DOE Office of Scientific and Technical Information (OSTI.GOV)
Barnes, G.A.
1998-03-11
This document defines the requirements applicable to the operation, maintenance and storage of the Supervisory Control and Data Acquisition System (SCADAS) and Control Network in support of the Light Duty Utility Arm (LDUA) operations.
Structural analysis of hatch cover plates on FMEF high bay mezzanine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dixson, G.E.
1997-05-29
In order to move the Idaho National Engineering Laboratory (INEL) Light Duty Utility Arm (LDUA) trailer into position for testing on the Fuels and Materials Examination Facility (FMEF) 42 ft level mezzanine one of the trailer`s wheels will have to sit on a circular hatch cover fabricated from one-inch thick steel plate. The attached calculations verify that the hatch cover plate is strong enough to support the weight of the INEL LDUA trailer`s wheel.
Design criteria for the light duty utility arm system end effectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pardini, A.F.; Kiebel, G.R.
1995-12-01
The purpose of this document is to provide criteria for the design of end effectors that will be used as part of the Light Duty Utility Arm (LDUA) System. Actual component design, fabrication, testing, and inspection will be performed by various DOE laboratories, industry, and academia. This document augments WHC-SD-TD-FRD-003, `Functions and Requirements for the Light Duty Utility Arm Integrated System` (F). All requirements dictated in the F shall also be applicable in this document. Whenever conflicts arise between this document and the F, this document shall take precedence.
Characterization engineering status report october 1998 - december 1998
DOE Office of Scientific and Technical Information (OSTI.GOV)
BOGER, R.M.
1999-05-13
Characterization Engineering (CE) continues to make progress in support of the project goal of characterizing the Hanford high-level waste tanks. Two core sampling systems were operational during this reporting period-push mode core sampling system No. 1 and rotary mode core sampling system No. 4. The availability average for core sampling systems No. 1 , No. 3 and No. 4, combined, was 45 percent, down from 79percent for the previous quarter and 58 percent for FY 1998. System No. 2 did not have scope during the quarter, and availability was not hacked. System No. 3 was out of service the entiremore » quarter for corrective maintenance. Two tanks were core sampled during the reporting period, and 24 samples were retrieved. Core sample recovery increased slightly during the quarter. System No. 1 average sample recovery increased from 80percent to 81 percent, The rotary mode core sampling average recovery increased to 62 percent from 55 percent for the previous quarter. sampling six tanks, one more than scheduled. Vapor Sampling was utilized in support of the sluicing of tank 241-C-106 and for emissions monitoring of three exhaust stacks. Increased support was provided for Vapor Sampling the Standard Hydrogen Monitoring Systems. The sampling was necessary due to freezing problems with the field-installed systems. Preparations are continuing for the Light-Duty Utility Arm (LDUA) deployment with configuration and minor hardware upgrades. The LDUA Operational Readiness Review continues. The oversight of the Nested, Fixed-Depth Sampler system development has started to increase in order to ensure that a usable system is received when the project is completed. To improve configuration control, 92 drawing sheet revisions were completed along with the generation of nine new drawing sheets. The number of outstanding Engineering Change Notices increased slightly because of the addition of more drawings into the project. continues to develop. Organizational responsibilities are being identified and documented as well as the scope and deliverables. Finishing Plant was completed, and the final reviews to authorize starting work have begun. Significant progress was made in other areas as well. Grab Sampling completed The stewardship of the Long Length Contaminated Equipment Removal equipment The engineering and work planning for opening tank 241-2361 at the Plutonium.« less
Utilization of Military Women. (A Report of Increased Utilization of Military Women, FY-1973-1977)
The purpose of the study was to examine the utilization of military women and to prepare contingency plans for increasing the use of women to offset...to the utilization of military women : History of women in the Armed Forces; potential supply of women for the Armed Forces; assignment policies...attrition rates; costs of military women versus men; and service plans for increasing use of military women .
Visual Display of 5p-arm and 3p-arm miRNA Expression with a Mobile Application.
Pan, Chao-Yu; Kuo, Wei-Ting; Chiu, Chien-Yuan; Lin, Wen-Chang
2017-01-01
MicroRNAs (miRNAs) play important roles in human cancers. In previous studies, we have demonstrated that both 5p-arm and 3p-arm of mature miRNAs could be expressed from the same precursor and we further interrogated the 5p-arm and 3p-arm miRNA expression with a comprehensive arm feature annotation list. To assist biologists to visualize the differential 5p-arm and 3p-arm miRNA expression patterns, we utilized a user-friendly mobile App to display. The Cancer Genome Atlas (TCGA) miRNA-Seq expression information. We have collected over 4,500 miRNA-Seq datasets from 15 TCGA cancer types and further processed them with the 5p-arm and 3p-arm annotation analysis pipeline. In order to be displayed with the RNA-Seq Viewer App, annotated 5p-arm and 3p-arm miRNA expression information and miRNA gene loci information were converted into SQLite tables. In this distinct application, for any given miRNA gene, 5p-arm miRNA is illustrated on the top of chromosome ideogram and 3p-arm miRNA is illustrated on the bottom of chromosome ideogram. Users can then easily interrogate the differentially 5p-arm/3p-arm expressed miRNAs with their mobile devices. This study demonstrates the feasibility and utility of RNA-Seq Viewer App in addition to mRNA-Seq data visualization.
Namasivayam, Amrita; Arcos González, Pedro; Castro Delgado, Rafael; Chi, Primus Che
2017-10-03
Maternal mortality rates can be adversely affected by armed conflict, implying a greater level of vulnerability among women, and is often linked to the lack of or limited access to maternal healthcare during conflict. Previous research in Uganda has shown that armed conflict negatively impacts women's utilization of maternal healthcare services for a multitude of reasons at the individual, health-system and political levels. This study compared aggregated Demographic and Health Surveys data from 13 districts in Northern Uganda, a conflict-affected region, with data from the rest of the country, for the use of maternal healthcare services for the years 1988, 1995, 2000, 2006 and 2011, using statistical analyses and logistic regression. Specific indicators for maternal healthcare utilization included contraceptive use, antenatal care, skilled assistance at birth and institutional delivery. Use of contraception and institutional deliveries among women in Northern Uganda was significantly lower compared to the rest of the country. However, skilled assistance at birth among women in Northern Uganda was significantly higher. The findings in this study show that armed conflict can have a negative impact on aspects of maternal healthcare such as contraceptive use and institutional deliveries; however, other indicators such as skilled assistance at birth were seen to be better among conflict-affected populations. This reiterates the complex nature of armed conflict and the interplay of different factors such as conflict intensity, existing health systems and services, and humanitarian interventions that could influence maternal healthcare utilization. Armed conflict, maternal health utilization, Northern Uganda, contraception, skilled assistance at birth, antenatal care, institutional delivery.
Carreon, Leah Y.; Anderson, Paul A.; McDonough, Christine M.; Djurasovic, Mladen; Glassman, Steven D.
2010-01-01
Study Design Cross-sectional cohort Objective This study aims to provide an algorithm estimate SF-6D utilities using data from the NDI, neck pain and arm pain scores. Summary of Background Data Although cost-utility analysis is increasingly used to provide information about the relative value of alternative interventions, health state values or utilities are rarely available from clinical trial data. The Neck Disability Index (NDI) and numeric rating scales for neck and arm pain, are widely used disease-specific measures of symptoms, function and disability in patients with cervical degenerative disorders. The purpose of this study is to provide an algorithm to allow estimation of SF-6D utilities using data from the NDI, and numeric rating scales for neck and arm pain. Methods SF-36, NDI, neck and arm pain rating scale scores were prospectively collected pre-operatively, at 12 and 24 months post-operatively in 2080 patients undergoing cervical fusion for degenerative disorders. SF-6D utilities were computed and Spearman correlation coefficients were calculated for paired observations from multiple time points between NDI, neck and arm pain scores and SF-6D utility scores. SF-6D scores were estimated from the NDI, neck and arm pain scores using a linear regression model. Using a separate, independent dataset of 396 patients in which and NDI scores were available SF-6D was estimated for each subject and compared to their actual SF-6D. Results The mean age for those in the development sample, was 50.4 ± 11.0 years and 33% were male. In the validation sample the mean age was 53.1 ± 9.9 years and 35% were male. Correlations between the SF-6D and the NDI, neck and arm pain scores were statistically significant (p<0.0001) with correlation coefficients of 0.82, 0.62, and 0.50 respectively. The regression equation using NDI alone to predict SF-6D had an R2 of 0.66 and a root mean square error (RMSE) of 0.056. In the validation analysis, there was no statistically significant difference (p=0.961) between actual mean SF-6D (0.49 ± 0.08) and the estimated mean SF-6D score (0.49 ± 0.08) using the NDI regression model. Conclusion This regression-based algorithm may be a useful tool to predict SF-6D scores in studies of cervical degenerative disease that have collected NDI but not utility scores. PMID:20847713
Health Instruction Packages: Venipuncture and Intravenous Therapy.
ERIC Educational Resources Information Center
Gray, P. Allen, Jr.; And Others
Text, illustrations, and exercises are utilized in these five learning modules to instruct nursing students in techniques for initiating intravenous (I.V.) therapy. The first module, "Selection of a Venipuncture Site: Arm" by P. Allen Gray, Jr., describes the utilization of a tourniquet in locating filled veins in the arm. The second…
Asteroid Redirect Mission Concept: A Bold Approach for Utilizing Space Resources
NASA Technical Reports Server (NTRS)
Mazanek, Daniel D.; Merrill, Raymond G.; Brophy, John R.; Mueller, Robert P.
2014-01-01
The utilization of natural resources from asteroids is an idea that is older than the Space Age. The technologies are now available to transform this endeavour from an idea into reality. The Asteroid Redirect Mission (ARM) is a mission concept which includes the goal of robotically returning a small Near-Earth Asteroid (NEA) or a multi-ton boulder from a large NEA to cislunar space in the mid 2020's using an advanced Solar Electric Propulsion (SEP) vehicle and currently available technologies. The paradigm shift enabled by the ARM concept would allow in-situ resource utilization (ISRU) to be used at the human mission departure location (i.e., cislunar space) versus exclusively at the deep-space mission destination. This approach drastically reduces the barriers associated with utilizing ISRU for human deep-space missions. The successful testing of ISRU techniques and associated equipment could enable large-scale commercial ISRU operations to become a reality and enable a future space-based economy utilizing processed asteroidal materials. This paper provides an overview of the ARM concept and discusses the mission objectives, key technologies, and capabilities associated with the mission, as well as how the ARM and associated operations would benefit humanity's quest for the exploration and settlement of space.
Schuy, Katrin; Brants, Loni M; Dors, Simone; Ströhle, Andreas; Zimmermann, Peter Lutz; Willmund, Gerd Dieter; Rau, Heinrich; Siegel, Stefan
2018-05-14
Mental illness stigma is a barrier to healthcare utilization. This study is the first to research the connection between mental illness stigma and the use of healthcare by veterans of the German Armed Forces. An overview of perceived stigma components in this sample is provided that should help understand how these factors influence healthcare utilization. 43 interviews with veterans of the German Armed Forces were conducted. The resulting data were analyzed in several coding steps. It was investigated whether the stigma experience of veterans of the German Armed Forces could be well illustrated by the theory-based stigmatization model of Link and Phelan. A set of hypotheses on stigma and healthcare utilization based on the data were developed. All stigma components according to the model of Link and Phelan were found in the sample. Internalized stigma, perceived public stigmatization, vocational disadvantage and social exclusion as well as feared misunderstanding of the military past in the civilian sector were reported as main stigma-relevant barriers to the use of healthcare. Recommendations for interventions are given to decrease mental illness stigma in this specific group of former soldiers. © Georg Thieme Verlag KG Stuttgart · New York.
Kinematically redundant arm formulations for coordinated multiple arm implementations
NASA Technical Reports Server (NTRS)
Bailey, Robert W.; Quiocho, Leslie J.; Cleghorn, Timothy F.
1990-01-01
Although control laws for kinematically redundant robotic arms were presented as early as 1969, redundant arms have only recently become recognized as viable solutions to limitations inherent to kinematically sufficient arms. The advantages of run-time control optimization and arm reconfiguration are becoming increasingly attractive as the complexity and criticality of robotic systems continues to progress. A generalized control law for a spatial arm with 7 or more degrees of freedom (DOF) based on Whitney's resolved rate formulation is given. Results from a simulation implementation utilizing this control law are presented. Furthermore, results from a two arm simulation are presented to demonstrate the coordinated control of multiple arms using this formulation.
The Importance of the Effective Utilization of Women at Arms
2015-03-01
Network Presented in Zagreb ,” South Eastern and Eastern Europe Clearinghouse for the Control of Small Arms and Light Weapons, November 5, 2010, http...for the Control of Small Arms and Light Weapons. “Report Establishing the South East Europe Women Police Officers Network Presented in Zagreb
TRAVIS AND ARMS REVISITED: A SECOND LOOK AT A WIDELY USED BIOCONCENTRATION ALGORITHM
In 1988, Travis and Arms reviewed the literature and collected data to develop a relationship between the octanolwater partition coefficient (Kow) and the uptake of organic compounds into milk and beef (Travis and Arms, 1988). These equations have been utilized for predicting bio...
Accurate positioning of long, flexible ARM's (Articulated Robotic Manipulator)
NASA Technical Reports Server (NTRS)
Malachowski, Michael J.
1988-01-01
An articulated robotic manipulator (ARM) system is being designed for space applications. Work being done on a concept utilizing an infinitely stiff laser beam for position reference is summarized. The laser beam is projected along the segments of the ARM, and the position is sensed by the beam rider modules (BRM) mounted on the distal ends of the segments. The BRM concept is the heart of the system. It utilizes a combination of lateral displacements and rotational and distance measurement sensors. These determine the relative position of the two ends of the segments with respect to each other in six degrees of freedom. The BRM measurement devices contain microprocessor controlled data acquisition and active positioning components. An indirect adaptive controller is used to accurately control the position of the ARM.
Sundaresan, Puma; Ager, Brittany; Turner, Sandra; Costa, Dan; Kneebone, Andrew; Pearse, Maria; Woo, Henry; Tesson, Stephanie; Juraskova, Ilona; Butow, Phyllis
2017-10-01
Randomised controlled trials (RCTs) are considered the 'gold-standard' for evaluating medical treatments. However, patients and clinicians report difficulties with informed consent and recruitment. We evaluated the utility of a Decision Aid (DA) in reducing RCT-related decisional conflict, and improving RCT knowledge and recruitment. Potential participants for a radiotherapy RCT were invited to participate in the current study. Participants were randomised to receive the RCT's participant information sheet with or without a DA. Questionnaires were administered at baseline, one and six months. The primary outcome measure was decisional conflict. Secondary outcome measures included knowledge regarding and recruitment to the RCT. 129 men were randomised to the DA (63) and control (66) arms. Decisional conflict was significantly lower over 6-months (p=0.048) in the DA arm. Knowledge regarding the RCT was significantly higher at 6months (p=0.033) in the DA arm. 20.6% of the DA arm (13 of 63) and 9% of the control arm (6 of 66) entered the RCT. This study demonstrates the utility of a DA in reducing decisional conflict and improving trial knowledge in men with cancer who are making decisions regarding RCT participation. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.
Soldier’s Load and the Multifunctional Utility/Logistics and Equipment-Transport
2010-06-11
Utility/Logistics Equipment-Countermine and an armed reconnaissance variant called the Armed Robotic Vehicle-Assault (Light). All three Lockheed...mission and requires various levels of human- robot interaction (National Institute of Standards and Technology 2004, 14). Teleoperation. A mode of...use of robots as an act of cowardice, especially in cultures which hold in high esteem the nobility of sacrificing oneself for a higher purpose (Singer
STS-61 crew utilizing Virtual Reality in training for HST repair mission
NASA Technical Reports Server (NTRS)
1993-01-01
Astronaut Jeffrey A. Hoffman, one of four crewmembers for STS-61 that will conduct scheduled spacewalks during the flight, wears a special helmet and gloves designed to assist in proper positioning near the telescope while on the end of the robot arm. Crewmembers are utilizing a new virtual reality training aid which assists in refining positioning patterns for Space Shuttle Endeavour's Remote Manipulator System (RMS) (36890); Astronaut Claude Nicollier looks at a computer display of the Shuttle's robot arm movements as Thomas D. Akers and Kathryn C. Thornton, mission specialists look on. Nicollier will be responsible for maneuvering the astronauts while they stand in a foot restraint on the end of the RMS arm (36891,36894); Hoffman wears a special helmet and gloves designed to assist in proper positioning near the telescope while on the end of the robot arm (35892); Nicollier looks at a computer display of the Shuttle's robot arm movements as Akers looks on (36893); While (l-r) Astron
Control strategies for a telerobot
NASA Technical Reports Server (NTRS)
Ohara, John; Stasi, Bill
1989-01-01
One of the major issues impacting the utility of telerobotic systems for space is the development of effective control strategies. For near-term applications, telerobot control is likely to utilize teleoperation methodologies with integrated supervisory control capabilities to assist the operator. Two different approaches to telerobotic control are evaluated: bilateral force reflecting master controllers and proportional rate six degrees-of-freedom hand controllers. The controllers' performance of single manipulator arm tasks is compared. Simultaneous operation of both manipulator arms and complex multiaxis slave arm movements is investigated. Task times are significantly longer and fewer errors are committed with the hand controllers. The hand controllers are also rated significantly higher in cognitive and manual control workload on the two-arm task. The master controllers are rated significantly higher in physical workload. The implications of these findings for space teleoperations and higher levels of control are discussed.
de Klerk, Susan; Buchanan, Helen; Jerosch-Herold, Christina
Systematic review. The Disabilities of the Arm Shoulder and Hand Questionnaire has multiple language versions from many countries around the world. In addition there is extensive research evidence of its psychometric properties. The purpose of this study was to systematically review the evidence available on the validity and clinical utility of the Disabilities of the Arm Shoulder and Hand as a measure of activity and participation in patients with musculoskeletal hand injuries in developing country contexts. We registered the review with international prospective register of systematic reviews prior to conducting a comprehensive literature search and extracting descriptive data. Two reviewers independently assessed methodological quality with the Consensus-Based Standards for the Selection of Health Measurement Instruments critical appraisal tool, the checklist to operationalize measurement characteristics of patient-rated outcome measures and the multidimensional model of clinical utility. Fourteen studies reporting 12 language versions met the eligibility criteria. Two language versions (Persian and Turkish) had an overall rating of good, and one (Thai) had an overall rating of excellent for cross-cultural validity. The remaining 9 language versions had an overall poor rating for cross-cultural validity. Content and construct validity and clinical utility yielded similar results. Poor quality ratings for validity and clinical utility were due to insufficient documentation of results and inadequate psychometric testing. With the increase in migration and globalization, hand therapists are likely to require a range of culturally adapted and translated versions of the Disabilities of the Arm Shoulder and Hand. Recommendations include rigorous application and reporting of cross-cultural adaptation, appropriate psychometric testing, and testing of clinical utility in routine clinical practice. Copyright © 2017 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.
Chodosh, Joshua; Colaiaco, Benjamin A; Connor, Karen Ilene; Cope, Dennis Wesley; Liu, Hangsheng; Ganz, David Avram; Richman, Mark Jason; Cherry, Debra Lynn; Blank, Joseph Moshe; Carbone, Raquel Del Pilar; Wolf, Sheldon Mark; Vickrey, Barbara Grace
2015-08-01
To compare the effectiveness and costs of telephone-only approach to in-person plus telephone for delivering an evidence-based, coordinated care management program for dementia. We randomized 151 patient-caregiver dyads from an underserved predominantly Latino community to two arms that shared a care management protocol but implemented in different formats: in-person visits at home and/or in the community plus telephone and mail, versus telephone and mail only. We compared between-arm caregiver burden and care-recipient problem behaviors (primary outcomes) and patient-caregiver dyad retention, care quality, health care utilization, and costs (secondary outcomes) at 6- and 12-months follow-up. Care quality improved substantially over time in both arms. Caregiver burden, care-recipient problem behaviors, retention, and health care utilization did not differ across arms but the in-person program cost more to deliver. Dementia care quality improved regardless of how care management was delivered; large differences in effectiveness or cost offsets were not detected. © The Author(s) 2015.
Simulation of aerodynamic noise and vibration noise in hard disk drives
NASA Astrophysics Data System (ADS)
Zhu, Lei; Shen, Sheng-Nan; Li, Hui; Zhang, Guo-Qing; Cui, Fu-Hao
2018-05-01
Internal flow field characteristics of HDDs are usually influenced by the arm swing during seek operations. This, in turn, can affect aerodynamic noise and airflow-induced noise. In this paper, the dynamic mesh method is used to calculate the flow-induced vibration (FIV) by transient structure analysis and the boundary element method (BEM) is utilized to predict the vibration noise. Two operational states are considered: the arm is fixed and swinging over the disk. Both aerodynamic noise and vibration noise inside drives increase rapidly with increase in disk rotation and arm swing velocities. The largest aerodynamic noise source is always located near the arm and swung with the arm.
Das, Ashis; Friedman, Jed; Kandpal, Eeshani; Ramana, Gandham N V; Gupta, Rudra Kumar Das; Pradhan, Madan M; Govindaraj, Ramesh
2014-12-08
Malaria continues to be a prominent global public health challenge. This study tested the effectiveness of two service delivery models for reducing the malaria burden, e.g. supportive supervision of community health workers (CHW) and community mobilization in promoting appropriate health-seeking behaviour for febrile illnesses in Odisha, India. The study population comprised 120 villages from two purposively chosen malaria-endemic districts, with 40 villages randomly assigned to each of the two treatment arms, one with both supportive supervision and community mobilization and one with community mobilization alone, as well as an observational control arm. Outcome measures included changes in the utilization of bed nets and timely care-seeking for fever from a trained provider compared to the control group. Analysis was by intention-to-treat. Significant improvements were observed in the reported utilization of bed nets in both intervention arms (84.5% in arm A and 82.4% in arm B versus 78.6% in the control arm; p < 0.001). While overall rates of treatment-seeking were equal across study arms, treatment-seeking from a CHW was higher in both intervention arms (28%; p = 0.005 and 27.6%; p = 0.007) than in the control arm (19.2%). Fever cases were significantly more likely to visit a CHW and receive a timely diagnosis of fever in the combined interventions arm than in the control arm (82.1% vs. 67.1%; p = 0.025). Care-seeking from trained providers also increased with a substitution away from untrained providers. Further, fever cases from the combined interventions arm (60.6%; p = 0.004) and the community mobilization arm (59.3%; p = 0.012) were more likely to have received treatment from a skilled provider within 24 hours than fever cases from the control arm (50.1%). In particular, women from the combined interventions arm were more likely to have received timely treatment from a skilled provider (61.6% vs. 47.2%; p = 0.028). A community-based intervention combining the supportive supervision of community health workers with intensive community mobilization and can be effective in improving care-seeking and preventive behaviour and may be used to strengthen the national malaria control programme.
32 CFR 552.102 - Requirements for possession and use.
Code of Federal Regulations, 2012 CFR
2012-07-01
... RESERVATIONS AND NATIONAL CEMETERIES REGULATIONS AFFECTING MILITARY RESERVATIONS Firearms and Weapons § 552.102... within three working days after arrival on the installation, or after obtaining the weapon, except: (1... registered firearms in unit arms rooms. The unit arms room should utilize a standard weapons card and log...
Grear, J.W. Jr.
1959-03-10
A switch adapted to maintain electrical connections under conditions of vibration or acceleration is described. According to the invention, thc switch includes a rotatable arm carrying a conductive bar arranged to close against two contacts spaced in the same plane. The firm and continuous engagement of the conductive bar with the contacts is acheived by utilizeing a spring located betwenn the vbar and athe a rem frzme and slidable mounting the bar in channel between two arms suspendef from the arm frame.
41 CFR 102-33.440 - Who must report CAS cost and utilization data?
Code of Federal Regulations, 2010 CFR
2010-07-01
...-MANAGEMENT OF GOVERNMENT AIRCRAFT Reporting Information on Government Aircraft Commercial Aviation Services... agencies, except the Armed Forces and U.S. intelligence agencies, must report CAS cost and utilization data...
Thresholds for conservation and management: structured decision making as a conceptual framework
Nichols, James D.; Eaton, Mitchell J.; Martin, Julien; Edited by Guntenspergen, Glenn R.
2014-01-01
changes in system dynamics. They are frequently incorporated into ecological models used to project system responses to management actions. Utility thresholds are components of management objectives and are values of state or performance variables at which small changes yield substantial changes in the value of the management outcome. Decision thresholds are values of system state variables at which small changes prompt changes in management actions in order to reach specified management objectives. Decision thresholds are derived from the other components of the decision process.We advocate a structured decision making (SDM) approach within which the following components are identified: objectives (possibly including utility thresholds), potential actions, models (possibly including ecological thresholds), monitoring program, and a solution algorithm (which produces decision thresholds). Adaptive resource management (ARM) is described as a special case of SDM developed for recurrent decision problems that are characterized by uncertainty. We believe that SDM, in general, and ARM, in particular, provide good approaches to conservation and management. Use of SDM and ARM also clarifies the distinct roles of ecological thresholds, utility thresholds, and decision thresholds in informed decision processes.
Bi-stable optical element actuator device
Holdener, Fred R.; Boyd, Robert D.
2002-01-01
The present invention is a bistable optical element actuator device utilizing a powered means to move an actuation arm, to which an optical element is attached, between two stable positions. A non-powered means holds the actuation arm in either of the two stable positions. The optical element may be a electromagnetic (EM) radiation or particle source, an instrument, or EM radiation or particle transmissive reflective or absorptive elements. A bearing is used to transfer motion and smoothly transition the actuation arm between the two stable positions.
STS-61 crew utilizing Virtual Reality in training for HST repair mission
1993-06-11
Astronaut Jeffrey A. Hoffman, one of four crewmembers for STS-61 that will conduct scheduled spacewalks during the flight, wears a special helmet and gloves designed to assist in proper positioning near the telescope while on the end of the robot arm. Crewmembers are utilizing a new virtual reality training aid which assists in refining positioning patterns for Space Shuttle Endeavour's Remote Manipulator System (RMS) (36890); Astronaut Claude Nicollier looks at a computer display of the Shuttle's robot arm movements as Thomas D. Akers and Kathryn C. Thornton, mission specialists look on. Nicollier will be responsible for maneuvering the astronauts while they stand in a foot restraint on the end of the RMS arm (36891,36894); Hoffman wears a special helmet and gloves designed to assist in proper positioning near the telescope while on the end of the robot arm (35892); Nicollier looks at a computer display of the Shuttle's robot arm movements as Akers looks on (36893); While (l-r) Astronauts Kenneth Bowersox, Kathryn Thornton, Richard O. Covey and Thomas D. Akers watch, Nicollier moves the Robot arm to desired locations in the Shuttle's payload bay using the Virtual Reality program (36895); Bowersox takes his turn maneuvering the RMS while mission specialist Hoffman, wearing the Virtual Reality helmet, follows his own progress on the end of the robot arm. Crewmembers participating during the training session are (l-r) Astronauts Akers, Hoffman, Bowersox, Nicollier, Covey, and Thornton. In the background, David Homan, an engineer in the JSC Engineering Directorate's Automation and Robotics Division, looks on (36896).
Sembrano, Jonathan N; Santos, Edward Rainier G; Polly, David W
2014-02-01
The O-arm (Medtronic Sofamor Danek, Inc., Memphis, TN, USA), an intraoperative CT scan imaging system, may provide high-quality imaging information to the surgeon. To our knowledge, its impact on spine surgery has not been studied. We reviewed 100 consecutive spine surgical procedures which utilized the new generation mobile intraoperative CT imaging system (O-arm). The most common diagnoses were degenerative conditions (disk disease, spondylolisthesis, stenosis and acquired kyphosis), seen in 49 patients. The most common indication for imaging was spinal instrumentation in 81 patients (74 utilized pedicle screws). In 52 (70%) of these, the O-arm was used to assess screw position after placement; in 22 (30%), it was coupled with Stealth navigation (Medtronic Sofamor Danek, Inc.) to guide screw placement. Another indication was to assess adequacy of spinal decompression in 38 patients; in 19 (50%) of these, intrathecal contrast material was used to obtain an intraoperative CT myelogram. In 20 patients O-arm findings led to direct surgeon intervention in the form of screw removal/repositioning (n=13), further decompression (n=6), interbody spacer repositioning (n=1), and removal of kyphoplasty trocar (n=1). In 20% of spine surgeries, the procedure was changed based on O-arm imaging findings. We found the O-arm to be useful for assessment of instrumentation position, adequacy of spinal decompression, and confirmation of balloon containment and cement filling in kyphoplasty. When used with navigation for image-guided surgery, it obviated the need for registration. Published by Elsevier Ltd.
C-arm positioning using virtual fluoroscopy for image-guided surgery
NASA Astrophysics Data System (ADS)
de Silva, T.; Punnoose, J.; Uneri, A.; Goerres, J.; Jacobson, M.; Ketcha, M. D.; Manbachi, A.; Vogt, S.; Kleinszig, G.; Khanna, A. J.; Wolinsky, J.-P.; Osgood, G.; Siewerdsen, J. H.
2017-03-01
Introduction: Fluoroscopically guided procedures often involve repeated acquisitions for C-arm positioning at the cost of radiation exposure and time in the operating room. A virtual fluoroscopy system is reported with the potential of reducing dose and time spent in C-arm positioning, utilizing three key advances: robust 3D-2D registration to a preoperative CT; real-time forward projection on GPU; and a motorized mobile C-arm with encoder feedback on C-arm orientation. Method: Geometric calibration of the C-arm was performed offline in two rotational directions (orbit α, orbit β). Patient registration was performed using image-based 3D-2D registration with an initially acquired radiograph of the patient. This approach for patient registration eliminated the requirement for external tracking devices inside the operating room, allowing virtual fluoroscopy using commonly available systems in fluoroscopically guided procedures within standard surgical workflow. Geometric accuracy was evaluated in terms of projection distance error (PDE) in anatomical fiducials. A pilot study was conducted to evaluate the utility of virtual fluoroscopy to aid C-arm positioning in image guided surgery, assessing potential improvements in time, dose, and agreement between the virtual and desired view. Results: The overall geometric accuracy of DRRs in comparison to the actual radiographs at various C-arm positions was PDE (mean ± std) = 1.6 ± 1.1 mm. The conventional approach required on average 8.0 ± 4.5 radiographs spent "fluoro hunting" to obtain the desired view. Positioning accuracy improved from 2.6o ± 2.3o (in α) and 4.1o ± 5.1o (in β) in the conventional approach to 1.5o ± 1.3o and 1.8o ± 1.7o, respectively, with the virtual fluoroscopy approach. Conclusion: Virtual fluoroscopy could improve accuracy of C-arm positioning and save time and radiation dose in the operating room. Such a system could be valuable to training of fluoroscopy technicians as well as intraoperative use in fluoroscopically guided procedures.
Towards a real-time interface between a biomimetic model of sensorimotor cortex and a robotic arm
Dura-Bernal, Salvador; Chadderdon, George L; Neymotin, Samuel A; Francis, Joseph T; Lytton, William W
2015-01-01
Brain-machine interfaces can greatly improve the performance of prosthetics. Utilizing biomimetic neuronal modeling in brain machine interfaces (BMI) offers the possibility of providing naturalistic motor-control algorithms for control of a robotic limb. This will allow finer control of a robot, while also giving us new tools to better understand the brain’s use of electrical signals. However, the biomimetic approach presents challenges in integrating technologies across multiple hardware and software platforms, so that the different components can communicate in real-time. We present the first steps in an ongoing effort to integrate a biomimetic spiking neuronal model of motor learning with a robotic arm. The biomimetic model (BMM) was used to drive a simple kinematic two-joint virtual arm in a motor task requiring trial-and-error convergence on a single target. We utilized the output of this model in real time to drive mirroring motion of a Barrett Technology WAM robotic arm through a user datagram protocol (UDP) interface. The robotic arm sent back information on its joint positions, which was then used by a visualization tool on the remote computer to display a realistic 3D virtual model of the moving robotic arm in real time. This work paves the way towards a full closed-loop biomimetic brain-effector system that can be incorporated in a neural decoder for prosthetic control, to be used as a platform for developing biomimetic learning algorithms for controlling real-time devices. PMID:26709323
Turan, Janet M.; Onono, Maricianah; Steinfeld, Rachel L.; Shade, Starley B.; Owuor, Kevin; Washington, Sierra; Bukusi, Elizabeth A.; Ackers, Marta L.; Kioko, Jackson; Interis, Evelyn C.; Cohen, Craig R.
2015-01-01
Background Integrating antenatal care (ANC) and HIV care may improve uptake and retention in services along the prevention of mother-to-child transmission (PMTCT) cascade. The current study aimed to determine if integration of HIV services into ANC settings improves PMTCT service utilization outcomes. Methods ANC clinics in rural Kenya were randomized to integrated (6 clinics, 569 women) or non-integrated (6 clinics, 603 women) services. Intervention clinics provided all HIV services, including highly active antiretroviral therapy (HAART), while control clinics provided PMTCT services but referred women to HIV care clinics within the same facility. PMTCT utilization outcomes among HIV-infected women (maternal HIV care enrollment, HAART initiation, and 3-month infant HIV testing uptake) were compared using generalized estimating equations and Cox regression. Results HIV care enrollment was higher in intervention compared to control clinics (69% versus 36%, Odds Ratio (OR)=3.94, 95% Confidence Interval (CI): 1.14–13.63). Median time to enrollment was significantly shorter among intervention arm women (0 versus 8 days, Hazard Ratio (HR)=2.20, 95% CI: 1.62–3.01). Eligible women in the intervention arm were more likely to initiate HAART (40% versus 17%, OR=3.22, 95% CI: 1.81–5.72). Infant testing was more common in the intervention arm (25% versus 18%), however not statistically different. No significant differences were detected in postnatal service uptake or maternal retention. Conclusions Service integration increased maternal HIV care enrollment and HAART uptake. However, PMTCT utilization outcomes were still suboptimal, and postnatal service utilization remained poor in both study arms. Further improvements in the PMTCT cascade will require additional research and interventions. PMID:25967269
Reliability of the Straight-Arm Hang for Testing Muscular Endurance among Children 2 to 5.
ERIC Educational Resources Information Center
Gabbard, Carl; And Others
1979-01-01
The straight-arm hang as a reliable testing instrument for young children is investigated with results indicating that it is a reliable indicator for four- and five-year-old children. Questionable results may occur if utilized for younger subjects and further investigation is recommended for six-to-nine-year-old subjects. (JD)
Loftus, Christopher J; Hinck, Bryan; Makovey, Iryna; Sivalingam, Sri; Monga, Manoj
2018-04-01
To determine how sheath and endoscope size affect intrarenal pelvic pressures and risk of postoperative infectious complications comparing "Mini" vs "Standard" percutaneous nephrolithotomy (PCNL). Uropathogenic Escherichia coli were grown and 10 9 of them were instilled into the porcine renal pelvis through retrograde access for 1 hour. Percutaneous access utilized a 14/16F 20 cm ureteral access sheath for the Mini arm and a 30F sheath for the Standard arm. Nephroscopy was simulated utilizing either an 8/9.8F semirigid ureteroscope or 26F nephroscope for 1 hour while intrarenal pelvic pressure was continuously monitored. Blood and tissue cultures of kidney, liver, and spleen biopsies were plated and incubated and positive cultures were confirmed with polymerase chain reaction. Intrapelvic pressures were higher in the Mini group, 18.76 ± 5.82 mm Hg vs 13.56 ± 5.82 mm Hg (p < 0.0001). Time spent above 30 mm Hg was greater in the Mini arm, 117.0 seconds vs 66.1 seconds (p = 0.0452). All pigs had positive kidney tissue cultures whereas spleen cultures were positive in 100% and 60% of pigs in the Mini and Standard arms, respectively (p = 0.0253); 90% and 30% had positive liver tissue culture in the Mini and Standard arms, respectively (p = 0.0062). Blood cultures were positive in 30% of pigs in the Mini arm compared with none in the Standard arm (p = 0.0603). Mini-PCNL was associated with higher intrarenal pressures and higher risk of end organ bacterial seeding in the setting of an infected collecting system. This suggests a higher potential for infectious complications in a clinical setting.
1990-03-01
northern African nations (excluding Egypt, which is considered a Middle East nation) which ranked among the twenty largest Third World arms importers...northern African nation [Ref. 41:p. 193]. Thus, France’s involvement in arms exports to this region was of low economic utility relative to its...policy, the British openly acknow’edge NATO as the keystone of their defense IRef. 76:p. 3]. In the alliance the United Kingdom has a role in the
Two position optical element actuator device
Holdener, Fred R.; Boyd, Robert D.
2002-01-01
The present invention is a two position optical element actuator device utilizing a powered means to hold an actuation arm, to which an optical element is attached, in a first position. A non-powered means drives the actuation arm to a second position, when the powered means ceases to receive power. The optical element may be a electromagnetic (EM) radiation or particle source, an instrument, or EM radiation or particle transmissive, reflective or absorptive elements. A bearing is used to transfer motion and smoothly transition the actuation arm from the first to second position.
Hari, Parameswaran; Lin, Huamao Mark; Zhu, Yanyan; Berg, Deborah; Richardson, Paul G; Moreau, Philippe
2018-05-29
The aim of this analysis was to assess healthcare resource utilization in the pivotal phase 3 TOURMALINE-MM1 study of the oral proteasome inhibitor ixazomib or placebo plus lenalidomide and dexamethasone (Rd) in relapsed and/or refractory multiple myeloma (RRMM). In this double-blind, placebo-controlled, randomized study (NCT01564537), 722 patients with RRMM following 1-3 prior lines of therapy received Rd plus ixazomib (ixazomib-Rd; n = 360) or matching placebo (placebo-Rd; n = 362) until disease progression or unacceptable toxicity. Healthcare resource utilization data were captured on Day 1 of each 28-day cycle, every 4 weeks during follow-up for progression-free survival, and every 12 weeks during subsequent follow-up, and included medical encounters (length of stay, inpatient, outpatient, and reason) and number of missing days from work or other activities for patients and caregivers. Exposure-adjusted rates of hospitalization were similar between the ixazomib-Rd and placebo-Rd arms, at 0.530 and 0.564 per patient year (ppy), respectively, as were outpatient visit rates (3.305 and 3.355 ppy). Mean length of hospitalization per patient was 10.0 and 10.8 days, respectively. In both arms, hospitalization and outpatient visit rates were higher in patients with two or three prior lines of treatment (ixazomib-Rd: 0.632 and 3.909 ppy; placebo-Rd: 0.774 and 3.539 ppy) compared with patients with one prior line (ixazomib-Rd: 0.460 and 2.888 ppy; placebo-Rd: 0.436 and 3.243 ppy). Patients and their caregivers who missed any work or other activity missed a median of 7 and 5 days in the ixazomib-Rd arm, respectively, vs 8 and 4 days with placebo-Rd. The study was not powered for a statistical comparison of healthcare resource utilization between treatment arms, nor did it capture costs associated with utilization of the identified healthcare resources. This pre-specified analysis demonstrated that the all-oral triplet regimen of ixazomib added to Rd did not increase healthcare resource utilization compared with placebo-Rd.
Martinez, Kathryn A.; Friese, Christopher; Kershaw, Trace; Given, Charles W.; Fendrick, A. Mark; Northouse, Laurel
2015-01-01
Purpose/Objectives To examine differences in healthcare service utilization among patients with advanced cancer participating in a nurse-led psychoeducational intervention. Design Secondary analysis of trial data. Setting Four Michigan cancer centers. Sample 484 patients with advanced cancer. Methods Patients were randomized to three groups: brief intervention, extensive intervention, or control. Medical chart review took place at baseline, three months, and six months to measure patients’ healthcare service utilization, defined as emergency department (ED) visits or inpatient hospitalizations. Multivariable logistic regression was used to examine the odds, by study arm, of visiting the ED and being hospitalized, controlling for patient sociodemographic and health status factors, as well as baseline health-related quality of life (QOL). Main Research Variables Study arm (brief, extensive, or control), ED visitation (one or more times versus none), inpatient hospitalizations (one or more times versus none), and covariates. Findings No significant differences in ED visits or inpatient hospitalizations were observed among study arms. ED visits were more frequent for patients with lung or colorectal cancer, more comorbidities, and lower baseline QOL. Baseline QOL was associated with inpatient hospitalizations in the adjusted analysis. Conclusions The psychoeducational intervention, either in brief or extensive format, is unlikely to increase healthcare service utilization. Implications for Nursing Efficacious nurse-led psychoeducational interventions to improve QOL do not place undue burdens on the healthcare system and may improve care. PMID:26148327
Repair of impact damaged utility poles with fiber reinforced polymers (FRP), phase II : [summary].
DOT National Transportation Integrated Search
2015-04-01
The aluminum and steel utility poles which support traffic signals, lighting, or mast-arm signs : are vulnerable to collisions from vehicles because of proximity to roadways. Removing these : poles for repair is costly and time-consuming, and removal...
An automatic experimental apparatus to study arm reaching in New World monkeys.
Yin, Allen; An, Jehi; Lehew, Gary; Lebedev, Mikhail A; Nicolelis, Miguel A L
2016-05-01
Several species of the New World monkeys have been used as experimental models in biomedical and neurophysiological research. However, a method for controlled arm reaching tasks has not been developed for these species. We have developed a fully automated, pneumatically driven, portable, and reconfigurable experimental apparatus for arm-reaching tasks suitable for these small primates. We have utilized the apparatus to train two owl monkeys in a visually-cued arm-reaching task. Analysis of neural recordings demonstrates directional tuning of the M1 neurons. Our apparatus allows automated control, freeing the experimenter from manual experiments. The presented apparatus provides a valuable tool for conducting neurophysiological research on New World monkeys. Copyright © 2016. Published by Elsevier B.V.
Autonomous space processor for orbital debris
NASA Technical Reports Server (NTRS)
Ramohalli, Kumar; Campbell, David; Marine, Micky; Saad, Mohamad; Bertles, Daniel; Nichols, Dave
1990-01-01
Advanced designs are being continued to develop the ultimate goal of a GETAWAY special to demonstrate economical removal of orbital debris utilizing local resources in orbit. The fundamental technical feasibility was demonstrated in 1988 through theoretical calculations, quantitative computer animation, a solar focal point cutter, a robotic arm design and a subcase model. Last year improvements were made to the solar cutter and the robotic arm. Also performed last year was a mission analysis which showed the feasibility of retrieve at least four large (greater than 1500 kg) pieces of debris. Advances made during this reporting period are the incorporation of digital control with the existing placement arm, the development of a new robotic manipulator arm, and the study of debris spin attenuation. These advances are discussed.
Zimmermann, Peter; Ströhle, Andreas; Langner, Franziska; Lanczik, Mario
2010-07-01
In 2001, women were admitted to all military careers in the German Armed Forces. This study examines whether the utilization of psychiatric services of female military personnel has changed since then. The central medical database of German military personnel for the years 2000 and 2006 was analyzed. Between 2000 and 2006, the percentage (based on the average totals of male and female military personnel) of consultations of primary care unit surgeons for psychiatric problems increased significantly for both male and female military personnel, this increase being more apparent for women than for men. Stress-related disorders showed the greatest rise. In 2006, as opposed to 2000, the total proportion of both outpatient and inpatient mental health treatment provided to female military personnel was significantly higher than for males, particularly regarding stress-related, affective and personality disorders. Gender-specific aspects should be considered more intensely in preventive and therapeutic psychiatric supply in the German Armed Forces.
A robot arm simulation with a shared memory multiprocessor machine
NASA Technical Reports Server (NTRS)
Kim, Sung-Soo; Chuang, Li-Ping
1989-01-01
A parallel processing scheme for a single chain robot arm is presented for high speed computation on a shared memory multiprocessor. A recursive formulation that is derived from a virtual work form of the d'Alembert equations of motion is utilized for robot arm dynamics. A joint drive system that consists of a motor rotor and gears is included in the arm dynamics model, in order to take into account gyroscopic effects due to the spinning of the rotor. The fine grain parallelism of mechanical and control subsystem models is exploited, based on independent computation associated with bodies, joint drive systems, and controllers. Efficiency and effectiveness of the parallel scheme are demonstrated through simulations of a telerobotic manipulator arm. Two different mechanical subsystem models, i.e., with and without gyroscopic effects, are compared, to show the trade-off between efficiency and accuracy.
Arm swing magnitude and asymmetry during gait in the early stages of Parkinson's disease.
Lewek, Michael D; Poole, Roxanne; Johnson, Julia; Halawa, Omar; Huang, Xuemei
2010-02-01
The later stages of Parkinson's disease (PD) are characterized by altered gait patterns. Although decreased arm swing during gait is the most frequently reported motor dysfunction in individuals with PD, quantitative descriptions of gait in early PD have largely ignored upper extremity movements. This study was designed to perform a quantitative analysis of arm swing magnitude and asymmetry that might be useful in the assessment of early PD. Twelve individuals with early PD (in "off" state) and eight controls underwent gait analysis using an optically-based motion capture system. Participants were instructed to walk at normal and fast velocities, and then on heels (to minimize push-off). Arm swing was measured as the excursion of the wrist with respect to the pelvis. Arm swing magnitude for each arm, and inter-arm asymmetry, were compared between groups. Both groups had comparable gait velocities (p = 0.61), and there was no significant difference between the groups in the magnitude of arm swing in all walking conditions for the arm that swung more (p = 0.907) or less (p = 0.080). Strikingly, the PD group showed significantly greater arm swing asymmetry (asymmetry angle: 13.9 + or - 7.9%) compared to the control group (asymmetry angle: 5.1 + or - 4.0%; p = 0.003). Unlike arm swing magnitude, arm swing asymmetry unequivocally differs between people with early PD and controls. Such quantitative evaluation of arm swing, especially its asymmetry, may have utility for early and differential diagnosis, and for tracking disease progression in patients with later PD. Copyright 2009 Elsevier B.V. All rights reserved.
Arm Swing Magnitude and Asymmetry During Gait in the Early Stages of Parkinson's Disease
Lewek, Michael D.; Poole, Roxanne; Johnson, Julia; Halawa, Omar; Huang, Xuemei
2009-01-01
The later stages of Parkinson's disease (PD) are characterized by altered gait patterns. Although decreased arm swing during gait is the most frequently reported motor dysfunction in individuals with PD, quantitative descriptions of gait in early PD have largely ignored upper extremity movements. This study was designed to perform a quantitative analysis of arm swing magnitude and asymmetry that might be useful in the assessment of early PD. Twelve individuals with early PD (in “off” state) and eight controls underwent gait analysis using an optically-based motion capture system. Participants were instructed to walk at normal and fast velocities, and then on heels (to minimize push-off). Arm swing was measured as the excursion of the wrist with respect to the pelvis. Arm swing magnitude for each arm, and inter-arm asymmetry, were compared between groups. Both groups had comparable gait velocities (p=0.61), and there was no significant difference between the groups in the magnitude of arm swing in all walking conditions for the arm that swung more (p=0.907) or less (p=0.080). Strikingly, the PD group showed significantly greater arm swing asymmetry (asymmetry angle: 13.9±7.9%) compared to the control group (asymmetry angle: 5.1±4.0%; p=0.003). Unlike arm swing magnitude, arm swing asymmetry unequivocally differs between people with early PD and controls. Such quantitative evaluation of arm swing, especially its asymmetry, may have utility for early and differential diagnosis, and for tracking disease progression in patients with later PD. PMID:19945285
Ostolaza, M; Abudarham, J; Dilascio, S; Drault-Boedo, E; Gallo, S; Garcete, A; Kramer, M; Maiaru, M; Mendelevich, A; Modica, M; Peralta, F; Sanchez-Correa, C
2017-04-01
In clinical practice it is important to be able to assess the function of the upper limb of the patient who has suffered a stroke. There is currently no systemic review that could identify assessment tools for the 'fine use of the hand' and 'use of both hand and arm'. Primary, to identify observational tools which can assess the fine use of the hand and the use of both hand and arm in patients with stroke sequels. Secondary, to analyze the bias risk in the included articles, describing and categorizing the clinical utility, validity and reliability. A search was carried in Medline, LILACS, SciELO and Open Grey, which included articles published until October 2015. Studies that validate assessing tools of the upper limb in subjects with a stroke sequel which evaluate the fine use of the hand and the use of both hand and arm were included. Eleven tools in evaluate observational haven been selected, which assess the fine use of the hand and the use of hand and arm. In every case both validity and reliability have been reported, but clinical utility has been less considered for assessment. The studies that researched these tools showed a high risk of bias in their development. ARAT-19 showed a lower bias risk, but when it has to do with applicability and the reference trial is taken into account, the level of concern is high.
2009-03-01
52 Figure 4-1: Applied voltage versus deflection curve for Poly1/Poly2 stacked 300-μm single hot-arm actuator (shown on right...58 Figure 4-2: Applied voltage versus deflection curve for Poly1/Poly2 stacked 300-μm double hot-arm actuator (shown on...61 Figure 4-5: Deflection vs. power curves for an individual wedge from
Principles of Jet Engine Operation
1978-05-01
and discharged from the rotor radially (perpendicular-to the axis .,f rotation). In-contrast, the axial flow compressor both admits and dis- charges... TurbofanS for most contemporary turbojet powered aircraft applications, the axial flow compressor is utilized. The remainder of the discussion will...usually installed on several radial arms which are evenly spaced around the compressor face. The spacing of the probes on the arms is such that they are
Linking Publications to Instruments, Field Campaigns, Sites and Working Groups: The ARM Experience
NASA Astrophysics Data System (ADS)
Lehnert, K.; Parsons, M. A.; Ramachandran, R.; Fils, D.; Narock, T.; Fox, P. A.; Troyan, D.; Cialella, A. T.; Gregory, L.; Lazar, K.; Liang, M.; Ma, L.; Tilp, A.; Wagener, R.
2017-12-01
For the past 25 years, the ARM Climate Research Facility - a US Department of Energy scientific user facility - has been collecting atmospheric data in different climatic regimes using both in situ and remote instrumentation. Configuration of the facility's components has been designed to improve the understanding and representation, in climate and earth system models, of clouds and aerosols. Placing a premium on long-term continuous data collection resulted in terabytes of data having been collected, stored, and made accessible to any interested person. All data is accessible via the ARM.gov website and the ARM Data Discovery Tool. A team of metadata professionals assign appropriate tags to help facilitate searching the databases for desired data. The knowledge organization tools and concepts are used to create connections between data, instruments, field campaigns, sites, and measurements are familiar to informatics professionals. Ontology, taxonomy, classification, and thesauri are among the customized concepts put into practice for ARM's purposes. In addition to the multitude of data available, there have been approximately 3,000 journal articles that utilize ARM data. These have been linked to specific ARM web pages. Searches of the complete ARM publication database can be done using a separate interface. This presentation describes how ARM data is linked to instruments, sites, field campaigns, and publications through the application of standard knowledge organization tools and concepts.
Chen, Bing; Aruin, Alexander S
2013-11-27
The magnitude of grip force used to lift and transport a hand-held object is decreased if a light finger touch from the contralateral arm is provided to the wrist of the target arm. We investigated whether the type of contralateral arm sensory input that became available with the finger touch to the target arm affects the way grip force is reduced. Nine healthy subjects performed the same task of lifting and transporting an instrumented object with no involvement of the contralateral arm and when an index finger touch of the contralateral arm was provided to the wrist, elbow, and shoulder. Touching the wrist and elbow involved movements of the contralateral arm; no movements were produced while touching the shoulder. Grip force was reduced by approximately the same amount in all conditions with the finger touch compared to the no touch condition. This suggests that information from the muscle and joint receptors of the contralateral arm is used in control of grip force when a finger touch is provided to the wrist and elbow, and cutaneous information is utilized when lifting an object while touching the shoulder. The results of the study provide additional evidence to support the use of a second arm in the performance of activities of daily living and stress the importance of future studies investigating contralateral arm sensory input in grip force control. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
A Kinematic Calibration Process for Flight Robotic Arms
NASA Technical Reports Server (NTRS)
Collins, Curtis L.; Robinson, Matthew L.
2013-01-01
The Mars Science Laboratory (MSL) robotic arm is ten times more massive than any Mars robotic arm before it, yet with similar accuracy and repeatability positioning requirements. In order to assess and validate these requirements, a higher-fidelity model and calibration processes were needed. Kinematic calibration of robotic arms is a common and necessary process to ensure good positioning performance. Most methodologies assume a rigid arm, high-accuracy data collection, and some kind of optimization of kinematic parameters. A new detailed kinematic and deflection model of the MSL robotic arm was formulated in the design phase and used to update the initial positioning and orientation accuracy and repeatability requirements. This model included a higher-fidelity link stiffness matrix representation, as well as a link level thermal expansion model. In addition, it included an actuator backlash model. Analytical results highlighted the sensitivity of the arm accuracy to its joint initialization methodology. Because of this, a new technique for initializing the arm joint encoders through hardstop calibration was developed. This involved selecting arm configurations to use in Earth-based hardstop calibration that had corresponding configurations on Mars with the same joint torque to ensure repeatability in the different gravity environment. The process used to collect calibration data for the arm included the use of multiple weight stand-in turrets with enough metrology targets to reconstruct the full six-degree-of-freedom location of the rover and tool frames. The follow-on data processing of the metrology data utilized a standard differential formulation and linear parameter optimization technique.
Manca, Andrea; Hawkins, Neil; Sculpher, Mark J
2005-05-01
In trial-based cost-effectiveness analysis baseline mean utility values are invariably imbalanced between treatment arms. A patient's baseline utility is likely to be highly correlated with their quality-adjusted life-years (QALYs) over the follow-up period, not least because it typically contributes to the QALY calculation. Therefore, imbalance in baseline utility needs to be accounted for in the estimation of mean differential QALYs, and failure to control for this imbalance can result in a misleading incremental cost-effectiveness ratio. This paper discusses the approaches that have been used in the cost-effectiveness literature to estimate absolute and differential mean QALYs alongside randomised trials, and illustrates the implications of baseline mean utility imbalance for QALY calculation. Using data from a recently conducted trial-based cost-effectiveness study and a micro-simulation exercise, the relative performance of alternative estimators is compared, showing that widely used methods to calculate differential QALYs provide incorrect results in the presence of baseline mean utility imbalance regardless of whether these differences are formally statistically significant. It is demonstrated that multiple regression methods can be usefully applied to generate appropriate estimates of differential mean QALYs and an associated measure of sampling variability, while controlling for differences in baseline mean utility between treatment arms in the trial. Copyright 2004 John Wiley & Sons, Ltd
Single-camera visual odometry to track a surgical X-ray C-arm base.
Esfandiari, Hooman; Lichti, Derek; Anglin, Carolyn
2017-12-01
This study provides a framework for a single-camera odometry system for localizing a surgical C-arm base. An application-specific monocular visual odometry system (a downward-looking consumer-grade camera rigidly attached to the C-arm base) is proposed in this research. The cumulative dead-reckoning estimation of the base is extracted based on frame-to-frame homography estimation. Optical-flow results are utilized to feed the odometry. Online positional and orientation parameters are then reported. Positional accuracy of better than 2% (of the total traveled distance) for most of the cases and 4% for all the cases studied and angular accuracy of better than 2% (of absolute cumulative changes in orientation) were achieved with this method. This study provides a robust and accurate tracking framework that not only can be integrated with the current C-arm joint-tracking system (i.e. TC-arm) but also is capable of being employed for similar applications in other fields (e.g. robotics).
Takebayashi, Takashi; Amano, Satoru; Hanada, Keisuke; Umeji, Atsushi; Takahashi, Kayoko; Koyama, Tetsuo; Domen, Kazuhisa
2014-11-01
Botulinum toxin type A (BtxA) injection, constraint-induced movement therapy (CIMT), and robotic therapy (RT) each represent promising approaches to enhance arm motor recovery after stroke. To provide more effective treatment for a 50-year-old man with severe left spastic hemiparesis, we attempted to facilitate CIMT with adaptive approaches to extend the wrist and fingers using RT for 10 consecutive weeks after BtxA injection. This combined treatment resulted in substantial improvements in arm function and the amount of arm use in activities of daily living, and may be effective for stroke patients with severe arm paresis. However, we were unable to sufficiently prove the efficacy of combined treatment based only on a single case. To fully elucidate the efficacy of the combined approach for patients with severe hemiparesis after stroke, future studies of a larger number of patients are needed. Copyright © 2014 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Speed, C; Heaven, B; Adamson, A; Bond, J; Corbett, S; Lake, A A; May, C; Vanoli, A; McMeekin, P; Moynihan, P; Rubin, G; Steen, I N; McColl, E
2010-11-01
To investigate the clinical effectiveness and cost-effectiveness of laxatives versus dietary and lifestyle advice, and standardised versus personalised dietary and lifestyle advice. A prospective, pragmatic, three-armed cluster randomised trial with an economic evaluation. General practices in England and Scotland, UK. People aged ≥ 55 years with chronic constipation, living in private households. Participants were identified as those who had been prescribed laxatives three or more times in the previous 12 months, or with a recorded diagnosis of chronic functional constipation. Prescription of laxatives, with class of laxative and dose at the discretion of the GP and patient (standard care control arm); standardised, non-personalised dietary and lifestyle advice; and, personalised dietary and lifestyle advice, with reinforcement. The primary outcome was the constipation-specific Patient Assessment of Constipation-Symptoms (PAC-SYM)/Patient Assessment of Constipation-Quality of Life (PAC-QOL). The trial planned to recruit and retain 1425 patients from 57 practices (19 per arm); however, only 154 patients were recruited from 19 practices. Due to these low recruitment rates it was not possible to report the conventional trial findings. Baseline characteristics of the sample from data gathered from both postal self-completion questionnaires and face-to-face interviews suggest that our sample experienced very few symptoms of constipation (PAC-SYM) and that the condition itself did not have a major impact upon their quality of life (PAC-QOL). The low level of symptoms of constipation is most likely explained by 90% of the sample using a laxative in the previous week. Most participants in our sample were satisfied with the performance of their laxatives, and levels of anxiety and depression were low. Their fibre consumption was classified as 'moderate' but their average water consumption fell below the recommended guidelines. Daily diaries, completed each day for a period of 6 months, were analysed primarily in terms of overall response rate and item response rates, and the participants accepted this method of data collection. For the economic evaluation, all of the trial arms experienced a reduction in utility, as measured by EQ-5D. There was no statistical evidence to suggest that either the personalised intervention arm or the standardised intervention arm was associated with significant changes in utility at 3 months compared with the control arm. Data on related health-care costs show a cost saving of £13.34 for those in the personalised arm, compared with the control arm, and a smaller cost saving for the standardised arm. These savings primarily occurred because of reduced hospital costs. There was no significant change measured in utility, so the personalised arm appeared to be the preferred course, producing the greatest cost savings. Due to the low number of participants in the trial, no firm conclusions could be drawn about the effectiveness of the interventions. However, a number of factors that contributed to the conduct and progress of the trial are highlighted, which may be relevant to others conducting research on a similar topic or population. ISRCTN73881345. This project was funded by the NIHR Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 14, No. 52. See the HTA programme website for further project information.
Ethnic and Environmental Influences on Vitamin D Requirement in Military Personnel
2006-10-01
25(OH)D, Ca2+ and PTH at baseline. We used a portable colorimeter that utilizes the CIE L*a*b* color system to measure constitutive skin color of...at baseline. We used a portable colorimeter that utilizes the CIE L*a*b* color system to measure constitutive skin tone of the upper inner arm. The
2009-01-01
Police AG Attorney-General AIC Australian intelligence community ANAO Australian National Audit Office AQMI Al-Qaida pour le Maghreb Islamique [al...Democratic Republic GIA Groupe Islamique Armé [Armed Islamic Group] xviii Considering the Creation of a Domestic Intelligence Agency in the United...health, energy, utilities, transport, manufacturing, communications, banking and finance , government services and icons, and public gatherings. 17
The STAMPEDE trial: paradigm-changing data through innovative trial design.
Carthon, Bradley C; Antonarakis, Emmanuel S
2016-09-01
Despite the numerous regulatory approvals for prostate cancer, metastatic prostate cancer remains a huge burden for men worldwide. In an exciting development, James et al . recently published data from the Systemic Therapy in Advanced or Metastatic Prostate Cancer: Evaluation of Drug Efficacy: a multi-stage multi-arm randomised control trial (STAMPEDE). This is an innovative multi-arm multi-stage (MAMS) trial that has utilized one control arm and several comparator arms in order to provide evidence for the inclusion of therapies beyond standard androgen deprivation alone. The patient population included: (I) men with high-risk, non-metastatic, node-negative disease; (II) men with distant-metastatic or node-positive disease; and (III) men with previously-treated prostate cancer by prostatectomy or definitive radiotherapy presenting with relapse. Men were to continue androgen deprivation for at least 2 years. The current data published by this group supports earlier results and provides additional evidence that docetaxel utilized in an up-front fashion provides a survival benefit in men with hormone-sensitive metastatic prostate cancer. Moreover, the initial results from STAMPEDE show how therapies without a demonstrated survival benefit can be efficiently excluded from further study once the likelihood of a benefit is ruled out by a predetermined analysis. In this piece, we will review the STAMPEDE data, contrast it with existing results, and provide our perspectives on how this will affect future trial conduct in the field of prostate cancer.
Moore, Karen A.; Zatorski, Raymond A.
2005-07-12
Systems and methods for applying a coating to an interior surface of a conduit. In one embodiment, a spray gun configured to apply a coating is attached to an extension arm which may be inserted into the bore of a pipe. The spray gun may be a thermal spray gun adapted to apply a powder coating. An evacuation system may be used to provide a volume area of reduced air pressure for drawing overspray out of the pipe interior during coating. The extension arm as well as the spray gun may be cooled to maintain a consistent temperature in the system, allowing for more consistent coating.
Methods for coating conduit interior surfaces utilizing a thermal spray gun with extension arm
Moore, Karen A.; Zatorski, Raymond A.
2007-10-02
Systems and methods for applying a coating to an interior surface of a conduit. In one embodiment, a spray gun configured to apply a coating is attached to an extension arm which may be inserted into the bore of a pipe. The spray gun may be a thermal spray gun adapted to apply a powder coating. An evacuation system may be used to provide a volume area of reduced air pressure for drawing overspray out of the pipe interior during coating. The extension arm as well as the spray gun may be cooled to maintain a consistent temperature in the system, allowing for more consistent coating.
Graf, Darin C.; Warpinski, Norman R.
1996-01-01
A system for single-phase, steady-state permeability measurements of porous rock utilizes a fluid bridge arrangement analogous to a Wheatstone bridge. The arms of the bridge contain the sample and calibrated flow resistors.
Zhou, Ming; Gao, Zhen; Chen, Fei; Xu, Haijun; Dong, Xiao; Ma, Li
2016-01-01
The inter-arm systolic blood pressure difference (SBPD) is recommended to be in relation to potential cardiovascular disease (CVD). Previous studies yielded controversial results about the association between an inter-arm SBPD ≥ 10 mmHg or ≥15 mmHg and the risk of cardiovascular mortality. Therefore, we conducted this meta-analysis to investigate this association. We searched PubMed and Embase databases through December 31, 2014, and examined the references of retrieved articles to identify relevant cohort studies. We utilized Newcastle-Ottawa scale to assess the quality of included studies and calculated the summary risk estimates in a fixed/random-effect model. All data analyses were conducted using STATA version 11.0. A total of seven studies were identified. Compared with participants with an inter-arm SBPD < 10 mmHg, the pooled hazard ratio (HR) of CVD mortality of those with an inter-arm SBPD ≥ 10 mmHg was 1.58 (95% CI: 1.3-1.93), and the pooled HR of cardiovascular mortality of participants with an inter-arm SBPD ≥ 15 mmHg versus those with an inter-arm SBPD < 15 mmHg was 1.88 (95% CI: 1.33-2.66). The findings from the present meta-analysis indicated that the detection of an inter-arm SBPD may define a subpopulation at high risk of CVD events.
RM-10A robotic manipulator system
DOE Office of Scientific and Technical Information (OSTI.GOV)
White, J.R.; Coughlan, J.B.; Harvey, H.W.
1988-01-01
The REMOTE RM-10A is a man-replacement manipulator system that has been developed specifically for use in radioactive and other hazardous environments. It can be teleoperated, with man-in-the-loop, for unstructured tasks or programmed to perform routine tasks automatically much like robots in the automated manufacturing industry. The RM-10A is a servomanipulator utilizing a closed-loop, microprocessor-based control system. The system consists of a slave assembly, master control station, and interconnecting cabling. The slave assembly is the part of the system that enters the hostile environment. It is man-like is size and configuration with two identical arms attached to a torso structure. Eachmore » arm attaches to the torso using two captive screws and two guide pins. The guide pins position and stabilize an arm during removal and reinstallation and also align the two electrical connectors located in the arm support plate and torso. These features allow easy remote replacement of an arm, and commonality of the arms allow interchangeability. The water-resistant slave assembly is equipped with gaskets and O-ring seals in the torso and arm and camera assemblies. In addition, each slave arm's elbow, wrist, and tong are protected by replaceable polyurethane boots. An upper camera assembly, consisting of a color television (TV) camera, 6:1 zoom lens, and a pan/tilt unit, mount to the torso to provide remote viewing capability.« less
Zhang, Xiaochen; Brown, Justin C; Paskett, Electra D; Zemel, Babette S; Cheville, Andrea L; Schmitz, Kathryn H
2017-07-01
Studies in breast cancer-related lymphedema (BRCL) have exclusively examined total arm volume, but not the specific tissue composition that contributes to total volume. We evaluated baseline differences in arm tissue composition [fat mass, lean mass, bone mineral content (BMC), and bone mineral density (BMD)] between the affected and unaffected arms in women with BRCL. We compared changes in arm tissue composition and self-reported lymphedema symptoms after 1 year of weight-lifting versus control. We utilized data from physical activity and lymphedema trial that included 141 women with BRCL. Arm tissue composition was quantified using dual-energy X-ray absorptiometry. The severity of lymphedema was quantified using self-report survey. Weight-lifting was performed at community fitness facilities. At baseline, the affected arm had more fat (∆ = 89.7 g; P < 0.001) and lean mass (∆ = 149.1 g; P < 0.001), but less BMC (∆ = -3.2 g; P < 0.001) and less BMD (∆ = -5.5 mg/cm 2 ; P = 0.04) than the unaffected arm. After 12 months of weight-lifting, composition of the affected arm was improved: lean mass (71.2 g; P = 0.01) and BMD (14.0 mg/cm 2 ; P = 0.02) increased, arm fat percentage decreased (-1.5%; P = 0.003). Composition of the unaffected arm was only improved in lean mass (65.2 g; P = 0·04). Increases in lean mass were associated with less severe BCRL symptoms. Among women with BRCL, slowly progressive weight-lifting could improve arm tissue composition. Changes in arm tissue composition predict changes in symptom burden. Investigating the combined effects of exercise and weight loss on arm tissue composition and BCRL symptoms may provide additional insight into the benefits of lifestyle modification on lymphedema biology.
A Bayesian pick-the-winner design in a randomized phase II clinical trial.
Chen, Dung-Tsa; Huang, Po-Yu; Lin, Hui-Yi; Chiappori, Alberto A; Gabrilovich, Dmitry I; Haura, Eric B; Antonia, Scott J; Gray, Jhanelle E
2017-10-24
Many phase II clinical trials evaluate unique experimental drugs/combinations through multi-arm design to expedite the screening process (early termination of ineffective drugs) and to identify the most effective drug (pick the winner) to warrant a phase III trial. Various statistical approaches have been developed for the pick-the-winner design but have been criticized for lack of objective comparison among the drug agents. We developed a Bayesian pick-the-winner design by integrating a Bayesian posterior probability with Simon two-stage design in a randomized two-arm clinical trial. The Bayesian posterior probability, as the rule to pick the winner, is defined as probability of the response rate in one arm higher than in the other arm. The posterior probability aims to determine the winner when both arms pass the second stage of the Simon two-stage design. When both arms are competitive (i.e., both passing the second stage), the Bayesian posterior probability performs better to correctly identify the winner compared with the Fisher exact test in the simulation study. In comparison to a standard two-arm randomized design, the Bayesian pick-the-winner design has a higher power to determine a clear winner. In application to two studies, the approach is able to perform statistical comparison of two treatment arms and provides a winner probability (Bayesian posterior probability) to statistically justify the winning arm. We developed an integrated design that utilizes Bayesian posterior probability, Simon two-stage design, and randomization into a unique setting. It gives objective comparisons between the arms to determine the winner.
Nutritional status at diagnosis in children with cancer. 2. An assessment by arm anthropometry.
Barr, Ronald; Collins, Laura; Nayiager, Trishana; Doring, Nancy; Kennedy, Charlene; Halton, Jacqueline; Walker, Scott; Sala, Alessandra; Webber, Colin
2011-04-01
Assessment of nutritional status in children with cancer is important but measures based on weight can be problematic at diagnosis, especially in those with advanced disease. Likewise, dual energy x-ray absorptiometry may be confounded by other radiological procedures and is not commonly available in low-income countries where most children with cancer live. Arm anthropometry is not subject to these constraints. In a study sample of 99 Canadian patients with cancer at diagnosis, mid-upper arm circumference correlated well with lean body mass as measured by dual energy x-ray absorptiometry but triceps skin fold thickness was a poor predictor of fat mass. Arm anthropometry can be a useful tool for the measurement of nutritional status in children with cancer. However, further studies, particularly in low-income countries and in children with solid tumors at diagnosis, are required to determine the full extent of its utility.
Comparison of forearm and upper arm blood pressures.
Singer, A J; Kahn, S R; Thode, H C; Hollander, J E
1999-01-01
In the prehospital setting it is not always feasible to obtain blood pressure (BP) readings from the upper arm. This study was performed to compare BPs obtained from subjects' forearms and upper arms in order to assess the utility of forearm BP as a surrogate for standard BP. The authors performed a prospective, cross-sectional, convenience study in a sample of ambulatory university ED patients, where each subject had sequential determinations of left upper arm and forearm BPs with an automated monitor at ED triage. The order of measurement was determined by the day of the week. Demographic and clinical data were also recorded. The main outcome measure was the correlation between upper arm and forearm systolic and diastolic BPs. Pearson's correlation coefficient and Student's t-test were used to analyze the data. 151 patients were enrolled. The mean age was 35.3+/-15.7 years; 40% were female and 78% were white. The mean forearm and upper arm systolic BPs were 129.8+/-20.7 mm Hg and 126.2+/-17.6 mm Hg (p = 0.002). The mean forearm and upper arm diastolic BPs were 80.7+/-14.5 mm Hg and 76.8+/-13.4 mm Hg (p<0.001). The correlations between forearm and upper arm systolic and diastolic BPs were 0.75 (p<0.001) and 0.72 (p<0.001). The differences between forearm and upper arm systolic and diastolic BPs were within 20 mm Hg in 86% and 94% of patients, respectively. Forearm BP is a fairly good predictor of standard upper arm BP in most patients. Forearm BP may be used when measurement of upper arm BP is not feasible.
32 CFR 508.1 - Utilization of Army bands.
Code of Federal Regulations, 2014 CFR
2014-07-01
.... (7) At official occasions and free social and entertainment activities held on or off Armed Forces installations, provided that such free social entertainment activities are conducted exclusively for the benefit...
32 CFR 508.1 - Utilization of Army bands.
Code of Federal Regulations, 2012 CFR
2012-07-01
.... (7) At official occasions and free social and entertainment activities held on or off Armed Forces installations, provided that such free social entertainment activities are conducted exclusively for the benefit...
32 CFR 508.1 - Utilization of Army bands.
Code of Federal Regulations, 2013 CFR
2013-07-01
.... (7) At official occasions and free social and entertainment activities held on or off Armed Forces installations, provided that such free social entertainment activities are conducted exclusively for the benefit...
NASA Astrophysics Data System (ADS)
Reaungamornrat, S.; Otake, Y.; Uneri, A.; Schafer, S.; Mirota, D. J.; Nithiananthan, S.; Stayman, J. W.; Khanna, A. J.; Reh, D. D.; Gallia, G. L.; Taylor, R. H.; Siewerdsen, J. H.
2012-02-01
Conventional surgical tracking configurations carry a variety of limitations in line-of-sight, geometric accuracy, and mismatch with the surgeon's perspective (for video augmentation). With increasing utilization of mobile C-arms, particularly those allowing cone-beam CT (CBCT), there is opportunity to better integrate surgical trackers at bedside to address such limitations. This paper describes a tracker configuration in which the tracker is mounted directly on the Carm. To maintain registration within a dynamic coordinate system, a reference marker visible across the full C-arm rotation is implemented, and the "Tracker-on-C" configuration is shown to provide improved target registration error (TRE) over a conventional in-room setup - (0.9+/-0.4) mm vs (1.9+/-0.7) mm, respectively. The system also can generate digitally reconstructed radiographs (DRRs) from the perspective of a tracked tool ("x-ray flashlight"), the tracker, or the C-arm ("virtual fluoroscopy"), with geometric accuracy in virtual fluoroscopy of (0.4+/-0.2) mm. Using a video-based tracker, planning data and DRRs can be superimposed on the video scene from a natural perspective over the surgical field, with geometric accuracy (0.8+/-0.3) pixels for planning data overlay and (0.6+/-0.4) pixels for DRR overlay across all C-arm angles. The field-of-view of fluoroscopy or CBCT can also be overlaid on real-time video ("Virtual Field Light") to assist C-arm positioning. The fixed transformation between the x-ray image and tracker facilitated quick, accurate intraoperative registration. The workflow and precision associated with a variety of realistic surgical tasks were significantly improved using the Tracker-on-C - for example, nearly a factor of 2 reduction in time required for C-arm positioning, reduction or elimination of dose in "hunting" for a specific fluoroscopic view, and confident placement of the x-ray FOV on the surgical target. The proposed configuration streamlines the integration of C-arm CBCT with realtime tracking and demonstrated utility in a spectrum of image-guided interventions (e.g., spine surgery) benefiting from improved accuracy, enhanced visualization, and reduced radiation exposure.
Atmospheric release model for the E-area low-level waste facility: Updates and modifications
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
The atmospheric release model (ARM) utilizes GoldSim® Monte Carlo simulation software (GTG, 2017) to evaluate the flux of gaseous radionuclides as they volatilize from E-Area disposal facility waste zones, diffuse into the air-filled soil pores surrounding the waste, and emanate at the land surface. This report documents the updates and modifications to the ARM for the next planned E-Area PA considering recommendations from the 2015 PA strategic planning team outlined by Butcher and Phifer.
Zanaboni, Paolo; Landolina, Maurizio; Marzegalli, Maurizio; Lunati, Maurizio; Perego, Giovanni B; Guenzati, Giuseppe; Curnis, Antonio; Valsecchi, Sergio; Borghetti, Francesca; Borghi, Gabriella; Masella, Cristina
2013-05-30
Heart failure patients with implantable defibrillators place a significant burden on health care systems. Remote monitoring allows assessment of device function and heart failure parameters, and may represent a safe, effective, and cost-saving method compared to conventional in-office follow-up. We hypothesized that remote device monitoring represents a cost-effective approach. This paper summarizes the economic evaluation of the Evolution of Management Strategies of Heart Failure Patients With Implantable Defibrillators (EVOLVO) study, a multicenter clinical trial aimed at measuring the benefits of remote monitoring for heart failure patients with implantable defibrillators. Two hundred patients implanted with a wireless transmission-enabled implantable defibrillator were randomized to receive either remote monitoring or the conventional method of in-person evaluations. Patients were followed for 16 months with a protocol of scheduled in-office and remote follow-ups. The economic evaluation of the intervention was conducted from the perspectives of the health care system and the patient. A cost-utility analysis was performed to measure whether the intervention was cost-effective in terms of cost per quality-adjusted life year (QALY) gained. Overall, remote monitoring did not show significant annual cost savings for the health care system (€1962.78 versus €2130.01; P=.80). There was a significant reduction of the annual cost for the patients in the remote arm in comparison to the standard arm (€291.36 versus €381.34; P=.01). Cost-utility analysis was performed for 180 patients for whom QALYs were available. The patients in the remote arm gained 0.065 QALYs more than those in the standard arm over 16 months, with a cost savings of €888.10 per patient. Results from the cost-utility analysis of the EVOLVO study show that remote monitoring is a cost-effective and dominant solution. Remote management of heart failure patients with implantable defibrillators appears to be cost-effective compared to the conventional method of in-person evaluations. ClinicalTrials.gov NCT00873899; http://clinicaltrials.gov/show/NCT00873899 (Archived by WebCite at http://www.webcitation.org/6H0BOA29f).
Tactile Robotic Topographical Mapping Without Force or Contact Sensors
NASA Technical Reports Server (NTRS)
Burke, Kevin; Melko, Joseph; Krajewski, Joel; Cady, Ian
2008-01-01
A method of topographical mapping of a local solid surface within the range of motion of a robot arm is based on detection of contact between the surface and the end effector (the fixture or tool at the tip of the robot arm). The method was conceived to enable mapping of local terrain by an exploratory robot on a remote planet, without need to incorporate delicate contact switches, force sensors, a vision system, or other additional, costly hardware. The method could also be used on Earth for determining the size and shape of an unknown surface in the vicinity of a robot, perhaps in an unanticipated situation in which other means of mapping (e.g., stereoscopic imaging or laser scanning with triangulation) are not available. The method uses control software modified to utilize the inherent capability of the robotic control system to measure the joint positions, the rates of change of the joint positions, and the electrical current demanded by the robotic arm joint actuators. The system utilizes these coordinate data and the known robot-arm kinematics to compute the position and velocity of the end effector, move the end effector along a specified trajectory, place the end effector at a specified location, and measure the electrical currents in the joint actuators. Since the joint actuator current is approximately proportional to the actuator forces and torques, a sudden rise in joint current, combined with a slowing of the joint, is a possible indication of actuator stall and surface contact. Hence, even though the robotic arm is not equipped with contact sensors, it is possible to sense contact (albeit with reduced sensitivity) as the end effector becomes stalled against a surface that one seeks to measure.
Graf, D.C.; Warpinski, N.R.
1996-08-13
A system is described for single-phase, steady-state permeability measurements of porous rock which utilizes a fluid bridge arrangement analogous to a Wheatstone bridge. The arms of the bridge contain the sample and calibrated flow resistors. 8 figs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Graf, D.C.; Warpinski, N.R.
A system is described for single-phase, steady-state permeability measurements of porous rock which utilizes a fluid bridge arrangement analogous to a Wheatstone bridge. The arms of the bridge contain the sample and calibrated flow resistors. 8 figs.
Economic evaluation of a task-shifting intervention for common mental disorders in India
Buttorff, Christine; Hock, Rebecca S; Weiss, Helen A; Naik, Smita; Araya, Ricardo; Kirkwood, Betty R; Chisholm, Daniel
2012-01-01
Abstract Objective To carry out an economic evaluation of a task-shifting intervention for the treatment of depressive and anxiety disorders in primary-care settings in Goa, India. Methods Cost–utility and cost–effectiveness analyses based on generalized linear models were performed within a trial set in 24 public and private primary-care facilities. Subjects were randomly assigned to an intervention or a control arm. Eligible subjects in the intervention arm were given psycho-education, case management, interpersonal psychotherapy and/or antidepressants by lay health workers. Subjects in the control arm were treated by physicians. The use of health-care resources, the disability of each subject and degree of psychiatric morbidity, as measured by the Revised Clinical Interview Schedule, were determined at 2, 6 and 12 months. Findings Complete data, from all three follow-ups, were collected from 1243 (75.4%) and 938 (81.7%) of the subjects enrolled in the study facilities from the public and private sectors, respectively. Within the public facilities, subjects in the intervention arm showed greater improvement in all the health outcomes investigated than those in the control arm. Time costs were also significantly lower in the intervention arm than in the control arm, whereas health system costs in the two arms were similar. Within the private facilities, however, the effectiveness and costs recorded in the two arms were similar. Conclusion Within public primary-care facilities in Goa, the use of lay health workers in the care of subjects with common mental disorders was not only cost–effective but also cost-saving. PMID:23226893
Real-time simulation of three-dimensional shoulder girdle and arm dynamics.
Chadwick, Edward K; Blana, Dimitra; Kirsch, Robert F; van den Bogert, Antonie J
2014-07-01
Electrical stimulation is a promising technology for the restoration of arm function in paralyzed individuals. Control of the paralyzed arm under electrical stimulation, however, is a challenging problem that requires advanced controllers and command interfaces for the user. A real-time model describing the complex dynamics of the arm would allow user-in-the-loop type experiments where the command interface and controller could be assessed. Real-time models of the arm previously described have not included the ability to model the independently controlled scapula and clavicle, limiting their utility for clinical applications of this nature. The goal of this study therefore was to evaluate the performance and mechanical behavior of a real-time, dynamic model of the arm and shoulder girdle. The model comprises seven segments linked by eleven degrees of freedom and actuated by 138 muscle elements. Polynomials were generated to describe the muscle lines of action to reduce computation time, and an implicit, first-order Rosenbrock formulation of the equations of motion was used to increase simulation step-size. The model simulated flexion of the arm faster than real time, simulation time being 92% of actual movement time on standard desktop hardware. Modeled maximum isometric torque values agreed well with values from the literature, showing that the model simulates the moment-generating behavior of a real human arm. The speed of the model enables experiments where the user controls the virtual arm and receives visual feedback in real time. The ability to optimize potential solutions in simulation greatly reduces the burden on the user during development.
Form of the compensatory stepping response to repeated laterally directed postural disturbances.
Hurt, Christopher P; Rosenblatt, Noah J; Grabiner, Mark D
2011-10-01
A compensatory stepping response (CSR) is a common strategy to restore dynamic stability in response to a postural disturbance. Currently, few studies have investigated the CSR to laterally directed disturbances delivered to subjects during quiet standing. The purpose of this study was to characterize the CSR of younger adults following exposure to a series of similar laterally directed disturbances for which no instructions were given with regard to the recovery response. We hypothesized that in the absence of externally applied constraints to the recovery response, subjects would be equally as likely to perform a crossover step as a sidestep sequence (SSS). We further hypothesized that there would be an asymmetry in arm abduction that would be dependent on the disturbance direction. Finally, we were interested in characterizing the effect of practice on the CSR to repeated disturbances. Ten younger adults were exposed to thirty laterally directed platform disturbances that forced a stepping response. Subjects responded by primarily utilizing a SSS that differs from previously reported results. Further, five of the ten subjects utilized a different recovery response that was dependent on the direction of the disturbance (i.e., left or right). Greater arm abduction was characterized for the arm in the direction of the external disturbance in comparison with the contralateral arm. Lastly, subjects modified their recovery response to this task within 12 disturbances. Taken together, these results suggest that recovery responses to laterally directed disturbances can be quickly modified but can be quite variable between and within subjects.
Effect of torso flexion on the lumbar torso extensor muscle sagittal plane moment arms.
Jorgensen, Michael J; Marras, William S; Gupta, Purnendu; Waters, Thomas R
2003-01-01
Accurate anatomical inputs for biomechanical models are necessary for valid estimates of internal loading. The magnitude of the moment arm of the lumbar erector muscle group is known to vary as a function of such variables as gender. Anatomical evidence indicates that the moment arms decrease during torso flexion. However, moment arm estimates in biomechanical models that account for individual variability have been derived from imaging studies from supine postures. Quantify the sagittal plane moment arms of the lumbar erector muscle group as a function of torso flexion, and identify individual characteristics that are associated with the magnitude of the moment arms as a function of torso flexion. Utilization of a 0.3 Tesla Open magnetic resonance image (MRI) to image and quantify the moment arm of the right erector muscle group as a function of gender and torso flexion. Axial MRI images through and parallel to each of the lumbar intervertebral discs at four torso flexion angles were obtained from 12 male and 12 female subjects in a lateral recumbent posture. Multivariate analysis of variance was used to investigate the differences in the moment arms at different torso flexion angles, whereas hierarchical linear regression was used to investigate associations with individual anthropometric characteristics and spinal posture. The largest decrease in the lumbar erector muscle group moment arm from neutral to 45-degree flexion occurred at the L5-S1 level (9.7% and 8.9% for men and women, respectively). Measures of spinal curvature (L1-S1 lordosis), body mass and trunk characteristics (depth or circumference) were associated with the varying moment arm at most lumbar levels. The sagittal plane moment arms of the lumbar erector muscle mass decrease as the torso flexes forward. The change in moment arms as a function of torso flexion may have an impact on prediction of spinal loading in biomechanical models.
Robotic Mirror Therapy System for Functional Recovery of Hemiplegic Arms.
Beom, Jaewon; Koh, Sukgyu; Nam, Hyung Seok; Kim, Wonshik; Kim, Yoonjae; Seo, Han Gil; Oh, Byung-Mo; Chung, Sun Gun; Kim, Sungwan
2016-08-15
Mirror therapy has been performed as effective occupational therapy in a clinical setting for functional recovery of a hemiplegic arm after stroke. It is conducted by eliciting an illusion through use of a mirror as if the hemiplegic arm is moving in real-time while moving the healthy arm. It can facilitate brain neuroplasticity through activation of the sensorimotor cortex. However, conventional mirror therapy has a critical limitation in that the hemiplegic arm is not actually moving. Thus, we developed a real-time 2-axis mirror robot system as a simple add-on module for conventional mirror therapy using a closed feedback mechanism, which enables real-time movement of the hemiplegic arm. We used 3 Attitude and Heading Reference System sensors, 2 brushless DC motors for elbow and wrist joints, and exoskeletal frames. In a feasibility study on 6 healthy subjects, robotic mirror therapy was safe and feasible. We further selected tasks useful for activities of daily living training through feedback from rehabilitation doctors. A chronic stroke patient showed improvement in the Fugl-Meyer assessment scale and elbow flexor spasticity after a 2-week application of the mirror robot system. Robotic mirror therapy may enhance proprioceptive input to the sensory cortex, which is considered to be important in neuroplasticity and functional recovery of hemiplegic arms. The mirror robot system presented herein can be easily developed and utilized effectively to advance occupational therapy.
ERIC Educational Resources Information Center
Dumont, Richard G.
This study assesses the utility of the Armed Services Vocational Aptitude Battery (A.S.V.A.B.) in predicting the academic success of students enrolled in the Automotive Service Specialist curriculum at the State University of New York Agricultural and Technical College (Alfred, New York). This document, part I of a two-part study, describes the…
Field, M.E.; Sullivan, W.H.
A precision liquid level sensor utilizes a balanced bridge, each arm including an air dielectric line. Changes in liquid level along one air dielectric line imbalance the bridge and create a voltage which is directly measurable across the bridge.
The effect of arm weight support on upper limb muscle synergies during reaching movements
2014-01-01
Background Compensating for the effect of gravity by providing arm-weight support (WS) is a technique often utilized in the rehabilitation of patients with neurological conditions such as stroke to facilitate the performance of arm movements during therapy. Although it has been shown that, in healthy subjects as well as in stroke survivors, the use of arm WS during the performance of reaching movements leads to a general reduction, as expected, in the level of activation of upper limb muscles, the effects of different levels of WS on the characteristics of the kinematics of motion and of the activity of upper limb muscles have not been thoroughly investigated before. Methods In this study, we systematically assessed the characteristics of the kinematics of motion and of the activity of 14 upper limb muscles in a group of 9 healthy subjects who performed 3-D arm reaching movements while provided with different levels of arm WS. We studied the hand trajectory and the trunk, shoulder, and elbow joint angular displacement trajectories for different levels of arm WS. Besides, we analyzed the amplitude of the surface electromyographic (EMG) data collected from upper limb muscles and investigated patterns of coordination via the analysis of muscle synergies. Results The characteristics of the kinematics of motion varied across WS conditions but did not show distinct trends with the level of arm WS. The level of activation of upper limb muscles generally decreased, as expected, with the increase in arm WS. The same eight muscle synergies were identified in all WS conditions. Their level of activation depended on the provided level of arm WS. Conclusions The analysis of muscle synergies allowed us to identify a modular organization underlying the generation of arm reaching movements that appears to be invariant to the level of arm WS. The results of this study provide a normative dataset for the assessment of the effects of the level of arm WS on muscle synergies in stroke survivors and other patients who could benefit from upper limb rehabilitation with arm WS. PMID:24594139
Human X-Linked genes regionally mapped utilizing X-autosome translocations and somatic cell hybrids.
Shows, T B; Brown, J A
1975-01-01
Human genes coding for hypoxanthine phosphoribosyltransferase (HPRT, EC 2.4.2.8; IMP:pyrophosphate phosphoribosyltransferase), glucose-6-phosphate dehydrogenase (G6PD, EC 1.1.1.49; D-glucose-6-phosphate:NADP+ 1-oxidoreductase), and phosphoglycerate kinase (PGK, EC 2.7.2.3; ATP:3-phospho-D-glycerate 1-phosphotransferase) have been assigned to specific regions on the long arm of the X chromosome by somatic cell gentic techniques. Gene assignment and linear order were determined by employing human somatic cells possessing an X/9 translocation or an X/22 translocation in man-mouse cell hybridization studies. The X/9 translocation involved the majority of the X long arm translocated to chromosome 9 and the X/22 translocation involved the distal half of the X long arm translocated to 22. In each case these rearrangements appeared to be reciprocal. Concordant segregation of X-linked enzymes and segments of the X chromosome generated by the translocations indicated assignment of the PGK gene to a proximal long arm region (q12-q22) and the HPRT and G6PD genes to the distal half (q22-qter) of the X long arm. Further evidence suggests a gene order on the X long arm of centromere-PGK-HPRT-G6PD. Images PMID:1056018
Earth orbital teleoperator manipulator system evaluation program
NASA Technical Reports Server (NTRS)
Brye, R. G.; Frederick, P. N.; Kirkpatrick, M., III; Shields, N. L., Jr.
1977-01-01
The operator's ability to perform five manipulator tip movements while using monoptic and stereoptic video systems was assessed. Test data obtained were compared with previous results to determine the impact of camera placement and stereoptic viewing on manipulator system performance. The tests were performed using the NASA MSFC extendible stiff arm Manipulator and an analog joystick controller. Two basic manipulator tasks were utilized. The minimum position change test required the operator to move the manipulator arm to touch a target contract. The dexterity test required removal and replacement of pegs.
A synchronized computational architecture for generalized bilateral control of robot arms
NASA Technical Reports Server (NTRS)
Bejczy, Antal K.; Szakaly, Zoltan
1987-01-01
This paper describes a computational architecture for an interconnected high speed distributed computing system for generalized bilateral control of robot arms. The key method of the architecture is the use of fully synchronized, interrupt driven software. Since an objective of the development is to utilize the processing resources efficiently, the synchronization is done in the hardware level to reduce system software overhead. The architecture also achieves a balaced load on the communication channel. The paper also describes some architectural relations to trading or sharing manual and automatic control.
Microelectromechanical safe arm device
Roesler, Alexander W [Tijeras, NM
2012-06-05
Microelectromechanical (MEM) apparatus and methods for operating, for preventing unintentional detonation of energetic components comprising pyrotechnic and explosive materials, such as air bag deployment systems, munitions and pyrotechnics. The MEM apparatus comprises an interrupting member that can be moved to block (interrupt) or complete (uninterrupt) an explosive train that is part of an energetic component. One or more latching members are provided that engage and prevent the movement of the interrupting member, until the one or more latching members are disengaged from the interrupting member. The MEM apparatus can be utilized as a safe and arm device (SAD) and electronic safe and arm device (ESAD) in preventing unintentional detonations. Methods for operating the MEM apparatus include independently applying drive signals to the actuators coupled to the latching members, and an actuator coupled to the interrupting member.
NASA Astrophysics Data System (ADS)
Davis, Benjamin L.; Berrier, Joel C.; Shields, Douglas W.; Kennefick, Julia; Kennefick, Daniel; Seigar, Marc S.; Lacy, Claud H. S.; Puerari, Ivânio
2012-04-01
A logarithmic spiral is a prominent feature appearing in a majority of observed galaxies. This feature has long been associated with the traditional Hubble classification scheme, but historical quotes of pitch angle of spiral galaxies have been almost exclusively qualitative. We have developed a methodology, utilizing two-dimensional fast Fourier transformations of images of spiral galaxies, in order to isolate and measure the pitch angles of their spiral arms. Our technique provides a quantitative way to measure this morphological feature. This will allow comparison of spiral galaxy pitch angle to other galactic parameters and test spiral arm genesis theories. In this work, we detail our image processing and analysis of spiral galaxy images and discuss the robustness of our analysis techniques.
Kim, Jihoon; Grillo, Janice M; Boxwala, Aziz A; Jiang, Xiaoqian; Mandelbaum, Rose B; Patel, Bhakti A; Mikels, Debra; Vinterbo, Staal A; Ohno-Machado, Lucila
2011-01-01
Our objective is to facilitate semi-automated detection of suspicious access to EHRs. Previously we have shown that a machine learning method can play a role in identifying potentially inappropriate access to EHRs. However, the problem of sampling informative instances to build a classifier still remained. We developed an integrated filtering method leveraging both anomaly detection based on symbolic clustering and signature detection, a rule-based technique. We applied the integrated filtering to 25.5 million access records in an intervention arm, and compared this with 8.6 million access records in a control arm where no filtering was applied. On the training set with cross-validation, the AUC was 0.960 in the control arm and 0.998 in the intervention arm. The difference in false negative rates on the independent test set was significant, P=1.6×10(-6). Our study suggests that utilization of integrated filtering strategies to facilitate the construction of classifiers can be helpful.
Kim, Jihoon; Grillo, Janice M; Boxwala, Aziz A; Jiang, Xiaoqian; Mandelbaum, Rose B; Patel, Bhakti A; Mikels, Debra; Vinterbo, Staal A; Ohno-Machado, Lucila
2011-01-01
Our objective is to facilitate semi-automated detection of suspicious access to EHRs. Previously we have shown that a machine learning method can play a role in identifying potentially inappropriate access to EHRs. However, the problem of sampling informative instances to build a classifier still remained. We developed an integrated filtering method leveraging both anomaly detection based on symbolic clustering and signature detection, a rule-based technique. We applied the integrated filtering to 25.5 million access records in an intervention arm, and compared this with 8.6 million access records in a control arm where no filtering was applied. On the training set with cross-validation, the AUC was 0.960 in the control arm and 0.998 in the intervention arm. The difference in false negative rates on the independent test set was significant, P=1.6×10−6. Our study suggests that utilization of integrated filtering strategies to facilitate the construction of classifiers can be helpful. PMID:22195129
Field, Michael E.; Sullivan, William H.
1985-01-01
A precision liquid level sensor utilizes a balanced R. F. bridge, each arm including an air dielectric line. Changes in liquid level along one air dielectric line imbalance the bridge and create a voltage which is directly measurable across the bridge.
Cheng, Jun; Wang, Yuming; Hou, Jinlin; Luo, Duande; Xie, Qing; Ning, Qin; Ren, Hong; Ding, Huiguo; Sheng, Jifang; Wei, Lai; Chen, Shijun; Fan, Xiaoling; Huang, Wenxiang; Pan, Chen; Gao, Zhiliang; Zhang, Jiming; Zhou, Boping; Chen, Guofeng; Wan, Mobin; Tang, Hong; Wang, Guiqiang; Yang, Yuxiu; Mohamed, Rosmawati; Guan, Richard; Lee, Tzong-Hsi; Chang, Wen-Hsiung; Zhenfei, Huang; Ye, Zhang; Xu, Daozhen
2014-12-01
In mainland China, peginterferon (PEG-IFN) alfa-2b 1.0μg/kg/wk for 24 weeks is the approved treatment for HBeAg-positive chronic hepatitis B. This multicenter, randomized trial evaluated the safety and efficacy of regimens utilizing increased dose or treatment duration in treatment-naive Chinese patients with chronic hepatitis B. 670 HBeAg-positive patients from China, Malaysia, Taiwan area, Singapore, and Thailand were enrolled. Patients received PEG-IFN alfa-2b 1.0μg/kg/wk (arm A) or 1.5μg/kg/wk (arm B) for 24 weeks, or 1.5μg/kg/wk for 48 weeks (arm C). The primary end point was loss of HBeAg 24 weeks after end of treatment. At the end of follow-up, HBeAg loss was significantly greater in arm C compared with arm A (31.3% vs. 17.3%; P=0.001) and arm B (31.3% vs. 18.1%; P=0.001). No significant difference in the rate of HBeAg loss was observed between arms A and B. The proportions of patients with HBe seroconversion, HBV DNA levels <20,000IU/mL, and ALT normalization at the end of follow-up were significantly higher in arm C compared with arm A and arm B. In arms A, B, and C, rates of early treatment discontinuation were 6.3%, 4.9%, and 8.9%; of discontinuation due to an AE, 2%, 3%, and 3%; and of AEs requiring dose modification, 3%, 6%, and 10%, respectively. In Chinese patients with HBeAg-positive chronic hepatitis B, PEG-IFN alfa-2b 1.5μg/kg/wk for 48 weeks is more efficacious compared with 1.0 and 1.5μg/kg/wk for 24 weeks. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.
Shiba, Naoto; Matsuse, Hiroo; Takano, Yoshio; Yoshimitsu, Kazuhiro; Omoto, Masayuki; Hashida, Ryuki; Tagawa, Yoshihiko; Inada, Tomohisa; Yamada, Shin; Ohshima, Hiroshi
2015-01-01
Musculoskeletal atrophy is one of the major problems of extended periods of exposure to weightlessness such as on the International Space Station (ISS). We developed the Hybrid Training System (HTS) to maintain an astronaut's musculoskeletal system using an electrically stimulated antagonist to resist the volitional contraction of the agonist instead of gravity. The present study assessed the system's orbital operation capability and utility, as well as its preventative effect on an astronaut's musculoskeletal atrophy. HTS was attached to the non-dominant arm of an astronaut staying on the ISS, and his dominant arm without HTS was established as the control (CTR). 10 sets of 10 reciprocal elbow curls were one training session, and 12 total sessions of training (3 times per week for 4 weeks) were performed. Pre and post flight ground based evaluations were performed by Biodex (muscle performance), MRI (muscle volume), and DXA (BMD, lean [muscle] mass, fat mass). Pre and post training inflight evaluations were performed by a hand held dynamometer (muscle force) and a measuring tape (upper arm circumference). The experiment was completed on schedule, and HTS functioned well without problems. Isokinetic elbow extension torque (Nm) changed -19.4% in HTS, and -21.7% in CTR. Isokinetic elbow flexion torque changed -23.7% in HTS, and there was no change in CTR. Total Work (Joule) of elbow extension changed -8.3% in HTS, and +0.3% in CTR. For elbow flexion it changed -23.3% in HTS and -32.6% in CTR. Average Power (Watts) of elbow extension changed +22.1% in HTS and -8.0% in CTR. For elbow flexion it changed -6.5% in HTS and -4.8% in CTR. Triceps muscle volume according to MRI changed +11.7% and that of biceps was +2.1% using HTS, however -0.1% and -0.4% respectively for CTR. BMD changed +4.6% in the HTS arm and -1.2% for CTR. Lean (muscle) mass of the arm changed only +10.6% in HTS. Fat mass changed -12.6% in HTS and -6.4% in CTR. These results showed the orbital operation capability and utility, and the preventive effect of HTS for an astronaut's musculoskeletal atrophy. The initial flight data together with the ground data obtained so far will be utilized in the future planning of human space exploration.
Reduced-dose C-arm computed tomography applications at a pediatric institution.
Acord, Michael; Shellikeri, Sphoorti; Vatsky, Seth; Srinivasan, Abhay; Krishnamurthy, Ganesh; Keller, Marc S; Cahill, Anne Marie
2017-12-01
Reduced-dose C-arm computed tomography (CT) uses flat-panel detectors to acquire real-time 3-D images in the interventional radiology suite to assist with anatomical localization and procedure planning. To describe dose-reduction techniques for C-arm CT at a pediatric institution and to provide guidance for implementation. We conducted a 5-year retrospective study on procedures using an institution-specific reduced-dose protocol: 5 or 8 s Dyna Rotation, 248/396 projection images/acquisition and 0.1-0.17 μGy/projection dose at the detector with 0.3/0.6/0.9-mm copper (Cu) filtration. We categorized cases by procedure type and average patient age and calculated C-arm CT and total dose area product (DAP). Two hundred twenty-two C-arm CT-guided procedures were performed with a dose-reduction protocol. The most common procedures were temporomandibular and sacroiliac joint injections (48.6%) and sclerotherapy (34.2%). C-arm CT was utilized in cases of difficult percutaneous access in less common applications such as cecostomy and gastrostomy placement, foreign body retrieval and thoracentesis. C-arm CT accounted for between 9.9% and 80.7% of the total procedural DAP. Dose-reducing techniques can preserve image quality for intervention while reducing radiation exposure to the child. This technology has multiple applications within pediatric interventional radiology and can be considered as an adjunctive imaging tool in a variety of procedures, particularly when percutaneous access is challenging despite routine fluoroscopic or ultrasound guidance.
41 CFR 102-33.430 - Who must report Federal aircraft cost and utilization data?
Code of Federal Regulations, 2010 CFR
2010-07-01
...? Executive agencies, except the Armed Forces and U.S. intelligence agencies, must report Federal cost and... aircraft only if Federal money was expended on the aircraft. Commercial Aviation Services (CAS) Cost and...
Field, M.E.; Sullivan, W.H.
1985-01-29
A precision liquid level sensor utilizes a balanced R. F. bridge, each arm including an air dielectric line. Changes in liquid level along one air dielectric line imbalance the bridge and create a voltage which is directly measurable across the bridge. 2 figs.
Landolina, Maurizio; Marzegalli, Maurizio; Lunati, Maurizio; Perego, Giovanni B; Guenzati, Giuseppe; Curnis, Antonio; Valsecchi, Sergio; Borghetti, Francesca; Borghi, Gabriella; Masella, Cristina
2013-01-01
Background Heart failure patients with implantable defibrillators place a significant burden on health care systems. Remote monitoring allows assessment of device function and heart failure parameters, and may represent a safe, effective, and cost-saving method compared to conventional in-office follow-up. Objective We hypothesized that remote device monitoring represents a cost-effective approach. This paper summarizes the economic evaluation of the Evolution of Management Strategies of Heart Failure Patients With Implantable Defibrillators (EVOLVO) study, a multicenter clinical trial aimed at measuring the benefits of remote monitoring for heart failure patients with implantable defibrillators. Methods Two hundred patients implanted with a wireless transmission–enabled implantable defibrillator were randomized to receive either remote monitoring or the conventional method of in-person evaluations. Patients were followed for 16 months with a protocol of scheduled in-office and remote follow-ups. The economic evaluation of the intervention was conducted from the perspectives of the health care system and the patient. A cost-utility analysis was performed to measure whether the intervention was cost-effective in terms of cost per quality-adjusted life year (QALY) gained. Results Overall, remote monitoring did not show significant annual cost savings for the health care system (€1962.78 versus €2130.01; P=.80). There was a significant reduction of the annual cost for the patients in the remote arm in comparison to the standard arm (€291.36 versus €381.34; P=.01). Cost-utility analysis was performed for 180 patients for whom QALYs were available. The patients in the remote arm gained 0.065 QALYs more than those in the standard arm over 16 months, with a cost savings of €888.10 per patient. Results from the cost-utility analysis of the EVOLVO study show that remote monitoring is a cost-effective and dominant solution. Conclusions Remote management of heart failure patients with implantable defibrillators appears to be cost-effective compared to the conventional method of in-person evaluations. Trial Registration ClinicalTrials.gov NCT00873899; http://clinicaltrials.gov/show/NCT00873899 (Archived by WebCite at http://www.webcitation.org/6H0BOA29f). PMID:23722666
Object recognition for autonomous robot utilizing distributed knowledge database
NASA Astrophysics Data System (ADS)
Takatori, Jiro; Suzuki, Kenji; Hartono, Pitoyo; Hashimoto, Shuji
2003-10-01
In this paper we present a novel method of object recognition utilizing a remote knowledge database for an autonomous robot. The developed robot has three robot arms with different sensors; two CCD cameras and haptic sensors. It can see, touch and move the target object from different directions. Referring to remote knowledge database of geometry and material, the robot observes and handles the objects to understand them including their physical characteristics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Myers, R.K.
This paper examines the political and technical verification issues associated with proposals to place quantitative and/or qualitative limits on the deployment of nuclear-armed sea-launched cruise missiles (SLCMs). Overviews of the arms control relationship between the United States and the Soviet Union, the development of the SLCM, and Soviet and American concepts of verification are presented. The views of the American arms control and defense communities regarding the SLCM is discussed in depth, accompanied by a detailed examination of the various methods which have been proposed to verify a SLCM limitation agreement. The conclusion is that there are no technological barriers,more » per se, to SLCM verification, but as the decision on an agreement's verifiability is a political one, the U.S. Navy should concentrate its arguments against SLCM limitations on the weapon's operational utility rather than argue that such an agreement is unverifiable.« less
An approach to simultaneous control of trajectory and interaction forces in dual-arm configurations
NASA Technical Reports Server (NTRS)
Yun, Xiaoping; Kumar, Vijay R.
1991-01-01
An approach to the control of constrained dynamic systems such as multiple arm systems, multifingered grippers, and walking vehicles is described. The basic philosophy is to utilize a minimal set of inputs to control the trajectory and the surplus input to control the constraint or interaction forces and moments in the closed chain. A dynamic control model for the closed chain is derived that is suitable for designing a controller in which the trajectory and the interaction forces and moments are explicitly controlled. Nonlinear feedback techniques derived from differential geometry are then applied to linearize and decouple the nonlinear model. These ideas are illustrated through a planar example in which two arms are used for cooperative manipulation. Results from a simulation are used to illustrate the efficacy of the method.
Kneissler, Jan; Stalph, Patrick O; Drugowitsch, Jan; Butz, Martin V
2014-01-01
It has been shown previously that the control of a robot arm can be efficiently learned using the XCSF learning classifier system, which is a nonlinear regression system based on evolutionary computation. So far, however, the predictive knowledge about how actual motor activity changes the state of the arm system has not been exploited. In this paper, we utilize the forward velocity kinematics knowledge of XCSF to alleviate the negative effect of noisy sensors for successful learning and control. We incorporate Kalman filtering for estimating successive arm positions, iteratively combining sensory readings with XCSF-based predictions of hand position changes over time. The filtered arm position is used to improve both trajectory planning and further learning of the forward velocity kinematics. We test the approach on a simulated kinematic robot arm model. The results show that the combination can improve learning and control performance significantly. However, it also shows that variance estimates of XCSF prediction may be underestimated, in which case self-delusional spiraling effects can hinder effective learning. Thus, we introduce a heuristic parameter, which can be motivated by theory, and which limits the influence of XCSF's predictions on its own further learning input. As a result, we obtain drastic improvements in noise tolerance, allowing the system to cope with more than 10 times higher noise levels.
NASA's Asteroid Redirect Mission (ARM)
NASA Astrophysics Data System (ADS)
Abell, Paul; Mazanek, Dan; Reeves, David; Naasz, Bo; Cichy, Benjamin
2015-11-01
The National Aeronautics and Space Administration (NASA) is developing a robotic mission to visit a large near-Earth asteroid (NEA), collect a multi-ton boulder from its surface, and redirect it into a stable orbit around the Moon. Once returned to cislunar space in the mid-2020s, astronauts will explore the boulder and return to Earth with samples. This Asteroid Redirect Mission (ARM) is part of NASA’s plan to advance the technologies, capabilities, and spaceflight experience needed for a human mission to the Martian system in the 2030s. Subsequent human and robotic missions to the asteroidal material would also be facilitated by its return to cislunar space. Although ARM is primarily a capability demonstration mission (i.e., technologies and associated operations), there exist significant opportunities to advance our knowledge of small bodies in the synergistic areas of science, planetary defense, asteroidal resources and in-situ resource utilization (ISRU), and capability and technology demonstrations. In order to maximize the knowledge return from the mission, NASA is organizing an ARM Investigation Team, which is being preceded by the Formulation Assessment and Support Team. These teams will be comprised of scientists, technologists, and other qualified and interested individuals to help plan the implementation and execution of ARM. An overview of robotic and crewed segments of ARM, including the mission requirements, NEA targets, and mission operations, will be provided along with a discussion of the potential opportunities associated with the mission.
The Asteroid Redirect Mission (ARM)
NASA Technical Reports Server (NTRS)
Abell, Paul
2015-01-01
The National Aeronautics and Space Administration (NASA) is developing a robotic mission to visit a large near-Earth asteroid (NEA), collect a multi-ton boulder from its surface, and redirect it into a stable orbit around the Moon. Once returned to cislunar space in the mid-2020s, astronauts will explore the boulder and return to Earth with samples. This Asteroid Redirect Mission (ARM) is part of NASA's plan to advance the technologies, capabilities, and spaceflight experience needed for a human mission to the Martian system in the 2030s. Subsequent human and robotic missions to the asteroidal material would also be facilitated by its return to cislunar space. Although ARM is primarily a capability demonstration mission (i.e., technologies and associated operations), there exist significant opportunities to advance our knowledge of small bodies in the synergistic areas of science, planetary defense, asteroidal resources and in-situ resource utilization (ISRU), and capability and technology demonstrations. In order to maximize the knowledge return from the mission, NASA is organizing an ARM Investigation Team, which is being preceded by the Formulation Assessment and Support Team. These teams will be comprised of scientists, technologists, and other qualified and interested individuals to help plan the implementation and execution of ARM. An overview of robotic and crewed segments of ARM, including the mission requirements, NEA targets, and mission operations, will be provided along with a discussion of the potential opportunities associated with the mission.
Quantifying Associations between Environmental and Social Stressors
Introduction: Association rule mining (ARM) has been widely used to identify associations between various entities in many fields. Although some studies have utilized it to analyze the relationship between chemicals and human effects, fewer have used this technique to identify an...
PEPSI, the High-Resolution Optical-IR Spectrograph for the LBT
NASA Astrophysics Data System (ADS)
Andersen, Michael; Strassmeier, Klaus; Hoffman, Axel; Woche, Manfred; Spano, Paolo
PEPSI is a high resolution fibre feed optical-IR polarimetric echelle spectrograph for the Large Binocular Telescope (LBT). PEPSI utilizes the two 8.4m LBT apertures to simultaneously record four polarization states at a resolution of 120.000. The extension of the coverage towards the IR is mainly motivated by the larger Zeeman splitting of IR lines, which would allow to study weaker/fainter magnetic structures on stars. The two optical arms, which also have an integral light mode with R up to 300.000, are under construction, while the IR arm is being designed.
Kazakidi, A; Vavourakis, V; Tsakiris, D P; Ekaterinaris, J A
2015-01-01
The fluid dynamics of cephalopods has so far received little attention in the literature, due to their complexity in structure and locomotion. The flow around octopuses, in particular, can be complicated due to their agile and dexterous arms, which frequently display some of the most diverse mechanisms of motion. The study of this flow amounts to a specific instance of the hydrodynamics problem for rough tapered cylinder geometries. The outstanding manipulative and locomotor skills of octopuses could inspire the development of advanced robotic arms, able to operate in fluid environments. Our primary aim was to study the hydrodynamic characteristics of such bio-inspired robotic models and to derive the hydrodynamic force coefficients as a concise description of the vortical flow effects. Utilizing computational fluid dynamic methods, the coefficients were computed on realistic morphologies of octopus-like arm models undergoing prescribed solid-body movements; such motions occur in nature for short durations in time, e.g. during reaching movements and exploratory behaviors. Numerical simulations were performed on translating, impulsively rotating, and maneuvering arms, around which the flow field structures were investigated. The results reveal in detail the generation of complex vortical flow structures around the moving arms. Hydrodynamic forces acting on a translating arm depend on the angle of incidence; forces generated during impulsive rotations of the arms are independent of their exact morphology and the angle of rotation; periodic motions based on a slow recovery and a fast power stroke are able to produce considerable propulsive thrust while harmonic motions are not. Parts of these results have been employed in bio-inspired models of underwater robotic mechanisms. This investigation may further assist elucidating the hydrodynamics underlying aspects of octopus locomotion and exploratory behaviors.
NASA Astrophysics Data System (ADS)
Menz, Veera Katharina; Schaffelhofer, Stefan; Scherberger, Hansjörg
2015-10-01
Objective. In the last decade, multiple brain areas have been investigated with respect to their decoding capability of continuous arm or hand movements. So far, these studies have mainly focused on motor or premotor areas like M1 and F5. However, there is accumulating evidence that anterior intraparietal area (AIP) in the parietal cortex also contains information about continuous movement. Approach. In this study, we decoded 27 degrees of freedom representing complete hand and arm kinematics during a delayed grasping task from simultaneously recorded activity in areas M1, F5, and AIP of two macaque monkeys (Macaca mulatta). Main results. We found that all three areas provided decoding performances that lay significantly above chance. In particular, M1 yielded highest decoding accuracy followed by F5 and AIP. Furthermore, we provide support for the notion that AIP does not only code categorical visual features of objects to be grasped, but also contains a substantial amount of temporal kinematic information. Significance. This fact could be utilized in future developments of neural interfaces restoring hand and arm movements.
Air Force Reading Abilities Test: Utilization Assessment.
1984-03-01
the R&DI AFHRL. TR-78.82, Predichon of Reading Grade Li.s of Seim. AApdwo from Armed Serice. Vocaionaj Ap ude Batery (ASVAB); AFHRL.TR-80-11, Reading...4. Vocabulary words that showed a likelihood of being encountered in an Air Force work environment were to be selected. Esoteric adverbs and...is not only used in the Basic Military Training environment ; it is also utilized at every Base Education Office through the OJT program. As noted
Cho, Alex H; Killeya-Jones, Ley A; O'Daniel, Julianne M; Kawamoto, Kensaku; Gallagher, Patrick; Haga, Susanne; Lucas, Joseph E; Trujillo, Gloria M; Joy, Scott V; Ginsburg, Geoffrey S
2012-01-18
Type 2 diabetes is a prevalent chronic condition globally that results in extensive morbidity, decreased quality of life, and increased health services utilization. Lifestyle changes can prevent the development of diabetes, but require patient engagement. Genetic risk testing might represent a new tool to increase patients' motivation for lifestyle changes. Here we describe the rationale, development, and design of a randomized controlled trial (RCT) assessing the clinical and personal utility of incorporating type 2 diabetes genetic risk testing into comprehensive diabetes risk assessments performed in a primary care setting. Patients are recruited in the laboratory waiting areas of two primary care clinics and enrolled into one of three study arms. Those interested in genetic risk testing are randomized to receive either a standard risk assessment (SRA) for type 2 diabetes incorporating conventional risk factors plus upfront disclosure of the results of genetic risk testing ("SRA+G" arm), or the SRA alone ("SRA" arm). Participants not interested in genetic risk testing will not receive the test, but will receive SRA (forming a third, "no-test" arm). Risk counseling is provided by clinic staff (not study staff external to the clinic). Fasting plasma glucose, insulin levels, body mass index (BMI), and waist circumference are measured at baseline and 12 months, as are patients' self-reported behavioral and emotional responses to diabetes risk information. Primary outcomes are changes in insulin resistance and BMI after 12 months; secondary outcomes include changes in diet patterns, physical activity, waist circumference, and perceived risk of developing diabetes. The utility, feasibility, and efficacy of providing patients with genetic risk information for common chronic diseases in primary care remain unknown. The study described here will help to establish whether providing type 2 diabetes genetic risk information in a primary care setting can help improve patients' clinical outcomes, risk perceptions, and/or their engagement in healthy behavior change. In addition, study design features such as the use of existing clinic personnel for risk counseling could inform the future development and implementation of care models for the use of individual genetic risk information in primary care. ClinicalTrials.gov: NCT00849563.
Hatswell, Anthony J; Thompson, Gwilym J; Maroudas, Penny A; Sofrygin, Oleg; Delea, Thomas E
2017-01-01
Ofatumumab (Arzerra ® , Novartis) is a treatment for chronic lymphocytic leukemia refractory to fludarabine and alemtuzumab [double refractory (DR-CLL)]. Ofatumumab was licensed on the basis of an uncontrolled Phase II study, Hx-CD20-406, in which patients receiving ofatumumab survived for a median of 13.9 months. However, the lack of an internal control arm presents an obstacle for the estimation of comparative effectiveness. The objective of the study was to present a method to estimate the cost effectiveness of ofatumumab in the treatment of DR-CLL. As no suitable historical control was available for modelling, the outcomes from non-responders to ofatumumab were used to model the effect of best supportive care (BSC). This was done via a Cox regression to control for differences in baseline characteristics between groups. This analysis was included in a partitioned survival model built in Microsoft ® Excel with utilities and costs taken from published sources, with costs and quality-adjusted life years (QALYs) were discounted at a rate of 3.5% per annum. Using the outcomes seen in non-responders, ofatumumab is expected to add approximately 0.62 life years (1.50 vs. 0.88). Using published utility values this translates to an additional 0.30 QALYs (0.77 vs. 0.47). At the list price, ofatumumab had a cost per QALY of £130,563, and a cost per life year of £63,542. The model was sensitive to changes in assumptions regarding overall survival estimates and utility values. This study demonstrates the potential of using data for non-responders to model outcomes for BSC in cost-effectiveness evaluations based on single-arm trials. Further research is needed on the estimation of comparative effectiveness using uncontrolled clinical studies.
Jackson, George L.; Weinberger, Morris; Kirshner, Miriam A.; Stechuchak, Karen M.; Melnyk, Stephanie D.; Bosworth, Hayden B.; Coffman, Cynthia J.; Neelon, Brian; Van Houtven, Courtney; Gentry, Pamela W.; Morris, Isis J.; Rose, Cynthia M.; Taylor, Jennifer P.; May, Carrie L.; Han, Byungjoo; Wainwright, Christi; Alkon, Aviel; Powell, Lesa; Edelman, David
2016-01-01
Despite the availability of efficacious treatments, only half of patients with hypertension achieve adequate blood pressure (BP) control. This paper describes the protocol and baseline subject characteristics of a 2-arm, 18-month randomized clinical trial of titrated disease management (TDM) for patients with pharmaceutically-treated hypertension for whom systolic blood pressure (SBP) is not controlled (≥140mmHg for non-diabetic or ≥130mmHg for diabetic patients). The trial is being conducted among patients of four clinic locations associated with a Veterans Affairs Medical Center. An intervention arm has a TDM strategy in which patients' hypertension control at baseline, 6, and 12 months determines the resource intensity of disease management. Intensity levels include: a low-intensity strategy utilizing a licensed practical nurse to provide bi-monthly, non-tailored behavioral support calls to patients whose SBP comes under control; medium-intensity strategy utilizing a registered nurse to provide monthly tailored behavioral support telephone calls plus home BP monitoring; and high-intensity strategy utilizing a pharmacist to provide monthly tailored behavioral support telephone calls, home BP monitoring, and pharmacist-directed medication management. Control arm patients receive the low-intensity strategy regardless of BP control. The primary outcome is SBP. There are 385 randomized (192 intervention; 193 control) veterans that are predominately older (mean age 63.5 years) men (92.5%). 61.8% are African American, and the mean baseline SBP for all subjects is 143.6mmHg. This trial will determine if a disease management program that is titrated by matching the intensity of resources to patients' BP control leads to superior outcomes compared to a low-intensity management strategy. PMID:27417982
Gorafi, Yasir Serag Alnor; Kim, June-Sik; Elbashir, Awad Ahmed Elawad; Tsujimoto, Hisashi
2018-04-28
The multiple synthetic derivatives platform described in this study will provide an opportunity for effective utilization of Aegilops tauschii traits and genes for wheat breeding. Introducing genes from wild relatives is the best option to increase genetic diversity and discover new alleles necessary for wheat improvement. A population harboring genomic fragments from the diploid wheat progenitor Aegilops tauschii Coss. in the background of bread wheat (Triticum aestivum L.) was developed by crossing and backcrossing 43 synthetic wheat lines with the common wheat cultivar Norin 61. We named this population multiple synthetic derivatives (MSD). To validate the suitability of this population for wheat breeding and genetic studies, we randomly selected 400 MSD lines and genotyped them by using Diversity Array Technology sequencing markers. We scored black glume as a qualitative trait and heading time in two environments in Sudan as a quantitative trait. Our results showed high genetic diversity and less recombination which is expected from the nature of the population. Genome-wide association (GWA) analysis showed one QTL at the short arm of chromosome 1D different from those alleles reported previously indicating that black glume in the MSD population is controlled by new allele at the same locus. For heading time, from the two environments, GWA analysis revealed three QTLs on the short arms of chromosomes 2A, 2B and 2D and two on the long arms of chromosomes 5A and 5D. Using the MSD population, which represents the diversity of 43 Ae. tauschii accessions representing most of its natural habitat, QTLs or genes and desired phenotypes (such as drought, heat and salinity tolerance) could be identified and selected for utilization in wheat breeding.
Jackson, George L; Weinberger, Morris; Kirshner, Miriam A; Stechuchak, Karen M; Melnyk, Stephanie D; Bosworth, Hayden B; Coffman, Cynthia J; Neelon, Brian; Van Houtven, Courtney; Gentry, Pamela W; Morris, Isis J; Rose, Cynthia M; Taylor, Jennifer P; May, Carrie L; Han, Byungjoo; Wainwright, Christi; Alkon, Aviel; Powell, Lesa; Edelman, David
2016-09-01
Despite the availability of efficacious treatments, only half of patients with hypertension achieve adequate blood pressure (BP) control. This paper describes the protocol and baseline subject characteristics of a 2-arm, 18-month randomized clinical trial of titrated disease management (TDM) for patients with pharmaceutically-treated hypertension for whom systolic blood pressure (SBP) is not controlled (≥140mmHg for non-diabetic or ≥130mmHg for diabetic patients). The trial is being conducted among patients of four clinic locations associated with a Veterans Affairs Medical Center. An intervention arm has a TDM strategy in which patients' hypertension control at baseline, 6, and 12months determines the resource intensity of disease management. Intensity levels include: a low-intensity strategy utilizing a licensed practical nurse to provide bi-monthly, non-tailored behavioral support calls to patients whose SBP comes under control; medium-intensity strategy utilizing a registered nurse to provide monthly tailored behavioral support telephone calls plus home BP monitoring; and high-intensity strategy utilizing a pharmacist to provide monthly tailored behavioral support telephone calls, home BP monitoring, and pharmacist-directed medication management. Control arm patients receive the low-intensity strategy regardless of BP control. The primary outcome is SBP. There are 385 randomized (192 intervention; 193 control) veterans that are predominately older (mean age 63.5years) men (92.5%). 61.8% are African American, and the mean baseline SBP for all subjects is 143.6mmHg. This trial will determine if a disease management program that is titrated by matching the intensity of resources to patients' BP control leads to superior outcomes compared to a low-intensity management strategy. Published by Elsevier Inc.
McClure, Jennifer B; Anderson, Melissa L
2018-02-08
Most smokers do not use evidence-based smoking cessation treatment. Increasing utilization of these services is an important public health goal. Health care systems and insurers are well positioned to support this goal within their patient populations. We tested whether a brief, mail-based intervention increased utilization of tobacco cessation services among insured smokers. Adult smokers were identified via automated health plan data and randomized to one of five treatment arms (n = 4767). Randomization was stratified by gender, age, and type of health plan coverage. Three arms received a letter containing motivational content and treatment referral information. Motivational content emphasized either the financial, health, or values-based benefits of quitting. One arm received a referral letter with no motivational content, and one arm received no letter. Enrollment in the referred tobacco cessation program was monitored for 5 months. Treatment was available to all participants through their insurance. Across all four letter conditions, 0.8% of participants enrolled in tobacco treatment compared to 0.9% in the no letter reference group (p = .69). No single letter condition was superior to the others (p = .71), but treatment uptake was greater among participants who received their care and coverage from the health plan versus those with insurance coverage only (1.2% vs. 0.3%, p < .01). A one-time, mailed letter is not a cost-effective strategy for promoting use of covered smoking cessation treatment within large health plan populations, particularly when the message source is an insurance provider only and does not also provide clinical care. Health plans and insurers should consider alternative outreach efforts to promote treatment uptake among smokers. TRN registered retrospectively with ISRCTN registry ( www.isrctn.com ). Registered on 11/01/2018. Registration number: ISRCTN32311137 .
Using virtual reality environment to facilitate training with advanced upper-limb prosthesis.
Resnik, Linda; Etter, Katherine; Klinger, Shana Lieberman; Kambe, Charles
2011-01-01
Technological advances in upper-limb prosthetic design offer dramatically increased possibilities for powered movement. The DEKA Arm system allows users 10 powered degrees of movement. Learning to control these movements by utilizing a set of motions that, in most instances, differ from those used to obtain the desired action prior to amputation is a challenge for users. In the Department of Veterans Affairs "Study to Optimize the DEKA Arm," we attempted to facilitate motor learning by using a virtual reality environment (VRE) program. This VRE program allows users to practice controlling an avatar using the controls designed to operate the DEKA Arm in the real world. In this article, we provide highlights from our experiences implementing VRE in training amputees to use the full DEKA Arm. This article discusses the use of VRE in amputee rehabilitation, describes the VRE system used with the DEKA Arm, describes VRE training, provides qualitative data from a case study of a subject, and provides recommendations for future research and implementation of VRE in amputee rehabilitation. Our experience has led us to believe that training with VRE is particularly valuable for upper-limb amputees who must master a large number of controls and for those amputees who need a structured learning environment because of cognitive deficits.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Turner, David D.; Clough, Shepard A.; Liljegren, James C.
2007-11-01
Ground-based two-channel microwave radiometers have been used for over 15 years by the Atmospheric Radiation Measurement (ARM) program to provide observations of downwelling emitted radiance from which precipitable water vapor (PWV) and liquid water path (LWP) – twp geophysical parameters critical for many areas of atmospheric research – are retrieved. An algorithm that utilizes two advanced retrieval techniques, a computationally expensive physical-iterative approach and an efficient statistical method, has been developed to retrieve these parameters. An important component of this Microwave Retrieval (MWRRET) algorithm is the determination of small (< 1K) offsets that are subtracted from the observed brightness temperaturesmore » before the retrievals are performed. Accounting for these offsets removes systematic biases from the observations and/or the model spectroscopy necessary for the retrieval, significantly reducing the systematic biases in the retrieved LWP. The MWRRET algorithm provides significantly more accurate retrievals than the original ARM statistical retrieval which uses monthly retrieval coefficients. By combining the two retrieval methods with the application of brightness temperature offsets to reduce the spurious LWP bias in clear skies, the MWRRET algorithm provides significantly better retrievals of PWV and LWP from the ARM 2-channel microwave radiometers compared to the original ARM product.« less
[Management of war orthopaedic injuries in recent armed conflicts].
Frank, M; Mathieu, L
2013-01-01
The extremities continue to be the most frequent sites of wounding during armed conflicts despite the change of combat tactics, soldier armour and battlefield medical support. Due to the advances in prehospital care and timely transport to the hospital, orthopaedic surgeons deal with severe and challenging injuries of the limbs. In contrast to civilian extremity trauma, the most combat-related injuries are open wounds that often have infection-related complications. Data from two recent large armed conflicts (Iraq, Afghanistan) show that extremity injuries are associated with a high complication rate, morbidity and healthcare utilization. A systematic approach that consists of sequential surgical care and good transport capabilities can reduce the complication rate of these injuries. New medical technologies have been implemented in the treatment strategy during the last decade. This article reviews the published scientific data and current opinions on combat-related extremity injuries. Key words: extremity, combat, trauma, medical support system.
NASA Astrophysics Data System (ADS)
Davis, Benjamin L.; Berrier, J. C.; Shields, D. W.; Kennefick, J.; Kennefick, D.; Seigar, M. S.; Lacy, C. H. S.; Puerari, I.
2012-01-01
A logarithmic spiral is a prominent feature appearing in a majority of observed galaxies. This feature has long been associated with the traditional Hubble classification scheme, but historical quotes of pitch angle of spiral galaxies have been almost exclusively qualitative. We have developed a methodology, utilizing Two-Dimensional Fast Fourier Transformations of images of spiral galaxies, in order to isolate and measure the pitch angles of their spiral arms. Our technique provides a quantitative way to measure this morphological feature. This will allow the precise comparison of spiral galaxy evolution to other galactic parameters and test spiral arm genesis theories. In this work, we detail our image processing and analysis of spiral galaxy images and discuss the robustness of our analysis techniques. The authors gratefully acknowledge support for this work from NASA Grant NNX08AW03A.
An Overview of NASA's Asteroid Redirect Mission (ARM) Concept
NASA Technical Reports Server (NTRS)
Abell, P. A.; Mazanek, D. D.; Reeves, D. M.; Chodas, P. W.; Gates, M. M.; Johnson, L. N.; Ticker, R. L.
2016-01-01
The National Aeronautics and Space Administration (NASA) is developing the Asteroid Redirect Mission (ARM) as a capability demonstration for future human exploration, including use of high-power solar electric propulsion, which allows for the efficient movement of large masses through deep space. The ARM will also demonstrate the capability to conduct proximity operations with natural space objects and crewed operations beyond the security of quick Earth return. The Asteroid Redirect Robotic Mission (ARRM), currently in formulation, will visit a large near-Earth asteroid (NEA), collect a multi-ton boulder from its surface, conduct a demonstration of a slow push planetary defense technique, and redirect the multi-ton boulder into a stable orbit around the Moon. Once returned to cislunar space in the mid-2020s, astronauts aboard an Orion spacecraft will dock with the robotic vehicle to explore the boulder and return samples to Earth. The ARM is part of NASA's plan to advance technologies, capabilities, and spaceflight experience needed for a human mission to the Martian system in the 2030s. The ARM and subsequent availability of the asteroidal material in cis-lunar space, provide significant opportunities to advance our knowledge of small bodies in the synergistic areas of science, planetary defense, and in-situ resource utilization (ISRU). NASA established the Formulation Assessment and Support Team (FAST), comprised of scientists, engineers, and technologists, which supported ARRM mission requirements formulation, answered specific questions concerning potential target asteroid physical properties, and produced a publically available report. The ARM Investigation Team is being organized to support ARM implementation and execution. NASA is also open to collaboration with its international partners and welcomes further discussions. An overview of the ARM robotic and crewed segments, including mission requirements, NEA targets, and mission operations, and a discussion of potential opportunities for participation with the ARM will be provided.
ENGINEERING MANPOWER BULLETIN NUMBER 9.
ERIC Educational Resources Information Center
ALDEN, JOHN D.
DESIGNED TO INFORM LEADERS IN INDUSTRY, GOVERNMENT, AND EDUCATION, WHOSE RESPONSIBILITY INCLUDES AWARENESS OF ENGINEERING MANPOWER DEVELOPMENTS, THIS BULLETIN REPORTS A STUDY CONDUCTED BY THE ENGINEERING MANPOWER COMMISSION OF ENGINEERS IN THE ARMED SERVICES. THE WORK OF THE COMMISSION IS TO ASSURE THE MOST EFFECTIVE UTILIZATION OF ENGINEERING…
Fatigue Transfer in Endurance Performance
ERIC Educational Resources Information Center
Caplan, Calvin S.
1976-01-01
This study investigated the question as to whether or not fatigue produced by performance of heavy physical work involving the legs would transfer to and impair following performance that utilized the muscles of the arms; under certain exercises and conditions transfer was found to take place. (JD)
Circular tomosynthesis for neuro perfusion imaging on an interventional C-arm
NASA Astrophysics Data System (ADS)
Claus, Bernhard E.; Langan, David A.; Al Assad, Omar; Wang, Xin
2015-03-01
There is a clinical need to improve cerebral perfusion assessment during the treatment of ischemic stroke in the interventional suite. The clinician is able to determine whether the arterial blockage was successfully opened but is unable to sufficiently assess blood flow through the parenchyma. C-arm spin acquisitions can image the cerebral blood volume (CBV) but are challenged to capture the temporal dynamics of the iodinated contrast bolus, which is required to derive, e.g., cerebral blood flow (CBF) and mean transit time (MTT). Here we propose to utilize a circular tomosynthesis acquisition on the C-arm to achieve the necessary temporal sampling of the volume at the cost of incomplete data. We address the incomplete data problem by using tools from compressed sensing and incorporate temporal interpolation to improve our temporal resolution. A CT neuro perfusion data set is utilized for generating a dynamic (4D) volumetric model from which simulated tomo projections are generated. The 4D model is also used as a ground truth reference for performance evaluation. The performance that may be achieved with the tomo acquisition and 4D reconstruction (under simulation conditions, i.e., without considering data fidelity limitations due to imaging physics and imaging chain) is evaluated. In the considered scenario, good agreement between the ground truth and the tomo reconstruction in the parenchyma was achieved.
Strength tests for elite rowers: low- or high-repetition?
Lawton, Trent W; Cronin, John B; McGuigan, Michael R
2014-01-01
The purpose of this project was to evaluate the utility of low- and high-repetition maximum (RM) strength tests used to assess rowers. Twenty elite heavyweight males (age 23.7 ± 4.0 years) performed four tests (5 RM, 30 RM, 60 RM and 120 RM) using leg press and seated arm pulling exercise on a dynamometer. Each test was repeated on two further occasions; 3 and 7 days from the initial trial. Per cent typical error (within-participant variation) and intraclass correlation coefficients (ICCs) were calculated using log-transformed repeated-measures data. High-repetition tests (30 RM, 60 RM and 120 RM), involving seated arm pulling exercise are not recommended to be included in an assessment battery, as they had unsatisfactory measurement precision (per cent typical error > 5% or ICC < 0.9). Conversely, low-repetition tests (5 RM) involving leg press and seated arm pulling exercises could be used to assess elite rowers (per cent typical error ≤ 5% and ICC ≥ 0.9); however, only 5 RM leg pressing met criteria (per cent typical error = 2.7%, ICC = 0.98) for research involving small samples (n = 20). In summary, low-repetition 5 RM strength testing offers greater utility as assessments of rowers, as they can be used to measure upper- and lower-body strength; however, only the leg press exercise is recommended for research involving small squads of elite rowers.
Takano, Yoshio; Yoshimitsu, Kazuhiro; Omoto, Masayuki; Hashida, Ryuki; Tagawa, Yoshihiko; Inada, Tomohisa; Yamada, Shin; Ohshima, Hiroshi
2015-01-01
Background Musculoskeletal atrophy is one of the major problems of extended periods of exposure to weightlessness such as on the International Space Station (ISS). We developed the Hybrid Training System (HTS) to maintain an astronaut’s musculoskeletal system using an electrically stimulated antagonist to resist the volitional contraction of the agonist instead of gravity. The present study assessed the system’s orbital operation capability and utility, as well as its preventative effect on an astronaut’s musculoskeletal atrophy. Methods HTS was attached to the non-dominant arm of an astronaut staying on the ISS, and his dominant arm without HTS was established as the control (CTR). 10 sets of 10 reciprocal elbow curls were one training session, and 12 total sessions of training (3 times per week for 4 weeks) were performed. Pre and post flight ground based evaluations were performed by Biodex (muscle performance), MRI (muscle volume), and DXA (BMD, lean [muscle] mass, fat mass). Pre and post training inflight evaluations were performed by a hand held dynamometer (muscle force) and a measuring tape (upper arm circumference). Results The experiment was completed on schedule, and HTS functioned well without problems. Isokinetic elbow extension torque (Nm) changed -19.4% in HTS, and -21.7% in CTR. Isokinetic elbow flexion torque changed -23.7% in HTS, and there was no change in CTR. Total Work (Joule) of elbow extension changed -8.3% in HTS, and +0.3% in CTR. For elbow flexion it changed -23.3% in HTS and -32.6% in CTR. Average Power (Watts) of elbow extension changed +22.1% in HTS and -8.0% in CTR. For elbow flexion it changed -6.5% in HTS and -4.8% in CTR. Triceps muscle volume according to MRI changed +11.7% and that of biceps was +2.1% using HTS, however -0.1% and -0.4% respectively for CTR. BMD changed +4.6% in the HTS arm and -1.2% for CTR. Lean (muscle) mass of the arm changed only +10.6% in HTS. Fat mass changed -12.6% in HTS and -6.4% in CTR. Conclusions These results showed the orbital operation capability and utility, and the preventive effect of HTS for an astronaut’s musculoskeletal atrophy. The initial flight data together with the ground data obtained so far will be utilized in the future planning of human space exploration. PMID:26296204
ERIC Educational Resources Information Center
Peterson, Norman G., Ed.
As part of the United States Army's Project A, research has been conducted to develop and field test a battery of experimental tests to complement the Armed Services Vocational Aptitude Battery in predicting soldiers' job performance. Project A is the United States Army's large-scale manpower effort to improve selection, classification, and…
Identification and classification of upper limb motions using PCA.
Veer, Karan; Vig, Renu
2018-03-28
This paper describes the utility of principal component analysis (PCA) in classifying upper limb signals. PCA is a powerful tool for analyzing data of high dimension. Here, two different input strategies were explored. The first method uses upper arm dual-position-based myoelectric signal acquisition and the other solely uses PCA for classifying surface electromyogram (SEMG) signals. SEMG data from the biceps and the triceps brachii muscles and four independent muscle activities of the upper arm were measured in seven subjects (total dataset=56). The datasets used for the analysis are rotated by class-specific principal component matrices to decorrelate the measured data prior to feature extraction.
Postural stability of sitting women.
Nag, Pranab K; Vyas, Heer; Nag, Anjali; Pal, Swati
2013-01-01
The study examined the utility of stabilometric dimensions and explored whether the changes in sitting postures were manifested in functional measures of postural control. Eleven women participated in the study, which used 11 chair sitting postures: arms on laps or arms right angled; armrest at a height of 17, 20 and 23 cm; with or without backrest; slouch or straight back; legs right angled at knees or crossed legs. The backrest and armrest shifted 16.3% of body weight from a seat pan. The characteristics of stabilometric dimensions evaluated the influence of seat components and sitting behaviour on postural balance. The study attempted to evaluate stability and its application in human-seat interface design.
Baldys, Stanley
2009-01-01
The U.S. Geological Survey, in cooperation with the City of Dallas Water Utilities Division, collected water-quality data from 11 sites on Lake Texoma, a reservoir on the Texas-Oklahoma border, during April 2007-September 2008. At 10 of the sites, physical properties (depth, specific conductance, pH, temperature, dissolved oxygen, and alkalinity) were measured and samples were collected for analysis of selected dissolved constituents (bromide, calcium, magnesium, potassium, sodium, carbonate, bicarbonate, chloride, and sulfate); at one site, only physical properties were measured. The primary constituent of interest was bromide. Bromate can form when ozone is used to disinfect raw water containing bromide, and bromate is a suspected human carcinogen. Chloride and sulfate were of secondary interest. Only the analytical results for bromide, chloride, sulfate, and measured specific conductance are discussed in this report. Median dissolved bromide concentrations ranged from 0.28 to 0.60 milligrams per liter. The largest median dissolved bromide concentration (0.60 milligram per liter at site 11) was from the Red River arm of Lake Texoma. Dissolved bromide concentrations generally were larger in the Red River arm of Lake Texoma than in the Washita arm of the lake. Median dissolved chloride concentrations were largest in the Red River arm of Lake Texoma at site 11 (431 milligrams per liter) and smallest at site 8 (122 milligrams per liter) in the Washita arm. At site 11 in the Red River arm, the mean and median chloride concentrations exceeded the secondary maximum contaminant level of 300 milligrams per liter for chloride established by the 'Texas Surface Water Quality Standards' for surface-water bodies designated for the public water supply use. Median dissolved sulfate concentrations ranged from 182 milligrams per liter at site 4 in the Big Mineral arm to 246 milligrams per liter at site 11 in the Red River arm. None of the mean or median sulfate concentrations exceeded the secondary maximum contaminant level of 300 milligrams per liter. Median specific conductance measurements at sites ranged from 1,120 microsiemens per centimeter at site 8 in the Washita arm to 2,100 microsiemens per centimeter in the Red River arm. The spatial distribution of specific conductance in Lake Texoma was similar to that of bromide and chloride, with larger specific conductance values in the Red River arm compared to those in the Washita arm.
Impact of direct substitution of arm span length for current standing height in elderly COPD.
Pothirat, Chaicharn; Chaiwong, Warawut; Phetsuk, Nittaya
2015-01-01
Arm span length is related to standing height and has been studied as a substitute for current standing height for predicting lung function parameters. However, it has never been studied in elderly COPD patients. To evaluate the accuracy of substituting arm span length for current standing height in the evaluation of pulmonary function parameters and severity classification in elderly Thai COPD patients. Current standing height and arm span length were measured in COPD patients aged >60 years. Postbronchodilator spirometric parameters, forced vital capacity (FVC), forced expiratory volume in first second (FEV1), and ratio of FEV1/FVC (FEV1%), were used to classify disease severity according to global initiative for chronic obstructive lung disease criteria. Predicted values for each parameter were also calculated separately utilizing current standing height or arm span length measurements. Student's t-tests and chi-squared tests were used to compare differences between the groups. Statistical significance was set at P<0.05. A total of 106 COPD patients with a mean age of 72.1±7.8 years, mean body mass index of 20.6±3.8 kg/m(2), and mean standing height of 156.4±8.3 cm were enrolled. The mean arm span length exceeded mean standing height by 7.7±4.6 cm (164.0±9.0 vs 156.4±8.3 cm, P<0.001), at a ratio of 1.05±0.03. Percentages of both predicted FVC and FEV1 values based on arm span length were significantly lower than those using current standing height (76.6±25.4 vs 61.6±16.8, P<0.001 and 50.8±25.4 vs 41.1±15.3, P<0.001). Disease severity increased in 39.6% (42/106) of subjects using arm span length over current standing height for predicted lung function. Direct substitution of arm span length for current standing height in elderly Thai COPD patients should not be recommended in cases where arm span length exceeds standing height by more than 4 cm.
Randomized controlled trial of a dose consolidation program.
Delate, Thomas; Fairman, Kathleen A; Carey, Shelly M; Motheral, Brenda R
2004-01-01
To evaluate the effectiveness and financial impact of a drug dose consolidation (optimization) program using letter intervention. This pilot program in a large, mid-Atlantic health plan utilized a randomized controlled trial research design. A review of adjudicated pharmacy claims records was performed monthly for 3 consecutive months from November 2002 through February 2003 to identify inefficient (i.e., >once-daily) regimens for any one of 68 dosage strengths of 37 single-source maintenance drugs with once-daily dosing recommendations. Prescribers who had prescribed one or more inefficient regimens were identified and randomized to one of the 2 intervention arms or a control arm. Prescribers in both intervention arms were sent personalized letters with information on their patients. inefficient regimens and suggested dose consolidation options. Patients of prescribers in one intervention arm received a complementary, patient-oriented letter. Pharmacy claims for patients in all arms were examined at 180 days after the date of the letter mailing for conversion to an efficient (once-daily) regimen. Financial modeling analysis calculated net savings as changes in pharmacy expenditures minus administrative costs. A total of 2,614 inefficient regimens, representing 6.7% of claims for the targeted medications, were identified. The rate of consolidation to a suggested dosing option was lower for the Physician Letter arm (7.3%) than for the Physician/Member Letter arm (10.2%) (P = 0.046). Both intervention arms had higher consolidation rates than the Control arm (3.9%) (P = 0.018 and P = 0.000, respectively.). Approximately 30% of the regimens in each study arm were never refilled after being targeted. Financial modeling indicated that a dose consolidation intervention could save 0.03 dollars to 0.07 dollars per member per month (PMPM) in 2003 dollars with full medication compliance but only 0.02 dollars to 0.03 dollars PMPM when savings were calculated with realistic, partial compliance rates. Subanalyses performed at the drug therapy class level revealed few opportunities to justify implementing a dose consolidation program. After taking into consideration program administrative costs, high rates of refill discontinuation, and dose consolidation that occurs naturally without intervention, the results indicated that a letter-based dose consolidation program did not appreciably decrease pharmacy expenditures.
Forman, Michele R; Zhu, Yeyi; Hernandez, Ladia M; Himes, John H; Dong, Yongquan; Danish, Robert K; James, Kyla E; Caulfield, Laura E; Kerver, Jean M; Arab, Lenore; Voss, Paula; Hale, Daniel E; Kanafani, Nadim; Hirschfeld, Steven
2014-09-01
Surrogate measures are needed when recumbent length or height is unobtainable or unreliable. Arm span has been used as a surrogate but is not feasible in children with shoulder or arm contractures. Ulnar length is not usually impaired by joint deformities, yet its utility as a surrogate has not been adequately studied. In this cross-sectional study, we aimed to examine the accuracy and reliability of ulnar length measured by different tools as a surrogate measure of recumbent length and height. Anthropometrics [recumbent length, height, arm span, and ulnar length by caliper (ULC), ruler (ULR), and grid (ULG)] were measured in 1479 healthy infants and children aged <6 y across 8 study centers in the United States. Multivariate mixed-effects linear regression models for recumbent length and height were developed by using ulnar length and arm span as surrogate measures. The agreement between the measured length or height and the predicted values by ULC, ULR, ULG, and arm span were examined by Bland-Altman plots. All 3 measures of ulnar length and arm span were highly correlated with length and height. The degree of precision of prediction equations for length by ULC, ULR, and ULG (R(2) = 0.95, 0.95, and 0.92, respectively) was comparable with that by arm span (R(2) = 0.97) using age, sex, and ethnicity as covariates; however, height prediction by ULC (R(2) = 0.87), ULR (R(2) = 0.85), and ULG (R(2) = 0.88) was less comparable with arm span (R(2) = 0.94). Our study demonstrates that arm span and ULC, ULR, or ULG can serve as accurate and reliable surrogate measures of recumbent length and height in healthy children; however, ULC, ULR, and ULG tend to slightly overestimate length and height in young infants and children. Further testing of ulnar length as a surrogate is warranted in physically impaired or nonambulatory children. © 2014 American Society for Nutrition.
Rausch, Franziska; Mier, Daniela; Eifler, Sarah; Fenske, Sabrina; Schirmbeck, Frederike; Englisch, Susanne; Schilling, Claudia; Meyer-Lindenberg, Andreas; Kirsch, Peter; Zink, Mathias
2015-01-01
Background Patients with schizophrenia display metacognitive impairments, such as hasty decision-making during probabilistic reasoning — the “jumping to conclusion” bias (JTC). Our recent fMRI study revealed reduced activations in the right ventral striatum (VS) and the ventral tegmental area (VTA) to be associated with decision-making in patients with schizophrenia. It is unclear whether these functional alterations occur in the at-risk mental state (ARMS). Methods We administered the classical beads task and fMRI among ARMS patients and healthy controls matched for age, sex, education and premorbid verbal intelligence. None of the ARMS patients was treated with antipsychotics. Both tasks request probabilistic decisions after a variable amount of stimuli. We evaluated activation during decision-making under certainty versus uncertainty and the process of final decision-making. Results We included 24 AMRS patients and 24 controls in our study. Compared with controls, ARMS patients tended to draw fewer beads and showed significantly more JTC bias in the classical beads task, mirroring findings in patients with schizophrenia. During fMRI, ARMS patients did not demonstrate JTC bias on the behavioural level, but showed a significant hypoactivation in the right VS during the decision stage. Limitations Owing to the cross-sectional design of the study, results are constrained to a better insight into the neurobiology of risk constellations, but not pre-psychotic stages. Nine of the ARMS patients were treated with antidepressants and/or lorazepam. Conclusion As in patients with schizophrenia, a striatal hypoactivation was found in ARMS patients. Confounding effects of antipsychotic medication can be excluded. Our findings indicate that error prediction signalling and reward anticipation may be linked to striatal dysfunction during prodromal stages and should be examined for their utility in predicting transition risk. PMID:25622039
Use of the DEKA Arm for amputees with brachial plexus injury: A case series.
Resnik, Linda; Fantini, Christopher; Latlief, Gail; Phillips, Samuel; Sasson, Nicole; Sepulveda, Eve
2017-01-01
Patients with upper limb amputation and brachial plexus injuries have high rates of prosthesis rejection. Study purpose is to describe experiences of subjects with transhumeral amputation and brachial plexus injury, who were fit with, and trained to use, a DEKA Arm. This was a mixed-methods study utilizing qualitative (e.g. interview, survey) and quantitative data (e.g. self-report and performance measures). Subject 1, a current prosthesis user, had a shoulder arthrodesis. Subject 2, not a prosthesis user, had a subluxed shoulder. Both were trained in laboratory and participated in a trial of home use. Descriptive analyses of processes and outcomes were conducted. Subject 1 was fitted with the transhumeral configuration (HC) DEKA Arm using a compression release stabilized socket. He had 12 hours of prosthetic training and participated in all home study activities. Subject 1 had improved dexterity and prosthetic satisfaction with the DEKA Arm and reported better quality of life (QOL) at the end of participation. Subject 2 was fit with the shoulder configuration (SC) DEKA Arm using a modified X-frame socket. He had 30 hours of training and participated in 3 weeks of home activities. He reported less functional disability at the end of training as compared to baseline, but encountered personal problems and exacerbation of PTSD symptoms and withdrew from home use portion at 3 weeks. Both subjects reported functional benefits from use, and expressed a desire to receive a DEKA Arm in the future. This paper reported on two different strategies for prosthetic fitting and their outcomes. The advantages and limitations of each approach were discussed. Use of both the HC and SC DEKA Arm for patients with TH amputation and brachial plexus injury was reported. Lessons learned may be instructive to clinicians considering prosthetic choices for future cases.
Rausch, Franziska; Mier, Daniela; Eifler, Sarah; Fenske, Sabrina; Schirmbeck, Frederike; Englisch, Susanne; Schilling, Claudia; Meyer-Lindenberg, Andreas; Kirsch, Peter; Zink, Mathias
2015-05-01
Patients with schizophrenia display metacognitive impairments, such as hasty decision-making during probabilistic reasoning - the "jumping to conclusion" bias (JTC). Our recent fMRI study revealed reduced activations in the right ventral striatum (VS) and the ventral tegmental area (VTA) to be associated with decision-making in patients with schizophrenia. It is unclear whether these functional alterations occur in the at-risk mental state (ARMS). We administered the classical beads task and fMRI among ARMS patients and healthy controls matched for age, sex, education and premorbid verbal intelligence. None of the ARMS patients was treated with antipsychotics. Both tasks request probabilistic decisions after a variable amount of stimuli. We evaluated activation during decision-making under certainty versus uncertainty and the process of final decision-making. We included 24 AMRS patients and 24 controls in our study. Compared with controls, ARMS patients tended to draw fewer beads and showed significantly more JTC bias in the classical beads task, mirroring findings in patients with schizophrenia. During fMRI, ARMS patients did not demonstrate JTC bias on the behavioural level, but showed a significant hypoactivation in the right VS during the decision stage. Owing to the cross-sectional design of the study, results are constrained to a better insight into the neurobiology of risk constellations, but not prepsychotic stages. Nine of the ARMS patients were treated with antidepressants and/or lorazepam. As in patients with schizophrenia, a striatal hypoactivation was found in ARMS patients. Confounding effects of antipsychotic medication can be excluded. Our findings indicate that error prediction signalling and reward anticipation may be linked to striatal dysfunction during prodromal stages and should be examined for their utility in predicting transition risk.
NASA's Asteroid Redirect Mission: Overview and Status
NASA Astrophysics Data System (ADS)
Abell, Paul; Gates, Michele; Johnson, Lindley; Chodas, Paul; Brophy, John; Mazanek, Dan; Muirhead, Brian
A major element of the National Aeronautics and Space Administration’s (NASA) new Asteroid Initiative is the Asteroid Redirect Mission (ARM). This concept was first proposed in 2011 during a feasibility study at the Keck Institute for Space Studies (KISS)[1] and is under consideration for implementation by NASA. The ARM involves sending a high-efficiency (ISP 3000 s), high-power (40 kW) solar electric propulsion (SEP) robotic vehicle that leverages technology developed by NASA’s Space Technology Mission Directorate (STMD) to rendezvous with a near-Earth asteroid (NEA) and return asteroidal material to a stable lunar distant retrograde orbit (LDRO)[2]. There are two mission concepts currently under study, one that captures an entire 7 - 10 meter mean diameter NEA[3], and another that retrieves a 1 - 10 meter mean diameter boulder from a 100+ meter class NEA[4]. Once the retrieved asteroidal material is placed into the LDRO, a two person crew would launch aboard an Orion capsule to rendezvous and dock with the robotic SEP vehicle. After docking, the crew would conduct two extra-vehicular activities (EVA) to collect asteroid samples and deploy instruments prior to Earth return. The crewed portion of the mission is expected to last approximately 25 days and would represent the first human exploration mission beyond low-Earth orbit (LEO) since the Apollo program. The ARM concept leverages NASA’s activities in Human Exploration, Space Technology, and Planetary Defense to accomplish three primary objectives and several secondary objectives. The primary objective relevant to Human Exploration is to gain operational experience with vehicles, systems, and components that will be utilized for future deep space exploration. In regard to Space Technology, the ARM utilizes advanced SEP technology that has high power and long duration capabilities that enable future missions to deep space destinations, such as the Martian system. With respect to Planetary Defense, the ARM mission will utilize an enhanced NEA observation campaign that will detect, track, and characterize both spacecraft mission targets and potentially hazardous asteroids that may threaten Earth in the future. Potential secondary objectives for ARM include planetary defense demonstrations at the NEA, conducting planetary science (both during the robotic and crewed mission segments), and encouraging commercial and international partnership opportunities. References [1] J. Brophy et al., “Asteroid Retrieval Feasibility Study,” Keck Institute for Space Studies Report, April 2012. [2] N. Strange et al., “Overview of Mission Design for NASA Asteroid Redirect Robotic Mission Concept,” presented at the 33rd International Electric Propulsion Conference, The George Washington University, Washington, D.C., October 2013. [3] B. Muirhead, J. Brophy “Asteroid Redirect Robotic Mission Feasibility Study,” presented at IEEE Aerospace Conference, Big Sky, Montana, March 2014. [4] Mazenek et al., “Asteroid Redirect Robotic Mission: Alternate Concept Overview”, American Institute of Aeronautics and Astronautics, Space 2014 Conference, San Diego, California, August 2014.
Association rule mining (ARM) has been widely used to identify associations between various entities in many fields. Although some studies have utilized it to analyze the relationship between chemicals and human health effects, fewer have used this technique to identify and quant...
Light duty utility arm phase 2 qualification test procedure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barnes, G.A.
1997-01-16
This Acceptance Test Procedure (ATP) will test and verify that the Exhauster meets the specified functional requirements, safety requirements, operating requirements, and provide a record of the functional test results. The system/functions that will be tested are listed in the scope section of the Acceptance Test Procedure.
Lo, Yew L; Fook-Chong, Stephanie; Huerto, Antonio P; George, Jane M
2011-07-01
Lumbar spondylosis is a degenerative disorder of the spine, whereby pain is a prominent feature that poses therapeutic challenges even after surgical intervention. There are no randomized, placebo-controlled studies utilizing repetitive spinal magnetic stimulation (SMS) in pain associated with lumbar spondylosis. In this study, we utilize SMS technique for patients with this condition in a pilot clinical trial. We randomized 20 patients into SMS treatment or placebo arms. All patients must have clinical and radiological evidence of lumbar spondylosis. Patients should present with pain in the lumbar region, localized or radiating down the lower limbs in a radicular distribution. SMS was delivered with a Medtronic R30 repetitive magnetic stimulator (Medtronic Corporation, Skovlunde, Denmark) connected to a C-B60 figure of eight coil capable of delivering a maximum output of 2 Tesla per pulse. The coil measured 90 mm in each wing and was centered over the surface landmark corresponding to the cauda equina region. The coil was placed flat over the back with the handle pointing cranially. Each patient on active treatment received 200 trains of five pulses delivered at 10 Hz, at an interval of 5 seconds between each train. "Sham" SMS was delivered with the coil angled vertically and one of the wing edges in contact with the stimulation point. All patients tolerated the procedure well and no side effects of SMS were reported. In the treatment arm, SMS had resulted in significant pain reduction immediately and at Day 4 after treatment (P < 0.05). In the placebo arm, however, no significant pain reduction was seen immediately and at Day 4 after SMS. SMS in the treatment arm had resulted in mean pain reduction of 62.3% postprocedure and 17.4% at Day 4. The placebo arm only achieved pain reduction of 6.1% postprocedure and 4.5% at Day 4. This is the first study to show that a single session of SMS resulted in significant improvement of pain associated with lumbar spondylosis in a randomized, double-blind, placebo-controlled setting. The novel findings support the potential of this technique for future studies pertaining to neuropathic pain. Wiley Periodicals, Inc.
Hatam, Nahid; Askarian, Mehrdad; Javan-Noghabi, Javad; Ahmadloo, Niloofar; Mohammadianpanah, Mohammad
2015-01-01
A cost-utility analysis was performed to assess the cost-utility of neoadjuvant chemotherapy regimens containing doxorubicin and cyclophosphamide (AC) versus paclitaxel and gemcitabine (PG) for locally advanced breast cancer patients in Iran. This cross-sectional study in Namazi hospital in Shiraz, in the south of Iran covered 64 breast cancer patients. According to the random numbers, the patients were divided into two groups, 32 receiving AC and 32 PG. Costs were identified and measured from a community perspective. These items included medical and non-medical direct and indirect costs. In this study, a data collection form was used. To assess the utility of the two regimens, the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire-Core30 (EORTC QLQ-C30) was applied. Using a decision tree, we calculated the expected costs and quality adjusted life years (QALYs) for both methods; also, the incremental cost-effectiveness ratio was assessed. The results of the decision tree showed that in the AC arm, the expected cost was 39,170 US$ and the expected QALY was 3.39 and in the PG arm, the expected cost was 43,336 dollars and the expected QALY was 2.64. Sensitivity analysis showed the cost effectiveness of the AC and ICER=-5535 US$. Overall, the results showed that AC to be superior to PG in treatment of patients with breast cancer, being less costly and more effective.
Decoupling Identification for Serial Two-Link Two-Inertia System
NASA Astrophysics Data System (ADS)
Oaki, Junji; Adachi, Shuichi
The purpose of our study is to develop a precise model by applying the technique of system identification for the model-based control of a nonlinear robot arm, under taking joint-elasticity into consideration. We previously proposed a systematic identification method, called “decoupling identification,” for a “SCARA-type” planar two-link robot arm with elastic joints caused by the Harmonic-drive® reduction gears. The proposed method serves as an extension of the conventional rigid-joint-model-based identification. The robot arm is treated as a serial two-link two-inertia system with nonlinearity. The decoupling identification method using link-accelerometer signals enables the serial two-link two-inertia system to be divided into two linear one-link two-inertia systems. The MATLAB®'s commands for state-space model estimation are utilized in the proposed method. Physical parameters such as motor inertias, link inertias, joint-friction coefficients, and joint-spring coefficients are estimated through the identified one-link two-inertia systems using a gray-box approach. This paper describes accuracy evaluations using the two-link arm for the decoupling identification method under introducing closed-loop-controlled elements and varying amplitude-setup of identification-input. Experimental results show that the identification method also works with closed-loop-controlled elements. Therefore, the identification method is applicable to a “PUMA-type” vertical robot arm under gravity.
The effects of the arm swing on biomechanical and physiological aspects of roller ski skating.
Hegge, Ann Magdalen; Ettema, Gertjan; de Koning, Jos J; Rognstad, Asgeir Bakken; Hoset, Martin; Sandbakk, Øyvind
2014-08-01
This study analyzed the biomechanical and physiological effects of the arm swing in roller ski skating, and compared leg-skating (i.e. ski skating without poles) using a pronounced arm swing (SWING) with leg-skating using locked arms (LOCKED). Sixteen elite male cross-country skiers performed submaximal stages at 10, 15 and 20kmh(-1) on a 2% inclined treadmill in the two techniques. SWING demonstrated higher peak push-off forces and a higher force impulse at all speeds, but a longer cycle length only at the highest speed (all P<.05), indicating a lower force effectiveness with SWING at the two lowest speeds. Additionally, the flexion-extension movement in the lower limbs was more pronounced for SWING. Oxygen uptake was higher for SWING at the two lowest speeds (both P<.05) without any differences in blood lactate. At the highest speed, oxygen uptake did not differ between SWING and LOCKED, but the RER, blood lactate and ventilation were lower with SWING (all P<.05). Taken together, these results demonstrate that utilizing the arm swing in roller ski skating increases the ski forces and aerobic energy cost at low and moderate speeds, whereas the greater forces at high speed lead to a longer cycle length and smaller anaerobic contribution. Copyright © 2014 Elsevier B.V. All rights reserved.
Exploiting the Dynamics of Soft Materials for Machine Learning
Hauser, Helmut; Li, Tao; Pfeifer, Rolf
2018-01-01
Abstract Soft materials are increasingly utilized for various purposes in many engineering applications. These materials have been shown to perform a number of functions that were previously difficult to implement using rigid materials. Here, we argue that the diverse dynamics generated by actuating soft materials can be effectively used for machine learning purposes. This is demonstrated using a soft silicone arm through a technique of multiplexing, which enables the rich transient dynamics of the soft materials to be fully exploited as a computational resource. The computational performance of the soft silicone arm is examined through two standard benchmark tasks. Results show that the soft arm compares well to or even outperforms conventional machine learning techniques under multiple conditions. We then demonstrate that this system can be used for the sensory time series prediction problem for the soft arm itself, which suggests its immediate applicability to a real-world machine learning problem. Our approach, on the one hand, represents a radical departure from traditional computational methods, whereas on the other hand, it fits nicely into a more general perspective of computation by way of exploiting the properties of physical materials in the real world. PMID:29708857
Exploiting the Dynamics of Soft Materials for Machine Learning.
Nakajima, Kohei; Hauser, Helmut; Li, Tao; Pfeifer, Rolf
2018-06-01
Soft materials are increasingly utilized for various purposes in many engineering applications. These materials have been shown to perform a number of functions that were previously difficult to implement using rigid materials. Here, we argue that the diverse dynamics generated by actuating soft materials can be effectively used for machine learning purposes. This is demonstrated using a soft silicone arm through a technique of multiplexing, which enables the rich transient dynamics of the soft materials to be fully exploited as a computational resource. The computational performance of the soft silicone arm is examined through two standard benchmark tasks. Results show that the soft arm compares well to or even outperforms conventional machine learning techniques under multiple conditions. We then demonstrate that this system can be used for the sensory time series prediction problem for the soft arm itself, which suggests its immediate applicability to a real-world machine learning problem. Our approach, on the one hand, represents a radical departure from traditional computational methods, whereas on the other hand, it fits nicely into a more general perspective of computation by way of exploiting the properties of physical materials in the real world.
Sutherland, Robert J
2010-06-01
The article by Goodrich-Hunsaker and Hopkins (2010, this issue) takes up an important place among in the recent contributions on the role of the hippocampus in memory. They evaluate the effect of bilateral damage to the hippocampus on performance by human participants in a virtual 8-arm radial maze. The hippocampal damage appears to be highly selective and nearly complete. Exactly as with selective hippocampal damage in rats, the human participants showed a deficit in accurately choosing rewarded versus never-rewarded arms and a deficit in avoiding reentering recently visited arms. The results are triply significant: (1) They provide good support for the idea that the wealth of neurobiological information, from network to synapse to gene, on spatial memory in the rat may apply as a whole to the human hippocampal memory system; (2) They affirm the utility of human virtual task models of rat spatial memory tasks; (3) They support one interpretation of the dampening of the hippocampal functional MRI (fMRI) blood oxygen level-dependent (BOLD) signal during performance of the virtual radial arm maze observed by Astur et al. (2005).
An ARM data-oriented diagnostics package to evaluate the climate model simulation
NASA Astrophysics Data System (ADS)
Zhang, C.; Xie, S.
2016-12-01
A set of diagnostics that utilize long-term high frequency measurements from the DOE Atmospheric Radiation Measurement (ARM) program is developed for evaluating the regional simulation of clouds, radiation and precipitation in climate models. The diagnostics results are computed and visualized automatically in a python-based package that aims to serve as an easy entry point for evaluating climate simulations using the ARM data, as well as the CMIP5 multi-model simulations. Basic performance metrics are computed to measure the accuracy of mean state and variability of simulated regional climate. The evaluated physical quantities include vertical profiles of clouds, temperature, relative humidity, cloud liquid water path, total column water vapor, precipitation, sensible and latent heat fluxes, radiative fluxes, aerosol and cloud microphysical properties. Process-oriented diagnostics focusing on individual cloud and precipitation-related phenomena are developed for the evaluation and development of specific model physical parameterizations. Application of the ARM diagnostics package will be presented in the AGU session. This work is performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344, IM release number is: LLNL-ABS-698645.
Utilization of robotic-arm assisted total knee arthroplasty for soft tissue protection.
Sultan, Assem A; Piuzzi, Nicolas; Khlopas, Anton; Chughtai, Morad; Sodhi, Nipun; Mont, Michael A
2017-12-01
Despite the well-established success of total knee arthroplasty (TKA), iatrogenic ligamentous and soft tissue injuries are infrequent, but potential complications that can have devastating impact on clinical outcomes. These injuries are often related to technical errors and excessive soft tissue manipulation, particularly during bony resections. Recently, robotic-arm assisted TKA was introduced and demonstrated promising results with potential technical advantages over manual surgery in implant positioning and mechanical accuracy. Furthermore, soft tissue protection is an additional potential advantage offered by these systems that can reduce inadvertent human technical errors encountered during standard manual resections. Therefore, due to the relative paucity of literature, we attempted to answer the following questions: 1) does robotic-arm assisted TKA offer a technical advantage that allows enhanced soft tissue protection? 2) What is the available evidence about soft tissue protection? Recently introduced models of robotic-arm assisted TKA systems with advanced technology showed promising clinical outcomes and soft tissue protection in the short- and mid-term follow-up with results comparable or superior to manual TKA. In this review, we attempted to explore this dimension of robotics in TKA and investigate the soft tissue related complications currently reported in the literature.
The Asteroid Redirect Mission (ARM): Exploration of a Former Binary NEA?
NASA Technical Reports Server (NTRS)
Abell, P. A.; Mazanek, D. D.; Reeves, D. M.; Chodas, P. W.; Gates, M. M.; Johnson, L. N.; Ticker, R. L.
2016-01-01
The National Aeronautics and Space Administration (NASA) is developing the Asteroid Redirect Mission (ARM) as a capability demonstration for future human exploration, including use of high-power solar electric propulsion, which allows for the efficient movement of large masses through deep space. The ARM will also demonstrate the capability to conduct proximity operations with natural space objects and crewed operations beyond the security of quick Earth return. The Asteroid Redirect Robotic Mission (ARRM), currently in formulation, will visit a large near-Earth asteroid (NEA), collect a multi-ton boulder from its surface, conduct a demonstration of a slow push planetary defense technique, and redirect the multi-ton boulder into a stable orbit around the Moon. Once returned to cislunar space in the mid-2020s, astronauts aboard an Orion spacecraft will dock with the robotic vehicle to explore the boulder and return samples to Earth. The ARM is part of NASA's plan to advance technologies, capabilities, and spaceflight experience needed for a human mission to the Martian system in the 2030s. The ARM and subsequent availability of the asteroidal material in cis-lunar space, provide significant opportunities to advance our knowledge of small bodies in the synergistic areas of science, planetary defense, and in-situ resource utilization (ISRU). The current reference target for the ARM is NEA (341843) 2008 EV5, which may have been the primary body of a former binary system (Busch et al., 2011; Tardivel et al., 2016). The ARRM will perform several close proximity operations to investigate the NEA and map its surface. A detailed investigation of this object may allow a better understanding of binary NEA physical characteristics and the possible outcomes for their evolution. An overview of the ARM robotic and crewed segments, including mission operations, and a discussion of potential opportunities for participation with the ARM will be provided in this presentation.
Romkema, Sietske; Bongers, Raoul M; van der Sluis, Corry K
2013-01-01
Intermanual transfer may improve prosthetic handling and acceptance if used in training soon after an amputation. The purpose of this study was to determine whether intermanual transfer effects can be detected after training with a myoelectric upper-limb prosthesis simulator. A mechanistic, randomized, pretest-posttest design was used. A total of 48 right-handed participants (25 women, 23 men) who were able-bodied were randomly assigned to an experimental group or a control group. The experimental group performed a training program of 5 days' duration using the prosthesis simulator. To determine the improvement in skill, a test was administered before, immediately after, and 6 days after training. The control group only performed the tests. Training was performed with the unaffected arm, and tests were performed with the affected arm (the affected arm simulating an amputated limb). Half of the participants were tested with the dominant arm and half with the nondominant arm. Initiation time was defined as the time from starting signal until start of the movement, movement time was defined as the time from the beginning of the movement until completion of the task, and force control was defined as the maximal applied force on a deformable object. The movement time decreased significantly more in the experimental group (F₂,₉₂=7.42, P=.001, η²(G)=.028) when compared with the control group. This finding is indicative of faster handling of the prosthesis. No statistically significant differences were found between groups with regard to initiation time and force control. We did not find a difference in intermanual transfer between the dominant and nondominant arms. The training utilized participants who were able-bodied in a laboratory setting and focused only on transradial amputations. Intermanual transfer was present in the affected arm after training the unaffected arm with a myoelectric prosthesis simulator, and this effect did not depend on laterality. This effect may improve rehabilitation of patients with an upper-limb amputation.
Hommel, E; Olsen, B; Battelino, T; Conget, I; Schütz-Fuhrmann, I; Hoogma, R; Schierloh, U; Sulli, N; Gough, H; Castañeda, J; de Portu, S; Bolinder, J
2014-10-01
To investigate the impact of continuous glucose monitoring (CGM) on health-related quality of life (HRQOL), treatment satisfaction (TS) medical resource use, and indirect costs in the SWITCH study. SWITCH was a multicentre, randomized, crossover study. Patients with type 1 diabetes (n = 153) using continuous subcutaneous insulin infusion (CSII) were randomized to a 12 month sensor-On/Off or sensor-Off/On sequence (6 months each treatment), with a 4-month washout between periods. HRQOL in children and TS in adults were measured using validated questionnaires. Medical resource utilization data were collected. In adults, TS was significantly higher in the sensor-On arm, and there were significant improvements in ratings for treatment convenience and flexibility. There were no clinically significant differences in children's HRQOL or parents' proxy ratings. The incidence of severe hypoglycaemia, unscheduled visits, or diabetes-related hospitalizations did not differ significantly between the two arms. Adult patients made fewer telephone consultations during the sensor-On arm; children's caregivers made similar numbers of telephone consultations during both arms, and calls were on average only 3 min longer during the sensor-On arm. Regarding indirect costs, children with >70 % sensor usage missed fewer school days, compared with the sensor-Off arm (P = 0.0046) but there was no significant difference in the adults days of work off. The addition of CGM to CSII resulted in better metabolic control without imposing an additional burden on the patient or increased medical resource use, and offered the potential for cost offsets.
Accuracy of digital arm and wrist manometers: clinical implications for the dental hygienist.
Furgeson, Danielle; Mickels-Foster, Nancy
2013-10-01
Utilization of digital manometers chairside is fast becoming a standard of care in dental hygiene education. It is imperative to ensure accurate blood pressure measurements regardless of modality to avoid medical emergencies in the dental chair. This study sought to determine the accuracy of the automated digital arm and wrist cuffs utilized by students in the University of Maine at Augusta, Bangor Campus Dental Health Programs' dental hygiene clinic. After institutional review board approval, 121 subjects were recruited, with 21 excluded for a total of 100 subjects. Subjects were randomly assigned to different test modalities upon check-in. Initial blood pressure measurements were taken with a calibrated aneroid control device by a principal investigator. A second measurement was taken with the randomized arm or wrist manometer 5 minutes later. Investigators were blinded to the modality of test manometer and measurements obtained from the second reading. All readings were taken according to manufacturers' instructions to ensure technique consistency. Data indicated lower readings for each modality from the control for both systolic and diastolic measurements. The differences in the systolic and diastolic readings for the wrist modality were significantly lower than the control with (p= 0.000) and (p=0.000), respectively. Automated digital manometers should be used with caution as a screening tool in the dental setting, particularly when administration of pharmacological agents such as local anesthesia may be used during the course of treatment. These automated modalities should not be used for patients with cardiac or hypertensive conditions.
Coordination of dual robot arms using kinematic redundancy
NASA Technical Reports Server (NTRS)
Suh, Il Hong; Shin, Kang G.
1988-01-01
A method is developed to coordinate the motion of dual robot arms carrying a solid object, where the first robot (leader) grasps one end of the object rigidly and the second robot (follower) is allowed to change its grasping position at the other end of the object along the object surface while supporting the object. It is shown that this flexible grasping is equivalent to the addition of one more degree of freedom (dof), giving the follower more maneuvering capabilities. In particular, motion commands for the follower are generated by using kinematic redundancy. To show the utility and power of the method, an example system with two PUMA 560 robots carrying a beam is analyzed.
Bruhn, Hanne; Bond, Christine M; Elliott, Alison M; Hannaford, Philip C; Lee, Amanda J; McNamee, Paul; Smith, Blair H; Watson, Margaret C; Holland, Richard; Wright, David
2013-01-01
Objectives To compare the effectiveness of pharmacist medication review, with or without pharmacist prescribing, with standard care, for patients with chronic pain. Design An exploratory randomised controlled trial. Setting Six general practices with prescribing pharmacists in Grampian (3) and East Anglia (3). Participants Patients on repeat prescribed pain medication (4815) were screened by general practitioners (GPs), and mailed invitations (1397). 196 were randomised and 180 (92%) completed. Exclusion criteria included: severe mental illness, terminally ill, cancer related pain, history of addiction. Randomisation and intervention Patients were randomised using a remote telephone service to: (1) pharmacist medication review with face-to-face pharmacist prescribing; (2) pharmacist medication review with feedback to GP and no planned patient contact or (3) treatment as usual (TAU). Blinding was not possible. Outcome measures Outcomes were the SF-12v2, the Chronic Pain Grade (CPG), the Health Utilities Index 3 and the Hospital Anxiety and Depression Scale (HADS). Outcomes were collected at 0, 3 and 6 months. Results In the prescribing arm (n=70) two patients were excluded/nine withdrew. In the review arm (n=63) one was excluded/three withdrew. In the TAU arm (n=63) four withdrew. Compared with baseline, patients had an improved CPG in the prescribing arm, 47.7% (21/44; p=0.003) and in the review arm, 38.6% (17/44; p=0.001), but not the TAU group, 31.3% (15/48; ns). The SF-12 Physical Component Score showed no effect in the prescribing or review arms but improvement in TAU (p=0.02). The SF-12 Mental Component Score showed no effect for the prescribing or review arms and deterioration in the TAU arm (p=0.002). HADS scores improved within the prescribing arm for depression (p=0.022) and anxiety (p=0.007), between groups (p=0.022 and p=0.045, respectively). Conclusions This is the first randomised controlled trial of pharmacist prescribing in the UK, and suggests that there may be a benefit for patients with chronic pain. A larger trial is required. Trial registration: www.isrctn.org/ISRCTN06131530. Medical Research Council funding. PMID:23562814
Direct interaction with an assistive robot for individuals with chronic stroke.
Kmetz, Brandon; Markham, Heather; Brewer, Bambi R
2011-01-01
Many robotic systems have been developed to provide assistance to individuals with disabilities. Most of these systems require the individual to interact with the robot via a joystick or keypad, though some utilize techniques such as speech recognition or selection of objects with a laser pointer. In this paper, we describe a prototype system using a novel method of interaction with an assistive robot. A touch-sensitive skin enables the user to directly guide a robotic arm to a desired position. When the skin is released, the robot remains fixed in position. The target population for this system is individuals with hemiparesis due to chronic stroke. The system can be used as a substitute for the paretic arm and hand in bimanual tasks such as holding a jar while removing the lid. This paper describes the hardware and software of the prototype system, which includes a robotic arm, the touch-sensitive skin, a hook-style prehensor, and weight compensation and speech recognition software.
Midha, M; Schmitt, J K; Sclater, M
1999-03-01
To determine the effect of exercise with the wheelchair aerobic fitness trainer (WAFT) on anthropometric indices, conditioning, and endocrine and metabolic parameters in persons with lower extremity disability. Exercise sessions with the WAFT lasted 20 to 30 minutes for two to three sessions. Tertiary-care Veterans Administration medical center. Twelve subjects (3 with quadriplegia, 7 with paraplegia, 1 with cerebrovascular accident, 1 with bilateral above-knee amputation). Anthropometric indices (heart rate, blood pressure, weight, oxygen utilization, body mass index, upper arm and abdominal circumference, arm power) and endocrine and metabolic parameters (fasting serum glucose, lipids, and thyroid function) were determined before and after 10 weeks of exercise with the WAFT. All patients noted improved feelings of well-being after training. Mean resting heart rate, upper arm fat area, and fasting serum cholesterol level decreased significantly. Peak oxygen consumption, midarm circumference, and free thyroxine index increased significantly with training. WAFT improves quality of life, conditioning, and endocrine-metabolic parameters in disabled persons.
Temporal coding of brain patterns for direct limb control in humans.
Müller-Putz, Gernot R; Scherer, Reinhold; Pfurtscheller, Gert; Neuper, Christa
2010-01-01
For individuals with a high spinal cord injury (SCI) not only the lower limbs, but also the upper extremities are paralyzed. A neuroprosthesis can be used to restore the lost hand and arm function in those tetraplegics. The main problem for this group of individuals, however, is the reduced ability to voluntarily operate device controllers. A brain-computer interface provides a non-manual alternative to conventional input devices by translating brain activity patterns into control commands. We show that the temporal coding of individual mental imagery pattern can be used to control two independent degrees of freedom - grasp and elbow function - of an artificial robotic arm by utilizing a minimum number of EEG scalp electrodes. We describe the procedure from the initial screening to the final application. From eight naïve subjects participating online feedback experiments, four were able to voluntarily control an artificial arm by inducing one motor imagery pattern derived from one EEG derivation only.
Forearm versus upper arm grafts for vascular access.
Gage, Shawn M; Lawson, Jeffrey H
2017-03-06
Forearm and upper arm arteriovenous grafts perform similarly in terms of patency and complications. Primary patency at 1 year for forearm arteriovenous grafts versus upper arm grafts ranges from 22%-50% versus 22%-42%, and secondary patency at 1 year ranges from 78%-89% versus 52%-67%), respectively. Secondary patency at 2 years, ranges from 30%-64% versus 35%-60% for forearm and upper arteriovenous graft, respectively. Ample pre-operative planning is essential to improved clinical success and the decision to place a graft at one location versus the other should be based solely on previous access history, physical exam, appropriate venous imaging, and other factors that make up the clinical picture. Operative implant strategies and risk of complications are very similar between the two configurations. Postoperative ischemia due to steal syndrome is a potential complication that requires immediate attention. Utilization of the proximal radial or ulnar artery for inflow for the graft can minimize risk of clinically relevant steal syndrome.
Computing Arm Movements with a Monkey Brainet.
Ramakrishnan, Arjun; Ifft, Peter J; Pais-Vieira, Miguel; Byun, Yoon Woo; Zhuang, Katie Z; Lebedev, Mikhail A; Nicolelis, Miguel A L
2015-07-09
Traditionally, brain-machine interfaces (BMIs) extract motor commands from a single brain to control the movements of artificial devices. Here, we introduce a Brainet that utilizes very-large-scale brain activity (VLSBA) from two (B2) or three (B3) nonhuman primates to engage in a common motor behaviour. A B2 generated 2D movements of an avatar arm where each monkey contributed equally to X and Y coordinates; or one monkey fully controlled the X-coordinate and the other controlled the Y-coordinate. A B3 produced arm movements in 3D space, while each monkey generated movements in 2D subspaces (X-Y, Y-Z, or X-Z). With long-term training we observed increased coordination of behavior, increased correlations in neuronal activity between different brains, and modifications to neuronal representation of the motor plan. Overall, performance of the Brainet improved owing to collective monkey behaviour. These results suggest that primate brains can be integrated into a Brainet, which self-adapts to achieve a common motor goal.
Computing Arm Movements with a Monkey Brainet
Ramakrishnan, Arjun; Ifft, Peter J.; Pais-Vieira, Miguel; Woo Byun, Yoon; Zhuang, Katie Z.; Lebedev, Mikhail A.; Nicolelis, Miguel A.L.
2015-01-01
Traditionally, brain-machine interfaces (BMIs) extract motor commands from a single brain to control the movements of artificial devices. Here, we introduce a Brainet that utilizes very-large-scale brain activity (VLSBA) from two (B2) or three (B3) nonhuman primates to engage in a common motor behaviour. A B2 generated 2D movements of an avatar arm where each monkey contributed equally to X and Y coordinates; or one monkey fully controlled the X-coordinate and the other controlled the Y-coordinate. A B3 produced arm movements in 3D space, while each monkey generated movements in 2D subspaces (X-Y, Y-Z, or X-Z). With long-term training we observed increased coordination of behavior, increased correlations in neuronal activity between different brains, and modifications to neuronal representation of the motor plan. Overall, performance of the Brainet improved owing to collective monkey behaviour. These results suggest that primate brains can be integrated into a Brainet, which self-adapts to achieve a common motor goal. PMID:26158523
Quantitative assessment of arm tremor in people with neurological disorders.
Jeonghee Kim; Parnell, Claire; Wichmann, Thomas; DeWeerth, Stephen P
2016-08-01
Abnormal oscillatory movement (i.e. tremor) is usually evaluated with qualitative assessment by clinicians, and quantified with subjective scoring methods. These methods are often inaccurate. We utilized a quantitative and standardized task based on the Fitts' law to assess the performance of arm movement with tremor by controlling a gyration mouse on a computer. The experiment included the center-out tapping (COT) and rectangular track navigation (RTN) tasks. We report the results of a pilot study in which we collected the performance for healthy participants in whom tremor was simulated by imposing oscillatory movements to the arm with a vibration motor. We compared their movement speed and accuracy with and without the artificial "tremor." We found that the artificial tremor significantly affected the path efficiency for both tasks (COT: 56.8 vs. 46.2%, p <; 0.05; RTN: 94.2 vs. 67.4%, p <; 0.05), and we were able to distinguish the presence of tremor. From this result, we expect to quantify severity of tremor and the effectiveness therapy for tremor patients.
Art concept of STS-88 RMS capture of the FGB
1998-06-23
S98-09020 (21 July 1997) --- The Space Shuttle Endeavour prepares to capture the Functional Cargo Block (FGB) using the shuttle's mechanical arm in this artist's depiction of the first Space Shuttle assembly flight for the International Space Station (ISS), mission STS-88 scheduled to launch in July 1998. The shuttle will carry the first United States-built component for the station, a connecting module called Node 1, and attach it to the already orbiting FGB, which supplies early electrical power and propulsion. The FGB will have been launched about two weeks earlier on a Russian Proton rocket from the Baikonur Cosmodrome, Kazahkstan. Once the FGB is captured using the mechanical arm, astronaut Nancy J. Currie will maneuver the arm to dock the FGB to the conical mating adapter at the top of Node 1 in the Shuttle's cargo bay. In ensuing days, three Extravehicular Activity?s (EVA) by astronauts Jerry L. Ross and James H. Newman will be performed to make power, data and utility connections between the two modules.
Leong, Nelson; Truong, Pauline T; Tankel, Keith; Kwan, Winkle; Weir, Lorna; Olivotto, Ivo A
2017-12-01
To determine whether nodal radiation therapy (RT) for breast cancer using modest hypofractionation (HF) with 2.25 to 2.5 Gy per fraction (fx) was associated with increased patient-reported arm symptoms, compared with conventional fractionation (CF) ≤2 Gy/fx. Two cancer registries were used to identify subjects who received computed tomography-planned nodal RT for pT1-3, pN0-2, M0 breast cancer, from 2007 to 2010 at 2 cancer institutions. After ethics approval, patients were mailed an explanatory letter and the Self-reported Arm Symptom Scale, a validated instrument with 8 questions about arm symptoms and 5 related to activities of daily living. Clinicopathologic characteristics and Self-reported Arm Symptom Scale scores were compared between HF/CF cohorts using nonparametric analysis, χ 2 analysis, and multivariate ordinal regression. Of 1759 patients, 800 (45.5%) returned a completed survey. A total of 708 eligible cases formed the study cohort. Of these, 406 (57%) received HFRT (40 Gy/16 fx, 45 Gy/20 fx), and 302 (43%) received CFRT (45-50 Gy/25 fx, 50.4 Gy/28 fx). Median time interval after RT was 5.7 years. Forty-three percent and 75% of patients received breast-conserving surgery and chemotherapy, respectively. Twenty-two percent received breast boost RT, independent of fractionation. Median age at diagnosis was 59 years (HF) and 53 years (CF) (P<.001). The mean numbers of excised (n=12) and involved (n=3) nodes were similar between fractionation cohorts (P=.44), as were the mean sums of responses in arm symptoms (P=.17) and activities of daily living (P=.85). Patients receiving HF reported lower rates of shoulder stiffness (P=.04), trouble moving the arm (P=.02), and difficulty reaching overhead (P<.01) compared with the CF cohort. There was no difference in self-reported arm swelling or symptoms related to brachial plexopathy. Nodal RT with hypofractionation was not associated with increased patient-reported arm symptoms or functional deficits compared with CF. Subjects treated with CF reported more disability in certain aspects of arm/shoulder function. These data support shorter fractionation utilization when regional nodes are within the therapeutic target. Copyright © 2017 Elsevier Inc. All rights reserved.
Zerfu, Taddese Alemu; Ayele, Henok Taddese; Bogale, Tariku Nigatu
2018-06-01
To investigate the effect of innovative means to distribute LARC on contraceptive use, we implemented a three arm, parallel groups, cluster randomized community trial design. The intervention consisted of placing trained community-based reproductive health nurses (CORN) within health centers or health posts. The nurses provided counseling to encourage women to use LARC and distributed all contraceptive methods. A total of 282 villages were randomly selected and assigned to a control arm (n = 94) or 1 of 2 treatment arms (n = 94 each). The treatment groups differed by where the new service providers were deployed, health post or health center. We calculated difference-in-difference (DID) estimates to assess program impacts on LARC use. After nine months of intervention, the use of LARC methods increased significantly by 72.3 percent, while the use of short acting methods declined by 19.6 percent. The proportion of women using LARC methods increased by 45.9 percent and 45.7 percent in the health post and health center based intervention arms, respectively. Compared to the control group, the DID estimates indicate that the use of LARC methods increased by 11.3 and 12.3 percentage points in the health post and health center based intervention arms. Given the low use of LARC methods in similar settings, deployment of contextually trained nurses at the grassroots level could substantially increase utilization of these methods. © 2018 The Population Council, Inc.
Muthuswamy, M B; Thomas, B N; Williams, D; Dingley, J
2014-09-01
Patients recovering from critical illness especially those with critical illness related neuropathy, myopathy, or burns to face, arms and hands are often unable to communicate by writing, speech (due to tracheostomy) or lip reading. This may frustrate both patient and staff. Two low cost movement tracking systems based around a laptop webcam and a laser/optical gaming system sensor were utilised as control inputs for on-screen text creation software and both were evaluated as communication tools in volunteers. Two methods were used to control an on-screen cursor to create short sentences via an on-screen keyboard: (i) webcam-based facial feature tracking, (ii) arm movement tracking by laser/camera gaming sensor and modified software. 16 volunteers with simulated tracheostomy and bandaged arms to simulate communication via gross movements of a burned limb, communicated 3 standard messages using each system (total 48 per system) in random sequence. Ten and 13 minor typographical errors occurred with each system respectively, however all messages were comprehensible. Speed of sentence formation ranged from 58 to 120s with the facial feature tracking system, and 60-160s with the arm movement tracking system. The average speed of sentence formation was 81s (range 58-120) and 104s (range 60-160) for facial feature and arm tracking systems respectively, (P<0.001, 2-tailed independent sample t-test). Both devices may be potentially useful communication aids in patients in general and burns critical care units who cannot communicate by conventional means, due to the nature of their injuries. Copyright © 2014 Elsevier Ltd and ISBI. All rights reserved.
3D Measurement of Forearm and Upper Arm during Throwing Motion using Body Mounted Sensor
NASA Astrophysics Data System (ADS)
Koda, Hideharu; Sagawa, Koichi; Kuroshima, Kouta; Tsukamoto, Toshiaki; Urita, Kazutaka; Ishibashi, Yasuyuki
The aim of this study is to propose the measurement method of three-dimensional (3D) movement of forearm and upper arm during pitching motion of baseball using inertial sensors without serious consideration of sensor installation. Although high accuracy measurement of sports motion is achieved by using optical motion capture system at present, it has some disadvantages such as the calibration of cameras and limitation of measurement place. Whereas the proposed method for 3D measurement of pitching motion using body mounted sensors provides trajectory and orientation of upper arm by the integration of acceleration and angular velocity measured on upper limb. The trajectory of forearm is derived so that the elbow joint axis of forearm corresponds to that of upper arm. Spatial relation between upper limb and sensor system is obtained by performing predetermined movements of upper limb and utilizing angular velocity and gravitational acceleration. The integration error is modified so that the estimated final position, velocity and posture of upper limb agree with the actual ones. The experimental results of the measurement of pitching motion show that trajectories of shoulder, elbow and wrist estimated by the proposed method are highly correlated to those from the motion capture system within the estimation error of about 10 [%].
Cooling Rate Determination in Additively Manufactured Aluminum Alloy 2219
NASA Astrophysics Data System (ADS)
Brice, Craig A.; Dennis, Noah
2015-05-01
Metallic additive manufacturing processes generally utilize a conduction mode, welding-type approach to create beads of deposited material that can be arranged into a three-dimensional structure. As with welding, the cooling rates in the molten pool are relatively rapid compared to traditional casting techniques. Determination of the cooling rate in the molten pool is critical for predicting the solidified microstructure and resultant properties. In this experiment, wire-fed electron beam additive manufacturing was used to melt aluminum alloy 2219 under different thermal boundary conditions. The dendrite arm spacing was measured in the remelted material, and this information was used to estimate cooling rates in the molten pool based on established empirical relationships. The results showed that the thermal boundary conditions have a significant effect on the resulting cooling rate in the molten pool. When thermal conduction is limited due to a small thermal sink, the dendrite arm spacing varies between 15 and 35 µm. When thermal conduction is active, the dendrite arm spacing varies between 6 and 12 µm. This range of dendrite arm spacing implies cooling rates ranging from 5 to 350 K/s. Cooling rates can vary greatly as thermal conditions change during deposition. A cooling rate at the higher end of the range could lead to significant deviation from microstructural equilibrium during solidification.
Adamovich, Sergei; Fluet, Gerard G.; Merians, Alma S.; Mathai, Abraham; Qiu, Qinyin
2010-01-01
Current neuroscience has identified several constructs to increase the effectiveness of upper extremity rehabilitation. One is the use of progressive, skill acquisition-oriented training. Another approach emphasizes the use of bilateral activities. Building on these principles, this paper describes the design and feasibility testing of a robotic / virtual environment system designed to train the arm of persons who have had strokes. The system provides a variety of assistance modes, scalable workspaces and hand-robot interfaces allowing persons with strokes to train multiple joints in three dimensions. The simulations utilize assistance algorithms that adjust task difficulty both online and offline in relation to subject performance. Several distinctive haptic effects have been incorporated into the simulations. An adaptive master-slave relationship between the unimpaired and impaired arm encourages active movement of the subject's hemiparetic arm during a bimanual task. Adaptive anti-gravity support and damping stabilize the arm during virtual reaching and placement tasks. An adaptive virtual spring provides assistance to complete the movement if the subject is unable to complete the task in time. Finally, haptically rendered virtual objects help to shape the movement trajectory during a virtual placement task. A proof of concept study demonstrated this system to be safe, feasible and worthy of further study. PMID:19666345
Li, Zhe; Baker, Wesley B.; Parthasarathy, Ashwin B.; Ko, Tiffany S.; Wang, Detian; Schenkel, Steven; Durduran, Turgut; Li, Gang; Yodh, Arjun G.
2015-01-01
Abstract. We investigate and assess the utility of a simple scheme for continuous absolute blood flow monitoring based on diffuse correlation spectroscopy (DCS). The scheme calibrates DCS using venous-occlusion diffuse optical spectroscopy (VO-DOS) measurements of arm muscle tissue at a single time-point. A calibration coefficient (γ) for the arm is determined, permitting conversion of DCS blood flow indices to absolute blood flow units, and a study of healthy adults (N=10) is carried out to ascertain the variability of γ. The average DCS calibration coefficient for the right (i.e., dominant) arm was γ=(1.24±0.15)×108 (mL·100 mL−1·min−1)/(cm2/s). However, variability can be significant and is apparent in our site-to-site and day-to-day repeated measurements. The peak hyperemic blood flow overshoot relative to baseline resting flow was also studied following arm-cuff ischemia; excellent agreement between VO-DOS and DCS was found (R2=0.95, slope=0.94±0.07, mean difference=−0.10±0.45). Finally, we show that incorporation of subject-specific absolute optical properties significantly improves blood flow calibration accuracy. PMID:26720870
Asteroid Redirect Mission (ARM) Formulation Assessment and Support Team (FAST) Final Report
NASA Technical Reports Server (NTRS)
Mazanek, Daniel D.; Reeves, David M.; Abell, Paul A.; Asphaug, Erik; Abreu, Neyda M.; Bell, James F.; Bottke, William F.; Britt, Daniel T.; Campins, Humberto; Chodas, Paul W.;
2016-01-01
The Asteroid Redirect Mission (ARM) Formulation Assessment and Support Team (FAST) was a two-month effort, chartered by NASA, to provide timely inputs for mission requirement formulation in support of the Asteroid Redirect Robotic Mission (ARRM) Requirements Closure Technical Interchange Meeting held December 15-16, 2015, to assist in developing an initial list of potential mission investigations, and to provide input on potential hosted payloads and partnerships. The FAST explored several aspects of potential science benefits and knowledge gain from the ARM. Expertise from the science, engineering, and technology communities was represented in exploring lines of inquiry related to key characteristics of the ARRM reference target asteroid (2008 EV5) for engineering design purposes. Specific areas of interest included target origin, spatial distribution and size of boulders, surface geotechnical properties, boulder physical properties, and considerations for boulder handling, crew safety, and containment. In order to increase knowledge gain potential from the mission, opportunities for partnerships and accompanying payloads were also investigated. Potential investigations could be conducted to reduce mission risks and increase knowledge return in the areas of science, planetary defense, asteroid resources and in-situ resource utilization, and capability and technology demonstrations. This report represents the FASTâ€"TM"s final product for the ARM.
Use of the DEKA Arm for amputees with brachial plexus injury: A case series
Fantini, Christopher; Latlief, Gail; Phillips, Samuel; Sasson, Nicole; Sepulveda, Eve
2017-01-01
Objective Patients with upper limb amputation and brachial plexus injuries have high rates of prosthesis rejection. Study purpose is to describe experiences of subjects with transhumeral amputation and brachial plexus injury, who were fit with, and trained to use, a DEKA Arm. Methods This was a mixed-methods study utilizing qualitative (e.g. interview, survey) and quantitative data (e.g. self-report and performance measures). Subject 1, a current prosthesis user, had a shoulder arthrodesis. Subject 2, not a prosthesis user, had a subluxed shoulder. Both were trained in laboratory and participated in a trial of home use. Descriptive analyses of processes and outcomes were conducted. Results Subject 1 was fitted with the transhumeral configuration (HC) DEKA Arm using a compression release stabilized socket. He had 12 hours of prosthetic training and participated in all home study activities. Subject 1 had improved dexterity and prosthetic satisfaction with the DEKA Arm and reported better quality of life (QOL) at the end of participation. Subject 2 was fit with the shoulder configuration (SC) DEKA Arm using a modified X-frame socket. He had 30 hours of training and participated in 3 weeks of home activities. He reported less functional disability at the end of training as compared to baseline, but encountered personal problems and exacerbation of PTSD symptoms and withdrew from home use portion at 3 weeks. Both subjects reported functional benefits from use, and expressed a desire to receive a DEKA Arm in the future. Discussion This paper reported on two different strategies for prosthetic fitting and their outcomes. The advantages and limitations of each approach were discussed. Conclusion Use of both the HC and SC DEKA Arm for patients with TH amputation and brachial plexus injury was reported. Lessons learned may be instructive to clinicians considering prosthetic choices for future cases. PMID:28628623
USDA-ARS?s Scientific Manuscript database
In situ application of heavy metal stabilizing agents has in some cases increased the mobility of target metal contaminants. Mechanistic understandings are necessary to better predict (1) the dynamic short- and long-term response to soil amendments, and (2) the utility of biochars in nonremoval and...
Outcomes of a Structured Education Intervention for Latinas Concerning Breast Cancer and Mammography
ERIC Educational Resources Information Center
Laughman, Anna Bawtinhimer; Boselli, Danielle; Love, Magbis; Steuerwald, Nury; Symanowski, James; Blackley, Kris; Wheeler, Mellisa; Arevalo, Gustavo; Carrizosa, Daniel; Raghavan, Derek
2017-01-01
Objective: This study examined the utility of living room and church-based small group educational sessions on breast cancer and mammography, for under-served Latinas in North Carolina, USA. Design: Non-randomised, single arm design. Setting: A total of 329 self-selected Latinas participated in 31 small group educational classes in church and home…
Low Cost Mars Sample Return Utilizing Dragon Lander Project
NASA Technical Reports Server (NTRS)
Stoker, Carol R.
2014-01-01
We studied a Mars sample return (MSR) mission that lands a SpaceX Dragon Capsule on Mars carrying sample collection hardware (an arm, drill, or small rover) and a spacecraft stack consisting of a Mars Ascent Vehicle (MAV) and Earth Return Vehicle (ERV) that collectively carry the sample container from Mars back to Earth orbit.
Aragon-Ching, Jeanny B
2014-01-01
PREVAIL was a phase III multinational, double-blind, placebo-controlled trial that enrolled chemotherapy-naïve men with metastatic castration-resistant prostate cancer (mCRPC), which showed remarkable improvement in co-primary endpoints with an overall 81% reduction in the risk of radiographic progression, as well as 29% reduction in the risk of death in favor of the enzalutamide arm over placebo. All secondary endpoints including time to subsequent chemotherapy initiation and prostate specific antigen (PSA) progression were in favor of the enzalutamide arm. The results of PREVAIL shows the utility of enzalutamide that would likely soon expand the indication to asymptomatic or minimally symptomatic men with mCRPC not previously treated with chemotherapy. PMID:25080931
Aragon-Ching, Jeanny B
2014-01-01
PREVAIL was a phase III multinational, double-blind, placebo-controlled trial that enrolled chemotherapy-naïve men with metastatic castration-resistant prostate cancer (mCRPC), which showed remarkable improvement in co-primary endpoints with an overall 81% reduction in the risk of radiographic progression, as well as 29% reduction in the risk of death in favor of the enzalutamide arm over placebo. All secondary endpoints including time to subsequent chemotherapy initiation and prostate specific antigen (PSA) progression were in favor of the enzalutamide arm. The results of PREVAIL shows the utility of enzalutamide that would likely soon expand the indication to asymptomatic or minimally symptomatic men with mCRPC not previously treated with chemotherapy.
Interchangeable end effector tools utilized on the protoflight manipulator arm
NASA Technical Reports Server (NTRS)
1987-01-01
A subset of teleoperator and effector tools was designed, fabricated, delivered and successfully demonstrated on the Marshall Space Flight Center (MSFC) protoflight manipulator arm (PFMA). The tools delivered included a rotary power tool with interchangeable collets and two fluid coupling mate/demate tools; one for a Fairchild coupling and the other for a Purolator coupling. An electrical interface connector was also provided for the rotary power tool. A tool set, from which the subset was selected, for performing on-orbit satellite maintenance was identified and conceptionally designed. Maintenance requirements were synthesized, evaluated and prioritized to develop design requirements for a set of end effector tools representative of those needed to provide on-orbit maintenance of satellites to be flown in the 1986 to 2000 timeframe.
Design of an autonomous teleoperated cargo transporting vehicle for lunar base operations
NASA Technical Reports Server (NTRS)
Holt, James; Lao, Tom; Monali, Nkoy
1989-01-01
At the turn of the century NASA plans to begin construction of a lunar base. The base will likely consist of developed areas (i.e., habitation, laboratory, landing and launching sites, power plant) separated from each other due to safety considerations. The Self-Repositioning Track Vehicle (SRTV) was designed to transport cargo between these base facilities. The SRTV operates by using two robotic arms to raise and position segments of track upon which the vehicle travels. The SRTV utilizes the semiautonomous mobility (SAM) method of teleoperation; actuator-controlled interlocking track sections; two robotic arms each with five degrees of freedom; and these materials: titanium for structural members and aluminum for shell members, with the possible use of light-weight, high-strength composites.
Piezoelectric film load cell robot collision detector
Lembke, J.R.
1988-03-15
A piezoelectric load cell which can be utilized for detecting collisions and obstruction of a robot arm end effector includes a force sensing element of metallized polyvinylidene fluoride (PVDF) film. The piezoelectric film sensing element and a resilient support pad are clamped in compression between upper and lower plates. The lower plate has a central recess in its upper face for supporting the support pad and sensing element, while the upper plate has a corresponding central projection formed on its lower face for bearing on the sensing element and support pad. The upper and lower plates are dowelled together for concentric alignment and screwed together. The upper and lower plates are also adapted for mounting between the robot arm wrist and end effector. 3 figs.
Piezoelectric film load cell robot collision detector
Lembke, John R.
1989-04-18
A piezoelectric load cell which can be utilized for detecting collisions and obstruction of a robot arm end effector includes a force sensing element of metallized polyvinylidene fluoride (PVDF) film. The piezoelectric film sensing element and a resilient support pad are clamped in compression between upper and lower plates. The lower plate has a central recess in its upper face for supporting the support pad and sensing element, while the upper plate has a corresponding central projection formed on its lower face for bearing on the sensing element and support pad. The upper and lower plates are dowelled together for concentric alignment and screwed together. The upper and lower plates are also adapted for mounting between the robot arm wrist and end effector.
Piezoelectric film load cell robot collision detector
Lembke, J.R.
1989-04-18
A piezoelectric load cell which can be utilized for detecting collisions and obstruction of a robot arm end effector includes a force sensing element of metallized polyvinylidene fluoride (PVDF) film. The piezoelectric film sensing element and a resilient support pad are clamped in compression between upper and lower plates. The lower plate has a central recess in its upper face for supporting the support pad and sensing element, while the upper plate has a corresponding central projection formed on its lower face for bearing on the sensing element and support pad. The upper and lower plates are doweled together for concentric alignment and screwed together. The upper and lower plates are also adapted for mounting between the robot arm wrist and end effector. 3 figs.
Ismayilova, Leyla; Karimli, Leyla; Sanson, Jo; Gaveras, Eleni; Nanema, Rachel; Tô-Camier, Alexice; Chaffin, Josh
2018-07-01
There is limited evidence about interventions improving child mental health in francophone West Africa. Behavioral mental health interventions alone may have limited effects on children's emotional well-being in families living in abject poverty, especially in low-income countries. This study tests the effects of economic intervention, alone and in combination with a family-focused component, on the mental health of children from ultra-poor households in rural Burkina Faso. The three-arm cluster randomized trial included children in the age range of 10-15 years old (N = 360), from twelve villages in Nord region of Burkina Faso (ClinicalTrial.gov ID: NCT02415933). Villages were randomized (4 villages/120 households per arm) to the waitlist arm, the economic intervention utilizing the Graduation approach (Trickle Up/TU arm), or to the economic strengthening plus family coaching component (TU + arm). Intervention effects were tested using repeated-measures mixed-effects regressions that account for the clustered nature of the data. Children from the TU + arm showed a reduction in depressive symptoms at 12 months (medium effect size Cohen's d = -0.41, p = .001) and 24 months (d = -0.39, p = .025), compared to the control condition and the economic intervention alone (at 12 months d = -0.22, p = .020). Small effect size improvements in self-esteem were detected in the TU + group, compared to the control arm at 12 months (d = 0.21) and to the TU arm at 24 months (d = 0.21). Trauma symptoms significantly reduced in the TU + group at 12 months (Incidence Risk Ratio/IRR = 0.62, 95% CI = 0.41, 0.92, p = .042), compared to the control group. Integrating psychosocial intervention involving all family members with economic empowerment strategies may be an innovative approach for improving emotional well-being among children living in extreme poverty. Copyright © 2018 Elsevier Ltd. All rights reserved.
New Design Concept for an Excavator Arms by Using Composite Material
NASA Astrophysics Data System (ADS)
Solazzi, L.; Assi, A.; Ceresoli, F.
2018-06-01
The purpose of the present paper is to lightweight design an excavator arms, by using a different materials and in particular composite material. Specifically, the research is based on the study of a commercial excavator, by determining its geometry and analyzing the load conditions to which it is exposed. These are determined in relation to either the load diagram of the machine or the possible utilities of the excavator, such as the rotation of the machine. The materials used and implemented in the different analytical and numerical elaborations are classic construction steel S 355 (UNI EN 10025-3), high-resistance steel S 890 (UNI EN 10025-6), aluminum Al 6063 T6 (UNI EN 573-3) and the composite material made by carbon fiber and epoxy resin. The adopted constraints for the design of new arms with different materials, non-conventional for these applications, are numerous. The new solutions must present a safety factor either with respect to the yield tensile strength or to the critical load of buckling greater than or equal to the one determined for the excavator in its original geometrical conformation. Another criterion, which has heavily conditioned the geometry of the arms, was given by the fact that the developed solutions must present a very similar value of the maximum displacement in the different load conditions analyzed. A new geometry for arms made by composite material was developed. It was an elliptical conic section, instead of the classic rectangular section, in order to use the filament winding technological process. As for the adoption of the composite material, we focused on the study and the design of this material as long as the interaction with the extremities (made of aluminum) which are interfaced either with the link between the arms or with the elements of the hydraulic plant which serves for the arms movement. From the results developed, it emerges that the solution developed by adopting composite materials is the one that permits the maximum weight reduction for all arms, about 68.1%, which can be seen as an increment of the maximum mass transportable about 45.5% i.e. passing from 5000 kg to 7277 kg.
Anthropomorphic Telemanipulation System in Terminus Control Mode
NASA Technical Reports Server (NTRS)
Jau, Bruno M.; Lewis, M. Anthony; Bejczy, Antal K.
1994-01-01
This paper describes a prototype anthropomorphic kinesthetic telepresence system that is being developed at JPL. It utilizes dexterous terminus devices in the form of an exoskeleton force-sensing master glove worn by the operator and a replica four finger anthropomorphic slave hand. The newly developed master glove is integrated with our previously developed non-anthropomorphic six degree of freedom (DOF) universal force-reflecting hand controller (FRHC). The mechanical hand and forearm are mounted to an industrial robot (PUMA 560), replacing its standard forearm. The notion of 'terminus control mode' refers to the fact that only the terminus devices (glove and robot hand) are of anthropomorphic nature, and the master and slave arms are non-anthropomorphic. The system is currently being evaluated, focusing on tool handling and astronaut equivalent task executions. The evaluation revealed the system's potential for tool handling but it also became evident that hand tool manipulations and space operations require a dual arm robot. This paper describes the system's principal components, its control and computing architecture, discusses findings of the tool handling evaluation, and explains why common tool handling and EVA space tasks require dual arm robots.
Lake Sturgeon, Acipenser fulvescens, movements in Rainy Lake, Minnesota and Ontario
Adams, W.E.; Kallemeyn, L.W.; Willis, D.W.
2006-01-01
Rainy Lake, Minnesota-Ontario, contains a native population of Lake Sturgeon (Acipenser fulvescens) that has gone largely unstudied. The objective of this descriptive study was to summarize generalized Lake Sturgeon movement patterns through the use of biotelemetry. Telemetry data reinforced the high utilization of the Squirrel Falls geographic location by Lake Sturgeon, with 37% of the re-locations occurring in that area. Other spring aggregations occurred in areas associated with Kettle Falls, the Pipestone River, and the Rat River, which could indicate spawning activity. Movement of Lake Sturgeon between the Seine River and the South Arm of Rainy Lake indicates the likelihood of one integrated population on the east end of the South Arm. The lack of re-locations in the Seine River during the months of September and October may have been due to Lake Sturgeon moving into deeper water areas of the Seine River and out of the range of radio telemetry gear or simply moving back into the South Arm. Due to the movements between Minnesota and Ontario, coordination of management efforts among provincial, state, and federal agencies will be important.
Robust model-based 3d/3D fusion using sparse matching for minimally invasive surgery.
Neumann, Dominik; Grbic, Sasa; John, Matthias; Navab, Nassir; Hornegger, Joachim; Ionasec, Razvan
2013-01-01
Classical surgery is being disrupted by minimally invasive and transcatheter procedures. As there is no direct view or access to the affected anatomy, advanced imaging techniques such as 3D C-arm CT and C-arm fluoroscopy are routinely used for intra-operative guidance. However, intra-operative modalities have limited image quality of the soft tissue and a reliable assessment of the cardiac anatomy can only be made by injecting contrast agent, which is harmful to the patient and requires complex acquisition protocols. We propose a novel sparse matching approach for fusing high quality pre-operative CT and non-contrasted, non-gated intra-operative C-arm CT by utilizing robust machine learning and numerical optimization techniques. Thus, high-quality patient-specific models can be extracted from the pre-operative CT and mapped to the intra-operative imaging environment to guide minimally invasive procedures. Extensive quantitative experiments demonstrate that our model-based fusion approach has an average execution time of 2.9 s, while the accuracy lies within expert user confidence intervals.
Art concept, line drawing and Service Module of the ISS
1998-04-13
S98-04904 (21 July 1997) --- The Space Shuttle Endeavour prepares to capture the Functional Cargo Block (FGB) using the shuttle's mechanical arm in this artist's depiction of the first Space Shuttle assembly flight for the International Space Station (ISS), mission STS-88 scheduled to launch in December 1998. The shuttle will carry the first United States-built component for the station, a connecting module called Node 1 or Unity, and attach it to the already orbiting FGB, which supplies early electrical power and propulsion. The FGB, Zarya, will have been launched about two weeks earlier on a Russian Proton rocket from the Baikonur Cosmodrome, Kazahkstan. Once the FGB is captured using the mechanical arm, astronaut Nancy J. Currie will maneuver the arm to dock the FGB to the conical mating adapter at the top of Node 1 in the Shuttle's cargo bay. In ensuing days, three Extravehicular Activity?s (EVA) by astronauts Jerry L. Ross and James H. Newman will be performed to make power, data and utility connections between the two modules.
ERIC Educational Resources Information Center
Chan, Randolph C. H.; Mak, Winnie W. S.; Pang, Ingrid H. Y.; Wong, Samuel Y. S.; Tang, Wai Kwong; Lau, Joseph T. F.; Woo, Jean; Lee, Diana T. F.; Cheung, Fanny M.
2018-01-01
The present study examined whether, when, and how motivational messaging can boost the response rate of postal surveys for physicians based on Higgin's regulatory focus theory, accounting for its cost-effectiveness. A three-arm, blinded, randomized controlled design was used. A total of 3,270 doctors were randomly selected from the registration…
Swerdlow, Daniel R; Cleary, Kevin; Wilson, Emmanuel; Azizi-Koutenaei, Bamshad; Monfaredi, Reza
2017-04-01
Ultrasound imaging requires trained personnel. Advances in robotics and data transmission create the possibility of telesonography. This review introduces clinicians to current technical work in and potential applications of this developing capability. Telesonography offers advantages in hazardous or remote environments. Robotically assisted ultrasound can reduce stress injuries in sonographers and has potential utility during robotic surgery and interventional procedures.
The Regional Response to the Crisis in Colombia
2003-06-01
and Tupac Amaru.38 Additionally, a well documented arms trafficking scandal was serious enough to contribute to the downfall of President Alberto ...enforcement presence along the Colombian border is further bolstered 74 Joao Filho and Daniel Zirker...incursion. Under President Alberto Fujimori (1990-2000), the stance of Peru was very much hard-line. Fujimori made clear his willingness to utilize
Utilization of Genomic Signatures to Direct Use of Primary Chemotherapy in Early Stage Breast Cancer
2012-07-01
those seen with standard dose AC and TC By chemotherapy: AC: 11 of 19 with grade 3 or 4 adverse events (all neutropenia except one treatment...unrelated PE) TC: 8 of 20 with grade 3 or 4 adverse events (all neutropenia except one docetaxel reaction) By arm: Genomically-guided: 14
Chandra, Arunchandra S.; Zhang, Chidong; Klein, Stephen A.; ...
2015-09-10
Here, this study evaluates the ability of the Community Atmospheric Model version 5 (CAM5) to reproduce low clouds observed by the Atmospheric Radiation Measurement (ARM) cloud radar at Manus Island of the tropical western Pacific during the Years of Tropical Convection. Here low clouds are defined as clouds with their tops below the freezing level and bases within the boundary layer. Low-cloud statistics in CAM5 simulations and ARM observations are compared in terms of their general occurrence, mean vertical profiles, fraction of precipitating versus nonprecipitating events, diurnal cycle, and monthly time series. Other types of clouds are included to putmore » the comparison in a broader context. The comparison shows that the model overproduces total clouds and their precipitation fraction but underestimates low clouds in general. The model, however, produces excessive low clouds in a thin layer between 954 and 930 hPa, which coincides with excessive humidity near the top of the mixed layer. This suggests that the erroneously excessive low clouds stem from parameterization of both cloud and turbulence mixing. The model also fails to produce the observed diurnal cycle in low clouds, not exclusively due to the model coarse grid spacing that does not resolve Manus Island. Lastly, this study demonstrates the utility of ARM long-term cloud observations in the tropical western Pacific in verifying low clouds simulated by global climate models, illustrates issues of using ARM observations in model validation, and provides an example of severe model biases in producing observed low clouds in the tropical western Pacific.« less
Robotic right middle lobectomy with a subxiphoid utility port.
Jayakumar, Shruti; Nardini, Marco; Papoulidis, Pavlos; Dunning, Joel
2018-06-01
We present the case of a 74-year-old man with Stage IIa pulmonary adenocarcinoma, for which he underwent a robotic right middle lobectomy. A 4-armed, 5-port approach was used. Four intercostal ports were created above the ninth rib using the Cerfolio's technique. The subxiphoid port was created in the midline, 5 cm down from the xiphisternum. The robot offers higher image quality, depth perception and improved articulation of the instruments, allowing for more accurate dissection and stitching. The usage of a subxiphoid utility port reduces the clashing between instruments, offers a good angle for stapling and provides a direct view of the instruments entering into the chest. Specimen removal through the subxiphoid port may reduce postoperative pain and enhance patient recovery. The use of the subxiphoid approach as a utility port for robotic surgery is promising and may be a suitable replacement for the traditional utility port.
Cockpit Resource Management (CRM) training in the 349th military airlift wing
NASA Technical Reports Server (NTRS)
Halliday, John T.; Biegalski, Conrad S.; Inzana, Anthony
1987-01-01
CRM training can be done on a limited budget. It seems that everyone has a special name for their CRM program. A new program was created and entitled, Aircrew Resource Management (ARM) to emphasize the use of the full resources on our aircraft. That is meant to specifically include the loadmasters. The name also emphasizes the concept that all crewmembers are responsible for safe completion of the trip. The loadmasters have been the brightest students to date. They are a classic under-utilized resource. Together, their crew position has been credited with more ARM saves than the engineers and pilots. The seminar-based program is run by two seminar facilitators that is reinforced by Line Oriented Flight Training sessions run by the active-duty counterparts.
FIBER AND INTEGRATED OPTICS: Integrated optical passive ring resonator for optical gyroscopes
NASA Astrophysics Data System (ADS)
Baĭborodin, Yu V.; Dyadin, S. S.; Lyadenko, A. F.; Mashchenko, A. I.; Ul'yanov, I. A.; Fatin, Yu L.
1992-02-01
A passive ring resonator based on channel waveguides, formed in a K8 glass substrate by diffusion ion exchange in molten potassium nitrate, was made and investigated. The waveguide structure of the resonator included a ring waveguide as well as two Y-type couplers, whose symmetric arms were coupled to the ring waveguide, whereas homogeneous arms were coupled to an external laser and a photodetector. The coupling of the external devices to the channel waveguides was implemented by prisms and butt (end face) contacts. The transfer function of the ring resonator was determined experimentally in order to illustrate its resonant properties and sharpness. Estimates were obtained of the ultimate sensitivity of an optical gyroscope utilizing a ring resonator with the properties described above and ways of improving this sensitivity were analyzed.
NASA Astrophysics Data System (ADS)
Back, B. B.; Baker, M. D.; Barton, D. S.; Basilev, S.; Baum, R.; Betts, R. R.; Białas, A.; Bindel, R.; Bogucki, W.; Budzanowski, A.; Busza, W.; Carroll, A.; Ceglia, M.; Chang, Y.-H.; Chen, A. E.; Coghen, T.; Connor, C.; Czyż, W.; Dabrowski, B.; Decowski, M. P.; Despet, M.; Fita, P.; Fitch, J.; Friedl, M.; Gałuszka, K.; Ganz, R.; Garcia, E.; George, N.; Godlewski, J.; Gomes, C.; Griesmayer, E.; Gulbrandsen, K.; Gushue, S.; Halik, J.; Halliwell, C.; Haridas, P.; Hayes, A.; Heintzelman, G. A.; Henderson, C.; Hollis, R.; Hołyński, R.; Hofman, D.; Holzman, B.; Johnson, E.; Kane, J.; Katzy, J.; Kita, W.; Kotuła, J.; Kraner, H.; Kucewicz, W.; Kulinich, P.; Law, C.; Lemler, M.; Ligocki, J.; Lin, W. T.; Manly, S.; McLeod, D.; Michałowski, J.; Mignerey, A.; Mülmenstädt, J.; Neal, M.; Nouicer, R.; Olszewski, A.; Pak, R.; Park, I. C.; Patel, M.; Pernegger, H.; Plesko, M.; Reed, C.; Remsberg, L. P.; Reuter, M.; Roland, C.; Roland, G.; Ross, D.; Rosenberg, L.; Ryan, J.; Sanzgiri, A.; Sarin, P.; Sawicki, P.; Scaduto, J.; Shea, J.; Sinacore, J.; Skulski, W.; Steadman, S. G.; Stephans, G. S. F.; Steinberg, P.; Straczek, A.; Stodulski, M.; Strek, M.; Stopa, Z.; Sukhanov, A.; Surowiecka, K.; Tang, J.-L.; Teng, R.; Trzupek, A.; Vale, C.; van Nieuwenhuizen, G. J.; Verdier, R.; Wadsworth, B.; Wolfs, F. L. H.; Wosiek, B.; Woźniak, K.; Wuosmaa, A. H.; Wysłouch, B.; Zalewski, K.; Żychowski, P.; Phobos Collaboration
2003-03-01
This manuscript contains a detailed description of the PHOBOS experiment as it is configured for the Year 2001 running period. It is capable of detecting charged particles over the full solid angle using a multiplicity detector and measuring identified charged particles near mid-rapidity in two spectrometer arms with opposite magnetic fields. Both of these components utilize silicon pad detectors for charged particle detection. The minimization of material between the collision vertex and the first layers of silicon detectors allows for the detection of charged particles with very low transverse momenta, which is a unique feature of the PHOBOS experiment. Additional detectors include a time-of-flight wall which extends the particle identification range for one spectrometer arm, as well as sets of scintillator paddle and Cherenkov detector arrays for event triggering and centrality selection.
Wideband unbalanced waveguide power dividers and combiners
Halligan, Matthew; McDonald, Jacob Jeremiah; Strassner, II, Bernd H.
2016-05-17
The various technologies presented herein relate to waveguide dividers and waveguide combiners for application in radar systems, wireless communications, etc. Waveguide dividers-combiners can be manufactured in accordance with custom dimensions, as well as in accordance with waveguide standards such that the input and output ports are of a defined dimension and have a common impedance. Various embodiments are presented which can incorporate one or more septum(s), one or more pairs of septums, an iris, an input matching region, a notch located on the input waveguide arm, waveguide arms having stepped transformer regions, etc. The various divider configurations presented herein can be utilized in high fractional bandwidth applications, e.g., a fractional bandwidth of about 30%, and RF applications in the Ka frequency band (e.g., 26.5-40 GHz).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hodges, G.
2005-03-18
There are currently twenty-four Multi-Filter Rotating Shadowband Radiometers (MFRSR) operating within Atmospheric Radiation Measurement (ARM). Eighteen are located within the Southern Great Plains (SGP) region, there is one at each of the North Slope of Alaska (NSA) and Tropical Western Pacific (TWP) sites, and one is part of the instrumentation of the ARM Mobile Facility. At this time there are four sites, all extended facilities within the SGP, that are equipped for a MFRSR but do not have one due to instrument failure and a lack of spare instruments. In addition to the MFRSRs, there are three other MFRSR derivedmore » instruments that ARM operates. They are the Multi-Filter Radiometer (MFR), the Normal Incidence Multi-Filter Radiometer (NIMFR) and the Narrow Field of View (NFOV) radiometer. All are essentially just the head of a MFRSR used in innovative ways. The MFR is mounted on a tower and pointed at the surface. At the SGP Central Facility there is one at ten meters and one at twenty-five meters. The NSA has a MFR at each station, both at the ten meter level. ARM operates three NIMFRs; one is at the SGP Central Facility and one at each of the NSA stations. There are two NFOVs, both at the SGP Central Facility. One is a single channel (870) and the other utilizes two channels (673 and 870).« less
Hommel, Kevin A.; Gray, Wendy N.; Hente, Elizabeth; Loreaux, Katherine; Ittenbach, Richard F.; Maddux, Michele; Baldassano, Robert; Sylvester, Francisco; Crandall, Wallace; Doarn, Charles; Heyman, Melvin B.; Keljo, David; Denson, Lee A.
2015-01-01
Medication nonadherence is a significant health care issue requiring regular behavioral treatment. Lack of sufficient health care resources and patient/family time commitment for weekly treatment are primary barriers to receiving appropriate self-management support. We describe the methodology of the Telehealth Enhancement of Adherence to Medication (TEAM) trial for medication nonadherence in pediatric inflammatory bowel disease (IBD). For this trial, participants 11–18 years of age will be recruited from seven pediatric hospitals and will complete an initial 4-week run in to assess adherence to a daily medication. Those who take less than 90% of their prescribed medication will be randomized. A total of 194 patients with IBD will be randomized to either a telehealth behavioral treatment (TBT) arm or education only (EO) arm. All treatment will be delivered via telehealth video conferencing. Patients will be assessed at baseline, post-treatment, 3-, 6-, and 12-months. We anticipate that participants in the TBT arm will demonstrate a statistically significant improvement at post-treatment and 3-, 6-, and 12-month follow-up compared to participants in the EO arm for both medication adherence and secondary outcomes (i.e., disease severity, patient quality of life, and health care utilization). If efficacious, the TEAM intervention could be disseminated broadly and reduce health care access barriers so that patients could receive much needed self-management intervention. PMID:26003436
NASA Astrophysics Data System (ADS)
Shin, Yong-Wook; Sung, Won Ju; Eknoyan, O.; Madsen, C. K.; Taylor, H. F.
2012-04-01
A polarization-independent four-port wavelength-tunable optical add drop multiplexer (OADM) that utilizes non-polarizing relaxed beam splitters has been analyzed and demonstrated in Ti:LiNbO3 at the 1530 nm wavelength regime. The design utilizes an asymmetric interferometer configuration with strain induced index grating for polarization coupling along its arms that are shifted in position relative to each other. Experimental results of the filter response agree with theoretical predictions. Electrooptic tuning over a range of 15.7 nm at a rate of 0.08 nm/V has been measured. A temporal response < 46 ns to a 20 V step change in tuning voltage has been demonstrated. Fiber-to-fiber insertion loss is ~ 6.5 dB.
Pompili, Assunta; Tomaz, Carlos; Arnone, Benedetto; Tavares, Maria Clotilde; Gasbarri, Antonella
2010-11-12
The results of many studies conducted over the past two decades suggested a role of estrogen on mammal's ability to learn and remember. In the present paper, we analyzed the influence that the endogenous fluctuation of estrogen, naturally present across the different phases of estrous cycle of female rats, can exert over the performance of tasks utilized to assess memory. In particular, we analyzed the performances in an eight arms radial maze task, dependent upon working memory, and in a water maze (WM) task, dependent upon spatial reference memory. The water maze is aversively motivated by the desire to escape onto a safe platform, whereas the radial arm maze (RAM) is motivated by food reward. The difference in reinforcement may affect the speed of learning, the strategy adopted and the necessity for accurate navigation. Therefore, coherent results obtained through the two different tasks can be due to mnemonic factors. The study was conducted during a long period of time, 14 months, utilizing gonadally intact females, without pharmacological and surgical treatments. In order to evaluate the post-acquisition phase we first trained the animals to reach the criterion in performing tasks, and then we submitted them to experimental phase. Our results show that estrogen can have an effect on memory processes, and that this effect may be different in relation to different kinds of memory. In fact, in our study, estrogen selectively improved working memory, but not reference memory, during post-acquisition performance of a RAM task with four baited and four un-baited arms. Moreover, WM performances showed that estrogen have a negative effect on spatial reference memory. (c) 2010 Elsevier B.V. All rights reserved.
The Orbit of the Companion to HD 100453A: Binary-driven Spiral Arms in a Protoplanetary Disk
NASA Astrophysics Data System (ADS)
Wagner, Kevin; Dong, Ruobing; Sheehan, Patrick; Apai, Dániel; Kasper, Markus; McClure, Melissa; Morzinski, Katie M.; Close, Laird; Males, Jared; Hinz, Phil; Quanz, Sascha P.; Fung, Jeffrey
2018-02-01
HD 100453AB is a 10 ± 2 Myr old binary whose protoplanetary disk was recently revealed to host a global two-armed spiral structure. Given the relatively small projected separation of the binary (1.″05, or ∼108 au), gravitational perturbations by the binary seemed to be a likely driving force behind the formation of the spiral arms. However, the orbit of these stars remained poorly understood, which prevented a proper treatment of the dynamical influence of the companion on the disk. We observed HD 100453AB between 2015 and 2017, utilizing extreme adaptive optics systems on the Very Large Telescope and the Magellan Clay Telescope. We combined the astrometry from these observations with published data to constrain the parameters of the binary’s orbit to a = 1.″06 ± 0.″09, e = 0.17±0.07, and i = 32.°5 ± 6.°5. We utilized publicly available ALMA 12CO data to constrain the inclination of the disk, {i}{{disk}}∼ 28^\\circ , which is relatively coplanar with the orbit of the companion and consistent with previous estimates from scattered light images. Finally, we input these constraints into hydrodynamic and radiative transfer simulations to model the structural evolution of the disk. We find that the spiral structure and truncation of the circumprimary disk in HD 100453 are consistent with a companion-driven origin. Furthermore, we find that the primary star’s rotation, its outer disk, and the companion exhibit roughly the same direction of angular momentum, and thus the system likely formed from the same parent body of material.
Kimmel, Allison L; Wang, Jichuan; Scott, Rachel K; Briggs, Linda; Lyon, Maureen E
2015-07-01
Although the human immunodeficiency virus/acquired immunodeficiency syndrome (HIV/AIDS) has become a chronic illness, disease-specific advance care planning has not yet been evaluated for the palliative care needs of adults with HIV/AIDS. This prospective, longitudinal, randomized, two-arm controlled clinical trial aims to test the efficacy of FAmily CEntered advance care planning among adults living with AIDS and/or HIV with co-morbidities on congruence in treatment preferences, healthcare utilization, and quality of life. The FAmily CEntered intervention arm is two face-to-face sessions with a trained, certified facilitator: Session 1) Disease-Specific Advance Care Planning Respecting Choices Interview; Session 2) Completion of advance directive. The Healthy Living Control arm is: Session 1) Developmental/Relationship History; Session 2) Nutrition. Follow-up data will be collected at 3, 6, 12, and 18 months post-intervention. A total of 288 patient/surrogate dyads will be enrolled from five hospital-based, out-patient clinics in Washington, District of Columbia. Participants will be HIV positive and ≥ 21 years of age; surrogates will be ≥ 18 years of age. Exclusion criteria are homicidality, suicidality, psychosis, and impaired cognitive functioning. We hypothesize that this intervention will enhance patient-centered communication with a surrogate decision-maker about end of life treatment preferences over time, enhance patient quality of life and decrease health care utilization. We further hypothesize that this intervention will decrease health disparities for Blacks in completion of advance directives. If proposed aims are achieved, the benefits of palliative care, particularly increased treatment preferences about end-of-life care and enhanced quality of life, will be extended to people living with AIDS. Copyright © 2015 Elsevier Inc. All rights reserved.
Reconnaissance for trace metals in bed sediment, Wright Patman Lake, near Texarkana, Texas
McKee, Paul W.
2001-01-01
Many contaminants can be introduced into the environment by urban and industrial activities. The drainage area of Wright Patman Lake is influenced by these activities. Among the contaminants associated with urban and industrial activities are trace metals such as arsenic, lead, mercury, and zinc. These contaminants are relatively insoluble in water and commonly are found in stream, lake, and reservoir bottom sediment, especially the clays and silts within the sediment.Wright Patman Lake serves as the major potable water supply for the city of Texarkana and surrounding communities. Texarkana, located in the northeastern corner of Texas and the southwestern corner of Arkansas, had a population of about 56,000 in 1998, which reflects an increase of about 3.4 percent from the 1990 census (Ramos, 1999). Texarkana Water Utilities, which manages the water-treatment facilities for Texarkana, proposes to dredge the lake bed near the water intake in the Elliot Creek arm of Wright Patman Lake. It is possible that arsenic, lead, mercury, and other trace metals might be released into the water if the bed sediment is disturbed. Bed sediment in the Elliot Creek arm of the lake, in particular, could contain trace metals because of its proximity to Red River Army Depot and because industrial land use is prevalent in the headwaters of Elliot Creek.The U.S. Geological Survey (USGS), in cooperation with Reconnaissance for Trace Metals in Bed Sediment, Wright Patman Lake, Near Texarkana, Texas In cooperation with the Texarkana Water Utilities conducted a reconnaissance of Wright Patman Lake to collect bed-sediment samples for analysis of trace metals. This report presents trace metal concentrations in bed-sediment samples collected at six sites along the Elliot Creek arm of the lake, one site each in two adjacent arms, and one site near the dam on June 16, 1999 (fig. 1). One bed-sediment sample was collected at each of the nine sites, and one sediment core was collected at each of two of the sites. Trace metal concentrations are compared to sediment-quality guidelines for the protection of aquatic life and to screening levels based on historical trace metal concentrations in bed sediment of Texas reservoirs.
Road to Readiness: Pathways from Low-Income Children's Early Interactions to School Readiness Skills
ERIC Educational Resources Information Center
Martoccio, Tiffany L.; Brophy-Herb, Holly E.; Onaga, Esther E.
2014-01-01
This study utilized data from the Michigan component of the National Early Head Start Research and Evaluation study to examine toddlers' joint attention at 14 months (parent report measure of toddlers' initiating behaviors, e.g., extends arm to show you something he or she is holding, reaches out and gives you a toy he or she has been holding, and…
Navy Pre-Deployment Training at Eglin AFB, Florida Final Environmental Assessment
2004-02-10
Only-Radar ROW Rest of the World RUR Range Utilization Report SACEX Supporting Arms Coordination Exercise LIST OF ACRONYMS AND ABBREVIATIONS...Wildlife Service USGS U.S. Geological Survey UXO Unexploded Ordnance VOC Volatile Organic Compounds WHO World Health Organization Purpose and...Assessment While most deployments are scheduled long in advance, short-notice deployments often occur in response to world crises. The Atlantic Fleet’s
Overview and Updated Status of the Asteroid Redirect Mission (ARM)
NASA Astrophysics Data System (ADS)
Abell, Paul; Mazanek, Daniel D.; Reeves, David M.; Chodas, Paul; Gates, Michele; Johnson, Lindley N.; Ticker, Ronald
2016-10-01
The National Aeronautics and Space Administration (NASA) is developing a mission to visit a large near-Earth asteroid (NEA), collect a multi-ton boulder and regolith samples from its surface, demonstrate a planetary defense technique known as the enhanced gravity tractor, and return the asteroidal material to a stable orbit around the Moon. Once returned to cislunar space in the mid-2020s, astronauts will explore the boulder and return to Earth with samples. This Asteroid Redirect Mission (ARM) is part of NASA's plan to advance the technologies, capabilities, and spaceflight experience needed for a human mission to the Martian system in the 2030s and other destinations, as well as provide other broader benefits. Subsequent human and robotic missions to the asteroidal material would also be facilitated by its return to cislunar space. Although ARM is primarily a capability demonstration mission (i.e., technologies and associated operations), there exist significant opportunities to advance our knowledge of small bodies in the synergistic areas of science, planetary defense, asteroidal resources and in-situ resource utilization (ISRU), and capability and technology demonstrations. Current plans are for the robotic mission to be launched in late 2021 with the crewed mission segment conducted using an Orion capsule via a Space Launch System rocket in 2026. In order to maximize the knowledge return from the mission, NASA is providing accommodations for payloads to be carried on the robotic segment of the mission and also organizing an ARM Investigation Team. The Investigation Team will be comprised of scientists, technologists, and other qualified and interested individuals from US industry, government, academia, and international institutions to help plan the implementation and execution of ARM. The presentation will provide a mission overview and the most recent update concerning the robotic and crewed segments of ARM, including the mission requirements, and potential NEA targets. Details about the mission operations for each segment will also be provided along with a discussion of the potential opportunities associated with the mission.
Boriani, Giuseppe; Da Costa, Antoine; Quesada, Aurelio; Ricci, Renato Pietro; Favale, Stefano; Boscolo, Gabriele; Clementy, Nicolas; Amori, Valentina; Mangoni di S Stefano, Lorenza; Burri, Haran
2017-03-01
The aim of this study was to evaluate the clinical efficacy and safety of remote monitoring in patients with heart failure implanted with a biventricular defibrillator (CRT-D) with advanced diagnostics. The MORE-CARE trial is an international, prospective, multicentre, randomized controlled trial. Within 8 weeks of de novo implant of a CRT-D, patients were randomized to undergo remote checks alternating with in-office follow-ups (Remote arm) or in-office follow-ups alone (Standard arm). The primary endpoint was a composite of death and cardiovascular (CV) and device-related hospitalization. Use of healthcare resources was also evaluated. A total of 865 eligible patients (mean age 66 ± 10 years) were included in the final analysis (437 in the Remote arm and 428 in the Standard arm) and followed for a median of 24 (interquartile range = 15-26) months. No significant difference was found in the primary endpoint between the Remote and Standard arms [hazard ratio 1.02, 95% confidence interval (CI) 0.80-1.30, P = 0.89] or in the individual components of the primary endpoint (P > 0.05). For the composite endpoint of healthcare resource utilization (i.e. 2-year rates of CV hospitalizations, CV emergency department admissions, and CV in-office follow-ups), a significant 38% reduction was found in the Remote vs. Standard arm (incidence rate ratio 0.62, 95% CI 0.58-0.66, P < 0.001) mainly driven by a reduction of in-office visits. In heart failure patients implanted with a CRT-D, remote monitoring did not reduce mortality or risk of CV or device-related hospitalization. Use of healthcare resources was significantly reduced as a result of a marked reduction of in-office visits without compromising patient safety. NCT00885677. © 2016 The Authors. European Journal of Heart Failure published by John Wiley & Sons Ltd on behalf of European Society of Cardiology.
Arm-in-Arm Response Regulator Dimers Promote Intermolecular Signal Transduction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baker, Anna W.; Satyshur, Kenneth A.; Moreno Morales, Neydis
2016-02-01
ABSTRACT Bacteriophytochrome photoreceptors (BphPs) and their cognate response regulators make up two-component signal transduction systems which direct bacteria to mount phenotypic responses to changes in environmental light quality. Most of these systems utilize single-domain response regulators to transduce signals through unknown pathways and mechanisms. Here we describe the photocycle and autophosphorylation kinetics of RtBphP1, a red light-regulated histidine kinase from the desert bacteriumRamlibacter tataouinensis. RtBphP1 undergoes red to far-red photoconversion with rapid thermal reversion to the dark state. RtBphP1 is autophosphorylated in the dark; this activity is inhibited under red light. The RtBphP1 cognate response regulator, theR. tataouinensisbacteriophytochrome response regulatormore » (RtBRR), and a homolog, AtBRR fromAgrobacterium tumefaciens, crystallize unexpectedly as arm-in-arm dimers, reliant on a conserved hydrophobic motif, hFWAhL (where h is a hydrophobic M, V, L, or I residue). RtBRR and AtBRR dimerize distinctly from four structurally characterized phytochrome response regulators found in photosynthetic organisms and from all other receiver domain homodimers in the Protein Data Bank. A unique cacodylate-zinc-histidine tag metal organic framework yielded single-wavelength anomalous diffraction phases and may be of general interest. Examination of the effect of the BRR stoichiometry on signal transduction showed that phosphorylated RtBRR is accumulated more efficiently than the engineered monomeric RtBRR (RtBRR mon) in phosphotransfer reactions. Thus, we conclude that arm-in-arm dimers are a relevant signaling intermediate in this class of two-component regulatory systems. IMPORTANCEBphP histidine kinases and their cognate response regulators comprise widespread red light-sensing two-component systems. Much work on BphPs has focused on structural understanding of light sensing and on enhancing the natural infrared fluorescence of these proteins, rather than on signal transduction or the resultant phenotypes. To begin to address this knowledge gap, we solved the crystal structures of two single-domain response regulators encoded by a region immediately downstream of that encoding BphPs. We observed a previously unknown arm-in-arm dimer linkage. Monomerization via deletion of the C-terminal dimerization motif had an inhibitory effect on net response regulator phosphorylation, underlining the importance of these unusual dimers for signal transduction.« less
Photoelectric radar servo control system based on ARM+FPGA
NASA Astrophysics Data System (ADS)
Wu, Kaixuan; Zhang, Yue; Li, Yeqiu; Dai, Qin; Yao, Jun
2016-01-01
In order to get smaller, faster, and more responsive requirements of the photoelectric radar servo control system. We propose a set of core ARM + FPGA architecture servo controller. Parallel processing capability of FPGA to be used for the encoder feedback data, PWM carrier modulation, A, B code decoding processing and so on; Utilizing the advantage of imaging design in ARM Embedded systems achieves high-speed implementation of the PID algorithm. After the actual experiment, the closed-loop speed of response of the system cycles up to 2000 times/s, in the case of excellent precision turntable shaft, using a PID algorithm to achieve the servo position control with the accuracy of + -1 encoder input code. Firstly, This article carry on in-depth study of the embedded servo control system hardware to determine the ARM and FPGA chip as the main chip with systems based on a pre-measured target required to achieve performance requirements, this article based on ARM chip used Samsung S3C2440 chip of ARM7 architecture , the FPGA chip is chosen xilinx's XC3S400 . ARM and FPGA communicate by using SPI bus, the advantage of using SPI bus is saving a lot of pins for easy system upgrades required thereafter. The system gets the speed datas through the photoelectric-encoder that transports the datas to the FPGA, Then the system transmits the datas through the FPGA to ARM, transforms speed datas into the corresponding position and velocity data in a timely manner, prepares the corresponding PWM wave to control motor rotation by making comparison between the position data and the velocity data setted in advance . According to the system requirements to draw the schematics of the photoelectric radar servo control system and PCB board to produce specially. Secondly, using PID algorithm to control the servo system, the datas of speed obtained from photoelectric-encoder is calculated position data and speed data via high-speed digital PID algorithm and coordinate models. Finally, a large number of experiments verify the reliability of embedded servo control system's functions, the stability of the program and the stability of the hardware circuit. Meanwhile, the system can also achieve the satisfactory of user experience, to achieve a multi-mode motion, real-time motion status monitoring, online system parameter changes and other convenient features.
Land, Stephanie R.; Kopec, Jacek A.; Julian, Thomas B.; Brown, Ann M.; Anderson, Stewart J.; Krag, David N.; Christian, Nicholas J.; Costantino, Joseph P.; Wolmark, Norman; Ganz, Patricia A.
2010-01-01
Purpose Sentinel lymph node resection (SNR) may reduce morbidity while providing the same clinical utility as conventional axillary dissection (AD). National Surgical Adjuvant Breast and Bowel Project (NSABP) B-32 is a randomized phase III trial comparing SNR immediately followed by AD (SNAD) to SNR and subsequent AD if SN is positive. We report the definitive patient-reported outcomes (PRO) comparisons. Patients and Methods Eligible patients had clinically node-negative, operable invasive breast cancer. The PRO substudy included all SN-negative participants enrolled May 2001 to February 2004 at community institutions in the United States (n = 749; 78% age ≥ 50; 87% clinical tumor size ≤ 2.0 cm; 84% lumpectomy; 87% white). They completed questionnaires presurgery, 1 and 2 to 3 weeks postoperatively, and every 6 months through year 3. Arm symptoms, arm use avoidance, activity limitations, and quality of life (QOL) were compared with intent-to-treat two-sample t-tests and repeated measures analyses. Results Arm symptoms were significantly more bothersome for SNAD compared with SNR patients at 6 months (mean, 4.8 v 3.0; P < .001) and at 12 months (3.6 v 2.5; P = .006). Longitudinally, SNAD patients were more likely to experience ipsilateral arm and breast symptoms, restricted work and social activity, and impaired QOL (P ≤ .002 all items). From 12 to 36 months, fewer than 15% of either SNAD or SNR patients reported moderate or greater severity of any given symptom or activity limitation. Conclusion Arm morbidity was greater with SNAD than with SNR. Despite considerable fears about complications from AD for breast cancer, this study demonstrates that initial problems with either surgery resolve over time. PMID:20679600
Thompson, Bradley F; Pingree, Matthew J; Qu, Wenchun; Murthy, Naveen S; Lachman, Nirusha; Hurdle, Mark Friedrich
2018-04-01
Ultrasound is rarely used for guiding lumbosacral epidural steroid injections due to its technical limitations. For example, sonographic imaging lacks the ability to confirm epidural spread and identify vascular uptake. The perceived risk that these limitations pose to human subjects has precluded any large scale clinical trials to date. To compare the accuracy of ultrasound versus fluoroscopic guidance for first sacral transforaminal epidural injections. Cadaveric comparative study using dichotomous outcomes. A fluoroscopy suite and anatomic laboratory at an academic medical center. Four unembalmed adult human cadavers with no history of spinal surgery. Eight sites were injected twice by one interventionalist, using fluoroscopic and ultrasound guidance. In the fluoroscopy arm, contrast spread was assessed using computed tomography. In the ultrasound arm, latex spread was assessed using gross anatomic dissection. Any visible evidence of epidural spread constituted a positive result. Comparison of the success of obtaining epidural contrast flow was the primary outcome measure. Secondary outcome measures included average duration, rate of intravascular uptake, and quantity of intravascular uptake. All injections performed in both the ultrasound arm and the fluoroscopy arm had positive epidural spread. The average duration was 3.03 minutes with fluoroscopy and 4.76 minutes with ultrasound. The rate of intravascular uptake was 37.5% with fluoroscopy and 50% with ultrasound. Within the ultrasound arm, greater intravascular spread and duration variability were recorded. Although ultrasonography can provide reliable image guidance for cannulating the first sacral foramen in cadavers, it would have limited clinical utility due to its inability to visualize relevant neurovascular structures deep to the osseus roof and exclude intravascular uptake. IV. Copyright © 2018 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Azam, Khalide; Cadir, Nureisha; Madeira, Carla; Gillespie, Stephen H; Sabiiti, Wilber
2018-01-01
Tuberculosis (TB) diagnostics are centralised, requiring long-distance transportation of specimens in most resource-limited settings. We evaluated the ability of OMNIgene.SPUTUM (OM-S) to obviate cold-chain transport of TB specimens. A two-arm (same-day and after 5 days sample processing) study was conducted to assess contamination rates and Mycobacterium tuberculosis viability in OM-S-treated samples against the standard decontamination procedure (SDP) in Mozambique, using Lowenstein Jensen (LJ) and mycobacterial growth indicator tube (MGIT) culture and molecular bacterial load assay. 270 specimens were processed using OM-S and SDP in same-day and 5-day arms. Contamination was lower in OM-S-treated than SDP-treated cultures: 12% versus 15% and 2% versus 27% in the same-day and 5-day arms, respectively. M. tuberculosis recovery in OM-S-treated LJ cultures was 10% and 56% higher in the same-day and 5-day arms, respectively, than SDP-treated cultures, but lower in MGIT (52% and 28% lower in the same-day and 5-day arms, respectively). M. tuberculosis viable count was 1log estimated CFU·mL -1 lower in 5-day OM-S-treated sputa. OM-S was more effective at liquefying sputum with a shorter sample processing time: 22 min for culture. OM-S is simple to use and has demonstrated a high potency to suppress contaminants, maintenance of viability at ambient temperatures and higher M. tuberculosis recovery, particularly in the solid LJ cultures. Optimisation of OM-S to achieve higher MGIT culture positivity and shorter time to result will increase its application and utility in the clinical management of TB.
Azam, Khalide; Cadir, Nureisha; Madeira, Carla; Gillespie, Stephen H.; Sabiiti, Wilber
2018-01-01
Tuberculosis (TB) diagnostics are centralised, requiring long-distance transportation of specimens in most resource-limited settings. We evaluated the ability of OMNIgene.SPUTUM (OM-S) to obviate cold-chain transport of TB specimens. A two-arm (same-day and after 5 days sample processing) study was conducted to assess contamination rates and Mycobacterium tuberculosis viability in OM-S-treated samples against the standard decontamination procedure (SDP) in Mozambique, using Lowenstein Jensen (LJ) and mycobacterial growth indicator tube (MGIT) culture and molecular bacterial load assay. 270 specimens were processed using OM-S and SDP in same-day and 5-day arms. Contamination was lower in OM-S-treated than SDP-treated cultures: 12% versus 15% and 2% versus 27% in the same-day and 5-day arms, respectively. M. tuberculosis recovery in OM-S-treated LJ cultures was 10% and 56% higher in the same-day and 5-day arms, respectively, than SDP-treated cultures, but lower in MGIT (52% and 28% lower in the same-day and 5-day arms, respectively). M. tuberculosis viable count was 1log estimated CFU·mL−1 lower in 5-day OM-S-treated sputa. OM-S was more effective at liquefying sputum with a shorter sample processing time: 22 min for culture. OM-S is simple to use and has demonstrated a high potency to suppress contaminants, maintenance of viability at ambient temperatures and higher M. tuberculosis recovery, particularly in the solid LJ cultures. Optimisation of OM-S to achieve higher MGIT culture positivity and shorter time to result will increase its application and utility in the clinical management of TB. PMID:29479537
Ramme, Austin J; Egol, Jonathan; Chang, Gregory; Davidovitch, Roy I; Konda, Sanjit
2017-07-01
Difficulty determining anatomic rotation following intramedullary (IM) nailing of the femur continues to be problematic for surgeons. Clinical exam and fluoroscopic imaging of the hip and knee have been used to estimate femoral version, but are inaccurate. We hypothesize that 3D c-arm imaging can be used to accurately measure femoral version following IM nailing of femur fractures to prevent rotational malreduction. A midshaft osteotomy was created in a femur Sawbone to simulate a transverse diaphyseal fracture. An intramedullary (IM) nail was inserted into the Sawbone femur without locking screws or cephalomedullary fixation. A goniometer was used to simulate four femoral version situations after IM nailing: 20° retroversion, 0° version, 15° anteversion, and 30° anteversion. In each simulated position, 3D c-arm imaging and, for comparison purposes, perfect lateral radiographs of the knee and hip were performed. The femoral version of each simulated 3D and fluoroscopic case was measured and the results were tabulated. The measured version from the 3D c-arm images was 22.25° retroversion, 0.66° anteversion, 19.53° anteversion, and 25.15° anteversion for the simulated cases of 20° retroversion, 0° version, 15° anteversion, and 30° anteversion, respectively. The lateral fluoroscopic views were measured to be 9.66° retroversion, 12.12° anteversion, 20.91° anteversion, and 18.77° anteversion for the simulated cases, respectively. This study demonstrates the utility of a novel intraoperative method to evaluate femur rotational malreduction following IM nailing. The use of 3D c-arm imaging to measure femoral version offers accuracy and reproducibility. Copyright © 2017 Elsevier Ltd. All rights reserved.
Scatter correction using a primary modulator on a clinical angiography C-arm CT system.
Bier, Bastian; Berger, Martin; Maier, Andreas; Kachelrieß, Marc; Ritschl, Ludwig; Müller, Kerstin; Choi, Jang-Hwan; Fahrig, Rebecca
2017-09-01
Cone beam computed tomography (CBCT) suffers from a large amount of scatter, resulting in severe scatter artifacts in the reconstructions. Recently, a new scatter correction approach, called improved primary modulator scatter estimation (iPMSE), was introduced. That approach utilizes a primary modulator that is inserted between the X-ray source and the object. This modulation enables estimation of the scatter in the projection domain by optimizing an objective function with respect to the scatter estimate. Up to now the approach has not been implemented on a clinical angiography C-arm CT system. In our work, the iPMSE method is transferred to a clinical C-arm CBCT. Additional processing steps are added in order to compensate for the C-arm scanner motion and the automatic X-ray tube current modulation. These challenges were overcome by establishing a reference modulator database and a block-matching algorithm. Experiments with phantom and experimental in vivo data were performed to evaluate the method. We show that scatter correction using primary modulation is possible on a clinical C-arm CBCT. Scatter artifacts in the reconstructions are reduced with the newly extended method. Compared to a scan with a narrow collimation, our approach showed superior results with an improvement of the contrast and the contrast-to-noise ratio for the phantom experiments. In vivo data are evaluated by comparing the results with a scan with a narrow collimation and with a constant scatter correction approach. Scatter correction using primary modulation is possible on a clinical CBCT by compensating for the scanner motion and the tube current modulation. Scatter artifacts could be reduced in the reconstructions of phantom scans and in experimental in vivo data. © 2017 American Association of Physicists in Medicine.
Hendrix, J.L.
1995-04-11
A laser initiated ordnance controller apparatus which provides a safe and arm scheme with no moving parts. The safe & arm apparatus provides isolation of firing energy to explosive devices using a combination of polarization isolation and control through acousto-optical deviation of laser energy pulses. The apparatus provides constant monitoring of the systems status and performs 100% built-in-test at any time prior to ordnance ignition without the risk of premature ignition or detonation. The apparatus has a computer controller, a solid state laser, an acousto-optic deflector and RF drive circuitry, built-in-test optics and electronics, and system monitoring capabilities. The optical system is completed from the laser beam power source to the pyrotechnic ordnance through fiber optic cabling, optical splitters and optical connectors. During operation of the apparatus, a command is provided by the computer controller and, simultaneous with laser flashlamp fire, the safe & arm device is opened for approximately 200 microseconds which allows the laser pulse to transmit through the device. The arm signal also energizes the laser power supply and activates the acousto-optical deflector. When the correct fire format command is received, the acousto-optic deflector moves to the selected event channel, and the channel is verified to ensure the system is pointing to the correct position. Laser energy is transmitted through the fiber where an ignitor or detonator designed to be sensitive to optical pulses is fired at the end of the fiber channel. Simultaneous event channels may also be utilized by optically splitting a single event channel. The built-in-test may be performed anytime prior to ordnance ignition. 6 figures.
Controlling a multi-degree of freedom upper limb prosthesis using foot controls: user experience.
Resnik, Linda; Klinger, Shana Lieberman; Etter, Katherine; Fantini, Christopher
2014-07-01
The DEKA Arm, a pre-commercial upper limb prosthesis, funded by the DARPA Revolutionizing Prosthetics Program, offers increased degrees of freedom while requiring a large number of user control inputs to operate. To address this challenge, DEKA developed prototype foot controls. Although the concept of utilizing foot controls to operate an upper limb prosthesis has been discussed for decades, only small-sized studies have been performed and no commercial product exists. The purpose of this paper is to report amputee user perspectives on using three different iterations of foot controls to operate the DEKA Arm. Qualitative data was collected from 36 subjects as part of the Department of Veterans Affairs (VA) Study to Optimize the DEKA Arm through surveys, interviews, audio memos, and videotaped sessions. Three major, interrelated themes were identified using the constant comparative method: attitudes towards foot controls, psychomotor learning and physical experience of using foot controls. Feedback about foot controls was generally positive for all iterations. The final version of foot controls was viewed most favorably. Our findings indicate that foot controls are a viable control option that can enable control of a multifunction upper limb prosthesis (the DEKA Arm). Multifunction upper limb prostheses require many user control inputs to operate. Foot controls offer additional control input options for such advanced devices, yet have had minimal study. This study found that foot controls were a viable option for controlling multifunction upper limb prostheses. Most of the 36 subjects in this study were willing to adopt foot controls to control the multiple degrees of freedom of the DEKA Arm. With training and practice, all users were able to develop the psychomotor skills needed to successfully operate food controls. Some had initial difficulty, but acclimated over time.
NASA Astrophysics Data System (ADS)
Logan, Timothy; Dong, Xiquan; Xi, Baike
2018-02-01
Aerosol particles are of particular importance because of their impacts on cloud development and precipitation processes over land and ocean. Aerosol properties as well as meteorological observations from the Department of Energy Atmospheric Radiation Measurement (ARM) platform situated in the Southern Great Plains (SGP) are utilized in this study to illustrate the dependence of continental cloud condensation nuclei (CCN) number concentration ( N CCN) on aerosol type and transport pathways. ARM-SGP observations from the 2011 Midlatitude Continental Convective Clouds Experiment field campaign are presented in this study and compared with our previous work during the 2009-10 Clouds, Aerosol, and Precipitation in the Marine Boundary Layer field campaign over the current ARM Eastern North Atlantic site. Northerly winds over the SGP reflect clean, continental conditions with aerosol scattering coefficient ( σ sp) values less than 20 Mm-1 and N CCN values less than 100 cm-3. However, southerly winds over the SGP are responsible for the observed moderate to high correlation ( R) among aerosol loading ( σ sp < 60 Mm-1) and N CCN, carbonaceous chemical species (biomass burning smoke), and precipitable water vapor. This suggests a common transport mechanism for smoke aerosols and moisture via the Gulf of Mexico, indicating a strong dependence on air mass type. NASA MERRA-2 reanalysis aerosol and chemical data are moderately to highly correlated with surface ARM-SGP data, suggesting that this facility can represent surface aerosol conditions in the SGP, especially during strong aerosol loading events that transport via the Gulf of Mexico. Future long-term investigations will help to understand the seasonal influences of air masses on aerosol, CCN, and cloud properties over land in comparison to over ocean.
Impact of a surgical site infection reduction strategy after colorectal resection.
Connolly, T M; Foppa, C; Kazi, E; Denoya, P I; Bergamaschi, R
2016-09-01
This study was performed to determine the impact of a surgical site infection (SSI) reduction strategy on SSI rates following colorectal resection. American College of Surgeons National Surgical Quality Improvement Program (NSQIP) data from 2006-14 were utilized and supplemented by institutional review board-approved chart review. The primary end-point was superficial and deep incisional SSI. The inclusion criterion was colorectal resection. The SSI reduction strategy consisted of preoperative (blood glucose, bowel preparation, shower, hair removal), intra-operative (prophylactic antibiotics, antimicrobial incisional drape, wound protector, wound closure technique) and postoperative (wound dressing technique) components. The SSI reduction strategy was prospectively implemented and compared with historical controls (pre-SSI strategy arm). Statistical analysis included Pearson's chi-square test, and Student's t-test performed with spss software. Of 1018 patients, 379 were in the pre-SSI strategy arm, 311 in the SSI strategy arm and 328 were included to test durability. The study arms were comparable for all measured parameters. Preoperative wound class, operation time, resection type and stoma creation did not differ significantly. The SSI strategy arm demonstrated a significant decrease in overall SSI rates (32.19% vs 18.97%) and superficial SSI rates (23.48% vs 8.04%). Deep SSI and organ space rates did not differ. A review of patients testing durability demonstrated continued improvement in overall SSI rates (8.23%). The implementation of an SSI reduction strategy resulted in a 41% decrease in SSI rates following colorectal resection over its initial 3 years, and its durability as demonstrated by continuing improvement was seen over an additional 2 years. Colorectal Disease © 2015 The Association of Coloproctology of Great Britain and Ireland.
Levi, Benjamin; Jayakumar, Prakash; Giladi, Avi; Jupiter, Jesse B.; Ring, David C.; Kowalske, Karen; Gibran, Nicole S.; Herndon, David; Schneider, Jeffrey C.; Ryan, Colleen M.
2015-01-01
Purpose Heterotopic ossification (HO) is a debilitating complication of burn injury; however, incidence and risk factors are poorly understood. In this study we utilize a multicenter database of adults with burn injuries to identify and analyze clinical factors that predict HO formation. Methods Data from 6 high-volume burn centers, in the Burn Injury Model System Database, were analyzed. Univariate logistic regression models were used for model selection. Cluster-adjusted multivariate logistic regression was then used to evaluate the relationship between clinical and demographic data and the development of HO. Results Of 2,979 patients in the database with information on HO that addressed risk factors for development of HO, 98 (3.5%) developed HO. Of these 98 patients, 97 had arm burns, and 96 had arm grafts. Controlling for age and sex in a multivariate model, patients with >30% total body surface area (TBSA) burn had 11.5x higher odds of developing HO (p<0.001), and those with arm burns that required skin grafting had 96.4x higher odds of developing HO (p=0.04). For each additional time a patient went to the operating room, odds of HO increased 30% (OR 1.32, p<0.001), and each additional ventilator day increase odds 3.5% (OR 1.035, p<0.001). Joint contracture, inhalation injury, and bone exposure did not significantly increase odds of HO. Conclusion Risk factors for HO development include >30% TBSA burn, arm burns, arm grafts, ventilator days, and number of trips to the operating room. Future studies can use these results to identify highest-risk patients to guide deployment of prophylactic and experimental treatments. PMID:26496115
HK022 Nun Requires Arginine-Rich Motif Residues Distinct from λ N
Tawk, Caroline S.; Ghattas, Ingrid R.
2015-01-01
ABSTRACT Bacteriophage λ N protein binds boxB RNA hairpins in the nut (N utilization) sites of immediate early λ transcripts and interacts with host factors to suppress transcriptional termination at downstream terminators. In opposition to λ N, the Nun protein of HK022 binds the boxBs of coinfecting λ transcripts, interacts with a similar or identical set of host factors, and terminates transcription to suppress λ replication. Comparison of N-boxB and Nun-boxB nuclear magnetic resonance (NMR) structural models suggests similar interactions, though limited mutagenesis of Nun is available. Here, libraries of Nun's arginine-rich motif (ARM) were screened for the ability to exclude λ coinfection, and mutants were assayed for Nun termination with a boxB plasmid reporter system. Several Nun ARM residues appear to be immutable: Asp26, Arg28, Arg29, Arg32, Trp33, and Arg36. Asp26 and Trp33 appear to be unable to contact boxB and are not found at equivalent positions in λ N ARM. To understand if the requirement of Asp26, Trp33, and Arg36 indicated differences between HK022 Nun termination and λ N antitermination complexes, the same Nun libraries were fused to the activation domain of λ N and screened for clones able to complement N-deficient λ. Mutants were assayed for N antitermination. Surprisingly, Asp26 and Trp33 were still essential when Nun ARM was fused to N. Docking suggests that Nun ARM contacts a hydrophobic surface of the NusG carboxy-terminal domain containing residues necessary for Nun function. These findings indicate that Nun ARM relies on distinct contacts in its ternary complex and illustrate how protein-RNA recognition can evolve new regulatory functions. IMPORTANCE λ N protein interacts with host factors to allow λ nut-containing transcripts to elongate past termination signals. A competing bacteriophage, HK022, expresses Nun protein, which causes termination of λ nut transcripts. λ N and HK022 Nun use similar arginine-rich motifs (ARMs) to bind the same boxB RNAs in nut transcripts. Screening libraries of Nun ARM mutants, both in HK022 Nun and in a λ N fusion, revealed amino acids essential to Nun that could bind one or more host factors. Docking suggests that NusG, which is present in both Nun termination and N antitermination, is a plausible partner. These findings could help understand how transcription elongation is regulated and illustrate how subtle differences allow ARMs to evolve new regulatory functions. PMID:26350130
HK022 Nun Requires Arginine-Rich Motif Residues Distinct from λ N.
Tawk, Caroline S; Ghattas, Ingrid R; Smith, Colin A
2015-11-01
Bacteriophage λ N protein binds boxB RNA hairpins in the nut (N utilization) sites of immediate early λ transcripts and interacts with host factors to suppress transcriptional termination at downstream terminators. In opposition to λ N, the Nun protein of HK022 binds the boxBs of coinfecting λ transcripts, interacts with a similar or identical set of host factors, and terminates transcription to suppress λ replication. Comparison of N-boxB and Nun-boxB nuclear magnetic resonance (NMR) structural models suggests similar interactions, though limited mutagenesis of Nun is available. Here, libraries of Nun's arginine-rich motif (ARM) were screened for the ability to exclude λ coinfection, and mutants were assayed for Nun termination with a boxB plasmid reporter system. Several Nun ARM residues appear to be immutable: Asp26, Arg28, Arg29, Arg32, Trp33, and Arg36. Asp26 and Trp33 appear to be unable to contact boxB and are not found at equivalent positions in λ N ARM. To understand if the requirement of Asp26, Trp33, and Arg36 indicated differences between HK022 Nun termination and λ N antitermination complexes, the same Nun libraries were fused to the activation domain of λ N and screened for clones able to complement N-deficient λ. Mutants were assayed for N antitermination. Surprisingly, Asp26 and Trp33 were still essential when Nun ARM was fused to N. Docking suggests that Nun ARM contacts a hydrophobic surface of the NusG carboxy-terminal domain containing residues necessary for Nun function. These findings indicate that Nun ARM relies on distinct contacts in its ternary complex and illustrate how protein-RNA recognition can evolve new regulatory functions. λ N protein interacts with host factors to allow λ nut-containing transcripts to elongate past termination signals. A competing bacteriophage, HK022, expresses Nun protein, which causes termination of λ nut transcripts. λ N and HK022 Nun use similar arginine-rich motifs (ARMs) to bind the same boxB RNAs in nut transcripts. Screening libraries of Nun ARM mutants, both in HK022 Nun and in a λ N fusion, revealed amino acids essential to Nun that could bind one or more host factors. Docking suggests that NusG, which is present in both Nun termination and N antitermination, is a plausible partner. These findings could help understand how transcription elongation is regulated and illustrate how subtle differences allow ARMs to evolve new regulatory functions. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Voruganti, Teja; Grunfeld, Eva; Jamieson, Trevor; Kurahashi, Allison M; Lokuge, Bhadra; Krzyzanowska, Monika K; Mamdani, Muhammad; Moineddin, Rahim; Husain, Amna
2017-07-18
The management of patients with complex care needs requires the expertise of health care providers from multiple settings and specialties. As such, there is a need for cross-setting, cross-disciplinary solutions that address deficits in communication and continuity of care. We have developed a Web-based tool for clinical collaboration, called Loop, which assembles the patient and care team in a virtual space for the purpose of facilitating communication around care management. The objectives of this pilot study were to evaluate the feasibility of integrating a tool like Loop into current care practices and to capture preliminary measures of the effect of Loop on continuity of care, quality of care, symptom distress, and health care utilization. We conducted an open-label pilot cluster randomized controlled trial allocating patients with advanced cancer (defined as stage III or IV disease) with ≥3 months prognosis, their participating health care team and caregivers to receive either the Loop intervention or usual care. Outcome data were collected from patients on a monthly basis for 3 months. Trial feasibility was measured with rate of uptake, as well as recruitment and system usage. The Picker Continuity of Care subscale, Palliative care Outcomes Scale, Edmonton Symptom Assessment Scale, and Ambulatory and Home Care Record were patient self-reported measures of continuity of care, quality of care, symptom distress, and health services utilization, respectively. We conducted a content analysis of messages posted on Loop to understand how the system was used. Nineteen physicians (oncologists or palliative care physicians) were randomized to the intervention or control arms. One hundred twenty-seven of their patients with advanced cancer were approached and 48 patients enrolled. Of 24 patients in the intervention arm, 20 (83.3%) registered onto Loop. In the intervention and control arms, 12 and 11 patients completed three months of follow-up, respectively. A mean of 1.2 (range: 0 to 4) additional healthcare providers with an average total of 3 healthcare providers participated per team. An unadjusted between-arm increase of +11.4 was observed on the Picker scale in favor of the intervention arm. Other measures showed negligible changes. Loop was primarily used for medical care management, symptom reporting, and appointment coordination. The results of this study show that implementation of Loop was feasible. It provides useful information for planning future studies further examining effectiveness and team collaboration. Numerically higher scores were observed for the Loop arm relative to the control arm with respect to continuity of care. Future work is required to understand the incentives and barriers to participation so that the implementation of tools like Loop can be optimized. ClinicalTrials.gov NCT02372994; https://clinicaltrials.gov/ct2/show/NCT02372994 (Archived by WebCite at http://www.webcitation.org/6r00L4Skb). ©Teja Voruganti, Eva Grunfeld, Trevor Jamieson, Allison M Kurahashi, Bhadra Lokuge, Monika K Krzyzanowska, Muhammad Mamdani, Rahim Moineddin, Amna Husain. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 18.07.2017.
2010-01-01
Background The presence of closely related genomes in polyploid species makes the assembly of total genomic sequence from shotgun sequence reads produced by the current sequencing platforms exceedingly difficult, if not impossible. Genomes of polyploid species could be sequenced following the ordered-clone sequencing approach employing contigs of bacterial artificial chromosome (BAC) clones and BAC-based physical maps. Although BAC contigs can currently be constructed for virtually any diploid organism with the SNaPshot high-information-content-fingerprinting (HICF) technology, it is currently unknown if this is also true for polyploid species. It is possible that BAC clones from orthologous regions of homoeologous chromosomes would share numerous restriction fragments and be therefore included into common contigs. Because of this and other concerns, physical mapping utilizing the SNaPshot HICF of BAC libraries of polyploid species has not been pursued and the possibility of doing so has not been assessed. The sole exception has been in common wheat, an allohexaploid in which it is possible to construct single-chromosome or single-chromosome-arm BAC libraries from DNA of flow-sorted chromosomes and bypass the obstacles created by polyploidy. Results The potential of the SNaPshot HICF technology for physical mapping of polyploid plants utilizing global BAC libraries was evaluated by assembling contigs of fingerprinted clones in an in silico merged BAC library composed of single-chromosome libraries of two wheat homoeologous chromosome arms, 3AS and 3DS, and complete chromosome 3B. Because the chromosome arm origin of each clone was known, it was possible to estimate the fidelity of contig assembly. On average 97.78% or more clones, depending on the library, were from a single chromosome arm. A large portion of the remaining clones was shown to be library contamination from other chromosomes, a feature that is unavoidable during the construction of single-chromosome BAC libraries. Conclusions The negligibly low level of incorporation of clones from homoeologous chromosome arms into a contig during contig assembly suggested that it is feasible to construct contigs and physical maps using global BAC libraries of wheat and almost certainly also of other plant polyploid species with genome sizes comparable to that of wheat. Because of the high purity of the resulting assembled contigs, they can be directly used for genome sequencing. It is currently unknown but possible that equally good BAC contigs can be also constructed for polyploid species containing smaller, more gene-rich genomes. PMID:20170511
DOE Office of Scientific and Technical Information (OSTI.GOV)
Henry, Michael J.; Cramer, Nicholas O.; Benz, Jacob M.
Traditional arms control treaty verification activities typically involve a combination of technical measurements via physical and chemical sensors, state declarations, political agreements, and on-site inspections involving international subject matter experts. However, the ubiquity of the internet, and the electronic sharing of data that it enables, has made available a wealth of open source information with the potential to benefit verification efforts. Open source information is already being used by organizations such as the International Atomic Energy Agency to support the verification of state-declared information, prepare inspectors for in-field activities, and to maintain situational awareness . The recent explosion in socialmore » media use has opened new doors to exploring the attitudes, moods, and activities around a given topic. Social media platforms, such as Twitter, Facebook, and YouTube, offer an opportunity for individuals, as well as institutions, to participate in a global conversation at minimal cost. Social media data can also provide a more data-rich environment, with text data being augmented with images, videos, and location data. The research described in this paper investigates the utility of applying social media signatures as potential arms control and nonproliferation treaty verification tools and technologies, as determined through a series of case studies. The treaty relevant events that these case studies touch upon include detection of undeclared facilities or activities, determination of unknown events recorded by the International Monitoring System (IMS), and the global media response to the occurrence of an Indian missile launch. The case studies examine how social media can be used to fill an information gap and provide additional confidence to a verification activity. The case studies represent, either directly or through a proxy, instances where social media information may be available that could potentially augment the evaluation of an event. The goal of this paper is to instigate a discussion within the verification community as to where and how social media can be effectively utilized to complement and enhance traditional treaty verification efforts. In addition, this paper seeks to identify areas of future research and development necessary to adapt social media analytic tools and techniques, and to form the seed for social media analytics to aid and inform arms control and nonproliferation policymakers and analysts. While social media analysis (as well as open source analysis as a whole) will not ever be able to replace traditional arms control verification measures, they do supply unique signatures that can augment existing analysis.« less
Song, Chiang-Soon
2014-06-01
[Purpose] The purpose of the present study was to examine the effects of task-oriented approach on motor function of the affected arm in children with spastic hemiplegia due to cerebral palsy. [Subjects] Twelve children were recruited by convenience sampling from 2 local rehabilitation centers. The present study utilized a one-group pretest-posttest design. All of children received task-oriented training for 6 weeks (40 min/day, 5 days/week) and also underwent regular occupational therapy. Three clinical tests, Box and Block Test (BBT), Manual Ability Measure (MAM-16), and Wee Functional Independence Measure (WeeFIM) were performed 1 day before and after training to evaluate the effects of the training. [Results] Compared with the pretest scores, there was a significant increase in the BBT, MAM-16, and WeeFIM scores of the children after the 6-week practice period. [Conclusion] The results of this study suggest that a task-oriented approach to treatment of the affected arm improves functional activities, such as manual dexterity and fine motor performance, as well as basic daily activities of patients with spastic hemiplegia due to cerebral palsy.
2010-01-01
Background Methods for the calculation and application of quantitative electromyographic (EMG) statistics for the characterization of EMG data detected from forearm muscles of individuals with and without pain associated with repetitive strain injury are presented. Methods A classification procedure using a multi-stage application of Bayesian inference is presented that characterizes a set of motor unit potentials acquired using needle electromyography. The utility of this technique in characterizing EMG data obtained from both normal individuals and those presenting with symptoms of "non-specific arm pain" is explored and validated. The efficacy of the Bayesian technique is compared with simple voting methods. Results The aggregate Bayesian classifier presented is found to perform with accuracy equivalent to that of majority voting on the test data, with an overall accuracy greater than 0.85. Theoretical foundations of the technique are discussed, and are related to the observations found. Conclusions Aggregation of motor unit potential conditional probability distributions estimated using quantitative electromyographic analysis, may be successfully used to perform electrodiagnostic characterization of "non-specific arm pain." It is expected that these techniques will also be able to be applied to other types of electrodiagnostic data. PMID:20156353
Utilization of a Terrestrial Laser Scanner for the Calibration of Mobile Mapping Systems
Hong, Seunghwan; Park, Ilsuk; Lee, Jisang; Lim, Kwangyong; Choi, Yoonjo; Sohn, Hong-Gyoo
2017-01-01
This paper proposes a practical calibration solution for estimating the boresight and lever-arm parameters of the sensors mounted on a Mobile Mapping System (MMS). On our MMS devised for conducting the calibration experiment, three network video cameras, one mobile laser scanner, and one Global Navigation Satellite System (GNSS)/Inertial Navigation System (INS) were mounted. The geometric relationships between three sensors were solved by the proposed calibration, considering the GNSS/INS as one unit sensor. Our solution basically uses the point cloud generated by a 3-dimensional (3D) terrestrial laser scanner rather than using conventionally obtained 3D ground control features. With the terrestrial laser scanner, accurate and precise reference data could be produced and the plane features corresponding with the sparse mobile laser scanning data could be determined with high precision. Furthermore, corresponding point features could be extracted from the dense terrestrial laser scanning data and the images captured by the video cameras. The parameters of the boresight and the lever-arm were calculated based on the least squares approach and the precision of the boresight and lever-arm could be achieved by 0.1 degrees and 10 mm, respectively. PMID:28264457
Physics and technology of the arms race
NASA Astrophysics Data System (ADS)
Garwin, R. L.
1983-10-01
Traditional military concepts of superiority and effectiveness (as embodied in Lanchester's law) have little relevance to thermonuclear weapons, with their enormous effectiveness in destruction of society. Few are needed to saturate their deterrent effect, but their military effectiveness is limited. The evolution and future of strategic nuclear forces is discussed, and their declining marginal utility emphasized. Some calculatons relevant to the nuclear confrontation are presented (Lanchester's Law; skin effect of VLF and ELF signals to submarines; the rocket equation; simple radar-range equation) and recommendations presented for future strategic forces and arms control initiatives. Recommended programs include a silo-based 12-ton single-warhead missile (SICM), the development of buried-bomb defense of individual Minuteman silos, the completion of the deployment of air-launched cruise missiles on the B-52 fleet, and the development of small (1000-ton) submarines for basing ICBM-range missiles. Limiting the threat by arms control should include ratification of SALT II, followed by negotiation of a protrocool to allow a SICM and dedicated silo to be deployed for each two, SALT-II-allowed warheads given up; a ban on weapons in space and anti-satellite tests; and an eventual reduction to 1000 nuclear warheads in U.S. and Soviet inventories.
Group versus individual family planning counseling in Ghana: a randomized, noninferiority trial.
Schwandt, Hilary M; Creanga, Andreea A; Danso, Kwabena A; Adanu, Richard M K; Agbenyega, Tsiri; Hindin, Michelle J
2013-08-01
Group, rather than individual, family planning counseling has the potential to increase family planning knowledge and use through more efficient use of limited human resources. A randomized, noninferiority study design was utilized to identify whether group family planning counseling is as effective as individual family planning counseling in Ghana. Female gynecology patients were enrolled from two teaching hospitals in Ghana in June and July 2008. Patients were randomized to receive either group or individual family planning counseling. The primary outcome in this study was change in modern contraceptive method knowledge. Changes in family planning use intention before and after the intervention and intended method type were also explored. Comparisons between the two study arms suggest that randomization was successful. The difference in change in modern contraceptive methods known from baseline to follow-up between the two study arms (group-individual), adjusted for study site, was -0.21, (95% confidence interval: -0.53 to 0.12) suggesting no difference between the two arms. Group family planning counseling was as effective as individual family planning counseling in increasing modern contraceptive knowledge among female gynecology patients in Ghana. Copyright © 2013 Elsevier Inc. All rights reserved.
Towards automatic Markov reliability modeling of computer architectures
NASA Technical Reports Server (NTRS)
Liceaga, C. A.; Siewiorek, D. P.
1986-01-01
The analysis and evaluation of reliability measures using time-varying Markov models is required for Processor-Memory-Switch (PMS) structures that have competing processes such as standby redundancy and repair, or renewal processes such as transient or intermittent faults. The task of generating these models is tedious and prone to human error due to the large number of states and transitions involved in any reasonable system. Therefore model formulation is a major analysis bottleneck, and model verification is a major validation problem. The general unfamiliarity of computer architects with Markov modeling techniques further increases the necessity of automating the model formulation. This paper presents an overview of the Automated Reliability Modeling (ARM) program, under development at NASA Langley Research Center. ARM will accept as input a description of the PMS interconnection graph, the behavior of the PMS components, the fault-tolerant strategies, and the operational requirements. The output of ARM will be the reliability of availability Markov model formulated for direct use by evaluation programs. The advantages of such an approach are (a) utility to a large class of users, not necessarily expert in reliability analysis, and (b) a lower probability of human error in the computation.
NASA Astrophysics Data System (ADS)
Montoya, Joseph; Kennerly, Stephen; Rede, Edward
2010-04-01
Utilization of Near-Infrared (NIR) spectral features in a muzzle flash will allow for small arms detection using low cost silicon (Si)-based imagers. Detection of a small arms muzzle flash in a particular wavelength region is dependent on the intensity of that emission, the efficiency of source emission transmission through the atmosphere, and the relative intensity of the background scene. The NIR muzzle flash signature exists in the relatively large Si spectral response wavelength region of 300 nm-1100 nm, which allows for use of commercial-off-the-shelf (COTS) Si-based detectors. The alkali metal origin of the NIR spectral features in the 7.62 × 39-mm round muzzle flash is discussed, and the basis for the spectral bandwidth is examined, using a calculated Voigt profile. This report will introduce a model of the 7.62 × 39-mm NIR muzzle flash signature based on predicted source characteristics. Atmospheric limitations based on NIR spectral regions are investigated in relation to the NIR muzzle flash signature. A simple signal-to-clutter ratio (SCR) metric is used to predict sensor performance based on a model of radiance for the source and solar background and pixel registered image subtraction.
2014-03-21
funding from USDA Foreign Agricultural Service towards the Global Agricultural Monitoring project, DoD Armed Forces Health Surveillance Center’s...Global Emerging Infections Surveillance and Response System (AFHSC/GEIS) under the Human Febrile and Vector -Borne Illnesses (FVBI) Program and USDA ...outbreaks during the 2010?2012 period. We utilized 2000?2012 vegetation index and land surface temperature data from NASA ?s satellitebased Moderate
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jonathan Helmus, Scott Collis
The Python-ARM Radar Toolkit (Py-ART) is a collection of radar quality control and retrieval codes which all work on two unifying Python objects: the PyRadar and PyGrid objects. By building ingests to several popular radar formats and then abstracting the interface Py-ART greatly simplifies data processing over several other available utilities. In addition Py-ART makes use of Numpy arrays as its primary storage mechanism enabling use of existing and extensive community software tools.
Portable obstructive sleep apnea detection and mobile monitoring
NASA Astrophysics Data System (ADS)
Demirkol ćakmak, Duygu; Eyüboǧlu, B. Murat
2017-05-01
Obstructive sleep apnea syndrome is becoming a prevalent disease for both adults and children. It is described as the cessation of breath for at least 10 seconds during sleep. Detecting sleep apnea is considered as a troublesome and timeconsuming method, which requires the patients to stay one or more nights in dedicated sleep disorder rooms with sensors physically attached to their body. Undiagnosed thereby untreated sleep apnea patients are under high risk of hypertension, heart attack, traffic accident through fatigue and sleeplessness. In this project, nasal and oral respiratory information is obtained with utilizing thermocouple and oxygen saturation in the blood is obtained with utilizing pulse oximeter. An analog hardware circuit is designed to readout thermocouple and pulse oximeter signals. According to this respiratory and pulse oximetry signals, obstructive sleep apnea is detected in real time with using a software implemented into an ARM based processor. An Android mobile application is developed to record and display the oxygen saturation, heart rate and respiratory signal data during sleep. ARM based processor and mobile application communication is established via Bluetooth interface to reduce cabling on the patient. In summary, a portable, low cost and user friendly device to detect obstructive sleep apnea which is able to share the necessary information to the patients and doctors for the duration of the whole sleep cycle is developed.
Family Access to a Dentist Study (FADS): A Multi-Center Randomized Controlled Trial
Nelson, Suchitra; Riedy, Christine; Albert, Jeffrey M; Lee, Wonik; Slusar, Mary Beth; Curtan, Shelley; Ferretti, Gerald; Cunha-Cruz, Joana; Milgrom, Peter
2015-01-01
Introduction Many low-income parent/caregivers do not understand the importance of cavity-free primary (baby) teeth and the chronic nature of dental caries (tooth decay). As a consequence, dental preventive and treatment utilization is low even when children are screened in schools and referred for care. This study aims to test a referral letter and Dental Information Guide (DIG) designed using the Common-Sense Model of Self-Regulation (CSM) framework to improve caregivers’ illness perception of dental caries and increase utilization of care by children with restorative dental needs. Methods A multi-site randomized controlled trial with caregivers of Kindergarten to 4th grade children in urban Ohio and rural Washington State will compare five arms: (1) CSM referral letter alone; (2) CSM referral letter + DIG; (3) reduced CSM referral letter alone; (4) reduced CSM referral letter + DIG; (5) standard (control) referral. At baseline, children will be screened at school to determine restorative dental needs. If in need of treatment, caregivers will be randomized to study arms and an intervention packet will be sent home. The primary outcome will be dental care based on a change in oral health status by clinical examination 7 months post-screening (ICDAS sealant codes 1 and 2; restoration codes 3–8; extraction). Enrollment commenced summer 2015 with results in summer 2016. Conclusion This study uses the CSM framework to develop and test behavioral interventions to increase dental utilization among low-income caregivers. If effective this simple intervention has broad applicability in clinical and community-based settings. PMID:26500170
Family Access to a Dentist Study (FADS): A multi-center randomized controlled trial.
Nelson, Suchitra; Riedy, Christine; Albert, Jeffrey M; Lee, Wonik; Slusar, Mary Beth; Curtan, Shelley; Ferretti, Gerald; Cunha-Cruz, Joana; Milgrom, Peter
2015-11-01
Many low-income parent/caregivers do not understand the importance of cavity-free primary (baby) teeth and the chronic nature of dental caries (tooth decay). As a consequence, dental preventive and treatment utilization is low even when children are screened in schools and referred for care. This study aims to test a referral letter and Dental Information Guide (DIG) designed using the Common-Sense Model of Self-Regulation (CSM) framework to improve caregivers' illness perception of dental caries and increase utilization of care by children with restorative dental needs. A multi-site randomized controlled trial with caregivers of Kindergarten to 4th grade children in urban Ohio and rural Washington State will compare five arms: (1) CSM referral letter alone; (2) CSM referral letter+DIG; (3) reduced CSM referral letter alone; (4) reduced CSM referral letter+DIG; and (5) standard (control) referral. At baseline, children will be screened at school to determine restorative dental needs. If in need of treatment, caregivers will be randomized to study arms and an intervention packet will be sent home. The primary outcome will be dental care based on a change in oral health status by clinical examination 7 months post-screening (ICDAS sealant codes 1 and 2; restoration codes 3-8; extraction). Enrollment commenced summer 2015 with results in summer 2016. This study uses the CSM framework to develop and test behavioral interventions to increase dental utilization among low-income caregivers. If effective this simple intervention has broad applicability in clinical and community-based settings. Copyright © 2015 Elsevier Inc. All rights reserved.
Nielsen, Joachim; Holmberg, Hans-Christer; Schrøder, Henrik D; Saltin, Bengt; Ørtenblad, Niels
2011-01-01
Abstract Although glycogen is known to be heterogeneously distributed within skeletal muscle cells, there is presently little information available about the role of fibre types, utilization and resynthesis during and after exercise with respect to glycogen localization. Here, we tested the hypothesis that utilization of glycogen with different subcellular localizations during exhaustive arm and leg exercise differs and examined the influence of fibre type and carbohydrate availability on its subsequent resynthesis. When 10 elite endurance athletes (22 ± 1 years, = 68 ± 5 ml kg−1 min−1, mean ± SD) performed one hour of exhaustive arm and leg exercise, transmission electron microscopy revealed more pronounced depletion of intramyofibrillar than of intermyofibrillar and subsarcolemmal glycogen. This phenomenon was the same for type I and II fibres, although at rest prior to exercise, the former contained more intramyofibrillar and subsarcolemmal glycogen than the latter. In highly glycogen-depleted fibres, the remaining small intermyofibrillar and subsarcolemmal glycogen particles were often found to cluster in groupings. In the recovery period, when the athletes received either a carbohydrate-rich meal or only water the impaired resynthesis of glycogen with water alone was associated primarily with intramyofibrillar glycogen. In conclusion, after prolonged high-intensity exercise the depletion of glycogen is dependent on subcellular localization. In addition, the localization of glycogen appears to be influenced by fibre type prior to exercise, as well as carbohydrate availability during the subsequent period of recovery. These findings provide insight into the significance of fibre type-specific compartmentalization of glycogen metabolism in skeletal muscle during exercise and subsequent recovery. PMID:21486810
Hommel, Kevin A; Gray, Wendy N; Hente, Elizabeth; Loreaux, Katherine; Ittenbach, Richard F; Maddux, Michele; Baldassano, Robert; Sylvester, Francisco; Crandall, Wallace; Doarn, Charles; Heyman, Melvin B; Keljo, David; Denson, Lee A
2015-07-01
Medication nonadherence is a significant health care issue requiring regular behavioral treatment. Lack of sufficient health care resources and patient/family time commitment for weekly treatment are primary barriers to receiving appropriate self-management support. We describe the methodology of the Telehealth Enhancement of Adherence to Medication (TEAM) trial for medication nonadherence in pediatric inflammatory bowel disease (IBD). For this trial, participants 11-18 years of age will be recruited from seven pediatric hospitals and will complete an initial 4-week run in to assess adherence to a daily medication. Those who take less than 90% of their prescribed medication will be randomized. A total of 194 patients with IBD will be randomized to either a telehealth behavioral treatment (TBT) arm or education only (EO) arm. All treatments will be delivered via telehealth video conferencing. The patients will be assessed at baseline, post-treatment, 3, 6, and 12 months. We anticipate that participants in the TBT arm will demonstrate a statistically significant improvement at post-treatment and 3-, 6-, and 12-month follow-up compared to participants in the EO arm for both medication adherence and secondary outcomes (i.e., disease severity, patient quality of life, and health care utilization). If efficacious, the TEAM intervention could be disseminated broadly and reduce health care access barriers so that the patients could receive much needed self-management intervention. Copyright © 2015 Elsevier Inc. All rights reserved.
Design and testing of a functional arm orthosis in patients with neuromuscular diseases.
Rahman, Tariq; Sample, Whitney; Seliktar, Rahamim; Scavina, Mena T; Clark, Alisa L; Moran, Kacy; Alexander, Michael A
2007-06-01
The objective of this study was to determine the utility of a passive gravity-balanced arm orthosis, the Wilmington robotic exoskeleton (WREX), for patients with neuromuscular diseases. The WREX, a four-degrees-of-freedom functional orthosis, is energized by rubber bands to eliminate gravity and is attached to the wheelchair. The development and clinical testing of WREX is described in this report. Seventeen patients (14 boys and 3 girls) with muscular disabilities participated in the study. Ages ranged from 4 to 20 years. Criteria for inclusion included a weakened arm, use of a wheelchair, the ability to grasp and release objects, and the ability to provide feedback on device use. Testing consisted of administering the Jebsen test of hand function without WREX and then testing again after approximately two weeks of wearing the WREX orthosis. The timed results of each task within the test then were compared. Specific tasks related to vertical movement required less time to perform with the WREX. A large number of subjects were able to perform the Jebsen tasks with the WREX, where they were unable to perform the task without the WREX. Patients can benefit from WREX because it increases their performance in daily living activities and makes many tasks possible. The range-of-motion in the patients' arms increased considerably, while the time required to complete some of the Jebsen test tasks decreased. Most patients were very receptive to WREX, although a few were ambivalent.
Detection of the spatial accuracy of an O-arm in the region of surgical interest
NASA Astrophysics Data System (ADS)
Koivukangas, Tapani; Katisko, Jani P. A.; Koivukangsa, John P.
2013-03-01
Medical imaging is an essential component of a wide range of surgical procedures1. For image guided surgical (IGS) procedures, medical images are the main source of information2. The IGS procedures rely largely on obtained image data, so the data needs to provide differentiation between normal and abnormal tissues, especially when other surgical guidance devices are used in the procedures. The image data also needs to provide accurate spatial representation of the patient3. This research has concentrated on the concept of accuracy assessment of IGS devices to meet the needs of quality assurance in the hospital environment. For this purpose, two precision engineered accuracy assessment phantoms have been developed as advanced materials and methods for the community. The phantoms were designed to mimic the volume of a human head as the common region of surgical interest (ROSI). This paper introduces the utilization of the phantoms in spatial accuracy assessment of a commercial surgical 3D CT scanner, the O-Arm. The study presents methods and results of image quality detection of possible geometrical distortions in the region of surgical interest. The results show that in the pre-determined ROSI there are clear image distortion and artefacts using too high imaging parameters when scanning the objects. On the other hand, when using optimal parameters, the O-Arm causes minimal error in IGS accuracy. The detected spatial inaccuracy of the O-Arm with used parameters was in the range of less than 1.00 mm.
Hegge, Ann Magdalen; Bucher, Elias; Ettema, Gertjan; Faude, Oliver; Holmberg, Hans-Christer; Sandbakk, Øyvind
2016-02-01
To characterize gender differences in power output, energetic capacity and exercise efficiency during whole-body (WP), upper-body (UP), and arm poling (AP). Ten male and ten female elite cross-country skiers, matched for international performance level, completed three incremental submaximal tests and a 3-min self-paced performance test on a Concept2 SkiErg. Power output, cardiorespiratory and kinematic variables were monitored. Body composition was determined by dual-energy X-ray absorptiometry. The men demonstrated 87, 97 and 103% higher power output, and 51, 65 and 71% higher VO2peak (L min(−1)) than the women during WP, UP and AP, respectively, while utilizing ~10% more of their running VO2max in all modes (all P < 0.001). The men had 35, 38 and 59% more lean mass in the whole body, upper body and arms (all P < 0.001). The men exhibited greater shoulder and elbow extension at the start of poling and greater trunk flexion at the end of poling (all P < 0.05). The relationship between VO2 and power output did not differ between the men and women. Gender differences in power production and peak aerobic capacity increased sequentially from WP to UP to AP, coinciding with a greater portion of the muscle mass in the arms of the men. Although the men and women employed each poling technique differently, the estimated efficiency of double poling was independent of gender.
Adepoju, Omolola E; Bolin, Jane N; Phillips, Charles D; Zhao, Hongwei; Ohsfeldt, Robert L; McMaughan, Darcy K; Helduser, Janet W; Forjuoh, Samuel N
2014-04-01
This study compared time-to-hospitalization among subjects enrolled in different diabetes self-management programs (DSMP). We sought to determine whether the interventions delayed the occurrence of any acute event necessitating hospitalization. Electronic medical records (EMR) were obtained for 376 adults enrolled in a randomized controlled trial (RCT) of Type 2 diabetes (T2DM) self-management programs. All study participants had uncontrolled diabetes and were randomized into either: personal digital assistant (PDA), Chronic Disease Self-Management Program (CDSMP), combined PDA and CDSMP (COM), or usual care (UC) groups. Subjects were followed for a maximum of two years. Time-to-hospitalization was measured as the interval between study enrollment and the occurrence of a diabetes-related hospitalization. Subjects enrolled in the CDSMP-only arm had significantly prolonged time-to-hospitalization (Hazard ratio: 0.10; p=0.002) when compared to subjects in the control arm. Subjects in the PDA-only and combined PDA and CDSMP arms showed no improvements in comparison to the control arm. CDSMP can be effective in delaying time-to-hospitalization among patients with T2DM. Reducing unnecessary healthcare utilization, particularly inpatient hospitalization is a key strategy to improving the quality of health care and lowering associated health care costs. The CDSMP offers the potential to reduce time-to-hospitalization among T2DM patients. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Weatherholt, Alyssa M; Warden, Stuart J
2018-06-01
To explore throwing athletes as a prospective, within-subject controlled model for studying the response of the skeleton to exercise. Male pre-pubertal throwing athletes (n=12; age=10.3±0.6 yrs) had distal humerus cortical volumetric bone mineral density (Ct.vBMD), cortical bone mineral content (Ct.BMC), total area (Tt.Ar), cortical area (Ct.Ar), medullary area (Me.Ar), cortical thickness (Ct.Th) and polar moment of inertia (IP) assessed within their throwing (exercised) and nonthrowing (control) arms by peripheral quantitative computed tomography at baseline and 12 months. Throwing-to-nonthrowing arm percent differences (i.e. bilateral asymmetry) were compared over time. Over 12 months, the throwing arm gained 4.3% (95% Cl=1.1% to 7.5%), 2.9% (95% Cl=0.3% to 5.4%), 3.9% (95% Cl=0.7% to 7.0%), and 8.2% (95% Cl=2.0% to 6.8%) more Ct.BMC, Ct.Ar, Tt.Ar, and I P than the nonthrowing arm, respectively (all p<0.05). There was no significant effect of throwing on Ct.vBMD, Ct.Th and Me.Ar (all p=0.18-0.82). Throwing induced surface-specific cortical bone adaptation at the distal humeral diaphysis that contributed to a gain in estimated strength. These longitudinal pilot data support the utility of throwing athletes as a within-subject controlled model to explore factors influencing exercise-induced bone adaptation during the critical growing years.
Cambon, Jesse; Cordier, Tristan; Munnich, Elizabeth L.; Renda, Andrew; Kapur, Bobby; Hoxhaj, Shkelzen; Williams, Meredith
2018-01-01
Background The impact of messaging campaigns on influencing urgent care– and emergent care–seeking behaviors, including the use of in-network providers, is not well-understood. Although out-of-network healthcare utilization can have negative financial consequences for patients in narrow network Affordable Care Act plans, individuals with time-sensitive medical conditions, and especially patients visiting the emergency department, may not think about out-of-network issues. Inappropriate or avoidable emergency department visits can also create unnecessary costs for patients. Objective To evaluate the impact of 5 messaging strategies to educate individuals about the use of in-network providers and when care should be sought in the emergency department, urgent care center, or other sites of care. Methods Using a retrospective analysis, individuals aged ≥18 years who were enrolled in an individually purchased Affordable Care Act–compliant Humana plan as of July 1, 2015, were randomized to 1 of 5 messaging arms (e-mail, magnet mailer with or without e-mail, and key-tag mailer with or without e-mail) or to a control group. The outreach was implemented and evaluated in 2 distinct, geographically defined populations of Orlando, Palm Beach, and Tampa, Florida (Population 1); and Atlanta, Georgia, and San Antonio and Austin, Texas (Population 2). The relative number of each emergency department, urgent care, and out-of-network visits during follow-up was modeled using negative binomial regression. Cox proportional hazard models were used to calculate the risk for ≥1 of each visit type (assessed separately) and high emergency department utilization (defined as ≥3 visits during follow-up) relative to the control, while accounting for variable follow-up time. Results The relative numbers of each visit type assessed were not significantly different for any message group compared with the control in either population. The risk for an emergency department visit was 4% lower in the e-mail arm of Population 2 (hazard ratio [HR], 0.96; 95% confidence interval [CI], 0.94–0.99; P = .005) and 7% lower in the e-mail/key-tag arm of Population 1 (HR, 0.93; 95% CI, 0.89–0.97; P = .001). The risk for high emergency department utilization was significantly reduced by the key-tag, magnet, and e-mail/key-tag strategies in Population 1, but no impact was found in Population 2. Conclusion Despite the mixed results, the study provides new insights into how different messaging strategies could be used to educate patients and influence healthcare utilization decisions by people with health insurance. PMID:29915641
Naturally stable Sagnac–Michelson nonlinear interferometer
Lukens, Joseph M.; Peters, Nicholas A.; Pooser, Raphael C.
2016-11-16
Interferometers measure a wide variety of dynamic processes by converting a phase change into an intensity change. Nonlinear interferometers, making use of nonlinear media in lieu of beamsplitters, promise substantial improvement in the quest to reach the ultimate sensitivity limits. Here we demonstrate a new nonlinear interferometer utilizing a single parametric amplifier for mode mixing conceptually, a nonlinear version of the conventional Michelson interferometer with its arms collapsed together. We observe up to 99.9% interference visibility and find evidence for noise reduction based on phase-sensitive gain. As a result, our configuration utilizes fewer components than previous demonstrations and requires nomore » active stabilization, offering new capabilities for practical nonlinear interferometric-based sensors.« less
Jeffs, Eunice; Ream, Emma; Taylor, Cath; Bick, Debra
2018-01-01
ABSTRACT Objective: To identify the effect of decongestive lymphedema treatment on excess arm volume or patient-centered outcomes in women presenting within either 12 months or a mean nine months of developing arm lymphedema following breast cancer treatment. Introduction: Lymphedema is a common consequence of breast cancer treatment requiring life-long treatment to reduce symptoms and prevent complications. Currently, evidence to inform the optimal decongestive lymphedema treatment package is lacking. Inclusion criteria: The review included studies on women who received lymphedema treatment within either 12 months or a mean of nine months of developing unilateral breast cancer-related arm lymphedema. The intervention was any decongestive lymphedema treatment delivered with the purpose of reducing arm lymphedema, compared to another form of lymphedema treatment (whether self or practitioner-administered), placebo or no treatment. The clinical outcome was excess arm volume; patient-centered outcomes were health-related quality of life, arm heaviness, arm function, patient-perceived benefit and satisfaction with treatment. Experimental study designs were eligible, including randomized and non-randomized controlled trials, quasi-experimental, prospective and retrospective before and after studies were considered. Methods: A three-step search strategy was utilized to find published and unpublished studies. The search identified studies published from the inception of each database to July 6, 2016. Reference lists were scanned to identify further eligible studies. Studies were critically appraised using appropriate standardized critical appraisal instruments from the Joanna Briggs Institute. Details describing each study and treatment results regarding outcomes of interest were extracted from papers included in the review using appropriate standardized data extraction tools from the Joanna Briggs Institute. Due to heterogeneity in included studies, results for similar outcome measures were not pooled in statistical meta-analysis. A narrative and tabular format was used to synthesize results from identified and included studies. Results: Seven studies reporting results for outcomes of interest were critically appraised and included in the review: five randomized controlled trials and two descriptive (uncontrolled) studies. Reported outcomes included excess arm volume (five studies), health-related quality of life (three studies), arm heaviness (one study), arm function (two studies) and patient-perceived benefit (two studies). There was some evidence that decongestive treatments were effective for women presenting within either 12 months or a mean of nine months of developing breast cancer-related arm lymphedema, but the wide range of data prevented comparison of treatment findings which limited our ability to answer the review questions. Conclusions: Weak evidence (grade B) for the impact of decongestive lymphedema treatment on women with early lymphedema (i.e. less than 12 months duration of BCRL symptoms) did not allow any conclusions to be drawn about the most effective treatment to be offered when these women first present for treatment. Findings provided no justification to support change to current practice. Future primary research needs to focus on the most effective treatment for women when they first present with lymphedema symptoms, e.g. treatment provided within 12 months of developing symptoms. Studies should be adequately powered and recruit women exclusively with less than 12 months duration of breast cancer-related lymphedema symptoms, provide longer follow-up to monitor treatment effect over time, with comparable treatment protocols, outcome measures and reporting methods. PMID:29419623
Physics and technology of the arms race
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garwin, R.L.
1983-01-01
Traditional military concepts of superiority and effectiveness (as embodied in Lanchester's law) have little relevance to thermonuclear weapons, with their enormous effectiveness in destruction of society. Few are needed to saturate their deterrent effect, but their military effectiveness is limited. The evolution and future of strategic nuclear forces is discussed, and their declining marginal utility emphasized. Some calculations relevant to the nuclear confrontation are presented (Lanchester's Law; skin effect of VLF and ELF signals to submarines; the rocket equation; simple radar-range equation) and recommendations presented for future strategic forces and arms control initiatives. Recommended programs include a silo-based 12-ton single-warheadmore » missile (SICM), the development of buried-bomb defense of individual Minuteman silos, the completion of the deployment of air-launched cruise missiles on the B-52 fleet, and the development of small (1000-ton) submarines for basing ICBM-range missiles.« less
Systematic drug repositioning through mining adverse event data in ClinicalTrials.gov.
Su, Eric Wen; Sanger, Todd M
2017-01-01
Drug repositioning (i.e., drug repurposing) is the process of discovering new uses for marketed drugs. Historically, such discoveries were serendipitous. However, the rapid growth in electronic clinical data and text mining tools makes it feasible to systematically identify drugs with the potential to be repurposed. Described here is a novel method of drug repositioning by mining ClinicalTrials.gov. The text mining tools I2E (Linguamatics) and PolyAnalyst (Megaputer) were utilized. An I2E query extracts "Serious Adverse Events" (SAE) data from randomized trials in ClinicalTrials.gov. Through a statistical algorithm, a PolyAnalyst workflow ranks the drugs where the treatment arm has fewer predefined SAEs than the control arm, indicating that potentially the drug is reducing the level of SAE. Hypotheses could then be generated for the new use of these drugs based on the predefined SAE that is indicative of disease (for example, cancer).
1980-12-01
underrepresentation . As one can see from Figure 2-4, the greatest density of women is in traditional skills, the medical/dental and administrat- ion... Industrial Elec Motors/Generators Electric Wiring Food Service Gas Engine Repair General Merch Sales Graphic Arts Hotel & Motel Mgt Masonry Office...Small Engine Repair (marine ment of Vocational and industrial ) Education Welding Truck Driving Simulator Connecticut State Depart- Training ment of
Radio-Frequency Down-Conversion via Sampled Analog Optical Links
2010-08-09
temporal intensity Popt(ω) includes intensity noise quantities arising from the optical source (e.g. laser intensity noise, amplified spontaneous emission...nm distributed feedback laser RF Down-Conversion via Sampled Links 5 (DFB, EM4, Inc.) the output of which is modulated via a low-biased Mach-Zehnder...Figure 5 (a). For comparison purposes the RF gain of one arm of the balanced link (utilizing a continuous- wave laser source) is measured and
Nursing gaze of the Eastern Front in World War II: a feminist narrative analysis.
Georges, Jane M; Benedict, Susan
2008-01-01
Grounded in a feminist perspective, a narrative analysis of letters written by Martha Lohmann, a nurse who served with the German Army on the Eastern Front in World War II, is undertaken. Utilizing "gaze" as a focus, an exploration of the narrative and the multiple gazes embedded within it is performed. Implications for future analysis of nurses' textual accounts of violence, armed conflict, and war are presented.
Nations Hospitable to Organized Crime and Terrorism
2003-10-01
illegal migrants from Somalia, Ethiopia, China, India, and Sri Lanka pass through the airport’s weak customs barriers en route to Western Europe and...osmium-187, possibly en route to terrorist organizations or Iraq. In December 2001, Moscow authorities arrested a group of Chechens from Kazakhstan...utilizes the city as a transit point en route to Sri Lanka.492 The LTTE continues to procure arms from arsenals abandoned after Cambodia’s civil war
Branding Icarus: The Construction of Identity and Diversity at The United States Air Force Academy
2015-06-01
Government-sponsored research , prompting the question: “Why study the military if the result of investigations can be utilized by armed forces to...Gradu- ates (Colorado Springs, CO: HQ USAFA Institutional Research and Assessment Division, 2005), 71 social studies .11 There are also gaps...PRESENTED TO THE FACULTY OF THE SCHOOL OF ADVANCED AIR AND SPACE STUDIES FOR COMPLETION OF GRADUATION REQUIREMENTS SCHOOL OF ADVANCED AIR AND
Kuo, Ching-Ying; Li, Xu; Kong, Xiang-Qian; Luo, Cheng; Chang, Che-Chang; Chung, Yiyin; Shih, Hsiu-Ming; Li, Keqin Kathy; Ann, David K
2014-07-25
Krüppel-associated box domain-associated protein 1 (KAP1) is a universal transcriptional corepressor that undergoes multiple posttranslational modifications (PTMs), including SUMOylation and Ser-824 phosphorylation. However, the functional interplay of KAP1 PTMs in regulating KAP1 turnover during DNA damage response remains unclear. To decipher the role and cross-talk of multiple KAP1 PTMs, we show here that DNA double strand break-induced KAP1 Ser-824 phosphorylation promoted the recruitment of small ubiquitin-like modifier (SUMO)-targeted ubiquitin E3 ligase, ring finger protein 4 (RNF4), and subsequent RNF4-mediated, SUMO-dependent degradation. Besides the SUMO interacting motif (SIM), a previously unrecognized, but evolutionarily conserved, arginine-rich motif (ARM) in RNF4 acts as a novel recognition motif for selective target recruitment. Results from combined mutagenesis and computational modeling studies suggest that RNF4 utilizes concerted bimodular recognition, namely SIM for Lys-676 SUMOylation and ARM for Ser(P)-824 of simultaneously phosphorylated and SUMOylated KAP1 (Ser(P)-824-SUMO-KAP1). Furthermore, we proved that arginines 73 and 74 within the ARM of RNF4 are required for efficient recruitment to KAP1 or accelerated degradation of promyelocytic leukemia protein (PML) under stress. In parallel, results of bimolecular fluorescence complementation assays validated the role of the ARM in recognizing Ser(P)-824 in living cells. Taken together, we establish that the ARM is required for RNF4 to efficiently target Ser(P)-824-SUMO-KAP1, conferring ubiquitin Lys-48-mediated proteasomal degradation in the context of double strand breaks. The conservation of such a motif may possibly explain the requirement for timely substrate selectivity determination among a myriad of SUMOylated proteins under stress conditions. Thus, the ARM dynamically regulates the SIM-dependent recruitment of targets to RNF4, which could be critical to dynamically fine-tune the abundance of Ser(P)-824-SUMO-KAP1 and, potentially, other SUMOylated proteins during DNA damage response. © 2014 by The American Society for Biochemistry and Molecular Biology, Inc.
Kuo, Ching-Ying; Li, Xu; Kong, Xiang-Qian; Luo, Cheng; Chang, Che-Chang; Chung, Yiyin; Shih, Hsiu-Ming; Li, Keqin Kathy; Ann, David K.
2014-01-01
Krüppel-associated box domain-associated protein 1 (KAP1) is a universal transcriptional corepressor that undergoes multiple posttranslational modifications (PTMs), including SUMOylation and Ser-824 phosphorylation. However, the functional interplay of KAP1 PTMs in regulating KAP1 turnover during DNA damage response remains unclear. To decipher the role and cross-talk of multiple KAP1 PTMs, we show here that DNA double strand break-induced KAP1 Ser-824 phosphorylation promoted the recruitment of small ubiquitin-like modifier (SUMO)-targeted ubiquitin E3 ligase, ring finger protein 4 (RNF4), and subsequent RNF4-mediated, SUMO-dependent degradation. Besides the SUMO interacting motif (SIM), a previously unrecognized, but evolutionarily conserved, arginine-rich motif (ARM) in RNF4 acts as a novel recognition motif for selective target recruitment. Results from combined mutagenesis and computational modeling studies suggest that RNF4 utilizes concerted bimodular recognition, namely SIM for Lys-676 SUMOylation and ARM for Ser(P)-824 of simultaneously phosphorylated and SUMOylated KAP1 (Ser(P)-824-SUMO-KAP1). Furthermore, we proved that arginines 73 and 74 within the ARM of RNF4 are required for efficient recruitment to KAP1 or accelerated degradation of promyelocytic leukemia protein (PML) under stress. In parallel, results of bimolecular fluorescence complementation assays validated the role of the ARM in recognizing Ser(P)-824 in living cells. Taken together, we establish that the ARM is required for RNF4 to efficiently target Ser(P)-824-SUMO-KAP1, conferring ubiquitin Lys-48-mediated proteasomal degradation in the context of double strand breaks. The conservation of such a motif may possibly explain the requirement for timely substrate selectivity determination among a myriad of SUMOylated proteins under stress conditions. Thus, the ARM dynamically regulates the SIM-dependent recruitment of targets to RNF4, which could be critical to dynamically fine-tune the abundance of Ser(P)-824-SUMO-KAP1 and, potentially, other SUMOylated proteins during DNA damage response. PMID:24907272
Deribew, Amare; Birhanu, Zewdie; Sena, Lelisa; Dejene, Tariku; Reda, Ayalu A; Sudhakar, Morankar; Alemseged, Fessehaye; Tessema, Fasil; Zeynudin, Ahmed; Biadgilign, Sibhatu; Deribe, Kebede
2012-01-06
Long-lasting insecticide-treated bed nets (LLITN) have demonstrated a significant effect in reducing malaria-related morbidity and mortality. However, barriers on the utilization of LLITN have hampered the desired outcomes. The aim of this study was to assess the effect of community empowerment on the burden of malaria and anaemia in under-five children in Ethiopia. A cluster randomized trial was done in 22 (11 intervention and 11 control) villages in south-west Ethiopia. The intervention consisted of tailored training of household heads about the proper use of LLITN and community network system. The burden of malaria and anaemia in under-five children was determined through mass blood investigation at baseline, six and 12 months of the project period. Cases of malaria and anaemia were treated based on the national protocol. The burden of malaria and anaemia between the intervention and control villages was compared using the complex logistic regression model by taking into account the clustering effect. Eight Focus group discussions were conducted to complement the quantitative findings. A total of 2,105 household heads received the intervention and the prevalence of malaria and anaemia was assessed among 2410, 2037 and 2612 under-five children at baseline, six and 12 months of the project period respectively. During the high transmission/epidemic season, children in the intervention arm were less likely to have malaria as compared to children in the control arm (OR = 0.42; 95%CI: 0.32, 0.57). Symptomatic malaria also steadily declined in the intervention villages compared to the control villages in the follow up periods. Children in the intervention arm were less likely to be anaemic compared to those in the control arm both at the high (OR = 0.84; 95%CI: 0.71, 0.99)) and low (OR = 0.73; 95%CI: 0.60, 0.89) transmission seasons. Training of household heads on the utilization of LLITN significantly reduces the burden of malaria in under-five children. The Ministry of Health of Ethiopia in collaboration with other partners should design similar strategies in high-risk areas to control malaria in Ethiopia. Australia and New Zealand Clinical Trials Register (ANZCTR): ACTRN12610000035022.
Comparison of two plethysmography systems in assessment of forearm blood flow.
Leslie, Stephen J; Attinà, Teresa; Hultsch, Ellen; Bolscher, Luc; Grossman, Matthias; Denvir, Martin A; Webb, David J
2004-05-01
Venous occlusion plethysmography is widely used to assess forearm blood flow (FBF). We compared the established Hokanson system (HEC4) with a newly developed Filtrass 2001 system (F2001). The HEC4 uses mercury-in-Silastic strain gauges, whereas F2001 detects volume changes with a nonmercury linear displacement device. The aim of this study was to evaluate the new F2001 against the HEC4 in terms of repeatability and systematic bias. Ten subjects were studied on 4 separate days in random order using either the HEC4 on both arms, the F2001 on both arms, the HEC4 on the right arm with the F2001 on the left, or the F2001 on the right arm and the HEC4 on the left. Stroop's colored word conflict test and postocclusive hyperemia were used to increase FBF, and lower body negative pressure was used to lower FBF. Stroop's colored word conflict test and lower body negative pressure increased (24.6 +/- 1.5%, n = 240, P < 0.0001) and decreased (18.7 +/- 0.8%, n = 240, P < 0.0001) FBF, respectively. Postocclusive hyperemia after occlusion times of 5, 8, and 13 min substantially increased FBF by 390 +/- 86, 756 +/- 217, and 851 +/- 132%, respectively. Repeatability was not different between the devices (0.10 +/- 2.37 vs. -0.47 +/- 1.92 l/min, n = 125, P > 0.05), and there was no systematic bias. The F2001 is a newly developed plethysmography system that does not utilize mercury and is suitable for assessing changes of FBF in physiological studies.
NASA Astrophysics Data System (ADS)
Kainerstorfer, Jana M.; Amyot, Franck; Demos, Stavros G.; Hassan, Moinuddin; Chernomordik, Victor; Hitzenberger, Christoph K.; Gandjbakhche, Amir H.; Riley, Jason D.
2009-07-01
Quantitative assessment of skin chromophores in a non-invasive fashion is often desirable. Especially pixel wise assessment of blood volume and blood oxygenation is beneficial for improved diagnostics. We utilized a multi-spectral imaging system for acquiring diffuse reflectance images of healthy volunteers' lower forearm. Ischemia and reactive hyperemia was introduced by occluding the upper arm with a pressure cuff for 5min with 180mmHg. Multi-spectral images were taken every 30s, before, during and after occlusion. Image reconstruction for blood volume and blood oxygenation was performed, using a two layered skin model. As the images were taken in a non-contact way, strong artifacts related to the shape (curvature) of the arms were observed, making reconstruction of optical / physiological parameters highly inaccurate. We developed a curvature correction method, which is based on extracting the curvature directly from the intensity images acquired and does not require any additional measures on the object imaged. The effectiveness of the algorithm was demonstrated, on reconstruction results of blood volume and blood oxygenation for in vivo data during occlusion of the arm. Pixel wise assessment of blood volume and blood oxygenation was made possible over the entire image area and comparison of occlusion effects between veins and surrounding skin was performed. Induced ischemia during occlusion and reactive hyperemia afterwards was observed and quantitatively assessed. Furthermore, the influence of epidermal thickness on reconstruction results was evaluated and the exact knowledge of this parameter for fully quantitative assessment was pointed out.
NASA Astrophysics Data System (ADS)
Zhang, Haichong K.; Aalamifar, Fereshteh; Boctor, Emad M.
2016-04-01
Synthetic aperture for ultrasound is a technique utilizing a wide aperture in both transmit and receive to enhance the ultrasound image quality. The limitation of synthetic aperture is the maximum available aperture size limit determined by the physical size of ultrasound probe. We propose Synthetic-Tracked Aperture Ultrasound (STRATUS) imaging system to overcome the limitation by extending the beamforming aperture size through ultrasound probe tracking. With a setup involving a robotic arm, the ultrasound probe is moved using the robotic arm, while the positions on a scanning trajectory are tracked in real-time. Data from each pose are synthesized to construct a high resolution image. In previous studies, we have demonstrated the feasibility through phantom experiments. However, various additional factors such as real-time data collection or motion artifacts should be taken into account when the in vivo target becomes the subject. In this work, we build a robot-based STRATUS imaging system with continuous data collection capability considering the practical implementation. A curvilinear array is used instead of a linear array to benefit from its wider capture angle. We scanned human forearms under two scenarios: one submerged the arm in the water tank under 10 cm depth, and the other directly scanned the arm from the surface. The image contrast improved 5.51 dB, and 9.96 dB for the underwater scan and the direct scan, respectively. The result indicates the practical feasibility of STRATUS imaging system, and the technique can be potentially applied to the wide range of human body.
Borisenko, Oleg; Haude, Michael; Hoppe, Uta C; Siminiak, Tomasz; Lipiecki, Janusz; Goldberg, Steve L; Mehta, Nawzer; Bouknight, Omari V; Bjessmo, Staffan; Reuter, David G
2015-05-14
To determine the cost-effectiveness of the percutaneous mitral valve repair (PMVR) using Carillon® Mitral Contour System® (Cardiac Dimensions Inc., Kirkland, WA, USA) in patients with congestive heart failure accompanied by moderate to severe functional mitral regurgitation (FMR) compared to the prolongation of optimal medical treatment (OMT). Cost-utility analysis using a combination of a decision tree and Markov process was performed. The clinical effectiveness was determined based on the results of the Transcatheter Implantation of Carillon Mitral Annuloplasty Device (TITAN) trial. The mean age of the target population was 62 years, 77% of the patients were males, 64% of the patients had severe FMR and all patients had New York Heart Association functional class III. The epidemiological, cost and utility data were derived from the literature. The analysis was performed from the German statutory health insurance perspective over 10-year time horizon. Over 10 years, the total cost was €36,785 in the PMVR arm and €18,944 in the OMT arm. However, PMVR provided additional benefits to patients with an 1.15 incremental quality-adjusted life years (QALY) and an 1.41 incremental life years. The percutaneous procedure was cost-effective in comparison to OMT with an incremental cost-effectiveness ratio of €15,533/QALY. Results were robust in the deterministic sensitivity analysis. In the probabilistic sensitivity analysis with a willingness-to-pay threshold of €35,000/QALY, PMVR had a 84 % probability of being cost-effective. Percutaneous mitral valve repair may be cost-effective in inoperable patients with FMR due to heart failure.
Waschke, Albrecht; Arefian, Habibollah; Walter, Jan; Hartmann, Michael; Maschmann, Jens; Kalff, Rolf
2018-06-01
Concomitant radiochemotherapy followed by six cycles of temozolomide (= short term) is considered as standard therapy for adults with newly diagnosed glioblastoma. In contrast, open-end administration of temozolomide until progression (= long-term) is proposed by some authors as a viable alternative. We aimed to determine the cost-effectiveness of long-term temozolomide therapy for patients newly diagnosed with glioblastoma compared to standard therapy. A Markov model was constructed to compare medical costs and clinical outcomes for both therapy types over a time horizon of 60 months. Transition probabilities for standard therapy were calculated from randomized controlled trial data by Stupp et al. The data for long-term temozolomide therapy was collected by matching a cohort treated in the Department of Neurosurgery at Jena University Hospital. Health utilities were obtained from a previous cost utility study. The cost perspective was based on health insurance. The base case analysis showed a median overall survival of 17.1 months and a median progression-free survival of 7.4 months for patients in the long-term temozolomide therapy arm. The cost-effectiveness analysis using all base case parameters in a time-dependent Markov model resulted in an incremental effectiveness of 0.022 quality-adjusted life-years (QALYs). The incremental cost-effectiveness ratio (ICER) was €351,909/QALY. Sensitivity analyses showed that parameters with the most influence on ICER were the health state utility of progression in both therapy arms. Although open-ended temozolomide therapy is very expensive, the ICER of this therapy is comparable to that of the standard temozolomide therapy for patients newly diagnosed with glioblastoma.
NASA Technical Reports Server (NTRS)
Robinson, W. W.
1987-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the Electrical Power Distribution and Control (EPD and C)/Remote Manipulator System (RMS) hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained in the NASA FMEA/CIL documentation. This report documents the results of the independent analysis of the EPD and C/RMS (both port and starboard) hardware. The EPD and C/RMS subsystem hardware provides the electrical power and power control circuitry required to safely deploy, operate, control, and stow or guillotine and jettison two (one port and one starboard) RMSs. The EPD and C/RMS subsystem is subdivided into the four following functional divisions: Remote Manipulator Arm; Manipulator Deploy Control; Manipulator Latch Control; Manipulator Arm Shoulder Jettison; and Retention Arm Jettison. The IOA analysis process utilized available EPD and C/RMS hardware drawings and schematics for defining hardware assemblies, components, and hardware items. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based on the severity of the effect for each failure mode.
Predicting the safe load on backpacker's arm using Lagrange multipliers method
NASA Astrophysics Data System (ADS)
Abdalla, Faisal Saleh; Rambely, Azmin Sham
2014-09-01
In this study, a technique has been suggested to reduce a backpack load by transmitting determined loads to the children arm. The purpose of this paper is to estimate school children arm muscles while load carriage as well as to determine the safe load can be carried at wrist while walking with backpack. A mathematical model, as three DOFs model, was investigated in the sagittal plane and Lagrange multipliers method (LMM) was utilized to minimize a quadratic objective function of muscle forces. The muscle forces were minimized with three different load conditions which are termed as 0-L=0 N, 1-L=21.95 N, and 2-L=43.9 N. The investigated muscles were estimated and compared to their maximum forces throughout the load conditions. Flexor and extensor muscles were estimated and the results showed that flexor muscles were active while extensor muscles showed inactivity. The estimated muscle forces were didn't exceed their maximum forces with 0-L and 1-L conditions whereas biceps and FCR muscles exceeded their maximum forces with 2-L condition. Consequently, 1-L condition is quiet safe to be carried by hand whereas 2-L condition is not. Thus to reduce the load in the backpack the transmitted load shouldn't exceed 1-L condition.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lowden, R.; Kelly, R.
1997-05-30
The purpose of the Cooperative Research and Development Agreement (CRADA) between Martin Marietta Energy Systems, Inc., and Delta Frangible Ammunition (DFA), was to identify and evaluate composite materials for the development of small arms ammunition. Currently available small arms ammunition utilizes lead as the major component of the projectile. The introduction of lead into the environment by these projectiles when they are expended is a rapidly increasing environmental problem. At certain levels, lead is a toxic metal to the environment and a continual health and safety concern for firearm users as well as those who must conduct lead recovery operationsmore » from the environment. DFA is a leading supplier of high-density mixtures, which will be used to replace lead-based ammunition in specific applications. Current non-lead ammunition has several limitations that prevent it from replacing lead-based ammunition in many applications (such as applications that require ballistics, weapon recoil, and weapon function identical to that of lead-based ammunition). The purpose of the CRADA was to perform the research and development to identify cost-effective materials to be used in small arms ammunition that eventually will be used in commercially viable, environmentally conscious, non-lead, frangible and/or non-frangible, ammunition.« less
Nandan, R; Nanda, K K
2017-08-31
Geometrical tunability offers sharp edges and an open-armed structure accompanied with a high electrochemical active surface area to ensure the efficient and effective utilization of materials by exposing the electrochemical active sites for facile accessibility of reactant species. Herein, we report a one-step, single-pot, surfactant-free, electroless, and economic route to synthesize palladium sulfide nanostructures with different geometries at mild temperatures and their catalytic properties towards the oxygen reduction reaction (ORR) and methanol electro-oxidation (MOR). For ORR, the positive on-set, half wave potentials, smaller Tafel slope, high electrochemical active surface area, large roughness factor, and better cyclic stability of the proposed nanostructures as compared to those of the commercial state-of-the-art Pt-C/PdS catalysts suggest their superiority in an alkaline medium. In addition, high mass activity (J f ∼ 715 mA mg -1 ), in comparison with that of the commercial state-of-the-art Pt-C/PdS catalysts (J f ∼ 138/41 mA mg -1 , respectively), and high J f /J b (1.52) along with the superior operational stability of the multi-arm palladium sulfide nanostructures towards MOR advocates the bi-functional behavior of the catalyst and its potential as a promising Pt-free anode/cathode electrocatalyst in fuel cells.
NASA Astrophysics Data System (ADS)
Xu, Nuo; Lei, Xue; Yang, Xiaoli; Li, Xinhui; Ge, Zhenlin
2018-04-01
Objective: to compare canine tooth stress distribution condition during maxillary canine tooth distalization by different accessories of bracket-free invisible orthodontics technology after removal of maxillary first premolar, and provide basis for clinical design of invisible orthodontics technology. Method: CBCT scanning image of a patient with individual normal occlusion was adopted, Mimics, Geomagic and ProlE software were used for establishing three-dimensional models of maxilla, maxillary dentition, parodontium, invisible orthodontics appliance and accessories, ANSYS WORKBENCH was utilized as finite element analysis tools for analyzing stress distribution and movement pattern of canine tooth and parodontium when canine tooth was equipped with power arm and vertical rectangle accessory. Meanwhile, canine tooth none-accessory design group was regarded as a control. Result: teeth had even bistal surface stress distribution in the power arm group; stress was concentrated on distal tooth neck, and the stress was gradually deviated to mesial-labial side and distal lingual side in vertical rectangle group and none-accessory group. Conclusion: teeth tend to move as a whole in the Power arm group, vertical rectangle group has lower tooth gradient compared with the none-accessory group, teeth are inclined for movement in the none-accessory group, and canine teeth tend to rotate to the distal lingual side.
2002-05-30
KENNEDY SPACE CENTER, FLA. -- After rollback of the Rotating Service Structure in the early morning hours, Space Shuttle Endeavour sits bathed in light on its Mobile Launcher Platform on Launch Pad 39A. Seen extending to the cockpit area of Endeavour is the orbiter access arm. At the end of the arm is the White Room, an environmental chamber. Below, on either side of Endeavour's tail, are the tail service masts that support fluid, gas and electrical requirements of the orbiter's liquid oxygen and liquid hydrogen aft T-0 umbilicals. STS-111 is the second Utilization Flight to the International Space Station, carrying the Multi-Purpose Logistics Module Leonardo, the Mobile Base System (MBS), and a replacement wrist/roll joint for the Canadarm 2. Also onboard Space Shuttle Endeavour is the Expedition 5 crew who will replace Expedition 4 on board the Station. The MBS will be installed on the Mobile Transporter to complete the Canadian Mobile Servicing System, or MSS. The mechanical arm will then have the capability to "inchworm" from the U.S. Lab Destiny to the MSS and travel along the truss to work sites. Expedition 4 crew members will return to Earth with the STS-111 crew on Endeavour. Launch is scheduled for 7:44 p.m. EDT, May 30, 2002
Impact of Utilizing Photos and Deimos as Waypoints for Mars Human Surface Missions
NASA Technical Reports Server (NTRS)
Cianciolo, Alicia D.; Brown, Kendall
2015-01-01
Phobos and Deimos, the moons of Mars, are interesting exploration destinations that offer extensibility of the Asteroid Redirect Mission (ARM) technologies. Solar Electric Propulsion (SEP), asteroid rendezvous and docking, and surface operations can be used to land on and explore the moons of Mars. The close Mars vicinity of Phobos and Deimos warrant examining them as waypoints, or intermediate staging orbits, for Mars surface missions. This paper outlines the analysis performed to determine the mass impact of using the moons of Mars both as an intermediate staging point for exploration as well as for in-situ recourse utilization, namely propellant, to determine if the moons are viable options to include in the broader Mars surface exploration architecture.
Dual liquid and gas chromatograph system
Gay, D.D.
A chromatographic system is described that utilizes one detection system for gas chromatographic and micro-liquid chromatographic determinations. The detection system is a direct-current, atmospheric-pressure, helium plasma emission spectrometer. The detector utilizes a nontransparent plasma source unit which contains the plasma region and two side-arms which receive effluents from the micro-liquid chromatograph and the gas chromatograph. The dual nature of this chromatographic system offers: (1) extreme flexibility in the samples to be examined; (2) extreme low sensitivity; (3) element selectivity; (4) long-term stability; (5) direct correlation of data from the liquid and gas samples; (6) simpler operation than with individual liquid and gas chromatographs, each with different detection systems; and (7) cheaper than a commercial liquid chromatograph and a gas chromatograph.
Dual liquid and gas chromatograph system
Gay, Don D.
1985-01-01
A chromatographic system that utilizes one detection system for gas chromatographic and micro-liquid chromatographic determinations. The detection system is a direct-current, atmospheric-pressure, helium plasma emission spectrometer. The detector utilizes a non-transparent plasma source unit which contains the plasma region and two side-arms which receive effluents from the micro-liquid chromatograph and the gas chromatograph. The dual nature of this chromatographic system offers: (1) extreme flexibility in the samples to be examined; (2) extremely low sensitivity; (3) element selectivity; (4) long-term stability; (5) direct correlation of data from the liquid and gas samples; (6) simpler operation than with individual liquid and gas chromatographs, each with different detection systems; and (7) cheaper than a commercial liquid chromatograph and a gas chromatograph.
An Economic Analysis of United States Assistance to Selected Less Developed Countries.
1983-07-01
and peoples, upon request, assistance of such nature and in such amounts as the United States deems advisable and as may be effectively used by free...country has the capability to absorb and utilize the arms effectively . (11) What other military interests--for example, overflight rights or access to...expenditures has created the opposite effect . Internal stability has been sacrificed as a result of a defense build up. As an exampl,- -f lthrs phnnomnenon
1989-07-01
July 1989 Copyright @ 1989 Carnegie Mellon University ’Visiting Professor, Dpto Ingenieria Eldctrica, Electr6nica y Control, UNED, Ciudad Universitaria...signals typically utilized in existing industrial and research robots are parabolic trajectories of order at least two. This is because the desired...Discretos de Control Multivariables. Ph.D. Thesis, E.TS.I. Industriales of Universidad Politicnica of Madrid. September 1982. [14] Craig, J.J
Proprioceptive isokinetic exercise test
NASA Technical Reports Server (NTRS)
Dempster, P. T.; Bernauer, E. M.; Bond, M.; Greenleaf, J. E.
1993-01-01
Proprioception, the reception of stimuli within the body that indicates position, is an important mechanism for optimal human performance. People exposed to prolonged bed rest, microgravity, or other deconditioning situations usually experience reduced proprioceptor and kinesthetic stimuli that compromise body balance, posture, and equilibrium. A new proprioceptive test is described that utilizes the computer-driven LIDO isokinetic ergometer. An overview of the computer logic, software, and testing procedure for this proprioceptive test, which can be performed with the arms or legs, is described.
Cyber Defence in the Armed Forces of the Czech Republic
2010-11-01
undesirable action backward discovery. This solution is based on special tools using NetFlow protocol. Active network elements or specialized hardware...probes attached to the backbone network using a tap can be the sources of NetFlow data. The principal advantage of NetFlow protocol is the fact that it...provides primary data in the open form, which can be easily utilized in the subsequent operations. The FlowMon Probe 4000 is mostly used NetFlow
Effective utilization of gravity during arm downswing in keystrokes by expert pianists.
Furuya, S; Osu, R; Kinoshita, H
2009-12-01
The present study investigated a skill-level-dependent interaction between gravity and muscular force when striking piano keys. Kinetic analysis of the arm during the downswing motion performed by expert and novice piano players was made using an inverse dynamic technique. The corresponding activities of the elbow agonist and antagonist muscles were simultaneously recorded using electromyography (EMG). Muscular torque at the elbow joint was computed while excluding the effects of gravitational and motion-dependent interaction torques. During descending the forearm to strike the keys, the experts kept the activation of the triceps (movement agonist) muscle close to the resting level, and decreased anti-gravity activity of the biceps muscle across all loudness levels. This suggested that elbow extension torque was produced by gravity without the contribution of agonist muscular work. For the novices, on the other hand, a distinct activity in the triceps muscle appeared during the middle of the downswing, and its amount and duration were increased with increasing loudness. Therefore, for the novices, agonist muscular force was the predominant contributor to the acceleration of elbow extension during the downswing. We concluded that a balance shift from muscular force dependency to gravity dependency for the generation of a target joint torque occurs with long-term piano training. This shift would support the notion of non-muscular force utilization for improving physiological efficiency of limb movement with respect to the effective use of gravity.
Robotic lobectomy and segmentectomy for lung cancer: results and operating technique
2015-01-01
Video-assisted thoracic surgery (VATS) is a minimally invasive approach with several advantages over open thoracotomy for the surgery of lung cancer but also some limitations like rigid instruments and suboptimal vision. Robot technology is an evolution of manual videothoracoscopy introduced to overcome these limitations maintaining the advantages related to low invasiveness. More intuitive movements, greater flexibility and high definition three-dimensional vision are advantages of the robotic approach. Different studies demonstrate that robotic lobectomy and segmentectomy are feasible and safe with long term outcome similar to that of open/VATS approaches, however no randomised comparison are available and benefits in terms of quality of life (QOL) and pain need to be demonstrated yet. Several different robotic techniques are currently employed and differ for number of robotic arms (three versus four), the use of CO2 insufflation, timing of utility incision and the port positioning. The four arms robotic approach with anterior utility incision is the technique described by the authors. Indications to perform robotic lung resections may be more extensive than those of traditional videothoracoscpic approach and includes patients with locally advanced disease after chemotherapy or those requiring anatomical segmentectomy. Learning curve of vats and robotic lung resection is similar. High capital and running costs are the most important disadvantages. Entry of competitor companies should drive down costs. PMID:25984357
Lévesque, Renee; Marcelli, Daniele; Cardinal, Héloïse; Caron, Marie-Line; Grooteman, Muriel P C; Bots, Michiel L; Blankestijn, Peter J; Nubé, Menso J; Grassmann, Aileen; Canaud, Bernard; Gandjour, Afschin
2015-12-01
The aim of this study was to assess the cost effectiveness of high-efficiency on-line hemodiafiltration (OL-HDF) compared with low-flux hemodialysis (LF-HD) for patients with end-stage renal disease (ESRD) based on the Canadian (Centre Hospitalier de l'Université de Montréal) arm of a parallel-group randomized controlled trial (RCT), the CONvective TRAnsport STudy. An economic evaluation was conducted for the period of the RCT (74 months). In addition, a Markov state transition model was constructed to simulate costs and health benefits over lifetime. The primary outcome was costs per quality-adjusted life-year (QALY) gained. The analysis had the perspective of the Quebec public healthcare system. A total of 130 patients were randomly allocated to OL-HDF (n = 67) and LF-HD (n = 63). The cost-utility ratio of OL-HDF versus LF-HD was Can$53,270 per QALY gained over lifetime. This ratio was fairly robust in the sensitivity analysis. The cost-utility ratio was lower than that of LF-HD compared with no treatment (immediate death), which was Can$93,008 per QALY gained. High-efficiency OL-HDF can be considered a cost-effective treatment for ESRD in a Canadian setting. Further research is needed to assess cost effectiveness in other settings and healthcare systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, P; Kuo, L; Yorke, E
Purpose: To develop a biological modeling strategy which incorporates the response observed on the mid-treatment PET/CT into a dose escalation design for adaptive radiotherapy of non-small-cell lung cancer. Method: FDG-PET/CT was acquired midway through standard fractionated treatment and registered to pre-treatment planning PET/CT to evaluate radiation response of lung cancer. Each mid-treatment PET voxel was assigned the median SUV inside a concentric 1cm-diameter sphere to account for registration and imaging uncertainties. For each voxel, the planned radiation dose, pre- and mid-treatment SUVs were used to parameterize the linear-quadratic model, which was then utilized to predict the SUV distribution after themore » full prescribed dose. Voxels with predicted post-treatment SUV≥2 were identified as the resistant target (response arm). An adaptive simultaneous integrated boost was designed to escalate dose to the resistant target as high as possible, while keeping prescription dose to the original target and lung toxicity intact. In contrast, an adaptive target volume was delineated based only on the intensity of mid-treatment PET/CT (intensity arm), and a similar adaptive boost plan was optimized. The dose escalation capability of the two approaches was compared. Result: Images of three patients were used in this planning study. For one patient, SUV prediction indicated complete response and no necessary dose escalation. For the other two, resistant targets defined in the response arm were multifocal, and on average accounted for 25% of the pre-treatment target, compared to 67% in the intensity arm. The smaller response arm targets led to a 6Gy higher mean target dose in the adaptive escalation design. Conclusion: This pilot study suggests that adaptive dose escalation to a biologically resistant target predicted from a pre- and mid-treatment PET/CT may be more effective than escalation based on the mid-treatment PET/CT alone. More plans and ultimately clinical protocols are needed to validate this approach. MSKCC has a research agreement with Varian Medical System.« less
2013-01-01
Background Supporting self-management behaviours is recommended guidance for people with asthma. Preliminary work suggests that a brief, intensive, patient-centred intervention may be successful in supporting people with asthma to participate in life roles and activities they value. We seek to assess the feasibility of undertaking a cluster-randomised controlled trial (cRCT) of a brief, goal-setting intervention delivered in the context of an asthma review consultation. Methods/design A two armed, single-blinded, multi-centre, cluster-randomised controlled feasibility trial will be conducted in UK primary care. Randomisation will take place at the practice level. We aim to recruit a total of 80 primary care patients with active asthma from at least eight practices across two health boards in Scotland (10 patients per practice resulting in ~40 in each arm). Patients in the intervention arm will be asked to complete a novel goal-setting tool immediately prior to an asthma review consultation. This will be used to underpin a focussed discussion about their goals during the asthma review. A tailored management plan will then be negotiated to facilitate achieving their prioritised goals. Patients in the control arm will receive a usual care guideline-based review of asthma. Data on quality of life, asthma control and patient confidence will be collected from both arms at baseline and 3 and 6 months post-intervention. Data on health services resource use will be collected from all patient records 6 months pre- and post-intervention. Semi-structured interviews will be carried out with healthcare staff and a purposive sample of patients to elicit their views and experiences of the trial. The outcomes of interest in this feasibility trial are the ability to recruit patients and healthcare staff, the optimal method of delivering the intervention within routine clinical practice, and acceptability and perceived utility of the intervention among patients and staff. Trial registration ISRCTN18912042 PMID:24021033
NASA Astrophysics Data System (ADS)
Reeves, D.; Mazanek, D. D.; Abell, P. A.; Brophy, J. R.; Chodas, P. W.; Cichy, B. D.
2016-12-01
The National Aeronautics and Space Administration (NASA) is developing the Asteroid Redirect Mission (ARM) to robotically visit a large near-Earth asteroid (NEA), collect a multi-ton boulder and regolith samples from its surface, demonstrate the enhanced gravity tractor (EGT) planetary defense technique, return the asteroidal material to a stable orbit around the Moon, and explore the returned material with a crewed mission in the mid-2020s. Recent analysis of the EGT has led to a change in the robotic baseline operations from a halo orbit, to an in-line stand-off. This study took into account the uncertainties in size and mass of the current reference target (2008 EV5), the desire to be able to perform the EGT operations with the collected boulder augmenting the spacecraft mass or with the spacecraft alone, the assumed capability of the ARM solar electric propulsion (SEP) system, and the extensibility to future planetary defense missions. This presentation will cover the findings that led to this change in the baseline, as well as the benefits that this EGT demonstration will provide. ARM is a capability and technology demonstration mission, which will also benefit our understanding of small bodies in the areas of science, planetary defense, and asteroidal resources and in-situ resource utilization (ISRU). The synergistic benefits of both the robotic and crewed segments will be discussed in addition to describing ARM's interaction with communities that are interested in small bodies, including: the Formulation Assessment and Support Team (FAST) effort, the Small Bodies Assessment Group (SBAG) Special Action Team (SAT) effort, and the upcoming Investigation Team (IT). The IT, which is expected to be announced in the spring of 2017, will assist the ARM project in the definition, design, development, and operations phases of the ARRM with the goal of maximizing the probability of mission success and the knowledge return from the mission.
Formulation Assessment and Support Team (FAST) for the Asteroid Redirect Mission (ARM)
NASA Astrophysics Data System (ADS)
Mazanek, Daniel D.; Abell, Paul; Reeves, David M.; NASA Asteroid Redirect Mission (ARM) Formulation Assessment and Support Team (FAST)
2016-10-01
The Formulation Assessment and Support Team (FAST) for the Asteroid Redirect Mission (ARM) was a two-month effort, chartered by NASA, to provide timely inputs for mission requirement formulation in support of the Asteroid Redirect Robotic Mission (ARRM) Requirements Closure Technical Interchange Meeting held December 15-16, 2015. Additionally, the FAST was tasked with developing an initial list of potential mission investigations and providing input on potential hosted payloads and partnerships. The FAST explored several aspects of potential science benefits and knowledge gain from the ARM. Expertise from the science, engineering, and technology communities was represented in exploring lines of inquiry related to key characteristics of the ARRM reference target asteroid (2008 EV5) for engineering design purposes. Specific areas of interest included target origin, spatial distribution and size of boulders, surface geotechnical properties, boulder physical properties, and considerations for boulder handling, crew safety, and containment. In order to increase knowledge gain potential from the mission, opportunities for partnerships and accompanying payloads that could be provided by domestic and international partners were also investigated. The ARM FAST final report was publicly released on February 18, 2016 and represents the FAST's final product. The report and associated public comments are being used to support mission requirements formulation and serve as an initial inquiry to the science and engineering communities relating to the characteristics of the ARRM reference target asteroid. This report also provides a suggested list of potential investigations sorted and grouped based on their likely benefit to ARM and potential relevance to NASA science and exploration goals. These potential investigations could be conducted to reduce mission risks and increase knowledge return in the areas of science, planetary defense, asteroid resources and in-situ resource utilization (ISRU), and capability and technology demonstrations. This summary presentation will provide an overview of the FAST's effort and associated final report.
NASA Astrophysics Data System (ADS)
Shukitt-Hale, Barbara; Miller, Marshall; Carrihill-Knoll, Kirsty; Rabin, Bernard; Joseph, James
Previous research has shown that radiation exposure, particularly to particles of high energy and charge (HZE particles) which will be encountered on long-term space missions, can adversely affect the ability of rats to perform a variety of behavioral tasks. This outcome has implications for an astronaut's ability to successfully complete requirements associated with these missions. Both aged and irradiated rats display cognitive impairment in tests of spatial learning and memory such as the Morris water maze and the radial arm maze. Therefore, in the present study, we used a combination of these two tests, the 8 arm radial water maze (RAWM), to measure spatial learning in rats which were irradiated at the NSRL with 0, 150cGy, or 200cGy of 56Fe radiation. Following irradiation the rats were shipped to the HNRCA and tested in the RAWM (2-3 months later) for 5 days, 3 trials/day. In this version of the RAWM, there were 4 hidden platforms that the rat needed to locate to successfully solve a trial. Once the rat located a platform, it was allowed to remain there for 15 sec before the platform sank, at which point the rat tried to locate the remaining ones. Reference (entering an arm that never contained the platform) and working (re-entering an arm in which the platform had already been found) memory errors were tabulated. Results showed that the irradiated rats had more reference and working memory errors while learning the maze, particularly on Day 3 of testing. Additionally, they utilized non-spatial strategies to solve the RAWM task whereas the control animals used spatial strategies. These results show that irradiation with 56Fe high-energy particles produces age-like decrements in cognitive behavior that may impair the ability of astronauts to perform critical tasks during long-term space travel beyond the magnetosphere. Supported by USDA Intramural and N.A.S.A. Grant NNX08AM66G
Green, Nicole A; Durani, Yamini; Brecher, Deena; DePiero, Andrew; Loiselle, John; Attia, Magdy
2012-08-01
The Emergency Severity Index version 4 (ESI v.4) is the most recently implemented 5-level triage system. The validity and reliability of this triage tool in the pediatric population have not been extensively established. The goals of this study were to assess the validity of ESI v.4 in predicting hospital admission, emergency department (ED) length of stay (LOS), and number of resources utilized, as well as its reliability in a prospective cohort of pediatric patients. The first arm of the study was a retrospective chart review of 780 pediatric patients presenting to a pediatric ED to determine the validity of ESI v.4. Abstracted data included acuity level assigned by the triage nurse using ESI v.4 algorithm, disposition (admission vs discharge), LOS, and number of resources utilized in the ED. To analyze the validity of ESI v.4, patients were divided into 2 groups for comparison: higher-acuity patients (ESI levels 1, 2, and 3) and lower-acuity patients (ESI levels 4 and 5). Pearson χ analysis was performed for categorical variables. For continuous variables, we conducted a comparison of means based on parametric distribution of variables. The second arm was a prospective cohort study to determine the interrater reliability of ESI v.4 among and between pediatric triage (PT) nurses and pediatric emergency medicine (PEM) physicians. Three raters (2 PT nurses and 1 PEM physician) independently assigned triage scores to 100 patients; k and interclass correlation coefficient were calculated among PT nurses and between the primary PT nurses and physicians. In the validity arm, the distribution of ESI score levels among the 780 cases are as follows: ESI 1: 2 (0.25%); ESI 2: 73 (9.4%); ESI 3: 289 (37%); ESI 4: 251 (32%); and ESI 5: 165 (21%). Hospital admission rates by ESI level were 1: 100%, 2: 42%, 3: 14.9%, 4: 1.2%, and 5: 0.6%. The admission rate of the higher-acuity group (76/364, 21%) was significantly greater than the lower-acuity group (4/415, 0.96%), P < 0.001. The mean ED LOS (in minutes) for the higher-acuity group was 257 (SD, 132) versus 143 (SD, 81) in the lower-acuity group, P < 0.001. The higher-acuity group also had significantly greater use of resources than the lower-acuity group, P < 0.001. The percentage of low-acuity patients receiving no resources was 54%, compared with only 26% in the higher-acuity group. Conversely, a greater percentage of higher-acuity patients utilized 2 or more resources than the lower-acuity cohorts, 43% vs 12%, respectively, P < 0.001. In the prospective reliability arm of the study, 15 PT nurses and 8 PEM attending physicians participated in the study; k among nurses was 0.92 and between the primary triage nurses and physicians was 0.78, P < 0.001. The intraclass correlation coefficient was 0.96 for PT nurses and 0.91 between the primary triage nurse and physicians, P < 0.001. Emergency Severity Index v.4 is a valid predictor of hospital admission, ED LOS, and resource utilization in the pediatric ED population. It is a reliable pediatric triage instrument with high agreement among PT nurses and between PT nurses and PEM physicians.
Bucalo, B D; Mirikitani, E J; Moy, R L
1998-05-01
Liposomes are microscopic phospholipid vessels that have been utilized to extend the action of topical medications. Previous studies have demonstrated that liposomal vehicles can prolong the action of a variety of medications, including antifungals, anesthetics, interferon, and antineoplastic agents. The purpose of this study was to examine the degree and duration of anesthesia produced by lidocaine in a liposomal vehicle compared with lidocaine in a nonliposomal vehicle and compared with EMLA. The topical preparations in this study were allowed to contact the skin for a 30-minute period prior to evaluation of anesthetic effectiveness. Unoccluded and Tegaderm-occluded topical preparations were evaluated in two separate arms of the study. Thirteen healthy volunteers (three male, 10 female) were recruited for the nonocclusion arm of the study. Six healthy volunteers (two male, four female) were recruited for the occlusion arm of the study. Subjects with a history of allergy to lidocaine, a history of seizures, cardiac or respiratory difficulty, pregnant patients, and patients less than 18 years old were excluded. Written informed consent was obtained from all patients prior to testing. The volar forearms of the volunteers were swabbed with isopropyl alcohol and allowed to dry. A template was then utilized to mark 2 x 2-cm squares with a skin marker on both volar forearms. In total, nine squares corresponding to nine test areas were marked. The nine test preparations were applied to the test areas in a double-blinded fashion using a clean swab stick. The test preparations were then allowed to remain on the skin for 30 minutes in either occluded or nonoccluded from depending upon the arm of the study. Following the 30-minute application period, the test preparations were wiped off with clean gauze. Testing for anesthesia was performed by following a previously published method utilizing gentle pinpricks. A new pinprick apparatus was used for each patient. Pinprick testing was performed at 0, 15, 30, 60, and 90 minutes following the end of the 30-minute application period. Patients' responses to the pinprick were recorded in a binary fashion, as being either: 1) totally painless or 0) painfully sharp to any degree. Ten applications of the pinprick were applied randomly across each 2 x 2-cm test area. The number of painless applications of the pinprick out of a total of 10 applications of the pinprick was then recorded for each test area at every particular test time. In total, nine test preparations were evaluated. Analysis of the data was performed by a PhD statistical faculty consultant from the UCLA Mathematics Department. Liposomal lidocaine preparations evidenced longer durations of anesthesia than lidocaine preparations in nonliposomal vehicles. Five percent liposomal lidocaine preparations were statistically equivalent to EMLA in anesthetic effectiveness. Five percent liposomal lidocaine is an effective alternative topical agent for use in the attainment of temporary local anesthesia of the skin.
Carreon, Leah Y; Bratcher, Kelly R; Das, Nandita; Nienhuis, Jacob B; Glassman, Steven D
2014-09-01
The Neck Disability Index (NDI) and numeric rating scales (0 to 10) for neck pain and arm pain are widely used cervical spine disease-specific measures. Recent studies have shown that there is a strong relationship between the SF-6D and the NDI such that using a simple linear regression allows for the estimation of an SF-6D value from the NDI alone. Due to ease of administration and scoring, the EQ-5D is increasingly being used as a measure of utility in the clinical setting. The purpose of this study is to determine if the EQ-5D values can be estimated from commonly available cervical spine disease-specific health-related quality of life measures, much like the SF-6D. The EQ-5D, NDI, neck pain score, and arm pain score were prospectively collected in 3732 patients who presented to the authors' clinic with degenerative cervical spine disorders. Correlation coefficients for paired observations from multiple time points between the NDI, neck pain and arm pain scores, and EQ-5D were determined. Regression models were built to estimate the EQ-5D values from the NDI, neck pain, and arm pain scores. The mean age of the 3732 patients was 53.3 ± 12.2 years, and 43% were male. Correlations between the EQ-5D and the NDI, neck pain score, and arm pain score were statistically significant (p < 0.0001), with correlation coefficients of -0.77, -0.62, and -0.50, respectively. The regression equation 0.98947 + (-0.00705 × NDI) + (-0.00875 × arm pain score) + (-0.00877 × neck pain score) to predict EQ-5D had an R-square of 0.62 and a root mean square error (RMSE) of 0.146. The model using NDI alone had an R-square of 0.59 and a RMSE of 0.150. The model using the individual NDI items had an R-square of 0.46 and an RMSE of 0.172. The correlation coefficient between the observed and estimated EQ-5D scores was 0.79. There was no statistically significant difference between the actual EQ-5D score (0.603 ± 0.235) and the estimated EQ-5D score (0.603 ± 0.185) using the NDI, neck pain score, and arm pain score regression model. However, rounding off the coefficients to fewer than 5 decimal places produced less accurate results. The regression model estimating the EQ-5D from the NDI, neck pain score, and arm pain score accounted for 60% of the variability of the EQ-5D with a relatively large RMSE. This regression model may not be sufficient to accurately or reliably estimate actual EQ-5D values.
Critical Technologies Plan for the Committees on Armed Services, United States Congress. Revision
1989-05-05
materials; however, it does not appear to be a concerted effort. Only the British have a space-qualified cryocooler . This Stirling cooler has been life...published results of innovative concepts utilizing pulse tube refrigerators and appear to be far ahead of the US in this technology. A-61 11. AUTOMATIC...12. PERSONAL AUTHOR(S) 13a. TYPE OF REPORT 113b. TIME COVERED 114. DATE OF REPORT (Year, Month, Day) 5. PAGE COUNT1aTYEOREOT 7 FROM TO - 1989 MAY 05
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morgansen, K.A.; Pin, F.G.
A new method for mitigating unexpected impact of a redundant manipulator with an object in its environment is presented. Kinematic constraints are utilized with the recently developed method known as Full Space Parameterization (FSP). System performance criterion and constraints are changed at impact to return the end effector to the point of impact and halt the arm. Since large joint accelerations could occur as the manipulator is halted, joint acceleration bounds are imposed to simulate physical actuator limitations. Simulation results are presented for the case of a simple redundant planar manipulator.
2013-03-21
leadership style between the generations may not differ, defining characteristics of how a leader communicates and overcoming generational stereotypes become...in command, is not immune to generational stereotypes and must maintain a professional tradition of arms while appreciating the nuances of Generation...6 DEFINING GENERATIONAL TRAITS AND STEREOTYPES …………...…...........................6 Defining Baby Boomer Stereotypes …………………………………..…..…..…………..8
NASA Technical Reports Server (NTRS)
Ethridge, E. C.; Curreri, P. A.; Kelly, M.
1984-01-01
The final results of the Drop Tube Solidification of NiAl3 are presented. Problems associated with the utilization of a dripper furnace in the drop tube are discussed and the modification of experimental procedures required to achieve results are described. Sample microstructures of drop tube samples are compared with other samples. The dendrite arm spacings of drop tube samples are correlated with the rapid cooling rates.
NASA Astrophysics Data System (ADS)
Lee, Choonsik; Lee, Choonik; Lee, Jai-Ki
2006-11-01
Distributions of radiation absorbed dose within human anatomy have been estimated through Monte Carlo radiation transport techniques implemented for two different classes of computational anthropomorphic phantoms: (1) mathematical equation-based stylized phantoms and (2) tomographic image-based voxel phantoms. Voxel phantoms constructed from tomographic images of real human anatomy have been actively developed since the late 1980s to overcome the anatomical approximations necessary with stylized phantoms, which themselves have been utilized since the mid 1960s. However, revisions of stylized phantoms have also been pursued in parallel to the development of voxel phantoms since voxel phantoms (1) are initially restricted to the individual-specific anatomy of the person originally imaged, (2) must be restructured on an organ-by-organ basis to conform to reference individual anatomy and (3) cannot easily represent very fine anatomical structures and tissue layers that are thinner than the voxel dimensions of the overall phantom. Although efforts have been made to improve the anatomic realism of stylized phantoms, most of these efforts have been limited to attempts to alter internal organ structures. Aside from the internal organs, the exterior shapes, and especially the arm structures, of stylized phantoms are also far from realistic descriptions of human anatomy, and may cause dosimetry errors in the calculation of organ-absorbed doses for external irradiation scenarios. The present study was intended to highlight the need to revise the existing arm structure within stylized phantoms by comparing organ doses of stylized adult phantoms with those from three adult voxel phantoms in the lateral photon irradiation geometry. The representative stylized phantom, the adult phantom of the Oak Ridge National Laboratory (ORNL) series and two adult male voxel phantoms, KTMAN-2 and VOXTISS8, were employed for Monte Carlo dose calculation, and data from another voxel phantom, VIP-Man, were obtained from literature sources. The absorbed doses for lungs, oesophagus, liver and kidneys that could be affected by arm structures in the lateral irradiation geometry were obtained for both classes of phantoms in lateral monoenergetic photon irradiation geometries. As expected, those organs in the ORNL phantoms received apparently higher absorbed doses than those in the voxel phantoms. The overestimation is mainly attributed to the relatively poor representation of the arm structure in the ORNL phantom in which the arm bones are embedded within the regions describing the phantom's torso. The results of this study suggest that the overestimation of organ doses, due to unrealistic arm representation, should be taken into account when stylized phantoms are employed for equivalent or effective dose estimates, especially in the case of an irradiation scenario with dominating lateral exposure. For such a reason, the stylized phantom arm structure definition should be revised in order to obtain more realistic evaluations.
The opto-mechanical design for GMOX: a next-generation instrument concept for Gemini
NASA Astrophysics Data System (ADS)
Smee, Stephen A.; Barkhouser, Robert; Robberto, Massimo; Ninkov, Zoran; Gennaro, Mario; Heckman, Timothy M.
2016-08-01
We present the opto-mechanical design of GMOX, the Gemini Multi-Object eXtra-wide-band spectrograph, a potential next-generation (Gen-4 #3) facility-class instrument for Gemini. GMOX is a wide-band, multi-object, spectrograph with spectral coverage spanning 350 nm to 2.4 um with a nominal resolving power of R 5000. Through the use of Digital Micromirror Device (DMD) technology, GMOX will be able to acquire spectra from hundreds of sources simultaneously, offering unparalleled flexibility in target selection. Utilizing this technology, GMOX can rapidly adapt individual slits to either seeing-limited or diffraction-limited conditions. The optical design splits the bandpass into three arms, blue, red, and near infrared, with the near-infrared arm being split into three channels covering the Y+J band, H band, and K band. A slit viewing camera in each arm provides imaging capability for target acquisition and fast-feedback for adaptive optics control with either ALTAIR (Gemini North) or GeMS (Gemini South). Mounted at the Cassegrain focus, GMOX is a large (1.3 m x 2.8 m x 2.0 m) complex instrument, with six dichroics, three DMDs (one per arm), five science cameras, and three acquisition cameras. Roughly half of these optics, including one DMD, operate at cryogenic temperature. To maximize stiffness and simplify assembly and alignment, the opto-mechanics are divided into three main sub-assemblies, including a near-infrared cryostat, each having sub-benches to facilitate ease of alignment and testing of the optics. In this paper we present the conceptual opto-mechanical design of GMOX, with an emphasis on the mounting strategy for the optics and the thermal design details related to the near-infrared cryostat.
Miller, Michelle; Wong, Wing Ki; Wu, Jing; Cavenett, Sally; Daniels, Lynne; Crotty, Maria
2008-10-01
To evaluate the utility of body mass index (BMI) and corrected-arm-muscle area (CAMA) as measures of nutritional health for lower-limb amputees attending prosthetics clinics. Cross-sectional study. Prosthetics clinic in Australia. Unilateral lower-extremity amputees (N=58; age range, 21-91y; 37 transtibial, 21 transfemoral) attending a regional prosthetics clinic between May and November 2003. Not applicable. Weight (without prosthesis), corrected and uncorrected for the amputated limb was used with height estimated from knee height to calculate corrected BMI (cBMI) and uncorrected BMI (uBMI). CAMA was calculated using the mean of triplicate mid-upper-arm circumference (MUAC) and triceps skinfold thickness (TST) measurements. The Mini Nutritional Assessment (MNA) and Assessment of Quality of Life were administered according to recommended protocols. The Pearson correlation was used to determine the strength and significance of associations between variables, and bivariate regression analyses were performed to determine whether an association existed between the nutritional variables (BMI, CAMA, MNA) and quality of life (QOL). There were no statistically significant differences in the measures of nutritional health according to site (transtibial, transfemoral) of amputation. MUAC, TST, and CAMA all showed moderate to high positive correlations (r range, .541-.782) with both cBMI and uBMI. The strength of the relationship between the MNA and cBMI/uBMI was weaker (r=.383, r=.380, respectively) but remained positive and statistically significant (P=.003). QOL was not associated with cBMI or uBMI but was related to CAMA (beta=-.132; P=.030) and MNA (beta=-.561; P=.017). For persons with unilateral lower-extremity amputation, measurement of upper-arm anthropometry may be a more useful indicator of nutritional health and its consequences than BMI.
Williamson, Donald A; Champagne, Catherine M; Harsha, David W; Han, Hongmei; Martin, Corby K; Newton, Robert L; Sothern, Melinda S; Stewart, Tiffany M; Webber, Larry S; Ryan, Donna H
2012-08-01
This study tested the efficacy of two school-based programs for prevention of body weight/fat gain in comparison to a control group, in all participants and in overweight children. The Louisiana (LA) Health study utilized a longitudinal, cluster randomized three-arm controlled design, with 28 months of follow-up. Children (N = 2,060; mean age = 10.5 years, SD = 1.2) from rural communities in grades 4-6 participated in the study. Seventeen school clusters (mean = 123 children/cluster) were randomly assigned to one of three prevention arms: (i) primary prevention (PP), an environmental modification (EM) program, (ii) primary + secondary prevention (PP+SP), the environmental program with an added classroom and internet education component, or (iii) control (C). Primary outcomes were changes in percent body fat and BMI z scores. Secondary outcomes were changes in behaviors related to energy balance. Comparisons of PP, PP+SP, and C on changes in body fat and BMI z scores found no differences. PP and PP+SP study arms were combined to create an EM arm. Relative to C, EM decreased body fat for boys (-1.7 ± 0.38% vs. -0.14 ± 0.69%) and attenuated fat gain for girls (2.9 ± 0.22% vs. 3.93 ± 0.37%), but standardized effect sizes were relatively small (<0.30). In conclusion, this school-based EM programs had modest beneficial effects on changes in percent body fat. Addition of a classroom/internet program to the environmental program did not enhance weight/fat gain prevention, but did impact physical activity and social support in overweight children.
Hidding, Janine T; Beurskens, Carien H G; van der Wees, Philip J; van Laarhoven, Hanneke W M; Nijhuis-van der Sanden, Maria W G
2014-01-01
Breast cancer is the most common type of cancer in women in the developed world. As a result of breast cancer treatment, many patients suffer from serious complaints in their arm and shoulder, leading to limitations in activities of daily living and participation. In this systematic literature review we present an overview of the adverse effects of the integrated breast cancer treatment related to impairment in functions and structures in the upper extremity and upper body and limitations in daily activities. Patients at highest risk were defined. We conducted a systematic literature search using the databases of PubMed, Embase, CINAHL and Cochrane from 2000 to October 2012, according to the PRISMA guidelines. Included were studies with patients with stage I-III breast cancer, treated with surgery and additional treatments (radiotherapy, chemotherapy and hormonal therapy). The following health outcomes were extracted: reduced joint mobility, reduced muscle strength, pain, lymphedema and limitations in daily activities. Outcomes were divided in within the first 12 months and >12 months post-operatively. Patients treated with ALND are at the highest risk of developing impairments of the arm and shoulder. Reduced ROM and muscle strength, pain, lymphedema and decreased degree of activities in daily living were reported most frequently in relation to ALND. Lumpectomy was related to a decline in the level of activities of daily living. Radiotherapy and hormonal therapy were the main risk factors for pain. Patients treated with ALND require special attention to detect and consequently address impairments in the arm and shoulder. Patients with pain should be monitored carefully, because pain limits the degree of daily activities. Future research has to describe a complete overview of the medical treatment and analyze outcome in relation to the treatment. Utilization of uniform validated measurement instruments has to be encouraged.
Hendrix, James L.
1995-01-01
A laser initiated ordnance controller apparatus which provides a safe and m scheme with no moving parts. The safe & arm apparatus provides isolation of firing energy to explosive devices using a combination of polarization isolation and control through acousto-optical deviation of laser energy pulses. The apparatus provides constant monitoring of the systems status and performs 100% built-in-test at any time prior to ordnance ignition without the risk of premature ignition or detonation. The apparatus has a computer controller, a solid state laser, an acousto-optic deflector and RF drive circuitry, built-in-test optics and electronics, and system monitoring capabilities. The optical system is completed from the laser beam power source to the pyrotechnic ordnance through fiber optic cabling, optical splitters and optical connectors. During operation of the apparatus, a command is provided by the computer controller and, simultaneous with laser flashlamp fire, the safe & arm device is opened for approximately 200 microseconds which allows the laser pulse to transmit through the device. The arm signal also energizes the laser power supply and activates the acousto-optical deflector. When the correct fire format command is received, the acousto-optic deflector moves to the selected event channel, and the channel is verified to ensure the system is pointing to the correct position. Laser energy is transmitted through the fiber where an ignitor or detonator designed to be sensitive to optical pulses is fired at the end of the fiber channel. Simultaneous event channels may also be utilized by optically splitting a single event channel. The built-in-test may be performed anytime prior to ordnance ignition.
Risk Factors for Musculoskeletal Symptoms Among Korean Broadcast Actors.
Park, Moon-Hee; Kim, Ham-Gyum; Cho, Jae-Hwan
2015-01-01
Musculoskeletal diseases (MSDs) are functional disabilities in the musculoskeletal area that occur when continuous damage to the muscles or tissues is caused by performing a repetitive task. These diseases are usually found in the waist, shoulder, neck, arm, and wrist. MSD is also referred to as cumulative trauma disorder, repetitive strain injury, occupational overuse syndrome, and visual display terminal, depending on the country. The condition is now commonly referred to as work-related musculoskeletal disorder. The aim of this study was to develop a prevention plan against musculoskeletal disease and to provide better health care to broadcast actors by understanding the association between musculoskeletal symptoms and working conditions. The results of the study can be utilized to maintain effective systematic resources to treat such diseases. A survey was conducted in Seoul between January 1 and May 10, 2014 with broadcast actors working in the South Korean entertainment industry. Tests with respect to musculoskeletal symptoms indicated that the study participants were likely to experience having musculoskeletal symptoms in the shoulders, waist, neck, leg/foot, hand/wrist/finger, and arm/elbow. Most of the participants reported pain on both sides of their shoulders and in their legs/feet or on the right side of the arm/elbow and in hand/wrist/finger. Pain lasted between 1 and 7 days, with an incidence of 33.8% in the neck, 36% in the shoulders, 33.3% in the arm/elbow, 47.4% in the hand/wrist/finger, 34.7% in the waist, and 39.3% in the leg/foot. This study should prove useful in determining systematic and effective resources to prevent broadcast actors from developing MSD in the future. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
Ridde, Valéry; Turcotte-Tremblay, Anne-Marie; Souares, Aurélia; Lohmann, Julia; Zombré, David; Koulidiati, Jean Louis; Yaogo, Maurice; Hien, Hervé; Hunt, Matthew; Zongo, Sylvie; De Allegri, Manuela
2014-10-12
The low quality of healthcare and the presence of user fees in Burkina Faso contribute to low utilization of healthcare and elevated levels of mortality. To improve access to high-quality healthcare and equity, national authorities are testing different intervention arms that combine performance-based financing with community-based health insurance and pro-poor targeting. There is a need to evaluate the implementation of these unique approaches. We developed a research protocol to analyze the conditions that led to the emergence of these intervention arms, the fidelity between the activities initially planned and those conducted, the implementation and adaptation processes, the sustainability of the interventions, the possibilities for scaling them up, and their ethical implications. The study adopts a longitudinal multiple case study design with several embedded levels of analyses. To represent the diversity of contexts where the intervention arms are carried out, we will select three districts. Within districts, we will select both primary healthcare centers (n =18) representing different intervention arms and the district or regional hospital (n =3). We will select contrasted cases in relation to their initial performance (good, fair, poor). Over a period of 18 months, we will use quantitative and qualitative data collection and analytical tools to study these cases including in-depth interviews, participatory observation, research diaries, and questionnaires. We will give more weight to qualitative methods compared to quantitative methods. Performance-based financing is expanding rapidly across low- and middle-income countries. The results of this study will enable researchers and decision makers to gain a better understanding of the factors that can influence the implementation and the sustainability of complex interventions aiming to increase healthcare quality as well as equity.
Epstein, Andrew S; O'Reilly, Eileen M; Shuk, Elyse; Romano, Danielle; Li, Yuelin; Breitbart, William; Volandes, Angelo E
2018-05-02
No standard advance care planning (ACP) process exists in oncology. We previously developed and validated the values questions for Person-Centered Oncologic Care and Choices (P-COCC), a novel ACP intervention combining a patient values interview with an informational care goals video. To pilot study acceptability, and, using randomization, explore potential utility of P-COCC. Eligibility included patients with advanced gastrointestinal cancer cared for at a comprehensive cancer center. Participants were randomized 2:2:1 to P-COCC vs. video alone vs. usual care. Validated assessments of wellbeing and decisional conflict were completed. Participants in the P-COCC arm also completed 3 Likert scales (was the intervention helpful, comfortable, and recommended to others); a positive score on at least 1 of 3 indicated acceptability. Patients were screened from 9/2014-11/2016; 151 were consented and randomized, 99 whom completed study measures (most common attrition reason: disease progression or death). The primary aim was met: Among 33 participants, P-COCC was acceptable to 32 (97%, 95%CI: 0.84-0.99, p<0.001). Mean distress scores (0-10) increased (0.43) in the P-COCC arm but decreased in the video alone (-0.04) and usual care (-0.21) arms (p=0.03 and 0.04, P-COCC versus video alone and usual care arms, respectively). There were no significant pre-post change scores on other measures of wellbeing (e.g., anxiety, depression, stress), or intergroup differences in decisional conflict. Our values-based ACP paradigm is acceptable but may increase distress in cancer outpatients. Further studies are investigating the underpinnings of these effects and ways to best support cancer patients in ACP. Copyright © 2018. Published by Elsevier Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shen, Samuel S. P.
2013-09-01
The long-range goal of several past and current projects in our DOE-supported research has been the development of new and improved parameterizations of cloud-radiation effects and related processes, using ARM data, and the implementation and testing of these parameterizations in global models. The main objective of the present project being reported on here has been to develop and apply advanced statistical techniques, including Bayesian posterior estimates, to diagnose and evaluate features of both observed and simulated clouds. The research carried out under this project has been novel in two important ways. The first is that it is a key stepmore » in the development of practical stochastic cloud-radiation parameterizations, a new category of parameterizations that offers great promise for overcoming many shortcomings of conventional schemes. The second is that this work has brought powerful new tools to bear on the problem, because it has been an interdisciplinary collaboration between a meteorologist with long experience in ARM research (Somerville) and a mathematician who is an expert on a class of advanced statistical techniques that are well-suited for diagnosing model cloud simulations using ARM observations (Shen). The motivation and long-term goal underlying this work is the utilization of stochastic radiative transfer theory (Lane-Veron and Somerville, 2004; Lane et al., 2002) to develop a new class of parametric representations of cloud-radiation interactions and closely related processes for atmospheric models. The theoretical advantage of the stochastic approach is that it can accurately calculate the radiative heating rates through a broken cloud layer without requiring an exact description of the cloud geometry.« less
Turan, Janet M; Darbes, Lynae A; Musoke, Pamela L; Kwena, Zachary; Rogers, Anna Joy; Hatcher, Abigail M; Anderson, Jami L; Owino, George; Helova, Anna; Weke, Elly; Oyaro, Patrick; Bukusi, Elizabeth A
2018-03-01
Engaging both partners of a pregnant couple can enhance prevention of mother-to-child transmission of HIV and promote family health. We developed and piloted an intervention to promote couple collaboration in health during pregnancy and postpartum in southwestern Kenya. We utilized formative data and stakeholder input to inform development of a home-based couples intervention. Next, we randomized pregnant women to intervention (n = 64) or standard care (n = 63) arms, subsequently contacting their male partners for enrollment. In the intervention arm, lay health workers conducted couple home visits, including health education, couple relationship and communication skills, and offers of couple HIV testing and counseling (CHTC) services. Follow-up questionnaires were conducted 3 months postpartum (n = 114 women, 86 men). Baseline characteristics and health behaviors were examined by study arm using t-tests, chi-square tests, and regression analyses. Of the 127 women randomized, 96 of their partners participated in the study. Of 52 enrolled couples in the intervention arm, 94% completed at least one couple home visit. Over 93% of participants receiving couple home visits were satisfied and no adverse social consequences were reported. At follow-up, intervention couples had a 2.78 relative risk of having participated in CHTC during the study period compared with standard care couples (95% confidence interval: 1.63-4.75), and significant associations were observed in other key perinatal health behaviors. This pilot study revealed that a home-based couples intervention for pregnant women and male partners is acceptable, feasible, and has the potential to enhance CHTC and perinatal health behaviors, leading to improved health outcomes.
Williamson, D.A.; Champagne, C.M.; Harsha, D.; Han, H.; Martin, C.K.; Newton, R.L.; Sothern, M.; Stewart, T.M.; Webber, L.S.; Ryan, D.
2012-01-01
This study tested the efficacy of two school-based programs for prevention of body weight/fat gain in comparison to a control group, in all participants and in overweight children. The Louisiana (LA) Health study utilized a longitudinal, cluster randomized 3-arm controlled design, with 28 months of follow-up. Children (N=2060; M age = 10.5 years, SD = 1.2) from rural communities in Grades 4 to 6 participated in the study. 17 school clusters (M = 123 children/cluster) were randomly assigned to one of three prevention arms: 1) Primary Prevention (PP), an environmental modification program, 2) Primary + Secondary Prevention (PP+SP), the environmental program with an added classroom and internet education component, or 3) Control (C). Primary outcomes were changes in percent body fat and body mass index z scores. Secondary outcomes were changes in behaviors related to energy balance. Comparisons of PP, PP+SP, and C on changes in body fat and BMI z scores found no differences. PP and PP+SP study arms were combined to create an environmental modification arm (EM). Relative to C, EM decreased body fat for boys (−1.7% ± 0.38% versus −0.14% ± 0.69%) and attenuated fat gain for girls (2.9% ± 0.22% versus 3.93% ± 0.37%), but standardized effect sizes were relatively small (< 0.30). In conclusion, this school-based environmental modification programs had modest beneficial effects on changes in percent body fat. Addition of a classroom/internet program to the environmental program did not enhance weight/fat gain prevention, but did impact physical activity and social support in overweight children. PMID:22402733
Tunable hard X-ray spectrometer utilizing asymmetric planes of a quartz transmission crystal
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seely, John F., E-mail: seelyjf@gmail.com; Feldman, Uri; Henins, Albert
2016-05-15
A Cauchois type hard x-ray spectrometer was developed that utilizes the (301) diffraction planes at an asymmetric angle of 23.51° to the normal to the surface of a cylindrically curved quartz transmission crystal. The energy coverage is tunable by rotating the crystal and the detector arm, and spectra were recorded in the 8 keV to 20 keV range with greater than 2000 resolving power. The high resolution results from low aberrations enabled by the nearly perpendicular angle of the diffracted rays with the back surface of the crystal. By using other asymmetric planes of the same crystal and rotating tomore » selected angles, the spectrometer can operate with high resolution up to 50 keV.« less
Low abundance of the matrix arm of complex I in mitochondria predicts longevity in mice
Miwa, Satomi; Jow, Howsun; Baty, Karen; Johnson, Amy; Czapiewski, Rafal; Saretzki, Gabriele; Treumann, Achim; von Zglinicki, Thomas
2014-01-01
Mitochondrial function is an important determinant of the ageing process; however, the mitochondrial properties that enable longevity are not well understood. Here we show that optimal assembly of mitochondrial complex I predicts longevity in mice. Using an unbiased high-coverage high-confidence approach, we demonstrate that electron transport chain proteins, especially the matrix arm subunits of complex I, are decreased in young long-living mice, which is associated with improved complex I assembly, higher complex I-linked state 3 oxygen consumption rates and decreased superoxide production, whereas the opposite is seen in old mice. Disruption of complex I assembly reduces oxidative metabolism with concomitant increase in mitochondrial superoxide production. This is rescued by knockdown of the mitochondrial chaperone, prohibitin. Disrupted complex I assembly causes premature senescence in primary cells. We propose that lower abundance of free catalytic complex I components supports complex I assembly, efficacy of substrate utilization and minimal ROS production, enabling enhanced longevity. PMID:24815183
Ethics, rhetoric, and expectations: responsibilities and obligations of health care systems.
Foreman, Thomas
2014-09-01
Health care organization foundations and other fund-raising departments often function at an arm's length from the system at large. As such, operations related to their mandate to raise funds and market the organization do not receive the same level of ethical scrutiny brought to bear on other arms within the organization. An area that could benefit from a more focused ethics lens is the use of language and rhetoric employed in order to raise funds and market the organization. Such departments and divisions often utilize overblown promises of miracles and extraordinary advances to convince donors to contribute and to persuade the general public. The result can be a heightened sense of expectation on the part of patients, their families, and the general public as to what can realistically be achieved by the health care system, leading to disappointment and conflict when these expectations are not or cannot be met. This article suggests that such advertising and marketing be subject to the same advertising standards as other businesses.
Kobayashi, Shinya; Ishikawa, Tatsuya; Mutoh, Tatsushi; Hikichi, Kentaro; Suzuki, Akifumi
2012-01-01
Background: Surgical placement of a ventriculoperitoneal shunt (VPS) is the main strategy to manage hydrocephalus. However, the failure rate associated with placement of ventricular catheters remains high. Methods: A hybrid operating room, equipped with a flat-panel detector digital subtraction angiography system containing C-arm cone-beam computed tomography (CB-CT) imaging, has recently been developed and utilized to assist neurosurgical procedures. We have developed a novel technique using intraoperative fluoroscopy and a C-arm CB-CT system to facilitate accurate placement of a VPS. Results: Using this novel technique, 39 consecutive ventricular catheters were placed accurately, and no ventricular catheter failures were experienced during the follow-up period. Only two patients experienced obstruction of the VPS, both of which occurred in the extracranial portion of the shunt system. Conclusion: Surgical placement of a VPS assisted by flat panel detector CT-guided real-time fluoroscopy enabled accurate placement of ventricular catheters and was associated with a decreased need for shunt revision. PMID:23226605
Autonomous space processor for orbital debris
NASA Technical Reports Server (NTRS)
Ramohalli, Kumar; Campbell, David; Brockman, Jeff P.; Carter, Bruce; Donelson, Leslie; John, Lawrence E.; Marine, Micky C.; Rodina, Dan D.
1989-01-01
This work continues to develop advanced designs toward the ultimate goal of a GETAWAY SPECIAL to demonstrate economical removal of orbital debris utilizing local resources in orbit. The fundamental technical feasibility was demonstrated last year through theoretical calculations, quantitative computer animation, a solar focal point cutter, a robotic arm design and a subscale model. During this reporting period, several improvements are made in the solar cutter, such as auto track capabilities, better quality reflectors and a more versatile framework. The major advance has been in the design, fabrication and working demonstration of a ROBOTIC ARM that has several degrees of freedom. The functions were specifically tailored for the orbital debris handling. These advances are discussed here. Also a small fraction of the resources were allocated towards research in flame augmentation in SCRAMJETS for the NASP. Here, the fundamental advance was the attainment of Mach numbers up to 0.6 in the flame zone and a vastly improved injection system; the current work is expected to achieve supersonic combustion in the laboratory and an advanced monitoring system.
Closing of the Midcontinent-Rift - a far-field effect on Grenvillian compression
Cannon, W.F.
1994-01-01
The Midcontinent rift formed in the Laurentian supercontinent between 1109 and 1094 Ma. Soon after rifting, stresses changed from extensional to compressional, and the central graben of the rift was partly inverted by thrusting on original extensional faults. Thrusting culminated at about 1060 Ma but may have begun as early as 1080 Ma. On the southwest-trending arm of the rift, the crust was shortened about 30km; on the southeast-trending arm, strike-slip motion was dominant. The rift developed adjacent to the tectonically active Grenville province, and its rapid evolution from an extensional to a compressional feature at c1080 Ma was coincident with renewal of northwest-directed thrusting in the Grenville, probably caused by continent-continent collision. A zone of weak lithosphere created by rifting became the locus for deformation within the otherwise strong continental lithosphere. Stresses transmitted from the Grenville province utilized this weak zone to close and invert the rift. -Author
An application of data mining in district heating substations for improving energy performance
NASA Astrophysics Data System (ADS)
Xue, Puning; Zhou, Zhigang; Chen, Xin; Liu, Jing
2017-11-01
Automatic meter reading system is capable of collecting and storing a huge number of district heating (DH) data. However, the data obtained are rarely fully utilized. Data mining is a promising technology to discover potential interesting knowledge from vast data. This paper applies data mining methods to analyse the massive data for improving energy performance of DH substation. The technical approach contains three steps: data selection, cluster analysis and association rule mining (ARM). Two-heating-season data of a substation are used for case study. Cluster analysis identifies six distinct heating patterns based on the primary heat of the substation. ARM reveals that secondary pressure difference and secondary flow rate have a strong correlation. Using the discovered rules, a fault occurring in remote flow meter installed at secondary network is detected accurately. The application demonstrates that data mining techniques can effectively extrapolate potential useful knowledge to better understand substation operation strategies and improve substation energy performance.
Burkle, Frederick M; Kushner, Adam L; Giannou, Christos; Paterson, Mary A; Wren, Sherry M; Burnham, Gilbert
2018-05-07
ABSTRACTNo discipline has been impacted more by war and armed conflict than health care has. Health systems and health care providers are often the first victims, suffering increasingly heinous acts that cripple the essential health delivery and public health infrastructure necessary for the protection of civilian and military victims of the state at war. This commentary argues that current instructional opportunities to prepare health care providers fall short in both content and preparation, especially in those operational skill sets necessary to manage multiple challenges, threats, and violations under international humanitarian law and to perform triage management in a resource-poor medical setting. Utilizing a historical framework, the commentary addresses the transformation of the education and training of humanitarian health professionals from the Cold War to today followed by recommendations for the future. (Disaster Med Public Health Preparedness. 2018;page 1 of 14).
Fisher, Jeffrey D; Amico, K Rivet; Fisher, William A; Cornman, Deborah H; Shuper, Paul A; Trayling, Cynthia; Redding, Caroline; Barta, William; Lemieux, Anthony F; Altice, Frederick L; Dieckhaus, Kevin; Friedland, Gerald
2011-11-01
We evaluated the efficacy of LifeWindows, a theory-based, computer-administered antiretroviral (ARV) therapy adherence support intervention, delivered to HIV + patients at routine clinical care visits. 594 HIV + adults receiving HIV care at five clinics were randomized to intervention or control arms. Intervention vs. control impact in the intent-to-treat sample (including participants whose ARVs had been entirely discontinued, who infrequently attended care, or infrequently used LifeWindows) did not reach significance. Intervention impact in the On Protocol sample (328 intervention and control arm participants whose ARVs were not discontinued, who attended care and were exposed to LifeWindows regularly) was significant. On Protocol intervention vs. control participants achieved significantly higher levels of perfect 3-day ACTG-assessed adherence over time, with sensitivity analyses maintaining this effect down to 70% adherence. This study supports the utility of LifeWindows and illustrates that patients on ARVs who persist in care at clinical care sites can benefit from adherence promotion software.
Basal paravian functional anatomy illuminated by high-detail body outline
Wang, Xiaoli; Pittman, Michael; Zheng, Xiaoting; Kaye, Thomas G.; Falk, Amanda R.; Hartman, Scott A.; Xu, Xing
2017-01-01
Body shape is a fundamental expression of organismal biology, but its quantitative reconstruction in fossil vertebrates is rare. Due to the absence of fossilized soft tissue evidence, the functional consequences of basal paravian body shape and its implications for the origins of avians and flight are not yet fully understood. Here we reconstruct the quantitative body outline of a fossil paravian Anchiornis based on high-definition images of soft tissues revealed by laser-stimulated fluorescence. This body outline confirms patagia-bearing arms, drumstick-shaped legs and a slender tail, features that were probably widespread among paravians. Finely preserved details also reveal similarities in propatagial and footpad form between basal paravians and modern birds, extending their record to the Late Jurassic. The body outline and soft tissue details suggest significant functional decoupling between the legs and tail in at least some basal paravians. The number of seemingly modern propatagial traits hint that feathering was a significant factor in how basal paravians utilized arm, leg and tail function for aerodynamic benefit. PMID:28248287
STS-52 CANEX-2 Canadian Target Assembly (CTA) held by RMS over OV-102's PLB
1992-11-01
STS052-71-057 (22 Oct-1 Nov 1992) --- This 70mm frame, photographed with a handheld Hasselblad camera aimed through Columbia's aft flight deck windows, captures the operation of the Space Vision System (SVS) experiment above the cargo bay. Target dots have been placed on the Canadian Target Assembly (CTA), a small satellite, in the grasp of the Canadian-built remote manipulator system (RMS) arm. SVS utilized a Shuttle TV camera to monitor the dots strategically arranged on the satellite, to be tracked. As the satellite moved via the arm, the SVS computer measured the changing position of the dots and provided real-time television display of the location and orientation of the CTA. This type of displayed information is expected to help an operator guide the RMS or the Mobile Servicing System (MSS) of the future when berthing or deploying satellites. Also visible in the frame is the U.S. Microgravity Payload (USMP-01).
Ergonomic evaluation of a wearable assistive device for overhead work.
Rashedi, Ehsan; Kim, Sunwook; Nussbaum, Maury A; Agnew, Michael J
2014-01-01
Overhead work is an important risk factor for upper extremity (UE) musculoskeletal disorders. We examined the potential of a mechanical arm and an exoskeletal vest as a wearable assistive device (WADE) for overhead work. Twelve participants completed 10 minutes of simulated, intermittent overhead work, using each of three payloads (1.1, 3.4 and 8.1 kg) and with/without the WADE. Ratings of perceived discomfort (RPDs) and electromyography (EMG) were obtained for the upper arms, shoulders and low back. Using the WADE, UE RPDs decreased by ∼50% with the heavier payloads, whereas smaller (∼25%) and non-significant increases in low-back RPDs were found and were relatively independent of payload. Changes in RPDs with WADE use were consistent with physical demands indicated by EMG, though EMG-based differences in fatigue were less apparent. Participants generally preferred using the WADE, particularly with heavier payloads. These results supported the potential utility of a WADE as an intervention for overhead work.
Nguyen, Phung Anh; Yang, Hsuan-Chia; Xu, Rong; Li, Yu-Chuan Jack
2018-01-01
Traditional Chinese Medicine utilization has rapidly increased worldwide. However, there is limited database provides the information of TCM herbs and diseases. The study aims to identify and evaluate the meaningful associations between TCM herbs and breast cancer by using the association rule mining (ARM) techniques. We employed the ARM techniques for 19.9 million TCM prescriptions by using Taiwan National Health Insurance claim database from 1999 to 2013. 364 TCM herbs-breast cancer associations were derived from those prescriptions and were then filtered by their support of 20. Resulting of 296 associations were evaluated by comparing to a gold-standard that was curated information from Chinese-Wikipedia with the following terms, cancer, tumor, malignant. All 14 TCM herbs-breast cancer associations with their confidence of 1% were valid when compared to gold-standard. For other confidences, the statistical results showed consistently with high precisions. We thus succeed to identify the TCM herbs-breast cancer associations with useful techniques.
Type III CRISPR-Cas systems can provide redundancy to counteract viral escape from type I systems.
Silas, Sukrit; Lucas-Elio, Patricia; Jackson, Simon A; Aroca-Crevillén, Alejandra; Hansen, Loren L; Fineran, Peter C; Fire, Andrew Z; Sánchez-Amat, Antonio
2017-08-17
CRISPR-Cas-mediated defense utilizes information stored as spacers in CRISPR arrays to defend against genetic invaders. We define the mode of target interference and role in antiviral defense for two CRISPR-Cas systems in Marinomonas mediterranea . One system (type I-F) targets DNA. A second system (type III-B) is broadly capable of acquiring spacers in either orientation from RNA and DNA, and exhibits transcription-dependent DNA interference. Examining resistance to phages isolated from Mediterranean seagrass meadows, we found that the type III-B machinery co-opts type I-F CRISPR-RNAs. Sequencing and infectivity assessments of related bacterial and phage strains suggests an 'arms race' in which phage escape from the type I-F system can be overcome through use of type I-F spacers by a horizontally-acquired type III-B system. We propose that the phage-host arms race can drive selection for horizontal uptake and maintenance of promiscuous type III interference modules that supplement existing host type I CRISPR-Cas systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kollias, Pavlos
2017-04-23
With the vast upgrades to the ARM program radar measurement capabilities in 2010 and beyond, our ability to probe the 3D structure of clouds and associated precipitation has increased dramatically. This project build on the PI's and co-I's expertisein the analysis of radar observations. The first research thrust aims to document the 3D morphological (as depicted by the radar reflectivity structure) and 3D dynamical (cloud$-$scale eddies) structure of boundary layer clouds. Unraveling the 3D dynamical structure of stratocumulus and shallow cumulus clouds requires decomposition of the environmental wind contribution and particle sedimentation velocity from the observed radial Doppler velocity. Themore » second thrust proposes to unravel the mechanism of cumulus entrainment (location, scales) and its impact on microphysics utilizing radar measurements from the vertically pointing and new scanning radars at the ARM sites. The third research thrust requires the development of a cloud$-$tracking algorithm that monitors the properties of cloud.« less
NASA Technical Reports Server (NTRS)
Vest, Thomas W. (Inventor); Carden, James R. (Inventor); Norton, William E. (Inventor); Belcher, Jewell G. (Inventor)
1992-01-01
A prosthetic device for below-the-elbow amputees, having a C-shaped clamping mechanism for grasping cylindrical objects, is described. The clamping mechanism is pivotally mounted to a cuff that fits on the amputee's lower arm. The present invention is utilized by placing an arm that has been amputated below the elbow into the cuff. The clamping mechanism then serves as a hand whenever it becomes necessary for the amputee to grasp a cylindrical object such as a handle, a bar, a rod, etc. To grasp the cylindrical object, the object is jammed against the opening in the C-shaped spring, causing the spring to open, the object to pass to the center of the spring, and the spring to snap shut behind the object. Various sizes of clamping mechanisms can be provided and easily interchanged to accommodate a variety of diameters. With the extension that pivots and rotates, the clamping mechanism can be used in a variety of orientations. Thus, this invention provides the amputee with a clamping mechanism that can be used to perform a number of tasks.
Wallen, Gwenyth R; Middleton, Kimberly R; Ames, Nancy; Brooks, Alyssa T; Handel, Daniel
2014-01-01
Sickle cell disease (SCD) is the most common genetic disease in African-Americans, characterized by recurrent painful vaso-occlusive crises. Medical therapies for controlling or preventing crises are limited because of efficacy and/or toxicity. This is a randomized, controlled, single-crossover protocol of hypnosis for managing pain in SCD patients. Participants receive hypnosis from a trained hypnosis therapist followed by six weeks of self-hypnosis using digital media. Those in the control arm receive SCD education followed by a six-week waiting period before crossing over to the hypnosis arm of the study. Outcome measures include assessments of pain (frequency, intensity and quality), anxiety, coping strategies, sleep, depression, and health care utilization. To date, there are no published randomized, controlled trials evaluating the efficacy of hypnosis on SCD pain modulation in adults. Self-hypnosis for pain management may be helpful in modulating chronic pain, improving sleep quality, and decreasing use of narcotics in patients with SCD. TRIAL REGISTRATION ClinicalTrials.gov: NCT00393250 PMID:25520557
Holographic gunsights for small arms
NASA Astrophysics Data System (ADS)
Tai, Anthony M.; Sieczka, Eric J.; Radler, Richard; Upatnieks, Juris
1996-05-01
Holographic gunsights were first demonstrated in the mid 1970s by researchers at the Environmental Research Institute of Michigan (ERIM) under contracts with the Air Force and the Army. The sights utilized He-Ne gas lasers and were designed for use with large weapons systems. With the advent of low cost visible laser diode, ERIM formed a new company, EOTech, to develop, manufacture and market a holographic gun sight for small arms. A hologram is used to reconstruct the image of a reticle pattern that appears at the target plane. Unlike red-dot sights, virtually any reticle pattern, 2D or 3D, can be formed. The design challenges include an opto-mechanical package that is compact, light weight and low cost which can withstand recoils up to 4,000 Gs and provide fine elevation/windage pointing adjustments, and optics that are aberration-free and stable over a wide temperature range. Manufacturing challenges include the mass production of high quality holographic optics at low cost and the precision alignment of the very low f/number optics.
Assessment of active methods for removal of LEO debris
NASA Astrophysics Data System (ADS)
Hakima, Houman; Emami, M. Reza
2018-03-01
This paper investigates the applicability of five active methods for removal of large low Earth orbit debris. The removal methods, namely net, laser, electrodynamic tether, ion beam shepherd, and robotic arm, are selected based on a set of high-level space mission constraints. Mission level criteria are then utilized to assess the performance of each redirection method in light of the results obtained from a Monte Carlo simulation. The simulation provides an insight into the removal time, performance robustness, and propellant mass criteria for the targeted debris range. The remaining attributes are quantified based on the models provided in the literature, which take into account several important parameters pertaining to each removal method. The means of assigning attributes to each assessment criterion is discussed in detail. A systematic comparison is performed using two different assessment schemes: Analytical Hierarchy Process and utility-based approach. A third assessment technique, namely the potential-loss analysis, is utilized to highlight the effect of risks in each removal methods.
Co, Michael; Kwong, Ava
2017-04-01
Sentinel lymph node (SLN) biopsy is currently the gold standard of treatment in early breast cancers. Identification of SLNs by preoperative scintigraphy has been carried out to improve the detection of SLNs intraoperatively, but the evidence of its cost-effectiveness is lacking. Here, we analyze the cost-effectiveness of the utilization of scintigraphy in detection of SLNs. Clinical and operative details were retrieved from a prospectively maintained database. The resources and cost data from each patient who had undergone SLN biopsy with preoperative scintigraphy were retrieved. From January 2008 to December 2012, 400 patients underwent SLN biopsy for breast cancer. A total of 329 had preoperative SLN mapping with scintigraphy, Baseline patient demographic data for both arms were comparable. The relapse and recurrence rate of both arms were not statistically different. The detection rate of SLNs of both arms was the same (100%), and there were no grade 2 or above lymphedema in both groups of patients. However, the cost of each patient undergoing SLN mapping was USD $345.8. Preoperative SLN mapping does not improve the SLN detection rate. In addition, it does not affect the surgical outcomes in terms of complication, local relapse, and recurrence. The use of preoperative SLN mapping is no longer cost-effective. Copyright © 2016 Elsevier Inc. All rights reserved.
OSIRIS-REx Touch-and-Go (TAG) Mission Design for Asteroid Sample Collection
NASA Technical Reports Server (NTRS)
May, Alexander; Sutter, Brian; Linn, Timothy; Bierhaus, Beau; Berry, Kevin; Mink, Ron
2014-01-01
The Origins Spectral Interpretation Resource Identification Security Regolith Explorer (OSIRIS-REx) mission is a NASA New Frontiers mission launching in September 2016 to rendezvous with the near-Earth asteroid Bennu in October 2018. After several months of proximity operations to characterize the asteroid, OSIRIS-REx flies a Touch-And-Go (TAG) trajectory to the asteroid's surface to collect at least 60 g of pristine regolith sample for Earth return. This paper provides mission and flight system overviews, with more details on the TAG mission design and key events that occur to safely and successfully collect the sample. An overview of the navigation performed relative to a chosen sample site, along with the maneuvers to reach the desired site is described. Safety monitoring during descent is performed with onboard sensors providing an option to abort, troubleshoot, and try again if necessary. Sample collection occurs using a collection device at the end of an articulating robotic arm during a brief five second contact period, while a constant force spring mechanism in the arm assists to rebound the spacecraft away from the surface. Finally, the sample is measured quantitatively utilizing the law of conservation of angular momentum, along with qualitative data from imagery of the sampling device. Upon sample mass verification, the arm places the sample into the Stardust-heritage Sample Return Capsule (SRC) for return to Earth in September 2023.
Ji, Hanlee; Kumm, Jochen; Zhang, Michael; Farnam, Kyle; Salari, Keyan; Faham, Malek; Ford, James M.; Davis, Ronald W.
2006-01-01
Genomic instability is a major feature of neoplastic development in colorectal carcinoma and other cancers. Specific genomic instability events, such as deletions in chromosomes and other alterations in gene copy number, have potential utility as biologically relevant prognostic biomarkers. For example, genomic deletions on chromosome arm 18q are an indicator of colorectal carcinoma behavior and potentially useful as a prognostic indicator. Adapting a novel genomic technology called molecular inversion probes which can determine gene copy alterations, such as genomic deletions, we designed a set of probes to interrogate several hundred individual exons of >200 cancer genes with an overall distribution covering all chromosome arms. In addition, >100 probes were designed in close proximity of microsatellite markers on chromosome arm 18q. We analyzed a set of colorectal carcinoma cell lines and primary colorectal tumor samples for gene copy alterations and deletion mutations in exons. Based on clustering analysis, we distinguished the different categories of genomic instability among the colorectal cancer cell lines. Our analysis of primary tumors uncovered several distinct categories of colorectal carcinoma, each with specific patterns of 18q deletions and deletion mutations in specific genes. This finding has potential clinical ramifications given the application of 18q loss of heterozygosity events as a potential indicator for adjuvant treatment in stage II colorectal carcinoma. PMID:16912164
Investigating Astromaterials Curation Applications for Dexterous Robotic Arms
NASA Technical Reports Server (NTRS)
Snead, C. J.; Jang, J. H.; Cowden, T. R.; McCubbin, F. M.
2018-01-01
The Astromaterials Acquisition and Curation office at NASA Johnson Space Center is currently investigating tools and methods that will enable the curation of future astromaterials collections. Size and temperature constraints for astromaterials to be collected by current and future proposed missions will require the development of new robotic sample and tool handling capabilities. NASA Curation has investigated the application of robot arms in the past, and robotic 3-axis micromanipulators are currently in use for small particle curation in the Stardust and Cosmic Dust laboratories. While 3-axis micromanipulators have been extremely successful for activities involving the transfer of isolated particles in the 5-20 micron range (e.g. from microscope slide to epoxy bullet tip, beryllium SEM disk), their limited ranges of motion and lack of yaw, pitch, and roll degrees of freedom restrict their utility in other applications. For instance, curators removing particles from cosmic dust collectors by hand often employ scooping and rotating motions to successfully free trapped particles from the silicone oil coatings. Similar scooping and rotating motions are also employed when isolating a specific particle of interest from an aliquot of crushed meteorite. While cosmic dust curators have been remarkably successful with these kinds of particle manipulations using handheld tools, operator fatigue limits the number of particles that can be removed during a given extraction session. The challenges for curation of small particles will be exacerbated by mission requirements that samples be processed in N2 sample cabinets (i.e. gloveboxes). We have been investigating the use of compact robot arms to facilitate sample handling within gloveboxes. Six-axis robot arms potentially have applications beyond small particle manipulation. For instance, future sample return missions may involve biologically sensitive astromaterials that can be easily compromised by physical interaction with a curator; other potential future returned samples may require cryogenic curation. Robot arms may be combined with high resolution cameras within a sample cabinet and controlled remotely by curator. Sophisticated robot arm and hand combination systems can be programmed to mimic the movements of a curator wearing a data glove; successful implementation of such a system may ultimately allow a curator to virtually operate in a nitrogen, cryogenic, or biologically sensitive environment with dexterity comparable to that of a curator physically handling samples in a glove box.
NASA Astrophysics Data System (ADS)
Chudaničová, Monika; Hutchinson, Simon M.
2016-11-01
Our study attempts to identify a characteristic magnetic signature of overbank sediments exhibiting anthropogenically induced magnetic enhancement and thereby to distinguish them from unenhanced sediments with weak magnetic background values, using a novel approach based on data mining methods, thus providing a mean of rapid pollution determination. Data were obtained from 539 bulk samples from vertical profiles through overbank sediment, collected on seven rivers in the eastern Czech Republic and three rivers in northwest England. k-Means clustering and hierarchical clustering methods, paired group (UPGMA) and Ward's method, were used to divide the samples to natural groups according to their attributes. Interparametric ratios: SIRM/χ; SIRM/ARM; and S-0.1T were chosen as attributes for analyses making the resultant model more widely applicable as magnetic concentration values can differ by two orders. Division into three clusters appeared to be optimal and corresponded to inherent clusters in the data scatter. Clustering managed to separate samples with relatively weak anthropogenically induced enhancement, relatively strong anthropogenically induced enhancement and samples lacking enhancement. To describe the clusters explicitly and thus obtain a discrete magnetic signature, classification rules (JRip method) and decision trees (J4.8 and Simple Cart methods) were used. Samples lacking anthropogenic enhancement typically exhibited an S-0.1T < c. 0.5, SIRM/ARM < c. 150 and SIRM/χ < c. 6000 A m-1. Samples with magnetic enhancement all exhibited an S-0.1T > 0.5. Samples with relatively stronger anthropogenic enhancement were unequivocally distinguished from the samples with weaker enhancement by an SIRM/ARM > c. 150. Samples with SIRM/ARM in a range c. 126-150 were classified as relatively strongly enhanced when their SIRM/χ > 18 000 A m-1 and relatively less enhanced when their SIRM/χ < 18 000 A m-1. An additional rule was arbitrary added to exclude samples with χfd% > 6 per cent from anthropogenically enhanced clusters as samples with natural magnetic enhancement. The characteristics of the clusters resulted mainly from the relationship between SIRM/ARM and the S-0.1T, and SIRM/χ and the S-0.1T. Both SIRM/ARM and SIRM/χ increase with increasing S-0.1T values reflecting a greater level of anthropogenic magnetic particles. Overall, data mining methods demonstrated good potential for utilization in environmental magnetism.
Kootenay Lake Fertilization Experiment, Year 15 (North Arm) and Year 3 (South Arm) (2006) Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schindler, E.U.; Sebastian, D.; Andrusak, G.F.
2009-07-01
This report summarizes results from the fifteenth year (2006) of nutrient additions to the North Arm of Kootenay Lake and three years of nutrient additions to the South Arm. Experimental fertilization of the lake has been conducted using an adaptive management approach in an effort to restore lake productivity lost as a result of nutrient uptake in upstream reservoirs. The primary objective of the experiment is to restore kokanee (Oncorhynchus nerka) populations, which are the main food source for Gerrard rainbow trout (Oncorhynchus mykiss) and bull trout (Salvelinus confluentus). The quantity of agricultural grade liquid fertilizer (10-34-0, ammonium polyphosphate andmore » 28-0-0, urea ammonium nitrate) added to the North Arm in 2006 was 44.7 tonnes of P and 248.4 tonnes of N. The total fertilizer load added to the South Arm was 257 tonnes of nitrogen; no P was added. Kootenay Lake has an area of 395 km{sup 2}, a maximum depth of 150 m, a mean depth of 94 m, and a water renewal time of approximately two years. Kootenay Lake is a monomictic lake, generally mixing from late fall to early spring and stratifying during the summer. Surface water temperatures generally exceed 20 C for only a few weeks in July. Results of oxygen profiles were similar to previous years with the lake being well oxygenated from the surface to the bottom depths at all stations. Similar to past years, Secchi disc measurements at all stations in 2006 indicate a typical seasonal pattern of decreasing depths associated with the spring phytoplankton bloom, followed by increasing depths as the bloom gradually decreases by the late summer and fall. Total phosphorus (TP) ranged from 2-7 {micro}g/L and tended to decrease as summer advanced. Over the sampling season dissolved inorganic nitrogen (DIN) concentrations decreased, with the decline corresponding to nitrate (the dominant component of DIN) being utilized by phytoplankton during summer stratification. Owing to the importance of epilimnetic nitrate that is required for optimal phytoplankton growth discrete depth water sampling occurred in 2006 to measure more accurately changes in the nitrate concentrations. As expected there was a seasonal decline in nitrate concentrations, thus supporting the strategy of increasing the nitrogen loading in both arms. These in-season changes emphasize the need for an adaptive management approach to ensure the nitrogen to phosphorus (N:P) ratio does not decrease below 15:1 (weight:weight) during the fertilizer application period. Phytoplankton composition determined from the integrated samples (0-20m) was dominated by diatoms, followed by cryptophytes and chrysophytes. The contribution of cryptophytes to total biomass was higher in 2006 than in 2005. Cryptophytes, considered being edible biomass for zooplankton and Daphnia spp., increased in 2006. Phytoplankton in the discrete depth samples (2, 5, 10, 15 and 20m) demonstrated a clear north to south gradient in average phytoplankton density and biomass among the three stations sampled, with highest values at the North Arm station (KLF 2) and lowest values in the most southern station in the South Arm (KLF 7). Populations were dominated by flagellates at all stations and depths in June and July, then dominated by diatoms in August and September in the North and South arms of the lake. There were no large bluegreen (cyanobacteria) populations in either arm of the lake in 2006. Seasonal average zooplankton abundance and biomass in both the main body of the lake and in the West Arm increased in 2006 compared to 2005. Zooplankton density was numerically dominated by copepods and biomass was dominated by Daphnia spp. The annual average mysid biomass data at deep stations indicated that the North Arm of Kootenay Lake was more productive than the South Arm in 2006. Mysid densities increased through the summer and declined in the winter; mean whole lake values remain within prefertilization densities. Kokanee escapement to Meadow Creek declined in 2006 to approximately 400,000 spawners. The Lardeau River escapement also declined with approximately 100,000 spawners. Escapement in the South Arm tributaries in 2006 was similar to 2005 with virtually no spawners. The mean size of female and male kokanee from Meadow Creek was larger than the past three years (24.9 cm and 25.2 cm, respectively) and larger than the long term average (25.2 cm). This is indicative of a density dependent growth response as a decline in in-lake abundance and returning spawners occurred. Spring hydroacoustic estimates indicated low densities of South Arm kokanee with most of the North Arm fry remaining at the most northerly stations. By the fall, the distribution of kokanee from the North Arm to the South Arm was fairly uniform, a normal occurrence in Kootenay Lake. Fall hydroacoustic estimates in 2006 increased to approximately 22 million kokanee.« less
Health State Utilities Associated with Glucose Monitoring Devices.
Matza, Louis S; Stewart, Katie D; Davies, Evan W; Hellmund, Richard; Polonsky, William H; Kerr, David
2017-03-01
Glucose monitoring is important for patients with diabetes treated with insulin. Conventional glucose monitoring requires a blood sample, typically obtained by pricking the finger. A new sensor-based system called "flash glucose monitoring" monitors glucose levels with a sensor worn on the arm, without requiring blood samples. To estimate the utility difference between these two glucose monitoring approaches for use in cost-utility models. In time trade-off interviews, general population participants in the United Kingdom (London and Edinburgh) valued health states that were drafted and refined on the basis of literature, clinician input, and a pilot study. The health states had identical descriptions of diabetes and insulin treatment, differing only in glucose monitoring approach. A total of 209 participants completed the interviews (51.7% women; mean age = 42.1 years). Mean utilities were 0.851 ± 0.140 for conventional monitoring and 0.882 ± 0.121 for flash monitoring (significant difference between the mean utilities; t = 8.3; P < 0.0001). Of the 209 participants, 78 (37.3%) had a higher utility for flash monitoring, 2 (1.0%) had a higher utility for conventional monitoring, and 129 (61.7%) had the same utility for both health states. The flash glucose monitoring system was associated with a significantly greater utility than the conventional monitoring system. This difference may be useful in cost-utility models comparing the value of glucose monitoring devices for patients with diabetes. This study adds to the literature on treatment process utilities, suggesting that time trade-off methods may be used to quantify preferences among medical devices. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
Analysis of behavioral asymmetries in the elevated plus-maze and in the T-maze.
Schwarting, Rainer K W; Borta, Andreas
2005-02-15
When studying functional asymmetries in normal laboratory rats, several behavioral tests have been applied and proven their utility, including turning in rotometers or open-fields, handedness in paw usage, T-maze alternation, and others. Here, we analyzed male Wistar rats in two tests, namely the elevated plus-maze and the T-maze. In these tests, behavioral asymmetries are rather likely to occur, since the animals have to show several types of turns towards the left or right when ambulating through these environments. In a first study using the plus-maze, we provide detailed data on (A) the types of turns which the animals showed when changing their direction within arms (i.e., 180 degrees turns), and (B) the types of turns when proceeding from one arm to an adjacent one (i.e., 90 degrees turns). With respect to asymmetry, we found moderate biases in favor of the right. On the 1st day of plus-maze testing, there was a trend for more rightward turns within arms. On the 2nd day of testing, there was a trend for turns towards the right when alternating between arms of the plus-maze. In a 2nd study, we asked for asymmetries in the plus-maze in animals, which had been treated acutely with the psychostimulatory amphetamine analogue 3,4-methylene-dioxymethamphetamine (MDMA). Psychostimulants drugs, especially amphetamine, have repeatedly been used before in work on functional asymmetry, since they can enhance or reveal asymmetries in normal rats. MDMA had dose-dependent effects on activity, which affected turns within arms, and turns between arms; however, there was only sparse evidence with respect to asymmetry. Interestingly, and if at all, asymmetry was in favor of the right. Finally, we present data for behavior in the T-maze, where we used a spontaneous test version, that is, the animals could explore the maze but had no task to solve. Asymmetries were measured as turns within the start arm (180 degrees), and as left- or rightward turns between arms (90 degrees ) at the T-point of the maze. In both measures, we again obtained evidence for asymmetries in favor of the right. This work supports previous studies showing that the T-maze is suitable to analyze behavioral asymmetries in rats. In addition, it provides new evidence with respect to the elevated plus-maze, indicating that this standard tool of anxiety research may also be useful in research on behavioral asymmetries and their underlying brain mechanisms. Behavioral biases in favor of the right, as shown here, have often been reported before, especially with Wistar rats. Such biases should be taken into account, since they can serve as an approach to study brain/behavior relationships, and since they may affect the outcome of physiological manipulations or behavioral trainings.
Fuzzy logic applications to expert systems and control
NASA Technical Reports Server (NTRS)
Lea, Robert N.; Jani, Yashvant
1991-01-01
A considerable amount of work on the development of fuzzy logic algorithms and application to space related control problems has been done at the Johnson Space Center (JSC) over the past few years. Particularly, guidance control systems for space vehicles during proximity operations, learning systems utilizing neural networks, control of data processing during rendezvous navigation, collision avoidance algorithms, camera tracking controllers, and tether controllers have been developed utilizing fuzzy logic technology. Several other areas in which fuzzy sets and related concepts are being considered at JSC are diagnostic systems, control of robot arms, pattern recognition, and image processing. It has become evident, based on the commercial applications of fuzzy technology in Japan and China during the last few years, that this technology should be exploited by the government as well as private industry for energy savings.
Technology initiatives with government/business overlap
NASA Astrophysics Data System (ADS)
Knapp, Robert H., Jr.
2015-03-01
Three important present-day technology development settings involve significant overlap between government and private sectors. The Advanced Research Project Agency for Energy (ARPA-E) supports a wide range of "high risk, high return" projects carried out in academic, non-profit or private business settings. The Materials Genome Initiative (MGI), based in the White House, aims at radical acceleration of the development process for advanced materials. California public utilities such as Pacific Gas & Electric operate under a structure of financial returns and political program mandates that make them arms of public policy as much as independent businesses.
2016-02-16
34God is great" and armed with guns and throwing grenades stormed into the Radisson Blue Hotel in Mali’s capital Friday morning and seized 170...capacity building programs as well. Nigerian police, customs officials, and immigration officers participated in interagency training to build their...power provides immediate satisfaction and may be required at times, do we as a nation have the wear-with-all to go the long, hard route and maintain
1970-01-01
Managed by Marshall Space Flight Center, the Space Tug concept was intended to be a reusable multipurpose space vehicle designed to transport payloads to different orbital inclinations. Utilizing mission-specific combinations of its three primary modules (crew, propulsion, and cargo) and a variety of supplementary kits, the Space Tug would have been capable of numerous space applications. This 1970 illustration depicts the primary modules of the Space Tug system along with some of the supplementary kits: lunar landing legs, extendable support arms, astrionics, and the satellite probe. The Space Tug program was cancelled and did not become a reality.
2001-04-03
Corps doctrine. This made clear to me iii the danger of concentrating on emerging technology during doctrine development, while simultaneously de ...is, but introduces his work as an "inquiry" ( historia ). Herodotus clearly believes in the intervention of the gods in his description of historical...He begins the war as a general in the Athenian armed forces. During the eighth year of the war, the Spartan commander, Brasidas, gains access to the
2016-09-01
an instituted safety program that utilizes a generic risk assessment method involving the 5-M (Mission, Man, Machine , Medium and Management) factor...the Safety core value is hinged upon three key principles—(1) each soldier has a crucial part to play, by adopting safety as a core value and making...it a way of life in his unit; (2) safety is an integral part of training, operations and mission success, and (3) safety is an individual, team and
Review of neutron-based technologies for the inspection of cargo containers
NASA Astrophysics Data System (ADS)
Khan, Siraj M.
1994-10-01
Three techniques (API, PFNA and PFTNA) are described and compared in this brief review of neutron based technologies for the detection of contraband in cargo containers. It appears that the role that these techniques can play in the detection of contraband in Customs, airline security and physical security applications remains to be demonstrated. However, their utilization in the fields of non-proliferation, arms control and disarmament, radwaste remediation and pollution control seems more straight forward since the issues of thruput and radiation safety are not so critical.
Tomko, Catherine; Davis, Kimberly M; Luta, George; Krist, Alexander H; Woolf, Steven H; Taylor, Kathryn L
2015-01-01
Patient decision aids facilitate informed decision making for medical tests and procedures that have uncertain benefits. To describe participants' evaluation and utilization of print-based and web-based prostate cancer screening decision aids that were found to improve decisional outcomes in a prior randomized controlled trial. Men completed brief telephone interviews at baseline, one month, and 13 months post-randomization. Participants were primary care patients, 45-70 years old, who received the print-based (N = 628) or web-based decision aid (N = 625) and completed the follow-up assessments. We assessed men's baseline preference for web-based or print-based materials, time spent using the decision aids, comprehension of the overall message, and ratings of the content. Decision aid use was self-reported by 64.3 % (web) and 81.8 % (print) of participants. Significant predictors of decision aid use were race (white vs. non-white, OR = 2.43, 95 % CI: 1.77, 3.35), higher education (OR = 1.68, 95 % CI: 1.06, 2.70) and trial arm (print vs. web, OR = 2.78, 95 % CI: 2.03, 3.83). Multivariable analyses indicated that web-arm participants were more likely to use the website when they preferred web-based materials (OR: 1.91, CI: 1.17, 3.12), whereas use of the print materials was not significantly impacted by a preference for print-based materials (OR: 0.69, CI: 0.38, 1.25). Comprehension of the decision aid message (i.e., screening is an individual decision) did not significantly differ between arms in adjusted analyses (print: 61.9 % and web: 68.2 %, p = 0.42). Decision aid use was independently influenced by race, education, and the decision aid medium, findings consistent with the 'digital divide.' These results suggest that when it is not possible to provide this age cohort with their preferred decision aid medium, print materials will be more highly used than web-based materials. Although there are many advantages to web-based decision aids, providing an option for print-based decision aids should be considered.
NASA Astrophysics Data System (ADS)
McGann, Christopher Leland
Technological progress in the life sciences and engineering has combined with important insights in the fields of biology and material science to make possible the development of biological substitutes which aim to restore function to damaged tissue. Numerous biomimetic hydrogels have been developed with the purpose of harnessing the regenerative capacity of cells and tissue through the rational deployment of biological signals. Aided by recombinant DNA technology and protein engineering methods, a new class of hydrogel precursor, the biosynthetic protein polymer, has demonstrated great promise towards the development of highly functional tissue engineering materials. In particular, protein polymers based upon resilin, a natural protein elastomer, have demonstrated outstanding mechanical properties that would have great value in soft tissue applications. This dissertation introduces hybrid hydrogels composed of recombinant resilin-like polypeptides (RLPs) cross-linked with multi-arm PEG macromers. Two different chemical strategies were employed to form RLP-PEG hydrogels: one utilized a Michael-type addition reaction between the thiols of cysteine residues present within the RLP and vinyl sulfone moieties functionalized on a multi-arm PEG macromer; the second system cross-links a norbornene-functionalized RLP with a thiol-functionalized multi-arm PEG macromer via a photoinitiated thiol-ene step polymerization. Oscillatory rheology and tensile testing confirmed the formation of elastic, resilient hydrogels in the RLP-PEG system cross-linked via Michael-type addition. These hydrogels supported the encapsulation and culture of both human aortic adventitial fibroblasts and human mesenchymal stem cells. Additionally, these RLP-PEG hydrogels exhibited phase separation behavior during cross-linking that led to the formation of a heterogeneous microstructure. Degradation could be triggered through incubation with matrix metalloproteinase. Photocross-linking was conferred to RLPs through the successful conjugation of norbornene acid to the protein. Oscillatory rheology characterized the gelation and subsequent mechanical properties of the photoreactive RLP-PEG hydrogels while the cytocompatibility was confirmed via the successful encapsulation and culture of human mesenchymal stem cells. Both strategies demonstrate the utility of hybrid materials that combine biosynthetic proteins with synthetic polymers. As resilient and cytocompatible materials, RLP-PEG hybrid hydrogels offer an exciting strategy towards the development of biomimetic tissue engineering scaffolds for mechanically-demanding applications.
Proprioceptive Interaction between the Two Arms in a Single-Arm Pointing Task.
Kigawa, Kazuyoshi; Izumizaki, Masahiko; Tsukada, Setsuro; Hakuta, Naoyuki
2015-01-01
Proprioceptive signals coming from both arms are used to determine the perceived position of one arm in a two-arm matching task. Here, we examined whether the perceived position of one arm is affected by proprioceptive signals from the other arm in a one-arm pointing task in which participants specified the perceived position of an unseen reference arm with an indicator paddle. Both arms were hidden from the participant's view throughout the study. In Experiment 1, with both arms placed in front of the body, the participants received 70-80 Hz vibration to the elbow flexors of the reference arm (= right arm) to induce the illusion of elbow extension. This extension illusion was compared with that when the left arm elbow flexors were vibrated or not. The degree of the vibration-induced extension illusion of the right arm was reduced in the presence of left arm vibration. In Experiment 2, we found that this kinesthetic interaction between the two arms did not occur when the left arm was vibrated in an abducted position. In Experiment 3, the vibration-induced extension illusion of one arm was fully developed when this arm was placed at an abducted position, indicating that the brain receives increased proprioceptive input from a vibrated arm even if the arm was abducted. Our results suggest that proprioceptive interaction between the two arms occurs in a one-arm pointing task when the two arms are aligned with one another. The position sense of one arm measured using a pointer appears to include the influences of incoming information from the other arm when both arms were placed in front of the body and parallel to one another.
Proprioceptive Interaction between the Two Arms in a Single-Arm Pointing Task
Kigawa, Kazuyoshi; Izumizaki, Masahiko; Tsukada, Setsuro; Hakuta, Naoyuki
2015-01-01
Proprioceptive signals coming from both arms are used to determine the perceived position of one arm in a two-arm matching task. Here, we examined whether the perceived position of one arm is affected by proprioceptive signals from the other arm in a one-arm pointing task in which participants specified the perceived position of an unseen reference arm with an indicator paddle. Both arms were hidden from the participant’s view throughout the study. In Experiment 1, with both arms placed in front of the body, the participants received 70–80 Hz vibration to the elbow flexors of the reference arm (= right arm) to induce the illusion of elbow extension. This extension illusion was compared with that when the left arm elbow flexors were vibrated or not. The degree of the vibration-induced extension illusion of the right arm was reduced in the presence of left arm vibration. In Experiment 2, we found that this kinesthetic interaction between the two arms did not occur when the left arm was vibrated in an abducted position. In Experiment 3, the vibration-induced extension illusion of one arm was fully developed when this arm was placed at an abducted position, indicating that the brain receives increased proprioceptive input from a vibrated arm even if the arm was abducted. Our results suggest that proprioceptive interaction between the two arms occurs in a one-arm pointing task when the two arms are aligned with one another. The position sense of one arm measured using a pointer appears to include the influences of incoming information from the other arm when both arms were placed in front of the body and parallel to one another. PMID:26317518
Summary of compliant and multi-arm control at NASA. Langley Research Center
NASA Technical Reports Server (NTRS)
Harrison, Fenton W.
1992-01-01
The topics are presented in viewgraph form and include the: single arm system, single arm axis system, single arm control systems, single arm hand controller axis system, single arm position axis system, single arm vision axis system, single arm force axis system, multi-arm system, multi-arm axis system, and the dual arm hand control axis system with control signals.
Farahani, Pendar
2017-05-23
Non-severe hypoglycemia reduces well-being, lowers quality of life, reduces productivity and increases treatment costs. The non-severe hypoglycemia rate, attributable to sulfonylurea (SU) utilization compared with newer classes such as SGLT2-I, could be of clinical significance. To explore the non-severe hypoglycemia risk difference (RD) for SU use compared with SGLT2-I in randomized controlled trials (RCTs) as an add on to metformin. A search was conducted for RCTs of SGLT2-I. PubMed database were utilized for this search. The search was limited to RCTs reported in English language for canagliflozin, dapagliflozin, and empagliflozin. SU dose comparison was utilized to convert the dose of SUs to glimepiride equivalent doses. Totally, 118 RCTs were reviewed; 6 articles had an arm for a SU as add on to metformin. Six articles belong to 3 RCTs, which reported results for 52 weeks and 104 weeks. Average non-severe hypoglycemia rate for SU arm was 30% (5.5%) [Mean (SD)] for 52 weeks and 35.6% (6.1%) for 104 weeks. RD for non-severe hypoglycemia events for SU compared to SGLT2-I was 26.7% (4.9%) for 52 weeks (p-value less than 0.001) and 30.6% (5.5%) for 104 weeks (p-value less than 0.001). There was a significant correlation between dose of SU and hypoglycemia rate (Pearson correlation 0.995; R-square 99%). This study illustrated that a large proportion of patients who had exposure to SU in RCTs of SGLT2-I experienced non-severe hypoglycemia compared to SGLT2-I. There was a close relation between SU dose and increased probability of non-severe hypoglycemia events. © 2017 Journal of Population Therapeutics and Clinical Pharmacology. All rights reserved.
Chirenje, Zvavahera M; Mâsse, Benoît R; Maslankowski, Lisa A; Ramjee, Gita; Coletti, Anne S; Tembo, Tchangani N; Magure, Tsitsi M; Soto-Torres, Lydia; Kelly, Cliff; Hillier, Sharon; Karim, Abdool
2012-01-01
Background The majority of new HIV infections are acquired through heterosexual transmission. There is urgent need for prevention methods to compliment behavior change and condom use. Topical microbicide represent a potential strategy for reduction of HIV transmission in women. Methods Monthly Colposcopy evaluations were performed during pelvic examinations among 299 women enrolled in the Phase 2 portion of HPTN 035 study at four sites (1 in USA, 3 in Southern Africa). This was a phase 2/2b, multisite, randomized, and controlled clinical trial with four arms: BufferGel, 0.5% PRO2000 Gel, placebo gel and no gel. At two of the sites, pelvic examinations were conducted by the use of naked eye without colposcopy. Results A colposcopy finding of any kind was detected in 48% of participants at baseline compared to 40% at 3 months (p =0.04). The lower rates were also observed in vaginal discharge (22% at baseline, 16% at 3 months, p=0.06), erythema (15% at baseline, 8% at 3 months, p=0.004). The trend towards significance at p=0.05 disappear when utilizing stringent statistical significance levels. A pelvic finding of any kind was detected in 71% of colposcopy participants compared to 41% of participants who had naked eye examination only conducted at two sites that performed both colposcopy and naked eye without colposcopy. Use of colposcopy yielded significantly higher rates of participants with deep epithelial disruption, erythema and ecchymosis. We observed no cases of incident Chlamydia, Gonorrhea, or Syphilis during the three month follow up. There were 2 cases of incident HIV during 3-month study period neither of which was associated with any abnormal colposcopy evaluation findings. Conclusion No safety signals were observed in the 4 study arms, allowing seamless transition from phase 2 to 2b. Colposcopy utility in microbicide clinical trials has minimal value given high rates of background noise findings of no relevant clinical significance. PMID:22944480
Chirenje, Zvavahera M; Mâsse, Benoît R; Maslankowski, Lisa A; Ramjee, Gita; Coletti, Anne S; Tembo, Tchangani N; Magure, Tsitsi M; Soto-Torres, Lydia; Kelly, Cliff; Hillier, Sharon; Karim, Abdool
2012-08-27
The majority of new HIV infections are acquired through heterosexual transmission. There is urgent need for prevention methods to compliment behavior change and condom use. Topical microbicide represent a potential strategy for reduction of HIV transmission in women. Monthly Colposcopy evaluations were performed during pelvic examinations among 299 women enrolled in the Phase 2 portion of HPTN 035 study at four sites (1 in USA, 3 in Southern Africa). This was a phase 2/2b, multisite, randomized, and controlled clinical trial with four arms: BufferGel, 0.5% PRO2000 Gel, placebo gel and no gel. At two of the sites, pelvic examinations were conducted by the use of naked eye without colposcopy. A colposcopy finding of any kind was detected in 48% of participants at baseline compared to 40% at 3 months (p =0.04). The lower rates were also observed in vaginal discharge (22% at baseline, 16% at 3 months, p=0.06), erythema (15% at baseline, 8% at 3 months, p=0.004). The trend towards significance at p=0.05 disappear when utilizing stringent statistical significance levels. A pelvic finding of any kind was detected in 71% of colposcopy participants compared to 41% of participants who had naked eye examination only conducted at two sites that performed both colposcopy and naked eye without colposcopy. Use of colposcopy yielded significantly higher rates of participants with deep epithelial disruption, erythema and ecchymosis. We observed no cases of incident Chlamydia, Gonorrhea, or Syphilis during the three month follow up. There were 2 cases of incident HIV during 3-month study period neither of which was associated with any abnormal colposcopy evaluation findings. No safety signals were observed in the 4 study arms, allowing seamless transition from phase 2 to 2b. Colposcopy utility in microbicide clinical trials has minimal value given high rates of background noise findings of no relevant clinical significance.
Caroline, Brammer; Sundus, Yahya; Dawn, Dawson; Carol, Glaister; Susan, Merrick
2016-12-01
The aim of this feasibility study is to define the resource effectiveness of cetuximab vs cisplatin given concomitantly with radiotherapy for squamous cell carcinoma within a National Health Service clinical oncology unit. 20 patients with Stage 3 or 4 head and neck squamous cell cancers were randomized to receive either cetuximab with radiotherapy (ERT) or cisplatin with radiotherapy concurrent with external beam radiotherapy 70 Gy in 35 fractions on a 1 : 1 basis over a 12-month duration. The study compared the resource utilization of ERT vs cisplatin with radiotherapy taking into account drug costs, clinical management and the costs of managing treatment-related toxicity from first fraction of radiotherapy to 6 months after the completion of therapy. Outcome measures were quality of life (recorded at the entry, end of radiotherapy, 6 weeks post treatment and 6 months post treatment), admissions to hospital, delays to radiotherapy, locoregional control and survival. Total drug costs including cost of nutritional supplements for patients treated with cetuximab were £7407.45 compared with £3959.07 for patients treated with cisplatin. Unscheduled admissions for toxicity management were significantly more common in the ERT arm. Healthcare personnel spent significantly more time delivering unscheduled outpatient care for patients receiving cisplatin than for those receiving cetuximab (p = 0.01). No significant difference in the quality of life was suggested at baseline, 6 weeks and 6 months. The mean time to removal of percutaneous gastrostomy (PEG) after completion of radiotherapy was 49.7 weeks in the cisplatin arm and 18.5 weeks in the cetuximab arm (p = 0.04). There was a statistically significant difference in patient-reported use of PEG between the cisplatin and cetuximab arms at 6 months following completion of treatment (p = 0.04). At 21 months, overall survival was 80% in the cisplatin arm vs 50% in the cetuximab (p = 0.332), with disease-free survival being 80% in the cisplatin arm vs 40% in the cetuximab (p = 0.097). Cetuximab is still more expensive in simple drug cost terms than cisplatin when delivered with radiotherapy taking into account costs of drugs for toxicity management and nutritional supplements but other resource implications such as inpatient admission, time spent delivering unscheduled care and cost of additional investigations to manage toxicity for patients treated with cisplatin significantly reduce differential. The study suggested significant differences in patient-reported PEG use at 6 months and in time to PEG removal in favour of the cetuximab arm. Advances in knowledge: There is paucity of randomized data on cost analysis for cisplatin vs cetuximab radiotherapy; this trial informs on the cost analysis between the two approaches.
The Block V Receiver fast acquisition algorithm for the Galileo S-band mission
NASA Technical Reports Server (NTRS)
Aung, M.; Hurd, W. J.; Buu, C. M.; Berner, J. B.; Stephens, S. A.; Gevargiz, J. M.
1994-01-01
A fast acquisition algorithm for the Galileo suppressed carrier, subcarrier, and data symbol signals under low data rate, signal-to-noise ratio (SNR) and high carrier phase-noise conditions has been developed. The algorithm employs a two-arm fast Fourier transform (FFT) method utilizing both the in-phase and quadrature-phase channels of the carrier. The use of both channels results in an improved SNR in the FFT acquisition, enabling the use of a shorter FFT period over which the carrier instability is expected to be less significant. The use of a two-arm FFT also enables subcarrier and symbol acquisition before carrier acquisition. With the subcarrier and symbol loops locked first, the carrier can be acquired from an even shorter FFT period. Two-arm tracking loops are employed to lock the subcarrier and symbol loops parameter modification to achieve the final (high) loop SNR in the shortest time possible. The fast acquisition algorithm is implemented in the Block V Receiver (BVR). This article describes the complete algorithm design, the extensive computer simulation work done for verification of the design and the analysis, implementation issues in the BVR, and the acquisition times of the algorithm. In the expected case of the Galileo spacecraft at Jupiter orbit insertion PD/No equals 14.6 dB-Hz, R(sym) equals 16 symbols per sec, and the predicted acquisition time of the algorithm (to attain a 0.2-dB degradation from each loop to the output symbol SNR) is 38 sec.
Castro-Castro, Julián
2014-01-01
The purpose of this study was to asses the value of intraoperative cone-beam CT (O-arm) and stereotactic navigation for the insertion of anterior odontoid screws. this was a retrospective review of patients receiving surgical treatment for traumatic odontoid fractures during a period of 18 months. Procedures were guided with O-arm assistance in all cases. The screw position was verified with an intraoperative CT scan. Intraoperative and clinical parameters were evaluated. Odontoid fracture fusion was assessed on postoperative CT scans obtained at 3 and 6 months' follow-up Five patients were included in this series; 4 patients (80%) were male. Mean age was 63.6 years (range 35-83 years). All fractures were acute type ii odontoid fractures. The mean operative time was 116minutes (range 60-160minutes). Successful screw placement, judged by intraoperative computed tomography, was attained in all 5 patients (100%). The average preoperative and postoperative times were 8.6 (range 2-22 days) and 4.2 days (range 3-7 days) respectively. No neurological deterioration occurred after surgery. The rate of bone fusion was 80% (4/5). Although this initial study evaluated a small number of patients, anterior odontoid screw fixation utilizing the O-arm appears to be safe and accurate. This system allows immediate CT imaging in the operating room to verify screw position. Copyright © 2014 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.
Generation of “Virtual” Control Groups for Single Arm Prostate Cancer Adjuvant Trials
Koziol, James A.; Chen, Xin; Xia, Xiao-Qin; Wang, Yipeng; Skarecky, Douglas; Sutton, Manuel; Sawyers, Anne; Ruckle, Herbert; Carpenter, Philip M.; Wang-Rodriguez, Jessica; Jiang, Jun; Deng, Mingsen; Pan, Cong; Zhu, Jian-guo; McLaren, Christine E.; Gurley, Michael J.; Lee, Chung; McClelland, Michael; Ahlering, Thomas; Kattan, Michael W.; Mercola, Dan
2014-01-01
It is difficult to construct a control group for trials of adjuvant therapy (Rx) of prostate cancer after radical prostatectomy (RP) due to ethical issues and patient acceptance. We utilized 8 curve-fitting models to estimate the time to 60%, 65%, … 95% chance of progression free survival (PFS) based on the data derived from Kattan post-RP nomogram. The 8 models were systematically applied to a training set of 153 post-RP cases without adjuvant Rx to develop 8 subsets of cases (reference case sets) whose observed PFS times were most accurately predicted by each model. To prepare a virtual control group for a single-arm adjuvant Rx trial, we first select the optimal model for the trial cases based on the minimum weighted Euclidean distance between the trial case set and the reference case set in terms of clinical features, and then compare the virtual PFS times calculated by the optimum model with the observed PFSs of the trial cases by the logrank test. The method was validated using an independent dataset of 155 post-RP patients without adjuvant Rx. We then applied the method to patients on a Phase II trial of adjuvant chemo-hormonal Rx post RP, which indicated that the adjuvant Rx is highly effective in prolonging PFS after RP in patients at high risk for prostate cancer recurrence. The method can accurately generate control groups for single-arm, post-RP adjuvant Rx trials for prostate cancer, facilitating development of new therapeutic strategies. PMID:24465467
Meriggi, Jenna; Parikh, Nidhi; Saad, Kenneth
2016-01-01
Postural corrections of the upper limb are required in tasks ranging from handling an umbrella in the changing wind to securing a wriggling baby. One complication in this process is the mechanical interaction between the different segments of the arm where torque applied at one joint induces motion at multiple joints. Previous studies have shown the long-latency reflexes of shoulder muscles (50–100 ms after a limb perturbation) account for these mechanical interactions by integrating information about motion of both the shoulder and elbow. It is less clear whether long-latency reflexes of elbow muscles exhibit a similar capability and what is the relation between the responses of shoulder and elbow muscles. The present study utilized joint-based loads tailored to the subjects' arm dynamics to induce well-controlled displacements of their shoulder and elbow. Our results demonstrate that the long-latency reflexes of shoulder and elbow muscles integrate motion from both joints: the shoulder and elbow flexors respond to extension at both joints, whereas the shoulder and elbow extensors respond to flexion at both joints. This general pattern accounts for the inherent flexion-extension coupling of the two joints arising from the arm's intersegmental dynamics and is consistent with spindle-based reciprocal excitation of shoulder and elbow flexors, reciprocal excitation of shoulder and elbow extensors, and across-joint inhibition between the flexors and extensors. PMID:26864766
Generation of "virtual" control groups for single arm prostate cancer adjuvant trials.
Jia, Zhenyu; Lilly, Michael B; Koziol, James A; Chen, Xin; Xia, Xiao-Qin; Wang, Yipeng; Skarecky, Douglas; Sutton, Manuel; Sawyers, Anne; Ruckle, Herbert; Carpenter, Philip M; Wang-Rodriguez, Jessica; Jiang, Jun; Deng, Mingsen; Pan, Cong; Zhu, Jian-Guo; McLaren, Christine E; Gurley, Michael J; Lee, Chung; McClelland, Michael; Ahlering, Thomas; Kattan, Michael W; Mercola, Dan
2014-01-01
It is difficult to construct a control group for trials of adjuvant therapy (Rx) of prostate cancer after radical prostatectomy (RP) due to ethical issues and patient acceptance. We utilized 8 curve-fitting models to estimate the time to 60%, 65%, … 95% chance of progression free survival (PFS) based on the data derived from Kattan post-RP nomogram. The 8 models were systematically applied to a training set of 153 post-RP cases without adjuvant Rx to develop 8 subsets of cases (reference case sets) whose observed PFS times were most accurately predicted by each model. To prepare a virtual control group for a single-arm adjuvant Rx trial, we first select the optimal model for the trial cases based on the minimum weighted Euclidean distance between the trial case set and the reference case set in terms of clinical features, and then compare the virtual PFS times calculated by the optimum model with the observed PFSs of the trial cases by the logrank test. The method was validated using an independent dataset of 155 post-RP patients without adjuvant Rx. We then applied the method to patients on a Phase II trial of adjuvant chemo-hormonal Rx post RP, which indicated that the adjuvant Rx is highly effective in prolonging PFS after RP in patients at high risk for prostate cancer recurrence. The method can accurately generate control groups for single-arm, post-RP adjuvant Rx trials for prostate cancer, facilitating development of new therapeutic strategies.
Probabilistic sparse matching for robust 3D/3D fusion in minimally invasive surgery.
Neumann, Dominik; Grbic, Sasa; John, Matthias; Navab, Nassir; Hornegger, Joachim; Ionasec, Razvan
2015-01-01
Classical surgery is being overtaken by minimally invasive and transcatheter procedures. As there is no direct view or access to the affected anatomy, advanced imaging techniques such as 3D C-arm computed tomography (CT) and C-arm fluoroscopy are routinely used in clinical practice for intraoperative guidance. However, due to constraints regarding acquisition time and device configuration, intraoperative modalities have limited soft tissue image quality and reliable assessment of the cardiac anatomy typically requires contrast agent, which is harmful to the patient and requires complex acquisition protocols. We propose a probabilistic sparse matching approach to fuse high-quality preoperative CT images and nongated, noncontrast intraoperative C-arm CT images by utilizing robust machine learning and numerical optimization techniques. Thus, high-quality patient-specific models can be extracted from the preoperative CT and mapped to the intraoperative imaging environment to guide minimally invasive procedures. Extensive quantitative experiments on 95 clinical datasets demonstrate that our model-based fusion approach has an average execution time of 1.56 s, while the accuracy of 5.48 mm between the anchor anatomy in both images lies within expert user confidence intervals. In direct comparison with image-to-image registration based on an open-source state-of-the-art medical imaging library and a recently proposed quasi-global, knowledge-driven multi-modal fusion approach for thoracic-abdominal images, our model-based method exhibits superior performance in terms of registration accuracy and robustness with respect to both target anatomy and anchor anatomy alignment errors.
Dounskaia, Natalia; Shimansky, Yury
2016-06-01
Optimality criteria underlying organization of arm movements are often validated by testing their ability to adequately predict hand trajectories. However, kinematic redundancy of the arm allows production of the same hand trajectory through different joint coordination patterns. We therefore consider movement optimality at the level of joint coordination patterns. A review of studies of multi-joint movement control suggests that a 'trailing' pattern of joint control is consistently observed during which a single ('leading') joint is rotated actively and interaction torque produced by this joint is the primary contributor to the motion of the other ('trailing') joints. A tendency to use the trailing pattern whenever the kinematic redundancy is sufficient and increased utilization of this pattern during skillful movements suggests optimality of the trailing pattern. The goal of this study is to determine the cost function minimization of which predicts the trailing pattern. We show that extensive experimental testing of many known cost functions cannot successfully explain optimality of the trailing pattern. We therefore propose a novel cost function that represents neural effort for joint coordination. That effort is quantified as the cost of neural information processing required for joint coordination. We show that a tendency to reduce this 'neurocomputational' cost predicts the trailing pattern and that the theoretically developed predictions fully agree with the experimental findings on control of multi-joint movements. Implications for future research of the suggested interpretation of the trailing joint control pattern and the theory of joint coordination underlying it are discussed.
Shu, Yi; Haque, Farzin; Shu, Dan; Li, Wei; Zhu, Zhenqi; Kotb, Malak; Lyubchenko, Yuri; Guo, Peixuan
2013-01-01
Due to structural flexibility, RNase sensitivity, and serum instability, RNA nanoparticles with concrete shapes for in vivo application remain challenging to construct. Here we report the construction of 14 RNA nanoparticles with solid shapes for targeting cancers specifically. These RNA nanoparticles were resistant to RNase degradation, stable in serum for >36 h, and stable in vivo after systemic injection. By applying RNA nanotechnology and exemplifying with these 14 RNA nanoparticles, we have established the technology and developed “toolkits” utilizing a variety of principles to construct RNA architectures with diverse shapes and angles. The structure elements of phi29 motor pRNA were utilized for fabrication of dimers, twins, trimers, triplets, tetramers, quadruplets, pentamers, hexamers, heptamers, and other higher-order oligomers, as well as branched diverse architectures via hand-in-hand, foot-to-foot, and arm-on-arm interactions. These novel RNA nanostructures harbor resourceful functionalities for numerous applications in nanotechnology and medicine. It was found that all incorporated functional modules, such as siRNA, ribozymes, aptamers, and other functionalities, folded correctly and functioned independently within the nanoparticles. The incorporation of all functionalities was achieved prior, but not subsequent, to the assembly of the RNA nanoparticles, thus ensuring the production of homogeneous therapeutic nanoparticles. More importantly, upon systemic injection, these RNA nanoparticles targeted cancer exclusively in vivo without accumulation in normal organs and tissues. These findings open a new territory for cancer targeting and treatment. The versatility and diversity in structure and function derived from one biological RNA molecule implies immense potential concealed within the RNA nanotechnology field. PMID:23604636
Huang, Hongtai; Tornero-Velez, Rogelio; Barzyk, Timothy M
2017-11-01
Association rule mining (ARM) has been widely used to identify associations between various entities in many fields. Although some studies have utilized it to analyze the relationship between chemicals and human health effects, fewer have used this technique to identify and quantify associations between environmental and social stressors. Socio-demographic variables were generated based on U.S. Census tract-level income, race/ethnicity population percentage, education level, and age information from the 2010-2014, 5-Year Summary files in the American Community Survey (ACS) database, and chemical variables were generated by utilizing the 2011 National-Scale Air Toxics Assessment (NATA) census tract-level air pollutant exposure concentration data. Six mobile- and industrial-source pollutants were chosen for analysis, including acetaldehyde, benzene, cyanide, particulate matter components of diesel engine emissions (namely, diesel PM), toluene, and 1,3-butadiene. ARM was then applied to quantify and visualize the associations between the chemical and socio-demographic variables. Census tracts with a high percentage of racial/ethnic minorities and populations with low income tended to have higher estimated chemical exposure concentrations (fourth quartile), especially for diesel PM, 1,3-butadiene, and toluene. In contrast, census tracts with an average population age of 40-50 years, a low percentage of racial/ethnic minorities, and moderate-income levels were more likely to have lower estimated chemical exposure concentrations (first quartile). Unsupervised data mining methods can be used to evaluate potential associations between environmental inequalities and social disparities, while providing support in public health decision-making contexts.
2007-09-30
STS123-S-001 (Oct. 2007) --- STS-123 continues assembly of the International Space Station (ISS). The primary mission objectives include rotating an expedition crew member and installing both the first component of the Japanese Experimental Module (the Experimental Logistics Module - Pressurized Section (ELM-PS)) and the Canadian Special Purpose Dexterous Manipulator (SPDM). In addition, STS-123 will deliver various spare ISS components and leave behind the sensor boom used for inspecting the shuttle's thermal protection system. A follow-on mission to ISS will utilize and then return home with this sensor boom. A total of four spacewalks are planned to accomplish these tasks. The mission will also require the use of both the shuttle and ISS robotic arms. STS-123 will utilize the Station-Shuttle Power Transfer System to extend the docked portion of the mission to eleven days, with a total planned duration of 15 days. The crew patch depicts the space shuttle in orbit with the crew names trailing behind. STS-123's major additions to ISS (the ELM-PS installation with the shuttle robotic arm and the fully constructed SPDM) are both illustrated. The ISS is shown in the configuration that the STS-123 crew will encounter when they arrive. The NASA insignia design for space shuttle flights is reserved for use by the astronauts and for other official use as the NASA Administrator may authorize. Public availability has been approved only in the forms of illustrations by the various news media. When and if there is any change in this policy, which is not anticipated, the change will be publicly announced. Photo credit: NASA
2007-10-01
JOHNSON SPACE CENTER, HOUSTON -- STS123-S-001-- STS-123 continues assembly of the International Space Station (ISS). The primary mission objectives include rotating an expedition crew member and installing both the first component of the Japanese Experimental Module (the Experimental Logistics Module - Pressurized Section [ELM-PS]) and the Canadian Special Purpose Dexterous Manipulator (SPDM). In addition, STS-123 will deliver various spare ISS components and leave behind the sensor boom used for inspecting the shuttle's thermal protection system. A follow-on mission to ISS will utilize and then return home with this sensor boom. A total of four spacewalks are planned to accomplish these tasks. The mission will also require the use of both the shuttle and ISS robotic arms. STS-123 will utilize the Station-Shuttle Power Transfer System to extend the docked portion of the mission to 11 days, with a total planned duration of 15 days. The crew patch depicts the space shuttle in orbit with the crew names trailing behind. STS-123's major additions to ISS (the ELM-PS installation with the shuttle robotic arm and the fully constructed SPDM) are both illustrated. The ISS is shown in the configuration that the STS-123 crew will encounter when they arrive. The NASA insignia design for shuttle flights is reserved for use by the astronauts and for other official use as the NASA Administrator may authorize. Public availability has been approved only in the form of illustrations by the various news media. When and if there is any change in this policy, which is not anticipated, it will be publicly announced.
NASA's asteroid redirect mission: Robotic boulder capture option
NASA Astrophysics Data System (ADS)
Abell, P.; Nuth, J.; Mazanek, D.; Merrill, R.; Reeves, D.; Naasz, B.
2014-07-01
NASA is examining two options for the Asteroid Redirect Mission (ARM), which will return asteroid material to a Lunar Distant Retrograde Orbit (LDRO) using a robotic solar-electric-propulsion spacecraft, called the Asteroid Redirect Vehicle (ARV). Once the ARV places the asteroid material into the LDRO, a piloted mission will rendezvous and dock with the ARV. After docking, astronauts will conduct two extravehicular activities (EVAs) to inspect and sample the asteroid material before returning to Earth. One option involves capturing an entire small (˜4--10 m diameter) near-Earth asteroid (NEA) inside a large inflatable bag. However, NASA is also examining another option that entails retrieving a boulder (˜1--5 m) via robotic manipulators from the surface of a larger (˜100+ m) pre-characterized NEA. The Robotic Boulder Capture (RBC) option can leverage robotic mission data to help ensure success by targeting previously (or soon to be) well-characterized NEAs. For example, the data from the Japan Aerospace Exploration Agency's (JAXA) Hayabusa mission has been utilized to develop detailed mission designs that assess options and risks associated with proximity and surface operations. Hayabusa's target NEA, Itokawa, has been identified as a valid target and is known to possess hundreds of appropriately sized boulders on its surface. Further robotic characterization of additional NEAs (e.g., Bennu and 1999 JU_3) by NASA's OSIRIS REx and JAXA's Hayabusa 2 missions is planned to begin in 2018. This ARM option reduces mission risk and provides increased benefits for science, human exploration, resource utilization, and planetary defense.
A Smart DNA Tweezer for Detection of Human Telomerase Activity.
Xu, Xiaowen; Wang, Lei; Li, Kan; Huang, Qihong; Jiang, Wei
2018-03-06
Reliable and accurate detection of telomerase activity is crucial to better understand its role in cancer cells and to further explore its function in cancer diagnosis and treatment. Here, we construct a smart DNA tweezer (DT) for detection of telomerase activity. The DT is assembled by three specially designed single-stranded oligonucleotides: a central strand dually labeled with donor/acceptor fluorophores and two arm strands containing overhangs complementary to telomerase reaction products (TRPs). It can get closed through hybridization with TRPs and get reopen through strand displacement reaction by TRPs' complementary sequences. First, under the action of telomerase, telomerase binding substrates (TS) are elongated to generate TRPs ended with telomeric repeats (TTAGGG) n . TRPs hybridize with the two arm overhangs cooperatively and strain DT to closed state, inducing an increased fluorescence resonance energy transfer (FRET) efficiency, which is utilized for telomerase activity detection. Second, upon introduction of a removal strand (RS) complementary to TRPs, the closed DT is relaxed to open state via the toehold-mediated strand displacement, inducing a decreased FRET efficiency, which is utilized for determination of TRP length distribution. The detection limit of telomerase activity is equivalent to 141 cells/μL for HeLa cells, and telomerase-active cellular extracts can be differentiated from telomerase-inactive cellular extracts. Furthermore, TRPs owning 1, 2, 3, 4, and ≥5 telomeric repeats are identified to account for 25.6%, 20.5%, 15.7%, 12.5%, and 25.7%, respectively. The proposed strategy will offer a new approach for reliable, accurate detection of telomerase activity and product length distribution for deeper studying its role and function in cancer.
Integrated optical gyroscopes offering low cost, small size and vibration immunity
NASA Astrophysics Data System (ADS)
Monovoukas, Christos; Swiecki, Andrew; Maseeh, Fariborz
2000-03-01
IntelliSense has developed an integrated optic gyro technology that provides the sensitivity of fiber optic gyros while utilizing batch microfabrication techniques to achieve the low cost of mechanical MEMS gyros. The base technology consists of an optical resonating waveguide chip, sensor electronics and an optical bench. The sensing element is based on an integrated optic waveguide chip in which counter-propagating optical fields are used to sense rotation in the plane of the waveguide through the Sagnac effect. It is powered by a semiconductor laser light source, which is coupled into a waveguide and split into two waveguide arms. Both signals are probed through the out coupled light at each waveguide arm, and rate information is derived from the difference in phase between these two signals. Measuring angular rotation is important for proper operation of a variety of systems such as: missile guidance systems, satellites, energy exploration, camera stabilization, robotics positioning, platform stabilization and space craft guidance to mention a few. This technology overcomes the limitations that previous commercially available gyros for this purpose have had including limitations in size, sensitivity, durability, and premium price.
Negotiation from weakness: Concept, model, and application to strategic negotiations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tangredi, S.J.
Analysis of the dynamics of asymmetrical negotiations requires the development of the novel concept of negotiation from weakness. A nation is assumed to be negotiating from weakness when the elements of national power place it at a relative disadvantage in achieving the desired objectives of a particular set of negotiations. Successful negotiation from weakness is the adoption and application of negotiating strategies and tactics (subjective elements) that nullify the possible effects of an asymmetry in objective power potential. Once developed, the model is applied to arms control negotiations between the United States and Soviet Union in 1962-1972, a period inmore » which the United States was assumed to be strategically superior. Outcomes of the arms control negotiations examined suggests that the Soviet Union attempted to utilize strategies and tactics appropriate to the negotiating from weakness situation. The success of the Soviet Union is reversing the perceived strategic balance by 1972, implies that the concept of successful negotiating from weakness is a viable approach to the examination of asymmetrical negotiations involving security issues.« less
Byrne, Gerard D; Vllasaliu, Driton; Falcone, Franco H; Somekh, Michael G; Stolnik, Snjezana
2015-11-02
In this work we utilize the combination of label-free total internal reflection microscopy and total internal reflectance fluorescence (TIRM/TIRF) microscopy to achieve a simultaneous, live imaging of single, label-free colloidal particle endocytosis by individual cells. The TIRM arm of the microscope enables label free imaging of the colloid and cell membrane features, while the TIRF arm images the dynamics of fluorescent-labeled clathrin (protein involved in endocytosis via clathrin pathway), expressed in transfected 3T3 fibroblasts cells. Using a model polymeric colloid and cells with a fluorescently tagged clathrin endocytosis pathway, we demonstrate that wide field TIRM/TIRF coimaging enables live visualization of the process of colloidal particle interaction with the labeled cell structure, which is valuable for discerning the membrane events and route of colloid internalization by the cell. We further show that 500 nm in diameter model polystyrene colloid associates with clathrin, prior to and during its cellular internalization. This association is not apparent with larger, 1 μm in diameter colloids, indicating an upper particle size limit for clathrin-mediated endocytosis.
Type III CRISPR-Cas systems can provide redundancy to counteract viral escape from type I systems
Silas, Sukrit; Lucas-Elio, Patricia; Jackson, Simon A; Aroca-Crevillén, Alejandra; Hansen, Loren L; Fineran, Peter C
2017-01-01
CRISPR-Cas-mediated defense utilizes information stored as spacers in CRISPR arrays to defend against genetic invaders. We define the mode of target interference and role in antiviral defense for two CRISPR-Cas systems in Marinomonas mediterranea. One system (type I-F) targets DNA. A second system (type III-B) is broadly capable of acquiring spacers in either orientation from RNA and DNA, and exhibits transcription-dependent DNA interference. Examining resistance to phages isolated from Mediterranean seagrass meadows, we found that the type III-B machinery co-opts type I-F CRISPR-RNAs. Sequencing and infectivity assessments of related bacterial and phage strains suggests an ‘arms race’ in which phage escape from the type I-F system can be overcome through use of type I-F spacers by a horizontally-acquired type III-B system. We propose that the phage-host arms race can drive selection for horizontal uptake and maintenance of promiscuous type III interference modules that supplement existing host type I CRISPR-Cas systems. PMID:28826484
Towe, Sheri L; Patel, Puja; Meade, Christina S
HIV-associated neurocognitive impairments that impact daily function persist in the era of effective antiretroviral therapy. Cognitive training, a promising low-cost intervention, has been shown to improve neurocognitive functioning in some clinical populations. We tested the feasibility, acceptability, and preliminary effects of computerized cognitive training to improve working memory in persons living with HIV infection (PLWH) and working memory impairment. In this randomized clinical trial, we assigned 21 adult PLWH to either an experimental cognitive training intervention or an attention-matched control training intervention. Participants completed 12 training sessions across 10 weeks with assessments at baseline and post-training. Session attendance was excellent and participants rated the program positively. Participants in the experimental arm demonstrated improved working memory function over time; participants in the control arm showed no change. Our results suggest that cognitive training may be a promising intervention for working memory impairment in PLWH and should be evaluated further. Copyright © 2017 Association of Nurses in AIDS Care. Published by Elsevier Inc. All rights reserved.
New Paradigm for Translational Modeling to Predict Long‐term Tuberculosis Treatment Response
Bartelink, IH; Zhang, N; Keizer, RJ; Strydom, N; Converse, PJ; Dooley, KE; Nuermberger, EL
2017-01-01
Abstract Disappointing results of recent tuberculosis chemotherapy trials suggest that knowledge gained from preclinical investigations was not utilized to maximal effect. A mouse‐to‐human translational pharmacokinetics (PKs) – pharmacodynamics (PDs) model built on a rich mouse database may improve clinical trial outcome predictions. The model included Mycobacterium tuberculosis growth function in mice, adaptive immune response effect on bacterial growth, relationships among moxifloxacin, rifapentine, and rifampin concentrations accelerating bacterial death, clinical PK data, species‐specific protein binding, drug‐drug interactions, and patient‐specific pathology. Simulations of recent trials testing 4‐month regimens predicted 65% (95% confidence interval [CI], 55–74) relapse‐free patients vs. 80% observed in the REMox‐TB trial, and 79% (95% CI, 72–87) vs. 82% observed in the Rifaquin trial. Simulation of 6‐month regimens predicted 97% (95% CI, 93–99) vs. 92% and 95% observed in 2RHZE/4RH control arms, and 100% predicted and observed in the 35 mg/kg rifampin arm of PanACEA MAMS. These results suggest that the model can inform regimen optimization and predict outcomes of ongoing trials. PMID:28561946
Rogers, Amy E; Stahlman, Shauna; Hunt, Devin J; Oh, Gi-Taik; Clark, Leslie L
2016-10-01
Obstructive sleep apnea (OSA) is a growing health concern in both civilian and military populations. Individuals who suffer from OSA have increased rates of cardiovascular disease, chronic fatigue, motor vehicle accidents, cognitive impairment, and post-traumatic stress disorder. Data from the Defense Medical Surveillance System (DMSS) were utilized to examine the incidence of OSA and associated attrition from service in active component military members from 1 January 2004 through 31 May 2016. The study identified 223,731 incident cases of OSA with an overall incidence rate of 139.2 per 10,000 person-years, between 2004 and 2015. Rates increased more than 3-fold between 2004 and 2015. In 2015, 48.1% of all incident cases of OSA were diagnosed in the last year of service. The high percentage of cases diagnosed prior to separation from service is concerning because OSA is a treatable and partially preventable disease. OSA represents a large health and economic burden for the armed services and yet there are persistent research gaps in appropriate screening and prevention strategies to improve both individual health and mission performance.
Contextual Multi-armed Bandits under Feature Uncertainty
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yun, Seyoung; Nam, Jun Hyun; Mo, Sangwoo
We study contextual multi-armed bandit problems under linear realizability on rewards and uncertainty (or noise) on features. For the case of identical noise on features across actions, we propose an algorithm, coined NLinRel, having O(T⁷/₈(log(dT)+K√d)) regret bound for T rounds, K actions, and d-dimensional feature vectors. Next, for the case of non-identical noise, we observe that popular linear hypotheses including NLinRel are impossible to achieve such sub-linear regret. Instead, under assumption of Gaussian feature vectors, we prove that a greedy algorithm has O(T²/₃√log d)regret bound with respect to the optimal linear hypothesis. Utilizing our theoretical understanding on the Gaussian case,more » we also design a practical variant of NLinRel, coined Universal-NLinRel, for arbitrary feature distributions. It first runs NLinRel for finding the ‘true’ coefficient vector using feature uncertainties and then adjust it to minimize its regret using the statistical feature information. We justify the performance of Universal-NLinRel on both synthetic and real-world datasets.« less
Kansal-Kalra, Suleena; Milad, Magdy P; Grobman, William A
2005-09-01
To compare the economic consequences of proceeding directly to IVF to those of proceeding with gonadotropins followed by IVF in patients <35 years of age with unexplained infertility. A decision-tree model. The model incorporated the cost and success of each infertility regimen as well as the pregnancy-associated costs of singleton or multiple gestations and the risk and cost of cerebral palsy. Cost per live birth. Both treatment arms resulted in a >80% chance of birth. The gonadotropin arm was over four times more likely to result in a high-order multiple pregnancy (HOMP). Despite this, when the base case estimates were utilized, immediate IVF emerged as more costly per live birth. In sensitivity analysis, immediate IVF became less costly per live birth when IVF was more likely to achieve birth (55.1%) or cheaper (11,432 dollars) than our base case assumptions. After considering the risk and cost of HOMP, immediate IVF is more costly per live birth than a trial of gonadotropins prior to IVF.
Evaluation of Sex-Specific Movement Patterns in Judo Using Probabilistic Neural Networks.
Miarka, Bianca; Sterkowicz-Przybycien, Katarzyna; Fukuda, David H
2017-10-01
The purpose of the present study was to create a probabilistic neural network to clarify the understanding of movement patterns in international judo competitions by gender. Analysis of 773 male and 638 female bouts was utilized to identify movements during the approach, gripping, attack (including biomechanical designations), groundwork, defense, and pause phases. Probabilistic neural network and chi-square (χ 2 ) tests modeled and compared frequencies (p ≤ .05). Women (mean [interquartile range]: 9.9 [4; 14]) attacked more than men (7.0 [3; 10]) while attempting a greater number of arm/leg lever (women: 2.7 [1; 6]; men: 4.0 [0; 4]) and trunk/leg lever (women: 0.8 [0; 1]; men: 2.4 [0; 4]) techniques but fewer maximal length-moment arm techniques (women: 0.7 [0; 1]; men: 1.0 [0; 2]). Male athletes displayed one-handed gripping of the back and sleeve, whereas female athletes executed a greater number of groundwork techniques. An optimized probabilistic neural network model, using patterns from the gripping, attack, groundwork, and pause phases, produced an overall prediction accuracy of 76% for discrimination between men and women.
CONTROL OF APERTURE CLOSURE INITIATION DURING TRUNK-ASSISTED REACH-TO-GRASP MOVEMENTS
Rand, Miya K.; Van Gemmert, Arend W. A.; Hossain, Abul B.M.I.; Shimansky, Yury P.; Stelmach, George E.
2012-01-01
The present study investigated how the involvement and direction of trunk movement during reach-to-grasp movements affect the coordination between the transport and grasping components. Seated young adults made prehensile movements in which the involvement of the trunk was varied; the trunk was not involved, moved forward (flexion), or moved backward (extension) in the sagittal plane during the reach to the object. Each of the trunk movements was combined with an extension or flexion motion of the arm during the reach. Regarding the relation between the trunk and arm motion for arm transport, the onset of wrist motion relative to that of the trunk was delayed to a greater extent for the trunk extension than for the trunk flexion. The variability of the time period from the peak of wrist velocity to the peak of trunk velocity was also significantly greater for trunk extension compared to trunk flexion. These findings indicate that trunk flexion was better integrated into the control of wrist transport than trunk extension. In terms of the temporal relationship between wrist transport and grip aperture, the relation between the time of peak wrist velocity and the time of peak grip aperture did not change or became less steady across conditions. Therefore, the stability of temporal coordination between wrist transport and grip aperture was maintained despite the variation of the pattern of intersegmental coordination between the arm and the trunk during arm transport. The transport-aperture coordination was further assessed in terms of the control law according to which the initiation of aperture closure during the reach occurs when the hand crosses a hand-to-target distance threshold for grasp initiation that is a function of peak aperture, wrist velocity and acceleration, trunk velocity and acceleration, and trunk-to-target distance at the time of aperture closure initiation. The participants increased the hand-to-target distance threshold for grasp initiation in the conditions where the trunk was involved compared to the conditions where the trunk was not involved. An increase also occurred when the trunk was extended compared to when it was flexed. The increased distance threshold implies an increase in the hand-to-target distance-related safety margin for grasping when the trunk is involved, especially when it is extended. These results suggest that the CNS significantly utilizes the parameters of trunk movement together with movement parameters related to the arm and the hand for controlling grasp initiation. PMID:22526948
Control of aperture closure initiation during trunk-assisted reach-to-grasp movements.
Rand, Miya K; Van Gemmert, Arend W A; Hossain, Abul B M I; Shimansky, Yury P; Stelmach, George E
2012-06-01
The present study investigated how the involvement and direction of trunk movement during reach-to-grasp movements affect the coordination between the transport and grasping components. Seated young adults made prehensile movements in which the involvement of the trunk was varied; the trunk was not involved, moved forward (flexion), or moved backward (extension) in the sagittal plane during the reach to the object. Each of the trunk movements was combined with an extension or flexion motion of the arm during the reach. Regarding the relationship between the trunk and arm motion for arm transport, the onset of wrist motion relative to that of the trunk was delayed to a greater extent for the trunk extension than for the trunk flexion. The variability of the time period from the peak of wrist velocity to the peak of trunk velocity was also significantly greater for trunk extension compared to trunk flexion. These findings indicate that trunk flexion was better integrated into the control of wrist transport than trunk extension. In terms of the temporal relationship between wrist transport and grip aperture, the relationship between the time of peak wrist velocity and the time of peak grip aperture did not change or become less steady across conditions. Therefore, the stability of temporal coordination between wrist transport and grip aperture was maintained despite the variation of the pattern of intersegmental coordination between the arm and the trunk during arm transport. The transport-aperture coordination was further assessed in terms of the control law according to which the initiation of aperture closure during the reach occurs when the hand crosses a hand-to-target distance threshold for grasp initiation, which is a function of peak aperture, wrist velocity and acceleration, trunk velocity and acceleration, and trunk-to-target distance at the time of aperture closure initiation. The participants increased the hand-to-target distance threshold for grasp initiation in the conditions where the trunk was involved compared to the conditions where the trunk was not involved. An increase also occurred when the trunk was extended compared to when it was flexed. The increased distance threshold implies an increase in the hand-to-target distance-related safety margin for grasping when the trunk is involved, especially when it is extended. These results suggest that the CNS significantly utilizes the parameters of trunk movement together with movement parameters related to the arm and the hand for controlling grasp initiation.
NASA Astrophysics Data System (ADS)
Freeman, J. W.
Aspects of solar power generation in space are considered. The subjects discussed include: a vision of future energy from space; solar power satellite concept for utilization of energy from space; the institutional challenge of solar power satellites; system study of the solar power satellite concept; market potential and possible limitations for satellite solar power stations; financing a solar power satellite project; and European questions related to satellite power systems. Also addressed are: options and high payoff choices for transportation; an electric propulsion transportation system from low-earth orbit to geostationary orbit utilizing beamed microwave power; the Canadarm robot arm of the Shuttle Remote Manipulator System; an early experimental solar power satellite; power economical considerations for the integration of terrestrial and extraterrestrial solar generators into existing power generation stations; and space solar power in perspective. For individual items see A84-21477 to A84-21489
Ren, Jian
2017-01-10
Electro-optic crystals, such as potassium tantalate niobate [KTa1-xNbxO3(KTN)], are enabling materials for many optical devices. Their utility in broadband applications heavily depends on their dispersion property. To this end, an analysis of dispersion mismatch in broadband optical interferometers is first presented. Then a method utilizing polynomial phase fitting to measure the dispersion property of materials composing the arms of an interferometer is introduced. As a demonstration, an interferometry system based on optical coherence tomography (OCT) was built, where, for the first time, the group velocity dispersion of a KTN crystal around 1310 nm was measured and numerically compensated for OCT imaging. Several advantages over a widely used method in OCT, which is based on metric functions, are discussed. The results show the fitting method can provide a more reliable measurement with reduced computation complexity.
Robotic end gripper with a band member to engage object
Pollard, Roy E.; Robinson, Samuel C.; Thompson, William F.; Couture, Scott A.; Sutton, Bill J.
1994-01-01
An end effector for use with robotic arms and like devices that utilizes a flexible band to draw an object against an anvil having a concave surface. One typical convex surface is created by a V-block, with an apex of the V being centrally located. If an object to be grasped is fragile, the contour of the concave surface closely matches the surface of the object. Typically the movement of the band is effected by a linear actuator, with the anvil remaining fixed relative to a support base. Several embodiments are described that utilize variations in drawing the band toward the anvil, with one of these embodiments described in detail in the form of a fabricated unit. One embodiment includes a cover element that can be moved over an object after the grasping thereof, with this cover potentially serving various functions. Movement of the cover can be effected with a second linear actuator.
How do octopuses use their arms?
Mather, J A
1998-09-01
A taxonomy of the movement patterns of the 8 flexible arms of octopuses is constructed. Components consist of movements of the arm itself, the ventral suckers and their stalks, as well as the relative position of arms and the skin web between them. Within 1 arm, combinations of components result in a variety of behaviors. At the level of all arms, 1 group of behaviors is described as postures, on the basis of the spread of all arms and the web to make a 2-dimensional surface whose position differs in the 3rd dimension. Another group of arm behaviors is actions, more or less coordinated and involving several to all arms. Arm control appears to be based on radial symmetry, relative equipotentiality of all arms, relative independence of each arm, and separability of components within the arm. The types and coordination of arm behaviors are discussed with relationship to biomechanical limits, muscle structures, and neuronal programming.
Design of a community-based intergenerational oral health study: "Baby Smiles".
Milgrom, Peter; Riedy, Christine A; Weinstein, Philip; Mancl, Lloyd A; Garson, Gayle; Huebner, Colleen E; Smolen, Darlene; Sutherland, Marilynn
2013-08-06
Rural, low-income pregnant women and their children are at high risk for poor oral health and have low utilization rates of dental care. The Baby Smiles study was designed to increase low-income pregnant women's utilization of dental care, increase young children's dental care utilization, and improve home oral health care practices. Baby Smiles was a five-year, four-site randomized intervention trial with a 2 × 2 factorial design. Four hundred participants were randomly assigned to one of four treatment arms in which they received either brief Motivational Interviewing (MI) or health education (HE) delivered during pregnancy and after the baby was born. In the prenatal study phase, the interventions were designed to encourage dental utilization during pregnancy. After childbirth, the focus was to utilize dental care for the infant by age one. The two primary outcome measures were dental utilization during pregnancy or up to two months postpartum for the mother, and preventive dental utilization by 18 months of age for the child. Medicaid claims data will be used to assess the primary outcomes. Questionnaires were administered at enrollment and 3, 9 and 18 months postpartum (study end) to assess mediating and moderating factors. This trial can help define the most effective way to provide one-on-one counseling to pregnant women and new mothers regarding visits to the dentist during pregnancy and after the child is born. It supports previous work demonstrating the potential of reducing mother-to-child transmission of Streptococcus mutans and the initiation of dental caries prevention in early childhood. ClinicalTrials.gov Identifier NCT01120041.
Methylphenidate improves performance on the radial arm maze in periadolescent rats
Dow-Edwards, Diana L.; Weedon, Jeremy C.; Hellmann, Esther
2008-01-01
Methylphenidate (Ritalin; MPD) is one of the most commonly prescribed drugs in childhood and adolescence and many clinical studies have documented its efficacy. Due to the limitations of conducting invasive research in humans, animal models can be beneficial for studying drug effects. However, few animal studies have demonstrated the effects of methylphenidate on cognitive processes. The objective of this study was to find a dose of methylphenidate that was effective in improving performance on a spatial working memory cognitive task when administered orally to periadolescent rats. Therefore, we dosed subjects with methylphenidate at 1 or 3 mg/kg/day via gastric intubation from postnatal day 22 to 59 and assessed the effects of the drug on performance on the radial arm maze each day. To enhance performance overall, a second experiment was conducted where the subjects were moderately food restricted (to 90% of the free-feeding weight). Results of Experiment 1 show that during the first week of testing only the 3mg/kg MPD-treated males showed improved performance (entries prior to repeated entry) when ad-lib fed and housed in pairs while the same dose significantly improved performance in both males and females under conditions of food-restriction and individual housing in Experiment 2. MPD also produced a pattern of increased errors and arms entered during the first week, especially in Experiment 2. MPD increased locomotor activity when tested at postnatal day 60 in both experiments. The data suggest that 3mg/kg oral methylphenidate improves performance on a spatial cognitive task only early in treatment in the rat. While males show improvement under conditions of both high and low motivation, females only show MPD effects when highly motivated. Hypothetically, methylphenidate may improve radial arm maze performance through increased attention and improved spatial working memory and/or alterations in locomotion, reactivity to novelty or anxiety. Regardless, the study supports the utility of the rat as a suitable model to examine the effects of low dose oral MPD. PMID:18538539
Evaluating Suit Fit Using Performance Degradation
NASA Technical Reports Server (NTRS)
Margerum, Sarah E.; Cowley, Matthew; Harvill, Lauren; Benson, Elizabeth; Rajulu, Sudhakar
2012-01-01
The Mark III planetary technology demonstrator space suit can be tailored to an individual by swapping the modular components of the suit, such as the arms, legs, and gloves, as well as adding or removing sizing inserts in key areas. A method was sought to identify the transition from an ideal suit fit to a bad fit and how to quantify this breakdown using a metric of mobility-based human performance data. To this end, the degradation of the range of motion of the elbow and wrist of the suit as a function of suit sizing modifications was investigated to attempt to improve suit fit. The sizing range tested spanned optimal and poor fit and was adjusted incrementally in order to compare each joint angle across five different sizing configurations. Suited range of motion data were collected using a motion capture system for nine isolated and functional tasks utilizing the elbow and wrist joints. A total of four subjects were tested with motions involving both arms simultaneously as well as the right arm by itself. Findings indicated that no single joint drives the performance of the arm as a function of suit size; instead it is based on the interaction of multiple joints along a limb. To determine a size adjustment range where an individual can operate the suit at an acceptable level, a performance detriment limit was set. This user-selected limit reveals the task-dependent tolerance of the suit fit around optimal size. For example, the isolated joint motion indicated that the suit can deviate from optimal by as little as -0.6 in to -2.6 in before experiencing a 10% performance drop in the wrist or elbow joint. The study identified a preliminary method to quantify the impact of size on performance and developed a new way to gauge tolerances around optimal size.
Koç, Nevra; Gündüz, Mehmet; Tavil, Betül; Azik, M Fatih; Coşkun, Zeynep; Yardımcı, Hülya; Uçkan, Duygu; Tunç, Bahattin
2017-08-01
The aim of this study was to evaluate nutritional status in children who underwent hematopoietic stem cell transplant compared with a healthy control group. A secondary aim was to utilize mid-upper arm circumference as a measure of nutritional status in these groups of children. Our study group included 40 children (18 girls, 22 boys) with mean age of 9.2 ± 4.6 years (range, 2-17 y) who underwent hematopoietic stem cell transplant. Our control group consisted of 20 healthy children (9 girls, 11 boys). The children were evaluated at admission to the hospital and followed regularly 3, 6, 9, and 12 months after discharge from the hospital. In the study group, 27 of 40 patients (67.5%) received nutritional support during hematopoietic stem cell transplant, with 15 patients (56%) receiving enteral nutrition, 6 (22%) receiving total parenteral nutrition, and 6 (22%) receiving enteral and total parenteral nutrition. Chronic malnutrition rate in the study group was 47.5% on admission to the hospital, with the control group having a rate of 20%. One year after transplant, the rate decreased to 20% in the study group and 5% in the control group. The mid-upper arm circumference was lower in children in the study group versus the control group at the beginning of the study (P < .05). However, there were no significant differences in mid-upper arm circumference measurements between groups at follow-up examinations (P > .05). During follow-up, all anthropometric measurements increased significantly in both groups. Monitoring nutritional status and initiating appropriate nutritional support improved the success of hematopoietic stem cell transplant and provided a more comfortable process during the transplant period. Furthermore, mid-upper arm circumference is a more sensitive, useful, and safer parameter that can be used to measure nutritional status of children who undergo hematopoietic stem cell transplant.
Bradbury, Penelope A; Tu, Dongsheng; Seymour, Lesley; Isogai, Pierre K; Zhu, Liting; Ng, Raymond; Mittmann, Nicole; Tsao, Ming-Sound; Evans, William K; Shepherd, Frances A; Leighl, Natasha B
2010-03-03
The NCIC Clinical Trials Group conducted the BR.21 trial, a randomized placebo-controlled trial of erlotinib (an epidermal growth factor receptor tyrosine kinase inhibitor) in patients with previously treated advanced non-small cell lung cancer. This trial accrued patients between August 14, 2001, and January 31, 2003, and found that overall survival and quality of life were improved in the erlotinib arm than in the placebo arm. However, funding restrictions limit access to erlotinib in many countries. We undertook an economic analysis of erlotinib treatment in this trial and explored different molecular and clinical predictors of outcome to determine the cost-effectiveness of treating various populations with erlotinib. Resource utilization was determined from individual patient data in the BR.21 trial database. The trial recruited 731 patients (488 in the erlotinib arm and 243 in the placebo arm). Costs arising from erlotinib treatment, diagnostic tests, outpatient visits, acute hospitalization, adverse events, lung cancer-related concomitant medications, transfusions, and radiation therapy were captured. The incremental cost-effectiveness ratio was calculated as the ratio of incremental cost (in 2007 Canadian dollars) to incremental effectiveness (life-years gained). In exploratory analyses, we evaluated the benefits of treatment in selected subgroups to determine the impact on the incremental cost-effectiveness ratio. The incremental cost-effectiveness ratio for erlotinib treatment in the BR.21 trial population was $94,638 per life-year gained (95% confidence interval = $52,359 to $429,148). The major drivers of cost-effectiveness included the magnitude of survival benefit and erlotinib cost. Subgroup analyses revealed that erlotinib may be more cost-effective in never-smokers or patients with high EGFR gene copy number. With an incremental cost-effectiveness ratio of $94 638 per life-year gained, erlotinib treatment for patients with previously treated advanced non-small cell lung cancer is marginally cost-effective. The use of molecular predictors of benefit for targeted agents may help identify more or less cost-effective subgroups for treatment.
Chay, Wen Yee; Tham, Chee Kian; Toh, Han Chong; Lim, Hwee Yong; Tan, Chee Kiat; Lim, Cindy; Wang, Who-Whong; Choo, Su-Pin
2017-08-01
The majority of patients with hepatocellular carcinoma (HCC) are inoperable and results with conventional chemotherapy are dismal. Many end up with no treatment options and resort to alternative medicine. The authors report the use of Coriolus versicolor (CV) in advanced HCC patients with poor liver function or who were unfit to receive standard therapy. Fifteen eligible cases were randomized 2:1 to either CV or placebo. The primary endpoint was the median time to progression (TTP) between both arms. Secondary endpoints include evaluating response rates, toxicity, quality of life (QOL), progression-free survival (PFS), and overall survival (OS). Further correlative studies were performed looking at the effect of CV on the immune system. The median treatment duration was 1.5 cycles and 3 cycles on the placebo and CV arm, respectively. Median TTP was 2.5 (1.4-5.3) months compared to 4.2 (0.4-4.2) months in the CV and placebo arm, respectively, hazard ratio (HR) 0.70 (0.16-3.05 p = 0.634). Median PFS was 2.5 (1.4-5.3) months in the CV and 1.1 (0.4-4.2) months in the placebo arm, HR 0.42 (0.13-1.34, p = 0.144). Median OS was 6.5 (3.3-24.1) and 2.2 (0.8-23.3) months, respectively, HR 0.35 (0.10-1.25, p = 0.105). Social and emotional functioning scores were higher in the CV group compared to placebo group on treatment. CV subjects had less appetite loss and pain symptoms compared to placebo subjects during treatment. There was no difference in TTP with use of CV compared to placebo. CV subjects generally had better QOL on treatment compared to placebo subjects. The utility of this supplement in patients whose primary treatment goal is palliation should be further explored.
Lodhia, Parth; Gui, Chengcheng; Chandrasekaran, Sivashankar; Suarez-Ahedo, Carlos; Dirschl, Douglas R; Domb, Benjamin G
2016-07-01
Hip arthroscopic surgery has emerged as a successful procedure to manage acetabular labral tears and concurrent hip injuries, which if left untreated, may contribute to hip osteoarthritis (OA). Therefore, it is essential to analyze the economic impact of this treatment option. To investigate the cost-effectiveness of hip arthroscopic surgery versus structured rehabilitation alone for acetabular labral tears, to examine the effects of age on cost-effectiveness, and to estimate the rate of symptomatic OA and total hip arthroplasty (THA) in both treatment arms over a lifetime horizon. Economic and decision analysis; Level of evidence, 2. A cost-effectiveness analysis of hip arthroscopic surgery compared with structured rehabilitation for symptomatic labral tears was performed using a Markov decision model constructed over a lifetime horizon. It was assumed that patients did not have OA. Direct costs (in 2014 United States dollars), utilities of health states (in quality-adjusted life years [QALYs] gained), and probabilities of transitioning between health states were estimated from a comprehensive literature review. Costs were estimated using national averages of Medicare reimbursements, adjusted for all payers in the United States from a societal perspective. Utilities were estimated from the Harris Hip Score. Cost-effectiveness was assessed using the incremental cost-effectiveness ratio (ICER). One-way and probabilistic sensitivity analyses were performed to determine the effect of uncertainty on the model outcomes. For a cohort representative of patients undergoing hip arthroscopic surgery at our facility, arthroscopic surgery was more costly (additional $2653) but generated more utility (additional 3.94 QALYs) compared with rehabilitation over a lifetime. The mean ICER was $754/QALY, well below the conventional willingness to pay of $50,000/QALY. Arthroscopic surgery was cost-effective for 94.5% of patients. Although arthroscopic surgery decreased in cost-effectiveness with increasing age, arthroscopic surgery remained more cost-effective than rehabilitation for patients in the second to seventh decades of life. The lifetime incidence of symptomatic hip OA was over twice as high for patients treated with rehabilitation compared with arthroscopic surgery. The preferred treatment was sensitive to the utility after successful hip arthroscopic surgery, although the utility at which arthroscopic surgery becomes less cost-effective than rehabilitation is far below our best estimate. For older patients, the lifetime cost of arthroscopic surgery was greater, while the lifetime utility of arthroscopic surgery was less, approaching that of the rehabilitation arm. Hip arthroscopic surgery is more cost-effective and results in a considerably lower incidence of symptomatic OA than structured rehabilitation alone in treating symptomatic labral tears of patients in the second to seventh decades of life without pre-existing OA. © 2016 The Author(s).
Dual redundant arm system operational quality measures and their applications - Dynamic measures
NASA Technical Reports Server (NTRS)
Lee, Sukhan; Kim, Sungbok
1990-01-01
Dual-arm dynamic operation quality measures are presented which quantify the efficiency and capability of generating Cartesian accelerations by two cooperative arms based on the analysis of dual-arm dynamic interactions. Dual-arm dynamic manipulability is defined as the efficiency of generating Cartesian accelerations under the dynamic and kinematic interactions between individual arms and an object under manipulation. The analysis of dual-arm dynamic interactions is based on the so-called Cartesian space agent model of an arm, which represents an individual arm as a force source acting upon a point mass with the effective Cartesian space arm dynamics and an environment or an object under manipulation. The Cartesian space agent model of an arm makes it possible to derive the dynamic and kinematic constraints involved in the transport, assembly and grasping modes of dual-arm cooperation. A task-oriented operational quality measure, (TOQd) is defined by evaluating dual-arm dynamic manipulability in terms of given task requirements. TOQd is used in dual-arm joint configuration optimization. Simulation results are shown. A complete set of forward dynamic equations for a dual-arm system is derived, and dual-arm dynamic operational quality measures for various modes of dual-arm cooperation allowing sliding contacts are established.
Agresta, Cristine; Ward, Christian R; Wright, W Geoffrey; Tucker, Carole A
2018-06-01
Many field sports involve equipment that restricts one or both arms from moving while running. Arm swing during running has been examined from a biomechanical and physiologic perspective but not from an injury perspective. Moreover, only bilateral arm swing suppression has been studied with respect to running. The purpose of this study was to determine the influence of running with one arm restrained on lower extremity mechanics associated with running or sport-related injury. Fifteen healthy participants ran at a self-selected speed with typical arm swing, with one arm restrained and with both arms restrained. Lower extremity kinematics and spatiotemporal measures were analysed for all arm swing conditions. Running with one arm restrained resulted in increased frontal plane knee and hip angles, decreased foot strike angle, and decreased centre of mass vertical displacement compared to typical arm swing or bilateral arm swing restriction. Stride length was decreased and step frequency increased when running with one or both arms restrained. Unilateral arm swing restriction induces changes in lower extremity kinematics that are not similar to running with bilateral arm swing restriction or typical arm swing motion. Running with one arm restrained increases frontal plane mechanics associated with risk of knee injury.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vallée, Jacques P., E-mail: jacques.vallee@nrc-cnrc.gc.ca
2014-07-01
From the Sun's location in the Galactic disk, different arm tracers (CO, H I, hot dust, etc.) have been employed to locate a tangent to each spiral arm. Using all various and different observed spiral arm tracers (as published elsewhere), we embark on a new goal, namely the statistical analysis of these published data (data mining) to statistically compute the mean location of each spiral arm tracer. We show for a typical arm cross-cut, a separation of 400 pc between the mid-arm and the dust lane (at the inner edge of the arm, toward the Galactic center). Are some armsmore » major and others minor? Separating arms into two sets, as suggested by some, we find the same arm widths between the two sets. Our interpretation is that we live in a multiple (four-arm) spiral (logarithmic) pattern (around a pitch angle of 12°) for the stars and gas in the Milky Way, with a sizable interarm separation (around 3 kpc) at the Sun's location and the same arm width for each arm (near 400 pc from mid-arm to dust lane).« less
Capillary electrophoresis-electrochemical detection microchip device and supporting circuits
Jackson, Douglas J [New Albany, IN; Roussel, Jr., Thomas J.; Crain, Mark M [Georgetown, IN; Baldwin, Richard P [Louisville, KY; Keynton, Robert S [Louisville, KY; Naber, John F [Prospect, KY; Walsh, Kevin M [Louisville, KY; Edelen, John G [Versailles, KY
2008-03-18
The present invention is a capillary electrophoresis device, comprising a substrate; a first channel in the substrate, and having a buffer arm and a detection arm; a second channel in the substrate intersecting the first channel, and having a sample arm and a waste arm; a buffer reservoir in fluid communication with the buffer arm; a waste reservoir in fluid communication with the waste arm; a sample reservoir in fluid communication with the sample arm; and a detection reservoir in fluid communication with the detection arm. The detection arm and the buffer arm are of substantially equal length.
Multi-Robot Assembly Strategies and Metrics.
Marvel, Jeremy A; Bostelman, Roger; Falco, Joe
2018-02-01
We present a survey of multi-robot assembly applications and methods and describe trends and general insights into the multi-robot assembly problem for industrial applications. We focus on fixtureless assembly strategies featuring two or more robotic systems. Such robotic systems include industrial robot arms, dexterous robotic hands, and autonomous mobile platforms, such as automated guided vehicles. In this survey, we identify the types of assemblies that are enabled by utilizing multiple robots, the algorithms that synchronize the motions of the robots to complete the assembly operations, and the metrics used to assess the quality and performance of the assemblies.
Non-Line of Sight-Combined Arms (NLOS-CA) Manpower, Personnel and Logistics Impact Analysis (LIA)
1993-11-15
total weight and volume to explosive weight have been used. These measure the size of the round relative to the killing power in the round. On this basis...the weapon system is powered up. (3) Alert Time is that time during which radios are operating, but the system is not powered up. For this analysis...TELEPHONE MANUA: SB-22/PT 1S U99185 UTILITY RECEPTACLE I V31211 TELEPHONE SET TA312 26 V•1788 POWER SUPPLY YE8 HYP-571TSEC 2I N32593 SHOP EQUIP AUTO
DOE Office of Scientific and Technical Information (OSTI.GOV)
KL Gaustad; DD Turner
2007-09-30
This report provides a short description of the Atmospheric Radiation Measurement (ARM) microwave radiometer (MWR) RETrievel (MWRRET) Value-Added Product (VAP) algorithm. This algorithm utilizes complimentary physical and statistical retrieval methods and applies brightness temperature offsets to reduce spurious liquid water path (LWP) bias in clear skies resulting in significantly improved precipitable water vapor (PWV) and LWP retrievals. We present a general overview of the technique, input parameters, output products, and describe data quality checks. A more complete discussion of the theory and results is given in Turner et al. (2007b).
Multi-Robot Assembly Strategies and Metrics
MARVEL, JEREMY A.; BOSTELMAN, ROGER; FALCO, JOE
2018-01-01
We present a survey of multi-robot assembly applications and methods and describe trends and general insights into the multi-robot assembly problem for industrial applications. We focus on fixtureless assembly strategies featuring two or more robotic systems. Such robotic systems include industrial robot arms, dexterous robotic hands, and autonomous mobile platforms, such as automated guided vehicles. In this survey, we identify the types of assemblies that are enabled by utilizing multiple robots, the algorithms that synchronize the motions of the robots to complete the assembly operations, and the metrics used to assess the quality and performance of the assemblies. PMID:29497234
Catalog of Observed Tangents to the Spiral Arms in the Milky Way Galaxy
NASA Astrophysics Data System (ADS)
Vallée, Jacques P.
2014-11-01
From the Sun's location in the Galactic disk, one can use different arm tracers (CO, H I, thermal or ionized or relativistic electrons, masers, cold and hot dust, etc.) to locate a tangent to each spiral arm in the disk of the Milky Way. We present a master catalog of the astronomically observed tangents to the Galaxy's spiral arms, using different arm tracers from the literature. Some arm tracers can have slightly divergent results from several papers, so a mean value is taken—see the Appendix for CO, H II, and masers. The catalog of means currently consists of 63 mean tracer entries, spread over many arms (Carina, Crux-Centaurus, Norma, Perseus origin, near 3 kpc, Scutum, Sagittarius), stemming from 107 original arm tracer entries. Additionally, we updated and revised a previous statistical analysis of the angular offset and linear separation from the mid-arm for each different mean arm tracer. Given enough arm tracers, and summing and averaging over all four spiral arms, one could determine if arm tracers have separate and parallel lanes in the Milky Way. This statistical analysis allows a cross-cut of a Galactic spiral arm to be made, confirming a recent discovery of a linear separation between arm tracers. Here, from the mid-arm's CO to the inner edge's hot dust, the arm halfwidth is about 340 pc doubling would yield a full arm width of 680 pc. We briefly compare these observations with the predictions of many spiral arm theories, notably the density wave theory.
CATALOG OF OBSERVED TANGENTS TO THE SPIRAL ARMS IN THE MILKY WAY GALAXY
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vallée, Jacques P., E-mail: jacques.vallee@nrc-cnrc.gc.ca
2014-11-01
From the Sun's location in the Galactic disk, one can use different arm tracers (CO, H I, thermal or ionized or relativistic electrons, masers, cold and hot dust, etc.) to locate a tangent to each spiral arm in the disk of the Milky Way. We present a master catalog of the astronomically observed tangents to the Galaxy's spiral arms, using different arm tracers from the literature. Some arm tracers can have slightly divergent results from several papers, so a mean value is taken—see the Appendix for CO, H II, and masers. The catalog of means currently consists of 63 meanmore » tracer entries, spread over many arms (Carina, Crux-Centaurus, Norma, Perseus origin, near 3 kpc, Scutum, Sagittarius), stemming from 107 original arm tracer entries. Additionally, we updated and revised a previous statistical analysis of the angular offset and linear separation from the mid-arm for each different mean arm tracer. Given enough arm tracers, and summing and averaging over all four spiral arms, one could determine if arm tracers have separate and parallel lanes in the Milky Way. This statistical analysis allows a cross-cut of a Galactic spiral arm to be made, confirming a recent discovery of a linear separation between arm tracers. Here, from the mid-arm's CO to the inner edge's hot dust, the arm halfwidth is about 340 pc; doubling would yield a full arm width of 680 pc. We briefly compare these observations with the predictions of many spiral arm theories, notably the density wave theory.« less
Tsuge, Mikio; Izumizaki, Masahiko; Kigawa, Kazuyoshi; Atsumi, Takashi; Homma, Ikuo
2012-12-01
We studied the influence of false proprioceptive information generated by arm vibration and false visual information provided by a mirror in which subjects saw a reflection of another arm on perception of arm position, in a forearm position-matching task in right-handed subjects (n = 17). The mirror was placed between left and right arms, and arranged so that the reflected left arm appeared to the subjects to be their unseen right (reference) arm. The felt position of the right arm, indicated with a paddle, was influenced by vision of the mirror image of the left arm. If the left arm appeared flexed in the mirror, subjects felt their right arm to be more flexed than it was. Conversely, if the left arm was extended, they felt their right arm to be more extended than it was. When reference elbow flexors were vibrated at 70-80 Hz, an illusion of extension of the vibrated arm was elicited. The illusion of a more flexed reference arm evoked by seeing a mirror image of the flexed left arm was reduced by vibration. However, the illusion of extension of the right arm evoked by seeing a mirror image of the extended left arm was increased by vibration. That is, when the mirror and vibration illusions were in the same direction, they reinforced each other. However, when they were in opposite directions, they tended to cancel one another. The present study shows the interaction between proprioceptive and visual information in perception of arm position.
Effects of spiral arms on star formation in nuclear rings of barred-spiral galaxies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seo, Woo-Young; Kim, Woong-Tae, E-mail: seowy@astro.snu.ac.kr, E-mail: wkim@astro.snu.ac.kr
2014-09-01
We use hydrodynamic simulations to study the effect of spiral arms on the star formation rate (SFR) in nuclear rings of barred-spiral galaxies. We find that spiral arms can be an efficient means of gas transport from the outskirts to the central parts, provided that the arms are rotating slower than the bar. While the ring star formation in models with no arms or corotating arms is active only during around the bar growth phase, arm-driven gas accretion both significantly enhances and prolongs the ring star formation in models with slow-rotating arms. The arm-enhanced SFR is larger by a factormore » of ∼3-20 than in the no-arm model, with larger values corresponding to stronger and slower arms. Arm-induced mass inflows also make dust lanes stronger. Nuclear rings in slow-arm models are ∼45% larger than in the no-arm counterparts. Star clusters that form in a nuclear ring exhibit an age gradient in the azimuthal direction only when the SFR is small, whereas no notable age gradient is found in the radial direction for models with arm-induced star formation.« less
Camp, Christopher L; Tubbs, Travis G; Fleisig, Glenn S; Dines, Joshua S; Dines, David M; Altchek, David W; Dowling, Brittany
2017-11-01
Likely due to the high level of strain exerted across the elbow during the throwing motion, elbow injuries are on the rise in baseball. To identify at-risk athletes and guide postinjury return-to-throw programs, a better understanding of the variables that influence elbow varus torque is desired. To describe the within-subject relationship between elbow varus torque and arm slot and arm rotation in professional baseball pitchers. Descriptive laboratory study. A total of 81 professional pitchers performed 82,000 throws while wearing a motusBASEBALL sensor and sleeve. These throws represented a combination of throw types, such as warm-up/catch, structured long-toss, bullpen throwing from a mound, and live game activity. Variables recorded for each throw included arm slot (angle of the forearm relative to the ground at ball release), arm speed (maximal rotational velocity of the forearm), arm rotation (maximal external rotation of the throwing arm relative to the ground), and elbow varus torque. Linear mixed-effects models and likelihood ratio tests were used to estimate the relationship between elbow varus torque and arm slot, arm speed, and arm rotation within individual pitchers. All 3 metrics-arm slot (χ 2 = 428, P < .001), arm speed (χ 2 = 57,683, P < .001), and arm rotation (χ 2 = 1392, P < .001)-were found to have a significant relationship with elbow varus torque. Within individual athletes, a 1-N.m increase in elbow varus torque was associated with a 13° decrease in arm slot, a 116 deg/s increase in arm speed, and an 8° increase in arm rotation. Elbow varus torque increased significantly as pitchers increased their arm rotation during the arm cocking phase, increased the rotational velocity of their arm during the arm acceleration phase of throwing, and decreased arm slot at ball release. Thus, shoulder flexibility, arm speed, and elbow varus torque (and likely injury risk) are interrelated and should be considered collectively when treating pitchers. It is well established that elbow varus torque is related to ulnar collateral ligament injuries in overhead throwers. This study describes the relationship of arm slot, arm speed, and arm rotation to elbow varus torque in an attempt to identify modifiable risk factors for injury.
Sundus, Yahya; Dawn, Dawson; Carol, Glaister; Susan, Merrick
2016-01-01
Objective: The aim of this feasibility study is to define the resource effectiveness of cetuximab vs cisplatin given concomitantly with radiotherapy for squamous cell carcinoma within a National Health Service clinical oncology unit. Methods: 20 patients with Stage 3 or 4 head and neck squamous cell cancers were randomized to receive either cetuximab with radiotherapy (ERT) or cisplatin with radiotherapy concurrent with external beam radiotherapy 70 Gy in 35 fractions on a 1 : 1 basis over a 12-month duration. The study compared the resource utilization of ERT vs cisplatin with radiotherapy taking into account drug costs, clinical management and the costs of managing treatment-related toxicity from first fraction of radiotherapy to 6 months after the completion of therapy. Outcome measures were quality of life (recorded at the entry, end of radiotherapy, 6 weeks post treatment and 6 months post treatment), admissions to hospital, delays to radiotherapy, locoregional control and survival. Results: Total drug costs including cost of nutritional supplements for patients treated with cetuximab were £7407.45 compared with £3959.07 for patients treated with cisplatin. Unscheduled admissions for toxicity management were significantly more common in the ERT arm. Healthcare personnel spent significantly more time delivering unscheduled outpatient care for patients receiving cisplatin than for those receiving cetuximab (p = 0.01). No significant difference in the quality of life was suggested at baseline, 6 weeks and 6 months. The mean time to removal of percutaneous gastrostomy (PEG) after completion of radiotherapy was 49.7 weeks in the cisplatin arm and 18.5 weeks in the cetuximab arm (p = 0.04). There was a statistically significant difference in patient-reported use of PEG between the cisplatin and cetuximab arms at 6 months following completion of treatment (p = 0.04). At 21 months, overall survival was 80% in the cisplatin arm vs 50% in the cetuximab (p = 0.332), with disease-free survival being 80% in the cisplatin arm vs 40% in the cetuximab (p = 0.097). Conclusion: Cetuximab is still more expensive in simple drug cost terms than cisplatin when delivered with radiotherapy taking into account costs of drugs for toxicity management and nutritional supplements but other resource implications such as inpatient admission, time spent delivering unscheduled care and cost of additional investigations to manage toxicity for patients treated with cisplatin significantly reduce differential. The study suggested significant differences in patient-reported PEG use at 6 months and in time to PEG removal in favour of the cetuximab arm. Advances in knowledge: There is paucity of randomized data on cost analysis for cisplatin vs cetuximab radiotherapy; this trial informs on the cost analysis between the two approaches. PMID:27734748
Chaillous, Lucy; Franc, Sylvia; Benhamou, Pierre-Yves; Schaepelynck, Pauline; Hanaire, Hélène; Catargi, Bogdan; Farret, Anne; Fontaine, Pierre; Guerci, Bruno; Reznik, Yves; Penfornis, Alfred; Borot, Sophie; Serusclat, Pierre; Kherbachi, Yacine; D'Orsay, Geneviève; Detournay, Bruno; Simon, Pierre; Charpentier, Guillaume
2018-01-01
Background Self-management of diabetes minimizes the risk of macrovascular and microvascular complications, but understanding and/or adherence to self-management recommendations is often suboptimal. DIABEO is a smartphone app (downloaded via the internet) used to calculate bolus insulin doses. A previous study (TELEDIAB 1) showed that the use of DIABEO was associated with a significant improvement in glycemic control in patients with poorly controlled type 1 diabetes mellitus, particularly when combined with teleconsultations with physicians. Objective Here, we present the protocol for a new study (Suivi A Grande Echelle d’une cohorte de diabétiques de type 1 et de type 2 sous schéma insulinique basal bolus par la TELEmédecine; abbreviated TELESAGE), conducted in a larger population of diabetic patients with poorly controlled basal-bolus insulin levels. Methods TELESAGE is a multicenter, double-randomized, open-label, three parallel–arms study, conducted in approximately 100 centers in France. The study will compare a control group (arm 1: usual follow-up) with two DIABEO telemedicine systems: (1) physician-assisted telemedicine (arm 2), and (2) nurse-assisted telemonitoring and teleconsultations by a diabetologist’s task delegation (arm 3). Initial randomization will allocate the study arms in 12 French regions. A second randomization will assign patients in the groups allocated to each studied region. The primary objective of TELESAGE will be to investigate the effect of the DIABEO telemedicine system versus usual follow-up, with respect to improvements in the glycated hemoglobin levels of approximately 696 diabetic patients with poorly controlled basal-bolus insulin levels. Results The TELESAGE study is sponsored by Sanofi (Gentilly, France). A primary completion date is expected in June 2018, and publication of results is expected within 6 months of work completion. Conclusions The TELESAGE study is expected to confirm the previous results of the TELEDIAB 1 study using a larger sample of diabetic patients. It is also expected to evaluate a nurse-assisted telemonitoring system. We will assess the potential of the DIABEO telemedicine service in terms of its utility and explore whether it can become an integral part of diabetes care for patients. Trial Registration ClinicalTrials.gov NCT02287532; https://clinicaltrials.gov/ct2/show/NCT02287532 (Archived by WebCite at http://www.webcitation.org/6ykajhJKd) PMID:29674306
Proprioceptive illusions created by vibration of one arm are altered by vibrating the other arm.
Hakuta, Naoyuki; Izumizaki, Masahiko; Kigawa, Kazuyoshi; Murai, Norimitsu; Atsumi, Takashi; Homma, Ikuo
2014-07-01
There is some evidence that signals coming from both arms are used to determine the perceived position and movement of one arm. We examined whether the sense of position and movement of one (reference) arm is altered by increases in muscle spindle signals in the other (indicator) arm in blindfolded participants (n = 26). To increase muscle spindle discharge, we applied 70-80 Hz muscle vibration to the elbow flexors of the indicator arm. In a first experiment, proprioceptive illusions in the vibrated reference arm in a forearm position-matching task were compared between conditions in which the indicator arm elbow flexors were vibrated or not vibrated. We found that the vibration illusion of arm extension induced by vibration of reference arm elbow flexors was reduced in the presence of vibration of the indicator elbow flexors. In a second experiment, participants were asked to describe their perception of the illusion of forearm extension movements of the reference arm evoked by vibration of reference arm elbow flexors in response to on/off and off/on transitions of vibration of non-reference arm elbow flexors. When vibration of non-reference arm elbow flexors was turned on, they reported a sensation of slowing down of the illusion of the reference arm. When it was turned off, they reported a sensation of speeding up. To conclude, the present study shows that both the sense of limb position and the sense of limb movement of one arm are dependent to some extent on spindle signals coming from the other arm.
Moran, Michael E
2007-01-01
The foundation of surgical robotics is in the development of the robotic arm. This is a thorough review of the literature on the nature and development of this device with emphasis on surgical applications. We have reviewed the published literature and classified robotic arms by their application: show, industrial application, medical application, etc. There is a definite trend in the manufacture of robotic arms toward more dextrous devices, more degrees-of-freedom, and capabilities beyond the human arm. da Vinci designed the first sophisticated robotic arm in 1495 with four degrees-of-freedom and an analog on-board controller supplying power and programmability. von Kemplen's chess-playing automaton left arm was quite sophisticated. Unimate introduced the first industrial robotic arm in 1961, it has subsequently evolved into the PUMA arm. In 1963 the Rancho arm was designed; Minsky's Tentacle arm appeared in 1968, Scheinman's Stanford arm in 1969, and MIT's Silver arm in 1974. Aird became the first cyborg human with a robotic arm in 1993. In 2000 Miguel Nicolalis redefined possible man-machine capacity in his work on cerebral implantation in owl-monkeys directly interfacing with robotic arms both locally and at a distance. The robotic arm is the end-effector of robotic systems and currently is the hallmark feature of the da Vinci Surgical System making its entrance into surgical application. But, despite the potential advantages of this computer-controlled master-slave system, robotic arms have definite limitations. Ongoing work in robotics has many potential solutions to the drawbacks of current robotic surgical systems.
Elevated Radiation Exposure Associated With Above Surface Flat Detector Mini C-Arm Use.
Martin, Dennis P; Chapman, Talia; Williamson, Christopher; Tinsley, Brian; Ilyas, Asif M; Wang, Mark L
2017-11-01
This study aims to test the hypothesis that: (1) radiation exposure is increased with the intended use of Flat Surface Image Intensifier (FSII) units above the operative surface compared with the traditional below-table configuration; (2) this differential increases in a dose-dependent manner; and (3) radiation exposure varies with body part and proximity to the radiation source. A surgeon mannequin was seated at a radiolucent hand table, positioned for volar distal radius plating. Thermoluminescent dosimeters measured exposure to the eyes, thyroid, chest, hand, and groin, for 1- and 15-minute trials from a mini C-arm FSII unit positioned above and below the operating surface. Background radiation was measured by control dosimeters placed within the operating theater. At 1-minute of exposure, hand and eye dosages were significantly greater with the flat detector positioned above the table. At 15-minutes of exposure, hand radiation dosage exceeded that of all other anatomic sites with the FSII in both positions. Hand exposure was increased in a dose-dependent manner with the flat detector in either position, whereas groin exposure saw a dose-dependent only with the flat detector beneath the operating table. These findings suggest that the surgeon's hands and eyes may incur greater radiation exposure compared with other body parts, during routine mini C-arm FSII utilization in its intended position above the operating table. The clinical impact of these findings remains unclear, and future long-term radiation safety investigation is warranted. Surgeons should take precautions to protect critical body parts, particularly when using FSII technology above the operating with prolonged exposure time.
Measuring Micro-Friction Torque in MEMS Gas Bearings
Fang, Xudong; Liu, Huan
2016-01-01
An in situ measurement of micro-friction torque in MEMS gas bearings, which has been a challenging research topic for years, is realized by a system designed in this paper. In the system, a high accuracy micro-force sensor and an electronically-driven table are designed, fabricated and utilized. With appropriate installation of the sensor and bearings on the table, the engine rotor can be driven to rotate with the sensor using a silicon lever beam. One end of the beam is fixed to the shaft of the gas bearing, while the other end is free and in contact with the sensor probe tip. When the sensor begins to rotate with the table, the beam is pushed by the sensor probe to rotate in the same direction. For the beam, the friction torque from the gas bearing is balanced by the torque induced by pushing force from the sensor probe. Thus, the friction torque can be calculated as a product of the pushing force measured by the sensor and the lever arm, which is defined as the distance from the sensor probe tip to the centerline of the bearing. Experimental results demonstrate the feasibility of this system, with a sensitivity of 1.285 mV/μN·m in a range of 0 to 11.76 μN·m when the lever arm is 20 mm long. The measuring range can be modified by varying the length of the lever arm. Thus, this system has wide potential applications in measuring the micro-friction torque of gas bearings in rotating MEMS machines. PMID:27213377
A new 2DS·2RL Robertsonian translocation transfers stem rust resistance gene Sr59 into wheat.
Rahmatov, Mahbubjon; Rouse, Matthew N; Nirmala, Jayaveeramuthu; Danilova, Tatiana; Friebe, Bernd; Steffenson, Brian J; Johansson, Eva
2016-07-01
A new stem rust resistance gene Sr59 from Secale cereale was introgressed into wheat as a 2DS·2RL Robertsonian translocation. Emerging new races of the wheat stem rust pathogen (Puccinia graminis f. sp. tritici), from Africa threaten global wheat (Triticum aestivum L.) production. To broaden the resistance spectrum of wheat to these widely virulent African races, additional resistance genes must be identified from all possible gene pools. From the screening of a collection of wheat-rye (Secale cereale L.) chromosome substitution lines developed at the Swedish University of Agricultural Sciences, we described the line 'SLU238' 2R (2D) as possessing resistance to many races of P. graminis f. sp. tritici, including the widely virulent race TTKSK (isolate synonym Ug99) from Africa. The breakage-fusion mechanism of univalent chromosomes was used to produce a new Robertsonian translocation: T2DS·2RL. Molecular marker analysis and stem rust seedling assays at multiple generations confirmed that the stem rust resistance from 'SLU238' is present on the rye chromosome arm 2RL. Line TA5094 (#101) was derived from 'SLU238' and was found to be homozygous for the T2DS·2RL translocation. The stem rust resistance gene on chromosome 2RL arm was designated as Sr59. Although introgressions of rye chromosome arms into wheat have most often been facilitated by irradiation, this study highlights the utility of the breakage-fusion mechanism for rye chromatin introgression. Sr59 provides an additional asset for wheat improvement to mitigate yield losses caused by stem rust.
Hwang, Seonhong; Tsai, Chung-Ying; Koontz, Alicia M
2017-05-24
The purpose of this study was to test the concurrent validity and test-retest reliability of the Kinect skeleton tracking algorithm for measurement of trunk, shoulder, and elbow joint angle measurement during a wheelchair transfer task. Eight wheelchair users were recruited for this study. Joint positions were recorded simultaneously by the Kinect and Vicon motion capture systems while subjects transferred from their wheelchairs to a level bench. Shoulder, elbow, and trunk angles recorded with the Kinect system followed a similar trajectory as the angles recorded with the Vicon system with correlation coefficients that are larger than 0.71 on both sides (leading arm and trailing arm). The root mean square errors (RMSEs) ranged from 5.18 to 22.46 for the shoulder, elbow, and trunk angles. The 95% limits of agreement (LOA) for the discrepancy between the two systems exceeded the clinical significant level of 5°. For the trunk, shoulder, and elbow angles, the Kinect had very good relative reliability for the measurement of sagittal, frontal and horizontal trunk angles, as indicated by the high intraclass correlation coefficient (ICC) values (>0.90). Small standard error of the measure (SEM) values, indicating good absolute reliability, were observed for all joints except for the leading arm's shoulder joint. Relatively large minimal detectable changes (MDCs) were observed in all joint angles. The Kinect motion tracking has promising performance levels for some upper limb joints. However, more accurate measurement of the joint angles may be required. Therefore, understanding the limitations in precision and accuracy of Kinect is imperative before utilization of Kinect.
Design of the Economic Evaluation for the Interventional Management of Stroke (III) Trial
Mauldin, Patrick D.; Simpson, Kit N.; Palesch, Yuko Y.; Spilker, Judy S.; Hill, Michael D.; Khatri, Pooja; Broderick, Joseph P.
2011-01-01
SUMMARY Rationale Stroke is a common and costly condition where an effective early reatment may be expected to affect patients’ future quality of life, the cost of acute medical treatment, and the cost of rehabilitation and any supportive care needed for their remaining lifetime. To assist in informing discussions on early adoption of potential treatments, economic analyses should accompany investigations that seek to improve outcomes for stroke patients. Aims The primary aim is to assess whether IV/IA rt-PA therapy is cost-effective at 3 months compared to IV rt-PA, and provides cost-savings or is cost-neutral by 12 months. Design Cost-effectiveness of the two treatment arms will be measured at months 3, 6, 9, and 12. Cost-effectiveness will be calculated using 1) standard cost-effectiveness methodology (Incremental Cost-Effectiveness Ratios), and 2) an econometric model to assess multiple outcome measures while controlling for multiple subject and treatment-related factors that are known to affect both outcomes and costs. Study Outcomes Total cost for the initial hospitalization of treating stroke subjects randomized to either IV/IA or IV rt-PA treatment arms will be measured, as will differences in types of resource utilization over 12 months between the two arms of the trial. Quality-of-life data (EuroQol EQ-5D) will be collected over a 12-month period and quality adjusted life years (QALYs) will be used as a morbidity-adjusted measure of effectiveness. Subgroup analyses will include dichotomized NIH Stroke Scale (<20, ≥20), country, time between onset and randomization, and IA devices. PMID:18706008
Flood, Chris; Mugford, Miranda; Stewart, Sandra; Harvey, Ian; Poland, Fiona; Lloyd-Smith, Walter
2005-01-01
To compare costs and outcome of occupational therapy-led assessment with social worker-led assessment of older people, in terms of their independence and quality of life. Cost-effectiveness analysis alongside a randomised controlled trial. The analysis took viewpoints of health services and patients. The primary outcome measure for cost-effectiveness was dependency using the Community Dependency Index (CDI). Secondary outcomes included utility scores based on the EuroQoL (EQ-5D). Resource use was measured for each patient, from clinical records and from patient carer interviews at 8 months. Unit costs of health and social care resources were derived from local sources and national datasets. Cost-effectiveness was analysed using cost-effectiveness acceptability curves. There were no differences between the two arms of the trial in terms of cost-effectiveness. There is an apparent increase in mean cost per case for the occupational therapy arm but this is not statistically significant (mean difference in cost per case 542 pounds, 95% CI 434-1,519 pounds). Mean total costs of care per participant were 4,379 pounds and 3,837 pounds for the occupational therapy and social work arms, respectively. At best the intervention would improve outcomes at a cost of 14,000 pounds per quality-adjusted life year (QALY). The probability of such an outcome was <50%. From a policy perspective, the lack of difference in clinical and cost-effectiveness means that either a social work or an occupational therapy service is successful in making care assessments that enable an older person to remain in their own home.
Wang, Zi-nian; Cai, Han-fang; Li, Ming-xun; Cao, Xiu-kai; Lan, Xian-yong; Lei, Chu-zhao; Chen, Hong
2016-01-10
Patatin-like phospholipase domain-containing protein 3 (PNPLA3), a member of the patatin like phospholipase domain-containing (PNPLA) family, plays an important role in energy balance, fat metabolism regulation, glucose metabolism and fatty liver disease. Tetra-primer amplification refractory mutation system PCR (T-ARMS-PCR) is a new method offering fast detection and extreme simplicity at a negligible cost for SNP genotyping. In this paper, we investigated the genetic variations at different ages of 660 Chinese indigenous cattle belonging to three breeds (QC, NY, JX) and applied T-ARMS-PCR and PCR-RFLP methods to genotype four SNPs, SNP1: g.A2980G, SNP2: g.A2996T, SNP3: g.A36718G, SNP4: g.G36850A. The statistical analyses indicated that these 4 SNPs affected growth traits markedly (P<0.05) in QC population, whereas combined haplotypes were not (P>0.05). The qPCR (quantitative PCR) indicated that bovine PNPLA3 gene was exclusively expressed in fat tissues. Besides, the analysis between SNP and mRNA expression revealed that, in SNP1, the expression of AG was much higher than AA and GG (P<0.05), which was in accordance with the results of growth traits association analysis, while the results of SNP4 was not. These results supported high potential that SNPs of bovine PNPLA3 gene might be utilized as genetic markers in marker-assisted selection (MAS) for Chinese cattle breeding programs. Copyright © 2015 Elsevier B.V. All rights reserved.
The Potential Uses of Commercial Satellite Imagery in the Middle East
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vannoni, M.G.
1999-06-08
It became clear during the workshop that the applicability of commercial satellite imagery to the verification of future regional arms control agreements is limited at this time. Non-traditional security topics such as environmental protection, natural resource management, and the development of infrastructure offer the more promising applications for commercial satellite imagery in the short-term. Many problems and opportunities in these topics are regional, or at least multilateral, in nature. A further advantage is that, unlike arms control and nonproliferation applications, cooperative use of imagery in these topics can be done independently of the formal Middle East Peace Process. The valuemore » of commercial satellite imagery to regional arms control and nonproliferation, however, will increase during the next three years as new, more capable satellite systems are launched. Aerial imagery, such as that used in the Open Skies Treaty, can also make significant contributions to both traditional and non-traditional security applications but has the disadvantage of requiring access to national airspace and potentially higher cost. There was general consensus that commercial satellite imagery is under-utilized in the Middle East and resources for remote sensing, both human and institutional, are limited. This relative scarcity, however, provides a natural motivation for collaboration in non-traditional security topics. Collaborations between scientists, businesses, universities, and non-governmental organizations can work at the grass-roots level and yield contributions to confidence building as well as scientific and economic results. Joint analysis projects would benefit the region as well as establish precedents for cooperation.« less
Macciò, Antonio; Madeddu, Clelia; Serpe, Roberto; Massa, Elena; Dessì, Mariele; Panzone, Filomena; Contu, Paolo
2010-01-01
Purpose. A phase III, randomized study was carried out to establish the most effective and safest treatment to improve the primary endpoints of cancer cachexia—lean body mass (LBM), resting energy expenditure (REE), and fatigue—and relevant secondary endpoints: appetite, quality of life, grip strength, Glasgow Prognostic Score (GPS) and proinflammatory cytokines. Patients and Methods. Three hundred thirty-two assessable patients with cancer-related anorexia/cachexia syndrome were randomly assigned to one of five treatment arms: arm 1, medroxyprogesterone (500 mg/day) or megestrol acetate (320 mg/day); arm 2, oral supplementation with eicosapentaenoic acid; arm 3, L-carnitine (4 g/day); arm 4, thalidomide (200 mg/day); and arm 5, a combination of the above. Treatment duration was 4 months. Results. Analysis of variance showed a significant difference between treatment arms. A post hoc analysis showed the superiority of arm 5 over the others for all primary endpoints. An analysis of changes from baseline showed that LBM (by dual-energy X-ray absorptiometry and by L3 computed tomography) significantly increased in arm 5. REE decreased significantly and fatigue improved significantly in arm 5. Appetite increased significantly in arm 5; interleukin (IL)-6 decreased significantly in arm 5 and arm 4; GPS and Eastern Cooperative Oncology Group performance status (ECOG PS) score decreased significantly in arm 5, arm 4, and arm 3. Toxicity was quite negligible, and was comparable between arms. Conclusion. The most effective treatment in terms of all three primary efficacy endpoints and the secondary endpoints appetite, IL-6, GPS, and ECOG PS score was the combination regimen that included all selected agents. PMID:20156909
The position of the arm during blood pressure measurement in sitting position.
Adiyaman, Ahmet; Verhoeff, Rutger; Lenders, Jacques W M; Deinum, Jaap; Thien, Theo
2006-12-01
Determining the influence of the position of the arm on blood pressure measurement in the sitting position. Blood pressure of 128 individuals (the majority being treated hypertensive patients) visiting the outpatient clinic was measured simultaneously on both arms with arms in two different positions. First, both arms were placed at the chair support level and blood pressure was measured three times on both arms after 10 min of rest. Subsequently, while still remaining in the same sitting position, five blood pressure measurements were made simultaneously at both arms with one arm placed on the desk and one arm placed and supported at heart level (mid-sternal). The arm placed at heart level served as the reference arm. The choice of which arm was placed at desk level and which arm was placed at heart level was randomized. Both at desk level and at chair support level, mean (+/-SD) systolic and diastolic blood pressures were higher than blood pressure at heart level by 6.1/5.7+/-4.6/3.1 and 9.3/9.4+/-5.4/3.4 mmHg, respectively. The effect of the height differences between the arm positions on the blood pressure readings was smaller than predicted (0.49 mmHg/cm systolic and 0.47 mmHg/cm diastolic). No significant correlation was found between blood pressure difference in the different arm positions (desk and heart level) and age, sex, weight or baseline blood pressure. Different arm positions below heart level have significant effects on blood pressure readings. The leading guidelines about arm position during blood pressure measurement are not in accordance with the arm position used in the Framingham study, the most frequently used study for risk estimations.
Han, Chao; Yang, Ben; Zuo, Wen-Shu; Zheng, Gang; Yang, Li; Zheng, Mei-Zhu
2016-01-01
Objective The axillary reverse mapping (ARM) technique has recently been developed to prevent lymphedema by preserving the arm lymphatic drainage during sentinel lymph node biopsy (SLNB) or axillary lymph node dissection (ALND) procedures. The objective of this systematic review and meta-analysis was to evaluate the feasibility and oncological safety of ARM. Methods We searched Medline, Embase, Web of science, Scopus, and the Cochrane Library for relevant prospective studies. The identification rate of ARM nodes, the crossover rate of SLN-ARM nodes, the proportion of metastatic ARM nodes, and the incidence of complications were pooled into meta-analyses by the random-effects model. Results A total of 24 prospective studies were included into meta-analyses, of which 11 studies reported ARM during SLNB, and 18 studies reported ARM during SLNB. The overall identification rate of ARM nodes was 38.2% (95% CI 32.9%-43.8%) during SLNB and 82.8% (78.0%-86.6%) during ALND, respectively. The crossover rate of SLN-ARM nodes was 19.6% (95% CI 14.4%-26.1%). The metastatic rate of ARM nodes was 16.9% (95% CI 14.2%-20.1%). The pooled incidence of lymphedema was 4.1% (95% CI 2.9–5.9%) for patients undergoing ARM procedure. Conclusions The ARM procedure was feasible during ALND. Nevertheless, it was restricted by low identification rate of ARM nodes during SLNB. ARM was beneficial for preventing lymphedema. However, this technique should be performed with caution given the possibility of crossover SLN-ARM nodes and metastatic ARM nodes. ARM appeared to be unsuitable for patients with clinically positive breast cancer due to oncological safety concern. PMID:26919589
Cortical Spiking Network Interfaced with Virtual Musculoskeletal Arm and Robotic Arm.
Dura-Bernal, Salvador; Zhou, Xianlian; Neymotin, Samuel A; Przekwas, Andrzej; Francis, Joseph T; Lytton, William W
2015-01-01
Embedding computational models in the physical world is a critical step towards constraining their behavior and building practical applications. Here we aim to drive a realistic musculoskeletal arm model using a biomimetic cortical spiking model, and make a robot arm reproduce the same trajectories in real time. Our cortical model consisted of a 3-layered cortex, composed of several hundred spiking model-neurons, which display physiologically realistic dynamics. We interconnected the cortical model to a two-joint musculoskeletal model of a human arm, with realistic anatomical and biomechanical properties. The virtual arm received muscle excitations from the neuronal model, and fed back proprioceptive information, forming a closed-loop system. The cortical model was trained using spike timing-dependent reinforcement learning to drive the virtual arm in a 2D reaching task. Limb position was used to simultaneously control a robot arm using an improved network interface. Virtual arm muscle activations responded to motoneuron firing rates, with virtual arm muscles lengths encoded via population coding in the proprioceptive population. After training, the virtual arm performed reaching movements which were smoother and more realistic than those obtained using a simplistic arm model. This system provided access to both spiking network properties and to arm biophysical properties, including muscle forces. The use of a musculoskeletal virtual arm and the improved control system allowed the robot arm to perform movements which were smoother than those reported in our previous paper using a simplistic arm. This work provides a novel approach consisting of bidirectionally connecting a cortical model to a realistic virtual arm, and using the system output to drive a robotic arm in real time. Our techniques are applicable to the future development of brain neuroprosthetic control systems, and may enable enhanced brain-machine interfaces with the possibility for finer control of limb prosthetics.
Go, Vivian F; Frangakis, Constantine; Le Minh, Nguyen; Ha, Tran Viet; Latkin, Carl A; Sripaipan, Teerada; Zelaya, Carla E; Davis, Wendy W; Celentano, David D; Quan, Vu Minh
2017-02-01
In Vietnam, where 58% of prevalent HIV cases are attributed to people who inject drugs, we evaluated whether a multi-level intervention could improve care outcomes and increase survival. We enrolled 455 HIV-infected males who inject drugs from 32 communes in Thai Nguyen Province. Communes were randomized to a community stigma reduction intervention or standard of care and then within each commune, to an individual enhanced counseling intervention or standard of care, resulting into 4 arms: Arm 1 (standard of care); Arm 2 (community intervention alone); Arm 3 (individual intervention alone); and Arm 4 (community + individual interventions). Follow-up was conducted at 6, 12, 18, and 24 months to assess survival. Overall mortality was 23% (n = 103/455) more than 2 years. There were no losses to follow-up for the mortality endpoint. Survival at 24 months was different across arms: Arm 4 (87%) vs Arm 1 (82%) vs Arm 2 (68%) vs Arm 3 (73%); log-rank test for comparison among arms: P = 0.001. Among those with CD4 cell count <200 cells/mm and not on antiretroviral therapy at baseline (n = 162), survival at 24 months was higher in Arm 4 (84%) compared with other arms (Arm 1: 61%; Arm 2: 50%; Arm 3: 53%; P-value = 0.002). Overall, Arm 4 (community + individual interventions) had increased uptake of antiretroviral therapy compared with Arms 1, 2, and 3. This multi-level behavioral intervention seemed to increase survival of HIV-infected participants more than a 2-year period. Relative to the standard of care, the greatest intervention effect was among those with lower CD4 cell counts.
Ustinova, Ksenia I; Feldman, Anatol G; Levin, Mindy F
2013-06-01
The paretic arm of subjects with stroke has a decreased ability to quickly adapt to and recover from perturbations during rhythmical arm swinging. We investigated whether bilateral coupling in the synchronous motion of two arms may facilitate the restoration of rhythmical movement of the paretic arm in subjects with chronic hemiparesis due to stroke. While standing, stroke and age-matched healthy (control) subjects swung one or both arms synchronously at ~0.8 Hz from the shoulder joints. In randomly selected cycles, one arm was transiently arrested by an electromagnetic device when moving forward or backward. In the control group, bilateral swinging resumed faster than unilateral swinging regardless of which arm was perturbed. In the stroke group, this effect was observed only when the perturbation was applied to the paretic arm, suggesting that the motion of the non-paretic arm accelerated the recovery from perturbation of the paretic arm. In addition, bilateral swinging resumed after reduced anterior-posterior excursions of both arms in stroke subjects. Results confirm previous findings that bilateral swinging is normally guided by central changes in the referent configuration of the two arms that function as a single unit. As a consequence, both arms cooperate in recovery from perturbation of motion applied to one arm. Results also suggest that stroke-related brain damage alters the symmetry of bilateral interaction, resulting in deficits of inter-manual cooperative action. The involvement of the non-paretic arm could be beneficial for the recovery of swinging of both arms and may also facilitate movements of the paretic arm in certain tasks.
McElfish, Pearl Anna; Long, Christopher R; Kaholokula, Joseph Keawe'aimoku; Aitaoto, Nia; Bursac, Zoran; Capelle, Lucy; Laelan, Melisa; Bing, Williamina Ioanna; Riklon, Sheldon; Rowland, Brett; Ayers, Britni L; Wilmoth, Ralph O; Langston, Krista N; Schootman, Mario; Selig, James P; Yeary, Karen Hye-Cheon Kim
2018-05-01
Pacific Islander populations, including Marshallese, face a disproportionately high burden of health disparities relative to the general population. A community-based participatory research (CBPR) approach was utilized to engage Marshallese participants in a comparative effectiveness trial testing 2 Diabetes Prevention Program (DPP) interventions designed to reduce participant's weight, lower HbA1c, encourage healthy eating, and increase physical activity. To compare the effectiveness of the faith-based (WORD) DPP to the culturally adapted (Pacific Culturally Adapted Diabetes Prevention Program [PILI]) DPP, a clustered randomized controlled trial (RCT) with 384 Marshallese participants will be implemented in 32 churches located in Arkansas, Kansas, Missouri, and Oklahoma. Churches will be randomly assigned to WORD DPP arm or to PILI DPP arm. WORD DPP focuses on connecting faith and health to attain a healthy weight, eat healthy, and be more physically active. In contrast, PILI DPP is a family and community focused DPP curriculum specifically adapted for implementation in Pacific Islander communities. PILI focuses on engaging social support networks to maintain a healthy weight, eat healthy, and be more physically active. All participants are assessed at baseline, immediate post intervention, and 12 months post intervention. Both interventions aim to cause weight loss through improving physical activity and healthy eating, with the goal of preventing the development of T2D. The clustered RCT will determine which intervention is most effective with the Marshallese population. The utilization of a CBPR approach that involves local stakeholders and engages faith-based institutions in Marshallese communities will increase the potential for success and sustainability. This study is registered at clinicaltrials.gov (NCT03270436).
McElfish, Pearl Anna; Long, Christopher R.; Kaholokula, Joseph Keawe‘aimoku; Aitaoto, Nia; Bursac, Zoran; Capelle, Lucy; Laelan, Melisa; Bing, Williamina Ioanna; Riklon, Sheldon; Rowland, Brett; Ayers, Britni L.; Wilmoth, Ralph O.; Langston, Krista N.; Schootman, Mario; Selig, James P.; Yeary, Karen Hye-cheon Kim
2018-01-01
Abstract Background: Pacific Islander populations, including Marshallese, face a disproportionately high burden of health disparities relative to the general population. Objectives: A community-based participatory research (CBPR) approach was utilized to engage Marshallese participants in a comparative effectiveness trial testing 2 Diabetes Prevention Program (DPP) interventions designed to reduce participant's weight, lower HbA1c, encourage healthy eating, and increase physical activity. Design: To compare the effectiveness of the faith-based (WORD) DPP to the culturally adapted (Pacific Culturally Adapted Diabetes Prevention Program [PILI]) DPP, a clustered randomized controlled trial (RCT) with 384 Marshallese participants will be implemented in 32 churches located in Arkansas, Kansas, Missouri, and Oklahoma. Churches will be randomly assigned to WORD DPP arm or to PILI DPP arm. Methods: WORD DPP focuses on connecting faith and health to attain a healthy weight, eat healthy, and be more physically active. In contrast, PILI DPP is a family and community focused DPP curriculum specifically adapted for implementation in Pacific Islander communities. PILI focuses on engaging social support networks to maintain a healthy weight, eat healthy, and be more physically active. All participants are assessed at baseline, immediate post intervention, and 12 months post intervention. Summary: Both interventions aim to cause weight loss through improving physical activity and healthy eating, with the goal of preventing the development of T2D. The clustered RCT will determine which intervention is most effective with the Marshallese population. The utilization of a CBPR approach that involves local stakeholders and engages faith-based institutions in Marshallese communities will increase the potential for success and sustainability. This study is registered at clinicaltrials.gov (NCT03270436). PMID:29742712
Chen, Neal C; Shauver, Melissa J; Chung, Kevin C
2011-11-01
We undertook a cost-utility analysis to compare traditional fasciectomy for Dupuytren with 2 new treatments, needle aponeurotomy and collagenase injection. We constructed an expected-value decision analysis model with an arm representing each treatment. A survey was administered to a cohort of 50 consecutive subjects to determine utilities of different interventions. We conducted multiple sensitivity analyses to assess the impact of varying the rate of disease recurrence in each arm of the analysis as well as the cost of the collagenase injection. The threshold for a cost-effective treatment is based on the traditional willingness-to-pay of $50,000 per quality-adjusted life years (QALY) gained. The cost of open partial fasciectomy was $820,114 per QALY gained over no treatment. The cost of needle aponeurotomy was $96,474 per QALY gained versus no treatment. When we performed a sensitivity analysis and set the success rate at 100%, the cost of needle aponeurotomy was $49,631. When needle aponeurotomy was performed without surgical center or anesthesia costs and with reduced hand therapy, the cost was $36,570. When a complete collagenase injection series was priced at $250, the cost was $31,856 per QALY gained. When the injection series was priced at $945, the cost was $49,995 per QALY gained. At the market price of $5,400 per injection, the cost was $166,268 per QALY gained. In the current model, open partial fasciectomy is not cost-effective. Needle aponeurotomy is cost-effective if the success rate is high. Collagenase injection is cost-effective when priced under $945. Economic and Decision Analysis II. Copyright © 2011 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Connell, Louise A; McMahon, Naoimh E; Tyson, Sarah F; Watkins, Caroline L; Eng, Janice J
2016-12-01
Current approaches to upper limb rehabilitation are not sufficient to drive neural reorganization and maximize recovery after stroke. To address this evidence-practice gap, a knowledge translation intervention using the Behaviour Change Wheel was developed. The intervention involves collaboratively working with stroke therapy teams to change their practice and increase therapy intensity by therapists prescribing supplementary self-directed arm exercise. The purposes of this case series are: (1) to provide an illustrative example of how a research-informed process changed clinical practice and (2) to report on staff members' and patients' perceptions of the utility of the developed intervention. A participatory action research approach was used in 3 stroke rehabilitation units in the United Kingdom. The intervention aimed to change 4 therapist-level behaviors: (1) screening patients for suitability for supplementary self-directed arm exercise, (2) provision of exercises, (3) involving family and caregivers in assisting with exercises, and (4) monitoring and progressing exercises. Data on changes in practice were collected by therapy teams using a bespoke audit tool. Utility of the intervention was explored in qualitative interviews with patients and staff. Components of the intervention were successfully embedded in 2 of the 3 stroke units. At these sites, almost all admitted patients were screened for suitability for supplementary self-directed exercise. Exercises were provided to 77%, 70%, and 88% of suitable patients across the 3 sites. Involving family and caregivers and monitoring and progressing exercises were not performed consistently. This case series is an example of how a rigorous research-informed knowledge translation process resulted in practice change. Research is needed to demonstrate that these changes can translate into increased intensity of upper limb exercise and affect patient outcomes. © 2016 American Physical Therapy Association.
Radhakrishnan, Renjith Kalathoorakathu; Mittal, Bhagwant Rai; Gorla, Arun Kumar Reddy; Basher, Rajender Kumar; Sood, Ashwani; Bal, Amanjit; Kalra, Naveen; Khandelwal, Niranjan; Singh, Navneet; Behera, Digambar
2017-12-01
The aim of this study was to assess the feasibility and appraise the diagnostic utility of real time 18 F-FDG PET/CT-guided biopsy under automated robopsy arm (ARA) guidance for the evaluation of thoracic lesions with prior inconclusive biopsy results. PET/CT-guided biopsy of thoracic lesions was performed in patients who had at least one previous inconclusive biopsy. A total of 25 patients (male:female-18 males, 7 females; age: range, 13-75; mean, 53.7) were included in this study. All these patients underwent percutaneous needle biopsies under real-time PET/CT guidance using ARA (ROBIO-EX, Perfint healthcare Pvt Ltd, Chennai, India) needle navigation technique. Histopathology and clinical follow-up results were reviewed for assessing the accuracy of procedures. Adequate representative tissue sample could be retrieved in all the patients. No major procedure-related complications were encountered in any patient. Of the 25 procedures, 21 lesions were positive for malignancy and benign findings were observed in the other 4 lesions on histopathology. None of the patients required further biopsy in arriving at a final diagnosis. Overall diagnostic yield of the procedure was 100%. Real time 18 F-FDG PET/CT guidance for percutaneous biopsies of lung and mediastinal lesions is a feasible technique with potential utility in patients with previous inconclusive biopsy results. Advances in knowledge: 18 F-FDG PET/CT guidance reduces the sampling errors by specifically targeting areas of viability and avoiding necrosis/atelectasis. A navigational tool like ARA is thought to help in accurately targeting these areas.
Becker, Debbie L; Chit, Ayman; DiazGranados, Carlos A; Maschio, Michael; Yau, Eddy; Drummond, Michael
2016-12-01
Seasonal influenza infects approximately 10-20% of Canadians each year, causing an estimated 12,200 hospitalizations and 3,500 deaths annually, mostly occurring in adults ≥65 years old (seniors). A 32,000-participant, randomized controlled clinical trial (FIM12; Clinicaltrials.gov NCT01427309) showed that high-dose inactivated influenza vaccine (IIV-HD) is superior to standard-dose vaccine (SD) in preventing laboratory-confirmed influenza illness in seniors. In this study, we performed a cost-utility analysis (CUA) of IIV-HD versus SD in FIM12 participants from a Canadian perspective. Healthcare resource utilization data collected in FIM12 included: medications, non-routine/urgent care and emergency room visits, and hospitalizations. Unit costs were applied using standard Canadian cost sources to estimate the mean direct medical and societal costs associated with each vaccine (2014 CAD). Clinical illness data from the trial were mapped to quality-of-life data from the literature to estimate differences in effectiveness between vaccines. Time horizon was one influenza season, however, quality-adjusted life-years (QALYs) lost due to death during the study were captured over a lifetime. A probabilistic sensitivity analysis (PSA) was also performed. Average per-participant medical costs were $47 lower and societal costs $60 lower in the IIV-HD arm. Hospitalizations contributed 91% of the total cost and were less frequent in the IIV-HD arm. IIV-HD provided a gain in QALYs and, due to cost savings, dominated SD in the CUA. The PSA indicated that IIV-HD is 89% likely to be cost saving. In Canada, IIV-HD is expected to be a less costly and more effective alternative to SD, driven by a reduction in hospitalizations.
Deficits in novelty exploration after controlled cortical impact.
Wagner, Amy K; Postal, Brett A; Darrah, Shaun D; Chen, Xiangbai; Khan, Amina S
2007-08-01
Experimental models of traumatic brain injury (TBI) have been utilized to characterize the behavioral derangements associated with brain trauma. Several studies exist characterizing motor function in the controlled cortical impact (CCI) injury model of TBI, but less research has focused on how CCI affects exploratory behavior. The goal of this study was to characterize deficits in three novelty exploration tasks after the CCI. Under anesthesia, 37 adult male Sprague Dawley rats received CCI (2.7 mm and 2.9 mm; 4 m/sec) over the right parietal cortex or sham surgery. For days 1-6 post-surgery, the beam balance and beam walking tasks were used to assess motor deficits. The Open Field, Y-Maze, and Free Choice Novelty (FCN) tasks were used to measure exploratory deficits from days 7-14 post-surgery. Injured rats displayed a significant, but transient, deficit on each motor task (p < 0.0001). Open Field results showed that injured rats had lower activity levels than shams (p < 0.0001), displayed less habituation to the task, and had more anxiety related behaviors (thigmotaxis) across days (p < 0.0001). Y-maze results suggest that injured rats spent less time in the novel arm versus the familiar arms when compared to shams (p < 0.0001). For FCN, injured rats were less active (p < 0.05) and spent less time and had fewer interactions with objects in the novel environment compared to shams (p < 0.05). These results suggest that several ethological factors contribute to exploratory deficits after CCI and can be effectively characterized with the behavioral tasks described. Future work will utilize these tasks to evaluate the neural substrates underlying exploratory deficits after TBI.
Hall, Charlotte L; James, Marilyn; Brown, Sue; Martin, Jennifer L; Brown, Nikki; Selby, Kim; Clarke, Julie; Vijayan, Hena; Guo, Boliang; Sayal, Kapil; Hollis, Chris; Groom, Madeleine J
2018-02-15
Attention-deficit hyperactivity disorder (ADHD) is characterised by symptoms of inattention, hyperactivity and impulsivity. To improve outcomes, the National Institute for Health and Care Excellence ADHD guidelines recommend regular monitoring of symptoms when children commence medication. However, research suggests that routine monitoring rarely happens, and clinicians often rely on subjective information such as reports from parents and teachers to ascertain improvement. These sources can be unreliable and difficult to obtain. The addition of an objective test of attention and activity (QbTest) may improve the objectivity, reliability and speed of clinical decision-making and so reduce the time to identify the optimal medication dose. This study aims to assess the feasibility and acceptability of a QbTest medication management protocol delivered in routine healthcare services for children with ADHD. This multisite feasibility randomised controlled trial (RCT) will recruit 60 young people (aged 6-17 years old), diagnosed with ADHD, and starting stimulant medication who are seen by Child and Adolescent Mental Health Services or Community Paediatric services. Participants will be randomised into one of two arms. In the experimental arm (QbTest protocol), the participant will complete a QbTest at baseline (prior to medication initiation), and two follow-up QbTests on medication (2-4 weeks and 8-10 weeks later). In the control arm, participants will receive treatment as usual, with at least two follow-up consultations. Measures of parent-, teacher- and clinician-rated symptoms and global functioning will be completed at each time point. Health economic measures will be completed. Clinicians will record treatment decision-making. Acceptability and feasibility of the protocol will be assessed alongside outcome measure completion rates. Qualitative interviews will be conducted. The findings will be used to inform the development of a fully powered RCT. The results will be submitted for publication in peer-reviewed journals. The study has ethical approval. NCT03368573; Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Petousis, Panayiotis; Han, Simon X.; Aberle, Denise; Bui, Alex A.T.
2016-01-01
Introduction Identifying high-risk lung cancer individuals at an early disease stage is the most effective way of improving survival. The landmark National Lung Screening Trial (NLST) demonstrated the utility of low-dose computed tomography (LDCT) imaging to reduce mortality (relative to x-ray screening). As a result of the NLST and other studies, imaging-based lung cancer screening programs are now being implemented. However, LDCT interpretation results in a high number of false positives. A set of dynamic Bayesian networks (DBN) were designed and evaluated to provide insight into how longitudinal data can be used to help inform lung cancer screening decisions. Methods The LDCT arm of the NLST dataset was used to build and explore five DBNs for high-risk individuals. Three of these DBNs were built using a backward construction process, and two using structure learning methods. All models employ demographic, smoking status, cancer history, family lung cancer history, exposure risk factors, comorbidities related to lung cancer, and LDCT screening outcome information. Given the uncertainty arising from lung cancer screening, a cancer state-space model based on lung cancer staging was utilized to characterize the cancer status of an individual over time. The models were evaluated on balanced training and test sets of cancer and non-cancer cases to deal with data imbalance and overfitting. Results Results were comparable to expert decisions. The average area under the curve (AUC) of the receiver operating characteristic (ROC) for the three intervention points of the NLST trial was higher than 0.75 for all models. Evaluation of the models on the complete LDCT arm of the NLST dataset (N = 25, 486) demonstrated satisfactory generalization. Consensus of predictions over similar cases is reported in concordance statistics between the models’ and the physicians’ predictions. The models’ predictive ability with respect to missing data was also evaluated with the sample of cases that missed the second screening exam of the trial (N = 417). The DBNs outperformed comparison models such as logistic regression and naïve Bayes. Conclusion The lung cancer screening DBNs demonstrated high discrimination and predictive power with the majority of cancer and non-cancer cases. PMID:27664507
Graham, Amanda L; Papandonatos, George D; Cha, Sarah; Erar, Bahar; Amato, Michael S; Cobb, Nathan K; Niaura, Raymond S; Abrams, David B
2017-03-01
Web-based smoking cessation interventions can deliver evidence-based treatments to a wide swath of the population, but effectiveness is often limited by insufficient adherence to proven treatment components. This study evaluated the impact of a social network (SN) intervention and free nicotine replacement therapy (NRT) on adherence to evidence-based components of smoking cessation treatment in the context of a Web-based intervention. A sample of adult U.S. smokers (N = 5290) was recruited via BecomeAnEX.org, a free smoking cessation Web site. Smokers were randomized to one of four arms: (1) an interactive, evidence-based smoking cessation Web site (WEB) alone; (2) WEB in conjunction with an SN intervention designed to integrate participants into the online community (WEB+SN); (3) WEB plus free NRT (WEB+NRT); and (4) the combination of all treatments (WEB+SN+NRT). Adherence outcomes assessed at 3-month follow-up were as follows: Web site utilization metrics, use of skills training components, intratreatment social support, and pharmacotherapy use. WEB+SN+NRT outperformed all others on Web site utilization metrics, use of practical counseling tools, intratreatment social support, and NRT use. It was the only intervention to promote the sending of private messages and the viewing of community pages over WEB alone. Both social network arms outperformed WEB on most metrics of online community engagement. Both NRT arms showed higher medication use compared to WEB alone. This study demonstrated the effectiveness of two approaches for improving adherence to evidence-based components of smoking cessation treatment. Integrated approaches to medication provision and social network engagement can enhance adherence to components known to improve cessation. This study demonstrated that an integrated approach to medication provision and social network integration, when delivered through an online program, can enhance adherence across all three recommended components of an evidence-based smoking cessation program (skills training, social support, and pharmacotherapy use). Nicotine replacement therapy-when provided as part of an integrated program-increases adherence to other program elements, which in turn augment its own therapeutic effects. An explicit focus on approaches to improve treatment adherence is an important first step to identifying leverage points for optimizing intervention effectiveness. © The Author 2016. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Reinforcing the role of the conventional C-arm--a novel method for simplified distal interlocking.
Windolf, Markus; Schroeder, Josh; Fliri, Ladina; Dicht, Benno; Liebergall, Meir; Richards, R Geoff
2012-01-25
The common practice for insertion of distal locking screws of intramedullary nails is a freehand technique under fluoroscopic control. The process is technically demanding, time-consuming and afflicted to considerable radiation exposure of the patient and the surgical personnel. A new concept is introduced utilizing information from within conventional radiographic images to help accurately guide the surgeon to place the interlocking bolt into the interlocking hole. The newly developed technique was compared to conventional freehand in an operating room (OR) like setting on human cadaveric lower legs in terms of operating time and radiation exposure. The proposed concept (guided freehand), generally based on the freehand gold standard, additionally guides the surgeon by means of visible landmarks projected into the C-arm image. A computer program plans the correct drilling trajectory by processing the lens-shaped hole projections of the interlocking holes from a single image. Holes can be drilled by visually aligning the drill to the planned trajectory. Besides a conventional C-arm, no additional tracking or navigation equipment is required.Ten fresh frozen human below-knee specimens were instrumented with an Expert Tibial Nail (Synthes GmbH, Switzerland). The implants were distally locked by performing the newly proposed technique as well as the conventional freehand technique on each specimen. An orthopedic resident surgeon inserted four distal screws per procedure. Operating time, number of images and radiation time were recorded and statistically compared between interlocking techniques using non-parametric tests. A 58% reduction in number of taken images per screw was found for the guided freehand technique (7.4 ± 3.4) (mean ± SD) compared to the freehand technique (17.6 ± 10.3) (p < 0.001). Total radiation time (all 4 screws) was 55% lower for the guided freehand technique compared to conventional freehand (p = 0.001). Operating time per screw (from first shot to screw tightened) was on average 22% reduced by guided freehand (p = 0.018). In an experimental setting, the newly developed guided freehand technique for distal interlocking has proven to markedly reduce radiation exposure when compared to the conventional freehand technique. The method utilizes established clinical workflows and does not require cost intensive add-on devices or extensive training. The underlying principle carries potential to assist implant positioning in numerous other applications within orthopedics and trauma from screw insertions to placement of plates, nails or prostheses.
NASA Astrophysics Data System (ADS)
Troyan, D.
2016-12-01
The Atmospheric Radiation Measurement (ARM) program has been collecting data from instruments in diverse climate regions for nearly twenty-five years. These data are made available to all interested parties at no cost via specially designed tools found on the ARM website (www.arm.gov). Metadata is created and applied to the various datastreams to facilitate information retrieval using the ARM website, the ARM Data Discovery Tool, and data quality reporting tools. Over the last year, the Metadata Manager - a relatively new position within the ARM program - created two documents that summarize the state of ARM metadata processes: ARM Metadata Workflow, and ARM Metadata Standards. These documents serve as guides to the creation and management of ARM metadata. With many of ARM's data functions spread around the Department of Energy national laboratory complex and with many of the original architects of the metadata structure no longer working for ARM, there is increased importance on using these documents to resolve issues from data flow bottlenecks and inaccurate metadata to improving data discovery and organizing web pages. This presentation will provide some examples from the workflow and standards documents. The examples will illustrate the complexity of the ARM metadata processes and the efficiency by which the metadata team works towards achieving the goal of providing access to data collected under the auspices of the ARM program.
Yoon, Jiyeon; Park, Jinse; Park, Kunbo; Jo, Geunyeol; Kim, Haeyu; Jang, Wooyoung; Kim, Ji Sun; Youn, Jinyoung; Oh, Eung Seok; Kim, Hee-Tae; Youm, Chang Hong
2016-01-01
Recently, arm facilitation has been interested in gait rehabilitation. However, there have been few studies concerning arm facilitation in patients with Parkinson's disease (PD). The aim of our study was to investigate the effect of increasing arm weights on gait pattern in patients with PD. Twenty-seven patients with PD were enrolled, and they underwent gait analysis using a three-dimensional motion capture system. Sandbags were applied to the distal forearms in all participants. We compared gait parameters including arm swing, pelvic motion, spatiotemporal data, and relative rotational angle between the weighted and unweighted gaits. The total arm-swing amplitude and pelvic rotation were significantly higher when walking with additional arm weights than without arm weights. Cadence, walking speed, stride length, and swing phase were significantly higher, whereas stride time, double-support time, and stance phase were significantly lower, when walking with additional arm weights than without arm weights. We conclude that adding weights to the arm during walking may facilitate arm and pelvic movements, which results in changes to gait patterns. The therapeutic use of additional arm weights could be considered for gait rehabilitation in PD to improve gait impairment. Arm-swing facilitation using weight load improved gait in Parkinson's disease. Copyright © 2015 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
Arm blood flow and metabolism during arm and combined arm and leg exercise in humans
Volianitis, S; Secher, N H
2002-01-01
The cardiovascular response to exercise with several groups of skeletal muscle suggests that work with the arms may decrease leg blood flow. This study evaluated whether intense exercise with the legs would have a similar effect on arm blood flow (Q̇arm) and O2 consumption (V̇O2,arm). Ten healthy male subjects (age 21 ± 1 year; mean ± S.D.) performed arm cranking at 80 % of maximum arm work capacity (A trial) and combined arm cranking with cycling at 60 % of maximum leg work capacity (A + L trial). The combined trial was a maximum effort for 5-6 min. Q̇arm measurement by thermodilution in the axilliary vein and arterial and venous blood samples permitted calculation of V̇O2,arm. During the combined trial, Q̇arm was reduced by 0.58 ± 0.25 l min−1 (19.1 ± 3.0 %, P < 0.05) from the value during arm cranking (3.00 ± 0.46 l min−1). The arterio-venous O2 difference increased from 122 ± 15 ml l−1 during the arm trial to 150 ± 21 ml l−1 (P < 0.05) during the combined trial. Thus, V̇O2,arm (0.45 ± 0.06 l min−1) was reduced by 9.6 ± 6.3 % (P < 0.05) and arm vascular conductance from 27 ± 4 to 23 ± 3 ml min−1 (mmHg)−1 (P < 0.05) as noradrenaline spillover from the arm increased from 7.5 ± 3.5 to 13.8 ± 4.2 nmol min−1 (P < 0.05). The data suggest that during maximal whole body exercise in humans, arm vasoconstriction is established to an extent that affects oxygen delivery to and utilisation by working skeletal muscles. PMID:12411540
Palm, Peter; Gupta, Nidhi; Forsman, Mikael; Skotte, Jørgen; Nordquist, Tobias; Holtermann, Andreas
2018-06-26
Regarding prevention of neck and shoulder pain (NSP), unsupported arm elevation is one factor that should be taken into account when performing work risk assessment. Triaxial accelerometers can be used to measure arm elevation over several days but it is not possible to differentiate between supported and unsupported arm elevation from accelerometers only. Supported arm elevation is more likely to exist during sitting than standing. The aim of the study was to evaluate the use of whole workday measurements of arm elevation with accelerometers to assess potentially harmful work exposure of arm elevation, by comparing arm elevation at work with arm elevation during leisure, in a population with diverse work tasks, and to assess how the exposure parameters were modified when upper arm elevation during sitting time was excluded. The participants, 197 workers belonging to 12 occupational groups with diverse work tasks, wore triaxial accelerometers on the dominant arm, hip, and back for 1-4 days to measure arm elevation and periods of sitting. None of the groups were found to have higher exposure to arm elevation during work compared to leisure. Even though some occupations where known to have work tasks that forced them to work with elevated arms to a large extent. A high proportion of arm elevation derived from sitting time, especially so during leisure. When arm elevation during sitting time was excluded from the analysis, arm elevation was significantly higher at work than during leisure among construction workers, garbage collectors, manufacturing workers, and domestic cleaners. Together this illustrates that it is not suitable to use whole workday measurments of arm elevation with accelerometer as a sole information source when assessing the risk for NSP due to arm elevation. Information on body posture can provide relevant contextual information in exposure assessments when it is known that the potential harmful exposure is performed in standing or walking.
Naidoo, Kogieleum; Grobler, Anneke C; Deghaye, Nicola; Reddy, Tarylee; Gengiah, Santhanalakshmi; Gray, Andrew; Abdool Karim, Salim
2015-08-15
Initiation of antiretroviral therapy (ART) during tuberculosis (TB) treatment improves survival in TB-HIV coinfected patients. In patients with CD4 counts <50 cells per cubic millimeter, there is a substantial clinical and survival benefit of early ART initiation. The purpose of this study was to assess the costs and cost-effectiveness of starting ART at various time points during TB treatment in patients with CD4 counts ≥50 cells per cubic millimeter. In the SAPiT trial, 642 HIV-TB coinfected patients were randomized to 3 arms: receiving ART within 4 weeks of starting TB treatment (early treatment arm; Arm-1), after the intensive phase of TB treatment (late treatment arm; Arm-2), or after completing TB treatment (sequential arm; Arm-3). Direct health care costs were measured from a provider perspective using a micro-costing approach. The incremental cost per death averted was calculated using the trial outcomes. For patients with CD4 count ≥50 cells per cubic millimeter, median monthly variable costs per patient were US $116, US $113, and US $102 in Arm-1, Arm-2 and Arm-3, respectively. There were 12 deaths in 177 patients in Arm-1, 8 deaths in 180 patients in the Arm-2, and 19 deaths in 172 patients in Arm-3. Although the costs were lower in Arm-3, it had a substantially higher mortality rate. The incremental cost per death averted associated with moving from Arm-3 to Arm-2 was US $4199. There was no difference in mortality between Arm-1 and Arm-2, but Arm-1 was slightly more expensive. Initiation of ART after the completion of the intensive phase of TB treatment is cost-effective for patients with CD4 counts ≥50 cells per cubic millimeter.
CAT scan - arm; Computed axial tomography scan - arm; Computed tomography scan - arm; CT scan - arm ... Healing problems or scar tissue following surgery A CT scan may also be used to guide a surgeon ...
Changes in the bilateral pulse transit time difference with a moving arm.
Jiang, Xinge; Wei, Shoushui; Zheng, Dingchang; Huang, Peng; Liu, Chengyu
2018-04-20
Changes of pulse transit time (PTT) induced by arm position were studied for unilateral arm. However, consistency of the PTT changes was not validated for both arm sides. We aimed to quantify the PTT changes between horizontal and non-horizontal positions from right arm and left arm in order to explore the consistency of both arms. Twenty-four normal subjects aged between 21 and 50 (14 male and 10 female) years were enrolled. Left and right radial artery pulses were synchronously recorded from 24 healthy subjects with one arm (left or right) at five angles (90∘, 45∘, 0∘, -45∘ and -90∘) and the other arm at the horizontal level (0∘) for reference. The overall mean PTT changes at the five angles (from 90∘ to -90∘) in the left arm (right as reference) were 16.1, 12.3, -0.5, -2.5 and -2.6 ms, respectively, and in the right arm (left as reference) were 18.0, 12.6, 1.6, -1.6 and -2.0 ms, respectively. Obvious differences were not found in the PTT changes between the two arms (left arm moving or right arm moving) under each of the five different positions (all P> 0.05).
Octopus arm choice is strongly influenced by eye use.
Byrne, Ruth A; Kuba, Michael J; Meisel, Daniela V; Griebel, Ulrike; Mather, Jennifer A
2006-09-25
This study aims to investigate the octopus' eye and arm coordination and raises the question if visual guidance determines choice of arm use. Octopuses possess eight seemingly identical arms but have recently been reported to show a preference as to which arm they use to initiate contact with objects. These animals also exhibit lateralized eye use, therefore, a connection between eye and arm preference seems possible. Seven Octopus vulgaris were observed during approach, contact initiation and exploration of plastic objects that were positioned on three different levels in the water column. The subjects most commonly used an arm to initiate contact with an object that was in a direct line between the eye used to look at the object, and the object itself. This indicates that choice of arm use is spatially rather opportunistic when depending on visual guidance. Additionally, first contact with an object was usually established by the central third of the arm and in arm contact sequences neighboring arms were the most likely to follow an arm already touching the object. Although results point towards strong eye/arm coordination, we did not find lateralized behavior in this experiment. Results are discussed from a neuro-anatomical, behavioral and ecological perspective.
Lion, K Casey; Brown, Julie C; Ebel, Beth E; Klein, Eileen J; Strelitz, Bonnie; Gutman, Colleen Kays; Hencz, Patty; Fernandez, Juan; Mangione-Smith, Rita
2015-12-01
Consistent professional interpretation improves communication with patients who have limited English proficiency. Remote modalities (telephone and video) have the potential for wide dissemination. To test the effect of telephone vs. video interpretation on communication during pediatric emergency care. Randomized trial of telephone vs. video interpretation at a free-standing, university-affiliated pediatric emergency department (ED). A convenience sample of 290 Spanish-speaking parents of pediatric ED patients with limited English proficiency were approached from February 24 through August 16, 2014, of whom 249 (85.9%) enrolled; of these, 208 (83.5%) completed the follow-up survey (91 parents in the telephone arm and 117 in the video arm). Groups did not differ significantly by consent or survey completion rate, ED factors (eg, ED crowding), child factors (eg, triage level, medical complexity), or parent factors (eg, birth country, income). Investigators were blinded to the interpretation modality during outcome ascertainment. Intention-to-treat data were analyzed August 25 to October 20, 2014. Telephone or video interpretation for the ED visit, randomized by day. Parents were surveyed 1 to 7 days after the ED visit to assess communication and interpretation quality, frequency of lapses in interpreter use, and ability to name the child's diagnosis. Two blinded reviewers compared parent-reported and medical record-abstracted diagnoses and classified parent-reported diagnoses as correct, incorrect, or vague. Among 208 parents who completed the survey, those in the video arm were more likely to name the child's diagnosis correctly than those in the telephone arm (85 of 114 [74.6%] vs. 52 of 87 [59.8%]; P = .03) and less likely to report frequent lapses in interpreter use (2 of 117 [1.7%] vs. 7 of 91 [7.7%]; P = .04). No differences were found between the video and telephone arms in parent-reported quality of communication (101 of 116 [87.1%] vs. 74 of 89 [83.1%]; P = .43) or interpretation (58 of 116 [50.0%] vs. 42 of 89 [47.2%]; P = .69). Video interpretation was more costly (per-patient mean [SD] cost, $61 [$36] vs. $31 [$20]; P < .001). Parent-reported adherence to the assigned modality was higher for the video arm (106 of 114 [93.0%] vs .68 of 86 [79.1%]; P = .004). Families with limited English proficiency who received video interpretation were more likely to correctly name the child's diagnosis and had fewer lapses in interpreter use. Use of video interpretation shows promise for improving communication and patient care in this population. clinicaltrials.gov Identifier: NCT01986179.
Performance and Kinematics of Various Throwing Techniques in Team-Handball
Wagner, Herbert; Pfusterschmied, Jürgen; von Duvillard, Serge P.; Müller, Erich
2011-01-01
In team-handball competition, the players utilize various throwing techniques that differ in the lower body movements (with and without run-up or jump). These different lower body movements influence changes in the upper body movements and thus also affect the performance. A comprehensive analysis of 3D-kinematics of team-handball throws that may explain these differences in performance is lacking. Consequently, the purpose of this study was (1) to compare performance (ball velocity and throwing accuracy) between the jump throw, standing throw with and without run-up, and the pivot throw; (2) to calculate the influence of kinematic parameters to ball velocity; and (3) to determine if these four throwing techniques differ significantly in kinematics. Three-dimensional kinematic data (angles, angular velocities and their timing, ball velocity and velocity of the center of mass) of 14 elite team-handball players were measured using an 8 camera Vicon MX13 motion capture system (Vicon, Oxford, UK), at 250 Hz. Significant difference was found between the four throwing techniques for ball velocity (p < 0. 001), maximal velocity of the center of mass in goal-directed movement (p < 0.001), and 15 additional kinematic variables (p < 0.003). Ball velocity was significant impacted by the run-up and the pelvis and trunk movements. Depending on floor contact (standing vs. jump throws), elite players in the study used two different strategies (lead leg braces the body vs. opposed leg movements during flight) to accelerate the pelvis and trunk to yield differences in ball velocity. However, these players were able to utilize the throwing arm similarly in all four throwing techniques. Key points Elite team-handball players achieved the greatest ball velocity in the standing throw with run-up (100%), followed by the standing throw without run-up (93%), jump throw (92%) and pivot throw (85%). Depending on the floor contact (standing vs. jump throws) the elite players of the study used two different strategies (lead leg braces the body vs. opposed leg movements during flight) to accelerate the pelvis and trunk that caused differences in ball velocity. Elite team-handball players were able to utilize the throwing arm similarly in all four throwing techniques. PMID:24149298
A software toolbox for robotics
NASA Technical Reports Server (NTRS)
Sanwal, J. C.
1985-01-01
A method for programming cooperating manipulators, which is guided by a geometric description of the task to be performed, is given. For this a suitable language must be used and a method for describing the workplace and the objects in it in geometric terms. A task level command language and its implementation for concurrently driven multiple robot arm is described. The language is suitable for driving a cell in which manipulators, end effectors, and sensors are controlled by their own dedicated processors. These processors can communicate with each other through a communication network. A mechanism for keeping track of the history of the commands already executed allows the command language for the manipulators to be event driven. A frame based world modeling system is utilized to describe the objects in the work environment and any relationships that hold between these objects. This system provides a versatile tool for managing information about the world model. Default actions normally needed are invoked when the data base is updated or accessed. Most of the first level error recovery is also invoked by the database by utilizing the concepts of demons. The package can be utilized to generate task level commands in a problem solver or a planner.
Cripe, Timothy P; Chen, Chun-Yu; Denton, Nicholas L; Haworth, Kellie B; Hutzen, Brian; Leddon, Jennifer L; Streby, Keri A; Wang, Pin-Yi; Markert, James M; Waters, Alicia M; Gillespie, George Yancey; Beierle, Elizabeth A; Friedman, Gregory K
2015-01-01
Progress for improving outcomes in pediatric patients with solid tumors remains slow. In addition, currently available therapies are fraught with numerous side effects, often causing significant life-long morbidity for long-term survivors. The use of viruses to kill tumor cells based on their increased vulnerability to infection is gaining traction, with several viruses moving through early and advanced phase clinical testing. The prospect of increased efficacy and decreased toxicity with these agents is thus attractive for pediatric cancer. In part I of this two-part review, we focus on strategies for utilizing oncolytic engineered herpes simplex virus (HSV) to target pediatric malignancies. We discuss mechanisms of action, routes of delivery, and the role of preexisting immunity on antitumor efficacy. Challenges to maximizing oncolytic HSV in children are examined, and we highlight how these may be overcome through various arming strategies. We review the preclinical and clinical evidence demonstrating safety of a variety of oncolytic HSVs. In Part II, we focus on the antitumor efficacy of oncolytic HSV in pediatric tumor types, pediatric clinical advances made to date, and future prospects for utilizing HSV in pediatric patients with solid tumors. PMID:26436135
Robotic-Movement Payload Lifter and Manipulator
NASA Technical Reports Server (NTRS)
Doggett, William R. (Inventor); King, Bruce D. (Inventor); Collins, Timothy J. (Inventor); Dorsey, John T. (Inventor)
2011-01-01
A payload lifter/manipulator module includes a rotatable joint supporting spreader arms angularly spaced with respect to one another. A rigid arm is fixedly coupled to the joint and extends out therefrom to a tip. A tension arm has a first end and a second end with the first end being fixedly coupled to the tip of the rigid arm. The tension arm incorporates pivots along the length thereof. Each pivot can be engaged by or disengaged from the outboard end of a spreader arm based on a position of the spreader arm. A hoist, positioned remotely with respect to the module and coupled to the second end of the tension arm, controls the position of the spreader arms to thereby control the position of the rigid arm's tip. Payload lifter/manipulator assemblies can be constructed with one or more of the modules.
NASA Astrophysics Data System (ADS)
Brekke, Stewart
2013-04-01
All galaxies began as spiral galaxies. The early universe began with sets of two or more pre-galactic arms orbiting each other. As gravitational attraction between the arms took effect, the fore-sections of the arms tangentially collided forming spiral galaxies when they attached with the orbital motion of the arms being converted to the rotational motion of the newly formed spiral galaxies or (Iφ)arm1+ (Iφ)arm2+ ...+ (Iφ)armn= (Iφ)galaxy. If the centripetal force on the arms is more than the gravitational force on the arms, the spiral galaxy remains a spiral galaxy i.e. mv^2/r>=Gmarmmgalaxy/r^2. If the galaxy is slowly rotating, the spiral arms collapse into the body of the galaxy because the gravitational force is greater than the centripetal force on the arms and an elliptical galaxy is formed i.e. mv^2/r < Gmarmsmgalaxy/r^2.
Relationship between input power and power density of SMA spring
NASA Astrophysics Data System (ADS)
Park, Cheol Hoon; Ham, Sang Yong; Son, Young Su
2016-04-01
The important required characteristics of an artificial muscle for a human arm-like manipulator are high strain and high power density. From this viewpoint, an SMA (shape memory alloy) spring is a good candidate for the actuator of a robotic manipulator that utilizes an artificial muscle. In this study, the maximum power density of an SMA spring was evaluated with respect to the input power. The spring samples were fabricated from SMA wires of different diameters ranging between 0.1 and 0.3 mm. For each diameter, two types of wires with different transition temperatures were used. The relationship between the transition temperature and maximum power density was also evaluated. Each SMA spring was stretched downward by an attached weight and the temperature was increased through the application of an electric current. The displacement, velocity, and temperature of the SMA spring were measured by laser displacement sensors and a thermocouple. Based on the experimental data, it was determined that the maximum power densities of the different SMA springs ranged between 1,300 and 5,500 W/kg. This confirmed the applicability of an SMA spring to human arm-like robotic manipulators. The results of this study can be used as reference for design.
Chen, Weihai; Cui, Xiang; Zhang, Jianbin; Wang, Jianhua
2015-06-01
Rehabilitation technologies have great potentials in assisted motion training for stroke patients. Considering that wrist motion plays an important role in arm dexterous manipulation of activities of daily living, this paper focuses on developing a cable-driven wrist robotic rehabilitator (CDWRR) for motion training or assistance to subjects with motor disabilities. The CDWRR utilizes the wrist skeletal joints and arm segments as the supporting structure and takes advantage of cable-driven parallel design to build the system, which brings the properties of flexibility, low-cost, and low-weight. The controller of the CDWRR is designed typically based on a virtual torque-field, which is to plan "assist-as-needed" torques for the spherical motion of wrist responding to the orientation deviation in wrist motion training. The torque-field controller can be customized to different levels of rehabilitation training requirements by tuning the field parameters. Additionally, a rapidly convergent parameter self-identification algorithm is developed to obtain the uncertain parameters automatically for the floating wearable structure of the CDWRR. Finally, experiments on a healthy subject are carried out to demonstrate the performance of the controller and the feasibility of the CDWRR on wrist motion training or assistance.
The application of neural networks to myoelectric signal analysis: a preliminary study.
Kelly, M F; Parker, P A; Scott, R N
1990-03-01
Two neural network implementations are applied to myoelectric signal (MES) analysis tasks. The motivation behind this research is to explore more reliable methods of deriving control for multidegree of freedom arm prostheses. A discrete Hopfield network is used to calculate the time series parameters for a moving average MES model. It is demonstrated that the Hopfield network is capable of generating the same time series parameters as those produced by the conventional sequential least squares (SLS) algorithm. Furthermore, it can be extended to applications utilizing larger amounts of data, and possibly to higher order time series models, without significant degradation in computational efficiency. The second neural network implementation involves using a two-layer perceptron for classifying a single site MES based on two features, specifically the first time series parameter, and the signal power. Using these features, the perceptron is trained to distinguish between four separate arm functions. The two-dimensional decision boundaries used by the perceptron classifier are delineated. It is also demonstrated that the perceptron is able to rapidly compensate for variations when new data are incorporated into the training set. This adaptive quality suggests that perceptrons may provide a useful tool for future MES analysis.
Novel system for automatic measuring diopter based on ARM circuit block
NASA Astrophysics Data System (ADS)
Xue, Feng; Zhong, Lei; Chen, Zhe; Xue, Deng-pan; Li, Xiang-ning
2009-07-01
Traditional commercial instruments utilized in vision screening programs cannot satisfy the request for real-time diopter measurement by far, and their success is limited by some defectiveness such as computer-attached, clumsy volume, and low accuracy of parameters measured, etc. In addition, astigmatic eyes cannot be determined in many devices. This paper proposes a new design of diopter measurement system based on SAMSUNG's ARM9 circuit block. There are several contributions in the design. The new developed system has not only the function of automatically measuring diopter, but also the advantages of the low cost, and especially the simplicity and portability. Besides, by placing point sources in three directions, the instrument can determine astigmatic eyes at the same time. Most of the details are introduced as the integrated design of measuring system, interface circuit of embedded system and so on. Through a preliminary experiment, it is proved that the system keeps good feasibility and validity. The maximum deviation of measurement result is 0.344D.The experimental results also demonstrate the system can provide the service needed for real-time applications. The instrument present here is expected to be widely applied in many fields such as the clinic and home healthcare.
Finch, Peter
2017-06-01
Intra-abdominal fat is an important factor in determining the metabolic syndrome/insulin resistance, and thus the risk of diabetes and ischaemic heart disease. Computed Tomography (CT) fat segmentation represents a defined method of quantifying intra-abdominal fat, with attendant radiation risks. Bioimpedance spectroscopy may offer a method of assessment without any risks to the patients. A comparison is made of these two methods. This was a preliminary study of the utility of multifrequency bioimpedance spectroscopy of the mid abdomen as a measure of intra-abdominal fat, by comparison with fat segmentation of an abdominal CT scan in the -30 to -190 HU range. There was a significant (P < 0.01) correlation between intra-abdominal fat and mid-upper arm circumference, as well as the bioimpedance parameter, the R/S ratio. Multivariate analysis showed that these were the only independant variables and allowed the derivation of a formula to estimate intra-abdominal fat: IAF = 0.02 × MAC - 0.757 × R/S + 0.036. Circumabdominal bioimpedance spectroscopy may prove a useful method of assessing intra-abdominal fat, and may be suitable for use in studies to enhance other measures of body composition, such as mid-upper arm circumference.
Bilateral control in teleoperation of a rehabilitation robot
NASA Astrophysics Data System (ADS)
Rahman, Tariq; Harwin, William S.
1993-03-01
One applications of teleoperation principles is of a manipulator that might be used to augment function in a disabled person. An individual with a paralyzing injury may have complete loss of motor and sensory function in his or her arms, which limits his or her ability to interact with the environment and perform simple tasks such as feeding or turning pages. One way of enhancing functionality is to employ a telemanipulator that might take the place of a care giver, thus providing the person with increased independence. This paper describes how a high level spinal cord injured individual would use head movement to control a robot. It is felt that the key to successful manipulation is in attaining a sense of force and position proprioception. This natural proprioception exists in cable operated prosthetic arms and simple tools such as mouthsticks or laser beam pointers where the user is physically linked to the device. This sense of proprioception is being emulated using a head controlled master-slave arrangement. The goal is for the disabled individual to operate a manipulator and utilize proprioceptive as well as visual feedback. This would lessen the mental burden on the user and ultimately make the device more acceptable.
Probing the molecular design of hyper-branched aryl polyesters towards lubricant applications
NASA Astrophysics Data System (ADS)
Robinson, Joshua W.; Zhou, Yan; Bhattacharya, Priyanka; Erck, Robert; Qu, Jun; Bays, J. Timothy; Cosimbescu, Lelia
2016-01-01
We report novel polymeric materials that may be used as viscosity index improvers (VII) for lubricant applications. Our efforts included probing the comb-burst hyper-branched aryl polyester architecture for beneficial viscosity and friction behavior when utilized as an additive in a group I oil. The monomer was designed as to undergo polymerization via polycondensation within the architectural construct (AB2), typical of hyperbranched polymers. The monomer design was comprised of aliphatic arms (12 or 16 methylenes) to provide the necessary lipophilicity to achieve solubility in a non-polar medium. Once polymerized, via catalyst and heat, the surface alcohols were functionalized with fatty acids (lauric and palmitic). Controlling the aliphatic nature of the internal arms and peripheral end-groups provided four unique flexible polymer designs. Changing the reaction time and concentration provided opportunities to investigate the influence of molecular weight and branching density on oil-solubility, viscosity, and friction. Oil-solubility was found to decrease with fewer internal carbons, but the number of internal carbons appears to have little influence on the bulk solution viscosity. At concentrations of 2 wt % in a group I base oil, these polymer additives demonstrated an improved viscosity index and reduced friction coefficient, validating the basic approach.
Off-axis low coherence digital holographic interferometry for quantitative phase imaging with an LED
NASA Astrophysics Data System (ADS)
Guo, Rongli; Wang, Fan; Hu, Xiaoying; Yang, Wenqian
2017-11-01
Off-axis digital holographic interferometry with the light source of a light emitting diode (LED) is presented and its application for quantitative phase imaging in a large range with low noise is demonstrated. The scheme is implemented in a grating based Mach-Zehnder interferometer. To achieve off-axis interferometry, firstly, the collimated beam emitted from an LED is diffracted into multiple orders by a grating and they are split into two copies by a beam splitter; secondly, in the object arm the zero order of one copy is filtered in the Fourier plane and is reshaped to illuminate the sample, while in the reference arm one of its first order of another copy is selected to serve as the reference beam, and then an off-axis hologram can be obtained at the image plane. The main advantage stemming from an LED illumination is its high spatial phase resolution, due to the subdued speckle effect. The off-axis geometry enables one-shot recording of the hologram in the millisecond scale. The utility of the proposed setup is illustrated with measurements of a resolution target and part of a wing of green-lacewing, and dynamic evaporation process of an ethanol film.
Reassessing the improbability of a muscular crinoid stem
Gorzelak, Przemysław; Głuchowski, Edward; Salamon, Mariusz A.
2014-01-01
Muscular articulations in modern stalked crinoids are only present in the arms. Although it has been suggested that certain coiled-stemmed fossil taxa may have been functionally adapted to utilize muscles, evidence supporting this interpretation is lacking. Here, we use cathodoluminescence and SEM to reveal the skeletal microstructure of the enigmatic coiled-stemmed taxon Ammonicrinus (Flexibilia). Based on the well-established link between skeletal microstructure and the nature of infilling soft tissues in modern echinoderms, we reconstructed the palaeoanatomy of the Middle Devonian ammonicrinids. We show that their median columnals with elongated lateral columnal enclosure extensions (LCEE) have stereom microstructure unexpectedly resembling that in the crinoid muscular arm plates. In particular, large ligamentary facets, that are present on each side of a transverse ridge, are mainly comprised of fine galleried stereom that is indicative of the mutable collagenous tissues. In contrast, fine labyrinthic stereom, commonly associated with muscles, is situated in the periphery on each side of the surface of elongated LCEE. Our findings thus strongly suggest that the muscles may have also been present in the stem of ammonicrinids. These results reassess the previous hypotheses about evolution of muscles in crinoids and provide new insights into the mode of life of Ammonicrinus. PMID:25116414
NASA Technical Reports Server (NTRS)
Kutepov, A. A.; Feofilov, A. G.; Manuilova, R. O.; Yankovsky, V. A.; Rezac, L.; Pesnell, W. D.; Goldberg, R. A.
2008-01-01
The Accelerated Lambda Iteration (ALI) technique was developed in stellar astrophysics at the beginning of 1990s for solving the non-LTE radiative transfer problem in atomic lines and multiplets in stellar atmospheres. It was later successfully applied to modeling the non-LTE emissions and radiative cooling/heating in the vibrational-rotational bands of molecules in planetary atmospheres. Similar to the standard lambda iterations ALI operates with the matrices of minimal dimension. However, it provides higher convergence rate and stability due to removing from the iterating process the photons trapped in the optically thick line cores. In the current ALI-ARMS (ALI for Atmospheric Radiation and Molecular Spectra) code version additional acceleration of calculations is provided by utilizing the opacity distribution function (ODF) approach and "decoupling". The former allows replacing the band branches by single lines of special shape, whereas the latter treats non-linearity caused by strong near-resonant vibration-vibrational level coupling without additional linearizing the statistical equilibrium equations. Latest code application for the non-LTE diagnostics of the molecular band emissions of Earth's and Martian atmospheres as well as for the non-LTE IR cooling/heating calculations are discussed.
Reassessing the improbability of a muscular crinoid stem
NASA Astrophysics Data System (ADS)
Gorzelak, Przemysław; Głuchowski, Edward; Salamon, Mariusz A.
2014-08-01
Muscular articulations in modern stalked crinoids are only present in the arms. Although it has been suggested that certain coiled-stemmed fossil taxa may have been functionally adapted to utilize muscles, evidence supporting this interpretation is lacking. Here, we use cathodoluminescence and SEM to reveal the skeletal microstructure of the enigmatic coiled-stemmed taxon Ammonicrinus (Flexibilia). Based on the well-established link between skeletal microstructure and the nature of infilling soft tissues in modern echinoderms, we reconstructed the palaeoanatomy of the Middle Devonian ammonicrinids. We show that their median columnals with elongated lateral columnal enclosure extensions (LCEE) have stereom microstructure unexpectedly resembling that in the crinoid muscular arm plates. In particular, large ligamentary facets, that are present on each side of a transverse ridge, are mainly comprised of fine galleried stereom that is indicative of the mutable collagenous tissues. In contrast, fine labyrinthic stereom, commonly associated with muscles, is situated in the periphery on each side of the surface of elongated LCEE. Our findings thus strongly suggest that the muscles may have also been present in the stem of ammonicrinids. These results reassess the previous hypotheses about evolution of muscles in crinoids and provide new insights into the mode of life of Ammonicrinus.
Independent Orbiter Assessment (IOA): Analysis of the remote manipulator system
NASA Technical Reports Server (NTRS)
Tangorra, F.; Grasmeder, R. F.; Montgomery, A. D.
1987-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items (PCIs). To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The independent analysis results for the Orbiter Remote Manipulator System (RMS) are documented. The RMS hardware and software are primarily required for deploying and/or retrieving up to five payloads during a single mission, capture and retrieve free-flying payloads, and for performing Manipulator Foot Restraint operations. Specifically, the RMS hardware consists of the following components: end effector; displays and controls; manipulator controller interface unit; arm based electronics; and the arm. The IOA analysis process utilized available RMS hardware drawings, schematics and documents for defining hardware assemblies, components and hardware items. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. Of the 574 failure modes analyzed, 413 were determined to be PCIs.
Does Muscular Force of the Upper Body Increase Following Acute, Direct Vibration?
Cochrane, D J
2016-06-01
The aim of the current study was to examine the acute effect of direct vibration has on bicep curl force-generating capacity. 11 healthy team and individual sport-trained males performed right and left DB bicep curl at 50% of 1 RM where peak force (PF), mean force (MF), rate of force development (RFD) and electromyography (EMG) were assessed during the concentric phase before and immediately after direct vibration. Using new vibration technology utilizing a pulsing frequency (0-170 Hz) each arm was randomly assigned to receive either 10 min of direct vibration or control (no vibration). Following direct vibration PF increased 6.6±4.5 N (difference pre-post±90 CL; p>0.05) compared to control FP (-1.2±65 N; p>0.05) however, this was not significant. Furthermore, there were no other significant changes (p>0.05) in MP, RFD and EMG between vibration and control arms. This is in agreement with other research that has reported that acute strength changes from vibration elicits negligible changes, however it appears that there are no detrimental effects of using this new vibration device. © Georg Thieme Verlag KG Stuttgart · New York.
Leidl, R; Jacobi, E; Knab, J; Schweikert, B
2006-04-01
Economic assessment of an additional psychological intervention in the rehabilitation of patients with chronic low-back pain and evaluation of results by decision makers. Piggy-back cost-utility analysis of a randomised clinical trial, including a bootstrap analysis. Costs were measured by using the cost accounting systems of the rehabilitation clinics and by surveying patients. Health-related quality of life was measured using the EQ-5D. Implications of different representations of the decision problem and corresponding decision rules concerning the cost-effectiveness plane are discussed. As compared with the 126 patients of the control arm, the 98 patients in the intervention arm gained 3.5 days in perfect health on average as well as 1219 euro cost saving. However, because of the uncertainty involved, the results of a bootstrap analysis cover all quadrants of the cost-effectiveness plane. Using maximum willingness-to-pay per effect unit gained, decision rules can be defined for parts of the cost-effectiveness plane. These have to be aggregated in a further valuation step. Study results show that decisions on stochastic economic evaluation results may require an additional valuation step aggregating the various parts of the cost-effectiveness plane.
Probing the Circumstellar Disks of Be Stars with Contemporaneous Optical and IR Spectroscopy
NASA Astrophysics Data System (ADS)
Bjorkman, Karen S.; Hesselbach, E. N.; Wisniewski, J. P.; Bjorkman, J. E.
2006-12-01
Asymmetric double-peaked hydrogen emission line profiles in classical Be stars have been interpreted as evidence of one-armed density waves in the circumstellar disks. Contemporaneous optical and IR spectroscopy can aid in mapping the density structure of these one-armed waves as a function of radius. Furthermore, variability has been detected in these stars over both short (days to weeks) and longer (months) time-scales. We present preliminary results from contemporaneous Ritter Observatory (Hα) and IRTF SpeX (0.8-5.4 μm) spectroscopy of 16 classical Be stars observed in September 2005 and January 2006. The data illustrate a range of line profiles common in Be stars and show significant variability. These observations are the first of a larger project to utilize combined optical and IR data to investigate the physical details of these circumstellar disks. This research has been supported in part by a NASA GSRP fellowship to JPW, a NASA LTSA grant to KSB, and an NSF grant to JEB. We thank the NASA IRTF for observing time allocations and support. We thank the Ritter observing team, and especially Nancy Morrison, for crucial assistance with the supporting optical observations.
NASA Astrophysics Data System (ADS)
Chen, Weihai; Cui, Xiang; Zhang, Jianbin; Wang, Jianhua
2015-06-01
Rehabilitation technologies have great potentials in assisted motion training for stroke patients. Considering that wrist motion plays an important role in arm dexterous manipulation of activities of daily living, this paper focuses on developing a cable-driven wrist robotic rehabilitator (CDWRR) for motion training or assistance to subjects with motor disabilities. The CDWRR utilizes the wrist skeletal joints and arm segments as the supporting structure and takes advantage of cable-driven parallel design to build the system, which brings the properties of flexibility, low-cost, and low-weight. The controller of the CDWRR is designed typically based on a virtual torque-field, which is to plan "assist-as-needed" torques for the spherical motion of wrist responding to the orientation deviation in wrist motion training. The torque-field controller can be customized to different levels of rehabilitation training requirements by tuning the field parameters. Additionally, a rapidly convergent parameter self-identification algorithm is developed to obtain the uncertain parameters automatically for the floating wearable structure of the CDWRR. Finally, experiments on a healthy subject are carried out to demonstrate the performance of the controller and the feasibility of the CDWRR on wrist motion training or assistance.
Readout Electronics for the Forward Vertex Detector at PHENIX
NASA Astrophysics Data System (ADS)
Phillips, Michael
2010-11-01
The PHENIX experiment at RHIC at Brookhaven National Laboratory has been providing high quality physics data for over 10 years. The current PHENIX physics program will be significantly enhanced by addition of the Forward Silicon Vertex upgrade detector (FVTX) in the acceptance of existing muon arm detectors. The proposed tracker is planned to be put into operation in 2012. Each arm of the FVTX detector consist of 4 discs of silicon strip sensors combined with FPHX readout chips, designed at FNAL. The full detector consists of over 1 million active mini-strip channels with instantaneous bandwidth topping 3.4 Tb/s. The FPHX chip utilizes data push architecture with 2 serial output streams at 200 MHz. The readout electronics design consists of Read-Out Cards (ROC) located in the vicinity of the detector and Front End Modules (FEM) located in the Counting House. ROC boards combine the data from several chips, synchronizes data streams and send them to FEM over a Fiber Optics Link. The data are buffered in the FEM and then sent to a standard PHENIX DAQ interface upon Level-1 trigger request. We will present the current status of the readout electronics development and testing, including tests with data from production wedges.
Cortical Spiking Network Interfaced with Virtual Musculoskeletal Arm and Robotic Arm
Dura-Bernal, Salvador; Zhou, Xianlian; Neymotin, Samuel A.; Przekwas, Andrzej; Francis, Joseph T.; Lytton, William W.
2015-01-01
Embedding computational models in the physical world is a critical step towards constraining their behavior and building practical applications. Here we aim to drive a realistic musculoskeletal arm model using a biomimetic cortical spiking model, and make a robot arm reproduce the same trajectories in real time. Our cortical model consisted of a 3-layered cortex, composed of several hundred spiking model-neurons, which display physiologically realistic dynamics. We interconnected the cortical model to a two-joint musculoskeletal model of a human arm, with realistic anatomical and biomechanical properties. The virtual arm received muscle excitations from the neuronal model, and fed back proprioceptive information, forming a closed-loop system. The cortical model was trained using spike timing-dependent reinforcement learning to drive the virtual arm in a 2D reaching task. Limb position was used to simultaneously control a robot arm using an improved network interface. Virtual arm muscle activations responded to motoneuron firing rates, with virtual arm muscles lengths encoded via population coding in the proprioceptive population. After training, the virtual arm performed reaching movements which were smoother and more realistic than those obtained using a simplistic arm model. This system provided access to both spiking network properties and to arm biophysical properties, including muscle forces. The use of a musculoskeletal virtual arm and the improved control system allowed the robot arm to perform movements which were smoother than those reported in our previous paper using a simplistic arm. This work provides a novel approach consisting of bidirectionally connecting a cortical model to a realistic virtual arm, and using the system output to drive a robotic arm in real time. Our techniques are applicable to the future development of brain neuroprosthetic control systems, and may enable enhanced brain-machine interfaces with the possibility for finer control of limb prosthetics. PMID:26635598
Guillou, Marie; Maurel, Blandine; Necib, Hatem; Vent, Pierre-Alexandre; Costargent, Alain; Chaillou, Philippe; Gouëffic, Yann; Kaladji, Adrien
2018-02-01
Flat-panel detectors on mobile C-arm (MC-arm) systems are currently challenging fixed C-arm (FC-arm) systems used in hybrid operating rooms. MC-arm systems offer an alternative to FC-arm systems in the endovascular treatment of peripheral arterial disease (PAD) but their efficiency has not been evaluated comparatively. Two series of patients undergoing arteriography with intention to treat were included. Each series consisted of 2 nonrandomized groups: an MC-arm group and an FC-arm group. Series 1 evaluated exposure to the patient (MC-arm, n = 113; FC-arm, n = 206) while series 2 evaluated exposure to patients and also health care personnel (MC-arm, n = 24; FC-arm, n = 76). The primary end points for evaluating exposure were air kerma (AK, in mGy) for patients and effective dose for health care personnel (in μSv). After adjustment for the effect of body mass index (analysis of covariance test), AK was found to be lower in the MC-arm group than in the FC-arm group (124.1 ± 142 vs. 173.3 ± 248.7, P = 0.025). There was no difference between the groups with regard to effective dose recorded for senior surgeons or for operating room nurses. However, a higher effective dose was recorded by the MC-arm group external dosimeter for the trainee resident and for nurse anesthetists. In endovascular treatment of lower limb PAD, use of an FC-arm system is associated with more radiation exposure to the patient than an MC-arm system. However, this type of imaging system does not appear to affect exposure to health care personnel. Copyright © 2017 Elsevier Inc. All rights reserved.
Effect of arm swing strategy on local dynamic stability of human gait.
Punt, Michiel; Bruijn, Sjoerd M; Wittink, Harriet; van Dieën, Jaap H
2015-02-01
Falling causes long term disability and can even lead to death. Most falls occur during gait. Therefore improving gait stability might be beneficial for people at risk of falling. Recently arm swing has been shown to influence gait stability. However at present it remains unknown which mode of arm swing creates the most stable gait. To examine how different modes of arm swing affect gait stability. Ten healthy young male subjects volunteered for this study. All subjects walked with four different arm swing instructions at seven different gait speeds. The Xsens motion capture suit was used to capture gait kinematics. Basic gait parameters, variability and stability measures were calculated. We found an increased stability in the medio-lateral direction with excessive arm swing in comparison to normal arm swing at all gait speeds. Moreover, excessive arm swing increased stability in the anterior-posterior and vertical direction at low gait speeds. Ipsilateral and inphase arm swing did not differ compared to a normal arm swing. Excessive arm swing is a promising gait manipulation to improve local dynamic stability. For excessive arm swing in the ML direction there appears to be converging evidence. The effect of excessive arm swing on more clinically relevant groups like the more fall prone elderly or stroke survivors is worth further investigating. Excessive arm swing significantly increases local dynamic stability of human gait. Copyright © 2014 Elsevier B.V. All rights reserved.
31 CFR 543.301 - Arms or any related materiel.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 31 Money and Finance:Treasury 3 2013-07-01 2013-07-01 false Arms or any related materiel. 543.301... Definitions § 543.301 Arms or any related materiel. The term arms or any related materiel means arms or... of arms and related materiel and technical training and assistance intended solely for support of or...
31 CFR 543.301 - Arms or any related materiel.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 31 Money and Finance:Treasury 3 2014-07-01 2014-07-01 false Arms or any related materiel. 543.301... Definitions § 543.301 Arms or any related materiel. The term arms or any related materiel means arms or... of arms and related materiel and technical training and assistance intended solely for support of or...
31 CFR 543.301 - Arms or any related materiel.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 31 Money and Finance:Treasury 3 2012-07-01 2012-07-01 false Arms or any related materiel. 543.301... Definitions § 543.301 Arms or any related materiel. The term arms or any related materiel means arms or... of arms and related materiel and technical training and assistance intended solely for support of or...
31 CFR 543.301 - Arms or any related materiel.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 31 Money and Finance:Treasury 3 2011-07-01 2011-07-01 false Arms or any related materiel. 543.301... Definitions § 543.301 Arms or any related materiel. The term arms or any related materiel means arms or... of arms and related materiel and technical training and assistance intended solely for support of or...
Dual redundant arm system operational quality measures and their applications - Static measures
NASA Technical Reports Server (NTRS)
Lee, Sukhan; Kim, Sungbok
1990-01-01
The authors present dual-arm system static operational quality measures which quantify the efficiency and capability of a dual-arm system in generating Cartesian velocities and static forces. First, they define and analyze the kinematic interactions between the two arms incurred by the various modes of dual-arm cooperation, such as transport, assembly, and grasping modes of cooperation, and specify the kinematic constraints imposed on individual arms in Cartesian space due to the kinematic interactions. Dual-arm static manipulability is presented. Finally, dual-arm operational quality is scaled by a task-oriented operational quality measure (TOQs) obtained by the comparison between the desired and actual static manipulabilities. TOQs is used in the optimization of dual-arm joint configurations. Simulation results are shown.
NASA Astrophysics Data System (ADS)
Mortensen, Kell; Borger, Anine L.; Kirkensgaard, Jacob J. K.; Garvey, Christopher J.; Almdal, Kristoffer; Dorokhin, Andriy; Huang, Qian; Hassager, Ole
2018-05-01
We present structural small-angle neutron scattering studies of a three-armed polystyrene star polymer with short deuterated segments at the end of each arm. We show that the form factor of the three-armed star molecules in the relaxed state agrees with that of the random phase approximation of Gaussian chains. Upon exposure to large extensional flow conditions, the star polymers change conformation resulting in a highly stretched structure that mimics a fully extended three-armed tube model. All three arms are parallel to the flow, one arm being either in positive or negative stretching direction, while the two other arms are oriented parallel, right next to each other in the direction opposite to the first arm.
Su, Alvin W; McIntosh, Amy L; Schueler, Beth A; Milbrandt, Todd A; Winkler, Jennifer A; Stans, Anthony A; Larson, A Noelle
Intraoperative C-arm fluoroscopy and low-dose O-arm are both reasonable means to assist in screw placement for idiopathic scoliosis surgery. Both using pediatric low-dose O-arm settings and minimizing the number of radiographs during C-arm fluoroscopy guidance decrease patient radiation exposure and its deleterious biological effect that may be associated with cancer risk. We hypothesized that the radiation dose for C-arm-guided fluoroscopy is no less than low-dose O-arm scanning for placement of pedicle screws. A multicenter matched-control cohort study of 28 patients in total was conducted. Fourteen patients who underwent O-arm-guided pedicle screw insertion for spinal fusion surgery in 1 institution were matched to another 14 patients who underwent C-arm fluoroscopy guidance in the other institution in terms of the age of surgery, body weight, and number of imaged spine levels. The total effective dose was compared. A low-dose pediatric protocol was used for all O-arm scans with an effective dose of 0.65 mSv per scan. The effective dose of C-arm fluoroscopy was determined using anthropomorphic phantoms that represented the thoracic and lumbar spine in anteroposterior and lateral views, respectively. The clinical outcome and complications of all patients were documented. The mean total effective dose for the O-arm group was approximately 4 times higher than that of the C-arm group (P<0.0001). The effective dose for the C-arm patients had high variability based on fluoroscopy time and did not correlate with the number of imaged spine levels or body weight. The effective dose of 1 low-dose pediatric O-arm scan approximated 85 seconds of the C-arm fluoroscopy time. All patients had satisfactory clinical outcomes without major complications that required returning to the operating room. Radiation exposure required for O-arm scans can be higher than that required for C-arm fluoroscopy, but it depends on fluoroscopy time. Inclusion of more medical centers and surgeons will better account for the variability of C-arm dose due to distinct patient characteristics, surgeon's preference, and individual institution's protocol. Level III-case-control study.
Bilateral movements increase sustained extensor force in the paretic arm.
Kang, Nyeonju; Cauraugh, James H
2018-04-01
Muscle weakness in the extensors poststroke is a common motor impairment. Unfortunately, research is unclear on whether bilateral movements increase extensor force production in the paretic arm. This study investigated sustained force production while stroke individuals maximally extended their wrist and fingers on their paretic arm. Specifically, we determined isometric force production in three conditions: (a) unilateral paretic arm, (b) unilateral nonparetic arm, and (c) bilateral (both arms executing the same movement simultaneously). Seventeen chronic stroke patients produced isometric sustained force by executing wrist and fingers extension in unilateral and bilateral contraction conditions. Mean force, force variability (coefficient of variation), and signal-to-noise ratio were calculated for each contraction condition. Analysis of two-way (Arm × Type of Condition: 2 × 2; Paretic or Nonparetic Arm × Unilateral or Bilateral Conditions) within-subjects ANOVAs revealed that the bilateral condition increased sustained force in the paretic arm, but reduced sustained force in the nonparetic arm. Further, although the paretic arm exhibited more force variability and less signal-to-noise ratio than the nonparetic arm during a unilateral condition, there were no differences when participants simultaneously executed isometric contractions with both arms. Our unique findings indicate that bilateral contractions transiently increased extensor force in the paretic arm. Implications for Rehabilitation Bilateral movements increased isometric wrsit extensor force in paretic arms and redcued force in nonparetic arms versus unilateral movements. Both paretic and nonparetic arms produced similar force variability and signal-to-noise ratio during bilateral movements. Increased sustained force in the paretic arm during the bilateral condition indicates that rehabilitation protocols based on bilateral movements may be beneficial for functional recovery.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baba, Junichi; Saitoh, Takayuki R.; Wada, Keiichi, E-mail: babajn@geo.titech.ac.jp
In order to understand the physical mechanisms underlying non-steady stellar spiral arms in disk galaxies, we analyzed the growing and damping phases of their spiral arms using three-dimensional N-body simulations. We confirmed that the spiral arms are formed due to a swing amplification mechanism that reinforces density enhancement as a seeded wake. In the damping phase, the Coriolis force exerted on a portion of the arm surpasses the gravitational force that acts to shrink the portion. Consequently, the stars in the portion escape from the arm, and subsequently they form a new arm at a different location. The time-dependent naturemore » of the spiral arms originates in the continual repetition of this nonlinear phenomenon. Since a spiral arm does not rigidly rotate, but follows the galactic differential rotation, the stars in the arm rotate at almost the same rate as the arm. In other words, every single position in the arm can be regarded as the corotation point. Due to interaction with their host arms, the energy and angular momentum of the stars change, thereby causing radial migration of the stars. During this process, the kinetic energy of random motion (random energy) of the stars does not significantly increase, and the disk remains dynamically cold. Owing to this low degree of disk heating, short-lived spiral arms can recurrently develop over many rotational periods. The resultant structure of the spiral arms in the N-body simulations is consistent with the observational nature of spiral galaxies. We conclude that the formation and structure of spiral arms in isolated disk galaxies can be reasonably understood by nonlinear interactions between a spiral arm and its constituent stars.« less
Kinematics of preferred and non-preferred handballing in Australian football.
Parrington, Lucy; Ball, Kevin; MacMahon, Clare
2015-01-01
In Australian football (AF), handballing proficiently with both the preferred and non-preferred arm is important at elite levels; yet, little information is available for handballing on the non-preferred arm. This study compared preferred and non-preferred arm handballing techniques. Optotrak Certus (100 Hz) collected three-dimensional data for 19 elite AF players performing handballs with the preferred and non-preferred arms. Position data, range of motion (ROM), and linear and angular velocities were collected and compared between preferred and non-preferred arms using dependent t-tests. The preferred arm exhibited significantly greater forearm and humerus ROM and angular velocity and significantly greater shoulder angular velocity at ball contact compared to the non-preferred arm. In addition, the preferred arm produced a significantly greater range of lateral bend and maximum lower-trunk speed, maximum strike-side hip speed and hand speed at ball contact than the non-preferred arm. The non-preferred arm exhibited a significantly greater shoulder angle and lower- and upper-trunk orientation angle, but significantly lower support-elbow angle, trunk ROM, and trunk rotation velocity compared to the preferred arm. Reduced ROM and angular velocities found in non-preferred arm handballs indicates a reduction in the degrees of freedom and a less developed skill. Findings have implication for development of handballing on the non-preferred arm.
Segmental Blood Flow and Hemodynamic State of Lymphedematous and Nonlymphedematous Arms
Montgomery, Leslie D.; Dietrich, Mary S.; Armer, Jane M.; Stewart, B. R.
2011-01-01
Abstract Background Findings regarding the influence hemodynamic factors, such as increased arterial blood flow or venous abnormalities, on breast cancer treatment-related lymphedema are mixed. The purpose of this study was to compare segmental arterial blood flow, venous blood return, and blood volumes between breast cancer survivors with treatment-related lymphedema and healthy normal individuals without lymphedema. Methods and Results A Tetrapolar High Resolution Impedance Monitor and Cardiotachometer were used to compare segmental arterial blood flow, venous blood return, and blood volumes between breast cancer survivors with treatment-related lymphedema and healthy normal volunteers. Average arterial blood flow in lymphedema-affected arms was higher than that in arms of healthy normal volunteers or in contralateral nonlymphedema affected arms. Time of venous outflow period of blood flow pulse was lower in lymphedema-affected arms than in healthy normal or lymphedema nonaffected arms. Amplitude of the venous component of blood flow pulse signal was lower in lymphedema-affected arms than in healthy or lymphedema nonaffected arms. Index of venular tone was also lower in lymphedema-affected arms than healthy or lymphedema nonaffected arms. Conclusions Both arterial and venous components may be altered in the lymphedema-affected arms when compared to healthy normal arms and contralateral arms in the breast cancer survivors. PMID:21417765
Role of arm motion in feet-in-place balance recovery.
Cheng, Kuangyou B; Wang, Kuan-Mao; Kuo, Shih-Yu
2015-09-18
Although considerable arm movements have been observed at loss of balance, research on standing balance focused primarily on the ankle and hip strategies. This study aimed to investigate the effect of arm motion on feet-in-place balance recovery. Participants stood on a single force plate and leaned forward with a straight body posture. They were then released from three forward-lean angles and regained balance without moving their forefeet under arm-swing (AS) and arm-constrained (AC) conditions. Higher success rates and shorter recovery times were found with arm motion under moderate balance perturbations. Recovery time was significantly correlated with peak linear momentum of the arms. Circumduction arm motion caused initial shoulder extension (backward arm movement) to generate reaction forces to pull the body forward, but later forward linear momentum of the arms helped move the whole body backward to avoid forward falling. However, greater lean angles increased difficulty in balance recovery, making the influences of the arms less significant. Since arm motions were observed in all participants with significantly enhanced performance under moderate balance perturbation, it was concluded that moving the arms should also be considered (together with the ankles and hips) as an effective strategy for balance recovery. Copyright © 2015 Elsevier Ltd. All rights reserved.
LeMoyne, Robert; Mastroianni, Timothy
2016-08-01
Natural gait consists of synchronous and rhythmic patterns for both the lower and upper limb. People with hemiplegia can experience reduced arm swing, which can negatively impact the quality of gait. Wearable and wireless sensors, such as through a smartphone, have demonstrated the ability to quantify various features of gait. With a software application the smartphone (iPhone) can function as a wireless gyroscope platform capable of conveying a gyroscope signal recording as an email attachment by wireless connectivity to the Internet. The gyroscope signal recordings of the affected hemiplegic arm with reduced arm swing arm and the unaffected arm are post-processed into a feature set for machine learning. Using a multilayer perceptron neural network a considerable degree of classification accuracy is attained to distinguish between the affected hemiplegic arm with reduced arm swing arm and the unaffected arm.
Control of a Serpentine Robot for Inspection Tasks
NASA Technical Reports Server (NTRS)
Colbaugh, R.; Glass, K.; Seraji, H.
1994-01-01
This paper presents a simple and robust kinematic control scheme for the JPL serpentine robot system. The proposed strategy is developed using the dampened-least-squares/configuration control methodology, and permits the considerable dexterity of the JPL serpentine robot to be effectively utilized for maneuvering in the congested and uncertain workspaces often encountered in inspection tasks. Computer simulation results are given for the 20 degree-of-freedom (DOF) manipulator system obtained by mounting the twelve DOF serpentine robot at the end-effector of an eight DOF Robotics Research arm/lathe-bed system. These simulations demonstrate that the proposed approach provides an effective method of controlling this complex system.
Structural insights into the inactivation of CRISPR-Cas systems by diverse anti-CRISPR proteins.
Zhu, Yuwei; Zhang, Fan; Huang, Zhiwei
2018-03-19
A molecular arms race is progressively being unveiled between prokaryotes and viruses. Prokaryotes utilize CRISPR-mediated adaptive immune systems to kill the invading phages and mobile genetic elements, and in turn, the viruses evolve diverse anti-CRISPR proteins to fight back. The structures of several anti-CRISPR proteins have now been reported, and here we discuss their structural features, with a particular emphasis on topology, to discover their similarities and differences. We summarize the CRISPR-Cas inhibition mechanisms of these anti-CRISPR proteins in their structural context. Considering anti-CRISPRs in this way will provide important clues for studying their origin and evolution.
Human-like Compliance for Dexterous Robot Hands
NASA Technical Reports Server (NTRS)
Jau, Bruno M.
1995-01-01
This paper describes the Active Electromechanical Compliance (AEC) system that was developed for the Jau-JPL anthropomorphic robot. The AEC system imitates the functionality of the human muscle's secondary function, which is to control the joint's stiffness: AEC is implemented through servo controlling the joint drive train's stiffness. The control strategy, controlling compliant joints in teleoperation, is described. It enables automatic hybrid position and force control through utilizing sensory feedback from joint and compliance sensors. This compliant control strategy is adaptable for autonomous robot control as well. Active compliance enables dual arm manipulations, human-like soft grasping by the robot hand, and opens the way to many new robotics applications.
Airborne RF Measurement System (ARMS) and Analysis of Representative Flight RF Environment
NASA Technical Reports Server (NTRS)
Koppen, Sandra V.; Ely, Jay J.; Smith, Laura J.; Jones, Richard A.; Fleck, Vincent J.; Salud, Maria Theresa; Mielnik, John J.
2007-01-01
Environmental radio frequency (RF) data over a broad band of frequencies (30 MHz to 1000 MHz) were obtained to evaluate the electromagnetic environment in airspace around several airports. An RF signal measurement system was designed utilizing a spectrum analyzer connected to the NASA Lancair Columbia 300 aircraft's VHF/UHF navigation antenna. This paper presents an overview of the RF measurement system and provides analysis of sample RF signal measurement data. This aircraft installation package and measurement system can be quickly returned to service if needed by future projects requiring measurement of an RF signal environment or exploration of suspected interference situations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gaustad, KL; Turner, DD
2009-05-30
This report provides a short description of the Atmospheric Radiation Measurement (ARM) Climate Research Facility (ACRF) microwave radiometer (MWR) RETrievel (MWRRET) value-added product (VAP) algorithm. This algorithm utilizes a complementary physical retrieval method and applies brightness temperature offsets to reduce spurious liquid water path (LWP) bias in clear skies resulting in significantly improved precipitable water vapor (PWV) and LWP retrievals. We present a general overview of the technique, input parameters, output products, and describe data quality checks. A more complete discussion of the theory and results is given in Turner et al. (2007b).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gaustad, KL; Turner, DD; McFarlane, SA
2011-07-25
This report provides a short description of the Atmospheric Radiation Measurement (ARM) Climate Research Facility microwave radiometer (MWR) Retrieval (MWRRET) value-added product (VAP) algorithm. This algorithm utilizes a complementary physical retrieval method and applies brightness temperature offsets to reduce spurious liquid water path (LWP) bias in clear skies resulting in significantly improved precipitable water vapor (PWV) and LWP retrievals. We present a general overview of the technique, input parameters, output products, and describe data quality checks. A more complete discussion of the theory and results is given in Turner et al. (2007b).
Programmed cell death as a defence against infection
Jorgensen, Ine; Rayamajhi, Manira; Miao, Edward A.
2017-01-01
Eukaryotic cells can die from physical trauma, resulting in necrosis. Alternately, they can die via programmed cell death upon stimulation of specific signalling pathways. Here we discuss the utility of four cell death pathways in innate immune defence against bacterial and viral infection: apoptosis, necroptosis, pyroptosis and NETosis. We describe the interactions that interweave different programmed cell death pathways, which create complex signalling networks that cross-guard each other in the evolutionary arms race with pathogens. Finally, we describe how the resulting cell corpses — apoptotic bodies, pore-induced intracellular traps (PITs) and neutrophil extracellular traps (NETs) — promote clearance of infection. PMID:28138137
Planet-driven Spiral Arms in Protoplanetary Disks. I. Formation Mechanism
NASA Astrophysics Data System (ADS)
Bae, Jaehan; Zhu, Zhaohuan
2018-06-01
Protoplanetary disk simulations show that a single planet can excite more than one spiral arm, possibly explaining the recent observations of multiple spiral arms in some systems. In this paper, we explain the mechanism by which a planet excites multiple spiral arms in a protoplanetary disk. Contrary to previous speculations, the formation of both primary and additional arms can be understood as a linear process when the planet mass is sufficiently small. A planet resonantly interacts with epicyclic oscillations in the disk, launching spiral wave modes around the Lindblad resonances. When a set of wave modes is in phase, they can constructively interfere with each other and create a spiral arm. More than one spiral arm can form because such constructive interference can occur for different sets of wave modes, with the exact number and launching position of the spiral arms being dependent on the planet mass as well as the disk temperature profile. Nonlinear effects become increasingly important as the planet mass increases, resulting in spiral arms with stronger shocks and thus larger pitch angles. This is found to be common for both primary and additional arms. When a planet has a sufficiently large mass (≳3 thermal masses for (h/r) p = 0.1), only two spiral arms form interior to its orbit. The wave modes that would form a tertiary arm for smaller mass planets merge with the primary arm. Improvements in our understanding of the formation of spiral arms can provide crucial insights into the origin of observed spiral arms in protoplanetary disks.
Tazoe, Toshiki; Nakajima, Tsuyoshi; Futatsubashi, Genki; Ohtsuka, Hiroyuki; Suzuki, Shinya; Zehr, E. Paul; Komiyama, Tomoyoshi
2016-01-01
Neural interactions between regulatory systems for rhythmic arm and leg movements are an intriguing issue in locomotor neuroscience. Amplitudes of early latency cutaneous reflexes (ELCRs) in stationary arm muscles are modulated during rhythmic leg or arm cycling but not during limb positioning or voluntary contraction. This suggests that interneurons mediating ELCRs to arm muscles integrate outputs from neural systems controlling rhythmic limb movements. Alternatively, outputs could be integrated at the motoneuron and/or supraspinal levels. We examined whether a separate effect on the ELCR pathways and cortico-motoneuronal excitability during arm and leg cycling is integrated by neural elements common to the lumbo-sacral and cervical spinal cord. The subjects performed bilateral leg cycling (LEG), contralateral arm cycling (ARM), and simultaneous contralateral arm and bilateral leg cycling (A&L), while ELCRs in the wrist flexor and shoulder flexor muscles were evoked by superficial radial (SR) nerve stimulation. ELCR amplitudes were facilitated by cycling tasks and were larger during A&L than during ARM and LEG. A low stimulus intensity during ARM or LEG generated a larger ELCR during A&L than the sum of ELCRs during ARM and LEG. We confirmed this nonlinear increase in single motor unit firing probability following SR nerve stimulation during A&L. Furthermore, motor-evoked potentials following transcranial magnetic and electrical stimulation did not show nonlinear potentiation during A&L. These findings suggest the existence of a common neural element of the ELCR reflex pathway that is active only during rhythmic arm and leg movement and receives convergent input from contralateral arms and legs. PMID:26961103
NASA Astrophysics Data System (ADS)
Hart, Ross E.; Bamford, Steven P.; Hayes, Wayne B.; Cardamone, Carolin N.; Keel, William C.; Kruk, Sandor J.; Lintott, Chris J.; Masters, Karen L.; Simmons, Brooke D.; Smethurst, Rebecca J.
2017-12-01
In this paper, we study the morphological properties of spiral galaxies, including measurements of spiral arm number and pitch angle. Using Galaxy Zoo 2, a stellar mass-complete sample of 6222 SDSS spiral galaxies is selected. We use the machine vision algorithm SPARCFIRE to identify spiral arm features and measure their associated geometries. A support vector machine classifier is employed to identify reliable spiral features, with which we are able to estimate pitch angles for half of our sample. We use these machine measurements to calibrate visual estimates of arm tightness, and hence estimate pitch angles for our entire sample. The properties of spiral arms are compared with respect to various galaxy properties. The star formation properties of galaxies vary significantly with arm number, but not pitch angle. We find that galaxies hosting strong bars have spiral arms substantially (4°-6°) looser than unbarred galaxies. Accounting for this, spiral arms associated with many-armed structures are looser (by 2°) than those in two-armed galaxies. In contrast to this average trend, galaxies with greater bulge-to-total stellar mass ratios display both fewer and looser spiral arms. This effect is primarily driven by the galaxy disc, such that galaxies with more massive discs contain more spiral arms with tighter pitch angles. This implies that galaxy central mass concentration is not the dominant cause of pitch angle and arm number variations between galaxies, which in turn suggests that not all spiral arms are governed by classical density waves or modal theories.
Code of Federal Regulations, 2014 CFR
2014-07-01
... if I do not have an arm's-length transportation contract or arm's-length tariff? 1206.111 Section... I do not have an arm's-length transportation contract or arm's-length tariff? (a) This section applies if you or your affiliate do not have an arm's-length transportation contract, including situations...
Code of Federal Regulations, 2012 CFR
2012-07-01
... if I do not have an arm's-length transportation contract or arm's-length tariff? 1206.111 Section... I do not have an arm's-length transportation contract or arm's-length tariff? (a) This section applies if you or your affiliate do not have an arm's-length transportation contract, including situations...
Code of Federal Regulations, 2013 CFR
2013-07-01
... if I do not have an arm's-length transportation contract or arm's-length tariff? 1206.111 Section... I do not have an arm's-length transportation contract or arm's-length tariff? (a) This section applies if you or your affiliate do not have an arm's-length transportation contract, including situations...
Code of Federal Regulations, 2011 CFR
2011-07-01
... if I do not have an arm's-length transportation contract or arm's-length tariff? 1206.111 Section... transportation allowance if I do not have an arm's-length transportation contract or arm's-length tariff? (a) This section applies if you or your affiliate do not have an arm's-length transportation contract...
Accounting for correlation in network meta-analysis with multi-arm trials.
Franchini, A J; Dias, S; Ades, A E; Jansen, J P; Welton, N J
2012-06-01
Multi-arm trials (trials with more than two arms) are particularly valuable forms of evidence for network meta-analysis (NMA). Trial results are available either as arm-level summaries, where effect measures are reported for each arm, or as contrast-level summaries, where the differences in effect between arms compare with the control arm chosen for the trial. We show that likelihood-based inference in both contrast-level and arm-level formats is identical if there are only two-arm trials, but that if there are multi-arm trials, results from the contrast-level format will be incorrect unless correlations are accounted for in the likelihood. We review Bayesian and frequentist software for NMA with multi-arm trials that can account for this correlation and give an illustrative example of the difference in estimates that can be introduced if the correlations are not incorporated. We discuss methods of imputing correlations when they cannot be derived from the reported results and urge trialists to report the standard error for the control arm even if only contrast-level summaries are reported. Copyright © 2012 John Wiley & Sons, Ltd. Copyright © 2012 John Wiley & Sons, Ltd.
Naidoo, Kogieleum; Grobler, Anneke C; Deghaye, Nicola; Reddy, Tarylee; Gengiah, Santhanalakshmi; Gray, Andrew; Karim, Salim Abdool
2015-01-01
Objective Initiation of antiretroviral therapy (ART) during tuberculosis (TB) treatment improves survival in TB-HIV co-infected patients. In patients with CD4+ counts <50cells/mm3, there is a substantial clinical and survival benefit of early ART initiation. The purpose of this study was to assess the costs and cost effectiveness of starting ART at various time points during TB treatment in patients with CD4+ counts ≥50cells/mm3. Methods In the SAPiT trial, 642 HIV-TB co-infected patients were randomized to three arms, either receiving ART within 4 weeks of starting TB treatment (early treatment arm; Arm-1), after the intensive phase of TB treatment (late treatment arm; Arm-2), or after completing TB treatment (sequential arm; Arm-3). Direct healthcare costs were measured from a provider perspective using a micro-costing approach. The incremental cost per death averted was calculated using the trial outcomes. Results For patients with CD4+ count≥50cells/mm3, median monthly variable costs per patient were $116, $113 and $102 in Arms-1, -2 and -3, respectively. There were 12 deaths in 177 patients in Arm-1, 8 deaths in 180 patients in the Arm-2 and 19 deaths in 172 patients in Arm-3. While the costs were lower in Arm-3, it had a substantially higher mortality rate. The incremental cost per death averted associated with moving from Arm-3 to Arm-2 was $4199. There was no difference in mortality between Arm-1 and Arm-2, but Arm-1 was slightly more expensive. Conclusions Initiation of ART after the completion of the intensive phase of TB treatment is cost effective for patients with CD4+ counts≥50cells/mm3. PMID:26167618
Thürer, Benjamin; Stein, Thorsten
2017-01-01
Intermanual transfer (motor memory generalization across arms) and motor memory interference (impairment of retest performance in consecutive motor learning) are well-investigated motor learning phenomena. However, the interplay of these phenomena remains elusive, i.e., whether intermanual interference occurs when two unimanual tasks are consecutively learned using different arms. Here, we examine intermanual interference when subjects consecutively adapt their right and left arm movements to novel dynamics. We considered two force field tasks A and B which were of the same structure but mirrored orientation (B = -A). The first test group (ABA-group) consecutively learned task A using their right arm and task B using their left arm before being retested for task A with their right arm. Another test group (AAA-group) learned only task A in the same right-left-right arm schedule. Control subjects learned task A using their right arm without intermediate left arm learning. All groups were able to adapt their right arm movements to force field A and both test groups showed significant intermanual transfer of this initial learning to the contralateral left arm of 21.9% (ABA-group) and 27.6% (AAA-group). Consecutively, both test groups adapted their left arm movements to force field B (ABA-group) or force field A (AAA-group). For the ABA-group, left arm learning caused significant intermanual interference of the initially learned right arm task (68.3% performance decrease). The performance decrease of the AAA-group (10.2%) did not differ from controls (15.5%). These findings suggest that motor control and learning of right and left arm movements involve partly similar neural networks or underlie a vital interhemispheric connectivity. Moreover, our results suggest a preferred internal task representation in extrinsic Cartesian-based coordinates rather than in intrinsic joint-based coordinates because interference was absent when learning was performed in extrinsically equivalent fashion (AAA-group) but interference occurred when learning was performed in intrinsically equivalent fashion (ABA-group). PMID:28459833
Stockinger, Christian; Thürer, Benjamin; Stein, Thorsten
2017-01-01
Intermanual transfer (motor memory generalization across arms) and motor memory interference (impairment of retest performance in consecutive motor learning) are well-investigated motor learning phenomena. However, the interplay of these phenomena remains elusive, i.e., whether intermanual interference occurs when two unimanual tasks are consecutively learned using different arms. Here, we examine intermanual interference when subjects consecutively adapt their right and left arm movements to novel dynamics. We considered two force field tasks A and B which were of the same structure but mirrored orientation (B = -A). The first test group (ABA-group) consecutively learned task A using their right arm and task B using their left arm before being retested for task A with their right arm. Another test group (AAA-group) learned only task A in the same right-left-right arm schedule. Control subjects learned task A using their right arm without intermediate left arm learning. All groups were able to adapt their right arm movements to force field A and both test groups showed significant intermanual transfer of this initial learning to the contralateral left arm of 21.9% (ABA-group) and 27.6% (AAA-group). Consecutively, both test groups adapted their left arm movements to force field B (ABA-group) or force field A (AAA-group). For the ABA-group, left arm learning caused significant intermanual interference of the initially learned right arm task (68.3% performance decrease). The performance decrease of the AAA-group (10.2%) did not differ from controls (15.5%). These findings suggest that motor control and learning of right and left arm movements involve partly similar neural networks or underlie a vital interhemispheric connectivity. Moreover, our results suggest a preferred internal task representation in extrinsic Cartesian-based coordinates rather than in intrinsic joint-based coordinates because interference was absent when learning was performed in extrinsically equivalent fashion (AAA-group) but interference occurred when learning was performed in intrinsically equivalent fashion (ABA-group).
C-arm rotation encoding with accelerometers.
Grzeda, Victor; Fichtinger, Gabor
2010-07-01
Fluoroscopic C-arms are being incorporated in computer-assisted interventions in increasing number. For these applications to work, the relative poses of imaging must be known. To find the pose, tracking methods such as optical cameras, electromagnetic trackers, and radiographic fiducials have been used-all hampered by significant shortcomings. We propose to recover the rotational pose of the C-arm using the angle-sensing ability of accelerometers, by exploiting the capability of the accelerometer to measure tilt angles. By affixing the accelerometer to a C-arm, the accelerometer tracks the C-arm pose during rotations of the C-arm. To demonstrate this concept, a C-arm analogue was constructed with a webcam device affixed to the C-arm model to mimic X-ray imaging. Then, measuring the offset between the accelerometer angle readings to the webcam pose angle, an angle correction equation (ACE) was created to properly tracking the C-arm rotational pose. Several tests were performed on the webcam C-arm model using the ACEs to tracking the primary and secondary angle rotations of the model. We evaluated the capability of linear and polynomial ACEs to tracking the webcam C-arm pose angle for different rotational scenarios. The test results showed that the accelerometer could track the pose of the webcam C-arm model with an accuracy of less than 1.0 degree. The accelerometer was successful in sensing the C-arm's rotation with clinically adequate accuracy in the C-arm webcam model.
How does a planet excite multiple spiral arms?
NASA Astrophysics Data System (ADS)
Bae, Jaehan; Zhu, Zhaohuan
2018-01-01
Protoplanetary disk simulations show that a single planet excites multiple spiral arms in the background disk, potentially supported by the multi-armed spirals revealed with recent high-resolution observations in some disks. The existence of multiple spiral arms is of importance in many aspects. It is empirically found that the arm-to-arm separation increases as a function of the planetary mass, so one can use the morphology of observed spiral arms to infer the mass of unseen planets. In addition, a spiral arm opens a radial gap as it steepens into a shock, so when a planet excites multiple spiral arms it can open multiple gaps in the disk. Despite the important implications, however, the formation mechanism of multiple spiral arms has not been fully understood by far.In this talk, we explain how a planet excites multiple spiral arms. The gravitational potential of a planet can be decomposed into a Fourier series, a sum of individual azimuthal modes having different azimuthal wavenumbers. Using a linear wave theory, we first demonstrate that appropriate sets of Fourier decomposed waves can be in phase, raising a possibility that constructive interference among the waves can produce coherent structures - spiral arms. More than one spiral arm can form since such constructive interference can occur at different positions in the disk for different sets of waves. We then verify this hypothesis using a suite of two-dimensional hydrodynamic simulations. Finally, we present non-linear behavior in the formation of multiple spiral arms.
Arm Activity During Daily Life in Individuals With Chronic Obstructive Pulmonary Disease.
Janaudis-Ferreira, Tania; Mathur, Sunita; Romano, Julia Marie; Goldstein, Roger Samuel; Brooks, Dina
2016-01-01
To determine whether individuals with chronic obstructive pulmonary disease (COPD) have decreased arm activity during daily life compared with healthy controls and explore the relationships between arm activity during daily life and arm functional measures in individuals with COPD. This was a prospective cross-sectional study that included 30 people with COPD and 14 healthy controls. Subjects attended a single assessment session in which measurements of arm exercise capacity, arm functional performance, self-perception of performance during activities of daily living (ADL), shoulder and elbow flexion force and biceps and triceps thickness were performed. On completion of this session, participants were issued a wrist actigraph and asked to wear the device on the dominant arm for 24 hours for 7 consecutive days. Compared with healthy controls, patients with COPD presented decreased total activity level in daily life (P = .001). When corrected for walking, the level of arm activity did not differ between individuals with COPD and healthy controls (P = .62). No correlations were found between arm activity and arm exercise capacity, arm functional performance, upper limb muscle strength, and self-perception of performance during ADL (r =-0.20 to 0.14; all P ≥ .10). Arm activity intensity in individuals with COPD did not differ from that of healthy controls when measured by a wrist actigraph. Moreover, arm activity was not associated with other clinical outcomes of arm function. Disability during ADL is multifactorial, and only limited inferences of function can be made from accelerometer data.
Ma, Guilei; Zhang, Chao; Zhang, Linhua; Sun, Hongfan; Song, Cunxian; Wang, Chun; Kong, Deling
2016-01-01
Star-shaped block copolymers based on poly(D,L-lactide-co-glycolide) (PLGA) and poly(ethylene glycol) (PEG) (st-PLGA-PEG) were synthesized with structural variation on arm numbers in order to investigate the relationship between the arm numbers of st-PLGA-PEG copolymers and their micelle properties. st-PLGA-PEG copolymers with arm numbers 3, 4 and 6 were synthesized by using different cores such as trimethylolpropane, pentaerythritol and dipentaerythritol, and were characterized by nuclear magnetic resonance and gel permeation chromatography. The critical micelle concentration decreased with increasing arm numbers in st-PLGA-PEG copolymers. The doxorubicin-loaded st-PLGA-PEG micelles were prepared by a modified nanoprecipitation method. Micellar properties such as particle size, drug loading content and in vitro drug release behavior were investigated as a function of the number of arms and compared with each other. The doxorubicin-loaded 4-arm PLGA-PEG micelles were found to have the highest cellular uptake efficiency and cytotoxicity compared with 3-arm PLGA-PEG micelles and 6-arm PLGA-PEG micelles. The results suggest that structural tailoring of arm numbers from st-PLGA-PEG copolymers could provide a new strategy for designing drug carriers of high efficiency. Structural tailoring of arm numbers from star shaped-PLGA-PEG copolymers (3-arm/4-arm/6-arm-PLGA-PEG) could provide a new strategy for designing drug carriers of high efficiency.
Task automation in a successful industrial telerobot
NASA Technical Reports Server (NTRS)
Spelt, Philip F.; Jones, Sammy L.
1994-01-01
In this paper, we discuss cooperative work by Oak Ridge National Laboratory and Remotec, Inc., to automate components of the operator's workload using Remotec's Andros telerobot, thereby providing an enhanced user interface which can be retrofit to existing fielded units as well as being incorporated into new production units. Remotec's Andros robots are presently used by numerous electric utilities to perform tasks in reactors where substantial exposure to radiation exists, as well as by the armed forces and numerous law enforcement agencies. The automation of task components, as well as the video graphics display of the robot's position in the environment, will enhance all tasks performed by these users, as well as enabling performance in terrain where the robots cannot presently perform due to lack of knowledge about, for instance, the degree of tilt of the robot. Enhanced performance of a successful industrial mobile robot leads to increased safety and efficiency of performance in hazardous environments. The addition of these capabilities will greatly enhance the utility of the robot, as well as its marketability.
Kaufman, Howard L; Hunger, Matthias; Hennessy, Meliessa; Schlichting, Michael; Bharmal, Murtuza
2018-02-01
To assess the association between tumor response and health-related quality of life (HRQoL) in patients with metastatic Merkel cell carcinoma treated with the anti-PD-L1 avelumab. Phase II single-arm trial (NCT02155647) data of 88 patients were analyzed. Correlations between percentage reduction in tumor size and change from baseline in Functional Assessment of Cancer Therapy - General (FACT-G), FACT - Melanoma (FACT-M) and EuroQol-5 Dimension scores were calculated. HRQoL and utility by tumor response (per the Response Evaluation Criteria In Solid Tumors version 1.1) was estimated. Tumor shrinkage correlated positively with patients' change from baseline in the FACT-M total (0.364 [95% CI: 0.050-0.607]) and subscale scores. Differences in HRQoL and utility between nonprogressive disease and progressive disease were clinically relevant. In patients with metastatic Merkel cell carcinoma, nonprogression during treatment with avelumab correlated with gains in HRQoL.
Nitric oxide nanoparticles: pre-clinical utility as a therapeutic for intramuscular abscesses.
Schairer, David; Martinez, Luis R; Blecher, Karin; Chouake, Jason; Nacharaju, Parimala; Gialanella, Philip; Friedman, Joel M; Nosanchuk, Joshua D; Friedman, Adam
2012-01-01
Nitric oxide (NO) is a critical component of host defense against invading pathogens; however, its therapeutic utility is limited due to a lack of practical delivery systems. Recently, a NO-releasing nanoparticulate platform (NO-np) was shown to have in vitro broad-spectrum antimicrobial activity and in vivo pre-clinical efficacy in a dermal abscess model. To extend these findings, both topical (TP) and intralesional (IL) NO-np administration was evaluated in a MRSA intramuscular murine abscess model and compared with vancomycin. All treatment arms accelerated abscess clearance clinically, histologically, and by microbiological assays on both days 4 and 7 following infection. However, abscesses treated with NO-np via either route demonstrated a more substantial, statistically significant decrease in bacterial survival based on colony forming unit assays and histologically revealed less inflammatory cell infiltration and preserved muscular architecture. These data suggest that the NO-np may be an effective addition to our armament for deep soft tissue infections.
Economic analysis of routine neuromonitoring of recurrent laryngeal nerve in total thyroidectomy.
Sanabria, Álvaro; Ramírez, Adonis
2015-01-01
Thyroidectomy is a common surgery. Routine searching of the recurrent laryngeal nerve is the most important strategy to avoid palsy. Neuromonitoring has been recommended to decrease recurrent laryngeal nerve palsy. To assess if neuromonitoring of recurrent laryngeal nerve during thyroidectomy is cost-effective in a developing country. We designed a decision analysis to assess the cost-effectiveness of recurrent laryngeal nerve neuromonitoring. For probabilities, we used data from a meta-analysis. Utility was measured using preference values. We considered direct costs. We conducted a deterministic and a probabilistic analysis. We did not find differences in utility between arms. The frequency of recurrent laryngeal nerve injury was 1% in the neuromonitor group and 1.6% for the standard group. Thyroidectomy without monitoring was the less expensive alternative. The incremental cost-effectiveness ratio was COP$ 9,112,065. Routine neuromonitoring in total thyroidectomy with low risk of recurrent laryngeal nerve injury is neither cost-useful nor cost-effective in the Colombian health system.
Robotic end gripper with a band member to engage object
Pollard, R.E.; Robinson, S.C.; Thompson, W.F.; Couture, S.A.; Sutton, B.J.
1994-05-10
An end effector for use with robotic arms and like devices is described that utilizes a flexible band to draw an object against an anvil having a concave surface. One typical convex surface is created by a V-block, with an apex of the V being centrally located. If an object to be grasped is fragile, the contour of the concave surface closely matches the surface of the object. Typically the movement of the band is effected by a linear actuator, with the anvil remaining fixed relative to a support base. Several embodiments are described that utilize variations in drawing the band toward the anvil, with one of these embodiments described in detail in the form of a fabricated unit. One embodiment includes a cover element that can be moved over an object after the grasping thereof, with this cover potentially serving various functions. Movement of the cover can be effected with a second linear actuator. 8 figures.
High precision redundant robotic manipulator
Young, Kar-Keung David
1998-01-01
A high precision redundant robotic manipulator for overcoming contents imposed by obstacles or imposed by a highly congested work space. One embodiment of the manipulator has four degrees of freedom and another embodiment has seven degreed of freedom. Each of the embodiments utilize a first selective compliant assembly robot arm (SCARA) configuration to provide high stiffness in the vertical plane, a second SCARA configuration to provide high stiffness in the horizontal plane. The seven degree of freedom embodiment also utilizes kinematic redundancy to provide the capability of avoiding obstacles that lie between the base of the manipulator and the end effector or link of the manipulator. These additional three degrees of freedom are added at the wrist link of the manipulator to provide pitch, yaw and roll. The seven degrees of freedom embodiment uses one revolute point per degree of freedom. For each of the revolute joints, a harmonic gear coupled to an electric motor is introduced, and together with properly designed based servo controllers provide an end point repeatability of less than 10 microns.
NASA Astrophysics Data System (ADS)
Laurent, Claes; Jonsson, Bjorn; Vegfors, Magnus; Eneling, Martin; Lindberg, Lars-Goran
2004-07-01
A soft (silicone) probe, containing six light emitting diodes (880 nm) and three photo detectors, utilizes photoplethysmography (PPG) to monitor pulsations from the brachialis artery under an occluding cuff during deflation. When the arterial pulse returns, measured by PPG, the corresponding pressure in the cuff is determined. This pressure is assumed to equal the systolic pressure. An assessment trial was performed on 21 patients (9 women and 12 men, aged 27-69) at the Neuro-Intensive care unit. Since the patients were already provided with arterial needles, invasive blood pressure could be used as the reference. By choosing a threshold, for detecting pulses, as a fraction (4%) of the maximum amplitude, the systolic blood pressure was underestimated (-0.57 mmHg, SD 12.1). The range of systolic pressure for the patients was 95.5 - 199.0 mmHg, n=14. The method is promising, but improvements still have to be made in order to improve the technique.