responsibility for preventing abuse of controlled prescription drugs. The challenge is to eliminate or significantly curtail abuse of controlled prescription drugs while still assuring the proper treatment of those patients. A number of techniques, instruments, and tools have been described to monitor controlled substance use and abuse. Thus, multiple techniques and tools available for adherence monitoring include urine drug testing in conjunction with prescription monitoring programs and other screening tests. However, urine drug testing is associated with multiple methodological flaws. Multiple authors have provided conflicting results in relation to diagnostic accuracy with differing opinions about how to monitor adherence in a non-systematic fashion. Thus far, there have not been any studies systematically assessing the diagnostic accuracy of immunoassay with laboratory testing. A diagnostic accuracy study of urine drug testing. An interventional pain management practice, a specialty referral center, a private practice setting in the United States. To compare the information obtained by point of care (POC) or in-office urine drug testing (index test) to the information found when all drugs and analytes are tested by liquid chromatography tandem mass spectroscopy (LC/MS/MS) reference test in the same urine sample. The study is designed to include 1,000 patients with chronic pain receiving controlled substances. The primary outcome measure is the diagnostic accuracy. Patients will be tested for various controlled substances, including opioids, benzodiazepines, and illicit drugs. The diagnostic accuracy study is performed utilizing the Standards for Reporting of Diagnostic Accuracy Studies (STARD) initiative which established reporting guidelines for diagnostic accuracy studies to improve the quality of reporting. The prototypical flow diagram of diagnostic accuracy study as described by STARD will be utilized. Results of diagnostic accuracy and correlation of clinical factors in relation to threshold levels, prevalence of abuse, false-positives, false-negatives, influence of other drugs, and demographic characteristics will be calculated. The limitations include lack of availability of POC testing with lower cutoff levels. This article presents a protocol for a diagnostic accuracy study of urine drug testing. The protocol also will permit correlation of various clinical factors in relation to threshold levels, prevalence of abuse, false-positives, false-negatives, influence of other drugs, and demographic characteristics. NCT 01052155.

  17. Urine and oral fluid drug testing in support of pain management.

    PubMed

    Kwong, Tai C; Magnani, Barbarajean; Moore, Christine

    2017-09-01

    In recent years, the abuse of opioid drugs has resulted in greater prevalence of addiction, overdose, and deaths attributable to opioid abuse. The epidemic of opioid abuse has prompted professional and government agencies to issue practice guidelines for prescribing opioids to manage chronic pain. An important tool available to providers is the drug test for use in the initial assessment of patients for possible opioid therapy, subsequent monitoring of compliance, and documentation of suspected aberrant drug behaviors. This review discusses the issues that most affect the clinical utility of drug testing in chronic pain management with opioid therapy. It focuses on the two most commonly used specimen matrices in drug testing: urine and oral fluid. The advantages and disadvantages of urine and oral fluid in the entire testing process, from specimen collection and analytical methodologies to result interpretation are reviewed. The analytical sensitivity and specificity limitations of immunoassays used for testing are examined in detail to draw attention to how these shortcomings can affect result interpretation and influence clinical decision-making in pain management. The need for specific identification and quantitative measurement of the drugs and metabolites present to investigate suspected aberrant drug behavior or unexpected positive results is analyzed. Also presented are recent developments in optimization of test menus and testing strategies, such as the modification of the standard screen and reflexed-confirmation testing model by eliminating some of the initial immunoassay-based tests and proceeding directly to definitive testing by mass spectrometry assays.

  18. Paper-Plastic Hybrid Microfluidic Device for Smartphone-Based Colorimetric Analysis of Urine.

    PubMed

    Jalal, Uddin M; Jin, Gyeong Jun; Shim, Joon S

    2017-12-19

    In this work, a disposable paper-plastic hybrid microfluidic lab-on-a-chip (LOC) has been developed and successfully applied for the colorimetric measurement of urine by the smartphone-based optical platform using a "UrineAnalysis" Android app. The developed device was cost-effectively implemented as a stand-alone hybrid LOC by incorporating the paper-based conventional reagent test strip inside the plastic-based LOC microchannel. The LOC device quantitatively investigated the small volume (40 μL) of urine analytes for the colorimetric reaction of glucose, protein, pH, and red blood cell (RBC) in integration with the finger-actuating micropump. On the basis of our experiments, the conventional urine strip showed large deviation as the reaction time goes by, because dipping the strip sensor in a bottle of urine could not control the reaction volume. By integrating the strip sensor in the LOC device for urine analysis, our device significantly improves the time-dependent inconstancy of the conventional dipstick-based urine strip, and the smartphone app used for image analysis enhances the visual assessment of the test strip, which is a major user concern for the colorimetric analysis in point-of-care (POC) applications. As a result, the user-friendly LOC, which is successfully implemented in a disposable format with the smartphone-based optical platform, may be applicable as an effective tool for rapid and qualitative POC urinalysis.

  19. Molecular epidemiology and clinical implications of metallo-β-lactamase-producing Pseudomonas aeruginosa isolated from urine.

    PubMed

    Sako, Shinichi; Kariyama, Reiko; Mitsuhata, Ritsuko; Yamamoto, Masumi; Wada, Koichiro; Ishii, Ayano; Uehara, Shinya; Kokeguchi, Susumu; Kusano, Nobuchika; Kumon, Hiromi

    2014-01-01

    We conducted a study on molecular epidemiology and clinical implications of metallo-beta-lactamase (MBL)-producing Pseudomonas aeruginosa isolated from urine. Over a 10-year period from 2001 through 2010, a total of 92 MBL-producing P. aeruginosa urine isolates were collected from patients (one isolate per patient) who were admitted to 5 hospitals in Okayama Prefecture, Japan. When cross-infection was suspected in the hospital, pulsed-field gel electrophoresis was performed. In the resulting dendrogram of 79 MBL-producing P. aeruginosa urine isolates, no identical isolates and 7 pairs of isolates with >80% similarity were found. The biofilm-forming capabilities of 92 MBL-producing P. aeruginosa urine isolates were significantly greater than those of 92 non-MBL-producing urine isolates in a medium of modified artificial urine. The imipenem resistance transferred in 16 of 18 isolates tested, and these frequencies were in the range of 10⁻³ to 10⁻⁹. All of 18 isolates tested belonged to internationally spread sequence type 235 and had 3 gene cassettes of antimicrobial resistance genes in the class 1 integron. The strong biofilm-forming capabilities of MBL-producing P. aeruginosa urine isolates could be seriously implicated in nosocomial infections. To prevent spread of the organism and transferable genes, effective strategies to inhibit biofilm formation in medical settings are needed.

  20. Urine podocyte mRNAs mark disease activity in IgA nephropathy

    PubMed Central

    Fukuda, Akihiro; Sato, Yuji; Iwakiri, Takashi; Komatsu, Hiroyuki; Kikuchi, Masao; Kitamura, Kazuo; Wiggins, Roger C.; Fujimoto, Shouichi

    2015-01-01

    Background Podocyte depletion is a major mechanism driving glomerulosclerosis. We and others have previously projected from model systems that podocyte-specific mRNAs in the urine pellet might serve as glomerular disease markers. We evaluated IgA nephropathy (IgAN) to test this concept. Methods From 2009 to 2013, early morning voided urine samples and kidney biopsies from IgAN patients (n = 67) were evaluated in comparison with urine samples from healthy age-matched volunteers (n = 28). Urine podocyte (podocin) mRNA expressed in relation to either urine creatinine concentration or a kidney tubular marker (aquaporin 2) was tested as markers. Results Urine podocyte mRNAs were correlated with the severity of active glomerular lesions (segmental glomerulosclerosis and acute extracapillary proliferation), but not with non-glomerular lesions (tubular atrophy/interstitial fibrosis) or with clinical parameters of kidney injury (serum creatinine and estimated glomerular filtration rate), or with degree of accumulated podocyte loss at the time of biopsy. In contrast, proteinuria correlated with all histological and clinical markers. Glomerular tuft podocyte nuclear density (a measure of cumulative podocyte loss) correlated with tubular atrophy/interstitial fibrosis, estimated-glomerular filtration rate and proteinuria, but not with urine podocyte markers. In a subset of the IgA cohort (n = 19, median follow-up period = 37 months), urine podocyte mRNAs were significantly decreased after treatment, in contrast to proteinuria which was not significantly changed. Conclusions Urine podocyte mRNAs reflect active glomerular injury at a given point in time, and therefore provide both different and additional clinical information that can complement proteinuria in the IgAN decision-making paradigm. PMID:25956757

  1. Creatine transporter deficiency: prevalence among patients with mental retardation and pitfalls in metabolite screening.

    PubMed

    Arias, Angela; Corbella, Marc; Fons, Carmen; Sempere, Angela; García-Villoria, Judit; Ormazabal, Aida; Poo, Pilar; Pineda, Mercé; Vilaseca, María Antonia; Campistol, Jaume; Briones, Paz; Pàmpols, Teresa; Salomons, Gajja S; Ribes, Antonia; Artuch, Rafael

    2007-11-01

    To report the prevalence of creatine transporter deficiency in males with mental retardation and to study whether a protein-rich food intake might be a potential diagnostic pitfall. We determined creatine/creatinine ratio in urine samples from 1600 unrelated male patients with mental retardation and/or autism. Urine creatine was analyzed by HPLC-MS/MS. Thirty-three of 1600 cases showed increased urine creatine/creatinine ratio. Four out of these thirty-three cases were definitively diagnosed with creatine transporter deficiency, while the other 29 were false positive results. Significantly higher values were observed for urine Cr/Crn ratio in healthy volunteers after a meal based on beef or oily fish as compared to eggs, pasta or salad (Wilcoxon test: p<0.005). False positive results may be observed in biochemical screening for creatine transporter deficiency, and they may be due to intake of meals rich in creatine prior to urine samples analysis.

  2. The Effect of Weight Reduction on the Blood and Urine Measurements of College Wrestlers.

    ERIC Educational Resources Information Center

    Segurson, Jack

    It has been suggested that the weight reduction practices of wrestlers results in kidney and liver problems. To observe the effect of wrestlers' weight reduction, diagnostic tests for kidney and liver problems were done on the blood and urine samples of 22 college wrestlers over the course of a wrestling season. Results obtained after reduction to…

  3. Uric acid - urine

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/003616.htm Uric acid urine test To use the sharing features on this page, please enable JavaScript. The uric acid urine test measures the level of uric acid ...

  4. 75 FR 39023 - Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-07

    ... Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for Federal... Drug Testing Programs (Mandatory Guidelines). The Mandatory Guidelines were first published in the... of Laboratories Engaged in Urine Drug Testing for Federal Agencies,'' sets strict standards that...

  5. 75 FR 27348 - Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-14

    ... Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for Federal... Drug Testing Programs (Mandatory Guidelines). The Mandatory Guidelines were first published in the... of Laboratories Engaged in Urine Drug Testing for Federal Agencies,'' sets strict standards that...

  6. 75 FR 9229 - Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-01

    ... Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for Federal... Drug Testing Programs (Mandatory Guidelines). The Mandatory Guidelines were first published in the... of Laboratories Engaged in Urine Drug Testing for Federal Agencies,'' sets strict standards that...

  7. 75 FR 5088 - Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-01

    ... Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for Federal... Drug Testing Programs (Mandatory Guidelines). The Mandatory Guidelines were first published in the... of Laboratories Engaged in Urine Drug Testing for Federal Agencies,'' sets strict standards that...

  8. 75 FR 154 - Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-04

    ... Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for Federal... Drug Testing Programs (Mandatory Guidelines). The Mandatory Guidelines were first published in the... of Laboratories Engaged in Urine Drug Testing for Federal Agencies,'' sets strict standards that...

  9. 75 FR 45128 - Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-02

    ... Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for Federal... Drug Testing Programs (Mandatory Guidelines). The Mandatory Guidelines were first published in the..., ``Certification of Laboratories Engaged in Urine Drug Testing for Federal Agencies,'' sets strict standards that...

  10. 75 FR 32950 - Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-10

    ... Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for Federal... Drug Testing Programs (Mandatory Guidelines). The Mandatory Guidelines were first published in the... of Laboratories Engaged in Urine Drug Testing for Federal Agencies,'' sets strict standards that...

  11. 75 FR 55795 - Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-14

    ... Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for Federal... Drug Testing Programs (Mandatory Guidelines). The Mandatory Guidelines were first published in the... of Laboratories Engaged in Urine Drug Testing for Federal Agencies,'' sets strict standards that...

  12. Overcoming barriers to HIV testing: preferences for new strategies among clients of a needle exchange, a sexually transmitted disease clinic, and sex venues for men who have sex with men.

    PubMed

    Spielberg, Freya; Branson, Bernard M; Goldbaum, Gary M; Lockhart, David; Kurth, Ann; Celum, Connie L; Rossini, Anthony; Critchlow, Cathy W; Wood, Robert W

    2003-03-01

    To determine strategies to overcome barriers to HIV testing among persons at risk. We developed a survey that elicited testing motivators, barriers, and preferences for new strategies among 460 participants at a needle exchange, three sex venues for men who have sex with men, and a sexually transmitted disease clinic. Barriers to testing included factors influenced by individual concern (fear and discrimination); by programs, policies, and laws (named reporting and inability to afford treatment); and by counseling and testing strategies (dislike of counseling, anxiety waiting for results, and venipuncture). The largest proportions of participants preferred rapid testing strategies, including clinic-based testing (27%) and home self-testing (20%); roughly equal proportions preferred oral fluid testing (18%), urine testing (17%), and standard blood testing (17%). One percent preferred home specimen collection. Participants who had never tested before were significantly more likely to prefer home self-testing compared with other strategies. Blacks were significantly more likely to prefer urine testing. Strategies for improving acceptance of HIV counseling and testing include information about access to anonymous testing and early treatment. Expanding options for rapid testing, urine testing, and home self-testing; providing alternatives to venipuncture; making pretest counseling optional; and allowing telephone results disclosure may encourage more persons to learn their HIV status.

  13. Effect of urine creatinine level during pregnancy on dipstick test.

    PubMed

    Baba, Yosuke; Furuta, Itsuko; Zhai, Tianyue; Ohkuchi, Akihide; Yamada, Takahiro; Takahashi, Kayo; Matsubara, Shigeki; Minakami, Hisanori

    2017-06-01

    Dipstick results for proteinuria are affected by urine concentration, and thus urine creatinine concentration ([Cr]). This study was performed to determine whether spot urine [Cr] changes significantly during pregnancy, leading to a significantly different false-negative rate (FNR) on dipstick test between trimester. The [Cr] and protein concentrations ([P]) were analyzed in 631 spot urine samples with negative/equivocal dipstick from 425 pregnant women. False-negative dipstick was defined as [P] : [Cr] ratio (P/Cr) > 0.27 mg/mg. Median [Cr] was 117 mg/dL (range, 6.5-326 mg/dL), 72 mg/dL (range, 4.3-477 mg/dL), and 73 mg/dL (range, 8.4-396 mg/dL) in the first (n = 96), second (n = 344), and third (n = 191) trimester urine samples, respectively (P = 0.000, Kruskal-Wallis). Both [P] and P/Cr increased significantly with advancing gestation. FNR 9.4% (18/191) in the third trimester was significantly higher than that of 0.0% (0/96) in the second trimester and that of 0.5% (2/344) in the third trimester. In the 20 urine samples with false-negative dipstick, median [Cr] was 47.0 mg/dL (range, 11.0-358 mg/dL) and the proportion of samples with dilute urine, that is, [Cr] <47 mg/dL, was significantly higher than in the remaining 611 urine samples (50%, 10/20 vs 28%, 174/611, respectively, P = 0.046). Urine samples in the second and third trimesters were more likely to be diluted compared with the first trimester. This was associated with high FNR in third trimester urine samples. © 2017 Japan Society of Obstetrics and Gynecology.

  14. Impaired Urine Dilution Capability in HIV Stable Patients

    PubMed Central

    Belloso, Waldo H.; de Paz Sierra, Mariana; Navarro, Matilde; Sanchez, Marisa L.; Perelsztein, Ariel G.; Musso, Carlos G.

    2014-01-01

    Renal disease is a well-recognized complication among patients with HIV infection. Viral infection itself and the use of some antiretroviral drugs contribute to this condition. The thick ascending limb of Henle's loop (TALH) is the tubule segment where free water clearance is generated, determining along with glomerular filtration rate the kidney's ability to dilute urine. Objective. We analyzed the function of the proximal tubule and TALH in patients with HIV infection receiving or not tenofovir-containing antiretroviral treatment in comparison with healthy seronegative controls, by applying a tubular physiological test, hyposaline infusion test (Chaimowitz' test). Material & Methods. Chaimowitz' test was performed on 20 HIV positive volunteers who had normal renal functional parameters. The control group included 10 healthy volunteers. Results. After the test, both HIV groups had a significant reduction of serum sodium and osmolarity compared with the control group. Free water clearance was lower and urine osmolarity was higher in both HIV+ groups. Proximal tubular function was normal in both studied groups. Conclusion. The present study documented that proximal tubule sodium reabsorption was preserved while free water clearance and maximal urine dilution capability were reduced in stable HIV patients treated or not with tenofovir. PMID:24800076

  15. Urinalysis and associated laboratory procedures.

    PubMed

    Brobst, D

    1989-09-01

    Macroscopic examination of urine is an integral part of urinalysis, and blood and bile pigments are a common cause of abnormal coloration. Urine SG is a convenient index of urine concentration and should be correlated with the patient's hydration status to determine the ability of the kidneys to concentrate and dilute urine. The pH of urine of dogs and cats normally is dietary dependent, but alkaline urine may suggest that the urinary tract is infected with a urea splitting organism. The dipstick test for proteinuria is convenient but less reliable than the sulfosalicylic acid method. The dipstick test for blood should not be used as a substitute for microscopic examination of urine but is of value in detecting hemoglobinuria and myoglobinuria, when red cells may be absent in the sediment. The finding of glucose, ketones, and bilirubin in urine, when interpreted properly, may indicate the presence of disease processes not associated with the urogenital tract. Microscopic examination of urine sediment must be interpreted in combination with the physical and chemical composition of urine, but excessive numbers of cells, casts, crystals, and bacteria may provide evidence of disease. The absence of these structures in the sediment, however, does not eliminate the possibility of disease. The ability of the kidneys to concentrate urine is dependent on normal kidney function and the production and release of ADH. A urine SG greater than 1.030 in dogs and 1.035 in cats indicates that the functions associated with concentrating urine are adequate. In the evaluation of the patient's ability to form concentrated urine, the status of hydration must be considered; this may require water deprivation tests or administration of ADH. The estimation of blood urea nitrogen concentration, with the use of test strips, may provide a convenient but not specific measure of renal function.

  16. Salt as a mitigation option for decreasing nitrogen leaching losses from grazed pastures.

    PubMed

    Ledgard, Stewart F; Welten, Brendon; Betteridge, Keith

    2015-12-01

    The main source of nitrogen (N) leaching from grazed pastures is animal urine with a high N deposition rate (i.e. per urine patch), particularly between late summer and early winter. Salt is a potential mitigation option as a diuretic to induce greater drinking-water intake, increase urination frequency, decrease urine N concentration and urine N deposition rate, and thereby potentially decrease N leaching. This hypothesis was tested in three phases: a cattle metabolism stall study to examine effects of salt supplementation rate on water consumption, urination frequency and urine N concentration; a grazing trial to assess effects of salt (150 g per heifer per day) on urination frequency; and a lysimeter study on effects of urine N rate on N leaching. Salt supplementation increased cattle water intake. Urination frequency increased by up to 69%, with a similar decrease in urine N deposition rate and no change in individual urination volume. Under field grazing, sensors showed increased urination frequency by 17%. Lysimeter studies showed a proportionally greater decrease in N leaching with decreased urine N rate. Modelling revealed that this could decrease per-hectare N leaching by 10-22%. Salt supplementation increases cattle water intake and urination frequency, resulting in a lower urine N deposition rate and proportionally greater decrease in urine N leaching. Strategic salt supplementation in autumn/early winter with feed is a practical mitigation option to decrease N leaching in grazed pastures. © 2015 Society of Chemical Industry.

  17. Urine Cultures in Hospitalized Geriatric Patients Presenting With Fever.

    PubMed

    Shimoni, Zvi; Avdiaev, Ruslan; Froom, Paul

    2017-01-01

    Urine cultures are commonly ordered in geriatric patients presenting with fever in the emergency department, but it is unclear if indiscriminate urine culture testing is warranted. We selected 708 consecutive geriatric patients with a chief complaint of fever to determine the clinical usage (changes in antibiotic therapy according to culture results) and the costs of culturing the urine that included the need for catheterization to obtain a sample for culture and complications from catheterization. We divided the patients into those with and without an extraurinary tract source for fever on admission. Urine cultures were performed in 74.9% (233/312) of the patients with a source for the fever outside the urinary tract and required urinary catheterization to obtain a sample in 36.8% (95/233) of those patients. Cultures were positive for bacteria 29.6% of the time (69/233), but did not result in the change of antibiotic treatment in any of the patients. Urine cultures were performed in 92.6% (326/352) of the patients without an extraurinary tract source for the fever, required catheterization in 49.7% (162/326) of the patients and 58.3% (190/326) of the cultures were positive for bacteria. Urine culture sensitivities changed antibiotic therapy in 24.2% (46/190) of the patients. There were no patients in either group with complications from urinary catheterization, but indwelling catheter rates increased inappropriately in both the groups. We conclude that urine culture testing is unnecessary in hospitalized geriatric patients who on admission have an extraurinary tract source for their fever, but it has clinical usage when the source for the fever on admission is unclear. Copyright © 2017 Southern Society for Clinical Investigation. Published by Elsevier Inc. All rights reserved.

  18. EMMPRIN and ADAM12 in prostate cancer: preliminary results of a prospective study.

    PubMed

    Bilgin Doğru, Elif; Dizdar, Yavuz; Akşit, Ece; Ural, Feyyaz; Şanlı, Öner; Yasasever, Vildan

    2014-11-01

    Extracellular metalloproteinase inducer (EMMPRIN) and a disintegrin and metalloproteinase (ADAM12) play a major role in cancer invasion and metastasis owing to the fact that they are directly related to the cell microenvironment and extracellular matrix (ECM) degradation. The aim of this study was to search for an answer to the question "whether the determination of EMMPRIN and ADAM12 values especially in urine may be helpful for the early diagnosis of prostate cancer without employing invasive methods" and also to check whether they may be useful for the determination of the patients with high metastasis risk. Peripheral blood and urine from 66 prostate cancer patients (40 local, 20 locally advanced, 6 metastatic) and 14 healthy controls were evaluated by enzyme-linked immunosorbent assay (ELISA) method. Serum EMMPRIN and ADAM12 values of the patients were seen to be statistically higher than the serum EMMPRIN and ADAM12 values of the healthy controls (p=0.01 and p=0.001, respectively). The urine ADAM12 levels were significantly higher in patients (p=0.013). No significant relationships were found between urine EMMPRIN values of the patients and the healthy controls (p>0.05). Positive correlation between urine EMMPRIN-urine ADAM12 tests was found in total patients group (r=0.683, p=0.001). Our preliminary results revealed that serum EMMPRIN and ADAM12 values and urine ADAM12 values may be useful markers in prostate cancer therapy. Due to the high correlation between these two tests, we are of the opinion that the use of urine ADAM12 in clinic may be sufficient and favorable together with prostate-specific antigen (PSA) for treatment.

  19. Gestational Trophoblastic Disease Diagnosis Delayed by the Hook Effect.

    PubMed

    Cormano, Julia; Mackay, Gillian; Holschneider, Christine

    2015-10-01

    A "hook effect" resulting from saturation of antibodies used in pregnancy tests can occur at human chorionic gonadotropin (hCG) levels above 500,000 milliinternational units/mL, resulting in falsely negative values. A 34-year-old woman, gravida 5 para 3, presented to the emergency department after heavy bleeding. Ultrasonogram revealed a uterine mass, urine pregnancy test result was negative, and endometrial biopsy inconclusive. The patient was discharged and presented 10 days later with recurrent bleeding. Urine pregnancy test result was again negative, but serum hCG was 581 milliinternational units/mL. Serial dilution revealed an actual hCG higher than 5 million milliinternational units/mL. She was diagnosed with gestational trophoblastic disease. Awareness of the risk of a false-negative pregnancy test result when hCG levels are extremely high may prevent delayed diagnosis of gestational trophoblastic disease.

  20. Urine Galactomannan-to-Creatinine Ratio for Detection of Invasive Aspergillosis in Patients with Hematological Malignancies.

    PubMed

    Reischies, Frederike M J; Raggam, Reinhard B; Prattes, Juergen; Krause, Robert; Eigl, Susanne; List, Agnes; Quehenberger, Franz; Strenger, Volker; Wölfler, Albert; Hoenigl, Martin

    2016-03-01

    Galactomannan (GM) testing of urine specimens may provide important advantages, compared to serum testing, such as easy noninvasive sample collection. We evaluated a total of 632 serial urine samples from 71 patients with underlying hematological malignancies and found that the urine GM/creatinine ratio, i.e., (urine GM level × 100)/urine creatinine level, which takes urine dilution into account, reliably detected invasive aspergillosis and may be a promising diagnostic tool for patients with hematological malignancies. (This study has been registered at ClinicalTrials.gov under registration no. NCT01576653.). Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  1. False-positive LSD testing in urine samples from intensive care patients.

    PubMed

    Röhrich, J; Zörntlein, S; Lotz, J; Becker, J; Kern, T; Rittner, C

    1998-09-01

    Unexpected positive results for lysergic acid diethylamide (LSD) were found in urine samples from 12 patients in an intensive care unit in a routine screening using the CEDIA DAU assay. None of these test results could be confirmed by high-performance liquid chromatography analysis, but all samples contained the mucolytic drug ambroxol. Further studies demonstrated that ambroxol exhibits a significant cross-reactivity in the CEDIA DAU LSD assay. Therefore, positive LSD results obtained with the CEDIA DAU assay have to be critically evaluated, particularly during the cold season, when infections of the respiratory tract often result in more frequent use of mucolytic medications.

  2. Blood in Urine: MedlinePlus Lab Test Information

    MedlinePlus

    ... Information → Blood in Urine URL of this page: https://medlineplus.gov/labtests/bloodinurine.html Blood in Urine ... 2017 Mar 14]; [about 4 screens]: Available from: https://labtestsonline.org/understanding/analytes/urinalysis/tab/test Lab ...

  3. Nitrites in Urine

    MedlinePlus

    ... Why do I need a nitrites in urine test? Your health care provider may have ordered a urinalysis as part ... Fever What happens during a nitrites in urine test? Your health care provider will need to collect a sample of ...

  4. Lab Test Information

    MedlinePlus

    ... Mumps Tests MPV Blood Test Mucus in Urine N Nitrites in Urine P Pap Smear Porphyrin Test ... V Vitamin D Test Vitamin E (tocopherol) Test Y Yeast Infection Test Related MedlinePlus Health Topics Laboratory ...

  5. Dipstick measurements of urine specific gravity are unreliable.

    PubMed

    de Buys Roessingh, A S; Drukker, A; Guignard, J P

    2001-08-01

    To evaluate the reliability of dipstick measurements of urine specific gravity (U-SG). Fresh urine specimens were tested for urine pH and osmolality (U-pH, U-Osm) by a pH meter and an osmometer, and for U-SG by three different methods (refractometry, automatic readout of a dipstick (Clinitek-50), and (visual) change of colour of the dipstick). The correlations between the visual U-SG dipstick measurements and U-SG determined by a refractometer and the comparison of Clinitek((R))-50 dipstick U-SG measurements with U-Osm were less than optimal, showing very wide scatter of values. Only the U-SG refractometer values and U-Osm had a good linear correlation. The tested dipstick was unreliable for the bedside determination of U-SG, even after correction for U-pH, as recommended by the manufacturer. Among the bedside determinations, only refractometry gives reliable U-SG results. Dipstick U-SG measurements should be abandoned.

  6. Polyuria and ‘watery wee’ in a toddler

    PubMed Central

    Ding, Jane; Perera, Leonie

    2012-01-01

    A 2-year-old girl presented with intermittent dysuria. Following triage in paediatric A+E, the nursing staff became concerned with the large sample of colourless urine she produced, which tested positive for leucocytes. She was described as a ‘big drinker’ to the SHO, raising concerns about diabetes insipidus. On detailed questioning it emerged that she had recently drunk a herbal tea preparation (buchu, couchgrass, marshmallow and plantain) to help ‘flush out’ her urinary system. She was advised to stop the tea. She had localised genital irritation and was discharged home with hygiene/barrier advice, pending urine culture results. She represented 2 days later with worsening dysuria and fever. Her urine was of normal colour and tested positive for leucocytes, nitrites and blood, hence she started antibiotics (urine cultures subsequently grew coliforms). Herbal use in children is not uncommon and should be considered as a cause of polyuria. PMID:23239780

  7. Evaluation of four slide test kits for the detection of human chorionic gonadotropin in urine

    PubMed Central

    Dietrich, Michael; French, J. A.

    1974-01-01

    Three “indirect-type” slide tests utilizing the principle of hemagglutination inhibition and one new “direct-type” slide test employing direct agglutination were evaluated for their sensitivity in detecting human chorionic gonadotropin (HCG) in urine. The results of positive tests in a group of woman in very early pregnancy were correlated with the “days after last menses”. In this series the direct slide test was the most accurate. A control must be used with each direct test to indicate interfering substances and when such are present a different test must be used. All tests were found to be of the relative sensitivity stated by the manufacturer. PMID:4851924

  8. Prostatectomy-based validation of combined urine and plasma test for predicting high grade prostate cancer.

    PubMed

    Albitar, Maher; Ma, Wanlong; Lund, Lars; Shahbaba, Babak; Uchio, Edward; Feddersen, Søren; Moylan, Donald; Wojno, Kirk; Shore, Neal

    2018-03-01

    Distinguishing between low- and high-grade prostate cancers (PCa) is important, but biopsy may underestimate the actual grade of cancer. We have previously shown that urine/plasma-based prostate-specific biomarkers can predict high grade PCa. Our objective was to determine the accuracy of a test using cell-free RNA levels of biomarkers in predicting prostatectomy results. This multicenter community-based prospective study was conducted using urine/blood samples collected from 306 patients. All recruited patients were treatment-naïve, without metastases, and had been biopsied, designated a Gleason Score (GS) based on biopsy, and assigned to prostatectomy prior to participation in the study. The primary outcome measure was the urine/plasma test accuracy in predicting high grade PCa on prostatectomy compared with biopsy findings. Sensitivity and specificity were calculated using standard formulas, while comparisons between groups were performed using the Wilcoxon Rank Sum, Kruskal-Wallis, Chi-Square, and Fisher's exact test. GS as assigned by standard 10-12 core biopsies was 3 + 3 in 90 (29.4%), 3 + 4 in 122 (39.8%), 4 + 3 in 50 (16.3%), and > 4 + 3 in 44 (14.4%) patients. The urine/plasma assay confirmed a previous validation and was highly accurate in predicting the presence of high-grade PCa (Gleason ≥3 + 4) with sensitivity between 88% and 95% as verified by prostatectomy findings. GS was upgraded after prostatectomy in 27% of patients and downgraded in 12% of patients. This plasma/urine biomarker test accurately predicts high grade cancer as determined by prostatectomy with a sensitivity at 92-97%, while the sensitivity of core biopsies was 78%. © 2018 Wiley Periodicals, Inc.

  9. Usefulness of Leukocyte Esterase Test Versus Rapid Strep Test for Diagnosis of Acute Strep Pharyngitis

    PubMed Central

    2015-01-01

    Objective: A study to compare the usage of throat swab testing for leukocyte esterase on a test strip(urine dip stick-multi stick) to rapid strep test for rapid diagnosis of Group A Beta hemolytic streptococci in cases of acute pharyngitis in children. Hypothesis: The testing of throat swab for leukocyte esterase on test strip currently used for urine testing may be used to detect throat infection and might be as useful as rapid strep. Methods: All patients who come with a complaint of sore throat and fever were examined clinically for erythema of pharynx, tonsils and also for any exudates. Informed consent was obtained from the parents and assent from the subjects. 3 swabs were taken from pharyngo-tonsillar region, testing for culture, rapid strep & Leukocyte Esterase. Results: Total number is 100. Cultures 9(+); for rapid strep== 84(-) and16 (+); For LE== 80(-) and 20(+) Statistics: From data configuration Rapid Strep versus LE test don’t seem to be a random (independent) assignment but extremely aligned. The Statistical results show rapid and LE show very agreeable results. Calculated Value of Chi Squared Exceeds Tabulated under 1 Degree Of Freedom (P<.0.0001) reject Null Hypothesis and Conclude Alternative Conclusions: Leukocyte esterase on throat swab is as useful as rapid strep test for rapid diagnosis of strep pharyngitis on test strip currently used for urine dip stick causing acute pharyngitis in children. PMID:27335975

  10. Long-Term Follow-up of HPV Infection Using Urine and Cervical Quantitative HPV DNA Testing

    PubMed Central

    Vorsters, Alex; Van Keer, Severien; Biesmans, Samantha; Hens, Annick; De Coster, Ilse; Goossens, Herman; Ieven, Margareta; Van Damme, Pierre

    2016-01-01

    The link between infection with high-risk human papillomavirus (hrHPV) and cervical cancer has been clearly demonstrated. Virological end-points showing the absence of persistent HPV infection are now accepted as a way of monitoring the impact of prophylactic vaccination programs and therapeutic vaccine trials. This study investigated the use of urine samples, which can be collected by self-sampling at home, instead of cervical samples for follow-up of an HPV intervention trial. Eighteen initially HPV DNA-positive women participating in an HPV therapeutic vaccine trial were monitored during a three-year follow-up period. A total of 172 urine samples and 85 cervical samples were collected. We obtained a paired urine sample for each of the 85 cervical samples by recovering urine samples from six monthly gynaecological examinations. We performed a small pilot study in which the participating women used a urine collection device at home and returned their urine sample to the laboratory by mail. All samples were analyzed using quantitative real-time HPV DNA PCR. A good association (κ value of 0.65) was found between the presence of HPV DNA in urine and a subsequent cervical sample. Comparisons of the number of HPV DNA copies in urine and paired cervical samples revealed a significant Spearman rho of 0.676. This correlation was superior in women with severe lesions. The HPV DNA results of the small pilot study based on self-collected urine samples at home are consistent with previous and subsequent urine and/or cervical results. We demonstrated that urine sampling may be a valid alternative to cervical samples for the follow-up of HPV intervention trials or programs. The potential clinical value of urine viral load monitoring should be further investigated. PMID:27196899

  11. Long-Term Follow-up of HPV Infection Using Urine and Cervical Quantitative HPV DNA Testing.

    PubMed

    Vorsters, Alex; Van Keer, Severien; Biesmans, Samantha; Hens, Annick; De Coster, Ilse; Goossens, Herman; Ieven, Margareta; Van Damme, Pierre

    2016-05-17

    The link between infection with high-risk human papillomavirus (hrHPV) and cervical cancer has been clearly demonstrated. Virological end-points showing the absence of persistent HPV infection are now accepted as a way of monitoring the impact of prophylactic vaccination programs and therapeutic vaccine trials. This study investigated the use of urine samples, which can be collected by self-sampling at home, instead of cervical samples for follow-up of an HPV intervention trial. Eighteen initially HPV DNA-positive women participating in an HPV therapeutic vaccine trial were monitored during a three-year follow-up period. A total of 172 urine samples and 85 cervical samples were collected. We obtained a paired urine sample for each of the 85 cervical samples by recovering urine samples from six monthly gynaecological examinations. We performed a small pilot study in which the participating women used a urine collection device at home and returned their urine sample to the laboratory by mail. All samples were analyzed using quantitative real-time HPV DNA PCR. A good association (κ value of 0.65) was found between the presence of HPV DNA in urine and a subsequent cervical sample. Comparisons of the number of HPV DNA copies in urine and paired cervical samples revealed a significant Spearman rho of 0.676. This correlation was superior in women with severe lesions. The HPV DNA results of the small pilot study based on self-collected urine samples at home are consistent with previous and subsequent urine and/or cervical results. We demonstrated that urine sampling may be a valid alternative to cervical samples for the follow-up of HPV intervention trials or programs. The potential clinical value of urine viral load monitoring should be further investigated.

  12. Baby care product development: artificial urine in vitro assay is useful for cosmetic product assessment.

    PubMed

    Degouy, Arnaud; Gomez-Berrada, Marie-Pierre; Ferret, Pierre-Jacques

    2014-02-01

    As a result of infants' inability to control urination, the skin of the diaper area has special needs for protection from irritating effects of urine and prevention of diaper dermatitis such as products for cleansing and protection of the skin. Several in vitro models are currently available to assess tolerance. In vitro testing using artificial urine allows the protective effects of diaper-region cosmetics to be ascertained. Thus, a new model defined as "artificial urine in vitro assay" has been added to our traditional pre-clinical in vitro testing program. IL1-α is a highly active and pleiotropic pro-inflammatory cytokine. It plays a key role in inflammation and is the biological mirror of irritation induced by diaper dermatitis. This study determines, on human skin explants, if a cosmetic formula is (1) tolerated equally as well in the presence of artificial urine as in its absence and (2) is able to decrease IL1-α production induced by artificial urine or Sodium Dodecyl Sulfate. 31 tests including 17 in-house formulas, 10 bench-markers and 4 combinations of products were performed and data obtained are represented on a simple four-point scale (from practically non protective to very protective). It allows determination of formula-type groups that will have predictable protective properties in subsequent clinical trials and comparison with competitors' products. It is a useful aid in the formulation stage and provides readily-useable data for the cosmetic risk assessment. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Doping control container for urine stabilization: a pilot study.

    PubMed

    Tsivou, Maria; Giannadaki, Evangelia; Hooghe, Fiona; Roels, Kris; Van Gansbeke, Wim; Garribba, Flaminia; Lyris, Emmanouil; Deventer, Koen; Mazzarino, Monica; Donati, Francesco; Georgakopoulos, Dimitrios G; Van Eenoo, Peter; Georgakopoulos, Costas G; de la Torre, Xavier; Botrè, Francesco

    2017-05-01

    Urine collection containers used in the doping control collection procedure do not provide a protective environment for urine, against degradation by microorganisms and proteolytic enzymes. An in-house chemical stabilization mixture was developed to tackle urine degradation problems encountered in human sport samples, in cases of microbial contamination or proteolytic activity. The mixture consists of antimicrobial substances and protease inhibitors for the simultaneous inactivation of a wide range of proteolytic enzymes. It has already been tested in lab-scale, as part of World Anti-Doping Agency's (WADA) funded research project, in terms of efficiency against microbial and proteolytic activity. The present work, funded also by WADA, is a follow-up study on the improvement of chemical stabilization mixture composition, application mode and limitation of interferences, using pilot urine collection containers, spray-coated in their internal surface with the chemical stabilization mixture. Urine in plastic stabilized collection containers have been gone through various incubation cycles to test for stabilization efficiency and analytical matrix interferences by three WADA accredited Laboratories (Athens, Ghent, and Rome). The spray-coated chemical stabilization mixture was tested against microorganism elimination and steroid glucuronide degradation, as well as enzymatic breakdown of proteins, such as intact hCG, recombinant erythropoietin and small peptides (GHRPs, ipamorelin), induced by proteolytic enzymes. Potential analytical interferences, observed in the presence of spray-coated chemical stabilization mixture, were recorded using routine screening procedures. The results of the current study support the application of the spray-coated plastic urine container, in the doping control collection procedure. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  14. Ion Exchange Technology Development in Support of the Urine Processor Assembly

    NASA Technical Reports Server (NTRS)

    Mitchell, Julie; Broyan, James; Pickering, Karen

    2013-01-01

    The urine processor assembly (UPA) on the International Space Station (ISS) recovers water from urine via a vacuum distillation process. The distillation occurs in a rotating distillation assembly (DA) where the urine is heated and subjected to sub-ambient pressure. As water is removed, the original organics, salts, and minerals in the urine become more concentrated and result in urine brine. Eventually, water removal will concentrate the urine brine to super saturation of individual constituents, and precipitation occurs. Under typical UPA DA operating conditions, calcium sulfate or gypsum is the first chemical to precipitate in substantial quantity. During preflight testing with ground urine, the UPA achieved 85% water recovery without precipitation. However, on ISS, it is possible that crewmember urine can be significantly more concentrated relative to urine from ground donors. As a result, gypsum precipitated in the DA when operating at water recovery rates at or near 85%, causing the failure and subsequent re14 NASA Tech Briefs, September 2013 placement of the DA. Later investigations have demonstrated that an excess of calcium and sulfate will cause precipitation at water recovery rates greater than 70%. The source of the excess calcium is likely physiological in nature, via crewmembers' bone loss, while the excess sulfate is primarily due to the sulfuric acid component of the urine pretreatment. To prevent gypsum precipitation in the UPA, the Precipitation Prevention Project (PPP) team has focused on removing the calcium ion from pretreated urine, using ion exchange resins as calcium removal agents. The selectivity and effectiveness of ion exchange resins are determined by such factors as the mobility of the liquid phase through the polymer matrix, the density of functional groups, type of functional groups bound to the matrix, and the chemical characteristics of the liquid phase (pH, oxidation potential, and ionic strength). Previous experience with ion exchange resins has demonstrated that the most effective implementation for an ion exchange resin is a cartridge, or column, in which the resin is contained. Based on the results of equilibrium and sub-scale dynamic column testing, a possible solution for mitigating the calcium precipitation issue on the ISS has been identified. From an original pool of 13 ion exchange resins, two candidates have been identified that demonstrate substantial calcium removal on the sub-scale. The dramatic reduction in resin performance from published calcium uptake demonstrates the need for thorough evaluation of resins at the low pH and strong oxidizing environment present in the UPA. Chemical variations in the influent (calcium concentrations and pretreatment dosing) appear to have a noticeable impact on the calcium capacity of the resin. Low calcium concentrations and high pretreatment dosing will likely result in a decrease in calcium capacity. Conversely, low pre trea t - ment dosing will likely result in an increase in calcium capacity. In contrast, investigations at a variety of flow rates, length-to-diameter ratios, resin volumes, and flow regimes (continuous versus pulsed) show that changes in physical parameters do not have substantial impacts on resin performance in the very low specific velocity ranges of interest. This result is particularly useful because most commercial applications at higher specific velocities do show a relatively strong relationship between flow and capacity. The lack of a strong relationship will allow more flexibility in the implementation of an ion exchange bed for flight. Verification of subscale tests with flight-scale resin beds is recommended prior to implementation in the on-orbit UPA.

  15. Epithelial Cells in Urine: MedlinePlus Lab Test Information

    MedlinePlus

    ... page: https://medlineplus.gov/labtests/epithelialcellsinurine.html Epithelial Cells in Urine To use the sharing features on ... page, please enable JavaScript. What is an Epithelial Cells in Urine Test? Epithelial cells are a type ...

  16. The consequence of delayed fixation on subsequent preservation of urine cells.

    PubMed

    Ahmed, Hussain G; Tom, Murtada Am

    2011-01-01

    Degenerative changes caused by delays in urine preservation contribute to false-negative and false-positive interpretation of urothelial disease in cytology. The aim of this study is to assess whether the delay of fixation of urine samples makes any significant difference to urine cytology and morphology, and the limit of acceptability of delay for routine use in the hospital laboratory. Three cell collection fluids were evaluated by analyzing the preservation and degeneration of cells in urine samples. In this study, 50 voided urine specimens were taken at random from females complaining of vaginal discharge. Each specimen was divided into three sterile containers. The first was immediately centrifugated and the deposit was smeared onto a cleaned micro slide and immediately fixed into 95% ethyl alcohol for 15 minutes. The remaining two were prepared in the same manner, however, the second after two hours of collection and the third after four hours of collection. The degree of degeneration and thus the preservation were assessed by a table of chosen criteria, then ranked and analyzed using Friedman's nonparametric test, at p=0.05. The results showed a significant difference between the preservation and the delay in urine fixation, p<0.0001. Any delay in fixation of urine specimen for cytology affects the preservation of cells, which may result in miss diagnosis. It is recommended that urine samples for cytology should be fixed immediately after collection.

  17. Hemoglobinuria Misidentified as Hematuria: Review of Discolored Urine and Paroxysmal Nocturnal Hemoglobinuria

    PubMed Central

    Veerreddy, Prashant

    2013-01-01

    Discolored urine is a common reason for office visits to a primary care physician and urology referral. Early differentiation of the type or cause of discolored urine is necessary for accurate diagnosis and prompt management. Paroxysmal nocturnal hemoglobinuria is a clonal disorder caused by acquired somatic mutations in the PIG-A gene on the X- chromosome of hemopoietic stem cells and leads to deficiency of surface membrane anchor proteins. The deficiency of these proteins leads to an increased risk of hemolysis of erythrocytes and structural damage of platelets, resulting in a clinical syndrome characterized by complement-mediated intravascular hemolytic anemia, bone marrow failure, and venous thrombosis. Patients with this clinical syndrome present with paroxysms of hemolysis, causing hemoglobinuria manifesting as discolored urine. This can be easily confused with other common causes of discolored urine and result in extensive urologic work-up. Three commonly confused entities of discolored urine include hematuria, hemoglobinuria, and myoglobinuria. Specific characteristics in a dipstick test or urinalysis can guide differentiation of these three causes of discolored urine. This article begins with a case summary of a woman presenting with cranberry-colored urine and a final delayed diagnosis of paryxysmal nocturnal hemoglobinuria. Her hemoglobinuria was misdiagnosed as hematuria, leading to extensive urologic work-up. The article also gives an overview of the approach to diagnosing and treating discolored urine. PMID:25512715

  18. Urine toxicology screening in an urban stroke and TIA population.

    PubMed

    Silver, Brian; Miller, Daniel; Jankowski, Michelle; Murshed, Nawaf; Garcia, Patricia; Penstone, Patricia; Straub, Melissa; Logan, Sean P; Sinha, Anita; Morris, Daniel C; Katramados, Angelos; Russman, Andrew N; Mitsias, Panayiotis D; Schultz, Lonni R

    2013-04-30

    We sought to determine the rate of urine toxicology screening, differences in testing, and outcomes among patients with stroke and TIA presenting to a tertiary care emergency department. In this retrospective cohort study, patients admitted with stroke or TIA to a single tertiary care stroke center between June 2005 and January 2007 were identified through a stroke database. Factors that predicted urine toxicology screening of patients and a positive test, and discharge outcomes of patients based on toxicology result were analyzed. Stroke severity, treatment with tissue plasminogen activator, discharge status, and stroke etiology were compared between toxicology positive and negative patients. A total of 1,024 patients were identified: 704 with ischemic stroke, 133 with intracerebral hemorrhage, and 205 with TIA. Urine toxicology screening was performed in 420 patients (40%); 11% of these studies were positive for cocaine (19% younger than 50 years and 9% 50 years or older). Factors that significantly predicted the performance of a urine toxicology screen were younger age (<50 years) and black race (<0.001). Positive toxicology screens occurred in a broad range of patients. There were no significant differences in admission NIH Stroke Scale score, stroke etiology, and discharge status between toxicology-positive and -negative patients. In this study, patients with stroke and TIA who were young and black were more likely to have urine toxicology screening. Eleven percent of all tested patients (and 9% of patients 50 years or older) were positive for cocaine. To avoid disparities, we suggest that all stroke and TIA patients be tested.

  19. Compatibility Testing of Non-Metallic Materials for the Urine Processor Assembly (UPA) of International Space Station (ISS)

    NASA Technical Reports Server (NTRS)

    Wingard, Charles Doug; Munafo, Paul M. (Technical Monitor)

    2001-01-01

    In the International Space Station (ISS), astronauts will convert urine into potable water with the Urine Processor Assembly (UPA). The urine is distilled, with the concentrated form containing about 15% brine solids, and the dilute form as a blend of pre-treated urine/wastewater. Eighteen candidate non-metallic materials for use with the UPA were tested in 2000 for compatibility with the concentrated and dilute urine solutions for continuous times of at least 30 days, and at conditions of 0.5 psia pressure and 100 F, to simulate the working UPA environment. A primary screening test for each material (virgin and conditioned) was dynamic mechanical analysis (DMA) in the stress relaxation mode, with the test data used to predict material performance for a 10-year use in space. Data showed that most of the candidate materials passed the compatibility testing, although a few significant changes in stress relaxation modulus were observed.

  20. Depletion of penicillin G residues in heavy sows after intramuscular injection. Part II: application of kidney inhibition swab tests.

    PubMed

    Shelver, Weilin L; Lupton, Sara J; Newman, David J; Larsen, Steven; Smith, David J

    2014-07-30

    Sows (n = 126; 228 ± 30.1 kg) were administered daily IM doses of penicillin G procaine (33 000 IU/kg bw; 5× the label dose) for 3 consecutive days using three different administration patterns. Within treatment, six sows each were slaughtered on withdrawal day 5, 10, 15, 20, 25, 32, and 39. Tissues (injection site, kidney, liver, skeletal muscle) or body fluids (serum and urine) were screened for penicillin G using the KIS test, recently adopted by the USDA Food Safety and Inspection Service. The IM administration patterns had no discernible effect on penicillin G depletion. Residues were depleted more rapidly from liver and skeletal muscle and more slowly from kidney and urine. Kidney was the most sensitive and suitable tissue for detecting penicillin G residues on-site, with two positive results after a 39-day withdrawal period. Urine was the most suitable ante-mortem surrogate to predict the results of kidney tests.

  1. Improving the Diagnosis of Legionella Pneumonia within a Healthcare System through a Systematic Consultation and Testing Program.

    PubMed

    Decker, Brooke K; Harris, Patricia L; Muder, Robert R; Hong, Jae H; Singh, Nina; Sonel, Ali F; Clancy, Cornelius J

    2016-08-01

    Legionella testing is not recommended for all patients with pneumonia, but rather for particular patient subgroups. As a result, the overall incidence of Legionella pneumonia may be underestimated. To determine the incidence of Legionella pneumonia in a veteran population in an endemic area after introduction of a systematic infectious diseases consultation and testing program. In response to a 2011-2012 outbreak, the VA Pittsburgh Healthcare System mandated infectious diseases consultations and testing for Legionella by urine antigen and sputum culture in all patients with pneumonia. Between January 2013 and December 2015, 1,579 cases of pneumonia were identified. The incidence of pneumonia was 788/100,000 veterans per year, including 352/100,000 veterans per year and 436/100,000 veterans per year with community-associated pneumonia (CAP) and health care-associated pneumonia, respectively. Ninety-eight percent of patients with suspected pneumonia were tested for Legionella by at least one method. Legionella accounted for 1% of pneumonia cases (n = 16), including 1.7% (12/706) and 0.6% (4/873) of CAP and health care-associated pneumonia, respectively. The yearly incidences of Legionella pneumonia and Legionella CAP were 7.99 and 5.99/100,000 veterans, respectively. The sensitivities of urine antigen and sputum culture were 81% and 60%, respectively; the specificity of urine antigen was >99.97%. Urine antigen testing and Legionella cultures increased by 65% and 330%, respectively, after introduction of our program. Systematic testing of veterans in an endemic area revealed a higher incidence of Legionella pneumonia and CAP than previously reported. Widespread urine antigen testing was not limited by false positivity.

  2. Introduction of sample tubes with sodium azide as a preservative for ethyl glucuronide in urine.

    PubMed

    Luginbühl, Marc; Weinmann, Wolfgang; Al-Ahmad, Ali

    2017-09-01

    Ethyl glucuronide (EtG) is a direct alcohol marker, which is widely used for clinical and forensic applications, mainly for abstinence control. However, the instability of EtG in urine against bacterial degradation or the post-collectional synthesis of EtG in contaminated samples may cause false interpretation of EtG results in urine samples. This study evaluates the potential of sodium azide in tubes used for urine collection to hinder degradation of ethyl glucuronide by bacterial metabolism taking place during growth of bacterial colonies. The tubes are part of a commercial oral fluid collection device. The sampling system was tested with different gram-positive and gram-negative bacterial species previously observed in urinary tract infections, such as Escherichia coli, Staphylococcus aureus, Enterecoccus faecalis, Staphylococcus epidermidis, Klebsiella pneumoniae, Enterobacter cloacae, and Pseudomonas aeruginosa. Inhibition of bacterial growth by sodium azide, resulting in lower numbers of colony forming units compared to control samples, was observed for all tested bacterial species. To test the prevention of EtG degradation by the predominant pathogen in urinary tract infection, sterile-filtered urine and deficient medium were spiked with EtG, and inoculated with E. coli prior to incubation for 4 days at 37 °C in tubes with and without sodium azide. Samples were collected every 24 hours, during four consecutive days, whereby the colony forming units (CFU) were counted on Columbia blood agar plates, and EtG was analyzed by LC-MS/MS. As expected, EtG degradation was observed when standard polypropylene tubes were used for the storage of contaminated samples. However, urine specimens collected in sodium azide tubes showed no or very limited bacterial growth and no EtG degradation. As a conclusion, sodium azide is useful to reduce bacterial growth of gram-negative and gram-positive bacteria. It inhibits the degradation of EtG by E. coli and can be used for the stabilization of EtG in urine samples.

  3. [Comparison of the Conventional Centrifuged and Filtrated Preparations in Urine Cytology].

    PubMed

    Sekita, Nobuyuki; Shimosakai, Hirofumi; Nishikawa, Rika; Sato, Hiroaki; Kouno, Hiroyoshi; Fujimura, Masaaki; Mikami, Kazuo

    2016-03-01

    The urine cytology test is one of the most important tools for the diagnosis of malignant urinary tract tumors. This test is also of great value for predicting malignancy. However, the sensitivity of this test is not high enough to screen for malignant cells. In our laboratory, we were able to attain a high sensitivity of urine cytology tests after changing the preparation method of urine samples. The differences in the cytodiagnosis between the two methods are discussed here. From January 2012 to June 2013, 2,031 urine samples were prepared using the conventional centrifuge method (C method) ; and from September 2013 to March 2015, 2,453 urine samples were prepared using the filtration method (F method) for the cytology test. When the samples included in category 4 or 5, were defined as cytological positive, the sensitivities of this test with samples prepared using the F method were significantly high compared with samples prepared using the C method (72% vs 28%, p<0.001). The number of cells on the glass slides prepared by the F method was significantly higher than that of the samples prepared by the C method (p<0.001). After introduction of the F method, the number of f alse negative cases was decreased in the urine cytology test because a larger number of cells was seen and easily detected as atypical or malignant epithelial cells. Therefore, this method has a higher sensitivity than the conventional C method as the sensitivity of urine cytology tests relies partially on the number of cells visualized in the prepared samples.

  4. Sole Dependence on Urine Testing Strips and the Ability to Identify Clinically Significant Disease: Challenging the Current Paradigm for Heme Detection in General Clinical Situations.

    PubMed

    Rothschild, Bruce

    2016-05-01

    The ability of health care professionals to provide patient care is potentially compromised when predicated on untested, although longstanding, perspectives. One such example is urinalysis testing, which has been currently simplified to use only urine testing strips for detection of microscopic hematuria. To determine whether urine testing strips are sufficient for identification of clinically significant findings in urinalysis. To determine the presence of microscopic hematuria, I examined a collection of urine specimens that had tested heme negative during the 3-month study period. Of the 342 patients from whom urine specimens were examined during this interval, 50 had microscopic hematuria, despite having tested negative for heme via urine testing strip. Also, 30% were not receiving any medication known to produce microscopic hematuria, and 18% had clinically significant pathology. Diagnosis of significant clinical pathologic manifestations would have been compromised had microscopic examination not been performed on the urine specimens from the cohort individuals. Examination of the novel approach of including microscopic examination of specimens in a specific clinical situation challenges the dominant paradigm of reliance on assaying using urine testing strips only, revealing that the current method is not only unreliable for determining microscopic hematuria but also is less than optimal in general clinical practice. The findings of this study provide evidence of the importance of microscopic evaluation as a routine component of urinalysis. © American Society for Clinical Pathology, 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  5. Diagnostic accuracy, incremental yield and prognostic value of Determine TB-LAM for routine diagnostic testing for tuberculosis in HIV-infected patients requiring acute hospital admission in South Africa: a prospective cohort.

    PubMed

    Lawn, Stephen D; Kerkhoff, Andrew D; Burton, Rosie; Schutz, Charlotte; Boulle, Andrew; Vogt, Monica; Gupta-Wright, Ankur; Nicol, Mark P; Meintjes, Graeme

    2017-03-21

    We previously reported that one-third of HIV-positive adults requiring medical admission to a South African district hospital had laboratory-confirmed tuberculosis (TB) and that almost two-thirds of cases could be rapidly diagnosed using Xpert MTB/RIF-testing of concentrated urine samples obtained on the first day of admission. Implementation of urine-based, routine, point-of-care TB screening is an attractive intervention that might be facilitated by use of a simple, low-cost diagnostic tool, such as the Determine TB-LAM lateral-flow rapid test for HIV-associated TB. Sputum, urine and blood samples were systematically obtained from unselected HIV-positive adults within 24 hours of admission to a South African township hospital. Additional clinical samples were obtained during hospitalization as clinically indicated. TB was defined by the detection of Mycobacterium tuberculosis in any sample using Xpert MTB/RIF or liquid culture. The diagnostic yield, accuracy and prognostic value of urine-lipoarabinomannan (LAM) testing were determined, but urine-LAM results did not inform treatment decisions. Consecutive HIV-positive adult acute medical admissions not already receiving TB treatment (n = 427) were enrolled regardless of clinical presentation or symptoms. TB was diagnosed in 139 patients (TB prevalence 32.6%; median CD4 count 80 cells/μL). In the first 24 hours of admission, sputum (spot and/or induced) samples were obtained from 37.0% of patients and urine samples from 99.5% of patients (P < 0.001). The diagnostic yields from these specimens were 19.4% (n = 27/139) for sputum-microscopy, 26.6% (n = 37/139) for sputum-Xpert, 38.1% (n = 53/139) for urine-LAM and 52.5% (n = 73/139) for sputum-Xpert/urine-LAM combined (P < 0.01). Corresponding yields among patients with CD4 counts <100 cells/μL were 18.9%, 24.3%, 55.4% and 63.5%, respectively (P < 0.01). The diagnostic yield of urine-LAM was unrelated to respiratory symptoms, and LAM assay specificity (using a grade-2 cut-off) was 98.9% (274/277; 95% confidence interval [CI] 96.9-99.8). Among TB cases, positive urine-LAM status was strongly associated with mortality at 90 days (adjusted hazard ratio 4.20; 95% CI 1.50-11.75). Routine testing for TB in newly admitted HIV-positive adults using Determine TB-LAM to test urine provides major incremental diagnostic yield with very high specificity when used in combination with sputum testing and has important utility among those without respiratory TB symptoms and/or unable to produce sputum. The assay also rapidly identifies individuals with a poor prognosis.

  6. Delta-ALA urine test

    MedlinePlus

    ... hours. Normal value ranges may vary slightly from one lab to another. Some labs use different measurements or test different samples. Talk to your provider about the meaning of your specific test results. What Abnormal Results Mean An increased level of urinary delta-ALA may ...

  7. Evaluation of the Urine Protein/Creatinine Ratio Measured with the Dipsticks Clinitek Atlas PRO 12.

    PubMed

    Hermida, Fernando J; Soto, Sonia; Benitez, Alfonso J

    2016-01-01

    Screening for urine proteins is recommended for the detection of albuminuria in high risk groups. The aim of this study was to compare the Clinitek Atlas PRO12 reagent urine strip with quantitative methods for the determination of protein/creatinine ratio and to evaluate the usefulness of the semi-quantitative Clinitek Atlas PRO12 reagent urine strip as a tool in the early detection of albuminuria among the general population. Six hundred first morning urine specimens were collected from outpatients with various clinical conditions. The results showed that the test data for the urine dipstick Clinitek Atlas PRO12 show good agreement with the quantitative measurement of protein, creatinine and protein/creatinine ratio. In addition, this study shows that 97.2% of the samples which gave "normal" protein/creatinine ratios by the semi-quantitative method, showed albumin/creatinine ratio < 30 mg/g by the quantitative methods. Our results show that Clinitek Atlas PRO12 reagent strips can be used for the purposes of albuminuria screening in the general population.

  8. Usefulness of Leukocyte Esterase Test Versus Rapid Strep Test for Diagnosis of Acute Strep Pharyngitis.

    PubMed

    Nibhanipudi, Kumara V

    2015-01-01

    A study to compare the usage of throat swab testing for leukocyte esterase on a test strip(urine dip stick-multi stick) to rapid strep test for rapid diagnosis of Group A Beta hemolytic streptococci in cases of acute pharyngitis in children. The testing of throat swab for leukocyte esterase on test strip currently used for urine testing may be used to detect throat infection and might be as useful as rapid strep. All patients who come with a complaint of sore throat and fever were examined clinically for erythema of pharynx, tonsils and also for any exudates. Informed consent was obtained from the parents and assent from the subjects. 3 swabs were taken from pharyngo-tonsillar region, testing for culture, rapid strep & Leukocyte Esterase. Total number is 100. Cultures 9(+); for rapid strep== 84(-) and16 (+); For LE== 80(-) and 20(+) From data configuration Rapid Strep versus LE test don't seem to be a random (independent) assignment but extremely aligned. The Statistical results show rapid and LE show very agreeable results. Calculated Value of Chi Squared Exceeds Tabulated under 1 Degree Of Freedom (P<.0.0001) reject Null HYPOTHESIS and Conclude Alternative Conclusions: Leukocyte esterase on throat swab is as useful as rapid strep test for rapid diagnosis of strep pharyngitis on test strip currently used for urine dip stick causing acute pharyngitis in children.

  9. CHROMagar Orientation Medium Reduces Urine Culture Workload

    PubMed Central

    Manickam, Kanchana; Karlowsky, James A.; Adam, Heather; Lagacé-Wiens, Philippe R. S.; Rendina, Assunta; Pang, Paulette; Murray, Brenda-Lee

    2013-01-01

    Microbiology laboratories continually strive to streamline and improve their urine culture algorithms because of the high volumes of urine specimens they receive and the modest numbers of those specimens that are ultimately considered clinically significant. In the current study, we quantitatively measured the impact of the introduction of CHROMagar Orientation (CO) medium into routine use in two hospital laboratories and compared it to conventional culture on blood and MacConkey agars. Based on data extracted from our Laboratory Information System from 2006 to 2011, the use of CO medium resulted in a 28% reduction in workload for additional procedures such as Gram stains, subcultures, identification panels, agglutination tests, and biochemical tests. The average number of workload units (one workload unit equals 1 min of hands-on labor) per urine specimen was significantly reduced (P < 0.0001; 95% confidence interval [CI], 0.5326 to 1.047) from 2.67 in 2006 (preimplementation of CO medium) to 1.88 in 2011 (postimplementation of CO medium). We conclude that the use of CO medium streamlined the urine culture process and increased bench throughput by reducing both workload and turnaround time in our laboratories. PMID:23363839

  10. Comparison of the Abbott RealTime High Risk HPV test and the Roche cobas 4800 HPV test using urine samples.

    PubMed

    Lim, Myong Cheol; Lee, Do-Hoon; Hwang, Sang-Hyun; Hwang, Na Rae; Lee, Bomyee; Shin, Hye Young; Jun, Jae Kwan; Yoo, Chong Woo; Lee, Dong Ock; Seo, Sang-Soo; Park, Sang-Yoon; Joo, Jungnam

    2017-05-01

    Human papillomavirus (HPV) testing based on cervical samples is important for use in cervical cancer screening. However, cervical sampling is invasive. Therefore, non-invasive methods for detecting HPV, such as urine samples, are needed. For HPV detection in urine samples, two real-time PCR (RQ-PCR) tests, Roche cobas 4800 test (Roche_HPV; Roche Molecular Diagnostics) and Abbott RealTime High Risk HPV test (Abbott_HPV; Abbott Laboratories) were compared to standard cervical samples. The performance of Roche_HPV and Abbott_HPV for HPV detection was evaluated at the National Cancer Center using 100 paired cervical and urine samples. The tests were also compared using urine samples stored at various temperatures and for a range of durations. The overall agreement between the Roche_HPV and Abbott_HPV tests using urine samples for any hrHPV type was substantial (86.0% with a kappa value of 0.7173), and that for HPV 16/18 was nearly perfect (99.0% with a kappa value of 0.9668). The relative sensitivities (based on cervical samples) for HPV 16/18 detection using Roche_HPV and Abbott_HPV with urine samples were 79.2% (95% CI; 57.9-92.9%) and 81.8% (95% CI; 59.7-94.8%), respectively. When the cut-off C T value for Abbott_HPV was extended to 40 for urine samples, the relative sensitivity of Abbott_HPV increased to 91.7% from 81.8% for HPV16/18 detection and to 87.0% from 68.5% for other hrHPV detection. The specificity was not affected by the change in the C T threshold. Roche_HPV and Abbott_HPV showed high concordance. However, HPV DNA detection using urine samples was inferior to HPV DNA detection using cervical samples. Interestingly, when the cut-off C T value was set to 40, Abbott_HPV using urine samples showed high sensitivity and specificity, comparable to those obtained using cervical samples. Fully automated DNA extraction and detection systems, such as Roche_HPV and Abbott_HPV, could reduce the variability in HPV detection and accelerate the standardization of HPV detection in urine. Thus, urine samples may be an effective alternative for HPV detection in women who hesitate to participate in cervical cancer screening programs. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. PBG urine test

    MedlinePlus

    ... test. Alternative Names Porphobilinogen test; Porphyria - urine; PBG Images Male urinary system References Fuller SJ, Wiley JS. Heme biosynthesis and its disorders: porphyrias and sideroblastic ...

  12. An optical spot test for the detection of dopamine in human urine using stabilized in air lipid films.

    PubMed

    Nikolelis, Dimitrios P; Drivelos, Dimitrios A; Simantiraki, Maria G; Koinis, Spyros

    2004-04-15

    The present technique describes a simple, sensitive spot test for the rapid one-shot detection of dopamine in human urine using lipid films with incorporated resorcin[4]arene receptor that are synthesized by a chemical reaction with a methacrylate polymer on a glass fiber filter. The lipid films without the receptor provided fluorescence under a UV lamp. The use of the receptor in these films quenched this fluorescence, and the color became similar to that of the filters without the lipid films. A drop of dopamine or urine containing this stimulant provided a "switching on" of the fluorescence, which allows the rapid detection of this stimulant in human urine at 10(-8) M concentrations. The novelty of the present work is that it opens new routes in the field of biosensing, i.e., development of sensitive, rapid, and simple methods for detecting species based on the fluorescence of the lipid membranes on a polymer film, and provides a spot test technique for the rapid detection of dopamine. The effect of potent interferences including a wide range of compounds usually found in human urine (i.e., ascorbic aid, glucose, leucine, glycine, tartrate, citrate, bicarbonate, and caffeine) was examined using an aqueous buffered solution that contained the potent interference and dopamine at two lower concentration levels (i.e., 3 x 10(-8)-10(-8) M). The effect of proteins and lipids was also investigated at these two lower dopamine concentration levels in aqueous buffered solution. The results showed no interferences from all these constituents at concentrations usually found in human urine samples; for example, albumin up to 3.22 g/L concentration levels did not provide any interference (i.e., no fluorescence). A drop of urine containing this stimulant provided similar results, i.e., a "switching on" of the fluorescence that allows a technique for the rapid detection of this stimulant in human urine at 10(-8) M concentrations. The technique is not based on a calibration graph but is a semiquantitative method for the detection of dopamine in real samples of urine that can be complimentary to HPLC methods. The difference in color between the samples containing dopamine at concentration levels of 10(-8)-10(-7) M can be easily distinguished by naked eye and a digital camera. An increase of dopamine concentration from 10(-8) to 10(-7) M makes the color more blue whereas the color of the filters remains purple in the blank test (i.e., addition of a urine sample without dopamine or dopamine at concentration levels of 10(-9) M to the filters that contain the lipid membranes with incorporated receptor). The reproducibility of the method was checked in approximately 100 samples, and all of them were found to provide similar results. Note that it was also found that the colors remain stable in the samples containing dopamine for periods of more than two months.

  13. Circulating antigen tests and urine reagent strips for diagnosis of active schistosomiasis in endemic areas

    PubMed Central

    Ochodo, Eleanor A; Gopalakrishna, Gowri; Spek, Bea; Reitsma, Johannes B; van Lieshout, Lisette; Polman, Katja; Lamberton, Poppy; Bossuyt, Patrick Mm; Leeflang, Mariska Mg

    2015-01-01

    Background Point-of-care (POC) tests for diagnosing schistosomiasis include tests based on circulating antigen detection and urine reagent strip tests. If they had sufficient diagnostic accuracy they could replace conventional microscopy as they provide a quicker answer and are easier to use. Objectives To summarise the diagnostic accuracy of: a) urine reagent strip tests in detecting active Schistosoma haematobium infection, with microscopy as the reference standard; and b) circulating antigen tests for detecting active Schistosoma infection in geographical regions endemic for Schistosoma mansoni or S. haematobium or both, with microscopy as the reference standard. Search methods We searched the electronic databases MEDLINE, EMBASE, BIOSIS, MEDION, and Health Technology Assessment (HTA) without language restriction up to 30 June 2014. Selection criteria We included studies that used microscopy as the reference standard: for S. haematobium, microscopy of urine prepared by filtration, centrifugation, or sedimentation methods; and for S. mansoni, microscopy of stool by Kato-Katz thick smear. We included studies on participants residing in endemic areas only. Data collection and analysis Two review authors independently extracted data, assessed quality of the data using QUADAS-2, and performed meta-analysis where appropriate. Using the variability of test thresholds, we used the hierarchical summary receiver operating characteristic (HSROC) model for all eligible tests (except the circulating cathodic antigen (CCA) POC for S. mansoni, where the bivariate random-effects model was more appropriate). We investigated heterogeneity, and carried out indirect comparisons where data were sufficient. Results for sensitivity and specificity are presented as percentages with 95% confidence intervals (CI). Main results We included 90 studies; 88 from field settings in Africa. The median S. haematobium infection prevalence was 41% (range 1% to 89%) and 36% for S. mansoni (range 8% to 95%). Study design and conduct were poorly reported against current standards. Tests for S. haematobium Urine reagent test strips versus microscopy Compared to microscopy, the detection of microhaematuria on test strips had the highest sensitivity and specificity (sensitivity 75%, 95% CI 71% to 79%; specificity 87%, 95% CI 84% to 90%; 74 studies, 102,447 participants). For proteinuria, sensitivity was 61% and specificity was 82% (82,113 participants); and for leukocyturia, sensitivity was 58% and specificity 61% (1532 participants). However, the difference in overall test accuracy between the urine reagent strips for microhaematuria and proteinuria was not found to be different when we compared separate populations (P = 0.25), or when direct comparisons within the same individuals were performed (paired studies; P = 0.21). When tests were evaluated against the higher quality reference standard (when multiple samples were analysed), sensitivity was marginally lower for microhaematuria (71% vs 75%) and for proteinuria (49% vs 61%). The specificity of these tests was comparable. Antigen assay Compared to microscopy, the CCA test showed considerable heterogeneity; meta-analytic sensitivity estimate was 39%, 95% CI 6% to 73%; specificity 78%, 95% CI 55% to 100% (four studies, 901 participants). Tests for S. mansoni Compared to microscopy, the CCA test meta-analytic estimates for detecting S. mansoni at a single threshold of trace positive were: sensitivity 89% (95% CI 86% to 92%); and specificity 55% (95% CI 46% to 65%; 15 studies, 6091 participants) Against a higher quality reference standard, the sensitivity results were comparable (89% vs 88%) but specificity was higher (66% vs 55%). For the CAA test, sensitivity ranged from 47% to 94%, and specificity from 8% to 100% (4 studies, 1583 participants). Authors' conclusions Among the evaluated tests for S. haematobium infection, microhaematuria correctly detected the largest proportions of infections and non-infections identified by microscopy. The CCA POC test for S. mansoni detects a very large proportion of infections identified by microscopy, but it misclassifies a large proportion of microscopy negatives as positives in endemic areas with a moderate to high prevalence of infection, possibly because the test is potentially more sensitive than microscopy. Plain Language Summary How well do point-of-care tests detect Schistosoma infections in people living inendemic areas? Schistosomiasis, also known as bilharzia, is a parasitic disease common in the tropical and subtropics. Point-of-care tests and urine reagent strip tests are quicker and easier to use than microscopy. We estimate how well these point-of-care tests are able to detect schistosomiasis infections compared with microscopy. We searched for studies published in any language up to 30 June 2014, and we considered the study’s risk of providing biased results. What do the results say? We included 90 studies involving almost 200,000 people, with 88 of these studies carried out in Africa in field settings. Study design and conduct were poorly reported against current expectations. Based on our statistical model, we found: • Among the urine strips for detecting urinary schistosomiasis, the strips for detecting blood were better than those detecting protein or white cells (sensitivity and specificity for blood 75% and 87%; for protein 61% and 82%; and for white cells 58% and 61%, respectively). • For urinary schistosomiasis, the parasite antigen test performance was worse (sensitivity, 39% and specificity, 78%) than urine strips for detecting blood. • For intestinal schistosomiasis, the parasite antigen urine test, detected many infections identified by microscopy but wrongly labelled many uninfected people as sick (sensitivity, 89% and specificity, 55%). What are the consequences of using these tests? If we take 1000 people, of which 410 have urinary schistosomiasis on microscopy testing, then using the strip detecting blood in the urine would misclassify 77 uninfected people as infected, and thus may receive unnecessary treatment; and it would wrongly classify 102 infected people as uninfected, who thus may not receive treatment. If we take 1000 people, of which 360 have intestinal schistosomiasis on microscopy testing, then the antigen test would misclassify 288 uninfected people as infected. These people may be given unnecessary treatment. This test also would wrongly classify 40 infected people as uninfected who thus may not receive treatment. Conclusion of review For urinary schistosomiasis, the urine strip for detecting blood leads to some infected people being missed and some non-infected people being diagnosed with the condition, but is better than the protein or white cell tests. The parasite antigen test is not accurate. For intestinal schistosomiasis, the parasite antigen urine test can wrongly classify many uninfected people as infected. PMID:25758180

  14. Diagnostic Value of the Urine Mucus Test in Childhood Masturbation among Children below 12 Years of Age: A Cross-Sectional Study from Iran

    PubMed Central

    Doust, Zarin Keihani; Shariat, Mamak; Zabandan, Neda; Tabrizi, Aidin; Tehrani, Fatemeh

    2016-01-01

    Background: Childhood masturbation (CM) is considered a variant of normal sexual behavior; however, it is commonly misdiagnosed as epilepsy and movement disorders. As the first study from Iran, we analyzed a large population of infants and children with CM in a case-control study and evaluated the value of mucus in urine analysis as an alternative diagnostic tool for CM. Methods: A total of 623 children referred to the Pediatric Neurology Clinic of Imam Khomeini Hospital for an evaluation of seizure or movement disorders were studied between 2008 and 2011. Totally, 359 children were found to have masturbatory behaviors (Group A) and the rest (264) were assigned to Group B. CM was diagnosed by direct observation. Collected data comprised demographic characteristics, clinical and neurodevelopmental examinations, laboratory findings (particularly urine analysis), and electrocardiography. Results: The age of the children with CM was below 12 years old, and the girl-to-boy ratio was 7:1. Mucus in urine was positive in 357 (99.44%) children in Group A and 22 (8.3%) in Group B (P<0.001). A significant correlation was found between the presence of mucus in urine and masturbatory behaviors (P<0.001). Conclusion: Our findings suggest that the presence of mucus in urine can be used as an alternative laboratory test in children with CM below 12 years old and even in infants (≤24 months old). Further studies are needed to confirm the results. PMID:27365549

  15. Isomorphic red blood cells using automated urine flow cytometry is a reliable method in diagnosis of bladder cancer.

    PubMed

    Muto, Satoru; Sugiura, Syo-Ichiro; Nakajima, Akiko; Horiuchi, Akira; Inoue, Masahiro; Saito, Keisuke; Isotani, Shuji; Yamaguchi, Raizo; Ide, Hisamitsu; Horie, Shigeo

    2014-10-01

    We aimed to identify patients with a chief complaint of hematuria who could safely avoid unnecessary radiation and instrumentation in the diagnosis of bladder cancer (BC), using automated urine flow cytometry to detect isomorphic red blood cells (RBCs) in urine. We acquired urine samples from 134 patients over the age of 35 years with a chief complaint of hematuria and a positive urine occult blood test or microhematuria. The data were analyzed using the UF-1000i (®) (Sysmex Co., Ltd., Kobe, Japan) automated urine flow cytometer to determine RBC morphology, which was classified as isomorphic or dysmorphic. The patients were divided into two groups (BC versus non-BC) for statistical analysis. Multivariate logistic regression analysis was used to determine the predictive value of flow cytometry versus urine cytology, the bladder tumor antigen test, occult blood in urine test, and microhematuria test. BC was confirmed in 26 of 134 patients (19.4 %). The area under the curve for RBC count using the automated urine flow cytometer was 0.94, representing the highest reference value obtained in this study. Isomorphic RBCs were detected in all patients in the BC group. On multivariate logistic regression analysis, only isomorphic RBC morphology was significantly predictive for BC (p < 0.001). Analytical parameters such as sensitivity, specificity, positive predictive value, and negative predictive value of isomorphic RBCs in urine were 100.0, 91.7, 74.3, and 100.0 %, respectively. Detection of urinary isomorphic RBCs using automated urine flow cytometry is a reliable method in the diagnosis of BC with hematuria.

  16. [Use of urine drug screening in the emergency department of a paediatric hospital].

    PubMed

    Ferrer Bosch, Núria; Martínez Sánchez, Lidia; Trenchs Sainz de la Maza, Victoria; Velasco Rodríguez, Jesús; García González, Elsa; Luaces Cubells, Carles

    2018-01-01

    To describe the situations in which urine drug screening is used in a Paediatric Emergency Department (ED). An analysis is also made on its potential usefulness on whether it changes the patient management, and if the results are confirmed by using specific techniques. A retrospective study was conducted on patients under the age of 18 attended in the ED during 2014 and in whom urine drug screening was requested. Depending on the potential capacity of the screening result to change patient management, two groups were defined (potentially useful and not potentially useful). Urine drug screening was performed on a total of 161 patients. The screening was considered not to be potentially useful in 87 (54.0%). This was because the clinical history already explained the symptoms the patient had in 55 (34.1%) patients, in 29 (18.0%) because the patient was asymptomatic, and in 3 (1.9%) because the suspected drug was not detectable in the screening. The drug screening results changed the patient management in 5 (3.1%) cases. A toxic substance was detected in 44 (27.3%). Two out of the 44 that were positive (2.1%) were re-tested by specific techniques, and presence of the toxic substance was ruled out in both of them (false positives). Most of the drug screening tests are not justified, and it is very infrequent that they change patient management. It is very rare that the results are confirmed using more specific methods. Urine drug screening tests should be restricted to particular cases and if the result has legal implications, or if the patient denies using the drug, it should be followed by a specific toxicological study to provide a conclusive result. Copyright © 2016 Asociación Española de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.

  17. Urine Test: Microalbumin-to-Creatinine Ratio (For Parents)

    MedlinePlus

    ... involves measuring the amount of a protein called albumin in the urine (pee). The amount of urine albumin is compared with the quantity of a waste ... steady rate, so comparing the ratio of urine albumin with creatinine in the same urine specimen helps ...

  18. Osmolality urine test

    MedlinePlus

    ... balance and urine concentration. Osmolality is a more exact measurement of urine concentration than the urine specific ... must be authorized in writing by ADAM Health Solutions. About MedlinePlus Site Map FAQs Customer Support Get ...

  19. 24-hour urinary aldosterone excretion test

    MedlinePlus

    Aldosterone - urine; Addison disease - urine aldosterone; Cirrhosis - serum aldosterone ... A 24-hour urine sample is needed. You will need to collect your urine over 24 hours . Your health care provider will tell ...

  20. Serum and urine metabolomic fingerprinting in diagnostics of inflammatory bowel diseases

    PubMed Central

    Dawiskiba, Tomasz; Deja, Stanisław; Mulak, Agata; Ząbek, Adam; Jawień, Ewa; Pawełka, Dorota; Banasik, Mirosław; Mastalerz-Migas, Agnieszka; Balcerzak, Waldemar; Kaliszewski, Krzysztof; Skóra, Jan; Barć, Piotr; Korta, Krzysztof; Pormańczuk, Kornel; Szyber, Przemyslaw; Litarski, Adam; Młynarz, Piotr

    2014-01-01

    AIM: To evaluate the utility of serum and urine metabolomic analysis in diagnosing and monitoring of inflammatory bowel diseases (IBD). METHODS: Serum and urine samples were collected from 24 patients with ulcerative colitis (UC), 19 patients with the Crohn’s disease (CD) and 17 healthy controls. The activity of UC was assessed with the Simple Clinical Colitis Activity Index, while the activity of CD was determined using the Harvey-Bradshaw Index. The analysis of serum and urine samples was performed using proton nuclear magnetic resonance (NMR) spectroscopy. All spectra were exported to Matlab for preprocessing which resulted in two data matrixes for serum and urine. Prior to the chemometric analysis, both data sets were unit variance scaled. The differences in metabolite fingerprints were assessed using partial least-squares-discriminant analysis (PLS-DA). Receiver operating characteristic curves and area under curves were used to evaluate the quality and prediction performance of the obtained PLS-DA models. Metabolites responsible for separation in models were tested using STATISTICA 10 with the Mann-Whitney-Wilcoxon test and the Student’s t test (α = 0.05). RESULTS: The comparison between the group of patients with active IBD and the group with IBD in remission provided good PLS-DA models (P value 0.002 for serum and 0.003 for urine). The metabolites that allowed to distinguish these groups were: N-acetylated compounds and phenylalanine (up-regulated in serum), low-density lipoproteins and very low-density lipoproteins (decreased in serum) as well as glycine (increased in urine) and acetoacetate (decreased in urine). The significant differences in metabolomic profiles were also found between the group of patients with active IBD and healthy control subjects providing the PLS-DA models with a very good separation (P value < 0.001 for serum and 0.003 for urine). The metabolites that were found to be the strongest biomarkers included in this case: leucine, isoleucine, 3-hydroxybutyric acid, N-acetylated compounds, acetoacetate, glycine, phenylalanine and lactate (increased in serum), creatine, dimethyl sulfone, histidine, choline and its derivatives (decreased in serum), as well as citrate, hippurate, trigonelline, taurine, succinate and 2-hydroxyisobutyrate (decreased in urine). No clear separation in PLS-DA models was found between CD and UC patients based on the analysis of serum and urine samples, although one metabolite (formate) in univariate statistical analysis was significantly lower in serum of patients with active CD, and two metabolites (alanine and N-acetylated compounds) were significantly higher in serum of patients with CD when comparing jointly patients in the remission and active phase of the diseases. Contrary to the results obtained from the serum samples, the analysis of urine samples allowed to distinguish patients with IBD in remission from healthy control subjects. The metabolites of importance included in this case up-regulated acetoacetate and down-regulated citrate, hippurate, taurine, succinate, glycine, alanine and formate. CONCLUSION: NMR-based metabolomic fingerprinting of serum and urine has the potential to be a useful tool in distinguishing patients with active IBD from those in remission. PMID:24415869

  1. Diagnostic Accuracy of Urine Protein/Creatinine Ratio Is Influenced by Urine Concentration.

    PubMed

    Yang, Chih-Yu; Chen, Fu-An; Chen, Chun-Fan; Liu, Wen-Sheng; Shih, Chia-Jen; Ou, Shuo-Ming; Yang, Wu-Chang; Lin, Chih-Ching; Yang, An-Hang

    2015-01-01

    The usage of urine protein/creatinine ratio to estimate daily urine protein excretion is prevalent, but relatively little attention has been paid to the influence of urine concentration and its impact on test accuracy. We took advantage of 24-hour urine collection to examine both urine protein/creatinine ratio (UPCR) and daily urine protein excretion, with the latter as the reference standard. Specific gravity from a concomitant urinalysis of the same urine sample was used to indicate the urine concentration. During 2010 to 2014, there were 540 adequately collected 24h urine samples with protein concentration, creatinine concentration, total volume, and a concomitant urinalysis of the same sample. Variables associated with an accurate UPCR estimation were determined by multivariate linear regression analysis. Receiver operating characteristic (ROC) curves were generated to determine the discriminant cut-off values of urine creatinine concentration for predicting an accurate UPCR estimation in either dilute or concentrated urine samples. Our findings indicated that for dilute urine, as indicated by a low urine specific gravity, UPCR is more likely to overestimate the actual daily urine protein excretion. On the contrary, UPCR of concentrated urine is more likely to result in an underestimation. By ROC curve analysis, the best cut-off value of urine creatinine concentration for predicting overestimation by UPCR of dilute urine (specific gravity ≦ 1.005) was ≦ 38.8 mg/dL, whereas the best cut-off values of urine creatinine for predicting underestimation by UPCR of thick urine were ≧ 63.6 mg/dL (specific gravity ≧ 1.015), ≧ 62.1 mg/dL (specific gravity ≧ 1.020), ≧ 61.5 mg/dL (specific gravity ≧ 1.025), respectively. We also compared distribution patterns of urine creatinine concentration of 24h urine cohort with a concurrent spot urine cohort and found that the underestimation might be more profound in single voided samples. The UPCR in samples with low or high specific gravity is more likely to overestimate or underestimate actual daily urine protein amount, respectively, especially in a dilute urine sample with its creatinine below 38.8 mg/dL or a concentrated sample with its creatinine above 61.5 mg/dL. In particular, UPCR results should be interpreted with caution in cases that involve dilute urine samples because its overestimation may lead to an erroneous diagnosis of proteinuric renal disease or an incorrect staging of chronic kidney disease.

  2. Evaluation of a newly designed sandwich enzyme linked immunosorbent assay for the detection of hydatid antigen in serum, urine and cyst fluid for diagnosis of cystic echinococcosis

    PubMed Central

    Chaya, DR; Parija, Subhash Chandra

    2013-01-01

    Introduction: Cystic echinococcosis (CE) is a zoonotic disease of humans with variable clinical manifestations. Imaging and immunological methods are currently the mainstay of diagnosis of this disease. Although the immunological tests for detection of anti-echinococcal antibodies have several disadvantages, they are widely being used. Antigen is far more superior than antibody detection test as they can provide a specific parasitic diagnosis. Materials and Methods: A sandwich enzyme linked immunosorbent assay (ELISA) was designed using antibodies to 24 kDa urinary hydatid antigen for the detection of hydatid antigens in urine, serum and cyst fluid specimens. The performance of this novel test was compared with that of other hydatid antibody detection ELISA and enzyme immune transfer blot (EITB) using radiological and surgical confirmation as the gold standard. Results: The antigen detection ELISA showed 100% sensitivity and specificity when tested with cyst fluid. On testing urine and serum, the antigen detection ELISA was found to be more specific than antibody detection ELISA. EITB was found to be the most sensitive and specific test. Conclusions: ELISA using polyclonal antibodies against 24 kDa urinary hydatid protein was moderately sensitive to detect hydatid antigen in serum and urine. Hence polyclonal antibodies to 24 kDa urinary hydatid antigen can be used as an alternative source of antibody to detect hydatid antigen in serum, urine and cyst fluid. In the present study, EITB was found to be highly specific test for detection of hydatid antibodiesin serum. 24 kDa protein was found to be specific and of diagnostic value in CE. PMID:24470996

  3. Urine analysis concerning xenon for doping control purposes.

    PubMed

    Thevis, Mario; Piper, Thomas; Geyer, Hans; Schaefer, Maximilian S; Schneemann, Julia; Kienbaum, Peter; Schänzer, Wilhelm

    2015-01-15

    On September 1(st) 2014, a modified Prohibited List as established by the World Anti-Doping Agency (WADA) became effective featuring xenon as a banned substance categorized as hypoxia-inducible factor (HIF) activator. Consequently, the analysis of xenon from commonly provided doping control specimens such as blood and urine is desirable, and first data on the determination of xenon from urine in the context of human sports drug testing, are presented. In accordance to earlier studies utilizing plasma as doping control matrix, urine was enriched to saturation with xenon, sequentially diluted, and the target analyte was detected as supported by the internal standard d6 -cyclohexanone by means of gas chromatography/triple quadrupole mass spectrometry (GC/MS/MS) using headspace injection. Three major xenon isotopes at m/z 128.9, 130.9 and 131.9 were targeted in (pseudo) selected reaction monitoring mode enabling the unambiguous identification of the prohibited substance. Assay characteristics including limit of detection (LOD), intraday/interday precision, and specificity as well as analyte recovery under different storage conditions were determined. Proof-of-concept data were generated by applying the established method to urine samples collected from five patients before, during and after (up to 48 h) xenon-based general anesthesia. Xenon was traceable in enriched human urine samples down to the detection limit of approximately 0.5 nmol/mL. The intraday and interday imprecision values of the method were found below 25%, and specificity was demonstrated by analyzing 20 different blank urine samples that corroborated the fitness-for-purpose of the analytical approach to unequivocally detect xenon at non-physiological concentrations in human urine. The patients' urine specimens returned 'xenon-positive' test results up to 40 h post-anesthesia, indicating the limits of the expected doping control detection window. Since xenon has been considered a prohibited substance according to WADA regulations in September 2014, its analysis from common specimens of routine sports drug testing is desirable. In previous studies, its traceability in whole blood and plasma was shown, and herein a complementary approach utilizing doping control urine samples for the GC/MS/MS analysis of xenon was reported. Copyright © 2014 John Wiley & Sons, Ltd.

  4. Development of a new protocol for rapid bacterial identification and susceptibility testing directly from urine samples.

    PubMed

    Zboromyrska, Y; Rubio, E; Alejo, I; Vergara, A; Mons, A; Campo, I; Bosch, J; Marco, F; Vila, J

    2016-06-01

    The current gold standard method for the diagnosis of urinary tract infections (UTI) is urine culture that requires 18-48 h for the identification of the causative microorganisms and an additional 24 h until the results of antimicrobial susceptibility testing (AST) are available. The aim of this study was to shorten the time of urine sample processing by a combination of flow cytometry for screening and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) for bacterial identification followed by AST directly from urine. The study was divided into two parts. During the first part, 675 urine samples were processed by a flow cytometry device and a cut-off value of bacterial count was determined to select samples for direct identification by MALDI-TOF-MS at ≥5 × 10(6) bacteria/mL. During the second part, 163 of 1029 processed samples reached the cut-off value. The sample preparation protocol for direct identification included two centrifugation and two washing steps. Direct AST was performed by the disc diffusion method if a reliable direct identification was obtained. Direct MALDI-TOF-MS identification was performed in 140 urine samples; 125 of the samples were positive by urine culture, 12 were contaminated and 3 were negative. Reliable direct identification was obtained in 108 (86.4%) of the 125 positive samples. AST was performed in 102 identified samples, and the results were fully concordant with the routine method among 83 monomicrobial infections. In conclusion, the turnaround time of the protocol described to diagnose UTI was about 1 h for microbial identification and 18-24 h for AST. Copyright © 2016 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  5. European guidelines for workplace drug testing in urine.

    PubMed

    Taskinen, Sanna; Beck, Olof; Bosch, Tessa; Brcak, Michaela; Carmichael, Duncan; Fucci, Nadia; George, Claire; Piper, Mark; Salomone, Alberto; Schielen, Wim; Steinmeyer, Stefan; Weinmann, Wolfgang

    2017-06-01

    These European Guidelines for Workplace Drug Testing in Urine have been prepared and updated by the European Workplace Drug Testing Society (EWDTS). The first version of these urine guidelines was published in 2002. Since then, the guidelines have been followed by many laboratories in different European countries and their role has been essential particularly in countries lacking legislation for workplace drug testing. In 2014, the EWDTS started a guidelines updating project and published a new version of the urine guidelines in 2015. Here we represent this updated version of the urine guidelines. The European Guidelines are designed to establish best practice procedures whilst allowing individual countries to operate within the requirements of national customs and legislation. The EWDTS recommends that all European laboratories that undertake legally defensible workplace drug testing should use these guidelines as a template for accreditation. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  6. Diagnostic accuracy of rapid urine dipstick test to predict urinary tract infection among pregnant women in Felege Hiwot Referral Hospital, Bahir Dar, North West Ethiopia.

    PubMed

    Demilie, Tazebew; Beyene, Getenet; Melaku, Selabat; Tsegaye, Wondewosen

    2014-07-29

    Untreated bacteriuria during pregnancy has been shown to be associated with low birth-weight and premature delivery. Therefore, routine screening for bacteriuria is advocated. The decision about how to screen pregnant women for bacteriuria has always been a balance between the cost of screening versus the sensitivity and specificity. This study was designed to evaluate the diagnostic accuracy of the rapid dipstick test to predict urinary tract infection in pregnancy against the gold standard urine culture. A total of 367 mid stream urine samples were collected, inoculated on MacConkey, Manitol salt agar (MSA) and blood agar and incubated aerobically at 37°C for overnight. Specimens were classified as "positive" for urinary tract infection (UTI) if the growth of the pathogen(s) was at a count ≥ 10(5) colony-forming units per milliliter (cfu/mL) of urine and classified as "negative" with growth of <10(5) cfu/mL. Urine samples were tested for the presence of nitrite and leukocyte esterase using dipstick rapid test in accordance to the manufacturer's instructions. From the total study participants, 37 pregnant women were symptomatic and the remaining 330 pregnant women were asymptomatic. The sensitivity and specificity of dipstick tests of leukocyte esterase was 50% and 89.1% for pregnant women with asymptomatic UTI(ABU) and 71.4% and 86.7% for symptomatic UTI respectively and for nitrite 35.7% and 98.0% for ABU and 57.1% and 96.7% symptomatic UTI. This study revealed that the use of dipstick leukocyte esterase and nitrite for screening UTI particularly asymptomatic bacteriuria was associated with many false positive and negative results when it was compared against the gold standard culture method. The low sensitivity and positive predictive value of urine dipstick test proved that culture should be used for the diagnosis of UTI.

  7. Naltrexone treatment for opioid dependence: Does its effectiveness depend on testing the blockade?

    PubMed Central

    Sullivan, Maria A.; Bisaga, Adam; Mariani, John J.; Glass, Andrew; Levin, Frances R.; Comer, Sandra D.; Nunes, Edward V.

    2013-01-01

    Background FDA approval of long-acting injectable naltrexone (Vivitrol) for opioid dependence highlights the relevance of understanding mechanisms of antagonist treatment. Principles of learning suggest an antagonist works through extinguishing drug-seeking behavior, as episodes of drug use (“testing the blockade”) fail to produce reinforcement. We hypothesized that opiate use would moderate the effect of naltrexone, specifically, that opiate-positive urines precede dropout in the placebo group, but not in the active-medication groups. Methods An 8-week, double-blind, placebo-controlled trial (N=57), compared the efficacy of low (192-mg) and high (384-mg) doses of a long-acting injectable naltrexone (Depotrex) with placebo (Comer et al., 2006). A Cox proportional hazard model was fit, modeling time-to-dropout as a function of treatment assignment and urine toxicology during treatment. Results Interaction of opiate urines with treatment group was significant. Opiate-positive urines predicted dropout on placebo and low-dose, but less so on high-dose naltrexone, where positive urines were more likely followed by sustained abstinence. Among patients with no opiate-positive urines, retention was higher in both low- and high-dose naltrexone conditions, compared to placebo. Conclusions Findings confirm that injection naltrexone produces extinction of drug-seeking behavior after episodes of opiate use. Adequate dosage appears important, as low-dose naltrexone resembled the placebo group; opiate positive urines were likely to be followed by dropout from treatment. The observation of high treatment retention among naltrexone-treated patients who do not test the blockade, suggests naltrexone may also exert direct effects on opiate-taking behavior that do not depend on extinction, perhaps by attenuating craving or normalizing dysregulated hedonic or neuroendocrine systems. PMID:23827259

  8. Development of a preprototype vapor compression distillation water recovery subsystem

    NASA Technical Reports Server (NTRS)

    Johnson, K. L.

    1978-01-01

    The activities involved in the design, development, and test of a preprototype vapor compression distillation water recovery subsystem are described. This subsystem, part of a larger regenerative life support evaluation system, is designed to recover usable water from urine, urinal rinse water, and concentrated shower and laundry brine collected from three space vehicle crewmen for a period of 180 days without resupply. Details of preliminary design and testing as well as component developments are included. Trade studies, considerations leading to concept selections, problems encountered, and test data are also presented. The rework of existing hardware, subsystem development including computer programs, assembly verification, and comprehensive baseline test results are discussed.

  9. To signal or not to signal? Chemical communication by urine-borne signals mirrors sexual conflict in crayfish

    PubMed Central

    2010-01-01

    Background Sexual selection theory predicts that females, being the limiting sex, invest less in courtship signals than males. However, when chemical signals are involved it is often the female that initiates mating by producing stimuli that inform about sex and/or receptivity. This apparent contradiction has been discussed in the literature as 'the female pheromone fallacy'. Because the release of chemical stimuli may not have evolved to elicit the male's courtship response, whether these female stimuli represent signals remains an open question. Using techniques to visualise and block release of urine, we studied the role of urine signals during fighting and mating interactions of crayfish (Pacifastacus leniusculus). Test individuals were blindfolded to exclude visual disturbance from dye release and artificial urine introduction. Results Staged female-male pairings during the reproductive season often resulted in male mating attempts. Blocking female urine release in such pairings prevented any male courtship behaviour. Artificial introduction of female urine re-established male mating attempts. Urine visualisation showed that female urine release coincides with aggressive behaviours but not with female submissive behaviour in reproductive interactions as well as in intersexual and intrasexual fights. In reproductive interactions, females predominately released urine during precopulatory aggression; males subsequently released significantly less urine during mating than in fights. Conclusions Urine-blocking experiments demonstrate that female urine contains sex-specific components that elicit male mating behaviour. The coincidence of chemical signalling and aggressive behaviour in both females and males suggests that urine release has evolved as an aggressive signal in both sexes of crayfish. By limiting urine release to aggressive behaviours in reproductive interactions females challenge their potential mating partners at the same time as they trigger a sexual response. These double messages should favour stronger males that are able to overcome the resistance of the female. We conclude that the difference between the sexes in disclosing urine-borne information reflects their conflicting interests in reproduction. Males discontinue aggressive urine signalling in order to increase their chances of mating. Females resume urine signalling in connection with aggressive behaviour, potentially repelling low quality or sexually inactive males while favouring reproduction with high quality males. PMID:20353555

  10. Zika Virus Testing Considerations: Lessons Learned from the First 80 Real-Time Reverse Transcription-PCR-Positive Cases Diagnosed in New York State.

    PubMed

    St George, Kirsten; Sohi, Inderbir S; Dufort, Elizabeth M; Dean, Amy B; White, Jennifer L; Limberger, Ronald; Sommer, Jamie N; Ostrowski, Stephanie; Wong, Susan J; Backenson, P Bryon; Kuhles, Daniel; Blog, Debra; Taylor, Jill; Hutton, Brad; Zucker, Howard A

    2017-02-01

    The performance and interpretation of laboratory tests for Zika virus (ZKV) continue to be evaluated. Serology is cross-reactive, laborious, and frequently difficult to interpret, and serum was initially solely recommended for molecular diagnosis. ZKV testing was initiated in January 2016 in New York State for symptomatic patients, pregnant women, their infants, and patients with Guillain-Barré syndrome who had traveled to areas with ZKV transmission. Subsequently, eligibility was expanded to pregnant women with sexual partners with similar travel histories. Serum and urine collected within 4 weeks of symptom onset or within 6 weeks of travel were tested with real-time reverse transcription-PCR (RT-PCR) assays targeting the ZKV envelope and NS2B genes. In this review of lessons learned from the first 80 positive cases in NYS, ZKV RNA was detected in urine only in 50 patients, in serum only in 19 patients, and in both samples concurrently in 11 patients, with average viral loads in urine a log higher than those in serum. Among 93 positive samples from the 80 patients, 41 were positive on both gene assays, 52 were positive on the envelope only, and none were positive on the NS2B only. Of the 80 infected patients, test results for 74 (93%) would have defined their infection status as not detected or equivocal if the requirement for positive results from two assay targets (two-target-positive requirement) in the initial federal guidance to public health laboratories was enforced, if urine was not tested, or if the extended eligibility time for molecular testing was not implemented. These changes facilitated more extensive molecular diagnosis of ZKV, reducing reliance on time-consuming and potentially inconclusive serology. Copyright © 2017 American Society for Microbiology.

  11. Postal urine specimens: are they a feasible method for genital chlamydial infection screening?

    PubMed Central

    Macleod, J; Rowsell, R; Horner, P; Crowley, T; Caul, E O; Low, N; Smith, G D

    1999-01-01

    BACKGROUND: A United Kingdom (UK) screening programme for Chlamydia trachomatis has recently been announced. Pilot projects involving the opportunistic testing of women attending health facilities are due to commence in several sites. There is a danger that this approach will fail to obtain adequate population coverage. The alternative--true systematic population screening--is generally assumed to be unfeasible. Studies in Denmark using postal urine specimens have challenged this assumption. No such studies have been reported from the UK. AIM: To assess the potential of urine specimens sent by post as the basis for a UK population screening strategy for genital chlamydial infection. METHOD: Two hundred patients (100 men, 100 women) aged 18 to 45 years were randomly sampled from the list of one urban group practice. Subjects were mailed an explanatory letter, a urine sample container, a sexual lifestyle questionnaire, and a prepaid return envelope. Non-responders were contacted by telephone; persistent non-responders were visited at home. Samples were tested for Chlamydia by DNA amplification and enzyme immunoassay. RESULTS: Sixty-four (32%) subjects were no longer living at their GP registered address. Of the remaining 136, 126 (93%) responded to the survey and 113 (83%) accepted the request for a urine sample and completed a questionnaire. Acceptance rates were similar for men and women and across age groups. Four samples (3%) were Chlamydia positive. CONCLUSION: Home mailed urine specimen collection in conjunction with a self-completed postal questionnaire is feasible. This could provide a viable basis both for determining population Chlamydia prevalence and for a UK Chlamydia population screening strategy. Overall cost effectiveness of such a strategy will depend on the cost of the test used. Comparative performance characteristics of the different currently available tests in this setting have yet to be fully determined. PMID:10562745

  12. Impact of probability estimation on frequency of urine culture requests in ambulatory settings.

    PubMed

    Gul, Naheed; Quadri, Mujtaba

    2012-07-01

    To determine the perceptions of the medical community about urine culture in diagnosing urinary tract infections. The cross-sectional survey based of consecutive sampling was conducted at Shifa International Hospital, Islamabad, on 200 doctors, including medical students of the Shifa College of Medicine, from April to October 2010. A questionnaire with three common clinical scenarios of low, intermediate and high pre-test probability for urinary tract infection was used to assess the behaviour of the respondents to make a decision for urine culture test. The differences between the reference estimates and the respondents' estimates of pre- and post-test probability were assessed. The association of estimated probabilities with the number of tests ordered was also evaluated. The respondents were also asked about the cost effectiveness and safety of urine culture and sensitivity. Data was analysed using SPSS version 15. In low pre-test probability settings, the disease probability was over-estimated, suggesting the participants' inability to rule out the disease. The post-test probabilities were, however, under-estimated by the doctors as compared to the students. In intermediate and high pre-test probability settings, both over- and underestimation of probabilities were noticed. Doctors were more likely to consider ordering the test as the disease probability increased. Most of the respondents were of the opinion that urine culture was a cost-effective test and there was no associated potential harm. The wide variation in the clinical use of urine culture necessitates the formulation of appropriate guidelines for the diagnostic use of urine culture, and application of Bayesian probabilistic thinking to real clinical situations.

  13. Microbial and Antibiotic Susceptibility Profile among Clinical Samples of Patients with Acute Leukemia.

    PubMed

    Abdollahi, Alireza; Hakimi, Faezeh; Doomanlou, Mahsa; Azadegan, Azadeh

    2016-04-01

    Preventing and starting early treatment of infections in patients whose immunity system is weak due to malignancies like leukemia can reduce mortality. This study aimed to determine microbial and antibiotic resistance patterns in clinical samples of patients with acute leukemia to start early treatment before the results of clinical tests are known. In this cross-sectional study, the clinical samples of all patients hospitalized with the diagnosis of acute leukemia were cultured and their antibiogram was evaluated. Then, the data were analyzed by SPSS 18 based on the objectives of the study. Of a total of 2,366 samples, 18.95% were reported to be positive blood samples, 22.96% were reported to be urine samples and 36% wound samples. E. coli was the most common bacteria isolated from the blood and urine cultures (34% in blood, 32% in urine culture) while Staphylococcus Aureus was the most common in the wound culture (35%). The highest level of sensitivity in the organisms with positive blood culture was to Ciprofloxacin, while in positive urine and wound culture was to Imipenem. The highest resistance in blood, urine and wound culture was to Cotrimoxazole. According to results obtained from this study, it is necessary to conduct appropriate studies on this issue in specific conditions in our country. The findings of this study can be used in clinics for more accurate diagnosis, more effective treatment before the results of clinical tests are known and also for prevention of infection in cancer patients.

  14. The impact on accuracy and cost of ligase chain reaction testing by pooling urine specimens for the diagnosis of Chlamydia trachomatis infections.

    PubMed

    Krepel, J; Patel, J; Sproston, A; Hopkins, F; Jang, D; Mahony, J; Chernesky, M

    1999-10-01

    Nucleic acid amplification testing is the most accurate approach to diagnosing Chlamydia trachomatis infections. Our objective was to compare the accuracy and cost savings of pooling urines as opposed to individual testing. Strategies of pooling urine specimens into groups of four (4x pool) or eight (8x pool) followed by testing the positive pools individually were compared to individual specimen testing to determine if significant cost savingS could be realized without compromising the sensitivity and specificity of the LCx C. trachomatis Assay (Abbott Laboratories, Abbott Park, Chicago, IL) performed in a busy private medical laboratory. A total of 1,220 patient urine samples, 1,187 male (97%) and 33 female (3%), were tested using the normal LCx specimen to cutoff ratio (S/CO) of 1.0 and a decreased S/CO value of 0.2. Individual testing identified 98.2% (109/111) of positive urines. The 4x pooling maneuver identified 92.8% (103/111) of positive patients with the regular cutoff and 96.4% (107/111) when the cutoff was decreased. These values were 95.9% (47/49) and 97.9% (48/49), respectively, when eight urines were pooled. Both pooling and individual testing strategies identified all the negative samples accurately. Cost savings of pooling were calculated to be 44.5% for pools of four and 37.5% for pools of eight, applying the lowered cutoff. Pooling urine specimens for testing with the C. trachomatis LCx system is a simple, accurate, and cost-saving approach that can significantly reduce the cost of amplified nucleic acid testing with minimal sacrifice of testing accuracy.

  15. NMR-based urine analysis in rats: prediction of proximal tubule kidney toxicity and phospholipidosis.

    PubMed

    Lienemann, Kai; Plötz, Thomas; Pestel, Sabine

    2008-01-01

    The aim of safety pharmacology is early detection of compound-induced side-effects. NMR-based urine analysis followed by multivariate data analysis (metabonomics) identifies efficiently differences between toxic and non-toxic compounds; but in most cases multiple administrations of the test compound are necessary. We tested the feasibility of detecting proximal tubule kidney toxicity and phospholipidosis with metabonomics techniques after single compound administration as an early safety pharmacology approach. Rats were treated orally, intravenously, inhalatively or intraperitoneally with different test compounds. Urine was collected at 0-8 h and 8-24 h after compound administration, and (1)H NMR-patterns were recorded from the samples. Variation of post-processing and feature extraction methods led to different views on the data. Support Vector Machines were trained on these different data sets and then aggregated as experts in an Ensemble. Finally, validity was monitored with a cross-validation study using a training, validation, and test data set. Proximal tubule kidney toxicity could be predicted with reasonable total classification accuracy (85%), specificity (88%) and sensitivity (78%). In comparison to alternative histological studies, results were obtained quicker, compound need was reduced, and very importantly fewer animals were needed. In contrast, the induction of phospholipidosis by the test compounds could not be predicted using NMR-based urine analysis or the previously published biomarker PAG. NMR-based urine analysis was shown to effectively predict proximal tubule kidney toxicity after single compound administration in rats. Thus, this experimental design allows early detection of toxicity risks with relatively low amounts of compound in a reasonably short period of time.

  16. Use of urine testing in outpatients treated for urinary tract infection.

    PubMed

    Copp, Hillary L; Yiee, Jenny H; Smith, Alexandria; Hanley, Janet; Saigal, Christopher S

    2013-09-01

    To characterize urine test use in ambulatory, antibiotic-treated pediatric urinary tract infection (UTI). We studied children <18 years who had an outpatient UTI and a temporally associated antibiotic prescription from 2002 through 2007 by using a large claims database, Innovus i3. We evaluated urine-testing trends and performed multivariable logistic regression to assess for factors associated with urine culture use. Of 40 603 treated UTI episodes in 28 678 children, urinalysis was performed in 76%, and urine culture in 57%; 32% of children <2 years had no urinalysis or culture performed for an antibiotic-treated UTI episode. Urine culture use decreased during the study period from 60% to 54% (P < .001). We observed variation in urine culture use with age (<2 years: odds ratio [OR] 1.0, 95% confidence interval [CI] 0.9-1.1; 2-5 years: OR 1.3, 95% CI 1.2-1.4; 6-12 years: OR 1.3, 95% CI 1.2-1.4, compared with 13-17 years); gender (boys: OR 0.8, 95% CI 0.8-0.9); and specialty (pediatrics: OR 2.6, 95% CI 2.5-2.8; emergency medicine, OR 1.2, 95% CI 1.1-1.3; urology: OR 0.5, 95% CI 0.4-0.6, compared with family/internal medicine). Recent antibiotic exposure (OR 1.1, 95% CI 1.1-1.2) and empirical broad-spectrum prescription (OR 1.2, 95% CI 1.1-1.2) were associated with urine culture use, whereas previous UTI and urologic anomalies were not. Providers often do not obtain urine tests when prescribing antibiotics for outpatient pediatric UTI. Variation in urine culture use was observed based on age, gender, and physician specialty. Additional research is necessary to determine the implications of empirical antibiotic prescription for pediatric UTI without confirmatory urine testing.

  17. RAPID DIAGNOSIS OF PNEUMOCOCCAL PNEUMONIA AMONG HIV-INFECTED ADULTS WITH URINE ANTIGEN DETECTION

    PubMed Central

    Boulware, David R; Daley, Charles L.; Merrifield, Cynthia; Hopewell, Philip C.; Janoff, Edward N.

    2007-01-01

    Objectives Streptococcus pneumoniae is the leading cause of bacterial pneumonia and associated bacteremia during HIV infection. Rapid diagnostic assays may limit inappropriate therapy. Methods Clinical signs and symptoms and sera and urine were collected prospectively from 70 adults with pneumococcal pneumonia, including 47 with HIV co-infection. Pneumococcal C-polysaccharide antigen was detected in urine using the Binax® immunochromatographic test (ICT). A systematic review of 24 published studies was conducted. Results Clinical symptoms, signs, and laboratory parameters except leukocytosis, were similar in HIV-infected and HIV-seronegative pneumonia. The performance of the urine antigen ICT was independent of HIV-status (sensitivity 81%, specificity 98%, positive (PPV) and negative predictive values (NPV) 98%, and 82%, respectively). The sensitivity of sputum Gram’s stain was 58% [34/59] with sputum unable to be provided by 16%. The CRP response was identical in HIV-infected (mean ± SD) 133 ± 88 vs. seronegative 135 ± 104 mg/L (p=0.9). In the systematic review, the ICT performance revealed 74% sensitivity (95% CI: 72% to 77%) and 94% specificity (95% CI: 93% to 95%). Urine antigen testing increases etiologic diagnosis by 23% (Range: 10% –59%) when testing adults with community acquired pneumonia of unknown etiology. Conclusions Urinary antigen detection provides a credible rapid diagnostic test for pneumococcal pneumonia regardless of HIV-status. CRP response to acute infection is similar in HIV co-infection and increases diagnostic certainty. PMID:17692384

  18. Preventing Precipitation in the ISS Urine Processor

    NASA Technical Reports Server (NTRS)

    Muirhead, Dean; Carter, Layne; Williamson, Jill; Chambers, Antja

    2017-01-01

    The ISS Urine Processor Assembly (UPA) was initially designed to achieve 85% recovery of water from pretreated urine on ISS. Pretreated urine is comprised of crew urine treated with flush water, an oxidant (chromium trioxide), and an inorganic acid (sulfuric acid) to control microbial growth and inhibit precipitation. Unfortunately, initial operation of the UPA on ISS resulted in the precipitation of calcium sulfate at 85% recovery. This occurred because the calcium concentration in the crew urine was elevated in microgravity due to bone loss. The higher calcium concentration precipitated with sulfate from the pretreatment acid, resulting in a failure of the UPA due to the accumulation of solids in the Distillation Assembly. Since this failure, the UPA has been limited to a reduced recovery of water from urine to prevent calcium sulfate from reaching the solubility limit. NASA personnel have worked to identify a solution that would allow the UPA to return to a nominal recovery rate of 85%. This effort has culminated with the development of a pretreatment based on phosphoric acid instead of sulfuric acid. By eliminating the sulfate associated with the pretreatment, the brine can be concentrated to a much higher concentration before calcium sulfate reach the solubility limit. This paper summarizes the development of this pretreatment and the testing performed to verify its implementation on ISS.

  19. Vapor Compression Distillation Urine Processor Lessons Learned from Development and Life Testing

    NASA Technical Reports Server (NTRS)

    Hutchens, Cindy F.; Long, David A.

    1999-01-01

    Vapor Compression Distillation (VCD) is the chosen technology for urine processing aboard the International Space Station (155). Development and life testing over the past several years have brought to the forefront problems and solutions for the VCD technology. Testing between 1992 and 1998 has been instrumental in developing estimates of hardware life and reliability. It has also helped improve the hardware design in ways that either correct existing problems or enhance the existing design of the hardware. The testing has increased the confidence in the VCD technology and reduced technical and programmatic risks. This paper summarizes the test results and changes that have been made to the VCD design.

  20. CHANGES IN URINE MARKERS AND SYMPTOMS AFTER BLADDER DISTENTION FOR INTERSTITIAL CYSTITIS

    PubMed Central

    Erickson, Deborah R.; Kunselman, Allen R.; Bentley, Christina M.; Peters, Kenneth M.; Rovner, Eric S.; Demers, Laurence M.; Wheeler, Marcia A.; Keay, Susan K.

    2008-01-01

    Purpose To evaluate changes in urine markers and symptom scores after bladder distention in interstitial cystitis (IC) patients. Materials and Methods Subjects were 33 new patients with no prior IC treatments. Urine specimens were taken before and one month after bladder distention. University of Wisconsin (UW) symptom scores were done the same day as the urine specimen collection. Urine marker levels and symptom scores before and after distention were compared. Changes in markers were tested for associations with changes in symptom scores and other markers. Pre-distention markers and specific pre-distention symptoms were tested for their association with post-distention symptom improvement. Results After distention, the median total UW score decreased significantly (28.5 before, 10 after, p<0.001). Twelve patients (36%) had at least 30% improvement in UW score, and eight patients (24%) had at least 50% improvement. No pre-distention markers or symptoms predicted which patients would have a good response. Two of the urine markers improved significantly after distention: anti-proliferative factor (APF) activity (median −96% before, −17% after, p< 0.001) and heparin binding-epidermal growth factor-like growth factor (HB-EGF) levels (median 0.34 ng/mg creatinine before, 4.1 after, p<0.001). None of the changes in urine markers associated with changes in symptom scores. Conclusions The median symptom score for newly diagnosed IC patients decreased after distention, but only a minority of patients had at least 30% symptom improvement. Bladder distention altered urine APF activity and HB-EGF levels towards normal, but the mechanism of symptom relief after distention is still unknown. PMID:17222633

  1. Analytical precision of the Urolizer for the determination of the BONN-Risk-Index (BRI) for calcium oxalate urolithiasis and evaluation of the influence of 24-h urine storage at moderate temperatures on BRI.

    PubMed

    Berg, Wolfgang; Bechler, Robin; Laube, Norbert

    2009-01-01

    Since its first publication in 2000, the BONN-Risk-Index (BRI) has been successfully used to determine the calcium oxalate (CaOx) crystallization risk from urine samples. To date, a BRI-measuring device, the "Urolizer", has been developed, operating automatically and requiring only a minimum of preparation. Two major objectives were pursued: determination of Urolizer precision, and determination of the influence of 24-h urine storage at moderate temperatures on BRI. 24-h urine samples from 52 CaOx stone-formers were collected. A total of 37 urine samples were used for the investigation of Urolizer precision by performing six independent BRI determinations in series. In total, 30 samples were taken for additional investigation of urine storability. Each sample was measured thrice: directly after collection, after 24-h storage at T=21 degrees C, and after 24-h cooling at T=4 degrees C. Outcomes were statistically tested for identity with regard to the immediately obtained results. Repeat measurements for evaluation of Urolizer precision revealed statistical identity of data (p-0.05). 24-h storage of urine at both tested temperatures did not significantly affect BRI (p-0.05). The pilot-run Urolizer shows high analytical reliability. The innovative analysis device may be especially suited for urologists specializing in urolithiasis treatment. The possibility for urine storage at moderate temperatures without loss of analysis quality further demonstrates the applicability of the BRI method.

  2. Evaluation of urovysion and cytology for bladder cancer detection: a study of 1835 paired urine samples with clinical and histologic correlation.

    PubMed

    Dimashkieh, Haythem; Wolff, Daynna J; Smith, T Michael; Houser, Patricia M; Nietert, Paul J; Yang, Jack

    2013-10-01

    Urine cytology has been used for screening of bladder cancer but has been limited by its low sensitivity. UroVysion is a multiprobe fluorescence in situ hybridization (FISH) assay that detects common chromosome abnormalities in bladder cancers. For this study, the authors evaluated the effectiveness of multiprobe FISH and urine cytology in detecting urothelial cell carcinoma (UCC) in the same urine sample. In total, 1835 cases with the following criteria were selected: valid results from both the multiprobe FISH assay and urine cytology in the same urine sample, histologic and/or cystoscopic follow-up within 4 months of the original tests, or at least 3 years of clinical follow-up information. The results of FISH and cytology were correlated with clinical outcomes derived from a combination of histologic, cystoscopic, and clinical follow-up information. Of 1835 cases, 1045 cases were from patients undergoing surveillance of recurrent UCC, and 790 were for hematuria. The overall sensitivity, specificity, positive predictive value, and negative predictive value in detecting UCC were 61.9%, 89.7%, 53.9%, and 92.4%, respectively, for FISH and 29.1%, 96.9%, 64.4%, and 87.5%, respectively, for cytology. The performance of both FISH and cytology generally was better in the surveillance population and in samples with high-grade UCC. In 95 of 296 cases with atypical cytology that were proven to have UCC, 61 cases, mostly high-grade UCC, were positive using the multiprobe FISH assay. The UroVysion multiprobe FISH assay was more sensitive than urine cytology in detecting UCC, but it produced more false-positive results. The current data suggest that the use of FISH as a reflex test after an equivocal cytologic diagnosis may play an effective role in detecting UCC. © 2013 American Cancer Society.

  3. Evaluation of the Sysmex UF1000i flow cytometer for ruling out bacterial urinary tract infection.

    PubMed

    De Rosa, Rita; Grosso, Shamanta; Bruschetta, Graziano; Avolio, Manuela; Stano, Paola; Modolo, Maria Luisa; Camporese, Alessandro

    2010-08-05

    Urine culture is one of the most frequently requested tests in microbiology, and it represents the gold standard for the diagnosis of UTIs. Considering the high prevalence of negative results and the long TAT of the culture test, the use of a rapid and reliable screening method is becoming more and more important, as it reduces the workload, the TAT of negative results, and above all, unnecessary antibiotic prescription. The Sysmex UF1000i is a new urine flow cytometry analyzer capable of quantifying urinary particles, including BACT, WBCs, and YLCs. To evaluate the analytical performance of the UF1000i as a method for ruling out UTIs, we examined 1349 urine samples and compared the UF1000i results with standard urine culture results. With instrument cut-off values of 170BACTx10(6)/L and 150WBCsx10(6)/L, we obtained a sensitivity of 98.8%, a specificity of 76.5%, a NPV of 99.5%, and four false negative results (1.2%), avoiding the culture of 57.1% of samples. The Sysmex UF1000i was capable of improving the efficiency of a routine microbiology laboratory by processing 100samples/h and providing negative results in a few minutes, thus reducing unnecessary testing with an acceptable number of false negative results. In addition, the preliminary evaluation of B_FSC and B_FLH parameters from bacteria histograms seems to be useful for the distinction of bacterial strains detected (Gram-negatives versus Gram-positives). In fact when B_FSC was less than 30 ch, it allowed the distinction of Gram-negative bacteria in 97% of the samples. Copyright 2010 Elsevier B.V. All rights reserved.

  4. Diagnosis and effects of urine contamination in cooled-extended stallion semen.

    PubMed

    Ellerbrock, R; Canisso, I; Feijo, L; Lima, F; Shipley, C; Kline, K

    2016-04-15

    Urospermia is known to affect semen quality in many mammals, including stallions. Determinations of semen pH and creatinine and urea concentrations have been used to diagnose urine contamination in raw stallion semen. Unfortunately, practitioners suspecting urine contamination in cooled-shipped samples have no proven means to confirm the presence of urine. Therefore, the objectives of this study were (1) to assess the effects of urine contamination on sperm motility of extended fresh and cooled-stored stallion semen, (2) to evaluate the usefulness of semen color, odor, pH, and creatinine and urea concentrations for urospermia diagnosis, and (3) to evaluate the accuracy of a commercial blood urea nitrogen test strip in diagnosing urine contamination in extended-cooled stallion semen. Thirty-seven ejaculates were obtained from 11 stallions with no history of urospermia before division into 5 mL aliquots, and contamination with stallion urine. Each resulting sample was assessed for sperm motility, color, odor, pH, creatinine, and urea nitrogen concentration using both a semiquantitative test strip (Azostix), and a quantitative automated analyzer before and after cooling for 24 hour. Sperm motility parameters, pH, and creatinine and urea concentrations were analyzed using mixed models. Urine contamination decreased total and progressive motility in all samples before and after cooling (P < 0.05). Mean control total motility was 80% at 0 hour and 67% at 24 hours, whereas urine-contaminated samples ranged from 30% to 71% at 0 hour and 27% to 61% at 24 hours. Control mean urea (29 mg/dL) and creatinine (0.6 mg/dL) concentrations were significantly different (P < 0.05) from all urine-contaminated samples (158 mg/dL and 11.6 mg/dL, respectively) at 0 hour. Similarly, control mean urea (8 mg/dL) and creatinine (0.9 mg/dL) concentrations were significantly different than all urine-contaminated samples at 24 hours. Odor assessment presented moderate sensitivity (65%) and high specificity (100%), while color assessment presented low sensitivity (47%) and moderate specificity (79%) for urine in extended semen. Azostix strips were highly sensitive (95%) and specific (97%). Assessment of color, odor, and pH are not reliable methods to diagnose urine in experimentally contaminated cooled-stored stallion semen. Sperm motility parameters (in raw and cooled semen) are significantly reduced by the presence of urine in a concentration dependent. The results of the present study indicated that determination of urea and creatinine concentrations can be used to diagnose urospermia and that Azostix can be used as a point care method for diagnosing urine contamination in extended cooled stallion semen. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Lateral Flow Urine Lipoarabinomannan Assay (LF-LAM) for Diagnosis of Active Tuberculosis in HIV-Infected Adults: a Prospective Cohort Study

    PubMed Central

    Na Songkhla, Munjit; Tantipong, Hutsaya; Tongsai, Sasima; Angkasekwinai, Nasikarn

    2017-01-01

    Abstract Background Early diagnosis and treatment of active tuberculosis (TB) in HIV-positive patients is challenging. Tests based on the detection of mycobacterial lipoarabinomannan (LAM) antigen in urine have emerged as potential point-of-care tests for TB. However, limited data exists on their performance among HIV-TB co-infected patients from Southeast Asian countries. Methods We prospectively recruited HIV-positive adult patients with CD4 count less than or equal to 200/mm3 and symptoms suspected of active TB from two tertiary hospitals between December 2015 and March 2017. Freshly collected urine was applied to the Determine®-TB LAM Ag test strip (4 bands of graded intensity), using grade 1 cutoff. Diagnostic accuracy of urine LAM strip test were assessed against microbiological reference standard, defined as positive Mycobacterium tuberculosis cultured from one or more clinical specimens (definite TB) or composite reference standard including definite TB and probable TB, defined as those have symptoms consistent with TB and response to anti-TB treatment. Results A total of 280 patients were enrolled. Of whom, 72 (25.7%) and 65 (23.2%) had definite and probable TB. Amongst those with definite TB, LF-LAM test gave a sensitivity of 75.0% (95% CI 63.9–83.6), specificity of 86.0% (95% CI 79.4–90.8) and accuracy of 82.3% (95% CI 76.7–86.8). When compared with the composite reference standard, the test yielded a lower sensitivity (61.3%, 95% CI 53.0–69.1) and accuracy (73.9%, 95% CI 68.5–78.7), with equal specificity. The test showed the highest sensitivity (90.5%, 95% CI 77.9–96.2) and accuracy (85.9%, 95% CI 79.2–90.7) but lower specificity (84.0%, 95% CI 75.6–89.9) in HIV-infected patients with CD4 count less than 50/mm3. The sensitivity of the combined LF-LAM or sputum microscopy was higher than that of either test alone (86.1% vs. 75.0%, 61.1%, respectively). Mycobacterium avium complex (MAC) was cultured in 7 out of 20 with false positive result. Urine LAM strip test can remain positive for up to 4 weeks even after anti-TB treatment. Conclusion Urine LAM assay gave the best performance for diagnosis of active TB in advanced HIV-infected patients and provide an additional benefit of a greater simplicity, speed, with a more easily obtainable sample. Disclosures All authors: No reported disclosures.

  6. Monitoring cocaine use and abstinence among cocaine users for contingency management interventions.

    PubMed

    Holtyn, August F; Knealing, Todd W; Jarvis, Brantley P; Subramaniam, Shrinidhi; Silverman, Kenneth

    2017-06-01

    During contingency management interventions, reinforcement of cocaine abstinence is arranged by delivering an incentive when a urine sample tests cocaine-negative. The use of qualitative versus quantitative urinalysis testing may have important implications for effects on cocaine abstinence. Qualitative testing (i.e., testing that solely identifies whether a particular substance is present or absent) may not detect short-term cocaine abstinence because a single instance of cocaine use can result in cocaine-positive urine over many days. Quantitative testing (i.e., testing that identifies how much of a substance is present) may be more sensitive to short-term cocaine abstinence; however, the selection of a criterion for distinguishing new use versus carryover from previous use is an important consideration. The present study examined benzoylecgonine concentrations, the primary metabolite of cocaine, in urine samples collected three times per week for 30 weeks from 28 cocaine users who were exposed to a cocaine abstinence contingency. Of the positive urine samples (benzoylecgonine concentration >300 ng/ml), 29%, 21%, 14%, and 5% of the samples decreased in benzoylecgonine concentration by more than 20%, 40%, 60%, and 80% per day, respectively. As the size of the decrease increased, the likelihood of that sample occurring during a period leading to a cocaine-negative urine sample (benzoylecgonine concentration ≤300 ng/ml) also increased. The number of days required to produce a cocaine-negative sample following a positive sample ranged from 1 to 10 days and was significantly correlated with the starting benzoylecgonine level ( r = 0.43, p < 0.001). The present analyses may aid in the development of procedures that allow for the precise reinforcement of recent cocaine abstinence during contingency management interventions.

  7. Laboratory aspects of asymptomatic bacteriuria in pregnancy.

    PubMed

    Mohammad, Marlyn; Mahdy, Zaleha A; Omar, Jamil; Maan, Noorashikin; Jamil, M A

    2002-09-01

    A total of 1,661 pregnant women aged between 13 and 45 years were screened for bacteriuria by urine culture. Of the 1,661 culture results, 615 (37%) yielded no growth; 728 (43.8%) yielded no significant growth (presence of <10(5) organisms/ml urine of one or more types of bacteria); 286 (17.2%) yielded mixed growth (presence of >10(5) organisms/ml urine of more than one type of bacteria) and only 32 (1.9%) showed significant growth (presence of >10(5) organisms/ml urine of a single bacterium). Urine microscopy was also conducted. Two hundred and twenty-four (13.5%) specimens had >10 white blood cells/ml urine, of which 66 had >100 white blood cells; 13 were from the significant growth group. Three hundred and seventy-four (22.5%) specimens showed the presence of bacteria, 42 (2.5%) had red blood cells, 370 (22.3%) had epithelial cells, 58 (3.5%) had crystals, and 14 (0.8%) had yeasts. The most common bacterium isolated was Escherichia coli (12; 40%); the others included group B Streptococcus (5; 15%), Klebsiella spp (5; 15%), Diphtheroids (2), and Candida albicans (2). Fifty-two percent of tested strains were sensitive to ampicillin; 24 of 28 strains (85.7%) were sensitive to ciprofloxacin; all 7 strains tested were sensitive to nitrofurantoin and all 20 strains tested were sensitive to cotrimoxazole; 14/20 (70%) and 16/17 (94.1%) were sensitive to cephalexin and cefuroxime respectively. This study shows that asymptomatic bacteriuria does occur in pregnant women, albeit at a very low rate in an urban setting like Cheras. Urine microscopy is not specific and only serves as a guide to bacteriuria. The commonest causative organisms are those from the gastrointestinal tract and vagina. The antibiogram showed that cefuroxime and cephalexin are likely to be effective in treating bacteriuria: ampicillin must be reserved for Gram-negative organisms. For Gram-positive organisms, of which Group B Streptococcus is important, ampicillin is still effective in vitro. Nitrofurantion and cotrimoxazole have excellent activity in vitro and should be considered for therapy. 17.2% of the urine culture yielded mixed growth: likely to indicate that contamination of urine specimens still happens despite the strict instructions given to patients about the collection of a midstream urine specimen. Proper collection, appropriate transport, and the early processing of urine specimens remain essential.

  8. Kidney Tests

    MedlinePlus

    ... taking out waste products and making urine. Kidney tests check to see how well your kidneys are working. They include blood, urine, and imaging tests. Early kidney disease usually does not have signs ...

  9. Cutoff values for bacteria and leukocytes for urine sediment analyzer FUS200 in culture-positive urinary-tract infections.

    PubMed

    Kocer, Derya; Sarıguzel, Fatma M; Karakukcu, Cıgdem

    2014-08-01

    The microscopic analysis of urine is essential for the diagnosis of patients with urinary tract infections. Quantitative urine culture is the 'gold standard' method for definitive diagnosis of urinary-tract infections, but it is labor-intensive, time consuming, and does not provide the same-day results. The aim of this study was to evaluate the analytical and diagnostic performance of the FUS200 (Changchun Dirui Industry, China), a new urine sedimentation analyzer in comparison to urine culture as the reference method. We evaluated 1000 urine samples, submitted for culture and urine analysis with a preliminary diagnosis of urinary-tract infection. Cut-off values for the FUS200 were determined by comparing the results with urine cultures. The cut-off values by the receiver operating characteristic (ROC) curve technique, sensitivity, and specificity were calculated for bacteria and white blood cells (WBCs). Among the 1000 urine specimens submitted for culture, 637 cultures (63.7%) were negative, and 363 were (36.3%) positive. The best cut-off values obtained from ROC analysis were 16/μL for bacteriuria (sensitivity: 82.3%, specificity: 58%), and 34/μL for WBCs (sensitivity: 72.3%, specificity: 65.2%). The area under the curve (AUC) for the bacteria and WBCs count were 0.71 (95% CI: 0.67-0.74) and, 0.72 (95% CI: 0.69-0.76) respectively. The most important requirement of a rapid diagnostic screening test is sensitivity, and, in this perspective, an unsatisfactory sensitivity by using bacteria recognition and quantification performed by the FUS200 analyzer has been observed. After further technical improvements in particle recognition and laboratory personnel training, the FUS200 might show better results.

  10. Value of Routine Dengue Diagnostic Tests in Urine and Saliva Specimens

    PubMed Central

    Andries, Anne-Claire; Duong, Veasna; Ly, Sowath; Cappelle, Julien; Kim, Kim Srorn; Lorn Try, Patrich; Ros, Sopheaktra; Ong, Sivuth; Huy, Rekol; Horwood, Paul; Flamand, Marie; Sakuntabhai, Anavaj; Tarantola, Arnaud; Buchy, Philippe

    2015-01-01

    Background Dengue laboratory diagnosis is essentially based on detection of the virus, its components or antibodies directed against the virus in blood samples. Blood, however, may be difficult to draw in some patients, especially in children, and sampling during outbreak investigations or epidemiological studies may face logistical challenges or limited compliance to invasive procedures from subjects. The aim of this study was to assess the possibility of using saliva and urine samples instead of blood for dengue diagnosis. Methodology/Principal Findings Serial plasma, urine and saliva samples were collected at several time-points between the day of admission to hospital until three months after the onset of fever in children with confirmed dengue disease. Quantitative RT-PCR, NS1 antigen capture and ELISA serology for anti-DENV antibody (IgG, IgM and IgA) detection were performed in parallel on the three body fluids. RT-PCR and NS1 tests demonstrated an overall sensitivity of 85.4%/63.4%, 41.6%/14.5% and 39%/28.3%, in plasma, urine and saliva specimens, respectively. When urine and saliva samples were collected at the same time-points and tested concurrently, the diagnostic sensitivity of RNA and NS1 detection assays was 69.1% and 34.4%, respectively. IgG/IgA detection assays had an overall sensitivity of 54.4%/37.4%, 38.5%/26.8% and 52.9%/28.6% in plasma, urine and saliva specimens, respectively. IgM were detected in 38.1% and 36% of the plasma and saliva samples but never in urine. Conclusions Although the performances of the different diagnostic methods were not as good in saliva and urine as in plasma specimens, the results obtained by qRT-PCR and by anti-DENV antibody ELISA could well justify the use of these two body fluids to detect dengue infection in situations when the collection of blood specimens is not possible. PMID:26406240

  11. Study of removal of ammonia from urine vapor by dual catalyst

    NASA Technical Reports Server (NTRS)

    Budininkas, P.

    1976-01-01

    The feasibility of ammonia removal from urine vapor by a low temperature dual-catalyst system was investigated. The process is based on the initial catalytic oxidation of ammonia present in urine vapor to nitrogen and nitrous oxide, followed by a catalytic decomposition of the nitrous oxide formed into its elements. The most active catalysts for the oxidation of ammonia and for the decomposition of N2O, identified in screening tests, were then combined into dual catalyst systems and tested to establish their overall efficiencies for the removal of ammonia from artificial gas mixtures. Dual catalyst systems capable of ammonia removal from the artificial gas mixtures were then tested with the actual urine vapor produced by boiling untreated urine. A suitable dual catalyst bed arrangement was found that achieved the removal of ammonia and organic carbon, and recovered water of good quality from urine vapor.

  12. Dipstick measurements of urine specific gravity are unreliable

    PubMed Central

    Roessingh, A; Drukker, A; Guignard, J

    2001-01-01

    AIM—To evaluate the reliability of dipstick measurements of urine specific gravity (U-SG).
METHODS—Fresh urine specimens were tested for urine pH and osmolality (U-pH, U-Osm) by a pH meter and an osmometer, and for U-SG by three different methods (refractometry, automatic readout of a dipstick (Clinitek-50), and (visual) change of colour of the dipstick).
RESULTS—The correlations between the visual U-SG dipstick measurements and U-SG determined by a refractometer and the comparison of Clinitek®-50 dipstick U-SG measurements with U-Osm were less than optimal, showing very wide scatter of values. Only the U-SG refractometer values and U-Osm had a good linear correlation. The tested dipstick was unreliable for the bedside determination of U-SG, even after correction for U-pH, as recommended by the manufacturer.
CONCLUSIONS—Among the bedside determinations, only refractometry gives reliable U-SG results. Dipstick U-SG measurements should be abandoned.

 PMID:11466191

  13. Development and validation of a highly sensitive urine-based test to identify patients with colonic adenomatous polyps.

    PubMed

    Wang, Haili; Tso, Victor; Wong, Clarence; Sadowski, Dan; Fedorak, Richard N

    2014-03-20

    Adenomatous polyps are precursors of colorectal cancer; their detection and removal is the goal of colon cancer screening programs. However, fecal-based methods identify patients with adenomatous polyps with low levels of sensitivity. The aim or this study was to develop a highly accurate, prototypic, proof-of-concept, spot urine-based diagnostic test using metabolomic technology to distinguish persons with adenomatous polyps from those without polyps. Prospective urine and stool samples were collected from 876 participants undergoing colonoscopy examination in a colon cancer screening program, from April 2008 to October 2009 at the University of Alberta. Colonoscopy reference standard identified 633 participants with no colonic polyps and 243 with colonic adenomatous polyps. One-dimensional nuclear magnetic resonance spectra of urine metabolites were analyzed to define a diagnostic metabolomic profile for colonic adenomas. A urine metabolomic diagnostic test for colonic adenomatous polyps was established using 67% of the samples (un-blinded training set) and validated using the other 33% of the samples (blinded testing set). The urine metabolomic diagnostic test's specificity and sensitivity were compared with those of fecal-based tests. Using a two-component, orthogonal, partial least-squares model of the metabolomic profile, the un-blinded training set identified patients with colonic adenomatous polyps with 88.9% sensitivity and 50.2% specificity. Validation using the blinded testing set confirmed sensitivity and specificity values of 82.7% and 51.2%, respectively. Sensitivities of fecal-based tests to identify colonic adenomas ranged from 2.5 to 11.9%. We describe a proof-of-concept spot urine-based metabolomic diagnostic test that identifies patients with colonic adenomatous polyps with a greater level of sensitivity (83%) than fecal-based tests.

  14. The Impact of Using Different Methods to Assess Completeness of 24-Hour Urine Collection on Estimating Dietary Sodium.

    PubMed

    Wielgosz, Andreas; Robinson, Christopher; Mao, Yang; Jiang, Ying; Campbell, Norm R C; Muthuri, Stella; Morrison, Howard

    2016-06-01

    The standard for population-based surveillance of dietary sodium intake is 24-hour urine testing; however, this may be affected by incomplete urine collection. The impact of different indirect methods of assessing completeness of collection on estimated sodium ingestion has not been established. The authors enlisted 507 participants from an existing community study in 2009 to collect 24-hour urine samples. Several methods of assessing completeness of urine collection were tested. Mean sodium intake varied between 3648 mg/24 h and 7210 mg/24 h depending on the method used. Excluding urine samples collected for longer or shorter than 24 hours increased the estimated urine sodium excretion, even when corrections for the variation in timed collections were applied. Until an accurate method of indirectly assessing completeness of urine collection is identified, the gold standard of administering para-aminobenzoic acid is recommended. Efforts to ensure participants collect complete urine samples are also warranted. ©2015 Wiley Periodicals, Inc.

  15. High Prevalence of Sterile Pyuria in the Setting of Sexually Transmitted Infection in Women Presenting to an Emergency Department.

    PubMed

    Shipman, Stacia B; Risinger, Chelsea R; Evans, Crystalle M; Gilbertson, Chelsey D; Hogan, David E

    2018-03-01

    The clinical presentations for sexually transmitted infections (STI) and urinary tract infections (UTI) often overlap, and symptoms of dysuria and urinary frequency/urgency occur with both STIs and UTIs. Abnormal urinalysis (UA) findings and pyuria are common in both UTIs and STIs, and confirmatory urine cultures are not available to emergency clinicians to aid in decision-making regarding prescribing antibiotics for UTIs. The objective of this study was to determine the frequency of sterile pyuria in women with confirmed STIs, as well as whether the absolute number of leukocytes on microscopy or nitrite on urine dipstick correlated with positive urine cultures in patients with confirmed STIs. We also sought to determine how many patients with STIs were inappropriately prescribed a UTI antibiotic. We performed a retrospective chart review of patients aged 18-50 who had a urinalysis and pelvic examination in the emergency department (including cervical cultures), and tested positive for Neisseria gonorrhoeae, Chlamydia trachomatis, and/or Trichomonas vaginalis. Descriptive statistics were obtained for all variables, and associations between various findings were sought using the Fisher's exact test for categorical variables. We calculated comparison of proportions using the N-1 chi-squared analysis. A total of 1,052 female patients tested positive for Neisseria gonorrhoeae, Chlamydia trachomatis, and/or Trichomonas vaginalis and were entered into the database. The prevalence of pyuria in all cases was 394/1,052, 37% (95% confidence interval [CI] [0.34-0.40]). Of the cases with pyuria, 293/394, 74% (95% CI [0.70-0.78]) had sterile pyuria with negative urine cultures. The prevalence of positive urine cultures in our study population was 101/1,052, 9.6% (95% CI [0.08-0.11]). Culture positive urines had a mean of 34 leukocytes per high-power field, and culture negative urines had a mean of 24 leukocytes per high-power field, with a difference of 10, (95% CI [3.46-16.15]), which was statistically significant (p=0.003). Only 123 cases tested positive for nitrite on the urinalysis dipstick; 50/123, 41% (95% CI [0.32-0.49]) had positive urine cultures, and 73/123, 59% (95% CI [0.51-0.68]) had negative urine cultures. Nitrite-positive urines were actually 18% more likely to be associated with negative urine cultures in the setting of positive STI cases, (95% CI [4.95-30.42], p=0.0048). Antibiotics were prescribed for 295 patients with suspected UTI. Of these, 195/295, 66% (95% CI [0.61-0.71]) had negative urine cultures, and 100/295, 34% (0.33, 95% CI [0.28-0.39]) had positive urine cultures. Chi-square analysis yielded a difference of these proportions of 32% (95% CI [23.92-39.62], p<0.0001). This study demonstrated that in female patients with STIs who have pyuria, there is a high prevalence of sterile pyuria. Our results suggest that reliance on pyuria or positive nitrite for the decision to add antimicrobial therapy empirically for a presumed urinary tract infection in cases in which an STI is confirmed or highly suspected is likely to result in substantial over-treatment.

  16. The influence of freezer storage of urine samples on the BONN-Risk-Index for calcium oxalate crystallization.

    PubMed

    Laube, Norbert; Zimmermann, Diana J

    2004-01-01

    This study was performed to quantify the effect of a 1-week freezer storage of urine on its calcium oxalate crystallization risk. Calcium oxalate is the most common urinary stone material observed in urolithiasis patients in western and affluent countries. The BONN-Risk-Index of calcium oxalate crystallization risk in human urine is determined from a crystallization experiment performed on untreated native urine samples. We tested the influence of a 1-week freezing on the BONN-Risk-Index value as well as the effect of the sample freezing on the urinary osmolality. In vitro crystallization experiments in 49 native urine samples from stone-forming and non-stone forming individuals were performed in order to determine their calcium oxalate crystallization risk according to the BONN-Risk-Index approach. Comparison of the results derived from original sample investigations with those obtained from the thawed aliquots by statistical evaluation shows that i) no significant deviation from linearity between both results exists and ii) both results are identical by statistical means. This is valid for both, the BONN-Risk-Index and the osmolality data. The differences in the BONN-Risk-Index results of both procedures of BONN-Risk-Index determination, however, exceed the clinically acceptable difference. Thus, determination of the urinary calcium oxalate crystallization risk from thawed urine samples cannot be recommended.

  17. Can routine automated urinalysis reduce culture requests?

    PubMed

    Kayalp, Damla; Dogan, Kubra; Ceylan, Gozde; Senes, Mehmet; Yucel, Dogan

    2013-09-01

    There are a substantial number of unnecessary urine culture requests. We aimed to investigate whether urine dipstick and microscopy results could accurately rule out urinary tract infection (UTI) without urine culture. The study included a total of 32,998 patients (11,928 men and 21,070 women, mean age: 39 ± 32 years) with a preliminary diagnosis of UTI and both urinalysis and urinary culture were requested. All urine cultures were retrospectively reviewed; association of culture positivity with a positive urinalysis result for leukocyte esterase (LE) and nitrite in chemical analysis and pyuria (WBC) and bacteriuria in microscopy was determined. Diagnostic performance of urinalysis parameters for detection of UTI was evaluated. In total, 758 (2.3%) patients were positive by urine culture. Out of these culture positive samples, ratios of positive dipstick results for LE and nitrite were 71.0% (n=538) and 17.7% (n=134), respectively. The positive microscopy results for WBC and bacteria were 68.2% (n=517) and 78.8% (n=597), respectively. Negative predictive values for LE, nitrite, bacteriuria and WBC were very close to 100%. Most of the samples have no or insignificant bacterial growth. Urine dipstick and microscopy can accurately rule out UTI. Automated urinalysis is a practicable and faster screening test which may prevent unnecessary culture requests for majority of patients. © 2013. Published by Elsevier Inc. All rights reserved.

  18. Can the Griess Nitrite Test and a Urinary Pus Cell Count of ≥5 Cells Per Micro Litre of Urine in Pregnant Women be Used for the Screening or the Early Detection of Urinary Tract Infections in Rural India?

    PubMed Central

    Thakre, Sushama S.; Dhakne, Supriya S.; Thakre, Subhash B.; Thakre, Amol D.; Ughade, Suresh M.; Kale, Priya

    2012-01-01

    Objectives Urinary Tract Infection (UTI) is a common problem in pregnancy due to the morphological and the physiological changes that take place in the genitourinary tract during pregnancy. Screening methods may be useful, because a full bacteriological analysis could be reserved for those patients who are symptomatic or those who have positive screening test results. The exact prevalence of UTI in rural, pregnant women is unknown. The present study was undertaken to estimate the prevalence of UTI in pregnant women and for ascertaining the utility of the Griess Nitrite test and the Urinary Pus Cell Count of ≥5 cells per micro litre test for the screening or the early detection of UTI in them at primary health care clinics. Occurrence of urinary complaints was compared in UTI and non UTI women. Method We conducted a study on 300 randomly selected, pregnant women from rural areas. Urine cultures, pus-cell counts and the Griess nitrite test were used for diagnosis of UTI. The screening tests for UTI were evaluated in terms of their sensitivity, specificity, Positive Predictive Value (PPV), Negative Predictive Value (NPV) and the percentage of correctly classified. Results In the present study, the prevalence of UTI was found to be 29/300 (9.6%, 95% confidence interval 9.57-9.63). The specificities of the two screening tests were comparable (97.05% and 94.47%). Also, the negative predictive values of the two tests were almost similar (97.77% and 96.96%). The percentage of correctly classified by the Griess nitrite test and the urine pus cell count were found to be 95.33% and 92.33% respectively. The proportion of the women with various urinary complaints was significantly higher (P<0.00) in the UTI subjects as compared to that in the non-UTI subjects. Conclusion Urine culture remains the gold standard for the detection of asymptomatic bacteriuria. The Nitrite test of uncentrifuged urine was observed to be the best among the screening tests which were evaluated in terms of their efficiency and validity. PMID:23285444

  19. Intermediate water recovery system

    NASA Technical Reports Server (NTRS)

    Deckman, G.; Anderson, A. R. (Editor)

    1973-01-01

    A water recovery system for collecting, storing, and processing urine, wash water, and humidity condensates from a crew of three aboard a spacecraft is described. The results of a 30-day test performed on a breadboard system are presented. The intermediate water recovery system produced clear, sterile, water with a 96.4 percent recovery rate from the processed urine. Recommendations for improving the system are included.

  20. Swift and Certain, Proportionate and Consistent: Key Values of Urine Drug Test Consequences for Probationers.

    PubMed

    Cadwallader, Amy B

    2017-09-01

    Traditionally, urine drug testing (UDT) in the correctional population (both prison and community corrections) has been infrequent, is scheduled, and has a high possibility of delayed results. Of practical relevance is that scheduled testing is ineffective for identifying drug misuse. Of ethical relevance is that consequences of positive scheduled tests can be unpredictable-in the form of overly severe punishment or a lack of treatment options-and that the scheduled testing paradigm is a poor way to change behaviors. More innovative programs now use a UDT paradigm with more frequent, random testing providing rapid results and certain, swift consequences and addiction treatment when warranted or requested. Studies have shown these new programs-the foundation of which is frequent, random UDTs-to significantly reduce drug use, criminal recidivism, and incarceration. © 2017 American Medical Association. All Rights Reserved.

  1. Evaluation of a new amplified enzyme immunoassay (EIA) for the detection of Chlamydia trachomatis in male urine, female endocervical swab, and patient obtained vaginal swab specimens

    PubMed Central

    Tanaka, M.; Nakayama, H.; Sagiyama, K.; Haraoka, M.; Yoshida, H.; Hagiwara, T.; Akazawa, K.; Naito, S.

    2000-01-01

    Aims—To compare the performance of a new generation dual amplified enzyme immunoassay (EIA) with a molecular method for the diagnosis of Chlamydia trachomatis, using a range of urogenital samples, and to assess the reliability of testing self collected vaginal specimens compared with clinician collected vaginal specimens. Methods—Two population groups were tested. For the first population group, first void urine samples were collected from 193 male patients with urethritis, and endocervical swabs were collected from 187 high risk commercial sex workers. All urine and endocervical specimens were tested by a conventional assay (IDEIA chlamydia), a new generation amplified immunoassay (IDEIA PCE chlamydia), and the Amplicor polymerase chain reaction (PCR). Discrepant results obtained among the three sample types were confirmed using a nested PCR test with a different plasmid target region. For the second population group, four swab specimens, including one patient obtained vaginal swab, two clinician obtained endocervical swabs, and one clinician obtained vaginal swab, were collected from 91 high risk sex workers. Self collected and clinician collected vaginal swabs were tested by IDEIA PCE chlamydia. Clinician obtained endocervical swabs were assayed by IDEIA PCE chlamydia and Amplicor PCR. Results—The performance of the IDEIA PCE chlamydia test was comparable to that of the Amplicor PCR test when male urine and female endocervical swab specimens were analysed. The relative sensitivities of IDEIA, IDEIA PCE, and Amplicor PCR on male first void urine specimens were 79.3%, 91.4%, and 100%, respectively. The relative sensitivities of the three tests on female endocervical specimens were 85.0%, 95.0%, and 100%, respectively. The positivity rates for patient collected vaginal specimens and clinician collected vaginal specimens by IDEIA PCE were 25.2% and 23.1%, respectively, whereas those for clinician collected endocervical swabs by PCR and IDEIA PCE were both 27.5%. Conclusions—IDEIA PCE chlamydia is a lower cost but sensitive alternative test to PCR for testing male urine samples and female endocervical swabs. In addition, self collected or clinician collected vaginal specimens tested by IDEIA PCE chlamydia are a reliable alternative to analysing endocervical specimens. Key Words: Chlamydia trachomatis • enzyme immunoassay • clinical specimens PMID:10889816

  2. Primary health care providers surveyed commonly misinterpret 'first void urine' for chlamydia screening.

    PubMed

    Lusk, M Josephine; Uddin, Ruby; Ferson, Mark; Rawlinson, William; Konecny, Pam

    2009-03-01

    An open question survey of general practitioners (GP) and hospital emergency department (ED) doctors revealed that the term 'FVU' (first void urine) used for urine chlamydia testing, is ambiguous, potentially leading to incorrect urine sample collection and barriers to effective screening. The results of this survey indicate that only 4.3% (95% confidence interval [CI] 0.5-14.5%) of GP and 6.9% (95% CI 0.9-22.8%) of ED doctors respectively, correctly interpreted the meaning of FVU. The majority of clinicians surveyed misunderstood 'FVU' to require the first urine void of the day, accounting for 68.1% (95% CI 52.9-80.9%) of GP responses and 37.9% (95% CI 20.7-57.7%) of ED doctors responses. This highlights the need for clarification and standardisation of terminology used in urine chlamydia screening for health care providers, in order to optimise strategies for diagnosis and control of the ongoing chlamydia epidemic.

  3. Does UTI cause prolonged jaundice in otherwise well infants?

    PubMed

    Chowdhury, Tanzila; Kisat, Hamudi; Tullus, Kjell

    2015-07-01

    The symptoms of urinary tract infections in infants are very non-specific and have historically included prolonged hyperbilirubinaemia. We studied the results of routine urine samples in 319 infants with prolonged jaundice. Convincing findings of UTI was not found in any of these children even if one of them was treated with antibiotics after four consecutive urine cultures with different bacteria. A urine culture might thus not be an appropriate investigation in a child with prolonged jaundice without any other symptoms of UTI. • The symptoms of UTI in infancy are very non-specific. • Old studies suggest that prolonged hyperbilirubinaemia is one such symptom; more modern studies give more conflicting results. What is New: • Our study could not confirm that children with prolonged jaundice have an increased risk of UTI. • Routine urine testing is thus not needed in otherwise healthy infants with prolonged jaundice.

  4. Bladder Diseases

    MedlinePlus

    ... frequent, urgent urination Bladder cancer Doctors diagnose bladder diseases using different tests. These include urine tests, x- ... National Institute of Diabetes and Digestive and Kidney Diseases

  5. Comparison of sodium, potassium, calcium, magnesium, zinc, copper and iron concentrations of elements in 24-h urine and spot urine in hypertensive patients with healthy renal function.

    PubMed

    Zhang, Tianjing; Chang, Xiaoyu; Liu, Wanlu; Li, Xiaoxia; Wang, Faxuan; Huang, Liping; Liao, Sha; Liu, Xiuying; Zhang, Yuhong; Zhao, Yi

    2017-12-01

    Sodium, potassium, calcium, magnesium, zinc, copper and iron are associated with the sequela of hypertension. The most reliable method for testing those elements is by collecting 24-h urine samples. However, this is cumbersome and collection of spot urine is more convenient in some circumstance. The aim of this study was to compare the concentrations of different elements in 24-h urine and spot urine. Data was collected from a sub-study of China Salt Substitute and Stroke Study. 240 participants were recruited randomly from 12 villages in two counties in Ningxia, China. Both spot and 24-h urine specimens were collected from each patient. Routine urine test was conducted, and concentration of elements was measured using microwave digestion and Inductively Coupled Plasma-Optical Emission Spectrometry. Partial correlation analysis and Spearman correlation analysis were used to investigate the concentration of different elements and the relationship between 24- h urine and spot urine. A partial correlation in sodium, potassium, calcium, magnesium and iron was found between paired 24-h urine and spot urine samples except copper and zinc: 0.430, 0.426, 0.550, 0.221 and 0.191 respectively. Spot urine can replace 24-h urine for estimating some of the elements in hypertensive patients with normal renal function. Copyright © 2017 Elsevier GmbH. All rights reserved.

  6. Albumin adsorption onto surfaces of urine collection and analysis containers☆

    PubMed Central

    Robinson, Mary K.; Caudill, Samuel P.; Koch, David D.; Ritchie, James; Hortin, Glen; Eckfeldt, John H.; Sandberg, Sverre; Williams, Desmond; Myers, Gary; Miller, W. Greg

    2017-01-01

    Background Adsorption of albumin onto urine collection and analysis containers may cause falsely low concentrations. Methods We added 125I-labeled human serum albumin to urine and to phosphate buffered solutions, incubated them with 22 plastic container materials and measured adsorption by liquid scintillation counting. Results Adsorption of urine albumin (UA) at 5–6 mg/l was <0.9%; and at 90 mg/l was <0.4%. Adsorption was generally less at pH 8 than pH 5 but only 3 cases had p <0.05. Adsorption from 11 unaltered urine samples with albumin 5–333 mg/l was <0.8%. Albumin adsorption for the material with greatest binding was extrapolated to the surface areas of 100 ml and 2 l collection containers, and to instrument sample cups and showed <1% change in concentration at 5 mg/l and <0.5% change at 20 mg/l or higher concentrations. Adsorption of albumin from phosphate buffered solutions (2–28%) was larger than that from urine. Conclusions Albumin adsorption differed among urine samples and plastic materials, but the total influence of adsorption was <1% for all materials and urine samples tested. Adsorption of albumin from phosphate buffered solutions was larger than that from urine and could be a limitation for preparations used as calibrators. PMID:24513540

  7. Temporary Urine and Brine Stowage System (TUBSS) Development

    NASA Technical Reports Server (NTRS)

    Dries, Kevin; Carrigan, Caitlin

    2011-01-01

    International Space Station (ISS) crew liquid human waste is treated with chromic and sulfuric acids to maintain stability prior to processing to recover water. This pre-treated urine (PTU) and its processed by-product, brine, are highly toxic fluids that require special containment for on-orbit stowage. The temporary urine and brine stowage syste m (TUBSS) is an assembly used to store and transfer pre-treated urine (PTU) and brine for processing or disposal at a later date. This paper describes the development of the TUBSS, including design for two-fault tolerance and materials selection to maintain a soft, collapsible container. In addition, this paper will provide results of testing as well as lessons learned from the project, culminating in the successful launch of the hardware.

  8. Bacteriuria amongst pregnant women in the Buea Health District, Cameroon: prevalence, predictors, antibiotic susceptibility patterns and diagnosis.

    PubMed

    Mokube, Morike Ngoe; Atashili, Julius; Halle-Ekane, Gregory Edie; Ikomey, George M; Ndumbe, Peter M

    2013-01-01

    Bacteriuria is associated with significant maternal and foetal risks. However, its prevalence is not known in our community. This study was carried out to determine the prevalence and predictors of bacteriuria in pregnant women of the Buea Health District (BHD) as well as the antibiotic sensitivity patterns of bacterial isolates. It also sought to determine the diagnostic performance of the nitrite and leucocyte esterase tests in detecting bacteriuria in these women. An observational analytic cross-sectional study was carried out amongst pregnant women attending selected antenatal care centres in Buea. We recruited 102 consenting pregnant women for the study. Demographic and clinical data were collected using structured questionnaires. Clean catch midstream urine was collected from each participant in sterile leak proof containers. Samples were examined biochemically, microscopically and by culture. Significant bacteriuria was defined as the presence of ≥10⁸ bacteria/L of cultured urine. Identification and susceptibility of isolates was performed using API 20E and ATB UR EU (08) (BioMerieux, Marcy l'Etoile, France). Significant bacteriuria was found in the urine of 24 of the 102 women tested giving a bacteriuria prevalence of 23.5% in pregnant women of the BHD. Asymptomatic bacteriuria was detected in 8(7.8%) of the women. There was no statistically significant predictor of bacteriuria. Escherichia coli were the most isolated (33%) uropathogens and were 100% sensitive to cefixime, cefoxitin and cephalothin. The nitrite and leucocyte esterase tests for determining bacteriuria had sensitivities of 8%, 20.8% and specificities of 98.7% and 80.8% respectively. Bacteriuria is frequent in pregnant women in the BHD suggesting the need for routine screening by urine culture. Empiric treatment with cefixime should be instituted until results of urine culture and sensitivity are available. Nitrite and leucocyte esterase tests were not sensitive enough to replace urine culture as screening tests.

  9. Comparison of Lateral Flow Assay, Kidney Inhibition Swab, and Liquid Chromatography-Tandem Mass Spectrometry for the Detection of Penicillin G Residues in Sow Urine.

    PubMed

    Shelver, Weilin L; Chakrabarty, Shubhashis; Smith, David J

    2017-03-01

    Sows (n = 126) were administered penicillin G; urine, collected at slaughter, was screened by kidney inhibition swab (KIS; 4 h testing time) and then stored at -80 °C (∼1200 days) until analysis by lateral flow assay (LF, ∼5 min testing time) and tandem quadrupole LC-MS/MS (TQ) analysis. The stability of penicillin in urine during storage was verified using TQ analyses. Quantitative results were well-correlated (R 2 = 0.98) with only a ∼10% decrease in penicillin concentration during the 3-year storage period. KIS retesting of stored samples returned results consistent with the original analyses. Lateral flow assay results were highly correlated with the KIS and TQ results. A KIS positive sample, which was not confirmed by TQ or LF, was assayed by Triple-TOF LC-MS to determine the cause of the apparent false positive. This study suggests LF can be used to quickly and efficiently screen for penicillin G residues before slaughter.

  10. Elevated urine levels of heparin-binding protein in children with urinary tract infection.

    PubMed

    Kjölvmark, Charlott; Akesson, Per; Linder, Adam

    2012-08-01

    Urinary tract infection (UTI) is a common infection diagnosis in children, and efficient diagnosis and treatment are important to avoid serious complications. In this study we investigated whether urinary levels of neutrophil-derived heparin-binding protein (HBP) can be used as a marker of UTI in children. These results were compared to those of dipstick analysis, interleukin-6 (IL-6) analysis in urine, and bacterial culturing. Seventy-eight children aged 0-18 years with fever and/or symptoms indicating UTI were enrolled in a prospective consecutive study. Urine samples were cultured and analyzed with dipstick, and concentrations of HBP and IL-6 were measured. Fifteen patients were classified as having UTI, 30 patients had fever but were diagnosed with a non-urinary tract infection, and 33 patients had neither UTI nor fever. Using a urine HBP (U-HBP) cut-off level of 32 ng/mL, the sensitivity and specificity for detecting UTI were 93.3 and 90.3 %, respectively. Receiver operating characteristic curves demonstrated that U-HBP levels were a higher specificity indicator of UTI than urine white blood cell counts or urine IL-6 levels; they also showed a higher sensitivity than the results of the urine nitrite test. All patients with significant growth of clinically relevant bacteria had elevated U-HBP levels. The results indicate that rapid analysis of U-HBP can provide helpful guidance in the management of children with suspected UTI.

  11. Urine Pretreatment History and Perspective in NASA Human Spaceflight

    NASA Technical Reports Server (NTRS)

    Anderson, Molly; Adam, Niklas; Chambers, Antja; Broyan, James

    2015-01-01

    Urine pretreatment is a technology that may seem to have small mass impacts in future spaceflight missions, but can have significant impacts on reliability, life, and performance of the rest of the wastewater management and recovery systems. NASA has experience with several different urine pretreatment systems, including those flow on the space shuttle, evaluated for NASA waste collection systems or used in Russian commodes on ISS, or developed by NASA or industry as alternatives. Each has had unique requirements for shelf life, operational life, and the life or conditions of the stored, treated urine. Each was evaluated under different test conditions depending on mission, and depending on testing experience developed over NASA's history. Those that were flown led to further lessons learned about hardware compatibility and control. As NASA looks forward to human spaceflight missions beyond low Earth orbit, these techniques need to be evaluated in new light. Based on published design reference missions, candidate requirements can be derived for future systems. Initial comparisons between these requirements and previous performance or test results can be performed. In many cases these comparisons reveal data gaps. Successful previous performance is not enough to address current needs.

  12. Do Mixed-Flora Preoperative Urine Cultures Matter?

    PubMed

    Polin, Michael R; Kawasaki, Amie; Amundsen, Cindy L; Weidner, Alison C; Siddiqui, Nazema Y

    2017-06-01

    To determine whether mixed-flora preoperative urine cultures, as compared with no-growth preoperative urine cultures, are associated with a higher prevalence of postoperative urinary tract infections (UTIs). This was a retrospective cohort study. Women who underwent urogynecologic surgery were included if their preoperative clean-catch urine culture result was mixed flora or no growth. Women were excluded if they received postoperative antibiotics for reasons other than treatment of a UTI. Women were divided into two cohorts based on preoperative urine culture results-mixed flora or no growth; the prevalence of postoperative UTI was compared between cohorts. Baseline characteristics were compared using χ 2 or Student t tests. A logistic regression analysis then was performed. We included 282 women who were predominantly postmenopausal, white, and overweight. There were many concomitant procedures; 46% underwent a midurethral sling procedure and 68% underwent pelvic organ prolapse surgery. Preoperative urine cultures resulted as mixed flora in 192 (68%) and no growth in 90 (32%) patients. Overall, 14% were treated for a UTI postoperatively. There was no difference in the proportion of patients treated for a postoperative UTI between the two cohorts (25 mixed flora vs 13 no growth, P = 0.77). These results remained when controlling for potentially confounding variables in a logistic regression model (adjusted odds ratio 0.92, 95% confidence interval 0.43-1.96). In women with mixed-flora compared with no-growth preoperative urine cultures, there were no differences in the prevalence of postoperative UTI. The clinical practice of interpreting mixed-flora cultures as negative is appropriate.

  13. Optimization of HPV DNA detection in urine by improving collection, storage, and extraction.

    PubMed

    Vorsters, A; Van den Bergh, J; Micalessi, I; Biesmans, S; Bogers, J; Hens, A; De Coster, I; Ieven, M; Van Damme, P

    2014-11-01

    The benefits of using urine for the detection of human papillomavirus (HPV) DNA have been evaluated in disease surveillance, epidemiological studies, and screening for cervical cancers in specific subgroups. HPV DNA testing in urine is being considered for important purposes, notably the monitoring of HPV vaccination in adolescent girls and young women who do not wish to have a vaginal examination. The need to optimize and standardize sampling, storage, and processing has been reported.In this paper, we examined the impact of a DNA-conservation buffer, the extraction method, and urine sampling on the detection of HPV DNA and human DNA in urine provided by 44 women with a cytologically normal but HPV DNA-positive cervical sample. Ten women provided first-void and midstream urine samples. DNA analysis was performed using real-time PCR to allow quantification of HPV and human DNA.The results showed that an optimized method for HPV DNA detection in urine should (a) prevent DNA degradation during extraction and storage, (b) recover cell-free HPV DNA in addition to cell-associated DNA, (c) process a sufficient volume of urine, and (d) use a first-void sample.In addition, we found that detectable human DNA in urine may not be a good internal control for sample validity. HPV prevalence data that are based on urine samples collected, stored, and/or processed under suboptimal conditions may underestimate infection rates.

  14. Enhanced urinalysis in the detection of asymptomatic bacteriuria in pregnancy.

    PubMed

    Aigere, E O S; Okusanya, B O; Eigbefoh, J O; Okome, G B O

    2013-01-01

    Detection and treatment of asymptomatic bacteriuria (ASB) in pregnancy is important to avert the attendant maternal and fetal morbidity. Other than urine culture, no other screening test is unequivocal. The use of enhanced urinalysis test to detect ASB in pregnancy was investigated. This was a prospective observational study which compared enhanced urinalysis with dipstick tests and urine culture. Clean catch midstream urine specimen was collected from 150 consecutive asymptomatic pregnant women. Tests of validity were used for comparison. Enhanced urinalysis detected bacteriuria as much as urine culture (4% vs. 4.7%). Itwas 57.1% sensitive and 98.6% specific. It had a false negative rate of 42.9% and was 96.7% accurate when compared to urine culture. Enhanced urinalysis took 1-2 hours to be done and required skills to use the microscope and was more expensive than dipstick urinalysis. The accuracy of enhanced urinalysis and its ability to detect ASB as much as urine culture connotes that it can be used to detect asymptomatic bacteriuria in pregnancy albeit only in secondary and tertiary health centres because of the cost and technicality involved.

  15. Frequency, predictors, and outcomes of urine drug testing among patients with advanced cancer on chronic opioid therapy at an outpatient supportive care clinic.

    PubMed

    Arthur, Joseph A; Edwards, Tonya; Lu, Zhanni; Reddy, Suresh; Hui, David; Wu, Jimin; Liu, Diane; Williams, Janet L; Bruera, Eduardo

    2016-12-01

    Data are limited on the use and outcomes of urine drug tests (UDTs) among patients with advanced cancer. The main objective of this study was to determine the factors associated with UDT ordering and results in outpatients with advanced cancer. A retrospective chart review was conducted of 1058 patients who attended an outpatient supportive care clinic from March 2014 to November 2015. Sixty-one patients who were receiving chronic opioid therapy and underwent UDTs were identified. A control group of 120 patients who did not undergo UDTs was selected for comparison. Sixty-one of 1058 patients (6%) underwent UDTs, and 33 of 61 patients (54%) had abnormal results. Multivariate analysis indicated that the odds ratio for UDT ordering was 3.9 in patients who had positive Cut Down, Annoyed, Guilty, and Eye Opener (CAGE) questionnaire results (P = .002), 4.41 in patients aged < 45 years (P < .001), 5.58 in patients who had moderate-to-severe pain (Edmonton Symptom Assessment Scale pain scores ≥4; P < .001), 0.27 in patients with advanced-stage cancer, (P = .008), and 0.25 in patients who had moderate-to-severe fatigue (P = .001). Among 52 abnormal UDT results in 33 patients, the most common opioid findings were prescribed opioids absent in urine (14 of 52 tests; 27%) and unprescribed opioids in urine (13 of 52 tests; 25%). UDTs were used infrequently among outpatients with advanced cancer who were receiving chronic opioid therapy. Younger age, positive CAGE questionnaire results, early stage cancer or no evidence of disease status, higher pain intensity, and lower fatigue scores were significant predictors of UDT ordering. More than 50% of UDT results were abnormal. More research is necessary to better characterize aberrant opioid use in patients with advanced cancer. Cancer 2016;122:3732-9. © 2016 American Cancer Society. © 2016 American Cancer Society.

  16. Prospective Evaluation of Light Scatter Technology Paired with Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry for Rapid Diagnosis of Urinary Tract Infections

    PubMed Central

    Montgomery, Sandra; Roman, Kiana; Ngyuen, Lan; Cardenas, Ana Maria; Knox, James; Tomaras, Andrew P.

    2017-01-01

    ABSTRACT Urinary tract infections are one of the most common reasons for health care visits. Diagnosis and optimal treatment often require a urine culture, which takes an average of 1.5 to 2 days from urine collection to results, delaying optimal therapy. Faster, but accurate, alternatives are needed. Light scatter technology has been proposed for several years as a rapid screening tool, whereby negative specimens are excluded from culture. A commercially available light scatter device, BacterioScan 216Dx (BacterioScan, Inc.), has recently been advertised for this application. Paired use of mass spectrometry (MS) for bacterial identification and automated-system-based susceptibility testing straight from the light scatter suspension might provide dramatic improvement in times to a result. The present study prospectively evaluated the BacterioScan device, with culture as the reference standard. Positive light scatter specimens were used for downstream rapid matrix-assisted laser desorption ionization–time of flight (MALDI-TOF) MS organism identification and automated-system-based antimicrobial susceptibility testing. Prospective evaluation of 439 urine samples showed a sensitivity of 96.5%, a specificity of 71.4%, and positive and negative predictive values of 45.1% and 98.8%, respectively. MALDI-TOF MS analysis of the suspension after density-based selection yielded a sensitivity of 72.1% and a specificity of 96.9%. Antimicrobial susceptibility testing of the samples identified by MALDI-TOF MS produced an overall categorical agreement of 99.2%. Given the high sensitivity and negative predictive value of results obtained, BacterioScan 216Dx is a reasonable approach for urine screening and might produce negative results in as few as 3 h, with no downstream workup. Paired rapid identification and susceptibility testing might be useful when MALDI-TOF MS results in an organism identification, and it might decrease the time to a result by more than 24 h. PMID:28356414

  17. Prospective Evaluation of Light Scatter Technology Paired with Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Rapid Diagnosis of Urinary Tract Infections.

    PubMed

    Montgomery, Sandra; Roman, Kiana; Ngyuen, Lan; Cardenas, Ana Maria; Knox, James; Tomaras, Andrew P; Graf, Erin H

    2017-06-01

    Urinary tract infections are one of the most common reasons for health care visits. Diagnosis and optimal treatment often require a urine culture, which takes an average of 1.5 to 2 days from urine collection to results, delaying optimal therapy. Faster, but accurate, alternatives are needed. Light scatter technology has been proposed for several years as a rapid screening tool, whereby negative specimens are excluded from culture. A commercially available light scatter device, BacterioScan 216Dx (BacterioScan, Inc.), has recently been advertised for this application. Paired use of mass spectrometry (MS) for bacterial identification and automated-system-based susceptibility testing straight from the light scatter suspension might provide dramatic improvement in times to a result. The present study prospectively evaluated the BacterioScan device, with culture as the reference standard. Positive light scatter specimens were used for downstream rapid matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) MS organism identification and automated-system-based antimicrobial susceptibility testing. Prospective evaluation of 439 urine samples showed a sensitivity of 96.5%, a specificity of 71.4%, and positive and negative predictive values of 45.1% and 98.8%, respectively. MALDI-TOF MS analysis of the suspension after density-based selection yielded a sensitivity of 72.1% and a specificity of 96.9%. Antimicrobial susceptibility testing of the samples identified by MALDI-TOF MS produced an overall categorical agreement of 99.2%. Given the high sensitivity and negative predictive value of results obtained, BacterioScan 216Dx is a reasonable approach for urine screening and might produce negative results in as few as 3 h, with no downstream workup. Paired rapid identification and susceptibility testing might be useful when MALDI-TOF MS results in an organism identification, and it might decrease the time to a result by more than 24 h. Copyright © 2017 American Society for Microbiology.

  18. Characterization of subclinical bacteriuria, bacterial cystitis, and pyelonephritis in dogs with chronic kidney disease.

    PubMed

    Foster, Jonathan D; Krishnan, Harathi; Cole, Stephen

    2018-05-15

    OBJECTIVE To determine the prevalence of bacteriuria (ie, a positive microbial culture result for ≥ 1 urine sample) in dogs with chronic kidney disease (CKD) and characterize findings of subclinical bacteriuria (SBU), bacterial cystitis, or pyelonephritis in these patients. DESIGN Retrospective, observational study. ANIMALS 182 dogs. PROCEDURES Medical records from January 2010 through July 2015 were reviewed to identify dogs with CKD that underwent urinalysis and urine microbial culture. Signalment, clinicopathologic data, stage of CKD according to previously published guidelines, results of urinalysis and urine culture, and abdominal ultrasonographic findings were recorded. Dogs with positive urine culture results were categorized as having SBU, bacterial cystitis, or pyelonephritis on the basis of these data. Prevalence of bacteriuria was calculated. Associations between CKD stage, presence of bacteriuria, and diagnosis category were analyzed statistically. RESULTS 33 of 182 (18.1%) dogs (40/235 [17.0%] urine samples) had positive culture results. All dogs received antimicrobials on the basis of culture and susceptibility test findings. Most positive culture results (18/40 [45%] samples) were found for dogs with SBU, followed by dogs with pyelonephritis (16/40 [40%]) and cystitis (6/40 [15%]). Escherichia coli was the most frequently observed isolate (29/40 [73%] cultures from 25/33 dogs). The CKD stage was not associated with presence of bacteriuria or diagnosis category. CONCLUSIONS AND CLINICAL RELEVANCE The prevalence of positive urine culture results in dogs with CKD was lower than that reported for dogs with some systemic diseases that may predispose to infection. Prospective research is needed to assess the clinical importance of SBU in dogs with CKD.

  19. Usability application of multiplex polymerase chain reaction in the diagnosis of microorganisms isolated from urine of patients treated in cancer hospital

    PubMed Central

    Cybulski, Zefiryn; Schmidt, Katarzyna; Grabiec, Alicja; Talaga, Zofia; Bociąg, Piotr; Wojciechowicz, Jacek; Roszak, Andrzej; Kycler, Witold

    2013-01-01

    Background The objective of this study was: i) to compare the results of urine culture with polymerase chain reaction (PCR) -based detection of microorganisms using two commercially available kits, ii) to assess antimicrobial susceptibility of urine isolates from cancer patients to chosen antimicrobial drugs and, if necessary, to update the recommendation of empirical therapy. Materials and methods. A one-year hospital-based prospective study has been conducted in Greater Poland Cancer Centre and Genetic Medicine Laboratory CBDNA Research Centre in 2011. Urine cultures and urine PCR assay from 72 patients were examined Results Urine cultures and urine PCR assay from 72 patients were examined. Urine samples were positive for 128 strains from which 95 (74%) were identical in both tests. The most frequently isolated bacteria in both culture and PCR assay were coliform organisms and Enterococcus spp. The Gram negative bacilli were most resistant to cotrimoxazol. 77.2% of these bacilli and 100% of E. faecalis and S. agalactiae were sensitive to amoxicillin-clavulanic acid. 4.7% of Gram positive cocci were resistant to nitrofurantoin. Conclusions The PCR method quickly finds the causative agent of urinary tract infection (UTI) and, therefore, it can help with making the choice of the proper antimicrobial therapy at an early stage. It appears to be a viable alternative to the recommendations made in general treatment guidelines, in cases where diversified sensitivity patterns of microorganisms have been found. PMID:24133395

  20. Performance evaluation of three on-site adulterant detection devices for urine specimens.

    PubMed

    Peace, Michelle R; Tarnai, Lisa D

    2002-10-01

    The performance of three on-site adulterant detection devices that assess the integrity of urine specimens collected for drug-of-abuse testing was evaluated: the Intect 7, MASK Ultra Screen, and Adultacheck 4. Intect 7 simultaneously tests creatinine, nitrite, glutaraldehyde, pH, specific gravity, and the presence of bleach and pyridinium chlorochromate (PCC). Mask Ultra Screen tests creatinine, nitrite, pH, specific gravity, and oxidants, and Adultacheck 4 tests creatinine, nitrite, glutaraldehyde, and pH. Urine specimens were prepared with the Substance Abuse and Mental Health Administration regulated analytes at 50% above the cut-off concentrations. Stealth, Urine Luck, Instant Clean ADD-IT-ive, and KLEAR were added individually to the drug-added urine specimens so that their concentrations reflected the "optimum" usage reported in their package inserts and 25% above and below that optimum. Stealth is reported to be peroxidase; Urine Luck is believed to be PCC; Instant Clean ADD-it-ive reportedly contains glutaraldehyde, and Klear is a nitrite. The following diluents/adulterants were added at 25%, 33%, and 50% of the volume of drug-added urine: distilled water, bleach, ammonia, and vinegar. Of the devices tested, Intect 7 proved to be the most sensitive, and it correctly indicated the presence of adulterant or diluent in all samples tested. In order to do so, all indication pads had to be assessed in concert. Adultacheck 4 specifically assesses four characteristics of urine integrity and is therefore very limited in detecting the use of several popular adulterants that are commercially available. Although it correctly assessed the four characteristics, it did not detect the use of Stealth, Urine Luck, or Instant Clean ADD-it-ive. Mask Ultra Screen can potentially detect a broader range of adulterants than Adultacheck 4. However, in practice, it only detected them at levels well above their optimum usage, making it less efficacious than Intect 7. Clearly, the specific identification of an adulterant is a trade-off for sensitive detection of several adulterants.

  1. Performance assessment of urine flow cytometry (UFC) to screen urines to reflex to culture in immunocompetent and immunosuppressed hosts.

    PubMed

    Stefanovic, Aleksandra; Roscoe, Diane; Ranasinghe, Romali; Wong, Titus; Bryce, Elizabeth; Porter, Charlene; Lim, Adelina; Grant, Jennifer; Ng, Karen; Pudek, Morris

    2017-09-01

    Urine flow cytometry (UFC) is an automated method to quantify bacterial and white blood cell (WBC) counts. We aimed to determine whether a threshold for these parameters can be set to use UFC as a sensitive screen to predict which urine samples will subsequently grow in culture. Urines submitted to our microbiology laboratory at a tertiary care centre from 22 July 2015-17 February 2016 underwent UFC (Sysmex UF-1000i) analysis, regular urinalysis and urine culture. Positive urine cultures were defined as growth ≥104 c.f.u. ml-1 of organisms associated with urinary tract infections. The correlation of UFC bacterial and WBC counts with urine culture was assessed using receiver operating characteristics curves. The sensitivity (SN), specificity (SP), negative predictive values (NPVs), positive predictive values (PPVs) and false negative rate (FNR) were calculated at various thresholds in immunocompetent and immunosuppressed patients. A total of 15 046 urine specimens were submitted, of which 14 908 were analysable in the study. The average time to UFC result from receipt in the laboratory was 0.76 h (+/-1.04). The test performance at a set threshold of UFC bacteria ≥20 or WBC >5 was: SN=96.0 %, SP=39.2 %, PPV=47.0 %, NPV=94.5 % and FNR=4.0 %. This threshold eliminates 26 % of urine cultures. Immunosuppressed hosts had a lower sensitivity of 90.6 % and a higher FNR of 9.4 %. UFC is a rapid and sensitive method to screen out urine samples that will subsequently be negative and to reflex urines to culture that will subsequently grow. UFC results are available within 1 h from receipt and enable the elimination of culture when the set threshold is not met.

  2. A three-gene panel on urine increases PSA specificity in the detection of prostate cancer.

    PubMed

    Rigau, Marina; Ortega, Israel; Mir, Maria Carmen; Ballesteros, Carlos; Garcia, Marta; Llauradó, Marta; Colás, Eva; Pedrola, Núria; Montes, Melania; Sequeiros, Tamara; Ertekin, Tugce; Majem, Blanca; Planas, Jacques; Ruiz, Anna; Abal, Miguel; Sánchez, Alex; Morote, Juan; Reventós, Jaume; Doll, Andreas

    2011-12-01

    Several studies have demonstrated the usefulness of monitoring an RNA transcript, such as PCA3, in post-prostate massage (PM) urine for increasing the specificity of prostate-specific antigen (PSA) in the detection of prostate cancer (PCa). However, a single marker may not necessarily reflect the multifactorial nature of PCa. We analyzed post-PM urine samples from 154 consecutive patients, who presented for prostate biopsies because of elevated serum PSA (>4 ng/ml) and/or abnormal digital rectal exam. We tested whether the putative PCa biomarkers PSMA, PSGR, and PCA3 could be detected by quantitative real-time PCR in post-PM urine sediment. We combined these findings to test if a combination of these biomarkers could improve the specificity of actual diagnosis. Afterwards, we specifically tested our model for clinical usefulness in the PSA diagnostic "gray zone" (4-10 ng/ml) on a target subset of 82 men with no prior biopsy. By univariate analysis, we found that the PSMA, PSGR, and PCA3 scores were significant predictors of PCa. Using a multiplex model, the area under the multi receiver-operating characteristic curve was 0.74 versus 0.82 in the diagnostic "gray zone." Fixing the sensitivity at 96%, we obtained a specificity of 34% and 50% in the gray zone. Taken together, these results provide a strategy for the development of a more accurate model for PCa diagnosis. In the future, a multiplexed, urine-based diagnostic test for PCa with a higher specificity, but the same sensitivity as the serum-PSA test, could be used to determine better which patients should undergo biopsy. Copyright © 2011 Wiley Periodicals, Inc.

  3. Dual Fan Separator within the Universal Waste Management System

    NASA Technical Reports Server (NTRS)

    Stapleton, Tom; Converse, Dave; Broyan, James Lee, Jr.

    2014-01-01

    Since NASA's new spacecraft in development for both LEO and Deep Space capability have considerable crew volume reduction in comparison to the Space Shuttle, it is clear that NASA requires a smaller and less expensive commode. The UTAS Universal Waste Management System (UWMS) was designed to address these new constraints, resulting in an 80% volume reduction in the cabin while enhancing performance. Whereas all of the current space commodes use air flow to capture both urine and feces and separate air from the captured air/urine mixture, the UWMS commode and urine fans and the urine separator were combined into a single unit. This unit enables use of a single motor and motor controller, which provides considerable packaging and weight efficiency. In some of the intended platform applications for the UWMS, the urine is pumped to a water reclamation system. The ISS Urine Processor Assembly (UPA) system requires delivered urine to include less than 0.25% air inclusion. Air inclusion in centrifugal urine separators is greatly dependent on its rotational speed. To satisfy this requirement, a gear reducer was included, allowing the fans to rotate at a much higher speed than the separator. This new design, the Dual Fan Separator (DFS) has been designed, prototyped and tested. This paper will outline the studies and analysis performed to develop the design configuration for testing. The studies included a configuration trade study, dynamic stability analysis of the rotating bodies and a performance analysis of included labyrinth seals. NASA is considereing a program to fly the UWMS aboard the ISS as a flight experiment. The goal of the design activity is to elevate the Technical Readiness Level (TRL) of the Dual Fan Separator and determine if the concept is ready to be included in flight experiment deliverable.

  4. Serum and urine metabolomic fingerprinting in diagnostics of inflammatory bowel diseases.

    PubMed

    Dawiskiba, Tomasz; Deja, Stanisław; Mulak, Agata; Ząbek, Adam; Jawień, Ewa; Pawełka, Dorota; Banasik, Mirosław; Mastalerz-Migas, Agnieszka; Balcerzak, Waldemar; Kaliszewski, Krzysztof; Skóra, Jan; Barć, Piotr; Korta, Krzysztof; Pormańczuk, Kornel; Szyber, Przemyslaw; Litarski, Adam; Młynarz, Piotr

    2014-01-07

    To evaluate the utility of serum and urine metabolomic analysis in diagnosing and monitoring of inflammatory bowel diseases (IBD). Serum and urine samples were collected from 24 patients with ulcerative colitis (UC), 19 patients with the Crohn's disease (CD) and 17 healthy controls. The activity of UC was assessed with the Simple Clinical Colitis Activity Index, while the activity of CD was determined using the Harvey-Bradshaw Index. The analysis of serum and urine samples was performed using proton nuclear magnetic resonance (NMR) spectroscopy. All spectra were exported to Matlab for preprocessing which resulted in two data matrixes for serum and urine. Prior to the chemometric analysis, both data sets were unit variance scaled. The differences in metabolite fingerprints were assessed using partial least-squares-discriminant analysis (PLS-DA). Receiver operating characteristic curves and area under curves were used to evaluate the quality and prediction performance of the obtained PLS-DA models. Metabolites responsible for separation in models were tested using STATISTICA 10 with the Mann-Whitney-Wilcoxon test and the Student's t test (α = 0.05). The comparison between the group of patients with active IBD and the group with IBD in remission provided good PLS-DA models (P value 0.002 for serum and 0.003 for urine). The metabolites that allowed to distinguish these groups were: N-acetylated compounds and phenylalanine (up-regulated in serum), low-density lipoproteins and very low-density lipoproteins (decreased in serum) as well as glycine (increased in urine) and acetoacetate (decreased in urine). The significant differences in metabolomic profiles were also found between the group of patients with active IBD and healthy control subjects providing the PLS-DA models with a very good separation (P value < 0.001 for serum and 0.003 for urine). The metabolites that were found to be the strongest biomarkers included in this case: leucine, isoleucine, 3-hydroxybutyric acid, N-acetylated compounds, acetoacetate, glycine, phenylalanine and lactate (increased in serum), creatine, dimethyl sulfone, histidine, choline and its derivatives (decreased in serum), as well as citrate, hippurate, trigonelline, taurine, succinate and 2-hydroxyisobutyrate (decreased in urine). No clear separation in PLS-DA models was found between CD and UC patients based on the analysis of serum and urine samples, although one metabolite (formate) in univariate statistical analysis was significantly lower in serum of patients with active CD, and two metabolites (alanine and N-acetylated compounds) were significantly higher in serum of patients with CD when comparing jointly patients in the remission and active phase of the diseases. Contrary to the results obtained from the serum samples, the analysis of urine samples allowed to distinguish patients with IBD in remission from healthy control subjects. The metabolites of importance included in this case up-regulated acetoacetate and down-regulated citrate, hippurate, taurine, succinate, glycine, alanine and formate. NMR-based metabolomic fingerprinting of serum and urine has the potential to be a useful tool in distinguishing patients with active IBD from those in remission.

  5. Lupus Nephritis

    MedlinePlus

    ... can be a sign of lupus nephritis. What tests do health care professionals use to diagnose lupus nephritis? Lupus nephritis ... and blood tests and a kidney biopsy. Urine Test Your health care professional uses a urine sample to look for ...

  6. Fluorescence And Alternative Methods In Urine Drug Testing

    NASA Astrophysics Data System (ADS)

    Jain, Naresh C.

    1988-04-01

    Drug abuse has become-one of the most compelling realities _ ot contemporary society. It has penetrated every segment ot our population: trom schools to sports and trom organized crime to board rooms . Drugs in tie w9rkplace allegedly cost government agencies and business millions ot dollars each year in increased absenteeism,. poor work performance, thefts,accidents andwastedtime. The President's Commission on Organized Crime and the federal government are in tavor ot urine drug testing. In fact many employers are now resorting to urine drug testing on current and prospective employees. This presep.tation discusses different laboratory methods used in urine drug.testing, including immunoassays, fluorescence polarization, thin layer chromatography, high pressure liquid chromatography, gas chromatography and gas-chromatography-mass spectrometry.

  7. Development of an Inline Urine Monitoring System for the International Space Station

    NASA Technical Reports Server (NTRS)

    Broyan, James Lee, Jr.; Cibuzar, Banelle R.

    2008-01-01

    Human exposure to microgravity during spaceflight causes bone loss. Calcium and other metabolic byproducts are excreted in urine voids. Frequent and accurate measurement of urine void volume and constituents is essential to determining crew bone loss and the effectiveness of countermeasures. Previous US Space Shuttle (SS) Urine Monitoring System (UMS) technology was unable to accurately measure urine void volumes due to cross contamination between users and fluid system instabilities. Currently, urine voids must be collected manually in a flexible plastic bag containing a known tracer quantity. The crew member must completely mix the bag then withdraw a representative syringe sample for later ground analysis. The current bag system accuracy is highly dependent on mixing technique. The International Space Station (ISS) UMS has been developed as an automated device that collects urine from the Waste and Hygiene Compartment (WHC) urinal funnel interface, separates the urine, measures the void volume, and allows for syringe sampling. After operations, the ISS UMS delivers the urine to the WHC for normal processing then flushes its plumbing with a small water volume. The current ISS UMS design incorporates an innovative rotary separator that minimizes foaming, greatly reduces cross contamination between urine voids (< 0.5 ml urine), and provides accurate volume measurements (< +/- 2% error for 100 to 1000 ml void volumes). The system performance has been validated with extensive ground tests and reduced gravity aircraft flights. The lockersized ISS UMS is currently being modified to interface with the ISS Node 3 WHC Russian ACY hardware. The operation principles, characteristics, and results are outlined in the paper.

  8. Amylase - urine

    MedlinePlus

    ... page: //medlineplus.gov/ency/article/003607.htm Amylase - urine To use the sharing features on this page, ... test that measures the amount of amylase in urine. Amylase is an enzyme that helps digest carbohydrates. ...

  9. Using response-time latencies to measure athletes’ doping attitudes: the brief implicit attitude test identifies substance abuse in bodybuilders

    PubMed Central

    2014-01-01

    Background Knowing and, if necessary, altering competitive athletes’ real attitudes towards the use of banned performance-enhancing substances is an important goal of worldwide doping prevention efforts. However athletes will not always be willing to reporting their real opinions. Reaction time-based attitude tests help conceal the ultimate goal of measurement from the participant and impede strategic answering. This study investigated how well a reaction time-based attitude test discriminated between athletes who were doping and those who were not. We investigated whether athletes whose urine samples were positive for at least one banned substance (dopers) evaluated doping more favorably than clean athletes (non-dopers). Methods We approached a group of 61 male competitive bodybuilders and collected urine samples for biochemical testing. The pictorial doping Brief Implicit Association Test (BIAT) was used for attitude measurement. This test quantifies the difference in response latencies (in milliseconds) to stimuli representing related concepts (i.e. doping–dislike/like–[health food]). Results Prohibited substances were found in 43% of all tested urine samples. Dopers had more lenient attitudes to doping than non-dopers (Hedges’s g = -0.76). D-scores greater than -0.57 (CI95 = -0.72 to -0.46) might be indicative of a rather lenient attitude to doping. In urine samples evidence of administration of combinations of substances, complementary administration of substances to treat side effects and use of stimulants to promote loss of body fat was common. Conclusion This study demonstrates that athletes’ attitudes to doping can be assessed indirectly with a reaction time-based test, and that their attitudes are related to their behavior. Although bodybuilders may be more willing to reveal their attitude to doping than other athletes, these results still provide evidence that the pictorial doping BIAT may be useful in athletes from other sports, perhaps as a complementary measure in evaluations of the effectiveness of doping prevention interventions. PMID:25209168

  10. Clinical utility of routine laboratory testing to identify possible secondary causes in older men with osteoporosis: the Osteoporotic Fractures in Men (MrOS) Study

    PubMed Central

    Fink, Howard A.; Litwack-Harrison, Stephanie; Taylor, Brent C.; Bauer, Douglas C.; Orwoll, Eric S.; Lee, Christine G.; Barrett-Connor, Elizabeth; Schousboe, John T.; Kado, Deborah M.; Garimella, Pranav S.; Ensrud, Kristine E.

    2016-01-01

    Purpose To evaluate the utility of recommended laboratory testing to identify secondary causes in older men with osteoporosis, we examined prevalence of laboratory abnormalities in older men with and without osteoporosis. Methods 1572 men aged ≥65 years in the Osteoporotic Fractures in Men study completed bone mineral density (BMD) testing and a battery of laboratory measures, including serum calcium, phosphorus, alkaline phosphatase, parathyroid hormone (PTH), thyroid-stimulating hormone (TSH), 25-OH vitamin D, total testosterone, spot urine calcium/creatinine ratio, spot urine albumin-creatinine ratio, creatinine-derived estimate glomerular filtration rate, 24-hour urine calcium, and 24-hour urine free cortisol. Using cross-sectional analyses, we calculated prevalence ratios (PR) and 95% confidence intervals (CI) for the association of any and specific laboratory abnormalities with osteoporosis, and the number of men with osteoporosis needed to test to identify one additional laboratory abnormality compared to testing men without osteoporosis. Results Approximately 60% of men had ≥1 laboratory abnormality in both men with and without osteoporosis. Among individual tests, only vitamin D insufficiency (PR, 1.13; 95% CI, 1.05–1.22) and high alkaline phosphatase (PR, 3.05; 95% CI, 1.52–6.11) were more likely in men with osteoporosis. Hypercortisolism and hyperthyroidism were uncommon and not significantly more frequent in men with osteoporosis. No osteoporotic men had hypercalciuria. Conclusions Though most of these older men had ≥1 laboratory abnormality, few routinely recommended individual tests were more common in men with osteoporosis than in those without osteoporosis. Possibly excepting vitamin D and alkaline phosphatase, benefit of routine laboratory testing to identify possible secondary causes in older osteoporotic men appears low. Results may not be generalizable to younger men or to older men in whom history and exam findings raise clinical suspicion for a secondary cause of osteoporosis. PMID:26458388

  11. The Efficacy of Contingency Management on Cocaine Craving, using Prize-based Reinforcement of Abstinence in Cocaine Users.

    PubMed

    Pirnia, Bijan; Tabatabaei, Seyed Kazem Rasoulzadeh; Tavallaii, Abbas; Soleimani, Ali Akbar; Pirnia, Kambiz

    2016-11-01

    Contingency management (CM) is one of the most common therapies in the domain of drug addiction. This study has been carried out with the purpose of evaluating the efficacy of contingency management intervention. In an experimental design, between December 15, 2014 and November 20, 2015, fifty men (between 18 and 31 with an average age of 24.6) with a history of cocaine use, were selected voluntarily and were randomly assigned into two groups of CM and control group. The CM group were awarded coupons for negative urine tests, over a period of twelve weeks. The urine tests were taken from the participants twice per week, with cutoff concentrations for positive set at 300 ng/ml and self-reporting index of cocaine craving (response rate = 96%) were evaluated in two phase, through pretest and posttest measures. The data were analyzed by parametric covariance test. Additionally, the qualitative data, resulted from demographic measures, were coded and were analyzed with the help of an analysis instrument of qualitative data i.e. ATLAS.ti-5.2. The primary outcome was the number of negative urine tests and the secondary outcome included the cocaine usage craving index over twelve weeks. The mean of (95% of confidence) number of negative cocaine urine tests was 15.4 (13.1-17.8) in the CM group and 19.7 (17.7-21.6) in the control group (P = 0.049). Also, results showed that CM has a significant effect on reducing craving (p<0.01). The findings of this study, while having practical aspects in this domain, can be valuable in planning remedial procedures.

  12. Can the Griess Nitrite Test and a Urinary Pus Cell Count of ≥5 Cells Per Micro Litre of Urine in Pregnant Women be Used for the Screening or the Early Detection of Urinary Tract Infections in Rural India?

    PubMed

    Thakre, Sushama S; Dhakne, Supriya S; Thakre, Subhash B; Thakre, Amol D; Ughade, Suresh M; Kale, Priya

    2012-11-01

    Urinary Tract Infection (UTI) is a common problem in pregnancy due to the morphological and the physiological changes that take place in the genitourinary tract during pregnancy. Screening methods may be useful, because a full bacteriological analysis could be reserved for those patients who are symptomatic or those who have positive screening test results. The exact prevalence of UTI in rural, pregnant women is unknown. The present study was undertaken to estimate the prevalence of UTI in pregnant women and for ascertaining the utility of the Griess Nitrite test and the Urinary Pus Cell Count of ≥5 cells per micro litre test for the screening or the early detection of UTI in them at primary health care clinics. Occurrence of urinary complaints was compared in UTI and non UTI women. We conducted a study on 300 randomly selected, pregnant women from rural areas. Urine cultures, pus-cell counts and the Griess nitrite test were used for diagnosis of UTI. The screening tests for UTI were evaluated in terms of their sensitivity, specificity, Positive Predictive Value (PPV), Negative Predictive Value (NPV) and the percentage of correctly classified. In the present study, the prevalence of UTI was found to be 29/300 (9.6%, 95% confidence interval 9.57-9.63). The specificities of the two screening tests were comparable (97.05% and 94.47%). Also, the negative predictive values of the two tests were almost similar (97.77% and 96.96%). The percentage of correctly classified by the Griess nitrite test and the urine pus cell count were found to be 95.33% and 92.33% respectively. The proportion of the women with various urinary complaints was significantly higher (P<0.00) in the UTI subjects as compared to that in the non-UTI subjects. Urine culture remains the gold standard for the detection of asymptomatic bacteriuria. The Nitrite test of uncentrifuged urine was observed to be the best among the screening tests which were evaluated in terms of their efficiency and validity.

  13. High performance of a new PCR-based urine assay for HPV-DNA detection and genotyping.

    PubMed

    Tanzi, Elisabetta; Bianchi, Silvia; Fasolo, Maria Michela; Frati, Elena R; Mazza, Francesca; Martinelli, Marianna; Colzani, Daniela; Beretta, Rosangela; Zappa, Alessandra; Orlando, Giovanna

    2013-01-01

    Human papillomavirus (HPV) testing has been proposed as a means of replacing or supporting conventional cervical screening (Pap test). However, both methods require the collection of cervical samples. Urine sample is easier and more acceptable to collect and could be helpful in facilitating cervical cancer screening. The aim of this study was to evaluate the sensitivity and specificity of urine testing compared to conventional cervical smear testing using a PCR-based method with a new, designed specifically primer set. Paired cervical and first voided urine samples collected from 107 women infected with HIV were subjected to HPV-DNA detection and genotyping using a PCR-based assay and a restriction fragment length polymorphism method. Sensitivity, specificity, Positive Predictive Value (PPV), and Negative Predictive Value (NPV) were calculated using the McNemar's test for differences. Concordance between tests was assessed using the Cohen's unweighted Kappa (k). HPV DNA was detected in 64.5% (95% CI: 55.1-73.1%) of both cytobrush and urine samples. High concordance rates of HPV-DNA detection (k = 0.96; 95% CI: 0.90-1.0) and of high risk-clade and low-risk genotyping in paired samples (k = 0.80; 95% CI: 0.67-0.92 and k = 0.74; 95% CI: 0.60-0.88, respectively) were observed. HPV-DNA detection in urine versus cervix testing revealed a sensitivity of 98.6% (95% CI: 93.1-99.9%) and a specificity of 97.4% (95% CI: 87.7-99.9%), with a very high NPV (97.4%; 95% CI: 87.7-99.9%). The PCR-based assay utilized in this study proved highly sensitive and specific for HPV-DNA detection and genotyping in urine samples. These data suggest that a urine-based assay would be a suitable and effective tool for epidemiological surveillance and, most of all, screening programs. Copyright © 2012 Wiley Periodicals, Inc.

  14. The Diagnostic Accuracy of Urine-Based Xpert MTB/RIF in HIV-Infected Hospitalized Patients Who Are Smear-Negative or Sputum Scarce

    PubMed Central

    Peter, Jonathan G.; Theron, Grant; Muchinga, Tapuwa E.; Govender, Ureshnie; Dheda, Keertan

    2012-01-01

    Background Hospitals in sub-Saharan Africa are inundated with HIV-infected patients and tuberculosis (TB) is the commonest opportunistic infection in this sub-group. Up to one third of TB-HIV co-infected patients fail to produce a sputum sample (sputum scarce) and diagnosis is thus often delayed or missed. We investigated the sensitivity of urine-based methods (Xpert MTB/RIF, LAM strip test and LAM ELISA) in such patients. Methodology/Principal Findings 281 HIV-infected hospitalised patients with clinically suspected TB provided a spot urine sample. The reference standard was culture positivity for Mycobacterium tuberculosis on ≥1 sputum or extra-pulmonary sample. MTB/RIF was performed using 1 ml of both unprocessed and, when possible, concentrated urine. Each unconcentrated urine sample was also tested using the Clearview LAM ELISA and Alere LAM strip test. 42% (116/242) of patients had culture-proven TB. 18% (20/54) were sputum scarce. In sputum-scarce patients, the sensitivity of urine MTB/RIF and LAM ELISA was 40% (95%CI: 22–61) and 60% (95%CI: 39–78), respectively. Urine MTB/RIF specificity was 98% (95%CI: 95–100). Combined sensitivity of urine LAM ELISA and MTB/RIF was better than MTB/RIF alone [MTB/RIF and LAM: 70% (95%CI: 48–85) vs. MTB/RIF: 40% (95%CI: 22–61), p = 0.03]. Significant predictors of urine MTB/RIF positivity were CD4<50 cells/ml (p = 0.001), elevated protein-to-creatinine ratio (p<0.001) and LAM ELISA positivity (p<0.001). Urine centrifugation and pelleting significantly increased the sensitivity of MTB/RIF over unprocessed urine in paired samples [42% (95%CI: 26–58) vs. 8% (95%CI: 0–16), p<0.001]. Urine MTB/RIF-generated CT values correlated poorly with markers of bacillary burden (smear grade and time-to-positivity). Conclusions/Significance This preliminary study indicates that urine-based MTB/RIF, alone or in combination with LAM antigen detection, may potentially aid the diagnosis of TB in HIV-infected patients with advanced immunosuppression when sputum-based diagnosis is not possible. Concentration of urine prior to MTB/RIF-testing significantly improves sensitivity. PMID:22815718

  15. Evaluation and Comparison of Multiple Test Methods, Including Real-time PCR, for Legionella Detection in Clinical Specimens

    PubMed Central

    Peci, Adriana; Winter, Anne-Luise; Gubbay, Jonathan B.

    2016-01-01

    Legionella is a Gram-negative bacterium that can cause Pontiac fever, a mild upper respiratory infection and Legionnaire’s disease, a more severe illness. We aimed to compare the performance of urine antigen, culture, and polymerase chain reaction (PCR) test methods and to determine if sputum is an acceptable alternative to the use of more invasive bronchoalveolar lavage (BAL). Data for this study included specimens tested for Legionella at Public Health Ontario Laboratories from 1st January, 2010 to 30th April, 2014, as part of routine clinical testing. We found sensitivity of urinary antigen test (UAT) compared to culture to be 87%, specificity 94.7%, positive predictive value (PPV) 63.8%, and negative predictive value (NPV) 98.5%. Sensitivity of UAT compared to PCR was 74.7%, specificity 98.3%, PPV 77.7%, and NPV 98.1%. Out of 146 patients who had a Legionella-positive result by PCR, only 66 (45.2%) also had a positive result by culture. Sensitivity for culture was the same using either sputum or BAL (13.6%); sensitivity for PCR was 10.3% for sputum and 12.8% for BAL. Both sputum and BAL yield similar results regardless testing methods (Fisher Exact p-values = 1.0, for each test). In summary, all test methods have inherent weaknesses in identifying Legionella; therefore, more than one testing method should be used. Obtaining a single specimen type from patients with pneumonia limits the ability to diagnose Legionella, particularly when urine is the specimen type submitted. Given ease of collection and similar sensitivity to BAL, clinicians are encouraged to submit sputum in addition to urine when BAL submission is not practical from patients being tested for Legionella. PMID:27630979

  16. Comparison of urine specific gravity values from total-solids refractometry and reagent strip method.

    PubMed

    Chatasingh, S; Tapaneya-Olarn, W

    1989-01-01

    The comparison of specific gravity values of 561 urine samples from TS meter and reagent strip was made. The data were divided into two groups: group 1-less than 2+ protein contained urine samples and group 2--equal or more than 2+ protein contained urine samples. The results revealed that the specific gravity values from both methods in both groups were statistically different (p less than 0.01) but they were correlated at r = 0.84 (p less than 0.001) and r = 0.73 (p less than 0.001) in group 1 and group 2, respectively. It was concluded that the reagent strip is suitable for use as a screening test but it should not be considered when precise measurement is necessary.

  17. Statistical analysis of Skylab 3. [endocrine/metabolic studies of astronauts

    NASA Technical Reports Server (NTRS)

    Johnston, D. A.

    1974-01-01

    The results of endocrine/metabolic studies of astronauts on Skylab 3 are reported. One-way analysis of variance, contrasts, two-way unbalanced analysis of variance, and analysis of periodic changes in flight are included. Results for blood tests, and urine tests are presented.

  18. First-void urine: A potential biomarker source for triage of high-risk human papillomavirus infected women.

    PubMed

    Van Keer, Severien; Pattyn, Jade; Tjalma, Wiebren A A; Van Ostade, Xaveer; Ieven, Margareta; Van Damme, Pierre; Vorsters, Alex

    2017-09-01

    Great interest has been directed towards the use of first-void urine as a liquid biopsy for high-risk human papillomavirus DNA testing. Despite the high correlations established between urinary and cervical infections, human papillomavirus testing is unable to distinguish between productive and transforming high-risk infections that have the tendency to progress to cervical cancer. Thus far, investigations have been primarily confined to the identification of biomarkers for triage of high-risk human papillomavirus-positive women in cervicovaginal specimens and tissue biopsies. This paper reviews urinary biomarkers for cervical cancer and triage of high-risk human papillomavirus infections and elaborates on the opportunities and challenges that have emerged regarding the use of first-void urine as a liquid biopsy for the analysis of both morphological- (conventional cytology and novel immunohistochemical techniques) and molecular-based (HPV16/18 genotyping, host/viral gene methylation, RNA, and proteins) biomarkers. A literature search was performed in PubMed and Web of Science for studies investigating the use of urine as a biomarker source for cervical cancer screening. Five studies were identified reporting on biomarkers that are still in preclinical exploratory or clinical assay development phases and on assessments of non-invasive (urine) samples. Although large-scale validation studies are still needed, we conclude that methylation of both host and viral genes in urine has been proven feasible for use as a molecular cervical cancer triage and screening biomarker in phase two studies. This is especially promising and underscores our hypothesis that human papillomavirus DNA and candidate human and viral biomarkers are washed away with the initial, first-void urine, together with exfoliated cells, debris and impurities that line the urethra opening. Similar to the limitations of self-collected cervicovaginal samples, first-void urine will likely not fulfil the high-quality cellularity standards required for morphological biomarkers. Molecular biomarkers will likely overcome this issue to yield high-throughput, objective, and reproducible results. When using proper sampling, transport, storage, preanalytical biomarker concentration techniques, and clinically validated assays, first-void urine is expected to be a valuable source of molecular biomarkers for cervical cancer screening. Furthermore, as first-void urine can be easily and non-invasively collected, it is a highly preferred technique among women and offers the ability to test both primary high-risk human papillomavirus and biomarkers in the same sample. In addition, the use of first-void urine confers opportunities to reduce loss-to follow-up and non-adherence to screening subjects. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  19. Application of drug testing using exhaled breath for compliance monitoring of drug addicts in treatment.

    PubMed

    Carlsson, Sten; Olsson, Robert; Lindkvist, Irene; Beck, Olof

    2015-04-01

    Exhaled breath has recently been identified as a possible matrix for drug testing. This study explored the potential of this new method for compliance monitoring of patients being treated for dependence disorders. Outpatients in treatment programs were recruited for this study. Urine was collected as part of clinical routine and a breath sample was collected in parallel together with a questionnaire about their views of the testing procedure. Urine was analyzed for amphetamines, benzodiazepines, cannabis, cocaine, buprenorphine, methadone and opiates using CEDIA immunochemical screening and mass spectrometry confirmation. The exhaled breath was collected using the SensAbues device and analyzed by mass spectrometry for amphetamine, methamphetamine, diazepam, oxazepam, tetrahydrocannabinol, cocaine, benzoylecgonine, buprenorphine, methadone, morphine, codeine and 6-acetylmorphine. A total of 122 cases with parallel urine and breath samples were collected; 34 of these were negative both in urine and breath. Out of 88 cases with positive urine samples 51 (58%) were also positive in breath. Among the patients on methadone treatment, all were positive for methadone in urine and 83% were positive in breath. Among patients in treatment with buprenorphine, 92% were positive in urine and among those 80% were also positive in breath. The questionnaire response documented that in general, patients accepted drug testing well and that the breath sampling procedure was preferred. Compliance testing for the intake of prescribed and unprescribed drugs among patients in treatment for dependence disorders using the exhaled breath sampling technique is a viable method and deserves future attention.

  20. Deep Sequencing of Urinary RNAs for Bladder Cancer Molecular Diagnostics.

    PubMed

    Sin, Mandy L Y; Mach, Kathleen E; Sinha, Rahul; Wu, Fan; Trivedi, Dharati R; Altobelli, Emanuela; Jensen, Kristin C; Sahoo, Debashis; Lu, Ying; Liao, Joseph C

    2017-07-15

    Purpose: The majority of bladder cancer patients present with localized disease and are managed by transurethral resection. However, the high rate of recurrence necessitates lifetime cystoscopic surveillance. Developing a sensitive and specific urine-based test would significantly improve bladder cancer screening, detection, and surveillance. Experimental Design: RNA-seq was used for biomarker discovery to directly assess the gene expression profile of exfoliated urothelial cells in urine derived from bladder cancer patients ( n = 13) and controls ( n = 10). Eight bladder cancer specific and 3 reference genes identified by RNA-seq were quantitated by qPCR in a training cohort of 102 urine samples. A diagnostic model based on the training cohort was constructed using multiple logistic regression. The model was further validated in an independent cohort of 101 urines. Results: A total of 418 genes were found to be differentially expressed between bladder cancer and controls. Validation of a subset of these genes was used to construct an equation for computing a probability of bladder cancer score (P BC ) based on expression of three markers ( ROBO1, WNT5A , and CDC42BPB ). Setting P BC = 0.45 as the cutoff for a positive test, urine testing using the three-marker panel had overall 88% sensitivity and 92% specificity in the training cohort. The accuracy of the three-marker panel in the independent validation cohort yielded an AUC of 0.87 and overall 83% sensitivity and 89% specificity. Conclusions: Urine-based molecular diagnostics using this three-marker signature could provide a valuable adjunct to cystoscopy and may lead to a reduction of unnecessary procedures for bladder cancer diagnosis. Clin Cancer Res; 23(14); 3700-10. ©2017 AACR . ©2017 American Association for Cancer Research.

  1. Trace Urine Albumin and Mortality: Kangbuk Samsung Health Study.

    PubMed

    Han, Eun Na; Lee, Kyu Beck; Kim, Hyang; Hyun, Young Youl

    2018-06-07

    The importance of a trace albumin on the urine dipstick test is not well known and is frequently disregarded in clinical practice. The aim of this study is to investigate the role of trace albuminuria in predicting all-cause mortality in Korean adults. In this retrospective cohort study, we analyzed 347,938 Korean adults who underwent urine dipstick test from 2002 to 2012 in a health examination program. The participants were divided into three groups according to dipstick negative, trace (±), and overt (≥1+) albuminuria. The trace group was further stratified by urine specific gravity (SG) and classified as either high (≥1.020) or low (≤1.015) SG. Mortality data was obtained from STATICS KOREA, a Korean federal statistical organization. During a median follow-up period of 5.9 years, 1,855 deaths occurred. Mortality was compared to negative group and adjusted for potential risk factors. Mortality did not increase in the trace group (HR, 1.19; 95% CI, 0.97-1.47; P=0.097), but increased in the overt (HR, 1.69; 95% CI, 1.38-2.07; P< 0.001) albuminuria group. When the trace group was subdivided according to urine SG, mortality did not increase in the high SG (HR, 1.09; 95% CI, 0.86-1.37; P=0.488) group, but increased in the low SG (HR, 1.84; 95% CI, 1.19-2.83; P=0.006) and overt (HR, 1.70; 95% CI, 1.39-2.08; P< 0.001) groups. Trace albumin with low SG in urine dipstick test was associated with higher all-cause mortality in Korean adults. We should not neglect the significance of trace albumin and SG when interpreting urinalysis results. © 2018 The Author(s). Published by S. Karger AG, Basel.

  2. The sensitivity and specificity of a urine based Rapid Diagnostic Test for the diagnosis of plasmodium falciparum in a malaria endemic area in Odisha, India.

    PubMed

    Samal, Ajit Gopal; Behera, Prativa Kumari; Mohanty, Akshay Kumar; Satpathi, Sanghamitra; Kumar, Abhishek; Panda, Rabi Ratna; Minz, Aruna Mukti; Mohanty, Sanjib; Samal, Abhijit; Van Der Pluijm, Rob W

    2017-10-01

    Rapid and accurate diagnosis is crucial in the treatment of malaria. Rapid Diagnostic Tests (RDTs) using blood have been recommended by the WHO as an acceptable method for the diagnosis of malaria. RDTs provide results quickly, is simple to use and easy to interpret. However, its use requires collection of blood by skin puncture. Hence the aim of the pilot study is to explore the sensitivity and specificity of RDTs using urine (collected non-invasively) for diagnosis of Plasmodium falciparum malaria and to assess the relation between parasite density in blood with HRP-2 Ag detection in urine. All fever cases admitted to Ispat General Hospital (IGH) Rourkela, India, during June 2012-March 2013 with a clinical diagnosis of malaria were examined for the presence of asexual forms of P. falciparum in peripheral blood smears. All smear positive febrile patients who met the eligibility criteria were enrolled. Smear negative fever cases were enrolled as control cases. RDTs were performed using both urine and blood samples by using commercially available blood specific kits. Sixty blood smear positive cases and 51 febrile blood smear negative cases were enrolled. Sensitivity and specificity of RDT urine were 86.67% (95%CI:75.83-93.09) and 94.12% (95%CI:84.08-97.98) respectively whereas those of RDT blood were 91.67% (95% CI: 81.93-96.39) and 98.04% (95% CI 89.7-99.65). The sensitivity of both RDT urine as well as RDT blood were found to be dependent on the level of parasitemia. Results of this study are promising. Larger studies are needed to assess whether RDTs using urine could serve as a practical, reliable method for the detection of P. falciparum in a non-invasive manner where invasive blood taking is less feasible.

  3. Optimizing urine drug testing for monitoring medication compliance in pain management.

    PubMed

    Melanson, Stacy E F; Ptolemy, Adam S; Wasan, Ajay D

    2013-12-01

    It can be challenging to successfully monitor medication compliance in pain management. Clinicians and laboratorians need to collaborate to optimize patient care and maximize operational efficiency. The test menu, assay cutoffs, and testing algorithms utilized in the urine drug testing panels should be periodically reviewed and tailored to the patient population to effectively assess compliance and avoid unnecessary testing and cost to the patient. Pain management and pathology collaborated on an important quality improvement initiative to optimize urine drug testing for monitoring medication compliance in pain management. We retrospectively reviewed 18 months of data from our pain management center. We gathered data on test volumes, positivity rates, and the frequency of false positive results. We also reviewed the clinical utility of our testing algorithms, assay cutoffs, and adulterant panel. In addition, the cost of each component was calculated. The positivity rate for ethanol and 3,4-methylenedioxymethamphetamine were <1% so we eliminated this testing from our panel. We also lowered the screening cutoff for cocaine to meet the clinical needs of the pain management center. In addition, we changed our testing algorithm for 6-acetylmorphine, benzodiazepines, and methadone. For example, due the high rate of false negative results using our immunoassay-based benzodiazepine screen, we removed the screening portion of the algorithm and now perform benzodiazepine confirmation up front in all specimens by liquid chromatography-tandem mass spectrometry. Conducting an interdisciplinary quality improvement project allowed us to optimize our testing panel for monitoring medication compliance in pain management and reduce cost. Wiley Periodicals, Inc.

  4. Urine Cytology

    MedlinePlus

    ... types of cells were found in your urine sample. You may need to repeat the test. Negative. This means no cancer cells were identified in your urine sample. Atypical. This indicates that some abnormalities were found ...

  5. CK (Creatine Kinase) Test

    MedlinePlus

    ... you have muscle weakness, muscle aches, and/or dark urine and your healthcare practitioner suspects muscle damage; ... such as: Muscle pain or aches Muscle weakness Dark urine (The urine may be dark because of ...

  6. Creatinine

    MedlinePlus

    ... then passes out of the body in your urine. If you have kidney disease, the level of creatinine in your blood increases. Blood (serum) and urine tests can check your creatinine levels. The tests ...

  7. Use of mass spectrometry fingerprinting to identify urinary metabolites after consumption of specific foods.

    PubMed

    Lloyd, Amanda J; Favé, Gaëlle; Beckmann, Manfred; Lin, Wanchang; Tailliart, Kathleen; Xie, Long; Mathers, John C; Draper, John

    2011-10-01

    The lack of robust biological markers of dietary exposure hinders the quantitative understanding of causal relations between diet and health. We aimed to develop an efficient procedure to discover metabolites in urine that may have future potential as biomarkers of acute exposure to foods of high public health importance. Twenty-four participants were provided with a test breakfast in which the cereal component of a standardized breakfast was replaced by 1 of 4 foods of high public health importance; 1.5-, 3-, and 4.5-h postprandial urine samples were collected. Flow infusion electrospray-ionization mass spectrometry followed by supervised multivariate data analysis was used to discover signals resulting from consumption of each test food. Fasted-state urine samples provided a universal comparator for food biomarker lead discovery in postprandial urine. The filtering of data features associated with consumption of the common components of the standardized breakfast improved discrimination models and readily identified metabolites that showed consumption of specific test foods. A combination of trimethylamine-N-oxide and 1-methylhistidine was associated with salmon consumption. Novel ascorbate derivatives were discovered in urine after consumption of either broccoli or raspberries. Sulphonated caffeic acid and sulphonated methyl-epicatechin concentrations increased dramatically after consumption of raspberries. This biomarker lead discovery strategy can identify urinary metabolites associated with acute exposure to individual foods. Future studies are required to validate the specificity and utility of potential biomarkers in an epidemiologic context.

  8. Cannabis Use Surveillance by Sweat Analysis.

    PubMed

    Gambelunghe, Cristiana; Fucci, Nadia; Aroni, Kyriaki; Bacci, Mauro; Marcelli, Antonio; Rossi, Riccardo

    2016-10-01

    Sweat testing, an alternative matrix for establishing drug abuse, offers additional benefits to the more common biological samples. The authors developed a procedure using gas chromatography-mass spectrometry to test for Δ9-tetrahydrocannabinol, 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid, cannabinol (CBN), and cannabidiol (CBD) in a sweat patch. The results were compared with urine and hair sample results. Urine, hair, and sweat samples were simultaneously collected from 12 patients who were involved, respectively, in forensic case and monitoring abuse. Selectivity, linearity, limit of detection (LOD), limit of quantification (LOQ), recovery, intraday and interday imprecision, and inaccuracy of the quantification procedure were validated. LODs in hair were 0.05 ng/mg for Δ9-tetrahydrocannabinol, CBN, and CBD, and 0.005 ng/mg for 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid. The LOD for sweat was 0.30 ng/patch for all substances. The LOQ in hair was 0.1 ng/mg for Δ9-tetrahydrocannabinol, CBN, and CBD, and 0.01 ng/mg for 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid. The LOQ was 0.4 ng/patch in sweat for each analyte. Cannabinoid in urine was determined by means of immunochemical screening (cutoff 11-nor-Δ-tetrahydrocannabinol-9-carboxylic acid 50 ng/mL). All subjects tested positive for 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid and Δ9-tetrahydrocannabinol in urine and hair. In sweat samples, Δ9-tetrahydrocannabinol was found in all patches (0.4-2.0 ng/patch); 6 cases were positive for CBN (0.4-0.5 ng/patch) and 3 for CBD (0.4-0.6 ng/patch); 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid was never detected in patches. Present sweat analysis results integrated the information from hair and urine and showed that sweat analysis is a suitable, noninvasive method for monitoring compliance with rehabilitation therapy and for detecting recent cumulative use of cannabinoids.

  9. Biologically Pre-Treated Habitation Waste Water as a Sustainable Green Urine Pre-Treat Solution

    NASA Technical Reports Server (NTRS)

    Jackson, W. Andrew; Thompson, Bret; Sevanthi, Ritesh; Morse, Audra; Meyer, Caitlin; Callahan, Michael

    2017-01-01

    The ability to recover water from urine and flush water is a critical process to allow long term sustainable human habitation in space or bases on the moon or mars. Organic N present as urea or similar compounds can hydrolyze producing free ammonia. This reaction results in an increase in the pH converting ammonium to ammonia which is volatile and not removed by distillation. The increase in pH will also cause precipitation reactions to occur. In order to prevent this, urine on ISS is combined with a pretreat solution. While use of a pretreatment solution has been successful, there are numerous draw backs including: storage and use of highly hazardous solutions, limitations on water recovery (less than 85%), and production of brine with pore dewatering characteristics. We evaluated the use of biologically treated habitation wastewaters (ISS and early planetary base) to replace the current pretreat solution. We evaluated both amended and un-amended bioreactor effluent. For the amended effluent, we evaluated "green" pretreat chemicals including citric acid and citric acid amended with benzoic acid. We used a mock urine/air separator modeled after the urine collection assembly on ISS. The urine/air separator was challenged continually for >6 months. Depending on the test point, the separator was challenged daily with donated urine and flushed with amended or un-amended reactor effluent. We monitored the pH of the urine, flush solution and residual pH in the urine/air separator after each urine event. We also evaluated solids production and biological growth. Our results support the use of both un-amended and amended bioreactor effluent to maintain the operability of the urine /air separator. The ability to use bioreactor effluent could decrease consumable cost, reduce hazards associated with current pre-treat chemicals, allow other membrane based desalination processes to be utilized, and improve brine characteristics.

  10. Getting a Urine Test (For Kids)

    MedlinePlus Videos and Cool Tools

    ... learn a lot from urine tests. Obviously, this test doesn't hurt. And if you know what to expect, it doesn't have to be embarrassing ... Visit the Nemours Web site. Note: All information on KidsHealth® is for ...

  11. Nitrogen test (image)

    MedlinePlus

    ... is performed to check for the amount of urea in urine. Urine is collected over a 24 hour period and is sent to the laboratory for testing. This test is mainly used to assess the amount of dietary protein needed by severely ill patients.

  12. Effect of fulvic acids on the electrolytes physiology in vertebrates

    NASA Astrophysics Data System (ADS)

    Morales, O. Y.; Navarrete, J. M.; Gracia, I.; Macias, L.; Rivera, M.; Sanchez, F.

    2011-10-01

    Fulvic acids are the active principle in humus fertilizers which are the cause of better absorption of mineral ions from soil to plant tissues. Tested in mice by making use of radioactive labeled ions, they showed their action of enhancing by a factor greater than two the filtration through liver of PO 43- and Ca 2+ from digestive tract to blood serum as well as through kidney from blood serum to urine. Following this research, Fe 3+ and I 1- ions labeled with 59Fe and 131I have been tested and reported in the present paper. Results showed that iron ions are completely fixed in red cells, with no residue eliminated by urine, while iodine ions are fixed in thyroid gland, with some residue eliminated by urine. Both ions were fixed in said tissues by factors larger than two when they are escorted by fulvic acids. A general distribution of these ions in blood, urine, feces, liver, kidney and thyroid gland has been surveyed, trying to find the earliest effect of fulvic acids in the physiology of vertebrates.

  13. Copper Is a Host Effector Mobilized to Urine during Urinary Tract Infection To Impair Bacterial Colonization

    PubMed Central

    Hyre, Amanda N.; Kavanagh, Kylie; Kock, Nancy D.; Donati, George L.

    2016-01-01

    ABSTRACT Urinary tract infection (UTI) is a major global infectious disease affecting millions of people annually. Human urinary copper (Cu) content is elevated during UTI caused by uropathogenic Escherichia coli (UPEC). UPEC upregulates the expression of Cu efflux genes during clinical UTI in patients as an adaptive response to host-derived Cu. Whether Cu is mobilized to urine as a host response to UTI and its role in protection against UTI remain unresolved. To address these questions, we tested the hypothesis that Cu is a host effector mobilized to urine during UTI to limit bacterial growth. Our results reveal that Cu is mobilized to urine during UTI caused by the major uropathogens Proteus mirabilis and Klebsiella pneumoniae, in addition to UPEC, in humans. Ceruloplasmin, a Cu-containing ferroxidase, is found at higher levels in UTI urine than in healthy control urine and serves as the molecular source of urinary Cu during UTI. Our results demonstrate that ceruloplasmin decreases the bioavailability of iron in urine by a transferrin-dependent mechanism. Experimental UTI with UPEC in nonhuman primates recapitulates the increased urinary Cu content observed during clinical UTI. Furthermore, Cu-deficient mice are highly colonized by UPEC, indicating that Cu is involved in the limiting of bacterial growth within the urinary tract. Collectively, our results indicate that Cu is a host effector that is involved in protection against pathogen colonization of the urinary tract. Because urinary Cu levels are amenable to modulation, augmentation of the Cu-based host defense against UTI represents a novel approach to limiting bacterial colonization during UTI. PMID:28031261

  14. Effects of processing delay, temperature, and transport tube type on results of quantitative bacterial culture of canine urine.

    PubMed

    Patterson, Carly A; Bishop, Micah A; Pack, Julie D; Cook, Audrey K; Lawhon, Sara D

    2016-01-15

    To determine the impact of processing delay, temperature, and transport tube type on results of quantitative bacterial culture (QBC) of canine urine. Diagnostic test evaluation. 60 mL of pooled urine from 4 dogs, divided into six 10-mL aliquots. Urine aliquots were spiked with bacteria from 1 of 6 independent Escherichia coli cultures to achieve a target bacterial concentration of 10(5) CFUs/mL. One milliliter from each aliquot was transferred into 5 silicone-coated clot tubes (SCTs) and 5 urine transport tubes (UTTs). Samples were stored at 4°C (39°F) and 25°C (77°F) for 0, 8, and 24 hours, and then standard QBCs were performed. Median bacterial concentration for urine samples stored in a UTT for 24 hours at 4°C was lower than that for samples stored in an SCT under the same conditions. Conversely, a substantial decrease in median bacterial concentration was identified for samples stored for 24 hours in an SCT at 25°C, compared with the median concentration for samples stored in a UTT under the same conditions. Median bacterial concentration in samples stored in an SCT at 25°C for 24 hours (275 CFUs/mL) was less than the cutoff typically used to define clinically important bacteriuria by use of urine samples obtained via cystocentesis (ie, > 1,000 CFUs/mL). Canine urine samples submitted for immediate QBC should be transported in plain sterile tubes such as SCTs. When prolonged (24-hour) storage at room temperature is anticipated, urine samples should be transported in UTTs.

  15. Efficacy of new low-cost filtration device for recovering Schistosoma haematobium eggs from urine.

    PubMed

    Gyorkos, T W; Ramsan, M; Foum, A; Khamis, I S

    2001-07-01

    A new, inexpensive filtration device for the diagnosis of urinary schistosomiasis was tested against the commonly used Millipore device. The experimental protocol was performed with 25 urine samples known to be positive for Schistosoma haematobium. The results suggest that the new device is as effective as the Millipore device for the diagnosis of urinary schistosomiasis. Its low cost will be attractive to schistosomiasis control programs.

  16. False Negative Urine Pregnancy Testing with Complete Molar Pregnancy: An Example of the Hook Effect.

    PubMed

    Anderson, Zachary; Larson, Eric; Khan, Muhammad; Bell, Maria

    2016-02-01

    Gestational trophoblastic disease (GTD) encompasses a group of tumors derived from trophoblasts, which normally form the placenta during pregnancy. Human chorionic gonadotropin (hCG) is a glycoprotein composed of an alpha subunit identical to that of thyroid stimulating hormone (TSH), follicle-stimulating hormone (FSH), and luteinizing hormone (LH). Detection of beta-hCG is achievable in both urine and serum samples, proving useful for the detection of normal pregnancy and GTD. However, in the presence of very high levels of beta-hCG, a false negative result may be obtained due to a phenomenon called the "hook effect" or "prozone phenomenon." In certain circumstances, trophoblastic tumors can produce very high levels of beta-hCG, causing misleading results on urine pregnancy testing. A 49-year-old Caucasian female with past medical history pertinent for deep vein thrombosis, ovarian cysts, and osteopenia presented to her internist with report of irregular uterine bleeding for the preceding three months, accompanied by complaints of abdominal bloating, night sweats, and constipation. The patient stated she had completed two negative qualitative urine pregnancy tests and had been seen by both gynecology and gastroenterology, with recommendations to start supplemental estrogen for her symptoms and begin additional fiber intake for irritable bowel syndrome, respectively. Despite negative urine beta-hCG, a quantitative serum beta-hCG was obtained and revealed a level greater than 200,000 international units (IU). The patient was referred to gynecologic oncology and an open abdominal hysterectomy with preservation of her ovaries was performed. Histopathologic examination showed a complete hydatiform mole with no evidence of invasion. The case highlights the importance of clinical judgment in modern medicine, where biochemical methods and imaging modalities have become main stays in diagnosis. As mentioned, there are ways to reduce the incidence of the hook effect, but with added time and cost. Clinicians need to consider the possibility of the hook effect for instances where the clinical picture points to a disease entity despite negative test results. Delaying diagnoses, as illustrated with GTD, has the potential to cause significant morbidity and mortality.

  17. Cross-Fostering of Male Mice Subtly Affects Female Olfactory Preferences

    PubMed Central

    Liu, Ying-Juan; Zhang, Yao-Hua; Li, Lai-Fu; Du, Rui-Qing; Zhang, Jin-Hua; Zhang, Jian-Xu

    2016-01-01

    The maternal environment has been shown to influence female olfactory preferences through early chemosensory experience. However, little is known about the influence of the maternal environment on chemosignals. In this study, we used two inbred mouse strains, C57BL/6 (C57) and BALB/c (BALB), and explored whether adoption could alter male chemosignals and thus influence female olfactory preferences. In Experiment 1, C57 pups were placed with BALB dams. Adult BALB females then served as the subjects in binary choice tests between paired male urine odours (BALB vs. C57, BALB vs. adopted C57 and C57 vs. adopted C57). In Experiment 2, BALB pups were placed with C57 dams, and C57 females served as the subjects in binary choice tests between paired male urine odours (C57 vs. BALB, C57 vs. adopted BALB, and BALB vs. adopted BALB). In both experiments, we found that females preferred the urine of males from different genetic backgrounds, suggesting that female olfactory preferences may be driven by genetic compatibility. Cross-fostering had subtle effects on female olfactory preferences. Although the females showed no preference between the urine odours of adopted and non-adopted males of the other strain, the BALB females preferred the urine odour of BALB males to that of adopted C57 males, whereas the C57 females showed no preference between the urine odour of C57 and adopted BALB males. Using gas chromatography-mass spectrometry (GC-MS) and stepwise discriminant analysis, we found that the ratios of volatile chemicals from urine and preputial gland secretions were altered in the fostered male mice; these changes may have resulted in the behavioural changes observed in the females. Overall, the results suggest that female mice prefer urine odours from males with different genetic backgrounds; this preference may be driven by genetic compatibility. The early maternal environment influences the chemosignals of males and thus may influence the olfactory preferences of females. Our study provides additional evidence in support of genotype-dependent maternal influences on phenotypic variability in adulthood. PMID:26756471

  18. The Diagnosis of Urinary Tract infection in Young children (DUTY): a diagnostic prospective observational study to derive and validate a clinical algorithm for the diagnosis of urinary tract infection in children presenting to primary care with an acute illness.

    PubMed Central

    Hay, Alastair D; Birnie, Kate; Busby, John; Delaney, Brendan; Downing, Harriet; Dudley, Jan; Durbaba, Stevo; Fletcher, Margaret; Harman, Kim; Hollingworth, William; Hood, Kerenza; Howe, Robin; Lawton, Michael; Lisles, Catherine; Little, Paul; MacGowan, Alasdair; O'Brien, Kathryn; Pickles, Timothy; Rumsby, Kate; Sterne, Jonathan Ac; Thomas-Jones, Emma; van der Voort, Judith; Waldron, Cherry-Ann; Whiting, Penny; Wootton, Mandy; Butler, Christopher C

    2016-01-01

    BACKGROUND It is not clear which young children presenting acutely unwell to primary care should be investigated for urinary tract infection (UTI) and whether or not dipstick testing should be used to inform antibiotic treatment. OBJECTIVES To develop algorithms to accurately identify pre-school children in whom urine should be obtained; assess whether or not dipstick urinalysis provides additional diagnostic information; and model algorithm cost-effectiveness. DESIGN Multicentre, prospective diagnostic cohort study. SETTING AND PARTICIPANTS Children < 5 years old presenting to primary care with an acute illness and/or new urinary symptoms. METHODS One hundred and seven clinical characteristics (index tests) were recorded from the child's past medical history, symptoms, physical examination signs and urine dipstick test. Prior to dipstick results clinician opinion of UTI likelihood ('clinical diagnosis') and urine sampling and treatment intentions ('clinical judgement') were recorded. All index tests were measured blind to the reference standard, defined as a pure or predominant uropathogen cultured at ≥ 10(5) colony-forming units (CFU)/ml in a single research laboratory. Urine was collected by clean catch (preferred) or nappy pad. Index tests were sequentially evaluated in two groups, stratified by urine collection method: parent-reported symptoms with clinician-reported signs, and urine dipstick results. Diagnostic accuracy was quantified using area under receiver operating characteristic curve (AUROC) with 95% confidence interval (CI) and bootstrap-validated AUROC, and compared with the 'clinician diagnosis' AUROC. Decision-analytic models were used to identify optimal urine sampling strategy compared with 'clinical judgement'. RESULTS A total of 7163 children were recruited, of whom 50% were female and 49% were < 2 years old. Culture results were available for 5017 (70%); 2740 children provided clean-catch samples, 94% of whom were ≥ 2 years old, with 2.2% meeting the UTI definition. Among these, 'clinical diagnosis' correctly identified 46.6% of positive cultures, with 94.7% specificity and an AUROC of 0.77 (95% CI 0.71 to 0.83). Four symptoms, three signs and three dipstick results were independently associated with UTI with an AUROC (95% CI; bootstrap-validated AUROC) of 0.89 (0.85 to 0.95; validated 0.88) for symptoms and signs, increasing to 0.93 (0.90 to 0.97; validated 0.90) with dipstick results. Nappy pad samples were provided from the other 2277 children, of whom 82% were < 2 years old and 1.3% met the UTI definition. 'Clinical diagnosis' correctly identified 13.3% positive cultures, with 98.5% specificity and an AUROC of 0.63 (95% CI 0.53 to 0.72). Four symptoms and two dipstick results were independently associated with UTI, with an AUROC of 0.81 (0.72 to 0.90; validated 0.78) for symptoms, increasing to 0.87 (0.80 to 0.94; validated 0.82) with the dipstick findings. A high specificity threshold for the clean-catch model was more accurate and less costly than, and as effective as, clinical judgement. The additional diagnostic utility of dipstick testing was offset by its costs. The cost-effectiveness of the nappy pad model was not clear-cut. CONCLUSIONS Clinicians should prioritise the use of clean-catch sampling as symptoms and signs can cost-effectively improve the identification of UTI in young children where clean catch is possible. Dipstick testing can improve targeting of antibiotic treatment, but at a higher cost than waiting for a laboratory result. Future research is needed to distinguish pathogens from contaminants, assess the impact of the clean-catch algorithm on patient outcomes, and the cost-effectiveness of presumptive versus dipstick versus laboratory-guided antibiotic treatment. FUNDING The National Institute for Health Research Health Technology Assessment programme. PMID:27401902

  19. EDRN Pre-Validation of Multiplex Biomarker in Urine — EDRN Public Portal

    Cancer.gov

    The goal of this proposal is to begin to establish an EDRN “pre-validation” trial of a multiplex set of transcripts, including the ETS gene fusions, in post-DRE urine sediments. As can be evidenced by our preliminary data, we have established the utility of this multiplex urine test (which includes TMPRSS-ERG, SPINK1, PCA3 and GOLPH2) in a cohort of prospectively collected urine sediments from the University of Michigan EDRN CEVC site (collected by co-I, Dr. John Wei). In this proposal, we will run this multiplex assay on prospectively collected post-DRE urines collected from other EDRN sites. The idea is to couple this “pre-validation” study with an EDRN validation trial under consideration for the Gen-Probe PCA3 urine test (directed by Drs. John Wei and Harry Rittenhouse).

  20. Detection of Novel Visible-Light Region Absorbance Peaks in the Urine after Alkalization in Patients with Alkaptonuria

    PubMed Central

    Tokuhara, Yasunori; Shukuya, Kenichi; Tanaka, Masami; Mouri, Mariko; Ohkawa, Ryunosuke; Fujishiro, Midori; Takahashi, Tomoo; Okubo, Shigeo; Yokota, Hiromitsu; Kurano, Makoto; Ikeda, Hitoshi; Yamaguchi, Seiji; Inagaki, Shinobu; Ishige-Wada, Mika; Usui, Hiromi; Yatomi, Yutaka; Shimosawa, Tatsuo

    2014-01-01

    Background Alkaptonuria, caused by a deficiency of homogentisate 1,2-dioxygenase, results in the accumulation of homogentisic acid (2,5-dihydroxyphenylacetic acid, HGA) in the urine. Alkaptonuria is suspected when the urine changes color after it is left to stand at room temperature for several hours to days; oxidation of homogentisic acid to benzoquinone acetic acid underlies this color change, which is accelerated by the addition of alkali. In an attempt to develop a facile screening test for alkaptonuria, we added alkali to urine samples obtained from patients with alkaptonuria and measured the absorbance spectra in the visible light region. Methods We evaluated the characteristics of the absorption spectra of urine samples obtained from patients with alkaptonuria (n = 2) and compared them with those of urine specimens obtained from healthy volunteers (n = 5) and patients with phenylketonuria (n = 3), and also of synthetic homogentisic acid solution after alkalization. Alkalization of the urine samples and HGA solution was carried out by the addition of NaOH, KOH or NH4OH. The sample solutions were incubated at room temperature for 1 min, followed by measurement of the absorption spectra. Results Addition of alkali to alkaptonuric urine yielded characteristic absorption peaks at 406 nm and 430 nm; an identical result was obtained from HGA solution after alkalization. The absorbance values at both 406 nm and 430 nm increased in a time-dependent manner. In addition, the absorbance values at these peaks were greater in strongly alkaline samples (NaOH- KOH-added) as compared with those in weakly alkaline samples (NH4OH-added). In addition, the peaks disappeared following the addition of ascorbic acid to the samples. Conclusions We found two characteristic peaks at 406 nm and 430 nm in both alkaptonuric urine and HGA solution after alkalization. This new quick and easy method may pave the way for the development of an easy method for the diagnosis of alkaptonuria. PMID:24466168

  1. Drug Testing in a University Athletic Program: Protocol and Implementation.

    ERIC Educational Resources Information Center

    Rovere, George D.; And Others

    1986-01-01

    An athletic drug education, counseling, and screening program at Wake Forest University is described. Decisions regarding which athletes to test, which drugs to test for and how to test for them, how to collect urine samples, and measures taken for a positive result are discussed. (MT)

  2. High Throughput Method of Extracting and Counting Strontium-90 in Urine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shkrob, I.; Kaminski, M.; Mertz, C.

    2016-03-01

    A method has been developed for the rapid extraction of Sr-90 from the urine of individuals exposed to radiation in a terrorist attack. The method employs two chromatographic ion-exchange materials: Diphonix resin and Sr resin, both of which are commercially available. The Diphonix resin reduces the alkali ion concentrations below 10 mM, and the Sr resin concentrates and decontaminates strontium-90. Experimental and calculational data are given for a variety of test conditions. On the basis of these results, a flowsheet has been developed for the rapid concentration and extraction of Sr-90 from human urine samples for subsequent beta-counting.

  3. Pregnancy test

    MedlinePlus

    For the urine test, you urinate into a cup. For the blood test, the health care provider uses a needle and syringe to draw blood from your vein into a tube. Any discomfort you might feel from the blood draw will only last a few seconds.

  4. Urine sampling and collection system optimization and testing

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Geating, J. A.; Koesterer, M. G.

    1975-01-01

    A Urine Sampling and Collection System (USCS) engineering model was developed to provide for the automatic collection, volume sensing and sampling of urine from each micturition. The purpose of the engineering model was to demonstrate verification of the system concept. The objective of the optimization and testing program was to update the engineering model, to provide additional performance features and to conduct system testing to determine operational problems. Optimization tasks were defined as modifications to minimize system fluid residual and addition of thermoelectric cooling.

  5. Pharmacokinetic Modeling of Intranasal Scopolamine in Plasma Saliva and Urine

    NASA Technical Reports Server (NTRS)

    Wu, L.; Tam, V. H.; Chow, D. S. L.; Putcha, L.

    2015-01-01

    An intranasal gel dosage formulation of scopolamine (INSCOP) was developed for the treatment of Space Motion Sickness (SMS). The bioavailability and pharmacokinetics (PK) were evaluated under IND (Investigational New Drug) guidelines. The aim of the project was to develop a PK model that can predict the relationships among plasma, saliva and urinary scopolamine concentrations using data collected from the IND clinical trial protocol with INSCOP. Twelve healthy human subjects were administered at three dose levels (0.1, 0.2 and 0.4 mg) of INSCOP. Serial blood, saliva and urine samples were collected between 5 min to 24 h after dosing and scopolamine concentrations were measured by using a validated LC-MS-MS assay. PK compartmental models, using actual dosing and sampling time, were established using Phoenix (version 1.2). Model selection was based on a likelihood ratio test on the difference of criteria (-2LL (i.e. log-likelihood ratio test)) and comparison of the quality of fit plots. The results: Predictable correlations among scopolamine concentrations in compartments of plasma, saliva and urine were established, and for the first time the model satisfactorily predicted the population and individual PK of INSCOP in plasma, saliva and urine. The model can be utilized to predict the INSCOP plasma concentration by saliva and urine data, and it will be useful for monitoring the PK of scopolamine in space and other remote environments using non-invasive sampling of saliva and/or urine.

  6. Creatinine concentrations of accumulated intrauterine fluid to confirm the clinical diagnosis of urometra in mares.

    PubMed

    Schnobrich, M R; Gordon, D L; Scoggin, C F; Bradecamp, E A; Canisso, I F

    2017-03-25

    Urine pooling, as a persistent condition, is a cause of infertility in mares due to endometrial inflammation and sperm toxicity. Identification of urometra can be challenging in mares presenting with the condition intermittently, or when urine flows into the uterus but is undetectable in the vagina. Currently, there are no reported objective methods to confirm the clinical diagnosis of urine contamination in intrauterine-fluid accumulations. Since creatinine is present in high concentrations in urine and does not diffuse across cell membranes, creatinine concentration should be increased in mares with urometra, but negligible in normal and mares with intrauterine fluid accumulation (non-urometra cases). To test this hypothesis, creatinine concentrations of intrauterine fluid were measured in mares with a clinical diagnosis of urine accumulation (n=9) or intrauterine fluid containing no urine (n=10). Results showed that creatinine concentrations (mg/dl) were significantly higher in mares that had a clinical diagnosis of urometra (42.8±12.6, range 4.1-109.2) compared with those that did not (0.38±0.1, range 0-0.9). Also, two mares after urethral extension surgery demonstrated a remarkable reduction in creatinine concentrations. This study highlights an undocumented approach to confirm a clinical diagnosis of urometra in mares; the authors anticipate that testing for creatinine in the uterine fluid of mares may become a standard tool for identifying urometra in mares and confirming the success of urogenital surgeries. British Veterinary Association.

  7. Promoting appropriate urine culture management to improve health care outcomes and the accuracy of catheter-associated urinary tract infections.

    PubMed

    Garcia, Robert; Spitzer, Eric D

    2017-10-01

    Published literature indicates that the unjustified ordering or improper collection of urine for urinalysis or culture from either catheterized patients or those without indwelling devices, or misinterpretation of positive results, often leads to adverse health care events, including increased financial burdens, overreporting of mandated catheter-associated urinary tract infection events, overtreatment of patients with antimicrobial agents, selection of multidrug-resistant organisms, and Clostridium difficile infection. Moreover, national guidelines that provide evidence-based direction on core processes that form the basis for subsequent clinical therapy decisions or surveillance interpretations; that is, the appropriate ordering and collection of urine for laboratory testing and the treatment of patients with symptomatic urinary tract infection, are not widely known or lack adherence. This article provides published evidence on the influence of inappropriate ordering of urine specimens and subsequent treatment of asymptomatic bacteriuria and associated adverse effects; reviews research on bacterial contamination and preservation; and delineates best practices in the collection, handling, and testing of urine specimens for culture or for biochemical analysis in both catheterized and noncatheterized patients. The goal is to provide infection preventionists (IPs) with a cohesive evidence-based framework that will assist them in facilitating the implementation of a urine culture management program that reduces patient harms, enhances the accuracy of catheter-associated urinary tract infection surveillance, improves antibiotic stewardship, and reduces costs. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  8. Diagnostic Value of the Urine Mucus Test in Childhood Masturbation among Children below 12 Years of Age: A Cross-Sectional Study from Iran.

    PubMed

    Doust, Zarin Keihani; Shariat, Mamak; Zabandan, Neda; Tabrizi, Aidin; Tehrani, Fatemeh

    2016-07-01

    Childhood masturbation (CM) is considered a variant of normal sexual behavior; however, it is commonly misdiagnosed as epilepsy and movement disorders. As the first study from Iran, we analyzed a large population of infants and children with CM in a case-control study and evaluated the value of mucus in urine analysis as an alternative diagnostic tool for CM. A total of 623 children referred to the Pediatric Neurology Clinic of Imam Khomeini Hospital for an evaluation of seizure or movement disorders were studied between 2008 and 2011. Totally, 359 children were found to have masturbatory behaviors (Group A) and the rest (264) were assigned to Group B. CM was diagnosed by direct observation. Collected data comprised demographic characteristics, clinical and neurodevelopmental examinations, laboratory findings (particularly urine analysis), and electrocardiography. The age of the children with CM was below 12 years old, and the girl-to-boy ratio was 7:1. Mucus in urine was positive in 357 (99.44%) children in Group A and 22 (8.3%) in Group B (P<0.001). A significant correlation was found between the presence of mucus in urine and masturbatory behaviors (P<0.001). Our findings suggest that the presence of mucus in urine can be used as an alternative laboratory test in children with CM below 12 years old and even in infants (≤24 months old). Further studies are needed to confirm the results.

  9. Urine Concentration and Pyuria for Identifying UTI in Infants.

    PubMed

    Chaudhari, Pradip P; Monuteaux, Michael C; Bachur, Richard G

    2016-11-01

    Varying urine white blood cell (WBC) thresholds have been recommended for the presumptive diagnosis of urinary tract infection (UTI) among young infants. These thresholds have not been studied with newer automated urinalysis systems that analyze uncentrifuged urine that might be influenced by urine concentration. Our objective was to determine the optimal urine WBC threshold for UTI in young infants by using an automated urinalysis system, stratified by urine concentration. Retrospective cross-sectional study of infants aged <3 months evaluated for UTI in the emergency department with paired urinalysis and urine culture. UTI was defined as ≥50 000 colony-forming units/mL from catheterized specimens. Test characteristics were calculated across a range of WBC and leukocyte esterase (LE) cut-points, dichotomized into specific gravity groups (dilute <1.015; concentrated ≥1.015). Twenty-seven thousand infants with a median age of 1.7 months were studied. UTI prevalence was 7.8%. Optimal WBC cut-points were 3 WBC/high-power field (HPF) in dilute urine (likelihood ratio positive [LR+] 9.9, likelihood ratio negative [LR‒] 0.15) and 6 WBC/HPF (LR+ 10.1, LR‒ 0.17) in concentrated urine. For dipstick analysis, positive LE has excellent test characteristics regardless of urine concentration (LR+ 22.1, LR‒ 0.12 in dilute urine; LR+ 31.6, LR‒ 0.22 in concentrated urine). Urine concentration should be incorporated into the interpretation of automated microscopic urinalysis in young infants. Pyuria thresholds of 3 WBC/HPF in dilute urine and 6 WBC/HPF in concentrated urine are recommended for the presumptive diagnosis of UTI. Without correction of specific gravity, positive LE by automated dipstick is a reliably strong indicator of UTI. Copyright © 2016 by the American Academy of Pediatrics.

  10. Human Excretion of Polybrominated Diphenyl Ether Flame Retardants: Blood, Urine, and Sweat Study

    PubMed Central

    Genuis, Shelagh K.; Birkholz, Detlef

    2017-01-01

    Commonly used as flame retardants, polybrominated diphenyl ethers (PBDEs) are routinely detected in the environment, animals, and humans. Although these persistent organic pollutants are increasingly recognized as having serious health implications, particularly for children, this is the first study, to our knowledge, to investigate an intervention for human elimination of bioaccumulated PBDEs. Objectives. To determine the efficacy of blood, urine, and perspiration as PBDE biomonitoring mediums; assess excretion of five common PBDE congeners (28, 47, 99, 100, and 153) in urine and perspiration; and explore the potential of induced sweating for decreasing bioaccumulated PBDEs. Results. PBDE congeners were not found in urine samples; findings focus on blood and perspiration. 80% of participants tested positive in one or more body fluids for PBDE 28, 100% for PBDE 47, 95% for PBDE 99, and 90% for PBDE 100 and PBDE 153. Induced perspiration facilitated excretion of the five congeners, with different rates of excretion for different congeners. Conclusion. Blood testing provides only a partial understanding of human PBDE bioaccumulation; testing of both blood and perspiration provides a better understanding. This study provides important baseline evidence for regular induced perspiration as a potential means for therapeutic PBDE elimination. Fetotoxic and reproductive effects of PBDE exposure highlight the importance of further detoxification research. PMID:28373979

  11. Electrolytic pretreatment of urine

    NASA Technical Reports Server (NTRS)

    1977-01-01

    Electrolysis has been under evaluation for several years as a process to pretreat urine for ultimate recovery of potable water in manned spacecraft applications. The conclusions that were drawn from this investigation are the following: (1) A platinum alloy containing 10 percent rhodium has been shown to be an effective, corrosion-resistant anode material for the electrolytic pretreatment of urine. Black platinum has been found to be suitable as a cathode material. (2) The mechanism of the reactions occurring during the electrolysis of urine is two-stage: (a) a total Kjeldahl nitrogen and total organic carbon (TOC) removal in the first stage is the result of electrochemical oxidation of urea to CO2, H2O, and ammonia followed by chloride interaction to produce N2 from ammonia, (b) after the urea has been essentially removed and the chloride ions have no more ammonia to interact with, the chloride ions start to oxidize to higher valence states, thus producing perchlorates. (3) Formation of perchlorates can be suppressed by high/low current operation, elevated temperature, and pH adjustment. (4) UV-radiation showed promise in assisting electrolytic TOC removal in beaker tests, but was not substantiated in limited single cell testing. This may have been due to non-optimum configurations of the single cell test rig and the light source.

  12. [Mutagenic evaluation of the urine of rats treated with oils implicated in the toxic oil syndrome using bacterial tests].

    PubMed

    Barrueco, C; Sladek, F; Canga, C; Valcarce, E; de la Peña, E; Alia, M; Laborda, E

    1983-01-01

    The mutagenic activity of the urine of pregnant rats treated with toxic oil syndrome-related rape seed oil or with edible oil was evaluated by means of the Ames and Green tests. It was found that the urine of the pregnant rats treated with "Jen" oil, that was related to the toxic oil syndrome, was mutagenic.

  13. Albumin testing in urine using a smart-phone

    PubMed Central

    Coskun, Ahmet F.; Nagi, Richie; Sadeghi, Kayvon; Phillips, Stephen; Ozcan, Aydogan

    2013-01-01

    We demonstrate a digital sensing platform, termed Albumin Tester, running on a smart-phone that images and automatically analyses fluorescent assays confined within disposable test tubes for sensitive and specific detection of albumin in urine. This light-weight and compact Albumin Tester attachment, weighing approximately 148 grams, is mechanically installed on the existing camera unit of a smart-phone, where test and control tubes are inserted from the side and are excited by a battery powered laser diode. This excitation beam, after probing the sample of interest located within the test tube, interacts with the control tube, and the resulting fluorescent emission is collected perpendicular to the direction of the excitation, where the cellphone camera captures the images of the fluorescent tubes through the use of an external plastic lens that is inserted between the sample and the camera lens. The acquired fluorescent images of the sample and control tubes are digitally processed within one second through an Android application running on the same cellphone for quantification of albumin concentration in urine specimen of interest. Using a simple sample preparation approach which takes ~ 5 minutes per test (including the incubation time), we experimentally confirmed the detection limit of our sensing platform as 5–10 μg/mL (which is more than 3 times lower than clinically accepted normal range) in buffer as well as urine samples. This automated albumin testing tool running on a smart-phone could be useful for early diagnosis of kidney disease or for monitoring of chronic patients, especially those suffering from diabetes, hypertension, and/or cardiovascular diseases. PMID:23995895

  14. Analysis of cannabis in oral fluid specimens by GC-MS with automatic SPE.

    PubMed

    Choi, Hyeyoung; Baeck, Seungkyung; Kim, Eunmi; Lee, Sooyeun; Jang, Moonhee; Lee, Juseon; Choi, Hwakyung; Chung, Heesun

    2009-12-01

    Methamphetamine (MA) is the most commonly abused drug in Korea, followed by cannabis. Traditionally, MA analysis is carried out on both urine and hair samples and cannabis analysis in urine samples only. Despite the fact that oral fluid has become increasingly popular as an alternative specimen in the field of driving under the influence of drugs (DUID) and work place drug testing, its application has not been expanded to drug analysis in Korea. Oral fluid is easy to collect and handle and can provide an indication of recent drug abuse. In this study, we present an analytical method using GC-MS to determine tetrahydrocannabinol (THC) and its main metabolite 11-nor-delta9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) in oral fluid. The validated method was applied to oral fluid samples collected from drug abuse suspects and the results were compared with those in urine. The stability of THC and THC-COOH in oral fluid stored in different containers was also investigated. Oral fluid specimens from 12 drug abuse suspects, submitted by the police, were collected by direct expectoration. The samples were screened with microplate ELISA. For confirmation they were extracted using automated SPE with mixed-mode cation exchange cartridge, derivatized and analyzed by GC-MS using selective ion monitoring (SIM). The concentrations ofTHC and THC-COOH in oral fluid showed a large variation and the results from oral fluid and urine samples from cannabis abusers did not show any correlation. Thus, detailed information about time interval between drug use and sample collection is needed to interpret the oral fluid results properly. In addition, further investigation about the detection time window ofTHC and THC-COOH in oral fluid is required to substitute oral fluid for urine in drug testing.

  15. Bilirubin in Urine: MedlinePlus Lab Test Information

    MedlinePlus

    ... Information → Bilirubin in Urine URL of this page: https://medlineplus.gov/labtests/bilirubininurine.html Bilirubin in Urine ... 2017 Mar 23]; [about 3 screens]. Available from: https://www.liverfoundation.org/for-patients/about-the-liver/ ...

  16. Urge incontinence

    MedlinePlus

    ... much urine you lost. Pelvic or abdominal ultrasound . Post void residual to measure the amount of urine left in your bladder after you urinate. Urinalysis to check for infection . Urinary stress test (you stand with a full bladder and cough). ...

  17. Diagnosis of neonatal group B Streptococcus sepsis by nested-PCR of residual urine samples

    PubMed Central

    Cezarino, Bruno Nicolino; Yamamoto, Lidia; Del Negro, Gilda Maria Barbaro; Rocha, Daisy; Okay, Thelma Suely

    2008-01-01

    Group B streptococcus (GBS) remains the most common cause of early-onset sepsis in newborns. Laboratory gold-standard, broth culture methods are highly specific, but lack sensitivity. The aim of this study was to validate a nested-PCR and to determine whether residue volumes of urine samples obtained by non invasive, non sterile methods could be used to confirm neonatal GBS sepsis. The nested-PCR was performed with primers of the major GBS surface antigen. Unavailability of biological samples to perform life supporting exams, as well as others to elucidate the etiology of infections is a frequent problem concerning newborn patients. Nevertheless, we decided to include cases according to strict criteria: newborns had to present with signs and symptoms compatible with GBS infection; at least one of the following biological samples had to be sent for culture: blood, urine, or cerebrospinal fluid; availability of residue volumes of the samples sent for cultures, or of others collected on the day of hospitalization, prior to antibiotic therapy prescription, to be analyzed by PCR; favorable outcome after GBS empiric treatment. In only one newborn GBS infection was confirmed by cultures, while infection was only presumptive in the other three patients (they fulfilled inclusion criteria but were GBS-culture negative). From a total of 12 biological samples (5 blood, 3 CSF and 4 urine specimen), eight were tested by culture methods (2/8 were positive), and 8 were tested by PCR (7/8 were positive), and only 4 samples were simultaneously tested by both methods (1 positive by culture and 3 by PCR). In conclusion, although based on a restricted number of neonates and samples, our results suggest that the proposed nested-PCR might be used to diagnose GBS sepsis as it has successfully amplified the three types of biological samples analyzed (blood, urine and cerebrospinal fluid), and was more sensitive than culture methods as PCR in urine confirmed diagnosis in all four patients. Moreover, PCR has enabled us to use residue volumes of urine samples collected by non invasive, non sterile methods, what is technically adequate as GBS is not part of the normal urine flora, thus avoiding invasive procedures such as suprapubic bladder punction or transurethral catheterization. At the same time, the use of urine instead of blood samples could help preventing newborns blood spoliation. PMID:24031170

  18. Chemical Method of Urine Volume Measurement

    NASA Technical Reports Server (NTRS)

    Petrack, P.

    1967-01-01

    A system has been developed and qualified as flight hardware for the measurement of micturition volumes voided by crewmen during Gemini missions. This Chemical Urine Volume Measurement System (CUVMS) is used for obtaining samples of each micturition for post-flight volume determination and laboratory analysis for chemical constituents of physiological interest. The system is versatile with respect to volumes measured, with a capacity beyond the largest micturition expected to be encountered, and with respect to mission duration of inherently indefinite length. The urine sample is used for the measurement of total micturition volume by a tracer dilution technique, in which a fixed, predetermined amount of tritiated water is introduced and mixed into the voided urine, and the resulting concentration of the tracer in the sample is determined with a liquid scintillation spectrometer. The tracer employed does not interfere with the analysis for the chemical constituents of the urine. The CUVMS hardware consists of a four-way selector valve in which an automatically operated tracer metering pump is incorporated, a collection/mixing bag, and tracer storage accumulators. The assembled system interfaces with a urine receiver at the selector valve inlet, sample bags which connect to the side of the selector valve, and a flexible hose which carries the excess urine to the overboard drain connection. Results of testing have demonstrated system volume measurement accuracy within the specification limits of +/-5%, and operating reliability suitable for system use aboard the GT-7 mission, in which it was first used.

  19. 21 CFR 862.1509 - Methylmalonic acid (nonquantitative) test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... methylmalonic acid (nonquantitative) test system is a device intended to identify methylmalonic acid in urine. The identification of methylmalonic acid in urine is used in the diagnosis and treatment of...

  20. 21 CFR 862.1509 - Methylmalonic acid (nonquantitative) test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... methylmalonic acid (nonquantitative) test system is a device intended to identify methylmalonic acid in urine. The identification of methylmalonic acid in urine is used in the diagnosis and treatment of...

  1. 21 CFR 862.1509 - Methylmalonic acid (nonquantitative) test system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... methylmalonic acid (nonquantitative) test system is a device intended to identify methylmalonic acid in urine. The identification of methylmalonic acid in urine is used in the diagnosis and treatment of...

  2. 21 CFR 862.1509 - Methylmalonic acid (nonquantitative) test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... methylmalonic acid (nonquantitative) test system is a device intended to identify methylmalonic acid in urine. The identification of methylmalonic acid in urine is used in the diagnosis and treatment of...

  3. 75 FR 16813 - Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-02

    ... Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for Federal... Drug Testing Programs (Mandatory Guidelines). The Mandatory Guidelines were first published in the... of [[Page 16814

  4. Traces of illegal drugs on body surfaces: indicator for consumption or dealing?

    NASA Astrophysics Data System (ADS)

    Aberl, Franz; Bonenberger, Johannes; Berg, Ralf-Peter; Zimmermann, Rudolph; Sachs, Hans W.

    1997-01-01

    Customs investigation and drug enforcement services are interest in a rapid and reliable identification of smugglers and dealers. In contrast workplace testing and traffic controls are aiming at the detection of intoxicated persons via the determination of illegal narcotics in body fluids like urine or blood. DRUGWIPE is a pen size, test strip based immunochemical detector for narcotic contaminations on surfaces. It is extremely simple to apply and takes about two minutes to read test results without depending upon any further technical means. This paper describes the applicability of DRUGWIPE to identify drug smugglers or dealers as well as consumers. With respect to the situation and the initial suspicion the test indicates handling as well as consumption. In cooperation with the Institute for Legal Medicine in Munich suspicious drivers were examined with DRUGWIPE for the abuse of illegal narcotics. Test results from this test series are presented and compared with the results from the blood or urine analysis. The question whether the detected traces of illegal narcotics on the body surface of suspicious drivers are combing transpiration or external contamination are discussed.

  5. The urine dipstick test useful to rule out infections. A meta-analysis of the accuracy

    PubMed Central

    Devillé, Walter LJM; Yzermans, Joris C; van Duijn, Nico P; Bezemer, P Dick; van der Windt, Daniëlle AWM; Bouter, Lex M

    2004-01-01

    Background Many studies have evaluated the accuracy of dipstick tests as rapid detectors of bacteriuria and urinary tract infections (UTI). The lack of an adequate explanation for the heterogeneity of the dipstick accuracy stimulates an ongoing debate. The objective of the present meta-analysis was to summarise the available evidence on the diagnostic accuracy of the urine dipstick test, taking into account various pre-defined potential sources of heterogeneity. Methods Literature from 1990 through 1999 was searched in Medline and Embase, and by reference tracking. Selected publications should be concerned with the diagnosis of bacteriuria or urinary tract infections, investigate the use of dipstick tests for nitrites and/or leukocyte esterase, and present empirical data. A checklist was used to assess methodological quality. Results 70 publications were included. Accuracy of nitrites was high in pregnant women (Diagnostic Odds Ratio = 165) and elderly people (DOR = 108). Positive predictive values were ≥80% in elderly and in family medicine. Accuracy of leukocyte-esterase was high in studies in urology patients (DOR = 276). Sensitivities were highest in family medicine (86%). Negative predictive values were high in both tests in all patient groups and settings, except for in family medicine. The combination of both test results showed an important increase in sensitivity. Accuracy was high in studies in urology patients (DOR = 52), in children (DOR = 46), and if clinical information was present (DOR = 28). Sensitivity was highest in studies carried out in family medicine (90%). Predictive values of combinations of positive test results were low in all other situations. Conclusions Overall, this review demonstrates that the urine dipstick test alone seems to be useful in all populations to exclude the presence of infection if the results of both nitrites and leukocyte-esterase are negative. Sensitivities of the combination of both tests vary between 68 and 88% in different patient groups, but positive test results have to be confirmed. Although the combination of positive test results is very sensitive in family practice, the usefulness of the dipstick test alone to rule in infection remains doubtful, even with high pre-test probabilities. PMID:15175113

  6. Impact of introducing near patient testing for standard investigations in general practice.

    PubMed Central

    Rink, E; Hilton, S; Szczepura, A; Fletcher, J; Sibbald, B; Davies, C; Freeling, P; Stilwell, J

    1993-01-01

    OBJECTIVE--To assess the clinical and economic impact of surgery based near patient testing in general practice for six commonly used biochemical and bacteriological tests. DESIGN--After four months' monitoring, equipment for two bacteriological and four biochemical tests was introduced without cost into 12 practices using a crossover design. Structured request forms were used to monitor laboratory investigations. SETTING--12 general practices in west midlands and south west Thames with list sizes above 9000. MAIN OUTCOME MEASURES--Investigation rates per 1000 consultations. Changes from baseline rates. Reasons for requesting investigations and provisional diagnoses. Cost per test and sensitivity of costs to rate of use. RESULTS--Investigation rates for the six tests rose by 16.5% (from 78.6/1000 consultations to 91.6/1000) when equipment was available in the surgery and reverted to baseline rates when it was withdrawn. The average weekly number of tests when equipment was available ranged from 0.5 to 10.5 (mean 9.0). Cholesterol tests were used as an addition to laboratory testing, usually for screening. Midstream urine analysis was often done in the surgery instead of in the laboratory, although 30% of samples were tested by both methods. Doctors' reasons for investigation and conditions tested were largely unaffected by availability of surgery tests. Costs for surgery tests were higher for all tests except midstream urine. CONCLUSIONS--Availability of surgery based testing increased the number of tests performed. It was cost effective only for midstream urine analysis. PMID:8219952

  7. Quality control of test iodine in urine by spectrophotometry UV-Vis

    NASA Astrophysics Data System (ADS)

    Huda, Thorikul; Nafisah, Durotun; Kumorowulan, Suryati; Lestari, Sri

    2017-12-01

    A quality control of iodine test in with UV-Vis spectrophotometry has been done. The purpose of this research is to find out whether the test results of samples conducted by Clinical Office of Research and Development Of GAKI (BP2GAKI) laboratory are still controlled, feasible and reliable, and still consistent over time, as indicated by the control chart. Quality control parameters are linearity, precision, accuracy, limit of detection, and limit of quantification. Based on the quality control that has been done, obtained linearity (r)= -0.9974, the detection limit and the limit of quantitation are respectively 2.26 µg/L and 7.54 µg/L, while the accuracy is calculated by %recovery and precision with value % RSD are 97.4161% and 1.7136% respectively. The quality control of iodine test in urine using the control chart shows excellent or stable results for 30 days and no variation of the results is very different for each day.

  8. The Diagnosis of Urinary Tract infection in Young children (DUTY): a diagnostic prospective observational study to derive and validate a clinical algorithm for the diagnosis of urinary tract infection in children presenting to primary care with an acute illness.

    PubMed

    Hay, Alastair D; Birnie, Kate; Busby, John; Delaney, Brendan; Downing, Harriet; Dudley, Jan; Durbaba, Stevo; Fletcher, Margaret; Harman, Kim; Hollingworth, William; Hood, Kerenza; Howe, Robin; Lawton, Michael; Lisles, Catherine; Little, Paul; MacGowan, Alasdair; O'Brien, Kathryn; Pickles, Timothy; Rumsby, Kate; Sterne, Jonathan Ac; Thomas-Jones, Emma; van der Voort, Judith; Waldron, Cherry-Ann; Whiting, Penny; Wootton, Mandy; Butler, Christopher C

    2016-07-01

    It is not clear which young children presenting acutely unwell to primary care should be investigated for urinary tract infection (UTI) and whether or not dipstick testing should be used to inform antibiotic treatment. To develop algorithms to accurately identify pre-school children in whom urine should be obtained; assess whether or not dipstick urinalysis provides additional diagnostic information; and model algorithm cost-effectiveness. Multicentre, prospective diagnostic cohort study. Children < 5 years old presenting to primary care with an acute illness and/or new urinary symptoms. One hundred and seven clinical characteristics (index tests) were recorded from the child's past medical history, symptoms, physical examination signs and urine dipstick test. Prior to dipstick results clinician opinion of UTI likelihood ('clinical diagnosis') and urine sampling and treatment intentions ('clinical judgement') were recorded. All index tests were measured blind to the reference standard, defined as a pure or predominant uropathogen cultured at ≥ 10(5) colony-forming units (CFU)/ml in a single research laboratory. Urine was collected by clean catch (preferred) or nappy pad. Index tests were sequentially evaluated in two groups, stratified by urine collection method: parent-reported symptoms with clinician-reported signs, and urine dipstick results. Diagnostic accuracy was quantified using area under receiver operating characteristic curve (AUROC) with 95% confidence interval (CI) and bootstrap-validated AUROC, and compared with the 'clinician diagnosis' AUROC. Decision-analytic models were used to identify optimal urine sampling strategy compared with 'clinical judgement'. A total of 7163 children were recruited, of whom 50% were female and 49% were < 2 years old. Culture results were available for 5017 (70%); 2740 children provided clean-catch samples, 94% of whom were ≥ 2 years old, with 2.2% meeting the UTI definition. Among these, 'clinical diagnosis' correctly identified 46.6% of positive cultures, with 94.7% specificity and an AUROC of 0.77 (95% CI 0.71 to 0.83). Four symptoms, three signs and three dipstick results were independently associated with UTI with an AUROC (95% CI; bootstrap-validated AUROC) of 0.89 (0.85 to 0.95; validated 0.88) for symptoms and signs, increasing to 0.93 (0.90 to 0.97; validated 0.90) with dipstick results. Nappy pad samples were provided from the other 2277 children, of whom 82% were < 2 years old and 1.3% met the UTI definition. 'Clinical diagnosis' correctly identified 13.3% positive cultures, with 98.5% specificity and an AUROC of 0.63 (95% CI 0.53 to 0.72). Four symptoms and two dipstick results were independently associated with UTI, with an AUROC of 0.81 (0.72 to 0.90; validated 0.78) for symptoms, increasing to 0.87 (0.80 to 0.94; validated 0.82) with the dipstick findings. A high specificity threshold for the clean-catch model was more accurate and less costly than, and as effective as, clinical judgement. The additional diagnostic utility of dipstick testing was offset by its costs. The cost-effectiveness of the nappy pad model was not clear-cut. Clinicians should prioritise the use of clean-catch sampling as symptoms and signs can cost-effectively improve the identification of UTI in young children where clean catch is possible. Dipstick testing can improve targeting of antibiotic treatment, but at a higher cost than waiting for a laboratory result. Future research is needed to distinguish pathogens from contaminants, assess the impact of the clean-catch algorithm on patient outcomes, and the cost-effectiveness of presumptive versus dipstick versus laboratory-guided antibiotic treatment. The National Institute for Health Research Health Technology Assessment programme.

  9. [Uniform analyzes of drugs in urine needed for rule of law].

    PubMed

    Hansson, Therese; Helander, Anders; Beck, Olof; Elmgren, Anders; Kugelberg, Fredrik; Kronstrand, Robert

    2015-09-22

    Drugs of abuse testing is used in various areas of society for detection and follow-up of drug use. In routine laboratory drug testing, immunoassays are employed for initial screening of specimens to indicate the presence of drugs. To confirm a positive screening test, a secondary analysis by mass spectrometry is performed. The "cut-off" is the pre-defined concentration threshold of a drug or drug metabolite above which the sample is considered positive. A reading below this level implies a negative test result. Swedish drug testing laboratories currently employ varying cut-offs to distinguish between a positive and a negative test result. Because a positive drug test may have serious legal consequences to the individual, it is of importance that testing is performed and judged equally, regardless of where it is performed. A national harmonization of cut-offs is therefore warranted. Based on data from four major Swedish drug testing laboratories, and considering the recommendations in international guidelines, a proposal for national harmonization of urine cut-offs for the most common set of drugs of abuse is presented.

  10. 32 CFR 634.8 - Implied consent.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... to blood, breath, or urine tests. Persons who drive on the installation shall be deemed to have given their consent to evidential tests for alcohol or other drug content of their blood, breath, or urine...

  11. Measurement of glomerular filtration rate in the conscious rat.

    PubMed

    Pestel, Sabine; Krzykalla, Volker; Weckesser, Gerhard

    2007-01-01

    Glomerular filtration rate (GFR) is an important parameter for studying drug-induced impairments on renal function in rats. The GFR is calculated from the concentration of creatinine and blood urea nitrogen (BUN) in serum and in urine, respectively. Following current protocols serum and urine samples must be taken from the same animal. Thus, in order to determine time-dependent effects it is necessary to use for each time point one separated group of animals. We developed a statistical test which allows analyzing the GFR from two different groups of animals: one used for repeated serum and the other one used for repeated urine analysis. Serum and urine samples were taken from two different sets of rats which were otherwise treated identically, i.e. drug doses, routes of administration (per os or per inhalation) and tap water loading. For each dose group GFR mean, standard deviation and statistical analysis to identify differences between the dose groups were determined. After determination of the optimal time points for measurements, the effect on GFR of the three reference compounds, furosemide, hydrochlorothiazide and formoterol, was calculated. The results showed that the diuretic drugs furosemide and hydrochlorothiazide decreased the GFR and the antidiuretic drug formoterol increased the GFR, as counter regulation on urine loss or urine retention, respectively. A mathematical model and the corresponding algorithm were developed, which can be used to calculate the GFR, and to test for differences between groups from two separated sets of rats, one used for urine, and the other one for serum analysis. This new method has the potential to reduce the number of animals needed and to improve the quality of data generated from various groups of animals in renal function studies.

  12. Efficacy of New Low-Cost Filtration Device for Recovering Schistosoma haematobium Eggs from Urine

    PubMed Central

    Gyorkos, Theresa W.; Ramsan, Mahdi; Foum, Ali; Khamis, Iddi Simba

    2001-01-01

    A new, inexpensive filtration device for the diagnosis of urinary schistosomiasis was tested against the commonly used Millipore device. The experimental protocol was performed with 25 urine samples known to be positive for Schistosoma haematobium. The results suggest that the new device is as effective as the Millipore device for the diagnosis of urinary schistosomiasis. Its low cost will be attractive to schistosomiasis control programs. PMID:11427595

  13. Urine Protein and Urine Protein to Creatinine Ratio

    MedlinePlus

    ... Less Common Questions Related Content On This Site Tests: Urinalysis ; Albumin ; Urine Albumin ; Protein Electrophoresis ; Total Protein , BUN , Creatinine , Creatinine Clearance , eGFR Conditions: Kidney Disease , Proteinuria , Pre-eclampsia , Diabetes , Hypertension , Multiple Myeloma , Urinary Tract Infection ...

  14. Cytology exam of urine

    MedlinePlus

    Urine cytology; Bladder cancer - cytology; Urethral cancer - cytology; Renal cancer - cytology ... The test is done to detect cancer of the urinary tract. It is often done when blood is seen in the urine. It is also useful for monitoring people ...

  15. Extended testing of compression distillation.

    NASA Technical Reports Server (NTRS)

    Bambenek, R. A.; Nuccio, P. P.

    1972-01-01

    During the past eight years, the NASA Manned Spacecraft Center has supported the development of an integrated water and waste management system which includes the compression distillation process for recovering useable water from urine, urinal flush water, humidity condensate, commode flush water, and concentrated wash water. This paper describes the design of the compression distillation unit, developed for this system, and the testing performed to demonstrate its reliability and performance. In addition, this paper summarizes the work performed on pretreatment and post-treatment processes, to assure the recovery of sterile potable water from urine and treated urinal flush water.

  16. Conceptual Data Model for Administrative Functions of a Typical Naval Ship, to Include: Personnel, Training, Ship Secretary, Welfare and Recreation, Command Career Counselor, Public Affairs Officer, Educational Services Officer, Master at Arms, and Legal

    DTIC Science & Technology

    1991-09-01

    DEPARTMENT DEPARTMENT DEPARTMENT DEPARTMENT REPAIR DEPARTMENT DEEP AIR WIN AIR REACTOR SUBMERGENCE PARIEMDT DEPDTMENT EPARTMENT (EMBARKED MAINTENANCECOMMAND...URIN DRUG L C,45 N URINALYS E SC: Name o druog 1E to which test was sent for testing URINALYSIS MEMBER BOTTLE INITIAL URIN MBR 9O L N URINALYS E SC...Indicates that meabiei initialed bottle that it was his urine URINALYSIS MEMBER SIGNATURE URIN MBR SI L N URINALYS E SC: Indicates that meber signed log

  17. 45 CFR 78.2 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... provided that such abstinence is documented by the results of periodic urine drug testing conducted during that period; and provided further that such drug testing is conducted using an immunoassay test approved by the Food and Drug Administration for commercial distribution or, in the case of a State offense...

  18. 45 CFR 78.2 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... provided that such abstinence is documented by the results of periodic urine drug testing conducted during that period; and provided further that such drug testing is conducted using an immunoassay test approved by the Food and Drug Administration for commercial distribution or, in the case of a State offense...

  19. 45 CFR 78.2 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... provided that such abstinence is documented by the results of periodic urine drug testing conducted during that period; and provided further that such drug testing is conducted using an immunoassay test approved by the Food and Drug Administration for commercial distribution or, in the case of a State offense...

  20. 45 CFR 78.2 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... provided that such abstinence is documented by the results of periodic urine drug testing conducted during that period; and provided further that such drug testing is conducted using an immunoassay test approved by the Food and Drug Administration for commercial distribution or, in the case of a State offense...

  1. 45 CFR 78.2 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... provided that such abstinence is documented by the results of periodic urine drug testing conducted during that period; and provided further that such drug testing is conducted using an immunoassay test approved by the Food and Drug Administration for commercial distribution or, in the case of a State offense...

  2. Genotyping for DQA1 and PM loci in urine using PCR-based amplification: effects of sample volume, storage temperature, preservatives, and aging on DNA extraction and typing.

    PubMed

    Vu, N T; Chaturvedi, A K; Canfield, D V

    1999-05-31

    Urine is often the sample of choice for drug screening in aviation/general forensic toxicology and in workplace drug testing. In some instances, the origin of the submitted samples may be challenged because of the medicolegal and socioeconomic consequences of a positive drug test. Methods for individualization of biological samples have reached a new boundary with the application of the polymerase chain reaction (PCR) in DNA profiling, but a successful characterization of the urine specimens depends on the quantity and quality of DNA present in the samples. Therefore, the present study investigated the influence of storage conditions, sample volume, concentration modes, extraction procedures, and chemical preservations on the quantity of DNA recovered, as well as the success rate of PCR-based genotyping for DQA1 and PM loci in urine. Urine specimens from male and female volunteers were divided and stored at various temperatures for up to 30 days. The results suggested that sample purification by dialfiltration, using 3000-100,000 molecular weight cut-off filters, did not enhance DNA recovery and typing rate as compared with simple centrifugation procedures. Extraction of urinary DNA by the organic method and by the resin method gave comparable typing results. Larger sample volume yielded a higher amount of DNA, but the typing rates were not affected for sample volumes between 1 and 5 ml. The quantifiable amounts of DNA present were found to be greater in female (14-200 ng/ml) than in male (4-60 ng/ml) samples and decreased with the elapsed time under both room temperature (RT) and frozen storage. Typing of the male samples also demonstrated that RT storage samples produced significantly higher success rates than that of frozen samples, while there was only marginal difference in the DNA typing rates among the conditions tested using female samples. Successful assignment of DQA1 + PM genotype was achieved for all samples of fresh urine, independent of gender, starting sample volume, or concentration method. Preservation by 0.25% sodium azide was acceptable for sample storage at 4 degrees C during a period of 30 days. For longer storage duration, freezing at -70 degrees C may be more appropriate. Thus, the applicability of the DQA1 + PM typing was clearly demonstrated for individualization of urine samples.

  3. Evaluation of the bioNexia Legionella Test, Including Impact of Incubation Time Extension, for Detection of Legionella pneumophila Serogroup 1 Antigen in Urine.

    PubMed

    Badoux, Paul; Euser, Sjoerd M; Bruin, Jacob P; Mulder, Patrick P G; Yzerman, Ed P F

    2017-06-01

    In this study, we compared the bioNexia test (bioMérieux, Marcy-l'Étoile, France), a new immunochromatographic assay for the detection of Legionella pneumophila serogroup 1 in urine, with the BinaxNOW urinary antigen test (Alere, Waltham, Massachusetts, USA). After 15 min of incubation (in accordance with the manufacturers' instructions), the sensitivities and specificities were, respectively, 76.5% and 97.2% for the bioNexia test and 87.1% and 100% for the BinaxNOW test. After a prolonged incubation time of 60 min, the sensitivities and specificities increased to, respectively, 89.4% and 97.2% for the bioNexia test and 91.8% and 100% for the BinaxNOW test. When the tests were read after 15 min, the concentration of discrepant urine samples increased the sensitivities to 94.1% for both tests. In conclusion, we found that although the bioNexia test showed lower sensitivity for the detection of L. pneumophila antigen in nonconcentrated urine compared to the BinaxNOW test, a prolonged incubation time as well as the use of concentrated samples showed comparable sensitivities for both tests. Copyright © 2017 American Society for Microbiology.

  4. Military Nutrition Research: Four Tasks to Address Personnel Readiness and Warfighter Performance

    DTIC Science & Technology

    2007-03-01

    insulin, free fatty acids, beta hydroxybutyrate, glucagon, and IGF-1, epinephrine, norepinephrine, urine creatinine, urine total nitrogen, urine urea...project. • Completion of blood testing for Project 4. Specifically, the following tests were completed: AST, beta hydroxybutyrate, blood urea...Minehira, J-M Schwarz, K Acheson, P Schneiter, J Burri, E Jequier, and L Tappy. Mechanisms of action of ß- glucan in postprandial glucose metabolism

  5. Clinical evaluation of Roche COBAS® AmpliPrep/COBAS® TaqMan® CMV Test using non-plasma samples.

    PubMed

    Hildenbrand, Cynthia; Wedekind, Laura; Li, Ge; vonRentzell, Jeanne E; Shah, Krunal; Rooney, Paul; Harrington, Amanda T; Zhao, Richard Y

    2018-05-24

    Cytomegalovirus (CMV) infection is a leading cause of loss of hearing, vision, and mental retardation in congenitally infected children. It is also associated with complications of organ-transplant and opportunistic HIV co-infection. The Roche COBAS ® AmpliPrep/COBAS ® TaqMan ® CMV Test is a FDA-approved test that measures CMV DNA viral load in plasma for the diagnosis and management of patients at risk for CMV-associated diseases. Besides plasma, CMV is often found in bronchoalveolar lavage (BAL), cerebrospinal fluid (CSF) and urine. Thus, monitoring of CMV for critical care of patients in these non-plasma samples becomes necessary. The objective of this study was to conduct an analytic and clinical feasibility study of the Roche CMV Test in BAL, CSF, and urine. The lower limit of detection (LOD), analytic measurement range (AMR), assay sensitivity, specificity, and precision were determined. Results of this study showed the LODs were 50, 100 and 300 IU/mL for BAL, CSF, or urine, respectively. The AMRs were from log 10 2.48 to log 10 5.48. The assay specificity was 94.4% for BAL, and 100% for CSF and urine. The assay precision was all within the acceptable range. The performance of Roche test was further compared with two comparators including the RealTime CMV Assay (Abbott Molecular) and a CMV Quantitative PCR Test (Vela Diagnostics). There was a general positive correlation between the Roche method and the Abbott or the Vela method. Overall, this study suggests the Roche CMV Test is suitable for the quantification of CMV viral load DNA in the described non-plasma samples. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  6. Use of ferric chloride to identify salicylate-containing poisons.

    PubMed

    Hoffman, Robert J; Nelson, Lewis S; Hoffman, Robert S

    2002-01-01

    Ferric chloride (FeCl3) is used to qualitatively test the urine of patients with presumed salicylate exposure. FeCl3 testing of an unidentified poison might provide evidence of salicylate exposure in situations where FeCl3 urine testing cannot be used. Such situations include the absence of a urine sample, immediately after ingestion before urine contains a detectable quantity of salicylate, or for patients chronically using salicylatesfor which FeCl3 testing is unhelpful. This study seeks to determine if FeCl3 can be used to identify salicylate-containing products. We assessed the reactivity of FeCl3 with commercially available salicylate-containing products. We applied 0.1 mL of 10% FeCl3 solution to each of 15 various salicylate-containing products including: regular and buffered acetylsalicylic acid, bismuth subsalicylate, methylsalicylate, physostigmine salicylate, salicylic acid, trolamine salicylate, and herbal tablets with salicin-containing white willow bark (Salix sp.). These products tested were: regular and enteric-coatedpills (n = 4), powder (n = 1), topical creams (n = 5), topical liquids (n = 4), and intravenous solution (n = 1). FeCl3 was applied to crushed tablets and added directly to liquids and creams. Fifteen salicylate-free controls including liquids, pills, and creams similar in appearance to experimental samples were also tested. Three blinded physiciansfamiliar with FeCl3 testing independently observed the addition of FeCl3 to each sample and rated a positive or negative result. All salicylate-containing products were interpreted to be clearly FeCl3 positive and all control samples were interpreted to be clearly FeCl3 negative. Salicylate-containing products may be identified using FeCl33. When using FeCl3

  7. The further development of the active urine collection device: a novel continence management system.

    PubMed

    Tinnion, E; Jowitt, F; Clarke-O'Neill, S; Cottenden, A M; Fader, M; Sutherland, I

    2003-01-01

    Continence difficulties affect the lives of a substantial minority of the population. Women are far more likely than men to be affected by urinary incontinence but the range of management options for them is limited. There has been considerable interest in developing an external urine collection system for women but without success to date. This paper describes the development and preliminary clinical testing of an active urine collection device (AUCD), which could provide a solution for sufferers. The device uses stored vacuum, protected by a high bubble point filter, to remove urine as quickly as it is produced. This allows a small battery-operated pump to provide the required vacuum, enabling the device to be portable. Two different types of non-invasive patient/device interface were developed, and tested by volunteers: urinal and small pad. The slimline urinal was popular with users although liquid noise was a problem. The pad interface was successful on occasions but further work is necessary to produce a reliable pad. This study has successfully demonstrated that a prototype AUCD liquid handling system can remove urine at clinically relevant flowrates. While further development is required, volunteer tests have shown that the AUCD could be a useful advance in continence management.

  8. Performance of a veterinary urine dipstick paddle system for diagnosis and identification of urinary tract infections in dogs and cats.

    PubMed

    Ybarra, Winnie L; Sykes, Jane E; Wang, Yenlie; Byrne, Barbara A; Westropp, Jodi L

    2014-04-01

    To evaluate the performance of a veterinary urine dipstick paddle (UDP) for diagnosis and identification of urinary tract infection (UTI) in dogs and cats. Prospective, randomized, blinded study. 207 urine specimens. UDPs were inoculated by 2 investigators and incubated according to manufacturer's instructions. Results, including presence or absence of bacterial growth, organism counts, and identification of uropathogens, were compared between investigators and with microbiology laboratory results. A subset of UDPs with bacterial growth was submitted to the laboratory for confirmation. The laboratory reported 64 (30.9%) specimens had growth of bacteria. Bacterial growth was reported for 63 (30.4%) and 58 (28.0%) of the UDPs by investigators 1 and 2, respectively. Sensitivity and specificity of the UDP for detection of bacterial growth were 97.3% and 98.6%, respectively, for investigator 1 and 89.1% and 99.3%, respectively, for investigator 2. For UPDs with ≥ 10(5) colony-forming units/mL, organism counts correlated well between the laboratory and investigators 1 (r = 0.95) and 2 (r = 0.89). Pathogen identification was not always accurate. Only 25 of 33 (75.8%) UDPs submitted for confirmation yielded bacteria consistent with those isolated from the original bacterial culture of urine. The veterinary UDP system was a sensitive test for screening patients for bacterial UTI, but uropathogen identification was not always accurate. When UDPs have bacterial growth, a fresh urine specimen should be submitted to the laboratory to confirm the identity of the organisms and to permit antimicrobial susceptibility testing.

  9. [Clinical usefulness of urine-formed elements' information obtained from bacteria detection by flow cytometry method that uses nucleic acid staining].

    PubMed

    Nakagawa, Hiroko; Yuno, Tomoji; Itho, Kiichi

    2009-03-01

    Recently, specific detection method for Bacteria, by flow cytometry method using nucleic acid staining, was developed as a function of automated urine formed elements analyzer for routine urine testing. Here, we performed a basic study on this bacteria analysis method. In addition, we also have a comparison among urine sediment analysis, urine Gram staining and urine quantitative cultivation, the conventional methods performed up to now. As a result, the bacteria analysis with flow cytometry method that uses nucleic acid staining was excellent in reproducibility, and higher sensitivity compared with microscopic urinary sediment analysis. Based on the ROC curve analysis, which settled urine culture method as standard, cut-off level of 120/microL was defined and its sensitivity = 85.7%, specificity = 88.2%. In the analysis of scattergram, accompanied with urine culture method, among 90% of rod positive samples, 80% of dots were appeared in the area of 30 degrees from axis X. In addition, one case even indicated that analysis of bacteria by flow cytometry and scattergram of time series analysis might be helpful to trace the progress of causative bacteria therefore the information supposed to be clinically significant. Reporting bacteria information with nucleic acid staining flow cytometry method is expected to contribute to a rapid diagnostics and treatment of urinary tract infections. Besides, the contribution to screening examination of microbiology and clinical chemistry, will deliver a more efficient solution to urine analysis.

  10. 75 FR 75485 - Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-03

    ... Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for Federal... Guidelines for Federal Workplace Drug Testing Programs (Mandatory Guidelines). The Mandatory Guidelines were... Laboratories and Instrumented Initial Testing Facilities (IITF) must meet in order to conduct drug and specimen...

  11. 75 FR 62842 - Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-13

    ... Current List of Laboratories Which Meet Minimum Standards To Engage in Urine Drug Testing for Federal... Guidelines for Federal Workplace Drug Testing Programs (Mandatory Guidelines). The Mandatory Guidelines were... and Instrumented Initial Testing Facilities (IITF) must meet in order to conduct drug and specimen...

  12. Urine Tests (For Parents)

    MedlinePlus

    ... a doctor suspects that a child has a urinary tract infection (UTI) or a health problem that can cause an ... to-Creatinine Ratio Kidney Diseases in Childhood Recurrent Urinary Tract Infections and Related Conditions Urinary Tract Infections Urine Test: ...

  13. Interpretation of Oral Fluid Tests for Drugs of Abuse

    PubMed Central

    CONE, EDWARD J.; HUESTIS, MARILYN A.

    2009-01-01

    Oral fluid testing for drugs of abuse offers significant advantages over urine as a test matrix. Collection can be performed under direct observation with reduced risk of adulteration and substitution. Drugs generally appear in oral fluid by passive diffusion from blood, but also may be deposited in the oral cavity during oral, smoked, and intranasal administration. Drug metabolites also can be detected in oral fluid. Unlike urine testing, there may be a close correspondence between drug and metabolite concentrations in oral fluid and in blood. Interpretation of oral fluid results for drugs of abuse should be an iterative process whereby one considers the test results in the context of program requirements and a broad scientific knowledge of the many factors involved in determining test outcome. This review delineates many of the chemical and metabolic processes involved in the disposition of drugs and metabolites in oral fluid that are important to the appropriate interpretation of oral fluid tests. Chemical, metabolic, kinetic, and analytic parameters are summarized for selected drugs of abuse, and general guidelines are offered for understanding the significance of oral fluid tests. PMID:17332074

  14. Smartphone-based analysis of biochemical tests for health monitoring support at home.

    PubMed

    Velikova, Marina; Smeets, Ruben L; van Scheltinga, Josien Terwisscha; Lucas, Peter J F; Spaanderman, Marc

    2014-09-01

    In the context of home-based healthcare monitoring systems, it is desirable that the results obtained from biochemical tests - tests of various body fluids such as blood and urine - are objective and automatically generated to reduce the number of man-made errors. The authors present the StripTest reader - an innovative smartphone-based interpreter of biochemical tests based on paper-based strip colour using image processing techniques. The working principles of the reader include image acquisition of the colour strip pads using the camera phone, analysing the images within the phone and comparing them with reference colours provided by the manufacturer to obtain the test result. The detection of kidney damage was used as a scenario to illustrate the application of, and test, the StripTest reader. An extensive evaluation using laboratory and human urine samples demonstrates the reader's accuracy and precision of detection, indicating the successful development of a cheap, mobile and smart reader for home-monitoring of kidney functioning, which can facilitate the early detection of health problems and a timely treatment intervention.

  15. Copper Is a Host Effector Mobilized to Urine during Urinary Tract Infection To Impair Bacterial Colonization.

    PubMed

    Hyre, Amanda N; Kavanagh, Kylie; Kock, Nancy D; Donati, George L; Subashchandrabose, Sargurunathan

    2017-03-01

    Urinary tract infection (UTI) is a major global infectious disease affecting millions of people annually. Human urinary copper (Cu) content is elevated during UTI caused by uropathogenic Escherichia coli (UPEC). UPEC upregulates the expression of Cu efflux genes during clinical UTI in patients as an adaptive response to host-derived Cu. Whether Cu is mobilized to urine as a host response to UTI and its role in protection against UTI remain unresolved. To address these questions, we tested the hypothesis that Cu is a host effector mobilized to urine during UTI to limit bacterial growth. Our results reveal that Cu is mobilized to urine during UTI caused by the major uropathogens Proteus mirabilis and Klebsiella pneumoniae , in addition to UPEC, in humans. Ceruloplasmin, a Cu-containing ferroxidase, is found at higher levels in UTI urine than in healthy control urine and serves as the molecular source of urinary Cu during UTI. Our results demonstrate that ceruloplasmin decreases the bioavailability of iron in urine by a transferrin-dependent mechanism. Experimental UTI with UPEC in nonhuman primates recapitulates the increased urinary Cu content observed during clinical UTI. Furthermore, Cu-deficient mice are highly colonized by UPEC, indicating that Cu is involved in the limiting of bacterial growth within the urinary tract. Collectively, our results indicate that Cu is a host effector that is involved in protection against pathogen colonization of the urinary tract. Because urinary Cu levels are amenable to modulation, augmentation of the Cu-based host defense against UTI represents a novel approach to limiting bacterial colonization during UTI. Copyright © 2017 American Society for Microbiology.

  16. Mutagenicity of urine from individuals exposed to LPG combustion products.

    PubMed

    Yin, X J; Liu, J Z; Kong, X H; Chu, J H; Wang, H; Xiao, Z X

    1998-09-01

    The mutagenicity of urine from individuals exposed to the combustion products of liquefied petroleum gas (LPG) was detected with Salmonella typhimurium TA98 and its newly developed derivatives YG1021 (nitroreductase overproducing) and YG1024 (O-acetyltransferase overproducing). The detection showed significantly increased mutagenicity for the two YG strains and increased positive rates for all three strains in the presence of both rat liver S9 and beta-glucuronidase. Further analysis demonstrated that urine samples taken from smoking and non-smoking exposed individuals exhibited significantly higher mutagenic potency (revertants/10 microliters urine concentrate) than their corresponding controls. These results indicate that the increased urine mutagenicity is caused by the exposure to LPG combustion products or smoking. The mutagenic potency of urine samples of all exposed individuals tested with YG1024 was found to be about 7 times higher than with TA98. The difference in mutagenic potency was smaller for the same samples when comparison was made between YG1021 and TA98. This suggests that the mutagenic compounds present in the urine samples contain mainly aromatic compounds as glucuronide conjugates. Our results demonstrate that YG1024 is more sensitive than TA98 in detecting the mutagenicity of these samples. In addition, no significant difference in the mutagenic potency between the 'pure' exposed (non-smokers') and the 'pure' smokers' (unexposed) samples was found in all three tester strains. This might mean that the exposure extent of mutagens/carcinogens in LPG combustion products for exposed individuals roughly corresponds to the smoking level of smokers who smoke 20-40 cigarettes per day. Furthermore, the results also suggest that synergism might exist in the mutagenic effects of exposure to LPG combustion products and cigarette smoking.

  17. 49 CFR 40.67 - When and how is a directly observed collection conducted?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.67 When and how is a... employee urinate into the collection container. Specifically, you are to watch the urine go from the...

  18. 49 CFR 40.67 - When and how is a directly observed collection conducted?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.67 When and how is a... employee urinate into the collection container. Specifically, you are to watch the urine go from the...

  19. 49 CFR 40.67 - When and how is a directly observed collection conducted?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.67 When and how is a... employee urinate into the collection container. Specifically, you are to watch the urine go from the...

  20. Blood in the Urine (Hematuria)

    MedlinePlus

    ... 2 weeks later to make sure the urine is free of red blood cells. If hematuria only happens once, there's usually ... follow-up tests to make sure your urine is free of red blood cells. If the hematuria goes away, your doctor ...

  1. The comparison of automated urine analyzers with manual microscopic examination for urinalysis automated urine analyzers and manual urinalysis.

    PubMed

    İnce, Fatma Demet; Ellidağ, Hamit Yaşar; Koseoğlu, Mehmet; Şimşek, Neşe; Yalçın, Hülya; Zengin, Mustafa Osman

    2016-08-01

    Urinalysis is one of the most commonly performed tests in the clinical laboratory. However, manual microscopic sediment examination is labor-intensive, time-consuming, and lacks standardization in high-volume laboratories. In this study, the concordance of analyses between manual microscopic examination and two different automatic urine sediment analyzers has been evaluated. 209 urine samples were analyzed by the Iris iQ200 ELITE (İris Diagnostics, USA), Dirui FUS-200 (DIRUI Industrial Co., China) automatic urine sediment analyzers and by manual microscopic examination. The degree of concordance (Kappa coefficient) and the rates within the same grading were evaluated. For erythrocytes, leukocytes, epithelial cells, bacteria, crystals and yeasts, the degree of concordance between the two instruments was better than the degree of concordance between the manual microscopic method and the individual devices. There was no concordance between all methods for casts. The results from the automated analyzers for erythrocytes, leukocytes and epithelial cells were similar to the result of microscopic examination. However, in order to avoid any error or uncertainty, some images (particularly: dysmorphic cells, bacteria, yeasts, casts and crystals) have to be analyzed by manual microscopic examination by trained staff. Therefore, the software programs which are used in automatic urine sediment analysers need further development to recognize urinary shaped elements more accurately. Automated systems are important in terms of time saving and standardization.

  2. Urine monitoring system failure analysis and operational verification test report

    NASA Technical Reports Server (NTRS)

    Glanfield, E. J.

    1978-01-01

    Failure analysis and testing of a prototype urine monitoring system (UMS) are reported. System performance was characterized by a regression formula developed from volume measurement test data. When the volume measurement test data. When the volume measurement data was imputted to the formula, the standard error of the estimate calculated using the regression formula was found to be within 1.524% of the mean of the mass of the input. System repeatability was found to be somewhat dependent upon the residual volume of the system and the evaporation of fluid from the separator. The evaporation rate was determined to be approximately 1cc/minute. The residual volume in the UMS was determined by measuring the concentration of LiCl in the flush water. Observed results indicated residual levels in the range of 9-10ml, however, results obtained during the flushing efficiency test indicated a residual level of approximately 20ml. It is recommended that the phase separator pumpout time be extended or the design modified to minimize the residual level.

  3. Repeated exposure to cat urine induces complex behavioral, hormonal, and c-fos mRNA responses in Norway rats ( Rattus norvegicus)

    NASA Astrophysics Data System (ADS)

    Yin, Baofa; Gu, Chen; Lu, Yi; Hegab, Ibrahim M.; Yang, Shengmei; Wang, Aiqin; Wei, Wanhong

    2017-08-01

    Prey species show specific adaptations that allow recognition, avoidance, and defense against predators. This study was undertaken to investigate the processing of a chronic, life-threatening stimulus to Norway rats ( Rattus norvegicus). One hundred forty-four Norway rats were tested by repeated presentation of cat urine for 1 h at different days in a defensive withdrawal apparatus. Rats exposed to urine for short periods showed significantly larger defensive behavioral and medial hypothalamic c-fos messenger RNA (mRNA) responses than other groups. These defensive responses habituated shortly after the presentation of cat urine. Serum levels of adrenocorticotropic hormone and corticosterone increased significantly when animals were repeatedly exposed to cat urine. However, the hormonal responses took longer to habituate than the behavioral and molecular responses did. We conclude that the behavioral and c-fos mRNA responses are "primed" for habituation to repeated exposures to cat urine, while the hormonal responses show "resistance." The results support our hypothesis that the strongest anti-predator responses at three levels would occur during short-term exposure to cat urine and that these responses would subsequently disappear on prolonged exposure. This study assists understanding the way in which the different levels of defensive responses are integrated and react during chronic stress.

  4. Repeated exposure to cat urine induces complex behavioral, hormonal, and c-fos mRNA responses in Norway rats (Rattus norvegicus).

    PubMed

    Yin, Baofa; Gu, Chen; Lu, Yi; Hegab, Ibrahim M; Yang, Shengmei; Wang, Aiqin; Wei, Wanhong

    2017-08-01

    Prey species show specific adaptations that allow recognition, avoidance, and defense against predators. This study was undertaken to investigate the processing of a chronic, life-threatening stimulus to Norway rats (Rattus norvegicus). One hundred forty-four Norway rats were tested by repeated presentation of cat urine for 1 h at different days in a defensive withdrawal apparatus. Rats exposed to urine for short periods showed significantly larger defensive behavioral and medial hypothalamic c-fos messenger RNA (mRNA) responses than other groups. These defensive responses habituated shortly after the presentation of cat urine. Serum levels of adrenocorticotropic hormone and corticosterone increased significantly when animals were repeatedly exposed to cat urine. However, the hormonal responses took longer to habituate than the behavioral and molecular responses did. We conclude that the behavioral and c-fos mRNA responses are "primed" for habituation to repeated exposures to cat urine, while the hormonal responses show "resistance." The results support our hypothesis that the strongest anti-predator responses at three levels would occur during short-term exposure to cat urine and that these responses would subsequently disappear on prolonged exposure. This study assists understanding the way in which the different levels of defensive responses are integrated and react during chronic stress.

  5. Urine testing for drugs of abuse: a survey of suburban parent-adolescent dyads.

    PubMed

    Schwartz, Richard H; Silber, Tomas J; Heyman, Richard B; Sheridan, Michael J; Estabrook, Dawn M

    2003-02-01

    The American Academy of Pediatrics is opposed to involuntary diagnostic testing for drugs of abuse. To gather data about attitudes of parents and their teenagers about involuntary drug testing on parental request. Adolescents and their accompanying parents separately answered a printed survey in the offices of their private pediatrician. The survey posed 2 hypothetical questions about urine testing: (1) Do parents have the right to ask a teenager's physician to order a urine test for drugs of abuse without the teenager's knowledge-if the teenager has falling school grades, an uncooperative attitude, and major untruthfulness? (2) In such a case, should the teenager's physician obtain a urine test for drugs on parental request only, without the teenager's consent? A total of 393 paired evaluable surveys were collected: 77.6% from Virginia and 22.4% from Ohio. There were no significant differences in answers between the 2 study sites. Of the students, 85.8% had either an A or a B grade point average. Current marijuana use was unusually low in our teenaged respondents. Of the parents surveyed, 81.7% would want a physician to be able to perform a urine test for drugs of abuse for a problematic teenager without the young person's consent. The answers to the 2 questions about urine drug tests had poor kappa coefficients of agreement between teenagers and parents (0.04 and 0.09, respectively). Reanalysis, using the variables of age, grade point average, and frequency of marijuana smoking, showed little difference in agreement scores. In the 2 suburban pediatric practices surveyed, parental opinions and expectations were at variance with the American Academy of Pediatrics policy statement on nonconsensual urine drug testing in the presence of clinical problems. Pediatricians need to be conscious of this clinical-ethical dilemma, become familiar with the American Academy of Pediatrics policy on drug testing, and develop their own position and expertise in this area. The dyad method (parent-teenager survey) is novel and improved the methodology of our study. We surveyed middle-class suburban adolescents while previous studies of adolescents surveyed inner-city populations.

  6. 10 CFR 26.5 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...

  7. 10 CFR 26.5 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...

  8. 10 CFR 26.5 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...

  9. 10 CFR 26.5 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...

  10. 10 CFR 26.5 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...

  11. Selecting accurate post-elimination monitoring tools to prevent reemergence of urogenital schistosomiasis in Morocco: a pilot study.

    PubMed

    Balahbib, Abdelaali; Amarir, Fatima; Corstjens, Paul L A M; de Dood, Claudia J; van Dam, Govert J; Hajli, Amina; Belhaddad, Meryem; El Mansouri, Bouchra; Sadak, Abderrahim; Rhajaoui, Mohamed; Adlaoui, El Bachir

    2017-04-06

    After alleged stop of transmission of schistosomiasis and further down the line in post elimination settings, sensitive tools are required to monitor infection status to prevent potential re-emergence. In Rahala, where transmission cycle of Schistosoma haematobium is interrupted since 2004 but where 30% of snails are still infected by S. bovis, potential human S. bovis infection can't be excluded. As methods based on egg-counts do not provide the required sensitivity, antibody or antigen assays are envisaged as the most appropriate tools for this type of monitoring. In this pilot study, the performances of three assays were compared: two commercially available antibody tests (ELISA and haemagglutination format) indicating exposure, and an antigen test (lateral flow strip format) demonstrating active infection. All 37 recruited study participants resided in Rahala (Akka, province Tata, Morocco). Participants had been diagnosed and cured from schistosomiasis in the period between 1983 and 2003. In 2015 these asymptomatic participants provided fresh clinical samples (blood and urine) for analysis with the aforementioned diagnostics tests. No eggs were identified in the urine of the 37 participants. The haemagglutination test indicated 6 antibody positives whereas the ELISA indicated 28 antibody positives, one indecisive and one false positive. ELISA and haemagglutination results matched for 18 individuals, amongst which 5 out of 6 haemagglutination positives. With the antigen test (performed on paired serum and urine samples), serum from two participants (cured 21 and 32 years ago) indicated the presence of low levels of the highly specific Schistosoma circulating anodic antigen (CAA), demonstrating low worm level infections (less than 5 pg/ml corresponding to probably single worm pair). One tested also CAA positive with urine. ELISA indicated the presence of human anti-Schistosoma antibodies in these two CAA positive cases, haemagglutination results were negative. To prevent reemergence of schistosomiasis in Morocco current monitoring programs require specific protocols that include testing of antibody positives for active infection by the UCP-LF CAA test, the appropriate diagnostic tool to identify Schistosoma low grade infections in travelers, immigrants and assumed cured cases. The test is genus specific will also identify infections related to S. bovis.

  12. Higher urine 1-hydroxy pyrene glucuronide (1-OHPG) is associated with tobacco smoke exposure and drinking maté in healthy subjects from Rio Grande do Sul, Brazil

    PubMed Central

    Fagundes, Renato B; Abnet, Christian C; Strickland, Paul T; Kamangar, Farin; Roth, Mark J; Taylor, Philip R; Dawsey, Sanford M

    2006-01-01

    Background The highest rates of esophageal squamous cell carcinoma (ESCC) in Brazil occur in Rio Grande do Sul, the most southern state, which has incidence rates of 20.4/100,000/year for men and 6.5/100,000/year for women. Exposure to carcinogenic polycyclic aromatic hydrocarbons (PAHs) through tobacco smoke and other sources may increase the risk of ESCC. The aims of the current study were to investigate the degree and sources of PAH exposure of the inhabitants of this region of southern Brazil. Methods Two hundred healthy adults (half smokers, half non smokers, half male and half female) were recruited, given a standardized questionnaire, and asked to provide a urine sample for measurement of 1-hydroxypyrene glucuronide (1-OHPG), a PAH metabolite). Urine 1-OHPG concentrations were measured using immunoaffinity chromatography and synchronous fluorescence spectroscopy and urine cotinine was measured using a dipstick test. We examined factors associated with 1-OHPG concentration using Wilcoxon tests and multiple linear regression. Results Urine 1-hydroxypyrene glucuronide (1-OHPG) was successfully measured on 199 subjects. The median (interquartile range) of urine 1-OHPG in the 199 participants was 2.09 pmol/mL (0.51, 5.84). Tobacco smoke exposure and maté drinking were statistically significantly associated with higher urine 1-OHPG concentrations in the multivariate linear regression model. Conclusion Tobacco smoke and maté both contribute to high levels of benzo[a]pyrene exposure in the people of southern Brazil. This high PAH exposure may contribute to the high rates of ESCC observed in this population. The increased urine 1-OHPG concentrations associated with maté suggest that contaminants, not just thermal injury, may help explain the increased risk of ESCC previously reported for maté consumption. PMID:16729889

  13. International Space Station Urine Monitoring System Functional Integration and Science Testing

    NASA Technical Reports Server (NTRS)

    Rodriguez, Branelle R.; Broyan, James Lee, Jr.

    2008-01-01

    Exposure to microgravity during human spaceflight is required to be defined and understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Urine voids are capable of measuring the calcium and other metabolic byproducts in a constituent s urine. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross contamination (<0.7 ml urine) and has volume accuracy of +/-2% between 100 to 1000 ml urine voids.

  14. International Space Station Urine Monitoring System Functional Integration and Science Testing

    NASA Technical Reports Server (NTRS)

    Cibuzar, Branelle R.; Broyan, James Lee, Jr.

    2009-01-01

    Exposure to microgravity during human spaceflight is required to be defined and understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Urine voids are capable of measuring the calcium and other metabolic byproducts in a constituent s urine. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross contamination (<0.7 ml urine) and has volume accuracy of +/-2% between 100 to 1000 ml urine voids.

  15. Changes observed in urine microbiology following replacement of long-term urinary catheters: need to modify UTI guidelines in the UK?

    PubMed

    Batura, Deepak; Gopal Rao, G; Foran, Marion; Brempong, Fatmata

    2018-01-01

    Bacteria adherent to long-term urinary catheters (LTUC) may give misleading urine culture results. Guidelines in the USA recommend changing LTUC before urine collection to diagnose UTI and before commencing appropriate antimicrobial treatment. However, in the UK there is no such guidance. In this study, we evaluated differences in urine cultures before and after changing LTUC. In a prospective study in a UK urology department, we made a quantitative and qualitative comparison between paired urines collected before and after catheter change in patients with LTUC. We measured culture growth on a four-point ordinal scale as nil, scanty (< 10 7  cfu/L), moderate (10 7 -10 8  cfu/L) or heavy (> 10 8  cfu/L) and recorded the range of bacterial species isolated. Statistical analysis was by Wilcoxon matched-pairs test. Sixty-six patients (55 males, 11 females) took part in the study. Urines with no growth increased from 7/66 (11%) before change of catheter to 21/66(32%) after change of catheter. Cultures reported as heavy growth (> 10 8  cfu/L) reduced from 48/66 (73%) to 25/66 (38%) after catheter change (p < 0.001). Except for Pseudomonas spp., other organisms were isolated less frequently after catheter change. No Proteus spp. was isolated after catheter change. This study confirms that failure to change long-term catheters before collecting urine for culture may give misleading results. In the interest of accurate diagnosis and antimicrobial stewardship, UK guidelines should recommend changing long-term urinary catheters before collection of urine for culture.

  16. Determination of 3-hydroxypropylmercapturic acid in urine by three column-switching high-performance liquid chromatography with electrochemical detection using a diamond electrode.

    PubMed

    Higashi, Kyohei; Shibasaki, Mana; Kuni, Kyoshiro; Uemura, Takeshi; Waragai, Masaaki; Uemura, Kenichi; Igarashi, Kazuei; Toida, Toshihiko

    2017-09-29

    A three column-switching high-performance liquid chromatography (HPLC) using an electrochemical detector (ECD) equipped with a diamond electrode was established to determine 3-hydroxypropylmercapturic acid (3-HPMA) in urine. An extracted urine sample was consecutively fractionated using a strong anion-exchange column (first column) and a C8 column (second column) via a switching valve before application on an Octa Decyl Silyl (ODS) column (third column), followed by ECD analysis. The% recovery of 3-HPMA standard throughout the three-column process and limit of detection (LOD) were 94±1% and 0.1pmol, respectively. A solid phase extraction step is required for the sensitive analysis of 3-HPMA in urine by column-switching HPLC-ECD despite a decreased% recovery (55%) of urine sample spiked with 100pmol of 3-HPMA. To test the utility of our column-switching HPLC-ECD method, 3-HPMA levels of 27 urine samples were determined, and the correlation between HPLC-ECD and LC-Electrospray ionization (ESI)-MS/MS method was examined. As a result, the median values of μmol 3-HPMA/g Creatinine (Cre) in urine obtained by column-switching HPLC-ECD and LC-MS/MS were 2.19±2.12μmol/g Cre and 2.13±3.38μmol/g Cre, respectively, and the calibration curve (y=1.5171x-1.007) exhibited good linearity within a defined range (r 2 =0.907). These results indicate that the combination of column-switching HPLC and ECD is a powerful tool for the specific, reliable detection of 3-HPMA in urine. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Human urine as test material in 1H NMR-based metabonomics: recommendations for sample preparation and storage.

    PubMed

    Lauridsen, Michael; Hansen, Steen H; Jaroszewski, Jerzy W; Cornett, Claus

    2007-02-01

    Metabonomic approaches are believed to have the capability of revolutionizing diagnosis of diseases and assessment of patient conditions after medical interventions. In order to ensure comparability of metabonomic 1H NMR data from different studies, we suggest validated sample preparation guidelines for human urine based on a stability study that evaluates effects of storage time and temperature, freeze-drying, and the presence of preservatives. The results indicated that human urine samples should be stored at or below -25 degrees C, as no changes in the 1H NMR fingerprints have been observed during storage at this temperature for 26 weeks. Formation of acetate, presumably due to microbial contamination, was occasionally observed in samples stored at 4 degrees C without addition of a preservative. Addition of a preserving agent is not mandatory provided that the samples are stored at -25 degrees C. Thus, no differences were observed between 1H NMR spectra of nonpreserved urines and urines with added sodium azide and stored at -25 degrees C, whereas the presence of sodium fluoride caused a shift of especially citrate resonances. Freeze-drying of urine and reconstitution in D2O at pH 7.4 resulted in the disappearance of the creatinine CH2 signal at delta 4.06 due to deuteration. A study evaluating the effects of phosphate buffer concentration on signal variability and assessment of the probability of citrate or creatinine resonances crossing bucket border (a boundary between adjacent integrated regions) led to the conclusion that a minimum buffer concentration of 0.3 M is adequate for normal urines used in this study. However, final buffer concentration of 1 M will be required for very concentrated urines.

  18. The effect of boric acid on bacterial culture of canine and feline urine.

    PubMed

    Rowlands, M; Blackwood, L; Mas, A; Cripps, P; Crompton, C; Burrow, R

    2011-10-01

    To identify the optimal method of submission of canine and feline urine for bacterial culture. Cystocentesis samples from 250 animals (200 dogs, 50 cats) suspected of having urinary tract infections were collected. The reference aliquot, without preservative, was processed on site within 2 hours. Two further aliquots (one without preservative, one with boric acid) were stored at room temperature for up to 7 hours and then posted by guaranteed next day delivery to a commercial laboratory for analysis. Forty-seven of the samples were positive on culture in the reference test. There was no significant difference between reference test results and those of samples posted without preservative (P=0·39), but samples posted in boric acid were significantly less likely to give a positive result (P=0·01). Samples posted without preservative had a sensitivity of 82% and a specificity of 98%; for boric acid, sensitivity was 73% and specificity 99%. Postal urine samples should be submitted to the laboratory in a plain sterile tube. © 2011 British Small Animal Veterinary Association.

  19. Mucus in Urine: MedlinePlus Lab Test Information

    MedlinePlus

    ... is normal. An excess amount may indicate a urinary tract infection (UTI) or other medical condition. A test called urinalysis ... your urinalysis if you have symptoms of a UTI. These include: Frequent urge to urinate, but little ...

  20. Evaluation of the performance of Human Papillomavirus testing in paired urine and clinician-collected cervical samples among women aged over 30 years in Bhutan.

    PubMed

    Tshomo, Ugyen; Franceschi, Silvia; Tshokey, Tshokey; Tobgay, Tashi; Baussano, Iacopo; Tenet, Vanessa; Snijders, Peter J F; Gheit, Tarik; Tommasino, Massimo; Vorsters, Alex; Clifford, Gary M

    2017-04-08

    Urine sampling may offer a less invasive solution than cervical sampling to test for human papillomavirus (HPV) for HPV vaccine impact monitoring. Paired samples of urine and exfoliated cervical cells were obtained for 89 women with history of high-risk (HR) HPV-positive normal cytology in Bhutan. Urine sampling protocol included self-collection of first-void urine immediately into a conservation medium and procedures to optimize DNA yield. Colposcopical abnormalities were biopsied. Two HPV assays were used: a multiplex type-specific PCR (E7-MPG) and a less analytically sensitive GP5+/6+ PCR followed by reverse line blot. HPV positivity for 21 types common to both assays was similar in urine and cells by E7-MPG (62.9% and 57.3%, respectively, p = 0.32) but lower in urine by GP5+/6+ (30.3% and 40.4%, p = 0.05). HPV6/11/16/18 positivity did not significantly differ between urine and cells by either assay. Sensitivity of urine (using cells as gold standard) to detect 21 HPV types was 80% and 58% for E7-MPG and GP5+/6+, respectively, with specificity 61% and 89%. HPV type distribution in urine and cells was similar, regardless of assay. The 5 detected CIN3+ were HR-HPV positive in cells by both assays, compared to 4 and 3 by E7-MPG and GP5+/6+, respectively, in urine samples. For the monitoring of vaccine impact, we demonstrate validity of a urine sampling protocol to obtain HPV prevalence data that are broadly comparable to that from cervical cells. However, detection of HPV in urine varies according to assay sensitivity, presumably because low level infections are frequent.

  1. Reagent strip testing is not sensitive for the screening of asymptomatic bacteriuria in pregnant women.

    PubMed

    Lumbiganon, Pisake; Chongsomchai, Chompilas; Chumworathayee, Bundit; Thinkhamrop, Jadsada

    2002-08-01

    The objective of the study was to assess the diagnostic performance of the reagent strip in screening for asymptomatic bacteriuria in pregnant women using urine culture as a gold standard. This study comprised 204 asymptomatic pregnant women who attended their first antenatal care at Srinagarind Hospital, Khon Kaen University from April 1, 1999 to June 30, 1999. Women with symptoms of urinary tract infection, antibiotic treatment within the previous 7 days, pregnancy-induced hypertension, bleeding per vagina and history of urinary tract diseases were excluded. Urine specimens were collected by clean catched midstream urine technique for urinalysis, reagent strip test and urine culture. Diagnostic performance of reagent strip in terms of sensitivity, specificity, positive and negative predictive value was analyzed. Urine reagent strip test had a sensitivity of 13.9 per cent, a specificity of 95.6 per cent, a positive predictive value of 46.1 per cent, a negative predictive value of 80.6 per cent in detecting asymptomatic bacteriuria in pregnant women.

  2. Unreliable alcohol testing in a shipping safety programme.

    PubMed

    Helander, Anders; Hagelberg, Charlotte Asker; Beck, Olof; Petrini, Björn

    2009-08-10

    Within a maritime alcohol and drug testing programme, a case showing an unphysiological urine ethanol concentration (235 mmol/L, 10.8 g/L) was found. The sample contained low levels of the ethanol metabolites ethyl glucuronide (EtG) and ethyl sulphate (EtS) which confirmed prior drinking, but also tested positive for the fermenting yeast Candida albicans which suggested post-sampling ethanol formation. This and other questionable cases prompted investigation of the suitability of urine alcohol testing for the intended application. Besides the routine measurements of ethanol, illicit drugs and creatinine, randomly selected ethanol-positive and ethanol-negative urines collected within the maritime programme were checked for the presence of EtG and EtS and for fungal and bacterial growth. Data on sample handling and storage was also gathered. Ten of 15 (67%) ethanol-positive and 4 of 9 (44%) ethanol-negative urines contained yeast and/or bacteria. Among the ethanol-positive cases, 4 (27%) were obviously false positives because EtG and EtS were not detected. Microbial action as the reason for false-high ethanol concentrations was indicated in other cases. When 17 bacteria-infected but fungi-negative urines were supplemented with glucose and stored for 1 week at 21 degrees C, ethanol was formed in 2 specimens containing Escherichia coli and E. coli plus P. aeruginosa. In these samples, EtG was also formed on storage while EtS was not. The routines employed for urine collection and handling within this substance abuse programme caused many false-positive identifications of alcohol use with unintended medico-legal consequences. Unpreserved urines stored without cooling should not be used for alcohol testing, given the high risk for microbial interference.

  3. Human Excretion of Bisphenol A: Blood, Urine, and Sweat (BUS) Study

    PubMed Central

    Genuis, Stephen J.; Beesoon, Sanjay; Birkholz, Detlef; Lobo, Rebecca A.

    2012-01-01

    Background. Bisphenol A (BPA) is an ubiquitous chemical contaminant that has recently been associated with adverse effects on human health. There is incomplete understanding of BPA toxicokinetics, and there are no established interventions to eliminate this compound from the human body. Using 20 study participants, this study was designed to assess the relative concentration of BPA in three body fluids—blood, urine, and sweat—and to determine whether induced sweating may be a therapeutic intervention with potential to facilitate elimination of this compound. Methods. Blood, urine, and sweat were collected from 20 individuals (10 healthy participants and 10 participants with assorted health problems) and analyzed for various environmental toxicants including BPA. Results. BPA was found to differing degrees in each of blood, urine, and sweat. In 16 of 20 participants, BPA was identified in sweat, even in some individuals with no BPA detected in their serum or urine samples. Conclusions. Biomonitoring of BPA through blood and/or urine testing may underestimate the total body burden of this potential toxicant. Sweat analysis should be considered as an additional method for monitoring bioaccumulation of BPA in humans. Induced sweating appears to be a potential method for elimination of BPA. PMID:22253637

  4. Identification of leptospiral 3-hydroxyacyl-CoA dehydrogenase released in the urine of infected hamsters

    PubMed Central

    2014-01-01

    Background Leptospirosis is a global zoonosis caused by pathogenic Leptospira. The non-specific clinical signs and symptoms of leptospirosis lead to its misdiagnosis. To date, there is still no reliable rapid test kit that can accurately diagnose leptospirosis at bedside or in field. In this research, with the ultimate goal of formulating a rapid and accurate diagnostic tool for leptospirosis, we aimed to identify leptospiral proteins excreted in urine of infected hamsters, which are thought to mimic Weil’s disease. Results Hamsters were subcutaneously infected with leptospires, and the general attributes of urine as well as the proteins excreted in it were examined. Some leptospiral proteins were found to be excreted in the urine from the early phase of infection. The most important finding of this study was the detection of the lipid-metabolizing enzyme, 3-hydroxyacyl-CoA dehydrogenase (HADH), before the onset of illness, when leptospires were not yet detected in the urine of infected hamsters. Conclusions This is the first report on the detection of leptospiral HADH in the host urine, which may be a possible candidate leptospiral antigen that can be used in the early diagnosis of human and animal leptospirosis. PMID:24884439

  5. Fluid control mechanisms in weightlessness

    NASA Technical Reports Server (NTRS)

    Leach, Carolyn S.

    1987-01-01

    Experiments performed on Space Shuttle flights have emphasized study of the earliest effects of the cephalad fluid shift resulting from microgravity. Analysis of one subject's urine collected during flight showed that a sharp increase in antidiuretic hormone occurred within 2 h of launch, followed by an increase in cortisol excretion. Although this subject had symptoms of the space adaptation syndrome (SAS), inflight data from Spacelab missions suggested that these transient changes were not caused by SAS. Unpaired t-tests and Mann-Whitney tests showed that before and after flight, plasma thyroxine and urine osmolality were significantly higher in Shuttle crewmembers who exhibited more severe symptoms of SAS than in asymptomatic crewmembers.

  6. Beating the urine drug test - a case report on niacin toxicity.

    PubMed

    Fayyaz, Beenish; Rehman, Hafiz J; Upreti, Sunita

    2018-01-01

    Niacin is a form of vitamin B3 which is used for the medical treatment of hyperlipidemia and niacin deficiency. However, within the last few years, it is being advertised on the Internet as a quick way to detoxify the human body in an attempt to evade urine drug tests. This claim is without any medical or scientific evidence and as a result, many cases have been reported where young adults have ended up with niacin toxicity. In this case report, we discuss a rare presentation of niacin toxicity and the effects Internet has had on the healthcare being practised by both the physicians and the patients themselves.

  7. Active and realistic passive marijuana exposure tested by three immunoassays and GC/MS in urine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mule, S.J.; Lomax, P.; Gross, S.J.

    Human urine samples obtained before and after active and passive exposure to marijuana were analyzed by immune kits (Roche, Amersham, and Syva) and gas chromatography/mass spectrometry (GC/MS). Seven of eight subjects were positive for the entire five-day test period with one immune kit. The latter correlated with GC/MS in 98% of the samples. Passive inhalation experiments under conditions likely to reflect realistic exposure resulted consistently in less than 10 ng/mL of cannabinoids. The 10-100-ng/mL cannabinoid concentration range essential for detection of occasional and moderate marijuana users is thus unaffected by realistic passive inhalation.

  8. Evaluation of urine for Leishmania infantum DNA detection by real-time quantitative PCR.

    PubMed

    Pessoa-E-Silva, Rômulo; Mendonça Trajano-Silva, Lays Adrianne; Lopes da Silva, Maria Almerice; da Cunha Gonçalves-de-Albuquerque, Suênia; de Goes, Tayná Correia; Silva de Morais, Rayana Carla; Lopes de Melo, Fábio; de Paiva-Cavalcanti, Milena

    2016-12-01

    The availability of some sorts of biological samples which require noninvasive collection methods has led to an even greater interest in applying molecular biology on visceral leishmaniasis (VL) diagnosis, since these samples increase the safety and comfort of both patients and health professionals. In this context, this work aimed to evaluate the suitability of the urine as a specimen for Leishmania infantum kinetoplast DNA detection by real-time quantitative PCR (qPCR). Subsequent to the reproducibility analysis, the detection limit of the qPCR assay was set at 5fg (~0.025 parasites) per μL of urine. From the comparative analysis performed with a set of diagnostic criteria (serological and molecular reference tests), concordance value of 96.08% was obtained (VL-suspected and HIV/AIDS patients, n=51) (P>0.05). Kappa coefficient (95% CI) indicated a good agreement between the test and the set of diagnostic criteria (k=0.778±0.151). The detection of Leishmania DNA in urine by qPCR was possible in untreated individuals, and in those with or without suggestive renal impairment. Fast depletion of the parasite's DNA in urine after treatment (from one dose of meglumine antimoniate) was suggested by negative qPCR results, thus indicating it as a potential alternative specimen to follow up the efficacy of therapeutic approaches. Even when evaluated in a clinically heterogeneous set of patients, the urine showed good prospect as sample for VL diagnosis by qPCR, also indicating a good negative predictive value for untreated suspected patients. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Development of Urine Receptacle Assembly for the Crew Exploration Vehicle

    NASA Technical Reports Server (NTRS)

    Cibuzar, Branelle Rae; Thomas, Evan; Peterson, Laurie; Goforth, Johanna

    2008-01-01

    The Urine Receptacle Assembly (URA) initially was developed for Apollo as a primary means of urine collection. The aluminum housing with stainless steel honeycomb insert provided all male crewmembers with a non-invasive means of micturating into a urine capturing device and then venting to space. The performance of the URA was a substantial improvement over previous devices but its performance was not well understood. The Crew Exploration Vehicle (CEV) program is exploring the URA as a contingency liquid waste management system for the vehicle. URA improvements are required to meet CEV requirements, including: consumables minimization, flow performance, acceptable hygiene standards, crew comfort, and female crewmember capability. This paper presents the results of a historical review of URA performance during the Apollo program, recent URA performance tests on the reduced gravity aircraft flight under varying flow conditions, and a proposed development plan for the URA to meet CEV needs.

  10. Stability of Zika virus in urine: Specimen processing considerations and implications for the detection of RNA targets in urine.

    PubMed

    Tan, Susanna K; Sahoo, Malaya K; Milligan, Stephen B; Taylor, Nathaniel; Pinsky, Benjamin A

    2017-10-01

    Detection of Zika virus (ZIKV) RNA in urine is of increasing interest for the diagnosis of ZIKV infection. Pre-analytical variables can significantly impact the stability of RNA in urine. To determine optimal specimen processing protocols that would maximize detection of ZIKV RNA in urine by real-time, reverse transcriptase PCR, we investigated the effect of temperature, initial ZIKV concentration, use of nucleic acid stabilizers, and time on ZIKV RNA levels. Urine samples from healthy donors were spiked with ZIKV using the Exact Diagnostics ® ZIKV Verification Panel, a commercially available panel composed of heat-inactivated ZIKV, at concentrations of 5.0 log 10 copies/mL (ZIKV-high) and 4.0 log 10 copies/mL (ZIKV-low). Samples were stored at room temperature, 4°C, or -80°C and frozen aliquots were exposed to no stabilizer (urine), Buffer ATL (Qiagen, Germantown, MD), or DNA/RNA Shield (Zymo Research, Irvine, CA). ZIKV RNA levels in urine declined steadily at room temperature, though was not significant by 48h (ZIKV-high, p=0.09; ZIKV-low, p=0.20). ZIKV RNA titers were consistently higher when stored at 4°C, suggesting that storage at 4°C can slow the progression of RNA degradation. Freezing urine samples at -80°C resulted in a significant loss of detectable ZIKV RNA in the ZIKV-low group. ZIKV RNA was detected in 5/6 replicates at 3days, 1/6 replicates at 10days, and 1/3 replicates at 30days, with findings reproducible on repeat testing. Presence of either nucleic acid stabilizer in urine corrected this effect, and resulted in recovery of ZIKV RNA in all replicates. Use of a nucleic acid stabilizer in the ZIKV-high group did not add incremental benefit for the detection or quantitation of ZIKV RNA. ZIKV RNA is prone to degradation in urine with loss of detectable virus even when specimens are frozen at -80°C for 10days. Detection of ZIKV-positive urine samples, particularly those containing low ZIKV titers may be aided with the addition of a nucleic acid stabilizer during urine specimen processing. Copyright © 2017. Published by Elsevier B.V.

  11. Correlation between urodynamic tests, history and clinical findings in treatment of women with urinary incontinence.

    PubMed

    Borges, João Bosco Ramos; Guarisi, Telma; Camargo, Ana Carolina Marchesini de; Borges, Pítia Cárita de Godoy

    2010-12-01

    The aim of this study was to evaluate the role of urodynamic test in diagnosis of urinary incontinence, comparing detailed data of history and physical examination, and some easy- to-apply clinical tests. A cross-sectional retrospective study was carried out by reviewing the medical charts of 55 patients with complaint of loss of urine, seen at the Urogynecology Service of Women's Health Outpatient Clinic of Hospital Universitário de Jundiaí, between October 2006 and March 2007. The patients answered a specific questionnaire involving the epidemiological and physical examination variables considered in this study. They were submitted to physical examination and urodynamic tests. The complaint of loss of urine upon exertion, either isolated or associated with urge incontinence, was confirmed by urodynamic tests in most women, and only 4 of 49 symptomatic women had negative results. The clinical sign was present in 35 patients (63.6%), and 46 patients (83.6%) had the exertion component in the urodynamic test. The exertion component was observed in 10 (18%) out of 15 patients without symptoms (30%). The positive and negative predictive values of the clinical sign for diagnosis of any type of urinary incontinence in this studied group were 97.1 and 26.7%, respectively. As for the clinical complaint of urinary loss upon exertion, the positive and negative predictive values for any type of urinary incontinence were 92 and 40%, respectively. For the clinical complaint of urge incontinence, the positive and negative predictive values of 92.5 and 23.1%, respectively. It was concluded that the urodynamic evaluation is an important instrument to evaluate the severity of incontinence, although it was not necessary to diagnose loss of urine. The finding of urinary loss during physical examination had low sensitivity and specificity in diagnosis of the type of loss of urine. Urodynamic tests had better performance in demonstrating urinary incontinence in patients with complaint of incontinence upon exertion and without loss of urine seen upon physical examination than in confirming urge incontinence in patients with those symptoms.

  12. Direct Detection and Genotyping of Klebsiella pneumoniae Carbapenemases from Urine by Use of a New DNA Microarray Test

    PubMed Central

    Peter, Harald; Berggrav, Kathrine; Thomas, Peter; Pfeifer, Yvonne; Witte, Wolfgang; Templeton, Kate

    2012-01-01

    Klebsiella pneumoniae carbapenemases (KPCs) are considered a serious threat to antibiotic therapy, as they confer resistance to carbapenems, which are used to treat extended-spectrum beta-lactamase (ESBL)-producing bacteria. Here, we describe the development and evaluation of a DNA microarray for the detection and genotyping of KPC genes (blaKPC) within a 5-h period. To test the whole assay procedure (DNA extraction plus a DNA microarray assay) directly from clinical specimens, we compared two commercial DNA extraction kits (the QIAprep Spin miniprep kit [Qiagen] and the urine bacterial DNA isolation kit [Norgen]) for the direct DNA extraction from urine samples (dilution series spiked in human urine). Reliable single nucleotide polymorphism (SNP) typing was demonstrated using 1 × 105 CFU/ml urine for Escherichia coli (Qiagen and Norgen) and 80 CFU/ml urine, on average, for K. pneumoniae (Norgen). This study presents, for the first time, the combination of a new KPC microarray with commercial sample preparation for detecting and genotyping microbial pathogens directly from clinical specimens; this paves the way toward tests providing epidemiological and diagnostic data, enabling better antimicrobial stewardship. PMID:23035190

  13. A rare case of renal infarction caused by infective endocarditis.

    PubMed

    Zakaria, Rasheed; Forsyth, Vhari; Rosenbaum, Tomas

    2009-10-01

    A 29-year-old man presented to the emergency department of a general hospital complaining of sudden onset left loin pain, radiating to the groin, which had started 48 h previously. He described no urological symptoms and had no medical history of note. Physical examination, electrocardiography, dipstick testing of urine, radiography of the chest and abdomen, blood tests (white blood cell count and serum urea, creatinine, sodium, potassium and C-reactive protein levels), CT of the renal tract, blood and urine cultures, renal angiography, thromboembolic blood panel, urine and blood tests for illicit drugs, transthoracic echocardiography, transesophageal echocardiography, renal ultrasonography. Infective endocarditis resulting in thromboembolic unilateral renal infarction. The patient was started on anticoagulation therapy with low-molecular-weight heparin and treated with intravenous gentamicin and benzylpenicillin for 4 weeks. He was seen in an outpatient clinic 4 weeks after discharge, at which time serum urea and creatinine levels and repeat ultrasonography of the renal tract confirmed normal renal function. He will be followed up regularly by cardiologists and urologists, at 6 weeks initially, and every 6 months to 1 year thereafter by his family physician.

  14. Life Testing of the Vapor Compression Distillation/Urine Processing Assembly (VCD/UPA) at the Marshall Space Flight Center (1993 to 1997)

    NASA Technical Reports Server (NTRS)

    Wieland, P.; Hutchens, C.; Long, D.; Salyer, B.

    1998-01-01

    Wastewater and urine generated on the International Space Station will be processed to recover pure water using vapor compression distillation (VCD). To verify the long-term reliability and performance of the VCD Urine Processor Assembly (UPA), life testing was performed at the Marshall Space Flight Center (MSFC) from January 1993 to April 1996. Two UPA'S, the VCD-5 and VCD-5A, were tested for 204 days and 665 days, respectively. The compressor gears and the distillation centrifuge drive belt were found to have operating lives of approximately 4,800 hours, equivalent to 3.9 years of operation on ISS for a crew of three at an average processing rate of 1.76 kg/h (3.97 lb/h). Precise alignment of the flex-splines of the fluids and purge pump motor drives is essential to avoid premature failure after about 400 hours of operation. Results indicate that, with some design and procedural modifications and suitable quality control, the required performance and operational life can be met with the VCD/UPA.

  15. Life Testing of the Vapor Compression Distillation Urine Processing Assembly (VCD/UPA) at the Marshall Space Flight Center

    NASA Technical Reports Server (NTRS)

    Wieland, Paul O.

    1998-01-01

    Wastewater and urine generated on the International Space Station will be processed to recover pure water. The method selected is vapor compression distillation (VCD). To verify the long-term reliability and performance of the VCD Urine Processing Assembly (UPA), accelerated life testing was performed at the Marshall Space Flight Center (MSFC) from January 1993 to April 1996. Two UPAS, the VCD-5 and VCD-5A, were tested for 204 days and 665 days, respectively. The compressor gears and the distillation centrifuge drive belt were found to have an operating life of approximately 4800 hours. Precise alignment of the flex-spline of the fluids pump is essential to avoid failure of the pump after about 400 hours of operation. Also, leakage around the seals of the drive shaft of the fluids pump and purge pump must be eliminated for continued good performance. Results indicate that, with some design and procedural modifications and suitable quality control, the required performance and operational life can be met with the VCD/UPA.

  16. Development of a new sensitive immunostrip assay based on mesoporous silica and colloidal Au nanoparticles.

    PubMed

    Omidfar, Kobra; Khorsand, Behnosh; Larijani, Bagher

    2012-02-01

    A new competitive immunostrip assay was developed to detect human serum albumin (HSA) in urine sample with use of conjugated monoclonal antibody gold nanoparticles (mAb-AuNPs) and mobile crystalline material (MCM)-41-HSA bioconjugate. To prepare the immunostrip, the colloidal AuNPs with an average particle diameter of 20 nm, was synthesized, labeled with antibody and applied on the conjugate pad as the detection reagent. Then, HSA was attached to the MCM-41 mesoporous nanoparticles and immobilized to a nitrocellulose membrane as the test line. In the optimized investigational conditions, the immunostrip could detect HSA in a high linear range (from 1 to 200 μg/ml) and low detection limit (ng/ml). The reliability of the testing procedure was examined by performing the immunostrip test with 30 urine samples and comparing the results with those obtained via immunoturbidimetry. The immunostrip was adequately sensitive and accurate for a rapid screening of HSA in the urine. This new strategy for competitive immunostrip design can be used and developed for other antigen based immunostrip assay.

  17. High-dose HOOK effect in urinary DcR2 assay in patients with chronic kidney disease.

    PubMed

    Chen, Jia; Chen, Ke-Hong; Wang, Li-Ming; Zhang, Wei-Wei; Feng, Lei; Dai, Huan-Zi; He, Ya-Ni

    2018-06-05

    Urinary DcR2 (uDcR2) is a biomarker for the early detection the tubulointerstitial injury (TII) in patients with chronic kidney disease (CKD), but the high-dose hook effect may lead to falsely low or even negative results when using an enzyme-linked immunosorbent assay (ELISA). This study aimed to investigate if the high-dose hook effect exists with ELISA testing, and to uncover a potential approach for reducing this effect. 72 CKD patients were recruited and categorized into four groups based on TII scores. uDcR2 was measured in undiluted and serially diluted (two-, four-, eight- and 16-fold dilutions) urine using an ELISA kit. The results from the assay were normalized to urinary creatinine. We evaluated the correlation between uDcR2/cre levels at different dilutions and renal histological parameters. Receiver operating characteristic (ROC) curves were generated to examine the value of uDcR2/cre for predicting TII. uDcR2/cre levels in the undiluted urine were significantly higher in patients with CKD than those in the control. However, higher TII scores did not yield higher levels of uDcR2/cre in the undiluted urine. After serial dilution, uDcR2/cre levels were highest with the four-fold dilution. A positive correlation was found between uDcR2/cre levels at different dilutions and TII scores, with the highest correlation coefficient and the largest AUC being observed at the four-fold dilution. The high-dose hook effect was apparent during ELISA testing of uDcR2 in CKD patients, yet dilution of the urine samples neutralized this effect. However, the use of a four-fold dilution of urine for uDcR2/cre testing may eliminate the high-dose hook effect and make it possible to effectively monitor the severity of TII in CKD patients. Copyright © 2018. Published by Elsevier Inc.

  18. Comparison between urine albumin-to-creatinine ratio and urine protein dipstick testing for prevalence and ability to predict the risk for chronic kidney disease in the general population (Iwate-KENCO study): a prospective community-based cohort study.

    PubMed

    Koeda, Yorihiko; Tanaka, Fumitaka; Segawa, Toshie; Ohta, Mutsuko; Ohsawa, Masaki; Tanno, Kozo; Makita, Shinji; Ishibashi, Yasuhiro; Itai, Kazuyoshi; Omama, Shin-Ichi; Onoda, Toshiyuki; Sakata, Kiyomi; Ogasawara, Kuniaki; Okayama, Akira; Nakamura, Motoyuki

    2016-05-12

    This study compared the combination of estimated glomerular filtration rate (eGFR) and urine albumin-to-creatinine ratio (UACR) vs. eGFR and urine protein reagent strip testing to determine chronic kidney disease (CKD) prevalence, and each method's ability to predict the risk for cardiovascular events in the general Japanese population. Baseline data including eGFR, UACR, and urine dipstick tests were obtained from the general population (n = 22 975). Dipstick test results (negative, trace, positive) were allocated to three levels of UACR (<30, 30-300, >300), respectively. In accordance with Kidney Disease Improving Global Outcomes CKD prognosis heat mapping, the cohort was classified into four risk grades (green: grade 1; yellow: grade 2; orange: grade 3, red: grade 4) based on baseline eGFR and UACR levels or dipstick tests. During the mean follow-up period of 5.6 years, 708 new onset cardiovascular events were recorded. For CKD identified by eGFR and dipstick testing (dipstick test ≥ trace and eGFR <60 mL/min/1.73 m(2)), the incidence of CKD was found to be 9 % in the general population. In comparison to non-CKD (grade 1), although cardiovascular risk was significantly higher in risk grades ≥3 (relative risk (RR) = 1.70; 95 % CI: 1.28-2.26), risk predictive ability was not significant in risk grade 2 (RR = 1.20; 95 % CI: 0.95-1.52). When CKD was defined by eGFR and UACR (UACR ≥30 mg/g Cr and eGFR <60 mL/min/1.73 m(2)), prevalence was found to be 29 %. Predictive ability in risk grade 2 (RR = 1.41; 95 % CI: 1.19-1.66) and risk grade ≥3 (RR = 1.76; 95 % CI: 1.37-2.28) were both significantly greater than for non-CKD. Reclassification analysis showed a significant improvement in risk predictive abilities when CKD risk grading was based on UACR rather than on dipstick testing in this population (p < 0.001). Although prevalence of CKD was higher when detected by UACR rather than urine dipstick testing, the predictive ability for cardiovascular events from UACR-based risk grading was superior to that of dipstick-based risk grading in the general population.

  19. Detection of bacteriuria and bacteremia in newborn calves by a catalase-based urine test.

    PubMed

    Raboisson, D; Clément, J; Queney, N; Lebreton, P; Schelcher, F

    2010-01-01

    Bacteremia occurs frequently in newborn calves. The predictive value of clinical signs is low, suggesting the use of calf-side diagnostic tests. To investigate testing of urine catalase activity (Uriscreen test) for bacteriuria and bacteremia detection. Five colostrum-free calves and 3 colostrum-fed control calves. Controlled experimental trial. Colostrum-free calves were inoculated PO with Escherichia coli O78+. A clinical score was established to define the onset of the illness. Blood and urine (cystocentesis) samplings and cultures, and Uriscreen tests, were performed 4-6 times from inoculation to death. Three control calves received the same management as 3 inoculated calves, but with colostrum and without inoculation. Bacteremia was demonstrated in all of the inoculated colostrum-free calves and in none of the control calves. The E. coli O78+ strain, E. coli, and Klebsiella spp. were recovered from 4/5, 5/5, and 2/5 inoculated colostrum-free calves, respectively. Urine cultures were negative for the 2 groups at the start of the experiment; 5/5 colostrum-deprived inoculated calves were positive for E. coli thereafter whereas 3/3 controls remained negative. Concordance of Uriscreen tests with bacteremia and bacteriuria was 0.86 and 0.88, respectively. Kappa value of agreement between Uriscreen and bacteremia and bacteriuria was 0.73 and 0.76, respectively. Sensitivity of Uriscreen for bacteremia and bacteriuria was 80.0 and 86.6%, respectively, and specificity was 92.8 and 88.8%, respectively. The results suggest that Uriscreen can be used for detection of bacteremia in neonatal calves in connection with a constant bacteriuria. Copyright © 2010 by the American College of Veterinary Internal Medicine.

  20. Mutagenic activity and metabolites in the urine of workers exposed to trinitrotoluene (TNT).

    PubMed Central

    Ahlborg, G; Einistö, P; Sorsa, M

    1988-01-01

    Urine samples taken after work and after a free weekend from 50 workers employed in various activities in a chemical plant manufacturing explosives were analysed. On the basis of hygienic surveys, the subjects were divided into three categories of exposure to trinitrotoluene (TNT). The urine analyses consisted of gas chromatographic identification of TNT and its two metabolites, 4-ADNT and 2-ADNT, and a determination of the mutagenic activity. Two frame shift detector strains of Salmonella typhimurium were used, TA 98 and TA 98 NR, the latter being deficient in endogenous nitroreductase activity. On the basis of previous results on TNT mutagenicity, no exogeneous metabolic system was used to test the urine concentrates. Both tester strains showed that the mean urinary mutagenic activity was higher in the after work samples than in post weekend samples from the same subjects, showing that bacterial nitroreductase activity was not significantly responsible for the mutagenicity, although the response was higher with strain TA 98 than with TA 98 NR. The interindividual variation in urine mutagenicity was high, however, and the difference between the two sampling times was statistically significant (p less than 0.05) only for the high exposed group (workers in trotyl foundry and sieve house). Correlation between urinary mutagenicity and concentration of TNT in urine was poor; correlation was significant only with the urinary concentration of 4-ADNT. The correlation between urinary TNT and both metabolites was good (p less than 0.001). These results suggest that analysis of 4-ADNT in urine would be a sufficient biological measure for controlling exposure to TNT. PMID:3378017

  1. Natural calcium isotopic composition of urine as a marker of bone mineral balance.

    PubMed

    Skulan, Joseph; Bullen, Thomas; Anbar, Ariel D; Puzas, J Edward; Shackelford, Linda; LeBlanc, Adrian; Smith, Scott M

    2007-06-01

    We investigated whether changes in the natural isotopic composition of calcium in human urine track changes in net bone mineral balance, as predicted by a model of calcium isotopic behavior in vertebrates. If so, isotopic analysis of natural urine or blood calcium could be used to monitor short-term changes in bone mineral balance that cannot be detected with other techniques. Calcium isotopic compositions are expressed as delta(44)Ca, or the difference in parts per thousand between the (44)Ca/(40)Ca of a sample and the (44)Ca/(40)Ca of a standard reference material. delta(44)Ca was measured in urine samples from 10 persons who participated in a study of the effectiveness of countermeasures to bone loss in spaceflight, in which 17 weeks of bed rest was used to induce bone loss. Study participants were assigned to 1 of 3 treatment groups: controls received no treatment, one treatment group received alendronate, and another group performed resistive exercise. Measurements were made on urine samples collected before, at 2 or 3 points during, and after bed rest. Urine delta(44)Ca values during bed rest were lower in controls than in individuals treated with alendronate (P <0.05, ANOVA) or exercise (P <0.05), and lower than the control group baseline (P <0.05, t-test). Results were consistent with the model and with biochemical and bone mineral density data. Results confirm the predicted relationship between bone mineral balance and calcium isotopes, suggesting that calcium isotopic analysis of urine might be refined into a clinical and research tool.

  2. Blood in the Urine (Hematuria) (For Parents)

    MedlinePlus

    ... weeks later, just to make sure the urine is free of red blood cells. Hematuria that only happens once won't ... up tests to make sure your child's urine is free of red blood cells. Reviewed by: Robert S. Mathias, MD Date reviewed: ...

  3. Performance of polymerase chain reaction for the diagnosis of cystic echinococcosis using serum, urine, and cyst fluid samples

    PubMed Central

    Chaya, DR; Parija, Subhash Chandra

    2014-01-01

    Introduction: Cystic echinococcosis (CE) is a chronic zoonosis which presents with variable clinical manifestations. Currently the diagnosis of this disease is based on radiological findings and serological tests which lack specificity. Although antigen detection from the cyst fluid is the most specific, it is seldom done due to the complications involved. Detecting the presence of Echinococcus granulosus specific deoxyribonucleic acid (DNA) by the polymerase chain reaction (PCR) could provide a definitive diagnosis of CE. Materials and Methods: An in-house PCR assay was devised to detect E. granulosus specific DNA in serum, urine and hydatid cyst fluid. The ability of the PCR to detect E. granulosus in the above mentioned samples were observed in comparison with other antigen and antibody detection tests. Results: Serum samples from surgically confirmed patients of CE with ruptured cysts contained the corresponding DNA while the in the majority of cases who had an intact cyst had no DNA of E. granulosus in their serum. DNA of E. granulosus was not found to be excreted in urine. PCR performed equal to antigen detection ELISA while testing hydatid cyst fluid samples. Conclusions: Serum and urine might not serve as useful samples for the molecular diagnosis of cystic echinococcosis. However, PCR can be useful on serum samples to detect ruptured hydatid cysts and on hydatid cyst fluid to confirm the parasitic diagnosis. PMID:24754027

  4. Water recovery by catalytic treatment of urine vapor

    NASA Technical Reports Server (NTRS)

    Budininkas, P.; Quattrone, P. D.; Leban, M. I.

    1980-01-01

    The objective of this investigation was to demonstrate the feasibility of water recovery on a man-rated scale by the catalytic processing of untreated urine vapor. For this purpose, two catalytic systems, one capable of processing an air stream containing low urine vapor concentrations and another to process streams with high urine vapor concentrations, were designed, constructed, and tested to establish the quality of the recovered water.

  5. Biochemical, molecular, and clinical diagnoses of patients with cerebral creatine deficiency syndromes.

    PubMed

    Comeaux, Matthew S; Wang, Jing; Wang, Guoli; Kleppe, Soledad; Zhang, Victor Wei; Schmitt, Eric S; Craigen, William J; Renaud, Deborah; Sun, Qin; Wong, Lee-Jun

    2013-07-01

    Cerebral creatine deficiency syndromes (CCDS) are a group of inborn errors of creatine metabolism that involve AGAT and GAMT for creatine biosynthesis disorders and SLC6A8 for creatine transporter (CT1) deficiency. Deficiencies in the three enzymes can be distinguished by intermediate metabolite levels, and a definitive diagnosis relies on the presence of deleterious mutations in the causative genes. Mutations and unclassified variants were identified in 41 unrelated patients, and 22 of these mutations were novel. Correlation of sequencing and biochemical data reveals that using plasma guanidinoacetate (GAA) as a biomarker has 100% specificity for both AGAT and GAMT deficiencies, but AGAT deficiency has decreased sensitivity in this assay. Furthermore, the urine creatine:creatinine ratio is an effective screening test with 100% specificity in males suspected of having creatine transporter deficiency. This test has a high false-positive rate due to dietary factors or dilute urine samples and lacks sensitivity in females. We conclude that biochemical screening for plasma GAA and measuring of the urine creatine:creatinine ratio should be performed for suspected CCDS patients prior to sequencing. Also, based on the results of this study, we feel that sequencing should only be considered if a patient has abnormal biochemical results on repeat testing. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. Study on a novel core module based on optical fiber bundles for urine dry-chemistry analysis

    NASA Astrophysics Data System (ADS)

    Liu, Gaiqin; Ma, Zengwei; Li, Rui; Hu, Nan; Chen, Ping; Wang, Fei; Zhang, Ruiying; Chen, Longcong

    2017-09-01

    A core module with a novel optical structure is presented to analyze urine by the dry-chemistry method in this paper. It consists of a 32-bit microprocessor, optical fiber bundles, a high precision color sensor and a temperature sensor. The optical fiber bundles are adopted to control the spread path of light and reduce the influence of ambient light and the distance between the strip and sensor effectively. And the temperature sensor is applied to detect the environmental temperature to calibrate the measurement results. Therefore, all these can bring a lot of benefits to the core module, such as improving its test accuracy, reducing its volume and cost, and simplifying its assembly. Additionally, some parameters, including the calculation coefficient about reflectivity of each item, semi-quantitative intervals, the number of test items, may be modified by corresponding instructions in order to enhance its applicability. Meanwhile, its outputs can be chosen among the original data, normalized color values, reflectivity, and the semi-quantitative level of each test item by available instructions. Our results show that the module has high measurement accuracy of more than 95%, good stability, reliability, and consistency and can be easily used in various types of urine analyzers.

  7. Cadmium exposure and neuropsychological development in school children in southwestern Spain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rodríguez-Barranco, Miguel; Instituto de Investigación Biosanitaria de Granada; Lacasaña, Marina, E-mail: marina.lacasana.easp@juntadeandalucia.es

    This study assessed the association between cadmium exposure and neuropsychological development in children from a region with high industrial and mining activities in southwestern Spain. We conducted a cross-sectional study with 261 children aged 6–9 years between January and March 2012. Cadmium exposure was measured in urine and hair of children, and neuropsychological development was assessed with the Wechsler Intelligence Scale for Children-Fourth Edition (WISC-IV) and with three computerized tests from the Behavioral Assessment and Research System (BARS): Reaction Time Test (RTT), Continuous Performance Test (CPT) and Selective Attention Test (SAT). Multivariate linear regression models, adjusted for potential confounders, weremore » used to estimate the association between neuropsychological development and cadmium exposure measured in urine and hair samples. Geometric means of urine and hair cadmium levels were 0.75 μg/g creatinine and 0.01 μg/g, respectively. We observed that doubling of levels of cadmium in urine was associated with a reduction of two points (95% CI: −3.8 to −0.4) in the Full-Scale intelligence quotient (IQ) in boys. By domains, association was statistically significant for Verbal Comprehension (β=−2.0; p=0.04) and close to the significance level for Perceptual Reasoning (β=−1.8; p=0.06). Among girls, only Verbal Comprehension showed suggestive associations with cadmium exposure (β=−1.7; p=0.06). Cadmium exposure is associated with cognitive delays in boys in our region. Our results provide additional evidence of the neurotoxic effect of low-level postnatal cadmium exposure among children, and support the hypothesis of differences between sexes in the neurotoxic effect of metals on children. - Highlights: • This study associates Cd exposure and neuropsychological development in children. • Cd exposure was associated with cognitive delay in boys, but not in girls. • Intellectual quotient of boys decreased two points for a doubling of urine Cd levels. • Verbal Comprehension and Perceptual Reasoning were the most affected domains in boys. • Results support the sex-related differences in the neurotoxicity of metals in children.« less

  8. Utility of ELISA screening for the monitoring of abstinence from illegal and legal drugs in hair and urine.

    PubMed

    Agius, Ronald; Nadulski, Thomas

    2014-06-01

    Amphetamines, cannabinoids, cocaine, opiates, methadone, and benzodiazepines in authentic hair samples with drug concentrations around the medical and psychological assessment (MPA) guidelines cut-offs were screened by LUCIO-direct ELISA kits. Following confirmation of all positive and a significant number of negatively screened samples with gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods accredited for forensic purposes. Receiver operating characteristics (ROC) were plotted and the area under the curve (AUC) and overall misclassification rate (OMR) were calculated and compared to those obtained for the same drug classes in urine. While fulfilling the validation criteria of the German forensic guidelines, for almost all screening tests in hair and urine the AUC were greater than 0.8, indicating good to excellent performance. Moreover the AUC calculated for the detection of drugs in hair did not differ significantly to the AUC calculated for the detection of the same drug classes in urine, thus showing a comparable screening performance to the well accepted, previously published application of the same ELISAs for the detection of drugs at unconventionally low cut-offs in urine. For the first time, the validation of the immunoassay tests for the complete 6-drug panel MPA profile in hair and urine using a large population of authentic hair and urine samples with drug concentrations around MPA cut-offs, lower than conventional clinical or workplace drug testing guidelines cut-offs as well as those suggested by the Society of hair testing (SoHT) is presented. Copyright © 2014 John Wiley & Sons, Ltd.

  9. Epidemiological investigation of the UGT2B17 polymorphism in doping control urine samples and its correlation to T/E ratios.

    PubMed

    Anielski, Patricia; Simmchen, Juliane; Wassill, Lars; Ganghofner, Dirk; Thieme, Detlef

    2011-10-01

    The deletion polymorphism of the enzyme UGT2B17 is known to correlate with the level of the testosterone to epitestosterone (T/E) ratio in urine specimen. Due to the importance of the T/E ratio to detect testosterone abuse in doping analysis, a PCR-ELISA system (Genotype® UGT test, AmplexDiagnostics) was established to identify the UGT2B17 phenotype in urine samples. Epidemiological investigations in a set of 674 routine doping controls (in- and out-of-competition) resulted in 22.8% homozygote gene-deleted and 74.5% UGT2B17-positive athletes. The validated test system has shown to be robust and sensitive: in only 18 cases (2.7%) isolation of cell material from urine failed. Following hydrolysis of glucuronidated conjugates, steroids were analyzed as bis-TMS derivatives by gas chromatography-mass spectrometry (GC-MS), for example, testosterone (T) and epitestosterone (E). Additionally, isotope ration mass spectrometry (IRMS) analysis and luteinizing hormone (LH) measurement were applied. Mean T/E ratios significantly correlated with the UGT2B17 phenotype (del: T/E 0.9; pos: 1.7), however the values did not differ as distinctive as reported in previous studies. Additionally, the T/E ratios in the gene-deleted group did not show a normal curve of distribution (median of T/E 0.5). Obviously, beside the UGT2B17 deletion further influences have to be taken into account, for example, polymorphisms or induction of other metabolizing enzymes. Our results indicate that the UGT2B17 polymorphism might be insufficient when utilized solely as a crucial parameter for individual interpretation of T/E in urine. Nevertheless, the detection of the UGT2B17-gene deletion in urine samples would provide additional information important for gathering evidence in analysis of steroids in doping control. Copyright © 2011 John Wiley & Sons, Ltd.

  10. Detection of novel visible-light region absorbance peaks in the urine after alkalization in patients with alkaptonuria.

    PubMed

    Tokuhara, Yasunori; Shukuya, Kenichi; Tanaka, Masami; Mouri, Mariko; Ohkawa, Ryunosuke; Fujishiro, Midori; Takahashi, Tomoo; Okubo, Shigeo; Yokota, Hiromitsu; Kurano, Makoto; Ikeda, Hitoshi; Yamaguchi, Seiji; Inagaki, Shinobu; Ishige-Wada, Mika; Usui, Hiromi; Yatomi, Yutaka; Shimosawa, Tatsuo

    2014-01-01

    Alkaptonuria, caused by a deficiency of homogentisate 1,2-dioxygenase, results in the accumulation of homogentisic acid (2,5-dihydroxyphenylacetic acid, HGA) in the urine. Alkaptonuria is suspected when the urine changes color after it is left to stand at room temperature for several hours to days; oxidation of homogentisic acid to benzoquinone acetic acid underlies this color change, which is accelerated by the addition of alkali. In an attempt to develop a facile screening test for alkaptonuria, we added alkali to urine samples obtained from patients with alkaptonuria and measured the absorbance spectra in the visible light region. We evaluated the characteristics of the absorption spectra of urine samples obtained from patients with alkaptonuria (n = 2) and compared them with those of urine specimens obtained from healthy volunteers (n = 5) and patients with phenylketonuria (n = 3), and also of synthetic homogentisic acid solution after alkalization. Alkalization of the urine samples and HGA solution was carried out by the addition of NaOH, KOH or NH4OH. The sample solutions were incubated at room temperature for 1 min, followed by measurement of the absorption spectra. Addition of alkali to alkaptonuric urine yielded characteristic absorption peaks at 406 nm and 430 nm; an identical result was obtained from HGA solution after alkalization. The absorbance values at both 406 nm and 430 nm increased in a time-dependent manner. In addition, the absorbance values at these peaks were greater in strongly alkaline samples (NaOH- KOH-added) as compared with those in weakly alkaline samples (NH4OH-added). In addition, the peaks disappeared following the addition of ascorbic acid to the samples. We found two characteristic peaks at 406 nm and 430 nm in both alkaptonuric urine and HGA solution after alkalization. This new quick and easy method may pave the way for the development of an easy method for the diagnosis of alkaptonuria.

  11. The Effects of Instrumentation on Urine Cytology and CK-20 Analysis for the Detection of Bladder Cancer.

    PubMed

    Wegelin, Olivier; Bartels, Diny W M; Tromp, Ellen; Kuypers, Karel C; van Melick, Harm H E

    2015-10-01

    To evaluate the effects of cystoscopy on urine cytology and additional cytokeratin-20 (CK-20) staining in patients presenting with gross hematuria. For 83 patients presenting with gross hematuria, spontaneous and instrumented paired urine samples were analyzed. Three patients were excluded. Spontaneous samples were collected within 1 hour before cystoscopy, and the instrumented samples were tapped through the cystoscope. Subsequently, patients underwent cystoscopic evaluation and imaging of the urinary tract. If tumor suspicious lesions were found on cystoscopy or imaging, subjects underwent transurethral resection or ureterorenoscopy. Two blinded uropathological reviewers (DB, KK) evaluated 160 urine samples. Reference standards were results of cystoscopy, imaging, or histopathology. Thirty-seven patients (46.3%) underwent transurethral resection or ureterorenoscopy procedures. In 30 patients (37.5%) tumor presence was confirmed by histopathology. The specificity of urine analysis was significantly higher for spontaneous samples than instrumented samples for both cytology alone (94% vs 72%, P = .01) and for cytology combined with CK-20 analysis (98% vs 84%, P = .02). The difference in sensitivity between spontaneous and instrumented samples was not significant for both cytology alone (40% vs 53%) and combined with CK-20 analysis (67% vs 67%). The addition of CK-20 analysis to cytology significantly increases test sensitivity in spontaneous urine cytology (67% vs 40%, P = .03). Instrumentation significantly decreases specificity of urine cytology. This may lead to unnecessary diagnostic procedures. Additional CK-20 staining in spontaneous urine cytology significantly increases sensitivity but did not improve the already high specificity. We suggest performing urine cytology and CK-20 analysis on spontaneously voided urine. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. An investigation of the stability of free and glucuronidated 11-nor-delta9-tetrahydrocannabinol-9-carboxylic acid in authentic urine samples.

    PubMed

    Skopp, Gisela; Pötsch, Lucia

    2004-01-01

    Preanalytical stability of a drug and its major metabolites is an important consideration in pharmacokinetic studies or whenever the analyte pattern is used to estimate drug habits. Firstly, the stability of free and glucuronidated 11-nor-delta9-tetrahydrocannabinol-9-carboxylic acid (THCCOOH, THCCOOglu) in authentic urine samples was investigated. Random urine samples of cannabis users (n = 38) were stored at -20, 4, and 20 degrees C up to 15 days and up to 5 days at 40 degrees C, and alterations of the analyte pattern during storage were followed by liquid chromatography-tandem mass spectrometry. Secondly, the influence of pH (range 5.0-8.0) on the stability of the analytes was studied using spiked urine to elucidate the results obtained from authentic samples. In authentic urine samples, the initial pH ranged from 5.1 to 8.8. The glucuronide was found to be highly labile at a storage temperature of 4 degrees C and above. Initially, 18 urine samples tested positive for THCCOOH. After 2 days storage at 20 degrees C, THCCOOH was detectable in a further 4 samples, and 7 more samples tested positive for THCCOOH (5-81 ng/mL) after 15 days. Depending on time and temperature, the glucuronide concentration decreased, resulting in an increase of THCCOOH concentration. However, a loss in mean total THCCOOH concentration was found, which was significantly higher in deteriorated samples than in samples without signs of deterioration after 15 days of storage at 20 degrees C. In the drug-free urine sample separately spiked with THCCOOglu or THCCOOH, the investigations on the stability of the target analytes at various pH values revealed that THCCOOH was stable at pH 5.0. At higher pH values, its concentration slightly decreased with time, and about 69% of the initial THCCOOH concentration was still present at pH 8.0 on day 5. THCCOOglu concentrations rapidly decreased with increasing pH value. For example, only 72% of the initial THCCOOglu concentration could be detected at pH 5.0 on day 1. Degradation of the glucuronide resulted in formation of THCCOOH, which was observed even at pH 5.0. In light of the present findings, advanced forensic interpretations based on the presence of THCCOOH or the pattern of THCCOOH and THCCOOglu in stored urine samples seems questionable.

  13. Water Prescription in Autosomal Dominant Polycystic Kidney Disease: A Pilot Study

    PubMed Central

    Creed, Catherine; Winklhofer, Franz T.; Grantham, Jared J.

    2011-01-01

    Summary Background and objectives In animal models of polycystic kidney disease, the ingestion of large amounts of water promotes diuresis by suppressing plasma levels of arginine vasopressin (AVP) and renal levels of cAMP, slowing cyst progression. Whether simple water ingestion is a potential therapeutic strategy for individuals with autosomal dominant polycystic kidney disease (ADPKD) is unknown. In this study, a simple method to quantify the amount of water to achieve a specific mean urine osmolality target in patients with ADPKD was developed and tested. Design, setting, participants, & measurements In eight ADPKD patients eating typical diets, osmolality and volume were measured in 24-hour urine collections. The amount of additional ingested water required daily to achieve a mean urine osmolality of 285 ± 45 mosm/kg was determined. Participants were instructed to distribute the prescribed water over waking hours for each of 5 days. Blood chemistries, 24-hour urine collections, BP, and weight were measured before and after the period of supplemental water intake. Results Five patients achieved the 285 mosm/kg urine target without difficulty. Mean urine osmolality decreased and mean urine volume increased; serum sodium, weight, and BP were unchanged. Daily osmolar excretion remained constant, indicating a stable ad lib dietary intake of solutes and protein over the 2-week study period. Conclusions The amount of additional water needed to achieve a urine osmolality target can be approximated from the urine osmolar excretion in ADPKD patients eating typical diets, providing a quantitative method to prescribe supplemental water for such individuals. PMID:20876670

  14. 21 CFR 862.1550 - Urinary pH (nonquantitative) test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... (nonquantitative) test system is a device intended to estimate the pH of urine. Estimations of pH are used to evaluate the acidity or alkalinity of urine as it relates to numerous renal and metabolic disorders and in...

  15. 21 CFR 862.1550 - Urinary pH (nonquantitative) test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... (nonquantitative) test system is a device intended to estimate the pH of urine. Estimations of pH are used to evaluate the acidity or alkalinity of urine as it relates to numerous renal and metabolic disorders and in...

  16. Contemporary Attitudes and Practice Patterns of North American Urologists in Investigating Stone-Forming Patients-A Survey of Endourological Society Members.

    PubMed

    McGuire, Barry B; Matulewicz, Richard S; Zuccarino-Crowe, Rian; Nadler, Robert B; Perry, Kent T

    2016-04-01

    Recent evidence would suggest a low rate of metabolic assessment in stone formers, even in those deemed as high risk. We wished to assess the attitudes and practice patterns of metabolic work up in North American members of the Endourological Society as part of the management of stone-forming patients. A 12-question online multiple-choice questionnaire (using Survey Monkey(®)) was distributed to all members of the Endourological Society through e-mail. Descriptive analyses were performed. A total of 124 North American members of the Endourological Society responded (90% endourologists, 65% fellowship trained). Ninety-seven percent perform metabolic assessments without referring to a consultant. Eighty-three percent use a commercial analysis company and 17% request serum or urine parameters individually. Ninety-seven percent believe that 24-48-hour urine collection is a better way of assessing patients for metabolic abnormalities than a "basic analysis." Many respondents (37%) would be more likely to metabolically assess if results were easier to interpret, and 35% would like assistance/advice in the interpretation of results. At initial investigation of a first-time stone former, 87% of respondents use serum chemistry, 48% use 24-hour urine, 26% use 48-hour urine (two consecutive 24-hour urine collections), 54% send stone for analysis, and 7% do not investigate. On recurrent stone formers, 69% use serum chemistry, 73% use 24/48-hour urine, and 23% send stone for analysis. On routine follow-up, 36% check serum chemistry, 55% use 24-hour urine, 2% use 48-hour urine, and 29% do not metabolically evaluate. The majority agree that pharmacologic therapy plays a strong role in preventing recurrence (90%). After initiating pharmacologic therapy, 59% reassess using serum chemistry and 84% and 7% use 24/48-hour urine collection, respectively. Physicians re-evaluate patients after 1 month (7%), 1-2 months (10%), 2-4 months (44%), 4-6 months (30%), or after 6-12 months (7%). This snapshot assessment of Endourological Society members' practices in the metabolic investigation of stone-forming patients demonstrates wide testing variations. Many physicians expressed interest in assistance/advice in the interpretation of the metabolic assessment results.

  17. 49 CFR 40.45 - What form is used to document a DOT urine collection?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Collection Sites, Forms, Equipment and Supplies Used... Federal Drug Testing Custody and Control Form (CCF) must be used to document every urine collection required by the DOT drug testing program. The CCF must be a five-part carbonless manifold form. You may...

  18. 49 CFR 40.45 - What form is used to document a DOT urine collection?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Collection Sites, Forms, Equipment and Supplies Used... Federal Drug Testing Custody and Control Form (CCF) must be used to document every urine collection required by the DOT drug testing program. The CCF must be a five-part carbonless manifold form. You may...

  19. 49 CFR 40.45 - What form is used to document a DOT urine collection?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Collection Sites, Forms, Equipment and Supplies Used... Federal Drug Testing Custody and Control Form (CCF) must be used to document every urine collection required by the DOT drug testing program. The CCF must be a five-part carbonless manifold form. You may...

  20. Influence of the urine flow rate on some caffeine metabolite ratios used to assess CYP1A2 activity.

    PubMed

    Sinués, Blanca; Fanlo, Ana; Bernal, María Luisa; Mayayo, Esteban; Soriano, María Antonia; Martínez-Ballarin, Enrique

    2002-12-01

    Five established metabolite ratios (MRs) to measure P450 CYP1A2 activity--MR1 (17X + 17U)/137X, MR2 (AFMU + 1X + 1U)/17U, MR3 (17X/137X), MR4 (AFMU + 1X + 1U + 17X + 17U)/137X, and MR5 (AFMU + 1X + 1U)/17X--were calculated in urine 4-5 hours after caffeine intake. First, to assess the potential of omeprazole to induce CYP1A2 activity, a caffeine test was performed in 27 subjects on two occasions: before and after 14 days on omeprazole (20 mg/day). Samples of urine were analyzed by high-performance liquid chromatography (HPLC) to quantify caffeine and metabolites used to calculate the different caffeine MRs. MR1, MR3, and MR4 were enhanced after treatment; the percentage of change was inversely associated with that of the urine flow, with r values of -0.48, -0.49, and -0.47, respectively. However, MR2 or MR5 were not modified. To determine the reason for these contradictory results, the authors analyzed data of metabolites, ratios, and their components (numerators and denominators) from 152 subjects (who underwent one caffeine test) and their relationship with the urinary flow. Caffeine concentration in urine was the only compound nondependent on the urine flow. Consistently, ratios containing caffeine (MR1, MR3, and MR4) were highly influenced by the rate of urine excretion, since the flow dependence of their numerators is not canceled out by that of caffeine in their denominators. The dependency of the caffeine excretion on renal factors may explain the opposite results found with the different ratios in the aforementioned prospective study of drug interaction, the absence of closer correlations of the five MRs to each other, the discrepancies about the type of frequency distribution of the different MRs (either normal or multimodal), and the higher sensitivity of MR2 to detect gender differences in CYP1A2 activity found in this study. In summary, the data clearly emphasize the need for a strict control of the liquid intake to avoid high urine flows when MRs containing caffeine are used to assess CYP1A2 activity, especially in studies of drug interactions.

Top