Sample records for utility arm system

  1. Design criteria for the light duty utility arm system end effectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pardini, A.F.; Kiebel, G.R.

    1995-12-01

    The purpose of this document is to provide criteria for the design of end effectors that will be used as part of the Light Duty Utility Arm (LDUA) System. Actual component design, fabrication, testing, and inspection will be performed by various DOE laboratories, industry, and academia. This document augments WHC-SD-TD-FRD-003, `Functions and Requirements for the Light Duty Utility Arm Integrated System` (F). All requirements dictated in the F shall also be applicable in this document. Whenever conflicts arise between this document and the F, this document shall take precedence.

  2. The Effect of Armed Conflict on the Utilization of Maternal Health Services in Uganda: A Population-based Study.

    PubMed

    Namasivayam, Amrita; Arcos González, Pedro; Castro Delgado, Rafael; Chi, Primus Che

    2017-10-03

    Maternal mortality rates can be adversely affected by armed conflict, implying a greater level of vulnerability among women, and is often linked to the lack of or limited access to maternal healthcare during conflict. Previous research in Uganda has shown that armed conflict negatively impacts women's utilization of maternal healthcare services for a multitude of reasons at the individual, health-system and political levels. This study compared aggregated Demographic and Health Surveys data from 13 districts in Northern Uganda, a conflict-affected region, with data from the rest of the country, for the use of maternal healthcare services for the years 1988, 1995, 2000, 2006 and 2011, using statistical analyses and logistic regression. Specific indicators for maternal healthcare utilization included contraceptive use, antenatal care, skilled assistance at birth and institutional delivery. Use of contraception and institutional deliveries among women in Northern Uganda was significantly lower compared to the rest of the country. However, skilled assistance at birth among women in Northern Uganda was significantly higher. The findings in this study show that armed conflict can have a negative impact on aspects of maternal healthcare such as contraceptive use and institutional deliveries; however, other indicators such as skilled assistance at birth were seen to be better among conflict-affected populations. This reiterates the complex nature of armed conflict and the interplay of different factors such as conflict intensity, existing health systems and services, and humanitarian interventions that could influence maternal healthcare utilization. Armed conflict, maternal health utilization, Northern Uganda, contraception, skilled assistance at birth, antenatal care, institutional delivery.

  3. Accurate positioning of long, flexible ARM's (Articulated Robotic Manipulator)

    NASA Technical Reports Server (NTRS)

    Malachowski, Michael J.

    1988-01-01

    An articulated robotic manipulator (ARM) system is being designed for space applications. Work being done on a concept utilizing an infinitely stiff laser beam for position reference is summarized. The laser beam is projected along the segments of the ARM, and the position is sensed by the beam rider modules (BRM) mounted on the distal ends of the segments. The BRM concept is the heart of the system. It utilizes a combination of lateral displacements and rotational and distance measurement sensors. These determine the relative position of the two ends of the segments with respect to each other in six degrees of freedom. The BRM measurement devices contain microprocessor controlled data acquisition and active positioning components. An indirect adaptive controller is used to accurately control the position of the ARM.

  4. Kinematically redundant arm formulations for coordinated multiple arm implementations

    NASA Technical Reports Server (NTRS)

    Bailey, Robert W.; Quiocho, Leslie J.; Cleghorn, Timothy F.

    1990-01-01

    Although control laws for kinematically redundant robotic arms were presented as early as 1969, redundant arms have only recently become recognized as viable solutions to limitations inherent to kinematically sufficient arms. The advantages of run-time control optimization and arm reconfiguration are becoming increasingly attractive as the complexity and criticality of robotic systems continues to progress. A generalized control law for a spatial arm with 7 or more degrees of freedom (DOF) based on Whitney's resolved rate formulation is given. Results from a simulation implementation utilizing this control law are presented. Furthermore, results from a two arm simulation are presented to demonstrate the coordinated control of multiple arms using this formulation.

  5. Thresholds for conservation and management: structured decision making as a conceptual framework

    USGS Publications Warehouse

    Nichols, James D.; Eaton, Mitchell J.; Martin, Julien; Edited by Guntenspergen, Glenn R.

    2014-01-01

    changes in system dynamics. They are frequently incorporated into ecological models used to project system responses to management actions. Utility thresholds are components of management objectives and are values of state or performance variables at which small changes yield substantial changes in the value of the management outcome. Decision thresholds are values of system state variables at which small changes prompt changes in management actions in order to reach specified management objectives. Decision thresholds are derived from the other components of the decision process.We advocate a structured decision making (SDM) approach within which the following components are identified: objectives (possibly including utility thresholds), potential actions, models (possibly including ecological thresholds), monitoring program, and a solution algorithm (which produces decision thresholds). Adaptive resource management (ARM) is described as a special case of SDM developed for recurrent decision problems that are characterized by uncertainty. We believe that SDM, in general, and ARM, in particular, provide good approaches to conservation and management. Use of SDM and ARM also clarifies the distinct roles of ecological thresholds, utility thresholds, and decision thresholds in informed decision processes.

  6. Control strategies for a telerobot

    NASA Technical Reports Server (NTRS)

    Ohara, John; Stasi, Bill

    1989-01-01

    One of the major issues impacting the utility of telerobotic systems for space is the development of effective control strategies. For near-term applications, telerobot control is likely to utilize teleoperation methodologies with integrated supervisory control capabilities to assist the operator. Two different approaches to telerobotic control are evaluated: bilateral force reflecting master controllers and proportional rate six degrees-of-freedom hand controllers. The controllers' performance of single manipulator arm tasks is compared. Simultaneous operation of both manipulator arms and complex multiaxis slave arm movements is investigated. Task times are significantly longer and fewer errors are committed with the hand controllers. The hand controllers are also rated significantly higher in cognitive and manual control workload on the two-arm task. The master controllers are rated significantly higher in physical workload. The implications of these findings for space teleoperations and higher levels of control are discussed.

  7. Systems and methods for coating conduit interior surfaces utilizing a thermal spray gun with extension arm

    DOEpatents

    Moore, Karen A.; Zatorski, Raymond A.

    2005-07-12

    Systems and methods for applying a coating to an interior surface of a conduit. In one embodiment, a spray gun configured to apply a coating is attached to an extension arm which may be inserted into the bore of a pipe. The spray gun may be a thermal spray gun adapted to apply a powder coating. An evacuation system may be used to provide a volume area of reduced air pressure for drawing overspray out of the pipe interior during coating. The extension arm as well as the spray gun may be cooled to maintain a consistent temperature in the system, allowing for more consistent coating.

  8. STS-61 crew utilizing Virtual Reality in training for HST repair mission

    NASA Technical Reports Server (NTRS)

    1993-01-01

    Astronaut Jeffrey A. Hoffman, one of four crewmembers for STS-61 that will conduct scheduled spacewalks during the flight, wears a special helmet and gloves designed to assist in proper positioning near the telescope while on the end of the robot arm. Crewmembers are utilizing a new virtual reality training aid which assists in refining positioning patterns for Space Shuttle Endeavour's Remote Manipulator System (RMS) (36890); Astronaut Claude Nicollier looks at a computer display of the Shuttle's robot arm movements as Thomas D. Akers and Kathryn C. Thornton, mission specialists look on. Nicollier will be responsible for maneuvering the astronauts while they stand in a foot restraint on the end of the RMS arm (36891,36894); Hoffman wears a special helmet and gloves designed to assist in proper positioning near the telescope while on the end of the robot arm (35892); Nicollier looks at a computer display of the Shuttle's robot arm movements as Akers looks on (36893); While (l-r) Astron

  9. C-arm positioning using virtual fluoroscopy for image-guided surgery

    NASA Astrophysics Data System (ADS)

    de Silva, T.; Punnoose, J.; Uneri, A.; Goerres, J.; Jacobson, M.; Ketcha, M. D.; Manbachi, A.; Vogt, S.; Kleinszig, G.; Khanna, A. J.; Wolinsky, J.-P.; Osgood, G.; Siewerdsen, J. H.

    2017-03-01

    Introduction: Fluoroscopically guided procedures often involve repeated acquisitions for C-arm positioning at the cost of radiation exposure and time in the operating room. A virtual fluoroscopy system is reported with the potential of reducing dose and time spent in C-arm positioning, utilizing three key advances: robust 3D-2D registration to a preoperative CT; real-time forward projection on GPU; and a motorized mobile C-arm with encoder feedback on C-arm orientation. Method: Geometric calibration of the C-arm was performed offline in two rotational directions (orbit α, orbit β). Patient registration was performed using image-based 3D-2D registration with an initially acquired radiograph of the patient. This approach for patient registration eliminated the requirement for external tracking devices inside the operating room, allowing virtual fluoroscopy using commonly available systems in fluoroscopically guided procedures within standard surgical workflow. Geometric accuracy was evaluated in terms of projection distance error (PDE) in anatomical fiducials. A pilot study was conducted to evaluate the utility of virtual fluoroscopy to aid C-arm positioning in image guided surgery, assessing potential improvements in time, dose, and agreement between the virtual and desired view. Results: The overall geometric accuracy of DRRs in comparison to the actual radiographs at various C-arm positions was PDE (mean ± std) = 1.6 ± 1.1 mm. The conventional approach required on average 8.0 ± 4.5 radiographs spent "fluoro hunting" to obtain the desired view. Positioning accuracy improved from 2.6o ± 2.3o (in α) and 4.1o ± 5.1o (in β) in the conventional approach to 1.5o ± 1.3o and 1.8o ± 1.7o, respectively, with the virtual fluoroscopy approach. Conclusion: Virtual fluoroscopy could improve accuracy of C-arm positioning and save time and radiation dose in the operating room. Such a system could be valuable to training of fluoroscopy technicians as well as intraoperative use in fluoroscopically guided procedures.

  10. RM-10A robotic manipulator system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, J.R.; Coughlan, J.B.; Harvey, H.W.

    1988-01-01

    The REMOTE RM-10A is a man-replacement manipulator system that has been developed specifically for use in radioactive and other hazardous environments. It can be teleoperated, with man-in-the-loop, for unstructured tasks or programmed to perform routine tasks automatically much like robots in the automated manufacturing industry. The RM-10A is a servomanipulator utilizing a closed-loop, microprocessor-based control system. The system consists of a slave assembly, master control station, and interconnecting cabling. The slave assembly is the part of the system that enters the hostile environment. It is man-like is size and configuration with two identical arms attached to a torso structure. Eachmore » arm attaches to the torso using two captive screws and two guide pins. The guide pins position and stabilize an arm during removal and reinstallation and also align the two electrical connectors located in the arm support plate and torso. These features allow easy remote replacement of an arm, and commonality of the arms allow interchangeability. The water-resistant slave assembly is equipped with gaskets and O-ring seals in the torso and arm and camera assemblies. In addition, each slave arm's elbow, wrist, and tong are protected by replaceable polyurethane boots. An upper camera assembly, consisting of a color television (TV) camera, 6:1 zoom lens, and a pan/tilt unit, mount to the torso to provide remote viewing capability.« less

  11. Methods for coating conduit interior surfaces utilizing a thermal spray gun with extension arm

    DOEpatents

    Moore, Karen A.; Zatorski, Raymond A.

    2007-10-02

    Systems and methods for applying a coating to an interior surface of a conduit. In one embodiment, a spray gun configured to apply a coating is attached to an extension arm which may be inserted into the bore of a pipe. The spray gun may be a thermal spray gun adapted to apply a powder coating. An evacuation system may be used to provide a volume area of reduced air pressure for drawing overspray out of the pipe interior during coating. The extension arm as well as the spray gun may be cooled to maintain a consistent temperature in the system, allowing for more consistent coating.

  12. Ethnic and Environmental Influences on Vitamin D Requirement in Military Personnel

    DTIC Science & Technology

    2006-10-01

    25(OH)D, Ca2+ and PTH at baseline. We used a portable colorimeter that utilizes the CIE L*a*b* color system to measure constitutive skin color of...at baseline. We used a portable colorimeter that utilizes the CIE L*a*b* color system to measure constitutive skin tone of the upper inner arm. The

  13. Single-camera visual odometry to track a surgical X-ray C-arm base.

    PubMed

    Esfandiari, Hooman; Lichti, Derek; Anglin, Carolyn

    2017-12-01

    This study provides a framework for a single-camera odometry system for localizing a surgical C-arm base. An application-specific monocular visual odometry system (a downward-looking consumer-grade camera rigidly attached to the C-arm base) is proposed in this research. The cumulative dead-reckoning estimation of the base is extracted based on frame-to-frame homography estimation. Optical-flow results are utilized to feed the odometry. Online positional and orientation parameters are then reported. Positional accuracy of better than 2% (of the total traveled distance) for most of the cases and 4% for all the cases studied and angular accuracy of better than 2% (of absolute cumulative changes in orientation) were achieved with this method. This study provides a robust and accurate tracking framework that not only can be integrated with the current C-arm joint-tracking system (i.e. TC-arm) but also is capable of being employed for similar applications in other fields (e.g. robotics).

  14. A robot arm simulation with a shared memory multiprocessor machine

    NASA Technical Reports Server (NTRS)

    Kim, Sung-Soo; Chuang, Li-Ping

    1989-01-01

    A parallel processing scheme for a single chain robot arm is presented for high speed computation on a shared memory multiprocessor. A recursive formulation that is derived from a virtual work form of the d'Alembert equations of motion is utilized for robot arm dynamics. A joint drive system that consists of a motor rotor and gears is included in the arm dynamics model, in order to take into account gyroscopic effects due to the spinning of the rotor. The fine grain parallelism of mechanical and control subsystem models is exploited, based on independent computation associated with bodies, joint drive systems, and controllers. Efficiency and effectiveness of the parallel scheme are demonstrated through simulations of a telerobotic manipulator arm. Two different mechanical subsystem models, i.e., with and without gyroscopic effects, are compared, to show the trade-off between efficiency and accuracy.

  15. New generation intraoperative three-dimensional imaging (O-arm) in 100 spine surgeries: does it change the surgical procedure?

    PubMed

    Sembrano, Jonathan N; Santos, Edward Rainier G; Polly, David W

    2014-02-01

    The O-arm (Medtronic Sofamor Danek, Inc., Memphis, TN, USA), an intraoperative CT scan imaging system, may provide high-quality imaging information to the surgeon. To our knowledge, its impact on spine surgery has not been studied. We reviewed 100 consecutive spine surgical procedures which utilized the new generation mobile intraoperative CT imaging system (O-arm). The most common diagnoses were degenerative conditions (disk disease, spondylolisthesis, stenosis and acquired kyphosis), seen in 49 patients. The most common indication for imaging was spinal instrumentation in 81 patients (74 utilized pedicle screws). In 52 (70%) of these, the O-arm was used to assess screw position after placement; in 22 (30%), it was coupled with Stealth navigation (Medtronic Sofamor Danek, Inc.) to guide screw placement. Another indication was to assess adequacy of spinal decompression in 38 patients; in 19 (50%) of these, intrathecal contrast material was used to obtain an intraoperative CT myelogram. In 20 patients O-arm findings led to direct surgeon intervention in the form of screw removal/repositioning (n=13), further decompression (n=6), interbody spacer repositioning (n=1), and removal of kyphoplasty trocar (n=1). In 20% of spine surgeries, the procedure was changed based on O-arm imaging findings. We found the O-arm to be useful for assessment of instrumentation position, adequacy of spinal decompression, and confirmation of balloon containment and cement filling in kyphoplasty. When used with navigation for image-guided surgery, it obviated the need for registration. Published by Elsevier Ltd.

  16. Robotic Mirror Therapy System for Functional Recovery of Hemiplegic Arms.

    PubMed

    Beom, Jaewon; Koh, Sukgyu; Nam, Hyung Seok; Kim, Wonshik; Kim, Yoonjae; Seo, Han Gil; Oh, Byung-Mo; Chung, Sun Gun; Kim, Sungwan

    2016-08-15

    Mirror therapy has been performed as effective occupational therapy in a clinical setting for functional recovery of a hemiplegic arm after stroke. It is conducted by eliciting an illusion through use of a mirror as if the hemiplegic arm is moving in real-time while moving the healthy arm. It can facilitate brain neuroplasticity through activation of the sensorimotor cortex. However, conventional mirror therapy has a critical limitation in that the hemiplegic arm is not actually moving. Thus, we developed a real-time 2-axis mirror robot system as a simple add-on module for conventional mirror therapy using a closed feedback mechanism, which enables real-time movement of the hemiplegic arm. We used 3 Attitude and Heading Reference System sensors, 2 brushless DC motors for elbow and wrist joints, and exoskeletal frames. In a feasibility study on 6 healthy subjects, robotic mirror therapy was safe and feasible. We further selected tasks useful for activities of daily living training through feedback from rehabilitation doctors. A chronic stroke patient showed improvement in the Fugl-Meyer assessment scale and elbow flexor spasticity after a 2-week application of the mirror robot system. Robotic mirror therapy may enhance proprioceptive input to the sensory cortex, which is considered to be important in neuroplasticity and functional recovery of hemiplegic arms. The mirror robot system presented herein can be easily developed and utilized effectively to advance occupational therapy.

  17. Earth orbital teleoperator manipulator system evaluation program

    NASA Technical Reports Server (NTRS)

    Brye, R. G.; Frederick, P. N.; Kirkpatrick, M., III; Shields, N. L., Jr.

    1977-01-01

    The operator's ability to perform five manipulator tip movements while using monoptic and stereoptic video systems was assessed. Test data obtained were compared with previous results to determine the impact of camera placement and stereoptic viewing on manipulator system performance. The tests were performed using the NASA MSFC extendible stiff arm Manipulator and an analog joystick controller. Two basic manipulator tasks were utilized. The minimum position change test required the operator to move the manipulator arm to touch a target contract. The dexterity test required removal and replacement of pegs.

  18. Operations and maintenance manual for the LDUA supervisory control and data acquisition system (LDUA System 4200) and control network (LDUA System 4400)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barnes, G.A.

    1998-03-11

    This document defines the requirements applicable to the operation, maintenance and storage of the Supervisory Control and Data Acquisition System (SCADAS) and Control Network in support of the Light Duty Utility Arm (LDUA) operations.

  19. Bridge permeameter

    DOEpatents

    Graf, Darin C.; Warpinski, Norman R.

    1996-01-01

    A system for single-phase, steady-state permeability measurements of porous rock utilizes a fluid bridge arrangement analogous to a Wheatstone bridge. The arms of the bridge contain the sample and calibrated flow resistors.

  20. Utilizing Microelectromechanical Systems (MEMS) Micro-Shutter Designs for Adaptive Coded Aperture Imaging (ACAI) Technologies

    DTIC Science & Technology

    2009-03-01

    52 Figure 4-1: Applied voltage versus deflection curve for Poly1/Poly2 stacked 300-μm single hot-arm actuator (shown on right...58 Figure 4-2: Applied voltage versus deflection curve for Poly1/Poly2 stacked 300-μm double hot-arm actuator (shown on...61 Figure 4-5: Deflection vs. power curves for an individual wedge from

  1. A synchronized computational architecture for generalized bilateral control of robot arms

    NASA Technical Reports Server (NTRS)

    Bejczy, Antal K.; Szakaly, Zoltan

    1987-01-01

    This paper describes a computational architecture for an interconnected high speed distributed computing system for generalized bilateral control of robot arms. The key method of the architecture is the use of fully synchronized, interrupt driven software. Since an objective of the development is to utilize the processing resources efficiently, the synchronization is done in the hardware level to reduce system software overhead. The architecture also achieves a balaced load on the communication channel. The paper also describes some architectural relations to trading or sharing manual and automatic control.

  2. Bridge permeameter

    DOEpatents

    Graf, D.C.; Warpinski, N.R.

    1996-08-13

    A system is described for single-phase, steady-state permeability measurements of porous rock which utilizes a fluid bridge arrangement analogous to a Wheatstone bridge. The arms of the bridge contain the sample and calibrated flow resistors. 8 figs.

  3. Bridge permeameter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Graf, D.C.; Warpinski, N.R.

    A system is described for single-phase, steady-state permeability measurements of porous rock which utilizes a fluid bridge arrangement analogous to a Wheatstone bridge. The arms of the bridge contain the sample and calibrated flow resistors. 8 figs.

  4. Tactile Robotic Topographical Mapping Without Force or Contact Sensors

    NASA Technical Reports Server (NTRS)

    Burke, Kevin; Melko, Joseph; Krajewski, Joel; Cady, Ian

    2008-01-01

    A method of topographical mapping of a local solid surface within the range of motion of a robot arm is based on detection of contact between the surface and the end effector (the fixture or tool at the tip of the robot arm). The method was conceived to enable mapping of local terrain by an exploratory robot on a remote planet, without need to incorporate delicate contact switches, force sensors, a vision system, or other additional, costly hardware. The method could also be used on Earth for determining the size and shape of an unknown surface in the vicinity of a robot, perhaps in an unanticipated situation in which other means of mapping (e.g., stereoscopic imaging or laser scanning with triangulation) are not available. The method uses control software modified to utilize the inherent capability of the robotic control system to measure the joint positions, the rates of change of the joint positions, and the electrical current demanded by the robotic arm joint actuators. The system utilizes these coordinate data and the known robot-arm kinematics to compute the position and velocity of the end effector, move the end effector along a specified trajectory, place the end effector at a specified location, and measure the electrical currents in the joint actuators. Since the joint actuator current is approximately proportional to the actuator forces and torques, a sudden rise in joint current, combined with a slowing of the joint, is a possible indication of actuator stall and surface contact. Hence, even though the robotic arm is not equipped with contact sensors, it is possible to sense contact (albeit with reduced sensitivity) as the end effector becomes stalled against a surface that one seeks to measure.

  5. Filtering sensory information with XCSF: improving learning robustness and robot arm control performance.

    PubMed

    Kneissler, Jan; Stalph, Patrick O; Drugowitsch, Jan; Butz, Martin V

    2014-01-01

    It has been shown previously that the control of a robot arm can be efficiently learned using the XCSF learning classifier system, which is a nonlinear regression system based on evolutionary computation. So far, however, the predictive knowledge about how actual motor activity changes the state of the arm system has not been exploited. In this paper, we utilize the forward velocity kinematics knowledge of XCSF to alleviate the negative effect of noisy sensors for successful learning and control. We incorporate Kalman filtering for estimating successive arm positions, iteratively combining sensory readings with XCSF-based predictions of hand position changes over time. The filtered arm position is used to improve both trajectory planning and further learning of the forward velocity kinematics. We test the approach on a simulated kinematic robot arm model. The results show that the combination can improve learning and control performance significantly. However, it also shows that variance estimates of XCSF prediction may be underestimated, in which case self-delusional spiraling effects can hinder effective learning. Thus, we introduce a heuristic parameter, which can be motivated by theory, and which limits the influence of XCSF's predictions on its own further learning input. As a result, we obtain drastic improvements in noise tolerance, allowing the system to cope with more than 10 times higher noise levels.

  6. Direct interaction with an assistive robot for individuals with chronic stroke.

    PubMed

    Kmetz, Brandon; Markham, Heather; Brewer, Bambi R

    2011-01-01

    Many robotic systems have been developed to provide assistance to individuals with disabilities. Most of these systems require the individual to interact with the robot via a joystick or keypad, though some utilize techniques such as speech recognition or selection of objects with a laser pointer. In this paper, we describe a prototype system using a novel method of interaction with an assistive robot. A touch-sensitive skin enables the user to directly guide a robotic arm to a desired position. When the skin is released, the robot remains fixed in position. The target population for this system is individuals with hemiparesis due to chronic stroke. The system can be used as a substitute for the paretic arm and hand in bimanual tasks such as holding a jar while removing the lid. This paper describes the hardware and software of the prototype system, which includes a robotic arm, the touch-sensitive skin, a hook-style prehensor, and weight compensation and speech recognition software.

  7. Decoupling Identification for Serial Two-Link Two-Inertia System

    NASA Astrophysics Data System (ADS)

    Oaki, Junji; Adachi, Shuichi

    The purpose of our study is to develop a precise model by applying the technique of system identification for the model-based control of a nonlinear robot arm, under taking joint-elasticity into consideration. We previously proposed a systematic identification method, called “decoupling identification,” for a “SCARA-type” planar two-link robot arm with elastic joints caused by the Harmonic-drive® reduction gears. The proposed method serves as an extension of the conventional rigid-joint-model-based identification. The robot arm is treated as a serial two-link two-inertia system with nonlinearity. The decoupling identification method using link-accelerometer signals enables the serial two-link two-inertia system to be divided into two linear one-link two-inertia systems. The MATLAB®'s commands for state-space model estimation are utilized in the proposed method. Physical parameters such as motor inertias, link inertias, joint-friction coefficients, and joint-spring coefficients are estimated through the identified one-link two-inertia systems using a gray-box approach. This paper describes accuracy evaluations using the two-link arm for the decoupling identification method under introducing closed-loop-controlled elements and varying amplitude-setup of identification-input. Experimental results show that the identification method also works with closed-loop-controlled elements. Therefore, the identification method is applicable to a “PUMA-type” vertical robot arm under gravity.

  8. Utility of optical facial feature and arm movement tracking systems to enable text communication in critically ill patients who cannot otherwise communicate.

    PubMed

    Muthuswamy, M B; Thomas, B N; Williams, D; Dingley, J

    2014-09-01

    Patients recovering from critical illness especially those with critical illness related neuropathy, myopathy, or burns to face, arms and hands are often unable to communicate by writing, speech (due to tracheostomy) or lip reading. This may frustrate both patient and staff. Two low cost movement tracking systems based around a laptop webcam and a laser/optical gaming system sensor were utilised as control inputs for on-screen text creation software and both were evaluated as communication tools in volunteers. Two methods were used to control an on-screen cursor to create short sentences via an on-screen keyboard: (i) webcam-based facial feature tracking, (ii) arm movement tracking by laser/camera gaming sensor and modified software. 16 volunteers with simulated tracheostomy and bandaged arms to simulate communication via gross movements of a burned limb, communicated 3 standard messages using each system (total 48 per system) in random sequence. Ten and 13 minor typographical errors occurred with each system respectively, however all messages were comprehensible. Speed of sentence formation ranged from 58 to 120s with the facial feature tracking system, and 60-160s with the arm movement tracking system. The average speed of sentence formation was 81s (range 58-120) and 104s (range 60-160) for facial feature and arm tracking systems respectively, (P<0.001, 2-tailed independent sample t-test). Both devices may be potentially useful communication aids in patients in general and burns critical care units who cannot communicate by conventional means, due to the nature of their injuries. Copyright © 2014 Elsevier Ltd and ISBI. All rights reserved.

  9. Cost-utility analysis of the EVOLVO study on remote monitoring for heart failure patients with implantable defibrillators: randomized controlled trial.

    PubMed

    Zanaboni, Paolo; Landolina, Maurizio; Marzegalli, Maurizio; Lunati, Maurizio; Perego, Giovanni B; Guenzati, Giuseppe; Curnis, Antonio; Valsecchi, Sergio; Borghetti, Francesca; Borghi, Gabriella; Masella, Cristina

    2013-05-30

    Heart failure patients with implantable defibrillators place a significant burden on health care systems. Remote monitoring allows assessment of device function and heart failure parameters, and may represent a safe, effective, and cost-saving method compared to conventional in-office follow-up. We hypothesized that remote device monitoring represents a cost-effective approach. This paper summarizes the economic evaluation of the Evolution of Management Strategies of Heart Failure Patients With Implantable Defibrillators (EVOLVO) study, a multicenter clinical trial aimed at measuring the benefits of remote monitoring for heart failure patients with implantable defibrillators. Two hundred patients implanted with a wireless transmission-enabled implantable defibrillator were randomized to receive either remote monitoring or the conventional method of in-person evaluations. Patients were followed for 16 months with a protocol of scheduled in-office and remote follow-ups. The economic evaluation of the intervention was conducted from the perspectives of the health care system and the patient. A cost-utility analysis was performed to measure whether the intervention was cost-effective in terms of cost per quality-adjusted life year (QALY) gained. Overall, remote monitoring did not show significant annual cost savings for the health care system (€1962.78 versus €2130.01; P=.80). There was a significant reduction of the annual cost for the patients in the remote arm in comparison to the standard arm (€291.36 versus €381.34; P=.01). Cost-utility analysis was performed for 180 patients for whom QALYs were available. The patients in the remote arm gained 0.065 QALYs more than those in the standard arm over 16 months, with a cost savings of €888.10 per patient. Results from the cost-utility analysis of the EVOLVO study show that remote monitoring is a cost-effective and dominant solution. Remote management of heart failure patients with implantable defibrillators appears to be cost-effective compared to the conventional method of in-person evaluations. ClinicalTrials.gov NCT00873899; http://clinicaltrials.gov/show/NCT00873899 (Archived by WebCite at http://www.webcitation.org/6H0BOA29f).

  10. STS-61 crew utilizing Virtual Reality in training for HST repair mission

    NASA Image and Video Library

    1993-06-11

    Astronaut Jeffrey A. Hoffman, one of four crewmembers for STS-61 that will conduct scheduled spacewalks during the flight, wears a special helmet and gloves designed to assist in proper positioning near the telescope while on the end of the robot arm. Crewmembers are utilizing a new virtual reality training aid which assists in refining positioning patterns for Space Shuttle Endeavour's Remote Manipulator System (RMS) (36890); Astronaut Claude Nicollier looks at a computer display of the Shuttle's robot arm movements as Thomas D. Akers and Kathryn C. Thornton, mission specialists look on. Nicollier will be responsible for maneuvering the astronauts while they stand in a foot restraint on the end of the RMS arm (36891,36894); Hoffman wears a special helmet and gloves designed to assist in proper positioning near the telescope while on the end of the robot arm (35892); Nicollier looks at a computer display of the Shuttle's robot arm movements as Akers looks on (36893); While (l-r) Astronauts Kenneth Bowersox, Kathryn Thornton, Richard O. Covey and Thomas D. Akers watch, Nicollier moves the Robot arm to desired locations in the Shuttle's payload bay using the Virtual Reality program (36895); Bowersox takes his turn maneuvering the RMS while mission specialist Hoffman, wearing the Virtual Reality helmet, follows his own progress on the end of the robot arm. Crewmembers participating during the training session are (l-r) Astronauts Akers, Hoffman, Bowersox, Nicollier, Covey, and Thornton. In the background, David Homan, an engineer in the JSC Engineering Directorate's Automation and Robotics Division, looks on (36896).

  11. Towards a real-time interface between a biomimetic model of sensorimotor cortex and a robotic arm

    PubMed Central

    Dura-Bernal, Salvador; Chadderdon, George L; Neymotin, Samuel A; Francis, Joseph T; Lytton, William W

    2015-01-01

    Brain-machine interfaces can greatly improve the performance of prosthetics. Utilizing biomimetic neuronal modeling in brain machine interfaces (BMI) offers the possibility of providing naturalistic motor-control algorithms for control of a robotic limb. This will allow finer control of a robot, while also giving us new tools to better understand the brain’s use of electrical signals. However, the biomimetic approach presents challenges in integrating technologies across multiple hardware and software platforms, so that the different components can communicate in real-time. We present the first steps in an ongoing effort to integrate a biomimetic spiking neuronal model of motor learning with a robotic arm. The biomimetic model (BMM) was used to drive a simple kinematic two-joint virtual arm in a motor task requiring trial-and-error convergence on a single target. We utilized the output of this model in real time to drive mirroring motion of a Barrett Technology WAM robotic arm through a user datagram protocol (UDP) interface. The robotic arm sent back information on its joint positions, which was then used by a visualization tool on the remote computer to display a realistic 3D virtual model of the moving robotic arm in real time. This work paves the way towards a full closed-loop biomimetic brain-effector system that can be incorporated in a neural decoder for prosthetic control, to be used as a platform for developing biomimetic learning algorithms for controlling real-time devices. PMID:26709323

  12. An approach to simultaneous control of trajectory and interaction forces in dual-arm configurations

    NASA Technical Reports Server (NTRS)

    Yun, Xiaoping; Kumar, Vijay R.

    1991-01-01

    An approach to the control of constrained dynamic systems such as multiple arm systems, multifingered grippers, and walking vehicles is described. The basic philosophy is to utilize a minimal set of inputs to control the trajectory and the surplus input to control the constraint or interaction forces and moments in the closed chain. A dynamic control model for the closed chain is derived that is suitable for designing a controller in which the trajectory and the interaction forces and moments are explicitly controlled. Nonlinear feedback techniques derived from differential geometry are then applied to linearize and decouple the nonlinear model. These ideas are illustrated through a planar example in which two arms are used for cooperative manipulation. Results from a simulation are used to illustrate the efficacy of the method.

  13. Photoelectric radar servo control system based on ARM+FPGA

    NASA Astrophysics Data System (ADS)

    Wu, Kaixuan; Zhang, Yue; Li, Yeqiu; Dai, Qin; Yao, Jun

    2016-01-01

    In order to get smaller, faster, and more responsive requirements of the photoelectric radar servo control system. We propose a set of core ARM + FPGA architecture servo controller. Parallel processing capability of FPGA to be used for the encoder feedback data, PWM carrier modulation, A, B code decoding processing and so on; Utilizing the advantage of imaging design in ARM Embedded systems achieves high-speed implementation of the PID algorithm. After the actual experiment, the closed-loop speed of response of the system cycles up to 2000 times/s, in the case of excellent precision turntable shaft, using a PID algorithm to achieve the servo position control with the accuracy of + -1 encoder input code. Firstly, This article carry on in-depth study of the embedded servo control system hardware to determine the ARM and FPGA chip as the main chip with systems based on a pre-measured target required to achieve performance requirements, this article based on ARM chip used Samsung S3C2440 chip of ARM7 architecture , the FPGA chip is chosen xilinx's XC3S400 . ARM and FPGA communicate by using SPI bus, the advantage of using SPI bus is saving a lot of pins for easy system upgrades required thereafter. The system gets the speed datas through the photoelectric-encoder that transports the datas to the FPGA, Then the system transmits the datas through the FPGA to ARM, transforms speed datas into the corresponding position and velocity data in a timely manner, prepares the corresponding PWM wave to control motor rotation by making comparison between the position data and the velocity data setted in advance . According to the system requirements to draw the schematics of the photoelectric radar servo control system and PCB board to produce specially. Secondly, using PID algorithm to control the servo system, the datas of speed obtained from photoelectric-encoder is calculated position data and speed data via high-speed digital PID algorithm and coordinate models. Finally, a large number of experiments verify the reliability of embedded servo control system's functions, the stability of the program and the stability of the hardware circuit. Meanwhile, the system can also achieve the satisfactory of user experience, to achieve a multi-mode motion, real-time motion status monitoring, online system parameter changes and other convenient features.

  14. Effect of a nurse-led psychoeducational intervention on healthcare service utilization among adults with advanced cancer

    PubMed Central

    Martinez, Kathryn A.; Friese, Christopher; Kershaw, Trace; Given, Charles W.; Fendrick, A. Mark; Northouse, Laurel

    2015-01-01

    Purpose/Objectives To examine differences in healthcare service utilization among patients with advanced cancer participating in a nurse-led psychoeducational intervention. Design Secondary analysis of trial data. Setting Four Michigan cancer centers. Sample 484 patients with advanced cancer. Methods Patients were randomized to three groups: brief intervention, extensive intervention, or control. Medical chart review took place at baseline, three months, and six months to measure patients’ healthcare service utilization, defined as emergency department (ED) visits or inpatient hospitalizations. Multivariable logistic regression was used to examine the odds, by study arm, of visiting the ED and being hospitalized, controlling for patient sociodemographic and health status factors, as well as baseline health-related quality of life (QOL). Main Research Variables Study arm (brief, extensive, or control), ED visitation (one or more times versus none), inpatient hospitalizations (one or more times versus none), and covariates. Findings No significant differences in ED visits or inpatient hospitalizations were observed among study arms. ED visits were more frequent for patients with lung or colorectal cancer, more comorbidities, and lower baseline QOL. Baseline QOL was associated with inpatient hospitalizations in the adjusted analysis. Conclusions The psychoeducational intervention, either in brief or extensive format, is unlikely to increase healthcare service utilization. Implications for Nursing Efficacious nurse-led psychoeducational interventions to improve QOL do not place undue burdens on the healthcare system and may improve care. PMID:26148327

  15. Mini Versus Standard Percutaneous Nephrolithotomy: The Impact of Sheath Size on Intrarenal Pelvic Pressure and Infectious Complications in a Porcine Model.

    PubMed

    Loftus, Christopher J; Hinck, Bryan; Makovey, Iryna; Sivalingam, Sri; Monga, Manoj

    2018-04-01

    To determine how sheath and endoscope size affect intrarenal pelvic pressures and risk of postoperative infectious complications comparing "Mini" vs "Standard" percutaneous nephrolithotomy (PCNL). Uropathogenic Escherichia coli were grown and 10 9 of them were instilled into the porcine renal pelvis through retrograde access for 1 hour. Percutaneous access utilized a 14/16F 20 cm ureteral access sheath for the Mini arm and a 30F sheath for the Standard arm. Nephroscopy was simulated utilizing either an 8/9.8F semirigid ureteroscope or 26F nephroscope for 1 hour while intrarenal pelvic pressure was continuously monitored. Blood and tissue cultures of kidney, liver, and spleen biopsies were plated and incubated and positive cultures were confirmed with polymerase chain reaction. Intrapelvic pressures were higher in the Mini group, 18.76 ± 5.82 mm Hg vs 13.56 ± 5.82 mm Hg (p < 0.0001). Time spent above 30 mm Hg was greater in the Mini arm, 117.0 seconds vs 66.1 seconds (p = 0.0452). All pigs had positive kidney tissue cultures whereas spleen cultures were positive in 100% and 60% of pigs in the Mini and Standard arms, respectively (p = 0.0253); 90% and 30% had positive liver tissue culture in the Mini and Standard arms, respectively (p = 0.0062). Blood cultures were positive in 30% of pigs in the Mini arm compared with none in the Standard arm (p = 0.0603). Mini-PCNL was associated with higher intrarenal pressures and higher risk of end organ bacterial seeding in the setting of an infected collecting system. This suggests a higher potential for infectious complications in a clinical setting.

  16. Utilization of Military Women. (A Report of Increased Utilization of Military Women, FY-1973-1977)

    DTIC Science & Technology

    The purpose of the study was to examine the utilization of military women and to prepare contingency plans for increasing the use of women to offset...to the utilization of military women : History of women in the Armed Forces; potential supply of women for the Armed Forces; assignment policies...attrition rates; costs of military women versus men; and service plans for increasing use of military women .

  17. Anthropomorphic Telemanipulation System in Terminus Control Mode

    NASA Technical Reports Server (NTRS)

    Jau, Bruno M.; Lewis, M. Anthony; Bejczy, Antal K.

    1994-01-01

    This paper describes a prototype anthropomorphic kinesthetic telepresence system that is being developed at JPL. It utilizes dexterous terminus devices in the form of an exoskeleton force-sensing master glove worn by the operator and a replica four finger anthropomorphic slave hand. The newly developed master glove is integrated with our previously developed non-anthropomorphic six degree of freedom (DOF) universal force-reflecting hand controller (FRHC). The mechanical hand and forearm are mounted to an industrial robot (PUMA 560), replacing its standard forearm. The notion of 'terminus control mode' refers to the fact that only the terminus devices (glove and robot hand) are of anthropomorphic nature, and the master and slave arms are non-anthropomorphic. The system is currently being evaluated, focusing on tool handling and astronaut equivalent task executions. The evaluation revealed the system's potential for tool handling but it also became evident that hand tool manipulations and space operations require a dual arm robot. This paper describes the system's principal components, its control and computing architecture, discusses findings of the tool handling evaluation, and explains why common tool handling and EVA space tasks require dual arm robots.

  18. Electrically Stimulated Antagonist Muscle Contraction Increased Muscle Mass and Bone Mineral Density of One Astronaut - Initial Verification on the International Space Station.

    PubMed

    Shiba, Naoto; Matsuse, Hiroo; Takano, Yoshio; Yoshimitsu, Kazuhiro; Omoto, Masayuki; Hashida, Ryuki; Tagawa, Yoshihiko; Inada, Tomohisa; Yamada, Shin; Ohshima, Hiroshi

    2015-01-01

    Musculoskeletal atrophy is one of the major problems of extended periods of exposure to weightlessness such as on the International Space Station (ISS). We developed the Hybrid Training System (HTS) to maintain an astronaut's musculoskeletal system using an electrically stimulated antagonist to resist the volitional contraction of the agonist instead of gravity. The present study assessed the system's orbital operation capability and utility, as well as its preventative effect on an astronaut's musculoskeletal atrophy. HTS was attached to the non-dominant arm of an astronaut staying on the ISS, and his dominant arm without HTS was established as the control (CTR). 10 sets of 10 reciprocal elbow curls were one training session, and 12 total sessions of training (3 times per week for 4 weeks) were performed. Pre and post flight ground based evaluations were performed by Biodex (muscle performance), MRI (muscle volume), and DXA (BMD, lean [muscle] mass, fat mass). Pre and post training inflight evaluations were performed by a hand held dynamometer (muscle force) and a measuring tape (upper arm circumference). The experiment was completed on schedule, and HTS functioned well without problems. Isokinetic elbow extension torque (Nm) changed -19.4% in HTS, and -21.7% in CTR. Isokinetic elbow flexion torque changed -23.7% in HTS, and there was no change in CTR. Total Work (Joule) of elbow extension changed -8.3% in HTS, and +0.3% in CTR. For elbow flexion it changed -23.3% in HTS and -32.6% in CTR. Average Power (Watts) of elbow extension changed +22.1% in HTS and -8.0% in CTR. For elbow flexion it changed -6.5% in HTS and -4.8% in CTR. Triceps muscle volume according to MRI changed +11.7% and that of biceps was +2.1% using HTS, however -0.1% and -0.4% respectively for CTR. BMD changed +4.6% in the HTS arm and -1.2% for CTR. Lean (muscle) mass of the arm changed only +10.6% in HTS. Fat mass changed -12.6% in HTS and -6.4% in CTR. These results showed the orbital operation capability and utility, and the preventive effect of HTS for an astronaut's musculoskeletal atrophy. The initial flight data together with the ground data obtained so far will be utilized in the future planning of human space exploration.

  19. Cost-Utility Analysis of the EVOLVO Study on Remote Monitoring for Heart Failure Patients With Implantable Defibrillators: Randomized Controlled Trial

    PubMed Central

    Landolina, Maurizio; Marzegalli, Maurizio; Lunati, Maurizio; Perego, Giovanni B; Guenzati, Giuseppe; Curnis, Antonio; Valsecchi, Sergio; Borghetti, Francesca; Borghi, Gabriella; Masella, Cristina

    2013-01-01

    Background Heart failure patients with implantable defibrillators place a significant burden on health care systems. Remote monitoring allows assessment of device function and heart failure parameters, and may represent a safe, effective, and cost-saving method compared to conventional in-office follow-up. Objective We hypothesized that remote device monitoring represents a cost-effective approach. This paper summarizes the economic evaluation of the Evolution of Management Strategies of Heart Failure Patients With Implantable Defibrillators (EVOLVO) study, a multicenter clinical trial aimed at measuring the benefits of remote monitoring for heart failure patients with implantable defibrillators. Methods Two hundred patients implanted with a wireless transmission–enabled implantable defibrillator were randomized to receive either remote monitoring or the conventional method of in-person evaluations. Patients were followed for 16 months with a protocol of scheduled in-office and remote follow-ups. The economic evaluation of the intervention was conducted from the perspectives of the health care system and the patient. A cost-utility analysis was performed to measure whether the intervention was cost-effective in terms of cost per quality-adjusted life year (QALY) gained. Results Overall, remote monitoring did not show significant annual cost savings for the health care system (€1962.78 versus €2130.01; P=.80). There was a significant reduction of the annual cost for the patients in the remote arm in comparison to the standard arm (€291.36 versus €381.34; P=.01). Cost-utility analysis was performed for 180 patients for whom QALYs were available. The patients in the remote arm gained 0.065 QALYs more than those in the standard arm over 16 months, with a cost savings of €888.10 per patient. Results from the cost-utility analysis of the EVOLVO study show that remote monitoring is a cost-effective and dominant solution. Conclusions Remote management of heart failure patients with implantable defibrillators appears to be cost-effective compared to the conventional method of in-person evaluations. Trial Registration ClinicalTrials.gov NCT00873899; http://clinicaltrials.gov/show/NCT00873899 (Archived by WebCite at http://www.webcitation.org/6H0BOA29f). PMID:23722666

  20. Tracker-on-C for cone-beam CT-guided surgery: evaluation of geometric accuracy and clinical applications

    NASA Astrophysics Data System (ADS)

    Reaungamornrat, S.; Otake, Y.; Uneri, A.; Schafer, S.; Mirota, D. J.; Nithiananthan, S.; Stayman, J. W.; Khanna, A. J.; Reh, D. D.; Gallia, G. L.; Taylor, R. H.; Siewerdsen, J. H.

    2012-02-01

    Conventional surgical tracking configurations carry a variety of limitations in line-of-sight, geometric accuracy, and mismatch with the surgeon's perspective (for video augmentation). With increasing utilization of mobile C-arms, particularly those allowing cone-beam CT (CBCT), there is opportunity to better integrate surgical trackers at bedside to address such limitations. This paper describes a tracker configuration in which the tracker is mounted directly on the Carm. To maintain registration within a dynamic coordinate system, a reference marker visible across the full C-arm rotation is implemented, and the "Tracker-on-C" configuration is shown to provide improved target registration error (TRE) over a conventional in-room setup - (0.9+/-0.4) mm vs (1.9+/-0.7) mm, respectively. The system also can generate digitally reconstructed radiographs (DRRs) from the perspective of a tracked tool ("x-ray flashlight"), the tracker, or the C-arm ("virtual fluoroscopy"), with geometric accuracy in virtual fluoroscopy of (0.4+/-0.2) mm. Using a video-based tracker, planning data and DRRs can be superimposed on the video scene from a natural perspective over the surgical field, with geometric accuracy (0.8+/-0.3) pixels for planning data overlay and (0.6+/-0.4) pixels for DRR overlay across all C-arm angles. The field-of-view of fluoroscopy or CBCT can also be overlaid on real-time video ("Virtual Field Light") to assist C-arm positioning. The fixed transformation between the x-ray image and tracker facilitated quick, accurate intraoperative registration. The workflow and precision associated with a variety of realistic surgical tasks were significantly improved using the Tracker-on-C - for example, nearly a factor of 2 reduction in time required for C-arm positioning, reduction or elimination of dose in "hunting" for a specific fluoroscopic view, and confident placement of the x-ray FOV on the surgical target. The proposed configuration streamlines the integration of C-arm CBCT with realtime tracking and demonstrated utility in a spectrum of image-guided interventions (e.g., spine surgery) benefiting from improved accuracy, enhanced visualization, and reduced radiation exposure.

  1. Visual Display of 5p-arm and 3p-arm miRNA Expression with a Mobile Application.

    PubMed

    Pan, Chao-Yu; Kuo, Wei-Ting; Chiu, Chien-Yuan; Lin, Wen-Chang

    2017-01-01

    MicroRNAs (miRNAs) play important roles in human cancers. In previous studies, we have demonstrated that both 5p-arm and 3p-arm of mature miRNAs could be expressed from the same precursor and we further interrogated the 5p-arm and 3p-arm miRNA expression with a comprehensive arm feature annotation list. To assist biologists to visualize the differential 5p-arm and 3p-arm miRNA expression patterns, we utilized a user-friendly mobile App to display. The Cancer Genome Atlas (TCGA) miRNA-Seq expression information. We have collected over 4,500 miRNA-Seq datasets from 15 TCGA cancer types and further processed them with the 5p-arm and 3p-arm annotation analysis pipeline. In order to be displayed with the RNA-Seq Viewer App, annotated 5p-arm and 3p-arm miRNA expression information and miRNA gene loci information were converted into SQLite tables. In this distinct application, for any given miRNA gene, 5p-arm miRNA is illustrated on the top of chromosome ideogram and 3p-arm miRNA is illustrated on the bottom of chromosome ideogram. Users can then easily interrogate the differentially 5p-arm/3p-arm expressed miRNAs with their mobile devices. This study demonstrates the feasibility and utility of RNA-Seq Viewer App in addition to mRNA-Seq data visualization.

  2. Predicting SF-6D utility scores from the Neck Disability Index and Numeric Rating Scales for Neck and Arm Pain

    PubMed Central

    Carreon, Leah Y.; Anderson, Paul A.; McDonough, Christine M.; Djurasovic, Mladen; Glassman, Steven D.

    2010-01-01

    Study Design Cross-sectional cohort Objective This study aims to provide an algorithm estimate SF-6D utilities using data from the NDI, neck pain and arm pain scores. Summary of Background Data Although cost-utility analysis is increasingly used to provide information about the relative value of alternative interventions, health state values or utilities are rarely available from clinical trial data. The Neck Disability Index (NDI) and numeric rating scales for neck and arm pain, are widely used disease-specific measures of symptoms, function and disability in patients with cervical degenerative disorders. The purpose of this study is to provide an algorithm to allow estimation of SF-6D utilities using data from the NDI, and numeric rating scales for neck and arm pain. Methods SF-36, NDI, neck and arm pain rating scale scores were prospectively collected pre-operatively, at 12 and 24 months post-operatively in 2080 patients undergoing cervical fusion for degenerative disorders. SF-6D utilities were computed and Spearman correlation coefficients were calculated for paired observations from multiple time points between NDI, neck and arm pain scores and SF-6D utility scores. SF-6D scores were estimated from the NDI, neck and arm pain scores using a linear regression model. Using a separate, independent dataset of 396 patients in which and NDI scores were available SF-6D was estimated for each subject and compared to their actual SF-6D. Results The mean age for those in the development sample, was 50.4 ± 11.0 years and 33% were male. In the validation sample the mean age was 53.1 ± 9.9 years and 35% were male. Correlations between the SF-6D and the NDI, neck and arm pain scores were statistically significant (p<0.0001) with correlation coefficients of 0.82, 0.62, and 0.50 respectively. The regression equation using NDI alone to predict SF-6D had an R2 of 0.66 and a root mean square error (RMSE) of 0.056. In the validation analysis, there was no statistically significant difference (p=0.961) between actual mean SF-6D (0.49 ± 0.08) and the estimated mean SF-6D score (0.49 ± 0.08) using the NDI regression model. Conclusion This regression-based algorithm may be a useful tool to predict SF-6D scores in studies of cervical degenerative disease that have collected NDI but not utility scores. PMID:20847713

  3. [Hand fine motor skills and use of both hand and arm in subjects after a stroke: a systematic review].

    PubMed

    Ostolaza, M; Abudarham, J; Dilascio, S; Drault-Boedo, E; Gallo, S; Garcete, A; Kramer, M; Maiaru, M; Mendelevich, A; Modica, M; Peralta, F; Sanchez-Correa, C

    2017-04-01

    In clinical practice it is important to be able to assess the function of the upper limb of the patient who has suffered a stroke. There is currently no systemic review that could identify assessment tools for the 'fine use of the hand' and 'use of both hand and arm'. Primary, to identify observational tools which can assess the fine use of the hand and the use of both hand and arm in patients with stroke sequels. Secondary, to analyze the bias risk in the included articles, describing and categorizing the clinical utility, validity and reliability. A search was carried in Medline, LILACS, SciELO and Open Grey, which included articles published until October 2015. Studies that validate assessing tools of the upper limb in subjects with a stroke sequel which evaluate the fine use of the hand and the use of both hand and arm were included. Eleven tools in evaluate observational haven been selected, which assess the fine use of the hand and the use of hand and arm. In every case both validity and reliability have been reported, but clinical utility has been less considered for assessment. The studies that researched these tools showed a high risk of bias in their development. ARAT-19 showed a lower bias risk, but when it has to do with applicability and the reference trial is taken into account, the level of concern is high.

  4. Health Instruction Packages: Venipuncture and Intravenous Therapy.

    ERIC Educational Resources Information Center

    Gray, P. Allen, Jr.; And Others

    Text, illustrations, and exercises are utilized in these five learning modules to instruct nursing students in techniques for initiating intravenous (I.V.) therapy. The first module, "Selection of a Venipuncture Site: Arm" by P. Allen Gray, Jr., describes the utilization of a tourniquet in locating filled veins in the arm. The second…

  5. Arm swing magnitude and asymmetry during gait in the early stages of Parkinson's disease.

    PubMed

    Lewek, Michael D; Poole, Roxanne; Johnson, Julia; Halawa, Omar; Huang, Xuemei

    2010-02-01

    The later stages of Parkinson's disease (PD) are characterized by altered gait patterns. Although decreased arm swing during gait is the most frequently reported motor dysfunction in individuals with PD, quantitative descriptions of gait in early PD have largely ignored upper extremity movements. This study was designed to perform a quantitative analysis of arm swing magnitude and asymmetry that might be useful in the assessment of early PD. Twelve individuals with early PD (in "off" state) and eight controls underwent gait analysis using an optically-based motion capture system. Participants were instructed to walk at normal and fast velocities, and then on heels (to minimize push-off). Arm swing was measured as the excursion of the wrist with respect to the pelvis. Arm swing magnitude for each arm, and inter-arm asymmetry, were compared between groups. Both groups had comparable gait velocities (p = 0.61), and there was no significant difference between the groups in the magnitude of arm swing in all walking conditions for the arm that swung more (p = 0.907) or less (p = 0.080). Strikingly, the PD group showed significantly greater arm swing asymmetry (asymmetry angle: 13.9 + or - 7.9%) compared to the control group (asymmetry angle: 5.1 + or - 4.0%; p = 0.003). Unlike arm swing magnitude, arm swing asymmetry unequivocally differs between people with early PD and controls. Such quantitative evaluation of arm swing, especially its asymmetry, may have utility for early and differential diagnosis, and for tracking disease progression in patients with later PD. Copyright 2009 Elsevier B.V. All rights reserved.

  6. Arm Swing Magnitude and Asymmetry During Gait in the Early Stages of Parkinson's Disease

    PubMed Central

    Lewek, Michael D.; Poole, Roxanne; Johnson, Julia; Halawa, Omar; Huang, Xuemei

    2009-01-01

    The later stages of Parkinson's disease (PD) are characterized by altered gait patterns. Although decreased arm swing during gait is the most frequently reported motor dysfunction in individuals with PD, quantitative descriptions of gait in early PD have largely ignored upper extremity movements. This study was designed to perform a quantitative analysis of arm swing magnitude and asymmetry that might be useful in the assessment of early PD. Twelve individuals with early PD (in “off” state) and eight controls underwent gait analysis using an optically-based motion capture system. Participants were instructed to walk at normal and fast velocities, and then on heels (to minimize push-off). Arm swing was measured as the excursion of the wrist with respect to the pelvis. Arm swing magnitude for each arm, and inter-arm asymmetry, were compared between groups. Both groups had comparable gait velocities (p=0.61), and there was no significant difference between the groups in the magnitude of arm swing in all walking conditions for the arm that swung more (p=0.907) or less (p=0.080). Strikingly, the PD group showed significantly greater arm swing asymmetry (asymmetry angle: 13.9±7.9%) compared to the control group (asymmetry angle: 5.1±4.0%; p=0.003). Unlike arm swing magnitude, arm swing asymmetry unequivocally differs between people with early PD and controls. Such quantitative evaluation of arm swing, especially its asymmetry, may have utility for early and differential diagnosis, and for tracking disease progression in patients with later PD. PMID:19945285

  7. Linking Publications to Instruments, Field Campaigns, Sites and Working Groups: The ARM Experience

    NASA Astrophysics Data System (ADS)

    Lehnert, K.; Parsons, M. A.; Ramachandran, R.; Fils, D.; Narock, T.; Fox, P. A.; Troyan, D.; Cialella, A. T.; Gregory, L.; Lazar, K.; Liang, M.; Ma, L.; Tilp, A.; Wagener, R.

    2017-12-01

    For the past 25 years, the ARM Climate Research Facility - a US Department of Energy scientific user facility - has been collecting atmospheric data in different climatic regimes using both in situ and remote instrumentation. Configuration of the facility's components has been designed to improve the understanding and representation, in climate and earth system models, of clouds and aerosols. Placing a premium on long-term continuous data collection resulted in terabytes of data having been collected, stored, and made accessible to any interested person. All data is accessible via the ARM.gov website and the ARM Data Discovery Tool. A team of metadata professionals assign appropriate tags to help facilitate searching the databases for desired data. The knowledge organization tools and concepts are used to create connections between data, instruments, field campaigns, sites, and measurements are familiar to informatics professionals. Ontology, taxonomy, classification, and thesauri are among the customized concepts put into practice for ARM's purposes. In addition to the multitude of data available, there have been approximately 3,000 journal articles that utilize ARM data. These have been linked to specific ARM web pages. Searches of the complete ARM publication database can be done using a separate interface. This presentation describes how ARM data is linked to instruments, sites, field campaigns, and publications through the application of standard knowledge organization tools and concepts.

  8. Using virtual reality environment to facilitate training with advanced upper-limb prosthesis.

    PubMed

    Resnik, Linda; Etter, Katherine; Klinger, Shana Lieberman; Kambe, Charles

    2011-01-01

    Technological advances in upper-limb prosthetic design offer dramatically increased possibilities for powered movement. The DEKA Arm system allows users 10 powered degrees of movement. Learning to control these movements by utilizing a set of motions that, in most instances, differ from those used to obtain the desired action prior to amputation is a challenge for users. In the Department of Veterans Affairs "Study to Optimize the DEKA Arm," we attempted to facilitate motor learning by using a virtual reality environment (VRE) program. This VRE program allows users to practice controlling an avatar using the controls designed to operate the DEKA Arm in the real world. In this article, we provide highlights from our experiences implementing VRE in training amputees to use the full DEKA Arm. This article discusses the use of VRE in amputee rehabilitation, describes the VRE system used with the DEKA Arm, describes VRE training, provides qualitative data from a case study of a subject, and provides recommendations for future research and implementation of VRE in amputee rehabilitation. Our experience has led us to believe that training with VRE is particularly valuable for upper-limb amputees who must master a large number of controls and for those amputees who need a structured learning environment because of cognitive deficits.

  9. Light duty utility arm phase 2 qualification test procedure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barnes, G.A.

    1997-01-16

    This Acceptance Test Procedure (ATP) will test and verify that the Exhauster meets the specified functional requirements, safety requirements, operating requirements, and provide a record of the functional test results. The system/functions that will be tested are listed in the scope section of the Acceptance Test Procedure.

  10. Dual liquid and gas chromatograph system

    DOEpatents

    Gay, D.D.

    A chromatographic system is described that utilizes one detection system for gas chromatographic and micro-liquid chromatographic determinations. The detection system is a direct-current, atmospheric-pressure, helium plasma emission spectrometer. The detector utilizes a nontransparent plasma source unit which contains the plasma region and two side-arms which receive effluents from the micro-liquid chromatograph and the gas chromatograph. The dual nature of this chromatographic system offers: (1) extreme flexibility in the samples to be examined; (2) extreme low sensitivity; (3) element selectivity; (4) long-term stability; (5) direct correlation of data from the liquid and gas samples; (6) simpler operation than with individual liquid and gas chromatographs, each with different detection systems; and (7) cheaper than a commercial liquid chromatograph and a gas chromatograph.

  11. Dual liquid and gas chromatograph system

    DOEpatents

    Gay, Don D.

    1985-01-01

    A chromatographic system that utilizes one detection system for gas chromatographic and micro-liquid chromatographic determinations. The detection system is a direct-current, atmospheric-pressure, helium plasma emission spectrometer. The detector utilizes a non-transparent plasma source unit which contains the plasma region and two side-arms which receive effluents from the micro-liquid chromatograph and the gas chromatograph. The dual nature of this chromatographic system offers: (1) extreme flexibility in the samples to be examined; (2) extremely low sensitivity; (3) element selectivity; (4) long-term stability; (5) direct correlation of data from the liquid and gas samples; (6) simpler operation than with individual liquid and gas chromatographs, each with different detection systems; and (7) cheaper than a commercial liquid chromatograph and a gas chromatograph.

  12. Microelectromechanical safe arm device

    DOEpatents

    Roesler, Alexander W [Tijeras, NM

    2012-06-05

    Microelectromechanical (MEM) apparatus and methods for operating, for preventing unintentional detonation of energetic components comprising pyrotechnic and explosive materials, such as air bag deployment systems, munitions and pyrotechnics. The MEM apparatus comprises an interrupting member that can be moved to block (interrupt) or complete (uninterrupt) an explosive train that is part of an energetic component. One or more latching members are provided that engage and prevent the movement of the interrupting member, until the one or more latching members are disengaged from the interrupting member. The MEM apparatus can be utilized as a safe and arm device (SAD) and electronic safe and arm device (ESAD) in preventing unintentional detonations. Methods for operating the MEM apparatus include independently applying drive signals to the actuators coupled to the latching members, and an actuator coupled to the interrupting member.

  13. 3D Measurement of Forearm and Upper Arm during Throwing Motion using Body Mounted Sensor

    NASA Astrophysics Data System (ADS)

    Koda, Hideharu; Sagawa, Koichi; Kuroshima, Kouta; Tsukamoto, Toshiaki; Urita, Kazutaka; Ishibashi, Yasuyuki

    The aim of this study is to propose the measurement method of three-dimensional (3D) movement of forearm and upper arm during pitching motion of baseball using inertial sensors without serious consideration of sensor installation. Although high accuracy measurement of sports motion is achieved by using optical motion capture system at present, it has some disadvantages such as the calibration of cameras and limitation of measurement place. Whereas the proposed method for 3D measurement of pitching motion using body mounted sensors provides trajectory and orientation of upper arm by the integration of acceleration and angular velocity measured on upper limb. The trajectory of forearm is derived so that the elbow joint axis of forearm corresponds to that of upper arm. Spatial relation between upper limb and sensor system is obtained by performing predetermined movements of upper limb and utilizing angular velocity and gravitational acceleration. The integration error is modified so that the estimated final position, velocity and posture of upper limb agree with the actual ones. The experimental results of the measurement of pitching motion show that trajectories of shoulder, elbow and wrist estimated by the proposed method are highly correlated to those from the motion capture system within the estimation error of about 10 [%].

  14. Incorporating haptic effects into three-dimensional virtual environments to train the hemiparetic upper extremity

    PubMed Central

    Adamovich, Sergei; Fluet, Gerard G.; Merians, Alma S.; Mathai, Abraham; Qiu, Qinyin

    2010-01-01

    Current neuroscience has identified several constructs to increase the effectiveness of upper extremity rehabilitation. One is the use of progressive, skill acquisition-oriented training. Another approach emphasizes the use of bilateral activities. Building on these principles, this paper describes the design and feasibility testing of a robotic / virtual environment system designed to train the arm of persons who have had strokes. The system provides a variety of assistance modes, scalable workspaces and hand-robot interfaces allowing persons with strokes to train multiple joints in three dimensions. The simulations utilize assistance algorithms that adjust task difficulty both online and offline in relation to subject performance. Several distinctive haptic effects have been incorporated into the simulations. An adaptive master-slave relationship between the unimpaired and impaired arm encourages active movement of the subject's hemiparetic arm during a bimanual task. Adaptive anti-gravity support and damping stabilize the arm during virtual reaching and placement tasks. An adaptive virtual spring provides assistance to complete the movement if the subject is unable to complete the task in time. Finally, haptically rendered virtual objects help to shape the movement trajectory during a virtual placement task. A proof of concept study demonstrated this system to be safe, feasible and worthy of further study. PMID:19666345

  15. The STAMPEDE trial: paradigm-changing data through innovative trial design.

    PubMed

    Carthon, Bradley C; Antonarakis, Emmanuel S

    2016-09-01

    Despite the numerous regulatory approvals for prostate cancer, metastatic prostate cancer remains a huge burden for men worldwide. In an exciting development, James et al . recently published data from the Systemic Therapy in Advanced or Metastatic Prostate Cancer: Evaluation of Drug Efficacy: a multi-stage multi-arm randomised control trial (STAMPEDE). This is an innovative multi-arm multi-stage (MAMS) trial that has utilized one control arm and several comparator arms in order to provide evidence for the inclusion of therapies beyond standard androgen deprivation alone. The patient population included: (I) men with high-risk, non-metastatic, node-negative disease; (II) men with distant-metastatic or node-positive disease; and (III) men with previously-treated prostate cancer by prostatectomy or definitive radiotherapy presenting with relapse. Men were to continue androgen deprivation for at least 2 years. The current data published by this group supports earlier results and provides additional evidence that docetaxel utilized in an up-front fashion provides a survival benefit in men with hormone-sensitive metastatic prostate cancer. Moreover, the initial results from STAMPEDE show how therapies without a demonstrated survival benefit can be efficiently excluded from further study once the likelihood of a benefit is ruled out by a predetermined analysis. In this piece, we will review the STAMPEDE data, contrast it with existing results, and provide our perspectives on how this will affect future trial conduct in the field of prostate cancer.

  16. Summary of compliant and multi-arm control at NASA. Langley Research Center

    NASA Technical Reports Server (NTRS)

    Harrison, Fenton W.

    1992-01-01

    The topics are presented in viewgraph form and include the: single arm system, single arm axis system, single arm control systems, single arm hand controller axis system, single arm position axis system, single arm vision axis system, single arm force axis system, multi-arm system, multi-arm axis system, and the dual arm hand control axis system with control signals.

  17. Utilization of robotic-arm assisted total knee arthroplasty for soft tissue protection.

    PubMed

    Sultan, Assem A; Piuzzi, Nicolas; Khlopas, Anton; Chughtai, Morad; Sodhi, Nipun; Mont, Michael A

    2017-12-01

    Despite the well-established success of total knee arthroplasty (TKA), iatrogenic ligamentous and soft tissue injuries are infrequent, but potential complications that can have devastating impact on clinical outcomes. These injuries are often related to technical errors and excessive soft tissue manipulation, particularly during bony resections. Recently, robotic-arm assisted TKA was introduced and demonstrated promising results with potential technical advantages over manual surgery in implant positioning and mechanical accuracy. Furthermore, soft tissue protection is an additional potential advantage offered by these systems that can reduce inadvertent human technical errors encountered during standard manual resections. Therefore, due to the relative paucity of literature, we attempted to answer the following questions: 1) does robotic-arm assisted TKA offer a technical advantage that allows enhanced soft tissue protection? 2) What is the available evidence about soft tissue protection? Recently introduced models of robotic-arm assisted TKA systems with advanced technology showed promising clinical outcomes and soft tissue protection in the short- and mid-term follow-up with results comparable or superior to manual TKA. In this review, we attempted to explore this dimension of robotics in TKA and investigate the soft tissue related complications currently reported in the literature.

  18. No moving parts safe & arm apparatus and method with monitoring and built-in-test for optical firing of explosive systems

    DOEpatents

    Hendrix, J.L.

    1995-04-11

    A laser initiated ordnance controller apparatus which provides a safe and arm scheme with no moving parts. The safe & arm apparatus provides isolation of firing energy to explosive devices using a combination of polarization isolation and control through acousto-optical deviation of laser energy pulses. The apparatus provides constant monitoring of the systems status and performs 100% built-in-test at any time prior to ordnance ignition without the risk of premature ignition or detonation. The apparatus has a computer controller, a solid state laser, an acousto-optic deflector and RF drive circuitry, built-in-test optics and electronics, and system monitoring capabilities. The optical system is completed from the laser beam power source to the pyrotechnic ordnance through fiber optic cabling, optical splitters and optical connectors. During operation of the apparatus, a command is provided by the computer controller and, simultaneous with laser flashlamp fire, the safe & arm device is opened for approximately 200 microseconds which allows the laser pulse to transmit through the device. The arm signal also energizes the laser power supply and activates the acousto-optical deflector. When the correct fire format command is received, the acousto-optic deflector moves to the selected event channel, and the channel is verified to ensure the system is pointing to the correct position. Laser energy is transmitted through the fiber where an ignitor or detonator designed to be sensitive to optical pulses is fired at the end of the fiber channel. Simultaneous event channels may also be utilized by optically splitting a single event channel. The built-in-test may be performed anytime prior to ordnance ignition. 6 figures.

  19. Asteroid Redirect Mission Concept: A Bold Approach for Utilizing Space Resources

    NASA Technical Reports Server (NTRS)

    Mazanek, Daniel D.; Merrill, Raymond G.; Brophy, John R.; Mueller, Robert P.

    2014-01-01

    The utilization of natural resources from asteroids is an idea that is older than the Space Age. The technologies are now available to transform this endeavour from an idea into reality. The Asteroid Redirect Mission (ARM) is a mission concept which includes the goal of robotically returning a small Near-Earth Asteroid (NEA) or a multi-ton boulder from a large NEA to cislunar space in the mid 2020's using an advanced Solar Electric Propulsion (SEP) vehicle and currently available technologies. The paradigm shift enabled by the ARM concept would allow in-situ resource utilization (ISRU) to be used at the human mission departure location (i.e., cislunar space) versus exclusively at the deep-space mission destination. This approach drastically reduces the barriers associated with utilizing ISRU for human deep-space missions. The successful testing of ISRU techniques and associated equipment could enable large-scale commercial ISRU operations to become a reality and enable a future space-based economy utilizing processed asteroidal materials. This paper provides an overview of the ARM concept and discusses the mission objectives, key technologies, and capabilities associated with the mission, as well as how the ARM and associated operations would benefit humanity's quest for the exploration and settlement of space.

  20. Type III CRISPR-Cas systems can provide redundancy to counteract viral escape from type I systems.

    PubMed

    Silas, Sukrit; Lucas-Elio, Patricia; Jackson, Simon A; Aroca-Crevillén, Alejandra; Hansen, Loren L; Fineran, Peter C; Fire, Andrew Z; Sánchez-Amat, Antonio

    2017-08-17

    CRISPR-Cas-mediated defense utilizes information stored as spacers in CRISPR arrays to defend against genetic invaders. We define the mode of target interference and role in antiviral defense for two CRISPR-Cas systems in Marinomonas mediterranea . One system (type I-F) targets DNA. A second system (type III-B) is broadly capable of acquiring spacers in either orientation from RNA and DNA, and exhibits transcription-dependent DNA interference. Examining resistance to phages isolated from Mediterranean seagrass meadows, we found that the type III-B machinery co-opts type I-F CRISPR-RNAs. Sequencing and infectivity assessments of related bacterial and phage strains suggests an 'arms race' in which phage escape from the type I-F system can be overcome through use of type I-F spacers by a horizontally-acquired type III-B system. We propose that the phage-host arms race can drive selection for horizontal uptake and maintenance of promiscuous type III interference modules that supplement existing host type I CRISPR-Cas systems.

  1. Utilization of a Terrestrial Laser Scanner for the Calibration of Mobile Mapping Systems

    PubMed Central

    Hong, Seunghwan; Park, Ilsuk; Lee, Jisang; Lim, Kwangyong; Choi, Yoonjo; Sohn, Hong-Gyoo

    2017-01-01

    This paper proposes a practical calibration solution for estimating the boresight and lever-arm parameters of the sensors mounted on a Mobile Mapping System (MMS). On our MMS devised for conducting the calibration experiment, three network video cameras, one mobile laser scanner, and one Global Navigation Satellite System (GNSS)/Inertial Navigation System (INS) were mounted. The geometric relationships between three sensors were solved by the proposed calibration, considering the GNSS/INS as one unit sensor. Our solution basically uses the point cloud generated by a 3-dimensional (3D) terrestrial laser scanner rather than using conventionally obtained 3D ground control features. With the terrestrial laser scanner, accurate and precise reference data could be produced and the plane features corresponding with the sparse mobile laser scanning data could be determined with high precision. Furthermore, corresponding point features could be extracted from the dense terrestrial laser scanning data and the images captured by the video cameras. The parameters of the boresight and the lever-arm were calculated based on the least squares approach and the precision of the boresight and lever-arm could be achieved by 0.1 degrees and 10 mm, respectively. PMID:28264457

  2. [Mental Health Stigma: An Influencing Factor in Healthcare Utilization by Veterans of the German Armed Forces].

    PubMed

    Schuy, Katrin; Brants, Loni M; Dors, Simone; Ströhle, Andreas; Zimmermann, Peter Lutz; Willmund, Gerd Dieter; Rau, Heinrich; Siegel, Stefan

    2018-05-14

     Mental illness stigma is a barrier to healthcare utilization. This study is the first to research the connection between mental illness stigma and the use of healthcare by veterans of the German Armed Forces. An overview of perceived stigma components in this sample is provided that should help understand how these factors influence healthcare utilization.  43 interviews with veterans of the German Armed Forces were conducted. The resulting data were analyzed in several coding steps. It was investigated whether the stigma experience of veterans of the German Armed Forces could be well illustrated by the theory-based stigmatization model of Link and Phelan. A set of hypotheses on stigma and healthcare utilization based on the data were developed.  All stigma components according to the model of Link and Phelan were found in the sample. Internalized stigma, perceived public stigmatization, vocational disadvantage and social exclusion as well as feared misunderstanding of the military past in the civilian sector were reported as main stigma-relevant barriers to the use of healthcare.  Recommendations for interventions are given to decrease mental illness stigma in this specific group of former soldiers. © Georg Thieme Verlag KG Stuttgart · New York.

  3. The Importance of the Effective Utilization of Women at Arms

    DTIC Science & Technology

    2015-03-01

    Network Presented in Zagreb ,” South Eastern and Eastern Europe Clearinghouse for the Control of Small Arms and Light Weapons, November 5, 2010, http...for the Control of Small Arms and Light Weapons. “Report Establishing the South East Europe Women Police Officers Network Presented in Zagreb

  4. TRAVIS AND ARMS REVISITED: A SECOND LOOK AT A WIDELY USED BIOCONCENTRATION ALGORITHM

    EPA Science Inventory

    In 1988, Travis and Arms reviewed the literature and collected data to develop a relationship between the octanolwater partition coefficient (Kow) and the uptake of organic compounds into milk and beef (Travis and Arms, 1988). These equations have been utilized for predicting bio...

  5. Economic evaluation of a task-shifting intervention for common mental disorders in India

    PubMed Central

    Buttorff, Christine; Hock, Rebecca S; Weiss, Helen A; Naik, Smita; Araya, Ricardo; Kirkwood, Betty R; Chisholm, Daniel

    2012-01-01

    Abstract Objective To carry out an economic evaluation of a task-shifting intervention for the treatment of depressive and anxiety disorders in primary-care settings in Goa, India. Methods Cost–utility and cost–effectiveness analyses based on generalized linear models were performed within a trial set in 24 public and private primary-care facilities. Subjects were randomly assigned to an intervention or a control arm. Eligible subjects in the intervention arm were given psycho-education, case management, interpersonal psychotherapy and/or antidepressants by lay health workers. Subjects in the control arm were treated by physicians. The use of health-care resources, the disability of each subject and degree of psychiatric morbidity, as measured by the Revised Clinical Interview Schedule, were determined at 2, 6 and 12 months. Findings Complete data, from all three follow-ups, were collected from 1243 (75.4%) and 938 (81.7%) of the subjects enrolled in the study facilities from the public and private sectors, respectively. Within the public facilities, subjects in the intervention arm showed greater improvement in all the health outcomes investigated than those in the control arm. Time costs were also significantly lower in the intervention arm than in the control arm, whereas health system costs in the two arms were similar. Within the private facilities, however, the effectiveness and costs recorded in the two arms were similar. Conclusion Within public primary-care facilities in Goa, the use of lay health workers in the care of subjects with common mental disorders was not only cost–effective but also cost-saving. PMID:23226893

  6. A randomised controlled trial evaluating the utility of a patient Decision Aid to improve clinical trial (RAVES 08.03) related decision-making.

    PubMed

    Sundaresan, Puma; Ager, Brittany; Turner, Sandra; Costa, Dan; Kneebone, Andrew; Pearse, Maria; Woo, Henry; Tesson, Stephanie; Juraskova, Ilona; Butow, Phyllis

    2017-10-01

    Randomised controlled trials (RCTs) are considered the 'gold-standard' for evaluating medical treatments. However, patients and clinicians report difficulties with informed consent and recruitment. We evaluated the utility of a Decision Aid (DA) in reducing RCT-related decisional conflict, and improving RCT knowledge and recruitment. Potential participants for a radiotherapy RCT were invited to participate in the current study. Participants were randomised to receive the RCT's participant information sheet with or without a DA. Questionnaires were administered at baseline, one and six months. The primary outcome measure was decisional conflict. Secondary outcome measures included knowledge regarding and recruitment to the RCT. 129 men were randomised to the DA (63) and control (66) arms. Decisional conflict was significantly lower over 6-months (p=0.048) in the DA arm. Knowledge regarding the RCT was significantly higher at 6months (p=0.033) in the DA arm. 20.6% of the DA arm (13 of 63) and 9% of the control arm (6 of 66) entered the RCT. This study demonstrates the utility of a DA in reducing decisional conflict and improving trial knowledge in men with cancer who are making decisions regarding RCT participation. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  7. [Management of war orthopaedic injuries in recent armed conflicts].

    PubMed

    Frank, M; Mathieu, L

    2013-01-01

    The extremities continue to be the most frequent sites of wounding during armed conflicts despite the change of combat tactics, soldier armour and battlefield medical support. Due to the advances in prehospital care and timely transport to the hospital, orthopaedic surgeons deal with severe and challenging injuries of the limbs. In contrast to civilian extremity trauma, the most combat-related injuries are open wounds that often have infection-related complications. Data from two recent large armed conflicts (Iraq, Afghanistan) show that extremity injuries are associated with a high complication rate, morbidity and healthcare utilization. A systematic approach that consists of sequential surgical care and good transport capabilities can reduce the complication rate of these injuries. New medical technologies have been implemented in the treatment strategy during the last decade. This article reviews the published scientific data and current opinions on combat-related extremity injuries. Key words: extremity, combat, trauma, medical support system.

  8. Soldier’s Load and the Multifunctional Utility/Logistics and Equipment-Transport

    DTIC Science & Technology

    2010-06-11

    Utility/Logistics Equipment-Countermine and an armed reconnaissance variant called the Armed Robotic Vehicle-Assault (Light). All three Lockheed...mission and requires various levels of human- robot interaction (National Institute of Standards and Technology 2004, 14). Teleoperation. A mode of...use of robots as an act of cowardice, especially in cultures which hold in high esteem the nobility of sacrificing oneself for a higher purpose (Singer

  9. The Asteroid Redirect Mission (ARM): Exploration of a Former Binary NEA?

    NASA Technical Reports Server (NTRS)

    Abell, P. A.; Mazanek, D. D.; Reeves, D. M.; Chodas, P. W.; Gates, M. M.; Johnson, L. N.; Ticker, R. L.

    2016-01-01

    The National Aeronautics and Space Administration (NASA) is developing the Asteroid Redirect Mission (ARM) as a capability demonstration for future human exploration, including use of high-power solar electric propulsion, which allows for the efficient movement of large masses through deep space. The ARM will also demonstrate the capability to conduct proximity operations with natural space objects and crewed operations beyond the security of quick Earth return. The Asteroid Redirect Robotic Mission (ARRM), currently in formulation, will visit a large near-Earth asteroid (NEA), collect a multi-ton boulder from its surface, conduct a demonstration of a slow push planetary defense technique, and redirect the multi-ton boulder into a stable orbit around the Moon. Once returned to cislunar space in the mid-2020s, astronauts aboard an Orion spacecraft will dock with the robotic vehicle to explore the boulder and return samples to Earth. The ARM is part of NASA's plan to advance technologies, capabilities, and spaceflight experience needed for a human mission to the Martian system in the 2030s. The ARM and subsequent availability of the asteroidal material in cis-lunar space, provide significant opportunities to advance our knowledge of small bodies in the synergistic areas of science, planetary defense, and in-situ resource utilization (ISRU). The current reference target for the ARM is NEA (341843) 2008 EV5, which may have been the primary body of a former binary system (Busch et al., 2011; Tardivel et al., 2016). The ARRM will perform several close proximity operations to investigate the NEA and map its surface. A detailed investigation of this object may allow a better understanding of binary NEA physical characteristics and the possible outcomes for their evolution. An overview of the ARM robotic and crewed segments, including mission operations, and a discussion of potential opportunities for participation with the ARM will be provided in this presentation.

  10. Type III CRISPR-Cas systems can provide redundancy to counteract viral escape from type I systems

    PubMed Central

    Silas, Sukrit; Lucas-Elio, Patricia; Jackson, Simon A; Aroca-Crevillén, Alejandra; Hansen, Loren L; Fineran, Peter C

    2017-01-01

    CRISPR-Cas-mediated defense utilizes information stored as spacers in CRISPR arrays to defend against genetic invaders. We define the mode of target interference and role in antiviral defense for two CRISPR-Cas systems in Marinomonas mediterranea. One system (type I-F) targets DNA. A second system (type III-B) is broadly capable of acquiring spacers in either orientation from RNA and DNA, and exhibits transcription-dependent DNA interference. Examining resistance to phages isolated from Mediterranean seagrass meadows, we found that the type III-B machinery co-opts type I-F CRISPR-RNAs. Sequencing and infectivity assessments of related bacterial and phage strains suggests an ‘arms race’ in which phage escape from the type I-F system can be overcome through use of type I-F spacers by a horizontally-acquired type III-B system. We propose that the phage-host arms race can drive selection for horizontal uptake and maintenance of promiscuous type III interference modules that supplement existing host type I CRISPR-Cas systems. PMID:28826484

  11. Arm-in-Arm Response Regulator Dimers Promote Intermolecular Signal Transduction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, Anna W.; Satyshur, Kenneth A.; Moreno Morales, Neydis

    2016-02-01

    ABSTRACT Bacteriophytochrome photoreceptors (BphPs) and their cognate response regulators make up two-component signal transduction systems which direct bacteria to mount phenotypic responses to changes in environmental light quality. Most of these systems utilize single-domain response regulators to transduce signals through unknown pathways and mechanisms. Here we describe the photocycle and autophosphorylation kinetics of RtBphP1, a red light-regulated histidine kinase from the desert bacteriumRamlibacter tataouinensis. RtBphP1 undergoes red to far-red photoconversion with rapid thermal reversion to the dark state. RtBphP1 is autophosphorylated in the dark; this activity is inhibited under red light. The RtBphP1 cognate response regulator, theR. tataouinensisbacteriophytochrome response regulatormore » (RtBRR), and a homolog, AtBRR fromAgrobacterium tumefaciens, crystallize unexpectedly as arm-in-arm dimers, reliant on a conserved hydrophobic motif, hFWAhL (where h is a hydrophobic M, V, L, or I residue). RtBRR and AtBRR dimerize distinctly from four structurally characterized phytochrome response regulators found in photosynthetic organisms and from all other receiver domain homodimers in the Protein Data Bank. A unique cacodylate-zinc-histidine tag metal organic framework yielded single-wavelength anomalous diffraction phases and may be of general interest. Examination of the effect of the BRR stoichiometry on signal transduction showed that phosphorylated RtBRR is accumulated more efficiently than the engineered monomeric RtBRR (RtBRR mon) in phosphotransfer reactions. Thus, we conclude that arm-in-arm dimers are a relevant signaling intermediate in this class of two-component regulatory systems. IMPORTANCEBphP histidine kinases and their cognate response regulators comprise widespread red light-sensing two-component systems. Much work on BphPs has focused on structural understanding of light sensing and on enhancing the natural infrared fluorescence of these proteins, rather than on signal transduction or the resultant phenotypes. To begin to address this knowledge gap, we solved the crystal structures of two single-domain response regulators encoded by a region immediately downstream of that encoding BphPs. We observed a previously unknown arm-in-arm dimer linkage. Monomerization via deletion of the C-terminal dimerization motif had an inhibitory effect on net response regulator phosphorylation, underlining the importance of these unusual dimers for signal transduction.« less

  12. Coordination of dual robot arms using kinematic redundancy

    NASA Technical Reports Server (NTRS)

    Suh, Il Hong; Shin, Kang G.

    1988-01-01

    A method is developed to coordinate the motion of dual robot arms carrying a solid object, where the first robot (leader) grasps one end of the object rigidly and the second robot (follower) is allowed to change its grasping position at the other end of the object along the object surface while supporting the object. It is shown that this flexible grasping is equivalent to the addition of one more degree of freedom (dof), giving the follower more maneuvering capabilities. In particular, motion commands for the follower are generated by using kinematic redundancy. To show the utility and power of the method, an example system with two PUMA 560 robots carrying a beam is analyzed.

  13. Electrically Stimulated Antagonist Muscle Contraction Increased Muscle Mass and Bone Mineral Density of One Astronaut - Initial Verification on the International Space Station

    PubMed Central

    Takano, Yoshio; Yoshimitsu, Kazuhiro; Omoto, Masayuki; Hashida, Ryuki; Tagawa, Yoshihiko; Inada, Tomohisa; Yamada, Shin; Ohshima, Hiroshi

    2015-01-01

    Background Musculoskeletal atrophy is one of the major problems of extended periods of exposure to weightlessness such as on the International Space Station (ISS). We developed the Hybrid Training System (HTS) to maintain an astronaut’s musculoskeletal system using an electrically stimulated antagonist to resist the volitional contraction of the agonist instead of gravity. The present study assessed the system’s orbital operation capability and utility, as well as its preventative effect on an astronaut’s musculoskeletal atrophy. Methods HTS was attached to the non-dominant arm of an astronaut staying on the ISS, and his dominant arm without HTS was established as the control (CTR). 10 sets of 10 reciprocal elbow curls were one training session, and 12 total sessions of training (3 times per week for 4 weeks) were performed. Pre and post flight ground based evaluations were performed by Biodex (muscle performance), MRI (muscle volume), and DXA (BMD, lean [muscle] mass, fat mass). Pre and post training inflight evaluations were performed by a hand held dynamometer (muscle force) and a measuring tape (upper arm circumference). Results The experiment was completed on schedule, and HTS functioned well without problems. Isokinetic elbow extension torque (Nm) changed -19.4% in HTS, and -21.7% in CTR. Isokinetic elbow flexion torque changed -23.7% in HTS, and there was no change in CTR. Total Work (Joule) of elbow extension changed -8.3% in HTS, and +0.3% in CTR. For elbow flexion it changed -23.3% in HTS and -32.6% in CTR. Average Power (Watts) of elbow extension changed +22.1% in HTS and -8.0% in CTR. For elbow flexion it changed -6.5% in HTS and -4.8% in CTR. Triceps muscle volume according to MRI changed +11.7% and that of biceps was +2.1% using HTS, however -0.1% and -0.4% respectively for CTR. BMD changed +4.6% in the HTS arm and -1.2% for CTR. Lean (muscle) mass of the arm changed only +10.6% in HTS. Fat mass changed -12.6% in HTS and -6.4% in CTR. Conclusions These results showed the orbital operation capability and utility, and the preventive effect of HTS for an astronaut’s musculoskeletal atrophy. The initial flight data together with the ground data obtained so far will be utilized in the future planning of human space exploration. PMID:26296204

  14. Comparison of two plethysmography systems in assessment of forearm blood flow.

    PubMed

    Leslie, Stephen J; Attinà, Teresa; Hultsch, Ellen; Bolscher, Luc; Grossman, Matthias; Denvir, Martin A; Webb, David J

    2004-05-01

    Venous occlusion plethysmography is widely used to assess forearm blood flow (FBF). We compared the established Hokanson system (HEC4) with a newly developed Filtrass 2001 system (F2001). The HEC4 uses mercury-in-Silastic strain gauges, whereas F2001 detects volume changes with a nonmercury linear displacement device. The aim of this study was to evaluate the new F2001 against the HEC4 in terms of repeatability and systematic bias. Ten subjects were studied on 4 separate days in random order using either the HEC4 on both arms, the F2001 on both arms, the HEC4 on the right arm with the F2001 on the left, or the F2001 on the right arm and the HEC4 on the left. Stroop's colored word conflict test and postocclusive hyperemia were used to increase FBF, and lower body negative pressure was used to lower FBF. Stroop's colored word conflict test and lower body negative pressure increased (24.6 +/- 1.5%, n = 240, P < 0.0001) and decreased (18.7 +/- 0.8%, n = 240, P < 0.0001) FBF, respectively. Postocclusive hyperemia after occlusion times of 5, 8, and 13 min substantially increased FBF by 390 +/- 86, 756 +/- 217, and 851 +/- 132%, respectively. Repeatability was not different between the devices (0.10 +/- 2.37 vs. -0.47 +/- 1.92 l/min, n = 125, P > 0.05), and there was no systematic bias. The F2001 is a newly developed plethysmography system that does not utilize mercury and is suitable for assessing changes of FBF in physiological studies.

  15. In vivo visualization of robotically implemented synthetic tracked aperture ultrasound (STRATUS) imaging system using curvilinear array

    NASA Astrophysics Data System (ADS)

    Zhang, Haichong K.; Aalamifar, Fereshteh; Boctor, Emad M.

    2016-04-01

    Synthetic aperture for ultrasound is a technique utilizing a wide aperture in both transmit and receive to enhance the ultrasound image quality. The limitation of synthetic aperture is the maximum available aperture size limit determined by the physical size of ultrasound probe. We propose Synthetic-Tracked Aperture Ultrasound (STRATUS) imaging system to overcome the limitation by extending the beamforming aperture size through ultrasound probe tracking. With a setup involving a robotic arm, the ultrasound probe is moved using the robotic arm, while the positions on a scanning trajectory are tracked in real-time. Data from each pose are synthesized to construct a high resolution image. In previous studies, we have demonstrated the feasibility through phantom experiments. However, various additional factors such as real-time data collection or motion artifacts should be taken into account when the in vivo target becomes the subject. In this work, we build a robot-based STRATUS imaging system with continuous data collection capability considering the practical implementation. A curvilinear array is used instead of a linear array to benefit from its wider capture angle. We scanned human forearms under two scenarios: one submerged the arm in the water tank under 10 cm depth, and the other directly scanned the arm from the surface. The image contrast improved 5.51 dB, and 9.96 dB for the underwater scan and the direct scan, respectively. The result indicates the practical feasibility of STRATUS imaging system, and the technique can be potentially applied to the wide range of human body.

  16. NASA's Asteroid Redirect Mission (ARM)

    NASA Astrophysics Data System (ADS)

    Abell, Paul; Mazanek, Dan; Reeves, David; Naasz, Bo; Cichy, Benjamin

    2015-11-01

    The National Aeronautics and Space Administration (NASA) is developing a robotic mission to visit a large near-Earth asteroid (NEA), collect a multi-ton boulder from its surface, and redirect it into a stable orbit around the Moon. Once returned to cislunar space in the mid-2020s, astronauts will explore the boulder and return to Earth with samples. This Asteroid Redirect Mission (ARM) is part of NASA’s plan to advance the technologies, capabilities, and spaceflight experience needed for a human mission to the Martian system in the 2030s. Subsequent human and robotic missions to the asteroidal material would also be facilitated by its return to cislunar space. Although ARM is primarily a capability demonstration mission (i.e., technologies and associated operations), there exist significant opportunities to advance our knowledge of small bodies in the synergistic areas of science, planetary defense, asteroidal resources and in-situ resource utilization (ISRU), and capability and technology demonstrations. In order to maximize the knowledge return from the mission, NASA is organizing an ARM Investigation Team, which is being preceded by the Formulation Assessment and Support Team. These teams will be comprised of scientists, technologists, and other qualified and interested individuals to help plan the implementation and execution of ARM. An overview of robotic and crewed segments of ARM, including the mission requirements, NEA targets, and mission operations, will be provided along with a discussion of the potential opportunities associated with the mission.

  17. The Asteroid Redirect Mission (ARM)

    NASA Technical Reports Server (NTRS)

    Abell, Paul

    2015-01-01

    The National Aeronautics and Space Administration (NASA) is developing a robotic mission to visit a large near-Earth asteroid (NEA), collect a multi-ton boulder from its surface, and redirect it into a stable orbit around the Moon. Once returned to cislunar space in the mid-2020s, astronauts will explore the boulder and return to Earth with samples. This Asteroid Redirect Mission (ARM) is part of NASA's plan to advance the technologies, capabilities, and spaceflight experience needed for a human mission to the Martian system in the 2030s. Subsequent human and robotic missions to the asteroidal material would also be facilitated by its return to cislunar space. Although ARM is primarily a capability demonstration mission (i.e., technologies and associated operations), there exist significant opportunities to advance our knowledge of small bodies in the synergistic areas of science, planetary defense, asteroidal resources and in-situ resource utilization (ISRU), and capability and technology demonstrations. In order to maximize the knowledge return from the mission, NASA is organizing an ARM Investigation Team, which is being preceded by the Formulation Assessment and Support Team. These teams will be comprised of scientists, technologists, and other qualified and interested individuals to help plan the implementation and execution of ARM. An overview of robotic and crewed segments of ARM, including the mission requirements, NEA targets, and mission operations, will be provided along with a discussion of the potential opportunities associated with the mission.

  18. Fuzzy logic applications to expert systems and control

    NASA Technical Reports Server (NTRS)

    Lea, Robert N.; Jani, Yashvant

    1991-01-01

    A considerable amount of work on the development of fuzzy logic algorithms and application to space related control problems has been done at the Johnson Space Center (JSC) over the past few years. Particularly, guidance control systems for space vehicles during proximity operations, learning systems utilizing neural networks, control of data processing during rendezvous navigation, collision avoidance algorithms, camera tracking controllers, and tether controllers have been developed utilizing fuzzy logic technology. Several other areas in which fuzzy sets and related concepts are being considered at JSC are diagnostic systems, control of robot arms, pattern recognition, and image processing. It has become evident, based on the commercial applications of fuzzy technology in Japan and China during the last few years, that this technology should be exploited by the government as well as private industry for energy savings.

  19. The validity and clinical utility of the Disabilities of the Arm Shoulder and Hand questionnaire for hand injuries in developing country contexts: A systematic review.

    PubMed

    de Klerk, Susan; Buchanan, Helen; Jerosch-Herold, Christina

    Systematic review. The Disabilities of the Arm Shoulder and Hand Questionnaire has multiple language versions from many countries around the world. In addition there is extensive research evidence of its psychometric properties. The purpose of this study was to systematically review the evidence available on the validity and clinical utility of the Disabilities of the Arm Shoulder and Hand as a measure of activity and participation in patients with musculoskeletal hand injuries in developing country contexts. We registered the review with international prospective register of systematic reviews prior to conducting a comprehensive literature search and extracting descriptive data. Two reviewers independently assessed methodological quality with the Consensus-Based Standards for the Selection of Health Measurement Instruments critical appraisal tool, the checklist to operationalize measurement characteristics of patient-rated outcome measures and the multidimensional model of clinical utility. Fourteen studies reporting 12 language versions met the eligibility criteria. Two language versions (Persian and Turkish) had an overall rating of good, and one (Thai) had an overall rating of excellent for cross-cultural validity. The remaining 9 language versions had an overall poor rating for cross-cultural validity. Content and construct validity and clinical utility yielded similar results. Poor quality ratings for validity and clinical utility were due to insufficient documentation of results and inadequate psychometric testing. With the increase in migration and globalization, hand therapists are likely to require a range of culturally adapted and translated versions of the Disabilities of the Arm Shoulder and Hand. Recommendations include rigorous application and reporting of cross-cultural adaptation, appropriate psychometric testing, and testing of clinical utility in routine clinical practice. Copyright © 2017 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  20. No moving parts safe & arm apparatus and method with monitoring and built-in-test for optical firing of explosive systems

    DOEpatents

    Hendrix, James L.

    1995-01-01

    A laser initiated ordnance controller apparatus which provides a safe and m scheme with no moving parts. The safe & arm apparatus provides isolation of firing energy to explosive devices using a combination of polarization isolation and control through acousto-optical deviation of laser energy pulses. The apparatus provides constant monitoring of the systems status and performs 100% built-in-test at any time prior to ordnance ignition without the risk of premature ignition or detonation. The apparatus has a computer controller, a solid state laser, an acousto-optic deflector and RF drive circuitry, built-in-test optics and electronics, and system monitoring capabilities. The optical system is completed from the laser beam power source to the pyrotechnic ordnance through fiber optic cabling, optical splitters and optical connectors. During operation of the apparatus, a command is provided by the computer controller and, simultaneous with laser flashlamp fire, the safe & arm device is opened for approximately 200 microseconds which allows the laser pulse to transmit through the device. The arm signal also energizes the laser power supply and activates the acousto-optical deflector. When the correct fire format command is received, the acousto-optic deflector moves to the selected event channel, and the channel is verified to ensure the system is pointing to the correct position. Laser energy is transmitted through the fiber where an ignitor or detonator designed to be sensitive to optical pulses is fired at the end of the fiber channel. Simultaneous event channels may also be utilized by optically splitting a single event channel. The built-in-test may be performed anytime prior to ordnance ignition.

  1. Ethics, rhetoric, and expectations: responsibilities and obligations of health care systems.

    PubMed

    Foreman, Thomas

    2014-09-01

    Health care organization foundations and other fund-raising departments often function at an arm's length from the system at large. As such, operations related to their mandate to raise funds and market the organization do not receive the same level of ethical scrutiny brought to bear on other arms within the organization. An area that could benefit from a more focused ethics lens is the use of language and rhetoric employed in order to raise funds and market the organization. Such departments and divisions often utilize overblown promises of miracles and extraordinary advances to convince donors to contribute and to persuade the general public. The result can be a heightened sense of expectation on the part of patients, their families, and the general public as to what can realistically be achieved by the health care system, leading to disappointment and conflict when these expectations are not or cannot be met. This article suggests that such advertising and marketing be subject to the same advertising standards as other businesses.

  2. A novel technique for ventriculoperitoneal shunting by flat panel detector CT-guided real-time fluoroscopy

    PubMed Central

    Kobayashi, Shinya; Ishikawa, Tatsuya; Mutoh, Tatsushi; Hikichi, Kentaro; Suzuki, Akifumi

    2012-01-01

    Background: Surgical placement of a ventriculoperitoneal shunt (VPS) is the main strategy to manage hydrocephalus. However, the failure rate associated with placement of ventricular catheters remains high. Methods: A hybrid operating room, equipped with a flat-panel detector digital subtraction angiography system containing C-arm cone-beam computed tomography (CB-CT) imaging, has recently been developed and utilized to assist neurosurgical procedures. We have developed a novel technique using intraoperative fluoroscopy and a C-arm CB-CT system to facilitate accurate placement of a VPS. Results: Using this novel technique, 39 consecutive ventricular catheters were placed accurately, and no ventricular catheter failures were experienced during the follow-up period. Only two patients experienced obstruction of the VPS, both of which occurred in the extracranial portion of the shunt system. Conclusion: Surgical placement of a VPS assisted by flat panel detector CT-guided real-time fluoroscopy enabled accurate placement of ventricular catheters and was associated with a decreased need for shunt revision. PMID:23226605

  3. STS-52 CANEX-2 Canadian Target Assembly (CTA) held by RMS over OV-102's PLB

    NASA Image and Video Library

    1992-11-01

    STS052-71-057 (22 Oct-1 Nov 1992) --- This 70mm frame, photographed with a handheld Hasselblad camera aimed through Columbia's aft flight deck windows, captures the operation of the Space Vision System (SVS) experiment above the cargo bay. Target dots have been placed on the Canadian Target Assembly (CTA), a small satellite, in the grasp of the Canadian-built remote manipulator system (RMS) arm. SVS utilized a Shuttle TV camera to monitor the dots strategically arranged on the satellite, to be tracked. As the satellite moved via the arm, the SVS computer measured the changing position of the dots and provided real-time television display of the location and orientation of the CTA. This type of displayed information is expected to help an operator guide the RMS or the Mobile Servicing System (MSS) of the future when berthing or deploying satellites. Also visible in the frame is the U.S. Microgravity Payload (USMP-01).

  4. NASA's Asteroid Redirect Mission: Overview and Status

    NASA Astrophysics Data System (ADS)

    Abell, Paul; Gates, Michele; Johnson, Lindley; Chodas, Paul; Brophy, John; Mazanek, Dan; Muirhead, Brian

    A major element of the National Aeronautics and Space Administration’s (NASA) new Asteroid Initiative is the Asteroid Redirect Mission (ARM). This concept was first proposed in 2011 during a feasibility study at the Keck Institute for Space Studies (KISS)[1] and is under consideration for implementation by NASA. The ARM involves sending a high-efficiency (ISP 3000 s), high-power (40 kW) solar electric propulsion (SEP) robotic vehicle that leverages technology developed by NASA’s Space Technology Mission Directorate (STMD) to rendezvous with a near-Earth asteroid (NEA) and return asteroidal material to a stable lunar distant retrograde orbit (LDRO)[2]. There are two mission concepts currently under study, one that captures an entire 7 - 10 meter mean diameter NEA[3], and another that retrieves a 1 - 10 meter mean diameter boulder from a 100+ meter class NEA[4]. Once the retrieved asteroidal material is placed into the LDRO, a two person crew would launch aboard an Orion capsule to rendezvous and dock with the robotic SEP vehicle. After docking, the crew would conduct two extra-vehicular activities (EVA) to collect asteroid samples and deploy instruments prior to Earth return. The crewed portion of the mission is expected to last approximately 25 days and would represent the first human exploration mission beyond low-Earth orbit (LEO) since the Apollo program. The ARM concept leverages NASA’s activities in Human Exploration, Space Technology, and Planetary Defense to accomplish three primary objectives and several secondary objectives. The primary objective relevant to Human Exploration is to gain operational experience with vehicles, systems, and components that will be utilized for future deep space exploration. In regard to Space Technology, the ARM utilizes advanced SEP technology that has high power and long duration capabilities that enable future missions to deep space destinations, such as the Martian system. With respect to Planetary Defense, the ARM mission will utilize an enhanced NEA observation campaign that will detect, track, and characterize both spacecraft mission targets and potentially hazardous asteroids that may threaten Earth in the future. Potential secondary objectives for ARM include planetary defense demonstrations at the NEA, conducting planetary science (both during the robotic and crewed mission segments), and encouraging commercial and international partnership opportunities. References [1] J. Brophy et al., “Asteroid Retrieval Feasibility Study,” Keck Institute for Space Studies Report, April 2012. [2] N. Strange et al., “Overview of Mission Design for NASA Asteroid Redirect Robotic Mission Concept,” presented at the 33rd International Electric Propulsion Conference, The George Washington University, Washington, D.C., October 2013. [3] B. Muirhead, J. Brophy “Asteroid Redirect Robotic Mission Feasibility Study,” presented at IEEE Aerospace Conference, Big Sky, Montana, March 2014. [4] Mazenek et al., “Asteroid Redirect Robotic Mission: Alternate Concept Overview”, American Institute of Aeronautics and Astronautics, Space 2014 Conference, San Diego, California, August 2014.

  5. Exploiting the Dynamics of Soft Materials for Machine Learning

    PubMed Central

    Hauser, Helmut; Li, Tao; Pfeifer, Rolf

    2018-01-01

    Abstract Soft materials are increasingly utilized for various purposes in many engineering applications. These materials have been shown to perform a number of functions that were previously difficult to implement using rigid materials. Here, we argue that the diverse dynamics generated by actuating soft materials can be effectively used for machine learning purposes. This is demonstrated using a soft silicone arm through a technique of multiplexing, which enables the rich transient dynamics of the soft materials to be fully exploited as a computational resource. The computational performance of the soft silicone arm is examined through two standard benchmark tasks. Results show that the soft arm compares well to or even outperforms conventional machine learning techniques under multiple conditions. We then demonstrate that this system can be used for the sensory time series prediction problem for the soft arm itself, which suggests its immediate applicability to a real-world machine learning problem. Our approach, on the one hand, represents a radical departure from traditional computational methods, whereas on the other hand, it fits nicely into a more general perspective of computation by way of exploiting the properties of physical materials in the real world. PMID:29708857

  6. Exploiting the Dynamics of Soft Materials for Machine Learning.

    PubMed

    Nakajima, Kohei; Hauser, Helmut; Li, Tao; Pfeifer, Rolf

    2018-06-01

    Soft materials are increasingly utilized for various purposes in many engineering applications. These materials have been shown to perform a number of functions that were previously difficult to implement using rigid materials. Here, we argue that the diverse dynamics generated by actuating soft materials can be effectively used for machine learning purposes. This is demonstrated using a soft silicone arm through a technique of multiplexing, which enables the rich transient dynamics of the soft materials to be fully exploited as a computational resource. The computational performance of the soft silicone arm is examined through two standard benchmark tasks. Results show that the soft arm compares well to or even outperforms conventional machine learning techniques under multiple conditions. We then demonstrate that this system can be used for the sensory time series prediction problem for the soft arm itself, which suggests its immediate applicability to a real-world machine learning problem. Our approach, on the one hand, represents a radical departure from traditional computational methods, whereas on the other hand, it fits nicely into a more general perspective of computation by way of exploiting the properties of physical materials in the real world.

  7. Spatial memory: a Rosetta stone for rat and human hippocampal discourse: Theoretical comment on Goodrich-Hunsaker and Hopkins (2010).

    PubMed

    Sutherland, Robert J

    2010-06-01

    The article by Goodrich-Hunsaker and Hopkins (2010, this issue) takes up an important place among in the recent contributions on the role of the hippocampus in memory. They evaluate the effect of bilateral damage to the hippocampus on performance by human participants in a virtual 8-arm radial maze. The hippocampal damage appears to be highly selective and nearly complete. Exactly as with selective hippocampal damage in rats, the human participants showed a deficit in accurately choosing rewarded versus never-rewarded arms and a deficit in avoiding reentering recently visited arms. The results are triply significant: (1) They provide good support for the idea that the wealth of neurobiological information, from network to synapse to gene, on spatial memory in the rat may apply as a whole to the human hippocampal memory system; (2) They affirm the utility of human virtual task models of rat spatial memory tasks; (3) They support one interpretation of the dampening of the hippocampal functional MRI (fMRI) blood oxygen level-dependent (BOLD) signal during performance of the virtual radial arm maze observed by Astur et al. (2005).

  8. Energy from space; Proceedings of the Symposium on Solar Energy from Space, Vienna, Austria, August 9-21, 1982

    NASA Astrophysics Data System (ADS)

    Freeman, J. W.

    Aspects of solar power generation in space are considered. The subjects discussed include: a vision of future energy from space; solar power satellite concept for utilization of energy from space; the institutional challenge of solar power satellites; system study of the solar power satellite concept; market potential and possible limitations for satellite solar power stations; financing a solar power satellite project; and European questions related to satellite power systems. Also addressed are: options and high payoff choices for transportation; an electric propulsion transportation system from low-earth orbit to geostationary orbit utilizing beamed microwave power; the Canadarm robot arm of the Shuttle Remote Manipulator System; an early experimental solar power satellite; power economical considerations for the integration of terrestrial and extraterrestrial solar generators into existing power generation stations; and space solar power in perspective. For individual items see A84-21477 to A84-21489

  9. Recent Weather Extremes and Impacts on Agricultural Production and Vector-Borne Disease Outbreak Patterns

    DTIC Science & Technology

    2014-03-21

    funding from USDA Foreign Agricultural Service towards the Global Agricultural Monitoring project, DoD Armed Forces Health Surveillance Center’s...Global Emerging Infections Surveillance and Response System (AFHSC/GEIS) under the Human Febrile and Vector -Borne Illnesses (FVBI) Program and USDA ...outbreaks during the 2010?2012 period. We utilized 2000?2012 vegetation index and land surface temperature data from NASA ?s satellitebased Moderate

  10. Dementia Care Management in an Underserved Community: The Comparative Effectiveness of Two Different Approaches.

    PubMed

    Chodosh, Joshua; Colaiaco, Benjamin A; Connor, Karen Ilene; Cope, Dennis Wesley; Liu, Hangsheng; Ganz, David Avram; Richman, Mark Jason; Cherry, Debra Lynn; Blank, Joseph Moshe; Carbone, Raquel Del Pilar; Wolf, Sheldon Mark; Vickrey, Barbara Grace

    2015-08-01

    To compare the effectiveness and costs of telephone-only approach to in-person plus telephone for delivering an evidence-based, coordinated care management program for dementia. We randomized 151 patient-caregiver dyads from an underserved predominantly Latino community to two arms that shared a care management protocol but implemented in different formats: in-person visits at home and/or in the community plus telephone and mail, versus telephone and mail only. We compared between-arm caregiver burden and care-recipient problem behaviors (primary outcomes) and patient-caregiver dyad retention, care quality, health care utilization, and costs (secondary outcomes) at 6- and 12-months follow-up. Care quality improved substantially over time in both arms. Caregiver burden, care-recipient problem behaviors, retention, and health care utilization did not differ across arms but the in-person program cost more to deliver. Dementia care quality improved regardless of how care management was delivered; large differences in effectiveness or cost offsets were not detected. © The Author(s) 2015.

  11. Evaluation of a population-level strategy to promote tobacco treatment use among insured smokers: a pragmatic, randomized trial.

    PubMed

    McClure, Jennifer B; Anderson, Melissa L

    2018-02-08

    Most smokers do not use evidence-based smoking cessation treatment. Increasing utilization of these services is an important public health goal. Health care systems and insurers are well positioned to support this goal within their patient populations. We tested whether a brief, mail-based intervention increased utilization of tobacco cessation services among insured smokers. Adult smokers were identified via automated health plan data and randomized to one of five treatment arms (n = 4767). Randomization was stratified by gender, age, and type of health plan coverage. Three arms received a letter containing motivational content and treatment referral information. Motivational content emphasized either the financial, health, or values-based benefits of quitting. One arm received a referral letter with no motivational content, and one arm received no letter. Enrollment in the referred tobacco cessation program was monitored for 5 months. Treatment was available to all participants through their insurance. Across all four letter conditions, 0.8% of participants enrolled in tobacco treatment compared to 0.9% in the no letter reference group (p = .69). No single letter condition was superior to the others (p = .71), but treatment uptake was greater among participants who received their care and coverage from the health plan versus those with insurance coverage only (1.2% vs. 0.3%, p < .01). A one-time, mailed letter is not a cost-effective strategy for promoting use of covered smoking cessation treatment within large health plan populations, particularly when the message source is an insurance provider only and does not also provide clinical care. Health plans and insurers should consider alternative outreach efforts to promote treatment uptake among smokers. TRN registered retrospectively with ISRCTN registry ( www.isrctn.com ). Registered on 11/01/2018. Registration number: ISRCTN32311137 .

  12. Novel system for automatic measuring diopter based on ARM circuit block

    NASA Astrophysics Data System (ADS)

    Xue, Feng; Zhong, Lei; Chen, Zhe; Xue, Deng-pan; Li, Xiang-ning

    2009-07-01

    Traditional commercial instruments utilized in vision screening programs cannot satisfy the request for real-time diopter measurement by far, and their success is limited by some defectiveness such as computer-attached, clumsy volume, and low accuracy of parameters measured, etc. In addition, astigmatic eyes cannot be determined in many devices. This paper proposes a new design of diopter measurement system based on SAMSUNG's ARM9 circuit block. There are several contributions in the design. The new developed system has not only the function of automatically measuring diopter, but also the advantages of the low cost, and especially the simplicity and portability. Besides, by placing point sources in three directions, the instrument can determine astigmatic eyes at the same time. Most of the details are introduced as the integrated design of measuring system, interface circuit of embedded system and so on. Through a preliminary experiment, it is proved that the system keeps good feasibility and validity. The maximum deviation of measurement result is 0.344D.The experimental results also demonstrate the system can provide the service needed for real-time applications. The instrument present here is expected to be widely applied in many fields such as the clinic and home healthcare.

  13. The Orbit of the Companion to HD 100453A: Binary-driven Spiral Arms in a Protoplanetary Disk

    NASA Astrophysics Data System (ADS)

    Wagner, Kevin; Dong, Ruobing; Sheehan, Patrick; Apai, Dániel; Kasper, Markus; McClure, Melissa; Morzinski, Katie M.; Close, Laird; Males, Jared; Hinz, Phil; Quanz, Sascha P.; Fung, Jeffrey

    2018-02-01

    HD 100453AB is a 10 ± 2 Myr old binary whose protoplanetary disk was recently revealed to host a global two-armed spiral structure. Given the relatively small projected separation of the binary (1.″05, or ∼108 au), gravitational perturbations by the binary seemed to be a likely driving force behind the formation of the spiral arms. However, the orbit of these stars remained poorly understood, which prevented a proper treatment of the dynamical influence of the companion on the disk. We observed HD 100453AB between 2015 and 2017, utilizing extreme adaptive optics systems on the Very Large Telescope and the Magellan Clay Telescope. We combined the astrometry from these observations with published data to constrain the parameters of the binary’s orbit to a = 1.″06 ± 0.″09, e = 0.17±0.07, and i = 32.°5 ± 6.°5. We utilized publicly available ALMA 12CO data to constrain the inclination of the disk, {i}{{disk}}∼ 28^\\circ , which is relatively coplanar with the orbit of the companion and consistent with previous estimates from scattered light images. Finally, we input these constraints into hydrodynamic and radiative transfer simulations to model the structural evolution of the disk. We find that the spiral structure and truncation of the circumprimary disk in HD 100453 are consistent with a companion-driven origin. Furthermore, we find that the primary star’s rotation, its outer disk, and the companion exhibit roughly the same direction of angular momentum, and thus the system likely formed from the same parent body of material.

  14. Simulation of aerodynamic noise and vibration noise in hard disk drives

    NASA Astrophysics Data System (ADS)

    Zhu, Lei; Shen, Sheng-Nan; Li, Hui; Zhang, Guo-Qing; Cui, Fu-Hao

    2018-05-01

    Internal flow field characteristics of HDDs are usually influenced by the arm swing during seek operations. This, in turn, can affect aerodynamic noise and airflow-induced noise. In this paper, the dynamic mesh method is used to calculate the flow-induced vibration (FIV) by transient structure analysis and the boundary element method (BEM) is utilized to predict the vibration noise. Two operational states are considered: the arm is fixed and swinging over the disk. Both aerodynamic noise and vibration noise inside drives increase rapidly with increase in disk rotation and arm swing velocities. The largest aerodynamic noise source is always located near the arm and swung with the arm.

  15. Strengthening malaria service delivery through supportive supervision and community mobilization in an endemic Indian setting: an evaluation of nested delivery models.

    PubMed

    Das, Ashis; Friedman, Jed; Kandpal, Eeshani; Ramana, Gandham N V; Gupta, Rudra Kumar Das; Pradhan, Madan M; Govindaraj, Ramesh

    2014-12-08

    Malaria continues to be a prominent global public health challenge. This study tested the effectiveness of two service delivery models for reducing the malaria burden, e.g. supportive supervision of community health workers (CHW) and community mobilization in promoting appropriate health-seeking behaviour for febrile illnesses in Odisha, India. The study population comprised 120 villages from two purposively chosen malaria-endemic districts, with 40 villages randomly assigned to each of the two treatment arms, one with both supportive supervision and community mobilization and one with community mobilization alone, as well as an observational control arm. Outcome measures included changes in the utilization of bed nets and timely care-seeking for fever from a trained provider compared to the control group. Analysis was by intention-to-treat. Significant improvements were observed in the reported utilization of bed nets in both intervention arms (84.5% in arm A and 82.4% in arm B versus 78.6% in the control arm; p < 0.001). While overall rates of treatment-seeking were equal across study arms, treatment-seeking from a CHW was higher in both intervention arms (28%; p = 0.005 and 27.6%; p = 0.007) than in the control arm (19.2%). Fever cases were significantly more likely to visit a CHW and receive a timely diagnosis of fever in the combined interventions arm than in the control arm (82.1% vs. 67.1%; p = 0.025). Care-seeking from trained providers also increased with a substitution away from untrained providers. Further, fever cases from the combined interventions arm (60.6%; p = 0.004) and the community mobilization arm (59.3%; p = 0.012) were more likely to have received treatment from a skilled provider within 24 hours than fever cases from the control arm (50.1%). In particular, women from the combined interventions arm were more likely to have received timely treatment from a skilled provider (61.6% vs. 47.2%; p = 0.028). A community-based intervention combining the supportive supervision of community health workers with intensive community mobilization and can be effective in improving care-seeking and preventive behaviour and may be used to strengthen the national malaria control programme.

  16. Scatter correction using a primary modulator on a clinical angiography C-arm CT system.

    PubMed

    Bier, Bastian; Berger, Martin; Maier, Andreas; Kachelrieß, Marc; Ritschl, Ludwig; Müller, Kerstin; Choi, Jang-Hwan; Fahrig, Rebecca

    2017-09-01

    Cone beam computed tomography (CBCT) suffers from a large amount of scatter, resulting in severe scatter artifacts in the reconstructions. Recently, a new scatter correction approach, called improved primary modulator scatter estimation (iPMSE), was introduced. That approach utilizes a primary modulator that is inserted between the X-ray source and the object. This modulation enables estimation of the scatter in the projection domain by optimizing an objective function with respect to the scatter estimate. Up to now the approach has not been implemented on a clinical angiography C-arm CT system. In our work, the iPMSE method is transferred to a clinical C-arm CBCT. Additional processing steps are added in order to compensate for the C-arm scanner motion and the automatic X-ray tube current modulation. These challenges were overcome by establishing a reference modulator database and a block-matching algorithm. Experiments with phantom and experimental in vivo data were performed to evaluate the method. We show that scatter correction using primary modulation is possible on a clinical C-arm CBCT. Scatter artifacts in the reconstructions are reduced with the newly extended method. Compared to a scan with a narrow collimation, our approach showed superior results with an improvement of the contrast and the contrast-to-noise ratio for the phantom experiments. In vivo data are evaluated by comparing the results with a scan with a narrow collimation and with a constant scatter correction approach. Scatter correction using primary modulation is possible on a clinical CBCT by compensating for the scanner motion and the tube current modulation. Scatter artifacts could be reduced in the reconstructions of phantom scans and in experimental in vivo data. © 2017 American Association of Physicists in Medicine.

  17. Risk Factors for the Development of Heterotopic Ossification in Seriously Burned Adults: A NIDRR Burn Model System Database Analysis

    PubMed Central

    Levi, Benjamin; Jayakumar, Prakash; Giladi, Avi; Jupiter, Jesse B.; Ring, David C.; Kowalske, Karen; Gibran, Nicole S.; Herndon, David; Schneider, Jeffrey C.; Ryan, Colleen M.

    2015-01-01

    Purpose Heterotopic ossification (HO) is a debilitating complication of burn injury; however, incidence and risk factors are poorly understood. In this study we utilize a multicenter database of adults with burn injuries to identify and analyze clinical factors that predict HO formation. Methods Data from 6 high-volume burn centers, in the Burn Injury Model System Database, were analyzed. Univariate logistic regression models were used for model selection. Cluster-adjusted multivariate logistic regression was then used to evaluate the relationship between clinical and demographic data and the development of HO. Results Of 2,979 patients in the database with information on HO that addressed risk factors for development of HO, 98 (3.5%) developed HO. Of these 98 patients, 97 had arm burns, and 96 had arm grafts. Controlling for age and sex in a multivariate model, patients with >30% total body surface area (TBSA) burn had 11.5x higher odds of developing HO (p<0.001), and those with arm burns that required skin grafting had 96.4x higher odds of developing HO (p=0.04). For each additional time a patient went to the operating room, odds of HO increased 30% (OR 1.32, p<0.001), and each additional ventilator day increase odds 3.5% (OR 1.035, p<0.001). Joint contracture, inhalation injury, and bone exposure did not significantly increase odds of HO. Conclusion Risk factors for HO development include >30% TBSA burn, arm burns, arm grafts, ventilator days, and number of trips to the operating room. Future studies can use these results to identify highest-risk patients to guide deployment of prophylactic and experimental treatments. PMID:26496115

  18. Wideband unbalanced waveguide power dividers and combiners

    DOEpatents

    Halligan, Matthew; McDonald, Jacob Jeremiah; Strassner, II, Bernd H.

    2016-05-17

    The various technologies presented herein relate to waveguide dividers and waveguide combiners for application in radar systems, wireless communications, etc. Waveguide dividers-combiners can be manufactured in accordance with custom dimensions, as well as in accordance with waveguide standards such that the input and output ports are of a defined dimension and have a common impedance. Various embodiments are presented which can incorporate one or more septum(s), one or more pairs of septums, an iris, an input matching region, a notch located on the input waveguide arm, waveguide arms having stepped transformer regions, etc. The various divider configurations presented herein can be utilized in high fractional bandwidth applications, e.g., a fractional bandwidth of about 30%, and RF applications in the Ka frequency band (e.g., 26.5-40 GHz).

  19. An Overview of NASA's Asteroid Redirect Mission (ARM) Concept

    NASA Technical Reports Server (NTRS)

    Abell, P. A.; Mazanek, D. D.; Reeves, D. M.; Chodas, P. W.; Gates, M. M.; Johnson, L. N.; Ticker, R. L.

    2016-01-01

    The National Aeronautics and Space Administration (NASA) is developing the Asteroid Redirect Mission (ARM) as a capability demonstration for future human exploration, including use of high-power solar electric propulsion, which allows for the efficient movement of large masses through deep space. The ARM will also demonstrate the capability to conduct proximity operations with natural space objects and crewed operations beyond the security of quick Earth return. The Asteroid Redirect Robotic Mission (ARRM), currently in formulation, will visit a large near-Earth asteroid (NEA), collect a multi-ton boulder from its surface, conduct a demonstration of a slow push planetary defense technique, and redirect the multi-ton boulder into a stable orbit around the Moon. Once returned to cislunar space in the mid-2020s, astronauts aboard an Orion spacecraft will dock with the robotic vehicle to explore the boulder and return samples to Earth. The ARM is part of NASA's plan to advance technologies, capabilities, and spaceflight experience needed for a human mission to the Martian system in the 2030s. The ARM and subsequent availability of the asteroidal material in cis-lunar space, provide significant opportunities to advance our knowledge of small bodies in the synergistic areas of science, planetary defense, and in-situ resource utilization (ISRU). NASA established the Formulation Assessment and Support Team (FAST), comprised of scientists, engineers, and technologists, which supported ARRM mission requirements formulation, answered specific questions concerning potential target asteroid physical properties, and produced a publically available report. The ARM Investigation Team is being organized to support ARM implementation and execution. NASA is also open to collaboration with its international partners and welcomes further discussions. An overview of the ARM robotic and crewed segments, including mission requirements, NEA targets, and mission operations, and a discussion of potential opportunities for participation with the ARM will be provided.

  20. 32 CFR 552.102 - Requirements for possession and use.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... RESERVATIONS AND NATIONAL CEMETERIES REGULATIONS AFFECTING MILITARY RESERVATIONS Firearms and Weapons § 552.102... within three working days after arrival on the installation, or after obtaining the weapon, except: (1... registered firearms in unit arms rooms. The unit arms room should utilize a standard weapons card and log...

  1. ELECTRIC CONTACT MEANS

    DOEpatents

    Grear, J.W. Jr.

    1959-03-10

    A switch adapted to maintain electrical connections under conditions of vibration or acceleration is described. According to the invention, thc switch includes a rotatable arm carrying a conductive bar arranged to close against two contacts spaced in the same plane. The firm and continuous engagement of the conductive bar with the contacts is acheived by utilizeing a spring located betwenn the vbar and athe a rem frzme and slidable mounting the bar in channel between two arms suspendef from the arm frame.

  2. Control of a Serpentine Robot for Inspection Tasks

    NASA Technical Reports Server (NTRS)

    Colbaugh, R.; Glass, K.; Seraji, H.

    1994-01-01

    This paper presents a simple and robust kinematic control scheme for the JPL serpentine robot system. The proposed strategy is developed using the dampened-least-squares/configuration control methodology, and permits the considerable dexterity of the JPL serpentine robot to be effectively utilized for maneuvering in the congested and uncertain workspaces often encountered in inspection tasks. Computer simulation results are given for the 20 degree-of-freedom (DOF) manipulator system obtained by mounting the twelve DOF serpentine robot at the end-effector of an eight DOF Robotics Research arm/lathe-bed system. These simulations demonstrate that the proposed approach provides an effective method of controlling this complex system.

  3. Airborne RF Measurement System (ARMS) and Analysis of Representative Flight RF Environment

    NASA Technical Reports Server (NTRS)

    Koppen, Sandra V.; Ely, Jay J.; Smith, Laura J.; Jones, Richard A.; Fleck, Vincent J.; Salud, Maria Theresa; Mielnik, John J.

    2007-01-01

    Environmental radio frequency (RF) data over a broad band of frequencies (30 MHz to 1000 MHz) were obtained to evaluate the electromagnetic environment in airspace around several airports. An RF signal measurement system was designed utilizing a spectrum analyzer connected to the NASA Lancair Columbia 300 aircraft's VHF/UHF navigation antenna. This paper presents an overview of the RF measurement system and provides analysis of sample RF signal measurement data. This aircraft installation package and measurement system can be quickly returned to service if needed by future projects requiring measurement of an RF signal environment or exploration of suspected interference situations.

  4. Comparison of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease with Flat-Panel Detectors on Mobile C-arm versus Fixed Systems.

    PubMed

    Guillou, Marie; Maurel, Blandine; Necib, Hatem; Vent, Pierre-Alexandre; Costargent, Alain; Chaillou, Philippe; Gouëffic, Yann; Kaladji, Adrien

    2018-02-01

    Flat-panel detectors on mobile C-arm (MC-arm) systems are currently challenging fixed C-arm (FC-arm) systems used in hybrid operating rooms. MC-arm systems offer an alternative to FC-arm systems in the endovascular treatment of peripheral arterial disease (PAD) but their efficiency has not been evaluated comparatively. Two series of patients undergoing arteriography with intention to treat were included. Each series consisted of 2 nonrandomized groups: an MC-arm group and an FC-arm group. Series 1 evaluated exposure to the patient (MC-arm, n = 113; FC-arm, n = 206) while series 2 evaluated exposure to patients and also health care personnel (MC-arm, n = 24; FC-arm, n = 76). The primary end points for evaluating exposure were air kerma (AK, in mGy) for patients and effective dose for health care personnel (in μSv). After adjustment for the effect of body mass index (analysis of covariance test), AK was found to be lower in the MC-arm group than in the FC-arm group (124.1 ± 142 vs. 173.3 ± 248.7, P = 0.025). There was no difference between the groups with regard to effective dose recorded for senior surgeons or for operating room nurses. However, a higher effective dose was recorded by the MC-arm group external dosimeter for the trainee resident and for nurse anesthetists. In endovascular treatment of lower limb PAD, use of an FC-arm system is associated with more radiation exposure to the patient than an MC-arm system. However, this type of imaging system does not appear to affect exposure to health care personnel. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Overview and Updated Status of the Asteroid Redirect Mission (ARM)

    NASA Astrophysics Data System (ADS)

    Abell, Paul; Mazanek, Daniel D.; Reeves, David M.; Chodas, Paul; Gates, Michele; Johnson, Lindley N.; Ticker, Ronald

    2016-10-01

    The National Aeronautics and Space Administration (NASA) is developing a mission to visit a large near-Earth asteroid (NEA), collect a multi-ton boulder and regolith samples from its surface, demonstrate a planetary defense technique known as the enhanced gravity tractor, and return the asteroidal material to a stable orbit around the Moon. Once returned to cislunar space in the mid-2020s, astronauts will explore the boulder and return to Earth with samples. This Asteroid Redirect Mission (ARM) is part of NASA's plan to advance the technologies, capabilities, and spaceflight experience needed for a human mission to the Martian system in the 2030s and other destinations, as well as provide other broader benefits. Subsequent human and robotic missions to the asteroidal material would also be facilitated by its return to cislunar space. Although ARM is primarily a capability demonstration mission (i.e., technologies and associated operations), there exist significant opportunities to advance our knowledge of small bodies in the synergistic areas of science, planetary defense, asteroidal resources and in-situ resource utilization (ISRU), and capability and technology demonstrations. Current plans are for the robotic mission to be launched in late 2021 with the crewed mission segment conducted using an Orion capsule via a Space Launch System rocket in 2026. In order to maximize the knowledge return from the mission, NASA is providing accommodations for payloads to be carried on the robotic segment of the mission and also organizing an ARM Investigation Team. The Investigation Team will be comprised of scientists, technologists, and other qualified and interested individuals from US industry, government, academia, and international institutions to help plan the implementation and execution of ARM. The presentation will provide a mission overview and the most recent update concerning the robotic and crewed segments of ARM, including the mission requirements, and potential NEA targets. Details about the mission operations for each segment will also be provided along with a discussion of the potential opportunities associated with the mission.

  6. 41 CFR 102-33.440 - Who must report CAS cost and utilization data?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...-MANAGEMENT OF GOVERNMENT AIRCRAFT Reporting Information on Government Aircraft Commercial Aviation Services... agencies, except the Armed Forces and U.S. intelligence agencies, must report CAS cost and utilization data...

  7. Independent Orbiter Assessment (IOA): Analysis of the electrical power distribution and control/remote manipulator system subsystem

    NASA Technical Reports Server (NTRS)

    Robinson, W. W.

    1987-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the Electrical Power Distribution and Control (EPD and C)/Remote Manipulator System (RMS) hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained in the NASA FMEA/CIL documentation. This report documents the results of the independent analysis of the EPD and C/RMS (both port and starboard) hardware. The EPD and C/RMS subsystem hardware provides the electrical power and power control circuitry required to safely deploy, operate, control, and stow or guillotine and jettison two (one port and one starboard) RMSs. The EPD and C/RMS subsystem is subdivided into the four following functional divisions: Remote Manipulator Arm; Manipulator Deploy Control; Manipulator Latch Control; Manipulator Arm Shoulder Jettison; and Retention Arm Jettison. The IOA analysis process utilized available EPD and C/RMS hardware drawings and schematics for defining hardware assemblies, components, and hardware items. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based on the severity of the effect for each failure mode.

  8. KSC-02pd0818

    NASA Image and Video Library

    2002-05-30

    KENNEDY SPACE CENTER, FLA. -- After rollback of the Rotating Service Structure in the early morning hours, Space Shuttle Endeavour sits bathed in light on its Mobile Launcher Platform on Launch Pad 39A. Seen extending to the cockpit area of Endeavour is the orbiter access arm. At the end of the arm is the White Room, an environmental chamber. Below, on either side of Endeavour's tail, are the tail service masts that support fluid, gas and electrical requirements of the orbiter's liquid oxygen and liquid hydrogen aft T-0 umbilicals. STS-111 is the second Utilization Flight to the International Space Station, carrying the Multi-Purpose Logistics Module Leonardo, the Mobile Base System (MBS), and a replacement wrist/roll joint for the Canadarm 2. Also onboard Space Shuttle Endeavour is the Expedition 5 crew who will replace Expedition 4 on board the Station. The MBS will be installed on the Mobile Transporter to complete the Canadian Mobile Servicing System, or MSS. The mechanical arm will then have the capability to "inchworm" from the U.S. Lab Destiny to the MSS and travel along the truss to work sites. Expedition 4 crew members will return to Earth with the STS-111 crew on Endeavour. Launch is scheduled for 7:44 p.m. EDT, May 30, 2002

  9. Bi-stable optical element actuator device

    DOEpatents

    Holdener, Fred R.; Boyd, Robert D.

    2002-01-01

    The present invention is a bistable optical element actuator device utilizing a powered means to move an actuation arm, to which an optical element is attached, between two stable positions. A non-powered means holds the actuation arm in either of the two stable positions. The optical element may be a electromagnetic (EM) radiation or particle source, an instrument, or EM radiation or particle transmissive reflective or absorptive elements. A bearing is used to transfer motion and smoothly transition the actuation arm between the two stable positions.

  10. Autonomous space processor for orbital debris

    NASA Technical Reports Server (NTRS)

    Ramohalli, Kumar; Campbell, David; Brockman, Jeff P.; Carter, Bruce; Donelson, Leslie; John, Lawrence E.; Marine, Micky C.; Rodina, Dan D.

    1989-01-01

    This work continues to develop advanced designs toward the ultimate goal of a GETAWAY SPECIAL to demonstrate economical removal of orbital debris utilizing local resources in orbit. The fundamental technical feasibility was demonstrated last year through theoretical calculations, quantitative computer animation, a solar focal point cutter, a robotic arm design and a subscale model. During this reporting period, several improvements are made in the solar cutter, such as auto track capabilities, better quality reflectors and a more versatile framework. The major advance has been in the design, fabrication and working demonstration of a ROBOTIC ARM that has several degrees of freedom. The functions were specifically tailored for the orbital debris handling. These advances are discussed here. Also a small fraction of the resources were allocated towards research in flame augmentation in SCRAMJETS for the NASP. Here, the fundamental advance was the attainment of Mach numbers up to 0.6 in the flame zone and a vastly improved injection system; the current work is expected to achieve supersonic combustion in the laboratory and an advanced monitoring system.

  11. Research on NC motion controller based on SOPC technology

    NASA Astrophysics Data System (ADS)

    Jiang, Tingbiao; Meng, Biao

    2006-11-01

    With the rapid development of the digitization and informationization, the application of numerical control technology in the manufacturing industry becomes more and more important. However, the conventional numerical control system usually has some shortcomings such as the poor in system openness, character of real-time, cutability and reconfiguration. In order to solve these problems, this paper investigates the development prospect and advantage of the application in numerical control area with system-on-a-Programmable-Chip (SOPC) technology, and puts forward to a research program approach to the NC controller based on SOPC technology. Utilizing the characteristic of SOPC technology, we integrate high density logic device FPGA, memory SRAM, and embedded processor ARM into a single programmable logic device. We also combine the 32-bit RISC processor with high computing capability of the complicated algorithm with the FPGA device with strong motivable reconfiguration logic control ability. With these steps, we can greatly resolve the defect described in above existing numerical control systems. For the concrete implementation method, we use FPGA chip embedded with ARM hard nuclear processor to construct the control core of the motion controller. We also design the peripheral circuit of the controller according to the requirements of actual control functions, transplant real-time operating system into ARM, design the driver of the peripheral assisted chip, develop the application program to control and configuration of FPGA, design IP core of logic algorithm for various NC motion control to configured it into FPGA. The whole control system uses the concept of modular and structured design to develop hardware and software system. Thus the NC motion controller with the advantage of easily tailoring, highly opening, reconfigurable, and expandable can be implemented.

  12. Cost-Effectiveness Analysis of High-Efficiency Hemodiafiltration Versus Low-Flux Hemodialysis Based on the Canadian Arm of the CONTRAST Study.

    PubMed

    Lévesque, Renee; Marcelli, Daniele; Cardinal, Héloïse; Caron, Marie-Line; Grooteman, Muriel P C; Bots, Michiel L; Blankestijn, Peter J; Nubé, Menso J; Grassmann, Aileen; Canaud, Bernard; Gandjour, Afschin

    2015-12-01

    The aim of this study was to assess the cost effectiveness of high-efficiency on-line hemodiafiltration (OL-HDF) compared with low-flux hemodialysis (LF-HD) for patients with end-stage renal disease (ESRD) based on the Canadian (Centre Hospitalier de l'Université de Montréal) arm of a parallel-group randomized controlled trial (RCT), the CONvective TRAnsport STudy. An economic evaluation was conducted for the period of the RCT (74 months). In addition, a Markov state transition model was constructed to simulate costs and health benefits over lifetime. The primary outcome was costs per quality-adjusted life-year (QALY) gained. The analysis had the perspective of the Quebec public healthcare system. A total of 130 patients were randomly allocated to OL-HDF (n = 67) and LF-HD (n = 63). The cost-utility ratio of OL-HDF versus LF-HD was Can$53,270 per QALY gained over lifetime. This ratio was fairly robust in the sensitivity analysis. The cost-utility ratio was lower than that of LF-HD compared with no treatment (immediate death), which was Can$93,008 per QALY gained. High-efficiency OL-HDF can be considered a cost-effective treatment for ESRD in a Canadian setting. Further research is needed to assess cost effectiveness in other settings and healthcare systems.

  13. High precision detector robot arm system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shu, Deming; Chu, Yong

    A method and high precision robot arm system are provided, for example, for X-ray nanodiffraction with an X-ray nanoprobe. The robot arm system includes duo-vertical-stages and a kinematic linkage system. A two-dimensional (2D) vertical plane ultra-precision robot arm supporting an X-ray detector provides positioning and manipulating of the X-ray detector. A vertical support for the 2D vertical plane robot arm includes spaced apart rails respectively engaging a first bearing structure and a second bearing structure carried by the 2D vertical plane robot arm.

  14. Health State Utilities Associated with Glucose Monitoring Devices.

    PubMed

    Matza, Louis S; Stewart, Katie D; Davies, Evan W; Hellmund, Richard; Polonsky, William H; Kerr, David

    2017-03-01

    Glucose monitoring is important for patients with diabetes treated with insulin. Conventional glucose monitoring requires a blood sample, typically obtained by pricking the finger. A new sensor-based system called "flash glucose monitoring" monitors glucose levels with a sensor worn on the arm, without requiring blood samples. To estimate the utility difference between these two glucose monitoring approaches for use in cost-utility models. In time trade-off interviews, general population participants in the United Kingdom (London and Edinburgh) valued health states that were drafted and refined on the basis of literature, clinician input, and a pilot study. The health states had identical descriptions of diabetes and insulin treatment, differing only in glucose monitoring approach. A total of 209 participants completed the interviews (51.7% women; mean age = 42.1 years). Mean utilities were 0.851 ± 0.140 for conventional monitoring and 0.882 ± 0.121 for flash monitoring (significant difference between the mean utilities; t = 8.3; P < 0.0001). Of the 209 participants, 78 (37.3%) had a higher utility for flash monitoring, 2 (1.0%) had a higher utility for conventional monitoring, and 129 (61.7%) had the same utility for both health states. The flash glucose monitoring system was associated with a significantly greater utility than the conventional monitoring system. This difference may be useful in cost-utility models comparing the value of glucose monitoring devices for patients with diabetes. This study adds to the literature on treatment process utilities, suggesting that time trade-off methods may be used to quantify preferences among medical devices. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  15. Cortical Spiking Network Interfaced with Virtual Musculoskeletal Arm and Robotic Arm.

    PubMed

    Dura-Bernal, Salvador; Zhou, Xianlian; Neymotin, Samuel A; Przekwas, Andrzej; Francis, Joseph T; Lytton, William W

    2015-01-01

    Embedding computational models in the physical world is a critical step towards constraining their behavior and building practical applications. Here we aim to drive a realistic musculoskeletal arm model using a biomimetic cortical spiking model, and make a robot arm reproduce the same trajectories in real time. Our cortical model consisted of a 3-layered cortex, composed of several hundred spiking model-neurons, which display physiologically realistic dynamics. We interconnected the cortical model to a two-joint musculoskeletal model of a human arm, with realistic anatomical and biomechanical properties. The virtual arm received muscle excitations from the neuronal model, and fed back proprioceptive information, forming a closed-loop system. The cortical model was trained using spike timing-dependent reinforcement learning to drive the virtual arm in a 2D reaching task. Limb position was used to simultaneously control a robot arm using an improved network interface. Virtual arm muscle activations responded to motoneuron firing rates, with virtual arm muscles lengths encoded via population coding in the proprioceptive population. After training, the virtual arm performed reaching movements which were smoother and more realistic than those obtained using a simplistic arm model. This system provided access to both spiking network properties and to arm biophysical properties, including muscle forces. The use of a musculoskeletal virtual arm and the improved control system allowed the robot arm to perform movements which were smoother than those reported in our previous paper using a simplistic arm. This work provides a novel approach consisting of bidirectionally connecting a cortical model to a realistic virtual arm, and using the system output to drive a robotic arm in real time. Our techniques are applicable to the future development of brain neuroprosthetic control systems, and may enable enhanced brain-machine interfaces with the possibility for finer control of limb prosthetics.

  16. Effects of antenatal care and HIV treatment integration on elements of the PMTCT cascade: Results from the SHAIP cluster-randomized controlled trial in Kenya

    PubMed Central

    Turan, Janet M.; Onono, Maricianah; Steinfeld, Rachel L.; Shade, Starley B.; Owuor, Kevin; Washington, Sierra; Bukusi, Elizabeth A.; Ackers, Marta L.; Kioko, Jackson; Interis, Evelyn C.; Cohen, Craig R.

    2015-01-01

    Background Integrating antenatal care (ANC) and HIV care may improve uptake and retention in services along the prevention of mother-to-child transmission (PMTCT) cascade. The current study aimed to determine if integration of HIV services into ANC settings improves PMTCT service utilization outcomes. Methods ANC clinics in rural Kenya were randomized to integrated (6 clinics, 569 women) or non-integrated (6 clinics, 603 women) services. Intervention clinics provided all HIV services, including highly active antiretroviral therapy (HAART), while control clinics provided PMTCT services but referred women to HIV care clinics within the same facility. PMTCT utilization outcomes among HIV-infected women (maternal HIV care enrollment, HAART initiation, and 3-month infant HIV testing uptake) were compared using generalized estimating equations and Cox regression. Results HIV care enrollment was higher in intervention compared to control clinics (69% versus 36%, Odds Ratio (OR)=3.94, 95% Confidence Interval (CI): 1.14–13.63). Median time to enrollment was significantly shorter among intervention arm women (0 versus 8 days, Hazard Ratio (HR)=2.20, 95% CI: 1.62–3.01). Eligible women in the intervention arm were more likely to initiate HAART (40% versus 17%, OR=3.22, 95% CI: 1.81–5.72). Infant testing was more common in the intervention arm (25% versus 18%), however not statistically different. No significant differences were detected in postnatal service uptake or maternal retention. Conclusions Service integration increased maternal HIV care enrollment and HAART uptake. However, PMTCT utilization outcomes were still suboptimal, and postnatal service utilization remained poor in both study arms. Further improvements in the PMTCT cascade will require additional research and interventions. PMID:25967269

  17. Dual redundant arm system operational quality measures and their applications - Static measures

    NASA Technical Reports Server (NTRS)

    Lee, Sukhan; Kim, Sungbok

    1990-01-01

    The authors present dual-arm system static operational quality measures which quantify the efficiency and capability of a dual-arm system in generating Cartesian velocities and static forces. First, they define and analyze the kinematic interactions between the two arms incurred by the various modes of dual-arm cooperation, such as transport, assembly, and grasping modes of cooperation, and specify the kinematic constraints imposed on individual arms in Cartesian space due to the kinematic interactions. Dual-arm static manipulability is presented. Finally, dual-arm operational quality is scaled by a task-oriented operational quality measure (TOQs) obtained by the comparison between the desired and actual static manipulabilities. TOQs is used in the optimization of dual-arm joint configurations. Simulation results are shown.

  18. Reliability of the Straight-Arm Hang for Testing Muscular Endurance among Children 2 to 5.

    ERIC Educational Resources Information Center

    Gabbard, Carl; And Others

    1979-01-01

    The straight-arm hang as a reliable testing instrument for young children is investigated with results indicating that it is a reliable indicator for four- and five-year-old children. Questionable results may occur if utilized for younger subjects and further investigation is recommended for six-to-nine-year-old subjects. (JD)

  19. Multi-Robot Assembly Strategies and Metrics.

    PubMed

    Marvel, Jeremy A; Bostelman, Roger; Falco, Joe

    2018-02-01

    We present a survey of multi-robot assembly applications and methods and describe trends and general insights into the multi-robot assembly problem for industrial applications. We focus on fixtureless assembly strategies featuring two or more robotic systems. Such robotic systems include industrial robot arms, dexterous robotic hands, and autonomous mobile platforms, such as automated guided vehicles. In this survey, we identify the types of assemblies that are enabled by utilizing multiple robots, the algorithms that synchronize the motions of the robots to complete the assembly operations, and the metrics used to assess the quality and performance of the assemblies.

  20. Non-Line of Sight-Combined Arms (NLOS-CA) Manpower, Personnel and Logistics Impact Analysis (LIA)

    DTIC Science & Technology

    1993-11-15

    total weight and volume to explosive weight have been used. These measure the size of the round relative to the killing power in the round. On this basis...the weapon system is powered up. (3) Alert Time is that time during which radios are operating, but the system is not powered up. For this analysis...TELEPHONE MANUA: SB-22/PT 1S U99185 UTILITY RECEPTACLE I V31211 TELEPHONE SET TA312 26 V•1788 POWER SUPPLY YE8 HYP-571TSEC 2I N32593 SHOP EQUIP AUTO

  1. Multi-Robot Assembly Strategies and Metrics

    PubMed Central

    MARVEL, JEREMY A.; BOSTELMAN, ROGER; FALCO, JOE

    2018-01-01

    We present a survey of multi-robot assembly applications and methods and describe trends and general insights into the multi-robot assembly problem for industrial applications. We focus on fixtureless assembly strategies featuring two or more robotic systems. Such robotic systems include industrial robot arms, dexterous robotic hands, and autonomous mobile platforms, such as automated guided vehicles. In this survey, we identify the types of assemblies that are enabled by utilizing multiple robots, the algorithms that synchronize the motions of the robots to complete the assembly operations, and the metrics used to assess the quality and performance of the assemblies. PMID:29497234

  2. Evolution of robotic arms.

    PubMed

    Moran, Michael E

    2007-01-01

    The foundation of surgical robotics is in the development of the robotic arm. This is a thorough review of the literature on the nature and development of this device with emphasis on surgical applications. We have reviewed the published literature and classified robotic arms by their application: show, industrial application, medical application, etc. There is a definite trend in the manufacture of robotic arms toward more dextrous devices, more degrees-of-freedom, and capabilities beyond the human arm. da Vinci designed the first sophisticated robotic arm in 1495 with four degrees-of-freedom and an analog on-board controller supplying power and programmability. von Kemplen's chess-playing automaton left arm was quite sophisticated. Unimate introduced the first industrial robotic arm in 1961, it has subsequently evolved into the PUMA arm. In 1963 the Rancho arm was designed; Minsky's Tentacle arm appeared in 1968, Scheinman's Stanford arm in 1969, and MIT's Silver arm in 1974. Aird became the first cyborg human with a robotic arm in 1993. In 2000 Miguel Nicolalis redefined possible man-machine capacity in his work on cerebral implantation in owl-monkeys directly interfacing with robotic arms both locally and at a distance. The robotic arm is the end-effector of robotic systems and currently is the hallmark feature of the da Vinci Surgical System making its entrance into surgical application. But, despite the potential advantages of this computer-controlled master-slave system, robotic arms have definite limitations. Ongoing work in robotics has many potential solutions to the drawbacks of current robotic surgical systems.

  3. Primary reaction control system/remote manipulator system interaction with loaded arm. Space shuttle engineering and operations support

    NASA Technical Reports Server (NTRS)

    Taylor, E. C.; Davis, J. D.

    1978-01-01

    A study of the interaction between the orbiter primary reaction control system (PRCS) and the remote manipulator system (RMS) with a loaded arm is documented. This analysis was performed with the Payload Deployment and Retrieval Systems Simulation (PDRSS) program with the passive arm bending option. The passive-arm model simulates the arm as massless elastic links with locked joints. The study was divided into two parts. The first part was the evaluation of the response of the arm to step inputs (i.e. constant jet torques) about each of the orbiter body axes. The second part of the study was the evaluation of the response of the arm to minimum impulse primary RCS jet firings with both single pulse and pulse train inputs.

  4. Integration of the European Arms Industry: An Analysis of Key Variables and Processes in France, Britain, and the Federal Republic of Germany

    DTIC Science & Technology

    1990-03-01

    northern African nations (excluding Egypt, which is considered a Middle East nation) which ranked among the twenty largest Third World arms importers...northern African nation [Ref. 41:p. 193]. Thus, France’s involvement in arms exports to this region was of low economic utility relative to its...policy, the British openly acknow’edge NATO as the keystone of their defense IRef. 76:p. 3]. In the alliance the United Kingdom has a role in the

  5. Two position optical element actuator device

    DOEpatents

    Holdener, Fred R.; Boyd, Robert D.

    2002-01-01

    The present invention is a two position optical element actuator device utilizing a powered means to hold an actuation arm, to which an optical element is attached, in a first position. A non-powered means drives the actuation arm to a second position, when the powered means ceases to receive power. The optical element may be a electromagnetic (EM) radiation or particle source, an instrument, or EM radiation or particle transmissive, reflective or absorptive elements. A bearing is used to transfer motion and smoothly transition the actuation arm from the first to second position.

  6. Birefringence insensitive optical coherence domain reflectometry system

    DOEpatents

    Everett, Matthew J.; Davis, Joseph G.

    2002-01-01

    A birefringence insensitive fiber optic optical coherence domain reflectometry (OCDR) system is provided containing non-polarization maintaining (non-PM) fiber in the sample arm and the reference arm without suffering from signal degradation caused by birefringence. The use of non-PM fiber significantly reduces the cost of the OCDR system and provides a disposable or multiplexed section of the sample arm. The dispersion in the reference arm and sample arm of the OCDR system are matched to achieve high resolution imaging. This system is useful in medical applications or for non-medical in situ probes. The disposable section of non-PM fiber in the sample arm can be conveniently replaced when contaminated by a sample or a patient.

  7. Healthcare resource utilization with ixazomib or placebo plus lenalidomide-dexamethasone in the randomized, double-blind, phase 3 TOURMALINE-MM1 study in relapsed/refractory multiple myeloma.

    PubMed

    Hari, Parameswaran; Lin, Huamao Mark; Zhu, Yanyan; Berg, Deborah; Richardson, Paul G; Moreau, Philippe

    2018-05-29

    The aim of this analysis was to assess healthcare resource utilization in the pivotal phase 3 TOURMALINE-MM1 study of the oral proteasome inhibitor ixazomib or placebo plus lenalidomide and dexamethasone (Rd) in relapsed and/or refractory multiple myeloma (RRMM). In this double-blind, placebo-controlled, randomized study (NCT01564537), 722 patients with RRMM following 1-3 prior lines of therapy received Rd plus ixazomib (ixazomib-Rd; n = 360) or matching placebo (placebo-Rd; n = 362) until disease progression or unacceptable toxicity. Healthcare resource utilization data were captured on Day 1 of each 28-day cycle, every 4 weeks during follow-up for progression-free survival, and every 12 weeks during subsequent follow-up, and included medical encounters (length of stay, inpatient, outpatient, and reason) and number of missing days from work or other activities for patients and caregivers. Exposure-adjusted rates of hospitalization were similar between the ixazomib-Rd and placebo-Rd arms, at 0.530 and 0.564 per patient year (ppy), respectively, as were outpatient visit rates (3.305 and 3.355 ppy). Mean length of hospitalization per patient was 10.0 and 10.8 days, respectively. In both arms, hospitalization and outpatient visit rates were higher in patients with two or three prior lines of treatment (ixazomib-Rd: 0.632 and 3.909 ppy; placebo-Rd: 0.774 and 3.539 ppy) compared with patients with one prior line (ixazomib-Rd: 0.460 and 2.888 ppy; placebo-Rd: 0.436 and 3.243 ppy). Patients and their caregivers who missed any work or other activity missed a median of 7 and 5 days in the ixazomib-Rd arm, respectively, vs 8 and 4 days with placebo-Rd. The study was not powered for a statistical comparison of healthcare resource utilization between treatment arms, nor did it capture costs associated with utilization of the identified healthcare resources. This pre-specified analysis demonstrated that the all-oral triplet regimen of ixazomib added to Rd did not increase healthcare resource utilization compared with placebo-Rd.

  8. An MR-compatible gyroscope-based arm movement tracking system.

    PubMed

    Shirinbayan, S Iman; Rieger, Jochem W

    2017-03-15

    Functional magnetic resonance imaging is well suited to link neural population activation with movement parameters of complex natural arm movements. However, currently existing MR-compatible arm tracking devices are not constructed to measure arm joint movement parameters of unrestricted movements. Therefore, to date most research focuses on simple arm movements or includes very little knowledge about the actual movement kinematics. We developed a low cost gyroscope-based arm movement tracking system (GAMTS) that features MR-compatibility. The system consists of dual-axis analogue gyroscopes that measure rotations of upper and lower arm joints. After MR artifact reduction, the rotation angles of the individual arm joints are calculated and used to animate a realistic arm model that is implemented in the OpenSim platform. The OpenSim platform can then provide the kinematics of any point on the arm model. In order to demonstrate the capabilities of the system, we first assessed the quality of reconstructed wrist movements in a low-noise environment where typical MR-related problems are absent and finally, we validated the reconstruction in the MR environment. The system provides the kinematics of the whole arm when natural unrestricted arm movements are performed inside the MR-scanner. The GAMTS is reliably capable of reconstructing the kinematics of trajectories and the reconstruction error is small in comparison with the movement induced variation of speed, displacement, and rotation. Moreover, the system can be used to probe brain areas for their correlation with movement kinematics. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Measuring Micro-Friction Torque in MEMS Gas Bearings

    PubMed Central

    Fang, Xudong; Liu, Huan

    2016-01-01

    An in situ measurement of micro-friction torque in MEMS gas bearings, which has been a challenging research topic for years, is realized by a system designed in this paper. In the system, a high accuracy micro-force sensor and an electronically-driven table are designed, fabricated and utilized. With appropriate installation of the sensor and bearings on the table, the engine rotor can be driven to rotate with the sensor using a silicon lever beam. One end of the beam is fixed to the shaft of the gas bearing, while the other end is free and in contact with the sensor probe tip. When the sensor begins to rotate with the table, the beam is pushed by the sensor probe to rotate in the same direction. For the beam, the friction torque from the gas bearing is balanced by the torque induced by pushing force from the sensor probe. Thus, the friction torque can be calculated as a product of the pushing force measured by the sensor and the lever arm, which is defined as the distance from the sensor probe tip to the centerline of the bearing. Experimental results demonstrate the feasibility of this system, with a sensitivity of 1.285 mV/μN·m in a range of 0 to 11.76 μN·m when the lever arm is 20 mm long. The measuring range can be modified by varying the length of the lever arm. Thus, this system has wide potential applications in measuring the micro-friction torque of gas bearings in rotating MEMS machines. PMID:27213377

  10. Feasibility study of using a Microsoft Kinect for virtual coaching of wheelchair transfer techniques.

    PubMed

    Hwang, Seonhong; Tsai, Chung-Ying; Koontz, Alicia M

    2017-05-24

    The purpose of this study was to test the concurrent validity and test-retest reliability of the Kinect skeleton tracking algorithm for measurement of trunk, shoulder, and elbow joint angle measurement during a wheelchair transfer task. Eight wheelchair users were recruited for this study. Joint positions were recorded simultaneously by the Kinect and Vicon motion capture systems while subjects transferred from their wheelchairs to a level bench. Shoulder, elbow, and trunk angles recorded with the Kinect system followed a similar trajectory as the angles recorded with the Vicon system with correlation coefficients that are larger than 0.71 on both sides (leading arm and trailing arm). The root mean square errors (RMSEs) ranged from 5.18 to 22.46 for the shoulder, elbow, and trunk angles. The 95% limits of agreement (LOA) for the discrepancy between the two systems exceeded the clinical significant level of 5°. For the trunk, shoulder, and elbow angles, the Kinect had very good relative reliability for the measurement of sagittal, frontal and horizontal trunk angles, as indicated by the high intraclass correlation coefficient (ICC) values (>0.90). Small standard error of the measure (SEM) values, indicating good absolute reliability, were observed for all joints except for the leading arm's shoulder joint. Relatively large minimal detectable changes (MDCs) were observed in all joint angles. The Kinect motion tracking has promising performance levels for some upper limb joints. However, more accurate measurement of the joint angles may be required. Therefore, understanding the limitations in precision and accuracy of Kinect is imperative before utilization of Kinect.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morgansen, K.A.; Pin, F.G.

    A new method for mitigating unexpected impact of a redundant manipulator with an object in its environment is presented. Kinematic constraints are utilized with the recently developed method known as Full Space Parameterization (FSP). System performance criterion and constraints are changed at impact to return the end effector to the point of impact and halt the arm. Since large joint accelerations could occur as the manipulator is halted, joint acceleration bounds are imposed to simulate physical actuator limitations. Simulation results are presented for the case of a simple redundant planar manipulator.

  12. Robust coordinated control of a dual-arm space robot

    NASA Astrophysics Data System (ADS)

    Shi, Lingling; Kayastha, Sharmila; Katupitiya, Jay

    2017-09-01

    Dual-arm space robots are more capable of implementing complex space tasks compared with single arm space robots. However, the dynamic coupling between the arms and the base will have a serious impact on the spacecraft attitude and the hand motion of each arm. Instead of considering one arm as the mission arm and the other as the balance arm, in this work two arms of the space robot perform as mission arms aimed at accomplishing secure capture of a floating target. The paper investigates coordinated control of the base's attitude and the arms' motion in the task space in the presence of system uncertainties. Two types of controllers, i.e. a Sliding Mode Controller (SMC) and a nonlinear Model Predictive Controller (MPC) are verified and compared with a conventional Computed-Torque Controller (CTC) through numerical simulations in terms of control accuracy and system robustness. Both controllers eliminate the need to linearly parameterize the dynamic equations. The MPC has been shown to achieve performance with higher accuracy than CTC and SMC in the absence of system uncertainties under the condition that they consume comparable energy. When the system uncertainties are included, SMC and CTC present advantageous robustness than MPC. Specifically, in a case where system inertia increases, SMC delivers higher accuracy than CTC and costs the least amount of energy.

  13. Cortical Spiking Network Interfaced with Virtual Musculoskeletal Arm and Robotic Arm

    PubMed Central

    Dura-Bernal, Salvador; Zhou, Xianlian; Neymotin, Samuel A.; Przekwas, Andrzej; Francis, Joseph T.; Lytton, William W.

    2015-01-01

    Embedding computational models in the physical world is a critical step towards constraining their behavior and building practical applications. Here we aim to drive a realistic musculoskeletal arm model using a biomimetic cortical spiking model, and make a robot arm reproduce the same trajectories in real time. Our cortical model consisted of a 3-layered cortex, composed of several hundred spiking model-neurons, which display physiologically realistic dynamics. We interconnected the cortical model to a two-joint musculoskeletal model of a human arm, with realistic anatomical and biomechanical properties. The virtual arm received muscle excitations from the neuronal model, and fed back proprioceptive information, forming a closed-loop system. The cortical model was trained using spike timing-dependent reinforcement learning to drive the virtual arm in a 2D reaching task. Limb position was used to simultaneously control a robot arm using an improved network interface. Virtual arm muscle activations responded to motoneuron firing rates, with virtual arm muscles lengths encoded via population coding in the proprioceptive population. After training, the virtual arm performed reaching movements which were smoother and more realistic than those obtained using a simplistic arm model. This system provided access to both spiking network properties and to arm biophysical properties, including muscle forces. The use of a musculoskeletal virtual arm and the improved control system allowed the robot arm to perform movements which were smoother than those reported in our previous paper using a simplistic arm. This work provides a novel approach consisting of bidirectionally connecting a cortical model to a realistic virtual arm, and using the system output to drive a robotic arm in real time. Our techniques are applicable to the future development of brain neuroprosthetic control systems, and may enable enhanced brain-machine interfaces with the possibility for finer control of limb prosthetics. PMID:26635598

  14. Repair of impact damaged utility poles with fiber reinforced polymers (FRP), phase II : [summary].

    DOT National Transportation Integrated Search

    2015-04-01

    The aluminum and steel utility poles which support traffic signals, lighting, or mast-arm signs : are vulnerable to collisions from vehicles because of proximity to roadways. Removing these : poles for repair is costly and time-consuming, and removal...

  15. Design method of ARM based embedded iris recognition system

    NASA Astrophysics Data System (ADS)

    Wang, Yuanbo; He, Yuqing; Hou, Yushi; Liu, Ting

    2008-03-01

    With the advantages of non-invasiveness, uniqueness, stability and low false recognition rate, iris recognition has been successfully applied in many fields. Up to now, most of the iris recognition systems are based on PC. However, a PC is not portable and it needs more power. In this paper, we proposed an embedded iris recognition system based on ARM. Considering the requirements of iris image acquisition and recognition algorithm, we analyzed the design method of the iris image acquisition module, designed the ARM processing module and its peripherals, studied the Linux platform and the recognition algorithm based on this platform, finally actualized the design method of ARM-based iris imaging and recognition system. Experimental results show that the ARM platform we used is fast enough to run the iris recognition algorithm, and the data stream can flow smoothly between the camera and the ARM chip based on the embedded Linux system. It's an effective method of using ARM to actualize portable embedded iris recognition system.

  16. An automatic experimental apparatus to study arm reaching in New World monkeys.

    PubMed

    Yin, Allen; An, Jehi; Lehew, Gary; Lebedev, Mikhail A; Nicolelis, Miguel A L

    2016-05-01

    Several species of the New World monkeys have been used as experimental models in biomedical and neurophysiological research. However, a method for controlled arm reaching tasks has not been developed for these species. We have developed a fully automated, pneumatically driven, portable, and reconfigurable experimental apparatus for arm-reaching tasks suitable for these small primates. We have utilized the apparatus to train two owl monkeys in a visually-cued arm-reaching task. Analysis of neural recordings demonstrates directional tuning of the M1 neurons. Our apparatus allows automated control, freeing the experimenter from manual experiments. The presented apparatus provides a valuable tool for conducting neurophysiological research on New World monkeys. Copyright © 2016. Published by Elsevier B.V.

  17. Autonomous space processor for orbital debris

    NASA Technical Reports Server (NTRS)

    Ramohalli, Kumar; Campbell, David; Marine, Micky; Saad, Mohamad; Bertles, Daniel; Nichols, Dave

    1990-01-01

    Advanced designs are being continued to develop the ultimate goal of a GETAWAY special to demonstrate economical removal of orbital debris utilizing local resources in orbit. The fundamental technical feasibility was demonstrated in 1988 through theoretical calculations, quantitative computer animation, a solar focal point cutter, a robotic arm design and a subcase model. Last year improvements were made to the solar cutter and the robotic arm. Also performed last year was a mission analysis which showed the feasibility of retrieve at least four large (greater than 1500 kg) pieces of debris. Advances made during this reporting period are the incorporation of digital control with the existing placement arm, the development of a new robotic manipulator arm, and the study of debris spin attenuation. These advances are discussed.

  18. Utilization of psychiatric services by female military personnel changes since admission of women to all German Armed Forces military careers.

    PubMed

    Zimmermann, Peter; Ströhle, Andreas; Langner, Franziska; Lanczik, Mario

    2010-07-01

    In 2001, women were admitted to all military careers in the German Armed Forces. This study examines whether the utilization of psychiatric services of female military personnel has changed since then. The central medical database of German military personnel for the years 2000 and 2006 was analyzed. Between 2000 and 2006, the percentage (based on the average totals of male and female military personnel) of consultations of primary care unit surgeons for psychiatric problems increased significantly for both male and female military personnel, this increase being more apparent for women than for men. Stress-related disorders showed the greatest rise. In 2006, as opposed to 2000, the total proportion of both outpatient and inpatient mental health treatment provided to female military personnel was significantly higher than for males, particularly regarding stress-related, affective and personality disorders. Gender-specific aspects should be considered more intensely in preventive and therapeutic psychiatric supply in the German Armed Forces.

  19. A multimedia comprehensive informatics system with decision support tools for a multi-site collaboration research of stroke rehabilitation

    NASA Astrophysics Data System (ADS)

    Wang, Ximing; Documet, Jorge; Garrison, Kathleen A.; Winstein, Carolee J.; Liu, Brent

    2012-02-01

    Stroke is a major cause of adult disability. The Interdisciplinary Comprehensive Arm Rehabilitation Evaluation (I-CARE) clinical trial aims to evaluate a therapy for arm rehabilitation after stroke. A primary outcome measure is correlative analysis between stroke lesion characteristics and standard measures of rehabilitation progress, from data collected at seven research facilities across the country. Sharing and communication of brain imaging and behavioral data is thus a challenge for collaboration. A solution is proposed as a web-based system with tools supporting imaging and informatics related data. In this system, users may upload anonymized brain images through a secure internet connection and the system will sort the imaging data for storage in a centralized database. Users may utilize an annotation tool to mark up images. In addition to imaging informatics, electronic data forms, for example, clinical data forms, are also integrated. Clinical information is processed and stored in the database to enable future data mining related development. Tele-consultation is facilitated through the development of a thin-client image viewing application. For convenience, the system supports access through desktop PC, laptops, and iPAD. Thus, clinicians may enter data directly into the system via iPAD while working with participants in the study. Overall, this comprehensive imaging informatics system enables users to collect, organize and analyze stroke cases efficiently.

  20. Towards automatic Markov reliability modeling of computer architectures

    NASA Technical Reports Server (NTRS)

    Liceaga, C. A.; Siewiorek, D. P.

    1986-01-01

    The analysis and evaluation of reliability measures using time-varying Markov models is required for Processor-Memory-Switch (PMS) structures that have competing processes such as standby redundancy and repair, or renewal processes such as transient or intermittent faults. The task of generating these models is tedious and prone to human error due to the large number of states and transitions involved in any reasonable system. Therefore model formulation is a major analysis bottleneck, and model verification is a major validation problem. The general unfamiliarity of computer architects with Markov modeling techniques further increases the necessity of automating the model formulation. This paper presents an overview of the Automated Reliability Modeling (ARM) program, under development at NASA Langley Research Center. ARM will accept as input a description of the PMS interconnection graph, the behavior of the PMS components, the fault-tolerant strategies, and the operational requirements. The output of ARM will be the reliability of availability Markov model formulated for direct use by evaluation programs. The advantages of such an approach are (a) utility to a large class of users, not necessarily expert in reliability analysis, and (b) a lower probability of human error in the computation.

  1. Integrated optical gyroscopes offering low cost, small size and vibration immunity

    NASA Astrophysics Data System (ADS)

    Monovoukas, Christos; Swiecki, Andrew; Maseeh, Fariborz

    2000-03-01

    IntelliSense has developed an integrated optic gyro technology that provides the sensitivity of fiber optic gyros while utilizing batch microfabrication techniques to achieve the low cost of mechanical MEMS gyros. The base technology consists of an optical resonating waveguide chip, sensor electronics and an optical bench. The sensing element is based on an integrated optic waveguide chip in which counter-propagating optical fields are used to sense rotation in the plane of the waveguide through the Sagnac effect. It is powered by a semiconductor laser light source, which is coupled into a waveguide and split into two waveguide arms. Both signals are probed through the out coupled light at each waveguide arm, and rate information is derived from the difference in phase between these two signals. Measuring angular rotation is important for proper operation of a variety of systems such as: missile guidance systems, satellites, energy exploration, camera stabilization, robotics positioning, platform stabilization and space craft guidance to mention a few. This technology overcomes the limitations that previous commercially available gyros for this purpose have had including limitations in size, sensitivity, durability, and premium price.

  2. Structural insights into the inactivation of CRISPR-Cas systems by diverse anti-CRISPR proteins.

    PubMed

    Zhu, Yuwei; Zhang, Fan; Huang, Zhiwei

    2018-03-19

    A molecular arms race is progressively being unveiled between prokaryotes and viruses. Prokaryotes utilize CRISPR-mediated adaptive immune systems to kill the invading phages and mobile genetic elements, and in turn, the viruses evolve diverse anti-CRISPR proteins to fight back. The structures of several anti-CRISPR proteins have now been reported, and here we discuss their structural features, with a particular emphasis on topology, to discover their similarities and differences. We summarize the CRISPR-Cas inhibition mechanisms of these anti-CRISPR proteins in their structural context. Considering anti-CRISPRs in this way will provide important clues for studying their origin and evolution.

  3. Human-like Compliance for Dexterous Robot Hands

    NASA Technical Reports Server (NTRS)

    Jau, Bruno M.

    1995-01-01

    This paper describes the Active Electromechanical Compliance (AEC) system that was developed for the Jau-JPL anthropomorphic robot. The AEC system imitates the functionality of the human muscle's secondary function, which is to control the joint's stiffness: AEC is implemented through servo controlling the joint drive train's stiffness. The control strategy, controlling compliant joints in teleoperation, is described. It enables automatic hybrid position and force control through utilizing sensory feedback from joint and compliance sensors. This compliant control strategy is adaptable for autonomous robot control as well. Active compliance enables dual arm manipulations, human-like soft grasping by the robot hand, and opens the way to many new robotics applications.

  4. My Team of Care Study: A Pilot Randomized Controlled Trial of a Web-Based Communication Tool for Collaborative Care in Patients With Advanced Cancer.

    PubMed

    Voruganti, Teja; Grunfeld, Eva; Jamieson, Trevor; Kurahashi, Allison M; Lokuge, Bhadra; Krzyzanowska, Monika K; Mamdani, Muhammad; Moineddin, Rahim; Husain, Amna

    2017-07-18

    The management of patients with complex care needs requires the expertise of health care providers from multiple settings and specialties. As such, there is a need for cross-setting, cross-disciplinary solutions that address deficits in communication and continuity of care. We have developed a Web-based tool for clinical collaboration, called Loop, which assembles the patient and care team in a virtual space for the purpose of facilitating communication around care management. The objectives of this pilot study were to evaluate the feasibility of integrating a tool like Loop into current care practices and to capture preliminary measures of the effect of Loop on continuity of care, quality of care, symptom distress, and health care utilization. We conducted an open-label pilot cluster randomized controlled trial allocating patients with advanced cancer (defined as stage III or IV disease) with ≥3 months prognosis, their participating health care team and caregivers to receive either the Loop intervention or usual care. Outcome data were collected from patients on a monthly basis for 3 months. Trial feasibility was measured with rate of uptake, as well as recruitment and system usage. The Picker Continuity of Care subscale, Palliative care Outcomes Scale, Edmonton Symptom Assessment Scale, and Ambulatory and Home Care Record were patient self-reported measures of continuity of care, quality of care, symptom distress, and health services utilization, respectively. We conducted a content analysis of messages posted on Loop to understand how the system was used. Nineteen physicians (oncologists or palliative care physicians) were randomized to the intervention or control arms. One hundred twenty-seven of their patients with advanced cancer were approached and 48 patients enrolled. Of 24 patients in the intervention arm, 20 (83.3%) registered onto Loop. In the intervention and control arms, 12 and 11 patients completed three months of follow-up, respectively. A mean of 1.2 (range: 0 to 4) additional healthcare providers with an average total of 3 healthcare providers participated per team. An unadjusted between-arm increase of +11.4 was observed on the Picker scale in favor of the intervention arm. Other measures showed negligible changes. Loop was primarily used for medical care management, symptom reporting, and appointment coordination. The results of this study show that implementation of Loop was feasible. It provides useful information for planning future studies further examining effectiveness and team collaboration. Numerically higher scores were observed for the Loop arm relative to the control arm with respect to continuity of care. Future work is required to understand the incentives and barriers to participation so that the implementation of tools like Loop can be optimized. ClinicalTrials.gov NCT02372994; https://clinicaltrials.gov/ct2/show/NCT02372994 (Archived by WebCite at http://www.webcitation.org/6r00L4Skb). ©Teja Voruganti, Eva Grunfeld, Trevor Jamieson, Allison M Kurahashi, Bhadra Lokuge, Monika K Krzyzanowska, Muhammad Mamdani, Rahim Moineddin, Amna Husain. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 18.07.2017.

  5. Interchangeable end effector tools utilized on the PFMA

    NASA Technical Reports Server (NTRS)

    Cody, Joe; Carroll, John; Crow, George; Gierow, Paul; Littles, Jay; Maness, Michael; Morrison, Jim

    1992-01-01

    An instrumented task board, used for measuring forces applied by the Protoflight Manipulator Arm (PFMA) to the task board, was fabricated and delivered to Marshall Space Flight Center. SRS Technologies phased out the existing IBM compatible data acquisition system, used with a instrumented task board, and integrated the force measuring electronic hardware in with the Macintosh II data acquisition system. The purpose of this change was to acquire all data with the same time tag, allowing easier and more accurate data reduction in addition to real-time graphics. A three-dimensional optical position sensing system for determining the location of the PFMA's end effect or in reference to the center of the instrumented task board was also designed and delivered under. An improved task board was fabricated which included an improved instrumented beam design. The modified design of the task board improved the force/torque measurement system by increasing the sensitivity, reliability, load range and ease of maintenance. A calibration panel for the optical position system was also designed and fabricated. The calibration method developed for the position sensors enhanced the performance of the sensors as well as simplified the installation and calibration procedures required. The modifications made under this effort expanded the capabilities of the task board system. The system developed determines the arm's position relative to the task board and measures the signals to the joints resulting from the operator's control signals in addition to the task board forces. The software and hardware required to calculate and record the position of the PFMA during the performance of tasks with the instrumented task board were defined, designed and delivered to MSFC. PFMA joint input signals can be measured from a breakout box to evaluate the sensitivity or response of the arm operation to control commands. The data processing system provides the capability for post processing of time-history graphics and plots of the PFMA positions, the operator's actions, and the PFMA servo reactions in addition to realtime force and position sensor data presentation.

  6. Interchangeable end effector tools utilized on the PFMA

    NASA Astrophysics Data System (ADS)

    Cody, Joe; Carroll, John; Crow, George; Gierow, Paul; Littles, Jay; Maness, Michael; Morrison, Jim

    1992-02-01

    An instrumented task board, used for measuring forces applied by the Protoflight Manipulator Arm (PFMA) to the task board, was fabricated and delivered to Marshall Space Flight Center. SRS Technologies phased out the existing IBM compatible data acquisition system, used with a instrumented task board, and integrated the force measuring electronic hardware in with the Macintosh II data acquisition system. The purpose of this change was to acquire all data with the same time tag, allowing easier and more accurate data reduction in addition to real-time graphics. A three-dimensional optical position sensing system for determining the location of the PFMA's end effect or in reference to the center of the instrumented task board was also designed and delivered under. An improved task board was fabricated which included an improved instrumented beam design. The modified design of the task board improved the force/torque measurement system by increasing the sensitivity, reliability, load range and ease of maintenance. A calibration panel for the optical position system was also designed and fabricated. The calibration method developed for the position sensors enhanced the performance of the sensors as well as simplified the installation and calibration procedures required. The modifications made under this effort expanded the capabilities of the task board system. The system developed determines the arm's position relative to the task board and measures the signals to the joints resulting from the operator's control signals in addition to the task board forces. The software and hardware required to calculate and record the position of the PFMA during the performance of tasks with the instrumented task board were defined, designed and delivered to MSFC. PFMA joint input signals can be measured from a breakout box to evaluate the sensitivity or response of the arm operation to control commands. The data processing system provides the capability for post processing of time-history graphics and plots of the PFMA positions, the operator's actions, and the PFMA servo reactions in addition to realtime force and position sensor data presentation.

  7. Dual-balanced detection scheme with optical hard-limiters in an optical code division multiple access system

    NASA Astrophysics Data System (ADS)

    Liu, Maw-Yang; Hsu, Yi-Kai

    2017-03-01

    Three-arm dual-balanced detection scheme is studied in an optical code division multiple access system. As the MAI and beat noise are the main deleterious source of system performance, we utilize optical hard-limiters to alleviate such channel impairment. In addition, once the channel condition is improved effectively, the proposed two-dimensional error correction code can remarkably enhance the system performance. In our proposed scheme, the optimal thresholds of optical hard-limiters and decision circuitry are fixed, and they will not change with other system parameters. Our proposed scheme can accommodate a large number of users simultaneously and is suitable for burst traffic with asynchronous transmission. Therefore, it is highly recommended as the platform for broadband optical access network.

  8. System For Research On Multiple-Arm Robots

    NASA Technical Reports Server (NTRS)

    Backes, Paul G.; Hayati, Samad; Tso, Kam S.; Hayward, Vincent

    1991-01-01

    Kali system of computer programs and equipment provides environment for research on distributed programming and distributed control of coordinated-multiple-arm robots. Suitable for telerobotics research involving sensing and execution of low level tasks. Software and configuration of hardware designed flexible so system modified easily to test various concepts in control and programming of robots, including multiple-arm control, redundant-arm control, shared control, traded control, force control, force/position hybrid control, design and integration of sensors, teleoperation, task-space description and control, methods of adaptive control, control of flexible arms, and human factors.

  9. 105KE Basin Area Radiation Monitor System (ARMS) Acceptance Test Procedure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    KINKEL, C.C.

    1999-12-14

    This procedure is intended for the Area Radiation Monitoring System, ARMS, that is replacing the existing Programmable Input-Output Processing System, PIOPS, radiation monitoring system in the 105KE basin. The new system will be referred to as the 105KE ARMS, 105KE Area Radiation Monitoring System. This ATP will ensure calibration integrity of the 105KE radiation detector loops. Also, this ATP will test and document the display, printing, alarm output, alarm acknowledgement, upscale check, and security functions. This ATP test is to be performed after completion of the 105KE ARMS installation. The alarm outputs of the 105KE ARMS will be connected tomore » the basin detector alarms, basin annunciator system, and security Alarm Monitoring System, AMS, located in the 200 area Central Alarm Station (CAS).« less

  10. Design of the arm-wrestling robot's force acquisition system based on Qt

    NASA Astrophysics Data System (ADS)

    Huo, Zhixiang; Chen, Feng; Wang, Yongtao

    2017-03-01

    As a collection of entertainment and medical rehabilitation in a robot, the research on the arm-wrestling robot is of great significance. In order to achieve the collection of the arm-wrestling robot's force signals, the design and implementation of arm-wrestling robot's force acquisition system is introduced in this paper. The system is based on MP4221 data acquisition card and is programmed by Qt. It runs successfully in collecting the analog signals on PC. The interface of the system is simple and the real-time performance is good. The result of the test shows the feasibility in arm-wrestling robot.

  11. Principles of Jet Engine Operation

    DTIC Science & Technology

    1978-05-01

    and discharged from the rotor radially (perpendicular-to the axis .,f rotation). In-contrast, the axial flow compressor both admits and dis- charges... TurbofanS for most contemporary turbojet powered aircraft applications, the axial flow compressor is utilized. The remainder of the discussion will...usually installed on several radial arms which are evenly spaced around the compressor face. The spacing of the probes on the arms is such that they are

  12. Early Program Development

    NASA Image and Video Library

    1970-01-01

    Managed by Marshall Space Flight Center, the Space Tug concept was intended to be a reusable multipurpose space vehicle designed to transport payloads to different orbital inclinations. Utilizing mission-specific combinations of its three primary modules (crew, propulsion, and cargo) and a variety of supplementary kits, the Space Tug would have been capable of numerous space applications. This 1970 illustration depicts the primary modules of the Space Tug system along with some of the supplementary kits: lunar landing legs, extendable support arms, astrionics, and the satellite probe. The Space Tug program was cancelled and did not become a reality.

  13. Coordination of multiple robot arms

    NASA Technical Reports Server (NTRS)

    Barker, L. K.; Soloway, D.

    1987-01-01

    Kinematic resolved-rate control from one robot arm is extended to the coordinated control of multiple robot arms in the movement of an object. The structure supports the general movement of one axis system (moving reference frame) with respect to another axis system (control reference frame) by one or more robot arms. The grippers of the robot arms do not have to be parallel or at any pre-disposed positions on the object. For multiarm control, the operator chooses the same moving and control reference frames for each of the robot arms. Consequently, each arm then moves as though it were carrying out the commanded motions by itself.

  14. Conceptual design of a mobile remote manipulator system

    NASA Technical Reports Server (NTRS)

    Bush, H. G.; Mikulas, M. M., Jr.; Wallsom, R. E.; Jensen, J. K.

    1984-01-01

    A mobile remote manipulator system has been identified as a necessary device for space station. A conceptual design for an MRMS is presented which features (1) tracks on the MRMS and guide pins only on the truss structure, (2) a push/pull drive mechanism which rotates to permit movement in four directions, and (3) spacecrane and mobile foot restraint manipulators (or arms). Operational and design features of the MRMS elements are described and illustrated. Concepts are also presented which permit rotating the operational plane of the MRMS through 90 deg. Such a system has been found to have great utility for initial space station construction, maintenance and repair, and to provide a construction capability for future station growth or large spacecraft assembly and/or servicing.

  15. Dual redundant arm system operational quality measures and their applications - Dynamic measures

    NASA Technical Reports Server (NTRS)

    Lee, Sukhan; Kim, Sungbok

    1990-01-01

    Dual-arm dynamic operation quality measures are presented which quantify the efficiency and capability of generating Cartesian accelerations by two cooperative arms based on the analysis of dual-arm dynamic interactions. Dual-arm dynamic manipulability is defined as the efficiency of generating Cartesian accelerations under the dynamic and kinematic interactions between individual arms and an object under manipulation. The analysis of dual-arm dynamic interactions is based on the so-called Cartesian space agent model of an arm, which represents an individual arm as a force source acting upon a point mass with the effective Cartesian space arm dynamics and an environment or an object under manipulation. The Cartesian space agent model of an arm makes it possible to derive the dynamic and kinematic constraints involved in the transport, assembly and grasping modes of dual-arm cooperation. A task-oriented operational quality measure, (TOQd) is defined by evaluating dual-arm dynamic manipulability in terms of given task requirements. TOQd is used in dual-arm joint configuration optimization. Simulation results are shown. A complete set of forward dynamic equations for a dual-arm system is derived, and dual-arm dynamic operational quality measures for various modes of dual-arm cooperation allowing sliding contacts are established.

  16. Robot trajectory tracking with self-tuning predicted control

    NASA Technical Reports Server (NTRS)

    Cui, Xianzhong; Shin, Kang G.

    1988-01-01

    A controller that combines self-tuning prediction and control is proposed for robot trajectory tracking. The controller has two feedback loops: one is used to minimize the prediction error, and the other is designed to make the system output track the set point input. Because the velocity and position along the desired trajectory are given and the future output of the system is predictable, a feedforward loop can be designed for robot trajectory tracking with self-tuning predicted control (STPC). Parameters are estimated online to account for the model uncertainty and the time-varying property of the system. The authors describe the principle of STPC, analyze the system performance, and discuss the simplification of the robot dynamic equations. To demonstrate its utility and power, the controller is simulated for a Stanford arm.

  17. Does the type of somatosensory information from the contralateral finger touch affect grip force control while lifting an object?

    PubMed

    Chen, Bing; Aruin, Alexander S

    2013-11-27

    The magnitude of grip force used to lift and transport a hand-held object is decreased if a light finger touch from the contralateral arm is provided to the wrist of the target arm. We investigated whether the type of contralateral arm sensory input that became available with the finger touch to the target arm affects the way grip force is reduced. Nine healthy subjects performed the same task of lifting and transporting an instrumented object with no involvement of the contralateral arm and when an index finger touch of the contralateral arm was provided to the wrist, elbow, and shoulder. Touching the wrist and elbow involved movements of the contralateral arm; no movements were produced while touching the shoulder. Grip force was reduced by approximately the same amount in all conditions with the finger touch compared to the no touch condition. This suggests that information from the muscle and joint receptors of the contralateral arm is used in control of grip force when a finger touch is provided to the wrist and elbow, and cutaneous information is utilized when lifting an object while touching the shoulder. The results of the study provide additional evidence to support the use of a second arm in the performance of activities of daily living and stress the importance of future studies investigating contralateral arm sensory input in grip force control. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  18. A Kinematic Calibration Process for Flight Robotic Arms

    NASA Technical Reports Server (NTRS)

    Collins, Curtis L.; Robinson, Matthew L.

    2013-01-01

    The Mars Science Laboratory (MSL) robotic arm is ten times more massive than any Mars robotic arm before it, yet with similar accuracy and repeatability positioning requirements. In order to assess and validate these requirements, a higher-fidelity model and calibration processes were needed. Kinematic calibration of robotic arms is a common and necessary process to ensure good positioning performance. Most methodologies assume a rigid arm, high-accuracy data collection, and some kind of optimization of kinematic parameters. A new detailed kinematic and deflection model of the MSL robotic arm was formulated in the design phase and used to update the initial positioning and orientation accuracy and repeatability requirements. This model included a higher-fidelity link stiffness matrix representation, as well as a link level thermal expansion model. In addition, it included an actuator backlash model. Analytical results highlighted the sensitivity of the arm accuracy to its joint initialization methodology. Because of this, a new technique for initializing the arm joint encoders through hardstop calibration was developed. This involved selecting arm configurations to use in Earth-based hardstop calibration that had corresponding configurations on Mars with the same joint torque to ensure repeatability in the different gravity environment. The process used to collect calibration data for the arm included the use of multiple weight stand-in turrets with enough metrology targets to reconstruct the full six-degree-of-freedom location of the rover and tool frames. The follow-on data processing of the metrology data utilized a standard differential formulation and linear parameter optimization technique.

  19. Patterns of motor activity in the isolated nerve cord of the octopus arm.

    PubMed

    Gutfreund, Yoram; Matzner, Henry; Flash, Tamar; Hochner, Binyamin

    2006-12-01

    The extremely flexible octopus arm provides a unique opportunity for studying movement control in a highly redundant motor system. We describe a novel preparation that allows analysis of the peripheral nervous system of the octopus arm and its interaction with the muscular and mechanosensory elements of the arm's intrinsic muscular system. First we examined the synaptic responses in muscle fibers to identify the motor pathways from the axial nerve cord of the arm to the surrounding musculature. We show that the motor axons project to the muscles via nerve roots originating laterally from the arm nerve cord. The motor field of each nerve is limited to the region where the nerve enters the arm musculature. The same roots also carry afferent mechanosensory information from the intrinsic muscle to the axial nerve cord. Next, we characterized the pattern of activity generated in the dorsal roots by electrically stimulating the axial nerve cord. The evoked activity, although far reaching and long lasting, cannot alone account for the arm extension movements generated by similar electrical stimulation. The mismatch between patterns of activity in the isolated cord and in an intact arm may stem from the involvement of mechanosensory feedback in natural arm extension.

  20. Estimating mean QALYs in trial-based cost-effectiveness analysis: the importance of controlling for baseline utility.

    PubMed

    Manca, Andrea; Hawkins, Neil; Sculpher, Mark J

    2005-05-01

    In trial-based cost-effectiveness analysis baseline mean utility values are invariably imbalanced between treatment arms. A patient's baseline utility is likely to be highly correlated with their quality-adjusted life-years (QALYs) over the follow-up period, not least because it typically contributes to the QALY calculation. Therefore, imbalance in baseline utility needs to be accounted for in the estimation of mean differential QALYs, and failure to control for this imbalance can result in a misleading incremental cost-effectiveness ratio. This paper discusses the approaches that have been used in the cost-effectiveness literature to estimate absolute and differential mean QALYs alongside randomised trials, and illustrates the implications of baseline mean utility imbalance for QALY calculation. Using data from a recently conducted trial-based cost-effectiveness study and a micro-simulation exercise, the relative performance of alternative estimators is compared, showing that widely used methods to calculate differential QALYs provide incorrect results in the presence of baseline mean utility imbalance regardless of whether these differences are formally statistically significant. It is demonstrated that multiple regression methods can be usefully applied to generate appropriate estimates of differential mean QALYs and an associated measure of sampling variability, while controlling for differences in baseline mean utility between treatment arms in the trial. Copyright 2004 John Wiley & Sons, Ltd

  1. Robotic system for retractable teleoperated arm within enclosed shell with capability of operating within a confined space

    DOEpatents

    Randolph, John David; Lloyd, Peter Downes; Love, Lonnie Joe; Kwon, Dong Soo; Blank, James Allen; Davis, Hurley Thomas

    2001-01-01

    An apparatus for performing a task in a confined space having an access port. The apparatus comprise: a confinement box securable to the access port of the confined space; a shell extending from the confinement box; a teleoperated arm movable between a retracted position, in which the teleoperated arm is disposed within the shell, and a deployed position, in which the teleoperated arm extends through the access port and into the confined space to perform the task; and a control system for commanding the teleoperated arm. The arm links and joint connectors of the teleoperated arm assembly are the conduits for the process

  2. Therapeutic synergism in the treatment of post-stroke arm paresis utilizing botulinum toxin, robotic therapy, and constraint-induced movement therapy.

    PubMed

    Takebayashi, Takashi; Amano, Satoru; Hanada, Keisuke; Umeji, Atsushi; Takahashi, Kayoko; Koyama, Tetsuo; Domen, Kazuhisa

    2014-11-01

    Botulinum toxin type A (BtxA) injection, constraint-induced movement therapy (CIMT), and robotic therapy (RT) each represent promising approaches to enhance arm motor recovery after stroke. To provide more effective treatment for a 50-year-old man with severe left spastic hemiparesis, we attempted to facilitate CIMT with adaptive approaches to extend the wrist and fingers using RT for 10 consecutive weeks after BtxA injection. This combined treatment resulted in substantial improvements in arm function and the amount of arm use in activities of daily living, and may be effective for stroke patients with severe arm paresis. However, we were unable to sufficiently prove the efficacy of combined treatment based only on a single case. To fully elucidate the efficacy of the combined approach for patients with severe hemiparesis after stroke, future studies of a larger number of patients are needed. Copyright © 2014 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  3. Fabrication of 14 different RNA nanoparticles for specific tumor targeting without accumulation in normal organs

    PubMed Central

    Shu, Yi; Haque, Farzin; Shu, Dan; Li, Wei; Zhu, Zhenqi; Kotb, Malak; Lyubchenko, Yuri; Guo, Peixuan

    2013-01-01

    Due to structural flexibility, RNase sensitivity, and serum instability, RNA nanoparticles with concrete shapes for in vivo application remain challenging to construct. Here we report the construction of 14 RNA nanoparticles with solid shapes for targeting cancers specifically. These RNA nanoparticles were resistant to RNase degradation, stable in serum for >36 h, and stable in vivo after systemic injection. By applying RNA nanotechnology and exemplifying with these 14 RNA nanoparticles, we have established the technology and developed “toolkits” utilizing a variety of principles to construct RNA architectures with diverse shapes and angles. The structure elements of phi29 motor pRNA were utilized for fabrication of dimers, twins, trimers, triplets, tetramers, quadruplets, pentamers, hexamers, heptamers, and other higher-order oligomers, as well as branched diverse architectures via hand-in-hand, foot-to-foot, and arm-on-arm interactions. These novel RNA nanostructures harbor resourceful functionalities for numerous applications in nanotechnology and medicine. It was found that all incorporated functional modules, such as siRNA, ribozymes, aptamers, and other functionalities, folded correctly and functioned independently within the nanoparticles. The incorporation of all functionalities was achieved prior, but not subsequent, to the assembly of the RNA nanoparticles, thus ensuring the production of homogeneous therapeutic nanoparticles. More importantly, upon systemic injection, these RNA nanoparticles targeted cancer exclusively in vivo without accumulation in normal organs and tissues. These findings open a new territory for cancer targeting and treatment. The versatility and diversity in structure and function derived from one biological RNA molecule implies immense potential concealed within the RNA nanotechnology field. PMID:23604636

  4. STS123-S-001

    NASA Image and Video Library

    2007-09-30

    STS123-S-001 (Oct. 2007) --- STS-123 continues assembly of the International Space Station (ISS). The primary mission objectives include rotating an expedition crew member and installing both the first component of the Japanese Experimental Module (the Experimental Logistics Module - Pressurized Section (ELM-PS)) and the Canadian Special Purpose Dexterous Manipulator (SPDM). In addition, STS-123 will deliver various spare ISS components and leave behind the sensor boom used for inspecting the shuttle's thermal protection system. A follow-on mission to ISS will utilize and then return home with this sensor boom. A total of four spacewalks are planned to accomplish these tasks. The mission will also require the use of both the shuttle and ISS robotic arms. STS-123 will utilize the Station-Shuttle Power Transfer System to extend the docked portion of the mission to eleven days, with a total planned duration of 15 days. The crew patch depicts the space shuttle in orbit with the crew names trailing behind. STS-123's major additions to ISS (the ELM-PS installation with the shuttle robotic arm and the fully constructed SPDM) are both illustrated. The ISS is shown in the configuration that the STS-123 crew will encounter when they arrive. The NASA insignia design for space shuttle flights is reserved for use by the astronauts and for other official use as the NASA Administrator may authorize. Public availability has been approved only in the forms of illustrations by the various news media. When and if there is any change in this policy, which is not anticipated, the change will be publicly announced. Photo credit: NASA

  5. KSC-08pd0363

    NASA Image and Video Library

    2007-10-01

    JOHNSON SPACE CENTER, HOUSTON -- STS123-S-001-- STS-123 continues assembly of the International Space Station (ISS). The primary mission objectives include rotating an expedition crew member and installing both the first component of the Japanese Experimental Module (the Experimental Logistics Module - Pressurized Section [ELM-PS]) and the Canadian Special Purpose Dexterous Manipulator (SPDM). In addition, STS-123 will deliver various spare ISS components and leave behind the sensor boom used for inspecting the shuttle's thermal protection system. A follow-on mission to ISS will utilize and then return home with this sensor boom. A total of four spacewalks are planned to accomplish these tasks. The mission will also require the use of both the shuttle and ISS robotic arms. STS-123 will utilize the Station-Shuttle Power Transfer System to extend the docked portion of the mission to 11 days, with a total planned duration of 15 days. The crew patch depicts the space shuttle in orbit with the crew names trailing behind. STS-123's major additions to ISS (the ELM-PS installation with the shuttle robotic arm and the fully constructed SPDM) are both illustrated. The ISS is shown in the configuration that the STS-123 crew will encounter when they arrive. The NASA insignia design for shuttle flights is reserved for use by the astronauts and for other official use as the NASA Administrator may authorize. Public availability has been approved only in the form of illustrations by the various news media. When and if there is any change in this policy, which is not anticipated, it will be publicly announced.

  6. Optically controlled welding system

    NASA Technical Reports Server (NTRS)

    Gordon, Stephen S. (Inventor)

    1988-01-01

    An optically controlled welding system wherein a welding torch having through-the-torch viewing capabilities is provided with an optical beam splitter to create a transmitted view and a reflective view of a welding operation. These views are converted to digital signals which are then processed and utilized by a computerized robotic welder to make the welding torch responsive thereto. Other features include an actively cooled electrode holder which minimizes a blocked portion of the view by virtue of being constructed of a single spoke or arm, and a weld pool contour detector comprising a laser beam directed onto the weld pool with the position of specular radiation reflected therefrom, being characteristic of a penetrated or unpenetrated condition of the weld pool.

  7. LIFELAX - diet and LIFEstyle versus LAXatives in the management of chronic constipation in older people: randomised controlled trial.

    PubMed

    Speed, C; Heaven, B; Adamson, A; Bond, J; Corbett, S; Lake, A A; May, C; Vanoli, A; McMeekin, P; Moynihan, P; Rubin, G; Steen, I N; McColl, E

    2010-11-01

    To investigate the clinical effectiveness and cost-effectiveness of laxatives versus dietary and lifestyle advice, and standardised versus personalised dietary and lifestyle advice. A prospective, pragmatic, three-armed cluster randomised trial with an economic evaluation. General practices in England and Scotland, UK. People aged ≥ 55 years with chronic constipation, living in private households. Participants were identified as those who had been prescribed laxatives three or more times in the previous 12 months, or with a recorded diagnosis of chronic functional constipation. Prescription of laxatives, with class of laxative and dose at the discretion of the GP and patient (standard care control arm); standardised, non-personalised dietary and lifestyle advice; and, personalised dietary and lifestyle advice, with reinforcement. The primary outcome was the constipation-specific Patient Assessment of Constipation-Symptoms (PAC-SYM)/Patient Assessment of Constipation-Quality of Life (PAC-QOL). The trial planned to recruit and retain 1425 patients from 57 practices (19 per arm); however, only 154 patients were recruited from 19 practices. Due to these low recruitment rates it was not possible to report the conventional trial findings. Baseline characteristics of the sample from data gathered from both postal self-completion questionnaires and face-to-face interviews suggest that our sample experienced very few symptoms of constipation (PAC-SYM) and that the condition itself did not have a major impact upon their quality of life (PAC-QOL). The low level of symptoms of constipation is most likely explained by 90% of the sample using a laxative in the previous week. Most participants in our sample were satisfied with the performance of their laxatives, and levels of anxiety and depression were low. Their fibre consumption was classified as 'moderate' but their average water consumption fell below the recommended guidelines. Daily diaries, completed each day for a period of 6 months, were analysed primarily in terms of overall response rate and item response rates, and the participants accepted this method of data collection. For the economic evaluation, all of the trial arms experienced a reduction in utility, as measured by EQ-5D. There was no statistical evidence to suggest that either the personalised intervention arm or the standardised intervention arm was associated with significant changes in utility at 3 months compared with the control arm. Data on related health-care costs show a cost saving of £13.34 for those in the personalised arm, compared with the control arm, and a smaller cost saving for the standardised arm. These savings primarily occurred because of reduced hospital costs. There was no significant change measured in utility, so the personalised arm appeared to be the preferred course, producing the greatest cost savings. Due to the low number of participants in the trial, no firm conclusions could be drawn about the effectiveness of the interventions. However, a number of factors that contributed to the conduct and progress of the trial are highlighted, which may be relevant to others conducting research on a similar topic or population. ISRCTN73881345. This project was funded by the NIHR Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 14, No. 52. See the HTA programme website for further project information.

  8. Method and apparatus for hybrid position/force control of multi-arm cooperating robots

    NASA Technical Reports Server (NTRS)

    Hayati, Samad A. (Inventor)

    1989-01-01

    Two or more robotic arms having end effectors rigidly attached to an object to be moved are disclosed. A hybrid position/force control system is provided for driving each of the robotic arms. The object to be moved is represented as having a total mass that consists of the actual mass of the object to be moved plus the mass of the moveable arms that are rigidly attached to the moveable object. The arms are driven in a positive way by the hybrid control system to assure that each arm shares in the position/force applied to the object. The burden of actuation is shared by each arm in a non-conflicting way as the arm independently control the position of, and force upon, a designated point on the object.

  9. A laboratory breadboard system for dual-arm teleoperation

    NASA Technical Reports Server (NTRS)

    Bejczy, A. K.; Szakaly, Z.; Kim, W. S.

    1990-01-01

    The computing architecture of a novel dual-arm teleoperation system is described. The novelty of this system is that: (1) the master arm is not a replica of the slave arm; it is unspecific to any manipulator and can be used for the control of various robot arms with software modifications; and (2) the force feedback to the general purpose master arm is derived from force-torque sensor data originating from the slave hand. The computing architecture of this breadboard system is a fully synchronized pipeline with unique methods for data handling, communication and mathematical transformations. The computing system is modular, thus inherently extendable. The local control loops at both sites operate at 100 Hz rate, and the end-to-end bilateral (force-reflecting) control loop operates at 200 Hz rate, each loop without interpolation. This provides high-fidelity control. This end-to-end system elevates teleoperation to a new level of capabilities via the use of sensors, microprocessors, novel electronics, and real-time graphics displays. A description is given of a graphic simulation system connected to the dual-arm teleoperation breadboard system. High-fidelity graphic simulation of a telerobot (called Phantom Robot) is used for preview and predictive displays for planning and for real-time control under several seconds communication time delay conditions. High fidelity graphic simulation is obtained by using appropriate calibration techniques.

  10. Transforaminal lumbar interbody graft placement using an articulating delivery arm facilitates increased segmental lordosis with superior anterior and midline graft placement.

    PubMed

    Shau, David N; Parker, Scott L; Mendenhall, Stephen K; Zuckerman, Scott L; Godil, Saniya S; Devin, Clinton J; McGirt, Matthew J

    2015-05-01

    Transforaminal lumbar interbody fusion (TLIF) is a frequently performed method of lumbar arthrodesis in patients failing medical management of back and leg pain. Accurate placement of the interbody graft and restoration of lordosis has been shown to be crucial when performing lumbar fusion procedures. We performed a single-surgeon, prospective, randomized study to determine whether a novel articulating versus traditional straight graft delivery arm system allows for superior graft placement and increased lordosis for single-level TLIF. Thirty consecutive patients undergoing single-level TLIF were included and prospectively randomized to one of the 2 groups (articulated vs. straight delivery arm system). Three radiographic characteristics were evaluated at 6-week follow-up: (1) degree of segmental lumbar lordosis at the fused level; (2) the percent anterior location of the interbody graft in disk space; and (3) the distance (mm) off midline of the interbody graft placement. Randomization yielded 16 patients in the articulated delivery arm cohort and 14 in the straight delivery arm cohort. The articulating delivery arm system yielded an average of 14.7-degree segmental lordosis at fused level, 35% anterior location, and 3.6 mm off midline. The straight delivery arm system yielded an average of 10.7-degree segmental lordosis at fused level, 46% anterior location, and 7.0 mm off midline. All 3 comparisons were statistically significant (P<0.05). The study suggests that an articulating delivery arm system facilitates superior anterior and midline TLIF graft placement allowing for increased segmental lordosis compared with a traditional straight delivery arm system.

  11. Anthropometry-corrected exposure modeling as a method to improve trunk posture assessment with a single inclinometer.

    PubMed

    Van Driel, Robin; Trask, Catherine; Johnson, Peter W; Callaghan, Jack P; Koehoorn, Mieke; Teschke, Kay

    2013-01-01

    Measuring trunk posture in the workplace commonly involves subjective observation or self-report methods or the use of costly and time-consuming motion analysis systems (current gold standard). This work compared trunk inclination measurements using a simple data-logging inclinometer with trunk flexion measurements using a motion analysis system, and evaluated adding measures of subject anthropometry to exposure prediction models to improve the agreement between the two methods. Simulated lifting tasks (n=36) were performed by eight participants, and trunk postures were simultaneously measured with each method. There were significant differences between the two methods, with the inclinometer initially explaining 47% of the variance in the motion analysis measurements. However, adding one key anthropometric parameter (lower arm length) to the inclinometer-based trunk flexion prediction model reduced the differences between the two systems and accounted for 79% of the motion analysis method's variance. Although caution must be applied when generalizing lower-arm length as a correction factor, the overall strategy of anthropometric modeling is a novel contribution. In this lifting-based study, by accounting for subject anthropometry, a single, simple data-logging inclinometer shows promise for trunk posture measurement and may have utility in larger-scale field studies where similar types of tasks are performed.

  12. Investigating Astromaterials Curation Applications for Dexterous Robotic Arms

    NASA Technical Reports Server (NTRS)

    Snead, C. J.; Jang, J. H.; Cowden, T. R.; McCubbin, F. M.

    2018-01-01

    The Astromaterials Acquisition and Curation office at NASA Johnson Space Center is currently investigating tools and methods that will enable the curation of future astromaterials collections. Size and temperature constraints for astromaterials to be collected by current and future proposed missions will require the development of new robotic sample and tool handling capabilities. NASA Curation has investigated the application of robot arms in the past, and robotic 3-axis micromanipulators are currently in use for small particle curation in the Stardust and Cosmic Dust laboratories. While 3-axis micromanipulators have been extremely successful for activities involving the transfer of isolated particles in the 5-20 micron range (e.g. from microscope slide to epoxy bullet tip, beryllium SEM disk), their limited ranges of motion and lack of yaw, pitch, and roll degrees of freedom restrict their utility in other applications. For instance, curators removing particles from cosmic dust collectors by hand often employ scooping and rotating motions to successfully free trapped particles from the silicone oil coatings. Similar scooping and rotating motions are also employed when isolating a specific particle of interest from an aliquot of crushed meteorite. While cosmic dust curators have been remarkably successful with these kinds of particle manipulations using handheld tools, operator fatigue limits the number of particles that can be removed during a given extraction session. The challenges for curation of small particles will be exacerbated by mission requirements that samples be processed in N2 sample cabinets (i.e. gloveboxes). We have been investigating the use of compact robot arms to facilitate sample handling within gloveboxes. Six-axis robot arms potentially have applications beyond small particle manipulation. For instance, future sample return missions may involve biologically sensitive astromaterials that can be easily compromised by physical interaction with a curator; other potential future returned samples may require cryogenic curation. Robot arms may be combined with high resolution cameras within a sample cabinet and controlled remotely by curator. Sophisticated robot arm and hand combination systems can be programmed to mimic the movements of a curator wearing a data glove; successful implementation of such a system may ultimately allow a curator to virtually operate in a nitrogen, cryogenic, or biologically sensitive environment with dexterity comparable to that of a curator physically handling samples in a glove box.

  13. Application of powder metallurgy techniques for the development of non-toxic ammunition. Final CRADA report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lowden, R.; Kelly, R.

    1997-05-30

    The purpose of the Cooperative Research and Development Agreement (CRADA) between Martin Marietta Energy Systems, Inc., and Delta Frangible Ammunition (DFA), was to identify and evaluate composite materials for the development of small arms ammunition. Currently available small arms ammunition utilizes lead as the major component of the projectile. The introduction of lead into the environment by these projectiles when they are expended is a rapidly increasing environmental problem. At certain levels, lead is a toxic metal to the environment and a continual health and safety concern for firearm users as well as those who must conduct lead recovery operationsmore » from the environment. DFA is a leading supplier of high-density mixtures, which will be used to replace lead-based ammunition in specific applications. Current non-lead ammunition has several limitations that prevent it from replacing lead-based ammunition in many applications (such as applications that require ballistics, weapon recoil, and weapon function identical to that of lead-based ammunition). The purpose of the CRADA was to perform the research and development to identify cost-effective materials to be used in small arms ammunition that eventually will be used in commercially viable, environmentally conscious, non-lead, frangible and/or non-frangible, ammunition.« less

  14. Three input concepts for flight crew interaction with information presented on a large-screen electronic cockpit display

    NASA Technical Reports Server (NTRS)

    Jones, Denise R.

    1990-01-01

    A piloted simulation study was conducted comparing three different input methods for interfacing to a large-screen, multiwindow, whole-flight-deck display for management of transport aircraft systems. The thumball concept utilized a miniature trackball embedded in a conventional side-arm controller. The touch screen concept provided data entry through a capacitive touch screen. The voice concept utilized a speech recognition system with input through a head-worn microphone. No single input concept emerged as the most desirable method of interacting with the display. Subjective results, however, indicate that the voice concept was the most preferred method of data entry and had the most potential for future applications. The objective results indicate that, overall, the touch screen concept was the most effective input method. There was also significant differences between the time required to perform specific tasks and the input concept employed, with each concept providing better performance relative to a specific task. These results suggest that a system combining all three input concepts might provide the most effective method of interaction.

  15. An application of data mining in district heating substations for improving energy performance

    NASA Astrophysics Data System (ADS)

    Xue, Puning; Zhou, Zhigang; Chen, Xin; Liu, Jing

    2017-11-01

    Automatic meter reading system is capable of collecting and storing a huge number of district heating (DH) data. However, the data obtained are rarely fully utilized. Data mining is a promising technology to discover potential interesting knowledge from vast data. This paper applies data mining methods to analyse the massive data for improving energy performance of DH substation. The technical approach contains three steps: data selection, cluster analysis and association rule mining (ARM). Two-heating-season data of a substation are used for case study. Cluster analysis identifies six distinct heating patterns based on the primary heat of the substation. ARM reveals that secondary pressure difference and secondary flow rate have a strong correlation. Using the discovered rules, a fault occurring in remote flow meter installed at secondary network is detected accurately. The application demonstrates that data mining techniques can effectively extrapolate potential useful knowledge to better understand substation operation strategies and improve substation energy performance.

  16. Health Care Providers in War and Armed Conflict: Operational and Educational Challenges in International Humanitarian Law and the Geneva Conventions, Part II. Educational and Training Initiatives.

    PubMed

    Burkle, Frederick M; Kushner, Adam L; Giannou, Christos; Paterson, Mary A; Wren, Sherry M; Burnham, Gilbert

    2018-05-07

    ABSTRACTNo discipline has been impacted more by war and armed conflict than health care has. Health systems and health care providers are often the first victims, suffering increasingly heinous acts that cripple the essential health delivery and public health infrastructure necessary for the protection of civilian and military victims of the state at war. This commentary argues that current instructional opportunities to prepare health care providers fall short in both content and preparation, especially in those operational skill sets necessary to manage multiple challenges, threats, and violations under international humanitarian law and to perform triage management in a resource-poor medical setting. Utilizing a historical framework, the commentary addresses the transformation of the education and training of humanitarian health professionals from the Cold War to today followed by recommendations for the future. (Disaster Med Public Health Preparedness. 2018;page 1 of 14).

  17. Holographic gunsights for small arms

    NASA Astrophysics Data System (ADS)

    Tai, Anthony M.; Sieczka, Eric J.; Radler, Richard; Upatnieks, Juris

    1996-05-01

    Holographic gunsights were first demonstrated in the mid 1970s by researchers at the Environmental Research Institute of Michigan (ERIM) under contracts with the Air Force and the Army. The sights utilized He-Ne gas lasers and were designed for use with large weapons systems. With the advent of low cost visible laser diode, ERIM formed a new company, EOTech, to develop, manufacture and market a holographic gun sight for small arms. A hologram is used to reconstruct the image of a reticle pattern that appears at the target plane. Unlike red-dot sights, virtually any reticle pattern, 2D or 3D, can be formed. The design challenges include an opto-mechanical package that is compact, light weight and low cost which can withstand recoils up to 4,000 Gs and provide fine elevation/windage pointing adjustments, and optics that are aberration-free and stable over a wide temperature range. Manufacturing challenges include the mass production of high quality holographic optics at low cost and the precision alignment of the very low f/number optics.

  18. DIABEO App Software and Telemedicine Versus Usual Follow-Up in the Treatment of Diabetic Patients: Protocol for the TELESAGE Randomized Controlled Trial

    PubMed Central

    Chaillous, Lucy; Franc, Sylvia; Benhamou, Pierre-Yves; Schaepelynck, Pauline; Hanaire, Hélène; Catargi, Bogdan; Farret, Anne; Fontaine, Pierre; Guerci, Bruno; Reznik, Yves; Penfornis, Alfred; Borot, Sophie; Serusclat, Pierre; Kherbachi, Yacine; D'Orsay, Geneviève; Detournay, Bruno; Simon, Pierre; Charpentier, Guillaume

    2018-01-01

    Background Self-management of diabetes minimizes the risk of macrovascular and microvascular complications, but understanding and/or adherence to self-management recommendations is often suboptimal. DIABEO is a smartphone app (downloaded via the internet) used to calculate bolus insulin doses. A previous study (TELEDIAB 1) showed that the use of DIABEO was associated with a significant improvement in glycemic control in patients with poorly controlled type 1 diabetes mellitus, particularly when combined with teleconsultations with physicians. Objective Here, we present the protocol for a new study (Suivi A Grande Echelle d’une cohorte de diabétiques de type 1 et de type 2 sous schéma insulinique basal bolus par la TELEmédecine; abbreviated TELESAGE), conducted in a larger population of diabetic patients with poorly controlled basal-bolus insulin levels. Methods TELESAGE is a multicenter, double-randomized, open-label, three parallel–arms study, conducted in approximately 100 centers in France. The study will compare a control group (arm 1: usual follow-up) with two DIABEO telemedicine systems: (1) physician-assisted telemedicine (arm 2), and (2) nurse-assisted telemonitoring and teleconsultations by a diabetologist’s task delegation (arm 3). Initial randomization will allocate the study arms in 12 French regions. A second randomization will assign patients in the groups allocated to each studied region. The primary objective of TELESAGE will be to investigate the effect of the DIABEO telemedicine system versus usual follow-up, with respect to improvements in the glycated hemoglobin levels of approximately 696 diabetic patients with poorly controlled basal-bolus insulin levels. Results The TELESAGE study is sponsored by Sanofi (Gentilly, France). A primary completion date is expected in June 2018, and publication of results is expected within 6 months of work completion. Conclusions The TELESAGE study is expected to confirm the previous results of the TELEDIAB 1 study using a larger sample of diabetic patients. It is also expected to evaluate a nurse-assisted telemonitoring system. We will assess the potential of the DIABEO telemedicine service in terms of its utility and explore whether it can become an integral part of diabetes care for patients. Trial Registration ClinicalTrials.gov NCT02287532; https://clinicaltrials.gov/ct2/show/NCT02287532 (Archived by WebCite at http://www.webcitation.org/6ykajhJKd) PMID:29674306

  19. A System Dynamics Model of Serum Prostate-Specific Antigen Screening for Prostate Cancer.

    PubMed

    Palma, Anton; Lounsbury, David W; Schlecht, Nicolas F; Agalliu, Ilir

    2016-02-01

    Since 2012, US guidelines have recommended against prostate-specific antigen (PSA) screening for prostate cancer. However, evidence of screening benefit from the Prostate, Lung, Colorectal and Ovarian (PLCO) Cancer Screening trial and the European Randomized Study of Screening for Prostate Cancer has been inconsistent, due partly to differences in noncompliance and contamination. Using system dynamics modeling, we replicated the PLCO trial and extrapolated follow-up to 20 years. We then simulated 3 scenarios correcting for contamination in the PLCO control arm using Surveillance, Epidemiology, and End Results (SEER) incidence and survival data collected prior to the PSA screening era (scenario 1), SEER data collected during the PLCO trial period (1993-2001) (scenario 2), and data from the European trial's control arm (1991-2005) (scenario 3). In all scenarios, noncompliance was corrected using incidence and survival rates for men with screen-detected cancer in the PLCO screening arm. Scenarios 1 and 3 showed a benefit of PSA screening, with relative risks of 0.62 (95% confidence interval: 0.53, 0.72) and 0.70 (95% confidence interval: 0.59, 0.83) for cancer-specific mortality after 20 years, respectively. In scenario 2, however, there was no benefit of screening. This simulation showed that after correcting for noncompliance and contamination, there is potential benefit of PSA screening in reducing prostate cancer mortality. It also demonstrates the utility of system dynamics modeling for synthesizing epidemiologic evidence to inform public policy. © The Author 2015. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  20. Considering the Creation of a Domestic Intelligence Agency in the United States: Lessons from the Experiences of Australia, Canada, France, Germany, and the United Kingdom

    DTIC Science & Technology

    2009-01-01

    Police AG Attorney-General AIC Australian intelligence community ANAO Australian National Audit Office AQMI Al-Qaida pour le Maghreb Islamique [al...Democratic Republic GIA Groupe Islamique Armé [Armed Islamic Group] xviii Considering the Creation of a Domestic Intelligence Agency in the United...health, energy, utilities, transport, manufacturing, communications, banking and finance , government services and icons, and public gatherings. 17

  1. 48 CFR 225.7703 - Acquisition of products or services other than small arms.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 3 2011-10-01 2011-10-01 false Acquisition of products or services other than small arms. 225.7703 Section 225.7703 Federal Acquisition Regulations System DEFENSE... than small arms. ...

  2. 48 CFR 225.7703 - Acquisition of products or services other than small arms.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Acquisition of products or services other than small arms. 225.7703 Section 225.7703 Federal Acquisition Regulations System DEFENSE... than small arms. ...

  3. 48 CFR 225.7703 - Acquisition of products or services other than small arms.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 3 2012-10-01 2012-10-01 false Acquisition of products or services other than small arms. 225.7703 Section 225.7703 Federal Acquisition Regulations System DEFENSE... than small arms. ...

  4. A software toolbox for robotics

    NASA Technical Reports Server (NTRS)

    Sanwal, J. C.

    1985-01-01

    A method for programming cooperating manipulators, which is guided by a geometric description of the task to be performed, is given. For this a suitable language must be used and a method for describing the workplace and the objects in it in geometric terms. A task level command language and its implementation for concurrently driven multiple robot arm is described. The language is suitable for driving a cell in which manipulators, end effectors, and sensors are controlled by their own dedicated processors. These processors can communicate with each other through a communication network. A mechanism for keeping track of the history of the commands already executed allows the command language for the manipulators to be event driven. A frame based world modeling system is utilized to describe the objects in the work environment and any relationships that hold between these objects. This system provides a versatile tool for managing information about the world model. Default actions normally needed are invoked when the data base is updated or accessed. Most of the first level error recovery is also invoked by the database by utilizing the concepts of demons. The package can be utilized to generate task level commands in a problem solver or a planner.

  5. Independent Orbiter Assessment (IOA): Analysis of the remote manipulator system

    NASA Technical Reports Server (NTRS)

    Tangorra, F.; Grasmeder, R. F.; Montgomery, A. D.

    1987-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items (PCIs). To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The independent analysis results for the Orbiter Remote Manipulator System (RMS) are documented. The RMS hardware and software are primarily required for deploying and/or retrieving up to five payloads during a single mission, capture and retrieve free-flying payloads, and for performing Manipulator Foot Restraint operations. Specifically, the RMS hardware consists of the following components: end effector; displays and controls; manipulator controller interface unit; arm based electronics; and the arm. The IOA analysis process utilized available RMS hardware drawings, schematics and documents for defining hardware assemblies, components and hardware items. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. Of the 574 failure modes analyzed, 413 were determined to be PCIs.

  6. Dexterous Humanoid Robotic Wrist

    NASA Technical Reports Server (NTRS)

    Ihrke, Chris A. (Inventor); Bridgwater, Lyndon (Inventor); Reich, David M. (Inventor); Wampler, II, Charles W. (Inventor); Askew, Scott R. (Inventor); Diftler, Myron A. (Inventor); Nguyen, Vienny (Inventor)

    2013-01-01

    A humanoid robot includes a torso, a pair of arms, a neck, a head, a wrist joint assembly, and a control system. The arms and the neck movably extend from the torso. Each of the arms includes a lower arm and a hand that is rotatable relative to the lower arm. The wrist joint assembly is operatively defined between the lower arm and the hand. The wrist joint assembly includes a yaw axis and a pitch axis. The pitch axis is disposed in a spaced relationship to the yaw axis such that the axes are generally perpendicular. The pitch axis extends between the yaw axis and the lower arm. The hand is rotatable relative to the lower arm about each of the yaw axis and the pitch axis. The control system is configured for determining a yaw angle and a pitch angle of the wrist joint assembly.

  7. The inter-arm systolic blood pressure difference and risk of cardiovascular mortality: A meta-analysis of cohort studies.

    PubMed

    Zhou, Ming; Gao, Zhen; Chen, Fei; Xu, Haijun; Dong, Xiao; Ma, Li

    2016-01-01

    The inter-arm systolic blood pressure difference (SBPD) is recommended to be in relation to potential cardiovascular disease (CVD). Previous studies yielded controversial results about the association between an inter-arm SBPD ≥ 10 mmHg or ≥15 mmHg and the risk of cardiovascular mortality. Therefore, we conducted this meta-analysis to investigate this association. We searched PubMed and Embase databases through December 31, 2014, and examined the references of retrieved articles to identify relevant cohort studies. We utilized Newcastle-Ottawa scale to assess the quality of included studies and calculated the summary risk estimates in a fixed/random-effect model. All data analyses were conducted using STATA version 11.0. A total of seven studies were identified. Compared with participants with an inter-arm SBPD < 10 mmHg, the pooled hazard ratio (HR) of CVD mortality of those with an inter-arm SBPD ≥ 10 mmHg was 1.58 (95% CI: 1.3-1.93), and the pooled HR of cardiovascular mortality of participants with an inter-arm SBPD ≥ 15 mmHg versus those with an inter-arm SBPD < 15 mmHg was 1.88 (95% CI: 1.33-2.66). The findings from the present meta-analysis indicated that the detection of an inter-arm SBPD may define a subpopulation at high risk of CVD events.

  8. Numerical Simulations of TRMM LBA, TOGA, COARE, GATE, ARM and PRESTORM Convective Systems: Sensitivity tests on Microphysical Processes

    NASA Technical Reports Server (NTRS)

    Tao, W.-K.; Wang, Y.; Lang, S.; Ferrier, B.; Simpson, J.; Einaudi, Franco (Technical Monitor)

    2000-01-01

    The 3D Goddard Cumulus Ensemble (GCE) model was utilized to examine the behavior and response of simulated deep tropical cloud systems that occurred over the west Pacific warm pool region, the Atlantic ocean and the central United States. The periods chosen for simulation were convectively active periods during TOGA-COARE (February 22 1993, December 11-17, 1992; December 19-28, February 9-13, 1993), GATE (September 4, 1974), LBA (January 26 and February 23, 1998), ARM (1997 IOP) and PRESTORM (June 11, 1985). We will examine differences in the microphysics for both warm rain and ice processes (evaporation /sublimation and condensation/ deposition), Q1 (Temperature), Q2 (Water vapor) and Q3 (momentum both U and V) budgets for these three convective events from different large-scale environments. The contribution of stratiform precipitation and its relationship to the vertical shear of the large-scale horizontal wind will also be examined. New improvements to the GCE model (i.e., microphysics: 4ICE two moments and 3ICE one moment; advection schemes) as well as their sensitivity to the model results will be discussed. Preliminary results indicated that various microphysical schemes could have a major impact on stratiform formation as well as the size of convective systems. However, they do not change the major characteristics of the convective systems, such as: arc shape, strong rotational circulation on both ends of system, heavy precipitation along the leading edge of systems.

  9. Resilin-like polypeptide-poly(ethylene gylcol) hybrid hydrogels for mechanically-demanding tissue engineering applications

    NASA Astrophysics Data System (ADS)

    McGann, Christopher Leland

    Technological progress in the life sciences and engineering has combined with important insights in the fields of biology and material science to make possible the development of biological substitutes which aim to restore function to damaged tissue. Numerous biomimetic hydrogels have been developed with the purpose of harnessing the regenerative capacity of cells and tissue through the rational deployment of biological signals. Aided by recombinant DNA technology and protein engineering methods, a new class of hydrogel precursor, the biosynthetic protein polymer, has demonstrated great promise towards the development of highly functional tissue engineering materials. In particular, protein polymers based upon resilin, a natural protein elastomer, have demonstrated outstanding mechanical properties that would have great value in soft tissue applications. This dissertation introduces hybrid hydrogels composed of recombinant resilin-like polypeptides (RLPs) cross-linked with multi-arm PEG macromers. Two different chemical strategies were employed to form RLP-PEG hydrogels: one utilized a Michael-type addition reaction between the thiols of cysteine residues present within the RLP and vinyl sulfone moieties functionalized on a multi-arm PEG macromer; the second system cross-links a norbornene-functionalized RLP with a thiol-functionalized multi-arm PEG macromer via a photoinitiated thiol-ene step polymerization. Oscillatory rheology and tensile testing confirmed the formation of elastic, resilient hydrogels in the RLP-PEG system cross-linked via Michael-type addition. These hydrogels supported the encapsulation and culture of both human aortic adventitial fibroblasts and human mesenchymal stem cells. Additionally, these RLP-PEG hydrogels exhibited phase separation behavior during cross-linking that led to the formation of a heterogeneous microstructure. Degradation could be triggered through incubation with matrix metalloproteinase. Photocross-linking was conferred to RLPs through the successful conjugation of norbornene acid to the protein. Oscillatory rheology characterized the gelation and subsequent mechanical properties of the photoreactive RLP-PEG hydrogels while the cytocompatibility was confirmed via the successful encapsulation and culture of human mesenchymal stem cells. Both strategies demonstrate the utility of hybrid materials that combine biosynthetic proteins with synthetic polymers. As resilient and cytocompatible materials, RLP-PEG hybrid hydrogels offer an exciting strategy towards the development of biomimetic tissue engineering scaffolds for mechanically-demanding applications.

  10. Changes in arm tissue composition with slowly progressive weight-lifting among women with breast cancer-related lymphedema.

    PubMed

    Zhang, Xiaochen; Brown, Justin C; Paskett, Electra D; Zemel, Babette S; Cheville, Andrea L; Schmitz, Kathryn H

    2017-07-01

    Studies in breast cancer-related lymphedema (BRCL) have exclusively examined total arm volume, but not the specific tissue composition that contributes to total volume. We evaluated baseline differences in arm tissue composition [fat mass, lean mass, bone mineral content (BMC), and bone mineral density (BMD)] between the affected and unaffected arms in women with BRCL. We compared changes in arm tissue composition and self-reported lymphedema symptoms after 1 year of weight-lifting versus control. We utilized data from physical activity and lymphedema trial that included 141 women with BRCL. Arm tissue composition was quantified using dual-energy X-ray absorptiometry. The severity of lymphedema was quantified using self-report survey. Weight-lifting was performed at community fitness facilities. At baseline, the affected arm had more fat (∆ = 89.7 g; P < 0.001) and lean mass (∆ = 149.1 g; P < 0.001), but less BMC (∆ = -3.2 g; P < 0.001) and less BMD (∆ = -5.5 mg/cm 2 ; P = 0.04) than the unaffected arm. After 12 months of weight-lifting, composition of the affected arm was improved: lean mass (71.2 g; P = 0.01) and BMD (14.0 mg/cm 2 ; P = 0.02) increased, arm fat percentage decreased (-1.5%; P = 0.003). Composition of the unaffected arm was only improved in lean mass (65.2 g; P = 0·04). Increases in lean mass were associated with less severe BCRL symptoms. Among women with BRCL, slowly progressive weight-lifting could improve arm tissue composition. Changes in arm tissue composition predict changes in symptom burden. Investigating the combined effects of exercise and weight loss on arm tissue composition and BCRL symptoms may provide additional insight into the benefits of lifestyle modification on lymphedema biology.

  11. Vector-algebra approach to extract Denavit-Hartenberg parameters of assembled robot arms

    NASA Technical Reports Server (NTRS)

    Barker, L. K.

    1983-01-01

    The Denavit-Hartenberg parameters characterize the joint axis systems in a robot arm and, naturally, appear in the transformation matrices from one joint axis system to another. These parameters are needed in the control of robot arms and in the passage of sensor information along the arm. This paper presents a vector algebra method to determine these parameters for any assembled robot arm. The idea is to measure the location of the robot hand (or extension) for different joint angles and then use these measurements to calculate the parameters.

  12. A Bayesian pick-the-winner design in a randomized phase II clinical trial.

    PubMed

    Chen, Dung-Tsa; Huang, Po-Yu; Lin, Hui-Yi; Chiappori, Alberto A; Gabrilovich, Dmitry I; Haura, Eric B; Antonia, Scott J; Gray, Jhanelle E

    2017-10-24

    Many phase II clinical trials evaluate unique experimental drugs/combinations through multi-arm design to expedite the screening process (early termination of ineffective drugs) and to identify the most effective drug (pick the winner) to warrant a phase III trial. Various statistical approaches have been developed for the pick-the-winner design but have been criticized for lack of objective comparison among the drug agents. We developed a Bayesian pick-the-winner design by integrating a Bayesian posterior probability with Simon two-stage design in a randomized two-arm clinical trial. The Bayesian posterior probability, as the rule to pick the winner, is defined as probability of the response rate in one arm higher than in the other arm. The posterior probability aims to determine the winner when both arms pass the second stage of the Simon two-stage design. When both arms are competitive (i.e., both passing the second stage), the Bayesian posterior probability performs better to correctly identify the winner compared with the Fisher exact test in the simulation study. In comparison to a standard two-arm randomized design, the Bayesian pick-the-winner design has a higher power to determine a clear winner. In application to two studies, the approach is able to perform statistical comparison of two treatment arms and provides a winner probability (Bayesian posterior probability) to statistically justify the winning arm. We developed an integrated design that utilizes Bayesian posterior probability, Simon two-stage design, and randomization into a unique setting. It gives objective comparisons between the arms to determine the winner.

  13. A low-cost tracked C-arm (TC-arm) upgrade system for versatile quantitative intraoperative imaging.

    PubMed

    Amiri, Shahram; Wilson, David R; Masri, Bassam A; Anglin, Carolyn

    2014-07-01

    C-arm fluoroscopy is frequently used in clinical applications as a low-cost and mobile real-time qualitative assessment tool. C-arms, however, are not widely accepted for applications involving quantitative assessments, mainly due to the lack of reliable and low-cost position tracking methods, as well as adequate calibration and registration techniques. The solution suggested in this work is a tracked C-arm (TC-arm) which employs a low-cost sensor tracking module that can be retrofitted to any conventional C-arm for tracking the individual joints of the device. Registration and offline calibration methods were developed that allow accurate tracking of the gantry and determination of the exact intrinsic and extrinsic parameters of the imaging system for any acquired fluoroscopic image. The performance of the system was evaluated in comparison to an Optotrak[Formula: see text] motion tracking system and by a series of experiments on accurately built ball-bearing phantoms. Accuracies of the system were determined for 2D-3D registration, three-dimensional landmark localization, and for generating panoramic stitched views in simulated intraoperative applications. The system was able to track the center point of the gantry with an accuracy of [Formula: see text] mm or better. Accuracies of 2D-3D registrations were [Formula: see text] mm and [Formula: see text]. Three-dimensional landmark localization had an accuracy of [Formula: see text] of the length (or [Formula: see text] mm) on average, depending on whether the landmarks were located along, above, or across the table. The overall accuracies of the two-dimensional measurements conducted on stitched panoramic images of the femur and lumbar spine were 2.5 [Formula: see text] 2.0 % [Formula: see text] and [Formula: see text], respectively. The TC-arm system has the potential to achieve sophisticated quantitative fluoroscopy assessment capabilities using an existing C-arm imaging system. This technology may be useful to improve the quality of orthopedic surgery and interventional radiology.

  14. Nutritional status at diagnosis in children with cancer. 2. An assessment by arm anthropometry.

    PubMed

    Barr, Ronald; Collins, Laura; Nayiager, Trishana; Doring, Nancy; Kennedy, Charlene; Halton, Jacqueline; Walker, Scott; Sala, Alessandra; Webber, Colin

    2011-04-01

    Assessment of nutritional status in children with cancer is important but measures based on weight can be problematic at diagnosis, especially in those with advanced disease. Likewise, dual energy x-ray absorptiometry may be confounded by other radiological procedures and is not commonly available in low-income countries where most children with cancer live. Arm anthropometry is not subject to these constraints. In a study sample of 99 Canadian patients with cancer at diagnosis, mid-upper arm circumference correlated well with lean body mass as measured by dual energy x-ray absorptiometry but triceps skin fold thickness was a poor predictor of fat mass. Arm anthropometry can be a useful tool for the measurement of nutritional status in children with cancer. However, further studies, particularly in low-income countries and in children with solid tumors at diagnosis, are required to determine the full extent of its utility.

  15. 49 CFR 234.223 - Gate arm.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Gate arm. 234.223 Section 234.223 Transportation... SYSTEMS Maintenance, Inspection, and Testing Maintenance Standards § 234.223 Gate arm. Each gate arm, when... maintained in a condition sufficient to be clearly viewed by approaching highway users. Each gate arm shall...

  16. 49 CFR 234.223 - Gate arm.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Gate arm. 234.223 Section 234.223 Transportation... SYSTEMS Maintenance, Inspection, and Testing Maintenance Standards § 234.223 Gate arm. Each gate arm, when... maintained in a condition sufficient to be clearly viewed by approaching highway users. Each gate arm shall...

  17. 49 CFR 234.223 - Gate arm.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Gate arm. 234.223 Section 234.223 Transportation... SYSTEMS Maintenance, Inspection, and Testing Maintenance Standards § 234.223 Gate arm. Each gate arm, when... maintained in a condition sufficient to be clearly viewed by approaching highway users. Each gate arm shall...

  18. Comparison of forearm and upper arm blood pressures.

    PubMed

    Singer, A J; Kahn, S R; Thode, H C; Hollander, J E

    1999-01-01

    In the prehospital setting it is not always feasible to obtain blood pressure (BP) readings from the upper arm. This study was performed to compare BPs obtained from subjects' forearms and upper arms in order to assess the utility of forearm BP as a surrogate for standard BP. The authors performed a prospective, cross-sectional, convenience study in a sample of ambulatory university ED patients, where each subject had sequential determinations of left upper arm and forearm BPs with an automated monitor at ED triage. The order of measurement was determined by the day of the week. Demographic and clinical data were also recorded. The main outcome measure was the correlation between upper arm and forearm systolic and diastolic BPs. Pearson's correlation coefficient and Student's t-test were used to analyze the data. 151 patients were enrolled. The mean age was 35.3+/-15.7 years; 40% were female and 78% were white. The mean forearm and upper arm systolic BPs were 129.8+/-20.7 mm Hg and 126.2+/-17.6 mm Hg (p = 0.002). The mean forearm and upper arm diastolic BPs were 80.7+/-14.5 mm Hg and 76.8+/-13.4 mm Hg (p<0.001). The correlations between forearm and upper arm systolic and diastolic BPs were 0.75 (p<0.001) and 0.72 (p<0.001). The differences between forearm and upper arm systolic and diastolic BPs were within 20 mm Hg in 86% and 94% of patients, respectively. Forearm BP is a fairly good predictor of standard upper arm BP in most patients. Forearm BP may be used when measurement of upper arm BP is not feasible.

  19. 48 CFR 908.7111 - Arms and ammunition.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Arms and ammunition. 908.7111 Section 908.7111 Federal Acquisition Regulations System DEPARTMENT OF ENERGY COMPETITION ACQUISITION PLANNING REQUIRED SOURCES OF SUPPLIES AND SERVICES Acquisition of Special Items 908.7111 Arms and...

  20. Evaluation of computational endomicroscopy architectures for minimally-invasive optical biopsy

    NASA Astrophysics Data System (ADS)

    Dumas, John P.; Lodhi, Muhammad A.; Bajwa, Waheed U.; Pierce, Mark C.

    2017-02-01

    We are investigating compressive sensing architectures for applications in endomicroscopy, where the narrow diameter probes required for tissue access can limit the achievable spatial resolution. We hypothesize that the compressive sensing framework can be used to overcome the fundamental pixel number limitation in fiber-bundle based endomicroscopy by reconstructing images with more resolvable points than fibers in the bundle. An experimental test platform was assembled to evaluate and compare two candidate architectures, based on introducing a coded amplitude mask at either a conjugate image or Fourier plane within the optical system. The benchtop platform consists of a common illumination and object path followed by separate imaging arms for each compressive architecture. The imaging arms contain a digital micromirror device (DMD) as a reprogrammable mask, with a CCD camera for image acquisition. One arm has the DMD positioned at a conjugate image plane ("IP arm"), while the other arm has the DMD positioned at a Fourier plane ("FP arm"). Lenses were selected and positioned within each arm to achieve an element-to-pixel ratio of 16 (230,400 mask elements mapped onto 14,400 camera pixels). We discuss our mathematical model for each system arm and outline the importance of accounting for system non-idealities. Reconstruction of a 1951 USAF resolution target using optimization-based compressive sensing algorithms produced images with higher spatial resolution than bicubic interpolation for both system arms when system non-idealities are included in the model. Furthermore, images generated with image plane coding appear to exhibit higher spatial resolution, but more noise, than images acquired through Fourier plane coding.

  1. Research on the man in the loop control system of the robot arm based on gesture control

    NASA Astrophysics Data System (ADS)

    Xiao, Lifeng; Peng, Jinbao

    2017-03-01

    The Man in the loop control system of the robot arm based on gesture control research complex real-world environment, which requires the operator to continuously control and adjust the remote manipulator, as the background, completes the specific mission human in the loop entire system as the research object. This paper puts forward a kind of robot arm control system of Man in the loop based on gesture control, by robot arm control system based on gesture control and Virtual reality scene feedback to enhance immersion and integration of operator, to make operator really become a part of the whole control loop. This paper expounds how to construct a man in the loop control system of the robot arm based on gesture control. The system is a complex system of human computer cooperative control, but also people in the loop control problem areas. The new system solves the problems that the traditional method has no immersion feeling and the operation lever is unnatural, the adjustment time is long, and the data glove mode wears uncomfortable and the price is expensive.

  2. Flight Telerobotic Servicer prototype simulator

    NASA Astrophysics Data System (ADS)

    Schein, Rob; Krauze, Linda; Hartley, Craig; Dickenson, Alan; Lavecchia, Tom; Working, Bob

    A prototype simulator for the Flight Telerobotic Servicer (FTS) system is described for use in the design development of the FTS, emphasizing the hand controller and user interface. The simulator utilizes a graphics workstation based on rapid prototyping tools for systems analyses of the use of the user interface and the hand controller. Kinematic modeling, manipulator-control algorithms, and communications programs are contained in the software for the simulator. The hardwired FTS panels and operator interface for use on the STS Orbiter are represented graphically, and the simulated controls function as the final FTS system configuration does. The robotic arm moves based on the user hand-controller interface, and the joint angles and other data are given on the prototype of the user interface. This graphics simulation tool provides the means for familiarizing crewmembers with the FTS system operation, displays, and controls.

  3. The effect of losses on the quantum-noise cancellation in the SU(1,1) interferometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xin, Jun; Wang, Hailong; Jing, Jietai, E-mail: jtjing@phy.ecnu.edu.cn

    Quantum-noise cancellation (QNC) is an effective method to control the noise of the quantum system, which reduces or even eliminates the noise of the quantum systems by utilizing destructive interference in the quantum system. However, QNC can be extremely dependent on the losses inside the system. In this letter, we experimentally and theoretically study how the losses can affect the QNC in the SU(1,1) interferometer. We find that losses in the different arms inside the SU(1,1) interferometer can have different effects on the QNC in the output fields from the SU(1,1) interferometer. And the QNC in the SU(1,1) interferometer canmore » almost be insensitive to the losses in some cases. Our findings may find its potential applications in the quantum noise control.« less

  4. 32 CFR 508.1 - Utilization of Army bands.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... (7) At official occasions and free social and entertainment activities held on or off Armed Forces installations, provided that such free social entertainment activities are conducted exclusively for the benefit...

  5. 32 CFR 508.1 - Utilization of Army bands.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... (7) At official occasions and free social and entertainment activities held on or off Armed Forces installations, provided that such free social entertainment activities are conducted exclusively for the benefit...

  6. 32 CFR 508.1 - Utilization of Army bands.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... (7) At official occasions and free social and entertainment activities held on or off Armed Forces installations, provided that such free social entertainment activities are conducted exclusively for the benefit...

  7. Atmospheric release model for the E-area low-level waste facility: Updates and modifications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None, None

    The atmospheric release model (ARM) utilizes GoldSim® Monte Carlo simulation software (GTG, 2017) to evaluate the flux of gaseous radionuclides as they volatilize from E-Area disposal facility waste zones, diffuse into the air-filled soil pores surrounding the waste, and emanate at the land surface. This report documents the updates and modifications to the ARM for the next planned E-Area PA considering recommendations from the 2015 PA strategic planning team outlined by Butcher and Phifer.

  8. Interactions of the innate and adaptive arms of the immune system in the pathogenesis of spondyloarthritis

    PubMed Central

    Stoll, Matthew L

    2011-01-01

    The immune system can be divided into the innate and adaptive arms. Historically, most of the research into the pathogenesis of spondyloarthritis (SpA) and other types of chronic arthritis focused on the adaptive immune system. Recently, the pendulum has shifted, and much current work in SpA focuses on innate immunity. Herein, I summarize evidence demonstrating that both the innate and the adaptive arms of the immune system are involved in the pathogenesis of SpA, propose a mechanism in which both arms interact to maintain chronic arthritis, and discuss potential research directions. PMID:21269576

  9. Quantitative assessment of ischemia and reactive hyperemia of the dermal layers using multi - spectral imaging on the human arm

    NASA Astrophysics Data System (ADS)

    Kainerstorfer, Jana M.; Amyot, Franck; Demos, Stavros G.; Hassan, Moinuddin; Chernomordik, Victor; Hitzenberger, Christoph K.; Gandjbakhche, Amir H.; Riley, Jason D.

    2009-07-01

    Quantitative assessment of skin chromophores in a non-invasive fashion is often desirable. Especially pixel wise assessment of blood volume and blood oxygenation is beneficial for improved diagnostics. We utilized a multi-spectral imaging system for acquiring diffuse reflectance images of healthy volunteers' lower forearm. Ischemia and reactive hyperemia was introduced by occluding the upper arm with a pressure cuff for 5min with 180mmHg. Multi-spectral images were taken every 30s, before, during and after occlusion. Image reconstruction for blood volume and blood oxygenation was performed, using a two layered skin model. As the images were taken in a non-contact way, strong artifacts related to the shape (curvature) of the arms were observed, making reconstruction of optical / physiological parameters highly inaccurate. We developed a curvature correction method, which is based on extracting the curvature directly from the intensity images acquired and does not require any additional measures on the object imaged. The effectiveness of the algorithm was demonstrated, on reconstruction results of blood volume and blood oxygenation for in vivo data during occlusion of the arm. Pixel wise assessment of blood volume and blood oxygenation was made possible over the entire image area and comparison of occlusion effects between veins and surrounding skin was performed. Induced ischemia during occlusion and reactive hyperemia afterwards was observed and quantitatively assessed. Furthermore, the influence of epidermal thickness on reconstruction results was evaluated and the exact knowledge of this parameter for fully quantitative assessment was pointed out.

  10. 48 CFR 237.109 - Services of quasi-military armed forces.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Services of quasi-military armed forces. 237.109 Section 237.109 Federal Acquisition Regulations System DEFENSE ACQUISITION... Contracts-General 237.109 Services of quasi-military armed forces. See 237.102-70b for prohibition on...

  11. HK022 Nun Requires Arginine-Rich Motif Residues Distinct from λ N

    PubMed Central

    Tawk, Caroline S.; Ghattas, Ingrid R.

    2015-01-01

    ABSTRACT Bacteriophage λ N protein binds boxB RNA hairpins in the nut (N utilization) sites of immediate early λ transcripts and interacts with host factors to suppress transcriptional termination at downstream terminators. In opposition to λ N, the Nun protein of HK022 binds the boxBs of coinfecting λ transcripts, interacts with a similar or identical set of host factors, and terminates transcription to suppress λ replication. Comparison of N-boxB and Nun-boxB nuclear magnetic resonance (NMR) structural models suggests similar interactions, though limited mutagenesis of Nun is available. Here, libraries of Nun's arginine-rich motif (ARM) were screened for the ability to exclude λ coinfection, and mutants were assayed for Nun termination with a boxB plasmid reporter system. Several Nun ARM residues appear to be immutable: Asp26, Arg28, Arg29, Arg32, Trp33, and Arg36. Asp26 and Trp33 appear to be unable to contact boxB and are not found at equivalent positions in λ N ARM. To understand if the requirement of Asp26, Trp33, and Arg36 indicated differences between HK022 Nun termination and λ N antitermination complexes, the same Nun libraries were fused to the activation domain of λ N and screened for clones able to complement N-deficient λ. Mutants were assayed for N antitermination. Surprisingly, Asp26 and Trp33 were still essential when Nun ARM was fused to N. Docking suggests that Nun ARM contacts a hydrophobic surface of the NusG carboxy-terminal domain containing residues necessary for Nun function. These findings indicate that Nun ARM relies on distinct contacts in its ternary complex and illustrate how protein-RNA recognition can evolve new regulatory functions. IMPORTANCE λ N protein interacts with host factors to allow λ nut-containing transcripts to elongate past termination signals. A competing bacteriophage, HK022, expresses Nun protein, which causes termination of λ nut transcripts. λ N and HK022 Nun use similar arginine-rich motifs (ARMs) to bind the same boxB RNAs in nut transcripts. Screening libraries of Nun ARM mutants, both in HK022 Nun and in a λ N fusion, revealed amino acids essential to Nun that could bind one or more host factors. Docking suggests that NusG, which is present in both Nun termination and N antitermination, is a plausible partner. These findings could help understand how transcription elongation is regulated and illustrate how subtle differences allow ARMs to evolve new regulatory functions. PMID:26350130

  12. HK022 Nun Requires Arginine-Rich Motif Residues Distinct from λ N.

    PubMed

    Tawk, Caroline S; Ghattas, Ingrid R; Smith, Colin A

    2015-11-01

    Bacteriophage λ N protein binds boxB RNA hairpins in the nut (N utilization) sites of immediate early λ transcripts and interacts with host factors to suppress transcriptional termination at downstream terminators. In opposition to λ N, the Nun protein of HK022 binds the boxBs of coinfecting λ transcripts, interacts with a similar or identical set of host factors, and terminates transcription to suppress λ replication. Comparison of N-boxB and Nun-boxB nuclear magnetic resonance (NMR) structural models suggests similar interactions, though limited mutagenesis of Nun is available. Here, libraries of Nun's arginine-rich motif (ARM) were screened for the ability to exclude λ coinfection, and mutants were assayed for Nun termination with a boxB plasmid reporter system. Several Nun ARM residues appear to be immutable: Asp26, Arg28, Arg29, Arg32, Trp33, and Arg36. Asp26 and Trp33 appear to be unable to contact boxB and are not found at equivalent positions in λ N ARM. To understand if the requirement of Asp26, Trp33, and Arg36 indicated differences between HK022 Nun termination and λ N antitermination complexes, the same Nun libraries were fused to the activation domain of λ N and screened for clones able to complement N-deficient λ. Mutants were assayed for N antitermination. Surprisingly, Asp26 and Trp33 were still essential when Nun ARM was fused to N. Docking suggests that Nun ARM contacts a hydrophobic surface of the NusG carboxy-terminal domain containing residues necessary for Nun function. These findings indicate that Nun ARM relies on distinct contacts in its ternary complex and illustrate how protein-RNA recognition can evolve new regulatory functions. λ N protein interacts with host factors to allow λ nut-containing transcripts to elongate past termination signals. A competing bacteriophage, HK022, expresses Nun protein, which causes termination of λ nut transcripts. λ N and HK022 Nun use similar arginine-rich motifs (ARMs) to bind the same boxB RNAs in nut transcripts. Screening libraries of Nun ARM mutants, both in HK022 Nun and in a λ N fusion, revealed amino acids essential to Nun that could bind one or more host factors. Docking suggests that NusG, which is present in both Nun termination and N antitermination, is a plausible partner. These findings could help understand how transcription elongation is regulated and illustrate how subtle differences allow ARMs to evolve new regulatory functions. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  13. Cost-utility analysis of percutaneous mitral valve repair in inoperable patients with functional mitral regurgitation in German settings.

    PubMed

    Borisenko, Oleg; Haude, Michael; Hoppe, Uta C; Siminiak, Tomasz; Lipiecki, Janusz; Goldberg, Steve L; Mehta, Nawzer; Bouknight, Omari V; Bjessmo, Staffan; Reuter, David G

    2015-05-14

    To determine the cost-effectiveness of the percutaneous mitral valve repair (PMVR) using Carillon® Mitral Contour System® (Cardiac Dimensions Inc., Kirkland, WA, USA) in patients with congestive heart failure accompanied by moderate to severe functional mitral regurgitation (FMR) compared to the prolongation of optimal medical treatment (OMT). Cost-utility analysis using a combination of a decision tree and Markov process was performed. The clinical effectiveness was determined based on the results of the Transcatheter Implantation of Carillon Mitral Annuloplasty Device (TITAN) trial. The mean age of the target population was 62 years, 77% of the patients were males, 64% of the patients had severe FMR and all patients had New York Heart Association functional class III. The epidemiological, cost and utility data were derived from the literature. The analysis was performed from the German statutory health insurance perspective over 10-year time horizon. Over 10 years, the total cost was €36,785 in the PMVR arm and €18,944 in the OMT arm. However, PMVR provided additional benefits to patients with an 1.15 incremental quality-adjusted life years (QALY) and an 1.41 incremental life years. The percutaneous procedure was cost-effective in comparison to OMT with an incremental cost-effectiveness ratio of €15,533/QALY. Results were robust in the deterministic sensitivity analysis. In the probabilistic sensitivity analysis with a willingness-to-pay threshold of €35,000/QALY, PMVR had a 84 % probability of being cost-effective. Percutaneous mitral valve repair may be cost-effective in inoperable patients with FMR due to heart failure.

  14. Anthropometric body measurements based on multi-view stereo image reconstruction.

    PubMed

    Li, Zhaoxin; Jia, Wenyan; Mao, Zhi-Hong; Li, Jie; Chen, Hsin-Chen; Zuo, Wangmeng; Wang, Kuanquan; Sun, Mingui

    2013-01-01

    Anthropometric measurements, such as the circumferences of the hip, arm, leg and waist, waist-to-hip ratio, and body mass index, are of high significance in obesity and fitness evaluation. In this paper, we present a home based imaging system capable of conducting anthropometric measurements. Body images are acquired at different angles using a home camera and a simple rotating disk. Advanced image processing algorithms are utilized for 3D body surface reconstruction. A coarse body shape model is first established from segmented body silhouettes. Then, this model is refined through an inter-image consistency maximization process based on an energy function. Our experimental results using both a mannequin surrogate and a real human body validate the feasibility of the proposed system.

  15. Anthropometric Body Measurements Based on Multi-View Stereo Image Reconstruction*

    PubMed Central

    Li, Zhaoxin; Jia, Wenyan; Mao, Zhi-Hong; Li, Jie; Chen, Hsin-Chen; Zuo, Wangmeng; Wang, Kuanquan; Sun, Mingui

    2013-01-01

    Anthropometric measurements, such as the circumferences of the hip, arm, leg and waist, waist-to-hip ratio, and body mass index, are of high significance in obesity and fitness evaluation. In this paper, we present a home based imaging system capable of conducting automatic anthropometric measurements. Body images are acquired at different angles using a home camera and a simple rotating disk. Advanced image processing algorithms are utilized for 3D body surface reconstruction. A coarse body shape model is first established from segmented body silhouettes. Then, this model is refined through an inter-image consistency maximization process based on an energy function. Our experimental results using both a mannequin surrogate and a real human body validate the feasibility of proposed system. PMID:24109700

  16. Optically controlled welding system

    NASA Technical Reports Server (NTRS)

    Gordon, Stephen S. (Inventor)

    1989-01-01

    An optically controlled welding system (10) wherein a welding torch (12) having through-the-torch viewing capabilities is provided with an optical beam splitter (56) to create a transmitted view and a reflective view of a welding operation. These views are converted to digital signals which are then processed and utilized by a computerized robotic welder (15) to make the welding torch responsive thereto. Other features includes an actively cooled electrode holder (26) which minimizes a blocked portion of the view by virtue of being constructed of a single spoke or arm (28) and a weld pool contour detector (14) comprising a laser beam directed onto the weld pool with the position of specular radiation reflected therefrom being characteristic of a penetrated or unpenetrated condition of the weld pool.

  17. Tension Stiffened and Tendon Actuated Manipulator

    NASA Technical Reports Server (NTRS)

    Dorsey, John T. (Inventor); Mercer, Charles D. (Inventor); Ganoe, George G. (Inventor); Doggett, William R. (Inventor); King, Bruce D. (Inventor); Jones, Thomas C. (Inventor); Corbin, Cole K. (Inventor)

    2015-01-01

    A tension stiffened and tendon actuated manipulator is provided performing robotic-like movements when acquiring a payload. The manipulator design can be adapted for use in-space, lunar or other planetary installations as it is readily configurable for acquiring and precisely manipulating a payload in both a zero-g environment and in an environment with a gravity field. The manipulator includes a plurality of link arms, a hinge connecting adjacent link arms together to allow the adjacent link arms to rotate relative to each other and a cable actuation and tensioning system provided between adjacent link arms. The cable actuation and tensioning system includes a spreader arm and a plurality of driven and non-driven elements attached to the link arms and the spreader arm. At least one cable is routed around the driven and non-driven elements for actuating the hinge.

  18. EXAMINING THE ROLE AND RESEARCH CHALLENGES OF SOCIAL MEDIA AS A TOOL FOR NONPROLIFERATION AND ARMS CONTROL TREATY VERIFICATION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Henry, Michael J.; Cramer, Nicholas O.; Benz, Jacob M.

    Traditional arms control treaty verification activities typically involve a combination of technical measurements via physical and chemical sensors, state declarations, political agreements, and on-site inspections involving international subject matter experts. However, the ubiquity of the internet, and the electronic sharing of data that it enables, has made available a wealth of open source information with the potential to benefit verification efforts. Open source information is already being used by organizations such as the International Atomic Energy Agency to support the verification of state-declared information, prepare inspectors for in-field activities, and to maintain situational awareness . The recent explosion in socialmore » media use has opened new doors to exploring the attitudes, moods, and activities around a given topic. Social media platforms, such as Twitter, Facebook, and YouTube, offer an opportunity for individuals, as well as institutions, to participate in a global conversation at minimal cost. Social media data can also provide a more data-rich environment, with text data being augmented with images, videos, and location data. The research described in this paper investigates the utility of applying social media signatures as potential arms control and nonproliferation treaty verification tools and technologies, as determined through a series of case studies. The treaty relevant events that these case studies touch upon include detection of undeclared facilities or activities, determination of unknown events recorded by the International Monitoring System (IMS), and the global media response to the occurrence of an Indian missile launch. The case studies examine how social media can be used to fill an information gap and provide additional confidence to a verification activity. The case studies represent, either directly or through a proxy, instances where social media information may be available that could potentially augment the evaluation of an event. The goal of this paper is to instigate a discussion within the verification community as to where and how social media can be effectively utilized to complement and enhance traditional treaty verification efforts. In addition, this paper seeks to identify areas of future research and development necessary to adapt social media analytic tools and techniques, and to form the seed for social media analytics to aid and inform arms control and nonproliferation policymakers and analysts. While social media analysis (as well as open source analysis as a whole) will not ever be able to replace traditional arms control verification measures, they do supply unique signatures that can augment existing analysis.« less

  19. Real-time simulation of three-dimensional shoulder girdle and arm dynamics.

    PubMed

    Chadwick, Edward K; Blana, Dimitra; Kirsch, Robert F; van den Bogert, Antonie J

    2014-07-01

    Electrical stimulation is a promising technology for the restoration of arm function in paralyzed individuals. Control of the paralyzed arm under electrical stimulation, however, is a challenging problem that requires advanced controllers and command interfaces for the user. A real-time model describing the complex dynamics of the arm would allow user-in-the-loop type experiments where the command interface and controller could be assessed. Real-time models of the arm previously described have not included the ability to model the independently controlled scapula and clavicle, limiting their utility for clinical applications of this nature. The goal of this study therefore was to evaluate the performance and mechanical behavior of a real-time, dynamic model of the arm and shoulder girdle. The model comprises seven segments linked by eleven degrees of freedom and actuated by 138 muscle elements. Polynomials were generated to describe the muscle lines of action to reduce computation time, and an implicit, first-order Rosenbrock formulation of the equations of motion was used to increase simulation step-size. The model simulated flexion of the arm faster than real time, simulation time being 92% of actual movement time on standard desktop hardware. Modeled maximum isometric torque values agreed well with values from the literature, showing that the model simulates the moment-generating behavior of a real human arm. The speed of the model enables experiments where the user controls the virtual arm and receives visual feedback in real time. The ability to optimize potential solutions in simulation greatly reduces the burden on the user during development.

  20. Modal analysis and control of flexible manipulator arms. Ph.D. Thesis

    NASA Technical Reports Server (NTRS)

    Neto, O. M.

    1974-01-01

    The possibility of modeling and controlling flexible manipulator arms was examined. A modal approach was used for obtaining the mathematical model and control techniques. The arm model was represented mathematically by a state space description defined in terms of joint angles and mode amplitudes obtained from truncation on the distributed systems, and included the motion of a two link two joint arm. Three basic techniques were used for controlling the system: pole allocation with gains obtained from the rigid system with interjoint feedbacks, Simon-Mitter algorithm for pole allocation, and sensitivity analysis with respect to parameter variations. An improvement in arm bandwidth was obtained. Optimization of some geometric parameters was undertaken to maximize bandwidth for various payload sizes and programmed tasks. The controlled system is examined under constant gains and using the nonlinear model for simulations following a time varying state trajectory.

  1. Robots testing robots: ALAN-Arm, a humanoid arm for the testing of robotic rehabilitation systems.

    PubMed

    Brookes, Jack; Kuznecovs, Maksims; Kanakis, Menelaos; Grigals, Arturs; Narvidas, Mazvydas; Gallagher, Justin; Levesley, Martin

    2017-07-01

    Robotics is increasing in popularity as a method of providing rich, personalized and cost-effective physiotherapy to individuals with some degree of upper limb paralysis, such as those who have suffered a stroke. These robotic rehabilitation systems are often high powered, and exoskeletal systems can attach to the person in a restrictive manner. Therefore, ensuring the mechanical safety of these devices before they come in contact with individuals is a priority. Additionally, rehabilitation systems may use novel sensor systems to measure current arm position. Used to capture and assess patient movements, these first need to be verified for accuracy by an external system. We present the ALAN-Arm, a humanoid robotic arm designed to be used for both accuracy benchmarking and safety testing of robotic rehabilitation systems. The system can be attached to a rehabilitation device and then replay generated or human movement trajectories, as well as autonomously play rehabilitation games or activities. Tests of the ALAN-Arm indicated it could recreate the path of a generated slow movement path with a maximum error of 14.2mm (mean = 5.8mm) and perform cyclic movements up to 0.6Hz with low gain (<1.5dB). Replaying human data trajectories showed the ability to largely preserve human movement characteristics with slightly higher path length and lower normalised jerk.

  2. 48 CFR 37.109 - Services of quasi-military armed forces.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... armed forces. 37.109 Section 37.109 Federal Acquisition Regulations System FEDERAL ACQUISITION... quasi-military armed forces. Contracts with Pinkerton Detective Agencies or similar organizations are...-military armed forces for hire, or with their employees, regardless of the contract's character. An...

  3. Form of the compensatory stepping response to repeated laterally directed postural disturbances.

    PubMed

    Hurt, Christopher P; Rosenblatt, Noah J; Grabiner, Mark D

    2011-10-01

    A compensatory stepping response (CSR) is a common strategy to restore dynamic stability in response to a postural disturbance. Currently, few studies have investigated the CSR to laterally directed disturbances delivered to subjects during quiet standing. The purpose of this study was to characterize the CSR of younger adults following exposure to a series of similar laterally directed disturbances for which no instructions were given with regard to the recovery response. We hypothesized that in the absence of externally applied constraints to the recovery response, subjects would be equally as likely to perform a crossover step as a sidestep sequence (SSS). We further hypothesized that there would be an asymmetry in arm abduction that would be dependent on the disturbance direction. Finally, we were interested in characterizing the effect of practice on the CSR to repeated disturbances. Ten younger adults were exposed to thirty laterally directed platform disturbances that forced a stepping response. Subjects responded by primarily utilizing a SSS that differs from previously reported results. Further, five of the ten subjects utilized a different recovery response that was dependent on the direction of the disturbance (i.e., left or right). Greater arm abduction was characterized for the arm in the direction of the external disturbance in comparison with the contralateral arm. Lastly, subjects modified their recovery response to this task within 12 disturbances. Taken together, these results suggest that recovery responses to laterally directed disturbances can be quickly modified but can be quite variable between and within subjects.

  4. 76 FR 43662 - 36(b)(1) Arms Sales Notification

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-21

    ... and control systems with modern technology. The new guidance and control system uses a mixture of... Issuance of Letter of Offer Pursuant to Section 36(b)(1) of the Arms Export Control Act, as amended (i... million TOTAL $86 million * as defined in Section 47(6) of the Arms Export Control Act. (iii) Description...

  5. Temporal characterization of small arms muzzle flash in the broadband visible

    NASA Astrophysics Data System (ADS)

    Burke, Tom; Bratlie, Duane

    2010-04-01

    The authors have developed a simple system for characterizing the muzzle flash duration of common military small-arms ammunition as a feeder for system design configurations. This paper is a synopsis of the efforts and results of the effort to characterize the broadband optical signature of modern small arms.

  6. Integrative rehabilitation of residents chronic post-stroke in skilled nursing facilities: the design and evaluation of the BrightArm Duo.

    PubMed

    House, G; Burdea, G; Polistico, K; Roll, D; Kim, J; Grampurohit, N; Damiani, F; Keeler, S; Hundal, J; Pollack, S

    2016-11-01

    To describe the novel BrightArm Duo bimanual upper extremity (UE) rehabilitation system; to determine its technology acceptance and clinical benefit for older hemiplegic participants. The system table tilted to adjust arm gravity loading. Participants wore arm supports that sensed grasp strength and wrist position on the table. Wrist weights further increased shoulder exertion. Games were designed to improve UE strength, motor function, cognition and emotive state and adapted automatically to each participant. The system underwent feasibility trials spanning 8 weeks in two skilled nursing facilities (SNFs). Participants were evaluated pre-therapy and post-therapy using standardized clinical measures. Computerized measures of supported arm reach, table tilt and number of arm repetitions were stored on a remote server. Seven participants had significant improvements in their active range of shoulder movement, supported arm reach, shoulder strength, grasp strength and their ability to focus. The group demonstrated higher arm function measured with FMA (p = 0.01) and CAHAI (p = 0.05), and had an improvement in depression (Becks Depression Inventory, II). BrightArm Duo technology was well accepted by participants with a rating of 4.4 out of 5 points. Given these findings, it will be beneficial to evaluate the BrightArm Duo application in SNF maintenance programs. Implications for Rehabilitation Integrative rehabilitation that addresses both physical and cognitive domains is promising for post-stroke maintenance in skilled nursing facilities. Simultaneous bilateral arm exercise may improve arm function in older hemiplegic patients several years after stroke. Virtual reality games that adapt to the patient can increase attention and working memory while decreasing depression in elderly.

  7. Beam rider for an Articulated Robot Manipulator (ARM) accurate positioning of long flexible manipulators

    NASA Technical Reports Server (NTRS)

    Malachowski, M. J.

    1990-01-01

    Laser beam positioning and beam rider modules were incorporated into the long hollow flexible segment of an articulated robot manipulator (ARM). Using a single laser beam, the system determined the position of the distal ARM endtip, with millimetric precision, in six degrees of freedom, at distances of up to 10 meters. Preliminary designs, using space rated technology for the critical systems, of a two segmented physical ARM, with a single and a dual degree of freedom articulation, were developed, prototyped, and tested. To control the positioning of the physical ARM, an indirect adaptive controller, which used the mismatch between the position of the laser beam under static and dynamic conditions, was devised. To predict the behavior of the system and test the concept, a computer simulation model was constructed. A hierarchical artificially intelligent real time ADA operating system program structure was created. The software was designed for implementation on a dedicated VME bus based Intel 80386 administered parallel processing multi-tasking computer system.

  8. Acceptance test report (MI-74067-009-00). SVWS access arm (Serial number AA-09-03) (drawing 75M08129-13)

    NASA Technical Reports Server (NTRS)

    Hagood, J. T.

    1973-01-01

    Acceptance tests were conducted at Kennedy Space Center of the Saturn Vehicle Workshop Spacecraft Access Arm and related equipment. The tests were conducted to prove complete system capability to operate satisfactorily under conditions required to support spacecraft operations and activities. The SVWS Access Arm, serial number AA-09-03, is a Command Module Service Arm, S/A 9, which was removed from the mobile launcher and modified to support the SVWS operations. The C/M environmental chamber was removed and a completely new chamber was installed. The retract system was redesigned to remove the automatic/remote control capability and replaced with a local manual control. The SVWS Access Arm System was successfully tested and supported spacecraft processing without major problems.

  9. The use of 'arms-length' organizations for health system change in Ontario, Canada: some observations by insiders.

    PubMed

    Pink, George H; Leatt, Peggy

    2003-01-01

    During the past decade, there has been substantial health system reform in the United States, United Kingdom, New Zealand, and many other countries. For the most part, Canada has not pursued 'big bang' health system change but rather a variety of strategies to achieve incremental change. In this paper, we present the ways in which three arms-length organizations have been used by government to effect incremental system change in Ontario during the past several years. We observe that, (1) the influence of politics and political interference can be reduced through an arms-length organization; (2) an arms-length organization with the power to make decisions entails more political risk for government and encounters more scrutiny and criticism by providers and the media than an organization with the power to recommend only; (3) an arms-length organization with a limited lifespan faces more delaying tactics by adversely affected parties than an organization without a limited lifespan; (4) an arms-length organization with perceived influence may attract causes that are not related to its mandate; (5) the importance and difficulty of communicating complex information about system change to a wide variety of audiences cannot be overstated; (6) system change informed by the use of expert opinion encounters less provider resistance and may result in better decisions; and (7) the reputation of the Chair and the perceived competence and experience of the CEO are critical success factors in the success of an arms-length organization.

  10. Effect of torso flexion on the lumbar torso extensor muscle sagittal plane moment arms.

    PubMed

    Jorgensen, Michael J; Marras, William S; Gupta, Purnendu; Waters, Thomas R

    2003-01-01

    Accurate anatomical inputs for biomechanical models are necessary for valid estimates of internal loading. The magnitude of the moment arm of the lumbar erector muscle group is known to vary as a function of such variables as gender. Anatomical evidence indicates that the moment arms decrease during torso flexion. However, moment arm estimates in biomechanical models that account for individual variability have been derived from imaging studies from supine postures. Quantify the sagittal plane moment arms of the lumbar erector muscle group as a function of torso flexion, and identify individual characteristics that are associated with the magnitude of the moment arms as a function of torso flexion. Utilization of a 0.3 Tesla Open magnetic resonance image (MRI) to image and quantify the moment arm of the right erector muscle group as a function of gender and torso flexion. Axial MRI images through and parallel to each of the lumbar intervertebral discs at four torso flexion angles were obtained from 12 male and 12 female subjects in a lateral recumbent posture. Multivariate analysis of variance was used to investigate the differences in the moment arms at different torso flexion angles, whereas hierarchical linear regression was used to investigate associations with individual anthropometric characteristics and spinal posture. The largest decrease in the lumbar erector muscle group moment arm from neutral to 45-degree flexion occurred at the L5-S1 level (9.7% and 8.9% for men and women, respectively). Measures of spinal curvature (L1-S1 lordosis), body mass and trunk characteristics (depth or circumference) were associated with the varying moment arm at most lumbar levels. The sagittal plane moment arms of the lumbar erector muscle mass decrease as the torso flexes forward. The change in moment arms as a function of torso flexion may have an impact on prediction of spinal loading in biomechanical models.

  11. Predicting Academic Success in a Post-Secondary Vocational Studies Program Utilizing the A. S. V. A. B. Part One.

    ERIC Educational Resources Information Center

    Dumont, Richard G.

    This study assesses the utility of the Armed Services Vocational Aptitude Battery (A.S.V.A.B.) in predicting the academic success of students enrolled in the Automotive Service Specialist curriculum at the State University of New York Agricultural and Technical College (Alfred, New York). This document, part I of a two-part study, describes the…

  12. Anthropometric considerations for a 4-axis side-arm flight controller

    NASA Technical Reports Server (NTRS)

    Debellis, W. B.

    1986-01-01

    A data base on multiaxis side-arm flight controls was generated. The rapid advances in fly-by-light technology, automatic stability systems, and onboard computers have combined to create flexible flight control systems which could reduce the workload imposed on the operator by complex new equipment. This side-arm flight controller combines four controls into one unit and should simplify the pilot's task. However, the use of a multiaxis side-arm flight controller without complete cockpit integration may tend to increase the pilot's workload.

  13. The apparent mass and mechanical impedance of the hand and the transmission of vibration to the fingers, hand, and arm

    NASA Astrophysics Data System (ADS)

    Concettoni, Enrico; Griffin, Michael

    2009-08-01

    Although hand-transmitted vibration causes injury and disease, most often evident in the fingers, the biodynamic responses of the fingers, hand, and arm are not yet well understood. A method of investigating the motion of the entire finger-hand-arm system, based on the simultaneous measurement of the biodynamic response at the driving point and the transmissibility to many points on the finger-hand-arm system, is illustrated. Fourteen male subjects participated in an experiment in which they pushed down on a vertically vibrating metal plate with their right forearm pronated and their elbow bent at 90°. The apparent mass and mechanical impedance of the finger-hand-arm system were measured for each of seven different contact conditions between the plate and the fingers and hand. Simultaneously, the vibration of the fingers, hand, and arm was measured at 41 locations using a scanning laser Doppler vibrometer. Transmissibilities showed how the vibration was transmitted along the arm and allowed the construction of spectral operating deflection shapes showing the vibration pattern of the fingers, hand, and arm for each of the seven contact conditions. The vibration patterns at critical frequencies for each contact condition have been used to explain features in the driving point biodynamic responses and the vibration behaviour of the hand-arm system. Spectral operating deflection shapes for the upper limb assist the interpretation of driving point biodynamic responses and help to advance understanding required to predict, explain, and control the various effects of hand-transmitted vibration.

  14. Topological analysis of long-chain branching patterns in polyolefins.

    PubMed

    Bonchev, D; Markel, E; Dekmezian, A

    2001-01-01

    Patterns in molecular topology and complexity for long-chain branching are quantitatively described. The Wiener number, the topological complexity index, and a new index of 3-starness are used to quantify polymer structure. General formulas for these indices were derived for the cases of 3-arm star, H-shaped, and B-arm comb polymers. The factors affecting complexity in monodisperse polymer systems are ranked as follows: number of arms > arm length > arm central position approximately equal to arm clustering > total molecular weight approximately equal to backbone molecular weight. Topological indices change rapidly and then plateau as the molecular weight of branches on a polyolefin backbone increases from 0 to 5 kD. Complexity calculations relate 2-arm or 3-arm comb structures to the corresponding 3-arm stars of equivalent complexity but much higher molecular weight. In a subsequent paper, we report the application of topological analysis for developing structure/property relationships for monodisperse polymers. While the focus of the present work is on the description of monodisperse, well-defined architectures, the methods may be extended to the description of polydisperse systems.

  15. A descriptive analysis of medical health services utilization of Veterans living in Ontario: a retrospective cohort study using administrative healthcare data.

    PubMed

    Aiken, Alice B; Mahar, Alyson L; Kurdyak, Paul; Whitehead, Marlo; Groome, Patti A

    2016-08-04

    Health services utilization by Veterans following release may be different than the general population as the result of occupational conditions, requirements and injuries. This study provides the first longitudinal overview of Canadian Veteran healthcare utilization in the Ontario public health system. This is a retrospective cohort study designed to use Ontario's provincial healthcare data to study the demographics and healthcare utilization of Canadian Armed Forces (CAF) & RCMP Veterans living in Ontario. Veterans were eligible for the study if they released between January 1, 1990 and March 31, 2013. Databases at the Institute for Clinical Evaluative Sciences were linked by a unique identifier to study non-mental health related hospitalizations, emergency department visits, and physician visits. Overall and age-stratified descriptive statistics were calculated in five-year intervals following the date of release. The cohort is comprised of 23, 818 CAF or RCMP Veterans. Following entry into the provincial healthcare system, 82.6 % (95 % CI 82.1-83.1) of Veterans saw their family physician at least once over the first five years following release, 60.7 % (95 % CI 60.0-61.3) saw a non-mental health specialist, 40.8 % (95 % CI 40.2-41.5) went to the emergency department in that same time period and 9.9 % (9.5-10.3) were hospitalized for non-mental health related complaints. Patterns of non-mental health services utilization appeared to be time and service dependant. Stratifying health services utilization by age of the Veteran at entry into the provincial healthcare system revealed significant differences in service use and intensity. This study provides the first description of health services utilization by Veterans, following release from the CAF or RCMP. This work will inform the planning and delivery of support to Veterans in Ontario.

  16. The Effect of a Mechanical Arm System on Portable Grinder Vibration Emissions.

    PubMed

    McDowell, Thomas W; Welcome, Daniel E; Warren, Christopher; Xu, Xueyan S; Dong, Ren G

    2016-04-01

    Mechanical arm systems are commonly used to support powered hand tools to alleviate ergonomic stressors related to the development of workplace musculoskeletal disorders. However, the use of these systems can increase exposure times to other potentially harmful agents such as hand-transmitted vibration. To examine how these tool support systems affect tool vibration, the primary objectives of this study were to characterize the vibration emissions of typical portable pneumatic grinders used for surface grinding with and without a mechanical arm support system at a workplace and to estimate the potential risk of the increased vibration exposure time afforded by the use of these mechanical arm systems. This study also developed a laboratory-based simulated grinding task based on the ISO 28927-1 (2009) standard for assessing grinder vibrations; the simulated grinding vibrations were compared with those measured during actual workplace grinder operations. The results of this study demonstrate that use of the mechanical arm may provide a health benefit by reducing the forces required to lift and maneuver the tools and by decreasing hand-transmitted vibration exposure. However, the arm does not substantially change the basic characteristics of grinder vibration spectra. The mechanical arm reduced the average frequency-weighted acceleration by about 24% in the workplace and by about 7% in the laboratory. Because use of the mechanical arm system can increase daily time-on-task by 50% or more, the use of such systems may actually increase daily time-weighted hand-transmitted vibration exposures in some cases. The laboratory acceleration measurements were substantially lower than the workplace measurements, and the laboratory tool rankings based on acceleration were considerably different than those from the workplace. Thus, it is doubtful that ISO 28927-1 is useful for estimating workplace grinder vibration exposures or for predicting workplace grinder acceleration rank orders. Published by Oxford University Press on behalf of the British Occupational Hygiene Society 2015.

  17. The Effect of a Mechanical Arm System on Portable Grinder Vibration Emissions

    PubMed Central

    McDowell, Thomas W.; Welcome, Daniel E.; Warren, Christopher; Xu, Xueyan S.; Dong, Ren G.

    2016-01-01

    Mechanical arm systems are commonly used to support powered hand tools to alleviate ergonomic stressors related to the development of workplace musculoskeletal disorders. However, the use of these systems can increase exposure times to other potentially harmful agents such as hand-transmitted vibration. To examine how these tool support systems affect tool vibration, the primary objectives of this study were to characterize the vibration emissions of typical portable pneumatic grinders used for surface grinding with and without a mechanical arm support system at a workplace and to estimate the potential risk of the increased vibration exposure time afforded by the use of these mechanical arm systems. This study also developed a laboratory-based simulated grinding task based on the ISO 28927-1 (2009) standard for assessing grinder vibrations; the simulated grinding vibrations were compared with those measured during actual workplace grinder operations. The results of this study demonstrate that use of the mechanical arm may provide a health benefit by reducing the forces required to lift and maneuver the tools and by decreasing hand-transmitted vibration exposure. However, the arm does not substantially change the basic characteristics of grinder vibration spectra. The mechanical arm reduced the average frequency-weighted acceleration by about 24% in the workplace and by about 7% in the laboratory. Because use of the mechanical arm system can increase daily time-on-task by 50% or more, the use of such systems may actually increase daily time-weighted hand-transmitted vibration exposures in some cases. The laboratory acceleration measurements were substantially lower than the workplace measurements, and the laboratory tool rankings based on acceleration were considerably different than those from the workplace. Thus, it is doubtful that ISO 28927-1 is useful for estimating workplace grinder vibration exposures or for predicting workplace grinder acceleration rank orders. PMID:26628522

  18. Dispersion analysis and measurement of potassium tantalate niobate crystals by broadband optical interferometers.

    PubMed

    Ren, Jian

    2017-01-10

    Electro-optic crystals, such as potassium tantalate niobate [KTa1-xNbxO3(KTN)], are enabling materials for many optical devices. Their utility in broadband applications heavily depends on their dispersion property. To this end, an analysis of dispersion mismatch in broadband optical interferometers is first presented. Then a method utilizing polynomial phase fitting to measure the dispersion property of materials composing the arms of an interferometer is introduced. As a demonstration, an interferometry system based on optical coherence tomography (OCT) was built, where, for the first time, the group velocity dispersion of a KTN crystal around 1310 nm was measured and numerically compensated for OCT imaging. Several advantages over a widely used method in OCT, which is based on metric functions, are discussed. The results show the fitting method can provide a more reliable measurement with reduced computation complexity.

  19. Overcoming Robot-Arm Joint Singularities

    NASA Technical Reports Server (NTRS)

    Barker, L. K.; Houck, J. A.

    1986-01-01

    Kinematic equations allow arm to pass smoothly through singular region. Report discusses mathematical singularities in equations of robotarm control. Operator commands robot arm to move in direction relative to its own axis system by specifying velocity in that direction. Velocity command then resolved into individual-joint rotational velocities in robot arm to effect motion. However, usual resolved-rate equations become singular when robot arm is straightened.

  20. Precision liquid level sensor

    DOEpatents

    Field, M.E.; Sullivan, W.H.

    A precision liquid level sensor utilizes a balanced bridge, each arm including an air dielectric line. Changes in liquid level along one air dielectric line imbalance the bridge and create a voltage which is directly measurable across the bridge.

  1. Task-Driven Orbit Design and Implementation on a Robotic C-Arm System for Cone-Beam CT.

    PubMed

    Ouadah, S; Jacobson, M; Stayman, J W; Ehtiati, T; Weiss, C; Siewerdsen, J H

    2017-03-01

    This work applies task-driven optimization to the design of non-circular orbits that maximize imaging performance for a particular imaging task. First implementation of task-driven imaging on a clinical robotic C-arm system is demonstrated, and a framework for orbit calculation is described and evaluated. We implemented a task-driven imaging framework to optimize orbit parameters that maximize detectability index d '. This framework utilizes a specified Fourier domain task function and an analytical model for system spatial resolution and noise. Two experiments were conducted to test the framework. First, a simple task was considered consisting of frequencies lying entirely on the f z -axis (e.g., discrimination of structures oriented parallel to the central axial plane), and a "circle + arc" orbit was incorporated into the framework as a means to improve sampling of these frequencies, and thereby increase task-based detectability. The orbit was implemented on a robotic C-arm (Artis Zeego, Siemens Healthcare). A second task considered visualization of a cochlear implant simulated within a head phantom, with spatial frequency response emphasizing high-frequency content in the ( f y , f z ) plane of the cochlea. An optimal orbit was computed using the task-driven framework, and the resulting image was compared to that for a circular orbit. For the f z -axis task, the circle + arc orbit was shown to increase d ' by a factor of 1.20, with an improvement of 0.71 mm in a 3D edge-spread measurement for edges located far from the central plane and a decrease in streak artifacts compared to a circular orbit. For the cochlear implant task, the resulting orbit favored complementary views of high tilt angles in a 360° orbit, and d ' was increased by a factor of 1.83. This work shows that a prospective definition of imaging task can be used to optimize source-detector orbit and improve imaging performance. The method was implemented for execution of non-circular, task-driven orbits on a clinical robotic C-arm system. The framework is sufficiently general to include both acquisition parameters (e.g., orbit, kV, and mA selection) and reconstruction parameters (e.g., a spatially varying regularizer).

  2. Task-driven orbit design and implementation on a robotic C-arm system for cone-beam CT

    NASA Astrophysics Data System (ADS)

    Ouadah, S.; Jacobson, M.; Stayman, J. W.; Ehtiati, T.; Weiss, C.; Siewerdsen, J. H.

    2017-03-01

    Purpose: This work applies task-driven optimization to the design of non-circular orbits that maximize imaging performance for a particular imaging task. First implementation of task-driven imaging on a clinical robotic C-arm system is demonstrated, and a framework for orbit calculation is described and evaluated. Methods: We implemented a task-driven imaging framework to optimize orbit parameters that maximize detectability index d'. This framework utilizes a specified Fourier domain task function and an analytical model for system spatial resolution and noise. Two experiments were conducted to test the framework. First, a simple task was considered consisting of frequencies lying entirely on the fz-axis (e.g., discrimination of structures oriented parallel to the central axial plane), and a "circle + arc" orbit was incorporated into the framework as a means to improve sampling of these frequencies, and thereby increase task-based detectability. The orbit was implemented on a robotic C-arm (Artis Zeego, Siemens Healthcare). A second task considered visualization of a cochlear implant simulated within a head phantom, with spatial frequency response emphasizing high-frequency content in the (fy, fz) plane of the cochlea. An optimal orbit was computed using the task-driven framework, and the resulting image was compared to that for a circular orbit. Results: For the fz-axis task, the circle + arc orbit was shown to increase d' by a factor of 1.20, with an improvement of 0.71 mm in a 3D edge-spread measurement for edges located far from the central plane and a decrease in streak artifacts compared to a circular orbit. For the cochlear implant task, the resulting orbit favored complementary views of high tilt angles in a 360° orbit, and d' was increased by a factor of 1.83. Conclusions: This work shows that a prospective definition of imaging task can be used to optimize source-detector orbit and improve imaging performance. The method was implemented for execution of non-circular, task-driven orbits on a clinical robotic C-arm system. The framework is sufficiently general to include both acquisition parameters (e.g., orbit, kV, and mA selection) and reconstruction parameters (e.g., a spatially varying regularizer).

  3. A common neural element receiving rhythmic arm and leg activity as assessed by reflex modulation in arm muscles

    PubMed Central

    Tazoe, Toshiki; Nakajima, Tsuyoshi; Futatsubashi, Genki; Ohtsuka, Hiroyuki; Suzuki, Shinya; Zehr, E. Paul; Komiyama, Tomoyoshi

    2016-01-01

    Neural interactions between regulatory systems for rhythmic arm and leg movements are an intriguing issue in locomotor neuroscience. Amplitudes of early latency cutaneous reflexes (ELCRs) in stationary arm muscles are modulated during rhythmic leg or arm cycling but not during limb positioning or voluntary contraction. This suggests that interneurons mediating ELCRs to arm muscles integrate outputs from neural systems controlling rhythmic limb movements. Alternatively, outputs could be integrated at the motoneuron and/or supraspinal levels. We examined whether a separate effect on the ELCR pathways and cortico-motoneuronal excitability during arm and leg cycling is integrated by neural elements common to the lumbo-sacral and cervical spinal cord. The subjects performed bilateral leg cycling (LEG), contralateral arm cycling (ARM), and simultaneous contralateral arm and bilateral leg cycling (A&L), while ELCRs in the wrist flexor and shoulder flexor muscles were evoked by superficial radial (SR) nerve stimulation. ELCR amplitudes were facilitated by cycling tasks and were larger during A&L than during ARM and LEG. A low stimulus intensity during ARM or LEG generated a larger ELCR during A&L than the sum of ELCRs during ARM and LEG. We confirmed this nonlinear increase in single motor unit firing probability following SR nerve stimulation during A&L. Furthermore, motor-evoked potentials following transcranial magnetic and electrical stimulation did not show nonlinear potentiation during A&L. These findings suggest the existence of a common neural element of the ELCR reflex pathway that is active only during rhythmic arm and leg movement and receives convergent input from contralateral arms and legs. PMID:26961103

  4. OSIRIS-REx Touch-and-Go (TAG) Mission Design for Asteroid Sample Collection

    NASA Technical Reports Server (NTRS)

    May, Alexander; Sutter, Brian; Linn, Timothy; Bierhaus, Beau; Berry, Kevin; Mink, Ron

    2014-01-01

    The Origins Spectral Interpretation Resource Identification Security Regolith Explorer (OSIRIS-REx) mission is a NASA New Frontiers mission launching in September 2016 to rendezvous with the near-Earth asteroid Bennu in October 2018. After several months of proximity operations to characterize the asteroid, OSIRIS-REx flies a Touch-And-Go (TAG) trajectory to the asteroid's surface to collect at least 60 g of pristine regolith sample for Earth return. This paper provides mission and flight system overviews, with more details on the TAG mission design and key events that occur to safely and successfully collect the sample. An overview of the navigation performed relative to a chosen sample site, along with the maneuvers to reach the desired site is described. Safety monitoring during descent is performed with onboard sensors providing an option to abort, troubleshoot, and try again if necessary. Sample collection occurs using a collection device at the end of an articulating robotic arm during a brief five second contact period, while a constant force spring mechanism in the arm assists to rebound the spacecraft away from the surface. Finally, the sample is measured quantitatively utilizing the law of conservation of angular momentum, along with qualitative data from imagery of the sampling device. Upon sample mass verification, the arm places the sample into the Stardust-heritage Sample Return Capsule (SRC) for return to Earth in September 2023.

  5. The effect of arm weight support on upper limb muscle synergies during reaching movements

    PubMed Central

    2014-01-01

    Background Compensating for the effect of gravity by providing arm-weight support (WS) is a technique often utilized in the rehabilitation of patients with neurological conditions such as stroke to facilitate the performance of arm movements during therapy. Although it has been shown that, in healthy subjects as well as in stroke survivors, the use of arm WS during the performance of reaching movements leads to a general reduction, as expected, in the level of activation of upper limb muscles, the effects of different levels of WS on the characteristics of the kinematics of motion and of the activity of upper limb muscles have not been thoroughly investigated before. Methods In this study, we systematically assessed the characteristics of the kinematics of motion and of the activity of 14 upper limb muscles in a group of 9 healthy subjects who performed 3-D arm reaching movements while provided with different levels of arm WS. We studied the hand trajectory and the trunk, shoulder, and elbow joint angular displacement trajectories for different levels of arm WS. Besides, we analyzed the amplitude of the surface electromyographic (EMG) data collected from upper limb muscles and investigated patterns of coordination via the analysis of muscle synergies. Results The characteristics of the kinematics of motion varied across WS conditions but did not show distinct trends with the level of arm WS. The level of activation of upper limb muscles generally decreased, as expected, with the increase in arm WS. The same eight muscle synergies were identified in all WS conditions. Their level of activation depended on the provided level of arm WS. Conclusions The analysis of muscle synergies allowed us to identify a modular organization underlying the generation of arm reaching movements that appears to be invariant to the level of arm WS. The results of this study provide a normative dataset for the assessment of the effects of the level of arm WS on muscle synergies in stroke survivors and other patients who could benefit from upper limb rehabilitation with arm WS. PMID:24594139

  6. 48 CFR 227.675-1 - International Traffic in Arms Regulations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Arms Regulations. 227.675-1 Section 227.675-1 Federal Acquisition Regulations System DEFENSE... COPYRIGHTS Foreign License and Technical Assistance Agreements 227.675-1 International Traffic in Arms... Munitions List as arms, ammunition, or munitions of war. (The Munitions List and pertinent procedures are...

  7. 48 CFR 227.675-1 - International Traffic in Arms Regulations.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Arms Regulations. 227.675-1 Section 227.675-1 Federal Acquisition Regulations System DEFENSE... COPYRIGHTS Foreign License and Technical Assistance Agreements 227.675-1 International Traffic in Arms... Munitions List as arms, ammunition, or munitions of war. (The Munitions List and pertinent procedures are...

  8. 48 CFR 227.675-1 - International Traffic in Arms Regulations.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Arms Regulations. 227.675-1 Section 227.675-1 Federal Acquisition Regulations System DEFENSE... COPYRIGHTS Foreign License and Technical Assistance Agreements 227.675-1 International Traffic in Arms... Munitions List as arms, ammunition, or munitions of war. (The Munitions List and pertinent procedures are...

  9. 48 CFR 227.675-1 - International Traffic in Arms Regulations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Arms Regulations. 227.675-1 Section 227.675-1 Federal Acquisition Regulations System DEFENSE... COPYRIGHTS Foreign License and Technical Assistance Agreements 227.675-1 International Traffic in Arms... Munitions List as arms, ammunition, or munitions of war. (The Munitions List and pertinent procedures are...

  10. 48 CFR 227.675-1 - International Traffic in Arms Regulations.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Arms Regulations. 227.675-1 Section 227.675-1 Federal Acquisition Regulations System DEFENSE... COPYRIGHTS Foreign License and Technical Assistance Agreements 227.675-1 International Traffic in Arms... Munitions List as arms, ammunition, or munitions of war. (The Munitions List and pertinent procedures are...

  11. ARM Unmanned Aerial Systems Implementation Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmid, Beat; Ivey, Mark

    Recent advances in Unmanned Aerial Systems (UAS) coupled with changes in the regulatory environment for operations of UAS in the National Airspace increase the potential value of UAS to the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility. UAS include unmanned aerial vehicles (UAV) and tethered balloon systems (TBS). The roles UAVs and TBSs could play within the ARM Facility, particularly science questions they could help address, have been discussed in several workshops, reports, and vision documents, including: This document describes the implementation of a robust and vigorous program for use of UAV and TBS formore » the science missions ARM supports.« less

  12. Human X-Linked genes regionally mapped utilizing X-autosome translocations and somatic cell hybrids.

    PubMed Central

    Shows, T B; Brown, J A

    1975-01-01

    Human genes coding for hypoxanthine phosphoribosyltransferase (HPRT, EC 2.4.2.8; IMP:pyrophosphate phosphoribosyltransferase), glucose-6-phosphate dehydrogenase (G6PD, EC 1.1.1.49; D-glucose-6-phosphate:NADP+ 1-oxidoreductase), and phosphoglycerate kinase (PGK, EC 2.7.2.3; ATP:3-phospho-D-glycerate 1-phosphotransferase) have been assigned to specific regions on the long arm of the X chromosome by somatic cell gentic techniques. Gene assignment and linear order were determined by employing human somatic cells possessing an X/9 translocation or an X/22 translocation in man-mouse cell hybridization studies. The X/9 translocation involved the majority of the X long arm translocated to chromosome 9 and the X/22 translocation involved the distal half of the X long arm translocated to 22. In each case these rearrangements appeared to be reciprocal. Concordant segregation of X-linked enzymes and segments of the X chromosome generated by the translocations indicated assignment of the PGK gene to a proximal long arm region (q12-q22) and the HPRT and G6PD genes to the distal half (q22-qter) of the X long arm. Further evidence suggests a gene order on the X long arm of centromere-PGK-HPRT-G6PD. Images PMID:1056018

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, P; Kuo, L; Yorke, E

    Purpose: To develop a biological modeling strategy which incorporates the response observed on the mid-treatment PET/CT into a dose escalation design for adaptive radiotherapy of non-small-cell lung cancer. Method: FDG-PET/CT was acquired midway through standard fractionated treatment and registered to pre-treatment planning PET/CT to evaluate radiation response of lung cancer. Each mid-treatment PET voxel was assigned the median SUV inside a concentric 1cm-diameter sphere to account for registration and imaging uncertainties. For each voxel, the planned radiation dose, pre- and mid-treatment SUVs were used to parameterize the linear-quadratic model, which was then utilized to predict the SUV distribution after themore » full prescribed dose. Voxels with predicted post-treatment SUV≥2 were identified as the resistant target (response arm). An adaptive simultaneous integrated boost was designed to escalate dose to the resistant target as high as possible, while keeping prescription dose to the original target and lung toxicity intact. In contrast, an adaptive target volume was delineated based only on the intensity of mid-treatment PET/CT (intensity arm), and a similar adaptive boost plan was optimized. The dose escalation capability of the two approaches was compared. Result: Images of three patients were used in this planning study. For one patient, SUV prediction indicated complete response and no necessary dose escalation. For the other two, resistant targets defined in the response arm were multifocal, and on average accounted for 25% of the pre-treatment target, compared to 67% in the intensity arm. The smaller response arm targets led to a 6Gy higher mean target dose in the adaptive escalation design. Conclusion: This pilot study suggests that adaptive dose escalation to a biologically resistant target predicted from a pre- and mid-treatment PET/CT may be more effective than escalation based on the mid-treatment PET/CT alone. More plans and ultimately clinical protocols are needed to validate this approach. MSKCC has a research agreement with Varian Medical System.« less

  14. Asteroid Redirect Mission: Update on Planetary Defense Demonstration and Small Bodies Benefits and Community Interaction

    NASA Astrophysics Data System (ADS)

    Reeves, D.; Mazanek, D. D.; Abell, P. A.; Brophy, J. R.; Chodas, P. W.; Cichy, B. D.

    2016-12-01

    The National Aeronautics and Space Administration (NASA) is developing the Asteroid Redirect Mission (ARM) to robotically visit a large near-Earth asteroid (NEA), collect a multi-ton boulder and regolith samples from its surface, demonstrate the enhanced gravity tractor (EGT) planetary defense technique, return the asteroidal material to a stable orbit around the Moon, and explore the returned material with a crewed mission in the mid-2020s. Recent analysis of the EGT has led to a change in the robotic baseline operations from a halo orbit, to an in-line stand-off. This study took into account the uncertainties in size and mass of the current reference target (2008 EV5), the desire to be able to perform the EGT operations with the collected boulder augmenting the spacecraft mass or with the spacecraft alone, the assumed capability of the ARM solar electric propulsion (SEP) system, and the extensibility to future planetary defense missions. This presentation will cover the findings that led to this change in the baseline, as well as the benefits that this EGT demonstration will provide. ARM is a capability and technology demonstration mission, which will also benefit our understanding of small bodies in the areas of science, planetary defense, and asteroidal resources and in-situ resource utilization (ISRU). The synergistic benefits of both the robotic and crewed segments will be discussed in addition to describing ARM's interaction with communities that are interested in small bodies, including: the Formulation Assessment and Support Team (FAST) effort, the Small Bodies Assessment Group (SBAG) Special Action Team (SAT) effort, and the upcoming Investigation Team (IT). The IT, which is expected to be announced in the spring of 2017, will assist the ARM project in the definition, design, development, and operations phases of the ARRM with the goal of maximizing the probability of mission success and the knowledge return from the mission.

  15. Validity of the Acti4 software using ActiGraph GT3X+accelerometer for recording of arm and upper body inclination in simulated work tasks.

    PubMed

    Korshøj, Mette; Skotte, Jørgen H; Christiansen, Caroline S; Mortensen, Pelle; Kristiansen, Jesper; Hanisch, Christiana; Ingebrigtsen, Jørgen; Holtermann, Andreas

    2014-01-01

    The validity of inclinometer measurements by ActiGraph GT3X+ (AG) accelerometer, when analysed with the Acti4 customised software, was examined by comparison of inclinometer measurements with a reference system (TrakStar) in a protocol with standardised arm movements and simulated working tasks. The sensors were placed at the upper arm (distal to the deltoid insertion) and at the spine (level of T1-T2) on eight participants. Root mean square errors (RMSEs) values of inclination between the two systems were low for the slow- and medium-speed standardised arm movements and in simulated working tasks. Fast arm movements caused the inclination estimated by the AG to deviate from the reference measurements (RMSE values up to ∼10°). Furthermore, it was found that AG positioned at the upper arm provided inclination data without bias compared to the reference system. These findings indicate that the AG provides valid estimates of arm and upper body inclination in working participants. Being inexpensive, small, water-resistant and without wires, ActiGraph GT3X+ seems to be a valid mean for direct long-term field measurements of arm and trunk inclinations when analysed by the Acti4 customised software.

  16. Ergonomically neutral arm support system

    DOEpatents

    Siminovitch, Michael J; Chung, Jeffrey Y; Dellinges, Steven; Lafever, Robin E

    2005-08-02

    An ergonomic arm support system maintains a neutral position for the forearm. A mechanical support structure attached to a chair or other mounting structure supports the arms of a sitting or standing person. The system includes moving elements and tensioning elements to provide a dynamic balancing force against the forearms. The support structure is not fixed or locked in a rigid position, but is an active dynamic system that is maintained in equipoise by the continuous operation of the opposing forces. The support structure includes an armrest connected to a flexible linkage or articulated or pivoting assembly, which includes a tensioning element such as a spring. The pivoting assembly moves up and down, with the tensioning element providing the upward force that balances the downward force of the arm.

  17. Imprints to the terrestrial environment at galactic arm crossings of the solar system

    NASA Astrophysics Data System (ADS)

    Fahr, H. J.; Fichtner, H.; Scherer, K.; Stawicki, O.

    At its itinerary through our milky way galaxy the solar system moves through highly variable interstellar environments. Due to its orbital revolution around the galactic center, the solar system also crosses periodically the spiral arms of our galactic plane and thereby expe riences pronounced enviromental changes. Gas densities, magnetic fields and galactic cosmic ray intensities are substantially higher there compared to interarm conditions. Here we present theoretical calculations describing the SN-averaged galactic cosmic ray spectrum for regions inside and outside of galactic arms which then allow to predict how periodic passages of the solar system through galactic arms should be reflected by enhanced particle irradiations of the earth`s atmosphere and by correlated terrestrial Be-10 production rates.

  18. A dynamic model for generating actuator specifications for small arms barrel active stabilization

    NASA Astrophysics Data System (ADS)

    Pathak, Anupam; Brei, Diann; Luntz, Jonathan; Lavigna, Chris

    2006-03-01

    Due to stresses encountered in combat, it is known that soldier marksmanship noticeably decreases regardless of prior training. Active stabilization systems in small arms have potential to address this problem to increase soldier survivability and mission effectiveness. The key to success is proper actuator design, but this is highly dependent on proper specification which is challenging due to the human/weapon interaction. This paper presents a generic analytical dynamic model which is capable of defining the necessary actuation specifications for a wide range of small arms platforms. The model is unique because it captures the human interface--shoulder and arm--that introduces the jitter disturbance in addition to the geometry, inertial properties and active stabilization stiffness of the small arms platform. Because no data to date is available for actual shooter-induced disturbance in field conditions, a method is given using the model to back-solve from measured shooting range variability data the disturbance amplitude information relative to the input source (arm or shoulder). As examples of the applicability of the model to various small arms systems, two different weapon systems were investigated: the M24 sniper weapon and the M16 assault rifle. In both cases, model based simulations provided valuable insight into impact on the actuation specifications (force, displacement, phase, frequency) due to the interplay of the human-weapon-active stabilization interface including the effect of shooter-disturbance frequency, disturbance location (shoulder vs. arm), and system parameters (stiffness, barrel rotation).

  19. A brain-computer interface based cognitive training system for healthy elderly: a randomized control pilot study for usability and preliminary efficacy.

    PubMed

    Lee, Tih-Shih; Goh, Siau Juinn Alexa; Quek, Shin Yi; Phillips, Rachel; Guan, Cuntai; Cheung, Yin Bun; Feng, Lei; Teng, Stephanie Sze Wei; Wang, Chuan Chu; Chin, Zheng Yang; Zhang, Haihong; Ng, Tze Pin; Lee, Jimmy; Keefe, Richard; Krishnan, K Ranga Rama

    2013-01-01

    Cognitive decline in aging is a pressing issue associated with significant healthcare costs and deterioration in quality of life. Previously, we reported the successful use of a novel brain-computer interface (BCI) training system in improving symptoms of attention deficit hyperactivity disorder. Here, we examine the feasibility of the BCI system with a new game that incorporates memory training in improving memory and attention in a pilot sample of healthy elderly. This study investigates the safety, usability and acceptability of our BCI system to elderly, and obtains an efficacy estimate to warrant a phase III trial. Thirty-one healthy elderly were randomized into intervention (n = 15) and waitlist control arms (n = 16). Intervention consisted of an 8-week training comprising 24 half-hour sessions. A usability and acceptability questionnaire was administered at the end of training. Safety was investigated by querying users about adverse events after every session. Efficacy of the system was measured by the change of total score from the Repeatable Battery for the Assessment of Neuropsychological Status (RBANS) before and after training. Feedback on the usability and acceptability questionnaire was positive. No adverse events were reported for all participants across all sessions. Though the median difference in the RBANS change scores between arms was not statistically significant, an effect size of 0.6SD was obtained, which reflects potential clinical utility according to Simon's randomized phase II trial design. Pooled data from both arms also showed that the median change in total scores pre and post-training was statistically significant (Mdn = 4.0; p<0.001). Specifically, there were significant improvements in immediate memory (p = 0.038), visuospatial/constructional (p = 0.014), attention (p = 0.039), and delayed memory (p<0.001) scores. Our BCI-based system shows promise in improving memory and attention in healthy elderly, and appears to be safe, user-friendly and acceptable to senior users. Given the efficacy signal, a phase III trial is warranted. ClinicalTrials.gov NCT01661894.

  20. 48 CFR 908.7111 - Arms and ammunition.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 5 2014-10-01 2014-10-01 false Arms and ammunition. 908... ACQUISITION PLANNING REQUIRED SOURCES OF SUPPLIES AND SERVICES Acquisition of Special Items 908.7111 Arms and ammunition. Pursuant to 10 U.S.C. 4655, the Secretary of the Army is authorized to furnish arms, suitable...

  1. 48 CFR 908.7111 - Arms and ammunition.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 5 2011-10-01 2011-10-01 false Arms and ammunition. 908... ACQUISITION PLANNING REQUIRED SOURCES OF SUPPLIES AND SERVICES Acquisition of Special Items 908.7111 Arms and ammunition. Pursuant to 10 U.S.C. 4655, the Secretary of the Army is authorized to furnish arms, suitable...

  2. 48 CFR 908.7111 - Arms and ammunition.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 5 2013-10-01 2013-10-01 false Arms and ammunition. 908... ACQUISITION PLANNING REQUIRED SOURCES OF SUPPLIES AND SERVICES Acquisition of Special Items 908.7111 Arms and ammunition. Pursuant to 10 U.S.C. 4655, the Secretary of the Army is authorized to furnish arms, suitable...

  3. 48 CFR 908.7111 - Arms and ammunition.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 5 2012-10-01 2012-10-01 false Arms and ammunition. 908... ACQUISITION PLANNING REQUIRED SOURCES OF SUPPLIES AND SERVICES Acquisition of Special Items 908.7111 Arms and ammunition. Pursuant to 10 U.S.C. 4655, the Secretary of the Army is authorized to furnish arms, suitable...

  4. Lunar construction utility vehicle

    NASA Technical Reports Server (NTRS)

    1989-01-01

    The lunar construction utility vehicle (LCUV) is an all-purpose construction vehicle which will aid in the robotic assembly of a lunar outpost. The LCUV will have the following capabilities: (1) must be self supporting including repairs; (2) must offload itself from a lunar lander; (3) must be telerobotic and semi-autonomous; (4) must be able to transport one space station common module; (5) must allow for man-rated operation; and (6) must be able to move lunar regolith for site preparation. This study recommends the use of an elastic tracked vehicle. Detailed material analyses of most of the LCUV components were accomplished. The body frame, made of pinned truss elements, was stress analyzed using NASTRAN. A track connection system was developed; however, kinematic and stress analyses are still required. This design recommends the use of hydrogen-oxygen fuel cells for power. Thermal control has proven to be a problem which may be the most challenging technically. A tentative solution has been proposed which utilizes an onboard and towable radiator. Detailed study of the heat dissipation requirements is needed to finalize radiator sizing. Preliminary work on a man-rated cabin has begun; however, this is not required during the first mission phase of the LCUV. Finally, still in the conceptual phases, are the communication, navigation and mechanical arm systems.

  5. Measurement of Galactic Logarithmic Spiral Arm Pitch Angle Using Two-dimensional Fast Fourier Transform Decomposition

    NASA Astrophysics Data System (ADS)

    Davis, Benjamin L.; Berrier, Joel C.; Shields, Douglas W.; Kennefick, Julia; Kennefick, Daniel; Seigar, Marc S.; Lacy, Claud H. S.; Puerari, Ivânio

    2012-04-01

    A logarithmic spiral is a prominent feature appearing in a majority of observed galaxies. This feature has long been associated with the traditional Hubble classification scheme, but historical quotes of pitch angle of spiral galaxies have been almost exclusively qualitative. We have developed a methodology, utilizing two-dimensional fast Fourier transformations of images of spiral galaxies, in order to isolate and measure the pitch angles of their spiral arms. Our technique provides a quantitative way to measure this morphological feature. This will allow comparison of spiral galaxy pitch angle to other galactic parameters and test spiral arm genesis theories. In this work, we detail our image processing and analysis of spiral galaxy images and discuss the robustness of our analysis techniques.

  6. Anomaly and signature filtering improve classifier performance for detection of suspicious access to EHRs.

    PubMed

    Kim, Jihoon; Grillo, Janice M; Boxwala, Aziz A; Jiang, Xiaoqian; Mandelbaum, Rose B; Patel, Bhakti A; Mikels, Debra; Vinterbo, Staal A; Ohno-Machado, Lucila

    2011-01-01

    Our objective is to facilitate semi-automated detection of suspicious access to EHRs. Previously we have shown that a machine learning method can play a role in identifying potentially inappropriate access to EHRs. However, the problem of sampling informative instances to build a classifier still remained. We developed an integrated filtering method leveraging both anomaly detection based on symbolic clustering and signature detection, a rule-based technique. We applied the integrated filtering to 25.5 million access records in an intervention arm, and compared this with 8.6 million access records in a control arm where no filtering was applied. On the training set with cross-validation, the AUC was 0.960 in the control arm and 0.998 in the intervention arm. The difference in false negative rates on the independent test set was significant, P=1.6×10(-6). Our study suggests that utilization of integrated filtering strategies to facilitate the construction of classifiers can be helpful.

  7. Anomaly and Signature Filtering Improve Classifier Performance For Detection Of Suspicious Access To EHRs

    PubMed Central

    Kim, Jihoon; Grillo, Janice M; Boxwala, Aziz A; Jiang, Xiaoqian; Mandelbaum, Rose B; Patel, Bhakti A; Mikels, Debra; Vinterbo, Staal A; Ohno-Machado, Lucila

    2011-01-01

    Our objective is to facilitate semi-automated detection of suspicious access to EHRs. Previously we have shown that a machine learning method can play a role in identifying potentially inappropriate access to EHRs. However, the problem of sampling informative instances to build a classifier still remained. We developed an integrated filtering method leveraging both anomaly detection based on symbolic clustering and signature detection, a rule-based technique. We applied the integrated filtering to 25.5 million access records in an intervention arm, and compared this with 8.6 million access records in a control arm where no filtering was applied. On the training set with cross-validation, the AUC was 0.960 in the control arm and 0.998 in the intervention arm. The difference in false negative rates on the independent test set was significant, P=1.6×10−6. Our study suggests that utilization of integrated filtering strategies to facilitate the construction of classifiers can be helpful. PMID:22195129

  8. Precision liquid level sensor

    DOEpatents

    Field, Michael E.; Sullivan, William H.

    1985-01-01

    A precision liquid level sensor utilizes a balanced R. F. bridge, each arm including an air dielectric line. Changes in liquid level along one air dielectric line imbalance the bridge and create a voltage which is directly measurable across the bridge.

  9. An Inverse Optimal Control Approach to Explain Human Arm Reaching Control Based on Multiple Internal Models.

    PubMed

    Oguz, Ozgur S; Zhou, Zhehua; Glasauer, Stefan; Wollherr, Dirk

    2018-04-03

    Human motor control is highly efficient in generating accurate and appropriate motor behavior for a multitude of tasks. This paper examines how kinematic and dynamic properties of the musculoskeletal system are controlled to achieve such efficiency. Even though recent studies have shown that the human motor control relies on multiple models, how the central nervous system (CNS) controls this combination is not fully addressed. In this study, we utilize an Inverse Optimal Control (IOC) framework in order to find the combination of those internal models and how this combination changes for different reaching tasks. We conducted an experiment where participants executed a comprehensive set of free-space reaching motions. The results show that there is a trade-off between kinematics and dynamics based controllers depending on the reaching task. In addition, this trade-off depends on the initial and final arm configurations, which in turn affect the musculoskeletal load to be controlled. Given this insight, we further provide a discomfort metric to demonstrate its influence on the contribution of different inverse internal models. This formulation together with our analysis not only support the multiple internal models (MIMs) hypothesis but also suggest a hierarchical framework for the control of human reaching motions by the CNS.

  10. Avoiding space robot collisions utilizing the NASA/GSFC tri-mode skin sensor

    NASA Technical Reports Server (NTRS)

    Prinz, F. B.

    1991-01-01

    Sensor based robot motion planning research has primarily focused on mobile robots. Consider, however, the case of a robot manipulator expected to operate autonomously in a dynamic environment where unexpected collisions can occur with many parts of the robot. Only a sensor based system capable of generating collision free paths would be acceptable in such situations. Recently, work in this area has been reported in which a deterministic solution for 2DOF systems has been generated. The arm was sensitized with 'skin' of infra-red sensors. We have proposed a heuristic (potential field based) methodology for redundant robots with large DOF's. The key concepts are solving the path planning problem by cooperating global and local planning modules, the use of complete information from the sensors and partial (but appropriate) information from a world model, representation of objects with hyper-ellipsoids in the world model, and the use of variational planning. We intend to sensitize the robot arm with a 'skin' of capacitive proximity sensors. These sensors were developed at NASA, and are exceptionally suited for the space application. In the first part of the report, we discuss the development and modeling of the capacitive proximity sensor. In the second part we discuss the motion planning algorithm.

  11. Near-Earth Asteroid Retrieval Mission (ARM) Study

    NASA Technical Reports Server (NTRS)

    Brophy, John R.; Muirhead, Brian

    2013-01-01

    The Asteroid Redirect Mission (ARM) concept brings together the capabilities of the science, technology, and the human exploration communities on a grand challenge combining robotic and human space exploration beyond low Earth orbit. This paper addresses the key aspects of this concept and the options studied to assess its technical feasibility. Included are evaluations of the expected number of potential targets, their expected discovery rate, the necessity to adequately characterize candidate mission targets, the process to capture a non-cooperative asteroid in deep space, and the power and propulsion technology required for transportation back to the Earth-Moon system. Viable options for spacecraft and mission designs are developed. Orbits for storing the retrieved asteroid that are stable for more than a hundred years, yet allow for human exploration and commercial utilization of a redirected asteroid, are identified. The study concludes that the key aspects of finding, capturing and redirecting an entire small, near-Earth asteroid to the Earth-Moon system by the first half of the next decade are technically feasible. The study was conducted from January 2013 through March 2013 by the Jet Propulsion Laboratory (JPL) in collaboration with Glenn Research Center (GRC), Johnson Space Center (JSC), Langley Research Center (LaRC), and Marshall Space Flight Center (MSFC).

  12. Development of a model osseo-magnetic link for intuitive rotational control of upper-limb prostheses.

    PubMed

    Rouse, Elliott J; Nahlik, David C; Peshkin, Michael A; Kuiken, Todd A

    2011-04-01

    The lack of proprioceptive feedback is a serious deficiency of current prosthetic control systems. The Osseo-Magnetic Link (OML) is a novel humeral or wrist rotation control system that could preserve proprioception. It utilizes a magnet implanted within the residual bone and sensors mounted in the prosthetic socket to detect magnetic field vectors and determine the bone's orientation. This allows the use of volitional bone rotation to control a prosthetic rotator. We evaluated the performance of the OML using a physical model of a transhumeral residual limb. A small Neodymium-Iron-Boron magnet was placed in a model humerus, inside a model upper arm. Four three-axis Hall-effect sensors were mounted on a ring 3 cm distal to the magnet. An optimization algorithm based on Newton's method determined the position and orientation of the magnet within the model humerus under various conditions, including bone translations, interference, and magnet misalignment. The orientation of the model humerus was determined within 3° for rotations centered in the arm; an additional 6° error was found for translations 20 mm from center. Adjustments in sensor placement may reduce these errors. The results demonstrate that the OML is a feasible solution for providing prosthesis rotation control while preserving rotational proprioception.

  13. Peginterferon alfa-2b in the treatment of Chinese patients with HBeAg-positive chronic hepatitis B: a randomized trial.

    PubMed

    Cheng, Jun; Wang, Yuming; Hou, Jinlin; Luo, Duande; Xie, Qing; Ning, Qin; Ren, Hong; Ding, Huiguo; Sheng, Jifang; Wei, Lai; Chen, Shijun; Fan, Xiaoling; Huang, Wenxiang; Pan, Chen; Gao, Zhiliang; Zhang, Jiming; Zhou, Boping; Chen, Guofeng; Wan, Mobin; Tang, Hong; Wang, Guiqiang; Yang, Yuxiu; Mohamed, Rosmawati; Guan, Richard; Lee, Tzong-Hsi; Chang, Wen-Hsiung; Zhenfei, Huang; Ye, Zhang; Xu, Daozhen

    2014-12-01

    In mainland China, peginterferon (PEG-IFN) alfa-2b 1.0μg/kg/wk for 24 weeks is the approved treatment for HBeAg-positive chronic hepatitis B. This multicenter, randomized trial evaluated the safety and efficacy of regimens utilizing increased dose or treatment duration in treatment-naive Chinese patients with chronic hepatitis B. 670 HBeAg-positive patients from China, Malaysia, Taiwan area, Singapore, and Thailand were enrolled. Patients received PEG-IFN alfa-2b 1.0μg/kg/wk (arm A) or 1.5μg/kg/wk (arm B) for 24 weeks, or 1.5μg/kg/wk for 48 weeks (arm C). The primary end point was loss of HBeAg 24 weeks after end of treatment. At the end of follow-up, HBeAg loss was significantly greater in arm C compared with arm A (31.3% vs. 17.3%; P=0.001) and arm B (31.3% vs. 18.1%; P=0.001). No significant difference in the rate of HBeAg loss was observed between arms A and B. The proportions of patients with HBe seroconversion, HBV DNA levels <20,000IU/mL, and ALT normalization at the end of follow-up were significantly higher in arm C compared with arm A and arm B. In arms A, B, and C, rates of early treatment discontinuation were 6.3%, 4.9%, and 8.9%; of discontinuation due to an AE, 2%, 3%, and 3%; and of AEs requiring dose modification, 3%, 6%, and 10%, respectively. In Chinese patients with HBeAg-positive chronic hepatitis B, PEG-IFN alfa-2b 1.5μg/kg/wk for 48 weeks is more efficacious compared with 1.0 and 1.5μg/kg/wk for 24 weeks. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.

  14. Obstructive sleep apnea and associated attrition, active component, U.S. Armed Forces, January 2004-May 2016.

    PubMed

    Rogers, Amy E; Stahlman, Shauna; Hunt, Devin J; Oh, Gi-Taik; Clark, Leslie L

    2016-10-01

    Obstructive sleep apnea (OSA) is a growing health concern in both civilian and military populations. Individuals who suffer from OSA have increased rates of cardiovascular disease, chronic fatigue, motor vehicle accidents, cognitive impairment, and post-traumatic stress disorder. Data from the Defense Medical Surveillance System (DMSS) were utilized to examine the incidence of OSA and associated attrition from service in active component military members from 1 January 2004 through 31 May 2016. The study identified 223,731 incident cases of OSA with an overall incidence rate of 139.2 per 10,000 person-years, between 2004 and 2015. Rates increased more than 3-fold between 2004 and 2015. In 2015, 48.1% of all incident cases of OSA were diagnosed in the last year of service. The high percentage of cases diagnosed prior to separation from service is concerning because OSA is a treatable and partially preventable disease. OSA represents a large health and economic burden for the armed services and yet there are persistent research gaps in appropriate screening and prevention strategies to improve both individual health and mission performance.

  15. Performance measurements of a dual-rotor arm mechanism for efficient flight transition of fixed-wing unmanned aerial vehicles

    NASA Astrophysics Data System (ADS)

    McGill, Karen Ashley Jean

    Reconfigurable systems are a class of systems that can be transformed into different configurations, generally to perform unique functions or to maintain operational efficiency under distinct conditions. A UAV can be considered a reconfigurable system when coupled with various useful features such as vertical take-off and landing (VTOL), hover capability, long-range, and relatively large payload. Currently, a UAV having these capabilities is being designed by the UTSA Mechanical Engineering department. UAVs such as this one have the following potential uses: emergency response/disaster relief, hazard-critical missions, offshore oil rig/wind farm delivery, surveillance, etc. The goal of this thesis is to perform experimental thrust and power measurements for the propulsion system of this fixed-wing UAV. Focus was placed on a rotating truss arm supporting two brushless motors and rotors that will later be integrated to the ends of the UAV wing. These truss arms will rotate via a supporting shaft from 0° to 90° to transition the UAV between a vertical take-off, hover, and forward flight. To make this hover/transition possible, a relationship between thrust, arm angle, and power drawn was established by testing the performance of the arm/motor assembly at arm angles of 0°, 15°, 30°, 45°, 60°, 75°, and 90°. Universal equations for this system of thrust as a function of the arm angle were created by correlating data collected by a load cell. A Solidworks model was created and used to conduct fluid dynamics simulations of the streamlines over the arm/motor assembly.

  16. Consequences of impact on arm (elbow and shoulder joints) caused by ball hitting, theoretical analysis

    NASA Astrophysics Data System (ADS)

    Negrea, Adina; Busuioceanu, Ioana Iuliana

    2018-02-01

    Present paper estimates the mechanics of the impact of a ball and a hand-arm, during the sports training using a classical model for the hand-arm system, avoiding the contribution of the coefficient of restitution. The results of this investigation are focused on the equations needed to find out theimpact reactions in elbow and shoulder joints, for different anthropometric data. Also, the computing of the position of mass centers and the moments of inertia for each constitutive part of hand-arm system is made.

  17. Online geometrical calibration of a mobile C-arm using external sensors

    NASA Astrophysics Data System (ADS)

    Mitschke, Matthias M.; Navab, Nassir; Schuetz, Oliver

    2000-04-01

    3D tomographic reconstruction of high contrast objects such as contrast agent enhanced blood vessels or bones from x-ray images acquired by isocentric C-arm systems recently gained interest. For tomographic reconstruction, a sequence of images is captured during the C-arm rotation around the patient and the precise projection geometry has to be determined for each image. This is a difficult task, as C- arms usually do not provide accurate information about their projection geometry. Standard methods propose the use of an x-ray calibration phantom and an offline calibration, when the motion of the C-arm is supposed to be reproducible between calibration and patient run. However, mobile C-arms usually do not have this desirable property. Therefore, an online recovery of projection geometry is necessary. Here, we study the use of external tracking systems such as Polaris or Optotrak from Northern Digital, Inc., for online calibration. In order to use the external tracking system for recovery of x-ray projection geometry two unknown transformations have to be estimated. We describe our attempt to solve this calibration problem. These are the relations between x-ray imaging system and marker plate of the tracking system as well as worked and sensor coordinate system. Experimental result son anatomical data are presented and visually compared with the results of estimating the projection geometry with an x-ray calibration phantom.

  18. A common neural element receiving rhythmic arm and leg activity as assessed by reflex modulation in arm muscles.

    PubMed

    Sasada, Syusaku; Tazoe, Toshiki; Nakajima, Tsuyoshi; Futatsubashi, Genki; Ohtsuka, Hiroyuki; Suzuki, Shinya; Zehr, E Paul; Komiyama, Tomoyoshi

    2016-04-01

    Neural interactions between regulatory systems for rhythmic arm and leg movements are an intriguing issue in locomotor neuroscience. Amplitudes of early latency cutaneous reflexes (ELCRs) in stationary arm muscles are modulated during rhythmic leg or arm cycling but not during limb positioning or voluntary contraction. This suggests that interneurons mediating ELCRs to arm muscles integrate outputs from neural systems controlling rhythmic limb movements. Alternatively, outputs could be integrated at the motoneuron and/or supraspinal levels. We examined whether a separate effect on the ELCR pathways and cortico-motoneuronal excitability during arm and leg cycling is integrated by neural elements common to the lumbo-sacral and cervical spinal cord. The subjects performed bilateral leg cycling (LEG), contralateral arm cycling (ARM), and simultaneous contralateral arm and bilateral leg cycling (A&L), while ELCRs in the wrist flexor and shoulder flexor muscles were evoked by superficial radial (SR) nerve stimulation. ELCR amplitudes were facilitated by cycling tasks and were larger during A&L than during ARM and LEG. A low stimulus intensity during ARM or LEG generated a larger ELCR during A&L than the sum of ELCRs during ARM and LEG. We confirmed this nonlinear increase in single motor unit firing probability following SR nerve stimulation during A&L. Furthermore, motor-evoked potentials following transcranial magnetic and electrical stimulation did not show nonlinear potentiation during A&L. These findings suggest the existence of a common neural element of the ELCR reflex pathway that is active only during rhythmic arm and leg movement and receives convergent input from contralateral arms and legs. Copyright © 2016 the American Physiological Society.

  19. The effect of household heads training about the use of treated bed nets on the burden of malaria and anaemia in under-five children: a cluster randomized trial in Ethiopia.

    PubMed

    Deribew, Amare; Birhanu, Zewdie; Sena, Lelisa; Dejene, Tariku; Reda, Ayalu A; Sudhakar, Morankar; Alemseged, Fessehaye; Tessema, Fasil; Zeynudin, Ahmed; Biadgilign, Sibhatu; Deribe, Kebede

    2012-01-06

    Long-lasting insecticide-treated bed nets (LLITN) have demonstrated a significant effect in reducing malaria-related morbidity and mortality. However, barriers on the utilization of LLITN have hampered the desired outcomes. The aim of this study was to assess the effect of community empowerment on the burden of malaria and anaemia in under-five children in Ethiopia. A cluster randomized trial was done in 22 (11 intervention and 11 control) villages in south-west Ethiopia. The intervention consisted of tailored training of household heads about the proper use of LLITN and community network system. The burden of malaria and anaemia in under-five children was determined through mass blood investigation at baseline, six and 12 months of the project period. Cases of malaria and anaemia were treated based on the national protocol. The burden of malaria and anaemia between the intervention and control villages was compared using the complex logistic regression model by taking into account the clustering effect. Eight Focus group discussions were conducted to complement the quantitative findings. A total of 2,105 household heads received the intervention and the prevalence of malaria and anaemia was assessed among 2410, 2037 and 2612 under-five children at baseline, six and 12 months of the project period respectively. During the high transmission/epidemic season, children in the intervention arm were less likely to have malaria as compared to children in the control arm (OR = 0.42; 95%CI: 0.32, 0.57). Symptomatic malaria also steadily declined in the intervention villages compared to the control villages in the follow up periods. Children in the intervention arm were less likely to be anaemic compared to those in the control arm both at the high (OR = 0.84; 95%CI: 0.71, 0.99)) and low (OR = 0.73; 95%CI: 0.60, 0.89) transmission seasons. Training of household heads on the utilization of LLITN significantly reduces the burden of malaria in under-five children. The Ministry of Health of Ethiopia in collaboration with other partners should design similar strategies in high-risk areas to control malaria in Ethiopia. Australia and New Zealand Clinical Trials Register (ANZCTR): ACTRN12610000035022.

  20. 49 CFR 236.22 - Semaphore signal arm; clearance to other objects.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Semaphore signal arm; clearance to other objects... Rules and Instructions: All Systems Roadway Signals and Cab Signals § 236.22 Semaphore signal arm; clearance to other objects. At least one-half inch clearance shall be provided between semaphore signal arm...

  1. 48 CFR 552.237-72 - Prohibition Regarding “Quasi-Military Armed Forces.”

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...Quasi-Military Armed Forces.â 552.237-72 Section 552.237-72 Federal Acquisition Regulations System... Provisions and Clauses 552.237-72 Prohibition Regarding “Quasi-Military Armed Forces.” As prescribed in 537.110(b), insert the following clause: Prohibition Regarding “Quasi-Military Armed Forces” (SEP 1999...

  2. 49 CFR 236.22 - Semaphore signal arm; clearance to other objects.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Semaphore signal arm; clearance to other objects... Rules and Instructions: All Systems Roadway Signals and Cab Signals § 236.22 Semaphore signal arm; clearance to other objects. At least one-half inch clearance shall be provided between semaphore signal arm...

  3. 48 CFR 225.7702 - Acquisition of small arms.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 3 2012-10-01 2012-10-01 false Acquisition of small arms... Operations in Iraq or Afghanistan 225.7702 Acquisition of small arms. (a) Except as provided in paragraph (b) of this section, when acquiring small arms for assistance to the Army of Iraq, the Army of...

  4. 49 CFR 236.22 - Semaphore signal arm; clearance to other objects.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Semaphore signal arm; clearance to other objects... Rules and Instructions: All Systems Roadway Signals and Cab Signals § 236.22 Semaphore signal arm; clearance to other objects. At least one-half inch clearance shall be provided between semaphore signal arm...

  5. 48 CFR 225.7702-1 - Acquisition of small arms.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 3 2014-10-01 2014-10-01 false Acquisition of small arms... Operations in Afghanistan 225.7702-1 Acquisition of small arms. (a) Except as provided in paragraph (b) of this section, when acquiring small arms for assistance to the Army of Afghanistan, the Afghani Police...

  6. 48 CFR 225.7702 - Acquisition of small arms.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Acquisition of small arms... Operations in Iraq or Afghanistan 225.7702 Acquisition of small arms. (a) Except as provided in paragraph (b) of this section, when acquiring small arms for assistance to the Army of Iraq, the Army of...

  7. 49 CFR 236.22 - Semaphore signal arm; clearance to other objects.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Semaphore signal arm; clearance to other objects... Rules and Instructions: All Systems Roadway Signals and Cab Signals § 236.22 Semaphore signal arm; clearance to other objects. At least one-half inch clearance shall be provided between semaphore signal arm...

  8. 49 CFR 236.22 - Semaphore signal arm; clearance to other objects.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Semaphore signal arm; clearance to other objects... Rules and Instructions: All Systems Roadway Signals and Cab Signals § 236.22 Semaphore signal arm; clearance to other objects. At least one-half inch clearance shall be provided between semaphore signal arm...

  9. 48 CFR 225.7702-1 - Acquisition of small arms.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 3 2013-10-01 2013-10-01 false Acquisition of small arms... Operations in Afghanistan 225.7702-1 Acquisition of small arms. (a) Except as provided in paragraph (b) of this section, when acquiring small arms for assistance to the Army of Afghanistan, the Afghani Police...

  10. 48 CFR 225.7702 - Acquisition of small arms.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 3 2011-10-01 2011-10-01 false Acquisition of small arms... Operations in Iraq or Afghanistan 225.7702 Acquisition of small arms. (a) Except as provided in paragraph (b) of this section, when acquiring small arms for assistance to the Army of Iraq, the Army of...

  11. Surface Energy Balance System (SEBS) Handbook

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cook, D. R.

    2016-01-01

    A Surface Energy Balance System (SEBS) has been installed collocated with each deployed Eddy Correlation Flux Measurement System (ECOR) at the Atmospheric Radiation Measurement (ARM) Climate Research Facility’s Southern Great Plains (SGP) site, North Slope of Alaska (NSA) site, first ARM Mobile Facility (AMF1), second ARM Mobile Facility (AMF2), and third ARM Mobile Facility (AMF3) at Oliktok Point (OLI). A SEBS was also deployed with the Tropical Western Pacific (TWP) site, before it was decommissioned. Data from these sites, including the retired TWP, are available in the ARM Data Archive. The SEBS consists of upwelling and downwelling solar and infraredmore » radiometers within one net radiometer, a wetness sensor, and soil measurements. The SEBS measurements allow the comparison of ECOR sensible and latent heat fluxes with the energy balance determined from the SEBS and provide information on wetting of the sensors for data quality purposes.« less

  12. New nonlinear control algorithms for multiple robot arms

    NASA Technical Reports Server (NTRS)

    Tarn, T. J.; Bejczy, A. K.; Yun, X.

    1988-01-01

    Multiple coordinated robot arms are modeled by considering the arms as closed kinematic chains and as a force-constrained mechanical system working on the same object simultaneously. In both formulations, a novel dynamic control method is discussed. It is based on feedback linearization and simultaneous output decoupling technique. By applying a nonlinear feedback and a nonlinear coordinate transformation, the complicated model of the multiple robot arms in either formulation is converted into a linear and output decoupled system. The linear system control theory and optimal control theory are used to design robust controllers in the task space. The first formulation has the advantage of automatically handling the coordination and load distribution among the robot arms. In the second formulation, it was found that by choosing a general output equation it became possible simultaneously to superimpose the position and velocity error feedback with the force-torque error feedback in the task space.

  13. Multibody Simulation Software Testbed for Small-Body Exploration and Sampling

    NASA Technical Reports Server (NTRS)

    Acikmese, Behcet; Blackmore, James C.; Mandic, Milan

    2011-01-01

    G-TAG is a software tool for the multibody simulation of a spacecraft with a robotic arm and a sampling mechanism, which performs a touch-and-go (TAG) maneuver for sampling from the surface of a small celestial body. G-TAG utilizes G-DYN, a multi-body simulation engine described in the previous article, and interfaces to controllers, estimators, and environmental forces that affect the spacecraft. G-TAG can easily be adapted for the analysis of the mission stress cases to support the design of a TAG system, as well as for comprehensive Monte Carlo simulations to analyze and evaluate a particular TAG system design. Any future small-body mission will benefit from using G-TAG, which has already been extensively used in Comet Odyssey and Galahad Asteroid New Frontiers proposals.

  14. Reduced-dose C-arm computed tomography applications at a pediatric institution.

    PubMed

    Acord, Michael; Shellikeri, Sphoorti; Vatsky, Seth; Srinivasan, Abhay; Krishnamurthy, Ganesh; Keller, Marc S; Cahill, Anne Marie

    2017-12-01

    Reduced-dose C-arm computed tomography (CT) uses flat-panel detectors to acquire real-time 3-D images in the interventional radiology suite to assist with anatomical localization and procedure planning. To describe dose-reduction techniques for C-arm CT at a pediatric institution and to provide guidance for implementation. We conducted a 5-year retrospective study on procedures using an institution-specific reduced-dose protocol: 5 or 8 s Dyna Rotation, 248/396 projection images/acquisition and 0.1-0.17 μGy/projection dose at the detector with 0.3/0.6/0.9-mm copper (Cu) filtration. We categorized cases by procedure type and average patient age and calculated C-arm CT and total dose area product (DAP). Two hundred twenty-two C-arm CT-guided procedures were performed with a dose-reduction protocol. The most common procedures were temporomandibular and sacroiliac joint injections (48.6%) and sclerotherapy (34.2%). C-arm CT was utilized in cases of difficult percutaneous access in less common applications such as cecostomy and gastrostomy placement, foreign body retrieval and thoracentesis. C-arm CT accounted for between 9.9% and 80.7% of the total procedural DAP. Dose-reducing techniques can preserve image quality for intervention while reducing radiation exposure to the child. This technology has multiple applications within pediatric interventional radiology and can be considered as an adjunctive imaging tool in a variety of procedures, particularly when percutaneous access is challenging despite routine fluoroscopic or ultrasound guidance.

  15. Trial Development of a Mobile Feeding Assistive Robotic Arm for People with Physical Disabilities of the Extremities

    NASA Astrophysics Data System (ADS)

    Uehara, Hideyuki; Higa, Hiroki; Soken, Takashi; Namihira, Yoshinori

    A mobile feeding assistive robotic arm for people with physical disabilities of the extremities has been developed in this paper. This system is composed of a robotic arm, microcontroller, and its interface. The main unit of the robotic arm can be contained in a laptop computer's briefcase. Its weight is 5kg, including two 12-V lead acid rechargeable batteries. This robotic arm can be also mounted on a wheelchair. To verify performance of the mobile robotic arm system, drinking tea task was experimentally performed by two able-bodied subjects as well as three persons suffering from muscular dystrophy. From the experimental results, it was clear that they could smoothly carry out the drinking task, and that the robotic arm could firmly grasp a commercially available 500-ml plastic bottle. The eating task was also performed by the two able-bodied subjects. The experimental results showed that they could eat porridge by using a spoon without any difficulty.

  16. Thermal Nondestructive Evaluation Report: Inspection of the Refurbished Manipulator Arm System in the Manipulator Development Facility at Johnson Space Center 10-12 January 2001

    NASA Technical Reports Server (NTRS)

    Cramer, K. Elliott

    2002-01-01

    On 4 December 2002, a failure of the Refurbished Manipulator Arm System (RMAS) occurred in the Manipulator Development Facility (MDF) at Johnson Space Center. When the Test Director commanded a should pitch maneuver to lift the arm from its payload bay pedestal, the yaw controls failed. This, coupled with a gravitational forces (due to the angle of the shoulder joint with respect to vertical), resulted in uncontrolled arm motion. The shoulder yaw joint moved approximately 20 degrees, causing the extended arm to strike and severely damage the port side MDF catwalk handrails. The arm motion stopped after impact with the handrails. On 10-12 January 2001, inspections were performed on the port face of the lower and upper arms of the RMAS using a infrared thermography developed at Langley Research Center. This paper presents the results of those nondestructive inspections and provides a complete description of the anomalies found and their locations.

  17. 41 CFR 102-33.430 - Who must report Federal aircraft cost and utilization data?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...? Executive agencies, except the Armed Forces and U.S. intelligence agencies, must report Federal cost and... aircraft only if Federal money was expended on the aircraft. Commercial Aviation Services (CAS) Cost and...

  18. Precision liquid level sensor

    DOEpatents

    Field, M.E.; Sullivan, W.H.

    1985-01-29

    A precision liquid level sensor utilizes a balanced R. F. bridge, each arm including an air dielectric line. Changes in liquid level along one air dielectric line imbalance the bridge and create a voltage which is directly measurable across the bridge. 2 figs.

  19. Lunar surface operations. Volume 3: Robotic arm for lunar surface vehicle

    NASA Technical Reports Server (NTRS)

    Shields, William; Feteih, Salah; Hollis, Patrick

    1993-01-01

    A robotic arm for a lunar surface vehicle that can help in handling cargo and equipment, and remove obstacles from the path of the vehicle is defined as a support to NASA's intention to establish a lunar based colony by the year 2010. Its mission would include, but not limited to the following: exploration, lunar sampling, replace and remove equipment, and setup equipment (e.g. microwave repeater stations). Performance objectives for the robotic arm include a reach of 3 m, accuracy of 1 cm, arm mass of 100 kg, and lifting capability of 50 kg. The end effectors must grip various sizes and shapes of cargo; push, pull, turn, lift, or lower various types of equipment; and clear a path on the lunar surface by shoveling, sweeping aside, or gripping the obstacle present in the desired path. The arm can safely complete a task within a reasonable amount of time; the actual time is dependent upon the task to be performed. The positioning of the arm includes a manual backup system such that the arm can be safely stored in case of failure. Remote viewing and proximity and positioning sensors are incorporated in the design of the arm. The following specific topic are addressed in this report: mission and requirements, system design and integration, mechanical structure, modified wrist, structure-to-end-effector interface, end-effectors, and system controls.

  20. Design of mechanisms to lock/latch systems under rotational or translational motion

    NASA Technical Reports Server (NTRS)

    Billimoria, R. P.

    1976-01-01

    Bodies/systems need to be stopped and locked/latched at the end of their path. Some examples of these systems in the aerospace industry (including launch vehicle, spacecraft, and the ground support equipment) are the command module access arm, service arms, docking module of the ASTP and the orbiter access arm for the space shuttle. Two major aspects are covered: (1) various methods of latching and (2) selection of the optimum method for latching, depending on the application and the design requirement criteria.

  1. Control of octopus arm extension by a peripheral motor program.

    PubMed

    Sumbre, G; Gutfreund, Y; Fiorito, G; Flash, T; Hochner, B

    2001-09-07

    For goal-directed arm movements, the nervous system generates a sequence of motor commands that bring the arm toward the target. Control of the octopus arm is especially complex because the arm can be moved in any direction, with a virtually infinite number of degrees of freedom. Here we show that arm extensions can be evoked mechanically or electrically in arms whose connection with the brain has been severed. These extensions show kinematic features that are almost identical to normal behavior, suggesting that the basic motor program for voluntary movement is embedded within the neural circuitry of the arm itself. Such peripheral motor programs represent considerable simplification in the motor control of this highly redundant appendage.

  2. Radiance Research Particle Soot/Absorption Photometer Instrument Handbook

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Springston, S. R.

    2016-03-01

    Radiance Research PSAPs as described in this Handbook are deployed in the second ARM Mobile Facility (AMF2) Aerosol Observing System (AOS), the third ARM Mobile Facility (AMF3) AOS, ENA AOS and Mobile Aerosol Observing System (MAOS)-A. An earlier version of the PSAP is currently operated in the ARM Aerial Facility and at SGP. The older SGP instrument is covered in a separate Handbook.

  3. Local Treatment of Unresectable Colorectal Liver Metastases: Results of a Randomized Phase II Trial

    PubMed Central

    Van Coevorden, Frits; Punt, Cornelis J. A.; Pierie, Jean-Pierre E. N.; Borel-Rinkes, Inne; Ledermann, Jonathan A.; Poston, Graeme; Bechstein, Wolf; Lentz, Marie-Ange; Mauer, Murielle; Folprecht, Gunnar; Van Cutsem, Eric; Ducreux, Michel; Nordlinger, Bernard

    2017-01-01

    Background: Tumor ablation is often employed for unresectable colorectal liver metastases. However, no survival benefit has ever been demonstrated in prospective randomized studies. Here, we investigate the long-term benefits of such an aggressive approach. Methods: In this randomized phase II trial, 119 patients with unresectable colorectal liver metastases (n < 10 and no extrahepatic disease) received systemic treatment alone or systemic treatment plus aggressive local treatment by radiofrequency ablation ± resection. Previously, we reported that the primary end point (30-month overall survival [OS] > 38%) was met. We now report on long-term OS results. All statistical tests were two-sided. The analyses were according to intention to treat. Results: At a median follow up of 9.7 years, 92 of 119 (77.3%) patients had died: 39 of 60 (65.0%) in the combined modality arm and 53 of 59 (89.8%) in the systemic treatment arm. Almost all patients died of progressive disease (35 patients in the combined modality arm, 49 patients in the systemic treatment arm). There was a statistically significant difference in OS in favor of the combined modality arm (hazard ratio [HR] = 0.58, 95% confidence interval [CI] = 0.38 to 0.88, P = .01). Three-, five-, and eight-year OS were 56.9% (95% CI = 43.3% to 68.5%), 43.1% (95% CI = 30.3% to 55.3%), 35.9% (95% CI = 23.8% to 48.2%), respectively, in the combined modality arm and 55.2% (95% CI = 41.6% to 66.9%), 30.3% (95% CI = 19.0% to 42.4%), 8.9% (95% CI = 3.3% to 18.1%), respectively, in the systemic treatment arm. Median OS was 45.6 months (95% CI = 30.3 to 67.8 months) in the combined modality arm vs 40.5 months (95% CI = 27.5 to 47.7 months) in the systemic treatment arm. Conclusions: This phase II trial is the first randomized study demonstrating that aggressive local treatment can prolong OS in patients with unresectable colorectal liver metastases. PMID:28376151

  4. Local Treatment of Unresectable Colorectal Liver Metastases: Results of a Randomized Phase II Trial.

    PubMed

    Ruers, Theo; Van Coevorden, Frits; Punt, Cornelis J A; Pierie, Jean-Pierre E N; Borel-Rinkes, Inne; Ledermann, Jonathan A; Poston, Graeme; Bechstein, Wolf; Lentz, Marie-Ange; Mauer, Murielle; Folprecht, Gunnar; Van Cutsem, Eric; Ducreux, Michel; Nordlinger, Bernard

    2017-09-01

    Tumor ablation is often employed for unresectable colorectal liver metastases. However, no survival benefit has ever been demonstrated in prospective randomized studies. Here, we investigate the long-term benefits of such an aggressive approach. In this randomized phase II trial, 119 patients with unresectable colorectal liver metastases (n < 10 and no extrahepatic disease) received systemic treatment alone or systemic treatment plus aggressive local treatment by radiofrequency ablation ± resection. Previously, we reported that the primary end point (30-month overall survival [OS] > 38%) was met. We now report on long-term OS results. All statistical tests were two-sided. The analyses were according to intention to treat. At a median follow up of 9.7 years, 92 of 119 (77.3%) patients had died: 39 of 60 (65.0%) in the combined modality arm and 53 of 59 (89.8%) in the systemic treatment arm. Almost all patients died of progressive disease (35 patients in the combined modality arm, 49 patients in the systemic treatment arm). There was a statistically significant difference in OS in favor of the combined modality arm (hazard ratio [HR] = 0.58, 95% confidence interval [CI] = 0.38 to 0.88, P = .01). Three-, five-, and eight-year OS were 56.9% (95% CI = 43.3% to 68.5%), 43.1% (95% CI = 30.3% to 55.3%), 35.9% (95% CI = 23.8% to 48.2%), respectively, in the combined modality arm and 55.2% (95% CI = 41.6% to 66.9%), 30.3% (95% CI = 19.0% to 42.4%), 8.9% (95% CI = 3.3% to 18.1%), respectively, in the systemic treatment arm. Median OS was 45.6 months (95% CI = 30.3 to 67.8 months) in the combined modality arm vs 40.5 months (95% CI = 27.5 to 47.7 months) in the systemic treatment arm. This phase II trial is the first randomized study demonstrating that aggressive local treatment can prolong OS in patients with unresectable colorectal liver metastases. © The Author 2017. Published by Oxford University Press.

  5. Technical review of the da Vinci surgical telemanipulator.

    PubMed

    Freschi, C; Ferrari, V; Melfi, F; Ferrari, M; Mosca, F; Cuschieri, A

    2013-12-01

    The da Vinci robotic surgical telemanipulator has been utilized in several surgical specialties for varied procedures, and the users' experiences have been widely published. To date, no detailed system technical analyses have been performed. A detailed review was performed of all publications and patents about the technical aspects of the da Vinci robotic system. Published technical literature on the da Vinci system highlight strengths and weaknesses of the robot design. While the system facilitates complex surgical operations and has a low malfunction rate, the lack of haptic (especially tactile) feedback and collisions between the robotic arms remain the major limitations of the system. Accurate, preplanned positioning of access ports is essential. Knowledge of the technical aspects of the da Vinci robot is important for optimal use. We confirmed the excellent system functionality and ease of use for surgeons without an engineering background. Research and development of the surgical robot has been predominant in the literature. Future trends address robot miniaturization and intelligent control design. Copyright © 2012 John Wiley & Sons, Ltd.

  6. A highly articulated robotic surgical system for minimally invasive surgery.

    PubMed

    Ota, Takeyoshi; Degani, Amir; Schwartzman, David; Zubiate, Brett; McGarvey, Jeremy; Choset, Howie; Zenati, Marco A

    2009-04-01

    We developed a novel, highly articulated robotic surgical system (CardioARM) to enable minimally invasive intrapericardial therapeutic delivery through a subxiphoid approach. We performed preliminary proof of concept studies in a porcine preparation by performing epicardial ablation. CardioARM is a robotic surgical system having an articulated design to provide unlimited but controllable flexibility. The CardioARM consists of serially connected, rigid cyclindrical links housing flexible working ports through which catheter-based tools for therapy and imaging can be advanced. The CardioARM is controlled by a computer-driven, user interface, which is operated outside the operative field. In six experimental subjects, the CardioARM was introduced percutaneously through a subxiphoid access. A commercial 5-French radiofrequency ablation catheter was introduced through the working port, which was then used to guide deployment. In all subjects, regional ("linear") left atrial ablation was successfully achieved without complications. Based on these preliminary studies, we believe that the CardioARM promises to enable deployment of a number of epicardium-based therapies. Improvements in imaging techniques will likely facilitate increasingly complex procedures.

  7. Archetype relational mapping - a practical openEHR persistence solution.

    PubMed

    Wang, Li; Min, Lingtong; Wang, Rui; Lu, Xudong; Duan, Huilong

    2015-11-05

    One of the primary obstacles to the widespread adoption of openEHR methodology is the lack of practical persistence solutions for future-proof electronic health record (EHR) systems as described by the openEHR specifications. This paper presents an archetype relational mapping (ARM) persistence solution for the archetype-based EHR systems to support healthcare delivery in the clinical environment. First, the data requirements of the EHR systems are analysed and organized into archetype-friendly concepts. The Clinical Knowledge Manager (CKM) is queried for matching archetypes; when necessary, new archetypes are developed to reflect concepts that are not encompassed by existing archetypes. Next, a template is designed for each archetype to apply constraints related to the local EHR context. Finally, a set of rules is designed to map the archetypes to data tables and provide data persistence based on the relational database. A comparison study was conducted to investigate the differences among the conventional database of an EHR system from a tertiary Class A hospital in China, the generated ARM database, and the Node + Path database. Five data-retrieving tests were designed based on clinical workflow to retrieve exams and laboratory tests. Additionally, two patient-searching tests were designed to identify patients who satisfy certain criteria. The ARM database achieved better performance than the conventional database in three of the five data-retrieving tests, but was less efficient in the remaining two tests. The time difference of query executions conducted by the ARM database and the conventional database is less than 130 %. The ARM database was approximately 6-50 times more efficient than the conventional database in the patient-searching tests, while the Node + Path database requires far more time than the other two databases to execute both the data-retrieving and the patient-searching tests. The ARM approach is capable of generating relational databases using archetypes and templates for archetype-based EHR systems, thus successfully adapting to changes in data requirements. ARM performance is similar to that of conventionally-designed EHR systems, and can be applied in a practical clinical environment. System components such as ARM can greatly facilitate the adoption of openEHR architecture within EHR systems.

  8. Design of mechanical arm for an automatic sorting system of recyclable cans

    NASA Astrophysics Data System (ADS)

    Resti, Y.; Mohruni, A. S.; Burlian, F.; Yani, I.; Amran, A.

    2018-04-01

    The use of a mechanical arm for an automatic sorting system of used cans should be designed carefully. The right design will result in a high precision sorting rate and a short sorting time. The design includes first; design manipulator,second; determine link and joint specifications, and third; build mechanical systems and control systems. This study aims to design the mechanical arm as a hardware system for automatic cans sorting system. The material used for the manipulator is the aluminum plate. The manipulator is designed using 6 links and 6 join where the 6th link is the end effectorand the 6th join is the gripper. As a driving motor used servo motor, while as a microcontroller used Arduino Uno which is connected with Matlab programming language. Based on testing, a mechanical arm designed for this recyclable canned recycling system has a precision sorting rate at 93%, where the average total time required for sorting is 10.82 seconds.

  9. Dual-Arm Generalized Compliant Motion With Shared Control

    NASA Technical Reports Server (NTRS)

    Backes, Paul G.

    1994-01-01

    Dual-Arm Generalized Compliant Motion (DAGCM) primitive computer program implementing improved unified control scheme for two manipulator arms cooperating in task in which both grasp same object. Provides capabilities for autonomous, teleoperation, and shared control of two robot arms. Unifies cooperative dual-arm control with multi-sensor-based task control and makes complete task-control capability available to higher-level task-planning computer system via large set of input parameters used to describe desired force and position trajectories followed by manipulator arms. Some concepts discussed in "A Generalized-Compliant-Motion Primitive" (NPO-18134).

  10. The RAndomized Placebo Phase Study Of Rilonacept in the Treatment of Systemic Juvenile Idiopathic Arthritis (RAPPORT)

    PubMed Central

    Ilowite, Norman T.; Prather, Kristi; Lokhnygina, Yuliya; Schanberg, Laura E.; Elder, Melissa; Milojevic, Diana; Verbsky, James W.; Spalding, Steven J.; Kimura, Yukiko; Imundo, Lisa F.; Punaro, Marilynn G.; Sherry, David D.; Tarvin, Stacey E.; Zemel, Lawrence S.; Birmingham, James D.; Gottlieb, Beth S.; Miller, Michael L.; O'Neil, Kathleen; Ruth, Natasha M.; Wallace, Carol A.; Singer, Nora G.; Sandborg, Christy I.

    2015-01-01

    Background Interleukin-1 plays a pivotal role in in the pathogenesis of systemic juvenile idiopathic arthritis (sJIA). We assessed the efficacy and safety of rilonacept (IL-1 trap), an IL-1 inhibitor, in a randomized, double-blind, placebo-controlled trial. Methods An initial 4-week double-blind placebo phase was incorporated into a 24-week randomized multi-center design, followed by an open label phase. We randomized 71 children with at least 2 active joints 1:1 to 2 arms of the study. Patients in the rilonacept arm received rilonacept (4.4mg/kg loading dose followed by 2.2mg/kg weekly, subcutaneously) from day 0; patients in the placebo arm received placebo for 4 weeks followed by a loading dose of rilonacept at week 4 followed by weekly maintenance doses. The primary endpoint was time to response, using adapted JIA ACR30 response criteria coupled with absence of fever and taper of systemic corticosteroids using pre-specified criteria. Results Time to response was shorter in the rilonacept arm than in the placebo arm (Chi-square 7.235, P=.007). Secondary analysis showed 20/35 (57%) of patients in the rilonacept arm responded at week 4 compared to 9/33 (27%) in the placebo arm (P=.016) using the same response criteria. Exacerbation of sJIA (4) was the most common SAE. More patients in the rilonacept arm had elevated liver transaminases, including more than three times the upper limits of normal, as compared to those in the placebo arm. Adverse events were similar in the two arms of the study. Conclusions Rilonacept was generally well tolerated and demonstrated efficacy in active sJIA. PMID:24839206

  11. 49 CFR 236.531 - Trip arm; height and distance from rail.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Trip arm; height and distance from rail. 236.531... Train Stop, Train Control and Cab Signal Systems Rules and Instructions; Roadway § 236.531 Trip arm; height and distance from rail. Trip arm of automatic train stop device when in the stop position shall be...

  12. 49 CFR 236.531 - Trip arm; height and distance from rail.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Trip arm; height and distance from rail. 236.531... Train Stop, Train Control and Cab Signal Systems Rules and Instructions; Roadway § 236.531 Trip arm; height and distance from rail. Trip arm of automatic train stop device when in the stop position shall be...

  13. 49 CFR 236.531 - Trip arm; height and distance from rail.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Trip arm; height and distance from rail. 236.531... Train Stop, Train Control and Cab Signal Systems Rules and Instructions; Roadway § 236.531 Trip arm; height and distance from rail. Trip arm of automatic train stop device when in the stop position shall be...

  14. 49 CFR 236.531 - Trip arm; height and distance from rail.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Trip arm; height and distance from rail. 236.531... Train Stop, Train Control and Cab Signal Systems Rules and Instructions; Roadway § 236.531 Trip arm; height and distance from rail. Trip arm of automatic train stop device when in the stop position shall be...

  15. 49 CFR 236.531 - Trip arm; height and distance from rail.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Trip arm; height and distance from rail. 236.531... Train Stop, Train Control and Cab Signal Systems Rules and Instructions; Roadway § 236.531 Trip arm; height and distance from rail. Trip arm of automatic train stop device when in the stop position shall be...

  16. Control and applications of cooperating disparate robotic manipulators relevant to nuclear waste management

    NASA Technical Reports Server (NTRS)

    Lew, Jae Young; Book, Wayne J.

    1991-01-01

    Remote handling in nuclear waste management requires a robotic system with precise motion as well as a large workspace. The concept of a small arm mounted on the end of a large arm may satisfy such needs. However, the performance of such a serial configuration lacks payload capacity which is a crucial factor for handling a massive object. Also, this configuration induces more flexibility on the structure. To overcome these problems, the topology of bracing the tip of the small arm (not the large arm) and having an end effector in the middle of the chain is proposed in this paper. Also, control of these cooperating disparate manipulators is accomplished in computer simulations. Thus, this robotic system can have the accuracy of the small arm, and at the same time, it can have the payload capacity and large workspace of the large arm.

  17. Design and pilot evaluation of competitive and cooperative exercise games for arm rehabilitation at home.

    PubMed

    Gorsic, Maja; Novak, Domen

    2016-08-01

    People with chronic arm impairment should exercise intensely at home after completing their clinical rehabilitation program, but frequently lack motivation. To address this issue, we present a home rehabilitation system that motivates patients by allowing them to perform arm exercises together with friends or relatives in competitive and cooperative games. Inertial sensors are used to track the patient's arm and control the game. The system was tested with seven adults with arm impairment as well as their friends or spouses. They tested four exercise games (single-player, competitive and two different cooperative games) for 3 minutes each. Of the 7 participants, 4 preferred the competitive game, 2 preferred a cooperative game, and 1 preferred to exercise alone. Competition also increased exercise intensity (measured using inertial sensors) compared to exercising alone. Though preliminary, these results indicate that competitive exercise games could improve arm rehabilitation at home for survivors of neurological and orthopedic injuries.

  18. Reprogramming the articulated robotic arm for glass handling by using Arduino microcontroller

    NASA Astrophysics Data System (ADS)

    Razali, Zol Bahri; Kader, Mohamed Mydin M. Abdul; Kadir, Mohd Asmadi Akmal; Daud, Mohd Hisam

    2017-09-01

    The application of articulated robotic arm in industries is raised due to the expansion of using robot to replace human task, especially for the harmful tasks. However a few problems happen with the program use to schedule the arm, Thus the purpose of this project is to design, fabricate and integrate an articulated robotic arm by using Arduino microcontroller for handling glass sorting system. This project was designed to segregate glass and non-glass waste which would be pioneer step for recycling. This robotic arm has four servo motors to operate as a whole; three for the body and one for holding mechanism. This intelligent system is controlled by Arduino microcontroller and build with optical sensor to provide the distinguish objects that will be handled. Solidworks model was used to produce the detail design of the robotic arm and make the mechanical properties analysis by using a CAD software.

  19. Object recognition for autonomous robot utilizing distributed knowledge database

    NASA Astrophysics Data System (ADS)

    Takatori, Jiro; Suzuki, Kenji; Hartono, Pitoyo; Hashimoto, Shuji

    2003-10-01

    In this paper we present a novel method of object recognition utilizing a remote knowledge database for an autonomous robot. The developed robot has three robot arms with different sensors; two CCD cameras and haptic sensors. It can see, touch and move the target object from different directions. Referring to remote knowledge database of geometry and material, the robot observes and handles the objects to understand them including their physical characteristics.

  20. ARM Radiosondes for National Polar-Orbiting Operational Environmental Satellite System Preparatory Project Validation Field Campaign Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borg, Lori; Tobin, David; Reale, Anthony

    This IOP has been a coordinated effort involving the U.S. Department of Energy (DOE) Atmospheric Radiation (ARM) Climate Research Facility, the University of Wisconsin (UW)-Madison, and the JPSS project to validate SNPP NOAA Unique Combined Atmospheric Processing System (NUCAPS) temperature and moisture sounding products from the Cross-track Infrared Sounder (CrIS) and the Advanced Technology Microwave Sounder (ATMS). In this arrangement, funding for radiosondes was provided by the JPSS project to ARM. These radiosondes were launched coincident with the SNPP satellite overpasses (OP) at four of the ARM field sites beginning in July 2012 and running through September 2017. Combined withmore » other ARM data, an assessment of the radiosonde data quality was performed and post-processing corrections applied producing an ARM site Best Estimate (BE) product. The SNPP targeted radiosondes were integrated into the NOAA Products Validation System (NPROVS+) system, which collocated the radiosondes with satellite products (NOAA, National Aeronautics and Space Administration [NASA], European Organisation for the Exploitation of Meteorological Satellites [EUMETSAT], Geostationary Operational Environmental Satellite [GOES], Constellation Observing System for Meteorology, Ionosphere, and Climate [COSMIC]) and Numerical Weather Prediction (NWP forecasts for use in product assessment and algorithm development. This work was a fundamental, integral, and cost-effective part of the SNPP validation effort and provided critical accuracy assessments of the SNPP temperature and water vapor soundings.« less

  1. Analyzing octopus movements using three-dimensional reconstruction.

    PubMed

    Yekutieli, Yoram; Mitelman, Rea; Hochner, Binyamin; Flash, Tamar

    2007-09-01

    Octopus arms, as well as other muscular hydrostats, are characterized by a very large number of degrees of freedom and a rich motion repertoire. Over the years, several attempts have been made to elucidate the interplay between the biomechanics of these organs and their control systems. Recent developments in electrophysiological recordings from both the arms and brains of behaving octopuses mark significant progress in this direction. The next stage is relating these recordings to the octopus arm movements, which requires an accurate and reliable method of movement description and analysis. Here we describe a semiautomatic computerized system for 3D reconstruction of an octopus arm during motion. It consists of two digital video cameras and a PC computer running custom-made software. The system overcomes the difficulty of extracting the motion of smooth, nonrigid objects in poor viewing conditions. Some of the trouble is explained by the problem of light refraction in recording underwater motion. Here we use both experiments and simulations to analyze the refraction problem and show that accurate reconstruction is possible. We have used this system successfully to reconstruct different types of octopus arm movements, such as reaching and bend initiation movements. Our system is noninvasive and does not require attaching any artificial markers to the octopus arm. It may therefore be of more general use in reconstructing other nonrigid, elongated objects in motion.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Myers, R.K.

    This paper examines the political and technical verification issues associated with proposals to place quantitative and/or qualitative limits on the deployment of nuclear-armed sea-launched cruise missiles (SLCMs). Overviews of the arms control relationship between the United States and the Soviet Union, the development of the SLCM, and Soviet and American concepts of verification are presented. The views of the American arms control and defense communities regarding the SLCM is discussed in depth, accompanied by a detailed examination of the various methods which have been proposed to verify a SLCM limitation agreement. The conclusion is that there are no technological barriers,more » per se, to SLCM verification, but as the decision on an agreement's verifiability is a political one, the U.S. Navy should concentrate its arguments against SLCM limitations on the weapon's operational utility rather than argue that such an agreement is unverifiable.« less

  3. SRMS History, Evolution and Lessons Learned

    NASA Technical Reports Server (NTRS)

    Jorgensen, Glenn; Bains, Elizabeth

    2011-01-01

    Early in the development of the Space Shuttle, it became clear that NASA needed a method of deploying and retrieving payloads from the payload bay. The Shuttle Remote Manipulator System (SRMS) was developed to fill this need. The 50 foot long robotic arm is an anthropomorphic design consisting of three electromechanical joints, six degrees of freedom, and two boom segments. Its composite boom construction provided a light weight solution needed for space operations. Additionally, a method of capturing payloads with the arm was required and a unique End Effector was developed using an electromechanical snare mechanism. The SRMS is operated using a Displays and Controls Panel and hand controllers located within the aft crew compartment of the shuttle. Although the SRMS was originally conceived to deploy and retrieve payloads, its generic capabilities allowed it to perform many other functions not originally conceived of. Over the years it has been used for deploying and retrieving constrained and free flying payloads, maneuvering and supporting EVA astronauts, satellite repair, International Space Station construction, and as a viewing aid for on-orbit International Space Station operations. After the Columbia accident, a robotically compatible Orbiter Boom Sensor System (OBSS) was developed and used in conjunction with the SRMS to scan the Thermal Protection System (TPS) of the shuttle. These scans ensure there is not a breach of the TPS prior to shuttle re-entry. Ground operations and pre mission simulation, analysis and planning played a major role in the success of the SRMS program. A Systems Engineering Simulator (SES) was developed to provide a utility complimentary to open loop engineering simulations. This system provided a closed-loop real-time pilot-driven simulation giving visual feedback, display and control panel interaction, and integration with other vehicle systems, such as GN&C. It has been useful for many more applications than traditional training. Evolution of the simulations, guided by the Math Model Working Group, showed the utility of input from multiple modeling groups with a structured forum for discussion.There were many unique development challenges in the areas of hardware, software, certification, modeling and simulation. Over the years, upgrades and enhancements were implemented to increase the capability, performance and safety of the SRMS. The history and evolution of the SRMS program provided many lessons learned that can be used for future space robotic systems.

  4. Journey to the center of the galaxy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chaisson, E.

    1980-08-01

    The solar system is a member of the Orion Arm of the Milky Way, far from the center of the Galaxy. This article takes the reader on a hypothetical journey from the solar system to the center of the Galaxy. Results from radio and infrared studies are used to suggest what such a journey might reveal. Traveling from the solar system toward the center, one crosses the Cygnus Arm, then the Sagittarius Arm, and then the so-called Three-kiloparsec Arm. The Arms contain a mixture of young stars as well as lots of gas and dust. Radio studies show that themore » Three-kiloparsec Arm is more like a ring than an arm. Inside this ring, is another ring composed of giant molecular clouds. Radio and infrared astronomers have discovered that the heart of the Galaxy is composed of matter in most perplexing states. There are three regions known within this innermost thousand light-years. First, there is a large zone of thin, hot ionized gas. Within this, there is a whirlpool of dense, warm matter. And further embedded, there seems to be a small supermassive object at the center. Possibly this object could be a blackhole. Researchers are continuing to examine, monitor, and model this mysterious region, the galactic nuclei. (SC)« less

  5. Gas Sensors Based on Single-Arm Waveguide Interferometers

    NASA Technical Reports Server (NTRS)

    Sarkisov, Sergey; Curley, Michael; Diggs, Darnell; Adamovsky, Grigory

    1998-01-01

    Various optical technologies can be implemented in chemical sensing. Sensitive, rugged, and compact systems will be more likely built using interferometric waveguide sensors. Currently existing sensors comprise dual-arm systems with external reference arm, dual-arm devices with internal reference arm such as integrated Mach-Zehnder interferometer, and single-arm systems which employ the interference between different waveguide modes. These latter ones are the most compact and rugged but still sensitive enough to monitor volatile pollutants such as NH3 coming out of industrial refrigerators and fertilizer plants and stocks, NO, NO2, SO2, emitted by industrial burning processes. Single-arm devices in planar waveguide configuration most frequently use two orthogonally polarized modes TE (sub i) and TM (sub i) of the same order i. Sensing effect is based on the difference in propagation conditions for the modes caused by the environment. However, dual-mode single-order interferometers still have relatively low sensitivity with respect to the environment related changes in the waveguide core because of small difference between propagation constants of TE (sub i) and TM (sub i) modes of the same order. Substantial sensitivity improvement without significant complication can be achieved for planar waveguide interferometers using modes of different orders with much greater difference between propagation constants.

  6. Quantifying Associations between Environmental and Social Stressors

    EPA Science Inventory

    Introduction: Association rule mining (ARM) has been widely used to identify associations between various entities in many fields. Although some studies have utilized it to analyze the relationship between chemicals and human effects, fewer have used this technique to identify an...

  7. [Surgical Correction of Scoliosis: Does Intraoperative CT Navigation Prolong Operative Time?

    PubMed

    Skála-Rosenbaum, J; Ježek, M; Džupa, V; Kadeřábek, R; Douša, P; Rusnák, R; Krbec, M

    2016-01-01

    PURPOSE OF THE STUDY The aim of the study was to compare the duration of corrective surgery for scoliosis in relation to the intra-operative use of either fluoroscopic or CT navigation. MATERIAL AND METHODS The indication for surgery was adolescent idiopathic scoliosis in younger patients and degenerative scoliosis in middleage or elderly patients. In a retrospective study, treatment outcomes in 43 consecutive patients operated on between April 2011 and April 2014 were compared. Only patients undergoing surgical correction of five or more spinal segments (fixation of six and more vertebrae) were included. RESULTS Transpedicular screw fixation of six to 13 vertebrae was performed under C-arm fluoroscopy guidance in 22 patients, and transpedicular screws were inserted in six to 14 vertebrae using the O-arm imaging system in 21 patients. A total of 246 screws were placed using the C-arm system and 340 screws were inserted using the O-arm system (p < 0.001). The procedures with use of the O-arm system were more complicated and required an average operative time longer by 48% (measured from the first skin incision to the completion of skin suture). However, the mean time needed for one screw placement (the sum of all surgical procedures with the use of a navigation technique divided by the number of screws placed using this technique) was the same in both techniques (19 min). DISCUSSION With good teamwork (surgeons, anaesthesiologists and a radiologist attending to the O-arm system), the time required to obtain one intra-operative CT scan is 3 to 5 minutes. The study showed that the mean time for placement of one screw was identical in both techniques although the average operative time was longer in surgery with O-arm navigation. The 19- minute interval was not the real placement time per screw. It was the sum of all operative times of surgical procedures (from first incision to suture completion including the whole approach within the range of planned stabilization) which used the same navigation technique divided by the number of all screws inserted during the procedures. The longer average operative time in procedures using O-arm navigation was not related to taking intra-operative O-arm scans. The authors consider surgery with an O-arm imaging system to be a safer procedure and use it currently in surgical correction of scoliosis. CONCLUSIONS The study focused on the length of surgery to correct scoliosis performed using either conventional fluoroscopy (C-arm) or intra-operative CT scanning (O-arm) showed that the mean placement time for one screw was identical in both imaging techniques when six or more vertebrae were stabilised. The use of intra-operative CT navigation did not make the surgery longer, and the higher number of inserted screws provides evidence that this technique is safer and allows us to achieve good stability of the correction procedure. Key words: virtual CT guidance, O-arm, scoliosis, transpedicular screw.

  8. AMF3 ARM's Research Facility and MAOS at Oliktok Point Alaska

    NASA Astrophysics Data System (ADS)

    Helsel, F.; Ivey, M.; Dexheimer, D.; Hardesty, J.; Lucero, D. A.; Roesler, E. L.

    2016-12-01

    Scientific Infrastructure To Support Atmospheric Science And Aerosol Science For The Department Of Energy's Atmospheric Radiation Measurement Programs Mobile Facility 3 Located At Oliktok Point, Alaska.The Atmospheric Radiation Measurement (ARM) Program's Mobile Facility 3 (AMF3) located at Oliktok Point, Alaska is a U.S. Department of Energy (DOE) site designed to collect data to determine the impact that clouds and aerosols have on solar radiation. The site provides a scientific infrastructure and data archives for the international Arctic research community. The infrastructure at Oliktok is designed to be mobile and it may be relocated in the future to support other ARM science missions. AMF3's present instruments include: scanning precipitation Radar-cloud radar, Raman Lidar, Eddy correlation flux systems, Ceilometer, Balloon sounding system, Atmospheric Emitted Radiance Interferometer (AERI), Micro-pulse Lidar (MPL), Millimeter cloud radar along with all the standard metrological measurements. A Mobile Aerosol Observing System (MAOS) has been added to AMF3 in 2016 more details of the instrumentation at www.arm.gov/sites/amf/mobile-aos. Data from these instruments are placed in the ARM data archives and are available to the international research community. This poster will discuss what instruments are at the ARM Program's AMF3 and highlight the newest addition to AMF3, the Mobile Aerosol Observing System (MAOS).

  9. ARM Tethered Balloon System & AALCO Activities at AMF3 Site at Oliktok Point, AK

    NASA Astrophysics Data System (ADS)

    Hardesty, J.; Dexheimer, D.; Mei, F.; Roesler, E. L.; Longbottom, C.; Hillman, B. R.

    2017-12-01

    Sandia National Laboratories (SNL) has operated the Atmospheric Radiation Measurement program's (ARM) third ARM Mobile Facility (AMF3) and the restricted airspace associated with it at Oliktok Point, Alaska, since October 2013. The site hosts ground-based instrumentation which collects a variety of continuous atmospheric measurements as well as user-conducted unmanned aircraft and tethered balloon campaigns. SNL has operated ARM's tethered balloon system (TBS) as part of the Inaugural Campaigns for ARM Research using Unmanned Systems (ICARUS) since 2016. AALCO (Aerial Assessment of Liquid in Clouds at Oliktok), is an ARM Intensive Operations Period conducted by SNL at the AMF3 since 2016. The operation of the TBS during ICARUS and AALCO to altitudes above 4,000' AGL in a variety of seasons and conditions is addressed. A Distributed Temperature Sensing (DTS) system and supercooled liquid water content (SLWC) sensors have been deployed under both campaigns. The performance of these sensors is discussed and results are presented. DTS measurements and their relationship to concurrent temperature measurements from unmanned aircraft and radiosondes are shown. SLWC sensor in situ measurements are compared with microwave radiometer and radiosonde-derived measurements. Preliminary analysis of using Large Eddy Simulations to compare with the SLWC measurements reveals three-dimensional properties of the observed clouds.

  10. Acute effects of vibration from a chipping hammer and a grinder on the hand-arm system.

    PubMed Central

    Kihlberg, S; Attebrant, M; Gemne, G; Kjellberg, A

    1995-01-01

    OBJECTIVES--The purpose of this study was to compare various effects on the hand-arm system of vibration exposure from a chipping hammer and a grinder with the same frequency weighted acceleration. Grip and push forces were measured and monitored during the exposure. The various effects were: muscle activity (measured with surface electrodes), discomfort ratings for different parts of the hand-arm system (made during and after exposure), and vibration perception threshold (for 10 minutes before and 10 minutes after the exposure). RESULTS--No increase in muscle activity due to exposure to vibration was found in the hand muscle studied. In the forearm, conversely, there was an increase in both muscle studied. For the upper arm the muscle activity only increased when exposed to impact vibration. Subjective ratings in the hand and shift in vibration perception threshold were effected more by the grinder than the hammer exposure. CONCLUSION--These results show that the reaction of the hand-arm system to vibration varies with frequency quantitatively as well as qualitatively. They do not support the notion that one single frequency weighted curve would be valid for the different health effects of hand-arm vibration (vascular, musculoskeletal, neurological, and psychophysiological). PMID:8535492

  11. PEPSI, the High-Resolution Optical-IR Spectrograph for the LBT

    NASA Astrophysics Data System (ADS)

    Andersen, Michael; Strassmeier, Klaus; Hoffman, Axel; Woche, Manfred; Spano, Paolo

    PEPSI is a high resolution fibre feed optical-IR polarimetric echelle spectrograph for the Large Binocular Telescope (LBT). PEPSI utilizes the two 8.4m LBT apertures to simultaneously record four polarization states at a resolution of 120.000. The extension of the coverage towards the IR is mainly motivated by the larger Zeeman splitting of IR lines, which would allow to study weaker/fainter magnetic structures on stars. The two optical arms, which also have an integral light mode with R up to 300.000, are under construction, while the IR arm is being designed.

  12. Neurosurgical robotic arm drilling navigation system.

    PubMed

    Lin, Chung-Chih; Lin, Hsin-Cheng; Lee, Wen-Yo; Lee, Shih-Tseng; Wu, Chieh-Tsai

    2017-09-01

    The aim of this work was to develop a neurosurgical robotic arm drilling navigation system that provides assistance throughout the complete bone drilling process. The system comprised neurosurgical robotic arm navigation combining robotic and surgical navigation, 3D medical imaging based surgical planning that could identify lesion location and plan the surgical path on 3D images, and automatic bone drilling control that would stop drilling when the bone was to be drilled-through. Three kinds of experiment were designed. The average positioning error deduced from 3D images of the robotic arm was 0.502 ± 0.069 mm. The correlation between automatically and manually planned paths was 0.975. The average distance error between automatically planned paths and risky zones was 0.279 ± 0.401 mm. The drilling auto-stopping algorithm had 0.00% unstopped cases (26.32% in control group 1) and 70.53% non-drilled-through cases (8.42% and 4.21% in control groups 1 and 2). The system may be useful for neurosurgical robotic arm drilling navigation. Copyright © 2016 John Wiley & Sons, Ltd.

  13. Continuous Evaluation of Fast Processes in Climate Models Using ARM Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Zhijin; Sha, Feng; Liu, Yangang

    2016-02-02

    This five-year award supports the project “Continuous Evaluation of Fast Processes in Climate Models Using ARM Measurements (FASTER)”. The goal of this project is to produce accurate, consistent and comprehensive data sets for initializing both single column models (SCMs) and cloud resolving models (CRMs) using data assimilation. A multi-scale three-dimensional variational data assimilation scheme (MS-3DVAR) has been implemented. This MS-3DVAR system is built on top of WRF/GSI. The Community Gridpoint Statistical Interpolation (GSI) system is an operational data assimilation system at the National Centers for Environmental Prediction (NCEP) and has been implemented in the Weather Research and Forecast (WRF) model.more » This MS-3DVAR is further enhanced by the incorporation of a land surface 3DVAR scheme and a comprehensive aerosol 3DVAR scheme. The data assimilation implementation focuses in the ARM SGP region. ARM measurements are assimilated along with other available satellite and radar data. Reanalyses are then generated for a few selected period of time. This comprehensive data assimilation system has also been employed for other ARM-related applications.« less

  14. A spatial registration method for navigation system combining O-arm with spinal surgery robot

    NASA Astrophysics Data System (ADS)

    Bai, H.; Song, G. L.; Zhao, Y. W.; Liu, X. Z.; Jiang, Y. X.

    2018-05-01

    The minimally invasive surgery in spinal surgery has become increasingly popular in recent years as it reduces the chances of complications during post-operation. However, the procedure of spinal surgery is complicated and the surgical vision of minimally invasive surgery is limited. In order to increase the quality of percutaneous pedicle screw placement, the O-arm that is a mobile intraoperative imaging system is used to assist surgery. The robot navigation system combined with O-arm is also increasing, with the extensive use of O-arm. One of the major problems in the surgical navigation system is to associate the patient space with the intra-operation image space. This study proposes a spatial registration method of spinal surgical robot navigation system, which uses the O-arm to scan a calibration phantom with metal calibration spheres. First, the metal artifacts were reduced in the CT slices and then the circles in the images based on the moments invariant could be identified. Further, the position of the calibration sphere in the image space was obtained. Moreover, the registration matrix is obtained based on the ICP algorithm. Finally, the position error is calculated to verify the feasibility and accuracy of the registration method.

  15. A numerical investigation of flow around octopus-like arms: near-wake vortex patterns and force development.

    PubMed

    Kazakidi, A; Vavourakis, V; Tsakiris, D P; Ekaterinaris, J A

    2015-01-01

    The fluid dynamics of cephalopods has so far received little attention in the literature, due to their complexity in structure and locomotion. The flow around octopuses, in particular, can be complicated due to their agile and dexterous arms, which frequently display some of the most diverse mechanisms of motion. The study of this flow amounts to a specific instance of the hydrodynamics problem for rough tapered cylinder geometries. The outstanding manipulative and locomotor skills of octopuses could inspire the development of advanced robotic arms, able to operate in fluid environments. Our primary aim was to study the hydrodynamic characteristics of such bio-inspired robotic models and to derive the hydrodynamic force coefficients as a concise description of the vortical flow effects. Utilizing computational fluid dynamic methods, the coefficients were computed on realistic morphologies of octopus-like arm models undergoing prescribed solid-body movements; such motions occur in nature for short durations in time, e.g. during reaching movements and exploratory behaviors. Numerical simulations were performed on translating, impulsively rotating, and maneuvering arms, around which the flow field structures were investigated. The results reveal in detail the generation of complex vortical flow structures around the moving arms. Hydrodynamic forces acting on a translating arm depend on the angle of incidence; forces generated during impulsive rotations of the arms are independent of their exact morphology and the angle of rotation; periodic motions based on a slow recovery and a fast power stroke are able to produce considerable propulsive thrust while harmonic motions are not. Parts of these results have been employed in bio-inspired models of underwater robotic mechanisms. This investigation may further assist elucidating the hydrodynamics underlying aspects of octopus locomotion and exploratory behaviors.

  16. Spatial Map of Synthesized Criteria for the Redundancy Resolution of Human Arm Movements.

    PubMed

    Li, Zhi; Milutinovic, Dejan; Rosen, Jacob

    2015-11-01

    The kinematic redundancy of the human arm enables the elbow position to rotate about the axis going through the shoulder and wrist, which results in infinite possible arm postures when the arm reaches to a target in a 3-D workspace. To infer the control strategy the human motor system uses to resolve redundancy in reaching movements, this paper compares five redundancy resolution criteria and evaluates their arm posture prediction performance using data on healthy human motion. Two synthesized criteria are developed to provide better real-time arm posture prediction than the five individual criteria. Of these two, the criterion synthesized using an exponential method predicts the arm posture more accurately than that using a least squares approach, and therefore is preferable for inferring the contributions of the individual criteria to motor control during reaching movements. As a methodology contribution, this paper proposes a framework to compare and evaluate redundancy resolution criteria for arm motion control. A cluster analysis which associates criterion contributions with regions of the workspace provides a guideline for designing a real-time motion control system applicable to upper-limb exoskeletons for stroke rehabilitation.

  17. virtX - evaluation of a computer-based training system for mobile C-arm systems in trauma and orthopedic surgery.

    PubMed

    Bott, O J; Teistler, M; Duwenkamp, C; Wagner, M; Marschollek, M; Plischke, M; Raab, B W; Stürmer, K M; Pretschner, D P; Dresing, K

    2008-01-01

    Operating room personnel (ORP) operating mobile image intensifier systems (C-arms) need training to produce high quality radiographs with a minimum of time and X-ray exposure. Our study aims at evaluating acceptance, usability and learning effect of the CBT system virtX that simulates C-arm based X-ray imaging in the context of surgical case scenarios. Prospective, interventional study conducted during an ORP course with three groups: intervention group 1 (training on a PC using virtX), and 2 (virtX with a C-arm as input device), and a control group (training without virtX) - IV1, IV2 and CG. All participants finished training with the same exercise. Time needed to produce an image of sufficient quality was recorded and analyzed using One-Way-ANOVA and Dunnett post hoc test (alpha = .05). Acceptance and usability of virtX have been evaluated using a questionnaire. CG members (n = 21) needed more time for the exercise than those of IV2 (n = 20): 133 +/- 55 vs. 101 +/- 37 sec. (p = .03). IV1 (n = 12) also performed better than CG (128 +/- 48 sec.), but this was not statistically significant. Seventy-nine participants returned a questionnaire (81% female, age 34 +/- 9 years, professional experience 8.3 +/- 7.6 years; 77% regularly used a C-arm). 83% considered virtX a useful addition to conventional C-arm training. 91% assessed virtual radiography as helpful for understanding C-arm operation. Trainees experienced virtX as substantial enhancement of C-arm training. Training with virtX can reduce the time needed to perform an imaging task.

  18. 2D–3D radiograph to cone-beam computed tomography (CBCT) registration for C-arm image-guided robotic surgery

    PubMed Central

    Liu, Wen Pei; Otake, Yoshito; Azizian, Mahdi; Wagner, Oliver J.; Sorger, Jonathan M.; Armand, Mehran; Taylor, Russell H.

    2015-01-01

    Purpose C-arm radiographs are commonly used for intraoperative image guidance in surgical interventions. Fluoroscopy is a cost-effective real-time modality, although image quality can vary greatly depending on the target anatomy. Cone-beam computed tomography (CBCT) scans are sometimes available, so 2D–3D registration is needed for intra-procedural guidance. C-arm radiographs were registered to CBCT scans and used for 3D localization of peritumor fiducials during a minimally invasive thoracic intervention with a da Vinci Si robot. Methods Intensity-based 2D–3D registration of intraoperative radiographs to CBCT was performed. The feasible range of X-ray projections achievable by a C-arm positioned around a da Vinci Si surgical robot, configured for robotic wedge resection, was determined using phantom models. Experiments were conducted on synthetic phantoms and animals imaged with an OEC 9600 and a Siemens Artis zeego, representing the spectrum of different C-arm systems currently available for clinical use. Results The image guidance workflow was feasible using either an optically tracked OEC 9600 or a Siemens Artis zeego C-arm, resulting in an angular difference of Δθ : ~ 30°. The two C-arm systems provided TREmean ≤ 2.5 mm and TREmean ≤ 2.0 mm, respectively (i.e., comparable to standard clinical intraoperative navigation systems). Conclusions C-arm 3D localization from dual 2D–3D registered radiographs was feasible and applicable for intraoperative image guidance during da Vinci robotic thoracic interventions using the proposed workflow. Tissue deformation and in vivo experiments are required before clinical evaluation of this system. PMID:25503592

  19. Developing UGVs for the FCS program

    NASA Astrophysics Data System (ADS)

    Kamsickas, Gary M.; Ward, John N.

    2003-09-01

    The FCS Operational Requirements Document (ORD) identifies unmanned systems as a key component of the FCS Unit of Action. FCS unmanned systems include Unmanned Aerial Vehicles (UAV), Unmanned Ground Vehicles (UGV), Unattended Ground Sensors (UGS) and Unattended Munitions (UM). Unmanned systems are intended to enhance the Unit of Action across the full range of operations when integrated with manned platforms. Unmanned systems will provide the commander with tools to gather battlespace information while significantly reducing overall soldier risk. Unmanned systems will be used in some cases to augment or replace human intervention to perform many of the dirty, dull and dangerous missions presently performed by soldiers and to serve as a combat multiplier for mission performance, force protection and survivability. This paper focuses on the application of UGVs within the FCS Unit of Action. There are three different UGVs planned to support the FCS Unit of Action; the Soldier Unmanned Ground Vehicle (SUGV); The Multi-role Utility Logistics Equipment (MULE) platform; and the Armed Robotic Vehicle (ARV).

  20. [Anterior odontoid screw fixation using intra-operative cone-beam computed tomography and navigation].

    PubMed

    Castro-Castro, Julián

    2014-01-01

    The purpose of this study was to asses the value of intraoperative cone-beam CT (O-arm) and stereotactic navigation for the insertion of anterior odontoid screws. this was a retrospective review of patients receiving surgical treatment for traumatic odontoid fractures during a period of 18 months. Procedures were guided with O-arm assistance in all cases. The screw position was verified with an intraoperative CT scan. Intraoperative and clinical parameters were evaluated. Odontoid fracture fusion was assessed on postoperative CT scans obtained at 3 and 6 months' follow-up Five patients were included in this series; 4 patients (80%) were male. Mean age was 63.6 years (range 35-83 years). All fractures were acute type ii odontoid fractures. The mean operative time was 116minutes (range 60-160minutes). Successful screw placement, judged by intraoperative computed tomography, was attained in all 5 patients (100%). The average preoperative and postoperative times were 8.6 (range 2-22 days) and 4.2 days (range 3-7 days) respectively. No neurological deterioration occurred after surgery. The rate of bone fusion was 80% (4/5). Although this initial study evaluated a small number of patients, anterior odontoid screw fixation utilizing the O-arm appears to be safe and accurate. This system allows immediate CT imaging in the operating room to verify screw position. Copyright © 2014 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  1. Assessment and model guided cancer screening promotion by village doctors in China: a randomized controlled trial protocol.

    PubMed

    Feng, Rui; Shen, Xingrong; Chai, Jing; Chen, Penglai; Cheng, Jing; Liang, Han; Zhao, Ting; Sha, Rui; Li, Kaichun; Wang, Debin

    2015-10-12

    Proven cost-effectiveness contrasted by low uptake of cancer screening (CS) calls for new methodologies promoting the service. Contemporary interventions in this regard relies primarily on strategies targeting general or specific groups with limited attention being paid to individualized approaches. This trial tests a novel package promoting CS utilization via continuous and tailored counseling delivered by primary caregivers. It aims at demonstrating that high risk individuals in the intervention arm will, compared to those in the delayed intervention condition, show increased use of CS service. The trial adopts a quasi-randomized controlled trial design and involves 2160 high risk individuals selected, via rapid and detailed risk assessments, from about 72,000 farmers aged 35+ in 36 administrative villages randomized into equal intervention and delayed intervention arms. The CS intervention package uses: a) village doctors and village clinics to deliver personalized and thus relatively sophisticated CS counseling; b) two-stage risk assessment models in identifying high risk individuals to focus the intervention on the most needed; c) standardized operation procedures to guide conduct of counseling; d) real-time effectiveness and quality monitoring to leverage continuous improvement; e) web-based electronic system to enable prioritizing complex determinants of CS uptake and tailoring counseling sessions to the changing needs of individual farmers. The intervention arm receives baseline and semiannual follow up evaluations plus CS counseling for 5 years; while the delayed intervention arm, only the same baseline and follow-up evaluations for the first 5 years and CS counseling starting from the 6th year if the intervention proved effective. Evaluation measures include: CS uptake by high risk farmers and changes in their knowledge, perceptions and self-efficacy about CS. Given the complexity and heterogeneity in the determinant system of individual CS service seeking behavior, personalized interventions may prove to be an effective strategy. The current trial distinguishes itself from previous ones in that it not only adopts a personalized strategy but also introduces a package of pragmatic solutions based on proven theories for tackling potential barriers and incorporating key success factors in a synergetic way toward low cost, effective and sustainable CS promotion. ISRCTN33269053.

  2. Establishment of one-axis vibration test system for measurement of biodynamic response of human hand-arm system.

    PubMed

    Shibata, Nobuyuki; Hosoya, Naoki; Maeda, Setsuo

    2008-12-01

    Prolonged exposure to hand-arm vibration (HAV) due to use of hand-held power tools leads to an increased occurrence of symptoms of disorders in the vascular, neurological, and osteo-articular systems of the upper limbs called hand-arm vibration syndrome (HAVS). Biodynamic responses of the hand-arm system to vibration can be suggestive parameters that give us better assessment of exposure to HAV and fundamental data for design of low-vibration-exposure power tools. Recently, a single axis hand-arm vibration system has been installed in the Japan National Institute of Occupational Safety and Health (NIOSH). The aims of this study were to obtain the fundamental dynamic characteristics of an instrumented handle and to validate the performance and measurement accuracy of the system applied to dynamic response measurement. A pseudo-random vibration signal with a frequency range of 5-1,250 Hz and a power spectrum density of 1.0 (m/s2)2/Hz was used in this study. First the dynamic response of the instrumented handle without any weight was measured. After this measurement, the dynamic response measurement of the handle with weights mounted on the handle was performed. The apparent mass of a weight itself was obtained by using the mass cancellation method. The mass of the measuring cap on the instrumented handle was well compensated by using the mass cancellation method. Based on the 10% error tolerance, this handle can reliably measure the dynamic response represented by an apparent mass with a minimum weight of 2.0 g in a frequency range of 10.0 to 1,000 Hz. A marked increase in the AM magnitude of the weights of 15 g and 20 g in frequency ranges greater than 800 Hz is attributed not to the fundamental resonance frequency of the handle with weights, but to the fixation of the weight to the measuring cap. In this aspect, the peak of the AM magnitude can be reduced and hence should not be an obstacle to the biodynamic response measurement of the human hand-arm system. On the basis of the results obtained in this study, we conclude that this hand-arm vibration test system can be used to measure biodynamic response parameters of the human hand-arm system.

  3. Radial arm strike rail

    DOEpatents

    McKeown, Mark H.; Beason, Steven C.

    1991-01-01

    The radial arm strike rail assembly is a system for measurement of bearings, directions, and stereophotography for geologic mapping, particularly where magnetic compasses are not appropriate. The radial arm, pivoting around a shaft axis, provides a reference direction determination for geologic mapping and bearing or direction determination. The centerable and levelable pedestal provide a base for the radial arm strike rail and the telescoping camera pedestal. The telescoping feature of the radial arm strike rail allows positioning the end of the rail for strike direction or bearing measurement with a goniometer.

  4. Jerk-level synchronous repetitive motion scheme with gradient-type and zeroing-type dynamics algorithms applied to dual-arm redundant robot system control

    NASA Astrophysics Data System (ADS)

    Chen, Dechao; Zhang, Yunong

    2017-10-01

    Dual-arm redundant robot systems are usually required to handle primary tasks, repetitively and synchronously in practical applications. In this paper, a jerk-level synchronous repetitive motion scheme is proposed to remedy the joint-angle drift phenomenon and achieve the synchronous control of a dual-arm redundant robot system. The proposed scheme is novelly resolved at jerk level, which makes the joint variables, i.e. joint angles, joint velocities and joint accelerations, smooth and bounded. In addition, two types of dynamics algorithms, i.e. gradient-type (G-type) and zeroing-type (Z-type) dynamics algorithms, for the design of repetitive motion variable vectors, are presented in detail with the corresponding circuit schematics. Subsequently, the proposed scheme is reformulated as two dynamical quadratic programs (DQPs) and further integrated into a unified DQP (UDQP) for the synchronous control of a dual-arm robot system. The optimal solution of the UDQP is found by the piecewise-linear projection equation neural network. Moreover, simulations and comparisons based on a six-degrees-of-freedom planar dual-arm redundant robot system substantiate the operation effectiveness and tracking accuracy of the robot system with the proposed scheme for repetitive motion and synchronous control.

  5. "Atmospheric Radiation Measurement (ARM) Research Facility at Oliktok Point Alaska"

    NASA Astrophysics Data System (ADS)

    Helsel, F.; Ivey, M.; Hardesty, J.; Roesler, E. L.; Dexheimer, D.

    2017-12-01

    Scientific Infrastructure To Support Atmospheric Science, Aerosol Science and UAS's for The Department Of Energy's Atmospheric Radiation Measurement Programs At The Mobile Facility 3 Located At Oliktok Point, Alaska.The Atmospheric Radiation Measurement (ARM) Program's Mobile Facility 3 (AMF3) located at Oliktok Point, Alaska is a U.S. Department of Energy (DOE) site designed to collect data and help determine the impact that clouds and aerosols have on solar radiation. AMF3 provides a scientific infrastructure to support instruments and collect arctic data for the international arctic research community. The infrastructure at AMF3/Oliktok is designed to be mobile and it may be relocated in the future to support other ARM science missions. AMF3's present base line instruments include: scanning precipitation Radars, cloud Radar, Raman Lidar, Eddy correlation flux systems, Ceilometer, Balloon sounding system, Atmospheric Emitted Radiance Interferometer (AERI), Micro-pulse Lidar (MPL) Along with all the standard metrological measurements. In addition AMF3 provides aerosol measurements with a Mobile Aerosol Observing System (MAOS). Ground support for Unmanned Aerial Systems (UAS) and tethered balloon flights. Data from these instruments and systems are placed in the ARM data archives and are available to the international research community. This poster will discuss what instruments and systems are at the ARM Research Facility at Oliktok Point Alaska.

  6. High-precision robotic microcontact printing (R-μCP) utilizing a vision guided selectively compliant articulated robotic arm.

    PubMed

    McNulty, Jason D; Klann, Tyler; Sha, Jin; Salick, Max; Knight, Gavin T; Turng, Lih-Sheng; Ashton, Randolph S

    2014-06-07

    Increased realization of the spatial heterogeneity found within in vivo tissue microenvironments has prompted the desire to engineer similar complexities into in vitro culture substrates. Microcontact printing (μCP) is a versatile technique for engineering such complexities onto cell culture substrates because it permits microscale control of the relative positioning of molecules and cells over large surface areas. However, challenges associated with precisely aligning and superimposing multiple μCP steps severely limits the extent of substrate modification that can be achieved using this method. Thus, we investigated the feasibility of using a vision guided selectively compliant articulated robotic arm (SCARA) for μCP applications. SCARAs are routinely used to perform high precision, repetitive tasks in manufacturing, and even low-end models are capable of achieving microscale precision. Here, we present customization of a SCARA to execute robotic-μCP (R-μCP) onto gold-coated microscope coverslips. The system not only possesses the ability to align multiple polydimethylsiloxane (PDMS) stamps but also has the capability to do so even after the substrates have been removed, reacted to graft polymer brushes, and replaced back into the system. Plus, non-biased computerized analysis shows that the system performs such sequential patterning with <10 μm precision and accuracy, which is equivalent to the repeatability specifications of the employed SCARA model. R-μCP should facilitate the engineering of complex in vivo-like complexities onto culture substrates and their integration with microfluidic devices.

  7. Effects of biomotor structures on performance of competitive gymnastics elements in elementary school female sixth-graders.

    PubMed

    Delas, Suncica; Babin, Josip; Katić, Ratko

    2007-12-01

    In order to identify biomotor systems that determine performance of competitive gymnastics elements in elementary school female sixth-graders, factor structures of morphological characteristics and basic motor abilities were determined first, followed by relations of the morphological-motor system factors obtained with a set of criterion variables evaluating specific motor skills in competitive gymnastics in 126 female children aged 12 years +/- 3 months. Factor analysis of 17 morphological measures yielded three morphological factors: factor of mesoendomorphy and/or adipose body voluminosity; factor of longitudinal body dimensionality; and factor of transverse arm dimensionality. Factor analysis of 16 motor variables produced four motor factors: general motoricity factor (motor system); general speed factor; factor of explosive strength of throwing type (arm explosiveness); and factor of arm and leg flexibility. Three significant canonical correlations, i.e. linear combinations, explained the association between the set of seven latent variables of the morphological and basic motor system, and five variables evaluating the knowledge in competitive gymnastics. The first canonical linear combination was based on a favorable and predominant impact of the general motor factor (a system integrating whole body coordination, leg explosiveness, relative arm strength, arm movement frequency and body flexibility) on performance of gymnastics elements, cartwheel, handstand and backward pullover mount in particular, and to a lesser extent front scale and double leg pirouette for 180 degrees. The relation of the second pair of canonical factors additionally explained the role of transverse dimensionality of arm skeleton, arm flexibility and explosiveness in performing cartwheel and squat vault, whereas the relation of the third pair of canonical factors explained the unfavorable impact of adipose voluminosity on the performance of squat vault and backward pullover mount.

  8. Representation of continuous hand and arm movements in macaque areas M1, F5, and AIP: a comparative decoding study

    NASA Astrophysics Data System (ADS)

    Menz, Veera Katharina; Schaffelhofer, Stefan; Scherberger, Hansjörg

    2015-10-01

    Objective. In the last decade, multiple brain areas have been investigated with respect to their decoding capability of continuous arm or hand movements. So far, these studies have mainly focused on motor or premotor areas like M1 and F5. However, there is accumulating evidence that anterior intraparietal area (AIP) in the parietal cortex also contains information about continuous movement. Approach. In this study, we decoded 27 degrees of freedom representing complete hand and arm kinematics during a delayed grasping task from simultaneously recorded activity in areas M1, F5, and AIP of two macaque monkeys (Macaca mulatta). Main results. We found that all three areas provided decoding performances that lay significantly above chance. In particular, M1 yielded highest decoding accuracy followed by F5 and AIP. Furthermore, we provide support for the notion that AIP does not only code categorical visual features of objects to be grasped, but also contains a substantial amount of temporal kinematic information. Significance. This fact could be utilized in future developments of neural interfaces restoring hand and arm movements.

  9. 49 CFR 236.702 - Arm, semaphore.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Arm, semaphore. 236.702 Section 236.702 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.702 Arm...

  10. 49 CFR 236.702 - Arm, semaphore.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Arm, semaphore. 236.702 Section 236.702 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.702 Arm...

  11. 49 CFR 236.702 - Arm, semaphore.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Arm, semaphore. 236.702 Section 236.702 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.702 Arm...

  12. 49 CFR 236.702 - Arm, semaphore.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Arm, semaphore. 236.702 Section 236.702 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.702 Arm...

  13. Air Force Reading Abilities Test: Utilization Assessment.

    DTIC Science & Technology

    1984-03-01

    the R&DI AFHRL. TR-78.82, Predichon of Reading Grade Li.s of Seim. AApdwo from Armed Serice. Vocaionaj Ap ude Batery (ASVAB); AFHRL.TR-80-11, Reading...4. Vocabulary words that showed a likelihood of being encountered in an Air Force work environment were to be selected. Esoteric adverbs and...is not only used in the Basic Military Training environment ; it is also utilized at every Base Education Office through the OJT program. As noted

  14. Effect of genetic testing for risk of type 2 diabetes mellitus on health behaviors and outcomes: study rationale, development and design.

    PubMed

    Cho, Alex H; Killeya-Jones, Ley A; O'Daniel, Julianne M; Kawamoto, Kensaku; Gallagher, Patrick; Haga, Susanne; Lucas, Joseph E; Trujillo, Gloria M; Joy, Scott V; Ginsburg, Geoffrey S

    2012-01-18

    Type 2 diabetes is a prevalent chronic condition globally that results in extensive morbidity, decreased quality of life, and increased health services utilization. Lifestyle changes can prevent the development of diabetes, but require patient engagement. Genetic risk testing might represent a new tool to increase patients' motivation for lifestyle changes. Here we describe the rationale, development, and design of a randomized controlled trial (RCT) assessing the clinical and personal utility of incorporating type 2 diabetes genetic risk testing into comprehensive diabetes risk assessments performed in a primary care setting. Patients are recruited in the laboratory waiting areas of two primary care clinics and enrolled into one of three study arms. Those interested in genetic risk testing are randomized to receive either a standard risk assessment (SRA) for type 2 diabetes incorporating conventional risk factors plus upfront disclosure of the results of genetic risk testing ("SRA+G" arm), or the SRA alone ("SRA" arm). Participants not interested in genetic risk testing will not receive the test, but will receive SRA (forming a third, "no-test" arm). Risk counseling is provided by clinic staff (not study staff external to the clinic). Fasting plasma glucose, insulin levels, body mass index (BMI), and waist circumference are measured at baseline and 12 months, as are patients' self-reported behavioral and emotional responses to diabetes risk information. Primary outcomes are changes in insulin resistance and BMI after 12 months; secondary outcomes include changes in diet patterns, physical activity, waist circumference, and perceived risk of developing diabetes. The utility, feasibility, and efficacy of providing patients with genetic risk information for common chronic diseases in primary care remain unknown. The study described here will help to establish whether providing type 2 diabetes genetic risk information in a primary care setting can help improve patients' clinical outcomes, risk perceptions, and/or their engagement in healthy behavior change. In addition, study design features such as the use of existing clinic personnel for risk counseling could inform the future development and implementation of care models for the use of individual genetic risk information in primary care. ClinicalTrials.gov: NCT00849563.

  15. Estimating outcomes and cost effectiveness using a single-arm clinical trial: ofatumumab for double-refractory chronic lymphocytic leukemia.

    PubMed

    Hatswell, Anthony J; Thompson, Gwilym J; Maroudas, Penny A; Sofrygin, Oleg; Delea, Thomas E

    2017-01-01

    Ofatumumab (Arzerra ® , Novartis) is a treatment for chronic lymphocytic leukemia refractory to fludarabine and alemtuzumab [double refractory (DR-CLL)]. Ofatumumab was licensed on the basis of an uncontrolled Phase II study, Hx-CD20-406, in which patients receiving ofatumumab survived for a median of 13.9 months. However, the lack of an internal control arm presents an obstacle for the estimation of comparative effectiveness. The objective of the study was to present a method to estimate the cost effectiveness of ofatumumab in the treatment of DR-CLL. As no suitable historical control was available for modelling, the outcomes from non-responders to ofatumumab were used to model the effect of best supportive care (BSC). This was done via a Cox regression to control for differences in baseline characteristics between groups. This analysis was included in a partitioned survival model built in Microsoft ® Excel with utilities and costs taken from published sources, with costs and quality-adjusted life years (QALYs) were discounted at a rate of 3.5% per annum. Using the outcomes seen in non-responders, ofatumumab is expected to add approximately 0.62 life years (1.50 vs. 0.88). Using published utility values this translates to an additional 0.30 QALYs (0.77 vs. 0.47). At the list price, ofatumumab had a cost per QALY of £130,563, and a cost per life year of £63,542. The model was sensitive to changes in assumptions regarding overall survival estimates and utility values. This study demonstrates the potential of using data for non-responders to model outcomes for BSC in cost-effectiveness evaluations based on single-arm trials. Further research is needed on the estimation of comparative effectiveness using uncontrolled clinical studies.

  16. Open-Label Randomized Trial of Titrated Disease Management for Patients with Hypertension: Study Design and Baseline Sample Characteristics

    PubMed Central

    Jackson, George L.; Weinberger, Morris; Kirshner, Miriam A.; Stechuchak, Karen M.; Melnyk, Stephanie D.; Bosworth, Hayden B.; Coffman, Cynthia J.; Neelon, Brian; Van Houtven, Courtney; Gentry, Pamela W.; Morris, Isis J.; Rose, Cynthia M.; Taylor, Jennifer P.; May, Carrie L.; Han, Byungjoo; Wainwright, Christi; Alkon, Aviel; Powell, Lesa; Edelman, David

    2016-01-01

    Despite the availability of efficacious treatments, only half of patients with hypertension achieve adequate blood pressure (BP) control. This paper describes the protocol and baseline subject characteristics of a 2-arm, 18-month randomized clinical trial of titrated disease management (TDM) for patients with pharmaceutically-treated hypertension for whom systolic blood pressure (SBP) is not controlled (≥140mmHg for non-diabetic or ≥130mmHg for diabetic patients). The trial is being conducted among patients of four clinic locations associated with a Veterans Affairs Medical Center. An intervention arm has a TDM strategy in which patients' hypertension control at baseline, 6, and 12 months determines the resource intensity of disease management. Intensity levels include: a low-intensity strategy utilizing a licensed practical nurse to provide bi-monthly, non-tailored behavioral support calls to patients whose SBP comes under control; medium-intensity strategy utilizing a registered nurse to provide monthly tailored behavioral support telephone calls plus home BP monitoring; and high-intensity strategy utilizing a pharmacist to provide monthly tailored behavioral support telephone calls, home BP monitoring, and pharmacist-directed medication management. Control arm patients receive the low-intensity strategy regardless of BP control. The primary outcome is SBP. There are 385 randomized (192 intervention; 193 control) veterans that are predominately older (mean age 63.5 years) men (92.5%). 61.8% are African American, and the mean baseline SBP for all subjects is 143.6mmHg. This trial will determine if a disease management program that is titrated by matching the intensity of resources to patients' BP control leads to superior outcomes compared to a low-intensity management strategy. PMID:27417982

  17. A population of wheat multiple synthetic derivatives: an effective platform to explore, harness and utilize genetic diversity of Aegilops tauschii for wheat improvement.

    PubMed

    Gorafi, Yasir Serag Alnor; Kim, June-Sik; Elbashir, Awad Ahmed Elawad; Tsujimoto, Hisashi

    2018-04-28

    The multiple synthetic derivatives platform described in this study will provide an opportunity for effective utilization of Aegilops tauschii traits and genes for wheat breeding. Introducing genes from wild relatives is the best option to increase genetic diversity and discover new alleles necessary for wheat improvement. A population harboring genomic fragments from the diploid wheat progenitor Aegilops tauschii Coss. in the background of bread wheat (Triticum aestivum L.) was developed by crossing and backcrossing 43 synthetic wheat lines with the common wheat cultivar Norin 61. We named this population multiple synthetic derivatives (MSD). To validate the suitability of this population for wheat breeding and genetic studies, we randomly selected 400 MSD lines and genotyped them by using Diversity Array Technology sequencing markers. We scored black glume as a qualitative trait and heading time in two environments in Sudan as a quantitative trait. Our results showed high genetic diversity and less recombination which is expected from the nature of the population. Genome-wide association (GWA) analysis showed one QTL at the short arm of chromosome 1D different from those alleles reported previously indicating that black glume in the MSD population is controlled by new allele at the same locus. For heading time, from the two environments, GWA analysis revealed three QTLs on the short arms of chromosomes 2A, 2B and 2D and two on the long arms of chromosomes 5A and 5D. Using the MSD population, which represents the diversity of 43 Ae. tauschii accessions representing most of its natural habitat, QTLs or genes and desired phenotypes (such as drought, heat and salinity tolerance) could be identified and selected for utilization in wheat breeding.

  18. Open-label randomized trial of titrated disease management for patients with hypertension: Study design and baseline sample characteristics.

    PubMed

    Jackson, George L; Weinberger, Morris; Kirshner, Miriam A; Stechuchak, Karen M; Melnyk, Stephanie D; Bosworth, Hayden B; Coffman, Cynthia J; Neelon, Brian; Van Houtven, Courtney; Gentry, Pamela W; Morris, Isis J; Rose, Cynthia M; Taylor, Jennifer P; May, Carrie L; Han, Byungjoo; Wainwright, Christi; Alkon, Aviel; Powell, Lesa; Edelman, David

    2016-09-01

    Despite the availability of efficacious treatments, only half of patients with hypertension achieve adequate blood pressure (BP) control. This paper describes the protocol and baseline subject characteristics of a 2-arm, 18-month randomized clinical trial of titrated disease management (TDM) for patients with pharmaceutically-treated hypertension for whom systolic blood pressure (SBP) is not controlled (≥140mmHg for non-diabetic or ≥130mmHg for diabetic patients). The trial is being conducted among patients of four clinic locations associated with a Veterans Affairs Medical Center. An intervention arm has a TDM strategy in which patients' hypertension control at baseline, 6, and 12months determines the resource intensity of disease management. Intensity levels include: a low-intensity strategy utilizing a licensed practical nurse to provide bi-monthly, non-tailored behavioral support calls to patients whose SBP comes under control; medium-intensity strategy utilizing a registered nurse to provide monthly tailored behavioral support telephone calls plus home BP monitoring; and high-intensity strategy utilizing a pharmacist to provide monthly tailored behavioral support telephone calls, home BP monitoring, and pharmacist-directed medication management. Control arm patients receive the low-intensity strategy regardless of BP control. The primary outcome is SBP. There are 385 randomized (192 intervention; 193 control) veterans that are predominately older (mean age 63.5years) men (92.5%). 61.8% are African American, and the mean baseline SBP for all subjects is 143.6mmHg. This trial will determine if a disease management program that is titrated by matching the intensity of resources to patients' BP control leads to superior outcomes compared to a low-intensity management strategy. Published by Elsevier Inc.

  19. Data management and scientific integration within the Atmospheric Radiation Measurement Program

    NASA Technical Reports Server (NTRS)

    Gracio, Deborah K.; Hatfield, Larry D.; Yates, Kenneth R.; Voyles, Jimmy W.; Tichler, Joyce L.; Cederwall, Richard T.; Laufersweiler, Mark J.; Leach, Martin J.; Singley, Paul

    1995-01-01

    The Atmospheric Radiation Measurement (ARM) Program has been developed by the U.S. Department of Energy with the goal to improve the predictive capabilities of General Circulation Models (GCM's) in their treatment of clouds and radiative transfer effects. To achieve this goal, three experimental testbeds were designed for the deployment of instruments that will collect atmospheric data used to drive the GCM's. Each site, known as a Cloud and Radiation Testbed (CART), consists of a highly available, redundant data system for the collection of data from a variety of instrumentation. The first CART site was deployed in April 1992 in the Southern Great Plains (SGP), Lamont, Oklahoma, with the other two sites to follow in September 1995 in the Tropical Western Pacific and in 1997 on the North Slope of Alaska. Approximately 400 MB of data are transferred per day via the Internet from the SGP site to the ARM Experiment Center at Pacific Northwest Laboratory in Richland, Washington. The Experiment Center is central to the ARM data path and provides for the collection, processing, analysis, and delivery of ARM data. Data are received from the CART sites from a variety of instrumentation, observational systems, amd external data sources. The Experiment Center processes these data streams on a continuous basis to provide derived data products to the ARM Science Team in near real-time while providing a three-month running archive of data. A primary requirement of the ARM Program is to preserve and protect all data produced or acquired. This function is performed at Oak Ridge National Laboratory where leading edge technology is employed for the long-term storage of ARM data. The ARM Archive provides access to data for participation outside of the ARM Program. The ARM Program involves a collaborative effort by teams from various DOE National Laboratories, providing multi-disciplinary areas of expertise. This paper will discuss the collaborative methods in which the ARM teams translate the scientific goals of the Program into data products. By combining atmospheric scientists, systems engineers, and software engineers, the ARM Program has successfully designed and developed an environment where advances in understanding the parameterizations of GCM's can be made.

  20. OBSS and RMS arm during a survey of the TPS during STS-115

    NASA Image and Video Library

    2006-09-09

    S115-E-05307 (10 Sept. 2006) --- As in the case of the previous two shuttle missions, a tandem of the orbiter boom sensor system (OBSS) and the remote manipulator system (RMS) arm conducts a survey of the thermal protection system on the Space Shuttle Atlantis.

  1. The Computerized Adaptive Testing System Development Project.

    ERIC Educational Resources Information Center

    McBride, James R.; Sympson, J. B.

    The Computerized Adaptive Testing (CAT) project is a joint Armed Services coordinated effort to develop and evaluate a system for automated, adaptive administration of the Armed Services Vocational Aptitude Battery (ASVAB). The CAT is a system for administering personnel tests that differs from conventional test administration in two major…

  2. An arm wearable haptic interface for impact sensing on unmanned aerial vehicles

    NASA Astrophysics Data System (ADS)

    Choi, Yunshil; Hong, Seung-Chan; Lee, Jung-Ryul

    2017-04-01

    In this paper, an impact monitoring system using fiber Bragg grating (FBG) sensors and vibro-haptic actuators has been introduced. The system is suggested for structural health monitoring (SHM) for unmanned aerial vehicles (UAVs), by making a decision with human-robot interaction. The system is composed with two major subsystems; an on-board system equipped on UAV and an arm-wearable interface for ground pilot. The on-board system acquires impact-induced wavelength changes and performs localization process, which was developed based on arrival time calculation. The arm-wearable interface helps ground pilots to make decision about impact location themselves by stimulating their tactile-sense with motor vibration.

  3. Aerial Radiological Measuring System (ARMS): systems, procedures and sensitivity (1976)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boyns, P K

    1976-07-01

    This report describes the Aerial Radiological Measuring System (ARMS) designed and operated by EG and G, Inc., for the Energy Research and Development Administration's (ERDA) Division of Operational Safety with the cooperation of the Nuclear Regulatory Commission. Designed to rapidly survey large areas for low-level man-made radiation, the ARMS has also proven extremely useful in locating lost radioactive sources of relatively low activity. The system consists of sodium iodide scintillation detectors, data formatting and recording equipment, positioning equipment, meteorological instruments, direct readout hardware, and data analysis equipment. The instrumentation, operational procedures, data reduction techniques and system sensitivities are described, togethermore » with their applications and sample results.« less

  4. Spoken language and arm gestures are controlled by the same motor control system.

    PubMed

    Gentilucci, Maurizio; Dalla Volta, Riccardo

    2008-06-01

    Arm movements can influence language comprehension much as semantics can influence arm movement planning. Arm movement itself can be used as a linguistic signal. We reviewed neurophysiological and behavioural evidence that manual gestures and vocal language share the same control system. Studies of primate premotor cortex and, in particular, of the so-called "mirror system", including humans, suggest the existence of a dual hand/mouth motor command system involved in ingestion activities. This may be the platform on which a combined manual and vocal communication system was constructed. In humans, speech is typically accompanied by manual gesture, speech production itself is influenced by executing or observing transitive hand actions, and manual actions play an important role in the development of speech, from the babbling stage onwards. Behavioural data also show reciprocal influence between word and symbolic gestures. Neuroimaging and repetitive transcranial magnetic stimulation (rTMS) data suggest that the system governing both speech and gesture is located in Broca's area. In general, the presented data support the hypothesis that the hand motor-control system is involved in higher order cognition.

  5. Octopus-inspired multi-arm robotic swimming.

    PubMed

    Sfakiotakis, M; Kazakidi, A; Tsakiris, D P

    2015-05-13

    The outstanding locomotor and manipulation characteristics of the octopus have recently inspired the development, by our group, of multi-functional robotic swimmers, featuring both manipulation and locomotion capabilities, which could be of significant engineering interest in underwater applications. During its little-studied arm-swimming behavior, as opposed to the better known jetting via the siphon, the animal appears to generate considerable propulsive thrust and rapid acceleration, predominantly employing movements of its arms. In this work, we capture the fundamental characteristics of the corresponding complex pattern of arm motion by a sculling profile, involving a fast power stroke and a slow recovery stroke. We investigate the propulsive capabilities of a multi-arm robotic system under various swimming gaits, namely patterns of arm coordination, which achieve the generation of forward, as well as backward, propulsion and turning. A lumped-element model of the robotic swimmer, which considers arm compliance and the interaction with the aquatic environment, was used to study the characteristics of these gaits, the effect of various kinematic parameters on propulsion, and the generation of complex trajectories. This investigation focuses on relatively high-stiffness arms. Experiments employing a compliant-body robotic prototype swimmer with eight compliant arms, all made of polyurethane, inside a water tank, successfully demonstrated this novel mode of underwater propulsion. Speeds of up to 0.26 body lengths per second (approximately 100 mm s(-1)), and propulsive forces of up to 3.5 N were achieved, with a non-dimensional cost of transport of 1.42 with all eight arms and of 0.9 with only two active arms. The experiments confirmed the computational results and verified the multi-arm maneuverability and simultaneous object grasping capability of such systems.

  6. Nearly automatic motion capture system for tracking octopus arm movements in 3D space.

    PubMed

    Zelman, Ido; Galun, Meirav; Akselrod-Ballin, Ayelet; Yekutieli, Yoram; Hochner, Binyamin; Flash, Tamar

    2009-08-30

    Tracking animal movements in 3D space is an essential part of many biomechanical studies. The most popular technique for human motion capture uses markers placed on the skin which are tracked by a dedicated system. However, this technique may be inadequate for tracking animal movements, especially when it is impossible to attach markers to the animal's body either because of its size or shape or because of the environment in which the animal performs its movements. Attaching markers to an animal's body may also alter its behavior. Here we present a nearly automatic markerless motion capture system that overcomes these problems and successfully tracks octopus arm movements in 3D space. The system is based on three successive tracking and processing stages. The first stage uses a recently presented segmentation algorithm to detect the movement in a pair of video sequences recorded by two calibrated cameras. In the second stage, the results of the first stage are processed to produce 2D skeletal representations of the moving arm. Finally, the 2D skeletons are used to reconstruct the octopus arm movement as a sequence of 3D curves varying in time. Motion tracking, segmentation and reconstruction are especially difficult problems in the case of octopus arm movements because of the deformable, non-rigid structure of the octopus arm and the underwater environment in which it moves. Our successful results suggest that the motion-tracking system presented here may be used for tracking other elongated objects.

  7. Braking System for Wind Turbines

    NASA Technical Reports Server (NTRS)

    Krysiak, J. E.; Webb, F. E.

    1987-01-01

    Operating turbine stopped smoothly by fail-safe mechanism. Windturbine braking systems improved by system consisting of two large steel-alloy disks mounted on high-speed shaft of gear box, and brakepad assembly mounted on bracket fastened to top of gear box. Lever arms (with brake pads) actuated by spring-powered, pneumatic cylinders connected to these arms. Springs give specific spring-loading constant and exert predetermined load onto brake pads through lever arms. Pneumatic cylinders actuated positively to compress springs and disengage brake pads from disks. During power failure, brakes automatically lock onto disks, producing highly reliable, fail-safe stops. System doubles as stopping brake and "parking" brake.

  8. Retrieving Liquid Water Path and Precipitable Water Vapor from the Atmospheric Radiation Measurement (ARM) Microwave Radiometers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Turner, David D.; Clough, Shepard A.; Liljegren, James C.

    2007-11-01

    Ground-based two-channel microwave radiometers have been used for over 15 years by the Atmospheric Radiation Measurement (ARM) program to provide observations of downwelling emitted radiance from which precipitable water vapor (PWV) and liquid water path (LWP) – twp geophysical parameters critical for many areas of atmospheric research – are retrieved. An algorithm that utilizes two advanced retrieval techniques, a computationally expensive physical-iterative approach and an efficient statistical method, has been developed to retrieve these parameters. An important component of this Microwave Retrieval (MWRRET) algorithm is the determination of small (< 1K) offsets that are subtracted from the observed brightness temperaturesmore » before the retrievals are performed. Accounting for these offsets removes systematic biases from the observations and/or the model spectroscopy necessary for the retrieval, significantly reducing the systematic biases in the retrieved LWP. The MWRRET algorithm provides significantly more accurate retrievals than the original ARM statistical retrieval which uses monthly retrieval coefficients. By combining the two retrieval methods with the application of brightness temperature offsets to reduce the spurious LWP bias in clear skies, the MWRRET algorithm provides significantly better retrievals of PWV and LWP from the ARM 2-channel microwave radiometers compared to the original ARM product.« less

  9. Multi-arm multilateral haptics-based immersive tele-robotic system (HITS) for improvised explosive device disposal

    NASA Astrophysics Data System (ADS)

    Erickson, David; Lacheray, Hervé; Lai, Gilbert; Haddadi, Amir

    2014-06-01

    This paper presents the latest advancements of the Haptics-based Immersive Tele-robotic System (HITS) project, a next generation Improvised Explosive Device (IED) disposal (IEDD) robotic interface containing an immersive telepresence environment for a remotely-controlled three-articulated-robotic-arm system. While the haptic feedback enhances the operator's perception of the remote environment, a third teleoperated dexterous arm, equipped with multiple vision sensors and cameras, provides stereo vision with proper visual cues, and a 3D photo-realistic model of the potential IED. This decentralized system combines various capabilities including stable and scaled motion, singularity avoidance, cross-coupled hybrid control, active collision detection and avoidance, compliance control and constrained motion to provide a safe and intuitive control environment for the operators. Experimental results and validation of the current system are presented through various essential IEDD tasks. This project demonstrates that a two-armed anthropomorphic Explosive Ordnance Disposal (EOD) robot interface can achieve complex neutralization techniques against realistic IEDs without the operator approaching at any time.

  10. KSC-02pd0554

    NASA Image and Video Library

    2002-04-23

    KENNEDY SPACE CENTER, FLA. -- The STS-111 crew looks at the replacement pitch roll joint for the SSRMS (Canadarm 2) they will be installing on the mission to the International Space Station. The crew comprises Commander Kenneth Cockrell, Pilot Paul Lockhart, and Mission Specialists Franklin Chang-Diaz and Phillippe Perrin, who is with the French Space Agency. Part of the payload on mission STS-111 is the Mobile Base System (MBS), which will be installed on the Mobile Transporter to complete the Canadian Mobile Servicing System, or MSS. The mechanical arm will then have the capability to "inchworm" from the U.S. Lab Destiny to the MSS and travel along the truss to work sites. STS-111 is the second utilization flight (UF-2) to the Space Station and will also carry the Expedition 5 crew to replace Expedition 4. Launch is scheduled for May 30, 2002

  11. KSC-02pd0555

    NASA Image and Video Library

    2002-04-23

    KENNEDY SPACE CENTER, FLA. -- The STS-111 crew looks at the replacement pitch roll joint for the SSRMS (Canadarm 2) they will be installing on the mission to the International Space Station. The crew comprises Commander Kenneth Cockrell, Pilot Paul Lockhart, and Mission Specialists Franklin Chang-Diaz and Phillippe Perrin, who is with the French Space Agency. Part of the payload on mission STS-111 is the Mobile Base System (MBS), which will be installed on the Mobile Transporter to complete the Canadian Mobile Servicing System, or MSS. The mechanical arm will then have the capability to "inchworm" from the U.S. Lab Destiny to the MSS and travel along the truss to work sites. STS-111 is the second utilization flight (UF-2) to the Space Station and will also carry the Expedition 5 crew to replace Expedition 4. Launch is scheduled for May 30, 2002

  12. KSC-02pd0783

    NASA Image and Video Library

    2002-05-28

    KENNEDY SPACE CENTER, FLA. - STS-111 Mission Specialist Philippe Perrin, with the French Space Agency, undergoes suit check as part of pre-launch activities. The mission, known as Utilization Flight 2, is carrying supplies and equipment to the Station. The payload includes the Multi-Purpose Logistics Module Leonardo, the Mobile Base System, which will be installed on the Mobile Transporter to complete the Canadian Mobile Servicing System, or MSS, and a replacement wrist/roll joint for Canadarm 2. The mechanical arm will then have the capability to "inchworm" from the U.S. Lab Destiny to the MSS and travel along the truss to work sites. Also part of the mission, Expedition 5 will travel to the International Space Station as the replacement crew for Expedition 4, who will return to Earth aboard the orbiter. Launch is scheduled for May 30, 2002

  13. Preemptive Ethanol Lock Therapy in Pediatric Hematology/Oncology Patients With Catheter-Associated Bloodstream Infection: Impact on Length of Stay, Cost, and Catheter Salvage.

    PubMed

    McGrath, Eric; Du, Wei; Rajpurkar, Madhvi

    2018-03-01

    Ethanol lock therapy (ELT) with systemic antimicrobial therapy is a promising therapy for catheter-related infection (CRI). The impact of ELT timing on treatment efficacy and costs is unknown. A prospective study was conducted in the Hematology/Oncology Unit at the Children's Hospital of Michigan. Patients with suspected CRI were randomized to Preemptive ELT arm or Rescue ELT arm after positive culture. Five cases in Preemptive arm and 9 in Rescue arm had a confirmed CRI. All cases cleared infection with line salvage with no adverse events due to ELT or recurrence within 14 days. Our data showed a trend toward 36% reduction in average hospital costs and 40% reduction in average length of stay in Preemptive arm over Rescue arm. Although a small study, our data on preemptive ELT with systemic antimicrobial therapy suggest a potentially important treatment strategy in reducing length of stay as well as hospital costs.

  14. Embodied prosthetic arm stabilizes body posture, while unembodied one perturbs it.

    PubMed

    Imaizumi, Shu; Asai, Tomohisa; Koyama, Shinichi

    2016-10-01

    Senses of ownership (this arm belongs to me) and agency (I am controlling this arm) originate from sensorimotor system. External objects can be integrated into the sensorimotor system following long-term use, and recognized as one's own body. We examined how an (un)embodied prosthetic arm modulates whole-body control, and assessed the components of prosthetic embodiment. Nine unilateral upper-limb amputees participated. Four frequently used their prosthetic arm, while the others rarely did. Their postural sway was measured during quiet standing with or without their prosthesis. The frequent users showed greater sway when they removed the prosthesis, while the rare users showed greater sway when they fitted the prosthesis. Frequent users reported greater everyday feelings of postural stabilization by prosthesis and a larger sense of agency over the prosthesis. We suggest that a prosthetic arm maintains or perturbs postural control, depending on the prosthetic embodiment, which involves sense of agency rather than ownership. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. A Decade of MWC 758 Disk Images: Where Are the Spiral-arm-driving Planets?

    NASA Astrophysics Data System (ADS)

    Ren, Bin; Dong, Ruobing; Esposito, Thomas M.; Pueyo, Laurent; Debes, John H.; Poteet, Charles A.; Choquet, Élodie; Benisty, Myriam; Chiang, Eugene; Grady, Carol A.; Hines, Dean C.; Schneider, Glenn; Soummer, Rémi

    2018-04-01

    Large-scale spiral arms have been revealed in scattered light images of a few protoplanetary disks. Theoretical models suggest that such arms may be driven by and corotate with giant planets, which has called for remarkable observational efforts to look for them. By examining the rotation of the spiral arms for the MWC 758 system over a 10 year timescale, we are able to provide dynamical constraints on the locations of their perturbers. We present reprocessed Hubble Space Telescope (HST)/NICMOS F110W observations of the target in 2005, and the new Keck/NIRC2 L‧-band observations in 2017. MWC 758's two well-known spiral arms are revealed in the NICMOS archive at the earliest observational epoch. With additional Very Large Telescope (VLT)/SPHERE data, our joint analysis leads to a pattern speed of 0\\buildrel{\\circ}\\over{.} {6}-0\\buildrel{\\circ\\over{.} 6}+3\\buildrel{\\circ\\over{.} 3} {yr}}-1 at 3σ for the two major spiral arms. If the two arms are induced by a perturber on a near-circular orbit, its best-fit orbit is at 89 au (0.″59), with a 3σ lower limit of 30 au (0.″20). This finding is consistent with the simulation prediction of the location of an arm-driving planet for the two major arms in the system.

  16. Measurement of Galactic Logarithmic Spiral Arm Pitch Angle Using Two-Dimensional Fast Fourier Transform Decomposition

    NASA Astrophysics Data System (ADS)

    Davis, Benjamin L.; Berrier, J. C.; Shields, D. W.; Kennefick, J.; Kennefick, D.; Seigar, M. S.; Lacy, C. H. S.; Puerari, I.

    2012-01-01

    A logarithmic spiral is a prominent feature appearing in a majority of observed galaxies. This feature has long been associated with the traditional Hubble classification scheme, but historical quotes of pitch angle of spiral galaxies have been almost exclusively qualitative. We have developed a methodology, utilizing Two-Dimensional Fast Fourier Transformations of images of spiral galaxies, in order to isolate and measure the pitch angles of their spiral arms. Our technique provides a quantitative way to measure this morphological feature. This will allow the precise comparison of spiral galaxy evolution to other galactic parameters and test spiral arm genesis theories. In this work, we detail our image processing and analysis of spiral galaxy images and discuss the robustness of our analysis techniques. The authors gratefully acknowledge support for this work from NASA Grant NNX08AW03A.

  17. The Development of the Speaker Independent ARM Continuous Speech Recognition System

    DTIC Science & Technology

    1992-01-01

    spokeTi airborne reconnaissance reports u-ing a speech recognition system based on phoneme-level hidden Markov models (HMMs). Previous versions of the ARM...will involve automatic selection from multiple model sets, corresponding to different speaker types, and that the most rudimen- tary partition of a...The vocabulary size for the ARM task is 497 words. These words are related to the phoneme-level symbols corresponding to the models in the model set

  18. Research on the relationship of the probe system for the swing arm profilometer based on the point source microscope

    NASA Astrophysics Data System (ADS)

    Gao, Mingxing; Jing, Hongwei; Cao, Xuedong; Chen, Lin; Yang, Jie

    2015-08-01

    When using the swing arm profilometer (SAP) to measure the aspheric mirror and the off-axis aspheric mirror, the error of the effective arm length of the SAP has an obvious influence on the measurement result. In order to reduce the influence of the effective arm length and increase the measurement accuracy of the SAP, the laser tracker is adopted to measure the effective arm length. Because the space position relationship of the probe system for the SAP is needed to measured before using the laser tracker, the point source microscope (PSM) is used to measure the space positional relationship. The measurement principle of the PSM and other applications are introduced; the accuracy and repeatability of this technology are analysed; the advantages and disadvantages of this technology are summarized.

  19. ENGINEERING MANPOWER BULLETIN NUMBER 9.

    ERIC Educational Resources Information Center

    ALDEN, JOHN D.

    DESIGNED TO INFORM LEADERS IN INDUSTRY, GOVERNMENT, AND EDUCATION, WHOSE RESPONSIBILITY INCLUDES AWARENESS OF ENGINEERING MANPOWER DEVELOPMENTS, THIS BULLETIN REPORTS A STUDY CONDUCTED BY THE ENGINEERING MANPOWER COMMISSION OF ENGINEERS IN THE ARMED SERVICES. THE WORK OF THE COMMISSION IS TO ASSURE THE MOST EFFECTIVE UTILIZATION OF ENGINEERING…

  20. Fatigue Transfer in Endurance Performance

    ERIC Educational Resources Information Center

    Caplan, Calvin S.

    1976-01-01

    This study investigated the question as to whether or not fatigue produced by performance of heavy physical work involving the legs would transfer to and impair following performance that utilized the muscles of the arms; under certain exercises and conditions transfer was found to take place. (JD)

  1. Nitric oxide nanoparticles: pre-clinical utility as a therapeutic for intramuscular abscesses.

    PubMed

    Schairer, David; Martinez, Luis R; Blecher, Karin; Chouake, Jason; Nacharaju, Parimala; Gialanella, Philip; Friedman, Joel M; Nosanchuk, Joshua D; Friedman, Adam

    2012-01-01

    Nitric oxide (NO) is a critical component of host defense against invading pathogens; however, its therapeutic utility is limited due to a lack of practical delivery systems. Recently, a NO-releasing nanoparticulate platform (NO-np) was shown to have in vitro broad-spectrum antimicrobial activity and in vivo pre-clinical efficacy in a dermal abscess model. To extend these findings, both topical (TP) and intralesional (IL) NO-np administration was evaluated in a MRSA intramuscular murine abscess model and compared with vancomycin. All treatment arms accelerated abscess clearance clinically, histologically, and by microbiological assays on both days 4 and 7 following infection. However, abscesses treated with NO-np via either route demonstrated a more substantial, statistically significant decrease in bacterial survival based on colony forming unit assays and histologically revealed less inflammatory cell infiltration and preserved muscular architecture. These data suggest that the NO-np may be an effective addition to our armament for deep soft tissue infections.

  2. Economic analysis of routine neuromonitoring of recurrent laryngeal nerve in total thyroidectomy.

    PubMed

    Sanabria, Álvaro; Ramírez, Adonis

    2015-01-01

    Thyroidectomy is a common surgery. Routine searching of the recurrent laryngeal nerve is the most important strategy to avoid palsy. Neuromonitoring has been recommended to decrease recurrent laryngeal nerve palsy. To assess if neuromonitoring of recurrent laryngeal nerve during thyroidectomy is cost-effective in a developing country. We designed a decision analysis to assess the cost-effectiveness of recurrent laryngeal nerve neuromonitoring. For probabilities, we used data from a meta-analysis. Utility was measured using preference values. We considered direct costs. We conducted a deterministic and a probabilistic analysis. We did not find differences in utility between arms. The frequency of recurrent laryngeal nerve injury was 1% in the neuromonitor group and 1.6% for the standard group. Thyroidectomy without monitoring was the less expensive alternative. The incremental cost-effectiveness ratio was COP$ 9,112,065. Routine neuromonitoring in total thyroidectomy with low risk of recurrent laryngeal nerve injury is neither cost-useful nor cost-effective in the Colombian health system.

  3. On the Value of Estimating Human Arm Stiffness during Virtual Teleoperation with Robotic Manipulators

    PubMed Central

    Buzzi, Jacopo; Ferrigno, Giancarlo; Jansma, Joost M.; De Momi, Elena

    2017-01-01

    Teleoperated robotic systems are widely spreading in multiple different fields, from hazardous environments exploration to surgery. In teleoperation, users directly manipulate a master device to achieve task execution at the slave robot side; this interaction is fundamental to guarantee both system stability and task execution performance. In this work, we propose a non-disruptive method to study the arm endpoint stiffness. We evaluate how users exploit the kinetic redundancy of the arm to achieve stability and precision during the execution of different tasks with different master devices. Four users were asked to perform two planar trajectories following virtual tasks using both a serial and a parallel link master device. Users' arm kinematics and muscular activation were acquired and combined with a user-specific musculoskeletal model to estimate the joint stiffness. Using the arm kinematic Jacobian, the arm end-point stiffness was derived. The proposed non-disruptive method is capable of estimating the arm endpoint stiffness during the execution of virtual teleoperated tasks. The obtained results are in accordance with the existing literature in human motor control and show, throughout the tested trajectory, a modulation of the arm endpoint stiffness that is affected by task characteristics and hand speed and acceleration. PMID:29018319

  4. Integrative rehabilitation of elderly stroke survivors: the design and evaluation of the BrightArm™.

    PubMed

    Rabin, Bryan A; Burdea, Grigore C; Roll, Doru T; Hundal, Jasdeep S; Damiani, Frank; Pollack, Simcha

    2012-07-01

    To describe the development of the BrightArm upper extremity rehabilitation system, and to determine its clinical feasibility with older hemiplegic patients. The BrightArm adjusted arm gravity loading through table tilting. Patients wore an arm support that sensed grasp strength and communicated wirelessly with a personal computer. Games were written to improve cognitive, psychosocial and the upper extremity motor function and adapted automatically to each patient. The system underwent feasibility trials spanning 6 weeks. Participants were evaluated pre-therapy, post-therapy, and at 6 weeks follow-up using standardized clinical measures. Computerized measures of supported arm reach and game performance were stored on a remote server. Five participants had clinically significant improvements in their active range of shoulder movement, shoulder strength, grasp strength, and their ability to focus. Several participants demonstrated substantially higher arm function (measured with the Fugl-Meyer test) and two were less-depressed (measured with the Becks Depression Inventory, Second Edition). The BrightArm technology was well-accepted by the participants, who gave it an overall subjective rating of 4.1 on a 5 point Likert scale. Given these preliminary findings, it will be beneficial to evaluate the BrightArm through controlled clinical trials and to investigate its application to other clinical populations.

  5. Integrative rehabilitation of elderly stroke survivors: The design and evaluation of the BrightArm™

    PubMed Central

    Rabin, Bryan A.; Burdea, Grigore C.; Roll, Doru T.; Hundal, Jasdeep S.; Damiani, Frank; Pollack, Simcha

    2011-01-01

    Purpose To describe the development of the BrightArm upper extremity rehabilitation system, and to determine its clinical feasibility with older hemiplegic patients. Method The BrightArm adjusted arm gravity loading through table tilting. Patients wore an arm support that sensed grasp strength and communicated wirelessly with a personal computer. Games were written to improve cognitive, psychosocial and the upper extremity motor function and adapted automatically to each patient. The system underwent feasibility trials spanning 6 weeks. Participants were evaluated pre-therapy, post-therapy, and at 6 weeks follow-up using standardized clinical measures. Computerized measures of supported arm reach and game performance were stored on a remote server. Results Five participants had clinically significant improvements in their active range of shoulder movement, shoulder strength, grasp strength, and their ability to focus. Several participants demonstrated substantially higher arm function (measured with the Fugl-Meyer test) and two were less-depressed (measured with the Becks Depression Inventory, Second Edition). The BrightArm technology was well-accepted by the participants, who gave it an overall subjective rating of 4.1 on a 5 point Likert scale. Conclusions Given these preliminary findings, it will be beneficial to evaluate the BrightArm through controlled clinical trials and to investigate its application to other clinical populations. PMID:22107353

  6. Circular tomosynthesis for neuro perfusion imaging on an interventional C-arm

    NASA Astrophysics Data System (ADS)

    Claus, Bernhard E.; Langan, David A.; Al Assad, Omar; Wang, Xin

    2015-03-01

    There is a clinical need to improve cerebral perfusion assessment during the treatment of ischemic stroke in the interventional suite. The clinician is able to determine whether the arterial blockage was successfully opened but is unable to sufficiently assess blood flow through the parenchyma. C-arm spin acquisitions can image the cerebral blood volume (CBV) but are challenged to capture the temporal dynamics of the iodinated contrast bolus, which is required to derive, e.g., cerebral blood flow (CBF) and mean transit time (MTT). Here we propose to utilize a circular tomosynthesis acquisition on the C-arm to achieve the necessary temporal sampling of the volume at the cost of incomplete data. We address the incomplete data problem by using tools from compressed sensing and incorporate temporal interpolation to improve our temporal resolution. A CT neuro perfusion data set is utilized for generating a dynamic (4D) volumetric model from which simulated tomo projections are generated. The 4D model is also used as a ground truth reference for performance evaluation. The performance that may be achieved with the tomo acquisition and 4D reconstruction (under simulation conditions, i.e., without considering data fidelity limitations due to imaging physics and imaging chain) is evaluated. In the considered scenario, good agreement between the ground truth and the tomo reconstruction in the parenchyma was achieved.

  7. Strength tests for elite rowers: low- or high-repetition?

    PubMed

    Lawton, Trent W; Cronin, John B; McGuigan, Michael R

    2014-01-01

    The purpose of this project was to evaluate the utility of low- and high-repetition maximum (RM) strength tests used to assess rowers. Twenty elite heavyweight males (age 23.7 ± 4.0 years) performed four tests (5 RM, 30 RM, 60 RM and 120 RM) using leg press and seated arm pulling exercise on a dynamometer. Each test was repeated on two further occasions; 3 and 7 days from the initial trial. Per cent typical error (within-participant variation) and intraclass correlation coefficients (ICCs) were calculated using log-transformed repeated-measures data. High-repetition tests (30 RM, 60 RM and 120 RM), involving seated arm pulling exercise are not recommended to be included in an assessment battery, as they had unsatisfactory measurement precision (per cent typical error > 5% or ICC < 0.9). Conversely, low-repetition tests (5 RM) involving leg press and seated arm pulling exercises could be used to assess elite rowers (per cent typical error ≤ 5% and ICC ≥ 0.9); however, only 5 RM leg pressing met criteria (per cent typical error = 2.7%, ICC = 0.98) for research involving small samples (n = 20). In summary, low-repetition 5 RM strength testing offers greater utility as assessments of rowers, as they can be used to measure upper- and lower-body strength; however, only the leg press exercise is recommended for research involving small squads of elite rowers.

  8. Report: Basic Facts About Military Service.

    ERIC Educational Resources Information Center

    High School News Service (DOD), Great Lakes, IL.

    The purpose of the report is to inform students, through counselors and advisers, of opportunities and responsibilities in the Armed Forces. The topics covered are: missions of the Armed Forces, the selective service system, enlistment programs, reserve components, commissioning programs, auxiliary benefits, women in the Armed Forces, and basic…

  9. DIABEO App Software and Telemedicine Versus Usual Follow-Up in the Treatment of Diabetic Patients: Protocol for the TELESAGE Randomized Controlled Trial.

    PubMed

    Jeandidier, Nathalie; Chaillous, Lucy; Franc, Sylvia; Benhamou, Pierre-Yves; Schaepelynck, Pauline; Hanaire, Hélène; Catargi, Bogdan; Farret, Anne; Fontaine, Pierre; Guerci, Bruno; Reznik, Yves; Penfornis, Alfred; Borot, Sophie; Serusclat, Pierre; Kherbachi, Yacine; D'Orsay, Geneviève; Detournay, Bruno; Simon, Pierre; Charpentier, Guillaume

    2018-04-19

    Self-management of diabetes minimizes the risk of macrovascular and microvascular complications, but understanding and/or adherence to self-management recommendations is often suboptimal. DIABEO is a smartphone app (downloaded via the internet) used to calculate bolus insulin doses. A previous study (TELEDIAB 1) showed that the use of DIABEO was associated with a significant improvement in glycemic control in patients with poorly controlled type 1 diabetes mellitus, particularly when combined with teleconsultations with physicians. Here, we present the protocol for a new study (Suivi A Grande Echelle d'une cohorte de diabétiques de type 1 et de type 2 sous schéma insulinique basal bolus par la TELEmédecine; abbreviated TELESAGE), conducted in a larger population of diabetic patients with poorly controlled basal-bolus insulin levels. TELESAGE is a multicenter, double-randomized, open-label, three parallel-arms study, conducted in approximately 100 centers in France. The study will compare a control group (arm 1: usual follow-up) with two DIABEO telemedicine systems: (1) physician-assisted telemedicine (arm 2), and (2) nurse-assisted telemonitoring and teleconsultations by a diabetologist's task delegation (arm 3). Initial randomization will allocate the study arms in 12 French regions. A second randomization will assign patients in the groups allocated to each studied region. The primary objective of TELESAGE will be to investigate the effect of the DIABEO telemedicine system versus usual follow-up, with respect to improvements in the glycated hemoglobin levels of approximately 696 diabetic patients with poorly controlled basal-bolus insulin levels. The TELESAGE study is sponsored by Sanofi (Gentilly, France). A primary completion date is expected in June 2018, and publication of results is expected within 6 months of work completion. The TELESAGE study is expected to confirm the previous results of the TELEDIAB 1 study using a larger sample of diabetic patients. It is also expected to evaluate a nurse-assisted telemonitoring system. We will assess the potential of the DIABEO telemedicine service in terms of its utility and explore whether it can become an integral part of diabetes care for patients. ClinicalTrials.gov NCT02287532; https://clinicaltrials.gov/ct2/show/NCT02287532 (Archived by WebCite at http://www.webcitation.org/6ykajhJKd). ©Nathalie Jeandidier, Lucy Chaillous, Sylvia Franc, Pierre-Yves Benhamou, Pauline Schaepelynck, Hélène Hanaire, Bogdan Catargi, Anne Farret, Pierre Fontaine, Bruno Guerci, Yves Reznik, Alfred Penfornis, Sophie Borot, Pierre Serusclat, Yacine Kherbachi, Geneviève D'Orsay, Bruno Detournay, Pierre Simon, Guillaume Charpentier. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 19.04.2018.

  10. Development of a Stereo Vision Measurement System for a 3D Three-Axial Pneumatic Parallel Mechanism Robot Arm

    PubMed Central

    Chiang, Mao-Hsiung; Lin, Hao-Ting; Hou, Chien-Lun

    2011-01-01

    In this paper, a stereo vision 3D position measurement system for a three-axial pneumatic parallel mechanism robot arm is presented. The stereo vision 3D position measurement system aims to measure the 3D trajectories of the end-effector of the robot arm. To track the end-effector of the robot arm, the circle detection algorithm is used to detect the desired target and the SAD algorithm is used to track the moving target and to search the corresponding target location along the conjugate epipolar line in the stereo pair. After camera calibration, both intrinsic and extrinsic parameters of the stereo rig can be obtained, so images can be rectified according to the camera parameters. Thus, through the epipolar rectification, the stereo matching process is reduced to a horizontal search along the conjugate epipolar line. Finally, 3D trajectories of the end-effector are computed by stereo triangulation. The experimental results show that the stereo vision 3D position measurement system proposed in this paper can successfully track and measure the fifth-order polynomial trajectory and sinusoidal trajectory of the end-effector of the three- axial pneumatic parallel mechanism robot arm. PMID:22319408

  11. A compensation method of lever arm effect for tri-axis hybrid inertial navigation system based on fiber optic gyro

    NASA Astrophysics Data System (ADS)

    Liu, Zengjun; Wang, Lei; Li, Kui; Gao, Jiaxin

    2017-05-01

    Hybrid inertial navigation system (HINS) is a new kind of inertial navigation system (INS), which combines advantages of platform INS, strap-down INS and rotational INS. HINS has a physical platform to isolate the angular motion as platform INS does, HINS also uses strap-down attitude algorithms and applies rotation modulation technique. Tri-axis HINS has three gimbals to isolate the angular motion in the dynamic base, in which way the system can reduce the effects of angular motion and improve the positioning precision. However, the angular motion will affect the compensation of some error parameters, especially for the lever arm effect. The lever arm effect caused by position errors between the accelerometers and rotation center cannot be ignored due to the rapid rotation of inertial measurement unit (IMU) and it will cause fluctuation and stage in velocity in HINS. The influences of angular motion on the lever arm effect compensation are analyzed firstly in this paper, and then the compensation method of lever arm effect based on the photoelectric encoders in dynamic base is proposed. Results of experiments on turntable show that after compensation, the fluctuations and stages in velocity curve disappear.

  12. Enabling technologies for robot assisted ultrasound tomography.

    PubMed

    Aalamifar, Fereshteh; Khurana, Rishabh; Cheng, Alexis; Guo, Xiaoyu; Iordachita, Iulian; Boctor, Emad M

    2017-03-01

    Currently available ultrasound (US) tomography systems suggest utilizing cylindrical transducers that can be used for a specific organ. In this paper, our focus is on an alternative way of creating US tomographic images that could be used for other anatomies and more general applications. This system consists of two conventional US probes facing each other while one or several of the transducers in one probe can act as the transmitter and the rest as the receiver. Aligning the two US probes is a challenging task. To address this issue, we propose a robot assisted US tomography system in which one probe is operated freehanded and another by a robotic arm. In this paper, enabling technologies for this system are described. With the current prototype, a reconstruction precision of 4.12, 1.73, and 2.23 mm for the three calibrations, and an overall alignment repeatability in the range of 5-9 mm were achieved. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  13. Health economics and cost-effectiveness research with special reference to hemato-oncology.

    PubMed

    Kumar, Rajat

    2013-07-01

    The cost of health care is increasing globally, especially in cancer. Health economics is an increasingly important field and medical professionals should have a working knowledge of the basis for health technology assessment such as cost-effectiveness analysis, cost utility analysis and cost benefit analysis. There are limited studies on health technology assessment regarding expensive therapies, primarily from high-income countries, but these cannot be applied to countries with different gross domestic product (GDP) and cost of health care delivery. There is a need to carry out health economics related research utilizing data from India. Whereas clinical trials establish the efficacy of new drugs in controlled environments, with strict inclusion and exclusion criteria, their transferability to the "real-world" situation is not always true. With the shifting of the global cancer burden to middle-income and lower middle-income countries, this field is going to assume greater importance in the future. Health economics research conducted in India may be of benefit to other countries with similar economies. The Armed Forces Medical Services of India, with a well-established system of assessing health outcomes, and robust system of accounting for expenses, can provide the lead for these studies.

  14. GPU implementation of prior image constrained compressed sensing (PICCS)

    NASA Astrophysics Data System (ADS)

    Nett, Brian E.; Tang, Jie; Chen, Guang-Hong

    2010-04-01

    The Prior Image Constrained Compressed Sensing (PICCS) algorithm (Med. Phys. 35, pg. 660, 2008) has been applied to several computed tomography applications with both standard CT systems and flat-panel based systems designed for guiding interventional procedures and radiation therapy treatment delivery. The PICCS algorithm typically utilizes a prior image which is reconstructed via the standard Filtered Backprojection (FBP) reconstruction algorithm. The algorithm then iteratively solves for the image volume that matches the measured data, while simultaneously assuring the image is similar to the prior image. The PICCS algorithm has demonstrated utility in several applications including: improved temporal resolution reconstruction, 4D respiratory phase specific reconstructions for radiation therapy, and cardiac reconstruction from data acquired on an interventional C-arm. One disadvantage of the PICCS algorithm, just as other iterative algorithms, is the long computation times typically associated with reconstruction. In order for an algorithm to gain clinical acceptance reconstruction must be achievable in minutes rather than hours. In this work the PICCS algorithm has been implemented on the GPU in order to significantly reduce the reconstruction time of the PICCS algorithm. The Compute Unified Device Architecture (CUDA) was used in this implementation.

  15. Maximizing Use of Robot-Arm No. 3 in Da Vinci–Assisted Thoracic Surgery

    PubMed Central

    Kajiwara, Naohiro; Maeda, Junichi; Yoshida, Koichi; Kato, Yasufumi; Hagiwara, Masaru; Kakihana, Masatoshi; Ohira, Tatsuo; Kawate, Norihiko; Ikeda, Norihiko

    2015-01-01

    We have previously reported on the importance of appropriate robot-arm settings and replacement of instrument ports in robot-assisted thoracic surgery, because the thoracic cavity requires a large space to access all lesions in various areas of the thoracic cavity from the apex to the diaphragm and mediastinum and the chest wall.1–3 Moreover, it can be difficult to manipulate the da Vinci Surgical System using only arms No. 1 and No. 2 depending on the tumor location. However, arm No. 3 is usually positioned on the same side as arm No. 2, and sometimes it is only used as an assisting-arm to avoid conflict with other arms (Fig. 1). In this report, we show how robot-arm No. 3 can be used with maximum effectiveness in da Vinci-assisted thoracic surgery. PMID:26011219

  16. Design and testing of a model CELSS chamber robot

    NASA Astrophysics Data System (ADS)

    Davis, Mark; Dezego, Shawn; Jones, Kinzy; Kewley, Christopher; Langlais, Mike; McCarthy, John; Penny, Damon; Bonner, Tom; Funderburke, C. Ashley; Hailey, Ruth

    1994-08-01

    A robot system for use in an enclosed environment was designed and tested. The conceptual design will be used to assist in research performed by the Controlled Ecological Life Support System (CELSS) project. Design specifications include maximum load capacity, operation at specified environmental conditions, low maintenance, and safety. The robot system must not be hazardous to the sealed environment, and be capable of stowing and deploying within a minimum area of the CELSS chamber facility. This design consists of a telescoping robot arm that slides vertically on a shaft positioned in the center of the CELSS chamber. The telescoping robot arm consists of a series of links which can be fully extended to a length equal to the radius of the working envelope of the CELSS chamber. The vertical motion of the robot arm is achieved through the use of a combination ball screw/ball spline actuator system. The robot arm rotates cylindrically about the vertical axis through use of a turntable bearing attached to a central mounting structure fitted to the actuator shaft. The shaft is installed in an overhead rail system allowing the entire structure to be stowed and deployed within the CELSS chamber. The overhead rail system is located above the chamber's upper lamps and extends to the center of the CELSS chamber. The mounting interface of the actuator shaft and rail system allows the entire actuator shaft to be detached and removed from the CELSS chamber. When the actuator shaft is deployed, it is held fixed at the bottom of the chamber by placing a square knob on the bottom of the shaft into a recessed square fitting in the bottom of the chamber floor. A support boot ensures the rigidity of the shaft. Three student teams combined into one group designed a model of the CELSS chamber robot that they could build. They investigated materials, availability, and strength in their design. After the model arm and stand were built, the class performed pre-tests on the entire system. A stability pre-test was used to determine whether the model robot arm would tip over on the stand when it was fully extended. Results showed the stand tipped when 50 Newtons were applied horizontally to the top of the vertical shaft while the arm was fully extended.

  17. Design and testing of a model CELSS chamber robot

    NASA Technical Reports Server (NTRS)

    Davis, Mark; Dezego, Shawn; Jones, Kinzy; Kewley, Christopher; Langlais, Mike; Mccarthy, John; Penny, Damon; Bonner, Tom; Funderburke, C. Ashley; Hailey, Ruth

    1994-01-01

    A robot system for use in an enclosed environment was designed and tested. The conceptual design will be used to assist in research performed by the Controlled Ecological Life Support System (CELSS) project. Design specifications include maximum load capacity, operation at specified environmental conditions, low maintenance, and safety. The robot system must not be hazardous to the sealed environment, and be capable of stowing and deploying within a minimum area of the CELSS chamber facility. This design consists of a telescoping robot arm that slides vertically on a shaft positioned in the center of the CELSS chamber. The telescoping robot arm consists of a series of links which can be fully extended to a length equal to the radius of the working envelope of the CELSS chamber. The vertical motion of the robot arm is achieved through the use of a combination ball screw/ball spline actuator system. The robot arm rotates cylindrically about the vertical axis through use of a turntable bearing attached to a central mounting structure fitted to the actuator shaft. The shaft is installed in an overhead rail system allowing the entire structure to be stowed and deployed within the CELSS chamber. The overhead rail system is located above the chamber's upper lamps and extends to the center of the CELSS chamber. The mounting interface of the actuator shaft and rail system allows the entire actuator shaft to be detached and removed from the CELSS chamber. When the actuator shaft is deployed, it is held fixed at the bottom of the chamber by placing a square knob on the bottom of the shaft into a recessed square fitting in the bottom of the chamber floor. A support boot ensures the rigidity of the shaft. Three student teams combined into one group designed a model of the CELSS chamber robot that they could build. They investigated materials, availability, and strength in their design. After the model arm and stand were built, the class performed pre-tests on the entire system. A stability pre-test was used to determine whether the model robot arm would tip over on the stand when it was fully extended. Results showed the stand tipped when 50 Newtons were applied horizontally to the top of the vertical shaft while the arm was fully extended. This proved that it was stable. Another pre-test was the actuator slip test used to determine if there is an adequate coefficient of friction between the actuator drive wheels and drive cable to enable the actuator to fully extend and retract the arm. This pre-test revealed that the coefficient of friction was not large enough to prevent slippage. Sandpaper was glued to the drive wheel and this eliminated the slippage problem. The class preformed a fit test in the CELSS chamber to ensure that the completed robot arm is capable of reaching the entire working envelope. The robot was centered in the chamber and the arm was fully extended to the sides of the chamber. The arm was also able to retract to clear the drain pipes separating the upper and lower plant trays.

  18. Control of a 7-DOF Robotic Arm System With an SSVEP-Based BCI.

    PubMed

    Chen, Xiaogang; Zhao, Bing; Wang, Yijun; Xu, Shengpu; Gao, Xiaorong

    2018-04-12

    Although robot technology has been successfully used to empower people who suffer from motor disabilities to increase their interaction with their physical environment, it remains a challenge for individuals with severe motor impairment, who do not have the motor control ability to move robots or prosthetic devices by manual control. In this study, to mitigate this issue, a noninvasive brain-computer interface (BCI)-based robotic arm control system using gaze based steady-state visual evoked potential (SSVEP) was designed and implemented using a portable wireless electroencephalogram (EEG) system. A 15-target SSVEP-based BCI using a filter bank canonical correlation analysis (FBCCA) method allowed users to directly control the robotic arm without system calibration. The online results from 12 healthy subjects indicated that a command for the proposed brain-controlled robot system could be selected from 15 possible choices in 4[Formula: see text]s (i.e. 2[Formula: see text]s for visual stimulation and 2[Formula: see text]s for gaze shifting) with an average accuracy of 92.78%, resulting in a 15 commands/min transfer rate. Furthermore, all subjects (even naive users) were able to successfully complete the entire move-grasp-lift task without user training. These results demonstrated an SSVEP-based BCI could provide accurate and efficient high-level control of a robotic arm, showing the feasibility of a BCI-based robotic arm control system for hand-assistance.

  19. A cable-driven wrist robotic rehabilitator using a novel torque-field controller for human motion training.

    PubMed

    Chen, Weihai; Cui, Xiang; Zhang, Jianbin; Wang, Jianhua

    2015-06-01

    Rehabilitation technologies have great potentials in assisted motion training for stroke patients. Considering that wrist motion plays an important role in arm dexterous manipulation of activities of daily living, this paper focuses on developing a cable-driven wrist robotic rehabilitator (CDWRR) for motion training or assistance to subjects with motor disabilities. The CDWRR utilizes the wrist skeletal joints and arm segments as the supporting structure and takes advantage of cable-driven parallel design to build the system, which brings the properties of flexibility, low-cost, and low-weight. The controller of the CDWRR is designed typically based on a virtual torque-field, which is to plan "assist-as-needed" torques for the spherical motion of wrist responding to the orientation deviation in wrist motion training. The torque-field controller can be customized to different levels of rehabilitation training requirements by tuning the field parameters. Additionally, a rapidly convergent parameter self-identification algorithm is developed to obtain the uncertain parameters automatically for the floating wearable structure of the CDWRR. Finally, experiments on a healthy subject are carried out to demonstrate the performance of the controller and the feasibility of the CDWRR on wrist motion training or assistance.

  20. [Decisions in case of "problematic" cost-effectiveness ratios based on the example of a clinical trial in rehabilitation care].

    PubMed

    Leidl, R; Jacobi, E; Knab, J; Schweikert, B

    2006-04-01

    Economic assessment of an additional psychological intervention in the rehabilitation of patients with chronic low-back pain and evaluation of results by decision makers. Piggy-back cost-utility analysis of a randomised clinical trial, including a bootstrap analysis. Costs were measured by using the cost accounting systems of the rehabilitation clinics and by surveying patients. Health-related quality of life was measured using the EQ-5D. Implications of different representations of the decision problem and corresponding decision rules concerning the cost-effectiveness plane are discussed. As compared with the 126 patients of the control arm, the 98 patients in the intervention arm gained 3.5 days in perfect health on average as well as 1219 euro cost saving. However, because of the uncertainty involved, the results of a bootstrap analysis cover all quadrants of the cost-effectiveness plane. Using maximum willingness-to-pay per effect unit gained, decision rules can be defined for parts of the cost-effectiveness plane. These have to be aggregated in a further valuation step. Study results show that decisions on stochastic economic evaluation results may require an additional valuation step aggregating the various parts of the cost-effectiveness plane.

  1. A cable-driven wrist robotic rehabilitator using a novel torque-field controller for human motion training

    NASA Astrophysics Data System (ADS)

    Chen, Weihai; Cui, Xiang; Zhang, Jianbin; Wang, Jianhua

    2015-06-01

    Rehabilitation technologies have great potentials in assisted motion training for stroke patients. Considering that wrist motion plays an important role in arm dexterous manipulation of activities of daily living, this paper focuses on developing a cable-driven wrist robotic rehabilitator (CDWRR) for motion training or assistance to subjects with motor disabilities. The CDWRR utilizes the wrist skeletal joints and arm segments as the supporting structure and takes advantage of cable-driven parallel design to build the system, which brings the properties of flexibility, low-cost, and low-weight. The controller of the CDWRR is designed typically based on a virtual torque-field, which is to plan "assist-as-needed" torques for the spherical motion of wrist responding to the orientation deviation in wrist motion training. The torque-field controller can be customized to different levels of rehabilitation training requirements by tuning the field parameters. Additionally, a rapidly convergent parameter self-identification algorithm is developed to obtain the uncertain parameters automatically for the floating wearable structure of the CDWRR. Finally, experiments on a healthy subject are carried out to demonstrate the performance of the controller and the feasibility of the CDWRR on wrist motion training or assistance.

  2. Development and Field Test of the Trial Battery for Project A. Improving the Selection, Classification and Utilization of Army Enlisted Personnel. Project A: Improving the Selection, Classification and Utilization of Army Enlisted Personnel. ARI Technical Report 739.

    ERIC Educational Resources Information Center

    Peterson, Norman G., Ed.

    As part of the United States Army's Project A, research has been conducted to develop and field test a battery of experimental tests to complement the Armed Services Vocational Aptitude Battery in predicting soldiers' job performance. Project A is the United States Army's large-scale manpower effort to improve selection, classification, and…

  3. Identification and classification of upper limb motions using PCA.

    PubMed

    Veer, Karan; Vig, Renu

    2018-03-28

    This paper describes the utility of principal component analysis (PCA) in classifying upper limb signals. PCA is a powerful tool for analyzing data of high dimension. Here, two different input strategies were explored. The first method uses upper arm dual-position-based myoelectric signal acquisition and the other solely uses PCA for classifying surface electromyogram (SEMG) signals. SEMG data from the biceps and the triceps brachii muscles and four independent muscle activities of the upper arm were measured in seven subjects (total dataset=56). The datasets used for the analysis are rotated by class-specific principal component matrices to decorrelate the measured data prior to feature extraction.

  4. Postural stability of sitting women.

    PubMed

    Nag, Pranab K; Vyas, Heer; Nag, Anjali; Pal, Swati

    2013-01-01

    The study examined the utility of stabilometric dimensions and explored whether the changes in sitting postures were manifested in functional measures of postural control. Eleven women participated in the study, which used 11 chair sitting postures: arms on laps or arms right angled; armrest at a height of 17, 20 and 23 cm; with or without backrest; slouch or straight back; legs right angled at knees or crossed legs. The backrest and armrest shifted 16.3% of body weight from a seat pan. The characteristics of stabilometric dimensions evaluated the influence of seat components and sitting behaviour on postural balance. The study attempted to evaluate stability and its application in human-seat interface design.

  5. Bromide, Chloride, and Sulfate Concentrations, and Specific Conductance, Lake Texoma, Texas and Oklahoma, 2007-08

    USGS Publications Warehouse

    Baldys, Stanley

    2009-01-01

    The U.S. Geological Survey, in cooperation with the City of Dallas Water Utilities Division, collected water-quality data from 11 sites on Lake Texoma, a reservoir on the Texas-Oklahoma border, during April 2007-September 2008. At 10 of the sites, physical properties (depth, specific conductance, pH, temperature, dissolved oxygen, and alkalinity) were measured and samples were collected for analysis of selected dissolved constituents (bromide, calcium, magnesium, potassium, sodium, carbonate, bicarbonate, chloride, and sulfate); at one site, only physical properties were measured. The primary constituent of interest was bromide. Bromate can form when ozone is used to disinfect raw water containing bromide, and bromate is a suspected human carcinogen. Chloride and sulfate were of secondary interest. Only the analytical results for bromide, chloride, sulfate, and measured specific conductance are discussed in this report. Median dissolved bromide concentrations ranged from 0.28 to 0.60 milligrams per liter. The largest median dissolved bromide concentration (0.60 milligram per liter at site 11) was from the Red River arm of Lake Texoma. Dissolved bromide concentrations generally were larger in the Red River arm of Lake Texoma than in the Washita arm of the lake. Median dissolved chloride concentrations were largest in the Red River arm of Lake Texoma at site 11 (431 milligrams per liter) and smallest at site 8 (122 milligrams per liter) in the Washita arm. At site 11 in the Red River arm, the mean and median chloride concentrations exceeded the secondary maximum contaminant level of 300 milligrams per liter for chloride established by the 'Texas Surface Water Quality Standards' for surface-water bodies designated for the public water supply use. Median dissolved sulfate concentrations ranged from 182 milligrams per liter at site 4 in the Big Mineral arm to 246 milligrams per liter at site 11 in the Red River arm. None of the mean or median sulfate concentrations exceeded the secondary maximum contaminant level of 300 milligrams per liter. Median specific conductance measurements at sites ranged from 1,120 microsiemens per centimeter at site 8 in the Washita arm to 2,100 microsiemens per centimeter in the Red River arm. The spatial distribution of specific conductance in Lake Texoma was similar to that of bromide and chloride, with larger specific conductance values in the Red River arm compared to those in the Washita arm.

  6. Personnel occupied woven envelope robot

    NASA Technical Reports Server (NTRS)

    Wessling, Francis; Teoh, William; Ziemke, M. Carl

    1988-01-01

    The Personnel Occupied Woven Envelope Robot (POWER) provides an alternative to extravehicular activity (EVA) of space suited astronauts and/or use of long slender manipulator arms such as are used in the Shuttle Remote Manipulator System. POWER provides the capability for a shirt sleeved astronaut to perform such work by entering a control pod through air locks at both ends of an inflated flexible bellows (access tunnel). The exoskeleton of the tunnel is a series of six degrees of freedom (Six-DOF) articulated links compressible to 1/6 of their fully extended length. The operator can maneuver the control pod to almost any location within about 50 m of the base attachment to the space station. POWER can be envisioned as a series of hollow Six-DOF manipulator segments or arms wherein each arm grasps the shoulder of the next arm. Inside the hollow arms ia a bellow-type access tunnel. The control pod is the fist of the series of linked hollow arms. The fingers of the fist are conventional manipulator arms under direct visual control of the nearby operator in the pod. The applications and progress to date of the POWER system is given.

  7. The ARM Data System and Archive

    DOE PAGES

    McCord, Raymond A.; Voyles, Jimmy W.

    2016-07-05

    Every observationally based research program needs a way to collect data from instruments, convert the data from its raw format into a more usable format, apply quality control, process it into higher-order data products, store the data, and make the data available to its scientific community. This data flow is illustrated pictorially in Fig. 11-1. These are the basic requirements of any scientific data system, and ARM’s data system would have to address these requirements and more. This research provides one view of the development of the ARM data system, which includes the ARM Data Archive, and some of themore » notable decisions that were made along the way.« less

  8. Robot arm system for automatic satellite capture and berthing

    NASA Technical Reports Server (NTRS)

    Nishida, Shinichiro; Toriu, Hidetoshi; Hayashi, Masato; Kubo, Tomoaki; Miyata, Makoto

    1994-01-01

    Load control is one of the most important technologies for capturing and berthing free flying satellites by a space robot arm because free flying satellites have different motion rates. The performance of active compliance control techniques depend on the location of the force sensor and the arm's structural compliance. A compliance control technique for the robot arm's structural elasticity and a consideration for an end-effector appropriate for it are presented in this paper.

  9. Impact of direct substitution of arm span length for current standing height in elderly COPD.

    PubMed

    Pothirat, Chaicharn; Chaiwong, Warawut; Phetsuk, Nittaya

    2015-01-01

    Arm span length is related to standing height and has been studied as a substitute for current standing height for predicting lung function parameters. However, it has never been studied in elderly COPD patients. To evaluate the accuracy of substituting arm span length for current standing height in the evaluation of pulmonary function parameters and severity classification in elderly Thai COPD patients. Current standing height and arm span length were measured in COPD patients aged >60 years. Postbronchodilator spirometric parameters, forced vital capacity (FVC), forced expiratory volume in first second (FEV1), and ratio of FEV1/FVC (FEV1%), were used to classify disease severity according to global initiative for chronic obstructive lung disease criteria. Predicted values for each parameter were also calculated separately utilizing current standing height or arm span length measurements. Student's t-tests and chi-squared tests were used to compare differences between the groups. Statistical significance was set at P<0.05. A total of 106 COPD patients with a mean age of 72.1±7.8 years, mean body mass index of 20.6±3.8 kg/m(2), and mean standing height of 156.4±8.3 cm were enrolled. The mean arm span length exceeded mean standing height by 7.7±4.6 cm (164.0±9.0 vs 156.4±8.3 cm, P<0.001), at a ratio of 1.05±0.03. Percentages of both predicted FVC and FEV1 values based on arm span length were significantly lower than those using current standing height (76.6±25.4 vs 61.6±16.8, P<0.001 and 50.8±25.4 vs 41.1±15.3, P<0.001). Disease severity increased in 39.6% (42/106) of subjects using arm span length over current standing height for predicted lung function. Direct substitution of arm span length for current standing height in elderly Thai COPD patients should not be recommended in cases where arm span length exceeds standing height by more than 4 cm.

  10. Randomized controlled trial of a dose consolidation program.

    PubMed

    Delate, Thomas; Fairman, Kathleen A; Carey, Shelly M; Motheral, Brenda R

    2004-01-01

    To evaluate the effectiveness and financial impact of a drug dose consolidation (optimization) program using letter intervention. This pilot program in a large, mid-Atlantic health plan utilized a randomized controlled trial research design. A review of adjudicated pharmacy claims records was performed monthly for 3 consecutive months from November 2002 through February 2003 to identify inefficient (i.e., >once-daily) regimens for any one of 68 dosage strengths of 37 single-source maintenance drugs with once-daily dosing recommendations. Prescribers who had prescribed one or more inefficient regimens were identified and randomized to one of the 2 intervention arms or a control arm. Prescribers in both intervention arms were sent personalized letters with information on their patients. inefficient regimens and suggested dose consolidation options. Patients of prescribers in one intervention arm received a complementary, patient-oriented letter. Pharmacy claims for patients in all arms were examined at 180 days after the date of the letter mailing for conversion to an efficient (once-daily) regimen. Financial modeling analysis calculated net savings as changes in pharmacy expenditures minus administrative costs. A total of 2,614 inefficient regimens, representing 6.7% of claims for the targeted medications, were identified. The rate of consolidation to a suggested dosing option was lower for the Physician Letter arm (7.3%) than for the Physician/Member Letter arm (10.2%) (P = 0.046). Both intervention arms had higher consolidation rates than the Control arm (3.9%) (P = 0.018 and P = 0.000, respectively.). Approximately 30% of the regimens in each study arm were never refilled after being targeted. Financial modeling indicated that a dose consolidation intervention could save 0.03 dollars to 0.07 dollars per member per month (PMPM) in 2003 dollars with full medication compliance but only 0.02 dollars to 0.03 dollars PMPM when savings were calculated with realistic, partial compliance rates. Subanalyses performed at the drug therapy class level revealed few opportunities to justify implementing a dose consolidation program. After taking into consideration program administrative costs, high rates of refill discontinuation, and dose consolidation that occurs naturally without intervention, the results indicated that a letter-based dose consolidation program did not appreciably decrease pharmacy expenditures.

  11. Arm span and ulnar length are reliable and accurate estimates of recumbent length and height in a multiethnic population of infants and children under 6 years of age.

    PubMed

    Forman, Michele R; Zhu, Yeyi; Hernandez, Ladia M; Himes, John H; Dong, Yongquan; Danish, Robert K; James, Kyla E; Caulfield, Laura E; Kerver, Jean M; Arab, Lenore; Voss, Paula; Hale, Daniel E; Kanafani, Nadim; Hirschfeld, Steven

    2014-09-01

    Surrogate measures are needed when recumbent length or height is unobtainable or unreliable. Arm span has been used as a surrogate but is not feasible in children with shoulder or arm contractures. Ulnar length is not usually impaired by joint deformities, yet its utility as a surrogate has not been adequately studied. In this cross-sectional study, we aimed to examine the accuracy and reliability of ulnar length measured by different tools as a surrogate measure of recumbent length and height. Anthropometrics [recumbent length, height, arm span, and ulnar length by caliper (ULC), ruler (ULR), and grid (ULG)] were measured in 1479 healthy infants and children aged <6 y across 8 study centers in the United States. Multivariate mixed-effects linear regression models for recumbent length and height were developed by using ulnar length and arm span as surrogate measures. The agreement between the measured length or height and the predicted values by ULC, ULR, ULG, and arm span were examined by Bland-Altman plots. All 3 measures of ulnar length and arm span were highly correlated with length and height. The degree of precision of prediction equations for length by ULC, ULR, and ULG (R(2) = 0.95, 0.95, and 0.92, respectively) was comparable with that by arm span (R(2) = 0.97) using age, sex, and ethnicity as covariates; however, height prediction by ULC (R(2) = 0.87), ULR (R(2) = 0.85), and ULG (R(2) = 0.88) was less comparable with arm span (R(2) = 0.94). Our study demonstrates that arm span and ULC, ULR, or ULG can serve as accurate and reliable surrogate measures of recumbent length and height in healthy children; however, ULC, ULR, and ULG tend to slightly overestimate length and height in young infants and children. Further testing of ulnar length as a surrogate is warranted in physically impaired or nonambulatory children. © 2014 American Society for Nutrition.

  12. Emergency Severity Index version 4: a valid and reliable tool in pediatric emergency department triage.

    PubMed

    Green, Nicole A; Durani, Yamini; Brecher, Deena; DePiero, Andrew; Loiselle, John; Attia, Magdy

    2012-08-01

    The Emergency Severity Index version 4 (ESI v.4) is the most recently implemented 5-level triage system. The validity and reliability of this triage tool in the pediatric population have not been extensively established. The goals of this study were to assess the validity of ESI v.4 in predicting hospital admission, emergency department (ED) length of stay (LOS), and number of resources utilized, as well as its reliability in a prospective cohort of pediatric patients. The first arm of the study was a retrospective chart review of 780 pediatric patients presenting to a pediatric ED to determine the validity of ESI v.4. Abstracted data included acuity level assigned by the triage nurse using ESI v.4 algorithm, disposition (admission vs discharge), LOS, and number of resources utilized in the ED. To analyze the validity of ESI v.4, patients were divided into 2 groups for comparison: higher-acuity patients (ESI levels 1, 2, and 3) and lower-acuity patients (ESI levels 4 and 5). Pearson χ analysis was performed for categorical variables. For continuous variables, we conducted a comparison of means based on parametric distribution of variables. The second arm was a prospective cohort study to determine the interrater reliability of ESI v.4 among and between pediatric triage (PT) nurses and pediatric emergency medicine (PEM) physicians. Three raters (2 PT nurses and 1 PEM physician) independently assigned triage scores to 100 patients; k and interclass correlation coefficient were calculated among PT nurses and between the primary PT nurses and physicians. In the validity arm, the distribution of ESI score levels among the 780 cases are as follows: ESI 1: 2 (0.25%); ESI 2: 73 (9.4%); ESI 3: 289 (37%); ESI 4: 251 (32%); and ESI 5: 165 (21%). Hospital admission rates by ESI level were 1: 100%, 2: 42%, 3: 14.9%, 4: 1.2%, and 5: 0.6%. The admission rate of the higher-acuity group (76/364, 21%) was significantly greater than the lower-acuity group (4/415, 0.96%), P < 0.001. The mean ED LOS (in minutes) for the higher-acuity group was 257 (SD, 132) versus 143 (SD, 81) in the lower-acuity group, P < 0.001. The higher-acuity group also had significantly greater use of resources than the lower-acuity group, P < 0.001. The percentage of low-acuity patients receiving no resources was 54%, compared with only 26% in the higher-acuity group. Conversely, a greater percentage of higher-acuity patients utilized 2 or more resources than the lower-acuity cohorts, 43% vs 12%, respectively, P < 0.001. In the prospective reliability arm of the study, 15 PT nurses and 8 PEM attending physicians participated in the study; k among nurses was 0.92 and between the primary triage nurses and physicians was 0.78, P < 0.001. The intraclass correlation coefficient was 0.96 for PT nurses and 0.91 between the primary triage nurse and physicians, P < 0.001. Emergency Severity Index v.4 is a valid predictor of hospital admission, ED LOS, and resource utilization in the pediatric ED population. It is a reliable pediatric triage instrument with high agreement among PT nurses and between PT nurses and PEM physicians.

  13. Toward attenuating the impact of arm positions on electromyography pattern-recognition based motion classification in transradial amputees

    PubMed Central

    2012-01-01

    Background Electromyography (EMG) pattern-recognition based control strategies for multifunctional myoelectric prosthesis systems have been studied commonly in a controlled laboratory setting. Before these myoelectric prosthesis systems are clinically viable, it will be necessary to assess the effect of some disparities between the ideal laboratory setting and practical use on the control performance. One important obstacle is the impact of arm position variation that causes the changes of EMG pattern when performing identical motions in different arm positions. This study aimed to investigate the impacts of arm position variation on EMG pattern-recognition based motion classification in upper-limb amputees and the solutions for reducing these impacts. Methods With five unilateral transradial (TR) amputees, the EMG signals and tri-axial accelerometer mechanomyography (ACC-MMG) signals were simultaneously collected from both amputated and intact arms when performing six classes of arm and hand movements in each of five arm positions that were considered in the study. The effect of the arm position changes was estimated in terms of motion classification error and compared between amputated and intact arms. Then the performance of three proposed methods in attenuating the impact of arm positions was evaluated. Results With EMG signals, the average intra-position and inter-position classification errors across all five arm positions and five subjects were around 7.3% and 29.9% from amputated arms, respectively, about 1.0% and 10% low in comparison with those from intact arms. While ACC-MMG signals could yield a similar intra-position classification error (9.9%) as EMG, they had much higher inter-position classification error with an average value of 81.1% over the arm positions and the subjects. When the EMG data from all five arm positions were involved in the training set, the average classification error reached a value of around 10.8% for amputated arms. Using a two-stage cascade classifier, the average classification error was around 9.0% over all five arm positions. Reducing ACC-MMG channels from 8 to 2 only increased the average position classification error across all five arm positions from 0.7% to 1.0% in amputated arms. Conclusions The performance of EMG pattern-recognition based method in classifying movements strongly depends on arm positions. This dependency is a little stronger in intact arm than in amputated arm, which suggests that the investigations associated with practical use of a myoelectric prosthesis should use the limb amputees as subjects instead of using able-body subjects. The two-stage cascade classifier mode with ACC-MMG for limb position identification and EMG for limb motion classification may be a promising way to reduce the effect of limb position variation on classification performance. PMID:23036049

  14. Reduced activation in the ventral striatum during probabilistic decision-making in patients in an at-risk mental state

    PubMed Central

    Rausch, Franziska; Mier, Daniela; Eifler, Sarah; Fenske, Sabrina; Schirmbeck, Frederike; Englisch, Susanne; Schilling, Claudia; Meyer-Lindenberg, Andreas; Kirsch, Peter; Zink, Mathias

    2015-01-01

    Background Patients with schizophrenia display metacognitive impairments, such as hasty decision-making during probabilistic reasoning — the “jumping to conclusion” bias (JTC). Our recent fMRI study revealed reduced activations in the right ventral striatum (VS) and the ventral tegmental area (VTA) to be associated with decision-making in patients with schizophrenia. It is unclear whether these functional alterations occur in the at-risk mental state (ARMS). Methods We administered the classical beads task and fMRI among ARMS patients and healthy controls matched for age, sex, education and premorbid verbal intelligence. None of the ARMS patients was treated with antipsychotics. Both tasks request probabilistic decisions after a variable amount of stimuli. We evaluated activation during decision-making under certainty versus uncertainty and the process of final decision-making. Results We included 24 AMRS patients and 24 controls in our study. Compared with controls, ARMS patients tended to draw fewer beads and showed significantly more JTC bias in the classical beads task, mirroring findings in patients with schizophrenia. During fMRI, ARMS patients did not demonstrate JTC bias on the behavioural level, but showed a significant hypoactivation in the right VS during the decision stage. Limitations Owing to the cross-sectional design of the study, results are constrained to a better insight into the neurobiology of risk constellations, but not pre-psychotic stages. Nine of the ARMS patients were treated with antidepressants and/or lorazepam. Conclusion As in patients with schizophrenia, a striatal hypoactivation was found in ARMS patients. Confounding effects of antipsychotic medication can be excluded. Our findings indicate that error prediction signalling and reward anticipation may be linked to striatal dysfunction during prodromal stages and should be examined for their utility in predicting transition risk. PMID:25622039

  15. Use of the DEKA Arm for amputees with brachial plexus injury: A case series.

    PubMed

    Resnik, Linda; Fantini, Christopher; Latlief, Gail; Phillips, Samuel; Sasson, Nicole; Sepulveda, Eve

    2017-01-01

    Patients with upper limb amputation and brachial plexus injuries have high rates of prosthesis rejection. Study purpose is to describe experiences of subjects with transhumeral amputation and brachial plexus injury, who were fit with, and trained to use, a DEKA Arm. This was a mixed-methods study utilizing qualitative (e.g. interview, survey) and quantitative data (e.g. self-report and performance measures). Subject 1, a current prosthesis user, had a shoulder arthrodesis. Subject 2, not a prosthesis user, had a subluxed shoulder. Both were trained in laboratory and participated in a trial of home use. Descriptive analyses of processes and outcomes were conducted. Subject 1 was fitted with the transhumeral configuration (HC) DEKA Arm using a compression release stabilized socket. He had 12 hours of prosthetic training and participated in all home study activities. Subject 1 had improved dexterity and prosthetic satisfaction with the DEKA Arm and reported better quality of life (QOL) at the end of participation. Subject 2 was fit with the shoulder configuration (SC) DEKA Arm using a modified X-frame socket. He had 30 hours of training and participated in 3 weeks of home activities. He reported less functional disability at the end of training as compared to baseline, but encountered personal problems and exacerbation of PTSD symptoms and withdrew from home use portion at 3 weeks. Both subjects reported functional benefits from use, and expressed a desire to receive a DEKA Arm in the future. This paper reported on two different strategies for prosthetic fitting and their outcomes. The advantages and limitations of each approach were discussed. Use of both the HC and SC DEKA Arm for patients with TH amputation and brachial plexus injury was reported. Lessons learned may be instructive to clinicians considering prosthetic choices for future cases.

  16. Reduced activation in the ventral striatum during probabilistic decision-making in patients in an at-risk mental state.

    PubMed

    Rausch, Franziska; Mier, Daniela; Eifler, Sarah; Fenske, Sabrina; Schirmbeck, Frederike; Englisch, Susanne; Schilling, Claudia; Meyer-Lindenberg, Andreas; Kirsch, Peter; Zink, Mathias

    2015-05-01

    Patients with schizophrenia display metacognitive impairments, such as hasty decision-making during probabilistic reasoning - the "jumping to conclusion" bias (JTC). Our recent fMRI study revealed reduced activations in the right ventral striatum (VS) and the ventral tegmental area (VTA) to be associated with decision-making in patients with schizophrenia. It is unclear whether these functional alterations occur in the at-risk mental state (ARMS). We administered the classical beads task and fMRI among ARMS patients and healthy controls matched for age, sex, education and premorbid verbal intelligence. None of the ARMS patients was treated with antipsychotics. Both tasks request probabilistic decisions after a variable amount of stimuli. We evaluated activation during decision-making under certainty versus uncertainty and the process of final decision-making. We included 24 AMRS patients and 24 controls in our study. Compared with controls, ARMS patients tended to draw fewer beads and showed significantly more JTC bias in the classical beads task, mirroring findings in patients with schizophrenia. During fMRI, ARMS patients did not demonstrate JTC bias on the behavioural level, but showed a significant hypoactivation in the right VS during the decision stage. Owing to the cross-sectional design of the study, results are constrained to a better insight into the neurobiology of risk constellations, but not prepsychotic stages. Nine of the ARMS patients were treated with antidepressants and/or lorazepam. As in patients with schizophrenia, a striatal hypoactivation was found in ARMS patients. Confounding effects of antipsychotic medication can be excluded. Our findings indicate that error prediction signalling and reward anticipation may be linked to striatal dysfunction during prodromal stages and should be examined for their utility in predicting transition risk.

  17. Automating arm movement training following severe stroke: functional exercises with quantitative feedback in a gravity-reduced environment.

    PubMed

    Sanchez, Robert J; Liu, Jiayin; Rao, Sandhya; Shah, Punit; Smith, Robert; Rahman, Tariq; Cramer, Steven C; Bobrow, James E; Reinkensmeyer, David J

    2006-09-01

    An important goal in rehabilitation engineering is to develop technology that allows individuals with severe motor impairment to practice arm movement without continuous supervision from a rehabilitation therapist. This paper describes the development of such a system, called Therapy WREX or ("T-WREX"). The system consists of an orthosis that assists in arm movement across a large workspace, a grip sensor that detects hand grip pressure, and software that simulates functional activities. The arm orthosis is an instrumented, adult-sized version of the Wilmington Robotic Exoskeleton (WREX), which is a five degrees-of-freedom mechanism that passively counterbalances the weight of the arm using elastic bands. After providing a detailed design description of T-WREX, this paper describes two pilot studies of the system's capabilities. The first study demonstrated that individuals with chronic stroke whose arm function is compromised in a normal gravity environment can perform reaching and drawing movements while using T-WREX. The second study demonstrated that exercising the affected arm of five people with chronic stroke with T-WREX over an eight week period improved unassisted movement ability (mean change in Fugl-Meyer score was 5 points +/- 2 SD; mean change in range of motion of reaching was 10%, p < 0.001). These results demonstrate the feasibility of automating upper-extremity rehabilitation therapy for people with severe stroke using passive gravity assistance, a grip sensor, and simple virtual reality software.

  18. The genotyping of infectious bronchitis virus in Taiwan by a multiplex amplification refractory mutation system reverse transcription polymerase chain reaction.

    PubMed

    Huang, Shr-Wei; Ho, Chia-Fang; Chan, Kun-Wei; Cheng, Min-Chung; Shien, Jui-Hung; Liu, Hung-Jen; Wang, Chi-Young

    2014-11-01

    Infectious bronchitis virus (IBV; Avian coronavirus) causes acute respiratory and reproductive and urogenital diseases in chickens. Following sequence alignment of IBV strains, a combination of selective primer sets was designed to individually amplify the IBV wild-type and vaccine strains using a multiplex amplification refractory mutation system reverse transcription polymerase chain reaction (ARMS RT-PCR) approach. This system was shown to discriminate the IBV wild-type and vaccine strains. Moreover, an ARMS real-time RT-PCR (ARMS qRT-PCR) was combined with a high-resolution analysis (HRMA) to establish a melt curve analysis program. The specificity of the ARMS RT-PCR and the ARMS qRT-PCR was verified using unrelated avian viruses. Different melting temperatures and distinct normalized and shifted melting curve patterns for the IBV Mass, IBV H120, IBV TW-I, and IBV TW-II strains were detected. The new assays were used on samples of lung and trachea as well as virus from allantoic fluid and cell culture. In addition to being able to detect the presence of IBV vaccine and wild-type strains by ARMS RT-PCR, the IBV Mass, IBV H120, IBV TW-I, and IBV TW-II strains were distinguished using ARMS qRT-PCR by their melting temperatures and by HRMA. These approaches have acceptable sensitivities and specificities and therefore should be able to serve as options when carrying out differential diagnosis of IBV in Taiwan and China. © 2014 The Author(s).

  19. Modified Denavit-Hartenberg parameters for better location of joint axis systems in robot arms

    NASA Technical Reports Server (NTRS)

    Barker, L. K.

    1986-01-01

    The Denavit-Hartenberg parameters define the relative location of successive joint axis systems in a robot arm. A recent justifiable criticism is that one of these parameters becomes extremely large when two successive joints have near-parallel rotational axes. Geometrically, this parameter then locates a joint axis system at an excessive distance from the robot arm and, computationally, leads to an ill-conditioned transformation matrix. In this paper, a simple modification (which results from constraining a transverse vector between successive joint rotational axes to be normal to one of the rotational axes, instead of both) overcomes this criticism and favorably locates the joint axis system. An example is given for near-parallel rotational axes of the elbow and shoulder joints in a robot arm. The regular and modified parameters are extracted by an algebraic method with simulated measurement data. Unlike the modified parameters, extracted values of the regular parameters are very sensitive to measurement accuracy.

  20. KSC-04pd1672

    NASA Image and Video Library

    2004-08-23

    KENNEDY SPACE CENTER, FLA. - The Remote Manipulator System (RMS), also known as the Canadian robotic arm, for the orbiter Discovery has arrived at KSC’s Vehicle Assembly Building Lab. Seen on the left end is the shoulder pitch joint. The wrist and shoulder joints on the RMS allow the basic structure of the arm to maneuver similar to a human arm. The RMS is used to deploy and retrieve payloads, provide a mobile extension ladder or foot restraints for crew members during extravehicular activities; and to aid the flight crew members in viewing surfaces of the orbiter or payloads through a television camera on the RMS. The arm is also serving as the base for the new Orbiter Boom Sensor System (OBSS), one of the safety measures for Return to Flight, equipping the Shuttle with cameras and laser systems to inspect the Shuttle’s Thermal Protection System while in space. Discovery is scheduled for a launch planning window of March 2005 on mission STS-114.

  1. The effects of additional arm weights on arm-swing magnitude and gait patterns in Parkinson's disease.

    PubMed

    Yoon, Jiyeon; Park, Jinse; Park, Kunbo; Jo, Geunyeol; Kim, Haeyu; Jang, Wooyoung; Kim, Ji Sun; Youn, Jinyoung; Oh, Eung Seok; Kim, Hee-Tae; Youm, Chang Hong

    2016-01-01

    Recently, arm facilitation has been interested in gait rehabilitation. However, there have been few studies concerning arm facilitation in patients with Parkinson's disease (PD). The aim of our study was to investigate the effect of increasing arm weights on gait pattern in patients with PD. Twenty-seven patients with PD were enrolled, and they underwent gait analysis using a three-dimensional motion capture system. Sandbags were applied to the distal forearms in all participants. We compared gait parameters including arm swing, pelvic motion, spatiotemporal data, and relative rotational angle between the weighted and unweighted gaits. The total arm-swing amplitude and pelvic rotation were significantly higher when walking with additional arm weights than without arm weights. Cadence, walking speed, stride length, and swing phase were significantly higher, whereas stride time, double-support time, and stance phase were significantly lower, when walking with additional arm weights than without arm weights. We conclude that adding weights to the arm during walking may facilitate arm and pelvic movements, which results in changes to gait patterns. The therapeutic use of additional arm weights could be considered for gait rehabilitation in PD to improve gait impairment. Arm-swing facilitation using weight load improved gait in Parkinson's disease. Copyright © 2015 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  2. An embedded real-time red peach detection system based on an OV7670 camera, ARM cortex-M4 processor and 3D look-up tables.

    PubMed

    Teixidó, Mercè; Font, Davinia; Pallejà, Tomàs; Tresanchez, Marcel; Nogués, Miquel; Palacín, Jordi

    2012-10-22

    This work proposes the development of an embedded real-time fruit detection system for future automatic fruit harvesting. The proposed embedded system is based on an ARM Cortex-M4 (STM32F407VGT6) processor and an Omnivision OV7670 color camera. The future goal of this embedded vision system will be to control a robotized arm to automatically select and pick some fruit directly from the tree. The complete embedded system has been designed to be placed directly in the gripper tool of the future robotized harvesting arm. The embedded system will be able to perform real-time fruit detection and tracking by using a three-dimensional look-up-table (LUT) defined in the RGB color space and optimized for fruit picking. Additionally, two different methodologies for creating optimized 3D LUTs based on existing linear color models and fruit histograms were implemented in this work and compared for the case of red peaches. The resulting system is able to acquire general and zoomed orchard images and to update the relative tracking information of a red peach in the tree ten times per second.

  3. An Embedded Real-Time Red Peach Detection System Based on an OV7670 Camera, ARM Cortex-M4 Processor and 3D Look-Up Tables

    PubMed Central

    Teixidó, Mercè; Font, Davinia; Pallejà, Tomàs; Tresanchez, Marcel; Nogués, Miquel; Palacín, Jordi

    2012-01-01

    This work proposes the development of an embedded real-time fruit detection system for future automatic fruit harvesting. The proposed embedded system is based on an ARM Cortex-M4 (STM32F407VGT6) processor and an Omnivision OV7670 color camera. The future goal of this embedded vision system will be to control a robotized arm to automatically select and pick some fruit directly from the tree. The complete embedded system has been designed to be placed directly in the gripper tool of the future robotized harvesting arm. The embedded system will be able to perform real-time fruit detection and tracking by using a three-dimensional look-up-table (LUT) defined in the RGB color space and optimized for fruit picking. Additionally, two different methodologies for creating optimized 3D LUTs based on existing linear color models and fruit histograms were implemented in this work and compared for the case of red peaches. The resulting system is able to acquire general and zoomed orchard images and to update the relative tracking information of a red peach in the tree ten times per second. PMID:23202040

  4. The rotate-plus-shift C-arm trajectory. Part I. Complete data with less than 180° rotation.

    PubMed

    Ritschl, Ludwig; Kuntz, Jan; Fleischmann, Christof; Kachelrieß, Marc

    2016-05-01

    In the last decade, C-arm-based cone-beam CT became a widely used modality for intraoperative imaging. Typically a C-arm CT scan is performed using a circular or elliptical trajectory around a region of interest. Therefore, an angular range of at least 180° plus fan angle must be covered to ensure a completely sampled data set. However, mobile C-arms designed with a focus on classical 2D applications like fluoroscopy may be limited to a mechanical rotation range of less than 180° to improve handling and usability. The method proposed in this paper allows for the acquisition of a fully sampled data set with a system limited to a mechanical rotation range of at least 180° minus fan angle using a new trajectory design. This enables CT like 3D imaging with a wide range of C-arm devices which are mainly designed for 2D imaging. The proposed trajectory extends the mechanical rotation range of the C-arm system with two additional linear shifts. Due to the divergent character of the fan-beam geometry, these two shifts lead to an additional angular range of half of the fan angle. Combining one shift at the beginning of the scan followed by a rotation and a second shift, the resulting rotate-plus-shift trajectory enables the acquisition of a completely sampled data set using only 180° minus fan angle of rotation. The shifts can be performed using, e.g., the two orthogonal positioning axes of a fully motorized C-arm system. The trajectory was evaluated in phantom and cadaver examinations using two prototype C-arm systems. The proposed trajectory leads to reconstructions without limited angle artifacts. Compared to the limited angle reconstructions of 180° minus fan angle, image quality increased dramatically. Details in the rotate-plus-shift reconstructions were clearly depicted, whereas they are dominated by artifacts in the limited angle scan. The method proposed here employs 3D imaging using C-arms with less than 180° rotation range adding full 3D functionality to a C-arm device retaining both handling comfort and the usability of 2D imaging. This method has a clear potential for clinical use especially to meet the increasing demand for an intraoperative 3D imaging.

  5. The rotate-plus-shift C-arm trajectory. Part I. Complete data with less than 180° rotation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ritschl, Ludwig; Fleischmann, Christof; Kuntz, Jan, E-mail: j.kuntz@dkfz.de

    Purpose: In the last decade, C-arm-based cone-beam CT became a widely used modality for intraoperative imaging. Typically a C-arm CT scan is performed using a circular or elliptical trajectory around a region of interest. Therefore, an angular range of at least 180° plus fan angle must be covered to ensure a completely sampled data set. However, mobile C-arms designed with a focus on classical 2D applications like fluoroscopy may be limited to a mechanical rotation range of less than 180° to improve handling and usability. The method proposed in this paper allows for the acquisition of a fully sampled datamore » set with a system limited to a mechanical rotation range of at least 180° minus fan angle using a new trajectory design. This enables CT like 3D imaging with a wide range of C-arm devices which are mainly designed for 2D imaging. Methods: The proposed trajectory extends the mechanical rotation range of the C-arm system with two additional linear shifts. Due to the divergent character of the fan-beam geometry, these two shifts lead to an additional angular range of half of the fan angle. Combining one shift at the beginning of the scan followed by a rotation and a second shift, the resulting rotate-plus-shift trajectory enables the acquisition of a completely sampled data set using only 180° minus fan angle of rotation. The shifts can be performed using, e.g., the two orthogonal positioning axes of a fully motorized C-arm system. The trajectory was evaluated in phantom and cadaver examinations using two prototype C-arm systems. Results: The proposed trajectory leads to reconstructions without limited angle artifacts. Compared to the limited angle reconstructions of 180° minus fan angle, image quality increased dramatically. Details in the rotate-plus-shift reconstructions were clearly depicted, whereas they are dominated by artifacts in the limited angle scan. Conclusions: The method proposed here employs 3D imaging using C-arms with less than 180° rotation range adding full 3D functionality to a C-arm device retaining both handling comfort and the usability of 2D imaging. This method has a clear potential for clinical use especially to meet the increasing demand for an intraoperative 3D imaging.« less

  6. A real-time robot arm collision avoidance system

    NASA Technical Reports Server (NTRS)

    Shaffer, Clifford A.; Herb, Gregory M.

    1992-01-01

    A data structure and update algorithm are presented for a prototype real-time collision avoidance safety system simulating a multirobot workspace. The data structure is a variant of the octree, which serves as a spatial index. An octree recursively decomposes 3D space into eight equal cubic octants until each octant meets some decomposition criteria. The N-objects octree, which indexes a collection of 3D primitive solids is used. These primitives make up the two (seven-degrees-of-freedom) robot arms and workspace modeled by the system. As robot arms move, the octree is updated to reflect their changed positions. During most update cycles, any given primitive does not change which octree nodes it is in. Thus, modification to the octree is rarely required. Cycle time for interpreting current arm joint angles, updating the octree to reflect new positions, and detecting/reporting imminent collisions averages 30 ms on an Intel 80386 processor running at 20 MHz.

  7. [The "martin-arm" system for abdominal wall fixation for many applications - experience from its use of gynaecology (author's transl)].

    PubMed

    Müller, H G

    1979-01-01

    The "martin-arm"-System meets the demand for optimal fixation of outer edges of the wound cavity and exact positioning of organs in a three dimensional manner at abdominal operations. The four joints of each arm individually connected to the Op-table make this possible. They are fixed in position by a central joint with a lever which can be tightened. An adequate assortment of exchangeable retractors, specula and spatulas offers the possibility of a clear view of the operation. All instruments are ready for use even without the "martin-Arm". This system is especially suitable for emergency surgery, for small gynaecology wards or during staff shortages e.g. at night. The operation setting, according to requirements, remains in position for the duration of the whole operation. In the case of long operations, fatigue symptoms of the assistant are no longer present with this instrumentation.

  8. Impact of electronic coupling, symmetry, and planarization on one- and two-photon properties of triarylamines with one, two, or three diarylboryl acceptors.

    PubMed

    Makarov, Nikolay S; Mukhopadhyay, Sukrit; Yesudas, Kada; Brédas, Jean-Luc; Perry, Joseph W; Pron, Agnieszka; Kivala, Milan; Müllen, Klaus

    2012-04-19

    We have performed a study of the one- and two-photon absorption properties of a systematically varied series of triarylamino-compounds with one, two, or three attached diarylborane arms arranged in linear dipolar, bent dipolar, and octupolar geometries. Two-photon fluorescence excitation spectra were measured over a wide spectral range with femtosecond laser pulses. We found that on going from the single-arm to the two- and three-arm systems, the peak in two-photon absorption (2PA) cross-section is suppressed by factors of 3-11 for the lowest excitonic level associated with the electronic coupling of the arms, whereas it is enhanced by factors of 4-8 for the higher excitonic level. These results show that the coupling of arms redistributes the 2PA cross-section between the excitonic levels in a manner that strongly favors the higher-energy excitonic level. The experimental data on one- and two-photon cross-sections, ground- and excited-state transition dipole moments, and permanent dipole moment differences between the ground and the lowest excited states were compared to the results obtained from a simple Frenkel exciton model and from highly correlated quantum-chemical calculations. It has been found that planarization of the structure around the triarylamine moiety leads to a sizable increase in peak 2PA cross-section for the lowest excitonic level of the two-arm system, whereas for the three-arm system, the corresponding peak was weakened and shifted to lower energy. Our studies show the importance of the interarm coupling, number of arms, and structural planarity on both the enhancement and the suppression of two-photon cross-sections in multiarm molecules. © 2012 American Chemical Society

  9. Selection, training and retention of an armed private security department.

    PubMed

    Hollar, David B

    2009-01-01

    To arm or not to arm security officers? One hospital which has opted for arming its officers is Cook Children's Healthcare System, Fort Worth, TX, an integrated pediatric healthcare facility with over 4000 employees. Because of its location in a major metropolitan area and based on several factors including demographics, exterior risk assessments and crime statistics, the hospital's Administration and its Risk Manager supported the decision to operate as an armed security force, according to the author. In this article he shares its current program and presents some thoughts and ideas that may benefit others who are considering this important step.

  10. Associations between socio-demographic characteristics and chemical concentrations contributing to cumulative exposures in the United States

    EPA Science Inventory

    Association rule mining (ARM) has been widely used to identify associations between various entities in many fields. Although some studies have utilized it to analyze the relationship between chemicals and human health effects, fewer have used this technique to identify and quant...

  11. Flexible arms provide constant force for pressure switch calibration

    NASA Technical Reports Server (NTRS)

    Cain, D. E.; Kunz, R. W.

    1966-01-01

    In-place calibration of a pressure switch is provided by a system of radially oriented flexing arms which, when rotated at a known velocity, convert the centrifugal force of the arms to a linear force along the shaft. The linear force, when applied to a pressure switch diaphragm, can then be calculated.

  12. 78 FR 699 - 36(b)(1) Arms Sales Notification

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-04

    ... proposed sale of this system will not alter the basic military balance in the region. The principal... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 12-02] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...

  13. Floor Plans Engine Removal Platform, Hold Down Arm Platform, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Floor Plans - Engine Removal Platform, Hold Down Arm Platform, Hydraulic Equipment Platforms, Isometric Cutaway of Engine Removal Platform, Isometric Cutaway of Hold Down Arm Platform, Isometric Cutaway of Hydraulic Platforms and Engine Support System Access - Marshall Space Flight Center, Saturn V S-IC Static Test Facility, West Test Area, Huntsville, Madison County, AL

  14. Movement Structure in Young and Elderly Adults during Goal-Directed Movements of the Left and Right Arm

    ERIC Educational Resources Information Center

    Poston, Brach; Van Gemmert, Arend W. A.; Barduson, Beth; Stelmach, George E.

    2009-01-01

    Elderly adults often exhibit performance deficits during goal-directed movements of the dominant arm compared with young adults. Recent studies involving hemispheric lateralization have provided evidence that the dominant and non-dominant hemisphere-arm systems are specialized for controlling different movement parameters and that hemispheric…

  15. Modal Parameter Identification of a Flexible Arm System

    NASA Technical Reports Server (NTRS)

    Barrington, Jason; Lew, Jiann-Shiun; Korbieh, Edward; Wade, Montanez; Tantaris, Richard

    1998-01-01

    In this paper an experiment is designed for the modal parameter identification of a flexible arm system. This experiment uses a function generator to provide input signal and an oscilloscope to save input and output response data. For each vibrational mode, many sets of sine-wave inputs with frequencies close to the natural frequency of the arm system are used to excite the vibration of this mode. Then a least-squares technique is used to analyze the experimental input/output data to obtain the identified parameters for this mode. The identified results are compared with the analytical model obtained by applying finite element analysis.

  16. The development of a general purpose ARM-based processing unit for the ATLAS TileCal sROD

    NASA Astrophysics Data System (ADS)

    Cox, M. A.; Reed, R.; Mellado, B.

    2015-01-01

    After Phase-II upgrades in 2022, the data output from the LHC ATLAS Tile Calorimeter will increase significantly. ARM processors are common in mobile devices due to their low cost, low energy consumption and high performance. It is proposed that a cost-effective, high data throughput Processing Unit (PU) can be developed by using several consumer ARM processors in a cluster configuration to allow aggregated processing performance and data throughput while maintaining minimal software design difficulty for the end-user. This PU could be used for a variety of high-level functions on the high-throughput raw data such as spectral analysis and histograms to detect possible issues in the detector at a low level. High-throughput I/O interfaces are not typical in consumer ARM System on Chips but high data throughput capabilities are feasible via the novel use of PCI-Express as the I/O interface to the ARM processors. An overview of the PU is given and the results for performance and throughput testing of four different ARM Cortex System on Chips are presented.

  17. Precipitation Estimation from the ARM Distributed Radar Network During the MC3E Campaign

    NASA Astrophysics Data System (ADS)

    Theisen, A. K.; Giangrande, S. E.; Collis, S. M.

    2012-12-01

    The DOE - NASA Midlatitude Continental Convective Cloud Experiment (MC3E) was the first demonstration of the Atmospheric Radiation Measurement (ARM) Climate Research Facility scanning precipitation radar platforms. A goal for the MC3E field campaign over the Southern Great Plains (SGP) facility was to demonstrate the capabilities of ARM polarimetric radar systems for providing unique insights into deep convective storm evolution and microphysics. One practical application of interest for climate studies and the forcing of cloud resolving models is improved Quantitative Precipitation Estimates (QPE) from ARM radar systems positioned at SGP. This study presents the results of ARM radar-based precipitation estimates during the 2-month MC3E campaign. Emphasis is on the usefulness of polarimetric C-band radar observations (CSAPR) for rainfall estimation to distances within 100 km of the Oklahoma SGP facility. Collocated ground disdrometer resources, precipitation profiling radars and nearby surface Oklahoma Mesonet gauge records are consulted to evaluate potential ARM radar-based rainfall products and optimal methods. Rainfall products are also evaluated against the regional NEXRAD-standard observations.

  18. Decadal Vision Progress Report Implementation Plans and Status for the Next Generation ARM Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mather, James

    The reconfiguration of the ARM facility, formally initiated in early 2014, is geared toward implementing the Next Generation of the ARM Facility, which will more tightly link ARM measurements and atmospheric models. The strategy is outlined in the ARM Climate Research Facility Decadal Vision (DOE 2014a). The strategy includes the implementation of a high-resolution model, initially at the Southern Great Plains (SGP) site, and enhancements at the SGP and North Slope of Alaska (NSA) sites to provide additional observations to support modeling and process studies. Enhancements at the SGP site focus on ground-based instruments while enhancements at the NSA makemore » use of Unmanned Aerial Systems (UAS) and Tethered Balloon Systems (TBS). It is also recognized that new data tools and data products will need to be developed to take full advantage of these improvements. This document provides an update on the status of these ARM facility enhancements, beginning with the measurement enhancements at the SGP and NSA, followed by a discussion of the modeling project including associated data-processing activities.« less

  19. Design considerations for an astronaut monorail system for large space structures and the structural characterization of its positioning arm

    NASA Astrophysics Data System (ADS)

    Watson, Judith J.

    1992-08-01

    An astronaut monorail system (AMS) is presented as a vehicle to transport and position EVA astronauts along large space truss structures. The AMS is proposed specifically as an alternative to the crew and equipment transfer aid for Space Station Freedom. Design considerations for the AMS were discussed and a reference configuration was selected for the study. Equations were developed to characterize the stiffness and frequency behavior of the AMS positioning arm. Experimental data showed that these equations gave a fairly accurate representation of the stiffness and frequency behavior of the arm. A study was presented to show trends for the arm behavior based on varying parameters of the stiffness and frequency equations. An ergonomics study was conducted to provide boundary conditions for tolerable frequency and deflection to be used in developing a design concept for the positioning arm. The feasibility of the AMS positioning arm was examined using equations and working curves developed in this study. It was found that a positioning arm of a length to reach all interior points of the space station truss structure could not be designed to satisfy frequency and deflection constraints. By relaxing the design requirements and the ergonomic boundaries, an arm could be designed which would provide a stable work platform for the EVA astronaut and give him access to over 75 percent of the truss interior.

  20. The ARAMIS project: a concept robot and technical design.

    PubMed

    Colizzi, Lucio; Lidonnici, Antonio; Pignolo, Loris

    2009-11-01

    To describe the ARAMIS (Automatic Recovery Arm Motility Integrated System) project, a concept robot applicable in the neuro-rehabilitation of the paretic upper limb after stroke. Methods, results and conclusion: The rationale and engineering of a state-of-the-art, hardware/software integrated robot system, its mechanics, ergonomics, electric/electronics features providing control, safety and suitability of use are described. An ARAMIS prototype has been built and is now available for clinical tests. It allows the therapist to design neuro-rehabilitative (synchronous or asynchronous) training protocols in which sample exercises are generated by a single exoskeleton (operated by the patient's unaffected arm or by the therapist's arm) and mirrored in real-time or offline by the exoskeleton supporting the paretic arm.

  1. Evaluating Suit Fit Using Performance Degradation

    NASA Technical Reports Server (NTRS)

    Margerum, Sarah E.; Cowley, Matthew; Harvill, Lauren; Benson, Elizabeth; Rajulu, Sudhakar

    2012-01-01

    The Mark III planetary technology demonstrator space suit can be tailored to an individual by swapping the modular components of the suit, such as the arms, legs, and gloves, as well as adding or removing sizing inserts in key areas. A method was sought to identify the transition from an ideal suit fit to a bad fit and how to quantify this breakdown using a metric of mobility-based human performance data. To this end, the degradation of the range of motion of the elbow and wrist of the suit as a function of suit sizing modifications was investigated to attempt to improve suit fit. The sizing range tested spanned optimal and poor fit and was adjusted incrementally in order to compare each joint angle across five different sizing configurations. Suited range of motion data were collected using a motion capture system for nine isolated and functional tasks utilizing the elbow and wrist joints. A total of four subjects were tested with motions involving both arms simultaneously as well as the right arm by itself. Findings indicated that no single joint drives the performance of the arm as a function of suit size; instead it is based on the interaction of multiple joints along a limb. To determine a size adjustment range where an individual can operate the suit at an acceptable level, a performance detriment limit was set. This user-selected limit reveals the task-dependent tolerance of the suit fit around optimal size. For example, the isolated joint motion indicated that the suit can deviate from optimal by as little as -0.6 in to -2.6 in before experiencing a 10% performance drop in the wrist or elbow joint. The study identified a preliminary method to quantify the impact of size on performance and developed a new way to gauge tolerances around optimal size.

  2. Coriolus versicolor (Yunzhi) Use as Therapy in Advanced Hepatocellular Carcinoma Patients with Poor Liver Function or Who Are Unfit for Standard Therapy.

    PubMed

    Chay, Wen Yee; Tham, Chee Kian; Toh, Han Chong; Lim, Hwee Yong; Tan, Chee Kiat; Lim, Cindy; Wang, Who-Whong; Choo, Su-Pin

    2017-08-01

    The majority of patients with hepatocellular carcinoma (HCC) are inoperable and results with conventional chemotherapy are dismal. Many end up with no treatment options and resort to alternative medicine. The authors report the use of Coriolus versicolor (CV) in advanced HCC patients with poor liver function or who were unfit to receive standard therapy. Fifteen eligible cases were randomized 2:1 to either CV or placebo. The primary endpoint was the median time to progression (TTP) between both arms. Secondary endpoints include evaluating response rates, toxicity, quality of life (QOL), progression-free survival (PFS), and overall survival (OS). Further correlative studies were performed looking at the effect of CV on the immune system. The median treatment duration was 1.5 cycles and 3 cycles on the placebo and CV arm, respectively. Median TTP was 2.5 (1.4-5.3) months compared to 4.2 (0.4-4.2) months in the CV and placebo arm, respectively, hazard ratio (HR) 0.70 (0.16-3.05 p = 0.634). Median PFS was 2.5 (1.4-5.3) months in the CV and 1.1 (0.4-4.2) months in the placebo arm, HR 0.42 (0.13-1.34, p = 0.144). Median OS was 6.5 (3.3-24.1) and 2.2 (0.8-23.3) months, respectively, HR 0.35 (0.10-1.25, p = 0.105). Social and emotional functioning scores were higher in the CV group compared to placebo group on treatment. CV subjects had less appetite loss and pain symptoms compared to placebo subjects during treatment. There was no difference in TTP with use of CV compared to placebo. CV subjects generally had better QOL on treatment compared to placebo subjects. The utility of this supplement in patients whose primary treatment goal is palliation should be further explored.

  3. A randomized, placebo-controlled trial of repetitive spinal magnetic stimulation in lumbosacral spondylotic pain.

    PubMed

    Lo, Yew L; Fook-Chong, Stephanie; Huerto, Antonio P; George, Jane M

    2011-07-01

    Lumbar spondylosis is a degenerative disorder of the spine, whereby pain is a prominent feature that poses therapeutic challenges even after surgical intervention. There are no randomized, placebo-controlled studies utilizing repetitive spinal magnetic stimulation (SMS) in pain associated with lumbar spondylosis. In this study, we utilize SMS technique for patients with this condition in a pilot clinical trial. We randomized 20 patients into SMS treatment or placebo arms. All patients must have clinical and radiological evidence of lumbar spondylosis. Patients should present with pain in the lumbar region, localized or radiating down the lower limbs in a radicular distribution. SMS was delivered with a Medtronic R30 repetitive magnetic stimulator (Medtronic Corporation, Skovlunde, Denmark) connected to a C-B60 figure of eight coil capable of delivering a maximum output of 2 Tesla per pulse. The coil measured 90 mm in each wing and was centered over the surface landmark corresponding to the cauda equina region. The coil was placed flat over the back with the handle pointing cranially. Each patient on active treatment received 200 trains of five pulses delivered at 10 Hz, at an interval of 5 seconds between each train. "Sham" SMS was delivered with the coil angled vertically and one of the wing edges in contact with the stimulation point. All patients tolerated the procedure well and no side effects of SMS were reported. In the treatment arm, SMS had resulted in significant pain reduction immediately and at Day 4 after treatment (P < 0.05). In the placebo arm, however, no significant pain reduction was seen immediately and at Day 4 after SMS. SMS in the treatment arm had resulted in mean pain reduction of 62.3% postprocedure and 17.4% at Day 4. The placebo arm only achieved pain reduction of 6.1% postprocedure and 4.5% at Day 4. This is the first study to show that a single session of SMS resulted in significant improvement of pain associated with lumbar spondylosis in a randomized, double-blind, placebo-controlled setting. The novel findings support the potential of this technique for future studies pertaining to neuropathic pain. Wiley Periodicals, Inc.

  4. Cost-Utility of "Doxorubicin and Cyclophosphamide" versus "Gemcitabine and Paclitaxel" for Treatment of Patients with Breast Cancer in Iran.

    PubMed

    Hatam, Nahid; Askarian, Mehrdad; Javan-Noghabi, Javad; Ahmadloo, Niloofar; Mohammadianpanah, Mohammad

    2015-01-01

    A cost-utility analysis was performed to assess the cost-utility of neoadjuvant chemotherapy regimens containing doxorubicin and cyclophosphamide (AC) versus paclitaxel and gemcitabine (PG) for locally advanced breast cancer patients in Iran. This cross-sectional study in Namazi hospital in Shiraz, in the south of Iran covered 64 breast cancer patients. According to the random numbers, the patients were divided into two groups, 32 receiving AC and 32 PG. Costs were identified and measured from a community perspective. These items included medical and non-medical direct and indirect costs. In this study, a data collection form was used. To assess the utility of the two regimens, the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire-Core30 (EORTC QLQ-C30) was applied. Using a decision tree, we calculated the expected costs and quality adjusted life years (QALYs) for both methods; also, the incremental cost-effectiveness ratio was assessed. The results of the decision tree showed that in the AC arm, the expected cost was 39,170 US$ and the expected QALY was 3.39 and in the PG arm, the expected cost was 43,336 dollars and the expected QALY was 2.64. Sensitivity analysis showed the cost effectiveness of the AC and ICER=-5535 US$. Overall, the results showed that AC to be superior to PG in treatment of patients with breast cancer, being less costly and more effective.

  5. Tetra-primer ARMS-PCR identified four pivotal genetic variations in bovine PNPLA3 gene and its expression patterns.

    PubMed

    Wang, Zi-nian; Cai, Han-fang; Li, Ming-xun; Cao, Xiu-kai; Lan, Xian-yong; Lei, Chu-zhao; Chen, Hong

    2016-01-10

    Patatin-like phospholipase domain-containing protein 3 (PNPLA3), a member of the patatin like phospholipase domain-containing (PNPLA) family, plays an important role in energy balance, fat metabolism regulation, glucose metabolism and fatty liver disease. Tetra-primer amplification refractory mutation system PCR (T-ARMS-PCR) is a new method offering fast detection and extreme simplicity at a negligible cost for SNP genotyping. In this paper, we investigated the genetic variations at different ages of 660 Chinese indigenous cattle belonging to three breeds (QC, NY, JX) and applied T-ARMS-PCR and PCR-RFLP methods to genotype four SNPs, SNP1: g.A2980G, SNP2: g.A2996T, SNP3: g.A36718G, SNP4: g.G36850A. The statistical analyses indicated that these 4 SNPs affected growth traits markedly (P<0.05) in QC population, whereas combined haplotypes were not (P>0.05). The qPCR (quantitative PCR) indicated that bovine PNPLA3 gene was exclusively expressed in fat tissues. Besides, the analysis between SNP and mRNA expression revealed that, in SNP1, the expression of AG was much higher than AA and GG (P<0.05), which was in accordance with the results of growth traits association analysis, while the results of SNP4 was not. These results supported high potential that SNPs of bovine PNPLA3 gene might be utilized as genetic markers in marker-assisted selection (MAS) for Chinese cattle breeding programs. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. The Potential Uses of Commercial Satellite Imagery in the Middle East

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vannoni, M.G.

    1999-06-08

    It became clear during the workshop that the applicability of commercial satellite imagery to the verification of future regional arms control agreements is limited at this time. Non-traditional security topics such as environmental protection, natural resource management, and the development of infrastructure offer the more promising applications for commercial satellite imagery in the short-term. Many problems and opportunities in these topics are regional, or at least multilateral, in nature. A further advantage is that, unlike arms control and nonproliferation applications, cooperative use of imagery in these topics can be done independently of the formal Middle East Peace Process. The valuemore » of commercial satellite imagery to regional arms control and nonproliferation, however, will increase during the next three years as new, more capable satellite systems are launched. Aerial imagery, such as that used in the Open Skies Treaty, can also make significant contributions to both traditional and non-traditional security applications but has the disadvantage of requiring access to national airspace and potentially higher cost. There was general consensus that commercial satellite imagery is under-utilized in the Middle East and resources for remote sensing, both human and institutional, are limited. This relative scarcity, however, provides a natural motivation for collaboration in non-traditional security topics. Collaborations between scientists, businesses, universities, and non-governmental organizations can work at the grass-roots level and yield contributions to confidence building as well as scientific and economic results. Joint analysis projects would benefit the region as well as establish precedents for cooperation.« less

  7. The effects of the arm swing on biomechanical and physiological aspects of roller ski skating.

    PubMed

    Hegge, Ann Magdalen; Ettema, Gertjan; de Koning, Jos J; Rognstad, Asgeir Bakken; Hoset, Martin; Sandbakk, Øyvind

    2014-08-01

    This study analyzed the biomechanical and physiological effects of the arm swing in roller ski skating, and compared leg-skating (i.e. ski skating without poles) using a pronounced arm swing (SWING) with leg-skating using locked arms (LOCKED). Sixteen elite male cross-country skiers performed submaximal stages at 10, 15 and 20kmh(-1) on a 2% inclined treadmill in the two techniques. SWING demonstrated higher peak push-off forces and a higher force impulse at all speeds, but a longer cycle length only at the highest speed (all P<.05), indicating a lower force effectiveness with SWING at the two lowest speeds. Additionally, the flexion-extension movement in the lower limbs was more pronounced for SWING. Oxygen uptake was higher for SWING at the two lowest speeds (both P<.05) without any differences in blood lactate. At the highest speed, oxygen uptake did not differ between SWING and LOCKED, but the RER, blood lactate and ventilation were lower with SWING (all P<.05). Taken together, these results demonstrate that utilizing the arm swing in roller ski skating increases the ski forces and aerobic energy cost at low and moderate speeds, whereas the greater forces at high speed lead to a longer cycle length and smaller anaerobic contribution. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. A cost-effective intelligent robotic system with dual-arm dexterous coordination and real-time vision

    NASA Technical Reports Server (NTRS)

    Marzwell, Neville I.; Chen, Alexander Y. K.

    1991-01-01

    Dexterous coordination of manipulators based on the use of redundant degrees of freedom, multiple sensors, and built-in robot intelligence represents a critical breakthrough in development of advanced manufacturing technology. A cost-effective approach for achieving this new generation of robotics has been made possible by the unprecedented growth of the latest microcomputer and network systems. The resulting flexible automation offers the opportunity to improve the product quality, increase the reliability of the manufacturing process, and augment the production procedures for optimizing the utilization of the robotic system. Moreover, the Advanced Robotic System (ARS) is modular in design and can be upgraded by closely following technological advancements as they occur in various fields. This approach to manufacturing automation enhances the financial justification and ensures the long-term profitability and most efficient implementation of robotic technology. The new system also addresses a broad spectrum of manufacturing demand and has the potential to address both complex jobs as well as highly labor-intensive tasks. The ARS prototype employs the decomposed optimization technique in spatial planning. This technique is implemented to the framework of the sensor-actuator network to establish the general-purpose geometric reasoning system. The development computer system is a multiple microcomputer network system, which provides the architecture for executing the modular network computing algorithms. The knowledge-based approach used in both the robot vision subsystem and the manipulation control subsystems results in the real-time image processing vision-based capability. The vision-based task environment analysis capability and the responsive motion capability are under the command of the local intelligence centers. An array of ultrasonic, proximity, and optoelectronic sensors is used for path planning. The ARS currently has 18 degrees of freedom made up by two articulated arms, one movable robot head, and two charged coupled device (CCD) cameras for producing the stereoscopic views, and articulated cylindrical-type lower body, and an optional mobile base. A functional prototype is demonstrated.

  9. An ARM data-oriented diagnostics package to evaluate the climate model simulation

    NASA Astrophysics Data System (ADS)

    Zhang, C.; Xie, S.

    2016-12-01

    A set of diagnostics that utilize long-term high frequency measurements from the DOE Atmospheric Radiation Measurement (ARM) program is developed for evaluating the regional simulation of clouds, radiation and precipitation in climate models. The diagnostics results are computed and visualized automatically in a python-based package that aims to serve as an easy entry point for evaluating climate simulations using the ARM data, as well as the CMIP5 multi-model simulations. Basic performance metrics are computed to measure the accuracy of mean state and variability of simulated regional climate. The evaluated physical quantities include vertical profiles of clouds, temperature, relative humidity, cloud liquid water path, total column water vapor, precipitation, sensible and latent heat fluxes, radiative fluxes, aerosol and cloud microphysical properties. Process-oriented diagnostics focusing on individual cloud and precipitation-related phenomena are developed for the evaluation and development of specific model physical parameterizations. Application of the ARM diagnostics package will be presented in the AGU session. This work is performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344, IM release number is: LLNL-ABS-698645.

  10. Intermanual transfer in training with an upper-limb myoelectric prosthesis simulator: a mechanistic, randomized, pretest-posttest study.

    PubMed

    Romkema, Sietske; Bongers, Raoul M; van der Sluis, Corry K

    2013-01-01

    Intermanual transfer may improve prosthetic handling and acceptance if used in training soon after an amputation. The purpose of this study was to determine whether intermanual transfer effects can be detected after training with a myoelectric upper-limb prosthesis simulator. A mechanistic, randomized, pretest-posttest design was used. A total of 48 right-handed participants (25 women, 23 men) who were able-bodied were randomly assigned to an experimental group or a control group. The experimental group performed a training program of 5 days' duration using the prosthesis simulator. To determine the improvement in skill, a test was administered before, immediately after, and 6 days after training. The control group only performed the tests. Training was performed with the unaffected arm, and tests were performed with the affected arm (the affected arm simulating an amputated limb). Half of the participants were tested with the dominant arm and half with the nondominant arm. Initiation time was defined as the time from starting signal until start of the movement, movement time was defined as the time from the beginning of the movement until completion of the task, and force control was defined as the maximal applied force on a deformable object. The movement time decreased significantly more in the experimental group (F₂,₉₂=7.42, P=.001, η²(G)=.028) when compared with the control group. This finding is indicative of faster handling of the prosthesis. No statistically significant differences were found between groups with regard to initiation time and force control. We did not find a difference in intermanual transfer between the dominant and nondominant arms. The training utilized participants who were able-bodied in a laboratory setting and focused only on transradial amputations. Intermanual transfer was present in the affected arm after training the unaffected arm with a myoelectric prosthesis simulator, and this effect did not depend on laterality. This effect may improve rehabilitation of patients with an upper-limb amputation.

  11. Automatic cable artifact removal for cardiac C-arm CT imaging

    NASA Astrophysics Data System (ADS)

    Haase, C.; Schäfer, D.; Kim, M.; Chen, S. J.; Carroll, J.; Eshuis, P.; Dössel, O.; Grass, M.

    2014-03-01

    Cardiac C-arm computed tomography (CT) imaging using interventional C-arm systems can be applied in various areas of interventional cardiology ranging from structural heart disease and electrophysiology interventions to valve procedures in hybrid operating rooms. In contrast to conventional CT systems, the reconstruction field of view (FOV) of C-arm systems is limited to a region of interest in cone-beam (along the patient axis) and fan-beam (in the transaxial plane) direction. Hence, highly X-ray opaque objects (e.g. cables from the interventional setup) outside the reconstruction field of view, yield streak artifacts in the reconstruction volume. To decrease the impact of these streaks a cable tracking approach on the 2D projection sequences with subsequent interpolation is applied. The proposed approach uses the fact that the projected position of objects outside the reconstruction volume depends strongly on the projection perspective. By tracking candidate points over multiple projections only objects outside the reconstruction volume are segmented in the projections. The method is quantitatively evaluated based on 30 simulated CT data sets. The 3D root mean square deviation to a reference image could be reduced for all cases by an average of 50 % (min 16 %, max 76 %). Image quality improvement is shown for clinical whole heart data sets acquired on an interventional C-arm system.

  12. Value of syndromic surveillance within the Armed Forces for early warning during a dengue fever outbreak in French Guiana in 2006

    PubMed Central

    Meynard, Jean-Baptiste; Chaudet, Hervé; Texier, Gaetan; Ardillon, Vanessa; Ravachol, Françoise; Deparis, Xavier; Jefferson, Henry; Dussart, Philippe; Morvan, Jacques; Boutin, Jean-Paul

    2008-01-01

    Background A dengue fever outbreak occured in French Guiana in 2006. The objectives were to study the value of a syndromic surveillance system set up within the armed forces, compared to the traditional clinical surveillance system during this outbreak, to highlight issues involved in comparing military and civilian surveillance systems and to discuss the interest of syndromic surveillance for public health response. Methods Military syndromic surveillance allows the surveillance of suspected dengue fever cases among the 3,000 armed forces personnel. Within the same population, clinical surveillance uses several definition criteria for dengue fever cases, depending on the epidemiological situation. Civilian laboratory surveillance allows the surveillance of biologically confirmed cases, within the 200,000 inhabitants. Results It was shown that syndromic surveillance detected the dengue fever outbreak several weeks before clinical surveillance, allowing quick and effective enhancement of vector control within the armed forces. Syndromic surveillance was also found to have detected the outbreak before civilian laboratory surveillance. Conclusion Military syndromic surveillance allowed an early warning for this outbreak to be issued, enabling a quicker public health response by the armed forces. Civilian surveillance system has since introduced syndromic surveillance as part of its surveillance strategy. This should enable quicker public health responses in the future. PMID:18597694

  13. Anti-backlash drive systems for multi-degree freedom devices

    DOEpatents

    Tsai, Lung-Wen; Chang, Sun-Lai

    1993-01-01

    A new and innovative concept for the control of backlash in gear-coupled transmission mechanisms. The concept utilizes redundant unidirectional drives to assure positive coupling of gear meshes at all times. Based on this concept, a methodology for the enumeration of admissible redundant-drive backlash-free robotic mechanisms has been established. Some typical two- and three-DOF mechanisms are disclosed. Furthermore, actuator torques have been derived as functions of either joint torques or end-effector dynamic performance requirements. A redundantly driven gear coupled transmission mechanism manipulator has a fail-safe advantage in that, except of the loss of backlash control, it can continue to function when one of its actuators fails. A two-DOF backlash-free arm has been reduced to practice to demonstrate the principle.

  14. TU-FG-BRB-11: Design and Evaluation of a Robotic C-Arm CBCT System for Image-Guided Proton Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hua, C; Yao, W; Farr, J

    Purpose: To describe the design and performance of a ceiling-mounted robotic C-arm CBCT system for image-guided proton therapy. Methods: Uniquely different from traditional C-arm CBCT used in interventional radiology, the imaging system was designed to provide volumetric image guidance for patients treated on a 190-degree proton gantry system and a 6 degree-of-freedom (DOF) robotic patient positioner. The mounting of robotic arms to the ceiling rails, rather than gantry or nozzle, provides the flexibility in imaging locations (isocenter, iso+27cm in X, iso+100cm in Y) in the room and easier upgrade as technology advances. A kV X-ray tube and a 43×43cm flatmore » panel imager were mounted to a rotating C-ring (87cm diameter), which is coupled to the C-arm concentrically. Both C-arm and the robotic arm remain stationary during imaging to maintain high position accuracy. Source-to-axis distance and source-to-imager distance are 100 and 150cm, respectively. A 14:1 focused anti-scatter grid and a bowtie filer are used for image acquisition. A unique automatic collimator device of 4 independent blades for adjusting field of view and reducing patient dose has also been developed. Results: Sub-millimeter position accuracy and repeatability of the robotic C-arm were measured with a laser tracker. High quality CBCT images for positioning can be acquired with a weighted CTDI of 3.6mGy (head in 200° full fan mode: 100kV, 20mA, 20ms, 10fps)-8.7 mGy (pelvis in 360° half fan mode: 125kV, 42mA, 20ms, 10fps). Image guidance accuracy achieved <1mm (3D vector) with automatic 3D-3D registration for anthropomorphic head and pelvis phantoms. Since November 2015, 22 proton therapy patients have undergone daily CBCT imaging for 6 DOF positioning. Conclusion: Decoupled from gantry and nozzle, this CBCT system provides a unique solution for volumetric image guidance with half/partial proton gantry systems. We demonstrated that daily CBCT can be integrated into proton therapy for pre-treatment position verification.« less

  15. Rotational manipulation of single cells and organisms using acoustic waves

    PubMed Central

    Ahmed, Daniel; Ozcelik, Adem; Bojanala, Nagagireesh; Nama, Nitesh; Upadhyay, Awani; Chen, Yuchao; Hanna-Rose, Wendy; Huang, Tony Jun

    2016-01-01

    The precise rotational manipulation of single cells or organisms is invaluable to many applications in biology, chemistry, physics and medicine. In this article, we describe an acoustic-based, on-chip manipulation method that can rotate single microparticles, cells and organisms. To achieve this, we trapped microbubbles within predefined sidewall microcavities inside a microchannel. In an acoustic field, trapped microbubbles were driven into oscillatory motion generating steady microvortices which were utilized to precisely rotate colloids, cells and entire organisms (that is, C. elegans). We have tested the capabilities of our method by analysing reproductive system pathologies and nervous system morphology in C. elegans. Using our device, we revealed the underlying abnormal cell fusion causing defective vulval morphology in mutant worms. Our acoustofluidic rotational manipulation (ARM) technique is an easy-to-use, compact, and biocompatible method, permitting rotation regardless of optical, magnetic or electrical properties of the sample under investigation. PMID:27004764

  16. Rotational manipulation of single cells and organisms using acoustic waves.

    PubMed

    Ahmed, Daniel; Ozcelik, Adem; Bojanala, Nagagireesh; Nama, Nitesh; Upadhyay, Awani; Chen, Yuchao; Hanna-Rose, Wendy; Huang, Tony Jun

    2016-03-23

    The precise rotational manipulation of single cells or organisms is invaluable to many applications in biology, chemistry, physics and medicine. In this article, we describe an acoustic-based, on-chip manipulation method that can rotate single microparticles, cells and organisms. To achieve this, we trapped microbubbles within predefined sidewall microcavities inside a microchannel. In an acoustic field, trapped microbubbles were driven into oscillatory motion generating steady microvortices which were utilized to precisely rotate colloids, cells and entire organisms (that is, C. elegans). We have tested the capabilities of our method by analysing reproductive system pathologies and nervous system morphology in C. elegans. Using our device, we revealed the underlying abnormal cell fusion causing defective vulval morphology in mutant worms. Our acoustofluidic rotational manipulation (ARM) technique is an easy-to-use, compact, and biocompatible method, permitting rotation regardless of optical, magnetic or electrical properties of the sample under investigation.

  17. KSC-02pd0769

    NASA Image and Video Library

    2002-05-27

    KENNEDY SPACE CENTER, FLA. - At the KSC Shuttle Landing Facility, STS-111 Mission Specialist Philippe Perrin, with the French Space Agency, waits for the rest of the crew before departing for Crew Quarters. The crew has arrived to prepare for launch. Mission STS-111, known as Utilization Flight 2, is carrying supplies and equipment to the International Space Station. The payload includes the Multi-Purpose Logistics Module Leonardo, the Mobile Base System, which will be installed on the Mobile Transporter to complete the Canadian Mobile Servicing System, or MSS, and a replacement wrist/roll joint for Canadarm 2. The mechanical arm will then have the capability to "inchworm" from the U.S. Lab Destiny to the MSS and travel along the truss to work sites. Also on board will be Expedition 5, traveling to the Station on Space Shuttle Endeavour as the replacement crew for Expedition 4, who will return to Earth aboard the orbiter. Launch is scheduled for May 30, 2002

  18. KSC-02pd0767

    NASA Image and Video Library

    2002-05-27

    KENNEDY SPACE CENTER, FLA. - STS-111 Mission Specialist Philippe Perrin, with the French Space Agency, smiles on his arrival at KSC aboard a T-38 jet aircraft to prepare for launch. Mission STS-111, known as Utilization Flight 2, is carrying supplies and equipment to the International Space Station. The payload includes the Multi-Purpose Logistics Module Leonardo, the Mobile Base System, which will be installed on the Mobile Transporter to complete the Canadian Mobile Servicing System, or MSS, and a replacement wrist/roll joint for Canadarm 2. The mechanical arm will then have the capability to "inchworm" from the U.S. Lab Destiny to the MSS and travel along the truss to work sites. Also on board will be Expedition 5, traveling to the Station on Space Shuttle Endeavour as the replacement crew for Expedition 4, who will return to Earth aboard the orbiter. Launch is scheduled for May 30, 2002

  19. Accuracy of screw fixation using the O-arm® and StealthStation® navigation system for unstable pelvic ring fractures.

    PubMed

    Takeba, Jun; Umakoshi, Kensuke; Kikuchi, Satoshi; Matsumoto, Hironori; Annen, Suguru; Moriyama, Naoki; Nakabayashi, Yuki; Sato, Norio; Aibiki, Mayuki

    2018-04-01

    Screw fixation for unstable pelvic ring fractures is generally performed using the C-arm. However, some studies reported erroneous piercing with screws, nerve injuries, and vessel injuries. Recent studies have reported the efficacy of screw fixations using navigation systems. The purpose of this retrospective study was to investigate the accuracy of screw fixation using the O-arm ® imaging system and StealthStation ® navigation system for unstable pelvic ring fractures. The participants were 10 patients with unstable pelvic ring fractures, who underwent screw fixations using the O-arm StealthStation navigation system (nine cases with iliosacral screw and one case with lateral compression screw). We investigated operation duration, bleeding during operation, the presence of complications during operation, and the presence of cortical bone perforation by the screws based on postoperative CT scan images. We also measured the difference in screw tip positions between intraoperative navigation screen shot images and postoperative CT scan images. The average operation duration was 71 min, average bleeding was 12 ml, and there were no nerve or vessel injuries during the operation. There was no cortical bone perforation by the screws. The average difference between intraoperative navigation images and postoperative CT images was 2.5 ± 0.9 mm, for all 18 screws used in this study. Our results suggest that the O-arm StealthStation navigation system provides accurate screw fixation for unstable pelvic ring fractures.

  20. KSC-07pd2866

    NASA Image and Video Library

    2007-10-01

    KENNEDY SPACE CENTER, FLA. -- In the Space Station Processing Facility at NASA's Kennedy Space Center, the starboard arm of the Special Purpose Dexterous Manipulator, known as Dextre, is moved across the facility. The arm will be installed on the base. Dextre is a sophisticated dual-armed robot, which is part of Canada's contribution to the International Space Station (ISS). Along with Canadarm2, whose technical name is the Space Station Remote Manipulator System, and a moveable work platform called the Mobile Base System, these three elements form a robotic system called the Mobile Servicing System, or MSS. The three components have been designed to work together or independently. Dextre is part of the payload scheduled on mission STS-123, targeted to launch Feb. 14. Photo credit: NASA/George Shelton

  1. Translational control of a graphically simulated robot arm by kinematic rate equations that overcome elbow joint singularity

    NASA Technical Reports Server (NTRS)

    Barker, L. K.; Houck, J. A.; Carzoo, S. W.

    1984-01-01

    An operator commands a robot hand to move in a certain direction relative to its own axis system by specifying a velocity in that direction. This velocity command is then resolved into individual joint rotational velocities in the robot arm to effect the motion. However, the usual resolved-rate equations become singular when the robot arm is straightened. To overcome this elbow joint singularity, equations were developed which allow continued translational control of the robot hand even though the robot arm is (or is nearly) fully extended. A feature of the equations near full arm extension is that an operator simply extends and retracts the robot arm to reverse the direction of the elbow bend (difficult maneuver for the usual resolved-rate equations). Results show successful movement of a graphically simulated robot arm.

  2. New prototype of acousto-optical radio-wave spectrometer with parallel frequency processing for astrophysical applications

    NASA Astrophysics Data System (ADS)

    Shcherbakov, Alexandre S.; Chavez Dagostino, Miguel; Arellanes, Adan O.; Aguirre Lopez, Arturo

    2016-09-01

    We develop a multi-band spectrometer with a few spatially parallel optical arms for the combined processing of their data flow. Such multi-band capability has various applications in astrophysical scenarios at different scales: from objects in the distant universe to planetary atmospheres in the Solar system. Each optical arm exhibits original performances to provide parallel multi-band observations with different scales simultaneously. Similar possibility is based on designing each optical arm individually via exploiting different materials for acousto-optical cells operating within various regimes, frequency ranges and light wavelengths from independent light sources. Individual beam shapers provide both the needed incident light polarization and the required apodization to increase the dynamic range of a system. After parallel acousto-optical processing, data flows are united by the joint CCD matrix on the stage of the combined electronic data processing. At the moment, the prototype combines still three bands, i.e. includes three spatial optical arms. The first low-frequency arm operates at the central frequencies 60-80 MHz with frequency bandwidth 40 MHz. The second arm is oriented to middle-frequencies 350-500 MHz with frequency bandwidth 200-300 MHz. The third arm is intended for ultra-high-frequency radio-wave signals about 1.0-1.5 GHz with frequency bandwidth <300 MHz. To-day, this spectrometer has the following preliminary performances. The first arm exhibits frequency resolution 20 KHz; while the second and third arms give the resolution 150-200 KHz. The numbers of resolvable spots are 1500- 2000 depending on the regime of operation. The fourth optical arm at the frequency range 3.5 GHz is currently under construction.

  3. Earth Observations taken by Expedition 26 Crew

    NASA Image and Video Library

    2010-12-21

    ISS026-E-011834 (21 Dec. 2010) --- This photo, recorded by an Expedition 26 crewmember on the International Space Station, features two components of the Mobile Servicing System on the orbital outpost. Part of the Station Remote Manipulator System?s arm (Canadarm2) is visible at left. Dextre (right), also known as the Special Purpose Dexterous Manipulator (SPDM), is a two armed robot.

  4. Conventional and right-sided screening for subcutaneous ICD in a population with congenital heart disease at high risk of sudden cardiac death.

    PubMed

    Alonso, Pau; Osca, Joaquín; Rueda, Joaquín; Cano, Oscar; Pimenta, Pedro; Andres, Ana; Sancho, María José; Martinez, Luis

    2017-11-01

    Information regarding suitability for subcutaneous defibrillator (sICD) implantation in tetralogy of Fallot (ToF) and systemic right ventricle is scarce and needs to be further explored. The main objective of our study was to determine the proportion of patients with ToF and systemic right ventricle eligible for sICD with both, standard and right-sided screening methods. Secondary objectives were: (i) to study sICD eligibility specifically in patients at high risk of sudden cardiac death, (ii) to identify independent predictors for sICD eligibility, and (iii) to compare the proportion of eligible patients in a nonselected ICD population. We recruited 102 patients with ToF, 33 with systemic right ventricle, and 40 consecutive nonselected patients. Conventional electrocardiographic screening was performed as usual. Right-sided alternative screening was studied by positioning the left-arm and right-arm electrodes 1 cm right lateral of the xiphoid midline. The Boston Scientific ECG screening tool was utilized. In high-risk patients with ToF, eligibility was higher with right-sided screening in comparison with standard screening (61% vs. 44%; p = .018). Eligibility in high-risk right ventricle population was identical with both screening methods (77%, p = ns). The only independent predictor for sICD eligibility was QRS duration. In high-risk patients with ToF, right-sided implantation of the sICD could be an alternative to a conventional ICD. In patients with a systemic right ventricle, implantation of a sICD is an alternative to a conventional sICD. © 2017 Wiley Periodicals, Inc.

  5. TRIMETHYLTIN, A SELECTIVE LIMBIC SYSTEM NEUROTOXICANT, IMPAIRS RADIAL-ARM MAZE PERFORMANCE

    EPA Science Inventory

    Rats were trained for fifteen sessions in an automated eight arm radial maze prior to treatment with 6 mg/kg trimethyltin chloride. This compound is a neurotoxicant which primarily damages the limbic system, in particular pyramidal cells in the CA3 region of the hippocampus. Foll...

  6. An open and configurable embedded system for EMG pattern recognition implementation for artificial arms.

    PubMed

    Jun Liu; Fan Zhang; Huang, He Helen

    2014-01-01

    Pattern recognition (PR) based on electromyographic (EMG) signals has been developed for multifunctional artificial arms for decades. However, assessment of EMG PR control for daily prosthesis use is still limited. One of the major barriers is the lack of a portable and configurable embedded system to implement the EMG PR control. This paper aimed to design an open and configurable embedded system for EMG PR implementation so that researchers can easily modify and optimize the control algorithms upon our designed platform and test the EMG PR control outside of the lab environments. The open platform was built on an open source embedded Linux Operating System running a high-performance Gumstix board. Both the hardware and software system framework were openly designed. The system was highly flexible in terms of number of inputs/outputs and calibration interfaces used. Such flexibility enabled easy integration of our embedded system with different types of commercialized or prototypic artificial arms. Thus far, our system was portable for take-home use. Additionally, compared with previously reported embedded systems for EMG PR implementation, our system demonstrated improved processing efficiency and high system precision. Our long-term goals are (1) to develop a wearable and practical EMG PR-based control for multifunctional artificial arms, and (2) to quantify the benefits of EMG PR-based control over conventional myoelectric prosthesis control in a home setting.

  7. Impact of continuous glucose monitoring on quality of life, treatment satisfaction, and use of medical care resources: analyses from the SWITCH study.

    PubMed

    Hommel, E; Olsen, B; Battelino, T; Conget, I; Schütz-Fuhrmann, I; Hoogma, R; Schierloh, U; Sulli, N; Gough, H; Castañeda, J; de Portu, S; Bolinder, J

    2014-10-01

    To investigate the impact of continuous glucose monitoring (CGM) on health-related quality of life (HRQOL), treatment satisfaction (TS) medical resource use, and indirect costs in the SWITCH study. SWITCH was a multicentre, randomized, crossover study. Patients with type 1 diabetes (n = 153) using continuous subcutaneous insulin infusion (CSII) were randomized to a 12 month sensor-On/Off or sensor-Off/On sequence (6 months each treatment), with a 4-month washout between periods. HRQOL in children and TS in adults were measured using validated questionnaires. Medical resource utilization data were collected. In adults, TS was significantly higher in the sensor-On arm, and there were significant improvements in ratings for treatment convenience and flexibility. There were no clinically significant differences in children's HRQOL or parents' proxy ratings. The incidence of severe hypoglycaemia, unscheduled visits, or diabetes-related hospitalizations did not differ significantly between the two arms. Adult patients made fewer telephone consultations during the sensor-On arm; children's caregivers made similar numbers of telephone consultations during both arms, and calls were on average only 3 min longer during the sensor-On arm. Regarding indirect costs, children with >70 % sensor usage missed fewer school days, compared with the sensor-Off arm (P = 0.0046) but there was no significant difference in the adults days of work off. The addition of CGM to CSII resulted in better metabolic control without imposing an additional burden on the patient or increased medical resource use, and offered the potential for cost offsets.

  8. Evaluation of a dynamic arm support for seated and standing tasks: a laboratory study of electromyography and subjective feedback.

    PubMed

    Odell, Dan; Barr, Alan; Goldberg, Robert; Chung, Jeffrey; Rempel, David

    2007-04-01

    The goal of this study was to determine whether a new dynamic arm support system reduced shoulder and arm muscle load for seated and standing hand/ arm tasks. The new system provides support for both horizontal and vertical arm motion. A total of 11 participants performed ten tasks (five seated and five standing) both with and without the arm support. Outcomes were assessed with electromyography and subjective feedback. Muscle activity was measured over the dominant side supraspinatus, triceps and forearm extensor muscles. Significant (p < 0.01) reductions in static muscle activity were observed in one of ten tasks performed with the support device for the supraspinatus muscle, in five tasks for the triceps and in one task for forearm extensor muscles. Likewise, a significant improvement in subjective measures was reported with the support device for 'ease of task' for two of ten tasks, for 'forearm comfort' for three of ten tasks and for 'shoulder effort' for six of ten tasks. The results suggest that a dynamic forearm support may improve subjective comfort and reduce static muscle loads in the upper extremity for tasks that involve horizontal movement of the arms. For rapid motions, the value of the support is limited due to internal inertia and friction.

  9. An Analysis of Air Force Service Contract Cases Appealed to the Armed Services Board of Contract Appeals

    DTIC Science & Technology

    1988-09-01

    DEM/88S- 1 AN ANALYSIS OF AIR FORCE SERVICE CONTRACT CASES APPEALED TO THE ARMED SERVICES BOARD OF CONTRACT APPEALS THESIS Diane L. Bowden First...CONTRACT CASES APPEALED TO THE ARMED SERVICES BOARD OF CONTRACT APPEALS THESIS Presented to the Faculty of the School of Systems and Logistics of the Air...analyze, and condense information that might be useful to contracting and contract management personnel. Armed Services Board of Contract Appeals

  10. Kinematic synthesis of adjustable robotic mechanisms

    NASA Astrophysics Data System (ADS)

    Chuenchom, Thatchai

    1993-01-01

    Conventional hard automation, such as a linkage-based or a cam-driven system, provides high speed capability and repeatability but not the flexibility required in many industrial applications. The conventional mechanisms, that are typically single-degree-of-freedom systems, are being increasingly replaced by multi-degree-of-freedom multi-actuators driven by logic controllers. Although this new trend in sophistication provides greatly enhanced flexibility, there are many instances where the flexibility needs are exaggerated and the associated complexity is unnecessary. Traditional mechanism-based hard automation, on the other hand, neither can fulfill multi-task requirements nor are cost-effective mainly due to lack of methods and tools to design-in flexibility. This dissertation attempts to bridge this technological gap by developing Adjustable Robotic Mechanisms (ARM's) or 'programmable mechanisms' as a middle ground between high speed hard automation and expensive serial jointed-arm robots. This research introduces the concept of adjustable robotic mechanisms towards cost-effective manufacturing automation. A generalized analytical synthesis technique has been developed to support the computational design of ARM's that lays the theoretical foundation for synthesis of adjustable mechanisms. The synthesis method developed in this dissertation, called generalized adjustable dyad and triad synthesis, advances the well-known Burmester theory in kinematics to a new level. While this method provides planar solutions, a novel patented scheme is utilized for converting prescribed three-dimensional motion specifications into sets of planar projections. This provides an analytical and a computational tool for designing adjustable mechanisms that satisfy multiple sets of three-dimensional motion specifications. Several design issues were addressed, including adjustable parameter identification, branching defect, and mechanical errors. An efficient mathematical scheme for identification of adjustable member was also developed. The analytical synthesis techniques developed in this dissertation were successfully implemented in a graphic-intensive user-friendly computer program. A physical prototype of a general purpose adjustable robotic mechanism has been constructed to serve as a proof-of-concept model.

  11. A system-level mathematical model of Basal Ganglia motor-circuit for kinematic planning of arm movements.

    PubMed

    Salimi-Badr, Armin; Ebadzadeh, Mohammad Mehdi; Darlot, Christian

    2018-01-01

    In this paper, a novel system-level mathematical model of the Basal Ganglia (BG) for kinematic planning, is proposed. An arm composed of several segments presents a geometric redundancy. Thus, selecting one trajectory among an infinite number of possible ones requires overcoming redundancy, according to some kinds of optimization. Solving this optimization is assumed to be the function of BG in planning. In the proposed model, first, a mathematical solution of kinematic planning is proposed for movements of a redundant arm in a plane, based on minimizing energy consumption. Next, the function of each part in the model is interpreted as a possible role of a nucleus of BG. Since the kinematic variables are considered as vectors, the proposed model is presented based on the vector calculus. This vector model predicts different neuronal populations in BG which is in accordance with some recent experimental studies. According to the proposed model, the function of the direct pathway is to calculate the necessary rotation of each joint, and the function of the indirect pathway is to control each joint rotation considering the movement of the other joints. In the proposed model, the local feedback loop between Subthalamic Nucleus and Globus Pallidus externus is interpreted as a local memory to store the previous amounts of movements of the other joints, which are utilized by the indirect pathway. In this model, activities of dopaminergic neurons would encode, at short-term, the error between the desired and actual positions of the end-effector. The short-term modulating effect of dopamine on Striatum is also modeled as cross product. The model is simulated to generate the commands of a redundant manipulator. The performance of the model is studied for different reaching movements between 8 points in a plane. Finally, some symptoms of Parkinson's disease such as bradykinesia and akinesia are simulated by modifying the model parameters, inspired by the dopamine depletion. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Network of movement and proximity sensors for monitoring upper-extremity motor activity after stroke: proof of principle.

    PubMed

    Sokal, Brad; Uswatte, Gitendra; Barman, Joydip; Brewer, Michael; Byrom, Ezekiel; Latten, Jessica; Joseph, Jeethu; Serafim, Camila; Ghaffari, Touraj; Sarkar, Nilanjan

    2014-03-01

    To test the convergent validity of an objective method, Sensor-Enabled Radio-frequency Identification System for Monitoring Arm Activity (SERSMAA), that distinguishes between functional and nonfunctional activity. Cross-sectional study. Laboratory. Participants (N=25) were ≥0.2 years poststroke (median, 9) with a wide range of severity of upper-extremity hemiparesis. Not applicable. After stroke, laboratory tests of the motor capacity of the more-affected arm poorly predict spontaneous use of that arm in daily life. However, available subjective methods for measuring everyday arm use are vulnerable to self-report biases, whereas available objective methods only provide information on the amount of activity without regard to its relation with function. The SERSMAA consists of a proximity-sensor receiver on the more-affected arm and multiple units placed on objects. Functional activity is signaled when the more-affected arm is close to an object that is moved. Participants were videotaped during a laboratory simulation of an everyday activity, that is, setting a table with cups, bowls, and plates instrumented with transmitters. Observers independently coded the videos in 2-second blocks with a validated system for classifying more-affected arm activity. There was a strong correlation (r=.87, P<.001) between time that the more-affected arm was used for handling objects according to the SERSMAA and functional activity according to the observers. The convergent validity of SERSMAA for measuring more-affected arm functional activity after stroke was supported in a simulation of everyday activity. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  13. Intraoperative radiation exposure in spinal scoliosis surgery for pediatric patients using the O-arm® imaging system.

    PubMed

    Kobayashi, Kazuyoshi; Ando, Kei; Ito, Kenyu; Tsushima, Mikito; Morozumi, Masayoshi; Tanaka, Satoshi; Machino, Masaaki; Ota, Kyotaro; Ishiguro, Naoki; Imagama, Shiro

    2018-05-01

    The O-arm ® navigation system allows intraoperative CT imaging that can facilitate highly accurate instrumentation surgery, but radiation exposure is higher than with X-ray radiography. This is a particular concern in pediatric surgery. The purpose of this study is to examine intraoperative radiation exposure in pediatric spinal scoliosis surgery using O-arm. The subjects were 38 consecutive patients (mean age 12.9 years, range 10-17) with scoliosis who underwent spinal surgery with posterior instrumentation using O-arm. The mean number of fused vertebral levels was 11.0 (6-15). O-arm was performed before and after screw insertion, using an original protocol for the cervical, thoracic, and lumbar spine doses. The average scanning range was 6.9 (5-9) intervertebral levels per scan, with 2-7 scans per patient (mean 4.0 scans). Using O-arm, the dose per scan was 92.5 (44-130) mGy, and the mean total dose was 401 (170-826) mGy. This dose was 80.2% of the mean preoperative CT dose of 460 (231-736) mGy (P = 0.11). The total exposure dose and number of scans using intraoperative O-arm correlated strongly and significantly with the number of fused levels; however, there was no correlation with the patient's height. As the fused range became wider, several scans were required for O-arm, and the total radiation exposure became roughly the same as that in preoperative CT. Use of O-arm in our original protocol can contribute to reduction in radiation exposure.

  14. An improved biomechanical model for simulating the strain of the hand-arm system under vibration stress.

    PubMed

    Fritz, M

    1991-01-01

    In order to define relationships between the vibration stress and the strain of the human hand-arm system a biomechanical model was developed. The four masses of the model representing the hand, the forearm and the upper arm were connected by dampers and springs in two perpendicular directions. Simulating muscle activity, damped torsion springs were included additionally. The motions of the model were described by a differential matrix equation which was solved by using a 'transfer matrix routine' as well as by numerical integration. Thus, functions with harmonic or transient time courses could be selected as an excitation. The simulated vibrations were compared with those of other hand-arm models. The forces and torques transmitted between the masses, and the energy dissipated by the dampers were computed for several combinations of exciter frequencies and accelerations. The dependence of torques upon excitation agreed fairly well with the behaviour of the arm muscles under vibration as described by various investigators. At frequencies above 100 Hz the energy was dissipated mainly by the dampers between the masses near to the exciter. Transferring this result to the hand-arm system it shows that at high frequencies energy is dissipated by the hand and its palmar tissues and this might be one cause for the incidence of vibration-induced white finger disease.

  15. Scanning Cloud Radar Observations at the ARM sites

    NASA Astrophysics Data System (ADS)

    Kollias, P.; Clothiaux, E. E.; Shupe, M.; Widener, K.; Bharadwaj, N.; Miller, M. A.; Verlinde, H.; Luke, E. P.; Johnson, K. L.; Jo, I.; Tatarevic, A.; Lamer, K.

    2012-12-01

    Recently, the DOE Atmospheric Radiation Measurement (ARM) program upgraded its fixed and mobile facilities with the acquisition of state-of-the-art scanning, dual-wavelength, polarimetric, Doppler cloud radars. The scanning ARM cloud radars (SACR's) are the most expensive and significant radar systems at all ARM sites and eight SACR systems will be operational at ARM sites by the end of 2013. The SACR's are the primary instruments for the detection of 3D cloud properties (boundaries, volume cloud fractional coverage, liquid water content, dynamics, etc.) beyond the soda-straw (profiling) limited view. Having scanning capabilities with two frequencies and polarization allows more accurate probing of a variety of cloud systems (e.g., drizzle and shallow, warm rain), better correction for attenuation, use of attenuation for liquid water content retrievals, and polarimetric and dual-wavelength ratio characterization of non-spherical particles for improved ice crystal habit identification. Examples of SACR observations from four ARM sites are presented here: the fixed sites at Southern Great Plains (SGP) and North Slope of Alaska (NSA), and the mobile facility deployments at Graciosa Island, Azores and Cape Cod, Massachusetts. The 3D cloud structure is investigated both at the macro-scale (20-50 km) and cloud-scale (100-500 m). Doppler velocity measurements are corrected for velocity folding and are used either to describe the in-cloud horizontal wind profile or the 3D vertical air motions.

  16. Precipitation Estimation from the ARM Distributed Radar Network during the MC3E Campaign

    DOE PAGES

    Giangrande, Scott E.; Collis, Scott; Theisen, Adam K.; ...

    2014-09-12

    This study presents radar-based precipitation estimates collected during the two-month DOE ARM - NASA Midlatitude Continental Convective Clouds Experiment (MC3E). Emphasis is on the usefulness of radar observations from the C-band and X-band scanning ARM precipitation radars (CSAPR, XSAPR) for rainfall estimation products to distances within 100 km of the Oklahoma SGP facility. A dense collection of collocated ARM, NASA GPM and nearby surface Oklahoma Mesonet gauge records are consulted to evaluate potential ARM radar-based hourly rainfall products and campaign optimized methods over individual gauge and areal characterizations. Rainfall products are evaluated against the performance of the regional operational NWSmore » NEXRAD S-band radar polarimetric product. Results indicate that the ARM C-band system may achieve similar point and areal-gauge bias and root mean square (rms) error performance to the NEXRAD standard for the variety of MC3E deep convective events sampled when capitalizing on differential phase measurements. The best campaign rainfall performance was achieved when applying radar relations capitalizing on estimates of the specific attenuation from the CSAPR system. The ARM X-band systems only demonstrate solid capabilities as compared to NEXRAD standards for hourly point and areal rainfall accumulations under 10 mm. Here, all methods exhibit a factor of 1.5 to 2.5 reduction in rms errors for areal accumulations over a 15 km2 NASA dense network housing 16 sites having collocated bucket gauges, with the higher error reductions best associated with polarimetric methods.« less

  17. Precipitation Estimation from the ARM Distributed Radar Network during the MC3E Campaign

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giangrande, Scott E.; Collis, Scott; Theisen, Adam K.

    This study presents radar-based precipitation estimates collected during the two-month DOE ARM - NASA Midlatitude Continental Convective Clouds Experiment (MC3E). Emphasis is on the usefulness of radar observations from the C-band and X-band scanning ARM precipitation radars (CSAPR, XSAPR) for rainfall estimation products to distances within 100 km of the Oklahoma SGP facility. A dense collection of collocated ARM, NASA GPM and nearby surface Oklahoma Mesonet gauge records are consulted to evaluate potential ARM radar-based hourly rainfall products and campaign optimized methods over individual gauge and areal characterizations. Rainfall products are evaluated against the performance of the regional operational NWSmore » NEXRAD S-band radar polarimetric product. Results indicate that the ARM C-band system may achieve similar point and areal-gauge bias and root mean square (rms) error performance to the NEXRAD standard for the variety of MC3E deep convective events sampled when capitalizing on differential phase measurements. The best campaign rainfall performance was achieved when applying radar relations capitalizing on estimates of the specific attenuation from the CSAPR system. The ARM X-band systems only demonstrate solid capabilities as compared to NEXRAD standards for hourly point and areal rainfall accumulations under 10 mm. Here, all methods exhibit a factor of 1.5 to 2.5 reduction in rms errors for areal accumulations over a 15 km2 NASA dense network housing 16 sites having collocated bucket gauges, with the higher error reductions best associated with polarimetric methods.« less

  18. Biotin

    MedlinePlus

    ... mouth. Other symptoms include depression, lack of interest, hallucinations, and tingling in the arms and legs. Low ... and mouth. Nervous system symptoms include depression, exhaustion, hallucinations, and tingling of the arms and legs. There ...

  19. Laparoscopic telesurgery between the United States and Singapore.

    PubMed

    Lee, B R; Png, D J; Liew, L; Fabrizio, M; Li, M K; Jarrett, J W; Kavoussi, L R

    2000-09-01

    Telemedicine is the use of electronic digital signals to transfer information from one site to another. With the advent of a telepresence operative system and development of remote robotic arms to hold and manoeuvre the laparoscope, telemedicine is finding its role in surgery, especially laparoscopic surgery. CLINICAL FEATURES AND TREATMENT: We report two successful cases of laparoscopic surgery--radical nephrectomy and varicocelectomy for a 3-cm renal tumour and for bilateral varicoceles causing pain, where a less experienced laparoscopic surgeon in Singapore was telementored by an experienced laparoscopic surgeon located remotely in the United States. Both patients recovered uneventfully and returned home on postoperative day 4 and on the day of surgery, respectively. This study demonstrates that telementored laparoscopic systems are feasible and safe, between countries halfway across the world. As the Internet expands in utility and the cost of higher bandwidth telecommunication lines decreases, even to remote countries, telementoring systems will become more affordable and may potentially pave the way for advanced surgical and laparoscopic applications and training for the future.

  20. Distinct Trends of DNA Methylation Patterning in the Innate and Adaptive Immune Systems

    PubMed Central

    Schuyler, Ronald P.; Merkel, Angelika; Raineri, Emanuele; Altucci, Lucia; Vellenga, Edo; Martens, Joost H.A.; Pourfarzad, Farzin; Kuijpers, Taco W.; Burden, Frances; Farrow, Samantha; Downes, Kate; Ouwehand, Willem H.; Clarke, Laura; Datta, Avik; Lowy, Ernesto; Flicek, Paul; Frontini, Mattia; Stunnenberg, Hendrik G.; Martín-Subero, José I.; Gut, Ivo; Heath, Simon

    2018-01-01

    Summary DNA methylation and the localization and post-translational modification of nucleosomes are interdependent factors that contribute to the generation of distinct phenotypes from genetically identical cells. With 112 whole-genome bisulfite sequencing datasets from the BLUEPRINT Epigenome Project, we analyzed the global development of DNA methylation patterns during lineage commitment and maturation of a range of immune system effector cells and the cancers that arise from them. We show clear trends in methylation patterns that are distinct in the innate and adaptive arms of the human immune system, both globally and in relation to consistently positioned nucleosomes. Most notable are a progressive loss of methylation in developing lymphocytes and the consistent occurrence of non-CG methylation in specific cell types. Cancer samples from the two lineages are further polarized, suggesting the involvement of distinct lineage-specific epigenetic mechanisms. We anticipate broad utility for this resource as a basis for further comparative epigenetic analyses. PMID:27851971

  1. Distinct Trends of DNA Methylation Patterning in the Innate and Adaptive Immune Systems.

    PubMed

    Schuyler, Ronald P; Merkel, Angelika; Raineri, Emanuele; Altucci, Lucia; Vellenga, Edo; Martens, Joost H A; Pourfarzad, Farzin; Kuijpers, Taco W; Burden, Frances; Farrow, Samantha; Downes, Kate; Ouwehand, Willem H; Clarke, Laura; Datta, Avik; Lowy, Ernesto; Flicek, Paul; Frontini, Mattia; Stunnenberg, Hendrik G; Martín-Subero, José I; Gut, Ivo; Heath, Simon

    2016-11-15

    DNA methylation and the localization and post-translational modification of nucleosomes are interdependent factors that contribute to the generation of distinct phenotypes from genetically identical cells. With 112 whole-genome bisulfite sequencing datasets from the BLUEPRINT Epigenome Project, we analyzed the global development of DNA methylation patterns during lineage commitment and maturation of a range of immune system effector cells and the cancers that arise from them. We show clear trends in methylation patterns that are distinct in the innate and adaptive arms of the human immune system, both globally and in relation to consistently positioned nucleosomes. Most notable are a progressive loss of methylation in developing lymphocytes and the consistent occurrence of non-CG methylation in specific cell types. Cancer samples from the two lineages are further polarized, suggesting the involvement of distinct lineage-specific epigenetic mechanisms. We anticipate broad utility for this resource as a basis for further comparative epigenetic analyses. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  2. Accuracy of digital arm and wrist manometers: clinical implications for the dental hygienist.

    PubMed

    Furgeson, Danielle; Mickels-Foster, Nancy

    2013-10-01

    Utilization of digital manometers chairside is fast becoming a standard of care in dental hygiene education. It is imperative to ensure accurate blood pressure measurements regardless of modality to avoid medical emergencies in the dental chair. This study sought to determine the accuracy of the automated digital arm and wrist cuffs utilized by students in the University of Maine at Augusta, Bangor Campus Dental Health Programs' dental hygiene clinic. After institutional review board approval, 121 subjects were recruited, with 21 excluded for a total of 100 subjects. Subjects were randomly assigned to different test modalities upon check-in. Initial blood pressure measurements were taken with a calibrated aneroid control device by a principal investigator. A second measurement was taken with the randomized arm or wrist manometer 5 minutes later. Investigators were blinded to the modality of test manometer and measurements obtained from the second reading. All readings were taken according to manufacturers' instructions to ensure technique consistency. Data indicated lower readings for each modality from the control for both systolic and diastolic measurements. The differences in the systolic and diastolic readings for the wrist modality were significantly lower than the control with (p= 0.000) and (p=0.000), respectively. Automated digital manometers should be used with caution as a screening tool in the dental setting, particularly when administration of pharmacological agents such as local anesthesia may be used during the course of treatment. These automated modalities should not be used for patients with cardiac or hypertensive conditions.

  3. ML Crew Access Arm Move

    NASA Image and Video Library

    2017-10-16

    The Orion crew access arm departs Precision Fabricating and Cleaning in Cocoa, Florida, atop a flatbed truck. The access arm is transported to a storage location at NASA's Kennedy Space Center in Florida. Later this month, the arm will be transported to the mobile launcher (ML) tower at the center. The crew access arm will be located at about the 274-foot level on the tower. It will rotate from its retracted position and interface with the Orion crew hatch location to provide entry to the Orion crew module. The Ground Systems Development and Operations Program is overseeing installation of umbilicals and launch accessories on the ML tower.

  4. CT imaging with a mobile C-arm prototype

    NASA Astrophysics Data System (ADS)

    Cheryauka, Arvi; Tubbs, David; Langille, Vinton; Kalya, Prabhanjana; Smith, Brady; Cherone, Rocco

    2008-03-01

    Mobile X-ray imagery is an omnipresent tool in conventional musculoskeletal and soft tissue applications. The next generation of mobile C-arm systems can provide clinicians of minimally-invasive surgery and pain management procedures with both real-time high-resolution fluoroscopy and intra-operative CT imaging modalities. In this study, we research two C-arm CT experimental system configurations and evaluate their imaging capabilities. In a non-destructive evaluation configuration, the X-ray Tube - Detector assembly is stationary while an imaging object is placed on a rotating table. In a medical imaging configuration, the C-arm gantry moves around the patient and the table. In our research setting, we connect the participating devices through a Mobile X-Ray Imaging Environment known as MOXIE. MOXIE is a set of software applications for internal research at GE Healthcare - Surgery and used to examine imaging performance of experimental systems. Anthropomorphic phantom volume renderings and orthogonal slices of reconstructed images are obtained and displayed. The experimental C-arm CT results show CT-like image quality that may be suitable for interventional procedures, real-time data management, and, therefore, have great potential for effective use on the clinical floor.

  5. Near infrared spectroscopy of human muscles

    NASA Astrophysics Data System (ADS)

    Gasbarrone, R.; Currà, A.; Cardillo, A.; Bonifazi, G.; Serranti, S.

    2018-02-01

    Optical spectroscopy is a powerful tool in research and industrial applications. Its properties of being rapid, non-invasive and not destructive make it a promising technique for qualitative as well as quantitative analysis in medicine. Recent advances in materials and fabrication techniques provided portable, performant, sensing spectrometers readily operated by user-friendly cabled or wireless systems. We used such a system to test whether infrared spectroscopy techniques, currently utilized in many areas as primary/secondary raw materials sector, cultural heritage, agricultural/food industry, environmental remote and proximal sensing, pharmaceutical industry, etc., could be applied in living humans to categorize muscles. We acquired muscles infrared spectra in the Vis-SWIR regions (350-2500 nm), utilizing an ASD FieldSpec 4 Standard-Res Spectroradiometer with a spectral sampling capability of 1.4 nm at 350-1000 nm and 1.1 nm at 1001-2500 nm. After a preliminary spectra pre-processing (i.e. signal scattering reduction), Principal Component Analysis (PCA) was applied to identify similar spectral features presence and to realize their further grouping. Partial Least-Squares Discriminant Analysis (PLS-DA) was utilized to implement discrimination/prediction models. We studied 22 healthy subjects (age 25-89 years, 11 females), by acquiring Vis-SWIR spectra from the upper limb muscles (i.e. biceps, a forearm flexor, and triceps, a forearm extensor). Spectroscopy was performed in fixed limb postures (elbow angle approximately 90‡). We found that optical spectroscopy can be applied to study human tissues in vivo. Vis-SWIR spectra acquired from the arm detect muscles, distinguish flexors from extensors.

  6. A comparative study on the CT effective dose for various positions of the patient's arm

    NASA Astrophysics Data System (ADS)

    Seong, Ji-Hye; Park, Soon-Ki; Kim, Jung-Sun; Jung, Woo-Young; Kim, Ho-Sung; Dong, Kyung-Rae; Chung, Woon-Kwan; Cho, Jae-Hwan; Cho, Young-Kuk

    2012-10-01

    In a whole body PET/CT (positron emission tomography/computed tomography) scan, lifting the patient's arm to improve the image quality is natural. On the other hand, the arms should be placed lower when the lesion is located in the head and neck. This study compared the CT effective dose for each arm position after applying AEC (automatic exposure control). Forty-five patients who had undergone an 18F-FDG (fluorine-18-fluoro deoxy glucose) whole body PET/CT scan were examined using Biograph Truepoint 40, Biograph Sensation 16, and Discovery STe 8 systems. The CT effective dose of 15 patients for each set of equipment was measured and analyzed comparatively in both the arm-lifted and arm-lowered positions. The ImPACT Ver. 1.0 program was used to measure the CT effective dose. A paired t-test (SPSS 18.0 statistic program) was applied for statistical analysis. In the case of the arm-lifted position, the CT effective dose measured for Biograph 40, Biograph 16, and DSTe 8 systems were 6.33 ± 0.93 mSv, 8.01 ± 1.34 mSv, and 9.69 ± 2.32 mSv, respectively. When the arms were located in the lower position, the respective CT effective doses were 6.97 ± 0.76 mSv, 8.95 ± 1.85 mSv, and 13.07 ± 2.87 mSv, respectively. These results revealed 9.2%, 10.5%, and 25.9% improvement in the CT effective doses for the Biograph 40, Biograph 16 and DSTe 8 systems, respectively, when the arms were raised compared to that when they were lowered (p < 0.05). For the whole body PET/CT case, the CT effective dose applying AEC showed a mean 15.2% decrease in the radiation exposure of the patients when the arm was lifted. The patient with no lesion in the head and neck would show fewer artifacts in the objective part and a lower CT effective dose. For a patient with a lesion in the head and neck, the artifacts in the objective part can be reduced by putting the arms down. The fact that the CT effective dose is increased in a whole-body PET/CT scan should be a concern.

  7. Enhanced Gravity Tractor Derived from the Asteroid Redirect Mission for Deflecting Hypothetical Asteroid 2017 PDC

    NASA Technical Reports Server (NTRS)

    Mazanek, Daniel D.; Reeves, David M.; Abell, Paul A.; Shen, Haijun; Qu, Min

    2017-01-01

    The Asteroid Redirect Mission (ARM) concept would robotically visit a hazardous-size near-Earth asteroid (NEA) with a rendezvous spacecraft, collect a multi-ton boulder and regolith samples from its surface, demonstrate an innovative planetary defense technique known as the Enhanced Gravity Tractor (EGT), and return the asteroidal material to a stable orbit around the Moon, allowing astronauts to explore the returned material in the mid-2020s. Launch of the robotic vehicle to rendezvous with the ARM reference target, NEA (341843) 2008 EV5, would occur in late 2021 [1,2]. The robotic segment of the ARM concept uses a 40 kW Solar Electric Propulsion (SEP) system with a specific impulse (Isp) of 2600 s, and would provide the first ever demonstration of the EGT technique on a hazardous-size asteroid and validate one method of collecting mass in-situ. The power, propellant, and thrust capability of the ARM robotic spacecraft can be scaled from a 40 kW system to 150 kW and 300 kW, which represent a likely future power level progression. The gravity tractor technique uses the gravitational attraction of a station-keeping spacecraft with the asteroid to provide a velocity change and gradually alter the trajectory of the asteroid. EGT utilizes a spacecraft with a high-efficiency propulsion system, such as Solar Electric Propulsion (SEP), along with mass collected in-situ to augment the mass of the spacecraft, thereby increasing the gravitational force between the objects [3]. As long as the spacecraft has sufficient thrust and propellant capability, the EGT force is only limited by the amount of in-situ mass collected and can be increased several orders of magnitude compared to the traditional gravity tractor technique in which only the spacecraft mass is used to generate the gravitational attraction force. This increase in available force greatly reduces the required deflection time. The collected material can be a single boulder, multiple boulders, regolith, or a combination of different material types using a variety of collection techniques. The EGT concept assumes that the ability to efficiently collect asteroid mass in-situ from a wide variety of asteroid types and environments is a future capability that will be developed and perfected in the future by the asteroid mining community. Additionally, it is anticipated that the mass collection would likely be performed by a single or multiple separable spacecraft to allow the SEP spacecraft to operate at safe distance from the asteroid.

  8. Occupant thorax response variations due to arm position and restraint systems in side impact crash scenarios.

    PubMed

    Gierczycka, Donata; Cronin, Duane S

    2017-09-01

    Recent epidemiological studies have identified that thoracic side airbags may vary in efficacy to reduce injury severity in side impact crash scenarios, while previous experimental and epidemiological studies have presented contrasting results. This study aimed to quantify the variations in occupant response in side impact conditions using a human body computational model integrated with a full vehicle model. The model was analyzed for a Moving Deformable Barrier side impact at 61km/h to assess two pre-crash arm positions, the incorporation of a seatbelt, and a thorax air bag on thorax response. The occupant response was evaluated using chest compression, the viscous criterion and thoracic spinal curvature. The arm position accounted for largest changes in the thorax response (106%) compared to the presence of the airbag and seatbelt systems (75%). It was also noted that the results were dependant on the method and location of thorax response measurement and this should be investigated further. Assessment using lateral displacement of the thoracic spine correlated positively with chest compression and Viscous Criterion, with the benefit of evaluating whole thorax response and provides a useful metric to compare occupant response for different side impact safety systems. The thoracic side airbag was found to increase the chest compression for the driving arm position (+70%), and reduced the injury metrics for the vertical arm position (-17%). This study demonstrated the importance of occupant arm position on variability in thoracic response, and provides insight for future design and optimization of side impact safety systems. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Pharmacist-led management of chronic pain in primary care: results from a randomised controlled exploratory trial

    PubMed Central

    Bruhn, Hanne; Bond, Christine M; Elliott, Alison M; Hannaford, Philip C; Lee, Amanda J; McNamee, Paul; Smith, Blair H; Watson, Margaret C; Holland, Richard; Wright, David

    2013-01-01

    Objectives To compare the effectiveness of pharmacist medication review, with or without pharmacist prescribing, with standard care, for patients with chronic pain. Design An exploratory randomised controlled trial. Setting Six general practices with prescribing pharmacists in Grampian (3) and East Anglia (3). Participants Patients on repeat prescribed pain medication (4815) were screened by general practitioners (GPs), and mailed invitations (1397). 196 were randomised and 180 (92%) completed. Exclusion criteria included: severe mental illness, terminally ill, cancer related pain, history of addiction. Randomisation and intervention Patients were randomised using a remote telephone service to: (1) pharmacist medication review with face-to-face pharmacist prescribing; (2) pharmacist medication review with feedback to GP and no planned patient contact or (3) treatment as usual (TAU). Blinding was not possible. Outcome measures Outcomes were the SF-12v2, the Chronic Pain Grade (CPG), the Health Utilities Index 3 and the Hospital Anxiety and Depression Scale (HADS). Outcomes were collected at 0, 3 and 6 months. Results In the prescribing arm (n=70) two patients were excluded/nine withdrew. In the review arm (n=63) one was excluded/three withdrew. In the TAU arm (n=63) four withdrew. Compared with baseline, patients had an improved CPG in the prescribing arm, 47.7% (21/44; p=0.003) and in the review arm, 38.6% (17/44; p=0.001), but not the TAU group, 31.3% (15/48; ns). The SF-12 Physical Component Score showed no effect in the prescribing or review arms but improvement in TAU (p=0.02). The SF-12 Mental Component Score showed no effect for the prescribing or review arms and deterioration in the TAU arm (p=0.002). HADS scores improved within the prescribing arm for depression (p=0.022) and anxiety (p=0.007), between groups (p=0.022 and p=0.045, respectively). Conclusions This is the first randomised controlled trial of pharmacist prescribing in the UK, and suggests that there may be a benefit for patients with chronic pain. A larger trial is required. Trial registration: www.isrctn.org/ISRCTN06131530. Medical Research Council funding. PMID:23562814

  10. CD22 and Siglec-G in B cell function and tolerance

    PubMed Central

    Poe, Jonathan C.; Tedder, Thomas F.

    2012-01-01

    The immune system has evolved into two main arms, the primitive innate arm that is the first line of defense but relatively short-lived and broad acting, and the advanced adaptive arm that generates immunologic “memory” allowing rapid, specific recall responses. T cell-independent type-2 (TI-2) antigens (Ags) invoke innate immune responses. However, due to its “at the ready” nature, how the innate arm of the immune system maintains tolerance to potentially abundant host TI-2 Ags remains elusive. Therefore, it is important to define the mechanisms that establish innate immune tolerance. This review highlights recent insights into B cell tolerance to theoretical self TI-2 Ags, and examines how the B cell-restricted Siglecs, CD22 and Siglec-G, might contribute to this process. PMID:22677186

  11. Comparison of tongue interface with keyboard for control of an assistive robotic arm.

    PubMed

    Struijk, Lotte N S Andreasen; Lontis, Romulus

    2017-07-01

    This paper demonstrates how an assistive 6 DoF robotic arm with a gripper can be controlled manually using a tongue interface. The proposed method suggests that it possible for a user to manipulate the surroundings with his or her tongue using the inductive tongue control system as deployed in this study. The sensors of an inductive tongue-computer interface were mapped to the Cartesian control of an assistive robotic arm. The resulting control system was tested manually in order to compare manual control of the robot using a standard keyboard and using the tongue interface. Two healthy subjects controlled the robotic arm to precisely move a bottle of water from one location to another. The results shows that the tongue interface was able to fully control the robotic arm in a similar manner as the standard keyboard resulting in the same number of successful manipulations and an average increase in task duration of up to 30% as compared with the standard keyboard.

  12. C-arm technique using distance driven method for nephrolithiasis and kidney stones detection

    NASA Astrophysics Data System (ADS)

    Malalla, Nuhad; Sun, Pengfei; Chen, Ying; Lipkin, Michael E.; Preminger, Glenn M.; Qin, Jun

    2016-04-01

    Distance driven represents a state of art method that used for reconstruction for x-ray techniques. C-arm tomography is an x-ray imaging technique that provides three dimensional information of the object by moving the C-shaped gantry around the patient. With limited view angle, C-arm system was investigated to generate volumetric data of the object with low radiation dosage and examination time. This paper is a new simulation study with two reconstruction methods based on distance driven including: simultaneous algebraic reconstruction technique (SART) and Maximum Likelihood expectation maximization (MLEM). Distance driven is an efficient method that has low computation cost and free artifacts compared with other methods such as ray driven and pixel driven methods. Projection images of spherical objects were simulated with a virtual C-arm system with a total view angle of 40 degrees. Results show the ability of limited angle C-arm technique to generate three dimensional images with distance driven reconstruction.

  13. Control method and system for hydraulic machines employing a dynamic joint motion model

    DOEpatents

    Danko, George [Reno, NV

    2011-11-22

    A control method and system for controlling a hydraulically actuated mechanical arm to perform a task, the mechanical arm optionally being a hydraulically actuated excavator arm. The method can include determining a dynamic model of the motion of the hydraulic arm for each hydraulic arm link by relating the input signal vector for each respective link to the output signal vector for the same link. Also the method can include determining an error signal for each link as the weighted sum of the differences between a measured position and a reference position and between the time derivatives of the measured position and the time derivatives of the reference position for each respective link. The weights used in the determination of the error signal can be determined from the constant coefficients of the dynamic model. The error signal can be applied in a closed negative feedback control loop to diminish or eliminate the error signal for each respective link.

  14. Advanced design for orbital debris removal in support of solar system exploration

    NASA Technical Reports Server (NTRS)

    1991-01-01

    The development of an Autonomous Space Processor for Orbital Debris (ASPOD) is the ultimate goal. The craft will process, in situ, orbital debris using resources available in low Earth orbit (LEO). The serious problem of orbital debris is briefly described and the nature of the large debris population is outlined. This year, focus was on development of a versatile robotic manipulator to augment an existing robotic arm; incorporation of remote operation of robotic arms; and formulation of optimal (time and energy) trajectory planning algorithms for coordinating robotic arms. The mechanical design of the new arm is described in detail. The versatile work envelope is explained showing the flexibility of the new design. Several telemetry communication systems are described which will enable the remote operation of the robotic arms. The trajectory planning algorithms are fully developed for both the time-optimal and energy-optimal problem. The optimal problem is solved using phase plane techniques while the energy optimal problem is solved using dynamics programming.

  15. Infomax Strategies for an Optimal Balance Between Exploration and Exploitation

    NASA Astrophysics Data System (ADS)

    Reddy, Gautam; Celani, Antonio; Vergassola, Massimo

    2016-06-01

    Proper balance between exploitation and exploration is what makes good decisions that achieve high reward, like payoff or evolutionary fitness. The Infomax principle postulates that maximization of information directs the function of diverse systems, from living systems to artificial neural networks. While specific applications turn out to be successful, the validity of information as a proxy for reward remains unclear. Here, we consider the multi-armed bandit decision problem, which features arms (slot-machines) of unknown probabilities of success and a player trying to maximize cumulative payoff by choosing the sequence of arms to play. We show that an Infomax strategy (Info-p) which optimally gathers information on the highest probability of success among the arms, saturates known optimal bounds and compares favorably to existing policies. Conversely, gathering information on the identity of the best arm in the bandit leads to a strategy that is vastly suboptimal in terms of payoff. The nature of the quantity selected for Infomax acquisition is then crucial for effective tradeoffs between exploration and exploitation.

  16. The Road to Information Dominance: "System of Systems" Concept for the United States Armed Forces.

    DTIC Science & Technology

    1998-04-06

    information dominance through the U.S. Armed Forces "System of Systems" concept. It addresses and analyzes current and future strategic implications and requirements for U.S. warfighting communications and information systems. It proposes a more flexible, reliable, responsive, robust and survivable high capacity throughput communications and "bitways" system to support future force projection operations for the Force and/or Army After Next. Lastly, it concludes with a suggested methodology to implement the "System of Systems" concept to enable

  17. Land Combat Systems Industry. Industry Study, Spring 2009

    DTIC Science & Technology

    2009-01-01

    Spring 2009 Industry Study Final Report Land Combat Systems Industry The Industrial College of the Armed Forces...AND SUBTITLE Spring 2009. Industry Study. Land Combat Systems Industry 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6 . AUTHOR(S...Industrial College of the Armed Forces,Washington,DC,20319 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS

  18. The globalization of the arms industry: The next proliferation challenge

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bitzinger, R.A.

    1994-12-31

    The globalization of the arms industry entails a significant shift away from traditional, single-country patterns of weapons production toward internationalization of the development, production, and marketing of arms. While wholly indigenous armaments production may be on the decline, multinational arms production - through collaboration on individual weapon systems and increasingly via interfirm linkages across the international arms industry - appears actually to be expanding. In several instances, in fact, multinational armaments production is increasingly supplementing or even supplanting indigenous or autonomous weapons production or arms imports. The emergence of an increasingly transnational defense technology and industrial base is fundamentally affectingmore » the shape and content of much of the global arms trade. This changing defense market, in turn, will have a profound impact on a number of national security issues concerning the Western industrialized nations. 3 figs., 2 tabs.« less

  19. ARM Airborne Carbon Measurements VI (ARM-ACME VI) Field Campaign Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Biraud, Sebastien

    2017-05-01

    From October 1, 2015 through September 30, 2016, AAF deployed a Cessna 206 aircraft over the Southern Great Plains, collecting observations of trace gas mixing ratios over the ARM/SGP Central Facility. The aircraft payload included two Atmospheric Observing Systems (AOS Inc.) analyzers for continuous measurements of CO2, and a 12-flask sampler for analysis of carbon cycle gases (CO2, CO, CH4, N2O, 13CO2). The aircraft payload also includes solar/infrared radiation measurements. This research (supported by DOE ARM and TES programs) builds upon previous ARM-ACME missions. The goal of these measurements is to improve understanding of: (a) the carbon exchange of themore » ARM region; (b) how CO2 and associated water and energy fluxes influence radiative forcing, convective processes, and CO2 concentrations over the ARM region, and (c) how greenhouse gases are transported on continental scales.« less

  20. System and method for controlling a vision guided robot assembly

    DOEpatents

    Lin, Yhu-Tin; Daro, Timothy; Abell, Jeffrey A.; Turner, III, Raymond D.; Casoli, Daniel J.

    2017-03-07

    A method includes the following steps: actuating a robotic arm to perform an action at a start position; moving the robotic arm from the start position toward a first position; determining from a vision process method if a first part from the first position will be ready to be subjected to a first action by the robotic arm once the robotic arm reaches the first position; commencing the execution of the visual processing method for determining the position deviation of the second part from the second position and the readiness of the second part to be subjected to a second action by the robotic arm once the robotic arm reaches the second position; and performing a first action on the first part using the robotic arm with the position deviation of the first part from the first position predetermined by the vision process method.

Top