Kramer, Harald; Pickhardt, Perry J; Kliewer, Mark A; Hernando, Diego; Chen, Guang-Hong; Zagzebski, James A; Reeder, Scott B
2017-01-01
The purpose of this study was to prospectively evaluate the accuracy of proton-density fat-fraction, single- and dual-energy CT (SECT and DECT), gray-scale ultrasound (US), and US shear-wave elastography (US-SWE) in the quantification of hepatic steatosis with MR spectroscopy (MRS) as the reference standard. Fifty adults who did not have symptoms (23 men, 27 women; mean age, 57 ± 5 years; body mass index, 27 ± 5) underwent liver imaging with un-enhanced SECT, DECT, gray-scale US, US-SWE, proton-density fat-fraction MRI, and MRS for this prospective trial. MRS voxels for the reference standard were colocalized with all other modalities under investigation. For SECT (120 kVp), attenuation values were recorded. For rapid-switching DECT (80/140 kVp), monochromatic images (70-140 keV) and fat density-derived material decomposition images were reconstructed. For proton-density fat fraction MRI, a quantitative chemical shift-encoded method was used. For US, echogenicity was evaluated on a qualitative 0-3 scale. Quantitative US shear-wave velocities were also recorded. Data were analyzed by linear regression for each technique compared with MRS. There was excellent correlation between MRS and both proton-density fat-fraction MRI (r 2 = 0.992; slope, 0.974; intercept, -0.943) and SECT (r 2 = 0.856; slope, -0.559; intercept, 35.418). DECT fat attenuation had moderate correlation with MRS measurements (r 2 = 0.423; slope, 0.034; intercept, 8.459). There was good correlation between qualitative US echogenicity and MRS measurements with a weighted kappa value of 0.82. US-SWE velocity did not have reliable correlation with MRS measurements (r 2 = 0.004; slope, 0.069; intercept, 6.168). Quantitative MRI proton-density fat fraction and SECT fat attenuation have excellent linear correlation with MRS measurements and can serve as accurate noninvasive biomarkers for quantifying steatosis. Material decomposition with DECT does not improve the accuracy of fat quantification over conventional SECT attenuation. US-SWE has poor accuracy for liver fat quantification.
2012-01-01
Background In 2006, we were funded by the US National Institutes of Health to implement a study of tuberculosis epidemiology in Peru. The study required a secure information system to manage data from a target goal of 16,000 subjects who needed to be followed for at least one year. With previous experience in the development and deployment of web-based medical record systems for TB treatment in Peru, we chose to use the OpenMRS open source electronic medical record system platform to develop the study information system. Supported by a core technical and management team and a large and growing worldwide community, OpenMRS is now being used in more than 40 developing countries. We adapted the OpenMRS platform to better support foreign languages. We added a new module to support double data entry, linkage to an existing laboratory information system, automatic upload of GPS data from handheld devices, and better security and auditing of data changes. We added new reports for study managers, and developed data extraction tools for research staff and statisticians. Further adaptation to handle direct entry of laboratory data occurred after the study was launched. Results Data collection in the OpenMRS system began in September 2009. By August 2011 a total of 9,256 participants had been enrolled, 102,274 forms and 13,829 laboratory results had been entered, and there were 208 users. The system is now entirely supported by the Peruvian study staff and programmers. Conclusions The information system served the study objectives well despite requiring some significant adaptations mid-stream. OpenMRS has more tools and capabilities than it did in 2008, and requires less adaptations for future projects. OpenMRS can be an effective research data system in resource poor environments, especially for organizations using or considering it for clinical care as well as research. PMID:23131180
2. WEST FRONT ENTRANCE, WITH OWNERS MR. & MRS. ISACC ...
2. WEST FRONT ENTRANCE, WITH OWNERS MR. & MRS. ISACC N. HAGAN (WHO CONTRACTED WITH FRANK LLOYD WRIGHT FOR THE DESIGN OF THIS HOUSE) - Isaac N. Hagan House, Kentuck Knob, U.S. Route 40 vicinity (Stewart Township), Chalkhill, Fayette County, PA
Human factors for capacity building: lessons learned from the OpenMRS implementers network.
Seebregts, C J; Mamlin, B W; Biondich, P G; Fraser, H S F; Wolfe, B A; Jazayeri, D; Miranda, J; Blaya, J; Sinha, C; Bailey, C T; Kanter, A S
2010-01-01
The overall objective of this project was to investigate ways to strengthen the OpenMRS community by (i) developing capacity and implementing a network focusing specifically on the needs of OpenMRS implementers, (ii) strengthening community-driven aspects of OpenMRS and providing a dedicated forum for implementation-specific issues, and; (iii) providing regional support for OpenMRS implementations as well as mentorship and training. The methods used included (i) face-to-face networking using meetings and workshops; (ii) online collaboration tools, peer support and mentorship programmes; (iii) capacity and community development programmes, and; (iv) community outreach programmes. The community-driven approach, combined with a few simple interventions, has been a key factor in the growth and success of the OpenMRS Implementers Network. It has contributed to implementations in at least twenty-three different countries using basic online tools; and provided mentorship and peer support through an annual meeting, workshops and an internship program. The OpenMRS Implementers Network has formed collaborations with several other open source networks and is evolving regional OpenMRS Centres of Excellence to provide localized support for OpenMRS development and implementation. These initiatives are increasing the range of functionality and sustainability of open source software in the health domain, resulting in improved adoption and enterprise-readiness. Social organization and capacity development activities are important in growing a successful community-driven open source software model.
Information Technology: A Tool to Cut Health Care Costs
NASA Technical Reports Server (NTRS)
Mukkamala, Ravi; Maly, K. J.; Overstreet, C. M.; Foudriat, E. C.
1996-01-01
Old Dominion University embarked on a project to see how current computer technology could be applied to reduce the cost and or to improve the efficiency of health care services. We designed and built a prototype for an integrated medical record system (MRS). The MRS is written in Tool control language/Tool kit (Tcl/Tk). While the initial version of the prototype had patient information hard coded into the system, later versions used an INGRES database for storing patient information. Currently, we have proposed an object-oriented model for implementing MRS. These projects involve developing information systems for physicians and medical researchers to enhance their ability for improved treatment at reduced costs. The move to computerized patient records is well underway, several standards exist for laboratory records, and several groups are working on standards for other portions of the patient record.
Video: Mrs. Bush Introduces Preserve America
; the U.S. Departments of Defense, Interior, Agriculture, Commerce, Housing and Urban Development . Department of Commerce seal U.S. Department of Agriculture logo U.S. Department of Housing and Urban
Mrs. Laura Bush Announces First Preserve America Grant Recipients,
Preservation; the U.S. Departments of Defense, Interior, Agriculture, Commerce, Housing and Urban Development . Department of Commerce seal U.S. Department of Agriculture logo U.S. Department of Housing and Urban
NASA Astrophysics Data System (ADS)
Anstey, Josephine; Pape, Dave
2013-03-01
In this paper we discuss Mrs. Squandertime, a real-time, persistent simulation of a virtual character, her living room, and the view from her window, designed to be a wall-size, projected art installation. Through her large picture window, the eponymous Mrs. Squandertime watches the sea: boats, clouds, gulls, the tide going in and out, people on the sea wall. The hundreds of images that compose the view are drawn from historical printed sources. The program that assembles and animates these images is driven by weather, time, and tide data constantly updated from a real physical location. The character herself is rendered photographically in a series of slowly dissolving stills which correspond to the character's current behavior.
Is muscle energy production disturbed in exertional heat stroke?
Sagui, Emmanuel; Abriat, Amandine; Kozak-Ribbens, Geneviève; Foutrier-Morello, Catherine; Bernard, Monique; Canini, Frédéric; Brosset, Christian; Bendahan, David
2014-03-01
Exertional heat stroke (EHS) is a life-threatening disease that shares some clinical similarities with malignant hyperthermia (MH). By use of (31)Phosphorus magnetic resonance spectroscopy (MRS), EHS patients with MH susceptibility and MH patients shared common metabolic abnormalities. The aim of this study was to determine whether subjects who suffered from an EHS episode had disturbed muscle energetics. This retrospective study was performed within the French database of military subjects that were explored from 2004 to 2010 after they suffered an EHS. All subjects had both in vitro contracture test to determine their MH susceptibility and (31)Phosphorus MRS at 4.7 Tesla to assess muscle energetics by means of MRS score, a composite score corresponding to the sum of metabolic abnormalities recorded during a standardized rest-exercise-recovery protocol. 437 subjects were investigated and 32.5% of them exhibited abnormal MRS score. MRS score did not segregate subjects on demographic, clinical, or biological grounds. No clear correlation could be done between MH status and MRS score. These results did not confirm the potential relationship between calcium homeostasis and muscle energetics previously reported. However, muscle energy production was disturbed in a significant number of EHS subjects. Reprint & Copyright © 2014 Association of Military Surgeons of the U.S.
Toussaint, Magali; Pinel, Sophie; Auger, Florent; Durieux, Nicolas; Thomassin, Magalie; Thomas, Eloise; Moussaron, Albert; Meng, Dominique; Plénat, François; Amouroux, Marine; Bastogne, Thierry; Frochot, Céline; Tillement, Olivier; Lux, François; Barberi-Heyob, Muriel
2017-01-01
Despite recent progress in conventional therapeutic approaches, the vast majority of glioblastoma recur locally, indicating that a more aggressive local therapy is required. Interstitial photodynamic therapy (iPDT) appears as a very promising and complementary approach to conventional therapies. However, an optimal fractionation scheme for iPDT remains the indispensable requirement. To achieve that major goal, we suggested following iPDT tumor response by a non-invasive imaging monitoring. Nude rats bearing intracranial glioblastoma U87MG xenografts were treated by iPDT, just after intravenous injection of AGuIX® nanoparticles, encapsulating PDT and imaging agents. Magnetic Resonance Imaging (MRI) and Magnetic Resonance Spectroscopy (MRS) allowed us an original longitudinal follow-up of post-treatment effects to discriminate early predictive markers. We successfully used conventional MRI, T2 star (T2*), Diffusion Weighted Imaging (DWI) and MRS to extract relevant profiles on tissue cytoarchitectural alterations, local vascular disruption and metabolic information on brain tumor biology, achieving earlier assessment of tumor response. From one day post-iPDT, DWI and MRS allowed us to identify promising markers such as the Apparent Diffusion Coefficient (ADC) values, lipids, choline and myoInositol levels that led us to distinguish iPDT responders from non-responders. All these responses give us warning signs well before the tumor escapes and that the growth would be appreciated.
Apollo 12 crewmembers greeted by family on arrival at Ellington
NASA Technical Reports Server (NTRS)
1969-01-01
Members of the Apollo 12 lunar landing mission's crew are greeted by their wives and children at the front of a large crowd on hand to welcome home the three. The Mobile Quarantine Facility (MQF), with the crew inside, arrived at Ellington Air Force Base aboard a U.S. Air Force C0141 transport jet on November 29, 1969. The crewmen, looking out the MQF window at the crowd, are (l-r) Astronauts Charles Conrad Jr., Richard F. Gordon Jr., and ALan L. Bean. Their wives are, from left to right, Mrs. Barbara Gordon, Mrs Jane Conrad and Mrs. Sue Bean. The women are wearing leis, an Hawaii tradition (60759); Conrad talks by phone to members of his family standing outside the MQF. Beside him are Gordon (center) and Bean (60760).
Mobile Quarantine Facility (MQF) - Ellington AFB (EAFB), TX
1969-07-27
S69-40147 (27 July 1969) --- The Apollo 11 crewmen, still under a 21-day quarantine, are greeted by their wives. They arrived at Ellington Air Force Base very early Sunday after a flight aboard a U.S. Air Force C-141 transport from Hawaii. Looking through the window of a Mobile Quarantine Facility (MQF) are (left to right) astronauts Neil A. Armstrong, Edwin E. Aldrin Jr., and Michael Collins. The wives are (left to right) Mrs. Pat Collins, Mrs. Jan Armstrong, and Mrs. Joan Aldrin. The crew of the historic Apollo 11 lunar landing mission remained in the MQF until they arrived to the Crew Reception Area of the Lunar Receiving Laboratory at the Manned Spacecraft Center (MSC). The astronauts will be released from quarantine on Aug. 11, 1969.
Physical association and periodicity in quasar families with SDSS and 2MRS
NASA Astrophysics Data System (ADS)
Fulton, C. C.; Arp, H. C.; Hartnett, J. G.
2018-07-01
We have used the Sloan Digital Sky Survey (SDSS) data release 7 (DR7) and the 2MASS (Two Micron All Sky Survey) Redshift Survey (2MRS) Ks ≤11.75 mag data release to test for physical association of candidate companion quasars with putative parent galaxies by virtue of Karlsson periodicity in quasar redshifts. We conducted this analysis using the quasar family detection algorithm described in Fulton and Arp (Astrophys. J. 754:134, 2012) and used therein to analyze the 2dF Galaxy Redshift Survey (2dFGRS) and the 2dF Quasar Redshift Survey (2QZ). The SDSS and 2MRS data sets confirm the 2dF results and allow us to examine additional object behaviors also at high significance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1986-02-01
This Environmental Assessment (EA) supports the DOE proposal to Congress to construct and operate a facility for monitored retrievable storage (MRS) of spent fuel at a site on the Clinch River in the Roane County portion of Oak Ridge, Tennessee. The first part of this document is an assessment of the value of, need for, and feasibility of an MRS facility as an integral component of the waste management system. The second part is an assessment and comparison of the potential environmental impacts projected for each of six site-design combinations. The MRS facility would be centrally located with respect tomore » existing reactors, and would receive and canister spent fuel in preparation for shipment to and disposal in a geologic repository. 207 refs., 57 figs., 132 tabs.« less
Lacasse, M-C; Tang, A; Dubois, J; Alvarez, F; Spahis, S; Chagnon, M; Deschênes, S; Levy, E
2017-06-01
To determine the effects of omega-3 supplementation on liver fat and carotid intima-media thickness (IMT) and to assess accuracy of ultrasound (US) for grading liver steatosis. In this one-way crossover pilot study, we assigned children with obesity and liver steatosis to receive 1.2 g daily of omega-3 supplementation vs. inactive sunflower oil for 24 or 12 weeks. Liver fat content was assessed by magnetic resonance spectroscopy (MRS), magnetic resonance imaging (MRI) and US, and common carotid IMT by US. Statistical analysis included Chi-square, Student's t -tests, ANOVA tests and receiver operating characteristic (ROC) curves. Omega-3 supplementation was associated with a trend towards decrease in MRS-determined liver fat fraction (0.7% and 2.1% decrease in the 24-week and 12-week omega-3 group, respectively) compared with the sunflower oil group (1.0% increase). These changes were not significant, whether assessed by MRS ( P = 0.508), MRI ( P = 0.508) or US ( P = 0.678). Using US, the area under the ROC curves were 0.964, 0.817 and 0.783 for distinguishing inferred steatosis grades 0 vs. 1-2-3, 0-1 vs. 2-3 and 0-1-2 vs. 3, respectively, indicating good accuracy of US-based fat grading. Omega-3 supplementation was associated with a decrease in US-determined IMT (0.05-mm decrease in the 24-week omega-3 group. A 0.015-mm increase was found in the 12-week omega-3 group, and a 0.007-mm decrease in the sunflower oil group ( P = 0.003). Omega-3 supplementation had no significant effect on liver fat fraction, but led to carotid IMT decrease in children with obesity and liver steatosis.
iSAP: Interactive Sparse Astronomical Data Analysis Packages
NASA Astrophysics Data System (ADS)
Fourt, O.; Starck, J.-L.; Sureau, F.; Bobin, J.; Moudden, Y.; Abrial, P.; Schmitt, J.
2013-03-01
iSAP consists of three programs, written in IDL, which together are useful for spherical data analysis. MR/S (MultiResolution on the Sphere) contains routines for wavelet, ridgelet and curvelet transform on the sphere, and applications such denoising on the sphere using wavelets and/or curvelets, Gaussianity tests and Independent Component Analysis on the Sphere. MR/S has been designed for the PLANCK project, but can be used for many other applications. SparsePol (Polarized Spherical Wavelets and Curvelets) has routines for polarized wavelet, polarized ridgelet and polarized curvelet transform on the sphere, and applications such denoising on the sphere using wavelets and/or curvelets, Gaussianity tests and blind source separation on the Sphere. SparsePol has been designed for the PLANCK project. MS-VSTS (Multi-Scale Variance Stabilizing Transform on the Sphere), designed initially for the FERMI project, is useful for spherical mono-channel and multi-channel data analysis when the data are contaminated by a Poisson noise. It contains routines for wavelet/curvelet denoising, wavelet deconvolution, multichannel wavelet denoising and deconvolution.
NASA Astrophysics Data System (ADS)
Pico, Rene Antonio, II
The purpose of this study was to investigate how teachers perceived and used performance assessment in the science classroom. Ms. Sanchez, Mrs. Irizarry, and Mrs. Bonnin, seventh grade teachers, participated in the study. Five research questions regarding the use of performance assessment were generated from these areas of inquiry: (a) teachers' views, (b) teachers' concerns, (c) teachers' level of use, (d) teachers' perceived facilitators, and (e) teachers' perceived barriers. Qualitative research methodologies were employed to collect and analyze the data. These included the use of informal interviews, a demographic survey, the Stage of Concern Questionnaire (Hall, George and Rutherford, 1979), the Level of Use Interview protocol (Loucks et al., 1975) and the study of artifacts. Performance assessment was defined by the three teachers as a dynamic process requiring the use of manipulatives in which students are involved as working participants in their own learning. Mrs. Irizarry and Mrs. Bonnin, described performance assessment with a broader range of possible executions, implying the use of tasks that allowed teachers to observe student behavior ranging from simple written responses to work collected over time. Ms. Sanchez defined assessment mainly on the basis of the use of equipment, instruments and materials in science. Ms. Sanchez reflected low intensity in the Levels of Concerns (Hall, George and Rutherford, 1979), suggesting that she felt at ease when working with performance assessment. Mrs. Irizarry and Mrs. Bonnin reflected definite commitment with the innovation. A major similarity was found in the areas of Refocusing (SoC 6), and Collaboration (SoC 5) denoting an interest in exploring and trying new alternatives. Ms. Sanchez and Mrs. Bonnin demonstrated characteristics of a well established routine or pattern in the Level of Use (Loucks et al., 1975) of performance assessment, while Mrs. Irizarry explored alternatives further and established a stronger process of modification. Two major facilitators to the use of performance assessment were perceived: (a) the provision of equipment and materials by the project; and (b) the support of colleagues. Two major barriers were perceived: (a) the time required to implement the tasks; and (b) the students' lack of knowledge and experience executing tasks.
NASA Astrophysics Data System (ADS)
Makarov, Vladimir; Kurkin, Andrey; Belyalov, Vladimir; Tyugin, Dmitry; Zezyulin, Denis
2017-04-01
The increase in spatial scales of studying coastal areas can be achieved by the use of mobile robotic systems (MRS) equipped with scanning equipment, video inspection system and positioning system. The project aims at increasing the capabilities for designing effective ground MRS through the use of advanced methods of forecasting characteristics of vehicle-terrain interaction in coastal zones, where hydrosphere, lithosphere, atmosphere and biosphere interact. In the period from 14 May to 18 June 2016 there was organized the expedition to Sakhalin Island for conducting full-scale testing autonomous MRS for coastal monitoring and forecasting marine natural disasters [Kurkin A.A., Zeziulin D.V., Makarov V.S., Zaitsev A.I., Belyaev A.M., Beresnev P.O., Belyakov V.V., Pelinovsky E.N., Tyugin D.Yu. Investigations of coastal areas of the Okhotsk sea using a ground mobile robot // Ecological systems and devices. 2016. No. 8. P. 11-17]. Within the framework of the expedition specific areas of terrain in the vicinity of Cape Svobodny were investigated (with the support of SRB AMR FEB RAS). Terrain areas were studied from the standpoint of possibility of the MRS movement. As a result of measuring all the necessary data on the physical-mechanical and geometric characteristics of the coastal zones, required to calculate the force factors acting on the MRS, and, accordingly, the parameters of its motion were received. The obtained data will be used for developing new statistical models of the physical-mechanical and geometrical characteristics of the coastal ground surfaces, creating methodology for assessing the efficiency and finding ways to optimize the design of the MRS.
Yi, Xiaofeng; Zhang, Jian; Fan, Tiehu; Tian, Baofeng; Jiang, Chuandong
2018-03-13
Magnetic resonance sounding (MRS) is a novel geophysical method to detect groundwater directly. By applying this method to underground projects in mines and tunnels, warning information can be provided on water bodies that are hidden in front prior to excavation and thus reduce the risk of casualties and accidents. However, unlike its application to ground surfaces, the application of MRS to underground environments is constrained by the narrow space, quite weak MRS signal, and complex electromagnetic interferences with high intensities in mines. Focusing on the special requirements of underground MRS (UMRS) detection, this study proposes the use of an antenna with different turn numbers, which employs a separated transmitter and receiver. We designed a stationary coil with stable performance parameters and with a side length of 2 m, a matching circuit based on a Q-switch and a multi-stage broad/narrowband mixed filter that can cancel out most electromagnetic noise. In addition, noises in the pass-band are further eliminated by adopting statistical criteria and harmonic modeling and stacking, all of which together allow weak UMRS signals to be reliably detected. Finally, we conducted a field case study of the UMRS measurement in the Wujiagou Mine in Shanxi Province, China, with known water bodies. Our results show that the method proposed in this study can be used to obtain UMRS signals in narrow mine environments, and the inverted hydrological information generally agrees with the actual situation. Thus, we conclude that the UMRS method proposed in this study can be used for predicting hazardous water bodies at a distance of 7-9 m in front of the wall for underground mining projects.
Yi, Xiaofeng; Fan, Tiehu; Tian, Baofeng
2018-01-01
Magnetic resonance sounding (MRS) is a novel geophysical method to detect groundwater directly. By applying this method to underground projects in mines and tunnels, warning information can be provided on water bodies that are hidden in front prior to excavation and thus reduce the risk of casualties and accidents. However, unlike its application to ground surfaces, the application of MRS to underground environments is constrained by the narrow space, quite weak MRS signal, and complex electromagnetic interferences with high intensities in mines. Focusing on the special requirements of underground MRS (UMRS) detection, this study proposes the use of an antenna with different turn numbers, which employs a separated transmitter and receiver. We designed a stationary coil with stable performance parameters and with a side length of 2 m, a matching circuit based on a Q-switch and a multi-stage broad/narrowband mixed filter that can cancel out most electromagnetic noise. In addition, noises in the pass-band are further eliminated by adopting statistical criteria and harmonic modeling and stacking, all of which together allow weak UMRS signals to be reliably detected. Finally, we conducted a field case study of the UMRS measurement in the Wujiagou Mine in Shanxi Province, China, with known water bodies. Our results show that the method proposed in this study can be used to obtain UMRS signals in narrow mine environments, and the inverted hydrological information generally agrees with the actual situation. Thus, we conclude that the UMRS method proposed in this study can be used for predicting hazardous water bodies at a distance of 7–9 m in front of the wall for underground mining projects. PMID:29534007
Mrs. B.'s Lakeside Restaurant (In the Classroom).
ERIC Educational Resources Information Center
Borysiewicz, Pat
1992-01-01
Describes how the author and her kindergarten students created a cooking center and restaurant in which they participate in regular cooking projects to provide opportunities to apply newly acquired skills in reading, writing, and math. (MG)
Promising Practices in Using the Internet to Teach Social Studies
ERIC Educational Resources Information Center
Risinger, C. Frederick
2006-01-01
This article presents several teachers and school Web sites that offer teaching strategies in using the Internet to teach social sciences. These Web sites include: (1) Mrs. Cori Culp's Website (www.bv229.k12.ks.us/bvw_culp); (2) Mr. Williams's 5th Grade(teachers.santee.k12.ca.us/cwilliams/index.htm); (3) Ms. Stewart's Classroom Page…
NASA Astrophysics Data System (ADS)
Viswanath, Satish; Tiwari, Pallavi; Rosen, Mark; Madabhushi, Anant
2008-03-01
Recently, in vivo Magnetic Resonance Imaging (MRI) and Magnetic Resonance Spectroscopy (MRS) have emerged as promising new modalities to aid in prostate cancer (CaP) detection. MRI provides anatomic and structural information of the prostate while MRS provides functional data pertaining to biochemical concentrations of metabolites such as creatine, choline and citrate. We have previously presented a hierarchical clustering scheme for CaP detection on in vivo prostate MRS and have recently developed a computer-aided method for CaP detection on in vivo prostate MRI. In this paper we present a novel scheme to develop a meta-classifier to detect CaP in vivo via quantitative integration of multimodal prostate MRS and MRI by use of non-linear dimensionality reduction (NLDR) methods including spectral clustering and locally linear embedding (LLE). Quantitative integration of multimodal image data (MRI and PET) involves the concatenation of image intensities following image registration. However multimodal data integration is non-trivial when the individual modalities include spectral and image intensity data. We propose a data combination solution wherein we project the feature spaces (image intensities and spectral data) associated with each of the modalities into a lower dimensional embedding space via NLDR. NLDR methods preserve the relationships between the objects in the original high dimensional space when projecting them into the reduced low dimensional space. Since the original spectral and image intensity data are divorced from their original physical meaning in the reduced dimensional space, data at the same spatial location can be integrated by concatenating the respective embedding vectors. Unsupervised consensus clustering is then used to partition objects into different classes in the combined MRS and MRI embedding space. Quantitative results of our multimodal computer-aided diagnosis scheme on 16 sets of patient data obtained from the ACRIN trial, for which corresponding histological ground truth for spatial extent of CaP is known, show a marginally higher sensitivity, specificity, and positive predictive value compared to corresponding CAD results with the individual modalities.
Solving a Health Information Management Problem. An international success story.
Hannan, Terry J
2015-01-01
The management of health care delivery requires the availability of effective 'information management' tools based on e-technologies [eHealth]. In developed economies many of these 'tools' are readily available whereas in Low and Middle Income Countries (LMIC) there is limited access to eHealth technologies and this has been defined as the "digital divide". This paper provides a short introduction to the fundamental understanding of what is meant by information management in health care and how it applies to all social economies. The core of the paper describes the successful implementation of appropriate information management tools in a resource poor environment to manage the HIV/AIDS epidemic and other disease states, in sub-Saharan Africa and how the system has evolved to become the largest open source eHealth project in the world and become the health information infrastructure for several national eHealth economies. The system is known as Open MRS [www.openmrs.org). The continuing successful evolution of the OpenMRS project has permitted its key implementers to define core factors that are the foundations for successful eHealth projects.
Photocopy of photograph (original photograph located in the Hawaii State ...
Photocopy of photograph (original photograph located in the Hawaii State Archives, Admiral Furlong Collection), HAS Neg. 199.016. U.S. Navy photograph, August 21, 1919. MRS. JOSEPHUS DANIELS, WIFE OF THE SECRETARY OF THE NAVY, PUSHED A BUTTON AND DRYDOCK NO. 1 (FACILITY S779) WAS OFFICIALLY INAUGURATED. - U.S. Naval Base, Pearl Harbor, Waterfront Facilities, Various locations throughout base, Pearl City, Honolulu County, HI
Development and Validation of the Nursing Home Minimum Data Set 3.0 Mortality Risk Score (MRS3).
Thomas, Kali S; Ogarek, Jessica A; Teno, Joan M; Gozalo, Pedro L; Mor, Vincent
2018-03-05
To develop a score to predict mortality using the Minimum Data Set 3.0 (MDS 3.0) that can be readily calculated from items collected during nursing home (NH) residents' admission assessments. We developed a training cohort of Medicare beneficiaries newly admitted to U.S. NHs during 2012 (N=1,426,815) and a testing cohort from 2013 (N=1,160,964). Data came from the MDS 3.0 assessments linked to the Medicare Beneficiary Summary File. Using the training dataset, we developed a composite MDS 3.0 Mortality Risk Score (MRS3) consisting of 17 clinical items and patients' age groups based on their relation to 30-day mortality. We assessed the calibration and discrimination of the MRS3 in predicting 30-day and 60-day mortality and compared its performance to the Charlson Comorbidity Index and the clinician's assessment of 6-month prognosis measured at admission. The 30-day and 60-day mortality rate for the testing population was 2.8% and 5.6%, respectively. Results from logistic regression models suggest that the MRS3 performed well in predicting death within 30 and 60 days (C-Statistics of 0.744 (95%CL = 0.741, 0.747) and 0.709 (95%CL=0.706, 0.711), respectively). The MRS3 was a superior predictor of mortality compared to the Charlson Comorbidity Index (C-statistics of 0.611 (95%CL=0.607, 0.615) and 0.608 (95%CL=0.605, 0.610)) and the clinicians' assessments of patients' 6-month prognoses (C-statistics of 0.543 (95%CL=0.542, 0.545) and 0.528 (95%CL=0.527, 0.529). The MRS3 is a good predictor of mortality and can be useful in guiding decision-making, informing plans of care, and adjusting for patients' risk of mortality.
Hospital Variation in Functional Recovery After Stroke.
Bettger, Janet Prvu; Thomas, Laine; Liang, Li; Xian, Ying; Bushnell, Cheryl D; Saver, Jeffrey L; Fonarow, Gregg C; Peterson, Eric D
2017-01-01
Functional status is a key patient-centric outcome, but there are little data on whether functional recovery post-stroke varies among hospitals. This study examined the distribution of functional status 3 months after stroke, determined whether these outcomes vary among hospitals, and identified hospital characteristics associated with better (or worse) functional outcomes. Observational analysis of the AVAIL study (Adherence Evaluation After Ischemic Stroke-Longitudinal) included 2083 ischemic stroke patients enrolled from 82 US hospitals participating in Get With The Guidelines-Stroke and AVAIL. The primary outcome was dependence or death at 3 months (modified Rankin Scale [mRS] score of 3-6). Secondary outcomes included functional dependence (mRS score of 3-5), disabled (mRS score of 2-5), and mRS evaluated as a continuous score. By 3 months post-discharge, 36.5% of patients were functionally dependent or dead. Rates of dependence or death varied widely by discharging hospitals (range: 0%-67%). After risk adjustment, patients had lower rates of 3-month dependence or death when treated at teaching hospitals (odds ratio, 0.72; 95% confidence interval, 0.54-0.96) and certified primary stroke centers (odds ratio, 0.69; 95% confidence interval, 0.53-0.91). In contrast, a composite measure of hospital-level adherence to acute stroke care performance metrics, stroke volume, and bed size was not associated with downstream patient functional status. Findings were robust across mRS end points and sensitivity analyses. One third of acute ischemic stroke patients were functionally dependent or dead 3 months postacute stroke; functional recovery rates varied considerably among hospitals, supporting the need to better determine which care processes can maximize functional outcomes. © 2017 American Heart Association, Inc.
An intergeneric hybrid wood warbler (Seiurus x Dendroica)
Short, L.L.; Robbins, Chandler S.
1967-01-01
Wild hybrid birds are always of interest with regard to our understanding of the variation encountered in nature. They may also be of ore or less taxonomic significance, depending on the frequency of their occurrence and other factors. We herein report and describe an apparent hybrid Northern Waterthrush (Seiurus noveboracensis) x Blackpoll Warbler (Dendroica striata) taken by Robbins at Ocean City, Maryland, on 17 September 1965. The bird (U.S. National Museum, no. 481595), an immature male with no fat, weighed 13.7 g and had apparently normal testes, each measuring 2.0 x 0.5 mm. The hybrid was taken in a net situated close to the ground, inland from the beach north of Ocean City; both Northern Waterthrushes and Blackpoll Warblers were caught the same day in the same net.The hybrid has the general appearance of a large, dark, immature wood warbler of the genus Dendroica. It shows a peculiar color pattern – it is streaked on its breast somewhat like a Cape May Warbler (D. tigrine), is dark olive with indistinct streaks on its back, and has distinct buffy superciliary stripes, narrowly barred wings, a yellowish white abdomen, long white under tail coverts, and an almost unmarked dark tail. The specimen resembles a Blackpoll Warbler in the length of its wings, tail, and bill, but it has longer legs and toes than members of that species.We are indebted to Mrs. Roxie C. Laybourne, David Bridge, and Paul Slud for useful suggestions, and to Kenneth C. Parkes for a helpful reading of the manuscript. The birds were banded at the Operation Recovery banding station by Robbins, Mrs. Richard D. Cole, Mrs. Herbert M. Church, William S. Clark, Mr. and Mrs. Herman F. Kuch, and Mr. and Mrs. Aldridge pepper.
75 FR 67985 - Government-Owned Inventions; Availability for Licensing
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-04
... spectrum data, recalibrates and scales the normalized MRS spectrum data, and then renormalizes the scaled MRS spectrum data. The resulting preprocessed MRS data is used to assist in identifying abnormalities in tissues shown in MRS scans. Raw MRS spectrum data and scaling the raw MRS spectrum data is...
Getting in on the act: the hysterical solution.
Britton, R
1999-02-01
The author recounts the case of Anna O from a contemporary psychoanalytic viewpoint, incorporating the additional information now available to us about Breuer's treatment of Bertha Pappenheim. Now the erotic transference and Anna O's 'oedipal illusion', which culminated in her hysterical pregnancy and labour, is evident to us, as it was to Freud, who did not publicly share his knowledge of Breuer's unhappy experience with this patient. Ernest Jones, in whom Freud did confide, wrongly dated the conception of the Breuer's baby in his biography of Freud describing it as a sequel to Anna O's treatment. In fact Mrs Breuer's pregnancy was concurrent with the treatment and the author suggests that it significantly influenced its course. Using the case of Anna O and one of his own the author postulates that a feature of hysteria is the use of projective identification by the patient to become in phantasy one or other member of the primal couple. A symbolic version of the primal scene between patient and analyst may then be enacted in the context of the erotic transference-countertransference that characterises these cases.
ERIC Educational Resources Information Center
Rosen, Connie; Rosen, Harold
1974-01-01
Excepts from THE LANGUAGE OF PRIMARY SCHOOL CHILDREN (Penguin, 1973), which evolved from a project initiated by the English Committee of the Schools Council of England and conducted under the direction of Mrs. Connie Rosen; focuses on the talk of primary school children in the presence of a teacher. (Author/JM)
2008 Preserve America Presidential Awards
Project, New York, New York; Corinth and Alcorn County Mississippi Heritage Tourism Initiative; Lower East and Alcorn County Mississippi Heritage Tourism Initiative were Rosemary Williams, Chairperson, Siege Heritage Tourism Initiative Mrs. Laura Bush poses for a photo with Preserve America Presidential Award
Kass, Mason A.; Bloss, Benjamin R.; Irons, Trevor P.; Cannia, James C.; Abraham, Jared D.
2014-01-01
This report is a release of digital data and associated survey descriptions from a series of magnetic resonance soundings (MRS, also known as surface nuclear magnetic resonance) that was conducted during October and November of 2012 in areas of western Nebraska as part of a cooperative hydrologic study by the North Platte Natural Resource District (NRD), South Platte NRD, Twin Platte NRD, the Nebraska Environmental Trust, and the U.S. Geological Survey (USGS). The objective of the study was to delineate the base-of-aquifer and refine the understanding of the hydrologic properties in the aquifer system. The MRS technique non-invasively measures water content in the subsurface, which makes it a useful tool for hydrologic investigations in the near surface (up to depths of approximately 150 meters). In total, 14 MRS production-level soundings were acquired by the USGS over an area of approximately 10,600 square kilometers. The data are presented here in digital format, along with acquisition information, survey and site descriptions, and metadata.
Processing and Fabrication of High Temperature Oxide Superconductors
1992-11-30
I. Gusman and S. M. Johnson, "Cryochemical Method of Preparing Ultrafine Particles of High-Purity Superconducting Oxides," U.S. Patent 4,975,415...Supercon- PREPARING ULTRAFINE PARTICLES OF ducting-MRS EA 11, Apr. 1987, pp. 265-267. HIGH-PURITY SUPERCONDUCTING Materials and Processing Report vol. 2, No... ULTRAFINE PARTICLES OF HIGH-PURITY A. W. Sleight in U.S. Pa&. No. 3,932.315 discloses SUPERCONDUCTING OXIDES superconductive barium-lead-bismuth oxides of
Chaisinanunkul, Napasri; Adeoye, Opeolu; Lewis, Roger J.; Grotta, James C.; Broderick, Joseph; Jovin, Tudor G.; Nogueira, Raul G.; Elm, Jordan; Graves, Todd; Berry, Scott; Lees, Kennedy R.; Barreto, Andrew D.; Saver, Jeffrey L.
2015-01-01
Background and Purpose Although the modified Rankin Scale (mRS) is the most commonly employed primary endpoint in acute stroke trials, its power is limited when analyzed in dichotomized fashion and its indication of effect size challenging to interpret when analyzed ordinally. Weighting the seven Rankin levels by utilities may improve scale interpretability while preserving statistical power. Methods A utility weighted mRS (UW-mRS) was derived by averaging values from time-tradeoff (patient centered) and person-tradeoff (clinician centered) studies. The UW-mRS, standard ordinal mRS, and dichotomized mRS were applied to 11 trials or meta-analyses of acute stroke treatments, including lytic, endovascular reperfusion, blood pressure moderation, and hemicraniectomy interventions. Results Utility values were: mRS 0–1.0; mRS 1 - 0.91; mRS 2 - 0.76; mRS 3 - 0.65; mRS 4 - 0.33; mRS 5 & 6 - 0. For trials with unidirectional treatment effects, the UW-mRS paralleled the ordinal mRS and outperformed dichotomous mRS analyses. Both the UW-mRS and the ordinal mRS were statistically significant in six of eight unidirectional effect trials, while dichotomous analyses were statistically significant in two to four of eight. In bidirectional effect trials, both the UW-mRS and ordinal tests captured the divergent treatment effects by showing neutral results whereas some dichotomized analyses showed positive results. Mean utility differences in trials with statistically significant positive results ranged from 0.026 to 0.249. Conclusion A utility-weighted mRS performs similarly to the standard ordinal mRS in detecting treatment effects in actual stroke trials and ensures the quantitative outcome is a valid reflection of patient-centered benefits. PMID:26138130
NASA Astrophysics Data System (ADS)
Li, Ningzhi; Li, Shizhe; Shen, Jun
2017-06-01
In vivo 13C magnetic resonance spectroscopy (MRS) is a unique and effective tool for studying dynamic human brain metabolism and the cycling of neurotransmitters. One of the major technical challenges for in vivo 13C-MRS is the high radio frequency (RF) power necessary for heteronuclear decoupling. In the common practice of in vivo 13C-MRS, alkanyl carbons are detected in the spectra range of 10-65ppm. The amplitude of decoupling pulses has to be significantly greater than the large one-bond 1H-13C scalar coupling (1JCH=125-145 Hz). Two main proton decoupling methods have been developed: broadband stochastic decoupling and coherent composite or adiabatic pulse decoupling (e.g., WALTZ); the latter is widely used because of its efficiency and superb performance under inhomogeneous B1 field. Because the RF power required for proton decoupling increases quadratically with field strength, in vivo 13C-MRS using coherent decoupling is often limited to low magnetic fields (<= 4 Tesla (T)) to keep the local and averaged specific absorption rate (SAR) under the safety guidelines established by the International Electrotechnical Commission (IEC) and the US Food and Drug Administration (FDA). Alternately, carboxylic/amide carbons are coupled to protons via weak long-range 1H-13C scalar couplings, which can be decoupled using low RF power broadband stochastic decoupling. Recently, the carboxylic/amide 13C-MRS technique using low power random RF heteronuclear decoupling was safely applied to human brain studies at 7T. Here, we review the two major decoupling methods and the carboxylic/amide 13C-MRS with low power decoupling strategy. Further decreases in RF power deposition by frequency-domain windowing and time-domain random under-sampling are also discussed. Low RF power decoupling opens the possibility of performing in vivo 13C experiments of human brain at very high magnetic fields (such as 11.7T), where signal-to-noise ratio as well as spatial and temporal spectral resolution are more favorable than lower fields.
The Importance of Enduring Partnership Between the US and Pakistan in Combating Terrorism
2008-01-01
Hundreds of Pakistanis including armed forces members have so far been killed in these terrorist attacks. The most high profile personality that has so...far been killed in such attacks was Mrs Benazir Bhutto, Pakistan’s ex Prime Minister. Pakistan has so far provided following assistance to the US: a...Pakistan Army conducted operation in South Waziristan in 2004, during which 302 militants were killed while 656 were detained. Some 80% of these
AccessMRS: integrating OpenMRS with smart forms on Android.
Fazen, Louis E; Chemwolo, Benjamin T; Songok, Julia J; Ruhl, Laura J; Kipkoech, Carolyne; Green, James M; Ikemeri, Justus E; Christoffersen-Deb, Astrid
2013-01-01
We present a new open-source Android application, AccessMRS, for interfacing with an electronic medical record system (OpenMRS) and loading 'Smart Forms' on a mobile device. AccessMRS functions as a patient-centered interface for viewing OpenMRS data; managing patient information in reminders, task lists, and previous encounters; and launching patient-specific 'Smart Forms' for electronic data collection and dissemination of health information. We present AccessMRS in the context of related software applications we developed to serve Community Health Workers, including AccessInfo, AccessAdmin, AccessMaps, and AccessForms. The specific features and design of AccessMRS are detailed in relationship to the requirements that drove development: the workflows of the Kenyan Ministry of Health Community Health Volunteers (CHVs) supported by the AMPATH Primary Health Care Program. Specifically, AccessMRS was designed to improve the quality of community-based Maternal and Child Health services delivered by CHVs in Kosirai Division. AccessMRS is currently in use by more than 80 CHVs in Kenya and undergoing formal assessment of acceptability, effectiveness, and cost.
Chaisinanunkul, Napasri; Adeoye, Opeolu; Lewis, Roger J; Grotta, James C; Broderick, Joseph; Jovin, Tudor G; Nogueira, Raul G; Elm, Jordan J; Graves, Todd; Berry, Scott; Lees, Kennedy R; Barreto, Andrew D; Saver, Jeffrey L
2015-08-01
Although the modified Rankin Scale (mRS) is the most commonly used primary end point in acute stroke trials, its power is limited when analyzed in dichotomized fashion and its indication of effect size challenging to interpret when analyzed ordinally. Weighting the 7 Rankin levels by utilities may improve scale interpretability while preserving statistical power. A utility-weighted mRS (UW-mRS) was derived by averaging values from time-tradeoff (patient centered) and person-tradeoff (clinician centered) studies. The UW-mRS, standard ordinal mRS, and dichotomized mRS were applied to 11 trials or meta-analyses of acute stroke treatments, including lytic, endovascular reperfusion, blood pressure moderation, and hemicraniectomy interventions. Utility values were 1.0 for mRS level 0; 0.91 for mRS level 1; 0.76 for mRS level 2; 0.65 for mRS level 3; 0.33 for mRS level 4; 0 for mRS level 5; and 0 for mRS level 6. For trials with unidirectional treatment effects, the UW-mRS paralleled the ordinal mRS and outperformed dichotomous mRS analyses. Both the UW-mRS and the ordinal mRS were statistically significant in 6 of 8 unidirectional effect trials, whereas dichotomous analyses were statistically significant in 2 to 4 of 8. In bidirectional effect trials, both the UW-mRS and ordinal tests captured the divergent treatment effects by showing neutral results, whereas some dichotomized analyses showed positive results. Mean utility differences in trials with statistically significant positive results ranged from 0.026 to 0.249. A UW-mRS performs similar to the standard ordinal mRS in detecting treatment effects in actual stroke trials and ensures the quantitative outcome is a valid reflection of patient-centered benefits. © 2015 American Heart Association, Inc.
MX Resident Engineer Networking Guide.
1982-04-01
FIGURES 6 INTRODUCTION ............................................................ 11 Background Approach Purpose Scope 2 SYSTEM OVERVIEW...RESIDENT ENGINEER NETWORKING GUIDE 1 INTRODUCTION Background The Network Analysis System (NAS) is not a new planning method. It has been used for more than...DEVELOPMENT RUN DATE 19MAY7’ 2359MRS S U M M A R I P A Y N L N T S S T A I I M E N I PROJECT START jAUG ?? PROJECT EXR 4 L1 SAMPLE PNOPLEM *ACTIVITT-YN
Costantino, Claudio; Albeggiani, Valentina; Bonfante, Maria Stefania; Monte, Caterina; Lo Cascio, Nunzio; Mazzucco, Walter
2015-02-10
Among health care workers (HCWs), work-related stress is one of the main topics in risk assessment and prevention at the workplace. Post-graduate medical residents (MRs) are a group of HCWs comparable to medical doctors in terms of occupational exposure and occurrence of work-related stress syndromes. Risk assessment of work-related stress among MRs attending the major University Hospital of Sicily. A cross-sectional survey via an anonymous and self-administered questionnaire. 45% of clinical MRs and 37% of surgical MRs had access to compensatory rest days against 92% of MRs of the services area (p<0.001). A work attendance recording system for MRs was available in 80% of the postgraduate medical schools of the services area, in 60% of the clinical postgraduate schools and in 50% of the surgical postgraduate schools (p<0.001). MRs of the postgraduate surgical schools reported having access to work breaks (41%) with less frequency compared to clinical (60%) and services MRs (74%) (p<0.001). Both clinical (47%) and surgical MRs (47%) were more exposed to work-related stress than MRs of the services area (27%) (p<0.001). The survey demonstrated excess exposure to work-related stress for all the considered variables in MRs of the surgical area, compared with MRs of clinical and services areas. It is strongly recommended to provide specific training programmes aimed at managing the MRs' risk of exposure to work-related stress, focusing both on the workers and the work environment.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-02
... Engineering Command Northwest, 1101 Tautog Circle, Suite 203, Silverdale, WA 98315-1101, Attn: NWSTF Boardman... mailed to Naval Facilities Engineering Command Northwest, Attention: Mrs. Amy Burt, NWSTF Boardman EIS Project Manager, Naval Facilities Engineering Command Northwest, 1101 Tautog Circle, Suite 203, Silverdale...
ACHP | News | Mrs. Laura Bush Designates Corinth, Mississippi, a Preserve
; notification to media, state tourism offices, and visitor bureaus; and listing on a Web-based directory to showcase preservation efforts and highlight heritage tourism destinations. The Bush Administration's fiscal promotion of heritage tourism and other economic revitalization projects. John L. Nau, III, chairman of the
Yoon, Haesung; Yoon, Dahye; Yun, Mijin; Choi, Ji Soo; Park, Vivian Youngjean; Kim, Eun-Kyung; Jeong, Joon; Koo, Ja Seung; Yoon, Jung Hyun; Moon, Hee Jung; Kim, Suhkmann; Kim, Min Jung
2016-01-01
Our goal in this study was to find correlations between breast cancer metabolites and conventional quantitative imaging parameters using high-resolution magic angle spinning (HR-MAS) magnetic resonance spectroscopy (MRS) and to find breast cancer subgroups that show high correlations between metabolites and imaging parameters. Between August 2010 and December 2013, we included 53 female patients (mean age 49.6 years; age range 32-75 years) with a total of 53 breast lesions assessed by the Breast Imaging Reporting and Data System. They were enrolled under the following criteria: breast lesions larger than 1 cm in diameter which 1) were suspicious for malignancy on mammography or ultrasound (US), 2) were pathologically confirmed to be breast cancer with US-guided core-needle biopsy (CNB) 3) underwent 3 Tesla MRI with dynamic contrast-enhanced (DCE) and diffusion-weighted imaging (DWI) and positron emission tomography-computed tomography (PET-CT), and 4) had an attainable immunohistochemistry profile from CNB. We acquired spectral data by HR-MAS MRS with CNB specimens and expressed the data as relative metabolite concentrations. We compared the metabolites with the signal enhancement ratio (SER), maximum standardized FDG uptake value (SUV max), apparent diffusion coefficient (ADC), and histopathologic prognostic factors for correlation. We calculated Spearman correlations and performed a partial least squares-discriminant analysis (PLS-DA) to further classify patient groups into subgroups to find correlation differences between HR-MAS spectroscopic values and conventional imaging parameters. In a multivariate analysis, the PLS-DA models built with HR-MAS MRS metabolic profiles showed visible discrimination between high and low SER, SUV, and ADC. In luminal subtype breast cancer, compared to all cases, high SER, ADV, and SUV were more closely clustered by visual assessment. Multiple metabolites were correlated with SER and SUV in all cases. Multiple metabolites showed correlations with SER and SUV in the ER positive, HER2 negative, and Ki-67 negative groups. High levels of PC, choline, and glycine acquired from HR-MAS MRS using CNB specimens were noted in the high SER group via DCE MRI and the high SUV group via PET-CT, with significant correlations between choline and SER and between PC and SUV. Further studies should investigate whether HR-MAS MRS using CNB specimens can provide similar or more prognostic information than conventional quantitative imaging parameters.
Self-Reported Minimalist Running Injury Incidence and Severity: A Pilot Study.
Ostermann, Katrina; Ridpath, Lance; Hanna, Jandy B
2016-08-01
Minimalist running entails using shoes with a flexible thin sole and is popular in the United States. Existing literature disagrees over whether minimalist running shoes (MRS) improve perceived severity of injuries associated with running in traditional running shoes (TRS). Additionally, the perceived injury patterns associated with MRS are relatively unknown. To examine whether injury incidence and severity (ie, degree of pain) by body region change after switching to MRS, and to determine if transition times affect injury incidences or severity with MRS. Runners who were either current or previous users of MRS were recruited to complete an Internet-based survey regarding self-reported injury before switching to MRS and whether self-reported pain from that injury decreased after switching. Questions regarding whether new injuries developed in respondents after switching to MRS were also included. Analyses were calculated using t tests, Wilcoxon signed rank tests, and Fischer exact tests. Forty-seven runners completed the survey, and 16 respondents reported injuries before switching to MRS. Among these respondents, pain resulting from injuries of the feet (P=.03) and knees (P=.01) decreased. Eighteen respondents (38.3%) indicated they sustained new injuries after switching to MRS, but the severity of these did not differ significantly from no injury. Neither time allowed for transition to MRS nor use or disuse of a stretching routine during this period was correlated with an increase in the incidence or severity of injuries. After switching to MRS, respondents perceived an improvement in foot and knee injuries. Additionally, respondents using MRS reported an injury rate of 38.3%, compared with the approximately 64% that the literature reports among TRS users. Future studies should be expanded to determine the full extent of the differences in injury patterns between MRS and TRS.
Watkins: Store spent fuel at federal sites
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tompkins, B.
If the Department of Energy under the Clinton Administration decides to follow the strategy of departing Energy Secretary James Watkins, spent nuclear fuel (SNF) from utilities would be stored at federal sites starting in 1998. In what amounts to an admission that a monitored retrievable storage (MRS) facility will not be ready to accept SNF by 1998, Watkins proposed in a December 17 letter to Senator J. Bennett Johnston that current work on an MRS be terminated, and that efforts be redirected toward standardized spent-fuel container design. According to the DOE's Samantha Williams, however, the Waste Negotiator's Office will continuemore » its activities, and the new strategy is intended to supplement the ongoing MRS work. She also said that DOE Undersecretary Hugo Pomrehn confirmed this in a statement to the Nuclear Waste TEchnical Review Board during its meeting on January 5. The motivation for the new strategic actions is in part related to the passage of the National Energy Policy Act of 1992, which envisions the continued use of nuclear power in the overall US energy plan. Watkins points out, however, that in order for nuclear power to remain a viable alternative, the management and disposal of spent commercial nuclear fuel is essential to avoid premature and unwarranted shutdowns of operating nuclear plants, to permit renewals of existing plant licenses to provide life extensions from 40 to 60 years, and to enable new orders of advanced-design nuclear plants. In addition, the new strategy is required, according to Watkins, because the Office of the Nuclear Waste Negotiator has been unsuccessful in identifying a voluntary host site for an MRS after two years of efforts to that end. David Leroy, the Negotiator, disagrees with this statement, and has noted that it still may be possible to present a candidate host site for the MRS to Congress by June 1993.« less
14. Photocopy of 1872 photograph by Eadweard Muybridge in Stanford ...
14. Photocopy of 1872 photograph by Eadweard Muybridge in Stanford University Archives, PC 6. SEWING ROOM ('BIRD ROOM').LEFT TO RIGHT, ANNA MARIA LATHROP (MRS. STANFORD'S SISTER), MRS. JANE ANN (DYER) LATHROP (MRS. STANFORD'S MOTHER), ELIZABETH PHILLIPS (MRS. JOSIAH) STANFORD (GOV. STANFORD'S MOTHER), JANE LATHROP (MRS. LELAND) STANFORD AND HER SON, LELAND, JR. - Leland Stanford House, 800 N Street, Sacramento, Sacramento County, CA
The New Approach to Self-Achievement (N.A.S.A.) Project 2004
NASA Technical Reports Server (NTRS)
Thomas, Candace J.
2004-01-01
The New Approach to Self-Achievement Program is designed to target rising seventh, eighth, and ninth grade students who require assistance in refining their mathematical skills, science awareness and knowledge, and test taking strategies. During the six week duration of the program, students are challenged in these areas through the application of robotic and aeronautic projects which encourage the students to practically apply their mathematical and science awareness accordingly. The first three weeks of my tenure were designated to assisting Mrs. Tammy Allen in the preparation of the 2004 NASA Project. As her assistant, I was held accountable for organizing, filing, preparing, analyzing, and completing the applications for the NASA Project. Additionally, I constructed the apposite databases which contained imperative information which aided in the selection of our participants. During the latter portion of those three weeks, Mrs. Allen, various staff members, and I, interviewed the numerous first-time applicants of the NASA Project. Furthermore, I was assigned to contact the accepted applicants of the program and provide all necessary information for the initiation of the child into the NASA Project. During the six week duration of the program, I will be working as a Project Leader at the Lorain Middle School site located in Lorain, Oh, with Mr. Fondriest Fountain. Mr. Fountain and I Will work with the eighth and ninth grade students in constructing robots, in which the students are told are made for NASA research which is being conducted on the surface of planet Mars. The robots, which are built from LEGOS and programmed through RoboLab computer software, are prepared to complete assigned Missions such as running obstacle courses; plowing and retrieving LEGOS; and scanning surfaces for intense regions of light.
Microcomputer Interfaces with U.S. Marine Corps Tactical Communications Systems,
1991-04-01
Schneider and Mrs. Kirkpatrick at the Communications officer School Quantico, Virginia This document has been approvedf or p,bic Yleaze cncd sae; its...communications systems; however, there is not a comprehensive USMC Command, Control, Communications, and Computers (C4) operational policy that documents these...5-6 COMMUNICATIONS SYSTEMS .... ............. 5-6 ADP SYSTEMS ....... .................. 5-6 OPERATIONAL POLICIES
(Un)Official Knowledge and Identity: An Emerging Bilingual's Journey into Hybridity
ERIC Educational Resources Information Center
López-Robertson, Julia; Schramm-Pate, Susan
2013-01-01
Gabriela Montserrat (pseudonym) is a Mexican-American child classified by her school district as an "emerging bilingual" and is the focus of this qualitative case study that took place at a public elementary school located in a suburban community in the southwestern US in Mrs Pérez's (pseudonym) second-grade classroom. The student's use…
ERIC Educational Resources Information Center
Maskiewicz, April C.; Winters, Victoria A.
2012-01-01
We set out to understand how different instantiations of inquiry emerged in two different years of one elementary teacher's classroom. Longitudinal observations from Mrs. Charles' 5th grade science classroom forced us to carefully and deliberately consider who exactly was responsible for the change in the class activities and norms. We provide…
20 CFR 416.1166a - How we deem income to you from your sponsor if you are an alien.
Code of Federal Regulations, 2010 CFR
2010-04-01
.... Mr. and Mrs. Smith are an alien couple who have no income and who have been sponsored by Mr. Hart. Mr... $660. This amount must be deemed independently to Mr. and Mrs. Smith. Mr. and Mrs. Smith would qualify... ($660 each to Mr. and Mrs. Smith) deemed income is unearned income to Mr. and Mrs. Smith and is subject...
High-field MRS in clinical drug development.
Ross, Brian D
2013-07-01
Magnetic resonance spectroscopy (MRS) will continue to play an ever increasing role in drug discovery because MRS does readily define biomarkers for several hundreds of clinically distinct diseases. Published evidence based medicine (EBM) surveys, which generally conclude the opposite, are seriously flawed and do a disservice to the field of drug discovery. This article presents MRS and how it has guided several hundreds of practical human 'drug discovery' endeavors since its development. Specifically, the author looks at the process of 'reverse-translation' and its influence in the expansion of the number of preclinical drug discoveries from in vivo MRS. The author also provides a structured approach of eight criteria, including EBM acceptance, which could potentially re-open the field of MRS for productive exploration of existing and repurposed drugs and cost-effective drug-discovery. MRS-guided drug discovery is poised for future expansion. The cost of clinical trials has escalated and the use of biomarkers has become increasingly useful in improving patient selection for drug trials. Clinical MRS has uncovered a treasure-trove of novel biomarkers and clinical MRS itself has become better standardized and more widely available on 'routine' clinical MRI scanners. When combined with available new MRI sequences, MRS can provide a 'one stop shop' with multiple potential outcome measures for the disease and the drug in question.
Determining Intra-Theater Airlift Requirements from Number of Personnel Deployed in a Region
2013-06-01
providing the support, love and motivation to keep this project on track. vi Acknowledgments I would like to thank my advisor, Lt Col Sandlin...outstanding computer support, and Mrs. Pamela Bennett Bardot for the best research assistance that I have ever experienced. I couldn’t have completed this...xi I . Introduction .....................................................................................................................1
Cooray, Charith; Matusevicius, Marius; Wahlgren, Nils; Ahmed, Niaz
2015-10-01
In many countries, a majority of stroke patients are not assessed for long-term functional outcome owing to limited resources and time. We investigated whether automatic assessment of the modified Rankin Scale (mRS) based on a mobile phone questionnaire may serve as an alternative to mRS assessments at clinical visits after stroke. We enrolled 62 acute stroke patients admitted to our stroke unit during March to May 2014. Forty-eight patients completed the study. During the stay, patients and/or caregivers were equipped with a mobile phone application in their personal mobile phones. The mobile phone application contained a set of 20 questions, based on the Rankin Focused Assessment, which we previously tested in a pilot study. Three months after inclusion, the mobile phone application automatically prompted the study participants to answer the mRS questionnaire in the mobile phones. Each question or a group of questions in the questionnaire corresponded to a certain mRS score. Using a predefined protocol, the highest mRS score question where the study participant had answered yes was deemed the final mobile mRS score. A few days later, a study personnel performed a clinical visit mRS assessment. The 2 assessments were compared using quadratic weighing κ-statistics. Mean age was 67 years (38% females), and median baseline National Institutes of Health Stroke Scale (NIHSS) score was 5 (interquartile range 2-10.5, range 0-23). Median and mean clinical visit mRS at 3 months was 2 and 2.3, respectively. We found a 62.5% agreement between clinical visit and mobile mRS assessment, weighted kappa 0.89 (95% confidence interval 0.82-0.96), and unweighted kappa 0.53 (95% confidence interval 0.36-0.70). Dichotomized mRS outcome separating functionally independent (mRS score 0-2) from dependent (mRS score 3-5) showed 83% agreement and unweighted kappa of 0.66 (95% confidence interval 0.45-0.87). Mobile phone-based automatic assessments of mRS performed well in comparison with clinical visit mRS and could be used as an alternative in stroke follow-up. © 2015 American Heart Association, Inc.
16. Copy of a post card showing the Lavelle School, ...
16. Copy of a post card showing the Lavelle School, c.1900; note that the building is one story in height and contains a one story addition in the rear. It also contains a projecting entrance tower and the windows have shutters. There are no windows or chimneys on the west wall and the front yard is defined by a wood picket fence on the west side and a metal picket fence on the north side. The identities of the children standing near the door are not known. (Copy of photo reproduced with permission from the Ashland Public Library and Mrs. Helen Edling, former Postmaster of Lavelle {she currently resides in Lavelle}; the original photograph is in Mrs. Edling's collection) - Lavelle School, Township Road 905, Main Street, Village of Lavelle, Lavelle, Schuylkill County, PA
Research Applications of Magnetic Resonance Spectroscopy (MRS) to Investigate Psychiatric Disorders
Dager, SR; Oskin, NM; Richards, TL; Posse, S
2009-01-01
Advances in magnetic resonance spectroscopy (MRS) methodology and related analytic strategies allow sophisticated testing of neurobiological models of disease pathology in psychiatric disorders. An overview of principles underlying MRS, methodological considerations and investigative approaches is presented. A review of recent research is presented that highlights innovative approaches applying MRS, in particular 1H MRS, to systematically investigate specific psychiatric disorders, including autism spectrum disorders, schizophrenia, panic disorder, major depression and bipolar disorder. PMID:19363431
Fausto, A; Magaldi, A; Babaei Paskeh, B; Menicagli, L; Lupo, E N; Sardanelli, F
2007-10-01
The purpose of this study was to propose a short way to summarise a breast magnetic resonance (MR) examination including a precontrast and contrast-enhanced dynamic study and proton spectroscopy (1H-MRS) in order to convey the diagnostic message. At the Department of Radiology of the Policlinico San Donato (University of Milan), breast MR is routinely performed at 1.5 T as follows: 36-slice axial 2D short-time inversion-recovery (STIR) sequence; 128-partition 3D gradient-echo coronal sequence (1-mm3 siotropic voxel) before and after rapid automatic intravenous injection of 0.1 mmol/kg of Gd-DOTA (one precontrast and four postcontrast phases). Postprocessing includes temporal subtraction (postcontrast minus precontrast), maximum intensity projections (MIPs), percent enhancement-to-time curves for small regions of interest, and axial and/or sagittal multiplanar reconstructions. Single-voxel 1H-MRS is acquired to characterise focal lesions. Applying this protocol, more than 1,200 images are generated for each examination. We select only four MIPs of an early subtracted dynamic phase: one axial similar to craniocaudal x-ray mammographic views, one coronal, and two lateral similar to lateral 90 degrees x-ray mammographic views. For each lesion described in the report, we select five items, including three images, one graph, and one table: STIR image, precontrast and subtracted postcontrast images (morphology), percent enhancement-to-time curves and a table of raw data generating the curves (dynamics). If 1H-MRS has been performed, we add other five items: two postprocessed spectra (metabolism) and three images localising the volume of interest. Only the selected items are printed on films and attached to the report. The selected items range usually from four (no detected lesion) to 14 (one lesion, studied also with 1H-MRS), to 44 (five lesions, one of them studied also with 1H-MRS). The percentage of items presented with the report if compared with the total number of generated images is equal to 0.33% (4/1,200), 1.17% (14/1,200), and 2.83% (34/1,200), respectively. Breast MR imaging and 1H-MRS can be effectively summarised presenting only a minimal fraction of all generated images.
Fifty years of brain imaging in neonatal encephalopathy following perinatal asphyxia.
Groenendaal, Floris; de Vries, Linda S
2017-01-01
In the past brain imaging of term infants with hypoxic-ischemic encephalopathy (HIE) was performed with cranial ultrasound (cUS) and computed tomography (CT). Both techniques have several disadvantages sensitivity and specificity is limited compared with magnetic resonance imaging (MRI) and CT makes use of radiation. At present MRI including diffusion weighted MRI during the first week of life, has become the method of choice for imaging infants with HIE. In addition to imaging, blood vessels and blood flow can be visualized using MR angiography, MR venography, and arterial spin labeling. Since the use of these techniques additional lesions in infants with HIE, such as arterial ischemic stroke, sinovenous thrombosis, and subdural hemorrhages can be diagnosed, and the incidence appears to be higher than shown previously. Phosphorus magnetic resonance spectroscopy (MRS) has led to the concept of secondary energy failure in infants with HIE, but has not been widely used. Proton MRS of the basal ganglia and thalamus is one of the best predictors of neurodevelopmental outcome. cUS should still be used for screening infants admitted to a NICU with neonatal encephalopathy. In the future magnetic resonance techniques will be increasingly used as early biomarkers of neurodevelopmental outcome in trials of neuroprotective strategies.
Choi, Chi-Bong; Kim, Sang-Young; Lee, Sung-Ho; Jahng, Geon-Ho; Kim, Hwi-Yool; Choe, Bo-Young; Ryu, Kyung-Nam; Yang, Dal-Mo; Yim, Sung-Vin; Choi, Woo-Suk
2011-01-01
Parkinson's disease (PD) is a neurodegenerative disorder characterized by the progressive loss of the dopaminergic neurons in the substantia nigra pars compacta, which projects to the striatum. We induced a selective loss of nigrostriatal dopamine neurons, by infusing the mitochondrial complex 1 inhibitor 1-methyl 4-phenyl 1,2,3,6-tetrahydropyridine (MPTP) into adult beagle dogs (N=5). Single voxel ¹H water suppressed magnetic resonance spectroscopy (¹H-MRS) at 3 T was used to assess the metabolic changes in the striatum of canine before and after MPTP intoxication. The metabolite spectra obtained from the striatum (voxel size: 2 cm³) showed a lower N-acetyl aspartate to total creatine (creatine+phosphocreatine) ratio after MPTP intoxication. There were no significant differences in other metabolite ratios such as glutamate+glutamine, choline-containing compounds (glycerophosphocholine+phophorylcholine and myo-inositol). Our findings indicated that ¹H-MRS is a sensitive, noninvasive measure of neural toxicity and biochemical alterations of the striatum in a canine model of PD, and further studies are needed to confirm brain metabolic changes in association with progression of MPTP-intoxication. Copyright © 2011 Elsevier Inc. All rights reserved.
Ernst, Marielle; Boers, Anna M M; Aigner, Annette; Berkhemer, Olvert A; Yoo, Albert J; Roos, Yvo B; Dippel, Diederik W J; van der Lugt, Aad; van Oostenbrugge, Robert J; van Zwam, Wim H; Fiehler, Jens; Marquering, Henk A; Majoie, Charles B L M
2017-09-01
Ischemic lesion volume (ILV) assessed by follow-up noncontrast computed tomography correlates only moderately with clinical end points, such as the modified Rankin Scale (mRS). We hypothesized that the association between follow-up noncontrast computed tomography ILV and outcome as assessed with mRS 3 months after stroke is strengthened when taking the mRS relevance of the infarct location into account. An anatomic atlas with 66 areas was registered to the follow-up noncontrast computed tomographic images of 254 patients from the MR CLEAN trial (Multicenter Randomized Clinical Trial of Endovascular Treatment of Acute Ischemic Stroke in the Netherlands). The anatomic brain areas were divided into brain areas of high, moderate, and low mRS relevance as reported in the literature. Based on this distinction, the ILV in brain areas of high, moderate, and low mRS relevance was assessed for each patient. Binary and ordinal logistic regression analyses with and without adjustment for known confounders were performed to assess the association between the ILVs of different mRS relevance and outcome. The odds for a worse outcome (higher mRS) were markedly higher given an increase of ILV in brain areas of high mRS relevance (odds ratio, 1.42; 95% confidence interval, 1.31-1.55 per 10 mL) compared with an increase in total ILV (odds ratios, 1.16; 95% confidence interval, 1.12-1.19 per 10 mL). Regression models using ILV in brain areas of high mRS relevance instead of total ILV showed a higher quality. The association between follow-up noncontrast computed tomography ILV and outcome as assessed with mRS 3 months after stroke is strengthened by accounting for the mRS relevance of the affected brain areas. Future prediction models should account for the ILV in brain areas of high mRS relevance. © 2017 American Heart Association, Inc.
NASA Astrophysics Data System (ADS)
Legchenko, Anatoly; Miège, Clément; Koenig, Lora S.; Forster, Richard R.; Miller, Olivia; Solomon, D. K.; Schmerr, Nicholas; Montgomery, Lynn; Ligtenberg, Stefan; Brucker, Ludovic
2018-03-01
Recent observations of the Greenland ice sheet show an increase of the area affected by progressive melt of snow and ice, thus resulting in production of the additional meltwater. In 2011, an important storage of meltwater in the firn has been observed in the S-E Greenland. This water does not freeze during the wintertime and forms a perennial firn aquifer. The aquifer spatial extent has been initially monitored with combined ground and airborne radar observations, but these geophysical techniques are not able to inform us on the amount of meltwater stored at depth. In this study, we use the magnetic resonance soundings (MRS) method for estimating the volume of water stored in the Greenland ice sheet firn and mapping its spatial variability. Our study area covers a firn aquifer along a 16-km E-W transect, ranging between elevations of 1520 and 1760 m. In July 2015 and July 2016, we performed MRS measurements that allow estimating the water volume in the studied area as well as the one-year water volume evolution. Water storage is not homogeneous, fluctuating between 0.2 and 2 m3/m2, and contains discontinuities in the hydrodynamic properties. We estimate an average volume of water stored in the firn in 2016 to be 0.76 m3/m2, which corresponds to a 0.76-m-thick layer of bulk water. MRS monitoring reveals that from April 2015 to July 2016 the volume of water stored at the location of our transect increases by about 36%. We found MRS-estimated depth to water in a good agreement with that obtained with the ground penetrating radar (GPR).
Open Skies Project Computational Fluid Dynamic Analysis
1994-03-01
109 -. -_ _ 9 . CONCLUSIONSI1 f 10. LIST OF REFERENCES _________ ___________112 APPENDIX A: Transition Prediction __________________116 B...Behind the Open Skies Plate 20 8. VSAERO Results on the Alternate Fairing 21 9 . Centerline Cp Comparisons 22 10. VSAERO Wing Effects Study Centerline C...problems. The assistance Mrs. Mary Ann Mages, at Kirtland Supercomputer Center ( PL /SCPR) gave by setting a precedent for supercomputer account
Shield evaluation and performance testing at the USMB`s Strategic Structures Testing Laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barczak, T.M.; Gearhart, D.F.
1996-12-31
Historically, shield performance testing is conducted by the support manufacturers at European facilities. The U.S. Bureau of Mines (USBM) has conducted extensive research in shield Mechanics and is now opening its Strategic Structures Testing (SST) Laboratory to the mining industry for shield performance testing. The SST Laboratory provides unique shield testing capabilities using the Mine Roof Simulator (MRS) load frame. The MRS provides realistic and cost-effective shield evaluation by combining both vertical and horizontal loading into a single load cycle; whereas, several load cycles would be required to obtain this loading in a static frame. In addition to these advantages,more » the USBM acts as an independent research organization to provide an unbiased assessment of shield performance. This paper describes the USBM`s shield testing program that is designed specifically to simulate in-service mining conditions using the unique the capabilities of the SST Laboratory.« less
10 CFR 72.98 - Identifying regions around an ISFSI or MRS site.
Code of Federal Regulations, 2012 CFR
2012-01-01
... WASTE Siting Evaluation Factors § 72.98 Identifying regions around an ISFSI or MRS site. (a) The... ISFSI or MRS must be identified. (b) The potential regional impact due to the construction, operation or decommissioning of the ISFSI or MRS must be identified. The extent of regional impacts must be determined on the...
10 CFR 72.98 - Identifying regions around an ISFSI or MRS site.
Code of Federal Regulations, 2011 CFR
2011-01-01
... WASTE Siting Evaluation Factors § 72.98 Identifying regions around an ISFSI or MRS site. (a) The... ISFSI or MRS must be identified. (b) The potential regional impact due to the construction, operation or decommissioning of the ISFSI or MRS must be identified. The extent of regional impacts must be determined on the...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neuhauser, K.S.; Cashwell, J.W.; Reardon, P.C.
1986-12-31
This paper discusses the relative national environmental impacts of transporting nuclear wastes to each of the nine candidate repository sites in the United States. Several of the potential sites are closely clustered and, for the purpose of distance and routing calculations, are treated as a single location. These are: Cypress Creek Dome and Richton Dome in Mississippi (Gulf Interior Region), Deaf Smith County and Swisher County sites in Texas (Permian Basin), and Davis Canyon and Lavender Canyon site in Utah (Paradox Basin). The remaining sites are: Vacherie Dome, Louisiana; Yucca Mountain, Nevada; and Hanford Reservation, Washington. For compatibility with bothmore » the repository system authorized by the NWPA and with the MRS option, two separate scenarios were analyzed. In belief, they are (1) shipment of spent fuel and high-level wastes (HLW) directly from waste generators to a repository (Reference Case) and (2) shipment of spent fuel to a Monitored Retrievable Storage (MRS) facility and then to a repository. Between 17 and 38 truck accident fatalities, between 1.4 and 7.7 rail accident fatalities, and between 0.22 and 12 radiological health effects can be expected to occur as a result of radioactive material transportation during the 26-year operating period of the first repository. During the same period in the United States, about 65,000 total deaths from truck accidents and about 32,000 total deaths from rail accidents would occur; also an estimated 58,300 cancer fatalities are predicted to occur in the United States during a 26-year period from exposure to background radiation alone (not including medical and other manmade sources). The risks reported here are upper limits and are small by comparison with the "natural background" of risks of the same type. 3 refs., 6 tabs.« less
Karampinos, Dimitrios C.; Melkus, Gerd; Baum, Thomas; Bauer, Jan S.; Rummeny, Ernst J.; Krug, Roland
2013-01-01
Purpose The purpose of the present study was to test the relative performance of chemical shift-based water-fat imaging in measuring bone marrow fat fraction in the presence of trabecular bone, having as reference standard the single-voxel magnetic resonance spectroscopy (MRS). Methods Six-echo gradient echo imaging and single-voxel MRS measurements were performed on the proximal femur of seven healthy volunteers. The bone marrow fat spectrum was characterized based on the magnitude of measurable fat peaks and an a priori knowledge of the chemical structure of triglycerides, in order to accurately extract the water peak from the overlapping broad fat peaks in MRS. The imaging-based fat fraction results were then compared to the MRS-based results both without and with taking into consideration the presence of short T2* water components in MRS. Results There was a significant underestimation of the fat fraction using the MRS model not accounting for short T2* species with respect to the imaging-based water fraction. A good equivalency was observed between the fat fraction using the MRS model accounting for short T2* species and the imaging-based fat fraction (R2=0.87). Conclusion The consideration of the short T2* water species effect on bone marrow fat quantification is essential when comparing MRS-based and imaging-based fat fraction results. PMID:23657998
Achmad, Emil; Yokoo, Takeshi; Hamilton, Gavin; Heba, Elhamy R; Hooker, Jonathan C; Changchien, Christopher; Schroeder, Michael; Wolfson, Tanya; Gamst, Anthony; Schwimmer, Jeffrey B; Lavine, Joel E; Sirlin, Claude B; Middleton, Michael S
2015-10-01
To assess feasibility of and agreement between magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS) for estimating hepatic proton density fat fraction (PDFF) in children with known or suspected nonalcoholic fatty liver disease (NAFLD). Children were included in this study from two previous research studies in each of which three MRI and three MRS acquisitions were obtained. Sequence acceptability, and MRI- and MRS-estimated PDFF were evaluated. Agreement of MRI- with MRS-estimated hepatic PDFF was assessed by linear regression and Bland-Altman analysis. Age, sex, BMI-Z score, acquisition time, and artifact score effects on MRI- and MRS-estimated PDFF agreement were assessed by multiple linear regression. Eighty-six children (61 boys and 25 girls) were included in this study. Slope and intercept from regressing MRS-PDFF on MRI-PDFF were 0.969 and 1.591%, respectively, and the Bland-Altman bias and 95% limits of agreement were 1.17% ± 2.61%. MRI motion artifact score was higher in boys than girls (by 0.21, p = 0.021). Higher BMI-Z score was associated with lower agreement between MRS and MRI (p = 0.045). Hepatic PDFF estimation by both MRI and MRS is feasible, and MRI- and MRS-estimated PDFF agree closely in children with known or suspected NAFLD.
Multivoxel MR Spectroscopy in Acute Ischemic Stroke:Comparison to the Stroke Protocol MRI
Dani, Krishna A.; An, Li; Henning, Erica C.; Shen, Jun; Warach, Steven
2014-01-01
Background and Purpose Few patients with stroke have been imaged with MR spectroscopy (MRS) within the first few hours after onset. We compared data from current MRI protocols to MRS in subjects with ischemic stroke. Methods MRS was incorporated into the standard clinical MRI stroke protocol for subjects <24 hours after onset. MRI and clinical correlates for the metabolic data from MRS were sought. Results One hundred thirty-six MRS voxels from 32 subjects were analyzed. Lactate preceded the appearance of the lesion on diffusion-weighted imaging in some voxels but in others lagged behind it. Current protocols may predict up to 41% of the variance of MRS metabolites. Serum glucose concentration and time to maximum partially predicted the concentration of all major metabolites. Conclusion MRS may be helpful in acute stroke, especially for lactate detection when perfusion-weighted imaging is unavailable. Current MRI protocols do provide surrogate markers for some indices of metabolic activity. PMID:23091121
Parto Dezfouli, Mohammad Ali; Dezfouli, Mohsen Parto; Rad, Hamidreza Saligheh
2014-01-01
Proton magnetic resonance spectroscopy ((1)H-MRS) is a non-invasive diagnostic tool for measuring biochemical changes in the human body. Acquired (1)H-MRS signals may be corrupted due to a wideband baseline signal generated by macromolecules. Recently, several methods have been developed for the correction of such baseline signals, however most of them are not able to estimate baseline in complex overlapped signal. In this study, a novel automatic baseline correction method is proposed for (1)H-MRS spectra based on ensemble empirical mode decomposition (EEMD). This investigation was applied on both the simulated data and the in-vivo (1)H-MRS of human brain signals. Results justify the efficiency of the proposed method to remove the baseline from (1)H-MRS signals.
1H-MRSI applied to study Huntington's disease
NASA Astrophysics Data System (ADS)
Rodríguez, A. O.
2000-10-01
In vivo Magnetic Resonance Spectrocopy (MRS) was applied to study Huntington's disease. Two solvent-suppressed and single-voxel MRS methods were used: PRESS and STEAM. We applied these popular MRS sequences to Huntington's disease patients (HD) and healthy volunteers (HV). We also compared our spectra between HD and HV as well the these two modalities. Spectra results are reported for HD and HV for both MRS schemes.
Banks, Jamie L; Marotta, Charles A
2007-03-01
The modified Rankin scale (mRS), a clinician-reported measure of global disability, is widely applied for evaluating stroke patient outcomes and as an end point in randomized clinical trials. Extensive evidence on the validity of the mRS exists across a large but fragmented literature. As new treatments for acute ischemic stroke are submitted for agency approval, an appreciation of the mRS's attributes, specifically its relationship to other stroke evaluation scales, would be valuable for decision-makers to properly assess the impact of a new drug on treatment paradigms. The purpose of this report is to assemble and systematically assess the properties of the mRS to provide decision-makers with pertinent evaluative information. A Medline search was conducted to identify reports in the peer-reviewed medical literature (1957-2006) that provide information on the structure, validation, scoring, and psychometric properties of the mRS and its use in clinical trials. The selection of articles was based on defined criteria that included relevance, study design and use of appropriate statistical methods. Of 224 articles identified by the literature search, 50 were selected for detailed assessment. Inter-rater reliability with the mRS is moderate and improves with structured interviews (kappa 0.56 versus 0.78); strong test-re-test reliability (kappa=0.81 to 0.95) has been reported. Numerous studies demonstrate the construct validity of the mRS by its relationships to physiological indicators such as stroke type, lesion size, perfusion and neurological impairment. Convergent validity between the mRS and other disability scales is well documented. Patient comorbidities and socioeconomic factors should be considered in properly applying and interpreting the mRS. Recent analyses suggest that randomized clinical trials of acute stroke treatments may require a smaller sample size if the mRS is used as a primary end point rather than the Barthel Index. Multiple types of evidence attest to the validity and reliability of the mRS. The reported data support the view that the mRS is a valuable instrument for assessing the impact of new stroke treatments.
Uhl, Mirella Carolin; Muth, Christiane; Gerlach, Ferdinand Michael; Schoch, Goentje-Gesine; Müller, Beate Sigrid
2018-01-05
Although polypharmacy can cause adverse health outcomes, patients often know little about their medication. A regularly conducted medication review (MR) can help provide an overview of a patient's medication, and benefit patients by enhancing their knowledge of their drugs. As little is known about patient attitudes towards MRs in primary care, the objective of this study was to gain insight into patient-perceived barriers and facilitators to the implementation of an MR. We conducted a qualitative study with a convenience sample of 31 patients (age ≥ 60 years, ≥3 chronic diseases, taking ≥5 drugs/d); in Hesse, Germany, in February 2016. We conducted two focus groups and, in order to ensure the participation of elderly patients with reduced mobility, 16 telephone interviews. Both relied on a semi-structured interview guide dealing with the following subjects: patients' experience of polypharmacy, general design of MRs, potential barriers and facilitators to implementation etc. Interviews were audio-recorded, transcribed verbatim, and analysed by two researchers using thematic analysis. Patients' average age was 74 years (range 62-88 years). We identified barriers and facilitators for four main topics regarding the implementation of MRs in primary care: patient participation, GP-led MRs, pharmacist-led MRs, and the involvement of healthcare assistants in MRs. Barriers to patient participation concerned patient autonomy, while facilitators involved patient awareness of medication-related problems. Barriers to GP-led MRs concerned GP's lack of resources while facilitators related to the trusting relationship between patient and GP. Pharmacist-led MRs might be hindered by a lack of patients' confidence in pharmacists' expertise, but facilitated by pharmacies' digital records of the patients' medications. Regarding the involvement of healthcare assistants in MRs, a potential barrier was patients' uncertainty regarding the extent of their training. Patients could, however, imagine GPs delegating some aspects of MRs to them. Our study suggests that patients regard MRs as beneficial and expect indications for their medicines to be checked, and possible interactions to be identified. To foster the implementation of MRs in primary care, it is important to consider barriers and facilitators to the four identified topics.
Measuring Glial Metabolism in Repetitive Brain Trauma and Alzheimer’s Disease
2016-09-01
Six methods: Single value decomposition (SVD), wavelet, sliding window, sliding window with Gaussian weighting, spline and spectral improvements...comparison of a range of different denoising methods for dynamic MRS. Six denoising methods were considered: Single value decomposition (SVD), wavelet...project by improving the software required for the data analysis by developing six different denoising methods. He also assisted with the testing
Identification of Microbial Gene Biomarkers for in situ RDX Biodegradation
2012-12-01
Additional research is required to determine reliable guidelines to inform site managers of specific field concentrations of ammonium and nitrate...Mrs. Cynthia L. Price, Research Biologist, EPED, EL, ERDC; Dr. Rick Arnseth, Project Manager / Geochemist, Tetra Tech Inc., Oak Ridge, TN; and...a biomarker of RDX degradation, as it will also be necessary for bioremediation site managers to measure soil and groundwater concentra- tions for
Hussain, Tahir; Yogavel, Manickam; Sharma, Amit
2015-04-01
Aminoacyl-tRNA synthetases (aaRSs) are housekeeping enzymes that couple cognate tRNAs with amino acids to transmit genomic information for protein translation. The Plasmodium falciparum nuclear genome encodes two P. falciparum methionyl-tRNA synthetases (PfMRS), termed PfMRS(cyt) and PfMRS(api). Phylogenetic analyses revealed that the two proteins are of primitive origin and are related to heterokonts (PfMRS(cyt)) or proteobacteria/primitive bacteria (PfMRS(api)). We show that PfMRS(cyt) localizes in parasite cytoplasm, while PfMRS(api) localizes to apicoplasts in asexual stages of malaria parasites. Two known bacterial MRS inhibitors, REP3123 and REP8839, hampered Plasmodium growth very effectively in the early and late stages of parasite development. Small-molecule drug-like libraries were screened against modeled PfMRS structures, and several "hit" compounds showed significant effects on parasite growth. We then tested the effects of the hit compounds on protein translation by labeling nascent proteins with (35)S-labeled cysteine and methionine. Three of the tested compounds reduced protein synthesis and also blocked parasite growth progression from the ring stage to the trophozoite stage. Drug docking studies suggested distinct modes of binding for the three compounds, compared with the enzyme product methionyl adenylate. Therefore, this study provides new targets (PfMRSs) and hit compounds that can be explored for development as antimalarial drugs. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Mühlenhoff, Ulrich; Stadler, Jochen A; Richhardt, Nadine; Seubert, Andreas; Eickhorst, Thomas; Schweyen, Rudolf J; Lill, Roland; Wiesenberger, Gerlinde
2003-10-17
The yeast genes MRS3 and MRS4 encode two members of the mitochondrial carrier family with high sequence similarity. To elucidate their function we utilized genome-wide expression profiling and found that both deletion and overexpression of MRS3/4 lead to up-regulation of several genes of the "iron regulon." We therefore analyzed the two major iron-utilizing processes, heme formation and Fe/S protein biosynthesis in vivo, in organello (intact mitochondria), and in vitro (mitochondrial extracts). Radiolabeling of yeast cells with 55Fe revealed a clear correlation between MRS3/4 expression levels and the efficiency of these biosynthetic reactions indicating a role of the carriers in utilization and/or transport of iron in vivo. Similar effects on both heme formation and Fe/S protein biosynthesis were seen in organello using mitochondria isolated from cells grown under iron-limiting conditions. The correlation between MRS3/4 expression levels and the efficiency of the two iron-utilizing processes was lost upon detergent lysis of mitochondria. As no significant changes in the mitochondrial membrane potential were observed upon overexpression or deletion of MRS3/4, our results suggest that Mrs3/4p carriers are directly involved in mitochondrial iron uptake. Mrs3/4p function in mitochondrial iron transport becomes evident under iron-limiting conditions only, indicating that the two carriers do not represent the sole system for mitochondrial iron acquisition.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gatu Johnson, M., E-mail: gatu@psfc.mit.edu; Frenje, J. A.; Li, C. K.
2016-11-15
The Magnetic Recoil neutron Spectrometer (MRS) on the National Ignition Facility measures the DT neutron spectrum from cryogenically layered inertial confinement fusion implosions. Yield, areal density, apparent ion temperature, and directional fluid flow are inferred from the MRS data. This paper describes recent advances in MRS measurements of the primary peak using new, thinner, reduced-area deuterated plastic (CD) conversion foils. The new foils allow operation of MRS at yields 2 orders of magnitude higher than previously possible, at a resolution down to ∼200 keV FWHM.
Gatu Johnson, M.; Frenje, J. A.; Bionta, R. M.; ...
2016-08-09
The Magnetic Recoil neutron Spectrometer (MRS) on the National Ignition Facility measures the DT neutron spectrum from cryogenically layered inertial confinement fusion implosions. Yield, areal density, apparent ion temperature, and directional fluid flow are inferred from the MRS data. Here, this paper describes recent advances in MRS measurements of the primary peak using new, thinner, reduced-area deuterated plastic (CD) conversion foils. The new foils allow operation of MRS at yields 2 orders of magnitude higher than previously possible, at a resolution down to ~200 keV FWHM.
Gatu Johnson, M; Frenje, J A; Bionta, R M; Casey, D T; Eckart, M J; Farrell, M P; Grim, G P; Hartouni, E P; Hatarik, R; Hoppe, M; Kilkenny, J D; Li, C K; Petrasso, R D; Reynolds, H G; Sayre, D B; Schoff, M E; Séguin, F H; Skulina, K; Yeamans, C B
2016-11-01
The Magnetic Recoil neutron Spectrometer (MRS) on the National Ignition Facility measures the DT neutron spectrum from cryogenically layered inertial confinement fusion implosions. Yield, areal density, apparent ion temperature, and directional fluid flow are inferred from the MRS data. This paper describes recent advances in MRS measurements of the primary peak using new, thinner, reduced-area deuterated plastic (CD) conversion foils. The new foils allow operation of MRS at yields 2 orders of magnitude higher than previously possible, at a resolution down to ∼200 keV FWHM.
Physical activity, stress, and metabolic risk score in 8- to 18-year-old boys.
Holmes, Megan E; Eisenmann, Joey C; Ekkekakis, Panteleimon; Gentile, Douglas
2008-03-01
We examined whether physical activity modifies the relationship between stress and the metabolic risk score in 8- to 18-year-old males (n = 37). Physical activity (PA) and television (TV)/videogame (VG) use were assessed via accelerometer and questionnaire, respectively. Stress was determined from self-report measures. A metabolic risk score (MRS) was created by summing age-standardized residuals for waist circumference, mean arterial pressure, glycosylated hemoglobin, and high-density lipoprotein cholesterol. Correlations between PA and MRS were low (r < -.13), and TV and VG were moderately associated with MRS (r = .39 and .43, respectively). Correlations between stress-related variables and MRS ranged from r = .19 to .64. After partitioning by PA, significant correlations were observed in the low PA group between school- and sports-related self-esteem and anxiety with the MRS. The results provide suggestive evidence that PA might modify the relationship between stress and MRS in male adolescents.
Ultra-High-Field Magnetic Resonance Spectroscopy in Psychiatry.
Godlewska, Beata R; Clare, Stuart; Cowen, Philip J; Emir, Uzay E
2017-01-01
The advantages of ultra-high-field (UHF ≥ 7T) MR have been demonstrated in a variety of MR acquisition modalities. Magnetic resonance spectroscopy (MRS) can particularly benefit from substantial gains in signal-to-noise ratio (SNR) and spectral resolution at UHF, enabling the quantification of numerous metabolites, including glutamate, glutamine, glutathione, and γ-aminobutyric acid that are relevant to psychiatric disorders. The aim of this review is to give an overview about the advantages and advances of UHF MRS and its application to psychiatric disorders. In order to provide a practical guide for potential applications of MRS at UHF, a literature review is given, surveying advantages and disadvantages of MRS at UHF. Key concepts, emerging technologies, practical considerations, and applications of UHF MRS are provided. Second, the strength of UHF MRS is demonstrated using some examples of its application in psychiatric disorders.
Ultra-High-Field Magnetic Resonance Spectroscopy in Psychiatry
Godlewska, Beata R.; Clare, Stuart; Cowen, Philip J.; Emir, Uzay E.
2017-01-01
The advantages of ultra-high-field (UHF ≥ 7T) MR have been demonstrated in a variety of MR acquisition modalities. Magnetic resonance spectroscopy (MRS) can particularly benefit from substantial gains in signal-to-noise ratio (SNR) and spectral resolution at UHF, enabling the quantification of numerous metabolites, including glutamate, glutamine, glutathione, and γ-aminobutyric acid that are relevant to psychiatric disorders. The aim of this review is to give an overview about the advantages and advances of UHF MRS and its application to psychiatric disorders. In order to provide a practical guide for potential applications of MRS at UHF, a literature review is given, surveying advantages and disadvantages of MRS at UHF. Key concepts, emerging technologies, practical considerations, and applications of UHF MRS are provided. Second, the strength of UHF MRS is demonstrated using some examples of its application in psychiatric disorders. PMID:28744229
mrsFAST-Ultra: a compact, SNP-aware mapper for high performance sequencing applications.
Hach, Faraz; Sarrafi, Iman; Hormozdiari, Farhad; Alkan, Can; Eichler, Evan E; Sahinalp, S Cenk
2014-07-01
High throughput sequencing (HTS) platforms generate unprecedented amounts of data that introduce challenges for processing and downstream analysis. While tools that report the 'best' mapping location of each read provide a fast way to process HTS data, they are not suitable for many types of downstream analysis such as structural variation detection, where it is important to report multiple mapping loci for each read. For this purpose we introduce mrsFAST-Ultra, a fast, cache oblivious, SNP-aware aligner that can handle the multi-mapping of HTS reads very efficiently. mrsFAST-Ultra improves mrsFAST, our first cache oblivious read aligner capable of handling multi-mapping reads, through new and compact index structures that reduce not only the overall memory usage but also the number of CPU operations per alignment. In fact the size of the index generated by mrsFAST-Ultra is 10 times smaller than that of mrsFAST. As importantly, mrsFAST-Ultra introduces new features such as being able to (i) obtain the best mapping loci for each read, and (ii) return all reads that have at most n mapping loci (within an error threshold), together with these loci, for any user specified n. Furthermore, mrsFAST-Ultra is SNP-aware, i.e. it can map reads to reference genome while discounting the mismatches that occur at common SNP locations provided by db-SNP; this significantly increases the number of reads that can be mapped to the reference genome. Notice that all of the above features are implemented within the index structure and are not simple post-processing steps and thus are performed highly efficiently. Finally, mrsFAST-Ultra utilizes multiple available cores and processors and can be tuned for various memory settings. Our results show that mrsFAST-Ultra is roughly five times faster than its predecessor mrsFAST. In comparison to newly enhanced popular tools such as Bowtie2, it is more sensitive (it can report 10 times or more mappings per read) and much faster (six times or more) in the multi-mapping mode. Furthermore, mrsFAST-Ultra has an index size of 2GB for the entire human reference genome, which is roughly half of that of Bowtie2. mrsFAST-Ultra is open source and it can be accessed at http://mrsfast.sourceforge.net. © The Author(s) 2014. Published by Oxford University Press on behalf of Nucleic Acids Research.
ERIC Educational Resources Information Center
Corey, Jennifer M.; German, Kathleen M.
Corazon Aquino's appearance before the U.S. Congress provides an opportunity for the rhetorical critic to study (1) how the form of speech--particularly the romantic form--enabled Aquino to establish the legitimacy of her claims as President of the Philippines; (2) how she used her role as Benigno Aquino's widow to complete the romantic myth; and…
Influenza vaccination coverage among medical residents: an Italian multicenter survey.
Costantino, Claudio; Mazzucco, Walter; Azzolini, Elena; Baldini, Cesare; Bergomi, Margherita; Biafiore, Alessio Daniele; Bianco, Manuela; Borsari, Lucia; Cacciari, Paolo; Cadeddu, Chiara; Camia, Paola; Carluccio, Eugenia; Conti, Andrea; De Waure, Chiara; Di Gregori, Valentina; Fabiani, Leila; Fallico, Roberto; Filisetti, Barbara; Flacco, Maria E; Franco, Elisabetta; Furnari, Roberto; Galis, Veronica; Gallea, Maria R; Gallone, Maria F; Gallone, Serena; Gelatti, Umberto; Gilardi, Francesco; Giuliani, Anna R; Grillo, Orazio C; Lanati, Niccolò; Mascaretti, Silvia; Mattei, Antonella; Micò, Rocco; Morciano, Laura; Nante, Nicola; Napoli, Giuseppe; Nobile, Carmelo Giuseppe; Palladino, Raffaele; Parisi, Salvatore; Passaro, Maria; Pelissero, Gabriele; Quarto, Michele; Ricciardi, Walter; Romano, Gabriele; Rustico, Ennio; Saponari, Anita; Schioppa, Francesco S; Signorelli, Carlo; Siliquini, Roberta; Trabacchi, Valeria; Triassi, Maria; Varetta, Alessia; Ziglio, Andrea; Zoccali, Angela; Vitale, Francesco; Amodio, Emanuele
2014-01-01
Although influenza vaccination is recognized to be safe and effective, recent studies have confirmed that immunization coverage among health care workers remain generally low, especially among medical residents (MRs). Aim of the present multicenter study was to investigate attitudes and determinants associated with acceptance of influenza vaccination among Italian MRs. A survey was performed in 2012 on MRs attending post-graduate schools of 18 Italian Universities. Each participant was interviewed via an anonymous, self-administered, web-based questionnaire including questions on attitudes regarding influenza vaccination. A total of 2506 MRs were recruited in the survey and 299 (11.9%) of these stated they had accepted influenza vaccination in 2011-2012 season. Vaccinated MRs were older (P = 0.006), working in clinical settings (P = 0.048), and vaccinated in the 2 previous seasons (P<0.001 in both seasons). Moreover, MRs who had recommended influenza vaccination to their patients were significantly more compliant with influenza vaccination uptake in 2011-2012 season (P<0.001). "To avoid spreading influenza among patients" was recognized as the main reason for accepting vaccination by less than 15% of vaccinated MRs. Italian MRs seem to have a very low compliance with influenza vaccination and they seem to accept influenza vaccination as a habit that is unrelated to professional and ethical responsibility. Otherwise, residents who refuse vaccination in the previous seasons usually maintain their behaviors. Promoting correct attitudes and good practice in order to improve the influenza immunization rates of MRs could represent a decisive goal for increasing immunization coverage among health care workers of the future.
Development of FARICH detector for particle identification system at accelerators
NASA Astrophysics Data System (ADS)
Finogeev, D. A.; Kurepin, A. B.; Razin, V. I.; Reshetin, A. I.; Usenko, E. A.; Barnyakov, A. Yu.; Barnyakov, M. Yu.; Bobrovnikov, V. S.; Buzykaev, A. R.; Kasyanenko, P. V.; Kononov, S. A.; Kravchenko, E. A.; Kuyanov, I. A.; Onuchin, A. P.; Ovtin, I. V.; Podgornov, N. A.; Talyshev, A. A.; Danilyuk, A. F.
2018-01-01
Aerogel has been successfully used as a radiator in Cherenkov detectors. In 2004, a multilayer aerogel providing Cherenkov ring focusing was proposed and produced. FARICH (Focusing Aerogel Rich Imaging CHerenkov) detectors such as ARICH for Belle-II (KEK, Japan), Forward RICH for PANDA detector (FAIR, Germany), and FARICH for the Super Charm-Tau factory project (BINP, Novosibirsk) have been developed based on this aerogel. Prototypes of FARICH detector based on MRS APD and Philips DPC photosensors were developed and tested in the framework of this project. An angular resolution for Cherenkov rings of 3.6 mrad was achieved.
Proton magnetic resonance spectroscopy of tubercular breast abscess: report of a case.
Das, Chandan Jyoti; Medhi, Kunjahari
2008-01-01
In vivo proton magnetic resonance spectroscopy (H-MRS) is a functional imaging modality. When magnetic resonance imaging is coupled with H-MRS, it results in accurate metabolic characterization of various lesions. Proton magnetic resonance spectroscopy has an established role in evaluating malignant breast lesions, and the increasing number of published literature supports the role of H-MRS in patients with breast cancer. However, H-MRS can be of help in evaluating benign breast disease. We present a case of tubercular breast abscess, initial diagnosis of which was suggested based on characteristic lipid pick on H-MRS and was subsequently confirmed by fine needle aspiration biopsy of the breast lesion.
NASA Astrophysics Data System (ADS)
Vouillamoz, J. M.; Lawson, F. M. A.; Yalo, N.; Descloitres, M.
2014-08-01
Hundreds of thousands of boreholes have been drilled in hard rocks of Africa and Asia for supplying human communities with drinking water. Despite the common use of geophysics for improving the siting of boreholes, a significant number of drilled holes does not deliver enough water to be equipped (e.g. 40% on average in Benin). As compared to other non-invasive geophysical methods, magnetic resonance sounding (MRS) is selective to groundwater. However, this distinctive feature has not been fully used in previous published studies for quantifying the drainable groundwater in hard rocks (i.e. the specific yield) and the short-term productivity of aquifer (i.e. the transmissivity). We present in this paper a comparison of MRS results (i.e. the water content and pore-size parameter) with both specific yield and transmissivity calculated from long duration pumping tests. We conducted our experiments in six sites located in different hard rock groups in Benin, thus providing a unique data set to assess the usefulness of MRS in hard rock aquifers. We found that the MRS water content is about twice the specific yield. We also found that the MRS pore-size parameter is well correlated with the specific yield. Thus we proposed two linear equations for calculating the specific yield from the MRS water content (with an uncertainty of about 10%) and from the pore-size parameter (with an uncertainty of about 20%). The later has the advantage of defining a so-named MRS cutoff time value for indentifying non-drainable MRS water content and thus low groundwater reserve. We eventually propose a nonlinear equation for calculating the specific yield using jointly the MRS water content and the pore-size parameters, but this approach has to be confirmed with further investigations. This study also confirmed that aquifer transmissivity can be estimated from MRS results with an uncertainty of about 70%. We conclude that MRS can be usefully applied for estimating aquifer specific yield and transmissivity in weathered hard rock aquifers. Our result will contribute to the improvement of well siting and groundwater management in hard rocks.
Ringh, Mattias; Fredman, David; Nordberg, Per; Stark, Tomas; Hollenberg, Jacob
2011-12-01
In a two-parted study, evaluate a new concept were mobile phone technology is used to dispatch lay responders to nearby out-of-hospital cardiac arrests (OHCAs). Mobile phone positioning systems (MPS) can geographically locate selected mobile phone users at any given moment. A mobile phone service using MPS was developed and named Mobile Life Saver (MLS). Simulation study: 25 volunteers named mobile responders (MRs) were connected to MLS. Ambulance time intervals from 22 consecutive OHCAs in 2005 were used as controls. The MRs randomly moved in Stockholm city centre and were dispatched to simulated OHCAs (identical to controls) if they were within a 350 m distance. Real life study: during 25 weeks 1271-1801 MRs trained in CPR were connected to MLS. MLS was activated at the dispatch centre in parallel with ambulance dispatch when an OHCA was suspected. The MRs were dispatched if they were within 500 m from the suspected OHCA. Simulation study: mean response time for the MRs compared to historical ambulance time intervals was reduced by 2 min 20s (44%), p<0.001, (95% CI, 1 min 5s - 3 min 35s). The MRs reached the simulated OHCA prior to the historical control in 72% of cases. Real life study: the MLS was triggered 92 times. In 45% of all suspected and in 56% of all true OHCAs the MRs arrived prior to ambulance. CPR was performed by MRs in 17% of all true OHCAs and in 30% of all true OHCAs if MRs arrived prior to ambulance. Mobile phone technology can be used to identify and recruit nearby CPR-trained citizens to OHCAs for bystander CPR prior to ambulance arrival. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Min, Yang Won; Shin, Inseub; Son, Hee Jung; Rhee, Poong-Lyul
2015-01-01
Abstract The clinical significance of ineffective esophageal motility (IEM) together with multiple rapid swallow (MRS) has not been yet evaluated in the Chicago Classification v3.0. This study evaluated the adjunctive role of MRS in IEM and determined the criteria of abnormal MRS to maximize the utility of IEM. We analyzed 186 patients showing IEM or normal esophageal motility (NEM), who underwent esophageal high-resolution impedance–manometry for esophageal symptoms. Two different criteria for abnormal MRS were applied to IEM subjects, resulting in 2 corresponding subgroups: IEM-A when distal contractile integral (DCI) ratio between an average wet swallows and MRS contraction was <1 and IEM-B when MRS contraction DCI was <450 mm Hg-s-cm. One IEM subject inadequately performed MRS. Among the remaining 52 IEM subjects, 18 (34.6%) were classified into IEM-A and 23 (44.2%) into IEM-B. IEM subjects showed less complete bolus transit (median 0.0%, interquartile range 0.0–20.0% vs 60.0%, 30.0–80.0; P < 0.001) resulting in higher impaired bolus transit than NEM subjects (98.1% vs 66.9%, P = 0.001). IEM-B subjects showed additionally higher pathologic bolus exposure than NEM subjects (55.6% vs 29.3%, P = 0.001), whereas IEM-A subjects could not. Although IEM-B subjects had the highest prevalence of gastroesophageal reflux disease among the subjects groups, it did not reach statistical significance. In conclusion, IEM patients with abnormal MRS contraction have an increased risk of prolonged bolus clearance, poor bolus transit, and pathologic bolus exposure. IEM patients need to be assessed concerning whether MRS contraction DCI is <450 mm Hg-s-cm to segregate clinically relevant patients. PMID:26448010
Added Value of Patient-Reported Outcome Measures in Stroke Clinical Practice.
Katzan, Irene L; Thompson, Nicolas R; Lapin, Brittany; Uchino, Ken
2017-07-21
There is uncertainty regarding the clinical utility of the data obtained from patient-reported outcome measures (PROMs) for patient care. We evaluated the incremental information obtained by PROMs compared to the clinician-reported modified Rankin Scale (mRS). This was an observational study of 3283 ischemic stroke patients seen in a cerebrovascular clinic from September 14, 2012 to June 16, 2015 who completed the routinely collected PROMs: Stroke Impact Scale-16 (SIS-16), EQ-5D, Patient Health Questionnaire-9, PROMIS Physical Function, and PROMIS fatigue. The amount of variation in the PROMs explained by mRS was determined using r 2 after adjustment for age and level of stroke impairment. The proportion with meaningful change was calculated for patients with ≥2 visits. Concordance with change in the other scales and the ability to discriminate changes in health state as measured by c-statistic was evaluated for mRS versus SIS-16. Correlation between PROMs and mRS was highest for SIS-16 ( r =-0.64, P <0.01). The r 2 ranged from 0.11 (PROMIS fatigue) to 0.56 (SIS-16). Change in scores occurred in 51% with mRS and 35% with SIS-16. There was lower agreement and less ability to discriminate change in mRS than in SIS-16 with change in the other measures. PROMs provide additional valuable information compared to the mRS alone in stroke patients seen in the ambulatory setting. SIS-16 may have a better ability to identify change than mRS in health status of relevance to the patient. PROMs may be a useful addition to mRS in the assessment of health status in clinical practice. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Shaker, Anisa; Stoikes, Nathaniel; Drapekin, Jesse; Kushnir, Vladimir; Brunt, L. Michael; Gyawali, C. Prakash
2014-01-01
OBJECTIVES Dysphagia may develop following antireflux surgery as a consequence of poor esophageal peristaltic reserve. We hypothesized that suboptimal contraction response following multiple rapid swallows (MRS) could be associated with chronic transit symptoms following antireflux surgery. METHODS Wet swallow and MRS responses on esophageal high-resolution manometry (HRM) were characterized collectively in the esophageal body (distal contractile integral (DCI)), and individually in each smooth muscle contraction segment (S2 and S3 amplitudes) in 63 patients undergoing antireflux surgery and in 18 healthy controls. Dysphagia was assessed using symptom questionnaires. The MRS/wet swallow ratios were calculated for S2 and S3 peak amplitudes and DCI. MRS responses were compared in patients with and without late postoperative dysphagia following antireflux surgery. RESULTS Augmentation of smooth muscle contraction (MRS/wet swallow ratios > 1.0) as measured collectively by DCI was seen in only 11.1% with late postoperative dysphagia, compared with 63.6% in those with no dysphagia and 78.1% in controls (P≤0.02 for each comparison). Similar results were seen with S3 but not S2 peak amplitude ratios. Receiver operating characteristics identified a DCI MRS/wet swallow ratio threshold of 0.85 in segregating patients with late postoperative dysphagia from those with no postoperative dysphagia with a sensitivity of 0.67 and specificity of 0.64. CONCLUSIONS Lack of augmentation of smooth muscle contraction following MRS is associated with late postoperative dysphagia following antireflux surgery, suggesting that MRS responses could assess esophageal smooth muscle peristaltic reserve. Further research is warranted to determine if antireflux surgery needs to be tailored to the MRS response. PMID:24019081
Minimalist Running Shoes and Injury Risk Among United States Army Soldiers.
Grier, Tyson; Canham-Chervak, Michelle; Bushman, Timothy; Anderson, Morgan; North, William; Jones, Bruce H
2016-06-01
Minimalist running shoes (MRS) are lightweight, are extremely flexible, and have little to no cushioning. It has been thought that MRS will enhance running performance and decrease injury risk. To compare physical characteristics, fitness performance, and injury risks associated with soldiers wearing MRS and those wearing traditional running shoes (TRS). Case series; Level of evidence, 4. Participants were men in a United States Army brigade (N = 1332). Physical characteristics and Army Physical Fitness Test data were obtained by survey. Fitness performance testing was administered at the brigade, and the types of footwear worn were identified by visual inspection. Shoe types were categorized into 2 groups: TRS (stability, cushioning, and motion control) and MRS. Injuries from the previous 12 months were obtained from the Defense Medical Surveillance System. A t test was used to determine mean differences between personal characteristics, training, and fitness performance metrics by shoe type. Hazard ratios and 95% CIs were calculated to determine injury risk by shoe type, controlling for other risk factors. A majority of soldiers wore cushioning shoes (57%), followed by stability shoes (24%), MRS (17%), and motion control shoes (2%). Soldiers wearing MRS were slightly younger than those wearing TRS (P < .01); performed more push-ups, sit-ups, and pull-ups (P < .01); and ran faster during the 2-mile run (P = .01). When other risk factors were controlled, there was no difference in injury risk for running shoe type between soldiers wearing MRS compared with TRS. Soldiers who chose to wear MRS were younger and had higher physical performance scores compared with soldiers wearing TRS. When these differences are controlled, use of MRS does not appear to be associated with higher or lower injury risk in this population. © 2016 The Author(s).
A Constrained Genetic Algorithm with Adaptively Defined Fitness Function in MRS Quantification
NASA Astrophysics Data System (ADS)
Papakostas, G. A.; Karras, D. A.; Mertzios, B. G.; Graveron-Demilly, D.; van Ormondt, D.
MRS Signal quantification is a rather involved procedure and has attracted the interest of the medical engineering community, regarding the development of computationally efficient methodologies. Significant contributions based on Computational Intelligence tools, such as Neural Networks (NNs), demonstrated a good performance but not without drawbacks already discussed by the authors. On the other hand preliminary application of Genetic Algorithms (GA) has already been reported in the literature by the authors regarding the peak detection problem encountered in MRS quantification using the Voigt line shape model. This paper investigates a novel constrained genetic algorithm involving a generic and adaptively defined fitness function which extends the simple genetic algorithm methodology in case of noisy signals. The applicability of this new algorithm is scrutinized through experimentation in artificial MRS signals interleaved with noise, regarding its signal fitting capabilities. Although extensive experiments with real world MRS signals are necessary, the herein shown performance illustrates the method's potential to be established as a generic MRS metabolites quantification procedure.
Rahman, M Hafizur; Agarwal, Smisha; Tuddenham, Susan; Peto, Heather; Iqbal, Mohammad; Bhuiya, Abbas; Peters, David H
2015-07-01
Informally trained village doctors supply the majority of healthcare services to the rural poor in many developing countries. This study describes the demographic and socio-economic differences between medical representatives (MRs) and village doctors in rural Bangladesh, and explores the nature of their interactions. This study was conducted in Chakaria, a rural sub-district of Bangladesh. Focus group discussions and in-depth interviews were conducted, along with a quantitative survey to understand practice perceptions. Data analysis was performed using grounded theory and bivariate statistical tests. We surveyed 43 MRs and 83 village doctors through 22 focus group discussions and 33 in-depth interviews. MRs have a higher average per capita monthly expenditure compared to village doctors. MRs are better educated with 98% having bachelor's degrees whereas 84% of village doctors have twelfth grade education or less (p<0.001). MRs are the principal information source about new medications for the village doctors. Furthermore, incentives offered by MRs and credit availability influence the prescription practices of village doctors. MRs being the key player in providing information about drugs to village doctors might influence their prescription practices. Improvements in the quality of healthcare delivered to the rural poor in informal provider-based health markets require stricter regulations and educational initiatives for providers and MRs. © The Author 2014. Published by Oxford University Press on behalf of Royal Society of Tropical Medicine and Hygiene. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Advance Planning Briefing for Industry: Sustaining the Warfighter through Battlespace Integration
1998-05-14
value, Indefinite Delivery/Indefinite Quantity procurement, and consist of a base year and 4 option years. BRIEFER: COL Alfred J. Estrella ...Indefinite Delivery/Indefinite Quantity procurement, and consist of a base year plus 4 option years. BRIEFER: COL Alfred J. Estrella , Commander, US...MR. ROBERT R. LEHNES DPEO, C3S MR. DENNIS TURNER DIR, CECOM SEC COL ALFRED J. ESTRELLA COMMANDER, ISEC MRS. MAUREEN MACFARLAND DEP DIR, CECOM
2016-10-30
created educational materials to provide more information about specific topics of interest, such as minimalist running shoes and extreme conditioning...to communicate risks, dispel myths, and provide more information about specific topics of interest. A Minimalist Running Shoe (MRS) brochure and...M, North W, Jones BH. 2016. Minimalist Running Shoes and Injury Risk among U.S. Army Soldiers. American Journal of Sports Medicine, 44(6): 1439
Roffman, J L; Lipska, B K; Bertolino, A; Van Gelderen, P; Olson, A W; Khaing, Z Z; Weinberger, D R
2000-04-01
The rat medial prefrontal cortex (mPFC) regulates subcortical dopamine transmission via projections to the striatum and ventral tegmental area. We used in vivo proton magnetic resonance spectroscopy (1H-MRS) at 4.7 T to determine whether excitotoxic lesions of the mPFC result in alterations of N-acetylaspartate (NAA), a marker of neuronal integrity, both locally and downstream in the striatum. Lesioned rats exhibited persistent reductions of NAA and other metabolites within the prefrontal cortex; selective reductions of NAA were seen in the striatum, but not in the parietal cortex. Consistent with earlier reports, lesioned rats exhibited a transient enhancement in amphetamine-induced hyperlocomotion. Prefrontal NAA losses correlated with lesion extent. In the striatum, while there was no change in tissue volume, expression of striatal glutamic acid decarboxylase-67 mRNA was significantly reduced. In vivo NAA levels thus appear sensitive to both local and downstream alterations in neuronal integrity, and may signal meaningful effects at cellular and behavioral levels.
MOCR activity during Day 6 of STS-3 mission
NASA Technical Reports Server (NTRS)
1982-01-01
Andrew A. Fullerton, the six-year-old son of STS-3 pilot C. Gordon Fullerton, watches a television monitor in the mission control center's viewing room (28802); Mrs. Marie J. Fullerton in the mission control center's viewing room. Other members of the STS-3 pilot's family are seated on each side of Mrs. Fullerton. His sister, Jeanne Dockham, is at left foreground; son Andrew A., at right foreground. Mr. and Mrs. E. G. Buettner, Mrs. Fullerton's parents, are seated at center, and beyond them is Mrs. Charles R. Fullerton, the astronaut's mother (28803); Mary Ann Austin seated at the remote manipulator sytem (RMS) console in the mission operations control room (MOCR) shares the scene with a representation of a 1/15-scale model of the Canadian-built remote manipulator system arm (28804).
Oriol, Albert; Valverde, Daniel; Capellades, Jaume; Cabañas, Miquel E; Ribera, Josep-Maria; Arús, Carles
2007-04-01
Magnetic resonance imaging (MRI) is the gold standard non-invasive technique to detect malignant disease in the bone marrow. Proton magnetic resonance spectroscopy (MRS) can be performed as a quick adjunct to routine spinal MRI. We performed proton MRS to patients with multiple myeloma (MM) at diagnosis and after treatment to investigate the possible correlation of MRS data with response to therapy. Twenty-one patients with newly diagnosed MM underwent combined MRI/MRS explorations of a transverse center section in the fifth lumbar vertebral body. MRS was acquired with STEAM and 40 ms TE. Areas of unsuppressed water and lipid resonances were used to calculate the lipid-to-water ratio (LWR). No association was detected between initial LWRs and the clinical characteristics of patients. Post treatment MRS was available in 16 patients of whom 11 (69%) presented an LWR increase, this included all complete responders (8/8, 100%, P = 0.012). A post-treatment LWR value equal to or larger than one is proposed as a non-invasive marker of complete response to treatment. Only patients responding to treatment presented a significant increase in bone marrow LWR after therapy. MRS may provide an adequate quantification of response to chemotherapy in patients with MM.
Characterization of methicillin-resistant Staphylococcus spp. isolated from dogs in Korea.
Jang, Yunho; Bae, Dong hwa; Cho, Jae-Keun; Bahk, Gyung Jin; Lim, Suk-Kyung; Lee, Young Ju
2014-11-01
Staphylococci were isolated from dogs in animal hospitals, animal shelters, and the Daegu PET EXPO to investigate the characteristics of circulating methicillin-resistant Staphylococcal (MRS) strains in companion animals in Korea. A total of 36/157 isolates were classified as MRS, and subdivided as follows: 1 methicillin-resistant Staphylococcus aureus (MRSA), 4 methicillin-resistant Staphylococcus epidermidis, 2 methicillin-resistant Staphylococcus haemolyticus, and 29 MRS spp. Among the 36 MRS isolates tested, 100% were resistant to oxacillin and penicillin, and at least 50% were resistant to sulfamethoxazole/trimethoprim (69.4%), erythromycin (63.9%), tetracycline (58.3%), cefoxitin (55.6%), clindamycin (50.0%) or pirlimycin (50.0%). Additionally, 34/36 MRS isolates (94.4%) were mecA positive, 15 of which were further classified as SCCmec type V, 6 isolates as type I, 4 isolates as type IIIb, 1 isolate as type IVa, 1 isolate as type IV, with 7 isolates being non-classifiable. The results of multilocus sequence typing and spa typing for the one MRSA strain were ST 72 (1-4-1-8-4-4-3) and spa t148. Our results provide evidence that companion animals like dogs may be MRS carriers, and that continued surveillance of MRS in companion animals is required to prevent increased incidences in humans.
Reconnaissance of the water resources of the Lonesome Valley area, Yavapai County, Arizona
Metzger, Donald G.
1957-01-01
In accordance with a request from its cooperating agency, the Arizona State Land Department, the U.S. Geological Survey has made a brief reconnaissance of the water resources of the Lonesome Valley area, Yavapai County, Ariz., to determine the probable hydrologic effects of a proposed dam on Lynx Creek. The construction of this dam has been proposed by the Arizona Game and Fish Department, for recreational and fish-cultural purposes. Data on the geology of the area were furnished by Mrs. Medora M. Krieger, geologist, Geologic Division, U.S. Geological Survey, and the map was prepared by Floyd R. Twenter, geologist, Ground Water Branch.
Cao, Han; Wang, Jing; Li, Yichen; Li, Dongyang; Guo, Jin; Hu, Yifei; Meng, Kai; He, Dian; Liu, Bin; Liu, Zheng; Qi, Han; Zhang, Ling
2017-09-18
To analyse trends in mortality and causes of death among children aged under 5 years in Beijing, China between 1992 and 2015 and to forecast under-5 mortality rates (U5MRs) for the period 2016-2020. An entire population-based epidemiological study was conducted. Data collection was based on the Child Death Reporting Card of the Beijing Under-5 Mortality Rate Surveillance Network. Trends in mortality and leading causes of death were analysed using the χ 2 test and SPSS 19.0 software. An autoregressive integrated moving average (ARIMA) model was fitted to forecast U5MRs between 2016 and 2020 using the EViews 8.0 software. Mortality in neonates, infants and children aged under 5 years decreased by 84.06%, 80.04% and 80.17% from 1992 to 2015, respectively. However, the U5MR increased by 7.20% from 2013 to 2015. Birth asphyxia, congenital heart disease, preterm/low birth weight and other congenital abnormalities comprised the top five causes of death. The greatest, most rapid reduction was that of pneumonia by 92.26%, with an annual average rate of reduction of 10.53%. The distribution of causes of death differed among children of different ages. Accidental asphyxia and sepsis were among the top five causes of death in children aged 28 days to 1 year and accident was among the top five causes in children aged 1-4 years. The U5MRs in Beijing are projected to be 2.88‰, 2.87‰, 2.90‰, 2.97‰ and 3.09‰ for the period 2016-2020, based on the predictive model. Beijing has made considerable progress in reducing U5MRs from 1992 to 2015. However, U5MRs could show a slight upward trend from 2016 to 2020. Future considerations for child healthcare include the management of birth asphyxia, congenital heart disease, preterm/low birth weight and other congenital abnormalities. Specific preventative measures should be implemented for children of various age groups. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Cao, Han; Wang, Jing; Li, Yichen; Li, Dongyang; Guo, Jin; Hu, Yifei; Meng, Kai; He, Dian; Liu, Bin; Liu, Zheng; Qi, Han; Zhang, Ling
2017-01-01
Objectives To analyse trends in mortality and causes of death among children aged under 5 years in Beijing, China between 1992 and 2015 and to forecast under-5 mortality rates (U5MRs) for the period 2016–2020. Methods An entire population-based epidemiological study was conducted. Data collection was based on the Child Death Reporting Card of the Beijing Under-5 Mortality Rate Surveillance Network. Trends in mortality and leading causes of death were analysed using the χ2 test and SPSS 19.0 software. An autoregressive integrated moving average (ARIMA) model was fitted to forecast U5MRs between 2016 and 2020 using the EViews 8.0 software. Results Mortality in neonates, infants and children aged under 5 years decreased by 84.06%, 80.04% and 80.17% from 1992 to 2015, respectively. However, the U5MR increased by 7.20% from 2013 to 2015. Birth asphyxia, congenital heart disease, preterm/low birth weight and other congenital abnormalities comprised the top five causes of death. The greatest, most rapid reduction was that of pneumonia by 92.26%, with an annual average rate of reduction of 10.53%. The distribution of causes of death differed among children of different ages. Accidental asphyxia and sepsis were among the top five causes of death in children aged 28 days to 1 year and accident was among the top five causes in children aged 1–4 years. The U5MRs in Beijing are projected to be 2.88‰, 2.87‰, 2.90‰, 2.97‰ and 3.09‰ for the period 2016–2020, based on the predictive model. Conclusion Beijing has made considerable progress in reducing U5MRs from 1992 to 2015. However, U5MRs could show a slight upward trend from 2016 to 2020. Future considerations for child healthcare include the management of birth asphyxia, congenital heart disease, preterm/low birth weight and other congenital abnormalities. Specific preventative measures should be implemented for children of various age groups. PMID:28928178
1990-06-01
five (5) years, not listed above, that were given formal performance ratings by Federal, state, or municipal agencies, or private companies. The format...Office Commissioned Corps, Public Health Service * Chief Mercado - Manpower Management - Naval Health Sciences Education and Training Command * Mrs...Secretary of the Director, Naval Dental School * Mr. William Fraunhurst - Director, Office Commissioned Corps, Putlic Health Service * Chief Mercado
Literary aesthetics: beauty, the brain, and Mrs. Dalloway.
Hogan, Patrick Colm
2013-01-01
Empirical research indicates that beauty is in part a matter of prototype approximation. Some research suggests that unanticipated pattern recognition is important as well. This essay begins by briefly outlining an account of beauty based on these factors. It goes on to consider complications. Minor complications include the partial incompatibility of these accounts and the importance of differentiating judgments of beauty from aesthetic response. More serious issues include the relative neglect of literature in neurologically-based discussions of beauty, which tend to focus on music or visual art. There is also a relative neglect of emotion, beyond the reward system. Finally, there is the almost complete absence of the sublime. After considering these problems broadly, the essay turns to Virginia Woolf's Mrs. Dalloway, examining its treatment of beauty and sublimity. The aim of this section is not merely to illuminate Woolf's novel by reference to neuroscientific research. It is equally, perhaps more fully, to expand our neuroscientifically grounded account of aesthetic response by drawing on Woolf's novel. In Mrs. Dalloway, there are gestures toward prototypes and patterns in beauty. But the key features are clearly emotional. Specifically, the emotions at issue in feelings of beauty and sublimity appear to be primarily attachment, on the one hand, and a profound sense of isolation, on the other. Woolf's novel also points us toward other features of aesthetic experience, crucially including the emotion-sharing that is a key function of the production and circulation of art. © 2013 Elsevier B.V. All rights reserved.
Tyagi, Avishkar; Yeganeh, Omid; Levin, Yakir; Hooker, Jonathan C; Hamilton, Gavin C; Wolfson, Tanya; Gamst, Anthony; Zand, Amir K; Heba, Elhamy; Loomba, Rohit; Schwimmer, Jeffrey; Middleton, Michael S; Sirlin, Claude B
2015-10-01
Determine intra- and inter-examination repeatability of magnitude-based magnetic resonance imaging (MRI-M), complex-based magnetic resonance imaging (MRI-C), and magnetic resonance spectroscopy (MRS) at 3T for estimating hepatic proton density fat fraction (PDFF), and using MRS as a reference, confirm MRI-M and MRI-C accuracy. Twenty-nine overweight and obese pediatric (n = 20) and adult (n = 9) subjects (23 male, 6 female) underwent three same-day 3T MR examinations. In each examination MRI-M, MRI-C, and single-voxel MRS were acquired three times. For each MRI acquisition, hepatic PDFF was estimated at the MRS voxel location. Intra- and inter-examination repeatability were assessed by computing standard deviations (SDs) and intra-class correlation coefficients (ICCs). Aggregate SD was computed for each method as the square root of the average of first repeat variances. MRI-M and MRI-C PDFF estimation accuracy was assessed using linear regression with MRS as a reference. For MRI-M, MRI-C, and MRS acquisitions, respectively, mean intra-examination SDs were 0.25%, 0.42%, and 0.49%; mean intra-examination ICCs were 0.999, 0.997, and 0.995; mean inter-examination SDs were 0.42%, 0.45%, and 0.46%; and inter-examination ICCs were 0.995, 0.992, and 0.990. Aggregate SD for each method was <0.9%. Using MRS as a reference, regression slope, intercept, average bias, and R (2), respectively, for MRI-M were 0.99%, 1.73%, 1.61%, and 0.986, and for MRI-C were 0.96%, 0.43%, 0.40%, and 0.991. MRI-M, MRI-C, and MRS showed high intra- and inter-examination hepatic PDFF estimation repeatability in overweight and obese subjects. Longitudinal hepatic PDFF change >1.8% (twice the maximum aggregate SD) may represent real change rather than measurement imprecision. Further research is needed to assess whether examinations performed on different days or with different MR technologists affect repeatability of MRS voxel placement and MRS-based PDFF measurements.
Tyagi, Avishkar; Yeganeh, Omid; Levin, Yakir; Hooker, Jonathan C.; Hamilton, Gavin C.; Wolfson, Tanya; Gamst, Anthony; Zand, Amir K.; Heba, Elhamy; Loomba, Rohit; Schwimmer, Jeffrey; Middleton, Michael S.; Sirlin, Claude B.
2016-01-01
Purpose Determine intra- and inter-examination repeatability of magnitude-based magnetic resonance imaging (MRI-M), complex-based magnetic resonance imaging (MRI-C), and magnetic resonance spectroscopy (MRS) at 3T for estimating hepatic proton density fat fraction (PDFF), and using MRS as a reference, confirm MRI-M and MRI-C accuracy. Methods Twenty-nine overweight and obese pediatric (n = 20) and adult (n = 9) subjects (23 male, 6 female) underwent three same-day 3T MR examinations. In each examination MRI-M, MRI-C, and single-voxel MRS were acquired three times. For each MRI acquisition, hepatic PDFF was estimated at the MRS voxel location. Intra- and inter-examination repeatability were assessed by computing standard deviations (SDs) and intra-class correlation coefficients (ICCs). Aggregate SD was computed for each method as the square root of the average of first repeat variances. MRI-M and MRI-C PDFF estimation accuracy was assessed using linear regression with MRS as a reference. Results For MRI-M, MRI-C, and MRS acquisitions, respectively, mean intra-examination SDs were 0.25%, 0.42%, and 0.49%; mean intra-examination ICCs were 0.999, 0.997, and 0.995; mean inter-examination SDs were 0.42%, 0.45%, and 0.46%; and inter-examination ICCs were 0.995, 0.992, and 0.990. Aggregate SD for each method was <0.9%. Using MRS as a reference, regression slope, intercept, average bias, and R2, respectively, for MRI-M were 0.99%, 1.73%, 1.61%, and 0.986, and for MRI-C were 0.96%, 0.43%, 0.40%, and 0.991. Conclusion MRI-M, MRI-C, and MRS showed high intra- and inter-examination hepatic PDFF estimation repeatability in overweight and obese subjects. Longitudinal hepatic PDFF change >1.8% (twice the maximum aggregate SD) may represent real change rather than measurement imprecision. Further research is needed to assess whether examinations performed on different days or with different MR technologists affect repeatability of MRS voxel placement and MRS-based PDFF measurements. PMID:26350282
Lee, May Yin; Racine, Victor; Jagadpramana, Peter; Sun, Li; Yu, Weimiao; Du, Tiehua; Spencer-Dene, Bradley; Rubin, Nicole; Le, Lendy; Ndiaye, Delphine; Bellusci, Saverio; Kratochwil, Klaus; Veltmaat, Jacqueline M.
2011-01-01
Mammary gland development starts in utero with one or several pairs of mammary rudiments (MRs) budding from the surface ectodermal component of the mammalian embryonic skin. Mice develop five pairs, numbered MR1 to MR5 from pectoral to inguinal position. We have previously shown that Gli3Xt-J/Xt-J mutant embryos, which lack the transcription factor Gli3, do not form MR3 and MR5. We show here that two days after the MRs emerge, Gli3Xt-J/Xt-J MR1 is 20% smaller, and Gli3Xt-J/Xt-J MR2 and MR4 are 50% smaller than their wild type (wt) counterparts. Moreover, while wt MRs sink into the underlying dermis, Gli3Xt-J/Xt-J MR4 and MR2 protrude outwardly, to different extents. To understand why each of these five pairs of functionally identical organs has its own, distinct response to the absence of Gli3, we determined which cellular mechanisms regulate growth of the individual MRs, and whether and how Gli3 regulates these mechanisms. We found a 5.5 to 10.7-fold lower cell proliferation rate in wt MRs compared to their adjacent surface ectoderm, indicating that MRs do not emerge or grow via locally enhanced cell proliferation. Cell-tracing experiments showed that surface ectodermal cells are recruited toward the positions where MRs emerge, and contribute to MR growth during at least two days. During the second day of MR development, peripheral cells within the MRs undergo hypertrophy, which also contributes to MR growth. Limited apoptotic cell death counterbalances MR growth. The relative contribution of each of these processes varies among the five MRs. Furthermore, each of these processes is impaired in the absence of Gli3, but to different extents in each MR. This differential involvement of Gli3 explains the variation in phenotype among Gli3Xt-J/Xt-J MRs, and may help to understand the variation in numbers and positions of mammary glands among mammals. PMID:22046263
Secchi, Francesco; Di Leo, Giovanni; Petrini, Marcello; Spairani, Riccardo; Alì, Marco; Guazzi, Marco; Sardanelli, Francesco
2017-04-01
The clinical differentiation between athlete's heart and mild forms of non-obstructive hypertrophic cardiomyopathy (HCM) is crucial. We hypothesized that differences do exist between the myocardial metabolism of patients with non-obstructive HCM and competitive athletes (CAs). Our aim was to evaluate myocardial metabolism with 31 P-MRS and 1 H-MRS in HCM patients and CAs. After Ethics Committee approval, 15 CAs and 7 HCM patients were prospectively enrolled. They underwent a 1.5-T cardiac MR including electrocardiographically triggered cine images, single-voxel 1 H-MRS and multivoxel 31 P-MRS. 1 H-MRS was performed after imaging using standard coil with the patient in the supine position; thereafter, 31 P-MRS was performed using a dedicated coil, in the prone position. Data were reported as median and interquartile range. Mann-Whitney U test was used. In CAs, left ventricular mass index was 72 (66-83) g/m 2 , septal thickness 10 (10-11) mm, end diastolic volume index 95 (85-102) ml/m 2 , end systolic volume index 30 (28-32) ml/m 2 and ejection fraction 68% (65-69%); in HCM patients, 81 (76-111) g/m 2 (P = 0.052), 18 (15-21) mm (P = 0.003), 73 (58-76) ml/m 2 (P = 0.029), 20 (16-34) ml/m 2 (P = 0.274) and 68% (55-73%) (P = 1.000), respectively. At 1 H-MRS, total lipids were 35 (0-183) arbitrary units (au) for CA and 763 (155-1994) au for HCM patients (P = 0.046). At 31 P-MRS, PCr/γATP was 5 (4-6) au for CA and 4 (2-5) au for HCM patients (P = 0.230). Examination time was 20 min for imaging only, 5 min for 1 H-MRS and 15 min for 31 P-MRS. We observed a significant increase of myocardial lipids, but a preserved PCr/γATP ratio in the metabolism of HCM patients compared with competitive CAs.
Song, Kyu-Ho; Kim, Sang-Young; Lee, Do-Wan; Jung, Jin-Young; Lee, Jung-Hoon; Baek, Hyeon-Man; Choe, Bo-Young
2015-11-30
Magnetic resonance imaging and spectroscopy (MRI-MRS) is a useful tool for the identification and evaluation of chemical changes in anatomical regions. Quality assurance (QA) is performed in either images or spectra using QA phantom. Therefore, consistent and uniform technical MRI-MRS QA is crucial. Here we developed an MRI-MRS fused phantom along with the inserts for metabolite quantification to simultaneously optimize QA parameters for both MRI and MRS. T1- and T2-weighted images were obtained and MRS was performed with point-resolved spectroscopy. Using the fused phantom, the results of measuring MRI factors were: geometric distortion, <2% and ± 2 mm; image intensity uniformity, 83.09 ± 1.33%; percent-signal ghosting, 0.025 ± 0.004; low-contrast object detectability, 27.85 ± 0.80. In addition, the signal-to-noise ratio of N-acetyl-aspartate was consistently high (42.00 ± 5.66). In previous studies, MR phantoms could not obtain information from both images and spectra in the MR scanner simultaneously. Here we designed and developed a phantom for accurate and consistent QA within the acceptance range. It is important to take into account variations in the QA value using the MRI-MRS phantom, when comparing to other clinical or research MR scanners. The MRI-MRS QA factors obtained simultaneously using the phantom can facilitate evaluation of both images and spectra, and provide guidelines for obtaining MRI and MRS QA factors simultaneously. Copyright © 2015 Elsevier B.V. All rights reserved.
Solga, Steven F.; Horska, Alena; Hemker, Susanne; Crawford, Stephen; Diggs, Charalett; Diehl, Anna Mae; Brancati, Frederick L.; Clark, Jeanne M.
2009-01-01
Background/Aims Magnetic resonance spectroscopy (MRS) measures hepatic fat and adenosine triphosphate (ATP), but magnetic resonance studies are challenging in obese subjects. We aimed to evaluate the inter- and intrarater reliability and stability of hepatic fat and ATP measurements in a cohort of overweight and obese adults. Methods We measured hepatic fat and ATP using proton MRS (1H MRS) and phosphorus MRS (31P MRS) at baseline in adults enrolled in the Action for Health in Diabetes (Look AHEAD) clinical trial at one site. Using logistic regression, we determined factors associated with successful MRS data acquisition. We calculated the intra- and inter-rater reliability for hepatic fat and ATP based on 20 scans analysed twice by two readers. We also calculated the stability of these measures three times on five healthy volunteers. Results Of 244 participants recruited into our ancillary study, 185 agreed to MRS. We obtained usable hepatic fat data from 151 (82%) and ATP data from 105 (58%). Obesity was the strongest predictor of failed data acquisition; every unit increase in the body mass index reduced the likelihood of successful fat data by 11% and ATP data by 14%. The inter- and intrarater reliability were excellent for fat (intraclass correlation coefficient = 0.99), but substantially more variable for ATP. Fat measures appeared relatively stable, but this was less true for ATP. Conclusions Obesity can hinder 1H and 31P MRS data acquisition and subsequent analysis. This impact was greater for hepatic ATP than hepatic fat. PMID:18331237
Proton magnetic resonance spectroscopy for assessment of human body composition.
Kamba, M; Kimura, K; Koda, M; Ogawa, T
2001-02-01
The usefulness of magnetic resonance spectroscopy (MRS)-based techniques for assessment of human body composition has not been established. We compared a proton MRS-based technique with the total body water (TBW) method to determine the usefulness of the former technique for assessment of human body composition. Proton magnetic resonance spectra of the chest to abdomen, abdomen to pelvis, and pelvis to thigh regions were obtained from 16 volunteers by using single, free induction decay measurement with a clinical magnetic resonance system operating at 1.5 T. The MRS-derived metabolite ratio was determined as the ratio of fat methyl and methylene proton resonance to water proton resonance. The peak areas for the chest to abdomen and the pelvis to thigh regions were normalized to an external reference (approximately 2200 g benzene) and a weighted average of the MRS-derived metabolite ratios for the 2 positions was calculated. TBW for each subject was determined by the deuterium oxide dilution technique. The MRS-derived metabolite ratios were significantly correlated with the ratio of body fat to lean body mass estimated by TBW. The MRS-derived metabolite ratio for the abdomen to pelvis region correlated best with the ratio of body fat to lean body mass on simple regression analyses (r = 0.918). The MRS-derived metabolite ratio for the abdomen to pelvis region and that for the pelvis to thigh region were selected for a multivariate regression model (R = 0.947, adjusted R(2) = 0.881). This MRS-based technique is sufficiently accurate for assessment of human body composition.
d'Assignies, Gaspard; Fontés, Ghislaine; Kauffmann, Claude; Latour, Martin; Gaboury, Louis; Boulanger, Yvan; Van Beers, Bernard E; Soulez, Gilles; Poitout, Vincent; Tang, An
2013-12-01
Magnetic resonance (MR) techniques allow noninvasive fat quantification. We aimed to investigate the accuracy of MR imaging (MRI), MR spectroscopy (MRS) and histological techniques to detect early-onset liver steatosis in three rat phenotypes assigned to an experimental glucolipotoxic model or a control group. This study was approved by the institutional committee for the protection of animals. Thirty-two rats (13 young Wistar, 6 old Wistar and 13 diabetic Goto-Kakizaki rats) fed a standard diet were assigned to a 72h intravenous infusion of glucose and Intralipid fat emulsion or a saline infusion. Plasma insulin levels were measured. Steatosis was quantified in ex vivo livers with gradient-recalled multi-echo MRI, MRS and histology as fat fractions (FF). A significant correlation was found between multi-echo MRI-FF and MRS-FF (r=0.81, p<0.01) and a weaker correlation was found between histology and MRS-FF (r=0.60, p<0.01). MRS and MRI accurately distinguished young Wistar and Goto-Kakizaki rats receiving the glucose+Intralipid infusion from those receiving the saline control whereas histology did not. Significant correlations were found between MRI or MRS and insulin plasma level (r=0.63, p<0.01; r=0.57, p<0.01), and between MRI or MRS and C-peptide concentration (r=0.54, p<0.01; r=0.44, p<0.02). Multi-echo MRI and MRS may be more sensitive to measure early-onset liver steatosis than histology in an experimental glucolipotoxic rat model. © 2013.
Differential Item Functioning of the Psychological Domain of the Menopause Rating Scale.
Monterrosa-Castro, Alvaro; Portela-Buelvas, Katherin; Oviedo, Heidi C; Herazo, Edwin; Campo-Arias, Adalberto
2016-01-01
Introduction. Quality of life could be quantified with the Menopause Rating Scale (MRS), which evaluates the severity of somatic, psychological, and urogenital symptoms in menopause. However, differential item functioning (DIF) analysis has not been applied previously. Objective . To establish the DIF of the psychological domain of the MRS in Colombian women. Methods . 4,009 women aged between 40 and 59 years, who participated in the CAVIMEC (Calidad de Vida en la Menopausia y Etnias Colombianas) project, were included. Average age was 49.0 ± 5.9 years. Women were classified in mestizo, Afro-Colombian, and indigenous. The results were presented as averages and standard deviation ( X ± SD). A p value <0.001 was considered statistically significant. Results . In mestizo women, the highest X ± SD were obtained in physical and mental exhaustion (PME) (0.86 ± 0.93) and the lowest ones in anxiety (0.44 ± 0.79). In Afro-Colombian women, an average score of 0.99 ± 1.07 for PME and 0.63 ± 0.88 for anxiety was gotten. Indigenous women obtained an increased average score for PME (1.33 ± 0.93). The lowest score was evidenced in depressive mood (0.50 ± 0.81), which is different from other Colombian women ( p < 0.001). Conclusions . The psychological items of the MRS show differential functioning according to the ethnic group, which may induce systematic error in the measurement of the construct.
Differential Item Functioning of the Psychological Domain of the Menopause Rating Scale
Portela-Buelvas, Katherin; Oviedo, Heidi C.; Herazo, Edwin; Campo-Arias, Adalberto
2016-01-01
Introduction. Quality of life could be quantified with the Menopause Rating Scale (MRS), which evaluates the severity of somatic, psychological, and urogenital symptoms in menopause. However, differential item functioning (DIF) analysis has not been applied previously. Objective. To establish the DIF of the psychological domain of the MRS in Colombian women. Methods. 4,009 women aged between 40 and 59 years, who participated in the CAVIMEC (Calidad de Vida en la Menopausia y Etnias Colombianas) project, were included. Average age was 49.0 ± 5.9 years. Women were classified in mestizo, Afro-Colombian, and indigenous. The results were presented as averages and standard deviation (X ± SD). A p value <0.001 was considered statistically significant. Results. In mestizo women, the highest X ± SD were obtained in physical and mental exhaustion (PME) (0.86 ± 0.93) and the lowest ones in anxiety (0.44 ± 0.79). In Afro-Colombian women, an average score of 0.99 ± 1.07 for PME and 0.63 ± 0.88 for anxiety was gotten. Indigenous women obtained an increased average score for PME (1.33 ± 0.93). The lowest score was evidenced in depressive mood (0.50 ± 0.81), which is different from other Colombian women (p < 0.001). Conclusions. The psychological items of the MRS show differential functioning according to the ethnic group, which may induce systematic error in the measurement of the construct. PMID:27847825
ACHP | News | Mrs. Laura Bush Presents "Preserve America History Teacher
. Laura Bush Presents "Preserve America History Teacher of the Year" Award to New Jersey Teacher Mrs. Laura Bush Presents "Preserve America History Teacher of the Year" Award to New Jersey Teacher October 14, 2005 Mrs. Laura Bush Presents "Preserve America History Teacher of the Year"
Overlap of copper and iron uptake systems in mitochondria in Saccharomyces cerevisiae
Wang, Jing; Gammon, Micah G.; Maynard, Margaret K.; White, Olivia L.; Cobine, Jai A.; Mahone, Wilkerson K.
2016-01-01
In Saccharomyces cerevisiae, the mitochondrial carrier family protein Pic2 imports copper into the matrix. Deletion of PIC2 causes defects in mitochondrial copper uptake and copper-dependent growth phenotypes owing to decreased cytochrome c oxidase activity. However, copper import is not completely eliminated in this mutant, so alternative transport systems must exist. Deletion of MRS3, a component of the iron import machinery, also causes a copper-dependent growth defect on non-fermentable carbon. Deletion of both PIC2 and MRS3 led to a more severe respiratory growth defect than either individual mutant. In addition, MRS3 expressed from a high copy number vector was able to suppress the oxygen consumption and copper uptake defects of a strain lacking PIC2. When expressed in Lactococcus lactis, Mrs3 mediated copper and iron import. Finally, a PIC2 and MRS3 double mutant prevented the copper-dependent activation of a heterologously expressed copper sensor in the mitochondrial intermembrane space. Taken together, these data support a role for the iron transporter Mrs3 in copper import into the mitochondrial matrix. PMID:26763345
Sun, Baochun; Zhou, Chengyong; Han, Zeli
2015-02-01
The aim of this study was to compare genetic predilection and recurrence tendency between facial palsy in Melkersson-Rosenthal syndrome (MRS) and Bell's palsy We carried out an investigation on patients with facial palsy in MRS and those with Bell's palsy who visited the outpatient department in our hospital between February 2009 and February 2013. They were asked about familial history and whether it was the first episode, with the results recorded and compared. There were 16 patients with facial palsy in MRS and 860 patients with Bell's palsy involved in the study. Familial history was positive in 5 of 16 patients (31.3%) with facial palsy in MRS and 56 of 860 patients (6.5%) with Bell's palsy (P < .01). Twelve of 16 cases (75%) with facial palsy in MRS and 88 of 860 cases (10.2%) with Bell's palsy had a history of facial palsy in the past (P < .01). Compared to Bell's palsy, facial palsy in MRS has an obvious genetic predilection and recurrence tendency. © The Author(s) 2014.
Tseng, Jill H; Aloisi, Alessia; Sonoda, Yukio; Gardner, Ginger J; Zivanovic, Oliver; Abu-Rustum, Nadeem R; Leitao, Mario M
2018-05-15
Standard surgical treatment for women with stage IB1 cervical cancer consists of radical hysterectomy. This study assesses survival outcomes of those treated with less radical surgery (LRS; conization, trachelectomy, simple hysterectomy) compared to more radical surgery (MRS; modified radical, radical hysterectomy). Using the Surveillance, Epidemiology and End Results database, we identified women <45 years with FIGO stage IB1 cervical cancer diagnosed from 1/1998 to 12/2012. Only those who underwent lymph node (LN) assessment were analyzed. Disease-specific survivals (DSSs) of LRS were compared with those of MRS. Of 2571 patients, 807 underwent LRS and 1764 underwent MRS, all with LN assessment. For LRS vs. MRS, 28% vs. 23% were diagnosed with adenocarcinoma (p = 0.024), 31% vs. 39% had G3 disease (p < 0.001), 40% vs. 45% had tumor size >2 cm (p < 0.001), and 27% vs. 29% received adjuvant radiation therapy (p = 0.005). Median follow-up was 79 months (range, 0-179). Ten-year DSS for LRS vs. MRS was 93.5% vs. 92.3% (p = 0.511). There was no difference in 10-year DSS when stratified by tumor size ≤2 cm (LRS 95.1% vs. MRS 95.6%, p = 0.80) or > 2 cm (LRS 90.1% vs. MRS 88.2%, p = 0.48). Factors independently associated with increased risk of death included adenosquamous histology (HR 2.37), G3 disease (HR 2.86), tumors >2 cm (HR 1.82), and LN positivity (HR 2.42). Compared to MRS, LRS was not associated with a higher risk of death. In a select group of young women with stage IB1 cervical cancer, LRS compared to MRS does not appear to compromise DSS. Copyright © 2018 Elsevier Inc. All rights reserved.
Lee, Seung Soo; Lee, Youngjoo; Kim, Namkug; Kim, Seong Who; Byun, Jae Ho; Park, Seong Ho; Lee, Moon-Gyu; Ha, Hyun Kwon
2011-06-01
To compare the accuracy of four chemical shift magnetic resonance imaging (MRI) (CS-MRI) analysis methods and MR spectroscopy (MRS) with and without T2-correction in fat quantification in the presence of excess iron. CS-MRI with six opposed- and in-phase acquisitions and MRS with five-echo acquisitions (TEs of 20, 30, 40, 50, 60 msec) were performed at 1.5 T on phantoms containing various fat fractions (FFs), on phantoms containing various iron concentrations, and in 18 patients with chronic liver disease. For CS-MRI, FFs were estimated with the dual-echo method, with two T2*-correction methods (triple- and multiecho), and with multiinterference methods that corrected for both T2* and spectral interference effects. For MRS, FF was estimated without T2-correction (single-echo MRS) and with T2-correction (multiecho MRS). In the phantoms, T2*- or T2-correction methods for CS-MRI and MRS provided unbiased estimations of FFs (mean bias, -1.1% to 0.5%) regardless of iron concentration, whereas the dual-echo method (-5.5% to -8.4%) and single-echo MRS (12.1% to 37.3%) resulted in large biases in FFs. In patients, the FFs estimated with triple-echo (R = 0.98), multiecho (R = 0.99), and multiinterference (R = 0.99) methods had stronger correlations with multiecho MRS FFs than with the dual-echo method (R = 0.86; P ≤ 0.011). The FFs estimated with multiinterference method showed the closest agreement with multiecho MRS FFs (the 95% limit-of-agreement, -0.2 ± 1.1). T2*- or T2-correction methods are effective in correcting the confounding effects of iron, enabling an accurate fat quantification throughout a wide range of iron concentrations. Spectral modeling of fat may further improve the accuracy of CS-MRI in fat quantification. Copyright © 2011 Wiley-Liss, Inc.
Mandava, Pitchaiah; Krumpelman, Chase S; Shah, Jharna N; White, Donna L; Kent, Thomas A
2013-01-01
Clinical trial outcomes often involve an ordinal scale of subjective functional assessments but the optimal way to quantify results is not clear. In stroke, the most commonly used scale, the modified Rankin Score (mRS), a range of scores ("Shift") is proposed as superior to dichotomization because of greater information transfer. The influence of known uncertainties in mRS assessment has not been quantified. We hypothesized that errors caused by uncertainties could be quantified by applying information theory. Using Shannon's model, we quantified errors of the "Shift" compared to dichotomized outcomes using published distributions of mRS uncertainties and applied this model to clinical trials. We identified 35 randomized stroke trials that met inclusion criteria. Each trial's mRS distribution was multiplied with the noise distribution from published mRS inter-rater variability to generate an error percentage for "shift" and dichotomized cut-points. For the SAINT I neuroprotectant trial, considered positive by "shift" mRS while the larger follow-up SAINT II trial was negative, we recalculated sample size required if classification uncertainty was taken into account. Considering the full mRS range, error rate was 26.1%±5.31 (Mean±SD). Error rates were lower for all dichotomizations tested using cut-points (e.g. mRS 1; 6.8%±2.89; overall p<0.001). Taking errors into account, SAINT I would have required 24% more subjects than were randomized. We show when uncertainty in assessments is considered, the lowest error rates are with dichotomization. While using the full range of mRS is conceptually appealing, a gain of information is counter-balanced by a decrease in reliability. The resultant errors need to be considered since sample size may otherwise be underestimated. In principle, we have outlined an approach to error estimation for any condition in which there are uncertainties in outcome assessment. We provide the user with programs to calculate and incorporate errors into sample size estimation.
Einstein, Samuel A.; Weegman, Bradley P.; Firpo, Meri T.; Papas, Klearchos K.
2016-01-01
Techniques to monitor the oxygen partial pressure (pO2) within implanted tissue-engineered grafts (TEGs) are critically necessary for TEG development, but current methods are invasive and inaccurate. In this study, we developed an accurate and noninvasive technique to monitor TEG pO2 utilizing proton (1H) or fluorine (19F) magnetic resonance spectroscopy (MRS) relaxometry. The value of the spin-lattice relaxation rate constant (R1) of some biocompatible compounds is sensitive to dissolved oxygen (and temperature), while insensitive to other external factors. Through this physical mechanism, MRS can measure the pO2 of implanted TEGs. We evaluated six potential MRS pO2 probes and measured their oxygen and temperature sensitivities and their intrinsic R1 values at 16.4 T. Acellular TEGs were constructed by emulsifying porcine plasma with perfluoro-15-crown-5-ether, injecting the emulsion into a macroencapsulation device, and cross-linking the plasma with a thrombin solution. A multiparametric calibration equation containing R1, pO2, and temperature was empirically generated from MRS data and validated with fiber optic (FO) probes in vitro. TEGs were then implanted in a dorsal subcutaneous pocket in a murine model and evaluated with MRS up to 29 days postimplantation. R1 measurements from the TEGs were converted to pO2 values using the established calibration equation and these in vivo pO2 measurements were simultaneously validated with FO probes. Additionally, MRS was used to detect increased pO2 within implanted TEGs that received supplemental oxygen delivery. Finally, based on a comparison of our MRS data with previously reported data, ultra-high-field (16.4 T) is shown to have an advantage for measuring hypoxia with 19F MRS. Results from this study show MRS relaxometry to be a precise, accurate, and noninvasive technique to monitor TEG pO2 in vitro and in vivo. PMID:27758135
Einstein, Samuel A; Weegman, Bradley P; Firpo, Meri T; Papas, Klearchos K; Garwood, Michael
2016-11-01
Techniques to monitor the oxygen partial pressure (pO 2 ) within implanted tissue-engineered grafts (TEGs) are critically necessary for TEG development, but current methods are invasive and inaccurate. In this study, we developed an accurate and noninvasive technique to monitor TEG pO 2 utilizing proton ( 1 H) or fluorine ( 19 F) magnetic resonance spectroscopy (MRS) relaxometry. The value of the spin-lattice relaxation rate constant (R 1 ) of some biocompatible compounds is sensitive to dissolved oxygen (and temperature), while insensitive to other external factors. Through this physical mechanism, MRS can measure the pO 2 of implanted TEGs. We evaluated six potential MRS pO 2 probes and measured their oxygen and temperature sensitivities and their intrinsic R 1 values at 16.4 T. Acellular TEGs were constructed by emulsifying porcine plasma with perfluoro-15-crown-5-ether, injecting the emulsion into a macroencapsulation device, and cross-linking the plasma with a thrombin solution. A multiparametric calibration equation containing R 1 , pO 2 , and temperature was empirically generated from MRS data and validated with fiber optic (FO) probes in vitro. TEGs were then implanted in a dorsal subcutaneous pocket in a murine model and evaluated with MRS up to 29 days postimplantation. R 1 measurements from the TEGs were converted to pO 2 values using the established calibration equation and these in vivo pO 2 measurements were simultaneously validated with FO probes. Additionally, MRS was used to detect increased pO 2 within implanted TEGs that received supplemental oxygen delivery. Finally, based on a comparison of our MRS data with previously reported data, ultra-high-field (16.4 T) is shown to have an advantage for measuring hypoxia with 19 F MRS. Results from this study show MRS relaxometry to be a precise, accurate, and noninvasive technique to monitor TEG pO 2 in vitro and in vivo.
Andó, RD; Méhész, B; Gyires, K; Illes, P; Sperlágh, B
2010-01-01
Background and purpose: This study was undertaken to compare the analgesic activity of antagonists acting at P2X1, P2X7, and P2Y12 receptors and agonists acting at P2Y1, P2Y2, P2Y4, and P2Y6 receptors in neuropathic, acute, and inflammatory pain. Experimental approach: The effect of the wide spectrum P2 receptor antagonist PPADS, the selective P2X7 receptor antagonist Brilliant Blue G (BBG), the P2X1 receptor antagonist (4,4′,4″,4-[carbonylbis(imino-5,1,3-benzenetriyl-bis(carbonylimino))]tetrakis-1,3-benzenedisulfonic acid, octasodium salt (NF449) and (8,8′-[carbonylbis(imino-3,1-phenylenecarbonylimino)]bis-1,3,5-naphthalene-trisulphonic acid, hexasodium salt (NF023), the P2Y12 receptor antagonist (2,2-dimethyl-propionic acid 3-(2-chloro-6-methylaminopurin-9-yl)-2-(2,2-dimethyl-propionyloxymethyl)-propylester (MRS2395), the selective P2Y1 receptor agonist ([[(1R,2R,3S,4R,5S)-4-[6-amino-2-(methylthio)-9H-purin-9-yl]-2,3-dihydroxybicyclo[3.1.0]hex-1-yl]methyl] diphosphoric acid mono ester trisodium salt (MRS2365), the P2Y2/P2Y4 agonist uridine-5′-triphosphate (UTP), and the P2Y4/P2Y6 agonist uridine-5′-diphosphate (UDP) were examined on mechanical allodynia in the Seltzer model of neuropathic pain, on acute thermal nociception, and on the inflammatory pain and oedema induced by complete Freund's adjuvant (CFA). Key results: MRS2365, MRS2395 and UTP, but not the other compounds, significantly alleviated mechanical allodynia in the neuropathic pain model, with the following rank order of minimal effective dose (mED) values: MRS2365 > MRS2395 > UTP. All compounds had a dose-dependent analgesic action in acute pain except BBG, which elicited hyperalgesia at a single dose. The rank order of mED values in acute pain was the following: MRS2365 > MRS2395 > NF449 > NF023 > UDP = UTP > PPADS. MRS2365 and MRS2395 had a profound, while BBG had a mild effect on inflammatory pain, with a following rank order of mED values: MRS2395 > MRS2365 > BBG. None of the tested compounds had significant action on oedema evoked by intraplantar injection of CFA. Conclusions and implications: Our results show that antagonism at P2X1, P2Y12, and P2X7 receptors and agonism at P2Y1 receptors define promising therapeutic strategies in acute, neuropathic, and inflammatory pain respectively. PMID:20136836
Andó, R D; Méhész, B; Gyires, K; Illes, P; Sperlágh, B
2010-03-01
This study was undertaken to compare the analgesic activity of antagonists acting at P2X1, P2X7, and P2Y12 receptors and agonists acting at P2Y1, P2Y2, P2Y4, and P2Y6 receptors in neuropathic, acute, and inflammatory pain. The effect of the wide spectrum P2 receptor antagonist PPADS, the selective P2X7 receptor antagonist Brilliant Blue G (BBG), the P2X1 receptor antagonist (4,4',4'',4-[carbonylbis(imino-5,1,3-benzenetriyl-bis(carbonylimino))]tetrakis-1,3-benzenedisulfonic acid, octasodium salt (NF449) and (8,8'-[carbonylbis(imino-3,1-phenylenecarbonylimino)]bis-1,3,5-naphthalene-trisulphonic acid, hexasodium salt (NF023), the P2Y12 receptor antagonist (2,2-dimethyl-propionic acid 3-(2-chloro-6-methylaminopurin-9-yl)-2-(2,2-dimethyl-propionyloxymethyl)-propylester (MRS2395), the selective P2Y1 receptor agonist ([[(1R,2R,3S,4R,5S)-4-[6-amino-2-(methylthio)-9H-purin-9-yl]-2,3-dihydroxybicyclo[3.1.0]hex-1-yl]methyl] diphosphoric acid mono ester trisodium salt (MRS2365), the P2Y2/P2Y4 agonist uridine-5'-triphosphate (UTP), and the P2Y4/P2Y6 agonist uridine-5'-diphosphate (UDP) were examined on mechanical allodynia in the Seltzer model of neuropathic pain, on acute thermal nociception, and on the inflammatory pain and oedema induced by complete Freund's adjuvant (CFA). MRS2365, MRS2395 and UTP, but not the other compounds, significantly alleviated mechanical allodynia in the neuropathic pain model, with the following rank order of minimal effective dose (mED) values: MRS2365 > MRS2395 > UTP. All compounds had a dose-dependent analgesic action in acute pain except BBG, which elicited hyperalgesia at a single dose. The rank order of mED values in acute pain was the following: MRS2365 > MRS2395 > NF449 > NF023 > UDP = UTP > PPADS. MRS2365 and MRS2395 had a profound, while BBG had a mild effect on inflammatory pain, with a following rank order of mED values: MRS2395 > MRS2365 > BBG. None of the tested compounds had significant action on oedema evoked by intraplantar injection of CFA. Our results show that antagonism at P2X1, P2Y12, and P2X7 receptors and agonism at P2Y1 receptors define promising therapeutic strategies in acute, neuropathic, and inflammatory pain respectively.
President and Mrs. Clinton watch launch of Space Shuttle Discovery
NASA Technical Reports Server (NTRS)
1998-01-01
From the roof of the Launch Control Center, U.S. President Bill Clinton and First Lady Hillary Rodham Clinton track the plume and successful launch of Space Shuttle Discovery on mission STS-95. This was the first launch of a Space Shuttle to be viewed by President Clinton, or any President to date. They attended the launch to witness the return to space of American legend John H. Glenn Jr., payload specialist on the mission.
Articulating Value: A framework for Evaluating Military Retirement Alternatives
2012-11-30
Retirement System (MRS) is expensive. In FY2010, the US Government spent over $50 Billion on military retirement (DoD Office of the Actuary , Valuation...SBP is shared by the retiree and the government, thus it is not self- sustaining (DoD Office of the Actuaries , Valuation, 43-48). 1.3 Methodology...the military retirement fund and the cash paid to retirees during the year exceeded $50 billion (DoD Office of the Actuary , Valuation, 19-20). The
General of the Army George C. Marshall on Operational Leadership
2007-11-06
used soldiers from 6 states and the regular Army.24 The regular Army soon sent Marshall back to the Philippines. In very short order he was...thousand in overseas maneuvers where they “put to sea, landed…and advanced [sixty miles] on Manila…[as] an invading force hostile to the US .” The...Marshall’s candor. He demonstrated it by openly criticizing Bell for making too many speeches. The criticism even caused discomfort with Mrs. Bell
Yilmaz, Adem; Musluman, Ahmet Murat; Kanat, Ayhan; Cavusoglu, Halit; Terzi, Yuksel; Aydin, Yunus
2011-01-01
The correlation between hematoma volume and outcome in ruptured arteriovenous malformations (AVM) with accompanying posterior fossa hematoma was retrospectively evaluated. Microsurgery operations were performed on 127 patients with intracranial AVM between January 1998 and January 2009 at our clinic. Fifteen (11.8%) patients were identified as suffering from posterior fossa AVM, and twelve of these patients presented with a cerebellar hematoma. All patients were clinically evaluated according to the following criteria: modified Rankin Scale (mRS) prior to surgery, Spetzler-Martin grade (SMG) of the AVMs, hematoma volume prior to surgery, and mRS following surgery. Postoperative mRS scores were significantly lower than preoperative scores (p=0.0001). Postoperative outcomes were concordant with the SMG of the AVMs (r=0.67, p=0.033), hematoma volume (r=0.537, p=0.072) and preoperative mRS scores (r=0.764, p=0.004). These analyses show that the postoperative mRS score is strongly correlated with a preoperative mRS score, hematoma volume and SMG. Posterior fossa AVMs present an increased risk for hemorrhage and for increased morbidity and mortality. Cases with hematoma should be operated on an urgent basis. We conclude that hematoma volume is a factor that impacts postoperative results and prognosis. SMG and preoperative mRS scores were also correlated with outcome.
"To the Lighthouse": The New Story of Mother and Daughter.
ERIC Educational Resources Information Center
Heilbrun, Carolyn G.
1987-01-01
Argues that the relationship between Lily and Mrs. Ramsey in Woolf's "To the Lighthouse" is a form of the Oedipal story. According to the theory, Lily must resist Mrs. Ramsey's effort to entice her into the traditional female role and recognize that she can be separate from Mrs. Ramsey's world and still love her. (JC)
Code of Federal Regulations, 2014 CFR
2014-01-01
... radiation from an ISFSI or MRS. 72.104 Section 72.104 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED... materials in effluents and direct radiation from an ISFSI or MRS. (a) During normal operations and... radioactive materials, radon and its decay products excepted, to the general environment, (2) Direct radiation...
Code of Federal Regulations, 2012 CFR
2012-01-01
... radiation from an ISFSI or MRS. 72.104 Section 72.104 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED... materials in effluents and direct radiation from an ISFSI or MRS. (a) During normal operations and... radioactive materials, radon and its decay products excepted, to the general environment, (2) Direct radiation...
Code of Federal Regulations, 2013 CFR
2013-01-01
... radiation from an ISFSI or MRS. 72.104 Section 72.104 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED... materials in effluents and direct radiation from an ISFSI or MRS. (a) During normal operations and... radioactive materials, radon and its decay products excepted, to the general environment, (2) Direct radiation...
Idilman, Ilkay S; Keskin, Onur; Celik, Azim; Savas, Berna; Elhan, Atilla Halil; Idilman, Ramazan; Karcaaltincaba, Musturay
2016-03-01
Many imaging methods have been defined for quantification of hepatic steatosis in non-alcoholic fatty liver disease (NAFLD). However, studies comparing the efficiency of magnetic resonance imaging-proton density fat fraction (MRI-PDFF), magnetic resonance spectroscopy (MRS), and liver histology for quantification of liver fat content are limited. To compare the efficiency of MRI-PDFF and MRS in the quantification of liver fat content in individuals with NAFLD. A total of 19 NAFLD patients underwent MRI-PDFF, MRS, and liver biopsy for quantification of liver fat content. The MR examinations were performed on a 1.5 HDx MRI system. The MRI protocol included T1-independent volumetric multi-echo gradient-echo imaging with T2* correction and spectral fat modeling and MRS with STEAM technique. A close correlation was observed between liver MRI-PDFF- and histology- determined steatosis (r = 0.743, P < 0.001) and between liver MRS- and histology-determined steatosis (r = 0.712, P < 0.001), with no superiority between them (ƶ = 0.19, P = 0.849). For quantification of hepatic steatosis, a high correlation was observed between the two MRI methods (r = 0.986, P < 0.001). MRI-PDFF and MRS accurately differentiated moderate/severe steatosis from mild/no hepatic steatosis (P = 0.007 and 0.013, respectively), with no superiority between them (AUCMRI-PDFF = 0.881 ± 0.0856 versus AUCMRS = 0.857 ± 0.0924, P = 0.461). Both MRI-PDFF and MRS can be used for accurate quantification of hepatic steatosis. © The Foundation Acta Radiologica 2015.
Jelen, Luke A; King, Sinead; Mullins, Paul G; Stone, James M
2018-05-01
Abnormalities of the glutamate system are increasingly implicated in schizophrenia but their exact nature remains unknown. Proton magnetic resonance spectroscopy ( 1 H-MRS), while fundamental in revealing glutamatergic alterations in schizophrenia, has, until recently, been significantly limited and thought to only provide static measures. Functional magnetic resonance spectroscopy (fMRS), which uses sequential scans for dynamic measurement of a range of brain metabolites in activated brain areas, has lately been applied to a variety of task or stimulus conditions, producing interesting insights into neurometabolite responses to neural activation. Here, we summarise the existing 1 H-MRS studies of brain glutamate in schizophrenia. We then present a comprehensive review of research studies that have utilised fMRS, and lastly consider how fMRS methods might further the understanding of glutamatergic abnormalities in schizophrenia.
10 CFR 72.98 - Identifying regions around an ISFSI or MRS site.
Code of Federal Regulations, 2014 CFR
2014-01-01
... regional extent of external phenomena, man-made or natural, that are used as a basis for the design of the ISFSI or MRS must be identified. (b) The potential regional impact due to the construction, operation or decommissioning of the ISFSI or MRS must be identified. The extent of regional impacts must be determined on the...
10 CFR 72.98 - Identifying regions around an ISFSI or MRS site.
Code of Federal Regulations, 2013 CFR
2013-01-01
... regional extent of external phenomena, man-made or natural, that are used as a basis for the design of the ISFSI or MRS must be identified. (b) The potential regional impact due to the construction, operation or decommissioning of the ISFSI or MRS must be identified. The extent of regional impacts must be determined on the...
10 CFR 72.98 - Identifying regions around an ISFSI or MRS site.
Code of Federal Regulations, 2010 CFR
2010-01-01
... regional extent of external phenomena, man-made or natural, that are used as a basis for the design of the ISFSI or MRS must be identified. (b) The potential regional impact due to the construction, operation or decommissioning of the ISFSI or MRS must be identified. The extent of regional impacts must be determined on the...
Materials & Engineering: Propelling Innovation MRS Bulletin Special Issue Session
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rao, Gopal
Materials enable engineering; and, engineering in turn depends on materials to transform design concepts and equations into physical entities. This relationship continues to grow with expanding societal demand for new products and processes. MRS Bulletin, a publication of the Materials Research Society (MRS) and Cambridge University Press, planned a special issue for December 2015 on Materials and Engineering: Propelling Innovation. This special issue of MRS Bulletin captured the unique relationship between materials and engineering, which are closely intertwined. A special half day session at the 2015 MRS Fall Meeting in Boston captured this discussion through presentations by high level expertsmore » followed by a panel discussion on what it takes to translate materials discoveries into products to benefit society. The Special Session included presentations by experts who are practitioners in materials as well as engineering applications, followed by a panel discussion. Participants discussed state-of-the-art in materials applications in engineering, as well as how engineering needs have pushed materials developments, as also reflected in the 20 or so articles published in the special issue of MRS Bulletin. As expected, the discussions spanned the broad spectrum of materials and provided very strong interdisciplinary interactions and discussions by participants and presenters.« less
Glutamate and Glutamine: A Review of In Vivo MRS in the Human Brain
Ramadan, Saadallah; Lin, Alexander; Stanwell, Peter
2013-01-01
Our understanding of the roles that the amino acids glutamate (Glu) and glutamine (Gln) play in the mammalian central nervous system has increased rapidly in recent times. Many conditions are known to exhibit a disturbance in Glu-Gln equilibrium and the exact relationship between these changed conditions and these amino acids are not fully understood. This has led to increased interest in Glu/Gln quantitation in the human brain in an array of conditions (e.g. mental illness, tumor, neuro-degeneration) as well as in normal brain function. Accordingly, this review has been undertaken to describe the increasing number of in vivo techniques available to study Glu and Gln separately, or pooled as ‘Glx’. The present range of magnetic resonance spectroscopy (MRS) methods used to assess Glu and Gln, vary in approach, complexity and outcome, thus the focus of this review is on a description of MRS acquisition approaches, and an indication of relative utility of each technique rather than brain pathologies associated to Glu and/or Gln perturbation. Consequently, this review focuses particularly on (1) one-dimensional (1D) 1H MRS, (2) two-dimensional (2D) 1H MRS, and (3) 1D 13C MRS techniques. PMID:24123328
Magnetic resonance spectroscopy of the human brain.
Ross, B; Bluml, S
2001-04-01
Magnetic resonance (MR; synonymous with NMR = nuclear magnetic resonance) is a universal physical technique best known for non-invasive detection and anatomical mapping of water protons (H). MR-spectroscopy (MRS) records protons from tissue chemicals other than water, intrinsic phosphorus containing metabolites, sodium, potassium, carbon, nitrogen, and fluorine. MRS is therefore an imaging technique with the potential to record human and animal biochemistry in vivo. As a result of wide availability of MRI equipment in research laboratories and hospitals, MRS is a serious competitor with PET to define normal body composition and its perturbation by pharmacological and pathological events. This article describes practical aspects of in vivo MRS with particular emphasis on the brain, where novel metabolites have been described. A survey of these new aspects of neurochemistry emphasize their practical utility as neuronal and axonal markers, measures of energy status, membrane constituents, and osmolytes, as well as some xenobiotics, such as alcohol. The concept of multinuclear in vivo MRS is illustrated by diagnosis and therapeutic monitoring of several human brain disorders. Although these methods are currently most frequently encountered in human studies, as well as with transgenic and knockout mouse models, MRS adds a new dimension to anatomic and histopathologic descriptions. Copyright 2001 Wiley-Liss, Inc.
Carlson, Dustin A; Crowell, Michael D; Kimmel, Jessica N; Patel, Amit; Gyawali, C Prakash; Hinchcliff, Monique; Griffing, W Leroy; Pandolfino, John E; Vela, Marcelo F
2016-10-01
We assessed peristaltic reserve using multiple rapid swallows (MRS) during esophageal high-resolution manometry (HRM) of 111 patients with systemic sclerosis (89 women; ages, 42-64 y). We performed a retrospective analysis of HRM studies that included MRS in patients with systemic sclerosis, performed at 2 tertiary referral centers, and compared data with those from 18 healthy volunteers (controls). HRM findings were analyzed according to the Chicago Classification to provide an esophageal motility diagnosis. Response to MRS was evaluated for the presence of contraction and for augmentation, defined as the distal contractile integral after MRS greater than the median distal contractile integral of 10 supine swallows. Esophageal motility diagnoses included 41% with absent contractility, 31% with normal motility, 23% with ineffective esophageal motility, and 5% that met the criteria for other esophageal motility disorders. Contraction (37%) and peristaltic augmentation (18%) after MRS were observed less frequently in patients with systemic sclerosis than in controls (83% and 100%, respectively). Impaired peristaltic reserve, as assessed with MRS during HRM, is therefore the most common esophageal motility finding among patients with systemic sclerosis. Copyright © 2016 AGA Institute. Published by Elsevier Inc. All rights reserved.
Yang, Guang; Nawaz, Tahir; Barrick, Thomas R; Howe, Franklyn A; Slabaugh, Greg
2015-12-01
Many approaches have been considered for automatic grading of brain tumors by means of pattern recognition with magnetic resonance spectroscopy (MRS). Providing an improved technique which can assist clinicians in accurately identifying brain tumor grades is our main objective. The proposed technique, which is based on the discrete wavelet transform (DWT) of whole-spectral or subspectral information of key metabolites, combined with unsupervised learning, inspects the separability of the extracted wavelet features from the MRS signal to aid the clustering. In total, we included 134 short echo time single voxel MRS spectra (SV MRS) in our study that cover normal controls, low grade and high grade tumors. The combination of DWT-based whole-spectral or subspectral analysis and unsupervised clustering achieved an overall clustering accuracy of 94.8% and a balanced error rate of 7.8%. To the best of our knowledge, it is the first study using DWT combined with unsupervised learning to cluster brain SV MRS. Instead of dimensionality reduction on SV MRS or feature selection using model fitting, our study provides an alternative method of extracting features to obtain promising clustering results.
Gambitta, Pietro; Armellino, Antonio; Forti, Edoardo; Vertemati, Maurizio; Colombo, Paola Enrica; Aseni, Paolo
2014-07-14
To investigate the impact of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) in association with a multidisciplinary team evaluation for the detection of gastrointestinal malignancies. A cohort of 1019 patients with suspected malignant lesions adjacent to the gastrointestinal tract received EUS-FNA after a standardized multidisciplinary team evaluation (MTE) and were divided into 4 groups according to their specific malignant risk score (MRS). Patients with a MRS of 0 (without detectable risk of malignancy) received only EUS without FNA. For patients with a MRS score ranging from 1 (low risk) - through 2 (intermediate risk) - to 3 (high risk), EUS-FNA cytology of the lesion was planned for a different time and was prioritized for those patients at higher risk for cancer. The accuracy, efficiency and quality assessment for the early detection of patients with potentially curable malignant lesions were evaluated for the whole cohort and in the different classes of MRSs. The time to definitive cytological diagnosis (TDCD), accuracy, sensitivity, specificity, positive and negative predictive values, and the rate of inconclusive tests were calculated for all patients and for each MRS group. A total of 1019 patients with suspected malignant lesions were evaluated by EUS-FNA. In 515 patients of 616 with true malignant lesions the tumor was diagnosed by EUS-FNA; 421 patients with resectable lesions received early surgical treatment, and 94 patients received chemo-radiotherapy. The overall diagnostic accuracy for the 1019 lesions in which a final diagnosis was obtained by EUS-FNA was 0.95. When patients were stratified by MTE into 4 classes of MRSs, a higher rate of patients in the group with higher cancer risk (MRS-3) received early treatment and EUS-FNA showed the highest level of accuracy (1.0). TDCD was also shorter in the MRS-3 group. The number of patients who received surgical treatment or chemo-radiotherapy was significantly higher in the MRS-3 patient group (36.3% in MRS-3, 10.7% in MRS-2, and 3.5% in MRS-1). EUS-FNA can effectively detect a curable malignant lesions at an earlier time and at a higher rate in patients with a higher cancer risk that were evaluated using MTE.
1H Magnetic Resonance Spectroscopy of live human sperm
Calvert, S J; Paley, M N; Pacey, A A
2017-01-01
Abstract STUDY QUESTION Can 1H Magnetic Resonance Spectroscopy (MRS) be used to obtain information about the molecules and metabolites in live human spermatozoa? SUMMARY ANSWER Percoll-based density gradient centrifugation (DGC) followed by a further two washing steps, yielded enough sperm with minimal contamination (<0.01%) from seminal fluid to permit effective MRS which detected significant differences (P < 0.05) in the choline/glycerophosphocholine (GPC), lipid and lactate regions of the 1H MRS spectrum between sperm in the pellet and those from the 40%/80% interface. WHAT IS KNOWN ALREADY Current methods to examine sperm are either limited in their value (e.g. semen analysis) or are destructive (e.g. immunohistochemistry, sperm DNA testing). A few studies have previously used MRS to examine sperm, but these have either looked at seminal plasma from men with different ejaculate qualities or at the molecules present in pooled samples of lyophilized sperm. STUDY DESIGN, SAMPLES/MATERIALS, METHODS Sperm suspended in phosphate buffered saline (PBS) at 37°C were examined by 1H MRS scanning using a 1H excitation-sculpting solvent suppression sequence after recovery from fresh ejaculates by one of three different methods: (i) simple centrifugation; (ii) DGC with one wash; or (iii) DGC with two washes. In the case of DGC, sperm were collected both from the pellet (‘80%’ sperm) and the 40/80 interface (‘40%’ sperm). Spectrum processing was carried out using custom Matlab scripts to determine; the degree of seminal plasma/Percoll contamination, the minimum sperm concentration for 1H MRS detection and differences between the 1H MRS spectra of ‘40%’ and ‘80%’ sperm. MAIN RESULTS AND THE ROLE OF CHANCE DGC with two washes minimized the 1H MRS peak intensity for both seminal plasma and Percoll/PBS solution contamination while retaining sperm specific peaks. For the MRS scanner used in this study, the minimum sperm concentration required to produce a choline/GPC 1H MRS peak greater than 3:1 signal to noise ratio (SNR) was estimated at ~3 × 106/ml. The choline/GPC and lactate/lipid regions of the 1H spectrum were significantly different by two-way ANOVA analysis (P < 0.0001; n = 20). ROC curve analysis of these region showed significant ability to distinguish between the two sperm populations: choline/GPC ROC AUC = 0.65–0.67, lactate/lipid ROC AUC = 0.86–0.87. LIMITATIONS, REASONS FOR CAUTION Only 3–4 semen samples were used to assess the efficacy of each sperm washing protocol that were examined. The estimated minimum sperm concentration required for MRS is specific to the hardware used in our study and may be different in other spectrometers. Spectrum binning is a low resolution analysis method that sums MRS peaks within a chemical shift range. This can obscure the identity of which metabolite(s) are responsible for differences between sperm populations. Further work is required to determine the relative contribution of somatic cells to the MRS spectrum from the ‘40%’ and ‘80%’ sperm. WIDER IMPLICATIONS OF THE FINDINGS 1H MRS can provide information about the molecules present in live human sperm and may therefore permit the study of the underlying functional biology or metabolomics of live sperm. Given the relatively low concentration of sperm required to obtain a suitable MRS signal (~3 × 106/ml), this could be carried out on sperm from men with oligo-, astheno- or teratozoospermia. This may lead to the development of new diagnostic tests or ultimately novel treatments for male factor infertility. STUDY FUNDING AND COMPETING INTEREST(S) This work was supported by the Medical Research Council Grant MR/M010473/1. The authors declare no conflicts of interest. PMID:28431025
1H Magnetic Resonance Spectroscopy of live human sperm.
Reynolds, S; Calvert, S J; Paley, M N; Pacey, A A
2017-07-01
Can 1H Magnetic Resonance Spectroscopy (MRS) be used to obtain information about the molecules and metabolites in live human spermatozoa? Percoll-based density gradient centrifugation (DGC) followed by a further two washing steps, yielded enough sperm with minimal contamination (<0.01%) from seminal fluid to permit effective MRS which detected significant differences (P < 0.05) in the choline/glycerophosphocholine (GPC), lipid and lactate regions of the 1H MRS spectrum between sperm in the pellet and those from the 40%/80% interface. Current methods to examine sperm are either limited in their value (e.g. semen analysis) or are destructive (e.g. immunohistochemistry, sperm DNA testing). A few studies have previously used MRS to examine sperm, but these have either looked at seminal plasma from men with different ejaculate qualities or at the molecules present in pooled samples of lyophilized sperm. Sperm suspended in phosphate buffered saline (PBS) at 37°C were examined by 1H MRS scanning using a 1H excitation-sculpting solvent suppression sequence after recovery from fresh ejaculates by one of three different methods: (i) simple centrifugation; (ii) DGC with one wash; or (iii) DGC with two washes. In the case of DGC, sperm were collected both from the pellet ('80%' sperm) and the 40/80 interface ('40%' sperm). Spectrum processing was carried out using custom Matlab scripts to determine; the degree of seminal plasma/Percoll contamination, the minimum sperm concentration for 1H MRS detection and differences between the 1H MRS spectra of '40%' and '80%' sperm. DGC with two washes minimized the 1H MRS peak intensity for both seminal plasma and Percoll/PBS solution contamination while retaining sperm specific peaks. For the MRS scanner used in this study, the minimum sperm concentration required to produce a choline/GPC 1H MRS peak greater than 3:1 signal to noise ratio (SNR) was estimated at ~3 × 106/ml. The choline/GPC and lactate/lipid regions of the 1H spectrum were significantly different by two-way ANOVA analysis (P < 0.0001; n = 20). ROC curve analysis of these region showed significant ability to distinguish between the two sperm populations: choline/GPC ROC AUC = 0.65-0.67, lactate/lipid ROC AUC = 0.86-0.87. Only 3-4 semen samples were used to assess the efficacy of each sperm washing protocol that were examined. The estimated minimum sperm concentration required for MRS is specific to the hardware used in our study and may be different in other spectrometers. Spectrum binning is a low resolution analysis method that sums MRS peaks within a chemical shift range. This can obscure the identity of which metabolite(s) are responsible for differences between sperm populations. Further work is required to determine the relative contribution of somatic cells to the MRS spectrum from the '40%' and '80%' sperm. 1H MRS can provide information about the molecules present in live human sperm and may therefore permit the study of the underlying functional biology or metabolomics of live sperm. Given the relatively low concentration of sperm required to obtain a suitable MRS signal (~3 × 106/ml), this could be carried out on sperm from men with oligo-, astheno- or teratozoospermia. This may lead to the development of new diagnostic tests or ultimately novel treatments for male factor infertility. This work was supported by the Medical Research Council Grant MR/M010473/1. The authors declare no conflicts of interest. © The Author 2016. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved.
Medical Representatives' Intention to Use Information Technology in Pharmaceutical Marketing.
Kwak, Eun-Seon; Chang, Hyejung
2016-10-01
Electronic detailing (e-detailing), the use of electronic devices to facilitate sales presentations to physicians, has been adopted and expanded in the pharmaceutical industry. To maximize the potential outcome of e-detailing, it is important to understand medical representatives (MRs)' behavior and attitude to e-detailing. This study investigates how information technology devices such as laptop computers and tablet PCs are utilized in pharmaceutical marketing, and it analyzes the factors influencing MRs' intention to use devices. This study has adopted and modified the theory of Roger's diffusion of innovation model and the technology acceptance model. To test the model empirically, a questionnaire survey was conducted with 221 MRs who were working in three multinational or eleven domestic pharmaceutical companies in Korea. Overall, 28% and 35% of MRs experienced using laptop computers and tablet PCs in pharmaceutical marketing, respectively. However, the rates were different across different groups of MRs, categorized by age, education level, position, and career. The results showed that MRs' intention to use information technology devices was significantly influenced by perceived usefulness in general. Perceived ease of use, organizational and individual innovativeness, and several MR characteristics were also found to have significant impacts. This study provides timely information about e-detailing devices to marketing managers and policy makers in the pharmaceutical industry for successful marketing strategy development by understanding the needs of MRs' intention to use information technology. Further in-depth study should be conducted to understand obstacles and limitations and to improve the strategies for better marketing tools.
Brain glutamate in medication-free depressed patients: a proton MRS study at 7 Tesla.
Godlewska, Beata R; Masaki, Charles; Sharpley, Ann L; Cowen, Philip J; Emir, Uzay E
2017-12-11
The possible role of glutamate in the pathophysiology and treatment of depression is of intense current interest. Proton magnetic resonance spectroscopy (MRS) enables the detection of glutamate in the living human brain and meta-analyses of previous MRS studies in depressed patients have suggested that glutamate levels are decreased in anterior brain regions. Nevertheless, at conventional magnetic field strengths [1.5-3 Tesla (T)], it is difficult to separate glutamate from its metabolite and precursor, glutamine, with the two often being measured together as Glx. In contrast, MRS at 7 T allows clear spectral resolution of glutamate and glutamine. We studied 55 un-medicated depressed patients and 50 healthy controls who underwent MRS scanning at 7 T with voxels placed in anterior cingulate cortex, occipital cortex and putamen (PUT). Neurometabolites were calculated using the unsuppressed water signal as a reference. Compared with controls, depressed patients showed no significant difference in glutamate in any of the three voxels studied; however, glutamine concentrations in the patients were elevated by about 12% in the PUT (p < 0.001). The increase in glutamine in PUT is of interest in view of the postulated role of the basal ganglia in the neuropsychology of depression and is consistent with elevated activity in the descending cortical glutamatergic innervation to the PUT. The basal ganglia have rarely been the subject of MRS investigations in depressed patients and further MRS studies of these structures in depression are warranted.
Melanoma recognition framework based on expert definition of ABCD for dermoscopic images.
Abbas, Qaisar; Emre Celebi, M; Garcia, Irene Fondón; Ahmad, Waqar
2013-02-01
Melanoma Recognition based on clinical ABCD rule is widely used for clinical diagnosis of pigmented skin lesions in dermoscopy images. However, the current computer-aided diagnostic (CAD) systems for classification between malignant and nevus lesions using the ABCD criteria are imperfect due to use of ineffective computerized techniques. In this study, a novel melanoma recognition system (MRS) is presented by focusing more on extracting features from the lesions using ABCD criteria. The complete MRS system consists of the following six major steps: transformation to the CIEL*a*b* color space, preprocessing to enhance the tumor region, black-frame and hair artifacts removal, tumor-area segmentation, quantification of feature using ABCD criteria and normalization, and finally feature selection and classification. The MRS system for melanoma-nevus lesions is tested on a total of 120 dermoscopic images. To test the performance of the MRS diagnostic classifier, the area under the receiver operating characteristics curve (AUC) is utilized. The proposed classifier achieved a sensitivity of 88.2%, specificity of 91.3%, and AUC of 0.880. The experimental results show that the proposed MRS system can accurately distinguish between malignant and benign lesions. The MRS technique is fully automatic and can easily integrate to an existing CAD system. To increase the classification accuracy of MRS, the CASH pattern recognition technique, visual inspection of dermatologist, contextual information from the patients, and the histopathological tests can be included to investigate the impact with this system. © 2012 John Wiley & Sons A/S.
Valkovič, Ladislav; Chmelík, Marek; Ukropcová, Barbara; Heckmann, Thomas; Bogner, Wolfgang; Frollo, Ivan; Tschan, Harald; Krebs, Michael; Bachl, Norbert; Ukropec, Jozef; Trattnig, Siegfried; Krššák, Martin
2016-01-01
Defects in skeletal muscle energy metabolism are indicative of systemic disorders such as obesity or type 2 diabetes. Phosphorus magnetic resonance spectroscopy (31P-MRS), in particularly dynamic 31P-MRS, provides a powerful tool for the non-invasive investigation of muscular oxidative metabolism. The increase in spectral and temporal resolution of 31P-MRS at ultra high fields (i.e., 7T) uncovers new potential for previously implemented techniques, e.g., saturation transfer (ST) or highly resolved static spectra. In this study, we aimed to investigate the differences in muscle metabolism between overweight-to-obese sedentary (Ob/Sed) and lean active (L/Ac) individuals through dynamic, static, and ST 31P-MRS at 7T. In addition, as the dynamic 31P-MRS requires a complex setup and patient exercise, our aim was to identify an alternative technique that might provide a biomarker of oxidative metabolism. The Ob/Sed group exhibited lower mitochondrial capacity, and, in addition, static 31P-MRS also revealed differences in the Pi-to-ATP exchange flux, the alkaline Pi-pool, and glycero-phosphocholine concentrations between the groups. In addition to these differences, we have identified correlations between dynamically measured oxidative flux and static concentrations of the alkaline Pi-pool and glycero-phosphocholine, suggesting the possibility of using high spectral resolution 31P-MRS data, acquired at rest, as a marker of oxidative metabolism. PMID:26838588
Elliott, Katie L; Kandiah, Jay; Walroth, Todd A
2017-07-01
Formal nutrition training in medical schools and residencies is lacking and needed. Registered dietitians (RDs) are formally trained in nutrition support and considered experts in the nutrition field. Our purpose was to examine prescribing and recommending discrepancies of parenteral nutrition macronutrients between medical residents (MRs) and RDs and compare results with the ASPEN clinical care guidelines. We also looked at discrepancies among obese patients, due to their increased risk of mortality. The primary end point of this retrospective review was discrepancies in nonprotein calories (NPCs) and grams of protein (PRO) between MRs and RDs. The secondary end point was discrepancies in NPCs and PRO between MRs and RDs among patients stratified by body mass index category. MRs prescribed 300 NPCs more versus RDs ( P < .001). When compared with RDs, MRs prescribed fewer NPCs for underweight patients and more for obese patients ( P < .001). The same analysis found that the PRO discrepancies significantly varied by body mass index classification as well ( P = .022). When these results were compared with the ASPEN clinical care guidelines, RDs adhered closer to the guidelines than did MRs in terms of permissive underfeeding of obese patients. It is widely accepted that MRs are in need of increased formal training, and the results of our study confirm this need and suggest a short-term solution of increasing order-writing privileges for the RD. RDs with this privilege may adhere more closely to clinical care guidelines and therefore increase patient safety.
U.S. Army Medical Department Journal, October-December 2005
2005-12-01
body image. The BOSS program has conducted ongoing video game Soldiers of the 421st were 100% professional, tournaments and a local summer jam in the...community. courteous, and caring. They quickly established rapport This summer was highlighted by the theater show "Beyond and put students at ease while...Wallace (((7th from left), B.F. Stout (8th from left), Dr Stewart (9th from left), Mrs. Stewart (next to husband), Robert Hausman (4th from right), BG
Challenges in the Assessment and Treatment of Health Anxiety: The Case of Mrs. A.
ERIC Educational Resources Information Center
McCabe, Randi E.; Antony, Martin M.
2004-01-01
Health anxiety can present a challenge for clinicians, both from the perspective of assigning a "DSM-IV" diagnosis and in developing an appropriate treatment plan. The case of Mrs. A. illustrates some of the complexities that arise in the diagnosis and treatment of health anxiety. Mrs. A. is a 60-year-old retired teacher who presented to a…
Kemp, Graham J; Brindle, Kevin M
2012-08-01
Magnetic resonance spectroscopy (MRS) methods offer a potentially valuable window into cellular metabolism. Measurement of flux between inorganic phosphate (Pi) and ATP using (31)P MRS magnetization transfer has been used in resting muscle to assess what is claimed to be mitochondrial ATP synthesis and has been particularly popular in the study of insulin effects and insulin resistance. However, the measured Pi→ATP flux in resting skeletal muscle is far higher than the true rate of oxidative ATP synthesis, being dominated by a glycolytically mediated Pi↔ATP exchange reaction that is unrelated to mitochondrial function. Furthermore, even if measured accurately, the ATP production rate in resting muscle has no simple relationship to mitochondrial capacity as measured either ex vivo or in vivo. We summarize the published measurements of Pi→ATP flux, concentrating on work relevant to diabetes and insulin, relate it to current understanding of the physiology of mitochondrial ATP synthesis and glycolytic Pi↔ATP exchange, and discuss some possible implications of recently reported correlations between Pi→ATP flux and other physiological measures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1991-09-01
Radioactive waste is mounting at U.S. nuclear power plants at a rate of more than 2,000 metric tons a year. Pursuant to statute and anticipating that a geologic repository would be available in 1998, the Department of Energy (DOE) entered into disposal contracts with nuclear utilities. Now, however, DOE does not expect the repository to be ready before 2010. For this reason, DOE does not want to develop a facility for monitored retrievable storage (MRS) by 1998. This book is concerned about how best to store the waste until a repository is available, congressional requesters asked GAO to review themore » alternatives of continued storage at utilities' reactor sites or transferring waste to an MRS facility, GAO assessed the likelihood of an MRSA facility operating by 1998, legal implications if DOE is not able to take delivery of wastes in 1998, propriety of using the Nuclear Waste Fund-from which DOE's waste program costs are paid-to pay utilities for on-site storage capacity added after 1998, ability of utilities to store their waste on-site until a repository is operating, and relative costs and safety of the two storage alternatives.« less
Navigating the clinical trial pathway: Conception, design, execution, and results dissemination.
Sampalis, John S; Watson, Joanne; Boukas, Stella; Boukas, Marianna; Harvey, Natalie; Machado, Sanjay; Bordeleau, Michel; Rampakakis, Emmanouil
2017-03-01
Dr Sampalis is founder, Chief Executive Officer, and Chief Scientific Officer of JSS Medical Research Inc, founded in 1997. He is a tenured professor of Surgery and Epidemiology & Biostatistics of McGill University, the University of Montreal and University of Laval. Recognized as a leading clinical epidemiologist and one of the top trauma researchers in Canada, he possesses extensive expertise in health services research, clinical trials, and offers services as a Research and Epidemiological Consultant for numerous pharmaceutical companies, hospitals and government organizations and agencies. Mrs. Watson holds a M.Sc. in Pharmacology from Dalhousie University, and a B.Sc. from the University of Western Ontario. Her experience extends to all facets of the CRO business, and multiple therapeutic areas. She co-founded, in 1992, Integrated Research Inc, a full-service contract research organization, and served as its President and Chief Executive Officer, until merging with JSS Medical Research Inc in 2014. Mrs. Watson currently holds the position of Chief Business Officer, and is head of the business development team. Mrs. Boukas has been working with the JSS Medical Research team since its inception in the 1990s. She holds a B.A. in Psychology from McGill University with training in Epidemiology and Biostatistics, and is certified by the Society of Clinical Research Associates (SOCRA) as a Certified Clinical Research Professional (CCRP). She has over 25 years' of experience in medical research management. Currently Chief Operations Officer, Mrs. Boukas has been essential in structuring and implementing programs at JSS Medical Research Inc to facilitate project management, site recruitment, data capture and study tracking. Mrs. Boukas holds a B.A. from McGill University, a Certificate in Technical Communications from Concordia University and has received compliance training from SNC Lavalin Pharma (SLP) and SOCRA. She has over twenty-five years' experience in research. Joining JSS Medical Research Inc in 1998, she currently holds the position of Executive Director of Quality Assurance (QA) where she developed and maintains the QA Program since 2004. The QA Program supports clinical studies conducted in Canada, Latin America, India and Europe. Mrs. Harvey holds a B.Sc. in Biochemistry from the Université du Québec à Montréal and a M.Sc. in Biology from McGill University. With 20 years' experience in the pharmaceutical industry, she has held positions in both Commercial and Medical departments. Mrs. Harvey currently holds the position of Director, Clinical Operations at JSS Medical Research Inc, functionally and operationally overseeing a team of project and data managers in the development and implementation of clinical studies. Dr Machado obtained his medical degree from the University of Pune, India. He has over 20 years' experience in multinational pharmaceutical, CRO, Bioequivalence & Phase I and Site Management Organizations, working in several therapeutic areas and phase of studies. As a founder of Venn Life Sciences, Dr Machado served as Chief Operating Officer, until joining JSS Medical Research Inc in 2011, where he is currently Vice-President, Global Operations & Integration. In addition to overseeing global operations, he is responsible for global expansion and integration of JSS Medical Research Inc through acquisitions and mergers. Mr. Bordeleau holds a B.Sc. in Biochemistry from the University of Guelph and an MBA from HEC Montreal. He has over 20 years' experience in the pharmaceutical industry, including laboratory and IT research, healthcare marketing support, and IT team management. As Global Director of information Technology at JSS Medical Research Inc, Mr. Bordeleau leads a team of programmers as well as network, database and system administrators who specialize in developing, maintaining, and most importantly, improving, key software, clinical systems, infrastructure, and business processes. Dr Rampakakis received his Ph.D. from the Department of Biochemistry from McGill University, and obtained post-doctoral training, also at McGill, in Pharmacoepidemiology. With over 15 years' experience in scientific research, he has contributed in the conception, design, analysis and interpretation of several large scale, national and international, registration and observational studies. He currently holds the position of Vice President of Scientific Affairs at JSS Medical Research Inc, overseeing a team of biostatisticians, epidemiologists, physicians, medical writers, and health economists. Copyright © 2016 Elsevier Inc. All rights reserved.
Forces Mobilization Model (FORCEMOB): Unclassified Training Tutorial
2015-08-01
I N S T I T U T E F O R D E F E N S E A N A L Y S E S Forces Mobilization Model (FORCEMOB): Unclassified Training Tutorial James S. Thomason...Graham for review of this document and Mrs. Amberlee Mabe -Stanberry for editing and production assistance. Copyright Notice © 2015 Institute for...N S E A N A L Y S E S Forces Mobilization Model (FORCEMOB): Unclassified Training Tutorial James S. Thomason, Project Leader Robert J. Atwell
Quintana, Gabriel; Gerbino, Esteban; Gómez-Zavaglia, Andrea
2017-01-01
Okara is a nutritionally valuable by-product produced in large quantities as result of soymilk elaboration. This work proposes its use as both culture and dehydration medium during freeze-drying, spray-drying, and storage of Lactobacillus plantarum CIDCA 83114. Whole and defatted okara were employed as culture media for L. plantarum CIDCA 83114. The growth kinetics were followed by plate counting and compared with those of bacteria grown in MRS broth (control). No significant differences in plate counting were observed in the three media. The fatty acid composition of bacteria grown in whole and defatted okara showed a noticeable increase in the unsaturated/saturated (U/S) fatty acid ratio, with regard to bacteria grown in MRS. This change was mainly due to the increase in polyunsaturated fatty acids, namely C18:2. For dehydration assays, cultures in the stationary phase were neutralized and freeze-dried (with or without the addition of 250 mM sucrose) or spray-dried. Bacteria were plate counted immediately after freeze-drying or spray-drying and during storage at 4°C for 90 days. Freeze-drying in whole okara conducted to the highest bacterial recovery. Regarding storage, spray-dried bacteria previously grown in whole and defatted okara showed higher plate counts than those grown in MRS. On the contrary, freeze-dried bacteria previously grown in all the three culture media were those with the lowest plate counts. The addition of sucrose to the dehydration media improved their recovery. The higher recovery of microorganisms grown in okara after freeze-drying and spray-drying processes and during storage was ascribed to both the presence of fiber and proteins in the dehydration media, and the increase in U/S fatty acids ratio in bacterial membranes. The obtained results support for the first time the use of okara as an innovative matrix to deliver L. plantarum . Considering that okara is an agro-waste obtained in large quantities, these results represent an innovative strategy to add it value, providing a symbiotic ingredient with promising industrial applications in the development of novel functional foods and feeds.
Quintana, Gabriel; Gerbino, Esteban; Gómez-Zavaglia, Andrea
2017-01-01
Okara is a nutritionally valuable by-product produced in large quantities as result of soymilk elaboration. This work proposes its use as both culture and dehydration medium during freeze-drying, spray-drying, and storage of Lactobacillus plantarum CIDCA 83114. Whole and defatted okara were employed as culture media for L. plantarum CIDCA 83114. The growth kinetics were followed by plate counting and compared with those of bacteria grown in MRS broth (control). No significant differences in plate counting were observed in the three media. The fatty acid composition of bacteria grown in whole and defatted okara showed a noticeable increase in the unsaturated/saturated (U/S) fatty acid ratio, with regard to bacteria grown in MRS. This change was mainly due to the increase in polyunsaturated fatty acids, namely C18:2. For dehydration assays, cultures in the stationary phase were neutralized and freeze-dried (with or without the addition of 250 mM sucrose) or spray-dried. Bacteria were plate counted immediately after freeze-drying or spray-drying and during storage at 4°C for 90 days. Freeze-drying in whole okara conducted to the highest bacterial recovery. Regarding storage, spray-dried bacteria previously grown in whole and defatted okara showed higher plate counts than those grown in MRS. On the contrary, freeze-dried bacteria previously grown in all the three culture media were those with the lowest plate counts. The addition of sucrose to the dehydration media improved their recovery. The higher recovery of microorganisms grown in okara after freeze-drying and spray-drying processes and during storage was ascribed to both the presence of fiber and proteins in the dehydration media, and the increase in U/S fatty acids ratio in bacterial membranes. The obtained results support for the first time the use of okara as an innovative matrix to deliver L. plantarum. Considering that okara is an agro-waste obtained in large quantities, these results represent an innovative strategy to add it value, providing a symbiotic ingredient with promising industrial applications in the development of novel functional foods and feeds. PMID:28446905
Shah, Sachin D.; Kress, Wade H.; Legchenko, Anatoly
2007-01-01
The U.S. Geological Survey, in cooperation with the Texas Water Development Board, used surface geophysical methods at the Texas A&M University Brazos River Hydrologic Field Research Site near College Station, Texas, in a pilot study, to characterize the hydrostratigraphic properties of the Brazos River alluvium aquifer and determine the effectiveness of the methods to aid in generating an improved ground-water availability model. Three non-invasive surface geophysical methods were used to characterize the electrical stratigraphy and hydraulic properties and to interpret the hydrostratigraphy of the Brazos River alluvium aquifer. Two methods, time-domain electromagnetic (TDEM) soundings and two-dimensional direct-current (2D-DC) resistivity imaging, were used to define the lateral and vertical extent of the Ships clay, the alluvium of the Brazos River alluvium aquifer, and the underlying Yegua Formation. Magnetic resonance sounding (MRS), a recently developed geophysical method, was used to derive estimates of the hydrologic properties including percentage water content and hydraulic conductivity. Results from the geophysics study demonstrated the usefulness of combined TDEM, 2D-DC resistivity, and MRS methods to reduce the need for additional boreholes in areas with data gaps and to provide more accurate information for ground-water availability models. Stratigraphically, the principal finding of this study is the relation between electrical resistivity and the depth and thickness of the subsurface hydrostratigraphic units at the site. TDEM data defined a three-layer electrical stratigraphy corresponding to a conductor-resistor-conductor that represents the hydrostratigraphic units - the Ships clay, the alluvium of the Brazos River alluvium aquifer, and the Yegua Formation. Sharp electrical boundaries occur at about 4 to 6 and 20 to 22 meters below land surface based on the TDEM data and define the geometry of the more resistive Brazos River alluvium aquifer. Variations in resistivity in the alluvium aquifer range from 10 to more than 175 ohm-meters possibly are caused by lateral changes in grain size. Resistivity increases from east to west along a profile away from the Brazos River, which signifies an increase in grain size within the alluvium aquifer and therefore a more productive zone with more abundant water in the aquifer. MRS data can help delineate the subsurface hydrostratigraphy and identify the geometric boundaries of the hydrostratigraphic units by identifying changes in the free water content, transmissivity, and hydraulic conductivity. MRS data indicate that most productive zones of the alluvium aquifer occur between 12 and 25 meters below land surface in the western part of the study area where the hydraulic conductivity can be as high as 250 meters per day. Hydrostratigraphically, individual hydraulic conductivity values derived from MRS were consistent with those from aquifer tests conducted in 1996 in the study area. Average hydraulic conductivity values from the aquifer tests range from about 61 to 80 meters per day, whereas the MRS-derived hydraulic conductivity values range from about 27 to 97 meters per day. Interpreting an interpolated profile of the hydraulic conductivity values and individual values derived from MRS can help describe the hydrostratigraphic framework of an area and constrain ground-water models for better accuracy.
Pennington, Jeffrey W; Ruth, Byron; Italia, Michael J; Miller, Jeffrey; Wrazien, Stacey; Loutrel, Jennifer G; Crenshaw, E Bryan; White, Peter S
2014-01-01
Biomedical researchers share a common challenge of making complex data understandable and accessible as they seek inherent relationships between attributes in disparate data types. Data discovery in this context is limited by a lack of query systems that efficiently show relationships between individual variables, but without the need to navigate underlying data models. We have addressed this need by developing Harvest, an open-source framework of modular components, and using it for the rapid development and deployment of custom data discovery software applications. Harvest incorporates visualizations of highly dimensional data in a web-based interface that promotes rapid exploration and export of any type of biomedical information, without exposing researchers to underlying data models. We evaluated Harvest with two cases: clinical data from pediatric cardiology and demonstration data from the OpenMRS project. Harvest's architecture and public open-source code offer a set of rapid application development tools to build data discovery applications for domain-specific biomedical data repositories. All resources, including the OpenMRS demonstration, can be found at http://harvest.research.chop.edu.
Pennington, Jeffrey W; Ruth, Byron; Italia, Michael J; Miller, Jeffrey; Wrazien, Stacey; Loutrel, Jennifer G; Crenshaw, E Bryan; White, Peter S
2014-01-01
Biomedical researchers share a common challenge of making complex data understandable and accessible as they seek inherent relationships between attributes in disparate data types. Data discovery in this context is limited by a lack of query systems that efficiently show relationships between individual variables, but without the need to navigate underlying data models. We have addressed this need by developing Harvest, an open-source framework of modular components, and using it for the rapid development and deployment of custom data discovery software applications. Harvest incorporates visualizations of highly dimensional data in a web-based interface that promotes rapid exploration and export of any type of biomedical information, without exposing researchers to underlying data models. We evaluated Harvest with two cases: clinical data from pediatric cardiology and demonstration data from the OpenMRS project. Harvest's architecture and public open-source code offer a set of rapid application development tools to build data discovery applications for domain-specific biomedical data repositories. All resources, including the OpenMRS demonstration, can be found at http://harvest.research.chop.edu PMID:24131510
Li, Shizhe; An, Li; Yu, Shao; Ferraris Araneta, Maria; Johnson, Christopher S; Wang, Shumin; Shen, Jun
2016-03-01
Carbon-13 ((13)C) MR spectroscopy (MRS) of the human brain at 7 Tesla (T) may pose patient safety issues due to high radiofrequency (RF) power deposition for proton decoupling. The purpose of present work is to study the feasibility of in vivo (13)C MRS of human brain at 7 T using broadband low RF power proton decoupling. Carboxylic/amide (13)C MRS of human brain by broadband stochastic proton decoupling was demonstrated on a 7 T scanner. RF safety was evaluated using the finite-difference time-domain method. (13)C signal enhancement by nuclear Overhauser effect (NOE) and proton decoupling was evaluated in both phantoms and in vivo. At 7 T, the peak amplitude of carboxylic/amide (13)C signals was increased by a factor of greater than 4 due to the combined effects of NOE and proton decoupling. The 7 T (13)C MRS technique used decoupling power and average transmit power of less than 35 watts (W) and 3.6 W, respectively. In vivo (13)C MRS studies of human brain can be performed at 7 T, well below the RF safety threshold, by detecting carboxylic/amide carbons with broadband stochastic proton decoupling. © 2015 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Bao, Jianfeng; Cui, Xiaohong; Huang, Yuqing; Zhong, Jianhui; Chen, Zhong
2015-08-01
High-resolution 1H magnetic resonance spectroscopy (MRS) is generally inaccessible in red bone marrow (RBM) tissues using conventional MRS techniques. This is because signal from these tissues suffers from severe inhomogeneity in the main static B0 field originated from the intrinsic honeycomb structures in trabecular bone. One way to reduce effects of B0 field inhomogeneity is by using the intermolecular double quantum coherence (iDQC) technique, which has been shown in other systems to obtain signals insensitive to B0 field inhomogeneity. In the present study, we employed an iDQC approach to enhance the spectral resolution of RBM. The feasibility and performance of this method for achieving high resolution MRS was verified by experiments on phantoms and pig vertebral bone samples. Unsaturated fatty acid peaks which overlap in the conventional MRS were well resolved and identified in the iDQC spectrum. Quantitative comparison of fractions of three types of fatty acids was performed between iDQC spectra on the in situ RMB and conventional MRS on the extracted fat from the same RBM. Observations of unsaturated fatty acids with iDQC MRS may provide valuable information and may hold potential in diagnosis of diseases such as obesity, diabetes, and leukemia.
Li, Shizhe; An, Li; Yu, Shao; Araneta, Maria Ferraris; Johnson, Christopher S.; Wang, Shumin; Shen, Jun
2015-01-01
Purpose 13C magnetic resonance spectroscopy (MRS) of human brain at 7 Tesla (T) may pose patient safety issues due to high RF power deposition for proton decoupling. The purpose of present work is to study the feasibility of in vivo 13C MRS of human brain at 7 T using broadband low RF power proton decoupling. Methods Carboxylic/amide 13C MRS of human brain by broadband stochastic proton decoupling was demonstrated on a 7 T scanner. RF safety was evaluated using the finite-difference time-domain method. 13C signal enhancement by nuclear Overhauser effect (NOE) and proton decoupling was evaluated in both phantoms and in vivo. Results At 7 T, the peak amplitude of carboxylic/amide 13C signals was increased by a factor of greater than 4 due to the combined effects of NOE and proton decoupling. The 7 T 13C MRS technique used decoupling power and average transmit power of less than 35 W and 3.6 W, respectively. Conclusion In vivo 13C MRS studies of human brain can be performed at 7 T well below the RF safety threshold by detecting carboxylic/amide carbons with broadband stochastic proton decoupling. PMID:25917936
Evaluation of manual resuscitators used in ICUs in Brazil*
Ortiz, Tatiana de Arruda; Forti, Germano; Volpe, Márcia Souza; Beraldo, Marcelo do Amaral; Amato, Marcelo Britto Passos; Carvalho, Carlos Roberto Ribeiro; Tucci, Mauro Roberto
2013-01-01
OBJECTIVE: To evaluate the performance of manual resuscitators (MRs) used in Brazil in accordance with international standards. METHODS: Using a respiratory system simulator, four volunteer physiotherapists employed eight MRs (five produced in Brazil and three produced abroad), which were tested for inspiratory and expiratory resistance of the patient valve; functioning of the pressure-limiting valve; and tidal volume (VT) generated when the one-handed and two-handed techniques were used. The tests were performed and analyzed in accordance with the American Society for Testing and Materials (ASTM) F920-93 criteria. RESULTS: Expiratory resistance was greater than 6 cmH2O . L−1 . s−1 in only one MR. The pressure-limiting valve, a feature of five of the MRs, opened at low pressures (< 17 cmH2O), and the maximal pressure was 32.0-55.9 cmH2O. Mean VT varied greatly among the MRs tested. The mean VT values generated with the one-handed technique were lower than the 600 mL recommended by the ASTM. In the situations studied, mean VT was generally lower from the Brazilian-made MRs that had a pressure-limiting valve. CONCLUSIONS: The resistances imposed by the patient valve met the ASTM criteria in all but one of the MRs tested. The pressure-limiting valves of the Brazilian-made MRs usually opened at low pressures, providing lower VT values in the situations studied, especially when the one-handed technique was used, suggesting that both hands should be used and that the pressure-limiting valve should be closed whenever possible. PMID:24310633
2004-01-01
Court Decision: 880 Southern Reporter, 2d Series 145; 2004 Aug 13 (date of decision). The Court of Appeal of Louisiana's Second Circuit held that a living will gave informed consent to the withdrawal of artificial nutrition and hydration even though the living will did not specifically identify such treatment as a life-sustaining procedure. Mrs. Doris suffered a stroke that left her in a semi-coma. According to two physicians, Mrs. Doris's condition was not likely to improve and her condition was characterized as a persistent vegetative state. Mrs. Doris received nourishment by way of a gastric feeding tube without which she would live for at most a week. Two of Mrs. Doris's children petitioned for the removal of her feeding tube. One of the children, Oris Pettis, opposed removing the feeding tube on the grounds that Mrs. Doris's living will was not properly witnessed and that Mrs. Doris did not give informed consent to remove a feeding tube. The Court of Appeal dispensed with Pettis's first argument by holding that the will was properly witnessed. Considering Pettis's second argument, the court held that a gastric feeding tube is not considered "comfort care" and is, instead, a "life-sustaining procedure." In 1991, the Louisiana legislature amended its laws to include "invasive administration of nutrition and hydration" within the definition of "life-sustaining procedure." Moreover, the court concluded that it was not necessary for a person writing a living will to specifically list the types of "life-sustaining procedures" he or she wished to withdraw. The Court affirmed a lower court decision denying Pettis' claims and upholding Mrs. Doris's living will.
Gella, Laxmi; Raman, Rajiv; Kulothungan, Vaitheeswaran; Saumya Pal, Swakshyar; Ganesan, Suganeswari; Sharma, Tarun
2016-06-01
To evaluate retinal sensitivity (RS) in subjects with diabetes in a population-based study and to elucidate associated risk factors for abnormal RS. A subset of 357 subjects from Sankara Nethralaya Diabetic Retinopathy Epidemiology and Molecular Genetics Study-II was included in this study. All subjects underwent detailed ophthalmic evaluation including microperimetry and spectral domain optical coherence tomography. The prevalence of abnormal mean retinal sensitivity (MRS) was 89.1%. MRS was significantly reduced in subjects with diabetes but no retinopathy when compared with non-diabetic subjects. MRS was reduced in moderate non-proliferative diabetic retinopathy (DR) and macular oedema (ME) at 8° (p=0.04, p=0.01, respectively) and in ME at 10° (p=0.009) and 12° (p=0.036) compared with no DR. Significant negative correlation was found between MRS and best corrected visual acuity, duration of diabetes, glycosylated haemoglobin and central foveal thickness. Increased retinal thickness remained a significant risk factor (OR, 1.02; p=0.044) for abnormal MRS. Altered inner retinal layers and foveal contour were associated with reduced MRS among subjects with DR and presence of epiretinal membrane, altered foveal contour and altered retinal pigment epithelium were associated with reduced MRS. Reduced RS in those subjects with diabetes but no retinopathy suggests the early neuronal damage in type 2 diabetes mellitus. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Medical Representatives' Intention to Use Information Technology in Pharmaceutical Marketing
Kwak, Eun-Seon
2016-01-01
Objectives Electronic detailing (e-detailing), the use of electronic devices to facilitate sales presentations to physicians, has been adopted and expanded in the pharmaceutical industry. To maximize the potential outcome of e-detailing, it is important to understand medical representatives (MRs)' behavior and attitude to e-detailing. This study investigates how information technology devices such as laptop computers and tablet PCs are utilized in pharmaceutical marketing, and it analyzes the factors influencing MRs' intention to use devices. Methods This study has adopted and modified the theory of Roger's diffusion of innovation model and the technology acceptance model. To test the model empirically, a questionnaire survey was conducted with 221 MRs who were working in three multinational or eleven domestic pharmaceutical companies in Korea. Results Overall, 28% and 35% of MRs experienced using laptop computers and tablet PCs in pharmaceutical marketing, respectively. However, the rates were different across different groups of MRs, categorized by age, education level, position, and career. The results showed that MRs' intention to use information technology devices was significantly influenced by perceived usefulness in general. Perceived ease of use, organizational and individual innovativeness, and several MR characteristics were also found to have significant impacts. Conclusions This study provides timely information about e-detailing devices to marketing managers and policy makers in the pharmaceutical industry for successful marketing strategy development by understanding the needs of MRs' intention to use information technology. Further in-depth study should be conducted to understand obstacles and limitations and to improve the strategies for better marketing tools. PMID:27895967
Residual stress measurement in a metal microdevice by micro Raman spectroscopy
NASA Astrophysics Data System (ADS)
Song, Chang; Du, Liqun; Qi, Leijie; Li, Yu; Li, Xiaojun; Li, Yuanqi
2017-10-01
Large residual stress induced during the electroforming process cannot be ignored to fabricate reliable metal microdevices. Accurate measurement is the basis for studying the residual stress. Influenced by the topological feature size of micron scale in the metal microdevice, residual stress in it can hardly be measured by common methods. In this manuscript, a methodology is proposed to measure the residual stress in the metal microdevice using micro Raman spectroscopy (MRS). To estimate the residual stress in metal materials, micron sized β-SiC particles were mixed in the electroforming solution for codeposition. First, the calculated expression relating the Raman shifts to the induced biaxial stress for β-SiC was derived based on the theory of phonon deformation potentials and Hooke’s law. Corresponding micro electroforming experiments were performed and the residual stress in Ni-SiC composite layer was both measured by x-ray diffraction (XRD) and MRS methods. Then, the validity of the MRS measurements was verified by comparing with the residual stress measured by XRD method. The reliability of the MRS method was further validated by the statistical student’s t-test. The MRS measurements were found to have no systematic error in comparison with the XRD measurements, which confirm that the residual stresses measured by the MRS method are reliable. Besides that, the MRS method, by which the residual stress in a micro inertial switch was measured, has been confirmed to be a convincing experiment tool for estimating the residual stress in metal microdevice with micron order topological feature size.
Sreeramareddy, Chandrashekhar T.; Harsha Kumar, H. N.; Sathian, Brijesh
2013-01-01
Background Inequalities in progress towards achievement of Millennium Development Goal four (MDG-4) reflect unequal access to child health services. Objective To examine the time trends, socio-economic and regional inequalities of under-five mortality rate (U5MR) in Nepal. Methods We analyzed the data from complete birth histories of four Nepal Demographic and Health Surveys (NDHS) done in the years 1996, 2001, 2006 and 2011. For each livebirth, we computed survival period from birth until either fifth birthday or the survey date. Using direct methods i.e. by constructing life tables, we calculated yearly U5MRs from 1991 to 2010. Projections were made for the years 2011 to 2015. For each NDHS, U5MRs were calculated according to child's sex, mother’s education, household wealth index, rural/urban residence, development regions and ecological zones. Inequalities were calculated as rate difference, rate ratio, population attributable risk and hazard ratio. Results Yearly U5MR (per 1000 live births) had decreased from 157.3 (95% CIs 178.0-138.9) in 1991 to 43.2 (95% CIs 59.1-31.5) in 2010 i.e. 114.1 reduction in absolute risk. Projected U5MR for the year 2015 was 54.33. U5MRs had decreased in absolute terms in all sub groups but relative inequalities had reduced for gender and rural/urban residence only. Wide inequalities existed by wealth and education and increased between 1996 and 2011. For lowest wealth quintile (as compared to highest quintile) hazard ratio (HR) increased from 1.37 (95% CIs 1.27, 1.49) to 2.54 ( 95% CIs 2.25, 2.86) and for mothers having no education (as compared to higher education) HR increased from 2.55 (95% CIs 1.95, 3.33) to 3.75 (95% CIs 3.17, 4.44). Changes in regional inequities were marginal and irregular. Conclusions Nepal is most likely to achieve MDG-4 but eductional and wealth inequalities may widen further. National health policies should address to reduce inequalities in U5MR through ‘inclusive policies'. PMID:24224010
Sexuality, Lung Cancer, and the Older Adult: An Unlikely Trio?
Williams, Anna Cathy; Reckamp, Karen; Freeman, Bonnie; Sidhu, Rupinder; Grant, Marcia
2013-01-01
Case Study Mrs. L. is a 60-year-old retired female teacher with stage IIIA squamous cell carcinoma of the lung, status postchemoradiation. She recently developed radiation pneumonitis, which was managed conservatively, and she did not require steroids. Mrs. L. has noted some progression of her underlying dyspnea. She is monitoring her oxygen saturation at home, and most of the time it is in the range of 94% to 96%. On one occasion only, her oxygen dropped to 88% and rapidly improved to the mid-90s. Her cough has improved for the past 4 to 6 weeks. She denies sputum production, congestion, or fever. Mrs. L. does not require a walker and uses a wheelchair only for long distances. She has occasional, slight dysphagia. A recent CT scan shows stable disease, and she is to return to the clinic in 2 months for restaging and possible further chemotherapy. Mrs. L. and her husband have been married for 33 years, and they have been very close. Until recently, they have continued to be sexually active and very intimate with each other. Since Mrs. L.’s diagnosis, and during treatment, the couple have become extremely stressed and psychologically spent. The act of sexual intercourse has ceased, yet they have attempted to remain close and maintain open communication. In addition to Mrs. L.’s increasing dyspnea, she has also suffered a great deal of fatigue and depression, along with alopecia and vaginal atrophy, due to the chemotherapy and radiation treatments. Both Mr. and Mrs. L. are very distressed over the change in their sexual lives. Mr. L. has mentioned that he now feels more like a "nursemaid" than a husband or lover. Mrs. L. has made concerted efforts to maintain intimacy with her husband, but her fatigue is profound. She has taken to sleeping in the living room, sitting up on the couch, as it relieves her dyspnea to some degree. PMID:25032012
Coulombe, Janie; Li, Linxin; Ganesh, Aravind; Silver, Louise; Rothwell, Peter M.
2017-01-01
Background and Purpose— Several studies have reported unexplained worse outcomes after stroke in women but none included the full spectrum of symptomatic ischemic cerebrovascular events while adjusting for prior handicap. Methods— Using a prospective population-based incident cohort of all transient ischemic attack/stroke (OXVASC [Oxford Vascular Study]) recruited between April 2002 and March 2014, we compared pre-morbid and post-event modified Rankin Scale score (mRS) in women and men and change in mRS score 1 month, 6 months, 1 year, and 5 years after stroke. Baseline stroke-related neurological impairment was measured with the National Institutes of Health Stroke Scale. Results— Among 2553 patients (50.6% women) with a first transient ischemic attack/ischemic stroke, women had a worse handicap 1 month after ischemic stroke (age-adjusted odds ratio for mRS score, 1.35; 95% confidence interval, 1.12–1.63). However, women also had a higher pre-morbid mRS score compared with men (age-adjusted odds ratio, 1.58; 95% confidence interval, 1.36–1.84). There was no difference in stroke severity when adjusting for age and pre-morbid mRS (odds ratio, 1.10; 95% confidence interval, 0.90–1.35) and no difference in the pre-/poststroke change in mRS at 1 month (age-adjusted odds ratio, 1.00; 95% confidence interval, 0.82–1.21), 6 months, 1 year, and 5 years. Women had a lower mortality rate, and there was no sex difference in risk of recurrent stroke. Conclusions— We found no evidence of a worse outcome of stroke in women when adjusting for age and pre-morbid mRS. Failure to account for sex differences in pre-morbid handicap could explain contradictory findings in previous studies. Properties of the mRS may also contribute to these inconsistencies. PMID:28798261
Renoux, Christel; Coulombe, Janie; Li, Linxin; Ganesh, Aravind; Silver, Louise; Rothwell, Peter M
2017-10-01
Several studies have reported unexplained worse outcomes after stroke in women but none included the full spectrum of symptomatic ischemic cerebrovascular events while adjusting for prior handicap. Using a prospective population-based incident cohort of all transient ischemic attack/stroke (OXVASC [Oxford Vascular Study]) recruited between April 2002 and March 2014, we compared pre-morbid and post-event modified Rankin Scale score (mRS) in women and men and change in mRS score 1 month, 6 months, 1 year, and 5 years after stroke. Baseline stroke-related neurological impairment was measured with the National Institutes of Health Stroke Scale. Among 2553 patients (50.6% women) with a first transient ischemic attack/ischemic stroke, women had a worse handicap 1 month after ischemic stroke (age-adjusted odds ratio for mRS score, 1.35; 95% confidence interval, 1.12-1.63). However, women also had a higher pre-morbid mRS score compared with men (age-adjusted odds ratio, 1.58; 95% confidence interval, 1.36-1.84). There was no difference in stroke severity when adjusting for age and pre-morbid mRS (odds ratio, 1.10; 95% confidence interval, 0.90-1.35) and no difference in the pre-/poststroke change in mRS at 1 month (age-adjusted odds ratio, 1.00; 95% confidence interval, 0.82-1.21), 6 months, 1 year, and 5 years. Women had a lower mortality rate, and there was no sex difference in risk of recurrent stroke. We found no evidence of a worse outcome of stroke in women when adjusting for age and pre-morbid mRS. Failure to account for sex differences in pre-morbid handicap could explain contradictory findings in previous studies. Properties of the mRS may also contribute to these inconsistencies. Copyright © 2017 The Author(s).
Magnetic resonance spectroscopy.
Hope, P L; Moorcraft, J
1991-09-01
MRS is a noninvasive technique that does not use ionizing radiation and can be used to measure relative metabolite concentrations in human tissues and organs in vivo. Phosphorus MRS can be used to study energy metabolites and intracellular pH. The first neonatal applications were described in 1983 in a study of cerebral metabolism. Since then, the value of cerebral MRS as research tool and an investigative technique has been confirmed, and its prognostic power in asphyxiated infants has been established. Techniques of spatial localization and quantitation have been developed, but studies of other organs and the use of other nuclei remain at a very preliminary stage. Considering the huge potential of MRS and the proliferation of high field magnets primarily designed for imaging, there has been a disappointing lack of progress in the development of clinical and research applications of spectroscopy. The logistic differences of studying sick infants in strong magnetic fields make MRS a time-consuming and labor-intensive investigation, which will inevitably limit its widespread routine use. Research studies are hampered by the diversity of spectroscopic and signal processing techniques, which make comparisons of data from different groups impossible. Some techniques for the assessment of cerebral hemodynamics such as doppler ultrasound and near infrared spectroscopy have the advantage of being available at the cotside, but MRS is unique in providing quantitative information about a wide range of intracellular metabolites. The altricial development of MRS as a clinical investigative tool in neonatology can be ascribed partly to practical difficulties, but these should not detract from the exciting possibilities opened up by a technique that gives a noninvasive insight into intracellular chemistry. The metabolic information from MRS is an invaluable addition to the information provided by other techniques and will certainly play an important role in unraveling the sequence of events between an hypoxic-ischemic insult and cell death. A better understanding of these mechanisms is a prerequisite to the development of rational therapeutic maneuvers following asphyxial insults.
Barbara, Andrea; Poscia, Andrea; De Meo, Concetta; De Waure, Chiara; Anzelmo, Vincenza; Santoro, Paolo Emilio; Maruccia, Antonio; Giubbini, Gabriele; Corsaro, Alice; Berloco, Filippo; Damiani, Gianfranco; Ricciardi, Walter; Laurenti, Patrizia
2017-01-01
In Italy annual flu vaccination for health care workers is recommended but coverage is usually unsatisfying. The compliance is even worse among medical residents (MRs) both in literature, both in our experience: in the flu season 2014/ 15 only 0.6% of MRs enrolled at the Università Cattolica del Sacro Cuore (UCSC) were vaccinated. For this reason, during the influenza season 2015/16, the Institute of Public Health of the UCSC, in collaboration with the Health Management of the "Agostino Gemelli" Teaching Hospital (FPG) and with the directive board of the Medical Specialization Schools (SSM) present at the University has tested several strategies to improve awareness and adherence to flu vaccination campaign by its staff. This study aims to analyze the impact of the strategies used during the 2015/16 campaign on flu vaccination coverage among MRs of an important Italian Teaching Hospital. The study was conducted among MRs enrolled at the UCSC - FPG in 2015/16. The data was collected by the Occupational Medicine which, during the influenza seasons, immunize MRs against influenza free of charge. For each variable - vaccination, area of specialization (surgical, medical, clinical services), typology of SSM - was measured the absolute and percentage frequency. In order to compare the flu vaccination coverage between seasons 2014/15 and 2015/16 and between areas of specialization in 2015/16 chi-square test was used (statistical significance level of 0.05). The data were analyzed using STATA Software. Were included in the analysis 42 SSM with a total of 1041 MRs. During the vaccination campaign 2015/16, flu vaccine was administered to 99 MRs (9.5%), 8.9% more than in the previous season (p<0.001). There is also a significant difference in vaccine coverage between surgical, medical and clinical services areas in 2015/16 (p <0.001). The highest vaccination coverage was recorded among MRs of Hematology and Urology (54.5%). However, no one MRs had undergone flu vaccination in about 40% of SSM. Seasonal flu vaccination among HCWs is important to protect patients as well as them self and their family members. Considering that MRs represent the next generation of HCWs, they should be sensitized about the importance of preventing the spread of influenza in hospital population, becoming an active part of the necessary cultural change. This study highlights a first and promising, although insufficient, increase in flu vaccination coverage among MRs enrolled at the UCSC - FPG after introducing simple strategies to promote vaccination itself and, more generally, positive and proactive behaviors. The study summarizes the results in the short term, but it is well known that cultural changes require time and constancy. Therefore, it will be useful to monitor the improvement over time and extend the assessment to all health care professionals.
Resource Aware Intelligent Network Services (RAINS) Final Technical Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lehman, Tom; Yang, Xi
The Resource Aware Intelligent Network Services (RAINS) project conducted research and developed technologies in the area of cyber infrastructure resource modeling and computation. The goal of this work was to provide a foundation to enable intelligent, software defined services which spanned the network AND the resources which connect to the network. A Multi-Resource Service Plane (MRSP) was defined, which allows resource owners/managers to locate and place themselves from a topology and service availability perspective within the dynamic networked cyberinfrastructure ecosystem. The MRSP enables the presentation of integrated topology views and computation results which can include resources across the spectrum ofmore » compute, storage, and networks. The RAINS project developed MSRP includes the following key components: i) Multi-Resource Service (MRS) Ontology/Multi-Resource Markup Language (MRML), ii) Resource Computation Engine (RCE), iii) Modular Driver Framework (to allow integration of a variety of external resources). The MRS/MRML is a general and extensible modeling framework that allows for resource owners to model, or describe, a wide variety of resource types. All resources are described using three categories of elements: Resources, Services, and Relationships between the elements. This modeling framework defines a common method for the transformation of cyber infrastructure resources into data in the form of MRML models. In order to realize this infrastructure datification, the RAINS project developed a model based computation system, i.e. “RAINS Computation Engine (RCE)”. The RCE has the ability to ingest, process, integrate, and compute based on automatically generated MRML models. The RCE interacts with the resources thru system drivers which are specific to the type of external network or resource controller. The RAINS project developed a modular and pluggable driver system which facilities a variety of resource controllers to automatically generate, maintain, and distribute MRML based resource descriptions. Once all of the resource topologies are absorbed by the RCE, a connected graph of the full distributed system topology is constructed, which forms the basis for computation and workflow processing. The RCE includes a Modular Computation Element (MCE) framework which allows for tailoring of the computation process to the specific set of resources under control, and the services desired. The input and output of an MCE are both model data based on MRS/MRML ontology and schema. Some of the RAINS project accomplishments include: Development of general and extensible multi-resource modeling framework; Design of a Resource Computation Engine (RCE) system which includes the following key capabilities; Absorb a variety of multi-resource model types and build integrated models; Novel architecture which uses model based communications across the full stack for all Flexible provision of abstract or intent based user facing interfaces; Workflow processing based on model descriptions; Release of the RCE as an open source software; Deployment of RCE in the University of Maryland/Mid-Atlantic Crossroad ScienceDMZ in prototype mode with a plan under way to transition to production; Deployment at the Argonne National Laboratory DTN Facility in prototype mode; Selection of RCE by the DOE SENSE (SDN for End-to-end Networked Science at the Exascale) project as the basis for their orchestration service.« less
Honeybul, Stephen; Ho, Kwok M; Blacker, David W
2016-08-01
There continues to be considerable interest in the use of decompressive hemicraniectomy in the management of malignant cerebral artery infarction; however, concerns remain about long-term outcome. To assess opinion on consent and acceptable outcome among a wide range of healthcare workers. Seven hundred seventy-three healthcare workers at the 2 major public neurosurgical centers in Western Australia participated. Participants were asked to record their opinion on consent and acceptable outcome based on the modified Rankin Score (mRS). The evidence for clinical efficacy of the procedure was presented, and participants were then asked to reconsider their initial responses. Of the 773 participants included in the study, 407 (52.7%) initially felt that they would provide consent for a decompressive craniectomy as a lifesaving procedure, but only a minority of them considered an mRS score of 4 or 5 an acceptable outcome (for mRS score ≤4, n = 67, 8.7%; for mRS score = 4, n = 57, 7.4%). After the introduction of the concept of the disability paradox and the evidence for the clinical efficacy of decompressive craniectomy, more participants were unwilling to accept decompressive craniectomy (18.1% vs 37.8%), but at the same time, more were willing to accept an mRS score ≤4 as an acceptable outcome (for mRS score ≤4, n = 92, 11.9%; for mRS score = 4, n = 79, 10.2%). Most participants felt survival with dependency to be unacceptable. However, many would be willing to provide consent for surgery in the hopes that they may survive with some degree of independence. DESTINY, Decompressive Surgery for the Treatment of Malignant Infarction of the Middle Cerebral ArterymRS, modified Rankin Scale.
Almuqbel, Mustafa; Melzer, Tracy R; Myall, Daniel J; MacAskill, Michael R; Pitcher, Toni L; Livingston, Leslie; Wood, Kyla-Louise; Keenan, Ross J; Dalrymple-Alford, John C; Anderson, Tim J
2016-01-01
Parkinson's Disease (PD) is classified as a motor disorder, but most patients develop cognitive impairment, and eventual dementia (PDD). Predictive neurobiomarkers may be useful in the identification of those patients at imminent risk of PDD. Given the compromised cerebral integrity in PDD, we investigated whether brain metabolites track disease progression over time. Proton Magnetic Resonance Spectroscopy (MRS) was used to identify brain metabolic changes associated with cognitive impairment and dementia in PD. Forty-nine healthy participants and 130 PD patients underwent serial single voxel proton MRS and neuropsychological testing. At baseline patients were classified as either having normal cognitive status (PDN, n = 77), mild cognitive impairment (PDMCI, n = 33), or dementia (PDD, n = 20). Posterior cingulate cortex (PCC) was examined to quantify N-acetylaspartate (NAA), choline (Cho), creatine (Cr), and myo-inositol (mI). A hierarchical Bayesian model was used to assess whether cognitive ability and other covariates were related to baseline MRS values and changes in MRS over time. At baseline, relative to controls, PDD had significantly decreased NAA/Cr and increased Cho/Cr. However, these differences did not remain significant after accounting for age, sex, and MDS-UPDRS III. At follow-up, no significant changes in MRS metabolite ratios were detected, with no relationship found between MRS measures and change in cognitive status. Unlike Alzheimer's disease, single voxel MR spectroscopy of the PCC failed to show any significant association with cognitive status at baseline or over time. This suggests that MRS of PCC is not a clinically useful biomarker for tracking or predicting cognitive impairment in Parkinson's disease. Copyright © 2015 Elsevier Ltd. All rights reserved.
Katki, Hormuzd A; Schiffman, Mark
2018-05-01
Our work involves assessing whether new biomarkers might be useful for cervical-cancer screening across populations with different disease prevalences and biomarker distributions. When comparing across populations, we show that standard diagnostic accuracy statistics (predictive values, risk-differences, Youden's index and Area Under the Curve (AUC)) can easily be misinterpreted. We introduce an intuitively simple statistic for a 2 × 2 table, Mean Risk Stratification (MRS): the average change in risk (pre-test vs. post-test) revealed for tested individuals. High MRS implies better risk separation achieved by testing. MRS has 3 key advantages for comparing test performance across populations with different disease prevalences and biomarker distributions. First, MRS demonstrates that conventional predictive values and the risk-difference do not measure risk-stratification because they do not account for test-positivity rates. Second, Youden's index and AUC measure only multiplicative relative gains in risk-stratification: AUC = 0.6 achieves only 20% of maximum risk-stratification (AUC = 0.9 achieves 80%). Third, large relative gains in risk-stratification might not imply large absolute gains if disease is rare, demonstrating a "high-bar" to justify population-based screening for rare diseases such as cancer. We illustrate MRS by our experience comparing the performance of cervical-cancer screening tests in China vs. the USA. The test with the worst AUC = 0.72 in China (visual inspection with acetic acid) provides twice the risk-stratification (i.e. MRS) of the test with best AUC = 0.83 in the USA (human papillomavirus and Pap cotesting) because China has three times more cervical precancer/cancer. MRS could be routinely calculated to better understand the clinical/public-health implications of standard diagnostic accuracy statistics. Published by Elsevier Inc.
Depression Status Is Associated with Functional Decline Over 1-Year Following Acute Stroke.
El Husseini, Nada; Goldstein, Larry B; Peterson, Eric D; Zhao, Xin; Olson, DaiWai M; Williams, John W; Bushnell, Cheryl; Laskowitz, Daniel T
2017-07-01
We investigated the independent association of depression status at 3 and 12 months after stroke and functional decline. Data were obtained as part of the multicenter Adherence eValuation After Ischemic stroke Longitudinal (AVAIL) registry. Depression was assessed with the Patient Health Questionnaire-8 (depression, PHQ-8 ≥ 10), and functional status was assessed with the modified Rankin score (mRS) at 3 and 12 months following hospitalization for ischemic stroke. We used logistic regression analyses to evaluate the independent association between the change in depression rating and the change in mRS. Among 1444 patients, 75% did not have depression at either time point, 9.2% had persistent depression, 8.7% had resolving depression, and 7% had incident depression at 12 months. After covariate adjustment, depression status at 3 and 12 months remained associated with worsening mRS (P = .01). Compared with patients without depression, those with resolving depression were less likely to have a worsening mRS (odds ratio [OR] = .49, 95% confidence interval [CI]: .29-0.83). There was no difference in functional decline between those with no depression and those with persistent depression; however, those with persistent depression had worse mRS at both time points (median mRS: 2.5 [Q1-Q3: 2-3] at 3 months; 2 [2-3] at 12 months) than those with no depression (mRS: 1 [0-2] at both 3 and 12 months), P < .0001. Patients with resolving depression in the first year after stroke were less likely to have functional deterioration than those without depression. Greater functional impairment was present in the setting of depression. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.
Simpson, Robin; Devenyi, Gabriel A; Jezzard, Peter; Hennessy, T Jay; Near, Jamie
2017-01-01
To introduce a new toolkit for simulation and processing of magnetic resonance spectroscopy (MRS) data, and to demonstrate some of its novel features. The FID appliance (FID-A) is an open-source, MATLAB-based software toolkit for simulation and processing of MRS data. The software is designed specifically for processing data with multiple dimensions (eg, multiple radiofrequency channels, averages, spectral editing dimensions). It is equipped with functions for importing data in the formats of most major MRI vendors (eg, Siemens, Philips, GE, Agilent) and for exporting data into the formats of several common processing software packages (eg, LCModel, jMRUI, Tarquin). This paper introduces the FID-A software toolkit and uses examples to demonstrate its novel features, namely 1) the use of a spectral registration algorithm to carry out useful processing routines automatically, 2) automatic detection and removal of motion-corrupted scans, and 3) the ability to perform several major aspects of the MRS computational workflow from a single piece of software. This latter feature is illustrated through both high-level processing of in vivo GABA-edited MEGA-PRESS MRS data, as well as detailed quantum mechanical simulations to generate an accurate LCModel basis set for analysis of the same data. All of the described processing steps resulted in a marked improvement in spectral quality compared with unprocessed data. Fitting of MEGA-PRESS data using a customized basis set resulted in improved fitting accuracy compared with a generic MEGA-PRESS basis set. The FID-A software toolkit enables high-level processing of MRS data and accurate simulation of in vivo MRS experiments. Magn Reson Med 77:23-33, 2017. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
Kuroda, Hiroshi; Fujihara, Kazuo; Mugikura, Shunji; Takahashi, Shoki; Kushimoto, Shigeki; Aoki, Masashi
2016-01-15
Proton magnetic resonance spectroscopy ((1)H-MRS) was recently used to examine altered metabolism in the white matter (WM) of patients experiencing carbon monoxide (CO) poisoning; however, only a small number of patients with delayed neurologic sequelae (DNS) were analyzed. We aimed to detect altered metabolism in the WM of patients with DNS using (1)H-MRS; to explore its clinical relevance in the management of patients experiencing CO poisoning. Patients experiencing acute CO poisoning underwent (1)H-MRS and cerebrospinal fluid (CSF) examination within 1week and at 1month after acute poisoning. Metabolites including choline-containing compounds (Cho), creatine (Cr), N-acetylaspartate (NAA), and lactate were measured from the periventricular WM. Myelin basic protein (MBP) concentrations were measured in CSF. Fifty-two patients experiencing acute CO poisoning (15 with DNS, 37 without DNS; median age, 49years; 65% males) underwent (1)H-MRS. Within 1week, NAA/Cr ratios, reflecting neuroaxonal viability, were lower in patients with DNS than in those without DNS (P<0.05). At 1month, when 9 of 15 patients (60%) developed DNS, Cho/Cr ratios were higher, and NAA/Cr and NAA/Cho ratios lower in patients with DNS (P=0.0001, <0.0001, and <0.0001, respectively), indicating increased membrane metabolism and decreased neuroaxonal viability. (1)H-MRS parameter abnormalities correlated with the elevation of MBP in CSF. The presence of a lactate peak was a predictor for a poor long-term outcome. (1)H-MRS within 1week may be useful for predicting DNS development; (1)H-MRS at 1month may be useful for discriminating patients with DNS and predicting long-term outcomes. Copyright © 2015 Elsevier B.V. All rights reserved.
Code of Federal Regulations, 2010 CFR
2010-07-01
... assigned to two or more persons in the alternative, for example, “John B. Smith or Mrs. Mary J. Smith” or “John B. Smith or Mrs. Mary J. Smith or the survivor,” may be assigned by one of them at maturity or... the names of or assigned to two or more persons jointly, for example, “John B. Smith and Mrs. Mary J...
Clastic rocks associated with the Midcontinent rift system in Iowa
Anderson, Raymond R.; McKay, Robert M.
1997-01-01
The Middle Proterozoic Midcontinent Rift System (MRS) of North America is a failed rift that formed in response to region-wide stresses about 1,100 Ma. In Iowa, the MRS is buried beneath 2,200?3,500 ft of Paleozoic and Mesozoic sedimentary rocks and Quaternary glaciogenic deposits. An extremely large volume of sediments was deposited within basins associated with the rift at several stages during its development. Although the uplift of a rift-axial horst resulted in the erosional removal of most of these clastic rocks from the central region of the MRS in Iowa, thick sequences are preserved in a series of horst-bounding basins. Recent studies incorporating petrographic analysis, geophysical modeling, and other analytical procedures have led to the establishment of a preliminary stratigraphy for these clastic rocks and interpretations of basin geometries. This information has allowed the refinement of existing theories and history of MRS formation in Iowa. Additionally, drill samples previously interpreted as indicating the existence of early Paleozoic basins overlying the Proterozoic MRS basins were re-examined. Samples previously interpreted as deep-lying Paleozoic rocks are now known to have caved from upper levels of the drillhole and were out of stratigraphic position. No deep Paleozoic basins exist in this area. These investigations led to the development of petrographic parameters useful in differentiating the Proterozoic MRS Red clastics from Paleozoic clastic rocks having similar lithologies.
Liu, Chia-Ying; Redheuil, Alban; Ouwerkerk, Ronald; Lima, Joao A. C.; Bluemke, David A.
2011-01-01
Proton MR spectroscopy (1H-MRS) has been used for in vivo quantification of intracellular triglycerides within the sarcolemma. The purpose of this study was to assess whether breath-hold dual-echo in- and out-of-phase MRI at 3.0 T can quantify the fat content of the myocardium. Biases, including T1, T2∗, and noise, that confound the calculation of the fat fraction were carefully corrected. Thirty-four of 46 participants had both MRI and MRS data. The fat fractions from MRI showed a strong correlation with fat fractions from MRS (r = 0.78; P < 0.05). The mean myocardial fat fraction for all 34 subjects was 0.7 ± 0.5% (range: 0.11–3%) assessed with MRS and 1.04 ± 0.4% (range: 0.32–2.44%) assessed with in- and out-of-phase MRI (P < 0.05). Scanning times were less than 15 sec for Dixon imaging, plus an additional minute for the acquisition used for calculation, and 15-20 min for MRS. The average postprocessing time for MRS was 3 min and 5 min for MRI including T2∗ measurement. We conclude that the dual echo method provides a rapid means to detect and quantifying myocardial fat content in vivo. Correction/adjustment for field inhomogeneity using three or more echoes seems crucial for the dual echo approach. PMID:20373390
Long-echo time MR spectroscopy for skeletal muscle acetylcarnitine detection.
Lindeboom, Lucas; Nabuurs, Christine I; Hoeks, Joris; Brouwers, Bram; Phielix, Esther; Kooi, M Eline; Hesselink, Matthijs K C; Wildberger, Joachim E; Stevens, Robert D; Koves, Timothy; Muoio, Deborah M; Schrauwen, Patrick; Schrauwen-Hinderling, Vera B
2014-11-01
Animal models suggest that acetylcarnitine production is essential for maintaining metabolic flexibility and insulin sensitivity. Because current methods to detect acetylcarnitine involve biopsy of the tissue of interest, noninvasive alternatives to measure acetylcarnitine concentrations could facilitate our understanding of its physiological relevance in humans. Here, we investigated the use of long-echo time (TE) proton magnetic resonance spectroscopy (1H-MRS) to measure skeletal muscle acetylcarnitine concentrations on a clinical 3T scanner. We applied long-TE 1H-MRS to measure acetylcarnitine in endurance-trained athletes, lean and obese sedentary subjects, and type 2 diabetes mellitus (T2DM) patients to cover a wide spectrum in insulin sensitivity. A long-TE 1H-MRS protocol was implemented for successful detection of skeletal muscle acetylcarnitine in these individuals. There were pronounced differences in insulin sensitivity, as measured by hyperinsulinemic-euglycemic clamp, and skeletal muscle mitochondrial function, as measured by phosphorus-MRS (31P-MRS), across groups. Insulin sensitivity and mitochondrial function were highest in trained athletes and lowest in T2DM patients. Skeletal muscle acetylcarnitine concentration showed a reciprocal distribution, with mean acetylcarnitine concentration correlating with mean insulin sensitivity in each group. These results demonstrate that measuring acetylcarnitine concentrations with 1H-MRS is feasible on clinical MR scanners and support the hypothesis that T2DM patients are characterized by a decreased formation of acetylcarnitine, possibly underlying decreased insulin sensitivity.
Long–echo time MR spectroscopy for skeletal muscle acetylcarnitine detection
Lindeboom, Lucas; Nabuurs, Christine I.; Hoeks, Joris; Brouwers, Bram; Phielix, Esther; Kooi, M. Eline; Hesselink, Matthijs K.C.; Wildberger, Joachim E.; Stevens, Robert D.; Koves, Timothy; Muoio, Deborah M.; Schrauwen, Patrick; Schrauwen-Hinderling, Vera B.
2014-01-01
Animal models suggest that acetylcarnitine production is essential for maintaining metabolic flexibility and insulin sensitivity. Because current methods to detect acetylcarnitine involve biopsy of the tissue of interest, noninvasive alternatives to measure acetylcarnitine concentrations could facilitate our understanding of its physiological relevance in humans. Here, we investigated the use of long–echo time (TE) proton magnetic resonance spectroscopy (1H-MRS) to measure skeletal muscle acetylcarnitine concentrations on a clinical 3T scanner. We applied long-TE 1H-MRS to measure acetylcarnitine in endurance-trained athletes, lean and obese sedentary subjects, and type 2 diabetes mellitus (T2DM) patients to cover a wide spectrum in insulin sensitivity. A long-TE 1H-MRS protocol was implemented for successful detection of skeletal muscle acetylcarnitine in these individuals. There were pronounced differences in insulin sensitivity, as measured by hyperinsulinemic-euglycemic clamp, and skeletal muscle mitochondrial function, as measured by phosphorus-MRS (31P-MRS), across groups. Insulin sensitivity and mitochondrial function were highest in trained athletes and lowest in T2DM patients. Skeletal muscle acetylcarnitine concentration showed a reciprocal distribution, with mean acetylcarnitine concentration correlating with mean insulin sensitivity in each group. These results demonstrate that measuring acetylcarnitine concentrations with 1H-MRS is feasible on clinical MR scanners and support the hypothesis that T2DM patients are characterized by a decreased formation of acetylcarnitine, possibly underlying decreased insulin sensitivity. PMID:25271624
Just, Nathalie; Xin, Lijing; Frenkel, Hanne; Gruetter, Rolf
2013-07-01
To date, only a couple of functional MR spectroscopy (fMRS) studies were conducted in rats. Due to the low temporal resolution of (1)H MRS techniques, prolonged stimulation paradigms are necessary for investigating the metabolic outcome in the rat brain during functional challenge. However, sustained activation of cortical areas is usually difficult to obtain due to neural adaptation. Anesthesia, habituation, high variability of the basal state metabolite concentrations as well as low concentrations of the metabolites of interest such as lactate (Lac), glucose (Glc) or γ-aminobutyric acid (GABA) and small expected changes of metabolite concentrations need to be addressed. In the present study, the rat barrel cortex was reliably and reproducibly activated through sustained trigeminal nerve (TGN) stimulation. In addition, TGN stimulation induced significant positive changes in lactate (+1.01 μmol/g, p<0.008) and glutamate (+0.92 μmol/g, p<0.02) and significant negative aspartate changes (-0.63 μmol/g, p<0.004) using functional (1)H MRS at 9.4 T in agreement with previous changes observed in human fMRS studies. Finally, for the first time, the dynamics of lactate, glucose, aspartate and glutamate concentrations during sustained somatosensory activation in rats using fMRS were assessed. These results allow demonstrating the feasibility of fMRS measurements during prolonged barrel cortex activation in rats. Copyright © 2013 Elsevier Inc. All rights reserved.
Westman, Eric; Wahlund, Lars-Olof; Foy, Catherine; Poppe, Michaela; Cooper, Allison; Murphy, Declan; Spenger, Christian; Lovestone, Simon; Simmons, Andrew
2011-01-01
Alzheimer's disease is the most common form of neurodegenerative disorder and early detection is of great importance if new therapies are to be effectively administered. We have investigated whether the discrimination between early Alzheimer's disease (AD) and elderly healthy control subjects can be improved by adding magnetic resonance spectroscopy (MRS) measures to magnetic resonance imaging (MRI) measures. In this study 30 AD patients and 36 control subjects were included. High resolution T1-weighted axial magnetic resonance images were obtained from each subject. Automated regional volume segmentation and cortical thickness measures were determined for the images. 1H MRS was acquired from the hippocampus and LCModel was used for metabolic quantification. Altogether, this yielded 58 different volumetric, cortical thickness and metabolite ratio variables which were used for multivariate analysis to distinguish between subjects with AD and Healthy controls. Combining MRI and MRS measures resulted in a sensitivity of 97% and a specificity of 94% compared to using MRI or MRS measures alone (sensitivity: 87%, 76%, specificity: 86%, 83% respectively). Adding the MRS measures to the MRI measures more than doubled the positive likelihood ratio from 6 to 17. Adding MRS measures to a multivariate analysis of MRI measures resulted in significantly better classification than using MRI measures alone. The method shows strong potential for discriminating between Alzheimer's disease and controls.
Magnetic resonance spectroscopy of the human brain
NASA Astrophysics Data System (ADS)
Strózik-Kotlorz, D.
2014-01-01
I give a brief description of the magnetic resonance spectroscopy (MRS) in the human brain examinations. MRS allows a noninvasive chemical analysis of the brain using a standard high field MR system. Nowadays, the dominant form of MR brain spectroscopy is proton spectroscopy. Two main techniques of MRS, which utilize the chemical shift of metabolites in the external magnetic field, are SVS (single voxel) and CSI (single slice). The major peaks in the spectrum of a normal brain include NAA, Cr, Cho and m-Ins, which are neuronal, energetic, membrane turnover and glial markers, respectively. In disease, two pathological metabolites can be found in the brain spectra: Lac, which is end product of anaerobic glycolysis and Lip, which is a marker of membrane breakdown, occurring in necrosis. The common way to analyze clinical spectra is to determine metabolite ratios, e.g. NAA/Cr, Cho/Cr, Cho/NAA. This analysis permits a safe and noninvasive examination of the brain tissue as each disease state has its own characteristic spectroscopic image. MRS is a valuable diagnostic tool in such clinical applications as detecting brain tumors and differentiating tumors from inflammatory and infectious processes. Proton MRS is also very helpful in diagnostic of ischemic lesions, Alzheimer's disease and hepatic encephalopathy. The MRS brain spectra should always be correlated with the Magnetic Resonance Imaging (MRI) results and alone cannot make neurological diagnosis.
Robust and Elastic Lunar and Martian Structures from 3D-Printed Regolith Inks
NASA Astrophysics Data System (ADS)
Jakus, Adam E.; Koube, Katie D.; Geisendorfer, Nicholas R.; Shah, Ramille N.
2017-03-01
Here, we present a comprehensive approach for creating robust, elastic, designer Lunar and Martian regolith simulant (LRS and MRS, respectively) architectures using ambient condition, extrusion-based 3D-printing of regolith simulant inks. The LRS and MRS powders are characterized by distinct, highly inhomogeneous morphologies and sizes, where LRS powder particles are highly irregular and jagged and MRS powder particles are rough, but primarily rounded. The inks are synthesized via simple mixing of evaporant, surfactant, and plasticizer solvents, polylactic-co-glycolic acid (30% by solids volume), and regolith simulant powders (70% by solids volume). Both LRS and MRS inks exhibit similar rheological and 3D-printing characteristics, and can be 3D-printed at linear deposition rates of 1-150 mm/s using 300 μm to 1.4 cm-diameter nozzles. The resulting LRS and MRS 3D-printed materials exhibit similar, but distinct internal and external microstructures and material porosity (~20-40%). These microstructures contribute to the rubber-like quasi-static and cyclic mechanical properties of both materials, with young’s moduli ranging from 1.8 to 13.2 MPa and extension to failure exceeding 250% over a range of strain rates (10-1-102 min-1). Finally, we discuss the potential for LRS and MRS ink components to be reclaimed and recycled, as well as be synthesized in resource-limited, extraterrestrial environments.
Genetic and Biochemical Analysis of High Iron Toxicity in Yeast
Lin, Huilan; Li, Liangtao; Jia, Xuan; Ward, Diane McVey; Kaplan, Jerry
2011-01-01
Iron storage in yeast requires the activity of the vacuolar iron transporter Ccc1. Yeast with an intact CCC1 are resistant to iron toxicity, but deletion of CCC1 renders yeast susceptible to iron toxicity. We used genetic and biochemical analysis to identify suppressors of high iron toxicity in Δccc1 cells to probe the mechanism of high iron toxicity. All genes identified as suppressors of high iron toxicity in aerobically grown Δccc1 cells encode organelle iron transporters including mitochondrial iron transporters MRS3, MRS4, and RIM2. Overexpression of MRS3 suppressed high iron toxicity by decreasing cytosolic iron through mitochondrial iron accumulation. Under anaerobic conditions, Δccc1 cells were still sensitive to high iron toxicity, but overexpression of MRS3 did not suppress iron toxicity and did not result in mitochondrial iron accumulation. We conclude that Mrs3/Mrs4 can sequester iron within mitochondria under aerobic conditions but not anaerobic conditions. We show that iron toxicity in Δccc1 cells occurred under both aerobic and anaerobic conditions. Microarray analysis showed no evidence of oxidative damage under anaerobic conditions, suggesting that iron toxicity may not be solely due to oxidative damage. Deletion of TSA1, which encodes a peroxiredoxin, exacerbated iron toxicity in Δccc1 cells under both aerobic and anaerobic conditions, suggesting a unique role for Tsa1 in iron toxicity. PMID:21115478
Sun, Chuan-bin; You, Yong-sheng; Liu, Zhe; Zheng, Lin-yan; Chen, Pei-qing; Yao, Ke; Xue, An-quan
2016-01-01
To investigate the morphological characteristics of myopic macular retinoschisis (MRS) in teenagers with high myopia, six male (9 eyes) and 3 female (4 eyes) teenagers with typical MRS identified from chart review were evaluated. All cases underwent complete ophthalmic examinations including best corrected visual acuity (BCVA), indirect ophthalmoscopy, colour fundus photography, B-type ultrasonography, axial length measurement, and spectral-domain optical coherence tomography (SD-OCT). The average age was 17.8 ± 1.5 years, average refractive error was −17.04 ± 3.04D, average BCVA was 0.43 ± 0.61, and average axial length was 30.42 ± 1.71 mm. Myopic macular degenerative changes (MDC) by colour fundus photographs revealed Ohno-Matsui Category 1 in 4 eyes, and Category 2 in 9 eyes. Posterior staphyloma was found in 9 eyes. SD-OCT showed outer MRS in all 13 eyes, internal limiting membrane detachment in 7 eyes, vascular microfolds in 2 eyes, and inner MRS in 1 eye. No premacular structures such as macular epiretinal membrane or partially detached posterior hyaloids were found. Our results showed that MRS rarely occurred in highly myopic teenagers, and was not accompanied by premacular structures, severe MDC, or even obvious posterior staphyloma. This finding indicates that posterior scleral expansion is probably the main cause of MRS. PMID:27294332
Fuss, Taylor L.; Cheng, Leo L.
2016-01-01
According to World Health Organization (WHO) estimates, cancer is responsible for more deaths than all coronary heart disease or stroke worldwide, serving as a major public health threat around the world. High resolution magic angle spinning (HRMAS) magnetic resonance spectroscopy (MRS) has demonstrated its usefulness in the identification of cancer metabolic markers with the potential to improve diagnosis and prognosis for the oncology clinic, due partially to its ability to preserve tissue architecture for subsequent histological and molecular pathology analysis. Capable of the quantification of individual metabolites, ratios of metabolites, and entire metabolomic profiles, HRMAS MRS is one of the major techniques now used in cancer metabolomic research. This article reviews and discusses literature reports of HRMAS MRS studies of cancer metabolomics published between 2010 and 2015 according to anatomical origins, including brain, breast, prostate, lung, gastrointestinal, and neuroendocrine cancers. These studies focused on improving diagnosis and understanding patient prognostication, monitoring treatment effects, as well as correlating with the use of in vivo MRS in cancer clinics. PMID:27011205
An Integrated MRI and MRS Approach to Evaluation of Multiple Sclerosis with Cognitive Impairment
NASA Astrophysics Data System (ADS)
Liang, Zhengrong; Li, Lihong; Lu, Hongbing; Huang, Wei; Tudorica, Alina; Krupp, Lauren
Magnetic resonance imaging and spectroscopy (MRI/MRS) plays a unique role in multiple sclerosis (MS) evaluation, because of its ability to provide both high image contrast and significant chemical change among brain tissues. The image contrast renders the possibility of quantifying the tissue volumetric and texture variations, e.g., cerebral atrophy and progressing speed, reflecting the ongoing destructive pathologic processes. Any chemical change reflects an early sign of pathological alteration, e.g., decreased N-acetyl aspartate (NAA) in lesions and normal appearing white matter, related to axonal damage or dysfunction. Both MRI and MRS encounter partial volume (PV) effect, which compromises the quantitative capability, especially for MRS. This work aims to develop a statistical framework to segment the tissue mixtures inside each image element, eliminating theoretically the PV effect, and apply the framework to the evaluation of MS with cognitive impairment. The quantitative measures from MRI/MRS neuroimaging are strongly correlated with the qualitative neuropsychological scores of Brief Repeatable Battery (BRB) test on cognitive impairment, demonstrating the usefulness of the PV image segmentation framework in this clinically significant problem.
Casey, D T; Frenje, J A; Gatu Johnson, M; Séguin, F H; Li, C K; Petrasso, R D; Glebov, V Yu; Katz, J; Knauer, J P; Meyerhofer, D D; Sangster, T C; Bionta, R M; Bleuel, D L; Döppner, T; Glenzer, S; Hartouni, E; Hatchett, S P; Le Pape, S; Ma, T; MacKinnon, A; McKernan, M A; Moran, M; Moses, E; Park, H-S; Ralph, J; Remington, B A; Smalyuk, V; Yeamans, C B; Kline, J; Kyrala, G; Chandler, G A; Leeper, R J; Ruiz, C L; Cooper, G W; Nelson, A J; Fletcher, K; Kilkenny, J; Farrell, M; Jasion, D; Paguio, R
2012-10-01
A magnetic recoil spectrometer (MRS) has been installed and extensively used on OMEGA and the National Ignition Facility (NIF) for measurements of the absolute neutron spectrum from inertial confinement fusion implosions. From the neutron spectrum measured with the MRS, many critical implosion parameters are determined including the primary DT neutron yield, the ion temperature, and the down-scattered neutron yield. As the MRS detection efficiency is determined from first principles, the absolute DT neutron yield is obtained without cross-calibration to other techniques. The MRS primary DT neutron measurements at OMEGA and the NIF are shown to be in excellent agreement with previously established yield diagnostics on OMEGA, and with the newly commissioned nuclear activation diagnostics on the NIF.
Liu, C-H; Lin, S-C; Lin, J-R; Yang, J-T; Chang, Y-J; Chang, C-H; Chang, T-Y; Huang, K-L; Ryu, S-J; Lee, T-H
2014-09-01
Our aim was to investigate the influence of admission dehydration on the discharge outcome in acute ischaemic and hemorrhagic stroke. Between January 2009 and December 2011, 4311 ischaemic and 1371 hemorrhagic stroke patients from the stroke registry of Chang Gung healthcare system were analyzed. The eligible patients were identified according to inclusion/exclusion criteria. In total, 2570 acute ischaemic and 573 acute hemorrhagic stroke patients were finally recruited. According to the blood urea nitrogen (BUN) to creatinine (Cr) ratio (BUN/Cr), these patients were divided into dehydrated (BUN/Cr ≥ 15) and non-dehydrated (BUN/Cr < 15) groups. Demographics, admission costs and discharge outcomes including modified Rankin scale (mRS) and Barthel index (BI) were examined. Data were analyzed using multivariate analysis of two-stage least squares including logistic and linear regression. Acute ischaemic stroke with admission dehydration had higher infection rates (P = 0.006), worse discharge BI (62.8 ± 37.4 vs. 73.4 ± 32.4, P < 0.001, adjusted P < 0.001), worse mRS (2.7 ± 1.6 vs. 2.3 ± 1.5, P < 0.001, adjusted P = 0.009) and higher admission costs (2470.8 ± 3160.8 vs. 1901.2 ± 2046.8 US dollars, P < 0.001, adjusted P = 0.013) than those without dehydration. However, acute hemorrhagic stroke with or without admission dehydration showd no difference in admission costs (P = 0.618) and discharge outcomes (BI, P = 0.058; mRS, P = 0.058). Admission dehydration is associated with worse discharge outcomes and higher admission costs in acute ischaemic stroke but not in hemorrhagic stroke. © 2014 The Author(s) European Journal of Neurology © 2014 EAN.
Dimethyl sulfoxide (DMSO) as a potential contrast agent for brain tumors.
Delgado-Goñi, T; Martín-Sitjar, J; Simões, R V; Acosta, M; Lope-Piedrafita, S; Arús, C
2013-02-01
Dimethyl sulfoxide (DMSO) is commonly used in preclinical studies of animal models of high-grade glioma as a solvent for chemotherapeutic agents. A strong DMSO signal was detected by single-voxel MRS in the brain of three C57BL/6 control mice during a pilot study of DMSO tolerance after intragastric administration. This led us to investigate the accumulation and wash-out kinetics of DMSO in both normal brain parenchyma (n=3 control mice) by single-voxel MRS, and in 12 GL261 glioblastomas (GBMs) by single-voxel MRS (n=3) and MRSI (n=9). DMSO accumulated differently in each tissue type, reaching its highest concentration in tumors: 6.18 ± 0.85 µmol/g water, 1.5-fold higher than in control mouse brain (p<0.05). A faster wash-out was detected in normal brain parenchyma with respect to GBM tissue: half-lives of 2.06 ± 0.58 and 4.57 ± 1.15 h, respectively. MRSI maps of time-course DMSO changes revealed clear hotspots of differential spatial accumulation in GL261 tumors. Additional MRSI studies with four mice bearing oligodendrogliomas (ODs) revealed similar results as in GBM tumors. The lack of T(1) contrast enhancement post-gadolinium (gadopentetate dimeglumine, Gd-DTPA) in control mouse brain and mice with ODs suggested that DMSO was fully able to cross the intact blood-brain barrier in both normal brain parenchyma and in low-grade tumors. Our results indicate a potential role for DMSO as a contrast agent for brain tumor detection, even in those tumors 'invisible' to standard gadolinium-enhanced MRI, and possibly for monitoring heterogeneities associated with progression or with therapeutic response. Copyright © 2012 John Wiley & Sons, Ltd.
Feasibility of the collection of patient-reported outcomes in an ambulatory neurology clinic
Schwamm, Eli; Moura Junior, Valdery; Seitz, Michael P.; Hsu, John; Cole, Andrew J.; Schwamm, Lee H.
2016-01-01
Objective: To determine whether patients could self-report physical and mental health assessments in the waiting room and whether these assessments would be associated with modified Rankin Scale (mRS) and Quality of Life in Epilepsy (QOLIE-10) scores. Methods: We offered iPad-based surveys to consecutive adult neurology patients at check-in to collect patient-reported outcome measures (PROMs). We collected demographic and clinical data on 6,075 patients through survey or administrative claims and PROMs from participating patients. We compared demographic characteristics of participants and nonparticipants and tested associations between physical and mental health scores and mRS and QOLIE-10. Results: Of 6,075 patients seen by neurologists during the study period, 2,992 (49.3%) participated in the survey. Compared to nonparticipating patients, participating patients more often were privately insured (53.5% vs 42.7%, p < 0.01), married (51.5% vs 47.9%, p < 0.01), and seen in general neurology (nonsubspecialty) clinics (53.1% vs 46.6%, p < 0.01) and more likely to report English as their preferred language (50.1% vs 38.4%, p < 0.01). Participating patients had a mean physical health T score of 28.7 (SD 15) and mental health T score of 33 (SD 15), which were 3 and 2 SD worse than the average for the US general population, respectively. Mean T scores in every category of the mRS were different from every other category (n = 232, p < 0.01). Patient Reported Outcomes Measurement Information System-10 T scores were linearly associated with QOLIE-10 scores (n = 202, p < 0.01) Conclusions: Systematic digital collection of PROMs is feasible. Differences among survey participants and nonparticipants highlight the need to develop multilingual measurement tools that may improve collection from vulnerable populations. PMID:27815405
Feasibility of the collection of patient-reported outcomes in an ambulatory neurology clinic.
Moura, Lidia M V R; Schwamm, Eli; Moura Junior, Valdery; Seitz, Michael P; Hsu, John; Cole, Andrew J; Schwamm, Lee H
2016-12-06
To determine whether patients could self-report physical and mental health assessments in the waiting room and whether these assessments would be associated with modified Rankin Scale (mRS) and Quality of Life in Epilepsy (QOLIE-10) scores. We offered iPad-based surveys to consecutive adult neurology patients at check-in to collect patient-reported outcome measures (PROMs). We collected demographic and clinical data on 6,075 patients through survey or administrative claims and PROMs from participating patients. We compared demographic characteristics of participants and nonparticipants and tested associations between physical and mental health scores and mRS and QOLIE-10. Of 6,075 patients seen by neurologists during the study period, 2,992 (49.3%) participated in the survey. Compared to nonparticipating patients, participating patients more often were privately insured (53.5% vs 42.7%, p < 0.01), married (51.5% vs 47.9%, p < 0.01), and seen in general neurology (nonsubspecialty) clinics (53.1% vs 46.6%, p < 0.01) and more likely to report English as their preferred language (50.1% vs 38.4%, p < 0.01). Participating patients had a mean physical health T score of 28.7 (SD 15) and mental health T score of 33 (SD 15), which were 3 and 2 SD worse than the average for the US general population, respectively. Mean T scores in every category of the mRS were different from every other category (n = 232, p < 0.01). Patient Reported Outcomes Measurement Information System-10 T scores were linearly associated with QOLIE-10 scores (n = 202, p < 0.01) CONCLUSIONS: Systematic digital collection of PROMs is feasible. Differences among survey participants and nonparticipants highlight the need to develop multilingual measurement tools that may improve collection from vulnerable populations. © 2016 American Academy of Neurology.
Vice President Pence Tours Jet Propulsion Laboratory
2018-04-28
U.S. Vice President Mike Pence, 3rd from right, tours NASA's Jet Propulsion Laboratory along with his wife Karen, and daughter Charlotte, Saturday, April 28, 2018 in Pasadena, California. Joining the Vice President t and his family on the tour are: UAG Chairman, Admiral (Ret) James Ellis , left, JPL Distinguished Visiting Scientist and Spouse of UAG Chairman James Ellis, Elisabeth Pate-Cornell, behind Mrs. Pence, California Institute of Technology President Thomas Rosenbaum, JPL Director Michael Watkins, and JPL Deputy Director Lt. Gen. (Ret) Larry James, right. Photo Credit: (NASA/Bill Ingalls)
Kang, Bo-Kyeong; Yu, Eun Sil; Lee, Seung Soo; Lee, Youngjoo; Kim, Namkug; Sirlin, Claude B; Cho, Eun Yoon; Yeom, Suk Keu; Byun, Jae Ho; Park, Seong Ho; Lee, Moon-Gyu
2012-06-01
The aims of this study were to assess the confounding effects of hepatic iron deposition, inflammation, and fibrosis on hepatic steatosis (HS) evaluation by magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS) and to assess the accuracies of MRI and MRS for HS evaluation, using histology as the reference standard. In this institutional review board-approved prospective study, 56 patients gave informed consents and underwent chemical-shift MRI and MRS of the liver on a 1.5-T magnetic resonance scanner. To estimate MRI fat fraction (FF), 4 analysis methods were used (dual-echo, triple-echo, multiecho, and multi-interference), and MRS FF was calculated with T2 correction. Degrees of HS, iron deposition, inflammation, and fibrosis were analyzed in liver resection (n = 37) and biopsy (n = 19) specimens. The confounding effects of histology on fat quantification were assessed by multiple linear regression analysis. Using the histologic degree of HS as the reference standard, the accuracies of each method in estimating HS and diagnosing an HS of 5% or greater were determined by linear regression and receiver operating characteristic analyses. Iron deposition significantly confounded estimations of FF by the dual-echo (P < 0.001) and triple-echo (P = 0.033) methods, whereas no histologic feature confounded the multiecho and multi-interference methods or MRS. The MRS (r = 0.95) showed the strongest correlation with histologic degree of HS, followed by the multiecho (r = 0.92), multi-interference (r = 0.91), triple-echo (r = 0.90), and dual-echo (r = 0.85) methods. For diagnosing HS, the areas under the curve tended to be higher for MRS (0.96) and the multiecho (0.95), multi-interference (0.95), and triple-echo (0.95) methods than for the dual-echo method (0.88) (P ≥ 0.13). The multiecho and multi-interference MRI methods and MRS can accurately quantify hepatic fat, with coexisting histologic abnormalities having no confounding effects.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, X; Chen, L; Hensley, H
2014-06-15
Purpose: Magnetic resonance spectroscopic (MRS) imaging may provide important bio-markers to distinguish normal/cancerous prostate tissue. While MRS imaging requires a high uniform magnetic field, the ability of a clinical 1.5T MRI to achieve a comparable MRS signal is of interest for radiation treatment planning/assessment. This study is to evaluate the MRS imaging of a 1.5T clinical MRI for prostate cancers by comparing with a small animal 7T MRS scanner. Methods: A tumor model was developed by implanting LNCaP tumor cells in nude mice prostates. Tumor was monitored 3 weeks after implantation using MRI, and MRS imaging was performed on themore » tumor area when the tumor reached around 1cm in diameter. The 1.5T GE clinical MR scanner and the 7T Bruker small animal MR scanner were used for each mouse. MR spectrums acquired with these scanners were analyzed and compared. The signals of Choline and Citrate were considered. Results: The prostate tumor MR spectrum under the 1.5T clinical MRI showed a similar spectrum pattern to that acquired using the 7T animal MRI. The Choline signal (3.2ppm) is clear and there is no clear peak for Citrate (2.6ppm). However, the signal magnitude for Choline is not dominant compared to the background signal under 1.5T MRI. Typical cancerous prostate tissue MR spectrum with an increased Choline signal and a reduced Citrate signal was observed. In addition, signal variation is noticeable between repeated spectrum scans. The average of these scans showed a comparable and consistent spectrum to those under 7T MRI. Conclusion: The clinical 1.5T MRI is able to acquire a MR spectrum for prostate cancer comparable to those acquired using a dedicated 7T MRS scanner. However, to achieve a consistent and reliable spectrum, multiple repeated scans were necessary to get a statistical result and reduce the noise-induced artifact. This work was supported in part by the National Cancer Institute Grant R21 CA131979 and R01CA172638.« less
Jacobson, K A; Kim, Y C; King, B F
2000-07-03
1,4-Dihydropyridines are regarded as privileged structures for drug design, i.e. they tend to bind to a wide variety of receptor sites. We have shown that upon appropriate manipulation of the substituent groups on a 1,4-dihydropyridine template, high affinity and selectivity for the A(3) subtype of adenosine receptors ('P1 receptors') may be attained. In the present study we have begun to extend this approach to P2 receptors which are activated by ATP and other nucleotides. Nicardipine, a representative dihydropyridine, used otherwise as an L-type calcium channel blocker, was shown to be an antagonist at recombinant rat P2X(2) (IC(50)=25 microM) and P2X(4) (IC(50) approximately 220 microM) receptors expressed in Xenopus oocytes. Thus, this class of compounds represents a suitable lead for enhancement of affinity through chemical synthesis. In an attempt to modify the 1,4-dihydropyridine structure with a predicted P2 receptor recognition moiety, we have replaced one of the ester groups with a negatively charged phosphonate group. Several 4-phenyl-5-phosphonato-1,4-dihydropyridine derivatives, MRS 2154 (2, 6-dimethyl), MRS 2155 (6-methyl-2-phenyl), and MRS 2156 (2-methyl-6-phenyl), were synthesized through three component condensation reactions. These derivatives were not pure antagonists of the effects of ATP at P2X(2) receptors, rather were either inactive (MRS 2156) or potentiated the effects of ATP in a concentration-dependent manner (MRS 2154 in the 0.3-10 microM range and MRS 2155 at >1 microM). Antagonism of the effects of ATP at P2X(2) receptor superimposed on the potentiation was also observed at >10 microM (MRS 2154) or 0.3-1 microM (MRS 2155). Thus, while a conventional dihydropyridine, nicardipine, was found to antagonize rat P2X(2) receptors ninefold more potently than P2X(4) receptors, the effects of novel, anionic 5-phosphonate analogues at the receptor were more complex.
Tiwari, Pallavi; Kurhanewicz, John; Viswanath, Satish; Sridhar, Akshay; Madabhushi, Anant
2011-01-01
Rationale and Objectives To develop a computerized data integration framework (MaWERiC) for quantitatively combining structural and metabolic information from different Magnetic Resonance (MR) imaging modalities. Materials and Methods In this paper, we present a novel computerized support system that we call Multimodal Wavelet Embedding Representation for data Combination (MaWERiC) which (1) employs wavelet theory and dimensionality reduction for providing a common, uniform representation of the different imaging (T2-w) and non-imaging (spectroscopy) MRI channels, and (2) leverages a random forest classifier for automated prostate cancer detection on a per voxel basis from combined 1.5 Tesla in vivo MRI and MRS. Results A total of 36 1.5 T endorectal in vivo T2-w MRI, MRS patient studies were evaluated on a per-voxel via MaWERiC, using a three-fold cross validation scheme across 25 iterations. Ground truth for evaluation of the results was obtained via ex-vivo whole-mount histology sections which served as the gold standard for expert radiologist annotations of prostate cancer on a per-voxel basis. The results suggest that MaWERiC based MRS-T2-w meta-classifier (mean AUC, μ = 0.89 ± 0.02) significantly outperformed (i) a T2-w MRI (employing wavelet texture features) classifier (μ = 0.55± 0.02), (ii) a MRS (employing metabolite ratios) classifier (μ= 0.77 ± 0.03), (iii) a decision-fusion classifier, obtained by combining individual T2-w MRI and MRS classifier outputs (μ = 0.85 ± 0.03) and (iv) a data combination scheme involving combination of metabolic MRS and MR signal intensity features (μ = 0.66± 0.02). Conclusion A novel data integration framework, MaWERiC, for combining imaging and non-imaging MRI channels was presented. Application to prostate cancer detection via combination of T2-w MRI and MRS data demonstrated significantly higher AUC and accuracy values compared to the individual T2-w MRI, MRS modalities and other data integration strategies. PMID:21960175
Bucy, Daniel S; Brown, Mark S; Bielefeldt-Ohmann, Helle; Thompson, Jesse; Bachand, Annette M; Morges, Michelle; Elder, John H; Vandewoude, Sue; Kraft, Susan L
2011-08-01
HIV infection results in a highly prevalent syndrome of cognitive and motor disorders designated as HIV-associated dementia (HAD). Neurologic dysfunction resembling HAD has been documented in cats infected with strain PPR of the feline immunodeficiency virus (FIV), whereas another highly pathogenic strain (C36) has not been known to cause neurologic signs. Animals experimentally infected with equivalent doses of FIV-C36 or FIV-PPR, and uninfected controls were evaluated by magnetic resonance diffusion-weighted imaging (DW-MRI) and spectroscopy (MRS) at 17.5-18 weeks post-infection, as part of a study of viral clade pathogenesis in FIV-infected cats. The goals of the MR imaging portion of the project were to determine whether this methodology was capable of detecting early neuropathophysiology in the absence of outward manifestation of neurological signs and to compare the MR imaging results for the two viral strains expected to have differing degrees of neurologic effects. We hypothesized that there would be increased diffusion, evidenced by the apparent diffusion coefficient as measured by DW-MRI, and altered metabolite ratios measured by MRS, in the brains of FIV-PPR-infected cats relative to C36-infected cats and uninfected controls. Increased apparent diffusion coefficients were seen in the white matter, gray matter, and basal ganglia of both the PPR and C36-infected (asymptomatic) cats. Thalamic MRS metabolite ratios did not differ between groups. The equivalently increased diffusion by DW-MRI suggests similar indirect neurotoxicity mechanisms for the two viral genotypes. DW-MRI is a sensitive tool to detect neuropathophysiological changes in vivo that could be useful during longitudinal studies of FIV.
Koo, Ja Seung; Kim, Siwon; Park, Vivian Youngjean; Kim, Eun-Kyung; Kim, Suhkmann; Kim, Min Jung
2017-01-01
Estrogen receptor (ER)-positive breast cancers overall have a good prognosis, however, some patients suffer relapses and do not respond to endocrine therapy. The purpose of this study was to determine whether there are any correlations between high-resolution magic angle spinning (HR-MAS) magnetic resonance spectroscopy (MRS) metabolic profiles of core needle biopsy (CNB) specimens and the molecular markers currently used in patients with ER-positive breast cancers. The metabolic profiling of CNB samples from 62 ER-positive cancers was performed by HR-MAS MRS. Metabolic profiles were compared according to human epidermal growth factor receptor 2 (HER2) and Ki-67 status, and luminal type, using the Mann-Whitney test. Multivariate analysis was performed with orthogonal projections to latent structure-discriminant analysis (OPLS-DA). In univariate analysis, the HER2-positive group was shown to have higher levels of glycine and glutamate, compared to the HER2-negative group (P<0.01, and P <0.01, respectively). The high Ki-67 group showed higher levels of glutamate than the low Ki-67 group without statistical significance. Luminal B cancers showed higher levels of glycine (P=0.01) than luminal A cancers. In multivariate analysis, the OPLS-DA models built with HR-MAS MR metabolic profiles showed visible discrimination between the subgroups according to HER2 and Ki-67 status, and luminal type. This study showed that the metabolic profiles of CNB samples assessed by HR-MAS MRS can be used to detect potential prognostic biomarkers as well as to understand the difference in metabolic mechanism among subtypes of ER-positive breast cancer. PMID:28969000
Ischemic strokes in Pakistan: observations from the national acute ischemic stroke database.
Khealani, Bhojo A; Khan, Maria; Tariq, Muhammad; Malik, Abdul; Siddiqi, Alam I; Awan, Safia; Wasay, Mohammad
2014-07-01
The objective of this study was to establish a multicenter ischemic stroke registry, first of its kind in Pakistan, to provide insight into the epidemiology, subtypes, and risk factors of ischemic strokes in this country. Four academic centers (3 urban and 1 rural) participated in this project. The inclusion criteria for subjects included adults (>14 years) with acute neurologic deficit, consistent with clinical diagnosis of ischemic stroke and supported by neuroimaging. Data were available for 874 subjects. Mean age of the subjects was 59.7 years, 60.5% were males, and 18% were young. Large vessel strokes were the most common subtype found in 31.7% subjects, followed by small vessel disease (25.7%) and cardioembolic strokes (10.4%). Almost 32% subjects had ill-defined etiology for their ischemic stroke. Dyslipidemia was a most common risk factor present in 83% patients. Data related to in-hospital complications were available for 808 subjects, of which 233 complications were recorded. Pneumonia was the most common of these seen in 105 (13%) subjects, followed by urinary tract infection (7.2%). Outcome at discharge was recorded for 697 subjects. Ninety-two had died during their hospital stay (13.2%). Only 36% subjects had a favorable outcome at discharge defined as a modified Rankin Scale (mRS) score of 2 or less. A total of 446 of 697 subjects had poor outcome at discharge (defined as an mRS score≥3). Hypertension and dyslipidemia were the most common risk factors and large vessel atherosclerosis was the most common stroke etiology. Elderly patients were significantly more likely to have in-hospital complications, die during their hospital stay, and have a higher mRS score at discharge. Copyright © 2014 National Stroke Association. Published by Elsevier Inc. All rights reserved.
View looking south of first floor bedroom of Mrs. Perry ...
View looking south of first floor bedroom of Mrs. Perry (Jessie) Belmont/Right Worthy Grand Secretary's Living Room - Perry Belmont House, 1618 New Hampshire Avenue, NW, Washington, District of Columbia, DC
Hayashi, Norio; Miyati, Tosiaki; Minami, Takashi; Takeshita, Yumie; Ryu, Yasuji; Matsuda, Tsuyoshi; Ohno, Naoki; Hamaguchi, Takashi; Kato, Kenichiro; Takamura, Toshinari; Matsui, Osamu
2013-01-01
The focus of this study was on the investigation of the accuracy of the fat fraction of the liver by use of single-breath-holding magnetic resonance spectroscopy (MRS) with T (2) correction. Single-voxel proton MRS was performed with several TE values, and the fat fraction was determined with and without T (2) correction. MRS was also performed with use of the point-resolved spectroscopy sequence in single breath holding. The T (2) values of both water and fat were determined separately at the same time, and the effect of T (2) on the fat fraction was corrected. In addition, MRS-based fat fractions were compared with the degree of hepatic steatosis (HS) by liver biopsy in human subjects. With T (2) correction, the MRI-derived fat fractions were in good agreement with the fat fractions in all phantoms, but the fat fractions were overestimated without T (2) correction. R (2) values were in good agreement with the preset iron concentrations in the phantoms. The MRI-derived fat fraction was well correlated with the degree of HS. Iron deposited in the liver affects the signal strength when proton MRS is used for detection of the fat signal in the liver. However, the fat signal can be evaluated more accurately when the T (2) correction is applied. Breath-holding MRS minimizes the respiratory motion, and it can be more accurate in the quantification of the hepatic fat fraction.
Broom, Kerry A; Anthony, Daniel C; Lowe, John P; Griffin, Julian L; Scott, Helen; Blamire, Andrew M; Styles, Peter; Perry, V Hugh; Sibson, Nicola R
2007-06-01
Prion diseases are fatal chronic neurodegenerative diseases. Previous qualitative magnetic resonance imaging (MRI) and spectroscopy (MRS) studies report conflicting results in the symptomatic stages of the disease, but little work has been carried out during the earlier stages of the disease. Here we have used the murine ME7 model of prion disease to quantitatively investigate MRI and MRS changes during the period prior to the onset of overt clinical signs (20+ weeks) and have correlated these with pathological and behavioural abnormalities. Using in vivo MRI, at the later stages of the preclinical period (18 weeks) the diffusion of tissue water was significantly reduced, coinciding with significant microglial activation and behavioural hyperactivity. Using in vivo MRS, we found early (12 weeks) decreases in the ratio of N-acetyl aspartate to both choline (NAA/Cho) and creatine (NAA/Cr) in the thalamus and hippocampus, which were associated with early behavioural deficits. Ex vivo MRS of brain extracts confirmed and extended these findings, showing early (8-12 weeks) decreases in both the neuronal metabolites NAA and glutamate, and the metabolic metabolites lactate and glucose. Increases in the glial metabolite myo-inositol were observed at later stages when microglial and astrocyte activation is substantial. These changes in MRI and MRS signals, which precede overt clinical signs of disease, could provide insights into the pathogenesis of this disease and may enable early detection of pathology.
Gerrick, Elias R; Barbier, Thibault; Chase, Michael R; Xu, Raylin; François, Josie; Lin, Vincent H; Szucs, Matthew J; Rock, Jeremy M; Ahmad, Rushdy; Tjaden, Brian; Livny, Jonathan; Fortune, Sarah M
2018-06-19
One key to the success of Mycobacterium tuberculosis as a pathogen is its ability to reside in the hostile environment of the human macrophage. Bacteria adapt to stress through a variety of mechanisms, including the use of small regulatory RNAs (sRNAs), which posttranscriptionally regulate bacterial gene expression. However, very little is currently known about mycobacterial sRNA-mediated riboregulation. To date, mycobacterial sRNA discovery has been performed primarily in log-phase growth, and no direct interaction between any mycobacterial sRNA and its targets has been validated. Here, we performed large-scale sRNA discovery and expression profiling in M. tuberculosis during exposure to five pathogenically relevant stresses. From these data, we identified a subset of sRNAs that are highly induced in multiple stress conditions. We focused on one of these sRNAs, ncRv11846, here renamed mycobacterial regulatory sRNA in iron (MrsI). We characterized the regulon of MrsI and showed in mycobacteria that it regulates one of its targets, bfrA , through a direct binding interaction. MrsI mediates an iron-sparing response that is required for optimal survival of M. tuberculosis under iron-limiting conditions. However, MrsI is induced by multiple host-like stressors, which appear to trigger MrsI as part of an anticipatory response to impending iron deprivation in the macrophage environment. Copyright © 2018 the Author(s). Published by PNAS.
Shutter, Lori; Tong, Karen A; Holshouser, Barbara A
2004-12-01
Proton magnetic resonance spectroscopy (MRS) is being used to evaluate individuals with acute traumatic brain injury and several studies have shown that changes in certain brain metabolites (N-acetylaspartate, choline) are associated with poor neurologic outcomes. The majority of previous MRS studies have been obtained relatively late after injury and none have examined the role of glutamate/ glutamine (Glx). We conducted a prospective MRS study of 42 severely injured adults to measure quantitative metabolite changes early (7 days) after injury in normal appearing brain. We used these findings to predict long-term neurologic outcome and to determine if MRS data alone or in combination with clinical outcome variables provided better prediction of long-term outcomes. We found that glutamate/glutamine (Glx) and choline (Cho) were significantly elevated in occipital gray and parietal white matter early after injury in patients with poor long-term (6-12-month) outcomes. Glx and Cho ratios predicted long-term outcome with 94% accuracy and when combined with the motor Glasgow Coma Scale score provided the highest predictive accuracy (97%). Somatosensory evoked potentials were not as accurate as MRS data in predicting outcome. Elevated Glx and Cho are more sensitive indicators of injury and predictors of poor outcome when spectroscopy is done early after injury. This may be a reflection of early excitotoxic injury (i.e., elevated Glx) and of injury associated with membrane disruption (i.e., increased Cho) secondary to diffuse axonal injury.
Youssef, Doaa Mohammed; Mohamed, Ahmed Hosny; Kamel Attia, Wafaa Mahmoud; Mohammad, Faten Fawzy; El Fatah, Nelly Rafaat Abd; Elshal, Amal Saeed
2017-06-16
Many studies described Impaired intelligence, attention, memory and executive function in patients with chronic kidney disease (CKD) dialyzed and non-dialyzed, but there is still lacking the early and sensitive method of detection of these deficits. The purpose of this study is to investigate relation between the brain metabolic alteration [measured by magnetic resonance spectroscopy (MRS)] and cognitive dysfunction in CKD children (detected by psychometric analysis). One hundred and forty patients with CKD were included [ 40 patients with stage 5 CKD on dialysis, 30 patients with stage 4 to 5 CKD without dialysis, and 70 patients with stage 1 to 3 CKD]. All patients with previous neurological disorders were excluded. Conventional MRI, MRS and psychometric assessment by using Wechsler intelligence scale for children third edition was done in all subjects. We found a significant negative correlation between MRS abnormalities and Wechsler IQ Test scores. But there was a significantly positive correlation between the CKD stages and MRS abnormalities in patients with CKD and negative significant correlation between CKD stages and Wechsler IQ test scores in patients with CKD. There were correlations between "the electrolyte disturbance, blood hemoglobin and hypertension" and "the CKD staging, cognitive functions IQ scores and MRS parameter changes". We concluded that both MRS and psychometric tests are sensitive methods for detection of cognitive function affection in CKD children, particularly in dialyzed group and these findings appears before the clinical diagnosis. This article is protected by copyright. All rights reserved.
Orłowski, Mikołaj; Janik, Michał R; Paśnik, Krzysztof; Jędrzejewski, Emil
2015-07-01
The most popular scale to stratify the postoperative risk is the Obesity Surgery Mortality Risk Score (OS-MRS). The design and ease of interpretation make the scale a potential tool for clinical use. To evaluate the usefulness of the OS-MRS scale in the enrollment of patients for laparoscopic bariatric procedures, including laparoscopic sleeve gastrectomy (LSG) and laparoscopic Roux-en-Y gastric bypass (LRYGB). The medical records of patients who underwent LSG or LRYGB due to obesity between January 2010 and December 2010 were reviewed retrospectively. The decision of choosing the surgical procedure was made on the basis of OS-MRS risk category. The primary endpoint of this study was the 90-day mortality, and the secondary endpoint was the presence of major complications. There were 107 patients including 66 women and 41 men. The OS-MRS classes were A (48%), B (47%) and C (5%). The LSG was applied to patients with higher body mass index and to patients of class C. The secondary endpoints occurred in 6 patients, distributed in 10% of class A, 2% of class B and 0% of class C patients (p < 0.05). In 5 of 6 cases the endpoint was observed after LRYGB. Fatal cases were not observed. The OS-MRS can be a useful clinical tool for choosing the appropriate laparoscopic bariatric procedure, depending on the risk of postoperative complications. Low risk of postoperative complications should not lower the watchfulness of the surgeon.
Age Related Changes in Metabolite Concentrations in the Normal Spinal Cord
Abdel-Aziz, Khaled; Solanky, Bhavana S.; Yiannakas, Marios C.; Altmann, Daniel R.; Wheeler-Kingshott, Claudia A. M.; Thompson, Alan J.; Ciccarelli, Olga
2014-01-01
Magnetic resonance spectroscopy (MRS) studies have previously described metabolite changes associated with aging of the healthy brain and provided insights into normal brain aging that can assist us in differentiating age-related changes from those associated with neurological disease. The present study investigates whether age-related changes in metabolite concentrations occur in the healthy cervical spinal cord. 25 healthy volunteers, aged 23–65 years, underwent conventional imaging and single-voxel MRS of the upper cervical cord using an optimised point resolved spectroscopy sequence on a 3T Achieva system. Metabolite concentrations normalised to unsuppressed water were quantified using LCModel and associations between age and spinal cord metabolite concentrations were examined using multiple regressions. A linear decline in total N-Acetyl-aspartate concentration (0.049 mmol/L lower per additional year of age, p = 0.010) and Glutamate-Glutamine concentration (0.054 mmol/L lower per additional year of age, p = 0.002) was seen within our sample age range, starting in the early twenties. The findings suggest that neuroaxonal loss and/or metabolic neuronal dysfunction, and decline in glutamate-glutamine neurotransmitter pool progress with aging. PMID:25310093
Stovell, Matthew G.; Yan, Jiun-Lin; Sleigh, Alison; Mada, Marius O.; Carpenter, T. Adrian; Hutchinson, Peter J. A.; Carpenter, Keri L. H.
2017-01-01
Traumatic brain injury (TBI) triggers a series of complex pathophysiological processes. These include abnormalities in brain energy metabolism; consequent to reduced tissue pO2 arising from ischemia or abnormal tissue oxygen diffusion, or due to a failure of mitochondrial function. In vivo magnetic resonance spectroscopy (MRS) allows non-invasive interrogation of brain tissue metabolism in patients with acute brain injury. Nuclei with “spin,” e.g., 1H, 31P, and 13C, are detectable using MRS and are found in metabolites at various stages of energy metabolism, possessing unique signatures due to their chemical shift or spin–spin interactions (J-coupling). The most commonly used clinical MRS technique, 1H MRS, uses the great abundance of hydrogen atoms within molecules in brain tissue. Spectra acquired with longer echo-times include N-acetylaspartate (NAA), creatine, and choline. NAA, a marker of neuronal mitochondrial activity related to adenosine triphosphate (ATP), is reported to be lower in patients with TBI than healthy controls, and the ratio of NAA/creatine at early time points may correlate with clinical outcome. 1H MRS acquired with shorter echo times produces a more complex spectrum, allowing detection of a wider range of metabolites.31 P MRS detects high-energy phosphate species, which are the end products of cellular respiration: ATP and phosphocreatine (PCr). ATP is the principal form of chemical energy in living organisms, and PCr is regarded as a readily mobilized reserve for its replenishment during periods of high utilization. The ratios of high-energy phosphates are thought to represent a balance between energy generation, reserve and use in the brain. In addition, the chemical shift difference between inorganic phosphate and PCr enables calculation of intracellular pH.13 C MRS detects the 13C isotope of carbon in brain metabolites. As the natural abundance of 13C is low (1.1%), 13C MRS is typically performed following administration of 13C-enriched substrates, which permits tracking of the metabolic fate of the infused 13C in the brain over time, and calculation of metabolic rates in a range of biochemical pathways, including glycolysis, the tricarboxylic acid cycle, and glutamate–glutamine cycling. The advent of new hyperpolarization techniques to transiently boost signal in 13C-enriched MRS in vivo studies shows promise in this field, and further developments are expected. PMID:28955291
Lee, Yun-Jin; Cheon, Chong Kun; Yeon, Gyu Min; Kim, Young Mi; Nam, Sang Ook
2014-05-01
Melkersson-Rosenthal syndrome (MRS) is a rare disorder of unknown cause. The classical triad of MRS is orofacial edema, recurrent facial paralysis, and a fissured tongue. We present a 9-year-old girl with a recurrent peripheral facial paralysis. She experienced the first episode of a peripheral facial paralysis on the same side without orofacial swelling and lingua plicata 1 year ago. She was diagnosed with Hashimoto thyroiditis 9 months earlier, as confirmed by an endocrinologic investigation. While the patient was hospitalized with recurrent facial paralysis, we found that serum levels of free thyroxine (1.3 ng/dL) and thyrotropin (0.4 uIU/mL) were within normal range, but the level of antithyroperoxidase antibodies (772.0 IU/mL) was very increased. She had been taking an oral prednisolone orally for 2 weeks. At the 1-month follow-up, the patient's symptoms had completely disappeared. The possible correlation between MRS and autoimmune disorders has been documented in only one report, which described an adult with autoimmune thyroiditis (Hashimoto thyroiditis) and MRS. We suggest that the co-occurrence of MRS and Hashimoto thyroiditis is not coincidental but linked to autoimmunity. Copyright © 2014 Elsevier Inc. All rights reserved.
Modulated Raman spectroscopy for enhanced identification of bladder tumor cells in urine samples.
Canetta, Elisabetta; Mazilu, Michael; De Luca, Anna Chiara; Carruthers, Antonia E; Dholakia, Kishan; Neilson, Sam; Sargeant, Harry; Briscoe, Tina; Herrington, C Simon; Riches, Andrew C
2011-03-01
Standard Raman spectroscopy (SRS) is a noninvasive technique that is used in the biomedical field to discriminate between normal and cancer cells. However, the presence of a strong fluorescence background detracts from the use of SRS in real-time clinical applications. Recently, we have reported a novel modulated Raman spectroscopy (MRS) technique to extract the Raman spectra from the background. In this paper, we present the first application of MRS to the identification of human urothelial cells (SV-HUC-1) and bladder cancer cells (MGH) in urine samples. These results are compared to those obtained by SRS. Classification using the principal component analysis clearly shows that MRS allows discrimination between Raman spectra of SV-HUC-1 and MGH cells with high sensitivity (98%) and specificity (95%). MRS is also used to distinguish between SV-HUC-1 and MGH cells after exposure to urine for up to 6 h. We observe a marked change in the MRS of SV-HUC-1 and MGH cells with time in urine, indicating that the conditions of sample collection will be important for the application of this methodology to clinical urine samples.
The good, the bad and the ugly of marine reserves for fishery yields
De Leo, Giulio A.; Micheli, Fiorenza
2015-01-01
Marine reserves (MRs) are used worldwide as a means of conserving biodiversity and protecting depleted populations. Despite major investments in MRs, their environmental and social benefits have proven difficult to demonstrate and are still debated. Clear expectations of the possible outcomes of MR establishment are needed to guide and strengthen empirical assessments. Previous models show that reserve establishment in overcapitalized, quota-based fisheries can reduce both catch and population abundance, thereby negating fisheries and even conservation benefits. By using a stage-structured, spatially explicit stochastic model, we show that catches under quota-based fisheries that include a network of MRs can exceed maximum sustainable yield (MSY) under conventional quota management if reserves provide protection to old, large spawners that disproportionally contribute to recruitment outside the reserves. Modelling results predict that the net fishery benefit of MRs is lost when gains in fecundity of old, large individuals are small, is highest in the case of sedentary adults with high larval dispersal, and decreases with adult mobility. We also show that environmental variability may mask fishery benefits of reserve implementation and that MRs may buffer against collapse when sustainable catch quotas are exceeded owing to stock overestimation or systematic overfishing. PMID:26460129
1. Historic American Buildings Survey Photographer Unknown. Furnished by Mrs ...
1. Historic American Buildings Survey Photographer Unknown. Furnished by Mrs Mecia, Tombstone, Arizona. Date Unknown GENERAL VIEW MAIN CHURCH (SOUTHEAST ELEVATION). - San Xavier del Bac Mission, Mission Road, Tucson, Pima County, AZ
Photocopy of a postcard, circa 1910 from Mr. and Mrs. ...
Photocopy of a postcard, circa 1910 from Mr. and Mrs. Buford Buoy, Chinton, Missouri) SOUTH AND EAST FACADES BEFORE ALTERATION OF DOORS - Bethlehem Baptist Church, Route AA & 35 vicinity, Clinton, Henry County, MO
Maruyama, Kenji; Uchiyama, Shinichiro; Shiga, Tsuyoshi; Iijima, Mutsumi; Ishizuka, Kentaro; Hoshino, Takao; Kitagawa, Kazuo
2017-01-01
Background Since stroke patients with nonvalvular atrial fibrillation (NVAF) have poor outcomes in general, the prediction of outcomes following discharge is of utmost concern for these patients. We previously reported that brain natriuretic peptide (BNP) levels were significantly higher in NVAF patients with larger infarcts, higher modified Rankin Scale (mRS) score, and higher CHADS2 score. In the present study, we evaluated an array of variables, including BNP, in order to determine significant predictors for functional outcome in patients with NVAF after acute ischemic stroke (AIS). Methods A total of 615 consecutive patients with AIS within 48 h of symptom onset, admitted to our hospital between April 2010 and October 2015, were retrospectively searched. Among these patients, we enrolled consecutive patients with NVAF. We evaluated the mRS score 3 months after onset of stroke and investigated associations between mRS score and the following clinical and echocardiographic variables. Categorical variables included male sex, current smoking, alcohol intake, hypertension, diabetes mellitus, dyslipidemia, coronary artery disease, peripheral artery disease, use of antiplatelet drugs, anticoagulants, or tissue plasminogen activator (tPA), and infarct size. Continuous variables included age, systolic blood pressure (SBP), diastolic blood pressure, hemoglobin, creatinine, D-dimer, brain natriuretic peptide (BNP), left atrial diameter, left ventricular ejection fraction (EF), and early mitral inflow velocity/diastolic mitral annular velocity (E/e’). We also analyzed the association of prestroke CHADS2, CHA2DS2-VASc, and R2CHADS2 scores, and National Institutes of Health Stroke Scale (NIHSS) score on admission with mRS score 3 months after the onset of stroke. Patients were classified into 2 groups according to mRS score: an mRS score ≤2 was defined as good outcome, an mRS score ≥3 was defined as poor outcome. To clarify the correlations between categorical or continuous variables and mRS score, uni- and multivariate logistic regression models using the stepwise variable selection method were applied. Results Among 157 patients with NVAF after AIS, 63.7% were male and the mean age was 75.9 years. In univariate regression analysis, poor outcome (mRS score ≥3) was associated with use of tPA, infarct size, age, SBP, BNP, EF, and NIHSS score. In multivariate regression analysis, BNP levels (odds ratio [OR] 6.40; 95% confidence interval [CI] 1.26–32.43; p = 0.0235) and NIHSS score (OR 2.87; 95% CI 1.84–4.47; p < 0.001) were significantly associated with poor outcome (mRS score ≥3) after adjusting for use of tPA, infarct size, age, BNP, EF, and NIHSS score. Conclusions Apart from NIHSS score, BNP was a very useful predictor for long-term outcomes of patients with NVAF after AIS. PMID:28253498
Jazayeri, Darius; Teich, Jonathan M; Ball, Ellen; Nankubuge, Patricia Alexandra; Rwebembera, Job; Wing, Kevin; Sesay, Alieu Amara; Kanter, Andrew S; Ramos, Glauber D; Walton, David; Cummings, Rachael; Checchi, Francesco; Fraser, Hamish S
2017-01-01
Background Stringent infection control requirements at Ebola treatment centers (ETCs), which are specialized facilities for isolating and treating Ebola patients, create substantial challenges for recording and reviewing patient information. During the 2014-2016 West African Ebola epidemic, paper-based data collection systems at ETCs compromised the quality, quantity, and confidentiality of patient data. Electronic health record (EHR) systems have the potential to address such problems, with benefits for patient care, surveillance, and research. However, no suitable software was available for deployment when large-scale ETCs opened as the epidemic escalated in 2014. Objective We present our work on rapidly developing and deploying OpenMRS-Ebola, an EHR system for the Kerry Town ETC in Sierra Leone. We describe our experience, lessons learned, and recommendations for future health emergencies. Methods We used the OpenMRS platform and Agile software development approaches to build OpenMRS-Ebola. Key features of our work included daily communications between the development team and ground-based operations team, iterative processes, and phased development and implementation. We made design decisions based on the restrictions of the ETC environment and regular user feedback. To evaluate the system, we conducted predeployment user questionnaires and compared the EHR records with duplicate paper records. Results We successfully built OpenMRS-Ebola, a modular stand-alone EHR system with a tablet-based application for infectious patient wards and a desktop-based application for noninfectious areas. OpenMRS-Ebola supports patient tracking (registration, bed allocation, and discharge); recording of vital signs and symptoms; medication and intravenous fluid ordering and monitoring; laboratory results; clinician notes; and data export. It displays relevant patient information to clinicians in infectious and noninfectious zones. We implemented phase 1 (patient tracking; drug ordering and monitoring) after 2.5 months of full-time development. OpenMRS-Ebola was used for 112 patient registrations, 569 prescription orders, and 971 medication administration recordings. We were unable to fully implement phases 2 and 3 as the ETC closed because of a decrease in new Ebola cases. The phase 1 evaluation suggested that OpenMRS-Ebola worked well in the context of the rollout, and the user feedback was positive. Conclusions To our knowledge, OpenMRS-Ebola is the most comprehensive adaptable clinical EHR built for a low-resource setting health emergency. It is designed to address the main challenges of data collection in highly infectious environments that require robust infection prevention and control measures and it is interoperable with other electronic health systems. Although we built and deployed OpenMRS-Ebola more rapidly than typical software, our work highlights the challenges of having to develop an appropriate system during an emergency rather than being able to rapidly adapt an existing one. Lessons learned from this and previous emergencies should be used to ensure that a set of well-designed, easy-to-use, pretested health software is ready for quick deployment in future. PMID:28827211
McTavish, Jill R; Kimber, Melissa; Devries, Karen; Colombini, Manuela; MacGregor, Jennifer C D; Wathen, C Nadine; Agarwal, Arnav; MacMillan, Harriet L
2017-10-16
To systematically search for research about the effectiveness of mandatory reporting of child maltreatment and to synthesise qualitative research that explores mandated reporters' (MRs) experiences with reporting. As no studies assessing the effectiveness of mandatory reporting were retrieved from our systematic search, we conducted a meta-synthesis of retrieved qualitative research. Searches in Medline (Ovid), Embase, PsycINFO, Cumulative Index to Nursing and Allied Health Literature, Sociological Abstracts, Education Resources Information Center, Criminal Justice Abstracts and Cochrane Library yielded over 6000 citations, which were deduplicated and then screened by two independent reviewers. English-language, primary qualitative studies that investigated MRs' experiences with reporting of child maltreatment were included. Critical appraisal involved a modified checklist from the Critical Appraisal Skills Programme and qualitative meta-synthesis was used to combine results from the primary studies. All healthcare and social-service settings implicated by mandatory reporting laws were included. Included studies crossed nine high-income countries (USA, Australia, Sweden, Taiwan, Canada, Norway, Finland, Israel and Cyprus) and three middle-income countries (South Africa, Brazil and El Salvador). The studies represent the views of 1088 MRs. Factors that influence MRs' decision to report and MRs' views towards and experiences with mandatory reporting of child maltreatment. Forty-four articles reporting 42 studies were included. Findings indicate that MRs struggle to identify and respond to less overt forms of child maltreatment. While some articles (14%) described positive experiences MRs had with the reporting process, negative experiences were reported in 73% of articles and included accounts of harm to therapeutic relationships and child death following removal from their family of origin. The findings of this meta-synthesis suggest that there are many potentially harmful experiences associated with mandatory reporting and that research on the effectiveness of this process is urgently needed. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Kise, Yoshitaka; Chikui, Toru; Yamashita, Yasuo; Kobayashi, Koji; Yoshiura, Kazunori
2017-08-01
To estimate the fat fraction (FF) in the salivary glands (SGs) by the mDIXON method and the 1 H-MR spectroscopy (MRS) method, and to compare the results. 16 healthy volunteers were enrolled. mDIXON Quant and MRS (point-resolved spectroscopy: PRESS) with a single TE were employed to measure the FF in the parotid gland (PG) and submandibular gland (SMG). Multiple TEs were applied in 10 volunteers to correct for T 2 decay. In addition, we assumed that the 1.3 ppm peak accounted for 60% of the total fat peak and estimated the FF (MRS all) as a gold standard. On mDIXON Quant images, volumes of interest were set on the bilateral SGs and we obtained the FF (mDIXON) of each volume of interest. There was a strong correlation between the results of the mDIXON Quant method and the MRS (single TE) method (R 2 = 0.960, slope = 0.900). Using PRESS with multiple TEs, there was also a strong correlation between FF (mDIXON) and FF (MRS all) (R 2 = 0.963, slope = 1.18). FF (MRS all) was 24.9±12.7% in the PG and 4.5±3.0% in the SMG, while FF (mDIXON) was 29.4±16.2% in the PG and 6.4±4.7% in the SMG. There were no significant differences between the two methods, but the Bland-Altman plot showed that FF (mDIXON) was slightly larger than FF (MRS all) for small FF areas. The mDIXON Quant method could be clinically useful for evaluating the FF of SGs, but the absolute values need careful interpretation. Advance in knowledge: This study suggested the potential clinical usefulness of the mDIXON Quant method for the SGs.
Traussnigg, Stefan; Kienbacher, Christian; Gajdošík, Martin; Valkovič, Ladislav; Halilbasic, Emina; Stift, Judith; Rechling, Christian; Hofer, Harald; Steindl-Munda, Petra; Ferenci, Peter; Wrba, Fritz; Trattnig, Siegfried; Krššák, Martin; Trauner, Michael
2017-10-01
With the rising prevalence of non-alcoholic fatty liver disease (NAFLD) and steatohepatitis (NASH) non-invasive tools obtaining pathomechanistic insights to improve risk stratification are urgently needed. We therefore explored high- and ultra-high-field magnetic resonance spectroscopy (MRS) to obtain novel mechanistic and diagnostic insights into alterations of hepatic lipid, cell membrane and energy metabolism across the spectrum of NAFLD. MRS and liver biopsy were performed in 30 NAFLD patients with NAFL (n=8) or NASH (n=22). Hepatic lipid content and composition were measured using 3-Tesla proton ( 1 H)-MRS. 7-Tesla phosphorus ( 31 P)-MRS was applied to determine phosphomonoester (PME) including phosphoethanolamine (PE), phosphodiester (PDE) including glycerophosphocholine (GPC), phosphocreatine (PCr), nicotinamide adenine dinucleotide phosphate (NADPH), inorganic phosphate (Pi), γ-ATP and total phosphorus (TP). Saturation transfer technique was used to quantify hepatic ATP flux. Hepatic steatosis in 1 H-MRS highly correlated with histology (P<.001) showing higher values in NASH than NAFL (P<.001) without differences in saturated or unsaturated fatty acid indices. PE/TP ratio increased with advanced fibrosis (F3/4) (P=.002) whereas GPC/PME+PDE decreased (P=.05) compared to no/mild fibrosis (F0-2). γ-ATP/TP was lower in advanced fibrosis (P=.049), while PCr/TP increased (P=.01). NADPH/TP increased with higher grades of ballooning (P=.02). Pi-to-ATP exchange rate constant (P=.003) and ATP flux (P=.001) were lower in NASH than NAFL. Ultra-high-field MRS, especially saturation transfer technique uncovers changes in energy metabolism including dynamic ATP flux in inflammation and fibrosis in NASH. Non-invasive profiling by MRS appears feasible and may assist further mechanistic and therapeutic studies in NAFLD/NASH. © 2017 The Authors Liver International Published by John Wiley & Sons Ltd.
Lin, Jun; Du, Guanfeng; Zhang, Jian; Yi, Xiaofeng; Jiang, Chuandong; Lin, Tingting
2017-06-12
Magnetic resonance sounding (MRS) using the Earth's magnetic field is a noninvasive and on-site geophysical technique providing quantitative characteristics of aquifers in the subsurface. When the MRS technology is applied in a mine or tunnel for advance detecting the source of water that may cause disastrous accident, spatial constraints limit the size of coil sensor and thus lower the detection capability. In this paper, a coil sensor for detecting the weak MRS signal is designed and the signal to noise (SNR) for the coil sensor is analyzed and optimized. The coil sensor has a rigid structure and square size of 1 m for deploying in a narrow underground space and is cooled at a low temperature of 77 K for improving the SNR. A theoretical calculation and an experimental test in an electromagnetically shielded room (EMSR) show that the optimal design of coil sensor consists of an 80-turn coil and a low-current-noise preamplifier AD745. It has a field sensitivity of 0.17 fT / Hz in the EMSR at 77 K, which is superior to the low temperature Superconducting Quantum Interference Device (LT SQUID) that is the latest application in MRS and the cooled coil with a diameter of 9 cm when detecting the laboratory NMR signal in kHz range. In the field experiment above the Taipingchi Reservoir near Changchun in China, the cooled coil sensor (CCS) developed in this paper has successfully obtained a valid weak MRS signal in high noise environment. The field results showed that the quality of measured MRS signal at 77 K is significantly superior to that at 298 K and the SNR is improved up to three times. This property of CCS makes the MRS instrument more convenient and reliable in a constricted space underground engineering environment (e.g., a mine or a tunnel).
Lin, Jun; Du, Guanfeng; Zhang, Jian; Yi, Xiaofeng; Jiang, Chuandong; Lin, Tingting
2017-01-01
Magnetic resonance sounding (MRS) using the Earth’s magnetic field is a noninvasive and on-site geophysical technique providing quantitative characteristics of aquifers in the subsurface. When the MRS technology is applied in a mine or tunnel for advance detecting the source of water that may cause disastrous accident, spatial constraints limit the size of coil sensor and thus lower the detection capability. In this paper, a coil sensor for detecting the weak MRS signal is designed and the signal to noise (SNR) for the coil sensor is analyzed and optimized. The coil sensor has a rigid structure and square size of 1 m for deploying in a narrow underground space and is cooled at a low temperature of 77 K for improving the SNR. A theoretical calculation and an experimental test in an electromagnetically shielded room (EMSR) show that the optimal design of coil sensor consists of an 80-turn coil and a low-current-noise preamplifier AD745. It has a field sensitivity of 0.17 fT/Hz in the EMSR at 77 K, which is superior to the low temperature Superconducting Quantum Interference Device (LT SQUID) that is the latest application in MRS and the cooled coil with a diameter of 9 cm when detecting the laboratory NMR signal in kHz range. In the field experiment above the Taipingchi Reservoir near Changchun in China, the cooled coil sensor (CCS) developed in this paper has successfully obtained a valid weak MRS signal in high noise environment. The field results showed that the quality of measured MRS signal at 77 K is significantly superior to that at 298 K and the SNR is improved up to three times. This property of CCS makes the MRS instrument more convenient and reliable in a constricted space underground engineering environment (e.g., a mine or a tunnel). PMID:28604621
NASA Astrophysics Data System (ADS)
Abraham, J. D.; Kress, W. H.; Cannia, J. C.; Steele, G. V.; Smith, B. D.; Woodward, D.
2008-12-01
In 2007, the USGS in cooperation with the Central Platte Natural Resources District, central Nebraska, initiated a four year study to test the usefulness of magnetic resonance rounding (MRS) to gather information on aquifer characteristics. Magnetic resonance sounding is a ground surface applied tool which has the potential to measure hydraulic conductivity at depth using noninvasive means. This in turn will provide a low cost alternative to traditional aquifer tests. MRS also will allow for collection of large data sets of aquifer properties during short periods of time. The work is under way in Dawson County near Lexington, Nebraska to characterize the hydrogeology of the Quaternary-age alluvial and underlying Tertiary-age Ogallala Group aquifers that occur within the Platte River Valley. This county was selected because it lies in an area of Nebraska that has major groundwater- surface water management issues which have stimulated the development of regional and local groundwater models. Data used to evaluate the MRS during this study were derived from traditional constant discharge aquifer tests, borehole flow meter tests, lithologic descriptions, borehole geophysics, and time-domain electromagnetic soundings. This study presents methods and interpretation of MRS. The MRS-derived hydraulic conductivity data will be compared to hydraulic conductivity data from two separate constant discharge pumping tests of the alluvium and Ogallala Group aquifers at Site 72 The MRS-derived hydraulic conductivity data will also be compared to conductivity estimates based on data from a borehole flow meter test. This information can potentially be incorporated into groundwater models of the area to provide improved data sets of aquifer characteristics. The research will document an integrated MRS, surface geophysical, borehole geophysical, borehole flow meter and aquifer test approach in which the hydrostratigraphy of the Platte River alluvial aquifer and Ogallala aquifer can be described.
Casey, D. T.; Frenje, J. A.; Gatu Johnson, M.; ...
2013-04-18
The neutron spectrum produced by deuterium-tritium (DT) inertial confinement fusion implosions contains a wealth of information about implosion performance including the DT yield, iontemperature, and areal-density. The Magnetic Recoil Spectrometer (MRS) has been used at both the OMEGA laser facility and the National Ignition Facility (NIF) to measure the absolute neutron spectrum from 3 to 30 MeV at OMEGA and 3 to 36 MeV at the NIF. These measurements have been used to diagnose the performance of cryogenic target implosions to unprecedented accuracy. Interpretation of MRS data requires a detailed understanding of the MRS response and background. This paper describesmore » ab initio characterization of the system involving Monte Carlo simulations of the MRS response in addition to the commission experiments for in situ calibration of the systems on OMEGA and the NIF.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
Following the Department of Energy's announcement in April 1985 that three Tennessee sites were to be considered for the Monitored Retrievable Storage facility, Governor Lamar Alexander initiated a review of the proposal to be coordinated by his Safe Growth Team. Roane County and the City of Oak Ridge, the local governments sharing jurisdiction over DOE's primary and secondary sites, were invited to participate in the state's review of the MRS proposal. Many issues related to the proposed MRS are being considered by the Governor's Safe Growth Team. The primary objective of the Clinch River MRS Task Force has been tomore » determine whether the proposed Monitored Retrievable Storage facility should be accepted by the local governments, and if so, under what conditions. The Clinch River MRS Task Force is organized into an Executive Committee cochaired by the Roane County Executive and Mayor of Oak Ridge and three Study Groups focusing on environmental (including health and safety), socioeconomic, and transportation issues.« less
Casey, D T; Frenje, J A; Johnson, M Gatu; Séguin, F H; Li, C K; Petrasso, R D; Glebov, V Yu; Katz, J; Magoon, J; Meyerhofer, D D; Sangster, T C; Shoup, M; Ulreich, J; Ashabranner, R C; Bionta, R M; Carpenter, A C; Felker, B; Khater, H Y; LePape, S; MacKinnon, A; McKernan, M A; Moran, M; Rygg, J R; Yeoman, M F; Zacharias, R; Leeper, R J; Fletcher, K; Farrell, M; Jasion, D; Kilkenny, J; Paguio, R
2013-04-01
The neutron spectrum produced by deuterium-tritium (DT) inertial confinement fusion implosions contains a wealth of information about implosion performance including the DT yield, ion-temperature, and areal-density. The Magnetic Recoil Spectrometer (MRS) has been used at both the OMEGA laser facility and the National Ignition Facility (NIF) to measure the absolute neutron spectrum from 3 to 30 MeV at OMEGA and 3 to 36 MeV at the NIF. These measurements have been used to diagnose the performance of cryogenic target implosions to unprecedented accuracy. Interpretation of MRS data requires a detailed understanding of the MRS response and background. This paper describes ab initio characterization of the system involving Monte Carlo simulations of the MRS response in addition to the commission experiments for in situ calibration of the systems on OMEGA and the NIF.
Jeromel, Miran; Podobnik, Janez
2014-01-01
Background Most vertebral haemangioma are asymptomatic and discovered incidentally. Sometimes the symptomatic lesions present with radiological signs of aggressiveness and their appearance resemble other aggressive lesions (e.g. solitary plasmacytoma). Case report. We present a patient with large symptomatic aggressive haemangioma like lesion in 12th thoracic vertebra in which a magnetic resonance spectroscopy (MRS) was used to analyse fat content within the lesion. The lesion in affected vertebrae showed low fat content with 33% of fat fraction (%FF). The fat content in non-affected (1st lumbar) vertebra was as expected for patient’s age (68%). Based on MRS data, the lesion was characterized as an aggressive haemangioma. The diagnosis was confirmed with biopsy, performed during the treatment – percutaneous vertebroplasty. Conclusions The presented case shows that MRS can be used as an additional tool for evaluation of aggressiveness of vertebral haemangioma like lesions. PMID:24991203
Acute urinary retention due to benign inflammatory nervous diseases.
Sakakibara, Ryuji; Yamanishi, Tomonori; Uchiyama, Tomoyuki; Hattori, Takamichi
2006-08-01
Both neurologists and urologists might encounter patients with acute urinary retention due to benign inflammatory nervous diseases. Based on the mechanism of urinary retention, these disorders can be divided into two subgroups: disorders of the peripheral nervous system (e.g., sacral herpes) or the central nervous system (e.g., meningitis-retention syndrome [MRS]). Laboratory abnormalities include increased herpes virus titers in sacral herpes, and increased myelin basic protein in the cerebrospinal fluid (CSF) in some cases with MRS. Urodynamic abnormality in both conditions is detrusor areflexia; the putative mechanism of it is direct involvement of the pelvic nerves in sacral herpes; and acute spinal shock in MRS. There are few cases with CSF abnormality alone. Although these cases have a benign course, management of the acute urinary retention is necessary to avoid bladder injury due to overdistension. Clinical features of sacral herpes or MRS differ markedly from those of the original "Elsberg syndrome" cases.
NASA Astrophysics Data System (ADS)
Costabel, S.; Noell, U.; Ganz, C.
2012-04-01
Magnetic resonance sounding (MRS) is a non-invasive geophysical method for groundwater prospection that uses the principle of nuclear magnetic resonance (NMR) in the Earth's magnetic field. Its unique property distinct from other hydrogeophysical methods is the direct sensitivity to the amount of water, i.e. to the amount of 1H nuclei in the subsurface. Because MRS is normally used to investigate the water content of the saturated zone and to characterize aquifer structures, the standard application is optimized for 1D-measurements in depths from several to several tens of meters. However, our investigations show that MRS has also the potential to contribute substantially to the study of groundwater recharge if the sensitivity of the method for the unsaturated zone and for the transition to the saturated zone is increased by using a modified measurement setup and adjusted interpretation schemes. We conducted MRS test measurements with the focus on the very shallow subsurface in the range of some few decimeters down to the groundwater table in a depth of 3 m. The test site is located in the area Fuhrberger Feld about 30 km north-east of Hannover, Germany, which comprises an unconfined sandy aquifer of 20 to 30-m thickness. Previous studies have discovered the soil physical characteristics of the site with tension infiltrometer measurements and tracer irrigation experiments in the field, as well as with water retention measurements in the laboratory. In addition, several infiltration experiments with dye tracer were conducted and monitored with electrical resistivity tomography (ERT), tensiometers and TDR devices. For the MRS measurements at the testsite, a serious challenge was the intense electromagnetic noise consisting of large spiky radio signals and harmonic components, respectively. A special combination of new processing techniques was developed to isolate and interpret the NMR signals with amplitudes of approximately 5 to 14 nV. The standard inversion of the MRS data shows the ground water table at the correct depth and furthermore, increased residual water in the topsoil, which is verified by the water retention measurements in the lab. However, the amount of water at shallow depth down to 30 cm is difficult to quantify and to allocate exactly in depth due to the limited resolution properties of the method in this depth range. A new inversion scheme that parameterizes the capillary fringe using the van-Genuchten model was applied to the data. These results are in good agreement with the laboratory measurements. In order to develop MRS as a method for monitoring groundwater recharge processes, we combine hydraulic simulations and MRS forward modeling. Our numerical experiments suggest that the common MRS measurement scheme must be modified to enable faster repetitions, i.e., to resolve fast infiltration processes accordingly in time. For such modifications one must accept losses in the spatial resolution of the method. Compared to non-invasive ERT measurements with a 2D or 3D resolution in the decimeter range, the resolution properties of MRS are much worse. However, the direct sensitivity of the MRS method to the water content is an important benefit, whereas the quantification of water with ERT methods remains a serious problem. Therefore, we anticipate therefore that combining both methods could be the key for non-invasive monitoring of groundwater recharge in the future.
MRI and MRS on preserved samples as a tool in fish ecology.
Bock, Christian; Wermter, Felizitas C; Mintenbeck, Katja
2017-05-01
Magnetic Resonance Imaging (MRI) and Magnetic Resonance Spectroscopy (MRS) gain increasing attention and importance as a tool in marine ecology. So far, studies were largely limited to morphological studies, e.g. for the creation of digital libraries. Here, the utility of MRI and MRS for ecologists is tested and exemplified using formalin preserved samples of the Antarctic silverfish, Pleuragramma antarctica. As this species lacks a swim bladder, buoyancy is attained by the deposition of large amounts of lipids that are mainly stored in subcutaneous and intermuscular lipid sacs. In this study MRI and MRS are not only used to study internal morphology, but additionally to investigate functional morphology and to measure parameters of high ecological interest. The data are compared with literature data obtained by means of traditional ecological methods. The results from this study show that MR scans are not only an alternative to histological sections (as shown before), but even allow the visualization of particular features in delicate soft tissues, such as Pleuragramma's lipid sacs. 3D rendering techniques proved to be a useful tool to study organ volumes and lipid content, which usually requires laborious chemical lipid extraction and analysis. Moreover, the application of MRS even allows for an analysis of lipids and fatty acids within lipid sacs, which wouldn't be possible using destructive methods. MRI and MRS, in particular when used in combination, have the capacity to provide useful data on parameters of high ecological relevance and thus have proven to be a highly valuable addition, if not alternative, to the classical methods. Copyright © 2016 Elsevier Inc. All rights reserved.
Kang, Geraldine H.; Cruite, Irene; Shiehmorteza, Masoud; Wolfson, Tanya; Gamst, Anthony C.; Hamilton, Gavin; Bydder, Mark; Middleton, Michael S.; Sirlin, Claude B.
2016-01-01
Purpose To evaluate magnetic resonance imaging (MRI)-determined proton density fat fraction (PDFF) reproducibility across two MR scanner platforms and, using MR spectroscopy (MRS)-determined PDFF as reference standard, to confirm MRI-determined PDFF estimation accuracy. Materials and Methods This prospective, cross-sectional, crossover, observational pilot study was approved by an Institutional Review Board. Twenty-one subjects gave written informed consent and underwent liver MRI and MRS at both 1.5T (Siemens Symphony scanner) and 3T (GE Signa Excite HD scanner). MRI-determined PDFF was estimated using an axial 2D spoiled gradient-recalled echo sequence with low flip-angle to minimize T1 bias and six echo-times to permit correction of T2* and fat-water signal interference effects. MRS-determined PDFF was estimated using a stimulated-echo acquisition mode sequence with long repetition time to minimize T1 bias and five echo times to permit T2 correction. Interscanner reproducibility of MRI determined PDFF was assessed by correlation analysis; accuracy was assessed separately at each field strength by linear regression analysis using MRS-determined PDFF as reference standard. Results 1.5T and 3T MRI-determined PDFF estimates were highly correlated (r = 0.992). MRI-determined PDFF estimates were accurate at both 1.5T (regression slope/intercept = 0.958/−0.48) and 3T (slope/intercept = 1.020/0.925) against the MRS-determined PDFF reference. Conclusion MRI-determined PDFF estimation is reproducible and, using MRS-determined PDFF as reference standard, accurate across two MR scanner platforms at 1.5T and 3T. PMID:21769986
NASA Astrophysics Data System (ADS)
Costabel, Stephan; Siemon, Bernhard; Houben, Georg; Günther, Thomas
2017-01-01
A multi-method geophysical survey, including helicopter-borne electromagnetics (HEM), transient electromagnetics (TEM), and magnetic resonance sounding (MRS), was conducted to investigate a freshwater lens on the North Sea island of Langeoog, Germany. The HEM survey covers the entire island and gives an overview of the extent of three freshwater lenses that reach depths of up to 45 m. Ground-based TEM and MRS were conducted particularly on the managed western lens to verify the HEM results and to complement the lithological information from existing boreholes. The results of HEM and TEM are in good agreement. Salt- and freshwater-bearing sediments can, as expected, clearly be distinguished due to their individual resistivity ranges. In the resistivity data, a large transition zone between fresh- and saltwater with a thickness of up to 20 m is identified, the existence of which is verified by borehole logging and sampling. Regarding lithological characterisation of the subsurface, the MRS method provides more accurate and reliable results than HEM and TEM. Using a lithological index derived from MRS water content and relaxation time, thin aquitard structures as well as fine and coarse sand aquifers can be distinguished. Complementing the existing borehole data with the lithology information estimated from MRS, we generate a map showing the occurrence of aquitard structures, which significantly improves the hydrogeological model of the island. Moreover, we demonstrate that the estimates of groundwater conductivity in the sand aquifers from geophysical data are in agreement with the fluid conductivity measured in the boreholes.
Magnetic resonance spectroscopy metabolite profiles predict survival in paediatric brain tumours.
Wilson, Martin; Cummins, Carole L; Macpherson, Lesley; Sun, Yu; Natarajan, Kal; Grundy, Richard G; Arvanitis, Theodoros N; Kauppinen, Risto A; Peet, Andrew C
2013-01-01
Brain tumours cause the highest mortality and morbidity rate of all childhood tumour groups and new methods are required to improve clinical management. (1)H magnetic resonance spectroscopy (MRS) allows non-invasive concentration measurements of small molecules present in tumour tissue, providing clinically useful imaging biomarkers. The primary aim of this study was to investigate whether MRS detectable molecules can predict the survival of paediatric brain tumour patients. Short echo time (30ms) single voxel (1)H MRS was performed on children attending Birmingham Children's Hospital with a suspected brain tumour and 115 patients were included in the survival analysis. Patients were followed-up for a median period of 35 months and Cox-Regression was used to establish the prognostic value of individual MRS detectable molecules. A multivariate model of survival was also investigated to improve prognostic power. Lipids and scyllo-inositol predicted poor survival whilst glutamine and N-acetyl aspartate predicted improved survival (p<0.05). A multivariate model of survival based on three MRS biomarkers predicted survival with a similar accuracy to histologic grading (p<5e-5). A negative correlation between lipids and glutamine was found, suggesting a functional link between these molecules. MRS detectable biomolecules have been identified that predict survival of paediatric brain tumour patients across a range of tumour types. The evaluation of these biomarkers in large prospective studies of specific tumour types should be undertaken. The correlation between lipids and glutamine provides new insight into paediatric brain tumour metabolism that may present novel targets for therapy. Copyright © 2012 Elsevier Ltd. All rights reserved.
Kang, Geraldine H; Cruite, Irene; Shiehmorteza, Masoud; Wolfson, Tanya; Gamst, Anthony C; Hamilton, Gavin; Bydder, Mark; Middleton, Michael S; Sirlin, Claude B
2011-10-01
To evaluate magnetic resonance imaging (MRI)-determined proton density fat fraction (PDFF) reproducibility across two MR scanner platforms and, using MR spectroscopy (MRS)-determined PDFF as reference standard, to confirm MRI-determined PDFF estimation accuracy. This prospective, cross-sectional, crossover, observational pilot study was approved by an Institutional Review Board. Twenty-one subjects gave written informed consent and underwent liver MRI and MRS at both 1.5T (Siemens Symphony scanner) and 3T (GE Signa Excite HD scanner). MRI-determined PDFF was estimated using an axial 2D spoiled gradient-recalled echo sequence with low flip-angle to minimize T1 bias and six echo-times to permit correction of T2* and fat-water signal interference effects. MRS-determined PDFF was estimated using a stimulated-echo acquisition mode sequence with long repetition time to minimize T1 bias and five echo times to permit T2 correction. Interscanner reproducibility of MRI determined PDFF was assessed by correlation analysis; accuracy was assessed separately at each field strength by linear regression analysis using MRS-determined PDFF as reference standard. 1.5T and 3T MRI-determined PDFF estimates were highly correlated (r = 0.992). MRI-determined PDFF estimates were accurate at both 1.5T (regression slope/intercept = 0.958/-0.48) and 3T (slope/intercept = 1.020/0.925) against the MRS-determined PDFF reference. MRI-determined PDFF estimation is reproducible and, using MRS-determined PDFF as reference standard, accurate across two MR scanner platforms at 1.5T and 3T. Copyright © 2011 Wiley-Liss, Inc.
Zhang, Yu; Ng, I-Son; Yao, Chuanyi; Lu, Yinghua
2014-09-01
Lactobacillus rhamnosus is a well-known lactic acid bacterium (LAB), but a new ZY strain was isolated for the first time from commercial probiotic powder recently. Although many studies have focused on developing cost-effective media for the production of LAB, the de Man, Rogosa and Sharpe (MRS) medium is still the most common medium for bioprocesses. The aim of the current study is to decipher the composition of MRS based on a statistical approach, which will allow a higher biomass of Lactobacillus to be obtained. In Taguchi's approach, an L27 orthogonal array was adopted to evaluate the significance of 10 ingredients in MRS, in which the effects of the components were ranked according to their effect on biomass at OD600 as dextrose > MnSO4·H2O > beef extract > CH3COONa > MgSO4 > yeast extract > proteose peptone > K2HPO4 > ammonium citrate > Tween 80. Although the individual trace elements of ammonium citrate, K2HPO4, CH3COONa and MgSO4 in MRS had an insignificant influence on the biomass after statistical analysis, the total elimination of trace elements would predominantly affect the cell growth of Lactobacillus. Further characterization of the cell properties through attenuated total reflectance of Fourier transform infrared (ATR-FTIR) spectroscopy and protein identification via SDS-PAGE coupled with tandem mass spectrometry implied that dextrose as major carbon source in MRS played the most crucial role for L. rhamnosus production. Copyright © 2014 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.
Detection of cerebral NAD+ in humans at 7T.
de Graaf, Robin A; De Feyter, Henk M; Brown, Peter B; Nixon, Terence W; Rothman, Douglas L; Behar, Kevin L
2017-09-01
To develop 1 H-based MR detection of nicotinamide adenine dinucleotide (NAD + ) in the human brain at 7T and validate the 1 H results with NAD + detection based on 31 P-MRS. 1 H-MR detection of NAD + was achieved with a one-dimensional double-spin-echo method on a slice parallel to the surface coil transceiver. Perturbation of the water resonance was avoided through the use of frequency-selective excitation. 31 P-MR detection of NAD + was performed with an unlocalized pulse-acquire sequence. Both 1 H- and 31 P-MRS allowed the detection of NAD + signals on every subject in 16 min. Spectral fitting provided an NAD + concentration of 107 ± 28 μM for 1 H-MRS and 367 ± 78 μM and 312 ± 65 μM for 31 P-MRS when uridine diphosphate glucose (UDPG) was excluded and included, respectively, as an overlapping signal. NAD + detection by 1 H-MRS is a simple method that comes at the price of reduced NMR visibility. NAD + detection by 31 P-MRS has near-complete NMR visibility, but it is complicated by spectral overlap with NADH and UDPG. Overall, the 1 H- and 31 P-MR methods both provide exciting opportunities to study NAD + metabolism on human brain in vivo. © 2016 International Society for Magnetic Resonance in Medicine. Magn Reson Med 78:828-835, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.
Photocopy of photograph (from Mrs. Martin, grandniece of John French, ...
Photocopy of photograph (from Mrs. Martin, grandniece of John French, Clinton, Missouri) Circa 1900, photographer unknown JOHN AND ALMIRA FRENCH IN FRONT OF WEST AND SOUTH FACADES - John French Farm, South Grand River, Deepwater, Henry County, MO
ERIC Educational Resources Information Center
Ross, Lynne
1970-01-01
Excerpts from a talk by Mrs. Ross at the 23rd annual convention of the American School Food Service Association in Detroit, August 5, 1969. A book on work simplification by Mrs. Ross will be available in June from the Iowa State University Press, Ames, Iowa. (Editor)
10. Photocopy of an engraving of a stained glass window ...
10. Photocopy of an engraving of a stained glass window design by Johann Friedrich Overbeck (1789-1869) on which two of the chancel windows in the Church of the Holy Cross are thought to have been based. This copy is of a photocopy obtained from the Treasury of Notre Dame de Paris, Paris, France, by the late Mrs. Walter C. White of Stateburg, South Carolina. Mrs. White's photocopy is in the possession of Mrs. Richard K. Anderson of the Borough House at Stateburg. - Church of the Holy Cross, State Route 261, Stateburg, Sumter County, SC
Wijtenburg, S. Andrea; Yang, Shaolin; Fischer, Bernard A.; Rowland, Laura M.
2015-01-01
In vivo measurement of neurotransmitters and modulators is now feasible with advanced proton magnetic resonance spectroscopy (1H-MRS) techniques. This review provides a basic tutorial of MRS, describes the methods available to measure brain glutamate, glutamine, γ-aminobutyric acid, glutathione, N-acetylaspartylglutamate, glycine, and serine at magnetic field strengths of 3Tesla or higher, and summarizes the neurochemical findings in schizophrenia. Overall, 1H-MRS holds great promise for producing biomarkers that can serve as treatment targets, prediction of disease onset, or illness exacerbation in schizophrenia and other brain diseases. PMID:25614132
Rackayova, Veronika; Cudalbu, Cristina; Pouwels, Petra J W; Braissant, Olivier
2017-07-15
Creatine (Cr) is an important organic compound acting as intracellular high-energy phosphate shuttle and in energy storage. While located in most cells where it plays its main roles in energy metabolism and cytoprotection, Cr is highly concentrated in muscle and brain tissues, in which Cr also appears to act in osmoregulation and neurotransmission. This review discusses the basis of Cr metabolism, synthesis and transport within brain cells. The importance of Cr in brain function and the consequences of its impaired metabolism in primary and secondary Cr deficiencies are also discussed. Cr and phosphocreatine (PCr) in living systems can be well characterized using in vivo magnetic resonance spectroscopy (MRS). This review describes how 1 H MRS allows the measurement of Cr and PCr, and how 31 P MRS makes it possible to estimate the creatine kinase (CK) rate constant and so detect dynamic changes in the Cr/PCr/CK system. Absolute quantification by MRS using creatine as internal reference is also debated. The use of in vivo MRS to study brain Cr in a non-invasive way is presented, as well as its use in clinical and preclinical studies, including diagnosis and treatment follow-up in patients. Copyright © 2016 Elsevier Inc. All rights reserved.
Magnetic resonance imaging spectroscopy in pediatric atypical teratoid rhabdoid tumors of the brain.
Bruggers, Carol S; Moore, Kevin
2014-08-01
Pediatric central nervous system (CNS) atypical teratoid rhabdoid tumors (ATRT) are highly malignant tumors characterized by SMARCB1 gene abnormalities. Despite chemoradiation responsiveness, most children die of disease. No imaging findings distinguish ATRT from other malignant brain tumors. This study sought to describe magnetic resonance spectroscopy (MRS) of childhood CNS ATRT and identify metabolite patterns for diagnosis and disease status monitoring. Data from 7 children diagnosed with CNS ATRT from 2007 to 2010, whose imaging included MRS, were retrospectively reviewed. Age at diagnosis ranged from 2.5 to 54 months. Tumors were large with calcium and cysts and avid gadolinium enhancement. All were isointense on T1-weighted imaging and mildly hyperintense on T2-weighted imaging. Short-TE MRS showed prominent lactate+lipid and choline, minimal N-acetyl acetate (NAA), and rarely minimal myoinositol and low creatine peaks. Long TE showed prominent choline, minimal NAA, and rarely low lactate peaks. The combination of prominent choline and lactate+lipids peaks, and generally absent NAA and myoinositol peaks by MRS in this panel of ATRT expands existing information and provides a potentially distinct metabolite profile from other malignant pediatric brain tumors, including medulloblastoma. Prospective, comparative quantitative MRS of ATRT with other pediatric CNS tumors is warranted.
Mangia, Silvia; Giove, Federico; Tkáč, Ivan; Logothetis, Nikos K.; Henry, Pierre-Gilles; Olman, Cheryl A.; Maraviglia, Bruno; Di Salle, Francesco; Uğurbil, Kâmil
2009-01-01
Unraveling the energy metabolism and the hemodynamic outcomes of excitatory and inhibitory neuronal activity is critical not only for our basic understanding of overall brain function, but also for the understanding of many brain disorders. Methodologies of magnetic resonance spectroscopy (MRS) and magnetic resonance imaging (MRI) are powerful tools for the non-invasive investigation of brain metabolism and physiology. However, the temporal and spatial resolution of in vivo MRS and MRI is not suitable to provide direct evidence for hypotheses that involve metabolic compartmentalization between different cell types, or to untangle the complex neuronal micro-circuitry which results in changes of electrical activity. This review aims at describing how the current models of brain metabolism, mainly built on the basis of in vitro evidence, relate to experimental findings recently obtained in vivo by 1H MRS, 13C MRS and MRI. The hypotheses related to the role of different metabolic substrates, the metabolic neuron-glia interactions, along with the available theoretical predictions of the energy budget of neurotransmission, will be discussed. In addition, the cellular and network mechanisms that characterize different types of increased and suppressed neuronal activity will be considered within the sensitivity-constraints of MRS and MRI. PMID:19002199
The reproducibility of 31-phosphorus MRS measures of muscle energetics at 3 Tesla in trained men.
Edwards, Lindsay M; Tyler, Damian J; Kemp, Graham J; Dwyer, Renee M; Johnson, Andrew; Holloway, Cameron J; Nevill, Alan M; Clarke, Kieran
2012-01-01
Magnetic resonance spectroscopy (MRS) provides an exceptional opportunity for the study of in vivo metabolism. MRS is widely used to measure phosphorus metabolites in trained muscle, although there are no published data regarding its reproducibility in this specialized cohort. Thus, the aim of this study was to assess the reproducibility of (31)P-MRS in trained skeletal muscle. We recruited fifteen trained men (VO(2)peak = 4.7±0.8 L min(-1)/58±8 mL kg(-1) min(-1)) and performed duplicate MR experiments during plantar flexion exercise, three weeks apart. Measures of resting phosphorus metabolites were reproducible, with 1.7 mM the smallest detectable difference in phosphocreatine (PCr). Measures of metabolites during exercise were less reliable: exercising PCr had a coefficient of variation (CV) of 27% during exercise, compared with 8% at rest. Estimates of mitochondrial function were variable, but experimentally useful. The CV of PCr(1/2t) was 40%, yet much of this variance was inter-subject such that differences of <20% were detectable with n = 15, given a significance threshold of p<0.05. 31-phosphorus MRS provides reproducible and experimentally useful measures of phosphorus metabolites and mitochondrial function in trained human skeletal muscle.
In VivoQuantitation of Cerebral Metabolite Concentrations Using Natural Abundance 13C MRS at 1.5 T
NASA Astrophysics Data System (ADS)
Blüml, Stefan
1999-02-01
A method for the quantitation of cerebral metabolites on a clinical MR scanner by natural abundance13C MRSin vivois described. Proton-decoupled spectra were acquired with a power deposition within FDA guidelines using a novel coil design.myo-Inositol, quantified by a separate proton MRS, and readily detectable in13C MRS, was used as an internal reference. Normal concentrations, measured in four control subjects, age 7 months to 12 years, were glutamate 9.9 ± 0.7, glutamine 5.6 ± 1.0, and NAA 8.8 ± 2.8 mmol/kg. In a patient diagnosed with Canavan disease, examined four times, glutamate was reduced to 46% of normal, 4.6 ± 0.5 mmol/kg. NAA was increased by 50% to 13.2 ± 1.6 mmol/kg in13C MRS, consistent with the 41% increase to 12.3 ± 1.1 from control 8.7 ± 1.1 mmol/kg assayed by1H MRS. Limited concentration of glutamate may impact on glutamatergic neurons and excitatory neurotransmission in Canavan disease. Quantitation of cerebral glutamate in human brain may have clinical value in human neuropathologies in which glutamate is believed to play a central role.
The good, the bad and the ugly of marine reserves for fishery yields.
De Leo, Giulio A; Micheli, Fiorenza
2015-11-05
Marine reserves (MRs) are used worldwide as a means of conserving biodiversity and protecting depleted populations. Despite major investments in MRs, their environmental and social benefits have proven difficult to demonstrate and are still debated. Clear expectations of the possible outcomes of MR establishment are needed to guide and strengthen empirical assessments. Previous models show that reserve establishment in overcapitalized, quota-based fisheries can reduce both catch and population abundance, thereby negating fisheries and even conservation benefits. By using a stage-structured, spatially explicit stochastic model, we show that catches under quota-based fisheries that include a network of MRs can exceed maximum sustainable yield (MSY) under conventional quota management if reserves provide protection to old, large spawners that disproportionally contribute to recruitment outside the reserves. Modelling results predict that the net fishery benefit of MRs is lost when gains in fecundity of old, large individuals are small, is highest in the case of sedentary adults with high larval dispersal, and decreases with adult mobility. We also show that environmental variability may mask fishery benefits of reserve implementation and that MRs may buffer against collapse when sustainable catch quotas are exceeded owing to stock overestimation or systematic overfishing. © 2015 The Author(s).
1988-01-01
otten us f or O ,,,¢0 pirprt-. CMerT s, lnrltdln the new microfine products, and acrvlites ,I1 W- -M -mrs a W- Wv - are the materials most suitable...availability - Ground freezing require a relatively Ismall amount of materials, principal!y steel (or aluminum), pipe, rubber hose and plastic tubing ...external confining pressure, or stresses imposed during installation. Plastic pipe should be avoided, except for inner tubing or surface piping, because
Supplemental report of the Attorney General to the Safe Growth Cabinet Council
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wurz, R.T.
In February of 1986, the Department of Energy (DOE) will present to Congress a proposal to construct a Monitored Retrievable Storage facility (MRS) in Tennessee. This report is a listing of the comments received regarding the MRS plan.
Supplemental report of the Attorney General to the Safe Growth Cabinet Council
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wurz, R.T.
1986-01-07
In February of 1986, the Department of Energy (DOE) will present to Congress a proposal to construct a Monitored Retrievable Storage facility (MRS) in Tennessee. This report is a listing of the comments received regarding the MRS plan.
1990-04-06
Andrasfalvy 2 Pecs Zoltan Trombitas Sandor Szeles Mrs. Kaposi, Dr. -Andras Pap Sandor Gyulai; Maria Dunai Jozsef Kuller; Dr. Istvan Marton 3 Pecs Dr. Andrea ...Csizmadia Mrs. Szabo, Erzsebet Kovacs 5 Varpalota Peter Patonai Laszlo Czifra Janos Csovari Janos Kovacs Ferenc Schmidt Tibor Fakasz 6 Veszprem -Ferenc
NASA Astrophysics Data System (ADS)
Craciun, Valentin; Sánchez, Florencio
2016-09-01
The present issue contains a collection of representative papers presented in the Symposium L, "Towards Oxide-Based Electronics: growth and applications of oxide thin films and heterostructures", organized during the E-MRS Fall Meeting, 15-18 September 2015 in Warsaw, Poland. The Symposium L was organised and sponsored by the COST Action MP1308 "Towards oxide-based electronics" (TO-BE), a four-year EU project that started in June 2014. Over 100 participants from different countries all over the world presented new results on oxide thin films epitaxial growth, on emergent functionalities at oxide interfaces, and on applications of oxides in the fields on nanoelectronics, energy, sensing and actuation.
Big GABA: Edited MR spectroscopy at 24 research sites.
Mikkelsen, Mark; Barker, Peter B; Bhattacharyya, Pallab K; Brix, Maiken K; Buur, Pieter F; Cecil, Kim M; Chan, Kimberly L; Chen, David Y-T; Craven, Alexander R; Cuypers, Koen; Dacko, Michael; Duncan, Niall W; Dydak, Ulrike; Edmondson, David A; Ende, Gabriele; Ersland, Lars; Gao, Fei; Greenhouse, Ian; Harris, Ashley D; He, Naying; Heba, Stefanie; Hoggard, Nigel; Hsu, Tun-Wei; Jansen, Jacobus F A; Kangarlu, Alayar; Lange, Thomas; Lebel, R Marc; Li, Yan; Lin, Chien-Yuan E; Liou, Jy-Kang; Lirng, Jiing-Feng; Liu, Feng; Ma, Ruoyun; Maes, Celine; Moreno-Ortega, Marta; Murray, Scott O; Noah, Sean; Noeske, Ralph; Noseworthy, Michael D; Oeltzschner, Georg; Prisciandaro, James J; Puts, Nicolaas A J; Roberts, Timothy P L; Sack, Markus; Sailasuta, Napapon; Saleh, Muhammad G; Schallmo, Michael-Paul; Simard, Nicholas; Swinnen, Stephan P; Tegenthoff, Martin; Truong, Peter; Wang, Guangbin; Wilkinson, Iain D; Wittsack, Hans-Jörg; Xu, Hongmin; Yan, Fuhua; Zhang, Chencheng; Zipunnikov, Vadim; Zöllner, Helge J; Edden, Richard A E
2017-10-01
Magnetic resonance spectroscopy (MRS) is the only biomedical imaging method that can noninvasively detect endogenous signals from the neurotransmitter γ-aminobutyric acid (GABA) in the human brain. Its increasing popularity has been aided by improvements in scanner hardware and acquisition methodology, as well as by broader access to pulse sequences that can selectively detect GABA, in particular J-difference spectral editing sequences. Nevertheless, implementations of GABA-edited MRS remain diverse across research sites, making comparisons between studies challenging. This large-scale multi-vendor, multi-site study seeks to better understand the factors that impact measurement outcomes of GABA-edited MRS. An international consortium of 24 research sites was formed. Data from 272 healthy adults were acquired on scanners from the three major MRI vendors and analyzed using the Gannet processing pipeline. MRS data were acquired in the medial parietal lobe with standard GABA+ and macromolecule- (MM-) suppressed GABA editing. The coefficient of variation across the entire cohort was 12% for GABA+ measurements and 28% for MM-suppressed GABA measurements. A multilevel analysis revealed that most of the variance (72%) in the GABA+ data was accounted for by differences between participants within-site, while site-level differences accounted for comparatively more variance (20%) than vendor-level differences (8%). For MM-suppressed GABA data, the variance was distributed equally between site- (50%) and participant-level (50%) differences. The findings show that GABA+ measurements exhibit strong agreement when implemented with a standard protocol. There is, however, increased variability for MM-suppressed GABA measurements that is attributed in part to differences in site-to-site data acquisition. This study's protocol establishes a framework for future methodological standardization of GABA-edited MRS, while the results provide valuable benchmarks for the MRS community. Copyright © 2017 Elsevier Inc. All rights reserved.
How do Medical Radiation Science educators keep up with the [clinical] Joneses?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giles, Eileen
Medical radiation science (MRS) disciplines include medical imaging, radiation therapy and nuclear medicine. These allied health fields are technology driven and evolving rapidly with regard to imaging and treatment techniques within the clinical environment. This research aims to identify the activities academics are currently participating in to maintain clinical currency and offer strategies to support academics to connect with an ever-changing clinical environment. A cross-sectional designed survey was sampled across the nine Australian universities where MRS programmes are offered. The survey targeted academic teaching staff that were working in MRS programmes at the time of distribution (n ≈ 90). Enablersmore » and barriers to maintaining clinical currency as well as support to participate in continuing professional development were rated by the respondents. Descriptive statistics were used to analyse quantitative data, and free-text comment responses were collated and themed. There were 38 responses to the survey (42%) and all three disciplines were represented. Responses highlighted activities valued by academics as contributing to their knowledge of current practice and as resources to inform their teaching. Positive elements included participating in clinical work and research, attending clinical sites and training days and attending scientific meetings. Common barriers identified by academics in this area were time constraints, workload allocation and employer/financial support. This research has identified that Australian MRS academics participate in a broad range of activities to inform their teaching and maintain knowledge of contemporary clinical practice. A connection with the clinical world is valued highly by academics, however, access and support to maintain that link is often a difficulty and as a result for MRS teaching staff keeping up with the clinical [MRS] Joneses is often a challenge.« less
Quantitative Chemical Shift-Encoded MRI Is an Accurate Method to Quantify Hepatic Steatosis
Kühn, Jens-Peter; Hernando, Diego; Mensel, Birger; Krüger, Paul C.; Ittermann, Till; Mayerle, Julia; Hosten, Norbert; Reeder, Scott B.
2014-01-01
Purpose To compare the accuracy of liver fat quantification using a three-echo chemical shift-encoded magnetic resonance imaging (MRI) technique without and with correction for confounders with spectroscopy (MRS) as the reference standard. Materials and Methods Fifty patients (23 women, mean age 56.6 ± 13.2 years) with fatty liver disease were enrolled. Patients underwent T2-corrected single-voxel MRS and a three-echo chemical shift-encoded gradient echo (GRE) sequence at 3.0T. MRI fat fraction (FF) was calculated without and with T2* and T1 correction and multispectral modeling of fat and compared with MRS-FF using linear regression. Results The spectroscopic range of liver fat was 0.11%–38.7%. Excellent correlation between MRS-FF and MRI-FF was observed when using T2* correction (R2=0.96). With use of T2* correction alone, the slope was significantly different from 1 (1.16 ± 0.03, P < 0.001) and the intercept was different from 0 (1.14% ± 0.50%, P < 0.023). This slope was significantly different than 1.0 when no T1 correction was used (P=0.001). When T2*, T1, and spectral complexity of fat were addressed, the results showed equivalence between fat quantification using MRI and MRS (slope: 1.02 ± 0.03, P=0.528; intercept: 0.26% ± 0.46%, P=0.572). Conclusion Complex three-echo chemical shift-encoded MRI is equivalent to MRS for quantifying liver fat, but only with correction for T2* decay and T1 recovery and use of spectral modeling of fat. This is necessary because T2* decay, T1 recovery, and multispectral complexity of fat are processes which may otherwise bias the measurements. PMID:24123655
Quantitative chemical shift-encoded MRI is an accurate method to quantify hepatic steatosis.
Kühn, Jens-Peter; Hernando, Diego; Mensel, Birger; Krüger, Paul C; Ittermann, Till; Mayerle, Julia; Hosten, Norbert; Reeder, Scott B
2014-06-01
To compare the accuracy of liver fat quantification using a three-echo chemical shift-encoded magnetic resonance imaging (MRI) technique without and with correction for confounders with spectroscopy (MRS) as the reference standard. Fifty patients (23 women, mean age 56.6 ± 13.2 years) with fatty liver disease were enrolled. Patients underwent T2-corrected single-voxel MRS and a three-echo chemical shift-encoded gradient echo (GRE) sequence at 3.0T. MRI fat fraction (FF) was calculated without and with T2* and T1 correction and multispectral modeling of fat and compared with MRS-FF using linear regression. The spectroscopic range of liver fat was 0.11%-38.7%. Excellent correlation between MRS-FF and MRI-FF was observed when using T2* correction (R(2) = 0.96). With use of T2* correction alone, the slope was significantly different from 1 (1.16 ± 0.03, P < 0.001) and the intercept was different from 0 (1.14% ± 0.50%, P < 0.023). This slope was significantly different than 1.0 when no T1 correction was used (P = 0.001). When T2*, T1, and spectral complexity of fat were addressed, the results showed equivalence between fat quantification using MRI and MRS (slope: 1.02 ± 0.03, P = 0.528; intercept: 0.26% ± 0.46%, P = 0.572). Complex three-echo chemical shift-encoded MRI is equivalent to MRS for quantifying liver fat, but only with correction for T2* decay and T1 recovery and use of spectral modeling of fat. This is necessary because T2* decay, T1 recovery, and multispectral complexity of fat are processes which may otherwise bias the measurements. Copyright © 2013 Wiley Periodicals, Inc.
Poloni, Guy; Bastianello, S; Vultaggio, Angela; Pozzi, S; Maccabelli, Gloria; Germani, Giancarlo; Chiarati, Patrizia; Pichiecchio, Anna
2008-01-01
The field of application of magnetic resonance spectroscopy (MRS) in biomedical research is expanding all the time and providing opportunities to investigate tissue metabolism and function. The data derived can be integrated with the information on tissue structure gained from conventional and non-conventional magnetic resonance imaging (MRI) techniques. Clinical MRS is also strongly expected to play an important role as a diagnostic tool. Essential for the future success of MRS as a clinical and research tool in biomedical sciences, both in vivo and in vitro, is the development of an accurate, biochemically relevant and physically consistent and reliable data analysis standard. Stable and well established analysis algorithms, in both the time and the frequency domain, are already available, as is free commercial software for implementing them. In this study, we propose an automatic algorithm that takes into account anatomical localisation, relative concentrations of white matter, grey matter, cerebrospinal fluid and signal abnormalities and inter-scan patient movement. The endpoint is the collection of a series of covariates that could be implemented in a multivariate analysis of covariance (MANCOVA) of the MRS data, as a tool for dealing with differences that may be ascribed to the anatomical variability of the subjects, to inaccuracies in the localisation of the voxel or slab, or to movement, rather than to the pathology under investigation. The aim was to develop an analysis procedure that can be consistently and reliably applied in the follow up of brain tumour. In this study, we demonstrate that the inclusion of such variables in the data analysis of quantitative MRS is fundamentally important (especially in view of the reduced accuracy typical of MRS measures compared to other MRI techniques), reducing the occurrence of false positives.
Wu, R H; Lin, R; Li, H; Xiao, Z W; Rao, H B; Luo, W H; Guo, G; Huang, K; Zhang, X G; Lang, Z J
2005-01-01
The metabolite ratios had been employed in the field of MR spectroscopy (MRS) for a long period. The main drawback of metabolite ratio is that ratio results are not comparable with absolute metabolite concentration in vivo. The purpose of this study was to examine the accuracy of noninvasive quantification of brain N-acetylaspartate (NAA) concentrations using previously reported MR external standard method. Eight swine were scanned on a GE 1.5 T scanner with a standard head coil. The external standard method was utilized with a sphere filled with NAA, GABA, glutamine, glutamate, creatine, choline chloride, and myo-inositol. The position resolved spectroscopy (PRESS) sequence was used with TE=135 msec, TR=1500 msec, and 128 scan averages. The analysis of MRS was done with SAGE/IDL program. In vivo NAA concentration was obtained using the equation S=N * e(-TE/T2) * [1-e(-TR/T1). In vitro NAA concentration was measured by high performance liquid chromatography (HPLC). In the MRS group, the mean concentration of NAA was 10.03 plusmn 0.74 mmol/kg. In the HPLC group, the mean concentration of NAA was 9.22 plusmn 0.55 mmol/kg. There was no significant difference between the two groups (p = 0.46). However, slightly higher value was observed in the MRS group (7/8 swine), compared with HPLC group. The range of differences was between 0.02~2.05 mmol/kg. MRS external reference method could be more accurate than internal reference method. 1H MRS does not distinguish between N-acetyl resonance frequencies and other N-acetylated amino acids.
Functional outcome of microsurgical clipping compared to endovascular coiling.
Premananda, R M; Ramesh, N; Hillol, K P
2012-12-01
Endovascular coiling has been used increasingly as an alternative to neurosurgical clipping for treating subarachnoid hemorrhage secondary to aneurysm rupture. In a retrospective cohort review on the treatment methods of aneurysm rupture in Hospital Kuala Lumpur over the period of five years (2005-2009) a total of 268 patients were treated. These patients were broadly categorized into two groups based on their treatment mode for ruptured aneurysms. Statistical analysis was determined using Chi- Square tests to study these associations. In our study, 67.5% of patients presented with Good World Federation of Neurosurgical Societies (WFNS) grade (WFNS1-2) while 32.5% patients presented with Poor WFNS prior to intervention. In our outcome, it was noted that 60.4% had good functional outcome (mRS grade 0-2) as compared to 39.6% patients who had poor mRS(modified rankin scale) outcome (mRS 3-6). In the good WFNS group, 76% of patients in clipping group had a good mRS outcome while, 86.5% patients in coiling group had good mRS outcome (p=0.114). In poor WFNS presentation, it was noted that in 77.3% patients in clipping group, had poor mRS outcome. Similarly with poor WFNS presentation, 83.3% of patient in coiling group had poor outcome. (p=1.00). Hence when we control the WFNS group, there was no significant association between treatment group (clipping and coiling) and mRS outcome at 6 months. The outcome of patient is determined by initial clinical presentation (WFNS grade) and influenced by requirement of Extraventricular drain (EVD) in presence of hydrocephalus, CSF infection and pneumonia. Therefore the decision regarding treatment option needs to be individualized based on the presentation of the patient.
Menopausal symptoms and the menopausal rating scale among midlife chinese women in Macau, China.
Chou, Mei Fong; Wun, Yuk Tsan; Pang, Sai Meng
2014-01-01
Studies on menopause-related quality of life (QoL), especially using the Menopausal Rating Scale (MRS), in Asian women are scarce. This study surveyed menopausal symptoms in a convenience sample of 442 Chinese women aged 40-60 years who attended the Well-Women Clinic, Macau, China, in a public health center. The questionnaire included sociodemographic data, the MRS, and a novel question on which area of QoL was affected. The average age of the participants was 49.2±5.08 years, and 98.9% of them reported experiencing menopausal symptoms. The four most prevalent menopausal symptoms were physical and mental exhaustion (90.3%), joint and muscle discomfort (88.5%), irritability (78.1%), and sleep problems (77.1%). The average MRS score was 14.2±8.80. A severe MRS score (≥17) was found in 35.5% of participants. Severe scores in the psychological, somatic, and urogenital MRS subscales were found in 17.9%, 42.8%, and 34.8%, of women, respectively. Menopausal symptoms affected QoL in 57.2% of women: daily life in 36.7%, work in 29.2%, sexual life in 17.0%, and relationship with husband in 13.8%. Daily life was significantly affected by hot flushes and joint/muscular discomfort; work was reportedly affected by irritability and exhaustion; sexual life was reported to be affected by hot flushes, sexual problems, and vaginal dryness, and relationship with husband was affected by sexual problems. We concluded that menopausal symptoms were highly prevalent among midlife Chinese women and often affected their QoL. The MRS, however, did not have a high sensitivity in detecting impaired QoL.
Early Alzheimer's Disease Neuropathology Detected by Proton MR Spectroscopy
Murray, Melissa E.; Przybelski, Scott A.; Lesnick, Timothy G.; Liesinger, Amanda M.; Spychalla, Anthony; Zhang, Bing; Gunter, Jeffrey L.; Parisi, Joseph E.; Boeve, Bradley F.; Knopman, David S.; Petersen, Ronald C.; Jack, Clifford R.; Dickson, Dennis W.
2014-01-01
Proton magnetic resonance spectroscopy (1H-MRS) is sensitive to early neurodegenerative processes associated with Alzheimer's disease (AD). Although 1H-MRS metabolite ratios of N-acetyl aspartate (NAA)/creatine (Cr), NAA/myoinositol (mI), and mI/Cr measured in the posterior cingulate gyrus reveal evidence of disease progression in AD, pathologic underpinnings of the 1H-MRS metabolite changes in AD are unknown. Pathologically diagnosed human cases ranging from no likelihood to high likelihood AD (n = 41, 16 females and 25 males) who underwent antemortem 1H-MRS of the posterior cingulate gyrus at 3 tesla were included in this study. Immunohistochemical evaluation was performed on the posterior cingulate gyrus using antibodies to synaptic vesicles, hyperphosphorylated tau (pTau), neurofibrillary tangle conformational-epitope (cNFT), amyloid-β, astrocytes, and microglia. The slides were digitally analyzed using Aperio software, which allows neuropathologic quantification in the posterior cingulate gray matter. MRS and pathology associations were adjusted for time from scan to death. Significant associations across AD and control subjects were found between reduced synaptic immunoreactivity and both NAA/Cr and NAA/mI in the posterior cingulate gyrus. Higher pTau burden was associated with lower NAA/Cr and NAA/mI. Higher amyloid-β burden was associated with elevated mI/Cr and lower NAA/mI ratios, but not with NAA/Cr. 1H-MRS metabolite levels reveal early neurodegenerative changes associated with AD pathology. Our findings support the hypothesis that a decrease in NAA/Cr is associated with loss of synapses and early pTau pathology, but not with amyloid-β or later accumulation of cNFT pathology in the posterior cingulate gyrus. In addition, elevation of mI/Cr is associated with the occurrence of amyloid-β plaques in AD. PMID:25471565
Dieckmeyer, Michael; Ruschke, Stefan; Eggers, Holger; Kooijman, Hendrik; Rummeny, Ernst J; Kirschke, Jan S; Baum, Thomas; Karampinos, Dimitrios C
2017-10-01
To remove the confounding effect of unsuppressed fat on the imaging-based apparent diffusion coefficient (ADC) of the vertebral bone marrow water component when using spectrally selective fat suppression and to compare and validate the proposed quantification strategy against diffusion-weighted magnetic resonance spectroscopy (DW-MRS). Twelve subjects underwent diffusion-weighted imaging (DWI) and DW-MRS of the vertebral bone marrow. A theoretical model was developed to take into account and correct the effects of residual fat on ADC, incorporating additional measurements for proton density fat fraction (PDFF) and water T 2 (T 2w ). Uncorrected and corrected DWI-based ADC was compared with DW-MRS-based ADC using the Bland-Altman method. There was a systematic bias equal to 0.118 ± 0.116 × 10 -3 mm 2 /s between DWI and DW-MRS when no correction was performed. Taking into account measured PDFF and constant T 2w reduced the bias to 0.006 ± 0.128 × 10 -3 mm 2 /s. Using the proposed approach with both individually measured PDFF and T 2w reduced both the bias and the limits of agreement between DWI and DW-MRS (0.018 ± 0.065 × 10 -3 mm 2 /s). By taking into account the presence of residual fat in a modified signal model that incorporates additional individual measurements of PDFF and T 2w , good agreement of imaging-based ADC with MRS-based ADC can be achieved in vertebral bone marrow. Magn Reson Med 78:1432-1441, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.
Annalisa Gnoleba, MSA | Division of Cancer Prevention
Mrs. Annalisa Gnoleba is the Public Health Analyst for the Cancer Prevention Fellowship Program, Division of Cancer Prevention, National Cancer Institute. In this position, Mrs. Gnoleba serves as the analyst for developing and formulating short and long range public health program goals, objectives and policies. |
40 CFR 86.1360-2007 - Supplemental emission test; test cycle and procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) * (MZ-MRS) / (MTU-MRS) ETU = ET + (EU-ET) * (nZ-nRT) / (nSU-nRT) ERS = ER + (ES-ER) * (nZ-nRT) / (nSU-n..., ET, EU = for each regulated pollutant, brake specific gaseous emissions of the enveloping modes...
Lanza, Ian R.; Bhagra, Sumit; Nair, K. Sreekumaran; Port, John D.
2011-01-01
Purpose To cross-validate skeletal muscle oxidative capacity measured by 31P-MRS with in vitro measurements of oxidative capacityin mitochondria isolated from muscle biopsies of the same muscle group in 18 healthy adults. Materials and Methods Oxidative capacity in vivo was determined from PCr recovery kinetics following a 30s maximal isometric knee extension. State 3 respiration was measured in isolated mitochondria using high-resolution respirometry. A second cohort of 10 individuals underwent two 31P-MRS testing sessions to assess the test-retest reproducibility of the method. Results Overall, the in vivo and in vitro methods were well-correlated (r = 0.66 –0.72) and showed good agreement by Bland Altman plots. Excellent reproducibility was observed for the PCr recovery rate constant (CV = 4.6%, ICC = 0.85) and calculated oxidative capacity (CV = 3.4%, ICC = 0.83). Conclusion These results indicate that 31P-MRS corresponds well with gold-standard in vitro measurements and is highly reproducible. PMID:22006551
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
Following the Department of Energy`s announcement in April 1985 that three Tennessee sites were to be considered for the Monitored Retrievable Storage facility, Governor Lamar Alexander initiated a review of the proposal to be coordinated by his Safe Growth Team. Roane County and the City of Oak Ridge, the local governments sharing jurisdiction over DOE`s primary and secondary sites, were invited to participate in the state`s review of the MRS proposal. Many issues related to the proposed MRS are being considered by the Governor`s Safe Growth Team. The primary objective of the Clinch River MRS Task Force has been tomore » determine whether the proposed Monitored Retrievable Storage facility should be accepted by the local governments, and if so, under what conditions. The Clinch River MRS Task Force is organized into an Executive Committee cochaired by the Roane County Executive and Mayor of Oak Ridge and three Study Groups focusing on environmental (including health and safety), socioeconomic, and transportation issues.« less
Diffusion Weighted MRI and MRS to Differentiate Radiation Necrosis and Recurrent Disease in Gliomas
NASA Astrophysics Data System (ADS)
Ewell, Lars
2006-03-01
A difficulty encountered in the diagnosis of patients with gliomas is the differentiation between recurrent disease and Radiation Induced Necrosis (RIN). Both can appear as ‘enhancing lesions’ on a typical T2 weighted MRI scan. Magnetic Resonance Spectroscopy (MRS) and Diffusion Weighted MRI (DWMRI) have the potential to be helpful regarding this differentiation. MRS has the ability to measure the concentration of brain metabolites, such as Choline, Creatin and N- Acetyl Aspartate, the ratios of which have been shown to discriminate between RIN and recurrent disease. DWMRI has been linked via a rise in the Apparent Diffusion Coefficient (ADC) to successful treatment of disease. Using both of these complimentary non-invasive imaging modalities, we intend to initiate an imaging protocol whereby we will study how best to combine metabolite ratios and ADC values to obtain the most useful information in the least amount of scan time. We will look for correlations over time between ADC values, and MRS, among different sized voxels.
[Psychometric assessment of a brief Modern Racism Scale].
Campo-Arias, Adalberto; Herazo, Edwin; Oviedo, Heidi C
2016-06-01
Objective To find the internal consistency of the Modern Racism Scale (MRS) among medical students in Bucaramanga, Colombia. Methods A total of 352 medical students, mean age=20.0 years (SD=1.9) reported their attitudes towards Afro-Colombians; 59.4 % were women. Students completed the 10-item version of MRS. Cronbach alpha and McDonald omega were calculated. Exploratory factor analyses were done to propose a brief version of the MRS. Results The 10-item version showed a Cronbach alpha of 0.48 and a McDonald omega of 0.15. The short version, the Brief Modern Racism Scale (BMRS) (items 1, 4, 5, 7 and 8) presented a Cronbach alpha of 0.64 and McDonald omega of 0.65. The BMRS showed one salient factor responsible of 41.6 % of the total variance. Conclusions A Spanish-language short version of the MRS shows better psychometric performance than the original version. Further study is needed to corroborate these findings or make adjustments for Colombian cultural regions.
Kasthurirathne, Suranga N; Mamlin, Burke; Grieve, Grahame; Biondich, Paul
2015-01-01
Interoperability is essential to address limitations caused by the ad hoc implementation of clinical information systems and the distributed nature of modern medical care. The HL7 V2 and V3 standards have played a significant role in ensuring interoperability for healthcare. FHIR is a next generation standard created to address fundamental limitations in HL7 V2 and V3. FHIR is particularly relevant to OpenMRS, an Open Source Medical Record System widely used across emerging economies. FHIR has the potential to allow OpenMRS to move away from a bespoke, application specific API to a standards based API. We describe efforts to design and implement a FHIR based API for the OpenMRS platform. Lessons learned from this effort were used to define long term plans to transition from the legacy OpenMRS API to a FHIR based API that greatly reduces the learning curve for developers and helps enhance adhernce to standards.
Lindner, Michael; Bell, Tiffany; Iqbal, Somya; Mullins, Paul Gerald
2017-01-01
Cortical acetylcholine is involved in key cognitive processes such as visuospatial attention. Dysfunction in the cholinergic system has been described in a number of neuropsychiatric disorders. Levels of brain acetylcholine can be pharmacologically manipulated, but it is not possible to directly measure it in vivo in humans. However, key parts of its biochemical cascade in neural tissue, such as choline, can be measured using magnetic resonance spectroscopy (MRS). There is evidence that levels of choline may be an indirect but proportional measure of acetylcholine availability in brain tissue. In this study, we measured relative choline levels in the parietal cortex using functional (event-related) MRS (fMRS) during performance of a visuospatial attention task, with a modelling approach verified using simulated data. We describe a task-driven interaction effect on choline concentration, specifically driven by contralateral attention shifts. Our results suggest that choline MRS has the potential to serve as a proxy of brain acetylcholine function in humans. PMID:28192451
Li, Ruizhi; Diamond, Scott L.
2014-01-01
BACKGROUND Microfluidic devices recreate the hemodynamic conditions of thrombosis. METHODS Whole blood inhibited with PPACK was treated ex vivo with inhibitors and perfused over collagen for 300 s (wall shear rate = 200 s−1) using a microfluidic flow assay. Platelet accumulation was measured in the presence of COX-1 inhibitor (aspirin, ASA), P2Y1 inhibitor (MRS 2179), P2Y12 inhibitor (2MeSAMP) or combined P2Y1 and P2Y12 inhibitors. RESULTS High dose ASA (500 μM), 2MeSAMP (100 μM), MRS 2179 (10 μM),or combined 2MeSAMP and MRS 2179 decreased total platelet accumulation by 27.5%, 75.6%, 77.7%, and 87.9% (p < 0.01), respectively. ASA reduced secondary aggregation rate between 150 and 300 s without effect on primary deposition rate on collagen from 60 to 150 s. In contrast, 2MeSAMP and MRS 2179 acted earlier and reduced primary deposition to collagen between 60 and 105 s and secondary aggregation between 105 and 300 s. RCOX and RP2Y (defined as a ratio of secondary aggregation rate to primary deposition rate) demonstrated 9 of 10 subjects had RCOX < 1 or RP2Y < 1 following ASA or 2MeSAMP addition, while 6 of 10 subjects had RP2Y < 1 following MRS 2179 addition. Combined MRS 2179 and 2MeSAMP inhibited primary platelet deposition rate and platelet secondary aggregation beyond that of each individual inhibitor. Receiver-Operator Characteristic area under the curve (AUC) indicated the robustness of RCOX and RP2Y to detect inhibition of secondary platelet aggregation by ASA, 2MeSAMP, and MRS 2179 (AUC of 0.874 0.966, and 0.889, respectively). CONCLUSIONS Microfluidic devices can detect platelet sensitivity to antiplatelet agents. The R-value can serve as a self-normalized metric of platelet function for a single blood sample. PMID:24365044
Lin, Chih-Ming; Chang, Yu-Jun; Liu, Chi-Kuang; Yu, Cheng-Sheng; Lu, Henry Horng-Shing
2016-01-01
Age is an important risk factor for stroke, and carotid artery stenosis is the primary cause of first-ever ischemic stroke. Timely intervention with stenting procedures can effectively prevent secondary stroke; however, the impact of stenting on various periprocedural physical functionalities has never been thoroughly investigated. The primary aim of this study was to investigate whether prestenting characteristics were associated with long-term functional outcomes in patients presenting with first-ever ischemic stroke. The secondary aim was to investigate whether patient age was an important factor in outcomes following stenting, measured by the modified Rankin scale (mRS). In total, 144 consecutive patients with first-ever ischemic stroke who underwent carotid artery stenting from January 2010 to November 2014 were included. Clinical data were obtained by review of medical records. The Barthel index (BI) and mRS were used to assess disability before stenting and at 12-month follow-up. In total, 72/144 patients showed improvement (mRS[+]), 71 showed stationary and one showed deterioration in condition (mRS[−]). The prestenting parameters, ratio of cerebral blood volume (1.41 vs 1.2 for mRS[−] vs mRS[+]), BI (75 vs 85), and high-sensitivity C-reactive protein (hsCRP 5.0 vs 3.99), differed significantly between the two outcome groups (P<0.05). The internal carotid artery/common carotid artery ratio (P=0.011), BI (P=0.019), ipsilateral internal carotid artery resistance index (P=0.003), and HbA1c (P=0.039) were all factors significantly associated with patient age group. There was no significant association between age and poststenting outcome measured by mRS with 57% of patients in the ≥75 years age group showing mRS(−) and 43% showing mRS(+) (P=0.371). Our findings indicate that in our elderly patient series, carotid artery stenting may benefit a significant proportion of carotid stenotic patients regardless of age. Ratio of cerebral blood volume, BI, and admission hsCRP could serve as important predictors of mRS improvement and may facilitate differentiation of patients at baseline. PMID:27555753
Utility-Weighted Modified Rankin Scale as Primary Outcome in Stroke Trials
Voormolen, Daphne C.; Venema, Esmee; Roozenbeek, Bob; Polinder, Suzanne; Haagsma, Juanita A.; Nieboer, Daan; Chalos, Vicky; Yoo, Albert J.; Schreuders, Jennifer; van der Lugt, Aad; Majoie, Charles B.L.M.; Roos, Yvo B.W.E.M.; van Zwam, Wim H.; van Oostenbrugge, Robert J.; Steyerberg, Ewout W.; Dippel, Diederik W.J.; Lingsma, Hester F.
2018-01-01
Background and Purpose— The utility-weighted modified Rankin Scale (UW-mRS) has been proposed as a new patient-centered primary outcome in stroke trials. We aimed to describe utility weights for the mRS health states and to evaluate the statistical efficiency of the UW-mRS to detect treatment effects in stroke intervention trials. Methods— We used data of the 500 patients enrolled in the MR CLEAN (Multicenter Randomized Clinical Trial of Endovascular Treatment for Acute Ischemic Stroke in the Netherlands). Utility values were elicited from the EuroQol Group 5-Dimension Self-Report Questionnaire assessed at 90 days after inclusion, simultaneously with the mRS. Utility weights were determined by averaging the utilities of all patients within each mRS category. We performed simulations to evaluate statistical efficiency. The simulated treatment effect was an odds ratio of 1.65 in favor of the treatment arm, similar for all mRS cutoffs. This treatment effect was analyzed using 3 approaches: linear regression with the UW-mRS as outcome, binary logistic regression with a dichotomized mRS (0–1/2–6, 0–2/3–6, and 0–4/5–6), and proportional odds logistic regression with the ordinal mRS. The statistical power of the 3 approaches was expressed as the proportion of 10 000 simulations that resulted in a statistically significant treatment effect (P≤0.05). Results— The mean utility values (SD) for mRS categories 0 to 6 were: 0.95 (0.08), 0.93 (0.13), 0.83 (0.21), 0.62 (0.27), 0.42 (0.28), 0.11 (0.28), and 0 (0), respectively, but varied substantially between individual patients within each category. The UW-mRS approach was more efficient than the dichotomous approach (power 85% versus 71%) but less efficient than the ordinal approach (power 85% versus 87%). Conclusions— The UW-mRS as primary outcome does not capture individual variation in utility values and may reduce the statistical power of a randomized trial. PMID:29535271
Multispectral Resource Sampler Workshop
NASA Technical Reports Server (NTRS)
1979-01-01
The utility of the multispectral resource sampler (MRS) was examined by users in the following disciplines: agriculture, atmospheric studies, engineering, forestry, geology, hydrology/oceanography, land use, and rangelands/soils. Modifications to the sensor design were recommended and the desired types of products and number of scenes required per month were indicated. The history, design, capabilities, and limitations of the MRS are discussed as well as the multilinear spectral array technology which it uses. Designed for small area inventory, the MRS can provide increased temporal, spectral, and spatial resolution, facilitate polarization measurement and atmospheric correction, and test onboard data compression techniques. The advantages of using it along with the thematic mapper are considered.
Barnes, Agnieszka Szot; Haker, Steven J; Mulkern, Robert V; So, Minna; D'Amico, Anthony V; Tempany, Clare M
2005-12-01
Brachytherapy targeted to the peripheral zone with magnetic resonance imaging (MRI) guidance is a prostate cancer treatment option with potentially fewer complications than other treatments. Follow-up MRI when failure is suspected is, however, difficult because of radiation-induced changes. Furthermore, MR spectroscopy (MRS) is compromised by susceptibility artifacts from radioactive seeds in the peripheral zone. We report a case in which combined MRI/MRS was useful for the detection of prostate cancer in the transitional zone in patients previously treated with MR-guided brachytherapy. We propose that MRI/MRS can help detect recurrent prostate cancer, guide prostate biopsy, and help manage salvage treatment decisions.
15. Photocopy of 1872 photograph by Eadweard Muybridge in Stanford ...
15. Photocopy of 1872 photograph by Eadweard Muybridge in Stanford University Archives, PC 6. BASEMENT BILLIARD ROOM, LOOKING SOUTH. LEFT TO RIGHT, LELAND STANFORD, JR., MRS. LELAND STANFORD AND ANNA MARIA LATHROP (MRS. STANFORD'S SISTER) - Leland Stanford House, 800 N Street, Sacramento, Sacramento County, CA
Choi, Seongjin; Reiter, David A; Shardell, Michelle; Simonsick, Eleanor M; Studenski, Stephanie; Spencer, Richard G; Fishbein, Kenneth W; Ferrucci, Luigi
2016-12-01
Aerobic fitness and muscle bioenergetic capacity decline with age; whether such declines explain age-related slowing of walking speed is unclear. We hypothesized that muscle energetics and aerobic capacity are independent correlates of walking speed in simple and challenging performance tests and that they account for the observed age-related decline in walking speed in these same tests. Muscle bioenergetics was assessed as postexercise recovery rate of phosphocreatine (PCr), k PCr , using phosphorus magnetic resonance spectroscopy ( 31 P-MRS) in 126 participants (53 men) of the Baltimore Longitudinal Study of Aging aged 26-91 years (mean = 72 years). Four walking tasks were administered-usual pace over 6 m and 150 seconds and fast pace over 6 m and 400 m. Separately, aerobic fitness was assessed as peak oxygen consumption (peak VO 2 ) using a graded treadmill test. All gait speeds, k PCr , and peak VO 2 were lower with older age. Independent of age, sex, height, and weight, both k PCr and peak VO 2 were positively and significantly associated with fast pace and long distance walking but only peak VO 2 and not k PCr was significantly associated with usual gait speed over 6 m. Both k PCr and peak VO 2 substantially attenuated the association between age and gait speed for all but the least stressful walking task of 6 m at usual pace. Muscle bioenergetics assessed using 31 P-MRS is highly correlated with walking speed and partially explains age-related poorer performance in fast and long walking tasks. Published by Oxford University Press on behalf of The Gerontological Society of America 2016. This work is written by (a) US Government employee(s) and is in the public domain in the US.
Moreira, João Luiz S; Mota, Rodrigo M; Horta, Maria F; Teixeira, Santuza MR; Neumann, Elisabeth; Nicoli, Jacques R; Nunes, Álvaro C
2005-01-01
Background The accurate identification of Lactobacillus and other co-isolated bacteria during microbial ecological studies of ecosystems such as the human or animal intestinal tracts and food products is a hard task by phenotypic methods requiring additional tests such as protein and/or lipids profiling. Results Bacteria isolated in different probiotic prospecting studies, using de Man, Rogosa and Sharpe medium (MRS), were typed at species level by PCR amplification of 16S-23S rRNA intergenic spacers using universal primers that anneal within 16S and 23S genes, followed by restriction digestion analyses of PCR products. The set of enzymes chosen differentiates most species of Lactobacillus genus and also co-isolated bacteria such as Enterococcus, Streptococcus, Weissella, Staphylococcus, and Escherichia species. The in silico predictions of restriction patterns generated by the Lactobacillus shorter spacers digested with 11 restriction enzymes with 6 bp specificities allowed us to distinguish almost all isolates at the species level but not at the subspecies one. Simultaneous theoretical digestions of the three spacers (long, medium and short) with the same set of enzymes provided more complex patterns and allowed us to distinguish the species without purifying and cloning of PCR products. Conclusion Lactobacillus isolates and several other strains of bacteria co-isolated on MRS medium from gastrointestinal ecosystem and fermented food products could be identified using DNA fingerprints generated by restriction endonucleases. The methodology based on amplified ribosomal DNA restriction analysis (ARDRA) is easier, faster and more accurate than the current methodologies based on fermentation profiles, used in most laboratories for the purpose of identification of these bacteria in different prospecting studies. PMID:15788104
Liu, Haisheng; Ma, Linbin; Ma, Changbei; Du, Junyan; Wang, Meilan; Wang, Kemin
2016-11-18
A new quencher-free Hg 2+ ion assay method was developed based on polymerase-assisted photoinduced electron transfer (PIET). In this approach, a probe is designed with a mercury ion recognition sequence (MRS) that is composed of two T-rich functional areas separated by a spacer of random bases at the 3'-end, and a sequence of stacked cytosines at the 5'-end, to which a fluorescein (FAM) is attached. Upon addition of Hg 2+ ions into this sensing system, the MRS folds into a hairpin structure at the 3'-end with Hg 2+ -mediated base pairs. In the presence of DNA polymerase, it will catalyze the extension reaction, resulting in the formation of stacked guanines, which will instantly quench the fluorescence of FAM through PIET. Under optimal conditions, the limit of detection for Hg 2+ ions was estimated to be 5 nM which is higher than the US Environmental Protection Agency (EPA) standard limit. In addition, no labeling with a quencher was requiring, and the present method is fairly simple, fast and low cost. It is expected that this cost-effective fluorescence method might hold considerable potential in the detection of Hg 2+ ions in real biological and environmental samples.
Onuki, Yoshinori; Horita, Akihiro; Kuribayashi, Hideto; Okuno, Yoshihide; Obata, Yasuko; Takayama, Kozo
2014-07-01
A non-destructive method for monitoring creaming of emulsion-based formulations is in great demand because it allows us to understand fully their instability mechanisms. This study was aimed at demonstrating the usefulness of magnetic resonance (MR) techniques, including MR imaging (MRI) and MR spectroscopy (MRS), for evaluating the physicochemical stability of emulsion-based formulations. Emulsions that are applicable as the base of practical skin creams were used as test samples. Substantial creaming was developed by centrifugation, which was then monitored by MRI. The creaming oil droplet layer and aqueous phase were clearly distinguished by quantitative MRI by measuring T1 and the apparent diffusion coefficient. Components in a selected volume in the emulsions could be analyzed using MRS. Then, model emulsions having different hydrophilic-lipophilic balance (HLB) values were tested, and the optimal HLB value for a stable dispersion was determined. In addition, the MRI examination enables the detection of creaming occurring in a polyethylene tube, which is commonly used for commercial products, without losing any image quality. These findings strongly indicate that MR techniques are powerful tools to evaluate the physicochemical stability of emulsion-based formulations. This study will make a great contribution to the development and quality control of emulsion-based formulations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brame, Ryan S.; Zaider, Marco; Zakian, Kristen L.
2009-05-01
Purpose: To quantify, as a function of average magnetic resonance spectroscopy (MRS) score and tumor volume, the probability that a cancer-suspected lesion has an elevated Gleason grade. Methods and Materials: The data consist of MRS imaging ratios R stratified by patient, lesion (contiguous abnormal voxels), voxels, biopsy and pathologic Gleason grade, and lesion volume. The data were analyzed using a logistic model. Results: For both low and high Gleason score biopsy lesions, the probability of pathologic Gleason score {>=}4+3 increases with lesion volume. At low values of R a lesion volume of at least 15-20 voxels is needed to reachmore » a probability of success of 80%; the biopsy result helps reduce the prediction uncertainty. At larger MRS ratios (R > 6) the biopsy result becomes essentially uninformative once the lesion volume is >12 voxels. With the exception of low values of R, for lesions with low Gleason score at biopsy, the MRS ratios serve primarily as a selection tool for assessing lesion volumes. Conclusions: In patients with biopsy Gleason score {>=}4+3, high MRS imaging tumor volume and (creatine + choline)/citrate ratio may justify the initiation of voxel-specific dose escalation. This is an example of biologically motivated focal treatment for which intensity-modulated radiotherapy and especially brachytherapy are ideally suited.« less
Wang, Tao; Chen, Pingyang; Bian, Dujun; Chen, Juncao
2017-04-01
Proton magnetic resonance spectroscopy ( 1 H-MRS) measurement of liver metabolism in intrauterine growth restriction rats has seldom been reported. This study investigated the application of 1 H-MRS in assessing liver metabolism in newborn pups that experienced intrauterine growth restriction. Intra-uterine growth restriction was established by feeding rats low-protein diets during pregnancy. Newborn pups received conventional magnetic resonance imaging and 1 H-MRS using a 3.0T whole body MR scanner at 3, 8 and 12 weeks post birth. The success rate of 1 H-MRS was 83.33%. Significantly lower body weight, BMI and body length at 3 weeks as well as significantly lower body weight, BMI and waist circumference at 8 and 12 weeks were observed in newborn pups of IUGR rats compared with pups of control rats. Significant differences in ACho/H 2 O, ACr/H 2 O, AGlx/H 2 O and ALipid/H 2 O at 3 and 8 weeks as well as significant differences in ACr/H 2 O, ALipid/H 2 O and AGlx/H 2 O at 12 weeks were observed between pups of control rats and pups of IUGR rats. 1 H-MRS allows noninvasive assessment of liver metabolism in the rat and demonstrated the poor liver development of rats that experienced IUGR.
Oeltzschner, Georg; Zöllner, Helge J; Jonuscheit, Marc; Lanzman, Rotem S; Schnitzler, Alfons; Wittsack, Hans-Jörg
2018-05-12
The aim of this study was to investigate potential effects of acute caffeine intake on J-difference-edited MRS measures of the primary inhibitory neurotransmitter γ-aminobutyric acid (GABA). J-difference-edited Mescher-Garwood PRESS (MEGA-PRESS) and conventional PRESS data were acquired at 3T from voxels in the anterior cingulate and occipital area of the brain in 15 healthy subjects, before and after oral intake of a 200-mg caffeine dose. MEGA-PRESS data were analyzed with the MATLAB-based Gannet tool to estimate GABA+ macromolecule (GABA+) levels, while PRESS data were analyzed with LCModel to estimate levels of glutamate, glutamate+glutamine, N-acetylaspartate, and myo-inositol. All metabolites were quantified with respect to the internal reference compounds creatine and tissue water, and compared between the pre- and post-caffeine intake condition. For both MRS voxels, mean GABA+ estimates did not differ before and after caffeine intake. Slightly lower estimates of myo-inositol were observed after caffeine intake in both voxels. N-acetylaspartate, glutamate, and glutamate+glutamine did not show significant differences between conditions. Mean GABA+ estimates from J-difference-edited MRS in two different brain regions are not altered by acute oral administration of caffeine. These findings may increase subject recruitment efficiency for MRS studies. © 2018 International Society for Magnetic Resonance in Medicine.
Chemical shift-based MRI to measure fat fractions in dystrophic skeletal muscle
Triplett, William T.; Baligand, Celine; Forbes, Sean C.; Willcocks, Rebecca J.; Lott, Donovan J.; DeVos, Soren; Pollaro, Jim; Rooney, William D.; Sweeney, H. Lee; Bönnemann, Carsten; Wang, Dah-Jyuu; Vandenborne, Krista; Walter, Glenn A.
2014-01-01
Purpose The relationship between FF determined based on multiple TE, unipolar GE images and 1H-MRS was evaluated using different models for fat-water decomposition, signal-to-noise ratios (SNR), and excitation flip angles. Methods A combination of single voxel proton spectroscopy (1H-MRS) and gradient echo (GE) imaging was used to determine muscle fat fractions (FF) in both normal and dystrophic muscles. In order to cover a large range of FF, the soleus and vastus lateralis muscles of 22 unaffected control (CON), 16 subjects with Collagen VI (COL6), and 71 subjects with Duchenne muscular dystrophy (DMD) were studied. 1H-MRS based FF were corrected for the increased muscle 1H2O T1 and T2 values observed in dystrophic muscles. Results Excellent agreement was found between co-registered FF derived from GE images fit to a multipeak model with noise bias correction and the relaxation corrected 1H-MRS FF (y= 0.93×+0.003; R2=0.96) across the full range of FF. Relaxation corrected 1H-MRS FF and imaging based FF were significantly elevated (p<0.01) in both COL6 and DMD muscles. Conclusion FF, T2, and T1 were all sensitive to muscle involvement in dystrophic muscle. MRI offered an additional advantage over single voxel spectroscopy in that the tissue heterogeneity in FF could be readily determined. PMID:24006208
Childs, Charmaine; Hiltunen, Yrjö; Vidyasagar, Rishma; Kauppinen, Risto A
2007-01-01
Proton magnetic resonance spectroscopy ((1)H MRS) was used to determine brain temperature in healthy volunteers. Partially water-suppressed (1)H MRS data sets were acquired at 3T from four different gray matter (GM)/white matter (WM) volumes. Brain temperatures were determined from the chemical-shift difference between the CH(3) of N-acetyl aspartate (NAA) at 2.01 ppm and water. Brain temperatures in (1)H MRS voxels of 2 x 2 x 2 cm(3) showed no substantial heterogeneity. The volume-averaged temperature from single-voxel spectroscopy was compared with body temperatures obtained from the oral cavity, tympanum, and temporal artery regions. The mean brain parenchyma temperature was 0.5 degrees C cooler than readings obtained from three extra-brain sites (P < 0.01). (1)H MRS imaging (MRSI) data were acquired from a slice encompassing the single-voxel volumes to assess the ability of spectroscopic imaging to determine regional brain temperature within the imaging slice. Brain temperature away from the center of the brain determined by MRSI differed from that obtained by single-voxel MRS in the same brain region, possibly due to a poor line width (LW) in MRSI. The data are discussed in the light of proposed brain-body temperature gradients and the use of (1)H MRSI to monitor brain temperature in pathologies, such as brain trauma.
Shao, Xiao-Li; Zhou, Zhong-Shu; Hong, Wen
2010-06-01
This study examined the biochemical metabolism by proton magnetic resonance spectroscopy ('H-MRS) in order to explore the value of 'H-MRS in idiopathic epilepsy in children. Thirty-three children with idiopathic epilepsy (14 cases with history of febrile seizures and 19 cases without) and six normal controls experienced MRI of the skull and brain and single-voxel 'H-MRS examinations of the hippocampi-temporal lobe. The signal intensities of N-acetylaspartate (NAA), eatine+phosphocreatine (Cr), choline-containing compounds (Cho) and lactate (Lac) and the ratios of NAA/ (Cho+Cr) and Lac/Cr were compared between the patients and normal controls. MRI examination showed that only one child with epilepsy had myelin dysplasia. 'H-MRS examination showed that the ratio of NAA/ (Cho+Cr) in the epilepsy group was lower than that in the control group (0.64+/-0.07 vs 0.73+/-0.05; P<0.01). The epileptic children with history of febrile seizures had a more decreased ratio of NAA/ (Cho+Cr) compared with those without the history (0.61+/-0.07 vs 0.66+/-0.06; P<0.05). There were no significant differences in the ratio of Lac/Cr between the epilepsy and the control groups. 'H-MRS may provide early information on brain injury sensitively and non-invasively in children with epilepsy. It may be used for diagnosis and prognosis evaluation of epilepsy.
10 CFR 72.90 - General considerations.
Code of Federal Regulations, 2012 CFR
2012-01-01
..., HIGH-LEVEL RADIOACTIVE WASTE, AND REACTOR-RELATED GREATER THAN CLASS C WASTE Siting Evaluation Factors... environmental impact of the ISFSI or MRS must be investigated and assessed. (b) Proposed sites for the ISFSI or... proposed site for an MRS, the potential for radiological and other environmental impacts on the region must...
10 CFR 72.90 - General considerations.
Code of Federal Regulations, 2011 CFR
2011-01-01
..., HIGH-LEVEL RADIOACTIVE WASTE, AND REACTOR-RELATED GREATER THAN CLASS C WASTE Siting Evaluation Factors... environmental impact of the ISFSI or MRS must be investigated and assessed. (b) Proposed sites for the ISFSI or... proposed site for an MRS, the potential for radiological and other environmental impacts on the region must...
Major Re-Selection Advising and Academic Performance
ERIC Educational Resources Information Center
McKenzie, Deborah; Tan, Tony Xing; Fletcher, Edward C.; Jackson-Williams, Andrea
2017-01-01
We sought to determine whether receiving major re-selection (MRS) advising benefits undergraduate students' grade-point averages (GPAs). We used a quasi-experimental nonequivalent control group design to compare a treatment group (n = 219) of undergraduates who changed their majors after receiving MRS advising with a control group (n = 206) who…
10 CFR 72.75 - Reporting requirements for specific events and conditions.
Code of Federal Regulations, 2010 CFR
2010-01-01
... information related to ISFSI or MRS behavior that is not understood. (3) Maintain an open, continuous communication channel with the NRC Headquarters Operations Center upon request by the NRC. (g) Preparation and... MRS, but not familiar with the details of a particular facility, can understand the complete event...
Oza, Shefali; Jazayeri, Darius; Teich, Jonathan M; Ball, Ellen; Nankubuge, Patricia Alexandra; Rwebembera, Job; Wing, Kevin; Sesay, Alieu Amara; Kanter, Andrew S; Ramos, Glauber D; Walton, David; Cummings, Rachael; Checchi, Francesco; Fraser, Hamish S
2017-08-21
Stringent infection control requirements at Ebola treatment centers (ETCs), which are specialized facilities for isolating and treating Ebola patients, create substantial challenges for recording and reviewing patient information. During the 2014-2016 West African Ebola epidemic, paper-based data collection systems at ETCs compromised the quality, quantity, and confidentiality of patient data. Electronic health record (EHR) systems have the potential to address such problems, with benefits for patient care, surveillance, and research. However, no suitable software was available for deployment when large-scale ETCs opened as the epidemic escalated in 2014. We present our work on rapidly developing and deploying OpenMRS-Ebola, an EHR system for the Kerry Town ETC in Sierra Leone. We describe our experience, lessons learned, and recommendations for future health emergencies. We used the OpenMRS platform and Agile software development approaches to build OpenMRS-Ebola. Key features of our work included daily communications between the development team and ground-based operations team, iterative processes, and phased development and implementation. We made design decisions based on the restrictions of the ETC environment and regular user feedback. To evaluate the system, we conducted predeployment user questionnaires and compared the EHR records with duplicate paper records. We successfully built OpenMRS-Ebola, a modular stand-alone EHR system with a tablet-based application for infectious patient wards and a desktop-based application for noninfectious areas. OpenMRS-Ebola supports patient tracking (registration, bed allocation, and discharge); recording of vital signs and symptoms; medication and intravenous fluid ordering and monitoring; laboratory results; clinician notes; and data export. It displays relevant patient information to clinicians in infectious and noninfectious zones. We implemented phase 1 (patient tracking; drug ordering and monitoring) after 2.5 months of full-time development. OpenMRS-Ebola was used for 112 patient registrations, 569 prescription orders, and 971 medication administration recordings. We were unable to fully implement phases 2 and 3 as the ETC closed because of a decrease in new Ebola cases. The phase 1 evaluation suggested that OpenMRS-Ebola worked well in the context of the rollout, and the user feedback was positive. To our knowledge, OpenMRS-Ebola is the most comprehensive adaptable clinical EHR built for a low-resource setting health emergency. It is designed to address the main challenges of data collection in highly infectious environments that require robust infection prevention and control measures and it is interoperable with other electronic health systems. Although we built and deployed OpenMRS-Ebola more rapidly than typical software, our work highlights the challenges of having to develop an appropriate system during an emergency rather than being able to rapidly adapt an existing one. Lessons learned from this and previous emergencies should be used to ensure that a set of well-designed, easy-to-use, pretested health software is ready for quick deployment in future. ©Shefali Oza, Darius Jazayeri, Jonathan M Teich, Ellen Ball, Patricia Alexandra Nankubuge, Job Rwebembera, Kevin Wing, Alieu Amara Sesay, Andrew S Kanter, Glauber D Ramos, David Walton, Rachael Cummings, Francesco Checchi, Hamish S Fraser. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 21.08.2017.
Stefanati, Armando; Brosio, Federica; Kuhdari, Parvanè; Baccello, Valeria; De Paris, Paola; Nardini, Marco; Boschetto, Piera; Lupi, Silvia; Gabutti, Giovanni
2017-01-01
The hospital as a work environment is particularly characterized by various risks for healthcare workers (HCWs). The main risk is represented by biological accidents, associated with the parenteral transmission of pathogens. Biological injuries can occur during the care service and the manipulation of biological fluids. Hepatitis B (and hepatitis D), hepatitis C and HIV are the most common infections transmitted by biological injuries. Physicians should acquire awareness of the risks associated with their professional activity during their training as medical residents (MRs). Some infectious diseases are preventable by vaccination and the "National Immunization Plan 2017-2019" (PNPV) recommends HCWs vaccination against hepatitis B, influenza, measles -mumps -rubella, chicken pox, and pertussis. Besides, not only HCWs' vaccination can prevent the disease in healthcare professionals, but it also may reduce the transmission to patients. Therefore, active immunization of HCWs by recommended vaccinations plays an important role to prevent disease cases, complications and death in patients. An increased awareness of risk behaviors is the first important point to address in order to reduce biological accidents and infectious diseases transmission, so as to reduce their frequency. Besides, HCWs' vaccination is useful to reinforce protection and to prevent the transmission of some infectious diseases in case of exposure. The aim of this five-year incidence study is to investigate the MRs' biological accidents characteristics and to analyze the MRs' immune status at the University of Ferrara in the period 2011-2015. Data on MRs' biological accidents and immune status at Azienda Ospedaliero-Universitaria of Ferrara in 2011-2015 were analyzed by Microsoft Excel 2007 Software. In this study, the percentage of MRs' biological injuries compared to the total number of MRs showed an annual variability, with a peak in 2011 (11.9%). During the analyzed period, there were 190 biological injuries among the MRs: 81% were percutaneous injuries and blood was the biological fluid involved in 86.3% of cases. The most frequent lesion was puncture (62.6%), occurred in 41.1% of cases by suture needles; 46.3% of accidents occurred in the operating block. These data can be explained by the more invasive and at risk activities carried out in these Operative Units. The high injuries percentage in MRs may be related to less work experience and inadequate training or informations about personal protective equipment use. Among MRs, 93.7%, 93.3% and 96.6% were immune to measles, chicken pox and hepatitis B, respectively; only in the case of rubella, 11.9% of MRs was not immune. This research showed, accordingly to published data, high adhesion to hepatitis B vaccination. However, the healthcare workers' vaccine coverage is still sub-optimal; active immunization by recommended vaccines should be implemented for both parenteral and airborne diseases. As a matter of fact, the recent measles outbreak has involved healthcare workers (4689 cases of measles, 305 in HCWs). Finally, the General Directorates of Health-care settings should improve healthcare personnel adhesion to vaccinations, such as influenza, by promotion activities in the workplace. A proposal in order to achieve coverage objectives could be making vaccinations mandatory, as well as already implemented in other countries.
Quantifying global-brain metabolite level changes with whole-head proton MR spectroscopy at 3T.
Davitz, Matthew S; Wu, William E; Soher, Brian J; Babb, James S; Kirov, Ivan I; Huang, Jeffrey; Fatterpekar, Girish; Gonen, Oded
2017-01-01
To assess the sensitivity of non-localized, whole-head 1 H-MRS to an individual's serial changes in total-brain NAA, Glx, Cr and Cho concentrations - metabolite metrics often used as surrogate markers in neurological pathologies. In this prospective study, four back-to-back (single imaging session) and three serial (successive sessions) non-localizing, ~3min 1 H-MRS (TE/TR/TI=5/10 4 /940ms) scans were performed on 18 healthy young volunteers: 9 women, 9 men: 29.9±7.6 [mean±standard deviation (SD)] years old. These were analyzed by calculating a within-subject coefficient of variation (CV=SD/mean) to assess intra- and inter-scan repeatability and prediction intervals. This study was Health Insurance Portability and Accountability Act compliant. All subjects gave institutional review board-approved written, informed consent. The intra-scan CVs for the NAA, Glx, Cr and Cho were: 3.9±1.8%, 7.3±4.6%, 4.0±3.4% and 2.5±1.6%, and the corresponding inter-scan (longitudinal) values were: 7.0±3.1%, 10.6±5.6%, 7.6±3.5% and 7.0±3.9%. This method is shown to have 80% power to detect changes of 14%, 27%, 26% and 19% between two serial measurements in a given individual. Subject to the assumption that in neurological disorders NAA, Glx, Cr and Cho changes represent brain-only pathology and not muscles, bone marrow, adipose tissue or epithelial cells, this approach enables us to quantify them, thereby adding specificity to the assessment of the total disease load. This will facilitate monitoring diffuse pathologies with faster measurement, more extensive (~90% of the brain) spatial coverage and sensitivity than localized 1 H-MRS. Copyright © 2016 Elsevier Inc. All rights reserved.
Decreased occipital lobe metabolism by FDG-PET/CT
Solnes, Lilja; Nalluri, Abhinav; Cohen, Jesse; Jones, Krystyna M.; Zan, Elcin; Javadi, Mehrbod S.; Venkatesan, Arun
2017-01-01
Objective: To compare brain metabolism patterns on fluorodeoxyglucose (FDG)-PET/CT in anti–NMDA receptor and other definite autoimmune encephalitis (AE) and to assess how these patterns differ between anti–NMDA receptor neurologic disability groups. Methods: Retrospective review of clinical data and initial dedicated brain FDG-PET/CT studies for neurology inpatients with definite AE, per published consensus criteria, treated at a single academic medical center over a 10-year period. Z-score maps of FDG-PET/CT were made using 3-dimensional stereotactic surface projections in comparison to age group–matched controls. Brain region mean Z scores with magnitudes ≥2.00 were interpreted as significant. Comparisons were made between anti–NMDA receptor and other definite AE patients as well as among patients with anti–NMDA receptor based on modified Rankin Scale (mRS) scores at the time of FDG-PET/CT. Results: The medial occipital lobes were markedly hypometabolic in 6 of 8 patients with anti–NMDA receptor encephalitis and as a group (Z = −4.02, interquartile range [IQR] 2.14) relative to those with definite AE (Z = −2.32, 1.46; p = 0.004). Among patients with anti–NMDA receptor encephalitis, the lateral and medial occipital lobes were markedly hypometabolic for patients with mRS 4–5 (lateral occipital lobe Z = −3.69, IQR 1; medial occipital lobe Z = −4.08, 1) compared with those with mRS 0–3 (lateral occipital lobe Z = −0.83, 2; p < 0.0005; medial occipital lobe Z = −1.07, 2; p = 0.001). Conclusions: Marked medial occipital lobe hypometabolism by dedicated brain FDG-PET/CT may serve as an early biomarker for discriminating anti–NMDA receptor encephalitis from other AE. Resolution of lateral and medial occipital hypometabolism may correlate with improved neurologic status in anti–NMDA receptor encephalitis. PMID:29159205
Ramsden, R T; Barrett, A
1975-06-01
The uncommon familial syndrome of multiple odontogenic keratocysts, basal cell naevi and skeletal anomalies is reviewed, and seven cases are described, including one patient who developed squamous cell carcinoma in a previous odontogenic keratocyst of the maxilla. We wish to thank Consultants from the Royal National Throat, Nose and Ear Hospital, The Middlesex Hospital and the Eastman Dental Hospital, who allowed us access to their patients; Mr. D. Garfield Davies, Dr. M. F. Spittle, Mr. D. Winstock, Mr. H. P. Cook, Professor H. C. Killey and Mr. L. W. Kay. We are grateful to Professor L. Michaels and Mr. D. J. Connolly for preparation of the illustrations and to Mrs. A. Matthews for the typescript.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-25
... assembly attaching hardware with the high strength steel hardware for unmodified REL MRS because the...) should be extended for the MRS over life limit because the steel plates referenced in the service... mandate modifying the configuration using the steel plates in SB 61B35-53A, and therefore the availability...
Defense.gov Special Report: Warrior Games 2012
Department of Defense Submit Search April 2012 Warrior Games Once on the battlefield, now on the playing challenges amplify all of you." First Lady Michelle Obama Warrior Games Opening Ceremonies, April 30 Cycling Events Photo Essay: Mrs. Obama, Dempsey Attend Opening for 2012 Warrior Games Mrs. Obama, Dempsey
Working for the People? Mrs Bridges Adams and the London School Board, 1897-1904.
ERIC Educational Resources Information Center
Martin, Jane
2000-01-01
Focuses on Mrs. Bridges Adams who was a supporter of state maintenance committed to educational opportunity for workers' children. Focuses on her political recruitment, her contribution to the work of the London School Board (England), and her role in the struggle to save the school board system. (CMK)
Army Science Board (ASB) 1983 Summer Study on the Future Development Goal
1983-11-01
PARTICIPATED WITH ASB DR. ROGER 0. BOURKE JPL MR. ARTHUR C. CHRISTMAN TRADOC MAJ MICHAEL M. FERGUSON TRADOC DR. EDGAR M. JOHNSON ARI BG ROBERT B...MARGARET POTTER ASS MS. SHARON L. BERTONI ODCSOPS MS. BRENDA E. CALLAHAN OASAIRDA) MRS. SHARON J. LAYTON ODCSOPS MRS. MARY G. QUELLEIrE ODCSRDA I
Imaging Intelligence with Proton Magnetic Resonance Spectroscopy
ERIC Educational Resources Information Center
Jung, Rex E.; Gasparovic, Charles; Chavez, Robert S.; Caprihan, Arvind; Barrow, Ranee; Yeo, Ronald A.
2009-01-01
Proton magnetic resonance spectroscopy ([to the first power]H-MRS) is a technique for the assay of brain neurochemistry "in vivo." N-acetylaspartate (NAA), the most prominent metabolite visible within the [to the first power]H-MRS spectrum, is found primarily within neurons. The current study was designed to further elucidate NAA-cognition…
Circulant Matrices and Affine Equivalence of Monomial Rotation Symmetric Boolean Functions
2015-01-01
definitions , including monomial rotation symmetric (MRS) Boolean functions and affine equivalence, and a known result for such quadratic functions...degree of the MRS is, we have a similar result as [40, Theorem 1.1] for n = 4p (p prime), or squarefree integers n, which along with our Theorem 5.2
The American Odyssey of Maria Montessori.
ERIC Educational Resources Information Center
Kornegay, William
Dr. Maria Montessori's 1913 visit and lecture tour to the United SLates is described in detail with numerous citations from newspaper coverage of the event. The enthusiastic reception extended to the European physician and educator is reviewed, and her meetings, notably with Mr. and Mrs. Alexander Graham Bell, President and Mrs. Woodrow Wilson,…
ERIC Educational Resources Information Center
Graham, Renee Williams; Dennis, Emily; Cornell, Marilyn
2013-01-01
Students in Mrs. Cornell's kindergarten class shared their observations about what happened when drops of water were placed on different types of wood. The students were engaging in a science lesson focusing on the observable properties of wood, an activity from the FOSS Wood and Paper science module. This lesson is one of many that Mrs. Cornell…
Multispectral Resource Sampler: Proof of concept. Literature survey of bidirectional reflectance
NASA Technical Reports Server (NTRS)
1981-01-01
A bibliography compiled in order to give a comprehensive review of previous work in scene bidirectional reflectance, particularly those studies relevant to the Multispectral Resource Sampler (MRS) is presented. The bibliography contains 124 abstracts. In addition a synthesis of the literature results is given along with background information concerning MRS.
Sathyavathi, S; Manjula, A; Rajendhran, J; Gunasekaran, P
2014-08-01
In the present study, a nickel resistant bacterium MRS-1 was isolated from nickel electroplating industrial effluent, capable of converting soluble NiSO4 into insoluble NiO nanoparticles and identified as Microbacterium sp. The formation of NiO nanoparticles in the form of pale green powder was observed on the bottom of the flask upon prolonged incubation of liquid nutrient medium containing high concentration of 2000ppm NiSO4. The properties of the produced NiO nanoparticles were characterized. NiO nanoparticles exhibited a maximum absorbance at 400nm. The NiO nanoparticles were 100-500nm in size with unique flower like structure. The elemental composition of the NiO nanoparticles was 44:39. The cells of MRS-1 were utilized for the treatment of nickel electroplating industrial effluent and showed nickel removal efficiency of 95%. Application of Microbacterium sp. MRS-1 would be a potential bacterium for bioremediation of nickel electroplating industrial waste water and simultaneous synthesis of NiO nanoparticles. Copyright © 2014 Elsevier Ltd. All rights reserved.
Thiele, Ines; Hyduke, Daniel R; Steeb, Benjamin; Fankam, Guy; Allen, Douglas K; Bazzani, Susanna; Charusanti, Pep; Chen, Feng-Chi; Fleming, Ronan M T; Hsiung, Chao A; De Keersmaecker, Sigrid C J; Liao, Yu-Chieh; Marchal, Kathleen; Mo, Monica L; Özdemir, Emre; Raghunathan, Anu; Reed, Jennifer L; Shin, Sook-il; Sigurbjörnsdóttir, Sara; Steinmann, Jonas; Sudarsan, Suresh; Swainston, Neil; Thijs, Inge M; Zengler, Karsten; Palsson, Bernhard O; Adkins, Joshua N; Bumann, Dirk
2011-01-18
Metabolic reconstructions (MRs) are common denominators in systems biology and represent biochemical, genetic, and genomic (BiGG) knowledge-bases for target organisms by capturing currently available information in a consistent, structured manner. Salmonella enterica subspecies I serovar Typhimurium is a human pathogen, causes various diseases and its increasing antibiotic resistance poses a public health problem. Here, we describe a community-driven effort, in which more than 20 experts in S. Typhimurium biology and systems biology collaborated to reconcile and expand the S. Typhimurium BiGG knowledge-base. The consensus MR was obtained starting from two independently developed MRs for S. Typhimurium. Key results of this reconstruction jamboree include i) development and implementation of a community-based workflow for MR annotation and reconciliation; ii) incorporation of thermodynamic information; and iii) use of the consensus MR to identify potential multi-target drug therapy approaches. Taken together, with the growing number of parallel MRs a structured, community-driven approach will be necessary to maximize quality while increasing adoption of MRs in experimental design and interpretation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thiele, Ines; Hyduke, Daniel R.; Steeb, Benjamin
2011-01-01
Metabolic reconstructions (MRs) are common denominators in systems biology and represent biochemical, genetic, and genomic (BiGG) knowledge-bases for target organisms by capturing currently available information in a consistent, structured manner. Salmonella enterica subspecies I serovar Typhimurium is a human pathogen, causes various diseases and its increasing antibiotic resistance poses a public health problem. Here, we describe a community-driven effort, in which more than 20 experts in S. Typhimurium biology and systems biology collaborated to reconcile and expand the S. Typhimurium BiGG knowledge-base. The consensus MR was obtained starting from two independently developed MRs for S. Typhimurium. Key results of thismore » reconstruction jamboree include i) development and implementation of a community-based workflow for MR annotation and reconciliation; ii) incorporation of thermodynamic information; and iii) use of the consensus MR to identify potential multi-target drug therapy approaches. Finally, taken together, with the growing number of parallel MRs a structured, community-driven approach will be necessary to maximize quality while increasing adoption of MRs in experimental design and interpretation.« less
Interaction of magnetic resonators studied by the magnetic field enhancement
NASA Astrophysics Data System (ADS)
Hou, Yumin
2013-12-01
It is the first time that the magnetic field enhancement (MFE) is used to study the interaction of magnetic resonators (MRs), which is more sensitive than previous parameters-shift and damping of resonance frequency. To avoid the coherence of lattice and the effect of Bloch wave, the interaction is simulated between two MRs with same primary phase when the distance is changed in the range of several resonance wavelengths, which is also compared with periodic structure. The calculated MFE oscillating and decaying with distance with the period equal to resonance wavelength directly shows the retardation effect. Simulation also shows that the interaction at normal incidence is sensitive to the phase correlation which is related with retardation effect and is ultra-long-distance interaction when the two MRs are strongly localized. When the distance is very short, the amplitude of magnetic resonance is oppressed by the strong interaction and thus the MFE can be much lower than that of single MR. This study provides the design rules of metamaterials for engineering resonant properties of MRs.
A new metasurface reflective structure for simultaneous enhancement of antenna bandwidth and gain
NASA Astrophysics Data System (ADS)
Ullah, M. Habib; Islam, M. T.
2014-08-01
A new bi-layered metasurface reflective structure (MRS) on a high-permittivity, low-loss, ceramic-filled, bio-plastic, sandwich-structured, dielectric substrate is proposed for the simultaneous enhancement of the bandwidth and gain of a dual band patch antenna. By incorporating the MRS with a 4 mm air gap between the MRS and the antenna, the bandwidth and gain of the dual band patch antenna are significantly enhanced. The reflection coefficient (S11 < -10 dB) bandwidth of the proposed MRS-loaded antenna increased by 240% (178%), and the average peak gain improved by 595% (128%) compared to the antenna alone in the lower (upper) band. Incremental improvements of the magnitude and directional patterns have been observed from the measured radiation patterns at the three resonant frequencies of 0.9 GHz, 3.7 GHz and 4.5 GHz. The effects of different configurations of the radiating patch and the ground plane on the reflection coefficient have been analyzed. In addition, the voltage standing wave ratio and input impedance have also been validated using a Smith chart.
Hakkarainen, Antti; Puustinen, Lauri; Kivisaari, Reetta; Boyd, Sonja; Nieminen, Urpo; Arkkila, Perttu; Lundbom, Nina
2017-05-01
To study liver 31 P MRS, histology, transient elastography, and liver function tests in patients with virus C hepatitis (HCV) or autoimmune hepatitis (AIH) to test the hypothesis that 31 P MR metabolic profile of these diseases differ. 25 patients with HCV (n=12) or AIH (n=13) underwent proton decoupled 31 P MRS spectroscopy performed on a 3.0T MR imager. Intensities of phosphomonoesters (PME) of phosphoethanolamine (PE) and phosphocholine (PC), phosphodiesters (PDE) of glycerophosphoethanolamine (GPE) and glycerophosphocholine (GPC), and γ, α and β resonances of adenosine triphosphate (ATP), and nicotinamide adenine dinucleotide phosphate (NADPH) were determined. Liver stiffness was measured by transient elastography. Inflammation and fibrosis were staged according to METAVIR from biopsy samples. Activities of alanine transaminase (ALT), aspartate transaminase (AST), alkaline phosphatase (ALT) and thromboplastin time (TT) were determined from serum samples. PME had a stronger correlation with AST (z=1.73, p=0.04) and ALT (z=1.77, p=0.04) in HCV than in AIH patients. PME, PME/PDE, PE/GPE correlated positively and PDE negatively with inflammatory activity. PE, PC and PME correlated positively with liver function tests. 31 P-MRS suggests a more serious liver damage in HCV than in AIH with similar histopathological findings. 31 P-MRS is more sensitive in detecting inflammation than fibrosis in the liver. Copyright © 2017 Elsevier B.V. All rights reserved.
Crisi, Girolamo; Filice, Silvano; Michiara, Maria; Crafa, Pellegrino; Lana, Silvia
The objective of this study was to assess the effective performance of short echo time magnetic resonance spectroscopy (short TE MRS) for 2HG detection as biomarker of isocitrate dehydrogenase (IDH) status in all grade glioma (GL). A total of 82 GL patients were prospectively investigated by short TE MRS at 3.0 T as part of a multimodal magnetic resonance imaging study protocol. Spectral analysis was performed using linear combination model. Tumor specimens were diagnosed as IDH mutant or wild type according to the 2016 World Health Organization (WHO) classification of brain tumors. Spectra were analyzed for the presence of 2HG. The performance of short TE MRS was evaluated in terms of sensitivity, specificity, and positive and negative likelihood ratio on the overall sample and on GL WHO grades II and III and glioblastoma separately. The specificity and sensitivity estimated on the overall sample were 88% and 77%, respectively. In GL WHO grades II and III, 100% specificity and 75% sensitivity were estimated. We reiterate the feasibility to identify IDH status of brain GL using short TE MRS at 3.0 T. The method can correctly detect 2HG as expression of IDH mutation in WHO grades II and III GL with a 100% specificity but a 75% sensitivity. In the evaluation of glioblastoma, short TE MRS performs poorly having a 17% false positive rate.
MRS study of meningeal hemangiopericytoma and edema: a comparison with meningothelial meningioma.
Righi, Valeria; Tugnoli, Vitaliano; Mucci, Adele; Bacci, Antonella; Bonora, Sergio; Schenetti, Luisa
2012-10-01
Intracranial hemangiopericytomas (HPCs) are rare tumors and their radiological appearance resembles that of meningiomas, especially meningothelial meningiomas. To increase the knowledge on the biochemical composition of this type of tumor for better diagnosis and prognosis, we performed a molecular study using ex vivo high resolution magic angle spinning (HR-MAS) magnetic resonance spectroscopy (MRS) perfomed on HPC and peritumoral edematous tissues. Moreover, to help in the discrimination between HPC and meningothelial meningioma we compared the ex vivo HR-MAS spectra of samples from one patient with HPC and 5 patients affected by meningothelial meningioma. Magnetic resonance imaging (MRI), in vivo localized single voxel 1H-MRS was also performed on the same patients prior to surgery and the in vivo and ex vivo MRS spectra were compared. We observed the presence of OH-butyrate, together with glucose in HPC and a low amount of N-acetylaspartate in the edema, that may reflect neuronal alteration responsible for associated epilepsy. Many differences between HPC and meningothelial meningioma were identified. The relative ratios of myo-inositol, glucose and gluthatione with respect to glutamate are higher in HPC compared to meningioma; whereas the relative ratios of creatine, glutamine, alanine, glycine and choline-containing compounds with respect to glutamate are lower in HPC compared to meningioma. These data will be useful to improve the interpretation of in vivo MRS spectra resulting in a more accurate diagnosis of these rare tumors.
Baruth, Joshua M; Wall, Christopher A; Patterson, Marc C; Port, John D
2013-04-01
Proton magnetic resonance spectroscopy ((1) H-MRS) is a safe, noninvasive way of quantifying in vivo biochemical and metabolite concentration levels in individuals with Autism Spectrum Disorders (ASD). Findings to date suggest ASD is associated with widespread reduction in N-acetylaspartate (NAA), creatine plus phosphocreatine (Cr), choline-containing compounds (Cho), myo-inositol (mI), and glutamate plus glutamine plus gamma-Aminobutyric Acid (Glx); however, variable findings, and even substantial increases, are not uncommon depending on the study and/or region-of-interest. Widespread reduction of NAA, Cr, Cho, mI, and Glx in ASD likely reflects impaired neuronal function and/or metabolism related to abnormal neurodevelopmental processes. Future studies should attempt to relate (1) H-MRS findings to histological findings and control for variability in subject age and functioning level; this would assist in evaluating the relationship between (1) H-MRS metabolic levels and neuronal and glial cell densities, as well as neurodevelopmental process associated with ASD. Furthermore, more longitudinal (1) H-MRS studies are needed in both control and ASD subjects to attempt to standardize metabolite levels across different developmental periods in well-defined endophenotypes. This will provide for a standard rubric for which metabolic aberrations (as well as treatment responses) can be measured. With higher magnetic field strengths and spectral-editing techniques capable of quantifying less-concentrated metabolites, (1) H-MRS will continue to be an important tool in ASD research. © 2013 International Society for Autism Research, Wiley Periodicals, Inc.
Di Martino, Michele; Pacifico, Lucia; Bezzi, Mario; Di Miscio, Rossella; Sacconi, Beatrice; Chiesa, Claudio; Catalano, Carlo
2016-01-01
AIM To establish a threshold value for liver fat content between healthy children and those with non-alcoholic fatty liver disease (NAFLD) by using magnetic resonance imaging (MRI), with liver biopsy serving as a reference standard. METHODS The study was approved by the local ethics committee, and written informed consent was obtained from all participants and their legal guardians before the study began. Twenty-seven children with NAFLD underwent liver biopsy to assess the presence of nonalcoholic steatohepatitis. The assessment of liver fat fraction was performed using MRI, with a high field magnet and 2D gradient-echo and multiple-echo T1-weighted sequence with low flip angle and single-voxel point-resolved ¹H MR-Spectroscopy (¹H-MRS), corrected for T1 and T2* decays. Receiver operating characteristic curve analysis was used to determine the best cut-off value. Lin coefficient test was used to evaluate the correlation between histology, MRS and MRI-PDFF. A Mann-Whitney U-test and multivariate analysis were performed to analyze the continuous variables. RESULTS According to MRS, the threshold value between healthy children and those with NAFLD is 6%; using MRI-PDFF, a cut-off value of 3.5% is suggested. The Lin analysis revealed a good fit between the histology and MRS as well as MRI-PDFF. CONCLUSION MRS is an accurate and precise method for detecting NAFLD in children. PMID:27818597
Howells, Fleur M; Uhlmann, Anne; Temmingh, Henk; Sinclair, Heidi; Meintjes, Ernesta; Wilson, Don; Stein, Dan J
2014-03-01
Methamphetamine (MA) use has been shown to decrease n-acetyl-aspartate (NAA), a marker of neuronal integrity and viability, on (1)H magnetic resonance spectroscopy ((1)H-MRS). However, little work has compared (1)H-MRS in MA dependent individuals and MA dependent individuals with MA induced psychotic disorder (MAP). Twenty six participants with MA dependence (sixteen without psychosis, ten with psychosis - MAP) and nineteen healthy controls underwent 2D-chemical shift imaging (1)H-MRS, which included voxels in the anterior cingulate cortices (ACC), dorsolateral prefrontal cortices (DLPFC), and frontal white matter. We compared metabolite concentrations relative to phosphocreatine+creatine (PCr+Cr) for n-acetyl-aspartate (NAA), n-acetyl-aspartate+n-acetyl-aspartyl-glutamate (NAA+NAAG), glutamate (Glu), glutamate+glutamine (Glu+Gln), myo-inositol, and glycerophosphocholine+phosphocholine (GPC+PCh) across groups. The MA groups showed significantly decreased relative NAA metabolite concentrations for right ACC and right DLPFC, compared with control group. The MA dependent group only showed significantly decreased choline metabolites for right DLPFC, compared with control group. The MAP group's relative NAA metabolite concentrations were significantly correlated with age of initial use and duration of MA use, these correlates were not apparent in MA dependent group. MA use is associated with decreased neuronal integrity and viability, specifically in the right ACC and right DLPFC. MA dependence showed active neurodegeneration in the right DLPFC, this was not apparent in the MAP group and may be related to the use of antipsychotic medication in the MAP group. The effects of MA use in MAP suggest that age of initial use presents a mismatch of neuronal plasticity, in frontal white vs. gray matter and duration of use relates to decreased neuronal integrity and viability. Further study is warranted from this initial study of (1)H-MRS in MAP, in particular longitudinal assessment of these individuals both neurobiologically ((1)H-MRS) and clinically - to determine disease progression. Copyright © 2014 Elsevier B.V. All rights reserved.
MTR and In-vivo 1H-MRS studies on mouse brain with parkinson's disease
NASA Astrophysics Data System (ADS)
Yoon, Moon-Hyun; Kim, Hyeon-Jin; Chung, Jin-Yeung; Doo, Ah-Reum; Park, Hi-Joon; Kim, Seung-Nam; Choe, Bo-Young
2012-12-01
The aim of this study was to investigate whether the changes in the magnetization transfer ratio (MTR) histogram are related to specific characteristics of Parkinson's disease (PD) and to investigate whether the MTR histogram parameters are associated with neurochemical dysfunction by performing in vivo proton magnetic resonance spectroscopy (1H-MRS). MTR and in vivo 1H-MRS studies were performed on control mice (n = 10) and 1-methyl-1,2,3,6-tetrahydropyridine intoxicated mice (n = 10). All the MTR and in vivo 1H-MRS experiments were performed on a 9.4 T MRI/MRS system (Bruker Biospin, Germany) using a standard head coil. The protondensity fast spin echo (FSE) images and the T2-weighted spin echo (SE) images were acquired with no gap. Outer volume suppression (OVS), combined with the ultra-short echo-time stimulated echo acquisition mode (STEAM), was used for the localized in-vivo 1H-MRS. The quantitative analysis of metabolites was performed from the 1H spectra obtained in vivo on the striatum (ST) by using jMRUI (Lyon, France). The peak height of the MTR histograms in the PD model group was significantly lower than that in the control group (p < 0.05). The midbrain MTR values for volume were lower in the PD group than the control group(p < 0.05). The complex peak (Glx: glutamine+glutamate+ GABA)/creatine (Cr) ratio of the right ST in the PD group was significantly increased as compared to that of the control group. The present study revealed that the peak height of the MTR histogram was significantly decreased in the ST and substantia nigra, and a significant increase in the Gl x /Cr ratio was found in the ST of the PD group, as compared with that of the control group. These findings could reflect the early phase of neuronal dysfunction of neurotransmitters.
Winkelman, John W.; Buxton, Orfeu M.; Jensen, J. Eric; Benson, Kathleen L.; O'Connor, Shawn P.; Wang, Wei; Renshaw, Perry F.
2008-01-01
Study Objectives: Both basic and clinical data suggest a potential significant role for GABA in the etiology and maintenance of primary insomnia (PI). Proton magnetic resonance spectroscopy (1H-MRS) can non-invasively determine GABA levels in human brain. Our objective was to assess GABA levels in unmedicated individuals with PI, using 1H-MRS. Design and Setting: Matched-groups, cross-sectional study conducted at two university-based hospitals. Participants: Sixteen non-medicated individuals (8 women) with PI (mean age = 37.3 +/− 8.1) and 16 (7 women) well-screened normal sleepers (mean age = 37.6 +/− 4.5). Methods and Measurements: PI was established with an unstructured clinical interview, a Structured Clinical Interview for DSM-IV (SCID), sleep diary, actigraphy and polysomnography (PSG). 1H-MRS data were collected on a Varian 4 Tesla magnetic resonance imaging/spectroscopy scanner. Global brain GABA levels were averaged from samples in the basal ganglia, thalamus, and temporal, parietal, and occipital white-matter and cortex. Results: Average brain GABA levels were nearly 30% lower in patients with PI (.18 +/− .06) compared to controls (.25 +/− .11). GABA levels were negatively correlated with wake after sleep onset (WASO) on two independent PSGs (r = −0.71, p = 0.0024 and −0.70, p = 0.0048). Conclusions: Our preliminary finding of a global reduction in GABA in non-medicated individuals with PI is the first demonstration of a neurochemical difference in the brains of those with PI compared to normal sleeping controls. 1H-MRS is a valuable tool to assess GABA in vivo, and may provide a means to shed further light on the neurobiology of insomnia. Citation: Winkelman JW; Buxton OM; Jensen JE; Benson KL; O'Connor SP; Wang W; Renshaw PF. Reduced brain GABA in primary insomnia: preliminary data from 4T proton magnetic resonance spectroscopy (1H-MRS). SLEEP 2008;31(11):1499–1506. PMID:19014069
Lorenzo, José M; García Fontán, María C; Cachaldora, Aida; Franco, Inmaculada; Carballo, Javier
2010-04-01
Total aerobic mesophilic microflora (on SPC agar), lactic acid bacteria (on MRS agar) and lactobacilli (on Rogosa agar) were enumerated in samples from the surface and the interior of the pieces throughout the manufacture of six batches of lacón. Three of the batches were made without additives and three with additives (glucose (2 g/kg), sodium nitrite (E(250)) (125 mg/kg), sodium nitrate (E(251)) (175 mg/kg), sodium ascorbate (E(301)) (500 mg/kg), and sodium citrate (E(331)) (100 mg/kg)). The counts decreased throughout the manufacturing process, particularly after the salting stage. The use of additives did not affect the counts or the evolution of the microbial groups, except for the lactobacilli, which were present in higher numbers in the batches with additives. In four batches (two without and two with additives), from MRS agar and from Rogosa agar plates, 10 colonies were randomly taken from each sampling point of each batch (five from the surface sample and five from the interior sample) and from each culture medium; a total of 224 strains from MRS agar, and 176 strains from Rogosa agar that were identified by classical methods. The MRS agar displayed moderate selectivity for the isolation of lactic acid bacteria, and only 59% of the isolated strains belonged to this microbial group. Homofermentative and facultative heterofermentative lactobacilli (particularly Lactobacillus curvatus and Lactobacillus sakei) were the most abundant species isolated on this medium. The selectivity of the Rogosa agar for lactobacilli was extremely high. The species of lactobacilli isolated on this medium at different stages of manufacture of the four batches of lacón were consistent with those isolated from MRS agar. The use of additives in the lacón did not appreciably affect the kinds and proportions of species isolated on either MRS agar or Rogosa agar.
Zhang, Yang; Teng, Fei; Li, Suhang; Wan, Ling; Lin, Tingting
2017-10-27
The magnetic resonance sounding (MRS) technique is a non-invasive geophysical method that can provide unique insights into the hydrological properties of groundwater. The Cu coil sensor is the preferred choice for detecting the weak MRS signal because of its high sensitivity, low fabrication complexity and low cost. The tuned configuration was traditionally used for the MRS coil sensor design because of its high sensitivity and narrowband filtering. However, its narrow bandwidth may distort the MRS signals. To address this issue, a non-tuned design exhibiting a broad bandwidth has emerged recently, however, the sensitivity decreases as the bandwidth increases. Moreover, the effect of the MRS applications is often seriously influenced by power harmonic noises in the developed areas, especially low-frequency harmonics, resulting in saturation of the coil sensor, regardless of the tuned or non-tuned configuration. To solve the two aforementioned problems, we propose a matching network consisting of an LC broadband filter in parallel with a matching capacitor and provide a design for a coil sensor with a matching network (CSMN). The theoretical parameter calculations and the equivalent schematic of the CSMN with noise sources are investigated, and the sensitivity of the CSMN is evaluated by the Allan variance and the signal-to-noise ratio (SNR). Correspondingly, we constructed the CSMN with a 3 dB bandwidth, passband gain, normalized equivalent input noise and sensitivity (detection limit) of 1030 Hz, 4.6 dB, 1.78 nV/(Hz) 1/2 @ 2 kHz and 3 nV, respectively. Experimental tests in the laboratory show that the CSMN can not only improve the sensitivity, but also inhibit the signal distortion by suppressing power harmonic noises in the strong electromagnetic interference environment. Finally, a field experiment is performed with the CSMN to show a valid measurement of the signals of an MRS instrument system.
Zhang, Yang; Teng, Fei; Li, Suhang; Wan, Ling
2017-01-01
The magnetic resonance sounding (MRS) technique is a non-invasive geophysical method that can provide unique insights into the hydrological properties of groundwater. The Cu coil sensor is the preferred choice for detecting the weak MRS signal because of its high sensitivity, low fabrication complexity and low cost. The tuned configuration was traditionally used for the MRS coil sensor design because of its high sensitivity and narrowband filtering. However, its narrow bandwidth may distort the MRS signals. To address this issue, a non-tuned design exhibiting a broad bandwidth has emerged recently, however, the sensitivity decreases as the bandwidth increases. Moreover, the effect of the MRS applications is often seriously influenced by power harmonic noises in the developed areas, especially low-frequency harmonics, resulting in saturation of the coil sensor, regardless of the tuned or non-tuned configuration. To solve the two aforementioned problems, we propose a matching network consisting of an LC broadband filter in parallel with a matching capacitor and provide a design for a coil sensor with a matching network (CSMN). The theoretical parameter calculations and the equivalent schematic of the CSMN with noise sources are investigated, and the sensitivity of the CSMN is evaluated by the Allan variance and the signal-to-noise ratio (SNR). Correspondingly, we constructed the CSMN with a 3 dB bandwidth, passband gain, normalized equivalent input noise and sensitivity (detection limit) of 1030 Hz, 4.6 dB, 1.78 nV/(Hz)1/2 @ 2 kHz and 3 nV, respectively. Experimental tests in the laboratory show that the CSMN can not only improve the sensitivity, but also inhibit the signal distortion by suppressing power harmonic noises in the strong electromagnetic interference environment. Finally, a field experiment is performed with the CSMN to show a valid measurement of the signals of an MRS instrument system. PMID:29076986
Belkić, Dževad; Belkić, Karen
2015-06-01
Magnetic resonance (MR)-based modalities aid breast cancer detection without exposure to ionizing radiation. Magnetic resonance imaging is very sensitive but costly and insufficiently specific. Molecular imaging through magnetic resonance spectroscopy (MRS) can provide information about key metabolites. Here, the measured/encoded time signals cannot be interpreted directly, necessitating mathematics for mapping to the more manageable frequency domain. Conventional applications of MRS are hampered by data analysis via the fast Fourier transform (FFT) and postprocessing by fitting techniques. Most in vivo MRS studies on breast cancer rely upon estimations of total choline (tCHO). These have yielded only incremental improvements in diagnostic accuracy. In vitro studies reveal richer metabolic information for identifying breast cancer, particularly in closely overlapping components of tCHO. Among these are phosphocholine (PC), a marker of malignant transformation of the breast. The FFT cannot assess these congested spectral components. This can be done by the fast Padé transform (FPT), a high-resolution, quantification-equipped method, which we presently apply to noisy MRS time signals consistent with those encoded in breast cancer. The FPT unequivocally and robustly extracted the concentrations of all physical metabolites, including PC. In sharp contrast, the FFT produced a rough envelope spectrum with a few distorted peaks and key metabolites absent altogether. As such, the FFT has poor resolution for these typical MRS time signals from breast cancer. Hence, based on Fourier-estimated envelope spectra, tCHO estimates are unreliable. Using even truncated time signals, the FPT clearly distinguishes noise from true metabolites whose concentrations are accurately extracted. The high resolution of the FPT translates directly into shortened examination time of the patient. These capabilities strongly suggest that by applying the FPT to time signals encoded in vivo from the breast, MRS will, at last, fulfill its potential to become a clinically reliable, cost-effective method for breast cancer detection, including screening/surveillance. © The Author(s) 2014.
Schmidt, Tony M; Wang, Zhiyue J; Keller, Sarah; Heinemann, Axel; Acar, Suzan; Graessner, Joachim; Schoennagel, Bjoern P; Adam, Gerhard; Fischer, Roland; Yamamura, Jin
2014-09-01
Phosphor magnetic resonance spectroscopy ((31)P MRS) is an established method for metabolic examinations of resting and exercising skeletal muscle. So far, there are few MRS investigations of human corpses. The aim of this study was to investigate the temporal postmortem pattern of phosphor metabolites in the adductor magnus muscle and to check the value of MRS as a forensic tool, especially for the determination of the time of death. Eight corpses, died of natural cause, were examined (5 males, 3 females; age: 73±7 y, weight 65.8±15.9 kg). A control group of 3 subjects (2 males, 1 female, mean age: 51±24 y, range: 24-69 y, mean body weight: 84.0±16.5 kg) was examined at a single time point as well. (31)P MRS was performed on a 1.5 T MRI (TR 700 ms, TE 0.35 ms, averages 256, flip angle 90°). A standard (31)P/(1)H heart/liver coil was employed (receiver coil diameter 12 cm). The (31)P MRS scans were repeated in intervals of 1 h over a period from 4.5 to 24 h postmortem (p.m.). The core temperature was rectally measured throughout the MRI examination. The mean core temperature decreased from 36.0°C to 25.7°C. In vivo and ex vivo spectra showed characteristic differences, especially the PCr metabolite was no longer detectable after 10 h p.m. The α-ATP/Pi ratio decreased with time from 0.445 to 0.032 over 24 h p.m. There is a characteristic postmortem time pattern of the phosphor metabolites. Especially the acquired α-ATP/Pi ratio could be described by a significant exponential time course (r(2)=0.92, p<0.001). (31)P MRS might be added to the postmortem imaging methods. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Nakajima, Madoka; Miyajima, Masakazu; Ogino, Ikuko; Akiba, Chihiro; Kawamura, Kaito; Kurosawa, Michiko; Kuriyama, Nagato; Watanabe, Yoshiyuki; Fukushima, Wakaba; Mori, Etsuro; Kato, Takeo; Sugano, Hidenori; Karagiozov, Kostadin; Arai, Hajime
2018-01-01
Background and Purpose: This study aimed to investigate the efficacy of cerebrospinal fluid shunt intervention for idiopathic normal pressure hydrocephalus (iNPH) using data from a nationwide epidemiological survey in Japan. Methods: We conducted a cross-sectional study using data from a nationwide epidemiological survey performed in Japan. Propensity score matching was used to select 874 patients from 1,423 patients aged ≥60 years, who were diagnosed with iNPH based on clinical guidelines following a hospital visit in 2012. Patients who experienced an improvement of at least 1 modified Rankin Scale (mRS) grade after the intervention were classified as "improved," while the remaining patients were classified as "non-improved." In the shunt intervention ( n = 437) and non-shunt intervention ( n = 437) groups, the differences in mRS grade improvement were analyzed using the Mann-Whitney U -test. Finally, we examined subjects in the shunt intervention group ( n = 974) to compare the outcomes and complications of ventriculoperitoneal (VP) shunt (n = 417) with lumboperitoneal (LP) shunt ( n = 540). Results: We examined subjects with iNPH to compare the non-shunt intervention group to the shunt intervention group following adjustment for age and mRS grade at baseline by propensity score matching (0.31-0.901). The mRS grade (mean [SD]) was found to improve with non-shunt intervention (2.46 [0.88]) and shunt intervention (1.93 [0.93]) ( p < 0.001) in iNPH patients. The mRS outcome score and complications comparison between the VP and LP shunt groups did not show significant difference. Conclusions: In this study, analysis of the efficacy of shunts for possible iNPH conducted in Japan indicated a significant improvement in the mRS grade between baseline and outcome within 1 year, regardless of the surgical technique, and shunt intervention was found to be effective.
Bakermans, Adrianus J; Bazil, Jason N; Nederveen, Aart J; Strijkers, Gustav J; Boekholdt, S Matthijs; Beard, Daniel A; Jeneson, Jeroen A L
2017-01-01
Phosphorus-31 magnetic resonance spectroscopy ( 31 P-MRS) is a unique non-invasive imaging modality for probing in vivo high-energy phosphate metabolism in the human heart. We investigated whether current 31 P-MRS methodology would allow for clinical applications to detect exercise-induced changes in (patho-)physiological myocardial energy metabolism. Hereto, measurement variability and repeatability of three commonly used localized 31 P-MRS methods [3D image-selected in vivo spectroscopy (ISIS) and 1D ISIS with 1D chemical shift imaging (CSI) oriented either perpendicular or parallel to the surface coil] to quantify the myocardial phosphocreatine (PCr) to adenosine triphosphate (ATP) ratio in healthy humans ( n = 8) at rest were determined on a clinical 3 Tesla MR system. Numerical simulations of myocardial energy homeostasis in response to increased cardiac work rates were performed using a biophysical model of myocardial oxidative metabolism. Hypertrophic cardiomyopathy was modeled by either inefficient sarcomere ATP utilization or decreased mitochondrial ATP synthesis. The effect of creatine depletion on myocardial energy homeostasis was explored for both conditions. The mean in vivo myocardial PCr/ATP ratio measured with 3D ISIS was 1.57 ± 0.17 with a large repeatability coefficient of 40.4%. For 1D CSI in a 1D ISIS-selected slice perpendicular to the surface coil, the PCr/ATP ratio was 2.78 ± 0.50 (repeatability 42.5%). With 1D CSI in a 1D ISIS-selected slice parallel to the surface coil, the PCr/ATP ratio was 1.70 ± 0.56 (repeatability 43.7%). The model predicted a PCr/ATP ratio reduction of only 10% at the maximal cardiac work rate in normal myocardium. Hypertrophic cardiomyopathy led to lower PCr/ATP ratios for high cardiac work rates, which was exacerbated by creatine depletion. Simulations illustrated that when conducting cardiac 31 P-MRS exercise stress testing with large measurement error margins, results obtained under pathophysiologic conditions may still lie well within the 95% confidence interval of normal myocardial PCr/ATP dynamics. Current measurement precision of localized 31 P-MRS for quantification of the myocardial PCr/ATP ratio precludes the detection of the changes predicted by computational modeling. This hampers clinical employment of 31 P-MRS for diagnostic testing and risk stratification, and warrants developments in cardiac 31 P-MRS exercise stress testing methodology.
Baggio, Jussara A O; Santos-Pontelli, Taiza E G; Cougo-Pinto, Pedro T; Camilo, Millene; Silva, Nathalia F; Antunes, Paula; Machado, Laura; Leite, João P; Pontes-Neto, Octavio M
2014-01-01
The modified Rankin Scale (mRS) is a commonly used scale to assess the functional outcome after stroke. Several studies on mRS showed good reliability, feasibility, and interrater agreement of this scale using a face-to-face assessment. However, telephone assessment is a more time-efficient way to obtain an mRS grade than a face-to-face interview. The aim of this study was to validate the telephone assessment of mRS among the Portuguese using a structured interview in a sample of Brazilian stroke patients. We evaluated 50 stroke outpatients twice. The first interview was face-to-face and the second was made by telephone and the time between the two assessments ranged between 7 and 14 days. Four certified raters evaluated the patients using a structured interview based on a questionnaire previously published in the literature. Raters were blinded for the Rankin score given by the other rater. For both assessments, the rater could also interview a caregiver if necessary. The patients' mean age was 62.8 ± 14.7, mean number of years of study 5.2 ± 3.4, 52% were males, 55.2% of patients needed a caregiver's help to answer the questions. The majority of caregivers were female (85%), mean age 49.1 ± 15, and mean number of years of study 8.3 ± 3.4. Perfect agreement between the telephone and face-to-face assessments was obtained for 27 (54%) patients, corresponding to an unweighted Kappa of 0.44 (95% CI 0.27-0.61) and a weighted Kappa of 0.89. The median of telephone assessment mRS was 3.5 (interquartile range = 2-4) and of face-to-face assessment was 4 (interquartile range = 2-5). There was no difference between the two assessments (Wilcoxon test, p = 0.35). Despite the low education level of our sample, the telephone assessment of functional impairment of stroke patients using a translated and culturally adapted Brazilian Portuguese version of the mRS showed good validity and reliability. Therefore, the telephone assessment of mRS can be used in clinical practice and scientific studies in Brazil. © 2014 S. Karger AG, Basel.
Bakermans, Adrianus J.; Bazil, Jason N.; Nederveen, Aart J.; Strijkers, Gustav J.; Boekholdt, S. Matthijs; Beard, Daniel A.; Jeneson, Jeroen A. L.
2017-01-01
Phosphorus-31 magnetic resonance spectroscopy (31P-MRS) is a unique non-invasive imaging modality for probing in vivo high-energy phosphate metabolism in the human heart. We investigated whether current 31P-MRS methodology would allow for clinical applications to detect exercise-induced changes in (patho-)physiological myocardial energy metabolism. Hereto, measurement variability and repeatability of three commonly used localized 31P-MRS methods [3D image-selected in vivo spectroscopy (ISIS) and 1D ISIS with 1D chemical shift imaging (CSI) oriented either perpendicular or parallel to the surface coil] to quantify the myocardial phosphocreatine (PCr) to adenosine triphosphate (ATP) ratio in healthy humans (n = 8) at rest were determined on a clinical 3 Tesla MR system. Numerical simulations of myocardial energy homeostasis in response to increased cardiac work rates were performed using a biophysical model of myocardial oxidative metabolism. Hypertrophic cardiomyopathy was modeled by either inefficient sarcomere ATP utilization or decreased mitochondrial ATP synthesis. The effect of creatine depletion on myocardial energy homeostasis was explored for both conditions. The mean in vivo myocardial PCr/ATP ratio measured with 3D ISIS was 1.57 ± 0.17 with a large repeatability coefficient of 40.4%. For 1D CSI in a 1D ISIS-selected slice perpendicular to the surface coil, the PCr/ATP ratio was 2.78 ± 0.50 (repeatability 42.5%). With 1D CSI in a 1D ISIS-selected slice parallel to the surface coil, the PCr/ATP ratio was 1.70 ± 0.56 (repeatability 43.7%). The model predicted a PCr/ATP ratio reduction of only 10% at the maximal cardiac work rate in normal myocardium. Hypertrophic cardiomyopathy led to lower PCr/ATP ratios for high cardiac work rates, which was exacerbated by creatine depletion. Simulations illustrated that when conducting cardiac 31P-MRS exercise stress testing with large measurement error margins, results obtained under pathophysiologic conditions may still lie well within the 95% confidence interval of normal myocardial PCr/ATP dynamics. Current measurement precision of localized 31P-MRS for quantification of the myocardial PCr/ATP ratio precludes the detection of the changes predicted by computational modeling. This hampers clinical employment of 31P-MRS for diagnostic testing and risk stratification, and warrants developments in cardiac 31P-MRS exercise stress testing methodology. PMID:29230178
Reynolds, Joshua C.; Grunau, Brian E.; Rittenberger, Jon C.; Sawyer, Kelly N.; Kurz, Michael C.; Callaway, Clifton W.
2016-01-01
Background Little evidence guides the appropriate duration of resuscitation in out-of-hospital cardiac arrest (OHCA), and case features justifying longer or shorter durations are ill-defined. We estimated the impact of resuscitation duration on the probability of favorable functional outcome in OHCA using a large, multi-center cohort. Methods Secondary analysis of a North American, single blind, multi-center, cluster-randomized clinical trial (ROC-PRIMED) of consecutive adults with non-traumatic, EMS-treated, OHCA. Primary exposure was duration of resuscitation in minutes (onset of professional resuscitation to return of spontaneous circulation [ROSC] or termination of resuscitation). Primary outcome was survival to hospital discharge with favorable outcome (modified Rankin scale [mRS] 0-3). Subjects were additionally classified as survival with unfavorable outcome (mRS 4-5), ROSC without survival (mRS 6), or without ROSC. Subject accrual was plotted as a function of resuscitation duration, and the dynamic probability of favorable outcome at discharge was estimated for the whole cohort and subgroups. Adjusted logistic regression models tested the association between resuscitation duration and survival with favorable outcome. Results The primary cohort included 11,368 subjects (median age 69 years [IQR: 56-81 years]; 7,121 men [62.6%]). Of these, 4,023 (35.4%) achieved ROSC, 1,232 (10.8%) survived to hospital discharge, and 905 (8.0%) had mRS 0-3 at discharge. Distribution of CPR duration differed by outcome (p<0.00001). For CPR duration up to 37.0 minutes (95%CI 34.9-40.9 minutes), 99% with eventual mRS 0-3 at discharge achieved ROSC. Dynamic probability of mRS 0-3 at discharge declined over elapsed resuscitation duration, but subjects with initial shockable cardiac rhythm, witnessed cardiac arrest, and bystander CPR were more likely to survive with favorable outcome after prolonged efforts (30-40 minutes). Adjusting for prehospital (OR 0.93; 95%CI 0.92-0.95) and inpatient (OR 0.97; 95%CI 0.95-0.99) covariates, resuscitation duration was associated with survival to discharge with mRS 0-3. Conclusions Shorter resuscitation duration was associated with likelihood of favorable outcome at hospital discharge. Subjects with favorable case features were more likely to survive prolonged resuscitation up to 47 minutes. PMID:27760796
Bakermans, Adrianus J; Abdurrachim, Desiree; van Nierop, Bastiaan J; Koeman, Anneke; van der Kroon, Inge; Baartscheer, Antonius; Schumacher, Cees A; Strijkers, Gustav J; Houten, Sander M; Zuurbier, Coert J; Nicolay, Klaas; Prompers, Jeanine J
2015-10-01
(31)P MRS provides a unique non-invasive window into myocardial energy homeostasis. Mouse models of cardiac disease are widely used in preclinical studies, but the application of (31)P MRS in the in vivo mouse heart has been limited. The small-sized, fast-beating mouse heart imposes challenges regarding localized signal acquisition devoid of contamination with signal originating from surrounding tissues. Here, we report the implementation and validation of three-dimensional image-selected in vivo spectroscopy (3D ISIS) for localized (31)P MRS of the in vivo mouse heart at 9.4 T. Cardiac (31)P MR spectra were acquired in vivo in healthy mice (n = 9) and in transverse aortic constricted (TAC) mice (n = 8) using respiratory-gated, cardiac-triggered 3D ISIS. Localization and potential signal contamination were assessed with (31)P MRS experiments in the anterior myocardial wall, liver, skeletal muscle and blood. For healthy hearts, results were validated against ex vivo biochemical assays. Effects of isoflurane anesthesia were assessed by measuring in vivo hemodynamics and blood gases. The myocardial energy status, assessed via the phosphocreatine (PCr) to adenosine 5'-triphosphate (ATP) ratio, was approximately 25% lower in TAC mice compared with controls (0.76 ± 0.13 versus 1.00 ± 0.15; P < 0.01). Localization with one-dimensional (1D) ISIS resulted in two-fold higher PCr/ATP ratios than measured with 3D ISIS, because of the high PCr levels of chest skeletal muscle that contaminate the 1D ISIS measurements. Ex vivo determinations of the myocardial PCr/ATP ratio (0.94 ± 0.24; n = 8) confirmed the in vivo observations in control mice. Heart rate (497 ± 76 beats/min), mean arterial pressure (90 ± 3.3 mmHg) and blood oxygen saturation (96.2 ± 0.6%) during the experimental conditions of in vivo (31)P MRS were within the normal physiological range. Our results show that respiratory-gated, cardiac-triggered 3D ISIS allows for non-invasive assessments of in vivo mouse myocardial energy homeostasis with (31)P MRS under physiological conditions. Copyright © 2015 John Wiley & Sons, Ltd.
2012-01-01
Background MicroRNAs (miRNAs) are one of the functional non-coding small RNAs involved in the epigenetic control of the plant genome. Although plants contain both evolutionary conserved miRNAs and species-specific miRNAs within their genomes, computational methods often only identify evolutionary conserved miRNAs. The recent sequencing of the Brassica rapa genome enables us to identify miRNAs and their putative target genes. In this study, we sought to provide a more comprehensive prediction of B. rapa miRNAs based on high throughput small RNA deep sequencing. Results We sequenced small RNAs from five types of tissue: seedlings, roots, petioles, leaves, and flowers. By analyzing 2.75 million unique reads that mapped to the B. rapa genome, we identified 216 novel and 196 conserved miRNAs that were predicted to target approximately 20% of the genome’s protein coding genes. Quantitative analysis of miRNAs from the five types of tissue revealed that novel miRNAs were expressed in diverse tissues but their expression levels were lower than those of the conserved miRNAs. Comparative analysis of the miRNAs between the B. rapa and Arabidopsis thaliana genomes demonstrated that redundant copies of conserved miRNAs in the B. rapa genome may have been deleted after whole genome triplication. Novel miRNA members seemed to have spontaneously arisen from the B. rapa and A. thaliana genomes, suggesting the species-specific expansion of miRNAs. We have made this data publicly available in a miRNA database of B. rapa called BraMRs. The database allows the user to retrieve miRNA sequences, their expression profiles, and a description of their target genes from the five tissue types investigated here. Conclusions This is the first report to identify novel miRNAs from Brassica crops using genome-wide high throughput techniques. The combination of computational methods and small RNA deep sequencing provides robust predictions of miRNAs in the genome. The finding of numerous novel miRNAs, many with few target genes and low expression levels, suggests the rapid evolution of miRNA genes. The development of a miRNA database, BraMRs, enables us to integrate miRNA identification, target prediction, and functional annotation of target genes. BraMRs will represent a valuable public resource with which to study the epigenetic control of B. rapa and other closely related Brassica species. The database is available at the following link: http://bramrs.rna.kr [1]. PMID:23163954
NASA Technical Reports Server (NTRS)
2004-01-01
KENNEDY SPACE CENTER, FLA. -- Neil Yorio, a Dynamac scientist (right), explains the function of the KSC Space Life Sciences (SLS) Lab to a prestigious tour group. From left are NASA Administrator Sean OKeefe and his wife, Laura; Florida Gov. Jeb Bush; Bernadette Kennedy, wife of the Center Director (CD); Columba Bush, wife of the governor; behind Mrs. Bush, former astronaut Winston Scott; and third from right, CD Jim Kennedy. The new lab is a state-of-the-art facility built for ISS biotechnology research. It was developed as a partnership between NASA-KSC and the State of Florida. The tour followed the launching ceremony at the KSC Visitor Complex for the new Florida quarter issued by the U.S. Mint. The ceremony was emceed by Kennedy and included remarks by OKeefe, Bush, U.S. Mint Director Henrietta Holsman Fore and Deputy Secretary of the Treasury Samuel W. Bodman.
Small serine recombination systems ParA-MRS and CinH-RS2 perform precise excision of plastid DNA
USDA-ARS?s Scientific Manuscript database
Selectable marker genes (SMGs) are necessary for selection of transgenic plants. However, once stable transformants have been identified, the marker gene is no longer needed. In this study, we demonstrate the use of the small serine recombination systems, ParA-MRS and CinH-RS2, to precisely excise ...
ERIC Educational Resources Information Center
Beck, Bernard
2017-01-01
Four recent movies, "Hidden Figures," "The Zookeeper's Wife," "Their Finest," and "Colossal" exemplify a new cultural version of the movie heroine. This version combines feminism with commitment to solving an overwhelming problem. These heroines, thus, display the character virtues of Wonder Woman and Mrs.…
Shock, Chaos, and Change: An Elementary School Turned Upside Down
ERIC Educational Resources Information Center
Cantú, Yvette; Rocha, Patricia; Martinez, Melissa A.
2016-01-01
The following case is inspired by real-life events that the authors experienced while working in the K-12 public school system. This case describes the experiences of Mrs. Hodge, a seasoned assistant principal who was unexpectedly assigned to be principal of her elementary school. The case follows Mrs. Hodge through her first 3 years as the…
To Form a Favorable Idea of Chemistry
ERIC Educational Resources Information Center
Heikkinen, Henry W.
2010-01-01
"To confess the truth, Mrs. B., I am not disposed to form a very favorable idea of chemistry, nor do I expect to derive much entertainment from it." That 200-year-old statement by Caroline to Mrs. Bryan, her teacher, appeared on the first page of Jane Marcet's pioneering secondary school textbook, "Conversations on Chemistry". It was published 17…
Use of the Titles Ms., Miss or Mrs.: Does It Make a Difference?
ERIC Educational Resources Information Center
Conner, Jane; And Others
1986-01-01
People in a shopping mall were asked to read a paragraph about an achieving woman given the title Miss, Mrs., Ms., or not given a title. Readers of Ms titled paragraph rated her less honest. No effects obtained for other rating dimensions. Results may indicate public acceptance of Ms title. (MCK)
Kim, Hyeonjin; Kim, Sungjin; Lee, Hyeong Hun; Heo, Hwon
2016-01-01
The diagnostic and prognostic potential of an onco-metabolite, 2-hydroxyglutarate (2HG) as a proton magnetic resonance spectroscopy (1H-MRS) detectable biomarker of the isocitrate dehydrogenase (IDH)-mutated (IDH-MT) gliomas has drawn attention of neuroradiologists recently. However, due to severe spectral overlap with background signals, quantification of 2HG can be very challenging. In this technical review for neuroradiologists, first, the biochemistry of 2HG and its significance in the diagnosis of IDH-MT gliomas are summarized. Secondly, various 1H-MRS methods used in the previous studies are outlined. Finally, wereview previous in vivo studies, and discuss the current status of 1H-MRS in the diagnosis of IDH-MT gliomas.
View of Mission Control Center during the Apollo 13 oxygen cell failure
NASA Technical Reports Server (NTRS)
1970-01-01
Mrs. Mary Haise receives an explanation of the revised flight plan of the Apollo 13 mission from Astronaut Gerald P. Carr in the Viewing Room of Mission Control Center, bldg 30, Manned Spacecraft Center (MSC). Her husband, Astronaut Fred W. Haise Jr., was joining the fellow crew members in making corrections in their spacecraft following discovery of an oxygen cell failure several hours earlier (34900); Dr. Charles A. Berry, Director of Medical Research and Operations Directorate at MSC, converses with Mrs. Marilyn Lovell in the Viewing Room of Mission Control Center. Mrs. Lovell's husband, Astronaut James A. Lovell Jr., was busily making corrections inside the spacecraft following discovery of an oxygen cell failure several hours earlier (34901).
Weiss, Sonja; Kadlec, Kristina; Fessler, Andrea T; Schwarz, Stefan
2013-12-27
The aim of this study was to isolate and characterize methicillin-resistant staphylococci (MRS) in a small animal clinic and to investigate their distribution and possible transmission. Swabs (n=72) were taken from hospitalized pets, the environment and employees of a small animal clinic and screened for the presence of MRS. The staphylococcal species was confirmed biochemically or by 16S rDNA sequencing. Susceptibility to antimicrobial agents was tested by broth dilution. The presence of mecA and other resistance genes was confirmed by PCR. Molecular typing of the isolates followed standard procedures. In total, 34 MRS belonging to the four species Staphylococcus aureus (n=5), Staphylococcus epidermidis (n=21), Staphylococcus haemolyticus (n=6) or Staphylococcus pettenkoferi (n=2) were isolated. All isolates were multidrug-resistant with resistance to at least three classes of antimicrobial agents. Among the five methicillin-resistant S. aureus (MRSA) isolates, four belonged to the clonal complex CC398; two of them were isolated from cats, the remaining two from pet cages. Overall, the MRS isolates differed in their characteristics, except for one S. epidermidis clone (n=9) isolated from hospitalized cats without clinical staphylococcal infections, pet cages, the clinic environment as well as from a healthy employee. This MRSE clone was resistant to 10 classes of antimicrobial agents, including aminocyclitols, β-lactams, fluoroquinolones, lincosamides, macrolides, phenicols, pleuromutilins, sulfonamides, tetracyclines and trimethoprim. These findings suggest a possible transmission of specific MRS isolates between animal patients, employees and the clinic environment. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Belkić, Dževad; Belkić, Karen
2018-01-01
This paper on molecular imaging emphasizes improving specificity of magnetic resonance spectroscopy (MRS) for early cancer diagnostics by high-resolution data analysis. Sensitivity of magnetic resonance imaging (MRI) is excellent, but specificity is insufficient. Specificity is improved with MRS by going beyond morphology to assess the biochemical content of tissue. This is contingent upon accurate data quantification of diagnostically relevant biomolecules. Quantification is spectral analysis which reconstructs chemical shifts, amplitudes and relaxation times of metabolites. Chemical shifts inform on electronic shielding of resonating nuclei bound to different molecular compounds. Oscillation amplitudes in time signals retrieve the abundance of MR sensitive nuclei whose number is proportional to metabolite concentrations. Transverse relaxation times, the reciprocal of decay probabilities of resonances, arise from spin-spin coupling and reflect local field inhomogeneities. In MRS single voxels are used. For volumetric coverage, multi-voxels are employed within a hybrid of MRS and MRI called magnetic resonance spectroscopic imaging (MRSI). Common to MRS and MRSI is encoding of time signals and subsequent spectral analysis. Encoded data do not provide direct clinical information. Spectral analysis of time signals can yield the quantitative information, of which metabolite concentrations are the most clinically important. This information is equivocal with standard data analysis through the non-parametric, low-resolution fast Fourier transform and post-processing via fitting. By applying the fast Padé transform (FPT) with high-resolution, noise suppression and exact quantification via quantum mechanical signal processing, advances are made, presented herein, focusing on four areas of critical public health importance: brain, prostate, breast and ovarian cancers.
Potential of MR spectroscopy for assessment of glioma grading.
Bulik, Martin; Jancalek, Radim; Vanicek, Jiri; Skoch, Antonin; Mechl, Marek
2013-02-01
Magnetic resonance spectroscopy (MRS) is an imaging diagnostic method based that allows non-invasive measurement of metabolites in tissues. There are a number of metabolites that can be identified by standard brain proton MRS but only a few of them has a clinical significance in diagnosis of gliomas including N-acetylaspartate, choline, creatine, myo-inositol, lactate, and lipids. In this review, we describe potential of MRS for grading of gliomas. Low-grade gliomas are generally characterized by a relatively high concentration of N-acetylaspartate, low level of choline and absence of lactate and lipids. The increase in creatine concentration indicates low-grade gliomas with earlier progression and malignant transformation. Progression in grade of a glioma is reflected in the progressive decrease in the N-acetylaspartate and myo-inositol levels on the one hand and elevation in choline level up to grade III on the other. Malignant transformation of the glial tumors is also accompanied by the presence of lactate and lipids in MR spectra of grade III but mainly grade IV gliomas. It follows that MRS is a helpful method for detection of glioma regions with aggressive growth or upgrading due to favorable correlation of the choline and N-acetylaspartate levels with histopathological proliferation index Ki-67. Thus, magnetic resonance spectroscopy is also a suitable method for the targeting of brain biopsies. Gliomas of each grade have some specific MRS features that can be used for improvement of the diagnostic value of conventional magnetic resonance imaging in non-invasive assessment of glioma grade. Crown Copyright © 2012. Published by Elsevier B.V. All rights reserved.
Landim, Ricardo C.G.; Edden, Richard A.E.; Foerster, Bernd; Li, Li Min; Covolan, Roberto J.M.; Castellano, Gabriela
2017-01-01
N-acetyl-aspartate (NAA) is responsible for the majority of the most prominent peak in 1H-MR spectra, and has been used as diagnostic marker for several pathologies. However, ~10% of this peak can be attributed to N-acetyl-aspartyl-glutamate (NAAG), a neuropeptide whose release may be triggered by intense neuronal activation. Separate measurement of NAA and NAAG using MRS is difficult due to large superposition of their spectra. Specifically, in functional MRS (fMRS) experiments, most work has evaluated the sum NAA + NAAG, which does not appear to change during experiments. The aim of this work was to design and perform an fMRS experiment using visual stimulation and a spectral editing sequence, MEGA-PRESS, to further evaluate the individual dynamics of NAA and NAAG during brain activation. The functional paradigm used consisted of three blocks, starting with a rest (baseline) block of 320 s, followed by a stimulus block (640 s) and a rest block (640 s). Twenty healthy subjects participated in this study. On average, subjects followed a pattern of NAA decrease and NAAG increase during stimulation, with a tendency to return to basal levels at the end of the paradigm, with a peak NAA decrease of −(21 ± 19)% and a peak NAAG increase of (64 ± 62)% (Wilcoxon test, p < 0.05). These results may relate to: 1) the only known NAAG synthesis pathway is from NAA and glutamate; 2) a relationship between NAAG and the BOLD response. PMID:26656908
Landim, Ricardo C G; Edden, Richard A E; Foerster, Bernd; Li, Li Min; Covolan, Roberto J M; Castellano, Gabriela
2016-04-01
N-acetyl-aspartate (NAA) is responsible for the majority of the most prominent peak in (1)H-MR spectra, and has been used as diagnostic marker for several pathologies. However, ~10% of this peak can be attributed to N-acetyl-aspartyl-glutamate (NAAG), a neuropeptide whose release may be triggered by intense neuronal activation. Separate measurement of NAA and NAAG using MRS is difficult due to large superposition of their spectra. Specifically, in functional MRS (fMRS) experiments, most work has evaluated the sum NAA+NAAG, which does not appear to change during experiments. The aim of this work was to design and perform an fMRS experiment using visual stimulation and a spectral editing sequence, MEGA-PRESS, to further evaluate the individual dynamics of NAA and NAAG during brain activation. The functional paradigm used consisted of three blocks, starting with a rest (baseline) block of 320 s, followed by a stimulus block (640 s) and a rest block (640 s). Twenty healthy subjects participated in this study. On average, subjects followed a pattern of NAA decrease and NAAG increase during stimulation, with a tendency to return to basal levels at the end of the paradigm, with a peak NAA decrease of -(21±19)% and a peak NAAG increase of (64±62)% (Wilcoxon test, p<0.05). These results may relate to: 1) the only known NAAG synthesis pathway is from NAA and glutamate; 2) a relationship between NAAG and the BOLD response. Copyright © 2015 Elsevier Inc. All rights reserved.
Serial 1H-MRS in GM2 gangliosidoses.
Assadi, Mitra; Baseman, Susan; Janson, Christopher; Wang, Dah-Jyuu; Bilaniuk, Larissa; Leone, Paola
2008-03-01
GM2 gangliosidoses are a group of neuronal storage disorders caused by deficiency in the lysosomal enzyme hexosaminidase A. Clinically, the disease is marked by a relentless encephalopathy. Proton magnetic resonance spectroscopy (1H-MRS) provides in-vivo measurement of various brain metabolites including N-acetyl aspartate+N-acetyl aspartate glutamate (NAA), myo-inositol (mI), choline (Cho) and creatine (Cr). The NAA represents neuronal integrity while elevation in the mI reflects abnormal inflammation and gliosis in the brain tissue. An elevation in the Cho levels suggest cell membrane breakdown and demyelination. We report the clinical and laboratory data in two patients with GM2 gangliosidoses. Serial 1H-MRS evaluations were performed to drive metabolite ratios of NAA/Cr, mI/Cr and Cho/Cr. We acquired the data from four regions of interest (ROI) according to a standard protocol. The results documented a progressive elevation in mI/Cr in all four ROI in patient one and only one ROI (occipital gray matter) in patient 2. We also documented a decline in the NAA/Cr ratios in both cases in most ROI. These results were compared to six age-matched controls and confirmed statistically significant elevation in the mI in our cases. In conclusion, 1H-MRS alterations were suggestive of neuronal loss and inflammation in these patients. 1H-MRS may be a valuable tool in monitoring the disease progress and response to therapy in GM2 gangliosidoses. Elevation in the mI may prove to be more sensitive than the other metabolite alterations.
Almeida, Gilberto S; Bawn, Carlo M; Galler, Martin; Wilson, Ian; Thomas, Huw D; Kyle, Suzanne; Curtin, Nicola J; Newell, David R; Maxwell, Ross J
2017-09-01
Poly(adenosine diphosphate ribose) polymerases (PARPs) are multifunctional proteins which play a role in many cellular processes. Namely, PARP1 and PARP2 have been shown to be involved in DNA repair, and therefore are valid targets in cancer treatment with PARP inhibitors, such as rucaparib, currently in clinical trials. Proton magnetic resonance spectroscopy ( 1 H-MRS) was used to study the impact of rucaparib in vitro and ex vivo in liver tissue from mice, via quantitative analysis of nicotinamide adenosine diphosphate (NAD + ) spectra, to assess the potential of MRS as a biomarker of the PARP inhibitor response. SW620 (colorectal) and A2780 (ovarian) cancer cell lines, and PARP1 wild-type (WT) and PARP1 knock-out (KO) mice, were treated with rucaparib, temozolomide (methylating agent) or a combination of both drugs. 1 H-MRS spectra were obtained from perchloric acid extracts of tumour cells and mouse liver. Both cell lines showed an increase in NAD + levels following PARP inhibitor treatment in comparison with temozolomide treatment. Liver extracts from PARP1 WT mice showed a significant increase in NAD + levels after rucaparib treatment compared with untreated mouse liver, and a significant decrease in NAD + levels in the temozolomide-treated group. The combination of rucaparib and temozolomide did not prevent the NAD + depletion caused by temozolomide treatment. The 1 H-MRS results show that NAD + levels can be used as a biomarker of PARP inhibitor and methylating agent treatments, and suggest that in vivo measurement of NAD + would be valuable. Copyright © 2017 John Wiley & Sons, Ltd.
Manic symptoms and impulsivity during bipolar depressive episodes
Swann, Alan C; Moeller, F Gerard; Steinberg, Joel L; Schneider, Laurie; Barratt, Ernest S; Dougherty, Donald M
2009-01-01
Objectives In contrast to the extensive literature on the frequent occurrence of depressive symptoms in manic patients, there is little information about manic symptoms in bipolar depressions. Impulsivity is a prominent component of the manic syndrome, so manic features during depressive syndromes may be associated with impulsivity and its consequences, including increased risk of substance abuse and suicidal behavior. Therefore, we investigated the prevalence of manic symptoms and their relationships to impulsivity and clinical characteristics in patients with bipolar depressive episodes. Methods In 56 bipolar I or II depressed subjects, we investigated the presence of manic symptoms, using Mania Rating Scale (MRS) scores from the Schedule for Affective Disorders and Schizophrenia (SADS), and examined its association with other psychiatric symptoms (depression, anxiety, and psychosis), age of onset, history of alcohol and/or other substance abuse and of suicidal behavior, and measures of impulsivity. Results MRS ranged from 0 to 29 (25th–75th percentile, range 4–13), and correlated significantly with anxiety and psychosis, but not with depression, suggesting the superimposition of a separate psychopathological mechanism. Impulsivity and history of substance abuse, head trauma, or suicide attempt increased with increasing MRS. Receiver-operating curve analysis showed that MRS could divide patients into two groups based on history of alcohol abuse and suicide attempt, with an inflection point corresponding to an MRS score of 6. Discussion Even modest manic symptoms during bipolar depressive episodes were associated with greater impulsivity, and with histories of alcohol abuse and suicide attempts. Manic symptoms during depressive episodes suggest the presence of a potentially dangerous combination of depression and impulsivity. PMID:17430294
Draganova, R; Schollbach, A; Schleger, F; Braendle, J; Brucker, S; Abele, H; Kagan, K O; Wallwiener, D; Fritsche, A; Eswaran, H; Preissl, H
2018-06-01
The human fetal auditory system is functional around the 25th week of gestational age when the thalamocortical connections are established. Fetal magnetoencephalography (fMEG) provides evidence for fetal auditory brain responses to pure tones and syllables. Fifty-five pregnant women between 31 and 40 weeks of gestation were included in the study. Fetal MEG was recorded during the presentation of an amplitude modulated tone (AM) with a carrier frequency of 500 Hz to the maternal abdomen modulated by low modulation rates (MRs) - 2/s and 4/s, middle MR - 8/s and high MRs - 27/s, 42/s, 78/s and 91/s. The aim was to determine whether the fetal brain responds differently to envelope slopes and intensity change at the onset of the AM sounds. A significant decrease of the response latencies of transient event-related responses (ERR) to high and middle MRs in comparison to the low MRs was observed. The highest fetal response rate was achieved by modulation rates of 2/s, 4/s and 27/s (70%, 57%, and 86%, respectively). Additionally, a maturation effect of the ERR (response latency vs. gestational age) was observed only for 4/s MR. The significant difference between the response latencies to low, middle, and high MRs suggests that still before birth the fetal brain processes the sound slopes at the onset in different integration time-windows, depending on the time for the intensity increase or stimulus power density at the onset, which is a prerequisite for language acquisition. Copyright © 2018 Elsevier B.V. All rights reserved.
Kasthurirathne, Suranga N; Mamlin, Burke W; Cullen, Theresa
2017-02-01
Despite significant awareness on the value of leveraging patient relationships across the healthcare continuum, there is no research on the potential of using Electronic Health Record (EHR) systems to store structured patient relationship data, or its impact on enabling better healthcare. We sought to identify which EHR systems supported effective patient relationship data collection, and for systems that do, what types of relationship data is collected, how this data is used, and the perceived value of doing so. We performed a literature search to identify EHR systems that supported patient relationship data collection. Based on our results, we defined attributes of an effective patient relationship model. The Open Medical Record System (OpenMRS), an open source medical record platform for underserved settings met our eligibility criteria for effective patient relationship collection. We performed a survey to understand how the OpenMRS patient relationship model was used, and how it brought value to implementers. The OpenMRS patient relationship model has won widespread adoption across many implementations and is perceived to be valuable in enabling better health care delivery. Patient relationship information is widely used for community health programs and enabling chronic care. Additionally, many OpenMRS implementers were using this feature to collect custom relationship types for implementation specific needs. We believe that flexible patient relationship data collection is critical for better healthcare, and can inform community care and chronic care initiatives across the world. Additionally, patient relationship data could also be leveraged for many other initiatives such as patient centric care and in the field of precision medicine.
Nasca, C; Bigio, B; Zelli, D; Nicoletti, F; McEwen, B S
2015-06-01
Why do some individuals succumb to stress and develop debilitating psychiatric disorders, whereas others adapt well in the face of adversity? There is a gap in understanding the neural bases of individual differences in the responses to environmental factors on brain development and functions. Here, using a novel approach for screening an inbred population of laboratory animals, we identified two subpopulations of mice: susceptible mice that show mood-related abnormalities compared with resilient mice, which cope better with stress. This approach combined with molecular and behavioral analyses, led us to recognize, in hippocampus, presynaptic mGlu2 receptors, which inhibit glutamate release, as a stress-sensitive marker of individual differences to stress-induced mood disorders. Indeed, genetic mGlu2 deletion in mice results in a more severe susceptibility to stress, mimicking the susceptible mouse sub-population. Furthermore, we describe an underlying mechanism by which glucocorticoids, acting via mineralocorticoid receptors (MRs), decrease resilience to stress via downregulation of mGlu2 receptors. We also provide a mechanistic link between MRs and an epigenetic control of the glutamatergic synapse that underlies susceptibility to stressful experiences. The approach and the epigenetic allostasis concept introduced here serve as a model for identifying individual differences based upon biomarkers and underlying mechanisms and also provide molecular features that may be useful in translation to human behavior and psychopathology.
A bibliography of references to avian cholera
Wilson, Sonoma S.
1979-01-01
Mrs. Wilson has made a genuine effort to include in this bibliography every significant reference to avian cholera since Louis Pasteur's articles appeared in 1880, although she recognizes the likelihood that a few have been overlooked. New listings have been added throughout 1978, but comprehensive coverage of the literature cannot be claimed beyond June of that year.Textbook accounts, because they are generally summaries of work published elsewhere, are excluded. Papers dealing primarily with the biology of Pasteurella multocida, as opposed to the disease it induces in birds, are also excluded, unless they report information of diagnostic usefulness. Short abstracts are not included unless the journals in which they are published are more widely available than those in which the complete articles appear or they are English summaries of foreign language articles.In compiling this bibliography, Mrs. Wilson has made extensive use of Biological Abstracts, the Pesticide Documentation Bulletin, and printouts generated by Bibliographic Retrieval Services, Inc. The "Literature Cited" sections of textbooks and journal articles pertinent to the subject were sources of many additional references. Regardless of the origin of the citation, its accuracy was confirmed by comparison with the original publication, except in those few instances (marked with an asterisk) when the journal was not on the shelves of the libraries accessible to us.The author will be grateful to users of the bibliography who point out errors or omissions.Wayne I. JensenMicrobiologist In Charge
Mrs. O'Leary's Cow and Other Newspaper Tales about the Chicago Fire of 1871.
ERIC Educational Resources Information Center
Fedler, Fred
Noting that, historically, newspaper editors copied the best, and sometimes erroneous, stories from other newspapers published in distant cities, this paper explores newpaper coverage of the 1871 Great Chicago Fire, and the myth that Mrs. O'Leary's cow was to blame. After suggesting that a report invented the story of the O'Leary cow kicking a…
32 CFR Appendix A to Part 327 - Sample DeCA Response Letter
Code of Federal Regulations, 2012 CFR
2012-07-01
... 32 National Defense 2 2012-07-01 2012-07-01 false Sample DeCA Response Letter A Appendix A to Part...) PRIVACY PROGRAM DEFENSE COMMISSARY AGENCY PRIVACY ACT PROGRAM Pt. 327, App. A Appendix A to Part 327—Sample DeCA Response Letter Mrs. Floria Employee 551 Florida Avenue Oakland, CA 94618 Dear Mrs. Employee...
ERIC Educational Resources Information Center
Cohen, Robert
1996-01-01
Utilizes letters to the First Lady and President Roosevelt as primary sources for a series of activities supporting a unit on the Great Depression. The letter to Mrs. Roosevelt asks for some old clothes for a needy family. The letter to President Roosevelt expresses dissatisfaction with his efforts. (MJP)
ERIC Educational Resources Information Center
Asmundson, Gordon J. G.; Hadjistavrpolous, Heather D.
2004-01-01
Patients with health anxiety often present challenges to assessment and treatment planning. The case of Mrs. A. provides examples of several clinical issues common to these patients. Her symptoms cross several "DSM" diagnostic categories, with a primary presentation of hypochondriasis and secondary presentation of illness phobia. In this article,…
The People Next Door: Getting along with the Neighbors in "Yoo-Hoo Mrs. Goldberg" and "District 9"
ERIC Educational Resources Information Center
Beck, Bernard
2010-01-01
Two different perspectives on the immigrant struggles are found in a documentary about the radio and television program "The Goldbergs" and a science fiction thriller about the treatment of an immigrant alien community. "Yoo-Hoo Mrs. Goldberg" is optimistic and celebrates the achievements of an established ethnic community in America and the woman…
Presidential Spouses: Worth Taking Seriously, and Worth Paying
ERIC Educational Resources Information Center
Moser, Kate
2008-01-01
Mrs. Deborah J. Cofer is one of many presidential spouses who balk at the thought of being paid for their work--whether because they relish the freedom to take a night off or because they think of it as a natural part of their relationships with their partners. Mrs. Cofer believes that their mission is to enhance students' lives and they do not…
ACHP | News | Mrs. Laura Bush Announces Preserve America Community
Sept. 15, 2003, Mobile, AlabamaÂMrs. Laura Bush today announced details of two new key components of continue to build upon. Mobile is a great example of a community that is using its past to build a better recognition program included ACHP member Emily Summers; Mobile, AL, mayor Mike Dow; Secretary of the Interior
Code of Federal Regulations, 2010 CFR
2010-10-01
... provides. (2) Example— Mr. Smith works for employer A, and he and his wife are covered through employer A's GHP (Plan A). Neither is eligible for Medicare nor has ESRD. Mrs. Smith works for employer B, and is... items and services which Plan B does not cover, such as prescription drugs. If Mrs. Smith obtains a...
Jafari, Jafar
2012-01-01
Swallowing induces an inhibitory wave that is followed by a contractile wave along the esophageal body. Deglutitive inhibition in the skeletal muscle of the esophagus is controlled in the brain stem whilst in the smooth muscle, an intrinsic peripheral control mechanism is critical. The latency between swallow and contractions is determined by the pattern of activation of the inhibitory and excitatory vagal pathways, the regional gradients of inhibitory and excitatory myenteric nerves, and the intrinsic properties of the smooth muscle. A wave of inhibition precedes a swallow-induced peristaltic contraction in the smooth muscle part of the human oesophagus involving both circular and longitudinal muscles in a peristaltic fashion. Deglutitive inhibition is necessary for drinking liquids which requires multiple rapid swallows (MRS). During MRS the esophageal body remains inhibited until the last of the series of swallows and then a peristaltic contraction wave follows. A normal response to MRS requires indemnity of both inhibitory and excitatory mechanisms and esophageal muscle. MRS has recently been used to assess deglutitive inhibition in patients with esophageal motor disorders. Examples with impairment of deglutitive inhibition are achalasia of the LES and diffuse esophageal spasm. PMID:22323983
Sifrim, Daniel; Jafari, Jafar
2012-01-01
Swallowing induces an inhibitory wave that is followed by a contractile wave along the esophageal body. Deglutitive inhibition in the skeletal muscle of the esophagus is controlled in the brain stem whilst in the smooth muscle, an intrinsic peripheral control mechanism is critical. The latency between swallow and contractions is determined by the pattern of activation of the inhibitory and excitatory vagal pathways, the regional gradients of inhibitory and excitatory myenteric nerves, and the intrinsic properties of the smooth muscle. A wave of inhibition precedes a swallow-induced peristaltic contraction in the smooth muscle part of the human oesophagus involving both circular and longitudinal muscles in a peristaltic fashion. Deglutitive inhibition is necessary for drinking liquids which requires multiple rapid swallows (MRS). During MRS the esophageal body remains inhibited until the last of the series of swallows and then a peristaltic contraction wave follows. A normal response to MRS requires indemnity of both inhibitory and excitatory mechanisms and esophageal muscle. MRS has recently been used to assess deglutitive inhibition in patients with esophageal motor disorders. Examples with impairment of deglutitive inhibition are achalasia of the LES and diffuse esophageal spasm.
Growth of cyanobacteria on Martian Regolith Simulant after exposure to vacuum
NASA Astrophysics Data System (ADS)
Arai, Mayumi; Sato, Seigo; Ohmori, Masayuki; Tomita-Yokotani, Kaori; Hashimoto, Hirofumi; Yamashita, Masamichi
Habitation on Mars is one of our challenges in this century. The growth of cyanobacteria on Martian Regolith Simulant (MRS) was studied with two species of terrestrial cyanobacteria, Nostoc, and one species of other cyanobacterium, Synechosystis. Their vacuum tolerances was examined in order to judge feasibility of the use of cyanobacteria to creat habitable environment on a distant planet. The viability of cyanobacteria tested was evaluated by the microscopic observation after staining by FDA (fluorescein diacetate). A part of them were also re-incubated again in a liquid culture medium, and viability and the chlorophyll production were examined in detail. Nostoc was found to grow for over 140 days with their having normal function of chlorophyll synthesis on the MRS. After the exposure to high vacuum environment (10-5 Pa) for a year, Nostoc sp. started growth. Chlorophyll was produced after this vacuum exposure as well. The A'MED (Arai's Mars Ecosystem Dome, A'MED) is designed to install on Mars for conducting agricultural production in it. We performed the fundamental experiment with MRS. These results show a possibility that cyanobacteria could adapt to MRS, and grow under the low pressure environment expected on Mars.
Malek, Mahrooz; Pourashraf, Maryam; Gilani, Mitra Modares; Gity, Masoumeh
2015-01-01
The aim of this study was to assess the role of the presence of a choline peak in 3 Tesla 1H magnetic resonance spectroscopy (MRS) for differentiating benign from malignant adnexal masses. A total of 46 adnexal masses (23 malignant and 23 benign) underwent 1H MRS study prior to surgery to assess the presence of choline peak. A choline peak was detected in 16 malignant masses (69.5%) and was absent in the other 7 (30.5%). A choline peak was only detected in 6 (26%) of the benign adnexal masses. The presence of an MRS choline peak had a sensitivity of 69.5%, a specificity of 74%, a positive predictive value (PPV) of 72.7%, and a negative predictive value (NPV) of 71% for diagnosing malignant adnexal masses. A significant difference between the frequency of mean choline peaks in benign and malignant adnexal masses was observed (P value<0.01). A 1H MRS choline peak is seen in malignant adnexal masses more frequently than the benign masses, and may be helpful for diagnosing malignant adnexal masses.
Partial volume correction of magnetic resonance spectroscopic imaging
NASA Astrophysics Data System (ADS)
Lu, Yao; Wu, Dee; Magnotta, Vincent A.
2007-03-01
The ability to study the biochemical composition of the brain is becoming important to better understand neurodegenerative and neurodevelopmental disorders. Magnetic Resonance Spectroscopy (MRS) can non-invasively provide quantification of brain metabolites in localized regions. The reliability of MRS is limited in part due to partial volume artifacts. This results from the relatively large voxels that are required to acquire sufficient signal-to-noise ratios for the studies. Partial volume artifacts result when a MRS voxel contains a mixture of tissue types. Concentrations of metabolites vary from tissue to tissue. When a voxel contains a heterogeneous tissue composition, the spectroscopic signal acquired from this voxel will consist of the signal from different tissues making reliable measurements difficult. We have developed a novel tool for the estimation of partial volume tissue composition within MRS voxels thus allowing for the correction of partial volume artifacts. In addition, the tool can localize MR spectra to anatomical regions of interest. The tool uses tissue classification information acquired as part of a structural MR scan for the same subject. The tissue classification information is co-registered with the spectroscopic data. The user can quantify the partial volume composition of each voxel and use this information as covariates for metabolite concentrations.
Cağlar, Ertunga; Sabuncuoğlu, Hakan; Keskin, Tülay; Isikli, Sedat; Keskil, Semih; Korkusuz, Feza
2005-01-01
Our aim was to disclose whether the positive psychological changes observed after a single bout of aerobic exercise have a biochemical correlate that can be visualized by proton magnetic resonance spectroscopy (MRS) of the human brain. Right-handed male volunteers underwent psychological testing and MRS of the frontal lobe of the left hemisphere, both before and after 20 minutes of jogging at about 70% of their maximal aerobic capacity. Although there was a significant decrease on the postexercise anxiety test scores (z = -2.201, P < .05), there was no significant difference between the preexercise and postexercise scores of positive and negative affect. Considering both "amplitude" and "area under the curve" values calculated for the peaks of metabolites N-acetylaspartate (NAA), creatine, and choline, none were found to be significantly changed (P > .05) after the exercise. This is, to our knowledge, the first study to report on a functional application of MRS to mood states. Because it offers the ability to directly measure metabolic changes in the brain during neuronal activation, "functional MRS" may be a potential new tool that may be used as an adjunct to functional magnetic resonance imaging.
Brain tumor response to nimotuzumab treatment evaluated on magnetic resonance imaging.
Dalmau, Evelio Rafael González; Cabal Mirabal, Carlos; Martínez, Giselle Saurez; Dávila, Agustín Lage; Suárez, José Carlos Ugarte; Cabanas Armada, Ricardo; Rodriguez Cruz, Gretel; Darias Zayas, Daniel; Castillo, Martha Ríos; Valle Garrido, Luis; Sotolongo, Luis Quevedo; Fernández, Mercedes Monzón
2014-02-01
Nimotuzumab, a humanized monoclonal antibody anti-epidermal growth factor receptor, has been shown to improve survival and quality of life in patients with pediatric malignant brain tumor. It is necessary, however, to increase the objective response criteria to define the optimal therapeutic schedule. The aim of this study was to obtain magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS) quantitative information related to dimensions and morphology, molecular mobility and metabolic activity of the lesion and surroundings in order to evaluate any changes through time. Fourteen pediatric patients treated with nimotuzumab were evaluated on MRI and MRS for >2 years. Each patient was their own control. The MRI/MRS pulse sequence parameters were standardized to ensure experimental reproducibility. A total of 71.4% of patients had stable disease; 21.4% had objective response and 7.1% had progression of disease during the >2 year evaluation period. MRI/MRS data with clinical information provide a clearer picture of treatment response and confirm once again that nimotuzumab is effective in the treatment of pediatric brain tumor. These imaging procedures can be a useful tool for the clinical evaluation of study protocol in clinical practice. © 2013 The Authors. Pediatrics International © 2013 Japan Pediatric Society.
Kim, Mi-Hee; Kong, Yoon-Jung; Baek, Hong; Hyun, Hyung-Hwan
2006-01-02
To enhance the production of micrococcin GO5, a bacteriocin produced by Micrococcus sp. GO5, cultivation conditions and medium composition were optimized. The optimal initial pH and temperature for bacteriocin production were 7.0-9.0 and 37 degrees C, respectively. Micrococcus sp. GO5 displayed the highest micrococcin GO5 activity when grown in modified MRS medium that contained lactose or sucrose, rather than glucose, as a carbon source. The maximum bacteriocin activity was obtained in modified MRS medium containing 0.5% tryptone and 1.0% yeast extract as nitrogen sources instead of the other nitrogen sources present in MRS medium. Bacteriocin production was greatly affected by the concentration of K(2)HPO(4); strain GO5 produced eight-fold more bacteriocin in medium containing 2.0-2.5% K(2)HPO(4) than in medium containing 0.2% K(2)HPO(4). The optimal concentration of MgSO(4).7H(2)O for bacteriocin production was 0.5%. The production of micrococcin GO5 was increased 32-fold in shake flask culture and 16-fold in a bioreactor using the optimized medium (TY medium), compared with culturing in MRS medium.
Campbell, Bruce C V; Mitchell, Peter J; Churilov, Leonid; Keshtkaran, Mahsa; Hong, Keun-Sik; Kleinig, Timothy J; Dewey, Helen M; Yassi, Nawaf; Yan, Bernard; Dowling, Richard J; Parsons, Mark W; Wu, Teddy Y; Brooks, Mark; Simpson, Marion A; Miteff, Ferdinand; Levi, Christopher R; Krause, Martin; Harrington, Timothy J; Faulder, Kenneth C; Steinfort, Brendan S; Ang, Timothy; Scroop, Rebecca; Barber, P Alan; McGuinness, Ben; Wijeratne, Tissa; Phan, Thanh G; Chong, Winston; Chandra, Ronil V; Bladin, Christopher F; Rice, Henry; de Villiers, Laetitia; Ma, Henry; Desmond, Patricia M; Meretoja, Atte; Cadilhac, Dominique A; Donnan, Geoffrey A; Davis, Stephen M
2017-01-01
Endovascular thrombectomy improves functional outcome in large vessel occlusion ischemic stroke. We examined disability, quality of life, survival and acute care costs in the EXTEND-IA trial, which used CT-perfusion imaging selection. Large vessel ischemic stroke patients with favorable CT-perfusion were randomized to endovascular thrombectomy after alteplase versus alteplase-only. Clinical outcome was prospectively measured using 90-day modified Rankin scale (mRS). Individual patient expected survival and net difference in Disability/Quality-adjusted life years (DALY/QALY) up to 15 years from stroke were modeled using age, sex, 90-day mRS, and utility scores. Level of care within the first 90 days was prospectively measured and used to estimate procedure and inpatient care costs (US$ reference year 2014). There were 70 patients, 35 in each arm, mean age 69, median NIHSS 15 (IQR 12-19). The median (IQR) disability-weighted utility score at 90 days was 0.65 (0.00-0.91) in the alteplase-only versus 0.91 (0.65-1.00) in the endovascular group ( p = 0.005). Modeled life expectancy was greater in the endovascular versus alteplase-only group (median 15.6 versus 11.2 years, p = 0.02). The endovascular thrombectomy group had fewer simulated DALYs lost over 15 years [median (IQR) 5.5 (3.2-8.7) versus 8.9 (4.7-13.8), p = 0.02] and more QALY gained [median (IQR) 9.3 (4.2-13.1) versus 4.9 (0.3-8.5), p = 0.03]. Endovascular patients spent less time in hospital [median (IQR) 5 (3-11) days versus 8 (5-14) days, p = 0.04] and rehabilitation [median (IQR) 0 (0-28) versus 27 (0-65) days, p = 0.03]. The estimated inpatient costs in the first 90 days were less in the thrombectomy group (average US$15,689 versus US$30,569, p = 0.008) offsetting the costs of interhospital transport and the thrombectomy procedure (average US$10,515). The average saving per patient treated with thrombectomy was US$4,365. Thrombectomy patients with large vessel occlusion and salvageable tissue on CT-perfusion had reduced length of stay and overall costs to 90 days. There was evidence of clinically relevant improvement in long-term survival and quality of life. http://www.ClinicalTrials.gov NCT01492725 (registered 20/11/2011).
Development of the network architecture of the Canadian MSAT system
NASA Technical Reports Server (NTRS)
Davies, N. George; Shoamanesh, Alireza; Leung, Victor C. M.
1988-01-01
A description is given of the present concept for the Canadian Mobile Satellite (MSAT) System and the development of the network architecture which will accommodate the planned family of three categories of service: a mobile radio service (MRS), a mobile telephone service (MTS), and a mobile data service (MDS). The MSAT satellite will have cross-strapped L-band and Ku-band transponders to provide communications services between L-band mobile terminals and fixed base stations supporting dispatcher-type MRS, gateway stations supporting MTS interconnections to the public telephone network, data hub stations supporting the MDS, and the network control center. The currently perceived centralized architecture with demand assignment multiple access for the circuit switched MRS, MTS and permanently assigned channels for the packet switched MDS is discussed.
Development of the network architecture of the Canadian MSAT system
NASA Astrophysics Data System (ADS)
Davies, N. George; Shoamanesh, Alireza; Leung, Victor C. M.
1988-05-01
A description is given of the present concept for the Canadian Mobile Satellite (MSAT) System and the development of the network architecture which will accommodate the planned family of three categories of service: a mobile radio service (MRS), a mobile telephone service (MTS), and a mobile data service (MDS). The MSAT satellite will have cross-strapped L-band and Ku-band transponders to provide communications services between L-band mobile terminals and fixed base stations supporting dispatcher-type MRS, gateway stations supporting MTS interconnections to the public telephone network, data hub stations supporting the MDS, and the network control center. The currently perceived centralized architecture with demand assignment multiple access for the circuit switched MRS, MTS and permanently assigned channels for the packet switched MDS is discussed.
del Mar Matarín, María; Pueyo, Roser; Poca, María Antonia; Falcón, Carles; Mataró, María; Bargalló, Núria; Sahuquillo, Juan; Junqué, Carme
2007-01-01
Background Adult normal pressure hydrocephalus (NPH) is one of the few potentially treatable causes of dementia. Some morphological and functional abnormalities attributed to hydrocephalus improve following treatment. Objectives We focused on analysis of changes in cerebral metabolites using proton magnetic resonance spectroscopy (1H‐MRS) after NPH treatment, and its clinical and cognitive correlation. Methods 1H‐MRS, neuropsychological and clinical status examinations were performed before and 6 months after shunting in 12 adults with idiopathic NPH. We obtained N‐acetyl‐aspartate (NAA), choline (Cho), myoinositol (MI) and creatine (Cr) values. Results After surgery, NAA/Cr was significantly increased. Moreover, NAA/Cr values were related to cognitive deterioration. Conclusion MRS could be a marker of neuronal dysfunction in NPH. PMID:17299021
Sun, Yingwei; Pan, Shinong; Chen, Zhian; Zhao, Heng; Ma, Ying; Zheng, Liqiang; Li, Qi; Deng, Chunbo; Fu, Xihu; Lu, Zaiming; Guo, Qiyong
2014-01-01
Little is known about the value of (31)P-magnetic resonance spectroscopy ((31)P-MRS) in in vivo assessment of exhaustive exercise-induced injury in skeletal muscle. We aimed to evaluate the value of a (31)P-MRS study using the quadriceps femoris after a single bout of acute exhaustive swimming in rats, and the correlation between (31)P-MRS and histological changes. Sixty male Sprague-Dawley rats were randomly assigned to control, half-exhaustive, and exhaustive exercise groups. (31)P-MRS of the quadriceps femoris of the right lower limb was performed immediately after swimming exercise to detect Pi, PCr, and β-ATP. The Pi/PCr, Pi/β-ATP, PCr/β-ATP, and PCr/(PCr+Pi) were calculated and pH measured. Areas under the receiver operating characteristic curve (AUCs) were calculated to evaluate the diagnostic potential of (31)P-MRS in identifying and distinguishing the three groups. HE staining, electron microscopy and desmin immunostaining after imaging of the muscle were used as a reference standard. The correlation between (31)P-MRS and the mean absorbance (A value) of desmin staining were analyzed with the Pearson correlation test. Pi, PCr, Pi/PCr, and PCr/(PCr+Pi) showed statistically significant intergroup differences (P < 0.05). AUCs of Pi, PCr, Pi/PCr, and PCr/(PCr+Pi) were 0.905, 0.848, 0.930, and 0.930 for the control and half-exhaustive groups, while sensitivity and specificity were 90%/85%, 95%/55%, 95%/80%, and 90%/85%, respectively. The AUCs of Pi, PCr, Pi/PCr and PCr/(PCr+Pi) were 0.995, 0.980, 1.000, and 1.000 for the control and exhaustive groups, while sensitivity and specificity were 95%/90%, 100%/90%, 100%/95%, and 100%/95%, respectively. The AUCs of Pi, PCr, Pi/PCr, and PCr/(PCr+Pi) were 0.735, 0.865, 0.903, and 0.903 for the half-exhaustive and exhaustive groups, while sensitivity and specificity were 80%/60%, 90%/75%, 95%/65%, and 95%/70%, respectively. In the half-exhaustive group, some muscle fibers exhibited edema in HE staining, and the unclear Z-discs and the mitochondria with vacuolar degeneration under electron microscopy. Compared with the half-exhaustive group, muscle fiber edema was increased in the exhaustive group, and the Z-discs were broken and the mitochondria exhibited marked vacuolar degeneration under electron microscopy. There were significant difference in A values of desmin staining in the right vastus lateralis among the control, half-exhaustive, and exhaustive groups with 0.58 ± 0.06, 0.30 ± 0.04, and 0.21 ± 0.02, respectively (P < 0.05). Histological examination also showed injury-induced changes in the vastus lateralis among the different intensities groups. Statistically a moderate correlation between (31)P-MRS and desmin was observed, the correlation coefficients of Pi, PCr, Pi/PCr, and PCr/(PCr+Pi) were -0.706, 0.709, -0.726, and 0.791, respectively (P < 0.01). (31)P-MRS can effectively reflect the changes in energy metabolism in the skeletal muscle after a single bout of acute exhaustive swimming in rats. Based on the significant correlation between (31)P-MRS parameters and histological changes, the changes of Pi, PCr, Pi/PCr, and PCr/(PCr+Pi) can indirectly reflect the degree of exercise-induced injury.
A retrospective survey on injuries in Croatian football/soccer referees
2013-01-01
Background Injury among soccer referees is rarely studied, especially with regard to differences in the quality level of the refereeing. Additionally, we have found no study that has reported injury occurrence during official physical fitness testing for soccer referees. The aim of this study was to investigate the frequency, type and consequences of match-related and fitness-testing related injuries among soccer referees of different competitive levels. Methods We studied 342 soccer referees (all males; mean age 32.9 ± 5.02 years). The study was retrospective, and a self-administered questionnaire was used. In the first phase of the study, the questionnaire was tested for its reliability and applicability. The questionnaire included morphological/anthropometric data, refereeing variables, and musculoskeletal disorders together with the consequences. Results The sample comprised 157 main referees (MR; mean age 31.4 ± 4.9 years) and 185 assistant referees (AR; mean age 34.1 ± 5.1 years) divided into: international level (Union of European Football Associations-UEFA) referees (N = 18; 6 MRs; 12 ARs) ; 1st (N = 78; 31 MRs; 47 ARs), 2nd (N = 91; 45 MRs; 46 ARs); or 3rd national level referees (N = 155; 75 MRs; 80 ARs). In total, 29% (95%CI: 0.23–0.37) of the MRs and 30% (95%CI: 0.22–0.36) of the ARs had experienced an injury during the previous year, while 13% (95%CI: 0.05–0.14) of the MRs, and 19% (95%CI: 0.14–0.25) of the ARs suffered from an injury that occurred during fitness testing. There was an obvious increase in injury severity as the refereeing advanced at the national level, but the UEFA referees were the least injured of all referees. The results showed a relatively high prevalence of injuries to the upper leg (i.e., quadriceps and hamstrings) during physical fitness testing for all but the UEFA referees. During game refereeing, the ankles and lower legs were the most commonly injured regions. The MRs primarily injured their ankles. The ARs experienced lower leg and lower back disorders. However, the overall injury rate was equal for both groups, with 5.29 (95%CI: 2.23–8.30) and 4.58 (95%CI: 2.63–6.54) injuries per 1000 hours of refereeing for MRs and ARs, respectively. Conclusion In addition to the reported risk of injury during soccer games, physical fitness testing should be classified as a risk for injury among soccer referees. Special attention should be given to (I) lower leg injuries during games and (II) upper leg injuries during physical fitness tests. A higher physical fitness level and a qualitative approach to training are recognized as protective factors against injury. Subsequent studies should investigate the specific predictors of injuries among referees. PMID:23497316
Succi, Mariantonietta; Pannella, Gianfranco; Tremonte, Patrizio; Tipaldi, Luca; Coppola, Raffaele; Iorizzo, Massimo; Lombardi, Silvia Jane; Sorrentino, Elena
2017-01-01
Forty-two oenological strains of Lb. plantarum were assessed for their response to ethanol and pH values generally encountered in wines. Strains showed a higher variability in the survival when exposed to low pH (3.5 or 3.0) than when exposed to ethanol (10 or 14%). The study allowed to individuate the highest ethanol concentration (8%) and the lowest pH value (4.0) for the growth of strains, even if the maximum specific growth rate (μmax) resulted significantly reduced by these conditions. Two strains (GT1 and LT11) preadapted to 2% ethanol and cultured up to 14% of ethanol showed a higher growth than those non-preadapted when they were cultivated at 8% of ethanol. The evaluation of the same strains preadapted to low pH values (5.0 and 4.0) and then grown at pH 3.5 or 3.0 showed only for GT1 a sensitive μmax increment when it was cultivated in MRS at pH 3 after a preadaptation to pH 5.0. The survival of GT1 and LT11 was evaluated in Ringer's solution at 14% ethanol after a long-term adaptation in MRS with 2% ethanol or in MRS with 2% ethanol acidified at pH 5.0 (both conditions, BC). Analogously, the survival was evaluated at pH 3.5 after a long-term adaptation in MRS at pH 5.0 or in MRS BC. The impact of the physiologic state (exponential phase vs stationary phase) on the survival was also evaluated. Preadapted cells showed the same behavior of non-preadapted cells only when cultures were recovered in the stationary phase. Mathematical functions were individuated for the description of the survival of GT1 and LT11 in MRS at 14% ethanol or at pH 3.5. Finally, a synthetic wine (SW) was used to assess the behavior of Lb. plantarum GT1 and LT11 preadapted in MRS at 2% ethanol or at pH 5.0 or in BC. Only GT1 preadapted to pH 5.0 and collected in the stationary phase showed constant values of microbial counts after incubation for 15 days at 20°C. In addition, after 15 days the L-malic acid resulted completely degraded and the pH value increased of about 0.3 units. PMID:28382030
2012-01-01
Background In-vivo single voxel proton magnetic resonance spectroscopy (SV 1H-MRS), coupled with supervised pattern recognition (PR) methods, has been widely used in clinical studies of discrimination of brain tumour types and follow-up of patients bearing abnormal brain masses. SV 1H-MRS provides useful biochemical information about the metabolic state of tumours and can be performed at short (< 45 ms) or long (> 45 ms) echo time (TE), each with particular advantages. Short-TE spectra are more adequate for detecting lipids, while the long-TE provides a much flatter signal baseline in between peaks but also negative signals for metabolites such as lactate. Both, lipids and lactate, are respectively indicative of specific metabolic processes taking place. Ideally, the information provided by both TE should be of use for clinical purposes. In this study, we characterise the performance of a range of Non-negative Matrix Factorisation (NMF) methods in two respects: first, to derive sources correlated with the mean spectra of known tissue types (tumours and normal tissue); second, taking the best performing NMF method for source separation, we compare its accuracy for class assignment when using the mixing matrix directly as a basis for classification, as against using the method for dimensionality reduction (DR). For this, we used SV 1H-MRS data with positive and negative peaks, from a widely tested SV 1H-MRS human brain tumour database. Results The results reported in this paper reveal the advantage of using a recently described variant of NMF, namely Convex-NMF, as an unsupervised method of source extraction from SV1H-MRS. Most of the sources extracted in our experiments closely correspond to the mean spectra of some of the analysed tumour types. This similarity allows accurate diagnostic predictions to be made both in fully unsupervised mode and using Convex-NMF as a DR step previous to standard supervised classification. The obtained results are comparable to, or more accurate than those obtained with supervised techniques. Conclusions The unsupervised properties of Convex-NMF place this approach one step ahead of classical label-requiring supervised methods for the discrimination of brain tumour types, as it accounts for their increasingly recognised molecular subtype heterogeneity. The application of Convex-NMF in computer assisted decision support systems is expected to facilitate further improvements in the uptake of MRS-derived information by clinicians. PMID:22401579
Brolin, Robert E; Cody, Ronald P; Marcella, Stephen W
2015-01-01
The Obesity Surgery Mortality Risk Score (OS-MRS) was developed to ascertain preoperative mortality risk of patients having bariatric surgery. To date there has not been a comparison between open and laparoscopic operations using the OS-MRS. To determine whether there are differences in mortality risk between open and laparoscopic Roux-en-Y Gastric Bypass (RYGB) using the OS-MRS. Three university-affiliated hospitals. The 90-day mortality of 2467 consecutive patients who had primary open (1574) or laparoscopic (893) RYGB performed by one surgeon was determined. Univariate and multivariate analysis using 5 OS-MRS risk factors including body mass index (BMI) gender, age>45, presence of hypertension and preoperative deep vein thrombosis (DVT) risk was performed in each group. Each patient was placed in 1 of 3 OS-MRS risk classes based on the number of risks: A (0-1), B (2-3), and C (4-5). Preoperative BMI and DVT risk factors were significantly greater in the open group (OG). Preoperative age was significantly greater in the laparoscopic group (LG). There were significantly more class B and C patients in LG. Ninety-day mortality rates for OG and LG patients were 1.0% and .9%, respectively. Pulmonary embolism was the most common cause of death. All deaths in LG occurred during first 4 years of that experience. Mortality rate by class was A = .1%; B = 1.5%; C = 2.3%. The difference in mortality between class B and C patients was not significant. Univariate analysis in the OG indicated that BMI, age, gender, and DVT risk were significant predictors of mortality. In the LG only BMI and DVT were significant predictors of death. Presence of hypertension was not a significant predictor in either group. Multivariate analysis excluding hypertension found that age was predictive of mortality in the OG while BMI (P = .057) and gender (P = .065) approached statistical significance. Conversely, only BMI was predictive of mortality in the LG with age approaching significance (P = .058). In multivariate analysis DVT risk was not predictive of mortality in either group. There are significant differences in the predictive value of the OS-MRS between open and laparoscopic RYGB. Although laparoscopic patients were significantly older versus the open patients, age was not predictive of mortality after laparoscopic RYGB. BMI trended toward increased mortality risk in both groups. Changes in technique and protocol likely contributed toward no mortality during the last 6 years of our laparoscopic experience. Copyright © 2015 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.
Park, Charlie C; Hooker, Catherine; Hooker, Jonathan C; Bass, Emily; Haufe, William; Schlein, Alexandra; Covarrubias, Yesenia; Heba, Elhamy; Bydder, Mark; Wolfson, Tanya; Gamst, Anthony; Loomba, Rohit; Schwimmer, Jeffrey; Hernando, Diego; Reeder, Scott B; Middleton, Michael; Sirlin, Claude B; Hamilton, Gavin
2018-04-29
Improving the signal-to-noise ratio (SNR) of chemical-shift-encoded MRI acquisition with complex reconstruction (MRI-C) may improve the accuracy and precision of noninvasive proton density fat fraction (PDFF) quantification in patients with hepatic steatosis. To assess the accuracy of high SNR (Hi-SNR) MRI-C versus standard MRI-C acquisition to estimate hepatic PDFF in adult and pediatric nonalcoholic fatty liver disease (NAFLD) using an MR spectroscopy (MRS) sequence as the reference standard. Prospective. In all, 231 adult and pediatric patients with known or suspected NAFLD. PDFF estimated at 3T by three MR techniques: standard MRI-C; a Hi-SNR MRI-C variant with increased slice thickness, decreased matrix size, and no parallel imaging; and MRS (reference standard). MRI-PDFF was measured by image analysts using a region of interest coregistered with the MRS-PDFF voxel. Linear regression analyses were used to assess accuracy and precision of MRI-estimated PDFF for MRS-PDFF as a function of MRI-PDFF using the standard and Hi-SNR MRI-C for all patients and for patients with MRS-PDFF <10%. In all, 271 exams from 231 patients were included (mean MRS-PDFF: 12.6% [SD: 10.4]; range: 0.9-41.9). High agreement between MRI-PDFF and MRS-PDFF was demonstrated across the overall range of PDFF, with a regression slope of 1.035 for the standard MRI-C and 1.008 for Hi-SNR MRI-C. Hi-SNR MRI-C, compared to standard MRI-C, provided small but statistically significant improvements in the slope (respectively, 1.008 vs. 1.035, P = 0.004) and mean bias (0.412 vs. 0.673, P < 0.0001) overall. In the low-fat patients only, Hi-SNR MRI-C provided improvements in the slope (1.058 vs. 1.190, P = 0.002), mean bias (0.168 vs. 0.368, P = 0.007), intercept (-0.153 vs. -0.796, P < 0.0001), and borderline improvement in the R 2 (0.888 vs. 0.813, P = 0.01). Compared to standard MRI-C, Hi-SNR MRI-C provides slightly higher MRI-PDFF estimation accuracy across the overall range of PDFF and improves both accuracy and precision in the low PDFF range. 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.
President and Mrs. Clinton watch launch of Space Shuttle Discovery
NASA Technical Reports Server (NTRS)
1998-01-01
Watching a successful launch of Space Shuttle Discovery from the roof of the Launch Control Center are (left to right) U.S. President Bill Clinton, First Lady Hillary Rodham Clinton, Astronaut Robert Cabana and NASA Administrator Daniel Goldin. This was the first launch of a Space Shuttle to be viewed by President Clinton, or any President to date. They attended the launch to witness the return to space of American legend John H. Glenn Jr., payload specialist on mission STS-95. Cabana will command the crew of STS-88, the first Space Shuttle mission to carry hardware to space for the assembly of the International Space Station, targeted for liftoff on Dec. 3.
NASA Astrophysics Data System (ADS)
Yang, Chen Ning
2013-05-01
I do not remember whether I had met Prof. S. S. Chern when he was a graduate student of Tsinghua University in Peking (now Beijing) where my father was a mathematics professor, and I was in elementary school. But I do remember how I had met Mrs. Chern for the first time, in early October, 1929, when I was seven years old and she was in junior high school. Her father, Professor Tsen, had been a professor of Mathematics at Tsinghua University already for a number of years, and the Yangs were new comers that fall. The Tsens invited us to their house for dinner and that was when I first made the acquaintence of "big sister Tsen"...
2008-10-01
concentration (M.R. Phillips, M.Wagner, O.Gelhausen, V.Coleman, J.B. Brady, C. Jagadish, E. Malguth, A. Hoffmann, E.M. Goldys , J.J. Rusell; E.MRS...Malguth, A. Hoffmann, E.M. Goldys , J.J. Rusell; E.MRS Fall meeting, Symp. F, (Warsaw, Poland, 2004)); it suggests that the shift towards the red of
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-22
... National Historical Park Advisory Commission will be held at 9:30 a.m., on Friday, November 5, 2010, at... withhold your personal identifying information from public review, we cannot guarantee that we will be able.... Charles J. Weir Mr. Barry A. Passett Mr. James G. McCleaf II Mr. John A. Ziegler Mrs. Mary E. Woodward Mrs...
ERIC Educational Resources Information Center
Dick, Carina; Renes, Susan L.; Strange, Anthony T.
2010-01-01
Mary Lincoln, wife of President Abraham Lincoln, lived a tragic life. Beginning with the death of her mother when she was a little girl, Mrs. Lincoln experienced a number of family deaths, including three brothers, three sons, and the murder of her beloved husband while she sat by his side. In addition to tragedy, Mrs. Lincoln suffered from poor…
Beloueche-Babari, M; Chung, Y-L; Al-Saffar, N M S; Falck-Miniotis, M; Leach, M O
2009-01-01
Developing rational targeted cancer drugs requires the implementation of pharmacodynamic (PD), preferably non-invasive, biomarkers to aid response assessment and patient follow-up. Magnetic resonance spectroscopy (MRS) allows the non-invasive study of tumour metabolism. We describe the MRS-detectable PD biomarkers resulting from the action of targeted therapeutics, and discuss their biological significance and future translation into clinical use. PMID:19935796
ERIC Educational Resources Information Center
Erickson, Laura C.; Scott-Van Zeeland, Ashley A.; Hamilton, Gavin; Lincoln, Alan; Golomb, Beatrice A.
2012-01-01
We piloted a suite of approaches aimed to facilitate a successful series of up to four brain and muscle [superscript 31]Phosphorus-Magnetic Resonance Spectroscopy ([superscript 31]P-MRS) scans performed in one session in 12 "awake", non-sedated subjects (ages 6-18), 6 with autism spectrum disorders (ASD) and 6 controls. We targeted advanced…
Design Structure Matrix (DSM) Methods and Applications for Naval Ship Design
2013-05-23
Fax: 817-257-7227 E-mail: t.browninufetcu.edu Web : www. t vsonbrown i ng. com Administrative/Business Contact: Mrs. Teresa Miles Hendrix, MPA...mail: t.browninu(ajtcii.edu Web : www.tvsonbrownina.com Administrative/Business Contact: Mrs. Teresa Miles Hendrix, MPA Assistant Director of...STAKEHOLDER COM ABORDAGEM DE SISTEMAS ADAPTATIVOS A COMPLEXIDADE John Findlay, Ph D. e Abby Straus, M. Div. IMPLEMENTANDO FLEXIBILIDADE
Implications of the Schiavo Case for Understanding Family Caregiving Issues at the End of Life
ERIC Educational Resources Information Center
Roscoe, Lori A.; Osman, Hana; Haley, William E.
2006-01-01
The case of Mrs. Terri Schiavo illustrates common themes in family caregiving at the end of life but is distinctive from most family caregiving situations in other ways. As occurred in Mrs. Schiavo's case, family members do act as both caregivers and decisionmakers for their loved ones at the end of life, often without the benefit of written…
ERIC Educational Resources Information Center
Cortés, Maria José; Orejuela, Carmen; Castellví, Gemma; Folch, Annabel; Rovira, Lluís; Salvador-Carulla, Luis; Irazábal, Marcia; Muñoz, Silvia; Haro, Josep Maria; Vilella, Elisabet; Martínez-Leal, Rafael
2018-01-01
Strategies for the early detection of autism spectrum disorders (ASD) in people with intellectual developmental disorder (IDD) are urgently needed, but few specific tools have been developed. The present study examines the psychometric properties of the EVTEA-DI, a Spanish adaptation of the PDD-MRS, in a large randomized sample of 979 adults with…
Latin America Report, No. 2716
1983-08-02
presidents are: Councillor Minna Wilmot, Mrs. Violet Neilson, and Mrs. Veronica Palmer. General Secretary of the party, Dr. Paul Rob- ertson...reached on the basis of legal opinions formulated by a group of national investors — headed by ex-Minister Rodrigo Llorente Martinez — which, along...Provincial Bank stock and Llorente Martinez , Fernando Gaviria Cadavid (ex-minister of communications) and other Colombians got in as new stockholders. 2k
Hong, Cheng William; Mamidipalli, Adrija; Hooker, Jonathan C.; Hamilton, Gavin; Wolfson, Tanya; Chen, Dennis H.; Dehkordy, Soudabeh Fazeli; Middleton, Michael S.; Reeder, Scott B.; Loomba, Rohit; Sirlin, Claude B.
2017-01-01
Background Proton density fat fraction (PDFF) estimation requires spectral modeling of the hepatic triglyceride (TG) signal. Deviations in the TG spectrum may occur, leading to bias in PDFF quantification. Purpose To investigate the effects of varying six-peak TG spectral models on PDFF estimation bias. Study Type Retrospective secondary analysis of prospectively acquired clinical research data. Population Forty-four adults with biopsy-confirmed nonalcoholic steatohepatitis. Field Strength/Sequence Confounder-corrected chemical-shift-encoded 3T MRI (using a 2D multiecho gradient-recalled echo technique with magnitude reconstruction) and MR spectroscopy. Assessment In each patient, 61 pairs of colocalized MRI-PDFF and MRS-PDFF values were estimated: one pair used the standard six-peak spectral model, the other 60 were six-peak variants calculated by adjusting spectral model parameters over their biologically plausible ranges. MRI-PDFF values calculated using each variant model and the standard model were compared, and the agreement between MRI-PDFF and MRS-PDFF was assessed. Statistical Tests MRS-PDFF and MRI-PDFF were summarized descriptively. Bland–Altman (BA) analyses were performed between PDFF values calculated using each variant model and the standard model. Linear regressions were performed between BA biases and mean PDFF values for each variant model, and between MRI-PDFF and MRS-PDFF. Results Using the standard model, mean MRS-PDFF of the study population was 17.9±8.0% (range: 4.1–34.3%). The difference between the highest and lowest mean variant MRI-PDFF values was 1.5%. Relative to the standard model, the model with the greatest absolute BA bias overestimated PDFF by 1.2%. Bias increased with increasing PDFF (P < 0.0001 for 59 of the 60 variant models). MRI-PDFF and MRS-PDFF agreed closely for all variant models (R2=0.980, P < 0.0001). Data Conclusion Over a wide range of hepatic fat content, PDFF estimation is robust across the biologically plausible range of TG spectra. Although absolute estimation bias increased with higher PDFF, its magnitude was small and unlikely to be clinically meaningful. Level of Evidence 3 Technical Efficacy Stage 2 PMID:28851124
Chen, Hung-Chieh; Soong, Bing-Wen; Guo, Wan Yuo; Wu, Hsiu-Mei; Chang, Cheng-Yen
2012-01-01
Purpose A broad spectrum of diseases can manifest cerebellar ataxia. In this study, we investigated whether proton magnetic resonance spectroscopy (MRS) may help differentiate spinocerebellar ataxias (SCA) from multiple systemic atrophy- cerebellar type (MSA-C). Material and Methods This prospective study recruited 156 patients with ataxia, including spinocerebellar ataxia (SCA) types 1, 2, 3, 6 and 17 (N = 94) and MSA-C (N = 62), and 44 healthy controls. Single voxel proton MRS in the cerebellar hemispheres and vermis were measured. The differences were evaluated using nonparametric statistic tests. Results When compared with healthy controls, the cerebellar and vermis NAA/Cr and NAA/Cho were lower in all patients(p<0.002). The Cho/Cr was lower in SCA2 and MSA-C (p<0.0005). The NAA/Cr and Cho/Cr were lower in MSA-C or SCA2 comparing with SCA3 or SCA6. The MRS features of SCA1 were in between (p<0.018). The cerebellar NAA/Cho was lower in SCA2 than SCA1, SCA3 or SCA6 (p<0.04). The cerebellar NAA/Cho in MSA-C was lower than SCA3 (p<0.0005). In the early stages of diseases (SARA score<10), significant lower NAA/Cr and NAA/Cho in SCA2, SCA3, SCA6 or MSA-C were observed comparing with healthy controls (p<0.017). The Cho/Cr was lower in MSA-C or SCA2 (p<0.0005). Patients with MSA-C and SCA2 had lower NAA/Cr and Cho/Cr than SCA3 or SCA6 (p<0.016). Conclusion By using MRS, significantly lower NAA/Cr, Cho/Cr and NAA/Cho in the cerebellar hemispheres and vermis were found in patients with ataxia (SCAs and MSA-C). Rapid neuronal degeneration and impairment of membrane activities were observed more often in patients with MSA-C than those with SCA, even in early stages. MRS could also help distinguish between SCA2 and other subtypes of SCAs. MRS ratios may be of use as biomarkers in early stages of disease and should be further assessed in a longitudinal study. PMID:23118909
Navarro, Jose C; Chen, Christopher Lh; Lee, Chun F; Gan, Herminigildo H; Lao, Annabelle Y; Baroque, Alejandro C; Hiyadan, John Harold B; Chua, Carlos L; San Jose, Ma Cristina; Advincula, Joel M; Venketasubramanian, Narayanaswamy
2017-04-01
Background and Aim A pre-specified country analysis of subjects from the Philippines in the CHInese Medicine NeuroAiD Efficacy on Stroke recovery (CHIMES) Study showed significantly improved functional and neurological outcomes on MLC601 at month (M) 3. We aimed to assess these effects on long-term functional recovery in the Filipino cohort. Methods The CHIMES-E (extension) Study evaluated subjects who completed three months of randomized placebo-controlled treatment in CHIMES up to two years. Blinding of treatment allocation was maintained and all subjects received standard stroke care and rehabilitation. Modified Rankin Score (mRS) and Barthel Index (BI) were assessed in-person at M3 and by telephone at M6, M12, M18, M24. Odds ratios (OR) with corresponding 95% confidence intervals (CI) for functional recovery using ordinal analysis of mRS and for achieving functional independence (mRS 0-1 or BI ≥ 95) at each time point were calculated, adjusting for age, sex, baseline National Institute of Health Stroke Scale (NIHSS), onset-to-treatment time (OTT) and pre-stroke mRS. Results The 378 subjects (MLC601 192, placebo 186) included in CHIMES-E from the Philippines (mean age 60.2 ± 11.1) had more women ( p < 0.001), worse baseline NIHSS ( p < 0.001) and longer onset to treatment time ( p = 0.002) compared to other countries. Baseline characteristics were similar between treatment groups. The treatment effect of MLC601 seen at M3 peaked at M6 with OR for mRS shift of 1.53 (95% CI 1.05-2.22), mRS dichotomy 0-1 of 1.77 (95% CI 1.10-2.83), and BI ≥ 95 of 1.87 (95% CI 1.16-3.02). The beneficial effect persisted up to M24. Conclusion The beneficial effect of MLC601 seen at M3 in the Filipino cohort is durable up to two years after stroke.
Hemicraniectomy versus medical treatment with large MCA infarct: a review and meta-analysis.
Alexander, Paul; Heels-Ansdell, Diane; Siemieniuk, Reed; Bhatnagar, Neera; Chang, Yaping; Fei, Yutong; Zhang, Yuqing; McLeod, Shelley; Prasad, Kameshwar; Guyatt, Gordon
2016-11-24
Large middle cerebral artery stroke (space-occupying middle-cerebral-artery (MCA) infarction (SO-MCAi)) results in a very high incidence of death and severe disability. Decompressive hemicraniectomy (DHC) for SO-MCAi results in large reductions in mortality; the level of function in the survivors, and implications, remain controversial. To address the controversy, we pooled available randomised controlled trials (RCTs) that examined the impact of DHC on survival and functional ability in patients with large SO-MCAi and cerebral oedema. We searched MEDLINE, EMBASE and Cochrane library databases for randomised controlled trials (RCTs) enrolling patients suffering SO-MCAi comparing conservative management to DHC administered within 96 hours after stroke symptom onset. Outcomes were death and disability measured by the modified Rankin Scale (mRS). We used a random effects meta-analytical approach with subgroup analyses (time to treatment and age). We applied GRADE methods to rate quality/confidence/certainty of evidence. 7 RCTs were eligible (n=338 patients). We found DHC reduced death (69-30% in medical vs surgical groups, 39% fewer), and increased the number of patients with mRS of 2-3 (slight to moderate disability: 14-27%, increase of 13%), those with mRS 4 (severe disability: 10-32%, increase of 22%) and those with mRS 5 (very severe disability 7-11%: increase of 4%) (all differences p<0.0001). We judged quality/confidence/certainty of evidence high for death, low for functional outcome mRS 0-3, and moderate for mRS 0-4 (wide CIs and problems in concealment, blinding of outcome assessors and stopping early). DHC in SO-MCAi results in large reductions in mortality. Most of those who would otherwise have died are left with severe or very severe disability: for example, inability to walk and a requirement for help with bodily needs, though uncertainty about the proportion with very severe, severe and moderate disability remains (low to moderate quality/confidence/certainty evidence). Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Hemicraniectomy versus medical treatment with large MCA infarct: a review and meta-analysis
Alexander, Paul; Heels-Ansdell, Diane; Siemieniuk, Reed; Bhatnagar, Neera; Chang, Yaping; Fei, Yutong; McLeod, Shelley; Prasad, Kameshwar; Guyatt, Gordon
2016-01-01
Objective Large middle cerebral artery stroke (space-occupying middle-cerebral-artery (MCA) infarction (SO-MCAi)) results in a very high incidence of death and severe disability. Decompressive hemicraniectomy (DHC) for SO-MCAi results in large reductions in mortality; the level of function in the survivors, and implications, remain controversial. To address the controversy, we pooled available randomised controlled trials (RCTs) that examined the impact of DHC on survival and functional ability in patients with large SO-MCAi and cerebral oedema. Methods We searched MEDLINE, EMBASE and Cochrane library databases for randomised controlled trials (RCTs) enrolling patients suffering SO-MCAi comparing conservative management to DHC administered within 96 hours after stroke symptom onset. Outcomes were death and disability measured by the modified Rankin Scale (mRS). We used a random effects meta-analytical approach with subgroup analyses (time to treatment and age). We applied GRADE methods to rate quality/confidence/certainty of evidence. Results 7 RCTs were eligible (n=338 patients). We found DHC reduced death (69–30% in medical vs surgical groups, 39% fewer), and increased the number of patients with mRS of 2–3 (slight to moderate disability: 14–27%, increase of 13%), those with mRS 4 (severe disability: 10–32%, increase of 22%) and those with mRS 5 (very severe disability 7–11%: increase of 4%) (all differences p<0.0001). We judged quality/confidence/certainty of evidence high for death, low for functional outcome mRS 0–3, and moderate for mRS 0–4 (wide CIs and problems in concealment, blinding of outcome assessors and stopping early). Conclusions DHC in SO-MCAi results in large reductions in mortality. Most of those who would otherwise have died are left with severe or very severe disability: for example, inability to walk and a requirement for help with bodily needs, though uncertainty about the proportion with very severe, severe and moderate disability remains (low to moderate quality/confidence/certainty evidence). PMID:27884858
Cheng, Ji-Wei; Zhang, Xiao-Jing; Cheng, Li-Shan; Li, Guo-Yi; Zhang, Li-Jun; Ji, Kang-Xiang; Zhao, Qing; Bai, Yu
2018-02-01
Intravenous thrombolysis using tissue plasminogen activator (tPA) improves significantly the neurologic function in patients with acute ischemic stroke (AIS). However, it brings financial burden to patients and is associated with symptomatic intracranial hemorrhage (SICH). Whether low-dose tPA can effectively reduce SICH and has the same efficacy as standard-dose tPA is still controversial. We searched for English clinical trials published before March, 2017on the comparison of the efficacy and safety between low and standard dose of tPA in the treatment of AIS using MEDLINE, Embase, and Cochrane Library. The modified Rankin scale (mRS) score was used as the primary efficacy outcome. The mRS1 corresponded to 0-1, whereas mRS2 corresponded to 0-2. The SICH and mortality were adopted as primary safety outcomes. Twelve high-quality studies were selected, including 7686 patients (low-dose: 2888, standard-dose: 4798). With no statistical heterogeneity, the fixed effects model was adopted in the analysis. Similarly to standard doses, low-dose tPA improved the mRS scores (mRS1: odds ratio [OR] = .92, 95% confidence interval [CI] .84-1.02; P = .12; mRS2: OR = .97, 95% CI .88-1.08; P = .57). Compared with standard-dose tPA, low-dose tPA reduced the incidence of SICH (by National Institute of Neurological Disorders and Stroke [NINDS] definition: OR = .71, 95% CI .57-0.89; P = .003; by Safe Implementation of Thrombolysis in Stroke Monitoring Study [SITS-MOST] definition: OR = .64, 95% CI .42-0.99; P = .04), while both reduced mortality (OR = .87, 95% CI .74-1.02; P = .08). Low-dose tPA is comparable to standard-dose tPA in improving the neurologic function and reducing mortality in AIS patients. Moreover, low-dose tPA can reduce the incidence of SICH compared with standard-dose tPA. Therefore, low-dose tPA is highly recommended in AIS patients. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.
Triheptanoin improves brain energy metabolism in patients with Huntington disease
Adanyeguh, Isaac Mawusi; Rinaldi, Daisy; Henry, Pierre-Gilles; Caillet, Samantha; Valabregue, Romain; Durr, Alexandra
2015-01-01
Objective: Based on our previous work in Huntington disease (HD) showing improved energy metabolism in muscle by providing substrates to the Krebs cycle, we wished to obtain a proof-of-concept of the therapeutic benefit of triheptanoin using a functional biomarker of brain energy metabolism validated in HD. Methods: We performed an open-label study using 31P brain magnetic resonance spectroscopy (MRS) to measure the levels of phosphocreatine (PCr) and inorganic phosphate (Pi) before (rest), during (activation), and after (recovery) a visual stimulus. We performed 31P brain MRS in 10 patients at an early stage of HD and 13 controls. Patients with HD were then treated for 1 month with triheptanoin after which they returned for follow-up including 31P brain MRS scan. Results: At baseline, we confirmed an increase in Pi/PCr ratio during brain activation in controls—reflecting increased adenosine triphosphate synthesis—followed by a return to baseline levels during recovery (p = 0.013). In patients with HD, we validated the existence of an abnormal brain energy profile as previously reported. After 1 month, this profile remained abnormal in patients with HD who did not receive treatment. Conversely, the MRS profile was improved in patients with HD treated with triheptanoin for 1 month with the restoration of an increased Pi/PCr ratio during visual stimulation (p = 0.005). Conclusion: This study suggests that triheptanoin is able to correct the bioenergetic profile in the brain of patients with HD at an early stage of the disease. Classification of evidence: This study provides Class III evidence that, for patients with HD, treatment with triheptanoin for 1 month restores an increased MRS Pi/PCr ratio during visual stimulation. PMID:25568297
NASA Astrophysics Data System (ADS)
Raylman, Raymond R.; Majewski, Stan; Velan, S. Sendhil; Lemieux, Susan; Kross, Brian; Popov, Vladimir; Smith, Mark F.; Weisenberger, Andrew G.
2007-06-01
Multi-modality imaging (such as PET-CT) is rapidly becoming a valuable tool in the diagnosis of disease and in the development of new drugs. Functional images produced with PET, fused with anatomical images created by MRI, allow the correlation of form with function. Perhaps more exciting than the combination of anatomical MRI with PET, is the melding of PET with MR spectroscopy (MRS). Thus, two aspects of physiology could be combined in novel ways to produce new insights into the physiology of normal and pathological processes. Our team is developing a system to acquire MRI images and MRS spectra, and PET images contemporaneously. The prototype MR-compatible PET system consists of two opposed detector heads (appropriate in size for small animal imaging), operating in coincidence mode with an active field-of-view of ˜14 cm in diameter. Each detector consists of an array of LSO detector elements coupled through a 2-m long fiber optic light guide to a single position-sensitive photomultiplier tube. The use of light guides allows these magnetic field-sensitive elements of the PET imager to be positioned outside the strong magnetic field of our 3T MRI scanner. The PET scanner imager was integrated with a 12-cm diameter, 12-leg custom, birdcage coil. Simultaneous MRS spectra and PET images were successfully acquired from a multi-modality phantom consisting of a sphere filled with 17 brain relevant substances and a positron-emitting radionuclide. There were no significant changes in MRI or PET scanner performance when both were present in the MRI magnet bore. This successful initial test demonstrates the potential for using such a multi-modality to obtain complementary MRS and PET data.
Ashraf, Rabia; Shah, Nagendra P
2011-10-03
Yoghurt is increasingly being used as a carrier of probiotic bacteria for their potential health benefits. To meet with a recommended level of ≥10(6) viable cells/g of a product, assessment of viability of probiotic bacteria in market preparations is crucial. This requires a working method for selective enumeration of these probiotic bacteria and lactic acid bacteria in yoghurt such as Streptococcus thermophilus, Lactobacillus delbrueckii subsp. bulgaricus, Lb. acidophilus, Lb. casei and Bifidobacterium. This chapter presents an overview of media that could be used for differential and selective enumerations of yoghurt bacteria. De Man Rogosa Sharpe agar containing fructose (MRSF), MRS agar pH 5.2 (MRS 5.2), reinforced clostridial prussian blue agar at pH 5.0 (RCPB 5.0) or reinforced clostridial agar at pH 5.3 (RCA 5.3) are suitable for enumeration of Lb. delbrueckii subsp. bulgaricus when the incubation is carried out at 45°C for 72h. S. thermophilus (ST) agar and M17 are recommended for selective enumeration of S. thermophilus. Selective enumeration of Lb. acidophilus in mixed culture could be made in Rogosa agar added with 5-bromo-4-chloro-3-indolyl-β-d-glucopyranoside (X-Glu) or MRS containing maltose (MRSM) and incubation in a 20% CO2 atmosphere. Lb. casei could be selectively enumerated on specially formulated Lb. casei (LC) agar from products containing yoghurt starter bacteria (S. thermophilus and Lb. delbrueckii subsp. bulgaricus), Lb. acidophilus, Bifidobacterium spp. and Lb. casei. Bifidobacterium could be enumerated on MRS agar supplemented with nalidixic acid, paromomycin, neomycin sulphate and lithium chloride (MRS-NPNL) under anaerobic incubation at 37°C for 72h. Copyright © 2011. Published by Elsevier B.V.
Le, Thuy-Anh; Chen, Joshua; Changchien, Christopher; Peterson, Michael R; Kono, Yuko; Patton, Heather; Cohen, Benjamin L; Brenner, David; Sirlin, Claude; Loomba, Rohit
2012-01-01
Bile acid sequestrants (BAS) lower plasma low density lipoprotein levels and improve glycemic control. Colestimide, a BAS, has been claimed by computed tomography to reduce liver fat. Therefore, we examined the efficacy of colesevelam, a potent BAS, to decrease liver fat in patients with biopsy-proven nonalcoholic steatohepatitis (NASH). Liver fat was measured by a novel magnetic resonance imaging (MRI) technique, the proton-density-fat-fraction (PDFF), as well as by conventional MR spectroscopy (MRS). Fifty patients with biopsy-proven NASH were randomly assigned to either colesevelam 3.75 g/day orally or placebo for 24 weeks. The primary outcome was change in liver fat as measured by MRI-PDFF in colocalized regions of interest within each of the nine liver segments. Compared with placebo, colesevelam increased liver fat by MRI-PDFF in all nine segments of the liver with a mean difference of 5.6% (P = 0.002). We cross-validated the MRI-PDFF-determined fat content with that assessed by colocalized MRS; the latter showed a mean difference of 4.9% (P = 0.014) in liver fat between the colesevelam and the placebo arms. MRI-PDFF correlated strongly with MRS-determined hepatic fat content (r2 = 0.96, P < 0.0001). Liver biopsy assessment of steatosis, cellular injury, and lobular inflammation did not detect any effect of treatment. Conclusion: Colesevelam increases liver fat in patients with NASH as assessed by MRI as well as MRS without significant changes seen on histology. Thus, MRI and MRS may be better than histology to detect longitudinal changes in hepatic fat in NASH. Underlying mechanisms and whether the small MR-detected increase in liver fat has clinical consequences is not known. (Hepatology 2012;56:922–932) PMID:22431131
Gallagher, Timothy M.; Sheldon, Nathan D.; Mauk, Jeffrey L.; Petersen, Sierra V.; Gueneli, Nur; Brocks, Jochen J.
2017-01-01
The Midcontinent Rift System (MRS) is a Late Mesoproterozoic (∼1.1 Ga) sequence of volcanic and sedimentary rocks exposed in the Lake Superior Region of North America. The MRS continues to be the focus of much research due to its economic mineral deposits as well as its archive of Precambrian life and tectonic processes. In order to constrain the post-depositional thermal history of the MRS, samples were analyzed for carbonate clumped isotope composition and organic thermal maturity. Clumped isotope values from sedimentary/early-diagenetic samples were partially reset during burial to temperatures between 68 and 75 °C. Solid-state reordering models indicate that maximum burial temperatures of 125–155 °C would reset the clumped isotope values to the observed temperature range prior to the onset of regional cooling and uplift. Clumped isotope results from late-stage veins in the White Pine Mine encompass a greater temperature range (49–116 °C), indicative of spatially variable hydrothermal activity and vein emplacement after burial temperatures fell below 100 °C during regional cooling and uplift. Clumped isotope and organic thermal maturity data do not indicate significant spatial differences in thermal history along the MRS. Observed variability in bulk organic matter composition and biomarker indices are therefore more likely a result of shifts in primary productivity or early-degradation processes. These results demonstrate that the MRS experienced a spatially consistent, relatively mild thermal history (125–155 °C) and is therefore a valuable archive for understanding the Late Mesoproterozoic environment.
Walecki, Jerzy; Barcikowska, Maria; Ćwikła, Jarosław B; Gabryelewicz, Tomasz
2011-12-01
Purpose of study was evaluation of regional metabolic disorders using 1H MRS in patients with MCI, as a predictor of clinical conversion to dementia based on clinical follow-up. The study group consisted of 31 subjects with diagnosis of MCI based on criteria the Mayo Clinic Group. ¹H MRS was performed with a single-voxel method using PRESS sequence. The volume of interest (VOI) was located in the hippocampal formation and posterior part of the cingulated gyrus. Patients had annual clinical control at least twice. At the beginning, 9 had amnestic MCI and the others had multidomain MCI. During follow-up (median 3 yrs) 8 subjects had stable disease (SD), 13 had disease progression (DP) and 10 develop Alzheimer disease (AD). Baseline metabolic ratios (1H MRS) between 3 groups indicated significant difference (P < 0.05) in left frontal lobe in mI/H20 ratio, between patients with SD (0.27) and DP. In comparing the groups with DP and AD, a significant difference in NAA/Cr (1.77 vs. 1.43) was found. A significant difference within left temporal external lobes was found between SD and DP in NAA/H2O ratio (0.55 vs. 0.51). An additional significant difference within medial temporal lobe was found between DP and AD in Glx/H2O ratio (0.44 vs. 0.34) on the right side. 1H MRS seems to be sensitive method allows prediction of which patients are liable to progress from MCI to AD. Combined with other biomarkers of disease staging, it is an important approach in the preclinical AD diagnosis, as well as the assessment of dementia progression.
Talebi, Mahnaz; Ghertasi, Mohammad; Taheraghdam, Aliakbar; Andalib, Sasan; Sharifipour, Ehsan
2014-01-01
Background: Gender difference has been reported in stroke risk factors and disease history. The aim of this study was to compare risk factors and the severity of ischemic stroke based upon modified Rankin Scale (mRS) and hospital mortality between two genders. Methods: In a cross-sectional study, 341 patients (44% males and 56% females with a mean age of 68.94 ± 12.74 years) with ischemic stroke, who were hospitalized in the neurology wards of two referral university hospital of North-West Iran (Imam Reza and Razi Hospitals), from the beginning to the end of 2011 were selected and assessed. Gender difference in terms of demographic findings, vascular risk factors, 7th day mRS, and hospital mortality (during admission) were evaluated. Results: In 2.6% of cases, mRS was found to be less than 2 (favorable) and in 97.4% of cases; mRS was 2-5 (with disability). No significant difference in ischemic stroke severity based on mRS was observed between two genders. There was a significant difference in the rate of hypertension (females = 72.3%, males = 59.3%, P = 0.010), diabetes (females = 28.8%, males = 18.7%, P = 0.030), smoking (females = 6.3%, males = 35.3%, P < 0.001). No significant difference was seen in other risk factors between two genders. There was no significant difference in the mortality rate, which constituted 8.9% and 4.7% in females and males respectively (P = 0.140). Conclusion: The evidence from the present study suggests that despite the existence of some difference between risk-factors in two genders, there was no difference in terms of ischemic stroke severity and mortality rate between two genders. PMID:25632333
Talebi, Mahnaz; Ghertasi, Mohammad; Taheraghdam, Aliakbar; Andalib, Sasan; Sharifipour, Ehsan
2014-10-06
Gender difference has been reported in stroke risk factors and disease history. The aim of this study was to compare risk factors and the severity of ischemic stroke based upon modified Rankin Scale (mRS) and hospital mortality between two genders. In a cross-sectional study, 341 patients (44% males and 56% females with a mean age of 68.94 ± 12.74 years) with ischemic stroke, who were hospitalized in the neurology wards of two referral university hospital of North-West Iran (Imam Reza and Razi Hospitals), from the beginning to the end of 2011 were selected and assessed. Gender difference in terms of demographic findings, vascular risk factors, 7(th) day mRS, and hospital mortality (during admission) were evaluated. In 2.6% of cases, mRS was found to be less than 2 (favorable) and in 97.4% of cases; mRS was 2-5 (with disability). No significant difference in ischemic stroke severity based on mRS was observed between two genders. There was a significant difference in the rate of hypertension (females = 72.3%, males = 59.3%, P = 0.010), diabetes (females = 28.8%, males = 18.7%, P = 0.030), smoking (females = 6.3%, males = 35.3%, P < 0.001). No significant difference was seen in other risk factors between two genders. There was no significant difference in the mortality rate, which constituted 8.9% and 4.7% in females and males respectively (P = 0.140). The evidence from the present study suggests that despite the existence of some difference between risk-factors in two genders, there was no difference in terms of ischemic stroke severity and mortality rate between two genders.
Singh, Kavita; Trivedi, Richa; Verma, Ajay; D'souza, Maria M; Koundal, Sunil; Rana, Poonam; Baishya, Bikash; Khushu, Subash
2017-10-01
Traumatic brain injury (TBI) has been shown to affect hippocampus-associated learning, memory and higher cognitive functions, which may be a consequence of metabolic alterations. Hippocampus-associated disorders may vary depending on the severity of injury [mild TBI (miTBI) and moderate TBI (moTBI)] and time since injury. The underlying hippocampal metabolic irregularities may provide an insight into the pathological process following TBI. In this study, in vivo and in vitro proton magnetic resonance spectroscopy ( 1 H-MRS) data were acquired from the hippocampus region of controls and TBI groups (miTBI and moTBI) at D0 (pre-injury), 4 h, Day 1 and Day 5 post-injury (PI). In vitro MRS results indicated trauma-induced changes in both miTBI and moTBI; however, in vivo MRS showed metabolic alterations in moTBI only. miTBI and moTBI showed elevated levels of osmolytes indicating injury-induced edema. Altered levels of citric acid cycle intermediates, glutamine/glutamate and amino acid metabolism indicated injury-induced aberrant bioenergetics, excitotoxicity and oxidative stress. An overall similar pattern of pathological process was observed in both miTBI and moTBI, with the distinction of depleted N-acetylaspartate levels (indicating neuronal loss) at 4 h and Day 1 and enhanced lactate production (indicating heightened energy depletion leading to the commencement of the anaerobic pathway) at Day 5 in moTBI. To the best of our knowledge, this is the first study to investigate the hippocampus metabolic profile in miTBI and moTBI simultaneously using in vivo and in vitro MRS. Copyright © 2017 John Wiley & Sons, Ltd.
Sievert, Christine; Richter, Henning; Beckmann, Katrin; Kircher, Patrick R; Carrera, Ines
2017-01-01
In vivo diagnosis of tick-borne encephalitis is difficult due to high seroprevalence and rapid viral clearance, limiting detection of antibodies in blood and cerebrospinal fluid. Magnetic resonance imaging (MRI) characteristics of tick-borne encephalitis have been reported, however MRI studies can also be negative despite the presence of neurologic signs. Magnetic resonance spectroscopy ( 1 H MRS) is an imaging method that provides additional information about the metabolic characteristics of brain tissues. The purpose of this retrospective cross-sectional study was to describe brain metabolites using short echo time single-voxel 1 H MRS in dogs with confirmed tick-borne encephalitis and compare them with healthy dogs. Inclusion criteria for the affected dogs were neurological symptoms suggestive of tick-borne encephalitis, previous endemic stay and tick-bite, diagnostic quality brain MRI and 1 H MRS studies, and positive antibody titers or confirmation of tick-borne encephalitis with necropsy. Control dogs were 10, clinically normal beagles that had been used in a previous study. A total of six affected dogs met inclusion criteria. All dogs affected with tick-borne encephalitis had 1 H MRS metabolite concentration alterations versus control dogs. These changes included mild to moderate decreases in N-acetyl aspartate and creatine peaks, and mild increases in glutamate/glutamine peaks. No lactate or lipid signal was detected in any dog. Myoinositol and choline signals did not differ between affected and control dogs. In conclusion, findings supported the use of 1 H MRS as an adjunctive imaging method for dogs with suspected tick-borne encephalitis and inconclusive conventional MRI findings. © 2016 American College of Veterinary Radiology.
Enhancement of bile resistance in Lactobacillus plantarum strains by soy lecithin.
Hu, B; Tian, F; Wang, G; Zhang, Q; Zhao, J; Zhang, H; Chen, W
2015-07-01
This study evaluated the effect of soy lecithin on the bile resistance of Lactobacillus plantarum. Six strains were cultured in MRS broth supplemented with soy lecithin at different concentrations. The strains incubated in MRS broth with 1·0% soy lecithin showed no inhibitory effect on cell growth. After culturing in MRS broth with 0·2-1·0% soy lecithin, the survival rate of harvested cells increased significantly (P < 0·05) in the 0·3% bile challenge compared with the no added soy lecithin group. The cells incubated with 0·6% soy lecithin were able to grow in an MRS broth with a higher bile salt content. The surface hydrophobicity and cell leakage in the bile challenge were assessed to reveal the physical changes caused by the addition of soy lecithin. The cell surface hydrophobicity was enhanced and the membrane integrity in the bile challenge increased after culturing with soy lecithin. A shift in the fatty acid composition was also observed, illustrating the cell membrane change in the soy lecithin culture. In this study, we report for the first time the beneficial effect of adding soy lecithin to an MRS broth on subsequent bile tolerance of Lactobacillus plantarum. Soy lecithin had no inhibitory effect on strain viability but significantly enhanced bile resistance. Surface hydrophobicity and cell integrity increased in strains cultured with soy lecithin. The observed shift in the cell fatty acid composition indicated changes to the cell membrane. As soy lecithin is safe for use in the food industry, its protective effects can be harnessed for the development of bile-sensitive strains with health-benefit functions for use in probiotic products. © 2015 The Society for Applied Microbiology.
Clinical features of subarachnoid hemorrhage in patients with positive cancer history.
Shibahara, Ichiyo; Watanabe, Takashi; Ezura, Masayuki; Inoue, Takashi; Fujimura, Miki; Kimura, Naoto; Inoue, Tomoo; Suzuki, Ichiro; Nishino, Akiko; Nishimura, Shinjitsu; Uenohara, Hiroshi; Tominaga, Teiji
2016-05-01
Advances in cancer treatment have dramatically increased long-term survivors. Prolonged survival increases comorbidity risk, but there is a paucity of studies on how cancer history alters clinical outcomes from subsequent diseases. This study aims to investigate whether positive cancer history influences clinical outcome following subarachnoid hemorrhage (SAH). We retrospectively reviewed consecutive SAH patients admitted between January 2008 and March 2014. Medical histories, known SAH risk factors, and outcome were compared between SAH patients with and without cancer history. Out of the 498 SAH patients, 55 cases had cancer history, 438 cases had no cancer history and 5 cases had an unknown cancer history. Compared with SAH patients without cancer history, those with cancer history had poorer Hunt & Hess grade at SAH presentation (P = 0.021), and poorer modified Rankin Scale (mRS) score at discharge (P < 0.001). After adjustment for age, sex, modified Fisher, previous SAH, history of hypertension, current smoking status, and current alcohol consumption, positive cancer history remained an independent risk factor for poorer mRS0-6 [odds ratio (OR) = 2.25, 95 % confidence interval (CI) 1.28-3.94] and mRS6 (OR = 2.74, 95 % CI 1.40-5.37). Furthermore, stratified analysis by Hunt & Hess grade adjusted by age, sex, and modified Fisher scale, OR of poorer mRS0-6 was 2.12 (95 % CI 0.89-5.05) and OR of mRS6 was 3.68 (95 % CI 1.35-10.04). After adjustment of patients for demographic factors, classical risk factors for SAH and Hunt & Hess grade, previous cancer history is a risk factor for the poor functional outcome of SAH.
Yoo, Chi-Hyeon; Song, Kyu-Ho; Lim, Song-I; Woo, Dong-Cheol; Choe, Bo-Young
2018-05-15
Recent evidence suggests that the glutamate system plays an important role in the pathogenesis of major depressive disorder (MDD). The aim of this study was to investigate the effects of light deprivation (LD) in the prefrontal cortex (PFC) of animals with depression-like behavior, targeting the glutamate system, using in vivo proton magnetic resonance spectroscopy ( 1 H MRS). Male Sprague-Dawley rats were housed in constant darkness for six weeks (n = 12; LD group), while controls (n = 8) were housed under normal light cycles. The animals were assessed with forced swim tests. Point-resolved spectroscopy was used to quantify metabolite levels in the PFC. To substantiate the validity of the use of in vivo 1 H MRS in this study, the spectra obtained in the in vivo 1 H MRS, parametrically matched spectral simulation, and in vitro experiments were analyzed. The results of the spectral analyses showed that the quantification of glutamate and glutamine was not significantly affected by spectral overlaps. Thus, these results suggested that in vivo 1 H MRS can be used to reliably investigate the glutamate system. The results of the forced swim test showed LD-induced behavioral despairs in the animals. The levels of glutamate, myo-inositol, phosphocreatine, and total creatine were found significantly (p < 0.010) increased in the PFC of the LD animals compared with the controls. These results suggested that the LD-induced metabolic changes were consistent with the previous findings in patients with MDD and that short-echo-time in vivo 1 H MRS can be used to effectively measure depression-induced alterations in glutamate systems. Copyright © 2018 Elsevier B.V. All rights reserved.
Blüml, Stefan; Margol, Ashley S; Sposto, Richard; Kennedy, Rebekah J; Robison, Nathan J; Vali, Marzieh; Hung, Long T; Muthugounder, Sakunthala; Finlay, Jonathan L; Erdreich-Epstein, Anat; Gilles, Floyd H; Judkins, Alexander R; Krieger, Mark D; Dhall, Girish; Nelson, Marvin D; Asgharzadeh, Shahab
2016-01-01
Medulloblastomas in children can be categorized into 4 molecular subgroups with differing clinical characteristics, such that subgroup determination aids in prognostication and risk-adaptive treatment strategies. Magnetic resonance spectroscopy (MRS) is a widely available, noninvasive tool that is used to determine the metabolic characteristics of tumors and provide diagnostic information without the need for tumor tissue. In this study, we investigated the hypothesis that metabolite concentrations measured by MRS would differ between molecular subgroups of medulloblastoma and allow accurate subgroup determination. MRS was used to measure metabolites in medulloblastomas across molecular subgroups (SHH = 12, Groups 3/4 = 17, WNT = 1). Levels of 14 metabolites were analyzed to determine those that were the most discriminant for medulloblastoma subgroups in order to construct a multivariable classifier for distinguishing between combined Group 3/4 and SHH tumors. Medulloblastomas across molecular subgroups revealed distinct spectral features. Group 3 and Group 4 tumors demonstrated metabolic profiles with readily detectable taurine, lower levels of lipids, and high levels of creatine. SHH tumors showed prominent choline and lipid with low levels of creatine and little or no evidence of taurine. A 5-metabolite subgroup classifier inclusive of creatine, myo-inositol, taurine, aspartate, and lipid 13a was developed that could discriminate between Group 3/4 and SHH medulloblastomas with excellent accuracy (cross-validated area under the curve [AUC] = 0.88). The data show that medulloblastomas of Group 3/4 differ metabolically as measured using MRS when compared with SHH molecular subgroups. MRS is a useful and accurate tool to determine medulloblastoma molecular subgroups. © The Author(s) 2015. Published by Oxford University Press on behalf of the Society for Neuro-Oncology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
VizieR Online Data Catalog: Friends-of-friends galaxy group finder (Tempel+, 2016)
NASA Astrophysics Data System (ADS)
Tempel, E.; Kipper, R.; Tamm, A.; Gramann, M.; Einasto, M.; Sepp, T.; Tuvikene, T.
2016-01-01
To delineate galaxy groups in the local Universe, we used galaxy data from the extragalactic distance database (EDD2; Tully et al., 2009AJ....138..323T). The sample encompasses three datasets. As the main source, we used the Two Micron All Sky Survey (Skrutskie et al. 2006AJ....131.1163S, Cat. VII/233) Redshift Survey (2MRS) galaxies brighter than 11.75 mag in the Ks band (for a description of the catalogue, see Huchra et al., 2012, Cat. J/ApJS/199/26). We only used galaxies that are securely off the Galactic plane: Galactic latitude |b|>5°. Since the galaxy sample becomes extremely sparse farther away, we only used galaxies with a cosmic microwave background (CMB) corrected redshift z=0...0.1 (up to 430Mpc). This selection restricts our 2MRS sample to 43480 galaxies. For our analysis, we complemented the main 2MRS sample with two other sources. From the CosmicFlows-2 survey that contains 8198 galaxies with redshift-independent distance estimates (CF2; Tully et al., 2013, Cat. J/AJ/146/86), we added 3627 (of these, 2799 galaxies do not have a measured Ks magnitude). In addition, we made use of the 2M++ catalogue Lavaux & Hudson (2011, Cat. J/MNRAS/416/2840), which combines elements from the 2MRS, the 6DF Galaxy Survey (Jones et al. 2009MNRAS.399..683J, Cat. VII/259), and the Sloan Digital Sky Survey (York et al., 2000AJ....120.1579Y). Of the 64745 galaxies of the 2M++, we added 31271 galaxies down to Ks<12.54, which extends the sample well beyond the 2MRS magnitude limit. Our final galaxy dataset includes 78378 galaxies. (4 data files).
Zhang, Hong-Xi; Fu, Jun-Fen; Lai, Can; Tian, Feng-Yu; Su, Xiao-Li; Huang, Ke
2018-04-30
To determine the feasibility of balanced steady-state free precession (b-SSFP) imaging for measuring hepatic steatosis in obese children and adolescents, using proton magnetic resonance spectroscopy ( 1 H MRS) as reference standard. 182 obese Chinese paediatric patients underwent conventional T1-weighted dual echo MRI, 1 H MRS and b-SSFP imaging for non-invasive assessment of hepatic steatosis. There was a strong positive correlation between liver fat fraction (FF) on T1-weighted dual echo MRI and 1 H MRS-determined liver fat content (LFC) (r = 0.964, p < .001), and a strong negative correlation between the ratio of liver signal intensity (SI) to spleen SI (L/S) on b-SSFP and LFC (r = -0.896, p < .001). ROC curve analysis based on a diagnostic threshold of 1 H MRS-determined LFC >50 mg/g (>5 % by wet weight) showed areas under the curves for FF and L/S at 0.989 (0.976-1.000) and 0.926 (0.888-0.964), respectively. Optimal FF and L/S cut-off values identified patients with hepatic steatosis with 97.9 % and 86.5 % sensitivity and 93.4 % and 93.4 % specificity, respectively. Following further validation, b-SSFP at 1.5T has potential as a feasible technique for evaluation of hepatic steatosis in obese paediatric patients with limited breath-holding capacity. • L/S on b-SSFP images closely correlated with 1 H MRS-determined LFC. • b-SSFP has high diagnostic accuracy for hepatic steatosis in obese children. • 100% of obese paediatric subjects are imaged successfully using b-SSFP sequence. • b-SSFP has potential to evaluate hepatic steatosis in children with poor breath-hold.
Bawden, S J; Stephenson, M C; Ciampi, E; Hunter, K; Marciani, L; Macdonald, I A; Aithal, G P; Morris, P G; Gowland, P A
2016-06-01
Impaired homeostasis of hepatic ATP has been associated with NAFLD. An intravenous fructose infusion has been shown to be an effective challenge to monitor the depletion and subsequent recovery of hepatic ATP reserves using (31)P MRS. The purpose of this study was to evaluate the effects of an oral rather than intravenous fructose challenge on hepatic ATP reserves in healthy subjects. Self-reported healthy males were recruited. Following an overnight fast, baseline liver glycogen and lipid levels were measured using Magnetic Resonance Spectroscopy (MRS). Immediately after consuming a 500 ml 75 g fructose drink (1275 kJ) subjects were scanned continuously for 90 min to acquire dynamic (31)P MRS measurements of liver ATP reserves. A significant effect on ATP reserves was observed across the time course (P < 0.05). Mean ATP levels reached a minimum at 50 min which was markedly lower than baseline (80 ± 17% baseline, P < 0.05). Subsequently, mean values tended to rise but did not reach statistical significance above minimum. The time to minimum ATP levels across subjects was negatively correlated with BMI (R(2) = 0.74, P < 0.005). Rates of ATP recovery were not significantly correlated with BMI or liver fat levels, but were negatively correlated with baseline glycogen levels (R(2) = 0.7, P < 0.05). Depletion of ATP reserves can be measured non-invasively following an oral fructose challenge using (31)P MRS. BMI is the best predictor of postprandial ATP homeostasis following fructose consumption. Copyright © 2015 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
Petritsch, B; Köstler, H; Weng, A M; Horn, M; Gassenmaier, T; Kunz, A S; Weidemann, F; Wanner, C; Bley, T A; Beer, M
2016-10-28
Fabry disease is characterized by a progressive deposition of sphingolipids in different organ systems, whereby cardiac involvement leads to death. We hypothesize that lysosomal storage of sphingolipids in the heart as occurring in Fabry disease does not reflect in higher cardiac lipid concentrations detectable by 1 H magnetic resonance spectroscopy (MRS) at 3 Tesla. Myocardial lipid content was quantified in vivo by 1 H-MRS in 30 patients (12 male, 18 female; 18 patients treated with enzyme replacement therapy) with genetically proven Fabry disease and in 30 healthy controls. The study protocol combined 1 H-MRS with cardiac cine imaging and LGE MRI in a single examination. Myocardial lipid content was not significantly elevated in Fabry disease (p = 0.225). Left ventricular (LV) mass was significantly higher in patients suffering from Fabry disease compared to controls (p = 0.019). Comparison of patients without signs of myocardial fibrosis in MRI (LGE negative; n = 12) to patients with signs of fibrosis (LGE positive; n = 18) revealed similar myocardial lipid content in both groups (p > 0.05), while the latter showed a trend towards elevated LV mass (p = 0.076). This study demonstrates the potential of lipid metabolic investigation embedded in a comprehensive examination of cardiac morphology and function in Fabry disease. There was no evidence that lysosomal storage of sphingolipids influences cardiac lipid content as measured by 1 H-MRS. Finally, the authors share the opinion that a comprehensive cardiac examination including three subsections (LGE; 1 H-MRS; T 1 mapping), could hold the highest potential for the final assessment of early and late myocardial changes in Fabry disease.
Chouinard, Virginie-Anne; Kim, Sang-Young; Valeri, Linda; Yuksel, Cagri; Ryan, Kyle P; Chouinard, Guy; Cohen, Bruce M; Du, Fei; Öngür, Dost
2017-09-01
Brain bioenergetic anomalies and redox dysregulation have been implicated in the pathophysiology of psychotic disorders. The present study examined brain energy-related metabolites and the balance between nicotinamide adenine dinucleotide metabolites (oxidized NAD+ and reduced NADH) using 31 P-magnetic resonance spectroscopy ( 31 P-MRS) in unaffected siblings, compared to first episode psychosis (FEP) patients and healthy controls. 21 unaffected siblings, 32 FEP patients (including schizophrenia spectrum and affective psychoses), and 21 controls underwent 31 P-MRS in the frontal lobe (6×6×4cm 3 ) on a 4T MR scanner, using custom-designed dual-tuned surface coil with outer volume suppression. Brain parenchymal pH and steady-state metabolite ratios of high energy phosphate compounds were measured. NAD+ and NADH levels were determined using a 31 P-MRS fitting algorithm. 13 unaffected sibling-patient pairs were related; other patients and siblings were unrelated. ANCOVA analyses were used to examine 31 P-MRS measures, with age and gender as covariates. The phosphocreatine/adenosine triphosphate ratio was significantly reduced in both unaffected siblings and FEP patients, compared to controls. NAD+/NADH ratio was significantly reduced in patients compared to siblings and controls, with siblings showing a reduction in NAD+/NADH compared to controls that was not statistically significant. Compared to patients and controls, siblings showed significantly reduced levels of NAD+. Siblings did not differ from patients or controls on brain pH. Our results indicate that unaffected siblings show some, but not all the same abnormalities in brain energy metabolites and redox state as FEP patients. Thus, 31 P-MRS studies may identify factors related both to risk and expression of psychosis. Copyright © 2017 Elsevier B.V. All rights reserved.
2010-01-01
Background Proton Magnetic Resonance (MR) Spectroscopy (MRS) is a widely available technique for those clinical centres equipped with MR scanners. Unlike the rest of MR-based techniques, MRS yields not images but spectra of metabolites in the tissues. In pathological situations, the MRS profile changes and this has been particularly described for brain tumours. However, radiologists are frequently not familiar to the interpretation of MRS data and for this reason, the usefulness of decision-support systems (DSS) in MRS data analysis has been explored. Results This work presents the INTERPRET DSS version 3.0, analysing the improvements made from its first release in 2002. Version 3.0 is aimed to be a program that 1st, can be easily used with any new case from any MR scanner manufacturer and 2nd, improves the initial analysis capabilities of the first version. The main improvements are an embedded database, user accounts, more diagnostic discrimination capabilities and the possibility to analyse data acquired under additional data acquisition conditions. Other improvements include a customisable graphical user interface (GUI). Most diagnostic problems included have been addressed through a pattern-recognition based approach, in which classifiers based on linear discriminant analysis (LDA) were trained and tested. Conclusions The INTERPRET DSS 3.0 allows radiologists, medical physicists, biochemists or, generally speaking, any person with a minimum knowledge of what an MR spectrum is, to enter their own SV raw data, acquired at 1.5 T, and to analyse them. The system is expected to help in the categorisation of MR Spectra from abnormal brain masses. PMID:21114820
Utine, G E; Akpınar, B; Arslan, U; Kiper, P Ö Ş; Volkan-Salancı, B; Alanay, Y; Aktaş, D; Haliloğlu, G; Oğuz, K K; Boduroğlu, K; Alikaşifoğlu, M
2014-01-01
Fragile X syndrome (FXS) is the most common hereditary disorder of intellectual disability. Cognitive deficits involve executive function, attention, learning and memory. Advanced neuroimaging techniques are available, and (1)H magnetic resonance spectroscopy (MRS) can be used as a complementary method to MR imaging to understand disease processes in brain, by in vivo demonstration of brain metabolites. MRS was performed in 13 male patients with FXS full mutation, and 13 age- and sex-matched healthy controls. FXS diagnosis was based on clinical evaluation, followed by detection of FMR1 full mutation. Axial T2 TSE, sagittal T1 SE and coronal 3D MPRAGE images were obtained for both morphological imaging and voxel localization. Following evaluation of conventional images, multivoxel MRS (CSI) through supraventricular white matter and single voxel MRS (svs) with an intermediate echo time (TE:135 ms) from the cerebellar vermis were performed. Choline/Creatine (Cho/Cr), N-acetyl aspartate/Creatine (NAA/Cr), and Choline/N-acetyl aspartate (Cho/NAA) ratios were examined at right frontal (RF), left frontal (LF), right parietal (RP), left parietal (LP), and cerebellar vermian (C) white matter. Statistical analyses were done using t-test and Mann-Whitney U tests. A statistically significant difference was observed in RP Cho/NAA ratio (cell membrane marker/neuroaxonal marker), FXS patients having lower levels than controls (P = 0.016). The results should be evaluated cautiously in parallel to consequences in brain metabolism leading to alterations in neurotransmitter levels, osmoregulation, energy metabolism and oxidative stress response described in animal models. MRS may serve to define a metabolic signature and biomarkers associated with FXS. © 2013 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Olliverre, Nathan; Asad, Muhammad; Yang, Guang; Howe, Franklyn; Slabaugh, Gregory
2017-03-01
Multi-Voxel Magnetic Resonance Spectroscopy (MV-MRS) provides an important and insightful technique for the examination of the chemical composition of brain tissue, making it an attractive medical imaging modality for the examination of brain tumours. MRS, however, is affected by the issue of the Partial Volume Effect (PVE), where the signals of multiple tissue types can be found within a single voxel and provides an obstacle to the interpretation of the data. The PVE results from the low resolution achieved in MV-MRS images relating to the signal to noise ratio (SNR). To counteract PVE, this paper proposes a novel Pairwise Mixture Model (PMM), that extends a recently reported Signal Mixture Model (SMM) for representing the MV-MRS signal as normal, low or high grade tissue types. Inspired by Conditional Random Field (CRF) and its continuous variant the PMM incorporates the surrounding voxel neighbourhood into an optimisation problem, the solution of which provides an estimation to a set of coefficients. The values of the estimated coefficients represents the amount of each tissue type (normal, low or high) found within a voxel. These coefficients can then be visualised as a nosological rendering using a coloured grid representing the MV-MRS image overlaid on top of a structural image, such as a Magnetic Resonance Image (MRI). Experimental results show an accuracy of 92.69% in classifying patient tumours as either low or high grade compared against the histopathology for each patient. Compared to 91.96% achieved by the SMM, the proposed PMM method demonstrates the importance of incorporating spatial coherence into the estimation as well as its potential clinical usage.
Muscle MRS detects elevated PDE/ATP ratios prior to fatty infiltration in Becker muscular dystrophy.
Wokke, B H; Hooijmans, M T; van den Bergen, J C; Webb, A G; Verschuuren, J J; Kan, H E
2014-11-01
Becker muscular dystrophy (BMD) is characterized by progressive muscle weakness. Muscles show structural changes (fatty infiltration, fibrosis) and metabolic changes, both of which can be assessed using MRI and MRS. It is unknown at what stage of the disease process metabolic changes arise and how this might vary for different metabolites. In this study we assessed metabolic changes in skeletal muscles of Becker patients, both with and without fatty infiltration, quantified via Dixon MRI and (31) P MRS. MRI and (31) P MRS scans were obtained from 25 Becker patients and 14 healthy controls using a 7 T MR scanner. Five lower-leg muscles were individually assessed for fat and muscle metabolite levels. In the peroneus, soleus and anterior tibialis muscles with non-increased fat levels, PDE/ATP ratios were higher (P < 0.02) compared with controls, whereas in all muscles with increased fat levels PDE/ATP ratios were higher compared with healthy controls (P ≤ 0.05). The Pi /ATP ratio in the peroneus muscles was higher in muscles with increased fat fractions (P = 0.005), and the PCr/ATP ratio was lower in the anterior tibialis muscles with increased fat fractions (P = 0.005). There were no other significant changes in metabolites, but an increase in tissue pH was found in all muscles of the total group of BMD patients in comparison with healthy controls (P < 0.05). These findings suggest that (31) P MRS can be used to detect early changes in individual muscles of BMD patients, which are present before the onset of fatty infiltration. Copyright © 2014 John Wiley & Sons, Ltd.
Seuwen, Aline; Schroeter, Aileen; Grandjean, Joanes; Rudin, Markus
2015-10-15
Functional proton magnetic resonance spectroscopy (1H-MRS) enables the non-invasive assessment of neural activity by measuring signals arising from endogenous metabolites in a time resolved manner. Proof-of-principle of this approach has been demonstrated in humans and rats; yet functional 1H-MRS has not been applied in mice so far, although it would be of considerable interest given the many genetically engineered models of neurological disorders established in this species only. Mouse 1H-MRS is challenging as the high demands on spatial resolution typically result in long data acquisition times not commensurable with functional studies. Here, we propose an approach based on spectroscopic imaging in combination with the acquisition of the free induction decay to maximize signal intensity. Highly resolved metabolite maps have been recorded from mouse brain with 12 min temporal resolution. This enabled monitoring of metabolic changes following the administration of bicuculline, a GABA-A receptor antagonist. Changes in levels of metabolites involved in energy metabolism (lactate and phosphocreatine) and neurotransmitters (glutamate) were investigated in a region-dependent manner and shown to scale with the bicuculline dose. GABAergic inhibition induced spectral changes characteristic for increased neurotransmitter turnover and oxidative stress. In contrast to metabolic readouts, BOLD and CBV fMRI responses did not scale with the bicuculline dose indicative of the failure of neurovascular coupling. Nevertheless fMRI measurements supported the notion of increased oxidative stress revealed by functional MRS. Hence, the combined analysis of metabolic and hemodynamic changes in response to stimulation provides complementary insight into processes associated with neural activity. Copyright © 2015 Elsevier Inc. All rights reserved.
Zhang, Li; Zhao, Xinming; Ouyang, Han; Wang, Shuang; Zhou, Chunwu
2016-08-22
The purpose of this study was to investigate the diagnostic value of 3.0-T (1)H magnetic resonance spectroscopy ((1)H MRS) in primary malignant hepatic tumors and to compare the effects of (1)H MRS on the diagnostic accuracy of liver-occupying lesions between junior and experienced radiologists. This study included 50 healthy volunteers and 40 consecutive patients (50 lesions). Informed consent was obtained from each subject. Images were obtained on clinical whole-body 3.0-T MR system. Point -Resolved Spectroscopy was used to obtain the spectroscopy image. All conventional images were reviewed blindly by junior radiologist and experienced radiologist, respectively. The choline-containing compounds peak area (CCC-A) was measured with SAGE software, and the choline-containing compound ratio (∆CCC) was calculated. The efficacy of CCC-A and ∆CCC in the diagnosis of primary malignant hepatic tumors was determined by plotting receiver operating characteristic (ROC) curves. We also compared the effects of MRS on the diagnostic accuracy of liver-occupying lesions with junior and experienced radiologist. A significant increase in mean CCC-A was observed in malignant tumors compared with benign tumors. The ROC curve showed ∆CCC had a high discriminatory ability in diagnosing primary malignant hepatic tumors with a sensitivity and specificity of 94.3 and 93.3 %, respectively. The ∆CCC area under the curve (AUC) was 0.97 that was larger than that of both junior and experienced radiologist, while the significantly statistical difference was only obtained between ∆CCC and junior radiologist (P = 0.01). (1)H MRS with ∆CCC demonstrates good efficacy in diagnosing primary malignant hepatic tumors. The technique improves the accuracy of diagnosing liver-occupying lesions, particularly for junior radiologists.
Zhu, Xiao-Hong; Lu, Ming; Chen, Wei
2018-07-01
Brain energy metabolism relies predominantly on glucose and oxygen utilization to generate biochemical energy in the form of adenosine triphosphate (ATP). ATP is essential for maintaining basal electrophysiological activities in a resting brain and supporting evoked neuronal activity under an activated state. Studying complex neuroenergetic processes in the brain requires sophisticated neuroimaging techniques enabling noninvasive and quantitative assessment of cerebral energy metabolisms and quantification of metabolic rates. Recent state-of-the-art in vivo X-nuclear MRS techniques, including 2 H, 17 O and 31 P MRS have shown promise, especially at ultra-high fields, in the quest for understanding neuroenergetics and brain function using preclinical models and in human subjects under healthy and diseased conditions. Copyright © 2018 Elsevier Inc. All rights reserved.
Judging Retirement Reform Using the Strategic Thinking Framework
2012-03-22
separation and that it would be both, “ex ante and ex post incentive-compatible.”23 Several fundamentals of the current MRS, such as retaining a...critically about whether modern conditions lead to the same conclusion of requiring a defined benefit MRS. For example, critical thinking can test ...budget. Many believe this proposal meets the test of acceptability and should be considered for further discussion and analysis. . To support their
31 CFR 315.7 - Authorized forms of registration.
Code of Federal Regulations, 2011 CFR
2011-07-01
.... Example: John A. Jones 123-45-6789. (2) Coownership form. A bond may be registered in the names of two...: John A. Jones 123-45-6789 or Ella S. Jones 987-65-4321. John A. Jones 123-45-6789 or (Miss, Ms. or Mrs... abbreviated to “P.O.D.” Examples: John A. Jones 123-45-6789 payable on death to Mrs. Ella S. Jones. John A...
MR-Based Assessment of Bone Marrow Fat in Osteoporosis, Diabetes, and Obesity
Cordes, Christian; Baum, Thomas; Dieckmeyer, Michael; Ruschke, Stefan; Diefenbach, Maximilian N.; Hauner, Hans; Kirschke, Jan S.; Karampinos, Dimitrios C.
2016-01-01
Bone consists of the mineralized component (i.e., cortex and trabeculae) and the non-mineralized component (i.e., bone marrow). Most of the routine clinical bone imaging uses X-ray-based techniques and focuses on the mineralized component. However, bone marrow adiposity has been also shown to have a strong linkage with bone health. Specifically, multiple previous studies have demonstrated a negative association between bone marrow fat fraction (BMFF) and bone mineral density. Magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS) are ideal imaging techniques for non-invasively investigating the properties of bone marrow fat. In the present work, we first review the most important MRI and MRS methods for assessing properties of bone marrow fat, including methodologies for measuring BMFF and bone marrow fatty acid composition parameters. Previous MRI and MRS studies measuring BMFF and fat unsaturation in the context of osteoporosis are then reviewed. Finally, previous studies investigating the relationship between bone marrow fat, other fat depots, and bone health in patients with obesity and type 2 diabetes are presented. In summary, MRI and MRS are powerful non-invasive techniques for measuring properties of bone marrow fat in osteoporosis, obesity, and type 2 diabetes and can assist in future studies investigating the pathophysiology of bone changes in the above clinical scenarios. PMID:27445977
Detecting uniaxial single domain grains with a modified IRM technique
NASA Astrophysics Data System (ADS)
Mitra, R.; Tauxe, L.; Gee, J. S.
2011-12-01
Mid-ocean ridge basalt (MORB) specimens have often been found to have high ratios of saturation remanence to saturation magnetization (Mrs/Ms). This has been attributed either to dominant cubic anisotropy or to insufficient saturating field leading to overestimation of Mrs/Ms of a dominantly uniaxial single domain (USD) assemblage. To resolve this debate, we develop an independent technique to detect USD assemblages. The experimental protocol involves subjecting the specimen to bidirectional impulse fields at each step. The experiment is similar to the conventional isothermal remanent magnetization (IRM) acquisition experiment but the field is applied twice, in antiparallel directions. We define a new parameter, IRAT, as the ratio of the remanences at each field step and show it to have characteristic behaviour for the two assemblages; IRAT ˜1 at all field steps for USD and <1 with a strong field dependence for multi-axial single domain (MSD) grains. We verified the theoretical predictions experimentally with representative USD and MSD specimens. Experiments with MORBs gave low IRATs for specimens having high Mrs/Ms. This argues for a dominant MSD assemblage in the MORBs, possibly cubic in nature. Although undersaturation of the samples can indeed be a contributing factor to the exceptionally high Mrs/Ms, this study shows that the nature of the assemblage cannot be dominantly USD.
Reyngoudt, Harmen; Paemeleire, Koen; Descamps, Benedicte; De Deene, Yves; Achten, Eric
2011-09-01
Differences in brain energy metabolism have been found between migraine patients and controls in previous phosphorus magnetic resonance spectroscopy ((31)P-MRS) studies, most of them emphasizing migraine with aura (MwA). The aim of this study was to verify potential changes in resting-state brain energy metabolism in patients with migraine without aura (MwoA) compared to control subjects by (31)P-MRS at 3 tesla. Quantification was performed using the phantom replacement technique. MRS measurements were performed interictally and in the medial occipital lobe of 19 MwoA patients and 26 age-matched controls. A significantly decreased phosphocreatine concentration ([PCr]) was found as in previous studies. While adenosine triphosphate concentration ([ATP]) was considered to be constant in previously published work, this study found a significant decrease in the measured [ATP] in MwoA patients. The inorganic phosphate ([P(i)]) and magnesium ([Mg(2+)]) concentrations were not significantly different between MwoA patients and controls. The altered metabolic concentrations indicate that the energy metabolism in MwoA patients is impaired, certainly in a subgroup of patients. The actual decrease in [ATP] adds further strength to the theory of the presence of a mitochondrial component in the pathophysiology of migraine.
Chambers, A F
1999-02-01
The Metastasis Research Society (MRS) has held its International Congress every two years since 1986, and alternates between European and North American meeting venues. The next MRS International Congress will be held in London, UK in the year 2000, and will be hosted by the current MRS President, Dr. Suzanne Eccles (Institute of Cancer Research, Sutton, UK). Dr. Eccles took over from the out-going President, Dr. William Stetler-Stevenson (National Institutes of Health, Bethesda, MD, USA), at the San Diego meeting. Information on joining the Metastasis Research Society, which includes a subscription to the Society's journal, Clinical and Experimental Metastasis, can be obtained from Dr. Eccles (suzan@icr.ac.uk) or from the newly-elected Secretary/Treasurer Dr. Danny Welch (Hershey, PA, USA; drw9@psu.edu). The meeting was organized by Darwin Medical Communications Ltd (Gill Heaton, Oxford, UK), who have placed the full program on the meeting web site (http:@www.sparks.co.uk/mrs). It is envisaged that full abstracts of all the presentations will be placed on the Metastasis Research Society web site, which is currently under construction. Corporate sponsors for the San Diego meeting included Agouron Pharmaceuticals, Becton Dickinson & Co, Zeneca Pharma SA, Schering AG, AntiCancer Inc, Oncogene Research Products, Daiichi Seiyaku Co Ltd and Novartis Pharma AG.
Boon, A J; Tans, J T; Delwel, E J; Egeler-Peerdeman, S M; Hanlo, P W; Wurzer, J A; Avezaat, C J; de Jong, D A; Gooskens, R H; Hermans, J
1998-01-01
The value of the measurements of CSF outflow resistance (Rcsf) relative to predicting outcome after shunting was studied. In a group of 101 patients with mainly idiopathic normal pressure hydrocephalus (NPH) Rcsf was obtained by lumbar constant flow infusion. Gait disturbance and dementia were quantified using an NPH scale (NPHS) and disability by the Modified Rankin scale (MRS). Patients were assessed before and at 1, 3, 6, 9 and 12 months after surgery. Outcome measures were differences between the preoperative and last NPHS and MRS scores. Improvement was defined as a change of > or = 15% in NPHS and > or = 1 grade in MRS. Intention-to-treat analysis of all patients at one year yielded improvement of 57% in NPHS and 59% in MRS. Efficacy analysis, excluding comorbidity unrelated to NPH, revealed positive predictive values of around 80% at Rcsf < 18, and between 90% and 100% at Rcsf > or = 18 mm Hg/ml/min. For Rcsf > or = 18, the likelihood ratios were also higher. We conclude that the best predictor of the response to shunting is an Rcsf > or = 18 mm Hg/ml/min. Since two-thirds of the patients with Rcsf < 18 showed improvement as well, these patients should not be denied shunting.
Buehler, Tania; Bally, Lia; Dokumaci, Ayse Sila; Stettler, Christoph; Boesch, Chris
2016-06-01
Glycogen is a major substrate in energy metabolism and particularly important to prevent hypoglycemia in pathologies of glucose homeostasis such as type 1 diabetes mellitus (T1DM). (13) C-MRS is increasingly used to determine glycogen in skeletal muscle and liver non-invasively; however, the low signal-to-noise ratio leads to long acquisition times, particularly when glycogen levels are determined before and after interventions. In order to ease the requirements for the subjects and to avoid systematic effects of the lengthy examination, we evaluated if a standardized preparation period would allow us to shift the baseline (pre-intervention) experiments to a preceding day. Based on natural abundance (13) C-MRS on a clinical 3 T MR system the present study investigated the test-retest reliability of glycogen measurements in patients with T1DM and matched controls (n = 10 each group) in quadriceps muscle and liver. Prior to the MR examination, participants followed a standardized diet and avoided strenuous exercise for two days. The average coefficient of variation (CV) of myocellular glycogen levels was 9.7% in patients with T1DM compared with 6.6% in controls after a 2 week period, while hepatic glycogen variability was 13.3% in patients with T1DM and 14.6% in controls. For comparison, a single-session test-retest variability in four healthy volunteers resulted in 9.5% for skeletal muscle and 14.3% for liver. Glycogen levels in muscle and liver were not statistically different between test and retest, except for hepatic glycogen, which decreased in T1DM patients in the retest examination, but without an increase of the group distribution. Since the CVs of glycogen levels determined in a "single session" versus "within weeks" are comparable, we conclude that the major source of uncertainty is the methodological error and that physiological variations can be minimized by a pre-study standardization. For hepatic glycogen examinations, familiarization sessions (MR and potentially strenuous interventions) are recommended. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Lin, Ning; Brouillard, Adam M; Keigher, Kiffon M; Lopes, Demetrius K; Binning, Mandy J; Liebman, Kenneth M; Veznedaroglu, Erol; Magarik, Jordan A; Mocco, J; Duckworth, Edward A; Arthur, Adam S; Ringer, Andrew J; Snyder, Kenneth V; Levy, Elad I; Siddiqui, Adnan H
2015-11-01
Utilization of the Pipeline embolization device (PED) in complex ruptured aneurysms has not been well studied. We evaluated the safety and effectiveness data from five participating US centers. Records of patients with ruptured cerebral aneurysms who underwent PED treatment between 2011 and 2013 were retrospectively reviewed. 26 patients with ruptured aneurysms underwent PED treatment (mean age 51.4 ± 13.2 years;16 women). At presentation, 8 patients (30.8%) had a Hunt-Hess grade of IV or above; 11 required extraventricular drain placement. Aneurysm morphologies were: 8 dissecting, 8 blister-like, 6 fusiform, and 4 saccular. There were 22 anterior circulation and 4 posterior circulation aneurysms. PED deployment was successful in all patients, with adjunctive coiling utilized in 12. Periprocedural complications occurred in 5 (19.2%), including 3 inhospital deaths. 23 patients (88.5%) had postoperative angiography at a mean of 5.9 months: 18 aneurysms (78.3%) were completely occluded, 3 (13.0%) had residual neck filling, and 2 (8.7%) had residual dome filling. All blister-type aneurysms were completely occluded at follow-up. Clinical follow-up was available for an average of 10.1 months (range 2-21 months), with one asymptomatic in-stent stenosis and one asymptomatic thromboembolic stroke noted. Good outcome (modified Rankin Scale (mRS) score of 0-2) was achieved in 20 patients (76.9%), fair (mRS 3-4) in 3 (11.5%), and 3 died (11.5%). The PED can be utilized for ruptured aneurysms and is a good option for blister-type aneurysms. However, due to periprocedural complications, it should be reserved for lesions that are difficult to treat by conventional clipping or coiling. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Hillary Clinton takes up defense of U.S. aid for family planning overseas.
Cohen, S A
1996-12-20
In November 1996 during her address to the Sixth Conference of Wives of Heads of State and Government of the Americas in La Paz, Colombia, and in her weekly newspaper column, US first lady Hillary Rodham Clinton pledged her own and the Clinton administration's complete support for reversing the severe reduction in funds for the international family planning program imposed by the 104th Congress. This revelation reflected the administration's preparation for a strong and vocal defense of the international family planning program, which will be facing its greatest political test in February 1997. Bolivia has the highest maternal mortality rate in South America, and half the deaths are due to illegal, unsafe abortions. Mrs. Clinton presented a $2.25 million USAID award to a $5 million Pan American Health Organization program that aims to reduce maternal mortality. In her December 3, 1996, column, she used family planning campaigns in Bolivia as an illustration of sensible, cost-effective, and long-term strategies for improving women's health, strengthening families, and reducing the abortion rate. Such programs educate people about the benefits of birth spacing, breast feeding, good nutrition, prenatal and postpartum visits, and safe deliveries. Mrs. Clinton has also visited other poor countries to learn about the special needs and conditions of women's lives. UN Ambassador Madeleine Albright has recently been nominated to be the first female Secretary of State. Many people see her commitment to improving the status of women through development efforts and her recognition of the close relationship between development and diplomacy as encouraging. The concern and commitment of these two powerful women could prove valuable in the upcoming test for international family planning aid. Congress must vote on a resolution to approve Clinton's report that the reduced funding is having a negative impact no later than February 28. If both the House and the Senate pass the resolution, already appropriated funds will be released in March rather than in July.
Magnetic Resonance Medical Imaging (MRI)-from the inside
NASA Astrophysics Data System (ADS)
Bottomley, Paul
There are about 36,000 magnetic resonance imaging (MRI) scanners in the world, with annual sales of 2500. In the USA about 34 million MRI studies are done annually, and 60-70% of all scanners operate at 1.5 Tesla (T). In 1982 there were none. How MRI got to be-and how it got to1.5T is the subject of this talk. Its an insider's view-mine-as a physics PhD student at Nottingham University when MRI (almost) began, through to the invention of the 1.5T clinical MRI scanner at GE's research center in Schenectady NY.Before 1977 all MRI was done on laboratory nuclear magnetic resonance instruments used for analyzing small specimens via chemical shift spectroscopy (MRS). It began with Lauterbur's 1973 observation that turning up the spectrometer's linear gradient magnetic field, generated a spectrum that was a 1D projection of the sample in the direction of the gradient. What followed in the 70's was the development of 3 key methods of 3D spatial localization that remain fundamental to MRI today.As the 1980's began, the once unimaginable prospect of upscaling from 2cm test-tubes to human body-sized magnets, gradient and RF transmit/receive systems, was well underway, evolving from arm-sized, to whole-body electromagnet-based systems operating at <0.2T. I moved to Johns Hopkins University to apply MRI methods to localized MRS and study cardiac metabolism, and then to GE to build a whole-body MRS machine. The largest uniform magnet possible-then, a 1.5T superconducting system-was required. Body MRI was first thought impossible above 0.35T due to RF penetration, detector coil and signal-to-noise ratio (SNR) issues. When GE finally did take on MRI, their plan was to drop the field to 0.3T. We opted to make MRI work at 1.5T instead. The result was a scanner that could study both anatomy and metabolism with a SNR way beyond its lower field rivals. MRI's success truly reflects the team efforts of many: from the NMR physics to the engineering of magnets, gradient and RF systems.
PROJECT MERCURY SUMMARY CONFERENCE - NASA - HOUSTON, TX
1963-10-01
In October 1963, the Project Mercury Summary Conference was held in the Houston, TX, Coliseum. This series of 44 photos is documentation of that conference. A view of the Houston, TX, Coliseum, and parking area in front with a Mercury Redstone Rocket setup in the parking lot for display (S63-16451). A view of an Air Force Atlas Rocket, a Mercury Redstone Rocket, and a Mercury Spacecraft on a test booster on display in the front area of the Coliseum (S63-16452). A view an Air Force Atlas Rocket and a Mercury Redstone Rocket set up for display with the Houston City Hall in the background (S63- 16453). This view shows the Atlas Rocket, Mercury Redstone, and Mercury Test Rocket with the Houston, TX, Coliseum in the background (S63- 16454). A balcony view, from the audience right side, of the attendees looking at the stage (S63-16455). A view of the NASA Space Science Demonstration with equipment setup on a table, center stage and Space Science Specialist briefing the group as he pours Liquid Oxygen into a beaker (S63-16456). View of the audience from the balcony on the audience right showing the speakers lecturn on stage to the audience left (S63-16457). A view of attendees in the lobby. Bennet James, MSC Public Affairs Office is seen to the left of center (S63-16458). Another view of the attendees in the lobby (S63- 16459). In this view, Astronaut Neil Armstrong is seen writing as others look on (S63-16460). In this view of the attendees, Astronauts Buzz Aldrin and Walt Cunningham are seen in the center of the shot. The October Calendar of Events is visable in the background (S63-16461). Dr. Charles Berry is seen in this view to the right of center, seated in the audience (S63-16462). View of " Special Registration " and the five ladies working there (S63-16463). A view from behind the special registration table, of the attendees being registered (S63-16464). A view of a conference table with a panel seated. (R-L): Dr. Robert R. Gilruth, Hugh L. Dryden, Walter C. Williams, and an unidentified man (S63- 16465). A closeup of the panel at the table with Dr. Gilruth on the left (S63-16466). About the same shot as number S63-16462, Dr. Berry is seen in this shot as well (S63-16467). In this view the audio setup is seen. In the audience, (L-R): C. C. Kraft, Vernon E. (Buddy) Powell, Public Affairs Office (PAO); and, in the foreground mixing the audio is Art Tantillo; and, at the recorder is Doyle Hodges both of the audio people are contractors that work for PAO at MSC (S63-16468). In this view Maxime Faget is seen speaking at the lecturn (S63-16469). Unidentified person at the lecturn (S63-16470). In this view the motion picture cameras and personel are shown documenting the conference (S63-16471). A motion picture cameraman in the balcony is shown filming the audience during a break (S63- 16472). Family members enjoy an exhibit (S63-16473). A young person gets a boost to look in a Gemini Capsule on display (S63-16474). A young person looks at the Gemini Capsule on display (S63-16475). Dr. Robert R. Gilruth is seen at the conference table (S63-16476). Walt Williams is seen in this view at the conference table (S63-16477). Unidentified man sitting next to Walt Williams (S63-16478). (L-R): Seated at the conference table, Dr. Robert Gilruth, Hugh L. Dryden, and Walt Williams (S63- 16479). Group in lobby faces visable, (L-R): Walt Williams, unidentified person, Dr. Robert Gilruth, Congressman (S63-16480). Man in uniform at the lecturn (S63-16481). Astronaut Leroy Gordon Cooper at the lecturn (S63-16482). Astronaut Cooper at the lecturn with a picture on the screen with the title, " Astronaut Names for Spacecraft " (S63-16483). Dr. Gilruth at the lecturn (S63-16484). Walt Williams at the lecturn (S63-16485). Unidentified man at the lecturn (S63-16486). John H. Boynton addresses the Summary Conference (S63-16487). (L-R): Astronaut Leroy Gordon Cooper, Mrs. Cooper, Senator Cris Cole, and Mrs. Cole (S63- 16488). In this view in the lobby, Senator and Mrs. Cris Cole, with Astronaut Gordon Cooper standing near the heatshield, and Mrs. Cooper; next, on the right is a press photographer (S63-16489). (L-R): Astronaut L. Gordon Cooper and Mrs. Cooper, unidentified man, and Senator Walter Richter (S63-16490). (L-R): Eugene Horton, partially obscured, briefs a group on the Mercury Spacecraft, an unidentified person, Harold Ogden, a female senator, Senator Chris Cole, Mrs. Cole, an unidentified female, Senator Walter Richter, Jim Bower, and an unidentified female (S63-16491). In this view, Mrs. Jim Bates is seen in the center, and Senator Walter Richter to the right (S63- 16492). The next three (3) shots are 4X5 CN (S63-16493 - S63-16495). In this view a NASA Space Science Demonstration is seen (S63-16493). In this view a shot of the conference table is seen, and, (L-R): Dr. Robert R. Gilruth, Hugh L. Dryden, Mr. Walter Williams, and an unidentfied man (S63-16494 - S63-16495). HOUSTON, TX
Fort Leavenworth: Its Churches and Schools
1912-01-01
Mary Fuller, Mrs. F. L. Munson, and Mrs. Charles Gerhardt , while there are at present 116 3~idnd ai$~tUwuwn~rftt two associate members, Mtrs. G. P. Pond...hereby empowered and authorized to levy a tax each year upon the franchises and propert~y of railroad corm- panies, bridge companies and other...ztu? 1Buiit 14 SECTION 3. TPhat for the purpose of listing, as- sessing and valuing the franchises and property of railroad comnpapnies, bridge
ISSION CONTROL CENTER (MCC) - GEMINI-TITAN (GT)-IV - MSC
1965-06-03
S65-30411 (9 June 1965) --- The families of Gemini 4 astronauts James A. McDivitt and Edward H. White II visited the Mission Control Center in Houston. In the foreground, left to right, are Mrs. Patricia McDivitt, daughter Bonnie White, Mrs. Patricia White, flight director Christopher C. Kraft Jr., and Edward White III. Each of the family members talked with the astronauts as they passed over the United States. Photo credit: NASA
Space Power Integration: Perspectives from Space Weapons Officers
2006-12-01
staff at Air University Press, Dr. Philip Adkins, Mrs. Sherry Terrell , and Mrs. Vivian O’Neal. Their creation of an integrated book from nine...Techniques of Complex Systems Science: An Overview ( Ann Arbor, MI: Center for the Study of Complex Sys- tems, University of Michigan, 9 July 2003), 34...Depart- ment of the Navy Space Policy, 26 August 1993. Shalizi, Cosma Rohilla. Methods and Techniques of Complex Systems Science: An Overview. Ann
Boosting Contextual Information for Deep Neural Network Based Voice Activity Detection
2015-02-01
multi-resolution stacking (MRS), which is a stack of ensemble classifiers. Each classifier in a building block inputs the concatenation of the predictions ...a base classifier in MRS, named boosted deep neural network (bDNN). bDNN first generates multiple base predictions from different contexts of a single...frame by only one DNN and then aggregates the base predictions for a better prediction of the frame, and it is different from computationally
Serial proton MR spectroscopy and diffusion tensor imaging in infantile Balo's concentric sclerosis.
Dreha-Kulaczewski, Steffi F; Helms, Gunther; Dechent, Peter; Hofer, Sabine; Gärtner, Jutta; Frahm, Jens
2009-02-01
Proton magnetic resonance spectroscopy (MRS) and diffusion tensor imaging (DTI) yield different parameters for characterizing the evolution of a demyelinating white matter disease. The purpose was to elucidate biochemical and microstructural changes in Balo's concentric sclerosis lesions and to correlate the findings with the clinical course. Localized short-echo time MRS and DTI were performed over 6 years in a left occipital lesion of a female patient (age at onset 13.8 years) with Balo's concentric sclerosis. A right homonym hemianopsia persisted. Metabolite patterns were in line with initial active demyelination followed by gliosis and partial recovery of neuroaxonal metabolites. Fractional anisotropy and mean diffusivity of tissue water remained severely altered. Fiber tracking confirmed a disruption in the geniculo-calcarine tract as well as involvement of the corpus callosum. MRS and DTI depict complementary parameters, but DTI seems to correlate better with clinical symptoms.
Manders, Eric-Jan; José, Eurico; Solis, Manuel; Burlison, Janeen; Nhampossa, José Leopoldo; Moon, Troy
2010-01-01
We have adopted the Open Medical Record System (OpenMRS) framework to implement an electronic patient monitoring system for an HIV care and treatment program in Mozambique. The program provides technical assistance to the Ministry of Health supporting the scale up of integrated HIV care and support services in health facilities in rural resource limited settings. The implementation is in use for adult and pediatric programs, with ongoing roll-out to cover all supported sites. We describe early experiences in adapting the system to the program needs, addressing infrastructure challenges, creating a regional support team, training data entry staff, migrating a legacy database, deployment, and current use. We find that OpenMRS offers excellent prospects for in-country development of health information systems, even in severely resource limited settings. However, it also requires considerable organizational infrastructure investment and technical capacity building to ensure continued local support.
Dynamic nuclear polarization and optimal control spatial-selective 13C MRI and MRS
NASA Astrophysics Data System (ADS)
Vinding, Mads S.; Laustsen, Christoffer; Maximov, Ivan I.; Søgaard, Lise Vejby; Ardenkjær-Larsen, Jan H.; Nielsen, Niels Chr.
2013-02-01
Aimed at 13C metabolic magnetic resonance imaging (MRI) and spectroscopy (MRS) applications, we demonstrate that dynamic nuclear polarization (DNP) may be combined with optimal control 2D spatial selection to simultaneously obtain high sensitivity and well-defined spatial restriction. This is achieved through the development of spatial-selective single-shot spiral-readout MRI and MRS experiments combined with dynamic nuclear polarization hyperpolarized [1-13C]pyruvate on a 4.7 T pre-clinical MR scanner. The method stands out from related techniques by facilitating anatomic shaped region-of-interest (ROI) single metabolite signals available for higher image resolution or single-peak spectra. The 2D spatial-selective rf pulses were designed using a novel Krotov-based optimal control approach capable of iteratively fast providing successful pulse sequences in the absence of qualified initial guesses. The technique may be important for early detection of abnormal metabolism, monitoring disease progression, and drug research.
Apollo 12 Crewmembers - Greeting - Family - Arrival - Ellington AFB (EAFB), TX
1969-11-29
S69-60759 (29 Nov. 1969) --- Members of the Apollo 12 lunar landing mission's crew are greeted by their wives and children at the front of a large crowd on hand to welcome the three home. The Mobile Quarantine Facility (MQF), with the crew inside, arrived at Ellington Air Force Base aboard a United States Air Force C-141 transport jet in the early morning hours of Nov. 29, 1969. The crew men, looking out the MQF window at the crowd, are from left to right, astronauts Charles Conrad Jr., Richard F. Gordon Jr. and Alan L. Bean. Their wives are, from left to right, Mrs. Barbara Gordon, Mrs. Jane Conrad and Mrs. Sue Bean. The women are wearing lei's, an Hawaiian tradition. The crew members were taken to Hawaii from their Pacific Ocean recovery site aboard the USS Hornet, prime recovery vessel for the mission.
Advances in MR imaging for cervical spondylotic myelopathy.
Ellingson, Benjamin M; Salamon, Noriko; Holly, Langston T
2015-04-01
To outline the pathogenesis of cervical spondylotic myelopathy (CSM), the correlative abnormalities observed on standard magnetic resonance imaging (MRI), the biological implications and current status of diffusion tensor imaging (DTI), and MR spectroscopy (MRS) as clinical tools, and future directions of MR technology in the management of CSM patients. A systematic review of the pathogenesis and current state-of-the-art in MR imaging technology for CSM was performed. CSM is caused by progressive, degenerative, vertebral column abnormalities that result in spinal cord damage related to both primary mechanical and secondary biological injuries. The T2 signal change on conventional MRI is most commonly associated with neurological deficits, but tends not to be a sensitive predictor of recovery of function. DTI and MRS show altered microstructure and biochemistry that reflect patient-specific pathogenesis. Advanced imaging techniques, including DTI and MRS, show higher sensitivity to microstructural and biochemical changes within the cord, and may aid in management of CSM patients.
Degradation of Histamine by Lactobacillus plantarum Isolated from Miso Products.
Kung, Hsien-Feng; Lee, Yi-Chen; Huang, Ya-Ling; Huang, Yu-Ru; Su, Yi-Cheng; Tsai, Yung-Hsiang
2017-10-01
Histamine is a toxic chemical and is the causative agent of food poisoning. This foodborne toxin may be degraded by the oxidative deamination activity of certain microorganisms. In this study, we isolated four histamine-degrading Lactobacillus plantarum bacteria from miso products. Among them, L. plantarum D-103 exhibited 100% degradation of histamine in de Man Rogosa Sharpe (MRS) broth containing 50 ppm of histamine after 24 h of incubation at 30°C. The optimal growth, histamine oxidase, and histamine-degrading activity of L. plantarum D-103 were observed in histamine MRS broth at pH 7.0, 3% NaCl, and 30°C. It also exhibited tolerance to broad ranges of pH (4 to 10) and salt concentrations (0 to 12%) in histamine MRS broth. Therefore, the histamine-degrading L. plantarum D-103 might be used as an additive culture to prevent histamine accumulation in miso products during fermentation.
New advances in MR-compatible bioartificial liver
Jeffries, Rex E.; Macdonald, Jeffrey M.
2015-01-01
MR-compatible bioartificial liver (BAL) studies have been performed for 30 years and are reviewed. There are two types of study: (i) metabolism and drug studies using multinuclear MRS; primarily short-term (< 8 h) studies; (ii) the use of multinuclear MRS and MRI to noninvasively define the features and functions of BAL systems for long-term liver tissue engineering. In the latter, these systems often undergo not only modification of the perfusion system, but also the construction of MR radiofrequency probes around the bioreactor. We present novel MR-compatible BALs and the use of multinuclear MRS (13C, 19F, 31P) for the noninvasive monitoring of their growth, metabolism and viability, as well as 1H MRI methods for the determination of flow profiles, diffusion, cell distribution, quality assurance and bioreactor integrity. Finally, a simple flexible coil design and circuit, and life support system, are described that can make almost any BAL MR-compatible. PMID:22351642
Physics and instrumentation for imaging in-vivo drug distribution.
Singh, M; Waluch, V
2000-03-15
Several imaging methods are currently available to measure drugs noninvasively. Of these, two techniques are today central to such measurements: nuclear imaging and magnetic resonance imaging/spectroscopy (MRI and MRS). While other methods, such as optical techniques, are rapidly gaining in interest, they have not yet attained the degree of development that makes them effective in measuring drugs in living systems, except in a small number of examples. The following introduction provides some basic elements of the potential and the limitations of both nuclear imaging and MRI/MRS techniques, methods that will be used in the studies described in the articles in this issue. However, and for those desiring to gain a better understanding of both methods, the reader is advised to consult much more extensive reviews and books describing such methods. A suggested list of books and articles on Nuclear Imaging and MRI/MRS is given.
Full-field fabric stress mapping by micro Raman spectroscopy in a yarn push-out test.
Lei, Z K; Qin, F Y; Fang, Q C; Bai, R X; Qiu, W; Chen, X
2018-02-01
The full-field stress distribution of a two-dimensional plain fabric was mapped using micro Raman spectroscopy (MRS) through a novel yarn push-out test, simulating a quasi-static projectile impact on the fabric. The stress-strain relationship for a single yarn was established using a digital image correlation method in a single-yarn tensile test. The relationship between Raman peak shift and aramid Kevlar 49 yarn stress was established using MRS in a single-yarn tensile test. An out-of-plane loading test was conducted on an aramid Kevlar 49 plain fabric, and the yarn stress was measured using MRS. From the full-field fabric stress distribution, it can be observed that there is a cross-shaped distribution of high yarn stress; this result would be helpful in further studies on load transfer on a fabric during a projectile impact.
[Advances in the physiopathology of epileptogenesis: metabolic aspects in vivo].
García-Segura, J M
This communication shows how proton magnetic resonance spectroscopy (MRS) is currently being employed in the study or the diagnosis of epilepsy. With this goal, the kind of biochemical information of cerebral parenchyma available with this non invasive technique is first introduced in a succinct way. The value of this metabolic information is then illustrated through several cases of temporal and extratemporal epilepsy, for which magnetic resonance imaging was either non diagnostic or uncertain. In this context, the asymmetry index, very useful for the lateralization of epileptogenic foci on the basis of quantitative spectroscopic criteria, is defined. Finally, other potentials of MRS, beyond its ability to elucidate the existence of neuronal damage in the epileptogenic zone, are considered. Hence, cases with postictally increased lactate, or increased glutamine/glutamate without apparent neuronal damage, are presented as good examples of the diagnostic or lateralizing value of MRS.
Reynolds, Joshua C; Grunau, Brian E; Rittenberger, Jon C; Sawyer, Kelly N; Kurz, Michael C; Callaway, Clifton W
2016-12-20
Little evidence guides the appropriate duration of resuscitation in out-of-hospital cardiac arrest, and case features justifying longer or shorter durations are ill defined. We estimated the impact of resuscitation duration on the probability of favorable functional outcome in out-of-hospital cardiac arrest using a large, multicenter cohort. This was a secondary analysis of a North American, single-blind, multicenter, cluster-randomized, clinical trial (ROC-PRIMED [Resuscitation Outcomes Consortium Prehospital Resuscitation Using an Impedance Valve and Early Versus Delayed]) of consecutive adults with nontraumatic, emergency medical services-treated out-of-hospital cardiac arrest. Primary exposure was duration of resuscitation in minutes (onset of professional resuscitation to return of spontaneous circulation [ROSC] or termination of resuscitation). Primary outcome was survival to hospital discharge with favorable outcome (modified Rankin scale [mRS] score of 0-3). Subjects were additionally classified as survival with unfavorable outcome (mRS score of 4-5), ROSC without survival (mRS score of 6), or without ROSC. Subject accrual was plotted as a function of resuscitation duration, and the dynamic probability of favorable outcome at discharge was estimated for the whole cohort and subgroups. Adjusted logistic regression models tested the association between resuscitation duration and survival with favorable outcome. The primary cohort included 11 368 subjects (median age, 69 years [interquartile range, 56-81 years]; 7121 men [62.6%]). Of these, 4023 (35.4%) achieved ROSC, 1232 (10.8%) survived to hospital discharge, and 905 (8.0%) had an mRS score of 0 to 3 at discharge. Distribution of cardiopulmonary resuscitation duration differed by outcome (P<0.00001). For cardiopulmonary resuscitation duration up to 37.0 minutes (95% confidence interval, 34.9-40.9 minutes), 99% with an eventual mRS score of 0 to 3 at discharge achieved ROSC. The dynamic probability of an mRS score of 0 to 3 at discharge declined over elapsed resuscitation duration, but subjects with initial shockable cardiac rhythm, witnessed cardiac arrest, and bystander cardiopulmonary resuscitation were more likely to survive with favorable outcome after prolonged efforts (30-40 minutes). After adjustment for prehospital (odds ratio, 0.93; 95% confidence interval, 0.92-0.95) and inpatient (odds ratio, 0.97; 95% confidence interval, 0.95-0.99) covariates, resuscitation duration was associated with survival to discharge with an mRS score of 0 to 3. Shorter resuscitation duration was associated with likelihood of favorable outcome at hospital discharge. Subjects with favorable case features were more likely to survive prolonged resuscitation up to 47 minutes. URL: http://clinicaltrials.gov. Unique identifier: NCT00394706. © 2016 American Heart Association, Inc.
Harada, Kuniaki; Honmou, Osamu; Liu, He; Bando, Michio; Houkin, Kiyohiro; Kocsis, Jeffery D.
2008-01-01
Proton magnetic resonance spectroscopy (1-H MRS) has revealed changes of metabolites in acute cerebral infarction. Although the drastic changes of lactate and N-acetyl-aspartate have been reported to be useful indicators of the ischemic damage in both humans and experimental animals, lipid signals are also detected by the short echo time sequence 1–5 days after ischemia. The objective of this study was to find a novel technique to isolate lactate signals from lipid signals in the ischemic brain. First, MRS was used to study the lipid and lactate components of a spherical phantom in vitro, and parameters were established to separate these components in vitro. Then, MR measurements were obtained from the brains of middle cerebral artery occlusion rats. All MR measurements were performed using a 7-T (300 MHz), 18.3-cm-bore superconducting magnet (Oxford Magnet Technologies) interfaced to a Unity INOVA Imaging System (Varian Technologies). T2-weighted images were obtained from a 1.0-mm-thick coronal section using a 3-cm field of view. It is well known that lipid has a shorter and lactate a longer T2 relaxation time. These distinct magnetic characteristics allowed us to separate the lactate signal from the lipid signal. Thus, adjustment of the echo time is essential to analyze the metabolites in acute cerebral infarction, which may be useful in both the clinic and laboratory. PMID:17196558
Piotin, Michel; Biondi, Alessandra; Sourour, Nader; Mounayer, Charbel; Jaworski, Maciej; Mangiafico, Salvatore; Andersson, Tommy; Söderman, Michael; Goffette, Pierre; Anxionnat, René; Blanc, Raphaël
2018-04-18
Intrasaccular aneurysm flow disruption represents an emerging endovascular approach to treat intracranial aneurysms. The purpose of this study was to determine the clinical and angiographic outcomes of using the LUNA aneurysm embolisation system (AES) for treatment of intracranial aneurysms. The LUNA AES Post-Market Clinical Follow-Up study is a prospective, multicentre, single-arm study that was designed to evaluate device safety and efficacy. Bifurcation and sidewall aneurysms were included. Aneurysm occlusion was assessed using the Raymond-Roy classification scale. Disability was assessed using the Modified Rankin Scale (mRS). Morbidity was defined as mRS >2 if baseline mRS ≤2, increase in mRS of 1 or more if baseline mRS >2, or mRS >2 if aneurysm was ruptured at baseline. Clinical and angiographic follow-up was conducted at 6, 12 and 36 months. Sixty-three subjects with 64 aneurysms were enrolled. Most aneurysms were unruptured (60/63 (95.2%)); 49 were bifurcation or terminal (49/64 (76.6%)). Mean aneurysm size was 5.6±1.8 mm (range, 3.6-14.9 mm), and mean neck size was 3.8±1.0 mm (range, 1.9-8.7 mm). Though immediate postoperative adequate occlusion was low (11/63, 18%), adequate occlusion was achieved in 78.0% (46/59) and 79.2% (42/53) of the aneurysms at 12 months and 36 months, respectively. Four patients were retreated by the 12-month follow-up (4/63 (6.3%)) and three patients were retreated by the 36-month follow-up (3/63 (4.8%)). There were two major strokes (2/63 (3.2%)), one minor stroke (1/63 (1.6%)) and three incidents of intracranial haemorrhage in two subjects (2/63 (3.2%)) prior to the 12-month follow-up. There was one instance of mortality (1/63, 1.6%). Morbidity was 0% (0/63) and 1.8% (1/63) at the 12-month and 36-month follow-ups, respectively. LUNA AES is safe and effective for the treatment of bifurcation and sidewall aneurysms. ISRCTN72343080; Results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
NASA Astrophysics Data System (ADS)
Behroozmand, Ahmad A.; Auken, Esben; Fiandaca, Gianluca; Christiansen, Anders Vest; Christensen, Niels B.
2012-08-01
We present a new, efficient and accurate forward modelling and inversion scheme for magnetic resonance sounding (MRS) data. MRS, also called surface-nuclear magnetic resonance (surface-NMR), is the only non-invasive geophysical technique that directly detects free water in the subsurface. Based on the physical principle of NMR, protons of the water molecules in the subsurface are excited at a specific frequency, and the superposition of signals from all protons within the excited earth volume is measured to estimate the subsurface water content and other hydrological parameters. In this paper, a new inversion scheme is presented in which the entire data set is used, and multi-exponential behaviour of the NMR signal is approximated by the simple stretched-exponential approach. Compared to the mono-exponential interpretation of the decaying NMR signal, we introduce a single extra parameter, the stretching exponent, which helps describe the porosity in terms of a single relaxation time parameter, and helps to determine correct initial amplitude and relaxation time of the signal. Moreover, compared to a multi-exponential interpretation of the MRS data, the decay behaviour is approximated with considerably fewer parameters. The forward response is calculated in an efficient numerical manner in terms of magnetic field calculation, discretization and integration schemes, which allows fast computation while maintaining accuracy. A piecewise linear transmitter loop is considered for electromagnetic modelling of conductivities in the layered half-space providing electromagnetic modelling of arbitrary loop shapes. The decaying signal is integrated over time windows, called gates, which increases the signal-to-noise ratio, particularly at late times, and the data vector is described with a minimum number of samples, that is, gates. The accuracy of the forward response is investigated by comparing a MRS forward response with responses from three other approaches outlining significant differences between the three approaches. All together, a full MRS forward response is calculated in about 20 s and scales so that on 10 processors the calculation time is reduced to about 3-4 s. The proposed approach is examined through synthetic data and through a field example, which demonstrate the capability of the scheme. The results of the field example agree well the information from an in-site borehole.
Global brain metabolic quantification with whole-head proton MRS at 3 T.
Kirov, Ivan I; Wu, William E; Soher, Brian J; Davitz, Matthew S; Huang, Jeffrey H; Babb, James S; Lazar, Mariana; Fatterpekar, Girish; Gonen, Oded
2017-10-01
Total N-acetyl-aspartate + N-acetyl-aspartate-glutamate (NAA), total creatine (Cr) and total choline (Cho) proton MRS ( 1 H-MRS) signals are often used as surrogate markers in diffuse neurological pathologies, but spatial coverage of this methodology is limited to 1%-65% of the brain. Here we wish to demonstrate that non-localized, whole-head (WH) 1 H-MRS captures just the brain's contribution to the Cho and Cr signals, ignoring all other compartments. Towards this end, 27 young healthy adults (18 men, 9 women), 29.9 ± 8.5 years old, were recruited and underwent T 1 -weighted MRI for tissue segmentation, non-localizing, approximately 3 min WH 1 H-MRS (T E /T R /T I = 5/10/940 ms) and 30 min 1 H-MR spectroscopic imaging (MRSI) (T E /T R = 35/2100 ms) in a 360 cm 3 volume of interest (VOI) at the brain's center. The VOI absolute NAA, Cr and Cho concentrations, 7.7 ± 0.5, 5.5 ± 0.4 and 1.3 ± 0.2 mM, were all within 10% of the WH: 8.6 ± 1.1, 6.0 ± 1.0 and 1.3 ± 0.2 mM. The mean NAA/Cr and NAA/Cho ratios in the WH were only slightly higher than the "brain-only" VOI: 1.5 versus 1.4 (7%) and 6.6 versus 5.9 (11%); Cho/Cr were not different. The brain/WH volume ratio was 0.31 ± 0.03 (brain ≈ 30% of WH volume). Air-tissue susceptibility-driven local magnetic field changes going from the brain outwards showed sharp gradients of more than 100 Hz/cm (1 ppm/cm), explaining the skull's Cr and Cho signal losses through resonance shifts, line broadening and destructive interference. The similarity of non-localized WH and localized VOI NAA, Cr and Cho concentrations and their ratios suggests that their signals originate predominantly from the brain. Therefore, the fast, comprehensive WH- 1 H-MRS method may facilitate quantification of these metabolites, which are common surrogate markers in neurological disorders. Copyright © 2017 John Wiley & Sons, Ltd.
Wong Te Fong, Anne-Christine; Hill, Deborah K.; Orton, Matthew R.; Parkes, Harry G.; Koh, Dow-Mu; Robinson, Simon P.; Leach, Martin O.; Eykyn, Thomas R.; Chung, Yuen-Li
2014-01-01
Autophagy is a highly regulated, energy dependent cellular process where proteins, organelles and cytoplasm are sequestered in autophagosomes and digested to sustain cellular homeostasis. We hypothesized that during autophagy induced in cancer cells by i) starvation through serum and amino acid deprivation or ii) treatment with PI-103, a class I PI3K/mTOR inhibitor, glycolytic metabolism would be affected, reducing flux to lactate, and that this effect may be reversible. We probed metabolism during autophagy in colorectal HT29 and HCT116 Bax knock-out cells using hyperpolarized 13C-magnetic resonance spectroscopy (MRS) and steady-state 1H-MRS. 24 hr PI103-treatment or starvation caused significant reduction in the apparent forward rate constant (kPL) for pyruvate to lactate exchange compared with controls in HT29 (100 μM PI-103: 82%, p = 0.05) and HCT116 Bax-ko cells (10 μM PI-103: 53%, p = 0.05; 20 μM PI-103: 42%, p<0.0001; starvation: 52%, p<0.001), associated with reduced lactate excretion and intracellular lactate in all cases, and unchanged lactate dehydrogenase (LDH) activity and increased NAD+/NADH ratio following PI103 treatment or decreased LDH activity and unchanged NAD+/NADH ratio following starvation. After 48 hr recovery from PI103 treatment, kPL remained below control levels in HT29 cells (74%, p = 0.02), and increased above treated values, but remained below 24 hr vehicle-treated control levels in HCT116 Bax-ko cells (65%, p = 0.004) both were accompanied by sustained reduction in lactate excretion, recovery of NAD+/NADH ratio and intracellular lactate. Following recovery from starvation, kPL was significantly higher than 24 hr vehicle-treated controls (140%, p = 0.05), associated with increased LDH activity and total cellular NAD(H). Changes in kPL and cellular and excreted lactate provided measureable indicators of the major metabolic processes accompanying starvation- and drug-induced autophagy. The changes are reversible, returning towards and exceeding control values on cellular recovery, which potentially identifies resistance. kPL (hyperpolarized 13C-MRS) and lactate (1H-MRS) provide useful biomarkers for the autophagic process, enabling non-invasive monitoring of the Warburg effect. PMID:24667972
Kassubek, Jan; Sperfeld, Anne-Dorte; Pinkhardt, Elmar H.; Unrath, Alexander; Müller, Hans-Peter; Scharffetter-Kochanek, Karin; Ludolph, Albert C.; Berneburg, Mark
2012-01-01
Background Xeroderma pigmentosum (XP) is a rare autosomal recessive progeroid syndrome. It has recently been shown that the underlying DNA repair defect plays a central role in the aging process. In addition to skin symptoms, various premature neurological abnormalities have been reported. Methodology/Principal Findings We present the clinical neurological phenotype in 14 XP patients (seven subtypes), in seven of these patients together with conventional and multiparametric advanced MRI data to assess the macrostructural and microstructural cerebral morphology in comparison to controls, including volumetric measurements, MR spectroscopy (1H MRS), and diffusion tensor imaging (DTI). Clinical hallmarks were spinocerebellar ataxia, pyramidal tract signs, and mild cognitive deficits. DTI demonstrated significantly reduced WM directionality in all regions investigated, i.e. the thalamus, the corticospinal tracts and the dorsal corpus callosum. Single patients showed a marked relative hippocampal volume reduction, but the patients were not different from controls in the volumetric measurements of hippocampal and whole brain volumes at group level. However, 1H MRS demonstrated that the hippocampal formation was metabolically altered. Conclusions The most prominent feature was the white matter affectation, as assessed by DTI, with volume and directionality reductions of the fiber projections involving both the craniocaudal fibers and the interhemispheric connections. These findings, although heterogeneous among the study sample, could be correlated with the clinico-neurological symptoms. The imaging findings support the position that myelin structures degrade prematurely in the brain of XP patients. PMID:22363517
ERIC Educational Resources Information Center
Congress of the U.S., Washington, DC. Senate Select Committee on Nutrition and Human Needs.
The following witnesses testified before these hearings of the Select Committee on Nutrition and Human Needs: Mrs. G. Marsh, area consultant, Division of Food and Nutrition Services, Pennsylvania Department of Education; Mrs. G. Chegwidden, director, School Food Service, Franklin Regional School District, Murrysville, Pa.; Mr. S. Lympany, senior…
Mamlin, Burke W; Biondich, Paul G; Wolfe, Ben A; Fraser, Hamish; Jazayeri, Darius; Allen, Christian; Miranda, Justin; Tierney, William M
2006-01-01
Millions of people are continue to die each year from HIV/AIDS. The majority of infected persons (>95%) live in the developing world. A worthy response to this pandemic will require coordinated, scalable, and flexible information systems. We describe the OpenMRS system, an open source, collaborative effort that can serve as a foundation for EMR development in developing countries. We report our progress to date, lessons learned, and future directions.
Elberling, T V; Danielsen, E R; Rasmussen, A K; Feldt-Rasmussen, U; Waldemar, G; Thomsen, C
2003-01-14
Neuropsychiatric symptoms in the acute thyrotoxic phase of Graves' disease suggest involvement of brain processes. Short-echo-time proton MRS was used to measure the cerebral metabolite profile in newly diagnosed and untreated Graves' disease. Sixteen patients with Graves' disease and 18 age- and sex-matched healthy volunteers were studied. The patients had significantly reduced total choline and myo-inositol in the acute phase of Graves' thyrotoxicosis compared with the healthy volunteers.
How Do Separatist Insurgents Use Negotiations for Their Growth and Survival?
2006-06-16
of Cambridge Circle, Kansas City ; and Mr. John and Mrs. Deb Jenson of Leawood, Kansas City , and the great generosity extended to my family by Mr...and Mrs. Channa Mudalige of Lenexa, Kansas City . They gave me courage and strength to have a free mind for conducting a research whilst attending the...by M.A.A.J. Kularatne, MAJ, Sri Lanka Army M Def S, University of Kelaniya, Sri Lanka, 2005 Fort Leavenworth, Kansas 2006
Sandulache, Vlad C; Chen, Yunyun; Lee, Jaehyuk; Rubinstein, Ashley; Ramirez, Marc S; Skinner, Heath D; Walker, Christopher M; Williams, Michelle D; Tailor, Ramesh; Court, Laurence E; Bankson, James A; Lai, Stephen Y
2014-01-01
Ionizing radiation (IR) cytotoxicity is primarily mediated through reactive oxygen species (ROS). Since tumor cells neutralize ROS by utilizing reducing equivalents, we hypothesized that measurements of reducing potential using real-time hyperpolarized (HP) magnetic resonance spectroscopy (MRS) and spectroscopic imaging (MRSI) can serve as a surrogate marker of IR induced ROS. This hypothesis was tested in a pre-clinical model of anaplastic thyroid carcinoma (ATC), an aggressive head and neck malignancy. Human ATC cell lines were utilized to test IR effects on ROS and reducing potential in vitro and [1-¹³C] pyruvate HP-MRS/MRSI imaging of ATC orthotopic xenografts was used to study in vivo effects of IR. IR increased ATC intra-cellular ROS levels resulting in a corresponding decrease in reducing equivalent levels. Exogenous manipulation of cellular ROS and reducing equivalent levels altered ATC radiosensitivity in a predictable manner. Irradiation of ATC xenografts resulted in an acute drop in reducing potential measured using HP-MRS, reflecting the shunting of reducing equivalents towards ROS neutralization. Residual tumor tissue post irradiation demonstrated heterogeneous viability. We have adapted HP-MRS/MRSI to non-invasively measure IR mediated changes in tumor reducing potential in real time. Continued development of this technology could facilitate the development of an adaptive clinical algorithm based on real-time adjustments in IR dose and dose mapping.
Jiménez-Xarrié, Elena; Davila, Myriam; Gil-Perotín, Sara; Jurado-Rodríguez, Andrés; Candiota, Ana Paula; Delgado-Mederos, Raquel; Lope-Piedrafita, Silvia; García-Verdugo, José Manuel; Arús, Carles; Martí-Fàbregas, Joan
2015-01-01
Ex vivo high-resolution magic-angle spinning (HRMAS) provides metabolic information with higher sensitivity and spectral resolution than in vivo magnetic resonance spectroscopy (MRS). Therefore, we used both techniques to better characterize the metabolic pattern of the infarct and the neural progenitor cells (NPCs) in the ipsilateral subventricular zone (SVZi). Ischemic stroke rats were divided into three groups: G0 (non-stroke controls, n=6), G1 (day 1 after stroke, n=6), and G7 (days 6 to 8 after stroke, n=12). All the rats underwent MRS. Three rats per group were analyzed by HRMAS. The remaining rats were used for immunohistochemical studies. In the infarct, both techniques detected significant metabolic changes. The most relevant change was in mobile lipids (2.80 ppm) in the G7 group (a 5.53- and a 3.95-fold increase by MRS and HRMAS, respectively). In the SVZi, MRS did not detect any significant metabolic change. However, HRMAS detected a 2.70-fold increase in lactate and a 0.68-fold decrease in N-acetylaspartate in the G1 group. None of the metabolites correlated with the 1.37-fold increase in NPCs detected by immunohistochemistry in the G7 group. In conclusion, HRMAS improves the metabolic characterization of the brain in experimental ischemic stroke. However, none of the metabolites qualifies as a surrogate biomarker of NPCs. PMID:25605287
Ahn, So Yoon; Yoo, Hye Soo; Lee, Jang Hoon; Sung, Dong Kyung; Jung, Yu Jin; Sung, Se In; Lim, Keun Ho; Chang, Yun Sil; Lee, Jung Hee; Kim, Ki Soo; Park, Won Soon
2013-07-01
This study was performed to determine the accuracy of proton magnetic spectroscopy ((1)H-MRS) lipid peak as a noninvasive tool for quantitative in vivo detection of brain cell death. Seven day-old Sprague Dawley rats were subjected to 8% oxygen following a unilateral carotid artery ligation. For treatment, cycloheximide was given immediately after hypoxic ischemia (HI). Lipid peak was measured using (1)H-MRS at 24 hr after HI, and then brains were harvested for fluorocytometric analyses with annexin V/propidium iodide (PI) and fluorescent probe JC-1, and for adenosine-5'-triphosphate (ATP) and lactate. Increased lipid peak at 1.3 ppm measured with (1)H-MRS, apoptotic and necrotic cells, and loss of mitochondrial membrane potential (ΔΨ) at 24 hr after HI were significantly improved with cycloheximide treatment. Significantly reduced brain ATP and increased lactate levels observed at 24 hr after HI showed a tendency to improve without statistical significance with cycloheximide treatment. Lipid peak at 1.3 ppm showed significant positive correlation with both apoptotic and necrotic cells and loss of ΔΨ, and negative correlation with normal live cells. Lipid peak at 1.3 ppm measured by (1)H-MRS might be a sensitive and reliable diagnostic tool for quantitative in vivo detection of brain cell death after HI.
Licata, Stephanie C.; Renshaw, Perry F.
2011-01-01
Proton magnetic resonance spectroscopy (1H MRS) is a non-invasive imaging technique that permits measurement of particular compounds or metabolites within the tissue of interest. In the brain, 1H MRS provides a snapshot of the neurochemical environment within a defined volume of interest. A search of the literature demonstrates the widespread utility of this technique for characterizing tumors, tracking the progress of neurodegenerative disease, and for understanding the neurobiological basis of psychiatric disorders. As of relatively recently, 1H MRS has found its way into substance abuse research, and it is beginning to become recognized as a valuable complement in the brain imaging toolbox that also contains positron emission tomography (PET), single photon emission computed tomography (SPECT), and functional magnetic resonance imaging (fMRI). Drug abuse studies employing 1H MRS have identified a number biochemical changes in the brain. The most consistent alterations across drug class were reductions in N-acetylaspartate and elevations in myo-inositol, while changes in choline, creatine, and amino acid transmitters also were abundant. Together, the studies discussed herein provide evidence that drugs of abuse may have a profound impact on neuronal health, energy metabolism and maintenance, inflammatory processes, cell membrane turnover, and neurotransmission, and these biochemical changes may underlie the neuropathology within brain tissue that subsequently gives rise to the cognitive and behavioral impairments associated with drug addiction. PMID:20201852
Volk, Carina; Jaramillo, Valeria; Merki, Renato; O'Gorman Tuura, Ruth; Huber, Reto
2018-06-08
The glutamatergic α-amino-3-hydroxy-5-methyl-4-isoxazolepropionic acid (AMPA) receptor is involved in synaptic plasticity processes, and animal studies have demonstrated altered expression across the sleep wake cycle. Accordingly, glutamate levels are reduced during non-rapid eye movement (NREM) sleep and the rate of this decrease is positively correlated with sleep EEG slow wave activity (SWA). Here, we combined proton magnetic resonance spectroscopy ( 1 H-MRS) and high-density sleep EEG to assess if 1 H-MRS is sensitive to diurnal changes of glutamate + glutamine (GLX) in healthy young adults and if potential overnight changes of GLX are correlated to SWA. 1 H-MRS was measured in the parietal lobe in the evening and in the subsequent morning. High-density sleep EEG was recorded overnight between the evening and morning scans. Our results revealed a significant overnight reduction in GLX, but no significant changes in other metabolites. The decrease in GLX positively correlated with the decrease of SWA. Our study demonstrates that quantification of diurnal changes in GLX is possible by means of 1 H-MRS and indicates that overnight changes in GLX are related to SWA, a marker that is closely linked to the restorative function of sleep. This relationship might be of particular interest in clinical populations in which sleep is disturbed. © 2018 Wiley Periodicals, Inc.
Simulation of the hyperspectral data from multispectral data using Python programming language
NASA Astrophysics Data System (ADS)
Tiwari, Varun; Kumar, Vinay; Pandey, Kamal; Ranade, Rigved; Agarwal, Shefali
2016-04-01
Multispectral remote sensing (MRS) sensors have proved their potential in acquiring and retrieving information of Land Use Land (LULC) Cover features in the past few decades. These MRS sensor generally acquire data within limited broad spectral bands i.e. ranging from 3 to 10 number of bands. The limited number of bands and broad spectral bandwidth in MRS sensors becomes a limitation in detailed LULC studies as it is not capable of distinguishing spectrally similar LULC features. On the counterpart, fascinating detailed information available in hyperspectral (HRS) data is spectrally over determined and able to distinguish spectrally similar material of the earth surface. But presently the availability of HRS sensors is limited. This is because of the requirement of sensitive detectors and large storage capability, which makes the acquisition and processing cumbersome and exorbitant. So, there arises a need to utilize the available MRS data for detailed LULC studies. Spectral reconstruction approach is one of the technique used for simulating hyperspectral data from available multispectral data. In the present study, spectral reconstruction approach is utilized for the simulation of hyperspectral data using EO-1 ALI multispectral data. The technique is implemented using python programming language which is open source in nature and possess support for advanced imaging processing libraries and utilities. Over all 70 bands have been simulated and validated using visual interpretation, statistical and classification approach.
Microglia recapitulate a hematopoietic master regulator network in the aging human frontal cortex
Wehrspaun, Claudia C.; Haerty, Wilfried; Ponting, Chris P.
2015-01-01
Microglia form the immune system of the brain. Previous studies in cell cultures and animal models suggest altered activation states and cellular senescence in the aged brain. Instead, we analyzed 3 transcriptome data sets from the postmortem frontal cortex of 381 control individuals to show that microglia gene markers assemble into a transcriptional module in a gene coexpression network. These markers predominantly represented M1 and M1/M2b activation phenotypes. Expression of genes in this module generally declines over the adult life span. This decrease was more pronounced in microglia surface receptors for microglia and/or neuron crosstalk than in markers for activation state phenotypes. In addition to these receptors for exogenous signals, microglia are controlled by brain-expressed regulatory factors. We identified a subnetwork of transcription factors, including RUNX1, IRF8, PU.1, and TAL1, which are master regulators (MRs) for the age-dependent microglia module. The causal contributions of these MRs on the microglia module were verified using publicly available ChIP-Seq data. Interactions of these key MRs were preserved in a protein-protein interaction network. Importantly, these MRs appear to be essential for regulating microglia homeostasis in the adult human frontal cortex in addition to their crucial roles in hematopoiesis and myeloid cell-fate decisions during embryogenesis. PMID:26002684
Lexical access via letter naming in a profoundly alexic and anomic patient: a treatment study.
Greenwald, M L; Gonzalez Rothi, L J
1998-11-01
We report the results of a letter naming treatment designed to facilitate letter-by-letter reading in an aphasic patient with no reading ability. Patient M.R.'s anomia for written letters reflected two loci of impairment within visual naming: impaired letter activation from print (a deficit commonly seen in pure alexic patients who read letter by letter) and impaired access to phonology via semantics (documented in a severe multimodality anomia). Remarkably, M.R. retained an excellent ability to pronounce orally spelled words, demonstrating that abstract letter identities could be activated normally via spoken letter names, and also that lexical phonological representations were intact when accessed via spoken letter names. M.R.'s training in oral naming of written letters resulted in significant improvement in her oral naming of trained letters. Importantly, as M.R.'s letter naming improved, she became able to employ letter-by-letter reading as a compensatory strategy for oral word reading. M.R.'s success in letter naming and letter-by-letter reading suggests that other patients with a similar pattern of spared and impaired cognitive abilities may benefit from a similar treatment. Moreover, this study highlights the value of testing the pronunciation of orally spelled words in localizing the source of prelexical reading impairment and in predicting the functional outcome of treatment for impaired letter activation in reading.
Metabolic profiles of placenta in preeclampsia using HR-MAS MRS metabolomics.
Austdal, Marie; Thomsen, Liv Cecilie Vestrheim; Tangerås, Line Haugstad; Skei, Bente; Mathew, Seema; Bjørge, Line; Austgulen, Rigmor; Bathen, Tone Frost; Iversen, Ann-Charlotte
2015-12-01
Preeclampsia is a heterogeneous gestational disease characterized by maternal hypertension and proteinuria, affecting 2-7% of pregnancies. The disorder is initiated by insufficient placental development, but studies characterizing the placental disease components are lacking. Our aim was to phenotype the preeclamptic placenta using high-resolution magic angle spinning nuclear magnetic resonance spectroscopy (HR-MAS MRS). Placental samples collected after delivery from women with preeclampsia (n = 19) and normotensive pregnancies (n = 15) were analyzed for metabolic biomarkers including amino acids, osmolytes, and components of the energy and phospholipid metabolism. The metabolic biomarkers were correlated to clinical characteristics and inflammatory biomarkers in the maternal sera. Principal component analysis showed inherent differences in placental metabolic profiles between preeclamptic and normotensive pregnancies. Significant differences in metabolic profiles were found between placentas from severe and non-severe preeclampsia, but not between preeclamptic pregnancies with fetal growth restricted versus normal weight neonates. The placental metabolites correlated with the placental stress marker sFlt-1 and triglycerides in maternal serum, suggesting variation in placental stress signaling between different placental phenotypes. HR-MAS MRS is a sensitive method for defining the placental disease component of preeclampsia, identifying several altered metabolic pathways. Placental HR-MAS MRS analysis may improve insight into processes affected in the preeclamptic placenta, and represents a novel long-required tool for a sensitive placental phenotyping of this heterogeneous disease. Copyright © 2015 Elsevier Ltd. All rights reserved.
Development of common neural representations for distinct numerical problems
Chang, Ting-Ting; Rosenberg-Lee, Miriam; Metcalfe, Arron W. S.; Chen, Tianwen; Menon, Vinod
2015-01-01
How the brain develops representations for abstract cognitive problems is a major unaddressed question in neuroscience. Here we tackle this fundamental question using arithmetic problem solving, a cognitive domain important for the development of mathematical reasoning. We first examined whether adults demonstrate common neural representations for addition and subtraction problems, two complementary arithmetic operations that manipulate the same quantities. We then examined how the common neural representations for the two problem types change with development. Whole-brain multivoxel representational similarity (MRS) analysis was conducted to examine common coding of addition and subtraction problems in children and adults. We found that adults exhibited significant levels of MRS between the two problem types, not only in the intra-parietal sulcus (IPS) region of the posterior parietal cortex (PPC), but also in ventral temporal-occipital, anterior temporal and dorsolateral prefrontal cortices. Relative to adults, children showed significantly reduced levels of MRS in these same regions. In contrast, no brain areas showed significantly greater MRS between problem types in children. Our findings provide novel evidence that the emergence of arithmetic problem solving skills from childhood to adulthood is characterized by maturation of common neural representations between distinct numerical operations, and involve distributed brain regions important for representing and manipulating numerical quantity. More broadly, our findings demonstrate that representational analysis provides a powerful approach for uncovering fundamental mechanisms by which children develop proficiencies that are a hallmark of human cognition. PMID:26160287
EFFECT OF INTERFERON-α ON CORTICAL GLUTAMATE IN PATIENTS WITH HEPATITIS C: A PROTON MRS STUDY
Taylor, Matthew J; Godlewska, Beata; Near, Jamie; Christmas, David; Potokar, John; Collier, Jane; Klenerman, Paul; Barnes, Eleanor; Cowen, Philip J
2013-01-01
Background The development of depressive symptomatology is a recognised complication of treatment with the cytokine, interferon-α, and has been seen as supporting inflammatory theories of the pathophysiology of major depression. Major depression has been associated with changes in glutamatergic activity and recent formulations of interferon-induced depression have implicated neurotoxic influences which could also lead to changes in glutamate function. The present study used magnetic resonance spectroscopy (MRS) to measure both glutamate and its major metabolite, glutamine in patients with hepatitis C who received treatment with pegylated-interferon-α and ribavirin. Methods MRS measurements of glutamate and glutamine were taken from a 25×20×20mm voxel including pregenual anterior cingulate cortex in 12 patients before and after 4-6 weeks treatment with interferon. Results Interferon treatment led to an increase in cortical levels of glutamine (p= 0.02) and a significant elevation in the ratio of glutamine to glutamate (p<.01). Further, changes in glutamine level correlated significantly with ratings of depression and anxiety at the time of the second scan. Conclusions We conclude that treatment with interferon-α is associated with MRS-visible changes in glutamatergic metabolism. However, the changes seen differ from those reported in major depression which suggests that the pathophysiology of interferon-induced depression may be distinct from that of major depression more generally. PMID:23659574
Lu, Ming; Zhu, Xiao-Hong; Zhang, Yi; Chen, Wei
2015-01-01
Purpose Nicotinamide adenine dinucleotide (NAD), in oxidized (NAD+) or reduced (NADH) form, plays key roles in cellular metabolism. Intracellular NAD+/NADH ratio represents the cellular redox state; however, it is difficult to measure in vivo. We report here a novel in vivo 31P MRS method for noninvasive measurement of intracellular NAD concentrations and NAD+/NADH ratio in the brain. Methods It uses a theoretical model to describe the NAD spectral patterns at a given field for quantification. Standard NAD solutions and independent cat brain measurements at 9.4 T and 16.4 T were used to evaluate this method. We also measured T1 values of brain NAD. Results Model simulation and studies of solutions and brains indicate that the proposed method can quantify submillimolar NAD concentrations with reasonable accuracy if adequate 31P MRS signal-to-noise ratio and linewidth were obtained. The NAD concentrations and NAD+/NADH ratio of cat brains measured at 16.4 T and 9.4 T were consistent despite the significantly different T1 values and NAD spectra patterns at two fields. Conclusion This newly established 31P MRS method makes it possible for the first time to noninvasively study the intracellular redox state and its roles in brain functions and diseases, and it can potentially be applied to other organs. PMID:23843330
Lin, Yanqin; Lin, Liangjie; Wei, Zhiliang; Zhong, Jianhui; Chen, Zhong
2016-12-01
To acquire single voxel localized one-dimensional 1 H magnetic resonance spectroscopy (MRS) without J coupling modulations, free from amplitude and phase distortions. A pulse sequence, named PRESSIR, is developed for volume localized MRS without J modulations at arbitrary echo time (TE). The J coupling evolution is suppressed by the J-refocused module that uses a 90° pulse at the midpoint of a double spin echo. The localization performance of the PRESSIR sequence was tested with a two-compartment phantom. The proposed sequence shows similar voxel localization accuracy as PRESS. Both PRESSIR and PRESS sequences were performed on MRS brain phantom and pig brain tissue. PRESS spectra suffer from amplitude and phase distortions due to J modulations, especially under moderate and long TEs, while PRESSIR spectra are almost free from distortions. The PRESSIR sequence proposed herein enables the acquisition of single voxel in-phase MRS within a single scan. It allows an enhanced signal intensity of J coupling metabolites and reducing undesired broad resonances with short T2s while suppressing J modulations. Moreover, it provides an approach for direct measurement of nonoverlapping J coupling peaks and of transverse relaxation times T2s. Magn Reson Med 76:1661-1667, 2016. © 2015 International Society for Magnetic Resonance in Medicine. © 2015 International Society for Magnetic Resonance in Medicine.
Einstein, Samuel A; Weegman, Bradley P; Kitzmann, Jennifer P; Papas, Klearchos K; Garwood, Michael
2017-05-01
Transplantation of macroencapsulated tissue-engineered grafts (TEGs) is being investigated as a treatment for type 1 diabetes, but there is a critical need to measure TEG viability both in vitro and in vivo. Oxygen deficiency is the most critical issue preventing widespread implementation of TEG transplantation and delivery of supplemental oxygen (DSO) has been shown to enhance TEG survival and function in vivo. In this study, we demonstrate the first use of oxygen-17 magnetic resonance spectroscopy ( 17 O-MRS) to measure the oxygen consumption rate (OCR) of TEGs and show that in addition to providing therapeutic benefits to TEGs, DSO with 17 O 2 can also enable measurements of TEG viability. Macroencapsulated TEGs containing βTC3 murine insulinoma cells were prepared with three fractional viabilities and provided with 17 O 2 . Cellular metabolism of 17 O 2 into nascent mitochondrial water (H 2 17 O) was monitored by 17 O-MRS and, from the measured data, OCR was calculated. For comparison, OCR was simultaneously measured on a separate, but equivalent sample of cells with a well-established stirred microchamber technique. OCR measured by 17 O-MRS agreed well with measurements made in the stirred microchamber device. These studies confirm that 17 O-MRS can quantify TEG viability noninvasively. Biotechnol. Bioeng. 2017;114: 1118-1121. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Licata, Stephanie C; Renshaw, Perry F
2010-02-01
Proton magnetic resonance spectroscopy ((1)H MRS) is a noninvasive imaging technique that permits measurement of particular compounds or metabolites within the tissue of interest. In the brain, (1)H MRS provides a snapshot of the neurochemical environment within a defined volume of interest. A search of the literature demonstrates the widespread utility of this technique for characterizing tumors, tracking the progress of neurodegenerative disease, and for understanding the neurobiological basis of psychiatric disorders. As of relatively recently, (1)H MRS has found its way into substance abuse research, and it is beginning to become recognized as a valuable complement in the brain imaging toolbox that also contains positron emission tomography, single-photon-emission computed tomography, and functional magnetic resonance imaging. Drug abuse studies using (1)H MRS have identified several biochemical changes in the brain. The most consistent alterations across drug class were reductions in N-acetylaspartate and elevations in myo-inositol, whereas changes in choline, creatine, and amino acid transmitters also were abundant. Together, the studies discussed herein provide evidence that drugs of abuse may have a profound effect on neuronal health, energy metabolism and maintenance, inflammatory processes, cell membrane turnover, and neurotransmission, and these biochemical changes may underlie the neuropathology within brain tissue that subsequently gives rise to the cognitive and behavioral impairments associated with drug addiction.
Occipital cortical proton MRS at 4 Tesla in human moderate MDMA polydrug users
Cowan, Ronald L.; Bolo, Nicolas R.; Dietrich, Mary; Haga, Erica; Lukas, Scott E.; Renshaw, Perry F.
2007-01-01
The recreational drug MDMA (3,4, methylenedioxymethamphetamine; sold under the street name of Ecstasy) is toxic to serotonergic axons in some animal models of MDMA administration. In humans, MDMA use is associated with alterations in markers of brain function that are pronounced in occipital cortex. Among neuroimaging methods, magnetic resonance spectroscopy (MRS) studies of brain metabolites N-acetylaspartate (NAA) and myoinositol (MI) at a field strength of 1.5 Tesla (T) reveal inconsistent results in MDMA users. Because higher field strength proton MRS has theoretical advantages over lower field strengths, we used proton MRS at 4.0 T to study absolute concentrations of occipital cortical NAA and MI in a cohort of moderate MDMA users (n = 9) versus non-MDMA using (n = 7) controls. Mean NAA in non-MDMA users was 10.47 mM (± 2.51), versus 9.83 mM (± 1.94) in MDMA users. Mean MI in non-MDMA users was 7.43 mM (± 1.68), versus 6.57 mM (± 1.59) in MDMA users. There were no statistical differences in absolute metabolite levels for NAA and MI in occipital cortex of MDMA users and controls. These findings are not supportive of MDMA-induced alterations in NAA or MI levels in this small sample of moderate MDMA users. Limitations to this study suggest caution in the interpretation of these results. PMID:17574394
Occipital cortical proton MRS at 4 Tesla in human moderate MDMA polydrug users.
Cowan, Ronald L; Bolo, Nicolas R; Dietrich, Mary; Haga, Erica; Lukas, Scott E; Renshaw, Perry F
2007-08-15
The recreational drug MDMA (3,4, methylenedioxymethamphetamine; sold under the street name of Ecstasy) is toxic to serotonergic axons in some animal models of MDMA administration. In humans, MDMA use is associated with alterations in markers of brain function that are pronounced in occipital cortex. Among neuroimaging methods, magnetic resonance spectroscopy (MRS) studies of brain metabolites N-acetylaspartate (NAA) and myoinositol (MI) at a field strength of 1.5 Tesla (T) reveal inconsistent results in MDMA users. Because higher field strength proton MRS has theoretical advantages over lower field strengths, we used proton MRS at 4.0 T to study absolute concentrations of occipital cortical NAA and MI in a cohort of moderate MDMA users (n=9) versus non-MDMA using (n=7) controls. Mean NAA in non-MDMA users was 10.47 mM (+/-2.51), versus 9.83 mM (+/-1.94) in MDMA users. Mean MI in non-MDMA users was 7.43 mM (+/-.68), versus 6.57 mM (+/-1.59) in MDMA users. There were no statistical differences in absolute metabolite levels for NAA and MI in occipital cortex of MDMA users and controls. These findings are not supportive of MDMA-induced alterations in NAA or MI levels in this small sample of moderate MDMA users. Limitations to this study suggest caution in the interpretation of these results.
Leroy, Frédéric; De Vuyst, Luc
2001-01-01
Although commercial MRS broth has been designed to allow excellent growth of lactobacilli, most of these bacteria are still subjected to a self-inhibiting process. The most likely explanation is the accumulation of lactic acid or other toxic end products and the depletion of nutrients. In this study, the self-inhibition of Lactobacillus sakei CTC 494 was analyzed in a kinetic way, and a nutrient depletion model was set up to describe the growth inhibition process. This simple model has considerable advantages compared to commonly used descriptive models such as the logistic growth equation. It offers a better fit and a more realistic description of the growth data by taking into account both growth inhibition due to lactic acid production and changes in growth rates due to nutrient depletion. Depending on the fermentation conditions, in MRS broth there appears to be a strong decrease of the specific growth rate over time. Some undefined compounds present in the complex nitrogen source of MRS broth appear to be of crucial importance because of their limited availability. Moreover, nutrient availability affects bacteriocin production through its effect on cell growth as well as on the bacteriocin production per cell. A plateau value for the bacteriocin production by L. sakei CTC 494 was observed. PMID:11571136
Brain MRI and MR Spectroscopy Findings in Children with Nutritional Vitamin B12 Deficiency.
Ekici, F; Tekbas, G; Hattapoğlu, S; Yaramış, A; Önder, H; Bilici, A
2016-06-01
Our aim in this study was to analyze the findings of brain magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS) of children with vitamin B12 deficiency. This study included 14 cases. The findings of brain MRI and MRS in all cases were investigated. Four patients had been followed up and mean follow-up time 71.8 (59-85) day. Eight patients of the cases (57 %) had at least one abnormal MRI finding. The most commonly found MRI findings were thinning of the corpus callosum and brain atrophy, respectively. The mean ratio of NAA/Cr and Cho/Cr were measured in MRS, with values of 1.31 ± 0.17 and 1.04 ± 0.27, respectively. In two of three patients with abnormal MRI studies at presentation, subsequent MRI showed improvement while one patient remained unchanged. An increase in the ratios of metabolites were found in one case with control MRS. There was no lactate peak. Brain MRI was abnormal in more than half of the cases of children with vitamin B12 deficiency. Our radiologic findings similar with literature. There was no identifiable lactate peak. B12 deficiency could be the cause of the thinning of the corpus callosum and brain atrophy in the children that were given a brain MRI.
Moon, Chung-Man; Jeong, Gwang-Woo
2016-05-01
Generalized anxiety disorder (GAD) is characterized by emotional dysregulation and cognitive deficit in conjunction with brain morphometric and metabolic alterations. This study assessed the combined neural morphological deficits and metabolic abnormality in patients with GAD. Thirteen patients with GAD and 13 healthy controls matched for age, sex, and education level underwent high-resolution T1-weighted MRI and proton magnetic resonance spectroscopy ((1)H-MRS) at 3Tesla. In this study, the combination of voxel-based morphometry (VBM) and (1)H-MRS was used to assess the brain morphometric and metabolic alterations in GAD. The patients showed significantly reduced white matter (WM) volumes in the midbrain (MB), precentral gyrus (PrG), dorsolateral prefrontal cortex (DLPFC) and anterior limb of the internal capsule (ALIC) compared to the controls. In MRS study, the choline/creatine (Cho/Cr) and choline/N-acetylaspartate (Cho/NAA) ratios in the DLPFC were significantly lower in the patients. Particularly, the WM volume variation of the DLPFC was positively correlated with both of the Cho/Cr and Cho/NAA ratios in patients with GAD. This study provides an evidence for the association between the morphometric deficit and metabolic changes in GAD. This finding would be helpful to understand the neural dysfunction and pathogenesis in connection with cognitive impairments in GAD. Copyright © 2015 Elsevier Inc. All rights reserved.
Lenkinski, Robert E.; Bloch, B. Nicholas; Liu, Fangbing; Frangioni, John V.; Perner, Sven; Rubin, Mark A.; Genega, Elizabeth; Rofsky, Neil M.; Gaston, Sandra M.
2009-01-01
Magnetic resonance imaging (MRI) and MR spectroscopy can probe a variety of physiological (e.g. blood vessel permeability) and metabolic characteristics of prostate cancer. However, little is known about the changes in gene expression that underlie the spectral and imaging features observed in prostate cancer. Tumor induced changes in vascular permeability and angiogenesis are thought to contribute to patterns of dynamic contrast enhanced (DCE) MRI images of prostate cancer even though the genetic basis of tumor vasculogenesis is complex and the specific mechanisms underlying these DCEMRI features have not yet been determined. In order to identify the changes in gene expression that correspond to MRS and DCEMRI patterns in human prostate cancers, we have utilized tissue print micropeel techniques to generate “whole mount” molecular maps of radical prostatectomy specimens that correspond to pre-surgical MRI/MRS studies. These molecular maps include RNA expression profiles from both Affymetrix GeneChip microarrays and quantitative reverse transcriptase PCR (qrt-PCR) analysis, as well as immunohistochemical studies. Using these methods on patients with prostate cancer, we found robust over-expression of choline kinase a in the majority of primary tumors. We also observed overexpression of neuropeptide Y (NPY), a newly identified angiogenic factor, in a subset of DCEMRI positive prostate cancers. These studies set the stage for establishing MRI/MRS parameters as validated biomarkers for human prostate cancer. PMID:18752015
Assessment of multiresolution segmentation for delimiting drumlins in digital elevation models.
Eisank, Clemens; Smith, Mike; Hillier, John
2014-06-01
Mapping or "delimiting" landforms is one of geomorphology's primary tools. Computer-based techniques such as land-surface segmentation allow the emulation of the process of manual landform delineation. Land-surface segmentation exhaustively subdivides a digital elevation model (DEM) into morphometrically-homogeneous irregularly-shaped regions, called terrain segments. Terrain segments can be created from various land-surface parameters (LSP) at multiple scales, and may therefore potentially correspond to the spatial extents of landforms such as drumlins. However, this depends on the segmentation algorithm, the parameterization, and the LSPs. In the present study we assess the widely used multiresolution segmentation (MRS) algorithm for its potential in providing terrain segments which delimit drumlins. Supervised testing was based on five 5-m DEMs that represented a set of 173 synthetic drumlins at random but representative positions in the same landscape. Five LSPs were tested, and four variants were computed for each LSP to assess the impact of median filtering of DEMs, and logarithmic transformation of LSPs. The testing scheme (1) employs MRS to partition each LSP exhaustively into 200 coarser scales of terrain segments by increasing the scale parameter ( SP ), (2) identifies the spatially best matching terrain segment for each reference drumlin, and (3) computes four segmentation accuracy metrics for quantifying the overall spatial match between drumlin segments and reference drumlins. Results of 100 tests showed that MRS tends to perform best on LSPs that are regionally derived from filtered DEMs, and then log-transformed. MRS delineated 97% of the detected drumlins at SP values between 1 and 50. Drumlin delimitation rates with values up to 50% are in line with the success of manual interpretations. Synthetic DEMs are well-suited for assessing landform quantification methods such as MRS, since subjectivity in the reference data is avoided which increases the reliability, validity and applicability of results.
Human in vivo cardiac phosphorus NMR spectroscopy at 3.0 Tesla
NASA Astrophysics Data System (ADS)
Bruner, Angela Properzio
One of the newest methods with great potential for use in clinical diagnosis of heart disease is human, cardiac, phosphorus NMR spectroscopy (cardiac p 31 MRS). Cardiac p31 MRS is able to provide quantitative, non-invasive, functional information about the myocardial energy metabolites such as pH, phosphocreatine (PCr), and adenosinetriphosphate (ATP). In addition to the use of cardiac p3l MRS for other types of cardiac problems, studies have shown that the ratio of PCr/ATP and pH are sensitive and specific markers of ischemia at the myocardial level. In human studies, typically performed at 1.5 Tesla, PCr/ATP has been relatively easy to measure but often requires long scan times to provide adequate signal-to-noise (SNR). In addition, pH which relies on identification of inorganic phosphate (Pi), has rarely been obtained. Significant improvement in the quality of cardiac p31 MRS was achieved through the use of the General Electric SIGNATM 3.0 Tesla whole body magnet, improved coil designs and optimized pulse sequences. Phantom and human studies performed on many types of imaging and spectroscopy sequences, identified breathhold gradient-echo imaging and oblique DRESS p31 spectroscopy as the best compromises between SNR, flexibility and quality localization. Both single-turn and quadrature 10-cm diameter, p31 radiofrequency coils, were tested with the quadrature coil providing greater SNR, but at a greater depth to avoid skeletal muscle contamination. Cardiac p31 MRS obtained in just 6 to 8 minutes, gated, showed both improved SNR and discernment of Pi allowing for pH measurement. A handgrip, in-magnet exerciser was designed, created and tested at 1.5 and 3.0 Tesla on volunteers and patients. In ischemic patients, this exercise was adequate to cause a repeated drop in PCr/ATP and pH with approximately eight minutes of isometric exercise at 30% maximum effort. As expected from literature, this exercise did not cause a drop in PCr/ATP for reference volunteers.
Roda, Elisa; Coccini, Teresa; Acerbi, Davide; Castoldi, Anna; Bernocchi, Graziella; Manzo, Luigi
2008-05-01
The developing central nervous system (CNS) is a target of the environmental toxicant methylmercury (MeHg), and the cerebellum seems the most susceptible tissue in response to this neurotoxicant. The cholinergic system is essential for brain development, acting as a modulator of neuronal proliferation, migration and differentiation processes; its muscarinic receptors (MRs) play pivotal roles in regulating important basic physiologic functions. By immunohistochemistry, we investigated the effects of perinatal (GD7-PD21) MeHg (0.5 mg/kg bw/day in drinking water) administration on cerebellum of mature (PD36) and immature (PD21) rats, evaluating the: (i) M2- and M3-MR expression; (ii) presence of gliosis; (iii) cytoarchitecture alterations. Regarding to M2-MRs, we showed that: at PD21, MeHg-treated animals did not display any differences compared to controls, while, at PD36 there was a significant increase of M2-immunopositive Bergmann cells in the molecular layer (ML), suggesting a MeHg-related cytotoxic effect. Similarly to M2-MRs, at PD21 the M3-MRs were not affected by MeHg, while, at PD36 a lacking immunoreactivity of the granular layer (IGL) was observed after MeHg treatment. In MeHg-treated rats, at both developmental points, we showed reactive gliosis, e.g. a significant increase in Bergmann glia of the ML and astrocytes of the IGL, identified by their expression of glial fibrillar acidic protein. No MeHg-related effects on Purkinje cells were detected neither at weaning nor at puberty. These findings suggest: (i) a delayed MeHg exposure-related effect on M2- and M3-MRs, (ii) an overt MeHg-related cytotoxic effect on cerebellar oligodendroglia, e.g. reactive gliosis, (iii) a selective vulnerability of granule cells and Purkinje neurons to MeHg, with the latter that remain unharmed.
Price, L H; Li, Y; Patel, A; Gyawali, C Prakash
2014-05-01
Multiple rapid swallows (MRS) during esophageal high resolution manometry (HRM) assess esophageal neuromuscular integrity by evaluating postdeglutitive inhibition and rebound contraction, but most reports performed only a single MRS sequence. We assessed patterns of MRS reproducibility during clinical HRM in comparison to a normal cohort. Consecutive clinical HRM studies were included if two separate MRS sequences (four to six rapid swallows ≤4 s apart) were successfully performed. Chicago Classification diagnoses were identified; contraction wave abnormalities were additionally recorded. MRS-induced inhibition (contraction ≤3 cm during inhibition phase) and rebound contraction was assessed, and findings compared to 18 controls (28.0 ± 0.7 year, 50.0% female). Reproducibility consisted of similar inhibition and contraction responses with both sequences; discordance was segregated into inhibition and contraction phases. Multiple rapid swallows were successfully performed in 89.3% patients and all controls; 225 subjects (56.2 ± 0.9 year, 62.7% female) met study inclusion criteria. Multiple rapid swallows were reproducible in 76.9% patients and 94.4% controls (inhibition phase: 88.0% vs 94.4%, contraction phase 86.7% vs 100%, respectively, p = ns). A gradient of reproducibility was noted, highest in well-developed motor disorders (achalasia spectrum, hypermotility disorders, and aperistalsis, 91.7-100%, p = ns compared to controls); and lower in lesser motor disorders (contraction wave abnormalities, esophageal body hypomotility) or normal studies (62.2-70.8%, p < 0.0001 compared to well-developed motor disorders). Inhibition phase was most discordant in contraction wave abnormalities, while contraction phase was most discordant when studies were designated normal. Multiple rapid swallows are highly reproducible, especially in well-developed motor disorders, and complement the standard wet swallow manometry protocol. © 2014 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Valaparla, Sunil K.; Gao, Feng; Abdul-Ghani, Muhammad; Clarke, Geoffrey D.
2014-03-01
When muscle fibers are aligned with the B0 field, intramyocellular lipids (IMCL), important for providing energy during physical activity, can be resolved in proton magnetic resonance spectra (1H-MRS). Various muscles of the leg differ significantly in their proportion of fibers and angular distribution. This study determined the influence of muscle fiber type and orientation on IMCL using 1H-MRS and diffusion tensor imaging (DTI). Muscle fiber orientation relative to B0 was estimated by pennation angle (PA) measurements from DTI, providing orientation-specific extramyocellular lipid (EMCL) chemical shift data that were used for subject-specific IMCL quantification. Vastus lateralis (VL), tibialis anterior (TA) and soleus (SO) muscles of 6 healthy subjects (21-40 yrs) were studied on a Siemens 3T MRI system with a flex 4-channel coil. 1H-MRS were acquired using stimulated echo acquisition mode (STEAM, TR=3s, TE=270ms). DTI was performed using single shot EPI (b=600s/mm2, 30 directions, TR=4.5s, TE=82ms, and ten×5mm slices) with center slice indexed to the MRS voxel. The average PA's measured from ROI analysis of primary eigenvectors were PA=19.46+/-5.43 for unipennate VL, 15.65+/-3.73 for multipennate SO, and 7.04+/-3.34 for bipennate TA. Chemical shift (CS) was calculated using [3cos2θ-1] dependence: 0.17+/-0.02 for VL, 0.18+/-0.01 for SO and 0.19+/-0.004 ppm for TA. IMCL-CH2 concentrations from spectral analysis were 12.77+/-6.3 for VL, 3.07+/-1.63 for SO and 0.27+/-0.08 mmol/kg ww for TA. Small PA's were measured in TA and large CS with clear separation between EMCL and IMCL peaks were observed. Larger variations in PA were measured VL and SO resulting in an increased overlap of the EMCL on IMCL peaks.
Assessment of Acropora palmata in the Mesoamerican Reef System
Rodríguez-Martínez, Rosa E.; Banaszak, Anastazia T.; McField, Melanie D.; Beltrán-Torres, Aurora U.; Álvarez-Filip, Lorenzo
2014-01-01
The once-dominant shallow reef-building coral Acropora palmata has suffered drastic geographical declines in the wider Caribbean from a disease epidemic that began in the late 1970s. At present there is a lack of quantitative data to determine whether this species is recovering over large spatial scales. Here, we use quantitative surveys conducted in 107 shallow-water reef sites between 2010 and 2012 to investigate the current distribution and abundance of A. palmata along the Mesoamerican Reef System (MRS). Using historical data we also explored how the distribution and abundance of this species has changed in the northern portion of the MRS between 1985 and 2010–2012. A. palmata was recorded in only a fifth of the surveyed reef sites in 2010–2012. In the majority of these reef sites the presence of A. palmata was patchy and rare. Only one site (Limones reef), in the northernmost portion of the MRS, presented considerably high A. palmata cover (mean: 34.7%, SD: 24.5%). At this site, the size-frequency distribution of A. palmata colonies was skewed towards small colony sizes; 84% of the colonies were healthy, however disease prevalence increased with colony size. A comparison with historical data showed that in the northern portion of the MRS, in 1985, A. palmata occurred in 74% of the 31 surveyed sites and had a mean cover of 7.7% (SD = 9.0), whereas in 2010–2012 this species was recorded in 48% of the sites with a mean cover of 2.9% (SD = 7.5). A. palmata populations along the MRS are failing to recover the distribution and abundance they had prior to the 1980s. Investigating the biological (e.g., population genetics) and environmental conditions (e.g., sources of stress) of the few standing reefs with relatively high A. palmata cover is crucial for the development of informed restoration models for this species. PMID:24763319
Heba, Elhamy R.; Desai, Ajinkya; Zand, Kevin A.; Hamilton, Gavin; Wolfson, Tanya; Schlein, Alexandra N.; Gamst, Anthony; Loomba, Rohit; Sirlin, Claude B.; Middleton, Michael S.
2016-01-01
Purpose To determine the accuracy and the effect of possible subject-based confounders of magnitude-based magnetic resonance imaging (MRI) for estimating hepatic proton density fat fraction (PDFF) for different numbers of echoes in adults with known or suspected nonalcoholic fatty liver disease, using MR spectroscopy (MRS) as a reference. Materials and Methods In this retrospective analysis of 506 adults, hepatic PDFF was estimated by unenhanced 3.0T MRI, using right-lobe MRS as reference. Regions of interest placed on source images and on six-echo parametric PDFF maps were colocalized to MRS voxel location. Accuracy using different numbers of echoes was assessed by regression and Bland–Altman analysis; slope, intercept, average bias, and R2 were calculated. The effect of age, sex, and body mass index (BMI) on hepatic PDFF accuracy was investigated using multivariate linear regression analyses. Results MRI closely agreed with MRS for all tested methods. For three- to six-echo methods, slope, regression intercept, average bias, and R2 were 1.01–0.99, 0.11–0.62%, 0.24–0.56%, and 0.981–0.982, respectively. Slope was closest to unity for the five-echo method. The two-echo method was least accurate, underestimating PDFF by an average of 2.93%, compared to an average of 0.23–0.69% for the other methods. Statistically significant but clinically nonmeaningful effects on PDFF error were found for subject BMI (P range: 0.0016 to 0.0783), male sex (P range: 0.015 to 0.037), and no statistically significant effect was found for subject age (P range: 0.18–0.24). Conclusion Hepatic magnitude-based MRI PDFF estimates using three, four, five, and six echoes, and six-echo parametric maps are accurate compared to reference MRS values, and that accuracy is not meaningfully confounded by age, sex, or BMI. PMID:26201284
Haufe, William M; Wolfson, Tanya; Hooker, Catherine A; Hooker, Jonathan C; Covarrubias, Yesenia; Schlein, Alex N; Hamilton, Gavin; Middleton, Michael S; Angeles, Jorge E; Hernando, Diego; Reeder, Scott B; Schwimmer, Jeffrey B; Sirlin, Claude B
2017-12-01
To assess and compare the accuracy of magnitude-based magnetic resonance imaging (MRI-M) and complex-based MRI (MRI-C) for estimating hepatic proton density fat fraction (PDFF) in children, using MR spectroscopy (MRS) as the reference standard. A secondary aim was to assess the agreement between MRI-M and MRI-C. This was a HIPAA-compliant, retrospective analysis of data collected in children enrolled in prospective, Institutional Review Board (IRB)-approved studies between 2012 and 2014. Informed consent was obtained from 200 children (ages 8-19 years) who subsequently underwent 3T MR exams that included MRI-M, MRI-C, and T 1 -independent, T 2 -corrected, single-voxel stimulated echo acquisition mode (STEAM) MRS. Both MRI methods acquired six echoes at low flip angles. T2*-corrected PDFF parametric maps were generated. PDFF values were recorded from regions of interest (ROIs) drawn on the maps in each of the nine Couinaud segments and three ROIs colocalized to the MRS voxel location. Regression analyses assessing agreement with MRS were performed to evaluate the accuracy of each MRI method, and Bland-Altman and intraclass correlation coefficient (ICC) analyses were performed to assess agreement between the MRI methods. MRI-M and MRI-C PDFF were accurate relative to the colocalized MRS reference standard, with regression intercepts of 0.63% and -0.07%, slopes of 0.998 and 0.975, and proportion-of-explained-variance values (R 2 ) of 0.982 and 0.979, respectively. For individual Couinaud segments and for the whole liver averages, Bland-Altman biases between MRI-M and MRI-C were small (ranging from 0.04 to 1.11%) and ICCs were high (≥0.978). Both MRI-M and MRI-C accurately estimated hepatic PDFF in children, and high intermethod agreement was observed. 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2017;46:1641-1647. © 2017 International Society for Magnetic Resonance in Medicine.
2011-01-01
Background Traditional magnetic resonance (MR) imaging can identify abnormal changes in ipsilateral thalamus in patients with unilateral middle cerebral artery (MCA) infarcts. However, it is difficult to demonstrate these early changes quantitatively. Diffusion tensor imaging (DTI) and proton magnetic resonance spectroscopy (MRS) are potentially sensitive and quantitative methods of detection in examining changes of tissue microstructure and metabolism. In this study, We used both DTI and MRS to examine possible secondary damage of thalamus in patients with corona radiata infarction. Methods Twelve patients with unilateral corona radiata infarction underwent MR imaging including DTI and MRS at one week (W1), four weeks (W4), and twelve weeks (W12) after onset of stroke. Twelve age-matched controls were imaged. Mean diffusivity (MD), fractional anisotropy (FA), N-acetylaspartate (NAA), choline(Cho), and creatine(Cr) were measured in thalami. Results T1-weighted fluid attenuation inversion recovery (FLAIR), T2-weighted, and T2-FLAIR imaging showed an infarct at unilateral corona radiate but no other lesion in each patient brain. In patients, MD was significantly increased at W12, compared to W1 and W4 (all P< 0.05). NAA was significantly decreased at W4 compared to W1, and at W12 compared to W4 (all P< 0.05) in the ipsilateral thalamus. There was no significant change in FA, Cho, or Cr in the ipsilateral thalamus from W1 to W12. Spearman's rank correlation analysis revealed a significant negative correlation between MD and the peak area of NAA, Cho, and Cr at W1, W4, and W12 and a significant positive correlation of FA with NAA at W1. Conclusions These findings indicate that DTI and MRS can detect the early changes indicating secondary damage in the ipsilateral thalamus after unilateral corona radiata infarction. MRS may reveal the progressive course of damage in the ipsilateral thalamus over time. PMID:21542942
Tollard, Eléonore; Galanaud, Damien; Perlbarg, Vincent; Sanchez-Pena, Paola; Le Fur, Yann; Abdennour, Lamine; Cozzone, Patrick; Lehericy, Stéphane; Chiras, Jacques; Puybasset, Louis
2009-04-01
The objective of the study is to test whether multimodal magnetic resonance imaging can provide a reliable outcome prediction of the clinical status, focusing on consciousness at 1 year after severe traumatic brain injury (TBI). Single center prospective cohort with consecutive inclusions. Critical Care Neurosurgical Unit of a university hospital. Forty-three TBI patients not responding to simple orders after sedation cessation and 15 healthy controls. A multimodal magnetic resonance imaging combining morphologic sequences, diffusion tensor imaging (DTI), and H proton magnetic resonance spectroscopy (MRS) was performed 24 +/- 11 days after severe TBI. The ability of DTI and MRS to predict 1-year outcome was assessed by linear discriminant analysis (LDA). Robustness of the classification was tested using a bootstrap procedure. Fractional anisotropy (FA) was computed as the mean of values at discrete brain sites in the infratentorial and supratentorial regions. The N-acetyl aspartate/creatine (NAA/Cr) ratio was measured in the thalamus, lenticular nucleus, insular cortex, occipital periventricular white matter, and pons. After 1 year, 19 (44%) patients had unfavorable outcomes (death, persistent vegetative state, or minimally conscious state) and 24 (56%) favorable outcomes (normal consciousness with or without functional impairments). Analysis of variance was performed to compare FA and NAA/Cr in the two outcome groups and controls. FA and MRS findings showed highly significant differences between the outcome groups, with significant variables by LDA being supratentorial FA, NAA/Cr (pons), NAA/Cr (thalamus), NAA/Cr (insula), and infratentorial FA. LDA of combined FA and MRS data clearly separated the unfavorable outcome, favorable outcome, and control groups, with no overlap. Unfavorable outcome was predicted with up to 86% sensitivity and 97% specificity; these values were better than those obtained with DTI or MRS alone. FA and NAA/Cr hold potential as quantitative outcome-prediction tools at the subacute phase of TBI.
Validating a Predictive Model of Acute Advanced Imaging Biomarkers in Ischemic Stroke.
Bivard, Andrew; Levi, Christopher; Lin, Longting; Cheng, Xin; Aviv, Richard; Spratt, Neil J; Lou, Min; Kleinig, Tim; O'Brien, Billy; Butcher, Kenneth; Zhang, Jingfen; Jannes, Jim; Dong, Qiang; Parsons, Mark
2017-03-01
Advanced imaging to identify tissue pathophysiology may provide more accurate prognostication than the clinical measures used currently in stroke. This study aimed to derive and validate a predictive model for functional outcome based on acute clinical and advanced imaging measures. A database of prospectively collected sub-4.5 hour patients with ischemic stroke being assessed for thrombolysis from 5 centers who had computed tomographic perfusion and computed tomographic angiography before a treatment decision was assessed. Individual variable cut points were derived from a classification and regression tree analysis. The optimal cut points for each assessment variable were then used in a backward logic regression to predict modified Rankin scale (mRS) score of 0 to 1 and 5 to 6. The variables remaining in the models were then assessed using a receiver operating characteristic curve analysis. Overall, 1519 patients were included in the study, 635 in the derivation cohort and 884 in the validation cohort. The model was highly accurate at predicting mRS score of 0 to 1 in all patients considered for thrombolysis therapy (area under the curve [AUC] 0.91), those who were treated (AUC 0.88) and those with recanalization (AUC 0.89). Next, the model was highly accurate at predicting mRS score of 5 to 6 in all patients considered for thrombolysis therapy (AUC 0.91), those who were treated (0.89) and those with recanalization (AUC 0.91). The odds ratio of thrombolysed patients who met the model criteria achieving mRS score of 0 to 1 was 17.89 (4.59-36.35, P <0.001) and for mRS score of 5 to 6 was 8.23 (2.57-26.97, P <0.001). This study has derived and validated a highly accurate model at predicting patient outcome after ischemic stroke. © 2017 American Heart Association, Inc.
Method for Controlled Mitochondrial Perturbation during Phosphorus MRS in Children
Cree-Green, Melanie; Newcomer, Bradley R.; Brown, Mark; Hull, Amber; West, Amy D.; Singel, Debra; Reusch, Jane E.B.; McFann, Kim; Regensteiner, Judith G.; Nadeau, Kristen J.
2014-01-01
Introduction Insulin resistance (IR) is increasingly prevalent in children, and may be related to muscle mitochondrial dysfunction, necessitating development of mitochondrial assessment techniques. Recent studies used 31Phosphorus magnetic resonance spectroscopy (31P-MRS), a non-invasive technique appealing for clinical research. 31P-MRS requires exercise at a precise percentage of maximum volitional contraction (MVC). MVC measurement in children, particularly with disease, is problematic due to variability in perception of effort and motivation. We therefore developed a method to predict MVC, using maximal calf muscle cross-sectional area (MCSA) to assure controlled and reproducible muscle metabolic perturbations. Methods Data were collected from 66 sedentary 12–20 year-olds. Plantar flexion-volitional MVC was assessed using a MRI-compatible exercise treadle device. MCSA of the calf muscles were measured from MRI images. Data from the first 26 participants were utilized to model the relationship between MVC and MCSA (predicted MVC = 24.763+0.0047*MCSA). This model was then applied to the subsequent 40 participants. Results Volitional vs. model-predicted mean MVC was 43.9±0.8 kg vs. 44.2±1.81 (P=0.90). 31P-MRS results when predicted and volitional MVC were similar showed expected changes during volitional MVC-based exercise. In contrast, volitional MVC was markedly lower than predicted in 4 participants, and produced minimal metabolic perturbation. Upon repeat testing, these individuals could perform their predicted MVC with coaching, which produced expected metabolic perturbations. Conclusions Compared to using MVC testing alone, utilizing MRI to predict muscle strength allows for a more accurate and standardized 31P-MRS protocol during exercise in children. This method overcomes a major obstacle in assessing mitochondrial function in youth. These studies have importance as we seek to determine the role of mitochondrial function in youth with IR and diabetes and response to interventions. PMID:24576856
Ecklund, Kirsten; Vajapeyam, Sridhar; Mulkern, Robert V; Feldman, Henry A; O'Donnell, Jennifer M; DiVasta, Amy D; Gordon, Catherine M
2017-07-01
Adolescents and women with anorexia nervosa have increased bone marrow fat and decreased bone formation, at least in part due to hormonal changes leading to preferential stem cell differentiation to adipocytes over osteoblasts. The purpose of this study was to evaluate marrow fat content and correlate with age and disease severity using knee MRI with T1 relaxometry (T1-R) and MR spectroscopy (MRS) in 70 adolescents with anorexia nervosa. We enrolled 70 girls with anorexia nervosa who underwent 3-T knee MRI with coronal T1-W images, T1-R and single-voxel proton MRS at 30 and 60 ms TE. Metaphyses were scored visually on the T1-W images for red marrow. Visual T1 score, T1 relaxometry values, MRS lipid indices and fat fractions were analyzed by regression on age, body mass index (BMI) and bone mineral density (BMD) as disease severity markers. MRS measures included unsaturated fat index, T2 water, unsaturated and saturated fat fractions. All red marrow measures declined significantly with age. T1-R values were associated negatively with BMI and BMD for girls ≤16 years (P=0.03 and P=0.002, respectively) and positively for those≥17 years (P=0.05 and P=0.003, respectively). MRS identified a strong inverse association between T2 water and saturated fat fraction from 60 ms TE data (r=-0.85, P<0.0001). There was no association between unsaturated fat index and BMI or BMD. The association between T1 and BMI and BMD among older girls suggests more marrow fat in those with severe anorexia nervosa. In contrast, the physiological association between marrow fat content and age remained dominant in younger patients. The strong association between T2 water and saturated fat may relate to the restricted mobility of water with increasing marrow fat.
Schür, Remmelt R; Draisma, Luc W R; Wijnen, Jannie P; Boks, Marco P; Koevoets, Martijn G J C; Joëls, Marian; Klomp, Dennis W; Kahn, René S; Vinkers, Christiaan H
2016-09-01
The inhibitory gamma-aminobutyric acid (GABA) system is involved in the etiology of most psychiatric disorders, including schizophrenia, autism spectrum disorder (ASD) and major depressive disorder (MDD). It is therefore not surprising that proton magnetic resonance spectroscopy ((1) H-MRS) is increasingly used to investigate in vivo brain GABA levels. However, integration of the evidence for altered in vivo GABA levels across psychiatric disorders is lacking. We therefore systematically searched the clinical (1) H-MRS literature and performed a meta-analysis. A total of 40 studies (N = 1,591) in seven different psychiatric disorders were included in the meta-analysis: MDD (N = 437), schizophrenia (N = 517), ASD (N = 150), bipolar disorder (N = 129), panic disorder (N = 81), posttraumatic stress disorder (PTSD) (N = 104), and attention deficit/hyperactivity disorder (ADHD) (N = 173). Brain GABA levels were lower in ASD (standardized mean difference [SMD] = -0.74, P = 0.001) and in depressed MDD patients (SMD = -0.52, P = 0.005), but not in remitted MDD patients (SMD = -0.24, P = 0.310) compared with controls. In schizophrenia this finding did not reach statistical significance (SMD = -0.23, P = 0.089). No significant differences in GABA levels were found in bipolar disorder, panic disorder, PTSD, and ADHD compared with controls. In conclusion, this meta-analysis provided evidence for lower brain GABA levels in ASD and in depressed (but not remitted) MDD patients compared with healthy controls. Findings in schizophrenia were more equivocal. Even though future (1) H-MRS studies could greatly benefit from a longitudinal design and consensus on the preferred analytical approach, it is apparent that (1) H-MRS studies have great potential in advancing our understanding of the role of the GABA system in the pathogenesis of psychiatric disorders. Hum Brain Mapp 37:3337-3352, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.