Sample records for utilising radiobiological measures

  1. Radiation-induced complications in prostate cancer patients treated with radiotherapy

    NASA Astrophysics Data System (ADS)

    Azuddin, A. Yusof; Rahman, I. Abdul; Siah, N. J.; Mohamed, F.; Saadc, M.; Ismail, F.

    2014-09-01

    The purpose of the study is to determine the relationship between radiation-induced complications with dosimetric and radiobiological parameters for prostate cancer patients that underwent the conformal radiotherapy treatment. 17 prostate cancer patients that have been treated with conformal radiotherapy were retrospectively analysed. The dosimetric data was retrieved in the form of dose-volume histogram (DVH) from Radiotherapy Treatment Planning System. The DVH was utilised to derived Normal Tissue Complication Probability (NTCP) in radiobiological data. Follow-up data from medical records were used to grade the occurrence of acute gastrointestinal (GI) and genitourinary (GU) complications using Radiation Therapy Oncology Group (RTOG) scoring system. The chi-square test was used to determine the relationship between radiation-induced complication with dosimetric and radiobiological parameters. 8 (47%) and 7 (41%) patients were having acute GI and GU complications respectively. The acute GI complication can be associated with V60rectum, rectal mean dose and NTCPrectum with p-value of 0.016, 0.038 and 0.049 respectively. There are no significant relationships of acute GU complication with dosimetric and radiobiological variables. Further study can be done by increase the sample size and follow up duration for deeper understanding of the factors that effecting the GU and GI complication in prostate cancer radiotherapy.

  2. Characterization and performances of DOSION, a dosimetry equipment dedicated to radiobiology experiments taking place at GANIL

    NASA Astrophysics Data System (ADS)

    Boissonnat, Guillaume; Fontbonne, Jean-Marc; Balanzat, Emmanuel; Boumard, Frederic; Carniol, Benjamin; Cassimi, Amine; Colin, Jean; Cussol, Daniel; Etasse, David; Fontbonne, Cathy; Frelin, Anne-Marie; Hommet, Jean; Salvador, Samuel

    2017-06-01

    Currently, radiobiology experiments using heavy ions at GANIL (Grand Accélérateur National d‧Ions Lourds) are conducted under the supervision of the CIMAP (Center for research on Ions, MAterials and Photonics). In this context, a new beam monitoring equipment named DOSION has been developed. It allows to perform measurements of accurate fluence and dose maps in near real time for each biological sample irradiated. In this paper, we present the detection system, its design, performances, calibration protocol and measurements performed during radiobiology experiments. This setup is currently available for any radiobiology experiments if one wishes to correlate one's own sample analysis to state-of-the-art dosimetric references.

  3. Microdosimetric investigation of a fast neutron radiobiology facility utilising the d(4)-9Be reaction.

    PubMed

    Waker, A J; Maughan, R L

    1986-11-01

    For fast neutron therapy and radiobiology beams, knowledge of the primary neutron spectrum is the most fundamental requirement for the definition of radiation quality. However, microdosimetric measurements in the form of single-event spectra not only complement the primary neutron spectrum as a statement of radiation quality but also provide a sensitive method of detecting changes in the radiation field in situations where it is no longer possible to have precise knowledge of the primary neutron spectrum, for example after collimator changes and in positions where the radiation field consists of a large scattered component. For the various collimator arrangements employed at the Gray Laboratory facility small perturbations of the radiation field are observed which can be related to a softening of the primary neutron spectrum with increasing field size of the collimator. Gamma fraction determinations are in very good agreement with measurements employing the dual chamber technique and also show small changes with collimator field size giving rise to gamma components ranging from 0.09 to 0.12, the higher values being measured for the larger field sizes. Quality changes represented by the shape of the measured event-size spectra and the derived microdosimetric parameters were greatest for off axis and phantom measurements. With increasing depth in water, yD was found to decrease from 47.3 keV micron-1 at 5 cm to 35.6 keV micron-1 at 15 cm depth, and the gamma fraction was found to increase from 0.23 to 0.40. Although there is no generally accepted and agreed method of relating microdosimetric information to biological effectiveness, the dual radiation theory in its original form (Kellerer and Rossi 1972) has been shown to be a very useful model for the assessment of the biological effectiveness of fast neutrons (Kellerer et al 1976). The microdosimetric parameter which is used in the dual radiation model is the dose mean specific energy corrected for saturation zeta* which, for a 2 micron simulated diameter, is related to the dose mean lineal energy corrected for saturation y* by zeta* = y* keV micron-1 X 0.51 X 10(-2) Gy. Values of y* determined for each of the collimator arrangements used at the Gray Laboratory show a spread of some 6% (table 1) and, as the dose fraction between lineal energies 5 and 150 keV micron-1 (the recoil proton component) do not alter by more than 3%, radiobiological experiments performed with different collimator arrangements would show no observable differences.(ABSTRACT TRUNCATED AT 400 WORDS)

  4. A radiobiology-based inverse treatment planning method for optimisation of permanent l-125 prostate implants in focal brachytherapy.

    PubMed

    Haworth, Annette; Mears, Christopher; Betts, John M; Reynolds, Hayley M; Tack, Guido; Leo, Kevin; Williams, Scott; Ebert, Martin A

    2016-01-07

    Treatment plans for ten patients, initially treated with a conventional approach to low dose-rate brachytherapy (LDR, 145 Gy to entire prostate), were compared with plans for the same patients created with an inverse-optimisation planning process utilising a biologically-based objective. The 'biological optimisation' considered a non-uniform distribution of tumour cell density through the prostate based on known and expected locations of the tumour. Using dose planning-objectives derived from our previous biological-model validation study, the volume of the urethra receiving 125% of the conventional prescription (145 Gy) was reduced from a median value of 64% to less than 8% whilst maintaining high values of TCP. On average, the number of planned seeds was reduced from 85 to less than 75. The robustness of plans to random seed displacements needs to be carefully considered when using contemporary seed placement techniques. We conclude that an inverse planning approach to LDR treatments, based on a biological objective, has the potential to maintain high rates of tumour control whilst minimising dose to healthy tissue. In future, the radiobiological model will be informed using multi-parametric MRI to provide a personalised medicine approach.

  5. A radiobiology-based inverse treatment planning method for optimisation of permanent l-125 prostate implants in focal brachytherapy

    NASA Astrophysics Data System (ADS)

    Haworth, Annette; Mears, Christopher; Betts, John M.; Reynolds, Hayley M.; Tack, Guido; Leo, Kevin; Williams, Scott; Ebert, Martin A.

    2016-01-01

    Treatment plans for ten patients, initially treated with a conventional approach to low dose-rate brachytherapy (LDR, 145 Gy to entire prostate), were compared with plans for the same patients created with an inverse-optimisation planning process utilising a biologically-based objective. The ‘biological optimisation’ considered a non-uniform distribution of tumour cell density through the prostate based on known and expected locations of the tumour. Using dose planning-objectives derived from our previous biological-model validation study, the volume of the urethra receiving 125% of the conventional prescription (145 Gy) was reduced from a median value of 64% to less than 8% whilst maintaining high values of TCP. On average, the number of planned seeds was reduced from 85 to less than 75. The robustness of plans to random seed displacements needs to be carefully considered when using contemporary seed placement techniques. We conclude that an inverse planning approach to LDR treatments, based on a biological objective, has the potential to maintain high rates of tumour control whilst minimising dose to healthy tissue. In future, the radiobiological model will be informed using multi-parametric MRI to provide a personalised medicine approach.

  6. Detailed characterization of the 1087 MeV/nucleon iron-56 beam used for radiobiology at the alternating gradient synchrotron

    NASA Technical Reports Server (NTRS)

    Zeitlin, C.; Heilbronn, L.; Miller, J.

    1998-01-01

    We report beam characterization and dosimetric measurements made using a 56Fe beam extracted from the Brookhaven National Laboratory Alternating Gradient Synchrotron (AGS) with a kinetic energy of 1087 MeV/nucleon. The measurements reveal that the depth-dose distribution of this beam differs significantly from that obtained with a 600 MeV/nucleon iron beam used in several earlier radiobiology experiments at the Lawrence Berkeley National Laboratory's BEVALAC. We present detailed measurements of beam parameters relevant for radiobiology, including track- and dose-averaged linear energy transfer (LET), fragment composition and LET spectra measured behind sample holders used in irradiations of biological samples. We also report measurements of fluence behind three depths (1.94, 4.68 and 9.35 g cm(-2)) of polyethylene targets with the 1087 MeV/nucleon beam, and behind 1.94 g cm(-2) of polyethylene with a 610 MeV/nucleon beam delivered by the AGS. These results are compared to earlier measurements with the 600 MeV/nucleon beam at the BEVALAC.

  7. Basic principles of molecular effects of irradiation.

    PubMed

    Selzer, Edgar; Hebar, Alexandra

    2012-02-01

    In order to understand the consequences of radiation a thorough understanding of the radiobiological mechanisms of the molecular up to the clinical level is of importance. Radiobiology therefore combines the basic principles of physics as well as biology and medicine and is concerned with the action of radiation from the subcellular level up to the living organism. Topics of interest and relevance are covered in much more broadness as is possible in the short following article in the literature to which the interested reader is referred to. Classical books in this field were written by Steel et al. (1989) as well as by Hall (1994). Topics usually covered by radiobiological reviews are the classification of different types of radiation, cell cycle dependency of radiation effects, types of radiation damage and cell death, dose response curves, measurement of radiation damage, the oxygen effect, relative biological effectiveness, the influence of dose rate, and several other important research areas. This short overview will concentrate on a subset of radiobiological topics of high importance and relative novelty.

  8. Dosimetry for radiobiological studies of the human hematopoietic system

    NASA Technical Reports Server (NTRS)

    Beck, W. L.; Stokes, T. R.; Lushbaugh, C. C.

    1972-01-01

    A system for estimating individual bone marrow doses in therapeutic radiation exposures of leukemia patients was studied. These measurements are used to make dose response correlations and to study the effect of dose protraction on peripheral blood cell levels. Three irradiators designed to produce a uniform field of high energy gamma radiation for total body exposures of large animals and man are also used for radiobiological studies.

  9. Animation and radiobiological analysis of 3D motion in conformal radiotherapy.

    PubMed

    MacKay, R I; Graham, P A; Moore, C J; Logue, J P; Sharrock, P J

    1999-07-01

    To allow treatment plans to be evaluated against the range of expected organ motion and set up error anticipated during treatment. Planning tools have been developed to allow concurrent animation and radiobiological analysis of three dimensional (3D) target and organ motion in conformal radiotherapy. Surfaces fitted to structures outlined on CT studies are projected onto pre-treatment images or onto megavoltage images collected during the patient treatment. Visual simulation of tumour and normal tissue movement is then performed by the application of three dimensional affine transformations, to the selected surface. Concurrent registration of the surface motion with the 3D dose distribution allows calculation of the change in dose to the volume. Realistic patterns of motion can be applied to the structure to simulate inter-fraction motion and set-up error. The biologically effective dose for the structure is calculated for each fraction as the surface moves over the course of the treatment and is used to calculate the normal tissue complication probability (NTCP) or tumour control probability (TCP) for the moving structure. The tool has been used to evaluate conformal therapy plans against set up measurements recorded during patient treatments. NTCP and TCP were calculated for a patient whose set up had been corrected after systematic deviations from plan geometry were measured during treatment, the effect of not making the correction were also assessed. TCP for the moving tumour was reduced if inadequate margins were set for the treatment. Modelling suggests that smaller margins could have been set for the set up corrected during the course of the treatment. The NTCP for the rectum was also higher for the uncorrected set up due to a more rectal tissue falling in the high dose region. This approach provides a simple way for clinical users to utilise information incrementally collected throughout the whole of a patient's treatment. In particular it is possible to test the robustness of a patient plan against a range of possible motion patterns. The methods described represent a move from the inspection of static pre-treatment plans to a review of the dynamic treatment.

  10. [From microdosimetry to nanodosimetry--the link between radiobiology and radiation physics].

    PubMed

    Fu, Yuchuan; Li, Ping

    2014-06-01

    The link between micro- and macro-parameters for radiation interactions that take place in living biological systems is described in this paper. Meanwhile recent progress and development in microdosimetry and nanodosimetry are introduced, including the methods to measure and calculate these micro- or nano-parameters. The relationship between radiobiology and physical quantities in microdosimetry and nanodosimetry was presented. Both the current problems on their applications in radiation protection and radiotherapy and the future development direction are proposed.

  11. New challenges in high-energy particle radiobiology

    PubMed Central

    2014-01-01

    Densely ionizing radiation has always been a main topic in radiobiology. In fact, α-particles and neutrons are sources of radiation exposure for the general population and workers in nuclear power plants. More recently, high-energy protons and heavy ions attracted a large interest for two applications: hadrontherapy in oncology and space radiation protection in manned space missions. For many years, studies concentrated on measurements of the relative biological effectiveness (RBE) of the energetic particles for different end points, especially cell killing (for radiotherapy) and carcinogenesis (for late effects). Although more recently, it has been shown that densely ionizing radiation elicits signalling pathways quite distinct from those involved in the cell and tissue response to photons. The response of the microenvironment to charged particles is therefore under scrutiny, and both the damage in the target and non-target tissues are relevant. The role of individual susceptibility in therapy and risk is obviously a major topic in radiation research in general, and for ion radiobiology as well. Particle radiobiology is therefore now entering into a new phase, where beyond RBE, the tissue response is considered. These results may open new applications for both cancer therapy and protection in deep space. PMID:24198199

  12. AFRRI Neutron Dosimetry and Radiobiology Conference

    DTIC Science & Technology

    1988-11-09

    Neutron Dosimetry and Radiobiology 8 - 9 November 1988 Sponsored by Defense Nuclear Agency ARMED FORCES RADIOBIOLOGY RESEARCH INSTITUTE...neutron radiation is less amenable to amelioration by chemical radioprotectants and more difficult to assess by means of physical dosimetry . These...neutron dosimetry and radiobiology we have witnessed in the past several years,could not have been possible without the sustained efforts of many

  13. The Importance of Dosimetry Standardization in Radiobiology

    PubMed Central

    Desrosiers, Marc; DeWerd, Larry; Deye, James; Lindsay, Patricia; Murphy, Mark K; Mitch, Michael; Macchiarini, Francesca; Stojadinovic, Strahinja; Stone, Helen

    2013-01-01

    Radiation dose is central to much of radiobiological research. Precision and accuracy of dose measurements and reporting of the measurement details should be sufficient to allow the work to be interpreted and repeated and to allow valid comparisons to be made, both in the same laboratory and by other laboratories. Despite this, a careful reading of published manuscripts suggests that measurement and reporting of radiation dosimetry and setup for radiobiology research is frequently inadequate, thus undermining the reliability and reproducibility of the findings. To address these problems and propose a course of action, the National Cancer Institute (NCI), the National Institute of Allergy and Infectious Diseases (NIAID), and the National Institute of Standards and Technology (NIST) brought together representatives of the radiobiology and radiation physics communities in a workshop in September, 2011. The workshop participants arrived at a number of specific recommendations as enumerated in this paper and they expressed the desirability of creating dosimetry standard operating procedures (SOPs) for cell culture and for small and large animal experiments. It was also felt that these SOPs would be most useful if they are made widely available through mechanism(s) such as the web, where they can provide guidance to both radiobiologists and radiation physicists, be cited in publications, and be updated as the field and needs evolve. Other broad areas covered were the need for continuing education through tutorials at national conferences, and for journals to establish standards for reporting dosimetry. This workshop did not address issues of dosimetry for studies involving radiation focused at the sub-cellular level, internally-administered radionuclides, biodosimetry based on biological markers of radiation exposure, or dose reconstruction for epidemiological studies. PMID:26401441

  14. Fifteen symposia on microdosimetry: implications for modern particle-beam cancer radiotherapy.

    PubMed

    Wambersie, A; Menzel, H; Gueulette, J; Pihet, P

    2015-09-01

    The objective of microdosimetry was, and still is, to identify physical descriptions of the initial physical processes of ionising radiation interacting with biological matter which correlate with observed radiobiological effects with a view to improve the understanding of radiobiological mechanisms and effects. The introduction of therapy with particles starting with fast neutrons followed by negative pions, protons and light ions necessitated the application of biological weighting factors for absorbed dose in order to account for differences of the relative biological effectiveness (RBE). Dedicated radiobiological experiments in therapy beams with mammalian cells and with laboratory animals provided sets of RBE values which are used to evaluate empirical 'clinical RBE values'. The combination of such experiments with microdosimetric measurements in identical conditions offered the possibility to establish semi-empirical relationships between microdosimetric parameters and results of RBE studies. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. SU-G-TeP3-11: Radiobiological-Cum-Dosimetric Quality Assurance of Complex Radiotherapy Plans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paudel, N; Narayanasamy, G; Zhang, X

    2016-06-15

    Purpose: Dosimetric gamma-analysis used for QA of complex radiotherapy plans tests the dosimetric equivalence of a delivered plan with the treatment planning system (TPS) optimized plan. It does not examine whether a dosimetric difference results in any radiobiological difference. This study introduces a method to test the radiobiological and dosimetric equivalence between a delivered and the TPS optimized plan. Methods: Six head and neck and seven lung cancer VMAT or IMRT plans optimized for patient treatment were calculated and delivered to an ArcCheck phantom. ArcCheck measured dose distributions were compared with the TPS calculated dose distributions using a 2-D gamma-analysis.more » Dose volume histograms (DVHs) for various patient structures were obtained by using measured data in 3DVH software and compared against the TPS calculated DVHs using 3-D gamma analysis. DVH data were used in the Poisson model to calculate tumor control probability (TCP) for the treatment targets and in the sigmoid dose response model to calculate normal tissue complication probability (NTCP) for the normal structures. Results: Two-D and three-D gamma passing rates among six H&N patient plans differed by 0 to 2.7% and among seven lung plans by 0.1 to 4.5%. Average ± SD TCPs based on measurement and TPS were 0.665±0.018 and 0.674±0.044 for H&N, and 0.791±0.027 and 0.733±0.031 for lung plans, respectively. Differences in NTCPs were usually negligible. The differences in dosimetric results, TCPs and NTCPs were insignificant. Conclusion: The 2-D and 3-D gamma-analysis based agreement between measured and planned dose distributions may indicate their dosimetric equivalence. Small and insignificant differences in TCPs and NTCPs based on measured and planned dose distributions indicate the radiobiological equivalence between the measured and optimized plans. However, patient plans showing larger differences between 2-D and 3-D gamma-analysis can help us make a more definite conclusion through our ongoing research with a larger number of patients.« less

  16. Progress on the accelerator based SPES-BNCT project at INFN Legnaro

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Esposito, J.; Colautti, P.; Pisent, A.

    2007-02-12

    In the framework of an advanced Exotic Ion Beam facility, named SPES (Study and Production of Exotic Species), that will allow a frontier program both in nuclear and interdisciplinary physics, an intense thermal neutron beam facility, devoted to perform Boron Neutron Capture Therapy (BNCT) experimental treatments on skin melanoma tumor, is currently under construction based on the SPES proton driver. A vast radiobiological investigation in vitro and in vivo has started with the new 10B carriers developed. Special microdosimetric detectors have been constructed to properly measure all the BNCT dose components and their qualities. Both microdosimetric and radiobiological measurements aremore » being performed at the new HYTHOR beam shaping assembly at the Enea-Casaccia TAPIRO reactor.« less

  17. Radiobiological effectiveness of laser accelerated electrons in comparison to electron beams from a conventional linear accelerator.

    PubMed

    Laschinsky, Lydia; Baumann, Michael; Beyreuther, Elke; Enghardt, Wolfgang; Kaluza, Malte; Karsch, Leonhard; Lessmann, Elisabeth; Naumburger, Doreen; Nicolai, Maria; Richter, Christian; Sauerbrey, Roland; Schlenvoigt, Hans-Peter; Pawelke, Jörg

    2012-01-01

    The notable progress in laser particle acceleration technology promises potential medical application in cancer therapy through compact and cost effective laser devices that are suitable for already existing clinics. Previously, consequences on the radiobiological response by laser driven particle beams characterised by an ultra high peak dose rate have to be investigated. Therefore, tumour and non-malignant cells were irradiated with pulsed laser accelerated electrons at the JETI facility for the comparison with continuous electrons of a conventional therapy LINAC. Dose response curves were measured for the biological endpoints clonogenic survival and residual DNA double strand breaks. The overall results show no significant differences in radiobiological response for in vitro cell experiments between laser accelerated pulsed and clinical used electron beams. These first systematic in vitro cell response studies with precise dosimetry to laser driven electron beams represent a first step toward the long term aim of the application of laser accelerated particles in radiotherapy.

  18. Radiobiological evaluation of the influence of dwell time modulation restriction in HIPO optimized HDR prostate brachytherapy implants.

    PubMed

    Mavroidis, Panayiotis; Katsilieri, Zaira; Kefala, Vasiliki; Milickovic, Natasa; Papanikolaou, Nikos; Karabis, Andreas; Zamboglou, Nikolaos; Baltas, Dimos

    2010-09-01

    One of the issues that a planner is often facing in HDR brachytherapy is the selective existence of high dose volumes around some few dominating dwell positions. If there is no information available about its necessity (e.g. location of a GTV), then it is reasonable to investigate whether this can be avoided. This effect can be eliminated by limiting the free modulation of the dwell times. HIPO, an inverse treatment plan optimization algorithm, offers this option. In treatment plan optimization there are various methods that try to regularize the variation of dose non-uniformity using purely dosimetric measures. However, although these methods can help in finding a good dose distribution they do not provide any information regarding the expected treatment outcome as described by radiobiology based indices. The quality of 12 clinical HDR brachytherapy implants for prostate utilizing HIPO and modulation restriction (MR) has been compared to alternative plans with HIPO and free modulation (without MR). All common dose-volume indices for the prostate and the organs at risk have been considered together with radiobiological measures. The clinical effectiveness of the different dose distributions was investigated by calculating the response probabilities of the tumors and organs-at-risk (OARs) involved in these prostate cancer cases. The radiobiological models used are the Poisson and the relative seriality models. Furthermore, the complication-free tumor control probability, P + and the biologically effective uniform dose ([Formula: see text]) were used for treatment plan evaluation and comparison. Our results demonstrate that HIPO with a modulation restriction value of 0.1-0.2 delivers high quality plans which are practically equivalent to those achieved with free modulation regarding the clinically used dosimetric indices. In the comparison, many of the dosimetric and radiobiological indices showed significantly different results. The modulation restricted clinical plans demonstrated a lower total dwell time by a mean of 1.4% that was proved to be statistically significant ( p = 0.002). The HIPO with MR treatment plans produced a higher P + by 0.5%, which stemmed from a better sparing of the OARs by 1.0%. Both the dosimetric and radiobiological comparison shows that the modulation restricted optimization gives on average similar results with the optimization without modulation restriction in the examined clinical cases. Concluding, based on our results, it appears that the applied dwell time regularization technique is expected to introduce a minor improvement in the effectiveness of the optimized HDR dose distributions.

  19. Radiobiological evaluation of the influence of dwell time modulation restriction in HIPO optimized HDR prostate brachytherapy implants

    PubMed Central

    Katsilieri, Zaira; Kefala, Vasiliki; Milickovic, Natasa; Papanikolaou, Nikos; Karabis, Andreas; Zamboglou, Nikolaos; Baltas, Dimos

    2010-01-01

    Purpose One of the issues that a planner is often facing in HDR brachytherapy is the selective existence of high dose volumes around some few dominating dwell positions. If there is no information available about its necessity (e.g. location of a GTV), then it is reasonable to investigate whether this can be avoided. This effect can be eliminated by limiting the free modulation of the dwell times. HIPO, an inverse treatment plan optimization algorithm, offers this option. In treatment plan optimization there are various methods that try to regularize the variation of dose non-uniformity using purely dosimetric measures. However, although these methods can help in finding a good dose distribution they do not provide any information regarding the expected treatment outcome as described by radiobiology based indices. Material and methods The quality of 12 clinical HDR brachytherapy implants for prostate utilizing HIPO and modulation restriction (MR) has been compared to alternative plans with HIPO and free modulation (without MR). All common dose-volume indices for the prostate and the organs at risk have been considered together with radiobiological measures. The clinical effectiveness of the different dose distributions was investigated by calculating the response probabilities of the tumors and organs-at-risk (OARs) involved in these prostate cancer cases. The radiobiological models used are the Poisson and the relative seriality models. Furthermore, the complication-free tumor control probability, P+ and the biologically effective uniform dose (D¯¯) were used for treatment plan evaluation and comparison. Results Our results demonstrate that HIPO with a modulation restriction value of 0.1-0.2 delivers high quality plans which are practically equivalent to those achieved with free modulation regarding the clinically used dosimetric indices. In the comparison, many of the dosimetric and radiobiological indices showed significantly different results. The modulation restricted clinical plans demonstrated a lower total dwell time by a mean of 1.4% that was proved to be statistically significant (p = 0.002). The HIPO with MR treatment plans produced a higher P+ by 0.5%, which stemmed from a better sparing of the OARs by 1.0%. Conclusions Both the dosimetric and radiobiological comparison shows that the modulation restricted optimization gives on average similar results with the optimization without modulation restriction in the examined clinical cases. Concluding, based on our results, it appears that the applied dwell time regularization technique is expected to introduce a minor improvement in the effectiveness of the optimized HDR dose distributions. PMID:27853473

  20. Novel Radiobiological Gamma Index for Evaluation of 3-Dimensional Predicted Dose Distribution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sumida, Iori, E-mail: sumida@radonc.med.osaka-u.ac.jp; Yamaguchi, Hajime; Kizaki, Hisao

    2015-07-15

    Purpose: To propose a gamma index-based dose evaluation index that integrates the radiobiological parameters of tumor control (TCP) and normal tissue complication probabilities (NTCP). Methods and Materials: Fifteen prostate and head and neck (H&N) cancer patients received intensity modulated radiation therapy. Before treatment, patient-specific quality assurance was conducted via beam-by-beam analysis, and beam-specific dose error distributions were generated. The predicted 3-dimensional (3D) dose distribution was calculated by back-projection of relative dose error distribution per beam. A 3D gamma analysis of different organs (prostate: clinical [CTV] and planned target volumes [PTV], rectum, bladder, femoral heads; H&N: gross tumor volume [GTV], CTV,more » spinal cord, brain stem, both parotids) was performed using predicted and planned dose distributions under 2%/2 mm tolerance and physical gamma passing rate was calculated. TCP and NTCP values were calculated for voxels with physical gamma indices (PGI) >1. We propose a new radiobiological gamma index (RGI) to quantify the radiobiological effects of TCP and NTCP and calculate radiobiological gamma passing rates. Results: The mean RGI gamma passing rates for prostate cases were significantly different compared with those of PGI (P<.03–.001). The mean RGI gamma passing rates for H&N cases (except for GTV) were significantly different compared with those of PGI (P<.001). Differences in gamma passing rates between PGI and RGI were due to dose differences between the planned and predicted dose distributions. Radiobiological gamma distribution was visualized to identify areas where the dose was radiobiologically important. Conclusions: RGI was proposed to integrate radiobiological effects into PGI. This index would assist physicians and medical physicists not only in physical evaluations of treatment delivery accuracy, but also in clinical evaluations of predicted dose distribution.« less

  1. Dosimetry in nuclear medicine therapy: radiobiology application and results.

    PubMed

    Strigari, L; Benassi, M; Chiesa, C; Cremonesi, M; Bodei, L; D'Andrea, M

    2011-04-01

    The linear quadratic model (LQM) has largely been used to assess the radiobiological damage to tissue by external beam fractionated radiotherapy and more recently has been extended to encompass a general continuous time varying dose rate protocol such as targeted radionuclide therapy (TRT). In this review, we provide the basic aspects of radiobiology, from a theoretical point of view, starting from the "four Rs" of radiobiology and introducing the biologically effective doses, which may be used to quantify the impact of a treatment on both tumors and normal tissues. We also present the main parameters required in the LQM, and illustrate the main models of tumor control probability and normal tissue complication probability and summarize the main dose-effect responses, reported in literature, which demonstrate the tentative link between targeted radiotherapy doses and those used in conventional radiotherapy. A better understanding of the radiobiology and mechanisms of action of TRT could contribute to describe the clinical data and guide the development of future compounds and the designing of prospective clinical trials.

  2. The significance of the choice of radiobiological (NTCP) models in treatment plan objective functions.

    PubMed

    Miller, J; Fuller, M; Vinod, S; Suchowerska, N; Holloway, L

    2009-06-01

    A Clinician's discrimination between radiation therapy treatment plans is traditionally a subjective process, based on experience and existing protocols. A more objective and quantitative approach to distinguish between treatment plans is to use radiobiological or dosimetric objective functions, based on radiobiological or dosimetric models. The efficacy of models is not well understood, nor is the correlation of the rank of plans resulting from the use of models compared to the traditional subjective approach. One such radiobiological model is the Normal Tissue Complication Probability (NTCP). Dosimetric models or indicators are more accepted in clinical practice. In this study, three radiobiological models, Lyman NTCP, critical volume NTCP and relative seriality NTCP, and three dosimetric models, Mean Lung Dose (MLD) and the Lung volumes irradiated at 10Gy (V10) and 20Gy (V20), were used to rank a series of treatment plans using, harm to normal (Lung) tissue as the objective criterion. None of the models considered in this study showed consistent correlation with the Radiation Oncologists plan ranking. If radiobiological or dosimetric models are to be used in objective functions for lung treatments, based on this study it is recommended that the Lyman NTCP model be used because it will provide most consistency with traditional clinician ranking.

  3. Grid Block Design Based on Monte Carlo Simulated Dosimetry, the Linear Quadratic and Hug–Kellerer Radiobiological Models

    PubMed Central

    Gholami, Somayeh; Nedaie, Hassan Ali; Longo, Francesco; Ay, Mohammad Reza; Dini, Sharifeh A.; Meigooni, Ali S.

    2017-01-01

    Purpose: The clinical efficacy of Grid therapy has been examined by several investigators. In this project, the hole diameter and hole spacing in Grid blocks were examined to determine the optimum parameters that give a therapeutic advantage. Methods: The evaluations were performed using Monte Carlo (MC) simulation and commonly used radiobiological models. The Geant4 MC code was used to simulate the dose distributions for 25 different Grid blocks with different hole diameters and center-to-center spacing. The therapeutic parameters of these blocks, namely, the therapeutic ratio (TR) and geometrical sparing factor (GSF) were calculated using two different radiobiological models, including the linear quadratic and Hug–Kellerer models. In addition, the ratio of the open to blocked area (ROTBA) is also used as a geometrical parameter for each block design. Comparisons of the TR, GSF, and ROTBA for all of the blocks were used to derive the parameters for an optimum Grid block with the maximum TR, minimum GSF, and optimal ROTBA. A sample of the optimum Grid block was fabricated at our institution. Dosimetric characteristics of this Grid block were measured using an ionization chamber in water phantom, Gafchromic film, and thermoluminescent dosimeters in Solid Water™ phantom materials. Results: The results of these investigations indicated that Grid blocks with hole diameters between 1.00 and 1.25 cm and spacing of 1.7 or 1.8 cm have optimal therapeutic parameters (TR > 1.3 and GSF~0.90). The measured dosimetric characteristics of the optimum Grid blocks including dose profiles, percentage depth dose, dose output factor (cGy/MU), and valley-to-peak ratio were in good agreement (±5%) with the simulated data. Conclusion: In summary, using MC-based dosimetry, two radiobiological models, and previously published clinical data, we have introduced a method to design a Grid block with optimum therapeutic response. The simulated data were reproduced by experimental data. PMID:29296035

  4. An image-guided precision proton radiation platform for preclinical in vivo research

    NASA Astrophysics Data System (ADS)

    Ford, E.; Emery, R.; Huff, D.; Narayanan, M.; Schwartz, J.; Cao, N.; Meyer, J.; Rengan, R.; Zeng, J.; Sandison, G.; Laramore, G.; Mayr, N.

    2017-01-01

    There are many unknowns in the radiobiology of proton beams and other particle beams. We describe the development and testing of an image-guided low-energy proton system optimized for radiobiological research applications. A 50 MeV proton beam from an existing cyclotron was modified to produce collimated beams (as small as 2 mm in diameter). Ionization chamber and radiochromic film measurements were performed and benchmarked with Monte Carlo simulations (TOPAS). The proton beam was aligned with a commercially-available CT image-guided x-ray irradiator device (SARRP, Xstrahl Inc.). To examine the alternative possibility of adapting a clinical proton therapy system, we performed Monte Carlo simulations of a range-shifted 100 MeV clinical beam. The proton beam exhibits a pristine Bragg Peak at a depth of 21 mm in water with a dose rate of 8.4 Gy min-1 (3 mm depth). The energy of the incident beam can be modulated to lower energies while preserving the Bragg peak. The LET was: 2.0 keV µm-1 (water surface), 16 keV µm-1 (Bragg peak), 27 keV µm-1 (10% peak dose). Alignment of the proton beam with the SARRP system isocenter was measured at 0.24 mm agreement. The width of the beam changes very little with depth. Monte Carlo-based calculations of dose using the CT image data set as input demonstrate in vivo use. Monte Carlo simulations of the modulated 100 MeV clinical proton beam show a significantly reduced Bragg peak. We demonstrate the feasibility of a proton beam integrated with a commercial x-ray image-guidance system for preclinical in vivo studies. To our knowledge this is the first description of an experimental image-guided proton beam for preclinical radiobiology research. It will enable in vivo investigations of radiobiological effects in proton beams.

  5. Cell irradiation setup and dosimetry for radiobiological studies at ELBE

    NASA Astrophysics Data System (ADS)

    Zeil, K.; Beyreuther, E.; Lessmann, E.; Wagner, W.; Pawelke, J.

    2009-07-01

    The radiation source ELBE delivers different types of secondary radiation, which is used for cell irradiation studies in radiobiological research. Thereby an important issue is the determination of the biological effectiveness of photon radiation as a function of photon energy by using low-energetic, monochromatic channeling radiation (10-100 keV) and high-energetic bremsstrahlung (up to 40 MV). Radiobiological studies at the research facility ELBE demand special technical and dosimetric prerequisites. Therefore, a cell irradiation system (CIS) has been designed, constructed and installed at the beam line. The CIS allows automatic irradiation of a larger cell sample number and the compensation of spatial inhomogeneity of the dose distribution within the beam spot. The recently introduced GafChromic ® EBT radiochromic film model has been used to verify the cell irradiation dose deposition achieving a dose uncertainty of <5%. Both, the installed cell irradiation system and the developed dosimetric procedure based on the use of the EBT film have been experimentally tested at ELBE. The biological effectiveness of 34 MV bremsstrahlung with respect to 200 kV X-rays from a conventional X-ray tube has been determined. An RBE value of 0.75 has been measured in good agreement with literature.

  6. "Radiobiology of Proton Therapy": Results of an international expert workshop.

    PubMed

    Lühr, Armin; von Neubeck, Cläre; Pawelke, Jörg; Seidlitz, Annekatrin; Peitzsch, Claudia; Bentzen, Søren M; Bortfeld, Thomas; Debus, Jürgen; Deutsch, Eric; Langendijk, Johannes A; Loeffler, Jay S; Mohan, Radhe; Scholz, Michael; Sørensen, Brita S; Weber, Damien C; Baumann, Michael; Krause, Mechthild

    2018-05-31

    The physical properties of proton beams offer the potential to reduce toxicity in tumor-adjacent normal tissues. Toward this end, the number of proton radiotherapy facilities has steeply increased over the last 10-15 years to currently around 70 operational centers worldwide. However, taking full advantage of the opportunities offered by proton radiation for clinical radiotherapy requires a better understanding of the radiobiological effects of protons alone or combined with drugs or immunotherapy on normal tissues and tumors. This report summarizes the main results of the international expert workshop "Radiobiology of Proton Therapy" that was held in November 2016 in Dresden. It addresses the major topics (1) relative biological effectiveness (RBE) in proton beam therapy, (2) interaction of proton radiobiology with radiation physics in current treatment planning, (3) biological effects in proton therapy combined with systemic treatments, and (4) testing biological effects of protons in clinical trials. Finally, important research avenues for improvement of proton radiotherapy based on radiobiological knowledge are identified. The clinical distribution of radiobiological effectiveness of protons alone or in combination with systemic chemo- or immunotherapies as well as patient stratification based on biomarker expressions are key to reach the full potential of proton beam therapy. Dedicated preclinical experiments, innovative clinical trial designs, and large high-quality data repositories will be most important to achieve this goal. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Monte Carlo role in radiobiological modelling of radiotherapy outcomes

    NASA Astrophysics Data System (ADS)

    El Naqa, Issam; Pater, Piotr; Seuntjens, Jan

    2012-06-01

    Radiobiological models are essential components of modern radiotherapy. They are increasingly applied to optimize and evaluate the quality of different treatment planning modalities. They are frequently used in designing new radiotherapy clinical trials by estimating the expected therapeutic ratio of new protocols. In radiobiology, the therapeutic ratio is estimated from the expected gain in tumour control probability (TCP) to the risk of normal tissue complication probability (NTCP). However, estimates of TCP/NTCP are currently based on the deterministic and simplistic linear-quadratic formalism with limited prediction power when applied prospectively. Given the complex and stochastic nature of the physical, chemical and biological interactions associated with spatial and temporal radiation induced effects in living tissues, it is conjectured that methods based on Monte Carlo (MC) analysis may provide better estimates of TCP/NTCP for radiotherapy treatment planning and trial design. Indeed, over the past few decades, methods based on MC have demonstrated superior performance for accurate simulation of radiation transport, tumour growth and particle track structures; however, successful application of modelling radiobiological response and outcomes in radiotherapy is still hampered with several challenges. In this review, we provide an overview of some of the main techniques used in radiobiological modelling for radiotherapy, with focus on the MC role as a promising computational vehicle. We highlight the current challenges, issues and future potentials of the MC approach towards a comprehensive systems-based framework in radiobiological modelling for radiotherapy.

  8. Radiobiological research at JINR's accelerators

    NASA Astrophysics Data System (ADS)

    Krasavin, E. A.

    2016-04-01

    The half-a-century development of radiobiological studies at the Joint Institute for Nuclear Research (JINR) is reviewed on a stage-by-stage basis. With the use of the institute's accelerators, some key aspects of radiation biology have been settled, including the relative biological effectiveness (RBE) of various types of ionizing radiation with different physical characteristics; radiation-induced mutagenesis mechanisms, and the formation and repair of genetic structure damage. Practical space radiobiology problems that can be solved using high-energy charged particles are discussed.

  9. Development of a compact laser-produced plasma soft X-ray source for radiobiology experiments

    NASA Astrophysics Data System (ADS)

    Adjei, Daniel; Ayele, Mesfin Getachew; Wachulak, Przemyslaw; Bartnik, Andrzej; Wegrzynski, Łukasz; Fiedorowicz, Henryk; Vyšín, Luděk; Wiechec, Anna; Lekki, Janusz; Kwiatek, Wojciech M.; Pina, Ladislav; Davídková, Marie; Juha, Libor

    2015-12-01

    A desk-top laser-produced plasma (LPP) source of soft X-rays (SXR) has been developed for radiobiology research. The source is based on a double-stream gas puff target, irradiated with the focused beam of a commercial Nd:YAG laser. The source has been optimized to get a maximum photon emission from LPP in the X-ray "water window" spectral wavelength range from 2.3 nm (i.e., an absorption edge of oxygen) to 4.4 nm (i.e., an absorption edge of carbon) (280-540 eV in photon energy units) by using argon gas-puff target and spectral filtering by free-standing thin foils. The present source delivers nanosecond pulses of soft X-rays at a fluence of about 4.2 × 103 photons/μm2/pulse on a sample placed inside the vacuum chamber. In this paper, the source design, radiation output characterization measurements and initial irradiation experiments are described. The source can be useful in addressing observations related to biomolecular, cellular and organisms' sensitivity to pulsed radiation in the "water window", where carbon atoms absorb X-rays more strongly than the oxygen, mostly present in water. The combination of the SXR source and the radiobiology irradiation layout, reported in this article, make possible a systematic investigation of relationships between direct and indirect action of ionizing radiation, an increase of a local dose in carbon-rich compartments of the cell (e.g., lipid membranes), an experimental estimation of a particular role of the Auger effect (in particular in carbon atoms) in the damage to biological systems, and the study of ionization/excitation-density (LET - Linear Energy Transfer) and dose-rate effects in radiobiology.

  10. Impact of the NTCP modeling on medical decision to select eligible patient for proton therapy: the usefulness of EUD as an indicator to rank modern photon vs proton treatment plans.

    PubMed

    Chaikh, Abdulhamid; Calugaru, Valentin; Bondiau, Pierre-Yves; Thariat, Juliette; Balosso, Jacques

    2018-06-07

    The aim of this study is to evaluate the impact of normal tissue complication probability (NTCP)-based radiobiological models on the estimated risk for late radiation lung damages. The second goal is to propose a medical decision-making approach to select the eligible patient for particle therapy. 14 pediatric patients undergoing cranio-spinal irradiation were evaluated. For each patient, two treatment plans were generated using photon and proton therapy with the same dose prescriptions. Late radiation damage to lung was estimated using three NTCP concepts: the Lyman-Kutcher-Burman, the equivalent uniform dose (EUD) and the mean lung dose according to the quantitative analysis of normal tissue effects in the clinic QUANTEC review. Wilcoxon paired test was used to calculate p-value. Proton therapy achieved lower lung EUD (Gy). The average NTCP values were significantly lower with proton plans, p < 0.05, using the three NTCP concepts. However, applying the same TD 50/5 using radiobiological models to compare NTCP from proton and photon therapy, the ΔNTCP was not a convincing method to measure the potential benefit of proton therapy. Late radiation pneumonitis estimated from the mean lung dose model correlated with QUANTEC data better. treatment effectiveness assessed on NTCP reduction depends on radiobiological predictions and parameters used as inputs for in silico evaluation. Since estimates of absolute NTCP values from LKB and GN models are imprecise due to EUD ≪ TD 50/5 , a reduction of the EUD value with proton plans would better predict a reduction of dose/toxicity. The EUD concept appears as a robust radiobiological surrogate of the dose distribution to select the optimal patient's plan.

  11. Radiotherapy of meningioma: a treatment in need of radiobiological research.

    PubMed

    Pinzi, Valentina; Bisogno, Ilaria; Prada, Francesco; Ciusani, Emilio; Fariselli, Laura

    2018-05-18

    Meningiomas account for one third of primary intracranial tumors, nevertheless information on meningioma cell lines and in vivo models is scant. Although radiotherapy is one of the most relevant therapeutic options for the treatment patients with meningioma, radiobiological research to understand tumor responses to this treatment is far from being thoroughly understood. The aim of this report is to provide a comprehensive picture of the current literature on this field, so as to foster s research in this regard. We carried out a review of meningioma radiobiology based on a peer-reviewed PubMed search. As a result of our study, we can confirm that the main limitation of radiobiological research into meningioma is the paucity of robust in vitro and in vivo models. Alternative approaches to overcome the already identified problems, and to allow better understanding of the entire histopathological spectrum of meningiomas have been explored. A radiobiological perspective of meningioma may help to improve clinical results both in terms of tumour control and healthy tissue sparing. Although we are far from drawing any conclusions, this review can lead researchers to identify some cues for future areas of study.

  12. Radiobiological characterization of post-lumpectomy focal brachytherapy with lipid nanoparticle-carried radionuclides

    NASA Astrophysics Data System (ADS)

    Hrycushko, Brian A.; Gutierrez, Alonso N.; Goins, Beth; Yan, Weiqiang; Phillips, William T.; Otto, Pamela M.; Bao, Ande

    2011-02-01

    Post-operative radiotherapy has commonly been used for early stage breast cancer to treat residual disease. The primary objective of this work was to characterize, through dosimetric and radiobiological modeling, a novel focal brachytherapy technique which uses direct intracavitary infusion of β-emitting radionuclides (186Re/188Re) carried by lipid nanoparticles (liposomes). Absorbed dose calculations were performed for a spherical lumpectomy cavity with a uniformly injected activity distribution using a dose point kernel convolution technique. Radiobiological indices were used to relate predicted therapy outcome and normal tissue complication of this technique with equivalent external beam radiotherapy treatment regimens. Modeled stromal damage was used as a measure of the inhibition of the stimulatory effect on tumor growth driven by the wound healing response. A sample treatment plan delivering 50 Gy at a therapeutic range of 2.0 mm for 186Re-liposomes and 5.0 mm for 188Re-liposomes takes advantage of the dose delivery characteristics of the β-emissions, providing significant EUD (58.2 Gy and 72.5 Gy for 186Re and 188Re, respectively) with a minimal NTCP (0.046%) of the healthy ipsilateral breast. Modeling of kidney BED and ipsilateral breast NTCP showed that large injected activity concentrations of both radionuclides could be safely administered without significant complications.

  13. Scientific experiments on the flight of the 1979 biological satellite, draft plan

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The various physiological, biological, radiobiological, and radiation physics experiments to be conducted onboard the 1979 biological satellite are described. These experiments deal with the effects of space flight on living organisms, measurement of radiation, and possible methods of shielding spacecraft against such radiation.

  14. Overview of research and therapy facilities for radiobiological experimental work in particle therapy. Report from the European Particle Therapy Network radiobiology group.

    PubMed

    Dosanjh, Manjit; Jones, Bleddyn; Pawelke, Jörg; Pruschy, Martin; Sørensen, Brita Singers

    2018-04-24

    Particle therapy (PT) as cancer treatment, using protons or heavier ions, can provide a more favorable dose distribution compared to X-rays. While the physical characteristics of particle radiation have been the aim of intense research, less focus has been placed on the actual biological responses arising from particle irradiation. One of the biggest challenges for proton radiobiology is the RBE, with an increasing concern that the clinically-applied generic RBE-value of 1.1 is an approximation, as RBE is a complex quantity, depending on both biological and physical parameters, such as dose, LET, cellular and tissue radiobiological characteristics, as well as the endpoints being studied. Most of the available RBE data derive from in vitro experiments, with very limited in vivo data available, especially in late-reacting tissues, which provide the main constraints and influence the quality of life endpoints in radiotherapy. There is a need for systematic, large-scale studies to thoroughly establish the biology of particle radiation in a number of different experimental models in order to refine biophysical mathematical models that can potentially be used to guide PT. The overall objective of the European Particle Therapy Network (EPTN) WP6 is to form a network of research and therapy facilities in order to coordinate and standardize the radiobiological experiments, to obtain more accurate predictive parameters than in the past. Coordinated research is required in order to obtain the most appropriate experimental data. The aim in this paper is to describe the available radiobiology infrastructure of the centers involved in EPTN WP6. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. The European Radiobiology Archives (ERA)--content, structure and use illustrated by an example.

    PubMed

    Gerber, G B; Wick, R R; Kellerer, A M; Hopewell, J W; Di Majo, V; Dudoignon, N; Gössner, W; Stather, J

    2006-01-01

    The European Radiobiology Archives (ERA), supported by the European Commission and the European Late Effect Project Group (EULEP), together with the US National Radiobiology Archives (NRA) and the Japanese Radiobiology Archives (JRA) have collected all information still available on long-term animal experiments, including some selected human studies. The archives consist of a database in Microsoft Access, a website, databases of references and information on the use of the database. At present, the archives contain a description of the exposure conditions, animal strains, etc. from approximately 350,000 individuals; data on survival and pathology are available from approximately 200,000 individuals. Care has been taken to render pathological diagnoses compatible among different studies and to allow the lumping of pathological diagnoses into more general classes. 'Forms' in Access with an underlying computer code facilitate the use of the database. This paper describes the structure and content of the archives and illustrates an example for a possible analysis of such data.

  16. Tumour and normal tissue radiobiology in mouse models: how close are mice to mini-humans?

    PubMed

    Koontz, Bridget F; Verhaegen, Frank; De Ruysscher, Dirk

    2017-01-01

    Animal modelling is essential to the study of radiobiology and the advancement of clinical radiation oncology by providing preclinical data. Mouse models in particular have been highly utilized in the study of both tumour and normal tissue radiobiology because of their cost effectiveness and versatility. Technology has significantly advanced in preclinical radiation techniques to allow highly conformal image-guided irradiation of small animals in an effort to mimic human treatment capabilities. However, the biological and physical limitations of animal modelling should be recognized and considered when interpreting preclinical radiotherapy (RT) studies. Murine tumour and normal tissue radioresponse has been shown to vary from human cellular and molecular pathways. Small animal irradiation techniques utilize different anatomical boundaries and may have different physical properties than human RT. This review addresses the difference between the human condition and mouse models and discusses possible strategies for future refinement of murine models of cancer and radiation for the benefit of both basic radiobiology and clinical translation.

  17. Tumour and normal tissue radiobiology in mouse models: how close are mice to mini-humans?

    PubMed Central

    Verhaegen, Frank; De Ruysscher, Dirk

    2017-01-01

    Animal modelling is essential to the study of radiobiology and the advancement of clinical radiation oncology by providing preclinical data. Mouse models in particular have been highly utilized in the study of both tumour and normal tissue radiobiology because of their cost effectiveness and versatility. Technology has significantly advanced in preclinical radiation techniques to allow highly conformal image-guided irradiation of small animals in an effort to mimic human treatment capabilities. However, the biological and physical limitations of animal modelling should be recognized and considered when interpreting preclinical radiotherapy (RT) studies. Murine tumour and normal tissue radioresponse has been shown to vary from human cellular and molecular pathways. Small animal irradiation techniques utilize different anatomical boundaries and may have different physical properties than human RT. This review addresses the difference between the human condition and mouse models and discusses possible strategies for future refinement of murine models of cancer and radiation for the benefit of both basic radiobiology and clinical translation. PMID:27612010

  18. Radiobiological modeling of two stereotactic body radiotherapy schedules in patients with stage I peripheral non-small cell lung cancer.

    PubMed

    Huang, Bao-Tian; Lin, Zhu; Lin, Pei-Xian; Lu, Jia-Yang; Chen, Chuang-Zhen

    2016-06-28

    This study aims to compare the radiobiological response of two stereotactic body radiotherapy (SBRT) schedules for patients with stage I peripheral non-small cell lung cancer (NSCLC) using radiobiological modeling methods. Volumetric modulated arc therapy (VMAT)-based SBRT plans were designed using two dose schedules of 1 × 34 Gy (34 Gy in 1 fraction) and 4 × 12 Gy (48 Gy in 4 fractions) for 19 patients diagnosed with primary stage I NSCLC. Dose to the gross target volume (GTV), planning target volume (PTV), lung and chest wall (CW) were converted to biologically equivalent dose in 2 Gy fraction (EQD2) for comparison. Five different radiobiological models were employed to predict the tumor control probability (TCP) value. Three additional models were utilized to estimate the normal tissue complication probability (NTCP) value for the lung and the modified equivalent uniform dose (mEUD) value to the CW. Our result indicates that the 1 × 34 Gy dose schedule provided a higher EQD2 dose to the tumor, lung and CW. Radiobiological modeling revealed that the TCP value for the tumor, NTCP value for the lung and mEUD value for the CW were 7.4% (in absolute value), 7.2% (in absolute value) and 71.8% (in relative value) higher on average, respectively, using the 1 × 34 Gy dose schedule.

  19. A modular approach for assessing the effect of radiation environments on man in operational systems. The radiobiological vulnerability of man during task performance

    NASA Technical Reports Server (NTRS)

    Ewing, D. E.

    1972-01-01

    A modular approach for assessing the affects of radiation environments on man in operational systems has been developed. The feasibility of the model has been proved and the practicality has been assessed. It has been applied to one operational system to date and information obtained has been submitted to systems analysts and mission planners for the assessment of man's vulnerability and impact on systems survivability. In addition, the model has been developed so that the radiobiological data can be input to a sophisticated man-machine interface model to properly relate the radiobiological stress with other mission stresses including the effects of a degraded system.

  20. Effects of radiobiological uncertainty on shield design for a 60-day lunar mission

    NASA Technical Reports Server (NTRS)

    Wilson, John W.; Nealy, John E.; Schimmerling, Walter

    1993-01-01

    Some consequences of uncertainties in radiobiological risk due to galactic cosmic ray exposure are analyzed to determine their effect on engineering designs for a first lunar outpost - a 60-day mission. Quantitative estimates of shield mass requirements as a function of a radiobiological uncertainty factor are given for a simplified vehicle structure. The additional shield mass required for compensation is calculated as a function of the uncertainty in galactic cosmic ray exposure, and this mass is found to be as large as a factor of 3 for a lunar transfer vehicle. The additional cost resulting from this mass is also calculated. These cost estimates are then used to exemplify the cost-effectiveness of research.

  1. Radiobiological compensation: A case study of uterine cervix cancer with concurrent chemotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Herrera, Higmar; Yanez, Elvia; Lopez, Jesus

    2012-10-23

    The case of a patient diagnosed with uterine cervix cancer is presented as an example of the clinical application of the radiobiological compensation method implemented at Centro Estatal de Cancerologia de Durango. Radiotherapy treatment was initially modified to compensate for the chemotherapy component and, as medical complications arose during treatment delivery resulting in an 18 days gap, new compensation followed. All physical and radiobiological assumptions to calculate the Biologically Effective Dose in the external beam and brachytherapy parts of the treatment are presented. Good local control of the tumor was achieved, the theoretical tolerance limits for the organs at riskmore » were not surpassed and the patient manifested no extensive morbidity.« less

  2. Radiobiological compensation: A case study of uterine cervix cancer with concurrent chemotherapy

    NASA Astrophysics Data System (ADS)

    Herrera, Higmar; Yañez, Elvia; López, Jesús

    2012-10-01

    The case of a patient diagnosed with uterine cervix cancer is presented as an example of the clinical application of the radiobiological compensation method implemented at Centro Estatal de Cancerología de Durango. Radiotherapy treatment was initially modified to compensate for the chemotherapy component and, as medical complications arose during treatment delivery resulting in an 18 days gap, new compensation followed. All physical and radiobiological assumptions to calculate the Biologically Effective Dose in the external beam and brachytherapy parts of the treatment are presented. Good local control of the tumor was achieved, the theoretical tolerance limits for the organs at risk were not surpassed and the patient manifested no extensive morbidity.

  3. Practical Radiobiology for Proton Therapy Planning

    NASA Astrophysics Data System (ADS)

    Jones, Bleddyn

    2017-12-01

    Practical Radiobiology for Proton Therapy Planning covers the principles, advantages and potential pitfalls that occur in proton therapy, especially its radiobiological modelling applications. This book is intended to educate, inform and to stimulate further research questions. Additionally, it will help proton therapy centres when designing new treatments or when unintended errors or delays occur. The clear descriptions of useful equations for high LET particle beam applications, worked examples of many important clinical situations, and discussion of how proton therapy may be optimized are all important features of the text. This important book blends the relevant physics, biology and medical aspects of this multidisciplinary subject. Part of Series in Physics and Engineering in Medicine and Biology.

  4. Use of the NASA Space Radiation Laboratory at Brookhaven National Laboratory to Conduct Charged Particle Radiobiology Studies Relevant to Ion Therapy

    PubMed Central

    Held, Kathryn D.; Blakely, Eleanor A.; Story, Michael D.; Lowenstein, Derek I.

    2016-01-01

    Although clinical studies with carbon ions have been conducted successfully in Japan and Europe, the limited radiobiological information about charged particles that are heavier than protons remains a significant impediment to exploiting the full potential of particle therapy. There is growing interest in the U.S. to build a cancer treatment facility that utilizes charged particles heavier than protons. Therefore, it is essential that additional radiobiological knowledge be obtained using state-of-the-art technologies and biological models and end points relevant to clinical outcome. Currently, most such ion radiotherapy-related research is being conducted outside the U.S. This article addresses the substantial contributions to that research that are possible at the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory (BNL), which is the only facility in the U.S. at this time where heavy-ion radiobiology research with the ion species and energies of interest for therapy can be done. Here, we briefly discuss the relevant facilities at NSRL and how selected charged particle biology research gaps could be addressed using those facilities. PMID:27195609

  5. Use of the NASA Space Radiation Laboratory at Brookhaven National Laboratory to Conduct Charged Particle Radiobiology Studies Relevant to Ion Therapy.

    PubMed

    Held, Kathryn D; Blakely, Eleanor A; Story, Michael D; Lowenstein, Derek I

    2016-06-01

    Although clinical studies with carbon ions have been conducted successfully in Japan and Europe, the limited radiobiological information about charged particles that are heavier than protons remains a significant impediment to exploiting the full potential of particle therapy. There is growing interest in the U.S. to build a cancer treatment facility that utilizes charged particles heavier than protons. Therefore, it is essential that additional radiobiological knowledge be obtained using state-of-the-art technologies and biological models and end points relevant to clinical outcome. Currently, most such ion radiotherapy-related research is being conducted outside the U.S. This article addresses the substantial contributions to that research that are possible at the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory (BNL), which is the only facility in the U.S. at this time where heavy-ion radiobiology research with the ion species and energies of interest for therapy can be done. Here, we briefly discuss the relevant facilities at NSRL and how selected charged particle biology research gaps could be addressed using those facilities.

  6. MO-D-BRD-03: Radiobiology and Commissioning of Electronic Brachytherapy for IORT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, J.

    2015-06-15

    Electronic brachytherapy (eBT) has seen an insurgence of manufacturers entering the US market for use in radiation therapy. In addition to the established interstitial, intraluminary, and intracavitary applications of eBT, many centers are now using eBT to treat skin lesions. It is important for medical physicists working with electronic brachytherapy sources to understand the basic physics principles of the sources themselves as well as the variety of applications for which they are being used. The calibration of the sources is different from vendor to vendor and the traceability of calibrations has evolved as new sources came to market. In 2014,more » a new air-kerma based standard was introduced by the National Institute of Standards and Technology (NIST) to measure the output of an eBT source. Eventually commercial treatment planning systems should accommodate this new standard and provide NIST traceability to the end user. The calibration and commissioning of an eBT system is unique to its application and typically entails a list of procedural recommendations by the manufacturer. Commissioning measurements are performed using a variety of methods, some of which are modifications of existing AAPM Task Group protocols. A medical physicist should be familiar with the different AAPM Task Group recommendations for applicability to eBT and how to properly adapt them to their needs. In addition to the physical characteristics of an eBT source, the photon energy is substantially lower than from HDR Ir-192 sources. Consequently, tissue-specific dosimetry and radiobiological considerations are necessary when comparing these brachytherapy modalities and when making clinical decisions as a radiation therapy team. In this session, the physical characteristics and calibration methodologies of eBt sources will be presented as well as radiobiology considerations and other important clinical considerations. Learning Objectives: To understand the basic principles of electronic brachytherapy and the various applications for which it is being used. To understand the physics of the calibration and commissioning for electronic brachytherapy sources To understand the unique radiobiology and clinical implementation of electronic brachytherapy systems for skin and IORT techniques Xoft, Inc. contributed funding toward development of the NIST electronic brachytherapy facility (Michael Mitch).The University of Wisconsin (Wesley Culberson) has received research support funding from Xoft, Inc. Zoubir Ouhib has received partial funding from Elekta Esteya.« less

  7. Apoptosis, energy metabolism, and fraction of radiobiologically hypoxic cells: a study of human melanoma multicellular spheroids.

    PubMed

    Rofstad, E K; Eide, K; Skøyum, R; Hystad, M E; Lyng, H

    1996-09-01

    The magnitude of the fraction of radiobiologically hypoxic cells in tumours is generally believed to reflect the efficiency of the vascular network. Theoretical studies have suggested that the hypoxic fraction might also be influenced by biological properties of the tumour cells. Quantitative experimental results of cell energy metabolism, hypoxia- induced apoptosis, and radiobiological hypoxia are reported here. Human melanoma multicellular spheroids (BEX-c and WIX-c) were used as tumour models to avoid confounding effects of the vascular network. Radiobiological studies showed that the fractions of hypoxic cells in 1000-microM spheroids were 32 +/- 12% (BEX-c) and 2.5 +/- 1.1% (WIX-c). The spheroid hypoxic volume fractions (28 +/- 6% (BEX-c) and 1.4 +/- 7% (WIX-c)), calculated from the rate of oxygen consumption per cell, the cell packing density, and the thickness of the viable rim, were similar to the fractions of radiobiologically hypoxic cells. Large differences between tumours in fraction of hypoxic cells are therefore not necessarily a result of differences in the efficiency of the vascular network. Studies of monolayer cell cultures, performed to identify the biological properties of the BEX-c and WIX-c cells leading to this large difference in fraction of hypoxic cells, gave the following results: (1) WIX-c showed lower cell surviving fractions after exposure to hypoxia than BEX-c, (2) WIX-c showed higher glucose uptake and lactate release rates than BEX-c both under aerobic and hypoxic conditions, and (3) hypoxia induced apoptosis in WIX-c but not in BEX-c. These observations suggested that the difference between BEX-c and WIX-c spheroids in fraction of hypoxic cells resulted partly from differences in cell energy metabolism and partly from a difference in capacity to retain viability under hypoxic stress. The induction of apoptosis by hypoxia was identified as a phenomenon which has an important influence on the magnitude of the fraction of radiobiologically hypoxic cells in multicellular spheroids.

  8. SU-F-T-03: Radiobiological Evaluation of a Directional Brachytherapy Device Surgically Implanted Following EBRT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rivard, MJ; Emrich, JG; Poli, J

    2016-06-15

    Purpose: Preceding surgical implantation following external-beam radiotherapy (EBRT) delivery, a radiobiological evaluation was performed for a new LDR Pd-103 directional brachytherapy device (CivaSheet). As this was the first case with the device used in combination with EBRT, there was concern to determine the appropriate prescription dose. Methods: The radiobiological model of Dale (1985, 1989) was used for a permanent LDR implant including radioactive decay. The biological effective dose (BED) was converted to the equivalent dose in 2 Gy fractions (EQD2) for comparison with EBRT prescription expectations. Given IMRT delivery of 50.4 Gy, an LDR brachytherapy dose of approximately 15–20 Gymore » EQD2 was desired. To be specific to the treatment site (leiomyosarcoma T2bN0M0, grade 2 with R1 surgical margin), the radiobiological model required several radiobiological parameters with values taken from the literature. A sensitivity analysis was performed to determine their relative importance on the calculated BED and subsequent EQD2. The Pd-103 decay constant (λ=0.0017 h{sup −1}) was also used. DVHs were prepared for pre- and post-surgical geometries to glean the possible and realized implant geometric configuration. DVHs prepared in VariSeed9 were converted to BEDVHs and subsequently EQD2 values for each volume-element. Results: For a physical dose of 28 Gy to a 0.5 cm depth, BED=21.7 Gy and EQD2=17.6 Gy, which was near the center of the desired EQD2 range. Tumor bed (CTV=4 cm{sup 3}) coverage was 99.2% with 48 sources implanted. In order of decreasing importance from the sensitivity analysis, the radiobiological parameters were α=0.25 Gy{sup −1}, T{sub POT}=23 days, α/β=8.6 Gy, and T=1.5 h. Percentage variations in these values produced EQD2 variations of 40%, 20%, 18%, and 1%, respectively. Conclusion: This radiobiological evaluation indicated that prescription dose may be determined for comparison with the desired EQD2, and that radiobiologicalparameter uncertainties produce smaller EQD2 differences than had physical dose been simply added to EBRT dose. Research support provided in part by CivaTech Oncology, Inc. for Dr. Rivard.« less

  9. Radiological and Environmental Research Division, Center for Human Radiobiology. Annual report, July 1980-June 1981. [Lead abstract

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1982-03-01

    Separate abstracts were prepared for the 22 papers of this annual report of the Center for Human Radiobiology. Abstracts were not written for 2 appendices which contain data on the exposure and radium-induced malignancies of 2259 persons whose radium content has been determined at least once. (KRM)

  10. Changing paradigms in radiobiology.

    PubMed

    Mothersill, Carmel; Seymour, Colin

    2012-01-01

    The last 25 years have seen a major shift in emphasis in the field of radiobiology from a DNA-centric view of how radiation damage occurs to a much more biological view that appreciates the importance of macro-and micro-environments, hierarchical organization, underlying genetics, evolution, adaptation and signaling at all levels from atoms to ecosystems. The new view incorporates concepts of hormesis, nonlinear systems, bioenergy field theory, uncertainty and homeodynamics. While the mechanisms underlying these effects and responses are still far from clear, it is very apparent that their implications are much wider than the field of radiobiology. This reflection discusses the changing views and considers how they are influencing thought in environmental and medical science and systems biology. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Trends, determinants and inequities of 4+ ANC utilisation in Bangladesh.

    PubMed

    Rahman, Aminur; Nisha, Monjura Khatun; Begum, Tahmina; Ahmed, Sayem; Alam, Nurul; Anwar, Iqbal

    2017-01-13

    The objectives of this study are to document the trend on utilisation of four or more (4 + ) antenatal care (ANC) over the last 22 years period and to explore the determinants and inequity of 4 + ANC utilisation as reported by the last two Bangladesh Demographic and Health surveys (BDHS) (2011 and 2014). The data related to ANC have been extracted from the BDHS data set which is available online as an open source. STATA 13 software was used for organising and analysing the data. The outcome variable considered for this study was utilisation of 4 + ANC. Trends of 4 + ANC were measured in percentage and predictors for 4 + ANC were measured through bivariate and multivariable analysis. The concentration index was estimated for assessing inequity in 4 + ANC utilisation. Utilisation of 4 + ANC has increased by about 26% between the year 1994 and 2014. Higher level of education, residing in urban region and richest wealth quintile were found to be significant predictors. The utilisation of 4 + ANC has decreased with increasing parity and maternal age. The inequity indices showed consistent inequities in 4 + ANC utilisation, and such inequities were increased between 2011 and 2014. In Bangladesh, the utilisation of any ANC rose steadily between 1994 and 2014, but progress in terms of 4 + ANC utilisation was much slower as the expectation was to achieve the national set target (50%: 4 + ANC utilisation) by 2016. Socio-economic inequities were observed in groups that failed to attend a 4 + ANC visit. Policymakers should pay special attention to increase the 4 + ANC coverage where this study can facilitate to identify the target groups whom need to be intervened on priority basis.

  12. Radiobiological effects of heavy ions and protons. [on cells of mammals, bacteria and viruses

    NASA Technical Reports Server (NTRS)

    Ryzhov, N. I.; Vorozhtsova, S. V.; Krasavin, Y. A.; Mashinskaya, T. Y.; Savchenko, N. Y.; Fedorov, B. S.; Khlaponina, V. F.; Shelegedin, V. N.; Gut, L.; Sabo, L.

    1974-01-01

    Radiobiological effects of heavy ions and protons are studied on cells of mammals, bacteria, viruses and DNA of bacteria. Results show that the dose effect dependence bears an exponential character; the reduction of RBE as LET of particle increases reflects the different character of microdistribution of absorbed energy in biological objects with different levels of biological organization.

  13. Fluctuations in energy loss and their implications for dosimetry and radiobiology

    NASA Technical Reports Server (NTRS)

    Baily, N. A.; Steigerwalt, J. E.

    1972-01-01

    Serious consideration of the physics of energy deposition indicates that a fundamental change in the interpretation of absorbed dose is required at least for considerations of effects in biological systems. In addition, theoretical approaches to radiobiology and microdosimetry seem to require statistical considerations incorporating frequency distributions of the magnitude of the event sizes within the volume of interest.

  14. Comparison of treatment plans: a retrospective study by the method of radiobiological evaluation

    NASA Astrophysics Data System (ADS)

    Puzhakkal, Niyas; Kallikuzhiyil Kochunny, Abdullah; Manthala Padannayil, Noufal; Singh, Navin; Elavan Chalil, Jumanath; Kulangarakath Umer, Jamshad

    2016-09-01

    There are many situations in radiotherapy where multiple treatment plans need to be compared for selection of an optimal plan. In this study we performed the radiobiological method of plan evaluation to verify the treatment plan comparison procedure of our clinical practice. We estimated and correlated various radiobiological dose indices with physical dose metrics for a total of 30 patients representing typical cases of head and neck, prostate and brain tumors. Three sets of plans along with a clinically approved plan (final plan) treated by either Intensity Modulated Radiation Therapy (IMRT) or Rapid Arc (RA) techniques were considered. The study yielded improved target coverage for final plans, however, no appreciable differences in doses and the complication probabilities of organs at risk were noticed. Even though all four plans showed adequate dose distributions, from dosimetric point of view, the final plan had more acceptable dose distribution. The estimated biological outcome and dose volume histogram data showed least differences between plans for IMRT when compared to RA. Our retrospective study based on 120 plans, validated the radiobiological method of plan evaluation. The tumor cure or normal tissue complication probabilities were found to be correlated with the corresponding physical dose indices.

  15. Fission neutron source in Rome

    NASA Astrophysics Data System (ADS)

    Coppola, Mario; Di Majo, V.; Ingrao, G.; Rebessi, S.; Testa, A.

    1997-02-01

    A fission neutron source is operating in Rome at the ENEA Casaccia Research Center since 1971, consisting of a low power fast reactor named RSV-Tapiro. it is employed for a variety of experiments, including dosimetry, material testing, radiation protection and biology. In particular, application to experimental radiobiology includes studies of the biological action of neutrons in the whole-body irradiated animal, or in specialized systems in vivo or in vitro. For his purpose a vertical irradiation facility was originally constructed. Recently, a new horizontal irradiation facility has been designed to allow the exposure of larger samples or larger sample batches at one time. Dosimetry at the sample irradiation positions is routinely carried out by the conventional method of using two ion chambers. This physical dosimetry has recently been compared with the results of biological dosimetry based on the detection of chromosomal aberrations in peripheral blood human lymphocytes irradiated in vitro. A characterization of the radiation quality in the two configurations has been carried out by tissue equivalent proportional counter microdosimetry measurements. Information about the main characteristics of the reactor and the two irradiation facilities is provided and relevant results of the various measurements are summarized. Radiobiological results obtained using this neutron source are also briefly outlined.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prather, J. C.; Smith, S. K.; Watson, C. R.

    The National Radiobiology Archives is a comprehensive effort to gather, organize, and catalog original data, representative specimens, and supporting materials related to significant radiobiology studies. This provides researchers with information for analyses which compare or combine results of these and other studies and with materials for analysis by advanced molecular biology techniques. This Programmer's Guide document describes the database access software, NRADEMO, and the subset loading script NRADEMO/MAINT/MAINTAIN, which comprise the National Laboratory Archives Distributed Access Package. The guide is intended for use by an experienced database management specialist. It contains information about the physical and logical organization of themore » software and data files. It also contains printouts of all the scripts and associated batch processing files. It is part of a suite of documents published by the National Radiobiology Archives.« less

  17. Comparison of dosimetric and radiobiological parameters on plans for prostate stereotactic body radiotherapy using an endorectal balloon for different dose-calculation algorithms and delivery-beam modes

    NASA Astrophysics Data System (ADS)

    Kang, Sang-Won; Suh, Tae-Suk; Chung, Jin-Beom; Eom, Keun-Yong; Song, Changhoon; Kim, In-Ah; Kim, Jae-Sung; Lee, Jeong-Woo; Cho, Woong

    2017-02-01

    The purpose of this study was to evaluate the impact of dosimetric and radiobiological parameters on treatment plans by using different dose-calculation algorithms and delivery-beam modes for prostate stereotactic body radiation therapy using an endorectal balloon. For 20 patients with prostate cancer, stereotactic body radiation therapy (SBRT) plans were generated by using a 10-MV photon beam with flattening filter (FF) and flattening-filter-free (FFF) modes. The total treatment dose prescribed was 42.7 Gy in 7 fractions to cover at least 95% of the planning target volume (PTV) with 95% of the prescribed dose. The dose computation was initially performed using an anisotropic analytical algorithm (AAA) in the Eclipse treatment planning system (Varian Medical Systems, Palo Alto, CA) and was then re-calculated using Acuros XB (AXB V. 11.0.34) with the same monitor units and multileaf collimator files. The dosimetric and the radiobiological parameters for the PTV and organs at risk (OARs) were analyzed from the dose-volume histogram. An obvious difference in dosimetric parameters between the AAA and the AXB plans was observed in the PTV and rectum. Doses to the PTV, excluding the maximum dose, were always higher in the AAA plans than in the AXB plans. However, doses to the other OARs were similar in both algorithm plans. In addition, no difference was observed in the dosimetric parameters for different delivery-beam modes when using the same algorithm to generate plans. As a result of the dosimetric parameters, the radiobiological parameters for the two algorithm plans presented an apparent difference in the PTV and the rectum. The average tumor control probability of the AAA plans was higher than that of the AXB plans. The average normal tissue complication probability (NTCP) to rectum was lower in the AXB plans than in the AAA plans. The AAA and the AXB plans yielded very similar NTCPs for the other OARs. In plans using the same algorithms, the NTCPs for delivery-beam modes showed no differences. This study demonstrated that the dosimetric and the radiobiological parameters for the PTV and the rectum affected the dose-calculation algorithms for prostate SBRT using an endorectal balloon. However, the dosimetric and the radiobiological parameters in the AAA and the AXB plans for other OARs were similar. Furthermore, difference between the dosimetric and the radiobiological parameters for different delivery-beam modes were not found when the same algorithm was used to generate the treatment plan.

  18. Studies Relative to the Radiosensitivity of Man: Based on Retrospective Evaluations of Therapeutic and Accidental Total-Body Irradiation

    NASA Technical Reports Server (NTRS)

    Ricks, R. C. (Compiler); Lushbaugh, C. C. (Compiler)

    1975-01-01

    The radiobiologic studies carried out with joint (AEC) ERDA and NASA support during the years 1964 to 1974 at the Medical Division of Oak Ridge Associated Universities are presented. The physiologic data generated were similar in many ways to those previously observed in other medical radiobiologic experiences. They differed, however, in the methods of data acquisition and analysis. Instead of more conventional analytical methods, pulmonary impedance was recorded and quantitated as a measure of radiation-induced gastrointestinal distress and fatiguability. While refinements in dose response related to gastrointestinal distress were accomplished, it was also found that through the use of Fourier analysis of pulmonary impedance waveform GI distress could easily be recognized and quantified even when the initial stages of nausea were below the subjects subjective level of recognition. The results demonstrate that change in pulmonary impedance waveform closely parallel well-defined stages of GI distress, i.e., initial nausea, a progressive increase in nausea, and finally vomiting episodes.

  19. Organ culture as a technique for casual embryology and its application in radiobiology (in German)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    BORGHESE, ELIO

    1961-11-01

    The classical methods of experimental embryology in amplubia are compared with the more recently introduced technique of culture in vitro of embryonic organs of warmblooded animals. Some isolation and recombination experiments carried out by means of organ culture are described. It is shown, by examples taken from research in progress, how this technique is applicable radiobiological experiments.

  20. Radiation transport codes for potential applications related to radiobiology and radiotherapy using protons, neutrons, and negatively charged pions

    NASA Technical Reports Server (NTRS)

    Armstrong, T. W.

    1972-01-01

    Several Monte Carlo radiation transport computer codes are used to predict quantities of interest in the fields of radiotherapy and radiobiology. The calculational methods are described and comparisions of calculated and experimental results are presented for dose distributions produced by protons, neutrons, and negatively charged pions. Comparisons of calculated and experimental cell survival probabilities are also presented.

  1. SU-F-T-680: Radiobiological Analysis of the Impact of Daily Patient Deformation and Setup Variations Through the Use of the Cone Beam CT and Deformable Image Registration in Lung Cancer IMRT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jurkovic, I; Stathakis, S; Markovic, M

    Purpose: To estimate the dose distributions delivered to the patient in each treatment fraction using deformable image registration (DIR) and assess the radiobiological impact of the inter-fraction variations due to patient deformation and setup. Methods: The work is based on the cone beam CT (CBCT) images and treatment plans of two lung cancer patients. Both patients were treated with intensity modulated radiation therapy (IMRT) to 66Gy in 2Gy/fraction. The treatment plans were exported from the treatment planning system (TPS) to the Velocity AI where DIR was performed and the same deformation matrix was used for the deformation of the plannedmore » dose distribution and organ contours to each CBCT dataset. A radiobiological analysis was performed based on the radiobiological parameters of the involved organs at risk (OARs) and planning target volume (PTV). Using the complication free tumor control probability (P+) index, differences in P+ were observed between each CBCT as well as between CBCT and planning dose distributions. Results: The optimal CBCT P? values ranged from 91.6 % to 94.8 % for patient #1 and from 88.8 % to 90.6 % for patient #2. At the dose level of the clinical prescription, the CBCT P+ values ranged from 80.3% to 80.7% for patient #1 and from 80.7% to 81.0% for the patient #2. The planning CT P+ values were 81.0% and 80.7% for the two patients, respectively. These differences emphasize the significance of using the radiobiological analysis when assessing changes in the dose distribution due to the tumor motion and lung deformations. Conclusion: Daily setup variations yield to differences in the actual dose delivered versus the planned one. The observed differences were rather small when only looking at the dosimetric comparison of the dose distributions, however the radiobiology analysis was able to detect clinically relevant differences among the studied dose distributions.« less

  2. Measurement of Proton-induced Radiation in Animal Tissue

    NASA Astrophysics Data System (ADS)

    Sękowski, P.; Skwira-Chalot, I.; Matulewicz, T.

    Hadron therapy, because of the dosimetric and radiobiological advantages, is more and more often used in tumour treatment. This treatment method leads also to the radioactive effects induced by energetic protons on nuclei. Nuclear reactions may lead to the production of radioactive isotopes. In the present experiment, two animal (human-like) tissue samples were irradiated with 60 MeV protons. Gamma-ray spectroscopy and lifetime measurements allowed identifying isotopes produced during the irradiation, e.g. $^{18}$F and $^{34m}$Cl.

  3. Ill-posed problem and regularization in reconstruction of radiobiological parameters from serial tumor imaging data

    NASA Astrophysics Data System (ADS)

    Chvetsov, Alevei V.; Sandison, George A.; Schwartz, Jeffrey L.; Rengan, Ramesh

    2015-11-01

    The main objective of this article is to improve the stability of reconstruction algorithms for estimation of radiobiological parameters using serial tumor imaging data acquired during radiation therapy. Serial images of tumor response to radiation therapy represent a complex summation of several exponential processes as treatment induced cell inactivation, tumor growth rates, and the rate of cell loss. Accurate assessment of treatment response would require separation of these processes because they define radiobiological determinants of treatment response and, correspondingly, tumor control probability. However, the estimation of radiobiological parameters using imaging data can be considered an inverse ill-posed problem because a sum of several exponentials would produce the Fredholm integral equation of the first kind which is ill posed. Therefore, the stability of reconstruction of radiobiological parameters presents a problem even for the simplest models of tumor response. To study stability of the parameter reconstruction problem, we used a set of serial CT imaging data for head and neck cancer and a simplest case of a two-level cell population model of tumor response. Inverse reconstruction was performed using a simulated annealing algorithm to minimize a least squared objective function. Results show that the reconstructed values of cell surviving fractions and cell doubling time exhibit significant nonphysical fluctuations if no stabilization algorithms are applied. However, after applying a stabilization algorithm based on variational regularization, the reconstruction produces statistical distributions for survival fractions and doubling time that are comparable to published in vitro data. This algorithm is an advance over our previous work where only cell surviving fractions were reconstructed. We conclude that variational regularization allows for an increase in the number of free parameters in our model which enables development of more-advanced parameter reconstruction algorithms.

  4. Gender and the utilisation of health services in the Ashanti Region, Ghana.

    PubMed

    Buor, Daniel

    2004-09-01

    The survey seeks to structure a model for gender-based health services utilisation for the Ashanti Region of Ghana, and in addition, recommend intervention measures to ensure gender equity in the utilisation of health services. A sample size of 650 covered over 3108 houses, and the main research instruments were the questionnaire and formal interview. A multiple regression model is used for the analysis of the relationship between the complex independent variables and utilisation by gender. Results show that although females have a greater need for health services than males, they do not utilise health services as much. Secondly, whereas quality of service, health status, service cost and education have greater effect on male utilisation than females, distance and income have higher impact on female utilisation. It is recommended that, to ensure equity in health care utilisation, females be empowered through increased access to formal education and sustainable income opportunities. The introduction of a national health insurance scheme is also recommended to ensure adequate access by both sexes.

  5. An Expanded Multi-scale Monte Carlo Simulation Method for Personalized Radiobiological Effect Estimation in Radiotherapy: a feasibility study

    NASA Astrophysics Data System (ADS)

    Zhang, Ying; Feng, Yuanming; Wang, Wei; Yang, Chengwen; Wang, Ping

    2017-03-01

    A novel and versatile “bottom-up” approach is developed to estimate the radiobiological effect of clinic radiotherapy. The model consists of multi-scale Monte Carlo simulations from organ to cell levels. At cellular level, accumulated damages are computed using a spectrum-based accumulation algorithm and predefined cellular damage database. The damage repair mechanism is modeled by an expanded reaction-rate two-lesion kinetic model, which were calibrated through replicating a radiobiological experiment. Multi-scale modeling is then performed on a lung cancer patient under conventional fractionated irradiation. The cell killing effects of two representative voxels (isocenter and peripheral voxel of the tumor) are computed and compared. At microscopic level, the nucleus dose and damage yields vary among all nucleuses within the voxels. Slightly larger percentage of cDSB yield is observed for the peripheral voxel (55.0%) compared to the isocenter one (52.5%). For isocenter voxel, survival fraction increase monotonically at reduced oxygen environment. Under an extreme anoxic condition (0.001%), survival fraction is calculated to be 80% and the hypoxia reduction factor reaches a maximum value of 2.24. In conclusion, with biological-related variations, the proposed multi-scale approach is more versatile than the existing approaches for evaluating personalized radiobiological effects in radiotherapy.

  6. Standards and Methodologies for Characterizing Radiobiological Impact of High-Z Nanoparticles

    PubMed Central

    Subiel, Anna; Ashmore, Reece; Schettino, Giuseppe

    2016-01-01

    Research on the application of high-Z nanoparticles (NPs) in cancer treatment and diagnosis has recently been the subject of growing interest, with much promise being shown with regards to a potential transition into clinical practice. In spite of numerous publications related to the development and application of nanoparticles for use with ionizing radiation, the literature is lacking coherent and systematic experimental approaches to fully evaluate the radiobiological effectiveness of NPs, validate mechanistic models and allow direct comparison of the studies undertaken by various research groups. The lack of standards and established methodology is commonly recognised as a major obstacle for the transition of innovative research ideas into clinical practice. This review provides a comprehensive overview of radiobiological techniques and quantification methods used in in vitro studies on high-Z nanoparticles and aims to provide recommendations for future standardization for NP-mediated radiation research. PMID:27446499

  7. OFFICE RADIOBIOLOGY AND THE TEST OF DIVIDED-DOSE IRRADIATION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scanlon, P.W.

    1963-08-01

    A simple and quantitatively accurate radiobiologic test system for office use by the clinical radiotherapist is described. Radiation inhibition of Lemna minor, or duckweed grown in an aquarium, forms the basis of the test system. Results are reported from radiation-inhibition studies using this system with time-dose variables appropriate to the radiation dose. The system proved adequate for testing the relative biologic effectiveness of the various quantities of radiation employed in clinical radiotherapy. (C.H.)

  8. Feasibility of BNCT radiobiological experiments at the HYTHOR facility

    NASA Astrophysics Data System (ADS)

    Esposito, J.; Ceballos, C.; Soncin, M.; Fabris, C.; Friso, E.; Moro, D.; Colautti, P.; Jori, G.; Rosi, G.; Nava, E.

    2008-06-01

    HYTHOR (HYbrid Thermal spectrum sHifter tapirO Reactor) is a new thermal-neutron irradiation facility, which was installed and became operative in mid 2005 at the TAPIRO (TAratura PIla Rapida potenza 0) fast reactor, in the Casaccia research centre (near Rome) of ENEA (Ente per le Nuove tecnologie Energia ed Ambiente). The facility has been designed for in vivo radiobiological studies. In HYTHOR irradiation cavity, 1-6 mice can be simultaneously irradiated to study skin melanoma treatments with the BNCT (boron neutron capture therapy). The therapeutic effects of HYTHOR radiation field on mouse melanoma has been studied as a preliminary investigation before studying the tumour local control due to boron neutron capture effect after boronated molecule injection. The method to properly irradiate small animals has been precisely defined. Results show that HYTHOR radiation field is by itself effective in reducing the tumour-growth rate. This finding has to be taken into account in studying the effectiveness of new 10B carriers. A method to properly measure the reduction of the tumour-growth rate is reported and discussed.

  9. SU-E-T-398: Evaluation of Radiobiological Parameters Using Serial Tumor Imaging During Radiotherapy as An Inverse Ill-Posed Problem

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chvetsov, A; Sandison, G; Schwartz, J

    Purpose: Combination of serial tumor imaging with radiobiological modeling can provide more accurate information on the nature of treatment response and what underlies resistance. The purpose of this article is to improve the algorithms related to imaging-based radiobilogical modeling of tumor response. Methods: Serial imaging of tumor response to radiation therapy represents a sum of tumor cell sensitivity, tumor growth rates, and the rate of cell loss which are not separated explicitly. Accurate treatment response assessment would require separation of these radiobiological determinants of treatment response because they define tumor control probability. We show that the problem of reconstruction ofmore » radiobiological parameters from serial imaging data can be considered as inverse ill-posed problem described by the Fredholm integral equation of the first kind because it is governed by a sum of several exponential processes. Therefore, the parameter reconstruction can be solved using regularization methods. Results: To study the reconstruction problem, we used a set of serial CT imaging data for the head and neck cancer and a two-level cell population model of tumor response which separates the entire tumor cell population in two subpopulations of viable and lethally damage cells. The reconstruction was done using a least squared objective function and a simulated annealing algorithm. Using in vitro data for radiobiological parameters as reference data, we shown that the reconstructed values of cell surviving fractions and potential doubling time exhibit non-physical fluctuations if no stabilization algorithms are applied. The variational regularization allowed us to obtain statistical distribution for cell surviving fractions and cell number doubling times comparable to in vitro data. Conclusion: Our results indicate that using variational regularization can increase the number of free parameters in the model and open the way to development of more advanced algorithms which take into account tumor heterogeneity, for example, related to hypoxia.« less

  10. Direct evaluation of radiobiological parameters from clinical data in the case of ion beam therapy: an alternative approach to the relative biological effectiveness.

    PubMed

    Cometto, A; Russo, G; Bourhaleb, F; Milian, F M; Giordanengo, S; Marchetto, F; Cirio, R; Attili, A

    2014-12-07

    The relative biological effectiveness (RBE) concept is commonly used in treatment planning for ion beam therapy. Whether models based on in vitro/in vivo RBE data can be used to predict human response to treatments is an open issue. In this work an alternative method, based on an effective radiobiological parameterization directly derived from clinical data, is presented. The method has been applied to the analysis of prostate cancer trials with protons and carbon ions.Prostate cancer trials with proton and carbon ion beams reporting 5 year-local control (LC5) and grade 2 (G2) or higher genitourinary toxicity rates (TOX) were selected from literature to test the method. Treatment simulations were performed on a representative subset of patients to produce dose and linear energy transfer distribution, which were used as explicative physical variables for the radiobiological modelling. Two models were taken into consideration: the microdosimetric kinetic model (MKM) and a linear model (LM). The radiobiological parameters of the LM and MKM were obtained by coupling them with the tumor control probability and normal tissue complication probability models to fit the LC5 and TOX data through likelihood maximization. The model ranking was based on the Akaike information criterion.Results showed large confidence intervals due to the limited variety of available treatment schedules. RBE values, such as RBE = 1.1 for protons in the treated volume, were derived as a by-product of the method, showing a consistency with current approaches. Carbon ion RBE values were also derived, showing lower values than those assumed for the original treatment planning in the target region, whereas higher values were found in the bladder. Most importantly, this work shows the possibility to infer the radiobiological parametrization for proton and carbon ion treatment directly from clinical data.

  11. [Systemic approach to radiobiological studies].

    PubMed

    Bulanova, K Ia; Lobanok, L M

    2004-01-01

    The principles of information theory were applied for analysis of radiobiological effects. The perception of ionizing radiations as a signal enables living organism to discern their benefits or harm, to react to absolute and relatively small deviations, to keep the logic and chronicle of events, to use the former experience for reacting in presence, to forecast consequences. The systemic analysis of organism's response to ionizing radiations allows explaining the peculiarities of effects of different absorbed doses, hormesis, apoptosis, remote consequences and other post-radiation effects.

  12. Optimization of the Temporal Pattern of Applied Radiation Dose: Implication for the Treatment of Prostate Cancer

    DTIC Science & Technology

    2009-03-01

    environment II.A: Characterization of dosimetry in IMRT radiobiological experiment phantom using TLDs and film. (7-10 mos.) Objectives: 1... dosimetry with TLDs and film. (8-10 mos.) 4. Analysis of measured dosimetry with TLDs and film compared to predicted dosimetry from treatment...cells were). Dosimetry in the phantom was assessed with film and monitor units were calculated accordingly to deliver the desired dose. Once in

  13. Research in radiobiology. Annual report of work in progress in the internal irradiation program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1979-03-31

    The toxicity, retention, biological effects, distribution, decorporation and measuring techniques of radionuclides are discussed. Calculations of trabecular bone formation rates from tetracycline labeling is included. The characteristics of trabecular bone in the Rhesus monkey are discussed. Studies on the early retention and distribution of radium 224 in beagles are included. Studies on the decorporation of plutonium and americium in dogs by DTPA and salicylic acid are presented.

  14. AFRRI (Armed Forces Radiobiology Research Institute) Reports, April-June 1985.

    DTIC Science & Technology

    1985-01-01

    endotoxins derived from gram-negative bacteria are in- 80 - volved [21,30]. Intravenously administered 60 endotoxin localizes within the liver, being I> 160...hypothesis of histamine involve- AUKLAND, K., BOWER, B. R., AND BERLINER, R. W. ment. (1964). Measurement of local blood flow with hydrogengas. (’ire. Res...naphthalene to pentacene for example, the optical ab- sorption spectrum shows a significant increase in the contribu- tion of states that have ionic

  15. Effects of radiobiological uncertainty on vehicle and habitat shield design for missions to the moon and Mars

    NASA Technical Reports Server (NTRS)

    Wilson, John W.; Nealy, John E.; Schimmerling, Walter; Cucinotta, Francis A.; Wood, James S.

    1993-01-01

    Some consequences of uncertainties in radiobiological risk due to galactic cosmic ray (GCR) exposure are analyzed for their effect on engineering designs for the first lunar outpost and a mission to explore Mars. This report presents the plausible effect of biological uncertainties, the design changes necessary to reduce the uncertainties to acceptable levels for a safe mission, and an evaluation of the mission redesign cost. Estimates of the amount of shield mass required to compensate for radiobiological uncertainty are given for a simplified vehicle and habitat. The additional amount of shield mass required to provide a safety factor for uncertainty compensation is calculated from the expected response to GCR exposure. The amount of shield mass greatly increases in the estimated range of biological uncertainty, thus, escalating the estimated cost of the mission. The estimates are used as a quantitative example for the cost-effectiveness of research in radiation biophysics and radiation physics.

  16. Influence of oxygen on the chemical stage of radiobiological mechanism

    NASA Astrophysics Data System (ADS)

    Barilla, Jiří; Lokajíček, Miloš V.; Pisaková, Hana; Simr, Pavel

    2016-07-01

    The simulation of the chemical stage of radiobiological mechanism may be very helpful in studying the radiobiological effect of ionizing radiation when the water radical clusters formed by the densely ionizing ends of primary or secondary charged particle may form DSBs damaging DNA molecules in living cells. It is possible to study not only the efficiency of individual radicals but also the influence of other species or radiomodifiers (mainly oxygen) being present in water medium during irradiation. The mathematical model based on Continuous Petri nets (proposed by us recently) will be described. It makes it possible to analyze two main processes running at the same time: chemical radical reactions and the diffusion of radical clusters formed during energy transfer. One may study the time change of radical concentrations due to the chemical reactions running during diffusion process. Some orientation results concerning the efficiency of individual radicals in DSB formation (in the case of Co60 radiation) will be presented; the influence of oxygen present in water medium during irradiation will be shown, too.

  17. An analysis of partial efficiencies of energy utilisation of different macronutrients by barramundi (Lates calcarifer) shows that starch restricts protein utilisation in carnivorous fish.

    PubMed

    Glencross, Brett D; Blyth, David; Bourne, Nicholas; Cheers, Susan; Irvin, Simon; Wade, Nicholas M

    2017-02-01

    This study examined the effect of including different dietary proportions of starch, protein and lipid, in diets balanced for digestible energy, on the utilisation efficiencies of dietary energy by barramundi (Lates calcarifer). Each diet was fed at one of three ration levels (satiety, 80 % of initial satiety and 60 % of initial satiety) for a 42-d period. Fish performance measures (weight gain, feed intake and feed conversion ratio) were all affected by dietary energy source. The efficiency of energy utilisation was significantly reduced in fish fed the starch diet relative to the other diets, but there were no significant effects between the other macronutrients. This reduction in efficiency of utilisation was derived from a multifactorial change in both protein and lipid utilisation. The rate of protein utilisation deteriorated as the amount of starch included in the diet increased. Lipid utilisation was most dramatically affected by inclusion levels of lipid in the diet, with diets low in lipid producing component lipid utilisation rates well above 1·3, which indicates substantial lipid synthesis from other energy sources. However, the energetic cost of lipid gain was as low as 0·65 kJ per kJ of lipid deposited, indicating that barramundi very efficiently store energy in the form of lipid, particularly from dietary starch energy. This study defines how the utilisation efficiency of dietary digestible energy by barramundi is influenced by the macronutrient source providing that energy, and that the inclusion of starch causes problems with protein utilisation in this species.

  18. On the use of published radiobiological parameters and the evaluation of NTCP models regarding lung pneumonitis in clinical breast radiotherapy.

    PubMed

    Svolos, Patricia; Tsougos, Ioannis; Kyrgias, Georgios; Kappas, Constantine; Theodorou, Kiki

    2011-04-01

    In this study we sought to evaluate and accent the importance of radiobiological parameter selection and implementation to the normal tissue complication probability (NTCP) models. The relative seriality (RS) and the Lyman-Kutcher-Burman (LKB) models were studied. For each model, a minimum and maximum set of radiobiological parameter sets was selected from the overall published sets applied in literature and a theoretical mean parameter set was computed. In order to investigate the potential model weaknesses in NTCP estimation and to point out the correct use of model parameters, these sets were used as input to the RS and the LKB model, estimating radiation induced complications for a group of 36 breast cancer patients treated with radiotherapy. The clinical endpoint examined was Radiation Pneumonitis. Each model was represented by a certain dose-response range when the selected parameter sets were applied. Comparing the models with their ranges, a large area of coincidence was revealed. If the parameter uncertainties (standard deviation) are included in the models, their area of coincidence might be enlarged, constraining even greater their predictive ability. The selection of the proper radiobiological parameter set for a given clinical endpoint is crucial. Published parameter values are not definite but should be accompanied by uncertainties, and one should be very careful when applying them to the NTCP models. Correct selection and proper implementation of published parameters provides a quite accurate fit of the NTCP models to the considered endpoint.

  19. Role of particle radiotherapy in the management of head and neck cancer.

    PubMed

    Laramore, George E

    2009-05-01

    Modern imaging techniques and powerful computers allow a radiation oncologist to design treatments delivering higher doses of radiation than previously possible. Dose distributions imposed by the physics of 'standard' photon and electron beams limit further dose escalation. Hadron radiotherapy offers advantages in either dose distribution and/or improved radiobiology that may significantly improve the treatment of certain head and neck malignancies. Clinical studies support the effectiveness of fast-neutron radiotherapy in the treatment of major and minor salivary gland tumors. Data show highly favorable outcomes with proton radiotherapy for skull-base malignancies and tumors near highly critical normal tissues compared with that expected with standard radiotherapy. Heavy-ion radiotherapy clinical studies are mainly being conducted with fully stripped carbon ions, and limited data seem to indicate a possible improvement over proton radiotherapy for the same subset of radioresistant tumors where neutrons show a benefit over photons. Fast-neutron radiotherapy has different radiobiological properties compared with standard radiotherapy but similar depth dose distributions. Its role in the treatment of head and neck cancer is currently limited to salivary gland malignancies and certain radioresistant tumors such as sarcomas. Protons have the same radiobiological properties as standard radiotherapy beams but more optimal depth dose distributions, making it particularly advantageous when treating tumors adjacent to highly critical structures. Heavy ions combine the radiobiological properties of fast neutrons with the physical dose distributions of protons, and preliminary data indicate their utility for radioresistant tumors adjacent to highly critical structures.

  20. Analytical calculation of proton linear energy transfer in voxelized geometries including secondary protons

    NASA Astrophysics Data System (ADS)

    Sanchez-Parcerisa, D.; Cortés-Giraldo, M. A.; Dolney, D.; Kondrla, M.; Fager, M.; Carabe, A.

    2016-02-01

    In order to integrate radiobiological modelling with clinical treatment planning for proton radiotherapy, we extended our in-house treatment planning system FoCa with a 3D analytical algorithm to calculate linear energy transfer (LET) in voxelized patient geometries. Both active scanning and passive scattering delivery modalities are supported. The analytical calculation is much faster than the Monte-Carlo (MC) method and it can be implemented in the inverse treatment planning optimization suite, allowing us to create LET-based objectives in inverse planning. The LET was calculated by combining a 1D analytical approach including a novel correction for secondary protons with pencil-beam type LET-kernels. Then, these LET kernels were inserted into the proton-convolution-superposition algorithm in FoCa. The analytical LET distributions were benchmarked against MC simulations carried out in Geant4. A cohort of simple phantom and patient plans representing a wide variety of sites (prostate, lung, brain, head and neck) was selected. The calculation algorithm was able to reproduce the MC LET to within 6% (1 standard deviation) for low-LET areas (under 1.7 keV μm-1) and within 22% for the high-LET areas above that threshold. The dose and LET distributions can be further extended, using radiobiological models, to include radiobiological effectiveness (RBE) calculations in the treatment planning system. This implementation also allows for radiobiological optimization of treatments by including RBE-weighted dose constraints in the inverse treatment planning process.

  1. Analytical calculation of proton linear energy transfer in voxelized geometries including secondary protons.

    PubMed

    Sanchez-Parcerisa, D; Cortés-Giraldo, M A; Dolney, D; Kondrla, M; Fager, M; Carabe, A

    2016-02-21

    In order to integrate radiobiological modelling with clinical treatment planning for proton radiotherapy, we extended our in-house treatment planning system FoCa with a 3D analytical algorithm to calculate linear energy transfer (LET) in voxelized patient geometries. Both active scanning and passive scattering delivery modalities are supported. The analytical calculation is much faster than the Monte-Carlo (MC) method and it can be implemented in the inverse treatment planning optimization suite, allowing us to create LET-based objectives in inverse planning. The LET was calculated by combining a 1D analytical approach including a novel correction for secondary protons with pencil-beam type LET-kernels. Then, these LET kernels were inserted into the proton-convolution-superposition algorithm in FoCa. The analytical LET distributions were benchmarked against MC simulations carried out in Geant4. A cohort of simple phantom and patient plans representing a wide variety of sites (prostate, lung, brain, head and neck) was selected. The calculation algorithm was able to reproduce the MC LET to within 6% (1 standard deviation) for low-LET areas (under 1.7 keV μm(-1)) and within 22% for the high-LET areas above that threshold. The dose and LET distributions can be further extended, using radiobiological models, to include radiobiological effectiveness (RBE) calculations in the treatment planning system. This implementation also allows for radiobiological optimization of treatments by including RBE-weighted dose constraints in the inverse treatment planning process.

  2. Radiobiologically optimized couch shift: A new localization paradigm using cone-beam CT for prostate radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Yimei, E-mail: yhuang2@hfhs.org; Gardner, Stephen J.; Wen, Ning

    2015-10-15

    Purpose: To present a novel positioning strategy which optimizes radiation delivery by utilizing radiobiological response knowledge and evaluate its use during prostate external beam radiotherapy. Methods: Five patients with low or intermediate risk prostate cancer were evaluated retrospectively in this IRB-approved study. For each patient, a VMAT plan with one 358° arc was generated on the planning CT (PCT) to deliver 78 Gy in 39 fractions. Five representative pretreatment cone beam CTs (CBCT) were selected for each patient. The CBCT images were registered to PCT by a human observer, which consisted of an initial automated registration with three degrees-of-freedom, followedmore » by manual adjustment for agreement at the prostate/rectal wall interface. To determine the optimal treatment position for each CBCT, a search was performed centering on the observer-matched position (OM-position) utilizing a score function based on radiobiological and dosimetric indices (EUD{sub prostate}, D99{sub prostate}, NTCP{sub rectum}, and NTCP{sub bladder}) for the prostate, rectum, and bladder. We termed the optimal treatment position the radiobiologically optimized couch shift position (ROCS-position). Results: The dosimetric indices, averaged over the five patients’ treatment plans, were (mean ± SD) 79.5 ± 0.3 Gy (EUD{sub prostate}), 78.2 ± 0.4 Gy (D99{sub prostate}), 11.1% ± 2.7% (NTCP{sub rectum}), and 46.9% ± 7.6% (NTCP{sub bladder}). The corresponding values from CBCT at the OM-positions were 79.5 ± 0.6 Gy (EUD{sub prostate}), 77.8 ± 0.7 Gy (D99{sub prostate}), 12.1% ± 5.6% (NTCP{sub rectum}), and 51.6% ± 15.2% (NTCP{sub bladder}), respectively. In comparison, from CBCT at the ROCS-positions, the dosimetric indices were 79.5 ± 0.6 Gy (EUD{sub prostate}), 77.3 ± 0.6 Gy (D99{sub prostate}), 8.0% ± 3.3% (NTCP{sub rectum}), and 46.9% ± 15.7% (NTCP{sub bladder}). Excessive NTCP{sub rectum} was observed on Patient 5 (19.5% ± 6.6%) corresponding to localization at OM-position, compared to the planned value of 11.7%. This was mitigated with radiobiologically optimized localization, resulting in a reduced NTCP{sub rectum} value of 11.3% ± 3.5%. Overall, the treatment position optimization resulted in similar target dose coverage with reduced risk to rectum. Conclusions: These encouraging results illustrate the potential advantage of applying radiobiologically optimized correction for online image-guided radiotherapy of prostate patients.« less

  3. Cost and utilisation of healthcare resources during rehabilitation after ankle fracture are not linked to health insurance, income, gender, or pain: an observational study.

    PubMed

    Lin, Chung-Wei Christine; Haas, Marion; Moseley, Anne M; Herbert, Robert D; Refshauge, Kathryn M

    2008-01-01

    What are the costs and utilisation of healthcare resources, their determinants, and quality of life for people attending outpatient physiotherapy after ankle fracture? Longitudinal observational study. Ninety-four adults (2 dropouts) following cast removal after isolated ankle fracture attending outpatient physiotherapy at three hospitals in Sydney, Australia. Costs incurred (direct healthcare costs and out-of-pocket costs) and utilisation of healthcare system resources were measured at 4, 8, 12, 16, 20, and 24 weeks. Quality of life was measured shortly after cast removal and at 4, 12, and 24 weeks. Factors known to influence costs and utilisation in other conditions (private health insurance, income level, gender, and pain) were also measured. The total cost per person was AUD 735 (SD 876) over 24 weeks. Outpatient physiotherapy accounted for the highest costs in both direct healthcare (39%) and out-of-pocket (42%) costs. Less than 20% of participants sought private non-medical care in addition to receiving outpatient physiotherapy. None of the factors investigated had a significant influence on costs and utilisation. Quality of life score improved over the 24 weeks by a mean of 6.1 points out of 45 (95% CI 5.2 to 6.9), with most of the improvement occurring in the domain of independent living. Information on costs and utilisation of healthcare resources can be used to plan health services, eg, the number of physiotherapy sessions required after ankle fracture. Private health insurance, income level, gender, or pain did not influence the costs or the decision behind seeking care over and above publicly-provided physiotherapy.

  4. Radiobiological Impact of Planning Techniques for Prostate Cancer in Terms of Tumor Control Probability and Normal Tissue Complication Probability

    PubMed Central

    Rana, S; Cheng, CY

    2014-01-01

    Background: The radiobiological models describe the effects of the radiation treatment on cancer and healthy cells, and the radiobiological effects are generally characterized by the tumor control probability (TCP) and normal tissue complication probability (NTCP). Aim: The purpose of this study was to assess the radiobiological impact of RapidArc planning techniques for prostate cancer in terms of TCP and normal NTCP. Subjects and Methods: A computed tomography data set of ten cases involving low-risk prostate cancer was selected for this retrospective study. For each case, two RapidArc plans were created in Eclipse treatment planning system. The double arc (DA) plan was created using two full arcs and the single arc (SA) plan was created using one full arc. All treatment plans were calculated with anisotropic analytical algorithm. Radiobiological modeling response evaluation was performed by calculating Niemierko's equivalent uniform dose (EUD)-based Tumor TCP and NTCP values. Results: For prostate tumor, the average EUD in the SA plans was slightly higher than in the DA plans (78.10 Gy vs. 77.77 Gy; P = 0.01), but the average TCP was comparable (98.3% vs. 98.3%; P = 0.01). In comparison to the DA plans, the SA plans produced higher average EUD to bladder (40.71 Gy vs. 40.46 Gy; P = 0.03) and femoral heads (10.39 Gy vs. 9.40 Gy; P = 0.03), whereas both techniques produced NTCP well below 0.1% for bladder (P = 0.14) and femoral heads (P = 0.26). In contrast, the SA plans produced higher average NTCP compared to the DA plans (2.2% vs. 1.9%; P = 0.01). Furthermore, the EUD to rectum was slightly higher in the SA plans (62.88 Gy vs. 62.22 Gy; P = 0.01). Conclusion: The SA and DA techniques produced similar TCP for low-risk prostate cancer. The NTCP for femoral heads and bladder was comparable in the SA and DA plans; however, the SA technique resulted in higher NTCP for rectum in comparison with the DA technique. PMID:24761232

  5. Combining the LKB NTCP model with radiosensitivity parameters to characterize toxicity of radionuclides based on a multiclonogen kidney model: a theoretical assessment.

    PubMed

    Lin, Hui; Jing, Jia; Xu, Liangfeng; Wu, Dongsheng; Xu, Yuanying

    2012-06-01

    The Lyman-Kutcher-Burman (LKB) normal tissue complication probability (NTCP) model is often used to estimate the damage level to normal tissue. However, it does not manifestly involve the influence of radiosensitivity parameters. This work replaces the generalized mean equivalent uniform dose (gEUD) with the equivalent uniform dose (EUD) in the LKB model to investigate the effect of a variety of radiobiological parameters on the NTCP to characterize the toxicity of five types of radionuclides. The dose for 50 % complication probability (D (50)) is replaced by the corresponding EUD for 50 % complication probability (EUD(50)). The properties of a variety of radiobiological characteristics, such as biologically effective dose (BED), NTCP, and EUD, for five types of radioisotope ((131)I, (186)Re, (188)Re, (90)Y, and (67)Cu) are investigated by various radiosensitivity parameters such as intrinsic radiosensitivity α, alpha-beta ratio α/β, cell repair half-time, cell mean clonogen doubling time, etc. The high-energy beta emitters ((90)Y and (188)Re) have high initial dose rate and mean absorbed dose per injected activity in kidney, and their kidney toxicity should be of greater concern if they are excreted through kidneys. The radiobiological effect of (188)Re changes most sharply with the radiobiological parameters due to its high-energy electrons and very short physical half-life. The dose for a probability of 50% injury within 5y (D (50/5)) 28 Gy for whole-kidney irradiation should be adjusted according to different radionuclides and different radiosensitivity of individuals. The D (50/5) of individuals with low α/β or low α, or low biological clearance half-time, will be less than 28 Gy. The 50 % complication probability dose for (67)Cu and (188)Re could be 25 Gy and 22 Gy. The same mean absorbed dose generally corresponds to different degrees of damage for tissues of different radiosensitivity and different radionuclides. The influence of various radiobiological parameters should be taken into consideration in the NTCP model.

  6. LDR vs. HDR brachytherapy for localized prostate cancer: the view from radiobiological models.

    PubMed

    King, Christopher R

    2002-01-01

    Permanent LDR brachytherapy and temporary HDR brachytherapy are competitive techniques for clinically localized prostate radiotherapy. Although a randomized trial will likely never be conducted comparing these two forms of brachytherapy, a comparative radiobiological modeling analysis proves useful in understanding some of their intrinsic differences, several of which could be exploited to improve outcomes. Radiobiological models based upon the linear quadratic equations are presented for fractionated external beam, fractionated (192)Ir HDR brachytherapy, and (125)I and (103)Pd LDR brachytherapy. These models incorporate the dose heterogeneities present in brachytherapy based upon patient-derived dose volume histograms (DVH) as well as tumor doubling times and repair kinetics. Radiobiological parameters are normalized to correspond to three accepted clinical risk factors based upon T-stage, PSA, and Gleason score to compare models with clinical series. Tumor control probabilities (TCP) for LDR and HDR brachytherapy (as monotherapy or combined with external beam) are compared with clinical bNED survival rates. Predictions are made for dose escalation with HDR brachytherapy regimens. Model predictions for dose escalation with external beam agree with clinical data and validate the models and their underlying assumptions. Both LDR and HDR brachytherapy achieve superior tumor control when compared with external beam at conventional doses (<70 Gy), but similar to results from dose escalation series. LDR brachytherapy as boost achieves superior tumor control than when used as monotherapy. Stage for stage, both LDR and current HDR regimens achieve similar tumor control rates, in agreement with current clinical data. HDR monotherapy with large-dose fraction sizes might achieve superior tumor control compared with LDR, especially if prostate cancer possesses a high sensitivity to dose fractionation (i.e., if the alpha/beta ratio is low). Radiobiological models support the current clinical evidence for equivalent outcomes in localized prostate cancer with either LDR or HDR brachytherapy using current dose regimens. However, HDR brachytherapy dose escalation regimens might be able to achieve higher biologically effective doses of irradiation in comparison to LDR, and hence improved outcomes. This advantage over LDR would be amplified should prostate cancer possess a high sensitivity to dose fractionation (i.e., a low alpha/beta ratio) as the current evidence suggests.

  7. SU-F-J-11: Radiobiologically Optimized Patient Localization During Prostate External Beam Localization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Y; Gardner, S; Liu, C

    2016-06-15

    Purpose: To present a novel positioning strategy which optimizes radiation delivery with radiobiological response knowledge, and to evaluate its application during prostate external beam radiotherapy. Methods: Ten patients with low or intermediate risk prostate cancer were evaluated retrospectively in this IRB-approved study. For each patient, a VMAT plan was generated on the planning CT (PCT) to deliver 78 Gy in 39 fractions with PTV = prostate + 7 mm margin, except for 5mm in the posterior direction. Five representative pretreatment CBCT images were selected for each patient, and prostate, rectum, and bladder were delineated on all CBCT images. Each CBCTmore » was auto-registered to the corresponding PCT. Starting from this auto-matched position (AM-position), a search for optimal treatment position was performed utilizing a score function based on radiobiological and dosimetric indices (D98-DTV, NTCP-rectum, and NTCP-bladder) for the daily target volume (DTV), rectum, and bladder. DTV was defined as prostate + 4 mm margin to account for intra-fraction motion as well as contouring variability on CBCT. We termed the optimal treatment position the radiobiologically optimized couch shift position (ROCS-position). Results: The indices, averaged over the 10 patients’ treatment plans, were (mean±SD): 77.7±0.2 Gy (D98-PTV), 12.3±2.7% (NTCP-rectum), and 53.2±11.2% (NTCP-bladder). The corresponding values calculated on all 50 CBCT images at the AM-positions were 72.9±11.3 Gy (D98-DTV), 15.8±6.4% (NTCP-rectum), and 53.0±21.1% (NTCP-bladder), respectively. In comparison, calculated on CBCT at the ROCS-positions, the indices were 77.0±2.1 Gy (D98-DTV), 12.1±5.7% (NTCP-rectum), and 60.7±16.4% (NTCP-bladder). Compared to autoregistration, ROCS-optimization recovered dose coverage to target volume and lowered the risk to rectum. Moreover, NTCPrectum for one patient remained high after ROCS-optimization and therefore could potentially benefit from adaptive planning. Conclusion: These encouraging results illustrate the potential utility of applying radiobiologically optimized correction for online image-guided radiotherapy of prostate patients.« less

  8. Manhattan transfer: lethal radiation, bone marrow transplantation, and the birth of stem cell biology, ca. 1942-1961.

    PubMed

    Kraft, Alison

    2009-01-01

    This study investigates how, in the late 1940s and 1950s, fears of nuclear accidents and nuclear warfare shaped postwar radiobiology. The new and intense forms of radiation generated by nuclear reactor technology, and which would be released in the event of a nuclear war, created concerns about a public-health hazard unprecedented in form and scale. Fears of inadvertent exposure to acute and potentially lethal radiation launched a search for anti-radiation therapies, out of which emerged the new technique of bone marrow transplantation (BMT). This study analyzes the use of BMT first as a research tool to explore the biological effects of ionizing radiation, and then as an adjunct to radiotherapy for the treatment of cancer. In highlighting how BMT became the province of different research and clinical constituencies, this study develops an understanding of the forces and contingencies that shaped its development. Exploring the emergence of BMT and the uses to which it was put, it reveals that BMT remained a technique in the making -- unstable and far from standardized, even as it became both a widely used research tool and rapidly made its way into the clinic. More broadly, it casts new light on one route through which the Manhattan Project influenced postwar radiobiology; it also affords new insights into one means by which radiobiology came to serve the interests of the Cold War state. In its focus on BMT this paper provides a new perspective on the evolving relationship between radiobiology and biomedicine in the postwar period.

  9. Radiobiological long-term accumulation of environmental alpha radioactivity in extracted human teeth and animal bones in Malaysia.

    PubMed

    Almayahi, B A; Tajuddin, A A; Jaafar, M S

    2014-03-01

    In this study, the radiobiological analysis of natural alpha emitters in extracted human teeth and animal bones from Malaysia was estimated. The microdistributions of alpha particles in tooth and bone samples were measured using CR-39 alpha-particle track detectors. The lowest and highest alpha emission rates in teeth in the Kedah and Perak states were 0.0080 ± 0.0005 mBq cm(-2) and 0.061 ± 0.008 mBq cm(-2), whereas those of bones in the Perlis and Kedah states were 0.0140 ± 0.0001 mBq cm(-2) and 0.7700 ± 0.0282 mBq cm(-2), respectively. The average alpha emission rate in male teeth was 0.0209 ± 0.0008 mBq cm(-2), whereas that of female teeth was 0.0199 ± 0.0010 mBq cm(-2). The alpha emission rate in teeth is higher in smokers (0.0228 ± 0.0008 mBq cm(-2)) than in non-smokers (0.0179 ± 0.0008 mBq cm(-2)). Such difference was found statistically significant (p < 0.01). Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Effect of Rosiglitazone on Radiation Damage in Bone Marrow Hemopoiesis

    NASA Astrophysics Data System (ADS)

    Benkő, Klára; Pintye, Éva; Szabó, Boglárka; Géresi, Krisztina; Megyeri, Attila; Benkő, Ilona

    2008-12-01

    To study radiobiological effects and drugs, which can modify radiation injury, has an importance if we would like to avoid harmful effects of radiation due to emergency situations or treat patients with malignant diseases by radiotherapy. During the long treatment schedules patients may be treated by not only anticancer but many other drugs because of accompanying diseases. These drugs may also modify radiobiological effects. Rosiglitazone pre-treatment proved to be myeloprotective and accelerated recovery of 5-fluorouracil-damaged bone marrow in our previous experiments. Our new studies are designed to evaluate whether rosiglitazone has similar beneficial effects in radiation-damaged hemopoiesis. Bone marrow damage was precipitated by total body irradiation (TBI) using single increasing doses (2-10 Gy) of γ—irradiation in groups of mice. Lethality was well correlated with damage in hemopoiesis measured by cellularity of bone marrow (LD50 values were 4.8 and 5.3 gray respectively). Rosiglitazone, an insulin-sensitizing drug, had no significant effect on bone marrow cellularity. Insulin resistance associated with obesity or diabetes mellitus type 2 is intensively growing among cancer patients requiring some kind of radiotherapy. Therefore it is important to know whether drugs used for their therapy can modify radiation effects.

  11. Radiobiological concepts for treatment planning of schemes that combines external beam radiotherapy and systemic targeted radiotherapy

    NASA Astrophysics Data System (ADS)

    Fabián Calderón Marín, Carlos; González González, Joaquín Jorge; Laguardia, Rodolfo Alfonso

    2017-09-01

    The combination of radiotherapy modalities with external bundles and systemic radiotherapy (CIERT) could be a reliable alternative for patients with multiple lesions or those where treatment planning maybe difficult because organ(s)-at-risk (OARs) constraints. Radiobiological models should have the capacity for predicting the biological irradiation response considering the differences in the temporal pattern of dose delivering in both modalities. Two CIERT scenarios were studied: sequential combination in which one modality is executed following the other one and concurrent combination when both modalities are running simultaneously. Expressions are provided for calculation of the dose-response magnitudes Tumor Control Probability (TCP) and Normal Tissue Complication Probability (NTCP). General results on radiobiological modeling using the linear-quadratic (LQ) model are also discussed. Inter-subject variation of radiosensitivity and volume irradiation effect in CIERT are studied. OARs should be under control during the planning in concurrent CIERT treatment as the administered activity is increased. The formulation presented here may be used for biological evaluation of prescriptions and biological treatment planning of CIERT schemes in clinical situation.

  12. Radiation safety and medical education: development and integration of a dedicated educational module into a radiology clerkship, outcomes assessment, and survey of medical students' perceptions.

    PubMed

    Koontz, Nicholas A; Gunderman, Richard B

    2012-04-01

    This study assesses the effect on medical student understanding of a new radiobiology and radiation safety module in a fourth-year radiology clerkship. A dedicated radiobiology and radiation safety module was incorporated into the fourth-year medical school radiology clerkship at our institution. Student understanding of the material was assessed via pretest and posttest. Statistical analysis was performed to assess significance of changes in student performance. In addition, we surveyed student perceptions of the importance of this material in medical education and practice. Monthly pretest mean scores ranged from 47.8% to 55.6%, with an average monthly pretest score of 50.3%. Monthly posttest mean scores ranged from 77.3% to 91.2%, with an average monthly posttest score of 83.9%. The improvement in exam scores after the educational intervention was statistically significant (all P < .01). The introduction of a new educational module can significantly improve medical student understanding of radiobiology and radiation safety. Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.

  13. Manned Mars mission radiation environment and radiobiology

    NASA Technical Reports Server (NTRS)

    Nachtwey, D. S.

    1986-01-01

    Potential radiation hazards to crew members on manned Mars missions are discussed. It deals briefly with radiation sources and environments likely to be encountered during various phases of such missions, providing quantitative estimates of these environments. Also provided are quantitative data and discussions on the implications of such radiation on the human body. Various sorts of protective measures are suggested. Recent re-evaluation of allowable dose limits by the National Council of Radiation Protection is discussed, and potential implications from such activity are assessed.

  14. Effect of active shortening on the rate of ATP utilisation by rabbit psoas muscle fibres

    PubMed Central

    Sun, Y-B; Hilber, K; Irving, M

    2001-01-01

    The rate of ATP utilisation during active shortening of single skinned fibres from rabbit psoas muscle at 10 °C was measured using an NADH-linked assay. Fibres were immersed in silicone oil and illuminated with 365 nm light. The amounts of NADH and carboxytetramethylrhodamine (CTMR) in the illuminated region of the fibre were measured simultaneously from fluorescence emission at 425–475 and 570–650 nm, respectively. The ratio of these two signals was used to determine the intracellular concentration of NADH, and thus the ATP utilisation, without interference from movements of the fibre with respect to the measuring light beam. The total extra ATP utilisation due to shortening (ΔATP) was determined by extrapolation of the steady isometric rates before and after shortening to the mid-point of the shortening period. ΔATP had a roughly linear dependence on the extent of shortening in the range 1–15% fibre length (L0) at a shortening velocity of 0.4 L0 s−1 from initial sarcomere length 2.7 μm. For shortening of 1%L0, ΔATP was 21 ± 1 μm (mean ±s.e.m., n = 3). The mean rate of ATP utilisation during ramp shortening of 10%L0 had a roughly linear dependence on shortening velocity in the range 0.05–1.2 L0 s−1. During unloaded shortening at 1.2 L0 s−1 the mean rate of ATP utilisation was 1.7 mm s−1, about 9 times the isometric rate. ΔATP was roughly independent of shortening velocity, and was 84 ± 9 μm (mean ±s.e.m., n = 6) for shortening of 10%L0. The implications of these results for mechanical-chemical coupling in muscle are discussed. The total ATP utilisation associated with shortening of 1%L0 is only about 17% of the concentration of the myosin heads in the fibre, suggesting that during isometric contraction either less than 17% of the myosin heads are attached to actin, or that heads can detach without commitment to ATP splitting. The fraction of myosin heads attached to actin during unloaded shortening is estimated from the rate of ATP utilisation to be less than 7%. PMID:11251058

  15. Radiobiological studies using gamma and x rays.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Potter, Charles Augustus; Longley, Susan W.; Scott, Bobby R.

    2013-02-01

    There are approximately 500 self-shielded research irradiators used in various facilities throughout the U.S. These facilities use radioactive sources containing either 137Cs or 60Co for a variety of biological investigations. A report from the National Academy of Sciences[1] described the issues with security of particular radiation sources and the desire for their replacement. The participants in this effort prepared two peer-reviewed publications to document the results of radiobiological studies performed using photons from 320-kV x rays and 137Cs on cell cultures and mice. The effectiveness of X rays was shown to vary with cell type.

  16. SU-F-T-670: From the OR to the Radiobiology Lab: The Journey of a Small X-Ray Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lehmann, J; The University of Sydney, Sydney, NSW; The University of Newcastle, Newcastle, NSW

    Purpose: Irradiation of small animal tumor models within laboratories is vital to radiobiological experiments. Often the animals are not able to be brought back into the lab after being taken out for irradiation. Cell biology laboratories benefit from irradiation capability available around the clock without regard to patient load in an associated radiotherapy clinic. Commercial systems are available, but bulky and expensive. Methods: An intraoperative kV irradiation system (IntraBeam™) designed to deliver spherical dose distributions to surgical cavities has been repurposed for the irradiation of cell plates and small laboratory animals. An applicator has been altered to allow for simple,more » open fields. Special collimators are being developed. BEAMnrc Monte Carlo simulations with the “NRC swept BEAM” source model have been performed to characterize the dose distributions, to develop optimal collimators and as basis for dose prescription. Measurements with radiochromic film and with an ionization chamber were performed to characterize the beam and to validate the simulations. Results: Using its highest setting (50 kV and 40 µA) the x-ray unit is capable of delivering dose rates over 1 Gy/min homogeneously to standard cell plates even without an optimized collimator. Smaller areas (tumors in animals) can be irradiated with significantly higher dose rates (> 20 Gy/min) depending on distance of the source to the tumor. The HVL was found to be 0.21 mm Al which means the shielding requirements for the device are easily achievable in the lab. Conclusion: A mobile irradiation facility is feasible. It will allow easier access to radiation for radiobiology experiments. The modified system is versatile in that for cell plates homogenous irradiations can be achieved through distance from the source, while for high dose rate small field irradiations the source can be brought in close proximity to the target.« less

  17. SU-G-TeP3-15: Radiation Dose Enhancement by Anatase TiO2NPs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Youkhana, E; Geso, M; Feltis, B

    2016-06-15

    Purpose: This work investigates radiation dose enhancement caused by TiO2 nanoparticles covering entire X-ray energy ranges used in radiation therapy. Methods: Anatase TiO2NPs crystal were synthesised and modified as hydrophilic and hydrophobic to disperse in culture-medium and halocarbons (PRESAGE chemical composition) respectively. TiO2NPs were characterised using TEM, XPS, XRD, TGA and FTIR. Various Concentrations have been utilised for determination of radiation-dose enhancement. This investigation is carried out in two ways; one using PRESAGE dosimeter/phantom and the other is radiobiological and based on in vitro study using two types of cell lines, Human Keratinocyte (HaCaT) and prostate cancer cell lines. Themore » x-ray used are both kilovoltage and megavoltage separately. The prepared PRESAGE dosimeters were scanned using optical CT scanner. Clonogenic and MTS assays were employed for cell cytotoxicity and viability measurements for determination of the levels of dose enhancement. Results: Significant about (50%, 45%) dose enhancement by TiO2-NPs for kV x-rays is measured in both ways (Presage and Cells study). Slightly more is detected with the cells. However, the dose enhancement with megavoltage beams was insignificant using Presage and under same conditions the cells survival curves indicates around 20% which is relatively high. This difference can only be attributed to some biochemical effects. Such as generation of reactive oxygen species (ROS), this can affect the cells while it can’t be detected by Presage. Elevation of hydroxyl radicals (•OH) of many orders is observed with the inclusion of TiO2-NPs in cells-medium. Conclusion: Dose enhancement inflicted by TiO2-NPs is proven to be significant with megavoltage beams and minimal with kV. The high dose enhancements obtained can be attributed to higher levels of ROS generated. Since MV beams are most commonly used, this research proves potential value for more efficient beam delivery. This has potential to be applied in future clinical radiotherapy applications The research is supported and funded by RMIT university-Melbourne/Australia.« less

  18. Radiobiological Effectiveness of Ultrashort Laser-Driven Electron Bunches: Micronucleus Frequency, Telomere Shortening and Cell Viability.

    PubMed

    Andreassi, Maria Grazia; Borghini, Andrea; Pulignani, Silvia; Baffigi, Federica; Fulgentini, Lorenzo; Koester, Petra; Cresci, Monica; Vecoli, Cecilia; Lamia, Debora; Russo, Giorgio; Panetta, Daniele; Tripodi, Maria; Gizzi, Leonida A; Labate, Luca

    2016-09-01

    Laser-driven electron accelerators are capable of producing high-energy electron bunches in shorter distances than conventional radiofrequency accelerators. To date, our knowledge of the radiobiological effects in cells exposed to electrons using a laser-plasma accelerator is still very limited. In this study, we compared the dose-response curves for micronucleus (MN) frequency and telomere length in peripheral blood lymphocytes exposed to laser-driven electron pulse and X-ray radiations. Additionally, we evaluated the effects on cell survival of in vitro tumor cells after exposure to laser-driven electron pulse compared to electron beams produced by a conventional radiofrequency accelerator used for intraoperative radiation therapy. Blood samples from two different donors were exposed to six radiation doses ranging from 0 to 2 Gy. Relative biological effectiveness (RBE) for micronucleus induction was calculated from the alpha coefficients for electrons compared to X rays (RBE = alpha laser/alpha X rays). Cell viability was monitored in the OVCAR-3 ovarian cancer cell line using trypan blue exclusion assay at day 3, 5 and 7 postirradiation (2, 4, 6, 8 and 10 Gy). The RBE values obtained by comparing the alpha values were 1.3 and 1.2 for the two donors. Mean telomere length was also found to be reduced in a significant dose-dependent manner after irradiation with both electrons and X rays in both donors studied. Our findings showed a radiobiological response as mirrored by the induction of micronuclei and shortening of telomere as well as by the reduction of cell survival in blood samples and cancer cells exposed in vitro to laser-generated electron bunches. Additional studies are needed to improve preclinical validation of the radiobiological characteristics and efficacy of laser-driven electron accelerators in the future.

  19. Mixed-field GCR Simulations for Radiobiological Research using Ground Based Accelerators

    NASA Astrophysics Data System (ADS)

    Kim, Myung-Hee Y.; Rusek, Adam; Cucinotta, Francis

    Space radiation is comprised of a large number of particle types and energies, which have differential ionization power from high energy protons to high charge and energy (HZE) particles and secondary neutrons produced by galactic cosmic rays (GCR). Ground based accelerators such as the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory (BNL) are used to simulate space radiation for radiobiology research and dosimetry, electronics parts, and shielding testing using mono-energetic beams for single ion species. As a tool to support research on new risk assessment models, we have developed a stochastic model of heavy ion beams and space radiation effects, the GCR Event-based Risk Model computer code (GERMcode). For radiobiological research on mixed-field space radiation, a new GCR simulator at NSRL is proposed. The NSRL-GCR simulator, which implements the rapid switching mode and the higher energy beam extraction to 1.5 GeV/u, can integrate multiple ions into a single simulation to create GCR Z-spectrum in major energy bins. After considering the GCR environment and energy limitations of NSRL, a GCR reference field is proposed after extensive simulation studies using the GERMcode. The GCR reference field is shown to reproduce the Z and LET spectra of GCR behind shielding within 20 percents accuracy compared to simulated full GCR environments behind shielding. A major challenge for space radiobiology research is to consider chronic GCR exposure of up to 3-years in relation to simulations with cell and animal models of human risks. We discuss possible approaches to map important biological time scales in experimental models using ground-based simulation with extended exposure of up to a few weeks and fractionation approaches at a GCR simulator.

  20. Mixed-field GCR Simulations for Radiobiological Research Using Ground Based Accelerators

    NASA Technical Reports Server (NTRS)

    Kim, Myung-Hee Y.; Rusek, Adam; Cucinotta, Francis A.

    2014-01-01

    Space radiation is comprised of a large number of particle types and energies, which have differential ionization power from high energy protons to high charge and energy (HZE) particles and secondary neutrons produced by galactic cosmic rays (GCR). Ground based accelerators such as the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory (BNL) are used to simulate space radiation for radiobiology research and dosimetry, electronics parts, and shielding testing using mono-energetic beams for single ion species. As a tool to support research on new risk assessment models, we have developed a stochastic model of heavy ion beams and space radiation effects, the GCR Event-based Risk Model computer code (GERMcode). For radiobiological research on mixed-field space radiation, a new GCR simulator at NSRL is proposed. The NSRL-GCR simulator, which implements the rapid switching mode and the higher energy beam extraction to 1.5 GeV/u, can integrate multiple ions into a single simulation to create GCR Z-spectrum in major energy bins. After considering the GCR environment and energy limitations of NSRL, a GCR reference field is proposed after extensive simulation studies using the GERMcode. The GCR reference field is shown to reproduce the Z and LET spectra of GCR behind shielding within 20% accuracy compared to simulated full GCR environments behind shielding. A major challenge for space radiobiology research is to consider chronic GCR exposure of up to 3-years in relation to simulations with cell and animal models of human risks. We discuss possible approaches to map important biological time scales in experimental models using ground-based simulation with extended exposure of up to a few weeks and fractionation approaches at a GCR simulator.

  1. Radiobiological Determination of Dose Escalation and Normal Tissue Toxicity in Definitive Chemoradiation Therapy for Esophageal Cancer☆

    PubMed Central

    Warren, Samantha; Partridge, Mike; Carrington, Rhys; Hurt, Chris; Crosby, Thomas; Hawkins, Maria A.

    2014-01-01

    Purpose This study investigated the trade-off in tumor coverage and organ-at-risk sparing when applying dose escalation for concurrent chemoradiation therapy (CRT) of mid-esophageal cancer, using radiobiological modeling to estimate local control and normal tissue toxicity. Methods and Materials Twenty-one patients with mid-esophageal cancer were selected from the SCOPE1 database (International Standard Randomised Controlled Trials number 47718479), with a mean planning target volume (PTV) of 327 cm3. A boost volume, PTV2 (GTV + 0.5 cm margin), was created. Radiobiological modeling of tumor control probability (TCP) estimated the dose required for a clinically significant (+20%) increase in local control as 62.5 Gy/25 fractions. A RapidArc (RA) plan with a simultaneously integrated boost (SIB) to PTV2 (RA62.5) was compared to a standard dose plan of 50 Gy/25 fractions (RA50). Dose-volume metrics and estimates of normal tissue complication probability (NTCP) for heart and lungs were compared. Results Clinically acceptable dose escalation was feasible for 16 of 21 patients, with significant gains (>18%) in tumor control from 38.2% (RA50) to 56.3% (RA62.5), and only a small increase in predicted toxicity: median heart NTCP 4.4% (RA50) versus 5.6% (RA62.5) P<.001 and median lung NTCP 6.5% (RA50) versus 7.5% (RA62.5) P<.001. Conclusions Dose escalation to the GTV to improve local control is possible when overlap between PTV and organ-at-risk (<8% heart volume and <2.5% lung volume overlap for this study) generates only negligible increase in lung or heart toxicity. These predictions from radiobiological modeling should be tested in future clinical trials. PMID:25304796

  2. Radiobiological evaluation of simultaneously dose-escalated versus non-escalated intensity-modulated radiation therapy for patients with upper thoracic esophageal cancer.

    PubMed

    Huang, Bao-Tian; Wu, Li-Li; Guo, Long-Jia; Xu, Liang-Yu; Huang, Rui-Hong; Lin, Pei-Xian; Chen, Jian-Zhou; Li, De-Rui; Chen, Chuang-Zhen

    2017-01-01

    To compare the radiobiological response between simultaneously dose-escalated and non-escalated intensity-modulated radiation therapy (DE-IMRT and NE-IMRT) for patients with upper thoracic esophageal cancer (UTEC) using radiobiological evaluation. Computed tomography simulation data sets for 25 patients pathologically diagnosed with primary UTEC were used in this study. DE-IMRT plan with an escalated dose of 64.8 Gy/28 fractions to the gross tumor volume (GTV) and involved lymph nodes from 25 patients pathologically diagnosed with primary UTEC, was compared to an NE-IMRT plan of 50.4 Gy/28 fractions. Dose-volume metrics, tumor control probability (TCP), and normal tissue complication probability for the lung and spinal cord were compared. In addition, the risk of acute esophageal toxicity (AET) and late esophageal toxicity (LET) were also analyzed. Compared with NE-IMRT plan, we found the DE-IMRT plan resulted in a 14.6 Gy dose escalation to the GTV. The tumor control was predicted to increase by 31.8%, 39.1%, and 40.9% for three independent TCP models. The predicted incidence of radiation pneumonitis was similar (3.9% versus 3.6%), and the estimated risk of radiation-induced spinal cord injury was extremely low (<0.13%) in both groups. Regarding the esophageal toxicities, the estimated grade ≥2 and grade ≥3 AET predicted by the Kwint model were increased by 2.5% and 3.8%. Grade ≥2 AET predicted using the Wijsman model was increased by 14.9%. The predicted incidence of LET was low (<0.51%) in both groups. Radiobiological evaluation reveals that the DE-IMRT dosing strategy is feasible for patients with UTEC, with significant gains in tumor control and minor or clinically acceptable increases in radiation-induced toxicities.

  3. Can authorities appreciably enhance the prescribing of oral generic risperidone to conserve resources? Findings from across Europe and their implications.

    PubMed

    Godman, Brian; Petzold, Max; Bennett, Kathleen; Bennie, Marion; Bucsics, Anna; Finlayson, Alexander E; Martin, Andrew; Persson, Marie; Piessnegger, Jutta; Raschi, Emanuel; Simoens, Steven; Zara, Corinne; Barbui, Corrado

    2014-06-13

    Generic atypical antipsychotic drugs offer health authorities opportunities for considerable savings. However, schizophrenia and bipolar disorders are complex diseases that require tailored treatments. Consequently, generally there have been limited demand-side measures by health authorities to encourage the preferential prescribing of generics. This is unlike the situation with hypertension, hypercholaesterolaemia or acid-related stomach disorders.The objectives of this study were to compare the effect of the limited demand-side measures in Western European countries and regions on the subsequent prescribing of risperidone following generics; to utilise the findings to provide future guidance to health authorities; and where possible, to investigate the utilisation of generic versus originator risperidone and the prices for generic risperidone. Principally, this was a segmented regression analysis of retrospective time-series data of the effect of the various initiatives in Belgium, Ireland, Scotland and Sweden following the introduction of generic risperidone. The study included patients prescribed at least one atypical antipsychotic drug up to 20 months before and up to 20 months after generic risperidone. In addition, retrospective observational studies were carried out in Austria and Spain (Catalonia) from 2005 to 2011 as well as one English primary care organisation (Bury Primary Care Trust (PCT)). There was a consistent steady reduction in risperidone as a percentage of total selected atypical antipsychotic utilisation following generics. A similar pattern was seen in Austria and Spain, with stable utilisation in one English PCT. However, there was considerable variation in the utilisation of generic risperidone, ranging from 98% of total risperidone in Scotland to only 14% in Ireland. Similarly, the price of generic risperidone varied considerably. In Scotland, generic risperidone was only 16% of pre-patent loss prices versus 72% in Ireland. Consistent findings of no increased prescribing of risperidone post generics with limited specific demand-side measures suggests no 'spillover' effect from one class to another encouraging the preferential prescribing of generic atypical antipsychotic drugs. This is exacerbated by the complexity of the disease area and differences in the side-effects between treatments. There appeared to be no clinical issues with generic risperidone, and prices inversely reflected measures to enhance their utilisation.

  4. Acquisition and utilisation of anthropometric measurements on admission in a paediatric hospital before and after the introduction of a malnutrition screening tool.

    PubMed

    Milani, S; Wright, C; Purcell, O; Macleod, I; Gerasimidis, K

    2013-06-01

    Acquisition of anthropometric measurements and assessment of growth in paediatric inpatients remains poor. The introduction of malnutrition screening tools that incorporate weight and height/length measurements might improve their acquisition and utilisation in other aspects of patient care. Documentation of weight and/length measurements and their plotting on growth charts was evaluated using a case notes review in paediatric inpatients who were admitted before (n = 146), during (n = 154) and after the pilot (n = 151) and official (n = 128) clinical use of a screening tool. Documentation of weight was high in all periods (> 97% of patients). Height/length measurement documentation was negligible (4% of patients) but improved after the introduction of the screening tool (> 62%; P < 0.0001), except in infants, who were not part of the screening programme. Introduction of a screening tool improved the acquisition of anthropometric measurements by nursing staff, although its utilisation by medical staff remained poor. © 2013 The Authors Journal of Human Nutrition and Dietetics © 2013 The British Dietetic Association Ltd.

  5. Design of a radiation facility for very small specimens used in radiobiology studies

    NASA Astrophysics Data System (ADS)

    Rodriguez, Manuel; Jeraj, Robert

    2008-06-01

    A design of a radiation facility for very small specimens used in radiobiology is presented. This micro-irradiator has been primarily designed to irradiate partial bodies in zebrafish embryos 3-4 mm in length. A miniature x-ray, 50 kV photon beam, is used as a radiation source. The source is inserted in a cylindrical brass collimator that has a pinhole of 1.0 mm in diameter along the central axis to produce a pencil photon beam. The collimator with the source is attached underneath a computer-controlled movable table which holds the specimens. Using a 45° tilted mirror, a digital camera, connected to the computer, takes pictures of the specimen and the pinhole collimator. From the image provided by the camera, the relative distance from the specimen to the pinhole axis is calculated and coordinates are sent to the movable table to properly position the samples in the beam path. Due to its monitoring system, characteristic of the radiation beam, accuracy and precision of specimen positioning, and automatic image-based specimen recognition, this radiation facility is a suitable tool to irradiate partial bodies in zebrafish embryos, cell cultures or any other small specimen used in radiobiology research.

  6. Targeted alpha therapy using Radium-223: From physics to biological effects.

    PubMed

    Marques, I A; Neves, A R; Abrantes, A M; Pires, A S; Tavares-da-Silva, E; Figueiredo, A; Botelho, M F

    2018-05-25

    With the advance of the use of ionizing radiation in therapy, targeted alpha therapy (TAT) has assumed an important role around the world. This kind of therapy can potentially reduce side effects caused by radiation in normal tissues and increased destructive radiobiological effects in tumor cells. However, in many countries, the use of this therapy is still in a pioneering phase. Radium-223 ( 223 Ra), an alpha-emitting radionuclide, has been the first of its kind to be approved for the treatment of bone metastasis in metastatic castration-resistant prostate cancer. Nevertheless, the interaction mechanism and the direct effects of this radiopharmaceutical in tumor cells are not fully understood neither characterized at a molecular level. In fact, the ways how TAT is linked to radiobiological effects in cancer is not yet revised. Therefore, this review introduces some physical properties of TAT that leads to biological effects and links this information to the hallmarks of cancer. The authors also collected the studies developed with 223 Ra to correlate with the three categories reviewed - properties of TAT, 5 R's of radiobiology and hallmarks of cancer- and with the promising future to this radiopharmaceutical. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. Bringing the heavy: carbon ion therapy in the radiobiological and clinical context

    PubMed Central

    2014-01-01

    Radiotherapy for the treatment of cancer is undergoing an evolution, shifting to the use of heavier ion species. For a plethora of malignancies, current radiotherapy using photons or protons yields marginal benefits in local control and survival. One hypothesis is that these malignancies have acquired, or are inherently radioresistant to low LET radiation. In the last decade, carbon ion radiotherapy facilities have slowly been constructed in Europe and Asia, demonstrating favorable results for many of the malignancies that do poorly with conventional radiotherapy. However, from a radiobiological perspective, much of how this modality works in overcoming radioresistance, and extending local control and survival are not yet fully understood. In this review, we will explain from a radiobiological perspective how carbon ion radiotherapy can overcome the classical and recently postulated contributors of radioresistance (α/β ratio, hypoxia, cell proliferation, the tumor microenvironment and metabolism, and cancer stem cells). Furthermore, we will make recommendations on the important factors to consider, such as anatomical location, in the future design and implementation of clinical trials. With the existing data available we believe that the expansion of carbon ion facilities into the United States is warranted. PMID:24679134

  8. Treatment plan comparison between helical tomotherapy and MLC-based IMRT using radiobiological measures

    NASA Astrophysics Data System (ADS)

    Mavroidis, Panayiotis; Costa Ferreira, Brigida; Shi, Chengyu; Lind, Bengt K.; Papanikolaou, Nikos

    2007-07-01

    The rapid implementation of advanced treatment planning and delivery technologies for radiation therapy has brought new challenges in evaluating the most effective treatment modality. Intensity-modulated radiotherapy (IMRT) using multi-leaf collimators (MLC) and helical tomotherapy (HT) are becoming popular modes of treatment delivery and their application and effectiveness continues to be investigated. Presently, there are several treatment planning systems (TPS) that can generate and optimize IMRT plans based on user-defined objective functions for the internal target volume (ITV) and organs at risk (OAR). However, the radiobiological parameters of the different tumours and normal tissues are typically not taken into account during dose prescription and optimization of a treatment plan or during plan evaluation. The suitability of a treatment plan is typically decided based on dosimetric criteria such as dose-volume histograms (DVH), maximum, minimum, mean and standard deviation of the dose distribution. For a more comprehensive treatment plan evaluation, the biologically effective uniform dose ({\\bar{\\bar{D}}}) is applied together with the complication-free tumour control probability (P+). Its utilization is demonstrated using three clinical cases that were planned with two different forms of IMRT. In this study, three different cancer types at different anatomical sites were investigated: head and neck, lung and prostate cancers. For each cancer type, a linac MLC-based step-and-shoot IMRT plan and a HT plan were developed. The MLC-based IMRT treatment plans were developed on the Philips treatment-planning platform, using the Pinnacle 7.6 software release. For the tomotherapy HiArt plans, the dedicated tomotherapy treatment planning station was used, running version 2.1.2. By using {\\bar{\\bar{D}}} as the common prescription point of the treatment plans and plotting the tissue response probabilities versus {\\bar{\\bar{D}}} for a range of prescription doses, a number of plan trials can be compared based on radiobiological measures. The applied plan evaluation method shows that in the head and neck cancer case the HT treatment gives better results than MLC-based IMRT in terms of expected clinical outcome (P+ of 62.2% and 46.0%, {\\bar{\\bar{D}}} to the ITV of 72.3 Gy and 70.7 Gy, respectively). In the lung cancer and prostate cancer cases, the MLC-based IMRT plans are better over the clinically useful dose prescription range. For the lung cancer case, the HT and MLC-based IMRT plans give a P+ of 66.9% and 72.9%, {\\bar{\\bar{D}}} to the ITV of 64.0 Gy and 66.9 Gy, respectively. Similarly, for the prostate cancer case, the two radiation modalities give a P+ of 68.7% and 72.2%, {\\bar{\\bar{D}}} to the ITV of 86.0 Gy and 85.9 Gy, respectively. If a higher risk of complications (higher than 5%) could be allowed, the complication-free tumour control could increase by over 40%, 2% and 30% compared to the initial dose prescription for the three cancer cases, respectively. Both MLC-based IMRT and HT can encompass the often-large ITV required while they minimize the volume of the organs at risk receiving high doses. Radiobiological evaluation of treatment plans may provide an improved correlation of the delivered treatment with the clinical outcome by taking into account the dose-response characteristics of the irradiated targets and normal tissues. There may exist clinical cases, which may look dosimetrically similar but in radiobiological terms may be quite different. In such situations, traditional dose-based evaluation tools can be complemented by the use of P_ +{-}{\\bar{\\bar{D}}} diagrams to effectively evaluate and compare treatment plans.

  9. MO-D-BRD-01: Clinical Implementation of An Electronic Brachytherapy Program for the Skin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ouhib, Z.

    2015-06-15

    Electronic brachytherapy (eBT) has seen an insurgence of manufacturers entering the US market for use in radiation therapy. In addition to the established interstitial, intraluminary, and intracavitary applications of eBT, many centers are now using eBT to treat skin lesions. It is important for medical physicists working with electronic brachytherapy sources to understand the basic physics principles of the sources themselves as well as the variety of applications for which they are being used. The calibration of the sources is different from vendor to vendor and the traceability of calibrations has evolved as new sources came to market. In 2014,more » a new air-kerma based standard was introduced by the National Institute of Standards and Technology (NIST) to measure the output of an eBT source. Eventually commercial treatment planning systems should accommodate this new standard and provide NIST traceability to the end user. The calibration and commissioning of an eBT system is unique to its application and typically entails a list of procedural recommendations by the manufacturer. Commissioning measurements are performed using a variety of methods, some of which are modifications of existing AAPM Task Group protocols. A medical physicist should be familiar with the different AAPM Task Group recommendations for applicability to eBT and how to properly adapt them to their needs. In addition to the physical characteristics of an eBT source, the photon energy is substantially lower than from HDR Ir-192 sources. Consequently, tissue-specific dosimetry and radiobiological considerations are necessary when comparing these brachytherapy modalities and when making clinical decisions as a radiation therapy team. In this session, the physical characteristics and calibration methodologies of eBt sources will be presented as well as radiobiology considerations and other important clinical considerations. Learning Objectives: To understand the basic principles of electronic brachytherapy and the various applications for which it is being used. To understand the physics of the calibration and commissioning for electronic brachytherapy sources To understand the unique radiobiology and clinical implementation of electronic brachytherapy systems for skin and IORT techniques Xoft, Inc. contributed funding toward development of the NIST electronic brachytherapy facility (Michael Mitch).The University of Wisconsin (Wesley Culberson) has received research support funding from Xoft, Inc. Zoubir Ouhib has received partial funding from Elekta Esteya.« less

  10. WE-AB-202-11: Radiobiological Modeling of Tumor Response During Radiotherapy Based On Pre-Treatment Dynamic PET Imaging Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crispin-Ortuzar, M; Grkovski, M; Beattie, B

    Purpose: To evaluate the ability of a multiscale radiobiological model of tumor response to predict mid-treatment hypoxia images, based on pretreatment imaging of perfusion and hypoxia with [18-F]FMISO dynamic PET and glucose metabolism with [18-F]FDG PET. Methods: A mechanistic tumor control probability (TCP) radiobiological model describing the interplay between tumor cell proliferation and hypoxia (Jeong et al., PMB 2013) was extended to account for intra-tumor nutrient heterogeneity, dynamic cell migration due to nutrient gradients, and stromal cells. This extended model was tested on 10 head and neck cancer patients treated with chemoradiotherapy, randomly drawn from a larger MSKCC protocol involvingmore » baseline and mid-therapy dynamic PET scans. For each voxel, initial fractions of proliferative and hypoxic tumor cells were obtained by finding an approximate solution to a system of linear equations relating cell fractions to voxel-level FDG uptake, perfusion (FMISO K{sub 1}) and hypoxia (FMISO k{sub 3}). The TCP model then predicted their evolution over time up until the mid treatment scan. Finally, the linear model was reapplied to predict each lesion’s median hypoxia level (k{sub 3}[med,sim]) which in turn was compared to the FMISO k{sub 3}[med] measured at mid-therapy. Results: The average k3[med] of the tumors in pre-treatment scans was 0.0035 min{sup −1}, with an inter-tumor standard deviation of σ[pre]=0.0034 min{sup −1}. The initial simulated k{sub 3}[med,sim] of each tumor agreed with the corresponding measurements within 0.1σ[pre]. In 7 out of 10 lesions, the mid-treatment k{sub 3}[med,sim] prediction agreed with the data within 0.3σ[pre]. The remaining cases corresponded to the most extreme relative changes in k{sub 3}[med]. Conclusion: This work presents a method to personalize the prediction of a TCP model using pre-treatment kinetic imaging data, and validates the modeling of radiotherapy response by predicting changes in median hypoxia values during treatment. Variations from predicted response may be a useful biomarker, which should be further explored. Partially supported by NIH grant #1 R01 CA157770-01A1 and a grant from Varian Corporation.« less

  11. MO-D-BRD-04: NIST Air-Kerma Standard for Electronic Brachytherapy Calibrations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mitch, M.

    Electronic brachytherapy (eBT) has seen an insurgence of manufacturers entering the US market for use in radiation therapy. In addition to the established interstitial, intraluminary, and intracavitary applications of eBT, many centers are now using eBT to treat skin lesions. It is important for medical physicists working with electronic brachytherapy sources to understand the basic physics principles of the sources themselves as well as the variety of applications for which they are being used. The calibration of the sources is different from vendor to vendor and the traceability of calibrations has evolved as new sources came to market. In 2014,more » a new air-kerma based standard was introduced by the National Institute of Standards and Technology (NIST) to measure the output of an eBT source. Eventually commercial treatment planning systems should accommodate this new standard and provide NIST traceability to the end user. The calibration and commissioning of an eBT system is unique to its application and typically entails a list of procedural recommendations by the manufacturer. Commissioning measurements are performed using a variety of methods, some of which are modifications of existing AAPM Task Group protocols. A medical physicist should be familiar with the different AAPM Task Group recommendations for applicability to eBT and how to properly adapt them to their needs. In addition to the physical characteristics of an eBT source, the photon energy is substantially lower than from HDR Ir-192 sources. Consequently, tissue-specific dosimetry and radiobiological considerations are necessary when comparing these brachytherapy modalities and when making clinical decisions as a radiation therapy team. In this session, the physical characteristics and calibration methodologies of eBt sources will be presented as well as radiobiology considerations and other important clinical considerations. Learning Objectives: To understand the basic principles of electronic brachytherapy and the various applications for which it is being used. To understand the physics of the calibration and commissioning for electronic brachytherapy sources To understand the unique radiobiology and clinical implementation of electronic brachytherapy systems for skin and IORT techniques Xoft, Inc. contributed funding toward development of the NIST electronic brachytherapy facility (Michael Mitch).The University of Wisconsin (Wesley Culberson) has received research support funding from Xoft, Inc. Zoubir Ouhib has received partial funding from Elekta Esteya.« less

  12. MO-D-BRD-00: Electronic Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Electronic brachytherapy (eBT) has seen an insurgence of manufacturers entering the US market for use in radiation therapy. In addition to the established interstitial, intraluminary, and intracavitary applications of eBT, many centers are now using eBT to treat skin lesions. It is important for medical physicists working with electronic brachytherapy sources to understand the basic physics principles of the sources themselves as well as the variety of applications for which they are being used. The calibration of the sources is different from vendor to vendor and the traceability of calibrations has evolved as new sources came to market. In 2014,more » a new air-kerma based standard was introduced by the National Institute of Standards and Technology (NIST) to measure the output of an eBT source. Eventually commercial treatment planning systems should accommodate this new standard and provide NIST traceability to the end user. The calibration and commissioning of an eBT system is unique to its application and typically entails a list of procedural recommendations by the manufacturer. Commissioning measurements are performed using a variety of methods, some of which are modifications of existing AAPM Task Group protocols. A medical physicist should be familiar with the different AAPM Task Group recommendations for applicability to eBT and how to properly adapt them to their needs. In addition to the physical characteristics of an eBT source, the photon energy is substantially lower than from HDR Ir-192 sources. Consequently, tissue-specific dosimetry and radiobiological considerations are necessary when comparing these brachytherapy modalities and when making clinical decisions as a radiation therapy team. In this session, the physical characteristics and calibration methodologies of eBt sources will be presented as well as radiobiology considerations and other important clinical considerations. Learning Objectives: To understand the basic principles of electronic brachytherapy and the various applications for which it is being used. To understand the physics of the calibration and commissioning for electronic brachytherapy sources To understand the unique radiobiology and clinical implementation of electronic brachytherapy systems for skin and IORT techniques Xoft, Inc. contributed funding toward development of the NIST electronic brachytherapy facility (Michael Mitch).The University of Wisconsin (Wesley Culberson) has received research support funding from Xoft, Inc. Zoubir Ouhib has received partial funding from Elekta Esteya.« less

  13. MO-D-BRD-02: Radiological Physics and Surface Lesion Treatments with Electronic Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fulkerson, R.

    Electronic brachytherapy (eBT) has seen an insurgence of manufacturers entering the US market for use in radiation therapy. In addition to the established interstitial, intraluminary, and intracavitary applications of eBT, many centers are now using eBT to treat skin lesions. It is important for medical physicists working with electronic brachytherapy sources to understand the basic physics principles of the sources themselves as well as the variety of applications for which they are being used. The calibration of the sources is different from vendor to vendor and the traceability of calibrations has evolved as new sources came to market. In 2014,more » a new air-kerma based standard was introduced by the National Institute of Standards and Technology (NIST) to measure the output of an eBT source. Eventually commercial treatment planning systems should accommodate this new standard and provide NIST traceability to the end user. The calibration and commissioning of an eBT system is unique to its application and typically entails a list of procedural recommendations by the manufacturer. Commissioning measurements are performed using a variety of methods, some of which are modifications of existing AAPM Task Group protocols. A medical physicist should be familiar with the different AAPM Task Group recommendations for applicability to eBT and how to properly adapt them to their needs. In addition to the physical characteristics of an eBT source, the photon energy is substantially lower than from HDR Ir-192 sources. Consequently, tissue-specific dosimetry and radiobiological considerations are necessary when comparing these brachytherapy modalities and when making clinical decisions as a radiation therapy team. In this session, the physical characteristics and calibration methodologies of eBt sources will be presented as well as radiobiology considerations and other important clinical considerations. Learning Objectives: To understand the basic principles of electronic brachytherapy and the various applications for which it is being used. To understand the physics of the calibration and commissioning for electronic brachytherapy sources To understand the unique radiobiology and clinical implementation of electronic brachytherapy systems for skin and IORT techniques Xoft, Inc. contributed funding toward development of the NIST electronic brachytherapy facility (Michael Mitch).The University of Wisconsin (Wesley Culberson) has received research support funding from Xoft, Inc. Zoubir Ouhib has received partial funding from Elekta Esteya.« less

  14. Measuring change in health care equity using small-area administrative data - evidence from the English NHS 2001-2008.

    PubMed

    Cookson, Richard; Laudicella, Mauro; Donni, Paolo Li

    2012-10-01

    This study developed a method for measuring change in socio-economic equity in health care utilisation using small-area level administrative data. Our method provides more detailed information on utilisation than survey data but only examines socio-economic differences between neighbourhoods rather than individuals. The context was the English NHS from 2001 to 2008, a period of accelerated expenditure growth and pro-competition reform. Hospital records for all adults receiving non-emergency hospital care in the English NHS from 2001 to 2008 were aggregated to 32,482 English small areas with mean population about 1500 and combined with other small-area administrative data. Regression models of utilisation were used to examine year-on-year change in the small-area association between deprivation and utilisation, allowing for population size, age-sex composition and disease prevalence including (from 2003 to 2008) cancer, chronic kidney disease, coronary heart disease, diabetes, epilepsy, hypertension, hypothyroidism, stroke, transient ischaemic attack and (from 2006 to 2008) atrial fibrillation, chronic obstructive pulmonary disease, obesity and heart failure. There was no substantial change in small-area associations between deprivation and utilisation for outpatient visits, hip replacement, senile cataract, gastroscopy or coronary revascularisation, though overall non-emergency inpatient admissions rose slightly faster in more deprived areas than elsewhere. Associations between deprivation and disease prevalence changed little during the period, indicating that observed need did not grow faster in more deprived areas than elsewhere. We conclude that there was no substantial deterioration in socio-economic equity in health care utilisation in the English NHS from 2001 to 2008, and if anything, there may have been a slight improvement. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. AFRRI (Armed Forces Radiobiology Research Institute) Reports, July, August and September 1986

    DTIC Science & Technology

    1986-09-01

    detectors (LiF TLD 100s) on a cat phantom. The dosimetry indicated that the shoulders of the cat received an exposure of 4.6% of the total dose, while...radiographically determined outline of the precordium, and dosimetry measurements were made on one of the experimental animals. Isodose curves (Fig. 1) were...of 0.01-25 Gy/min and bi- lateral dose rates of 0.08-57 Gy/min can be ad- ministered with error bounds of ±5%. Dosimetry was done using tissue

  16. DNA damage induction and/or repair as mammalian cell biomarker for the prediction of cellular radiation response

    NASA Astrophysics Data System (ADS)

    Baumstark-Khan, C.

    DNA damage and its repair processes are key factors in cancer induction and also in the treatment of malignancies. Cancer prevention during extended space missions becomes a topic of great importance for space radiobiology. The knowledge of individual responsiveness would allow the protection strategy to be tailored optimally in each case. Radiobiological analysis of cultured cells derived from tissue explants from individuals has shown that measurement of the surviving fraction after 2 Gy (SF2) may be used to predict the individual responsiveness. However, clonogenic assays are timeconsuming, thus alternative assays for the determination of radiore-sponse are being sought. For that reason CHO cell strains having different repair capacities were used for examining whether DNA strand break repair is a suitable experimental design to allow predictive statements. Cellular survival (CFA assay) and DNA strand breaks (total DNA strand breaks: FADU technique; DSBs: non-denaturing elution) were determined in parallel immediately after irradiation as well as after a 24 hour recovery period according to dose. There were no correlations between the dose-response curves of the initial level of DNA strand breaks and parameters that describe clonogenic survival curves (SF2). A good correlation exists between intrinsic cellular radioresistance and the extent of residual DNA strand breaks.

  17. An interlaboratory comparison of dosimetry for a multi-institutional radiobiological research project: Observations, problems, solutions and lessons learned.

    PubMed

    Seed, Thomas M; Xiao, Shiyun; Manley, Nancy; Nikolich-Zugich, Janko; Pugh, Jason; Van den Brink, Marcel; Hirabayashi, Yoko; Yasutomo, Koji; Iwama, Atsushi; Koyasu, Shigeo; Shterev, Ivo; Sempowski, Gregory; Macchiarini, Francesca; Nakachi, Kei; Kunugi, Keith C; Hammer, Clifford G; Dewerd, Lawrence A

    2016-01-01

    An interlaboratory comparison of radiation dosimetry was conducted to determine the accuracy of doses being used experimentally for animal exposures within a large multi-institutional research project. The background and approach to this effort are described and discussed in terms of basic findings, problems and solutions. Dosimetry tests were carried out utilizing optically stimulated luminescence (OSL) dosimeters embedded midline into mouse carcasses and thermal luminescence dosimeters (TLD) embedded midline into acrylic phantoms. The effort demonstrated that the majority (4/7) of the laboratories was able to deliver sufficiently accurate exposures having maximum dosing errors of ≤5%. Comparable rates of 'dosimetric compliance' were noted between OSL- and TLD-based tests. Data analysis showed a highly linear relationship between 'measured' and 'target' doses, with errors falling largely between 0 and 20%. Outliers were most notable for OSL-based tests, while multiple tests by 'non-compliant' laboratories using orthovoltage X-rays contributed heavily to the wide variation in dosing errors. For the dosimetrically non-compliant laboratories, the relatively high rates of dosing errors were problematic, potentially compromising the quality of ongoing radiobiological research. This dosimetry effort proved to be instructive in establishing rigorous reviews of basic dosimetry protocols ensuring that dosing errors were minimized.

  18. MO-FG-BRA-05: Dosimetric and Radiobiological Validation of Respiratory Gating in Conventional and Hypofractionated Radiotherapy of the Lung: Effect of Dose, Dose Rate, Gating Window and Breathing Pattern

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cervino, L; Soultan, D; Pettersson, N

    2016-06-15

    Purpose: to evaluate the dosimetric and radiobiological consequences from having different gating windows, dose rates, and breathing patterns in gated VMAT lung radiotherapy. Methods: A novel 3D-printed moving phantom with central high and peripheral low tracer uptake regions was 4D FDG-PET/CT-scanned using ideal, patient-specific regular, and irregular breathing patterns. A scan of the stationary phantom was obtained as a reference. Target volumes corresponding to different uptake regions were delineated. Simultaneous integrated boost (SIB) 6 MV VMAT plans were produced for conventional and hypofractionated radiotherapy, using 30–70 and 100% cycle gating scenarios. Prescribed doses were 200 cGy with SIB to 240more » cGy to high uptake volume for conventional, and 800 with SIB to 900 cGy for hypofractionated plans. Dose rates of 600 MU/min (conventional and hypofractionated) and flattening filter free 1400 MU/min (hypofractionated) were used. Ion chamber measurements were performed to verify delivered doses. Vials with A549 cells placed in locations matching ion chamber measurements were irradiated using the same plans to measure clonogenic survival. Differences in survival for the different doses, dose rates, gating windows, and breathing patterns were analyzed. Results: Ion chamber measurements agreed within 3% of the planned dose, for all locations, breathing patterns and gating windows. Cell survival depended on dose alone, and not on gating window, breathing pattern, MU rate, or delivery time. The surviving fraction varied from approximately 40% at 2Gy to 1% for 9 Gy and was within statistical uncertainty relative to that observed for the stationary phantom. Conclusions: Use of gated VMAT in PET-driven SIB radiotherapy was validated using ion chamber measurements and cell survival assays for conventional and hypofractionated radiotherapy.« less

  19. Developing and Testing a New Measurement Instrument for Documenting Instrumental Knowledge Utilisation: The Degrees of Knowledge Utilization (DoKU) Scale

    ERIC Educational Resources Information Center

    Bøllingtoft Knudsen, Søren

    2018-01-01

    Focus on evidence-based policymaking is greater than ever, and public spending on evaluations is rising. A primary merit of these expenditures is that politicians actually use new knowledge instrumentally--to influence and inform decision making. Nevertheless, we know surprisingly little about whether and how research-based knowledge is utilised.…

  20. On the new metrics for IMRT QA verification.

    PubMed

    Garcia-Romero, Alejandro; Hernandez-Vitoria, Araceli; Millan-Cebrian, Esther; Alba-Escorihuela, Veronica; Serrano-Zabaleta, Sonia; Ortega-Pardina, Pablo

    2016-11-01

    The aim of this work is to search for new metrics that could give more reliable acceptance/rejection criteria on the IMRT verification process and to offer solutions to the discrepancies found among different conventional metrics. Therefore, besides conventional metrics, new ones are proposed and evaluated with new tools to find correlations among them. These new metrics are based on the processing of the dose-volume histogram information, evaluating the absorbed dose differences, the dose constraint fulfillment, or modified biomathematical treatment outcome models such as tumor control probability (TCP) and normal tissue complication probability (NTCP). An additional purpose is to establish whether the new metrics yield the same acceptance/rejection plan distribution as the conventional ones. Fifty eight treatment plans concerning several patient locations are analyzed. All of them were verified prior to the treatment, using conventional metrics, and retrospectively after the treatment with the new metrics. These new metrics include the definition of three continuous functions, based on dose-volume histograms resulting from measurements evaluated with a reconstructed dose system and also with a Monte Carlo redundant calculation. The 3D gamma function for every volume of interest is also calculated. The information is also processed to obtain ΔTCP or ΔNTCP for the considered volumes of interest. These biomathematical treatment outcome models have been modified to increase their sensitivity to dose changes. A robustness index from a radiobiological point of view is defined to classify plans in robustness against dose changes. Dose difference metrics can be condensed in a single parameter: the dose difference global function, with an optimal cutoff that can be determined from a receiver operating characteristics (ROC) analysis of the metric. It is not always possible to correlate differences in biomathematical treatment outcome models with dose difference metrics. This is due to the fact that the dose constraint is often far from the dose that has an actual impact on the radiobiological model, and therefore, biomathematical treatment outcome models are insensitive to big dose differences between the verification system and the treatment planning system. As an alternative, the use of modified radiobiological models which provides a better correlation is proposed. In any case, it is better to choose robust plans from a radiobiological point of view. The robustness index defined in this work is a good predictor of the plan rejection probability according to metrics derived from modified radiobiological models. The global 3D gamma-based metric calculated for each plan volume shows a good correlation with the dose difference metrics and presents a good performance in the acceptance/rejection process. Some discrepancies have been found in dose reconstruction depending on the algorithm employed. Significant and unavoidable discrepancies were found between the conventional metrics and the new ones. The dose difference global function and the 3D gamma for each plan volume are good classifiers regarding dose difference metrics. ROC analysis is useful to evaluate the predictive power of the new metrics. The correlation between biomathematical treatment outcome models and the dose difference-based metrics is enhanced by using modified TCP and NTCP functions that take into account the dose constraints for each plan. The robustness index is useful to evaluate if a plan is likely to be rejected. Conventional verification should be replaced by the new metrics, which are clinically more relevant.

  1. Radioecology, radiobiology, and radiological protection: frameworks and fractures.

    PubMed

    Pentreath, R J

    2009-12-01

    A framework for the protection of the general public has been in existence for a very long time, although steps have recently been made by the ICRP to ensure that it is more fully comprehensive with regard to all actual and potential exposure situations. Protection of the environment, however, has only recently begun to be addressed in a structured manner, and is still an evolving subject. Nevertheless, it needs to be centred around some form of parallel framework to that which has evolved for the protection of human beings, although clearly on a different scale. It also needs to be embedded within the basic science of radiobiology, and form a central part of radioecology.

  2. BNL accelerator-based radiobiology facilities

    NASA Technical Reports Server (NTRS)

    Lowenstein, D. I.

    2001-01-01

    For the past several years, the Alternating Gradient Synchrotron (AGS) at Brookhaven National Laboratory (USA) has provided ions of iron, silicon and gold, at energies from 600 MeV/nucleon to 10 GeV/nucleon, for the US National Aeronautics and Space Administration (NASA) radiobiology research program. NASA has recently funded the construction of a new dedicated ion facility, the Booster Applications Facility (BAF). The Booster synchrotron will supply ion beams ranging from protons to gold, in an energy range from 40-3000 MeV/nucleon with maximum beam intensities of 10(10) to 10(11) ions per pulse. The BAF Project will be described and the future AGS and BAF operation plans will be presented.

  3. BNL accelerator-based radiobiology facilities.

    PubMed

    Lowenstein, D I

    2001-01-01

    For the past several years, the Alternating Gradient Synchrotron (AGS) at Brookhaven National Laboratory (USA) has provided ions of iron, silicon and gold, at energies from 600 MeV/nucleon to 10 GeV/nucleon, for the US National Aeronautics and Space Administration (NASA) radiobiology research program. NASA has recently funded the construction of a new dedicated ion facility, the Booster Applications Facility (BAF). The Booster synchrotron will supply ion beams ranging from protons to gold, in an energy range from 40-3000 MeV/nucleon with maximum beam intensities of 10(10) to 10(11) ions per pulse. The BAF Project will be described and the future AGS and BAF operation plans will be presented.

  4. Gender differences in substrate utilisation during exercise.

    PubMed

    Ruby, B C; Robergs, R A

    1994-06-01

    The selection and utilisation of metabolic substrates during endurance exercise are regulated by a complex array of effectors. These factors include, but are not limited to, endurance training and cardiorespiratory fitness, exercise intensity and duration, muscle morphology and histology, hormonal factors and diet. Although the effects of these factors on substrate utilisation patterns are well understood, the variation in substrate utilisation during endurance exercise between males and females is not. Because of the extreme heterogeneity in exercise protocols and individuals studied, the differences in substrate utilisation between males and females remain somewhat inconclusive. Regardless of heterogeneity, if the results from studies are interpreted collectively, an apparent gender difference in the selection and metabolism of substrates can be seen in sedentary individuals. However, this difference between genders diminishes as the level of cardiorespiratory fitness is increased to that of highly trained individuals. During rest and lower intensity exercise, the preferential metabolism of lipid occurs with a concomitant sparing of muscle glycogen. However, as the intensity of exercise is increased, the relative contribution of carbohydrate also increases. The exercise intensity at which the shift from lipid to carbohydrate is determined and regulated by the previously mentioned factors. Because the intensity and duration of exercise play a predominant role, the variation in exercise protocols poses a methodological concern when interpreting previous research. When attempting to compare the metabolism of substrates during endurance exercise, appropriate selection and interpretation of measurement techniques are necessary. Measurement techniques include the nonprotein respiratory exchange ratio, muscle and fat biopsies and the measurement of various blood metabolites, such as free fatty acids and glycerol. Similarly, in vitro analysis of lipolytic activity has also been demonstrated in males and females in response to varying levels of female gonadotrophic hormones. When comparing the substrate utilisation patterns between males and females, the area of hormonal regulation has received less attention. Often the catecholamine response to endurance exercise is measured; however, the gonadotrophic hormones, particularly those of the female, have received less attention when comparing genders. Indeed, the regulatory nature of the female gonadotrophic hormones has been demonstrated. Collectively, the effects of elevated estrogen, as in the luteal phase of menstruation, appear to promote lipolytic activity. Estrogen-mediated lipolytic activation occurs by apparently altering the sensitivity to lipoprotein lipase and by increasing the levels of human growth hormone (somatotropin), an activator of lipolysis.(ABSTRACT TRUNCATED AT 400 WORDS)

  5. Inequalities in utilisation of general practitioner and specialist services in 9 European countries.

    PubMed

    Stirbu, Irina; Kunst, Anton E; Mielck, Andreas; Mackenbach, Johan P

    2011-10-31

    The aim of this study is to describe the magnitude of educational inequalities in utilisation of general practitioner (GP) and specialist services in 9 European countries. In addition to West European countries, we have included 3 Eastern European countries: Hungary, Estonia and Latvia. To cover the gap in knowledge we pay a special attention to the magnitude of inequalities among patients with chronic conditions. Data on the use of GP and specialist services were derived from national health surveys of Belgium, Estonia, France, Germany, Hungary, Ireland, Latvia, the Netherlands and Norway. For each country and education level we calculated the absolute prevalence and relative inequalities in utilisation of GP and specialist services. In order to account for the need for care, the results were adjusted by the measure of self-assessed health. People with lower education used GP services equally often in most countries (except Belgium and Germany) compared with those with a higher level of education. At the same time people with a higher education used specialist care services significantly more often in all countries, except in the Netherlands. The general pattern of educational inequalities in utilisation of specialist care was similar for both men and women. Inequalities in utilisation of specialist care were equally large in Eastern European and in Western European countries, except for Latvia where the inequalities were somewhat larger. Similarly, large inequalities were found in the utilisation of specialist care among patients with chronic diseases, diabetes, and hypertension. We found large inequalities in the utilisation of specialist care. These inequalities were not compensated by utilisation of GP services. Of particular concern is the presence of inequalities among patients with a high need for specialist care, such as those with chronic diseases. © 2011 Stirbu et al; licensee BioMed Central Ltd.

  6. Low LET protons focused to submicrometer shows enhanced radiobiological effectiveness

    NASA Astrophysics Data System (ADS)

    Schmid, T. E.; Greubel, C.; Hable, V.; Zlobinskaya, O.; Michalski, D.; Girst, S.; Siebenwirth, C.; Schmid, E.; Molls, M.; Multhoff, G.; Dollinger, G.

    2012-10-01

    This study shows that enhanced radiobiological effectiveness (RBE) values can be generated focusing low linear energy transfer (LET) radiation and thus changing the microdose distribution. 20 MeV protons (LET = 2.65 keV µm-1) are focused to submicrometer diameter at the ion microprobe superconducting nanoprobe for applied nuclear (Kern) physics experiments of the Munich tandem accelerator. The RBE values, as determined by measuring micronuclei (RBEMN = 1.48 ± 0.07) and dicentrics (RBED = 1.92 ± 0.15), in human-hamster hybrid (AL) cells are significantly higher when 117 protons were focused to a submicrometer irradiation field within a 5.4 × 5.4 µm2 matrix compared to quasi homogeneous in a 1 × 1 µm2 matrix applied protons (RBEMN = 1.28 ± 0.07; RBED = 1.41 ± 0.14) at the same average dose of 1.7 Gy. The RBE values are normalized to standard 70 kV (dicentrics) or 200 kV (micronuclei) x-ray irradiation. The 117 protons applied per point deposit the same amount of energy like a 12C ion with 55 MeV total energy (4.48 MeV u-1). The enhancements are about half of that obtained for 12C ions (RBEMN = 2.20 ± 0.06 and RBED = 3.21 ± 0.10) and they are attributed to intertrack interactions of the induced damages. The measured RBE values show differences from predictions of the local effect model (LEM III) that is used to calculate RBE values for irradiation plans to treat tumors with high LET particles.

  7. Low LET protons focused to submicrometer shows enhanced radiobiological effectiveness.

    PubMed

    Schmid, T E; Greubel, C; Hable, V; Zlobinskaya, O; Michalski, D; Girst, S; Siebenwirth, C; Schmid, E; Molls, M; Multhoff, G; Dollinger, G

    2012-10-07

    This study shows that enhanced radiobiological effectiveness (RBE) values can be generated focusing low linear energy transfer (LET) radiation and thus changing the microdose distribution. 20 MeV protons (LET = 2.65 keV µm(-1)) are focused to submicrometer diameter at the ion microprobe superconducting nanoprobe for applied nuclear (Kern) physics experiments of the Munich tandem accelerator. The RBE values, as determined by measuring micronuclei (RBE(MN) = 1.48 ± 0.07) and dicentrics (RBE(D) = 1.92 ± 0.15), in human-hamster hybrid (A(L)) cells are significantly higher when 117 protons were focused to a submicrometer irradiation field within a 5.4 × 5.4 µm(2) matrix compared to quasi homogeneous in a 1 × 1 µm(2) matrix applied protons (RBE(MN) = 1.28 ± 0.07; RBE(D) = 1.41 ± 0.14) at the same average dose of 1.7 Gy. The RBE values are normalized to standard 70 kV (dicentrics) or 200 kV (micronuclei) x-ray irradiation. The 117 protons applied per point deposit the same amount of energy like a (12)C ion with 55 MeV total energy (4.48 MeV u(-1)). The enhancements are about half of that obtained for (12)C ions (RBE(MN) = 2.20 ± 0.06 and RBE(D) = 3.21 ± 0.10) and they are attributed to intertrack interactions of the induced damages. The measured RBE values show differences from predictions of the local effect model (LEM III) that is used to calculate RBE values for irradiation plans to treat tumors with high LET particles.

  8. The radiobiology of laser-driven particle beams: focus on sub-lethal responses of normal human cells

    NASA Astrophysics Data System (ADS)

    Manti, L.; Perozziello, F. M.; Borghesi, M.; Candiano, G.; Chaudhary, P.; Cirrone, G. A. P.; Doria, D.; Gwynne, D.; Leanza, R.; Prise, K. M.; Romagnani, L.; Romano, F.; Scuderi, V.; Tramontana, A.

    2017-03-01

    Accelerated proton beams have become increasingly common for treating cancer. The need for cost and size reduction of particle accelerating machines has led to the pioneering investigation of optical ion acceleration techniques based on laser-plasma interactions as a possible alternative. Laser-matter interaction can produce extremely pulsed particle bursts of ultra-high dose rates (>= 109 Gy/s), largely exceeding those currently used in conventional proton therapy. Since biological effects of ionizing radiation are strongly affected by the spatio-temporal distribution of DNA-damaging events, the unprecedented physical features of such beams may modify cellular and tissue radiosensitivity to unexplored extents. Hence, clinical applications of laser-generated particles need thorough assessment of their radiobiological effectiveness. To date, the majority of studies have either used rodent cell lines or have focussed on cancer cell killing being local tumour control the main objective of radiotherapy. Conversely, very little data exist on sub-lethal cellular effects, of relevance to normal tissue integrity and secondary cancers, such as premature cellular senescence. Here, we discuss ultra-high dose rate radiobiology and present preliminary data obtained in normal human cells following irradiation by laser-accelerated protons at the LULI PICO2000 facility at Laser Lab Europe, France.

  9. In vivo radiobiological assessment of the new clinical carbon ion beams at CNAO.

    PubMed

    Facoetti, A; Vischioni, B; Ciocca, M; Ferrarini, M; Furusawa, Y; Mairani, A; Matsumoto, Y; Mirandola, A; Molinelli, S; Uzawa, A; Vilches, Freixas G; Orecchia, R

    2015-09-01

    In this article, the in vivo study performed to evaluate the uniformity of biological doses within an hypothetical target volume and calculate the values of relative biological effectiveness (RBE) at different depths in the spread-out Bragg peak (SOBP) of the new CNAO (National Centre for Oncological Hadrontherapy) carbon beams is presented, in the framework of a typical radiobiological beam calibration procedure. The RBE values (relative to (60)Co γ rays) of the CNAO active scanning carbon ion beams were determined using jejunal crypt regeneration in mice as biological system at the entrance, centre and distal end of a 6-cm SOBP. The RBE values calculated from the iso-effective doses to reduce crypt survival per circumference to 10, ranged from 1.52 at the middle of the SOBP to 1.75 at the distal position and are in agreement with those previously reported from other carbon ion facilities. In conclusion, this first set of in vivo experiments shows that the CNAO carbon beam is radiobiologically comparable with the NIRS (National Institute of Radiological Sciences, Chiba, Japan) and GSI (Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany) ones. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. Transformation of Physical DVHs to Radiobiologically Equivalent Ones in Hypofractionated Radiotherapy Analyzing Dosimetric and Clinical Parameters: A Practical Approach for Routine Clinical Practice in Radiation Oncology

    PubMed Central

    Thrapsanioti, Zoi; Karanasiou, Irene; Platoni, Kalliopi; Efstathopoulos, Efstathios P.; Matsopoulos, George; Dilvoi, Maria; Patatoukas, George; Chaldeopoulos, Demetrios; Kelekis, Nikolaos; Kouloulias, Vassilis

    2013-01-01

    Purpose. The purpose of this study was to transform DVHs from physical to radiobiological ones as well as to evaluate their reliability by correlations of dosimetric and clinical parameters for 50 patients with prostate cancer and 50 patients with breast cancer, who were submitted to Hypofractionated Radiotherapy. Methods and Materials. To achieve this transformation, we used both the linear-quadratic model (LQ model) and the Niemierko model. The outcome of radiobiological DVHs was correlated with acute toxicity score according to EORTC/RTOG criteria. Results. Concerning the prostate radiotherapy, there was a significant correlation between RTOG acute rectal toxicity and D 50 (P < 0.001) and V 60 (P = 0.001) dosimetric parameters, calculated for α/β = 10 Gy. Moreover, concerning the breast radiotherapy there was a significant correlation between RTOG skin toxicity and V ≥60 dosimetric parameter, calculated for both α/β = 2.3 Gy (P < 0.001) and α/β = 10 Gy (P < 0.001). The new tool seems reliable and user-friendly. Conclusions. Our proposed model seems user-friendly. Its reliability in terms of agreement with the presented acute radiation induced toxicity was satisfactory. However, more patients are needed to extract safe conclusions. PMID:24348743

  11. Spectral Performance of a Composite Single-Crystal Filtered Thermal Neutron Beam for BNCT Research at the University of Missouri

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. Brockman; D. W. Nigg; M. F. Hawthorne

    2009-07-01

    Parameter studies, design calculations and initial neutronic performance measurements have been completed for a new thermal neutron beamline to be used for neutron capture therapy cell and small-animal radiobiology studies at the University of Missouri Research Reactor. The beamline features the use of single-crystal silicon and bismuth sections for neutron filtering and for reduction of incident gamma radiation. The calculated and measured thermal neutron fluxes produced at the irradiation location are 9.6x108 and 8.8x108 neutrons/cm2-s, respectively. Calculated and measured cadmium ratios (Au foils) are 217 and 132. These results indicate a well-thermalized neutron spectrum with sufficient thermal neutron flux formore » a variety of small animal BNCT studies.« less

  12. Issues for Simulation of Galactic Cosmic Ray Exposures for Radiobiological Research at Ground-Based Accelerators

    PubMed Central

    Kim, Myung-Hee Y.; Rusek, Adam; Cucinotta, Francis A.

    2015-01-01

    For radiobiology research on the health risks of galactic cosmic rays (GCR) ground-based accelerators have been used with mono-energetic beams of single high charge, Z and energy, E (HZE) particles. In this paper, we consider the pros and cons of a GCR reference field at a particle accelerator. At the NASA Space Radiation Laboratory (NSRL), we have proposed a GCR simulator, which implements a new rapid switching mode and higher energy beam extraction to 1.5 GeV/u, in order to integrate multiple ions into a single simulation within hours or longer for chronic exposures. After considering the GCR environment and energy limitations of NSRL, we performed extensive simulation studies using the stochastic transport code, GERMcode (GCR Event Risk Model) to define a GCR reference field using 9 HZE particle beam–energy combinations each with a unique absorber thickness to provide fragmentation and 10 or more energies of proton and 4He beams. The reference field is shown to well represent the charge dependence of GCR dose in several energy bins behind shielding compared to a simulated GCR environment. However, a more significant challenge for space radiobiology research is to consider chronic GCR exposure of up to 3 years in relation to simulations with animal models of human risks. We discuss issues in approaches to map important biological time scales in experimental models using ground-based simulation, with extended exposure of up to a few weeks using chronic or fractionation exposures. A kinetics model of HZE particle hit probabilities suggests that experimental simulations of several weeks will be needed to avoid high fluence rate artifacts, which places limitations on the experiments to be performed. Ultimately risk estimates are limited by theoretical understanding, and focus on improving knowledge of mechanisms and development of experimental models to improve this understanding should remain the highest priority for space radiobiology research. PMID:26090339

  13. Three-Dimensional Radiobiologic Dosimetry: Application of Radiobiologic Modeling to Patient-Specific 3-Dimensional Imaging–Based Internal Dosimetry

    PubMed Central

    Prideaux, Andrew R.; Song, Hong; Hobbs, Robert F.; He, Bin; Frey, Eric C.; Ladenson, Paul W.; Wahl, Richard L.; Sgouros, George

    2010-01-01

    Phantom-based and patient-specific imaging-based dosimetry methodologies have traditionally yielded mean organ-absorbed doses or spatial dose distributions over tumors and normal organs. In this work, radiobiologic modeling is introduced to convert the spatial distribution of absorbed dose into biologically effective dose and equivalent uniform dose parameters. The methodology is illustrated using data from a thyroid cancer patient treated with radioiodine. Methods Three registered SPECT/CT scans were used to generate 3-dimensional images of radionuclide kinetics (clearance rate) and cumulated activity. The cumulated activity image and corresponding CT scan were provided as input into an EGSnrc-based Monte Carlo calculation: The cumulated activity image was used to define the distribution of decays, and an attenuation image derived from CT was used to define the corresponding spatial tissue density and composition distribution. The rate images were used to convert the spatial absorbed dose distribution to a biologically effective dose distribution, which was then used to estimate a single equivalent uniform dose for segmented volumes of interest. Equivalent uniform dose was also calculated from the absorbed dose distribution directly. Results We validate the method using simple models; compare the dose-volume histogram with a previously analyzed clinical case; and give the mean absorbed dose, mean biologically effective dose, and equivalent uniform dose for an illustrative case of a pediatric thyroid cancer patient with diffuse lung metastases. The mean absorbed dose, mean biologically effective dose, and equivalent uniform dose for the tumor were 57.7, 58.5, and 25.0 Gy, respectively. Corresponding values for normal lung tissue were 9.5, 9.8, and 8.3 Gy, respectively. Conclusion The analysis demonstrates the impact of radiobiologic modeling on response prediction. The 57% reduction in the equivalent dose value for the tumor reflects a high level of dose nonuniformity in the tumor and a corresponding reduced likelihood of achieving a tumor response. Such analyses are expected to be useful in treatment planning for radionuclide therapy. PMID:17504874

  14. Modification of radiobiological effects of 171 MeV protons by elements of physical protection

    NASA Astrophysics Data System (ADS)

    Bulinina, Taisia; Shurshakov, Vyacheslav; Ivanov, Alexander; Molokanov, Alexander

    2016-07-01

    Space radiation includes protons of various energies. Physical protection is effective in the case of low energy protons (50-100 MeV) and becomes insufficient for radiation with a high part of high-energy protons. In the experiment performed on outbred mice, the purpose of the study was to evaluate the radiobiological effect of 171 MeV protons and protons modified by elements of physical protection of the spacecraft, on a complex of indicators of the functional condition of the system hematopoiesis and the central nervous system in 24 hours after irradiation at 20 cGy dose. The spacecraft radiation protection elements used in the experiment were a construction of wet hygiene wipes called a «protective curtain», and a glass plate imitating an ISS window. Mass thickness of the " protective curtain" in terms of water equivalent was ̴ 6,2 g/cm2. Physical shielding along the path of 171 MeV protons increases their linear energy transfer leading to the absorbed dose elevation and strengthening of the radiobiological effect. In the experiment, the two types of shielding together raised the absorbed dose from 20 to 23.2 cGy. Chemically different materials (glass and water in the wipes) were found to exert unequal modifying effects on physical and biological parameters of the proton-irradiated mice. There was a distinct dose-dependent reduction of bone marrow cellularity within the dose range from 20 cGy to 23.2 cGy in 24 hours after exposure. No modifying effect of the radiation protection elements on spontaneous motor activity was discovered when compared with entrance protons. The group of animals protected by the glass plate exhibited normal orientative-trying reactions and weakened grip with the forelimbs. The effects observed in the experiment indicate the necessity to carry out comprehensive radiobiological researches (physical, biological and mathematical) in assessing the effects of physical protection, that are actual for ensuring radiation safety of crews in interplanetary flights.

  15. Radiobiological Determination of Dose Escalation and Normal Tissue Toxicity in Definitive Chemoradiation Therapy for Esophageal Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Warren, Samantha, E-mail: Samantha.warren@oncology.ox.ac.uk; Partridge, Mike; Carrington, Rhys

    2014-10-01

    Purpose: This study investigated the trade-off in tumor coverage and organ-at-risk sparing when applying dose escalation for concurrent chemoradiation therapy (CRT) of mid-esophageal cancer, using radiobiological modeling to estimate local control and normal tissue toxicity. Methods and Materials: Twenty-one patients with mid-esophageal cancer were selected from the SCOPE1 database (International Standard Randomised Controlled Trials number 47718479), with a mean planning target volume (PTV) of 327 cm{sup 3}. A boost volume, PTV2 (GTV + 0.5 cm margin), was created. Radiobiological modeling of tumor control probability (TCP) estimated the dose required for a clinically significant (+20%) increase in local control as 62.5more » Gy/25 fractions. A RapidArc (RA) plan with a simultaneously integrated boost (SIB) to PTV2 (RA{sub 62.5}) was compared to a standard dose plan of 50 Gy/25 fractions (RA{sub 50}). Dose-volume metrics and estimates of normal tissue complication probability (NTCP) for heart and lungs were compared. Results: Clinically acceptable dose escalation was feasible for 16 of 21 patients, with significant gains (>18%) in tumor control from 38.2% (RA{sub 50}) to 56.3% (RA{sub 62.5}), and only a small increase in predicted toxicity: median heart NTCP 4.4% (RA{sub 50}) versus 5.6% (RA{sub 62.5}) P<.001 and median lung NTCP 6.5% (RA{sub 50}) versus 7.5% (RA{sub 62.5}) P<.001. Conclusions: Dose escalation to the GTV to improve local control is possible when overlap between PTV and organ-at-risk (<8% heart volume and <2.5% lung volume overlap for this study) generates only negligible increase in lung or heart toxicity. These predictions from radiobiological modeling should be tested in future clinical trials.« less

  16. TH-A-BRD-01: Radiation Biology for Radiation Therapy Physicists

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Orton, C; Borras, C; Carlson, D

    Mechanisms by which radiation kills cells and ways cell damage can be repaired will be reviewed. The radiobiological parameters of dose, fractionation, delivery time, dose rate, and LET will be discussed. The linear-quadratic model for cell survival for high and low dose rate treatments and the effect of repopulation will be presented and discussed. The rationale for various radiotherapy techniques such as conventional fractionation, hyperfractionation, hypofractionation, and low and high dose rate brachytherapy, including permanent implants, will be presented. The radiobiological principles underlying radiation protection guidelines and the different radiation dosimetry terms used in radiation biology and in radiation protectionmore » will be reviewed. Human data on radiation induced cancer, including increases in the risk of second cancers following radiation therapy, as well as data on radiation induced tissue reactions, such as cardiovascular effects, for follow up times up to 20–40 years, published by ICRP, NCRP and BEIR Committees, will be examined. The latest risk estimates per unit dose will be presented. Their adoption in recent radiation protection standards and guidelines and their impact on patient and workers safety in radiotherapy will be discussed. Biologically-guided radiotherapy (BGRT) provides a systematic method to derive prescription doses that integrate patient-specific information about tumor and normal tissue biology. Treatment individualization based on patient-specific biology requires the identification of biological objective functions to facilitate the design and comparison of competing treatment modalities. Biological objectives provide a more direct approach to plan optimization instead of relying solely on dose-based surrogates and can incorporate factors that alter radiation response, such as DNA repair, tumor hypoxia, and relative biological effectiveness. We review concepts motivating biological objectives and provide examples of how they might be used to address clinically relevant problems. Underlying assumptions and limitations of existing models and their proper application will be discussed. This multidisciplinary educational session combines the fundamentals of radiobiology for radiation therapy and radiation protection with the practical application of biophysical models for treatment planning and evaluation. Learning Objectives: To understand fractionation in teletherapy and dose rate techniques in brachytherapy. To understand how the linear-quadratic models the effect of radiobiological parameters for radiotherapy. To understand the radiobiological basis of radiation protection standards applied to radiotherapy. To distinguish between stochastic effects and tissue reactions. To learn how to apply concepts of biological effective dose and RBE-weighted dose and to incorporate biological factors that alter radiation response. To discuss clinical strategies to increase therapeutic ratio, i.e., maximize local control while minimizing the risk of acute and late normal tissue effects.« less

  17. Trends of CT utilisation in an emergency department in Taiwan: a 5-year retrospective study

    PubMed Central

    Hu, Sung-Yuan; Hsieh, Ming-Shun; Lin, Meng-Yu; Hsu, Chiann-Yi; Lin, Tzu-Chieh; How, Chorng-Kuang; Wang, Chen-Yu; Tsai, Jeffrey Che-Hung; Wu, Yu-Hui; Chang, Yan-Zin

    2016-01-01

    Objectives To investigate the association between the trends of CT utilisation in an emergency department (ED) and changes in clinical imaging practice and patients' disposition. Setting A hospital-based retrospective observational study of a public 1520-bed referral medical centre in Taiwan. Participants Adult ED visits (aged ≥18 years) during 2009–2013, with or without receiving CT, were enrolled as the study participants. Main outcome measures For all enrolled ED visits, we retrospectively analysed: (1) demographic characteristics, (2) triage categories, (3) whether CT was performed and the type of CT scan, (4) further ED disposition, (5) ED cost and (6) ED length of stay. Results In all, 269 239 adult ED visits (148 613 male patients and 120 626 female patients) were collected during the 5-year study period, comprising 38 609 CT scans. CT utilisation increased from 11.10% in 2009 to 17.70% in 2013 (trend test, p<0.001). Four in 5 types of CT scan (head, chest, abdomen and miscellaneous) were increasingly utilised during the study period. Also, CT was increasingly ordered annually in all age groups. Although ED CT utilisation rates increased markedly, the annual ED visits did not actually increase. Moreover, the subsequent admission rate, after receiving ED CT, declined (59.9% in 2009 to 48.2% in 2013). Conclusions ED CT utilisation rates increased significantly during 2009–2013. Emergency physicians may be using CT for non-emergent studies in the ED. Further investigation is needed to determine whether increasing CT utilisation is efficient and cost-effective. PMID:27279477

  18. The development and characterization of a first generation carbon nanotube x-ray based microbeam radiation therapy system

    NASA Astrophysics Data System (ADS)

    Hadsell, Michael John, Jr.

    Microbeam radiation therapy (MRT) is a new type of cancer treatment currently being studied at scattered synchrotron sites throughout the world. It has been shown to be capable of ablating aggressive brain tumors in rats while almost completely sparing the surrounding normal tissue. This promising technique has yet to find its way to the clinic, however, because the radiobiological mechanisms behind its efficacy are still largely unknown. This is partly due to the lack of a compact device that could facilitate more large scale research. The challenges inherent to creating a compact device lie within the structure of MRT, which uses parallel arrays of ultra high-dose, orthovoltage, microplanar beams on the order of 100mum thick and separated by four to ten times their width. Because of focal spot limitations, current commercial orthovoltage devices are simply not capable of creating such arrays at dose rates high enough for effective treatment while maintaining the microbeam pattern necessary to retain the high therapeutic ratio of the technique. Therefore, the development of a compact MRT device using carbon nanotube (CNT) cathode based X-ray technology is presented here. CNT cathodes have been shown to be capable of creating novel focal spot arrays on a single anode while being robust enough for long-term use in X-ray tubes. Using these cathodes, an X-ray tube with a single focal line has been created for the delivery of MRT dose distributions in radiobiological studies on small animals. In this work, the development process and final design of this specialized device will be detailed, along with the optimization and stabilization of its use for small animal studies. In addition, a detailed characterization of its final capabilities will be given; including a comprehensive measurement of its X-ray focal line dimensions, a description and evaluation of its collimator alignment and microbeam dimensions, and a full-scale phantom-based quantification of its dosimetric output. Finally, future project directions will be described briefly along with plans for a second generation device. Based on the results of this work, it is the author's belief that compact CNT MRT devices have definite commercialization potential for radiobiological research.

  19. Measures of upper limb function for people with neck pain: a systematic review of measurement and practical properties (protocol).

    PubMed

    Alreni, Ahmad Salah Eldin; Harrop, Deborah; Gumber, Anil; McLean, Sionnadh

    2015-04-07

    Upper limb disability is a common musculoskeletal condition frequently associated with neck pain. Recent literature has reported the need to utilise validated upper limb outcome measures in the assessment and management of patients with neck pain. However, there is a lack of clear guidance about the suitability of available measures, which may impede utilisation. This review will identify all available measures of upper limb function developed for use in neck pain patients and evaluate their measurement and practical properties in order to identify those measures that are most appropriate for use in clinical practice and research. This review will be performed in two phases. Phase one will identify all measures used to assess upper limb function for patients with neck pain. Phase two will identify all available studies of the measurement and practical properties of identified instrument. The COnsensus-based Standards for selection of health Measurement INstrument (COSMIN) will be used to evaluate the methodological quality of the included studies. To ensure methodological rigour, the findings of this review will be reported in accordance with the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) guideline. Optimal management of patients with neck pain should incorporate upper limb rehabilitation. The findings of this study will assist clinicians who seek to utilise suitable and accurate measures to assess upper limb function for a patient with neck pain. In addition, the findings of this study may suggest new research directions to support the development of upper limb outcome measures for patients with neck pain. PROSPERO CRD42015016624.

  20. Overview of the NASA space radiation laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    La Tessa, Chiara; Sivertz, Michael; Chiang, I-Hung

    The NASA Space Radiation Laboratory (NSRL) is a multidisciplinary center for space radiation research funded by NASA and located at the Brookhaven National Laboratory (BNL), Upton NY. Operational since 2003, the scope of NSRL is to provide ion beams in support of the NASA Humans in Space program in radiobiology, physics and engineering to measure the risk and ameliorate the effect of radiation in space. Recently, it has also been recognized as the only facility in the U.S. currently capable of contributing to heavy ion radiotherapy research. Finally, this work contains a general overview of NSRL structure, capabilities and operation.

  1. Overview of the NASA space radiation laboratory

    DOE PAGES

    La Tessa, Chiara; Sivertz, Michael; Chiang, I-Hung; ...

    2016-11-11

    The NASA Space Radiation Laboratory (NSRL) is a multidisciplinary center for space radiation research funded by NASA and located at the Brookhaven National Laboratory (BNL), Upton NY. Operational since 2003, the scope of NSRL is to provide ion beams in support of the NASA Humans in Space program in radiobiology, physics and engineering to measure the risk and ameliorate the effect of radiation in space. Recently, it has also been recognized as the only facility in the U.S. currently capable of contributing to heavy ion radiotherapy research. Finally, this work contains a general overview of NSRL structure, capabilities and operation.

  2. Operationalisation of the construct of access to dental care: a position paper and proposed conceptual definitions.

    PubMed

    Harris, R V

    2013-06-01

    'Access' is a term readily used in a political and policy context, but one which has not leant itself to measurement of progress towards policy goals or comparisons between health systems. Like 'quality', 'access' is a multi-dimensional construct, but currently often remains a vague and abstract concept which is difficult to translate into something specific, concrete and therefore measureable. The paper describes previous work and identifies a need for a greater consensus and conceptual clarity in the selection of metrics for dental access. The construct of dental access is described as involving the concepts of 1: opportunity for access; 2, realised access (utilisation); 3, equity and 4, outcomes. Proposed conceptual definitions are given and a case made for measuring 'initial utilisation' separately from 'continued utilisation', reflecting modern approaches which distinguish 'entry access' (gaining entry to the dental care system), from the process of gaining access to higher levels of care. Using a distinction between 'entry access' and 'effective access' allows a choice of whether to restrict measurement to mainly supply side considerations, or alternatively to extend the measurement to include whether there is equity in the proportion of patients who are able obtain effective needed interventions. A development of conceptual definitions of dental access could facilitate measurement of progress towards policy goals and operationalisation of the construct.

  3. Osteopontin and splice variant expression level in human malignant glioma: radiobiologic effects and prognosis after radiotherapy.

    PubMed

    Güttler, Antje; Giebler, Maria; Cuno, Peter; Wichmann, Henri; Keßler, Jacqueline; Ostheimer, Christian; Söling, Ariane; Strauss, Christian; Illert, Jörg; Kappler, Matthias; Vordermark, Dirk; Bache, Matthias

    2013-09-01

    We investigated the role of the hypoxia-associated secreted glycoprotein osteopontin (OPN) in the response of malignant glioma to radiotherapy by characterizing OPN and its splice variants in vitro and in patient material. The effect of siRNA knockdown of OPN splice variants on cellular and radiobiologic behavior was analyzed in U251MG cells using OpnS siRNA (inhibition of all OPN splice variants) and OpnAC siRNA (knockdown only of OPNa and OPNc). OPN and splice variant mRNA levels were quantified in archival material of 41 glioblastoma tumor samples. Plasma OPN was prospectively measured in 33 malignant glioma patients. Inhibition of OPNa and OPNc (OpnAC) reduced clonogenic survival in U251MG cells but did not affect proliferation, migration or apoptosis. Knockdown of all OPN splice variants (OpnS) resulted in an even stronger inhibition of clonogenic survival, while cell proliferation and migration were reduced and rate of apoptosis was increased. Additional irradiation had additive effects with both siRNAs. Plasma OPN increased continuously in malignant glioma patients and was associated with poor survival. OPNb is partially able to compensate the effects of OPNa and OPNc knockdown in U251MG cells. High OPN plasma levels at the end of radiotherapy are associated with poor survival. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  4. A novel phantom model for mouse tumor dose assessment under MV beams

    PubMed Central

    Gossman, Michael S.; Das, Indra J.; Sharma, Subhash C.; Lopez, Jeffrey P.; Howard, Candace M.; Claudio, Pier P.

    2011-01-01

    Purpose In order to determine a mouse’s dose accurately and prior to engaging in live mouse radiobiological research, a tissue-equivalent tumor-bearing phantom mouse was constructed and bored to accommodate detectors. Methods and Materials Comparisons were made between four different types of radiation detectors, each inserted into the phantom mouse for radiation measurement under a 6 MV linear accelerator beam. Dose detection response from a diode, thermoluminescent dosimeters, metal-oxide semiconductor field-effect transistors were used and compared to that of a reference pin-point ionization chamber. Likewise, a computerized treatment planning system was also directly compared. Results Each detector system demonstrated results similar to the dose computed by the therapeutic treatment planning system, although some differences were noted. The average disagreement from a accelerator calibrated output dose prescription in the range of 200–400 cGy were −0.4% ± 0.5σ for the diode, −2.4% ± 2.6σ for the TLD, −2.9% ± 5.0σ for the MOSFET and +1.3% ± 1.4σ for the treatment planning system. Conclusions This phantom mouse design is unique, simple, reproducible and therefore recommended as a standard approach to dosimetry for radiobiological mouse studies by means of any of the detectors used in this study. We fully advocate for treatment planning modeling when possible prior to linac-based dose delivery. PMID:22048493

  5. Antenatal Care Utilisation and Content between Low-Risk and High-Risk Pregnant Women

    PubMed Central

    Yeoh, Ping Ling; Hornetz, Klaus; Dahlui, Maznah

    2016-01-01

    Background The purpose of antenatal care is to monitor and improve the wellbeing of the mother and foetus. The World Health Organization recommends risk-oriented strategy that includes: (i) routine care to all women, (ii) additional care for women with moderately severe diseases and complications, (iii) specialised obstetrical and neonatal care for women with severe diseases and complications. Antenatal care is concerned with adequate care in order to be effective. Measurement for adequacy of antenatal care often applies indexes that assess initiation of care and number of visits. In addition, adequacy of care content should also be assessed. Results of studies in developed settings demonstrate that women without risk factors use antenatal services more frequently than recommended. Such over-utilisation is problematic for low-resourced settings. Moreover, studies show that a substantial proportion of high-risk women had utilisation or content of care below the recommended standard. Yet studies in developing countries have seldom included a comparison between low-risk and high-risk women. The purpose of the study was therefore to assess adequacy of care and pregnancy outcomes for the different risk groups. Methods A retrospective study using a multistage sampling technique, at public-funded primary health care clinics was conducted. Antenatal utilisation level was assessed using a modified Adequacy of Prenatal Care Utilisation index that measures the timing for initiation of care and observed-to-expected visits ratio. Adequacy of antenatal care content assessed compliance to routine care based on the local guidelines. Results Intensive or “adequate-plus” antenatal care utilisation as defined by the modified index was noted in over half of the low-risk women. On the other hand, there were 26% of the high-risk women without the expected intensive utilisation. Primary- or non-educated high-risk women were less likely to have a higher antenatal care utilisation level compared with tertiary educated ones (OR = 0.20, P = 0.003). Half of all women had <80% of the recommended antenatal care content. A higher proportion of high-risk than low-risk women scored <80% of the routine care content (p<0.015). The majority of the additional laboratory tests were performed on high-risk women. Provision of antenatal education showed comparatively poor compliance to guidelines, more than half of the antenatal advice topics assessed were rarely provided to the women. High-risk women were associated with a higher prevalence of adverse pregnancy outcome. Conclusions Disproportionate utilisation of antenatal care according to risk level of pregnancy indicates the need for better scheduling of care. The risk-oriented approach often results in a tendency to focus on the risk conditions of the women. Training interventions are recommended to improve communication and to help healthcare professionals understand the priorities of the women. Further studies are required to assess the reason for disproportionate utilisation of antenatal care according to risk level and how delivery of antenatal advice can be improved, reviewing both user and provider perspectives. PMID:27010482

  6. The role of non-need factors in individual GP utilisation analysis and their implications for the pursuance of equity: a cross-country comparison.

    PubMed

    McGregor, P; McKee, P; O'Neill, C

    2008-05-01

    A substantial amount of health care resources is allocated within the UK using formulae that relate funding to measures of population need. The aim of this paper is to demonstrate the importance of non-need factors in determining utilisation of services at an individual level and explore the implications inclusion of such factors has in the consideration of equity. In the paper we develop a utility model that accords a role to non-health factors in the determination of service use. A series of functions incorporating non-health factors as explanatory variables in GP utilisation functions are estimated using data from the British Household Panel Survey. The functions are decomposed to ascertain the role of service structure and examine the role of income across the four countries of the UK in explaining utilisation. The implications of our findings for the pursuance of equity in the NHS when individual choice has an explicit role are discussed.

  7. Utilisation of the Magnetic Sensor in a Smartphone for Facile Magnetostatics Experiment: Magnetic Field Due to Electrical Current in Straight and Loop Wires

    ERIC Educational Resources Information Center

    Septianto, R. D.; Suhendra, D.; Iskandar, F.

    2017-01-01

    This paper reports on the result of a research into the utilisation of a smartphone for the study of magnetostatics on the basis of experiments. The use of such a device gives great measurement result and thus it can replace magnetic sensor tools that are relatively expensive. For the best experimental result, firstly the position of the magnetic…

  8. Estimation of an optimal chemotherapy utilisation rate for cancer: setting an evidence-based benchmark for quality cancer care.

    PubMed

    Jacob, S A; Ng, W L; Do, V

    2015-02-01

    There is wide variation in the proportion of newly diagnosed cancer patients who receive chemotherapy, indicating the need for a benchmark rate of chemotherapy utilisation. This study describes an evidence-based model that estimates the proportion of new cancer patients in whom chemotherapy is indicated at least once (defined as the optimal chemotherapy utilisation rate). The optimal chemotherapy utilisation rate can act as a benchmark for measuring and improving the quality of care. Models of optimal chemotherapy utilisation were constructed for each cancer site based on indications for chemotherapy identified from evidence-based treatment guidelines. Data on the proportion of patient- and tumour-related attributes for which chemotherapy was indicated were obtained, using population-based data where possible. Treatment indications and epidemiological data were merged to calculate the optimal chemotherapy utilisation rate. Monte Carlo simulations and sensitivity analyses were used to assess the effect of controversial chemotherapy indications and variations in epidemiological data on our model. Chemotherapy is indicated at least once in 49.1% (95% confidence interval 48.8-49.6%) of all new cancer patients in Australia. The optimal chemotherapy utilisation rates for individual tumour sites ranged from a low of 13% in thyroid cancers to a high of 94% in myeloma. The optimal chemotherapy utilisation rate can serve as a benchmark for planning chemotherapy services on a population basis. The model can be used to evaluate service delivery by comparing the benchmark rate with patterns of care data. The overall estimate for other countries can be obtained by substituting the relevant distribution of cancer types. It can also be used to predict future chemotherapy workload and can be easily modified to take into account future changes in cancer incidence, presentation stage or chemotherapy indications. Copyright © 2014 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  9. Impact of hypoxia and the metabolic microenvironment on radiotherapy of solid tumors. Introduction of a multi-institutional research project.

    PubMed

    Zips, Daniel; Adam, Markus; Flentje, Michael; Haase, Axel; Molls, Michael; Mueller-Klieser, Wolfgang; Petersen, Cordula; Philbrook, Christine; Schmitt, Peter; Thews, Oliver; Walenta, Stefan; Baumann, Michael

    2004-10-01

    Recent developments in imaging technology and tumor biology have led to new techniques to detect hypoxia and related alterations of the metabolic microenvironment in tumors. However, whether these new methods can predict radiobiological hypoxia and outcome after fractionated radiotherapy still awaits experimental evaluation. The present article will introduce a multi-institutional research project addressing the impact of hypoxia and the metabolic microenvironment on radiotherapy of solid tumors. The four laboratories involved are situated at the universities of Dresden, Mainz, Munich and Würzburg, Germany. The joint scientific project started to collect data obtained on a set of ten different human tumor xenografts growing in nude mice by applying various imaging techniques to detect tumor hypoxia and related parameters of the metabolic microenvironment. These techniques include magnetic resonance imaging and spectroscopy, metabolic mapping with quantitative bioluminescence and single-photon imaging, histological multiparameter analysis of biochemical hypoxia, perfusion and vasculature, and immunohistochemistry of factors related to angiogenesis, invasion and metastasis. To evaluate the different methods, baseline functional radiobiological data including radiobiological hypoxic fraction and outcome after fractionated irradiation will be determined. Besides increasing our understanding of tumor biology, the project will focus on new, clinically applicable strategies for microenvironment profiling and will help to identify those patients that might benefit from targeted interventions to improve tumor oxygenation.

  10. Consequences of anorectal cancer atlas implementation in the cooperative group setting: radiobiologic analysis of a prospective randomized in silico target delineation study.

    PubMed

    Mavroidis, Panayiotis; Giantsoudis, Drosoula; Awan, Musaddiq J; Nijkamp, Jasper; Rasch, Coen R N; Duppen, Joop C; Thomas, Charles R; Okunieff, Paul; Jones, William E; Kachnic, Lisa A; Papanikolaou, Niko; Fuller, Clifton D

    2014-09-01

    The aim of this study is to ascertain the subsequent radiobiological impact of using a consensus guideline target volume delineation atlas. Using a representative case and target volume delineation instructions derived from a proposed IMRT rectal cancer clinical trial, gross tumor volume (GTV) and clinical/planning target volumes (CTV/PTV) were contoured by 13 physician observers (Phase 1). The observers were then randomly assigned to follow (atlas) or not-follow (control) a consensus guideline/atlas for anorectal cancers, and instructed to re-contour the same case (Phase 2). The atlas group was found to have increased tumor control probability (TCP) after the atlas intervention for both the CTV (p<0.0001) and PTV1 (p=0.0011) with decreasing normal tissue complication probability (NTCP) for small intestine, while the control group did not. Additionally, the atlas group had reduced variance in TCP for all target volumes and reduced variance in NTCP for the bowel. In Phase 2, the atlas group had increased TCP relative to the control for CTV (p=0.03). Visual atlas and consensus treatment guideline usage in the development of rectal cancer IMRT treatment plans reduced the inter-observer radiobiological variation, with clinically relevant TCP alteration for CTV and PTV volumes. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  11. Operation CASTLE. Operation Plan Number 3-53. March - May 1954,

    DTIC Science & Technology

    Nuclear radiation, *Nuclear explosions, *Radiation dosage, *Test methods, *Military operations, *Military planning, Radiobiology, Missions, Marshall Islands , Eniwetok Atoll, Bikini Atoll, Atmospheric physics, Low level, Radiation

  12. [Combined internal-external radiotherapy (CIERT) in a cell model].

    PubMed

    Oehme, Liane; Bartzsch, Thomas; Maucksch, Ute; Freudenberg, Robert; Wunderlich, Gerd; Kotzerke, Jörg

    2018-06-01

    Combined internal-external radiotherapy (CIERT) requires a unified assessment of biologic radiation effects in addition to the total dose. The concept of biological effective dose (BED) was evaluated in a cell model. The thyroid NIS-positive cell line FRTL-5 was irradiated with X-ray and the radiotracer Tc-99m pertechnetate either alone or in combination. The cellular uptake of the radionuclide during the incubation time of 24 h was controlled by the presence or absence of perchlorate. Dose calculation was performed based on measured uptake values. Cell specific radiobiologic parameters were derived from dose effect curves using the colony forming assay as biological endpoint. For the combination of the radiation qualities the sequence and time difference were varied. Cell survival was compared with the prediction of the BED model. The radiobiologic parameters from X-ray dose response were α = (0.22 ± 0.02) Gy -1 and β = (0.021 ± 0.001) Gy -2 . The half life for repair was (1.51 ± 0.21) h. These values could also explain the dose response curves for Tc-99m-irradiation with exponential decreasing dose rate. CIERT experiments showed no significant differences in cell survival regarding sequence and irradiation break. When the radionuclide uptake was not prevented the cell survival for the combination of X-ray and Tc-99m was lower than the prediction by BED calculations. The validity of the BED formalism for different dose rates and radiation qualities was verified. Supraaddive effects measured in the combination of X-ray and intracellular Tc-99m might be caused by Auger and conversion electrons, however further experiments are necessary. Schattauer GmbH.

  13. Monte Carlo simulations of a low energy proton beamline for radiobiological experiments.

    PubMed

    Dahle, Tordis J; Rykkelid, Anne Marit; Stokkevåg, Camilla H; Mairani, Andrea; Görgen, Andreas; Edin, Nina J; Rørvik, Eivind; Fjæra, Lars Fredrik; Malinen, Eirik; Ytre-Hauge, Kristian S

    2017-06-01

    In order to determine the relative biological effectiveness (RBE) of protons with high accuracy, radiobiological experiments with detailed knowledge of the linear energy transfer (LET) are needed. Cell survival data from high LET protons are sparse and experiments with low energy protons to achieve high LET values are therefore required. The aim of this study was to quantify LET distributions from a low energy proton beam by using Monte Carlo (MC) simulations, and to further compare to a proton beam representing a typical minimum energy available at clinical facilities. A Markus ionization chamber and Gafchromic films were employed in dose measurements in the proton beam at Oslo Cyclotron Laboratory. Dose profiles were also calculated using the FLUKA MC code, with the MC beam parameters optimized based on comparisons with the measurements. LET spectra and dose-averaged LET (LET d ) were then estimated in FLUKA, and compared with LET calculated from an 80 MeV proton beam. The initial proton energy was determined to be 15.5 MeV, with a Gaussian energy distribution of 0.2% full width at half maximum (FWHM) and a Gaussian lateral spread of 2 mm FWHM. The LET d increased with depth, from approximately 5 keV/μm in the entrance to approximately 40 keV/μm in the distal dose fall-off. The LET d values were considerably higher and the LET spectra were much narrower than the corresponding spectra from the 80 MeV beam. MC simulations accurately modeled the dose distribution from the proton beam and could be used to estimate the LET at any position in the setup. The setup can be used to study the RBE for protons at high LET d , which is not achievable in clinical proton therapy facilities.

  14. Heavy Charged Particle Radiobiology: Using Enhanced Biological Effectiveness and Improved Beam Focusing to Advance Cancer Therapy

    PubMed Central

    Allen, Christopher; Borak, Thomas B.; Tsujii, Hirohiko; Nickoloff, Jac A.

    2011-01-01

    Ionizing radiation causes many types of DNA damage, including base damage and single- and double-strand breaks. Photons, including X-rays and γ-rays, are the most widely used type of ionizing radiation in radiobiology experiments, and in radiation cancer therapy. Charged particles, including protons and carbon ions, are seeing increased use as an alternative therapeutic modality. Although the facilities needed to produce high energy charged particle beams are more costly than photon facilities, particle therapy has shown improved cancer survival rates, reflecting more highly focused dose distributions and more severe DNA damage to tumor cells. Despite early successes of charged particle radiotherapy, there is room for further improvement, and much remains to be learned about normal and cancer cell responses to charged particle radiation. PMID:21376738

  15. Small-scale laser based electron accelerators for biology and medicine: a comparative study of the biological effectiveness

    NASA Astrophysics Data System (ADS)

    Labate, Luca; Andreassi, Maria Grazia; Baffigi, Federica; Basta, Giuseppina; Bizzarri, Ranieri; Borghini, Andrea; Candiano, Giuliana C.; Casarino, Carlo; Cresci, Monica; Di Martino, Fabio; Fulgentini, Lorenzo; Ghetti, Francesco; Gilardi, Maria Carla; Giulietti, Antonio; Köster, Petra; Lenci, Francesco; Levato, Tadzio; Oishi, Yuji; Russo, Giorgio; Sgarbossa, Antonella; Traino, Claudio; Gizzi, Leonida A.

    2013-05-01

    Laser-driven electron accelerators based on the Laser Wakefield Acceleration process has entered a mature phase to be considered as alternative devices to conventional radiofrequency linear accelerators used in medical applications. Before entering the medical practice, however, deep studies of the radiobiological effects of such short bunches as the ones produced by laser-driven accelerators have to be performed. Here we report on the setup, characterization and first test of a small-scale laser accelerator for radiobiology experiments. A brief description of the experimental setup will be given at first, followed by an overview of the electron bunch characterization, in particular in terms of dose delivered to the samples. Finally, the first results from the irradiation of biological samples will be briefly discussed.

  16. [Cytogenetic effects in experimental exposure to the heavy charged particles of galactic cosmic radiation on the Kosmos-1129 biosatellite].

    PubMed

    Nevzgodina, L V; Maksimova, E N

    1982-01-01

    The experiment was carried out on lattice (Lactuca sativa) seeds flown in a biocontainer equipped with plastic detectors to record heavy charged particles (HCP). The purpose of the experiment was to determine the yield of aberrant cells as a result of irradiation, and to identify this effect as a function of HCP topography in the seed. The cytogenetic examination of flight seedlings revealed a significant difference between the seeds which were hit with HCP and those that remained intact. This indicates a significant contribution of the heavy component of galactic cosmic rediation into the radiobiological effect. The relationship between the radiobiological effect and the HCP topography in the seed was established: zones of the root and stem meristema proved to be most sensitive targets.

  17. A study of the radiobiological modeling of the conformal radiation therapy in cancer treatment

    NASA Astrophysics Data System (ADS)

    Pyakuryal, Anil Prasad

    Cancer is one of the leading causes of mortalities in the world. The precise diagnosis of the disease helps the patients to select the appropriate modality of the treatments such as surgery, chemotherapy and radiation therapy. The physics of X-radiation and the advanced imaging technologies such as positron emission tomography (PET) and computed tomography (CT) plays an important role in the efficient diagnosis and therapeutic treatments in cancer. However, the accuracy of the measurements of the metabolic target volumes (MTVs) in the PET/CT dual-imaging modality is always limited. Similarly the external beam radiation therapy (XRT) such as 3D conformal radiotherapy (3DCRT) and intensity modulated radiation therapy (IMRT) is the most common modality in the radiotherapy treatment. These treatments are simulated and evaluated using the XRT plans and the standard methodologies in the commercial planning system. However, the normal organs are always susceptible to the radiation toxicity in these treatments due to lack of knowledge of the appropriate radiobiological models to estimate the clinical outcomes. We explored several methodologies to estimate MTVs by reviewing various techniques of the target volume delineation using the static phantoms in the PET scans. The review suggests that the more precise and practical method of delineating PET MTV should be an intermediate volume between the volume coverage for the standardized uptake value (SUV; 2.5) of glucose and the 50% (40%) threshold of the maximum SUV for the smaller (larger) volume delineations in the radiotherapy applications. Similarly various types of optimal XRT plans were designed using the CT and PET/CT scans for the treatment of various types of cancer patients. The qualities of these plans were assessed using the universal plan-indices. The dose-volume criteria were also examined in the targets and organs by analyzing the conventional dose-volume histograms (DVHs). The biological models such as tumor control probability based on Poisson statistics model, and normal tissue complication probabilities based on Lyman-Kutcher-Burman model, were efficient to estimate the radiobiological outcomes of the treatments by taking into account of the dose-volume effects in the organs. Furthermore, a novel technique of spatial DVH analysis was also found to be useful to determine the primary cause of the complications in the critical organs in the treatments. The study also showed that the 3DCRT and IMRT techniques offer the promising results in the XRT treatment of the left-breast and the prostate cancer patients respectively. Unfortunately, several organs such as salivary glands and larynx, and esophagus, were found to be significantly vulnerable to the radiation toxicity in the treatment of the head and neck (HN), and left-lung cancer patients respectively. The radiobiological outcomes were also found to be consistent with the clinical results of the IMRT based treatments of a significant number of the HN cancer patients.

  18. Monte Carlo studies on photon interactions in radiobiological experiments

    PubMed Central

    Shahmohammadi Beni, Mehrdad; Krstic, D.; Nikezic, D.

    2018-01-01

    X-ray and γ-ray photons have been widely used for studying radiobiological effects of ionizing radiations. Photons are indirectly ionizing radiations so they need to set in motion electrons (which are a directly ionizing radiation) to perform the ionizations. When the photon dose decreases to below a certain limit, the number of electrons set in motion will become so small that not all cells in an “exposed” cell population can get at least one electron hit. When some cells in a cell population are not hit by a directly ionizing radiation (in other words not irradiated), there will be rescue effect between the irradiated cells and non-irradiated cells, and the resultant radiobiological effect observed for the “exposed” cell population will be different. In the present paper, the mechanisms underlying photon interactions in radiobiological experiments were studied using our developed NRUphoton computer code, which was benchmarked against the MCNP5 code by comparing the photon dose delivered to the cell layer underneath the water medium. The following conclusions were reached: (1) The interaction fractions decreased in the following order: 16O > 12C > 14N > 1H. Bulges in the interaction fractions (versus water medium thickness) were observed, which reflected changes in the energies of the propagating photons due to traversals of different amount of water medium as well as changes in the energy-dependent photon interaction cross-sections. (2) Photoelectric interaction and incoherent scattering dominated for lower-energy (10 keV) and high-energy (100 keV and 1 MeV) incident photons. (3) The fractions of electron ejection from different nuclei were mainly governed by the photoelectric effect cross-sections, and the fractions from the 1s subshell were the largest. (4) The penetration fractions in general decreased with increasing medium thickness, and increased with increasing incident photon energy, the latter being explained by the corresponding reduction in interaction cross-sections. (5) The areas under the angular distribution curves of photons exiting the medium layer and subsequently undergoing interactions within the cell layer became smaller for larger incident photon energies. (6) The number of cells suffering at least one electron hit increased with the administered dose. For larger incident photon energies, the numbers of cells suffering at least one electron hit became smaller, which was attributed to the reduction in the photon interaction cross-section. These results highlighted the importance of the administered dose in radiobiological experiments. In particular, the threshold administered doses at which all cells in the exposed cell array suffered at least one electron hit might provide hints on explaining the intriguing observation that radiation-induced cancers can be statistically detected only above the threshold value of ~100 mSv, and thus on reconciling controversies over the linear no-threshold model. PMID:29561871

  19. Proceedings of the First International Symposium on the Biological Interpretation of Dose from Accelerator-Produced Radiation, Held at the Lawrence Radiation Laboratory, Berkeley, California, March 13--16, 1967

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wallace, R.

    1967-03-13

    The objective of the meeting was to provide a companion meeting to the ''First Symposium on Accelerator Radiation Dosimetry and Experience'' which was held November 3-5, 1965, at the Brookhaven National Laboratory. This first symposium was limited in scope to an intensified discussion of dosimetry techniques. The biology which is associated with high energy radiation was specifically excluded, since it was the original plan to hold a second symposium devoted entirely to biology. Thus the present Symposium was a sequel to the first and they were inseparable in their objectives. Since those attending the BNL Symposium were almost entirely healthmore » physicists with a background in physical science and actively engaged in the solution of radiation protection problems at high energy accelerators, it was felt that it would be necessary to begin the BID Symposium with a general review session on radiation biology, in order to provide a biological background for the proper understanding of the later sessions. This first session was arranged to give the health physicist a meaningful transition from fundamental radiobiological considerations to current new research activities in high energy biology. In our opinion, and also based on the comments of several of those attending these objectives were quite well attained. The talks by Bond, Robertson, Brustad, Wolff, and Patt were quite exhaustive as an introduction to the several areas of specialization in radiobiology. The overall purpose of the meeting was of course to inform the health physicists about the state of knowledge in advanced biological research as it might apply to their problems. It has often been said that it takes a long time for laboratory findings to be applied in practical situations, but this is certainly not true in radiobiology. Through this conference and others like it, the most recent understanding of high energy radiobiology is available to the practicing health physicist and is probably used fairly effectively. In addition, much of this material applies equally well to reactor and space radiation problems, and some of the participants were from these areas as well.« less

  20. Antiproton radiotherapy.

    PubMed

    Bassler, Niels; Alsner, Jan; Beyer, Gerd; DeMarco, John J; Doser, Michael; Hajdukovic, Dragan; Hartley, Oliver; Iwamoto, Keisuke S; Jäkel, Oliver; Knudsen, Helge V; Kovacevic, Sandra; Møller, Søren Pape; Overgaard, Jens; Petersen, Jørgen B; Solberg, Timothy D; Sørensen, Brita S; Vranjes, Sanja; Wouters, Bradly G; Holzscheiter, Michael H

    2008-01-01

    Antiprotons are interesting as a possible future modality in radiation therapy for the following reasons: When fast antiprotons penetrate matter, protons and antiprotons have near identical stopping powers and exhibit equal radiobiology well before the Bragg-peak. But when the antiprotons come to rest at the Bragg-peak, they annihilate, releasing almost 2 GeV per antiproton-proton annihilation. Most of this energy is carried away by energetic pions, but the Bragg-peak of the antiprotons is still locally augmented with approximately 20-30 MeV per antiproton. Apart from the gain in physical dose, an increased relative biological effect also has been observed, which can be explained by the fact that some of the secondary particles from the antiproton annihilation exhibit high-LET properties. Finally, the weakly interacting energetic pions, which are leaving the target volume, may provide a real time feedback on the exact location of the annihilation peak. We have performed dosimetry experiments and investigated the radiobiological properties using the antiproton beam available at CERN, Geneva. Dosimetry experiments were carried out with ionization chambers, alanine pellets and radiochromic film. Radiobiological experiments were done with V79 WNRE Chinese hamster cells. The radiobiological experiments were repeated with protons and carbon ions at TRIUMF and GSI, respectively, for comparison. Several Monte Carlo particle transport codes were investigated and compared with our experimental data obtained at CERN. The code that matched our data best was used to generate a set of depth dose data at several energies, including secondary particle-energy spectra. This can be used as base data for a treatment planning software such as TRiP. Our findings from the CERN experiments indicate that the biological effect of antiprotons in the plateau region may be reduced by a factor of 4 for the same biological target dose in a spread-out Bragg-peak, when comparing with protons. The extension of TRiP to handle antiproton beams is currently in progress. This will enable us to perform planning studies, where the potential clinical consequences can be examined, and compared to those of other beam modalities such as protons, carbon ions, or IMRT photons.

  1. The use of TCP based EUD to rank and compare lung radiotherapy plans: in-silico study to evaluate the correlation between TCP with physical quality indices.

    PubMed

    Chaikh, Abdulhamid; Balosso, Jacques

    2017-06-01

    To apply the equivalent uniform dose (EUD) radiobiological model to estimate the tumor control probability (TCP) scores for treatment plans using different radiobiological parameter settings, and to evaluate the correlation between TCP and physical quality indices of the treatment plans. Ten radiotherapy treatment plans for lung cancer were generated. The dose distributions were calculated using anisotropic analytical algorithm (AAA). Dose parameters and quality indices derived from dose volume histograms (DVH) for target volumes were evaluated. The predicted TCP was computed using EUD model with tissue-specific parameter (a=-10). The assumed radiobiological parameter setting for adjuvant therapy [tumor dose to control 50% of the tumor (TCD 50 ) =36.5 Gy and γ 50 =0.72] and curative intent (TCD 50 =51.24 Gy and γ 50 =0.83) were used. The bootstrap method was used to estimate the 95% confidence interval (95% CI). The coefficients (ρ) from Spearman's rank test were calculated to assess the correlation between quality indices with TCP. Wilcoxon paired test was used to calculate P value. The 95% CI of TCP were 70.6-81.5 and 46.6-64.7, respectively, for adjuvant radiotherapy and curative intent. The TCP outcome showed a positive and good correlation with calculated dose to 95% of the target volume (D95%) and minimum dose (Dmin). Consistently, TCP correlate negatively with heterogeneity indices. This study confirms that more relevant and robust radiobiological parameters setting should be integrated according to cancer type. The positive correlation with quality indices gives chance to improve the clinical out-come by optimizing the treatment plans to maximize the Dmin and D95%. This attempt to increase the TCP should be carried out with the respect of dose constraints for organs at risks. However, the negative correlation with heterogeneity indices shows that the optimization of beam arrangements could be also useful. Attention should be paid to obtain an appropriate optimization of initial plans, when comparing and ranking radiotherapy plans using TCP models, to avoid over or underestimated for TCP outcome.

  2. SU-E-T-248: An Extended Generalized Equivalent Uniform Dose Accounting for Dose-Range Dependency of Radio-Biological Parameters.

    PubMed

    Troeller, A; Soehn, M; Yan, D

    2012-06-01

    Introducing an extended, phenomenological, generalized equivalent uniform dose (eEUD) that incorporates multiple volume-effect parameters for different dose-ranges. The generalized EUD (gEUD) was introduced as an estimate of the EUD that incorporates a single, tissue-specific parameter - the volume-effect-parameter (VEP) 'a'. As a purely phenomenological concept, its radio-biological equivalency to a given inhomogeneous dose distribution is not a priori clear and mechanistic models based on radio-biological parameters are assumed to better resemble the underlying biology. However, for normal organs mechanistic models are hard to derive, since the structural organization of the tissue plays a significant role. Consequently, phenomenological approaches might be especially useful in order to describe dose-response for normal tissues. However, the single parameter used to estimate the gEUD may not suffice in accurately representing more complex biological effects that have been discussed in the literature. For instance, radio-biological parameters and hence the effects of fractionation are known to be dose-range dependent. Therefore, we propose an extended phenomenological eEUD formula that incorporates multiple VEPs accounting for dose-range dependency. The eEUD introduced is a piecewise polynomial expansion of the gEUD formula. In general, it allows for an arbitrary number of VEPs, each valid for a certain dose-range. We proved that the formula fulfills required mathematical and physical criteria such as invertibility of the underlying dose-effect and continuity in dose. Furthermore, it contains the gEUD as a special case, if all VEPs are equal to 'a' from the gEUD model. The eEUD is a concept that expands the gEUD such that it can theoretically represent dose-range dependent effects. Its practicality, however, remains to be shown. As a next step, this will be done by estimating the eEUD from patient data using maximum-likelihood based NTCP modelling in the same way it is commonly done for the gEUD. © 2012 American Association of Physicists in Medicine.

  3. Overview of the NASA space radiation laboratory.

    PubMed

    La Tessa, Chiara; Sivertz, Michael; Chiang, I-Hung; Lowenstein, Derek; Rusek, Adam

    2016-11-01

    The NASA Space Radiation Laboratory (NSRL) is a multidisciplinary center for space radiation research funded by NASA and located at the Brookhaven National Laboratory (BNL), Upton NY. Operational since 2003, the scope of NSRL is to provide ion beams in support of the NASA Humans in Space program in radiobiology, physics and engineering to measure the risk and ameliorate the effect of radiation in space. Recently, it has also been recognized as the only facility in the U.S. currently capable of contributing to heavy ion radiotherapy research. This work contains a general overview of NSRL structure, capabilities and operation. Copyright © 2016 The Committee on Space Research (COSPAR). All rights reserved.

  4. [Psychometric Testing of a New Scale Assessing the Reasons for Non-Utilisation of Health Care Services by People with Migration Backgrounds].

    PubMed

    Maier, I; Kriston, L; Härter, M; Hölzel, L P; Bermejo, I

    2015-10-01

    In Germany live a lot of migrants. Cultural and migration specific aspects seem to have an effect on utilisation of health care. There are no instruments that measure such factors of influence. A systematic literature research or article that identify the difficulties of the migrants in using the health care system, was made. The relevant aspects were explored during a health related opinion survey of migrants from former USSR, Turkey, Italy and Spain. The psychometric qualities of this questionnaire were investigated with factor and reliability analyses. There were 24 reasons identified for non-utilisation health care. They were combined in a questionnaire. The factor analysis showed 2-factor structure ("janguage und information related Reasons" Chronbach's α=0.928 and "experience with/attitude toward health care system", Chronbach's α=0.879). Furthermore, there was a total scale with Chronbach's α=0.945. The acceptance was between 80.0 and 96.3%. The results confirm the psychometric quality of this measuring instrument. For further generalisability more verification will be necessary. © Georg Thieme Verlag KG Stuttgart · New York.

  5. What does 'access to health care' mean?

    PubMed

    Gulliford, Martin; Figueroa-Munoz, Jose; Morgan, Myfanwy; Hughes, David; Gibson, Barry; Beech, Roger; Hudson, Meryl

    2002-07-01

    Facilitating access is concerned with helping people to command appropriate health care resources in order to preserve or improve their health. Access is a complex concept and at least four aspects require evaluation. If services are available and there is an adequate supply of services, then the opportunity to obtain health care exists, and a population may 'have access' to services. The extent to which a population 'gains access' also depends on financial, organisational and social or cultural barriers that limit the utilisation of services. Thus access measured in terms of utilisation is dependent on the affordability, physical accessibility and acceptability of services and not merely adequacy of supply. Services available must be relevant and effective if the population is to 'gain access to satisfactory health outcomes'. The availability of services, and barriers to access, have to be considered in the context of the differing perspectives, health needs and material and cultural settings of diverse groups in society. Equity of access may be measured in terms of the availability, utilisation or outcomes of services. Both horizontal and vertical dimensions of equity require consideration. Copyright The Royal Society of Medicine Press Ltd 2002.

  6. The Safe use of Radioactive Isotopes in Teaching Experiments

    ERIC Educational Resources Information Center

    Hawcroft, D. M.; Stewart, J. C.

    1974-01-01

    This article briefly discusses some of the dangers involved in the use of radioisotopes and includes a comprehensive list of precautions and laboratory rules for use during radiobiology experiments. (Author)

  7. Associations between multimorbidity and additional burden for working-age adults with specific forms of musculoskeletal conditions: a cross-sectional study.

    PubMed

    Lowe, Dianne B; Taylor, Michael J; Hill, Sophie J

    2017-04-04

    Multiple health conditions are increasingly a problem for adults with musculoskeletal conditions. However, multimorbidity research has focused primarily on the elderly and those with a limited subset of musculoskeletal disorders. We sought to determine whether associations between multimorbidity and additional burden differ with specific forms of musculoskeletal conditions among working-age adults. Data were sourced from a nationally representative Australian survey. Specific musculoskeletal conditions examined were osteoarthritis; inflammatory arthritis; other forms of arthritis or arthropathies; musculoskeletal conditions not elsewhere specified; gout; back pain; soft tissue disorders; or osteoporosis. Multimorbidity was defined as the additional presence of one or more of the Australian National Health Priority Area conditions. Burden was assessed by self-reported measures of: (i) self-rated health (ii) musculoskeletal-related healthcare and medicines utilisation and, (iii) general healthcare utilisation. Associations between multimorbidity and additional health or healthcare utilisation burden among working-age adults (aged 18 - 64 years of age) with specific musculoskeletal conditions were estimated using logistic regression, adjusting for confounders. Interaction terms were fitted to identify whether there were specific musculoskeletal conditions where multimorbidity was more strongly associated with poorer health or greater healthcare utilisation than in the remaining musculoskeletal group. Among working-age adults, for each of the specified musculoskeletal conditions, multimorbidity was associated with similar, increased likelihood of additional self-rated health burden and certain types of healthcare utilisation. While there were differences in the relationships between multimorbidity and burden for each of the specific musculoskeletal conditions, no one specific musculoskeletal condition appeared to be consistently associated with greater additional health burden in the presence of multimorbidity across the majority of self-rated health burden and healthcare use measures. For working-age people with any musculoskeletal conditions examined here, multimorbidity increases self-reported health and healthcare utilisation burden. As no one musculoskeletal condition appears consistently worse off in the presence of multimorbidity, there is a need to better understand and identify strategies that acknowledge and address the additional burden of concomitant conditions for working-age adults with a range of musculoskeletal conditions.

  8. The use of radiolabelling techniques to measure substantivity to, and penetration into, hair of protein hydrolysates.

    PubMed

    Jones, R T; Chahal, S P

    1997-10-01

    The use of 14C-labelled amino acids enables the measurement of both the total substantivity to hair and the degree of penetration into the hair shaft of amino acid mixtures derived from complete hydrolysis of proteins. The technique utilizes the fact that direct measurement of 14C radioactivity of the treated hair detects only the surface substantivity. Total substantivity can be determined following solubilization of the hair. Data obtained for wheat amino acids show significant penetration when used to treat hair from a shampoo or conditioner formulation. A similar technique has been investigated for a wheat protein partial hydrolysate using 14CNO for radiolabelling purposes and shows that significant penetration into hair can occur. L'utilisation d'amino-acides marques au 14C permet la mesure a la fois de l'absorption totale par les cheveux et du degre de penetration dans la fibre du cheveu de melanges d'amino-acides obtenus a partir d'une hydrolyse totale de proteines. La technique utilise le fait que la mesure directe de la radioactivite du 14C des cheveux traites ne detecte que l'absorption en surface. L'absorption totale peut etre determinee apres solubilisation des cheveux. Les donnees obtenues a partir d'amino-acides de ble montrent une penetration significative lors d'une utilisation pour traiter des cheveux a partir d'une formulation de shampoing ou d'apres-shampoing. Une technique similaire a ete exploree vis-a-vis d'un hydrolysat partiel d'une proteine de ble utilisant 14CNO a des fins de marquage, et montre qu'une penetration significative dans les cheveux peut avoir lieu.

  9. Glossary

    NASA Astrophysics Data System (ADS)

    Bernhardt, J. H.; Kasch, K.-U.; Kaul, A.; Kramer, H.-M.; Noßke, D.; Valentin, J.

    This document is part of Subvolume A 'Fundamentals and Data in Radiobiology, Radiation Biophysics, Dosimetry and Medical Radiological Protection' of Volume 7 'Medical Radiological Physics' of Landolt-Börnstein - Group VIII 'Advanced Materials and Technologies'. It contains the Glossary.

  10. E-Alerts: Environmental pollution and control (environmental health and safety). E-mail newsletter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Topics of discussion include the following: Effects of pollution on public health and safety; Toxicology; Industrial health; Physiology; Psychology; Clinical medicine; Radiobiology; Animals used as research experimental models.

  11. Heavy charged particle radiobiology: using enhanced biological effectiveness and improved beam focusing to advance cancer therapy.

    PubMed

    Allen, Christopher; Borak, Thomas B; Tsujii, Hirohiko; Nickoloff, Jac A

    2011-06-03

    Ionizing radiation causes many types of DNA damage, including base damage and single- and double-strand breaks. Photons, including X-rays and γ-rays, are the most widely used type of ionizing radiation in radiobiology experiments, and in radiation cancer therapy. Charged particles, including protons and carbon ions, are seeing increased use as an alternative therapeutic modality. Although the facilities needed to produce high energy charged particle beams are more costly than photon facilities, particle therapy has shown improved cancer survival rates, reflecting more highly focused dose distributions and more severe DNA damage to tumor cells. Despite early successes of charged particle radiotherapy, there is room for further improvement, and much remains to be learned about normal and cancer cell responses to charged particle radiation. 2011 Elsevier B.V. All rights reserved.

  12. [Basic principles and results of brachytherapy in gynecological oncology].

    PubMed

    Kanaev, S V; Turkevich, V G; Baranov, S B; Savel'eva, V V

    2014-01-01

    The fundamental basics of contact radiation therapy (brachytherapy) for gynecological cancer are presented. During brachytherapy the principles of conformal radiotherapy should be implemented, the aim of which is to sum the maximum possible dose of radiation to the tumor and decrease the dose load in adjacent organs and tissues, which allows reducing the frequency of radiation damage at treatment of primary tumors. It is really feasible only on modern technological level, thanks to precision topometry preparation, optimal computer dosimetrical and radiobiological planning of each session and radiotherapy in general. Successful local and long-term results of the contact radiation therapy for cancer of cervix and endometrium are due to optimal anatomical and topometrical ratio of the tumor localization, radioactive sources, and also physical and radiobiological laws of distribution and effects of ionizing radiation, the dose load accounting rules.

  13. Heavy-ion radiobiology: new approaches to delineate mechanisms underlying enhanced biological effectiveness.

    PubMed

    Blakely, E A; Kronenberg, A

    1998-11-01

    Shortly after the discovery of polonium and radium by Marie Curie and her husband and colleague, Pierre Curie, it was learned that exposure to these alpha-particle emitters produced deleterious biological effects. The mechanisms underlying the increased biological effectiveness of densely ionizing radiations, including alpha particles, neutrons and highly energetic heavy charged particles, remain an active area of investigation. In this paper, we review recent advances in several areas of the radiobiology of these densely ionizing radiations, also known as heavy ions. Advances are described in the areas of DNA damage and repair, chromosome aberrations, mutagenesis, neoplastic transformation in vitro, genomic instability, normal tissue radiobiology and carcinogenesis in vivo. We focus on technical innovations, including novel applications of pulsed-field gel electrophoresis, fluorescence in situ hybridization (FISH), linkage analysis, and studies of gene expression and protein expression. We also highlight the use of new cellular and animal systems, including those with defined DNA repair deficiencies, as well as epithelial cell model systems to assess neoplastic transformation both in vitro and in vivo. The studies reviewed herein have had a substantial impact on our understanding of the genotoxic effects of heavy ions as well as their distinct effects on tissue homeostasis. The use of these radiations in cancer therapy is also discussed. The use of both heavy-ion and proton therapy is on the upswing in several centers around the world, due to their unique energy deposition characteristics that enhance the therapeutic effect and help reduce damage to normal tissue.

  14. Heavy-ion radiobiology: new approaches to delineate mechanisms underlying enhanced biological effectiveness

    NASA Technical Reports Server (NTRS)

    Blakely, E. A.; Kronenberg, A.; Chatterjee, A. (Principal Investigator)

    1998-01-01

    Shortly after the discovery of polonium and radium by Marie Curie and her husband and colleague, Pierre Curie, it was learned that exposure to these alpha-particle emitters produced deleterious biological effects. The mechanisms underlying the increased biological effectiveness of densely ionizing radiations, including alpha particles, neutrons and highly energetic heavy charged particles, remain an active area of investigation. In this paper, we review recent advances in several areas of the radiobiology of these densely ionizing radiations, also known as heavy ions. Advances are described in the areas of DNA damage and repair, chromosome aberrations, mutagenesis, neoplastic transformation in vitro, genomic instability, normal tissue radiobiology and carcinogenesis in vivo. We focus on technical innovations, including novel applications of pulsed-field gel electrophoresis, fluorescence in situ hybridization (FISH), linkage analysis, and studies of gene expression and protein expression. We also highlight the use of new cellular and animal systems, including those with defined DNA repair deficiencies, as well as epithelial cell model systems to assess neoplastic transformation both in vitro and in vivo. The studies reviewed herein have had a substantial impact on our understanding of the genotoxic effects of heavy ions as well as their distinct effects on tissue homeostasis. The use of these radiations in cancer therapy is also discussed. The use of both heavy-ion and proton therapy is on the upswing in several centers around the world, due to their unique energy deposition characteristics that enhance the therapeutic effect and help reduce damage to normal tissue.

  15. Convex reformulation of biologically-based multi-criteria intensity-modulated radiation therapy optimization including fractionation effects

    NASA Astrophysics Data System (ADS)

    Hoffmann, Aswin L.; den Hertog, Dick; Siem, Alex Y. D.; Kaanders, Johannes H. A. M.; Huizenga, Henk

    2008-11-01

    Finding fluence maps for intensity-modulated radiation therapy (IMRT) can be formulated as a multi-criteria optimization problem for which Pareto optimal treatment plans exist. To account for the dose-per-fraction effect of fractionated IMRT, it is desirable to exploit radiobiological treatment plan evaluation criteria based on the linear-quadratic (LQ) cell survival model as a means to balance the radiation benefits and risks in terms of biologic response. Unfortunately, the LQ-model-based radiobiological criteria are nonconvex functions, which make the optimization problem hard to solve. We apply the framework proposed by Romeijn et al (2004 Phys. Med. Biol. 49 1991-2013) to find transformations of LQ-model-based radiobiological functions and establish conditions under which transformed functions result in equivalent convex criteria that do not change the set of Pareto optimal treatment plans. The functions analysed are: the LQ-Poisson-based model for tumour control probability (TCP) with and without inter-patient heterogeneity in radiation sensitivity, the LQ-Poisson-based relative seriality s-model for normal tissue complication probability (NTCP), the equivalent uniform dose (EUD) under the LQ-Poisson model and the fractionation-corrected Probit-based model for NTCP according to Lyman, Kutcher and Burman. These functions differ from those analysed before in that they cannot be decomposed into elementary EUD or generalized-EUD functions. In addition, we show that applying increasing and concave transformations to the convexified functions is beneficial for the piecewise approximation of the Pareto efficient frontier.

  16. A model to describe potential effects of chemotherapy on critical radiobiological treatments

    NASA Astrophysics Data System (ADS)

    Rodríguez-Pérez, D.; Desco, M. M.; Antoranz, J. C.

    2016-08-01

    Although chemo- and radiotherapy can annihilate tumors on their own. they are also used in coadjuvancy: improving local effects of radiotherapy using chemotherapy as a radiosensit.izer. The effects of radiotherapy are well described by current radiobiological models. The goal of this work is to describe a discrete radiotherapy model, that has been previously used describe high radiation dose response as well as unusual radio-responses of some types of tumors (e.g. prostate cancer), to obtain a model of chemo+radiotherapy that can describe how the outcome of their combination is a more efficient removal of the tumor. Our hypothesis is that, although both treatments haven different mechanisms, both affect similar key points of cell metabolism and regulation, that lead to cellular death. Hence, we will consider a discrete model where chemotherapy may affect a fraction of the same targets destroyed by radiotherapy. Although radiotherapy reaches all cells equally, chemotherapy diffuses through a tumor attaining lower concentration in its center and higher in its surface. With our simulations we study the enhanced effect of combined therapy treatment and how it depends on the tissue critical parameters (the parameters of the lion-extensive radiobiological model), the number of “targets” aimed at by chemotherapy, and the concentration and diffusion rate of the drug inside the tumor. The results show that an equivalent, cliemo-radio-dose can be computed that allows the prediction of the lower radiation dose that causes the same effect than a radio-only treatment.

  17. ‘Survival’: a simulation toolkit introducing a modular approach for radiobiological evaluations in ion beam therapy

    NASA Astrophysics Data System (ADS)

    Manganaro, L.; Russo, G.; Bourhaleb, F.; Fausti, F.; Giordanengo, S.; Monaco, V.; Sacchi, R.; Vignati, A.; Cirio, R.; Attili, A.

    2018-04-01

    One major rationale for the application of heavy ion beams in tumour therapy is their increased relative biological effectiveness (RBE). The complex dependencies of the RBE on dose, biological endpoint, position in the field etc require the use of biophysical models in treatment planning and clinical analysis. This study aims to introduce a new software, named ‘Survival’, to facilitate the radiobiological computations needed in ion therapy. The simulation toolkit was written in C++ and it was developed with a modular architecture in order to easily incorporate different radiobiological models. The following models were successfully implemented: the local effect model (LEM, version I, II and III) and variants of the microdosimetric-kinetic model (MKM). Different numerical evaluation approaches were also implemented: Monte Carlo (MC) numerical methods and a set of faster analytical approximations. Among the possible applications, the toolkit was used to reproduce the RBE versus LET for different ions (proton, He, C, O, Ne) and different cell lines (CHO, HSG). Intercomparison between different models (LEM and MKM) and computational approaches (MC and fast approximations) were performed. The developed software could represent an important tool for the evaluation of the biological effectiveness of charged particles in ion beam therapy, in particular when coupled with treatment simulations. Its modular architecture facilitates benchmarking and inter-comparison between different models and evaluation approaches. The code is open source (GPL2 license) and available at https://github.com/batuff/Survival.

  18. The effect of dose escalation on gastric toxicity when treating lower oesophageal tumours: a radiobiological investigation.

    PubMed

    Carrington, Rhys; Staffurth, John; Warren, Samantha; Partridge, Mike; Hurt, Chris; Spezi, Emiliano; Gwynne, Sarah; Hawkins, Maria A; Crosby, Thomas

    2015-11-19

    Using radiobiological modelling to estimate normal tissue toxicity, this study investigates the effects of dose escalation for concurrent chemoradiation therapy (CRT) in lower third oesophageal tumours on the stomach. 10 patients with lower third oesophageal cancer were selected from the SCOPE 1 database (ISCRT47718479) with a mean planning target volume (PTV) of 348 cm(3). The original 3D conformal plans (50 Gy3D) were compared to newly created RapidArc plans of 50 GyRA and 60 GyRA, the latter using a simultaneous integrated boost (SIB) technique using a boost volume, PTV2. Dose-volume metrics and estimates of normal tissue complication probability (NTCP) were compared. There was a significant increase in NTCP of the stomach wall when moving from the 50 GyRA to the 60 GyRA plans (11-17 %, Wilcoxon signed rank test, p = 0.01). There was a strong correlation between the NTCP values of the stomach wall and the volume of the stomach wall/PTV 1 and stomach wall/PTV2 overlap structures (R = 0.80 and R = 0.82 respectively) for the 60 GyRA plans. Radiobiological modelling suggests that increasing the prescribed dose to 60 Gy may be associated with a significantly increased risk of toxicity to the stomach. It is recommended that stomach toxicity be closely monitored when treating patients with lower third oesophageal tumours with 60 Gy.

  19. Past and Future Work on Radiobiology Mega-Studies: A Case Study At Argonne National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haley, Benjamin; Wang, Qiong; Wanzer, Beau

    2011-09-06

    Between 1952 and 1992, more than 200 large radiobiology studies were conducted in research institutes throughout Europe, North America, and Japan to determine the effects of external irradiation and internal emitters on the lifespan and tissue toxicity development in animals. At Argonne National Laboratory, 22 external beam studies were conducted on nearly 700 beagle dogs and 50,000 mice between 1969 and 1992. These studies helped to characterize the effects of neutron and gamma irradiation on lifespan, tumorigenesis, and mutagenesis across a range of doses and dosing patterns. The records and tissues collected at Argonne during that time period have beenmore » carefully preserved and redisseminated. Using these archived data, ongoing statistical work has been done and continues to characterize quality of radiation, dose, dose rate, tissue, and gender-specific differences in the radiation responses of exposed animals. The ongoing application of newly-developed molecular biology techniques to the archived tissues has revealed gene-specific mutation rates following exposure to ionizing irradiation. The original and ongoing work with this tissue archive is presented here as a case study of a more general trend in the radiobiology megastudies. These experiments helped form the modern understanding of radiation responses in animals and continue to inform development of new radiation models. Recent archival efforts have facilitated open access to the data and materials produced by these studies, and so a unique opportunity exists to expand this continued research.« less

  20. Statistical methods for clinical verification of dose response parameters related to esophageal stricture and AVM obliteration from radiotherapy

    NASA Astrophysics Data System (ADS)

    Mavroidis, Panayiotis; Lind, Bengt K.; Theodorou, Kyriaki; Laurell, Göran; Fernberg, Jan-Olof; Lefkopoulos, Dimitrios; Kappas, Constantin; Brahme, Anders

    2004-08-01

    The purpose of this work is to provide some statistical methods for evaluating the predictive strength of radiobiological models and the validity of dose-response parameters for tumour control and normal tissue complications. This is accomplished by associating the expected complication rates, which are calculated using different models, with the clinical follow-up records. These methods are applied to 77 patients who received radiation treatment for head and neck cancer and 85 patients who were treated for arteriovenous malformation (AVM). The three-dimensional dose distribution delivered to esophagus and AVM nidus and the clinical follow-up results were available for each patient. Dose-response parameters derived by a maximum likelihood fitting were used as a reference to evaluate their compatibility with the examined treatment methodologies. The impact of the parameter uncertainties on the dose-response curves is demonstrated. The clinical utilization of the radiobiological parameters is illustrated. The radiobiological models (relative seriality and linear Poisson) and the reference parameters are validated to prove their suitability in reproducing the treatment outcome pattern of the patient material studied (through the probability of finding a worse fit, area under the ROC curve and khgr2 test). The analysis was carried out for the upper 5 cm of the esophagus (proximal esophagus) where all the strictures are formed, and the total volume of AVM. The estimated confidence intervals of the dose-response curves appear to have a significant supporting role on their clinical implementation and use.

  1. The use of standardised short-term and working memory tests in aphasia research: a systematic review

    PubMed Central

    Murray, Laura; Salis, Christos; Martin, Nadine; Dralle, Jenny

    2017-01-01

    Impairments of short-term and working memory (STM, WM), both verbal and non-verbal, are ubiquitous in aphasia. Increasing interest in assessing STM and WM in aphasia research and clinical practice as well as a growing evidence base of STM/WM treatments for aphasia warrant an understanding of the range of standardised STM/WM measures that have been utilised in aphasia. To date, however, no previous systematic review has focused on aphasia. Accordingly, the goals of this systematic review were: (1) to identify standardised tests of STM and WM utilised in the aphasia literature, (2) to evaluate critically the psychometric strength of these tests, and (3) to appraise critically the quality of the investigations utilising these tests. Results revealed that a very limited number of standardised tests, in the verbal and non-verbal domains, had robust psychometric properties. Standardisation samples to elicit normative data were often small, and most measures exhibited poor validity and reliability properties. Studies using these tests inconsistently documented demographic and aphasia variables essential to interpreting STM/WM test outcomes. In light of these findings, recommendations are provided to foster, in the future, consistency across aphasia studies and confidence in STM/WM tests as assessment and treatment outcome measures. PMID:27143500

  2. The use of standardised short-term and working memory tests in aphasia research: a systematic review.

    PubMed

    Murray, Laura; Salis, Christos; Martin, Nadine; Dralle, Jenny

    2018-04-01

    Impairments of short-term and working memory (STM, WM), both verbal and non-verbal, are ubiquitous in aphasia. Increasing interest in assessing STM and WM in aphasia research and clinical practice as well as a growing evidence base of STM/WM treatments for aphasia warrant an understanding of the range of standardised STM/WM measures that have been utilised in aphasia. To date, however, no previous systematic review has focused on aphasia. Accordingly, the goals of this systematic review were: (1) to identify standardised tests of STM and WM utilised in the aphasia literature, (2) to evaluate critically the psychometric strength of these tests, and (3) to appraise critically the quality of the investigations utilising these tests. Results revealed that a very limited number of standardised tests, in the verbal and non-verbal domains, had robust psychometric properties. Standardisation samples to elicit normative data were often small, and most measures exhibited poor validity and reliability properties. Studies using these tests inconsistently documented demographic and aphasia variables essential to interpreting STM/WM test outcomes. In light of these findings, recommendations are provided to foster, in the future, consistency across aphasia studies and confidence in STM/WM tests as assessment and treatment outcome measures.

  3. Community/hospital indicators in South African public sector mental health services.

    PubMed

    Lund, Crick; Flisher, Alan J

    2003-12-01

    The need to balance resources between community and hospital-based mental health services in the post-deinstitutionalisation era has been well-documented. However, few indicators have been developed to monitor the relationship between community and hospital services, in either developed or developing countries. There is a particular need for such indicators in the South African context, with its history of inequitable services based in custodial institutions under apartheid, and a new policy that proposes the development of more equitable community-based care. Indicators are needed to measure the distribution of resources and the relative utilisation of community and hospital-based services during the reform process. These indicators are potentially useful for assessing the implementation of policy objectives over time. To develop and document community/hospital indicators in public sector mental health services in South Africa. A questionnaire was distributed to provincial mental health coordinators requesting numbers of full-time equivalent (FTE) staff who provide mental health care at all service levels, annual patient admissions to hospitals and annual patient attendances at ambulatory care facilities. The information was supplemented by consultations with mental health coordinators in each of the 9 provinces. Population data were obtained from preliminary findings of the 1996 census. The community/hospital indicator measuring staff distribution was defined as the ratio of staff employed in community settings to all staff, expressed as a percentage. The community/hospital indicator measuring patient service utilisation was defined as the ratio of the annual ambulatory care attendance rate per 100,000 population to the sum of this rate and the annual hospital admission rate per 100,000 population, expressed as a percentage. Of psychiatric public sector staff, 25% are located in community settings in South Africa (provincial range: 11-70%). If hospital outpatient services are included in the definition of ' 'hospital' ', this figure is reduced to 17% (provincial range: 3-56%). In terms of service utilisation, 66% of patient contacts with mental health services occur through ambulatory care services in South Africa (provincial range: 44-93%). Community/hospital staff distribution indicates an overemphasis on centralised hospital-based care in most provinces and inadequate hospital care in certain provinces. Patterns of patient service utilisation indicate an over-reliance on central hospital-based services and substantial unmet need. The findings draw attention to problems in information systems for mental health care in South Africa. The community/hospital indicators developed for this study form a useful measure for assessing the implementation of mental health policy over time. For the South African context, the community/hospital indicators are a measure of the extent of resource redistribution from hospital to community services and changing patterns of service utilisation over time. Currently, patterns of resource distribution and service utilisation are inconsistent with government policy. Further research is needed into the development of mental health information systems, refining service indicators and improving methodologies for assessing the implementation of mental health policies in service delivery.

  4. Health and health care utilisation among asylum seekers and refugees in the Netherlands: design of a study

    PubMed Central

    Gerritsen, Annette AM; Bramsen, Inge; Devillé, Walter; van Willigen, Loes HM; Hovens, Johannes E; van der Ploeg, Henk M

    2004-01-01

    Background This article discusses the design of a study on the prevalence of health problems (both physical and mental) and the utilisation of health care services among asylum seekers and refugees in the Netherlands, including factors that may be related to their health and their utilisation of these services. Methods/Design The study will include random samples of adult asylum seekers and refugees from Afghanistan, Iran and Somali (total planned sample of 600), as these are among the largest groups within the reception centres and municipalities in the Netherlands. The questionnaire that will be used will include questions on physical health (chronic and acute diseases and somatization), mental health (Hopkins Symptoms Checklist-25 and Harvard Trauma Questionnaire), utilisation of health care services, pre- and post-migratory traumatic experiences, life-style, acculturation, social support and socio-demographic background. The questionnaire has gone through a translation process (translation and back-translation, several checks and a pilot-study) and cross-cultural adaptation. Respondents will be interviewed by bilingual and bicultural interviewers who will be specifically trained for this purpose. This article discusses the selection of the study population, the chosen outcome measures, the translation and cross-cultural adaptation of the measurement instrument, the training of the interviewers and the practical execution of the study. The information provided may be useful for other researchers in this relatively new field of epidemiological research among various groups of asylum seekers and refugees. PMID:15070416

  5. Health and health care utilisation among asylum seekers and refugees in the Netherlands: design of a study.

    PubMed

    Gerritsen, Annette A M; Bramsen, Inge; Devillé, Walter; van Willigen, Loes H M; Hovens, Johannes E; van der Ploeg, Henk M

    2004-03-10

    This article discusses the design of a study on the prevalence of health problems (both physical and mental) and the utilisation of health care services among asylum seekers and refugees in the Netherlands, including factors that may be related to their health and their utilisation of these services. The study will include random samples of adult asylum seekers and refugees from Afghanistan, Iran and Somali (total planned sample of 600), as these are among the largest groups within the reception centres and municipalities in the Netherlands. The questionnaire that will be used will include questions on physical health (chronic and acute diseases and somatization), mental health (Hopkins Symptoms Checklist-25 and Harvard Trauma Questionnaire), utilisation of health care services, pre- and post-migratory traumatic experiences, life-style, acculturation, social support and socio-demographic background. The questionnaire has gone through a translation process (translation and back-translation, several checks and a pilot-study) and cross-cultural adaptation. Respondents will be interviewed by bilingual and bicultural interviewers who will be specifically trained for this purpose. This article discusses the selection of the study population, the chosen outcome measures, the translation and cross-cultural adaptation of the measurement instrument, the training of the interviewers and the practical execution of the study. The information provided may be useful for other researchers in this relatively new field of epidemiological research among various groups of asylum seekers and refugees.

  6. Association between secure patient–clinician email and clinical services utilisation in a US integrated health system: a retrospective cohort study

    PubMed Central

    Meng, Di; Palen, Ted E; Tsai, Joanne; McLeod, Melanie; Garrido, Terhilda; Qian, Heather

    2015-01-01

    Objective To assess associations between secure patient–clinician email use and clinical services utilisation over time. Design Retrospective cohort study between July 2010 and December 2013. Controlling for a utilisation surge around first secure email use, we analysed difference of differences between propensity score-matched groups of secure patient–clinician email users and non-users for utilisation 1–12 months before and 7–18 months after first email (users) or a randomly assigned index date (non-users). Setting US integrated healthcare delivery system. Participants 9345 adults with first secure email use between July 2011 and July 2012 and continuous enrolment for ≥30 months and 9345 adults without secure email use between July 2010 and July 2012 matched to users on demographics, health status, and baseline utilisation. Primary Outcome Measures Rates of office visits, patient-initiated phone calls, scheduled telephone visits, after-hours clinic visits, emergency department visits, and hospitalisations. Results After controlling for multiple factors, no statistically significant differences in utilisation between secure email users and non-users occurred. Utilisation transiently increased by 88–237% around first email use. Annual rates of patient-initiated phone calls decreased among secure email users, 0.2 fewer calls per person (95% CI −0.3 to −0.1), from a mean of 4.1 calls per person 1–12 months before first use to a mean of 3.8 calls per person 7–18 months after first use. Rates of patient-initiated phone calls also decreased among non-users, 0.1 fewer calls per person (95% CI −0.2 to 0.0), from a mean of 4.2 calls per person 1–12 months before the index date to mean of 4.1 calls per person 7–18 months after the index date. Conclusions Compared with non-users, patient use of secure email with clinicians was not associated with statistically significant differences in clinical services utilisation 7–18 months after first use. PMID:26553841

  7. Brief description of research papers accepted for publication during 1979. Annual report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nash, D.B

    1980-06-16

    Brief descriptions of research papers in radiobiology, biochemistry, metabolism, and biophysics published during 1979 are presented. The research was conducted by investigators in the Dept. of Radiation Biology and Biophysics. (ACR)

  8. Withstanding austerity: Equity in health services utilisation in the first stage of the economic recession in Southern Spain.

    PubMed

    Córdoba-Doña, Juan Antonio; Escolar-Pujolar, Antonio; San Sebastián, Miguel; Gustafsson, Per E

    2018-01-01

    Scant research is available on the impact of the current economic crisis and austerity policies on inequality in health services utilisation in Europe. This study aimed to describe the trends in horizontal inequity in the use of health services in Andalusia, Spain, during the early years of the Great Recession, and the contribution of demographic, economic and social factors. Consultation with a general practitioner (GP) and specialist, hospitalisation and emergency care were studied through the Andalusian Health Survey 2007 (pre-crisis) and 2011-2012 (crisis), using a composite income index as socioeconomic status (SES) indicator. Horizontal inequity indices (HII) were calculated to take differential healthcare needs into account, and a decomposition analysis of change in inequality between periods was performed. Results showed that before the crisis, the HII was positive (greater access for people with higher SES) for specialist visits but negative (greater access for people with lower SES) in the other three utilisation models. During the crisis no change was observed in inequalities in GP visits, but a pro-poor development was seen for the other types of utilisation, with hospital and emergency care showing significant inequality in favour of low income groups. Overall, the main contributors to pro-poor changes in utilisation were socio-economic variables and poor mental health, due to changes in their elasticities. Our findings show that inequalities in healthcare utilisation largely remained in favour of the less well-off, despite the cuts in welfare benefits and health services provision during the early years of the recession in Andalusia. Further research is needed to monitor the potential impact of such measures in subsequent years.

  9. Withstanding austerity: Equity in health services utilisation in the first stage of the economic recession in Southern Spain

    PubMed Central

    2018-01-01

    Scant research is available on the impact of the current economic crisis and austerity policies on inequality in health services utilisation in Europe. This study aimed to describe the trends in horizontal inequity in the use of health services in Andalusia, Spain, during the early years of the Great Recession, and the contribution of demographic, economic and social factors. Consultation with a general practitioner (GP) and specialist, hospitalisation and emergency care were studied through the Andalusian Health Survey 2007 (pre-crisis) and 2011–2012 (crisis), using a composite income index as socioeconomic status (SES) indicator. Horizontal inequity indices (HII) were calculated to take differential healthcare needs into account, and a decomposition analysis of change in inequality between periods was performed. Results showed that before the crisis, the HII was positive (greater access for people with higher SES) for specialist visits but negative (greater access for people with lower SES) in the other three utilisation models. During the crisis no change was observed in inequalities in GP visits, but a pro-poor development was seen for the other types of utilisation, with hospital and emergency care showing significant inequality in favour of low income groups. Overall, the main contributors to pro-poor changes in utilisation were socio-economic variables and poor mental health, due to changes in their elasticities. Our findings show that inequalities in healthcare utilisation largely remained in favour of the less well-off, despite the cuts in welfare benefits and health services provision during the early years of the recession in Andalusia. Further research is needed to monitor the potential impact of such measures in subsequent years. PMID:29601609

  10. Measurement of inequity in health care with heterogeneous response of use to need.

    PubMed

    Van de Poel, Ellen; Van Doorslaer, Eddy; O'Donnell, Owen

    2012-07-01

    We propose a method of measuring and decomposing inequity in health care utilisation that allows for heterogeneity in the use-need relationship. This makes explicit inequity that derives from unequal treatment response to variation in need, as well as that due to differential effects of non-need determinants. Under plausible conditions concerning heterogeneity in the use-need relationship and the distribution of need, existing methods that impose homogeneity will underestimate pro-rich inequity. This prediction is confirmed for four middle-income Asian countries. In those countries, around one half of the observed socioeconomic inequality is due to utilisation being more responsive to need among the higher wealth and urban dwelling individuals. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Brachytherapy optimization using radiobiological-based planning for high dose rate and permanent implants for prostate cancer treatment

    NASA Astrophysics Data System (ADS)

    Seeley, Kaelyn; Cunha, J. Adam; Hong, Tae Min

    2017-01-01

    We discuss an improvement in brachytherapy--a prostate cancer treatment method that directly places radioactive seeds inside target cancerous regions--by optimizing the current standard for delivering dose. Currently, the seeds' spatiotemporal placement is determined by optimizing the dose based on a set of physical, user-defined constraints. One particular approach is the ``inverse planning'' algorithms that allow for tightly fit isodose lines around the target volumes in order to reduce dose to the patient's organs at risk. However, these dose distributions are typically computed assuming the same biological response to radiation for different types of tissues. In our work, we consider radiobiological parameters to account for the differences in the individual sensitivities and responses to radiation for tissues surrounding the target. Among the benefits are a more accurate toxicity rate and more coverage to target regions for planning high-dose-rate treatments as well as permanent implants.

  12. BASIC RADIATION PROTECTION EDUCATION AND TRAINING FOR MEDICAL PROFESSIONALS; GEORGIAN EXPERIENCE AND FUTURE PERSPECTIVE.

    PubMed

    Todua, F; Nadareishvili, D; Ormotsadze, G; Sanikidze, T

    2016-06-01

    The level of knowledge provided by the Tbilisi State Medical University (TSMU) standard curriculum modules in 'Medical physics' and 'Radiation risk estimates' was assessed as was the learning outcome of modern standards elective course in 'Radiation protection'. Two groups of medical students were examined: Group 1: 5 y students, participants in elective course 'Radiobiology and radiogenic health risk' and Group 2: 1-2 y students, participants in winter and summer schools. Students were tested before and after training courses with the same tests questionnaire. The results of the tests showed the necessity for improvement of the educational curriculum. The changes needed are the inclusion of a basic radiobiological course in the curricula of the faculty of medicine and expansion of the medical physics course through a more detailed presentation of medical imaging methods. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. [Medical and biological consequences of nuclear disasters].

    PubMed

    Stalpers, Lukas J A; van Dullemen, Simon; Franken, N A P Klaas

    2012-01-01

    Medical risks of radiation exaggerated; psychological risks underestimated. The discussion about atomic energy has become topical again following the nuclear accident in Fukushima. There is some argument about the gravity of medical and biological consequences of prolonged exposure to radiation. The risk of cancer following a low dose of radiation is usually estimated by linear extrapolation of the incidence of cancer among survivors of the atomic bombs dropped on Hiroshima and Nagasaki in 1945. The radiobiological linear-quadratic model (LQ-model) gives a more accurate description of observed data, is radiobiologically more plausible and is better supported by experimental and clinical data. On the basis of this model there is less risk of cancer being induced following radiation exposure. The gravest consequence of Chernobyl and Fukushima is not the medical and biological damage, but the psychological and economical impact on rescue workers and former inhabitants.

  14. Information on radiation hazard and on radiological protection in medical school in Italy.

    PubMed

    Biagini, C

    1993-04-01

    The state of teaching Radiation Protection in Medical School in Italy was considered. An historical approach was utilized, in order to define periods of time characterized by different conditions. Some data are collected by a concise enquiry on the information given during the course of Radiology in the second triennal cycle, and on some other teaching courses including information on radiation effects. The conclusion is that teaching times are exceedingly reduced, and the need of improving the diffusion of knowledge in the field is stressed. An official Act of the OECD and of European Community is expected, with the aim of emphasizing the importance of the information of doctors on Radiation protection as a problem of public interest. A proposal is advanced of implementing the Teaching of Radiobiology in the second triennal cycle, changing the name of the course in "Radiobiology and Radiological Protection".

  15. Tracks to therapy

    NASA Technical Reports Server (NTRS)

    Katz, R.; Cucinotta, F. A.

    1999-01-01

    Studies of the structure of particle tracks have led to models of track effects based on radial dose and radiobiological target theory that have been very successful in describing and predicting track effects in physical, chemical, and biological systems. For describing mammalian cellular inactivation two inactivation modes are required, called gamma-kill and ion-kill, the first due to synergistic effects of delta rays from adjacent ion paths thus resembling the effects from gamma rays, and the second to the effects of single ion transits through a cell nucleus. The ion-kill effect is more severe, where the fraction of cells experiencing ion kill is responsible for a decrease in the oxygen enhancement ratio, and an increase in relative biological effectiveness, but these are accompanied by loss of repair, hence to a reduction in the efficiency of fractionation in high LET therapy, as shown by our calculations for radiobiological effects in the "spread out Bragg Peak".

  16. Radiobiological studies with the nematode Caenorhabditis elegans. Genetic and developmental effects of high LET radiation

    NASA Technical Reports Server (NTRS)

    Nelson, G. A.; Schubert, W. W.; Marshall, T. M.

    1992-01-01

    The biological effects of heavy charged particle (HZE) radiation are of particular interest to travellers and planners for long-duration space flights where exposure levels represent a potential health hazard. The unique feature of HZE radiation is the structured pattern of its energy deposition in targets. There are many consequences of this feature to biological endpoints when compared with effects of ionizing photons. Dose vs response and dose-rate kinetics may be modified, DNA and cellular repair systems may be altered in their abilities to cope with damage, and the qualitative features of damage may be unique for different ions. The nematode Caenorhabditis elegans is being used to address these and related questions associated with exposure to radiation. HZE-induced mutation, chromosome aberration, cell inactivation and altered organogenesis are discussed along with plans for radiobiological experiments in space.

  17. Residential respite care is associated with family carers experiencing financial strain.

    PubMed

    Aggar, Christina; Ronaldson, Susan; Cameron, Ian D

    2014-06-01

    Care services for older people are provided with the expectation of supporting carers in their caregiving role. The aim of the study is to investigate the association between the utilisation of care services by older people and the caregiving experience. Cross-sectional design, involving a cohort of family carers (n = 119) of frail older people (≥70 years) enrolled in a clinical trial of frailty treatment in metropolitan Sydney from 2008 to 2011. The caregiving experience was measured in five domains: health, daily schedule, finance, family support and self-esteem (Caregiver Reaction Assessment tool). Multivariate regression analysis demonstrated an association between the utilisation of residential respite care and financial strain (β = -0.613, P = 0.049), after controlling for functional ability, co-residence and age. There is a need to consider carers' financial barriers and concerns in regards to the utilisation of respite care services. © 2012 The Authors. Australasian Journal on Ageing © 2012 ACOTA.

  18. Nanodosimetric track structure in homogeneous extended beams.

    PubMed

    Conte, V; Moro, D; Colautti, P; Grosswendt, B

    2015-09-01

    Physical aspects of particle track structure are important in determining the induction of clustered damage in relevant subcellular structures like the DNA and higher-order genomic structures. The direct measurement of track-structure properties of ionising radiation is feasible today by counting the number of ionisations produced inside a small gas volume. In particular, the so-called track-nanodosimeter, installed at the TANDEM-ALPI accelerator complex of LNL, measures ionisation cluster-size distributions in a simulated subcellular structure of dimensions 20 nm, corresponding approximately to the diameter of the chromatin fibre. The target volume is irradiated by pencil beams of primary particles passing at specified impact parameter. To directly relate these measured track-structure data to radiobiological measurements performed in broad homogeneous particle beams, these data can be integrated over the impact parameter. This procedure was successfully applied to 240 MeV carbon ions and compared with Monte Carlo simulations for extended fields. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Fallout from the Chernobyl nuclear disaster and congenital malformations in Europe.

    PubMed

    Hoffmann, W

    2001-01-01

    Investigators estimate that the population exposure that resulted from the Chernobyl fallout is in the range of natural background radiation for most European countries. Given current radiobiologic knowledge, health effects-if any-would not be measurable with epidemiologic tools. In several independent reports, however, researchers have described isolated peaks in the prevalence of congenital malformations in the cohort conceived immediately after onset of the fallout. The consistency of the time pattern and the specific types of malformation raise concern about their significance. In this study, the author summarizes findings from Turkey, Belarus, Croatia, Finland, Germany, and other countries, and implications for radiation protection and public health issues are discussed.

  20. A national appraisal of haemodialysis vascular access provision in Scotland.

    PubMed

    Oliver, Scott W; Campbell, Jacqueline; Kingsmore, David B; Kasthuri, Ram; Metcalfe, Wendy; Traynor, Jamie P; Fischbacher-Smith, Denis; Jardine, Alan G; Thomson, Peter C

    2017-03-21

    Published registry data demonstrate longstanding variation in the utilisation of different vascular access (VA) modalities between Scottish renal units; this may reflect different clinical processes between centres. A comprehensive appraisal was undertaken to understand the processes underpinning VA creation and maintenance across Scotland. A mixed methods approach was utilised. Fifty-two semi-structured interviews were conducted with patients and clinicians in all ten, adult and paediatric, Scottish renal units. Interview transcripts were subjected to thematic analysis. Clinical activity data were prospectively collected for six weeks, and correlated with registry data. VA accounts for a large clinical workload. There was significant inter-centre variation in the utilisation of different VA modalities, and patients described frustrating, dissatisfying experiences. VA creation and maintenance pathways functioned best when nephrologists, surgeons and radiologists were co-located on the same campus with close multi-disciplinary working, protected clinical time, and proactive VA maintenance. No unit routinely measured or discussed procedure outcomes or strategic aspects of their service. Varied clinical outcomes reflected varied clinical processes. Optimised clinical pathways, staff education and measurement of clinical outcomes may improve VA service quality and facilitate safer, more effective, patient-centred care.

  1. Dosimetry and radiobiology at the new RA-3 reactor boron neutron capture therapy (BNCT) facility: application to the treatment of experimental oral cancer.

    PubMed

    Pozzi, E; Nigg, D W; Miller, M; Thorp, S I; Heber, E M; Zarza, L; Estryk, G; Monti Hughes, A; Molinari, A J; Garabalino, M; Itoiz, M E; Aromando, R F; Quintana, J; Trivillin, V A; Schwint, A E

    2009-07-01

    The National Atomic Energy Commission of Argentina (CNEA) constructed a novel thermal neutron source for use in boron neutron capture therapy (BNCT) applications at the RA-3 research reactor facility located in Buenos Aires. The aim of the present study was to perform a dosimetric characterization of the facility and undertake radiobiological studies of BNCT in an experimental model of oral cancer in the hamster cheek pouch. The free-field thermal flux was 7.1 x 10(9) n cm(-2)s(-1) and the fast neutron flux was 2.5 x 10(6) n cm(-2)s(-1), indicating a very well-thermalized neutron field with negligible fast neutron dose. For radiobiological studies it was necessary to shield the body of the hamster from the neutron flux while exposing the everted cheek pouch bearing the tumors. To that end we developed a lithium (enriched to 95% in (6)Li) carbonate enclosure. Groups of tumor-bearing hamsters were submitted to BPA-BNCT, GB-10-BNCT, (GB-10+BPA)-BNCT or beam only treatments. Normal (non-cancerized) hamsters were treated similarly to evaluate normal tissue radiotoxicity. The total physical dose delivered to tumor with the BNCT treatments ranged from 6 to 8.5 Gy. Tumor control at 30 days ranged from 73% to 85%, with no normal tissue radiotoxicity. Significant but reversible mucositis in precancerous tissue surrounding tumors was associated to BPA-BNCT. The therapeutic success of different BNCT protocols in treating experimental oral cancer at this novel facility was unequivocally demonstrated.

  2. A novel algorithm for the calculation of physical and biological irradiation quantities in scanned ion beam therapy: the beamlet superposition approach

    NASA Astrophysics Data System (ADS)

    Russo, G.; Attili, A.; Battistoni, G.; Bertrand, D.; Bourhaleb, F.; Cappucci, F.; Ciocca, M.; Mairani, A.; Milian, F. M.; Molinelli, S.; Morone, M. C.; Muraro, S.; Orts, T.; Patera, V.; Sala, P.; Schmitt, E.; Vivaldo, G.; Marchetto, F.

    2016-01-01

    The calculation algorithm of a modern treatment planning system for ion-beam radiotherapy should ideally be able to deal with different ion species (e.g. protons and carbon ions), to provide relative biological effectiveness (RBE) evaluations and to describe different beam lines. In this work we propose a new approach for ion irradiation outcomes computations, the beamlet superposition (BS) model, which satisfies these requirements. This model applies and extends the concepts of previous fluence-weighted pencil-beam algorithms to quantities of radiobiological interest other than dose, i.e. RBE- and LET-related quantities. It describes an ion beam through a beam-line specific, weighted superposition of universal beamlets. The universal physical and radiobiological irradiation effect of the beamlets on a representative set of water-like tissues is evaluated once, coupling the per-track information derived from FLUKA Monte Carlo simulations with the radiobiological effectiveness provided by the microdosimetric kinetic model and the local effect model. Thanks to an extension of the superposition concept, the beamlet irradiation action superposition is applicable for the evaluation of dose, RBE and LET distributions. The weight function for the beamlets superposition is derived from the beam phase space density at the patient entrance. A general beam model commissioning procedure is proposed, which has successfully been tested on the CNAO beam line. The BS model provides the evaluation of different irradiation quantities for different ions, the adaptability permitted by weight functions and the evaluation speed of analitical approaches. Benchmarking plans in simple geometries and clinical plans are shown to demonstrate the model capabilities.

  3. Tumor-volume simulation during radiotherapy for head-and-neck cancer using a four-level cell population model.

    PubMed

    Chvetsov, Alexei V; Dong, Lei; Palta, Jantinder R; Amdur, Robert J

    2009-10-01

    To develop a fast computational radiobiologic model for quantitative analysis of tumor volume during fractionated radiotherapy. The tumor-volume model can be useful for optimizing image-guidance protocols and four-dimensional treatment simulations in proton therapy that is highly sensitive to physiologic changes. The analysis is performed using two approximations: (1) tumor volume is a linear function of total cell number and (2) tumor-cell population is separated into four subpopulations: oxygenated viable cells, oxygenated lethally damaged cells, hypoxic viable cells, and hypoxic lethally damaged cells. An exponential decay model is used for disintegration and removal of oxygenated lethally damaged cells from the tumor. We tested our model on daily volumetric imaging data available for 14 head-and-neck cancer patients treated with an integrated computed tomography/linear accelerator system. A simulation based on the averaged values of radiobiologic parameters was able to describe eight cases during the entire treatment and four cases partially (50% of treatment time) with a maximum 20% error. The largest discrepancies between the model and clinical data were obtained for small tumors, which may be explained by larger errors in the manual tumor volume delineation procedure. Our results indicate that the change in gross tumor volume for head-and-neck cancer can be adequately described by a relatively simple radiobiologic model. In future research, we propose to study the variation of model parameters by fitting to clinical data for a cohort of patients with head-and-neck cancer and other tumors. The potential impact of other processes, like concurrent chemotherapy, on tumor volume should be evaluated.

  4. Identifying patterns of general practitioner service utilisation and their relationship with potentially preventable hospitalisations in people with diabetes: The utility of a cluster analysis approach.

    PubMed

    Ha, Ninh Thi; Harris, Mark; Preen, David; Robinson, Suzanne; Moorin, Rachael

    2018-04-01

    We aimed to characterise use of general practitioners (GP) simultaneously across multiple attributes in people with diabetes and examine its impact on diabetes related potentially preventable hospitalisations (PPHs). Five-years of panel data from 40,625 adults with diabetes were sourced from Western Australian administrative health records. Cluster analysis (CA) was used to group individuals with similar patterns of GP utilisation characterised by frequency and recency of services. The relationship between GP utilisation cluster and the risk of PPHs was examined using multivariable random-effects negative binomial regression. CA categorised GP utilisation into three clusters: moderate; high and very high usage, having distinct patient characteristics. After adjusting for potential confounders, the rate of PPHs was significantly lower across all GP usage clusters compared with those with no GP usage; IRR = 0.67 (95%CI: 0.62-0.71) among the moderate, IRR = 0.70 (95%CI 0.66-0.73) high and IRR = 0.76 (95%CI 0.72-0.80) very high GP usage clusters. Combination of temporal factors with measures of frequency of use of GP services revealed patterns of primary health care utilisation associated with different underlying patient characteristics. Incorporation of multiple attributes, that go beyond frequency-based approaches may better characterise the complex relationship between use of GP services and diabetes-related hospitalisation. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Apelin targets gut contraction to control glucose metabolism via the brain

    PubMed Central

    Fournel, Audren; Drougard, Anne; Duparc, Thibaut; Marlin, Alysson; Brierley, Stuart M; Castro, Joel; Le-Gonidec, Sophie; Masri, Bernard; Colom, André; Lucas, Alexandre; Rousset, Perrine; Cenac, Nicolas; Vergnolle, Nathalie; Valet, Philippe; Cani, Patrice D; Knauf, Claude

    2017-01-01

    Objective The gut–brain axis is considered as a major regulatory checkpoint in the control of glucose homeostasis. The detection of nutrients and/or hormones in the duodenum informs the hypothalamus of the host's nutritional state. This process may occur via hypothalamic neurons modulating central release of nitric oxide (NO), which in turn controls glucose entry into tissues. The enteric nervous system (ENS) modulates intestinal contractions in response to various stimuli, but the importance of this interaction in the control of glucose homeostasis via the brain is unknown. We studied whether apelin, a bioactive peptide present in the gut, regulates ENS-evoked contractions, thereby identifying a new physiological partner in the control of glucose utilisation via the hypothalamus. Design We measured the effect of apelin on electrical and mechanical duodenal responses via telemetry probes and isotonic sensors in normal and obese/diabetic mice. Changes in hypothalamic NO release, in response to duodenal contraction modulated by apelin, were evaluated in real time with specific amperometric probes. Glucose utilisation in tissues was measured with orally administrated radiolabeled glucose. Results In normal and obese/diabetic mice, glucose utilisation is improved by the decrease of ENS/contraction activities in response to apelin, which generates an increase in hypothalamic NO release. As a consequence, glucose entry is significantly increased in the muscle. Conclusions Here, we identify a novel mode of communication between the intestine and the hypothalamus that controls glucose utilisation. Moreover, our data identified oral apelin administration as a novel potential target to treat metabolic disorders. PMID:26565000

  6. Provisional standards of radiation safety during flights

    NASA Technical Reports Server (NTRS)

    1977-01-01

    Radiation effects during space flights are discussed in the context of the sources and dangers of such radiation and the radiobiological prerequisites for establishing safe levels of radiation dosage. Standard safe levels of radiation during space flight are established.

  7. Neutron therapy of cancer

    NASA Technical Reports Server (NTRS)

    Frigerio, N. A.; Nellans, H. N.; Shaw, M. J.

    1969-01-01

    Reports relate applications of neutrons to the problem of cancer therapy. The biochemical and biophysical aspects of fast-neutron therapy, neutron-capture and neutron-conversion therapy with intermediate-range neutrons are presented. Also included is a computer program for neutron-gamma radiobiology.

  8. [The SILENE reactor: a tool adapted for applied study of moderate and large doses].

    PubMed

    Verrey, B; Leo, Y; Fouillaud, P

    2002-07-01

    Designed in 1974 to study the phenomenology and consequences of a critical accident, the SILENE experimental reactor, an intense source of mixed neutron and gamma radiation, is also suited to radiobiological studies.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Brief summaries are presented of research in progress in the fields of radiobiology, genetics, hematology, immunology physiology. biochemistry, bacteriology, enzymology, microbiology, photosynthesis, biophysics, radiation protection, and related fields. A list is included of 240 publications in the world literature that report results of completed studies. (CH)

  10. The Australian Racism, Acceptance, and Cultural-Ethnocentrism Scale (RACES): item response theory findings.

    PubMed

    Grigg, Kaine; Manderson, Lenore

    2016-03-17

    Racism and associated discrimination are pervasive and persistent challenges with multiple cumulative deleterious effects contributing to inequities in various health outcomes. Globally, research over the past decade has shown consistent associations between racism and negative health concerns. Such research confirms that race endures as one of the strongest predictors of poor health. Due to the lack of validated Australian measures of racist attitudes, RACES (Racism, Acceptance, and Cultural-Ethnocentrism Scale) was developed. Here, we examine RACES' psychometric properties, including the latent structure, utilising Item Response Theory (IRT). Unidimensional and Multidimensional Rating Scale Model (RSM) Rasch analyses were utilised with 296 Victorian primary school students and 182 adolescents and 220 adults from the Australian community. RACES was demonstrated to be a robust 24-item three-dimensional scale of Accepting Attitudes (12 items), Racist Attitudes (8 items), and Ethnocentric Attitudes (4 items). RSM Rasch analyses provide strong support for the instrument as a robust measure of racist attitudes in the Australian context, and for the overall factorial and construct validity of RACES across primary school children, adolescents, and adults. RACES provides a reliable and valid measure that can be utilised across the lifespan to evaluate attitudes towards all racial, ethnic, cultural, and religious groups. A core function of RACES is to assess the effectiveness of interventions to reduce community levels of racism and in turn inequities in health outcomes within Australia.

  11. Utilisation of rheumatology care services in Germany: the case of physical therapy and self-help groups.

    PubMed

    Thieme, Holm; Borgetto, Bernhard

    2012-01-01

    Physical Therapy (PT) and self-help groups (SHG) are important components of health care in rheumatic diseases. The utilisation of PT and SHG by patients with rheumatic diseases may be influenced by several factors. The aim of this study is to summarize the evidence on PT and SHG utilisation of patients with rheumatic diseases in Germany. We systematically searched the MEDLINE-database for studies that evaluated the utilisation and factors that possibly influence the utilisation of PT and SHG. Eight studies were found for PT-utilisation and one for SHG-utilisation. Between 25 and 59 percent of patients with rheumatic diseases received PT services. Several individual and contextual factors that may influence the utilisation could be identified. In conclusion, evidence exists for wide variations in the utilisation of PT services and an underuse of such services among patients with rheumatic diseases in Germany. By contrast, little evidence exists on the utilisation of SHG.

  12. The alfa and beta of tumours: a review of parameters of the linear-quadratic model, derived from clinical radiotherapy studies.

    PubMed

    van Leeuwen, C M; Oei, A L; Crezee, J; Bel, A; Franken, N A P; Stalpers, L J A; Kok, H P

    2018-05-16

    Prediction of radiobiological response is a major challenge in radiotherapy. Of several radiobiological models, the linear-quadratic (LQ) model has been best validated by experimental and clinical data. Clinically, the LQ model is mainly used to estimate equivalent radiotherapy schedules (e.g. calculate the equivalent dose in 2 Gy fractions, EQD 2 ), but increasingly also to predict tumour control probability (TCP) and normal tissue complication probability (NTCP) using logistic models. The selection of accurate LQ parameters α, β and α/β is pivotal for a reliable estimate of radiation response. The aim of this review is to provide an overview of published values for the LQ parameters of human tumours as a guideline for radiation oncologists and radiation researchers to select appropriate radiobiological parameter values for LQ modelling in clinical radiotherapy. We performed a systematic literature search and found sixty-four clinical studies reporting α, β and α/β for tumours. Tumour site, histology, stage, number of patients, type of LQ model, radiation type, TCP model, clinical endpoint and radiobiological parameter estimates were extracted. Next, we stratified by tumour site and by tumour histology. Study heterogeneity was expressed by the I 2 statistic, i.e. the percentage of variance in reported values not explained by chance. A large heterogeneity in LQ parameters was found within and between studies (I 2  > 75%). For the same tumour site, differences in histology partially explain differences in the LQ parameters: epithelial tumours have higher α/β values than adenocarcinomas. For tumour sites with different histologies, such as in oesophageal cancer, the α/β estimates correlate well with histology. However, many other factors contribute to the study heterogeneity of LQ parameters, e.g. tumour stage, type of LQ model, TCP model and clinical endpoint (i.e. survival, tumour control and biochemical control). The value of LQ parameters for tumours as published in clinical radiotherapy studies depends on many clinical and methodological factors. Therefore, for clinical use of the LQ model, LQ parameters for tumour should be selected carefully, based on tumour site, histology and the applied LQ model. To account for uncertainties in LQ parameter estimates, exploring a range of values is recommended.

  13. Towards a Clinical Decision Support System for External Beam Radiation Oncology Prostate Cancer Patients: Proton vs. Photon Radiotherapy? A Radiobiological Study of Robustness and Stability

    PubMed Central

    Walsh, Seán; Roelofs, Erik; Kuess, Peter; van Wijk, Yvonka; Lambin, Philippe; Jones, Bleddyn; Verhaegen, Frank

    2018-01-01

    We present a methodology which can be utilized to select proton or photon radiotherapy in prostate cancer patients. Four state-of-the-art competing treatment modalities were compared (by way of an in silico trial) for a cohort of 25 prostate cancer patients, with and without correction strategies for prostate displacements. Metrics measured from clinical image guidance systems were used. Three correction strategies were investigated; no-correction, extended-no-action-limit, and online-correction. Clinical efficacy was estimated via radiobiological models incorporating robustness (how probable a given treatment plan was delivered) and stability (the consistency between the probable best and worst delivered treatments at the 95% confidence limit). The results obtained at the cohort level enabled the determination of a threshold for likely clinical benefit at the individual level. Depending on the imaging system and correction strategy; 24%, 32% and 44% of patients were identified as suitable candidates for proton therapy. For the constraints of this study: Intensity-modulated proton therapy with online-correction was on average the most effective modality. Irrespective of the imaging system, each treatment modality is similar in terms of robustness, with and without the correction strategies. Conversely, there is substantial variation in stability between the treatment modalities, which is greatly reduced by correction strategies. This study provides a ‘proof-of-concept’ methodology to enable the prospective identification of individual patients that will most likely (above a certain threshold) benefit from proton therapy. PMID:29463018

  14. Laser-driven particle acceleration for radiobiology and radiotherapy: where we are and where we are going

    NASA Astrophysics Data System (ADS)

    Giulietti, Antonio

    2017-05-01

    Radiation therapy of tumors progresses continuously and so do devices, sharing a global market of about $ 4 billions, growing at an annual rate exceeding 5%. Most of the progress involves tumor targeting, multi-beam irradiation, reduction of damage on healthy tissues and critical organs, dose fractioning. This fast-evolving scenario is the moving benchmark for the progress of the laser-based accelerators towards clinical uses. As for electrons, both energy and dose requested by radiotherapy are available with plasma accelerators driven by lasers in the power range of tens of TW but several issues have still to be faced before getting a prototype device for clinical tests. They include capability of varying electron energy, stability of the process, reliability for medical users. On the other side hadron therapy, presently applied to a small fraction of cases but within an exponential growth, is a primary option for the future. With such a strong motivation, research on laser-based proton/ion acceleration has been supported in the last decade in order to get performances suitable to clinical standards. None of these performances has been achieved so far with laser techniques. In the meantime a rich crop of data have been obtained in radiobiological experiments performed with beams of particles produced with laser techniques. It is quite significant however that most of the experiments have been performed moving bio samples to laser labs, rather moving laser equipment to bio labs or clinical contexts. This give us the measure that laser community cannot so far provide practical devices usable by non-laser people.

  15. Comparison of electromagnetic and hadronic models generated using Geant 4 with antiproton dose measured in CERN.

    PubMed

    Tavakoli, Mohammad Bagher; Reiazi, Reza; Mohammadi, Mohammad Mehdi; Jabbari, Keyvan

    2015-01-01

    After proposing the idea of antiproton cancer treatment in 1984 many experiments were launched to investigate different aspects of physical and radiobiological properties of antiproton, which came from its annihilation reactions. One of these experiments has been done at the European Organization for Nuclear Research known as CERN using the antiproton decelerator. The ultimate goal of this experiment was to assess the dosimetric and radiobiological properties of beams of antiprotons in order to estimate the suitability of antiprotons for radiotherapy. One difficulty on this way was the unavailability of antiproton beam in CERN for a long time, so the verification of Monte Carlo codes to simulate antiproton depth dose could be useful. Among available simulation codes, Geant4 provides acceptable flexibility and extensibility, which progressively lead to the development of novel Geant4 applications in research domains, especially modeling the biological effects of ionizing radiation at the sub-cellular scale. In this study, the depth dose corresponding to CERN antiproton beam energy by Geant4 recruiting all the standard physics lists currently available and benchmarked for other use cases were calculated. Overall, none of the standard physics lists was able to draw the antiproton percentage depth dose. Although, with some models our results were promising, the Bragg peak level remained as the point of concern for our study. It is concluded that the Bertini model with high precision neutron tracking (QGSP_BERT_HP) is the best to match the experimental data though it is also the slowest model to simulate events among the physics lists.

  16. OPERATION CROSSROADS. A COMPARISON OF THE EFFECTS OF TEST ABLE ATOMIC BOMB IONIZING RADIATION AND X-RAYS ON SEEDS OF BARLEY, WHEAT AND OATS.

    DTIC Science & Technology

    SEEDS ), (*RADIATION EFFECTS, (*NUCLEAR EXPLOSIONS, RADIATION HAZARDS), X RAYS, WHEAT, RADIATION DOSAGE, MUTATIONS, RADIOBIOLOGY, GROWTH(PHYSIOLOGY), CEREALS, SENSITIVITY, AGING(PHYSIOLOGY), EXPERIMENTAL DATA, NUCLEAR BOMBS.

  17. Introductory Laboratory Exercises in Radiobiology

    ERIC Educational Resources Information Center

    Williams, J. R. Parry; Servant, D. M.

    1970-01-01

    Describes experiments suitable for introducing use of radioisotopes in biology. Includes demonstrations of tracing food chains, uptake of ions by plants, concentration of elements by insects, tracing photosynthetic reactions, activation analysis of copper, and somatic and genetic effects. Uses autoradiographic and counting techniques. (AL)

  18. Cosmic heavy ion tracks in mesoscopic biological test objects

    NASA Technical Reports Server (NTRS)

    Facius, R.

    1994-01-01

    Since more than 20 years ago, when the National Academy of Sciences and the National Research Council of the U.S.A. released their report on 'HZE particle effects in manned spaced flight', it has been emphasized how difficult - if not even impossible - it is to assess their radiobiological impact on man from conventional studies where biological test organisms are stochastically exposed to 'large' fluences of heavy ions. An alternative, competing approach had been realized in the BIOSTACK experiments, where the effects of single cosmic as well as accelerator - heavy ions on individual biological test organisms could be investigated. Although presented from the beginning as the preferable approach for terrestrial investigations with accelerator heavy ions too ('The BIOSTACK as an approach to high LET radiation research'), only recently this insight is gaining more widespread recognition. In space flight experiments, additional constraints imposed by the infrastructure of the vehicle or satellite further impede such investigations. Restrictions concern the physical detector systems needed for the registration of the cosmic heavy ions' trajectories as well as the biological systems eligible as test organisms. Such optimized procedures and techniques were developed for the investigations on chromosome aberrations induced by cosmic heavy ions in cells of the stem meristem of lettuce seeds (Lactuca sativa) and for the investigation of the radiobiological response of Wolffia arriza, which is the smallest flowering (water) plant. The biological effects were studied by the coworkers of the Russian Institute of Biomedical Problems (IBMP) which in cooperation with the European Space Agency ESA organized the exposure in the Biosatellites of the Cosmos series. Since biological investigations and physical measurements of particle tracks had to be performed in laboratories widely separated, the preferred fixed contact between biological test objects and the particle detectors until the geometrical correlation between tracks and organisms has been established could not be maintained. This gave rise to half a dozen of coordinate systems for different measurements which finally had to be related to a single stack reference system.

  19. SU-E-T-429: Uncertainties of Cell Surviving Fractions Derived From Tumor-Volume Variation Curves

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chvetsov, A

    2014-06-01

    Purpose: To evaluate uncertainties of cell surviving fraction reconstructed from tumor-volume variation curves during radiation therapy using sensitivity analysis based on linear perturbation theory. Methods: The time dependent tumor-volume functions V(t) have been calculated using a twolevel cell population model which is based on the separation of entire tumor cell population in two subpopulations: oxygenated viable and lethally damaged cells. The sensitivity function is defined as S(t)=[δV(t)/V(t)]/[δx/x] where δV(t)/V(t) is the time dependent relative variation of the volume V(t) and δx/x is the relative variation of the radiobiological parameter x. The sensitivity analysis was performed using direct perturbation method wheremore » the radiobiological parameter x was changed by a certain error and the tumor-volume was recalculated to evaluate the corresponding tumor-volume variation. Tumor volume variation curves and sensitivity functions have been computed for different values of cell surviving fractions from the practically important interval S{sub 2}=0.1-0.7 using the two-level cell population model. Results: The sensitivity functions of tumor-volume to cell surviving fractions achieved a relatively large value of 2.7 for S{sub 2}=0.7 and then approached zero as S{sub 2} is approaching zero Assuming a systematic error of 3-4% we obtain that the relative error in S{sub 2} is less that 20% in the range S2=0.4-0.7. This Resultis important because the large values of S{sub 2} are associated with poor treatment outcome should be measured with relatively small uncertainties. For the very small values of S2<0.3, the relative error can be larger than 20%; however, the absolute error does not increase significantly. Conclusion: Tumor-volume curves measured during radiotherapy can be used for evaluation of cell surviving fractions usually observed in radiation therapy with conventional fractionation.« less

  20. SU-G-TeP3-02: Determination of Geometry-Specific Backscatter Factors for Radiobiology Studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Viscariello, N; Culberson, W; Lawless, M

    2016-06-15

    Purpose: Radiation biology research relies on an accurate radiation dose delivered to the biological target. Large field irradiations in a cabinet irradiator may use the AAPM TG-61 protocol. This relies on an air-kerma measurement and conversion to absorbed dose to water (Dw) on the surface of a water phantom using provided backscatter factors. Cell or small animal studies differ significantly from this reference geometry. This study aims to determine the impact of the lack of full scatter conditions in four representative geometries that may be used in radiobiology studies. Methods: MCNP6 was used to model the Dw on the surfacemore » of a full scatter phantom in a validated orthovoltage x-ray reference beam. Dw in a cylindrical mouse, 100 mm Petri dish, 6-well and 96-well cell culture dishes was simulated and compared to this full scatter geometry. A reference dose rate was measured using the TG-61 protocol in a cabinet irradiator. This nominal dose rate was used to irradiate TLDs in each phantom to a given dose. Doses were obtained based on TLDs calibrated in a NIST-traceable beam. Results: Compared to the full scattering conditions, the simulated dose to water in the representative geometries were found to be underestimated by 12-26%. The discrepancy was smallest with the cylindrical mouse geometry, which most closely approximates adequate lateral- and backscatter. TLDs irradiated in the mouse and petri dish phantoms using the TG-61 determined dose rate showed similarly lower values of Dw. When corrected for this discrepancy, they agreed with the predicted Dw within 5%. Conclusion: Using the TG-61 in-air protocol and given backscatter factors to determine a reference dose rate in a biological irradiator may not be appropriate given the difference in scattering conditions between irradiation and calibration. Without accounting for this, the dose rate is overestimated and is dependent on irradiation geometry.« less

  1. Measurement of Air Pollutants in the Troposphere

    ERIC Educational Resources Information Center

    Clemitshaw, Kevin C.

    2011-01-01

    This article describes the principles, applications and performances of methods to measure gas-phase air pollutants that either utilise passive or active sampling with subsequent laboratory analysis or involve automated "in situ" sampling and analysis. It focuses on air pollutants that have adverse impacts on human health (nitrogen…

  2. Equity in access to health care among asylum seekers in Germany: evidence from an exploratory population-based cross-sectional study.

    PubMed

    Bozorgmehr, Kayvan; Schneider, Christine; Joos, Stefanie

    2015-11-09

    Research on inequities in access to health care among asylum-seekers has focused on disparities between asylum-seekers and resident populations, but little attention has been paid to potential inequities in access to care within the group of asylum-seekers. We aimed to analyse the principles of horizontal equity (i.e., equal access for equal need irrespective of socioeconomic status, SES) and vertical equity (higher allocation of resources to those with higher need) among asylum-seekers in Germany. We performed a secondary exploratory analysis on cross-sectional data obtained from a population-based questionnaire survey among all asylum-seekers (aged 18 or above) registered in three administrative districts in Germany during the three-month study period (N = 1017). Data were collected on health care access (health care utilisation of four types of services and unmet medical need), health care need (approximated by sex, age and self-rated health status), and SES (highest educational attainment and subjective social status, SSS). We calculated odds ratios and 95% confidence intervals (CI) in multiple logistic regression models to analyse associations between SES indicators and access to health care under control of need. We contacted 60.4% (614) of the total asylum-seekers population, of which 25.4% (N = 156) participated in the study. Educational attainment showed no significant effect on health care access in crude models, but was positively associated with utilisation of psychotherapists and hospital admissions in adjusted models. Higher SSS was positively associated with health care utilisation of all types of services. The odds of hospitals admissions for asylum-seekers in the medium and highest SSS category were 3.18 times [1.06, 9.59] and 1.6 times [0.49, 5.23] the odds of those in the lowest SSS category. After controlling for need variables none of the SES indicators were significantly associated with measures of access to care, but a positive association remained, indicating higher utilisation of health care among asylum-seekers with higher SES. Age, sex or general health status were the only significant predictors of health care utilisation in fully adjusted models. The adjusted odds of reporting unmet medical needs among asylum-seekers with "fair/bad/very bad" health status were 2.16 times [0.84, 5.59] the odds of those with "good/very good" health status. Our findings revealed that utilisation of health services among asylum-seekers is associated with higher need (vertical equity met). Horizontal equity was met with respect to educational attainment for most outcomes, but a social gradient in health care utilisation was observed across SSS. Further confirmatory research is needed, especially on potential inequities in unmet medical need and on measurements of SES among asylum-seekers.

  3. Quantification of uncertainty in aerosol optical thickness retrieval arising from aerosol microphysical model and other sources, applied to Ozone Monitoring Instrument (OMI) measurements

    NASA Astrophysics Data System (ADS)

    Määttä, A.; Laine, M.; Tamminen, J.; Veefkind, J. P.

    2014-05-01

    Satellite instruments are nowadays successfully utilised for measuring atmospheric aerosol in many applications as well as in research. Therefore, there is a growing need for rigorous error characterisation of the measurements. Here, we introduce a methodology for quantifying the uncertainty in the retrieval of aerosol optical thickness (AOT). In particular, we concentrate on two aspects: uncertainty due to aerosol microphysical model selection and uncertainty due to imperfect forward modelling. We apply the introduced methodology for aerosol optical thickness retrieval of the Ozone Monitoring Instrument (OMI) on board NASA's Earth Observing System (EOS) Aura satellite, launched in 2004. We apply statistical methodologies that improve the uncertainty estimates of the aerosol optical thickness retrieval by propagating aerosol microphysical model selection and forward model error more realistically. For the microphysical model selection problem, we utilise Bayesian model selection and model averaging methods. Gaussian processes are utilised to characterise the smooth systematic discrepancies between the measured and modelled reflectances (i.e. residuals). The spectral correlation is composed empirically by exploring a set of residuals. The operational OMI multi-wavelength aerosol retrieval algorithm OMAERO is used for cloud-free, over-land pixels of the OMI instrument with the additional Bayesian model selection and model discrepancy techniques introduced here. The method and improved uncertainty characterisation is demonstrated by several examples with different aerosol properties: weakly absorbing aerosols, forest fires over Greece and Russia, and Sahara desert dust. The statistical methodology presented is general; it is not restricted to this particular satellite retrieval application.

  4. Radiation Measurements Performed with Active Detectors Relevant for Human Space Exploration

    PubMed Central

    Narici, Livio; Berger, Thomas; Matthiä, Daniel; Reitz, Günther

    2015-01-01

    A reliable radiation risk assessment in space is a mandatory step for the development of countermeasures and long-duration mission planning in human spaceflight. Research in radiobiology provides information about possible risks linked to radiation. In addition, for a meaningful risk evaluation, the radiation exposure has to be assessed to a sufficient level of accuracy. Consequently, both the radiation models predicting the risks and the measurements used to validate such models must have an equivalent precision. Corresponding measurements can be performed both with passive and active devices. The former is easier to handle, cheaper, lighter, and smaller but they measure neither the time dependence of the radiation environment nor some of the details useful for a comprehensive radiation risk assessment. Active detectors provide most of these details and have been extensively used in the International Space Station. To easily access such an amount of data, a single point access is becoming essential. This review presents an ongoing work on the development of a tool that allows obtaining information about all relevant measurements performed with active detectors providing reliable inputs for radiation model validation. PMID:26697408

  5. Radiation Measurements Performed with Active Detectors Relevant for Human Space Exploration.

    PubMed

    Narici, Livio; Berger, Thomas; Matthiä, Daniel; Reitz, Günther

    2015-01-01

    A reliable radiation risk assessment in space is a mandatory step for the development of countermeasures and long-duration mission planning in human spaceflight. Research in radiobiology provides information about possible risks linked to radiation. In addition, for a meaningful risk evaluation, the radiation exposure has to be assessed to a sufficient level of accuracy. Consequently, both the radiation models predicting the risks and the measurements used to validate such models must have an equivalent precision. Corresponding measurements can be performed both with passive and active devices. The former is easier to handle, cheaper, lighter, and smaller but they measure neither the time dependence of the radiation environment nor some of the details useful for a comprehensive radiation risk assessment. Active detectors provide most of these details and have been extensively used in the International Space Station. To easily access such an amount of data, a single point access is becoming essential. This review presents an ongoing work on the development of a tool that allows obtaining information about all relevant measurements performed with active detectors providing reliable inputs for radiation model validation.

  6. Recent measurements for hadrontherapy and space radiation: nuclear physics

    NASA Technical Reports Server (NTRS)

    Miller, J.

    2001-01-01

    The particles and energies commonly used for hadron therapy overlap the low end of the charge and energy range of greatest interest for space radiation applications, Z=1-26 and approximately 100-1000 MeV/nucleon. It has been known for some time that the nuclear interactions of the incident ions must be taken into account both in treatment planning and in understanding and addressing the effects of galactic cosmic ray ions on humans in space. Until relatively recently, most of the studies of nuclear fragmentation and transport in matter were driven by the interests of the nuclear physics and later, the hadron therapy communities. However, the experimental and theoretical methods and the accelerator facilities developed for use in heavy ion nuclear physics are directly applicable to radiotherapy and space radiation studies. I will briefly review relevant data taken recently at various accelerators, and discuss the implications of the measurements for radiotherapy, radiobiology and space radiation research.

  7. 78 FR 20950 - Department of Energy Facilities Covered Under the Energy Employees Occupational Illness...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-08

    ...- Health Research, University of Present [dagger]. California (Davis). Laboratory of Biomedical and Los... Radiobiology and San Francisco..... 1951-1999. Environmental Health, University of California (San Francisco........... New Brunswick..... 1948-1977. Princeton Plasma Physics Princeton......... 1951-Present. Laboratory...

  8. Curricular Guidelines for Dental Auxiliary Radiology.

    ERIC Educational Resources Information Center

    Journal of Dental Education, 1981

    1981-01-01

    AADS curricular guidelines suggest objectives for these areas of dental auxiliary radiology: physical principles of X-radiation in dentistry, related radiobiological concepts, principles of radiologic health, radiographic technique, x-ray films and intensifying screens, factors contributing to film quality, darkroom, and normal variations in…

  9. Improving sputum microscopy services for the diagnosis of tuberculosis in Peru and Bolivia.

    PubMed

    Siddiqi, K; Newell, J N; Van der Stuyft, P; Gotuzzo, E; Torrico, F; Van Deun, A; Walley, J

    2007-06-01

    Sixteen primary care health centres in Peru and Bolivia. To assess the utilisation of microscopy services in Peru and Bolivia and determine if clinical audit, a quality improvement tool, improves the utilisation of these services. We estimated the percentage of patients with suspected tuberculosis (TB) in whom sputum microscopy was effectively utilised in Peru and Bolivia over two 6-month periods before and after a clinical audit intervention that included standards setting, measuring clinical performance and feedback. Before the intervention, only 31% (95%CI 27-35) of TB suspects were assessed with sputum microscopy in Peru. In Bolivia, 30% (95%CI 25-35) underwent at least two sputum microscopy examinations. After clinical audit, the availability of sputum microscopy results improved by respectively 7% (95%CI 1-12, P < 0.05) and 23% (95%CI 15-30, P < 0.05) over 2 years in Peru and Bolivia. Despite World Health Organization recommendations that all TB suspects should undergo sputum microscopy before treatment, results are available for further assessment for only one third. This is a potentially serious obstacle to TB case detection. Clinical audit can bring some improvement. We recommend regular monitoring of effective utilisation of microscopy services and investigations to ascertain organisational and structural issues in their uptake and use.

  10. Impacts of the type of social health insurance on health service utilisation and expenditures: implications for a unified system in China.

    PubMed

    Tan, Si Ying; Wu, Xun; Yang, Wei

    2018-05-08

    While moving towards unified social health insurance (SHI) is often a politically popular policy reform in countries where rapid expansion in health insurance coverage has given rise to the segmentation of SHI systems as different SHI schemes were rolled out to serve different populations, the potential impacts of reform on service utilisation and health costs have not been systematically studied. Using data from the Chinese Health and Retirement Longitudinal Study (CHARLS), we compared the mean costs incurred for both inpatient and outpatient care under different health insurance schemes, and the impact of different SHI schemes on treatment utilisation and health care costs using a two-part model. Our results show that Urban Employee Medical Insurance, which offers the most generous benefits, incurs the highest total costs prior to reimbursement when compared to other SHI schemes. Our analysis also shows that utilisation of SHI did not show significant reduction in out-of-pocket payments for outpatients. We argue that, unless effective measures are introduced to deal with perverse provider payment incentives, the move towards a unified system with more generous benefits may usher in a new wave of cost escalation for health care systems in China.

  11. Utilisation of health services and the poor: deconstructing wealth-based differences in facility-based delivery in the Philippines.

    PubMed

    Hodge, Andrew; Firth, Sonja; Bermejo, Raoul; Zeck, Willibald; Jimenez-Soto, Eliana

    2016-07-06

    Despite achieving some success, wealth-related disparities in the utilisation of maternal and child health services persist in the Philippines. The aim of this study is to decompose the principal factors driving the wealth-based utilisation gap. Using national representative data from the 2013 Philippines Demographic and Health Survey, we examine the extent overall differences in the utilisation of maternal health services can be explained by observable factors. We apply nonlinear Blinder-Oaxaca-type decomposition methods to quantify the effect of differences in measurable characteristics on the wealth-based coverage gap in facility-based delivery. The mean coverage of facility-based deliveries was respectively 41.1 % and 74.6 % for poor and non-poor households. Between 67 and 69 % of the wealth-based coverage gap was explained by differences in observed characteristics. After controlling for factors characterising the socioeconomic status of the household (i.e. the mothers' and her partners' education and occupation), the birth order of the child was the major factor contributing to the disparity. Mothers' religion and the subjective distance to the health facility were also noteworthy. This study has found moderate wealth-based disparities in the utilisation of institutional delivery in the Philippines. The results confirm the importance of recent efforts made by the Philippine government to implement equitable, pro-poor focused health programs in the most deprived geographic areas of the country. The importance of addressing the social determinants of health, particularly education, as well as developing and implementing effective strategies to encourage institutional delivery for higher order births, should be prioritised.

  12. The effect of overbooking on idle dental chair capacity in the Pretoria region of the Gauteng Oral Health Services.

    PubMed

    Holtshousen, W S J; Coetzee, E

    2012-09-01

    An analysis of annual reports revealed that on average 20% of patient appointments with oral hygienists in the Department of Health in the Pretoria region were not utilised due to patient noncompliance (i.e. broken appointments). Many solutions have been considered to address the high rate of noncompliance and the resulting idle chair capacity. One solution selected to overcome some of the negative consequences of broken appointments was deliberate overbooking. The aim of our study was to determine the effect of overbooking on idle dental chair capacity by measuring the utilisation rate over a three month period (July to September) after 25% overbooking was introduced in the Pretoria region. A statistical analysis was conducted on our results to determine an overbooking rate that would ensure full utilisation of the available dental chair capacity. The available time units over the three month study period amounted to 1365, allocated to 1427 patients resulting in an overal overbooking rate of 4.54%. The overall utilisation rate was found to be 79.2%. The calculated regression line estimated that there would be full utilisation of dental chair capacity at an overbooking rate of 26.7%. Overbooking at the levels applied in this study had a minimal overall effect on idle dental chair capacity. Our results confirm the need for careful planning and management in addressing noncompliance. In a manner similar to the clinical situation, organisational development requires a correct diagnosis in order that an appropriate and effective intervention may be designed.

  13. Using Scratch: An Integrated Problem-Solving Approach to Mathematical Thinking

    ERIC Educational Resources Information Center

    Calder, Nigel

    2010-01-01

    "Scratch" is a media-rich digital environment that utilises a building block command structure to manipulate graphic, audio, and video aspects. It incorporates elements of Logo including "tinkerability" in the programming process. In "Scratch" students use geometric and measurement concepts such as coordinates, angle, and length measurements. It…

  14. University Performance Evaluations: What Are We Really Measuring?

    ERIC Educational Resources Information Center

    Bedggood, Rowan E.; Donovan, Jerome D.

    2012-01-01

    Surveying students to garner feedback on teaching and subject quality is a common occurrence in many universities globally. Despite the criticisms surrounding whether measures associated with these surveys are indeed valid, university managers continue to utilise them in key decision making. These surveys mirror business practices where measuring…

  15. Apelin targets gut contraction to control glucose metabolism via the brain.

    PubMed

    Fournel, Audren; Drougard, Anne; Duparc, Thibaut; Marlin, Alysson; Brierley, Stuart M; Castro, Joel; Le-Gonidec, Sophie; Masri, Bernard; Colom, André; Lucas, Alexandre; Rousset, Perrine; Cenac, Nicolas; Vergnolle, Nathalie; Valet, Philippe; Cani, Patrice D; Knauf, Claude

    2017-02-01

    The gut-brain axis is considered as a major regulatory checkpoint in the control of glucose homeostasis. The detection of nutrients and/or hormones in the duodenum informs the hypothalamus of the host's nutritional state. This process may occur via hypothalamic neurons modulating central release of nitric oxide (NO), which in turn controls glucose entry into tissues. The enteric nervous system (ENS) modulates intestinal contractions in response to various stimuli, but the importance of this interaction in the control of glucose homeostasis via the brain is unknown. We studied whether apelin, a bioactive peptide present in the gut, regulates ENS-evoked contractions, thereby identifying a new physiological partner in the control of glucose utilisation via the hypothalamus. We measured the effect of apelin on electrical and mechanical duodenal responses via telemetry probes and isotonic sensors in normal and obese/diabetic mice. Changes in hypothalamic NO release, in response to duodenal contraction modulated by apelin, were evaluated in real time with specific amperometric probes. Glucose utilisation in tissues was measured with orally administrated radiolabeled glucose. In normal and obese/diabetic mice, glucose utilisation is improved by the decrease of ENS/contraction activities in response to apelin, which generates an increase in hypothalamic NO release. As a consequence, glucose entry is significantly increased in the muscle. Here, we identify a novel mode of communication between the intestine and the hypothalamus that controls glucose utilisation. Moreover, our data identified oral apelin administration as a novel potential target to treat metabolic disorders. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  16. Pig producer perspectives on the use of meat inspection as an animal health and welfare diagnostic tool in the Republic of Ireland and Northern Ireland.

    PubMed

    Devitt, Catherine; Boyle, Laura; Teixeira, D L; O'Connell, N E; Hawe, M; Hanlon, Alison

    2015-01-01

    Currently, there is growing interest in developing ante and post mortem meat inspection (MI) to incorporate measures of pig health and welfare for use as a diagnostic tool on pig farms. However, the success of the development of the MI process requires stakeholder engagement with the process. Knowledge gaps and issues of trust can undermine the effective exchange and utilisation of information across the supply chain. A social science research methodology was employed to establish stakeholder perspectives towards the development of MI to include measures of pig health and welfare. In this paper the findings of semi-structured telephone interviews with 18 pig producers from the Republic of Ireland and Northern Ireland are presented. Producers recognised the benefit of the utilisation of MI data as a health and welfare diagnostic tool. This acknowledgment, however, was undermined for some by dissatisfaction with the current system of MI information feedback, by trust and fairness concerns, and by concerns regarding the extent to which data would be used in the producers' interests. Tolerance of certain animal welfare issues may also have a negative impact on how producers viewed the potential of MI data. The private veterinary practitioner was viewed as playing a vital role in assisting them with the interpretation of MI data for herd health planning. The development of positive relationships based on trust, commitment and satisfaction across the supply chain may help build a positive environment for the effective utilisation of MI data in improving pig health and welfare. The utilisation of MI as a diagnostic tool would benefit from the development of a communication strategy aimed at building positive relationships between stakeholders in the pig industry.

  17. Chasing Ghosts in Space Radiobiology Research: The Lost Focus on Non-Targeted Effects

    NASA Astrophysics Data System (ADS)

    Cucinotta, Francis; Saganti, Premkumar; Cacao, Eliedonna

    2016-07-01

    The doses and dose-rates of astronaut exposures to galactic cosmic rays (GCR) are accurately known, and lead to particle hits per cell nucleus from high charge and energy (HZE) particles of much less than one hit per cell per week. A large number of experiments have shown that additivity of biological effects is a valid assumption for space radiation exposures, while experiments at higher doses and dose-rates than occur in space continue to be a focus of the majority of space radiobiology research. Furthermore HZE particle exposures with mono-energetic particles manifest themselves as a mixed-radiation field due to the contributions of delta-rays and the random impact parameter of a particles track core to DNA and non-DNA targets in cells and tissues. The mixed-field manifestation of mono-energetic HZE particle exposures is well known from theoretical studies of microdosimetry and track structure. Additional mixed-field effects occur for single species experiments due to nuclear fragmentation in particle accelerator beam-lines and biological samples along with energy straggling. In contrast to these well known aspects of space radiobiology there are many open questions on the contribution of non-targeted effects to low dose and dose-rate exposures. Non-targeted effects (NTEs) include bystander effects and genomic instability, and have been shown to be the most important outstanding question for reducing uncertainties in space radiation cancer risk assessment. The dose-rate and radiation quality dependence of NTE's has not been established, while there is an over-arching need to develop 21st century experimental models of human cancer risk. We review possible mechanisms of NTE's and how new experiments to address these issues could be designed.

  18. SU-E-J-172: Bio-Physical Effects of Patients Set-Up Errors According to Whole Breast Irradiation Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, S; Suh, T; Park, S

    2015-06-15

    Purpose: The dose-related effects of patient setup errors on biophysical indices were evaluated for conventional wedge (CW) and field-in-field (FIF) whole breast irradiation techniques. Methods: The treatment plans for 10 patients receiving whole left breast irradiation were retrospectively selected. Radiobiological and physical effects caused by dose variations were evaluated by shifting the isocenters and gantry angles of the treatment plans. Dose-volume histograms of the planning target volume (PTV), heart, and lungs were generated, and conformity index (CI), homogeneity index (HI), tumor control probability (TCP), and normal tissue complication probability (NTCP) were determined. Results: For “isocenter shift plan” with posterior direction,more » the D95 of the PTV decreased by approximately 15% and the TCP of the PTV decreased by approximately 50% for the FIF technique and by 40% for the CW; however, the NTCPs of the lungs and heart increased by about 13% and 1%, respectively, for both techniques. Increasing the gantry angle decreased the TCPs of the PTV by 24.4% (CW) and by 34% (FIF). The NTCPs for the two techniques differed by only 3%. In case of CW, the CIs and HIs were much higher than that of the FIF in all cases. It had a significant difference between two techniques (p<0.01). According to our results, however, the FIF had more sensitive response by set up errors rather than CW in bio-physical aspects. Conclusions: The radiobiological-based analysis can detect significant dosimetric errors then, can provide a practical patient quality assurance method to guide the radiobiological and physical effects.« less

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Granzotto, Adeline; Benadjaoud, Mohamed Amine; Vogin, Guillaume

    Purpose: Whereas post–radiation therapy overreactions (OR) represent a clinical and societal issue, there is still no consensual radiobiological endpoint to predict clinical radiosensitivity. Since 2003, skin biopsy specimens have been collected from patients treated by radiation therapy against different tumor localizations and showing a wide range of OR. Here, we aimed to establish quantitative links between radiobiological factors and OR severity grades that would be relevant to radioresistant and genetic hyperradiosensitive cases. Methods and Materials: Immunofluorescence experiments were performed on a collection of skin fibroblasts from 12 radioresistant, 5 hyperradiosensitive, and 100 OR patients irradiated at 2 Gy. The numbers ofmore » micronuclei, γH2AX, and pATM foci that reflect different steps of DNA double-strand breaks (DSB) recognition and repair were assessed from 10 minutes to 24 hours after irradiation and plotted against the severity grades established by the Common Terminology Criteria for Adverse Events and the Radiation Therapy Oncology Group. Results: OR patients did not necessarily show a gross DSB repair defect but a systematic delay in the nucleoshuttling of the ATM protein required for complete DSB recognition. Among the radiobiological factors, the maximal number of pATM foci provided the best discrimination among OR patients and a significant correlation with each OR severity grade, independently of tumor localization and of the early or late nature of reactions. Conclusions: Our results are consistent with a general classification of human radiosensitivity based on 3 groups: radioresistance (group I); moderate radiosensitivity caused by delay of nucleoshuttling of ATM, which includes OR patients (group II); and hyperradiosensitivity caused by a gross DSB repair defect, which includes fatal cases (group III).« less

  20. Dosimetric and microdosimetric analyses for blood exposed to reactor-derived thermal neutrons.

    PubMed

    Ali, F; Atanackovic, J; Boyer, C; Festarini, A; Kildea, J; Paterson, L C; Rogge, R; Stuart, M; Richardson, R B

    2018-06-06

    Thermal neutrons are found in reactor, radiotherapy, aircraft, and space environments. The purpose of this study was to characterise the dosimetry and microdosimetry of thermal neutron exposures, using three simulation codes, as a precursor to quantitative radiobiological studies using blood samples. An irradiation line was designed employing a pyrolytic graphite crystal or-alternatively-a super mirror to expose blood samples to thermal neutrons from the National Research Universal reactor to determine radiobiological parameters. The crystal was used when assessing the relative biological effectiveness for dicentric chromosome aberrations, and other biomarkers, in lymphocytes over a low absorbed dose range of 1.2-14 mGy. Higher exposures using a super mirror will allow the additional quantification of mitochondrial responses. The physical size of the thermal neutron fields and their respective wavelength distribution was determined using the McStas Monte Carlo code. Spinning the blood samples produced a spatially uniform absorbed dose as determined from Monte Carlo N-Particle version 6 simulations. The major part (71%) of the total absorbed dose to blood was determined to be from the 14 N(n,p) 14 C reaction and the remainder from the 1 H(n,γ) 2 H reaction. Previous radiobiological experiments at Canadian Nuclear Laboratories involving thermal neutron irradiation of blood yielded a relative biological effectiveness of 26 ± 7. Using the Particle and Heavy Ion Transport Code System, a similar value of ∼19 for the quality factor of thermal neutrons initiating the 14 N(n,p) 14 C reaction in soft tissue was determined by microdosimetric simulations. This calculated quality factor is of similar high value to the experimentally-derived relative biological effectiveness, and indicates the potential of thermal neutrons to induce deleterious health effects in superficial organs such as cataracts of the eye lens.

  1. Influence of Prostatic Edema on {sup 131}CS Permanent Prostate Seed Implants: A Dosimetric and Radiobiological Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kehwar, Than S., E-mail: kehwarts@upmc.ed; Jones, Heather A.; Huq, M. Saiful

    2011-06-01

    Purpose: To study the influence of prostatic edema on postimplant physical and radiobiological parameters using {sup 131}Cs permanent prostate seed implants. Methods and Materials: Thirty-one patients with early prostate cancer who underwent {sup 131}Cs permanent seed implantation were evaluated. Dose-volume histograms were generated for each set of prostate volumes obtained at preimplantation and postimplantion days 0, 14, and 28 to compute quality indices (QIs) and fractional doses at level x (FD{sub x}). A set of equations for QI, FD{sub x}, and biologically effective doses at dose level D{sub x} (BED{sub x}) were defined to account for edema changes with timemore » after implant. Results: There were statistically significant differences found between QIs of pre- and postimplant plans at day 0, except for the overdose index (ODI). QIs correlated with postimplant time, and FD{sub x} was found to increase with increasing postimplant time. With the effect of edema, BED at different dose levels showed less improvement due to the short half-life of {sup 131}Cs, which delivers about 85% of the prescribed dose before the prostate reaches its original volume due to dissipation of edema. Conclusions: Results of the study show that QIs, FD{sub x}, and BEDs at the level of D{sub x} changed from preneedle plans to postimplant plans and have statistically significant differences (p < 0.05), except for the ODI (p = 0.106), which suggests that at the time of {sup 131}C seed implantation, the effect of edema must be accounted for when defining the seed positions, to avoid the possibility of poor dosimetric and radiobiologic results for {sup 131}Cs seed implants.« less

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zaorsky, Nicholas G.; Malatesta, Theresa M.; Den, Robert B.

    Purpose: Few medical students are given proper clinical training in oncology, much less radiation oncology. We attempted to assess the value of adding a radiation oncology clinical rotation to the medical school curriculum. Methods and Materials: In July 2010, Jefferson Medical College began to offer a 3-week radiation oncology rotation as an elective course for third-year medical students during the core surgical clerkship. During 2010 to 2012, 52 medical students chose to enroll in this rotation. The rotation included outpatient clinics, inpatient consults, didactic sessions, and case-based presentations by the students. Tests of students' knowledge of radiation oncology were administeredmore » anonymously before and after the rotation to evaluate the educational effectiveness of the rotation. Students and radiation oncology faculty were given surveys to assess feedback about the rotation. Results: The students' prerotation test scores had an average of 64% (95% confidence interval [CI], 61-66%). The postrotation test scores improved to an average of 82% (95% CI, 80-83%; 18% absolute improvement). In examination question analysis, scores improved in clinical oncology from 63% to 79%, in radiobiology from 70% to 77%, and in medical physics from 62% to 88%. Improvements in all sections but radiobiology were statistically significant. Students rated the usefulness of the rotation as 8.1 (scale 1-9; 95% CI, 7.3-9.0), their understanding of radiation oncology as a result of the rotation as 8.8 (95% CI, 8.5-9.1), and their recommendation of the rotation to a classmate as 8.2 (95% CI, 7.6-9.0). Conclusions: Integrating a radiation oncology clinical rotation into the medical school curriculum improves student knowledge of radiation oncology, including aspects of clinical oncology, radiobiology, and medical physics. The rotation is appreciated by both students and faculty.« less

  3. Transnational science and collaborative networks. The case of Genetics and Radiobiology in Mexico, 1950-1970.

    PubMed

    Barahona, Ana

    2015-01-01

    The transnational approach of the science and technology studies (S&TS) abandons the nation as a unit of analysis in order to understand the development of science history. It also abandons Euro-US-centred narratives in order to explain the role of international collaborative networks and the circulation of knowledge, people, artefacts and scientific practices. It is precisely under this perspective that the development of genetics and radiobiology in Mexico shall be analyzed, together with the pioneering work of the Mexican physician-turned-geneticist Alfonso León de Garay who spent two years in the Galton Laboratory in London under the supervision of Lionel Penrose. Upon his return de Garay funded the Genetics and Radiobiology Program of the National Commission of Nuclear Energy based on local needs and the aim of working beyond geographical limitations to thus facilitate the circulation of knowledge, practices and people. The three main lines of research conducted in the years after its foundation that were in line with international projects while responding to the national context were, first, cytogenetic studies of certain abnormalities, and the cytogenetics and anthropological studies of the Olympic Games held in Mexico in 1968; second, the study of the effects of radiation on hereditary material; and third, the study of population genetics in Drosophila and in Mexican indigenous groups. The program played a key role in reshaping the scientific careers of Mexican geneticists, and in transferring locally sourced research into broader networks. This case shows the importance of international collaborative networks and circulation in the constitution of national scientific elites, and also shows the national and transnational concerns that shaped local practices.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Is Non-invasive Image-Guided Breast Brachytherapy Good? – Jess Hiatt, MS Non-invasive Image-Guided Breast Brachytherapy (NIBB) is an emerging therapy for breast boost treatments as well as Accelerated Partial Breast Irradiation (APBI) using HDR surface breast brachytherapy. NIBB allows for smaller treatment volumes while maintaining optimal target coverage. Considering the real-time image-guidance and immobilization provided by the NIBB modality, minimal margins around the target tissue are necessary. Accelerated Partial Breast Irradiation in brachytherapy: is shorter better? - Dorin Todor, PhD VCU A review of balloon and strut devices will be provided together with the origins of APBI: the interstitial multi-catheter implant.more » A dosimetric and radiobiological perspective will help point out the evolution in breast brachytherapy, both in terms of devices and the protocols/clinical trials under which these devices are used. Improvements in imaging, delivery modalities and convenience are among the factors driving the ultrashort fractionation schedules but our understanding of both local control and toxicities associated with various treatments is lagging. A comparison between various schedules, from a radiobiological perspective, will be given together with a critical analysis of the issues. to review and understand the evolution and development of APBI using brachytherapy methods to understand the basis and limitations of radio-biological ‘equivalence’ between fractionation schedules to review commonly used and proposed fractionation schedules Intra-operative breast brachytherapy: Is one stop shopping best?- Bruce Libby, PhD. University of Virginia A review of intraoperative breast brachytherapy will be presented, including the Targit-A and other trials that have used electronic brachytherapy. More modern approaches, in which the lumpectomy procedure is integrated into an APBI workflow, will also be discussed. Learning Objectives: To review past and current clinical trials for IORT To discuss lumpectomy-scan-plan-treat workflow for IORT.« less

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, J. Martin, E-mail: mbrown@stanford.edu; Carlson, David J.; Brenner, David J.

    Stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT), also known as stereotactic ablative radiation therapy (SABR), are rapidly becoming accepted practice for the radiation therapy of certain tumors. Typically, SRS and SBRT involve the delivery of 1 or a few large-dose fractions of 8 to 30 Gy per fraction: a major paradigm shift from radiation therapy practice over the past 90 years, when, with relatively large amounts of normal tissues receiving high doses, the goal was to maximize tumor response for an acceptable level of normal tissue injury. The development of SRS and SBRT have come about because ofmore » technologic advances in image guidance and treatment delivery techniques that enable the delivery of large doses to tumors with reduced margins and high gradients outside the target, thereby minimizing doses to surrounding normal tissues. Because the results obtained with SRS and SBRT have been impressive, they have raised the question whether classic radiobiological modeling, and the linear-quadratic (LQ) model, are appropriate for large doses per fraction. In addition to objections to the LQ model, the possibility of additional biological effects resulting from endothelial cell damage, enhanced tumor immunity, or both have been raised to account for the success of SRS and SBRT. In this review, we conclude that the available preclinical and clinical data do not support a need to change the LQ model or to invoke phenomena over and above the classic 5 Rs of radiobiology and radiation therapy, with the likely exception that for some tumors high doses of irradiation may produce enhanced antitumor immunity. Thus, we suggest that for most tumors, the standard radiobiology concepts of the 5 Rs are sufficient to explain the clinical data, and the excellent results obtained from clinical studies are the result of the much larger biologically effective doses that are delivered with SRS and SBRT.« less

  6. [Frequency of use of school cafeterias in middle and high schools in 3 French districts].

    PubMed

    Michaud, C; Feur, E; Gerbouin-Rérolle, P; Leynaud-Rouaud, C; Chateil, S; Gourdon, M

    2000-09-01

    Reports from the French Ministry of Education warn of a decrease in the use of school food services, especially in sensitive urban areas. They also suggest that this decline has led to cases of malnutrition. This article describes the characteristics of the current supply of school meals and measures the evolution of demand observed between 1992 and 1996 in relation to the economic situation of students' families. The study was carried out in 3 departments in France: Doubs, Herault, and Val de Marne. The administrators of all public and private middle and high schools in the 3 departments received a questionnaire asking them to describe the services offered in their cafeterias and to provide the corresponding statistical and accounting data. External food services near the schools were also taken into account. Seventy-nine percent of schools responded to the survey. Concerning the services offered, 91% of schools have their own cafeterias, of which 81% are managed by the schools. Concerning the evolution of utilisation, a significant decrease in the number of meals served in seen in middle schools. On the other hand, high schools have observed stable utilisation. The positive changes in utilisation are linked, in middle schools, to characteristics of the schools' internal food services (self-service, choice of main courses, modulation of seats). In high schools, positive changes in the utilisation of school services are linked to the lack of external food services near the schools. As middle schools and high schools control the logistics and management of food services offered to students, they are potentially in a position to influence a policy on this issue. The evolution in utilisation is very different among departments and between middle and high schools. While economic precariousness has a negative structural effect on utilisation, it doesn't seem to be a major factor in the evolution of the decrease observed over the past few years.

  7. Utilisation of antihyperglycaemic drugs in ten European countries: different developments and different levels.

    PubMed

    Melander, A; Folino-Gallo, P; Walley, T; Schwabe, U; Groop, P-H; Klaukka, T; Vallano, A; Laporte, J-R; Gallego, M R; Schiappa, M; Røder, M; Kampmann, J P; de Swaef, A; Aberg, M; Månsson, N-O; Lindblad, U

    2006-09-01

    The aim of this study was to compare developments in the utilisation of antihyperglycaemic drugs (AHGDs) in ten European countries. Data on the yearly utilisation of insulin and oral AHGDs were collected from public registers in Denmark, Finland, Norway, Sweden, Belgium, England, Germany, Italy, Portugal and Spain, and were expressed as defined daily doses per 1,000 inhabitants per day. Total AGHD utilisation increased everywhere, but at different rates and levels. Insulin utilisation doubled in England and Germany, but hardly changed in Belgium, Portugal or Italy. Sulfonylurea utilisation doubled in Spain, England and Denmark but was reduced in Germany and Sweden. Metformin utilisation increased greatly everywhere. There were two- to three-fold differences in AHGD utilisation even between neighbouring countries. In Finland, there were more users of both insulin (+120%) and oral AHGDs (+80%) than in Denmark, and the daily oral AHGD doses were higher. In Denmark and Sweden, AHGD utilisation was equal in subjects aged <45 years, but in those >or=45 years of age, both insulin and oral AHGD utilisation were twice as high in Sweden. The ubiquitous increase in AHGD utilisation, particularly metformin, seems logical, considering the increasing prevalence of type 2 diabetes and the results of the UK Prospective Diabetes Study. However, the large differences even between neighbouring countries are more difficult to explain, and suggest different habits and attitudes in terms of screening and management of type 2 diabetes.

  8. Web service discovery among large service pools utilising semantic similarity and clustering

    NASA Astrophysics Data System (ADS)

    Chen, Fuzan; Li, Minqiang; Wu, Harris; Xie, Lingli

    2017-03-01

    With the rapid development of electronic business, Web services have attracted much attention in recent years. Enterprises can combine individual Web services to provide new value-added services. An emerging challenge is the timely discovery of close matches to service requests among large service pools. In this study, we first define a new semantic similarity measure combining functional similarity and process similarity. We then present a service discovery mechanism that utilises the new semantic similarity measure for service matching. All the published Web services are pre-grouped into functional clusters prior to the matching process. For a user's service request, the discovery mechanism first identifies matching services clusters and then identifies the best matching Web services within these matching clusters. Experimental results show that the proposed semantic discovery mechanism performs better than a conventional lexical similarity-based mechanism.

  9. Determination of the predictive factors of long-lasting insecticide-treated net ownership and utilisation in the Bamenda Health District of Cameroon.

    PubMed

    Fokam, Eric B; Kindzeka, Germaine F; Ngimuh, Leonard; Dzi, Kevin T J; Wanji, Samuel

    2017-03-16

    Malaria is a serious health concern in Africa. In Cameroon, an endemic country where malaria remains a major public health problem, several control measures have been put in place among which the use of insecticide-treated bednets (LLINs/ITNs) is considered one of the core vector control strategies. However, the greatest challenges include ownership and utilisation by individuals and households. Factors such as age, marital status, gender, education and occupation of the household head, household size, knowledge of bednets, socioeconomic status, and environmental factors have been suggested to have an impact on bednet ownership and utilisation in different settings. The present study sought to determine bednet ownership and utilisation rates and to assess the impact of predictive factors on bednet ownership and use in the Bamenda Health District (BHD) of Cameroon. A cross-sectional study involving 384 households was conducted in six health areas in the BHD. A structured and semi-structured questionnaire was used to collect data on demographic and household characteristics as well as information on their bednet ownership and utilisation. Descriptive statistics, bivariate and multivariate logistic regression analysis were performed. Frequency of bednet ownership was relatively high (63.5%) with LLINs being most abundant (91.9%); the majority of households (87.7%) obtained their bednets during the 2011 free distribution campaign. Utilisation was relatively high (69.3%), with negligence (29.3%) and heat discomfort (26.7%) accounting most for non-usage of bednets. Children less than 5 years (63%) and pregnant women (60%) most often used these nets. Households headed by a married couple, those with older household heads, household with smaller size (5-12 persons), and knowledge of bednets (good knowledge) had positive impacts on bednet ownership (p < 0.05). The gender of the household head (males), their educational level, environmental conditions (presence of suitable mosquito breeding sites), bednet number in households (greater number of bednets) and the prioritised groups (children < 5 and pregnant women) had positive impacts on bednet utilisation in households (p < 0.05). There was a negative association between bednet ownership and utilisation by households as bednet ownership was high and utilisation of these nets was low. Marital status and age of household head, household size, and knowledge of bednets had impacts on bednet ownership while gender and educational level of the household head, environmental suitability, the number of bednets and the two prioritised groups had an impact on bednet usage. These factors may be relevant for policy makers and in decision making for the intensification of campaign strategies to ensure more effective subsequent distribution campaigns in the BHD and beyond.

  10. Household training vs. mass campaigns: a better method of health communication for preventing malaria.

    PubMed

    Chourasia, Mehul Kumar; Abraham, Vinod J; John, Jacob

    2014-10-01

    Malaria is endemic in several states of India with high tribal population. Effective use of long-lasting insecticide treated bed nets (LLITNs) can reduce the burden of malaria in these settings. This study assessed the knowledge and behaviour regarding malaria in a tribal population and compared two health education strategies for enhancing effective utilisation of bed nets. A community-based intervention study was carried out among 218 households in two villages. One community received household level training on effective utilisation of LLITNs while the others received training in a mass campaign and outcomes were measured after 2 months. The study showed that the proportion utilising LLITNs was significantly higher among those receiving household level training as compared to those who received the mass campaign. Household level training appears to be a more effective form of health education for improving knowledge and promoting use of LLITNs in these isolated community groups. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  11. Controlling chromium slag pollution utilising scavengers: a case of Shandong Province, China.

    PubMed

    Liu, Changhao; Côté, Raymond P

    2015-04-01

    The problem of chromium slag pollution is a great challenge for China. It is now an urgent task for China to take effective measures to eliminate chromium slag pollution. This article examines the case of the treatment of chromium slag in Shandong Province and explores how chromium slag pollution can be eliminated in Shandong Province. It shows that the chromium slag stockpiled by the chemical plants was successfully utilised by local steel companies, who act as 'scavenger companies'. The driving mechanism, seeking a potential 'scavenger company' within the local region and the role of the local government on the case of Shandong Province are discussed. This article concludes that local steel companies can be utilised to effectively and efficiently treat the chromium slag while benefiting the steel companies. The local governments need to play multiple roles in solving the problem of chromium slag pollution. Seeking and identifying 'scavenger companies' within a region could be an important approach to reducing pollution within the region. © The Author(s) 2015.

  12. Early primary care physician contact and health service utilisation in a large sample of recently released ex-prisoners in Australia: prospective cohort study

    PubMed Central

    Arnold-Reed, Diane; Preen, David; Bulsara, Max; Lennox, Nick; Kinner, Stuart A

    2015-01-01

    Objective To describe the association between ex-prisoner primary care physician contact within 1 month of prison release and health service utilisation in the 6 months following release. Design A cohort from the Passports study with a mean follow-up of 219 (±44) days postrelease. Associations were assessed using a multivariate Andersen-Gill model, controlling for a range of other factors. Setting Face-to-face, baseline interviews were conducted in a sample of prisoners within 6 weeks of expected release from seven prisons in Queensland, Australia, from 2008 to 2010, with telephone follow-up interviews 1, 3 and 6 months postrelease. Participants From an original population-based sample of 1325 sentenced adult (≥18 years) prisoners, 478 participants were excluded due to not being released from prison during follow-up (n=7, 0.5%), loss to follow-up (n=257, 19.4%), or lacking exposure data (n=214, 16.2%). A total of 847 (63.9%) participants were included in the analyses. Exposure Primary care physician contact within 1 month of follow-up as a dichotomous measure. Main outcome measures Adjusted time-to-event hazard rates for hospital, mental health, alcohol and other drug and subsequent primary care physician service utilisations assessed as multiple failure time-interval data. Results Primary care physician contact prevalence within 1 month of follow-up was 46.5%. One-month primary care physician contact was positively associated with hospital (adjusted HR (AHR)=2.07; 95% CI 1.39 to 3.09), mental health (AHR=1.65; 95% CI 1.24 to 2.19), alcohol and other drug (AHR=1.48; 95% CI 1.15 to 1.90) and subsequent primary care physician service utilisation (AHR=1.47; 95% CI 1.26 to 1.72) over 6 months of follow-up. Conclusions Engagement with primary care physician services soon after prison release increases health service utilisation during the critical community transition period for ex-prisoners. Trial registration number Australian New Zealand Clinical Trials Registry (ACTRN12608000232336). PMID:26068513

  13. Comparison of different fractionation schedules toward a single fraction in high-dose-rate brachytherapy as monotherapy for low-risk prostate cancer using 3-dimensional radiobiological models.

    PubMed

    Mavroidis, Panayiotis; Milickovic, Natasa; Cruz, Wilbert F; Tselis, Nikolaos; Karabis, Andreas; Stathakis, Sotirios; Papanikolaou, Nikos; Zamboglou, Nikolaos; Baltas, Dimos

    2014-01-01

    The aim of the present study was the investigation of different fractionation schemes to estimate their clinical impact. For this purpose, widely applied radiobiological models and dosimetric measures were used to associate their results with clinical findings. The dose distributions of 12 clinical high-dose-rate brachytherapy implants for prostate were evaluated in relation to different fractionation schemes. The fractionation schemes compared were: (1) 1 fraction of 20 Gy; (2) 2 fractions of 14 Gy; (3) 3 fractions of 11 Gy; and (4) 4 fractions of 9.5 Gy. The clinical effectiveness of the different fractionation schemes was estimated through the complication-free tumor control probability (P+), the biologically effective uniform dose, and the generalized equivalent uniform dose index. For the different fractionation schemes, the tumor control probabilities were 98.5% in 1×20 Gy, 98.6% in 2×14 Gy, 97.5% in 3×11 Gy, and 97.8% in 4×9.5 Gy. The corresponding P+ values were 88.8% in 1×20 Gy, 83.9% in 2×14 Gy, 86.0% in 3×11 Gy, and 82.3% in 4×9.5 Gy. With use of the fractionation scheme 4×9.5 Gy as reference, the isoeffective schemes regarding tumor control for 1, 2, and 3 fractions were 1×19.68 Gy, 2×13.75 Gy, and 3×11.05 Gy. The optimum fractionation schemes for 1, 2, 3, and 4 fractions were 1×19.16 Gy with a P+ of 91.8%, 2×13.2 Gy with a P+ of 89.6%, 3×10.6 Gy with a P+ of 88.4%, and 4×9.02 Gy with a P+ of 86.9%. Among the fractionation schemes 1×20 Gy, 2×14 Gy, 3×11 Gy, and 4×9.5 Gy, the first scheme was more effective in terms of P+. After performance of a radiobiological optimization, it was shown that a single fraction of 19.2 to 19.7 Gy (average 19.5 Gy) should produce at least the same benefit as that given by the 4×9.5 Gy scheme, and it should reduce the expected total complication probability by approximately 40% to 55%. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Comparison of Different Fractionation Schedules Toward a Single Fraction in High-Dose-Rate Brachytherapy as Monotherapy for Low-Risk Prostate Cancer Using 3-Dimensional Radiobiological Models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mavroidis, Panayiotis, E-mail: mavroidis@uthscsa.edu; Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, Stockholm; Milickovic, Natasa

    2014-01-01

    Purpose: The aim of the present study was the investigation of different fractionation schemes to estimate their clinical impact. For this purpose, widely applied radiobiological models and dosimetric measures were used to associate their results with clinical findings. Methods and Materials: The dose distributions of 12 clinical high-dose-rate brachytherapy implants for prostate were evaluated in relation to different fractionation schemes. The fractionation schemes compared were: (1) 1 fraction of 20 Gy; (2) 2 fractions of 14 Gy; (3) 3 fractions of 11 Gy; and (4) 4 fractions of 9.5 Gy. The clinical effectiveness of the different fractionation schemes was estimatedmore » through the complication-free tumor control probability (P{sub +}), the biologically effective uniform dose, and the generalized equivalent uniform dose index. Results: For the different fractionation schemes, the tumor control probabilities were 98.5% in 1 × 20 Gy, 98.6% in 2 × 14 Gy, 97.5% in 3 × 11 Gy, and 97.8% in 4 × 9.5 Gy. The corresponding P{sub +} values were 88.8% in 1 × 20 Gy, 83.9% in 2 × 14 Gy, 86.0% in 3 × 11 Gy, and 82.3% in 4 × 9.5 Gy. With use of the fractionation scheme 4 × 9.5 Gy as reference, the isoeffective schemes regarding tumor control for 1, 2, and 3 fractions were 1 × 19.68 Gy, 2 × 13.75 Gy, and 3 × 11.05 Gy. The optimum fractionation schemes for 1, 2, 3, and 4 fractions were 1 × 19.16 Gy with a P{sub +} of 91.8%, 2 × 13.2 Gy with a P{sub +} of 89.6%, 3 × 10.6 Gy with a P{sub +} of 88.4%, and 4 × 9.02 Gy with a P{sub +} of 86.9%. Conclusions: Among the fractionation schemes 1 × 20 Gy, 2 × 14 Gy, 3 × 11 Gy, and 4 × 9.5 Gy, the first scheme was more effective in terms of P{sub +}. After performance of a radiobiological optimization, it was shown that a single fraction of 19.2 to 19.7 Gy (average 19.5 Gy) should produce at least the same benefit as that given by the 4 × 9.5 Gy scheme, and it should reduce the expected total complication probability by approximately 40% to 55%.« less

  15. Space radiation studies at the White Sands Missile Range Fast Burst Reactor

    NASA Technical Reports Server (NTRS)

    Delapaz, A.

    1972-01-01

    The operation of the White Sands Missile Range Fast Burst Reactor is discussed. Space radiation studies in radiobiology, dosimetry, and transient radiation effects on electronic systems and components are described. Proposed modifications to increase the capability of the facility are discussed.

  16. Health Benefits of Animal Research: The Dog as a Research Subject.

    ERIC Educational Resources Information Center

    Gay, William I.

    1984-01-01

    Discusses the role of dogs in research, considering their use in studies related to: behavior; aging; anesthesia; gastrointestinal surgery; the brain; organ transplants; radiobiology; trauma and shock; arterial diseases; hemophelia; ophthalmology; diabetes; nutrition; cancer; lupus; cyclic neutropenia; thyroiditis; hepatitis; skeletal system,…

  17. American Association of Dental Schools Curricular Guidelines for Oral Radiology.

    ERIC Educational Resources Information Center

    Journal of Dental Education, 1980

    1980-01-01

    Oral radiology curricular guidelines developed by the American Association of Dental Schools are provided. The guidelines describe minimal conditions under which a satisfactory educational experience can be offered. Principles of x-radiation, radiobiological concepts, radiological health, radiographic technique, radiographic quality, and darkroom…

  18. Water versus DNA: New insights into proton track-structure modeling in radiobiology and radiotherapy

    DOE PAGES

    Champion, Christophe; Quinto, Michele A.; Monti, Juan M.; ...

    2015-09-25

    Water is a common surrogate of DNA for modelling the charged particle-induced ionizing processes in living tissue exposed to radiations. The present study aims at scrutinizing the validity of this approximation and then revealing new insights into proton-induced energy transfers by a comparative analysis between water and realistic biological medium. In this context, a self-consistent quantum mechanical modelling of the ionization and electron capture processes is reported within the continuum distorted wave-eikonal initial state framework for both isolated water molecules and DNA components impacted by proton beams. Their respective probability of occurrence-expressed in terms of total cross sections-as well asmore » their energetic signature (potential and kinetic) are assessed in order to clearly emphasize the differences existing between realistic building blocks of living matter and the controverted water-medium surrogate. Thus the consequences in radiobiology and radiotherapy will be discussed in particular in view of treatment planning refinement aiming at better radiotherapy strategies.« less

  19. Research activities at the Loma Linda University and Proton Treatment Facility--an overview

    NASA Technical Reports Server (NTRS)

    Nelson, G. A.; Green, L. M.; Gridley, D. S.; Archambeau, J. O.; Slater, J. M.

    2001-01-01

    The Loma Linda University (LLU) Radiobiology Program coordinates basic research and proton beam service activities for the university and extramural communities. The current focus of the program is on the biological and physical properties of protons and the operation of radiobiology facilities for NASA-sponsored projects. The current accelerator, supporting facilities and operations are described along with a brief review of extramural research projects supported by the program. These include space craft electronic parts and shielding testing as well as tumorigenesis and animal behavior experiments. An overview of research projects currently underway at LLU is also described. These include: 1) acute responses of the C57Bl/6 mouse immune system, 2) modulation of gene expression in the nematode C. elegans and rat thyroid cells, 3) quantitation of dose tolerance in rat CNS microvasculature, 4) behavioral screening of whole body proton and iron ion-irradiated C57Bl/6 mice, and 5) investigation of the role of cell integration into epithelial structures on responses to radiation.

  20. Water versus DNA: new insights into proton track-structure modelling in radiobiology and radiotherapy.

    PubMed

    Champion, C; Quinto, M A; Monti, J M; Galassi, M E; Weck, P F; Fojón, O A; Hanssen, J; Rivarola, R D

    2015-10-21

    Water is a common surrogate of DNA for modelling the charged particle-induced ionizing processes in living tissue exposed to radiations. The present study aims at scrutinizing the validity of this approximation and then revealing new insights into proton-induced energy transfers by a comparative analysis between water and realistic biological medium. In this context, a self-consistent quantum mechanical modelling of the ionization and electron capture processes is reported within the continuum distorted wave-eikonal initial state framework for both isolated water molecules and DNA components impacted by proton beams. Their respective probability of occurrence-expressed in terms of total cross sections-as well as their energetic signature (potential and kinetic) are assessed in order to clearly emphasize the differences existing between realistic building blocks of living matter and the controverted water-medium surrogate. Consequences in radiobiology and radiotherapy will be discussed in particular in view of treatment planning refinement aiming at better radiotherapy strategies.

  1. Radiosurgery with photons or protons for benign and malignant tumours of the skull base: a review.

    PubMed

    Amichetti, Maurizio; Amelio, Dante; Minniti, Giuseppe

    2012-12-14

    Stereotactic radiosurgery (SRS) is an important treatment option for intracranial lesions. Many studies have shown the effectiveness of photon-SRS for the treatment of skull base (SB) tumours; however, limited data are available for proton-SRS.Several photon-SRS techniques, including Gamma Knife, modified linear accelerators (Linac) and CyberKnife, have been developed and several studies have compared treatment plan characteristics between protons and photons.The principles of classical radiobiology are similar for protons and photons even though they differ in terms of physical properties and interaction with matter resulting in different dose distributions.Protons have special characteristics that allow normal tissues to be spared better than with the use of photons, although their potential clinical superiority remains to be demonstrated.A critical analysis of the fundamental radiobiological principles, dosimetric characteristics, clinical results, and toxicity of proton- and photon-SRS for SB tumours is provided and discussed with an attempt of defining the advantages and limits of each radiosurgical technique.

  2. Response of thermoluminescent lithium fluoride (TLD-100) to photon beams of 275, 400, 500, 600, 730, 900, 1200, 1500, and 2500 eV.

    PubMed

    Carrillo, R E; Pearson, D W; DeLuca, P M; MacKay, J F; Lagally, M G

    1994-11-01

    LiF:Mg,Ti (TLD-100) extruded ribbons and cleaved crystals were exposed to monoenergetic photons of 275-2550 eV energy to determine their potential usefulness as radiation dosimeters for radiobiology experiments at these energies. The radiation source was synchrotron radiation from the 1 GeV electron storage ring, Aladdin. The authors report TLD response and glow curves for He- and air-annealed dosimeters. The undesirable effects of air annealing increase with decreasing photon penetration in the dosimeter. Under certain experimental conditions, UV radiation produced anomalous bleaching of high-temperature traps. The crystals and the chips presented a supralinear response, Supralinearity factors were determined to be of the order of 1.5 for crystals, and 1.7 for the chips. The authors' results indicate that TLDs are a reliable means to monitor the total energy deposited in irradiated cells and are now used routinely for radiobiology cell irradiations.

  3. Applications of amorphous track models in radiation biology

    NASA Technical Reports Server (NTRS)

    Cucinotta, F. A.; Nikjoo, H.; Goodhead, D. T.; Wilson, J. W. (Principal Investigator)

    1999-01-01

    The average or amorphous track model uses the response of a system to gamma-rays and the radial distribution of dose about an ion's path to describe survival and other cellular endpoints from proton, heavy ion, and neutron irradiation. This model has been used for over 30 years to successfully fit many radiobiology data sets. We review several extensions of this approach that address objections to the original model, and consider applications of interest in radiobiology and space radiation risk assessment. In the light of present views of important cellular targets, the role of target size as manifested through the relative contributions from ion-kill (intra-track) and gamma-kill (inter-track) remains a critical question in understanding the success of the amorphous track model. Several variations of the amorphous model are discussed, including ones that consider the radial distribution of event-sizes rather than average electron dose, damage clusters rather than multiple targets, and a role for repair or damage processing.

  4. Cell kill by megavoltage protons with high LET.

    PubMed

    Kuperman, Vadim Y

    2016-07-21

    The aim of the current study is to develop a radiobiological model which describes the effect of linear energy transfer (LET) on cell survival and relative biological effectiveness (RBE) of megavoltage protons. By assuming the existence of critical sites within a cell, analytical expression for cell survival S as a function of LET is derived. The obtained results indicate that in cases where dose per fraction is small, [Formula: see text] is a linear-quadratic (LQ) function of dose while both alpha and beta radio-sensitivities are non-linearly dependent on LET. In particular, in the current model alpha increases with increasing LET while beta decreases. Conversely, in the case of large dose per fraction, the LQ dependence of [Formula: see text] on dose is invalid. The proposed radiobiological model predicts cell survival probability and RBE which, in general, deviate from the results obtained by using conventional LQ formalism. The differences between the LQ model and that described in the current study are reflected in the calculated RBE of protons.

  5. Radiosurgery with photons or protons for benign and malignant tumours of the skull base: a review

    PubMed Central

    2012-01-01

    Stereotactic radiosurgery (SRS) is an important treatment option for intracranial lesions. Many studies have shown the effectiveness of photon-SRS for the treatment of skull base (SB) tumours; however, limited data are available for proton-SRS. Several photon-SRS techniques, including Gamma Knife, modified linear accelerators (Linac) and CyberKnife, have been developed and several studies have compared treatment plan characteristics between protons and photons. The principles of classical radiobiology are similar for protons and photons even though they differ in terms of physical properties and interaction with matter resulting in different dose distributions. Protons have special characteristics that allow normal tissues to be spared better than with the use of photons, although their potential clinical superiority remains to be demonstrated. A critical analysis of the fundamental radiobiological principles, dosimetric characteristics, clinical results, and toxicity of proton- and photon-SRS for SB tumours is provided and discussed with an attempt of defining the advantages and limits of each radiosurgical technique. PMID:23241206

  6. Review: A Systematic Review of Quality of Life Measures for People with Intellectual Disabilities and Challenging Behaviours

    ERIC Educational Resources Information Center

    Townsend-White, C.; Pham, A. N. T.; Vassos, M. V.

    2012-01-01

    Background: The quality of life (QOL) construct is proposed as a method to assess service outcomes for people utilising disability services. With this in mind, the aim of this study was to conduct a systematic review of available QOL measures for people with intellectual disability (ID) to pinpoint psychometrically sound measures that can be…

  7. High dose-per-pulse electron beam dosimetry: Commissioning of the Oriatron eRT6 prototype linear accelerator for preclinical use.

    PubMed

    Jaccard, Maud; Durán, Maria Teresa; Petersson, Kristoffer; Germond, Jean-François; Liger, Philippe; Vozenin, Marie-Catherine; Bourhis, Jean; Bochud, François; Bailat, Claude

    2018-02-01

    The Oriatron eRT6 is an experimental high dose-per-pulse linear accelerator (linac) which was designed to deliver an electron beam with variable dose-rates, ranging from a few Gy/min up to hundreds of Gy/s. It was built to study the radiobiological effects of high dose-per-pulse/dose-rate electron beam irradiation, in the context of preclinical and cognitive studies. In this work, we report on the commissioning and beam monitoring of the Oriatron eRT6 prototype linac. The beam was characterized in different steps. The output stability was studied by performing repeated measurements over a period of 20 months. The relative output variations caused by changing beam parameters, such as the temporal electron pulse width, the pulse repetition frequency and the pulse amplitude were also analyzed. Finally, depth dose curves and field sizes were measured for two different beam settings, resulting in one beam with a conventional radiotherapy dose-rate and one with a much higher dose-rate. Measurements were performed with Gafchromic EBT3 films and with a PTW Advanced Markus ionization chamber. In addition, we developed a beam current monitoring system based on the signals from an induction torus positioned at the beam exit of the waveguide and from a graphite beam collimator. The stability of the output over repeated measurements was found to be good, with a standard deviation smaller than 1%. However, non-negligible day-to-day variations of the beam output were observed. Those output variations showed different trends depending on the dose-rate. The analysis of the relative output variation as a function of various beam parameters showed that in a given configuration, the dose-rate could be reliably varied over three orders of magnitude. Interdependence effects on the output variation between the parameters were also observed. The beam energy and field size were found to be slightly dose-rate-dependent and suitable mainly for small animal irradiation. The beam monitoring system was able to measure in a reproducible way the total charge of electrons that exit the machine, as long as the electron pulse amplitude remains above a given threshold. Furthermore, we were able to relate the charge measured with the monitoring system to the absorbed dose in a solid water phantom. The Oriatron eRT6 was successfully commissioned for preclinical use and is currently in full operation, with studies being performed on the radiobiological effects of high dose-per-pulse irradiation. © 2017 American Association of Physicists in Medicine.

  8. Health Benefits of Animal Research: The Mouse in Biomedical Research.

    ERIC Educational Resources Information Center

    Jonas, Albert M.

    1984-01-01

    Traces the history of using mice for medical research and discusses the benefits of using these animals for studies in bacteriology, virology, genetics (considering X-linked genetic homologies between mice and humans), molecular biology, immunology, hematology, immune response disorders, oncology, radiobiology, pharmacology, behavior genetics,…

  9. Very High Dose-Rate Radiobiology and Radiation Therapy for Lung Cancer

    DTIC Science & Technology

    2015-02-01

    most dramatic example is stereotactic ablative radiotherapy ( SABR )/ stereotactic body radiation therapy (SBRT), highly focused and accurate...significant motion, thus increasing the precision and accuracy of lung SABR /SBRT. Objective: We propose to develop a new type of RT system for early stage

  10. Science Goals in Radiation Protection for Exploration

    NASA Technical Reports Server (NTRS)

    Cucinotta, Francs A.

    2008-01-01

    Space radiation presents major challenges to future missions to the Earth s moon or Mars. Health risks of concern include cancer, degenerative and performance risks to the central nervous system, heart and lens, and the acute radiation syndromes. The galactic cosmic rays (GCR) contain high energy and charge (HZE) nuclei, which have been shown to cause qualitatively distinct biological damage compared to terresterial radiation, such as X-rays or gamma-rays, causing risk estimates to be highly uncertain. The biological effects of solar particle events (SPE) are similar to terresterial radiation except for their biological dose-rate modifiers; however the onset and size of SPEs are difficult to predict. The high energies of GCR reduce the effectiveness of shielding, while SPE s can be shielded however the current gap in radiobiological knowledge hinders optimization. Methods used to project risks on Earth must be modified because of the large uncertainties in projecting health risks from space radiation, and thus impact mission requirements and costs. We describe NASA s unique approach to radiation safety that applies probabilistic risk assessments and uncertainty based criteria within the occupational health program for astronauts and to mission design. The two terrestrial criteria of a point estimate of maximum acceptable level of risk and application of the principle of As Low As Reasonably Achievable (ALARA) are supplemented by a third requirement that protects against risk projection uncertainties using the upper 95% confidence level (CL) in radiation risk projection models. Exploration science goals in radiation protection are centered on ground-based research to achieve the necessary biological knowledge, and in the development of new technologies to improve SPE monitoring and optimize shielding. Radiobiology research is centered on a ground based program investigating the radiobiology of high-energy protons and HZE nuclei at the NASA Space Radiation Laboratory (NSRL) located at DoE s Brookhaven National Laboratory in Upton, NY. We describe recent NSRL results that are closing the knowledge gap in HZE radiobiology and improving exploration risk estimates. Linking probabilistic risk assessment to research goals makes it possible to express risk management objectives in terms of quantitative metrics, which include the number of days in space without exceeding a given risk level within well defined confidence limits, and probabilistic assessments of the effectiveness of design trade spaces such as material type, mass, solar cycle, crew selection criteria, and biological countermeasures. New research in SPE alert and risk assessment, individual radiation sensitivity, and biological countermeasure development are described.

  11. Exploring Sex Differences in Autistic Traits: A Factor Analytic Study of Adults with Autism

    ERIC Educational Resources Information Center

    Grove, Rachel; Hoekstra, Rosa A.; Wierda, Marlies; Begeer, Sander

    2017-01-01

    Research has highlighted potential differences in the phenotypic and clinical presentation of autism spectrum conditions across sex. Furthermore, the measures utilised to evaluate autism spectrum conditions may be biased towards the male autism phenotype. It is important to determine whether these instruments measure the autism phenotype…

  12. Accuracy verification of magnetic resonance imaging (MRI) technology for lower-limb prosthetic research: utilising animal soft tissue specimen and common socket casting materials.

    PubMed

    Safari, Mohammad Reza; Rowe, Philip; Buis, Arjan

    2012-01-01

    Lower limb prosthetic socket shape and volume consistency can be quantified using MRI technology. Additionally, MRI images of the residual limb could be used as an input data for CAD-CAM technology and finite element studies. However, the accuracy of MRI when socket casting materials are used has to be defined. A number of six, 46 mm thick, cross-sections of an animal leg were used. Three specimens were wrapped with Plaster of Paris (POP) and the other three with commercially available silicone interface liner. Data was obtained by utilising MRI technology and then the segmented images compared to corresponding calliper measurement, photographic imaging, and water suspension techniques. The MRI measurement results were strongly correlated with actual diameter, surface area, and volume measurements. The results show that the selected scanning parameters and the semiautomatic segmentation method are adequate enough, considering the limit of clinical meaningful shape and volume fluctuation, for residual limb volume and the cross-sectional surface area measurements.

  13. Accuracy Verification of Magnetic Resonance Imaging (MRI) Technology for Lower-Limb Prosthetic Research: Utilising Animal Soft Tissue Specimen and Common Socket Casting Materials

    PubMed Central

    Safari, Mohammad Reza; Rowe, Philip; Buis, Arjan

    2012-01-01

    Lower limb prosthetic socket shape and volume consistency can be quantified using MRI technology. Additionally, MRI images of the residual limb could be used as an input data for CAD-CAM technology and finite element studies. However, the accuracy of MRI when socket casting materials are used has to be defined. A number of six, 46 mm thick, cross-sections of an animal leg were used. Three specimens were wrapped with Plaster of Paris (POP) and the other three with commercially available silicone interface liner. Data was obtained by utilising MRI technology and then the segmented images compared to corresponding calliper measurement, photographic imaging, and water suspension techniques. The MRI measurement results were strongly correlated with actual diameter, surface area, and volume measurements. The results show that the selected scanning parameters and the semiautomatic segmentation method are adequate enough, considering the limit of clinical meaningful shape and volume fluctuation, for residual limb volume and the cross-sectional surface area measurements. PMID:22619599

  14. Evaluation of the radiobiological gamma index with motion interplay in tangential IMRT breast treatment

    PubMed Central

    Sumida, Iori; Yamaguchi, Hajime; Das, Indra J.; Kizaki, Hisao; Aboshi, Keiko; Tsujii, Mari; Yamada, Yuji; Tamari, Kiesuke; Suzuki, Osamu; Seo, Yuji; Isohashi, Fumiaki; Yoshioka, Yasuo; Ogawa, Kazuhiko

    2016-01-01

    The purpose of this study was to evaluate the impact of the motion interplay effect in early-stage left-sided breast cancer intensity-modulated radiation therapy (IMRT), incorporating the radiobiological gamma index (RGI). The IMRT dosimetry for various breathing amplitudes and cycles was investigated in 10 patients. The predicted dose was calculated using the convolution of segmented measured doses. The physical gamma index (PGI) of the planning target volume (PTV) and the organs at risk (OAR) was calculated by comparing the original with the predicted dose distributions. The RGI was calculated from the PGI using the tumor control probability (TCP) and the normal tissue complication probability (NTCP). The predicted mean dose and the generalized equivalent uniform dose (gEUD) to the target with various breathing amplitudes were lower than the original dose (P < 0.01). The predicted mean dose and gEUD to the OARs with motion were higher than for the original dose to the OARs (P < 0.01). However, the predicted data did not differ significantly between the various breathing cycles for either the PTV or the OARs. The mean RGI gamma passing rate for the PTV was higher than that for the PGI (P < 0.01), and for OARs, the RGI values were higher than those for the PGI (P < 0.01). The gamma passing rates of the RGI for the target and the OARs other than the contralateral lung differed significantly from those of the PGI under organ motion. Provided an NTCP value <0.05 is considered acceptable, it may be possible, by taking breathing motion into consideration, to escalate the dose to achieve the PTV coverage without compromising the TCP. PMID:27534793

  15. Importance of dosimetry protocol for cell irradiation on a low X-rays facility and consequences for the biological response.

    PubMed

    Dos Santos, Morgane; Paget, Vincent; Ben Kacem, Mariam; Trompier, François; Benadjaoud, Mohamed Amine; François, Agnès; Guipaud, Olivier; Benderitter, Marc; Milliat, Fabien

    2018-06-01

    The main objective of radiobiology is to establish links between doses and radiation-induced biological effects. In this context, well-defined dosimetry protocols are crucial to the determination of experimental protocols. This work proposes a new dosimetry protocol for cell irradiation in a SARRP and shows the importance of the modification of some parameters defined in dosimetry protocol for physical dose and biological outcomes. Once all parameters of the configuration were defined, dosimetry measurements with ionization chambers and EBT3 films were performed to evaluate the dose rate and the attenuation due to the cell culture medium. To evaluate the influence of changes in cell culture volume and/or additional filtration, 6-well plates containing EBT3 films with water were used to determine the impact on the physical dose at 80 kV. Then, experiments with the same irradiation conditions were performed by replacing EBT3 films by HUVECs. The biological response was assessed using clonogenic assay. Using a 0.15 mm copper filter lead to a variation of +1% using medium thickness of 0.104 cm to -8% using a medium thickness of 0.936 cm on the physical dose compare to the reference condition (0.313 cm). For the 1 mm aluminum filter, a variation of +8 to -40% for the same medium thickness conditions has been observed. Cells irradiated in the same conditions showed significant differences in survival fraction, corroborating the effects of dosimetric changes on physical dose. This work shows the importance of dosimetry in radiobiology studies and the need of an accurate description of the dosimetry protocol used for irradiation.

  16. Comparison of the helical tomotherapy against the multileaf collimator-based intensity-modulated radiotherapy and 3D conformal radiation modalities in lung cancer radiotherapy

    PubMed Central

    Mavroidis, P; Shi, C; Plataniotis, G A; Delichas, M G; Costa Ferreira, B; Rodriguez, S; Lind, B K; Papanikolaou, N

    2011-01-01

    Objectives The aim of this study was to compare three-dimensional (3D) conformal radiotherapy and the two different forms of IMRT in lung cancer radiotherapy. Methods Cases of four lung cancer patients were investigated by developing a 3D conformal treatment plan, a linac MLC-based step-and-shoot IMRT plan and an HT plan for each case. With the use of the complication-free tumour control probability (P+) index and the uniform dose concept as the common prescription point of the plans, the different treatment plans were compared based on radiobiological measures. Results The applied plan evaluation method shows the MLC-based IMRT and the HT treatment plans are almost equivalent over the clinically useful dose prescription range; however, the 3D conformal plan inferior. At the optimal dose levels, the 3D conformal treatment plans give an average P+ of 48.1% for a effective uniform dose to the internal target volume (ITV) of 62.4 Gy, whereas the corresponding MLC-based IMRT treatment plans are more effective by an average ΔP+ of 27.0% for a Δ effective uniform dose of 16.3 Gy. Similarly, the HT treatment plans are more effective than the 3D-conformal plans by an average ΔP+ of 23.8% for a Δ effective uniform dose of 11.6 Gy. Conclusion A radiobiological treatment plan evaluation can provide a closer association of the delivered treatment with the clinical outcome by taking into account the dose–response relations of the irradiated tumours and normal tissues. The use of P – effective uniform dose diagrams can complement the traditional tools of evaluation to compare and effectively evaluate different treatment plans. PMID:20858664

  17. Low utilisation of diabetes medicines in Iran, despite their affordability (2000–2012): a time-series and benchmarking study

    PubMed Central

    Sarayani, Amir; Rashidian, Arash; Gholami, Kheirollah

    2014-01-01

    Objectives Diabetes is a major public health concern worldwide, particularly in low-income and middle-income countries (LMICs). Limited data exist on the status of access to diabetes medicines in LMICs. We assessed the utilisation and affordability of diabetes medicines in Iran as a middle-income country. Design We used a retrospective time-series design (2000–2012) and assessed national diabetes medicines’ utilisation using pharmaceuticals wholesale data. Methods We calculated defined daily dose consumptions per population days (DDDs/1000 inhabitants/day; DIDs) indicator. Findings were benchmarked with data from Organization for Economic Co-operation and Development (OECD) countries. We also employed Drug Utilization-90% (DU-90) method to compare DU-90s with the Essential Medicines List published by the WHO. We measured affordability using number of minimum daily wage required to purchase a treatment course for 1 month. Results Diabetes medicines’ consumption increased from 4.47 to 33.54 DIDs. The benchmarking showed that medicines’ utilisation in Iran in 2011 was only 54% of the median DIDs of 22 OECD countries. Oral hypoglycaemic agents consisted over 80% of use throughout the study period. Regular and isophane insulin (NPH), glibenclamide, metformin and gliclazide were the DU-90 drugs in 2012. Metformin, glibenclamide and regular/NPH insulin combination therapy were affordable throughout the study period (∼0.4, ∼0.1, ∼0.3 of minimum daily wage, respectively). While the affordability of novel insulin preparations improved over time, they were still unaffordable in 2012. Conclusions The utilisation of diabetes medicines was relatively low, perhaps due to underdiagnosis and inadequate management of patients with diabetes. This had occurred despite affordability of essential diabetes medicines in Iran. Appropriate policies are required to address the underutilisation of diabetes medicines in Iran. PMID:25324322

  18. Radiobiological aspects of high altitude flight : relative biological effectiveness of fast neutrons in suppressing immune capacity to an infective agent.

    DOT National Transportation Integrated Search

    1978-02-01

    We investigated the relative biological effectiveness (RBE) of fast neutrons compared with X-rays in impeding development of immunity to an infective agent, the intestinal cestode Hymenolepis nana. Mice were irradiated with neutrons or X-rays and 2 d...

  19. 42 CFR Appendix E to Part 75 - Standards for Accreditation of Educational Programs for Radiation Therapy Technologists

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... universities; (b) Hospitals, clinics, or autonomous radiation oncology centers meeting the criteria for major... structure and function; (f) Oncologic pathology; (g) Radiation oncology; (h) Radiobiology; (i) Mathematics; (j) Radiation physics; (k) Radiation protection; (l) Radiation oncology technique; (m) Radiographic...

  20. 42 CFR Appendix E to Part 75 - Standards for Accreditation of Educational Programs for Radiation Therapy Technologists

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... universities; (b) Hospitals, clinics, or autonomous radiation oncology centers meeting the criteria for major... structure and function; (f) Oncologic pathology; (g) Radiation oncology; (h) Radiobiology; (i) Mathematics; (j) Radiation physics; (k) Radiation protection; (l) Radiation oncology technique; (m) Radiographic...

  1. 42 CFR Appendix E to Part 75 - Standards for Accreditation of Educational Programs for Radiation Therapy Technologists

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... universities; (b) Hospitals, clinics, or autonomous radiation oncology centers meeting the criteria for major... structure and function; (f) Oncologic pathology; (g) Radiation oncology; (h) Radiobiology; (i) Mathematics; (j) Radiation physics; (k) Radiation protection; (l) Radiation oncology technique; (m) Radiographic...

  2. 42 CFR Appendix E to Part 75 - Standards for Accreditation of Educational Programs for Radiation Therapy Technologists

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... universities; (b) Hospitals, clinics, or autonomous radiation oncology centers meeting the criteria for major... structure and function; (f) Oncologic pathology; (g) Radiation oncology; (h) Radiobiology; (i) Mathematics; (j) Radiation physics; (k) Radiation protection; (l) Radiation oncology technique; (m) Radiographic...

  3. Primary Blast Injuries in the Open and in Foxholes Resulting from Nuclear Type Detonations

    DTIC Science & Technology

    1991-07-01

    within a few hours after blast are probably caused by suffocation from blood and fluids obstructing the airways and from intra- abdominal...ATT’N: _-COMIPAQ •.. • - i .• :_ ... . - ARMED FORCES RADIOBIOLOGY RSCH INST ATTN: DEPT OF RADIATION BIOCHEMISTRY INTERSERVICE NUCLEAR WEAPONS SCHOOL

  4. Biology Division annual progress report for period ending December 31, 1968

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1969-07-01

    Brief summaries are presented of research in progress in the fields of radiobiology, genetics, hematology, immunology, physsiology, biochemistry, bacteriology, enzymology, microbiology, photosynthesis, biophysics, radiation protection, and related fields. A list is included of 212 publications in the world literature that report results of completed studies. (CH)

  5. Research at the Institute of Forest Genetics, Rhinelander, Wisconsin.

    Treesearch

    Richard M. Jeffers

    1971-01-01

    Reports research at the Forest Genetics Institute in Rhinelander, Wisconsin, since its beginning in 1957. Describes the physical plant, study objectives, and work program. The latter includes studies of seed source, inheritance in white spruce, disease and insect resistance, interspecific hybridization, radiation genetics and radiobiology, vegetative propagation,...

  6. Women's autonomy and reproductive health care utilisation: empirical evidence from Tajikistan.

    PubMed

    Kamiya, Yusuke

    2011-10-01

    Women's autonomy is widely considered to be a key to improving maternal health in developing countries, whereas there is no consistent empirical evidence to support this claim. This paper examines whether or not and how women's autonomy within the household affects the use of reproductive health care, using a household survey data from Tajikistan. Estimation is performed by the bivariate probit model whereby woman's use of health services and the level of women's autonomy are recursively and simultaneously determined. The data is from a sample of women aged 15-49 from the Tajikistan Living Standard Measurement Survey 2007. Women's autonomy as measured by women's decision-making on household financial matters increase the likelihood that a woman receives antenatal and delivery care, whilst it has a negative effect on the probability of attending to four or more antenatal consultations. The hypothesis that women's autonomy and reproductive health care utilisation are independently determined is rejected for most of the estimation specifications, indicating the importance of taking into account the endogenous nature of women's autonomy when assessing its effect on health care use. The empirical results reconfirm the assertion that women's status within the household is closely linked to reproductive health care utilisation in developing countries. Policymakers therefore need not only to implement not only direct health interventions but also to focus on broader social policies which address women's empowerment. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  7. The Ottawa ankle rules for the use of diagnostic X-ray in after hours medical centres in New Zealand.

    PubMed

    Wynn-Thomas, Simon; Love, Tom; McLeod, Deborah; Vernall, Sue; Kljakovic, Marjan; Dowell, Antony; Durham, John

    2002-09-27

    The aims of this study were to measure baseline use of Ottawa ankle rules (OAR), validate the OAR and, if appropriate, explore the impact of implementing the Rules on X-ray rates in a primary care, after hours medical centre setting. General practitioners (GPs) were surveyed to find their awareness of ankle injury guidelines. Data concerning diagnosis and X-ray utilisation were collected prospectively for patients presenting with ankle injuries to two after hours medical centres. The OAR were applied retrospectively, and the sensitivity and specificity of the OAR were compared with GPs clinical judgement in ordering X-rays. The outcome measures were X-ray utilisation and diagnosis of fracture. Awareness of the OAR was low. The sensitivity of the OAR for diagnosis of fractures was 100% (95% CI: 75.3 - 100) and the specificity was 47% (95% CI: 40.5 - 54.5). The sensitivity of GPs clinical judgement was 100% (95% CI: 75.3 - 100) and the specificity was 37% (95% CI: 30.2 - 44.2). Implementing the OAR would reduce X-ray utilisation by 16% (95% CI: approx 10.8 - 21.3). The OAR are valid in a New Zealand primary care setting. Further implementation of the rules would result in some reduction of X-rays ordered for ankle injuries, but less than the reduction found in previous studies.

  8. Utilisation of cancer screening services by disabled women in Chile

    PubMed Central

    Rotarou, Elena S.

    2017-01-01

    Background Research has shown that women with disabilities face additional challenges in accessing and using healthcare services compared to non-disabled women. However, relatively little is known about the utilisation of cancer screening services for women with disabilities. This study addresses this gap by examining the utilisation of the Papanicolaou test and mammography for disabled women in Chile. Methods We used cross-sectional data, taken from a 2015 nationally-representative survey. Initially, we employed logistic regressions to test for differences in utilisation rates for the Papanicolaou test (66,281 observations) and the mammogram (35,294 observations) between disabled and non-disabled women. Next, logistic regressions were used to investigate the demographic, socioeconomic, and health-related factors affecting utilisation rates for cancer screening services for disabled women (sample sizes: 5,823 observations for the Papanicolaou test and 5,731 observations for the mammogram). Results Disabled women were less likely to undergo screening tests than non-disabled women. For the Papanicolaou test and mammography, the multivariable regression models showed that living in rural areas, having higher education, being affiliated with a private health insurance company, giving a good health self-assessment score, and being under medical treatment for other illnesses were associated with higher utilisation rates. On the other hand, being single, inactive with regard to employment, and having a better income were linked with lower utilisation. While utilisation rates for both disabled and non-disabled women have increased since 2006, the utilisation disparity has slightly increased. Conclusions This study shows the influence of various factors in the utilisation rates of preventive cancer screening services for disabled women. To develop effective initiatives targeting inequalities in the utilisation of cancer screening tests, it is important to move beyond an exclusively single-disease approach and acknowledge the complexity of the patient population. PMID:28459874

  9. Utilisation of cancer screening services by disabled women in Chile.

    PubMed

    Sakellariou, Dikaios; Rotarou, Elena S

    2017-01-01

    Research has shown that women with disabilities face additional challenges in accessing and using healthcare services compared to non-disabled women. However, relatively little is known about the utilisation of cancer screening services for women with disabilities. This study addresses this gap by examining the utilisation of the Papanicolaou test and mammography for disabled women in Chile. We used cross-sectional data, taken from a 2015 nationally-representative survey. Initially, we employed logistic regressions to test for differences in utilisation rates for the Papanicolaou test (66,281 observations) and the mammogram (35,294 observations) between disabled and non-disabled women. Next, logistic regressions were used to investigate the demographic, socioeconomic, and health-related factors affecting utilisation rates for cancer screening services for disabled women (sample sizes: 5,823 observations for the Papanicolaou test and 5,731 observations for the mammogram). Disabled women were less likely to undergo screening tests than non-disabled women. For the Papanicolaou test and mammography, the multivariable regression models showed that living in rural areas, having higher education, being affiliated with a private health insurance company, giving a good health self-assessment score, and being under medical treatment for other illnesses were associated with higher utilisation rates. On the other hand, being single, inactive with regard to employment, and having a better income were linked with lower utilisation. While utilisation rates for both disabled and non-disabled women have increased since 2006, the utilisation disparity has slightly increased. This study shows the influence of various factors in the utilisation rates of preventive cancer screening services for disabled women. To develop effective initiatives targeting inequalities in the utilisation of cancer screening tests, it is important to move beyond an exclusively single-disease approach and acknowledge the complexity of the patient population.

  10. Long-term accumulation and microdistribution of uranium in the bone and marrow of beagle dog.

    PubMed

    Arruda-Neto, J D T; Manso Guevara, M V; Nogueira, G P; Taricano, I D; Saiki, M; Zamboni, C B; Bonamin, L V; Camargo, S P; Cestari, A C; Deppman, A; Garcia, F; Gouveia, A N; Guzman, F; Helene, O A M; Jorge, S A C; Likhachev, V P; Martins, M N; Mesa, J; Rodriguez, O; Vanin, V R

    2004-08-01

    The accumulation and microdistribution of uranium in the bone and marrow of Beagle dogs were determined by both neutron activation and neutron-fission analysis. The experiment started immediately after the weaning period, lasting till maturity. Two animal groups were fed daily with uranyl nitrate at concentrations of 20 and 100 microg g(-1) food. Of the two measuring techniques, uranium accumulated along the marrow as much as in the bone, contrary to the results obtained with single, acute doses. The role played by this finding for the evaluation of radiobiological long-term risks is discussed. It was demonstrated, by means of a biokinetical approach, that the long-term accumulation of uranium in bone and marrow could be described by a piling up of single dose daily incorporation.

  11. Determination of the asphaltene and carboxylic acid content of a heavy oil using a microfluidic device.

    PubMed

    Bowden, Stephen A; Wilson, Rab; Parnell, John; Cooper, Jonathan M

    2009-03-21

    Heavy oil utilisation is set to increase over the coming decades as reserves of conventional oil decline. Heavy oil differs from conventional oil in containing relatively large quantities of asphaltene and carboxylic acids. The proportions of these compounds greatly influence how oil behaves during production and its utilisation as a fuel or feedstock. We report the development of a microfluidic technique, based on a H-cell, that can extract the carboxylic acid components of an oil and assess its asphaltene content. Ultimately this technology could yield a field-deployable device capable of performing measurements that facilitate improved resource management at the point of resource-extraction.

  12. Determinants of maternal health care services utilization in Pakistan: evidence from Pakistan demographic and health survey, 2012-13.

    PubMed

    Zakar, Rubeena; Zakar, Muhammad Zakria; Aqil, Nauman; Chaudhry, Ashraf; Nasrullah, Muazzam

    2017-04-01

    The aim of this study was to determine the association between maternal utilisation of health-care services and socio-demographic factors among reproductive-age women in Pakistan. We used the sample of ever-married reproductive-age women (n = 7446) from the Pakistan Demographic and Health Survey (PDHS), 2012-13. We measured maternal utilisation of health-care services by using three dependent variables: number of antenatal care (ANC) visits, delivery assistance by a skilled health provider, and delivery in a health-care facility. Around 36.6% of women had made four or more ANC visits, 59% had received assistance from skilled health providers during delivery, and 55.3% had given birth in a health-care facility. On multivariable logistic regression, all three variables were positively associated with education and wealth, and negatively associated with birth order and women's autonomy. Policymakers and health planners may use our findings to develop efficient strategies, particularly for uneducated women and those with poor economic status, to improve the utilisation of maternal health-care services in Pakistan.

  13. Do quality improvement systems improve health library services? A systematic review.

    PubMed

    Gray, Hannah; Sutton, Gary; Treadway, Victoria

    2012-09-01

    A turbulent financial and political climate requires health libraries to be more accountable than ever. Quality improvement systems are widely considered a 'good thing to do', but do they produce useful outcomes that can demonstrate value? To undertake a systematic review to identify which aspects of health libraries are being measured for quality, what tools are being used and what outcomes are reported following utilisation of quality improvement systems. Many health libraries utilise quality improvement systems without translating the data into service improvements. Included studies demonstrate that quality improvement systems produce valuable outcomes including a positive impact on strategic planning, promotion, new and improved services and staff development. No impact of quality improvement systems on library users or patients is reported in the literature. The literature in this area is sparse and requires updating. We recommend further primary research is conducted in health libraries focusing upon the outcomes of utilising quality improvement systems. An exploration of quality improvement systems in other library sectors may also provide valuable insight for health libraries. © 2012 The authors. Health Information and Libraries Journal © 2012 Health Libraries Group.

  14. Evaluation of swine fertilisation medium (SFM) efficiency in preserving spermatozoa quality during long-term storage in comparison to four commercial swine extenders.

    PubMed

    Fantinati, P; Zannoni, A; Bernardini, C; Forni, M; Tattini, A; Seren, E; Bacci, M L

    2009-02-01

    In pig production, artificial insemination is widely carried out and the use of fresh diluted semen is predominant. For this reason, there are increasing interests in developing new extenders and in establishing the optimal storage conditions for diluted spermatozoa. In the last few decades, we utilised a homemade diluent (swine fertilisation medium (SFM)) for spermatozoa manipulation and biotechnological application as the production of transgenic pigs utilising the sperm-mediated gene transfer technique. The purpose of the present study is therefore to analyse the ability of SFM, in comparison to four commercial extenders, in preserving the quality of diluted boar semen stored at 16.5°C till 15 days. We utilised some of the main predictive tests as objectively measured motility, acrosome and sperm membrane integrity, high mitochondrial membrane potential and pH. Based on our in vitro study, SFM could be declared as a good long-term extender, able to preserve spermatozoa quality as well as Androhep Enduraguard for up to 6 to 9 days and more.

  15. Heating Has No Effect on the Net Protein Utilisation from Egg Whites in Rats.

    PubMed

    Matsuoka, Ryosuke; Takahashi, Yayoi; Kimura, Mamoru; Masuda, Yasunobu; Kunou, Masaaki

    2017-01-01

    Egg whites (EW) are a good source of protein; however, they are typically heated prior to consumption. Therefore, we investigated the effects of different heating conditions on the protein utilisation rate of EW. Male Sprague-Dawley rats ( n = 36, 198 ± 1 g) were divided into six groups and fed American Institute of Nutrition-76 chow containing unheated EW, soft-boiled EW, boiled EW, milk whey protein, soybean protein, or no protein over a 10-day period using pair-feeding. Urine and faeces were sampled daily beginning on day 5 to measure nitrogen content and the net protein utilisation (NPU) rate. The soybean protein group had a significantly lower level of food intake and was thus excluded from subsequent analyses. The NPU value was similar among the unheated, soft-boiled, and boiled EW groups (97.5 ± 0.4, 96.5 ± 0.1, and 96.5 ± 0.7, resp.). The EW group values were significantly higher than the whey group values (90.5 ± 1.0). These results show that EW serve as a good source of protein, irrespective of heating.

  16. Association between health service utilisation of internal migrant children and parents’ acculturation in Guangdong, China: a cross-sectional study

    PubMed Central

    Peng, Bo-li; Zou, Guan-yang; Chen, Wen; Lin, Yan-wei; Ling, Li

    2018-01-01

    Objectives To assess the health service utilisation of internal migrant children in Guangdong, China, and to explore the association between children’s health service utilisation and their parents’ acculturation. Design Cross-sectional survey between April and May 2016. Setting Six society-run schools of Tianhe and Baiyun districts in Guangzhou City of China. Participants We recruited all students at grade 7 or 8 and one of their parents who resided in Guangzhou over 6 months without permanent registered residence (hukou) in Guangzhou (1161 pairs completed this survey). 258 children were ill within the past 2 weeks or during the last year. Main outcome measures The main outcome was self-reported health service utilisation. Logistic regression analysis was conducted to explore the association between children’s unmet needs for outpatient or inpatient service and their parents’ acculturation (categorised into high, middle and low groups). Results In total, 216 children, or 18.6% of the total subjects, were ill within the past 2 weeks and were in need of outpatient service; 94 children, or 8.1% of the total subjects, were in need of inpatient service. Among them, 17.6% and 46.8% of the migrant children had unmet needs for outpatient and inpatient services, respectively. After controlling for enabling resources and predisposing characteristics, migrant children with parents in the middle-acculturation group (adjusted OR=3.17, 95% CIs 1.2 to 8.3, P<0.05) were more likely to have an unmet outpatient need than high-acculturation or low-acculturation groups, although only statistically significant when comparing with the high-acculturation group. Stratified analysis suggested that this association could be moderated by their family economic status. Conclusions Our study suggested that the association between migrant children’s health service utilisation and their parents’ acculturation was complex and could be moderated by family economic status. Increasing the service utilisation among migrant children requires improving the acculturation and economic status of the parents of internal migrants. PMID:29331968

  17. Biophysical characterization of a relativistic proton beam for image-guided radiosurgery

    PubMed Central

    Yu, Zhan; Vanstalle, Marie; La Tessa, Chiara; Jiang, Guo-Liang; Durante, Marco

    2012-01-01

    We measured the physical and radiobiological characteristics of 1 GeV protons for possible applications in stereotactic radiosurgery (image-guided plateau-proton radiosurgery). A proton beam was accelerated at 1 GeV at the Brookhaven National Laboratory (Upton, NY) and a target in polymethyl methacrylate (PMMA) was used. Clonogenic survival was measured after exposures to 1–10 Gy in three mammalian cell lines. Measurements and simulations demonstrate that the lateral scattering of the beam is very small. The lateral dose profile was measured with or without the 20-cm plastic target, showing no significant differences up to 2 cm from the axis A large number of secondary swift protons are produced in the target and this leads to an increase of approximately 40% in the measured dose on the beam axis at 20 cm depth. The relative biological effectiveness at 10% survival level ranged between 1.0 and 1.2 on the beam axis, and was slightly higher off-axis. The very low lateral scattering of relativistic protons and the possibility of using online proton radiography during the treatment make them attractive for image-guided plateau (non-Bragg peak) stereotactic radiosurgery. PMID:22843629

  18. Fast and accurate Monte Carlo modeling of a kilovoltage X-ray therapy unit using a photon-source approximation for treatment planning in complex media.

    PubMed

    Zeinali-Rafsanjani, B; Mosleh-Shirazi, M A; Faghihi, R; Karbasi, S; Mosalaei, A

    2015-01-01

    To accurately recompute dose distributions in chest-wall radiotherapy with 120 kVp kilovoltage X-rays, an MCNP4C Monte Carlo model is presented using a fast method that obviates the need to fully model the tube components. To validate the model, half-value layer (HVL), percentage depth doses (PDDs) and beam profiles were measured. Dose measurements were performed for a more complex situation using thermoluminescence dosimeters (TLDs) placed within a Rando phantom. The measured and computed first and second HVLs were 3.8, 10.3 mm Al and 3.8, 10.6 mm Al, respectively. The differences between measured and calculated PDDs and beam profiles in water were within 2 mm/2% for all data points. In the Rando phantom, differences for majority of data points were within 2%. The proposed model offered an approximately 9500-fold reduced run time compared to the conventional full simulation. The acceptable agreement, based on international criteria, between the simulations and the measurements validates the accuracy of the model for its use in treatment planning and radiobiological modeling studies of superficial therapies including chest-wall irradiation using kilovoltage beam.

  19. Maternal health services utilisation by Kenyan adolescent mothers: Analysis of the Demographic Health Survey 2014.

    PubMed

    Banke-Thomas, Aduragbemi; Banke-Thomas, Oluwasola; Kivuvani, Mwikali; Ameh, Charles Anawo

    2017-06-01

    Kenya has one of the highest adolescent fertility rates in East-Africa, estimated at 106 births per 1000 females aged 15-19years. In addition to promoting safe sexual behaviour, utilisation of maternal health services (MHS) is essential to prevent poor outcomes of pregnancy and childbirth. To ensure optimum planning, particularly in the context of the Sustainable Development Goals, this study assesses the current service utilisation patterns of Kenyan adolescent mothers and the factors that affect this utilisation. Using data from the recently published 2014 Kenya Demographic Health Survey, we collected demographic and utilisation data of all three MHSs (antenatal care (ANC), skilled birth attendance (SBA) and postnatal care (PNC)) of adolescent mothers aged 15-19years. We then conducted bivariate and multivariate analyses to test associations between selected demographic and service utilisation variables. Our findings showed that half of Kenyan adolescent mothers have had their first birth by the age of 16. MHS utilisation rates amongst Kenyan adolescent mothers were 93%, 65%, 92% for ANC, SBA and PNC respectively. Mother's education, religion, ethnicity, place of residence, wealth quintile, mass media exposure, and geographical region were significant predictors for both ANC and SBA utilisation. Education level of partner was significant for ANC utilisation while parity was significant for both SBA and PNC. Adolescent MHS utilisation is not optimum in Kenya. More work that includes affordable care provision, cultural re-orientation, targeted mass-media campaigns and male involvement in care need to be done with emphasis on the most disadvantaged areas. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Outpatient echocardiography in the evaluation of innocent murmurs in children: utilisation benchmarking.

    PubMed

    Frias, Patricio A; Oster, Matthew; Daley, Patricia A; Boris, Jeffrey R

    2016-03-01

    We sought to benchmark the utilisation of echocardiography in the outpatient evaluation of heart murmurs by evaluating two large paediatric cardiology centres. Although criteria exist for appropriate use of echocardiography, there are no benchmarking data demonstrating its utilisation. We performed a retrospective cohort study of outpatients aged between 0 and 18 years at the Sibley Heart Center Cardiology and the Children's Hospital of Philadelphia Division of Cardiology, given a sole diagnosis of "innocent murmur" from 1 July, 2007 to 31 October, 2010. Using internal claims data, we compared the utilisation of echocardiography according to centre, patient age, and physician years of service. Of 23,114 eligible patients (Sibley Heart Center Cardiology: 12,815, Children's Hospital of Philadelphia Division of Cardiology: 10,299), 43.1% (Sibley Heart Center Cardiology: 45.2%, Children's Hospital of Philadelphia Division of Cardiology: 40.4%; p1-5 years had the lowest utilisation (32.7%). In two large paediatric cardiology practices, the overall utilisation of echocardiography by physicians with a sole diagnosis of innocent murmur was similar. There was significant and similar variability in utilisation by provider at both centres. Although these data serve as initial benchmarking, the variability in utilisation highlights the importance of appropriate use criteria.

  1. Performance of a Rotary Wing Air Brake in Supersonic Flow

    DTIC Science & Technology

    1947-05-18

    a pneumatic thrust measuring system (3) Strobotac and Audio Signal Generator for RPM measurements, (4) motion picture cameras and miscellaneous...produced by the head to keep the brake engaged. The " pneumatic thrust measuring system1* utilised the bellows described above to oppose the drag force...a brake , to prevent its rotation when desired. To release the brake it was necessary to inflate the internal thrust bellows, thereby disengaging

  2. Utilisation of the magnetic sensor in a smartphone for facile magnetostatics experiment: magnetic field due to electrical current in straight and loop wires

    NASA Astrophysics Data System (ADS)

    Septianto, R. D.; Suhendra, D.; Iskandar, F.

    2017-01-01

    This paper reports on the result of a research into the utilisation of a smartphone for the study of magnetostatics on the basis of experiments. The use of such a device gives great measurement result and thus it can replace magnetic sensor tools that are relatively expensive. For the best experimental result, firstly the position of the magnetic sensor in the smartphone has to be considered by way of value mapping of a magnetic field due to permanent magnet. The magnetostatics experiment investigated in this research was the measurement of magnetic field due to electrical currents in two shapes of wire, straight and looped. The current flow, the distance between the observation point and the wire, and the diameter of the loop were the variable parameters investigated to test the smartphone’s capabilities as a measurement tool. To evaluate the experimental results, the measured data were compared with theoretical values that were calculated by using both an analytical and a numerical approach. According to the experiment results, the measured data had good agreement with the results from the analytical and the numerical approach. This means that the use of the magnetic sensor in a smartphone in physics experiments is viable, especially for magnetic field measurement.

  3. Integrated nuclear data utilisation system for innovative reactors.

    PubMed

    Yamano, N; Hasegawa, A; Kato, K; Igashira, M

    2005-01-01

    A five-year research and development project on an integrated nuclear data utilisation system was initiated in 2002, for developing innovative nuclear energy systems such as accelerator-driven systems. The integrated nuclear data utilisation system will be constructed as a modular code system, which consists of two sub-systems: the nuclear data search and plotting sub-system, and the nuclear data processing and utilisation sub-system. The system will be operated with a graphical user interface in order to enable easy utilisation through the Internet by both nuclear design engineers and nuclear data evaluators. This paper presents an overview of the integrated nuclear data utilisation system, describes the development of a prototype system to examine the operability of the user interface and discusses specifications of the two sub-systems.

  4. 77 FR 68155 - The Armed Forces Radiobiology Research Institute TRIGA Reactor: Facility Operating License No. R-84

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-15

    ... a determination by the presiding officer that the filing demonstrates good cause by satisfying the... electronic storage media. Participants may not submit paper copies of their filings unless they seek an... through Friday, excluding government holidays. Participants who believe that they have a good cause for...

  5. Radiobiology of Large Animals

    DTIC Science & Technology

    1975-06-01

    efforts of James L. Thomas, Richard K. Marshall, and David E. Moore. iii L.,.„. mm mm ABSTRACT The LD5QS for sheep exposed to 60Co gamma rays at 0.9...25, 480-488 (1965). 7. J. S. Krebs, R. W. Brauer, and H. Kalbach , The estimation of the non-recuperable injury caused by ionizing radiation

  6. Cosmic ray heavy ion LET mapping for aluminum, silicon, and tissue targets

    NASA Technical Reports Server (NTRS)

    Stassinopoulos, E. G.; Barth, J. M.; Jordan, T. M.

    1987-01-01

    Linear energy transfer (LET) values in aluminum, silicon, and tissue targets have been calculated for 31 galactic cosmic ray ion species in eight different units. The values are described for single event upset (SEU) effect assessments or radiobiological evaluations. The data are presented in graphical and tabular form.

  7. Radiobiological study by using laser-driven proton beams

    NASA Astrophysics Data System (ADS)

    Yogo, A.; Sato, K.; Nishikino, M.; Mori, M.; Teshima, T.; Numasaki, H.; Murakami, M.; Demizu, Y.; Akagi, S.; Nagayama, S.; Ogura, K.; Sagisaka, A.; Orimo, S.; Nishiuchi, M.; Pirozhkov, A. S.; Ikegami, M.; Tampo, M.; Sakaki, H.; Suzuki, M.; Daito, I.; Oishi, Y.; Sugiyama, H.; Kiriyama, H.; Okada, H.; Kanazawa, S.; Kondo, S.; Shimomura, T.; Nakai, Y.; Tanoue, M.; Sugiyama, H.; Sasao, H.; Wakai, D.; Kawachi, T.; Nishimura, H.; Bolton, P. R.; Daido, H.

    2009-07-01

    Particle acceleration driven by high-intensity laser systems is widely attracting interest as a potential alternative to conventional ion acceleration, including ion accelerator applications to tumor therapy. Recent works have shown that a high intensity laser pulse can produce single proton bunches of a high current and a short pulse duration. This unique feature of laser-ion acceleration can lead to progress in the development of novel ion sources. However, there has been no experimental study of the biological effects of laser-driven ion beams. We describe in this report the first demonstrated irradiation effect of laser-accelerated protons on human lung cancer cells. In-vitro A549 cells are irradiated with a proton dose of 20 Gy, resulting in a distinct formation of γ-H2AX foci as an indicator of DNA double-strand breaks. This is a pioneering result that points to future investigations of the radiobiological effects of laser-driven ion beams. The laser-driven ion beam is apotential excitation source for time-resolved determination of hydroxyl (OH) radical yield, which will explore relationship between the fundamental chemical reactions of radiation effects and consequent biological processes.

  8. Light ion production for a future radiobiological facility at CERN: Preliminary studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stafford-Haworth, Joshua, E-mail: Joshua.Stafford-Haworth@cern.ch; John Adams Institute at Royal Holloway, University of London, Egham, Surrey TW20 0EX; Bellodi, Giulia

    2014-02-15

    Recent medical applications of ions such as carbon and helium have proved extremely effective for the treatment of human patients. However, before now a comprehensive study of the effects of different light ions on organic targets has not been completed. There is a strong desire for a dedicated facility which can produce ions in the range of protons to neon in order to perform this study. This paper will present the proposal and preliminary investigations into the production of light ions, and the development of a radiobiological research facility at CERN. The aims of this project will be presented alongmore » with the modifications required to the existing linear accelerator (Linac3), and the foreseen facility, including the requirements for an ion source in terms of some of the specification parameters and the flexibility of operation for different ion types. Preliminary results from beam transport simulations will be presented, in addition to some planned tests required to produce some of the required light ions (lithium, boron) to be conducted in collaboration with the Helmholtz-Zentrum für Materialien und Energie, Berlin.« less

  9. Transfer of Minibeam Radiation Therapy into a cost-effective equipment for radiobiological studies: a proof of concept.

    PubMed

    Prezado, Y; Dos Santos, M; Gonzalez, W; Jouvion, G; Guardiola, C; Heinrich, S; Labiod, D; Juchaux, M; Jourdain, L; Sebrie, C; Pouzoulet, F

    2017-12-11

    Minibeam radiation therapy (MBRT) is an innovative synchrotron radiotherapy technique able to shift the normal tissue complication probability curves to significantly higher doses. However, its exploration was hindered due to the limited and expensive beamtime at synchrotrons. The aim of this work was to develop a cost-effective equipment to perform systematic radiobiological studies in view of MBRT. Tumor control for various tumor entities will be addressable as well as studies to unravel the distinct biological mechanisms involved in normal and tumor tissues responses when applying MBRT. With that aim, a series of modifications of a small animal irradiator were performed to make it suitable for MBRT experiments. In addition, the brains of two groups of rats were irradiated. Half of the animals received a standard irradiation, the other half, MBRT. The animals were followed-up for 6.5 months. Substantial brain damage was observed in the group receiving standard RT, in contrast to the MBRT group, where no significant lesions were observed. This work proves the feasibility of the transfer of MBRT outside synchrotron sources towards a small animal irradiator.

  10. Medical management of radiation accidents: capabilities and deployment principles of the Bundeswehr Institute of Radiobiology.

    PubMed

    Dörr, Harald; Meineke, Viktor

    2012-10-01

    Radiation accidents are fortunately infrequent occurrences, but since their consequences can be very serious as in the Chernobyl and the Fukushima nuclear accidents, medical management of radiation accidents is of great importance. Besides several other tasks, medical management of radiation accidents is one of the key tasks of the Bundeswehr Institute of Radiobiology. Within a Task Force Unit for medical chemical, biological, radiological, and nuclear (CBRN) Defense, the institute provides designated personnel who will perform clinical investigations on the scene and will liaise with the institute, where different methods for biological dosimetry and dose reconstruction will be performed. The most important aspects of efficient medical management of radiation accidents are diagnosis of radiation-induced health damage, determination of the cause, dealing with contamination/incorporation, pathophysiological and therapeutic principles, preparatory planning, national and international cooperation and training. Military and non-military institutions have to work closely together when it comes to radiation accidents and since national resources are limited and could be exhausted, international networks can help to ensure medical treatment for radiation accident victims.

  11. Light ion production for a future radiobiological facility at CERN: preliminary studies.

    PubMed

    Stafford-Haworth, Joshua; Bellodi, Giulia; Küchler, Detlef; Lombardi, Alessandra; Röhrich, Jörg; Scrivens, Richard

    2014-02-01

    Recent medical applications of ions such as carbon and helium have proved extremely effective for the treatment of human patients. However, before now a comprehensive study of the effects of different light ions on organic targets has not been completed. There is a strong desire for a dedicated facility which can produce ions in the range of protons to neon in order to perform this study. This paper will present the proposal and preliminary investigations into the production of light ions, and the development of a radiobiological research facility at CERN. The aims of this project will be presented along with the modifications required to the existing linear accelerator (Linac3), and the foreseen facility, including the requirements for an ion source in terms of some of the specification parameters and the flexibility of operation for different ion types. Preliminary results from beam transport simulations will be presented, in addition to some planned tests required to produce some of the required light ions (lithium, boron) to be conducted in collaboration with the Helmholtz-Zentrum für Materialien und Energie, Berlin.

  12. Space Radiation and Manned Mission: Interface Between Physics and Biology

    NASA Astrophysics Data System (ADS)

    Hei, Tom

    2012-07-01

    The natural radiation environment in space consists of a mixed field of high energy protons, heavy ions, electrons and alpha particles. Interplanetary travel to the International Space Station and any planned establishment of satellite colonies on other solar system implies radiation exposure to the crew and is a major concern to space agencies. With shielding, the radiation exposure level in manned space missions is likely to be chronic, low dose irradiation. Traditionally, our knowledge of biological effects of cosmic radiation in deep space is almost exclusively derived from ground-based accelerator experiments with heavy ions in animal or in vitro models. Radiobiological effects of low doses of ionizing radiation are subjected to modulations by various parameters including bystander effects, adaptive response, genomic instability and genetic susceptibility of the exposed individuals. Radiation dosimetry and modeling will provide conformational input in areas where data are difficult to acquire experimentally. However, modeling is only as good as the quality of input data. This lecture will discuss the interdependent nature of physics and biology in assessing the radiobiological response to space radiation.

  13. Multimorbidity and healthcare utilisation among high-cost patients in the US Veterans Affairs Health Care System

    PubMed Central

    Zulman, Donna M; Pal Chee, Christine; Wagner, Todd H; Yoon, Jean; Cohen, Danielle M; Holmes, Tyson H; Ritchie, Christine; Asch, Steven M

    2015-01-01

    Objectives To investigate the relationship between multimorbidity and healthcare utilisation patterns among the highest cost patients in a large, integrated healthcare system. Design In this retrospective cross-sectional study of all patients in the U.S. Veterans Affairs (VA) Health Care System, we aggregated costs of individuals’ outpatient and inpatient care, pharmacy services and VA-sponsored contract care received in 2010. We assessed chronic condition prevalence, multimorbidity as measured by comorbidity count, and multisystem multimorbidity (number of body systems affected by chronic conditions) among the 5% highest cost patients. Using multivariate regression, we examined the association between multimorbidity and healthcare utilisation and costs, adjusting for age, sex, race/ethnicity, marital status, homelessness and health insurance status. Setting USA VA Health Care System. Participants 5.2 million VA patients. Measures Annual total costs; absolute and share of costs generated through outpatient, inpatient, pharmacy and VA-sponsored contract care; number of visits to primary, specialty and mental healthcare; number of emergency department visits and hospitalisations. Results The 5% highest cost patients (n=261 699) accounted for 47% of total VA costs. Approximately two-thirds of these patients had chronic conditions affecting ≥3 body systems. Patients with cancer and schizophrenia were less likely to have documented comorbid conditions than other high-cost patients. Multimorbidity was generally associated with greater outpatient and inpatient utilisation. However, increased multisystem multimorbidity was associated with a higher outpatient share of total costs (1.6 percentage points per affected body system, p<0.01) but a lower inpatient share of total costs (−0.6 percentage points per affected body system, p<0.01). Conclusions Multisystem multimorbidity is common among high-cost VA patients. While some patients might benefit from disease-specific programmes, for most patients with multimorbidity there is a need for interventions that coordinate and maximise efficiency of outpatient services across multiple conditions. PMID:25882486

  14. Predictors of mental health-related acute service utilisation and treatment costs in the 12 months following an acute psychiatric admission.

    PubMed

    Siskind, Dan; Harris, Meredith; Diminic, Sandra; Carstensen, Georgia; Robinson, Gail; Whiteford, Harvey

    2014-11-01

    A key step in informing mental health resource allocation is to identify the predictors of service utilisation and costs. This project aims to identify the predictors of mental health-related acute service utilisation and treatment costs in the year following an acute public psychiatric hospital admission. A dataset containing administrative and routinely measured outcome data for 1 year before and after an acute psychiatric admission for 1757 public mental health patients was analysed. Multivariate regression models were developed to identify patient- and treatment-related predictors of four measures of service utilisation or cost: (a) duration of index admission; and, in the year after discharge from the index admission (b) acute psychiatric inpatient bed-days; (c) emergency department (ED) presentations; and (d) total acute mental health service costs. Split-sample cross-validation was used. A diagnosis of psychosis, problems with living conditions and prior acute psychiatric inpatient bed-days predicted a longer duration of index admission, while prior ED presentations and self-harm predicted a shorter duration. A greater number of acute psychiatric inpatient bed-days in the year post-discharge were predicted by psychosis diagnosis, problems with living conditions and prior acute psychiatric inpatient admissions. The number of future ED presentations was predicted by past ED presentations. For total acute care costs, diagnosis of psychosis was the strongest predictor. Illness acuity and prior acute psychiatric inpatient admission also predicted higher costs, while self-harm predicted lower costs. The development of effective models for predicting acute mental health treatment costs using existing administrative data is an essential step towards a workable activity-based funding model for mental health. Future studies would benefit from the inclusion of a wider range of variables, including ethnicity, clinical complexity, cognition, mental health legal status, electroconvulsive therapy, problems with activities of daily living and community contacts. © The Royal Australian and New Zealand College of Psychiatrists 2014.

  15. A prospective randomised study to compare the utility and outcomes of subdural and subperiosteal drains for the treatment of chronic subdural haematoma.

    PubMed

    Kaliaperumal, Chandrasekaran; Khalil, Ayman; Fenton, Eoin; Okafo, Uchenna; Kaar, George; O'Sullivan, Michael; Marks, Charles

    2012-11-01

    The usage of a drain following evacuation of a chronic subdural haematoma (CSDH) is known to reduce recurrence. In this study we aim to compare the clinical outcomes and recurrence rate of utilising two different types of drains (subperiosteal and subdural drain) following drainage of a CSDH. Prospective randomised single-centre study analysing 50 patients who underwent CSDH treatment. Two types of drains, subperiosteal (SPD) and subdural (SDD), were utilised on consecutive alternate patients following burr-hole craniostomy, with a total of 25 patients in each group. The drains were left in for 48-h duration and then removed. The modified Rankin Scale (mRS) was used for outcome measurement at 3 and 6 months. Data analysis was performed by unpaired t test with Welch's correction. It was observed that none of the patients in either group had haematoma recurrence during a 6-month follow-up, and a significant difference in outcome was noted at 6 months (p = 0.0118) more than at 3 months (p = 0.0493) according to the statistical analysis. Postoperative seizure and inadvertent placement of the subdural drain into the brain parenchyma were the two complications noted in this study. Anticoagulant use prior to the surgery did not affect the outcome in either group. We conclude there was no recurrence of CSDH utilising the SDD and SPD following burr-hole craniostomy. The mRS measurement at the 6-month follow-up was found to be statistically significant, with better outcomes with utilisation of the SPD. The SPD may thus prove to be more beneficial than the SDD in the treatment of CSDH. A multi-centre study with a larger group of patients is recommended to reinforce the results from our study.

  16. Utilising the Intel RealSense Camera for Measuring Health Outcomes in Clinical Research.

    PubMed

    Siena, Francesco Luke; Byrom, Bill; Watts, Paul; Breedon, Philip

    2018-02-05

    Applications utilising 3D Camera technologies for the measurement of health outcomes in the health and wellness sector continues to expand. The Intel® RealSense™ is one of the leading 3D depth sensing cameras currently available on the market and aligns itself for use in many applications, including robotics, automation, and medical systems. One of the most prominent areas is the production of interactive solutions for rehabilitation which includes gait analysis and facial tracking. Advancements in depth camera technology has resulted in a noticeable increase in the integration of these technologies into portable platforms, suggesting significant future potential for pervasive in-clinic and field based health assessment solutions. This paper reviews the Intel RealSense technology's technical capabilities and discusses its application to clinical research and includes examples where the Intel RealSense camera range has been used for the measurement of health outcomes. This review supports the use of the technology to develop robust, objective movement and mobility-based endpoints to enable accurate tracking of the effects of treatment interventions in clinical trials.

  17. Incremental Impact of Time on Students' Use of E-Learning via Facebook

    ERIC Educational Resources Information Center

    Moghavvemi, Sedigheh; Salarzadeh Janatabadi, Hashem

    2018-01-01

    The majority of studies utilised the cross-sectional method to measure students' intention to learn and investigate their corresponding learning behaviours. Only a few studies have measured the process of change in students' learning behaviour in the context of time. The main purpose of this study is to determine the effects of using a Facebook…

  18. Measurement of labile copper in wine by medium exchange stripping potentiometry utilising screen printed carbon electrodes.

    PubMed

    Clark, Andrew C; Kontoudakis, Nikolaos; Barril, Celia; Schmidtke, Leigh M; Scollary, Geoffrey R

    2016-07-01

    The presence of copper in wine is known to impact the reductive, oxidative and colloidal stability of wine, and techniques enabling measurement of different forms of copper in wine are of particular interest in understanding these spoilage processes. Electrochemical stripping techniques developed to date require significant pretreatment of wine, potentially disturbing the copper binding equilibria. A thin mercury film on a screen printed carbon electrode was utilised in a flow system for the direct analysis of labile copper in red and white wine by constant current stripping potentiometry with medium exchange. Under the optimised conditions, including an enrichment time of 500s and constant current of 1.0μA, the response range was linear from 0.015 to 0.200mg/L. The analysis of 52 red and white wines showed that this technique generally provided lower labile copper concentrations than reported for batch measurement by related techniques. Studies in a model system and in finished wines showed that the copper sulfide was not measured as labile copper, and that loss of hydrogen sulfide via volatilisation induced an increase in labile copper within the model wine system. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. MO-E-BRD-01: Is Non-Invasive Image-Guided Breast Brachytherapy Good?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hiatt, J.

    2015-06-15

    Is Non-invasive Image-Guided Breast Brachytherapy Good? – Jess Hiatt, MS Non-invasive Image-Guided Breast Brachytherapy (NIBB) is an emerging therapy for breast boost treatments as well as Accelerated Partial Breast Irradiation (APBI) using HDR surface breast brachytherapy. NIBB allows for smaller treatment volumes while maintaining optimal target coverage. Considering the real-time image-guidance and immobilization provided by the NIBB modality, minimal margins around the target tissue are necessary. Accelerated Partial Breast Irradiation in brachytherapy: is shorter better? - Dorin Todor, PhD VCU A review of balloon and strut devices will be provided together with the origins of APBI: the interstitial multi-catheter implant.more » A dosimetric and radiobiological perspective will help point out the evolution in breast brachytherapy, both in terms of devices and the protocols/clinical trials under which these devices are used. Improvements in imaging, delivery modalities and convenience are among the factors driving the ultrashort fractionation schedules but our understanding of both local control and toxicities associated with various treatments is lagging. A comparison between various schedules, from a radiobiological perspective, will be given together with a critical analysis of the issues. to review and understand the evolution and development of APBI using brachytherapy methods to understand the basis and limitations of radio-biological ‘equivalence’ between fractionation schedules to review commonly used and proposed fractionation schedules Intra-operative breast brachytherapy: Is one stop shopping best?- Bruce Libby, PhD. University of Virginia A review of intraoperative breast brachytherapy will be presented, including the Targit-A and other trials that have used electronic brachytherapy. More modern approaches, in which the lumpectomy procedure is integrated into an APBI workflow, will also be discussed. Learning Objectives: To review past and current clinical trials for IORT To discuss lumpectomy-scan-plan-treat workflow for IORT.« less

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shin, J; Park, S; Jeong, J

    Purpose: In particle therapy and radiobiology, the investigation of mechanisms leading to the death of target cancer cells induced by ionising radiation is an active field of research. Recently, several studies based on Monte Carlo simulation codes have been initiated in order to simulate physical interactions of ionising particles at cellular scale and in DNA. Geant4-DNA is the one of them; it is an extension of the general purpose Geant4 Monte Carlo simulation toolkit for the simulation of physical interactions at sub-micrometre scale. In this study, we present Geant4-DNA Monte Carlo simulations for the prediction of DNA strand breakage usingmore » a geometrical modelling of DNA structure. Methods: For the simulation of DNA strand breakage, we developed a specific DNA geometrical structure. This structure consists of DNA components, such as the deoxynucleotide pairs, the DNA double helix, the nucleosomes and the chromatin fibre. Each component is made of water because the cross sections models currently available in Geant4-DNA for protons apply to liquid water only. Also, at the macroscopic-scale, protons were generated with various energies available for proton therapy at the National Cancer Center, obtained using validated proton beam simulations developed in previous studies. These multi-scale simulations were combined for the validation of Geant4-DNA in radiobiology. Results: In the double helix structure, the deposited energy in a strand allowed to determine direct DNA damage from physical interaction. In other words, the amount of dose and frequency of damage in microscopic geometries was related to direct radiobiological effect. Conclusion: In this report, we calculated the frequency of DNA strand breakage using Geant4- DNA physics processes for liquid water. This study is now on-going in order to develop geometries which use realistic DNA material, instead of liquid water. This will be tested as soon as cross sections for DNA material become available in Geant4-DNA.« less

  1. MO-E-BRD-03: Intra-Operative Breast Brachytherapy: Is One Stop Shopping Best? [Non-invasive Image-Guided Breast Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Libby, B.

    2015-06-15

    Is Non-invasive Image-Guided Breast Brachytherapy Good? – Jess Hiatt, MS Non-invasive Image-Guided Breast Brachytherapy (NIBB) is an emerging therapy for breast boost treatments as well as Accelerated Partial Breast Irradiation (APBI) using HDR surface breast brachytherapy. NIBB allows for smaller treatment volumes while maintaining optimal target coverage. Considering the real-time image-guidance and immobilization provided by the NIBB modality, minimal margins around the target tissue are necessary. Accelerated Partial Breast Irradiation in brachytherapy: is shorter better? - Dorin Todor, PhD VCU A review of balloon and strut devices will be provided together with the origins of APBI: the interstitial multi-catheter implant.more » A dosimetric and radiobiological perspective will help point out the evolution in breast brachytherapy, both in terms of devices and the protocols/clinical trials under which these devices are used. Improvements in imaging, delivery modalities and convenience are among the factors driving the ultrashort fractionation schedules but our understanding of both local control and toxicities associated with various treatments is lagging. A comparison between various schedules, from a radiobiological perspective, will be given together with a critical analysis of the issues. to review and understand the evolution and development of APBI using brachytherapy methods to understand the basis and limitations of radio-biological ‘equivalence’ between fractionation schedules to review commonly used and proposed fractionation schedules Intra-operative breast brachytherapy: Is one stop shopping best?- Bruce Libby, PhD. University of Virginia A review of intraoperative breast brachytherapy will be presented, including the Targit-A and other trials that have used electronic brachytherapy. More modern approaches, in which the lumpectomy procedure is integrated into an APBI workflow, will also be discussed. Learning Objectives: To review past and current clinical trials for IORT To discuss lumpectomy-scan-plan-treat workflow for IORT.« less

  2. TH-E-BRF-06: Kinetic Modeling of Tumor Response to Fractionated Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhong, H; Gordon, J; Chetty, I

    2014-06-15

    Purpose: Accurate calibration of radiobiological parameters is crucial to predicting radiation treatment response. Modeling differences may have a significant impact on calibrated parameters. In this study, we have integrated two existing models with kinetic differential equations to formulate a new tumor regression model for calibrating radiobiological parameters for individual patients. Methods: A system of differential equations that characterizes the birth-and-death process of tumor cells in radiation treatment was analytically solved. The solution of this system was used to construct an iterative model (Z-model). The model consists of three parameters: tumor doubling time Td, half-life of dying cells Tr and cellmore » survival fraction SFD under dose D. The Jacobian determinant of this model was proposed as a constraint to optimize the three parameters for six head and neck cancer patients. The derived parameters were compared with those generated from the two existing models, Chvetsov model (C-model) and Lim model (L-model). The C-model and L-model were optimized with the parameter Td fixed. Results: With the Jacobian-constrained Z-model, the mean of the optimized cell survival fractions is 0.43±0.08, and the half-life of dying cells averaged over the six patients is 17.5±3.2 days. The parameters Tr and SFD optimized with the Z-model differ by 1.2% and 20.3% from those optimized with the Td-fixed C-model, and by 32.1% and 112.3% from those optimized with the Td-fixed L-model, respectively. Conclusion: The Z-model was analytically constructed from the cellpopulation differential equations to describe changes in the number of different tumor cells during the course of fractionated radiation treatment. The Jacobian constraints were proposed to optimize the three radiobiological parameters. The developed modeling and optimization methods may help develop high-quality treatment regimens for individual patients.« less

  3. MO-E-BRD-02: Accelerated Partial Breast Irradiation in Brachytherapy: Is Shorter Better?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Todor, D.

    2015-06-15

    Is Non-invasive Image-Guided Breast Brachytherapy Good? – Jess Hiatt, MS Non-invasive Image-Guided Breast Brachytherapy (NIBB) is an emerging therapy for breast boost treatments as well as Accelerated Partial Breast Irradiation (APBI) using HDR surface breast brachytherapy. NIBB allows for smaller treatment volumes while maintaining optimal target coverage. Considering the real-time image-guidance and immobilization provided by the NIBB modality, minimal margins around the target tissue are necessary. Accelerated Partial Breast Irradiation in brachytherapy: is shorter better? - Dorin Todor, PhD VCU A review of balloon and strut devices will be provided together with the origins of APBI: the interstitial multi-catheter implant.more » A dosimetric and radiobiological perspective will help point out the evolution in breast brachytherapy, both in terms of devices and the protocols/clinical trials under which these devices are used. Improvements in imaging, delivery modalities and convenience are among the factors driving the ultrashort fractionation schedules but our understanding of both local control and toxicities associated with various treatments is lagging. A comparison between various schedules, from a radiobiological perspective, will be given together with a critical analysis of the issues. to review and understand the evolution and development of APBI using brachytherapy methods to understand the basis and limitations of radio-biological ‘equivalence’ between fractionation schedules to review commonly used and proposed fractionation schedules Intra-operative breast brachytherapy: Is one stop shopping best?- Bruce Libby, PhD. University of Virginia A review of intraoperative breast brachytherapy will be presented, including the Targit-A and other trials that have used electronic brachytherapy. More modern approaches, in which the lumpectomy procedure is integrated into an APBI workflow, will also be discussed. Learning Objectives: To review past and current clinical trials for IORT To discuss lumpectomy-scan-plan-treat workflow for IORT.« less

  4. Tumor Control Probability Modeling for Stereotactic Body Radiation Therapy of Early-Stage Lung Cancer Using Multiple Bio-physical Models

    PubMed Central

    Liu, Feng; Tai, An; Lee, Percy; Biswas, Tithi; Ding, George X.; El Naqa, Isaam; Grimm, Jimm; Jackson, Andrew; Kong, Feng-Ming (Spring); LaCouture, Tamara; Loo, Billy; Miften, Moyed; Solberg, Timothy; Li, X Allen

    2017-01-01

    Purpose To analyze pooled clinical data using different radiobiological models and to understand the relationship between biologically effective dose (BED) and tumor control probability (TCP) for stereotactic body radiotherapy (SBRT) of early-stage non-small cell lung cancer (NSCLC). Method and Materials The clinical data of 1-, 2-, 3-, and 5-year actuarial or Kaplan-Meier TCP from 46 selected studies were collected for SBRT of NSCLC in the literature. The TCP data were separated for Stage T1 and T2 tumors if possible, otherwise collected for combined stages. BED was calculated at isocenters using six radiobiological models. For each model, the independent model parameters were determined from a fit to the TCP data using the least chi-square (χ2) method with either one set of parameters regardless of tumor stages or two sets for T1 and T2 tumors separately. Results The fits to the clinic data yield consistent results of large α/β ratios of about 20 Gy for all models investigated. The regrowth model that accounts for the tumor repopulation and heterogeneity leads to a better fit to the data, compared to other 5 models where the fits were indistinguishable between the models. The models based on the fitting parameters predict that the T2 tumors require about additional 1 Gy physical dose at isocenters per fraction (≤5 fractions) to achieve the optimal TCP when compared to the T1 tumors. Conclusion This systematic analysis of a large set of published clinical data using different radiobiological models shows that local TCP for SBRT of early-stage NSCLC has strong dependence on BED with large α/β ratios of about 20 Gy. The six models predict that a BED (calculated with α/β of 20) of 90 Gy is sufficient to achieve TCP ≥ 95%. Among the models considered, the regrowth model leads to a better fit to the clinical data. PMID:27871671

  5. SU-E-T-275: Radiobiological Evaluation of Intensity Modulated Radiotherapy Treatment for Locally Advanced Head and Neck Squamous Cell Carcinomas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rekha Reddy, B.; Ravikumar, M.; Tanvir Pasha, C.R

    2014-06-01

    Purpose: To evaluate the radiobiological outcome of Intensity Modulated Radiotherapy Treatment (IMRT) for locally advanced head and neck squamous cell carcinomas using HART (Histogram Analysis in Radiation Therapy; J Appl Clin Med Phys 11(1): 137–157, 2010) program and compare with the clinical outcomes. Methods: We have treated 20 patients of stage III and IV HNSCC Oropharynx and hypopharynx with accelerated IMRT technique and concurrent chemotherapy. Delineation of tumor and normal tissues were done using Danish Head and Neck Cancer Group (DAHANCA) contouring guidelines and radiotherapy was delivered to a dose of 70Gy in 35 fractions to the primary and involvedmore » lymph nodes, 63Gy to intermediate risk areas and 56 Gy to lower risk areas, Monday to Saturday, 6 Days/week using 6 MV Photons with an expected overall treatment time of 6 weeks. The TCP and NTCP's were calculated from the dose-volume histogram (DVH) statistics using the Poisson Statistics (PS) and JT Lyman models respectively and the Resultwas correlated with clinical outcomes of the patients with mean follow up of 24 months. Results: Using HART program, the TCP (0.89± 0.01) of primary tumor and the NTCP for parotids (0.20±0.12), spinal cord (0.05±0.01), esophagus (0.30±0.2), mandible (0.35±0.21), Oral cavity (0.37±0.18), Larynx (0.30±0.15) were estimated and correlated with clinical outcome of the patients. Conclusion: Accelerated IMRT with Chemotherapy is a clinical feasible option in the treatment of locally advanced HNSCC with encouraging initial tumour response and acceptable acute toxicities. The correlation between the clinical outcomes and radiobiological model estimated parameters using HART programs are found to be satisfactory.« less

  6. Dosimetric and radiobiological characterizations of prostate intensity-modulated radiotherapy and volumetric-modulated arc therapy: A single-institution review of ninety cases

    PubMed Central

    Khan, Muhammad Isa; Jiang, Runqing; Kiciak, Alexander; ur Rehman, Jalil; Afzal, Muhammad; Chow, James C. L.

    2016-01-01

    This study reviewed prostate volumetric-modulated arc therapy (VMAT) plans with intensity-modulated radiotherapy (IMRT) plans after prostate IMRT technique was replaced by VMAT in an institution. Characterizations of dosimetry and radiobiological variation in prostate were determined based on treatment plans of 40 prostate IMRT patients (planning target volume = 77.8–335 cm3) and 50 VMAT patients (planning target volume = 120–351 cm3) treated before and after 2013, respectively. Both IMRT and VMAT plans used the same dose-volume criteria in the inverse planning optimization. Dose-volume histogram, mean doses of target and normal tissues (rectum, bladder and femoral heads), dose-volume points (D99% of planning target volume; D30%, D50%, V30 Gy and V35 Gy of rectum and bladder; D5%, V14 Gy, V22 Gy of femoral heads), conformity index (CI), homogeneity index (HI), gradient index (GI), prostate tumor control probability (TCP), and rectal normal tissue complication probability (NTCP) based on the Lyman-Burman-Kutcher algorithm were calculated for each IMRT and VMAT plan. From our results, VMAT plan was found better due to its higher (1.05%) CI, lower (0.83%) HI and (0.75%) GI than IMRT. Comparing doses in normal tissues between IMRT and VMAT, it was found that IMRT mostly delivered higher doses of about 1.05% to the normal tissues than VMAT. Prostate TCP and rectal NTCP were found increased (1%) for VMAT than IMRT. It is seen that VMAT technique can decrease the dose-volume evaluation criteria for the normal tissues. Based on our dosimetric and radiobiological results in treatment plans, it is concluded that our VMAT implementation could produce comparable or slightly better target coverage and normal tissue sparing with a faster treatment time in prostate radiotherapy. PMID:27651562

  7. Digital Learning Resources and Ubiquitous Technologies in Education

    ERIC Educational Resources Information Center

    Camilleri, Mark Anthony; Camilleri, Adriana Caterina

    2017-01-01

    This research explores the educators' attitudes and perceptions about their utilisation of digital learning technologies. The methodology integrates measures from "the pace of technological innovativeness" and the "technology acceptance model" to understand the rationale for further ICT investment in compulsory education. A…

  8. Forensic analysis of explosives using isotope ratio mass spectrometry (IRMS)--preliminary study on TATP and PETN.

    PubMed

    Benson, Sarah J; Lennard, Christopher J; Maynard, Philip; Hill, David M; Andrew, Anita S; Roux, Claude

    2009-06-01

    The application of isotopic techniques to investigations requiring the provision of evidence to a Court is limited. The objective of this research was to investigate the application of light stable isotopes and isotope ratio mass spectrometry (IRMS) to solve complex forensic cases by providing a level of discrimination not achievable utilising traditional forensic techniques. Due to the current threat of organic peroxide explosives, such as triacetone triperoxide (TATP), research was undertaken to determine the potential of IRMS to differentiate samples of TATP that had been manufactured utilising different starting materials and/or manufacturing processes. In addition, due to the prevalence of pentaerythritoltetranitrate (PETN) in detonators, detonating cord, and boosters, the potential of the IRMS technique to differentiate PETN samples from different sources was also investigated. Carbon isotope values were measured in fourteen TATP samples, with three definite groups appearing in the initial sample set based on the carbon data alone. Four additional TATP samples (in a second set of samples) were distinguishable utilising the carbon and hydrogen isotopic compositions individually, and also in combination with the oxygen isotope values. The 3D plot of the carbon, oxygen and hydrogen data demonstrated the clear discrimination of the four samples of TATP. The carbon and nitrogen isotope values measured from fifteen PETN samples, allowed samples from different sources to be readily discriminated. This paper demonstrates the successful application of IRMS to the analysis of explosives of forensic interest to assist in discriminating samples from different sources. This research represents a preliminary evaluation of the IRMS technique for the measurement of stable isotope values in TATP and PETN samples, and supports the dedication of resources for a full evaluation of this application in order to achieve Court reportable IRMS results.

  9. Ti : sapphire laser synchronised with femtosecond Yb pump laser via nonlinear pulse coupling in Ti : sapphire active medium

    NASA Astrophysics Data System (ADS)

    Didenko, N. V.; Konyashchenko, A. V.; Konyashchenko, D. A.; Kostryukov, P. V.; Kuritsyn, I. I.; Lutsenko, A. P.; Mavritskiy, A. O.

    2017-02-01

    A laser system utilising the method of synchronous pumping of a Ti : sapphire laser by a high-power femtosecond Yb3+-doped laser is described. The pulse repetition rate of the Ti : sapphire laser is successfully locked to the repetition rate of the Yb laser for more than 6 hours without the use of any additional electronics. The measured timing jitter is shown to be less than 1 fs. A simple qualitative model addressing the synchronisation mechanism utilising the cross-phase modulation of oscillation and pump pulses within a Ti : sapphire active medium is proposed. Output parameters of the Ti : sapphire laser as functions of its cavity length are discussed in terms of this model.

  10. The impact of user fees on access to health services in low- and middle-income countries.

    PubMed

    Lagarde, Mylene; Palmer, Natasha

    2011-04-13

    Following an international push for financing reforms, many low- and middle-income countries introduced user fees to raise additional revenue for health systems. User fees are charges levied at the point of use and are supposed to help reduce 'frivolous' consumption of health services, increase quality of services available and, as a result, increase utilisation of services. To assess the effectiveness of introducing, removing or changing user fees to improve access to care in low-and middle-income countries We searched 25 international databases, including the Cochrane Effective Practice and Organisation of Care (EPOC) Group's Trials Register, CENTRAL, MEDLINE and EMBASE. We also searched the websites and online resources of international agencies, organisations and universities to find relevant grey literature. We conducted the original searches between November 2005 and April 2006 and the updated search in CENTRAL (DVD-ROM 2011, Issue 1); MEDLINE In-Process & Other Non-Indexed Citations, Ovid (January 25, 2011); MEDLINE, Ovid (1948 to January Week 2 2011); EMBASE, Ovid (1980 to 2011 Week 03) and EconLit, CSA Illumina (1969 - present) on the 26th of January 2011. We included randomised controlled trials, interrupted time-series studies and controlled before-and-after studies that reported an objective measure of at least one of the following outcomes: healthcare utilisation, health expenditures, or health outcomes. We re-analysed studies with longitudinal data. We computed price elasticities of demand for health services in controlled before-and-after studies as a standardised measure. Due to the diversity of contexts and outcome measures, we did not perform meta-analysis. Instead, we undertook a narrative summary of evidence. We included 16 studies out of the 243 identified. Most of the included studies showed methodological weaknesses that hamper the strength and reliability of their findings. When fees were introduced or increased, we found the use of health services decreased significantly in most studies. Two studies found increases in health service use when quality improvements were introduced at the same time as user fees. However, these studies have a high risk of bias. We found no evidence of effects on health outcomes or health expenditure. The review suggests that reducing or removing user fees increases the utilisation of certain healthcare services. However, emerging evidence suggests that such a change may have unintended consequences on utilisation of preventive services and service quality. The review also found that introducing or increasing fees can have a negative impact on health services utilisation, although some evidence suggests that when implemented with quality improvements these interventions could be beneficial. Most of the included studies suffered from important methodological weaknesses. More rigorous research is needed to inform debates on the desirability and effects of user fees.

  11. Floodwater utilisation values of wetland services - a case study in Northeastern China

    NASA Astrophysics Data System (ADS)

    Lü, S. B.; Xu, S. G.; Feng, F.

    2012-02-01

    Water plays a significant role in wetlands. Floodwater utilisation in wetlands brings a wide range of wetland services, from goods production and water regulation to animal protection and aesthetics related to water supply in wetlands. In this study, the floodwater utilisation values of wetland services were estimated within the Momoge wetland and Xianghai wetland in western Jilin province of northeastern China. From 2003 to 2008, the floodwater diverted from the Nenjiang and Tao'er River is 381 million m3, which translates into a monetary value of approximately 1.35 billion RMB in 2008 (RMB: Chinese Currency, RMB 6.80 = US 1), and the ratio of economic value, eco-environmental value, and social value is 1:12:2. Besides the monetary value of the water itself, excessive floodwater utilisation may bring losses to wetlands; the threshold floodwater utilisation volumes in wetlands are discussed. Floodwater utilisation can alleviate water shortages in wetlands, and the evaluation of floodwater utilisation in wetland services in monetary terms is a guide for the effective use of the floodwater resources and for the conservation of wetlands.

  12. Differences in carbon source utilisation by orchid mycorrhizal fungi from common and endangered species of Caladenia (Orchidaceae).

    PubMed

    Mehra, S; Morrison, P D; Coates, F; Lawrie, A C

    2017-02-01

    Terrestrial orchids depend on orchid mycorrhizal fungi (OMF) as symbionts for their survival, growth and nutrition. The ability of OMF from endangered orchid species to compete for available resources with OMF from common species may affect the distribution, abundance and therefore conservation status of their orchid hosts. Eight symbiotically effective OMF from endangered and more common Caladenia species were tested for their ability to utilise complex insoluble and simple soluble carbon sources produced during litter degradation by growth with different carbon sources in liquid medium to measure the degree of OMF variation with host conservation status or taxonomy. On simple carbon sources, fungal growth was assessed by biomass. On insoluble substrates, ergosterol content was assessed using ultra-performance liquid chromatography (UPLC). The OMF grew on all natural materials and complex carbon sources, but produced the greatest biomass on xylan and starch and the least on bark and chitin. On simple carbon sources, the greatest OMF biomass was measured on most hexoses and disaccharides and the least on galactose and arabinose. Only some OMF used sucrose, the most common sugar in green plants, with possible implications for symbiosis. OMF from common orchids produced more ergosterol and biomass than those from endangered orchids in the Dilatata and Reticulata groups but not in the Patersonii and Finger orchids. This suggests that differences in carbon source utilisation may contribute to differences in the distribution of some orchids, if these differences are retained on site.

  13. Comparison of measurement methods for capacitive tactile sensors and their implementation

    NASA Astrophysics Data System (ADS)

    Tarapata, Grzegorz; Sienkiewicz, Rafał

    2015-09-01

    This paper presents a review of ideas and implementations of measurement methods utilized for capacity measurements in tactile sensors. The paper describes technical method, charge amplification method, generation and as well integration method. Three selected methods were implemented in dedicated measurement system and utilised for capacitance measurements of ourselves made tactile sensors. The tactile sensors tested in this work were fully fabricated with the inkjet printing technology. The tests result were presented and summarised. The charge amplification method (CDC) was selected as the best method for the measurement of the tactile sensors.

  14. Hospital admissions for severe mental illness in England: changes in equity of utilisation at the small area level between 2006 and 2010.

    PubMed

    White, Jonathan; Gutacker, Nils; Jacobs, Rowena; Mason, Anne

    2014-11-01

    Severe Mental Illness (SMI) encompasses a range of chronic conditions including schizophrenia, bipolar disorder and psychoses. Patients with SMI often require inpatient psychiatric care. Despite equity being a key objective in the English National Health Service (NHS) and in many other health care systems worldwide, little is known about the socio-economic equity of hospital care utilisation for patients with SMI and how it has changed over time. This analysis seeks to address that gap in the evidence base. We exploit a five-year (2006-2010) panel dataset of admission rates at small area level (n=162,410). The choice of control variables was informed by a systematic literature search. To assess changes in socio-economic equity of utilisation, OLS-based standardisation was first used to conduct analysis of discrete deprivation groups. Geographical inequity was then illustrated by plotting standardised and crude admission rates at local purchaser level. Lastly, formal statistical tests for changes in socio-economic equity of utilisation were applied to a continuous measure of deprivation using pooled negative binomial regression analysis, adjusting for a range of risk factors. Our results suggest that one additional percentage point of area income deprivation is associated with a 1.5% (p<0.001) increase in admissions for SMI after controlling for population size, age, sex, prevalence of SMI in the local population, as well as other need and supply factors. This finding is robust to sensitivity analyses, suggesting that a pro-poor inequality in utilisation exists for SMI-related inpatient services. One possible explanation is that the supply or quality of primary, community or social care for people with mental health problems is suboptimal in deprived areas. Although there is some evidence that inequity has reduced over time, the changes are small and not always robust to sensitivity analyses. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  15. A long way to go: a systematic review to assess the utilisation of sexual and reproductive health services during humanitarian crises.

    PubMed

    Singh, Neha S; Aryasinghe, Sarindi; Smith, James; Khosla, Rajat; Say, Lale; Blanchet, Karl

    2018-01-01

    Women and girls are affected significantly in both sudden and slow-onset emergencies, and face multiple sexual and reproductive health (SRH) challenges in humanitarian crises contexts. There are an estimated 26 million women and girls of reproductive age living in humanitarian crises settings, all of whom need access to SRH information and services. This systematic review aimed to assess the utilisation of services of SRH interventions from the onset of emergencies in low- and middle-income countries. We searched for both quantitative and qualitative studies in peer-reviewed journals across the following four databases: EMBASE, Global Health, MEDLINE and PsychINFO from 1 January 1980 to 10 April 2017. Primary outcomes of interest included self-reported use and/or confirmed use of the Minimum Initial Service Package services and abortion services. Two authors independently extracted and analysed data from published papers on the effect of SRH interventions on a range of SRH care utilisation outcomes from the onset of emergencies, and used a narrative synthesis approach. Of the 2404 identified citations, 23 studies met the inclusion criteria. 52.1% of the studies (n=12) used quasi-experimental study designs, which provided some statistical measure of difference between intervention and outcome. 39.1% of the studies (n=9) selected were graded as high quality, 39.1% moderate quality (n=9) and 17.4% low quality (n=4). Evidence of effectiveness in increasing service utilisation was available for the following interventions: peer-led and interpersonal education and mass media campaigns, community-based programming and three-tiered network of community-based reproductive and maternal health providers. Despite increased attention to SRH service provision in humanitarian crises settings, the evidence base is still very limited. More implementation research is required to identify interventions to increase utilisation of SRH services in diverse humanitarian crises settings and populations.

  16. Low utilisation of diabetes medicines in Iran, despite their affordability (2000-2012): a time-series and benchmarking study.

    PubMed

    Sarayani, Amir; Rashidian, Arash; Gholami, Kheirollah

    2014-10-16

    Diabetes is a major public health concern worldwide, particularly in low-income and middle-income countries (LMICs). Limited data exist on the status of access to diabetes medicines in LMICs. We assessed the utilisation and affordability of diabetes medicines in Iran as a middle-income country. We used a retrospective time-series design (2000-2012) and assessed national diabetes medicines' utilisation using pharmaceuticals wholesale data. We calculated defined daily dose consumptions per population days (DDDs/1000 inhabitants/day; DIDs) indicator. Findings were benchmarked with data from Organization for Economic Co-operation and Development (OECD) countries. We also employed Drug Utilization-90% (DU-90) method to compare DU-90s with the Essential Medicines List published by the WHO. We measured affordability using number of minimum daily wage required to purchase a treatment course for 1 month. Diabetes medicines' consumption increased from 4.47 to 33.54 DIDs. The benchmarking showed that medicines' utilisation in Iran in 2011 was only 54% of the median DIDs of 22 OECD countries. Oral hypoglycaemic agents consisted over 80% of use throughout the study period. Regular and isophane insulin (NPH), glibenclamide, metformin and gliclazide were the DU-90 drugs in 2012. Metformin, glibenclamide and regular/NPH insulin combination therapy were affordable throughout the study period (∼0.4, ∼0.1, ∼0.3 of minimum daily wage, respectively). While the affordability of novel insulin preparations improved over time, they were still unaffordable in 2012. The utilisation of diabetes medicines was relatively low, perhaps due to underdiagnosis and inadequate management of patients with diabetes. This had occurred despite affordability of essential diabetes medicines in Iran. Appropriate policies are required to address the underutilisation of diabetes medicines in Iran. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  17. A long way to go: a systematic review to assess the utilisation of sexual and reproductive health services during humanitarian crises

    PubMed Central

    Aryasinghe, Sarindi; Smith, James; Khosla, Rajat; Say, Lale; Blanchet, Karl

    2018-01-01

    Introduction Women and girls are affected significantly in both sudden and slow-onset emergencies, and face multiple sexual and reproductive health (SRH) challenges in humanitarian crises contexts. There are an estimated 26 million women and girls of reproductive age living in humanitarian crises settings, all of whom need access to SRH information and services. This systematic review aimed to assess the utilisation of services of SRH interventions from the onset of emergencies in low- and middle-income countries. Methods We searched for both quantitative and qualitative studies in peer-reviewed journals across the following four databases: EMBASE, Global Health, MEDLINE and PsychINFO from 1 January 1980 to 10 April 2017. Primary outcomes of interest included self-reported use and/or confirmed use of the Minimum Initial Service Package services and abortion services. Two authors independently extracted and analysed data from published papers on the effect of SRH interventions on a range of SRH care utilisation outcomes from the onset of emergencies, and used a narrative synthesis approach. Results Of the 2404 identified citations, 23 studies met the inclusion criteria. 52.1% of the studies (n=12) used quasi-experimental study designs, which provided some statistical measure of difference between intervention and outcome. 39.1% of the studies (n=9) selected were graded as high quality, 39.1% moderate quality (n=9) and 17.4% low quality (n=4). Evidence of effectiveness in increasing service utilisation was available for the following interventions: peer-led and interpersonal education and mass media campaigns, community-based programming and three-tiered network of community-based reproductive and maternal health providers. Conclusions Despite increased attention to SRH service provision in humanitarian crises settings, the evidence base is still very limited. More implementation research is required to identify interventions to increase utilisation of SRH services in diverse humanitarian crises settings and populations. PMID:29736272

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, J.F.

    Research in the biomedical sciences at PNL is described. Activities reported include: inhaled plutonium in dogs; national radiobiology archives; statistical analysis of data from animal studies; genotoxicity of inhaled energy effluents; molecular events during tumor initiation; biochemistry of free radical induced DNA damage; radon hazards in homes; mechanisms of radon injury; genetics of radon induced lung cancer; and in vivo/in vitro radon induced cellular damage.

  19. "Experimental Оncology" is the Best Scientific Journal in Ukraine according to SCOPUS!

    PubMed

    2016-06-01

    International scientific journal "Experimental Оncology" (Publishing House "MORION LLC", Kyiv, Ukraine - R.E. Kavetsky Institute of Experimental Pathology, Oncology and Radiobiology of the NAS of Ukraine, Kyiv, Ukraine) earned high global recognition, receiving the prestigious international award "SCOPUS Awards Ukraine" as a winner in the category "The Best Journal".

  20. AFRRI (Armed Forces Radiobiology Research Institute) Reports, October-December 1989

    DTIC Science & Technology

    1989-02-01

    lack receptors for rhGM-CSF [16]. t.:is timu- (201. In contrast. Antman et al. reported that in patients with lation is likely to be mediated through...O*Hara PJ. Berkner K. Segal GM. Hagen FS. 22. Antman KS. Griffin JD. Elias A. Socinski M1A. Ryan L, Can- Adamson 1W 11986) Genomic cloning

  1. Fundamentals of Radiation Physics

    DTIC Science & Technology

    2008-07-01

    Sources of Ionizing Radiation Electrically generated • Charged particle accelerators • Van de Graaff generator , cyclotron linear accelerator ...Presented at the Armed Forces Radiobiology Research Institute Scientific Medical Effects of Ionizing Radiation Course July 28 through August 1, 2008...conducted once a year, focuses on the latest research about the medical effects of ionizing radiation to help clinicians, health physicists, and

  2. Does charging different user fees for primary and secondary care affect first-contacts with primary healthcare? A systematic review

    PubMed Central

    Hone, Thomas; Lee, John Tayu; Majeed, Azeem; Conteh, Lesong; Millett, Christopher

    2017-01-01

    Abstract Policy-makers are increasingly considering charging users different fees between primary and secondary care (differential user charges) to encourage utilisation of primary health care in health systems with limited gate keeping. A systematic review was conducted to evaluate the impact of introducing differential user charges on service utilisation. We reviewed studies published in MEDLINE, EMBASE, the Cochrane library, EconLIT, HMIC, and WHO library databases from January 1990 until June 2015. We extracted data from the studies meeting defined eligibility criteria and assessed study quality using an established checklist. We synthesized evidence narratively. Eight studies from six countries met our eligibility criteria. The overall study quality was low, with diversity in populations, interventions, settings, and methods. Five studies examined the introduction of or increase in user charges for secondary care, with four showing decreased secondary care utilisation, and three showing increased primary care utilisation. One study identified an increase in primary care utilisation after primary care user charges were reduced. The introduction of a non-referral charge in secondary care was associated with lower primary care utilisation in one study. One study compared user charges across insurance plans, associating higher charges in secondary care with higher utilisation in both primary and secondary care. Overall, the impact of introducing differential user-charges on primary care utilisation remains uncertain. Further research is required to understand their impact as a demand side intervention, including implications for health system costs and on utilisation among low-income patients. PMID:28453713

  3. The utilisation of health research in policy-making: concepts, examples and methods of assessment

    PubMed Central

    Hanney, Stephen R; Gonzalez-Block, Miguel A; Buxton, Martin J; Kogan, Maurice

    2003-01-01

    The importance of health research utilisation in policy-making, and of understanding the mechanisms involved, is increasingly recognised. Recent reports calling for more resources to improve health in developing countries, and global pressures for accountability, draw greater attention to research-informed policy-making. Key utilisation issues have been described for at least twenty years, but the growing focus on health research systems creates additional dimensions. The utilisation of health research in policy-making should contribute to policies that may eventually lead to desired outcomes, including health gains. In this article, exploration of these issues is combined with a review of various forms of policy-making. When this is linked to analysis of different types of health research, it assists in building a comprehensive account of the diverse meanings of research utilisation. Previous studies report methods and conceptual frameworks that have been applied, if with varying degrees of success, to record utilisation in policy-making. These studies reveal various examples of research impact within a general picture of underutilisation. Factors potentially enhancing utilisation can be identified by exploration of: priority setting; activities of the health research system at the interface between research and policy-making; and the role of the recipients, or 'receptors', of health research. An interfaces and receptors model provides a framework for analysis. Recommendations about possible methods for assessing health research utilisation follow identification of the purposes of such assessments. Our conclusion is that research utilisation can be better understood, and enhanced, by developing assessment methods informed by conceptual analysis and review of previous studies. PMID:12646071

  4. Absolute cross sections for electronic excitation of condensed tetrahydrofuran (THF) by 11-16 eV electrons.

    PubMed

    Lemelin, V; Bass, A D; Cloutier, P; Sanche, L

    2016-11-07

    Absolute cross section (CS) data on the interaction of low energy electrons with DNA and its molecular constituents are required as input parameters in Monte-Carlo type simulations, for several radiobiological applications. Previously [V. Lemelin et al., J. Chem. Phys. 144, 074701 (2016)], we measured absolute vibrational CSs for low-energy electron scattering from condensed tetrahydrofuran, a convenient surrogate for the deoxyribose. Here we report absolute electronic CSs for energy losses of between 6 and 11.5 eV, by electrons with energies between 11 and 16 eV. The variation of these CSs with incident electron energy shows no evidence of transient anion states, consistent with theoretical and other experimental results, indicating that initial electron capture leading to DNA strand breaks occurs primarily on DNA bases or the phosphate group.

  5. Activation of microcarrier-attached lymphocytes in microgravity

    NASA Technical Reports Server (NTRS)

    Bechler, B.; Cogoli, A.; Cogoli-Greuter, M.; Muller, O.; Hunzinger, E.; Criswell, S. B.

    1992-01-01

    A technology has been developed to achieve optimal attachment of adhesion-independent lymphocytes to microcarrier beads. The activation of T-lymphocytes by concanavalin A was tested under microgravity conditions in an experiment carried out in space during the first Spacelab Life Science Mission. Activation, measured as the synthesis of deoxyribonucleic acid (DNA) and the production of interferon-gamma, more than doubled in attached lymphocytes in microgravity. The depression of the activation discovered in previous space experiments is due to an impairment not of the lymphocyte but of the macrophage function. The system described here may be useful for radiobiological investigations on the effect of high-energy particles and for testing the efficiency of the immune system in humans during the long-duration space flight planned in the future. The biotechnological significance of the increased lymphokine production in space remains to be assessed.

  6. Factors affecting Japanese retirees' healthcare service utilisation in Malaysia: a qualitative study

    PubMed Central

    Kohno, Ayako; Nik Farid, Nik Daliana; Musa, Ghazali; Abdul Aziz, Norlaili; Nakayama, Takeo; Dahlui, Maznah

    2016-01-01

    Objective While living overseas in another culture, retirees need to adapt to a new environment but often this causes difficulties, particularly among those elderly who require healthcare services. This study examines factors affecting healthcare service utilisation among Japanese retirees in Malaysia. Design We conducted 6 focus group discussions with Japanese retirees and interviewed 8 relevant medical services providers in-depth. Guided by the Andersen Healthcare Utilisation Model, we managed and analysed the data, using QSR NVivo 10 software and the directed content analysis method. Setting We interviewed participants at Japan Clubs and their offices. Participants 30 Japanese retirees who live in Kuala Lumpur and Ipoh, and 8 medical services providers. Results We identified health beliefs, medical symptoms and health insurance as the 3 most important themes, respectively, representing the 3 dimensions within the Andersen Healthcare Utilisation Model. Additionally, language barriers, voluntary health repatriation to Japan and psychological support were unique themes that influence healthcare service utilisation among Japanese retirees. Conclusions The healthcare service utilisation among Japanese retirees in Malaysia could be partially explained by the Andersen Healthcare Utilisation Model, together with some factors that were unique findings to this study. Healthcare service utilisation among Japanese retirees in Malaysia could be improved by alleviating negative health beliefs through awareness programmes for Japanese retirees about the healthcare systems and cultural aspects of medical care in Malaysia. PMID:27006344

  7. Heating Has No Effect on the Net Protein Utilisation from Egg Whites in Rats

    PubMed Central

    Takahashi, Yayoi; Kimura, Mamoru; Masuda, Yasunobu; Kunou, Masaaki

    2017-01-01

    Egg whites (EW) are a good source of protein; however, they are typically heated prior to consumption. Therefore, we investigated the effects of different heating conditions on the protein utilisation rate of EW. Male Sprague-Dawley rats (n = 36, 198 ± 1 g) were divided into six groups and fed American Institute of Nutrition-76 chow containing unheated EW, soft-boiled EW, boiled EW, milk whey protein, soybean protein, or no protein over a 10-day period using pair-feeding. Urine and faeces were sampled daily beginning on day 5 to measure nitrogen content and the net protein utilisation (NPU) rate. The soybean protein group had a significantly lower level of food intake and was thus excluded from subsequent analyses. The NPU value was similar among the unheated, soft-boiled, and boiled EW groups (97.5 ± 0.4, 96.5 ± 0.1, and 96.5 ± 0.7, resp.). The EW group values were significantly higher than the whey group values (90.5 ± 1.0). These results show that EW serve as a good source of protein, irrespective of heating. PMID:28337477

  8. Monitoring biodegradation of diesel fuel in bioventing processes using in situ respiration rate.

    PubMed

    Lee, T H; Byun, I G; Kim, Y O; Hwang, I S; Park, T J

    2006-01-01

    An in situ measuring system of respiration rate was applied for monitoring biodegradation of diesel fuel in a bioventing process for bioremediation of diesel contaminated soil. Two laboratory-scale soil columns were packed with 5 kg of soil that was artificially contaminated by diesel fuel as final TPH (total petroleum hydrocarbon) concentration of 8,000 mg/kg soil. Nutrient was added to make a relative concentration of C:N:P = 100:10:1. One soil column was operated with continuous venting mode, and the other one with intermittent (6 h venting/6 h rest) venting mode. On-line O2 and CO2 gas measuring system was applied to measure O2 utilisation and CO2 production during biodegradation of diesel for 5 months. Biodegradation rate of TPH was calculated from respiration rate measured by the on-line gas measuring system. There were no apparent differences between calculated biodegradation rates from two columns with different venting modes. The variation of biodegradation rates corresponded well with trend of the remaining TPH concentrations comparing other biodegradation indicators, such as C17/pristane and C18/phytane ratio, dehydrogenase activity, and the ratio of hydrocarbon utilising bacteria to total heterotrophic bacteria. These results suggested that the on-line measuring system of respiration rate would be applied to monitoring biodegradation rate and to determine the potential applicability of bioventing process for bioremediation of oil contaminated soil.

  9. Price and utilisation differences for statins between four countries.

    PubMed

    Thai, Loc Phuoc; Vitry, Agnes Isabelle; Moss, John Robert

    2018-02-01

    Australia, England, France and New Zealand use different policies to regulate their medicines market, which can impact on utilisation and price. To compare the prices and utilisation of statins in Australia, England, France and New Zealand from 2011 to 2013. Utilisation of statins in the four countries was compared using Defined Daily Doses (DDD) per 1000 inhabitants per year. Pairwise Laspeyres and Paasche index comparisons were conducted comparing the price and utilisation of statins. The results showed that the price of statins in New Zealand was the cheapest. The price of statins in Australia was most expensive in 2011 and 2012 but France was more expensive in 2013. There were large differences between the Laspeyres index and Paasche index when comparing the price and utilisation of England with Australia and France. The policies that regulate the New Zealand and England medicines markets were more effective in reducing the price of expensive statins. The relative utilisation of cheaper statins was greatest in England and had a large effect on the differences between the two index results. The pricing policies in Australia have been only partly effective in reducing the price of statins compared to other countries.

  10. Univariate and multivariate spatial models of health facility utilisation for childhood fevers in an area on the coast of Kenya.

    PubMed

    Ouma, Paul O; Agutu, Nathan O; Snow, Robert W; Noor, Abdisalan M

    2017-09-18

    Precise quantification of health service utilisation is important for the estimation of disease burden and allocation of health resources. Current approaches to mapping health facility utilisation rely on spatial accessibility alone as the predictor. However, other spatially varying social, demographic and economic factors may affect the use of health services. The exclusion of these factors can lead to the inaccurate estimation of health facility utilisation. Here, we compare the accuracy of a univariate spatial model, developed only from estimated travel time, to a multivariate model that also includes relevant social, demographic and economic factors. A theoretical surface of travel time to the nearest public health facility was developed. These were assigned to each child reported to have had fever in the Kenya demographic and health survey of 2014 (KDHS 2014). The relationship of child treatment seeking for fever with travel time, household and individual factors from the KDHS2014 were determined using multilevel mixed modelling. Bayesian information criterion (BIC) and likelihood ratio test (LRT) tests were carried out to measure how selected factors improve parsimony and goodness of fit of the time model. Using the mixed model, a univariate spatial model of health facility utilisation was fitted using travel time as the predictor. The mixed model was also used to compute a multivariate spatial model of utilisation, using travel time and modelled surfaces of selected household and individual factors as predictors. The univariate and multivariate spatial models were then compared using the receiver operating area under the curve (AUC) and a percent correct prediction (PCP) test. The best fitting multivariate model had travel time, household wealth index and number of children in household as the predictors. These factors reduced BIC of the time model from 4008 to 2959, a change which was confirmed by the LRT test. Although there was a high correlation of the two modelled probability surfaces (Adj R 2  = 88%), the multivariate model had better AUC compared to the univariate model; 0.83 versus 0.73 and PCP 0.61 versus 0.45 values. Our study shows that a model that uses travel time, as well as household and individual-level socio-demographic factors, results in a more accurate estimation of use of health facilities for the treatment of childhood fever, compared to one that relies on only travel time.

  11. Better health outcomes at lower costs: the benefits of primary care utilisation for chronic disease management in remote Indigenous communities in Australia's Northern Territory.

    PubMed

    Zhao, Yuejen; Thomas, Susan L; Guthridge, Steven L; Wakerman, John

    2014-10-04

    Indigenous residents living in remote communities in Australia's Northern Territory experience higher rates of preventable chronic disease and have poorer access to appropriate health services compared to other Australians. This study compared health outcomes and costs at different levels of primary care utilisation to determine if primary care represents an efficient use of resources for Indigenous patients with common chronic diseases namely hypertension, diabetes, ischaemic heart disease, chronic obstructive pulmonary disease and renal disease. This was an historical cohort study involving a total of 14,184 Indigenous residents, aged 15 years and over, who lived in remote communities and used a remote clinic or public hospital from 2002 to 2011. Individual level demographic and clinical data were drawn from primary care and hospital care information systems using a unique patient identifier. A propensity score was used to improve comparability between high, medium and low primary care utilisation groups. Incremental cost-effectiveness ratios and acceptability curves were used to analyse four health outcome measures: total and, avoidable hospital admissions, deaths and years of life lost. Compared to the low utilisation group, medium and high levels of primary care utilisation were associated with decreases in total and avoidable hospitalisations, deaths and years of life lost. Higher levels of primary care utilisation for renal disease reduced avoidable hospitalisations by 82-85%, deaths 72-75%, and years of life lost 78-81%. For patients with ischaemic heart disease, the reduction in avoidable hospitalisations was 63-78%, deaths 63-66% and years of life lost 69-73%. In terms of cost-effectiveness, primary care for renal disease and diabetes ranked as more cost-effective, followed by hypertension and ischaemic heart disease. Primary care for chronic obstructive pulmonary disease was the least cost-effective of the five conditions. Primary care in remote Indigenous communities was shown to be associated with cost-savings to public hospitals and health benefits to individual patients. Investing $1 in primary care in remote Indigenous communities could save $3.95-$11.75 in hospital costs, in addition to health benefits for individual patients. These findings may have wider applicability in strengthening primary care in the face of high chronic disease prevalence globally.

  12. Utilisation of general practitioner services by socio-economic disadvantage and geographic remoteness.

    PubMed

    Turrell, Gavin; Oldenburg, Brian F; Harris, Elizabeth; Jolley, Damien

    2004-04-01

    To examine the association between socio-economic status (SES) and GP utilisation across Statistical Local Areas (SLAs) that differed in their geographic remoteness, and to assess whether Indigenous status and GP availability modified the association. Retrospective analysis of Medicare data for all unreferred GP consultations (1996/97) for 952 SLAs comprising the six Australian States. Geographic remoteness was ascertained using the Area Remoteness Index of Australia (ARIA), and SES was measured by grouping SLAs into tertiles based on their Index of Relative Socioeconomic Disadvantage score. Age/sex standardised rates of GP utilisation for each SLA. In SLAs classified as 'highly accessible', rates of GP use were 10.8% higher (95% CI 5.7-16.0) in the most socio-economically disadvantaged tertile after adjustment for Indigenous status and GP availability. A very different pattern of GP utilsation was found in 'remote/very remote' SLAs. After adjustment, rates of GP use in the most socio-economically disadvantaged tertile were 25.3% lower (95% CI 5.9-40.7) than in the most advantaged tertile. People in socio-economically disadvantaged metropolitan SLAs have higher rates of GP utilisation, as would be expected due to their poorer health. This is not true for people living in disadvantaged remote/very remote SLAs: in these areas, those most in need of GP services are least likely to receive them. Australia may lay claim to having a primary health care system that provides universal coverage, but we are still some way from having a system that is economically and geographically accessible to all.

  13. Does charging different user fees for primary and secondary care affect first-contacts with primary healthcare? A systematic review.

    PubMed

    Hone, Thomas; Lee, John Tayu; Majeed, Azeem; Conteh, Lesong; Millett, Christopher

    2017-06-01

    Policy-makers are increasingly considering charging users different fees between primary and secondary care (differential user charges) to encourage utilisation of primary health care in health systems with limited gate keeping. A systematic review was conducted to evaluate the impact of introducing differential user charges on service utilisation. We reviewed studies published in MEDLINE, EMBASE, the Cochrane library, EconLIT, HMIC, and WHO library databases from January 1990 until June 2015. We extracted data from the studies meeting defined eligibility criteria and assessed study quality using an established checklist. We synthesized evidence narratively. Eight studies from six countries met our eligibility criteria. The overall study quality was low, with diversity in populations, interventions, settings, and methods. Five studies examined the introduction of or increase in user charges for secondary care, with four showing decreased secondary care utilisation, and three showing increased primary care utilisation. One study identified an increase in primary care utilisation after primary care user charges were reduced. The introduction of a non-referral charge in secondary care was associated with lower primary care utilisation in one study. One study compared user charges across insurance plans, associating higher charges in secondary care with higher utilisation in both primary and secondary care. Overall, the impact of introducing differential user-charges on primary care utilisation remains uncertain. Further research is required to understand their impact as a demand side intervention, including implications for health system costs and on utilisation among low-income patients. © The Author 2017. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  14. Factors that influence utilisation of HIV/AIDS prevention methods among university students residing at a selected university campus.

    PubMed

    Ndabarora, Eléazar; Mchunu, Gugu

    2014-01-01

    Various studies have reported that university students, who are mostly young people, rarely use existing HIV/AIDS preventive methods. Although studies have shown that young university students have a high degree of knowledge about HIV/AIDS and HIV modes of transmission, they are still not utilising the existing HIV prevention methods and still engage in risky sexual practices favourable to HIV. Some variables, such as awareness of existing HIV/AIDS prevention methods, have been associated with utilisation of such methods. The study aimed to explore factors that influence use of existing HIV/AIDS prevention methods among university students residing in a selected campus, using the Health Belief Model (HBM) as a theoretical framework. A quantitative research approach and an exploratory-descriptive design were used to describe perceived factors that influence utilisation by university students of HIV/AIDS prevention methods. A total of 335 students completed online and manual questionnaires. Study findings showed that the factors which influenced utilisation of HIV/AIDS prevention methods were mainly determined by awareness of the existing university-based HIV/AIDS prevention strategies. Most utilised prevention methods were voluntary counselling and testing services and free condoms. Perceived susceptibility and perceived threat of HIV/AIDS score was also found to correlate with HIV risk index score. Perceived susceptibility and perceived threat of HIV/AIDS showed correlation with self-efficacy on condoms and their utilisation. Most HBM variables were not predictors of utilisation of HIV/AIDS prevention methods among students. Intervention aiming to improve the utilisation of HIV/AIDS prevention methods among students at the selected university should focus on removing identified barriers, promoting HIV/AIDS prevention services and providing appropriate resources to implement such programmes.

  15. A systematic review of outcome measures utilised to assess self-management in clinical trials in patients with chronic pain.

    PubMed

    Banerjee, Anirban; Hendrick, Paul; Bhattacharjee, Purba; Blake, Holly

    2018-05-01

    The aim of this review was to identify, appraise and synthesise the outcome measures used to assess self-management in patients with chronic pain. Medline, Embase, CINAHL, PsycINFO, the Cochrane Library and Google Scholar were searched to identify quantitative measures used within randomised or non-randomised clinical trials to assess self-management in adults (≥18 years) with chronic pain. 25 RCTs published between 1998 and 2016 were included in this review. Studies included patients with chronic pain, hip/knee osteoarthritis, rheumatoid arthritis, chronic low back pain, fibromyalgia and chronic fatigue syndrome. Included studies utilised 14 different measures assessing a variety of constructs including self-efficacy (n = 19), coping (n = 4), empowerment (n = 2), pain attitude and management (n = 3), self-care (n = 1), role behaviour (n = 1) and multiple constructs of self-management (n = 1). The Chronic Pain Coping Inventory (CPCI) and Health Education Impact Questionnaire (heiQ) cover different self-management related constructs across the physical, mental and social health domains. The review identified 14 measures used as proxy measure to assess self-management in patients with chronic pain. These measures have good content and construct validity, and internal consistency. However additional research is required to develop their reliability, responsiveness and interpretability. Multi-constructs measures (CPCI, heiQ) are suitable for assessing self-management. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Left atrial function: evaluation by strain analysis

    PubMed Central

    Gan, Gary C. H.; Ferkh, Aaisha; Boyd, Anita

    2018-01-01

    The left atrium has an important role in modulating left ventricular filling and is an important biomarker of cardiovascular disease and adverse cardiovascular outcomes. While previously left atrial (LA) size was utilised, the role of LA function as a biomarker is increasingly being evaluated, both independently and also in combination with LA size. Strain analysis has been utilised for evaluation of LA function and can be measured throughout the cardiac cycle, thereby enabling the evaluation of LA reservoir, conduit and contractile function. Strain evaluates myocardial deformation while strain rate examines the rate of change in strain. This review will focus on the various types of strain analysis for evaluation of LA function, alterations in LA strain in physiological and pathologic states that alter LA function and finally evaluate its utility as a prognostic marker. PMID:29541609

  17. Factors affecting Japanese retirees' healthcare service utilisation in Malaysia: a qualitative study.

    PubMed

    Kohno, Ayako; Nik Farid, Nik Daliana; Musa, Ghazali; Abdul Aziz, Norlaili; Nakayama, Takeo; Dahlui, Maznah

    2016-03-22

    While living overseas in another culture, retirees need to adapt to a new environment but often this causes difficulties, particularly among those elderly who require healthcare services. This study examines factors affecting healthcare service utilisation among Japanese retirees in Malaysia. We conducted 6 focus group discussions with Japanese retirees and interviewed 8 relevant medical services providers in-depth. Guided by the Andersen Healthcare Utilisation Model, we managed and analysed the data, using QSR NVivo 10 software and the directed content analysis method. We interviewed participants at Japan Clubs and their offices. 30 Japanese retirees who live in Kuala Lumpur and Ipoh, and 8 medical services providers. We identified health beliefs, medical symptoms and health insurance as the 3 most important themes, respectively, representing the 3 dimensions within the Andersen Healthcare Utilisation Model. Additionally, language barriers, voluntary health repatriation to Japan and psychological support were unique themes that influence healthcare service utilisation among Japanese retirees. The healthcare service utilisation among Japanese retirees in Malaysia could be partially explained by the Andersen Healthcare Utilisation Model, together with some factors that were unique findings to this study. Healthcare service utilisation among Japanese retirees in Malaysia could be improved by alleviating negative health beliefs through awareness programmes for Japanese retirees about the healthcare systems and cultural aspects of medical care in Malaysia. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  18. Navy Libraries’ Information Storage and Retrieval System. Proceedings of the CONSATL Workshop and Meeting (38th), 23-25 April 1980,

    DTIC Science & Technology

    1981-04-01

    1606 David Taylor Naval Ship R&D Center (202)227- 1307 Mary Jane Brewster Naval Research Laboratory Donald R. Erickson AV 297-3425 Naval Sea Systems...Marshal Hughes Nannette M. Pope Naval Surface Weapons Center Armed Forces Radiobiology Research AV 249-8994 Institute (703)663-8994 (301)295- 0428

  19. Proceedings of the first international symposium on neutron capture therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fairchild, R.G.; Brownell, G.L.

    This meeting was arranged jointly by MIT and BNL in order to illuminate progress in the synthesis and targeting of boron compounds and to evaluate and document progress in radiobiological and dosimetric aspects of neutron capture therapy. It is hoped that this meeting will facilitate transfer of information between groups working in these fields, and encourage synergistic collaboration.

  20. AFRRI (Armed Forces Radiobiology Research Institute) Reports, January, February, March 1987.

    DTIC Science & Technology

    1987-04-01

    clinical evaluation in the management of cancer patients with fever tract in animals exposed to less radiation. It is possible that when and...strain BCG, muramyl dipeptide (MDP) or glucan have radioprotective effect when administered prior to irradiation. The immunomodulatory substances are...Immunoregulation, National Cancer Institute, Frederick Cancer Research Facility. Frederick. MD 21701 ABSTRACT Immunomodulatory agents are radioprotective

  1. Masculinity, Educational Achievement and Social Status: A Social Network Analysis

    ERIC Educational Resources Information Center

    Lusher, Dean

    2011-01-01

    This study utilises a quantitative case study social network approach to explore the connection between masculinity and scholastic achievement in two secondary, all-boys schools in Australia. In both schools two social networks representing social status are explored: the "friendship" network as a measure of status that includes…

  2. The Nature of Reflective Practice and Emotional Intelligence in Tutorial Settings

    ERIC Educational Resources Information Center

    Gill, Gobinder Singh

    2014-01-01

    The purpose of this paper was to assess the nature of reflective practice and emotional intelligence in tutorial settings. Following the completion of a self-report measure of emotional intelligence, practitioners incorporated a model of reflective practice into their tutorial sessions. Practitioners were instructed to utilise reflective practice…

  3. Prosodic Awareness and Children's Multisyllabic Word Reading

    ERIC Educational Resources Information Center

    Holliman, Andrew J.; Mundy, Ian R.; Wade-Woolley, Lesly; Wood, Clare; Bird, Chelsea

    2017-01-01

    Prosodic awareness (the rhythmic patterning of speech) accounts for unique variance in reading development. However, studies have thus far focused on early readers and utilised literacy measures which fail to distinguish between monosyllabic and multisyllabic words. The current study investigated the factors that are specifically associated with…

  4. 3D-modelling of radon-induced cellular radiobiological effects in bronchial airway bifurcations: direct versus bystander effects.

    PubMed

    Szőke, István; Farkas, Arpád; Balásházy, Imre; Hofmann, Werner; Madas, Balázs G; Szőke, Réka

    2012-06-01

    The primary objective of this paper was to investigate the distribution of radiation doses and the related biological responses in cells of a central airway bifurcation of the human lung of a hypothetical worker of the New Mexico uranium mines during approximately 12 hours of exposure to short-lived radon progenies. State-of-the-art computational modelling techniques were applied to simulate the relevant biophysical and biological processes in a central human airway bifurcation. The non-uniform deposition pattern of inhaled radon daughters caused a non-uniform distribution of energy deposition among cells, and of related cell inactivation and cell transformation probabilities. When damage propagation via bystander signalling was assessed, it produced more cell killing and cell transformation events than did direct effects. If bystander signalling was considered, variations of the average probabilities of cell killing and cell transformation were supra-linear over time. Our results are very sensitive to the radiobiological parameters, derived from in vitro experiments (e.g., range of bystander signalling), applied in this work and suggest that these parameters may not be directly applicable to realistic three-dimensional (3D) epithelium models.

  5. Nonlinear dose response model with repair and repair suppression

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leonard, B.E.

    1996-12-31

    In March 1996, the Health Physics Society issued a position statement supporting a nonlinear threshold (NLT) concept for radiation risk at low-dose/low-dose-rate (LD/LDR) levels. This action was after receipt of an overwhelming consensus from world-renown radiobiologists and is contrary to the opinions of the United Nations Scientific Committee on Effects of Atomic Radiation, the National Research Council Committee on the Biological Effects of Ionizing Radiations, and U.S. Environmental Protection Agency. Alvarez and others have called for a new NLT model for radiation risk. Two mathematical models have historically been used to describe cell survival experimental results. Each provides the abilitymore » to account for the shoulder observed in cell survival curves, predominantly for low-linear energy transfer (LET) radiation, and the wide variation in radio sensitivity of cell species and particular phase of the mitotic cycle. Only Kellerer and Rossi, Elkind and Whitmore, and Green and Burki have proposed modified models explicitly incorporating radiobiological repair and departing from LNT. None of these were subsequently used with any extent of success in cell survival analysis. The author reports initial work on a program to reexamine radiobiology research exhibiting repair processes at LD/LDR levels.« less

  6. THE CYTOLOGY AND GENETICS OF RADIATION RESISTANCE IN BACTERIA. Progress Report for the Period of November 1, 1955 to November 1, 1956

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1960-10-31

    Cytogenetic procedures, applicable to microbiology, were selected and tested on a suitable organism as a basis for the valid application of these procedures to other microorganisms. Nocardia corallina was chosen as a test organism on the basis of preliminary cytological studies. The crystal violet nuclear stain, the thionin-SO/sub 2/ nuclear stain, the crystal violet-tannic acid-congo red cell wall stain, and phase microscopy, were found to be valid tools of microbial cytology if interpreted with restraint. The correlation of cytological and radiobiological findings demonstrated that, in N. corallina, a diploid coccoidal stage, gives rise to a coenocytic diploid hypbal stage whichmore » fragments through a nuclear reduction division to form haploid dinucleated bacillary cells. The bacillary cell nuclei fuse and the cell divides to form diploid coccoids. The haploid chromosome number is suggested as three for this organism. It has been demonstrated that a microbial cytogenetic approach involving the correlation and integration of cytological procedures with genetic and radiobiological methods can aid in solving basic problems of microbial cytology and genetics. (For preceding period see ORO-282.) (auth)« less

  7. Research needed for improving heavy-ion therapy

    NASA Astrophysics Data System (ADS)

    Kraft, G; Kraft, S D

    2009-02-01

    The large interest in heavy-ion therapy is stimulated from its excellent clinical results. The bases of this success are the radiobiological and physical advantages of heavy-ion beams and the active beam delivery used for an intensity-modulated particle radiotherapy (IMPT). Although heavy-ion therapy has reached a high degree of perfection for clinical use there is still large progress possible to improve this novel technique: in order to extend IMPT to more tumor entities and to tailor the planning more individually for each patient in an adaptive way, radiobiological work is required both experimentally and theoretically. It is also not clear whether the neighboring ions to carbon could have a clinical application as well. For this extension basic biological studies as well as physics experiments have to be performed. On the technical side, many improvements of the equipment used seem to be possible. Two major topics are the extension of IMPT to moving organs and the transition to more compact and therefore cheaper particle accelerators. In the present paper, these topics are treated to some extent in order to give an outline of the great future potential of ion-beam therapy.

  8. Biological effective dose evaluation in gynaecological brachytherapy: LDR and HDR treatments, dependence on radiobiological parameters, and treatment optimisation.

    PubMed

    Bianchi, C; Botta, F; Conte, L; Vanoli, P; Cerizza, L

    2008-10-01

    This study was undertaken to compare the biological efficacy of different high-dose-rate (HDR) and low-dose-rate (LDR) treatments of gynaecological lesions, to identify the causes of possible nonuniformity and to optimise treatment through customised calculation. The study considered 110 patients treated between 2001 and 2006 with external beam radiation therapy and/or brachytherapy with either LDR (afterloader Selectron, (137)Cs) or HDR (afterloader microSelectron Classic, (192)Ir). The treatments were compared in terms of biologically effective dose (BED) to the tumour and to the rectum (linear-quadratic model) by using statistical tests for comparisons between independent samples. The difference between the two treatments was statistically significant in one case only. However, within each technique, we identified considerable nonuniformity in therapeutic efficacy due to differences in fractionation schemes and overall treatment time. To solve this problem, we created a Microsoft Excel spreadsheet allowing calculation of the optimal treatment for each patient: best efficacy (BED(tumour)) without exceeding toxicity threshold (BED(rectum)). The efficacy of a treatment may vary as a result of several factors. Customised radiobiological evaluation is a useful adjunct to clinical evaluation in planning equivalent treatments that satisfy all dosimetric constraints.

  9. Radiobiological Implications of Fukushima Nuclear Accident for Personalized Medical Approach.

    PubMed

    Fukunaga, Hisanori; Yokoya, Akinari; Taki, Yasuyuki; Prise, Kevin M

    2017-05-01

    On March 11, 2011, a devastating earthquake and subsequent tsunami caused serious damage to areas of the Pacific coast in Fukushima prefecture and prompted fears among the residents about a possible meltdown of the Fukushima Daiichi Nuclear Power Plant reactors. As of 2017, over six years have passed since the Fukushima nuclear crisis and yet the full ramifications of the biological exposures to this accidental release of radioactive substances remain unclear. Furthermore, although several genetic studies have determined that the variation in radiation sensitivity among different individuals is wider than expected, personalized medical approaches for Fukushima victims have seemed to be insufficient. In this commentary, we discuss radiobiological issues arising from low-dose radiation exposure, from the cell-based to the population level. We also introduce the scientific utility of the Integrative Japanese Genome Variation Database (iJGVD), an online database released by the Tohoku Medical Megabank Organization, Tohoku University that covered the whole genome sequences of 2,049 healthy individuals in the northeastern part of Japan in 2016. Here we propose a personalized radiation risk assessment and medical approach, which considers the genetic variation of radiation sensitivity among individuals, for next-step developments in radiological protection.

  10. Volume effects of late term normal tissue toxicity in prostate cancer radiotherapy

    NASA Astrophysics Data System (ADS)

    Bonta, Dacian Viorel

    Modeling of volume effects for treatment toxicity is paramount for optimization of radiation therapy. This thesis proposes a new model for calculating volume effects in gastro-intestinal and genito-urinary normal tissue complication probability (NTCP) following radiation therapy for prostate carcinoma. The radiobiological and the pathological basis for this model and its relationship to other models are detailed. A review of the radiobiological experiments and published clinical data identified salient features and specific properties a biologically adequate model has to conform to. The new model was fit to a set of actual clinical data. In order to verify the goodness of fit, two established NTCP models and a non-NTCP measure for complication risk were fitted to the same clinical data. The method of fit for the model parameters was maximum likelihood estimation. Within the framework of the maximum likelihood approach I estimated the parameter uncertainties for each complication prediction model. The quality-of-fit was determined using the Aikaike Information Criterion. Based on the model that provided the best fit, I identified the volume effects for both types of toxicities. Computer-based bootstrap resampling of the original dataset was used to estimate the bias and variance for the fitted parameter values. Computer simulation was also used to estimate the population size that generates a specific uncertainty level (3%) in the value of predicted complication probability. The same method was used to estimate the size of the patient population needed for accurate choice of the model underlying the NTCP. The results indicate that, depending on the number of parameters of a specific NTCP model, 100 (for two parameter models) and 500 patients (for three parameter models) are needed for accurate parameter fit. Correlation of complication occurrence in patients was also investigated. The results suggest that complication outcomes are correlated in a patient, although the correlation coefficient is rather small.

  11. Physics and biophysics experiments needed for improved risk assessment in space

    NASA Astrophysics Data System (ADS)

    Sihver, L.

    To improve the risk assessment of radiation carcinogenesis, late degenerative tissue effects, acute syndromes, synergistic effects of radiation and microgravity or other spacecraft factors, and hereditary effects, on future LEO and interplanetary space missions, the radiobiological effects of cosmic radiation before and after shielding must be well understood. However, cosmic radiation is very complex and includes low and high LET components of many different neutral and charged particles. The understanding of the radiobiology of the heavy ions, from GCRs and SPEs, is still a subject of great concern due to the complicated dependence of their biological effects on the type of ion and energy, and its interaction with various targets both outside and within the spacecraft and the human body. In order to estimate the biological effects of cosmic radiation, accurate knowledge of the physics of the interactions of both charged and non-charged high-LET particles is necessary. Since it is practically impossible to measure all primary and secondary particles from all projectile-target-energy combinations needed for a correct risk assessment in space, accurate particle and heavy ion transport codes might be a helpful instrument to overcome those difficulties. These codes have to be carefully validated to make sure they fulfill preset accuracy criteria, e.g. to be able to predict particle fluence and energy distributions within a certain accuracy. When validating the accuracy of the transport codes, both space and ground-based accelerator experiments are needed. In this paper current and future physics and biophysics experiments needed for improved risk assessment in space will be discussed. The cyclotron HIRFL (heavy ion research facility in Lanzhou) and the new synchrotron CSR (cooling storage ring), which can be used to provide ion beams for space related experiments at the Institute of Modern Physics, Chinese Academy of Sciences (IMP-CAS), will be presented together with the physical and biomedical research performed at IMP-CAS.

  12. SERS study of transformation of phenylalanine to tyrosine under particle irradiation

    NASA Astrophysics Data System (ADS)

    Zhang, Jingjing; Huang, Qing; Yao, Guohua; Ke, Zhigang; Zhang, Hong; Lu, Yilin

    2014-08-01

    Surface enhanced Raman scattering or spectroscopy (SERS) is a very powerful analytical tool which has been widely applied in many scientific research and application fields. It is therefore also very intriguing for us to introduce SERS technique in the radiobiological research, where in many cases only a very few of biomolecules are subjected to changes which however can lead to significant biological effects. The radiation induced biochemical reactions are normally very sophisticated with different substances produced in the system, so currently it is still a big challenge for SERS to analyze such a mixture system which contains multiple analytes. In this context, this work aimed to establish and consolidate the feasibility of SERS as an effective tool in radiation chemistry, and this purpose, we employed SERS as a sensitive probe to a known process, namely, the oxidation of phenylalanine (Phe) under particle irradiation, where the energetic particles were obtained from either plasma discharge or electron-beam. During the irradiation, three types of tyrosine (Tyr), namely, p-Tyr, m-Tyr and o-Tyr were produced, and all these tyrosine isomers together with Phe could be identified and measured based on the SERS spectral analysis of the corresponding enhanced characteristic signals, namely, 1002 cm-1 for Phe, 1161 cm-1 for p-Tyr, 990 cm-1 for m-Tyr, and 970 cm-1 for o-Tyr, respectively. The estimation of the quantities of different tyrosine isomers were also given and verified by conventional method such as high performance liquid chromatography (HPLC). As for comparison of different ways of particle irradiation, our results also indicated that electron-beam irradiation was more efficient for converting Phe into Tyr than plasma discharge treatment, confirming the role of hydroxyl radicals in the Phe-Tyr conformation. Therefore, our work has not only demonstrated that SERS can be successfully applied in the radiobiological study, but also given insights into the mechanism for the interaction between particle radiation and biological systems.

  13. WE-H-BRA-04: Biological Geometries for the Monte Carlo Simulation Toolkit TOPASNBio

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McNamara, A; Held, K; Paganetti, H

    2016-06-15

    Purpose: New advances in radiation therapy are most likely to come from the complex interface of physics, chemistry and biology. Computational simulations offer a powerful tool for quantitatively investigating radiation interactions with biological tissue and can thus help bridge the gap between physics and biology. The aim of TOPAS-nBio is to provide a comprehensive tool to generate advanced radiobiology simulations. Methods: TOPAS wraps and extends the Geant4 Monte Carlo (MC) simulation toolkit. TOPAS-nBio is an extension to TOPAS which utilizes the physics processes in Geant4-DNA to model biological damage from very low energy secondary electrons. Specialized cell, organelle and molecularmore » geometries were designed for the toolkit. Results: TOPAS-nBio gives the user the capability of simulating biological geometries, ranging from the micron-scale (e.g. cells and organelles) to complex nano-scale geometries (e.g. DNA and proteins). The user interacts with TOPAS-nBio through easy-to-use input parameter files. For example, in a simple cell simulation the user can specify the cell type and size as well as the type, number and size of included organelles. For more detailed nuclear simulations, the user can specify chromosome territories containing chromatin fiber loops, the later comprised of nucleosomes on a double helix. The chromatin fibers can be arranged in simple rigid geometries or within factual globules, mimicking realistic chromosome territories. TOPAS-nBio also provides users with the capability of reading protein data bank 3D structural files to simulate radiation damage to proteins or nucleic acids e.g. histones or RNA. TOPAS-nBio has been validated by comparing results to other track structure simulation software and published experimental measurements. Conclusion: TOPAS-nBio provides users with a comprehensive MC simulation tool for radiobiological simulations, giving users without advanced programming skills the ability to design and run complex simulations.« less

  14. WE-H-BRA-02: Radiobiological Modeling of Tumor Control Probability (TCP) and Radiation-Induced Pneumonitis (RP) for Lung Cancer Patients Treated with Monte Carlo-Based Lung SBRT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pokhrel, D; Sood, S; Shen, X

    2016-06-15

    Purpose: To present radiobiological modeling of TCP using tumor size-adjusted BED(s-BED)and PTV(D99) to lung SBRT patients treated with X-ray Voxel Monte Carlo(XVMC) algorithm, apply parameterized Lyman-NTCP model to predict grade-2 RP and subsequently, compare with clinical outcomes/observations. Methods: Dosimetric parameters and clinical follow-up for XVMC-based lung-SBRT patients were retrospectively evaluated. Patients were treated at Novalis-TX with hybrid(2 non-coplanar partial-arcs plus 3–6 static-beams)plan using HD-MLC/6MV-SRS-beam.For TCP,s-BED modelling was utilized: TCP=EXP[sBED-TCD50]/k/(1.0+EXP[sBED-TCD50]/k), where k=31Gy corresponding to TCD50=0Gy and s-BED was defined as BED10 minus 10 times the tumor diameter(in centimeters)by Ohri et al.(IJROBP,2012). For 2-yr local-control, we used more-realistic MC-computed PTVD99 as amore » predictive parameter, s-BED(D99).Due to relatively shorter median follow-up interval(12-months),Kaplan-Meier curves were generated to estimate 2-yr observed local-control and compared to predicted-rate by TCP modeling. For NTCP, we employed parameterized Lyman-NTCP model utilizing normal-lung DVH and α/β=3Gy fitted to predict grade-2 RP after lung-SBRT. Results: Total 108 patients (137 tumors) treated for 35–70Gy in 3–5 fractions, either primary-lung(n=74)or metastatic-lung(n=53)tumors were included.F or the given prescription dose with MC-computed MUs, 2-yr local-control rates with s-BED(D99) was 87±8%. Kaplan-Meier generated observed local-control rate at 2-yr was 87.5%,suggesting that PTV(D99) could be a potential predictor (p-value=0.38). Observed vs predicted TCP for primary-lung tumors and metastatic tumors were 97% vs 88±7% and 94% vs 86±9%.NTCP model predicted well for symptomatic-RP with predicted vs observed (3±5% vs 2%). Radiographic and clinically significant RP was observed in 13% and 2% of patients. Higher rates of radiographic change were observed in patients who received >50Gy compared to ≤50Gy(24% vs 10%). Conclusion: Utilizing MC-computed PTVD99, our TCP results were well correlated with clinical outcome. The predicted grade-2 RP rate was comparable to clinical observations. Clinical application of these radiobiological models may potentially allow for target dose escalation and/or lung-toxicity reduction. Further validation of these radiobiological models with longer follow up interval for large cohorts of lung-SBRT patients is anticipated.« less

  15. Health service utilisation amongst urban Aboriginal and Torres Strait Islander children aged younger than 5 years registered with a primary health-care service in South-East Queensland.

    PubMed

    Hall, Kerry K; Chang, Anne B; Anderson, Jennie; Arnold, Daniel; Otim, Michael; O'Grady, Kerry-Ann F

    2018-06-01

    The majority of Australia's Aboriginal and/or Torres Strait Islander children live in urban areas; however, little is known about their health service use. We aimed to describe health service utilisation amongst a cohort of urban Aboriginal and/or Torres Strait Islander children aged <5 years. We analysed health service utilisation data collected in an ongoing prospective cohort study of children aged <5 years registered with an Aboriginal-owned and operated primary health-care service. Enrolled children were followed monthly for 12 months, with data on health service utilisation collected at baseline and at each monthly follow-up. Health service utilisation rates, overall and by service provider and reason for presentation, were calculated and reported as incidence rates per 100 child-months with the corresponding 95% confidence intervals (CIs). Between February 2013 and November 2015, 180 children were enrolled, and 1541 child-months of observation were available for analysis. The overall incidence of health service utilisation was 52.5 per 100 child-months (95% CI 48.7-56.5); 81% of encounters were with general practitioners. Presentation rates were the highest for acute respiratory illnesses (30.7/100 child-months, 95% CI 27.8-33.9). In this community, acute respiratory illnesses are predominant causes of health service utilisation in young children. The health-care utilisation profile of these children presents important opportunities for health promotion and intervention. © 2018 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).

  16. The experiences of culturally and linguistically diverse family caregivers in utilising dementia services in Australia

    PubMed Central

    2013-01-01

    Background Older people from culturally and linguistically diverse groups are underrepresented in residential aged care but overrepresented in community aged care in Australia. However, little is known about culturally and linguistically diverse family caregivers in utilising dementia services in Australia because previous studies mainly focused on the majority cultural group. Experiences of caregivers from culturally and linguistically diverse groups who are eligible to utilise dementia services in Australia are needed in order to optimize the utilisation of dementia services for these caregivers. Methods The aim of the study was to explore the experiences of family caregivers from Chinese, Greek, Italian and Vietnamese groups in utilising dementia services. Gadamer's philosophical hermeneutics was used to interpret the experiences of the participants. Focus group discussions and in-depth individual interviews were used to collect data. Data collection was conducted over a six month period in 2011. In total, 46 family caregivers who were caring for 39 persons with dementia participated. Results Four themes were revealed: (1) negotiating services for the person with dementia; (2) the impact of acculturation on service utilisation; (3) the characteristics of satisfactory services; and (4) negative experiences in utilising services. The present study revealed that the participation of caregivers from culturally and linguistically diverse groups in planning and managing dementia services ranged markedly from limited participation to full participation. Conclusions The findings of this study suggest that caregivers from culturally and linguistically diverse groups need to be fully prepared so they can participate in the utilisation of dementia services available to them in Australia. PMID:24148155

  17. The experiences of culturally and linguistically diverse family caregivers in utilising dementia services in Australia.

    PubMed

    Xiao, Lily Dongxia; De Bellis, Anita; Habel, Lesley; Kyriazopoulos, Helena

    2013-10-22

    Older people from culturally and linguistically diverse groups are underrepresented in residential aged care but overrepresented in community aged care in Australia. However, little is known about culturally and linguistically diverse family caregivers in utilising dementia services in Australia because previous studies mainly focused on the majority cultural group. Experiences of caregivers from culturally and linguistically diverse groups who are eligible to utilise dementia services in Australia are needed in order to optimize the utilisation of dementia services for these caregivers. The aim of the study was to explore the experiences of family caregivers from Chinese, Greek, Italian and Vietnamese groups in utilising dementia services. Gadamer's philosophical hermeneutics was used to interpret the experiences of the participants. Focus group discussions and in-depth individual interviews were used to collect data. Data collection was conducted over a six month period in 2011. In total, 46 family caregivers who were caring for 39 persons with dementia participated. Four themes were revealed: (1) negotiating services for the person with dementia; (2) the impact of acculturation on service utilisation; (3) the characteristics of satisfactory services; and (4) negative experiences in utilising services. The present study revealed that the participation of caregivers from culturally and linguistically diverse groups in planning and managing dementia services ranged markedly from limited participation to full participation. The findings of this study suggest that caregivers from culturally and linguistically diverse groups need to be fully prepared so they can participate in the utilisation of dementia services available to them in Australia.

  18. Radiation dosimetry and biophysical models of space radiation effects

    NASA Technical Reports Server (NTRS)

    Cucinotta, Francis A.; Wu, Honglu; Shavers, Mark R.; George, Kerry

    2003-01-01

    Estimating the biological risks from space radiation remains a difficult problem because of the many radiation types including protons, heavy ions, and secondary neutrons, and the absence of epidemiology data for these radiation types. Developing useful biophysical parameters or models that relate energy deposition by space particles to the probabilities of biological outcomes is a complex problem. Physical measurements of space radiation include the absorbed dose, dose equivalent, and linear energy transfer (LET) spectra. In contrast to conventional dosimetric methods, models of radiation track structure provide descriptions of energy deposition events in biomolecules, cells, or tissues, which can be used to develop biophysical models of radiation risks. In this paper, we address the biophysical description of heavy particle tracks in the context of the interpretation of both space radiation dosimetry and radiobiology data, which may provide insights into new approaches to these problems.

  19. The effect of X-ray scattering by water in the irradiation of cell cultures for the dosimetric characterization of a new prototype of IORT (Intra-Operative Radiation Therapy) device: Monte Carlo simulation and experimental validation.

    PubMed

    Ceccolini, E; Ferrari, P; Castelluccio, D M; Mostacci, D; Sumini, M

    2013-10-01

    The electron beam emitted backward by plasma focus devices is being considered as a radiation source for Intra-Operative Radiation Therapy (IORT) applications. Radiobiological investigations have been conducted to assess the potential of this new prototype of IORT device. A standard x-ray beam, ISO-H60, was used for comparison, irradiating cell cultures in a holder filled with an aqueous solution. The influence of scattering by the culture water and by the walls of the holder was investigated to determine their influence on the dose delivered to the cell culture. MCNPX simulations were run and experimental measurements conducted. The effect of scattering by the holder was found to be negligible; scattering by the culture water was determined to give an increase in dose of the order of 10%.

  20. Conception and realization of a parallel-plate free-air ionization chamber for the absolute dosimetry of an ultrasoft X-ray beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Groetz, J.-E., E-mail: jegroetz@univ-fcomte.fr; Mavon, C.; Fromm, M.

    2014-08-15

    We report the design of a millimeter-sized parallel plate free-air ionization chamber (IC) aimed at determining the absolute air kerma rate of an ultra-soft X-ray beam (E = 1.5 keV). The size of the IC was determined so that the measurement volume satisfies the condition of charged-particle equilibrium. The correction factors necessary to properly measure the absolute kerma using the IC have been established. Particular attention was given to the determination of the effective mean energy for the 1.5 keV photons using the PENELOPE code. Other correction factors were determined by means of computer simulation (COMSOL™and FLUKA). Measurements of airmore » kerma rates under specific operating parameters of the lab-bench X-ray source have been performed at various distances from that source and compared to Monte Carlo calculations. We show that the developed ionization chamber makes it possible to determine accurate photon fluence rates in routine work and will constitute substantial time-savings for future radiobiological experiments based on the use of ultra-soft X-rays.« less

  1. Utilisation of a community-based health facility in a low-income urban community in Ibadan, Nigeria

    PubMed Central

    Asuzu, Michael C.

    2015-01-01

    Background Primary healthcare is established to ensure that people have access to health services through facilities located in their community. However, utilisation of health facilities in Nigeria remains low in many communities. Aim To assess the utilisation of community-based health facility (CBHF) amongst adults in Ibadan, Nigeria Settings A low-income community in Ibadan North West Local Government Area of Oyo State. Methods A cross-sectional survey was conducted using a simple random sampling technique to select one adult per household in all 586 houses in the community. A semi-structured interviewer-administered questionnaire was used to collect information on respondents' sociodemographic characteristics, knowledge and utilisation of the CBHF. Data analysis included descriptive statistics and association testing using the Chi-square test at p = 0.05. Results The mean age of the respondents was 46.5 ± 16.0 years; 46.0% were men and 81.0% married; 26% had no formal education and 38.0% had secondary-level education and above; traders constituted 52.0% of the sample; and 85.2% were of low socioeconomic standing; 90% had patronised the CBHF. The main reasons for non-utilisation were preference for general hospitals (13.8%) and self-medication (12.1%). Respondents who had secondary education and above, were in a higher socioeconomic class, who had good knowledge of the facility and were satisfied with care, utilised the CBHF three months significantly more than their counterparts prior to the study (p < 0.05). However, only satisfaction with care was found to be a significant predictor of utilisation of the CBHF. Conclusion The utilisation of the CBHF amongst adults in the study setting is high, driven mostly by satisfaction with the care received previously. Self-medication, promoted by uncontrolled access to drugs through pharmacies and patent medicine stores, threatens this high utilisation. PMID:26245600

  2. Armed Forces Radiobiology Research Institute Annual Research Report, Fiscal Year 1984.

    DTIC Science & Technology

    1984-01-01

    thromboxane B2, cyclic AMP and GMP, ACTH, beta -endorphin, cortisol/corticosterone, and complement in bio- logical fluids and tissues. Mediators will...immunomodulators are being tested for their ability to enhance the *recovery of hemopoiesis following irradiation. These include glucan , detoxified...endotoxin, and selected agents from the Biological Response Modifiers Program (NCI, Frederick, MD). Glucan has proved to be very effective in stimulating

  3. Biological Effects of Protracted Exposure to Ionizing Radiation: Review, Analysis, and Model Development

    DTIC Science & Technology

    1991-11-01

    dynamics, physiological changes, morphologi- cal changes, cell/tissue damage and recovery mechanisms, and existing radiobiological injury and recovery...humans and the ferret. The gut injury model (GIM) is a three-compartment hierarchial- type tissue model to simulate radiation-induced changes in the...Prodromal Symptoms Diarrhea Gastrointestinal Symptoms Dose Rate Cell Survival Intestinal Injury Fatigability Cell Damage Cell Repair Cell Proliferation

  4. History of hadrontherapy

    NASA Astrophysics Data System (ADS)

    Amaldi, Ugo

    2015-06-01

    Hadrontherapy is today an established modality in cancer radiation therapy. Based on the superior ballistic and radiobiological properties of accelerated ions, this discipline experienced a remarkable growth in the last 20 years. This paper reviews the history of hadrontherapy, from the early days to the most recent developments. In particular, the evolution of proton and carbon ion therapy is presented together with a glance at future solutions such as single-room facilities.

  5. USSR and Eastern Europe Scientific Abstracts, Biomedical and Behavioral Sciences, Number 67.

    DTIC Science & Technology

    1977-03-30

    and Ecological Problems 14 Molecular Biology 23 Pharmacology. 25 Physiology. 27 Public Health 46 Radiobiology 48 Therapy . 49 BEHAVIORAL...normalizing metabolic processes be included in the complex therapy . USSR UDC 612.3 616.3 DIGESTIBILITY OF VEGETARIAN FISH MEAT PROTEINS BY PROTEOLYTIC...inactivation of one hemisphere, arising after unilateral electroconvulsive seizure, a study was made of the intelli- gibility of phonemes (vowels and

  6. Development of Medical Technology for Contingency Response to Marrow Toxic Agents

    DTIC Science & Technology

    2012-07-26

    Armed Forces Radiobiology Research Institute’s (AFRRI) conference on advances in treating combined injuries resulting from a radiological disaster... Research on Health Effects of Radiation B-LCLs B-Lymphoblastoid Cell Lines IND Investigational New Drug BARDA Biomedical Advanced Research and...Naval Research (ONR 342) 875 N. Randolph St. Arlington, VA 22203-1995 Subject: Quartcrl~ Performance/Technical Report of the National Marrow Donor

  7. Free Radicals Mediate Peroxidative Damage in Guinea Pig Hippocampus in vitro

    DTIC Science & Technology

    1989-01-01

    Peroxidative Damage in Guinea Pig Hippocampus In Vitro T.C. Pellmar, K.L. Neel, and K.H. Lee Physiology Department. Armed Forces Radiobiology Research...removed from brains of euthanized evaluate the free radical involvement in peroxidative guinea pigs . Electrical stimulation of an orthodromic damage to...Hartley guinea pigs as previously described (Pellmar, 1986, 1987). Animals were anesthetized with halothane and euthanized by cervical dislocation

  8. Using Locata to augment GNSS in a kinematic urban environment

    NASA Astrophysics Data System (ADS)

    Bonenberg, L. K.; Roberts, G. W.; Hancock, C. M.

    2011-12-01

    GNSS has become one of the most widespread measurement technologies, widely used in GIS, mobile mapping applications and civil engineering. Utilisation of differential techniques offers cm-level positioning accuracy. Identified drawbacks are the requirement for line of sight to the satellites and accuracy dependent on the geometric distribution of the satellites. Especially the latter is paramount for any surveying or mobile mapping application in the urban environment. The utilisation of additional constellations (GLONASS, GALILEO or COMPASS) only partly mitigates the problem. Locata is an Australian terrestrial positioning technology, based on the pseudolite concept. It's unique in its utilisation of the 2.4GHz ISM band and proprietary TimeLoc procedure, allowing for network synchronisation at the nanosecond level. This paper focuses on the tight integration of GNSS with Locata, in order to address the described drawbacks and to provide cm level positioning in areas currently "difficult" for GNSS - such as urban canyons. This paper describes the intended deployment and utilisation of the integrated system in the typical urban environment where availability of GPScan be limited or even non-existent, depending on the time and location. The verification of the integration methods has been carried out using simulated GPS and Locata data. Also presented is an application simulation in a typical urban canyon environment (Canary Wharf, London, UK) using proprietary software developed at the University of Nottingham. Simulation of the proposed integration algorithms, using a real life scenario, has shown promising results with centimetre-level positioning accuracy on the moving platform. The algorithm provides code ambiguity estimation for both Locata and GPS on-the-fly, without prior knowledge of the position, providing predominantly 3D position on the cm level.

  9. Mobilising community collectivisation among female sex workers to promote STI service utilisation from the government healthcare system in Andhra Pradesh, India.

    PubMed

    Parimi, Prabhakar; Mishra, Ram Manohar; Tucker, Saroj; Saggurti, Niranjan

    2012-10-01

    To assess the association between female sex workers' (FSWs) degree of community collectivisation and self-efficacy, utilisation of sexually transmitted infection (STI) services from government-run health centres in Andhra Pradesh, India. Cross-sectional analyses of 1986 FSWs recruited using a probability-based sampling from five districts of Andhra Pradesh during 2010-2011. Multiple logistic regression models were constructed to assess associations. The independent variables included-collective efficacy, collective agency and collective action-measured using a series of items that assessed the grouping of the community on issues that concern most sex workers. An additional independent variable included FSWs belonging to an area where there was a project partnership with government health centres to provide STI treatment services to FSWs. The outcome indicators included self-efficacy for service utilisation from government health facilities and the treatment for STIs from government health facilities at least once in the past year experience of STI symptoms. Of the 1986 FSWs, nearly two-fifths (39.5%) reported a high level of overall collectivisation (collective efficacy: 89%, collective agency: 50.7%; collective action: 12.7%). Sex workers with a high degree compared with low degree of overall collectivisation were significantly more likely to report high self-efficacy to use government health facilities (75.0% vs 57.3%, adjusted OR 2.5, 95% CI 2.0 to 3.1) and to use government health centres for STI treatment in past 1 year (78.1% vs 63.2%, adjusted OR 2.1, 95% CI 1.6 to 2.8), irrespective of project partnership with government centres. The current research findings reinforce the need for stronger community mobilisation for better utilisation of government health facilities for STI and HIV prevention interventions.

  10. Accounting for neutron exposure in the Japanese atomic bomb survivors.

    PubMed

    Cullings, Harry M; Pierce, Donald A; Kellerer, Albrecht M

    2014-12-01

    The Japanese atomic bomb survivors that were directly exposed to both γ rays and neutrons have been followed by the Radiation Effects Research Foundation (RERF). The estimation of the γ-ray risks requires some adjustment for the greater biological effect of the neutrons per unit dose. Because the small neutron doses and the predominant γ-ray doses are highly correlated, the neutron relative biological effectiveness (RBE) cannot be reliably estimated from the survivors' data and information from radiobiology must be invoked. As data became available on neutron doses, RERF has used a constant neutron RBE value of 10, even though radiobiological studies indicate that the RBE values appear to have considerably larger values at low doses. The approximation RBE = 10 assumes that if the RBE is variable it takes roughly this value in the range of total dose most relevant for linear risk estimation, namely about 1 Gy. We consider some possible RBE functions to explain the correct use and the impact of a dose-dependent RBE. However, we do not advocate any particular choice or even that a variable RBE be employed. Rather we show that the assumed neutron RBE, within a wide range of choices, is far less important to the outcome of risk assessment of the RERF data than generally believed. Some of these misperceptions have been related to the consideration of variable RBE functions, and without due attention to the fact that in the case of the A-bomb survivors' data, the mixed field of neutrons and γ rays must be considered. Therefore, the RBE value of neutrons is much lower than the RBE in pure neutron fields that are used in radiobiological experiments. Thus, applying the pure neutron field RBE to the mixed-field A-bomb radiation can lead to an overestimation of the actual neutron RBE for moderate total dose levels of 1 Gy by a factor of more than four. While in a pure neutron exposure the RBE depends on the neutron dose, in the mixed field it depends on both components of exposure, and in particular, we show that in the RERF setting the RBE depends mainly on the accompanying γ-ray dose.

  11. Cell survivor: Modeling radiobiological phenomena with a new kind of simulation

    NASA Astrophysics Data System (ADS)

    Spencer, Melissa A.

    Despite widespread societal fear of radiation, whether justified or unjustified, and whether related to medicine (e.g., CT scans) or other forms of nuclear and atomic radiation (e.g., nuclear power) there is a fundamental lack of basic understanding of radiation effects on the human body. Different types of radiation are psychologically grouped into the same general fear category irrespective of their different potential to do harm, and this fear is not balanced by their potential beneficial effects. By modeling certain types of radiation biology experiments within a game engine, it is possible to enhance the player's intuitive understanding of radiobiology, both the effects of different types of radiation as well as different environmental factors that can enhance or suppress repair. For this dissertation, a game/simulation has been developed that intends to narrow the gap between public perception and the reality of these physical processes. The building blocks of this simulation are cells, which are damaged by incident radiation, accumulating either single or double strand breaks. They grow and reproduce, and are especially vulnerable during certain phases of the cell cycle (e.g. mitosis). Two dominant damage mechanisms are modeled, along with multiple repair mechanisms, for example, double strand breaks can be repaired by either non-homologous end joining or homologous repair. The output of the developed simulation was compared to data collected in experimental studies and the simulation appears to be a valid representation of the dominant mechanisms of radiobiology, as far as can be determined within the scope of this dissertation. Cell survival curves generated from playtest data display shoulders that depend on the LET of incident radiation, and rest time restores repair capability. In addition to public outreach, the presented code can be used to aid investigators by collecting data during play that can be used as a distributed Monte Carlo simulation, aggregating the results of many different runs of the same level and comparing them to theory. Cell Survivor shows promise as both an educational tool and a research tool, depending on the interest of the user.

  12. Successful Teaching of Radiobiology Students in the Medical Management of Acute Radiation Effects From Real Case Histories Using Clinical Signs and Symptoms and Taking Advantage of Recently Developed Software Tools.

    PubMed

    Majewski, Matthäus; Combs, Stephanie E; Trott, Klaus-Rüdiger; Abend, Michael; Port, Matthias

    2018-07-01

    In 2015, the Bundeswehr Institute of Radiobiology organized a North Atlantic Treaty Organization exercise to examine the significance of clinical signs and symptoms for the prediction of late-occurring acute radiation syndrome. Cases were generated using either the Medical Treatment Protocols for Radiation Accident Victims (METREPOL, n = 167) system or using real-case descriptions extracted from a database system for evaluation and archiving of radiation accidents based on case histories (SEARCH, n = 24). The cases ranged from unexposed [response category 0 (RC 0, n = 89)] to mild (RC 1, n = 45), moderate (RC 2, n = 19), severe (RC 3, n = 20), and lethal (RC 4, n = 18) acute radiation syndrome. During the previous exercise, expert teams successfully predicted hematological acute radiation syndrome severity, determined whether hospitalization was required, and gave treatment recommendations, taking advantage of different software tools developed by the North Atlantic Treaty Organization teams. The authors provided the same data set to radiobiology students who were introduced to the medical management of acute effects after radiation exposure and the software tools during a class lasting 15 h. Corresponding to the previous results, difficulties in the discrimination between RC 0/RC 1 and RC 3/RC 4, as well as a systematic underestimation of RC 1 and RC 2, were observed. Nevertheless, after merging reported response categories into clinically relevant groups (RC 0-1, RC 2-3, and RC 3-4), it was found that the majority of cases (95.2% ± 2.2 standard deviations) were correctly identified and that 94.7% (±2.6 standard deviations) developing acute radiation syndrome and z96.4% (±1.6 standard deviations) requiring hospitalization were identified correctly. Two out of three student teams also provided a dose estimate. These results are comparable to the best-performing team of the 2015 North Atlantic Treaty Organization exercise (response category: 92.5%; acute radiation syndrome: 95.8%; hospitalization: 96.3%).

  13. Prostate volumetric‐modulated arc therapy: dosimetry and radiobiological model variation between the single‐arc and double‐arc technique

    PubMed Central

    Jiang, Runqing

    2013-01-01

    This study investigates the dosimetry and radiobiological model variation when a second photon arc was added to prostate volumetric‐modulated arc therapy (VMAT) using the single‐arc technique. Dosimetry and radiobiological model comparison between the single‐arc and double‐arc prostate VMAT plans were performed on five patients with prostate volumes ranging from 29−68.1 cm3. The prescription dose was 78 Gy/39 fractions and the photon beam energy was 6 MV. Dose‐volume histogram, mean and maximum dose of targets (planning and clinical target volume) and normal tissues (rectum, bladder and femoral heads), dose‐volume criteria in the treatment plan (D99% of PTV; D30%,D50%,V17Gy and V35Gy of rectum and bladder; D5% of femoral heads), and dose profiles along the vertical and horizontal axis crossing the isocenter were determined using the single‐arc and double‐arc VMAT technique. For comparison, the monitor unit based on the RapidArc delivery method, prostate tumor control probability (TCP), and rectal normal tissue complication probability (NTCP) based on the Lyman‐Burman‐Kutcher algorithm were calculated. It was found that though the double‐arc technique required almost double the treatment time than the single‐arc, the double‐arc plan provided a better rectal and bladder dose‐volume criteria by shifting the delivered dose in the patient from the anterior–posterior direction to the lateral. As the femoral head was less radiosensitive than the rectum and bladder, the double‐arc technique resulted in a prostate VMAT plan with better prostate coverage and rectal dose‐volume criteria compared to the single‐arc. The prostate TCP of the double‐arc plan was found slightly increased (0.16%) compared to the single‐arc. Therefore, when the rectal dose‐volume criteria are very difficult to achieve in a single‐arc prostate VMAT plan, it is worthwhile to consider the double‐arc technique. PACS number: 87.55.D‐, 87.55.dk, 87.55.K‐, 87.55.Qr

  14. Nutrient utilisation and particulate organic matter changes during summer in the upper mixed layer (Ross Sea, Antarctica)

    NASA Astrophysics Data System (ADS)

    Catalano, G.; Povero, P.; Fabiano, M.; Benedetti, F.; Goffart, A.

    1997-01-01

    The relationships among vertical stability, estimated nutrient utilisation and particulate organic matter in the Ross Sea are analysed from data collected during two cruises in the summers of 1987-1988 and 1989-1990. In the upper mixed layer (UML), identified through the vertical stability E( Z(UML)), nutrient consumption is calculated as the difference between the "diluted" nutrient value and the mean calculated from the integrated value in the UML. The nutrient utilisation ratio and E( Z(UML)) are linearly related for E( Z(UML))≤25, whereas for values > 25, the distribution pattern is more scattered and independent of E( Z(UML)). For E( Z(UML))≥25, utilisation values were ≥4, 0.4 and 10 mmol m -3 for nitrate, phosphate and silicate, respectively. Significant relationships between nutrient depletion and both particulate organic carbon (POC) and particulate protein/particulate carbohydrate ratios (PPRT/PCHO) are found. The analysis of particulate matter distribution vs nutrient utilisation shows that the stations could be divided into two groups having different characteristics. The first group includes coastal stations, where high nutrient utilisation, POC and PPRT/PCHO are typical of areas with high production. In the second group (pelagic stations), nutrient utilisation, POC and PPRT/PCHO are lower. The vertical stability can be used to discriminate among the factors that influence primary production.

  15. Social determinants of dental health services utilisation of Greek adults.

    PubMed

    Pavi, E; Karampli, E; Zavras, D; Dardavesis, T; Kyriopoulos, J

    2010-09-01

    To identify the determinants of dental care utilisation among Greek adults, with a particular emphasis on socio-economic determinants. Data were collected through a national survey on health and health care services utilisation of a sample of 4,003 Greek adults stratified by geographic region, age and gender. A purpose made questionnaire was used during face-to-face interviews. A 2-stage model was developed to assess the impact of independent variables on dental utilisation likelihood and frequency. 39.6% (1,562) of Greek adults reported having visited a dentist within the last year. Among dental attenders, 32.6% reported prevention as the reason for visit. Statistically significant differences in dental care utilisation were observed in relation to demographic, socioeconomic and lifestyle factors. Logistic regression analysis showed that gender, age, income, education, place of residence, private insurance coverage and self-rated oral health are important determinants of dental services utilisation. Mean number of dental visits within previous year was 1.6. Results from Poisson regression analysis indicated that lower income level correlates to lower number of dental visits, while having visited for treatment (rather than for prevention) correlated to higher number of dental visits. Greek adults do not exhibit satisfactory dental visiting behaviour. Extent of care sought is associated with need for treatment rather than preventive reasons. The findings confirm the existence of socioeconomic inequalities in dental services utilisation among Greek adults.

  16. Utilization of physiotherapy in the continuum of stroke care at a tertiary hospital in Ibadan, Nigeria.

    PubMed

    Olaleye, Olubukola Adebisi; Lawal, Zainab Iyabo

    2017-03-01

    To investigate the pattern of referral for and utilisation of physiotherapy in the continuum of stroke care at a tertiary hospital in Ibadan, Nigeria. Referral notes and medical records of patients admitted in the University College Hospital, Ibadan with a clinical diagnosis of stroke between January, 2009 and December, 2013 were retrospectively reviewed. Information on age, sex, type of stroke, length of hospital stay, referral for physiotherapy and utilisation of physiotherapy were retrieved. Data were summarised using descriptive statistics and analysed using Chi-square test. A total of 783 patients with stroke were admitted in the hospital during the period under study. The in-patient mortality rate was 37.2%. The mean Length of Hospital Stay (LoHS) was 16.17±12.34 days. Referral rate for physiotherapy was high (75.8%) and the mean time from admission to referral for physiotherapy was three days. Majority of patients referred utilised physiotherapy (63.4%) and mean number of physiotherapy sessions received during in-patient care was 8.69±6.45. There was a significant association between LoHS and utilisation of in-patientphysiotherapy (p=0.02). The referral rate of stroke patients for physiotherapy was relatively high. Utilisation of in-patient physiotherapy reduced length of hospital stay among patients with stroke. Utilisation of out-patient physiotherapy was low. Strategies to enhance out-patient utilisation should be explored.

  17. Monitoring Bullying Behaviours May Not Enhance Principal's Awareness of the Prevalence

    ERIC Educational Resources Information Center

    Fröjd, Sari; Saaristo, Vesa; Ståhl, Timo

    2014-01-01

    Monitoring bullying behaviours is the key aspect of a successful anti-bullying intervention. Questionnaires among pupils and principals of the same schools were utilised to measure the agreement between pupil-reported frequency and principals' estimations of the prevalence of frequent bullying in the same schools and to identify monitoring methods…

  18. Advances in Bio-Tactile Sensors for Minimally Invasive Surgery Using the Fibre Bragg Grating Force Sensor Technique:A Survey

    PubMed Central

    Abushagur, Abdulfatah A.G.; Arsad, Norhana; Ibne Reaz, Mamun; Ashrif, A.; Bakar, A.

    2014-01-01

    The large interest in utilising fibre Bragg grating (FBG) strain sensors for minimally invasive surgery (MIS) applications to replace conventional electrical tactile sensors has grown in the past few years. FBG strain sensors offer the advantages of optical fibre sensors, such as high sensitivity, immunity to electromagnetic noise, electrical passivity and chemical inertness, but are not limited by phase discontinuity or intensity fluctuations. FBG sensors feature a wavelength-encoding sensing signal that enables distributed sensing that utilises fewer connections. In addition, their flexibility and lightness allow easy insertion into needles and catheters, thus enabling localised measurements inside tissues and blood. Two types of FBG tactile sensors have been emphasised in the literature: single-point and array FBG tactile sensors. This paper describes the current design, development and research of the optical fibre tactile techniques that are based on FBGs to enhance the performance of MIS procedures in general. Providing MIS or microsurgery surgeons with accurate and precise measurements and control of the contact forces during tissues manipulation will benefit both surgeons and patients. PMID:24721774

  19. Short communication: timeline of radiation-induced kidney function loss after stereotactic ablative body radiotherapy of renal cell carcinoma as evaluated by serial (99m)Tc-DMSA SPECT/CT.

    PubMed

    Jackson, Price; Foroudi, Farshad; Pham, Daniel; Hofman, Michael S; Hardcastle, Nicholas; Callahan, Jason; Kron, Tomas; Siva, Shankar

    2014-11-26

    Stereotactic ablative body radiotherapy (SABR) has been proposed as a definitive treatment for patients with inoperable primary renal cell carcinoma. However, there is little documentation detailing the radiobiological effects of hypofractionated radiation on healthy renal tissue. In this study we describe a methodology for assessment of regional change in renal function in response to single fraction SABR of 26 Gy. In a patient with a solitary kidney, detailed follow-up of kidney function post-treatment was determined through 3-dimensional SPECT/CT imaging and (51)Cr-EDTA measurements. Based on measurements of glomerular filtration rate, renal function declined rapidly by 34% at 3 months, plateaued at 43% loss at 12 months, with minimal further decrease to 49% of baseline by 18 months. The pattern of renal functional change in (99m)Tc-DMSA uptake on SPECT/CT imaging correlates with dose delivered. This study demonstrates a dose effect relationship of SABR with loss of kidney function.

  20. Quantifying radionuclide signatures from a γ-γ coincidence system.

    PubMed

    Britton, Richard; Jackson, Mark J; Davies, Ashley V

    2015-11-01

    A method for quantifying gamma coincidence signatures has been developed, and tested in conjunction with a high-efficiency multi-detector system to quickly identify trace amounts of radioactive material. The γ-γ system utilises fully digital electronics and list-mode acquisition to time-stamp each event, allowing coincidence matrices to be easily produced alongside typical 'singles' spectra. To quantify the coincidence signatures a software package has been developed to calculate efficiency and cascade summing corrected branching ratios. This utilises ENSDF records as an input, and can be fully automated, allowing the user to quickly and easily create/update a coincidence library that contains all possible γ and conversion electron cascades, associated cascade emission probabilities, and true-coincidence summing corrected γ cascade detection probabilities. It is also fully searchable by energy, nuclide, coincidence pair, γ multiplicity, cascade probability and half-life of the cascade. The probabilities calculated were tested using measurements performed on the γ-γ system, and found to provide accurate results for the nuclides investigated. Given the flexibility of the method, (it only relies on evaluated nuclear data, and accurate efficiency characterisations), the software can now be utilised for a variety of systems, quickly and easily calculating coincidence signature probabilities. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  1. A systematic review of the literature exploring illness perceptions in mental health utilising the self-regulation model.

    PubMed

    Baines, Tineke; Wittkowski, Anja

    2013-09-01

    Psychologists have utilised a range of social cognition models to understand variation in physical health and illness-related behaviours. The most widely studied model of illness perceptions has been the Self-Regulation Model (SRM, Leventhal, Nerenz, & Steele, 1984). The illness perceptions questionnaire (IPQ) and its revised version (IPQ-R) have been utilised to explore illness beliefs in physical health. This review examined 13 quantitative studies, which used the IPQ and IPQ-R in mental health in their exploration of illness perceptions in psychosis, bipolar disorder, eating disorders, depression and adolescents experiencing mood disorders. Across these studies the SRM illness dimensions were largely supported. Mental illnesses were commonly viewed as cyclical and chronic, with serious negative consequences. Perceptions regarding chronicity, controllability and negative consequences were associated with coping and help seeking, while engagement with services and help seeking were also related to illness coherence beliefs. Treatment adherence was linked to beliefs that treatment could control one's illness. Whilst a major limitation of the reviewed studies was the use of cross-sectional designs, overall the applicability of the SRM to mental health was supported. The IPQ and IPQ-R were shown to be valuable measures of illness perceptions in mental health, offering implications for clinical practice.

  2. Dynamic output feedback control of a flexible air-breathing hypersonic vehicle via T-S fuzzy approach

    NASA Astrophysics Data System (ADS)

    Hu, Xiaoxiang; Wu, Ligang; Hu, Changhua; Wang, Zhaoqiang; Gao, Huijun

    2014-08-01

    By utilising Takagi-Sugeno (T-S) fuzzy set approach, this paper addresses the robust H∞ dynamic output feedback control for the non-linear longitudinal model of flexible air-breathing hypersonic vehicles (FAHVs). The flight control of FAHVs is highly challenging due to the unique dynamic characteristics, and the intricate couplings between the engine and fight dynamics and external disturbance. Because of the dynamics' enormous complexity, currently, only the longitudinal dynamics models of FAHVs have been used for controller design. In this work, T-S fuzzy modelling technique is utilised to approach the non-linear dynamics of FAHVs, then a fuzzy model is developed for the output tracking problem of FAHVs. The fuzzy model contains parameter uncertainties and disturbance, which can approach the non-linear dynamics of FAHVs more exactly. The flexible models of FAHVs are difficult to measure because of the complex dynamics and the strong couplings, thus a full-order dynamic output feedback controller is designed for the fuzzy model. A robust H∞ controller is designed for the obtained closed-loop system. By utilising the Lyapunov functional approach, sufficient solvability conditions for such controllers are established in terms of linear matrix inequalities. Finally, the effectiveness of the proposed T-S fuzzy dynamic output feedback control method is demonstrated by numerical simulations.

  3. Estimation of the growth kinetics for the cooling crystallisation of paracetamol and ethanol solutions

    NASA Astrophysics Data System (ADS)

    Mitchell, Niall A.; Ó'Ciardhá, Clifford T.; Frawley, Patrick J.

    2011-08-01

    This work details the estimation of the growth kinetics of paracetamol in ethanol solutions for cooling crystallisation processes, by means of isothermal seeded batch experiments. The growth kinetics of paracetamol crystals were evaluated in isolation, with the growth rate assumed to be size independent. Prior knowledge of the Metastable Zone Width (MSZW) was required, so that supersaturation ratios of 1.7-1.1 could be induced in solution without the occurrence of nucleation. The technique involved the utilisation of two in-situ Process Analytical Techniques (PATs), with a Focused Beam Reflectance Measurement (FBRM ®) utilised to ensure that negligible nucleation occurred and an Attenuated Total Reflectance-Fourier Transform Infrared (ATR-FTIR) probe employed for online monitoring of solute concentration. Initial Particle Size Distributions (PSDs) were used in conjunction with desupersaturation profiles to determine the growth rate as a function of temperature and supersaturation. Furthermore, the effects of seed loading and size on the crystal growth rate were investigated. A numerical model, incorporating the population balance equation and the method of moments, was utilised to describe the crystal growth process. Experimental parameters were compared to the model simulation, with the accuracy of the model validated by means of the final product PSDs and solute concentration.

  4. The utilisation of two detectors for the determination of water in honey using headspace gas chromatography.

    PubMed

    Frink, Lillian A; Armstrong, Daniel W

    2016-08-15

    A headspace gas chromatography (HSGC) method was developed for the determination of water content in honey. This method was shown to work with five different honey varieties which had a range of water from 14-16%. It also utilised two different detectors, the thermal conductivity detector (TCD) and the barrier discharge ionisation detector (BID). This method needs no heating pretreatment step as in the current leading method, (i.e. the measurement of refractive index). The solvent-free procedure negates the possibility of solvent-compound interactions as well as solubility limitations, as is common with Karl Fischer titrations. It was also apparent that the classic loss on drying method consistently and substantially produced results that were lower than the correct values. This approach is shown to be rapid, with an analysis time of 4 min when using the TCD detector and under 3 min when utilising the BID detector. HSGC is feasible for the determination of water due to the new PEG-linked geminal dicationic ionic-liquid-coated GC capillary column. In addition it provides accurate and precise determinations of the water content in honey. When using the sensitive BID detector, other trace volatile compounds are observed as well. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Effect of dietary calcium level and source on mineral utilisation by piglets fed diets containing exogenous phytase.

    PubMed

    Schlegel, P; Gutzwiller, A

    2017-10-01

    Calcium and phosphorus are essential minerals, closely linked in digestive processes and metabolism. With widespread use of low P diets containing exogenous phytase, the optimal dietary Ca level was verified. The 40-day study evaluated the effects of Ca level (4, 7 and 10 g/kg diet) and Ca source (Ca from CaCO 3 and from Lithothamnium calcareum) on mineral utilisation in 72 piglets (7.9 ± 1.0 kg BW) fed an exogenous phytase containing diet with 2.9 g digestible P/kg. Measured parameters were growth performance, stomach mineral solubility, bone breaking strength and urinary, serum and bone mineral concentration. The apparent total tract digestibility of minerals was also assessed in the two diets with 7 g Ca/kg, using 12 additional pigs. Regardless of Ca source, increasing dietary Ca impaired feed conversion ratio, increased urinary pH, increased serum and urinary Ca, decreased serum and urinary P, decreased serum Mg and increased urinary Mg, increased serum AP activity, decreased bone Mg increased bone Zn. Bone breaking strength was improved with 7 compared to 4 g Ca/kg. Compared to CaCO 3 , Ca from Lithothamnium calcareum increased serum Mg and with, 10 g Ca/kg, it limited body weight gain. The dose response of Ca in a diet with 2.9 g digestible P/kg and including exogenous phytase indicated that: (i) a low dietary Ca was beneficial for piglet growth, but was limiting the metabolic use of P; (ii) a high dietary Ca level impaired P utilisation; (iii) the optimal P utilisation and bone breaking strength was obtained with a dietary Ca-to-digestible P ratio of 2.1 to 2.4:1; (iv). Increasing dietary Ca reduced Mg utilisation, but not Zn status, when fed at adequate level. Finally, Ca from Lithothamnium calcareum had similar effects on Ca and P metabolism as CaCO 3 , but impaired growth when fed at the highest inclusion level. Journal of Animal Physiology and Animal Nutrition © 2016 Blackwell Verlag GmbH.

  6. Spanish nurses' attitudes towards research and perceived barriers and facilitators of research utilisation: a comparative survey of nurses with and without experience as principal investigators.

    PubMed

    Moreno-Casbas, Teresa; Fuentelsaz-Gallego, Carmen; de Miguel, Angel Gil; González-María, Esther; Clarke, Sean P

    2011-07-01

    To examine attitudes towards research and perceived barriers and facilitators of research utilisation in clinical practice in a broad cross-section of Spanish nurses. Nurses' attitudes towards research are critical in determining whether study findings are used to improve practice. Cross-sectional comparative survey in Hospitals, Primary Care Centres and University-affiliated schools of nursing. Surveys were completed by 917 nurses: 69 who received funding from the Spanish national agency (1998-2004) and a nationally representative sample of 848 nurses who did not have the same research experience (the Comparison group). Two instruments (BARRIERS and Attitudes towards nursing research) were translated and culturally adapted for use in Spain. A descriptive analysis of demographic and practice characteristics was performed. Total scale scores, as well as subscale scores, were computed and compared across the two groups using one-way analysis of variance (anova) and multivariate analysis of variance (manova) with post hoc tests. Pearson product-moment correlation coefficients were computed between the total tool scores and subscales measuring barriers and attitudes in both groups. The investigators differed from other nurses on several demographic and work characteristics (more males, older age and more likely to work a fixed day shift schedule). On the whole, investigators showed more favourable attitudes but perceived several elements as posing greater barriers to research utilisation than the Comparison groups. Across all respondents, issues related to the quality of research were rated as the greatest barriers to research utilisation, followed by organisational barriers, barriers involving the communication of findings and finally, those related to nurses' values, awareness and skills. Very similar profiles of perceptions and attitudes regarding research were found in these samples of Spanish nurses relative to those from other countries in earlier reports. Nurses who had experience conducting research demonstrated more favourable research-related attitudes and perceived barriers differently than those without such experience. Understanding different organisational and experience perspectives is important to identify challenges and opportunities to ensure research utilisation in clinical practice. © 2011 Blackwell Publishing Ltd.

  7. Factors associated with postnatal care utilisation in Rwanda: A secondary analysis of 2010 Demographic and Health Survey data.

    PubMed

    Rwabufigiri, Bernard N; Mukamurigo, Judith; Thomson, Dana R; Hedt-Gautier, Bethany L; Semasaka, Jean Paul S

    2016-05-31

    Postnatal care (PNC) in the first seven days is important for preventing morbidity and mortality in mothers and new-borns. Sub-Saharan African countries, which account for 62 % of maternal deaths globally, have made major efforts to increase PNC utilisation, but utilisation rates remains low even in countries like Rwanda where PNC services are universally available for free. This study identifies key socio-economic and demographic factors associated with PNC utilisation in Rwanda to inform improved PNC policies and programs. This is a secondary analysis of the 2010 Demographic and Health Survey, a national multi-stage, cross-sectional survey. In bivariate analysis, we used chi-square tests to identify demographic and socio-economic factors associated with PNC utilisation at α = 0.1. Pearson's R statistic (r > 0.5) was used to identify collinear covariates, and to choose which covariate was more strongly associated with PNC utilisation. Manual backward stepwise logistic regression was performed on the remaining covariates to identify key factors associated with PNC utilisation at α = 0.05. All analyses were performed in Stata 13 adjusting for sampling weights, clustering, and stratification. Of the 2,748 women with a live birth in the last two years who answered question about PNC utilisation, 353 (12.8 %) returned for PNC services within seven days after birth. Three factors were positively associated with PNC use: delivering at a health facility (OR: 2.97; 95 % CI: 2.28-3.87), being married but not involved with one's own health care decision-making (OR: 1.69; 95 % CI: 1.17, 2.44) compared to being married and involved; and being in the second (OR: 1.46; 95 % CI: 1.01-2.09) or richest wealth quintile (OR: 2.04; 95 % CI: 1.27-3.29) compared to the poorest. Mother's older age at delivery was negatively associated with PNC use (20-29 - OR: 0.51, 95 % CI: 0.29-0.87; 30-39 - OR: 0.47, 95 % CI: 0.27-0.83; 40-49 - OR: 0.32, 95 % CI: 0.16-0.64). Low PNC utilisation in Rwanda appears to be a universal problem though older age and poverty are further barriers to PNC utilisation. A recent change in the provision of BCG vaccination to new-borns might promote widespread PNC utilisation. We further recommend targeted campaigns to older mothers and poorest mothers, focusing on perceptions of health system quality, cultural beliefs, and pregnancy risks.

  8. Contextual and individual factors associated with dental services utilisation by Brazilian adults: A multilevel analysis

    PubMed Central

    2018-01-01

    Background Inequalities in the utilisation of dental services in Brazil are remarkable. The aim of this study was to evaluate the association of contextual and individual factors with the utilisation of dental services by Brazilian adults using the Andersen’s behavioural model. Methods Individual-level data from 27,017 adults residents in the State capitals who were interviewed in the 2013 Brazilian National Health Survey were pooled with contextual city-level data. The outcomes were non-utilisation of dental services and last dental visit over 12 months ago. Individual predisposing variables were age, sex, race/skin colour, schooling and social network. Individual enabling variables included income, health insurance and registration in primary health care. Individual need variables were self-perceived dental health and self-reported missing teeth. Multilevel logistic regression models were performed to estimate odds ratio (OR) and 95% confidence intervals (95% CIs) of the association of contextual and individual predisposing, enabling and need-related variables with dental services outcomes. Results Predisposing (OR = 0.89; 95% CI 0.81–0.97) and enabling (OR = 0.90; 95% CI 0.85–0.96) contextual factors were associated with non-utilisation of dental services. Individual predisposing (sex, race/skin colour, schooling), enabling (income, health insurance) and need (self-perceived oral health, missing teeth) were associated with non-utilisation of dental services and last dental visit over 12 months ago. The latter was also associated with other individual predisposing (age, social network) and need (eating difficulties due to oral problems) characteristics. Conclusions Individual and contextual determinants influenced dental services utilisation in Brazilian adults. These factors should be on the policy agenda and considered in the organisation of health services aiming to reduce oral health inequalities related to access and utilisation of dental services. PMID:29420660

  9. Contextual and individual factors associated with dental services utilisation by Brazilian adults: A multilevel analysis.

    PubMed

    Herkrath, Fernando José; Vettore, Mario Vianna; Werneck, Guilherme Loureiro

    2018-01-01

    Inequalities in the utilisation of dental services in Brazil are remarkable. The aim of this study was to evaluate the association of contextual and individual factors with the utilisation of dental services by Brazilian adults using the Andersen's behavioural model. Individual-level data from 27,017 adults residents in the State capitals who were interviewed in the 2013 Brazilian National Health Survey were pooled with contextual city-level data. The outcomes were non-utilisation of dental services and last dental visit over 12 months ago. Individual predisposing variables were age, sex, race/skin colour, schooling and social network. Individual enabling variables included income, health insurance and registration in primary health care. Individual need variables were self-perceived dental health and self-reported missing teeth. Multilevel logistic regression models were performed to estimate odds ratio (OR) and 95% confidence intervals (95% CIs) of the association of contextual and individual predisposing, enabling and need-related variables with dental services outcomes. Predisposing (OR = 0.89; 95% CI 0.81-0.97) and enabling (OR = 0.90; 95% CI 0.85-0.96) contextual factors were associated with non-utilisation of dental services. Individual predisposing (sex, race/skin colour, schooling), enabling (income, health insurance) and need (self-perceived oral health, missing teeth) were associated with non-utilisation of dental services and last dental visit over 12 months ago. The latter was also associated with other individual predisposing (age, social network) and need (eating difficulties due to oral problems) characteristics. Individual and contextual determinants influenced dental services utilisation in Brazilian adults. These factors should be on the policy agenda and considered in the organisation of health services aiming to reduce oral health inequalities related to access and utilisation of dental services.

  10. Development of nanostructured PVD coatings for total knee replacement joints using HIPIMS

    NASA Astrophysics Data System (ADS)

    Sugumaran, Arunprabhu A.

    The aim of this study was to develop thin film coatings for total knee replacement joints using high power impulse magnetron sputtering (HIPIMS). An industrial size four cathode magnetron sputtering system equipped with direct current (DC) and HIPIMS power supplies was used for this purpose. Initially, Plasma diagnostics were carried out using optical emission spectroscopy (OES) while sputtering Ti target in Ar + N2 atmosphere by utilizing various HIP IMS/conventional DCMS (henceforth UBM) source combinations by varying the process parameters such as coil current and N2 flow. Then, single layer titanium nitride (TiN) coating was deposited by varying the degree of HIPIMS utilisation and the process parameters such as bias voltage and coil current to thoroughly understand the effect of degree of HIPIMS utilisation on the microstructure, residual stress, texture, mechanical, tribological and corrosion properties of such coatings. The degree of HIPIMS utilisation was altered by increasing the number of HIPIMS targets used for the deposition. Four different source combinations were used for this purpose, as follows: 4 cathodes in conventional DCMS mode to deposit pure UBM coating, 1 HIPIMS + 3UBM and 2HIPIMS + 2UBM cathodes to deposit combined HIPIMS/UBM coatings and 2HIPIMS cathodes to deposit pure HIPIMS coatings. TiN/NbN, TiCN/NbCN and CrN/NbN multilayer coatings were deposited on CoCr alloy test buttons along with other (HSS, SS and Si) substrates since our intended application is on total knee replacement joints made of CoCr alloy. The knowledge gained by investigating the TiN (Ar + N[2]) plasma and the properties of TiN was used to determine the process parameters for depositing the multilayer coatings. X- ray diffraction (XRD) technique was used for calculating the texture, residual stress and bilayer thickness of the coatings. Nanoindentation method was used to determine the nano hardness of the coatings. The adhesion strength of the coatings was estimated by scratch and Rockwell indentation tests. Pin on disc method was used for the tribological studies such as coefficient of friction and coefficient of wear. Surface roughness measurements were carried out using a surface profiler. Microstructural characterisation of the coatings was carried out using scanning electron microscope (SEM) and transmission electron microscope (TEM). Potentiodynamic polarisation method was utilised to study the corrosion performance of the coatings. Raman spectroscopy was used to study the constituents of the corrosion products and evaluate the corrosion damage. OES measurements revealed that the degree of metal ions (Ti[1+]) increased with increasing degree of HIPIMS utilisation. The hardness, tribological and corrosion properties of TiN coatings improved with increasing degree of HIPIMS utilisation. TiN and multilayer coatings deposited by HIPIMS exhibited a smooth columnar microstructure without any voided region along the column boundaries. TiN/NbN, TiCN/NbCN and CrN/NbN multilayer coatings deposited on CoCr alloy, HSS and SS test buttons exhibited superior mechanical, tribological and corrosion properties as compared to the underlying substrate.

  11. Utilisation of joint movement range in arboreal primates compared with human subjects: an evolutionary frame for primary osteoarthritis.

    PubMed Central

    Alexander, C J

    1994-01-01

    OBJECTIVE--To determine whether an arboreal lifestyle required full use of movement ranges underutilised in nine joint groups in humans, because under-utilisation of available movement range may be associated with susceptibility to primary osteoarthritis. METHODS--Utilisation of the nine joint groups was studied in two species of primate exercising in a simulated arboreal environment, using 'focal animal' observation techniques supplemented by telephoto photography and by review of archival material from other sources. Fifteen apes were observed over a total observation period of 20.2 man-hours and 152 films were analysed for utilisation of movement range. RESULTS--With one exception, all the movement ranges reported to be under-utilised in humans were fully utilised by the apes in climbing activities. The exception, metacarpophalangeal extension, was an essential component of the chimpanzee ground progression mode of knuckle walking. CONCLUSIONS--The underused movement range in several human joints is explicable as residual capacity from a semiarboreal lifestyle. If the correlation with primary osteoarthritis is confirmed, it suggests that the disease may reflect a disparity between inherited capacity and current need. The significance of the result lies in its implication that primary osteoarthritis may be preventable. Images PMID:7826133

  12. Utilisation of joint movement range in arboreal primates compared with human subjects: an evolutionary frame for primary osteoarthritis.

    PubMed

    Alexander, C J

    1994-11-01

    To determine whether an arboreal lifestyle required full use of movement ranges underutilised in nine joint groups in humans, because under-utilisation of available movement range may be associated with susceptibility to primary osteoarthritis. Utilisation of the nine joint groups was studied in two species of primate exercising in a simulated arboreal environment, using 'focal animal' observation techniques supplemented by telephoto photography and by review of archival material from other sources. Fifteen apes were observed over a total observation period of 20.2 man-hours and 152 films were analysed for utilisation of movement range. With one exception, all the movement ranges reported to be under-utilised in humans were fully utilised by the apes in climbing activities. The exception, metacarpophalangeal extension, was an essential component of the chimpanzee ground progression mode of knuckle walking. The underused movement range in several human joints is explicable as residual capacity from a semiarboreal lifestyle. If the correlation with primary osteoarthritis is confirmed, it suggests that the disease may reflect a disparity between inherited capacity and current need. The significance of the result lies in its implication that primary osteoarthritis may be preventable.

  13. On the modified grain-size-distribution method to evaluate the dynamic recrystallisation fraction in AISI 304 stainless steel

    NASA Astrophysics Data System (ADS)

    Hong, D. H.; Park, J. K.

    2018-04-01

    The purpose of the present work was to verify the grain size distribution (GSD) method, which was recently proposed by one of the present authors as a method for evaluating the fraction of dynamic recrystallisation (DRX) in a microalloyed medium carbon steel. To verify the GSD-method, we have selected a 304 stainless steel as a model system and have measured the evolution of the overall grain size distribution (including both the recrystallised and unrecrystallised grains) during hot compression at 1,000 °C in a Gleeble machine; the DRX fraction estimated using the GSD method is compared with the experimentally measured value via EBSD. The results show that the previous GSD method tends to overestimate the DRX fraction due to the utilisation of a plain lognormal distribution function (LDF). To overcome this shortcoming, we propose a modified GSD-method wherein an area-weighted LDF, in place of a plain LDF, is employed to model the evolution of GSD during hot deformation. Direct measurement of the DRX fraction using EBSD confirms that the modified GSD-method provides a reliable method for evaluating the DRX fraction from the experimentally measured GSDs. Reasonable agreement between the DRX fraction and softening fraction suggests that the Kocks-Mecking method utilising the Voce equation can be satisfactorily used to model the work hardening and dynamic recovery behaviour of steels during hot deformation.

  14. Calibration of GafChromic EBT3 for absorbed dose measurements in 5 MeV proton beam and (60)Co γ-rays.

    PubMed

    Vadrucci, M; Esposito, G; Ronsivalle, C; Cherubini, R; Marracino, F; Montereali, R M; Picardi, L; Piccinini, M; Pimpinella, M; Vincenti, M A; De Angelis, C

    2015-08-01

    To study EBT3 GafChromic film in low-energy protons, and for comparison purposes, in a reference (60)Co beam in order to use it as a calibrated dosimetry system in the proton irradiation facility under construction within the framework of the Oncological Therapy with Protons (TOP)-Intensity Modulated Proton Linear Accelerator for RadioTherapy (IMPLART) Project at ENEA-Frascati, Italy. EBT3 film samples were irradiated at the Istituto Nazionale di Fisica Nucleare-Laboratori Nazionali di Legnaro, Italy, with a 5 MeV proton beam generated by a 7 MV Van de Graaff CN accelerator. The nominal dose rates used were 2.1 Gy/min and 40 Gy/min. The delivered dose was determined by measuring the particle fluence and the energy spectrum in air with silicon surface barrier detector monitors. A preliminary study of the EBT3 film beam quality dependence in low-energy protons was conducted by passively degrading the beam energy. EBT3 films were also irradiated at ENEA-National Institute of Ionizing Radiation Metrology with gamma radiation produced by a (60)Co source characterized by an absorbed dose to water rate of 0.26 Gy/min as measured by a calibrated Farmer type ionization chamber. EBT3 film calibration curves were determined by means of a set of 40 film pieces irradiated to various doses ranging from 0.5 Gy to 30 Gy absorbed dose to water. An EPSON Expression 11000XL color scanner in transmission mode was used for film analysis. Scanner response stability, intrafilm uniformity, and interfilm reproducibility were verified. Optical absorption spectra measurements were performed on unirradiated and irradiated EBT3 films to choose the most sensitive color channel to the dose range used. EBT3 GafChromic films show an under response up to about 33% for low-energy protons with respect to (60)Co gamma radiation, which is consistent with the linear energy transfer dependence already observed with higher energy protons, and a negligible dose-rate dependence in the 2-40 Gy/min range. Short- and long-term scanner stabilities were 0.5% and 1.5%, respectively; film uniformity and reproducibility were better than 0.5%. The main purpose of this study was to implement EBT3 dosimetry in the proton low-energy radiobiology line of the TOP-IMPLART accelerator, having a maximum energy of 7 MeV. Low-energy proton and (60)Co calibrated sources were used to investigate the behavior of film response vs to be written in italicum dose. The calibration in 5 MeV protons is currently used for dose assessment in the radiobiological experiments at the TOP-IMPLART accelerator carried out at that energy value.

  15. Utilising shade to optimize UV exposure for vitamin D

    NASA Astrophysics Data System (ADS)

    Turnbull, D. J.; Parisi, A. V.

    2008-01-01

    Numerous studies have stated that humans need to utilise full sun radiation, at certain times of the day, to assist the body in synthesising the required levels of vitamin D3. The time needed to be spent in the full sun depends on a number of factors, for example, age, skin type, latitude, solar zenith angle. Current Australian guidelines suggest exposure to approximately 1/6 to 1/3 of a minimum erythemal dose (MED), depending on age, would be appropriate to provide adequate vitamin D3 levels. The aim of the study was to determine the exposure times to diffuse solar UV to receive exposures of 1/6 and 1/3 MED for a changing solar zenith angle in order to assess the possible role that diffuse UV (scattered radiation) may play in vitamin D3 effective UV exposures (UVD3). Diffuse and global erythemal UV measurements were conducted at five minute intervals over a twelve month period for a solar zenith angle range of 4° to 80° at a latitude of 27.6° S. For diffuse UV exposures of 1/6 and 1/3 MED, solar zenith angles smaller than 60° and 50° respectively can be utilised for exposure times of less than 10 min. Spectral measurements showed that, for a solar zenith angle of 40°, the UVA (315-400 nm) in the diffuse component of the solar UV is reduced by approximately 62% compared to the UVA in the global UV, whereas UVD3 wavelengths are only reduced by approximately 43%. At certain latitudes, diffuse UV under shade may play an important role in providing the human body with adequate levels of UVD3 (290-330 nm) radiation without experiencing the high levels of damaging UVA observed in full sun.

  16. Utilising shade to optimize UV exposure for vitamin D

    NASA Astrophysics Data System (ADS)

    Turnbull, D. J.; Parisi, A. V.

    2008-06-01

    Numerous studies have stated that humans need to utilise full sun radiation, at certain times of the day, to assist the body in synthesising the required levels of vitamin D3. The time needed to be spent in the full sun depends on a number of factors, for example, age, skin type, latitude, solar zenith angle. Current Australian guidelines suggest exposure to approximately 1/6 to 1/3 of a minimum erythemal dose (MED), depending on age, would be appropriate to provide adequate vitamin D3 levels. The aim of the study was to determine the exposure times to diffuse solar UV to receive exposures of 1/6 and 1/3 MED for a changing solar zenith angle in order to assess the possible role that diffuse UV (scattered radiation) may play in vitamin D3 effective UV exposures (UVD3). Diffuse and global erythemal UV measurements were conducted at five minute intervals over a twelve month period for a solar zenith angle range of 4° to 80° at a latitude of 27.6° S. For a diffuse UV exposure of 1/3 MED, solar zenith angles smaller than approximately 50° can be utilised for exposure times of less than 10 min. Spectral measurements showed that, for a solar zenith angle of 40°, the UVA (315-400 nm) in the diffuse component of the solar UV is reduced by approximately 62% compared to the UVA in the global UV, whereas UVD3 wavelengths are only reduced by approximately 43%. At certain latitudes, diffuse UV under shade may play an important role in providing the human body with adequate levels of UVD3 (290-315 nm) radiation without experiencing the high levels of UVA observed in full sun.

  17. Fasting and exercise increase plasma cannabinoid levels in THC pre-treated rats: an examination of behavioural consequences.

    PubMed

    Wong, Alexander; Keats, Kirily; Rooney, Kieron; Hicks, Callum; Allsop, David J; Arnold, Jonathon C; McGregor, Iain S

    2014-10-01

    Δ(9)-Tetrahydrocannabinol (THC), the main psychoactive constituent of cannabis, accumulates in fat tissue where it can remain for prolonged periods. Under conditions of increased fat utilisation, blood cannabinoid concentrations can increase. However, it is unclear whether this has behavioural consequences. Here, we examined whether rats pre-treated with multiple or single doses of THC followed by a washout would show elevated plasma cannabinoids and altered behaviour following fasting or exercise manipulations designed to increase fat utilisation. Behavioural impairment was measured as an inhibition of spontaneous locomotor activity or a failure to successfully complete a treadmill exercise session. Fat utilisation was indexed by plasma free fatty acid (FFA) levels with plasma concentrations of THC and its terminal metabolite (-)-11-nor-9-carboxy-∆(9)-tetrahydrocannabinol (THC-COOH) also measured. Rats given daily THC (10 mg/kg) for 5 days followed by a 4-day washout showed elevated plasma THC-COOH when fasted for 24 h relative to non-fasted controls. Fasted rats showed lower locomotor activity than controls suggesting a behavioural effect of fat-released THC. However, rats fasted for 20 h after a single 5-mg/kg THC injection did not show locomotor suppression, despite modestly elevated plasma THC-COOH. Rats pre-treated with THC (5 mg/kg) and exercised 20 h later also showed elevated plasma THC-COOH but did not differ from controls in their likelihood of completing 30 min of treadmill exercise. These results confirm that fasting and exercise can increase plasma cannabinoid levels. Behavioural consequences are more clearly observed with pre-treatment regimes involving repeated rather than single THC dosing.

  18. Correlation between carotid bifurcation calcium burden on non-enhanced CT and percentage stenosis, as confirmed by digital subtraction angiography

    PubMed Central

    Sarikaya, B; Lohman, B; Mckinney, A M; Gadani, S; Irfan, M; Lucato, L

    2012-01-01

    Objectives Previous evidence supports a direct relationship between the calcium burden (volume) on post-contrast CT with the percent internal carotid artery (ICA) stenosis at the carotid bifurcation. We sought to further investigate this relationship by comparing non-enhanced CT (NECT) and digital subtraction angiography (DSA). Methods 50 patients (aged 41–82 years) were retrospectively identified who had undergone cervical NECT and DSA. A 64-multidetector array CT (MDCT) scanner was utilised and the images reviewed using preset window widths/levels (30/300) optimised to calcium, with the volumes measured via three-dimensional reconstructive software. Stenosis measurements were performed on DSA and luminal diameter stenoses >40% were considered “significant”. Volume thresholds of 0.01, 0.03, 0.06, 0.09 and 0.12 cm3 were utilised and Pearson'S correlation coefficient (r) was calculated to correlate the calcium volume with percent stenosis. Results Of 100 carotid bifurcations, 88 were available and of these 7 were significantly stenotic. The NECT calcium volume moderately correlated with percent stenosis on DSA r=0.53 (p<0.01). A moderate–strong correlation was found between the square root of calcium volume on NECT with percent stenosis on DSA (r=0.60, p<0.01). Via a receiver operating characteristic curve, 0.06 cm3 was determined to be the best threshold (sensitivity 100%, specificity 90.1%, negative predictive value 100% and positive predictive value 46.7%) for detecting significant stenoses. Conclusion This preliminary investigation confirms a correlation between carotid bifurcation calcium volume and percent ICA stenosis and is promising for the optimal threshold for stenosis detection. Future studies could utilise calcium volumes to create a “score” that could predict high grade stenosis. PMID:21896662

  19. Economic Evaluation of Health Services Costs During Pandemic Influenza A (H1N1) Pdm09 Infection in Pregnant and Non-Pregnant Women in Spain.

    PubMed

    Morales-Suárez-Varela, María; Llopis-González, Agustín; González-Candela, Fernando; Astray, Jenaro; Alonso, Jordi; Garin, Olatz; Castro, Ady; Galan, Juan Carlos; Soldevila, Nuria; Castilla, Jesús; Godoy, Pere; Delgado-Rodríguez, Miguel; Martin, Vicente; Mayoral, Jose María; Pumarola, Tomas; Quintana, José Maria; Tamames, Sonia; Rubio-López, Nuria; Dominguez, Angela

    2016-04-01

    The healthcare and socio-economic burden resulting from influenza A (H1N1) pdm09 in Spain was considerable. Our aim was to estimate and compare the management (resource utilization) and economic healthcare impact in an at-risk group of unvaccinated pregnant women with an unvaccinated group of non-pregnant woman of childbearing age (15-44 yr old). We addressed this question with a longitudinal, observational, multicentre study. Inputs were the requirements in managing both groups of women. Outcome measures were healthcare costs. Direct healthcare (including medical utilisation, prescriptions of antivirals, medication, diagnostic tests, and hospitalisation) costs and indirect (productivity loss) costs were considered. Unit of cost was attributed to the frequency of health service resources utilisation. The mean cost per patient was calculated in this group of women. We found that the influenza clinical pattern was worse in non-pregnant women as they had a high medical risk of 20.4% versus 6.1% of pregnant women. Non-pregnant required more antipyretics and antibiotics, and needed more health service resource utilisation (338 medical visits in non-pregnant women vs. 42 in pregnant women). The total cost of non-pregnant women was higher (€4,689.4/non-pregnant and €2,945.07/pregnant). Cost per (H1N1) pdm09 was lower for pregnant women, probably due to more preventive measures adopted for their protection in Spain. The highest costs were incurred by hospitalisations/day and work absenteeism for non-pregnant than for pregnant women. These data will allow better future pandemic influenza planning.

  20. Economic Evaluation of Health Services Costs During Pandemic Influenza A (H1N1) Pdm09 Infection in Pregnant and Non-Pregnant Women in Spain

    PubMed Central

    MORALES-SUÁREZ-VARELA, María; LLOPIS-GONZÁLEZ, Agustín; GONZÁLEZ-CANDELA, Fernando; ASTRAY, Jenaro; ALONSO, Jordi; GARIN, Olatz; CASTRO, Ady; GALAN, Juan Carlos; SOLDEVILA, Nuria; CASTILLA, Jesús; GODOY, Pere; DELGADO-RODRÍGUEZ, Miguel; MARTIN, Vicente; MAYORAL, Jose María; PUMAROLA, Tomas; QUINTANA, José Maria; TAMAMES, Sonia; RUBIO-LÓPEZ, Nuria; DOMINGUEZ, Angela

    2016-01-01

    Background: The healthcare and socio-economic burden resulting from influenza A (H1N1) pdm09 in Spain was considerable. Our aim was to estimate and compare the management (resource utilization) and economic healthcare impact in an at-risk group of unvaccinated pregnant women with an unvaccinated group of non-pregnant woman of childbearing age (15–44 yr old). Methods: We addressed this question with a longitudinal, observational, multicentre study. Inputs were the requirements in managing both groups of women. Outcome measures were healthcare costs. Direct healthcare (including medical utilisation, prescriptions of antivirals, medication, diagnostic tests, and hospitalisation) costs and indirect (productivity loss) costs were considered. Unit of cost was attributed to the frequency of health service resources utilisation. The mean cost per patient was calculated in this group of women. Results: We found that the influenza clinical pattern was worse in non-pregnant women as they had a high medical risk of 20.4% versus 6.1% of pregnant women. Non-pregnant required more antipyretics and antibiotics, and needed more health service resource utilisation (338 medical visits in non-pregnant women vs. 42 in pregnant women). The total cost of non-pregnant women was higher (€4,689.4/non-pregnant and €2,945.07/pregnant). Conclusions: Cost per (H1N1) pdm09 was lower for pregnant women, probably due to more preventive measures adopted for their protection in Spain. The highest costs were incurred by hospitalisations/day and work absenteeism for non-pregnant than for pregnant women. These data will allow better future pandemic influenza planning. PMID:27252911

  1. Nikolai Fedorovich Gamaliya (1932-2016).

    PubMed

    2016-06-01

    Professor Nikolai Fedorovich Gamaliya, well-known scientist in the field of laser biomedical research, biophysicist, authority in experimental oncology, Laureate of the State Prize in Science and Techno-logy of Ukraine, Head of the Department of Biological Effects of Ionizing and Non-Ionizing Radiation of R.E. Kavetsky Institute of Experimental Pathology, Oncology and Radiobiology of the National Academy of Sciences (NAS) of Ukraine died on June 14, 2016 at the age of 83.

  2. USSR and Eastern Europe Scientific Abstracts, Biomedical and Behavioral Sciences, Number 84

    DTIC Science & Technology

    1977-12-28

    36 Molecular Biology 4° Pharmacology ^2 Physiology • 46 Plant Biochemistry • 5^ Public Health. 56 Radiobiology ->9 Therapy 60...Tyagunenko) USSR UDC 615.332 (Oxycarminomycinum) SYNTHESIS OF II+-OXYCARMINOMYCIN AND STUDY OF ITS ANTINEOPLASTIC ACTIVITY Moscow ANTIBIOTIKI in...antineoplastic activity and toxicity as carminomycin. It suppressed tumor growth by 90% in doses that did not exceed the maximum tolerable (LD10). Figure 1

  3. AFRRI (Armed Forces Radiobiology Research Institute) Annual Research Report, 1 October 1984 through 30 September 1985.

    DTIC Science & Technology

    1985-09-30

    locomotor performance. To evaluate the effects of radiation on social behaviors. To determine how ionizing radiation alters strength and duration of...on social behaviors and the behavioral pharmacology of social behaviors. Study involvement of CNS autostimulation of the immune system of irradiated...marrow cultured in medium not supplemented with the extract. In addition, marrow cultured in media supplemented with various collagen fractions did

  4. Possible directions of refining criteria of radiation safety of spaceflights

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kovalev, Y.Y.; Petrov, V.M.; Sakovich, V.A.

    The possibility of characterizing space flight radiation safety is considered using a value which is integrated over the flight time, takes into account the radiation processes in an irradiated body and averages the probability of adverse radiobiological effects with respect to the distribution of solar proton flares of varying intensity. The proposed characteristic is compared with the current standards with reference to a hypothetic interplanetary flight.

  5. Status and Prospects of Hirfl Experiments on Nuclear Physics

    NASA Astrophysics Data System (ADS)

    Xu, H. S.; Zheng, C.; Xiao, G. Q.; Zhan, W. L.; Zhou, X. H.; Zhang, Y. H.; Sun, Z. Y.; Wang, J. S.; Gan, Z. G.; Huang, W. X.; Ma, X. W.

    HIRFL is an accelerator complex consisting of 3 accelerators, 2 radioactive beams lines, 1 storage rings and a number of experimental setups. The research activities at HIRFL cover the fields of radio-biology, material science, atomic physics, and nuclear physics. This report mainly concentrates on the experiments of nuclear physics with the existing and planned experimental setups such as SHANS, RIBLL1, ETF, CSRe, PISA and HPLUS at HIRFL.

  6. Canine Hematopoiesis in a Model of Combined Injury

    DTIC Science & Technology

    1983-04-29

    AD-P003 869 CANINE HEMATOPOIESIS IN A MODEL OF COMBINED INJURY FHOMAS J. MacVITTIE*, RODNEY L. MONROY*. MITCHELL FINK**, DALE F. GRUBER % MYRA L...radiobiology of acute effects in the canine . The large-animal model is also appropriate for assessing the immunologic, pharmacologic, and surgical modes...of intervention following CI. The canine model of CI at the AFRRI has stressed three developmental aspects: (a) establishing the radio- biology of

  7. Recent and Planned Developments in the CARI Program

    DTIC Science & Technology

    2013-04-01

    software are available from the Radiobiology Research Team Website. The source code is available upon request. CARI-6 is based on the last major... Research Team at its newly founded Civil Aeromedical Research Institute (now called the Civil Aerospace Medical Institute, i.e., CAMI) to investigate...Administration, Office of Aerospace Medicine. Re- port DOT/FAA/AM-11/09, 2011. Online at: www. faa.gov/data_ research / research /med_humanfacs/ oamtechreports

  8. Nuclear reactions induced by high-energy alpha particles

    NASA Technical Reports Server (NTRS)

    Shen, B. S. P.

    1974-01-01

    Experimental and theoretical studies of nuclear reactions induced by high energy protons and heavier ions are included. Fundamental data needed in the shielding, dosimetry, and radiobiology of high energy particles produced by accelerators were generated, along with data on cosmic ray interaction with matter. The mechanism of high energy nucleon-nucleus reactions is also examined, especially for light target nuclei of mass number comparable to that of biological tissue.

  9. The geomagnetically trapped radiation environment: A radiological point of view

    NASA Technical Reports Server (NTRS)

    Holly, F. E.

    1972-01-01

    The regions of naturally occurring, geomagnetically trapped radiation are briefly reviewed in terms of physical parameters such as; particle types, fluxes, spectrums, and spatial distributions. The major emphasis is placed upon a description of this environment in terms of the radiobiologically relevant parameters of absorbed dose and dose-rate and a discussion of the radiological implications in terms of the possible impact on space vehicle design and mission planning.

  10. Microfluidics as a new tool in radiation biology

    PubMed Central

    Lacombe, Jerome; Phillips, Shanna Leslie; Zenhausern, Frederic

    2016-01-01

    Ionizing radiations interact with molecules at the cellular and molecular levels leading to several biochemical modifications that may be responsible for biological effects on tissue or whole organisms. The study of these changes is difficult because of the complexity of the biological response(s) to radiations and the lack of reliable models able to mimic the whole molecular phenomenon and different communications between the various cell networks, from the cell activation to the macroscopic effect at the tissue or organismal level. Microfluidics, the science and technology of systems that can handle small amounts of fluids in confined and controlled environment, has been an emerging field for several years. Some microfluidic devices, even at early stages of development, may already help radiobiological research by proposing new approaches to study cellular, tissue and total-body behavior upon irradiation. These devices may also be used in clinical biodosimetry since microfluidic technology is frequently developed for integrating complex bioassay chemistries into automated user-friendly, reproducible and sensitive analyses. In this review, we discuss the use, numerous advantages, and possible future of microfluidic technology in the field of radiobiology. We will also examine the disadvantages and required improvements for microfluidics to be fully practical in radiation research and to become an enabling tool for radiobiologists and radiation oncologists. PMID:26704304

  11. Microfluidics as a new tool in radiation biology.

    PubMed

    Lacombe, Jerome; Phillips, Shanna Leslie; Zenhausern, Frederic

    2016-02-28

    Ionizing radiations interact with molecules at the cellular and molecular levels leading to several biochemical modifications that may be responsible for biological effects on tissue or whole organisms. The study of these changes is difficult because of the complexity of the biological response(s) to radiations and the lack of reliable models able to mimic the whole molecular phenomenon and different communications between the various cell networks, from the cell activation to the macroscopic effect at the tissue or organismal level. Microfluidics, the science and technology of systems that can handle small amounts of fluids in confined and controlled environment, has been an emerging field for several years. Some microfluidic devices, even at early stages of development, may already help radiobiological research by proposing new approaches to study cellular, tissue and total-body behavior upon irradiation. These devices may also be used in clinical biodosimetry since microfluidic technology is frequently developed for integrating complex bioassay chemistries into automated user-friendly, reproducible and sensitive analyses. In this review, we discuss the use, numerous advantages, and possible future of microfluidic technology in the field of radiobiology. We will also examine the disadvantages and required improvements for microfluidics to be fully practical in radiation research and to become an enabling tool for radiobiologists and radiation oncologists. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  12. Brain necrosis after fractionated radiation therapy: Is the halftime for repair longer than we thought?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bender, Edward T.

    Purpose: To derive a radiobiological model that enables the estimation of brain necrosis and spinal cord myelopathy rates for a variety of fractionation schemes, and to compare repair effects between brain and spinal cord. Methods: Sigmoidal dose response relationships for brain radiation necrosis and spinal cord myelopathy are derived from clinical data using nonlinear regression. Three different repair models are considered and the repair halftimes are included as regression parameters. Results: For radiation necrosis, a repair halftime of 38.1 (range 6.9-76) h is found with monoexponential repair, while for spinal cord myelopathy, a repair halftime of 4.1 (range 0-8) hmore » is found. The best-fit alpha beta ratio is 0.96 (range 0.24-1.73)Conclusions: A radiobiological model that includes repair corrections can describe the clinical data for a variety of fraction sizes, fractionation schedules, and total doses. Modeling suggests a relatively long repair halftime for brain necrosis. This study suggests that the repair halftime for late radiation effects in the brain may be longer than is currently thought. If confirmed in future studies, this may lead to a re-evaluation of radiation fractionation schedules for some CNS diseases, particularly for those diseases where fractionated stereotactic radiation therapy is used.« less

  13. [Radiobiology and the lessons of Chernobyl].

    PubMed

    Baraboĭ, V A

    1990-01-01

    The Chernobyl accident has marked the beginning of a new stage of radiobiology development and revealed scantiness of old concepts. One should (1) search for effective protectors against the long-term influence of low-level radiation and means of removal of radionuclides using criteria that differ principally from those used previously in selecting among nontoxic antioxidants, immunomodulators, and adaptogens; (2) study systematically the synergism of low doses of harmful agents and review the hygienic standardization system with due regard for the risk from their combinations; (3) consider comprehensively, on the basis of the experimental and clinical experience, the problem of "hot" particles and remote consequences of their influence on the respiratory and digestive systems; (4) study independently the problem of chronic stress as a combination of radiation effects and psycho-emotional consequences of the accident and living in the exposed areas; (5) consider it inadmissible to include in the B category the population of the districts influenced by the accident and to use the concept: "35 rads during the lifetime" in standardizing the radiation load; (6) organize a comprehensive analysis of the Chernobyl accident consequences for public health within the contaminated areas as well as for animals and plants using a single approved methodology and programme, the principle of "other equal conditions" being provided.

  14. An Interlaboratory Comparison of Dosimetry for a Multi-institutional Radiobiological

    PubMed Central

    Seed, TM; Xiao, S; Manley, N; Nikolich-Zugich, J; Pugh, J; van den Brink, M; Hirabayashi, Y; Yasutomo, K; Iwama, A; Koyasu, S; Shterev, I; Sempowski, G; Macchiarini, F; Nakachi, K; Kunugi, KC; Hammer, CG; DeWerd, LA

    2016-01-01

    Purpose An interlaboratory comparison of radiation dosimetry was conducted to determine the accuracy of doses being used experimentally for animal exposures within a large multi-institutional research project. The background and approach to this effort are described and discussed in terms of basic findings, problems and solutions. Methods Dosimetry tests were carried out utilizing optically stimulated luminescence (OSL) dosimeters embedded midline into mouse carcasses and thermal luminescence dosimeters (TLD) embedded midline into acrylic phantoms. Results The effort demonstrated that the majority (4/7) of the laboratories was able to deliver sufficiently accurate exposures having maximum dosing errors of ≤ 5%. Comparable rates of ‘dosimetric compliance’ were noted between OSL- and TLD-based tests. Data analysis showed a highly linear relationship between ‘measured’ and ‘target’ doses, with errors falling largely between 0–20%. Outliers were most notable for OSL-based tests, while multiple tests by ‘non-compliant’ laboratories using orthovoltage x-rays contributed heavily to the wide variation in dosing errors. Conclusions For the dosimetrically non-compliant laboratories, the relatively high rates of dosing errors were problematic, potentially compromising the quality of ongoing radiobiological research. This dosimetry effort proved to be instructive in establishing rigorous reviews of basic dosimetry protocols ensuring that dosing errors were minimized. PMID:26857121

  15. Gamma knife radiosurgery in movement disorders: Indications and limitations.

    PubMed

    Higuchi, Yoshinori; Matsuda, Shinji; Serizawa, Toru

    2017-01-01

    Functional radiosurgery has advanced steadily during the past half century since the development of the gamma knife technique for treating intractable cancer pain. Applications of radiosurgery for intracranial diseases have increased with a focus on understanding radiobiology. Currently, the use of gamma knife radiosurgery to ablate deep brain structures is not widespread because visualization of the functional targets remains difficult despite the increased availability of advanced neuroimaging technology. Moreover, most existing reports have a small sample size or are retrospective. However, increased experience with intraoperative neurophysiological evaluations in radiofrequency thalamotomy and deep brain stimulation supports anatomical and neurophysiological approaches to the ventralis intermedius nucleus. Two recent prospective studies have promoted the clinical application of functional radiosurgery for movement disorders. For example, unilateral gamma knife thalamotomy is a potential alternative to radiofrequency thalamotomy and deep brain stimulation techniques for intractable tremor patients with contraindications for surgery. Despite the promising efficacy of gamma knife thalamotomy, however, these studies did not include sufficient follow-up to confirm long-term effects. Herein, we review the radiobiology literature, various techniques, and the treatment efficacy of gamma knife radiosurgery for patients with movement disorders. Future research should focus on randomized controlled studies and long-term effects. © 2016 International Parkinson and Movement Disorder Society. © 2016 International Parkinson and Movement Disorder Society.

  16. Computational modeling of radiobiological effects in bone metastases for different radionuclides.

    PubMed

    Liberal, Francisco D C Guerra; Tavares, Adriana Alexandre S; Tavares, João Manuel R S

    2017-06-01

    Computational simulation is a simple and practical way to study and to compare a variety of radioisotopes for different medical applications, including the palliative treatment of bone metastases. This study aimed to evaluate and compare cellular effects modelled for different radioisotopes currently in use or under research for treatment of bone metastases using computational methods. Computational models were used to estimate the radiation-induced cellular effects (Virtual Cell Radiobiology algorithm) post-irradiation with selected particles emitted by Strontium-89 ( 89 Sr), Samarium-153 ( 153 Sm), Lutetium-177 ( 177 Lu), and Radium-223 ( 223 Ra). Cellular kinetics post-irradiation using 89 Sr β - particles, 153 Sm β -  particles, 177 Lu β -  particles and 223 Ra α particles showed that the cell response was dose- and radionuclide-dependent. 177 Lu beta minus particles and, in particular, 223 Ra alpha particles, yielded the lowest survival fraction of all investigated particles. 223 Ra alpha particles induced the highest cell death of all investigated particles on metastatic prostate cells in comparison to irradiation with β -  radionuclides, two of the most frequently used radionuclides in the palliative treatment of bone metastases in clinical routine practice. Moreover, the data obtained suggest that the used computational methods might provide some perception about cellular effects following irradiation with different radionuclides.

  17. On the impact of improved dosimetric accuracy on head and neck high dose rate brachytherapy.

    PubMed

    Peppa, Vasiliki; Pappas, Eleftherios; Major, Tibor; Takácsi-Nagy, Zoltán; Pantelis, Evaggelos; Papagiannis, Panagiotis

    2016-07-01

    To study the effect of finite patient dimensions and tissue heterogeneities in head and neck high dose rate brachytherapy. The current practice of TG-43 dosimetry was compared to patient specific dosimetry obtained using Monte Carlo simulation for a sample of 22 patient plans. The dose distributions were compared in terms of percentage dose differences as well as differences in dose volume histogram and radiobiological indices for the target and organs at risk (mandible, parotids, skin, and spinal cord). Noticeable percentage differences exist between TG-43 and patient specific dosimetry, mainly at low dose points. Expressed as fractions of the planning aim dose, percentage differences are within 2% with a general TG-43 overestimation except for the spine. These differences are consistent resulting in statistically significant differences of dose volume histogram and radiobiology indices. Absolute differences of these indices are however small to warrant clinical importance in terms of tumor control or complication probabilities. The introduction of dosimetry methods characterized by improved accuracy is a valuable advancement. It does not appear however to influence dose prescription or call for amendment of clinical recommendations for the mobile tongue, base of tongue, and floor of mouth patient cohort of this study. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. Feasibility study for a biomedical experimental facility based on LEIR at CERN.

    PubMed

    Abler, Daniel; Garonna, Adriano; Carli, Christian; Dosanjh, Manjit; Peach, Ken

    2013-07-01

    In light of the recent European developments in ion beam therapy, there is a strong interest from the biomedical research community to have more access to clinically relevant beams. Beamtime for pre-clinical studies is currently very limited and a new dedicated facility would allow extensive research into the radiobiological mechanisms of ion beam radiation and the development of more refined techniques of dosimetry and imaging. This basic research would support the current clinical efforts of the new treatment centres in Europe (for example HIT, CNAO and MedAustron). This paper presents first investigations on the feasibility of an experimental biomedical facility based on the CERN Low Energy Ion Ring LEIR accelerator. Such a new facility could provide beams of light ions (from protons to neon ions) in a collaborative and cost-effective way, since it would rely partly on CERN's competences and infrastructure. The main technical challenges linked to the implementation of a slow extraction scheme for LEIR and to the design of the experimental beamlines are described and first solutions presented. These include introducing new extraction septa into one of the straight sections of the synchrotron, changing the power supply configuration of the magnets, and designing a new horizontal beamline suitable for clinical beam energies, and a low-energy vertical beamline for particular radiobiological experiments.

  19. Feasibility study for a biomedical experimental facility based on LEIR at CERN

    PubMed Central

    Abler, Daniel; Garonna, Adriano; Carli, Christian; Dosanjh, Manjit; Peach, Ken

    2013-01-01

    In light of the recent European developments in ion beam therapy, there is a strong interest from the biomedical research community to have more access to clinically relevant beams. Beamtime for pre-clinical studies is currently very limited and a new dedicated facility would allow extensive research into the radiobiological mechanisms of ion beam radiation and the development of more refined techniques of dosimetry and imaging. This basic research would support the current clinical efforts of the new treatment centres in Europe (for example HIT, CNAO and MedAustron). This paper presents first investigations on the feasibility of an experimental biomedical facility based on the CERN Low Energy Ion Ring LEIR accelerator. Such a new facility could provide beams of light ions (from protons to neon ions) in a collaborative and cost-effective way, since it would rely partly on CERN's competences and infrastructure. The main technical challenges linked to the implementation of a slow extraction scheme for LEIR and to the design of the experimental beamlines are described and first solutions presented. These include introducing new extraction septa into one of the straight sections of the synchrotron, changing the power supply configuration of the magnets, and designing a new horizontal beamline suitable for clinical beam energies, and a low-energy vertical beamline for particular radiobiological experiments. PMID:23824122

  20. An Empirical Analysis of an Alternative Configuration of the Academic Motivation Scale

    ERIC Educational Resources Information Center

    Smith, Kenneth J.; Davy, Jeanette A.; Rosenberg, Donald L.

    2012-01-01

    The purpose of this study was to examine an alternative configuration of the Academic Motivation Scale (AMS), a psychometric instrument used as a measure of academic motivation in various academic environments. The analyses utilised data from a convenience sample of 2354 business students, broken into two random subsamples of 1177 cases.…

  1. Using the University Student Depression Inventory to Investigate the Effect of Demographic Variables on Students' Depression

    ERIC Educational Resources Information Center

    Khawaja, Nigar G.; Duncanson, Krystle

    2008-01-01

    Depression is a problem in the student population and may impact students of any age, gender and ethnicity. Previous studies have indicated student demographic characteristics are associated with depression; however, these studies have not utilised scales specifically designed to measure depression in the student population. The aim of the present…

  2. An Epistemological Analysis of the Application of an Online Inquiry-Based Program in Tourism Education

    ERIC Educational Resources Information Center

    Hsu, Liwei

    2014-01-01

    This paper was designed to investigate the application of an online inquiry-based program to European tourism from an epistemological perspective. Fifty tourism students (n = 50) participated in this study and their epistemological beliefs were measured with the Epistemological Belief Scale. A set of pre-, post-, and delayed tests were utilised to…

  3. Social Networking and the Social and Emotional Wellbeing of Adolescents in Australia

    ERIC Educational Resources Information Center

    Bourgeois, Amanda; Bower, Julie; Carroll, Annemaree

    2014-01-01

    Technology and social networking tools and sites are changing the way young people build and maintain their social connections with others (Boyd & Ellison, 2008). This study utilised a new measure, The Self in a Social Context, Virtual Connectedness subscale (SSC-VC subscale), to examine the effects of social networking tools and sites on…

  4. Becoming an Interdisciplinary Scientist: An Analysis of Students' Experiences in Three Computer Science Doctoral Programmes

    ERIC Educational Resources Information Center

    Calatrava Moreno, María del Carmen; Danowitz, Mary Ann

    2016-01-01

    The aim of this study was to identify how and why doctoral students do interdisciplinary research. A mixed-methods approach utilising bibliometric analysis of the publications of 195 students identified those who had published interdisciplinary research. This objective measurement of the interdisciplinarity, applying the Rao-Stirling index to Web…

  5. Novel utilisation of a circular multi-reflection cell applied to materials ageing experiments

    NASA Astrophysics Data System (ADS)

    Knox, D. A.; King, A. K.; McNaghten, E. D.; Brooks, S. J.; Martin, P. A.; Pimblott, S. M.

    2015-04-01

    We report on the novel utilisation of a circular multi-reflection (CMR) cell applied to materials ageing experiments. This enabled trace gas detection within a narrow interfacial region located between two sample materials and remotely interrogated with near-infrared sources combined with fibre-optic coupling. Tunable diode laser absorption spectroscopy was used to detect water vapour and carbon dioxide at wavelengths near 1,358 and 2,004 nm, respectively, with corresponding detection limits of 7 and 1,139 ppm m Hz-0.5. The minimum detectable absorption was estimated to be 2.82 × 10-3 over a 1-s average. In addition, broadband absorption spectroscopy was carried out for the detection of acetic acid, using a super-luminescent light emitting diode centred around 1,430 nm. The 69 cm measurement pathlength was limited by poor manufacturing tolerances of the spherical CMR mirrors and the consequent difficulty of collecting all the cell output light.

  6. Solar flare induced cosmic noise absorption

    NASA Astrophysics Data System (ADS)

    Ogunmodimu, Olugbenga; Honary, Farideh; Rogers, Neil; Falayi, E. O.; Bolaji, O. S.

    2018-06-01

    Solar flare events are a major observing emphasis for space weather because they affect the ionosphere and can eject high-energy particles that can adversely affect Earth's technologies. In this study we model 38.2 MHz cosmic noise absorption (CNA) by utilising measurements from the Imaging Riometer for Ionospheric Studies (IRIS) at Kilpisjärvi, Finland obtained during solar cycle 23 (1996-2009). We utilised X-ray archive for the same period from the Geostationary Operational Environmental Satellite (GOES) to study solar flare induced cosmic noise absorption. We identified the threshold of flare (M4 class) that could bear significant influence on CNA. Through epoch analysis, we show the magnitude of absorption that each class of flare could produce. Using the parameters of flare and absorption we present a model that could provide the basis for nowcast of CNA induced by M and X-class solar flares.

  7. Odour and ammonia emissions from intensive poultry units in Ireland.

    PubMed

    Hayes, E T; Curran, T P; Dodd, V A

    2006-05-01

    Odour and ammonia emissions were measured from three broiler, two layer and two turkey houses in Ireland. The broiler units gave a large range of odour and ammonia emission rates depending on the age of the birds and the season. A considerable variation between the odour and ammonia emission rates was evident for the two layer units which may have been due to the different manure handling systems utilised in the houses. There was relatively little difference in the odour and ammonia emissions from the two turkey houses. As a precautionary principle, odour emission rates utilised in atmospheric dispersion models should use the maximum values for broilers and turkeys (1.22 and 10.5 ou(E) s(-1) bird(-1) respectively) and the mean value for the layers depending on the manure handling system used (0.47 or 1.35 ou(E) s(-1) bird(-1)).

  8. Complexation induced fluorescence and acid-base properties of dapoxyl dye with γ-cyclodextrin: a drug-binding application using displacement assays.

    PubMed

    Pal, Kaushik; Mallick, Suman; Koner, Apurba L

    2015-06-28

    Host-guest complexation of dapoxyl sodium sulphonate (DSS), an intramolecular charge transfer dye with water-soluble and non-toxic macrocycle γ-cyclodextrin (γ-CD), has been investigated in a wide pH range. Steady-state absorption, fluorescence and time-resolved fluorescence measurements confirm the positioning of DSS into the hydrophobic cavity of γ-CD. A large fluorescence enhancement ca. 30 times, due to 1 : 2 complex formation and host-assisted guest-protonation have been utilised for developing a method for the utilisation of CD based drug-delivery applications. A simple fluorescence-displacement based approach is implemented at physiological pH for the assessment of binding strength of pharmaceutically useful small drug molecules (ibuprofen, paracetamol, methyl salicylate, salicylic acid, aspirin, and piroxicam) and six important antibiotic drugs (resazurin, thiamphenicol, chloramphenicol, ampicillin, kanamycin, and sorbic acid) with γ-CD.

  9. The smartphone in the memory clinic: A study of patient and care partner's utilisation habits.

    PubMed

    Benge, Jared F; Dinh, Kara L; Logue, Erin; Phenis, Richard; Dasse, Michelle N; Scullin, Michael K

    2018-04-16

    Smartphones have potential as cognitive aids for adults with cognitive impairments. However, little is known about how patients and their care partners utilise smartphones in their day-to-day lives. We collected self-reported smartphone utilisation data from patients referred for neuropsychological evaluations (N = 53), their care partners (N = 44), and an Amazon Mechanical Turk control sample (N = 204). Patient participants were less likely to own a smartphone than controls, with increasing age associated with less utilisation of smartphone features in all groups. Of the patients who owned smartphones, spontaneous use of cognitive aid features (e.g., reminders and calendars) occurred on only a monthly-to-weekly basis; by comparison, patients reported utilising social/general features (e.g., email and internet) on a weekly-to-daily basis. Individuals referred for geriatric cognitive disorder evaluations were less likely to own and use smartphones than individuals referred for other reasons. Care partners reported using their smartphones more frequently than control group adults, with 55% of care partners endorsing utilising their device in caring for the patient. Building upon existing smartphone use habits to increase the use of cognitive aid features may be a feasible intervention for some patients, and including care partners in such interventions is encouraged.

  10. Socioeconomic inequalities in health care utilisation in Norway: the population-based HUNT3 survey.

    PubMed

    Vikum, Eirik; Krokstad, Steinar; Westin, Steinar

    2012-08-22

    In this study we investigated the distribution of self-reported health care utilisation by education and household income in a county population in Norway, in a universal public health care system based on ideals of equal access for all according to need, and not according to wealth. The study included 24,147 women and 20,608 men aged 20 years and above in the third Nord-Trøndelag Health Survey (HUNT 3) of 2006-2008. Income-related horizontal inequity was estimated through concentration indexes, and inequity by both education and income was estimated as risk ratios through conventional regression. We found no overall pro-rich or pro-educated socioeconomic gradient in needs-adjusted utilisation of general practitioner or inpatient care. However, we found overall pro-rich and pro-educated inequity in utilisation of both private medical specialists and hospital outpatient care. For these services there were large differences in levels of inequity between younger and older men and women. In contrast with recent studies from Norway, we found pro-rich and pro-educated social inequalities in utilisation of hospital outpatient services and not only private medical specialists. Utilisation of general practitioner and inpatient services, which have low access threshold or are free of charge, we found to be equitable.

  11. Impact of Nutritional Status and Sleep Quality on Hospital Utilisation in the Oldest Old with Heart Failure.

    PubMed

    Selan, S; Hellström, A; Fagerström, C

    2016-02-01

    To describe three-year trends in nutritional status and sleep quality and their impact on hospital utilisation in the oldest old (80 +) with heart failure (HF). Single-centred longitudinal observational study. South-eastern Sweden. 90 elderly (80+) with objectively verified HF. Baseline data from the Mini Nutritional Assessment (MNA) and on sleep quality were collected through structured interviews following the HF diagnosis (n=90) and at a three-year follow-up (n=41). Data on hospital utilisation during the three years following the HF diagnosis were also collected. Nineteen percent of the participants were found to have impaired nutritional status, a condition that increased hospital utilisation by four bed days per year. A majority (85%) had impaired sleep quality, but no impact on hospital utilisation was found. Nutritional status and sleep quality were stable over the three-year period. In the oldest old with HF, impaired nutritional status and impaired sleep quality are already common at HF diagnosis. Impaired nutritional status increases hospital utilisation significantly. Therefore, it is of supreme importance to systematically evaluate nutritional status and sleep quality in the oldest old when they are diagnosed with HF, as well as to take action if impairments are present.

  12. COPD: Health Care Utilisation Patterns with Different Disease Management Interventions.

    PubMed

    Luk, Edwin K; Hutchinson, Anastasia F; Tacey, Mark; Irving, Louis; Khan, Fary

    2017-08-01

    The management of COPD is a significant and costly issue worldwide, with acute healthcare utilisation consisting of admissions and outpatient attendances being a major contributor to the cost. Pulmonary rehabilitation (PR) and integrated disease management (IDM) are often offered. Whilst there is strong evidence of physical and quality of life outcomes following IDM and PR, few studies have looked into healthcare utilisation. The aims of this study were to confirm whether IDM and PR reduce acute healthcare utilisation and to identify factors which contribute to acute health care utilisation or increased mortality. This was a retrospective cohort study of patients with COPD who were referred to IDM over a 10-year period. Patients were also offered an 8-week PR program. Data collected were matched with the hospital dataset to obtain information on inpatient, ED and outpatient attendances. 517 patients were enrolled to IDM. 315 (61%) also commenced PR and 220 (43%) completed PR. Patients who were referred to PR were younger and had less comorbidities (p < 0.001). Both groups (IDM only and IDM + PR referred) had reductions in healthcare utilisation but the IDM-only group had greater reductions. A survival benefit (HR 0.68, 95% CI 0.50-0.92) was seen in those who were PR completers compared to patients who received IDM only. Patients with COPD who successfully complete PR in addition to participating in IDM have improved survival. IDM alone was effective in the reduction of healthcare utilisation; however, the addition of PR did not reduce healthcare usage further.

  13. Evaluation de l'intergiciel de communication DDS pour son utilisation dans le domaine avionique

    NASA Astrophysics Data System (ADS)

    Levesque-Landry, Kevin

    Les aeronefs modernes doivent combler de plus en plus de fonctionnalites afin de satisfaire les besoins de la clientele. De ce fait, les besoins en communications des systemes avioniques sont grandissants. De plus, la portabilite et la reutilisabilite des applications sont des defis d'actualite dans le domaine avionique. De ce fait, ce projet de recherche vise a faire une evaluation de la technologie d'intergiciel de service de distribution de donnees (DDS) pour son utilisation dans le domaine avionique. Cette technologie permettrait de reduire la complexite des communications et faciliter la portabilite et reutilisabilite des applications grâce a son interface standardisee. Dans ce projet de recherche, la norme DDS est tout d'abord etudiee pour cibler les fonctionnalites qui sont utiles au domaine avionique. Les differentes polices de qualite de services sont ainsi etudiees et denotent la flexibilite de la technologie DDS. Un intergiciel DDS est egalement evalue dans un environnement de laboratoire afin de mesurer l'impact de l'utilisation de cette technologie sur les performances de latence ainsi que sur l'utilisation de la bande passante. Les resultats montrent une faible augmentation de la latence moyenne lorsque l'intergiciel DDS est utilise. L'intergiciel DDS est egalement utilise dans une etude de cas avec un AFCS (automatic flight control system) afin de quantifier les effets de son utilisation sur une application avionique. Les resultats montrent que l'utilisation de l'intergiciel DDS n'empeche pas l'AFCS d'atteindre la stabilite, mais qu'elle ralentit l'atteinte de cette derniere. Finalement, une etude de cas est effectuee afin de valider que la technologie DDS peut etre utilisee pour construire des systemes redondants. Les resultats montrent que l'intergiciel DDS permet de faire de la redondance de reserve sans avoir un impact visible sur les performances du systeme redondant.

  14. Professor Hassan K. Awwad; The Father of Radiation Oncology and Radiobiology in Egypt and the Arab World, His Good Deeds Last Forever and Inspire us for the Future.

    PubMed

    Zaghloul, Mohamed S; El-Badawi, Samy A; Abd Elbaky, Hoda

    2007-03-01

    Our most respected professor Hassan K. Awwad passed away on January 5th, 2007, at the age of 81. He was considered as the father of radiotherapy in Egypt. He was always named "The Professor", as he was the founder of the radiotherapy departments at the National Cancer Institute, Cairo University&Faculty of Medicine, Alexandria University. He also shared in developing NEMROCK (Kasr El Aini Center of Radiation Oncology and Nuclear Medicine), the place where he graduated and worked during his early years of experience. He, together with professor Reda Hamza, dean of NCI, Cairo at that time, had initiated 7 oncology centers all over Egypt, from Aswan in the South to Dammietta and Damanhour in the North. These 7 centers were developed by the Ministry of Health. Prof. Awwad and Prof. Hamza were responsible for facility providing and plans. They chose all the necessary equipment, tools and personnel. These centers were in action since 1988 and are currently taking care of the oncology patients in a wide area of the country. Prof. Awwad graduated from the Faculty of medicine, Cairo University, in 1949. He had his Medical Doctorate (MD) in Radiotherapy from Alexandria University in 1956. The International Atomic Energy Agency (IAEA) awarded him fellowships in France (Institute Gustave Rossy) to gain experience in brachytherapy in 1956 and 1971, England 1956, 1959. Another fellowship was awarded to Prof Awwad in Harvard University (Peter Bent Brigham Hospital) in radiobiology and radiotherapy during the years 1964-1965. He personally and with other members of the National Cancer Institute gave much of their efforts and time to teach, train and guide young radiotherapists, biologists, physicists and radiation therapists through direct on-hand teaching and training as well as holding training courses for radiation oncologists, physicists and technologists. He insisted to ensure its regularity 4 times yearly. These courses trained a lot of personnel from all over Egypt, Sudan, Libya, Palastine, Iraq, Uganda, Nigeria and other countries. He himself had many teaching missions in different Arab countries (Saudi Arabia, Kuwait and others) for the sake of groups of his students that could not come to Egypt. He served as the head of the Department of Radiation Oncology for more than 15 years (1970-1985), full time Professor in Radiation Oncology and Radiobiology (1985-2007), Professor of Radiotherapy, Alexandria University (1954-1970), Chief of the Department of Nuclear Medicine, Medical Research Institute, University of Alexandria (1963-1964), Chief of the Radiotherapy Unit in the Heliopolis Hospital, Ministry of Public Health, 1985-2007. He was co-founder of the Egyptian Society of Cancer and acted as vice present and head of the scientific committee of the society. He shared the activities of many Egyptian, Arab and international scientific societies. His activities in these societies were great. Prof. Awwad had direct contact with his students that never ended, even after some of them left to work in other places in USA, Canada, Europe or Arab Countries. His students' specialty varied between radiobiology, pharmacology, biochemistry, tumor biology, radiation oncology, medical oncology and surgical oncology. Prof. Awwad had more than 100 published articles on hypoxia and hypoxic cell radiosensitizers, biology of growth of human tumors, biology and clinical models of the time factor in external beam radiotherapy, biology and mathematical models of time factor in brachytherapy, radioactive dynamic cancer studies of plasma protein metabolism, radioactive dynamic factor studies of blood disorders and lymphoma, radiation damage of DNA and normal tissues,head and neck cancer, bladder cancer, breast cancer, cervical cancer and development and optimization of clinical radiotherapy. He had continuous cooperation and collaboration with many of the great scientists and clinicians in Holland, France, United Kingdom, USA and Japan. He continued to exchange ideas with these great people all through his life and till the last moments of his extended fruitful life. Prof. Awwad wrote many books for a wide diversity of readers, for the lay people in Arabic, for radiographers, young oncologist, and the highly experienced radiation oncologists and radiobiologists. His book "Radiation Oncology: Radiobiological and Physiobiological Perspectives" was a real translation of radiobiology language to the oncologist and at the same time translation of the oncologist language to the biologist. This book ended with establishing a common language for both teams. In addition, it led other books in these specialties to communicate with the same language. The good news is that Prof. Awwad had completed the second edition of this book just before passing away. This second edition is really a totally new book coping with the advancement of knowledge reached till the end of 2006. We are sure that this book with all other good deeds performed by Prof. Awwad, will keep his memory in Egypt as well as elsewhere in the whole world.

  15. Measuring and decomposing socioeconomic inequality in healthcare delivery: A microsimulation approach with application to the Palestinian conflict-affected fragile setting.

    PubMed

    Abu-Zaineh, Mohammad; Mataria, Awad; Moatti, Jean-Paul; Ventelou, Bruno

    2011-01-01

    Socioeconomic-related inequalities in healthcare delivery have been extensively studied in developed countries, using standard linear models of decomposition. This paper seeks to assess equity in healthcare delivery in the particular context of the occupied Palestinian territory: the West Bank and the Gaza Strip, using a new method of decomposition based on microsimulations. Besides avoiding the 'unavoidable price' of linearity restriction that is imposed by the standard methods of decomposition, the microsimulation-based decomposition enables to circumvent the potentially contentious role of heterogeneity in behaviours and to better disentangle the various sources driving inequality in healthcare utilisation. Results suggest that the worse-off do have a disproportinately greater need for all levels of care. However with the exception of primary-level, utilisation of all levels of care appears to be significantly higher for the better-off. The microsimulation method has made it possible to identify the contributions of factors driving such pro-rich patterns. While much of the inequality in utilisation appears to be caused by the prevailing socioeconomic inequalities, detailed analysis attributes a non-trivial part (circa 30% of inequalities) to heterogeneity in healthcare-seeking behaviours across socioeconomic groups of the population. Several policy recommendations for improving equity in healthcare delivery in the occupied Palestinian territory are proposed. Copyright © 2010 Elsevier Ltd. All rights reserved.

  16. Acceptance and utilisation of the Incident Command System in first response and allied disciplines: an Ohio study.

    PubMed

    Decker, Russell J

    2011-10-01

    In response to the terrorist attacks of September 11th, 2001, an effort was made to establish a common and uniform command structure for use by the nation's first responder organisations, as well as those disciplines generally expected to assist first responders during a major incident or disaster. The result was the issuance of the National Incident Management System1 or NIMS by the US Department of Homeland Security in 2004. Included in the NIMS document was an embracing of the Incident Command System or ICS, long utilised in the fire service for the effective management of emergency response. The NIMS doctrine also identified certain allied disciplines that needed to adopt this new system for responding to major events. Some of these disciplines included specialised first response units, such as, bomb squads and hazardous materials teams. Other partner disciplines not usually associated with emergency response to include public health and public works were also included. This study will attempt to look at a single component of NIMS, specifically the Incident Command System, and measure its acceptance and utilisation by first responder organisations and selected allied disciplines in the state of Ohio. This is particularly important at this time since the US government is being forced to reduce budgets significantly and determine which laudable policies and programmes will be cut.

  17. Nutritional values and bioactive components of under-utilised vegetables consumed by indigenous people in Malaysia.

    PubMed

    Abdul Wahab, Norsuhaila; Ahdan, Rohaina; Ahmad Aufa, Zabidah; Kong, Kin Weng; Johar, Mohd Hafizan; Shariff Mohd, Zalilah; Ismail, Amin

    2015-10-01

    Diverse plants species in the forest remain under-utilised and they are mainly consumed only by local people. However, increasing issues in food security prompted the present study, which explores the nutritional and antioxidant aspects of Malaysian under-utilised vegetables. The studied vegetables were Paku Nyai (Stenochlaena palustris), Cemperai (Champereia manillana), Maman Pasir (Cleome viscose), Dudung (Erechtites valerianifolia) and Semambuk (Ardisia pendula). Overall, these vegetables exhibited a low proximal content but they were high in vitamin C [7.07-1263 mg kg(-1) edible fresh sample (EFS)] and β-carotene content (18.4-43.9 mg kg(-1) kg(-1) EFS). Cemperai had the highest calcium content (565 mg kg(-1) EFS), whereas Semambuk had the highest total phenolic content [28.21 g gallic acid equivalents kg(-1) edible dried sample (EDS)] and antioxidant activity (86.1%) measured using β-carotene bleaching assay. Maman Pasir contained the highest total flavonoid content (39.99 g CE kg(-1) EDS) and 1,1-diphenyl-2-picryl hydrazyl radical scavenging activity (82.2%). The extracts of these vegetables had significantly prevented the oxidation of haemoglobin and low-density lipoprotein, which yielded a reduced production of malondialdehyde. Semambuk and Maman Pasir are potent to be used as new food and functional food sources as they are rich in nutrients and antioxidants. © 2014 Society of Chemical Industry.

  18. Contraceptive Utilisation Among Mothers of Reproductive Age in Ajman, United Arab Emirates.

    PubMed

    Kanwal, Naila; Muttappallymyalil, Jayakumary; Al-Sharbatti, Shatha; Ismail, Iman

    2017-02-01

    This study aimed to determine contraceptive utilisation among mothers aged 18-49 years old in Ajman, United Arab Emirates (UAE). This cross-sectional study was carried out from May to November 2013. A total of 400 participants were recruited from two primary healthcare centres and one private hospital in Ajman. An interviewer-administered validated questionnaire was used for data collection. The frequency of previous and current contraceptive use was 68.0% and 61.8%, respectively. Expatriates more frequently used contraceptives in comparison to Emiratis (77.3% versus 54.3%, respectively). Contraceptive use increased significantly with age (75.5% among >35-year-olds versus 57.3% among ≤25-year-olds; P <0.050) and education level (83.3% among postgraduates versus 60.0% among those with primary education; P <0.050). In addition, contraceptive use was significantly higher among those living in a nuclear family system ( P <0.050). A univariate analysis indicated significant associations between contraceptive use and age, nationality, education level, type of family system, employment sector, parity, knowledge of birth control measures and source of birth control information ( P <0.050 each). However, no significant associations were found via multivariate analysis. Healthcare practitioners can play a pivotal role in providing contraceptive advice which could lead to an improvement in contraceptive utilisation. Efforts are recommended to raise awareness regarding newer forms of contraceptives among mothers of reproductive age in the UAE.

  19. AFRRI (Armed Forces Radiobiology Research Institute) Annual Research Report 1 October 1982-30 September 1983.

    DTIC Science & Technology

    1983-09-30

    glucan on granulopoiesis and macrophage genesis in mice. Cancer Research 37: 1739-1742, 1979. 2. Patchen, M. L., and Lotzova, 1. Modulation of m urine... beta - endorphin are elevated following exposure to acute stress. Therefore, the present study sought to determine if behavioml cross-tolerance could...Effects on hepatic enzymes, delayed type hypersensitivity, and postirradiation survival of mice. In: Modulation and Mediation of Cancer by Vitamins

  20. AFRRI (Armed Forces Radiobiology Research Institute) Reports, October, November, December 1986

    DTIC Science & Technology

    1986-12-01

    Acta Chemica Scandinavica, 20, 494-504. RUPPRECHT, A., 1970a, A wet spinning apparatus and auxiliary equipment suitable for preparing samples of...Acta Chemica Scandinavica, B33, 779-780. SEVILLA, M. D., FAILOR, R., CLARK, C, HOLROYD, R. A., and PETTEI, M., 1976, Electron transfer in dinucleoside...spinning. Acta Chemica Scandinavica, 20, 494-504. RUPPRECHT, A., 1970a, A wet spinning apparatus and auxiliary equipment suitable for preparing samples

  1. Changes in whole-body metabolic parameters associated with radiation

    NASA Astrophysics Data System (ADS)

    Ahlers, I.

    1994-10-01

    Continuous irradiation of experimental animals is an appropriate model for the research in space radiobiology. The onset and recovery of radiation injury can be estimated on the basis of the concentration/content of glycogen in liver, the phospholipid content in thymus and other radiosensitive organs and the triacylglycerol concentration in bone marrow. Further, the picture of the metabolism in irradiated organism may be completed by the analysis of serum glucocorticoid and thyroid hormone levels.

  2. The TRIGA Reactor Facility at the Armed Forces Radiobiology Research Institute: A Simplified Technical Description.

    DTIC Science & Technology

    1986-05-01

    COUNT Technical FROM_ TO May 1986 20 16. SUPPLEMENTARY NOTATION 17. COSATI CODES 18. SUBJECT TERMS iConitinue on reverse if neceasary and identify by...Reactor, Modes of Operation, The AFRRI Reactor, Exposure Facilities, and Cerenkov Radiation. I- 20 DISTRISUTIONIAVAILABILITY OF ABSTRACT 21. ABSTRACT...6 Exposure Facilities 12 Cerenkov Radiation 17 Acoessiofl For NTIS GRA&I DT.C TABUnamnnounced [] UusnriOfltond -. By IZ Distribution/ Availability

  3. Bikini scientific resurvey. Volume II. Report of the technical director. Technical report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1947-12-01

    Contents: Island and Reef Geology; Submarine Geology; Drilling Operations; Radiobiology Studies; Reef and Lagoon Fishes; Pelagic Fishes; Taxonomy and Teratology of Fishes; Invertebrate Embryology; Vertebrate Embryology; Reef and Lagoon Algae; Chemical Effects of Organisms Upon Sea Water; The Insect Population; Marine Invertebrates; Land Animals; Plankton Studies; Counter-Room Activities; Radiochemical Analyses; Soils Chemistry; Low-Level Radiation Studies; Army Engineering Studies; Aerological Data; Bacteriological Investigations; Radiological Safety; Radiological Health; Technical Director's Summary.

  4. AFRRI (Armed Forces Radiobiology Research Institute) Reports, January-March 1985

    DTIC Science & Technology

    1985-01-01

    monkey and human gastric functions Address osl i ,194 Arorlett: July~ (1, 1118. (6). .). and thle drug dosage was close to that ustid inAi~oattno...ionization chambers this requires the use of the two- * dosimeter method. One of the chambers is constructed of A-150 tissue- equivalent (TE) plastic, and...out excessively high flow rates. A photon energy-compensated Geiger- * Muller (GM) dosimeter is often used as the second dosimeter . However

  5. Where Radiobiology Began in Russia: A Physician’s Perspective

    DTIC Science & Technology

    2010-09-01

    radiation incidents at the MPA and conduct studies of long-term health effects of radiation exposure on that population and also the general public along...White Archipelago”) (Gubarev, 2004): “Visiting a number of production facilities that worked with plutonium and polonium - 210 , I was struck by the...were established for major food products. These standards, of course, were higher than the Union-wide public health standards. They did not begin

  6. Jordanian TEFL Graduate Students' Use of Critical Thinking Skills (as Measured by the Cornell Critical Thinking Test, Level Z)

    ERIC Educational Resources Information Center

    Bataineh, Ruba Fahmi; Zghoul, Lamma Hmoud

    2006-01-01

    This study investigates the critical thinking skills of 50 students currently enrolled in the Master's TEFL Programme at Yarmouk University, Jordan. The Cornell Critical Thinking Test, Level Z is utilised to test the students' use, or lack thereof, of the critical thinking skills of deduction, semantics, credibility, induction, definition and…

  7. A Relationship between Early Language Skills and Adult Autistic-Like Traits: Evidence from a Longitudinal Population-Based Study

    ERIC Educational Resources Information Center

    Armstrong, Rebecca; Whitehouse, Andrew J. O.; Scott, James G.; Copland, David A.; McMahon, Katie L.; Fleming, Sophie; Arnott, Wendy

    2017-01-01

    The current study examined the relationship between early language ability and autistic-like traits in adulthood, utilising data from 644 participants from a longitudinal study of the general population. Language performance at 2 years was measured with the Language Development Survey (LDS), and at 20 years the participants completed the…

  8. A scoping review of traditional food security in Alaska.

    PubMed

    Walch, Amanda; Bersamin, Andrea; Loring, Philip; Johnson, Rhonda; Tholl, Melissa

    2018-12-01

    Food insecurity is a public health concern. Food security includes the pillars of food access, availability and utilisation. For some indigenous peoples, this may also include traditional foods. To conduct a scoping review on traditional foods and food security in Alaska. Google Scholar and the High North Research Documents were used to search for relevant primary research using the following terms: "traditional foods", "food security", "access", "availability", "utilisation", "Alaska", "Alaska Native" and "indigenous". Twenty four articles from Google Scholar and four articles from the High North Research Documents were selected. The articles revealed three types of research approaches, those that quantified traditional food intake (n=18), those that quantified food security (n=2), and qualitative articles that addressed at least one pillar of food security (n=8). Limited primary research is available on food security in Alaskan. Few studies directly measure food security while most provide a review of food security factors. Research investigating dietary intake of traditional foods is more prevalent, though many differences exist among participant age groups and geographical areas. Future research should include direct measurements of traditional food intake and food security to provide a more complete picture of traditional food security in Alaska.

  9. Improved sugar co-utilisation by encapsulation of a recombinant Saccharomyces cerevisiae strain in alginate-chitosan capsules

    PubMed Central

    2014-01-01

    Background Two major hurdles for successful production of second-generation bioethanol are the presence of inhibitory compounds in lignocellulosic media, and the fact that Saccharomyces cerevisiae cannot naturally utilise pentoses. There are recombinant yeast strains that address both of these issues, but co-utilisation of glucose and xylose is still an issue that needs to be resolved. A non-recombinant way to increase yeast tolerance to hydrolysates is by encapsulation of the yeast. This can be explained by concentration gradients occuring in the cell pellet inside the capsule. In the current study, we hypothesised that encapsulation might also lead to improved simultaneous utilisation of hexoses and pentoses because of such sugar concentration gradients. Results In silico simulations of encapsulated yeast showed that the presence of concentration gradients of inhibitors can explain the improved inhibitor tolerance of encapsulated yeast. Simulations also showed pronounced concentration gradients of sugars, which resulted in simultaneous xylose and glucose consumption and a steady state xylose consumption rate up to 220-fold higher than that found in suspension culture. To validate the results experimentally, a xylose-utilising S. cerevisiae strain, CEN.PK XXX, was constructed and encapsulated in semi-permeable alginate-chitosan liquid core gel capsules. In defined media, encapsulation not only increased the tolerance of the yeast to inhibitors, but also promoted simultaneous utilisation of glucose and xylose. Encapsulation of the yeast resulted in consumption of at least 50% more xylose compared with suspended cells over 96-hour fermentations in medium containing both sugars. The higher consumption of xylose led to final ethanol titres that were approximately 15% higher. In an inhibitory dilute acid spruce hydrolysate, freely suspended yeast cells consumed the sugars in a sequential manner after a long lag phase, whereas no lag phase was observed for the encapsulated yeast, and glucose, mannose, galactose and xylose were utilised in parallel from the beginning of the cultivation. Conclusions Encapsulation of xylose-fermenting S. cerevisiae leads to improved simultaneous and efficient utilisation of several sugars, which are utilised sequentially by suspended cells. The greatest improvement is obtained in inhibitory media. These findings show that encapsulation is a promising option for production of second-generation bioethanol. PMID:25050138

  10. Biometric gonioscopy and the effects of age, race, and sex on the anterior chamber angle

    PubMed Central

    Congdon, N G; Foster, P J; Wamsley, S; Gutmark, J; Nolan, W; Seah, S K; Johnson, G J; Broman, A T

    2002-01-01

    Aim: To utilise a novel method for making measurements in the anterior chamber in order to compare the anterior chamber angles of people of European, African, and east Asian descent aged 40 years and over. Methods: A cross sectional study on 15 people of each sex from each decade from the 40s to the 70s, from each of three racial groups—black, white, and Chinese Singaporeans. Biometric gonioscopy (BG) utilises a slit lamp mounted reticule to make measurements from the apparent iris insertion to Schwalbe's line through a Goldmann one mirror goniolens. The main outcome measures were BG measurements of the anterior chamber angle as detailed above. Results: There was no significant difference in angle measurement between black, white, and Chinese races in this study. However, at younger ages people of Chinese race appeared to have deeper angles than white or black people, whereas the angles of older Chinese were significantly narrower (p = 0.004 for the difference in slope of BG by age between Chinese and both black and white people). Conclusion: The failure to detect a difference in angle measurements between these groups was surprising, given the much higher prevalence of angle closure among Chinese. It appears that the overall apparent similarity of BG means between Chinese and Western populations may mask very different trends with age. The apparently more rapid decline in angle width measurements with age among Chinese may be due to the higher prevalence of cataract or “creeping angle closure.” However, longitudinal inferences from cross sectional data are problematic, and this may represent a cohort phenomenon caused by the increasing prevalence of myopia in the younger Singaporean population. PMID:11801496

  11. Trends of CT utilisation in an emergency department in Taiwan: a 5-year retrospective study.

    PubMed

    Hu, Sung-Yuan; Hsieh, Ming-Shun; Lin, Meng-Yu; Hsu, Chiann-Yi; Lin, Tzu-Chieh; How, Chorng-Kuang; Wang, Chen-Yu; Tsai, Jeffrey Che-Hung; Wu, Yu-Hui; Chang, Yan-Zin

    2016-06-08

    To investigate the association between the trends of CT utilisation in an emergency department (ED) and changes in clinical imaging practice and patients' disposition. A hospital-based retrospective observational study of a public 1520-bed referral medical centre in Taiwan. Adult ED visits (aged ≥18 years) during 2009-2013, with or without receiving CT, were enrolled as the study participants. For all enrolled ED visits, we retrospectively analysed: (1) demographic characteristics, (2) triage categories, (3) whether CT was performed and the type of CT scan, (4) further ED disposition, (5) ED cost and (6) ED length of stay. In all, 269 239 adult ED visits (148 613 male patients and 120 626 female patients) were collected during the 5-year study period, comprising 38 609 CT scans. CT utilisation increased from 11.10% in 2009 to 17.70% in 2013 (trend test, p<0.001). Four in 5 types of CT scan (head, chest, abdomen and miscellaneous) were increasingly utilised during the study period. Also, CT was increasingly ordered annually in all age groups. Although ED CT utilisation rates increased markedly, the annual ED visits did not actually increase. Moreover, the subsequent admission rate, after receiving ED CT, declined (59.9% in 2009 to 48.2% in 2013). ED CT utilisation rates increased significantly during 2009-2013. Emergency physicians may be using CT for non-emergent studies in the ED. Further investigation is needed to determine whether increasing CT utilisation is efficient and cost-effective. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  12. Determinants of utilisation differences for cancer medicines in Belgium, Scotland and Sweden.

    PubMed

    Ferrario, Alessandra

    2017-12-01

    Little comparative evidence is available on utilisation of cancer medicines in different countries and its determinants. The aim of this study was to develop a statistical model to test the correlation between utilisation and possible determinants in selected European countries. A sample of 31 medicines for cancer treatment that obtained EU-wide marketing authorisation between 2000 and 2012 was selected. Annual data on medicines' utilisation covering the in- and out-patient public sectors were obtained from national authorities between 2008 and 2013. Possible determinants of utilisation were extracted from HTA reports and complemented by contacts with key informants. A longitudinal mixed effect model was fitted to test possible determinants of medicines utilisation in Belgium, Scotland and Sweden. In the all-country model, the number of indications reimbursed positively correlated with increased consumption of medicines [one indication 2.6, 95% CI (1.8-3.6); two indications 2.4, 95% CI (1.4-4.3); three indications 4.9, 95% CI (2.2-10.9); all P < 0.01], years since EU-wide marketing authorisation [1.2, 95% CI (1.02-1.4); p < 0.05], price per DDD [0.9, 95% CI (0.998-0.999), P < 0.01], and Prescrire rating [0.5, 95% CI (0.3-0.9), P < 0.05] after adjusting for time and other covariates. In this study, the most important correlates of increased utilisation in a sample of cancer medicines introduced in the past 15 years were: medicines coverage and time since marketing authorisation. Prices had a negative effect on consumption in Belgium and Sweden. The positive impact of financial MEAs in Scotland suggests that the latter may remove the regressive effect of list prices on consumption.

  13. Health services utilisation disparities between English speaking and non-English speaking background Australian infants

    PubMed Central

    2010-01-01

    Background To examine the differences in health services utilisation and the associated risk factors between infants from non-English speaking background (NESB) and English speaking background (ESB) within Australia. Methods We analysed data from a national representative longitudinal study, the Longitudinal Study of Australian Children (LSAC) which started in 2004. We used survey logistic regression coupled with survey multiple linear regression to examine the factors associated with health services utilisation. Results Similar health status was observed between the two groups. In comparison to ESB infants, NESB infants were significantly less likely to use the following health services: maternal and child health centres or help lines (odds ratio [OR] 0.56; 95% confidence intervals [CI], 0.40-0.79); maternal and child health nurse visits (OR 0.68; 95% CI, 0.49-0.95); general practitioners (GPs) (OR 0.58; 95% CI, 0.40-0.83); and hospital outpatient clinics (OR 0.54; 95% CI, 0.31-0.93). Multivariate analysis results showed that the disparities could not be fully explained by the socioeconomic status and language barriers. The association between English proficiency and the service utilised was absent once the NESB was taken into account. Maternal characteristics, family size and income, private health insurance and region of residence were the key factors associated with health services utilisation. Conclusions NESB infants accessed significantly less of the four most frequently used health services compared with ESB infants. Maternal characteristics and family socioeconomic status were linked to health services utilisation. The gaps in health services utilisation between NESB and ESB infants with regard to the use of maternal and child health centres or phone help, maternal and child health nurse visits, GPs and paediatricians require appropriate policy attentions and interventions. PMID:20374663

  14. Utilisation of primary total knee joint replacements across socioeconomic status in the Barwon Statistical Division, Australia, 2006-2007: a cross-sectional study.

    PubMed

    Brennan, Sharon Lee; Stanford, Tyman; Wluka, Anita E; Page, Richard S; Graves, Stephen E; Kotowicz, Mark A; Nicholson, Geoffrey C; Pasco, Julie A

    2012-01-01

    There are few Australian data that examine the association between total knee joint replacement (TKR) utilisation and socioeconomic status (SES). This study examined TKR surgeries with a diagnosis of osteoarthritis (OA) performed for residents of Barwon Statistical Division (BSD) for 2006-2007. Cross-sectional. BSD, South-eastern Victoria, Australia All patients who underwent a TKR for OA, 2006-2007, and whose residential postcode was identified as within the BSD of Australia, and for whom SES data were available, were eligible for inclusion. Primary TKR data ascertained from the Australian Orthopaedic Association National Joint Replacement Registry. Residential addresses were matched with the Australian Bureau of Statistics census data, and the Index of Relative Socioeconomic Disadvantage was used to determine SES, categorised into quintiles whereby quintile 1 indicated the most disadvantaged and quintile 5 the least disadvantaged. Age-specific and sex-specific rates of TKR utilisation per 1000 person-years were reported for 10-year age bands. Females accounted for 62.7% of the 691 primary TKR surgeries performed during 2006-2007. The greatest utilisation rates of TKR in males was 7.6 observed in those aged >79 years, and in 10.2 in females observed in those aged 70-79 years. An increase in TKR was observed for males in SES quintile four compared to quintile 1 in which the lowest utilisation which was observed (p=0.04). No differences were observed in females across SES quintiles. Further investigation is warranted on a larger scale to examine the role that SES may play in TKR utilisation, and to determine whether any social disparities in TKR utilisation reflect health system biases or geographic differences.

  15. Modular operation of membrane bioreactors for higher hydraulic capacity utilisation.

    PubMed

    Veltmann, K; Palmowski, L M; Pinnekamp, J

    2011-01-01

    Using data from 6 full-scale municipal membrane bioreactors (MBR) in Germany the hydraulic capacity utilisation and specific energy consumption were studied and their connexion shown. The average hydraulic capacity utilisation lies between 14% and 45%. These low values are justified by the necessity to deal with intense rain events and cater for future flow increases. However, this low hydraulic capacity utilisation leads to high specific energy consumption. The optimisation of MBR operation requires a better utilisation of MBR hydraulic capacity, particularly under consideration of the energy-intensive membrane aeration. A first approach to respond to large influent flow fluctuations consists in adjusting the number of operating modules. This is practised by most MBR operators but so far mostly with variable flux and constant membrane aeration. A second approach is the real-time adjustment of membrane aeration in line with flux variations. This adjustment is not permitted under current manufacturers' warranty conditions. A further opportunity is a discontinuous operation, in which filtration takes place over short periods at high flux and energy for membrane aeration is saved during filtration pauses. The integration of a buffer volume is thereby indispensable. Overall a modular design with small units, which can be activated/ inactivated according to the influent flow and always operate under optimum conditions, enables a better utilisation of MBR hydraulic capacity and forms a solid base to reduce MBR energy demand.

  16. African American women's preventative care usage: the role of social support and racial experiences and attitudes.

    PubMed

    Pullen, Erin; Perry, Brea; Oser, Carrie

    2014-09-01

    Research suggests that African Americans are less likely to utilise preventative care services than Americans of European descent, and that these patterns may contribute to racial health disparities in the United States. Despite the persistence of inequalities in preventative care utilisation, culturally relevant factors influencing the use of these gateway health services have been understudied among marginalised groups. Using a stratified sample of 205 low-income African American women, this research examines the predictors of receiving a physical exam, with a particular emphasis on how differing levels of social support from friend and family networks and experiences of racial discrimination and cultural mistrust shape utilisation. The findings underscore the importance of traditional predictors of utilisation, including insurance status and having a usual physician. However, they also indicate that supportive ties to friendship networks are associated with higher predicted rates of having an annual physical exam, while social support from family and sentiments of cultural mistrust are associated with lower rates of utilisation. Broadly, the findings indicate that even as traditional predictors of help-seeking become less relevant, it will be critical to explore how variations in discrimination experiences and social relationships across marginalised groups drive patterns of preventative care utilisation. © 2014 The Authors. Sociology of Health & Illness © 2014 Foundation for the Sociology of Health & Illness/John Wiley & Sons Ltd.

  17. Metabolic specialisation on preferred prey and constraints in the utilisation of alternative prey in an ant-eating spider.

    PubMed

    Líznarová, Eva; Pekár, Stano

    2016-10-01

    Trophic specialists are expected to possess adaptations that increase the efficiency of handling preferred prey. Such adaptations may constrain the ability to utilise alternative prey. Here we tested whether the ant-eating spider Euryopis episinoides possesses metabolic specialisations with increased efficiency in utilising preferred prey and decreased efficiency in utilising alternative prey. In addition, we investigated the contribution of genetic variation via maternal effects. We reared E. episinoides spiders from the first instar on two different diets, either ants (preferred prey) or fruit flies (alternative prey). Spider survival rate and increases in body mass were significantly higher on the ant diet. The total development time did not differ between diet groups, nor did the number of egg sacs per female or the incubation period. However, the number of eggs per egg sac and hatching success were higher on the ant diet. There was a genetic variation in several offspring traits. Our data support the hypothesis that stenophagous ant-eating E. episinoides have a metabolic specialisation on ant utilisation indicated by higher efficiency in utilising ants than fruit flies. While most individuals of E. episinoides were able to capture fruit flies, only very few spiders were able to develop and reproduce on a pure fruit fly diet, suggesting the existence of within-species genetic variation regarding the tolerance to alternative prey. Copyright © 2016 Elsevier GmbH. All rights reserved.

  18. Stoichiometric modelling of assimilatory and dissimilatory biomass utilisation in a microbial community

    PubMed Central

    Hunt, Kristopher A.; Jennings, Ryan deM.; Inskeep, William P.; Carlson, Ross P.

    2017-01-01

    Summary Assimilatory and dissimilatory utilisation of autotroph biomass by heterotrophs is a fundamental mechanism for the transfer of nutrients and energy across trophic levels. Metagenome data from a tractable, thermoacidophilic microbial community in Yellowstone National Park was used to build an in silico model to study heterotrophic utilisation of autotroph biomass using elementary flux mode analysis and flux balance analysis. Assimilatory and dissimilatory biomass utilisation was investigated using 29 forms of biomass-derived dissolved organic carbon (DOC) including individual monomer pools, individual macromolecular pools and aggregate biomass. The simulations identified ecologically competitive strategies for utilizing DOC under conditions of varying electron donor, electron acceptor or enzyme limitation. The simulated growth environment affected which form of DOC was the most competitive use of nutrients; for instance, oxygen limitation favoured utilisation of less reduced and fermentable DOC while carbon-limited environments favoured more reduced DOC. Additionally, metabolism was studied considering two encompassing metabolic strategies: simultaneous versus sequential use of DOC. Results of this study bound the transfer of nutrients and energy through microbial food webs, providing a quantitative foundation relevant to most microbial ecosystems. PMID:27387069

  19. An approach to assessing stochastic radiogenic risk in medical imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wolbarst, Anthony B.; Hendee, William R.; Department of Radiology, Mayo Clinic, Rochester, Minnesota 55901

    2011-12-15

    Purpose: This letter suggests a formalism, the medical effective dose (MED), that is suitable for assessing stochastic radiogenic risks in diagnostic medical procedures. Methods: The MED is derived from radiobiological and probabilistic first principals, including: (1) The independence of radiation-induced biological effects in neighboring voxels at low doses; (2) the linear no-threshold assumption for stochastic radiation injury (although other dose-response relationships could be incorporated, instead); (3) the best human radiation dose-response data currently available; and (4) the built-in possibility that the carcinogenic risk to an irradiated organ may depend on its volume. The MED involves a dose-risk summation over irradiatedmore » voxels at high spatial resolution; it reduces to the traditional effective dose when every organ is irradiated uniformly and when the dependence of risk on organ volumes is ignored. Standard relative-risk tissue weighting factors can be used with the MED approach until more refined data become available. Results: The MED is intended for clinical and phantom dosimetry, and it provides an estimate of overall relative radiogenic stochastic risk for any given dose distribution. A result of the MED derivation is that the stochastic risk may increase with the volume of tissue (i.e., the number of cells) irradiated, a feature that can be activated when forthcoming radiobiological research warrants it. In this regard, the MED resembles neither the standard effective dose (E) nor the CT dose index (CTDI), but it is somewhat like the CT dose-length product (DLP). Conclusions: The MED is a novel, probabilistically and biologically based means of estimating stochastic-risk-weighted doses associated with medical imaging. Built in, ab initio, is the ability to link radiogenic risk to organ volume and other clinical factors. It is straightforward to implement when medical dose distributions are available, provided that one is content, for the time being, to accept the relative tissue weighting factors published by the International Commission of Radiological Protection (ICRP). It requires no new radiobiological data and avoids major problems encountered by the E, CTDI, and CT-E formalisms. It makes possible relative inter-patient dosimetry, and also realistic intercomparisons of stochastic risks from different protocols that yield images of comparable quality.« less

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dr. Anthony C. James; Stacey L. McCord

    The National Radiobiology Archives (NRA) are an archival program, started in 1989, to collect, organize and maintain data, laboratory notebooks, and animal tissue specimens from government (Department of Energy and its predecessor agencies) sponsored radiobiology life-span animal studies. These unique records, histopathology slides and paraffin embedded tissue blocks are maintained in a central facility and are available for further research study. The materials include electronic and paper records for each of more than 6,000 life-span-observations on dogs as well as details of major studies involving nearly 30,000 mice. Although these studies were performed over many years and at different laboratoriesmore » with differing data management systems, the NRA has translated them into a standardized set of relational database tables. These can be distributed to interested individuals on written request. Specific Aims are: (1) To Maintain the Archive of Written Records from the Animal Experiments - The USTUR continued to maintain the NRA archives which consist of approximately 175 storage boxes containing laboratory notebooks, animal exposure records, animal pathologic records, and radiographs. These were stored in a 6,000 square foot leased facility in Richland, WA. Additionally, through a collaboration with Pacific Northwest National Laboratory's (PNNL) Low Dose Program, many of these records were scanned into digital files. These totaled 34 GB of data, which are saved in 2,407 separate PDF files that are organized by box number and animal identification number. (2) To Maintain the Archive of Animal Tissues at Washington State University - The USTUR continued to house the NRA dog tissue collection in the leased facility. The NRA tissue collection consisted of pathology slides and tissue blocks. Approximately 25% of the laboratory facility was dedicated to the storage of the NRA materials. (3) To Organize the Datasets of These Animals in the Context of Other Datasets so That They Can be Used by the Scientific Community at Large - As was reported in the FY2009 NRA progress report, Dr. Chuck Watson (NRA Database Consultant) completed his service as the US representative on the European Radiobiological Archives (ERA) Advisory Board during FY2009. Unfortunately, due to the lack of financial support during FY2010, the NRA was not able to make further contributions to the ERA's efforts.« less

  1. Radiobiological Optimization of Combination Radiopharmaceutical Therapy Applied to Myeloablative Treatment of Non-Hodgkin’s Lymphoma

    PubMed Central

    Hobbs, Robert F; Wahl, Richard L; Frey, Eric C; Kasamon, Yvette; Song, Hong; Huang, Peng; Jones, Richard J; Sgouros, George

    2014-01-01

    Combination treatment is a hallmark of cancer therapy. Although the rationale for combination radiopharmaceutical therapy was described in the mid ‘90s, such treatment strategies have only been implemented clinically recently, and without a rigorous methodology for treatment optimization. Radiobiological and quantitative imaging-based dosimetry tools are now available that enable rational implementation of combined targeted radiopharmaceutical therapy. Optimal implementation should simultaneously account for radiobiological normal organ tolerance while optimizing the ratio of two different radiopharmaceuticals required to maximize tumor control. We have developed such a methodology and applied it to hypothetical myeloablative treatment of non-hodgkin’s lymphoma (NHL) patients using 131I-tositumomab and 90Y-ibritumomab tiuxetan. Methods The range of potential administered activities (AA) is limited by the normal organ maximum tolerated biologic effective doses (MTBEDs) arising from the combined radiopharmaceuticals. Dose limiting normal organs are expected to be the lungs for 131I-tositumomab and the liver for 90Y-ibritumomab tiuxetan in myeloablative NHL treatment regimens. By plotting the limiting normal organ constraints as a function of the AAs and calculating tumor biological effective dose (BED) along the normal organ MTBED limits, the optimal combination of activities is obtained. The model was tested using previously acquired patient normal organ and tumor kinetic data and MTBED values taken from the literature. Results The average AA values based solely on normal organ constraints was (19.0 ± 8.2) GBq with a range of 3.9 – 36.9 GBq for 131I-tositumomab, and (2.77 ± 1.64) GBq with a range of 0.42 – 7.54 GBq for 90Y-ibritumomab tiuxetan. Tumor BED optimization results were calculated and plotted as a function of AA for 5 different cases, established using patient normal organ kinetics for the two radiopharmaceuticals. Results included AA ranges which would deliver 95 % of the maximum tumor BED, which allows for informed inclusion of clinical considerations, such as a maximum allowable 131I administration. Conclusions A rational approach for combination radiopharmaceutical treatment has been developed within the framework of a proven 3-dimensional personalized dosimetry software, 3D-RD, and applied to the myeloablative treatment of NHL. We anticipate combined radioisotope therapy will ultimately supplant single radioisotope therapy, much as combination chemotherapy has substantially replaced single agent chemotherapy. PMID:23918734

  2. Integration of radiobiological modeling and indices in comparative plan evaluation: A study comparing VMAT and 3D-CRT in patients with NSCLC.

    PubMed

    Roy, Soumyajit; Badragan, Iulian; Ahmed, Sheikh Nisar; Sia, Michael; Singh, Jorawur; Bahl, Gaurav

    2018-03-01

    The purpose of this article was to generate an algorithm to calculate radiobiological endpoints and composite indices and use them to compare volumetric modulated arc therapy (VMAT) and 3-dimensional conformal radiation therapy (3D-CRT) techniques in patients with locally advanced non-small cell lung cancer. The study included 25 patients with locally advanced non-small cell lung cancer treated with 3D-CRT at our center between January 1, 2010, and December 31, 2014. The planner generated VMAT plans using clones of the original computed tomography scans and regions of interest volumes, which did not include the original 3D plans. Both 3D-CRT and VMAT plans were generated using the same dose-volume constraint worksheet. The dose-volume histogram parameters for planning target volume and relevant organs at risk (OAR) were reviewed. The calculation engine was written in the R programming language; the user interface was developed with the "shiny" R Web library. Dose-volume histogram data were imported into the calculation engine and tumor control probability (TCP), normal tissue complication probability (NTCP), composite cardiopulmonary toxicity index (CPTI), morbidity index: MI = ∑ j = 1 #ofrelevantOARs (w j  ∗ NTCP j ), uncomplicated TCP (UTCP=TCP∗∏k=1#ofOARs1-NTCP K 100, and therapeutic gain (TG): ie, TG = TCP ∗ (100 - MI) were calculated. TCP was better with 3D-CRT (12.62% vs 11.71%, P < .001), whereas VMAT demonstrated superior NTCP esophagus (4.45% vs 7.39%, P = .02). NTCP spinal cord (0.001% vs 0.009%, P = .001), and NTCP heart/perfusion defect (44.57% vs 56.42%, P = .016). There was no difference in NTCP lung (6.27% vs 7.62%, P = .221) and NTCP heart/pericarditis (0.001% vs 0.15%, P = .129) between 2 techniques. VMAT showed substantial improvement in morbidity index (11.06% vs. 14.31%, P = 0.01), CPTI (47.59% vs 59.41%, P = .03), TG (P = .035), and trend toward superiority in UTCP (5.89 vs 4.75, P=.057). The study highlights the utility of the radiobiological algorithm and summary indices in comparative plan evaluation and demonstrates benefits of VMAT over 3D-CRT. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. MO-A-BRC-00: TG167: Clinical Recommendations for Innovative Brachytherapy Devices and Applicators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Although a multicenter, Phase III, prospective, randomized trial is the gold standard for evidence-based medicine, it is rarely used to evaluate innovative radiotherapy devices because of many practical and ethical reasons. It is usually sufficient to compare the dose distributions and dose rates for determining equivalence of the innovative device to an existing one. Thus, quantitative evaluation of the dosimetric characteristics of an innovative brachytherapy device or application is a critical part in which physicists are actively involved. The physicist’s role, along with physician colleagues, in this process is highlighted for innovative products or applications and includes evaluation of 1)more » dosimetric considerations for clinical implementation (including calibrations, dose calculations, and radiobiological aspects) to comply with existing societal dosimetric prerequisites for sources in routine clinical use, 2) risks and benefits from regulatory and safety perspectives, and 3) resource assessment and preparedness. Further, calibration methods should be traceable to a primary standards dosimetry laboratory such as NIST in the U.S. or to other primary standards dosimetry laboratory located elsewhere. Clinical users should follow standards as approved by their country’s regulatory agencies that approved such a brachytherapy device. Integration of this system into the medical source calibration infrastructure of secondary standard dosimetry laboratories such as the ADCLs is encouraged before a source is introduced into widespread routine clinical use. The AAPM and GEC-ESTRO have developed guidelines for the safe and consistent application of brachytherapy using innovative brachytherapy devices and applications. The current report covers regulatory approvals, calibration, dose calculations, radiobiological issues, and overall safety concerns that should be addressed during the commissioning stage preceding clinical use. These guidelines are based on review of requirements of the U.S. NRC, FDA, Department of Transportation, International Electrotechnical Commission Medical Electrical Equipment Standard 60601, European Commission for CE Marking, and institutional review boards and radiation safety committees. Learning Objectives: Understand the necessary dosimetric considerations for clinical implementation (including calibrations, dose calculations, and radiobiological aspects) to comply with existing societal dosimetric prerequisites for sources in routine clinical use. Evaluate risks and benefits from regulatory and safety perspectives. Identify necessary resources and create a plan for clinical introduction of innovative brachytherapy device or applications. Consultant for Theragenics Corp.; R. Nath, Consultant to Theragenics Corp.« less

  4. WE-F-304-00: Outcomes of Hypofractionated Treatments - Results of the WGSBRT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Stereotactic Body Radiation Therapy (SBRT) was introduced clinically more than twenty years ago, and many subsequent publications have reported safety and efficacy data. The AAPM Working Group on Biological Effects of Hypofractionated Radiotherapy/SBRT (WGSBRT) extracted published treatment outcomes data from extensive literature searches to summarize and construct tumor control probability (TCP) and normal tissue complication probability (NTCP) models for six anatomical regions: Cranial, Head and Neck, Thoracic, Abdominal, Pelvic, and Spinal. In this session, we present the WGSBRT’s work for cranial sites, and recurrent head and neck cancer. From literature-based data and associated models, guidelines to aid with safe andmore » effective hypofractionated radiotherapy treatment are being determined. Further, the ability of existing and proposed radiobiological models to fit these data is considered as to the ability to distinguish between the linear-quadratic and alternative radiobiological models such as secondary cell death from vascular damage, immunogenic, or bystander effects. Where appropriate, specific model parameters are estimated. As described in “The lessons of QUANTEC,” (1), lack of adequate reporting standards continues to limit the amount of useful quantitative information that can be extracted from peer-reviewed publications. Recommendations regarding reporting standards are considered, to enable such reviews to achieve more complete characterization of clinical outcomes. 1 Jackson A, Marks LB, Bentzen SM, Eisbruch A, Yorke ED, Ten Haken RK, Constine LS, Deasy JO. The lessons of QUANTEC: recommendations for reporting and gathering data on dose-volume dependencies of treatment outcome. Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S155–60. Learning Objectives: Describe the techniques, types of cancer and dose schedules used in treating recurrent H&N cancers with SBRT List the radiobiological models that compete with the linear-quadratic model in explaining the results of hypofractionated RT Describe the dose/volume metrics that are considered safe in SBRT treatment of tumors near the optic structures. Discuss the efficacy of hypofractionation and dosing schedules used in treating vestibular schwannomas Identify some difficulties in modeling TCP and NTCP for cranial tumors treated with hypofractionation. One moderator, Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and can analyze some of this data. No others have relevant conflicts of interest.« less

  5. WE-F-304-05: Cranial TCP/NTCP Modeling Insights and Caveats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    El Naqa, I.

    Stereotactic Body Radiation Therapy (SBRT) was introduced clinically more than twenty years ago, and many subsequent publications have reported safety and efficacy data. The AAPM Working Group on Biological Effects of Hypofractionated Radiotherapy/SBRT (WGSBRT) extracted published treatment outcomes data from extensive literature searches to summarize and construct tumor control probability (TCP) and normal tissue complication probability (NTCP) models for six anatomical regions: Cranial, Head and Neck, Thoracic, Abdominal, Pelvic, and Spinal. In this session, we present the WGSBRT’s work for cranial sites, and recurrent head and neck cancer. From literature-based data and associated models, guidelines to aid with safe andmore » effective hypofractionated radiotherapy treatment are being determined. Further, the ability of existing and proposed radiobiological models to fit these data is considered as to the ability to distinguish between the linear-quadratic and alternative radiobiological models such as secondary cell death from vascular damage, immunogenic, or bystander effects. Where appropriate, specific model parameters are estimated. As described in “The lessons of QUANTEC,” (1), lack of adequate reporting standards continues to limit the amount of useful quantitative information that can be extracted from peer-reviewed publications. Recommendations regarding reporting standards are considered, to enable such reviews to achieve more complete characterization of clinical outcomes. 1 Jackson A, Marks LB, Bentzen SM, Eisbruch A, Yorke ED, Ten Haken RK, Constine LS, Deasy JO. The lessons of QUANTEC: recommendations for reporting and gathering data on dose-volume dependencies of treatment outcome. Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S155–60. Learning Objectives: Describe the techniques, types of cancer and dose schedules used in treating recurrent H&N cancers with SBRT List the radiobiological models that compete with the linear-quadratic model in explaining the results of hypofractionated RT Describe the dose/volume metrics that are considered safe in SBRT treatment of tumors near the optic structures. Discuss the efficacy of hypofractionation and dosing schedules used in treating vestibular schwannomas Identify some difficulties in modeling TCP and NTCP for cranial tumors treated with hypofractionation. One moderator, Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and can analyze some of this data. No others have relevant conflicts of interest.« less

  6. MO-A-BRC-02: TG167 Report - Detailed Description

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rivard, M.

    Although a multicenter, Phase III, prospective, randomized trial is the gold standard for evidence-based medicine, it is rarely used to evaluate innovative radiotherapy devices because of many practical and ethical reasons. It is usually sufficient to compare the dose distributions and dose rates for determining equivalence of the innovative device to an existing one. Thus, quantitative evaluation of the dosimetric characteristics of an innovative brachytherapy device or application is a critical part in which physicists are actively involved. The physicist’s role, along with physician colleagues, in this process is highlighted for innovative products or applications and includes evaluation of 1)more » dosimetric considerations for clinical implementation (including calibrations, dose calculations, and radiobiological aspects) to comply with existing societal dosimetric prerequisites for sources in routine clinical use, 2) risks and benefits from regulatory and safety perspectives, and 3) resource assessment and preparedness. Further, calibration methods should be traceable to a primary standards dosimetry laboratory such as NIST in the U.S. or to other primary standards dosimetry laboratory located elsewhere. Clinical users should follow standards as approved by their country’s regulatory agencies that approved such a brachytherapy device. Integration of this system into the medical source calibration infrastructure of secondary standard dosimetry laboratories such as the ADCLs is encouraged before a source is introduced into widespread routine clinical use. The AAPM and GEC-ESTRO have developed guidelines for the safe and consistent application of brachytherapy using innovative brachytherapy devices and applications. The current report covers regulatory approvals, calibration, dose calculations, radiobiological issues, and overall safety concerns that should be addressed during the commissioning stage preceding clinical use. These guidelines are based on review of requirements of the U.S. NRC, FDA, Department of Transportation, International Electrotechnical Commission Medical Electrical Equipment Standard 60601, European Commission for CE Marking, and institutional review boards and radiation safety committees. Learning Objectives: Understand the necessary dosimetric considerations for clinical implementation (including calibrations, dose calculations, and radiobiological aspects) to comply with existing societal dosimetric prerequisites for sources in routine clinical use. Evaluate risks and benefits from regulatory and safety perspectives. Identify necessary resources and create a plan for clinical introduction of innovative brachytherapy device or applications. Consultant for Theragenics Corp.; R. Nath, Consultant to Theragenics Corp.« less

  7. WE-F-304-03: Optic Nerve/Chiasm Hypofractionated SRS/SRT Dose Tolerance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Milano, M.

    Stereotactic Body Radiation Therapy (SBRT) was introduced clinically more than twenty years ago, and many subsequent publications have reported safety and efficacy data. The AAPM Working Group on Biological Effects of Hypofractionated Radiotherapy/SBRT (WGSBRT) extracted published treatment outcomes data from extensive literature searches to summarize and construct tumor control probability (TCP) and normal tissue complication probability (NTCP) models for six anatomical regions: Cranial, Head and Neck, Thoracic, Abdominal, Pelvic, and Spinal. In this session, we present the WGSBRT’s work for cranial sites, and recurrent head and neck cancer. From literature-based data and associated models, guidelines to aid with safe andmore » effective hypofractionated radiotherapy treatment are being determined. Further, the ability of existing and proposed radiobiological models to fit these data is considered as to the ability to distinguish between the linear-quadratic and alternative radiobiological models such as secondary cell death from vascular damage, immunogenic, or bystander effects. Where appropriate, specific model parameters are estimated. As described in “The lessons of QUANTEC,” (1), lack of adequate reporting standards continues to limit the amount of useful quantitative information that can be extracted from peer-reviewed publications. Recommendations regarding reporting standards are considered, to enable such reviews to achieve more complete characterization of clinical outcomes. 1 Jackson A, Marks LB, Bentzen SM, Eisbruch A, Yorke ED, Ten Haken RK, Constine LS, Deasy JO. The lessons of QUANTEC: recommendations for reporting and gathering data on dose-volume dependencies of treatment outcome. Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S155–60. Learning Objectives: Describe the techniques, types of cancer and dose schedules used in treating recurrent H&N cancers with SBRT List the radiobiological models that compete with the linear-quadratic model in explaining the results of hypofractionated RT Describe the dose/volume metrics that are considered safe in SBRT treatment of tumors near the optic structures. Discuss the efficacy of hypofractionation and dosing schedules used in treating vestibular schwannomas Identify some difficulties in modeling TCP and NTCP for cranial tumors treated with hypofractionation. One moderator, Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and can analyze some of this data. No others have relevant conflicts of interest.« less

  8. WE-F-304-04: Radiosurgery for Vestibular Schwannomas: Tumor Control Probability Analyses and Recommended Reporting Standards

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Soltys, S.

    Stereotactic Body Radiation Therapy (SBRT) was introduced clinically more than twenty years ago, and many subsequent publications have reported safety and efficacy data. The AAPM Working Group on Biological Effects of Hypofractionated Radiotherapy/SBRT (WGSBRT) extracted published treatment outcomes data from extensive literature searches to summarize and construct tumor control probability (TCP) and normal tissue complication probability (NTCP) models for six anatomical regions: Cranial, Head and Neck, Thoracic, Abdominal, Pelvic, and Spinal. In this session, we present the WGSBRT’s work for cranial sites, and recurrent head and neck cancer. From literature-based data and associated models, guidelines to aid with safe andmore » effective hypofractionated radiotherapy treatment are being determined. Further, the ability of existing and proposed radiobiological models to fit these data is considered as to the ability to distinguish between the linear-quadratic and alternative radiobiological models such as secondary cell death from vascular damage, immunogenic, or bystander effects. Where appropriate, specific model parameters are estimated. As described in “The lessons of QUANTEC,” (1), lack of adequate reporting standards continues to limit the amount of useful quantitative information that can be extracted from peer-reviewed publications. Recommendations regarding reporting standards are considered, to enable such reviews to achieve more complete characterization of clinical outcomes. 1 Jackson A, Marks LB, Bentzen SM, Eisbruch A, Yorke ED, Ten Haken RK, Constine LS, Deasy JO. The lessons of QUANTEC: recommendations for reporting and gathering data on dose-volume dependencies of treatment outcome. Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S155–60. Learning Objectives: Describe the techniques, types of cancer and dose schedules used in treating recurrent H&N cancers with SBRT List the radiobiological models that compete with the linear-quadratic model in explaining the results of hypofractionated RT Describe the dose/volume metrics that are considered safe in SBRT treatment of tumors near the optic structures. Discuss the efficacy of hypofractionation and dosing schedules used in treating vestibular schwannomas Identify some difficulties in modeling TCP and NTCP for cranial tumors treated with hypofractionation. One moderator, Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and can analyze some of this data. No others have relevant conflicts of interest.« less

  9. WE-F-304-02: Recurrent HNC Treated with SBRT: TCP-Based Outcome Estimates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clump, D.

    Stereotactic Body Radiation Therapy (SBRT) was introduced clinically more than twenty years ago, and many subsequent publications have reported safety and efficacy data. The AAPM Working Group on Biological Effects of Hypofractionated Radiotherapy/SBRT (WGSBRT) extracted published treatment outcomes data from extensive literature searches to summarize and construct tumor control probability (TCP) and normal tissue complication probability (NTCP) models for six anatomical regions: Cranial, Head and Neck, Thoracic, Abdominal, Pelvic, and Spinal. In this session, we present the WGSBRT’s work for cranial sites, and recurrent head and neck cancer. From literature-based data and associated models, guidelines to aid with safe andmore » effective hypofractionated radiotherapy treatment are being determined. Further, the ability of existing and proposed radiobiological models to fit these data is considered as to the ability to distinguish between the linear-quadratic and alternative radiobiological models such as secondary cell death from vascular damage, immunogenic, or bystander effects. Where appropriate, specific model parameters are estimated. As described in “The lessons of QUANTEC,” (1), lack of adequate reporting standards continues to limit the amount of useful quantitative information that can be extracted from peer-reviewed publications. Recommendations regarding reporting standards are considered, to enable such reviews to achieve more complete characterization of clinical outcomes. 1 Jackson A, Marks LB, Bentzen SM, Eisbruch A, Yorke ED, Ten Haken RK, Constine LS, Deasy JO. The lessons of QUANTEC: recommendations for reporting and gathering data on dose-volume dependencies of treatment outcome. Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S155–60. Learning Objectives: Describe the techniques, types of cancer and dose schedules used in treating recurrent H&N cancers with SBRT List the radiobiological models that compete with the linear-quadratic model in explaining the results of hypofractionated RT Describe the dose/volume metrics that are considered safe in SBRT treatment of tumors near the optic structures. Discuss the efficacy of hypofractionation and dosing schedules used in treating vestibular schwannomas Identify some difficulties in modeling TCP and NTCP for cranial tumors treated with hypofractionation. One moderator, Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and can analyze some of this data. No others have relevant conflicts of interest.« less

  10. MO-A-BRC-01: TG167 Report - Introduction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nath, R.

    Although a multicenter, Phase III, prospective, randomized trial is the gold standard for evidence-based medicine, it is rarely used to evaluate innovative radiotherapy devices because of many practical and ethical reasons. It is usually sufficient to compare the dose distributions and dose rates for determining equivalence of the innovative device to an existing one. Thus, quantitative evaluation of the dosimetric characteristics of an innovative brachytherapy device or application is a critical part in which physicists are actively involved. The physicist’s role, along with physician colleagues, in this process is highlighted for innovative products or applications and includes evaluation of 1)more » dosimetric considerations for clinical implementation (including calibrations, dose calculations, and radiobiological aspects) to comply with existing societal dosimetric prerequisites for sources in routine clinical use, 2) risks and benefits from regulatory and safety perspectives, and 3) resource assessment and preparedness. Further, calibration methods should be traceable to a primary standards dosimetry laboratory such as NIST in the U.S. or to other primary standards dosimetry laboratory located elsewhere. Clinical users should follow standards as approved by their country’s regulatory agencies that approved such a brachytherapy device. Integration of this system into the medical source calibration infrastructure of secondary standard dosimetry laboratories such as the ADCLs is encouraged before a source is introduced into widespread routine clinical use. The AAPM and GEC-ESTRO have developed guidelines for the safe and consistent application of brachytherapy using innovative brachytherapy devices and applications. The current report covers regulatory approvals, calibration, dose calculations, radiobiological issues, and overall safety concerns that should be addressed during the commissioning stage preceding clinical use. These guidelines are based on review of requirements of the U.S. NRC, FDA, Department of Transportation, International Electrotechnical Commission Medical Electrical Equipment Standard 60601, European Commission for CE Marking, and institutional review boards and radiation safety committees. Learning Objectives: Understand the necessary dosimetric considerations for clinical implementation (including calibrations, dose calculations, and radiobiological aspects) to comply with existing societal dosimetric prerequisites for sources in routine clinical use. Evaluate risks and benefits from regulatory and safety perspectives. Identify necessary resources and create a plan for clinical introduction of innovative brachytherapy device or applications. Consultant for Theragenics Corp.; R. Nath, Consultant to Theragenics Corp.« less

  11. WE-F-304-01: Overview of the Working Group On Stereotactic Body Radiation Therapy (WGSBRT)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yorke, E.

    Stereotactic Body Radiation Therapy (SBRT) was introduced clinically more than twenty years ago, and many subsequent publications have reported safety and efficacy data. The AAPM Working Group on Biological Effects of Hypofractionated Radiotherapy/SBRT (WGSBRT) extracted published treatment outcomes data from extensive literature searches to summarize and construct tumor control probability (TCP) and normal tissue complication probability (NTCP) models for six anatomical regions: Cranial, Head and Neck, Thoracic, Abdominal, Pelvic, and Spinal. In this session, we present the WGSBRT’s work for cranial sites, and recurrent head and neck cancer. From literature-based data and associated models, guidelines to aid with safe andmore » effective hypofractionated radiotherapy treatment are being determined. Further, the ability of existing and proposed radiobiological models to fit these data is considered as to the ability to distinguish between the linear-quadratic and alternative radiobiological models such as secondary cell death from vascular damage, immunogenic, or bystander effects. Where appropriate, specific model parameters are estimated. As described in “The lessons of QUANTEC,” (1), lack of adequate reporting standards continues to limit the amount of useful quantitative information that can be extracted from peer-reviewed publications. Recommendations regarding reporting standards are considered, to enable such reviews to achieve more complete characterization of clinical outcomes. 1 Jackson A, Marks LB, Bentzen SM, Eisbruch A, Yorke ED, Ten Haken RK, Constine LS, Deasy JO. The lessons of QUANTEC: recommendations for reporting and gathering data on dose-volume dependencies of treatment outcome. Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S155–60. Learning Objectives: Describe the techniques, types of cancer and dose schedules used in treating recurrent H&N cancers with SBRT List the radiobiological models that compete with the linear-quadratic model in explaining the results of hypofractionated RT Describe the dose/volume metrics that are considered safe in SBRT treatment of tumors near the optic structures. Discuss the efficacy of hypofractionation and dosing schedules used in treating vestibular schwannomas Identify some difficulties in modeling TCP and NTCP for cranial tumors treated with hypofractionation. One moderator, Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and can analyze some of this data. No others have relevant conflicts of interest.« less

  12. SU-E-T-580: On the Significance of Model Based Dosimetry for Breast and Head and Neck 192Ir HDR Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peppa, V; Pappas, E; Pantelis, E

    2015-06-15

    Purpose: To assess the dosimetric and radiobiological differences between TG43-based and model-based dosimetry in the treatment planning of {sup 192}Ir HDR brachytherapy for breast and head and neck cancer. Methods: Two cohorts of 57 Accelerated Partial Breast Irradiation (APBI) and 22 head and neck (H&N) patients with oral cavity carcinoma were studied. Dosimetry for the treatment plans was performed using the TG43 algorithm of the Oncentra Brachy v4.4 treatment planning system (TPS). Corresponding Monte Carlo (MC) simulations were performed using MCNP6 with input files automatically prepared by the BrachyGuide software tool from DICOM RT plan data. TG43 and MC datamore » were compared in terms of % dose differences, Dose Volume Histograms (DVHs) and related indices of clinical interest for the Planning Target Volume (PTV) and the Organs-At-Risk (OARs). A radiobiological analysis was also performed using the Equivalent Uniform Dose (EUD), mean survival fraction (S) and Tumor Control Probability (TCP) for the PTV, and the Normal Tissue Control Probability (N TCP) and the generalized EUD (gEUD) for the OARs. Significance testing of the observed differences performed using the Wilcoxon paired sample test. Results: Differences between TG43 and MC DVH indices, associated with the increased corresponding local % dose differences observed, were statistically significant. This is mainly attributed to their consistency however, since TG43 agrees closely with MC for the majority of DVH and radiobiological parameters in both patient cohorts. Differences varied considerably among patients only for the ipsilateral lung and ribs in the APBI cohort, with a strong correlation to target location. Conclusion: While the consistency and magnitude of differences in the majority of clinically relevant DVH indices imply that no change is needed in the treatment planning practice, individualized dosimetry improves accuracy and addresses instances of inter-patient variability observed. Research co-financed by the ESF and Greek funds through the Operational Program Education and Lifelong Learning Investing in Knowledge Society of the NSRF. Research Funding Program Aristeia. Nucletron, an Elekta company (Veenendaal, The Netherlands) is gratefully acknowledged for providing Oncentra Brachy v4.4 for research purposes.« less

  13. A systematic review of acculturation, obesity and health behaviours among migrants to high-income countries.

    PubMed

    Alidu, L; Grunfeld, E A

    2018-06-01

    Objective There is extensive evidence for weight gain among people migrating from low/middle-income to high-income countries, which may be due, in part, to acculturation factors. This review aimed to identify associations between acculturation and body weight among immigrants to high-income countries and identify if studies accounted for the role played by health behaviours. Methods A systematic literature search using keywords was performed with three databases (Medline, PsychINFO and EMBASE). The 35 studies were included that utilised quantitative methodology and presented empirical findings focused on acculturation and body weight among adult immigrants. Findings There was evidence presented across multiple studies for an association between acculturation (measured with standard measures or as duration of stay) and obesity. Most studies were cross sectional, which did not allow the exploration of drivers of change in health behaviours and weight gain. Conclusion This is the first review to examine associations between acculturation and body weight among migrants utilising both acculturation scales and proxy measures of acculturation and to examine the role of health behaviours. Evidence from this review suggests that health interventions should target first generation migrants to promote retention of their original healthy behaviours. Recent migrant groups report healthier behaviours than comparative host country populations, and therefore interventions should be promoted at the initial stages following migration to avoid uptake of unhealthy behaviours.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stewart, J; Lindsay, P; University of Toronto, Toronto

    Purpose: Recent progress in small animal radiotherapy systems has provided the foundation for delivering the heterogeneous, millimeter scale dose distributions demanded by preclinical radiobiology investigations. Despite advances in preclinical dose planning, delivery of highly heterogeneous dose distributions is constrained by the fixed collimation systems and large x-ray focal spot common in small animal radiotherapy systems. This work proposes a dual focal spot dose optimization and delivery method with a large x-ray focal spot used to deliver homogeneous dose regions and a small focal spot to paint spatially heterogeneous dose regions. Methods: Two-dimensional dose kernels were measured for a 1 mmmore » circular collimator with radiochromic film at 10 mm depth in a solid water phantom for the small and large x-ray focal spots on a recently developed small animal microirradiator. These kernels were used in an optimization framework which segmented a desired dose distribution into low- and high-spatial frequency regions for delivery by the large and small focal spot, respectively. For each region, the method determined an optimal set of stage positions and beam-on times. The method was demonstrated by optimizing a bullseye pattern consisting of 0.75 mm radius circular target and 0.5 and 1.0 mm wide rings alternating between 0 and 2 Gy. Results: Compared to a large focal spot technique, the dual focal spot technique improved the optimized dose distribution: 69.2% of the optimized dose was within 0.5 Gy of the intended dose for the large focal spot, compared to 80.6% for the dual focal spot method. The dual focal spot design required 14.0 minutes of optimization, and will require 178.3 minutes for automated delivery. Conclusion: The dual focal spot optimization and delivery framework is a novel option for delivering conformal and heterogeneous dose distributions at the preclinical level and provides a new experimental option for unique radiobiological investigations. Funding Support: this work is supported by funding the National Sciences and Engineering Research Council of Canada, and a Mitacs-accelerate fellowship. Conflict of Interest: Dr. Lindsay and Dr. Jaffray are listed as inventors of the small animal microirradiator described herein. This system has been licensed for commercial development.« less

  15. Measurement of charge- and mass-changing cross sections for 4He+12C collisions in the energy range 80-220 MeV/u for applications in ion beam therapy

    NASA Astrophysics Data System (ADS)

    Horst, Felix; Schuy, Christoph; Weber, Uli; Brinkmann, Kai-Thomas; Zink, Klemens

    2017-08-01

    4He ions are considered to be used for hadron radiotherapy due to their favorable physical and radiobiological properties. For an accurate dose calculation the fragmentation of the primary 4He ions occurring as a result of nuclear collisions must be taken into account. Therefore precise nuclear reaction models need to be implemented in the radiation transport codes used for dose calculation. A fragmentation experiment using thin graphite targets was conducted at the Heidelberg Ion Beam Therapy Center (HIT) to obtain new and precise 4He-nucleus cross section data in the clinically relevant energy range. Measured values for the charge-changing cross section, mass-changing cross section, as well as the inclusive 3He production cross section for 4He+12C collisions at energies between 80 and 220 MeV /u are presented. These data are compared to the 4He-nucleus reaction model by DeVries and Peng as well as to the parametrizations by Tripathi et al. and by Cucinotta et al., which are implemented in the treatment planning code trip98 and several other radiation transport codes.

  16. Nuclear model calculations and their role in space radiation research

    NASA Technical Reports Server (NTRS)

    Townsend, L. W.; Cucinotta, F. A.; Heilbronn, L. H.

    2002-01-01

    Proper assessments of spacecraft shielding requirements and concomitant estimates of risk to spacecraft crews from energetic space radiation requires accurate, quantitative methods of characterizing the compositional changes in these radiation fields as they pass through thick absorbers. These quantitative methods are also needed for characterizing accelerator beams used in space radiobiology studies. Because of the impracticality/impossibility of measuring these altered radiation fields inside critical internal body organs of biological test specimens and humans, computational methods rather than direct measurements must be used. Since composition changes in the fields arise from nuclear interaction processes (elastic, inelastic and breakup), knowledge of the appropriate cross sections and spectra must be available. Experiments alone cannot provide the necessary cross section and secondary particle (neutron and charged particle) spectral data because of the large number of nuclear species and wide range of energies involved in space radiation research. Hence, nuclear models are needed. In this paper current methods of predicting total and absorption cross sections and secondary particle (neutrons and ions) yields and spectra for space radiation protection analyses are reviewed. Model shortcomings are discussed and future needs presented. c2002 COSPAR. Published by Elsevier Science Ltd. All right reserved.

  17. New beam monitoring tool for radiobiology experiments at the cyclotron ARRONAX.

    PubMed

    Schwob, L; Koumeir, C; Servagent, N; Cherel, M; Guertin, A; Haddad, F; Métivier, V; Michel, N; Poirier, F; Rahmani, A; Varmenot, N

    2015-09-01

    The ARRONAX cyclotron is able to deliver alpha particles at 68 MeV. In the frame of radiological research, a new method is studied to infer in situ the deposited dose: it is based on the online measurement of the bremsstrahlung (>1 keV) produced by the interaction of the incident particle with the medium. Experiments are made using bombarded poly(methyl methacrylate) (PMMA)-equivalent water targets in order to characterise this continuous X-ray spectrum. The intensity of the bremsstrahlung spectrum allows for the beam monitoring. A simulation code of the bremsstrahlung has been built, and a good agreement is found with the experimental spectra. With this simulation, it is possible to predict the sensibility of this method: it varies with the target thickness, showing a good sensibility for thin target (<1000 µm) and saturation for thicker ones. Bremsstrahlung spectrum also shows a sensibility on the target's chemical composition. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. The Fate of a Normal Human Cell Traversed by a Single Charged Particle

    NASA Astrophysics Data System (ADS)

    Fournier, C.; Zahnreich, S.; Kraft, D.; Friedrich, T.; Voss, K.-O.; Durante, M.; Ritter, S.

    2012-09-01

    The long-term ``fate'' of normal human cells after single hits of charged particles is one of the oldest unsolved issues in radiation protection and cellular radiobiology. Using a high-precision heavy-ion microbeam we could target normal human fibroblasts with exactly one or five carbon ions and measured the early cytogenetic damage and the late behaviour using single-cell cloning. Around 70% of the first cycle cells presented visible aberrations in mFISH after a single ion traversal, and about 5% of the cells were still able to form colonies. In one third of selected high-proliferative colonies we observed clonal (radiation-induced) aberrations. Terminal differentiation and markers of senescence (PCNA, p16) in the descendants of cells traversed by one carbon ion occurred earlier than in controls, but no evidence of radiation-induced chromosomal instability was found. We conclude that cells surviving single-ion traversal, often carrying clonal chromosome aberrations, undergo accelerated senescence but maintain chromosomal stability.

  19. The Fate of a Normal Human Cell Traversed by a Single Charged Particle

    PubMed Central

    Fournier, C.; Zahnreich, S.; Kraft, D.; Friedrich, T.; Voss, K.-O.; Durante, M.; Ritter, S.

    2012-01-01

    The long-term “fate” of normal human cells after single hits of charged particles is one of the oldest unsolved issues in radiation protection and cellular radiobiology. Using a high-precision heavy-ion microbeam we could target normal human fibroblasts with exactly one or five carbon ions and measured the early cytogenetic damage and the late behaviour using single-cell cloning. Around 70% of the first cycle cells presented visible aberrations in mFISH after a single ion traversal, and about 5% of the cells were still able to form colonies. In one third of selected high-proliferative colonies we observed clonal (radiation-induced) aberrations. Terminal differentiation and markers of senescence (PCNA, p16) in the descendants of cells traversed by one carbon ion occurred earlier than in controls, but no evidence of radiation-induced chromosomal instability was found. We conclude that cells surviving single-ion traversal, often carrying clonal chromosome aberrations, undergo accelerated senescence but maintain chromosomal stability. PMID:22966418

  20. Electron and Ion Reactions in Molecular Solids: from astrochemistry to radiobiology

    NASA Astrophysics Data System (ADS)

    Huels, Michael A.

    2001-05-01

    Wherever ionizing radiation interacts with matter, it initiates reaction cascades involving ions, radicals, and ballistic secondary electrons; these reactions occur on fs time-scales, and may lead to substantial physical and chemical modifications of a medium. Here I present measurements of 0-80 eV electron and ion reactions in condensed films ranging from simple to complex, and astrophysical to biological in nature. Targets contain either: small molecules, hydrocarbons of increasing complexity (incl. bases, sugars, single/double stranded DNA), molecules on rare gas matrices, or mixed cryogenic films resembling astrophysical or planetary surface ices containing O2, H2O, methane, and aromatic hydrocarbons. The basic electron or ion reaction mechanisms and pathways are found to be fundamentally universal, but are modulated by the physical and chemical nature of the medium; depending on the latter, a reaction cascade may lead to different end-points, e.g. a decrease in molecular complexity via molecular fragmentations, or increases in complexity via secondary ion collision induced synthesis of larger molecules in hydrocarbon rich surface ices.

Top