Sample records for usable frequency range

  1. EEG-based usability assessment of 3D shutter glasses

    NASA Astrophysics Data System (ADS)

    Wenzel, Markus A.; Schultze-Kraft, Rafael; Meinecke, Frank C.; Cardinaux, Fabien; Kemp, Thomas; Müller, Klaus-Robert; Curio, Gabriel; Blankertz, Benjamin

    2016-02-01

    Objective. Neurotechnology can contribute to the usability assessment of products by providing objective measures of neural workload and can uncover usability impediments that are not consciously perceived by test persons. In this study, the neural processing effort imposed on the viewer of 3D television by shutter glasses was quantified as a function of shutter frequency. In particular, we sought to determine the critical shutter frequency at which the ‘neural flicker’ vanishes, such that visual fatigue due to this additional neural effort can be prevented by increasing the frequency of the system. Approach. Twenty-three participants viewed an image through 3D shutter glasses, while multichannel electroencephalogram (EEG) was recorded. In total ten shutter frequencies were employed, selected individually for each participant to cover the range below, at and above the threshold of flicker perception. The source of the neural flicker correlate was extracted using independent component analysis and the flicker impact on the visual cortex was quantified by decoding the state of the shutter from the EEG. Main Result. Effects of the shutter glasses were traced in the EEG up to around 67 Hz—about 20 Hz over the flicker perception threshold—and vanished at the subsequent frequency level of 77 Hz. Significance. The impact of the shutter glasses on the visual cortex can be detected by neurotechnology even when a flicker is not reported by the participants. Potential impact. Increasing the shutter frequency from the usual 50 Hz or 60 Hz to 77 Hz reduces the risk of visual fatigue and thus improves shutter-glass-based 3D usability.

  2. EEG-based usability assessment of 3D shutter glasses.

    PubMed

    Wenzel, Markus A; Schultze-Kraft, Rafael; Meinecke, Frank C; Fabien Cardinaux; Kemp, Thomas; Klaus-Robert Müller; Gabriel Curio; Benjamin Blankertz

    2016-02-01

    Neurotechnology can contribute to the usability assessment of products by providing objective measures of neural workload and can uncover usability impediments that are not consciously perceived by test persons. In this study, the neural processing effort imposed on the viewer of 3D television by shutter glasses was quantified as a function of shutter frequency. In particular, we sought to determine the critical shutter frequency at which the 'neural flicker' vanishes, such that visual fatigue due to this additional neural effort can be prevented by increasing the frequency of the system. Twenty-three participants viewed an image through 3D shutter glasses, while multichannel electroencephalogram (EEG) was recorded. In total ten shutter frequencies were employed, selected individually for each participant to cover the range below, at and above the threshold of flicker perception. The source of the neural flicker correlate was extracted using independent component analysis and the flicker impact on the visual cortex was quantified by decoding the state of the shutter from the EEG. Effects of the shutter glasses were traced in the EEG up to around 67 Hz-about 20 Hz over the flicker perception threshold-and vanished at the subsequent frequency level of 77 Hz. The impact of the shutter glasses on the visual cortex can be detected by neurotechnology even when a flicker is not reported by the participants. Potential impact. Increasing the shutter frequency from the usual 50 Hz or 60 Hz to 77 Hz reduces the risk of visual fatigue and thus improves shutter-glass-based 3D usability.

  3. Multifrequency measurements of core-diffracted P waves (Pdiff) for global waveform tomography

    NASA Astrophysics Data System (ADS)

    Hosseini, Kasra; Sigloch, Karin

    2015-10-01

    The lower third of the mantle is sampled extensively by body waves that diffract around the earth's core (Pdiff and Sdiff phases), which could deliver highly resolved tomographic images of this poorly understood region. But core-diffracted waves-especially Pdiff waves-are not often used in tomography because they are difficult to model adequately. Our aim is to make core-diffracted body waves usable for global waveform tomography, across their entire frequency range. Here we present the data processing part of this effort. A method is demonstrated that routinely calculates finite-frequency traveltimes of Pdiff waves by cross-correlating large quantities of waveform data with synthetic seismograms, in frequency passbands ranging from 30.0 to 2.7 s dominant period. Green's functions for 1857 earthquakes, typically comprising thousands of seismograms, are calculated by theoretically exact wave propagation through a spherically symmetric earth model, up to 1 Hz dominant period. Out of 418 226 candidates, 165 651 (39.6 per cent) source-receiver pairs yielded at least one successful passband measurement of a Pdiff traveltime anomaly, for a total of 479 559 traveltimes in the eight passbands considered. Measurements of teleseismic P waves yielded 448 178 usable source-receiver paths from 613 057 candidates (73.1 per cent success rate), for a total of 2 306 755 usable teleseismic dT in eight passbands. Observed and predicted characteristics of Pdiff traveltimes are discussed and compared to teleseismic P for this very large data set. Pdiff measurements are noise-limited due to severe wave attenuation with epicentral distance and frequency. Measurement success drops from 40-60 per cent at 80° distance, to 5-10 per cent at 140°. Frequency has a 2-3 times stronger influence on measurement success for Pdiff than for P. The fewest usable dT measurements are obtained in the microseismic noise band, whereas the fewest usable teleseismic P measurements occur at the highest frequencies. dT anomalies are larger for Pdiff than for P, and frequency dependence of dT due to 3-D heterogeneity (rather than just diffraction) is larger for Pdiff as well. Projecting the Pdiff traveltime anomalies on their core-grazing segments, we retrieve well-known, large-scale structural heterogeneities of the lowermost mantle, such as the two Large Low Shear Velocity Provinces, an Ultra-Low Velocity Zone west of Hawaii, and subducted slab accumulations under East Asia and Central America.

  4. Usability and feasibility of mobile phone diaries in an experimental physical exercise study.

    PubMed

    Heinonen, Reetta; Luoto, Riitta; Lindfors, Pirjo; Nygård, Clas-Håkan

    2012-03-01

    Wireless and mobile phone technology as a method of data collection will increase alongside conventional methods. The aim of the present study was to evaluate the use of a mobile phone application for recording symptoms and physical activity exertion during an experimental physical exercise study. An experimental study on the effects of physical exercise on the well-being of menopausal women included 158 subjects between 44 and 63 years of age. The women were randomized into intervention and control groups. All participants in both groups reported daily symptoms by responding to morning and evening questionnaires via mobile phones. The usability of the mobile phone as a data collector tool was evaluated with the System Usability Scale (SUS) questionnaire 2 months after the intervention. The feasibility evaluation was based on the frequency of responses and open questions. The response rates were about 70% to both morning and evening questionnaires. The average frequency of responses (n =158) to morning questionnaires was 125 (±40)/170 (±14) and to evening questionnaires was 118 (±40)/171 (±14). The response rate did not differ between the intervention and the control groups. The SUS score was on average 75.4 (range, 0-100; n =107). A mobile phone diary is a feasible and usable tool for data collection in clinical trials.

  5. The use of fault reporting of medical equipment to identify latent design flaws.

    PubMed

    Flewwelling, C J; Easty, A C; Vicente, K J; Cafazzo, J A

    2014-10-01

    Poor device design that fails to adequately account for user needs, cognition, and behavior is often responsible for use errors resulting in adverse events. This poor device design is also often latent, and could be responsible for "No Fault Found" (NFF) reporting, in which medical devices sent for repair by clinical users are found to be operating as intended. Unresolved NFF reports may contribute to incident under reporting, clinical user frustration, and biomedical engineering technologist inefficacy. This study uses human factors engineering methods to investigate the relationship between NFF reporting frequency and device usability. An analysis of medical equipment maintenance data was conducted to identify devices with a high NFF reporting frequency. Subsequently, semi-structured interviews and heuristic evaluations were performed in order to identify potential usability issues. Finally, usability testing was conducted in order to validate that latent usability related design faults result in a higher frequency of NFF reporting. The analysis of medical equipment maintenance data identified six devices with a high NFF reporting frequency. Semi-structured interviews, heuristic evaluations and usability testing revealed that usability issues caused a significant portion of the NFF reports. Other factors suspected to contribute to increased NFF reporting include accessory issues, intermittent faults and environmental issues. Usability testing conducted on three of the devices revealed 23 latent usability related design faults. These findings demonstrate that latent usability related design faults manifest themselves as an increase in NFF reporting and that devices containing usability related design faults can be identified through an analysis of medical equipment maintenance data. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.

  6. Investigation of Chinese text entry performance for mobile display interfaces.

    PubMed

    Lin, Po-Hung

    2015-01-01

    This study examined the effects of panel type, frequency of use and arrangement of phonetic symbols on operation time, usability, visual fatigue and workload in text entry performance. Three types of panel (solid, touch and mixed), three types of frequency of use (low, medium and high) and two types of the arrangement of phonetic symbols (vertical and horizontal) were investigated through 30 college students in the experiment. The results indicated that panel type, frequency of use, arrangement of phonetic symbols and the interaction between panel type and frequency of use were significant factors on operation time. Panel type was also a significant factor on usability, and a touch panel and a solid panel showed better usability than a mixed panel. Furthermore, a touch panel showed good usability and the lowest workload and therefore it is recommended to use a touch panel with vertical phonetic arrangement in sending Chinese text messages. Practitioner Summary: This study found, from ergonomics considerations, that a touch panel showed good usability and it is recommended to use a touch panel with vertical phonetic arrangement in sending Chinese text messages. Mobile display manufacturers can use the results of this study as a reference for future keyboard design.

  7. Usability evaluation with mental health professionals and young people to develop an Internet-based cognitive-behaviour therapy program for adolescents with anxiety disorders.

    PubMed

    Wozney, Lori; Baxter, Pamela; Newton, Amanda S

    2015-12-16

    Use of the Internet to deliver cognitive behavioural therapy, a frontline treatment for anxiety disorders, is emerging as an option to increase access to treatment among adolescents with anxiety disorders. This study examined the usability of the Internet-based component of Breathe, a CBT program designed for adolescents with mild to moderate anxiety and impairments. A mixed-method usability testing design with semi-structured interviews, task completion, and survey by trained usability moderators was undertaken with two interactive cycles to determine the usability (ease of use, efficiency, errors, and user satisfaction) of the user interface and content areas of the program. Purposeful sampling was used to recruit mental health clinicians with expertise in treating adolescent anxiety disorders and young people aged 15 to 24 years involved. Testing involved using Web-conferencing software that allowed remote participation through personal computers. Two testing cycles involved participants completing structured 'think aloud' and 'cognitive walkthrough' tasks within the program. At the end of each cycle participants completed a 15-item global usability evaluation survey and were asked a series of open-ended questions. Descriptive and simple content analyses were used to identify and score usability issues for frequency and severity. Five clinicians and four young people (all < 20 years of age) participated. Most participants described their computer skills as 'good' (60% clinicians, 50% young people), and attitudes toward Internet-based health care ranged from negative (75% young people) to positive (60% clinicians, 25% young people). Scores from the global usability evaluation after both testing cycles ranged from 3.5 to 5 out of 5 in strong agreement/support of the program in terms of user performance indicators (i.e., learnability, efficiency and number of errors) and user satisfaction. Participants were able to complete all critical tasks with minimal errors. Errors and issues identified during testing were predominantly around enhancements to the visual design and navigational support. Opinions across usability elements did not differ between young people and clinician participants. A multi-method remote usability approach provided the opportunity to improve the technical interface, therapeutic messaging and user experience of an Internet-based treatment program for adolescent anxiety disorders.

  8. Design guidelines for interactive multimedia learning environments to promote social inclusion.

    PubMed

    Brown, D J; Powell, H M; Battersby, S; Lewis, J; Shopland, N; Yazdanparast, M

    There is a continuing need for guidelines to aid in the design of Interactive Multimedia Learning Environments (IMLE) to promote effective learning. The project introduced in this paper looks at an important subset of this problem, the design of interactive learning environments to promote social inclusion. A consortium of six partners contributed toward defining learning material to develop a range of work based skills, including horticulture, IT and catering. These were then developed into IMLE prototypes. Formative evaluation of these prototypes then revealed a range of usability problems, which were grouped into generic types and frequency of occurrence. The most important and frequently occurring problems were used to distil a set of design guidelines for the development of effective IMLE. The results from this usability content analysis were also used to refine the initial prototypes to improve their usability and effectiveness. These guidelines, termed the Greenhat Design Guidelines, can be adopted for use by all multimedia developers aiming to promote the social inclusion of vulnerable or socially disadvantaged groups of people. The refined IMLE can be accessed via the Greenhat Server to improve the employment-related skills of socially excluded people.

  9. Usability evaluation of an emergency department information system prototype designed using cognitive systems engineering techniques.

    PubMed

    Clark, Lindsey N; Benda, Natalie C; Hegde, Sudeep; McGeorge, Nicolette M; Guarrera-Schick, Theresa K; Hettinger, A Zachary; LaVergne, David T; Perry, Shawna J; Wears, Robert L; Fairbanks, Rollin J; Bisantz, Ann M

    2017-04-01

    This article presents an evaluation of novel display concepts for an emergency department information system (EDIS) designed using cognitive systems engineering methods. EDISs assist emergency medicine staff with tracking patient care and ED resource allocation. Participants performed patient planning and orientation tasks using the EDIS displays and rated the display's ability to support various cognitive performance objectives along with the usability, usefulness, and predicted frequency of use for 18 system components. Mean ratings were positive for cognitive performance support objectives, usability, usefulness, and frequency of use, demonstrating the successful application of design methods to create useful and usable EDIS concepts that provide cognitive support for emergency medicine staff. Nurse and provider roles had significantly different perceptions of the usability and usefulness of certain EDIS components, suggesting that they have different information needs while working. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Usability evaluation of an emergency department information system prototype designed using cognitive systems engineering techniques

    PubMed Central

    Clark, Lindsey N.; Benda, Natalie C.; Hegde, Sudeep; McGeorge, Nicolette M.; Guarrera-Schick, Theresa K.; Hettinger, A. Zachary; LaVergne, David T.; Perry, Shawna J.; Wears, Robert L.; Fairbanks, Rollin J.; Bisantz, Ann M.

    2017-01-01

    This article presents an evaluation of novel display concepts for an emergency department information system (EDIS) designed using cognitive systems engineering methods. EDISs assist emergency medicine staff with tracking patient care and ED resource allocation. Participants performed patient planning and orientation tasks using the EDIS displays and rated the display’s ability to support various cognitive performance objectives along with the usability, usefulness, and predicted frequency of use for 18 system components. Mean ratings were positive for cognitive performance support objectives, usability, usefulness, and frequency of use, demonstrating the successful application of design methods to create useful and usable EDIS concepts that provide cognitive support for emergency medicine staff. Nurse and provider roles had significantly different perceptions of the usability and usefulness of certain EDIS components, suggesting that they have different information needs while working. PMID:28166896

  11. Frequency adjustable MEMS vibration energy harvester

    NASA Astrophysics Data System (ADS)

    Podder, P.; Constantinou, P.; Amann, A.; Roy, S.

    2016-10-01

    Ambient mechanical vibrations offer an attractive solution for powering the wireless sensor nodes of the emerging “Internet-of-Things”. However, the wide-ranging variability of the ambient vibration frequencies pose a significant challenge to the efficient transduction of vibration into usable electrical energy. This work reports the development of a MEMS electromagnetic vibration energy harvester where the resonance frequency of the oscillator can be adjusted or tuned to adapt to the ambient vibrational frequency. Micro-fabricated silicon spring and double layer planar micro-coils along with sintered NdFeB micro-magnets are used to construct the electromagnetic transduction mechanism. Furthermore, another NdFeB magnet is adjustably assembled to induce variable magnetic interaction with the transducing magnet, leading to significant change in the spring stiffness and resonance frequency. Finite element analysis and numerical simulations exhibit substantial frequency tuning range (25% of natural resonance frequency) by appropriate adjustment of the repulsive magnetic interaction between the tuning and transducing magnet pair. This demonstrated method of frequency adjustment or tuning have potential applications in other MEMS vibration energy harvesters and micromechanical oscillators.

  12. Usability study of a computer-based self-management system for older adults with chronic diseases.

    PubMed

    Or, Calvin; Tao, Da

    2012-11-08

    Usability can influence patients' acceptance and adoption of a health information technology. However, little research has been conducted to study the usability of a self-management health care system, especially one geared toward elderly patients. This usability study evaluated a new computer-based self-management system interface for older adults with chronic diseases, using a paper prototype approach. Fifty older adults with different chronic diseases participated. Two usability evaluation methods were involved: (1) a heuristics evaluation and (2) end-user testing with a think-aloud testing method, audio recording, videotaping, and interviewing. A set of usability metrics was employed to determine the overall system usability, including task incompletion rate, task completion time, frequency of error, frequency of help, satisfaction, perceived usefulness, and perceived ease of use. Interviews were used to elicit participants' comments on the system design. The quantitative data were analyzed using descriptive statistics and the qualitative data were analyzed for content. The participants were able to perform the predesigned self-management tasks with the current system design and they expressed mostly positive responses about the perceived usability measures regarding the system interface. However, the heuristics evaluation, performance measures, and interviews revealed a number of usability problems related to system navigation, information search and interpretation, information presentation, and readability. Design recommendations for further system interface modifications were discussed. This study verified the usability of the self-management system developed for older adults with chronic diseases. Also, we demonstrated that our usability evaluation approach could be used to quickly and effectively identify usability problems in a health care information system at an early stage of the system development process using a paper prototype. Conducting a usability evaluation is an essential step in system development to ensure that the system features match the users' true needs, expectations, and characteristics, and also to minimize the likelihood of the users committing user errors and having difficulties using the system.

  13. Usability Study of a Computer-Based Self-Management System for Older Adults with Chronic Diseases

    PubMed Central

    Tao, Da

    2012-01-01

    Background Usability can influence patients’ acceptance and adoption of a health information technology. However, little research has been conducted to study the usability of a self-management health care system, especially one geared toward elderly patients. Objective This usability study evaluated a new computer-based self-management system interface for older adults with chronic diseases, using a paper prototype approach. Methods Fifty older adults with different chronic diseases participated. Two usability evaluation methods were involved: (1) a heuristics evaluation and (2) end-user testing with a think-aloud testing method, audio recording, videotaping, and interviewing. A set of usability metrics was employed to determine the overall system usability, including task incompletion rate, task completion time, frequency of error, frequency of help, satisfaction, perceived usefulness, and perceived ease of use. Interviews were used to elicit participants’ comments on the system design. The quantitative data were analyzed using descriptive statistics and the qualitative data were analyzed for content. Results The participants were able to perform the predesigned self-management tasks with the current system design and they expressed mostly positive responses about the perceived usability measures regarding the system interface. However, the heuristics evaluation, performance measures, and interviews revealed a number of usability problems related to system navigation, information search and interpretation, information presentation, and readability. Design recommendations for further system interface modifications were discussed. Conclusions This study verified the usability of the self-management system developed for older adults with chronic diseases. Also, we demonstrated that our usability evaluation approach could be used to quickly and effectively identify usability problems in a health care information system at an early stage of the system development process using a paper prototype. Conducting a usability evaluation is an essential step in system development to ensure that the system features match the users’ true needs, expectations, and characteristics, and also to minimize the likelihood of the users committing user errors and having difficulties using the system. PMID:23612015

  14. Broadband linear high-voltage amplifier for radio frequency ion traps.

    PubMed

    Kuhlicke, Alexander; Palis, Klaus; Benson, Oliver

    2014-11-01

    We developed a linear high-voltage amplifier for small capacitive loads consisting of a high-voltage power supply and a transistor amplifier. With this cost-effective circuit including only standard parts sinusoidal signals with a few volts can be amplified to 1.7 kVpp over a usable frequency range at large-signal response spanning four orders of magnitude from 20 Hz to 100 kHz under a load of 10 pF. For smaller output voltages the maximum frequency shifts up to megahertz. We test different capacitive loads to probe the influence on the performance. The presented amplifier is sustained short-circuit proof on the output side, which is a significant advantage over other amplifier concepts. The amplifier can be used to drive radio frequency ion traps for single charged nano- and microparticles, which will be presented in brief.

  15. Wireless power transfer exploring spin rectification and inverse spin Hall effects

    NASA Astrophysics Data System (ADS)

    Seeger, R. L.; Garcia, W. J. S.; Dugato, D. A.; da Silva, R. B.; Harres, A.

    2018-04-01

    Devices based on spin rectification effects are of great interest for broadband communication applications, since they allow the rectification of radio frequency signals by simple ferromagnetic materials. The phenomenon is enhanced at ferromagnetic resonance condition, which may be attained when an external magnetic field is applied. The necessity of such field, however, hinders technological applications. Exploring spin rectification and spin Hall effects in exchange-biased samples, we were able to rectify radio frequency signals without an external applied magnetic field. Direct voltages of the order of μV were obtained when Ta/NiFe/FeMn/Ta thin films were exposed to microwaves in a shorted microstrip line for a relatively broad frequency range. Connecting the films to a resistive load, we estimated the fraction of the incident radio frequency power converted into usable dc power.

  16. Usability and clinical efficacy of diabetes mobile applications for adults with type 2 diabetes: A systematic review.

    PubMed

    Fu, Helen; McMahon, Siobhan K; Gross, Cynthia R; Adam, Terrence J; Wyman, Jean F

    2017-09-01

    To assess the usability and clinical effectiveness of diabetes mobile applications (diabetes apps) developed for adults with type 2 diabetes. A systematic review of the usability and effectiveness of diabetes apps was conducted. Searches were performed using MEDLINE, EMBASE, COMPENDEX, and IEEE XPLORE for articles published from January 1, 2011, to January 17, 2017. Search terms included: diabetes, mobile apps, and mobile health (mHealth). The search yielded 723 abstracts of which seven usability studies and ten clinical effectiveness studies met the inclusion criteria from 20 publications. Usability, as measured by satisfaction ratings from experts and patients, ranged from 38% to 80%. Usability problem ratings ranged from moderate to catastrophic. Top usability problems are multi-steps task, limited functionality and interaction, and difficult system navigation. Clinical effectiveness, measured by reductions in HbA1c, ranged from 0.15% to 1.9%. Despite meager satisfaction ratings and major usability problems, there is some limited evidence supporting the effectiveness of diabetes apps to improve glycemic control for adults with type 2 diabetes. Findings strongly suggest that efforts to improve user satisfaction, incorporate established principles of health behavior change, and match apps to user characteristics will increase the therapeutic impact of diabetes apps. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Human Factors in the Large: Experiences from Denmark, Finland and Canada in Moving Towards Regional and National Evaluations of Health Information System Usability. Contribution of the IMIA Human Factors Working Group.

    PubMed

    Kushniruk, A; Kaipio, J; Nieminen, M; Hyppönen, H; Lääveri, T; Nohr, C; Kanstrup, A M; Berg Christiansen, M; Kuo, M-H; Borycki, E

    2014-08-15

    The objective of this paper is to explore approaches to understanding the usability of health information systems at regional and national levels. Several different methods are discussed in case studies from Denmark, Finland and Canada. They range from small scale qualitative studies involving usability testing of systems to larger scale national level questionnaire studies aimed at assessing the use and usability of health information systems by entire groups of health professionals. It was found that regional and national usability studies can complement smaller scale usability studies, and that they are needed in order to understand larger trends regarding system usability. Despite adoption of EHRs, many health professionals rate the usability of the systems as low. A range of usability issues have been noted when data is collected on a large scale through use of widely distributed questionnaires and websites designed to monitor user perceptions of usability. As health information systems are deployed on a widespread basis, studies that examine systems used regionally or nationally are required. In addition, collection of large scale data on the usability of specific IT products is needed in order to complement smaller scale studies of specific systems.

  18. Human Factors in the Large: Experiences from Denmark, Finland and Canada in Moving Towards Regional and National Evaluations of Health Information System Usability

    PubMed Central

    Kaipio, J.; Nieminen, M.; Hyppönen, H.; Lääveri, T.; Nohr, C.; Kanstrup, A. M.; Berg Christiansen, M.; Kuo, M.-H.; Borycki, E.

    2014-01-01

    Summary Objectives The objective of this paper is to explore approaches to understanding the usability of health information systems at regional and national levels. Methods Several different methods are discussed in case studies from Denmark, Finland and Canada. They range from small scale qualitative studies involving usability testing of systems to larger scale national level questionnaire studies aimed at assessing the use and usability of health information systems by entire groups of health professionals. Results It was found that regional and national usability studies can complement smaller scale usability studies, and that they are needed in order to understand larger trends regarding system usability. Despite adoption of EHRs, many health professionals rate the usability of the systems as low. A range of usability issues have been noted when data is collected on a large scale through use of widely distributed questionnaires and websites designed to monitor user perceptions of usability. Conclusion As health information systems are deployed on a widespread basis, studies that examine systems used regionally or nationally are required. In addition, collection of large scale data on the usability of specific IT products is needed in order to complement smaller scale studies of specific systems. PMID:25123725

  19. 5 CFR 532.241 - Analysis of usable wage survey data.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... average rates identified and computed under paragraph (a) of this section. (ii) The frequency payline... PREVAILING RATE SYSTEMS Prevailing Rate Determinations § 532.241 Analysis of usable wage survey data. (a)(1) The lead agency shall compute a weighted average rate for each appropriated fund survey job having at...

  20. Highly efficient frequency conversion with bandwidth compression of quantum light

    PubMed Central

    Allgaier, Markus; Ansari, Vahid; Sansoni, Linda; Eigner, Christof; Quiring, Viktor; Ricken, Raimund; Harder, Georg; Brecht, Benjamin; Silberhorn, Christine

    2017-01-01

    Hybrid quantum networks rely on efficient interfacing of dissimilar quantum nodes, as elements based on parametric downconversion sources, quantum dots, colour centres or atoms are fundamentally different in their frequencies and bandwidths. Although pulse manipulation has been demonstrated in very different systems, to date no interface exists that provides both an efficient bandwidth compression and a substantial frequency translation at the same time. Here we demonstrate an engineered sum-frequency-conversion process in lithium niobate that achieves both goals. We convert pure photons at telecom wavelengths to the visible range while compressing the bandwidth by a factor of 7.47 under preservation of non-classical photon-number statistics. We achieve internal conversion efficiencies of 61.5%, significantly outperforming spectral filtering for bandwidth compression. Our system thus makes the connection between previously incompatible quantum systems as a step towards usable quantum networks. PMID:28134242

  1. Ten factors to consider when developing usability scenarios and tasks for health information technology.

    PubMed

    Russ, Alissa L; Saleem, Jason J

    2018-02-01

    The quality of usability testing is highly dependent upon the associated usability scenarios. To promote usability testing as part of electronic health record (EHR) certification, the Office of the National Coordinator (ONC) for Health Information Technology requires that vendors test specific capabilities of EHRs with clinical end-users and report their usability testing process - including the test scenarios used - along with the results. The ONC outlines basic expectations for usability testing, but there is little guidance in usability texts or scientific literature on how to develop usability scenarios for healthcare applications. The objective of this article is to outline key factors to consider when developing usability scenarios and tasks to evaluate computer-interface based health information technologies. To achieve this goal, we draw upon a decade of our experience conducting usability tests with a variety of healthcare applications and a wide range of end-users, to include healthcare professionals as well as patients. We discuss 10 key factors that influence scenario development: objectives of usability testing; roles of end-user(s); target performance goals; evaluation time constraints; clinical focus; fidelity; scenario-related bias and confounders; embedded probes; minimize risks to end-users; and healthcare related outcome measures. For each factor, we present an illustrative example. This article is intended to aid usability researchers and practitioners in their efforts to advance health information technologies. The article provides broad guidance on usability scenario development and can be applied to a wide range of clinical information systems and applications. Published by Elsevier Inc.

  2. Usability of Computerized Lung Auscultation-Sound Software (CLASS) for learning pulmonary auscultation.

    PubMed

    Machado, Ana; Oliveira, Ana; Jácome, Cristina; Pereira, Marco; Moreira, José; Rodrigues, João; Aparício, José; Jesus, Luis M T; Marques, Alda

    2018-04-01

    The mastering of pulmonary auscultation requires complex acoustic skills. Computer-assisted learning tools (CALTs) have potential to enhance the learning of these skills; however, few have been developed for this purpose and do not integrate all the required features. Thus, this study aimed to assess the usability of a new CALT for learning pulmonary auscultation. Computerized Lung Auscultation-Sound Software (CLASS) usability was assessed by eight physiotherapy students using computer screen recordings, think-aloud reports, and facial expressions. Time spent in each task, frequency of messages and facial expressions, number of clicks and problems reported were counted. The timelines of the three methods used were matched/synchronized and analyzed. The tasks exercises and annotation of respiratory sounds were the ones requiring more clicks (median 132, interquartile range [23-157]; 93 [53-155]; 91 [65-104], respectively) and where most errors (19; 37; 15%, respectively) and problems (n = 7; 6; 3, respectively) were reported. Each participant reported a median of 6 problems, with a total of 14 different problems found, mainly related with CLASS functionalities (50%). Smile was the only facial expression presented in all tasks (n = 54). CLASS is the only CALT available that meets all the required features for learning pulmonary auscultation. The combination of the three usability methods identified advantages/disadvantages of CLASS and offered guidance for future developments, namely in annotations and exercises. This will allow the improvement of CLASS and enhance students' activities for learning pulmonary auscultation skills.

  3. Evaluation of Home Health Care Devices: Remote Usability Assessment.

    PubMed

    Kortum, Philip; Peres, S Camille

    2015-06-05

    An increasing amount of health care is now performed in a home setting, away from the hospital. While there is growing anecdotal evidence about the difficulty patients and caregivers have using increasingly complex health care devices in the home, there has been little systematic scientific study to quantify the global nature of home health care device usability in the field. Research has tended to focus on a handful of devices, making it difficult to gain a broad view of the usability of home-care devices in general. The objective of this paper is to describe a remote usability assessment method using the System Usability Scale (SUS), and to report on the usability of a broad range of health care devices using this metric. A total of 271 participants selected and rated up to 10 home health care devices of their choice using the SUS, which scores usability from 0 (unusable) to 100 (highly usable). Participants rated a total of 455 devices in their own home without an experimenter present. Usability scores ranged from 98 (oxygen masks) to 59 (home hormone test kits). An analysis conducted on devices that had at least 10 ratings showed that the effect of device on SUS scores was significant (P<.001), and that the usability of these devices was on the low end when compared with other commonly used items in the home, such as microwave ovens and telephones. A large database of usability scores for home health care devices collected using this remote methodology would be beneficial for physicians, patients, and their caregivers.

  4. Usability in the real world: assessing medical information technologies in patients' homes.

    PubMed

    Kaufman, David R; Patel, Vimla L; Hilliman, Charlyn; Morin, Philip C; Pevzner, Jenia; Weinstock, Ruth S; Goland, Robin; Shea, Steven; Starren, Justin

    2003-01-01

    This paper presents an approach to usability evaluation of computer-based health care systems designed for patient use in their homes. Although such devices are becoming more prevalent, there is very little known about their usability. The theoretical foundations for the methods are discussed. The approach incorporates a cognitive walkthrough usability evaluation and new methods for usability testing that can be conducted in patient's homes. The method was applied to the IDEATel intervention, a multi-institution randomized controlled trial of the feasibility, acceptability, and clinical utility of a home-based telemedicine system for diabetic Medicare population. The usability study was designed to assess barriers to optimal use of the system. The focus was both on dimensions of the interface and on dimensions of patient skills and competency. The usability field research involved testing 25 patients in their homes using the system. The analysis included a range of video-analytic methods of varying levels of granularity. The usability evaluation revealed aspects of the interface that were sub-optimal and impeded the performance of certain tasks. It also found a range of patient-related factors such as numeracy and psychomotor skills that constituted barriers to productive use. A multifaceted usability approach provided important insight regarding use of technology by an elderly chronic-care patient population and more generally, for understanding how home health initiatives can more effectively use such technology.

  5. Noise-based body-wave seismic tomography in an active underground mine.

    NASA Astrophysics Data System (ADS)

    Olivier, G.; Brenguier, F.; Campillo, M.; Lynch, R.; Roux, P.

    2014-12-01

    Over the last decade, ambient noise tomography has become increasingly popular to image the earth's upper crust. The seismic noise recorded in the earth's crust is dominated by surface waves emanating from the interaction of the ocean with the solid earth. These surface waves are low frequency in nature ( < 1 Hz) and not usable for imaging smaller structures associated with mining or oil and gas applications. The seismic noise recorded at higher frequencies are typically from anthropogenic sources, which are short lived, spatially unstable and not well suited for constructing seismic Green's functions between sensors with conventional cross-correlation methods. To examine the use of ambient noise tomography for smaller scale applications, continuous data were recorded for 5 months in an active underground mine in Sweden located more than 1km below surface with 18 high frequency seismic sensors. A wide variety of broadband (10 - 3000 Hz) seismic noise sources are present in an active underground mine ranging from drilling, scraping, trucks, ore crushers and ventilation fans. Some of these sources generate favorable seismic noise, while others are peaked in frequency and not usable. In this presentation, I will show that the noise generated by mining activity can be useful if periods of seismic noise are carefully selected. Although noise sources are not temporally stable and not evenly distributed around the sensor array, good estimates of the seismic Green's functions between sensors can be retrieved for a broad frequency range (20 - 400 Hz) when a selective stacking scheme is used. For frequencies below 100 Hz, the reconstructed Green's functions show clear body-wave arrivals for almost all of the 153 sensor pairs. The arrival times of these body-waves are picked and used to image the local velocity structure. The resulting 3-dimensional image shows a high velocity structure that overlaps with a known ore-body. The material properties of the ore-body differ from the host rock and is likely the cause of the observed high velocity structure. For frequencies above 200 Hz, the seismic waves are multiply scattered by the tunnels and excavations and used to determine the scattering properties of the medium. The results of this study should be useful for future imaging and exploration projects in mining and oil and gas industries.

  6. 47 CFR 87.303 - Frequencies.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... telecommand operations for flight testing of aircraft and missiles, or their major components. The bands 2310... expendable and re-usable launch vehicles, whether or not such operations involve flight testing: 2364.5, 2370... Flight Test Stations § 87.303 Frequencies. (a) These frequencies are available for assignment to flight...

  7. Usability evaluation of the interactive Personal Patient Profile-Prostate decision support system with African American men.

    PubMed

    Jaja, Cheedy; Pares-Avila, Jose; Wolpin, Seth; Berry, Donna

    2010-04-01

    The Personal Patient Profile-Prostate (P4) program is an interactive Web-based decision support system that provides men with localized prostate cancer customized education and coaching with which to make the best personal treatment decision. This study assessed functionality and usability of the P4 program and identified problems in user-computer interaction in a sample of African American men. Usability testing was conducted with 12 community-dwelling African American adult men. The health status of participants was not known or collected by the research team. Each participant worked with the P4 program and provided simultaneous feedback using the "think aloud" technique. Handwritten field notes were collated and assigned to 3 standard coded categories. Aspects of P4 program usability was made based on common issues in the assigned categories. Summary statistics were derived for types and frequency of usability issues noted in the coded data. Twelve participants reported a total of 122 usability comments, with a mean of 9 usability comments. The most common usability issue by participant was completeness of information content, which comprised 53 (43%) of the total issues. Comprehensibility of text and graphics was second, comprising 51 (42%) of the total issues. This study provided initial inventory of usability issues for community African American men that may potentially interfere with application of the P4 system in the community setting and overall system usability, confirming the need for usability testing of a culturally appropriate Internet-based decision support system before community application.

  8. Microprocessor controlled proof-mass actuator

    NASA Technical Reports Server (NTRS)

    Horner, Garnett C.

    1987-01-01

    The objective of the microprocessor controlled proof-mass actuator is to develop the capability to mount a small programmable device on laboratory models. This capability will allow research in the active control of flexible structures. The approach in developing the actuator will be to mount all components as a single unit. All sensors, electronic and control devices will be mounted with the actuator. The goal for the force output capability of the actuator will be one pound force. The programmable force actuator developed has approximately a one pound force capability over the usable frequency range, which is above 2 Hz.

  9. Usability evaluation of mobile applications; where do we stand?

    NASA Astrophysics Data System (ADS)

    Zahra, Fatima; Hussain, Azham; Mohd, Haslina

    2017-10-01

    The range and availability of mobile applications is expanding rapidly. With the increased processing power available on portable devices, developers are increasing the range of services by embracing smartphones in their extensive and diverse practices. While usability testing and evaluations of mobile applications have not yet touched the accuracy level of other web based applications. The existing usability models do not adequately capture the complexities of interacting with applications on a mobile platform. Therefore, this study aims to presents review on existing usability models for mobile applications. These models are in their infancy but with time and more research they may eventually be adopted. Moreover, different categories of mobile apps (medical, entertainment, education) possess different functional and non-functional requirements thus customized models are required for diverse mobile applications.

  10. Evaluation of expert system application based on usability aspects

    NASA Astrophysics Data System (ADS)

    Munaiseche, C. P. C.; Liando, O. E. S.

    2016-04-01

    Usability usually defined as a point of human acceptance to a product or a system based on understands and right reaction to an interface. The performance of web application has been influence by the quality of the interface of that web to supporting information transfer process. Preferably, before the applications of expert systems were installed in the operational environment, these applications must be evaluated first by usability testing. This research aimed to measure the usability of the expert system application using tasks as interaction media. This study uses an expert system application to diagnose skin disease in human using questionnaire method which utilize the tasks as interaction media in measuring the usability. Certain tasks were executed by the participants in observing usability value of the application. The usability aspects observed were learnability, efficiency, memorability, errors, and satisfaction. Each questionnaire question represent aspects of usability. The results present the usability value for each aspect and the total average merit for all the five-usability aspect was 4.28, this indicated that the tested expert system application is in the range excellent for the usability level, so the application can be implemented as the operated system by user. The main contribution of the study is the research became the first step in using task model in the usability evaluation for the expert system application software.

  11. Effect of improving the usability of an e-learning resource: a randomized trial.

    PubMed

    Davids, Mogamat Razeen; Chikte, Usuf M E; Halperin, Mitchell L

    2014-06-01

    Optimizing the usability of e-learning materials is necessary to reduce extraneous cognitive load and maximize their potential educational impact. However, this is often neglected, especially when time and other resources are limited. We conducted a randomized trial to investigate whether a usability evaluation of our multimedia e-learning resource, followed by fixing of all problems identified, would translate into improvements in usability parameters and learning by medical residents. Two iterations of our e-learning resource [version 1 (V1) and version 2 (V2)] were compared. V1 was the first fully functional version and V2 was the revised version after all identified usability problems were addressed. Residents in internal medicine and anesthesiology were randomly assigned to one of the versions. Usability was evaluated by having participants complete a user satisfaction questionnaire and by recording and analyzing their interactions with the application. The effect on learning was assessed by questions designed to test the retention and transfer of knowledge. Participants reported high levels of satisfaction with both versions, with good ratings on the System Usability Scale and adjective rating scale. In contrast, analysis of video recordings revealed significant differences in the occurrence of serious usability problems between the two versions, in particular in the interactive HandsOn case with its treatment simulation, where there was a median of five serious problem instances (range: 0-50) recorded per participant for V1 and zero instances (range: 0-1) for V2 (P < 0.001). There were no differences in tests of retention or transfer of knowledge between the two versions. In conclusion, usability evaluation followed by a redesign of our e-learning resource resulted in significant improvements in usability. This is likely to translate into improved motivation and willingness to engage with the learning material. In this population of relatively high-knowledge participants, learning scores were similar across the two versions. Copyright © 2014 The American Physiological Society.

  12. Effect of improving the usability of an e-learning resource: a randomized trial

    PubMed Central

    Chikte, Usuf M. E.; Halperin, Mitchell L.

    2014-01-01

    Optimizing the usability of e-learning materials is necessary to reduce extraneous cognitive load and maximize their potential educational impact. However, this is often neglected, especially when time and other resources are limited. We conducted a randomized trial to investigate whether a usability evaluation of our multimedia e-learning resource, followed by fixing of all problems identified, would translate into improvements in usability parameters and learning by medical residents. Two iterations of our e-learning resource [version 1 (V1) and version 2 (V2)] were compared. V1 was the first fully functional version and V2 was the revised version after all identified usability problems were addressed. Residents in internal medicine and anesthesiology were randomly assigned to one of the versions. Usability was evaluated by having participants complete a user satisfaction questionnaire and by recording and analyzing their interactions with the application. The effect on learning was assessed by questions designed to test the retention and transfer of knowledge. Participants reported high levels of satisfaction with both versions, with good ratings on the System Usability Scale and adjective rating scale. In contrast, analysis of video recordings revealed significant differences in the occurrence of serious usability problems between the two versions, in particular in the interactive HandsOn case with its treatment simulation, where there was a median of five serious problem instances (range: 0–50) recorded per participant for V1 and zero instances (range: 0–1) for V2 (P < 0.001). There were no differences in tests of retention or transfer of knowledge between the two versions. In conclusion, usability evaluation followed by a redesign of our e-learning resource resulted in significant improvements in usability. This is likely to translate into improved motivation and willingness to engage with the learning material. In this population of relatively high-knowledge participants, learning scores were similar across the two versions. PMID:24913451

  13. Post-deployment usability evaluation of a radiology workstation.

    PubMed

    Jorritsma, Wiard; Cnossen, Fokie; Dierckx, Rudi A; Oudkerk, Matthijs; Van Ooijen, Peter M A

    2016-01-01

    To determine the number, nature and severity of usability issues radiologists encounter while using a commercially available radiology workstation in clinical practice, and to assess how well the results of a pre-deployment usability evaluation of this workstation generalize to clinical practice. The usability evaluation consisted of semi-structured interviews and observations of twelve users using the workstation during their daily work. Usability issues and positive usability findings were documented. Each issue was given a severity rating and its root cause was determined. Results were compared to the results of a pre-deployment usability evaluation of the same workstation. Ninety-two usability issues were identified, ranging from issues that cause minor frustration or delay, to issues that cause significant delays, prevent users from completing tasks, or even pose a potential threat to patient safety. The results of the pre-deployment usability evaluation had limited generalizability to clinical practice. This study showed that radiologists encountered a large number and a wide variety of usability issues when using a commercially available radiology workstation in clinical practice. This underlines the need for effective usability engineering in radiology. Given the limitations of pre-deployment usability evaluation in radiology, which were confirmed by our finding that the results of a pre-deployment usability evaluation of this workstation had limited generalizability to clinical practice, it is vital that radiology workstation vendors devote significant resources to usability engineering efforts before deployment of their workstation, and to continue these efforts after the workstation is deployed in a hospital. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  14. An Iterative, Mixed Usability Approach Applied to the Telekit System from the Danish TeleCare North Trial

    PubMed Central

    Schaarup, Clara; Hejlesen, Ole Kristian

    2016-01-01

    Objective. The aim of the present study is to evaluate the usability of the telehealth system, coined Telekit, by using an iterative, mixed usability approach. Materials and Methods. Ten double experts participated in two heuristic evaluations (HE1, HE2), and 11 COPD patients attended two think-aloud tests. The double experts identified usability violations and classified them into Jakob Nielsen's heuristics. These violations were then translated into measurable values on a scale of 0 to 4 indicating degree of severity. In the think-aloud tests, COPD participants were invited to verbalise their thoughts. Results. The double experts identified 86 usability violations in HE1 and 101 usability violations in HE2. The majority of the violations were rated in the 0–2 range. The findings from the think-aloud tests resulted in 12 themes and associated examples regarding the usability of the Telekit system. The use of the iterative, mixed usability approach produced both quantitative and qualitative results. Conclusion. The iterative, mixed usability approach yields a strong result owing to the high number of problems identified in the tests because the double experts and the COPD participants focus on different aspects of Telekit's usability. This trial is registered with Clinicaltrials.gov, NCT01984840, November 14, 2013. PMID:27974888

  15. An Iterative, Mixed Usability Approach Applied to the Telekit System from the Danish TeleCare North Trial.

    PubMed

    Lilholt, Pernille Heyckendorff; Schaarup, Clara; Hejlesen, Ole Kristian

    2016-01-01

    Objective . The aim of the present study is to evaluate the usability of the telehealth system, coined Telekit, by using an iterative, mixed usability approach. Materials and Methods . Ten double experts participated in two heuristic evaluations (HE1, HE2), and 11 COPD patients attended two think-aloud tests. The double experts identified usability violations and classified them into Jakob Nielsen's heuristics. These violations were then translated into measurable values on a scale of 0 to 4 indicating degree of severity. In the think-aloud tests, COPD participants were invited to verbalise their thoughts. Results . The double experts identified 86 usability violations in HE1 and 101 usability violations in HE2. The majority of the violations were rated in the 0-2 range. The findings from the think-aloud tests resulted in 12 themes and associated examples regarding the usability of the Telekit system. The use of the iterative, mixed usability approach produced both quantitative and qualitative results. Conclusion . The iterative, mixed usability approach yields a strong result owing to the high number of problems identified in the tests because the double experts and the COPD participants focus on different aspects of Telekit's usability. This trial is registered with Clinicaltrials.gov, NCT01984840, November 14, 2013.

  16. A Web-Based Graphical Food Frequency Assessment System: Design, Development and Usability Metrics.

    PubMed

    Franco, Rodrigo Zenun; Alawadhi, Balqees; Fallaize, Rosalind; Lovegrove, Julie A; Hwang, Faustina

    2017-05-08

    Food frequency questionnaires (FFQs) are well established in the nutrition field, but there remain important questions around how to develop online tools in a way that can facilitate wider uptake. Also, FFQ user acceptance and evaluation have not been investigated extensively. This paper presents a Web-based graphical food frequency assessment system that addresses challenges of reproducibility, scalability, mobile friendliness, security, and usability and also presents the utilization metrics and user feedback from a deployment study. The application design employs a single-page application Web architecture with back-end services (database, authentication, and authorization) provided by Google Firebase's free plan. Its design and responsiveness take advantage of the Bootstrap framework. The FFQ was deployed in Kuwait as part of the EatWellQ8 study during 2016. The EatWellQ8 FFQ contains 146 food items (including drinks). Participants were recruited in Kuwait without financial incentive. Completion time was based on browser timestamps and usability was measured using the System Usability Scale (SUS), scoring between 0 and 100. Products with a SUS higher than 70 are considered to be good. A total of 235 participants created accounts in the system, and 163 completed the FFQ. Of those 163 participants, 142 reported their gender (93 female, 49 male) and 144 reported their date of birth (mean age of 35 years, range from 18-65 years). The mean completion time for all FFQs (n=163), excluding periods of interruption, was 14.2 minutes (95% CI 13.3-15.1 minutes). Female participants (n=93) completed in 14.1 minutes (95% CI 12.9-15.3 minutes) and male participants (n=49) completed in 14.3 minutes (95% CI 12.6-15.9 minutes). Participants using laptops or desktops (n=69) completed the FFQ in an average of 13.9 minutes (95% CI 12.6-15.1 minutes) and participants using smartphones or tablets (n=91) completed in an average of 14.5 minutes (95% CI 13.2-15.8 minutes). The median SUS score (n=141) was 75.0 (interquartile range [IQR] 12.5), and 84% of the participants who completed the SUS classified the system either "good" (n=50) or "excellent" (n=69). Considering only participants using smartphones or tablets (n=80), the median score was 72.5 (IQR 12.5), slightly below the SUS median for desktops and laptops (n=58), which was 75.0 (IQR 12.5). No significant differences were found between genders or age groups (below and above the median) for the SUS or completion time. Taking into account all the requirements, the deployment used professional cloud computing at no cost, and the resulting system had good user acceptance. The results for smartphones/tablets were comparable with desktops/laptops. This work has potential to promote wider uptake of online tools that can assess dietary intake at scale. ©Rodrigo Zenun Franco, Balqees Alawadhi, Rosalind Fallaize, Julie A Lovegrove, Faustina Hwang. Originally published in JMIR Human Factors (http://humanfactors.jmir.org), 08.05.2017.

  17. Usability of Low-Cost Android Data Collection System for Community-Based Participatory Research.

    PubMed

    Salihu, Hamisu M; Salinas-Miranda, Abraham; Turner, DeAnne; King, Lindsey; Paothong, Arnut; Austin, Deborah; Berry, Estrellita Lo

    2016-01-01

    Android tablet computers can be valuable tools for data collection, but their usability has not been evaluated in community-based participatory research (CBPR). This article examines the usability of a low-cost bilingual touchscreen computerized survey system using Android tablets, piloted with a sample of 201 community residents in Tampa, Florida, from November 2013 to March 2014. Needs assessment questions were designed with the droidSURVEY software, and deployed using Android tablet computers. In addition, participants were asked questions about system usability. The mean system usability was 77.57 ± 17.66 (range, 0-100). The mean completion time for taking the 63 survey questions in the needs assessment was 23.11 ± 9.62 minutes. The survey completion rate was optimal (100%), with only 6.34% missingness per variable. We found no sociodemographic differences in usability scores. Our findings indicate that Android tablets could serve as useful tools in CBPR studies.

  18. Advancement of wave generation and signal transmission in wire waveguides for structural health monitoring applications

    NASA Astrophysics Data System (ADS)

    Kropf, M.; Pedrick, M.; Wang, X.; Tittmann, B. R.

    2005-05-01

    As per the recent advances in remote in situ monitoring of industrial equipment using long wire waveguides (~10m), novel applications of existing wave generation techniques and new acoustic modeling software have been used to advance waveguide technology. The amount of attainable information from an acoustic signal in such a system is limited by transmission through the waveguide along with frequency content of the generated waves. Magnetostrictive, and Electromagnetic generation techniques were investigated in order to maximize acoustic transmission along the waveguide and broaden the range of usable frequencies. Commercial EMAT, Magnetostrictive and piezoelectric disc transducers (through the innovative use of an acoustic horn) were utilized to generate waves in the wire waveguide. Insertion loss, frequency bandwidth and frequency range were examined for each technique. Electromagnetic techniques are shown to allow for higher frequency wave generation. This increases accessibility of dispersion curves providing further versatility in the selection of guided wave modes, thus increasing the sensitivity to physical characteristics of the specimen. Both electromagnetic and magnetostrictive transducers require the use of a ferromagnetic waveguide, typically coupled to a steel wire when considering long transmission lines (>2m). The interface between these wires introduces an acoustic transmission loss. Coupling designs were examined with acoustic finite element software (Coupled-Acoustic Piezoelectric Analysis). Simulations along with experimental results aided in the design of a novel joint which minimizes transmission loss. These advances result in the increased capability of remote sensing using wire waveguides.

  19. A usability evaluation of four commercial dental computer-based patient record systems

    PubMed Central

    Thyvalikakath, Thankam P.; Monaco, Valerie; Thambuganipalle, Hima Bindu; Schleyer, Titus

    2008-01-01

    Background The usability of dental computer-based patient record (CPR) systems has not been studied, despite early evidence that poor usability is a problem for dental CPR system users at multiple levels. Methods The authors conducted formal usability tests of four dental CPR systems by using a purposive sample of four groups of five novice users. The authors measured task outcomes (correctly completed, incorrectly completed and incomplete) in each CPR system while the participants performed nine clinical documentation tasks, as well as the number of usability problems identified in each CPR system and their potential relationship to task outcomes. The authors reviewed the software application design aspects responsible for these usability problems. Results The range for correctly completed tasks was 16 to 64 percent, for incorrectly completed tasks 18 to 38 percent and for incomplete tasks 9 to 47 percent. The authors identified 286 usability problems. The main types were three unsuccessful attempts, negative affect and task incorrectly completed. They also identified six problematic interface and interaction designs that led to usability problems. Conclusion The four dental CPR systems studied have significant usability problems for novice users, resulting in a steep learning curve and potentially reduced system adoption. Clinical Implications The significant number of data entry errors raises concerns about the quality of documentation in clinical practice. PMID:19047669

  20. Perceived usability and use of custom-made footwear in diabetic patients at high risk for foot ulceration.

    PubMed

    Arts, Mark L J; de Haart, Mirjam; Bus, Sicco A; Bakker, Jan P J; Hacking, Hub G A; Nollet, Frans

    2014-04-01

    To assess the perceived usability and use of custom- made footwear in diabetic patients who are at high-risk for foot ulceration, and to elucidate the determinants of usability and use. Survey. A total of 153 patients with diabetes, peripheral neuropathy, prior plantar foot ulceration and newly prescribed custom-made footwear, recruited from 10 Dutch multidisciplinary foot clinics. The Questionnaire of Usability Evaluation was used to assess the patients' perception of weight, appearance, comfort, durability, donning/doffing, stability, benefit and overall appreciation of their prescription footwear (all expressed as visual analogue scores). Data on priorities for usability and footwear use (in h/day) were obtained from patient reports. Multivariate logistic regression analysis was used to assess determinants of usability and use. Median (interquartile range) score for overall appreciation was 8.3 (7.1-9.1). Scores ranged from 6.5 (4.5-8.6) for weight to 9.6 (6.3-9.9) for donning/doffing. Footwear comfort was listed most often (33.3%) as the highest priority. Footwear use was <60% of daytime (where daytime was defined as 16 h out of bed) in 58% of patients. The only significant determinant of footwear use was the perceived benefit of the footwear (p = 0.045). Perceived usability of footwear was mostly positive, although individual scores and priorities varied considerably. Footwear use was low to moderate and dependent only on the perceived benefit of the footwear. Therefore, practitioners should focus on enhancing the patient's ap-preciation of the therapeutic benefit of custom-made footwear.

  1. Factors associated with participation frequency and satisfaction among people applying for a housing adaptation grant.

    PubMed

    Thordardottir, Björg; Ekstam, Lisa; Chiatti, Carlos; Fänge, Agneta Malmgren

    2016-09-01

    People applying for a housing adaptation (HA) grant are at great risk of participation restrictions due to declining capacity and environmental barriers. To investigate the association of person-, environment-, and activity-related factors with participation frequency and satisfaction among people applying for a housing adaptation grant. Baseline cross-sectional data were collected during home visits (n = 128). The association between person-, environment-, and activity-related factors and participation frequency and satisfaction was analysed using logistic regressions. The main result is that frequency of participation outside the home is strongly associated with dependence in activities of daily living (ADL) and cognitive impairments, while satisfaction with participation outside the home is strongly associated with self-reported health. Moreover, aspects of usability in the home were associated with frequency of participation outside the home and satisfaction with participation in the home and outside the home alone. Dependence in ADL, cognitive impairments, self-rated health, and aspects of usability are important factors contributing to participation frequency and satisfaction among people applying for a housing adaptation grant, particularly outside the home. Our findings indicate that more attention should be directed towards activity-related factors to facilitate participation among HA applicants, inside and outside the home.

  2. Usability Methods for Ensuring Health Information Technology Safety: Evidence-Based Approaches. Contribution of the IMIA Working Group Health Informatics for Patient Safety.

    PubMed

    Borycki, E; Kushniruk, A; Nohr, C; Takeda, H; Kuwata, S; Carvalho, C; Bainbridge, M; Kannry, J

    2013-01-01

    Issues related to lack of system usability and potential safety hazards continue to be reported in the health information technology (HIT) literature. Usability engineering methods are increasingly used to ensure improved system usability and they are also beginning to be applied more widely for ensuring the safety of HIT applications. These methods are being used in the design and implementation of many HIT systems. In this paper we describe evidence-based approaches to applying usability engineering methods. A multi-phased approach to ensuring system usability and safety in healthcare is described. Usability inspection methods are first described including the development of evidence-based safety heuristics for HIT. Laboratory-based usability testing is then conducted under artificial conditions to test if a system has any base level usability problems that need to be corrected. Usability problems that are detected are corrected and then a new phase is initiated where the system is tested under more realistic conditions using clinical simulations. This phase may involve testing the system with simulated patients. Finally, an additional phase may be conducted, involving a naturalistic study of system use under real-world clinical conditions. The methods described have been employed in the analysis of the usability and safety of a wide range of HIT applications, including electronic health record systems, decision support systems and consumer health applications. It has been found that at least usability inspection and usability testing should be applied prior to the widespread release of HIT. However, wherever possible, additional layers of testing involving clinical simulations and a naturalistic evaluation will likely detect usability and safety issues that may not otherwise be detected prior to widespread system release. The framework presented in the paper can be applied in order to develop more usable and safer HIT, based on multiple layers of evidence.

  3. Quantum Information Science

    DTIC Science & Technology

    2012-02-01

    group velocity matched temporal compensator crystal assembly to increase the usable range of entangled photon sources, and (vi) the development and...characterization of a new multipli- entangled photon source that increased the usable number of photon pairs by a factor of six. 15. SUBJECT TERMS...compensated crystal assembly ....................................................................................... 17 3.7 Entangled photon sources

  4. Exploring the Role of Usability in the Software Process: A Study of Irish Software SMEs

    NASA Astrophysics Data System (ADS)

    O'Connor, Rory V.

    This paper explores the software processes and usability techniques used by Small and Medium Enterprises (SMEs) that develop web applications. The significance of this research is that it looks at development processes used by SMEs in order to assess to what degree usability is integrated into the process. This study seeks to gain an understanding into the level of awareness of usability within SMEs today and their commitment to usability in practice. The motivation for this research is to explore the current development processes used by SMEs in developing web applications and to understand how usability is represented in those processes. The background for this research is provided by the growth of the web application industry beyond informational web sites to more sophisticated applications delivering a broad range of functionality. This paper presents an analysis of the practices of several Irish SMEs that develop web applications through a series of case studies. With the focus on SMEs that develop web applications as Management Information Systems and not E-Commerce sites, informational sites, online communities or web portals. This study gathered data about the usability techniques practiced by these companies and their awareness of usability in the context of the software process in those SMEs. The contribution of this study is to further the understanding of the current role of usability within the software development processes of SMEs that develop web applications.

  5. Reconfigurable Wideband Circularly Polarized Stacked Square Patch Antenna for Cognitive Radios

    NASA Technical Reports Server (NTRS)

    Barbosa Kortright, Miguel A.; Waldstein, Seth W.; Simons, Rainee N.

    2017-01-01

    An almost square patch, a square patch and a stacked square patch with corner truncation for circular polarization (CP) are researched and developed at X-band for cognitive radios. Experimental results indicate, first, that the impedance bandwidth of a CP almost square patch fed from the edge by a 50 ohm line is 1.70% and second, that of a CP square patch fed from the ground plane side by a surface launch connector is 1.87%. Third, the impedance bandwidth of a CP stacked square patch fed by a surface launch connector is 2.22%. The measured center frequency for the CP square patch fed by a surface launch connector without and with an identical stacked patch is 8.45 and 8.1017 GHz, respectively. By stacking a patch, separated by a fixed air gap of 0.254 mm, the center frequency is observed to shift by as much as 348.3 MHz. The shift in center frequency, brought about by the reconfiguring of the physical layer antenna, can be exploited in a cognitive system since it expands the usable frequency spectrum for software reconfiguration in the presence of interference. In addition, varying the fixed air gap in the stacked antenna geometry by increments of 0.254 mm further expands the usable frequency spectrum.

  6. Operating manual-based usability evaluation of medical devices: an effective patient safety screening method.

    PubMed

    Turley, James P; Johnson, Todd R; Smith, Danielle Paige; Zhang, Jaijie; Brixey, Juliana J

    2006-04-01

    Use of medical devices often directly contributes to medical errors. Because it is difficult or impossible to change the design of existing devices, the best opportunity for improving medical device safety is during the purchasing process. However, most hospital personnel are not familiar with the usability evaluation methods designed to identify aspects of a user interface that do not support intuitive and safe use. A review of medical device operating manuals is proposed as a more practical method of usability evaluation. Operating manuals for five volumetric infusion pumps from three manufacturers were selected for this study (January-April 2003). Each manual's safety message content was evaluated to determine whether the message indicated a device design characteristic that violated known usability principles (heuristics) or indicated a violation of an affordance of the device. "Minimize memory load," with 65 violations, was the heuristic violated most frequently across pumps. Variations between pumps, including the frequency and severity of violations for each, were noted. Results suggest that manual review can provide a proxy for heuristic evaluation of the actual medical device. This method, intended to be a component of prepurchasing evaluation, can complement more formal usability evaluation methods and be used to select a subset of devices for more extensive and formal testing.

  7. A Re-evaluation of Discarded Deceased Donor Kidneys in the UK: Are Usable Organs Still Being Discarded?

    PubMed

    Mittal, Shruti; Adamusiak, Anna; Horsfield, Catherine; Loukopoulos, Ioannis; Karydis, Nikolaos; Kessaris, Nicos; Drage, Martin; Olsburgh, Jonathon; Watson, Christopher Je; Callaghan, Chris J

    2017-07-01

    A significant proportion of procured deceased donor kidneys are subsequently discarded. The UK Kidney Fast-Track Scheme (KFTS) was introduced in 2012, enabling kidneys at risk of discard to be simultaneously offered to participating centers. We undertook an analysis of discarded kidneys to determine if unnecessary organ discard was still occurring since the KFTS was introduced. Between April and June 2015, senior surgeons independently inspected 31 consecutive discarded kidneys from throughout the United Kingdom. All kidneys were biopsied. Organs were categorized as usable, possibly usable pending histology, or not usable for implantation. After histology reports were available, final assessments of usability were made. There were 19 donors (6 donations after brain death, 13 donations after circulatory death), with a median (range) donor age of 67 (29-83) years and Kidney Donor Profile Index of 93 (19-100). Reasons for discard were variable. Only 3 discarded kidneys had not entered the KFTS. After initial assessment postdiscard, 11 kidneys were assessed as usable, with 9 kidneys thought to be possibly usable. Consideration of histological data reduced the number of kidneys thought usable to 10 (10/31; 32%). The KFTS scheme is successfully identifying organs at high risk of discard, though potentially transplantable organs are still being discarded. Analyses of discarded organs are essential to identify barriers to organ utilization and develop strategies to reduce unnecessary discard.

  8. Web-Based Teaching and Learning Approach (WBTLA) Usability in Institutions of Higher Learning in Malaysia

    ERIC Educational Resources Information Center

    Nordin, Abu Bakar; Alias, Norlidah

    2013-01-01

    Today teachers in schools and lecturers in institutions of higher learning are endowed with a wide range of new teaching experiences through web-based teaching and learning approaches (WBTLA), which was not possible before through the traditional classroom approach. With the use of WBTLA emerged problems related to usability in technical,…

  9. Testing the Usability of Interactive Visualizations for Complex Problem-Solving: Findings Related to Improving Interfaces and Help.

    ERIC Educational Resources Information Center

    Mirel, Barbara

    2001-01-01

    Conducts a scenario-based usability test with 10 data analysts using visual querying (visually analyzing data with interactive graphics). Details a range of difficulties found in visual selection that, at times, gave rise to inaccurate selections, invalid conclusions, and misguided decisions. Argues that support for visual selection must be built…

  10. Linking Pedagogical Theory of Computer Games to their Usability

    ERIC Educational Resources Information Center

    Ang, Chee Siang; Avni, Einav; Zaphiris, Panayiotis

    2008-01-01

    This article reviews a range of literature of computer games and learning theories and attempts to establish a link between them by proposing a typology of games which we use as a new usability measure for the development of guidelines for game-based learning. First, we examine game literature in order to understand the key elements that…

  11. Multidither Adaptive Algorithms

    DTIC Science & Technology

    1976-09-01

    Influence Function Profiles of Beryllium Mirror 32 11 Three-Dimensional View of Central-Actuator Influence for RADC Beryllium Mirror 33 12 Contour Lines...installed at this writing. Some preliminary tests on the mirror have determined its excur- sion sensitivity, influence function , and frequency...The frequency response shows some unusual resonance behavior, but is usable to at least 30 kHz. The 1 5 influence function has a shape given

  12. Monolithically integrated quantum dot optical modulator with Semiconductor optical amplifier for short-range optical communications

    NASA Astrophysics Data System (ADS)

    Yamamoto, Naokatsu; Akahane, Kouichi; Umezawa, Toshimasa; Kawanishi, Tetsuya

    2015-04-01

    A monolithically integrated quantum dot (QD) optical gain modulator (OGM) with a QD semiconductor optical amplifier (SOA) was successfully developed. Broadband QD optical gain material was used to achieve Gbps-order high-speed optical data transmission, and an optical gain change as high as approximately 6-7 dB was obtained with a low OGM voltage of 2.0 V. Loss of optical power due to insertion of the device was also effectively compensated for by the SOA section. Furthermore, it was confirmed that the QD-OGM/SOA device helped achieve 6.0-Gbps error-free optical data transmission over a 2.0-km-long photonic crystal fiber. We also successfully demonstrated generation of Gbps-order, high-speed, and error-free optical signals in the >5.5-THz broadband optical frequency bandwidth larger than the C-band. These results suggest that the developed monolithically integrated QD-OGM/SOA device will be an advantageous and compact means of increasing the usable optical frequency channels for short-reach communications.

  13. Analysis and Design of a Long Range PTFE Substrate UHF RFID Tag for Cargo Container Identification

    NASA Astrophysics Data System (ADS)

    Petrariu, Adrian-Ioan; Popa, Valentin

    2016-01-01

    In this paper, a high-performances microstrip antenna for UHF (ultra high frequency) RFID (radio frequency identification) tag is designed, prototyped and tested. The antenna consists of two main components: a 1.52 mm RT/duroid 5880 laminate substrate on which the antenna is designed and a 10 mm polytetrafluoroethylene (PTFE) dielectric material placed as a separator between the antenna and the reference ground plane for the microstrip antenna. With this structure, the RFID tag can reach a maximum reading distance of 19 m, although the antenna has a compact size of 80 mm × 50 mm. The long reading distance is obtained by attaching to the antenna an RFID chip that can provide a reading sensitivity of -20.5 dBm. The high bandwidth from 677 MHz to 947 MHz measured at -10 dB, makes the tag being usable worldwide especially for cargo container identification, the main purpose of this research.

  14. Applications of Optical Neuroimaging in Usability Research

    PubMed Central

    Hill, Audrey P.; Bohil, Corey J.

    2016-01-01

    FEATURE AT A GLANCE In this article we review recent and potential applications of optical neuroimaging to human factors and usability research. We focus specifically on functional near-infrared spectroscopy (fNIRS) because of its cost-effectiveness and ease of implementation. Researchers have used fNIRS to assess a range of psychological phenomena relevant to human factors, such as cognitive workload, attention, motor activity, and more. It offers the opportunity to measure hemodynamic correlates of mental activity during task completion in human factors and usability studies. We also consider some limitations and future research directions. PMID:28286404

  15. Interdisciplinary development of manual and automated product usability assessments for older adults with dementia: lessons learned.

    PubMed

    Boger, Jennifer; Taati, Babak; Mihailidis, Alex

    2016-10-01

    The changes in cognitive abilities that accompany dementia can make it difficult to use everyday products that are required to complete activities of daily living. Products that are inherently more usable for people with dementia could facilitate independent activity completion, thus reducing the need for caregiver assistance. The objectives of this research were to: (1) gain an understanding of how water tap design impacted tap usability and (2) create an automated computerized tool that could assess tap usability. 27 older adults, who ranged from cognitively intact to advanced dementia, completed 1309 trials on five tap designs. Data were manually analyzed to investigate tap usability as well as used to develop an automated usability analysis tool. Researchers collaborated to modify existing techniques and to create novel ones to accomplish both goals. This paper presents lessons learned through the course of this research, which could be applicable in the development of other usability studies, automated vision-based assessments and the development of assistive technologies for cognitively impaired older adults. Collaborative interdisciplinary teamwork, which included older adult with dementia participants, was key to enabling innovative advances that achieved the projects' research goals. Implications for Rehabilitation Products that are implicitly familiar and usable by older adults could foster independent activity completion, potentially reducing reliance on a caregiver. The computer-based automated tool can significantly reduce the time and effort required to perform product usability analysis, making this type of analysis more feasible. Interdisciplinary collaboration can result in a more holistic understanding of assistive technology research challenges and enable innovative solutions.

  16. Fine structure of the low-frequency spectra of heart rate and blood pressure

    PubMed Central

    Kuusela, Tom A; Kaila, Timo J; Kähönen, Mika

    2003-01-01

    Background The aim of this study was to explore the principal frequency components of the heart rate and blood pressure variability in the low frequency (LF) and very low frequency (VLF) band. The spectral composition of the R–R interval (RRI) and systolic arterial blood pressure (SAP) in the frequency range below 0.15 Hz were carefully analyzed using three different spectral methods: Fast Fourier transform (FFT), Wigner-Ville distribution (WVD), and autoregression (AR). All spectral methods were used to create time–frequency plots to uncover the principal spectral components that are least dependent on time. The accurate frequencies of these components were calculated from the pole decomposition of the AR spectral density after determining the optimal model order – the most crucial factor when using this method – with the help of FFT and WVD methods. Results Spectral analysis of the RRI and SAP of 12 healthy subjects revealed that there are always at least three spectral components below 0.15 Hz. The three principal frequency components are 0.026 ± 0.003 (mean ± SD) Hz, 0.076 ± 0.012 Hz, and 0.117 ± 0.016 Hz. These principal components vary only slightly over time. FFT-based coherence and phase-function analysis suggests that the second and third components are related to the baroreflex control of blood pressure, since the phase difference between SAP and RRI was negative and almost constant, whereas the origin of the first component is different since no clear SAP–RRI phase relationship was found. Conclusion The above data indicate that spontaneous fluctuations in heart rate and blood pressure within the standard low-frequency range of 0.04–0.15 Hz typically occur at two frequency components rather than only at one as widely believed, and these components are not harmonically related. This new observation in humans can help explain divergent results in the literature concerning spontaneous low-frequency oscillations. It also raises methodological and computational questions regarding the usability and validity of the low-frequency spectral band when estimating sympathetic activity and baroreflex gain. PMID:14552660

  17. Fine structure of the low-frequency spectra of heart rate and blood pressure.

    PubMed

    Kuusela, Tom A; Kaila, Timo J; Kähönen, Mika

    2003-10-13

    The aim of this study was to explore the principal frequency components of the heart rate and blood pressure variability in the low frequency (LF) and very low frequency (VLF) band. The spectral composition of the R-R interval (RRI) and systolic arterial blood pressure (SAP) in the frequency range below 0.15 Hz were carefully analyzed using three different spectral methods: Fast Fourier transform (FFT), Wigner-Ville distribution (WVD), and autoregression (AR). All spectral methods were used to create time-frequency plots to uncover the principal spectral components that are least dependent on time. The accurate frequencies of these components were calculated from the pole decomposition of the AR spectral density after determining the optimal model order--the most crucial factor when using this method--with the help of FFT and WVD methods. Spectral analysis of the RRI and SAP of 12 healthy subjects revealed that there are always at least three spectral components below 0.15 Hz. The three principal frequency components are 0.026 +/- 0.003 (mean +/- SD) Hz, 0.076 +/- 0.012 Hz, and 0.117 +/- 0.016 Hz. These principal components vary only slightly over time. FFT-based coherence and phase-function analysis suggests that the second and third components are related to the baroreflex control of blood pressure, since the phase difference between SAP and RRI was negative and almost constant, whereas the origin of the first component is different since no clear SAP-RRI phase relationship was found. The above data indicate that spontaneous fluctuations in heart rate and blood pressure within the standard low-frequency range of 0.04-0.15 Hz typically occur at two frequency components rather than only at one as widely believed, and these components are not harmonically related. This new observation in humans can help explain divergent results in the literature concerning spontaneous low-frequency oscillations. It also raises methodological and computational questions regarding the usability and validity of the low-frequency spectral band when estimating sympathetic activity and baroreflex gain.

  18. Prostate Cancer on the Web-Expedient Tool for Patients' Decision-Making?

    PubMed

    Borgmann, Hendrik; Wölm, Jan-Henning; Vallo, Stefan; Mager, Rene; Huber, Johannes; Breyer, Johannes; Salem, Johannes; Loeb, Stacy; Haferkamp, Axel; Tsaur, Igor

    2017-03-01

    Many patients diagnosed with cancer search for health information on the Web. We aimed to assess the quality and reliability of online health information on prostate cancer. Google, Yahoo, and Bing were searched for the term "prostate cancer." After selecting the most frequented websites, quality was measured by DISCERN score, JAMA benchmark criteria, and presence of HONcode certification. Popularity was assessed by Alexa tool, while accessibility, usability, and reliability were investigated by LIDA tool. Readability was analyzed by Flesch-Kincaid Reading Grade Level and Automated Readability Index. All 13 selected websites were rated as being of high quality according to the DISCERN instrument (76.5 ± 2.6 out of 80 points). JAMA benchmark criteria were fulfilled by 87 % of websites, whereas only 37 % were certified by the HONcode. Median Alexa Traffic Rank was 2718 ranging from 7 to 679,038. Websites received 2.3 ± 0.5 daily pageviews per visitor and users spent an average of 2 min 58 s ± 39 sec on the website. Accessibility (92 ± 5 %) and usability (92 ± 3 %) scores were high and reliability (88 ± 8 %) moderate according to the LIDA tool. Flesch-Kincaid Grade Level was 7.9 ± 2.2, and Automated Readability Index was 7.5 ± 2.4, rating the websites as fairly difficult to read. In conclusion, quality, accessibility, and usability of websites on prostate cancer provided a high rating in the current analysis. These findings are encouraging in view of the growing frequency of patients' access of health information online.

  19. Systematic Heuristic Evaluation of Computerized Consultation Order Templates: Clinicians' and Human Factors Engineers' Perspectives.

    PubMed

    Savoy, April; Patel, Himalaya; Flanagan, Mindy E; Weiner, Michael; Russ, Alissa L

    2017-08-01

    We assessed the usability of consultation order templates and identified problems to prioritize in design efforts for improving referral communication. With a sample of 26 consultation order templates, three evaluators performed a usability heuristic evaluation. The evaluation used 14 domain-independent heuristics and the following three supplemental references: 1 new domain-specific heuristic, 6 usability goals, and coded clinicians' statements regarding ease of use for 10 sampled templates. Evaluators found 201 violations, a mean of 7.7 violations per template. Minor violations outnumbered major violations almost twofold, 115 (57%) to 62 (31%). Approximately 68% of violations were linked to 5 heuristics: aesthetic and minimalist design (17%), error prevention (16%), consistency and standards (14%), recognition rather than recall (11%), and meet referrers' information needs (10%). Severe violations were attributed mostly to meet referrers' information needs and recognition rather than recall. Recorded violations yielded potential negative consequences for efficiency, effectiveness, safety, learnability, and utility. Evaluators and clinicians demonstrated 80% agreement in usability assessment. Based on frequency and severity of usability heuristic violations, the consultation order templates reviewed may impede clinical efficiency and risk patient safety. Results support the following design considerations: communicate consultants' requirements, facilitate information seeking, and support communication. While the most frequent heuristic violations involved interaction design and presentation, the most severe violations lacked information desired by referring clinicians. Violations related to templates' inability to support referring clinicians' information needs had the greatest potential negative impact on efficiency and safety usability goals. Heuristics should be prioritized in future design efforts.

  20. The Effects of a Mobile Phone Application on Quality of Life in Patients With Type 1 Diabetes Mellitus: A Randomized Controlled Trial.

    PubMed

    Drion, Iefke; Pameijer, Loes R; van Dijk, Peter R; Groenier, Klaas H; Kleefstra, Nanne; Bilo, Henk J G

    2015-05-11

    The combination of an increasing prevalence of diabetes mellitus and more people having access to smartphones creates opportunities for patient care. This study aims to investigate whether the use of the Diabetes Under Control (DBEES) mobile phone application, a digital diabetes diary, results in a change in quality of life for patients with type 1 diabetes mellitus (T1DM) compared with the standard paper diary. In this randomized controlled open-label trial, 63 patients with T1DM having access to a smartphone were assigned to the intervention group using the DBEES application (n = 31) or the control group using the standard paper diary (n = 32). Primary outcome was the change in quality of life, as measured by the RAND-36 questionnaire, between both groups. Secondary outcomes included diabetes-related distress (PAID), HbA1c, frequency of self-monitoring blood glucose, and the usability of the diabetes application (SUS). Patients had a median age (IQR) of 33 (21) years, diabetes duration of 17 (16) years, and an HbA1c of 62 ± 16 mmol/mol. No significant differences in the QOL, using the RAND-36, within and between both groups were observed after 3 months. Glycemic control, diabetes-related emotional distress, and frequency of self-monitoring of blood glucose remained within and between groups. Users reviewed the usability of DBEES with a 72 ± 20, on a range of 0-100. The use of the DBEES application in the management of patients with T1DM for 3 months yields no alterations in quality of life compared to the standard paper diary. © 2015 Diabetes Technology Society.

  1. Numerical Simulations of the XR-5 Hall Thruster for Life Assessment at Different Operating Conditions

    NASA Technical Reports Server (NTRS)

    Lopez Ortega, Alejandro; Jorns, Benjamin A.; Mikellides, Ioannis G.; Hofer, Richard R.

    2015-01-01

    NASA's Jet Propulsion Laboratory has been investigating the applicability of Aerojet Rocketdyne's XR-5 thruster, a 4.5 kW class Hall thruster, for deep-space missions. Major considerations for qualifying the XR-5 for deep-space missions are demonstration of a wide throttling envelope and a usable life capability in excess of 10,000 h. Numerical simulations with the 2-D axisymmetric code Hall2De are employed to inform the qualification process by assessing erosion rates at the thruster surfaces in a wide range of throttling conditions without the need for conducting costly endurance testing. In previous work at JPL by Jorns et al., the anomalous collision frequency distribution for 11 different throttling conditions of the XR-5 spanning 0.3-4.5 kW were identified based on probe measurements of the electron temperature in the near plume region. In this paper, we provide estimates for the erosion rates at the channel walls and pole covers for the same 11 conditions. Uncertainties in the plasma measurements and in the anomalous collision frequency distribution are addressed by determining upper and lower bounds of the erosion rates. Results suggest that erosion of the walls only occurs in the last 5% of the acceleration channel and the rate of such erosion decreases as the geometry of the thruster changes in time due to magnetic shielding. A quasi-zero-erosion state is eventually achieved in all the examined throttling conditions. Examination of the results for pole surface erosion and estimated cathode life indicates that the XR-5 propellant throughput capability will exceed 700 kg, which provides 50% margin over the usable throughput capability of 466 kg as already demonstrated in wear testing.

  2. Assessment of the quality of patient-oriented information over internet on testicular cancer.

    PubMed

    Prasanth, Anton S; Jayarajah, Umesh; Mohanappirian, Ranganathan; Seneviratne, Sanjeewa A

    2018-05-02

    This study aimed to assess the quality and readability of patient education information available on the internet on testicular cancer. Internet searches were performed using the keywords 'testicular cancer', 'testicular tumour', 'testicular tumor', 'testicular malignancy', 'germ cell tumour' and 'germ cell tumor' using Google, Yahoo! And Bing search engines with default settings. The first 50 web links appeared in each search engine were evaluated for their readability by using the validated Flesch Reading Ease Score (FRES) while accessibility, usability and reliability were assessed using the LIDA tool. The quality was assessed using DISCERN instrument. Non-parametric tests were used for statistical analysis. Overall, 900 websites were assessed and 62 websites were included in the analysis. Twenty two (22) websites (35.5%) were certified by Health on the Net Foundation code of conduct (HON code). The majority (n = 57, 91.9%) were non-governmental websites. The median FRES score was 51.6 (range: 28.1-74.1), the overall median LIDA score was 115 (range: 81-147); accessibility 55 (range: 46-61), reliability 22 (range: 8-45) and usability 38.5 (range: 21-50), while the median DISCERN score was 43.5 (range: 16-69). The DISCERN score was significantly associated with the overall LIDA score and usability and reliability components of the LIDA score (p < 0.001). However, no significant associations were observed between readability and accessibility. A significant correlation was noted between usability and reliability components of the LIDA score (Spearman's rho: 0.789, p < 0.001). In this study, the readability, reliability and quality scores of most websites were found to be suboptimal and hence, there is potential for improvement. As the internet is expanding rapidly as a readily available source of information to the public, it is essential to implement steps to ensure that highest quality information is provided without any commercial motivation or bias.

  3. Usability evaluation and adaptation of the e-health Personal Patient Profile-Prostate decision aid for Spanish-speaking Latino men.

    PubMed

    Berry, Donna L; Halpenny, Barbara; Bosco, Jaclyn L F; Bruyere, John; Sanda, Martin G

    2015-07-24

    The Personal Patient Profile-Prostate (P3P), a web-based decision aid, was demonstrated to reduce decisional conflict in English-speaking men with localized prostate cancer early after initial diagnosis. The purpose of this study was to explore and enhance usability and cultural appropriateness of a Spanish P3P by Latino men with a diagnosis of prostate cancer. P3P was translated to Spanish and back-translated by three native Spanish-speaking translators working independently. Spanish-speaking Latino men with a diagnosis of localized prostate cancer, who had made treatment decisions in the past 24 months, were recruited from two urban clinical care sites. Individual cognitive interviews were conducted by two bilingual research assistants as each participant used the Spanish P3P. Notes of user behavior, feedback, and answers to direct questions about comprehension, usability and perceived usefulness were analyzed and categorized. Seven participants with a range of education levels identified 25 unique usability issues in navigation, content comprehension and completeness, sociocultural appropriateness, and methodology. Revisions were prioritized to refine the usability and cultural and linguistic appropriateness of the decision aid. Usability issues were discovered that are potential barriers to effective decision support. Successful use of decision aids requires adaptation and testing beyond translation. Our findings led to revisions further refining the usability and linguistic and cultural appropriateness of Spanish P3P.

  4. Phased array antenna matching: Simulation and optimization of a planar phased array of circular waveguide elements

    NASA Technical Reports Server (NTRS)

    Dudgeon, J. E.

    1972-01-01

    A computerized simulation of a planar phased array of circular waveguide elements is reported using mutual coupling and wide angle impedance matching in phased arrays. Special emphasis is given to circular polarization. The aforementioned computer program has as variable inputs: frequency, polarization, grid geometry, element size, dielectric waveguide fill, dielectric plugs in the waveguide for impedance matching, and dielectric sheets covering the array surface for the purpose of wide angle impedance matching. Parameter combinations are found which produce reflection peaks interior to grating lobes, while dielectric cover sheets are successfully employed to extend the usable scan range of a phased array. The most exciting results came from the application of computer aided optimization techniques to the design of this type of array.

  5. A Piezoelectric Shear Stress Sensor

    NASA Technical Reports Server (NTRS)

    Kim, Taeyang; Saini, Aditya; Kim, Jinwook; Gopalarathnam, Ashok; Zhu, Yong; Palmieri, Frank L.; Wohl, Christopher J.; Jiang, Xiaoning

    2016-01-01

    In this paper, a piezoelectric sensor with a floating element was developed for shear stress measurement. The piezoelectric sensor was designed to detect the pure shear stress suppressing effects of normal stress generated from the vortex lift-up by applying opposite poling vectors to the: piezoelectric elements. The sensor was first calibrated in the lab by applying shear forces and it showed high sensitivity to shear stress (=91.3 +/- 2.1 pC/Pa) due to the high piezoelectric coefficients of PMN-33%PT (d31=-1330 pC/N). The sensor also showed almost no sensitivity to normal stress (less than 1.2 pC/Pa) because of the electromechanical symmetry of the device. The usable frequency range of the sensor is 0-800 Hz. Keywords: Piezoelectric sensor, shear stress, floating element, electromechanical symmetry

  6. User Interface Problems of a Nationwide Inpatient Information System: A Heuristic Evaluation.

    PubMed

    Atashi, Alireza; Khajouei, Reza; Azizi, Amirabbas; Dadashi, Ali

    2016-01-01

    While studies have shown that usability evaluation could uncover many design problems of health information systems, the usability of health information systems in developing countries using their native language is poorly studied. The objective of this study was to evaluate the usability of a nationwide inpatient information system used in many academic hospitals in Iran. Three trained usability evaluators independently evaluated the system using Nielsen's 10 usability heuristics. The evaluators combined identified problems in a single list and independently rated the severity of the problems. We statistically compared the number and severity of problems identified by HIS experienced and non-experienced evaluators. A total of 158 usability problems were identified. After removing duplications 99 unique problems were left. The highest mismatch with usability principles was related to "Consistency and standards" heuristic (25%) and the lowest related to "Flexibility and efficiency of use" (4%). The average severity of problems ranged from 2.4 (Major problem) to 3.3 (Catastrophe problem). The experienced evaluator with HIS identified significantly more problems and gave higher severities to problems (p<0.02). Heuristic Evaluation identified a high number of usability problems in a widely used inpatient information system in many academic hospitals. These problems, if remain unsolved, may waste users' and patients' time, increase errors and finally threaten patient's safety. Many of them can be fixed with simple redesign solutions such as using clear labels and better layouts. This study suggests conducting further studies to confirm the findings concerning effect of evaluator experience on the results of Heuristic Evaluation.

  7. User Interface Problems of a Nationwide Inpatient Information System: A Heuristic Evaluation

    PubMed Central

    Atashi, Alireza; Azizi, Amirabbas; Dadashi, Ali

    2016-01-01

    Summary Introduction While studies have shown that usability evaluation could uncover many design problems of health information systems, the usability of health information systems in developing countries using their native language is poorly studied. The objective of this study was to evaluate the usability of a nationwide inpatient information system used in many academic hospitals in Iran. Material and Methods Three trained usability evaluators independently evaluated the system using Nielsen’s 10 usability heuristics. The evaluators combined identified problems in a single list and independently rated the severity of the problems. We statistically compared the number and severity of problems identified by HIS experienced and non-experienced evaluators. Results A total of 158 usability problems were identified. After removing duplications 99 unique problems were left. The highest mismatch with usability principles was related to “Consistency and standards” heuristic (25%) and the lowest related to “Flexibility and efficiency of use” (4%). The average severity of problems ranged from 2.4 (Major problem) to 3.3 (Catastrophe problem). The experienced evaluator with HIS identified significantly more problems and gave higher severities to problems (p<0.02). Discussion Heuristic Evaluation identified a high number of usability problems in a widely used inpatient information system in many academic hospitals. These problems, if remain unsolved, may waste users’ and patients’ time, increase errors and finally threaten patient’s safety. Many of them can be fixed with simple redesign solutions such as using clear labels and better layouts. This study suggests conducting further studies to confirm the findings concerning effect of evaluator experience on the results of Heuristic Evaluation. PMID:27081409

  8. Electronic health record usability: analysis of the user-centered design processes of eleven electronic health record vendors.

    PubMed

    Ratwani, Raj M; Fairbanks, Rollin J; Hettinger, A Zachary; Benda, Natalie C

    2015-11-01

    The usability of electronic health records (EHRs) continues to be a point of dissatisfaction for providers, despite certification requirements from the Office of the National Coordinator that require EHR vendors to employ a user-centered design (UCD) process. To better understand factors that contribute to poor usability, a research team visited 11 different EHR vendors in order to analyze their UCD processes and discover the specific challenges that vendors faced as they sought to integrate UCD with their EHR development. Our analysis demonstrates a diverse range of vendors' UCD practices that fall into 3 categories: well-developed UCD, basic UCD, and misconceptions of UCD. Specific challenges to practicing UCD include conducting contextually rich studies of clinical workflow, recruiting participants for usability studies, and having support from leadership within the vendor organization. The results of the study provide novel insights for how to improve usability practices of EHR vendors. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. AC power generation from microbial fuel cells

    NASA Astrophysics Data System (ADS)

    Lobo, Fernanda Leite; Wang, Heming; Forrestal, Casey; Ren, Zhiyong Jason

    2015-11-01

    Microbial fuel cells (MFCs) directly convert biodegradable substrates to electricity and carry good potential for energy-positive wastewater treatment. However, the low and direct current (DC) output from MFC is not usable for general electronics except small sensors, yet commercial DC-AC converters or inverters used in solar systems cannot be directly applied to MFCs. This study presents a new DC-AC converter system for MFCs that can generate alternating voltage in any desired frequency. Results show that AC power can be easily achieved in three different frequencies tested (1, 10, 60 Hz), and no energy storage layer such as capacitors was needed. The DC-AC converter efficiency was higher than 95% when powered by either individual MFCs or simple MFC stacks. Total harmonic distortion (THD) was used to investigate the quality of the energy, and it showed that the energy could be directly usable for linear electronic loads. This study shows that through electrical conversion MFCs can be potentially used in household electronics for decentralized off-grid communities.

  10. Satellite Power System (SPS) microwave subsystem impacts and benefits

    NASA Technical Reports Server (NTRS)

    Dickinson, R. M.

    1977-01-01

    The impacts and benefits to society of the microwave subsystem resulting from the developing, construction and operating of a space solar power to earth, electric power delivery system are presented and discussed. The primary benefit (usable energy) is conveyed mainly in the fundamental frequency portion of the RF radiation beam that is intercepted and converted to electric power output. The small fraction of the microwave and other electromagnetic energy that does not end up in the electric utility grid, yields most of the subsystem impacts. The impacts range from harmonics and noise radiated by the transmitting antenna, through potential interference with ionospheric communications and navigation caused by the power beam heating the ionosphere, to the potential large land area requirements for the rectennas and low level microwave radiation around the rectennas. Additional benefits range from a very low level of waste heat liberated and lack of atmospheric emissions including noise while operating to having no residual ionizing radiation from the rectenna when it is deactivated.

  11. Usability in telemedicine systems-A literature survey.

    PubMed

    Klaassen, B; van Beijnum, B J F; Hermens, H J

    2016-09-01

    The rapid development of sensors and communication technologies enable the growth of new innovative services in healthcare, such as Telemedicine. An essential ingredient in the development of a telemedicine system and its final acceptance by end users are usability studies. The principles of usability engineering, evaluations and telemedicine are well established, and it may contribute to the adoption and eventually deployment of such systems and services. An in-depth usability analysis, including performance and attitude measures, requires knowledge about available usability techniques, and is depending on the amount of resources. Therefore it is worth investigating how usability methods are applied in developing telemedicine systems. Our hypothesis is: with increasing research and development of telemedicine systems, we expect that various usability methods are more equally employed for different end-user groups and applications. A literature survey was conducted to find telemedicine systems that have been evaluated for usability or ease of use. The elements of the PICO framework were used as a basis for the selection criteria in the literature search. The search was not limited by year. Two independent reviewers screened all search results first by title, and then by abstract for inclusion. Articles were included up to May 2015. In total, 127 publications were included in this survey. The number of publications on telemedicine systems significantly increased after 2008. Older adults and end-users with cardiovascular conditions were among largest target end-user groups. Remote monitoring systems were found the most, in 90 publications. Questionnaires are the most common means for evaluating telemedicine systems, and were found in 88 publications. Questionnaires are used frequently in studies focusing on cardiovascular diseases, Parkinson's disease and older adult conditions. Interviews are found the most in publications related to stroke. In total 71% of the publications were trial-orientated and the remaining process orientated. An increase in telemedicine research, development and applications is found worldwide, with the majority of publications conducted in America. Monitoring patients in their homes can lead to better healthcare at lower costs which implies an increased demand of new healthcare strategies like telemedicine. We expected that with the increase in telemedicine research and development, a greater range of usability methods would also be employed in the included publications. This is not the case. Researchers employed questionnaires as a preferred usability method for each type of telemedicine system and most end-users. However, in process-orientated studies a greater range of usability evaluations were applied, with fewer differences found in the amount of publications for each evaluation method. Questionnaires enable researchers to evaluate a system quickly on end users, as it requires less expertise on the evaluation method compared to the other methods. They are easily distributed and are customizable. The use of questionnaires is therefore an evaluation method of choice for a variety of telemedicine systems and end-users. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. Identification of task demands and usability issues in police use of mobile computing terminals.

    PubMed

    Zahabi, Maryam; Kaber, David

    2018-01-01

    Crash reports from various states in the U.S. have shown high numbers of emergency vehicle crashes, especially in law enforcement situations. This study identified the perceived importance and frequency of police mobile computing terminal (MCT) tasks, quantified the demands of different tasks using a cognitive performance modeling methodology, identified usability violations of current MCT interface designs, and formulated design recommendations for an enhanced interface. Results revealed that "access call notes", "plate number check" and "find location on map" are the most important and frequently performed tasks for officers. "Reading plate information" was also found to be the most visually and cognitively demanding task-method. Usability principles of "using simple and natural dialog" and "minimizing user memory load" were violated by the current MCT interface design. The enhanced design showed potential for reducing cognitive demands and task completion time. Findings should be further validated using a driving simulation study. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Radio frequency (RF) microwave components and subsystems using loaded ridge waveguide

    DOEpatents

    Kang, Yoon W.

    2013-08-20

    A waveguide having a non-conductive material with a high permeability (.mu., .mu..sub.r for relative permeability) and/or a high permittivity (.di-elect cons., .di-elect cons..sub.r for relative permittivity) positioned within a housing. When compared to a hollow waveguide, the waveguide of this invention, reduces waveguide dimensions by .varies..mu. ##EQU00001## The waveguide of this invention further includes ridges which further reduce the size and increases the usable frequency bandwidth.

  14. Extraction of Pn seismic signals from air-gun shots recorded by the Cascadia Amphibious seismic experiment

    NASA Astrophysics Data System (ADS)

    Rathnayaka, S.; Gao, H.

    2017-12-01

    The goal of this study is to extract Pn (head wave) seismic waveforms recorded by both offshore and onshore (broadband and short period) seismic stations and evaluate the data quality. Two offshore active-source seismic experiments, MGL 1211 and MGL 1212, were conducted from 13th June to 24th July 2012, during the first year deployment of the Cascadia Initiative Amphibious Array. In total, we choose 110 ocean bottom seismometers and 209 inland stations that are located along the entire Cascadia subduction zone. We first remove the instrument response, and then explore the potential frequency ranges and the diurnal effect. We make the common receiver gathering for each seismic station and filter the seismic waveforms at multiple frequency bands, ranging from 3-5 Hz, 5-10 Hz, 10-20 Hz, to 20-40 Hz, respectively. To quantitatively evaluate the data quality, we calculate the signal-to-noise ratio (SNR) of the waveforms for usable stations that record clear Pn arrivals at multiple frequency bands. Our results show that most offshore stations located at deep water (>1.5 km) record clear air-gun shot signals at frequencies higher than 3 Hz and up to 550 km away from the source. For most stations located on the shallow continental shelf, the seismic recordings appear much noisier at all the frequencies compared to stations at deep water. Three general trends are observed for the SNR distribution; First, the SNR ratio increases from lower to higher frequency bands; Second, the ratio decreases with the increasing source-to-receiver distance; And third, the ratio increases from shallow to deep water. We also observe a rough negative relationship of the signal-to-noise ratio with the thickness of the marine sediment. Only 5 inland stations record clear air-gun shot arrivals up to 200 km away from the source. More detailed data quality analysis with more results will also be present.

  15. LOX/hydrocarbon rocket engine analytical design methodology development and validation. Volume 2: Appendices

    NASA Technical Reports Server (NTRS)

    Niiya, Karen E.; Walker, Richard E.; Pieper, Jerry L.; Nguyen, Thong V.

    1993-01-01

    This final report includes a discussion of the work accomplished during the period from Dec. 1988 through Nov. 1991. The objective of the program was to assemble existing performance and combustion stability models into a usable design methodology capable of designing and analyzing high-performance and stable LOX/hydrocarbon booster engines. The methodology was then used to design a validation engine. The capabilities and validity of the methodology were demonstrated using this engine in an extensive hot fire test program. The engine used LOX/RP-1 propellants and was tested over a range of mixture ratios, chamber pressures, and acoustic damping device configurations. This volume contains time domain and frequency domain stability plots which indicate the pressure perturbation amplitudes and frequencies from approximately 30 tests of a 50K thrust rocket engine using LOX/RP-1 propellants over a range of chamber pressures from 240 to 1750 psia with mixture ratios of from 1.2 to 7.5. The data is from test configurations which used both bitune and monotune acoustic cavities and from tests with no acoustic cavities. The engine had a length of 14 inches and a contraction ratio of 2.0 using a 7.68 inch diameter injector. The data was taken from both stable and unstable tests. All combustion instabilities were spontaneous in the first tangential mode. Although stability bombs were used and generated overpressures of approximately 20 percent, no tests were driven unstable by the bombs. The stability instrumentation included six high-frequency Kistler transducers in the combustion chamber, a high-frequency Kistler transducer in each propellant manifold, and tri-axial accelerometers. Performance data is presented, both characteristic velocity efficiencies and energy release efficiencies, for those tests of sufficient duration to record steady state values.

  16. 'Televaluation' of clinical information systems: an integrative approach to assessing Web-based systems.

    PubMed

    Kushniruk, A W; Patel, C; Patel, V L; Cimino, J J

    2001-04-01

    The World Wide Web provides an unprecedented opportunity for widespread access to health-care applications by both patients and providers. The development of new methods for assessing the effectiveness and usability of these systems is becoming a critical issue. This paper describes the distance evaluation (i.e. 'televaluation') of emerging Web-based information technologies. In health informatics evaluation, there is a need for application of new ideas and methods from the fields of cognitive science and usability engineering. A framework is presented for conducting evaluations of health-care information technologies that integrates a number of methods, ranging from deployment of on-line questionnaires (and Web-based forms) to remote video-based usability testing of user interactions with clinical information systems. Examples illustrating application of these techniques are presented for the assessment of a patient clinical information system (PatCIS), as well as an evaluation of use of Web-based clinical guidelines. Issues in designing, prototyping and iteratively refining evaluation components are discussed, along with description of a 'virtual' usability laboratory.

  17. Usability Test of an Interactive Dietary Recording

    ERIC Educational Resources Information Center

    Chung, Louisa Ming Yan; Chung, Joanne Wai Yee; Wong, Thomas Kwok Shing

    2009-01-01

    Dietary intake methods are used to collect one's diet habit which is essential in nutrition assessment. Food diary, food frequency questionnaire (FFQ) and 24-hour recalls are the most common dietary intake methods. However, they are not welcomed by most clients. Digital handheld devices are now readily available, and the cost of digital…

  18. Controller for a wave energy converter

    DOEpatents

    Wilson, David G.; Bull, Diana L.; Robinett, III, Rush D.

    2015-09-22

    A wave energy converter (WEC) is described, the WEC including a power take off (PTO) that converts relative motion of bodies of the WEC into electrical energy. A controller controls operation of the PTO, causing the PTO to act as a motor to widen a wave frequency spectrum that is usable to generate electrical energy.

  19. Applications of palynology and kerogen analysis to California Paleogene stratigraphy and paleoenvironment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lucas-Clark, J.

    1988-03-01

    Paleogene strata of California commonly yield usable preserved organic material. Fossil pollen, spores, and dinoflagellates of chronostratigraphic significance are recovered from Paleogene rocks that contain no other usable fossil material. Palynofacies analysis, which combines data from fossil species with data from kerogen analysis, is used to interpret paleo-environmental aspects such as paleobathymetry, probable upwelling, turbulence, and rates of sedimentation. Examples of applications come from Paleogene submarine canyon deposits, the northern California Franciscan coastal belt, and southern California Transverse Ranges.

  20. Multi-method laboratory user evaluation of an actionable clinical performance information system: Implications for usability and patient safety.

    PubMed

    Brown, Benjamin; Balatsoukas, Panos; Williams, Richard; Sperrin, Matthew; Buchan, Iain

    2018-01-01

    Electronic audit and feedback (e-A&F) systems are used worldwide for care quality improvement. They measure health professionals' performance against clinical guidelines, and some systems suggest improvement actions. However, little is known about optimal interface designs for e-A&F, in particular how to present suggested actions for improvement. We developed a novel theory-informed system for primary care (the Performance Improvement plaN GeneratoR; PINGR) that covers the four principal interface components: clinical performance summaries; patient lists; detailed patient-level information; and suggested actions. As far as we are aware, this is the first report of an e-A&F system with all four interface components. (1) Use a combination of quantitative and qualitative methods to evaluate the usability of PINGR with target end-users; (2) refine existing design recommendations for e-A&F systems; (3) determine the implications of these recommendations for patient safety. We recruited seven primary care physicians to perform seven tasks with PINGR, during which we measured on-screen behaviour and eye movements. Participants subsequently completed usability questionnaires, and were interviewed in-depth. Data were integrated to: gain a more complete understanding of usability issues; enhance and explain each other's findings; and triangulate results to increase validity. Participants committed a median of 10 errors (range 8-21) when using PINGR's interface, and completed a median of five out of seven tasks (range 4-7). Errors violated six usability heuristics: clear response options; perceptual grouping and data relationships; representational formats; unambiguous description; visually distinct screens for confusable items; and workflow integration. Eye movement analysis revealed the integration of components largely supported effective user workflow, although the modular design of clinical performance summaries unnecessarily increased cognitive load. Interviews and questionnaires revealed PINGR is user-friendly, and that improved information prioritisation could further promote useful user action. Comparing our results with the wider usability literature we refine a previously published set of interface design recommendations for e-A&F. The implications for patient safety are significant regarding: user engagement; actionability; and information prioritisation. Our results also support adopting multi-method approaches in usability studies to maximise issue discovery and the credibility of findings. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  1. A Breastfeed-Promoting Mobile App Intervention: Usability and Usefulness Study

    PubMed Central

    2018-01-01

    Background Breastfeeding is proven to have lasting health benefits for both mothers and infants; however, 6-month exclusive breastfeeding rate remains below 20% in Thailand. Although the number of research literature and commercial apps for breastfeeding women is significantly growing, they are country-specific and restricted to English-speaking users. There exists a major knowledge gap on how mobile health apps could support breastfeeding in Thailand. To address these gaps, MoomMae has been developed with the intention to support Thai women in breastfeeding outside of their homes and in keeping their feeding records. Objective The aim of this study was to evaluate the usability and usefulness of MoomMae, a mobile phone app designed to support breastfeeding women. Methods Our study was reviewed and approved by Thailand’s National Science and Technology Development Agency (NSTDA) ethics committee. A total of 21 breastfeeding women with at least one Android phone or tablet were recruited via convenience and snowball sampling. The study process for each participant was as follows: the participant was requested to attend a preuse interview and given the app to use for 4 weeks. Following this period, a postuse interview was conducted to examine the usability and usefulness of the app. Both sessions were held individually and audiorecorded for qualitative analysis. Results The mean scores of usability and usefulness from the postuse survey were 4.33 (SD 0.87; range 1-5) and 4.60 (SD 0.74; range 2-5). Our qualitative analysis revealed a total of 137 feedbacks: 71 related to usability and 66 associated with usefulness. A further sentimental analysis showed that comments on usability were generally negative (59 negative, 11 positive, and 1 neutral), and comments on usefulness were relatively positive (56 positive, 9 negative, and 1 neutral). We discovered 26 unique design issues and proposed recommendations for future improvement. Conclusions Our usability and usefulness assessment of MoomMae demonstrated that MoomMae has a great potential to be a useful self-management tool for breastfeeding mothers in Thailand. The qualitative analysis suggested that the app is supportive of breastfeeding on demand, but the flow and inputs of the app should be redesigned to be more intuitive. For future implementations, the most desirable feature is a pump-reminding notification system. PMID:29374000

  2. A Breastfeed-Promoting Mobile App Intervention: Usability and Usefulness Study.

    PubMed

    Wang, Chih-Jau; Chaovalit, Pimwadee; Pongnumkul, Suporn

    2018-01-26

    Breastfeeding is proven to have lasting health benefits for both mothers and infants; however, 6-month exclusive breastfeeding rate remains below 20% in Thailand. Although the number of research literature and commercial apps for breastfeeding women is significantly growing, they are country-specific and restricted to English-speaking users. There exists a major knowledge gap on how mobile health apps could support breastfeeding in Thailand. To address these gaps, MoomMae has been developed with the intention to support Thai women in breastfeeding outside of their homes and in keeping their feeding records. The aim of this study was to evaluate the usability and usefulness of MoomMae, a mobile phone app designed to support breastfeeding women. Our study was reviewed and approved by Thailand's National Science and Technology Development Agency (NSTDA) ethics committee. A total of 21 breastfeeding women with at least one Android phone or tablet were recruited via convenience and snowball sampling. The study process for each participant was as follows: the participant was requested to attend a preuse interview and given the app to use for 4 weeks. Following this period, a postuse interview was conducted to examine the usability and usefulness of the app. Both sessions were held individually and audiorecorded for qualitative analysis. The mean scores of usability and usefulness from the postuse survey were 4.33 (SD 0.87; range 1-5) and 4.60 (SD 0.74; range 2-5). Our qualitative analysis revealed a total of 137 feedbacks: 71 related to usability and 66 associated with usefulness. A further sentimental analysis showed that comments on usability were generally negative (59 negative, 11 positive, and 1 neutral), and comments on usefulness were relatively positive (56 positive, 9 negative, and 1 neutral). We discovered 26 unique design issues and proposed recommendations for future improvement. Our usability and usefulness assessment of MoomMae demonstrated that MoomMae has a great potential to be a useful self-management tool for breastfeeding mothers in Thailand. The qualitative analysis suggested that the app is supportive of breastfeeding on demand, but the flow and inputs of the app should be redesigned to be more intuitive. For future implementations, the most desirable feature is a pump-reminding notification system. ©Chih-Jau Wang, Pimwadee Chaovalit, Suporn Pongnumkul. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 26.01.2018.

  3. High-current, high-frequency capacitors

    NASA Technical Reports Server (NTRS)

    Renz, D. D.

    1983-01-01

    The NASA Lewis high-current, high-frequency capacitor development program was conducted under a contract with Maxwell Laboratories, Inc., San Diego, California. The program was started to develop power components for space power systems. One of the components lacking was a high-power, high-frequency capacitor. Some of the technology developed in this program may be directly usable in an all-electric airplane. The materials used in the capacitor included the following: the film is polypropylene, the impregnant is monoisopropyl biphenyl, the conductive epoxy is Emerson and Cuming Stycast 2850 KT, the foil is aluminum, the case is stainless steel (304), and the electrode is a modified copper-ceramic.

  4. Acceptance and usability of a home-based monitoring tool of health indicators in children of people with dementia: a Proof of Principle (POP) study.

    PubMed

    Boessen, April Bcg; Vermeulen, Joan; de Witte, Luc P

    2017-01-01

    Large-scale cohort studies are needed to confirm the relation between dementia and its possible risk factors. The inclusion of people with dementia in research is a challenge, however, children of people with dementia are at risk and are highly motivated to participate in dementia research. For technologies to support home-based data collection during large-scale studies, participants should be able and willing to use technology for a longer period of time. This study investigated acceptance and usability of iVitality, a research platform for home-based monitoring of dementia health indicators, in 151 children of people with dementia and investigated which frequency of measurements is acceptable for them. Participants were randomized to fortnightly or monthly measurements. At baseline and after 3 months, participants completed an online questionnaire regarding the acceptance (Technology Acceptance Model; 38 items) and usability (Post-Study System Usability Questionnaire; 24 items) of iVitality. Items were rated from 1 (I totally disagree) to 7 (I totally agree). Participants were also invited to take part in an online focus group (OFG) after 3 months of follow-up. Descriptive statistics and both two-sample/independent and paired t -tests were used to analyze the online questionnaires and a directed content analysis was used to analyze the OFGs. Children of people with dementia accept iVitality after long-term use and evaluate iVitality as a user-friendly, useful, and trusted technology, despite some suggestions for improvement. Overall, mean scores on acceptance and usability were higher than 5 (I somewhat agree), although the acceptance subscales "social influence" and "time" were rated somewhat lower. No significant differences in acceptance and usability were found between both protocol groups. Over time, "affect" significantly increased among participants measuring blood pressure fortnightly. iVitality has the potential to be used in large-scale studies for home-based monitoring of health indicators related to the development of dementia.

  5. Cognitive engineering of film library transition from film medium to digital environment in a Texas teaching hospital.

    PubMed

    Koperwhats, Martha A; Chang, Wei-Chih; Xiao, Jianguo

    2002-01-01

    Digital imaging technology promises efficient, economical, and fast service for patient care, but the challenges are great in the transition from film to a filmless (digital) environment. This change has a significant impact on the film library's personnel (film librarians) who play a leading roles in storage, classification, and retrieval of images. The objectives of this project were to study film library errors and the usability of a physical computerized system that could not be changed, while developing an intervention to reduce errors and test the usability of the intervention. Cognitive and human factors analysis were used to evaluate human-computer interaction. A workflow analysis was performed to understand the film and digital imaging processes. User and task analyses were applied to account for all behaviors involved in interaction with the system. A heuristic evaluation was used to probe the usability issues in the picture archiving and communication systems (PACS) modules. Simplified paper-based instructions were designed to familiarize the film librarians with the digital system. A usability survey evaluated the effectiveness of the instruction. The user and task analyses indicated that different users faced challenges based on their computer literacy, education, roles, and frequency of use of diagnostic imaging. The workflow analysis showed that the approaches to using the digital library differ among the various departments. The heuristic evaluation of the PACS modules showed the human-computer interface to have usability issues that prevented easy operation. Simplified instructions were designed for operation of the modules. Usability surveys conducted before and after revision of the instructions showed that performance improved. Cognitive and human factor analysis can help film librarians and other users adapt to the filmless system. Use of cognitive science tools will aid in successful transition of the film library from a film environment to a digital environment.

  6. Usability Assessment of the Missouri Cancer Registry's Published Interactive Mapping Reports: Round One.

    PubMed

    Ben Ramadan, Awatef Ahmed; Jackson-Thompson, Jeannette; Schmaltz, Chester Lee

    2017-08-04

     Many users of spatial data have difficulty interpreting information in health-related spatial reports. The Missouri Cancer Registry and Research Center (MCR-ARC) has produced interactive reports for several years. These reports have never been tested for usability.  The aims of this study were to: (1) conduct a multi-approach usability testing study to understand ease of use (user friendliness) and user satisfaction; and (2) evaluate the usability of MCR-ARC's published InstantAtlas reports.   An institutional review board (IRB) approved mixed methodology usability testing study using a convenience sample of health professionals. A recruiting email was sent to faculty in the Master of Public Health program and to faculty and staff in the Department of Health Management and Informatics at the University of Missouri-Columbia. The study included 7 participants. The test included a pretest questionnaire, a multi-task usability test, and the System Usability Scale (SUS). Also, the researchers collected participants' comments about the tested maps immediately after every trial. Software was used to record the computer screen during the trial and the participants' spoken comments. Several performance and usability metrics were measured to evaluate the usability of MCR-ARC's published mapping reports. Of the 10 assigned tasks, 6 reached a 100% completion success rate, and this outcome was relative to the complexity of the tasks. The simple tasks were handled more efficiently than the complicated tasks. The SUS score ranged between 20-100 points, with an average of 62.7 points and a median of 50.5 points. The tested maps' effectiveness outcomes were better than the efficiency and satisfaction outcomes. There was a statistically significant relationship between the subjects' performance on the study test and the users' previous experience with geographic information system (GIS) tools (P=.03). There were no statistically significant relationships between users' performance and satisfaction and their education level, work type, or previous experience in health care (P>.05). There were strong positive correlations between the three measured usability elements. The tested maps should undergo an extensive refining and updating to overcome all the discovered usability issues and meet the perspectives and needs of the tested maps' potential users. The study results might convey the perspectives of academic health professionals toward GIS health data. We need to conduct a second-round usability study with public health practitioners and cancer professionals who use GIS tools on a routine basis. Usability testing should be conducted before and after releasing MCR-ARC's maps in the future. ©Awatef Ahmed Ben Ramadan, Jeannette Jackson-Thompson, Chester Lee Schmaltz. Originally published in JMIR Human Factors (http://humanfactors.jmir.org), 04.08.2017.

  7. Usability Assessment of the Missouri Cancer Registry’s Published Interactive Mapping Reports: Round One

    PubMed Central

    Jackson-Thompson, Jeannette; Schmaltz, Chester Lee

    2017-01-01

    Background  Many users of spatial data have difficulty interpreting information in health-related spatial reports. The Missouri Cancer Registry and Research Center (MCR-ARC) has produced interactive reports for several years. These reports have never been tested for usability. Objective  The aims of this study were to: (1) conduct a multi-approach usability testing study to understand ease of use (user friendliness) and user satisfaction; and (2) evaluate the usability of MCR-ARC’s published InstantAtlas reports. Methods   An institutional review board (IRB) approved mixed methodology usability testing study using a convenience sample of health professionals. A recruiting email was sent to faculty in the Master of Public Health program and to faculty and staff in the Department of Health Management and Informatics at the University of Missouri-Columbia. The study included 7 participants. The test included a pretest questionnaire, a multi-task usability test, and the System Usability Scale (SUS). Also, the researchers collected participants’ comments about the tested maps immediately after every trial. Software was used to record the computer screen during the trial and the participants’ spoken comments. Several performance and usability metrics were measured to evaluate the usability of MCR-ARC’s published mapping reports. Results Of the 10 assigned tasks, 6 reached a 100% completion success rate, and this outcome was relative to the complexity of the tasks. The simple tasks were handled more efficiently than the complicated tasks. The SUS score ranged between 20-100 points, with an average of 62.7 points and a median of 50.5 points. The tested maps’ effectiveness outcomes were better than the efficiency and satisfaction outcomes. There was a statistically significant relationship between the subjects’ performance on the study test and the users’ previous experience with geographic information system (GIS) tools (P=.03). There were no statistically significant relationships between users’ performance and satisfaction and their education level, work type, or previous experience in health care (P>.05). There were strong positive correlations between the three measured usability elements. Conclusions The tested maps should undergo an extensive refining and updating to overcome all the discovered usability issues and meet the perspectives and needs of the tested maps’ potential users. The study results might convey the perspectives of academic health professionals toward GIS health data. We need to conduct a second-round usability study with public health practitioners and cancer professionals who use GIS tools on a routine basis. Usability testing should be conducted before and after releasing MCR-ARC’s maps in the future. PMID:28778842

  8. Proposing Electronic Health Record Usability Requirements Based on Enriched ISO 9241 Metric Usability Model

    PubMed Central

    Farzandipour, Mehrdad; Riazi, Hossein; Jabali, Monireh Sadeqi

    2018-01-01

    Introduction: System usability assessment is among the important aspects in assessing the quality of clinical information technology, especially when the end users of the system are concerned. This study aims at providing a comprehensive list of system usability. Methods: This research is a descriptive cross-sectional one conducted using Delphi technique in three phases in 2013. After experts’ ideas were concluded, the final version of the questionnaire including 163 items in three phases was presented to 40 users of information systems in hospitals. The grading ranged from 0-4. Data analysis was conducted using SPSS software. Those requirements with a mean point of three or higher were finally confirmed. Results: The list of system usability requirements for electronic health record was designed and confirmed in nine areas including suitability for the task (24 items), self-descriptiveness (22 items), controllability (19 questions), conformity with user expectations (25 items), error tolerance (21 items), suitability for individualization (7 items), suitability for learning (19 items), visual clarity (18 items) and auditory presentation (8 items). Conclusion: A relatively comprehensive model including useful requirements for using EHR was presented which can increase functionality, effectiveness and users’ satisfaction. Thus, it is suggested that the present model be adopted by system designers and healthcare system institutions to assess those systems. PMID:29719310

  9. Usability study of youtube websites for Malaysian teenagers

    NASA Astrophysics Data System (ADS)

    Razak, Mohd Nur Faiz Abd; Hussain, Azham; Hamdi, Mohd Maizan Fishol

    2017-10-01

    Nowadays, YouTube is the 3rd most visited website in the world. It was created for users to search, watch and share video. Statistics show that YouTube run in more than 88 countries and support 76 different languages which covered almost 95% of Internet population globally. Therefore, a usability study is for specific type of users such as based on gender, range of age and country is considered a must for this kind of top website. In this study, we focus on YouTube website usability for Malaysian teenagers that are currently schooling in boarding school with limited access of Internet. It was done in a controlled lab environment with proper devices and software as MacBook, LCD Monitor, and WhatPulse heat map tracker. The evaluation was made based on usability metrics: ease of use, usefulness and satisfaction of users with combination of recording videos, mouse and keyboard heat map and questionnaires. Findings show that most of the respondents just use YouTube for video watching only while ignoring other features in the same time. There are difficulties in using it at the first moment but could catch up in short time. It shows how usable YouTube website especially in the learnability and memorability aspects.

  10. Monolithically integrated quantum dot optical gain modulator with semiconductor optical amplifier for 10-Gb/s photonic transmission

    NASA Astrophysics Data System (ADS)

    Yamamoto, Naokatsu; Akahane, Kouichi; Umezawa, Toshimasa; Kawanishi, Tetsuya

    2015-03-01

    Short-range interconnection and/or data center networks require high capacity and a large number of channels in order to support numerous connections. Solutions employed to meet these requirements involve the use of alternative wavebands to increase the usable optical frequency range. We recently proposed the use of the T- and O-bands (Thousand band: 1000-1260 nm, Original band: 1260-1360 nm) as alternative wavebands because large optical frequency resources (>60 THz) can be easily employed. In addition, a simple and compact Gb/s-order high-speed optical modulator is a critical photonic device for short-range communications. Therefore, to develop an optical modulator that acts as a highfunctional photonic device, we focused on the use of self-assembled quantum dots (QDs) as a three-dimensional (3D) confined structure because QD structures are highly suitable for realizing broadband optical gain media in the T+O bands. In this study, we use the high-quality broadband QD optical gain to develop a monolithically integrated QD optical gain modulator (QD-OGM) device that has a semiconductor optical amplifier (QD-SOA) for Gb/s-order highspeed optical data generation in the 1.3-μm waveband. The insertion loss of the device can be compensated through the SOA, and we obtained an optical gain change of up to ~7 dB in the OGM section. Further, we successfully demonstrate a 10-Gb/s clear eye opening using the QD-OGM/SOA device with a clock-data recovery sequence at the receiver end. These results suggest that the monolithic QD-EOM/SOA is suitable for increasing the number of wavelength channels for smart short-range communications.

  11. Usability of a CKD educational website targeted to patients and their family members.

    PubMed

    Diamantidis, Clarissa J; Zuckerman, Marni; Fink, Wanda; Hu, Peter; Yang, Shiming; Fink, Jeffrey C

    2012-10-01

    Web-based technology is critical to the future of healthcare. As part of the Safe Kidney Care cohort study evaluating patient safety in CKD, this study determined how effectively a representative sample of patients with CKD or family members could interpret and use the Safe Kidney Care website (www.safekidneycare.org), an informational website on safety in CKD. Between November of 2011 and January of 2012, persons with CKD or their family members underwent formal usability testing administered by a single interviewer with a second recording observer. Each participant was independently provided a list of 21 tasks to complete, with each task rated as either easily completed/noncritical error or critical error (user cannot complete the task without significant interviewer intervention). Twelve participants completed formal usability testing. Median completion time for all tasks was 17.5 minutes (range=10-44 minutes). In total, 10 participants had greater than or equal to one critical error. There were 55 critical errors in 252 tasks (22%), with the highest proportion of critical errors occurring when participants were asked to find information on treatments that may damage kidneys, find the website on the internet, increase font size, and scroll to the bottom of the webpage. Participants were generally satisfied with the content and usability of the website. Web-based educational materials for patients with CKD should target a wide range of computer literacy levels and anticipate variability in competency in use of the computer and internet.

  12. Comparing usability testing outcomes and functions of six electronic nursing record systems.

    PubMed

    Cho, Insook; Kim, Eunman; Choi, Woan Heui; Staggers, Nancy

    2016-04-01

    This study examined the usability of six differing electronic nursing record (ENR) systems on the efficiency, proficiency and available functions for documenting nursing care and subsequently compared the results to nurses' perceived satisfaction from a previous study. The six hospitals had different ENR systems, all with narrative nursing notes in use for more than three years. Stratified by type of nursing unit, 54 staff nurses were digitally recorded during on-site usability testing by employing validated patient care scenarios and think-aloud protocols. The time to complete specific tasks was also measured. Qualitative performance data were converted into scores on efficiency (relevancy), proficiency (accuracy), and a competency index using scoring schemes described by McGuire and Babbott. Six nurse managers and the researchers completed assessments of available ENR functions and examined computerized nursing process components including the linkages among them. For the usability test, participants' mean efficiency score was 94.2% (95% CI, 91.4-96.9%). The mean proficiency was 60.6% (95% CI, 54.3-66.8%), and the mean competency index was 59.5% (95% CI, 52.9-66.0). Efficiency scores were significantly different across ENRs as was the time to complete tasks, ranging from 226.3 to 457.2s (χ(2)=12.3, P=0.031; χ(2)=11.2, P=0.048). No significant differences were seen for proficiency scores. The coverage of the various ENRs' nursing process ranged from 67% to 100%, but only two systems had complete integration of nursing components. Two systems with high efficiency and proficiency scores had much lower usability test scores and perceived user satisfaction along with more complex navigation patterns. In terms of system usability and functions, different levels of sophistication of and interaction performance with ENR systems exist in practice. This suggests that ENRs may have variable impacts on clinical outcomes and care quality. Future studies are needed to explore ENR impact on nursing care quality, efficiency, and safety. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. Overview of an Indoor Sonic Boom Simulator at NASA Langley Research Center

    NASA Technical Reports Server (NTRS)

    Klos, Jacob

    2012-01-01

    A facility has been constructed at NASA Langley Research Center to simulate the soundscape inside residential houses that are exposed to environmental noise from aircraft. This controllable indoor listening environment, the Interior Effects Room, enables systematic study of parameters that affect psychoacoustic response. The single-room facility, built using typical residential construction methods and materials, is surrounded on adjacent sides by two arrays of loudspeakers in close proximity to the exterior walls. The arrays, containing 52 subwoofers and 52 mid-range speakers, have a usable bandwidth of 3 Hz to 5 kHz and sufficient output to allow study of sonic boom noise. In addition to these exterior arrays, satellite speakers placed inside the room are used to augment the transmitted sound with rattle and other audible contact ]induced noise that can result from low frequency excitation of a residential house. The layout of the facility, operational characteristics, acoustic characteristics and equalization approaches are summarized.

  14. Mobile Phone App Aimed at Improving Iron Intake and Bioavailability in Premenopausal Women: A Qualitative Evaluation

    PubMed Central

    Riddell, Lynn; Lim, Karen; Byrne, Linda K; Nowson, Caryl; Rigo, Manuela; Szymlek-Gay, Ewa A; Booth, Alison O

    2015-01-01

    Background Low iron intake can lead to iron deficiency, which can result in impaired health and iron-deficiency anemia. A mobile phone app, combining successful dietary strategies to increase bioavailable iron with strategies for behavior change, such as goal setting, monitoring, feedback, and resources for knowledge acquisition, was developed with the aim to increase bioavailable iron intake in premenopausal women. Objective To evaluate the content, usability, and acceptability of a mobile phone app designed to improve intake of bioavailable dietary iron. Methods Women aged 18-50 years with an Android mobile phone were invited to participate. Over a 2-week period women were asked to interact with the app. Following this period, semistructured focus groups with participants were conducted. Focus groups were audio recorded and analyzed via an inductive open-coding method using the qualitative analysis software NVivo 10. Themes were identified and frequency of code occurrence was calculated. Results Four focus groups (n=26) were conducted (age range 19-36 years, mean 24.7, SD 5.2). Two themes about the app’s functionality were identified (frequency of occurrence in brackets): interface and design (134) and usability (86). Four themes about the app’s components were identified: goal tracker (121), facts (78), photo diary (40), and games (46). A number of suggestions to improve the interface and design of the app were provided and will inform the ongoing development of the app. Conclusions This research indicates that participants are interested in iron and their health and are willing to use an app utilizing behavior change strategies to increase intake of bioavailable iron. The inclusion of information about the link between diet and health, monitoring and tracking of the achievement of dietary goals, and weekly reviews of goals were also seen as valuable components of the app and should be considered in mobile health apps aimed at adult women. PMID:26416479

  15. Mobile applications for diabetics: a systematic review and expert-based usability evaluation considering the special requirements of diabetes patients age 50 years or older.

    PubMed

    Arnhold, Madlen; Quade, Mandy; Kirch, Wilhelm

    2014-04-09

    A multitude of mhealth (mobile health) apps have been developed in recent years to support effective self-management of patients with diabetes mellitus type 1 or 2. We carried out a systematic review of all currently available diabetes apps for the operating systems iOS and Android. We considered the number of newly released diabetes apps, range of functions, target user groups, languages, acquisition costs, user ratings, available interfaces, and the connection between acquisition costs and user ratings. Additionally, we examined whether the available applications serve the special needs of diabetes patients aged 50 or older by performing an expert-based usability evaluation. We identified relevant keywords, comparative categories, and their specifications. Subsequently, we performed the app review based on the information given in the Google Play Store, the Apple App Store, and the apps themselves. In addition, we carried out an expert-based usability evaluation based on a representative 10% sample of diabetes apps. In total, we analyzed 656 apps finding that 355 (54.1%) offered just one function and 348 (53.0%) provided a documentation function. The dominating app language was English (85.4%, 560/656), patients represented the main user group (96.0%, 630/656), and the analysis of the costs revealed a trend toward free apps (53.7%, 352/656). The median price of paid apps was €1.90. The average user rating was 3.6 stars (maximum 5). Our analyses indicated no clear differences in the user rating between free and paid apps. Only 30 (4.6%) of the 656 available diabetes apps offered an interface to a measurement device. We evaluated 66 apps within the usability evaluation. On average, apps were rated best regarding the criterion "comprehensibility" (4.0 out of 5.0), while showing a lack of "fault tolerance" (2.8 out of 5.0). Of the 66 apps, 48 (72.7%) offered the ability to read the screen content aloud. The number of functions was significantly negative correlated with usability. The presence of documentation and analysis functions reduced the usability score significantly by 0.36 and 0.21 points. A vast number of diabetes apps already exist, but the majority offer similar functionalities and combine only one to two functions in one app. Patients and physicians alike should be involved in the app development process to a greater extent. We expect that the data transmission of health parameters to physicians will gain more importance in future applications. The usability of diabetes apps for patients aged 50 or older was moderate to good. But this result applied mainly to apps offering a small range of functions. Multifunctional apps performed considerably worse in terms of usability. Moreover, the presence of a documentation or analysis function resulted in significantly lower usability scores. The operability of accessibility features for diabetes apps was quite limited, except for the feature "screen reader".

  16. Evaluating the usability of a virtual reality-based Android application in managing the pain experience of wheelchair users.

    PubMed

    Spyridonis, Fotios; Gronli, Tor-Morten; Hansen, Jarle; Ghinea, Gheorghita

    2012-01-01

    Pain constitutes an important medical concern that can have severe implications to a wheelchair user's quality of life. Results from studies indicate that pain is a common problem in this group of individuals, having a reported frequency of always (12%) and everyday (33%). This incidence signifies the need for more applicable and effective pain management clinical tools. As a result, in this paper we present an Android application (PainDroid) that has been enhanced with Virtual Reality (VR) technology for the purpose of improving the management of pain. Our evaluation with a group of wheelchair users revealed that PainDroid demonstrated high usability among this population, and is foreseen that it can make an important contribution in research on the assessment and management of pain.

  17. Real-Time Processing Library for Open-Source Hardware Biomedical Sensors

    PubMed Central

    Castro-García, Juan A.; Lebrato-Vázquez, Clara

    2018-01-01

    Applications involving data acquisition from sensors need samples at a preset frequency rate, the filtering out of noise and/or analysis of certain frequency components. We propose a novel software architecture based on open-software hardware platforms which allows programmers to create data streams from input channels and easily implement filters and frequency analysis objects. The performances of the different classes given in the size of memory allocated and execution time (number of clock cycles) were analyzed in the low-cost platform Arduino Genuino. In addition, 11 people took part in an experiment in which they had to implement several exercises and complete a usability test. Sampling rates under 250 Hz (typical for many biomedical applications) makes it feasible to implement filters, sliding windows and Fourier analysis, operating in real time. Participants rated software usability at 70.2 out of 100 and the ease of use when implementing several signal processing applications was rated at just over 4.4 out of 5. Participants showed their intention of using this software because it was percieved as useful and very easy to use. The performances of the library showed that it may be appropriate for implementing small biomedical real-time applications or for human movement monitoring, even in a simple open-source hardware device like Arduino Genuino. The general perception about this library is that it is easy to use and intuitive. PMID:29596394

  18. Real-Time Processing Library for Open-Source Hardware Biomedical Sensors.

    PubMed

    Molina-Cantero, Alberto J; Castro-García, Juan A; Lebrato-Vázquez, Clara; Gómez-González, Isabel M; Merino-Monge, Manuel

    2018-03-29

    Applications involving data acquisition from sensors need samples at a preset frequency rate, the filtering out of noise and/or analysis of certain frequency components. We propose a novel software architecture based on open-software hardware platforms which allows programmers to create data streams from input channels and easily implement filters and frequency analysis objects. The performances of the different classes given in the size of memory allocated and execution time (number of clock cycles) were analyzed in the low-cost platform Arduino Genuino. In addition, 11 people took part in an experiment in which they had to implement several exercises and complete a usability test. Sampling rates under 250 Hz (typical for many biomedical applications) makes it feasible to implement filters, sliding windows and Fourier analysis, operating in real time. Participants rated software usability at 70.2 out of 100 and the ease of use when implementing several signal processing applications was rated at just over 4.4 out of 5. Participants showed their intention of using this software because it was percieved as useful and very easy to use. The performances of the library showed that it may be appropriate for implementing small biomedical real-time applications or for human movement monitoring, even in a simple open-source hardware device like Arduino Genuino. The general perception about this library is that it is easy to use and intuitive.

  19. AMOLED (active matrix OLED) functionality and usable lifetime at temperature

    NASA Astrophysics Data System (ADS)

    Fellowes, David A.; Wood, Michael V.; Prache, Olivier; Jones, Susan

    2005-05-01

    Active Matrix Organic Light Emitting Diode (AMOLED) displays are known to exhibit high levels of performance, and these levels of performance have continually been improved over time with new materials and electronics design. eMagin Corporation developed a manually adjustable temperature compensation circuit with brightness control to allow for excellent performance over a wide temperature range. Night Vision and Electronic Sensors Directorate (US Army) tested the performance and survivability of a number of AMOLED displays in a temperature chamber over a range from -55°C to +85°C. Although device performance of AMOLEDs has always been its strong suit, the issue of usable display lifetimes for military applications continues to be an area of discussion and research. eMagin has made improvements in OLED materials and worked towards the development of a better understanding of usable lifetime for operation in a military system. NVESD ran luminance degradation tests of AMOLED panels at 50°C and at ambient to characterize the lifetime of AMOLED devices. The result is a better understanding of the applicability of AMOLEDs in military systems: where good fits are made, and where further development is needed.

  20. Cost comparison of re-usable and single-use fibrescopes in a large English teaching hospital.

    PubMed

    McCahon, R A; Whynes, D K

    2015-06-01

    A number of studies in the U.S.A. and mainland Europe have described the costs of fibreoptic tracheal intubation. However, no such data from the UK appear available. We performed a cost assessment of fibreoptic intubation, using re-usable (various devices from Olympus, Acutronic and Karl Storz) and single-use (Ambu aScope) fibrescopes, at the Queens Medical Centre, Nottingham, U.K., between 1 January 2009 and 31 March 2014. The total annual cost of fibreoptic intubation with re-usable fibrescopes was £46,385. Based on 141 fibreoptic intubations per year, this equated to £329 per use, an average dominated by repair/maintenance costs (43%) and capital depreciation costs (42%). In comparison, the total annual cost of using single-use fibrescopes for the same work would have been around £200 per use. The analysis enabled us to develop a generic model, wherein we were able to describe the relationship between total cost of use vs number of uses for a fibrescope. An 'isopleth' was identified for this relationship: a line that joined all the points where the cost of re-usable vs single-use fibrescopes was equal. It appears cheaper to use single-use fibrescopes at up to 200 fibreoptic intubations per year (a range commensurate with normal practice) even when the repair rate for re-usable fibrescopes is low. Any centre, knowing its fibrescope use and repair rate, can plot its data similarly to help ascertain which of the re-usable or single-use fibrescope represents better value. © 2015 The Association of Anaesthetists of Great Britain and Ireland.

  1. Review of free software tools for image analysis of fluorescence cell micrographs.

    PubMed

    Wiesmann, V; Franz, D; Held, C; Münzenmayer, C; Palmisano, R; Wittenberg, T

    2015-01-01

    An increasing number of free software tools have been made available for the evaluation of fluorescence cell micrographs. The main users are biologists and related life scientists with no or little knowledge of image processing. In this review, we give an overview of available tools and guidelines about which tools the users should use to segment fluorescence micrographs. We selected 15 free tools and divided them into stand-alone, Matlab-based, ImageJ-based, free demo versions of commercial tools and data sharing tools. The review consists of two parts: First, we developed a criteria catalogue and rated the tools regarding structural requirements, functionality (flexibility, segmentation and image processing filters) and usability (documentation, data management, usability and visualization). Second, we performed an image processing case study with four representative fluorescence micrograph segmentation tasks with figure-ground and cell separation. The tools display a wide range of functionality and usability. In the image processing case study, we were able to perform figure-ground separation in all micrographs using mainly thresholding. Cell separation was not possible with most of the tools, because cell separation methods are provided only by a subset of the tools and are difficult to parametrize and to use. Most important is that the usability matches the functionality of a tool. To be usable, specialized tools with less functionality need to fulfill less usability criteria, whereas multipurpose tools need a well-structured menu and intuitive graphical user interface. © 2014 Fraunhofer-Institute for Integrated Circuits IIS Journal of Microscopy © 2014 Royal Microscopical Society.

  2. Evaluation of the usability of a serious game aiming to teach facial expressions to schizophrenic patients.

    PubMed

    Isleyen, Filiz; Gulkesen, K Hakan; Cinemre, Buket; Samur, M Kemal; Zayim, Nese; Sen Kaya, Semiha

    2014-01-01

    In some psychological disorders such as autism and schizophrenia, loss of facial expression recognition skill may complicate patient's daily life. Information technology may help to develop facial expression recognition skill by educational software and games. We designed and developed an interactive web-based educational program with which we performed a usability study before investigating its effectiveness on the schizophrenia patients' ability of emotion perception. The purpose of this study is to describe the usability evaluation for a web-based game set that has been designed to teach facial expressions to schizophrenic patients. The usability study was done at two steps; first, we applied heuristic evaluation and the violations were rated in a scale from most to least severe and the major problems were solved. In the second step, think-aloud method was used and the web site was assessed by five schizophrenic patients. Eight experts participated in the heuristic evaluation, in which a total of 60 violations were identified with a mean severity of 2.77 (range: 0-4). All of the major problems (severity over 2.5) were listed and the usability problems were solved by the development team. After solving the problems, five users with a diagnosis of schizophrenia used the web site with the same scenario. They reported to have experienced minor, but different problems. In conclusion, we suggest that a combination of heuristic evaluation and think-aloud method may be an effective and efficient way for usability evaluations for the serious games that have been designed for special patient groups.

  3. Usability and acceptability of technology for community-dwelling older adults with mild cognitive impairment and dementia: a systematic literature review

    PubMed Central

    Holthe, Torhild; Halvorsrud, Liv; Karterud, Dag; Hoel, Kari-Anne; Lund, Anne

    2018-01-01

    Background The objective of this review was to obtain an overview of the technologies that have been explored with older adults with mild cognitive impairment and dementia (MCI/D), current knowledge on the usability and acceptability of such technologies, and how people with MCI/D and their family carers (FCs) were involved in these studies. Materials and methods Primary studies published between 2007 and 2017 that explored the use of technologies for community-dwelling people with MCI/D were identified through five databases: MEDLINE, PsycINFO, Embase, AMED, and CINAHL. Twenty-nine out of 359 papers met the criteria for eligibility. We used the Mixed Methods Appraisal Tool for quality assessment. Results A wide range of technologies was presented in the 29 studies, sorted into four domains: 1) safe walking indoors and outdoors; 2) safe living; 3) independent living; and 4) entertainment and social communication. The current state of knowledge regarding usability and acceptability reveals that even if researchers are aware of these concepts and intend to measure usability and acceptability, they seem difficult to assess. Terms such as “user friendliness” and “acceptance” were used frequently. User participation in the 29 studies was high. Persons with MCI/D, FCs, and staff/other older adults were involved in focus groups, workshops, and interviews as part of the preimplementation process. Conclusion Research regarding technologies to support people with MCI/D seems optimistic, and a wide range of technologies has been evaluated in homes with people with MCI/D and their FCs. A major finding was the importance of including people with MCI/D and their FCs in research, in order to learn about required design features to enhance usability and acceptability. Surprisingly, very few studies reported on the consequences of technology use with regard to quality of life, occupational performance, or human dignity. PMID:29765211

  4. Usability and acceptability of technology for community-dwelling older adults with mild cognitive impairment and dementia: a systematic literature review.

    PubMed

    Holthe, Torhild; Halvorsrud, Liv; Karterud, Dag; Hoel, Kari-Anne; Lund, Anne

    2018-01-01

    The objective of this review was to obtain an overview of the technologies that have been explored with older adults with mild cognitive impairment and dementia (MCI/D), current knowledge on the usability and acceptability of such technologies, and how people with MCI/D and their family carers (FCs) were involved in these studies. Primary studies published between 2007 and 2017 that explored the use of technologies for community-dwelling people with MCI/D were identified through five databases: MEDLINE, PsycINFO, Embase, AMED, and CINAHL. Twenty-nine out of 359 papers met the criteria for eligibility. We used the Mixed Methods Appraisal Tool for quality assessment. A wide range of technologies was presented in the 29 studies, sorted into four domains: 1) safe walking indoors and outdoors; 2) safe living; 3) independent living; and 4) entertainment and social communication. The current state of knowledge regarding usability and acceptability reveals that even if researchers are aware of these concepts and intend to measure usability and acceptability, they seem difficult to assess. Terms such as "user friendliness" and "acceptance" were used frequently. User participation in the 29 studies was high. Persons with MCI/D, FCs, and staff/other older adults were involved in focus groups, workshops, and interviews as part of the preimplementation process. Research regarding technologies to support people with MCI/D seems optimistic, and a wide range of technologies has been evaluated in homes with people with MCI/D and their FCs. A major finding was the importance of including people with MCI/D and their FCs in research, in order to learn about required design features to enhance usability and acceptability. Surprisingly, very few studies reported on the consequences of technology use with regard to quality of life, occupational performance, or human dignity.

  5. A usability evaluation exploring the design of American Nurses Association state web sites.

    PubMed

    Alexander, Gregory L; Wakefield, Bonnie J; Anbari, Allison B; Lyons, Vanessa; Prentice, Donna; Shepherd, Marilyn; Strecker, E Bradley; Weston, Marla J

    2014-08-01

    National leaders are calling for opportunities to facilitate the Future of Nursing. Opportunities can be encouraged through state nurses association Web sites, which are part of the American Nurses Association, that are well designed, with appropriate content, and in a language professional nurses understand. The American Nurses Association and constituent state nurses associations provide information about nursing practice, ethics, credentialing, and health on Web sites. We conducted usability evaluations to determine compliance with heuristic and ethical principles for Web site design. We purposefully sampled 27 nursing association Web sites and used 68 heuristic and ethical criteria to perform systematic usability assessments of nurse association Web sites. Web site analysis included seven double experts who were all RNs trained in usability analysis. The extent to which heuristic and ethical criteria were met ranged widely from one state that met 0% of the criteria for "help and documentation" to states that met greater than 92% of criteria for "visibility of system status" and "aesthetic and minimalist design." Suggested improvements are simple yet make an impact on a first-time visitor's impression of the Web site. For example, adding internal navigation and tracking features and providing more details about the application process through help and frequently asked question documentation would facilitate better use. Improved usability will improve effectiveness, efficiency, and consumer satisfaction with these Web sites.

  6. Use of Online Machine Translation for Nursing Literature: A Questionnaire-Based Survey

    PubMed Central

    Anazawa, Ryoko; Ishikawa, Hirono; Takahiro, Kiuchi

    2013-01-01

    Background: The language barrier is a significant obstacle for nurses who are not native English speakers to obtain information from international journals. Freely accessible online machine translation (MT) offers a possible solution to this problem. Aim: To explore how Japanese nursing professionals use online MT and perceive its usability in reading English articles and to discuss what should be considered for better utilisation of online MT lessening the language barrier. Method: In total, 250 randomly selected assistants and research associates at nursing colleges across Japan answered a questionnaire examining the current use of online MT and perceived usability among Japanese nurses, along with the number of articles read in English and the perceived language barrier. The items were rated on Likert scales, and t-test, ANOVA, chi-square test, and Spearman’s correlation were used for analyses. Results: Of the participants, 73.8% had used online MT. More than half of them felt it was usable. The language barrier was strongly felt, and academic degrees and English proficiency level were associated factors. The perceived language barrier was related to the frequency of online MT use. No associated factor was found for the perceived usability of online MT. Conclusion: Language proficiency is an important factor for optimum utilisation of MT. A need for education in the English language, reading scientific papers, and online MT training was indicated. Cooperation with developers and providers of MT for the improvement of their systems is required. PMID:23459140

  7. The Usability Evaluation of Fakih Method Based on Technology for Students with Hearing Difficulties: The User's Retrospective

    ERIC Educational Resources Information Center

    Sabdan, Muhammad Sayuti Bin; Alias, Norlidah; Jomhari, Nazean; Jamaludin, Khairul Azhar; DeWitt, Dorothy

    2014-01-01

    The study is aimed at evaluating the FAKIH method based on technology in teaching al-Quran, based on the user's retrospective. The participants of this study were five students selected based on hearing difficulties. The study employed the user evaluation framework. Teacher's journals were used to determine the frequency and percentage of…

  8. Usability of a CKD Educational Website Targeted to Patients and Their Family Members

    PubMed Central

    Zuckerman, Marni; Fink, Wanda; Hu, Peter; Yang, Shiming; Fink, Jeffrey C.

    2012-01-01

    Summary Background and objectives Web-based technology is critical to the future of healthcare. As part of the Safe Kidney Care cohort study evaluating patient safety in CKD, this study determined how effectively a representative sample of patients with CKD or family members could interpret and use the Safe Kidney Care website (www.safekidneycare.org), an informational website on safety in CKD. Design, setting, participants, & measurements Between November of 2011 and January of 2012, persons with CKD or their family members underwent formal usability testing administered by a single interviewer with a second recording observer. Each participant was independently provided a list of 21 tasks to complete, with each task rated as either easily completed/noncritical error or critical error (user cannot complete the task without significant interviewer intervention). Results Twelve participants completed formal usability testing. Median completion time for all tasks was 17.5 minutes (range=10–44 minutes). In total, 10 participants had greater than or equal to one critical error. There were 55 critical errors in 252 tasks (22%), with the highest proportion of critical errors occurring when participants were asked to find information on treatments that may damage kidneys, find the website on the internet, increase font size, and scroll to the bottom of the webpage. Participants were generally satisfied with the content and usability of the website. Conclusions Web-based educational materials for patients with CKD should target a wide range of computer literacy levels and anticipate variability in competency in use of the computer and internet. PMID:22798537

  9. Evaluating a Pivot-Based Approach for Bilingual Lexicon Extraction

    PubMed Central

    Kim, Jae-Hoon; Kwon, Hong-Seok; Seo, Hyeong-Won

    2015-01-01

    A pivot-based approach for bilingual lexicon extraction is based on the similarity of context vectors represented by words in a pivot language like English. In this paper, in order to show validity and usability of the pivot-based approach, we evaluate the approach in company with two different methods for estimating context vectors: one estimates them from two parallel corpora based on word association between source words (resp., target words) and pivot words and the other estimates them from two parallel corpora based on word alignment tools for statistical machine translation. Empirical results on two language pairs (e.g., Korean-Spanish and Korean-French) have shown that the pivot-based approach is very promising for resource-poor languages and this approach observes its validity and usability. Furthermore, for words with low frequency, our method is also well performed. PMID:25983745

  10. Usability testing of a monitoring and feedback tool to stimulate physical activity.

    PubMed

    van der Weegen, Sanne; Verwey, Renée; Tange, Huibert J; Spreeuwenberg, Marieke D; de Witte, Luc P

    2014-01-01

    A MONITORING AND FEEDBACK TOOL TO STIMULATE PHYSICAL ACTIVITY, CONSISTING OF AN ACTIVITY SENSOR, SMARTPHONE APPLICATION (APP), AND WEBSITE FOR PATIENTS AND THEIR PRACTICE NURSES, HAS BEEN DEVELOPED: the 'It's LiFe!' tool. In this study the usability of the tool was evaluated by technology experts and end users (people with chronic obstructive pulmonary disease or type 2 diabetes, with ages from 40-70 years), to improve the user interfaces and content of the tool. THE STUDY HAD FOUR PHASES: 1) a heuristic evaluation with six technology experts; 2) a usability test in a laboratory by five patients; 3) a pilot in real life wherein 20 patients used the tool for 3 months; and 4) a final lab test by five patients. In both lab tests (phases 2 and 4) qualitative data were collected through a thinking-aloud procedure and video recordings, and quantitative data through questions about task complexity, text comprehensiveness, and readability. In addition, the post-study system usability questionnaire (PSSUQ) was completed for the app and the website. In the pilot test (phase 3), all patients were interviewed three times and the Software Usability Measurement Inventory (SUMI) was completed. After each phase, improvements were made, mainly to the layout and text. The main improvement was a refresh button for active data synchronization between activity sensor, app, and server, implemented after connectivity problems in the pilot test. The mean score on the PSSUQ for the website improved from 5.6 (standard deviation [SD] 1.3) to 6.5 (SD 0.5), and for the app from 5.4 (SD 1.5) to 6.2 (SD 1.1). Satisfaction in the pilot was not very high according to the SUMI. The use of laboratory versus real-life tests and expert-based versus user-based tests revealed a wide range of usability issues. The usability of the It's LiFe! tool improved considerably during the study.

  11. Mobile Applications for Diabetics: A Systematic Review and Expert-Based Usability Evaluation Considering the Special Requirements of Diabetes Patients Age 50 Years or Older

    PubMed Central

    Quade, Mandy; Kirch, Wilhelm

    2014-01-01

    Background A multitude of mhealth (mobile health) apps have been developed in recent years to support effective self-management of patients with diabetes mellitus type 1 or 2. Objective We carried out a systematic review of all currently available diabetes apps for the operating systems iOS and Android. We considered the number of newly released diabetes apps, range of functions, target user groups, languages, acquisition costs, user ratings, available interfaces, and the connection between acquisition costs and user ratings. Additionally, we examined whether the available applications serve the special needs of diabetes patients aged 50 or older by performing an expert-based usability evaluation. Methods We identified relevant keywords, comparative categories, and their specifications. Subsequently, we performed the app review based on the information given in the Google Play Store, the Apple App Store, and the apps themselves. In addition, we carried out an expert-based usability evaluation based on a representative 10% sample of diabetes apps. Results In total, we analyzed 656 apps finding that 355 (54.1%) offered just one function and 348 (53.0%) provided a documentation function. The dominating app language was English (85.4%, 560/656), patients represented the main user group (96.0%, 630/656), and the analysis of the costs revealed a trend toward free apps (53.7%, 352/656). The median price of paid apps was €1.90. The average user rating was 3.6 stars (maximum 5). Our analyses indicated no clear differences in the user rating between free and paid apps. Only 30 (4.6%) of the 656 available diabetes apps offered an interface to a measurement device. We evaluated 66 apps within the usability evaluation. On average, apps were rated best regarding the criterion “comprehensibility” (4.0 out of 5.0), while showing a lack of “fault tolerance” (2.8 out of 5.0). Of the 66 apps, 48 (72.7%) offered the ability to read the screen content aloud. The number of functions was significantly negative correlated with usability. The presence of documentation and analysis functions reduced the usability score significantly by 0.36 and 0.21 points. Conclusions A vast number of diabetes apps already exist, but the majority offer similar functionalities and combine only one to two functions in one app. Patients and physicians alike should be involved in the app development process to a greater extent. We expect that the data transmission of health parameters to physicians will gain more importance in future applications. The usability of diabetes apps for patients aged 50 or older was moderate to good. But this result applied mainly to apps offering a small range of functions. Multifunctional apps performed considerably worse in terms of usability. Moreover, the presence of a documentation or analysis function resulted in significantly lower usability scores. The operability of accessibility features for diabetes apps was quite limited, except for the feature “screen reader”. PMID:24718852

  12. Acceptance and usability of a home-based monitoring tool of health indicators in children of people with dementia: a Proof of Principle (POP) study

    PubMed Central

    Boessen, April BCG; Vermeulen, Joan; de Witte, Luc P

    2017-01-01

    Background Large-scale cohort studies are needed to confirm the relation between dementia and its possible risk factors. The inclusion of people with dementia in research is a challenge, however, children of people with dementia are at risk and are highly motivated to participate in dementia research. For technologies to support home-based data collection during large-scale studies, participants should be able and willing to use technology for a longer period of time. Objective This study investigated acceptance and usability of iVitality, a research platform for home-based monitoring of dementia health indicators, in 151 children of people with dementia and investigated which frequency of measurements is acceptable for them. Methods Participants were randomized to fortnightly or monthly measurements. At baseline and after 3 months, participants completed an online questionnaire regarding the acceptance (Technology Acceptance Model; 38 items) and usability (Post-Study System Usability Questionnaire; 24 items) of iVitality. Items were rated from 1 (I totally disagree) to 7 (I totally agree). Participants were also invited to take part in an online focus group (OFG) after 3 months of follow-up. Descriptive statistics and both two-sample/independent and paired t-tests were used to analyze the online questionnaires and a directed content analysis was used to analyze the OFGs. Results Children of people with dementia accept iVitality after long-term use and evaluate iVitality as a user-friendly, useful, and trusted technology, despite some suggestions for improvement. Overall, mean scores on acceptance and usability were higher than 5 (I somewhat agree), although the acceptance subscales “social influence” and “time” were rated somewhat lower. No significant differences in acceptance and usability were found between both protocol groups. Over time, “affect” significantly increased among participants measuring blood pressure fortnightly. Conclusion iVitality has the potential to be used in large-scale studies for home-based monitoring of health indicators related to the development of dementia. PMID:28814839

  13. Measurement properties and usability of non-contact scanners for measuring transtibial residual limb volume.

    PubMed

    Kofman, Rianne; Beekman, Anna M; Emmelot, Cornelis H; Geertzen, Jan H B; Dijkstra, Pieter U

    2018-06-01

    Non-contact scanners may have potential for measurement of residual limb volume. Different non-contact scanners have been introduced during the last decades. Reliability and usability (practicality and user friendliness) should be assessed before introducing these systems in clinical practice. The aim of this study was to analyze the measurement properties and usability of four non-contact scanners (TT Design, Omega Scanner, BioSculptor Bioscanner, and Rodin4D Scanner). Quasi experimental. Nine (geometric and residual limb) models were measured on two occasions, each consisting of two sessions, thus in total 4 sessions. In each session, four observers used the four systems for volume measurement. Mean for each model, repeatability coefficients for each system, variance components, and their two-way interactions of measurement conditions were calculated. User satisfaction was evaluated with the Post-Study System Usability Questionnaire. Systematic differences between the systems were found in volume measurements. Most of the variances were explained by the model (97%), while error variance was 3%. Measurement system and the interaction between system and model explained 44% of the error variance. Repeatability coefficient of the systems ranged from 0.101 (Omega Scanner) to 0.131 L (Rodin4D). Differences in Post-Study System Usability Questionnaire scores between the systems were small and not significant. The systems were reliable in determining residual limb volume. Measurement systems and the interaction between system and residual limb model explained most of the error variances. The differences in repeatability coefficient and usability between the four CAD/CAM systems were small. Clinical relevance If accurate measurements of residual limb volume are required (in case of research), modern non-contact scanners should be taken in consideration nowadays.

  14. Upgrades to improve the usability, reliability, and spectral range of the MST Thomson scattering diagnostic

    NASA Astrophysics Data System (ADS)

    Kubala, S. Z.; Borchardt, M. T.; Den Hartog, D. J.; Holly, D. J.; Jacobson, C. M.; Morton, L. A.; Young, W. C.

    2016-11-01

    The Thomson scattering diagnostic on MST records both equilibrium and fluctuating electron temperature with a range capability of 10 eV-5 keV. Standard operation with two modified commercial Nd:YAG lasers allows measurements at rates of 1 kHz-25 kHz. Several subsystems of the diagnostic are being improved. The power supplies for the avalanche photodiode detectors (APDs) that record the scattered light are being replaced to improve usability, reliability, and maintainability. Each of the 144 APDs will have an individual rack mounted switching supply, with bias voltage adjustable to match the APD. Long-wavelength filters (1140 nm center, 80 nm bandwidth) have been added to the polychromators to improve capability to resolve non-Maxwellian distributions and to enable directed electron flow measurements. A supercontinuum (SC) pulsed white light source has replaced the tungsten halogen lamp previously used for spectral calibration of the polychromators. The SC source combines substantial brightness produced in nanosecond pulses with a spectrum that covers the entire range of the polychromators.

  15. Upgrades to improve the usability, reliability, and spectral range of the MST Thomson scattering diagnostic.

    PubMed

    Kubala, S Z; Borchardt, M T; Den Hartog, D J; Holly, D J; Jacobson, C M; Morton, L A; Young, W C

    2016-11-01

    The Thomson scattering diagnostic on MST records both equilibrium and fluctuating electron temperature with a range capability of 10 eV-5 keV. Standard operation with two modified commercial Nd:YAG lasers allows measurements at rates of 1 kHz-25 kHz. Several subsystems of the diagnostic are being improved. The power supplies for the avalanche photodiode detectors (APDs) that record the scattered light are being replaced to improve usability, reliability, and maintainability. Each of the 144 APDs will have an individual rack mounted switching supply, with bias voltage adjustable to match the APD. Long-wavelength filters (1140 nm center, 80 nm bandwidth) have been added to the polychromators to improve capability to resolve non-Maxwellian distributions and to enable directed electron flow measurements. A supercontinuum (SC) pulsed white light source has replaced the tungsten halogen lamp previously used for spectral calibration of the polychromators. The SC source combines substantial brightness produced in nanosecond pulses with a spectrum that covers the entire range of the polychromators.

  16. Reproducibility of tumor motion probability distribution function in stereotactic body radiation therapy of lung cancer.

    PubMed

    Zhang, Fan; Hu, Jing; Kelsey, Chris R; Yoo, David; Yin, Fang-Fang; Cai, Jing

    2012-11-01

    To evaluate the reproducibility of tumor motion probability distribution function (PDF) in stereotactic body radiation therapy (SBRT) of lung cancer using cine megavoltage (MV) images. Cine MV images of 20 patients acquired during three-dimensional conformal (6-11 beams) SBRT treatments were retrospectively analyzed to extract tumor motion trajectories. For each patient, tumor motion PDFs were generated per fraction (PDF(n)) using three selected "usable" beams. Patients without at least three usable beams were excluded from the study. Fractional PDF reproducibility (R(n)) was calculated as the Dice similarity coefficient between PDF(n) to a "ground-truth" PDF (PDF(g)), which was generated using the selected beams of all fractions. The mean of R(n), labeled as R(m), was calculated for each patient and correlated to the patient's mean tumor motion rang (A(m)). Change of R(m) during the course of SBRT treatments was also evaluated. Intra- and intersubject coefficient of variation (CV) of R(m) and A(m) were determined. Thirteen patients had at least three usable beams and were analyzed. The mean of R(m) was 0.87 (range, 0.84-0.95). The mean of A(m) was 3.18 mm (range, 0.46-7.80 mm). R(m) was found to decrease as A(m) increases following an equation of R(m) = 0.17e(-0.9Am) + 0.84. R(m) also decreased slightly throughout the course of treatments. Intersubject CV of R(m) (0.05) was comparable to intrasubject CV of R(m) (range, 0.02-0.09); intersubject CV of A(m) (0.73) was significantly greater than intrasubject CV of A(m) (range, 0.09-0.24). Tumor motion PDF can be determined using cine MV images acquired during the treatments. The reproducibility of lung tumor motion PDF decreased exponentially as the tumor motion range increased and decreased slightly throughout the course of the treatments. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. What patients' problems do nurses e-chart? Longitudinal study to evaluate the usability of an interface terminology.

    PubMed

    Juvé-Udina, Maria Eulàlia

    2013-12-01

    The nurses' ability to document patient's status, problems and progress is an important issue in patients' safety. Nursing terminologies are intended to support nursing practice but as any other clinical tool, they should be evaluated to assure quality and warrant effective written communication among clinicians. This study was aimed to evaluate the usability of the diagnosis axis of an interface terminology by assessing its completeness and the frequency of use of its concepts. Observational, longitudinal, multicentre study. A total of 8 hospitals representing 162 acute medical-surgical, obstetric and mental health nursing wards, step-down units and home in-patient units were included. Overall, 246,400 electronic care plans were studied; 53.5% from male patients; 14.6% paediatrics and 33.7% from patients elder than 70 years old. Most were admitted due to cardiocirculatory, respiratory, digestive or musculoskeletal conditions (50.5%), other acute medical or surgical disorders (29.8%) and obstetrics (19.3%). The main outcome measures were: the use of nursing diagnoses from the interface terminology evaluated and their accumulated frequency, analysed over a 3-year retrospective review of the electronic nursing care plans. The analysis of data included descriptive statistics with a confidence level of 95% for confidence intervals. Most of the diagnostic concepts from the interface terminology were used (92.3%) by nurses to illustrate patients' problems in the electronic care plans. Their frequency of use widely varied, from some very frequent diagnoses like Risk for haemorrhage (51.4%; CI 95%: 51.25-51.65) or Acute pain (49.6%; CI: 49.49-49.88) to others used only in exceptional cases like Faecal impaction or Extravasation. The first nursing diagnosis related to family or caregiver emerges in the 32nd place of the ranking. Results for outcome measures oriented that the diagnosis axis of this interface terminology meets the usability criterion of completeness when assessing for the use of its concepts in the acute care setting. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Management of surgical instruments with radio frequency identification tags.

    PubMed

    Kusuda, Kaori; Yamashita, Kazuhiko; Ohnishi, Akiko; Tanaka, Kiyohito; Komino, Masaru; Honda, Hiroshi; Tanaka, Shinichi; Okubo, Takashi; Tripette, Julien; Ohta, Yuji

    2016-01-01

    To prevent malpractices, medical staff has adopted inventory time-outs and/or checklists. Accurate inventory and maintenance of surgical instruments decreases the risk of operating room miscounting and malfunction. In our previous study, an individual management of surgical instruments was accomplished using Radio Frequency Identification (RFID) tags. The purpose of this paper is to evaluate a new management method of RFID-tagged instruments. The management system of RFID-tagged surgical instruments was used for 27 months in clinical areas. In total, 13 study participants assembled surgical trays in the central sterile supply department. While using the management system, trays were assembled 94 times. During this period, no assembly errors occurred. An instrument malfunction had occurred after the 19th, 56th, and 73 th uses, no malfunction caused by the RFID tags, and usage history had been recorded. Additionally, the time it took to assemble surgical trays was recorded, and the long-term usability of the management system was evaluated. The system could record the number of uses and the defective history of each surgical instrument. In addition, the history of the frequency of instruments being transferred from one tray to another was recorded. The results suggest that our system can be used to manage instruments safely. Additionally, the management system was acquired of the learning effect and the usability on daily maintenance. This finding suggests that the management system examined here ensures surgical instrument and tray assembly quality.

  19. Monitoring human health behaviour in one's living environment: a technological review.

    PubMed

    Lowe, Shane A; Ólaighin, Gearóid

    2014-02-01

    The electronic monitoring of human health behaviour using computer techniques has been an active research area for the past few decades. A wide array of different approaches have been investigated using various technologies including inertial sensors, Global Positioning System, smart homes, Radio Frequency IDentification and others. It is only in recent years that research has turned towards a sensor fusion approach using several different technologies in single systems or devices. These systems allow for an increased volume of data to be collected and for activity data to be better used as measures of behaviour. This change may be due to decreasing hardware costs, smaller sensors, increased power efficiency or increases in portability. This paper is intended to act as a reference for the design of multi-sensor behaviour monitoring systems. The range of technologies that have been used in isolation for behaviour monitoring both in research and commercial devices are reviewed and discussed. Filtering, range, sensitivity, usability and other considerations of different technologies are discussed. A brief overview of commercially available activity monitors and their technology is also included. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.

  20. Debunking Health IT Usability Myths

    PubMed Central

    Staggers, N.; Xiao, Y.; Chapman, L.

    2013-01-01

    Poor usability is a threat to patient safety and linked to productivity loss, workflow disruption, user frustration, sub-optimal product use and system de-installations. Although usability is receiving more attention nationally and internationally, myths about usability persist. This editorial debunks five common myths about usability (1) usability only concerns the look and feel of a product and is, therefore, only a minor concern, (2) usability is not measurable, (3) usability stifles innovation, (4) vendors are solely responsible for product usability, and (5) usability methods are not practical for use in healthcare. PMID:23874361

  1. Accessibility of Home Blood Pressure Monitors for Blind and Visually Impaired People

    PubMed Central

    Uslan, Mark M.; Burton, Darren M.; Wilson, Thomas E.; Taylor, Steven; Chertow, Bruce S.; Terry, Jack E.

    2007-01-01

    Background The prevalence of hypertension comorbid with diabetes is a significant health care issue. Use of the home blood pressure monitor (HBPM) for aiding in the control of hypertension is noteworthy because of benefits that accrue from following a home measurement regimen. To be usable by blind and visually impaired patients, HBPMs must have speech output to convey all screen information, an easily readable visual display, identifiable controls that are easy to use, and an accessible user manual. Methods Data on the physical aspects and the features and functions of nine Food and Drug Administration-approved HBPMs (eight of which were recommended by the British Hypertension Society) were tabulated and analyzed for usability by blind and visually impaired individuals. Video Electronics Standards Association standards were used to measure contrast modulation in the displays of the HBPMs. Ten persons who are blind or visually impaired and who have diabetes were surveyed to determine how they monitor their blood pressure and to learn their ideas for improvements in usability. Results Physical controls were found to be easy to identify, and operating procedures were found to be relatively simple on all of the HBPMs, but user manuals were either inaccessible or minimally accessible to blind persons. The two HBPMs that have speech output do not voice all of the information that is displayed on the screen. Some functions that are standard in the HBPMs without speech output, such as the feature for automatically setting cuff inflation volume and memory, were lacking in the HBPMs with speech output. These features were mentioned as desirable in interviews with legally blind persons who are diabetic and who monitor their blood pressure at home. Visual display output was large and adequate in all of the HBPMs. Michelson contrast for numeric digits in the HBPM displays was also measured, ranging from 55 to 75% for characters with dominant spatial frequency components lying in the range of 0.5–1.0 cycles/degree. Conclusions Home blood pressure monitors are easy-to-use devices that do not present accessibility barriers that are difficult to surmount, either technically or operationally. Two HBPMs with voice output were found to have a significant degree of accessibility, but they were not found to offer as many features as those HBPMs that were less accessible. Recommendations were made to improve accessibility, including the development of visual display standards that specify a minimally acceptable level of Michelson contrast. PMID:19888410

  2. State of the (net)work address Developing criteria for applying social networking to the work environment.

    PubMed

    Valdez, André Calero; Schaar, Anne Kathrin; Ziefle, Martina

    2012-01-01

    In an increasingly faster paced innovative world, maintaining the ability to innovate in spite of an aging work force will become every company's strongest leverage for success. Tapping the latent knowledge resources and creativity of overlooked employees and persisting crucial information for business conduct are promising results for social networking sites (SNS) in a working context. Usability and usefulness are exponential factors in creating a successful SNS. In order to make a SNS usable for a heterogeneous user group, analyses of user diversity in regard to social media need to be done. Furthermore differences in communication medium and frequency in regard to age, content, hierarchy position, departmental thresholds and company size need to be analyzed. For analysis purposes both qualitative and quantitative research methods were applied. Strong effects of age and communication content were found in survey with 194 participants.

  3. Design concept for pressure switch calibrator

    NASA Technical Reports Server (NTRS)

    Slingerland, M. G.

    1966-01-01

    Calibrator and switch design enables pressure switches to operate under 150 g shock loads. The design employs a saturated liquid-to-vapor phase transition at constant pressure to produce a known force independent of displacement over a usable range.

  4. Usability of a patient education and motivation tool using heuristic evaluation.

    PubMed

    Joshi, Ashish; Arora, Mohit; Dai, Liwei; Price, Kathleen; Vizer, Lisa; Sears, Andrew

    2009-11-06

    Computer-mediated educational applications can provide a self-paced, interactive environment to deliver educational content to individuals about their health condition. These programs have been used to deliver health-related information about a variety of topics, including breast cancer screening, asthma management, and injury prevention. We have designed the Patient Education and Motivation Tool (PEMT), an interactive computer-based educational program based on behavioral, cognitive, and humanistic learning theories. The tool is designed to educate users and has three key components: screening, learning, and evaluation. The objective of this tutorial is to illustrate a heuristic evaluation using a computer-based patient education program (PEMT) as a case study. The aims were to improve the usability of PEMT through heuristic evaluation of the interface; to report the results of these usability evaluations; to make changes based on the findings of the usability experts; and to describe the benefits and limitations of applying usability evaluations to PEMT. PEMT was evaluated by three usability experts using Nielsen's usability heuristics while reviewing the interface to produce a list of heuristic violations with severity ratings. The violations were sorted by heuristic and ordered from most to least severe within each heuristic. A total of 127 violations were identified with a median severity of 3 (range 0 to 4 with 0 = no problem to 4 = catastrophic problem). Results showed 13 violations for visibility (median severity = 2), 38 violations for match between system and real world (median severity = 2), 6 violations for user control and freedom (median severity = 3), 34 violations for consistency and standards (median severity = 2), 11 violations for error severity (median severity = 3), 1 violation for recognition and control (median severity = 3), 7 violations for flexibility and efficiency (median severity = 2), 9 violations for aesthetic and minimalist design (median severity = 2), 4 violations for help users recognize, diagnose, and recover from errors (median severity = 3), and 4 violations for help and documentation (median severity = 4). We describe the heuristic evaluation method employed to assess the usability of PEMT, a method which uncovers heuristic violations in the interface design in a quick and efficient manner. Bringing together usability experts and health professionals to evaluate a computer-mediated patient education program can help to identify problems in a timely manner. This makes this method particularly well suited to the iterative design process when developing other computer-mediated health education programs. Heuristic evaluations provided a means to assess the user interface of PEMT.

  5. Usability of a Patient Education and Motivation Tool Using Heuristic Evaluation

    PubMed Central

    Arora, Mohit; Dai, Liwei; Price, Kathleen; Vizer, Lisa; Sears, Andrew

    2009-01-01

    Background Computer-mediated educational applications can provide a self-paced, interactive environment to deliver educational content to individuals about their health condition. These programs have been used to deliver health-related information about a variety of topics, including breast cancer screening, asthma management, and injury prevention. We have designed the Patient Education and Motivation Tool (PEMT), an interactive computer-based educational program based on behavioral, cognitive, and humanistic learning theories. The tool is designed to educate users and has three key components: screening, learning, and evaluation. Objective The objective of this tutorial is to illustrate a heuristic evaluation using a computer-based patient education program (PEMT) as a case study. The aims were to improve the usability of PEMT through heuristic evaluation of the interface; to report the results of these usability evaluations; to make changes based on the findings of the usability experts; and to describe the benefits and limitations of applying usability evaluations to PEMT. Methods PEMT was evaluated by three usability experts using Nielsen’s usability heuristics while reviewing the interface to produce a list of heuristic violations with severity ratings. The violations were sorted by heuristic and ordered from most to least severe within each heuristic. Results A total of 127 violations were identified with a median severity of 3 (range 0 to 4 with 0 = no problem to 4 = catastrophic problem). Results showed 13 violations for visibility (median severity = 2), 38 violations for match between system and real world (median severity = 2), 6 violations for user control and freedom (median severity = 3), 34 violations for consistency and standards (median severity = 2), 11 violations for error severity (median severity = 3), 1 violation for recognition and control (median severity = 3), 7 violations for flexibility and efficiency (median severity = 2), 9 violations for aesthetic and minimalist design (median severity = 2), 4 violations for help users recognize, diagnose, and recover from errors (median severity = 3), and 4 violations for help and documentation (median severity = 4). Conclusion We describe the heuristic evaluation method employed to assess the usability of PEMT, a method which uncovers heuristic violations in the interface design in a quick and efficient manner. Bringing together usability experts and health professionals to evaluate a computer-mediated patient education program can help to identify problems in a timely manner. This makes this method particularly well suited to the iterative design process when developing other computer-mediated health education programs. Heuristic evaluations provided a means to assess the user interface of PEMT. PMID:19897458

  6. Investigation of radar backscattering from second-year sea ice

    NASA Technical Reports Server (NTRS)

    Lei, Guang-Tsai; Moore, Richard K.; Gogineni, S. P.

    1988-01-01

    The scattering properties of second-year ice were studied in an experiment at Mould Bay in April 1983. Radar backscattering measurements were made at frequencies of 5.2, 9.6, 13.6, and 16.6 GHz for vertical polarization, horizontal polarization and cross polarizations, with incidence angles ranging from 15 to 70 deg. The results indicate that the second-year ice scattering characteristics were different from first-year ice and also different from multiyear ice. The fading properties of radar signals were studied and compared with experimental data. The influence of snow cover on sea ice can be evaluated by accounting for the increase in the number of independent samples from snow volume with respect to that for bare ice surface. A technique for calculating the snow depth was established by this principle and a reasonable agreement has been observed. It appears that this is a usable way to measure depth in snow or other snow-like media using radar.

  7. Design and Characterization of the UTIAS Anechoic Wind Tunnel

    NASA Astrophysics Data System (ADS)

    Chow, Derrick H. F.

    The anechoic open-jet wind tunnel facility at the University of Toronto Institute for Aerospace Studies was updated and characterized to meet the needs of current and future aeroacoustic experiments. The wind tunnel inlet was resurfaced and flow-conditioning screens were redesigned to improve the freestream turbulence intensity to below 0.4% in the test section. The circular nozzle was replaced with a square secondary contraction that increased the maximum test section velocity to 75 m/s and improved flow uniformity to over 99% across a usable cross-sectional area of 500 mm x 500 mm. Acoustic baffles were installed in front of the wind tunnel inlet and foam wedges were installed in the anechoic chamber. The overall background sound pressure levels in the chamber were improved by 8-18 db over the range of operational freestream velocities. The anechoic chamber cut-off frequency is 170 Hz and the reverberation time for a 60 dB sound power decay is 0.032 s.

  8. Development of a flexible and bendable vibrotactile actuator based on wave-shaped poly(vinyl chloride)/acetyl tributyl citrate gels for wearable electronic devices

    NASA Astrophysics Data System (ADS)

    Park, Won-Hyeong; Bae, Jin Woo; Shin, Eun-Jae; Kim, Sang-Youn

    2016-11-01

    The paradigm of consumer electronic devices is being shifted from rigid hand-held devices to flexible/wearable devices in search of benefits such as enhanced usability and portability, excellent wear characteristics, and more functions in less space. However, the fundamental incompatibility of flexible/wearable devices and a rigid actuator brought forth a new issue obstructing commercialization of flexible/wearable devices. In this paper, we propose a new wave-shaped eco-friendly PVC gel, and a new flexible and bendable vibrotactile actuator that could easily be applied to wearable electronic devices. We explain the vibration mechanism of the proposed vibrotactile actuator and investigate its influence on the content of plasticizer for the performance of the proposed actuator. An experiment for measuring vibrational amplitude was conducted over a wide frequency range. The experiment clearly showed that the proposed vibrotactile actuator could create a variety of haptic sensations in wearable devices.

  9. Adaptive Strategies and Person-Environment Fit among Functionally Limited Older Adults Aging in Place: A Mixed Methods Approach

    PubMed Central

    Lien, Laura L.; Steggell, Carmen D.; Iwarsson, Susanne

    2015-01-01

    Older adults prefer to age in place, necessitating a match between person and environment, or person-environment (P-E) fit. In occupational therapy practice, home modifications can support independence, but more knowledge is needed to optimize interventions targeting the housing situation of older adults. In response, this study aimed to explore the accessibility and usability of the home environment to further understand adaptive environmental behaviors. Mixed methods data were collected using objective and perceived indicators of P-E fit among 12 older adults living in community-dwelling housing. Quantitative data described objective P-E fit in terms of accessibility, while qualitative data explored perceived P-E fit in terms of usability. While accessibility problems were prevalent, participants’ perceptions of usability revealed a range of adaptive environmental behaviors employed to meet functional needs. A closer examination of the P-E interaction suggests that objective accessibility does not always stipulate perceived usability, which appears to be malleable with age, self-perception, and functional competency. Findings stress the importance of evaluating both objective and perceived indicators of P-E fit to provide housing interventions that support independence. Further exploration of adaptive processes in older age may serve to deepen our understanding of both P-E fit frameworks and theoretical models of aging well. PMID:26404352

  10. Effectiveness and usability of Scanning Wizard software: a tool for enhancing switch scanning.

    PubMed

    Koester, Heidi Horstmann; Simpson, Richard C

    2017-11-24

    Scanning Wizard software helps scanning users improve the setup of their switch and scanning system. This study evaluated Scanning Wizard's effectiveness and usability. Ten people who use switch scanning and ten practitioners used Scanning Wizard in the initial session. Usability was high, based on survey responses averaging over 4.5 out of 5, and qualitative feedback was very positive. Five switch users were able to complete the multi-week protocol, using settings on their own scanning system that were recommended from the Scanning Wizard session. Using these revised settings, text entry rates improved by an average of 71%, ranging from 29% to 172% improvement. Results suggest that Scanning Wizard is a useful tool for improving the configuration of scanning systems for people who use switch scanning to communicate. Implications for Rehabilitation Some individuals with severe physical impairments use switch scanning for spoken and written communication. Scanning Wizard software helps scanning users improve the setup of their switch and scanning system. This study demonstrated high usability of Scanning Wizard (with 10 switch userpractitioner teams) and increased text entry rate by an average of 71% (for five switch users). Results suggest that Scanning Wizard is a useful tool for improving the configuration of scanning systems for people who use switch scanning to communicate.

  11. A Multicentre Audit of Single-Use Surgical Instruments (SUSI) for Tonsillectomy and Adenoidectomy

    PubMed Central

    O'Flynn, P; Silva, S; Kothari, P; Persaud, R

    2007-01-01

    INTRODUCTION Prions are resistant to conventional sterilisation procedures and, therefore, could be transmitted iatrogenically through re-usable adenoid and tonsil surgical instruments. Using disposable instruments would avoid the risk of transmission. We present the results of a complete audit loop using BBraun single-use surgical instruments (SUSI). PATIENTS AND METHODS This was a prospective multicentre audit. Surgeons were asked to fill in a standardised questionnaire recording details including postoperative complications, and evaluation of each piece of equipment compared with their own experience of conventional re-usable instruments. In the first cycle, constructive criticisms of the instruments were noted and the manufacturers modified the instruments accordingly. A second cycle of audit was subsequently undertaken. RESULTS A total of 86 patients were audited in the first cycle and 97 in the second cycle. Postoperative haemorrhage rate for both cycles was well within acceptable range. In the first audit cycle, surgeons generally found the Draffin rods, Boyle-Davis gag and bipolar diathermy forceps of poor quality and difficult to use. These were redesigned and, on repeat evaluation during the second audit cycle, were found to be just as good, if not better, than the re-usable instruments. CONCLUSIONS This study suggests that SUSI may be just as good as re-usable instruments. Furthermore, they may be more cost effective. PMID:18201478

  12. Adaptive Strategies and Person-Environment Fit among Functionally Limited Older Adults Aging in Place: A Mixed Methods Approach.

    PubMed

    Lien, Laura L; Steggell, Carmen D; Iwarsson, Susanne

    2015-09-23

    Older adults prefer to age in place, necessitating a match between person and environment, or person-environment (P-E) fit. In occupational therapy practice, home modifications can support independence, but more knowledge is needed to optimize interventions targeting the housing situation of older adults. In response, this study aimed to explore the accessibility and usability of the home environment to further understand adaptive environmental behaviors. Mixed methods data were collected using objective and perceived indicators of P-E fit among 12 older adults living in community-dwelling housing. Quantitative data described objective P-E fit in terms of accessibility, while qualitative data explored perceived P-E fit in terms of usability. While accessibility problems were prevalent, participants' perceptions of usability revealed a range of adaptive environmental behaviors employed to meet functional needs. A closer examination of the P-E interaction suggests that objective accessibility does not always stipulate perceived usability, which appears to be malleable with age, self-perception, and functional competency. Findings stress the importance of evaluating both objective and perceived indicators of P-E fit to provide housing interventions that support independence. Further exploration of adaptive processes in older age may serve to deepen our understanding of both P-E fit frameworks and theoretical models of aging well.

  13. How do health service professionals consider human factors when purchasing interactive medical devices? A qualitative interview study.

    PubMed

    Vincent, Christopher James; Blandford, Ann

    2017-03-01

    We present findings of a UK study into how those involved in purchasing interactive medical devices go about evaluating usability, the challenges that arise, and opportunities for improvement. The study focused on procurement of infusion devices because these are used by various professionals across healthcare. A semi-structured interview study was carried out involving a range of stakeholders (20 in total) involved in or impacted by medical device procurement. Data was analysed using thematic analysis, a qualitative method designed to support the identification, analysis and reporting of patterns. In principle, health service purchasing was found to accommodate consideration of equipment usability. In practice, the evaluation process was driven primarily by engineering standards; assessment of local needs did not accommodate substantive assessment of usability; and choice was limited by the availability of equipment on the marketplace. We discuss ways in which purchasing could be improved through techniques that account for social circumstances. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Examining Older Adults’ Perceptions of Usability and Acceptability of Remote Monitoring Systems to Manage Chronic Heart Failure

    PubMed Central

    Evangelista, Lorraine S.; Moser, Debra K.; Lee, Jung-Ah; Moore, Alison A.; Ghasemzadeh, Hassan; Sarrafzadeh, Majid; Mangione, Carol M.

    2015-01-01

    Objective: This study was conducted to evaluate the feasibility, usability, and acceptability of using remote monitoring systems (RMS) in monitoring health status (e.g., vital signs, symptom distress) in older adults (≥55) with chronic heart failure (HF). Method: Twenty-one patients (52.4% women, mean age 73.1 ± 9.3) were trained to measure and transmit health data with an RMS. Data transmissions were tracked for 12 weeks. Results: All participants initiated use of RMS within 1 week; 71%, 14%, and 14% of patients transmitted daily health data 100%, ≥75%, and <75% of the time, respectively, for 12 weeks. Overall usability and acceptability of the RMS were 4.08 ± 0.634 and 4.10 ± 0.563, respectively (when scored on a range of 1-5, where 1 = strongly disagree and 5 = strongly agree). Discussion: Findings show that an RMS-based intervention can be successfully implemented in a group of older patients with chronic HF. PMID:28138479

  15. Palliative Care Planner: A Pilot Study to Evaluate Acceptability and Usability of an Electronic Health Records System-integrated, Needs-targeted App Platform.

    PubMed

    Cox, Christopher E; Jones, Derek M; Reagan, Wen; Key, Mary D; Chow, Vinca; McFarlin, Jessica; Casarett, David; Creutzfeldt, Claire J; Docherty, Sharron L

    2018-01-01

    The quality and patient-centeredness of intensive care unit (ICU)-based palliative care delivery is highly variable. To develop and pilot an app platform for clinicians and ICU patients and their family members that enhances the delivery of needs-targeted palliative care. In the development phase of the study, we developed an electronic health record (EHR) system-integrated mobile web app system prototype, PCplanner (Palliative Care Planner). PCplanner screens the EHR for ICU patients meeting any of five prompts (triggers) for palliative care consultation, allows families to report their unmet palliative care needs, and alerts clinicians to these needs. The evaluation phase included a prospective before/after study conducted at a large academic medical center. Two control populations were enrolled in the before period to serve as context for the intervention. First, 25 ICU patients who received palliative care consults served as patient-level controls. Second, 49 family members of ICU patients who received mechanical ventilation for at least 48 hours served as family-level controls. Afterward, 14 patients, 18 family members, and 10 clinicians participated in the intervention evaluation period. Family member outcomes measured at baseline and 4 days later included acceptability (Client Satisfaction Questionnaire [CSQ]), usability (Systems Usability Scale [SUS]), and palliative care needs, assessed with the adapted needs of social nature, existential concerns, symptoms, and therapeutic interaction (NEST) scale; the Patient-Centeredness of Care Scale (PCCS); and the Perceived Stress Scale (PSS). Patient outcomes included frequency of goal concordant treatment, hospital length of stay, and discharge disposition. Family members reported high PCplanner acceptability (mean CSQ, 14.1 [SD, 1.4]) and usability (mean SUS, 21.1 [SD, 1.7]). PCplanner family member recipients experienced a 12.7-unit reduction in NEST score compared with a 3.4-unit increase among controls (P = 0.002), as well as improved mean scores on the PCCS (6.6 [SD, 5.8]) and the PSS (-0.8 [SD, 1.9]). The frequency of goal-concordant treatment increased over the course of the intervention (n = 14 [SD, 79%] vs. n = 18 [SD, 100%]). Compared with palliative care controls, intervention patients received palliative care consultation sooner (3.9 [SD, 2.7] vs. 6.9 [SD, 7.1] mean days), had a shorter mean hospital length of stay (20.5 [SD, 9.1] vs. 22.3 [SD, 16.0] patient number), and received hospice care more frequently (5 [36%] vs. 5 [20%]), although these differences were not statistically significant. PCplanner represents an acceptable, usable, and clinically promising systems-based approach to delivering EHR-triggered, needs-targeted ICU-based palliative care within a standard clinical workflow. A clinical trial in a larger population is needed to evaluate its efficacy.

  16. Algorithm of resonance orders for the objects

    NASA Astrophysics Data System (ADS)

    Zhang, YongGang; Zhang, JianXue

    2018-03-01

    In mechanical engineering, the object resonance phenomena often occur when the external incident wave frequency is close to object of the natural frequency. Object resonance phenomena get the maximum value when the external incident frequency is equal to object the natural frequency. Experiments found that resonance intension of the object is changed, different objects resonance phenomena present different characteristics of ladders. Based on object orders resonance characteristics, the calculation method of object orders resonance is put forward in the paper, and the application for the light and sound waves on the seven order resonance characteristics by people feel, the result error is less than 1%.Visible in this paper, the method has high accuracy and usability. The calculation method reveals that some object resonance occur present order characteristic only four types, namely the first-orders resonance characteristics, third-orders characteristics, five orders characteristic, and seven orders characteristic.

  17. A knowledge translation intervention to enhance clinical application of a virtual reality system in stroke rehabilitation.

    PubMed

    Levac, Danielle; Glegg, Stephanie M N; Sveistrup, Heidi; Colquhoun, Heather; Miller, Patricia A; Finestone, Hillel; DePaul, Vincent; Harris, Jocelyn E; Velikonja, Diana

    2016-10-06

    Despite increasing evidence for the effectiveness of virtual reality (VR)-based therapy in stroke rehabilitation, few knowledge translation (KT) resources exist to support clinical integration. KT interventions addressing known barriers and facilitators to VR use are required. When environmental barriers to VR integration are less amenable to change, KT interventions can target modifiable barriers related to therapist knowledge and skills. A multi-faceted KT intervention was designed and implemented to support physical and occupational therapists in two stroke rehabilitation units in acquiring proficiency with use of the Interactive Exercise Rehabilitation System (IREX; GestureTek). The KT intervention consisted of interactive e-learning modules, hands-on workshops and experiential practice. Evaluation included the Assessing Determinants of Prospective Take Up of Virtual Reality (ADOPT-VR) Instrument and self-report confidence ratings of knowledge and skills pre- and post-study. Usability of the IREX was measured with the System Usability Scale (SUS). A focus group gathered therapist experiences. Frequency of IREX use was recorded for 6 months post-study. Eleven therapists delivered a total of 107 sessions of VR-based therapy to 34 clients with stroke. On the ADOPT-VR, significant pre-post improvements in therapist perceived behavioral control (p = 0.003), self-efficacy (p = 0.005) and facilitating conditions (p =0.019) related to VR use were observed. Therapist intention to use VR did not change. Knowledge and skills improved significantly following e-learning completion (p = 0.001) and was sustained 6 months post-study. Below average perceived usability of the IREX (19 th percentile) was reported. Lack of time was the most frequently reported barrier to VR use. A decrease in frequency of perceived barriers to VR use was not significant (p = 0.159). Two therapists used the IREX sparingly in the 6 months following the study. Therapists reported that client motivation to engage with VR facilitated IREX use in practice but that environmental and IREX-specific barriers limited use. Despite increased knowledge and skills in VR use, the KT intervention did not alter the number of perceived barriers to VR use, intention to use or actual use of VR. Poor perceived system usability had an impact on integration of this particular VR system into clinical practice.

  18. Quality of online health information about oral contraceptives from Hebrew-language websites.

    PubMed

    Neumark, Yehuda; Flum, Lior; Lopez-Quintero, Catalina; Shtarkshall, Ronny

    2012-09-24

    The Internet is a frequently used source of health information. Adolescents in particular seem to be receptive to online health information (OHI) and often incorporate such information in their decision-making processes. Yet, OHI is often incomplete, inaccurate, or unreliable. This study assessed the quality of Hebrew online (non-user-generated) content on oral contraceptives (OC), with regard to accuracy/completeness, credibility, and usability. Twenty-nine websites in Hebrew, including those of the four Israeli HMOs, were identified and evaluated. The websites were categorized as: HMO, health portal, contraception-specific, promotional-commercial, and life style and women's health. A set of established content parameters was selected by a family planning expert to assess accuracy/completeness. The Health on the Net Foundation Code of Conduct (HONcode) principles were used to assess the websites' reliability. Usability was assessed by applying items selected from the Minervation Validation and the University of Michigan's 'Website Evaluation checklist' scale. Mean scores, standard deviations (SD), and ranges were calculated for all websites and for category-specific websites. Correlation between dimensions and Inter-rater reliability were also examined. The mean score for accuracy/completeness was 50.9% for all websites (SD=30.1%, range 8-100%). Many websites failed to provide complete information, or provided inaccurate information regarding what to do when a pill is missed and when to use back-up methods. The average credibility score for all websites was 70.6% (SD=15.1, range=38=98%). The credibility parameters that were most commonly absent were funding source, authoring, date of content creation and last modification, explicit reference to evidence-based information, and references and citations. The average usability score for all websites was 94.5% (SD=6.9%, range 79-100%). A weak correlation was found between the three quality parameters assessed. Wide variation was noted in the quality of Hebrew-language OC websites. HMOs' websites scored highest on credibility and usability, and contraceptive-specific websites exhibited the greatest accuracy/completeness. The findings highlight the need to establish quality guidelines for health website content, train health care providers in assisting their patients to seek high quality OHI, and strengthen e-health literacy skills among online-information seekers, including perhaps health professionals.

  19. Second Version of Google Glass as a Wearable Socio-Affective Aid: Positive School Desirability, High Usability, and Theoretical Framework in a Sample of Children with Autism

    PubMed Central

    Keshav, Neha U; Salisbury, Joseph P; Vahabzadeh, Arshya

    2018-01-01

    Background Computerized smartglasses are being developed as an assistive technology for daily activities in children and adults with autism spectrum disorder (ASD). While smartglasses may be able to help with educational and behavioral needs, their usability and acceptability in children with ASD is largely unknown. There have been reports of negative social perceptions surrounding smartglasses use in mainstream populations, a concern given that assistive technologies may already carry their own stigma. Children with ASD may also have a range of additional behavioral, developmental, and social challenges when asked to use this emerging technology in school and home settings. Objective The usability and acceptability of Glass Enterprise Edition (Glass), the successor to Google Glass smartglasses, were explored in children with ASD and their caregivers. Methods Eight children with ASD and their caregivers were recruited to attend a demonstration session with Glass smartglasses the week they were publicly released. The children had a wide range of ability, including limited speech to speaking, and represented a full range of school ages (6 to 17 years). Children and caregivers were interviewed about their experience of using the smartglasses and whether they would use them at school and home. Results All 8 children succeeded in using Glass and did not feel stressed (8/8, 100%) or experience any overwhelming sensory or emotional issues during the session (8/8, 100%). All 8 children (8/8, 100%) endorsed that they would be willing to wear and use the device in both home and school settings. Caregivers felt the experience was fun for the children (8/8, 100%), and most caregivers felt the experience was better than they had expected (6/8, 75%). Conclusions A wide age and ability range of children with ASD used Glass immediately after it was released and found it to be usable and acceptable. Despite concerns about potential stigma or social acceptability, all of the children were prepared to use the technology in both home and school settings. Encouragingly, most caregivers noted a very positive response. There were no behavioral, developmental, or social- or stigma-related concerns during or after the session. Smartglasses may be a useful future technology for children with ASD and are readily accepted for use by children with ASD and their caregivers. PMID:29301738

  20. Quality of online health information about oral contraceptives from Hebrew-language websites

    PubMed Central

    2012-01-01

    Background The Internet is a frequently used source of health information. Adolescents in particular seem to be receptive to online health information (OHI) and often incorporate such information in their decision-making processes. Yet, OHI is often incomplete, inaccurate, or unreliable. This study assessed the quality of Hebrew online (non-user-generated) content on oral contraceptives (OC), with regard to accuracy/completeness, credibility, and usability. Methods Twenty-nine websites in Hebrew, including those of the four Israeli HMOs, were identified and evaluated. The websites were categorized as: HMO, health portal, contraception-specific, promotional-commercial, and life style and women’s health. A set of established content parameters was selected by a family planning expert to assess accuracy/completeness. The Health on the Net Foundation Code of Conduct (HONcode) principles were used to assess the websites’ reliability. Usability was assessed by applying items selected from the Minervation Validation and the University of Michigan’s ′Website Evaluation checklist′ scale. Mean scores, standard deviations (SD), and ranges were calculated for all websites and for category-specific websites. Correlation between dimensions and Inter-rater reliability were also examined. Results The mean score for accuracy/completeness was 50.9% for all websites (SD=30.1%, range 8–100%). Many websites failed to provide complete information, or provided inaccurate information regarding what to do when a pill is missed and when to use back–up methods. The average credibility score for all websites was 70.6% (SD=15.1, range=38=98%). The credibility parameters that were most commonly absent were funding source, authoring, date of content creation and last modification, explicit reference to evidence-based information, and references and citations. The average usability score for all websites was 94.5% (SD=6.9%, range 79–100%). A weak correlation was found between the three quality parameters assessed. Conclusions Wide variation was noted in the quality of Hebrew-language OC websites. HMOs’ websites scored highest on credibility and usability, and contraceptive-specific websites exhibited the greatest accuracy/completeness. The findings highlight the need to establish quality guidelines for health website content, train health care providers in assisting their patients to seek high quality OHI, and strengthen e-health literacy skills among online-information seekers, including perhaps health professionals. PMID:23006798

  1. Usability of Videogame-Based Dexterity Training in the Early Rehabilitation Phase of Stroke Patients: A Pilot Study.

    PubMed

    Vanbellingen, Tim; Filius, Suzanne J; Nyffeler, Thomas; van Wegen, Erwin E H

    2017-01-01

    Approximately 70-80% of stroke survivors have limited activities of daily living, mainly due to dexterous problems. Videogame-based training (VBT) along with virtual reality seems to be beneficial to train upper limb function. To evaluate the usability of VBT using the Leap Motion Controller (LMC) to train fine manual dexterity in the early rehabilitation phase of stroke patients as an add-on to conventional therapy. Additionally, this study aimed to estimate the feasibility and potential efficacy of the VBT. During 3 months, 64 stroke patients were screened for eligibility, 13 stroke patients were included (4 women and 9 men; age range: 24-91 years; mean time post stroke: 28.2 days). Nine sessions of 30 min VBT, three times per week as an add-on to conventional therapy with stroke inpatients. Primary outcome was the usability of the system measured with the System Usability Scale. Secondary outcomes concerning feasibility were the compliance rate calculated from the total time spent on the intervention (TT) compared to planned time, the opinion of participants via open-end questions, and the level of active participation measured with the Pittsburgh Rehabilitation Participation Scale. Regarding the potential efficacy secondary outcomes were: functional dexterity measured with the Nine Hole Peg Test (NHPT), subjective dexterity measured with the Dexterity Questionnaire 24, grip strength measured with the Jamar dynamometer, and motor impairment of the upper limb measured with the Fugl-Meyer Upper Extremity (FM-UE) scale. Primarily, the usability of the system was good to excellent. The patient's perception of usability remained stable over a mean period of 3 weeks of VBT. Secondly, the compliance rate was good, and the level of active participation varied between good and very good. The opinion of the participants revealed that despite individual differences, the overall impression of the therapy and device was good. Patients showed significant improvements in hand dexterity. No changes were found in motor impairment of the upper limb (FM-UE) during intervention. VBT using LMC is a usable rehabilitation tool to train dexterity in the early rehabilitation phase of stroke inpatients.

  2. The range and distribution of shortleaf pine in Missouri

    Treesearch

    Franklin G. Liming

    1946-01-01

    Shortleaf pine is one of the most valuable timber species in Missouri and, within its present and potential range, should have an important role in the restoration of the productivity of the forests. The pine will produce more stems per acre, greater merchantable lengths, and consequently a greater volume of usable wood per acre than the associated hardwood species. It...

  3. Construction and performance characteristics of new ion selective electrodes based on carbon nanotubes for determination of meclofenoxate hydrochloride.

    PubMed

    El-Nashar, Rasha M; Abdel Ghani, Nour T; Hassan, Sherif M

    2012-06-12

    This work offers construction and comparative evaluation the performance characteristics of conventional polymer (I), carbon paste (II) and carbon nanotubes chemically modified carbon paste ion selective electrodes (III) for meclofenoxate hydrochloride are described. These electrodes depend mainly on the incorporation of the ion pair of meclofenoxate hydrochloride with phosphomolybdic acid (PMA) or phosphotungestic acid (PTA). They showed near Nernestian responses over usable concentration range 1.0 × 10(-5) to 1.0 × 10(-2)M with slopes in the range 55.15-59.74 mV(concentrationdecade)(-1). These developed electrodes were fully characterized in terms of their composition, response time, working concentration range, life span, usable pH and temperature range. The electrodes showed a very good selectivity for Meclo with respect to a large number of inorganic cations, sugars and in the presence of the degradation product of the drug (p-chloro phenoxy acetic acid). The standard additions method was applied to the determination of MecloCl in pure solution, pharmaceutical preparations and biological samples. Dissolution testing was also applied using the proposed sensors. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Magnitude and frequency of floods in the United States. Part 13. Snake River basin

    USGS Publications Warehouse

    Thomas, C.A.; Broom, H.C.; Cummans, J.E.

    1963-01-01

    The magnitude of a flood of any selected frequency up to 50 years for any site on any stream in the Snake River basin can be determined by methods outlined in this report, with some limitations. The methods are not applicable for regulated streams, for drainage basins smaller than 10 or larger than 5,000 square miles, for streams fed by large springs, or for streams that have flow characteristics materially different from the regional pattern. The magnitude of a flood for a selected frequency at a given site is determined by using the appropriate composite frequency curve and the mean annual flood for the given site. The mean annual flood is computed from either a formula or a nomograph in which drainage area, mean annual precipitation, and a geographic factor are used as independent variables. The standard error of estimate for the computation of mean annual floods is plus 17 percent and minus 15 percent.Nine flood-frequency regions (A-I) are defined. In all except regions B and I, frequency relations vary with the mean altitude of the basin as well as with the geographic location; therefore, families of curves are required for 7 of the 9 flood-frequency regions.The report includes a brief description of the physiography and climate of the Snake River basin to explain the reason for the large variation in mean annual floods, which range from zero to about 27 cubic feet per second per square mile.Composite frequency curves and formulas for computing mean annual floods are based on all suitable flood data collected in the Snake River basin. Tables show the data used to derive the formula. Following the analysis of data are station descriptions and lists of peak stages and discharges for 295 gaging stations at which 5 or more years of annual flood records were collected pr'or to Sept. 30, 1957. Many flood peak data are not usable in defining the frequency curves and deriving the formula because of large diversions and regulation upstream from the gaging stations.

  5. Detrimental Effect Elimination of Laser Frequency Instability in Brillouin Optical Time Domain Reflectometer by Using Self-Heterodyne Detection

    PubMed Central

    Li, Yongqian; Li, Xiaojuan; An, Qi; Zhang, Lixin

    2017-01-01

    A useful method for eliminating the detrimental effect of laser frequency instability on Brillouin signals by employing the self-heterodyne detection of Rayleigh and Brillouin scattering is presented. From the analysis of Brillouin scattering spectra from fibers with different lengths measured by heterodyne detection, the maximum usable pulse width immune to laser frequency instability is obtained to be about 4 µs in a self-heterodyne detection Brillouin optical time domain reflectometer (BOTDR) system using a broad-band laser with low frequency stability. Applying the self-heterodyne detection of Rayleigh and Brillouin scattering in BOTDR system, we successfully demonstrate that the detrimental effect of laser frequency instability on Brillouin signals can be eliminated effectively. Employing the broad-band laser modulated by a 130-ns wide pulse driven electro-optic modulator, the observed maximum errors in temperatures measured by the local heterodyne and self-heterodyne detection BOTDR systems are 7.9 °C and 1.2 °C, respectively. PMID:28335508

  6. A continuous usability evaluation of an electronic medication administration record application.

    PubMed

    Vicente Oliveros, Noelia; Gramage Caro, Teresa; Pérez Menéndez-Conde, Covadonga; Álvarez-Diaz, Ana María; Martín-Aragón Álvarez, Sagrario; Bermejo Vicedo, Teresa; Delgado Silveira, Eva

    2017-12-01

    The complexity of an electronic medication administration record (eMAR) has been underestimated by most designers in the past. Usability issues, such as poorly designed user application flow in eMAR, are therefore of vital importance, since they can have a negative impact on nursing activities and result in poor outcomes. The purpose of this study was to evaluate the usability of an eMAR application during its development. A usability evaluation was conducted during the development of the eMAR application. Two usability methods were used: a heuristic evaluation complemented by usability testing. Each eMAR application version provided by the vendor was evaluated by 2 hospital pharmacists, who applied the heuristic method. They reviewed the eMAR tasks, detected usability problems and their heuristic violations, and rated the severity of the usability problems. Usability testing was used to assess the final application version by observing how 3 nurses interacted with the application. Thirty-four versions were assessed before the eMAR application was considered usable. During the heuristic evaluation, the usability problems decreased from 46 unique usability problems in version 1 (V1) to 9 in version 34 (V34). In V1, usability problems were categorized into 154 heuristic violations, which decreased to 27 in V34. The average severity rating also decreased from major usability problem (2.96) to no problem (0.23). During usability testing, the 3 nurses did not encounter new usability problems. A thorough heuristic evaluation is a good method for obtaining a usable eMAR application. This evaluation points key areas for improvement and decreases usability problems and their severity. © 2017 John Wiley & Sons, Ltd.

  7. From expert-derived user needs to user-perceived ease of use and usefulness: a two-phase mixed-methods evaluation framework.

    PubMed

    Boland, Mary Regina; Rusanov, Alexander; So, Yat; Lopez-Jimenez, Carlos; Busacca, Linda; Steinman, Richard C; Bakken, Suzanne; Bigger, J Thomas; Weng, Chunhua

    2014-12-01

    Underspecified user needs and frequent lack of a gold standard reference are typical barriers to technology evaluation. To address this problem, this paper presents a two-phase evaluation framework involving usability experts (phase 1) and end-users (phase 2). In phase 1, a cross-system functionality alignment between expert-derived user needs and system functions was performed to inform the choice of "the best available" comparison system to enable a cognitive walkthrough in phase 1 and a comparative effectiveness evaluation in phase 2. During phase 2, five quantitative and qualitative evaluation methods are mixed to assess usability: time-motion analysis, software log, questionnaires - System Usability Scale and the Unified Theory of Acceptance of Use of Technology, think-aloud protocols, and unstructured interviews. Each method contributes data for a unique measure (e.g., time motion analysis contributes task-completion-time; software log contributes action transition frequency). The measures are triangulated to yield complementary insights regarding user-perceived ease-of-use, functionality integration, anxiety during use, and workflow impact. To illustrate its use, we applied this framework in a formative evaluation of a software called Integrated Model for Patient Care and Clinical Trials (IMPACT). We conclude that this mixed-methods evaluation framework enables an integrated assessment of user needs satisfaction and user-perceived usefulness and usability of a novel design. This evaluation framework effectively bridges the gap between co-evolving user needs and technology designs during iterative prototyping and is particularly useful when it is difficult for users to articulate their needs for technology support due to the lack of a baseline. Copyright © 2013 Elsevier Inc. All rights reserved.

  8. Electric Drive Study. Volume 1

    DTIC Science & Technology

    1987-12-21

    CONDITIONER HIGH VOLTAGE DC ICONDITIONER 3 ,300-50 VOLT5), dCONTROL! Figure 5-4. Typical AC Drive System 20 system usable with an induction motor. The...controlling component in an AC drive is the motor power conditioner . This component changes the high voltage DC power to controlled AC power of...selected voltage and frequency which is applied to the drive motors. Since the vehicle gains stored energy as it is accelerated, the motor power conditioner

  9. Soldier-Robot Team Communication: An Investigation of Exogenous Orienting Visual Display Cues and Robot Reporting Preferences

    DTIC Science & Technology

    2018-02-12

    usability preference. Results under the second focus showed that the frequency with which participants expected status updates differed depending upon the...assistance requests for both navigational route and building selection depending on the type of exogenous visual cues displayed? 3) Is there a difference...in response time to visual reports for both navigational route and building selection depending on the type of exogenous visual cues displayed? 4

  10. Microwave characteristics of GaAs MMIC integratable optical detectors

    NASA Technical Reports Server (NTRS)

    Claspy, Paul C.; Hill, Scott M.; Bhasin, Kul B.

    1989-01-01

    Interdigitated photoconductive detectors were fabricated on microwave device structures, making them easily integratable with Monolithic Microwave Integrated Circuits (MMIC). Detector responsivity as high as 2.5 A/W and an external quantum efficiency of 3.81 were measured. Response speed was nearly independent of electrode geometry, and all detectors had usable response at frequencies to 6 GHz. A small signal model of the detectors based on microwave measurements was also developed.

  11. Unsupervised frequency-recognition method of SSVEPs using a filter bank implementation of binary subband CCA.

    PubMed

    Rabiul Islam, Md; Khademul Islam Molla, Md; Nakanishi, Masaki; Tanaka, Toshihisa

    2017-04-01

    Recently developed effective methods for detection commands of steady-state visual evoked potential (SSVEP)-based brain-computer interface (BCI) that need calibration for visual stimuli, which cause more time and fatigue prior to the use, as the number of commands increases. This paper develops a novel unsupervised method based on canonical correlation analysis (CCA) for accurate detection of stimulus frequency. A novel unsupervised technique termed as binary subband CCA (BsCCA) is implemented in a multiband approach to enhance the frequency recognition performance of SSVEP. In BsCCA, two subbands are used and a CCA-based correlation coefficient is computed for the individual subbands. In addition, a reduced set of artificial reference signals is used to calculate CCA for the second subband. The analyzing SSVEP is decomposed into multiple subband and the BsCCA is implemented for each one. Then, the overall recognition score is determined by a weighted sum of the canonical correlation coefficients obtained from each band. A 12-class SSVEP dataset (frequency range: 9.25-14.75 Hz with an interval of 0.5 Hz) for ten healthy subjects are used to evaluate the performance of the proposed method. The results suggest that BsCCA significantly improves the performance of SSVEP-based BCI compared to the state-of-the-art methods. The proposed method is an unsupervised approach with averaged information transfer rate (ITR) of 77.04 bits min -1 across 10 subjects. The maximum individual ITR is 107.55 bits min -1 for 12-class SSVEP dataset, whereas, the ITR of 69.29 and 69.44 bits min -1 are achieved with CCA and NCCA respectively. The statistical test shows that the proposed unsupervised method significantly improves the performance of the SSVEP-based BCI. It can be usable in real world applications.

  12. Physical habitat classification and instream flow modeling to determine habitat availability during low-flow periods, North Fork Shenandoah River, Virginia

    USGS Publications Warehouse

    Krstolic, Jennifer L.; Hayes, Donald C.; Ruhl, Peter M.

    2006-01-01

    Increasing development and increasing water withdrawals for public, industrial, and agricultural water supply threaten to reduce streamflows in the Shenandoah River basin in Virginia. Water managers need more information to balance human water-supply needs with the daily streamflows necessary for maintaining the aquatic ecosystems. To meet the need for comprehensive information on hydrology, water supply, and instream-flow requirements of the Shenandoah River basin, the U.S. Geological Survey and the Northern Shenandoah Valley Regional Commission conducted a cooperative investigation of habitat availability during low-flow periods on the North Fork Shenandoah River. Historic streamflow data and empirical data on physical habitat, river hydraulics, fish community structure, and recreation were used to develop a physical habitat simulation model. Hydraulic measurements were made during low, medium, and high flows in six reaches at a total of 36 transects that included riffles, runs, and pools, and that had a variety of substrates and cover types. Habitat suitability criteria for fish were developed from detailed fish-community sampling and microhabitat observations. Fish were grouped into four guilds of species and life stages with similar habitat requirements. Simulated habitat was considered in the context of seasonal flow regimes to show the availability of flows that sustain suitable habitat during months when precipitation and streamflow are scarce. The North Fork Shenandoah River basin was divided into three management sections for analysis purposes: the upper section, middle section, and lower section. The months of July, August, and September were chosen to represent a low-flow period in the basin with low mean monthly flows, low precipitation, high temperatures, and high water withdrawals. Exceedance flows calculated from the combined data from these three months describe low-flow periods on the North Fork Shenandoah River. Long-term records from three streamflow-gaging stations were used to characterize the flow regime: North Fork Shenandoah River at Cootes Store, Va. (1925-2002), North Fork Shenandoah River at Mount Jackson, Va. (1943-2002), and North Fork Shenandoah River near Strasburg, Va. (1925-2002). The predominant mesohabitat types (14 percent riffle, 67.3 percent run, and 18.7 percent pool) were classified along the entire river (100 miles) to assist in the selection of reaches for hydraulic and fish community data collection. The upper section has predominantly particle substrate, ranging in size from sand to boulders, and the shortest habitat units. The middle section is a transitional section with increased bedrock substrate and habitat unit length. The lower section has predominantly bedrock substrate and the longest habitat units in the river. The model simulations show that weighted usable-habitat area in the upper management section is highest at flows higher than the 25-percent exceedance flow for July, August, and September. During these three months, total weighted usable-habitat area in this section is often less than the simulated maximum weighted usable-habitat area. Habitat area in the middle management section is highest at flows between the 25- and 75-percent exceedance flows for July, August, and September. In the middle section during these months, both the actual weighted usable-habitat area and the simulated maximum weighted usable-habitat area are associated with this flow range. Weighted usable-habitat area in the lower management section is highest at flows lower than the 75-percent exceedance flow for July, August, and September. In the lower section during these three months, some weighted usable-habitat area is available, but the normal range of flows does not include the simulated maximum weighted usable-habitat area. A time-series habitat analysis associated with the historic streamflow, zero water withdrawals, and doubled water withdrawals was completed. During s

  13. Interactivity Centered Usability Evaluation (ICUE) for Course Management Systems

    ERIC Educational Resources Information Center

    Yoon, Sangil

    2010-01-01

    ICUE (Interactivity Centered Usability Evaluation) is an enhanced usability testing protocol created by the researcher. ICUE augments the facilitator's role for usability testing, and offers strategies in developing and presenting usability tasks during a testing session. ICUE was designed to address weaknesses found in the usability evaluation of…

  14. Usability Prediction & Ranking of SDLC Models Using Fuzzy Hierarchical Usability Model

    NASA Astrophysics Data System (ADS)

    Gupta, Deepak; Ahlawat, Anil K.; Sagar, Kalpna

    2017-06-01

    Evaluation of software quality is an important aspect for controlling and managing the software. By such evaluation, improvements in software process can be made. The software quality is significantly dependent on software usability. Many researchers have proposed numbers of usability models. Each model considers a set of usability factors but do not cover all the usability aspects. Practical implementation of these models is still missing, as there is a lack of precise definition of usability. Also, it is very difficult to integrate these models into current software engineering practices. In order to overcome these challenges, this paper aims to define the term `usability' using the proposed hierarchical usability model with its detailed taxonomy. The taxonomy considers generic evaluation criteria for identifying the quality components, which brings together factors, attributes and characteristics defined in various HCI and software models. For the first time, the usability model is also implemented to predict more accurate usability values. The proposed system is named as fuzzy hierarchical usability model that can be easily integrated into the current software engineering practices. In order to validate the work, a dataset of six software development life cycle models is created and employed. These models are ranked according to their predicted usability values. This research also focuses on the detailed comparison of proposed model with the existing usability models.

  15. Reproducibility of Tumor Motion Probability Distribution Function in Stereotactic Body Radiation Therapy of Lung Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang Fan; Medical Physics Graduate Program, Duke University, Durham, North Carolina; Hu Jing

    2012-11-01

    Purpose: To evaluate the reproducibility of tumor motion probability distribution function (PDF) in stereotactic body radiation therapy (SBRT) of lung cancer using cine megavoltage (MV) images. Methods and Materials: Cine MV images of 20 patients acquired during three-dimensional conformal (6-11 beams) SBRT treatments were retrospectively analyzed to extract tumor motion trajectories. For each patient, tumor motion PDFs were generated per fraction (PDF{sub n}) using three selected 'usable' beams. Patients without at least three usable beams were excluded from the study. Fractional PDF reproducibility (R{sub n}) was calculated as the Dice similarity coefficient between PDF{sub n} to a 'ground-truth' PDF (PDF{submore » g}), which was generated using the selected beams of all fractions. The mean of R{sub n}, labeled as R{sub m}, was calculated for each patient and correlated to the patient's mean tumor motion rang (A{sub m}). Change of R{sub m} during the course of SBRT treatments was also evaluated. Intra- and intersubject coefficient of variation (CV) of R{sub m} and A{sub m} were determined. Results: Thirteen patients had at least three usable beams and were analyzed. The mean of R{sub m} was 0.87 (range, 0.84-0.95). The mean of A{sub m} was 3.18 mm (range, 0.46-7.80 mm). R{sub m} was found to decrease as A{sub m} increases following an equation of R{sub m} = 0.17e{sup -0.9Am} + 0.84. R{sub m} also decreased slightly throughout the course of treatments. Intersubject CV of R{sub m} (0.05) was comparable to intrasubject CV of R{sub m} (range, 0.02-0.09); intersubject CV of A{sub m} (0.73) was significantly greater than intrasubject CV of A{sub m} (range, 0.09-0.24). Conclusions: Tumor motion PDF can be determined using cine MV images acquired during the treatments. The reproducibility of lung tumor motion PDF decreased exponentially as the tumor motion range increased and decreased slightly throughout the course of the treatments.« less

  16. 4-GHz counters bring synthesizers up to speed

    NASA Astrophysics Data System (ADS)

    Lee, F.; Miller, R.

    1984-06-01

    The availability of digital IC counters built on GaAs makes direct frequency division in microwave synthesizers possible. Four GHz is the highest clock rate achievable in production designs. These devices have the ability to drive TTL/CMOS logic, and the counter can be connected directly to single-chip frequency synthesizers controllers. A complete microwave sythesizer is formed by two chips and a voltage-controlled oscillator (VCO). The advantages of GaAs are discussed along with flip-flop basics, aspects of device fabrication, and the characteristics of GaAs MESAFETs. Attention is given to a GaAs prescaler usable for direct conversion, four kinds of flip-flops in a divide-by-two mode, and seven-stage binary ripple counters.

  17. Towards a Usability and Error "Safety Net": A Multi-Phased Multi-Method Approach to Ensuring System Usability and Safety.

    PubMed

    Kushniruk, Andre; Senathirajah, Yalini; Borycki, Elizabeth

    2017-01-01

    The usability and safety of health information systems have become major issues in the design and implementation of useful healthcare IT. In this paper we describe a multi-phased multi-method approach to integrating usability engineering methods into system testing to ensure both usability and safety of healthcare IT upon widespread deployment. The approach involves usability testing followed by clinical simulation (conducted in-situ) and "near-live" recording of user interactions with systems. At key stages in this process, usability problems are identified and rectified forming a usability and technology-induced error "safety net" that catches different types of usability and safety problems prior to releasing systems widely in healthcare settings.

  18. Motivation, expectations, and usability of a driven gait orthosis in stroke patients and their therapists.

    PubMed

    Swinnen, Eva; Lefeber, Nina; Willaert, Ward; De Neef, Fallon; Bruyndonckx, Lyn; Spooren, Annemie; Michielsen, Marc; Ramon, Tine; Kerckhofs, Eric

    2017-05-01

    In the development of efficacious driven gait orthoses (DGO), it is an added value to consider patients' and therapists' perspectives concerning robot-assisted gait training (RAGT). A better understanding of these issues may improve the process of care and outcome. This study aimed to examine stroke patients' motivation and expectations of RAGT, and therapists' expectations and perspectives on the usability of RAGT. Additionally, the differences in expectations between stroke patients and their therapists were analyzed. A cross sectional, multi-center, three-group trial was conducted. Included were (1) stroke patients who have experience with RAGT (i.e. the stroke user group), (2) stroke patients who have no experience with RAGT (i.e. the stroke non-user group), and (3) therapists who have experience with RAGT (i.e. the therapist user group). The Intrinsic Motivation Inventory (IMI), Credibility/Expectancy Questionnaire (CEQ), and Usefulness, Satisfaction and Ease of Use Questionnaire (USE) were used. Descriptive statistics and non-parametric Kruskal-Wallis tests were conducted. In total, 46 subjects were assessed (stroke user group: n = 23, stroke non-user group: n = 14, therapist user group: n = 9). IMI subscale scores ranged from 42 to 88%. Mean credibility and expectancy ranged from 80 to 85% and 57 to 72%, respectively, with no significant differences between groups. USE subscale scores ranged from 61 to 72%. Stroke user group patients seem quite motivated to train with the DGO and both patients and therapists reasonably believe that this training could improve gait functioning. Therapists are moderately satisfied with the usability of the DGO, but there is room for improvement with respect to usefulness and ease of use.

  19. Applying human factors principles to alert design increases efficiency and reduces prescribing errors in a scenario-based simulation

    PubMed Central

    Russ, Alissa L; Zillich, Alan J; Melton, Brittany L; Russell, Scott A; Chen, Siying; Spina, Jeffrey R; Weiner, Michael; Johnson, Elizabette G; Daggy, Joanne K; McManus, M Sue; Hawsey, Jason M; Puleo, Anthony G; Doebbeling, Bradley N; Saleem, Jason J

    2014-01-01

    Objective To apply human factors engineering principles to improve alert interface design. We hypothesized that incorporating human factors principles into alerts would improve usability, reduce workload for prescribers, and reduce prescribing errors. Materials and methods We performed a scenario-based simulation study using a counterbalanced, crossover design with 20 Veterans Affairs prescribers to compare original versus redesigned alerts. We redesigned drug–allergy, drug–drug interaction, and drug–disease alerts based upon human factors principles. We assessed usability (learnability of redesign, efficiency, satisfaction, and usability errors), perceived workload, and prescribing errors. Results Although prescribers received no training on the design changes, prescribers were able to resolve redesigned alerts more efficiently (median (IQR): 56 (47) s) compared to the original alerts (85 (71) s; p=0.015). In addition, prescribers rated redesigned alerts significantly higher than original alerts across several dimensions of satisfaction. Redesigned alerts led to a modest but significant reduction in workload (p=0.042) and significantly reduced the number of prescribing errors per prescriber (median (range): 2 (1–5) compared to original alerts: 4 (1–7); p=0.024). Discussion Aspects of the redesigned alerts that likely contributed to better prescribing include design modifications that reduced usability-related errors, providing clinical data closer to the point of decision, and displaying alert text in a tabular format. Displaying alert text in a tabular format may help prescribers extract information quickly and thereby increase responsiveness to alerts. Conclusions This simulation study provides evidence that applying human factors design principles to medication alerts can improve usability and prescribing outcomes. PMID:24668841

  20. Applying human factors principles to alert design increases efficiency and reduces prescribing errors in a scenario-based simulation.

    PubMed

    Russ, Alissa L; Zillich, Alan J; Melton, Brittany L; Russell, Scott A; Chen, Siying; Spina, Jeffrey R; Weiner, Michael; Johnson, Elizabette G; Daggy, Joanne K; McManus, M Sue; Hawsey, Jason M; Puleo, Anthony G; Doebbeling, Bradley N; Saleem, Jason J

    2014-10-01

    To apply human factors engineering principles to improve alert interface design. We hypothesized that incorporating human factors principles into alerts would improve usability, reduce workload for prescribers, and reduce prescribing errors. We performed a scenario-based simulation study using a counterbalanced, crossover design with 20 Veterans Affairs prescribers to compare original versus redesigned alerts. We redesigned drug-allergy, drug-drug interaction, and drug-disease alerts based upon human factors principles. We assessed usability (learnability of redesign, efficiency, satisfaction, and usability errors), perceived workload, and prescribing errors. Although prescribers received no training on the design changes, prescribers were able to resolve redesigned alerts more efficiently (median (IQR): 56 (47) s) compared to the original alerts (85 (71) s; p=0.015). In addition, prescribers rated redesigned alerts significantly higher than original alerts across several dimensions of satisfaction. Redesigned alerts led to a modest but significant reduction in workload (p=0.042) and significantly reduced the number of prescribing errors per prescriber (median (range): 2 (1-5) compared to original alerts: 4 (1-7); p=0.024). Aspects of the redesigned alerts that likely contributed to better prescribing include design modifications that reduced usability-related errors, providing clinical data closer to the point of decision, and displaying alert text in a tabular format. Displaying alert text in a tabular format may help prescribers extract information quickly and thereby increase responsiveness to alerts. This simulation study provides evidence that applying human factors design principles to medication alerts can improve usability and prescribing outcomes. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  1. Mixed methods evaluation of a quality improvement and audit tool for nurse-to-nurse bedside clinical handover in ward settings.

    PubMed

    Redley, Bernice; Waugh, Rachael

    2018-04-01

    Nurse bedside handover quality is influenced by complex interactions related to the content, processes used and the work environment. Audit tools are seldom tested in 'real' settings. Examine the reliability, validity and usability of a quality improvement tool for audit of nurse bedside handover. Naturalistic, descriptive, mixed-methods. Six inpatient wards at a single large not-for-profit private health service in Victoria, Australia. Five nurse experts and 104 nurses involved in 199 change-of-shift bedside handovers. A focus group with experts and pilot test were used to examine content and face validity, and usability of the handover audit tool. The tool was examined for inter-rater reliability and usability using observation audits of handovers across six wards. Data were collected in 2013-2014. Two independent observers for 72 audits demonstrated acceptable inter-observer agreement for 27 (77%) items. Reliability was weak for items examining the handover environment. Seventeen items were not observed reflecting gaps in practices. Across 199 observation audits, gaps in nurse bedside handover practice most often related to process and environment, rather than content items. Usability was impacted by high observer burden, familiarity and non-specific illustrative behaviours. The reliability and validity of most items to audit handover content was acceptable. Gaps in practices for process and environment items were identified. Context specific exemplars and reducing the items used at each handover audit can enhance usability. Further research is needed to develop context specific exemplars and undertake additional reliability testing using a wide range of handover settings. CONTRIBUTION OF THE PAPER. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Development of a Prototype Continuity of Care Record with Context-Specific Links to Meet the Information Needs of Case Managers for Persons Living with HIV

    PubMed Central

    Cimino, James J.; Bakken, Suzanne

    2012-01-01

    Objectives (1) To develop a prototype Continuity of Care Record (CCR) with context-specific links to electronic HIV information resources; and (2) to assess case managers’ perceptions regarding the usability of the prototype. Methods We integrated context-specific links to HIV case management information resources into a prototype CCR using the Infobutton Manager and Librarian Infobutton Tailoring Environment (LITE). Case managers (N=9) completed a think-aloud protocol and the Computer System Usability Questionnaire (CSUQ) to evaluate the usability of the prototype. Verbalizations from the think-aloud protocol were summarized using thematic analysis. CSUQ data were analyzed with descriptive statistics. Results Although participants expressed positive comments regarding the usability of the prototype, the think-aloud protocol also identified the need for improvement in resource labels and for additional resources. On a scale ranging from 1 (strongly agree) to 7 (strongly disagree), the average CSUQ overall satisfaction was 2.25 indicating that users (n=9) were generally satisfied with the system. Mean CSUQ factor scores were: System Usefulness (M=2.13), Information Quality (M=2.46), and Interface Quality (M=2.26). Conclusion Our novel application of the Infobutton Manager and LITE in the context of case management for persons living with HIV in community-based settings resulted in a prototype CCR with infobuttons that met the majority of case managers’ information needs and received relatively positive usability ratings. Findings from this study inform future integration of context-specific links into CCRs and electronic health records and support their use for meeting end-users information needs. PMID:22632821

  3. Development and usability testing of a web-based cancer symptom and quality-of-life support intervention.

    PubMed

    Wolpin, S E; Halpenny, B; Whitman, G; McReynolds, J; Stewart, M; Lober, W B; Berry, D L

    2015-03-01

    The feasibility and acceptability of computerized screening and patient-reported outcome measures have been demonstrated in the literature. However, patient-centered management of health information entails two challenges: gathering and presenting data using "patient-tailored" methods and supporting "patient-control" of health information. The design and development of many symptom and quality-of-life information systems have not included opportunities for systematically collecting and analyzing user input. As part of a larger clinical trial, the Electronic Self-Report Assessment for Cancer-II project, participatory design approaches were used to build and test new features and interfaces for patient/caregiver users. The research questions centered on patient/caregiver preferences with regard to the following: (a) content, (b) user interface needs, (c) patient-oriented summary, and (d) patient-controlled sharing of information with family, caregivers, and clinicians. Mixed methods were used with an emphasis on qualitative approaches; focus groups and individual usability tests were the primary research methods. Focus group data were content analyzed, while individual usability sessions were assessed with both qualitative and quantitative methods. We identified 12 key patient/caregiver preferences through focus groups with 6 participants. We implemented seven of these preferences during the iterative design process. We deferred development for some of the preferences due to resource constraints. During individual usability testing (n = 8), we were able to identify 65 usability issues ranging from minor user confusion to critical errors that blocked task completion. The participatory development model that we used led to features and design revisions that were patient centered. We are currently evaluating new approaches for the application interface and for future research pathways. We encourage other researchers to adopt user-centered design approaches when building patient-centered technologies. © The Author(s) 2014.

  4. From Usability Engineering to Evidence-based Usability in Health IT.

    PubMed

    Marcilly, Romaric; Peute, Linda; Beuscart-Zephir, Marie-Catherine

    2016-01-01

    Usability is a critical factor in the acceptance, safe use, and success of health IT. The User-Centred Design process is widely promoted to improve usability. However, this traditional case by case approach that is rooted in the sound understanding of users' needs is not sufficient to improve technologies' usability and prevent usability-induced use-errors that may harm patients. It should be enriched with empirical evidence. This evidence is on design elements (what are the most valuable design principles, and the worst usability mistakes), and on the usability evaluation methods (which combination of methods is most suitable in which context). To achieve this evidence, several steps must be fulfilled and challenges must be overcome. Some attempts to search evidence for designing elements of health IT and for usability evaluation methods exist and are summarized. A concrete instance of evidence-based usability design principles for medication-related alerting systems is briefly described.

  5. Technology for home dementia care: A prototype locating system put to the test.

    PubMed

    Megges, Herlind; Freiesleben, Silka Dawn; Jankowski, Natalie; Haas, Brigitte; Peters, Oliver

    2017-09-01

    The user experience of persons with dementia and their primary caregivers with locating systems is not firmly established. Eighteen dyads used a prototype locating system during 4 weeks. Primary outcome measures were ratings of usability, and product functions and features. Secondary outcome measures were caregiver burden, perceived self-efficacy, frequency of use, and willingness to purchase the prototype. Changes in scores between baseline (T 1 ) and end of testing period (T 2 ) were compared by performing independent and dependent samples correlations and descriptive statistics. Seventeen dyads made up the final sample. Ratings of usability and product functions and features were fair, but usability ratings were significantly reduced after 4 weeks. Although the prototype was used infrequently by majority of the participants, most caregivers would be willing to purchase the prototype, with men more willing than women. No significant change in technological willingness, caregiver burden, or perceived self-efficacy was found between T 1 and T 2 . Perceived self-efficacy significantly negatively correlated with willingness to purchase the prototype after 4 weeks. Results highlight the importance of including end users in the research and development phase of locating systems to improve the user experience in home dementia care. Necessary indications for further research are carrying out randomized controlled trials with larger, more representative samples and developing innovative software and hardware solutions.

  6. Testing Quick Response (QR) Codes as an Innovation to Improve Feedback Among Geographically-Separated Clerkship Sites.

    PubMed

    Snyder, Matthew J; Nguyen, Dana R; Womack, Jasmyne J; Bunt, Christopher W; Westerfield, Katie L; Bell, Adriane E; Ledford, Christy J W

    2018-03-01

    Collection of feedback regarding medical student clinical experiences for formative or summative purposes remains a challenge across clinical settings. The purpose of this study was to determine whether the use of a quick response (QR) code-linked online feedback form improves the frequency and efficiency of rater feedback. In 2016, we compared paper-based feedback forms, an online feedback form, and a QR code-linked online feedback form at 15 family medicine clerkship sites across the United States. Outcome measures included usability, number of feedback submissions per student, number of unique raters providing feedback, and timeliness of feedback provided to the clerkship director. The feedback method was significantly associated with usability, with QR code scoring the highest, and paper second. Accessing feedback via QR code was associated with the shortest time to prepare feedback. Across four rotations, separate repeated measures analyses of variance showed no effect of feedback system on the number of submissions per student or the number of unique raters. The results of this study demonstrate that preceptors in the family medicine clerkship rate QR code-linked feedback as a high usability platform. Additionally, this platform resulted in faster form completion than paper or online forms. An overarching finding of this study is that feedback forms must be portable and easily accessible. Potential implementation barriers and the social norm for providing feedback in this manner need to be considered.

  7. Perceptions of Smartphone User-Centered Mobile Health Tracking Apps Across Various Chronic Illness Populations: An Integrative Review.

    PubMed

    Birkhoff, Susan D; Smeltzer, Suzanne C

    2017-07-01

    This integrative review presents a synthesis of the current qualitative research addressing the motivating factors, usability, and experiences of mobile health tracking applications (apps) across various chronic disease populations. Integrative review of the literature. Databases used to conduct this integrative review included: PubMed Plus, Cumulative Index of Nursing and Allied Health Literature (CINAHL), Google Scholar, Science Direct, and EBSCO megafile. The following search terms were used in all five databases: smartphone apps, apps, mHealth, eHealth, mobile health apps, health tracking apps, user-centered apps, wireless technology, engagement, qualitative, and usability. The initial literature review yielded 689 results. Once inclusion and exclusion criteria were employed, 11 studies met the criteria set forth for this review. The reviewed studies provided insight into users' perceptions, experiences, and motivations to incorporate smartphone mobile health apps into their daily lives when living with chronic illnesses. This review indicates the growing interest in user-centered mobile health tracking apps, but with little understanding of motivating factors that foster sustained app use. Mobile health tracking apps targeted to users with chronic conditions need to have a high level of usability in order to motivate users to sustain engagement with their mobile health tracking app. User-centered mobile health tracking app technology is being used with increasing frequency to potentially provide individualized support to chronic illness populations. © 2017 Sigma Theta Tau International.

  8. [Benefits and usability of a pharmaceutical record in medical practice. A survey of hospital doctors and pharmacists (MATRIX study)].

    PubMed

    Schuers, M; Timsit, M; Gillibert, A; Fred, A; Griffon, N; Bénichou, J; Darmoni, S J; Staccini, P

    2016-09-01

    To evaluate the impact of the pharmaceutical patient record use in emergency, geriatric and anaesthesia and intensive care departments, an experimentation was launched in 2013 in 55 hospitals. The purpose of the study was to assess the opinions of physicians and pharmacists about the benefits and usability of the patient pharmaceutical record. An e-mailed self-administered questionnaire was sent to all the pharmacists, anaesthesiologists, geriatricians and emergency physicians of the 55 hospitals involved in the patient pharmaceutical record experimentation. The questionnaire assessed the usability of the patient pharmaceutical record using the "System Usability Scale", as well as its use, its benefits and limitations perceived in clinical practice, and overall user satisfaction. Questionnaires were collected from November 2014 to January 2015. Ninety-six questionnaires were collected, from 47 hospitals, representing 86% of the hospitals involved in the experimentation. The patient pharmaceutical record was effectively operational in 36 hospitals. Data from 73 questionnaires filled by physicians and pharmacists with potential experience with the patient pharmaceutical record were used for evaluation. Forty-two respondents were pharmacists (57%) and 31 were physicians (43%), including 13 geriatricians, 11 emergency physicians and 7 anaesthesiologists. Patient pharmaceutical record overall usability score was 62.5 out of 100. It did not vary with the profession or seniority of the respondent. It was positively correlated with the frequency of use. More than half of respondents reported that they never or uncommonly used the patient pharmaceutical record. The length of access to data period was considered as insufficient. Main obstacles to more utilization of the patient pharmaceutical record were the lack of information about the dosage of dispensed drugs, the low number of patients in possession of their health card and the low number of patients with an activated patient pharmaceutical record. Two years after the beginning of the experiment aiming to broaden the access to the patient pharmaceutical record to physicians, these first evaluation results are encouraging. The evaluation of the consequences of the access to the patient pharmaceutical record for physicians remains necessary. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  9. Measuring AT Usability with the Modified System Usability Scale (SUS).

    PubMed

    Friesen, Emma L

    2017-01-01

    The modified System Usability Scale (SUS) is a widely used generic measure of product usability. This study concerns the usability of mobile shower commodes using correlations between the SUS and AT device-specific measures. Results suggest the modified SUS, and corresponding adjective-anchored rating scale, are appropriate for measuring MSC usability, and have potential for use with other AT devices.

  10. Press-On Optics

    ERIC Educational Resources Information Center

    Thorson, Jon C.

    1972-01-01

    The article discusses the design, application, and clinical uses of press-on optics which are descirbed as 1 millimeter thick, flexible lenses or prisms that may be produced in virtually any desired plus or minus dioptric power as ophthalmic lenses, or in any range of usable prism diopter power. (GW)

  11. Usability Evaluation of a Web-Based Symptom Monitoring Application for Heart Failure.

    PubMed

    Wakefield, Bonnie; Pham, Kassie; Scherubel, Melody

    2015-07-01

    Symptom recognition and reporting by patients with heart failure are critical to avoid hospitalization. This project evaluated a patient symptom tracking application. Fourteen end users (nine patients, five clinicians) from a Midwestern Veterans Affairs Medical Center evaluated the website using a think aloud protocol. A structured observation protocol was used to assess success or failure for each task. Measures included task time, success, and satisfaction. Patients had a mean age of 70 years; clinicians averaged 42 years in age. Patients took 9.3 min and clinicians took less than 3 min per scenario. Most patients needed some assistance, but few patients were completely unable to complete some tasks. Clinicians demonstrated few problems navigating the site. Patient System Usability Scale item scores ranged from 2.0 to 3.6; clinician item scores ranged from 1.8 to 4.0. Further work is needed to determine whether using the web-based tool improves symptom recognition and reporting. © The Author(s) 2015.

  12. Barriers to comparing the usability of electronic health records.

    PubMed

    Ratwani, Raj M; Hettinger, A Zachary; Fairbanks, Rollin J

    2017-04-01

    Despite the widespread adoption of electronic health records (EHRs), usability of many EHRs continues to be suboptimal, with some vendors failing to meet usability standards, resulting in clinician frustration and patient safety hazards. In an effort to increase EHR vendor competition on usability, recommendations have been made and legislation drafted to develop comparison tools that would allow purchasers to better understand the usability of EHR products prior to purchase. Usability comparison can be based on EHR vendor design and development processes, vendor usability testing as part of the Office of the National Coordinator for Health Information Technology certification program, and usability of implemented products. Barriers exist within the current certified health technology program that prevent effective comparison of usability during each of these stages. We describe the importance of providing purchasers with improved information about EHR usability, barriers to making usability comparisons, and solutions to overcome these barriers. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. In-situ Calibration Methods for Phased Array High Frequency Radars

    NASA Astrophysics Data System (ADS)

    Flament, P. J.; Flament, M.; Chavanne, C.; Flores-vidal, X.; Rodriguez, I.; Marié, L.; Hilmer, T.

    2016-12-01

    HF radars measure currents through the Doppler-shift of electromagnetic waves Bragg-scattered by surface gravity waves. While modern clocks and digital synthesizers yield range errors negligible compared to the bandwidth-limited range resolution, azimuth calibration issues arise for beam-forming phased arrays. Sources of errors in the phases of the received waves can be internal to the radar system (phase errors of filters, cable lengths, antenna tuning) and geophysical (standing waves, propagation and refraction anomalies). They result in azimuthal biases (which can be range-dependent) and beam-forming side-lobes (which induce Doppler ambiguities). We analyze the experimental calibrations of 17 deployments of WERA HF radars, performed between 2003 and 2012 in Hawaii, the Adriatic, France, Mexico and the Philippines. Several strategies were attempted: (i) passive reception of continuous multi-frequency transmitters on GPS-tracked boats, cars, and drones; (ii) bi-static calibrations of radars in mutual view; (iii) active echoes from vessels of opportunity of unknown positions or tracked through AIS; (iv) interference of unknown remote transmitters with the chirped local oscillator. We found that: (a) for antennas deployed on the sea shore, a single-azimuth calibration is sufficient to correct phases within a typical beam-forming azimuth range; (b) after applying this azimuth-independent correction, residual pointing errors are 1-2 deg. rms; (c) for antennas deployed on irregular cliffs or hills, back from shore, systematic biases appear for some azimuths at large incidence angles, suggesting that some of the ground-wave electromagnetic energy propagates in a terrain-following mode between the sea shore and the antennas; (d) for some sites, fluctuations of 10-25 deg. in radio phase at 20-40 deg. azimuthal period, not significantly correlated among antennas, are omnipresent in calibrations along a constant-range circle, suggesting standing waves or multiple paths in the presence of reflecting structures (buildings, fences), or possibly fractal nature of the wavefronts; (e) amplitudes lack stability in time and azimuth to be usable as a-priori calibrations, confirming the accepted method of re-normalizing amplitudes by the signal of nearby cells prior to beam-forming.

  14. 36 CFR 1193.39 - Prohibited reduction of accessibility, usability, and compatibility.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... accessibility, usability, and compatibility. 1193.39 Section 1193.39 Parks, Forests, and Public Property... Requirements for Accessibility and Usability § 1193.39 Prohibited reduction of accessibility, usability, and... accessibility, usability, or compatibility of telecommunications equipment or customer premises equipment. (b...

  15. 36 CFR 1193.39 - Prohibited reduction of accessibility, usability, and compatibility.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... accessibility, usability, and compatibility. 1193.39 Section 1193.39 Parks, Forests, and Public Property... Requirements for Accessibility and Usability § 1193.39 Prohibited reduction of accessibility, usability, and... accessibility, usability, or compatibility of telecommunications equipment or customer premises equipment. (b...

  16. 36 CFR 1193.39 - Prohibited reduction of accessibility, usability, and compatibility.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... accessibility, usability, and compatibility. 1193.39 Section 1193.39 Parks, Forests, and Public Property... Requirements for Accessibility and Usability § 1193.39 Prohibited reduction of accessibility, usability, and... accessibility, usability, or compatibility of telecommunications equipment or customer premises equipment. (b...

  17. 36 CFR 1193.39 - Prohibited reduction of accessibility, usability, and compatibility.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... accessibility, usability, and compatibility. 1193.39 Section 1193.39 Parks, Forests, and Public Property... Requirements for Accessibility and Usability § 1193.39 Prohibited reduction of accessibility, usability, and... accessibility, usability, or compatibility of telecommunications equipment or customer premises equipment. (b...

  18. Usability of patient-centered health IT: mixed-methods usability study of ePill.

    PubMed

    Schmidt-Kraepelin, Manuel; Dehling, Tobias; Sunyaev, Ali

    2014-01-01

    To facilitate use of patient-centered health IT applications in everyday life, a high degree of usability is required. Based on the example of a patient-centered web application, we propose a usability study design enabling developers and researchers to assess usability of patient-centered health IT applications and derive implications for their improvement. Our study design integrates tasks that subjects have to process, an associated questionnaire based on Perceived Ease of Use, Perceived Usefulness, Attitude Toward Using, and Behavioral Intention to Use, a System Usability Scale questionnaire, and focus groups. Application of the usability study design demonstrates its feasibility and provides insights for assessment of usability in related projects in research and practice.

  19. A Survey of Usability Practices in Free/Libre/Open Source Software

    NASA Astrophysics Data System (ADS)

    Paul, Celeste Lyn

    A review of case studies about usability in eight Free/Libre/Open Source Software (FLOSS) projects showed that an important issue regarding a usability initiative in the project was the lack of user research. User research is a key component in the user-centered design (UCD) process and a necessary step for creating usable products. Reasons why FLOSS projects suffered from a lack of user research included poor or unclear project leadership, cultural differences between developer and designers, and a lack of usability engineers. By identifying these critical issues, the FLOSS usability community can begin addressing problems in the efficacy of usability activities and work towards creating more usable FLOSS products.

  20. Second Version of Google Glass as a Wearable Socio-Affective Aid: Positive School Desirability, High Usability, and Theoretical Framework in a Sample of Children with Autism.

    PubMed

    Sahin, Ned T; Keshav, Neha U; Salisbury, Joseph P; Vahabzadeh, Arshya

    2018-01-04

    Computerized smartglasses are being developed as an assistive technology for daily activities in children and adults with autism spectrum disorder (ASD). While smartglasses may be able to help with educational and behavioral needs, their usability and acceptability in children with ASD is largely unknown. There have been reports of negative social perceptions surrounding smartglasses use in mainstream populations, a concern given that assistive technologies may already carry their own stigma. Children with ASD may also have a range of additional behavioral, developmental, and social challenges when asked to use this emerging technology in school and home settings. The usability and acceptability of Glass Enterprise Edition (Glass), the successor to Google Glass smartglasses, were explored in children with ASD and their caregivers. Eight children with ASD and their caregivers were recruited to attend a demonstration session with Glass smartglasses the week they were publicly released. The children had a wide range of ability, including limited speech to speaking, and represented a full range of school ages (6 to 17 years). Children and caregivers were interviewed about their experience of using the smartglasses and whether they would use them at school and home. All 8 children succeeded in using Glass and did not feel stressed (8/8, 100%) or experience any overwhelming sensory or emotional issues during the session (8/8, 100%). All 8 children (8/8, 100%) endorsed that they would be willing to wear and use the device in both home and school settings. Caregivers felt the experience was fun for the children (8/8, 100%), and most caregivers felt the experience was better than they had expected (6/8, 75%). A wide age and ability range of children with ASD used Glass immediately after it was released and found it to be usable and acceptable. Despite concerns about potential stigma or social acceptability, all of the children were prepared to use the technology in both home and school settings. Encouragingly, most caregivers noted a very positive response. There were no behavioral, developmental, or social- or stigma-related concerns during or after the session. Smartglasses may be a useful future technology for children with ASD and are readily accepted for use by children with ASD and their caregivers. ©Ned T Sahin, Neha U Keshav, Joseph P Salisbury, Arshya Vahabzadeh. Originally published in JMIR Human Factors (http://humanfactors.jmir.org), 04.01.2018.

  1. How Do We Teach Usability? An Investigation of Usability Instruction in Technical Communication

    ERIC Educational Resources Information Center

    Chong, Felicia

    2013-01-01

    This dissertation investigates the curricular implementation of usability instruction in technical communication. Though there are a plethora of publications and studies on usability in technical communication, little discussion focuses on usability instruction in the classroom or its implementation in the curriculum. Thus, this exploratory…

  2. Early-Stage Software Design for Usability

    ERIC Educational Resources Information Center

    Golden, Elspeth

    2010-01-01

    In spite of the goodwill and best efforts of software engineers and usability professionals, systems continue to be built and released with glaring usability flaws that are costly and difficult to fix after the system has been built. Although user interface (UI) designers, be they usability or design experts, communicate usability requirements to…

  3. 36 CFR § 1193.39 - Prohibited reduction of accessibility, usability, and compatibility.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... accessibility, usability, and compatibility. § 1193.39 Section § 1193.39 Parks, Forests, and Public Property... Requirements for Accessibility and Usability § 1193.39 Prohibited reduction of accessibility, usability, and... accessibility, usability, or compatibility of telecommunications equipment or customer premises equipment. (b...

  4. Increasing EHR system usability through standards: Conformance criteria in the HL7 EHR-system functional model.

    PubMed

    Meehan, Rebecca A; Mon, Donald T; Kelly, Kandace M; Rocca, Mitra; Dickinson, Gary; Ritter, John; Johnson, Constance M

    2016-10-01

    Though substantial work has been done on the usability of health information technology, improvements in electronic health record system (EHR) usability have been slow, creating frustration, distrust of EHRs and the use of potentially unsafe work-arounds. Usability standards could be part of the solution for improving EHR usability. EHR system functional requirements and standards have been used successfully in the past to specify system behavior, the criteria of which have been gradually implemented in EHR systems through certification programs and other national health IT strategies. Similarly, functional requirements and standards for usability can help address the multitude of sequelae associated with poor usability. This paper describes the evidence-based functional requirements for usability contained in the Health Level Seven (HL7) EHR System Functional Model, and the benefits of open and voluntary EHR system usability standards. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Usability in Mobile Electronic Data Collection Tools: Form Developers' Views.

    PubMed

    Mugisha, Alice; Babic, Ankica; Wakholi, Peter; Nankabirwa, Victoria; Tylleskar, Thorkild

    2017-01-01

    Mobile Electronic Data Collection Tools (MEDCTs) are created by form developers to collect data. Usability being one of the top quality attributes is of great concern to developers of any interactive applications. However, little is known about the form developers' understanding of usability, how they measure usability and their limitations in designing for usability. We conducted an empirical study where we aimed at getting the developers' views on usability by interviewing 8 form developers. These are creators of forms used for data collection. We found that developers knew about usability, but it was not their main focus during form development. Challenges included constraining deadlines, software limitations and the insufficient communication with the field users to establish the usability needs. Furthermore, the methods used to evaluate the usability of created forms varied amongst developers and these included in-house evaluations and feedback from piloting sessions with end users.

  6. Simultaneous estimation of arterial and venous oxygen saturation using a camera

    NASA Astrophysics Data System (ADS)

    van Gastel, Mark; Liang, Hangbing; Stuijk, Sander; de Haan, Gerard

    2018-02-01

    Optical monitoring of arterial blood oxygenation, SpO2, using cameras has recently been shown feasible by measuring the relative amplitudes of the remotely sensed PPG waveforms captured at different wavelengths. SvO2 measures the venous blood oxygenation which together with SpO2 provides an indication of tissue oxygen consumption. In contrast to SpO2 it usually still requires a blood sample from a pulmonary artery catheter. In this work we present a method which suggests simultaneous estimation of SpO2 and SvO2 with a camera. Contrary to earlier work, our method does not require external cuffs leading to better usability and improved comfort. Since the arterial blood varies synchronously with the heart rate, all frequencies outside the heart rate band are typically filtered out for SpO2 measurements. For SvO2 estimation, we include intensity variations in the respiratory frequency range since respiration modulates venous blood due to intrathoracic pressure variations in the chest and abdomen. Consequently, under static conditions, the two dominant components in the PPG signals are respiration and pulse. By measuring the amplitude ratios of these components, it seems possible to monitor both SpO2 and SvO2 continuously. We asked healthy subjects to follow an auditory breathing pattern while recording the face and hand. Results show a difference in estimated SpO2 and SvO2 values in the range 5-30 percent for both anatomical locations, which is normal for healthy people. This continuous, non-contact, method shows promise to alert the clinician to a change in patient condition sooner than SpO2 alone.

  7. Geosynchronous platform definition study. Volume 3: Geosynchronous mission characteristics

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The objectives of the study were to examine the nature of currently planned and new evolutionary geosynchronous programs, to analyze alternative ways of conducting missions, to establish concepts for new systems to support geosynchronous programs in an effective and economical manner, and to define the logistic support to carry out these programs. In order to meet these objectives, it was necessary to define and examine general geosynchronous mission characteristics and the potentially applicable electromagnetic spectrum characteristics. An organized compilation of these data is given with emphasis on the development and use of the data. Fundamental geosynchronous orbit time histories, mission profile characteristics, and delivery system characteristics are presented. In addition, electromagnetic spectrum utilization is discussed in terms of the usable frequency spectrum, the spectrum potentially available considering established frequency allocations, and the technology status as it affects the ability to operate within specific frequency bands.

  8. Modeling of Army Research Laboratory EMP simulators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miletta, J.R.; Chase, R.J.; Luu, B.B.

    1993-12-01

    Models are required that permit the estimation of emitted field signatures from EMP simulators to design the simulator antenna structure, to establish the usable test volumes, and to estimate human exposure risk. This paper presents the capabilities and limitations of a variety of EMP simulator models useful to the Army's EMP survivability programs. Comparisons among frequency and time-domain models are provided for two powerful US Army Research Laboratory EMP simulators: AESOP (Army EMP Simulator Operations) and VEMPS II (Vertical EMP Simulator II).

  9. Enhancing Access to Patient Education Information: A Pilot Usability Study

    PubMed Central

    Beaudoin, Denise E.; Rocha, Roberto A.; Tse, Tony

    2005-01-01

    Health care organizations are developing Web-based portals to provide patient access to personal health information and enhance patient-provider communication. This pilot study investigates two navigation models (“serial” and “menu-driven”) for improving access to education materials available through a portal. There was a trend toward greater user satisfaction with the menu-driven model. Model preference was influenced by frequency of Web use. Results should aid in the improvement of existing portals and in the development of new ones. PMID:16779179

  10. Cuttlefish Sepia officinalis Preferentially Respond to Bottom Rather than Side Stimuli When Not Allowed Adjacent to Tank Walls

    DTIC Science & Technology

    2015-10-14

    especially because cuttlefish are colorblind. Another possible concern is the flicker frequency of the plasma screens. The plasma screens used in... flicker . Given these reasons, we believe that the most reliable behavior with the least amount of human disturbance resulted from our use of the...0138690 October 14, 2015 15 / 18 Image analysis To mitigate the likelihood of autocorrelation, we used the two usable (i.e., non-blurry) images that were

  11. Method of Lines Transpose an Implicit Vlasov Maxwell Solver for Plasmas

    DTIC Science & Technology

    2015-04-17

    boundary crossings should be rare. Numerical results for the Bennett pinch are given in Figure 9. In order to resolve large gradients near the center of the...contributing to the large error at the center of the beam due to large gradients there) and with the finite beam cut-off radius and the outflow boundary...usable time step size can be limited by the numerical accuracy of the method when there are large gradients (high-frequency content) in the solution. We

  12. Perceived Usability Evaluation of Learning Management Systems: Empirical Evaluation of the System Usability Scale

    ERIC Educational Resources Information Center

    Orfanou, Konstantina; Tselios, Nikolaos; Katsanos, Christos

    2015-01-01

    Perceived usability affects greatly student's learning effectiveness and overall learning experience, and thus is an important requirement of educational software. The System Usability Scale (SUS) is a well-researched and widely used questionnaire for perceived usability evaluation. However, surprisingly few studies have used SUS to evaluate the…

  13. Cryogenic Amplifier Based Receivers at Submillimeter Wavelengths

    NASA Technical Reports Server (NTRS)

    Chattopadhyay, Goutam; Reck, Theodore and; Schlecht, Erich; Lin, Robert; Deal, William

    2012-01-01

    The operating frequency of InP high electron mobility transistor (HEMT) based amplifiers has moved well in the submillimeter-wave frequencies over the last couple of years. Working amplifiers with usable gain in waveguide packages has been reported beyond 700 GHz. When cooled cryogenically, they have shown substantial improvement in their noise temperature. This has opened up the real possibility of cryogenic amplifier based heterodyne receivers at submillimeter wavelengths for ground-based, air-borne, and space-based instruments for astrophysics, planetary, and Earth science applications. This paper provides an overview of the science applications at submillimeter wavelengths that will benefit from this technology. It also describes the current state of the InP HEMT based cryogenic amplifier receivers at submillimeter wavelengths.

  14. Radiofrequency testing of satellite segment of simulated 30/20 GHz satellite communications system

    NASA Technical Reports Server (NTRS)

    Leonard, R. F.; Kerczewski, R.

    1985-01-01

    A laboratory communications system has been developed that can serve as a test bed for the evaluation of advanced microwave (30/20 GHz) components produced under NASA technology programs. The system will ultimately permit the transmission of a stream of high-rate (220 Mbps) digital data from the originating user, through a ground terminal, through a hardware-simulated satellite, to a receiving ground station, to the receiving user. This report contains the results of radiofrequency testing of the satellite portion of that system. Data presented include output spurious responses, attainable signal-to-noise ratios, a baseline power budget, usable frequency bands, phase and amplitude response data for each of the frequency bands, and the effects of power level variation.

  15. High temperature glass coatings for superalloys and refractory metals

    NASA Technical Reports Server (NTRS)

    Chapman, J. W.; Grekila, R. B.; Hirayama, C.; Mattox, D. M.

    1970-01-01

    New glasses are used as protective coatings on metals and alloys susceptible to oxidation at high temperatures in oxidizing atmospheres. Glasses are stable and solid at temperatures up to 1000 deg C, adhere well to metal surfaces, and are usable for metals with broad range of expansion coefficients.

  16. Exploring the Usability of Mobile Apps Supporting Radiologists' Training in Diagnostic Decision Making.

    PubMed

    Kim, Min Soon; Aro, Michael R; Lage, Kraig J; Ingalls, Kevin L; Sindhwani, Vivek; Markey, Mia K

    2016-03-01

    The objective of this study was to conduct a usability evaluation of mobile apps for supporting education and training in radiologic diagnostic decision-making processes. Of 381 mobile apps available at two major stores (Google Play and iTunes), eight iOS apps were selected for laboratory-based usability tests. Six staff radiologists completed eight app-specific task sets, using a think-aloud strategy. The triangular methods approach included quantitative performance measures, System Usability Scale (SUS), and qualitative thematic analysis using heuristic usability principles of usability issues. Overall, radiologists achieved higher than 70% success, with favorable SUS scores, in completing the tasks for seven of the eight apps. However, task success rate and SUS score had a weak relation (r = 0.23), indicating that the perceived usability may not reflect the holistic usability of the app. Task analysis and self-report revealed 108 usability issues, which were condensed to 55 unique issues and categorized by nine usability themes and mapped to ten usability heuristics. Nonintuitive functionality (eg, nonintuitive or misleading labels) was the most frequent theme observed, leading to inefficient navigation. These usability findings were consistent with the 13 improvements the radiologists suggested. This study demonstrates the feasibility of usability evaluation of radiology mobile apps and suggests potential improvements in the development of radiology mobile apps. This study also suggests that proficiency with mobile devices may not be equivalent to being an expert user, proficient in using the apps. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  17. Usability flaws of medication-related alerting functions: A systematic qualitative review.

    PubMed

    Marcilly, Romaric; Ammenwerth, Elske; Vasseur, Francis; Roehrer, Erin; Beuscart-Zéphir, Marie-Catherine

    2015-06-01

    Medication-related alerting functions may include usability flaws that limit their optimal use. A first step on the way to preventing usability flaws is to understand the characteristics of these usability flaws. This systematic qualitative review aims to analyze the type of usability flaws found in medication-related alerting functions. Papers were searched via PubMed, Scopus and Ergonomics Abstracts databases, along with references lists. Paper selection, data extraction and data analysis was performed by two to three Human Factors experts. Meaningful semantic units representing instances of usability flaws were the main data extracted. They were analyzed through qualitative methods: categorization following general usability heuristics and through an inductive process for the flaws specific to medication-related alerting functions. From the 6380 papers initially identified, 26 met all eligibility criteria. The analysis of the papers identified a total of 168 instances of usability flaws that could be classified into 13 categories of usability flaws representing either violations of general usability principles (i.e. they could be found in any system, e.g. guidance and workload issues) or infractions specific to medication-related alerting functions. The latter refer to issues of low signal-to-noise ratio, incomplete content of alerts, transparency, presentation mode and timing, missing alert features, tasks and control distribution. The list of 168 instances of usability flaws of medication-related alerting functions provides a source of knowledge for checking the usability of medication-related alerting functions during their design and evaluation process and ultimately constructs evidence-based usability design principles for these functions. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. 14 CFR Appendix B to Part 135 - Airplane Flight Recorder Specifications

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... altitude resolution) −20° to 40° or of usable range ±2° 1 0.8% 3 Radio transmitter keying (discrete) On/off 1 TE flaps (discrete or analog) Each discrete position (U, D, T/O, AAP) 1 Or Analog 0-100% range ±3° 1 1% 3 LE flaps (discrete or analog) Each discrete position (U, D, T/O, AAP) 1 Or Analog 0-100...

  19. 14 CFR Appendix E to Part 91 - Airplane Flight Recorder Specifications

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... altitude resolution) −20° to 40° or 100% of usable range ±2° 1 0.8%3 Radio Transmitter Keying (Discrete) On/Off 1 TE Flaps (Discrete or Analog) Each discrete position (U, D, T/O, AAP) OR 1 LE Flaps (Discrete or Analog) Analog 0-100% range ±3% 1 1%3 Each discrete position (U, D, T/O, AAP) OR 1 Thrust Reverser, Each...

  20. Formative usability evaluation of a fixed-dose pen-injector platform device

    PubMed Central

    Lange, Jakob; Nemeth, Tobias

    2018-01-01

    Background This article for the first time presents a formative usability study of a fixed-dose pen injector platform device used for the subcutaneous delivery of biopharmaceuticals, primarily for self-administration by the patient. The study was conducted with a user population of both naïve and experienced users across a range of ages. The goals of the study were to evaluate whether users could use the devices safely and effectively relying on the instructions for use (IFU) for guidance, as well as to benchmark the device against another similar injector established in the market. Further objectives were to capture any usability issues and obtain participants’ subjective ratings on the properties and performance of both devices. Methods A total of 20 participants in three groups studied the IFU and performed simulated injections into an injection pad. Results All participants were able to use the device successfully. The device was well appreciated by all users with, maximum usability feedback scores reported by 90% or more on handling forces and device feedback, and by 85% or more on fit and grip of the device. The presence of clear audible and visible feedbacks upon successful loading of a dose and completion of injection was seen to be a significant improvement over the benchmark injector. Conclusion The observation that the platform device can be safely and efficiently used by all user groups provides confidence that the device and IFU in their current form will pass future summative testing in specific applications. PMID:29670411

  1. Usability Flaws in Medication Alerting Systems: Impact on Usage and Work System.

    PubMed

    Marcilly, R; Ammenwerth, E; Roehrer, E; Pelayo, S; Vasseur, F; Beuscart-Zéphir, M-C

    2015-08-13

    Previous research has shown that medication alerting systems face usability issues. There has been no previous attempt to systematically explore the consequences of usability flaws in such systems on users (i.e. usage problems) and work systems (i.e. negative outcomes). This paper aims at exploring and synthesizing the consequences of usability flaws in terms of usage problems and negative outcomes on the work system. A secondary analysis of 26 papers included in a prior systematic review of the usability flaws in medication alerting was performed. Usage problems and negative outcomes were extracted and sorted. Links between usability flaws, usage problems, and negative outcomes were also analyzed. Poor usability generates a large variety of consequences. It impacts the user from a cognitive, behavioral, emotional, and attitudinal perspective. Ultimately, usability flaws have negative consequences on the workflow, the effectiveness of the technology, the medication management process, and, more importantly, patient safety. Only few complete pathways leading from usability flaws to negative outcomes were identified. Usability flaws in medication alerting systems impede users, and ultimately their work system, and negatively impact patient safety. Therefore, the usability dimension may act as a hidden explanatory variable that could explain, at least partly, the (absence of) intended outcomes of new technology.

  2. Usability Flaws in Medication Alerting Systems: Impact on Usage and Work System

    PubMed Central

    Ammenwerth, E.; Roehrer, E.; Pelayo, S.; Vasseur, F.; Beuscart-Zéphir, M.-C.

    2015-01-01

    Summary Objectives Previous research has shown that medication alerting systems face usability issues. There has been no previous attempt to systematically explore the consequences of usability flaws in such systems on users (i.e. usage problems) and work systems (i.e. negative outcomes). This paper aims at exploring and synthesizing the consequences of usability flaws in terms of usage problems and negative outcomes on the work system. Methods A secondary analysis of 26 papers included in a prior systematic review of the usability flaws in medication alerting was performed. Usage problems and negative outcomes were extracted and sorted. Links between usability flaws, usage problems, and negative outcomes were also analyzed. Results Poor usability generates a large variety of consequences. It impacts the user from a cognitive, behavioral, emotional, and attitudinal perspective. Ultimately, usability flaws have negative consequences on the workflow, the effectiveness of the technology, the medication management process, and, more importantly, patient safety. Only few complete pathways leading from usability flaws to negative outcomes were identified. Conclusion Usability flaws in medication alerting systems impede users, and ultimately their work system, and negatively impact patient safety. Therefore, the usability dimension may act as a hidden explanatory variable that could explain, at least partly, the (absence of) intended outcomes of new technology. PMID:26123906

  3. Comparison of RF spectrum prediction methods for dynamic spectrum access

    NASA Astrophysics Data System (ADS)

    Kovarskiy, Jacob A.; Martone, Anthony F.; Gallagher, Kyle A.; Sherbondy, Kelly D.; Narayanan, Ram M.

    2017-05-01

    Dynamic spectrum access (DSA) refers to the adaptive utilization of today's busy electromagnetic spectrum. Cognitive radio/radar technologies require DSA to intelligently transmit and receive information in changing environments. Predicting radio frequency (RF) activity reduces sensing time and energy consumption for identifying usable spectrum. Typical spectrum prediction methods involve modeling spectral statistics with Hidden Markov Models (HMM) or various neural network structures. HMMs describe the time-varying state probabilities of Markov processes as a dynamic Bayesian network. Neural Networks model biological brain neuron connections to perform a wide range of complex and often non-linear computations. This work compares HMM, Multilayer Perceptron (MLP), and Recurrent Neural Network (RNN) algorithms and their ability to perform RF channel state prediction. Monte Carlo simulations on both measured and simulated spectrum data evaluate the performance of these algorithms. Generalizing spectrum occupancy as an alternating renewal process allows Poisson random variables to generate simulated data while energy detection determines the occupancy state of measured RF spectrum data for testing. The results suggest that neural networks achieve better prediction accuracy and prove more adaptable to changing spectral statistics than HMMs given sufficient training data.

  4. Improving Public Relations Web Sites through Usability Research.

    ERIC Educational Resources Information Center

    Hallahan, Kirk

    2001-01-01

    Argues that usability research has particular relevance for enhancing the effectiveness of websites. Examines the nature and value of usability research, and the elements of an effective website based on usability principles. (SR)

  5. Applying usability methods to identify health literacy issues: an example using a Personal Health Record.

    PubMed

    Monkman, Helen; Kushniruk, Andre

    2013-01-01

    The prevalence of consumer health information systems is increasing. However, usability and health literacy impact both the value and adoption of these systems. Health literacy and usability are closely related in that systems may not be used accurately if users cannot understand the information therein. Thus, it is imperative to focus on mitigating the demands on health literacy in consumer health information systems. This study modified two usability evaluation methods (heuristic evaluation and usability testing) to incorporate the identification of potential health literacy issues in a Personal Health Record (PHR). Heuristic evaluation is an analysis of a system performed by a usability specialist who evaluates how well the system abides by usability principles. In contrast, a usability test involves a post hoc analysis of a representative user interacting with the system. These two methods revealed several health literacy issues and suggestions to ameliorate them were made. Thus, it was demonstrated that usability methods could be successfully augmented for the purpose of investigating health literacy issues. To improve users' health knowledge, the adoption of consumer health information systems, and the accuracy of the information contained therein, it is encouraged that usability methods be applied with an added focus on health literacy.

  6. Usability evaluation techniques in mobile commerce applications: A systematic review

    NASA Astrophysics Data System (ADS)

    Hussain, Azham; Mkpojiogu, Emmanuel O. C.

    2016-08-01

    Obviously, there are a number of literatures concerning the usability of mobile commerce (m-commerce) applications and related areas, but they do not adequately provide knowledge about usability techniques used in most of the empirical usability evaluation for m-commerce application. Therefore, this paper is aimed at producing the usability techniques frequently used in the aspect of usability evaluation for m-commerce applications. To achieve the stated objective, systematic literature review was employed. Sixty seven papers were downloaded in usability evaluation for m-commerce and related areas; twenty one most relevant studies were selected for review in order to extract the appropriate information. The results from the review shows that heuristic evaluation, formal test and think aloud methods are the most commonly used methods in m-commerce application in comparison to cognitive walkthrough and the informal test methods. Moreover, most of the studies applied control experiment (33.3% of the total studies); other studies that applied case study for usability evaluation are 14.28%. The results from this paper provide additional knowledge to the usability practitioners and research community for the current state and use of usability techniques in m-commerce application.

  7. The current status of usability studies of information technologies in China: a systematic study.

    PubMed

    Lei, Jianbo; Xu, Lufei; Meng, Qun; Zhang, Jiajie; Gong, Yang

    2014-01-01

    To systematically review and analyze the current status and characteristics of usability studies in China in the field of information technology in general and in the field of healthcare in particular. We performed a quantitative literature analysis in three major Chinese academic databases and one English language database using Chinese search terms equivalent to the concept of usability. Six hundred forty-seven publications were selected for analysis. We found that in China the literature on usability in the field of information technology began in 1994 and increased thereafter. The usability definitions from ISO 9241-11:1998 and Nielsen (1993) have been widely recognized and cited. Authors who have published several publications are rare. Fourteen journals have a publishing rate over 1%. Only nine publications about HIT were identified. China's usability research started relatively late. There is a lack of organized research teams and dedicated usability journals. High-impact theoretical studies are scarce. On the application side, no original and systematic research frameworks have been developed. The understanding and definition of usability is not well synchronized with international norms. Besides, usability research in HIT is rare. More human and material resources need to be invested in China's usability research, particularly in HIT.

  8. Usability testing for the rest of us: the application of discount usability principles in the development of an online communications assessment application.

    PubMed

    Brock, Douglas; Kim, Sara; Palmer, Odawni; Gallagher, Thomas; Holmboe, Eric

    2013-01-01

    Usability evaluation provides developers and educators with the means to understand user needs, improve overall product utility, and increase user satisfaction. The application of "discount usability" principles developed to make usability testing more practical and useful may improve user experience at minimal cost and require little existing expertise to conduct. We describe an application of discount usability to a high-fidelity online communications assessment application developed by the University of Washington for the American Board of Internal Medicine. Eight internal medicine physicians completed a discount usability test. Sessions were recorded and the videos analyzed for significant usability concerns. Concerns were identified, summarized, discussed, and prioritized by the authors in collaboration with the software developers before implementing any changes to the interface. Thirty-eight significant usability issues were detected and four technical problems were identified. Each issue was responded to through modification of the software, by providing additional instruction, or delayed for a later version to be developed. Discount usability can be easily implemented in academic developmental activities. Our study resulted in the discovery and remediation of significant user problems, in addition to giving important insight into the novel methods built into the application.

  9. Evaluation of a Dry EEG System for Application of Passive Brain-Computer Interfaces in Autonomous Driving

    PubMed Central

    Zander, Thorsten O.; Andreessen, Lena M.; Berg, Angela; Bleuel, Maurice; Pawlitzki, Juliane; Zawallich, Lars; Krol, Laurens R.; Gramann, Klaus

    2017-01-01

    We tested the applicability and signal quality of a 16 channel dry electroencephalography (EEG) system in a laboratory environment and in a car under controlled, realistic conditions. The aim of our investigation was an estimation how well a passive Brain-Computer Interface (pBCI) can work in an autonomous driving scenario. The evaluation considered speed and accuracy of self-applicability by an untrained person, quality of recorded EEG data, shifts of electrode positions on the head after driving-related movements, usability, and complexity of the system as such and wearing comfort over time. An experiment was conducted inside and outside of a stationary vehicle with running engine, air-conditioning, and muted radio. Signal quality was sufficient for standard EEG analysis in the time and frequency domain as well as for the use in pBCIs. While the influence of vehicle-induced interferences to data quality was insignificant, driving-related movements led to strong shifts in electrode positions. In general, the EEG system used allowed for a fast self-applicability of cap and electrodes. The assessed usability of the system was still acceptable while the wearing comfort decreased strongly over time due to friction and pressure to the head. From these results we conclude that the evaluated system should provide the essential requirements for an application in an autonomous driving context. Nevertheless, further refinement is suggested to reduce shifts of the system due to body movements and increase the headset's usability and wearing comfort. PMID:28293184

  10. Evaluation of a Dry EEG System for Application of Passive Brain-Computer Interfaces in Autonomous Driving.

    PubMed

    Zander, Thorsten O; Andreessen, Lena M; Berg, Angela; Bleuel, Maurice; Pawlitzki, Juliane; Zawallich, Lars; Krol, Laurens R; Gramann, Klaus

    2017-01-01

    We tested the applicability and signal quality of a 16 channel dry electroencephalography (EEG) system in a laboratory environment and in a car under controlled, realistic conditions. The aim of our investigation was an estimation how well a passive Brain-Computer Interface (pBCI) can work in an autonomous driving scenario. The evaluation considered speed and accuracy of self-applicability by an untrained person, quality of recorded EEG data, shifts of electrode positions on the head after driving-related movements, usability, and complexity of the system as such and wearing comfort over time. An experiment was conducted inside and outside of a stationary vehicle with running engine, air-conditioning, and muted radio. Signal quality was sufficient for standard EEG analysis in the time and frequency domain as well as for the use in pBCIs. While the influence of vehicle-induced interferences to data quality was insignificant, driving-related movements led to strong shifts in electrode positions. In general, the EEG system used allowed for a fast self-applicability of cap and electrodes. The assessed usability of the system was still acceptable while the wearing comfort decreased strongly over time due to friction and pressure to the head. From these results we conclude that the evaluated system should provide the essential requirements for an application in an autonomous driving context. Nevertheless, further refinement is suggested to reduce shifts of the system due to body movements and increase the headset's usability and wearing comfort.

  11. Confirming, Classifying, and Prioritizing Needed Over-the-Bed Table Improvements via Methodological Triangulation.

    PubMed

    Manganelli, Joe; Threatt, Anthony; Brooks, Johnell O; Healy, Stan; Merino, Jessica; Yanik, Paul; Walker, Ian; Green, Keith

    2014-01-01

    This article presents the results of a qualitative study that confirmed, classified, and prioritized user needs for the design of a more useful, usable, and actively assistive over-the-bed table. Manganelli et al. (2014) generated a list of 74 needs for use in developing an actively assistive over-the-bed table. This present study assesses the value and importance of those needs. Fourteen healthcare subject matter experts and eight research and design subject matter experts engaged in a participatory and iterative research and design process. A mixed methods qualitative approach used methodological triangulation to confirm the value of the findings and ratings to establish importance. Open and closed card sorts and a Delphi study were used. Data analysis methods included frequency analysis, content analysis, and a modified Kano analysis. A table demonstrating the needs that are of high importance to both groups of subject matter experts and classification of the design challenges each represents was produced. Through this process, the list of 74 needs was refined to the 37 most important need statements for both groups. Designing a more useful, usable, and actively assistive over-the-bed table is primarily about the ability to position it optimally with respect to the user for any task, as well as improving ease of use and usability. It is also important to make explicit and discuss the differences in priorities and perspectives demonstrated between research and design teams and their clients. © 2014 Vendome Group, LLC.

  12. Earthdata Search Usability Study Process

    NASA Technical Reports Server (NTRS)

    Reese, Mark

    2016-01-01

    User experience (UX) design is the process of enhancing user satisfaction by improving various aspects of the user's interaction with an application or website. One aspect of UX design is usability, or the extent to which an application can be used to to accomplish tasks efficiently, effectively, and with satisfaction. NASA's Earthdata Search Client recently underwent a focused usability testing project to measure usability and gain valuable user feedback and insights to increase usability for its end-users. This presentation focuses on the process by which the usability tests were administered and the lessons learned throughout the process.

  13. Qualitative review of usability problems in health information systems for radiology.

    PubMed

    Dias, Camila Rodrigues; Pereira, Marluce Rodrigues; Freire, André Pimenta

    2017-12-01

    Radiology processes are commonly supported by Radiology Information System (RIS), Picture Archiving and Communication System (PACS) and other software for radiology. However, these information technologies can present usability problems that affect the performance of radiologists and physicians, especially considering the complexity of the tasks involved. The purpose of this study was to extract, classify and analyze qualitatively the usability problems in PACS, RIS and other software for radiology. A systematic review was performed to extract usability problems reported in empirical usability studies in the literature. The usability problems were categorized as violations of Nielsen and Molich's usability heuristics. The qualitative analysis indicated the causes and the effects of the identified usability problems. From the 431 papers initially identified, 10 met the study criteria. The analysis of the papers identified 90 instances of usability problems, classified into categories corresponding to established usability heuristics. The five heuristics with the highest number of instances of usability problems were "Flexibility and efficiency of use", "Consistency and standards", "Match between system and the real world", "Recognition rather than recall" and "Help and documentation", respectively. These problems can make the interaction time consuming, causing delays in tasks, dissatisfaction, frustration, preventing users from enjoying all the benefits and functionalities of the system, as well as leading to more errors and difficulties in carrying out clinical analyses. Furthermore, the present paper showed a lack of studies performed on systems for radiology, especially usability evaluations using formal methods of evaluation involving the final users. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Design and implementation of a hospital-based usability laboratory: insights from a Department of Veterans Affairs laboratory for health information technology.

    PubMed

    Russ, Alissa L; Weiner, Michael; Russell, Scott A; Baker, Darrell A; Fahner, W Jeffrey; Saleem, Jason J

    2012-12-01

    Although the potential benefits of more usable health information technologies (HIT) are substantial-reduced HIT support costs, increased work efficiency, and improved patient safety--human factors methods to improve usability are rarely employed. The US Department of Veterans Affairs (VA) has emerged as an early leader in establishing usability laboratories to inform the design of HIT, including its electronic health record. Experience with a usability laboratory at a VA Medical Center provides insights on how to design, implement, and leverage usability laboratories in the health care setting. The VA Health Services Research and Development Service Human-Computer Interaction & Simulation Laboratory emerged as one of the first VA usability laboratories and was intended to provide research-based findings about HIT designs. This laboratory supports rapid prototyping, formal usability testing, and analysis tools to assess existing technologies, alternative designs, and potential future technologies. RESULTS OF IMPLEMENTATION: Although the laboratory has maintained a research focus, it has become increasingly integrated with VA operations, both within the medical center and on a national VA level. With this resource, data-driven recommendations have been provided for the design of HIT applications before and after implementation. The demand for usability testing of HIT is increasing, and information on how to develop usability laboratories for the health care setting is often needed. This article may assist other health care organizations that want to invest in usability resources to improve HIT. The establishment and utilization of usability laboratories in the health care setting may improve HIT designs and promote safe, high-quality care for patients.

  15. Feasibility of a Web-Based Self-Management Intervention for Intermittent Urinary Catheter Users with Spinal Cord Injury

    PubMed Central

    Wilde, Mary H.; McMahon, James M.; Fairbanks, Eileen; Brasch, Judith; Parshall, Robert; Zhang, Feng; Miner, Sarah; Thayer, Deborah; Schneiderman, Dan; Harrington, Brian

    2016-01-01

    Purpose The purpose of this study was to evaluate the feasibility of a new web-based intermittent catheter self-management intervention. Design We tested the acceptability and usability of intervention components, which included multiple web-based materials (an online urinary diary adapted for mobile phone use and an educational booklet), three phone calls with a nurse, and a peer led discussion forum. Subjects and setting Thirty adults with spinal cord injury using an intermittent catheter for bladder drainage were enrolled; 26 participants received the nurses’ phone based consultations. Methods Preliminary effectiveness of new self-efficacy and self-management scales were evaluated using baseline and three month online surveys. Participants’ perceived value of the intervention components, self-management changes, and suggestions were assessed with data from the three month surveys followed by brief tape-recorded interviews. Results Several catheter practices improved somewhat over three months including. The frequency of catheterizations every 4–6 hours increased from 71% to 77%. Self-management of neurogenic bladder dysfunction increased significantly (P= .032); participant comments indicated that fluid intake was the biggest change. Catheter related self-efficacy and quality of life scores increased. The frequency of urinary tract infection and pain did not change significantly. For feasibility, intervention components, with the exception of the forum, were rated highly by the majority of participants for usefulness, satisfaction (desired information), and web-based usability. Conclusion Further testing of this intervention is recommended in a multi-site randomized clinical trial. PMID:27488740

  16. Implementation of a guideline for local health policy making by regional health services: exploring determinants of use by a web survey.

    PubMed

    Kuunders, Theo J M; Jacobs, Monique A M; Goor, Ien A M van de; Bon-Martens, Marja J H van; Oers, Hans A M van; Paulussen, Theo G W M

    2017-08-15

    Previous evaluation showed insufficient use of a national guideline for integrated local health policy by Regional Health Services (RHS) in the Netherlands. The guideline focuses on five health topics and includes five checklists to support integrated municipal health policies. This study explores the determinants of guideline use by regional Dutch health professionals. A web survey was send to 304 RHS health professionals. The questionnaire was based on a theory- and research-based framework of determinants of public health innovations. Main outcomes were guideline use and completeness of use, defined as the number of health topics and checklists used. Associations between determinants and (completeness of) guideline use were explored by multivariate regression models. The survey was started by 120 professionals (39%). Finally, results from 73 respondents (24%) were eligible for analyses. All 28 Dutch RHS organizations were represented in the final dataset. About half of the respondents (48%) used the guideline. The average score for completeness of use (potential range 1-10) was 2.37 (sd = 1.78; range 1-7). Knowledge, perceived task responsibility and usability were significantly related to guideline use in univariate analyses. Only usability remained significant in the multivariate model on guideline use. Only self-efficacy accounted for significant proportions of variance in completeness of use. The results imply that strategies to improve guideline use by RHSs should primarily target perceived usability. Self-efficacy appeared the primary target for improving completeness of guideline use. Methods for targeting these determinants in RHSs are discussed.

  17. Investigations of the influence of the profile thickness of the compressible plane flow through compressor cascades

    NASA Technical Reports Server (NTRS)

    Bahr, J.

    1978-01-01

    Flow-through cascade of an aircraft turbine compressor is studied experimentally over wide range of Reynolds numbers and subsonic Mach numbers; it was found that deterioration of flow properties due to decreasing Reynolds numbers is less noticeable on thin profiles than on thick ones; however, thick profiles are advantageous in compressors designed for efficient partial load behavior because thick profiles have a relatively large range of usable inlet flow angles.

  18. Effects and effectiveness of dynamic arm supports: a technical review.

    PubMed

    van der Heide, Loek A; Gelderblom, Gert Jan; de Witte, Luc P

    2015-01-01

    Numerous dynamic arm supports have been developed in recent decades to increase independence in the performance of activities of daily living. Much effort and money have been spent on their development and prescription, yet insight into their effects and effectiveness is lacking. This article is a systematic review of evaluations of dynamic arm supports. The 8 technical evaluations, 12 usability evaluations, and 27 outcome studies together make 47 evaluations. Technical evaluations were often used as input for new developments and directed at balancing quality, forces and torques, and range of motion of prototypes. Usability studies were mostly single-measure designs that had varying results as to whether devices were usable for potential users. An increased ability to perform activities of daily living and user satisfaction were reported in outcome studies. However, the use of dynamic arm supports in the home situation was reported to be low. Gaining insight into why devices are not used when their developers believe them to be effective seems crucial for every new dynamic arm support developed. The methodological quality of the outcome studies was often low, so it is important that this is improved in the future.

  19. Beyond Effectiveness: A Pragmatic Evaluation Framework for Learning and Continuous Quality Improvement of e-Learning Interventions in Healthcare.

    PubMed

    Dafalla, Tarig Dafalla Mohamed; Kushniruk, Andre W; Borycki, Elizabeth M

    2015-01-01

    A pragmatic evaluation framework for evaluating the usability and usefulness of an e-learning intervention for a patient clinical information scheduling system is presented in this paper. The framework was conceptualized based on two different but related concepts (usability and usefulness) and selection of appropriate and valid methods of data collection and analysis that included: (1) Low-Cost Rapid Usability Engineering (LCRUE), (2) Cognitive Task Analysis (CTA), (3) Heuristic Evaluation (HE) criteria for web-based learning, and (4) Software Usability Measurement Inventory (SUMI). The results of the analysis showed some areas where usability that were related to General Interface Usability (GIU), instructional design and content was problematic; some of which might account for the poorly rated aspects of usability when subjectively measured. This paper shows that using a pragmatic framework can be a useful way, not only for measuring the usability and usefulness, but also for providing a practical objective evidences for learning and continuous quality improvement of e-learning systems. The findings should be of interest to educators, developers, designers, researchers, and usability practitioners involved in the development of e-learning systems in healthcare. This framework could be an appropriate method for assessing the usability, usefulness and safety of health information systems both in the laboratory and in the clinical context.

  20. A methodology for evaluating the usability of audiovisual consumer electronic products.

    PubMed

    Kwahk, Jiyoung; Han, Sung H

    2002-09-01

    Usability evaluation is now considered an essential procedure in consumer product development. Many studies have been conducted to develop various techniques and methods of usability evaluation hoping to help the evaluators choose appropriate methods. However, planning and conducting usability evaluation requires considerations of a number of factors surrounding the evaluation process including the product, user, activity, and environmental characteristics. In this perspective, this study suggested a new methodology of usability evaluation through a simple, structured framework. The framework was outlined by three major components: the interface features of a product as design variables, the evaluation context consisting of user, product, activity, and environment as context variables, and the usability measures as dependent variables. Based on this framework, this study established methods to specify the product interface features, to define evaluation context, and to measure usability. The effectiveness of this methodology was demonstrated through case studies in which the usability of audiovisual products was evaluated by using the methods developed in this study. This study is expected to help the usability practitioners in consumer electronics industry in various ways. Most directly, it supports the evaluators' plan and conduct usability evaluation sessions in a systematic and structured manner. In addition, it can be applied to other categories of consumer products (such as appliances, automobiles, communication devices, etc.) with minor modifications as necessary.

  1. OPTIMIZING USABILITY OF AN ECONOMIC DECISION SUPPORT TOOL: PROTOTYPE OF THE EQUIPT TOOL.

    PubMed

    Cheung, Kei Long; Hiligsmann, Mickaël; Präger, Maximilian; Jones, Teresa; Józwiak-Hagymásy, Judit; Muñoz, Celia; Lester-George, Adam; Pokhrel, Subhash; López-Nicolás, Ángel; Trapero-Bertran, Marta; Evers, Silvia M A A; de Vries, Hein

    2018-01-01

    Economic decision-support tools can provide valuable information for tobacco control stakeholders, but their usability may impact the adoption of such tools. This study aims to illustrate a mixed-method usability evaluation of an economic decision-support tool for tobacco control, using the EQUIPT ROI tool prototype as a case study. A cross-sectional mixed methods design was used, including a heuristic evaluation, a thinking aloud approach, and a questionnaire testing and exploring the usability of the Return of Investment tool. A total of sixty-six users evaluated the tool (thinking aloud) and completed the questionnaire. For the heuristic evaluation, four experts evaluated the interface. In total twenty-one percent of the respondents perceived good usability. A total of 118 usability problems were identified, from which twenty-six problems were categorized as most severe, indicating high priority to fix them before implementation. Combining user-based and expert-based evaluation methods is recommended as these were shown to identify unique usability problems. The evaluation provides input to optimize usability of a decision-support tool, and may serve as a vantage point for other developers to conduct usability evaluations to refine similar tools before wide-scale implementation. Such studies could reduce implementation gaps by optimizing usability, enhancing in turn the research impact of such interventions.

  2. Combining usability evaluations to highlight the chain that leads from usability flaws to usage problems and then negative outcomes.

    PubMed

    Watbled, Ludivine; Marcilly, Romaric; Guerlinger, Sandra; Bastien, J-M Christian; Beuscart-Zéphir, Marie-Catherine; Beuscart, Régis

    2018-02-01

    Poor usability of health technology is thought to diminish work system performance, increase error rates and, potentially, harm patients. The present study (i) used a combination of usability evaluation methods to highlight the chain that leads from usability flaws to usage problems experienced by users and, ultimately, to negative patient outcomes, and (ii) validated this approach by studying two different discharge summary production systems. To comply with quality guidelines, the process of drafting and sending discharge summaries is increasingly being automated. However, the usability of these systems may modify their impact (or the absence thereof) in terms of production times and quality, and must therefore be evaluated. Here, we applied three successive techniques for usability evaluation (heuristic evaluation, user testing and field observation) to two discharge summary production systems (underpinned by different technologies). The systems' main usability flaws led respectively to an increase in the time need to produce a discharge summary and the risk of patient misidentification. Our results are discussed with regard to the possibility of linking the usability flaws, usage problems and the negative outcomes by successively applying three methods for evaluating usability (heuristic evaluation, user testing and in situ observations) throughout the system development life cycle. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. The Current Status of Usability Studies of Information Technologies in China: A Systematic Study

    PubMed Central

    Lei, Jianbo; Xu, Lufei; Meng, Qun; Zhang, Jiajie; Gong, Yang

    2014-01-01

    Objectives. To systematically review and analyze the current status and characteristics of usability studies in China in the field of information technology in general and in the field of healthcare in particular. Methods. We performed a quantitative literature analysis in three major Chinese academic databases and one English language database using Chinese search terms equivalent to the concept of usability. Results. Six hundred forty-seven publications were selected for analysis. We found that in China the literature on usability in the field of information technology began in 1994 and increased thereafter. The usability definitions from ISO 9241-11:1998 and Nielsen (1993) have been widely recognized and cited. Authors who have published several publications are rare. Fourteen journals have a publishing rate over 1%. Only nine publications about HIT were identified. Discussions. China's usability research started relatively late. There is a lack of organized research teams and dedicated usability journals. High-impact theoretical studies are scarce. On the application side, no original and systematic research frameworks have been developed. The understanding and definition of usability is not well synchronized with international norms. Besides, usability research in HIT is rare. Conclusions. More human and material resources need to be invested in China's usability research, particularly in HIT. PMID:25050362

  4. To twist or poke? A method for identifying usability issues with the rotary controller and touch screen for control of in-vehicle information systems.

    PubMed

    Harvey, Catherine; Stanton, Neville A; Pickering, Carl A; McDonald, Mike; Zheng, Pengjun

    2011-07-01

    In-vehicle information systems (IVIS) can be controlled by the user via direct or indirect input devices. In order to develop the next generation of usable IVIS, designers need to be able to evaluate and understand the usability issues associated with these two input types. The aim of this study was to investigate the effectiveness of a set of empirical usability evaluation methods for identifying important usability issues and distinguishing between the IVIS input devices. A number of usability issues were identified and their causal factors have been explored. These were related to the input type, the structure of the menu/tasks and hardware issues. In particular, the translation between inputs and on-screen actions and a lack of visual feedback for menu navigation resulted in lower levels of usability for the indirect device. This information will be useful in informing the design of new IVIS, with improved usability. STATEMENT OF RELEVANCE: This paper examines the use of empirical methods for distinguishing between direct and indirect IVIS input devices and identifying usability issues. Results have shown that the characteristics of indirect input devices produce more serious usability issues, compared with direct devices and can have a negative effect on the driver-vehicle interaction.

  5. Weathered antlers as a source of DNA

    Treesearch

    Roy G. Lopez; Paul Beier

    2012-01-01

    We tested antlers of Coues white-tailed (Odocoileus virginianus couesi) and mule deer (O. hemionus) in various stages of natural decomposition to determine the degree of weathering that cast antlers could endure and still yield usable DNA. Based on physical characteristics, we partitioned antlers into 7 weathering categories ranging from freshly cast (class 1) to...

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blay, J.A.

    The problem of the determination of micro-amounts of uranium in aqueous and organic phases in liquid-liquid extraction processes, original ones, and extraction residues was solved by a chromatographic separation of the uranium by means of columns of activated cellulose and further spectrophotometric evaluation using the thiocyanate complex in aqueous medium. The usable range is 5 to 200 mu g.

  7. TEAMS (Tele-Exercise and Multiple Sclerosis), a Tailored Telerehabilitation mHealth App: Participant-Centered Development and Usability Study

    PubMed Central

    Rimmer, James H; Johnson, George; Wilroy, Jereme; Young, Hui-Ju; Mehta, Tapan; Lai, Byron

    2018-01-01

    Background People with multiple sclerosis face varying levels of disability and symptoms, thus requiring highly trained therapists and/or exercise trainers to design personalized exercise programs. However, for people living in geographically isolated communities, access to such trained professionals can be challenging due to a number of barriers associated with cost, access to transportation, and travel distance. Generic mobile health exercise apps often fall short of what people with multiple sclerosis need to become physically active (ie, exercise content that has been adapted to accommodate a wide range of functional limitations). Objective This usability study describes the development process of the TEAMS (Tele-Exercise and Multiple Sclerosis) app, which is being used by people with multiple sclerosis in a large randomized controlled trial to engage in home-based telerehabilitation. Methods Twenty-one participants with disabilities (10 people with multiple sclerosis) were involved in the double iterative design, which included the simultaneous development of the app features and exercise content (exercise videos and articles). Framed within a user-centered design approach, the development process included 2 stages: ground-level creation (focus group followed by early stage evaluations and developments), and proof of concept through 2 usability tests. Usability (effectiveness, usefulness, and satisfaction) was evaluated using a mixed-methods approach. Results During testing of the app’s effectiveness, the second usability test resulted in an average of 1 problem per participant, a decrease of 53% compared to the initial usability test. Five themes were constructed from the qualitative data that related to app usefulness and satisfaction, namely: high perceived confidence for app usability, positive perceptions of exercise videos, viable exercise option at home, orientation and familiarity required for successful participation, and app issues. Participants acknowledged that the final app was ready to be delivered to the public after minor revisions. After including these revisions, the project team released the final app that is being used in the randomized controlled trial. Conclusions A multi-level user-centered development process resulted in the development of an inclusive exercise program for people with multiple sclerosis operated through an easy-to-use app. The promotion of exercise through self-regulated mHealth programs requires a stakeholder-driven approach to app development. This ensures that app and content match the preferences and functional abilities of the end user (ie, people with varying levels of multiple sclerosis). PMID:29798832

  8. TEAMS (Tele-Exercise and Multiple Sclerosis), a Tailored Telerehabilitation mHealth App: Participant-Centered Development and Usability Study.

    PubMed

    Thirumalai, Mohanraj; Rimmer, James H; Johnson, George; Wilroy, Jereme; Young, Hui-Ju; Mehta, Tapan; Lai, Byron

    2018-05-24

    People with multiple sclerosis face varying levels of disability and symptoms, thus requiring highly trained therapists and/or exercise trainers to design personalized exercise programs. However, for people living in geographically isolated communities, access to such trained professionals can be challenging due to a number of barriers associated with cost, access to transportation, and travel distance. Generic mobile health exercise apps often fall short of what people with multiple sclerosis need to become physically active (ie, exercise content that has been adapted to accommodate a wide range of functional limitations). This usability study describes the development process of the TEAMS (Tele-Exercise and Multiple Sclerosis) app, which is being used by people with multiple sclerosis in a large randomized controlled trial to engage in home-based telerehabilitation. Twenty-one participants with disabilities (10 people with multiple sclerosis) were involved in the double iterative design, which included the simultaneous development of the app features and exercise content (exercise videos and articles). Framed within a user-centered design approach, the development process included 2 stages: ground-level creation (focus group followed by early stage evaluations and developments), and proof of concept through 2 usability tests. Usability (effectiveness, usefulness, and satisfaction) was evaluated using a mixed-methods approach. During testing of the app's effectiveness, the second usability test resulted in an average of 1 problem per participant, a decrease of 53% compared to the initial usability test. Five themes were constructed from the qualitative data that related to app usefulness and satisfaction, namely: high perceived confidence for app usability, positive perceptions of exercise videos, viable exercise option at home, orientation and familiarity required for successful participation, and app issues. Participants acknowledged that the final app was ready to be delivered to the public after minor revisions. After including these revisions, the project team released the final app that is being used in the randomized controlled trial. A multi-level user-centered development process resulted in the development of an inclusive exercise program for people with multiple sclerosis operated through an easy-to-use app. The promotion of exercise through self-regulated mHealth programs requires a stakeholder-driven approach to app development. This ensures that app and content match the preferences and functional abilities of the end user (ie, people with varying levels of multiple sclerosis). ©Mohanraj Thirumalai, James H Rimmer, George Johnson, Jereme Wilroy, Hui-Ju Young, Tapan Mehta, Byron Lai. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 24.05.2018.

  9. Usability Assessment of Secure Messaging for Clinical Document Sharing between Health Care Providers and Patients.

    PubMed

    Jahn, Michelle A; Porter, Brian W; Patel, Himalaya; Zillich, Alan J; Simon, Steven R; Russ, Alissa L

    2018-04-01

     Web-based patient portals feature secure messaging systems that enable health care providers and patients to communicate information. However, little is known about the usability of these systems for clinical document sharing.  This article evaluates the usability of a secure messaging system for providers and patients in terms of its ability to support sharing of electronic clinical documents.  We conducted usability testing with providers and patients in a human-computer interaction laboratory at a Midwestern U.S. hospital. Providers sent a medication list document to a fictitious patient via secure messaging. Separately, patients retrieved the clinical document from a secure message and returned it to a fictitious provider. We collected use errors, task completion, task time, and satisfaction.  Twenty-nine individuals participated: 19 providers (6 physicians, 6 registered nurses, and 7 pharmacists) and 10 patients. Among providers, 11 (58%) attached and sent the clinical document via secure messaging without requiring assistance, in a median (range) of 4.5 (1.8-12.7) minutes. No patients completed tasks without moderator assistance. Patients accessed the secure messaging system within 3.6 (1.2-15.0) minutes; retrieved the clinical document within 0.8 (0.5-5.7) minutes; and sent the attached clinical document in 6.3 (1.5-18.1) minutes. Although median satisfaction ratings were high, with 5.8 for providers and 6.0 for patients (scale, 0-7), we identified 36 different use errors. Physicians and pharmacists requested additional features to support care coordination via health information technology, while nurses requested features to support efficiency for their tasks.  This study examined the usability of clinical document sharing, a key feature of many secure messaging systems. Our results highlight similarities and differences between provider and patient end-user groups, which can inform secure messaging design to improve learnability and efficiency. The observations suggest recommendations for improving the technical aspects of secure messaging for clinical document sharing. Schattauer GmbH Stuttgart.

  10. Validating a Web-based Diabetes Education Program in continuing nursing education: knowledge and competency change and user perceptions on usability and quality

    PubMed Central

    2014-01-01

    Background Nurses as the members of health care professionals need to improve their knowledge and competencies particularly in diabetes mellitus through continuing nursing education programs. E-learning is an indirect method of training that can meet nurses’ educational needs. This study is aimed at validating a web-based diabetes education program through measurement of nurses’ knowledge and clinical competency in diabetes and nurses’ perception about its usability and quality. Methods This Quasi-experimental research was conducted on a single group of 31 nurses employed in hospitals affiliated with Shiraz University of Medical Sciences. We used a 125 MCQ knowledge test and Objective Structured Clinical Exam (OSCE) to measure knowledge and clinical competency of nurses in diabetes before and after intervention. A Learning Management System (LMS) was designed to provide educational content in the form of 12 multimedia electronic modules, interactive tests; a forum and learning activities. Nurses were trained for two months in this system after which the post-test was administered. Each nurse completed two questionnaires for measurement of their perceptions on usability and quality. We used descriptive statistics for demographic and descriptive data analysis. Paired t-test was used to compare pre- and post-data using SPSS. Results The findings showed significant differences in knowledge scores (p < 0.001), total score of clinical competencies (p < 0.001), and all ten assessed clinical competencies. The range of ratings given by participants varied on the six usability variables of Web-based training (2.96-4.23 from 5) and eight quality variables of Web-based training (3.58-4.37 from 5). Conclusion Web-based education increased nurses’ knowledge and competencies in diabetes. They positively evaluated Web-based learning usability and quality. It is hoped that this course will have a positive clinical outcomes. PMID:26086025

  11. Validating a Web-based Diabetes Education Program in continuing nursing education: knowledge and competency change and user perceptions on usability and quality.

    PubMed

    Moattari, Marzieh; Moosavinasab, Elham; Dabbaghmanesh, Mohammad Hossein; ZarifSanaiey, Nahid

    2014-01-01

    Nurses as the members of health care professionals need to improve their knowledge and competencies particularly in diabetes mellitus through continuing nursing education programs. E-learning is an indirect method of training that can meet nurses' educational needs. This study is aimed at validating a web-based diabetes education program through measurement of nurses' knowledge and clinical competency in diabetes and nurses' perception about its usability and quality. This Quasi-experimental research was conducted on a single group of 31 nurses employed in hospitals affiliated with Shiraz University of Medical Sciences. We used a 125 MCQ knowledge test and Objective Structured Clinical Exam (OSCE) to measure knowledge and clinical competency of nurses in diabetes before and after intervention. A Learning Management System (LMS) was designed to provide educational content in the form of 12 multimedia electronic modules, interactive tests; a forum and learning activities. Nurses were trained for two months in this system after which the post-test was administered. Each nurse completed two questionnaires for measurement of their perceptions on usability and quality. We used descriptive statistics for demographic and descriptive data analysis. Paired t-test was used to compare pre- and post-data using SPSS. The findings showed significant differences in knowledge scores (p < 0.001), total score of clinical competencies (p < 0.001), and all ten assessed clinical competencies. The range of ratings given by participants varied on the six usability variables of Web-based training (2.96-4.23 from 5) and eight quality variables of Web-based training (3.58-4.37 from 5). Web-based education increased nurses' knowledge and competencies in diabetes. They positively evaluated Web-based learning usability and quality. It is hoped that this course will have a positive clinical outcomes.

  12. Using a fuzzy comprehensive evaluation method to determine product usability: A test case

    PubMed Central

    Zhou, Ronggang; Chan, Alan H. S.

    2016-01-01

    BACKGROUND: In order to take into account the inherent uncertainties during product usability evaluation, Zhou and Chan [1] proposed a comprehensive method of usability evaluation for products by combining the analytic hierarchy process (AHP) and fuzzy evaluation methods for synthesizing performance data and subjective response data. This method was designed to provide an integrated framework combining the inevitable vague judgments from the multiple stages of the product evaluation process. OBJECTIVE AND METHODS: In order to illustrate the effectiveness of the model, this study used a summative usability test case to assess the application and strength of the general fuzzy usability framework. To test the proposed fuzzy usability evaluation framework [1], a standard summative usability test was conducted to benchmark the overall usability of a specific network management software. Based on the test data, the fuzzy method was applied to incorporate both the usability scores and uncertainties involved in the multiple components of the evaluation. Then, with Monte Carlo simulation procedures, confidence intervals were used to compare the reliabilities among the fuzzy approach and two typical conventional methods combining metrics based on percentages. RESULTS AND CONCLUSIONS: This case study showed that the fuzzy evaluation technique can be applied successfully for combining summative usability testing data to achieve an overall usability quality for the network software evaluated. Greater differences of confidence interval widths between the method of averaging equally percentage and weighted evaluation method, including the method of weighted percentage averages, verified the strength of the fuzzy method. PMID:28035942

  13. Using a fuzzy comprehensive evaluation method to determine product usability: A test case.

    PubMed

    Zhou, Ronggang; Chan, Alan H S

    2017-01-01

    In order to take into account the inherent uncertainties during product usability evaluation, Zhou and Chan [1] proposed a comprehensive method of usability evaluation for products by combining the analytic hierarchy process (AHP) and fuzzy evaluation methods for synthesizing performance data and subjective response data. This method was designed to provide an integrated framework combining the inevitable vague judgments from the multiple stages of the product evaluation process. In order to illustrate the effectiveness of the model, this study used a summative usability test case to assess the application and strength of the general fuzzy usability framework. To test the proposed fuzzy usability evaluation framework [1], a standard summative usability test was conducted to benchmark the overall usability of a specific network management software. Based on the test data, the fuzzy method was applied to incorporate both the usability scores and uncertainties involved in the multiple components of the evaluation. Then, with Monte Carlo simulation procedures, confidence intervals were used to compare the reliabilities among the fuzzy approach and two typical conventional methods combining metrics based on percentages. This case study showed that the fuzzy evaluation technique can be applied successfully for combining summative usability testing data to achieve an overall usability quality for the network software evaluated. Greater differences of confidence interval widths between the method of averaging equally percentage and weighted evaluation method, including the method of weighted percentage averages, verified the strength of the fuzzy method.

  14. Analysis of group-velocity dispersion of high-frequency Rayleigh waves for near-surface applications

    USGS Publications Warehouse

    Luo, Y.; Xia, J.; Xu, Y.; Zeng, C.

    2011-01-01

    The Multichannel Analysis of Surface Waves (MASW) method is an efficient tool to obtain the vertical shear (S)-wave velocity profile using the dispersive characteristic of Rayleigh waves. Most MASW researchers mainly apply Rayleigh-wave phase-velocity dispersion for S-wave velocity estimation with a few exceptions applying Rayleigh-wave group-velocity dispersion. Herein, we first compare sensitivities of fundamental surface-wave phase velocities with group velocities with three four-layer models including a low-velocity layer or a high-velocity layer. Then synthetic data are simulated by a finite difference method. Images of group-velocity dispersive energy of the synthetic data are generated using the Multiple Filter Analysis (MFA) method. Finally we invert a high-frequency surface-wave group-velocity dispersion curve of a real-world example. Results demonstrate that (1) the sensitivities of group velocities are higher than those of phase velocities and usable frequency ranges are wider than that of phase velocities, which is very helpful in improving inversion stability because for a stable inversion system, small changes in phase velocities do not result in a large fluctuation in inverted S-wave velocities; (2) group-velocity dispersive energy can be measured using single-trace data if Rayleigh-wave fundamental-mode energy is dominant, which suggests that the number of shots required in data acquisition can be dramatically reduced and the horizontal resolution can be greatly improved using analysis of group-velocity dispersion; and (3) the suspension logging results of the real-world example demonstrate that inversion of group velocities generated by the MFA method can successfully estimate near-surface S-wave velocities. ?? 2011 Elsevier B.V.

  15. 36 CFR 1193.31 - Accessibility and usability.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 36 Parks, Forests, and Public Property 3 2011-07-01 2011-07-01 false Accessibility and usability... COMPLIANCE BOARD TELECOMMUNICATIONS ACT ACCESSIBILITY GUIDELINES Requirements for Accessibility and Usability § 1193.31 Accessibility and usability. When required by § 1193.21, telecommunications equipment and...

  16. 36 CFR 1193.31 - Accessibility and usability.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Accessibility and usability... COMPLIANCE BOARD TELECOMMUNICATIONS ACT ACCESSIBILITY GUIDELINES Requirements for Accessibility and Usability § 1193.31 Accessibility and usability. When required by § 1193.21, telecommunications equipment and...

  17. 36 CFR 1193.31 - Accessibility and usability.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 36 Parks, Forests, and Public Property 3 2014-07-01 2014-07-01 false Accessibility and usability... COMPLIANCE BOARD TELECOMMUNICATIONS ACT ACCESSIBILITY GUIDELINES Requirements for Accessibility and Usability § 1193.31 Accessibility and usability. When required by § 1193.21, telecommunications equipment and...

  18. 36 CFR 1193.31 - Accessibility and usability.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 36 Parks, Forests, and Public Property 3 2012-07-01 2012-07-01 false Accessibility and usability... COMPLIANCE BOARD TELECOMMUNICATIONS ACT ACCESSIBILITY GUIDELINES Requirements for Accessibility and Usability § 1193.31 Accessibility and usability. When required by § 1193.21, telecommunications equipment and...

  19. Usability Evaluation of Electronic Health Record System around Clinical Notes Usage-An Ethnographic Study.

    PubMed

    Rizvi, Rubina F; Marquard, Jenna L; Hultman, Gretchen M; Adam, Terrence J; Harder, Kathleen A; Melton, Genevieve B

    2017-10-01

    Background A substantial gap exists between current Electronic Health Record (EHR) usability and potential optimal usability. One of the fundamental reasons for this discrepancy is poor incorporation of a User-Centered Design (UCD) approach during the Graphical User Interface (GUI) development process. Objective To evaluate usability strengths and weaknesses of two widely implemented EHR GUIs for critical clinical notes usage tasks. Methods Twelve Internal Medicine resident physicians interacting with one of the two EHR systems (System-1 at Location-A and System-2 at Location-B) were observed by two usability evaluators employing an ethnographic approach. User comments and observer findings were analyzed for two critical tasks: (1) clinical notes entry and (2) related information-seeking tasks. Data were analyzed from two standpoints: (1) usability references categorized by usability evaluators as positive, negative, or equivocal and (2) usability impact of each feature measured through a 7-point severity rating scale. Findings were also validated by user responses to a post observation questionnaire. Results For clinical notes entry, System-1 surpassed System-2 with more positive (26% vs. 12%) than negative (12% vs. 34%) usability references. Greatest impact features on EHR usability (severity score pertaining to each feature) for clinical notes entry were: autopopulation (6), screen options (5.5), communication (5), copy pasting (4.5), error prevention (4.5), edit ability (4), and dictation and transcription (3.5). Both systems performed equally well on information-seeking tasks and features with greatest impacts on EHR usability were navigation for notes (7) and others (e.g., looking for ancillary data; 5.5). Ethnographic observations were supported by follow-up questionnaire responses. Conclusion This study provides usability-specific insights to inform future, improved, EHR interface that is better aligned with UCD approach.

  20. Marketing through Usability.

    ERIC Educational Resources Information Center

    Morgan, Eric Lease

    1999-01-01

    Suggests that one of the best ways to get word-of-mouth marketing of library technology is to provide "usable" products and services. Provides an international standards definition on usability and notes that understanding usability combines an understanding of user needs/wants with an understanding of goals, functions, and limitations…

  1. Injection locking of violet laser diodes with a 3.2 GHz offset frequency for driving Raman transitions in 43Ca+.

    PubMed

    Keitch, B C; Thomas, N R; Lucas, D M

    2013-03-15

    Two cw single-mode violet (397 nm) diode lasers are locked to a single external-cavity master diode laser by optical injection locking. A double-pass 1.6 GHz acousto-optic modulator is used to provide a 3.2 GHz offset frequency between the two slave lasers. We achieve up to 20 mW usable output in each slave beam, with as little as 25 μW of injection power at room temperature. An optical heterodyne measurement of the beat note between the two slave beams gives a linewidth of ≤10 Hz at 3.2 GHz. We also estimate the free-running linewidth of the master laser to be approximately 3 MHz by optical heterodyning with a similar device.

  2. Usability of a new disposable autoinjector platform device: results of a formative study conducted with a broad user population.

    PubMed

    Lange, Jakob; Richard, Philipp; Bradley, Nick

    2015-01-01

    This article presents a late-stage formative usability study of an autoinjector platform device. Such devices are used for the subcutaneous delivery of biopharmaceuticals, primarily for self-administration by the patient. Previous usability work on autoinjectors reported in the literature has been specific to single indications. This study was instead conducted with a broad user population, defined to represent user characteristics across a range of indications. The goals of the study were to evaluate whether users could use the devices safely and effectively, and could understand the instructions for use (IFU) as well as the accompanying training. Further objectives were to capture any usability issues and to obtain participants' subjective ratings on the IFU and training as well as the confidence and comfort in using the device. A total of 43 participants in 5 groups received training and performed simulated injections either into an injection pad or a mannequin. All participants were able to successfully use the device. The device was well appreciated by all users, with a reported degree of confidence in using the device of 98%, of user comfort of 93%, and of comprehensibility of IFU and training of 98%. These values are higher than other comparable results reported in the literature. The presence of both audible and visible feedback during injection was seen to be a significant factor contributing to injection success. The observation that the device can be safely and efficiently used by all tested user groups provides confidence that the device and IFU in their current form will pass future summative testing in specific applications.

  3. Usability, Acceptability, and Impact of a Pediatric Teledermatology Mobile Health Application.

    PubMed

    Fiks, Alexander G; Fleisher, Linda; Berrigan, Lindsay; Sykes, Emily; Mayne, Stephanie L; Gruver, Rachel; Halkyard, Katherine; Jew, Olivia S; FitzGerald, Patrick; Winston, Flaura; McMahon, Patrick

    2018-03-01

    Pediatric dermatology appointment wait times often exceed several months. We evaluated the usability, acceptability, and clinical impact of a store-and-forward teledermatology mobile application (app) linking families with pediatric dermatologists. Parents of children age 6 weeks to 17 years or individuals 18-21 years old were invited (by e-mail or referral) to participate in this single group, prospective study. Within the app, users photographed the skin condition, answered questions, and submitted their case for review. One pediatric dermatologist viewed cases, diagnosed conditions, and provided instructions and prescriptions. User surveys immediately following app use and 1 week later, supplemented by electronic logs, assessed usability, acceptability, and impact. One hundred ninety-seven parents and one adolescent submitted cases within 39 days of invitation. App users were more likely to be white than those in the population invited (67% vs. 34%, p < 0.001) and their children were slightly younger (mean 7.3 vs. 9.0 years, p < 0.001). A majority, 83% found the app easy to use, 97% felt that submitting a case took "the right amount of time," 87% were satisfied, and 93% would use the app again. Prescription receipt was associated with increased app satisfaction (p = 0.008). The median user received a response in 2.8 h (interquartile range 1.1-6.4). Had the app been unavailable, 44% reported that they would have waited for primary care, 32% for a dermatology appointment, and 7% would have gone to an urgent care clinic. A mobile health app allowing families to directly consult a pediatric dermatologist was usable, acceptable, and expedited care.

  4. Defining Usability: How Library Practice Differs from Published Research

    ERIC Educational Resources Information Center

    Chen, Yu-Hui; Germain, Carol Anne; Rorissa, Abebe

    2011-01-01

    Library/information science professionals need a clearly articulated definition of usability/Web usability to implement intuitive websites. In this study, the authors analyzed usability definitions provided by the ARL library professionals and those found in the library/information science and computer science-information systems literature.…

  5. 48 CFR 552.270-20 - Payment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., usable square footage delivered will be confirmed by either: (1) The Government's measurement of plans... of usable square footage stated in the lease. (c) If the amount of usable square footage delivered is... space delivered and the annual rental will be adjusted as follows: Usable square feet (USF) not...

  6. An evaluation of patients' experienced usability of a diabetes mHealth system using a multi-method approach.

    PubMed

    Georgsson, Mattias; Staggers, Nancy

    2016-02-01

    mHealth systems are becoming more common to aid patients in their diabetes self-management, but recent studies indicate a need for thorough evaluation of patients' experienced usability. Current evaluations lack a multi-method design for data collection and structured methods for data analyses. The purpose of this study was to provide a feasibility test of a multi-method approach for both data collection and data analyses for patients' experienced usability of a mHealth system for diabetes type 2 self-management. A random sample of 10 users was selected from a larger clinical trial. Data collection methods included user testing with eight representative tasks and Think Aloud protocol, a semi-structured interview and a questionnaire on patients' experiences using the system. The Framework Analysis (FA) method and Usability Problem Taxonomy (UPT) were used to structure, code and analyze the results. A usability severity rating was assigned after classification. The combined methods resulted in a total of 117 problems condensed into 19 usability issues with an average severity rating of 2.47 or serious. The usability test detected 50% of the initial usability problems, followed by the post-interview at 29%. The usability test found 18 of 19 consolidated usability problems while the questionnaire uncovered one unique issue. Patients experienced most usability problems (8) in the Glucose Readings View when performing complex tasks such as adding, deleting, and exporting glucose measurements. The severity ratings were the highest for the Glucose Diary View, Glucose Readings View, and Blood Pressure View with an average severity rating of 3 (serious). Most of the issues were classified under the artifact component of the UPT and primary categories of Visualness (7) and Manipulation (6). In the UPT task component, most issues were in the primary category Task-mapping (12). Multiple data collection methods yielded a more comprehensive set of usability issues. Usability testing uncovered the largest volume of usability issues, followed by interviewing and then the questionnaire. The interview did not surface any unique consolidated usability issues while the questionnaire surfaced one. The FA and UPT were valuable in structuring and classifying problems. The resulting descriptions serve as a communication tool in problem solving and programming. We recommend the usage of multiple methods in data collection and employing the FA and UPT in data analyses for future usability testing. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  7. The value of Retrospective and Concurrent Think Aloud in formative usability testing of a physician data query tool.

    PubMed

    Peute, Linda W P; de Keizer, Nicolette F; Jaspers, Monique W M

    2015-06-01

    To compare the performance of the Concurrent (CTA) and Retrospective (RTA) Think Aloud method and to assess their value in a formative usability evaluation of an Intensive Care Registry-physician data query tool designed to support ICU quality improvement processes. Sixteen representative intensive care physicians participated in the usability evaluation study. Subjects were allocated to either the CTA or RTA method by a matched randomized design. Each subject performed six usability-testing tasks of varying complexity in the query tool in a real-working context. Methods were compared with regard to number and type of problems detected. Verbal protocols of CTA and RTA were analyzed in depth to assess differences in verbal output. Standardized measures were applied to assess thoroughness in usability problem detection weighted per problem severity level and method overall effectiveness in detecting usability problems with regard to the time subjects spent per method. The usability evaluation of the data query tool revealed a total of 43 unique usability problems that the intensive care physicians encountered. CTA detected unique usability problems with regard to graphics/symbols, navigation issues, error messages, and the organization of information on the query tool's screens. RTA detected unique issues concerning system match with subjects' language and applied terminology. The in-depth verbal protocol analysis of CTA provided information on intensive care physicians' query design strategies. Overall, CTA performed significantly better than RTA in detecting usability problems. CTA usability problem detection effectiveness was 0.80 vs. 0.62 (p<0.05) respectively, with an average difference of 42% less time spent per subject compared to RTA. In addition, CTA was more thorough in detecting usability problems of a moderate (0.85 vs. 0.7) and severe nature (0.71 vs. 0.57). In this study, the CTA is more effective in usability-problem detection and provided clarification of intensive care physician query design strategies to inform redesign of the query tool. However, CTA does not outperform RTA. The RTA additionally elucidated unique usability problems and new user requirements. Based on the results of this study, we recommend the use of CTA in formative usability evaluation studies of health information technology. However, we recommend further research on the application of RTA in usability studies with regard to user expertise and experience when focusing on user profile customized (re)design. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Advancing Usability Evaluation through Human Reliability Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ronald L. Boring; David I. Gertman

    2005-07-01

    This paper introduces a novel augmentation to the current heuristic usability evaluation methodology. The SPAR-H human reliability analysis method was developed for categorizing human performance in nuclear power plants. Despite the specialized use of SPAR-H for safety critical scenarios, the method also holds promise for use in commercial off-the-shelf software usability evaluations. The SPAR-H method shares task analysis underpinnings with human-computer interaction, and it can be easily adapted to incorporate usability heuristics as performance shaping factors. By assigning probabilistic modifiers to heuristics, it is possible to arrive at the usability error probability (UEP). This UEP is not a literal probabilitymore » of error but nonetheless provides a quantitative basis to heuristic evaluation. When combined with a consequence matrix for usability errors, this method affords ready prioritization of usability issues.« less

  9. Promoting Usability in Organizations with a New Health Usability Model: Implications for Nursing Informatics

    PubMed Central

    Staggers, Nancy; Rodney, Melanie

    2012-01-01

    Usability issues with products such as Electronic Health Records (EHRs) are of global interest to nursing informaticists. Although improvements in patient safety, clinical productivity and effectiveness are possible when usability principles and practices are in place, most organizations do not embrace usability. This paper presents a new Health Usability Maturity Model consisting of 5 phases: unrecognized, preliminary, implemented, integrated and strategic. Within each level various aspects are discussed including focus on users, management, education, resources, processes and infrastructure. Nurse informaticists may use this new model as a guide for assessing their organization’s level of usability and transitioning to the next level. Using tactics outlined here, nurse informaticists may also serve as catalysts for change and lead efforts to improve the user experience in organizations across industry, academe and healthcare settings. PMID:24199128

  10. Systematic Review Protocol to Assess the Effectiveness of Usability Questionnaires in mHealth App Studies

    PubMed Central

    Bao, Jie; Parmanto, Bambang

    2017-01-01

    Background Usability questionnaires have a wide use in mobile health (mHealth) app usability studies. However, no systematic review has been conducted for assessing the effectiveness of these questionnaires. Objective This paper describes a protocol for conducting a systematic review of published questionnaire-based mHealth app usability studies. Methods In this systematic review, we will select recently published (2008-2017) articles from peer-reviewed journals and conferences that describe mHealth app usability studies and implement at least one usability questionnaire. The search strategy will include terms such as “mobile app” and “usability.” Multiple databases such as PubMed, CINAHL, IEEE Xplore, ACM Digital Library, and INSPEC will be searched. There will be 2 independent reviewers in charge of screening titles and abstracts as well as determining those articles that should be included for a full-text review. The third reviewer will act as a mediator between the other 2 reviewers. Moreover, a data extraction form will be created and used during the full article data analysis. Notably, the Preferred Reporting Items for Systematic Review and Meta-Analysis Protocols (PRISMA-P) guidelines will be followed in reporting this protocol. Results A preliminary search produced 1271 articles, 40 of which are duplicate records. The inclusion-exclusion criteria are being strictly followed in performing the ongoing study selection. Conclusions Usability questionnaires are an important tool in mHealth app usability studies. This review will summarize the usability questionnaires used in published research articles while assessing the efficacy of these questionnaires in determining the usability of mHealth apps. PMID:28765101

  11. Investigation of the Usability of Computerized Critical Care Information Systems in Germany.

    PubMed

    von Dincklage, Falk; Suchodolski, Klaudiusz; Lichtner, Gregor; Friesdorf, Wolfgang; Podtschaske, Beatrice; Ragaller, Maximilian

    2017-01-01

    The term "usability" describes how effectively, efficiently, and with what level of user satisfaction an information system can be used to accomplish specific goals. Computerized critical care information systems (CCISs) with high usability increase quality of care and staff satisfaction, while reducing medication errors. Conversely, systems lacking usability can interrupt clinical workflow, facilitate errors, and increase charting time. The aim of this study was to investigate and compare usability across CCIS currently used in Germany. In this study, German intensive care unit (ICU) nurses and physicians completed a specialized, previously validated, web-based questionnaire. The questionnaire assessed CCIS usability based on three rating models: an overall rating of the systems, a model rating technical usability, and a model rating task-specific usability. We analyzed results from 535 survey participants and compared eight different CCIS commonly used in Germany. Our results showed that usability strongly differs across the compared systems. The system ICUData had the best overall rating and technical usability, followed by the platforms ICM and MetaVision. The same three systems performed best in the rating of task-specific usability without significant differences between each other. Across all systems, overall ratings were more dependent on ease-of-use aspects than on aspects of utility/functionality, and the general scope of the functions offered was rated better than how well the functions are realized. Our results suggest that manufacturers should shift some of their effort away from the development of new features and focus more on improving the ease-of-use and quality of existing features.

  12. 76 FR 8715 - Proposed Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-15

    .... Title; Associated Form; and OMB Number: Electronic Health Record (EHR) Usability Survey; OMB Control... longitudinal measure of how end-users perceive the usability of the Department of Defense (DoD) suite of... usability of a system. This usability attribute describes the ease with which people can use the system to...

  13. 77 FR 25707 - Submission for OMB Review; Comment request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-01

    ... and OMB Number: Electronic Health Record (EHR) Usability Survey; OMB Control Number 0720-TBD. Type of... information collection is to develop a longitudinal measure of how end-users perceive the usability of the... the focus has shifted towards understanding the usability of a system. This usability attribute...

  14. 36 CFR § 1193.31 - Accessibility and usability.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 36 Parks, Forests, and Public Property 3 2013-07-01 2012-07-01 true Accessibility and usability. § 1193.31 Section § 1193.31 Parks, Forests, and Public Property ARCHITECTURAL AND TRANSPORTATION... and Usability § 1193.31 Accessibility and usability. When required by § 1193.21, telecommunications...

  15. Unsupervised frequency-recognition method of SSVEPs using a filter bank implementation of binary subband CCA

    NASA Astrophysics Data System (ADS)

    Rabiul Islam, Md; Khademul Islam Molla, Md; Nakanishi, Masaki; Tanaka, Toshihisa

    2017-04-01

    Objective. Recently developed effective methods for detection commands of steady-state visual evoked potential (SSVEP)-based brain-computer interface (BCI) that need calibration for visual stimuli, which cause more time and fatigue prior to the use, as the number of commands increases. This paper develops a novel unsupervised method based on canonical correlation analysis (CCA) for accurate detection of stimulus frequency. Approach. A novel unsupervised technique termed as binary subband CCA (BsCCA) is implemented in a multiband approach to enhance the frequency recognition performance of SSVEP. In BsCCA, two subbands are used and a CCA-based correlation coefficient is computed for the individual subbands. In addition, a reduced set of artificial reference signals is used to calculate CCA for the second subband. The analyzing SSVEP is decomposed into multiple subband and the BsCCA is implemented for each one. Then, the overall recognition score is determined by a weighted sum of the canonical correlation coefficients obtained from each band. Main results. A 12-class SSVEP dataset (frequency range: 9.25-14.75 Hz with an interval of 0.5 Hz) for ten healthy subjects are used to evaluate the performance of the proposed method. The results suggest that BsCCA significantly improves the performance of SSVEP-based BCI compared to the state-of-the-art methods. The proposed method is an unsupervised approach with averaged information transfer rate (ITR) of 77.04 bits min-1 across 10 subjects. The maximum individual ITR is 107.55 bits min-1 for 12-class SSVEP dataset, whereas, the ITR of 69.29 and 69.44 bits min-1 are achieved with CCA and NCCA respectively. Significance. The statistical test shows that the proposed unsupervised method significantly improves the performance of the SSVEP-based BCI. It can be usable in real world applications.

  16. Validation of High Frequency (HF) Propagation Prediction Models in the Arctic region

    NASA Astrophysics Data System (ADS)

    Athieno, R.; Jayachandran, P. T.

    2014-12-01

    Despite the emergence of modern techniques for long distance communication, Ionospheric communication in the high frequency (HF) band (3-30 MHz) remains significant to both civilian and military users. However, the efficient use of the ever-varying ionosphere as a propagation medium is dependent on the reliability of ionospheric and HF propagation prediction models. Most available models are empirical implying that data collection has to be sufficiently large to provide good intended results. The models we present were developed with little data from the high latitudes which necessitates their validation. This paper presents the validation of three long term High Frequency (HF) propagation prediction models over a path within the Arctic region. Measurements of the Maximum Usable Frequency for a 3000 km range (MUF (3000) F2) for Resolute, Canada (74.75° N, 265.00° E), are obtained from hand-scaled ionograms generated by the Canadian Advanced Digital Ionosonde (CADI). The observations have been compared with predictions obtained from the Ionospheric Communication Enhanced Profile Analysis Program (ICEPAC), Voice of America Coverage Analysis Program (VOACAP) and International Telecommunication Union Recommendation 533 (ITU-REC533) for 2009, 2011, 2012 and 2013. A statistical analysis shows that the monthly predictions seem to reproduce the general features of the observations throughout the year though it is more evident in the winter and equinox months. Both predictions and observations show a diurnal and seasonal variation. The analysed models did not show large differences in their performances. However, there are noticeable differences across seasons for the entire period analysed: REC533 gives a better performance in winter months while VOACAP has a better performance for both equinox and summer months. VOACAP gives a better performance in the daily predictions compared to ICEPAC though, in general, the monthly predictions seem to agree more with the observations compared to the daily predictions.

  17. System performance testing of the DVA1 radio telescope

    NASA Astrophysics Data System (ADS)

    Knee, Lewis B. G.; Baker, Lynn A.; Gray, Andrew D.; Hovey, Gary J.; Kesteven, Michael J.; Lacy, Gordon; Robishaw, Timothy

    2016-07-01

    DVA1 (Dish Verification Antenna 1) is a highly innovative rim-supported single-piece composite-material dish radio telescope developed at the National Research Council Canada (NRC). It has a feed-high offset Gregorian optical design with a primary effective diameter of 15 m. DVA1 has been undergoing mechanical and astronomical system tests since 2014. Astronomical measurements were made in L band using a prototype front end developed for MeerKAT by EMSS Antennas (South Africa), including aperture efficiency, beam profiles, sensitivity, and tipping curves. The clean shaped optics, careful attention to feed design, and high sensitivity of the L band receiver (Trx 6 K) yield a system with high aperture efficiency ( 0.8), excellent sensitivity ( 9 m2/K), and low spillover ( 4 K). Observations of 21 cm atomic hydrogen lines towards standard sources demonstrate the low stray radiation pickup of the antenna. Ku band holography has measured the effective surface accuracy and stability of the dual-reflector antenna. The effective RMS of 0.85 mm implies a Ruze efficiency of 0.88 at 10 GHz and 0.60 at 20 GHz. The surface is stable ( 10% variation in surface RMS) over the limited range of environmental conditions tested. Testing continues for characterization of pointing, low frequency performance (< 1 GHz), and polarimetric performance. NRC is developing a successor antenna, DVA3, which will have a more accurate surface and be usable at frequencies at least up to Q band (30 - 50 GHz).

  18. Rayleigh-wave mode separation by high-resolution linear radon transform

    USGS Publications Warehouse

    Luo, Y.; Xia, J.; Miller, R.D.; Xu, Y.; Liu, J.; Liu, Q.

    2009-01-01

    Multichannel analysis of surface waves (MASW) method is an effective tool for obtaining vertical shear wave profiles from a single non-invasive measurement. One key step of the MASW method is generation of a dispersion image and extraction of a reliable dispersion curve from raw multichannel shot records. Because different Rayleigh-wave modes normally interfere with each other in the time and space domain, it is necessary to perform mode separation and reconstruction to increase the accuracy of phase velocities determined from a dispersion image. In this paper, we demonstrate the effectiveness of high-resolution linear Radon transform (LRT) as a means of separating and reconstructing multimode, dispersive Rayleigh-wave energy. We first introduce high-resolution LRT methods and Rayleigh-wave mode separation using high-resolution LRT. Next, we use synthetic data and a real-world example to demonstrate the effectiveness of Rayleigh-wave mode separation using high-resolution LRT. Our synthetic and real-world results demonstrate that (1) high-resolution LRT successfully separates and reconstructs multimode dispersive Rayleigh-wave energy with high resolution allowing the multimode energy to be more accurately determined. The horizontal resolution of the Rayleigh-wave method can be increased by extraction of dispersion curves from a pair of traces in the mode-separated shot gather and (2) multimode separation and reconstruction expand the usable frequency range of higher mode dispersive energy, which increases the depth of investigation and provides a means for accurately determining cut-off frequencies. ?? 2009 The Authors Journal compilation ?? 2009 RAS.

  19. Usability of a barcode scanning system as a means of data entry on a PDA for self-report health outcome questionnaires: a pilot study in individuals over 60 years of age

    PubMed Central

    Boissy, Patrick; Jacobs, Karen; Roy, Serge H

    2006-01-01

    Background Throughout the medical and paramedical professions, self-report health status questionnaires are used to gather patient-reported outcome measures. The objective of this pilot study was to evaluate in individuals over 60 years of age the usability of a PDA-based barcode scanning system with a text-to-speech synthesizer to collect data electronically from self-report health outcome questionnaires. Methods Usability of the system was tested on a sample of 24 community-living older adults (7 men, 17 women) ranging in age from 63 to 93 years. After receiving a brief demonstration on the use of the barcode scanner, participants were randomly assigned to complete two sets of 16 questions using the bar code wand scanner for one set and a pen for the other. Usability was assessed using directed interviews with a usability questionnaire and performance-based metrics (task times, errors, sources of errors). Results Overall, participants found barcode scanning easy to learn, easy to use, and pleasant. Participants were marginally faster in completing the 16 survey questions when using pen entry (20/24 participants). The mean response time with the barcode scanner was 31 seconds longer than traditional pen entry for a subset of 16 questions (p = 0.001). The responsiveness of the scanning system, expressed as first scan success rate, was less than perfect, with approximately one-third of first scans requiring a rescan to successfully capture the data entry. The responsiveness of the system can be explained by a combination of factors such as the location of the scanning errors, the type of barcode used as an answer field in the paper version, and the optical characteristics of the barcode scanner. Conclusion The results presented in this study offer insights regarding the feasibility, usability and effectiveness of using a barcode scanner with older adults as an electronic data entry method on a PDA. While participants in this study found their experience with the barcode scanning system enjoyable and learned to become proficient in its use, the responsiveness of the system constitutes a barrier to wide-scale use of such a system. Optimizing the graphical presentation of the information on paper should significantly increase the system's responsiveness. PMID:17184533

  20. Usability: Human Research Program - Space Human Factors and Habitability

    NASA Technical Reports Server (NTRS)

    Sandor, Aniko; Holden, Kritina L.

    2009-01-01

    The Usability project addresses the need for research in the area of metrics and methodologies used in hardware and software usability testing in order to define quantifiable and verifiable usability requirements. A usability test is a human-in-the-loop evaluation where a participant works through a realistic set of representative tasks using the hardware/software under investigation. The purpose of this research is to define metrics and methodologies for measuring and verifying usability in the aerospace domain in accordance with FY09 focus on errors, consistency, and mobility/maneuverability. Usability metrics must be predictive of success with the interfaces, must be easy to obtain and/or calculate, and must meet the intent of current Human Systems Integration Requirements (HSIR). Methodologies must work within the constraints of the aerospace domain, be cost and time efficient, and be able to be applied without extensive specialized training.

  1. A human reliability based usability evaluation method for safety-critical software

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boring, R. L.; Tran, T. Q.; Gertman, D. I.

    2006-07-01

    Boring and Gertman (2005) introduced a novel method that augments heuristic usability evaluation methods with that of the human reliability analysis method of SPAR-H. By assigning probabilistic modifiers to individual heuristics, it is possible to arrive at the usability error probability (UEP). Although this UEP is not a literal probability of error, it nonetheless provides a quantitative basis to heuristic evaluation. This method allows one to seamlessly prioritize and identify usability issues (i.e., a higher UEP requires more immediate fixes). However, the original version of this method required the usability evaluator to assign priority weights to the final UEP, thusmore » allowing the priority of a usability issue to differ among usability evaluators. The purpose of this paper is to explore an alternative approach to standardize the priority weighting of the UEP in an effort to improve the method's reliability. (authors)« less

  2. The North Carolina State University Libraries Search Experience: Usability Testing Tabbed Search Interfaces for Academic Libraries

    ERIC Educational Resources Information Center

    Teague-Rector, Susan; Ballard, Angela; Pauley, Susan K.

    2011-01-01

    Creating a learnable, effective, and user-friendly library Web site hinges on providing easy access to search. Designing a search interface for academic libraries can be particularly challenging given the complexity and range of searchable library collections, such as bibliographic databases, electronic journals, and article search silos. Library…

  3. Learning By Serving: 2,000 Ideas for Service-Learning Projects. Hot Topics: Usable Research.

    ERIC Educational Resources Information Center

    Follman, Joseph; And Others

    Defining service learning as the formal integration of public service into student instruction and learning, this guide provides teachers with ideas for narrowing the gap between what students do in school and what they will do after they leave school. The example activities, derived from actual projects, demonstrate the nearly limitless range of…

  4. A Cognitive Framework for Understanding Barriers to the Productive Use of a Diabetes Home Telemedicine System

    PubMed Central

    Kaufman, David R.; Starren, Justin; Patel, Vimla L.; Morin, Philip C.; Hilliman, Charlyn; Pevzner, Jenia; Weinstock, Ruth S.; Goland, Robin; Shea, Steven

    2003-01-01

    Telemedicine has the potential to transcend geographic and socio-cultural barriers to the delivery of high quality health care to the medically underserved populations. However, there are significant cognitive and usability barriers. This paper presents a multifaceted cognitive evaluation of the IDEATel diabetes education and telemedicine program. The evaluation included a cognitive walkthrough analysis to characterize task complexity and identify potential problems as well as field usability testing in patients’ homes. The study revealed dimensions of the interface that impeded optimal access to system resources. In addition, we found significant obstacles corresponding to perceptual-motoric skills, mental models of the system, and health literacy. The objective of this work is to contribute to a design framework so that participants with a wide range of skills can better manage their chronic illnesses. PMID:14728194

  5. Usability Evaluation of a Web-Based Learning System

    ERIC Educational Resources Information Center

    Nguyen, Thao

    2012-01-01

    The paper proposes a contingent, learner-centred usability evaluation method and a prototype tool of such systems. This is a new usability evaluation method for web-based learning systems using a set of empirically-supported usability factors and can be done effectively with limited resources. During the evaluation process, the method allows for…

  6. The Development of MSFC Usability Lab

    NASA Technical Reports Server (NTRS)

    Cheng, Yiwei; Richardson, Sally

    2010-01-01

    This conference poster reviews the development of the usability lab at Marshall Space Flight Center. The purpose of the lab was to integrate a fully functioning usability laboratory to provide a resource for future human factor assessments. and to implement preliminary usability testing on a MSFC website to validate the functionality of the lab.

  7. Understanding Usability: Investigating an Integrated Design Environment and Management System

    ERIC Educational Resources Information Center

    Lee, Jason Chong; Wahid, Shahtab; McCrickard, D. Scott; Chewar, C. M.; Congleton, Ben

    2007-01-01

    Purpose: Decades of innovation in designing usable (and unusable) interfaces have resulted in a plethora of guidelines, usability methods, and other design tools. The purpose of this research is to develop ways for novice developers to effectively leverage and contribute to the large and growing body of usability knowledge and methods.…

  8. Usability and Gratifications--Towards a Website Analysis Model.

    ERIC Educational Resources Information Center

    Bunz, Ulla K.

    This paper discusses Web site usability issues. Specifically, it assumes that the usability of a Web site depends more on the perception of the user than on the objectively assessable usability criteria of the Web site. Two pilot studies, based on theoretical notions of uses and gratifications theory and similar theories, are presented. In the…

  9. Integration of MSFC Usability Lab with Usability Testing

    NASA Technical Reports Server (NTRS)

    Cheng, Yiwei; Richardson, Sally

    2010-01-01

    As part of the Stage Analysis Branch, human factors engineering plays an important role in relating humans to the systems of hardware and structure designs of the new launch vehicle. While many branches are involved in the technical aspects of creating a launch vehicle, human factors connects humans to the scientific systems with the goal of improving operational performance and safety while reducing operational error and damage to the hardware. Human factors engineers use physical and computerized models to visualize possible areas for improvements to ensure human accessibility to components requiring maintenance and that the necessary maintenance activities can be accomplished with minimal risks to human and hardware. Many methods of testing are used to fulfill this goal, such as physical mockups, computerized visualization, and usability testing. In this analysis, a usability test is conducted to test how usable a website is to users who are and are not familiar with it. The testing is performed using participants and Morae software to record and analyze the results. This analysis will be a preliminary test of the usability lab in preparation for use in new spacecraft programs, NASA Enterprise, or other NASA websites. The usability lab project is divided into two parts: integration of the usability lab and a preliminary test of the usability lab.

  10. Design and validation of a questionnaire to evaluate the usability of computerized critical care information systems.

    PubMed

    von Dincklage, Falk; Lichtner, Gregor; Suchodolski, Klaudiusz; Ragaller, Maximilian; Friesdorf, Wolfgang; Podtschaske, Beatrice

    2017-08-01

    The implementation of computerized critical care information systems (CCIS) can improve the quality of clinical care and staff satisfaction, but also holds risks of disrupting the workflow with consecutive negative impacts. The usability of CCIS is one of the key factors determining their benefits and weaknesses. However, no tailored instrument exists to measure the usability of such systems. Therefore, the aim of this study was to design and validate a questionnaire that measures the usability of CCIS. Following a mixed-method design approach, we developed a questionnaire comprising two evaluation models to assess the usability of CCIS: (1) the task-specific model rates the usability individually for several tasks which CCIS could support and which we derived by analyzing work processes in the ICU; (2) the characteristic-specific model rates the different aspects of the usability, as defined by the international standard "ergonomics of human-system interaction". We tested validity and reliability of the digital version of the questionnaire in a sample population. In the sample population of 535 participants both usability evaluation models showed a strong correlation with the overall rating of the system (multiple correlation coefficients ≥0.80) as well as a very high internal consistency (Cronbach's alpha ≥0.93). The novel questionnaire is a valid and reliable instrument to measure the usability of CCIS and can be used to study the influence of the usability on their implementation benefits and weaknesses.

  11. Systematic Review Protocol to Assess the Effectiveness of Usability Questionnaires in mHealth App Studies.

    PubMed

    Zhou, Leming; Bao, Jie; Parmanto, Bambang

    2017-08-01

    Usability questionnaires have a wide use in mobile health (mHealth) app usability studies. However, no systematic review has been conducted for assessing the effectiveness of these questionnaires. This paper describes a protocol for conducting a systematic review of published questionnaire-based mHealth app usability studies. In this systematic review, we will select recently published (2008-2017) articles from peer-reviewed journals and conferences that describe mHealth app usability studies and implement at least one usability questionnaire. The search strategy will include terms such as "mobile app" and "usability." Multiple databases such as PubMed, CINAHL, IEEE Xplore, ACM Digital Library, and INSPEC will be searched. There will be 2 independent reviewers in charge of screening titles and abstracts as well as determining those articles that should be included for a full-text review. The third reviewer will act as a mediator between the other 2 reviewers. Moreover, a data extraction form will be created and used during the full article data analysis. Notably, the Preferred Reporting Items for Systematic Review and Meta-Analysis Protocols (PRISMA-P) guidelines will be followed in reporting this protocol. A preliminary search produced 1271 articles, 40 of which are duplicate records. The inclusion-exclusion criteria are being strictly followed in performing the ongoing study selection. Usability questionnaires are an important tool in mHealth app usability studies. This review will summarize the usability questionnaires used in published research articles while assessing the efficacy of these questionnaires in determining the usability of mHealth apps. ©Leming Zhou, Jie Bao, Bambang Parmanto. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 01.08.2017.

  12. Comparison of two heuristic evaluation methods for evaluating the usability of health information systems.

    PubMed

    Khajouei, Reza; Hajesmaeel Gohari, Sadrieh; Mirzaee, Moghaddameh

    2018-04-01

    In addition to following the usual Heuristic Evaluation (HE) method, the usability of health information systems can also be evaluated using a checklist. The objective of this study is to compare the performance of these two methods in identifying usability problems of health information systems. Eight evaluators independently evaluated different parts of a Medical Records Information System using two methods of HE (usual and with a checklist). The two methods were compared in terms of the number of problems identified, problem type, and the severity of identified problems. In all, 192 usability problems were identified by two methods in the Medical Records Information System. This was significantly higher than the number of usability problems identified by the checklist and usual method (148 and 92, respectively) (p < 0.0001). After removing the duplicates, the difference between the number of unique usability problems identified by the checklist method (n = 100) and usual method (n = 44) was significant (p < 0.0001). Differences between the mean severity of the real usability problems (1.83) and those identified by only one of the methods (usual = 2.05, checklist = 1.74) were significant (p = 0.001). This study revealed the potential of the two HE methods for identifying usability problems of health information systems. The results demonstrated that the checklist method had significantly better performance in terms of the number of identified usability problems; however, the performance of the usual method for identifying problems of higher severity was significantly better. Although the checklist method can be more efficient for less experienced evaluators, wherever usability is critical, the checklist should be used with caution in usability evaluations. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. A usability evaluation of a SNOMED CT based compositional interface terminology for intensive care.

    PubMed

    Bakhshi-Raiez, F; de Keizer, N F; Cornet, R; Dorrepaal, M; Dongelmans, D; Jaspers, M W M

    2012-05-01

    To evaluate the usability of a large compositional interface terminology based on SNOMED CT and the terminology application for registration of the reasons for intensive care admission in a Patient Data Management System. Observational study with user-based usability evaluations before and 3 months after the system was implemented and routinely used. Usability was defined by five aspects: effectiveness, efficiency, learnability, overall user satisfaction, and experienced usability problems. Qualitative (the Think-Aloud user testing method) and quantitative (the System Usability Scale questionnaire and Time-on-Task analyses) methods were used to examine these usability aspects. The results of the evaluation study revealed that the usability of the interface terminology fell short (SUS scores before and after implementation of 47.2 out of 100 and 37.5 respectively out of 100). The qualitative measurements revealed a high number (n=35) of distinct usability problems, leading to ineffective and inefficient registration of reasons for admission. The effectiveness and efficiency of the system did not change over time. About 14% (n=5) of the revealed usability problems were related to the terminology content based on SNOMED CT, while the remaining 86% (n=30) was related to the terminology application. The problems related to the terminology content were more severe than the problems related to the terminology application. This study provides a detailed insight into how clinicians interact with a controlled compositional terminology through a terminology application. The extensiveness, complexity of the hierarchy, and the language usage of an interface terminology are defining for its usability. Carefully crafted domain-specific subsets and a well-designed terminology application are needed to facilitate the use of a complex compositional interface terminology based on SNOMED CT. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  14. Usability Evaluation of Laboratory Information Systems.

    PubMed

    Mathews, Althea; Marc, David

    2017-01-01

    Numerous studies have revealed widespread clinician frustration with the usability of electronic health records (EHRs) that is counterproductive to adoption of EHR systems to meet the aims of health-care reform. With poor system usability comes increased risk of negative unintended consequences. Usability issues could lead to user error and workarounds that have the potential to compromise patient safety and negatively impact the quality of care.[1] While there is ample research on EHR usability, there is little information on the usability of laboratory information systems (LISs). Yet, LISs facilitate the timely provision of a great deal of the information needed by physicians to make patient care decisions.[2] Medical and technical advances in genomics that require processing of an increased volume of complex laboratory data further underscore the importance of developing user-friendly LISs. This study aims to add to the body of knowledge on LIS usability. A survey was distributed among LIS users at hospitals across the United States. The survey consisted of the ten-item System Usability Scale (SUS). In addition, participants were asked to rate the ease of performing 24 common tasks with a LIS. Finally, respondents provided comments on what they liked and disliked about using the LIS to provide diagnostic insight into LIS perceived usability. The overall mean SUS score of 59.7 for the LIS evaluated is significantly lower than the benchmark of 68 ( P < 0.001). All LISs evaluated received mean SUS scores below 68 except for Orchard Harvest (78.7). While the years of experience using the LIS was found to be a statistically significant influence on mean SUS scores, the combined effect of years of experience and LIS used did not account for the statistically significant difference in the mean SUS score between Orchard Harvest and each of the other LISs evaluated. The results of this study indicate that overall usability of LISs is poor. Usability lags that of systems evaluated across 446 usability surveys.

  15. Usability Evaluation of a Clinical Decision Support System for Geriatric ED Pain Treatment.

    PubMed

    Genes, Nicholas; Kim, Min Soon; Thum, Frederick L; Rivera, Laura; Beato, Rosemary; Song, Carolyn; Soriano, Jared; Kannry, Joseph; Baumlin, Kevin; Hwang, Ula

    2016-01-01

    Older adults are at risk for inadequate emergency department (ED) pain care. Unrelieved acute pain is associated with poor outcomes. Clinical decision support systems (CDSS) hold promise to improve patient care, but CDSS quality varies widely, particularly when usability evaluation is not employed. To conduct an iterative usability and redesign process of a novel geriatric abdominal pain care CDSS. We hypothesized this process would result in the creation of more usable and favorable pain care interventions. Thirteen emergency physicians familiar with the Electronic Health Record (EHR) in use at the study site were recruited. Over a 10-week period, 17 1-hour usability test sessions were conducted across 3 rounds of testing. Participants were given 3 patient scenarios and provided simulated clinical care using the EHR, while interacting with the CDSS interventions. Quantitative System Usability Scores (SUS), favorability scores and qualitative narrative feedback were collected for each session. Using a multi-step review process by an interdisciplinary team, positive and negative usability issues in effectiveness, efficiency, and satisfaction were considered, prioritized and incorporated in the iterative redesign process of the CDSS. Video analysis was used to determine the appropriateness of the CDS appearances during simulated clinical care. Over the 3 rounds of usability evaluations and subsequent redesign processes, mean SUS progressively improved from 74.8 to 81.2 to 88.9; mean favorability scores improved from 3.23 to 4.29 (1 worst, 5 best). Video analysis revealed that, in the course of the iterative redesign processes, rates of physicians' acknowledgment of CDS interventions increased, however most rates of desired actions by physicians (such as more frequent pain score updates) decreased. The iterative usability redesign process was instrumental in improving the usability of the CDSS; if implemented in practice, it could improve geriatric pain care. The usability evaluation process led to improved acknowledgement and favorability. Incorporating usability testing when designing CDSS interventions for studies may be effective to enhance clinician use.

  16. Translation, Cross-Cultural Adaptation, and Validation of the Malay Version of the System Usability Scale Questionnaire for the Assessment of Mobile Apps.

    PubMed

    Mohamad Marzuki, Muhamad Fadhil; Yaacob, Nor Azwany; Yaacob, Najib Majdi

    2018-05-14

    A mobile app is a programmed system designed to be used by a target user on a mobile device. The usability of such a system refers not only to the extent to which product can be used to achieve the task that it was designed for, but also its effectiveness and efficiency, as well as user satisfaction. The System Usability Scale is one of the most commonly used questionnaires used to assess the usability of a system. The original 10-item version of System Usability Scale was developed in English and thus needs to be adapted into local languages to assess the usability of a mobile apps developed in other languages. The aim of this study is to translate and validate (with cross-cultural adaptation) the English System Usability Scale questionnaire into Malay, the main language spoken in Malaysia. The development of a translated version will allow the usability of mobile apps to be assessed in Malay. Forward and backward translation of the questionnaire was conducted by groups of Malay native speakers who spoke English as their second language. The final version was obtained after reconciliation and cross-cultural adaptation. The content of the Malay System Usability Scale questionnaire for mobile apps was validated by 10 experts in mobile app development. The efficacy of the questionnaire was further probed by testing the face validity on 10 mobile phone users, followed by reliability testing involving 54 mobile phone users. The content validity index was determined to be 0.91, indicating good relevancy of the 10 items used to assess the usability of a mobile app. Calculation of the face validity index resulted in a value of 0.94, therefore indicating that the questionnaire was easily understood by the users. Reliability testing showed a Cronbach alpha value of .85 (95% CI 0.79-0.91) indicating that the translated System Usability Scale questionnaire is a reliable tool for the assessment of usability of a mobile app. The Malay System Usability Scale questionnaire is a valid and reliable tool to assess the usability of mobile app in Malaysia. ©Muhamad Fadhil Mohamad Marzuki, Nor Azwany Yaacob, Najib Majdi Yaacob. Originally published in JMIR Human Factors (http://humanfactors.jmir.org), 14.05.2018.

  17. Does the use of structured reporting improve usability? A comparative evaluation of the usability of two approaches for findings reporting in a large-scale telecardiology context.

    PubMed

    Lacerda, Thaisa Cardoso; von Wangenheim, Christiane Gresse; von Wangenheim, Aldo; Giuliano, Isabela

    2014-12-01

    One of the main reasons that leads to a low adoption rate of telemedicine systems is poor usability. An aspect that influences usability during the reporting of findings is the input mode, e.g., if a free-text (FT) or a structured report (SR) interface is employed. The objective of our study is to compare the usability of FT and ST telemedicine systems, specifically in terms of user satisfaction, efficiency and general usability. We comparatively evaluate the usability of these two input modes in a telecardiology system for issuing electrocardiography reports in the context of a statewide telemedicine system in Brazil with more than 350.000 performed tele-electrocardiography examinations. We adopted a multiple method research strategy, applying three different kinds of usability evaluations: user satisfaction was evaluated through interviews with seven medical professionals using the System Usability Scale (SUS) questionnaire and specific questions related to adequacy and user experience. Efficiency was evaluated by estimating execution time using the Keystroke-Level Model (KLM). General usability was assessed based on the conformity of the systems to a set of e-health specific usability heuristics. The results of this comparison provide a first indication that a structured report (SR) input mode for such a system is more satisfactory and efficient with a larger conformity to usability heuristics than free-text (FT) input. User satisfaction using the SUS questionnaire has been scored in average with 58.8 and 77.5 points for the FT and SR system, respectively, which means that the SR system was rated 18.65 points higher than the FT system. In terms of efficiency, the completion of a findings report using the SR mode is estimated to take 8.5s, 3.74 times faster than using the FT system (31.8s). The SR system also demonstrated less violations to usability heuristics (8 points) in comparison to 14 points observed in the FT system. These results provide a first indication that the usage of structured reporting as an input mode in telecardiology systems may enhance usability. This also seems to confirm the advantages of the usage of structured reporting, as already described in the literature for other areas such as teleradiology. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. The quality of information on the Internet on orthodontic retainer wear: a cross-sectional study.

    PubMed

    Doğramacı, Esma J; Rossi-Fedele, Giampiero

    2016-03-01

    The objectives of this study were to assess the accessibility, usability, reliability and quality of information on the Internet written for the lay public about orthodontic retainers, and to elucidate the different retention protocols encouraged. A cross-sectional, observational study. Online, using a computer connected to the Internet in Australia. Two search terms; 'orthodontic retainer' and 'how long should someone wear a retainer after their braces are removed?' were entered alternatively into five search engines. Twenty results for each search term per search engine that fulfilled the inclusion criteria were evaluated in terms of accessibility, usability, reliability and quality of information using the LIDA and DISCERN instruments, ensuring there were no internal or cross-search engine duplicates. Any information about frequency and duration of retainer wear was also collected. Two hundred different websites were identified and assessed. The median overall LIDA score was 72%, corresponding to a moderate quality level. The median total DISCERN score was 47%. Twenty-two websites recommended patients adhere to the specific protocol prescribed to them by their practitioner. There were 45 (22.5%) and 28 (14%) websites advising indefinite use of removable and bonded retainers respectively. Information about retainers on the Internet is easily accessible and usable, though the quality of the content is generally of a moderate level. However, the information is not always accurate and reliable. Both full-time and part-time wear of removable retainers was suggested over greatly varying time periods. Indefinite wear of removable and bonded retainers was also advocated.

  19. Spectral Entropy Based Neuronal Network Synchronization Analysis Based on Microelectrode Array Measurements

    PubMed Central

    Kapucu, Fikret E.; Välkki, Inkeri; Mikkonen, Jarno E.; Leone, Chiara; Lenk, Kerstin; Tanskanen, Jarno M. A.; Hyttinen, Jari A. K.

    2016-01-01

    Synchrony and asynchrony are essential aspects of the functioning of interconnected neuronal cells and networks. New information on neuronal synchronization can be expected to aid in understanding these systems. Synchronization provides insight in the functional connectivity and the spatial distribution of the information processing in the networks. Synchronization is generally studied with time domain analysis of neuronal events, or using direct frequency spectrum analysis, e.g., in specific frequency bands. However, these methods have their pitfalls. Thus, we have previously proposed a method to analyze temporal changes in the complexity of the frequency of signals originating from different network regions. The method is based on the correlation of time varying spectral entropies (SEs). SE assesses the regularity, or complexity, of a time series by quantifying the uniformity of the frequency spectrum distribution. It has been previously employed, e.g., in electroencephalogram analysis. Here, we revisit our correlated spectral entropy method (CorSE), providing evidence of its justification, usability, and benefits. Here, CorSE is assessed with simulations and in vitro microelectrode array (MEA) data. CorSE is first demonstrated with a specifically tailored toy simulation to illustrate how it can identify synchronized populations. To provide a form of validation, the method was tested with simulated data from integrate-and-fire model based computational neuronal networks. To demonstrate the analysis of real data, CorSE was applied on in vitro MEA data measured from rat cortical cell cultures, and the results were compared with three known event based synchronization measures. Finally, we show the usability by tracking the development of networks in dissociated mouse cortical cell cultures. The results show that temporal correlations in frequency spectrum distributions reflect the network relations of neuronal populations. In the simulated data, CorSE unraveled the synchronizations. With the real in vitro MEA data, CorSE produced biologically plausible results. Since CorSE analyses continuous data, it is not affected by possibly poor spike or other event detection quality. We conclude that CorSE can reveal neuronal network synchronization based on in vitro MEA field potential measurements. CorSE is expected to be equally applicable also in the analysis of corresponding in vivo and ex vivo data analysis. PMID:27803660

  20. A Serious Exergame for Patients Suffering from Chronic Musculoskeletal Back and Neck Pain: A Pilot Study

    PubMed Central

    Huis in ’t Veld, Rianne M.H.A.; Schönauer, Christian; Kaufmann, Hannes; Hermens, Hermie J.; Vollenbroek-Hutten, Miriam M.R.

    2013-01-01

    Abstract Introduction Over recent years, the popularity of videogames has gone beyond youth and gamers and is slowly entering the field of professional healthcare. Exergames are an attractive alternative to physical therapy. The primary aim of this pilot study was to explore the user experience (usability, satisfaction, level of motivation, and game experience) of the patient with the “PlayMancer” exergame. The secondary aim was to explore the progression of the performed motor skills (walking velocity, overhead reach ability, and cervical range of motion) and the clinical changes (to physical condition, disability, and pain intensity) in a group of patients with chronic musculoskeletal pain using an exergame for 4 weeks. Materials and Methods In the European PlayMancer project, an exergame for physical rehabilitation of chronic pain patients was developed. This exergame is controlled by relevant motions of the patient's body captured by a motion suit and several infrared cameras. In three different integrated minigames, the patient can train the following motor skills: Walking velocity, overhead reaching, and neck mobility. Results Ten patients participated in this study and completed the 4 weeks of gaming. Patients rated the usability of the exergames as good (score of 78.5 [standard deviation 9.7; range, 60.0–97.5]) on the System Usability Scale, and the game motivated all patients to perform their exercises. Patients enjoyed playing and were pleased with both the game environment and the game play. Overall, the patients made a progression in the examined motor skills during the minigames over the 4 weeks of gaming. Conclusions The “PlayMancer” exergame is a potential tool for achieving physical rehabilitation because it motivates patients to perform their exercises and as a result increases their motor skills and physical condition. PMID:24761327

  1. A Serious Exergame for Patients Suffering from Chronic Musculoskeletal Back and Neck Pain: A Pilot Study.

    PubMed

    Jansen-Kosterink, Stephanie M; Huis In 't Veld, Rianne M H A; Schönauer, Christian; Kaufmann, Hannes; Hermens, Hermie J; Vollenbroek-Hutten, Miriam M R

    2013-10-01

    Over recent years, the popularity of videogames has gone beyond youth and gamers and is slowly entering the field of professional healthcare. Exergames are an attractive alternative to physical therapy. The primary aim of this pilot study was to explore the user experience (usability, satisfaction, level of motivation, and game experience) of the patient with the "PlayMancer" exergame. The secondary aim was to explore the progression of the performed motor skills (walking velocity, overhead reach ability, and cervical range of motion) and the clinical changes (to physical condition, disability, and pain intensity) in a group of patients with chronic musculoskeletal pain using an exergame for 4 weeks. In the European PlayMancer project, an exergame for physical rehabilitation of chronic pain patients was developed. This exergame is controlled by relevant motions of the patient's body captured by a motion suit and several infrared cameras. In three different integrated minigames, the patient can train the following motor skills: Walking velocity, overhead reaching, and neck mobility. Ten patients participated in this study and completed the 4 weeks of gaming. Patients rated the usability of the exergames as good (score of 78.5 [standard deviation 9.7; range, 60.0-97.5]) on the System Usability Scale, and the game motivated all patients to perform their exercises. Patients enjoyed playing and were pleased with both the game environment and the game play. Overall, the patients made a progression in the examined motor skills during the minigames over the 4 weeks of gaming. The "PlayMancer" exergame is a potential tool for achieving physical rehabilitation because it motivates patients to perform their exercises and as a result increases their motor skills and physical condition.

  2. Less is more: development and evaluation of an interactive e-atlas to support anatomy learning.

    PubMed

    Guy, Richard; Pisani, Heather R; Rich, Peter; Leahy, Cathy; Mandarano, Giovanni; Molyneux, Tom

    2015-01-01

    An Interactive electronic Atlas (IeA) was developed to assist first-year nursing students with interpretation of laboratory-based prosected cadaveric material. It was designed, using pedagogically sound principles, as a student-centered resource accessible to students from a wide range of learning backgrounds. It consisted of a highly simplified interactive interface limited to essential anatomical structures and was intended for use in a blended learning situation. The IeA's nine modules mirrored the body systems covered in a Nursing Biosciences course, with each module comprising a maximum of 10 pages using the same template: an image displaying a cadaveric specimen and, in most cases, a corresponding anatomical model with navigation panes (menus) on one side. Cursor movement over the image or clicking the menu highlighted the structure with a transparent overlay and revealed a succinct functional description. The atlas was complemented by a multiple-choice database of nearly 1,000 questions using IeA images. Students' perceptions of usability and utility were measured by survey (n = 115; 57% of the class) revealing mean access of 2.3 times per week during the 12-week semester and a median time of three hours of use. Ratings for usability and utility were high, with means ranging between 4.24 and 4.54 (five-point Likert scale; 5 = strongly agree). Written responses told a similar story for both usability and utility. The role of providing basic computer-assisted learning support for a large first-year class is discussed in the context of current research into student-centered resources and blended learning in human anatomy. © 2014 American Association of Anatomists.

  3. Improving the Usability of the User Interface for a Digital Textbook Platform for Elementary-School Students

    ERIC Educational Resources Information Center

    Lim, Cheolil; Song, Hae-Deok; Lee, Yekyung

    2012-01-01

    Usability is critical to the development of a user-friendly digital textbook platform interface, yet thorough research on interface development based on usability principles is in short supply. This study addresses that need by looking at usability attributes and corresponding design elements from a learning perspective. The researchers used a…

  4. Using Cluster Analysis to Extend Usability Testing to Instructional Content. CRESST Report 816

    ERIC Educational Resources Information Center

    Kerr, Deirdre S.; Chung, Gregory K. W. K.

    2012-01-01

    Commercial video games undergo usability studies to determine the degree to which the player is able to learn, control, and understand the game. Usability studies allow game designers to improve their games before they are released to the public. If usability studies could be expanded to include information about the presentation of the…

  5. Usability Testing of a Multimedia e-Learning Resource for Electrolyte and Acid-Base Disorders

    ERIC Educational Resources Information Center

    Davids, Mogamat Razeen; Chikte, Usuf; Grimmer-Somers, Karen; Halperin, Mitchell L.

    2014-01-01

    The usability of computer interfaces may have a major influence on learning. Design approaches that optimize usability are commonplace in the software development industry but are seldom used in the development of e-learning resources, especially in medical education. We conducted a usability evaluation of a multimedia resource for teaching…

  6. Advocating for Greater Usability in Clinical Technologies: The Role of the Practicing Nurse.

    PubMed

    Lopez, Karen Dunn; Fahey, Linda

    2018-06-01

    Health care, especially ICUs, rely on multiple types of technology to promote the best patient outcomes. Unfortunately, too often these technologies are poorly designed, causing errors, additional workload, and unnecessary frustration. The purpose of this article is to (1) empower nurses with the needed usability and usability testing vocabulary to identify and articulate clinical technology usability problems and (2) provide ideas on ways nurses can advocate to have an impact on positive change related to technology usability within a health care organization. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. Development of a Video Coding Scheme for Analyzing the Usability and Usefulness of Health Information Systems.

    PubMed

    Kushniruk, Andre W; Borycki, Elizabeth M

    2015-01-01

    Usability has been identified as a key issue in health informatics. Worldwide numerous projects have been carried out in an attempt to increase and optimize health system usability. Usability testing, involving observing end users interacting with systems, has been widely applied and numerous publications have appeared describing such studies. However, to date, fewer works have been published describing methodological approaches to analyzing the rich data stream that results from usability testing. This includes analysis of video, audio and screen recordings. In this paper we describe our work in the development and application of a coding scheme for analyzing the usability of health information systems. The phases involved in such analyses are described.

  8. Patients and medical statistics. Interest, confidence, and ability.

    PubMed

    Woloshin, Steven; Schwartz, Lisa M; Welch, H Gilbert

    2005-11-01

    People are increasingly presented with medical statistics. There are no existing measures to assess their level of interest or confidence in using medical statistics. To develop 2 new measures, the STAT-interest and STAT-confidence scales, and assess their reliability and validity. Survey with retest after approximately 2 weeks. Two hundred and twenty-four people were recruited from advertisements in local newspapers, an outpatient clinic waiting area, and a hospital open house. We developed and revised 5 items on interest in medical statistics and 3 on confidence understanding statistics. Study participants were mostly college graduates (52%); 25% had a high school education or less. The mean age was 53 (range 20 to 84) years. Most paid attention to medical statistics (6% paid no attention). The mean (SD) STAT-interest score was 68 (17) and ranged from 15 to 100. Confidence in using statistics was also high: the mean (SD) STAT-confidence score was 65 (19) and ranged from 11 to 100. STAT-interest and STAT-confidence scores were moderately correlated (r=.36, P<.001). Both scales demonstrated good test-retest repeatability (r=.60, .62, respectively), internal consistency reliability (Cronbach's alpha=0.70 and 0.78), and usability (individual item nonresponse ranged from 0% to 1.3%). Scale scores correlated only weakly with scores on a medical data interpretation test (r=.15 and .26, respectively). The STAT-interest and STAT-confidence scales are usable and reliable. Interest and confidence were only weakly related to the ability to actually use data.

  9. Patients and Medical Statistics

    PubMed Central

    Woloshin, Steven; Schwartz, Lisa M; Welch, H Gilbert

    2005-01-01

    BACKGROUND People are increasingly presented with medical statistics. There are no existing measures to assess their level of interest or confidence in using medical statistics. OBJECTIVE To develop 2 new measures, the STAT-interest and STAT-confidence scales, and assess their reliability and validity. DESIGN Survey with retest after approximately 2 weeks. SUBJECTS Two hundred and twenty-four people were recruited from advertisements in local newspapers, an outpatient clinic waiting area, and a hospital open house. MEASURES We developed and revised 5 items on interest in medical statistics and 3 on confidence understanding statistics. RESULTS Study participants were mostly college graduates (52%); 25% had a high school education or less. The mean age was 53 (range 20 to 84) years. Most paid attention to medical statistics (6% paid no attention). The mean (SD) STAT-interest score was 68 (17) and ranged from 15 to 100. Confidence in using statistics was also high: the mean (SD) STAT-confidence score was 65 (19) and ranged from 11 to 100. STAT-interest and STAT-confidence scores were moderately correlated (r=.36, P<.001). Both scales demonstrated good test–retest repeatability (r=.60, .62, respectively), internal consistency reliability (Cronbach's α=0.70 and 0.78), and usability (individual item nonresponse ranged from 0% to 1.3%). Scale scores correlated only weakly with scores on a medical data interpretation test (r=.15 and .26, respectively). CONCLUSION The STAT-interest and STAT-confidence scales are usable and reliable. Interest and confidence were only weakly related to the ability to actually use data. PMID:16307623

  10. A review of principles in design and usability testing of tactile technology for individuals with visual impairments.

    PubMed

    Horton, Emily L; Renganathan, Ramkesh; Toth, Bryan N; Cohen, Alexa J; Bajcsy, Andrea V; Bateman, Amelia; Jennings, Mathew C; Khattar, Anish; Kuo, Ryan S; Lee, Felix A; Lim, Meilin K; Migasiuk, Laura W; Zhang, Amy; Zhao, Oliver K; Oliveira, Marcio A

    2017-01-01

    To lay the groundwork for devising, improving, and implementing new technologies to meet the needs of individuals with visual impairments, a systematic literature review was conducted to: a) describe hardware platforms used in assistive devices, b) identify their various applications, and c) summarize practices in user testing conducted with these devices. A search in relevant EBSCO databases for articles published between 1980 and 2014 with terminology related to visual impairment, technology, and tactile sensory adaptation yielded 62 articles that met the inclusion criteria for final review. It was found that while earlier hardware development focused on pin matrices, the emphasis then shifted toward force feedback haptics and accessible touch screens. The inclusion of interactive and multimodal features has become increasingly prevalent. The quantity and consistency of research on navigation, education, and computer accessibility suggest that these are pertinent areas of need for the visually impaired community. Methodologies for usability testing ranged from case studies to larger cross-sectional studies. Many studies used blindfolded sighted users to draw conclusions about design principles and usability. Altogether, the findings presented in this review provide insight on effective design strategies and user testing methodologies for future research on assistive technology for individuals with visual impairments.

  11. Usability in product development practice; an exploratory case study comparing four markets.

    PubMed

    van Kuijk, Jasper; van Driel, Liesbeth; van Eijk, Daan

    2015-03-01

    This study explored how usability was dealt with in four product development organizations active in different sectors: high-end automotive, professional printers and copiers, office coffee makers and fast moving consumer goods. The primary differentiators of the selected cases were whether they were targeting businesses or consumers and the degree of product complexity. Interviews with 19 product development practitioners were conducted, focussing on three topics: 1) the product development process and the integration of user involvement, 2) multidisciplinary teamwork, and 3) organizational attitude towards usability. Based on the interviews, context descriptions of the companies were created and barriers and enablers for usability were identified. To verify the findings and to discuss remaining issues a feedback workshop was held in which the primary contact from each company participated. The results indicate that differences in product-market combination lead to differences in organizational attitude towards usability. The prioritization of usability in an organization seems to be influenced by the degree of product complexity (complex products are more prone to suffer from usability issues) and whether developers think that usability is a purchase consideration for their clients. The product-market combination a company targets also affects the methods for user-centred design that a company can apply and that are relevant. What methods for user-centred design are used also seems to be influenced by the attitude towards usability: if usability is considered more important, methods that require more resources can be applied. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  12. Usability test of an internet-based informatics tool for diabetes care providers: the comprehensive diabetes management program.

    PubMed

    Fonda, Stephanie J; Paulsen, Christine A; Perkins, Joan; Kedziora, Richard J; Rodbard, David; Bursell, Sven-Erik

    2008-02-01

    Research suggests Internet-based care management tools are associated with improvements in care and patient outcomes. However, although such tools change workflow, rarely is their usability addressed and reported. This article presents a usability study of an Internet-based informatics application called the Comprehensive Diabetes Management Program (CDMP), developed by content experts and technologists. Our aim is to demonstrate a process for conducting a usability study of such a tool and to report results. We conducted the usability test with six diabetes care providers under controlled conditions. Each provider worked with the CDMP in a single session using a "think aloud" process. Providers performed standardized tasks with fictitious patient data, and we observed how they approached these tasks, documenting verbalizations and subjective ratings. The providers then completed a usability questionnaire and interviews. Overall, the scores on the usability questionnaire were neutral to favorable. For specific subdomains of the questionnaire, the providers' reported problems with the application's ease of use, performance, and support features, but were satisfied with its visual appeal and content. The results from the observational and interview data indicated areas for improvement, particularly in navigation and terminology. The usability study identified several issues for improvement, confirming the need for usability testing of Internet-based informatics applications, even those developed by experts. To our knowledge, there have been no other usability studies of an Internet-based informatics application with the functionality of the CDMP. Such studies can form the foundation for translation of Internet-based medical informatics tools into clinical practice.

  13. Usability Evaluation of An Electronic Medication Administration Record (eMAR) Application

    PubMed Central

    Guo, J.; Iribarren, S.; Kapsandoy, S.; Perri, S.; Staggers, N.

    2011-01-01

    Background Electronic medication administration records (eMARs) have been widely used in recent years. However, formal usability evaluations are not yet available for these vendor applications, especially from the perspective of nurses, the largest group of eMAR users. Objective To conduct a formal usability evaluation of an implemented eMAR. Methods Four evaluators examined a commercial vendor eMAR using heuristic evaluation techniques. The evaluators defined seven tasks typical of eMAR use and independently evaluated the application. Consensus techniques were used to obtain 100% agreement of identified usability problems and severity ratings. Findings were reviewed with 5 clinical staff nurses and the Director of Clinical Informatics who verified findings with a small group of clinical nurses. Results Evaluators found 60 usability problems categorized into 233 heuristic violations. Match, Error, and Visibility heuristics were the most frequently violated. Administer Medication and Order and Modify Medications tasks had the highest number of heuristic violations and usability problems rated as major or catastrophic. Conclusion The high number of usability problems could impact the effectiveness, efficiency and satisfaction of nurses’ medication administration activities and may include concerns about patient safety. Usability is a joint responsibility between sites and vendors. We offer a call to action for usability evaluations at all sites and eMAR application redesign as necessary to improve the user experience and promote patient safety. PMID:23616871

  14. Reusable Software Usability Specifications for mHealth Applications.

    PubMed

    Cruz Zapata, Belén; Fernández-Alemán, José Luis; Toval, Ambrosio; Idri, Ali

    2018-01-25

    One of the key factors for the adoption of mobile technologies, and in particular of mobile health applications, is usability. A usable application will be easier to use and understand by users, and will improve user's interaction with it. This paper proposes a software requirements catalog for usable mobile health applications, which can be used for the development of new applications, or the evaluation of existing ones. The catalog is based on the main identified sources in literature on usability and mobile health applications. Our catalog was organized according to the ISO/IEC/IEEE 29148:2011 standard and follows the SIREN methodology to create reusable catalogs. The applicability of the catalog was verified by the creation of an audit method, which was used to perform the evaluation of a real app, S Health, application created by Samsung Electronics Co. The usability requirements catalog, along with the audit method, identified several usability flaws on the evaluated app, which scored 83%. Some flaws were detected in the app related to the navigation pattern. Some more issues related to the startup experience, empty screens or writing style were also found. The way a user navigates through an application improves or deteriorates user's experience with the application. We proposed a reusable usability catalog and an audit method. This proposal was used to evaluate a mobile health application. An audit report was created with the usability issues identified on the evaluated application.

  15. Low-Cost Rapid Usability Testing: Its Application in Both Product Development and System Implementation.

    PubMed

    Kushniruk, Andre; Borycki, Elizabeth

    2017-01-01

    In recent years there has been considerable discussion around the need for certification and regulation of healthcare information technology (IT). In particular, the usability of the products being developed needs to be evaluated. This has included the application of standards designed to ensure the process of system development is user-centered and takes usability into consideration while a product is being developed. In addition to this, in healthcare, organizations in the United States and Europe have also addressed the need and requirement for product certification. However, despite these efforts there are continued reports of unusable and unsafe implementations. In this paper we discuss the need to not only include (and require) usability testing in the one-time development process of health IT products (such as EHRs), but we also argue for the need to additionally develop specific usability standards and requirements for usability testing during the implementation of vendor products (i.e. post product development) in healthcare settings. It is further argued that health IT products that may have been certified regarding their development process will still require application of usability testing in the process of implementing them in real hospital settings in order to ensure usability and safety. This is needed in order to ensure that the final result of both product development and implementation processes take into account and apply the latest usability principles and methods.

  16. Using a fuzzy comprehensive evaluation method to determine product usability: A proposed theoretical framework.

    PubMed

    Zhou, Ronggang; Chan, Alan H S

    2017-01-01

    In order to compare existing usability data to ideal goals or to that for other products, usability practitioners have tried to develop a framework for deriving an integrated metric. However, most current usability methods with this aim rely heavily on human judgment about the various attributes of a product, but often fail to take into account of the inherent uncertainties in these judgments in the evaluation process. This paper presents a universal method of usability evaluation by combining the analytic hierarchical process (AHP) and the fuzzy evaluation method. By integrating multiple sources of uncertain information during product usability evaluation, the method proposed here aims to derive an index that is structured hierarchically in terms of the three usability components of effectiveness, efficiency, and user satisfaction of a product. With consideration of the theoretical basis of fuzzy evaluation, a two-layer comprehensive evaluation index was first constructed. After the membership functions were determined by an expert panel, the evaluation appraisals were computed by using the fuzzy comprehensive evaluation technique model to characterize fuzzy human judgments. Then with the use of AHP, the weights of usability components were elicited from these experts. Compared to traditional usability evaluation methods, the major strength of the fuzzy method is that it captures the fuzziness and uncertainties in human judgments and provides an integrated framework that combines the vague judgments from multiple stages of a product evaluation process.

  17. Determining the Number of Participants Needed for the Usability Evaluation of E-Learning Resources: A Monte Carlo Simulation

    ERIC Educational Resources Information Center

    Davids, Mogamat Razeen; Harvey, Justin; Halperin, Mitchell L.; Chikte, Usuf M. E.

    2015-01-01

    The usability of computer interfaces has a major influence on learning. Optimising the usability of e-learning resources is therefore essential. However, this may be neglected because of time and monetary constraints. User testing is a common approach to usability evaluation and involves studying typical end-users interacting with the application…

  18. Better bioinformatics through usability analysis.

    PubMed

    Bolchini, Davide; Finkelstein, Anthony; Perrone, Vito; Nagl, Sylvia

    2009-02-01

    Improving the usability of bioinformatics resources enables researchers to find, interact with, share, compare and manipulate important information more effectively and efficiently. It thus enables researchers to gain improved insights into biological processes with the potential, ultimately, of yielding new scientific results. Usability 'barriers' can pose significant obstacles to a satisfactory user experience and force researchers to spend unnecessary time and effort to complete their tasks. The number of online biological databases available is growing and there is an expanding community of diverse users. In this context there is an increasing need to ensure the highest standards of usability. Using 'state-of-the-art' usability evaluation methods, we have identified and characterized a sample of usability issues potentially relevant to web bioinformatics resources, in general. These specifically concern the design of the navigation and search mechanisms available to the user. The usability issues we have discovered in our substantial case studies are undermining the ability of users to find the information they need in their daily research activities. In addition to characterizing these issues, specific recommendations for improvements are proposed leveraging proven practices from web and usability engineering. The methods and approach we exemplify can be readily adopted by the developers of bioinformatics resources.

  19. Evaluating User Perceptions of Mobile Medication Management Applications With Older Adults: A Usability Study

    PubMed Central

    Gates, Allison

    2014-01-01

    Background Medication nonadherence has a significant impact on the health and wellbeing of individuals with chronic disease. Several mobile medication management applications are available to help users track, remember, and read about their medication therapy. Objective The objective of this study was to explore the usability and usefulness of existing medication management applications for older adults. Methods We recruited 35 participants aged 50 and over to participate in a 2-hour usability session. The average age ranged from 52-78 years (mean 67 years) and 71% (25/35) of participants were female. Each participant was provided with an iPad loaded with four medication management applications: MyMedRec, DrugHub, Pillboxie, and PocketPharmacist. These applications were evaluated using the 10 item System Usability Scale (SUS) and visual analog scale. An investigator-moderated 30-minute discussion followed, and was recorded. We used a grounded theory (GT) approach to analyze qualitative data. Results When assessing mobile medication management applications, participants struggled to think of a need for the applications in their own lives. Many were satisfied with their current management system and proposed future use only if cognition and health declined. Most participants felt capable of using the applications after a period of time and training, but were frustrated by their initial experiences with the applications. The early experiences of participants highlighted the benefits of linear navigation and clear wording (eg, “undo” vs “cancel”) when designing for older users. While there was no order effect, participants attributed their poor performance to the order in which they tried the applications. They also described being a part of a technology generation that did not encounter the computer until adulthood. Of the four applications, PocketPharmacist was found to be the least usable with a score of 42/100 (P<.0001) though it offered a drug interaction feature that was among the favorite features of participants. The usability scores for MyMedRec (56/100), DrugHub (57/100), and Pillboxie (52/100) were not significantly different and participants preferred MyMedRec and DrugHub for their simple, linear interfaces. Conclusions With training, adults aged 50 and over can be capable and interested in using mHealth applications for their medication management. However, in order to adopt such technology, they must find a need that their current medication management system cannot fill. Interface diversity and multimodal reminder methods should be considered to increase usability for older adults. Lastly, regulation or the involvement of older adults in development may help to alleviate generation bias and mistrust for applications. PMID:25099993

  20. Current State of Agile User-Centered Design: A Survey

    NASA Astrophysics Data System (ADS)

    Hussain, Zahid; Slany, Wolfgang; Holzinger, Andreas

    Agile software development methods are quite popular nowadays and are being adopted at an increasing rate in the industry every year. However, these methods are still lacking usability awareness in their development lifecycle, and the integration of usability/User-Centered Design (UCD) into agile methods is not adequately addressed. This paper presents the preliminary results of a recently conducted online survey regarding the current state of the integration of agile methods and usability/UCD. A world wide response of 92 practitioners was received. The results show that the majority of practitioners perceive that the integration of agile methods with usability/UCD has added value to their adopted processes and to their teams; has resulted in the improvement of usability and quality of the product developed; and has increased the satisfaction of the end-users of the product developed. The top most used HCI techniques are low-fidelity prototyping, conceptual designs, observational studies of users, usability expert evaluations, field studies, personas, rapid iterative testing, and laboratory usability testing.

  1. Hello World! - Experiencing Usability Methods without Usability Expertise

    NASA Astrophysics Data System (ADS)

    Eriksson, Elina; Cajander, Åsa; Gulliksen, Jan

    How do you do usability work when no usability expertise is available? What happens in an organization when system developers, with no previous HCI knowledge, after a 3-day course, start applying usability methods, and particularly field studies? In order to answer these questions qualitative data were gathered through participatory observations, a feed back survey, field study documentation and interviews from 47 system developers from a public authority. Our results suggest that field studies enhance the developer’s understanding of the user perspective, and provide a more holistic overview of the use situation, but that some developers were unable to interpret their observations and see solutions to the users’ problems. The field study method was very much appreciated and has now become standard operating procedure within the organization. However, although field studies may be useful, it does not replace the need for usability pro fes sion als, as their knowledge is essential for more complex observations, analysis and for keeping the focus on usability.

  2. The use of think-aloud and instant data analysis in evaluation research: Exemplar and lessons learned.

    PubMed

    Joe, Jonathan; Chaudhuri, Shomir; Le, Thai; Thompson, Hilaire; Demiris, George

    2015-08-01

    While health information technologies have become increasingly popular, many have not been formally tested to ascertain their usability. Traditional rigorous methods take significant amounts of time and manpower to evaluate the usability of a system. In this paper, we evaluate the use of instant data analysis (IDA) as developed by Kjeldskov et al. to perform usability testing on a tool designed for older adults and caregivers. The IDA method is attractive because it takes significantly less time and manpower than the traditional usability testing methods. In this paper we demonstrate how IDA was used to evaluate usability of a multifunctional wellness tool, discuss study results and lessons learned while using this method. We also present findings from an extension of the method which allows the grouping of similar usability problems in an efficient manner. We found that the IDA method is a quick, relatively easy approach to identifying and ranking usability issues among health information technologies. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. A Comparison of What Is Part of Usability Testing in Three Countries

    NASA Astrophysics Data System (ADS)

    Clemmensen, Torkil

    The cultural diversity of users of technology challenges our methods for usability evaluation. In this paper we report and compare three ethnographic interview studies of what is a part of a standard (typical) usability test in a company in Mumbai, Beijing and Copenhagen. At each of these three locations, we use structural and contrast questions do a taxonomic and paradigm analysis of a how a company performs a usability test. We find similar parts across the three locations. We also find different results for each location. In Mumbai, most parts of the usability test are not related to the interactive application that is tested, but to differences in user characteristics, test preparation, method, and location. In Copenhagen, considerations about the client's needs are part of a usability test. In Beijing, the only varying factor is the communication pattern and relation to the user. These results are then contrasted in a cross cultural matrix to identify cultural themes that can help interpret results from existing laboratory research in usability test methods.

  4. Usability Evaluation of a Private Social Network on Mental Health for Relatives.

    PubMed

    Toribio-Guzmán, José Miguel; García-Holgado, Alicia; Soto Pérez, Felipe; García-Peñalvo, Francisco J; Franco Martín, Manuel

    2017-09-01

    Usability is one of the most prominent criteria that must be fulfilled by a software product. This study aims to evaluate the usability of SocialNet, a private social network for monitoring the daily progress of patients by their relatives, using a mixed usability approach: heuristic evaluation conducted by experts and user testing. A double heuristic evaluation with one expert evaluator identified the issues related to consistency, design, and privacy. User testing was conducted on 20 users and one evaluator using observation techniques and questionnaires. The main usability problems were found to be related to the structure of SocialNet, and the users presented some difficulties in locating the buttons or links. The results show a high level of usability and satisfaction with the product. This evaluation provides data on the usability of SocialNet based on the difficulties experienced by the users and the expert. The results help in redesigning the tool to resolve the identified problems as part of an iterative process.

  5. Getting a Technology-based Diabetes Intervention Ready for Primetime: A Review of Usability Testing Studies

    PubMed Central

    Lyles, Courtney R.; Sarkar, Urmimala; Osborn, Chandra Y.

    2014-01-01

    Consumer health technologies can educate patients about diabetes and support their self-management, yet usability evidence is rarely published even though it determines patient engagement, optimal benefit of any intervention, and an understanding of generalizability. Therefore, we conducted a narrative review of peer-reviewed articles published from 2009–2013 that tested the usability of a web- or mobile-delivered system/application designed to educate and support patients with diabetes. Overall, the 23 papers included in our review used mixed (n=11), descriptive quantitative (n=9), and qualitative methods (n=3) to assess usability, such as documenting which features performed as intended and how patients rated their experiences. More sophisticated usability evaluations combined several complementary approaches to elucidate more aspects of functionality. Future work pertaining to the design and evaluation of technology-delivered diabetes education/support interventions should aim to standardize the usability testing processes, and publish usability findings to inform interpretation of why an intervention succeeded or failed, and for whom. PMID:25173689

  6. Usability evaluation of Laboratory and Radiology Information Systems integrated into a hospital information system.

    PubMed

    Nabovati, Ehsan; Vakili-Arki, Hasan; Eslami, Saeid; Khajouei, Reza

    2014-04-01

    This study was conducted to evaluate the usability of widely used laboratory and radiology information systems. Three usability experts independently evaluated the user interfaces of Laboratory and Radiology Information Systems using heuristic evaluation method. They applied Nielsen's heuristics to identify and classify usability problems and Nielsen's severity rating to judge their severity. Overall, 116 unique heuristic violations were identified as usability problems. In terms of severity, 67 % of problems were rated as major and catastrophic. Among 10 heuristics, "consistency and standards" was violated most frequently. Moreover, mean severity of problems concerning "error prevention" and "help and documentation" heuristics was higher than of the others. Despite widespread use of specific healthcare information systems, they suffer from usability problems. Improving the usability of systems by following existing design standards and principles from the early phased of system development life cycle is recommended. Especially, it is recommended that the designers design systems that inhibit the initiation of erroneous actions and provide sufficient guidance to users.

  7. End-Users' Voice in EHR Selection: Development of a Usability Questionnaire for Demonstrations in Procurement (DPUQ).

    PubMed

    Tyllinen, Mari; Kaipio, Johanna; Lääveri, Tinja; Nieminen, Marko

    2017-01-01

    This paper describes the development of a questionnaire for evaluating usability during EHR system procurement (DPUQ). Established usability questionnaires can be used to gather user feedback after using the systems. However, during procurement, experimenting with real system use is practical only with a limited number of system candidates. There is a need for less resource-demanding usability evaluation in the early stages of procurement in cases with several vendors. DPUQ has been designed for usability evaluation by end-users during special scenario-based vendor demonstrations. The questionnaire includes three sets of questions to be used during and after the vendor demonstration. DPUQ delivers specific usability scores and can be used to compare system candidates in procurement complementing other evaluation methods.

  8. Design for Usability; practice-oriented research for user-centered product design.

    PubMed

    van Eijk, Daan; van Kuijk, Jasper; Hoolhorst, Frederik; Kim, Chajoong; Harkema, Christelle; Dorrestijn, Steven

    2012-01-01

    The Design for Usability project aims at improving the usability of electronic professional and consumer products by creating new methodology and methods for user-centred product development, which are feasible to apply in practice. The project was focused on 5 key areas: (i) design methodology, expanding the existing approach of scenario-based design to incorporate the interaction between product design, user characteristics, and user behaviour; (ii) company processes, barriers and enablers for usability in practice; (iii) user characteristics in relation to types of products and use-situations; (iv) usability decision-making; and (v) product impact on user behaviour. The project team developed methods and techniques in each of these areas to support the design of products with a high level of usability. This paper brings together and summarizes the findings.

  9. Sony PlayStation EyeToy elicits higher levels of movement than the Nintendo Wii: implications for stroke rehabilitation.

    PubMed

    Neil, A; Ens, S; Pelletier, R; Jarus, T; Rand, D

    2013-02-01

    Virtual reality (VR) is an emerging trend in stroke rehabilitation. VR gaming consoles in stroke intervention have been shown to increase motivation and enjoyment during exercise. The amount and intensity of movements elicited using these consoles are unknown. The aims of this study were: (1) to quantify the amount and intensity of movement elicited from both hands of two groups of individuals ([chronic stroke and without a disability [healthy]); (2) to determine the effect of console (Wii/EyeToy) and group (stroke/healthy) on the amount and intensity of upper extremity movement; (3) to determine the effect of console (Wii/EyeToy) and group (stroke/healthy) on the usability and VR experience. A cross-sectional design was taken. Outpatient rehabilitation setting and healthy participant's homes. Participants included ten adults with stroke and ten adults without a disability. Participants experienced two games from each console. Amount and intensity of movement was measured using accelerometers on both wrists, while the virtual experience and usability was determined with questionnaires. No significant differences were found between the consoles usability and experience. EyeToy elicited significantly greater activity count than Wii among the healthy participants (P=0.028) and significantly greater movement intensity in both the stroke (P=0.005) and healthy (P=0.005) groups. Both consoles rated high for usability, enjoyment and satisfaction highlighting their suitability for a range of individuals in stroke rehabilitation. EyeToy provides increased movement and movement intensity. Both consoles are suitable for use in stroke rehabilitation however this information can be helpful to clinicians while selecting a gaming console according to the type and intensity of movements that he/she aims to encourage during therapy.

  10. Enabling the Usability of Earth Science Data Products and Services by Evaluating, Describing, and Improving Data Quality throughout the Data Lifecycle

    NASA Astrophysics Data System (ADS)

    Downs, R. R.; Peng, G.; Wei, Y.; Ramapriyan, H.; Moroni, D. F.

    2015-12-01

    Earth science data products and services are being used by representatives of various science and social science disciplines, by planning and decision-making professionals, by educators and learners ranging from primary through graduate and informal education, and by the general public. The diversity of users and uses of Earth science data is gratifying and offers new challenges for enabling the usability of these data by audiences with various purposes and levels of expertise. Users and other stakeholders need capabilities to efficiently find, explore, select, and determine the applicability and suitability of data products and services to meet their objectives and information needs. Similarly, they need to be able to understand the limitations of Earth science data, which can be complex, especially when considering combined or simultaneous use of multiple data products and services. Quality control efforts of stakeholders, throughout the data lifecycle, can contribute to the usability of Earth science data to meet the needs of diverse users. Such stakeholders include study design teams, data producers, data managers and curators, archives, systems professionals, data distributors, end-users, intermediaries, sponsoring organizations, hosting institutions, and others. Opportunities for engaging stakeholders to review, describe, and improve the quality of Earth science data products and services throughout the data lifecycle are identified and discussed. Insight is shared from the development of guidelines for implementing the Group on Earth Observations (GEO) Data Management Principles, the recommendations from the Earth Science Data System Working Group (ESDSWG) on Data Quality, and the efforts of the Information Quality Cluster of the Federation of Earth Science Information Partners (ESIP). Examples and outcomes from quality control efforts of data facilities, such as scientific data centers, that contribute to the usability of Earth science data also are offered.

  11. A Framework for Usability Evaluation in EHR Procurement.

    PubMed

    Tyllinen, Mari; Kaipio, Johanna; Lääveri, Tinja

    2018-01-01

    Usability should be considered already by the procuring organizations when selecting future systems. In this paper, we present a framework for usability evaluation during electronic health record (EHR) system procurement. We describe the objectives of the evaluation, the procedure, selected usability attributes and the evaluation methods to measure them. We also present the emphasis usability had in the selection process. We do not elaborate on the details of the results, the application of methods or gathering of data. Instead we focus on the components of the framework to inform and give an example to other similar procurement projects.

  12. A Guided Online and Mobile Self-Help Program for Individuals With Eating Disorders: An Iterative Engagement and Usability Study.

    PubMed

    Nitsch, Martina; Dimopoulos, Christina N; Flaschberger, Edith; Saffran, Kristina; Kruger, Jenna F; Garlock, Lindsay; Wilfley, Denise E; Taylor, Craig B; Jones, Megan

    2016-01-11

    Numerous digital health interventions have been developed for mental health promotion and intervention, including eating disorders. Efficacy of many interventions has been evaluated, yet knowledge about reasons for dropout and poor adherence is scarce. Most digital health intervention studies lack appropriate research design and methods to investigate individual engagement issues. User engagement and program usability are inextricably linked, making usability studies vital in understanding and improving engagement. The aim of this study was to explore engagement and corresponding usability issues of the Healthy Body Image Program-a guided online intervention for individuals with body image concerns or eating disorders. The secondary aim was to demonstrate the value of usability research in order to investigate engagement. We conducted an iterative usability study based on a mixed-methods approach, combining cognitive and semistructured interviews as well as questionnaires, prior to program launch. Two separate rounds of usability studies were completed, testing a total of 9 potential users. Thematic analysis and descriptive statistics were used to analyze the think-aloud tasks, interviews, and questionnaires. Participants were satisfied with the overall usability of the program. The average usability score was 77.5/100 for the first test round and improved to 83.1/100 after applying modifications for the second iteration. The analysis of the qualitative data revealed five central themes: layout, navigation, content, support, and engagement conditions. The first three themes highlight usability aspects of the program, while the latter two highlight engagement issues. An easy-to-use format, clear wording, the nature of guidance, and opportunity for interactivity were important issues related to usability. The coach support, time investment, and severity of users' symptoms, the program's features and effectiveness, trust, anonymity, and affordability were relevant to engagement. This study identified salient usability and engagement features associated with participant motivation to use the Healthy Body Image Program and ultimately helped improve the program prior to its implementation. This research demonstrates that improvements in usability and engagement can be achieved by testing and adjusting intervention design and content prior to program launch. The results are consistent with related research and reinforce the need for further research to identify usage patterns and effective means for reducing dropout. Digital health research should include usability studies prior to efficacy trials to help create more user-friendly programs that have a higher likelihood of "real-world" adoption.

  13. Workforce Issues. Employment Practices in Selected Large Private Companies. Report to Congressional Committees.

    ERIC Educational Resources Information Center

    General Accounting Office, Washington, DC. General Government Div.

    The General Accounting Office examined employment practices in 130 selected large private U.S. companies with at least 100 workers in each of 10 or more employment locations and at least 25,000 employees. Of the 130 companies surveyed, 83 (64%) returned usable responses. The respondents reported using a wide range of employment practices for…

  14. Analysis of E-Mail Produced by Middle School Students with Disabilities Using Accessible Interfaces: An Exploratory Study

    ERIC Educational Resources Information Center

    Sohlberg, McKay Moore; Todis, Bonnie; Fickas, Stephen; Ehlhardt, Laurie

    2011-01-01

    The goal of this exploratory study was to investigate electronic communication as a potential method to enhance social communication in a range of students with disabilities. This study investigated the usability of an adapted e-mail interface, TeenMail, for 11 middle school students with significant learning and communication impairments who…

  15. Propagation effects handbook for satellite systems design. A summary of propagation impairments on 10 to 100 GHz satellite links with techniques for system design

    NASA Technical Reports Server (NTRS)

    Ippolito, L. J.; Kaul, R. D.; Wallace, R. G.

    1983-01-01

    This Propagation Handbook provides satellite system engineers with a concise summary of the major propagation effects experienced on Earth-space paths in the 10 to 100 GHz frequency range. The dominant effect, attenuation due to rain, is dealt with in some detail, in terms of both experimental data from measurements made in the U.S. and Canada, and the mathematical and conceptual models devised to explain the data. In order to make the Handbook readily usable to many engineers, it has been arranged in two parts. Chapters 2-5 comprise the descriptive part. They deal in some detail with rain systems, rain and attenuation models, depolarization and experimental data. Chapters 6 and 7 make up the design part of the Handbook and may be used almost independently of the earlier chapters. In Chapter 6, the design techniques recommended for predicting propagation effects in Earth-space communications systems are presented. Chapter 7 addresses the questions of where in the system design process the effects of propagation should be considered, and what precautions should be taken when applying the propagation results.

  16. Low-noise kinetic inductance traveling-wave amplifier using three-wave mixing

    NASA Astrophysics Data System (ADS)

    Vissers, M. R.; Erickson, R. P.; Ku, H.-S.; Vale, Leila; Wu, Xian; Hilton, G. C.; Pappas, D. P.

    2016-01-01

    We have fabricated a wide-bandwidth, high dynamic range, low-noise cryogenic amplifier based on a superconducting kinetic inductance traveling-wave device. The device was made from NbTiN and consisted of a long, coplanar waveguide on a silicon chip. By adding a DC current and an RF pump tone, we are able to generate parametric amplification using three-wave mixing (3WM). The devices exhibit gain of more than 15 dB across an instantaneous bandwidth from 4 to 8 GHz. The total usable gain bandwidth, including both sides of the signal-idler gain region, is more than 6 GHz. The noise referred to the input of the devices approaches the quantum limit, with less than 1 photon excess noise. We compare these results directly to the four-wave mixing amplification mode, i.e., without DC-biasing. We find that the 3WM mode allows operation with the pump at lower RF power and at frequencies far from the signal. We have used this knowledge to redesign the amplifiers to utilize primarily 3WM amplification, thereby allowing for direct integration into large scale qubit and detector applications.

  17. A French crop-exposure matrix for use in epidemiological studies on pesticides: PESTIMAT.

    PubMed

    Baldi, Isabelle; Carles, Camille; Blanc-Lapierre, Audrey; Fabbro-Peray, Pascale; Druet-Cabanac, Michel; Boutet-Robinet, Elisa; Soulat, Jean-Marc; Bouvier, Ghislaine; Lebailly, Pierre

    2017-01-01

    Pesticide exposure assessment is a key methodological issue for epidemiological studies. The history of pesticide has proven difficult to obtain from individuals' report because of the wide range of active ingredients (AIs). We developed a crop-exposure matrix, which intends to reconstitute parameters of pesticide exposure in France since 1950. PESTIMAT is composed of tables crossing crops and AIs by year and providing the following metrics: (1) probability (proportion of farmers having used the AIs); (2) frequency (number of treatment days); and (3) intensity (application rate of the AIs in kg/ha). Metrics were obtained by the combination of six sources: (i) registration information from the Agriculture Ministry; (ii) information from agricultural bodies on products marketed; (iii) agricultural recommendations by the Plant Health Protection body; (iv) treatment calendars provided by farmers; (v) data from associations of farmers; and (vi) data from the industry. To date, 529 AIs usable between 1950 and 2010 are included in PESTIMAT: 160 fungicides; 160 herbicides; and 209 insecticides. When combined with duration and determinants of intensity, the metrics in PESTIMAT will make it possible to calculate exposure scores and to search for dose-effect relationships, an important criterion for causality judgment in epidemiology.

  18. Low-noise kinetic inductance traveling-wave amplifier using three-wave mixing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vissers, M. R.; Erickson, R. P.; Ku, H.-S.

    We have fabricated a wide-bandwidth, high dynamic range, low-noise cryogenic amplifier based on a superconducting kinetic inductance traveling-wave device. The device was made from NbTiN and consisted of a long, coplanar waveguide on a silicon chip. By adding a DC current and an RF pump tone, we are able to generate parametric amplification using three-wave mixing (3WM). The devices exhibit gain of more than 15 dB across an instantaneous bandwidth from 4 to 8 GHz. The total usable gain bandwidth, including both sides of the signal-idler gain region, is more than 6 GHz. The noise referred to the input of the devices approachesmore » the quantum limit, with less than 1 photon excess noise. We compare these results directly to the four-wave mixing amplification mode, i.e., without DC-biasing. We find that the 3WM mode allows operation with the pump at lower RF power and at frequencies far from the signal. We have used this knowledge to redesign the amplifiers to utilize primarily 3WM amplification, thereby allowing for direct integration into large scale qubit and detector applications.« less

  19. Dem Generation from Close-Range Photogrammetry Using Extended Python Photogrammetry Toolbox

    NASA Astrophysics Data System (ADS)

    Belmonte, A. A.; Biong, M. M. P.; Macatulad, E. G.

    2017-10-01

    Digital elevation models (DEMs) are widely used raster data for different applications concerning terrain, such as for flood modelling, viewshed analysis, mining, land development, engineering design projects, to name a few. DEMs can be obtained through various methods, including topographic survey, LiDAR or photogrammetry, and internet sources. Terrestrial close-range photogrammetry is one of the alternative methods to produce DEMs through the processing of images using photogrammetry software. There are already powerful photogrammetry software that are commercially-available and can produce high-accuracy DEMs. However, this entails corresponding cost. Although, some of these software have free or demo trials, these trials have limits in their usable features and usage time. One alternative is the use of free and open-source software (FOSS), such as the Python Photogrammetry Toolbox (PPT), which provides an interface for performing photogrammetric processes implemented through python script. For relatively small areas such as in mining or construction excavation, a relatively inexpensive, fast and accurate method would be advantageous. In this study, PPT was used to generate 3D point cloud data from images of an open pit excavation. The PPT was extended to add an algorithm converting the generated point cloud data into a usable DEM.

  20. Telecoil-mode hearing aid compatibility performance requirements for wireless and cordless handsets: magnetic signal-to-noise.

    PubMed

    Julstrom, Stephen; Kozma-Spytek, Linda; Isabelle, Scott

    2011-09-01

    During the revision of the American National Standards Institute (ANSI) C63.19 and the development of the ANSI/Telecommunications Industry Association-1083 hearing aid compatibility standards, it became evident that additional data concerning user acceptance of interfering magnetic noises generated by wireless and cordless telephones were needed in order to determine the requirements for telecoil-coupling compatibility. Further insight was needed into the magnetic signal-to-noise (S/N) ratios required to achieve specific levels of telephone usability by hearing aid wearers. (A companion article addresses magnetic signal level requirements.) Test subjects used their own hearing aids. The magnetic signals were applied through large magnetic head-worn coils, selected for the field orientation appropriate for each hearing aid. After adjusting their aid's volume control to an acoustic speech reference, the subjects adjusted the applied magnetic signal level to find their Most Comfortable Level (MCL). Each subject then adjusted the levels of six of eight different representative interfering noises to three levels of subjective telephone usability: "usable for a brief call," "acceptable for normal use," and "excellent performance." Each subject's objective noise audibility threshold in the presence of speech was also obtained for the various noise types. The 57 test subjects covered an age range of 22 to 79 yr, with a self-reported hearing loss duration of 12 to 72 yr. All had telecoils that they used for at least some telecommunications needs. The self-reported degree of hearing loss ranged from moderate to profound. A guided intake questionnaire yielded general background information for each subject. A test control box fed by prepared speech and noise recordings from computer files enabled the subject or the tester, depending on the portion of the test, to select A-weighting-normalized noise interference levels in 1.25 dB steps relative to the selected MCL. For each subject for each tested noise type, the values for the selected S/N ratios were recorded for the three categories of subjective usability and the objective noise threshold. About half of the test subjects needed a minimum 21 dB S/N ratio for them to consider their listening experience "acceptable for normal use" of a telephone. With a 30 dB S/N ratio, about 85% of the subjects reported normal use acceptability. Significant differences were apparent in the measured S/N user requirements among the noise types, though, indicating a deficiency in an A-weighted level measurement's ability to consistently predict the subjective acceptability of the various noises. An improved weighting function having both spectral and temporal components was developed to substantially eliminate these predictive inconsistencies. The interfering noise level that subjects chose for a telephone usability rating of "excellent performance" matched closely their objectively measured noise audibility threshold. A rating of "acceptable for normal use" was typically achieved at a 4 dB higher noise level, and a rating of "usable for a brief call," at a 10.4 dB higher noise level. These results did not relate significantly to noise type or to the subject's aided noise-in-speech hearing acuity. American Academy of Audiology.

  1. CUNY+ Web: Usability Study of the Web-Based GUI Version of the Bibliographic Database of the City University of New York (CUNY).

    ERIC Educational Resources Information Center

    Oulanov, Alexei; Pajarillo, Edmund J. Y.

    2002-01-01

    Describes the usability evaluation of the CUNY (City University of New York) information system in Web and Graphical User Interface (GUI) versions. Compares results to an earlier usability study of the basic information database available on CUNY's wide-area network and describes the applicability of the previous usability instrument to this…

  2. The Relationship between Personality Type and Software Usability Using the Myers-Briggs Type Indicator (MBTI) and the Software Usability Measurement Inventory (SUMI)

    ERIC Educational Resources Information Center

    Lindsey, William H.

    2011-01-01

    The study attempted to determine if there is a relationship between user's psychological personality types, measured by the Myers Briggs Type Indicator[R] (MBTI[R]) and distinct measures of usability measured by the Software Usability Measurement Inventory (SUMI). The study was expected to provide an answer to the following basic research…

  3. Mapping Usability: A Critical Research Analysis of Trends in Software Usability Research, Theory, and Practice

    ERIC Educational Resources Information Center

    Sousa, Morgan Margaret

    2009-01-01

    The impetus for this project stemmed from a curiosity about two particular areas in the history of usability research. For one, I began research for this project with a desire to learn about patterns in the theory, practice, attitude, and perception about usability work, both in academic contexts and in corporate contexts, with a focus on the…

  4. Effect of higher frequency on the classification of steady-state visual evoked potentials

    NASA Astrophysics Data System (ADS)

    Won, Dong-Ok; Hwang, Han-Jeong; Dähne, Sven; Müller, Klaus-Robert; Lee, Seong-Whan

    2016-02-01

    Objective. Most existing brain-computer interface (BCI) designs based on steady-state visual evoked potentials (SSVEPs) primarily use low frequency visual stimuli (e.g., <20 Hz) to elicit relatively high SSVEP amplitudes. While low frequency stimuli could evoke photosensitivity-based epileptic seizures, high frequency stimuli generally show less visual fatigue and no stimulus-related seizures. The fundamental objective of this study was to investigate the effect of stimulation frequency and duty-cycle on the usability of an SSVEP-based BCI system. Approach. We developed an SSVEP-based BCI speller using multiple LEDs flickering with low frequencies (6-14.9 Hz) with a duty-cycle of 50%, or higher frequencies (26-34.7 Hz) with duty-cycles of 50%, 60%, and 70%. The four different experimental conditions were tested with 26 subjects in order to investigate the impact of stimulation frequency and duty-cycle on performance and visual fatigue, and evaluated with a questionnaire survey. Resting state alpha powers were utilized to interpret our results from the neurophysiological point of view. Main results. The stimulation method employing higher frequencies not only showed less visual fatigue, but it also showed higher and more stable classification performance compared to that employing relatively lower frequencies. Different duty-cycles in the higher frequency stimulation conditions did not significantly affect visual fatigue, but a duty-cycle of 50% was a better choice with respect to performance. The performance of the higher frequency stimulation method was also less susceptible to resting state alpha powers, while that of the lower frequency stimulation method was negatively correlated with alpha powers. Significance. These results suggest that the use of higher frequency visual stimuli is more beneficial for performance improvement and stability as time passes when developing practical SSVEP-based BCI applications.

  5. Effect of higher frequency on the classification of steady-state visual evoked potentials.

    PubMed

    Won, Dong-Ok; Hwang, Han-Jeong; Dähne, Sven; Müller, Klaus-Robert; Lee, Seong-Whan

    2016-02-01

    Most existing brain-computer interface (BCI) designs based on steady-state visual evoked potentials (SSVEPs) primarily use low frequency visual stimuli (e.g., <20 Hz) to elicit relatively high SSVEP amplitudes. While low frequency stimuli could evoke photosensitivity-based epileptic seizures, high frequency stimuli generally show less visual fatigue and no stimulus-related seizures. The fundamental objective of this study was to investigate the effect of stimulation frequency and duty-cycle on the usability of an SSVEP-based BCI system. We developed an SSVEP-based BCI speller using multiple LEDs flickering with low frequencies (6-14.9 Hz) with a duty-cycle of 50%, or higher frequencies (26-34.7 Hz) with duty-cycles of 50%, 60%, and 70%. The four different experimental conditions were tested with 26 subjects in order to investigate the impact of stimulation frequency and duty-cycle on performance and visual fatigue, and evaluated with a questionnaire survey. Resting state alpha powers were utilized to interpret our results from the neurophysiological point of view. The stimulation method employing higher frequencies not only showed less visual fatigue, but it also showed higher and more stable classification performance compared to that employing relatively lower frequencies. Different duty-cycles in the higher frequency stimulation conditions did not significantly affect visual fatigue, but a duty-cycle of 50% was a better choice with respect to performance. The performance of the higher frequency stimulation method was also less susceptible to resting state alpha powers, while that of the lower frequency stimulation method was negatively correlated with alpha powers. These results suggest that the use of higher frequency visual stimuli is more beneficial for performance improvement and stability as time passes when developing practical SSVEP-based BCI applications.

  6. Usability study of the EduMod eLearning Program for contouring nodal stations of the head and neck.

    PubMed

    Deraniyagala, Rohan; Amdur, Robert J; Boyer, Arthur L; Kaylor, Scott

    2015-01-01

    A major strategy for improving radiation oncology education and competence evaluation is to develop eLearning programs that reproduce the real work environment. A valuable measure of the quality of an eLearning program is "usability," which is a multidimensional endpoint defined from the end user's perspective. The gold standard for measuring usability is the Software Usability Measurement Inventory (SUMI). The purpose of this study is to use the SUMI to measure usability of an eLearning course that uses innovative software to teach and test contouring of nodal stations of the head and neck. This is a prospective institutional review board-approved study in which all participants gave written informed consent. The study population was radiation oncology residents from 8 different programs across the United States. The subjects had to pass all sections of the same 2 eLearning modules and then complete the SUMI usability evaluation instrument. We reached the accrual goal of 25 participants. Usability results for the EduMod eLearning course, "Nodal Stations of the Head and Neck," were compared with a large database of scores of other major software programs. Results were evaluated in 5 domains: Affect, Helpfulness, Control, Learnability, and Global Usability. In all 5 domains, usability scores for the study modules were higher than the database mean and statistically superior in 4 domains. This is the first study to evaluate usability of an eLearning program related to radiation oncology. Usability of 2 representative modules related to contouring nodal stations of the head and neck was highly favorable, with scores that were superior to the industry standard in multiple domains. These results support the continued development of this type of eLearning program for teaching and testing radiation oncology technical skills. Copyright © 2015 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  7. Usability of clinical decision support system as a facilitator for learning the assistive technology adaptation process.

    PubMed

    Danial-Saad, Alexandra; Kuflik, Tsvi; Weiss, Patrice L Tamar; Schreuer, Naomi

    2016-01-01

    The aim of this study was to evaluate the usability of Ontology Supported Computerized Assistive Technology Recommender (OSCAR), a Clinical Decision Support System (CDSS) for the assistive technology adaptation process, its impact on learning the matching process, and to determine the relationship between its usability and learnability. Two groups of expert and novice clinicians (total, n = 26) took part in this study. Each group filled out system usability scale (SUS) to evaluate OSCAR's usability. The novice group completed a learning questionnaire to assess OSCAR's effect on their ability to learn the matching process. Both groups rated OSCAR's usability as "very good", (M [SUS] = 80.7, SD = 11.6, median = 83.7) by the novices, and (M [SUS] = 81.2, SD = 6.8, median = 81.2) by the experts. The Mann-Whitney results indicated that no significant differences were found between the expert and novice groups in terms of OSCAR's usability. A significant positive correlation existed between the usability of OSCAR and the ability to learn the adaptation process (rs = 0.46, p = 0.04). Usability is an important factor in the acceptance of a system. The successful application of user-centered design principles during the development of OSCAR may serve as a case study that models the significant elements to be considered, theoretically and practically in developing other systems. Implications for Rehabilitation Creating a CDSS with a focus on its usability is an important factor for its acceptance by its users. Successful usability outcomes can impact the learning process of the subject matter in general, and the AT prescription process in particular. The successful application of User-Centered Design principles during the development of OSCAR may serve as a case study that models the significant elements to be considered, theoretically and practically. The study emphasizes the importance of close collaboration between the developers and the end users.

  8. The Consumer Health Information System Adoption Model.

    PubMed

    Monkman, Helen; Kushniruk, Andre W

    2015-01-01

    Derived from overlapping concepts in consumer health, a consumer health information system refers to any of the broad range of applications, tools, and educational resources developed to empower consumers with knowledge, techniques, and strategies, to manage their own health. As consumer health information systems become increasingly popular, it is important to explore the factors that impact their adoption and success. Accumulating evidence indicates a relationship between usability and consumers' eHealth Literacy skills and the demands consumer HISs place on their skills. Here, we present a new model called the Consumer Health Information System Adoption Model, which depicts both consumer eHealth literacy skills and system demands on eHealth literacy as moderators with the potential to affect the strength of relationship between usefulness and usability (predictors of usage) and adoption, value, and successful use (actual usage outcomes). Strategies for aligning these two moderating factors are described.

  9. Health Information Technology Usability Evaluation Scale (Health-ITUES) for Usability Assessment of Mobile Health Technology: Validation Study.

    PubMed

    Schnall, Rebecca; Cho, Hwayoung; Liu, Jianfang

    2018-01-05

    Mobile technology has become a ubiquitous technology and can be particularly useful in the delivery of health interventions. This technology can allow us to deliver interventions to scale, cover broad geographic areas, and deliver technologies in highly tailored ways based on the preferences or characteristics of users. The broad use of mobile technologies supports the need for usability assessments of these tools. Although there have been a number of usability assessment instruments developed, none have been validated for use with mobile technologies. The goal of this work was to validate the Health Information Technology Usability Evaluation Scale (Health-ITUES), a customizable usability assessment instrument in a sample of community-dwelling adults who were testing the use of a new mobile health (mHealth) technology. A sample of 92 community-dwelling adults living with HIV used a new mobile app for symptom self-management and completed the Health-ITUES to assess the usability of the app. They also completed the Post-Study System Usability Questionnaire (PSSUQ), a widely used and well-validated usability assessment tool. Correlations between these scales and each of the subscales were assessed. The subscales of the Health-ITUES showed high internal consistency reliability (Cronbach alpha=.85-.92). Each of the Health-ITUES subscales and the overall scale was moderately to strongly correlated with the PSSUQ scales (r=.46-.70), demonstrating the criterion validity of the Health-ITUES. The Health-ITUES has demonstrated reliability and validity for use in assessing the usability of mHealth technologies in community-dwelling adults living with a chronic illness. ©Rebecca Schnall, Hwayoung Cho, Jianfang Liu. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 05.01.2018.

  10. Health Information Technology Usability Evaluation Scale (Health-ITUES) for Usability Assessment of Mobile Health Technology: Validation Study

    PubMed Central

    Cho, Hwayoung; Liu, Jianfang

    2018-01-01

    Background Mobile technology has become a ubiquitous technology and can be particularly useful in the delivery of health interventions. This technology can allow us to deliver interventions to scale, cover broad geographic areas, and deliver technologies in highly tailored ways based on the preferences or characteristics of users. The broad use of mobile technologies supports the need for usability assessments of these tools. Although there have been a number of usability assessment instruments developed, none have been validated for use with mobile technologies. Objective The goal of this work was to validate the Health Information Technology Usability Evaluation Scale (Health-ITUES), a customizable usability assessment instrument in a sample of community-dwelling adults who were testing the use of a new mobile health (mHealth) technology. Methods A sample of 92 community-dwelling adults living with HIV used a new mobile app for symptom self-management and completed the Health-ITUES to assess the usability of the app. They also completed the Post-Study System Usability Questionnaire (PSSUQ), a widely used and well-validated usability assessment tool. Correlations between these scales and each of the subscales were assessed. Results The subscales of the Health-ITUES showed high internal consistency reliability (Cronbach alpha=.85-.92). Each of the Health-ITUES subscales and the overall scale was moderately to strongly correlated with the PSSUQ scales (r=.46-.70), demonstrating the criterion validity of the Health-ITUES. Conclusions The Health-ITUES has demonstrated reliability and validity for use in assessing the usability of mHealth technologies in community-dwelling adults living with a chronic illness. PMID:29305343

  11. Inexpensive, easy-to-construct suction coring devices usable from small boats

    USGS Publications Warehouse

    Onuf, Christopher P.; Chapman, Duane C.; Rizzo, William M.

    1996-01-01

    Collection of sediment cores in depths of 1-5 m is difficult with traditional sampling gear. Here we describe three suction coring devices constructed with readily available plumbing supplies and parts easily made from acrylic plastic and silicone sealant. The samplers have been used successfully in sediments ranging from coarse sands and shell hash to muds, highly organic deposits, and dense clays. Successful applications have ranged from contaminants analysis, toxicity testing, seagrass mapping, and assessment of sediment-microfloral interactions to sampling the infauna of surf-swept beaches.

  12. 13 CFR 113.3-3 - Structural accommodations for handicapped clients.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... accessible to and usable by persons with handicaps. Alterations to existing facilities that affect usability... permitted where substantially equivalent or greater access to and usability of the building is provided. (2...

  13. You're a What? Usability Engineer.

    ERIC Educational Resources Information Center

    Crosby, Olivia

    2001-01-01

    Describes the work of usability engineers, who improve computer hardware, software, and websites by focusing on how users perceive and manipulate those tools. Discusses education, training, salaries, and talents needed by usability engineers. (Author/JOW)

  14. Development of the Telehealth Usability Questionnaire (TUQ).

    PubMed

    Parmanto, Bambang; Lewis, Allen Nelson; Graham, Kristin M; Bertolet, Marnie H

    2016-01-01

    Current telehealth usability questionnaires are designed primarily for older technologies, where telehealth interaction is conducted over dedicated videoconferencing applications. However, telehealth services are increasingly conducted over computer-based systems that rely on commercial software and a user supplied computer interface. Therefore, a usability questionnaire that addresses the changes in telehealth service delivery and technology is needed. The Telehealth Usability Questionnaire (TUQ) was developed to evaluate the usability of telehealth implementation and services. This paper addresses: (1) the need for a new measure of telehealth usability, (2) the development of the TUQ, (3) intended uses for the TUQ, and (4) the reliability of the TUQ. Analyses indicate that the TUQ is a solid, robust, and versatile measure that can be used to measure the quality of the computer-based user interface and the quality of the telehealth interaction and services.

  15. Effective Usability Engineering in Healthcare: A Vision of Usable and Safer Healthcare IT.

    PubMed

    Kushniruk, Andre; Senathirajah, Yalini; Borycki, Elizabeth

    2017-01-01

    Persistent problems with healthcare IT that is unusable and unsafe have been reported worldwide. In this paper we present our vision for deploying usability engineering in healthcare in a more substantive way in order to improve the current situation. The argument will be made that stronger and more substantial efforts need to be made to bring multiple usability engineering methods to bear on points in both system design and deployment (and not just as a one-time effort restricted to software product development). In addition, improved processes for ensuring the usability of commercial vendor-based systems being implemented in healthcare organizations need to be addressed. A discussion will also be provided on challenges and barriers that will need to be overcome to ensure that the heatlhcare IT that is released is both usable and safe.

  16. Comparison of two kinds of interface, based on guided navigation or usability principles, for improving the adoption of computerized decision support systems: application to the prescription of antibiotics.

    PubMed

    Tsopra, Rosy; Jais, Jean-Philippe; Venot, Alain; Duclos, Catherine

    2014-02-01

    It is important to consider the way in which information is presented by the interfaces of clinical decision support systems, to favor the adoption of these systems by physicians. Interface design can focus on decision processes (guided navigation) or usability principles. The aim of this study was to compare these two approaches in terms of perceived usability, accuracy rate, and confidence in the system. We displayed clinical practice guidelines for antibiotic treatment via two types of interface, which we compared in a crossover design. General practitioners were asked to provide responses for 10 clinical cases and the System Usability Scale (SUS) for each interface. We assessed SUS scores, the number of correct responses, and the confidence level for each interface. SUS score and percentage confidence were significantly higher for the interface designed according to usability principles (81 vs 51, p=0.00004, and 88.8% vs 80.7%, p=0.004). The percentage of correct responses was similar for the two interfaces. The interface designed according to usability principles was perceived to be more usable and inspired greater confidence among physicians than the guided navigation interface. Consideration of usability principles in the construction of an interface--in particular 'effective information presentation', 'consistency', 'efficient interactions', 'effective use of language', and 'minimizing cognitive load'--seemed to improve perceived usability and confidence in the system.

  17. Using a fuzzy comprehensive evaluation method to determine product usability: A proposed theoretical framework

    PubMed Central

    Zhou, Ronggang; Chan, Alan H. S.

    2016-01-01

    BACKGROUND: In order to compare existing usability data to ideal goals or to that for other products, usability practitioners have tried to develop a framework for deriving an integrated metric. However, most current usability methods with this aim rely heavily on human judgment about the various attributes of a product, but often fail to take into account of the inherent uncertainties in these judgments in the evaluation process. OBJECTIVE: This paper presents a universal method of usability evaluation by combining the analytic hierarchical process (AHP) and the fuzzy evaluation method. By integrating multiple sources of uncertain information during product usability evaluation, the method proposed here aims to derive an index that is structured hierarchically in terms of the three usability components of effectiveness, efficiency, and user satisfaction of a product. METHODS: With consideration of the theoretical basis of fuzzy evaluation, a two-layer comprehensive evaluation index was first constructed. After the membership functions were determined by an expert panel, the evaluation appraisals were computed by using the fuzzy comprehensive evaluation technique model to characterize fuzzy human judgments. Then with the use of AHP, the weights of usability components were elicited from these experts. RESULTS AND CONCLUSIONS: Compared to traditional usability evaluation methods, the major strength of the fuzzy method is that it captures the fuzziness and uncertainties in human judgments and provides an integrated framework that combines the vague judgments from multiple stages of a product evaluation process. PMID:28035943

  18. Relationship Between Evidence Requirements, User Expectations, and Actual Experiences: Usability Evaluation of the Twazon Arabic Weight Loss App

    PubMed Central

    Kyle, Janet; Alkhalifah, Abdulrahman; Marais, Debbi

    2018-01-01

    Background Saudi Arabia has faced a steady growth in the prevalence of obesity. The concurrent and ubiquitous use of mobile technology, such as smartphones and apps, provides an opportunity for the implementation of mHealth technology, a method for delivering behavioral interventions. Despite their effectiveness in promoting lifestyle and diet modification, culturally adapted weight loss apps and related interventions are lacking in Gulf Cooperation Council countries. Objective The objective of our study was to identify the relationship between adherence to evidence-informed practices, potential user expectations, and actual user experiences in order to enhance the understanding of the overall usability of the Twazon Arabic weight loss app. Methods In 2 previous studies, 39 Saudi women were recruited for focus group discussions and 240 Saudi women were recruited for an app-based weight loss intervention. Usability of the Twazon Arabic weight loss app was evaluated by analyzing the opinions and experiences of 26 participants who engaged with the Twazon app for 4 months; the System Usability Scale (SUS) and word clouds were used. The results were triangulated with potential user expectations obtained in the focus group discussion and with the findings from an Arabic app screening for evidence-informed practices. Results The average reported SUS score was 69.3. The most favored features were the calorie counter, step counter, and physical activity calorie counter. The features in need of improvement were the social network, notifications, and the Twazon Saudi Food Database. Twazon users preferred and found useful 7 of the 13 evidence-informed weight loss practices that were integrated into the features of the app. Conclusions Triangulation identified the most notable relationship to be the disparity between user experience and 2 of the evidence-informed practices, namely a minimum weight loss goal of 0.5 to 1 kg/week and social support; no relationship was found between user expectations and evidence-informed weight loss practices. The overall usability of the Twazon Arabic weight loss app ranged between high marginal and acceptable, indicating that some improvements to the app should be considered for implementation in future app-based weight loss interventions of this kind. PMID:29666042

  19. Doubling the Spectrum of Time-Domain Induced Polarization: Removal of Harmonic Noise and Self-Potential Drift

    NASA Astrophysics Data System (ADS)

    Fiandaca, G.; Olsson, P. I.; Auken, E.; Larsen, J. J.; Maurya, P. K.; Dahlin, T.

    2015-12-01

    The extraction of spectral information in the inversion process of time-domain (TD) induced polarization (IP) data is changing the use of the IP method. Data interpretation is evolving from a qualitative description of the soil, able only to discriminate the presence of contrasts in chargeability parameters, towards a quantitative analysis of the investigated media, which allows soil-type characterization. Two major limitations restrict the extraction of the spectral information of TDIP data in the field: i) the difficulty of acquiring reliable early-time measurements, in the millisecond range and ii) the self-potential drift in the measured potentials distorting the shape of the late time IP decays, in the second range. For measuring at early-times, we developed a new method for removing the powerline noise contained in the data through a model-based approach, localizing the fundamental frequency of the powerline signal in the full-waveform IP recordings. By this, we cancel both the fundamental signal and its harmonics. This noise cancellation allows the use of earlier and narrower gates, down to a few milliseconds after the current turn-off. Even earlier gates can be measured but they will be inductively "contaminated" which we at present want to avoid. A proper removal of the self-potential drift present between the potential electrodes is essential for preserving the shape of the TD decays, especially for late times. Usually constant or linear drift-removal algorithms are used, but these algorithms fail in removing the background potentials due to the polarization of the electrodes previously used for current injection. We developed a drift-removal scheme that model the polarization effect and efficiently allows for preserving the shape of the IP decays. The removal of both the harmonic noise and self-potential drift allows for doubling the usable range of TDIP data to more than three decades in time (corresponding to three decays in frequency), and will significantly advance the science and the applicability of the IP method in exploration and environmental geophysics.

  20. Web usability evaluation on BloobIS website by using hallway usability testing method and ISO 9241:11

    NASA Astrophysics Data System (ADS)

    Dwi Susanto, Tony; Ingesti Prasetyo, Anisa; Astuti, Hanim Maria

    2018-03-01

    At this moment, the need for web as an information media is highly important. Not only confined in the infotainment area, government, and education, but health as well uses the web media as a medium for providing information effectively. BloobIS is a web based application which integrates blood supply and distribution information at the Blood Transfusion Unit. Knowing how easy information is on BloobIS is marked by how convenient the website is used. Up until now, the BloobIS website is nearing completion but testing has not yet been performed to users and is on the testing and development phase in the Development Life Cycle software. Thus, an evaluation namely the quality control software which focuses on the perspective of BloobIs web usability is required. Hallway Usability Testing and ISO 9241:11 are the methods chosen to measure the BloobIS application usability. The expected outputs of the quality control software focusing on the usability evaluation are being able to rectify the usability deficiencies on the BloobIs web and provide recommendations to develop the web as a basic BloobIS web quality upgraed which sets a goal to amplify the satisfaction of web users based on usability factors in ISO 9241:11.

  1. Optimal use of electrophysiological indicators of muscular effort and fatigue

    NASA Technical Reports Server (NTRS)

    Updike, O. L.

    1981-01-01

    Electromyograms (EMG) from working muscles convey information on effort and fatigue. Their application, e.g., to assess the demands of vehicle control tasks, is complicated by the cooperative action of sets of muscles, by both intrinsic and imposed filtering, and by numerous other sources of variation. Fourier analyses of these noise like signals offer one approach to interpretation; downward spectral shifts accompany fatigue. Techniques are being sought (in both time and frequency domains) for further condensing the wideband EMG signals, while retaining essential information, into a concise 'state vector' usable in comparing control system designs.

  2. Monolithic carrier-envelope phase-stabilization scheme.

    PubMed

    Fuji, Takao; Rauschenberger, Jens; Apolonski, Alexander; Yakovlev, Vladislav S; Tempea, Gabriel; Udem, Thomas; Gohle, Christoph; Hänsch, Theodor W; Lehnert, Walter; Scherer, Michael; Krausz, Ferenc

    2005-02-01

    A new scheme for stabilizing the carrier-envelope (CE) phase of a few-cycle laser pulse train is demonstrated. Self-phase modulation and difference-frequency generation in a single periodically poled lithium niobate crystal that transmits the main laser beam allows CE phase locking directly in the usable output. The monolithic scheme obviates the need for splitting off a fraction of the laser output for CE phase control, coupling into microstructured fiber, and separation and recombination of spectral components. As a consequence, the output yields 6-fs, 800-nm pulses with an unprecedented degree of short- and long-term reproducibility of the electric field waveform.

  3. Interface Usability Across and Within EHR Vendors and Medical Settings: The Often Unexamined Need for Interface Similarities.

    PubMed

    Koppel, Ross; Kuziemsky, Craig

    2017-01-01

    Usability of health information technology (HIT), if considered at all, is usually focused on individual providers, settings and vendors. However, in light of transformative models of healthcare delivery such as collaborative care delivery that crosses providers and settings, we need to think of usability as a collective and constantly emerging process. To address this new reality we develop a matrix of usability that spans several dimensions and contexts, incorporating differing vendors, user, settings, disciplines, and display configurations. The matrix, while conceptual, extends existing work by providing the means for discussion of usability issues and needs beyond one setting and one user type.

  4. LATCH usability in vehicles.

    DOT National Transportation Integrated Search

    2012-04-01

    This project investigated the usability of Lower Anchors and Tethers for CHildren (LATCH) hardware by measuring LATCH implementations in 98 2011 or 2010 model-year vehicles. ISO and SAE LATCH usability rating systems were used to assess all vehicles ...

  5. Applying usability testing techniques to improve a health promotion website.

    PubMed

    Hinchliffe, Anetta; Mummery, W Kerry

    2008-04-01

    Use of the Internet for health promotion is increasing; however, the lack of published research regarding website usability suggests that health promotion websites are being developed without consultation with their users or formal evaluation. This study conducted usability testing of an existing health promotion website to inform modifications and to identify common usability themes that should be addressed by organisations developing or maintaining a health promotion website. A combination of qualitative and quantitative techniques were implemented during the usability testing sessions to gather data from users while completing tasks on the website. Techniques included performance measures (time taken), direct observation (participant observation) and subjective user preferences (questionnaire and interview). Improvements to the website were measured in terms of reduced problems reported, reduced time taken to complete tasks and increased subjective reports. Seven usability themes emerged from the data: design, feedback, format, instructions, navigation, terminology and learnability. This study demonstrates the application of usability testing to the design and modification of a health promotion website and illustrates the areas or themes that can be used as a framework for testing and modification.

  6. National questionnaire study on clinical ICT systems proofs: physicians suffer from poor usability.

    PubMed

    Viitanen, Johanna; Hyppönen, Hannele; Lääveri, Tinja; Vänskä, Jukka; Reponen, Jarmo; Winblad, Ilkka

    2011-10-01

    In the health informatics field, usability studies typically focus on evaluating a single information system and involve a rather small group of end-users. However, little is known about the usability of clinical information and communication technology (ICT) environment in which healthcare professionals work daily. This paper aims at contributing to usability research and user-oriented development of healthcare technologies with three objectives: inform researchers and practitioners about the current state of usability of clinical ICT systems, increase the understanding of usability aspects specific for clinical context, and encourage a more holistic approach on studying usability issues in health informatics field. A national web questionnaire study was conducted in Finland in spring 2010 with 3929 physicians actively working in patient care. For the purposes of the study, we described three dimensions of clinical ICT system usability that reflect the physicians' viewpoint on system usage: (1) compatibility between clinical ICT systems and physicians' tasks, (2) ICT support for information exchange, communication and collaboration in clinical work, and (3) interoperability and reliability. The dimensions derive from the definitions of usability and clinical context of use analysis, and reflect the ability of ICT systems to have a positive impact on patient care by supporting physicians in achieving their goals with a pleasant user experience. The research data incorporated 32 statements with a five-point Likert-scale on physicians' experiences on usability of their currently used ICT systems and a summative question about school grade given to electronic health record (EHR) systems. Physicians' estimates of their EHR systems were very critical. With the rating scale from 4 or fail to 10 or excellent, the average of the grades varied from 6.1 to 8.4 dependent on the kind of facility the physician is working. Questionnaire results indicated several usability problems and deficiencies which considerably hindered the efficiency of clinical ICT use and physician's routine work. Systems lacked the appropriate features to support typical clinical tasks, such as decision making, prevention of medical errors, and review of a patient's treatment chart. The systems also required physicians to perform fixed sequences of steps and tasks, and poorly supported the documentation and retrieval of patient data. The findings on ICT support for collaboration showed mainly negative results, aside from collaboration between co-located physicians. In addition, the study results pointed out physicians suffering from system failures and a lack of integration between the systems. The described study and related results are unique in several ways. A national usability study with nearly 4000 respondents had not been conducted in other countries in which healthcare technologies are widely adopted. The questionnaire study provided a generalized picture about the usability problems, however, it should be noted that there were significant differences between legacy systems in use. Previously, researchers had not approached contextual aspects of usability the context of clinical work, where numerous systems are in use. The described usability dimensions and the presented study results can be considered as the first step towards conceptualizing ICT usability in the unique setting of clinical work. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  7. Radio Frequency Interference: Radio Astronomy's Biggest Enemy

    NASA Astrophysics Data System (ADS)

    Acevedo, F.; Ghosh, Tapasi

    1997-12-01

    As technology progresses, the demand for the usage of the electromagnetic spectrum increases with it. The development is so fast and prolific that clean band space for passive users such as Radio Astronomy is becoming ever so scarce. Even though, several spectral bands have been protected for Radio Astronomy by Federal Communication Commission (in the USA) under the recommendations of the International Telecommunication Union (ITU), pressure for making more spectral space commercially usable is extreme. Although these commercial usages make our modern living at all possible, often the extreme vulnerability of passive users are are not fully appreciated, resulting in unwanted emissions (RFI) in the Radio Astronomy Bands. Another source of RFI is the fact that many of the electronic devices used in the observatories themselves generate radio waves. If proper precautions are not taken, these can be received back through the Radio Telescope itself. This problem is referred to as internal RFI. The focus of this paper is the search and diminution of internal RFI in the Arecibo Observatory in Arecibo, Puerto Rico. Using a simple setup of a log-periodic antenna and a Spectrum Analyzer, spectra spanning a frequency range of 100 - 1800 MHZ were recorded in some areas of the Observatory and the new Visitor Center (AOVEF). The measurements disclosed sources of radio emission among some of the digital electronic equipment in the Equipment room and a few displays in the AOVEF. Most prominent of these was a 2.5 MHz comb spanning the entire range of the measurements emitted from the SRENDIP and AOFTM machines. The respective groups were informed and corrective shielding & isolations were implemented immediately. In AOVEF, three displays, some audio-visual equipment, and video/digital cameras used by the visitors were found to be "leaky". In future, the use of such cameras will be prohibited and the exhibits will be screened appropriately.

  8. Assessment of diet and physical activity of brazilian schoolchildren: usability testing of a web-based questionnaire.

    PubMed

    da Costa, Filipe Ferreira; Schmoelz, Camilie Pacheco; Davies, Vanessa Fernandes; Di Pietro, Patrícia Faria; Kupek, Emil; de Assis, Maria Alice Altenburg

    2013-08-19

    Information and communication technology (ICT) has been used with increasing frequency for the assessment of diet and physical activity in health surveys. A number of Web-based questionnaires have been developed for children and adolescents. However, their usability characteristics have scarcely been reported, despite their potential importance for improving the feasibility and validity of ICT-based methods. The objective of this study was to describe the usability evaluation of the Consumo Alimentar e Atividade Física de Escolares (CAAFE) questionnaire (Food Consumption and Physical Activity Questionnaire for schoolchildren), a new Web-based survey tool for the self-assessment of diet and physical activity by schoolchildren. A total of 114 schoolchildren aged 6 to 12 years took part in questionnaire usability testing carried out in computer classrooms at five elementary schools in the city of Florianopolis, Brazil. Schoolchildren used a personal computer (PC) equipped with software for recording what is on the computer screen and the children's speech during usability testing. Quantitative and qualitative analyses took into account objective usability metrics such as error counts and time to complete a task. Data on the main difficulties in accomplishing the task and the level of satisfaction expressed by the children were assessed by the observers using a standardized form and interviews with the children. Descriptive statistics and content analysis were used to summarize both the quantitative and the qualitative aspects of the data obtained. The mean time for completing the questionnaire was 13.7 minutes (SD 3.68). Compared to the children in 2nd or 3rd grades, those in 4th or 5th grades spent less time completing the questionnaire (median 12.4 vs 13.3 minutes, P=.022), asked for help less frequently (median 0 vs 1.0 count, P=.005), had a lower error count (median 2.0 vs 8.0 count, P<.001), and obtained a higher overall performance score (median 73.0 vs 68.0, P=.005). Children with a PC at home spent less time completing the questionnaire (median 12.3 vs 14.9 minutes, P<.001), had a lower overall error count (median 2.0 vs 9.0 count, P=.03), and had a higher performance score (median 72.0 vs 64.0, P=.005) compared to the children without a PC at home. The most common difficulty in completing the questionnaire was in using the scroll bar. The majority of children reported a positive evaluation (liked a lot or liked) for the four design elements, which were evaluated. The results of the present study provided feedback to improve the final version of the CAAFE questionnaire. Quantitative data showed minor errors and system failures, while qualitative data indicated that, overall, the children enjoyed the CAAFE questionnaire. Grade levels and PC use must be taken into account in Web-based tools designed for children.

  9. A knitted garment using intarsia technique for Heart Rate Variability biofeedback: Evaluation of initial prototype.

    PubMed

    Abtahi, F; Ji, G; Lu, K; Rödby, K; Seoane, F

    2015-01-01

    Heart rate variability (HRV) biofeedback is a method based on paced breathing at specific rate called resonance frequency by giving online feedbacks from user respiration and its effect on HRV. Since the HRV is also influence by different factors like stress and emotions, stress related to an unfamiliar measurement device, cables and skin electrodes may cover the underling effect of such kind of intervention. Wearable systems are usually considered as intuitive solutions which are more familiar to the end-user and can help to improve usability and hence reducing the stress. In this work, a prototype of a knitted garment using intarsia technique is developed and evaluated. Results show the satisfactory level of quality for Electrocardiogram and thoracic electrical bioimpedance i.e. for respiration monitoring as a part of HRV biofeedback system. Using intarsia technique and conductive yarn for making the connection instead of cables will reduce the complexity of fabrication in textile production and hence reduce the final costs in a final commercial product. Further development of garment and Android application is ongoing and usability and efficiency of final prototype will be evaluated in detail.

  10. Graphical content of medicinal package inserts: an exploratory study to evaluate potential legibility issues.

    PubMed

    Pires, Carla; Vigário, Marina; Cavaco, Afonso

    2016-06-01

    The graphical content of the Medicines Package Inserts (MPIs), such as illustrations and typographic features should be legible and appropriate, as required by international pharmaceutical regulations. To study: (1) the frequency and type of MPIs' key graphic elements, (2) their compliance with regulations and (3) how educated people understand them. Descriptive study: characterisation of the graphical content of 651 MPIs. Usability study: illustrations and tables (purposively selected) were evaluated with questionnaires in three groups of humanities undergraduates (illustrations only, illustrations plus text and text only). Descriptive study: illustrations and tables were respectively identified in 6.3% and 11.8% of the MPIs. The illustrations were mainly related to how to take/use the medicine. Non-recommended graphical representations were found (e.g. italic or underline). Usability test: legibility issues were identified, especially for the group of isolated illustrations. The scarce use of illustrations and tables possibly affected the legibility of the MPIs. Compulsory legibility tests are needed to guarantee the MPIs' proper use, thus contributing to a safe use of medicines. Overall, this study highlighted the need to carefully revise/assess the MPIs' design and probably increase health information experts' awareness on this issue. © 2015 Health Libraries Group.

  11. Wide bandwidth phase-locked loop circuit

    NASA Technical Reports Server (NTRS)

    Koudelka, Robert David (Inventor)

    2005-01-01

    A PLL circuit uses a multiple frequency range PLL in order to phase lock input signals having a wide range of frequencies. The PLL includes a VCO capable of operating in multiple different frequency ranges and a divider bank independently configurable to divide the output of the VCO. A frequency detector detects a frequency of the input signal and a frequency selector selects an appropriate frequency range for the PLL. The frequency selector automatically switches the PLL to a different frequency range as needed in response to a change in the input signal frequency. Frequency range hysteresis is implemented to avoid operating the PLL near a frequency range boundary.

  12. Disruptive Innovation: Implementation of Electronic Consultations in a Veterans Affairs Health Care System

    PubMed Central

    Clark, Justice

    2016-01-01

    Background Electronic consultations (e-consults) offer rapid access to specialist input without the need for a patient visit. E-consult implementation began in 2011 at VA Boston Healthcare System (VABHS). By early 2013, e-consults were available for all clinical services. In this implementation, the requesting clinician selects the desired consultation within the electronic health record (EHR) ordering menu, which creates an electronic form that is pre-populated with patient demographic information and allows free-text entry of the reason for consult. This triggers a message to the requesting clinician and requested specialty, thereby enabling bidirectional clinician-clinician communication. Objective The aim of this study is to examine the utilization of e-consults in a large Veterans Affairs (VA) health care system. Methods Data from the electronic health record was used to measure frequency of e-consult use by provider type (physician or nurse practitioner (NP) and/or physician assistant), and by the requesting and responding specialty from January 2012 to December 2013. We conducted chart reviews for a purposive sample of e-consults and semi-structured interviews with a purposive sample of clinicians and hospital leaders to better characterize the process, challenges, and usability of e-consults. Results A total of 7097 e-consults were identified, 1998 from 2012 and 5099 from 2013. More than one quarter (27.56%, 1956/7097) of the e-consult requests originated from VA facilities in New England other than VABHS and were excluded from subsequent analysis. Within the VABHS e-consults (72.44%, 5141/7097), variability in frequency and use of e-consults across provider types and specialties was found. A total of 64 NPs requested 2407 e-consults (median 12.5, range 1-415). In contrast, 448 physicians (including residents and fellows) requested 2349 e-consults (median 2, range 1-116). More than one third (37.35%, 1920/5141) of e-consults were sent from primary care to specialists. While most e-consults reflected a request for specialist input to a generalist’s question in diagnosis or management in the ambulatory setting, we identified creative uses of e-consults, including requests for face-to-face appointments and documentation of pre-operative chart reviews; moreover, 7.00% (360/5141) of the e-consults originated from our sub-acute and chronic care inpatient units. In interviews, requesting providers reported high utility and usability. Specialists recognized the value of e-consults but expressed concerns about additional workload. Conclusions The e-consult mechanism is frequently utilized for its initial intended purpose. It has also been adopted for unexpected clinical and administrative uses, developing into a “disruptive innovation” and highlighting existing gaps in mechanisms for provider communication. Further investigation is needed to characterize optimal utilization of e-consults within specialty and the medical center, and what features of the e-consult program, other than volume, represent valid measures of access and quality care. PMID:26872820

  13. Disruptive Innovation: Implementation of Electronic Consultations in a Veterans Affairs Health Care System.

    PubMed

    Gupte, Gouri; Vimalananda, Varsha; Simon, Steven R; DeVito, Katerina; Clark, Justice; Orlander, Jay D

    2016-02-12

    Electronic consultations (e-consults) offer rapid access to specialist input without the need for a patient visit. E-consult implementation began in 2011 at VA Boston Healthcare System (VABHS). By early 2013, e-consults were available for all clinical services. In this implementation, the requesting clinician selects the desired consultation within the electronic health record (EHR) ordering menu, which creates an electronic form that is pre-populated with patient demographic information and allows free-text entry of the reason for consult. This triggers a message to the requesting clinician and requested specialty, thereby enabling bidirectional clinician-clinician communication. The aim of this study is to examine the utilization of e-consults in a large Veterans Affairs (VA) health care system. Data from the electronic health record was used to measure frequency of e-consult use by provider type (physician or nurse practitioner (NP) and/or physician assistant), and by the requesting and responding specialty from January 2012 to December 2013. We conducted chart reviews for a purposive sample of e-consults and semi-structured interviews with a purposive sample of clinicians and hospital leaders to better characterize the process, challenges, and usability of e-consults. A total of 7097 e-consults were identified, 1998 from 2012 and 5099 from 2013. More than one quarter (27.56%, 1956/7097) of the e-consult requests originated from VA facilities in New England other than VABHS and were excluded from subsequent analysis. Within the VABHS e-consults (72.44%, 5141/7097), variability in frequency and use of e-consults across provider types and specialties was found. A total of 64 NPs requested 2407 e-consults (median 12.5, range 1-415). In contrast, 448 physicians (including residents and fellows) requested 2349 e-consults (median 2, range 1-116). More than one third (37.35%, 1920/5141) of e-consults were sent from primary care to specialists. While most e-consults reflected a request for specialist input to a generalist's question in diagnosis or management in the ambulatory setting, we identified creative uses of e-consults, including requests for face-to-face appointments and documentation of pre-operative chart reviews; moreover, 7.00% (360/5141) of the e-consults originated from our sub-acute and chronic care inpatient units. In interviews, requesting providers reported high utility and usability. Specialists recognized the value of e-consults but expressed concerns about additional workload. The e-consult mechanism is frequently utilized for its initial intended purpose. It has also been adopted for unexpected clinical and administrative uses, developing into a "disruptive innovation" and highlighting existing gaps in mechanisms for provider communication. Further investigation is needed to characterize optimal utilization of e-consults within specialty and the medical center, and what features of the e-consult program, other than volume, represent valid measures of access and quality care.

  14. Investigating the effect of m-commerce design usability on customers' trust

    NASA Astrophysics Data System (ADS)

    Hussain, Azham Bin; Mahmood, Alaa Thamer; Naser, Raed Kamil

    2017-10-01

    User experience may vary from one user to another based on the design characteristics for processing a certain task. Our review of the literature revealed that there is a noticeable lack of studies on the effect of mobile or m-commerce design usability on customers' trust to perform certain activities. We investigated the effect of m-commerce design usability in terms of navigability, supportability, readability, creditability, and content relevant. A close-ended questionnaire was distributed to 20 customers who were asked to perform some tasks. The result showed that majority of the participants found m-commerce design usability to influence their trust of the app. The mentioned usability elements were found to positively influence customers' trust except for supportability. Our findings provide some insights to the m-commerce designers and developers and extend the current understanding about the potential of design usability in explaining users' usage behavior.

  15. Usability engineering: domain analysis activities for augmented-reality systems

    NASA Astrophysics Data System (ADS)

    Gabbard, Joseph; Swan, J. E., II; Hix, Deborah; Lanzagorta, Marco O.; Livingston, Mark; Brown, Dennis B.; Julier, Simon J.

    2002-05-01

    This paper discusses our usability engineering process for the Battlefield Augmented Reality System (BARS). Usability engineering is a structured, iterative, stepwise development process. Like the related disciplines of software and systems engineering, usability engineering is a combination of management principals and techniques, formal and semi- formal evaluation techniques, and computerized tools. BARS is an outdoor augmented reality system that displays heads- up battlefield intelligence information to a dismounted warrior. The paper discusses our general usability engineering process. We originally developed the process in the context of virtual reality applications, but in this work we are adapting the procedures to an augmented reality system. The focus of this paper is our work on domain analysis, the first activity of the usability engineering process. We describe our plans for and our progress to date on our domain analysis for BARS. We give results in terms of a specific urban battlefield use case we have designed.

  16. A Persuasive and Social mHealth Application for Physical Activity: A Usability and Feasibility Study

    PubMed Central

    Al Ayubi, Soleh U; Branch, Robert; Ding, Dan

    2014-01-01

    Background Advances in smartphones and the wide usage of social networking systems offer opportunities for the development of innovative interventions to promote physical activity. To that end, we developed a persuasive and social mHealth application designed to monitor and motivate users to walk more every day. Objective The objectives of this project were to conduct a focused review on the fundamental characteristics of mHealth for physical activity promotion, to develop an mHealth application that meets such characteristics, and to conduct a feasibility study to deploy the application in everyday life. Methods This project started as an analytical study to review the fundamental characteristics of the technologies used in physical activity monitoring and promotion. Then, it was followed by a technical development of the application. Next, a 4 week deployment was conducted where participants used the application as part of their daily life. A think-aloud method and in-depth semistructured interviews were conducted following the deployment. A qualitative description method was used to thematically analyze the interviews. Feasibility measures included, adherence to the program, user-system interactions, motivation to use, and experience with physical activity and online social interactions. Results There were seven fundamental characteristics of physical activity monitoring and promotion that were identified, which were then used as a foundation to develop the application. There were fourteen participants that enrolled in the application evaluation. The age range was from 24 to 45; body mass index ranged from 18.5 to 42.98, with 4 of the subjects falling into the category “obese”. Half of them were experienced with smartphones, and all were familiar with a social network system. There were thirteen participants that completed the study; one was excluded. Overall, participants gave high scores to almost all of the usability factors examined, with averages of 4.52 out of a 5.00 maximum. Over 29 days, participants used the application for a total of 119,380 minutes (average=7.57 hours/day/participant; SD 1.56). Conclusions Based on the fundamental characteristics, the application was successfully developed. The usability results suggest that the system is usable and user satisfaction was high. Deploying the application was shown to be feasible for the promotion of daily physical activity. PMID:25099928

  17. A Persuasive and Social mHealth Application for Physical Activity: A Usability and Feasibility Study.

    PubMed

    Al Ayubi, Soleh U; Parmanto, Bambang; Branch, Robert; Ding, Dan

    2014-05-22

    Advances in smartphones and the wide usage of social networking systems offer opportunities for the development of innovative interventions to promote physical activity. To that end, we developed a persuasive and social mHealth application designed to monitor and motivate users to walk more every day. The objectives of this project were to conduct a focused review on the fundamental characteristics of mHealth for physical activity promotion, to develop an mHealth application that meets such characteristics, and to conduct a feasibility study to deploy the application in everyday life. This project started as an analytical study to review the fundamental characteristics of the technologies used in physical activity monitoring and promotion. Then, it was followed by a technical development of the application. Next, a 4 week deployment was conducted where participants used the application as part of their daily life. A think-aloud method and in-depth semistructured interviews were conducted following the deployment. A qualitative description method was used to thematically analyze the interviews. Feasibility measures included, adherence to the program, user-system interactions, motivation to use, and experience with physical activity and online social interactions. There were seven fundamental characteristics of physical activity monitoring and promotion that were identified, which were then used as a foundation to develop the application. There were fourteen participants that enrolled in the application evaluation. The age range was from 24 to 45; body mass index ranged from 18.5 to 42.98, with 4 of the subjects falling into the category "obese". Half of them were experienced with smartphones, and all were familiar with a social network system. There were thirteen participants that completed the study; one was excluded. Overall, participants gave high scores to almost all of the usability factors examined, with averages of 4.52 out of a 5.00 maximum. Over 29 days, participants used the application for a total of 119,380 minutes (average=7.57 hours/day/participant; SD 1.56). Based on the fundamental characteristics, the application was successfully developed. The usability results suggest that the system is usable and user satisfaction was high. Deploying the application was shown to be feasible for the promotion of daily physical activity.

  18. Frequency Domain Beamforming for a Deep Space Network Downlink Array

    NASA Technical Reports Server (NTRS)

    Navarro, Robert

    2012-01-01

    This paper describes a frequency domain beamformer to array up to 8 antennas of NASA's Deep Space Network currently in development. The objective of this array is to replace and enhance the capability of the DSN 70m antennas with multiple 34m antennas for telemetry, navigation and radio science use. The array will coherently combine the entire 500 MHz of usable bandwidth available to DSN receivers. A frequency domain beamforming architecture was chosen over a time domain based architecture to handle the large signal bandwidth and efficiently perform delay and phase calibration. The antennas of the DSN are spaced far enough apart that random atmospheric and phase variations between antennas need to be calibrated out on an ongoing basis in real-time. The calibration is done using measurements obtained from a correlator. This DSN Downlink Array expands upon a proof of concept breadboard array built previously to develop the technology and will become an operational asset of the Deep Space Network. Design parameters for frequency channelization, array calibration and delay corrections will be presented as well a method to efficiently calibrate the array for both wide and narrow bandwidth telemetry.

  19. Automatic analysis of ciliary beat frequency using optical flow

    NASA Astrophysics Data System (ADS)

    Figl, Michael; Lechner, Manuel; Werther, Tobias; Horak, Fritz; Hummel, Johann; Birkfellner, Wolfgang

    2012-02-01

    Ciliary beat frequency (CBF) can be a useful parameter for diagnosis of several diseases, as e.g. primary ciliary dyskinesia. (PCD). CBF computation is usually done using manual evaluation of high speed video sequences, a tedious, observer dependent, and not very accurate procedure. We used the OpenCV's pyramidal implementation of the Lukas-Kanade algorithm for optical flow computation and applied this to certain objects to follow the movements. The objects were chosen by their contrast applying the corner detection by Shi and Tomasi. Discrimination between background/noise and cilia by a frequency histogram allowed to compute the CBF. Frequency analysis was done using the Fourier transform in matlab. The correct number of Fourier summands was found by the slope in an approximation curve. The method showed to be usable to distinguish between healthy and diseased samples. However there remain difficulties in automatically identifying the cilia, and also in finding enough high contrast cilia in the image. Furthermore the some of the higher contrast cilia are lost (and sometimes found) by the method, an easy way to distinguish the correct sub-path of a point's path have yet to be found in the case where the slope methods doesn't work.

  20. User perspectives on the usability of a regional health information exchange

    PubMed Central

    Ho, Yun-Xian; Cala, Cather Marie; Blakemore, Dana; Chen, Qingxia; Frisse, Mark E; Johnson, Kevin B

    2011-01-01

    Objective We assessed the usability of a health information exchange (HIE) in a densely populated metropolitan region. This grant-funded HIE had been deployed rapidly to address the imminent needs of the patient population and the need to draw wider participation from regional entities. Design We conducted a cross-sectional survey of individuals given access to the HIE at participating organizations and examined some of the usability and usage factors related to the technology acceptance model. Measurements We probed user perceptions using the Questionnaire for User Interaction Satisfaction, an author-generated Trust scale, and user characteristic questions (eg, age, weekly system usage time). Results Overall, users viewed the system favorably (ratings for all usability items were greater than neutral (one-sample Wilcoxon test, p<0.0014, Bonferroni-corrected for 35 tests). System usage was regressed on usability, trust, and demographic and user characteristic factors. Three usability factors were positively predictive of system usage: overall reactions (p<0 0.01), learning (p<0.05), and system functionality (p<0.01). Although trust is an important component in collaborative relationships, we did not find that user trust of other participating healthcare entities was significantly predictive of usage. An analysis of respondents' comments revealed ways to improve the HIE. Conclusion We used a rapid deployment model to develop an HIE and found that perceptions of system usability were positive. We also found that system usage was predicted well by some aspects of usability. Results from this study suggest that a rapid development approach may serve as a viable model for developing usable HIEs serving communities with limited resources. PMID:21622933

  1. Why Citizen Science Without Usability Testing Will Underperform

    NASA Astrophysics Data System (ADS)

    Romano, C.; Gay, P.; Owens, R.; Burlea, G.

    2017-12-01

    Citizen science projects must undergo usability testing and optimization if they are to meet their stated goals. This presentation will include video of usability tests conducted upon citizen science websites. Usability testing is essential to the success of online interaction, however, citizen science projects have just begun to include this critical activity. Interaction standards in citizen science lag behind those of commercial interests, and published research on this topic is limited. Since online citizen science is by definition, an exchange of information, a clear understanding of how users experience an online project is essential to informed decision-making. Usability testing provides that insight. Usability testing collects data via direct observation of a person while she interacts with a digital product, such as a citizen science website. The test participant verbalizes her thoughts while using the website or application; the moderator follows the participant and captures quantitative measurement of the participant's confidence of success as she advances through the citizen science project. Over 15 years of usability testing, we have observed that users who do not report a consistent sense of progress are likely to abandon a website after as few as three unrewarding interactions. Since citizen science is also a voluntary activity, ensuring seamless interaction for users is mandatory. Usability studies conducted on citizen science websites demonstrate that project teams frequently underestimate a user's need for context and ease of use. Without usability testing, risks to online citizen science projects include high bounce rate (users leave the website without taking any action), abandonment (of the website, tutorials, registration), misunderstanding instructions (causing disorientation and erroneous conclusions), and ultimately, underperforming projects.

  2. Pattern mining of user interaction logs for a post-deployment usability evaluation of a radiology PACS client.

    PubMed

    Jorritsma, Wiard; Cnossen, Fokie; Dierckx, Rudi A; Oudkerk, Matthijs; van Ooijen, Peter M A

    2016-01-01

    To perform a post-deployment usability evaluation of a radiology Picture Archiving and Communication System (PACS) client based on pattern mining of user interaction log data, and to assess the usefulness of this approach compared to a field study. All user actions performed on the PACS client were logged for four months. A data mining technique called closed sequential pattern mining was used to automatically extract frequently occurring interaction patterns from the log data. These patterns were used to identify usability issues with the PACS. The results of this evaluation were compared to the results of a field study based usability evaluation of the same PACS client. The interaction patterns revealed four usability issues: (1) the display protocols do not function properly, (2) the line measurement tool stays active until another tool is selected, rather than being deactivated after one use, (3) the PACS's built-in 3D functionality does not allow users to effectively perform certain 3D-related tasks, (4) users underuse the PACS's customization possibilities. All usability issues identified based on the log data were also found in the field study, which identified 48 issues in total. Post-deployment usability evaluation based on pattern mining of user interaction log data provides useful insights into the way users interact with the radiology PACS client. However, it reveals few usability issues compared to a field study and should therefore not be used as the sole method of usability evaluation. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  3. Comparison of two kinds of interface, based on guided navigation or usability principles, for improving the adoption of computerized decision support systems: application to the prescription of antibiotics

    PubMed Central

    Tsopra, Rosy; Jais, Jean-Philippe; Venot, Alain; Duclos, Catherine

    2014-01-01

    Context It is important to consider the way in which information is presented by the interfaces of clinical decision support systems, to favor the adoption of these systems by physicians. Interface design can focus on decision processes (guided navigation) or usability principles. Objective The aim of this study was to compare these two approaches in terms of perceived usability, accuracy rate, and confidence in the system. Materials and methods We displayed clinical practice guidelines for antibiotic treatment via two types of interface, which we compared in a crossover design. General practitioners were asked to provide responses for 10 clinical cases and the System Usability Scale (SUS) for each interface. We assessed SUS scores, the number of correct responses, and the confidence level for each interface. Results SUS score and percentage confidence were significantly higher for the interface designed according to usability principles (81 vs 51, p=0.00004, and 88.8% vs 80.7%, p=0.004). The percentage of correct responses was similar for the two interfaces. Discussion/conclusion The interface designed according to usability principles was perceived to be more usable and inspired greater confidence among physicians than the guided navigation interface. Consideration of usability principles in the construction of an interface—in particular ‘effective information presentation’, ‘consistency’, ‘efficient interactions’, ‘effective use of language’, and ‘minimizing cognitive load’—seemed to improve perceived usability and confidence in the system. PMID:24008427

  4. Travel Services, Levels 2-4. Travel Services (Field Operations), Levels 2-4. National Vocational Qualifications.

    ERIC Educational Resources Information Center

    Business and Technology Education Council, London (England).

    Britain's National Vocational Qualifications (NVQs) are work qualifications that measure what an employee or potential employee can do as well as how much he or she knows and understands about a particular job. Used as written proof of usable workplace skills that can be put to profitable use by an employer, NVQs range from basic Level 1, for…

  5. Using Heuristic Evaluation to Improve Sepsis Alert Usability.

    PubMed

    Pertiwi, Ariani Arista Putri; Fraczkowski, Dan; Stogis, Sheryl L; Lopez, Karen Dunn

    2018-06-01

    Sepsis, life-threatening organ dysfunction in response to infection, is an alarmingly common and aggressive illness in US hospitals, especially for intensive care patients. Preventing sepsis deaths rests on the clinicians' ability to promptly recognize and treat sepsis. To aid early recognition, many organizations have employed clinician-facing electronic sepsis alert systems. However, the effectiveness of the alert relies on heavily on the visual interface, textual information, and overall usability. This article reports a usability inspection of a sepsis alert system. The authors found violations in 12 of the 14 usability principles and promote use of this method in practice to systematically identify usability problems. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. Field Evaluation of Programmable Thermostats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sachs, O.; Tiefenbeck, V.; Duvier, C.

    2012-12-01

    Prior research suggests that poor programmable thermostats usability may prevent their effective use to save energy. We hypothesized that home occupants with a high-usability thermostats would be more likely to use them to save energy than people with a basic thermostat. We randomly installed a high-usability thermostat in half the 77 apartments of an affordable housing complex, installing a basic thermostat in the other half. During the heating season, we collected space temperature and furnace on-off data to evaluate occupant interaction with the thermostats, foremost nighttime setbacks. We found that thermostat usability did not influence energy-saving behaviors, finding no significantmore » difference in temperature maintained among apartments with high- and low-usability thermostats.« less

  7. Farmers, streams, information, and money: does informing farmers about riparian management have any effect?

    PubMed

    Rhodes, Heather M; Leland, Louis S; Niven, Brian E

    2002-11-01

    We assessed relationships between the extent to which farmers reported exposure to relevant information and their attitudes towards, knowledge about, and degree of adoption of riparian management strategies. We also examined associations between knowledge of, or receipt of, financial assistance for riparian fencing/planting and intentions for and extent of adoption of this strategy. A mail survey of 718 pastoral farmers in Otago and Southland in New Zealand [294 surveys returned (41%)] yielded 279 usable questionnaires. Indices were developed to reflect range and frequency of information use and range of practices adopted. Attitudes were measured using Likert-type responses to 11 statements, and knowledge as a score on a ten-question true/false test. Positive relationships between information and the three main response variables (attitude, knowledge, and adoption) were weak but significant and systematic. These associations remained significant when important demographic and farm characteristics were taken into account. Informed farmers were more likely to report intentions to carry out riparian fencing or planting within the next year. Farmers who were aware that funding was available were also more likely to state this intention, independent of information level. The reported extent to which waterways had been fenced to exclude stock was related to receipt of funding, but not to information level. Financial factors were the most influential barrier preventing adoption of permanent fencing. Our research shows a positive correlation between the receipt of information and funding and the adoption of specific riparian management measures.

  8. Usability Evaluation of Multimedia Courseware (MEL-SindD)

    NASA Astrophysics Data System (ADS)

    Yussof, Rahmah Lob; Badioze Zaman, Halimah

    Constructive evaluations on any software are needed to ensure the effectiveness and usability of the software. This assesment on the multimedia courseware is part of the researcher's study towards the development and usability of the early reading software for students with Down Syndrome (MEL-SindD). This paper will discuss the usability assesment of this courseware, the methods used for the evaluation as well as suitable approaches that can be deployed to evaluate the courseware effectiveness to disabled children.

  9. A Usability Study of Users’ Perceptions Toward a Multimedia Computer-Assisted Learning Tool for Neuroanatomy

    PubMed Central

    Gould, Douglas J.; Terrell, Mark A.; Fleming, Jo

    2015-01-01

    This usability study evaluated users’ perceptions of a multimedia prototype for a new e-learning tool: Anatomy of the Central Nervous System: A Multimedia Course. Usability testing is a collection of formative evaluation methods that inform the developmental design of e-learning tools to maximize user acceptance, satisfaction, and adoption. Sixty-two study participants piloted the prototype and completed a usability questionnaire designed to measure two usability properties: program need and program applicability. Statistical analyses were used to test the hypothesis that the multimedia prototype was well designed and highly usable, it was perceived as: 1) highly needed across a spectrum of educational contexts, 2) highly applicable in supporting the pedagogical processes of teaching and learning neuroanatomy, and 3) was highly usable by all types of users. Three independent variables represented user differences: level of expertise (faculty vs. student), age, and gender. Analysis of the results supports the research hypotheses that the prototype was designed well for different types of users in various educational contexts and for supporting the pedagogy of neuroanatomy. In addition, the results suggest that the multimedia program will be most useful as a neuroanatomy review tool for health-professions students preparing for licensing or board exams. This study demonstrates the importance of integrating quality properties of usability with principles of human learning during the instructional design process for multimedia products. PMID:19177405

  10. U.S.A.B.I.L.I.T.Y. Framework for Older Adults.

    PubMed

    Caboral-Stevens, Meriam; Whetsell, Martha V; Evangelista, Lorraine S; Cypress, Brigitte; Nickitas, Donna

    2015-01-01

    The purpose of the current study was to present a framework to determine potential usability of health websites by older adults. Review of the literature showed paucity of nursing theory related to the use of technology and usability, particularly in older adults. The Roy Adaptation Model, a widely used nursing theory, was chosen to provide framework for the new model. Technology constructs from the Technology Acceptance Model and United Theory of Acceptance and Use of Technology and behavioral control construct from the Theory of Planned Behavior were integrated into the construction of the derived model. The Use of Technology for Adaptation by Older Adults and/or Those With Limited Literacy (U.S.A.B.I.L.I.T.Y.) Model was constructed from the integration of diverse theoretical/conceptual perspectives. The four determinants of usability in the conceptual model include (a) efficiency, (b) learnability, (c) perceived user experience, and (d) perceived control. Because of the lack of well-validated survey questionnaires to measure these determinants, a U.S.A.B.I.L.I.T.Y. Survey was developed. A panel of experts evaluated face and content validity of the new instrument. Internal consistency of the new instrument was 0.96. Usability is key to accepting technology. The derived U.S.A.B.I.L.I.T.Y. framework could serve as a guide for nurses in formative evaluation of technology. Copyright 2015, SLACK Incorporated.

  11. A study of the use of vibration and stress wave sensing for the detection of bearing failure

    NASA Technical Reports Server (NTRS)

    Ensor, L. C.; Feng, C. C.

    1975-01-01

    Results from an experimental study of vibrations and stress waves emitted from ball bearings are presented. Fatique tests were run with both high quality bearings and man faulted bearings, all of one size. Tests were instrumented with different sensors to detect the noises from 10 Hz to 1 MHz. Frequency spectrum plots are presented. The modulation characteristics of the ultrasonic noises were analyzed, and acoustic emission type measurements were conducted. Results are presented which show that there are usable acoustic signal levels even beyond 500 KHz. These signal levels are modulated by a low frequency carrier which is a function of the stress loading and acoustic transmissibility. The results were correlated to fault size in the bearings. The correlation shows that the sensor used for signals from 100 KHz to 1 MHz gave the best sensitivity and detected the generation of very small spalls or pits.

  12. Determining Usability Versus Cost and Yields of a Regional Transport

    NASA Technical Reports Server (NTRS)

    Gvozdenovic, Slobodan

    1999-01-01

    Regional transports are designed to operate on air networks having the basic characteristics of short trip distances and low density passengers/cargo, i.e. small numbers of passengers per flight. Regional transports passenger capacity is from 10 to 100 seats and operate on routes from 350 to 1000 nautical miles (nm). In order to meet passenger requirements providing low fares and high or required number of frequencies, airlines must constantly monitor operational costs and keep them low. It is obvious that costs of operating aircraft must be lower than yield obtained by transporting passengers and cargo. The requirement to achieve favorable yield/cost ratio must provide the answer to the question of which aircraft will best meet a specific air network (Simpson, 1972). An air network is defined by the number of services, the trip distance of each service, and the number of flights (frequencies) per day and week.

  13. Designing Telemedicine Systems for Geriatric Patients: A Review of the Usability Studies.

    PubMed

    Narasimha, Shraddhaa; Madathil, Kapil Chalil; Agnisarman, Sruthy; Rogers, Hunter; Welch, Brandon; Ashok, Aparna; Nair, Aswathi; McElligott, James

    2017-06-01

    One area where telemedicine may prove to be highly effective is in providing medical care to the geriatric population, an age group predicted to account for 20% of the population in the near future. However, even though telemedicine has certain advantages, the usability of these systems with this population merits investigation. This article reviews the literature published from 2000 to 2016 with the goal of analyzing the characteristics of usability-related studies conducted using geriatric participants and the subsequent usability challenges identified. Articles were found using Web of Knowledge and PubMed citation indexing portals using the keywords (1) Telemedicine* AND Geriatrics* (2) Telemedicine* AND Usability* (3) Telemedicine* AND Usability* AND Older Adults*. A total of 297 articles were obtained from the initial search. After further detailed screening, 16 articles were selected for review based on the inclusion criteria. Of these, 60% of the studies focused on the overall usability of telemedicine systems; 6.25% focused on the usability of a telepresence robot; 12.5% compared a face-to-face medical consultation with the use of telemedicine systems, and 25% focused on the study of other aspects of telemedicine in addition to its usability. Findings reported in the studies included high patient satisfaction with telemedicine in 31.25%, whereas another 31.25% indicated a high acceptance of this method of medical consultation. Care coordination in 6.25% of the studies; confidence in telemedicine in 6.25%; trust, privacy, and reliability in 6.25%; and increased convenience when compared to personal visits in 18.75% were also reported. This review suggests limited research providing scientifically valid and reproducible usability evaluation at various stages of telemedicine system development. Telemedicine system designers need to consider the age-related issues in cognition, perception, and behavior of geriatric patients while designing telemedicine applications. Future directions for research were developed based on the limitations as well as other results found in this systematic review.

  14. Usability of ocean-bottom seismograms for broadband waveform tomography

    NASA Astrophysics Data System (ADS)

    Eibl, Eva P. S.; Sigloch, Karin

    2013-04-01

    Recordings made by broadband seismometers on the ocean-bottom are generally noisier than recordings of land stations using the same sensor type. The primary reason is that oceanic recordings are more affected by microseismic noise, which originates in the oceans. A similar drawback applies to data from stations on oceanic islands. The frequency band between 0.05 Hz and 0.2 Hz is most affected by microseismic noise -- unfortunately a large overlap with the band that is most useful in highly-resolving body-wave tomography when using land stations. On the other hand, waveform inversion methods, unlike traditional ray theory, do not necessarily depend on the availability of clean, pulse-like broadband signals across the entire frequency range. For example in finite-frequency tomography, the method of our choice, modelling procedures permit the exclusion of unusable frequency bands on a case-by-case basis. Hence we investigate to what extent seismograms from the ocean-bottom and from island stations can be used for broadband waveform inversion of teleseismic P-waves, as compared to continental land stations. We have re-analyzed data from one of the largest onshore-offshore, broadband, long-term seismological experiment to date: the Hawaiian PLUME project (Wolfe et al. 2009, Laske 2009). The data quality was studied in eight overlapping frequency bands (dominant periods between 30.0 s and 2.7 s), for year-long records from 62 ocean-bottom stations (January 2005 - June 2007), complemented by seismograms from 74 regional island stations and 236 continental stations from four different networks on the Pacific-rim, recorded in the same time frame. P-wave seismograms from 103 earthquakes of moment magnitude 6.2 and above, recorded at epicentral distances of 32° to 85° to Hawaii were assessed in this study. The quality of the recorded data was evaluated by calculating the cross-correlation coefficient between the first 1.5 dominant periods of real and predicted waveforms, in eight frequency passbands and on the broadband waveform, after careful correction for source parameters and source time function (Sigloch and Nolet 2006). As expected, permanent continental stations were quieter than permanent island stations in the Pacific, (independent of frequency band), and island stations were quieter than ocean-bottom stations. Relative data quality for both types of oceanic stations is lowest for dominant periods between 11s and 3 s. We present statistics for the fraction of usable data, as a function of station type, frequency band, and sensor type. In the lowest frequency band 55%, 71% and 90% of the data recorded by the PLUME stations, island stations and land stations, respectively, can be used for seismic tomography. These values drop with increasing frequency, to a minimum of 12% for the island stations, 8% for OBS stations and 33% for the land stations. We also compare data quality by OBS sensor type (Nanometrics T-40, Nanometrics T-240, Güralp CMG-3T). We find that frequency bands around 2.7 s and between 20.0 to 30.0 s have low noise levels but have not been used for tomography by the project PIs. A multiple-frequency waveform inversion including these additional bands and wave paths, as well as a larger number of earthquakes (101 versus 97 and 59 used in the original studies by Wolfe et al. 2009 and Wolfe et al. 2011) should be able to improve the resolution of the velocity structure in the upper and lower mantle beneath the Hawaiian hotspot. References: Laske, G., Collins, J. A., Wolfe, C. J., Solomon, S. C., Detrick, R. S., Orcutt, J. A., Bercovici, D., Hauri, E. H. (2009). Probing the Hawaiian hotspot with new broadband ocean bottom instruments. Eos Trans. AGU, 90(41), 362-363. Sigloch, K., & Nolet, G. (2006). Measuring finite-frequency body-wave amplitudes and traveltimes. Geophysical Journal International, 167(1), 271-287, doi:10.1111/j.1365-246X.2006.03116.x Wolfe, C.J, Solomon, S.C., Laske G., Collins, J.A., Detrick, R.S., Orcutt, J.A., Bercovici, D., and Hauri, E.H. (2009) Mantle shear-wave velocity structure beneath the Hawaiian hot spot. Science (New York, N.Y.), 326(5958), 1388-1390. Wolfe, C.J, Solomon, S.C., Laske G., Collins, J.A., Detrick, R.S., Orcutt, J.A., Bercovici, D., and Hauri, E.H. (2011) Mantle P-wave velocity structure beneath the Hawaiian hotspot. Earth and Planetary Science Letters, 303(3-4), 267-280.

  15. Effect of font size, italics, and colour count on web usability.

    PubMed

    Bhatia, Sanjiv K; Samal, Ashok; Rajan, Nithin; Kiviniemi, Marc T

    2011-04-01

    Web usability measures the ease of use of a website. This study attempts to find the effect of three factors - font size, italics, and colour count - on web usability. The study was performed using a set of tasks and developing a survey questionnaire. We performed the study using a set of human subjects, selected from the undergraduate students taking courses in psychology. The data computed from the tasks and survey questionnaire were statistically analysed to find if there was any effect of font size, italics, and colour count on the three web usability dimensions. We found that for the student population considered, there was no significant effect of font size on usability. However, the manipulation of italics and colour count did influence some aspects of usability. The subjects performed better for pages with no italics and high italics compared to moderate italics. The subjects rated the pages that contained only one colour higher than the web pages with four or six colours. This research will help web developers better understand the effect of font size, italics, and colour count on web usability in general, and for young adults, in particular.

  16. Web usability testing with a Hispanic medically underserved population.

    PubMed

    Moore, Mary; Bias, Randolph G; Prentice, Katherine; Fletcher, Robin; Vaughn, Terry

    2009-04-01

    Skilled website developers value usability testing to assure user needs are met. When the target audience differs substantially from the developers, it becomes essential to tailor both design and evaluation methods. In this study, researchers carried out a multifaceted usability evaluation of a website (Healthy Texas) designed for Hispanic audiences with lower computer literacy and lower health literacy. METHODS INCLUDED: (1) heuristic evaluation by a usability engineer, (2) remote end-user testing using WebEx software; and (3) face-to-face testing in a community center where use of the website was likely. Researchers found standard usability testing methods needed to be modified to provide interpreters, increased flexibility for time on task, presence of a trusted intermediary such as a librarian, and accommodation for family members who accompanied participants. Participants offered recommendations for website redesign, including simplified language, engaging and relevant graphics, culturally relevant examples, and clear navigation. User-centered design is especially important when website developers are not representative of the target audience. Failure to conduct appropriate usability testing with a representative audience can substantially reduce use and value of the website. This thorough course of usability testing identified improvements that benefit all users but become crucial when trying to reach an underserved audience.

  17. Mobile Health Applications, in the Absence of an Authentic Regulation, Does the Usability Score Correlate with a Better Medical Reliability?

    PubMed

    Yasini, Mobin; Marchand, Guillaume

    2015-01-01

    Health-related mobile applications (apps) have been shown to improve the quality of health and patient care. Their use in clinical and health-related environments is becoming more considerable. The number of health-related apps available for download has considerably increased, while the regulatory position of this new industry is not well known. Despite this lack of regulation, measuring the usability score of these apps is not difficult. We compared two samples of twenty health-related applications each. One of the samples contained the apps with top-rated usability scores, and the other contained the apps with lowest-rated usability scores. We found that a good usability score correlates with a better medical reliability of the app's content (p<0.005). In the period in which a valid regulation is still lacking, calculation and attribution of usability scores to mobile applications could be used to identify apps with better medical quality. However, the usability score method ought to be rigorous and should not be rounded off with a simple five stars rating (as is the case in the classic app stores).

  18. Measuring the Usability of Augmented Reality e-Learning Systems: A User-Centered Evaluation Approach

    NASA Astrophysics Data System (ADS)

    Pribeanu, Costin; Balog, Alexandru; Iordache, Dragoş Daniel

    The development of Augmented Reality (AR) systems is creating new challenges and opportunities for the designers of e-learning systems. The mix of real and virtual requires appropriate interaction techniques that have to be evaluated with users in order to avoid usability problems. Formative usability aims at finding usability problems as early as possible in the development life cycle and is suitable to support the development of such novel interactive systems. This work presents an approach to the user-centered usability evaluation of an e-learning scenario for Biology developed on an Augmented Reality educational platform. The evaluation has been carried on during and after a summer school held within the ARiSE research project. The basic idea was to perform usability evaluation twice. In this respect, we conducted user testing with a small number of students during the summer school in order to get a fast feedback from users having good knowledge in Biology. Then, we repeated the user testing in different conditions and with a relatively larger number of representative users. In this paper we describe both experiments and compare the usability evaluation results.

  19. Effect of font size, italics, and colour count on web usability

    PubMed Central

    Samal, Ashok; Rajan, Nithin; Kiviniemi, Marc T.

    2013-01-01

    Web usability measures the ease of use of a website. This study attempts to find the effect of three factors – font size, italics, and colour count – on web usability. The study was performed using a set of tasks and developing a survey questionnaire. We performed the study using a set of human subjects, selected from the undergraduate students taking courses in psychology. The data computed from the tasks and survey questionnaire were statistically analysed to find if there was any effect of font size, italics, and colour count on the three web usability dimensions. We found that for the student population considered, there was no significant effect of font size on usability. However, the manipulation of italics and colour count did influence some aspects of usability. The subjects performed better for pages with no italics and high italics compared to moderate italics. The subjects rated the pages that contained only one colour higher than the web pages with four or six colours. This research will help web developers better understand the effect of font size, italics, and colour count on web usability in general, and for young adults, in particular. PMID:24358055

  20. 36 CFR 1193.21 - Accessibility, usability, and compatibility.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Accessibility, usability, and compatibility. 1193.21 Section 1193.21 Parks, Forests, and Public Property ARCHITECTURAL AND TRANSPORTATION... Accessibility, usability, and compatibility. Where readily achievable, telecommunications equipment and customer...

  1. 36 CFR 1193.21 - Accessibility, usability, and compatibility.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 36 Parks, Forests, and Public Property 3 2011-07-01 2011-07-01 false Accessibility, usability, and compatibility. 1193.21 Section 1193.21 Parks, Forests, and Public Property ARCHITECTURAL AND TRANSPORTATION... Accessibility, usability, and compatibility. Where readily achievable, telecommunications equipment and customer...

  2. 36 CFR 1193.21 - Accessibility, usability, and compatibility.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 36 Parks, Forests, and Public Property 3 2012-07-01 2012-07-01 false Accessibility, usability, and compatibility. 1193.21 Section 1193.21 Parks, Forests, and Public Property ARCHITECTURAL AND TRANSPORTATION... Accessibility, usability, and compatibility. Where readily achievable, telecommunications equipment and customer...

  3. 36 CFR 1193.21 - Accessibility, usability, and compatibility.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 36 Parks, Forests, and Public Property 3 2014-07-01 2014-07-01 false Accessibility, usability, and compatibility. 1193.21 Section 1193.21 Parks, Forests, and Public Property ARCHITECTURAL AND TRANSPORTATION... Accessibility, usability, and compatibility. Where readily achievable, telecommunications equipment and customer...

  4. Usability testing of a prototype multi-user telehealth kiosk.

    PubMed

    Courtney, Karen L; Matthews, Judith T; McMillan, Julie M; Person Mecca, Laurel; Smailagic, Asim; Siewiorek, Daniel

    2015-01-01

    The overall purpose of this study was to learn how community-dwelling older adults would interact with our prototype multi-user telehealth kiosk and their views about its usability. Seven subjects participated in laboratory-based usability sessions to evaluate the physical design, appearance, functionality and perceived ease of use of a multi-user telehealth kiosk prototype. During usability testing participants recommended 18 new features (29% of comments), identified 15 software errors (23% of comments) and 29 user interface errors (47% of comments).

  5. Development of the Lupus Interactive Navigator as an Empowering Web-Based eHealth Tool to Facilitate Lupus Management: Users Perspectives on Usability and Acceptability.

    PubMed

    Neville, Carolyn; Da Costa, Deborah; Rochon, Murray; Peschken, Christine A; Pineau, Christian A; Bernatsky, Sasha; Keeling, Stephanie; Avina-Zubieta, Antonio; Lye, Elizabeth; Eng, Davy; Fortin, Paul R

    2016-05-30

    Systemic Lupus Erythematosus (SLE) is a serious, complex, and chronic illness. Similar to most other chronic illness states, there is great interest in helping persons with SLE engage in their disease management. The objectives of this study were to (1) develop the Lupus Interactive Navigator (LIN), a web-based self-management program for persons with SLE, and (2) test the LIN for usability and acceptability. The LIN development platform was based on the results of preliminary comprehensive needs assessments and adapted from the Oncology Interactive Navigator, a web-based tool developed for persons with cancer. Medical researchers, writers, designers, and programmers worked with clinical experts and persons with SLE to develop content for the LIN. Usability and acceptability of the LIN was tested on individuals with SLE meeting American College of Rheumatology criteria, who were recruited from five Canadian SLE clinics. Participants were provided with access to the LIN and were asked to use it over a two-week period. Following the testing period, participants were contacted for a 30-minute telephone interview to assess usability and acceptability. The content for the LIN was subdivided into six primary information topics with interview videos featuring rheumatologists, allied health professionals, and persons with SLE. Usability and acceptability of the LIN was tested on 43 females with SLE. Of these, 37 (86%) completed telephone interviews. The average age was 43.6 (SD 15.9) years and disease duration averaged 14.1 (SD 10.8) years. Median time spent on LIN was 16.3 (interquartile range [IQR]:13.7, 53.5) minutes and median number of sessions was 2 (IQR: 1, 3). Overall, Likert ratings (0=strongly disagree; 7=strongly agree) of website usability and content were very high, with 75% scoring >6 out of 7 on all items. All participants agreed that LIN was easy to use, would recommend it to others with SLE, and would refer to it for future questions about SLE. Very high ratings were also given to relevancy, credibility, and usefulness of the information provided. Overall, 73% of the participants rated all topics helpful to very helpful. Participants who reported more prior knowledge about SLE rated items regarding improvement in knowledge and helpfulness relatively lower than persons with less prior knowledge. Most participants commented that the LIN would be very useful to those newly diagnosed with SLE. Minor revisions were recommended. This study furthers the understanding of the needs in the SLE community and delivers a unique eHealth tool to promote self-management in persons with SLE. The LIN was found to be highly acceptable in content and usability. The information provided on LIN may be most helpful for individuals with less experience with the disease, such as those newly diagnosed, indicating the need to tailor the content for persons with more SLE experience.

  6. The McMaster Optimal Aging Portal: Usability Evaluation of a Unique Evidence-Based Health Information Website.

    PubMed

    Barbara, Angela M; Dobbins, Maureen; Haynes, R Brian; Iorio, Alfonso; Lavis, John N; Raina, Parminder; Levinson, Anthony J

    2016-05-11

    Increasingly, older adults and their informal caregivers are using the Internet to search for health-related information. There is a proliferation of health information online, but the quality of this information varies, often based on exaggerated or dramatic findings, and not easily comprehended by consumers. The McMaster Optimal Aging Portal (Portal) was developed to provide Internet users with high-quality evidence about aging and address some of these current limitations of health information posted online. The Portal includes content for health professionals coming from three best-in-class resources (MacPLUS, Health Evidence, and Health Systems Evidence) and four types of content specifically prepared for the general public (Evidence Summaries, Web Resource Ratings, Blog Posts, and Twitter messages). Our objectives were to share the findings of the usability evaluation of the Portal with particular focus on the content features for the general public and to inform designers of health information websites and online resources for older adults about key usability themes. Data analysis included task performance during usability testing and qualitative content analyses of both the usability sessions and interviews to identify core themes. A total of 37 participants took part in 33 usability testing sessions and 21 focused interviews. Qualitative analysis revealed common themes regarding the Portal's strengths and challenges to usability. The strengths of the website were related to credibility, applicability, browsing function, design, and accessibility. The usability challenges included reluctance to register, process of registering, searching, terminology, and technical features. The study reinforced the importance of including end users during the development of this unique, dynamic, evidence-based health information website. The feedback was applied to iteratively improve website usability. Our findings can be applied by designers of health-related websites.

  7. The McMaster Optimal Aging Portal: Usability Evaluation of a Unique Evidence-Based Health Information Website

    PubMed Central

    Dobbins, Maureen; Haynes, R. Brian; Iorio, Alfonso; Lavis, John N; Raina, Parminder

    2016-01-01

    Background Increasingly, older adults and their informal caregivers are using the Internet to search for health-related information. There is a proliferation of health information online, but the quality of this information varies, often based on exaggerated or dramatic findings, and not easily comprehended by consumers. The McMaster Optimal Aging Portal (Portal) was developed to provide Internet users with high-quality evidence about aging and address some of these current limitations of health information posted online. The Portal includes content for health professionals coming from three best-in-class resources (MacPLUS, Health Evidence, and Health Systems Evidence) and four types of content specifically prepared for the general public (Evidence Summaries, Web Resource Ratings, Blog Posts, and Twitter messages). Objective Our objectives were to share the findings of the usability evaluation of the Portal with particular focus on the content features for the general public and to inform designers of health information websites and online resources for older adults about key usability themes. Methods Data analysis included task performance during usability testing and qualitative content analyses of both the usability sessions and interviews to identify core themes. Results A total of 37 participants took part in 33 usability testing sessions and 21 focused interviews. Qualitative analysis revealed common themes regarding the Portal’s strengths and challenges to usability. The strengths of the website were related to credibility, applicability, browsing function, design, and accessibility. The usability challenges included reluctance to register, process of registering, searching, terminology, and technical features. Conclusions The study reinforced the importance of including end users during the development of this unique, dynamic, evidence-based health information website. The feedback was applied to iteratively improve website usability. Our findings can be applied by designers of health-related websites. PMID:27170443

  8. Usability of a New Writing Assistive Device for Persons with Cervical Spinal Cord Injury.

    PubMed

    Lim, MyungJoon; Park, Jiyoung; Lee, Kuem Ju; Kweon, Hyosun; Kim, Byungchul; Cho, Kyujin; Choi, Hyun

    2015-01-01

    The hand function for persons with cervical spinal cord injury (PCSCI) is most frequently cause difficulties in leading normal lives. The purpose of this study was to test the usability of a new writing assistive device (NWAD) for PCSCI. To access its usability, the authors design usability testing method and test the NWAD to five individuals with cervical spinal cord injury. From the usability testing, we have found number of issues that lead us to key design concept about developing the NWAD. The NWAD will be redesigned based on the result of the present study. We expect that the NWAD will help PCSCI use their affected hand better and improve the level of independence and quality of life.

  9. A Usability Case Study Using TREC and ZPRISE.

    ERIC Educational Resources Information Center

    Downey, Laura L.; Tice, Dawn M.

    1999-01-01

    Examines the challenges involved in conducting an informal usability case study based on the introduction of a new information-retrieval system to experienced users. Identifies problems users were having with TREC (Text Retrieval Conference) and examines the usability of the new ZPRISE interface. (Author/LRW)

  10. 7 CFR 42.102 - Definitions, general.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... the serviceability, including appearance as well as usability, of the container for its intended.... A defect that seriously affects, or is likely to seriously affect, the usability of the container... materially affect, the usability of the container for its intended purpose. (c) Minor defect. A defect that...

  11. Dimensions for hearing-impaired mobile application usability model

    NASA Astrophysics Data System (ADS)

    Nathan, Shelena Soosay; Hussain, Azham; Hashim, Nor Laily; Omar, Mohd Adan

    2017-10-01

    This paper discuss on the dimensions that has been derived for the hearing-impaired mobile applications usability model. General usability model consist of general dimension for evaluating mobile application however requirements for the hearing-impaired are overlooked and often scanted. This led towards mobile application developed for the hearing-impaired are left unused. It is also apparent that these usability models do not consider accessibility dimensions according to the requirement of the special users. This complicates the work of usability practitioners as well as academician that practices research usability when application are developed for the specific user needs. To overcome this issue, dimension chosen for the hearing-impaired are ensured to be align with the real need of the hearing-impaired mobile application. Besides literature studies, requirements for the hearing-impaired mobile application have been identified through interview conducted with hearing-impaired mobile application users that were recorded as video outputs and analyzed using Nvivo. Finally total of 6 out of 15 dimensions gathered are chosen for the proposed model and presented.

  12. Developing Analytical Inspection Criteria for Health IT Personnel with Minimum Training in Cognitive Ergonomics: A Practical Solution to EHR Improving EHR Usability

    PubMed Central

    Zhang, Zhen; Franklin, Amy; Walji, Muhammad; Zhang, Jiajie; Gong, Yang

    2014-01-01

    EHR usability has been identified as a major barrier to care quality optimization. One major challenge of improving EHR usability is the lack of systematic training in usability or cognitive ergonomics for EHR designers/developers in the vendor community and EHR analysts making significant configurations in healthcare organizations. A practical solution is to provide usability inspection tools that can be easily operationalized by EHR analysts. This project is aimed at developing a set of usability tools with demonstrated validity and reliability. We present a preliminary study of a metric for cognitive transparency and an exploratory experiment testing its validity in predicting the effectiveness of action-effect mapping. Despite the pilot nature of both, we found high sensitivity and specificity of the metric and higher response accuracy within a shorter time for users to determine action-effect mappings in transparent user interface controls. We plan to expand the sample size in our empirical study. PMID:25954439

  13. Usability and acceptability of balance exergames in older adults: A scoping review.

    PubMed

    Nawaz, Ather; Skjæret, Nina; Helbostad, Jorunn Lægdheim; Vereijken, Beatrix; Boulton, Elisabeth; Svanaes, Dag

    2016-12-01

    Serious games (exergames) have the potential to be effective for postural balance and increasing muscle strength. Several games have been developed to increase physical fitness and balance among older adults. However, it is unclear to which degree usability and acceptability of exergames for older adults have been evaluated. The aim of this study was to summarize usability evaluation and acceptability of studies in older adults. We conducted a scoping review on studies focusing on usability of exergames for older adults. The result shows that older adults consider usability and acceptability of exercise video games good. The review shows that longitudinal studies mainly use off-the-shelf exergame and evaluated game effectiveness and acceptability, whereas cross-sectional studies focus on interactional experience. Studies varied in their approaches to measure usability and acceptability of exergames for older adults. There is a need for a systematic developmental approach to involve older adults in development of exergames for longitudinal studies. © The Author(s) 2015.

  14. A usability evaluation toolkit for In-Vehicle Information Systems (IVISs).

    PubMed

    Harvey, Catherine; Stanton, Neville A; Pickering, Carl A; McDonald, Mike; Zheng, Pengjun

    2011-05-01

    Usability must be defined specifically for the context of use of the particular system under investigation. This specific context of use should also be used to guide the definition of specific usability criteria and the selection of appropriate evaluation methods. There are four principles which can guide the selection of evaluation methods, relating to the information required in the evaluation, the stage at which to apply methods, the resources required and the people involved in the evaluation. This paper presents a framework for the evaluation of usability in the context of In-Vehicle Information Systems (IVISs). This framework guides designers through defining usability criteria for an evaluation, selecting appropriate evaluation methods and applying those methods. These stages form an iterative process of design-evaluation-redesign with the overall aim of improving the usability of IVISs and enhancing the driving experience, without compromising the safety of the driver. Copyright © 2010 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  15. Usability and Culture as Two of the Value Criteria for Evaluating the Artifact

    NASA Astrophysics Data System (ADS)

    Kurosu, Masaaki

    In this paper, the conceptual framework of the Artifact Development Analysis (ADA) and its relationship to the usability engineering are outlined. The ADA analyses the significance of all artifacts including hardware, software, humanware and system. Its viewpoint extends both in temporal and spatial dimensions. In short, it deals with the diversity of the artifact and casts the questions "why it is so" and "why it is not so". In this respect, the ADA is related to the usability engineering as one of the value attitudes. The usability engineering puts emphasis on effectiveness and efficiency. The usability is not always the value criterion of highest importance and some people sometimes put more emphasis on other criteria such as the aesthetic aspect, the cost, etc. Based on the findings of ADA, we should focus on the extent where the usability can provide the core satisfaction and we should also summarize the guideline on how the artifact should be designed.

  16. A Method for Automated Detection of Usability Problems from Client User Interface Events

    PubMed Central

    Saadawi, Gilan M.; Legowski, Elizabeth; Medvedeva, Olga; Chavan, Girish; Crowley, Rebecca S.

    2005-01-01

    Think-aloud usability analysis provides extremely useful data but is very time-consuming and expensive to perform because of the extensive manual video analysis that is required. We describe a simple method for automated detection of usability problems from client user interface events for a developing medical intelligent tutoring system. The method incorporates (1) an agent-based method for communication that funnels all interface events and system responses to a centralized database, (2) a simple schema for representing interface events and higher order subgoals, and (3) an algorithm that reproduces the criteria used for manual coding of usability problems. A correction factor was empirically determining to account for the slower task performance of users when thinking aloud. We tested the validity of the method by simultaneously identifying usability problems using TAU and manually computing them from stored interface event data using the proposed algorithm. All usability problems that did not rely on verbal utterances were detectable with the proposed method. PMID:16779121

  17. Situated Usability Testing for Security Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Greitzer, Frank L.

    2011-03-02

    While usability testing is well established, assessing the usability of security software, tools, or methods deserves more careful consideration. It has been argued that dealing with security has become too difficult for individuals or organizations to manage effectively or to use conveniently. As difficult as it is for system administrators and developers to deal with, security is even more challenging for casual users. Indeed, it is much too easy for casual/home users to configure the security of their systems in non-optimal ways that leave their systems inadvertently insecure. This is exacerbated by the fact that casual users are focused onmore » matters other than security, and likely would prefer not even to think about security. This brief report argues that when security and/or privacy are part of the equation, traditional methods for usability testing should be re-considered. The purpose of this brief report is to argue for and outline a method associated with a new approach to usability testing for examining usable security issues.« less

  18. Usability in product design--the importance and need for systematic assessment models in product development--Usa-Design Model (U-D) ©.

    PubMed

    Merino, Giselle Schmidt Alves Díaz; Teixeira, Clarissa Stefani; Schoenardie, Rodrigo Petry; Merino, Eugenio Andrés Diáz; Gontijo, Leila Amaral

    2012-01-01

    In product design, human factors are considered as an element of differentiation given that today's consumer demands are increasing. Safety, wellbeing, satisfaction, health, effectiveness, efficiency, and other aspects must be effectively incorporated into the product development process. This work proposes a usability assessment model that can be incorporated as an assessment tool. The methodological approach is settled in two stages. First a literature review focus specifically on usability and developing user-centred products. After this, a model of usability named Usa-Design (U-D©) is presented. Consisted of four phases: understanding the use context, pre-preliminary usability assessment (efficiency/effectiveness/satisfaction); assessment of usability principles and results, U-D© features are modular and flexible, allowing principles used in Phase 3 to be changed according to the needs and scenario of each situation. With qualitative/quantitative measurement scales of easy understanding and application, the model results are viable and applicable throughout all the product development process.

  19. West Texas array experiment: Noise and source characterization of short-range infrasound and acoustic signals, along with lab and field evaluation of Intermountain Laboratories infrasound microphones

    NASA Astrophysics Data System (ADS)

    Fisher, Aileen

    The term infrasound describes atmospheric sound waves with frequencies below 20 Hz, while acoustics are classified within the audible range of 20 Hz to 20 kHz. Infrasound and acoustic monitoring in the scientific community is hampered by low signal-to-noise ratios and a limited number of studies on regional and short-range noise and source characterization. The JASON Report (2005) suggests the infrasound community focus on more broad-frequency, observational studies within a tactical distance of 10 km. In keeping with that recommendation, this paper presents a study of regional and short-range atmospheric acoustic and infrasonic noise characterization, at a desert site in West Texas, covering a broad frequency range of 0.2 to 100 Hz. To spatially sample the band, a large number of infrasound gauges was needed. A laboratory instrument analysis is presented of the set of low-cost infrasound sensors used in this study, manufactured by Inter-Mountain Laboratories (IML). Analysis includes spectra, transfer functions and coherences to assess the stability and range of the gauges, and complements additional instrument testing by Sandia National Laboratories. The IMLs documented here have been found reliably coherent from 0.1 to 7 Hz without instrument correction. Corrections were built using corresponding time series from the commercially available and more expensive Chaparral infrasound gauge, so that the corrected IML outputs were able to closely mimic the Chaparral output. Arrays of gauges are needed for atmospheric sound signal processing. Our West Texas experiment consisted of a 1.5 km aperture, 23-gauge infrasound/acoustic array of IMLs, with a compact, 12 m diameter grid-array of rented IMLs at the center. To optimize signal recording, signal-to-noise ratio needs to be quantified with respect to both frequency band and coherence length. The higher-frequency grid array consisted of 25 microphones arranged in a five by five pattern with 3 meter spacing, without spatial wind noise filtering hoses or pipes. The grid was within the distance limits of a single gauge's normal hose array, and data were used to perform a spatial noise correlation study. The highest correlation values were not found in the lower frequencies as anticipated, owing to a lack of sources in the lower range and the uncorrelated nature of wind noise. The highest values, with cross-correlation averages between 0.4 and 0.7 from 3 to 17 m between gauges, were found at night from 10 and 20 Hz due to a continuous local noise source and low wind. Data from the larger array were used to identify continuous and impulsive signals in the area that comprise the ambient noise field. Ground truth infrasound and acoustic, time and location data were taken for a highway site, a wind farm, and a natural gas compressor. Close-range sound data were taken with a single IML "traveler" gauge. Spectrograms and spectrum peaks were used to identify their source signatures. Two regional location techniques were also tested with data from the large array by using a propane cannon as a controlled, impulsive source. A comparison is presented of the Multiple Signal Classification Algorithm (MUSIC) to a simple, quadratic, circular wavefront algorithm. MUSIC was unable to effectively separate noise and source eignenvalues and eigenvectors due to spatial aliasing of the propane cannon signal and a lack of incoherent noise. Only 33 out of 80 usable shots were located by MUSIC within 100 m. Future work with the algorithm should focus on location of impulsive and continuous signals with development of methods for accurate separation of signal and noise eigenvectors in the presence of coherent noise and possible spatial aliasing. The circular wavefront algorithm performed better with our specific dataset and successfully located 70 out of 80 propane cannon shots within 100 m of the original location, 66 of which were within 20 m. This method has low computation requirements, making it well suited for real-time automated processing and smaller computers. Future research could focus on development of the method for an automated system and statistical impulsive noise filtering for higher accuracy.

  20. Parametric study of transport beam lines for electron beams accelerated by laser-plasma interaction

    NASA Astrophysics Data System (ADS)

    Scisciò, M.; Lancia, L.; Migliorati, M.; Mostacci, A.; Palumbo, L.; Papaphilippou, Y.; Antici, P.

    2016-03-01

    In the last decade, laser-plasma acceleration of high-energy electrons has attracted strong attention in different fields. Electrons with maximum energies in the GeV range can be laser-accelerated within a few cm using multi-hundreds terawatt (TW) lasers, yielding to very high beam currents at the source (electron bunches with up to tens-hundreds of pC in a few fs). While initially the challenge was to increase the maximum achievable electron energy, today strong effort is put in the control and usability of these laser-generated beams that still lack of some features in order to be used for applications where currently conventional, radio-frequency (RF) based, electron beam lines represent the most common and efficient solution. Several improvements have been suggested for this purpose, some of them acting directly on the plasma source, some using beam shaping tools located downstream. Concerning the latter, several studies have suggested the use of conventional accelerator magnetic devices (such as quadrupoles and solenoids) as an easy implementable solution when the laser-plasma accelerated beam requires optimization. In this paper, we report on a parametric study related to the transport of electron beams accelerated by laser-plasma interaction, using conventional accelerator elements and tools. We focus on both, high energy electron beams in the GeV range, as produced on petawatt (PW) class laser systems, and on lower energy electron beams in the hundreds of MeV range, as nowadays routinely obtained on commercially available multi-hundred TW laser systems. For both scenarios, our study allows understanding what are the crucial parameters that enable laser-plasma accelerators to compete with conventional ones and allow for a beam transport. We show that suitable working points require a tradeoff-combination between low beam divergence and narrow energy spread.

  1. A human-oriented framework for developing assistive service robots.

    PubMed

    McGinn, Conor; Cullinan, Michael F; Culleton, Mark; Kelly, Kevin

    2018-04-01

    Multipurpose robots that can perform a range of useful tasks have the potential to increase the quality of life for many people living with disabilities. Owing to factors such as high system complexity, as-yet unresolved research questions and current technology limitations, there is a need for effective strategies to coordinate the development process. Integrating established methodologies based on human-centred design and universal design, a framework was formulated to coordinate the robot design process over successive iterations of prototype development. An account is given of how the framework was practically applied to the problem of developing a personal service robot. Application of the framework led to the formation of several design goals which addressed a wide range of identified user needs. The resultant prototype solution, which consisted of several component elements, succeeded in demonstrating the performance stipulated by all of the proposed metrics. Application of the framework resulted in the development of a complex prototype that addressed many aspects of the functional and usability requirements of a personal service robot. Following the process led to several important insights which directly benefit the development of subsequent prototypes. Implications for Rehabilitation This research shows how universal design might be used to formulate usability requirements for assistive service robots. A framework is presented that guides the process of designing service robots in a human-centred way. Through practical application of the framework, a prototype robot system that addressed a range of identified user needs was developed.

  2. 7 CFR 42.102 - Definitions, general.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... freedom from defects which affect the serviceability, including appearance as well as usability, of the..., the usability of the container for its intended purpose. (b) Major defect. A defect that materially affects, or is likely to materially affect, the usability of the container for its intended purpose. (c...

  3. Evaluating Web Usability

    ERIC Educational Resources Information Center

    Snider, Jean; Martin, Florence

    2012-01-01

    Web usability focuses on design elements and processes that make web pages easy to use. A website for college students was evaluated for underutilization. One-on-one testing, focus groups, web analytics, peer university review and marketing focus group and demographic data were utilized to conduct usability evaluation. The results indicated that…

  4. Using participative inquiry in usability analysis to align a development team's mental model with its users' needs

    NASA Technical Reports Server (NTRS)

    Kneifel, A. A.; Guerrero, C.

    2003-01-01

    In this web site usability case study, two methods of participative inquiry are used to align a development team's objectives with their users' needs and to promote the team awareness of the benefit of qualitative usability analysis.

  5. 7 CFR 42.102 - Definitions, general.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... freedom from defects which affect the serviceability, including appearance as well as usability, of the..., the usability of the container for its intended purpose. (b) Major defect. A defect that materially affects, or is likely to materially affect, the usability of the container for its intended purpose. (c...

  6. 7 CFR 42.102 - Definitions, general.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... freedom from defects which affect the serviceability, including appearance as well as usability, of the..., the usability of the container for its intended purpose. (b) Major defect. A defect that materially affects, or is likely to materially affect, the usability of the container for its intended purpose. (c...

  7. 36 CFR § 1193.21 - Accessibility, usability, and compatibility.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 36 Parks, Forests, and Public Property 3 2013-07-01 2012-07-01 true Accessibility, usability, and compatibility. § 1193.21 Section § 1193.21 Parks, Forests, and Public Property ARCHITECTURAL AND... § 1193.21 Accessibility, usability, and compatibility. Where readily achievable, telecommunications...

  8. Interdisciplinary Development of an Improved Emergency Department Procedural Work Surface Through Iterative Design and Use Testing in Simulated and Clinical Environments.

    PubMed

    Zhang, Xiao C; Bermudez, Ana M; Reddy, Pranav M; Sarpatwari, Ravi R; Chheng, Darin B; Mezoian, Taylor J; Schwartz, Victoria R; Simmons, Quinneil J; Jay, Gregory D; Kobayashi, Leo

    2017-03-01

    A stable and readily accessible work surface for bedside medical procedures represents a valuable tool for acute care providers. In emergency department (ED) settings, the design and implementation of traditional Mayo stands and related surface devices often limit their availability, portability, and usability, which can lead to suboptimal clinical practice conditions that may affect the safe and effective performance of medical procedures and delivery of patient care. We designed and built a novel, open-source, portable, bedside procedural surface through an iterative development process with use testing in simulated and live clinical environments. The procedural surface development project was conducted between October 2014 and June 2016 at an academic referral hospital and its affiliated simulation facility. An interdisciplinary team of emergency physicians, mechanical engineers, medical students, and design students sought to construct a prototype bedside procedural surface out of off-the-shelf hardware during a collaborative university course on health care design. After determination of end-user needs and core design requirements, multiple prototypes were fabricated and iteratively modified, with early variants featuring undermattress stabilizing supports or ratcheting clamp mechanisms. Versions 1 through 4 underwent 2 hands-on usability-testing simulation sessions; version 5 was presented at a design critique held jointly by a panel of clinical and industrial design faculty for expert feedback. Responding to select feedback elements over several surface versions, investigators arrived at a near-final prototype design for fabrication and use testing in a live clinical setting. This experimental procedural surface (version 8) was constructed and then deployed for controlled usability testing against the standard Mayo stands in use at the study site ED. Clinical providers working in the ED who opted to participate in the study were provided with the prototype surface and just-in-time training on its use when performing bedside procedures. Subjects completed the validated 10-point System Usability Scale postshift for the surface that they had used. The study protocol was approved by the institutional review board. Multiple prototypes and recursive design revisions resulted in a fully functional, portable, and durable bedside procedural surface that featured a stainless steel tray and intuitive hook-and-lock mechanisms for attachment to ED stretcher bed rails. Forty-two control and 40 experimental group subjects participated and completed questionnaires. The median System Usability Scale score (out of 100; higher scores associated with better usability) was 72.5 (interquartile range [IQR] 51.3 to 86.3) for the Mayo stand; the experimental surface was scored at 93.8 (IQR 84.4 to 97.5 for a difference in medians of 17.5 (95% confidence interval 10 to 27.5). Subjects reported several usability challenges with the Mayo stand; the experimental surface was reviewed as easy to use, simple, and functional. In accordance with experimental live environment deployment, questionnaire responses, and end-user suggestions, the project team finalized the design specification for the experimental procedural surface for open dissemination. An iterative, interdisciplinary approach was used to generate, evaluate, revise, and finalize the design specification for a new procedural surface that met all core end-user requirements. The final surface design was evaluated favorably on a validated usability tool against Mayo stands when use tested in simulated and live clinical settings. Copyright © 2016 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  9. Wireless sensor and data transmission needs and technologies for patient monitoring in the operating room and intensive care unit.

    PubMed

    Paksuniemi, M; Sorvoja, H; Alasaarela, E; Myllyla, R

    2005-01-01

    In the intensive care unit, or during anesthesia, patients are attached to monitors by cables. These cables obstruct nursing staff and hinder the patients from moving freely in the hospital. However, rapidly developing wireless technologies are expected to solve these problems. To this end, this study revealed problem areas in current patient monitoring and established the most important medical parameters to monitor. In addition, usable wireless techniques for short-range data transmission were explored and currently employed wireless applications in the hospital environment were studied. The most important parameters measured of the patient include blood pressures, electrocardiography, respiration rate, heart rate and temperature. Currently used wireless techniques in hospitals are based on the WMTS and WLAN standards. There are no viable solutions for short-range data transmission from patient sensors to patient monitors, but potentially usable techniques in the future are based on the WPAN standards. These techniques include Bluetooth, ZigBee and UWB. Other suitable techniques might be based on capacitive or inductive coupling. The establishing of wireless techniques depends on ensuring the reliability of data transmission, eliminating disturbance by other wireless devices, ensuring patient data security and patient safety, and lowering the power consumption and price.

  10. The Breakthrough Listen Search for Intelligent Life: Radio Frequency Interference in the Green Bank Telescope

    NASA Astrophysics Data System (ADS)

    Dana, Ryan

    2018-01-01

    In the search for extra terrestrial intelligence, the vast majority of our “signals of interest,” are simply satellite radio frequency interference. The goal to my research, therefore, was to accurately predict the exact locations of satellites in our sky to analyze specific satellites causing the interference as well as potentially predict when satellites will cross in the way of our beams so that we can further optimize our scripts and get more usable data.I have built an algorithm that plots the exact location in altitude and azimuth of any grouping of satellites that you want in the sky from any position on earth in latitude, longitude, and elevation. From there, you can input a specific right ascension and declination of the location you are trying to track in the sky with a telescope. Using these inputs, we can calculate the angular and positional distance of certain satellites to our beam to further analyze satellite radio frequency interference.The process begins by importing a list of Two Line Element information that the algorithm reads in. Two Line Elements are how Satellites are organized and are updated frequently. They give a variety of information ranging from the Satellite ID to its Mean Motion or anomaly. From there, the code breaks up the information given by these elements to predict their location. The algorithm can also plot in 3D coordinates around an earthlike sphere to conceptualize the route that each Satellite has taken.The code has been used in a variety of ways but most notably to identify satellites interfering with the beam for Arecibo’s Ross 128 Candidate signal. From here, the code will be the backbone to calculating drift rates, Doppler shifts and intensity of certain satellites and why our team consistently receives estranged satellite signals of interest. Furthermore, in the case of a serious candidate signal in the near future, it will be important to analyze satellites interfering in the beam.

  11. Evaluating Usability in a Distance Digital Systems Laboratory Class

    ERIC Educational Resources Information Center

    Kostaras, N.; Xenos, M.; Skodras, A. N.

    2011-01-01

    This paper presents the usability evaluation of a digital systems laboratory class offered to distance-learning students. It details the way in which students can participate remotely in such a laboratory, the methodology employed in the usability assessment of the laboratory infrastructure (hardware and software), and also outlines the main…

  12. A Usability Evaluation of Academic Virtual Reference Services

    ERIC Educational Resources Information Center

    Chow, Anthony S.; Croxton, Rebecca A.

    2014-01-01

    This study examined the usability of five virtual reference services--instant messenger chat, e-mail, telephone, text messaging, and Skype videoconferencing--by having 31 undergraduate and graduate students evaluate the usability of the virtual reference services of two different universities. The study's results suggest that user preference and…

  13. An Online Social Constructivist Course: Toward a Framework for Usability Evaluations

    ERIC Educational Resources Information Center

    Phillips, Alana S.; Sheffield, Anneliese; Moore, Michelle; Robinson, Heather A.

    2016-01-01

    There is a need for a holistic usability evaluation framework that accommodates social constructivist online courses. Social knowledge construction may not be adequately evaluated using current frameworks. This qualitative research study examined the usability needs of a social constructivist online course. Data from an online course were analyzed…

  14. A Call for Bioimaging Software Usability

    PubMed Central

    Carpenter, Anne E.; Kamentsky, Lee; Eliceiri, Kevin W.

    2013-01-01

    Bioimaging software developed in a research setting often fails to be widely used by the scientific community. We suggest that, to maximize both the public’s and researchers’ investments, usability should be a more highly valued goal. We describe specific characteristics of usability towards which bioimaging software projects should aim. PMID:22743771

  15. Training Teachers and Serving Students: Applying Usability Testing in Writing Programs

    ERIC Educational Resources Information Center

    McGovern, Heather

    2007-01-01

    Teachers often test course materials by using them in class. Usability testing provides an alternative: teachers receive student feedback and revise materials "before" teaching a class. Case studies based on interviews and observations with two teaching assistants who usability tested materials before teaching introductory technical writing…

  16. Usability Assessment of E-Café Operational Management Simulation Game

    ERIC Educational Resources Information Center

    Chang, Chiung-sui; Huang, Ya-Ping

    2013-01-01

    To ensure the quality of digital simulation game, we utilized the usability evaluation heuristic in the design and development processes of e-café operational management game-based learning material for students. The application of usability evaluations during this study is described. Additionally, participant selection, data collection and…

  17. Users Views about the Usability of Digital Libraries

    ERIC Educational Resources Information Center

    Koohang, Alex; Ondracek, James

    2005-01-01

    This study examined users' views about the usability of digital libraries' current and perceived importance. Age, gender, prior experience with the Internet, college status, and digital library proficiency are the independent variables. Users' current views about the usability of digital libraries and users perceived importance of digital library…

  18. A systematic review of usability test metrics for mobile video streaming apps

    NASA Astrophysics Data System (ADS)

    Hussain, Azham; Mkpojiogu, Emmanuel O. C.

    2016-08-01

    This paper presents the results of a systematic review regarding the usability test metrics for mobile video streaming apps. In the study, 238 studies were found, but only 51 relevant papers were eventually selected for the review. The study reveals that time taken for video streaming and the video quality were the two most popular metrics used in the usability tests for mobile video streaming apps. Besides, most of the studies concentrated on the usability of mobile TV as users are switching from traditional TV to mobile TV.

  19. Task-specific usability requirements of electronic medical records systems: Lessons learned from a national survey of end-users.

    PubMed

    Farzandipour, Mehrdad; Meidani, Zahra; Riazi, Hossein; Sadeqi Jabali, Monireh

    2018-09-01

    There are various approaches to evaluating the usability of electronic medical record (EMR) systems. User perspectives are an integral part of evaluation. Usability evaluations efficiently and effectively contribute to user-centered design and supports tasks and increase user satisfaction. This study determined the main usability requirements for EMRs by means of an end-user survey. A mixed-method strategy was conducted in three phases. A qualitative approach was employed to collect and formulate EMR usability requirements using the focus group method and the modified Delphi technique. Classic Delphi technique was used to evaluate the proposed requirements among 380 end-users in Iran. The final list of EMR usability requirements was verified and included 163 requirements divided into nine groups. The highest rates of end-user agreement relate to EMR visual clarity (3.65 ± 0.61), fault tolerance (3.58 ± 0.56), and suitability for learning (3.55 ± 0.54). The lowest end-user agreement was for auditory presentation (3.18 ± 0.69). The highest and lowest agreement among end-users was for visual clarity and auditory presentation by EMRs, respectively. This suggests that user priorities in determination of EMR usability and their understanding of the importance of the types of individual tasks and context characteristics differ.

  20. A literature review about usability evaluation methods for e-learning platforms.

    PubMed

    Freire, Luciana Lopes; Arezes, Pedro Miguel; Campos, José Creissac

    2012-01-01

    The usability analysis of information systems has been the target of several research studies over the past thirty years. These studies have highlighted a great diversity of points of view, including researchers from different scientific areas such as Ergonomics, Computer Science, Design and Education. Within the domain of information ergonomics, the study of tools and methods used for usability evaluation dedicated to E-learning presents evidence that there is a continuous and dynamic evolution of E-learning systems, in many different contexts -academics and corporative. These systems, also known as LMS (Learning Management Systems), can be classified according to their educational goals and their technological features. However, in these systems the usability issues are related with the relationship/interactions between user and system in the user's context. This review is a synthesis of research project about Information Ergonomics and embraces three dimensions, namely the methods, models and frameworks that have been applied to evaluate LMS. The study also includes the main usability criteria and heuristics used. The obtained results show a notorious change in the paradigms of usability, with which it will be possible to discuss about the studies carried out by different researchers that were focused on usability ergonomic principles aimed at E-learning.

  1. Usability of online psychoeducation for siblings of people with psychosis.

    PubMed

    Sin, Jacqueline; Henderson, Claire; Norman, Ian

    2014-10-01

    The E Sibling Project aims to address the needs of siblings of individuals affected by psychosis through provision of a comprehensive online intervention. The online intervention comprises four core elements, including: information on psychosis; various coping and promoting well-being strategies; siblings' blogs and discussion forum with peers; and an "Ask the Experts" function. After the intervention-prototype was developed, we tested its feasibility, usability and acceptability by siblings. We evaluated the usability of the intervention-prototype using a non-randomised usability study with siblings of individuals diagnosed with psychosis. The usability study adapted Poulson et al's framework to collect subjective feedback from participants on ease of use, perceived usefulness and acceptability, together with objective usage data on the intervention. Twenty siblings were recruited to the usability test; 19 tried out the resource-prototype over a 4-week period and 17 completed the online evaluation after using the intervention. In total, 906 page-views were made by the participants and each spent about two hours using the resource. Participants evaluated the intervention as helpful, relevant and useful in terms of content, design and usability. Developments are needed to improve the navigation and intuitiveness of the resource. Using an internet-based information-giving and peer support intervention to promote wellbeing and coping is feasible and acceptable to siblings of people with psychosis.

  2. The STEP database through the end-users eyes--USABILITY STUDY.

    PubMed

    Salunke, Smita; Tuleu, Catherine

    2015-08-15

    The user-designed database of Safety and Toxicity of Excipients for Paediatrics ("STEP") is created to address the shared need of drug development community to access the relevant information of excipients effortlessly. Usability testing was performed to validate if the database satisfies the need of the end-users. Evaluation framework was developed to assess the usability. The participants performed scenario based tasks and provided feedback and post-session usability ratings. Failure Mode Effect Analysis (FMEA) was performed to prioritize the problems and improvements to the STEP database design and functionalities. The study revealed several design vulnerabilities. Tasks such as limiting the results, running complex queries, location of data and registering to access the database were challenging. The three critical attributes identified to have impact on the usability of the STEP database included (1) content and presentation (2) the navigation and search features (3) potential end-users. Evaluation framework proved to be an effective method for evaluating database effectiveness and user satisfaction. This study provides strong initial support for the usability of the STEP database. Recommendations would be incorporated into the refinement of the database to improve its usability and increase user participation towards the advancement of the database. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. How Do Clinical Information Systems Affect the Cognitive Demands of General Practitioners?: Usability Study with a Focus on Cognitive Workload.

    PubMed

    Ariza, Ferran; Kalra, Dipak; Potts, Henry Ww

    2015-11-20

    Clinical information systems in the National Health Service do not need to conform to any explicit usability requirements. Poor usability can increase the mental workload experienced by clinicians and cause fatigue, increase error rates and impact the overall patient safety. Mental workload can be used as a measure of usability. To assess the subjective cognitive workload experienced by general practitioners (GPs) with their systems. To raise awareness of the importance of usability in system design among users, designers, developers and policymakers. We used a modified version of the NASA Task Load Index, adapted for web. We developed a set of common clinical scenarios and computer tasks on an online survey. We emailed the study link to 199 clinical commissioning groups and 1,646 GP practices in England. Sixty-seven responders completed the survey. The respondents had spent an average of 17 years in general practice, had experience of using a mean of 1.5 GP computer systems and had used their current system for a mean time of 6.7 years. The mental workload score was not different among systems. There were significant differences among the task scores, but these differences were not specific to particular systems. The overall score and task scores were related to the length of experience with their present system. Four tasks imposed a higher mental workload on GPs: 'repeat prescribing', 'find episode', 'drug management' and 'overview records'. Further usability studies on GP systems should focus on these tasks. Users, policymakers, designers and developers should remain aware of the importance of usability in system design.What does this study add?• Current GP systems in England do not need to conform to explicit usability requirements. Poor usability can increase the mental workload of clinicians and lead to errors.• Some clinical computer tasks incur more cognitive workload than others and should be considered carefully during the design of a system.• GPs did not report overall very high levels of subjective cognitive workload when undertaking common clinical tasks with their systems.• Further usability studies on GP systems should focus on the tasks incurring higher cognitive workload.• Users, policymakers, and designers and developers should remain aware of the importance of usability in system design.

  4. "Thinking on your feet": A qualitative evaluation of sit-stand desks in an Australian workplace.

    PubMed

    Grunseit, Anne Carolyn; Chau, Josephine Yuk-Yin; van der Ploeg, Hidde Pieter; Bauman, Adrian

    2013-04-18

    Epidemiological research has established sitting as a new risk factor for the development of non-communicable chronic disease. Sit-stand desks have been proposed as one strategy to reduce occupational sedentary time. This formative research study evaluated the acceptability and usability of manually and electrically operated sit-stand desks in a medium-sized government organisation located in Sydney, Australia. Sitting time pre- and three months post -installation of the sit-stand desks was measured using validated self-report measures. Additionally, three group interviews and one key-informant interview were conducted with staff regarding perceptions about ease of, and barriers to, use and satisfaction with the sit-stand desks. All interviews were recorded, transcribed and analysed for themes regarding usability and acceptability. Of 31 staff, 18 completed baseline questionnaires, and 13 completed follow-up questionnaires. The median proportion of sitting time for work was 85% (range 50%-95%) at baseline and 60% (range 10%-95%) at follow-up. Formal statistical testing of paired data (n=11) showed that the change from baseline to follow-up in time spent sitting (mean change=1.7 hours, p=.014) was statistically significant. From the qualitative data, reasons given for initiating use of the desks in the standing position were the potential health benefits, or a willingness to experiment or through external prompting. Factors influencing continued use included: concern for, and experience of, short and long term health impacts; perceived productivity whilst sitting and standing; practical accommodation of transitions between sitting and standing; electric or manual operation height adjustment. Several trajectories in patterns of initiation and continued use were identified that centered on the source and timing of commitment to using the desk in the standing position. Sit-stand desks had high usability and acceptability and reduced sitting time at work. Use could be promoted by emphasizing the health benefits, providing guidance on appropriate set-up and normalizing standing for work-related tasks.

  5. “Thinking on your feet”: A qualitative evaluation of sit-stand desks in an Australian workplace

    PubMed Central

    2013-01-01

    Background Epidemiological research has established sitting as a new risk factor for the development of non-communicable chronic disease. Sit-stand desks have been proposed as one strategy to reduce occupational sedentary time. This formative research study evaluated the acceptability and usability of manually and electrically operated sit-stand desks in a medium-sized government organisation located in Sydney, Australia. Methods Sitting time pre- and three months post -installation of the sit-stand desks was measured using validated self-report measures. Additionally, three group interviews and one key-informant interview were conducted with staff regarding perceptions about ease of, and barriers to, use and satisfaction with the sit-stand desks. All interviews were recorded, transcribed and analysed for themes regarding usability and acceptability. Results Of 31 staff, 18 completed baseline questionnaires, and 13 completed follow-up questionnaires. The median proportion of sitting time for work was 85% (range 50%-95%) at baseline and 60% (range 10%-95%) at follow-up. Formal statistical testing of paired data (n=11) showed that the change from baseline to follow-up in time spent sitting (mean change=1.7 hours, p=.014) was statistically significant. From the qualitative data, reasons given for initiating use of the desks in the standing position were the potential health benefits, or a willingness to experiment or through external prompting. Factors influencing continued use included: concern for, and experience of, short and long term health impacts; perceived productivity whilst sitting and standing; practical accommodation of transitions between sitting and standing; electric or manual operation height adjustment. Several trajectories in patterns of initiation and continued use were identified that centered on the source and timing of commitment to using the desk in the standing position. Conclusions Sit-stand desks had high usability and acceptability and reduced sitting time at work. Use could be promoted by emphasizing the health benefits, providing guidance on appropriate set-up and normalizing standing for work-related tasks. PMID:23597291

  6. Cluster analysis based on dimensional information with applications to feature selection and classification

    NASA Technical Reports Server (NTRS)

    Eigen, D. J.; Fromm, F. R.; Northouse, R. A.

    1974-01-01

    A new clustering algorithm is presented that is based on dimensional information. The algorithm includes an inherent feature selection criterion, which is discussed. Further, a heuristic method for choosing the proper number of intervals for a frequency distribution histogram, a feature necessary for the algorithm, is presented. The algorithm, although usable as a stand-alone clustering technique, is then utilized as a global approximator. Local clustering techniques and configuration of a global-local scheme are discussed, and finally the complete global-local and feature selector configuration is shown in application to a real-time adaptive classification scheme for the analysis of remote sensed multispectral scanner data.

  7. Automatic interpretation of oblique ionograms

    NASA Astrophysics Data System (ADS)

    Ippolito, Alessandro; Scotto, Carlo; Francis, Matthew; Settimi, Alessandro; Cesaroni, Claudio

    2015-03-01

    We present an algorithm for the identification of trace characteristics of oblique ionograms allowing determination of the Maximum Usable Frequency (MUF) for communication between the transmitter and receiver. The algorithm automatically detects and rejects poor quality ionograms. We performed an exploratory test of the algorithm using data from a campaign of oblique soundings between Rome, Italy (41.90 N, 12.48 E) and Chania, Greece (35.51 N, 24.01 E) and also between Kalkarindji, Australia (17.43 S, 130.81 E) and Culgoora, Australia (30.30 S, 149.55 E). The success of these tests demonstrates the applicability of the method to ionograms recorded by different ionosondes in various helio and geophysical conditions.

  8. Evaluating Usability of Radiology Information Systems in Hospitals of Tabriz University of Medical Sciences.

    PubMed

    Rezaei-Hachesu, Peyman; Pesianian, Esmaeil; Mohammadian, Mohsen

    2016-02-01

    Radiology information system (RIS) in order to reduce workload and improve the quality of services must be well-designed. Heuristic evaluation is one of the methods that understand usability problems with the least time, cost and resources. The aim of present study is to evaluate the usability of RISs in hospitals. This is a cross-sectional descriptive study (2015) that uses heuristic evaluation method to evaluate the usability of RIS used in 3 hospitals of Tabriz city. The data are collected using a standard checklist based on 13 principles of Nielsen Heuristic evaluation method. Usability of RISs was investigated based on the number of components observed from Nielsen principles and problems of usability based on the number of non-observed components as well as non-existent or unrecognizable components. by evaluation of RISs in each of the hospitals 1, 2 and 3, total numbers of observed components were obtained as 173, 202 and 196, respectively. It was concluded that the usability of RISs in the studied population, on average and with observing 190 components of the 291 components related to the 13 principles of Nielsen is 65.41 %. Furthermore, problems of usability were obtained as 26.35%. The established and visible nature of some components such as response time of application, visual feedbacks, colors, view and design and arrangement of software objects cause more attention to these components as principal components in designing UI software. Also, incorrect analysis before system design leads to a lack of attention to secondary needs like Help software and security issues.

  9. Applying heuristic evaluation to improve the usability of a telemedicine system.

    PubMed

    Tang, Zhihua; Johnson, Todd R; Tindall, R Douglas; Zhang, Jiajie

    2006-02-01

    The development of a telemedicine system should not only take advantage of technological advances but also pay close attention to users and the human issues involved. In this paper we examine the utility of heuristic evaluation in improving the usability of a digital emergency medical services (EMS) system equipped on an ambulance. The digital EMS system used advanced communication technologies to help remotely located trauma specialists gain access to patient data in real-time and direct life-saving measures in a timely fashion. To improve its usability, three experts inspected prototypes of the system according to 14 software usability heuristics. The analyses revealed information on the prevalence, severity, and nature of heuristic violations in the user interface design. The results were subsequently utilized to guide the iterative software design process. A comparison between two consecutive prototypes showed that the second design had only half as many usability violations as the first prototype and had considerable improvement in a number of usability heuristic categories. The validity of heuristic evaluation was examined in an ethnographic study of paramedics using a prototype of the system in their work environment. Users' task performances partially verified heuristic evaluation results. However, they also revealed problems that were not identified in heuristic evaluation but only became prominent during field observation. In conclusion, we argue that usability should be given high priority in the development of a telemedicine system, and that heuristic evaluation can be an effective and efficient way to identify usability problems in the early stage of software development.

  10. Quality of information available on the World Wide Web for patients undergoing thyroidectomy: review.

    PubMed

    Muthukumarasamy, S; Osmani, Z; Sharpe, A; England, R J A

    2012-02-01

    This study aimed to assess the quality of information available on the World Wide Web for patients undergoing thyroidectomy. The first 50 web-links generated by internet searches using the five most popular search engines and the key word 'thyroidectomy' were evaluated using the Lida website validation instrument (assessing accessibility, usability and reliability) and the Flesch Reading Ease Score. We evaluated 103 of a possible 250 websites. Mean scores (ranges) were: Lida accessibility, 48/63 (27-59); Lida usability, 36/54 (21-50); Lida reliability, 21/51 (4-38); and Flesch Reading Ease, 43.9 (2.6-77.6). The quality of internet health information regarding thyroidectomy is variable. High ranking and popularity are not good indicators of website quality. Overall, none of the websites assessed achieved high Lida scores. In order to prevent the dissemination of inaccurate or commercially motivated information, we recommend independent labelling of medical information available on the World Wide Web.

  11. Usability evaluation of pharmacogenomics clinical decision support aids and clinical knowledge resources in a computerized provider order entry system: a mixed methods approach.

    PubMed

    Devine, Emily Beth; Lee, Chia-Ju; Overby, Casey L; Abernethy, Neil; McCune, Jeannine; Smith, Joe W; Tarczy-Hornoch, Peter

    2014-07-01

    Pharmacogenomics (PGx) is positioned to have a widespread impact on the practice of medicine, yet physician acceptance is low. The presentation of context-specific PGx information, in the form of clinical decision support (CDS) alerts embedded in a computerized provider order entry (CPOE) system, can aid uptake. Usability evaluations can inform optimal design, which, in turn, can spur adoption. The study objectives were to: (1) evaluate an early prototype, commercial CPOE system with PGx-CDS alerts in a simulated environment, (2) identify potential improvements to the system user interface, and (3) understand the contexts under which PGx knowledge embedded in an electronic health record is useful to prescribers. Using a mixed methods approach, we presented seven cardiologists and three oncologists with five hypothetical clinical case scenarios. Each scenario featured a drug for which a gene encoding drug metabolizing enzyme required consideration of dosage adjustment. We used Morae(®) to capture comments and on-screen movements as participants prescribed each drug. In addition to PGx-CDS alerts, 'Infobutton(®)' and 'Evidence' icons provided participants with clinical knowledge resources to aid decision-making. Nine themes emerged. Five suggested minor improvements to the CPOE user interface; two suggested presenting PGx information through PGx-CDS alerts using an 'Infobutton' or 'Evidence' icon. The remaining themes were strong recommendations to provide succinct, relevant guidelines and dosing recommendations of phenotypic information from credible and trustworthy sources; any more information was overwhelming. Participants' median rating of PGx-CDS system usability was 2 on a Likert scale ranging from 1 (strongly agree) to 7 (strongly disagree). Usability evaluation results suggest that participants considered PGx information important for improving prescribing decisions; and that they would incorporate PGx-CDS when information is presented in relevant and useful ways. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  12. New Options for Usability Testing Projects in Business Communication Courses

    ERIC Educational Resources Information Center

    Jameson, Daphne A.

    2013-01-01

    The increasing availability of recording technologies makes it easier to include usability testing projects in business communication courses. Usability testing is a method of discovering whether people can navigate, read, and understand a print or electronic communication well enough to achieve a particular purpose in a reasonable time frame.…

  13. Collecting and Applying Usability Data from Distance Learners

    ERIC Educational Resources Information Center

    Mitchell, Emily; West, Brandon

    2017-01-01

    Growth of their college's off-campus and online course offerings led librarians at SUNY Oswego to run usability tests with off-campus students to compensate for a lack of responses from this population during earlier usability testing. Constraints on testing with off-campus students included lack of funding and librarian time, as well as…

  14. Evaluation of Usability Utilizing Markov Models

    ERIC Educational Resources Information Center

    Penedo, Janaina Rodrigues; Diniz, Morganna; Ferreira, Simone Bacellar Leal; Silveira, Denis S.; Capra, Eliane

    2012-01-01

    Purpose: The purpose of this paper is to analyze the usability of a remote learning system in its initial development phase, using a quantitative usability evaluation method through Markov models. Design/methodology/approach: The paper opted for an exploratory study. The data of interest of the research correspond to the possible accesses of users…

  15. Adding Users to the Website Design Process

    ERIC Educational Resources Information Center

    Tomeo, Megan L.

    2012-01-01

    Alden Library began redesigning its website over a year ago. Throughout the redesign process the students, faculty, and staff that make up the user base were added to the conversation by utilizing several usability test methods. This article focuses on the usability testing conducted at Alden Library and delves into future usability testing, which…

  16. Effect of Improving the Usability of an E-Learning Resource: A Randomized Trial

    ERIC Educational Resources Information Center

    Davids, Mogamat Razeen; Chikte, Usuf M. E.; Halperin, Mitchell L.

    2014-01-01

    Optimizing the usability of e-learning materials is necessary to reduce extraneous cognitive load and maximize their potential educational impact. However, this is often neglected, especially when time and other resources are limited. We conducted a randomized trial to investigate whether a usability evaluation of our multimedia e-learning…

  17. The Virtual Anatomy Laboratory: Usability Testing to Improve an Online Learning Resource for Anatomy Education

    ERIC Educational Resources Information Center

    Doubleday, Eldridge G.; O'Loughlin, Valerie D.; Doubleday, Alison F.

    2011-01-01

    An increasing number of instructors are seeking to provide students with online anatomy resources. Many researchers have attempted to identify associations between resource use and student learning but few studies discuss the importance of usability testing in resource design and modification. Usability testing provides information about ease of…

  18. Training Software Developers and Designers to Conduct Usability Evaluations

    ERIC Educational Resources Information Center

    Skov, Mikael Brasholt; Stage, Jan

    2012-01-01

    Many efforts to improve the interplay between usability evaluation and software development rely either on better methods for conducting usability evaluations or on better formats for presenting evaluation results in ways that are useful for software designers and developers. Both of these approaches depend on a complete division of work between…

  19. The Relationship between National Culture and the Usability of an E-Learning System

    ERIC Educational Resources Information Center

    Downey, Steve; Wentling, Rose Mary; Wentling, Tim; Wadsworth, Andrew

    2004-01-01

    This study sought to measure the relationship between national culture and the usability of an e-Learning system by using Hofstede's cultural dimensions and Nielson's usability attributes. The study revealed that high uncertainty avoidance cultures found the system more frustrating to use. The study also revealed that individuals from cultures…

  20. Grappling with Distributed Usability: A Cultural-Historical Examination of Documentation Genres Over Four Decades.

    ERIC Educational Resources Information Center

    Spinuzzi, Clay

    2001-01-01

    Describes and illustrates a distributed approach to usability (envisioning usability across the genres, practices, uses, and goals of a given activity) using a four-decade examination of a traffic accident location and analysis system. Uses the theoretical framework of "genre ecologies" to show how communities of users interact with…

  1. Design and Usability of Digital Libraries: Case Studies in the Asia Pacific

    ERIC Educational Resources Information Center

    Theng, Yin-Leng, Ed.; Foo, Schubert, Ed.

    2005-01-01

    This book showcases some of the best digital library practices from organizations in the Asia Pacific. Particular emphasis has been placed on the design, use and usability of digital libraries. Not only are digital libraries examined, but related technologies, the management of knowledge in digital libraries, and the associated usability and…

  2. Usability Studies and User-Centered Design in Digital Libraries

    ERIC Educational Resources Information Center

    Comeaux, David J.

    2008-01-01

    Digital libraries continue to flourish. At the same time, the principles of user-centered design and the practice of usability testing have been growing in popularity, spreading their influence into the library sphere. This article explores the confluence of these two trends by surveying the current literature on usability studies of digital…

  3. Earning the Stamp of Approval: How To Achieve Optimal Usability.

    ERIC Educational Resources Information Center

    Makar, Susan

    2003-01-01

    Describes the redesign of the Web site at the virtual library of the NIST (National Institute of Standards and Technology). Discusses usability problems with the original site, including navigation difficulties; focus groups to determine user needs; usability testing for the new Web site; and the importance of customer input. (LRW)

  4. Using Eye Trackers for Usability Evaluation of Health Information Technology: A Systematic Literature Review

    PubMed Central

    Yang, Yushi

    2015-01-01

    Background Eye-tracking technology has been used to measure human cognitive processes and has the potential to improve the usability of health information technology (HIT). However, it is still unclear how the eye-tracking method can be integrated with other traditional usability methodologies to achieve its full potential. Objective The objective of this study was to report on HIT evaluation studies that have used eye-tracker technology, and to envision the potential use of eye-tracking technology in future research. Methods We used four reference databases to initially identify 5248 related papers, which resulted in only 9 articles that met our inclusion criteria. Results Eye-tracking technology was useful in finding usability problems in many ways, but is still in its infancy for HIT usability evaluation. Limited types of HITs have been evaluated by eye trackers, and there has been a lack of evaluation research in natural settings. Conclusions More research should be done in natural settings to discover the real contextual-based usability problems of clinical and mobile HITs using eye-tracking technology with more standardized methodologies and guidance. PMID:27026079

  5. Internationalization and localization: evaluating and testing a Website for Asian users.

    PubMed

    Rau, Pei-Luen Patrick; Liang, Sheau-Farn Max

    2003-01-15

    The objective of this study was to combine internationalization and localization of Websites and improvement of Website usability with user-centred design methods. This study designed for internationalization and localization of Websites for Asian users, and implemented usability engineering into every phase of Website usability testing, based on the internationalization and localization perspectives of the honeywell.com/your home Website. The first step was to develop the usage scenarios. Three Asian usability specialists carried out one heuristic evaluation session for the current honeywell.com/your home Website. The usability problems were analysed and possible solutions to these problems were discussed. In the next phase, cluster analysis was utilized to test current information architecture. The results provided options for future information architecture development for this Website. Finally, a performance measurement test was conducted to investigate the performance for Asian users. Based on the results, suggestions for improving the Website usability from the localization perspective were provided. The results demonstrate the user-centred design (UCD) approach and stress international and local issues in Website development to Website designers.

  6. The Cultural Evolution of Human Communication Systems in Different Sized Populations: Usability Trumps Learnability

    PubMed Central

    Fay, Nicolas; Ellison, T. Mark

    2013-01-01

    This study examines the intergenerational transfer of human communication systems. It tests if human communication systems evolve to be easy to learn or easy to use (or both), and how population size affects learnability and usability. Using an experimental-semiotic task, we find that human communication systems evolve to be easier to use (production efficiency and reproduction fidelity), but harder to learn (identification accuracy) for a second generation of naïve participants. Thus, usability trumps learnability. In addition, the communication systems that evolve in larger populations exhibit distinct advantages over those that evolve in smaller populations: the learnability loss (from the Initial signs) is more muted and the usability benefits are more pronounced. The usability benefits for human communication systems that evolve in a small and large population is explained through guided variation reducing sign complexity. The enhanced performance of the communication systems that evolve in larger populations is explained by the operation of a content bias acting on the larger pool of competing signs. The content bias selects for information-efficient iconic signs that aid learnability and enhance usability. PMID:23967243

  7. Connection between competence, usability, environment and risk of falls in elderly adults.

    PubMed

    Leiva-Caro, José Alex; Salazar-González, Bertha Cecilia; Gallegos-Cabriales, Esther Carlota; Gómez-Meza, Marco Vinicio; Hunter, Kathleen F

    2015-01-01

    To determine connections between competence, usability, environment and risk of falls in elderly adults. Correlational descriptive study, 123 elderly adults, both male and female, aged 70 years and older were included. Data was collected via the Tinetti Scale, CESD-7 Scale, Montreal Cognitive Assessment, Usability Questionnaire on Housing and Housing Enabler; and sociodemographic and health background certificate data. For data analysis, descriptive and inferential statistics were used, multivariate linear and logistic regression models were adjusted. 42.0% of the elderly adults had presented with falls, with a higher prevalence in women, and in the group of 70-75 years. The physical environment of the house, gait, and usability were set as risk factors for falls. A negative relationship between usability and depressive symptoms, cognitive health, balance, gait, the social and physical environment was found, p <0.05; and a strong positive correlation between walking and balance, p <0.05. This study helps to better understand the phenomenon of falling, to find a connection between usability with the risk of falls, and other variables.

  8. Connection between competence, usability, environment and risk of falls in elderly adults

    PubMed Central

    Leiva-Caro, José Alex; Salazar-González, Bertha Cecilia; Gallegos-Cabriales, Esther Carlota; Gómez-Meza, Marco Vinicio; Hunter, Kathleen F.

    2015-01-01

    Objective: to determine connections between competence, usability, environment and risk of falls in elderly adults. Method: correlational descriptive study, 123 elderly adults, both male and female, aged 70 years and older were included. Data was collected via the Tinetti Scale, CESD-7 Scale, Montreal Cognitive Assessment, Usability Questionnaire on Housing and Housing Enabler; and sociodemographic and health background certificate data. For data analysis, descriptive and inferential statistics were used, multivariate linear and logistic regression models were adjusted. Results: 42.0% of the elderly adults had presented with falls, with a higher prevalence in women, and in the group of 70-75 years. The physical environment of the house, gait, and usability were set as risk factors for falls. A negative relationship between usability and depressive symptoms, cognitive health, balance, gait, the social and physical environment was found, p <0.05; and a strong positive correlation between walking and balance, p <0.05. Conclusion: this study helps to better understand the phenomenon of falling, to find a connection between usability with the risk of falls, and other variables. PMID:26626006

  9. The cultural evolution of human communication systems in different sized populations: usability trumps learnability.

    PubMed

    Fay, Nicolas; Ellison, T Mark

    2013-01-01

    This study examines the intergenerational transfer of human communication systems. It tests if human communication systems evolve to be easy to learn or easy to use (or both), and how population size affects learnability and usability. Using an experimental-semiotic task, we find that human communication systems evolve to be easier to use (production efficiency and reproduction fidelity), but harder to learn (identification accuracy) for a second generation of naïve participants. Thus, usability trumps learnability. In addition, the communication systems that evolve in larger populations exhibit distinct advantages over those that evolve in smaller populations: the learnability loss (from the Initial signs) is more muted and the usability benefits are more pronounced. The usability benefits for human communication systems that evolve in a small and large population is explained through guided variation reducing sign complexity. The enhanced performance of the communication systems that evolve in larger populations is explained by the operation of a content bias acting on the larger pool of competing signs. The content bias selects for information-efficient iconic signs that aid learnability and enhance usability.

  10. The Imperative of Solving Nurses' Usability Problems With Health Information Technology.

    PubMed

    Staggers, Nancy; Elias, Beth L; Makar, Ellen; Alexander, Gregory L

    2018-04-01

    Health information technology (IT) usability issues are a key concern for nurse executives and nurses. The aims of this study are to understand usability pain points faced by nurses regarding the use of health IT, identify their impact and importance, discuss responsibilities, and develop possible solutions to improve the health IT-user experience for nurses. Twenty-seven experts were interviewed including nursing leaders, informaticists, executives, engineers, researchers, and human factors experts across acute care, long-term care, and vendor settings. Semistructured questions guided the interviews, and content analysis was used to identify themes. Four themes emerged: 1) user experience pain points, 2) importance of the issues, 3) the responsibility gap, and 4) acting on usability issues. Nurses continue to endure significant health IT-usability issues that negatively impact patients, nurses, and healthcare organizations. Solutions include enhancing the voice of nursing at the national and local levels, creating a digital strategy for nursing, providing incentives to improve usability in health IT, and accelerating the understanding of nurses' work intended to inform and translate nurses' work into health IT design.

  11. The influence of socio-cultural background and product value in usability testing.

    PubMed

    Sonderegger, Andreas; Sauer, Juergen

    2013-05-01

    This article examines the influence of socio-cultural background and product value on different outcomes of usability tests. A study was conducted in two different socio-cultural regions, Switzerland and East Germany, which differed in a number of aspects (e.g. economic power, price sensitivity and culture). Product value (high vs. low) was varied by manipulating the price of the product. Sixty-four test participants were asked to carry out five typical user tasks in the context of coffee machine usage, measuring performance, perceived usability, and emotion. The results showed that in Switzerland, high-value products were rated higher in usability than low-value products whereas in East Germany, high-value products were evaluated lower in usability. A similar interaction effect of socio-cultural background and product value was observed for user emotion. Implications are that the outcomes of usability tests do not allow for a simple transfer across cultures and that the mediating influence of perceived product value needs to be taken into consideration. Copyright © 2012 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  12. Evaluating input device usability as a function of task difficulty in a tracking task.

    PubMed

    Rupp, Michael A; Oppold, Paul; McConnell, Daniel S

    2015-01-01

    Game controllers are emerging as a preferred choice for the manual control of unmanned vehicles, but an understanding of their usability characteristics has yet to emerge. We compared the usability of an Xbox 360 game controller in a dual task situation using MATB II to the traditional joystick and keyboard interface in two experiments. In the first experiment, performance with the game controller was associated with fewer tracking errors. In a second experiment, we trained users on the devices, and found that even after training the game controller was still associated with fewer tracking errors as well as higher usability and lower workload ratings. These results are consistent with the idea that game controllers are highly usable input devices and do not require high mental workload to operate, thus making them suitable for complex control tasks.

  13. Biofeedback in Partial Weight Bearing: Usability of Two Different Devices from a Patient's and Physical Therapist's Perspective.

    PubMed

    van Lieshout, Remko; Pisters, Martijn F; Vanwanseele, Benedicte; de Bie, Rob A; Wouters, Eveline J; Stukstette, Mirelle J

    2016-01-01

    Partial weight bearing is frequently instructed by physical therapists in patients after lower-limb trauma or surgery. The use of biofeedback devices seems promising to improve the patient's compliance with weight-bearing instructions. SmartStep and OpenGo-Science are biofeedback devices that provide real-time feedback. For a successful implementation, usability of the devices is a critical aspect and should be tested from a user's perspective. To describe the usability from the physical therapists' and a patients' perspective of Smartstep and OpenGo-Science to provide feedback on partial weight bearing during supervised rehabilitation of patients after lower-limb trauma or surgery. In a convergent mixed-methods design, qualitative and quantitative data were collected. Usability was subdivided into user performance, satisfaction and acceptability. Patients prescribed with partial weight bearing and their physical therapists were asked to use SmartStep and OpenGo-Science during supervised rehabilitation. Usability was qualitatively tested by a think-aloud method and a semi-structured interview and quantitatively tested by the System-Usability-Scale (SUS) and closed questions. For the qualitative data thematic content analyses were used. Nine pairs of physical therapists and their patients participated. The mean SUS scores for patients and physical therapists were for SmartStep 70 and 53, and for OpenGo-Science 79 and 81, respectively. Scores were interpreted with the Curved Grading Scale. The qualitative data showed that there were mixed views and perceptions from patients and physical therapists on satisfaction and acceptability. This study gives insight in the usability of two biofeedback devices from the patient's and physical therapist's perspective. The overall usability from both perspectives seemed to be acceptable for OpenGo-Science. For SmartStep, overall usability seemed only acceptable from the patient's perspective. The study findings could help clinicians to decide which biofeedback device is appropriate for their given situation and provide information for future development of biofeedback devices.

  14. Engaging Community Stakeholders to Evaluate the Design, Usability, and Acceptability of a Chronic Obstructive Pulmonary Disease Social Media Resource Center

    PubMed Central

    Chaney, Beth; Chaney, Don; Paige, Samantha; Payne-Purvis, Caroline; Tennant, Bethany; Walsh-Childers, Kim; Sriram, PS; Alber, Julia

    2015-01-01

    Background Patients with chronic obstructive pulmonary disease (COPD) often report inadequate access to comprehensive patient education resources. Objective The purpose of this study was to incorporate community-engagement principles within a mixed-method research design to evaluate the usability and acceptability of a self-tailored social media resource center for medically underserved patients with COPD. Methods A multiphase sequential design (qual → QUANT → quant + QUAL) was incorporated into the current study, whereby a small-scale qualitative (qual) study informed the design of a social media website prototype that was tested with patients during a computer-based usability study (QUANT). To identify usability violations and determine whether or not patients found the website prototype acceptable for use, each patient was asked to complete an 18-item website usability and acceptability questionnaire, as well as a retrospective, in-depth, semistructured interview (quant + QUAL). Results The majority of medically underserved patients with COPD (n=8, mean 56 years, SD 7) found the social media website prototype to be easy to navigate and relevant to their self-management information needs. Mean responses on the 18-item website usability and acceptability questionnaire were very high on a scale of 1 (strongly disagree) to 5 (strongly agree) (mean 4.72, SD 0.33). However, the majority of patients identified several usability violations related to the prototype’s information design, interactive capabilities, and navigational structure. Specifically, 6 out of 8 (75%) patients struggled to create a log-in account to access the prototype, and 7 out of 8 patients (88%) experienced difficulty posting and replying to comments on an interactive discussion forum. Conclusions Patient perceptions of most social media website prototype features (eg, clickable picture-based screenshots of videos, comment tools) were largely positive. Mixed-method stakeholder feedback was used to make design recommendations, categorize usability violations, and prioritize potential solutions for improving the usability of a social media resource center for COPD patient education. PMID:25630449

  15. SU-F-T-249: Application of Human Factors Methods: Usability Testing in the Radiation Oncology Environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Warkentin, H; Bubric, K; Giovannetti, H

    2016-06-15

    Purpose: As a quality improvement measure, we undertook this work to incorporate usability testing into the implementation procedures for new electronic documents and forms used by four affiliated radiation therapy centers. Methods: A human factors specialist provided training in usability testing for a team of medical physicists, radiation therapists, and radiation oncologists from four radiotherapy centers. A usability testing plan was then developed that included controlled scenarios and standardized forms for qualitative and quantitative feedback from participants, including patients. Usability tests were performed by end users using the same hardware and viewing conditions that are found in the clinical environment.more » A pilot test of a form used during radiotherapy CT simulation was performed in a single department; feedback informed adaptive improvements to the electronic form, hardware requirements, resource accessibility and the usability testing plan. Following refinements to the testing plan, usability testing was performed at three affiliated cancer centers with different vault layouts and hardware. Results: Feedback from the testing resulted in the detection of 6 critical errors (omissions and inability to complete task without assistance), 6 non-critical errors (recoverable), and multiple suggestions for improvement. Usability problems with room layout were detected at one center and problems with hardware were detected at one center. Upon amalgamation and summary of the results, three key recommendations were presented to the document’s authors for incorporation into the electronic form. Documented inefficiencies and patient safety concerns related to the room layout and hardware were presented to administration along with a request for funding to purchase upgraded hardware and accessories to allow a more efficient workflow within the simulator vault. Conclusion: By including usability testing as part of the process when introducing any new document or procedure into clinical use, associated risks can be identified and mitigated before patient care and clinical workflow are impacted.« less

  16. A Frequency Domain Approach to Pretest Analysis Model Correlation and Model Updating for the Mid-Frequency Range

    DTIC Science & Technology

    2009-02-01

    range of modal analysis and the high frequency region of statistical energy analysis , is referred to as the mid-frequency range. The corresponding...frequency range of modal analysis and the high frequency region of statistical energy analysis , is referred to as the mid-frequency range. The...predictions. The averaging process is consistent with the averaging done in statistical energy analysis for stochastic systems. The FEM will always

  17. Characterization of depolarizing fringing fields of a liquid crystal spatial light modulator for laser beam steering

    NASA Astrophysics Data System (ADS)

    Haellstig, Emil J.; Martin, Torleif; Stigwall, Johan; Sjoqvist, Lars; Lindgren, Mikael

    2004-02-01

    A commercial linear one-dimensional, 1x4096 pixels, zero-twist nematic liquid crystal spatial light modulator (SLM), giving more than 2π phase modulation at λ = 850 nm, was evaluated for beam steering applications. The large ratio (7:1) between the liquid crystal layer thickness and pixel width gives rise to voltage leakage and fringing fields between pixels. Due to the fringing fields the ideal calculated phase patterns cannot be perfectly realized by the device. Losses in high frequency components in the phase patterns were found to limit the maximum deflection angle. The inhomogeneous optical anisotropy of the SLM was determined by modelling of the liquid crystal director distribution within the electrode-pixel structure. The effects of the fringing fields on the amplitude and phase modulation were studied by full vector finite-difference time-domain simulations. It was found that the fringing fields also resulted in coupling into an unwanted polarization mode. Measurements of how this mode coupling affects the beam steering quality were carried out and the results compared with calculated results. A method to compensate for the fringing field effects is discussed and it is shown how the usable steering range of the SLM can be extended to +/- 2 degrees.

  18. Objective analysis of ambisonics for hearing aid applications: Effect of listener's head, room reverberation, and directional microphones.

    PubMed

    Oreinos, Chris; Buchholz, Jörg M

    2015-06-01

    Recently, an increased interest has been demonstrated in evaluating hearing aids (HAs) inside controlled, but at the same time, realistic sound environments. A promising candidate that employs loudspeakers for realizing such sound environments is the listener-centered method of higher-order ambisonics (HOA). Although the accuracy of HOA has been widely studied, it remains unclear to what extent the results can be generalized when (1) a listener wearing HAs that may feature multi-microphone directional algorithms is considered inside the reconstructed sound field and (2) reverberant scenes are recorded and reconstructed. For the purpose of objectively validating HOA for listening tests involving HAs, a framework was developed to simulate the entire path of sounds presented in a modeled room, recorded by a HOA microphone array, decoded to a loudspeaker array, and finally received at the ears and HA microphones of a dummy listener fitted with HAs. Reproduction errors at the ear signals and at the output of a cardioid HA microphone were analyzed for different anechoic and reverberant scenes. It was found that the diffuse reverberation reduces the considered time-averaged HOA reconstruction errors which, depending on the considered application, suggests that reverberation can increase the usable frequency range of a HOA system.

  19. Determining Usability Versus Cost and Yields of a Regional Transport

    NASA Technical Reports Server (NTRS)

    Gvozdenovic, Slobodan

    1999-01-01

    Regional transports are designed to operate on air networks having the basic characteristics of short trip distances and low density passengers/cargo, i.e. small numbers of passengers per flight. Regional transports passenger capacity is from 10 to 100 seats and operate on routes from 350 to 1000 nautical miles (nm). An air network operated by regional transports has the following characteristics: (1) connecting regional centers; (2) operating on low density passengers/cargo flow services with minimum two frequencies per day; (3) operating on high density passengers/cargo flow with more than two frequencies per day; and (4) operating supplemental services whenever market demands in order to help bigger capacity aircraft already operating the same routes. In order to meet passenger requirements providing low fares and high or required number of frequencies, airlines must constantly monitor operational costs and keep them low. It is obvious that costs of operating aircraft must be lower than yield obtained by transporting passengers and cargo. The requirement to achieve favorable yield/cost ratio must provide the answer to the question of which aircraft will best meet a specific air network. An air network is defined by the number of services, the trip distance of each service, and the number of flights (frequencies) per day and week.

  20. Development, Construction, and Content Validation of a Questionnaire to Test Mobile Shower Commode Usability

    PubMed Central

    Theodoros, Deborah G.; Russell, Trevor G.

    2015-01-01

    Background: Usability is an emerging domain of outcomes measurement in assistive technology provision. Currently, no questionnaires exist to test the usability of mobile shower commodes (MSCs) used by adults with spinal cord injury (SCI). Objective: To describe the development, construction, and initial content validation of an electronic questionnaire to test mobile shower commode usability for this population. Methods: The questionnaire was constructed using a mixed-methods approach in 5 phases: determining user preferences for the questionnaire’s format, developing an item bank of usability indicators from the literature and judgement of experts, constructing a preliminary questionnaire, assessing content validity with a panel of experts, and constructing the final questionnaire. Results: The electronic Mobile Shower Commode Assessment Tool Version 1.0 (eMAST 1.0) questionnaire tests MSC features and performance during activities identified using a mixed-methods approach and in consultation with users. It confirms that usability is complex and multidimensional. The final questionnaire contains 25 questions in 3 sections. The eMAST 1.0 demonstrates excellent content validity as determined by a small sample of expert clinicians. Conclusion: The eMAST 1.0 tests usability of MSCs from the perspective of adults with SCI and may be used to solicit feedback during MSC design, assessment, prescription, and ongoing use. Further studies assessing the eMAST’s psychometric properties, including studies with users of MSCs, are needed. PMID:25762862

  1. Pre-post evaluation of physicians' satisfaction with a redesigned electronic medical record system.

    PubMed

    Jaspers, Monique W M; Peute, Linda W P; Lauteslager, Arnaud; Bakker, Piet J M

    2008-01-01

    Physicians' acceptance of Electronic Medical Record Systems (EMRs) is closely related to their usability. Knowledge about end-users' opinions on usability of an EMR system may contribute to planning for the next phase of the usability cycle of the system. A demand for integration of new functionalities, such as computerized order entry and an electronic patient status led to redesign of our EMR system, which had been in use for over 8 years at the Academic Medical Center of Amsterdam. The aim of this study was to understand whether the redesigned EMR system was an improvement of the earlier EMR and which system aspects accounted for user satisfaction and which did not. We conducted a formative pre- and post usability evaluation of our former and redesigned EMR system. For the assessment of both system versions' usability, we distributed two standardized usability questionnaires among 150 clinicians who routinely had used the older EMR system and had been working with its newer version for 6 weeks. Though overall user satisfaction was relatively high for both EMR systems, screen layout and interaction structure proved less easy to work with in the newer EMR system. The new EMR system however was more appreciated because of its enhanced functionality, capabilities and likeable user-interface. The results point to a number of actions that might be useful in future usability improvement efforts of our EMR system and other EMRs.

  2. Developing a quit smoking website that is usable by people with severe mental illnesses.

    PubMed

    Ferron, Joelle C; Brunette, Mary F; McHugo, Gregory J; Devitt, Timothy S; Martin, Wendy M; Drake, Robert E

    2011-01-01

    Evidence-based treatments may be delivered in computerized, web-based formats. This strategy can deliver the intervention consistently with minimal treatment provider time and cost. However, standard web sites may not be usable by people with severe mental illnesses who may experience cognitive deficits and low computer experience. This manuscript reports on the iterative development and usability testing of a website designed to educate and motivate adults with severe mental illnesses to engage in smoking cessation activities. Three phases of semi-structured interviews were performed with participants after they used the program and combined with information from screen-recorded usability data. T-tests compared the differences between uses of the first computer program version and a later version. Iteratively conducted usability tests demonstrated an increased ease of use from the first to the last version of the website through significant improvement in the percentage of unproductive clicking along with fewer questions asked about how to use the program. The improvement in use of the website resulted from changes such as: integrating a mouse tutorial, increasing font sizes, and increasing button sizes. The website usability recommendations provide some guidelines for interventionists developing web tools for people who experience serious psychiatric disabilities. In general, insights from the study highlight the need for thoughtful design and usability testing when creating a website for people with severe mental illness.

  3. Advanced Digital Signal Processing for Hybrid Lidar

    DTIC Science & Technology

    2012-12-31

    usable range of hybrid lidar-radar in a turbid underwater environment. In a highly scattering enviromnent, many photons reaching the detector will...have scattered off particulates in the water, while relatively few photons reaching the detector will have made the round-trip to and from the object...Received power is attenuated according to where P is the power received by the detector , PQIS the power transmitted by the source, c is the beam

  4. Agriculture, Levels 1-4. Agriculture & Commercial Horticulture, Levels 1-4. Commercial Horticulture, Levels 1-3. Environmental Conservation, Levels 2-4. National Vocational Qualifications.

    ERIC Educational Resources Information Center

    Business and Technology Education Council, London (England).

    Britain's National Vocational Qualifications (NVQs) are work qualifications that measure what an employee or potential employee can do as well as how much he or she knows and understands about a particular job. Used as written proof of usable workplace skills that can be put to profitable use by an employer, NVQs range from basic Level 1, for…

  5. 50 Mb/s, 220-mW Laser-Array Transmitter

    NASA Technical Reports Server (NTRS)

    Cornwell, Donald M., Jr.

    1992-01-01

    Laser transmitter based on injection locking produces single-wavelength, diffraction-limited, single-lobe beam. Output stage is array of laser diodes producing non-diffraction-limited, multi-mode beam in absence of injection locking. Suitable for both free-space and optical-fiber communication systems. Because beam from transmitter focused to spot as small as 5 micrometers, devices usable for reading and writing optical disks at increased information densities. Application also in remote sensing and ranging.

  6. Evaluation of the reliability, usability, and applicability of AMSTAR, AMSTAR 2, and ROBIS: protocol for a descriptive analytic study.

    PubMed

    Gates, Allison; Gates, Michelle; Duarte, Gonçalo; Cary, Maria; Becker, Monika; Prediger, Barbara; Vandermeer, Ben; Fernandes, Ricardo M; Pieper, Dawid; Hartling, Lisa

    2018-06-13

    Systematic reviews (SRs) of randomised controlled trials (RCTs) can provide the best evidence to inform decision-making, but their methodological and reporting quality varies. Tools exist to guide the critical appraisal of quality and risk of bias in SRs, but evaluations of their measurement properties are limited. We will investigate the interrater reliability (IRR), usability, and applicability of A MeaSurement Tool to Assess systematic Reviews (AMSTAR), AMSTAR 2, and Risk Of Bias In Systematic reviews (ROBIS) for SRs in the fields of biomedicine and public health. An international team of researchers at three collaborating centres will undertake the study. We will use a random sample of 30 SRs of RCTs investigating therapeutic interventions indexed in MEDLINE in February 2014. Two reviewers at each centre will appraise the quality and risk of bias in each SR using AMSTAR, AMSTAR 2, and ROBIS. We will record the time to complete each assessment and for the two reviewers to reach consensus for each SR. We will extract the descriptive characteristics of each SR, the included studies, participants, interventions, and comparators. We will also extract the direction and strength of the results and conclusions for the primary outcome. We will summarise the descriptive characteristics of the SRs using means and standard deviations, or frequencies and proportions. To test for interrater reliability between reviewers and between the consensus agreements of reviewer pairs, we will use Gwet's AC 1 statistic. For comparability to previous evaluations, we will also calculate weighted Cohen's kappa and Fleiss' kappa statistics. To estimate usability, we will calculate the mean time to complete the appraisal and to reach consensus for each tool. To inform applications of the tools, we will test for statistical associations between quality scores and risk of bias judgments, and the results and conclusions of the SRs. Appraising the methodological and reporting quality of SRs is necessary to determine the trustworthiness of their conclusions. Which tool may be most reliably applied and how the appraisals should be used is uncertain; the usability of newly developed tools is unknown. This investigation of common (AMSTAR) and newly developed (AMSTAR 2, ROBIS) tools will provide empiric data to inform their application, interpretation, and refinement.

  7. Reactome diagram viewer: data structures and strategies to boost performance.

    PubMed

    Fabregat, Antonio; Sidiropoulos, Konstantinos; Viteri, Guilherme; Marin-Garcia, Pablo; Ping, Peipei; Stein, Lincoln; D'Eustachio, Peter; Hermjakob, Henning

    2018-04-01

    Reactome is a free, open-source, open-data, curated and peer-reviewed knowledgebase of biomolecular pathways. For web-based pathway visualization, Reactome uses a custom pathway diagram viewer that has been evolved over the past years. Here, we present comprehensive enhancements in usability and performance based on extensive usability testing sessions and technology developments, aiming to optimize the viewer towards the needs of the community. The pathway diagram viewer version 3 achieves consistently better performance, loading and rendering of 97% of the diagrams in Reactome in less than 1 s. Combining the multi-layer html5 canvas strategy with a space partitioning data structure minimizes CPU workload, enabling the introduction of new features that further enhance user experience. Through the use of highly optimized data structures and algorithms, Reactome has boosted the performance and usability of the new pathway diagram viewer, providing a robust, scalable and easy-to-integrate solution to pathway visualization. As graph-based visualization of complex data is a frequent challenge in bioinformatics, many of the individual strategies presented here are applicable to a wide range of web-based bioinformatics resources. Reactome is available online at: https://reactome.org. The diagram viewer is part of the Reactome pathway browser (https://reactome.org/PathwayBrowser/) and also available as a stand-alone widget at: https://reactome.org/dev/diagram/. The source code is freely available at: https://github.com/reactome-pwp/diagram. fabregat@ebi.ac.uk or hhe@ebi.ac.uk. Supplementary data are available at Bioinformatics online.

  8. Evaluating a Modular Decision Support Application for Colorectal Cancer Screening

    PubMed Central

    Diiulio, Julie B.; Borders, Morgan R.; Sushereba, Christen E.; Saleem, Jason J.; Haverkamp, Donald; Imperiale, Thomas F.

    2017-01-01

    Summary Background There is a need for health information technology evaluation that goes beyond randomized controlled trials to include consideration of usability, cognition, feedback from representative users, and impact on efficiency, data quality, and clinical workflow. This article presents an evaluation illustrating one approach to this need using the Decision-Centered Design framework. Objective To evaluate, through a Decision-Centered Design framework, the ability of the Screening and Surveillance App to support primary care clinicians in tracking and managing colorectal cancer testing. Methods We leveraged two evaluation formats, online and in-person, to obtain feedback from a range primary care clinicians and obtain comparative data. Both the online and in-person evaluations used mock patient data to simulate challenging patient scenarios. Primary care clinicians responded to a series of colorectal cancer-related questions about each patient and made recommendations for screening. We collected data on performance, perceived workload, and usability. Key elements of Decision-Centered Design include evaluation in the context of realistic, challenging scenarios and measures designed to explore impact on cognitive performance. Results Comparison of means revealed increases in accuracy, efficiency, and usability and decreases in perceived mental effort and workload when using the Screening and Surveillance App. Conclusion The results speak to the benefits of using the Decision-Centered Design approach in the analysis, design, and evaluation of Health Information Technology. Furthermore, the Screening and Surveillance App shows promise for filling decision support gaps in current electronic health records. PMID:28197619

  9. Usability Evaluation of the Student Centered e-Learning Environment

    ERIC Educational Resources Information Center

    Junus, Inas Sofiyah; Santoso, Harry Budi; Isal, R. Yugo K.; Utomo, Andika Yudha

    2015-01-01

    Student Centered e-Learning Environment (SCeLE) has substantial roles to support learning activities at Faculty of Computer Science, Universitas Indonesia (Fasilkom UI). Although it has been utilized for about 10 years, the usability aspect of SCeLE as an e-Learning system has not been evaluated. Therefore, the usability aspects of SCeLE Fasilkom…

  10. Patterns for Success: A Lesson in Usable Design from U.S. Patent Records.

    ERIC Educational Resources Information Center

    Durack, Katherine T.

    1997-01-01

    Investigates the design history of women's household sewing patterns as that history is recorded in United States Patent Records. Finds that the history of home sewing patterns illustrates a key aspect of usable design: the interrelationship between a device and its documentation and the way changes to both enhance overall product usability. (RS)

  11. Usability Assessment of Educational Software by Students: Case of "?Pón-Ìm?`" in Osun State, Nigeria

    ERIC Educational Resources Information Center

    Tijani, O. K.

    2016-01-01

    This study investigated usability of educational software: case of "?pón-Ìm?`" in Osun state, Nigeria. Specifically, the study investigated influences of gender and school locations on students' assessment of "?pón-Ìm?`" Technology Enhanced Learning System (OTELS) based on selected usability parameters. 701 students were…

  12. An Examination of Usability of a Virtual Environment for Students Enrolled in a College of Agriculture

    ERIC Educational Resources Information Center

    Murphrey, Theresa Pesl; Rutherford, Tracy A.; Doerfert, David L.; Edgar, Leslie D.; Edgar, Don W.

    2014-01-01

    Educational technology continues to expand with multi-user virtual environments (e.g., Second Life™) being the latest technology. Understanding a virtual environment's usability can enhance educational planning and effective use. Usability includes the interaction quality between an individual and the item being assessed. The purpose was to assess…

  13. User-Centered Design and Usability Testing of a Web Site: An Illustrative Case Study.

    ERIC Educational Resources Information Center

    Corry, Michael D.; Frick, Theodore W.; Hansen, Lisa

    1997-01-01

    Presents an overview of user-centered design and usability testing. Describes a Web site evaluation project at a university, the iterative process of rapid prototyping and usability testing, and how the findings helped to improve the design. Discusses recommendations for university Web site design and reflects on problems faced in usability…

  14. The Influence of Product Aesthetics and User State in Usability Testing

    ERIC Educational Resources Information Center

    Sauer, Juergen; Sonderegger, Andreas

    2011-01-01

    An empirical study examined the effects of two influencing factors in usability tests on user performance and usability ratings. Product aesthetics (high vs. low) as the main independent factor and prior usage event (positive vs. negative) as a subsidiary independent factor were varied in a between-participants design. 60 participants took part in…

  15. Evaluating the Usability of a Museum Web Site.

    ERIC Educational Resources Information Center

    Harms, Ilse; Schweibenz, Werner

    This paper presents a research project conducted by the Department of Information Science in cooperation with the Saarland Museum, the art museum of the Federal State of Saarland, Germany. The study had two aims. The first was to evaluate some methods of usability engineering for the Web, and the second was to evaluate the usability of the…

  16. A Usability Study of Users' Perceptions toward a Multimedia Computer-Assisted Learning Tool for Neuroanatomy

    ERIC Educational Resources Information Center

    Gould, Douglas J.; Terrell, Mark A.; Fleming, Jo

    2008-01-01

    This usability study evaluated users' perceptions of a multimedia prototype for a new e-learning tool: Anatomy of the Central Nervous System: A Multimedia Course. Usability testing is a collection of formative evaluation methods that inform the developmental design of e-learning tools to maximize user acceptance, satisfaction, and adoption.…

  17. The Relationship between National Culture and the Usability of an E-Learning System

    ERIC Educational Resources Information Center

    Adeoye, Blessing; Wentling, Rose Mary

    2007-01-01

    The purpose of this study was to investigate possible relationships between national culture and the usability of an e-learning system. The theoretical frameworks that were used to guide this study were Hofstede's (1980) cultural dimensions, and Nielson's (1993) usability attributes. The sample for this study was composed of 24 international…

  18. The effect of sampling rate and anti-aliasing filters on high-frequency response spectra

    USGS Publications Warehouse

    Boore, David M.; Goulet, Christine

    2013-01-01

    The most commonly used intensity measure in ground-motion prediction equations is the pseudo-absolute response spectral acceleration (PSA), for response periods from 0.01 to 10 s (or frequencies from 0.1 to 100 Hz). PSAs are often derived from recorded ground motions, and these motions are usually filtered to remove high and low frequencies before the PSAs are computed. In this article we are only concerned with the removal of high frequencies. In modern digital recordings, this filtering corresponds at least to an anti-aliasing filter applied before conversion to digital values. Additional high-cut filtering is sometimes applied both to digital and to analog records to reduce high-frequency noise. Potential errors on the short-period (high-frequency) response spectral values are expected if the true ground motion has significant energy at frequencies above that of the anti-aliasing filter. This is especially important for areas where the instrumental sample rate and the associated anti-aliasing filter corner frequency (above which significant energy in the time series is removed) are low relative to the frequencies contained in the true ground motions. A ground-motion simulation study was conducted to investigate these effects and to develop guidance for defining the usable bandwidth for high-frequency PSA. The primary conclusion is that if the ratio of the maximum Fourier acceleration spectrum (FAS) to the FAS at a frequency fsaa corresponding to the start of the anti-aliasing filter is more than about 10, then PSA for frequencies above fsaa should be little affected by the recording process, because the ground-motion frequencies that control the response spectra will be less than fsaa . A second topic of this article concerns the resampling of the digital acceleration time series to a higher sample rate often used in the computation of short-period PSA. We confirm previous findings that sinc-function interpolation is preferred to the standard practice of using linear time interpolation for the resamplin

  19. Navigation in the electronic health record: A review of the safety and usability literature.

    PubMed

    Roman, Lisette C; Ancker, Jessica S; Johnson, Stephen B; Senathirajah, Yalini

    2017-03-01

    Inefficient navigation in electronic health records has been shown to increase users' cognitive load, which may increase potential for errors, reduce efficiency, and increase fatigue. However, navigation has received insufficient recognition and attention in the electronic health record (EHR) literature as an independent construct and contributor to overall usability. Our aims in this literature review were to (1) assess the prevalence of navigation-related topics within the EHR usability and safety research literature, (2) categorize types of navigation actions within the EHR, (3) capture relationships between these navigation actions and usability principles, and (4) collect terms and concepts related to EHR navigation. Our goal was to improve access to navigation-related research in usability. We applied scoping literature review search methods with the assistance of a reference librarian to identify articles published since 1996 that reported evaluation of the usability or safety of an EHR user interface via user test, analytic methods, or inspection methods. The 4336 references collected from MEDLINE, EMBASE, Engineering Village, and expert referrals were de-duplicated and screened for relevance, and navigation-related concepts were abstracted from the 21 articles eligible for review using a standard abstraction form. Of the 21 eligible articles, 20 (95%) mentioned navigation in results and discussion of usability evaluations. Navigation between pages of the EHR was the more frequently documented type of navigation (86%) compared to navigation within a single page (14%). Navigation actions (e.g., scrolling through a medication list) were frequently linked to specific usability heuristic violations, among which flexibility and efficiency of use, recognition rather than recall, and error prevention were most common. Discussion of navigation was prevalent in results across all types of evaluation methods among the articles reviewed. Navigating between multiple screens was frequently identified as a usability barrier. The lack of standard terminology created some challenges to identifying and comparing articles. We observed that usability researchers are frequently capturing navigation-related issues even in articles that did not explicitly state navigation as a focus. Capturing and synthesizing the literature on navigation is challenging because of the lack of uniform vocabulary. Navigation is a potential target for normative recommendations for improved interaction design for safer systems. Future research in this domain, including development of normative recommendations for usability design and evaluation, will be facilitated by development of a standard terminology for describing EHR navigation. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. 47 CFR 18.309 - Frequency range of measurements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... MEDICAL EQUIPMENT Technical Standards § 18.309 Frequency range of measurements. (a) For field strength measurements: Frequency band in which device operates (MHz) Range of frequency measurements Lowest frequency...

  1. Testing of an Annular Linear Induction Pump for the Fission Surface Power Technology Demonstration Unit

    NASA Technical Reports Server (NTRS)

    Polzin, K. A.; Pearson, J. B.; Webster, K.; Godfoy, T. J.; Bossard, J. A.

    2013-01-01

    Results of performance testing of an annular linear induction pump that has been designed for integration into a fission surface power technology demonstration unit are presented. The pump electromagnetically pushes liquid metal (NaK) through a specially-designed apparatus that permits quantification of pump performance over a range of operating conditions. Testing was conducted for frequencies of 40, 55, and 70 Hz, liquid metal temperatures of 125, 325, and 525 C, and input voltages from 30 to 120 V. Pump performance spanned a range of flow rates from roughly 0.3 to 3.1 L/s (4.8 to 49 gpm), and pressure heads of <1 to 104 kPa (<0.15 to 15 psi). The maximum efficiency measured during testing was 5.4%. At the technology demonstration unit operating temperature of 525 C the pump operated over a narrower envelope, with flow rates from 0.3 to 2.75 L/s (4.8 to 43.6 gpm), developed pressure heads from <1 to 55 kPa (<0.15 to 8 psi), and a maximum efficiency of 3.5%. The pump was supplied with three-phase power at 40 and 55 Hz using a variable-frequency motor drive, while power at 55 and 70 Hz was supplied using a variable-frequency power supply. Measured performance of the pump at 55 Hz using either supply exhibited good quantitative agreement. For a given temperature, the peak in efficiency occurred at different flow rates as the frequency was changed, but the maximum value of efficiency was relative insensitive within 0.3% over the frequency range tested, including a scan from 45 to 78 Hz. The objectives of the FSP technology project are as follows:5 • Develop FSP concepts that meet expected surface power requirements at reasonable cost with added benefits over other options. • Establish a nonnuclear hardware-based technical foundation for FSP design concepts to reduce overall development risk. • Reduce the cost uncertainties for FSP and establish greater credibility for flight system cost estimates. • Generate the key nonnuclear products to allow Agency decision makers to consider FSP as a viable option for potential future flight development. The pump must be compatible with the liquid NaK coolant and have adequate performance to enable a viable flight system. Idaho National Laboratory (INL) was tasked with the design and fabrication of an ALIP suitable for the FSP reference mission. Under the program, a quarter-scale FSP technology demonstration is under construction to test the end-to-end conversion of simulated nuclear thermal power to usable electrical power intended to raise the entire FSP system to Technology Readiness Level 6. An ALIP for this TDU was fabricated under the direction of the INL and shipped to NASA Marshall Space Flight Center (MSFC) for testing at representative operating conditions. This pump was designed to meet the requirements of the TDU experiment. The ALIP test circuit (ATC) at MSFC, previously used to conduct performance evaluation on another ALIP6 was used to test the present TDU pump for the FSP Technology Development program.

  2. Applying User-Centered Design Methods to the Development of an mHealth Application for Use in the Hospital Setting by Patients and Care Partners.

    PubMed

    Couture, Brittany; Lilley, Elizabeth; Chang, Frank; DeBord Smith, Ann; Cleveland, Jessica; Ergai, Awatef; Katsulis, Zachary; Benneyan, James; Gershanik, Esteban; Bates, David W; Collins, Sarah A

    2018-04-01

     Developing an optimized and user-friendly mHealth application for patients and family members in the hospital environment presents unique challenges given the diverse patient population and patients' various states of well-being.  This article describes user-centered design methods and results for developing the patient and family facing user interface and functionality of MySafeCare, a safety reporting tool for hospitalized patients and their family members.  Individual and group usability sessions were conducted with specific testing scenarios for participants to follow to test the usability and functionality of the tool. Participants included patients, family members, and Patient and Family Advisory Council (PFAC) members. Engagement rounds were also conducted on study units and lessons learned provided additional information to the usability work. Usability results were aligned with Nielsen's Usability Heuristics.  Eleven patients and family members and 25 PFAC members participated in usability testing and over 250 patients and family members were engaged during research team rounding. Specific themes resulting from the usability testing sessions influenced the changes made to the user interface design, workflow functionality, and terminology.  User-centered design should focus on workflow functionality, terminology, and user interface issues for mHealth applications. These themes illustrated issues aligned with four of Nielsen's Usability Heuristics: match between system and the real world, consistency and standards, flexibility and efficiency of use, and aesthetic and minimalist design. We identified workflow and terminology issues that may be specific to the use of an mHealth application focused on safety and used by hospitalized patients and their families. Schattauer GmbH Stuttgart.

  3. How you spend your pennies ... factors affecting the efficiency of human waste disposal systems (re-usable and disposable) and their cost.

    PubMed

    Rollnick, M

    1991-05-01

    Both re-usable and disposable systems have their merits and problems. The disposable system, being fully integrated, appears to be steadily gaining market share compared with the re-usable system. Since its introduction, the success of the re-usable system has been limited by the use of pans not designed for automatic processing. Where the 'perfection' pan has been superseded by 'open' shaped receptacles and those used in commode chairs, cleaning effectiveness can be improved by a factor of 10. For this and other reasons, nursing involvement in the re-usable system can be high while the 'perfection' pan is in use. A work study exercise to compare nursing involvement in re-usable and disposable systems is under way. When selecting a human waste disposal system for any site, it is vital that all disciplines discuss and decide objectives. The equipment usage, space, site conditions, availability and quality of supplies (eg water, electricity), the costs of maintenance, nursing time and other expenditure must be considered. The disposable system is capable of high process rates (more than double that of the fastest re-usable system). Its capital cost is currently about 1,000 pounds less than an average re-usable system, but in the busiest wards, revenue costs may be higher. In such wards the space for disposable receptacle storage can be as much as five to ten times machine volume. The design of macerators is generally simpler (having less components) than washer-disinfectors. Monitoring and maintenance involvement are likewise expected to be lower, particularly in hospitals with modern drainage systems.(ABSTRACT TRUNCATED AT 250 WORDS)

  4. Comparison of heuristic and cognitive walkthrough usability evaluation methods for evaluating health information systems.

    PubMed

    Khajouei, Reza; Zahiri Esfahani, Misagh; Jahani, Yunes

    2017-04-01

    There are several user-based and expert-based usability evaluation methods that may perform differently according to the context in which they are used. The objective of this study was to compare 2 expert-based methods, heuristic evaluation (HE) and cognitive walkthrough (CW), for evaluating usability of health care information systems. Five evaluators independently evaluated a medical office management system using HE and CW. We compared the 2 methods in terms of the number of identified usability problems, their severity, and the coverage of each method. In total, 156 problems were identified using the 2 methods. HE identified a significantly higher number of problems related to the "satisfaction" attribute ( P  = .002). The number of problems identified using CW concerning the "learnability" attribute was significantly higher than those identified using HE ( P  = .005). There was no significant difference between the number of problems identified by HE, based on different usability attributes ( P  = .232). Results of CW showed a significant difference between the number of problems related to usability attributes ( P  < .0001). The average severity of problems identified using CW was significantly higher than that of HE ( P  < .0001). This study showed that HE and CW do not differ significantly in terms of the number of usability problems identified, but they differ based on the severity of problems and the coverage of some usability attributes. The results suggest that CW would be the preferred method for evaluating systems intended for novice users and HE for users who have experience with similar systems. However, more studies are needed to support this finding. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  5. Quantifying usability: an evaluation of a diabetes mHealth system on effectiveness, efficiency, and satisfaction metrics with associated user characteristics.

    PubMed

    Georgsson, Mattias; Staggers, Nancy

    2016-01-01

    Mobile health (mHealth) systems are becoming more common for chronic disease management, but usability studies are still needed on patients' perspectives and mHealth interaction performance. This deficiency is addressed by our quantitative usability study of a mHealth diabetes system evaluating patients' task performance, satisfaction, and the relationship of these measures to user characteristics. We used metrics in the International Organization for Standardization (ISO) 9241-11 standard. After standardized training, 10 patients performed representative tasks and were assessed on individual task success, errors, efficiency (time on task), satisfaction (System Usability Scale [SUS]) and user characteristics. Tasks of exporting and correcting values proved the most difficult, had the most errors, the lowest task success rates, and consumed the longest times on task. The average SUS satisfaction score was 80.5, indicating good but not excellent system usability. Data trends showed males were more successful in task completion, and younger participants had higher performance scores. Educational level did not influence performance, but a more recent diabetes diagnosis did. Patients with more experience in information technology (IT) also had higher performance rates. Difficult task performance indicated areas for redesign. Our methods can assist others in identifying areas in need of improvement. Data about user background and IT skills also showed how user characteristics influence performance and can provide future considerations for targeted mHealth designs. Using the ISO 9241-11 usability standard, the SUS instrument for satisfaction and measuring user characteristics provided objective measures of patients' experienced usability. These could serve as an exemplar for standardized, quantitative methods for usability studies on mHealth systems. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association.

  6. Towards Usable E-Health. A Systematic Review of Usability Questionnaires.

    PubMed

    Sousa, Vanessa E C; Dunn Lopez, Karen

    2017-05-10

    The use of e-health can lead to several positive outcomes. However, the potential for e-health to improve healthcare is partially dependent on its ease of use. In order to determine the usability for any technology, rigorously developed and appropriate measures must be chosen. To identify psychometrically tested questionnaires that measure usability of e-health tools, and to appraise their generalizability, attributes coverage, and quality. We conducted a systematic review of studies that measured usability of e-health tools using four databases (Scopus, PubMed, CINAHL, and HAPI). Non-primary research, studies that did not report measures, studies with children or people with cognitive limitations, and studies about assistive devices or medical equipment were systematically excluded. Two authors independently extracted information including: questionnaire name, number of questions, scoring method, item generation, and psychometrics using a data extraction tool with pre-established categories and a quality appraisal scoring table. Using a broad search strategy, 5,558 potentially relevant papers were identified. After removing duplicates and applying exclusion criteria, 35 articles remained that used 15 unique questionnaires. From the 15 questionnaires, only 5 were general enough to be used across studies. Usability attributes covered by the questionnaires were: learnability (15), efficiency (12), and satisfaction (11). Memorability (1) was the least covered attribute. Quality appraisal showed that face/content (14) and construct (7) validity were the most frequent types of validity assessed. All questionnaires reported reliability measurement. Some questionnaires scored low in the quality appraisal for the following reasons: limited validity testing (7), small sample size (3), no reporting of user centeredness (9) or feasibility estimates of time, effort, and expense (7). Existing questionnaires provide a foundation for research on e-health usability. However, future research is needed to broaden the coverage of the usability attributes and psychometric properties of the available questionnaires.

  7. Usability and feasibility of health IT interventions to enhance Self-Care for Lymphedema Symptom Management in breast cancer survivors.

    PubMed

    Fu, Mei R; Axelrod, Deborah; Guth, Amber A; Wang, Yao; Scagliola, Joan; Hiotis, Karen; Rampertaap, Kavita; El-Shammaa, Nardin

    2016-09-01

    The-Optimal-Lymph-Flow health IT system (TOLF) is a patient-centered, web-and-mobile-based educational and behavioral health IT system focusing on safe, innovative, and pragmatic self-care strategies for lymphedema symptom management. The purpose of this study was to evaluate usability, feasibility, and acceptability of TOLF among the end-user of breast cancer survivors. Two types of usability testing were completed with 30 breast cancer survivors: heuristic evaluation and end-user testing. Each participant was asked to think aloud while completing a set of specified tasks designed to explicate and freely explore the system features. A heuristic evaluation checklist, the Perceived Ease of Use and Usefulness Questionnaire, and The Post Study System Usability Questionnaire were used to evaluate usability of the system. Open-ended questions were used to gather qualitative data. Quantitative data were analyzed using descriptive statistics and qualitative data were summarized thematically. Breast cancer survivors were very satisfied with the system: 90% (n = 27) rated the system having no usability problems; 10% (n = 3) noted minor cosmetic problems: spelling errors or text font size. The majority of participants 96.6% (n = 29) strongly agreed that the system was easy to use and effective in helping to learn about lymphedema, symptoms and self-care strategies. Themes from the qualitative data included empowerment, high quality information, loving avatar simulation videos, easy accessibility, and user-friendliness. This usability study provided evidence on breast cancer survivor's acceptance and highly positive evaluation of TOLF's usability as well as feasibility of using technologically-driven delivery model to enhance self-care strategies for lymphedema symptom management.

  8. Quantifying usability: an evaluation of a diabetes mHealth system on effectiveness, efficiency, and satisfaction metrics with associated user characteristics

    PubMed Central

    Staggers, Nancy

    2016-01-01

    Objective Mobile health (mHealth) systems are becoming more common for chronic disease management, but usability studies are still needed on patients’ perspectives and mHealth interaction performance. This deficiency is addressed by our quantitative usability study of a mHealth diabetes system evaluating patients’ task performance, satisfaction, and the relationship of these measures to user characteristics. Materials and Methods We used metrics in the International Organization for Standardization (ISO) 9241-11 standard. After standardized training, 10 patients performed representative tasks and were assessed on individual task success, errors, efficiency (time on task), satisfaction (System Usability Scale [SUS]) and user characteristics. Results Tasks of exporting and correcting values proved the most difficult, had the most errors, the lowest task success rates, and consumed the longest times on task. The average SUS satisfaction score was 80.5, indicating good but not excellent system usability. Data trends showed males were more successful in task completion, and younger participants had higher performance scores. Educational level did not influence performance, but a more recent diabetes diagnosis did. Patients with more experience in information technology (IT) also had higher performance rates. Discussion Difficult task performance indicated areas for redesign. Our methods can assist others in identifying areas in need of improvement. Data about user background and IT skills also showed how user characteristics influence performance and can provide future considerations for targeted mHealth designs. Conclusion Using the ISO 9241-11 usability standard, the SUS instrument for satisfaction and measuring user characteristics provided objective measures of patients’ experienced usability. These could serve as an exemplar for standardized, quantitative methods for usability studies on mHealth systems. PMID:26377990

  9. Evidence-based Heuristics for Evaluating Demands on eHealth Literacy and Usability in a Mobile Consumer Health Application.

    PubMed

    Monkman, Helen; Griffith, Janessa; Kushniruk, Andre W

    2015-01-01

    Heuristic evaluations have proven to be valuable for identifying usability issues in systems. Commonly used sets of heuritics exist; however, they may not always be the most suitable, given the specific goal of the analysis. One such example is seeking to evaluate the demands on eHealth literacy and usability of consumer health information systems. In this study, eight essential heuristics and three optional heuristics subsumed from the evidence on eHealth/health literacy and usability were tested for their utility in assessing a mobile blood pressure tracking application (app). This evaluation revealed a variety of ways the design of the app could both benefit and impede users with limited eHealth literacy. This study demonstrated the utility of a low-cost, single evaluation approach for identifying both eHealth literacy and usability issues based on existing evidence in the literature.

  10. Usability Laboratory Test of a Novel Mobile Homecare Application with Experienced Home Help Service Staff

    PubMed Central

    Scandurra, I; Hägglund, M; Koch, S; Lind, M

    2008-01-01

    Using participatory design, we developed and deployed a mobile Virtual Health Record (VHR) on a personal digital assistant (PDA) together with experienced homecare staff. To assess transferability to a second setting and usability when used by novice users with limited system education the application was tested in a usability lab. Eight participants from another homecare district performed tasks related to daily homecare work using the VHR. Test protocols were analyzed with regard to effectiveness, potential usability problems and user satisfaction. Usability problems having impact on system performance and contextual factors affecting system transferability were uncovered. Questionnaires revealed that the participants frequently used computers, but never PDAs. Surprisingly there were only minor differences in input efficiency between novice and experienced users. The participants were overall satisfied with the application. However, transfer to another district can not be performed, unless by means of careful field observations of contextual differences. PMID:19415140

  11. Development and evaluation of RAMP I - a practitioner's tool for screening of musculoskeletal disorder risk factors in manual handling.

    PubMed

    Lind, Carl Mikael; Forsman, Mikael; Rose, Linda Maria

    2017-10-16

    RAMP I is a screening tool developed to support practitioners in screening for work-related musculoskeletal disorder risk factors related to manual handling. RAMP I, which is part of the RAMP tool, is based on research-based studies combined with expert group judgments. More than 80 practitioners participated in the development of RAMP I. The tool consists of dichotomous assessment items grouped into seven categories. Acceptable reliability was found for a majority of the assessment items for 15 practitioners who were given 1 h of training. The usability evaluation points to RAMP I being usable for screening for musculoskeletal disorder risk factors, i.e., usable for assessing risks, being usable as a decision base, having clear results and that the time needed for an assessment is acceptable. It is concluded that RAMP I is a usable tool for practitioners.

  12. Bus use and older people: a literature review applying the Person-Environment-Occupation model in macro practice.

    PubMed

    Broome, Kieran; McKenna, Kryss; Fleming, Jennifer; Worrall, Linda

    2009-03-01

    The same reasons that prompt older people to give up driving can also result in difficulties with accessing public transport. Difficulties using public transport can limit older people's participation in society, thereby impacting negatively on their health. Focusing on public buses, this review explicates the link between bus usability and the health of older people and frames existing evidence on bus usability issues. The Person-Environment-Occupation (PEO) model offers a framework by which bus usability can be assessed. A combination of person-centred, environmental, and occupation-related factors, including bus design, service provision and performance, information, and the attitudes of staff and the community, impact on older people's ability to catch buses. More systematic research needs to take place in order to develop a comprehensive understanding of bus usability. Occupational therapy has a key role to play in conceptualizing, implementing, and evaluating improvements in bus usability for older people.

  13. Using a medical simulation center as an electronic health record usability laboratory

    PubMed Central

    Landman, Adam B; Redden, Lisa; Neri, Pamela; Poole, Stephen; Horsky, Jan; Raja, Ali S; Pozner, Charles N; Schiff, Gordon; Poon, Eric G

    2014-01-01

    Usability testing is increasingly being recognized as a way to increase the usability and safety of health information technology (HIT). Medical simulation centers can serve as testing environments for HIT usability studies. We integrated the quality assurance version of our emergency department (ED) electronic health record (EHR) into our medical simulation center and piloted a clinical care scenario in which emergency medicine resident physicians evaluated a simulated ED patient and documented electronically using the ED EHR. Meticulous planning and close collaboration with expert simulation staff was important for designing test scenarios, pilot testing, and running the sessions. Similarly, working with information systems teams was important for integration of the EHR. Electronic tools are needed to facilitate entry of fictitious clinical results while the simulation scenario is unfolding. EHRs can be successfully integrated into existing simulation centers, which may provide realistic environments for usability testing, training, and evaluation of human–computer interactions. PMID:24249778

  14. Integrating Low-Cost Rapid Usability Testing into Agile System Development of Healthcare IT: A Methodological Perspective.

    PubMed

    Kushniruk, Andre W; Borycki, Elizabeth M

    2015-01-01

    The development of more usable and effective healthcare information systems has become a critical issue. In the software industry methodologies such as agile and iterative development processes have emerged to lead to more effective and usable systems. These approaches highlight focusing on user needs and promoting iterative and flexible development practices. Evaluation and testing of iterative agile development cycles is considered an important part of the agile methodology and iterative processes for system design and re-design. However, the issue of how to effectively integrate usability testing methods into rapid and flexible agile design cycles has remained to be fully explored. In this paper we describe our application of an approach known as low-cost rapid usability testing as it has been applied within agile system development in healthcare. The advantages of the integrative approach are described, along with current methodological considerations.

  15. Analysis of usability factors affecting purchase intention in online e-commerce sites

    NASA Astrophysics Data System (ADS)

    Perdana, R. A.; Suzianti, A.

    2017-03-01

    The growing number of internet users plays a significant role in the emergence of a variety of online e-commerce sites to meet the needs of Indonesians. However, there are still some problems faced by the users in using e-commerce sites. Therefore, a research related to user experience on their purchase intention to foster e-commerce sites is required. This study is conducted to find out the relationship between usability factors on e-commerce users’ purchase intention using a case study by using SEM to analyse the usability of the website. The result of this study shows that credibility, readability and telepresence are usability factors that directly affect purchase intention, while simplicity, consistency and interactivity are usability factors that indirectly affect purchase intention. Therefore, we can conclude that Indonesian consumers are on the Early Majority phase in adopting Company A.

  16. Evaluation of a Web-Based App Demonstrating an Exclusionary Algorithmic Approach to TNM Cancer Staging

    PubMed Central

    2015-01-01

    Background TNM staging plays a critical role in the evaluation and management of a range of different types of cancers. The conventional combinatorial approach to the determination of an anatomic stage relies on the identification of distinct tumor (T), node (N), and metastasis (M) classifications to generate a TNM grouping. This process is inherently inefficient due to the need for scrupulous review of the criteria specified for each classification to ensure accurate assignment. An exclusionary approach to TNM staging based on sequential constraint of options may serve to minimize the number of classifications that need to be reviewed to accurately determine an anatomic stage. Objective Our aim was to evaluate the usability and utility of a Web-based app configured to demonstrate an exclusionary approach to TNM staging. Methods Internal medicine residents, surgery residents, and oncology fellows engaged in clinical training were asked to evaluate a Web-based app developed as an instructional aid incorporating (1) an exclusionary algorithm that polls tabulated classifications and sorts them into ranked order based on frequency counts, (2) reconfiguration of classification criteria to generate disambiguated yes/no questions that function as selection and exclusion prompts, and (3) a selectable grid of TNM groupings that provides dynamic graphic demonstration of the effects of sequentially selecting or excluding specific classifications. Subjects were asked to evaluate the performance of this app after completing exercises simulating the staging of different types of cancers encountered during training. Results Survey responses indicated high levels of agreement with statements supporting the usability and utility of this app. Subjects reported that its user interface provided a clear display with intuitive controls and that the exclusionary approach to TNM staging it demonstrated represented an efficient process of assignment that helped to clarify distinctions between tumor, node, and metastasis classifications. High overall usefulness ratings were bolstered by supplementary comments suggesting that this app might be readily adopted for use in clinical practice. Conclusions A Web-based app that utilizes an exclusionary algorithm to prompt the assignment of tumor, node, and metastasis classifications may serve as an effective instructional aid demonstrating an efficient and informative approach to TNM staging. PMID:28410163

  17. Design and electrical performance of CdS/Sb2Te3 tunneling heterojunction devices

    NASA Astrophysics Data System (ADS)

    Khusayfan, Najla M.; Qasrawi, A. F.; Khanfar, Hazem K.

    2018-02-01

    In the current work, a tunneling barrier device made of 20 nm thick Sb2Te3 layer deposited onto 500 nm thick CdS is designed and characterized. The design included a Yb metallic substrate and Ag point contact of area of 10-3 cm2. The heterojunction properties are investigated by means of x-ray diffraction and impedance spectroscopy techniques. It is observed that the coating of the Sb2Te3 onto the surface of CdS causes a further deformation to the already strained structure of hexagonal CdS. The designed energy band diagram for the CdS/Sb2Te3 suggests a straddling type of heterojunction with an estimated conduction and valence band offsets of 0.35 and 1.74 eV, respectively. In addition, the analysis of the capacitance-voltage characteristic curve revealed a depletion region width of 14 nm. On the other hand, the capacitance and conductivity spectra which are analyzed in the frequency domain of 0.001-1.80 GHz indicated that the conduction in the device is dominated by the quantum mechanical tunneling in the region below 0.26 GHz and by the correlated barrier hopping in the remaining region. While the modeling of the conductivity spectra allowed investigation of the density of states near Fermi levels and an average scattering time of 1.0 ns, the capacitance spectra exhibited resonance at 0.26 GHz followed by negative differential capacitance effect in the frequency domain of 0.26-1.8 GHz. Furthermore, the evaluation of the impedance and reflection coefficient spectra indicated the usability of these devices as wide range low pass filters with ideal values of voltage standing wave ratios.

  18. Validation of a Mobile Device for Acoustic Coordinated Reset Neuromodulation Tinnitus Therapy.

    PubMed

    Hauptmann, Christian; Wegener, Alexander; Poppe, Hendrik; Williams, Mark; Popelka, Gerald; Tass, Peter A

    2016-10-01

    Sound-based tinnitus intervention stimuli include broad-band noise signals with subjectively adjusted bandwidths used as maskers delivered by commercial devices or hearing aids, environmental sounds broadly described and delivered by both consumer devices and hearing aids, music recordings specifically modified and delivered in a variety of different ways, and other stimuli. Acoustic coordinated reset neuromodulation therapy for tinnitus reduction has unique and more stringent requirements compared to all other sound-based tinnitus interventions. These include precise characterization of tinnitus pitch and loudness, and effective provision of patient-controlled daily therapy signals at defined frequencies, levels, and durations outside of the clinic. The purpose of this study was to evaluate an approach to accommodate these requirements including evaluation of a mobile device, validation of an automated tinnitus pitch-matching algorithm and assessment of a patient's ability to control stimuli and collect repeated outcome measures. The experimental design involved direct laboratory measurements of the sound delivery capabilities of a mobile device, comparison of an automated, adaptive pitch-matching method to a traditional manual method and measures of a patient's ability to understand and manipulate a mobile device graphic user interface to both deliver the therapy signals and collect the outcome measures. This study consisted of 5 samples of a common mobile device for the laboratory measures and a total of 30 adult participants: 15 randomly selected normal-hearing participants with simulated tinnitus for validation of a tinnitus pitch-matching algorithm and 15 sequentially selected patients already undergoing tinnitus therapy for evaluation of patient usability. No tinnitus intervention(s) were specifically studied as a component of this study. Data collection involved laboratory measures of mobile devices, comparison of manual and automated adaptive tinnitus pitch-matching psychoacoustic procedures in the same participant analyzed for absolute differences (t test), variance differences (f test), and range comparisons, and assessment of patient usability including questionnaire measures and logs of patient observations. Mobile devices are able to reliably and accurately deliver the acoustic therapy signals. There was no difference in mean pitch matches (t test, p > 0.05) between an automated adaptive method compared to a traditional manual pitch-matching method. However, the variability of the automated pitch-matching method was much less (f test, p < 0.05) with twice as many matches within the predefined error range (±5%) compared to the manual pitch-matching method (80% versus 40%). After a short initial training, all participants were able to use the mobile device effectively and to perform the required tasks without further professional assistance. American Academy of Audiology

  19. First results of mapping sporadic E with a passive observing network

    NASA Astrophysics Data System (ADS)

    Rice, D. D.; Sojka, J. J.; Eccles, J. V.; Raitt, J. W.; Brady, J. J.; Hunsucker, R. D.

    2011-12-01

    Sporadic E (Es) can have dramatic effects on communications in the HF and low VHF range, producing over-the-horizon propagation for signals normally restricted to line-of-sight, and sometimes blocking F region propagation of signals in the lower HF range. Measuring the E region winds believed to produce Es is difficult, and no practical means of predicting Es occurrence currently exists other than statistical models. We describe a low-cost observing network based on software-controlled receivers that continuously watches for Es in near-real time using oblique HF propagation from existing transmitters. Results from an 11-day pilot campaign in July 2008 demonstrated that even a limited number of receivers in the network can readily determine the presence and extent of Es patches. These observations indicate that Es often develops quickly over regions of several hundred kilometers rather than gradually drifting across an area. These widespread Es “blooms” have been observed near winter solstice and occasionally at other times of the year; their lifetime depends on the season but can be several hours during the summer. The current network allows the extent of Es in portions of North America to be evaluated: the geographical distribution of Es and bounds on the density of the layer are inferred from its effects on the ionospheric maximum usable frequency (MUF). This study demonstrates quantitatively that Es mapping can provide information about Es layer geographical growth and decay. The observed sudden widespread Es blooms are space weather events that can have significant impact on HF/lower VHF communications and propagation model predictions.

  20. Professional Writing in the English Classroom: Let's Get Real--Using Usability to Connect Writers, Readers, and Texts

    ERIC Educational Resources Information Center

    Bush, Jonathan, Ed.; Zuidema, Leah, Ed.

    2012-01-01

    In professional writing, usability testing investigates how well users can find, understand, and use a document (Lannon). Usability testing involves gathering feedback from users, analyzing how successfully they used the document, and drawing on the test results to change or refine the design. From the authors' experiences as writers and teachers,…

Top