USDA-ARS?s Scientific Manuscript database
A method for the identification and quantification of citrus limonoid glucosides in juices based upon high performance liquid chromatography (HPLC) separation coupled to post-column reaction with Ehrlichs’s reagent has been developed. This method utilizes a phenyl stationary phase and an isocratic ...
ERIC Educational Resources Information Center
Smith, Eugene T.; Hill, Marc
2011-01-01
In this laboratory exercise, students develop a LabVIEW-controlled high-performance liquid chromatography system utilizing a data acquisition device, two pumps, a detector, and fraction collector. The programming experience involves a variety of methods for interface communication, including serial control, analog-to-digital conversion, and…
USDA-ARS?s Scientific Manuscript database
We developed a rapid method with ultra-performance liquid chromatography – tandem mass spectrometry (UPLC-MS/MS) for the qualitative and quantitative analysis of plant proanthocyanidins (PAs) directly from crude plant extracts. The method utilizes a range of cone voltages to achieve the depolymeriza...
USDA-ARS?s Scientific Manuscript database
The pigment, 8-O-methylbostrycoidin is a polyketide metabolite produced by multiple species of the fungus Fusarium that infects plant crops, including maize. A technique was developed for the analysis of 8-O-methylbostrycoidin by high performance liquid chromatography coupled to electrospray ionizat...
A method for the detection of trace levels of N,N-diethyl-m-toluamide (DEET) in water is discussed. The method utilizes an on-line preconcentration column in series with high performance liquid chromatography (HPLC) and UV photodiode array detection. DEET, a common insect repel...
Borovcová, Lucie; Pauk, Volodymyr; Lemr, Karel
2018-05-01
New psychoactive substances represent serious social and health problem as tens of new compounds are detected in Europe annually. They often show structural proximity or even isomerism, which complicates their analysis. Two methods based on ultra high performance supercritical fluid chromatography and ultra high performance liquid chromatography with mass spectrometric detection were validated and compared. A simple dilute-filter-and-shoot protocol utilizing propan-2-ol or methanol for supercritical fluid or liquid chromatography, respectively, was proposed to detect and quantify 15 cathinones and phenethylamines in human urine. Both methods offered fast separation (<3 min) and short total analysis time. Precision was well <15% with a few exceptions in liquid chromatography. Limits of detection in urine ranged from 0.01 to 2.3 ng/mL, except for cathinone (5 ng/mL) in supercritical fluid chromatography. Nevertheless, this technique distinguished all analytes including four pairs of isomers, while liquid chromatography was unable to resolve fluoromethcathinone regioisomers. Concerning matrix effects and recoveries, supercritical fluid chromatography produced more uniform results for different compounds and at different concentration levels. This work demonstrates the performance and reliability of supercritical fluid chromatography and corroborates its applicability as an alternative tool for analysis of new psychoactive substances in biological matrixes. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Liang, Tu; Fu, Qing; Li, Fangbing; Zhou, Wei; Xin, Huaxia; Wang, Hui; Jin, Yu; Liang, Xinmiao
2015-08-01
A systematic strategy based on hydrophilic interaction liquid chromatography was developed for the separation, purification and quantification of raffinose family oligosaccharides from Lycopus lucidus Turcz. Methods with enough hydrophilicity and selectivity were utilized to resolve the problems encountered in the separation of oligosaccharides such as low retention, low resolution and poor solubility. The raffinose family oligosaccharides in L. lucidus Turcz. were isolated using solid-phase extraction followed by hydrophilic interaction liquid chromatography at semi-preparative scale to obtain standards of stachyose, verbascose and ajugose. Utilizing the obtained oligosaccharides as standards, a quantitative determination method was developed, validated and applied for the content determination of raffinose family oligosaccharides both in the aerial and root parts of L. lucidus Turcz. There were no oligosaccharides in the aerial parts, while in the root parts, the total content was 686.5 mg/g with the average distribution: raffinose 66.5 mg/g, stachyose 289.0 mg/g, verbascose 212.4 mg/g, and ajugose 118.6 mg/g. The result provided the potential of roots of L. lucidus Turcz. as new raffinose family oligosaccharides sources for functional food. Moreover, since the present systematic strategy is efficient, sensitive and robust, separation, purification and quantification of oligosaccharides by hydrophilic interaction liquid chromatography seems to be possible. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Shak, S
1987-01-01
LTB4 and its omega-oxidation products may be rapidly, sensitively, and specifically quantitated by the methods of solid-phase extraction and reversed-phase high-performance liquid chromatography (HPLC), which are described in this chapter. Although other techniques, such as radioimmunoassay or gas chromatography-mass spectrometry, may be utilized for quantitative analysis of the lipoxygenase products of arachidonic acid, only the technique of reversed-phase HPLC can quantitate as many as 10 metabolites in a single analysis, without prior derivatization. In this chapter, we also reviewed the chromatographic theory which we utilized in order to optimize reversed-phase HPLC analysis of LTB4 and its omega-oxidation products. With this information and a gradient HPLC system, it is possible for any investigator to develop a powerful assay for the potent inflammatory mediator, LTB4, or for any other lipoxygenase product of arachidonic acid.
2013-02-11
calibration curves was ±5%. Ion chromatography (IC) was used for analysis of perchlorate and other ionic targets. Analysis was carried out on a...The methods utilize liquid or gas chromatography , techniques that do not lend themselves well to portable devices and methods. Portable methods are...
2011-01-01
THIS PAGE unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 liquid or gas chromatography and do not Icnd themselves well...typically compatible with gas or liquid chromatography , and equilibration times can be lengthy. Other solid-phase extraction pTOtoools have utilized a...aniH M"X vr sat,~rat io~ of> an ~quifer o.r. soi ~. Surface water often contains from sea water was similar to recovery from deionized waier for ,:’ a
Hu, J-Y; Deng, Z-B; Qin, D-M
2009-12-01
JS-118 is a diacylhydrazines-type insect growth regulator used extensively in China now. An analytical method for residues determination of JS-118 in cabbage and soil samples by high performance liquid chromatography with DAD detection was established and optimized. Primary secondary amine solid phase extraction cartridge was used for sample preparation. Mean recoveries for the analyte ranged from 96.6% to 107.0% with CV value less than 4.7%. The limit of quantification is 0.01 mg/kg. Direct confirmation of JS-118 residues in samples was realized by high performance liquid chromatography-mass spectrometry. The proposed method is simple, rapid and reliable to perform and could be utilized for monitoring of pesticides residues.
We used chromatography modeling software to assist in HPLC method development, with the goal
of enhancing separations through the exclusive use of gradient time and column temperature. We
surveyed nine stationary phases for their utility in pigment purification and natur...
Comprehensive Urine Drug Screen by Gas Chromatography/Mass Spectrometry (GC/MS).
Ramoo, Bheemraj; Funke, Melissa; Frazee, Clint; Garg, Uttam
2016-01-01
Drug screening is an essential component of clinical toxicology laboratory service. Some laboratories use only automated chemistry analyzers for limited screening of drugs of abuse and few other drugs. Other laboratories use a combination of various techniques such as immunoassays, colorimetric tests, and mass spectrometry to provide more detailed comprehensive drug screening. Mass spectrometry, gas or liquid, can screen for hundreds of drugs and is often considered the gold standard for comprehensive drug screening. We describe an efficient and rapid gas chromatography/mass spectrometry (GC/MS) method for comprehensive drug screening in urine which utilizes a liquid-liquid extraction, sample concentration, and analysis by GC/MS.
USDA-ARS?s Scientific Manuscript database
A contact closure system has been constructed and implemented that utilizes two contact closure sender boards that communicate wirelessly to four contact closure receiver boards to distribute start signals from two or three liquid chromatographs to fourteen instruments, pumps, detectors, or other co...
Analysis of street drugs in seized material without primary reference standards.
Laks, Suvi; Pelander, Anna; Vuori, Erkki; Ali-Tolppa, Elisa; Sippola, Erkki; Ojanperä, Ilkka
2004-12-15
A novel approach was used to analyze street drugs in seized material without primary reference standards. Identification was performed by liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS), essentially based on accurate mass determination using a target library of 735 exact monoisotopic masses. Quantification was carried out by liquid chromatography/chemiluminescence nitrogen detection (LC/CLND) with a single secondary standard (caffeine), utilizing the detector's equimolar response to nitrogen. Sample preparation comprised dilution, first with methanol and further with the LC mobile phase. Altogether 21 seized drug samples were analyzed blind by the present method, and results were compared to accredited reference methods utilizing identification by gas chromatography/mass spectrometry and quantification by gas chromatography or liquid chromatography. The 31 drug findings by LC/TOFMS comprised 19 different drugs-of-abuse, byproducts, and adulterants, including amphetamine and tryptamine designer drugs, with one unresolved pair of compounds having an identical mass. By the reference methods, 27 findings could be confirmed, and among the four unconfirmed findings, only 1 apparent false positive was found. In the quantitative analysis of 11 amphetamine, heroin, and cocaine findings, mean relative difference between the results of LC/CLND and the reference methods was 11% (range 4.2-21%), without any observable bias. Mean relative standard deviation for three parallel LC/CLND results was 6%. Results suggest that the present combination of LC/TOFMS and LC/CLND offers a simple solution for the analysis of scheduled and designer drugs in seized material, independent of the availability of primary reference standards.
Hu, Lei; Lv, Zhenhua; Li, Gao; Xu, Xiaolong; Zhang, Chenghao; Cao, Peng; Huang, Jiangeng; Si, Luqin
2015-06-01
TJ0711 (1-[4-(2-methoxyethyl)phenoxy]-3-[2-(2-methoxyphenoxy)ethylamino]-2-propanol) is a novel β-adrenoreceptor blocker with vasodilating activity. The aim of this study was to investigate the in vitro metabolic properties of TJ0711 from both qualitative and quantitative aspects using mouse, rat, dog, and human liver microsomes as well as rat hepatocytes. Two modern liquid chromatography with tandem mass spectrometry systems, ultra high performance liquid chromatography with quadrupole time-of-flight mass spectrometry and ultra fast liquid chromatography with quadrupole linear ion trap mass spectrometry, were utilized for the analysis. To better characterize the metabolic pathways of TJ0711, two major metabolites were incubated under the same conditions as that for TJ0711. TJ0711 was extensively metabolized in vitro, and a total of 34 metabolites, including 19 phase I and 15 phase II metabolites, were identified. Similar metabolite profiles were observed among species, and demethylation, hydroxylation, carboxylic acid formation, and glucuronidation were proposed as the major metabolic routes. Significant interspecies differences were observed in the metabolic stability studies of TJ0711. Furthermore, gender differences were significant in mice, rats, and dogs, but were negligible in humans. The valuable information provided in this work will be useful in planning and interpreting further pharmacokinetic, in vivo metabolism and toxicological studies of this novel β-blocker. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Kazarian, Artaches A; Nesterenko, Pavel N; Soisungnoen, Phimpha; Burakham, Rodjana; Srijaranai, Supalax; Paull, Brett
2014-08-01
Liquid chromatographic assays were developed using a mixed-mode column coupled in sequence with a hydrophilic interaction liquid chromatography column to allow the simultaneous comprehensive analysis of inorganic/organic anions and cations, active pharmaceutical ingredients, and excipients (carbohydrates). The approach utilized dual sample injection and valve-mediated column switching and was based upon a single high-performance liquid chromatography gradient pump. The separation consisted of three distinct sequential separation mechanisms, namely, (i) ion-exchange, (ii) mixed-mode interactions under an applied dual gradient (reversed-phase/ion-exchange), and (iii) hydrophilic interaction chromatography. Upon first injection, the Scherzo SS C18 column (Imtakt) provided resolution of inorganic anions and cations under isocratic conditions, followed by a dual organic/salt gradient to elute active pharmaceutical ingredients and their respective organic counterions and potential degradants. At the top of the mixed-mode gradient (high acetonitrile content), the mobile phase flow was switched to a preconditioned hydrophilic interaction liquid chromatography column, and the standard/sample was reinjected for the separation of hydrophilic carbohydrates, some of which are commonly known excipients in drug formulations. The approach afforded reproducible separation and resolution of up to 23 chemically diverse solutes in a single run. The method was applied to investigate the composition of commercial cough syrups (Robitussin®), allowing resolution and determination of inorganic ions, active pharmaceutical ingredients, excipients, and numerous well-resolved unknown peaks. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Metz, Thomas O.; Zhang, Qibin; Page, Jason S.; Shen, Yufeng; Callister, Stephen J.; Jacobs, Jon M.; Smith, Richard D.
2008-01-01
SUMMARY The future utility of liquid chromatography-mass spectrometry (LC-MS) in metabolic profiling and metabolomic studies for biomarker discover will be discussed, beginning with a brief description of the evolution of metabolomics and the utilization of the three most popular analytical platforms in such studies: NMR, GC-MS, and LC-MS. Emphasis is placed on recent developments in high-efficiency LC separations, sensitive electrospray ionization approaches, and the benefits to incorporating both in LC-MS-based approaches. The advantages and disadvantages of various quantitative approaches are reviewed, followed by the current LC-MS-based tools available for candidate biomarker characterization and identification. Finally, a brief prediction on the future path of LC-MS-based methods in metabolic profiling and metabolomic studies is given. PMID:19177179
Zeeb, Mohsen; Farahani, Hadi; Papan, Mohammad Kazem
2016-06-01
An efficient analytical method called ionic-liquid-based ultrasound-assisted in situ solvent formation microextraction followed by high-performance liquid chromatography was developed for the determination of atenolol in human plasma. A hydrophobic ionic liquid (1-butyl-3-methylimidazolium hexafluorophosphate) was formed by the addition of a hydrophilic ionic liquid (1-butyl-3-methylimidazolium tetrafluoroborate) to a sample solution containing an ion-pairing agent during microextraction. The analyte was extracted into the ionic liquid phase while the microextraction solvent was dispersed throughout the sample by utilizing ultrasound. The sample was then centrifuged, and the extracting phase retracted into the microsyringe and injected to liquid chromatography. After optimization, the calibration curve showed linearity in the range of 2-750 ng/mL with the regression coefficient corresponding to 0.998. The limits of detection (S/N = 3) and quantification (S/N = 10) were 0.5 and 2 ng/mL, respectively. A reasonable relative recovery range of 90-96.7% and satisfactory intra-assay (4.8-5.1%, n = 6) and interassay (5.0-5.6%, n = 9) precision along with a substantial sample clean-up demonstrated good performance of the procedure. It was applied for the determination of atenolol in human plasma after oral administration and some pharmacokinetic data were obtained. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Liquid Crystals in Chromatography
NASA Astrophysics Data System (ADS)
Witkiewicz, Zygfryd
The following sections are included: * INTRODUCTION * LIQUID CRYSTALS SUITABLE FOR GAS CHROMATOGRAPHY * Monomeric Liquid Crystal Stationary Phases * Polymeric Liquid Crystal Stationary Phases * Polymeric Liquid Crystal Stationary Phases * Conventional Analytical Columns * Capillary Columns * FACTORS AFFECTING THE CHROMATOGRAPHIC SEPARATIONS ON LIQUID CRYSTAL STATIONARY PHASES * Kind of Mesophase of the Liquid Crystal * Molecular Structure of the Liquid Crystals and of the Chromatographed Substances * Substrate on which the Liquid Crystal is Deposited * ANALYTICAL APPLICATIONS OF LIQUID CRYSTAL STATIONARY PHASES IN GAS CHROMATOGRAPHY * Separation of Isomers of Benzene and Naphthalene Derivatives * Separation of Alkane and Alkene Isomers * Separation of Mixtures of Benzene and Aliphatic Hydrocarbon Derivatives Containing Heteroatoms * Separation of Polynuclear Hydrocarbons * INVESTIGATION OF THE PROPERTIES OF LIQUID CRYSTALS BY GAS CHROMATOGRAPHY * APPLICATION OF LIQUID CRYSTALS IN LIQUID CHROMATOGRAPHY * Column Chromatography * Thin-Layer Chromatography * APPLICATION OF LIQUID CRYSTAL STATIONARY PHASES IN SUPERCRITICAL FLUID CHROMATOGRAPHY * FINAL REMARKS * References
Mass spectrometric based approaches in urine metabolomics and biomarker discovery.
Khamis, Mona M; Adamko, Darryl J; El-Aneed, Anas
2017-03-01
Urine metabolomics has recently emerged as a prominent field for the discovery of non-invasive biomarkers that can detect subtle metabolic discrepancies in response to a specific disease or therapeutic intervention. Urine, compared to other biofluids, is characterized by its ease of collection, richness in metabolites and its ability to reflect imbalances of all biochemical pathways within the body. Following urine collection for metabolomic analysis, samples must be immediately frozen to quench any biogenic and/or non-biogenic chemical reactions. According to the aim of the experiment; sample preparation can vary from simple procedures such as filtration to more specific extraction protocols such as liquid-liquid extraction. Due to the lack of comprehensive studies on urine metabolome stability, higher storage temperatures (i.e. 4°C) and repetitive freeze-thaw cycles should be avoided. To date, among all analytical techniques, mass spectrometry (MS) provides the best sensitivity, selectivity and identification capabilities to analyze the majority of the metabolite composition in the urine. Combined with the qualitative and quantitative capabilities of MS, and due to the continuous improvements in its related technologies (i.e. ultra high-performance liquid chromatography [UPLC] and hydrophilic interaction liquid chromatography [HILIC]), liquid chromatography (LC)-MS is unequivocally the most utilized and the most informative analytical tool employed in urine metabolomics. Furthermore, differential isotope tagging techniques has provided a solution to ion suppression from urine matrix thus allowing for quantitative analysis. In addition to LC-MS, other MS-based technologies have been utilized in urine metabolomics. These include direct injection (infusion)-MS, capillary electrophoresis-MS and gas chromatography-MS. In this article, the current progresses of different MS-based techniques in exploring the urine metabolome as well as the recent findings in providing potentially diagnostic urinary biomarkers are discussed. © 2015 Wiley Periodicals, Inc. Mass Spec Rev 36:115-134, 2017. © 2015 Wiley Periodicals, Inc.
Kertesz, Vilmos; Van Berkel, Gary J
2010-07-15
In this work, a commercially available autosampler was adapted to perform direct liquid microjunction (LMJ) surface sampling followed by a high-pressure liquid chromatography (HPLC) separation of the extract components and detection with electrospray ionization mass spectrometry (ESI-MS). To illustrate the utility of coupling a separation with this direct liquid extraction based surface sampling approach, four different organs (brain, lung, kidney, and liver) from whole-body thin tissue sections of propranolol dosed and control mice were examined. The parent drug was observed in the chromatograms of the surface sampling extracts from all the organs of the dosed mouse examined. In addition, two isomeric phase II metabolites of propranolol (an aliphatic and an aromatic hydroxypropranolol glucuronide) were observed in the chromatograms of the extracts from lung, kidney, and liver. Confirming the presence of one or the other or both of these glucuronides in the extract from the various organs was not possible without the separation. These drug and metabolite data obtained using the LMJ surface sampling/HPLC-MS method and the results achieved by analyzing similar samples by conventional extraction of the tissues and subsequent HPLC-MS analysis were consistent. The ability to directly and efficiently sample from thin tissue sections via a liquid extraction and then perform a subsequent liquid phase separation increases the utility of this liquid extraction surface sampling approach.
Quantitative characterization of the aqueous fraction from hydrothermal liquefaction of algae
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maddi, Balakrishna; Panisko, Ellen; Wietsma, Thomas
Aqueous streams generated from hydrothermal liquefaction contain approximately 30% of the total carbon present from the algal feed. Hence, this aqueous carbon must be utilized to produce liquid fuels and/or specialty chemicals for economic sustainability of hydrothermal liquefaction on industrial scale. In this study, aqueous fractions produced from the hydrothermal liquefaction of fresh water and saline water algal cultures were analyzed using a wide variety of analytical instruments to determine their compositional characteristics. This study will also inform researchers designing catalysts for down-stream processing such as high-pressure catalytic conversion of organics in aqueous phase, catalytic hydrothermal gasification, and biological conversions.more » Organic chemical compounds present in all eight aqueous fractions were identified using two-dimensional gas chromatography equipped with time-of-flight mass spectrometry. Identified compounds include organic acids, nitrogen compounds and aldehydes/ketones. Conventional gas chromatography and liquid chromatography methods were utilized to quantify the identified compounds. Inorganic species in the aqueous stream of hydrothermal liquefaction of algae were identified using ion chromatography and inductively coupled plasma optical emission spectrometer. The concentrations of organic chemical compounds and inorganic species are reported. The amount quantified carbon ranged from 45 to 72 % of total carbon in the aqueous fractions.« less
Recent applications of hydrophilic interaction liquid chromatography in pharmaceutical analysis.
Zhang, Qian; Yang, Feng-Qing; Ge, Liya; Hu, Yuan-Jia; Xia, Zhi-Ning
2017-01-01
Hydrophilic interaction liquid chromatography, an alternative liquid chromatography mode, is of particular interest in separating hydrophilic and polar ionic compounds. Compared with traditional liquid chromatography techniques, hydrophilic interaction liquid chromatography offers specific advantages mainly including: (1) relatively green and water-soluble mobile phase composition, which enhances the solubility of hydrophilic and polar ionic compounds; (2) no need for ion-pairing reagents and high content of organic solvent, which benefits mass spectrometry detection; (3) high orthogonality to reverse-phase liquid chromatography, well adapted to two-dimensional liquid chromatography for complicated samples. Therefore, hydrophilic interaction liquid chromatography has been rapidly developed in many areas over the past decades. This review summarizes the recent progress (from 2012 to July 2016) of hydrophilic interaction liquid chromatography in pharmaceutical analysis, with the focus on detecting chemical drugs in various matrices, charactering active compounds of natural products and assessing biotherapeutics through typical structure unit. Moreover, the retention mechanism and behavior of analytes in hydrophilic interaction liquid chromatography as well as some novel hydrophilic interaction liquid chromatography columns used for pharmaceutical analysis are also described. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Ono, Toshirou; Usami, Atsushi; Nakaya, Satoshi; Shinpuku, Hideto; Yonejima, Yasunori; Ikeda, Atsushi; Miyazawa, Mitsuo
2015-01-01
Volatile oils obtained from both the liquid medium after incubation (MAI) and liquid medium before incubation (MBI) during the cultivation process of Lactobacillus brevis were isolated by hydrodistillation (HD) and analyzed to determine the utility of the liquid waste. The composition of the volatile oils was analyzed by capillary gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS). In total, 55 and 36 compounds were detected in the volatile oils from MAI (MAI oil) and MBI (MBI oil), respectively. The principle components of MAI oil were N-containing compounds, including 2,3-dimethylpyrazine (16, 37.1 %), methylpyrazine (4, 17.1 %). The important aroma-active compounds in the oils were detected by GC-Olfactometry (GC-O), and their intensity of aroma were measured by aroma extract dilution analysis (AEDA). Expressly, pyrazine compounds were determined as key aroma components; in particular, 2,5-dimethylpyrazine and 2,3-dimethylpyrazine were the most primary aroma-active compound in MAI oil. These results imply that the waste medium after incubation of L. brevis may be utilized as a source of volatile oils.
Razavi, Morteza; Frick, Lauren E; LaMarr, William A; Pope, Matthew E; Miller, Christine A; Anderson, N Leigh; Pearson, Terry W
2012-12-07
We investigated the utility of an SPE-MS/MS platform in combination with a modified SISCAPA workflow for chromatography-free MRM analysis of proteotypic peptides in digested human plasma. This combination of SISCAPA and SPE-MS/MS technology allows sensitive, MRM-based quantification of peptides from plasma digests with a sample cycle time of ∼7 s, a 300-fold improvement over typical MRM analyses with analysis times of 30-40 min that use liquid chromatography upstream of MS. The optimized system includes capture and enrichment to near purity of target proteotypic peptides using rigorously selected, high affinity, antipeptide monoclonal antibodies and reduction of background peptides using a novel treatment of magnetic bead immunoadsorbents. Using this method, we have successfully quantitated LPS-binding protein and mesothelin (concentrations of ∼5000 ng/mL and ∼10 ng/mL, respectively) in human plasma. The method eliminates the need for upstream liquid-chromatography and can be multiplexed, thus facilitating quantitative analysis of proteins, including biomarkers, in large sample sets. The method is ideal for high-throughput biomarker validation after affinity enrichment and has the potential for applications in clinical laboratories.
Liu, Cui-Ting; Zhang, Min; Yan, Ping; Liu, Hai-Chan; Liu, Xing-Yun; Zhan, Ruo-Ting
2016-01-01
Zhengtian pills (ZTPs) are traditional Chinese medicine (TCM) which have been commonly used to treat headaches. Volatile components of ZTPs extracted by ethyl acetate with an ultrasonic method were analyzed by gas chromatography mass spectrometry (GC-MS). Twenty-two components were identified, accounting for 78.884% of the total components of volatile oil. The three main volatile components including protocatechuic acid, ferulic acid, and ligustilide were simultaneously determined using ultra-high performance liquid chromatography coupled with diode array detection (UHPLC-DAD). Baseline separation was achieved on an XB-C18 column with linear gradient elution of methanol-0.2% acetic acid aqueous solution. The UHPLC-DAD method provided good linearity (R (2) ≥ 0.9992), precision (RSD < 3%), accuracy (100.68-102.69%), and robustness. The UHPLC-DAD/GC-MS method was successfully utilized to analyze volatile components, protocatechuic acid, ferulic acid, and ligustilide, in 13 batches of ZTPs, which is suitable for discrimination and quality assessment of ZTPs.
Sun, Meng; Ren, Jing; Du, Hui; Zhang, Yanmin; Zhang, Jie; Wang, Sicen; He, Langchong
2010-10-15
We have developed an online analytical method that combines A431 cell membrane chromatography (A431/CMC) with high performance liquid chromatography and mass spectrometry (LC/MS) for identifying active components from Radix Caulophylli acting on human EGFR. Retention fractions on A431/CMC model were captured onto an enrichment column and the components were directly analyzed by combining a 10-port column switcher with an LC/MS system for separation and preliminary identification. Using Sorafenib tosylate as a positive control, taspine and caulophine from Radix Caulophylli were identified as the active molecules which could act on the EGFR. This A431/CMC-online-LC/MS method can be applied for screening active components acting on EGFR from traditional Chinese medicines exemplified by Radix Caulophylli and will be of great utility in drug discovery using natural medicinal herbs as a source of novel compounds. Copyright © 2010 Elsevier B.V. All rights reserved.
Bioreactor Steroid Production and Analysis of Date Palm Embryogenic Callus.
El-Sharabasy, Sherif; El-Dawayati, Maiada
2017-01-01
Several compounds and families of compounds of date palm secondary metabolites have been investigated. The analysis of date palm tissue has shown the abundance of secondary metabolites including phytosterols, e.g., steroids, an important group of pharmaceutical compounds. Biotechnology offers the opportunity to utilize cells, tissues, and organs grown in vitro and manipulated to obtain desired compounds. This chapter presents a protocol for the production, determination, and identification of steroids in date palm callus tissue. The addition of 0.01 mg/L pyruvic acid as a precursor to MS liquid culture medium enhances steroid production. In addition, the chapter describes the sterol analytical techniques based on gas-liquid chromatography and gas chromatography-mass spectrometry.
Carr, John E; Kwok, Kaho; Webster, Gregory K; Carnahan, Jon W
2006-01-23
Atomic spectrometry, specifically inductively coupled plasma atomic emission spectrometry (ICP-AES) and mass spectrometry (ICP-MS) show promise for heteroatom-based detection of pharmaceutical compounds. The combination of ultrasonic nebulization (USN) with membrane desolvation (MD) greatly enhances detection limits with these approaches. Because pharmaceutical analyses often incorporate liquid chromatography, the study herein was performed to examine the effects of solvent composition on the analytical behaviors of these approaches. The target analyte was phosphorus, introduced as phosphomycin. AES response was examined at the 253.7 nm atom line and mass 31 ions were monitored for the MS experiments. With pure aqueous solutions, detection limits of 5 ppb (0.5 ng in 0.1 mL injection volumes) were obtained with ICP-MS. The ICP-AES detection limit was 150 ppb. Solvent compositions were varied from 0 to 80% organic (acetonitrile and methanol) with nine buffers at concentrations typically used in liquid chromatography. In general, solvents and buffers had statistically significant, albeit small, effects on ICP-AES sensitivities. A few exceptions occurred in cases where typical liquid chromatography buffer concentrations produced higher mass loadings on the plasma. Indications are that isocratic separations can be reliably performed. Within reasonable accuracy tolerances, it appears that gradient chromatography can be performed without the need for signal response normalization. Organic solvent and buffer effects were more significant with ICP-MS. Sensitivities varied significantly with different buffers and organic solvent content. In these cases, gradient chromatography will require careful analytical calibration as solvent and buffer content is varied. However, for most buffer and solvent combinations, signal and detection limits are only moderately affected. Isocratic separations and detection are feasible.
DOT National Transportation Integrated Search
1977-05-04
Technology was developed for determining delta sup 9-tetrahydrocannabinol (I) and its major metabolite 11-nor-delta sup 9-tetrahydrocannabinol-9-carboxylic acid (II) in human blood plasma utilizing high pressure liquid chromatography (hplc)-ultraviol...
Optimizing separations in online comprehensive two‐dimensional liquid chromatography
Gargano, Andrea F.G.; Schoenmakers, Peter J.
2017-01-01
Abstract Online comprehensive two‐dimensional liquid chromatography has become an attractive option for the analysis of complex nonvolatile samples found in various fields (e.g. environmental studies, food, life, and polymer sciences). Two‐dimensional liquid chromatography complements the highly popular hyphenated systems that combine liquid chromatography with mass spectrometry. Two‐dimensional liquid chromatography is also applied to the analysis of samples that are not compatible with mass spectrometry (e.g. high‐molecular‐weight polymers), providing important information on the distribution of the sample components along chemical dimensions (molecular weight, charge, lipophilicity, stereochemistry, etc.). Also, in comparison with conventional one‐dimensional liquid chromatography, two‐dimensional liquid chromatography provides a greater separation power (peak capacity). Because of the additional selectivity and higher peak capacity, the combination of two‐dimensional liquid chromatography with mass spectrometry allows for simpler mixtures of compounds to be introduced in the ion source at any given time, improving quantitative analysis by reducing matrix effects. In this review, we summarize the rationale and principles of two‐dimensional liquid chromatography experiments, describe advantages and disadvantages of combining different selectivities and discuss strategies to improve the quality of two‐dimensional liquid chromatography separations. PMID:29027363
Dispersion polymerization of L-lactide utilizing ionic liquids as reaction medium
NASA Astrophysics Data System (ADS)
Fahmiati, Sri; Minami, Hideto; Haryono, Agus; Adilina, Indri B.
2017-11-01
Dispersion polymerization of L-lactide was proceeded in various ionic liquids. Ionic liquids as 1-Hexyl-3-methylimidazolium bis (trifluormethylsulfonyl) imide, [HMIM] [TFSI], 1-Butyl-3-methylimidazolium bis (trifluoromethylsulfonyl) imide, [BMP] [TFSI], and N,N,N-Trimethyl-N-Propylammonium Bis (trifloromethanesulfonyl) imide, [TMPA] [TFSI], were employed as reaction medium that dissolved both of lactide and stabilizer (polyvinylprrolidone). Sn-supported on bentonite was used as a ring opening catalyst of L-lactide. Gel Permeation Chromatography result showed that poly-(L-lactic acid) were formed in ionic liquids [HMIM] [TFSI] and [BMP] [TFSI] with molecular weight as 19390 and 20844, respectively.
Ono, Toshirou; Yonejima, Yasunori; Ikeda, Atsushi; Kashima, Yusei; Nakaya, Satoshi; Miyazawa, Mitsuo
2014-01-01
Volatile oils obtained from both the liquid medium after incubation (MAI) and liquid medium before incubation (MBI) in the cultivation process of Lactobacillus acidophilus were isolated by hydrodistillation (HD) and analyzed to investigate the utility of the liquid waste. The composition of the volatile oils was analyzed by capillary gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS). In total, 46 and 19 compounds were detected in the volatile oils from MAI (MAI oil) and MBI (MBI oil), respectively. The principle components of MAI oil were fatty acids, including pentanoic acid (12.75%), heptanoic acid (14.05%), and nonanoic acid (14.04%). The important aroma-active compounds in the oils were detected by GC-MS/Olfactometry (GC-O), and their intensity of aroma were measured by aroma extraction dilution analysis (AEDA). Pyrazines were determined as key aroma components; in particular, 2-ethyl-5-methylpyrazine was the most primary aroma-active compound in MAI oil. In addition, as the characteristic aroma-active compounds, 3-(methylthio)-propanal, trimethylpyrazine, and pentanoic acid were also detected in MAI oil. These results imply that the waste medium after incubation of L. acidophilus may be utilized as a source of volatile oils.
Optimizing separations in online comprehensive two-dimensional liquid chromatography.
Pirok, Bob W J; Gargano, Andrea F G; Schoenmakers, Peter J
2018-01-01
Online comprehensive two-dimensional liquid chromatography has become an attractive option for the analysis of complex nonvolatile samples found in various fields (e.g. environmental studies, food, life, and polymer sciences). Two-dimensional liquid chromatography complements the highly popular hyphenated systems that combine liquid chromatography with mass spectrometry. Two-dimensional liquid chromatography is also applied to the analysis of samples that are not compatible with mass spectrometry (e.g. high-molecular-weight polymers), providing important information on the distribution of the sample components along chemical dimensions (molecular weight, charge, lipophilicity, stereochemistry, etc.). Also, in comparison with conventional one-dimensional liquid chromatography, two-dimensional liquid chromatography provides a greater separation power (peak capacity). Because of the additional selectivity and higher peak capacity, the combination of two-dimensional liquid chromatography with mass spectrometry allows for simpler mixtures of compounds to be introduced in the ion source at any given time, improving quantitative analysis by reducing matrix effects. In this review, we summarize the rationale and principles of two-dimensional liquid chromatography experiments, describe advantages and disadvantages of combining different selectivities and discuss strategies to improve the quality of two-dimensional liquid chromatography separations. © 2017 The Authors. Journal of Separation Science published by WILEY-VCH Verlag GmbH & Co. KGaA.
Carol-Visser, Jeroen; van der Schans, Marcel; Fidder, Alex; Hulst, Albert G; van Baar, Ben L M; Irth, Hubertus; Noort, Daan
2008-07-01
Rapid monitoring and retrospective verification are key issues in protection against and non-proliferation of chemical warfare agents (CWA). Such monitoring and verification are adequately accomplished by the analysis of persistent protein adducts of these agents. Liquid chromatography-mass spectrometry (LC-MS) is the tool of choice in the analysis of such protein adducts, but the overall experimental procedure is quite elaborate. Therefore, an automated on-line pepsin digestion-LC-MS configuration has been developed for the rapid determination of CWA protein adducts. The utility of this configuration is demonstrated by the analysis of specific adducts of sarin and sulfur mustard to human butyryl cholinesterase and human serum albumin, respectively.
Han, Zheng; Zheng, Yunliang; Chen, Na; Luan, Lianjun; Zhou, Changxin; Gan, Lishe; Wu, Yongjiang
2008-11-28
A new separation and quantification method using liquid chromatography under ultra-high-pressure in combination with tandem mass spectrometry (MS/MS) was developed for simultaneous determination of four alkaloids in Lindera aggregata. The analysis was performed on an Acquity UPLC BEH C(18) column (50mmx2.1mm, 1.7microm particle size; Waters, Milford, MA, USA) utilizing a gradient elution profile and a mobile phase consisting of (A) water containing 10mM ammonium acetate adjusted to pH 3 with acetic acid and (B) acetonitrile. An electrospray ionization (ESI)-tandem interface in the positive mode was employed prior to mass spectrometric detection. The calibration curve was linear over the range of 17.1-856ng for boldine, 42.4-2652ng for norboldine, 6.1-304ng for reticuline and 0.5-50ng for linderegatine, respectively. The average recoveries ranged from 99.2 to 101.4% with RSDs< or =2.7%. Then, four L. aggregata samples from different batches were analyzed using the established method. The results indicated that ultra-high-pressure liquid chromatography-tandem mass spectrometry provided improved chromatographic parameters resulting in significantly increased sample throughput including lower solvent consumption and lower limits of quantitation (LOQs) for most of target analytes compared to previous method employing conventional high-performance liquid chromatography (HPLC) separation. So, the established method was validated, sensitive and reliable for the determination of four alkaloids in L. aggregata.
Venkatramani, C J; Al-Sayah, Mohammad; Li, Guannan; Goel, Meenakshi; Girotti, James; Zang, Lisa; Wigman, Larry; Yehl, Peter; Chetwyn, Nik
2016-02-01
A new interface was designed to enable the coupling of reversed phase liquid chromatography (RPLC) and supercritical fluid chromatography (SFC). This online two-dimensional chromatographic system utilizing RPLC in the first dimension and SFC in the second was developed to achieve simultaneous achiral and chiral analysis of pharmaceutical compounds. The interface consists of an eight-port, dual-position switching valve with small volume C-18 trapping columns. The peaks of interest eluting from the first RPLC dimension column were effectively focused as sharp concentration pulses on small volume C-18 trapping column/s and then injected onto the second dimension SFC column. The first dimension RPLC separation provides the achiral purity result, and the second dimension SFC separation provides the chiral purity result (enantiomeric excess). The results are quantitative enabling simultaneous achiral, chiral analysis of compounds. The interface design and proof of concept demonstration are presented. Additionally, comparative studies to conventional SFC and case studies of the applications of 2D LC-SFC in pharmaceutical analysis is presented. Copyright © 2015 Elsevier B.V. All rights reserved.
Managing Fuel Quality in the Department of Defense.
1987-06-01
effects on deposit kinetics. * New techniques utilizing mass spectroscopy and supercritical liquid chromatography are helping to understand the mechanism of...with complexity factors of 3 for each, but also Fluid Coking and Delayed Coking, with factors of 5 apiece. The corresponding category in Table D-l
Kabytaev, Kuanysh; Durairaj, Anita; Shin, Dmitriy; Rohlfing, Curt L; Connolly, Shawn; Little, Randie R; Stoyanov, Alexander V
2016-02-01
A liquid chromatography with mass spectrometry on-line platform that includes the orthogonal techniques of ion exchange and reversed phase chromatography is applied for C-peptide analysis. Additional improvement is achieved by the subsequent application of cation- and anion-exchange purification steps that allow for isolating components that have their isoelectric points in a narrow pH range before final reversed-phase mass spectrometry analysis. The utility of this approach for isolating fractions in the desired "pI window" for profiling complex mixtures is discussed. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Sandra, Koen; Pereira, Alberto Dos Santos; Vanhoenacker, Gerd; David, Frank; Sandra, Pat
2010-06-18
A lipidomics strategy, combining high resolution reversed-phase liquid chromatography (RPLC) with high resolution quadrupole time-of-flight mass spectrometry (QqTOF), is described. The method has carefully been assessed in both a qualitative and a quantitative fashion utilizing human blood plasma. The inherent low technical variability associated with the lipidomics method allows to measure 65% of the features with an intensity RSD value below 10%. Blood plasma lipid spike-in experiments demonstrate that relative concentration differences smaller than 25% can readily be revealed by means of a t-test. Utilizing an advanced identification strategy, it is shown that the detected features mainly originate from (lyso-)phospholipids, sphingolipids, mono-, di- and triacylglycerols and cholesterol esters. The high resolution offered by the up-front RPLC step further allows to discriminate various isomeric species associated with the different lipid classes. The added value of utilizing a Jetstream electrospray ionization (ESI) source over a regular ESI source in lipidomics is for the first time demonstrated. In addition, the application of ultra high performance LC (UHPLC) up to 1200bar to extend the peak capacity or increase productivity is discussed. Copyright (c) 2010 Elsevier B.V. All rights reserved.
Effect of Genetic Database Comprehensiveness on Fractional Proteomics of Escherichia coli O157:H7
2014-01-01
proteins would be observed in the extracellular fraction. 15. SUBJECT TERMS Escherichia coli O157:H7 Liquid chromatography Mass spectrometry...Preparation ...............1 2.2 Liquid Chromatography /Mass Spectrometry Sample Preparation ....................2 2.3 Liquid Chromatography /Mass... Chromatography /Mass Spectrometry Sample Preparation. Samples were prepared for liquid chromatography tandem mass spectrometry (LC-MS/MS) in a similar
Selvaggini, Roberto; Servili, Maurizio; Urbani, Stefania; Esposto, Sonia; Taticchi, Agnese; Montedoro, GianFrancesco
2006-04-19
Hydrophilic phenols are the most abundant natural antioxidants of virgin olive oil (VOO), in which tocopherols and carotenes are also present. The prevalent classes of hydrophilic phenols found in VOO are phenyl alcohols, phenolic acids, secoiridoids such as the dialdehydic form of decarboxymethyl elenolic acid linked to (3,4-dihydroxyphenyl)ethanol or (p-hydroxypheny1)ethanol (3,4-DHPEA-EDA or p-HPEA-EDA) and an isomer of the oleuropein aglycon (3,4-DHPEA-EA), lignans such as (+)-1-acetoxypinoresinol and (+)-pinoresinol, and flavonoids. A new method for the analysis of VOO hydrophilic phenols by direct injection in high-performance liquid chromatography (HPLC) with the use of a fluorescence detector (FLD) has been proposed and compared with the traditional liquid-liquid extraction technique followed by the HPLC analysis utilizing a diode array detector (DAD) and a FLD. Results show that the most important classes of phenolic compounds occurring in VOO can be evaluated using HPLC direct injection. The efficiency of the new method, as compared to the liquid-liquid extraction, was higher to quantify phenyl alcohols, lignans, and 3,4-DHPEA-EA and lower for the evaluation of 3,4-DHPEA-EDA and p-HPEA-EDA.
Zheng, Longfang; Zhao, Xian-En; Zhu, Shuyun; Tao, Yanduo; Ji, Wenhua; Geng, Yanling; Wang, Xiao; Chen, Guang; You, Jinmao
2017-06-01
In this work, for the first time, a new hyphenated technique of stable isotope-labeling derivatization-ultrasound-assisted dispersive liquid-liquid microextraction has been developed for the simultaneous determination of monoamine neurotransmitters (MANTs) and their biosynthesis precursors and metabolites. The developed method was based on ultra high performance liquid chromatography tandem mass spectrometry detection using multiple-reaction monitoring mode. A pair of mass spectrometry sensitizing reagents, d 0 -10-methyl-acridone-2-sulfonyl chloride and d 3 -10-methyl-acridone-2-sulfonyl chloride, as stable isotope probes was utilized to facilely label neurotransmitters, respectively. The heavy labeled MANTs standards were prepared and used as internal standards for quantification to minimize the matrix effects in mass spectrometry analysis. Low toxic bromobenzene (extractant) and acetonitrile (dispersant) were utilized in microextraction procedure. Under the optimized conditions, good linearity was observed with the limits of detection (S/N>3) and limits of quantification (S/N>10) in the range of 0.002-0.010 and 0.015-0.040nmol/L, respectively. Meanwhile, it also brought acceptable precision (4.2-8.8%, peak area RSDs %) and accuracy (recovery, 96.9-104.1%) results. This method was successfully applied to the simultaneous determination of monoamine neurotransmitters and their biosynthesis precursors and metabolites in rat brain microdialysates of Parkinson's disease and normal rats. This provided a new method for the neurotransmitters related studies in the future. Copyright © 2017 Elsevier B.V. All rights reserved.
USDA-ARS?s Scientific Manuscript database
Capillary electrophoresis (CE) and reversed-phase high performance liquid chromatography (RP-HPLC) analysis were utilized to detect differences in the sarcoplasmic protein profiles of beef strip loins subjected to aging and hydrodynamic pressure processing (HDP) treatments. At 48 h postmortem, stri...
A rapid and sensitive method has been developed for the analysis of 48 human prescription active pharmaceutical ingredients (APIs) and 6 metabolites of interest, utilizing selective solid-phase extraction (SPE) and ultra performance liquid chromatography in combination with tripl...
Valeja, Santosh G; Xiu, Lichen; Gregorich, Zachery R; Guner, Huseyin; Jin, Song; Ge, Ying
2015-01-01
To address the complexity of the proteome in mass spectrometry (MS)-based top-down proteomics, multidimensional liquid chromatography (MDLC) strategies that can effectively separate proteins with high resolution and automation are highly desirable. Although various MDLC methods that can effectively separate peptides from protein digests exist, very few MDLC strategies, primarily consisting of 2DLC, are available for intact protein separation, which is insufficient to address the complexity of the proteome. We recently demonstrated that hydrophobic interaction chromatography (HIC) utilizing a MS-compatible salt can provide high resolution separation of intact proteins for top-down proteomics. Herein, we have developed a novel 3DLC strategy by coupling HIC with ion exchange chromatography (IEC) and reverse phase chromatography (RPC) for intact protein separation. We demonstrated that a 3D (IEC-HIC-RPC) approach greatly outperformed the conventional 2D IEC-RPC approach. For the same IEC fraction (out of 35 fractions) from a crude HEK 293 cell lysate, a total of 640 proteins were identified in the 3D approach (corresponding to 201 nonredundant proteins) as compared to 47 in the 2D approach, whereas simply prolonging the gradients in RPC in the 2D approach only led to minimal improvement in protein separation and identifications. Therefore, this novel 3DLC method has great potential for effective separation of intact proteins to achieve deep proteome coverage in top-down proteomics.
21 CFR 862.2260 - High pressure liquid chromatography system for clinical use.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false High pressure liquid chromatography system for... Clinical Laboratory Instruments § 862.2260 High pressure liquid chromatography system for clinical use. (a) Identification. A high pressure liquid chromatography system for clinical use is a device intended to separate...
21 CFR 862.2260 - High pressure liquid chromatography system for clinical use.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false High pressure liquid chromatography system for... Clinical Laboratory Instruments § 862.2260 High pressure liquid chromatography system for clinical use. (a) Identification. A high pressure liquid chromatography system for clinical use is a device intended to separate...
21 CFR 862.2260 - High pressure liquid chromatography system for clinical use.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false High pressure liquid chromatography system for... Clinical Laboratory Instruments § 862.2260 High pressure liquid chromatography system for clinical use. (a) Identification. A high pressure liquid chromatography system for clinical use is a device intended to separate...
21 CFR 862.2260 - High pressure liquid chromatography system for clinical use.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false High pressure liquid chromatography system for... Clinical Laboratory Instruments § 862.2260 High pressure liquid chromatography system for clinical use. (a) Identification. A high pressure liquid chromatography system for clinical use is a device intended to separate...
21 CFR 862.2260 - High pressure liquid chromatography system for clinical use.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false High pressure liquid chromatography system for... Clinical Laboratory Instruments § 862.2260 High pressure liquid chromatography system for clinical use. (a) Identification. A high pressure liquid chromatography system for clinical use is a device intended to separate...
Wu, Hongwei; Chen, Meilan; Fan, Yunchang; Elsebaei, Fawzi; Zhu, Yan
2012-01-15
A novel ionic liquid-based pressurized liquid extraction (IL-PLE) procedure coupled with high performance liquid chromatography (HPLC) tandem chemiluminescence (CL) detection capable of quantifying trace amounts of rutin and quercetin in four Chinese medicine plants including Flos sophorae Immaturus, Crateagus pinnatifida Bunge, Hypericum japonicum Thunb and Folium Mori was described in this paper. To avoid environmental pollution and toxicity to the operators, ionic liquids (ILs), 1-alkyl-3-methylimidazolium chloride ([C(n)mim][Cl]) aqueous solutions were used in the PLE procedure as extractants replacing traditional organic solvents. In addition, chemiluminescence detection was utilized for its minimal interference from endogenous components of complex matrix. Parameters affecting extraction and analysis were carefully optimized. Compared with the conventional ultrasonic-assisted extraction (UAE) and heat-reflux extraction (HRE), the optimized method achieved the highest extraction efficiency in the shortest extraction time with the least solvent consumption. The applicability of the proposed method to real sample was confirmed. Under the optimized conditions, good reproducibility of extraction performance was obtained and good linearity was observed with correlation coefficients (r) between 0.9997 and 0.9999. The detection limits of rutin and quercetin (LOD, S/N=3) were 1.1×10(-2)mg/L and 3.8×10(-3)mg/L, respectively. The average recoveries of rutin and quercetin for real samples were 93.7-105% with relative standard deviation (RSD) lower than 5.7%. To the best of our knowledge, this paper is the first contribution to utilize a combination of IL-PLE with chemiluminescence detection. And the experimental results indicated that the proposed method shows a promising prospect in extraction and determination of rutin and quercetin in medicinal plants. Copyright © 2011 Elsevier B.V. All rights reserved.
Guan, Zhibo; Wang, Miao; Cai, Yi; Yang, Hongmei; Zhao, Min; Zhao, Chunjie
2018-06-01
Sijunzi decoction, a renowned Chinese prescription has long been utilized to treat gastrointestinal problems. In the context of this research work, the use of Ultra high performance liquid chromatography combined with Fourier transform ion cyclotron resonance mass spectrometry was made to separate and characterize the components of Sijunzi decoction. The performance of Liquid chromatography was carried out on a C8 column (150 mm × 2.1 mm, 1.8 μm); moreover, the mobile phase were consisted of 0.2% formic acid (A) and acetonitrile (B). In accordance with the findings, characterization of 120 chemical compounds was performed by liquid chromatography with mass spectrometry. The key constituents among them included ginsenosides (in Radix Ginseng), 16 triterpene carboxylic acids (in Poria), sesquiterpenes (in Rhizoma Atractylodis Macrocephalae), triterpenesaponins (in Glycyrrhizae Radix et Rhizoma Praeparata Cum Melle) as well as flavonoids (in Glycyrrhizae Radix et Rhizoma Praeparata Cum Melle) in Sijunzi decoction. This research developed the bases for prospective research associated with Sijunzi decoction, together with being expected to be useful to rapidly extract and characterize the constituents in other Traditional Chinese herbal formulations. Copyright © 2018 Elsevier B.V. All rights reserved.
Rapid identification of Clostridium species by high-pressure liquid chromatography.
Harpold, D J; Wasilauskas, B L; O'Connor, M L
1985-01-01
High-pressure liquid chromatography was evaluated as a rapid means of identifying various species of clostridia. Isolates were inoculated into a defined medium and incubated aerobically for 1 h at 35 degrees C. The organisms were removed, and the supernatants were derivatized for 1 min at room temperature by the addition of o-phthalaldehyde. The total time required to run each chromatogram was approximately 50 min. Standardized peak heights for each medium component and any new peaks formed were calculated for each isolate and compared with those for uninoculated control medium. Multiple isolates of various Clostridium species gave consistent patterns of medium utilization that could be used for identification. This rapid method can easily be adapted for laboratory use and has the potential for automation. PMID:3905852
Li, Yong; Wu, Xianfu; Li, Jianbei; Wang, Yinghong; Yu, Shishan; Lv, Haining; Qu, Jing; Abliz, Zeper; Liu, Jing; Liu, Yuanyan; Du, Dan
2010-02-01
Cardiac glycosides are a class of naturally occurring compounds that are characterized by some interesting biological activities and are widely distributed in the plant kingdom and can also be found in some animals. There is an interest in the chemical characterization of these molecules due to their toxicity and their use in medicines. In the study reported here, a combination of electrospray ionization tandem mass spectrometry with high-performance liquid chromatography equipped with diode-array detector (HPLC-DAD/ESI-MS(n)), and hyphenation to both liquid chromatography and nuclear magnetic resonance spectroscopy (HPLC/NMR) were utilized for the on-line analyses of cardiac glycosides from Periploca forrestii. The fragmentation patterns and (1)H NMR spectra of nine isolated cardiac glycosides were investigated; their fragmentation rules and (1)H NMR spectral characteristics were summarized and applied to the structural identification of similar constituents in fractions from P. forrestii. As a result, a total of nine trace cardiac glycosides were tentatively determined by analyses of accurate molecular masses, representative fragment ions and characteristic (1)H NMR signals provided by HPLC/high-resolution mass spectrometry (HRMS), HPLC-DAD/ESI-MS(n) and HPLC/(1)H NMR experiments, respectively. Of these, eight (2-9) are new compounds and one (1) is reported from P. forrestii for the first time. Results of the present study can benefit the rapid identification and targeted isolation of new cardiac glycosides from crude plant extracts. 2009 Elsevier B.V. All rights reserved.
Muna, Grace W.; Swope, Vernon M.; Swain, Greg M.; Porter, Marc D.
2011-01-01
This paper reports on preliminary tests of the performance of boron-doped diamond powder (BDDP) as a stationary phase in electrochemically modulated liquid chromatography (EMLC). EMLC manipulates retention through changes in the potential applied (Eappl) to a conductive packing. Porous graphitic carbon (PGC) has routinely been utilized as a material in EMLC separations. Herein the utility of BDDP as a stationary phase in EMLC was investigated and its stability, both compositionally and microstructurally, relative to PGC was compared. The results show that BDDP is stable over a wide range of Eappl values (i.e., −1.2 to +1.2 V vs. Ag/AgCl, sat’d NaCl). The data also reveal that electrostatics play a key role in the adsorption of the aromatic sulfonates on the BDDP stationary phase, and that these analytes are more weakly retained in comparison to the PGC support. The potential for this methodology to provide a means to advance the understanding of molecular adsorption and retention mechanisms on carbonaceous materials is briefly discussed. PMID:18922535
Moskovets, Eugene; Goloborodko, Anton A; Gorshkov, Alexander V; Gorshkov, Mikhail V
2012-07-01
A two-dimensional (2-D) liquid chromatography (LC) separation of complex peptide mixtures that combines a normal phase utilizing hydrophilic interactions and a reversed phase offers reportedly the highest level of 2-D LC orthogonality by providing an even spread of peptides across multiple LC fractions. Matching experimental peptide retention times to those predicted by empirical models describing chromatographic separation in each LC dimension leads to a significant reduction in a database search space. In this work, we calculated the retention times of tryptic peptides separated in the C18 reversed phase at different separation conditions (pH 2 and pH 10) and in TSK gel Amide-80 normal phase. We show that retention times calculated for different 2-D LC separation schemes utilizing these phases start to correlate once the mass range of peptides under analysis becomes progressively narrow. This effect is explained by high degree of correlation between retention coefficients in the considered phases. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
21 CFR 862.2250 - Gas liquid chromatography system for clinical use.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Gas liquid chromatography system for clinical use... Instruments § 862.2250 Gas liquid chromatography system for clinical use. (a) Identification. A gas liquid... pressure. The device may include accessories such as columns, gases, column supports, and liquid coating...
21 CFR 862.2250 - Gas liquid chromatography system for clinical use.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Gas liquid chromatography system for clinical use... Instruments § 862.2250 Gas liquid chromatography system for clinical use. (a) Identification. A gas liquid... pressure. The device may include accessories such as columns, gases, column supports, and liquid coating...
21 CFR 862.2250 - Gas liquid chromatography system for clinical use.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Gas liquid chromatography system for clinical use... Instruments § 862.2250 Gas liquid chromatography system for clinical use. (a) Identification. A gas liquid... pressure. The device may include accessories such as columns, gases, column supports, and liquid coating...
21 CFR 862.2250 - Gas liquid chromatography system for clinical use.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gas liquid chromatography system for clinical use... Instruments § 862.2250 Gas liquid chromatography system for clinical use. (a) Identification. A gas liquid... pressure. The device may include accessories such as columns, gases, column supports, and liquid coating...
21 CFR 862.2250 - Gas liquid chromatography system for clinical use.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Gas liquid chromatography system for clinical use... Instruments § 862.2250 Gas liquid chromatography system for clinical use. (a) Identification. A gas liquid... pressure. The device may include accessories such as columns, gases, column supports, and liquid coating...
Pailan, Santanu; Saha, Pradipta
2015-01-01
An organophosphate (OP) degrading chemotactic bacterial strain BUR11 isolated from an agricultural field was identified as a member of Pseudomonas genus on the basis of its 16S rRNA gene sequence. The strain could utilize parathion, chlorpyrifos and their major hydrolytic intermediates as sole source of carbon for its growth and exhibited positive chemotactic response towards most of them. Optimum concentration of parathion for its growth was recorded to be 200 ppm and 62% of which was degraded within 96 h at 37 °C. Growth studies indicated the strain to be moderately thermo-halo tolerant in nature. Investigation based on identification of intermediates of parathion degradation by thin layer chromatography (TLC), high performance liquid chromatography (HPLC), gas chromatography (GC) and liquid chromatography mass spectrometry (LC-MS/MS) provided evidence for possible existence of two pathways. The first pathway proceeds via 4-nitrophenol (4-NP) while the second proceeds through formation of 4-aminoparathion (4-APar), 4-aminophenol (4-AP) and parabenzoquinone (PBQ). This is the first report of chemotaxis towards organophosphate compound by a thermo-halo tolerant bacterium.
Pailan, Santanu
2015-01-01
An organophosphate (OP) degrading chemotactic bacterial strain BUR11 isolated from an agricultural field was identified as a member of Pseudomonas genus on the basis of its 16S rRNA gene sequence. The strain could utilize parathion, chlorpyrifos and their major hydrolytic intermediates as sole source of carbon for its growth and exhibited positive chemotactic response towards most of them. Optimum concentration of parathion for its growth was recorded to be 200 ppm and 62% of which was degraded within 96 h at 37 °C. Growth studies indicated the strain to be moderately thermo-halo tolerant in nature. Investigation based on identification of intermediates of parathion degradation by thin layer chromatography (TLC), high performance liquid chromatography (HPLC), gas chromatography (GC) and liquid chromatography mass spectrometry (LC-MS/MS) provided evidence for possible existence of two pathways. The first pathway proceeds via 4-nitrophenol (4-NP) while the second proceeds through formation of 4-aminoparathion (4-APar), 4-aminophenol (4-AP) and parabenzoquinone (PBQ). This is the first report of chemotaxis towards organophosphate compound by a thermo-halo tolerant bacterium. PMID:26587344
Douša, Michal; Pivoňková, Veronika; Sýkora, David
2016-08-01
A rapid procedure for the determination of memantine based on hydrophilic interaction chromatography with fluorescence detection was developed. Fluorescence detection after postcolumn derivatization with o-phtaldialdehyde/2-mercaptoethanol was performed at excitation and emission wavelengths of 345 and 450 nm, respectively. The postcolumn reaction conditions such as reaction temperature, derivatization reagent flow rate, and reagents concentration were studied due to steric hindrance of amino group of memantine. The derivatization reaction was applied for the hydrophilic interaction liquid chromatography method which was based on Cogent Silica-C stationary phase with a mobile phase consisting of a mixture of 10 mmol/L citric acid and 10 mmol/L o-phosphoric acid (pH 6.0) with acetonitrile using an isocratic composition of 2:8 v/v. The benefit of the reported approach consists in a simple sample pretreatment and a quick and sensitive hydrophilic interaction chromatography method. The developed method was validated in terms of linearity, accuracy, precision, and selectivity according to the International Conference on Harmonisation guidelines. The developed method was successfully applied for the analysis of commercial memantine tablets. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
High Performance Liquid Chromatography Experiments to Undergraduate Laboratories
ERIC Educational Resources Information Center
Kissinger, Peter T.; And Others
1977-01-01
Reviews the principles of liquid chromatography with electrochemical detection (LCEC), an analytical technique that incorporates the advantages of both liquids chromatography and electrochemistry. Also suggests laboratory experiments using this technique. (MLH)
Use of high pressure liquid chromatography in the study of liquid lubricant oxidation
NASA Technical Reports Server (NTRS)
Morales, W.
1982-01-01
The general principles of classical liquid chromatography and high-pressure liquid chromatography (HPLC) are reviewed, and their advantages and disadvantages are compared. Several chromatographic techniques are reviewed, and the analysis of a C-ether liquid lubricant by each technique is illustrated. An analysis by size exclusion chromatography of an ester lubricant, which had been degraded using a micro-oxidation apparatus, is illustrated to show how HPLC can be used in the study of high-temperature lubricant degradation.
Markó, Lajos; Molnár, Gergo Attila; Wagner, Zoltán; Koszegi, Tamás; Matus, Zoltán; Mohás, Márton; Kuzma, Mónika; Szijártó, István András; Wittmann, István
2008-01-13
Hypertension as well as type 2 diabetes mellitus is a major factor in population mortality. Both diseases damage the endothelium, the early sign of which is microalbuminuria, which can be screened by dipstick and can be diagnosed by using immuno-based and high performance liquid chromatography methods. Using high performance liquid chromatography, the non-immunoreactive albumin can be detected as well. The authors aimed at the examination of albuminuria in the case of immunonephelometrically negative patients with high performance liquid chromatography, in diabetic and hypertensive and non-diabetic hypertensive populations. The authors also wanted to compare the present (albumin-creatinine ratio: male: > or =2.5 mg/mmol, female: > or =3.5 mg/mmol) and a new criteria of the Heart Outcomes Prevention Evaluation study (patients without diabetes: immunological method, > or =0.7 mg/mmol; high performance liquid chromatography, > or =3.1 mg/mmol; individuals with diabetes: immunological method, > or =1.4 mg/mmol; high performance liquid chromatography, > or =5.2 mg/mmol) of microalbuminuria. Examination of fresh urines of 469 microalbuminuria negative patients by dipstick were performed by immunonephelometry. Patients, who were microalbuminuria negative by immunonephelometry as well, were further analyzed by high performance liquid chromatography using the Accumintrade mark Kit, based on size-exclusion chromatography. Three times higher albuminuria were found with high performance liquid chromatography than with immunonephelometry. The intraindividual coefficient of variation did not differ in the two methods (37 +/- 31% vs. 40 +/- 31%, p = 0.869; immunonephelometry vs. high performance liquid chromatography; mean +/- standard deviation). Using the present criteria for microalbuminuria, 43% of immunonephelometrically negative patients proved to be microalbuminuric by high performance liquid chromatography. Using the new criteria of the Heart Outcomes Prevention Evaluation study, the rate of microalbuminuria positivity among the immunonephelometrically negative patients decreased to 14.5% by high performance liquid chromatography and the decrease in the number of microalbuminuria positive cases by high performance liquid chromatography could be observed mainly in the diabetic and hypertensive group (49% vs. 7.5%), while slighter decrease could be observed in the non-diabetic hypertensive group (37% vs. 26.5%). Applying the traditional criteria, the strongest predictor was the male gender by the logistic regression analysis. In 28% of microalbuminuria negative patients by immunonephelometry the diagnosis of microalbuminuria can be established using high performance liquid chromatography. Almost in one-third of microalbuminuria negative patients by immunonephelometry the diagnosis of microalbuminuria can be established by high performance liquid chromatography for which diagnosis three constitutive urine examinations are still needed. New criteria determined by the Heart Outcomes Prevention Evaluation study can be used neither in case of diabetic and hypertensive patients, nor in the case of non-diabetic hypertensive patients. The gender as the most important predictor of microalbuminuria cannot be ignored.
Tassi, Marco; De Vos, Jelle; Chatterjee, Sneha; Sobott, Frank; Bones, Jonathan; Eeltink, Sebastiaan
2018-01-01
The characterization of biotherapeutics represents a major analytical challenge. This review discusses the current state-of-the-art in analytical technologies to profile biopharma products under native conditions, i.e., the protein three dimensional conformation is maintained during liquid chromatographic analysis. Native liquid-chromatographic modes that are discussed include aqueous size-exclusion chromatography, hydrophobic interaction chromatography, and ion-exchange chromatography. Infusion conditions and the possibilities and limitations to hyphenate native liquid chromatography to mass spectrometry are discussed. Furthermore, the applicability of native liquid-chromatography methods and intact mass spectrometry analysis for the characterization of monoclonal antibodies and antibody-drug conjugates is discussed. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Gradient stationary phase optimized selectivity liquid chromatography with conventional columns.
Chen, Kai; Lynen, Frédéric; Szucs, Roman; Hanna-Brown, Melissa; Sandra, Pat
2013-05-21
Stationary phase optimized selectivity liquid chromatography (SOSLC) is a promising technique to optimize the selectivity of a given separation. By combination of different stationary phases, SOSLC offers excellent possibilities for method development under both isocratic and gradient conditions. The so far available commercial SOSLC protocol utilizes dedicated column cartridges and corresponding cartridge holders to build up the combined column of different stationary phases. The present work is aimed at developing and extending the gradient SOSLC approach towards coupling conventional columns. Generic tubing was used to connect short commercially available LC columns. Fast and base-line separation of a mixture of 12 compounds containing phenones, benzoic acids and hydroxybenzoates under both isocratic and linear gradient conditions was selected to demonstrate the potential of SOSLC. The influence of the connecting tubing on the deviation of predictions is also discussed.
Hinchliffe, Edward; Rudge, James; Reed, Paul
2016-07-01
Measurement of vitamin A (retinol) and E (alpha-tocopherol) in UK clinical laboratories is currently performed exclusively by high-performance liquid chromatography with ultraviolet detection. We investigated whether retinol and alpha-tocopherol could be measured simultaneously by liquid chromatography tandem mass spectrometry. Serum samples (100 μL) were extracted using Isolute + Supported Liquid Extraction plates. Chromatography was performed on a Phenomenex Kinetex Biphenyl 2.6 μm, 50 × 2.1 mm column, and liquid chromatography tandem mass spectrometry on a Waters Acquity TQD. Injection-to-injection time was 4.3 min. The assay was validated according to published guidelines. Patient samples were used to compare liquid chromatography tandem mass spectrometry and high-performance liquid chromatography with ultraviolet detection methods. For retinol and alpha-tocopherol, respectively, the assay was linear up to 6.0 and 80.0 μmol/L, and lower limit of quantification was 0.07 and 0.26 μmol/L. Intra and interassay imprecision were within desirable analytical specifications. Analysis of quality control material aligned to NIST SRM 968e, and relative spiked recovery from human serum, both yielded results within 15% of target values. Method comparison with high-performance liquid chromatography with ultraviolet detection methodology demonstrated a negative bias for retinol and alpha-tocopherol by the liquid chromatography tandem mass spectrometry method. Analysis of United Kingdom National External Quality Assurance Scheme samples yielded mean bias from the target value of +3.0% for retinol and -11.2% for alpha-tocopherol. We have developed a novel, high-throughput method for extraction of retinol and alpha-tocopherol from human serum followed by simultaneous quantitation by liquid chromatography tandem mass spectrometry. The method offers a rapid, sensitive, specific and cost-effective alternative to high-performance liquid chromatography with ultraviolet detection methodology, and is suitable for routine clinical monitoring of patients predisposed to fat-soluble vitamin malabsorption. © The Author(s) 2015.
ERIC Educational Resources Information Center
Majors, Ronald E.; And Others
1984-01-01
Reviews literature covering developments of column liquid chromatography during 1982-83. Areas considered include: books and reviews; general theory; columns; instrumentation; detectors; automation and data handling; multidimensional chromatographic and column switching techniques; liquid-solid chromatography; normal bonded-phase, reversed-phase,…
Gavioli, Elena; Maier, Norbert M; Minguillón, Cristina; Lindner, Wolfgang
2004-10-01
A countercurrent chromatography protocol for support-free preparative enantiomer separation of the herbicidal agent 2-(2,4-dichlorphenoxy)propionic acid (dichlorprop) was developed utilizing a purposefully designed, highly enantioselective chiral stationary-phase additive (CSPA) derived from bis-1,4-(dihydroquinidinyl)phthalazine. Guided by liquid-liquid extraction experiments, a solvent system consisting of 10 mM CSPA in methyl tert-butyl ether and 100 mM sodium phosphate buffer (pH 8.0) was identified as a suitable stationary/mobile-phase combination. This solvent system provided an ideal compromise among stationary-phase retention, enantioselectivity, and well-balanced analyte distribution behavior. Using a commercial centrifugal partition chromatography instrument, complete enantiomer separations of up to 366 mg of racemic dichlorprop could be achieved, corresponding to a sample load being equivalent to the molar amount of CSPA employed. Comparison of the preparative performance characteristics of the CPC protocol with that of a HPLC separation using a silica-supported bis-1,4-(dihydroquinidinyl)phthalazine chiral stationary phase CSP revealed comparable loading capacities for both techniques but a significantly lower solvent consumption for CPC. With respect to productivity, HPLC was found to be superior, mainly due to inherent flow rate restrictions of the CPC instrument. Given that further progress in instrumental design and engineering of dedicated, highly enantioselective CSPAs can be achieved, CPC may offer a viable alternative to CSP-based HPLC for preparative-scale enantiomer separation.
Wang, Fang-Xu; Yuan, Jian-Chao; Kang, Li-Ping; Pang, Xu; Yan, Ren-Yi; Zhao, Yang; Zhang, Jie; Sun, Xin-Guang; Ma, Bai-Ping
2016-09-10
An ultra high-performance liquid chromatography quadrupole time-of-flight tandem mass spectrometry approach coupled with multivariate statistical analysis was established and applied to rapidly distinguish the chemical differences between fibrous root and rhizome of Anemarrhena asphodeloides. The datasets of tR-m/z pairs, ion intensity and sample code were processed by principal component analysis and orthogonal partial least squares discriminant analysis. Chemical markers could be identified based on their exact mass data, fragmentation characteristics, and retention times. And the new compounds among chemical markers could be isolated rapidly guided by the ultra high-performance liquid chromatography quadrupole time-of-flight tandem mass spectrometry and their definitive structures would be further elucidated by NMR spectra. Using this approach, twenty-four markers were identified on line including nine new saponins and five new steroidal saponins of them were obtained in pure form. The study validated this proposed approach as a suitable method for identification of the chemical differences between various medicinal parts in order to expand medicinal parts and increase the utilization rate of resources. Copyright © 2016 Elsevier B.V. All rights reserved.
Fan, Yunpeng; Fu, Yanhui; Fu, Qing; Cai, Jianfeng; Xin, Huaxia; Dai, Mei; Jin, Yu
2016-07-01
An orthogonal (71.9%) off-line preparative two-dimensional normal-phase liquid chromatography/reversed-phase liquid chromatography method coupled with effective sample pretreatment was developed for separation and purification of flavonoids from licorice. Most of the nonflavonoids were firstly removed using a self-made Click TE-Cys (60 μm) solid-phase extraction. In the first dimension, an industrial grade preparative chromatography was employed to purify the crude flavonoids. Click TE-Cys (10 μm) was selected as the stationary phase that provided an excellent separation with high reproducibility. Ethyl acetate/ethanol was selected as the mobile phase owing to their excellent solubility for flavonoids. Flavonoids co-eluted in the first dimension were selected for further purification using reversed-phase liquid chromatography. Multiple compounds could be isolated from one normal-phase fraction and some compounds with bad resolution in one-dimensional liquid chromatography could be prepared in this two-dimensional system owing to the orthogonal separation. Moreover, this two-dimensional liquid chromatography method was beneficial for the preparation of relatively trace flavonoid compounds, which were enriched in the first dimension and further purified in the second dimension. Totally, 24 flavonoid compounds with high purity were obtained. The results demonstrated that the off-line two-dimensional liquid chromatography method was effective for the preparative separation and purification of flavonoids from licorice. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Qu, Jing; Hu, You-cai; Li, Jian-bei; Wang, Ying-hong; Zhang, Jin-lan; Abliz, Zeper; Yu, Shi-shan; Liu, Yun-bao
2008-01-01
A combination of electrospray ionization tandem mass spectrometry with high-performance liquid chromatography (HPLC/ESI-MSn), and hyphenation of liquid chromatography to nuclear magnetic resonance spectroscopy (HPLC/NMR), have been extensively utilized for on-line analysis of natural products, analyzing metabolite and drug impurity. In our last paper, we reported an on-line analytical method for structural identification of trace alkaloids in the same class. However, the structural types of the constituents in plants were various, such as flavanoids, terpenoids and steroids. It is important to establish an effective analytical method for on-line structural identification of constituents with molecular diversity in extracts of plants. So, in the present study, the fragmentation patterns of some isolated stilbenes, phloroglucinols and flavanoids from Lysidice rhodostegia were investigated by ESI-MSn. Their fragmentation rules and UV characteristics are summarized, and the relationship between the spectral characteristics, rules and the structures is described. According to the fragmentation rules, NMR and UV spectral characteristics, 24 constituents of different types in the fractions from L. brevicalyx of the same genus were structurally characterized on the basis of HPLC/HRMS, HPLC-UV/ESI-MSn, HPLC/1H NMR and HPLC/1H-1H COSY rapidly. Of these, six (10, 13, 14, 16, 17 and 23) are new compounds and all of them are reported from L. brevicalyx for the first time. The aim is to develop an effective analytical method for on-line structural identification of natural products with molecular diversity in plants, and to guide the rapid and direct isolation of novel compounds by chemical screening.
NASA Astrophysics Data System (ADS)
Compton, Duane C.; Snapp, Robert R.
2007-09-01
TWiGS (two-dimensional wavelet transform with generalized cross validation and soft thresholding) is a novel algorithm for denoising liquid chromatography-mass spectrometry (LC-MS) data for use in "shot-gun" proteomics. Proteomics, the study of all proteins in an organism, is an emerging field that has already proven successful for drug and disease discovery in humans. There are a number of constraints that limit the effectiveness of liquid chromatography-mass spectrometry (LC-MS) for shot-gun proteomics, where the chemical signals are typically weak, and data sets are computationally large. Most algorithms suffer greatly from a researcher driven bias, making the results irreproducible and unusable by other laboratories. We thus introduce a new algorithm, TWiGS, that removes electrical (additive white) and chemical noise from LC-MS data sets. TWiGS is developed to be a true two-dimensional algorithm, which operates in the time-frequency domain, and minimizes the amount of researcher bias. It is based on the traditional discrete wavelet transform (DWT), which allows for fast and reproducible analysis. The separable two-dimensional DWT decomposition is paired with generalized cross validation and soft thresholding. The Haar, Coiflet-6, Daubechie-4 and the number of decomposition levels are determined based on observed experimental results. Using a synthetic LC-MS data model, TWiGS accurately retains key characteristics of the peaks in both the time and m/z domain, and can detect peaks from noise of the same intensity. TWiGS is applied to angiotensin I and II samples run on a LC-ESI-TOF-MS (liquid-chromatography-electrospray-ionization) to demonstrate its utility for the detection of low-lying peaks obscured by noise.
Burton, Casey; Shi, Honglan; Ma, Yinfa
2013-11-19
Recent preliminary studies have implicated urinary pteridines as candidate biomarkers in a growing number of malignancies including breast cancer. While the developments of capillary electrophoresis-laser induced fluorescence (CE-LIF), high performance liquid chromatography (HPLC), and liquid chromatography-mass spectroscopy (LC-MS) pteridine urinalyses among others have helped to enable these findings, limitations including poor pteridine specificity, asynchronous or nonexistent renal dilution normalization, and a lack of information regarding adduct formation in mass spectrometry techniques utilizing electrospray ionization (ESI) have prevented application of these techniques to a larger clinical setting. In this study, a simple, rapid, specific, and sensitive high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method has been developed and optimized for simultaneous detection of six pteridines previously implicated in breast cancer and creatinine as a renal dilution factor in urine. In addition, this study reports cationic adduct formation of urinary pteridines under ESI-positive ionization for the first time. This newly developed technique separates and detects the following six urinary pteridines: 6-biopterin, 6-hydroxymethylpterin, d-neopterin, pterin, isoxanthopterin, and xanthopterin, as well as creatinine. The method detection limit for the pteridines is between 0.025 and 0.5 μg/L, and for creatinine, it is 0.15 μg/L. The method was also validated by spiked recoveries (81-105%), reproducibility (RSD: 1-6%), and application to 25 real urine samples from breast cancer positive and negative samples through a double-blind study. The proposed technique was finally compared directly with a previously reported CE-LIF technique, concluding that additional or alternative renal dilution factors are needed for proper investigation of urinary pteridines as breast cancer biomarkers.
Wang, Yun; Liu, Hui; Shen, Lifeng; Yao, Lan; Ma, Yinlian; Yu, Dingrong; Chen, Jianhong; Li, Puling; Chen, Ying; Zhang, Cun
2015-12-01
Gardeniae fructus is one of the most frequently used herbs in traditional Chinese medicine. In the present study, a process for the enrichment of six iridoid glycosides from Gardeniae fructus was developed using medium-pressure liquid chromatography combined with macroporous resin and reversed-phase chromatography. The purities of different fractions from Gardeniae fructus were assessed using quantitative high-performance liquid chromatography. After fractionation using HPD-100 column chromatography, a 30% ethanol fraction was selected based on high-performance liquid chromatography and liquid chromatography with mass spectrometry qualitative analysis to separate and purify. Based on the orientation analysis results, six compounds-deacetyl asperulosidic acid methyl ester, gardenoside, ixoroside, scandoside methyl ester, genipin-1-O-β-d-gentiobioside, and geniposide-were successfully isolated and purified in three to four combined steps from Gardeniae fructus. The purities of these compounds were found by high-performance liquid chromatography analysis to be 97.9, 98.1, 95.5, 96.3, 97.1, and 98.7%, respectively. Moreover, their structures were elucidated by NMR spectroscopy and liquid chromatography with tandem mass spectrometry. The separation process was highly efficient, rapid, and accurate, making it a potential approach for the large-scale production of iridoids in the laboratory and providing several marker compounds for quality control. This procedure may be meaningful for the purification of other natural products used in traditional Chinese medicine. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Challal, Soura; Queiroz, Emerson Ferreira; Debrus, Benjamin; Kloeti, Werner; Guillarme, Davy; Gupta, Mahabir Prashad; Wolfender, Jean-Luc
2015-11-01
In natural product research, the isolation of biomarkers or bioactive compounds from complex natural extracts represents an essential step for de novo identification and bioactivity assessment. When pure natural products have to be obtained in milligram quantities, the chromatographic steps are generally labourious and time-consuming. In this respect, an efficient method has been developed for the reversed-phase gradient transfer from high-performance liquid chromatography to medium-performance liquid chromatography for the isolation of pure natural products at the level of tens of milligrams from complex crude natural extracts. The proposed method provides a rational way to predict retention behaviour and resolution at the analytical scale prior to medium-performance liquid chromatography, and guarantees similar performances at both analytical and preparative scales. The optimisation of the high-performance liquid chromatography separation and system characterisation allows for the prediction of the gradient at the medium-performance liquid chromatography scale by using identical stationary phase chemistries. The samples were introduced in medium-performance liquid chromatography using a pressure-resistant aluminium dry load cell especially designed for this study to allow high sample loading while maintaining a maximum achievable flow rate for the separation. The method has been validated with a mixture of eight natural product standards. Ultraviolet and evaporative light scattering detections were used in parallel for a comprehensive monitoring. In addition, post-chromatographic mass spectrometry detection was provided by high-throughput ultrahigh-performance liquid chromatography time-of-flight mass spectrometry analyses of all fractions. The processing of all liquid chromatography-mass spectrometry data in the form of an medium-performance liquid chromatography x ultra high-performance liquid chromatography time-of-flight mass spectrometry matrix enabled an efficient localisation of the compounds of interest in the generated fractions. The methodology was successfully applied for the separation of three different plant extracts that contain many diverse secondary metabolites. The advantages and limitations of this approach and the theoretical chromatographic background that rules such as liquid chromatography gradient transfer are presented from a practical viewpoint. Georg Thieme Verlag KG Stuttgart · New York.
Liquid Chromatography in 1982.
ERIC Educational Resources Information Center
Freeman, David H.
1982-01-01
Reviews trends in liquid chromatography including apparatus, factors affecting efficient separation of a mixture (peak sharpness and speed), simplified problem-solving, adsorption, bonded phase chromatography, ion selectivity, and size exclusion. The current trend is to control chemical selectivity by the liquid phase. (Author/JN)
García, J B; Tormo, José R
2003-06-01
A new tool, HPLC Studio, was developed for the comparison of high-performance liquid chromatography (HPLC) chromatograms from microbial extracts. The new utility makes it possible to create a virtual chromatogram by mixing up to 20 individual chromatograms. The virtual chromatogram is the first step in establishing a ranking of the microbial fermentation conditions based on either the area or diversity of HPLC peaks. The utility was used to maximize the diversity of secondary metabolites tested from a microorganism and therefore increase the chances of finding new lead compounds in a drug discovery program.
NASA Technical Reports Server (NTRS)
1983-01-01
The general principles of classical liquid chromatography and high pressure liquid chromatography (HPLC) are reviewed, and their advantages and disadvantages are compared. Several chromatographic techniques are reviewed, and the analytical separation of a C-ether liquid lubricant by each technique is illustrated. A practical application of HPLC is then demonstrated by analyzing a degraded C-ether liquid lubricant from full scale, high temperature bearing tests.
[High-performance liquid-liquid chromatography in beverage analysis].
Bricout, J; Koziet, Y; de Carpentrie, B
1978-01-01
Liquid liquid chromatography was performed with columns packed with stationary phases chemically bonded to silica microparticules. These columns show a high efficiency and are used very easily. Flavouring compounds like aromatic aldehydes which have a low volatility were analyzed in brandy using a polar phase alkylnitrile. Sapid substances like amarogentin in Gentiana lutea or glyryrrhizin in Glycyrrhiza glabra were determined by reversed phase chromatography. Finally ionizable substances like synthetic dyes can be analyzed by paired ion chromatography witha non polar stationary phase.
Tisdall, P A; DeYoung, D R; Roberts, G D; Anhalt, J P
1982-01-01
Identification of routine mycobacterial isolates by gas-liquid chromatography profile analysis was performed on 335 strains received at the Mayo Clinic over a 10-month period. Comparison of identification by gas-liquid chromatography versus conventional biochemical profiles was made. The two methods agreed on the identification of 320 isolates, with gas-liquid chromatography profiling making eight errors and biochemical profiling making four errors. In three cases, discrepancies could not be resolved. PMID:6811612
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wunschel, David S.; Valenzuela, Blandina R.; Kaiser, Brooke L. Deatherage
A variety of toxins are produced by marine and freshwater microorganisms that present a threat to human health. These toxins have diverse chemical properties and specifically, a range of hydrophobicity. Methods for extraction and identification of these toxins are often geared toward specific classes of toxin depending on the sample type. There is a need for a general method of toxin extraction and identification for screening samples where the likely toxin content is not known a priori. Here, we have applied a general method for metabolite extraction to toxin containing samples. This method was coupled with a simple dual liquidmore » chromatography approach for separating a broad range of toxins. This liquid chromatography approach was coupled to triple quadrupole and quadrupole time-of-flight MS/MS platforms. The method was testing on a fish matrix for recovery of palytoxin as well as marine corals for detection of natural mixtures of palytoxin analogues. The recovery of palytoxin was found to produce a linear response (R 2 of 0.95) when spiked into the fish matrix with a limit of quantitation of 2.5 ng/μL and recovery efficiency of 73% +/- 9%. The screening of corals revealed varying amount of palytoxin, and in one case, different palytoxin structural analogues. This demonstration illustrates the potential utility of this method for toxin extraction and detection.« less
Wunschel, David S.; Valenzuela, Blandina R.; Kaiser, Brooke L. Deatherage; ...
2018-05-09
A variety of toxins are produced by marine and freshwater microorganisms that present a threat to human health. These toxins have diverse chemical properties and specifically, a range of hydrophobicity. Methods for extraction and identification of these toxins are often geared toward specific classes of toxin depending on the sample type. There is a need for a general method of toxin extraction and identification for screening samples where the likely toxin content is not known a priori. Here, we have applied a general method for metabolite extraction to toxin containing samples. This method was coupled with a simple dual liquidmore » chromatography approach for separating a broad range of toxins. This liquid chromatography approach was coupled to triple quadrupole and quadrupole time-of-flight MS/MS platforms. The method was testing on a fish matrix for recovery of palytoxin as well as marine corals for detection of natural mixtures of palytoxin analogues. The recovery of palytoxin was found to produce a linear response (R 2 of 0.95) when spiked into the fish matrix with a limit of quantitation of 2.5 ng/μL and recovery efficiency of 73% +/- 9%. The screening of corals revealed varying amount of palytoxin, and in one case, different palytoxin structural analogues. This demonstration illustrates the potential utility of this method for toxin extraction and detection.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wittmann, S.; Decsy, Z.; Regensperger, S.
1984-01-01
The separation and determination of groups of alkylphenols with C/sub 15/-C/sub 33/ isoalkane chains by gas chromatography, elution liquid chromatography, and gel permeation chromatography are described. Paraffinic hydrocarbons, monoalkylphenols, dialkylphenols, and bis(hydroxyphenyl)alkanes were identified in industrial alkylphenols by mass spectrometry. 7 references, 3 figures, 2 tables.
Zhou, Xuan; Chen, Cen; Ye, Xiaolan; Song, Fenyun; Fan, Guorong; Wu, Fuhai
2017-01-01
In this paper, by coupling reversed phase liquid chromatography (RPLC) and hydrophilic interaction liquid chromatography (HILIC), a two-dimensional liquid chromatography system was developed for separation and identification of the active ingredients in Gardenia jasminoides Ellis (GJE). By applying the semi-preparative C18 column as the first dimension and the core-shell column as the second dimension, a total of 896 peaks of GJE were separated. Among the 896 peaks, 16 active ingredients including geniposide, gardenoside, gardoside, etc. were identified by mass spectrometry analysis. The results indicated that the proposed two-dimensional RPLC/HILIC system was an effective method for the analysis of GJE and might hold a high potential to become a useful tool for analysis of other complex mixtures. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kertesz, Vilmos; Van Berkel, Gary J
2010-01-01
In this work, a commercially available autosampler was adapted to perform direct liquid microjunction (LMJ) surface sampling followed by a high-pressure liquid chromatography (HPLC) separation of the extract components and detection with electrospray ionization mass spectrometry (ESI-MS). To illustrate the utility of coupling a separation with this direct liquid extraction based surface sampling approach, four different organs (brain, lung, kidney, and liver) from whole-body thin tissue sections of propranolol dosed and control mice were examined. The parent drug was observed in the chromatograms of the surface sampling extracts from all the organs of the dosed mouse examined. In addition, twomore » isomeric phase II metabolites of propranolol (an aliphatic and an aromatic hydroxypropranolol glucuronide) were observed in the chromatograms of the extracts from lung, kidney, and liver. Confirming the presence of one or the other or both of these glucuronides in the extract from the various organs was not possible without the separation. These drug and metabolite data obtained using the LMJ surface sampling/HPLC-MS method and the results achieved by analyzing similar samples by conventional extraction of the tissues and subsequent HPLC-MS analysis were consistent.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ovchinnikova, Olga S; Kertesz, Vilmos; Van Berkel, Gary J
This paper describes the coupling of ambient pressure transmission geometry laser ablation with a liquid phase sample collection method for surface sampling and ionization with subsequent mass spectral analysis. A commercially available autosampler was adapted to produce a liquid droplet at the end of the syringe injection needle while in close proximity to the surface to collect the sample plume produced by laser ablation. The sample collection was followed by either flow injection or a high performance liquid chromatography (HPLC) separation of the extracted components and detection with electrospray ionization mass spectrometry (ESI-MS). To illustrate the analytical utility of thismore » coupling, thin films of a commercial ink sample containing rhodamine 6G and of mixed isobaric rhodamine B and 6G dyes on glass microscope slides were analyzed. The flow injection and HPLC/ESI-MS analysis revealed successful laser ablation, capture and, with HPLC, the separation of the two compounds. The ablated circular area was about 70 m in diameter for these experiments. The spatial sampling resolution afforded by the laser ablation, as well as the ability to use sample processing methods like HPLC between the sample collection and ionization steps, makes this combined surface sampling/ionization technique a highly versatile analytical tool.« less
A simple high performance liquid chromatography method for determination of rebamipide in rat urine.
Cooper, Dustin L; Harirforoosh, Sam
2014-01-01
Rebamipide is a mucoprotective agent commonly used to prevent nonsteriodal anti-inflammatory drug-induced gastrointenstinal side effects [1]. Human plasma and urine analysis of rebamipide utilizing high performance liquid chromatography (HPLC) have been reported [2]. Recently, we reported on the plasma levels of rebamipide in presense or absence of celecoxib or diclofenac in rats [3] using a modified HPLC method of detection developed by Jeoung et al. [4]. To tailor the method towards use in urinary rebamipide extraction and analysis, the following modifications were made:•To compensate for high concentrations of rebamipide found in urine, a new rebamipide stock solution was prepared with a final concentration of 50,000 ng/mL.•Rat urine calibration standards were obtained within the range of 50-1000 ng/mL and 1000-50,000 ng/mL.•Plasma samples were replaced with urine samples.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shi, Tujin; Zhou, Jianying; Gritsenko, Marina A.
2012-02-01
Interest in the application of advanced proteomics technologies to human blood plasma- or serum-based clinical samples for the purpose of discovering disease biomarkers continues to grow; however, the enormous dynamic range of protein concentrations in these types of samples (often >10 orders of magnitude) represents a significant analytical challenge, particularly for detecting low-abundance candidate biomarkers. In response, immunoaffinity separation methods for depleting multiple high- and moderate-abundance proteins have become key tools for enriching low-abundance proteins and enhancing detection of these proteins in plasma proteomics. Herein, we describe IgY14 and tandem IgY14-Supermix separation methods for removing 14 high-abundance and up tomore » 60 moderate-abundance proteins, respectively, from human blood plasma and highlight their utility when combined with liquid chromatography-tandem mass spectrometry for interrogating the human plasma proteome.« less
Millán, S; Sampedro, M C; Unceta, N; Goicolea, M A; Rodríguez, E; Barrio, R J
2003-05-02
A solid-phase microextraction (SPME) method coupled to high-performance liquid chromatography with diode array detection (HPLC-DAD) for the analysis of six organochlorine fungicides (nuarimol, triadimenol, triadimefon, folpet, vinclozolin and penconazole) in wine was developed. For this purpose, polydimethylsiloxane-divinylbenzene-coated fibers were utilized and all factors affecting throughput, precision, and accuracy of the SPME method were investigated and optimized. These factors include: matrix influence, extraction and desorption time, percentage of ethanol, pH, salt effect and desorption mode. The performed analytical procedure showed detectability ranging from 4 to 27 microg l(-1) and precision from 2.4 to 14.2% (as intra-day relative standard deviation, RSD) and 4.7-25.7% (as inter-day RSD) depending on the fungicide. The results demonstrate the suitability of the SPME-HPLC-DAD method to analyze these organochlorine fungicides in red wine.
Ye, Guangming; Cai, Xuejian; Wang, Biao; Zhou, Zhongxian; Yu, Xiaohua; Wang, Weibin; Zhang, Jiandong; Wang, Yuhai; Dong, Jierong; Jiang, Yunyun
2008-11-04
A simple, accurate and rapid method for simultaneous analysis of vancomycin and ceftazidime in cerebrospinal fluid (CSF), utilizing high-performance liquid chromatography (HPLC), has been developed and thoroughly validated to satisfy strict FDA guidelines for bioanalytical methods. Protein precipitation was used as the sample pretreatment method. In order to increase the accuracy, tinidazole was chosen as the internal standard. Separation was achieved on a Diamonsil C18 column (200 mm x 4.6mm I.D., 5 microm) using a mobile phase composed of acetonitrile and acetate buffer (pH 3.5) (8:92, v/v) at room temperature (25 degrees C), and the detection wavelength was 240 nm. All the validation data, such as accuracy, precision, and inter-day repeatability, were within the required limits. The method was applied to determine vancomycin and ceftazidime concentrations in CSF in five craniotomy patients.
Sakuragawa, A; Yoneno, T; Inoue, K; Okutani, T
1999-06-04
This study describes the utilization of carbonyl- 2,4-dinitrophenylhydrazine (DNPH) derivatives for the determination of a micro amount of carbonyl compounds in air by liquid chromatography-mass spectrometry (LC-MS). After the carbonyl compounds are collected using a Waters Sep-Pak C18 cartridge column with-impregnated DNPH on octadecylsilica, they are eluted by acetonitrile as carbonyl-DNPH derivatives. A 20-mm3 aliquot of eluent is injected into the LC-MS system. The four derivatives (formaldehyde-, acetaldehyde-, acrolein- and acetone-DNPH) were eluted within 7 min with acetonitrile-water (60:40, v/v) as the mobile phase. The proposed method offers sub-ppb sensitivity and good reproducibility and was applied to the determination of these carbonyl compounds in actual air samples from store rooms, laboratories and offices. The relative standard deviations for these samples (n = 6) were 1 to 3%.
NASA Astrophysics Data System (ADS)
Tang, Yang; Wei, Juan; Costello, Catherine E.; Lin, Cheng
2018-04-01
The occurrence of numerous structural isomers in glycans from biological sources presents a severe challenge for structural glycomics. The subtle differences among isomeric structures demand analytical methods that can provide structural details while working efficiently with on-line glycan separation methods. Although liquid chromatography-tandem mass spectrometry (LC-MS/MS) is a powerful tool for mixture analysis, the commonly utilized collision-induced dissociation (CID) method often does not generate a sufficient number of fragments at the MS2 level for comprehensive structural characterization. Here, we studied the electronic excitation dissociation (EED) behaviors of metal-adducted, permethylated glycans, and identified key spectral features that could facilitate both topology and linkage determinations. We developed an EED-based, nanoscale, reversed phase (RP)LC-MS/MS platform, and demonstrated its ability to achieve complete structural elucidation of up to five structural isomers in a single LC-MS/MS analysis. [Figure not available: see fulltext.
Storbeck, Karl-Heinz; Gilligan, Lorna; Jenkinson, Carl; Baranowski, Elizabeth S; Quanson, Jonathan L; Arlt, Wiebke; Taylor, Angela E
2018-05-15
Liquid chromatography tandem mass spectrometry (LC-MS/MS) assays are considered the reference standard for serum steroid hormone analyses, while full urinary steroid profiles are only achievable by gas chromatography (GC-MS). Both LC-MS/MS and GC-MS have well documented strengths and limitations. Recently, commercial ultra-high performance supercritical fluid chromatography-tandem mass spectrometry (UHPSFC-MS/MS) systems have been developed. These systems combine the resolution of GC with the high-throughput capabilities of UHPLC. Uptake of this new technology into research and clinical labs has been slow, possibly due to the perceived increase in complexity. Here we therefore present fundamental principles of UHPSFC-MS/MS and the likely applications for this technology in the clinical research setting, while commenting on potential hurdles based on our experience to date. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
Sel, Sabriye; Öztürk Er, Elif; Bakırdere, Sezgin
2017-12-01
A highly sensitive and simple diode-array high-performance liquid chromatography and liquid chromatography with quadrupole time-of-flight tandem mass spectrometry method was developed for the simultaneous determination of niacin and pyridoxine in pharmaceutical drugs, tap water, and wastewater samples. To determine the in vivo behavior of niacin and pyridoxine, analytes were subjected to simulated gastric conditions. The calibration plots of the diode-array high-performance liquid chromatography and liquid chromatography with quadrupole time-of-flight tandem mass spectrometry method showed good linearity over a wide concentration range with close to 1.0 correlation coefficients for both analytes. The limit of detection/limit of quantitation values for liquid chromatography quadrupole time-of-flight tandem mass spectrometry analysis were 1.98/6.59 and 1.3/4.4 μg/L for niacin and pyridoxine, respectively, while limit of detection/limit of quantitation values for niacin and pyridoxine in high-performance liquid chromatography analysis were 3.7/12.3 and 5.7/18.9 μg/L, respectively. Recovery studies were also performed to show the applicability of the developed methods, and percentage recovery values were found to be 90-105% in tap water and 94-97% in wastewater for both analytes. The method was also successfully applied for the qualitative and quantitative determination of niacin and pyridoxine in drug samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Fan, Sufang; Li, Qiang; Zhang, Xiaoguang; Cui, Xiaobin; Zhang, Dongsheng; Zhang, Yan
2015-05-01
A novel fully automated method based on dual column switching using turbulent flow chromatography followed by liquid chromatography with tandem mass spectrometry was developed for the determination of aflatoxin B1 , B2 , G1 , and G2 in corn powder, edible oil, peanut butter, and soy sauce samples. After ultrasound-assisted extraction, samples were directly injected to the chromatographic system and the analytes were concentrated into the clean-up loading column. Through purge switching, the analytes were transferred to the analytical column for subsequent detection by mass spectrometry. Different types of TurboFlow(TM) columns, transfer flow rate, transfer time were optimized. The limits of detection and quantification of this method ranged between 0.2-2.0 and 0.5-4.0 μg/kg for aflatoxins in different matrixes, respectively. Recoveries of aflatoxins were in range of 83-108.1% for all samples, matrix effects were in range of 34.1-104.7%. The developed method has been successfully applied in the analysis of aflatoxin B1 , B2 , G1 , and G2 in real samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
USDA-ARS?s Scientific Manuscript database
Traditional Chinese medicines (TCMs) have been widely used for the prevention and treatment of various diseases for thousands of years in China. Ultra Performance Liquid Chromatography (UHPLC) is a relatively new technique offering new possibilities in liquid chromatography. This paper reviews recen...
Book Chapter 18, titled Application in pesticide analysis: Liquid chromatography - A review of the state of science for biomarker discovery and identification, will be published in the book titled High Performance Liquid Chromatography in Pesticide Residue Analysis (Part of the C...
Weber, Berthold; Hartmann, Beate; Stöckigt, Detlef; Schreiber, Klaus; Roloff, Michael; Bertram, Heinz-Jürgen; Schmidt, Claus O
2006-01-25
Liquid chromatography/mass spectrometry and liquid chromatography/nuclear magnetic resonance techniques with ultraviolet/diode array detection were used as complementary analytical tools for the reliable identification of polymethoxylated flavones in residues from molecular distillation of cold-pressed peel oils of Citrus sinensis. After development of a liquid chromatographic separation procedure, the presence of several polymethoxy flavones such as sinensetin, nobiletin, tangeretin, quercetogetin, heptamethoxyflavone, and other derivatives was unambiguously confirmed. In addition, proceranone, an acetylated tetranortriterpenoid with limonoid structure, was identified for the first time in citrus.
Mixed Stationary Liquid Phases for Gas-Liquid Chromatography.
ERIC Educational Resources Information Center
Koury, Albert M.; Parcher, Jon F.
1979-01-01
Describes a laboratory technique for use in an undergraduate instrumental analysis course that, using the interpretation of window diagrams, prepares a mixed liquid phase column for gas-liquid chromatography. A detailed procedure is provided. (BT)
Gao, Meng; Wang, Yuesheng; Wei, Huizhen; Ouyang, Hui; He, Mingzhen; Zeng, Lianqing; Shen, Fengyun; Guo, Qiang; Rao, Yi
2014-06-01
A method was developed for the determination of amygdalin and its metabolite prunasin in rat plasma after intragastric administration of Maxing shigan decoction. The analytes were identified by ultra-high performance liquid chromatography-tandem quadrupole time of flight mass spectrometry and quantitatively determined by ultra-high performance liquid chromatography-tandem triple quadrupole mass spectrometry. After purified by liquid-liquid extraction, the qualitative analysis of amygdalin and prunasin in the plasma sample was performed on a Shim-pack XR-ODS III HPLC column (75 mm x 2.0 mm, 1.6 microm), using acetonitrile-0.1% (v/v) formic acid aqueous solution. The detection was performed on a Triple TOF 5600 quadrupole time of flight mass spectrometer. The quantitative analysis of amygdalin and prunasin in the plasma sample was performed by separation on an Agilent C18 HPLC column (50 mm x 2.1 mm, 1.7 microm), using acetonitrile-0.1% (v/v) formic acid aqueous solution. The detection was performed on an AB Q-TRAP 4500 triple quadrupole mass spectrometer utilizing electrospray ionization (ESI) interface operated in negative ion mode and multiple-reaction monitoring (MRM) mode. The qualitative analysis results showed that amygdalin and its metabolite prunasin were detected in the plasma sample. The quantitative analysis results showed that the linear range of amygdalin was 1.05-4 200 ng/mL with the correlation coefficient of 0.999 0 and the linear range of prunasin was 1.25-2 490 ng/mL with the correlation coefficient of 0.997 0. The method had a good precision with the relative standard deviations (RSDs) lower than 9.20% and the overall recoveries varied from 82.33% to 95.25%. The limits of detection (LODs) of amygdalin and prunasin were 0.50 ng/mL. With good reproducibility, the method is simple, fast and effective for the qualitative and quantitative analysis of the amygdalin and prunasin in plasma sample of rats which were administered by Maxing shigan decoction.
ERIC Educational Resources Information Center
Lochmuller, C. H.; And Others
1980-01-01
Presents an undergraduate analytical chemistry experiment that promotes an interpretation of the molecular aspects of solute partitioning, enhancing student understanding of separation science and liquid chromatography. (CS)
Eichhold, Thomas H; McCauley-Myers, David L; Khambe, Deepa A; Thompson, Gary A; Hoke, Steven H
2007-01-17
A method for the simultaneous determination of dextromethorphan (DEX), dextrorphan (DET), and guaifenesin (GG) in human plasma was developed, validated, and applied to determine plasma concentrations of these compounds in samples from six clinical pharmacokinetic (PK) studies. Semi-automated liquid handling systems were used to perform the majority of the sample manipulation including liquid/liquid extraction (LLE) of the analytes from human plasma. Stable-isotope-labeled analogues were utilized as internal standards (ISTDs) for each analyte to facilitate accurate and precise quantification. Extracts were analyzed using gradient liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). Use of semi-automated LLE with LC-MS/MS proved to be a very rugged and reliable approach for analysis of more than 6200 clinical study samples. The lower limit of quantification was validated at 0.010, 0.010, and 1.0 ng/mL of plasma for DEX, DET, and GG, respectively. Accuracy and precision of quality control (QC) samples for all three analytes met FDA Guidance criteria of +/-15% for average QC accuracy with coefficients of variation less than 15%. Data from the thorough evaluation of the method during development, validation, and application are presented to characterize selectivity, linearity, over-range sample analysis, accuracy, precision, autosampler carry-over, ruggedness, extraction efficiency, ionization suppression, and stability. Pharmacokinetic data are also provided to illustrate improvements in systemic drug and metabolite concentration-time profiles that were achieved by formulation optimization.
ERIC Educational Resources Information Center
O'Donnell, Mary E.; Musial, Beata A.; Bretz, Stacey Lowery; Danielson, Neil D.; Ca, Diep
2009-01-01
Liquid chromatography (LC) experiments for the undergraduate analytical laboratory course often illustrate the application of reversed-phase LC to solve a separation problem, but rarely compare LC retention mechanisms. In addition, a high-performance liquid chromatography instrument may be beyond what some small colleges can purchase. Solid-phase…
Da, Xu; Qian, Ling-Jia
2005-08-01
To establish a method for detection of plasma total homocysteine with HPLC. The chromatography analysis was carried out using a Symmetry Shield RP18. The mobile phase was sodium acetate (0.08 mol/L) and methanol (1%) and we utilized a HPLC system with fluorescence detection of plasma homocysteine derivatized from reaction with 7-fluorobenzo-2-oxa-1,3-diazole-4-sulphonate (SBD-F). The average recoveries were 95.8 - 100.8% and the relative standard deviations were 1.2-2.0%. The results showed it to be a rapid and accurate method for the determination of homocysteine level in plasma.
Palmer, Kevin B; LaFon, William; Burford, Mark D
2017-09-22
Current analytical methodology for iodopropynyl butylcarbamate (IPBC) analysis focuses on the use of liquid chromatography and mass spectrometer (LC-MS), but the high instrumentation and operator investment required has resulted in the need for a cost effective alternative methodology. Past publications investigating gas chromatography with electron capture detector (GC-ECD) for IPBC quantitation proved largely unsuccessful, likely due to the preservatives limited thermal stability. The use of pulsed injection techniques commonly used for trace analysis of thermally labile pharmaceutical compounds was successfully adapted for IPBC analysis and utilizes the selectivity of GC-ECD analysis. System optimization and sample preparation improvements resulted in substantial performance and reproducibility gains. Cosmetic formulations preserved with IPBC (50-100ppm) were solvated in toluene/isopropyl alcohol and quantified over the 0.3-1.3μg/ml calibration range. The methodology was robust (relative standard deviation 4%), accurate (98% recovery), and sensitive (limit of detection 0.25ng/ml) for use in routine testing of cosmetic formulation preservation. Copyright © 2017 Elsevier B.V. All rights reserved.
Recent advances in liquid-phase separations for clinical metabolomics.
Kohler, Isabelle; Giera, Martin
2017-01-01
Over the last decades, several technological improvements have been achieved in liquid-based separation techniques, notably, with the advent of fully porous sub-2 μm particles and superficially porous sub-3 μm particles, the comeback of supercritical fluid chromatography, and the development of alternative chromatographic modes such as hydrophilic interaction chromatography. Combined with mass spectrometry, these techniques have demonstrated their added value, substantially increasing separation efficiency, selectivity, and speed of analysis. These benefits are essential in modern clinical metabolomics typically involving the study of large-scale sample cohorts and the analysis of thousands of metabolites showing extensive differences in physicochemical properties. This review presents a brief overview of the recent developments in liquid-phase separation sciences in the context of clinical metabolomics, focusing on increased throughput as well as metabolite coverage. Relevant metabolomics applications highlighting the benefits of ultra-high performance liquid chromatography, core-shell technology, high-temperature liquid chromatography, capillary electrophoresis, supercritical fluid chromatography, and hydrophilic interaction chromatography are discussed. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Technical Reports Server (NTRS)
Carden, J. L.; Browner, R.
1982-01-01
The preparation and analysis of standardized waste samples for controlled ecological life support systems (CELSS) are considered. Analysis of samples from wet oxidation experiments, the development of ion chromatographic techniques utilizing conventional high pressure liquid chromatography (HPLC) equipment, and an investigation of techniques for interfacing an ion chromatograph (IC) with an inductively coupled plasma optical emission spectrometer (ICPOES) are discussed.
Reichel, W.L.; Kolbe, E.J.; Stafford, C.J.
1981-01-01
A procedure is described for determining fenvalerate and permethrin residues in grasshoppers and duck tissues. Samples are Soxhlet-extracted with hexane and cleaned up by gel permeation chromatography with an in-line alumina column. Samples are analyzed by gas-liquid chromatography with electron capture detection, and confirmed by gas-liquid chromatography-mass spectrometry. The average recovery from fortified tissues was 97%.
Advanced proteomic liquid chromatography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xie, Fang; Smith, Richard D.; Shen, Yufeng
2012-10-26
Liquid chromatography coupled with mass spectrometry is the predominant platform used to analyze proteomics samples consisting of large numbers of proteins and their proteolytic products (e.g., truncated polypeptides) and spanning a wide range of relative concentrations. This review provides an overview of advanced capillary liquid chromatography techniques and methodologies that greatly improve separation resolving power and proteomics analysis coverage, sensitivity, and throughput.
Dissolution of NTO, DNAN, and Insensitive Munitions Formulations and Their Fates in Soils
2014-09-01
3 2 Mass loss measured by high precision liquid chromatography (HPLC) versus measured mass loss by... Liquid Chromatography IM Insensitive Munitions IMX Insensitive Munitions eXplosive k First-Order Transformation Rate Constant kphoto First...Performance Liquid Chromatography U.S. EPA United States Environmental Protection Agency WMRD Weapons and Materials Research Directorate ERDC/CRREL
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-05
... was required for gas chromatography with mass selective detection (GC/MSD) but not for liquid... detection (LOD = 0.01) and a gas liquid chromatography (GLC) method with a flame photometric detection (LOD... quantification by high performance liquid chromatography with tandem mass spectrometric detection (HPLC/MS/MS...
Ionic liquid stationary phases for gas chromatography.
Poole, Colin F; Poole, Salwa K
2011-04-01
This article provides a summary of the development of ionic liquids as stationary phases for gas chromatography beginning with early work on packed columns that established details of the retention mechanism and established working methods to characterize selectivity differences compared with molecular stationary phases through the modern development of multi-centered cation and cross-linked ionic liquids for high-temperature applications in capillary gas chromatography. Since there are many reviews on ionic liquids dealing with all aspects of their chemical and physical properties, the emphasis in this article is placed on the role of gas chromatography played in the design of ionic liquids of low melting point, high thermal stability, high viscosity, and variable selectivity for separations. Ionic liquids provide unprecedented opportunities for extending the selectivity range and temperature-operating range of columns for gas chromatography, an area of separation science that has otherwise been almost stagnant for over a decade. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Lin, Che-Yi; Fuh, Ming-Ren; Huang, Shang-Da
2011-02-01
A method termed liquid-liquid-liquid microextraction (LLLME) was utilized to extract 4-t-butylphenol, 4-t-octylphenol, 4-n-nonylphenol, and bisphenol-A from water. The extracted target analytes were separated and quantified by high-performance liquid chromatography using a fluorescence detector. In LLLME, the donor phase (i.e. water sample) was made weakly acidic by adding monobasic potassium phosphate (KH(2) PO(4)); the organic phase adopted was 4-chlorotoluene; the acceptor phase (i.e. enriched extract) was 0.2 M tetraethylammonium hydroxide dissolved in ethylene glycol. This study solves a problem associated with the surface activity of long-chain alkylphenolate ions, permitting LLLME to extract long-chain alkylphenols. Experimental conditions such as acceptor phase composition, organic phase identity, acceptor phase volume, sample agitation, extraction time, and salt addition were optimized. The relative standard deviation (RSD, 2.0-5.8%), coefficient of determination (r(2) 0.9977-0.9999), and detection limit (0.017-0.0048 ng/mL) of the proposed method were achieved under the selected optimized conditions. The method was successfully applied to analyses of lake and tap water samples, and the relative recoveries of target analytes from the spiked lake and tap water samples were 92.8-106.3 and 93.6-105.6%, respectively. The results obtained with the proposed method confirm this microextraction technique to be reliable for the monitoring of alkylphenols and bisphenol-A in water samples. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
McEntire, John E.; Kuo, Kenneth C.; Smith, Mark E.; Stalling, David L.; Richens, Jack W.; Zumwalt, Robert W.; Gehrke, Charles W.; Papermaster, Ben W.
1989-01-01
A wide spectrum of modified nucleosides has been quantified by high-performance liquid chromatography in serum of 49 male lung cancer patients, 35 patients with other cancers, and 48 patients hospitalized for nonneoplastic diseases. Data for 29 modified nucleoside peaks were normalized to an internal standard and analyzed by discriminant analysis and stepwise discriminant analysis. A model based on peaks selected by a stepwise discriminant procedure correctly classified 79% of the cancer and 75% of the noncancer subjects. It also demonstrated 84% sensitivity and 79% specificity when comparing lung cancer to noncancer subjects, and 80% sensitivity and 55% specificity in comparing lung cancer to other cancers. The nucleoside peaks having the greatest influence on the models varied dependent on the subgroups compared, confirming the importance of quantifying a wide array of nucleosides. These data support and expand previous studies which reported the utility of measuring modified nucleoside levels in serum and show that precise measurement of an array of 29 modified nucleosides in serum by high-performance liquid chromatography with UV scanning with subsequent data modeling may provide a clinically useful approach to patient classification in diagnosis and subsequent therapeutic monitoring.
Carnes, Stephanie; O'Brien, Stacey; Szewczak, Angelica; Tremeau-Cayel, Lauriane; Rowe, Walter F; McCord, Bruce; Lurie, Ira S
2017-09-01
A comparison of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography for the separation of synthetic cathinones has been conducted. Nine different mixtures of bath salts were analyzed in this study. The three different chromatographic techniques were examined using a general set of controlled synthetic cathinones as well as a variety of other synthetic cathinones that exist as positional isomers. Overall 35 different synthetic cathinones were analyzed. A variety of column types and chromatographic modes were examined for developing each separation. For the ultra high performance supercritical fluid chromatography separations, analyses were performed using a series of Torus and Trefoil columns with either ammonium formate or ammonium hydroxide as additives, and methanol, ethanol or isopropanol organic solvents as modifiers. Ultra high performance liquid chromatographic separations were performed in both reversed phase and hydrophilic interaction chromatographic modes using SPP C18 and SPP HILIC columns. Gas chromatography separations were performed using an Elite-5MS capillary column. The orthogonality of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography was examined using principal component analysis. For the best overall separation of synthetic cathinones, the use of ultra high performance supercritical fluid chromatography in combination with gas chromatography is recommended. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Jandera, Pavel; Hájek, Tomáš
2018-01-01
Hydrophilic interaction liquid chromatography on polar columns in aqueous-organic mobile phases has become increasingly popular for the separation of many biologically important compounds in chemical, environmental, food, toxicological, and other samples. In spite of many new applications appearing in literature, the retention mechanism is still controversial. This review addresses recent progress in understanding of the retention models in hydrophilic interaction liquid chromatography. The main attention is focused on the role of water, both adsorbed by the column and contained in the bulk mobile phase. Further, the theoretical retention models in the isocratic and gradient elution modes are discussed. The dual hydrophilic interaction liquid chromatography reversed-phase retention mechanism on polar columns is treated in detail, especially with respect to the practical use in one- and two-dimensional liquid chromatography separations. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Xu, Qing-Fang; Han, Jian-Guo; Yu, Zhu; Yue, Wen-Bin
2010-05-01
The near infrared reflectance spectroscopy technique (NIRS) has been explored at many fields such as agriculture, food, chemical, medicine, and so on, due to its rapid, effective, non-destructive, and on-line characteristics. Fungi invasion in forage materials during processing and storage would generate mycotoxins, which were harmful for people and animal through food chains. The determination of mycotoxins included the overelaborated pretreatments such as milling, extracting, chromatography and subsequent process such as enzyme linked immunosorbent assay, high performance liquid chromatography, and thin layer chromatography. The authors hope that high precision and low detection limit spectrum instrument, and software technology and calibration model of mycotoxins determination, will fast measure accurately the quality and quantity of mycotoxins, which will provide basis for reasonable process and utilization of forage and promote the application of NIRS in the safety livestock product.
An automated method for the determination of carbendazim in water that combines high-performance immunoaffinity chromatography (HPIAC), high-performance liquid chromatography (HPLC) in the reversed-phase mode, and detection by either UV-Vis diode array detector (DAD) spectroscopy...
Advanced proteomic liquid chromatography
Xie, Fang; Smith, Richard D.; Shen, Yufeng
2012-01-01
Liquid chromatography coupled with mass spectrometry is the predominant platform used to analyze proteomics samples consisting of large numbers of proteins and their proteolytic products (e.g., truncated polypeptides) and spanning a wide range of relative concentrations. This review provides an overview of advanced capillary liquid chromatography techniques and methodologies that greatly improve separation resolving power and proteomics analysis coverage, sensitivity, and throughput. PMID:22840822
Development and Applications of Liquid Sample Desorption Electrospray Ionization Mass Spectrometry
NASA Astrophysics Data System (ADS)
Zheng, Qiuling; Chen, Hao
2016-06-01
Desorption electrospray ionization mass spectrometry (DESI-MS) is a recent advance in the field of analytical chemistry. This review surveys the development of liquid sample DESI-MS (LS-DESI-MS), a variant form of DESI-MS that focuses on fast analysis of liquid samples, and its novel analy-tical applications in bioanalysis, proteomics, and reaction kinetics. Due to the capability of directly ionizing liquid samples, liquid sample DESI (LS-DESI) has been successfully used to couple MS with various analytical techniques, such as microfluidics, microextraction, electrochemistry, and chromatography. This review also covers these hyphenated techniques. In addition, several closely related ionization methods, including transmission mode DESI, thermally assisted DESI, and continuous flow-extractive DESI, are briefly discussed. The capabilities of LS-DESI extend and/or complement the utilities of traditional DESI and electrospray ionization and will find extensive and valuable analytical application in the future.
Abudayeh, Zead Helmi Mahmoud; Al Azzam, Khaldun Mohammad; Naddaf, Ahmad; Karpiuk, Uliana Vladimirovna; Kislichenko, Viktoria Sergeevna
2015-11-01
To separate and quantify four major saponins in the extracts of the skin and the endosperm of seeds of horse chestnut (Aesculus hippocastanum L.) using ultrasonic solvent extraction followed by a high performance liquid chromatography-diode array detector (HPLC-DAD) with positive confirmation by thin layer chromatography (TLC). The saponins: escin Ia, escin Ib, isoescin Ia and isoescin Ib were extracted using ultrasonic extraction method. The optimized extraction conditions were: 70% methanol as extraction solvent, 80 °C as extraction temperature, and the extraction time was achieved in 4 hours. The HPLC conditions used: Zorbax SB-ODS-(150 mm × 2.1 mm, 3 μm) column, acetonitrile and 0.10% phosphoric acid solution (39:61 v/v) as mobile phase, flow rate was 0.5 mL min(-1) at 210 nm and 230 nm detection. The injection volume was 10 μL, and the separation was carried out isothermally at 30 °C in a heated chamber. The results indicated that the developed HPLC method is simple, sensitive and reliable. Moreover, the content of escins in seeds decreased by more than 30% in endosperm and by more than 40% in skin upon storage for two years. This assay can be readily utilized as a quality control method for horse chestnut and other related medicinal plants.
Appel, David I.; Brinda, Bryan; Markowitz, John S.; Newcorn, Jeffrey H.; Zhu, Hao-Jie
2012-01-01
A simple, rapid and sensitive method for quantification of atomoxetine by liquid chromatography- tandem mass spectrometry (LC-MS/MS) was developed. This assay represents the first LC-MS/MS quantification method for atomoxetine utilizing electrospray ionization. Deuterated atomoxetine (d3-atomoxetine) was adopted as the internal standard. Direct protein precipitation was utilized for sample preparation. This method was validated for both human plasma and in vitro cellular samples. The lower limit of quantification was 3 ng/ml and 10 nM for human plasma and cellular samples, respectively. The calibration curves were linear within the ranges of 3 ng/ml to 900 ng/ml and 10 nM to 10 μM for human plasma and cellular samples, respectively (r2 > 0.999). The intra- and inter-day assay accuracy and precision were evaluated using quality control samples at 3 different concentrations in both human plasma and cellular lysate. Sample run stability, assay selectivity, matrix effect, and recovery were also successfully demonstrated. The present assay is superior to previously published LC-MS and LC-MS/MS methods in terms of sensitivity or the simplicity of sample preparation. This assay is applicable to the analysis of atomoxetine in both human plasma and in vitro cellular samples. PMID:22275222
Woldegebriel, Michael; Derks, Eduard
2017-01-17
In this work, a novel probabilistic untargeted feature detection algorithm for liquid chromatography coupled to high-resolution mass spectrometry (LC-HRMS) using artificial neural network (ANN) is presented. The feature detection process is approached as a pattern recognition problem, and thus, ANN was utilized as an efficient feature recognition tool. Unlike most existing feature detection algorithms, with this approach, any suspected chromatographic profile (i.e., shape of a peak) can easily be incorporated by training the network, avoiding the need to perform computationally expensive regression methods with specific mathematical models. In addition, with this method, we have shown that the high-resolution raw data can be fully utilized without applying any arbitrary thresholds or data reduction, therefore improving the sensitivity of the method for compound identification purposes. Furthermore, opposed to existing deterministic (binary) approaches, this method rather estimates the probability of a feature being present/absent at a given point of interest, thus giving chance for all data points to be propagated down the data analysis pipeline, weighed with their probability. The algorithm was tested with data sets generated from spiked samples in forensic and food safety context and has shown promising results by detecting features for all compounds in a computationally reasonable time.
Móricz, Ágnes M; Krüzselyi, Dániel; Alberti, Ágnes; Darcsi, András; Horváth, Györgyi; Csontos, Péter; Béni, Szabolcs; Ott, Péter G
2017-11-17
The antibacterial profiling of Onopordum acanthium L. leaf extract and subsequent targeted identification of active compounds is demonstrated. Thin-layer chromatography (TLC) and off-line overpressured layer chromatography (OPLC) coupled with direct bioautography were utilized for investigation of the extract against eight bacterial strains including two plant and three human pathogens and a soil, a marine and a probiotic human gut bacteria. Antibacterial fractions obtaining infusion-transfusion OPLC were transferred to HPLC-MS/MS analysis that resulted in the characterization of three active compounds and two of them were identified as, linoleic and linolenic acid. OPLC method was adopted to preparative-scale flash chromatography for the isolation of the third active compound, which was identified after a further semi-preparative HPLC purification as the germacranolide sesquiterpene lactone onopordopicrin. Pure onopordopicrin exhibited antibacterial activity that was specified as minimal inhibitory concentration in the liquid phase as well. Copyright © 2017 Elsevier B.V. All rights reserved.
Chen, Bifan; Lin, Ziqing; Alpert, Andrew J; Fu, Cexiong; Zhang, Qunying; Pritts, Wayne A; Ge, Ying
2018-06-19
Therapeutic monoclonal antibodies (mAbs) are an important class of drugs for a wide spectrum of human diseases. Liquid chromatography (LC) coupled to mass spectrometry (MS) is one of the techniques in the forefront for comprehensive characterization of analytical attributes of mAbs. Among various protein chromatography modes, hydrophobic interaction chromatography (HIC) is a popular offline nondenaturing separation technique utilized to purify and analyze mAbs, typically with the use of non-MS-compatible mobile phases. Herein we demonstrate for the first time, the application of direct HIC-MS and HIC-tandem MS (MS/MS) with electron capture dissociation (ECD) for analyzing intact mAbs on quadrupole-time-of-flight (Q-TOF) and Fourier transform ion cyclotron resonance (FTICR) mass spectrometers, respectively. Our method allows for rapid determination of relative hydrophobicity, intact masses, and glycosylation profiles of mAbs as well as sequence and structural characterization of the complementarity-determining regions in an online configuration.
Qiao, Lizhen; Shi, Xianzhe; Lu, Xin; Xu, Guowang
2015-05-29
Two tricationic ionic liquids were prepared and then bonded onto the surface of supporting silica materials through "thiol-ene" click chemistry as new stationary phases for high-performance liquid chromatography. The obtained columns of tricationic ionic liquids were evaluated respectively in the reversed-phase liquid chromatography (RPLC) mode and hydrophilic interaction liquid chromatography (HILIC) mode, and possess ideal column efficiency of 80,000 plates/m in the RPLC mode with naphthalene as the test solute. The tricationic ionic liquid stationary phases exhibit good hydrophobic and shape selectivity to hydrophobic compounds, and RPLC retention behavior with multiple interactions. In the HILIC mode, the retention and selectivity were evaluated through the efficient separation of nucleosides and bases as well as flavonoids, and the typical HILIC retention behavior was demonstrated by investigating retention changes of hydrophilic solutes with water volume fraction in mobile phase. The results show that the tricationic ionic liquid columns possess great prospect for applications in analysis of hydrophobic and hydrophilic samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Wang, Nani; Wang, Xuping; Zhang, Yang; Zhang, Qiaoyan; Xu, Pingcui; Xin, Hailiang; Wu, Renjie; Shou, Dan; Qin, Luping
2018-05-30
Osthole is a derivative of coumnarin, which has been used to treat several diseases, including osteoporosis. To investigate the metabolite profile of osthole in osteoporosis rats was utilized to understand its underlying mechanisms of its anti-osteoporosis effect. In this study, plasma samples were collected from normal and osteoporosis rats after oral administration of osthole and analyzed to identify the metabolites of osthole by high performance liquid chromatography quadrupole time-of-flight mass spectrometry. By comparing the molecular weight and MS fragmentation of the metabolites with those of parent drug and reference standards, a total of 36 metabolites in plasma were identified. Demethylation, hydroxylation, hydroxymethylene loss and reduction, and subsequent glucuronidation, methylation and sulfation were the major metabolic pathways of osthole in both normal and osteoporosis rats. A specific hydration metabolic pathway was found in osteoporosis rats. These results provided a meaningful basis for studying the underlying mechanism of the anti-osteoporosis effect of osthole. Copyright © 2018 Elsevier B.V. All rights reserved.
Arning, Erland; Bottiglieri, Teodoro
2016-01-01
We describe a simple stable isotope dilution method for accurate and precise measurement of cerebrospinal fluid (CSF) 5-methyltetrahydrofolate (5-MTHF) as a clinical diagnostic test. 5-MTHF is the main biologically active form of folic acid and is involved in regulation of homocysteine and DNA synthesis. Measurement of 5-MTHF in CSF provides diagnostic information regarding diseases affecting folate metabolism within the central nervous system, in particular inborn errors of folate metabolism. Determination of 5-MTHF in CSF (50 μL) was performed utilizing high performance liquid chromatography coupled with electrospray positive ionization tandem mass spectrometry (HPLC-ESI-MS/MS). 5-MTHF in CSF is determined by a 1:2 dilution with internal standard (5-MTHF-(13)C5) and injected directly onto the HPLC-ESI-MS/MS system. Each assay is quantified using a five-point standard curve (25-400 nM) and has an analytical measurement range of 3-1000 nM.
Du, Wei; Sun, Min; Guo, Pengqi; Chang, Chun; Fu, Qiang
2018-09-01
Nowadays, the abuse of antibiotics in aquaculture has generated considerable problems for food safety. Therefore, it is imperative to develop a simple and selective method for monitoring illegal use of antibiotics in aquatic products. In this study, a method combined molecularly imprinted membranes (MIMs) extraction and liquid chromatography was developed for the selective analysis of cloxacillin from shrimp samples. The MIMs was synthesized by UV photopolymerization, and characterized by scanning electron microscope, Fourier transform infrared spectra, thermo-gravimetric analysis and swelling test. The results showed that the MIMs exhibited excellent permselectivity, high adsorption capacity and fast adsorption rate for cloxacillin. Finally, the method was utilized to determine cloxacillin from shrimp samples, with good accuracies and acceptable relative standard deviation values for precision. The proposed method was a promising alternative for selective analysis of cloxacillin in shrimp samples, due to the easy-operation and excellent selectivity. Copyright © 2018. Published by Elsevier Ltd.
Comparison of non-volatile umami components in chicken soup and chicken enzymatic hydrolysate.
Kong, Yan; Yang, Xiao; Ding, Qi; Zhang, Yu-Yu; Sun, Bao-Guo; Chen, Hai-Tao; Sun, Ying
2017-12-01
Umami taste is an important part to the taste of chicken. To isolate and identify non-volatile umami compounds, fractions from chicken soup and hydrolysate were prepared and analyzed. Amino acids were analyzed by amino acid analyzer. Organic acids and nucleotides were determined by ultra-performance liquid chromatography. Separation procedures utilizing ultrafiltration, Sephadex G-15 and reversed-phase high-performance liquid chromatography were used to isolate umami taste peptides. Combined with sensory evaluation and LC-Q-TOF-MS, the amino acid sequences of 12 oligopeptides were determined. The amount of taste compounds was higher in chicken enzymatic hydrolysate than that of chicken soup. Eight oligopeptides from chicken enzymatic hydrolysate were identified, including Ala-Asp, Ala-Met, His-Ser, Val-Glu, Ala-Glu, Asp-Ala-Gly, Glu-Asp and Ala-Glu-Ala. Four oligopeptides from chicken soup were identified, including Val-Thr, Ala-His, Ala-Phe and Thr-Glu. Copyright © 2017 Elsevier Ltd. All rights reserved.
Classification of explosives transformation products in plant tissue
DOE Office of Scientific and Technical Information (OSTI.GOV)
Larson, S.L.; Jones, R.P.; Escalon, L.
Explosives contamination in surface or groundwater used for the irrigation of food crops and phytoremediation of explosives-contaminated soil or water using plant-assisted biodegradation have brought about concerns as to the fate of explosives in plants. Liquid scintillation counting, high-performance liquid chromatography, and gel permeation chromatography were utilized to characterize explosives (hexahydro-1,3,5-trinitro-1,3,5-triazine and trinitrotoluene) and their metabolites in plant tissues obtained from three separate studies. Analyzing tissues of yellow nutsedge (Cyperus esculentus), corn (Zea mays), lettuce (Lacuta sativa), tomato (Lyopersicum esculentum), radish (Raphanus sativus), and parrot feather (Myriophyllum aquaticum) from three studies where exposure to explosives at nontoxic levels occurred showedmore » that extensive transformation of the explosive contaminant occurred, variations were noted in uptake and transformation between terrestrial and aquatic plants, the products had significantly higher polarity and water solubility than the parent compounds, and the molecular sizes of the transformation products were significantly greater than those of the parent compounds.« less
Hoh, Carmen S L; Boocock, David J; Marczylo, Timothy H; Brown, V A; Cai, Hong; Steward, William P; Berry, David P; Gescher, Andreas J
2007-04-04
Silibinin has recently received attention as a potential cancer chemopreventive agent because of its antiproliferative and anticarcinogenic effects. A simple and specific reversed-phase high-performance liquid chromatography method was developed and validated for the quantitation of silibinin in human plasma. Sample preparation involved simple protein precipitation, and separation was achieved on a Waters Atlantis C18 column with flow rate of 1.0 mL/min at 40 degrees C and UV detection at 290 nm. Silibinin was detected as two peaks corresponding to trans-diastereoisomers. The peak area was linear over the investigated concentration range (0-5000 ng/mL). The limits of detection were 2 and 1 ng/mL for the two diastereoisomers (d1 and d2), with a recovery of 53-58%. This method was utilized to detect silibinin in plasma of colorectal patients after 7 days of treatment with silipide (silibinin formulated with phosphatidyl choline).
NASA Technical Reports Server (NTRS)
Valentine, J. L.; Bryant, P. J.
1975-01-01
Analysis of human breath is a nonintrusive method to monitor both endogenous and exogenous chemicals found in the body. Several technologies were investigated and developed which are applicable to monitoring some organic molecules important in both physiological and pathological states. Two methods were developed for enriching the organic molecules exhaled in the breath of humans. One device is based on a respiratory face mask fitted with a polyethylene foam wafer; while the other device is a cryogenic trap utilizing an organic solvent. Using laboratory workers as controls, two organic molecules which occurred in the enriched breath of all subjects were tentatively identified as lactic acid and contisol. Both of these substances occurred in breath in sufficient amounts that the conventional method of gas-liquid chromatography was adequate for detection and quantification. To detect and quantitate trace amounts of chemicals in breath, another type of technology was developed in which analysis was conducted using high pressure liquid chromatography and mass spectrometry.
Peterson, R. E.; Grove, M. D.
1983-01-01
A method was developed for the production and purification of xanthomegnin from Penicillium viridicatum (NRRL 6430) cultured on rice at 15°C for 29 days. Liquid-liquid extraction followed by high-pressure liquid chromatography afforded 440 mg of crystalline xanthomegnin per kg of rice. PMID:6881966
Sun, Wanyang; Tong, Ling; Miao, Jingzhuo; Huang, Jingyi; Li, Dongxiang; Li, Yunfei; Xiao, Hongting; Sun, Henry; Bi, Kaishun
2016-01-29
Salvia miltiorrhiza (SM) is one of the most widely used Traditional Chinese Medicine. Active constituents of SM mainly contain hydrophilic phenolic acids (PAs) and lipophilic tanshinones. However, due to the existing of multiple ester bonds and unsaturated bonds in the structures, PAs have numerous chemical conversion products. Many of them are so low-abundant that hard to be separated using conventional methods. In this study, an off-line two-dimensional liquid chromatography (2D-LC) method was developed to separate PAs in SM and its related preparations. In the first dimension, samples were fractionated by hydrophilic interaction chromatography (HILIC) (Acchrom×Amide, 4.6×250mm, 5μm) mainly based on the hydrogen bonding effects. The fractions were then separated on reversed-phase liquid chromatography (RP-LC) (Acquity HSS T3, 2.1×50mm, 1.7μm) according to hydrophobicity. For the selective identification of PAs, diode array detector (DAD) and electrospray ionization tandem ion trap time-of-flight mass spectrometry (ESI-IT-TOF-MS) were employed. Practical and effective peak capacities of all the samples were greater than 2046 and 1130, respectively, with the orthogonalities ranged from 69.7% to 92.8%, which indicated the high efficiency and versatility of this method. By utilizing the data post-processing techniques, including mass defect filter, neutral loss filter and product ion filter, a total of 265 compounds comprising 196 potentially new PAs were tentatively characterized. Twelve kinds of derivatives, mainly including glycosylated compounds, O-alkylated compounds, condensed compounds and hydrolyzed compounds, constituted the novelty of the newly identified PAs. The HILIC×RP-LC/TOF-MS system expanded our understanding on PAs of S. miltiorrhiza and its related preparations, which could also benefit the separation and characterization of polar constituents in complicated herbal extracts. Copyright © 2016. Published by Elsevier B.V.
Baglai, Anna; Gargano, Andrea F G; Jordens, Jan; Mengerink, Ynze; Honing, Maarten; van der Wal, Sjoerd; Schoenmakers, Peter J
2017-12-29
Recent advancements in separation science have resulted in the commercialization of multidimensional separation systems that provide higher peak capacities and, hence, enable a more-detailed characterization of complex mixtures. In particular, two powerful analytical tools are increasingly used by analytical scientists, namely online comprehensive two-dimensional liquid chromatography (LC×LC, having a second-dimension separation in the liquid phase) and liquid chromatography-ion mobility-spectrometry (LC-IMS, second dimension separation in the gas phase). The goal of the current study was a general assessment of the liquid-chromatography-trapped-ion-mobility-mass spectrometry (LC-TIMS-MS) and comprehensive two-dimensional liquid chromatography-mass spectrometry (LC×LC-MS) platforms for untargeted lipid mapping in human plasma. For the first time trapped-ion-mobility spectrometry (TIMS) was employed for the separation of the major lipid classes and ion-mobility-derived collision-cross-section values were determined for a number of lipid standards. The general effects of a number of influencing parameters have been inspected and possible directions for improvements are discussed. We aimed to provide a general indication and practical guidelines for the analyst to choose an efficient multidimensional separation platform according to the particular requirements of the application. Analysis time, orthogonality, peak capacity, and an indicative measure for the resolving power are discussed as main characteristics for multidimensional separation systems. Copyright © 2017 Elsevier B.V. All rights reserved.
The methods of formaldehyde emission testing of engine: A review
NASA Astrophysics Data System (ADS)
Zhang, Chunhui; Geng, Peng; Cao, Erming; Wei, Lijiang
2015-12-01
A number of measurements have been provided to detect formaldehyde in the atmosphere, but there are no clear unified standards in engine exhaust. Nowadays, formaldehyde, an unregulated emission from methanol engine, has been attracting increasing attention by researchers. This paper presents the detection techniques for formaldehyde emitted from the engines applied in recent market, introducing the approaches in terms of unregulated emission tests of formaldehyde, which involved gas chromatography, liquid chromatography, chromatography-mass spectrometry, chromatography-spectrum, Fourier infrared spectroscopy and spectrophotometry. The author also introduces the comparison regarding to the advantages of the existing detection techniques based on the principle, to compare with engine exhaust sampling method, the treatment in advance of detection, obtaining approaches accessing to the qualitative and quantitative analysis of chromatograms or spectra. The accuratest result obtained was chromatography though it cannot be used continuously. It also can be utilized to develop high requirements of emissions and other regulations. Fourier infrared spectroscopy has the advantage of continuous detection for a variety of unregulated emissions and can be applied to the bench in variable condition. However, its accuracy is not as good as chromatography. As the conclusion, a detection technique is chosen based on different requirements.
Pose-Juan, Eva; Rial-Otero, Raquel; Martínez-Carballo, Elena; López-Periago, Eugenio; Simal-Gándara, Jesús
2009-07-01
Foliar runoff is one of the most important processes affecting off-target movement of fungicides. In this way, Ridomil Gold Plus and Ridomil Gold MZ are two types of wettable powder technical formulations which contain metalaxyl and they are used for such a purpose. A method for quantitative determination of metalaxyl in pesticide formulas has been developed, validated, and subsequently applied to Ridomil Gold Plus and Ridomil Gold MZ. The method employs liquid-liquid extraction followed by liquid chromatography coupled with UV detection (LC-UV), using gas chromatography coupled with mass spectrometry as confirmation technique and to carry out a screening of organic adjuvants of these two selected pesticide formulas. Metalaxyl of 26.5 and 41 g/kg was detected in Ridomil Gold Plus and Ridomil Gold MZ, close to the manufacture specified level of 25 and 40 g/kg, respectively. Activator and utility adjuvants were detected in these two wettable powder technical formulations. Only methyl-ester-based surfactants were found within the group of nonionic surfactants, but the long-term fates of most adjuvants in soils and elsewhere in the environment are largely unknown, partially because of the lack of long-term monitoring data.
Motono, Tomohiro; Nagai, Takashi; Kitagawa, Shinya; Ohtani, Hajime
2015-07-01
Low-temperature high-performance liquid chromatography, in which a loop injector, column, and detection cell were refrigerated at -35ºC, using liquid carbon dioxide as the mobile phase was developed. Small organic compounds (polyaromatic hydrocarbons, alkylbenzenes, and quinones) were separated by low-temperature high-performance liquid chromatography at temperatures from -35 to -5ºC. The combination of liquid carbon dioxide mobile phase with an octadecyl-silica (C18 ) column provided reversed phase mode separation, and a bare silica-gel column resulted in normal phase mode separation. In both the cases, nonlinear behavior at approximately -15ºC was found in the relationship between the temperature and the retention factors of the analytes (van't Hoff plots). In contrast to general trends in high-performance liquid chromatography, the decrease in temperature enhanced the separation efficiency of both the columns. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Suzuki, Shigeru
2014-01-01
The techniques and measurement methods developed in the Environmental Survey and Monitoring of Chemicals by Japan’s Ministry of the Environment, as well as a large amount of knowledge archived in the survey, have led to the advancement of environmental analysis. Recently, technologies such as non-target liquid chromatography/high resolution mass spectrometry and liquid chromatography with micro bore column have further developed the field. Here, the general strategy of a method developed for the liquid chromatography/mass spectrometry (LC/MS) analysis of environmental chemicals with a brief description is presented. Also, a non-target analysis for the identification of environmental pollutants using a provisional fragment database and “MsMsFilter,” an elemental composition elucidation tool, is presented. This analytical method is shown to be highly effective in the identification of a model chemical, the pesticide Bendiocarb. Our improved micro-liquid chromatography injection system showed substantially enhanced sensitivity to perfluoroalkyl substances, with peak areas 32–71 times larger than those observed in conventional LC/MS. PMID:26819891
Fredriksson, Mattias J; Petersson, Patrik; Axelsson, Bengt-Olof; Bylund, Dan
2011-10-17
A strategy for rapid optimization of liquid chromatography column temperature and gradient shape is presented. The optimization as such is based on the well established retention and peak width models implemented in software like e.g. DryLab and LC simulator. The novel part of the strategy is a highly automated processing algorithm for detection and tracking of chromatographic peaks in noisy liquid chromatography-mass spectrometry (LC-MS) data. The strategy is presented and visualized by the optimization of the separation of two degradants present in ultraviolet (UV) exposed fluocinolone acetonide. It should be stressed, however, that it can be utilized for LC-MS analysis of any sample and application where several runs are conducted on the same sample. In the application presented, 30 components that were difficult or impossible to detect in the UV data could be automatically detected and tracked in the MS data by using the proposed strategy. The number of correctly tracked components was above 95%. Using the parameters from the reconstructed data sets to the model gave good agreement between predicted and observed retention times at optimal conditions. The area of the smallest tracked component was estimated to 0.08% compared to the main component, a level relevant for the characterization of impurities in the pharmaceutical industry. Copyright © 2011 Elsevier B.V. All rights reserved.
Studzińska, Sylwia; Mounicou, Sandra; Szpunar, Joanna; Łobiński, Ryszard; Buszewski, Bogusław
2015-01-15
This text presents a novel method for the separation and detection of phosphorothioate oligonucleotides with the use of ion pair ultra high performance liquid chromatography coupled with inductively coupled plasma mass spectrometry The research showed that hexafluoroisopropanol/triethylamine based mobile phases may be successfully used when liquid chromatography is coupled with such elemental detection. However, the concentration of both HFIP and TEA influences the final result. The lower concentration of HFIP, the lower the background in ICP-MS and the greater the sensitivity. The method applied for the analysis of serum samples was based on high resolution inductively coupled plasma mass spectrometry. Utilization of this method allows determination of fifty times lower quantity of phosphorothioate oligonucleotides than in the case of quadrupole mass analyzer. Monitoring of (31)P may be used to quantify these compounds at the level of 80 μg L(-1), while simultaneous determination of sulfur is very useful for qualitative analysis. Moreover, the results presented in this paper demonstrate the practical applicability of coupling LC with ICP-MS in determining phosphorothioate oligonucleotides and their metabolites in serum within 7 min with a very good sensitivity. The method was linear in the concentration range between 0.2 and 3 mg L(-1). The limit of detection was in the range of 0.07 and 0.13 mg L(-1). Accuracy varied with concentration, but was in the range of 3%. Copyright © 2014 Elsevier B.V. All rights reserved.
Wang, Jing; Shi, Dongfang; Zheng, Meizhu; Ma, Bing; Cui, Jing; Liu, Chunming; Liu, Chengyu
2017-11-01
Natural products have become one of the most important resources for discovering novel xanthine oxidase inhibitors, which are commonly employed in the treatment of hyperuricemia and gout. However, to date, few reports exist regarding the use of monoterpene glycosides as xanthine oxidase inhibitors. Thus, we herein report the use of ultrafiltration coupled with liquid chromatography in the screening of monoterpene glycoside xanthine oxidase inhibitors from the extract of Paeonia lactiflora (P. lactiflora), and both high-performance counter-current chromatography and medium-pressure liquid chromatography were employed to separate the main constituents. Furthermore, the xanthine oxidase inhibitory activities and the mechanisms of inhibition of the isolated compounds were evaluated using a multi-mode microplate reader by Molecular Devices. As a result, three monoterpene glycosides were separated by combined high-performance counter-current chromatography and medium-pressure liquid chromatography in purities of 90.4, 98.0, and 86.3%, as determined by liquid chromatography. These three compounds were identified as albiflorin, paeoniflorin, and 1-O-β-ᴅ-glucopyranosyl-8-O-benzoylpaeonisuffrone by electrospray ionization tandem mass spectrometry, and albiflorin and paeoniflorin were screened as potential xanthine oxidase inhibitors by ultrafiltration with liquid chromatography. The evaluation results of xanthine oxidase inhibitory activity corresponded with the screening results, as only albiflorin and paeoniflorin exhibited xanthine oxidase inhibitory activity. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Tao, Lingyan; Zhang, Qing; Wu, Yongjiang; Liu, Xuesong
2016-12-01
In this study, a fast and effective high-performance liquid chromatography method was developed to obtain a fingerprint chromatogram and quantitative analysis simultaneously of four indexes including gallic acid, chlorogenic acid, albiflorin and paeoniflorin of the traditional Chinese medicine Moluodan Concentrated Pill. The method was performed by using a Waters X-bridge C 18 reversed phase column on an Agilent 1200S high-performance liquid chromatography system coupled with diode array detection. The mobile phase of the high-performance liquid chromatography method was composed of 20 mmol/L phosphate solution and acetonitrile with a 1 mL/min eluent velocity, under a detection temperature of 30°C and a UV detection wavelength of 254 nm. After the methodology validation, 16 batches of Moluodan Concentrated Pill were analyzed by this high-performance liquid chromatography method and both qualitative and quantitative evaluation results were achieved by similarity analysis, principal component analysis and hierarchical cluster analysis. The results of these three chemometrics were in good agreement and all indicated that batch 10 and batch 16 showed significant differences with the other 14 batches. This suggested that the developed high-performance liquid chromatography method could be applied in the quality evaluation of Moluodan Concentrated Pill. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Wang, Yu-Qing; Tang, Xu; Li, Jia-Fu; Wu, Yun-Long; Sun, Yu-Ying; Fang, Mei-Juan; Wu, Zhen; Wang, Xiu-Min; Qiu, Ying-Kun
2017-10-13
A novel on-line comprehensive two-dimensional liquid chromatography (2D-LC) method by coupling mixed-mode gel liquid chromatography (MMG-LC) with reversed phase liquid chromatography (RPLC) was developed. A mixture of 17 reference compounds was used to study the separation mechanism. A crude water extract of Flos Carthami was applied to evaluate the performance of the novel 2D-LC system. In the first dimension, the extract was eluted with a gradient of water/methanol over a cross-linked dextran gel Sephadex LH-20 column. Meanwhile, the advantages of size exclusion, reversed phase partition and adsorption separation mechanism were exploited before further on-line reversed phase purification on the second dimension. This novel on-line mixed-mode Sephadex LH-20×RPLC method provided higher peak resolution, sample processing ability (2.5mg) and better orthogonality (72.9%) versus RPLC×RPLC and hydrophilic interaction liquid chromatography (HILIC)×RPLC. To the best of our knowledge, this is the first report of a mixed-mode Sephadex LH-20×RPLC separation method with successful applications in on-line mode, which might be beneficial for harvesting targets from complicated medicinal plants. Copyright © 2017 Elsevier B.V. All rights reserved.
Comprehensive two-dimensional liquid chromatography for polyphenol analysis in foodstuffs.
Cacciola, Francesco; Farnetti, Sara; Dugo, Paola; Marriott, Philip John; Mondello, Luigi
2017-01-01
Polyphenols are a class of plant secondary metabolites that are recently drawing a special interest because of their broad spectrum of pharmacological effects. As they are characterized by an enormous structural variability, the identification of these molecules in food samples is a difficult task, and sometimes having only a limited number of commercially available reference materials is not of great help. One-dimensional liquid chromatography is the most widely applied analytical approach for their analysis. In particular, the hyphenation of liquid chromatography to mass spectrometry has come to play an influential role by allowing relatively fast tentative identification and accurate quantification of polyphenolic compounds at trace levels in vegetable media. However, when dealing with very complex real-world food samples, a single separation system often does not provide sufficient resolving power for attaining rewarding results. Comprehensive two-dimensional liquid chromatography is a technique of great analytical impact, since it offers much higher peak capacities than separations in a single dimension. In the present review, we describe applications in the field of comprehensive two-dimensional liquid chromatography for polyphenol analysis in real-world food samples. Comprehensive two-dimensional liquid chromatography applications to nonfood matrices fall outside the scope of the current report and will not be discussed. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Durairaju Nisshanthini, S; Teresa Infanta S, Antony K; Raja, Duraisamy Senthil; Natarajan, Karuppannan; Palaniswamy, M; Angayarkanni, Jayaraman
2015-04-01
Soil and water samples were collected from various regions of SIPCOT and nearby Vanappadi Lake, Ranipet, Tamilnadu, India. Based on their colony morphology and their stability during subculturing, 72 bacteria were isolated, of which 14 isolates were actinomycetes. Preliminary selection was carried out to exploit the ability of the microorganisms to utilize sodium cyanate as nitrogen source. Those organisms that were able to utilize cyanate were subjected to secondary screening viz., utilization of sodium cyanide as the nitrogen source. The oxygenolytic cleavage of cyanide is dependent on cyanide monooxygenase which obligately requires pterin cofactor for its activity. Based on this, the organisms capable of utilizing sodium cyanide were tested for the presence of pterin. Thin layer chromatography (TLC) of the cell extracts using n-butanol: 5 N glacial acetic acid (4:1) revealed that 10 out of 12 organisms that were able to utilize cyanide had the pterin-related blue fluorescent compound in the cell extract. The cell extracts of these 10 organisms were subjected to high performance thin layer chromatography (HPTLC) for further confirmation using a pterin standard. Based on the incubation period, cell biomass yield, peak height and area, strain VPW3 was selected and was identified as Bacillus subtilis. The Rf value of the cell extract was 0.73 which was consistent with the 0.74 Rf value of the pterin standard when scanned at 254 nm. The compound was extracted and purified by preparative High Performance Liquid Chromatography (HPLC). Characterization of the compound was performed by ultraviolet spectrum, fluorescence spectrum, Electrospray Ionization-Mass Spectrometry (ESI-MS), and Nuclear Magnetic Resonance spectroscopy (NMR). The compound is proposed to be 6-propionyl pterin (2-amino-6-propionyl-3H-pteridin-4-one).
Spill-Detector-and-Shutoff Device
NASA Technical Reports Server (NTRS)
Jarvis, M. R.; Fulton, D. S.
1985-01-01
Overflow in liquid chromatography systems rapidly detected and stopped. Spill-detector-and-shutoff device incorporated into liquid-chromatography system. When liquid from output nozzle spills on liquid sensor, device automatically shuts off pump and releases solenoid to pinch off flow in tube. Device uses common type of alarm circuit reset manually before normal operation resumes.
Zapata, Félix; de la Ossa, Mª Ángeles Fernández; Gilchrist, Elizabeth; Barron, Leon; García-Ruiz, Carmen
2016-12-01
Concerning the dreadful global threat of terrorist attacks, the detection of explosive residues in biological traces and marks is a current need in both forensics and homeland security. This study examines the potential of Raman microscopy in comparison to liquid chromatography (ion chromatography (IC) and reversed-phase high performance liquid chromatography (RP-HPLC)) to detect, identify and quantify residues in human handmarks of explosives and energetic salts commonly used to manufacture Improvised Explosive Devices (IEDs) including dynamite, ammonium nitrate, single- and double-smokeless gunpowders and black powder. Dynamite, ammonium nitrate and black powder were detected through the identification of the energetic salts by Raman spectroscopy, their respective anions by IC, and organic components by RP-HPLC. Smokeless gunpowders were not detected, either by Raman spectroscopy or the two liquid chromatography techniques. Several aspects of handprint collection, sample treatment and a critical comparison of the identification of compounds by both techniques are discussed. Raman microscopy and liquid chromatography were shown to be complementary to one another offering more comprehensive information for trace explosives analysis. Copyright © 2016 Elsevier B.V. All rights reserved.
[Development of methods for determining acrylamide in food products by gas-liquid chromatography].
Bessonov, V V; Malinkin, A D; Perederiaev, O I; Bogachuk, M N; Volkovich, S V; Medvedev, Iu V
2011-01-01
The method of determination of acrylamide in various food (milk powder, potato chips, instant coffee) by gas-liquid chromatography after pre-bromination was developed. Studies have shown the possibility of using bromination of acrylamide to give it the necessary properties for better extraction, purification and detection. Also revealed the possibility of qualitative and quantitative determine a acrylamide in food by gas-liquid chromatography with detection by electron capture detector.
2013-05-28
span of 1-250 ng DDT. Furthermore, laboratory and field experiments utilizing this method confirmed that significant DDT concentration differences ... different between the two sample introduction methods when comparing the same DDT mass which may be due to differences in the precision of split...degradation of DDT was significantly different between the liquid and TD methods (t-test; p < 0.001). For TD analyses the relative percent
Beug, M W; Bigwood, J
1981-03-27
Rapid quantification of psilocybin and psilocin in extracts of wild mushrooms is accomplished by reversed-phase high-performance liquid chromatography with paired-ion reagents. Nine solvent systems and three solid supports are evaluated for their efficiency in separating psilocybin, psilocin and other components of crude mushroom extracts by thin-layer chromatography.
Wang, Jiafei; Bai, Ligai; Wei, Zhen; Qin, Junxiao; Ma, Yamin; Liu, Haiyan
2015-06-01
An ionic liquid was incorporated into the porous polymer monoliths to afford stationary phases with enhanced chromatographic performance for small molecules in reversed-phase high-performance liquid chromatography. The effect of the ionic liquid in the polymerization mixture on the performance of the monoliths was studied in detail. While monoliths without ionic liquid exhibited poor resolution and low efficiency, the addition of ionic liquid to the polymerization mixture provides highly increased resolution and high efficiency. The chromatographic performances of the monoliths were demonstrated by the separations of various small molecules including aromatic hydrocarbons, isomers, and homologues using a binary polar mobile phase. The present column efficiency reached 27 000 plates/m, which showed that the ionic liquid monoliths are alternative stationary phases in the separation of small molecules by high-performance liquid chromatography. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
USDA-ARS?s Scientific Manuscript database
A method for the highly sensitive determination of 2-, 3- and 4- nitrophenols was developed using reverse-phase high-performance liquid chromatography (RP-HPLC) with a UV photodiode array detector. Using a reverse-phase column and 40% aqueous acetonitrile as an eluent (i.e. isocratic elution), the i...
Wang, Jing; Pan, Hefang; Liu, Zhengzheng; Ge, Fei
2009-03-20
A novel method has been developed for the determination of alkylphenols in soil by ultra-high-pressure liquid chromatography employing small particle sizes, combined with tandem mass spectrometry. Soil samples were extracted with pressurized liquid extraction (PLE) and then cleaned with solid-phase extraction (SPE). The extracts were separated on C18 column (1.7 microm, 50 mm x 2.1mm) with a gradient elution and a mobile phase consisting of water and acetonitrile, and then detected by an electrospray ionization tandem mass spectrometry in negative ion mode with multiple reaction monitoring (MRM). Compared with traditional liquid chromatography, it took ultra-high-pressure liquid chromatography much less time to analyze alkylphenols. Additionally, the ultra-high-pressure liquid chromatography/tandem mass spectrometry method produces satisfactory reliability, sensitivity, and accuracy. The average recoveries of the three target analytes were 74.0-103.4%, with the RSD<15%. The calibration curves for alkylphenols were linear within the range of 0.01-0.4 microg/ml, with the correlation coefficients greater than 0.99. When 10 g soil sample was used for analysis, the limits of quantification (LOQs) of the three alkylphenols were all 1.0 microg/kg.
Loconto, Paul R; Isenga, David; O'Keefe, Michael; Knottnerus, Mark
2008-01-01
Polybrominated diphenyl ethers (PBDEs) are isolated and recovered with acceptable percent recoveries from human serum via liquid-liquid extraction and column chromatographic cleanup and fractionation with quantitation using capillary gas chromatography-mass spectrometry with electron capture negative ion and selected ion monitoring. PBDEs are found in unspiked serum. An alternative sample preparation approach is developed using sheep serum that utilizes a formic acid pre-treatment followed by reversed-phase solid-phase disk extraction and normal-phase solid-phase cleanup using acidified silica gel that yields>50% recoveries. When these percent recoveries are combined with a minimized phase ratio for human serum and very low instrument detection limits, method detection limits below 500 parts-per-trillion are realized.
APPLICATION OF A SPRAY DEPOSITION METHOD FOR REVERSED PHASE LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY
Four coal gasification wastewater samples were analyzed for nonvolatile and polar organics by liquid chromatography-mass spectrometry (LC/MS). Samples were separated on a reverse phase liquid chromatographic column using an aqueous solvent as the eluant. A special spray depositio...
Bertani-Dziedzic, L M; Krstulovic, A M; Dziedzic, S W; Gitlow, S E; Cerqueira, S
1981-02-19
A sensitive and specific direct analysis of urinary normetanephrine (NMN) and metanephrine (MN) was achieved utilizing reversed-phase high performance liquid chromatography and electrochemical detection. Individual specimens from "control" subjects and those with pheochromocytoma were hydrolyzed and the metanephrines separated from other urinary constituents by elution with ammonia from a Dowex CG-50 resin. Chromatographic peaks were identified by retention behavior, co-chromatography with reference compounds, ratio of responses at various oxidation potentials and stopped-flow UV spectra of the collected fractions. The NMN and MN content for the control subjects was between 0.086 and 0.21 (mean - 0.14) microgram/mg creatinine and 0.012 and 0.092 (mean = 0.039) microgram/mg creatinine, respectively. The values for subjects with pheochromocytoma varied from 1.5 to 27.5 (mean = 9.9) microgram/mg creatinine for NMN and 0.10 to 1.60 (mean = 0.86) microgram/mg creatine for MN. The patient with ganglioneuroma had an NMN of 4.1 and an MN of 0.80 microgram/mg creatinine. While this method permits discrimination between those patients with pheochromocytoma and the overwhelming majority of hypertensive patients, it may ultimately be further extended to separate normal subjects from those with more subtle derangements in catecholamine metabolism.
Zou, Wei; She, Jianwen; Tolstikov, Vladimir V.
2013-01-01
Current available biomarkers lack sensitivity and/or specificity for early detection of cancer. To address this challenge, a robust and complete workflow for metabolic profiling and data mining is described in details. Three independent and complementary analytical techniques for metabolic profiling are applied: hydrophilic interaction liquid chromatography (HILIC–LC), reversed-phase liquid chromatography (RP–LC), and gas chromatography (GC). All three techniques are coupled to a mass spectrometer (MS) in the full scan acquisition mode, and both unsupervised and supervised methods are used for data mining. The univariate and multivariate feature selection are used to determine subsets of potentially discriminative predictors. These predictors are further identified by obtaining accurate masses and isotopic ratios using selected ion monitoring (SIM) and data-dependent MS/MS and/or accurate mass MSn ion tree scans utilizing high resolution MS. A list combining all of the identified potential biomarkers generated from different platforms and algorithms is used for pathway analysis. Such a workflow combining comprehensive metabolic profiling and advanced data mining techniques may provide a powerful approach for metabolic pathway analysis and biomarker discovery in cancer research. Two case studies with previous published data are adapted and included in the context to elucidate the application of the workflow. PMID:24958150
Liquid Chromatography at Critical Conditions: Balancing size exclusion and adsorption in nanopores
NASA Astrophysics Data System (ADS)
Abdulahad, Asem; Amos, Jeffrey; Ryu, Chang
2009-03-01
Liquid chromatography at critical condition (LCCC) is a measure to identify thermodynamic conditions, in which polymers elute independently of molar mass during high performance liquid chromatography. Under these critical conditions the entropic exclusions that dominate size exclusion chromatography (SEC) and the enthalpic adsorption that governs adsorption-based interaction chromatography (IC) are said to negate one another resulting in simultaneous elution of the polymer of different molecular weights. Using multiple C18-bonded silica columns with different average nanopore sizes (from 5 nm to 30 nm), we will study the LCCC conditions of PS in methylene chloride/acetonitrile solvent mixture at different temperature. In addition, we will show that the separation of polystyrene can be fine tuned using a refined temperature gradient interaction chromatography (TGIC) that employs multiple columns of varying pore size in sequence.
Counter-current motion in counter-current chromatography.
Ito, Yoichiro
2014-12-12
After the CCC2012 meeting, I have received an e-mail regarding the terminology of "Countercurrent Chromatography". It stated that the term "Countercurrent" is a misnomer, because its stationary phase is motionless in the column and that the method should be renamed as liquid-liquid separations or centrifugal separations. However, it was found that these names are already used for various other techniques as found via Google search. The term "Countercurrent Chromatography" was originally made after two preparative methods of Countercurrent distribution and liquid Chromatography, both having no countercurrent motion in the column. However, it is surprising to find that this F1 hybrid method "Countercurrent Chromatography" can clearly exhibit countercurrent motion within the separation column in both hydrodynamic and hydrostatic equilibrium systems. This justifies that "Countercurrent Chromatography" is a proper term for this chromatographic method. Published by Elsevier B.V.
Abudayeh, Zead Helmi Mahmoud; Al Azzam, Khaldun Mohammad; Naddaf, Ahmad; Karpiuk, Uliana Vladimirovna; Kislichenko, Viktoria Sergeevna
2015-01-01
Purpose: To separate and quantify four major saponins in the extracts of the skin and the endosperm of seeds of horse chestnut (Aesculus hippocastanum L.) using ultrasonic solvent extraction followed by a high performance liquid chromatography-diode array detector (HPLC-DAD) with positive confirmation by thin layer chromatography (TLC). Methods: The saponins: escin Ia, escin Ib, isoescin Ia and isoescin Ib were extracted using ultrasonic extraction method. The optimized extraction conditions were: 70% methanol as extraction solvent, 80 °C as extraction temperature, and the extraction time was achieved in 4 hours. The HPLC conditions used: Zorbax SB-ODS-(150 mm × 2.1 mm, 3 μm) column, acetonitrile and 0.10% phosphoric acid solution (39:61 v/v) as mobile phase, flow rate was 0.5 mL min−1 at 210 nm and 230 nm detection. The injection volume was 10 μL, and the separation was carried out isothermally at 30 °C in a heated chamber. Results: The results indicated that the developed HPLC method is simple, sensitive and reliable. Moreover, the content of escins in seeds decreased by more than 30% in endosperm and by more than 40% in skin upon storage for two years. Conclusion: This assay can be readily utilized as a quality control method for horse chestnut and other related medicinal plants. PMID:26819933
Muhammad, Saqib; Han, Shengli; Xie, Xiaoyu; Wang, Sicen; Aziz, Muhammad Majid
2017-01-01
Cell membrane chromatography is a simple, specific, and time-saving technique for studying drug-receptor interactions, screening of active components from complex mixtures, and quality control of traditional Chinese medicines. However, the short column life, low sensitivity, low column efficiency (so cannot resolve satisfactorily mixture of compounds), low peak capacity, and inefficient in structure identification were bottleneck in its application. Combinations of cell membrane chromatography with multidimensional chromatography such as two-dimensional liquid chromatography and high sensitivity detectors like mass have significantly reduced many of the above-mentioned shortcomings. This paper provides an overview of the current advances in online two-dimensional-based cell membrane chromatography for screening target components from traditional Chinese medicines with particular emphasis on the instrumentation, preparation of cell membrane stationary phase, advantages, and disadvantages compared to alternative approaches. The last section of the review summarizes the applications of the online two-dimensional high-performance liquid chromatography based cell membrane chromatography reported since its emergence to date (2010-June 2016). © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Analysis of selected herbicide metabolites in surface and ground water of the United States
Scribner, E.A.; Thurman, E.M.; Zimmerman, L.R.
2000-01-01
One of the primary goals of the US Geological Survey (USGS) Laboratory in Lawrence, Kansas, is to develop analytical methods for the analysis of herbicide metabolites in surface and ground water that are vital to the study of herbicide fate and degradation pathways in the environment. Methods to measure metabolite concentrations from three major classes of herbicides - triazine, chloroacetanilide and phenyl-urea - have been developed. Methods for triazine metabolite detection cover nine compounds: six compounds are detected by gas chromatography/mass spectrometry; one is detected by high-performance liquid chromatography with diode-array detection; and eight are detected by liquid chromatography/mass spectrometry. Two metabolites of the chloroacetanilide herbicides - ethane sulfonic acid and oxanilic acid - are detected by high-performance liquid chromatography with diode-array detection and liquid chromatography/mass spectrometry. Alachlor ethane sulfonic acid also has been detected by solid-phase extraction and enzyme-linked immunosorbent assay. Six phenylurea metabolites are all detected by liquid chromatography/mass spectrometry; four of the six metabolites also are detected by gas chromatography/mass spectrometry. Additionally, surveys of herbicides and their metabolites in surface water, ground water, lakes, reservoirs, and rainfall have been conducted through the USGS laboratory in Lawrence. These surveys have been useful in determining herbicide and metabolite occurrence and temporal distribution and have shown that metabolites may be useful in evaluation of non-point-source contamination. Copyright (C) 2000 Elsevier Science B.V.
Young, Joshua E; Pan, Zhongli; Teh, Hui Ean; Menon, Veena; Modereger, Brent; Pesek, Joseph J; Matyska, Maria T; Dao, Lan; Takeoka, Gary
2017-04-01
The peels of different pomegranate cultivars (Molla Nepes, Parfianka, Purple Heart, Wonderful and Vkunsyi) were compared in terms of phenolic composition and total phenolics. Analyses were performed on two silica hydride based stationary phases: phenyl and undecanoic acid columns. Quantitation was accomplished by developing a liquid chromatography with mass spectrometry approach for separating different phenolic analytes, initially in the form of reference standards and then with pomegranate extracts. The high-performance liquid chromatography columns used in the separations had the ability to retain a wide polarity range of phenolic analytes, as well as offering beneficial secondary selectivity mechanisms for resolving the isobaric compounds, catechin and epicatechin. The Vkunsyi peel extract had the highest concentration of phenolics (as determined by liquid chromatography with mass spectrometry) and was the only cultivar to contain the important compound punicalagin. The liquid chromatography with mass spectrometry data were compared to the standard total phenolics content as determined by using the Folin-Ciocalteu assay. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Šmigovec Ljubič, Tina; Pahovnik, David; Žigon, Majda; Žagar, Ema
2012-01-01
The separation of a mixture of three poly(styrene-block-t-butyl methacrylate) copolymers (PS-b-PtBMA), consisting of polystyrene (PS) blocks of similar length and t-butyl methacrylate (PtBMA) blocks of different lengths, was performed using various chromatographic techniques, that is, a gradient liquid chromatography on reversed-phase (C18 and C8) and normal-phase columns, a liquid chromatography under critical conditions for polystyrene as well as a fully automated two-dimensional liquid chromatography that separates block copolymers by chemical composition in the first dimension and by molar mass in the second dimension. The results show that a partial separation of the mixture of PS-b-PtBMA copolymers can be achieved only by gradient liquid chromatography on reversed-phase columns. The coelution of the two block copolymers is ascribed to a much shorter PtBMA block length, compared to the PS block, as well as a small difference in the length of the PtBMA block in two of these copolymers, which was confirmed by SEC-MALS and NMR spectroscopy. PMID:22489207
Li, Jia-Fu; Yan, Xia; Wu, Yun-Long; Fang, Mei-Juan; Wu, Zhen; Qiu, Ying-Kun
2017-04-15
An analytical two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography (2D NPLC × RPLC) system was constructed with a newly developed thermal evaporation assisted adsorption (TEAA) interface. This novel TEAA interface with heating temperature above solvent boiling point allowed fast removal of organic NPLC solvent and successfully solved the solvent incompatibility problem between NPLC and RPLC. The system achieved rapid on-line solvent exchange between the two dimensions within a short modulation time of 190 s and was applied in the analysis of an extract from the skin of Bufo bufo gargarizans. This is the first time to realize the on-line comprehensive analysis of a moderate polar natural product by coupling NPLC with reversed phase ultra-high performance liquid chromatography (UHPLC). To be highlighted, with the TEAA interface, the 2D NPLC × RPLC system provided excellent resolution and orthogonality (75.2%), when compared with that of 2D RPLC × RPLC. Copyright © 2017 Elsevier B.V. All rights reserved.
Instrument platforms for nano liquid chromatography.
Šesták, Jozef; Moravcová, Dana; Kahle, Vladislav
2015-11-20
The history of liquid chromatography started more than a century ago and miniaturization and automation are two leading trends in this field. Nanocolumn liquid chromatography (nano LC) and largely synonymous capillary liquid chromatography (capillary LC) are the most recent results of this process where miniaturization of column dimensions and sorbent particle size play crucial role. Very interesting results achieved in the research of extremely miniaturized LC columns at the end of the last century lacked distinctive raison d'être and only advances in mass spectrometry brought a real breakthrough. Configuration of nano LC-electrospray ionization mass spectrometry (LC-ESI-MS) has become a basic tool in bioanalytical chemistry, especially in proteomics. This review discusses and summarizes past and current trends in the realization of nano liquid chromatography (nano LC) platforms. Special attention is given to the mobile phase delivery under nanoflow rates (isocratic, gradient) and sample injection to the nanocolumn. Available detection techniques applied in nano LC separations are also briefly discussed. We followed up the key themes from the original scientific reports over gradual improvements up to the contemporary commercial solutions. Copyright © 2015 Elsevier B.V. All rights reserved.
Ono, Toshirou; Usami, Atsushi; Nakaya, Satoshi; Maeba, Keisuke; Yonejima, Yasunori; Toyoda, Masanori; Ikeda, Atsushi; Miyazawa, Mitsuo
2015-01-01
Enterococcus faecalis is one of the major lactic acid bacterium (LAB) species colonizing the intestines of animals and humans. The characteristic odor of the volatile oils obtained from both the liquid medium after incubation (MAI) and liquid medium before incubation (MBI) in the cultivation process of E. faecalis was investigated to determine the utility of the liquid medium. In total, fifty-six and thirty-two compounds were detected in the volatile oils from the MAI (MAI oil) and MBI (MBI oil), respectively. The principle components of MAI oil were 2,5-dimethylpyrazine (19.3%), phenylacetaldehyde (19.3%), and phenylethyl alcohol (9.3%). The aroma extract dilution analysis (AEDA) method was performed using gas chromatography-olfactometry (GC-O). The total number of aroma-active compounds identified in the volatile oil from MBI and MAI was thirteen compounds; in particular, 5-methyl-2-furanmethanol, phenylacetaldehyde, and phenylethyl alcohol were the most primary aroma-active compounds in MAI oil. These results imply that the industrial cultivation medium after incubation of E. faecalis may be utilized as a source of volatile oils.
Blechta, Vratislav; Kurfürst, Milan; Sýkora, Jan; Schraml, Jan
2007-03-23
LC-NMR utilizing (1)H and (29)Si NMR spectroscopy is ideally suited for the analysis of silicones. It is shown that reversed phase gradient LC-NMR surpasses standard gel permeation chromatography (GPC) and diffusion ordered spectroscopy (DOSY) in the analysis of model hydride terminated polydimethylsiloxane. (1)H and (29)Si NMR in the stopped-flow arrangement leads to full identification of the components. Concentration gradient introduces a dependence of the (29)Si shifts on solvent composition, this dependence can be substantially reduced by a proposed method of referencing. It is shown that the ADEQUATE version of powerful but insensitive 2D INADEQUATE experiment can be used for complete line assignment.
Wagner, Brian M.; Schuster, Stephanie A.; Boyes, Barry E.; Shields, Taylor J.; Miles, William L.; Haynes, Mark J.; Moran, Robert E.; Kirkland, Joseph J.; Schure, Mark R.
2017-01-01
To facilitate mass transport and column efficiency, solutes must have free access to particle pores to facilitate interactions with the stationary phase. To ensure this feature, particles should be used for HPLC separations which have pores sufficiently large to accommodate the solute without restricted diffusion. This paper describes the design and properties of superficially porous (also called Fused-Core®, core shell or porous shell) particles with very large (1000 Å) pores specifically developed for separating very large biomolecules and polymers. Separations of DNA fragments, monoclonal antibodies, large proteins and large polystyrene standards are used to illustrate the utility of these particles for efficient, high-resolution applications. PMID:28213987
Wagner, Brian M; Schuster, Stephanie A; Boyes, Barry E; Shields, Taylor J; Miles, William L; Haynes, Mark J; Moran, Robert E; Kirkland, Joseph J; Schure, Mark R
2017-03-17
To facilitate mass transport and column efficiency, solutes must have free access to particle pores to facilitate interactions with the stationary phase. To ensure this feature, particles should be used for HPLC separations which have pores sufficiently large to accommodate the solute without restricted diffusion. This paper describes the design and properties of superficially porous (also called Fused-Core ® , core shell or porous shell) particles with very large (1000Å) pores specifically developed for separating very large biomolecules and polymers. Separations of DNA fragments, monoclonal antibodies, large proteins and large polystyrene standards are used to illustrate the utility of these particles for efficient, high-resolution applications. Copyright © 2017 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Bindis, Michael P.; Bretz, Stacey Lowery; Danielson, Neil D.
2011-01-01
The high-performance liquid chromatography (HPLC) experiment, most often done in the undergraduate analytical instrumentation laboratory course, generally illustrates reversed-phase chromatography using a commercial C[subscript]18 silica column. To avoid the expense of periodic column replacement and introduce a choice of columns with different…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-24
... for plant commodities) are both gas liquid chromatography (GLC) methods with electron capture... analytical methodology using liquid chromatography/mass spectrometry/mass spectrometry (LC/MS/MS) detection...-aminopropane]) using gas chromatography (GC) have been submitted to the EPA. In addition, a new validated...
Wang, Xiaohong; Liang, Yong; Zhu, Licai; Xie, Huichun; Li, Hang; He, Junting; Pan, Man; Zhang, Tianyou; Ito, Yoichiro
2009-01-01
Combined with medium-pressure liquid chromatography (MPLC) and preparative high-performance liquid chromatography (perp-HPLC), high-speed countercurrent chromatography (HSCCC) was applied for separation and purification of flavone C-glycosides from the crude extract of leaves of Ficus microcarpae L. f. HSCCC separation was performed on a two-phase solvent system composed of methyl tert- butyl ether - ethyl acetate – 1-butanol – acetonitrile – 0.1% aqueous trifluoroacetic acid at a volume ratio of 1:3:1:1:5. Partially resolved peak fractions from HSCCC separation were further purified by preparative HPLC. Four well-separated compounds were obtained and their purities were determined by HPLC. The purities of these peaks were 97.28%, 97.20%, 92.23%, and 98.40%.. These peaks were characterized by ESI-MSn. According to the reference, they were identified as orientin (peak I), isovitexin-3″-O-glucopyranoside (peak II), isovitexin (peak III), and vitexin (peak IV), yielded 1.2 mg, 4.5 mg, 3.3 mg, and 1.8 mg, respectively. PMID:20190866
ERIC Educational Resources Information Center
Owens, Janel E.; Zimmerman, Laura B.; Gardner, Michael A.; Lowe, Luis E.
2016-01-01
Analysis of whiskey samples prepared by a green microextraction technique, dispersive liquid-liquid microextraction (DLLME), before analysis by a qualitative gas chromatography-mass spectrometry (GC/MS) method, is described as a laboratory experiment for an upper division instrumental methods of analysis laboratory course. Here, aroma compounds in…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Owens, J; Hok, S; Alcaraz, A
Tetramethylenedisulfotetramine, commonly known as tetramine, is a highly neurotoxic rodenticide (human oral LD{sub 50} = 0.1 mg/kg) used in hundreds of deliberate food poisoning events in China. Here we describe a method for quantitation of tetramine spiked into beverages, including milk, juice, tea, cola, and water and cleaned up by C8 solid phase extraction and liquid-liquid extraction. Quantitation by high performance liquid chromatography tandem mass spectrometry (LC/MS/MS) was based upon fragmentation of m/z 347 to m/z 268. The method was validated by gas chromatography mass spectrometry (GC/MS) operated in SIM mode for ions m/z 212, 240, and 360. The limitmore » of quantitation was 0.10 {micro}g/mL by LC/MS/MS versus 0.15 {micro}g/mL for GC/MS. Fortifications of the beverages at 2.5 {micro}g/mL and 0.25 {micro}g/mL were recovered ranging from 73-128% by liquid-liquid extraction for GC/MS analysis, 13-96% by SPE and 10-101% by liquid-liquid extraction for LC/MS/MS analysis.« less
Shih, Hou-Kuang; Shu, Ting-Yun; Ponnusamy, Vinoth Kumar; Jen, Jen-Fon
2015-01-07
In this study, a novel fatty-acid-based in-tube dispersive liquid-liquid microextraction (FA-IT-DLLME) technique is proposed for the first time and is developed as a simple, rapid and eco-friendly sample extraction method for the determination of alkylphenols in aqueous samples using high-performance liquid chromatography-ultraviolet detection (HPLC-UV). In this extraction method, medium-chain saturated fatty acids were investigated as a pH-dependent phase because they acted as either anionic surfactants or neutral extraction solvents based on the acid-base reaction caused solely by the adjustment of the pH of the solution. A specially designed home-made glass extraction tube with a built-in scaled capillary tube was utilized as the phase-separation device for the FA-IT-DLLME to collect and measure the separated extractant phase for analysis. Nonylphenol (NP) and 4-tert-octylphenol (4-tOP) were chosen as model analytes. The parameters influencing the FA-IT-DLLME were thoroughly investigated and optimized. Under the optimal conditions, the detector responses of NP and 4-tOP were linear in the concentration ranges of 5-4000 μg L(-1), with correlation coefficients of 0.9990 and 0.9996 for NP and 4-tOP, respectively. The limits of detection based on a signal-to-noise ratio of 3 were 0.7 and 0.5 μg L(-1), and the enrichment factors were 195 and 143 for NP and 4-tOP, respectively. The applicability of the developed method was demonstrated for the analysis of alkylphenols in environmental wastewater samples, and the recoveries ranged from 92.9 to 107.1%. The extraction process required less than 4 min and utilized only acids, alkalis, and fatty acids to achieve the extraction. The results demonstrated that the presented FA-IT-DLLME approach is highly cost-effective, simple, rapid and environmentally friendly in its sample preparation. Copyright © 2014 Elsevier B.V. All rights reserved.
2007-06-01
T ACanadaY Approved for PublicR Distribution Uln& Liquid Chromatography Electrospray Ionization Mass Spectrometric ( LC -ESI- MS) and Desorption...consumer products with chemical warfare agents or other toxic chemicals. Liquid chromatography electrospray ionization mass spectrometry ( LC -ESI-MS) and...house LC -ESI-MS and LC -ESI-MS/MS methods were evaluated for the determination of chemical warfare agents in spiked bottled water samples. The
Zonta, F; Stancher, B
1985-07-19
A high-performance liquid chromatographic method for determining phylloquinone (vitamin K1) in soy bean oils is described. Resolution of vitamin K1 from interfering peaks of the matrix was obtained after enzymatic digestion, extraction and liquid-solid chromatography on alumina. An isocratic reversed-phase chromatography with UV detection was used in the final stage. The quantitation was carried out by the standard addition method, and the recovery of the whole procedure was 88.2%.
Method 8321B describes procedures for preparation and analysis of solid, aqueous liquid, drinking water and wipe samples using high performance liquid chromatography and mass spectrometry for extractable non-volatile compounds.
Separation of anionic oligosaccharides by high-performance liquid chromatography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Green, E.D.; Baenziger, J.U.
1986-10-01
The authors have developed methods for rapid fractionation of anionic oligosaccharides containing sulfate and/or sialic acid moieties by high-performance liquid chromatography (HPLC). Ion-exchange HPLC on amine-bearing columns (Micropak AX-10 and AX-5) at pH 4.0 is utilized to separate anionic oligosaccharides bearing zero, one, two, three, or four charges, independent of the identity of the anionic moieties (sulfate and/or sialic acid). Ion-exchange HPLC at pH 1.7 allows separation of neutral, mono-, di-, and tetrasialylated, monosulfated, and disulfated oligosaccharides. Oligosaccharides containing three sialic acid residues and those bearing one each of sulfate and sialic acid, however, coelute at pH 1.7. Since themore » latter two oligosaccharide species separate at pH 4.0, analysis at pH 4.0 followed by analysis at pH 1.7 can be utilized to completely fractionate complex mixtures of sulfated and sialylated oligosaccharides. Ion-suppression amine adsorption HPLC has previously been shown to separate anionic oligosaccharides on the basis of net carbohydrate content (size). In this study they demonstrate the utility of ion-suppression amine adsorption HPLC for resolving sialylated oligosaccharide isomers which differ only in the linkages of sialic acid residues (..cap alpha..2,3 vs ..cap alpha..2,6) and/or location of ..cap alpha..2,3- and ..cap alpha..2,6-linked sialic acid moieties on the peripheral branches of oligosaccharides. These two methods can be used in tandem to separate oligosaccharides, both analytically and preparatively, based on their number, types, and linkages of anionic moieties.« less
Zoccali, Mariosimone; Barp, Laura; Beccaria, Marco; Sciarrone, Danilo; Purcaro, Giorgia; Mondello, Luigi
2016-02-01
Mineral oils, which are mainly composed of saturated hydrocarbons and aromatic hydrocarbons, are widespread food contaminants. Liquid chromatography coupled to gas chromatography with flame ionization detection represents the method of choice to determine these two families. However, despite the high selectivity of this technique, the presence of olefins (particularly squalene and its isomers) in some samples as in olive oils, does not allow the correct quantification of the mineral oil aromatic hydrocarbons fraction, requiring additional off-line tools to eliminate them. In the present research, a novel on-line liquid chromatography coupled to gas chromatography method is described for the determination of hydrocarbon contamination in edible oils. Two different liquid chromatography columns, namely a silica one (to retain the bulk of the matrix) and a silver-ion one (which better retains the olefins), were coupled in series to obtain the mineral oil aromatic hydrocarbons hump free of interfering peaks. Furthermore, the use of a simultaneous dual detection, flame ionization detector and triple quadrupole mass spectrometer allowed us not only to quantify the mineral oil contamination, but also to evaluate the presence of specific markers (i.e. hopanes) to confirm the petrogenic origin of the contamination. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Zhao, Bingqiang; Huang, Yanjun; Chen, Qiulan; Chen, Qizhao; Miao, Hui; Zhu, Shuang; Zeng, Changqing
2018-03-01
Uncaria is a multi-source herb and its species identification has become a bottleneck in quality control. To study the identification method of different Uncaria species herbs through HPLC-MS coupled with rDNA Internal Transcribed Spacer (rDNA ITS) sequence, both plant morphological traits and molecular identification were used to determine the species of every collected Uncaria herb. The genetic analysis of different Uncaria species was performed using their rDNA ITS sequence as a molecular marker. Meanwhile, the phylogenetic relationships of 22 samples from six Uncaria species were divided and classified clearly. By optimizing the chromatographic conditions, a practical HPLC method to differentiate various varieties of Uncaria herbs was set up based on a set of characteristic components across each species. A high-performance liquid chromatography-photodiode array detector tandem ion trap and time of flight mass spectrometry technique combined with reference substances was utilized to derive 21 characteristic compounds containing six groups of six Uncaria species in China. Thus, this study provides a feasible method to solve the current problem of confusion in Uncaria species, and makes a significant step forward in the appropriate clinical use, in-depth research and further utilization of different Uncaria species. Copyright © 2017 John Wiley & Sons, Ltd.
Lyman, Mathew; Rubinfeld, Bonnee; Leif, Roald; Mulcahy, Heather; Dugan, Lawrence; Souza, Brian
2018-01-01
Biosurfactants have several desirable characteristics in the industrial sector: detergency, antimicrobial effects, skin hydration, and emulsibility. Several yeast glycolipids are currently being utilized in these capacities: sophorolipids, ustilagic acid, and mannosylerythritol lipids (MELs). An emerging class of glycolipids, termed polyol esters of fatty acids (PEFA), have recently been reported for Rhodotorula babjevae, a basidiomycetous yeast species that secretes hyperacetylated congeners of PEFA (typically with 3-6 acetylation modifications). While screening Rhodotorula species for surfactant production, we identified a new environmental isolate identified as Rhodotorula taiwanensis MD1149 that dropped the surface tension of the liquid medium, indicating that it produced a potent biosurfactant. Acid depolymerization of the purified biosurfactants, followed by gas chromatography-mass spectrometry (GC-MS) analysis revealed that the biosurfactants were composed of PEFA compounds composed mainly of mannitol and arabitol esters of 3-hydroxy fatty acid, 3-methoxy fatty acid, and fatty acids with a single double bond; chain lengths were mainly C16 and C18. Liquid chromatography-mass spectrometry (LC-MS) confirmed the predicted accurate mass of these compounds. Interestingly, PEFA compounds produced by Rhodotorula taiwanensis MD1149 were more surface active due to their hypoacetylation profile (0-4 acetylation modifications) compared to Rhodotorula babjevae MD1169. These disparate surface active properties, based on acetylation, change the hydrophilic-lipophilic balance (HLB) of these compounds, and their potential utility within industrial applications.
Zhang, Tao; Ding, Yuanyuan; An, Hongli; Feng, Liuxin; Wang, Sicen
2015-07-14
Tyrosine 367 Cysteine-fibroblast growth factor receptor 4 cell membrane chromatography combined with high-performance liquid chromatography and mass spectrometry was developed. Tyrosine 367 Cysteine-HEK293 cells were used as cell membrane stationary phase. Specificity and reproducibility of the cell membrane chromatography was evaluated using 1-tert-butyl-3-{2-[4-(diethylamino)butylamino]-6-(3,5-dimethoxyphenyl)pyrido[2,3-d]pyrimidin-7-yl}urea, Nimodipine and dexamethasone acetate. Then, anti-tumor components acting on Tyrosine 367 Cysteine-fibroblast growth factor receptor 4 were screened and identified from extracts of Ligusticum wallichii. Components from the extract were retained on the cell membrane chromatographic column. The retained fraction was directly eluted into high-performance liquid chromatography with mass spectrometry system for separation and identification. Finally, Levistolide A was identified as an active component from Ligusticum wallichii extracts. The 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl-tetrazolium bromide-formazan colorimetric assay revealed that Levistolide A inhibits proliferation of overexpressing the mutated receptor cells with dose-dependent manner. Phosphorylation of fibroblast growth factor receptor 4 was also decrease under Levistolide A treatment. Flex dock simulation verified that Levistolide A could bind with the tyrosine kinase domain of fibroblast growth factor receptor 4. Therefore, Levistolide A screened by the cell membrane chromatography combined with high-performance liquid chromatography and mass spectrometry can arrest cell growth. In conclusion, the two-dimensional high-performance liquid chromatography method can screen and identify potential anti-tumor ingredients which specifically act on the tyrosine kinase domain of the mutated fibroblast growth factor receptor 4. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Total Synthesis of Ionic Liquid Systems for Dissolution of Lunar Simulant
NASA Technical Reports Server (NTRS)
Sharpe, Robert J.; Karr, Laurel J.; Paley, Mark S.
2010-01-01
For purposes of Space Resource Utilization, work in the total synthesis of a new ionic liquid system for the extraction of oxygen and metals from lunar soil is studied and described. Reactions were carried out according to procedures found in the chemical literature, analyzed via Thin-Layer Chromatography and 1H Nuclear Magnetic Resonance Spectroscopy and purified via vacuum distillation and rotary evaporation. Upon final analysis via 1H NMR, it was found that while the intermediates of the synthesis had been achieved, unexpected side products were also present. The mechanisms and constraints of the synthesis are described as well as the final results of the project and recommendations for continued study
Dixit, Shuchi; Dubey, Rituraj; Bhushan, Ravi
2014-01-01
Enantioresolution of four anti-ulcer drugs (chiral sulfoxides), namely, omeprazole, rabeprazole, lansoprazole and pantoprazole, was carried out by high-performance liquid chromatography using a polysaccharide-based chiral stationary phase consisting of monochloromethylated cellulose (Lux cellulose-2) under normal and polar-organic-phase conditions with ultraviolet detection at 285 nm. The method was validated for linearity, accuracy, precision, robustness and limit of detection. The optimized enantioresolution method was compared for both the elution modes. The optimized method was further utilized to check the enantiomeric purity of dexrabeprazole. Copyright © 2013 John Wiley & Sons, Ltd.
Ennis, Erin J; Foley, Joe P
2016-07-15
A stochastic approach was utilized to estimate the probability of a successful isocratic or gradient separation in conventional chromatography for numbers of sample components, peak capacities, and saturation factors ranging from 2 to 30, 20-300, and 0.017-1, respectively. The stochastic probabilities were obtained under conditions of (i) constant peak width ("gradient" conditions) and (ii) peak width increasing linearly with time ("isocratic/constant N" conditions). The isocratic and gradient probabilities obtained stochastically were compared with the probabilities predicted by Martin et al. [Anal. Chem., 58 (1986) 2200-2207] and Davis and Stoll [J. Chromatogr. A, (2014) 128-142]; for a given number of components and peak capacity the same trend is always observed: probability obtained with the isocratic stochastic approach
Sheng, Qianying; Yang, Kaiya; Ke, Yanxiong; Liang, Xinmiao; Lan, Minbo
2016-09-01
Maltose covalently bonded to silica was prepared by using carbonyl diimidazole as a cross-linker and employed as a stationary phase for hydrophilic interaction liquid chromatography. The column efficiency and the effect of water content, buffer concentration, and pH value influenced on retention were investigated. The separation or enrichment selectivity was also studied with nucleosides, saccharides, amino acids, peptides, and glycopeptides. The results indicated that the stationary phase processed good separation efficiency and separation selectivity in hydrophilic interaction liquid chromatography mode. Moreover, a two-dimensional hydrophilic interaction liquid chromatography× reversed-phase liquid chromatography method with high orthogonality was developed to analyze the Ginkgo Biloba extract fractions. The development of this two-dimensional chromatographic system would be an effective tool for the separation of complex samples of different polarities and contents. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
High Performance Liquid Chromatography of Vitamin A: A Quantitative Determination.
ERIC Educational Resources Information Center
Bohman, Ove; And Others
1982-01-01
Experimental procedures are provided for the quantitative determination of Vitamin A (retinol) in food products by analytical liquid chromatography. Standard addition and calibration curve extraction methods are outlined. (SK)
Reichel, W.L.; Prouty, R.M.; Gay, M.L.
1977-01-01
Unknown compounds detected in Ardea herodias tissues are identified by gas-liquid chromatography-mass spectrometry as residues of octachlorostyrene. Heptachlorostyrene and hexachlorostyrene were tentatively identified.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Chromatography/Mass Spectrometry (GC/MS) 525.3 24 Carbofuran High-performance liquid chromatography (HPLC) with... (HPLC) with Post-Column Derivatization and Fluorescence Detection 6651 B 6651 B 6651 B-00. Heptachlor... Spectrometry (GC/MS) 525.3 24 Oxamyl High-performance liquid chromatography (HPLC) with post-column...
Li, Senlin; Li, Sainan; Huang, Yu; Liu, Chunming; Chen, Lina; Zhang, Yuchi
2017-06-01
The separation of a compound of interest from its structurally similar homologues to produce high-purity natural products is a challenging problem. This work proposes a novel method for the separation of iristectorigenin A from its structurally similar homologues by ionic-liquid-based ultrasound-assisted extraction and the subsequent screening and isolation of potential α-glucosidase inhibitors via ultrafiltration and semipreparative high-performance liquid chromatography. Ionic-liquid-based ultrasound-assisted extraction was successfully applied to the extraction of tectorigenin, iristectorigenin A, irigenin, and irisflorentin from Belamcanda chinensis. The optimum conditions for the efficient extraction of isoflavones were determined as 1.0 M 1-ethyl-3-methylimidazolium tetrafluoroborate with extraction time of 30 min and a solvent to solid ratio of 30 mL/g. Ultrafiltration with liquid chromatography and mass spectrometry was applied to screen and identify α-glucosidase inhibitors from B. chinensis, followed by the application of semipreparative high-performance liquid chromatography to separate and isolate the active constituents. Four major compounds including tectorigenin, iristectorigenin A, irigenin, and irisflorentin were screened and identified as α-glucosidase inhibitors, and then the four active compounds abovementioned were subsequently isolated by semipreparative high-performance liquid chromatography (99.89, 88.97, 99.79, and 99.97% purity, respectively). The results demonstrate that ionic liquid extraction can be successfully applied to the extraction of isoflavones from B. chinensis. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Free silanols and ionic liquids as their suppressors in liquid chromatography.
Buszewska-Forajta, Magdalena; Markuszewski, Michał J; Kaliszan, Roman
2018-07-20
In this review, we will firstly discuss the types and the general properties of silica, focusing on the silica support used in chromatography and capillary electrophoresis. Additionally, the characterization of functional groups (silanols and siloxanes) will be considered in terms of activity of the stationary phases. We will then discuss physical chemistry of the stationary phases applied in liquid chromatography and capillary electrophoresis. The use of ionic liquids as a silanols' suppressors will be presented in the next parts of the study, along with the examples of specific applications. The review is completed with conclusions and an outlook for the future developments in the area of analytical applications of ionic liquids. Copyright © 2018 Elsevier B.V. All rights reserved.
A generalized theory of chromatography and multistep liquid extraction
NASA Astrophysics Data System (ADS)
Chizhkov, V. P.; Boitsov, V. N.
2017-03-01
A generalized theory of chromatography and multistep liquid extraction is developed. The principles of highly efficient processes for fine preparative separation of binary mixture components on a fixed sorbent layer are discussed.
Preparation of pure microbiological samples for pyrolysis gas-liquid chromatography studies
NASA Technical Reports Server (NTRS)
Oxborrow, G. S.; Fields, N. D.; Puleo, J. R.
1976-01-01
Bacterial samples were prepared for pyrolysis gas-liquid chromatography using cells grown on membrane filters. Pyrochromatograms were reproducible when cells harvested from the filters were pyrolyzed without being washed.
Mathias, Patricia I; B'Hymer, Clayton
2014-08-01
High-performance liquid chromatography/mass spectrometry (HPLC/MS) is sensitive and specific for targeted quantitative analysis and is readily utilized for small molecules from biological matrices. This brief review describes recent selected HPLC/MS methods for the determination of urinary mercapturic acids (mercapturates) which are useful as biomarkers in characterizing human exposure to electrophilic industrial chemicals in occupational and environmental studies. Electrophilic compounds owing to their reactivity are used in chemical and industrial processes. They are present in industrial emissions, are combustion products of fossil fuels, and are components in tobacco smoke. Their presence in both the industrial and general environments are of concern for human and environmental health. Urinary mercapturates which are the products of metabolic detoxification of reactive chemicals provide a non-invasive tool to investigate human exposure to electrophilic toxicants. Selected recent mercapturate quantification methods are summarized and specific cases are presented. The biological formation of mercapturates is introduced and their use as biomarkers of metabolic processing of electrophilic compounds is discussed. Also, the use of liquid chromatography/tandem mass spectrometry in simultaneous determinations of the mercapturates of multiple parent compounds in a single determination is considered, as well as future trends and limitations in this area of research. Published by Elsevier B.V.
Bailey, C; Kitchen, I
1985-06-01
A method is described for the separation of proenkephalin products using gradient high-performance liquid chromatography preceded by Sep-Pak chromatography. Samples can be assayed simply by use of a modified mouse vas deferens bioassay which is sufficiently sensitive for most applications. The preliminary Sep-Pak chromatography method excludes alpha-neoendorphin and the dynorphins and thus provides a suitable procedure for separation of prodynorphin and proenkephalin products.
Stable Isotope Quantitative N-Glycan Analysis by Liquid Separation Techniques and Mass Spectrometry.
Mittermayr, Stefan; Albrecht, Simone; Váradi, Csaba; Millán-Martín, Silvia; Bones, Jonathan
2017-01-01
Liquid phase separation analysis and subsequent quantitation remains a challenging task for protein-derived oligosaccharides due to their inherent structural complexity and diversity. Incomplete resolution or co-detection of multiple glycan species complicates peak area-based quantitation and associated statistical analysis when optical detection methods are used. The approach outlined herein describes the utilization of stable isotope variants of commonly used fluorescent tags that allow for mass-based glycan identification and relative quantitation following separation by liquid chromatography (LC) or capillary electrophoresis (CE). Comparability assessment of glycoprotein-derived oligosaccharides is performed by derivatization with commercially available isotope variants of 2-aminobenzoic acid or aniline and analysis by LC- and CE-mass spectrometry. Quantitative information is attained from the extracted ion chromatogram/electropherogram ratios generated from the light and heavy isotope clusters.
Isolation of Gregatin A from Phialophora gregata by Preparative High-Pressure Liquid Chromatography
Taylor, Scott L.; Peterson, Robert E.; Gray, Lynn E.
1985-01-01
A method was developed for the production and purification of gregatin A from Phialophora gregata NRRL 13198 cultured on rice at 20°C for 28 days. Liquid extraction followed by high-pressure liquid chromatography afforded 247.0 mg of crystalline gregatin A per kg of rice. PMID:16346936
Damm, Irina; Enger, Eileen; Chrubasik-Hausmann, Sigrun; Schieber, Andreas; Zimmermann, Benno F
2016-08-01
Fast methods for the extraction and analysis of various secondary metabolites from cocoa products were developed and optimized regarding speed and separation efficiency. Extraction by pressurized liquid extraction is automated and the extracts are analyzed by rapid reversed-phase ultra high-performance liquid chromatography and normal-phase high-performance liquid chromatography methods. After extraction, no further sample treatment is required before chromatographic analysis. The analytes comprise monomeric and oligomeric flavanols, flavonols, methylxanthins, N-phenylpropenoyl amino acids, and phenolic acids. Polyphenols and N-phenylpropenoyl amino acids are separated in a single run of 33 min, procyanidins are analyzed by normal-phase high-performance liquid chromatography within 16 min, and methylxanthins require only 6 min total run time. A fourth method is suitable for phenolic acids, but only protocatechuic acid was found in relevant quantities. The optimized methods were validated and applied to 27 dark chocolates, one milk chocolate, two cocoa powders and two food supplements based on cocoa extract. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Pirok, Bob W J; Knip, Jitske; van Bommel, Maarten R; Schoenmakers, Peter J
2016-03-04
In the late 19th century, newly invented synthetic dyes rapidly replaced the natural dyes on the market. The characterization of mixtures of these so-called early synthetic dyes is complicated through the occurrence of many impurities and degradation products. Conventional one-dimensional liquid chromatography does not suffice to obtain fingerprints with sufficient resolution and baseline integrity. Comprehensive two-dimensional liquid chromatography (LC×LC) is employed in this study, with ion-exchange chromatography in the first dimension and fast ion-pair liquid chromatography in the second. Retention in the first dimension is largely determined by the number of charges, while the selection of a small ion-pair reagent (tetramethylammonium hydroxide) in the second dimension causes retention to be largely determined by the molecular structure of the dye. As a result, there is a high degree of orthogonality of the two dimensions, similar to the values typically encountered in GC×GC. The proposed LC×LC method shows a theroretical peak capacity of about 2000 in an analysis time of about three hours. Clear, informative fingerprints are obtained that open a way to a more efficient characterization of dyes used in objects of cultural heritage. Copyright © 2016 Elsevier B.V. All rights reserved.
Yang, Lijun; Hu, Qiaoru; Guo, Wei; Liu, Yumin; Song, Xiaohua; Zhang, Pengcheng
2011-05-01
A method for the simultaneous determination of 7 arsenic species was developed with high performance liquid chromatography and inductively coupled plasma mass spectrometry (HPLC-ICP-MS). The sample was extracted with artificial gastric juice. The HPLC separation was performed on an anion analytical column utilizing a gradient elution program of ammonium carbonate and water as the mobile phase. Identification and quantification were achieved by ICP-MS. Good linearities of 7 arsenic species were observed in the range from 1 microg/kg to 50 microg/kg with the correlation coefficients greater than 0.999. The average recoveries of 7 arsenic species spiked at the three levels of 1, 2 and 10 microg/kg ranged from 84.3% to 106.6% with the relative standard deviations of 1.4%-4.2%. The quantification limits of 7 arsenic species were 1 microg/kg. The method was proved to be good reproducibility, high sensitivity and simple preprocessing. This method is suitable for the simultaneous determination of 7 arsenic species in chicken muscle and chicken liver.
McIlhenny, Ethan H; Pipkin, Kelly E; Standish, Leanna J; Wechkin, Hope A; Strassman, Rick; Barker, Steven A
2009-12-18
A direct injection/liquid chromatography-electrospray ionization-tandem mass spectrometry procedure has been developed for the simultaneous quantitation of 11 compounds potentially found in the increasingly popular Amazonian botanical medicine and religious sacrament ayahuasca. The method utilizes a deuterated internal standard for quantitation and affords rapid detection of the alkaloids by a simple dilution assay, requiring no extraction procedures. Further, the method demonstrates a high degree of specificity for the compounds in question, as well as low limits of detection and quantitation despite using samples for analysis that had been diluted up to 200:1. This approach also appears to eliminate potential matrix effects. Method bias for each compound, examined over a range of concentrations, was also determined as was inter- and intra-assay variation. Its application to the analysis of three different ayahuasca preparations is also described. This method should prove useful in the study of ayahuasca in clinical and ethnobotanical research as well as in forensic examinations of ayahuasca preparations.
Yeung, B; Vouros, P; Reddy, G S
1993-08-13
A mass spectrometric method for the detection of vitamin D3 metabolites is described. This method involves the derivatization of the metabolites by cycloaddition with 4-phenyl-1,2,4-triazoline-3,5-dione, followed by their characterization by continuous-flow fast atom bombardment (CF-FAB) tandem mass spectrometry (MS-MS) and high-performance liquid chromatography (HPLC). Using HPLC, this derivatization has been shown to increase the UV detectability of 25-hydroxyvitamin D3 by about 5-fold. The FAB spectra of the adducts are dominated by peaks corresponding to a protonated molecule and a fragment ion derived in part from the loss of the side chain. Multiple reaction monitoring (MRM) of this transition by MS-MS may be utilized for trace level analysis of vitamin D metabolites. Sample introduction by flow injection yields detection limits in the low nanogram to high picogram range, whereas the use of on-line capillary LC has been found to decrease the detection limits to the low picogram level.
Wang, Guoying; Jia, Shiming; Niu, Xiuli; Liu, Yanrong; Tian, Haoqi; Chen, Xuefu; Shi, Gaofeng
2018-01-22
Free radicals play an important role in the oxidizing power of polluted air, the development of aging-related diseases, the formation of ozone, and the production of secondary particulate matter. The high variability of peroxyl radical concentration has prevented the detection of possible trends or distributions in the concentration of free radicals. We present a new method, free radical reaction combined with liquid chromatography photodiode array detection, for identifying and quantifying peroxyl radicals in polluted air. Functionalized graphene was used for loading peroxyl radicals and reactive molecules in air sampling system, which can facilitate reaction kinetics (charge transfers) between peroxyl radicals and reaction molecules. Separation was performed with and without a preliminary exposure of the polluted air sample to reactive molecule(s) system. The integral chromatographic peak areas before and after air sampling are used to quantify the atmospheric peroxyl radicals in polluted air. The utility of the new technique was tested with measurements carried out in the field. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Haldar, Saikat; Mulani, Fayaj A; Aarthy, Thiagarayaselvam; Dandekar, Devdutta S; Thulasiram, Hirekodathakallu V
2014-10-31
C-seco triterpenoids are widely bioactive class of natural products with high structural complexity and diversity. The preparative isolation of these molecules with high purity is greatly desirable, although restricted due to the complexity of natural extracts. In this article we have demonstrated a Medium Pressure Liquid Chromatography (MPLC) based protocol for the isolation of eight major C-seco triterpenoids of salannin skeleton from Neem (Azadirachta indica) oil. Successive application of normal phase pre-packed silica-gel columns for the fractionation followed by reverse phase in automated MPLC system expedited the process and furnished highly pure metabolites. Furthermore, eight isolated triterpenoids along with five semi-synthesized derivatives were characterized using ultra performance liquid chromatography-electrospray ionization-quadrupole/orbitrap-MS/MS spectrometry as a rapid and sensitive identification technique. The structure-fragment relationships were established on the basis of plausible mechanistic pathway for the generation of daughter ions. The MS/MS spectral information of the triterpenoids was further utilized for the identification of studied molecules in the complex extract of stem and bark tissues from Neem. Copyright © 2014 Elsevier B.V. All rights reserved.
Xia, Xi; Li, Xiaowei; Ding, Shuangyang; Zhang, Suxia; Jiang, Haiyang; Li, Jiancheng; Shen, Jianzhong
2009-03-20
This work reports a rapid, reliable and sensitive multi-residue method for the simultaneous determination of six resorcylic acid lactones in bovine milk by ultra-high-pressure liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). The resorcylic acid lactones were extracted, purified, and concentrated from milk samples in one step using a solid-phase extraction (SPE) cartridge that contained a polymeric mixed-mode anion-exchange sorbent. The analysis was performed on a Waters Acquity BEH C(18) column utilizing a gradient elution profile. Each LC run was completed in 3.5 min. The analytes were detected by multiple reaction monitoring (MRM) using electrospray ionization (ESI) negative mode. Mean recoveries from fortified samples ranged from 92.6% to 112.5%, with relative standard deviations lower than 11.4%. Using 5 mL bovine milk, the limits of detection and quantification for resorcylic acid lactones were in the ranges of 0.01-0.05 and 0.05-0.2 microg/L, respectively. The application of this newly developed method was demonstrated by analyzing bovine milk samples from markets.
Zhou, Qingxiang; Fang, Zhi; Liao, Xiangkun
2015-07-01
We describe a highly sensitive micro-solid-phase extraction method for the pre-concentration of six phthalate esters utilizing a TiO2 nanotube array coupled to high-performance liquid chromatography with a variable-wavelength ultraviolet visible detector. The selected phthalate esters included dimethyl phthalate, diethyl phthalate, dibutyl phthalate, butyl benzyl phthalate, bis(2-ethylhexyl)phthalate and dioctyl phthalate. The factors that would affect the enrichment, such as desorption solvent, sample pH, salting-out effect, extraction time and desorption time, were optimized. Under the optimum conditions, the linear range of the proposed method was 0.3-200 μg/L. The limits of detection were 0.04-0.2 μg/L (S/N = 3). The proposed method was successfully applied to the determination of six phthalate esters in water samples and satisfied spiked recoveries were achieved. These results indicated that the proposed method was appropriate for the determination of trace phthalate esters in environmental water samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
DOE Office of Scientific and Technical Information (OSTI.GOV)
LaFreniere, K.E.
A direct injection nebulizer (DIN) was designed, developed, and evaluated to determine its potential utilization as an effective interface for flow injection analysis (FIA) and high performance liquid chromatography (HPLC) coupled with inductively coupled plasma-atomic emission spectroscopic detection. The analytical figures of merit for the DIN when used as an interface for FIA-ICP-AES were found to be comparable to or better than those obtained with conventional pneumatic nebulization in terms of limits of detection (LODs), reproducibility, linearity, and interelement effects. Stable plasma operation was maintained for the DIN sample introduction of a variety of pure organic solvents, including acetonitrile, methanol,more » methylisobutylketone, and pyridine. The HPLC-DIN-ICP-AES facility was specifically applied for the speciation of inorganic and organometallic species contained in synthetic mixtures, vanilla extracts, and a variety of energy-related materials, such as shale oil process water, coal extracts, shale oil, crude oil, and an SRC II. Suggestions for future research are also considered. 227 refs., 44 figs., 15 tabs.« less
Avagyan, Rozanna; Sadiktsis, Ioannis; Thorsén, Gunnar; Östman, Conny; Westerholm, Roger
2013-09-13
A high performance liquid chromatography-tandem mass spectrometry method utilizing electrospray ionization in positive and negative mode has been developed for the separation and detection of benzothiazole and benzotriazole derivates. Ultra-sonication assisted solvent extraction of these compounds has also been developed and the overall method demonstrated on a selected clothing textile and an automobile tire sample. Matrix effects and extraction recoveries, as well as linearity and limits of detection have been evaluated. The calibration curves spanned over more than two orders of magnitude with coefficients of correlation R(2)>0.99 and the limits of detection and the limits of quantification were in the range 1.7-58pg injected and 18-140pg/g, respectively. The extraction recoveries ranged between 69% and 102% and the matrix effects between 75% and 101%. Benzothiazole and benzotriazole derivates were determined in the textile sample and benzothiazole derivatives determined in the tire sample with good analytical performance. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Susanto, D. F.; Hapsari, S.; Trilutfiani, Z.; Borhet, A.; Aparamarta, H. W.; Widjaja, A.; Gunawan, S.
2018-03-01
Calophyllum inophyllum has various benefits that can be utilized from root, stem, leaf, until seed. C. inophyllum leaves contain many bioactive compounds, such as xanthone and coumarin which are useful as antioxidant, and inhibitors of enzyme activity from HIV virus. The aim of this research was to investigate the effect of solvent polarity levels on the separation of xanthone and coumarin compounds contained in the crude extract of C. inophyllum leaves. Crude leaves extract was obtained by percolation method. Moreover, Liquid Liquid Extraction (LLE) was used for separating xanthone and coumarin compounds. It was performed by methanol (polar solvent) and hexane (non-polar solvent) with solvent ratio of 1. Methanol concentration in water used were 20%, 50%, 80%, and 100%. Each fraction obtained was tested qualitatively using Thin Layer Chromatography (TLC) and quantitatively using Gas Chromatography (GC) to analyze xanthone and coumarin. The best separation result was obtained by using 50% methanol. In this results, coumarin and xanthones were separated in methanol fraction (81.18% recovery) and in hexane fraction (81.91% recovery), respectively.
Hill, Ryan C; Oman, Trent J; Shan, Guomin; Schafer, Barry; Eble, Julie; Chen, Cynthia
2015-08-26
Currently, traditional immunochemistry technologies such as enzyme-linked immunosorbent assays (ELISA) are the predominant analytical tool used to measure levels of recombinant proteins expressed in genetically engineered (GE) plants. Recent advances in agricultural biotechnology have created a need to develop methods capable of selectively detecting and quantifying multiple proteins in complex matrices because of increasing numbers of transgenic proteins being coexpressed or "stacked" to achieve tolerance to multiple herbicides or to provide multiple modes of action for insect control. A multiplexing analytical method utilizing liquid chromatography with tandem mass spectrometry (LC-MS/MS) has been developed and validated to quantify three herbicide-tolerant proteins in soybean tissues: aryloxyalkanoate dioxygenase (AAD-12), 5-enol-pyruvylshikimate-3-phosphate synthase (2mEPSPS), and phosphinothricin acetyltransferase (PAT). Results from the validation showed high recovery and precision over multiple analysts and laboratories. Results from this method were comparable to those obtained with ELISA with respect to protein quantitation, and the described method was demonstrated to be suitable for multiplex quantitation of transgenic proteins in GE crops.
NASA Astrophysics Data System (ADS)
Hvastkovs, Eli, G.; Schenkman, John B.; Rusling, James, F.
2012-07-01
New chemicals or drugs must be guaranteed safe before they can be marketed. Despite widespread use of bioassay panels for toxicity prediction, products that are toxic to a subset of the population often are not identified until clinical trials. This article reviews new array methodologies based on enzyme/DNA films that form and identify DNA-reactive metabolites that are indicators of potentially genotoxic species. This molecularly based methodology is designed in a rapid screening array that utilizes electrochemiluminescence (ECL) to detect metabolite-DNA reactions, as well as biocolloid reactors that provide the DNA adducts and metabolites for liquid chromatography-mass spectrometry (LC-MS) analysis. ECL arrays provide rapid toxicity screening, and the biocolloid reactor LC-MS approach provides a valuable follow-up on structure, identification, and formation rates of DNA adducts for toxicity hits from the ECL array screening. Specific examples using this strategy are discussed. Integration of high-throughput versions of these toxicity-screening methods with existing drug toxicity bioassays should allow for better human toxicity prediction as well as more informed decision making regarding new chemical and drug candidates.
Xie, Yuan-yuan; Xiao, Xue; Luo, Juan-min; Fu, Chan; Wang, Qiao-wei; Wang, Yi-ming; Liang, Qiong-lin; Luo, Guo-an
2014-06-01
The present study aims to describe and exemplify an integrated strategy of the combination of qualitative and quantitative characterization of a multicomponent mixture for the quality control of traditional Chinese medicine injections with the example of Danhong injection (DHI). The standardized chemical profile of DHI has been established based on liquid chromatography with diode array detection. High-performance liquid chromatography coupled with time-of-flight mass spectrometry and high-performance liquid chromatography with electrospray multistage tandem ion-trap mass spectrometry have been developed to identify the major constituents in DHI. The structures of 26 compounds including nucleotides, phenolic acids, and flavonoid glycosides were identified or tentatively characterized. Meanwhile, the simultaneous determination of seven marker constituents, including uridine, adenosine, danshensu, protocatechuic aldehyde, p-coumaric acid, rosmarinic acid, and salvianolic acid B, in DHI was performed by multiwavelength detection based on high-performance liquid chromatography with diode array detection. The integrated qualitative and quantitative characterization strategy provided an effective and reliable pattern for the comprehensive and systematic characterization of the complex traditional Chinese medicine system. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
ERIC Educational Resources Information Center
Beaver, Rodney W.; And Others
1983-01-01
Describes an experiment on the qualitative analysis of several over-the-counter analgesic tablets. Background information, procedures used (including high pressure liquid chromatography), and typical student results are included. (JN)
Haggarty, Jennifer; Burgess, Karl Ev
2017-02-01
The metabolome is the complete complement of metabolites (small organic biomolecules). In order to comprehensively understand the effect of stimuli on a biological system, it is important to detect as many of the metabolites within that system as possible. This review briefly describes some new advances in liquid and gas chromatography to improve coverage of the metabolome, including the serial combination of two columns in tandem, column switching and different variations of two-dimensional chromatography. Supercritical fluid chromatography could provide complimentary data to liquid and gas chromatography. Although there have been many recent advancements in the field of metabolomics, it is evident that a combination, rather than a single method, is required to approach full coverage of the metabolome. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
The gas–liquid chromatography of carboxylic acid esters of the urinary 11-deoxy-17-oxo steroids
Sadler, Patricia A.; Kellie, A. E.
1967-01-01
1. The gas–liquid-chromatographic separations of the acetate, propionate, n-butyrate, isobutyrate and n-valerate esters of androsterone, aetiocholanolone and dehydroepiandrosterone were studied on a 1% neopentyl glycol sebacate column. The n-butyrate, isobutyrate and n-valerate esters were well resolved. 2. The three steroids derived from hydrolysed urinary 17-oxo steroid conjugate extracts were analysed by gas–liquid chromatography after conversion into their n-butyrate esters. The results were compared with independent determinations involving chromatography on alumina. PMID:4227802
Sadler, P A; Kellie, A E
1967-06-01
1. The gas-liquid-chromatographic separations of the acetate, propionate, n-butyrate, isobutyrate and n-valerate esters of androsterone, aetiocholanolone and dehydroepiandrosterone were studied on a 1% neopentyl glycol sebacate column. The n-butyrate, isobutyrate and n-valerate esters were well resolved. 2. The three steroids derived from hydrolysed urinary 17-oxo steroid conjugate extracts were analysed by gas-liquid chromatography after conversion into their n-butyrate esters. The results were compared with independent determinations involving chromatography on alumina.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Spectrometry (GC/MS) 525.3 24 Carbofuran High-performance liquid chromatography (HPLC) with post-column... (HPLC) with Post-Column Derivatization and Fluorescence Detection 6651 B 6651 B 6651 B-00, B-05... Chromatography/Mass Spectrometry (GC/MS) 525.3 24 Oxamyl High-performance liquid chromatography (HPLC) with post...
Ionic Liquid-Liquid Chromatography: A New General Purpose Separation Methodology.
Brown, Leslie; Earle, Martyn J; Gîlea, Manuela A; Plechkova, Natalia V; Seddon, Kenneth R
2017-08-10
Ionic liquids can form biphasic solvent systems with many organic solvents and water, and these solvent systems can be used in liquid-liquid separations and countercurrent chromatography. The wide range of ionic liquids that can by synthesised, with specifically tailored properties, represents a new philosophy for the separation of organic, inorganic and bio-based materials. A customised countercurrent chromatograph has been designed and constructed specifically to allow the more viscous character of ionic liquid-based solvent systems to be used in a wide variety of separations (including transition metal salts, arenes, alkenes, alkanes, bio-oils and sugars).
Preparation of pure microbiological samples for pyrolysis of gas-liquid chromatography studies.
Oxborrow, G S; Fields, N D; Puleo, J R
1976-01-01
Bacterial samples were prepared for pyrolysis gas-liquid chromatography using cells grown on membrane filters. Pyrochromatograms were reproducible when cells harvested from the filters were pyrolyzed without being washed. Images PMID:970947
75 FR 38156 - Small Business Size Standards: Waiver of the Nonmanufacturer Rule
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-01
... Systems (CS-MS), High Performance Liquid Chromatography (HPLC) Systems, Gas Chromatography Mass... Chromatography (HPLC) Systems, Gas Chromatography Mass Spectrometry (GC-MS) Systems, and, Inductively Coupled...
Li, Jia-Fu; Fang, Hua; Yan, Xia; Chang, Fang-Rong; Wu, Zhen; Wu, Yun-Long; Qiu, Ying-Kun
2016-07-22
An on-line comprehensive preparative two-dimensional normal-phase liquid chromatography×reversed-phase liquid chromatography (2D NPLC×RPLC) system was constructed with a newly developed vacuum evaporation assisted adsorption (VEAA) interface, allowing fast removal of NPLC solvent in the vacuum condition and successfully solving the solvent incompatibility problem between NPLC and RPLC. The system achieved on-line solvent exchange within the two dimensions and its performance was illustrated by gram-scale isolation of crude extract from the venom of Bufo bufo gargarizans. Within separation time of ∼20h, 19 compounds were obtained with high purity in a single run. With the VEAA interface, the 2D system exhibited apparent advantages in separation efficiency and automation compared with conventional methods, indicating its promising application in the routine separation process for complicated natural products. Copyright © 2016 Elsevier B.V. All rights reserved.
Micro-polarimeter for high performance liquid chromatography
Yeung, Edward E.; Steenhoek, Larry E.; Woodruff, Steven D.; Kuo, Jeng-Chung
1985-01-01
A micro-polarimeter interfaced with a system for high performance liquid chromatography, for quantitatively analyzing micro and trace amounts of optically active organic molecules, particularly carbohydrates. A flow cell with a narrow bore is connected to a high performance liquid chromatography system. Thin, low birefringence cell windows cover opposite ends of the bore. A focused and polarized laser beam is directed along the longitudinal axis of the bore as an eluent containing the organic molecules is pumped through the cell. The beam is modulated by air gap Faraday rotators for phase sensitive detection to enhance the signal to noise ratio. An analyzer records the beams's direction of polarization after it passes through the cell. Calibration of the liquid chromatography system allows determination of the quantity of organic molecules present from a determination of the degree to which the polarized beam is rotated when it passes through the eluent.
Araujo, Pedro; Tilahun, Ephrem; Breivik, Joar Fjørtoft; Abdulkader, Bashir M; Frøyland, Livar; Zeng, Yingxu
2016-02-01
It is well-known that triacylglycerol (TAG) ions are suppressed by phospholipid (PL) ions in regiospecific analysis of TAG by mass spectrometry (MS). Hence, it is essential to remove the PL during sample preparation prior to MS analysis. The present article proposes a cost-effective liquid-liquid extraction (LLE) method to remove PL from TAG in different kinds of biological samples by using methanol, hexane and water. High performance thin layer chromatography confirmed the lack of PL in krill oil and salmon liver samples, submitted to the proposed LLE protocol, and liquid chromatography tandem MS confirmed that the identified TAG ions were highly enhanced after implementing the LLE procedure. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Schindler, Matthias; Kretschmer, Wolfgang; Scharf, Andreas; Tschekalinskij, Alexander
2016-05-01
Three new methods to sample and prepare various carbonyl compounds for radiocarbon measurements were developed and tested. Two of these procedures utilized the Strecker synthetic method to form amino acids from carbonyl compounds with either sodium cyanide or trimethylsilyl cyanide. The third procedure used semicarbazide to form crystalline carbazones with the carbonyl compounds. The resulting amino acids and semicarbazones were then separated and purified using thin layer chromatography. The separated compounds were then combusted to CO2 and reduced to graphite to determine 14C content by accelerator mass spectrometry (AMS). All of these methods were also compared with the standard carbonyl compound sampling method wherein a compound is derivatized with 2,4-dinitrophenylhydrazine and then separated by high-performance liquid chromatography (HPLC).
Yang, Bichao; Xin, Huaxia; Wang, Feier; Cai, Jianfeng; Liu, Yanfang; Fu, Qing; Jin, Yu; Liang, Xinmiao
2017-08-01
As a common traditional Chinese medicine, Fructus Arctii has important clinical medical values. Its main components are lignans, which are difficult to separate and analyze because of the complex composition, similar chemical structures, and close properties. In this study, an off-line two-dimensional supercritical fluid chromatography/reversed-phase liquid chromatography method, as well as an effective sample pretreatment method based on hydrophilic interaction chromatography material, was developed to enrich the minor lignan fractions and obtain high-purity compounds. In total, 12 high-purity compounds were isolated from Fructus Arctii. Their structures were identified by using high-resolution mass spectrometry and nuclear magnetic resonance spectroscopy, which showed that all were lignans and that most of them were isomers. The results demonstrated the effective off-line two-dimensional supercritical fluid chromatography/reversed-phase liquid chromatography method for the purification of lignans from Fructus Arctii. The separation protocol established here will be beneficial for the separation of complex samples from other kinds of natural products. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Two-Dimensional Liquid Chromatography Analysis of Polystyrene/Polybutadiene Block Copolymers.
Lee, Sanghoon; Choi, Heejae; Chang, Taihyun; Staal, Bastiaan
2018-05-15
A detailed characterization of a commercial polystyrene/polybutadiene block copolymer material (Styrolux) was carried out using two-dimensional liquid chromatography (2D-LC). The Styrolux is prepared by statistical linking reaction of two different polystyrene- block-polybutadienyl anion precursors with a multivalent linking agent. Therefore, it is a mixture of a number of branched block copolymers different in molecular weight, composition, and chain architecture. While individual LC analysis, including size exclusion chromatography, interaction chromatography, or liquid chromatography at critical condition, is not good enough to resolve all the polymer species, 2D-LC separations coupling two chromatography methods were able to resolve all polymer species present in the sample; at least 13 block copolymer species and a homopolystyrene blended. Four different 2D-LC analyses combining a different pair of two LC methods provide their characteristic separation results. The separation characteristics of the 2D-LC separations are compared to elucidate the elution characteristics of the block copolymer species.
Fractionation of sheep cheese whey by a scalable method to sequentially isolate bioactive proteins.
Pilbrow, Jodi; Bekhit, Alaa El-Din A; Carne, Alan
2016-07-15
This study reports a procedure for the simultaneous purification of glyco(caseino)macropeptide, immunoglobulin, lactoperoxidase, lactoferrin, α-lactalbumin and β-lactoglobulin from sheep cheese sweet whey, an under-utilized by-product of cheese manufacture generated by an emerging sheep dairy industry in New Zealand. These proteins have recognized value in the nutrition, biomedical and health-promoting supplements industries. A sequential fractionation procedure using economical anion and cation exchange chromatography on HiTrap resins was evaluated. The whey protein fractionation is performed under mild conditions, requires only the adjustment of pH between ion exchange chromatography steps, does not require buffer exchange and uses minimal amounts of chemicals. The purity of the whey protein fractions generated were analyzed by reversed phase-high performance liquid chromatography and the identity of the proteins was confirmed by mass spectrometry. This scalable procedure demonstrates that several proteins of recognized value can be fractionated in reasonable yield and purity from sheep cheese whey in one streamlined process. Copyright © 2016 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zheng, Xueyun; Wojcik, Roza; Zhang, Xing
Ion mobility spectrometry (IMS) is a widely used analytical technique for rapid molecular separations in the gas phase. IMS alone is useful, but its coupling with mass spectrometry (MS) and front-end separations has been extremely beneficial for increasing measurement sensitivity, peak capacity of complex mixtures, and the scope of molecular information in biological and environmental sample analyses. Multiple studies in disease screening and environmental evaluations have even shown these IMS-based multidimensional separations extract information not possible with each technique individually. This review highlights 3-dimensional separations using IMS-MS in conjunction with a range of front-end techniques, such as gas chromatography (GC),more » supercritical fluid chromatography (SFC), liquid chromatography (LC), solid phase extractions (SPE), capillary electrophoresis (CE), field asymmetric ion mobility spectrometry (FAIMS), and microfluidic devices. The origination, current state, various applications, and future capabilities for these multidimensional approaches are described to provide insight into the utility and potential of each technique.« less
Abe, P M; Kendall, C J; Stauffer, L R; Holland, J W
1979-01-01
Culture supernatants of Fusobacterium necrophorum demonstrated hemolytic activity. The hemolysin(s), which was partially purified by ammonium sulfate precipitation, was temperature-dependent and heat labile. The spectrum of hemolytic activity against various erythrocytes included rabbit, human, and dog erythrocytes. Goats, sheep, and bovine erythrocytes showed only trace hemolysis. According to results of thin-layer chromatography, the hemolysin hydrolyzed rabbit erythrocyte phosphatidyl choline, phosphatidyl ethanolamine, lysophosphatidyl choline, and bovine phosphatidyl choline. Hydrolysis of egg yolk phosphatidyl choline, bovine phosphatidyl ethanolamine, cholesterol, 1,2-dipalmitin, 1,3-dipalmitin, sphingomyelin, or triolein was not detected by thin layer chromatography. A more sensitive procedure utilizing gas-liquid chromatography revealed that, of the substrates tested, the following were bein hydrolyzed: bovine and egg yolk phosphatidyl choline, lysophosphatidyl choline, alpha-palmito-beta-eleoyl-L-alpha lecithin and alpha-oleoyl-betal-palmitoyl-L-alpha lecithin. Substrates which were weakly hydrolyzed were bovine phosphatidyl ethanolamine, DL-alpha-hosphatidyl ethanolamine dipalmitoyl, 1,2-dipalmitin, 1,3-dipalmitin, and triolein.
Lipidomic analysis of glycerolipid and cholesteryl ester autooxidation products.
Kuksis, Arnis; Suomela, Jukka-Pekka; Tarvainen, Marko; Kallio, Heikki
2009-06-01
Thin-layer chromatography (TLC), gas chromatography (GC), and liquid chromatography (LC) in combination with mass spectrometry (MS) have been adopted for the isolation and identification of oxolipids and for determining their functionality. TLC provides a rapid separation and access to most oxolipids as intact molecules and has recently been effectively interfaced with time-of-flight (TOF) MS (TOF-MS). GC with flame ionization (FI) (GC/FI) and electron impact (EI) MS (GC/EI-MS) has been extensively utilized in the analysis of isoprostanes and other low-molecular-weight oxolipids, although these methods require derivatization of the analytes. In contrast, LC with ultraviolet (UV) absorption (LC/UV) or evaporate light scattering detection (ELSD) (LC/ELSD) as well as electrospray ionization (ESI) or atmospheric pressure chemical ionization (APCI) MS (LC/ESI-MS) or LC/APCI-MS has proven to be well suited for the analysis of intact oxolipids and their conjugates without or with minimal derivatization. Nevertheless, kit-based colorimetric and fluorescent procedures continue to serve as sensitive indicators of the presence of hydroperoxides and aldehydes.
Chen, Tao; Liu, Yongling; Zou, Denglang; Chen, Chen; You, Jinmao; Zhou, Guoying; Sun, Jing; Li, Yulin
2014-01-01
This study presents an efficient strategy based on liquid-liquid extraction, high-speed counter-current chromatography, and preparative HPLC for the rapid enrichment, separation, and purification of four anthraquinones from Rheum tanguticum. A new solvent system composed of petroleum ether/ethyl acetate/water (4:2:1, v/v/v) was developed for the liquid-liquid extraction of the crude extract from R. tanguticum. As a result, emodin, aloe-emodin, physcion, and chrysophanol were greatly enriched in the organic layer. In addition, an efficient method was successfully established to separate and purify the above anthraquinones by high-speed counter-current chromatography and preparative HPLC. This study supplies a new alternative method for the rapid enrichment, separation, and purification of emodin, aloe-emodin, physcione, and chrysophanol. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Vu, Dai Long; Ranglová, Karolína; Hájek, Jan; Hrouzek, Pavel
2018-05-01
Quantification of selenated amino-acids currently relies on methods employing inductively coupled plasma mass spectrometry (ICP-MS). Although very accurate, these methods do not allow the simultaneous determination of standard amino-acids, hampering the comparison of the content of selenated versus non-selenated species such as methionine (Met) and selenomethionine (SeMet). This paper reports two approaches for the simultaneous quantification of Met and SeMet. In the first approach, standard enzymatic hydrolysis employing Protease XIV was applied for the preparation of samples. The second approach utilized methanesulfonic acid (MA) for the hydrolysis of samples, either in a reflux system or in a microwave oven, followed by derivatization with diethyl ethoxymethylenemalonate. The prepared samples were then analyzed by multiple reaction monitoring high performance liquid chromatography tandem mass spectrometry (MRM-HPLC-MS/MS). Both approaches provided platforms for the accurate determination of selenium/sulfur substitution rate in Met. Moreover the second approach also provided accurate simultaneous quantification of Met and SeMet with a low limit of detection, low limit of quantification and wide linearity range, comparable to the commonly used gas chromatography mass spectrometry (GC-MS) method or ICP-MS. The novel method was validated using certified reference material in conjunction with the GC-MS reference method. Copyright © 2018. Published by Elsevier B.V.
Hamscher, Gerd; Mohring, Siegrun A I; Knobloch, Anna; Eberle, Nina; Nau, Heinz; Nolte, Ingo; Simon, Daniela
2010-04-01
Cytotoxic drugs, previously used only in human medicine, are increasingly utilized for cancer treatment in veterinary practice. We developed and validated a liquid chromatography (LC)-electrospray ionization-tandem mass spectrometry (MS-MS) method to determine vincristine, vinblastine, cyclophosphamide, and doxorubicin in canine urine. Sample pretreatment consisted of liquid-liquid extraction, and LC separation was carried out on an RP C(18) column employing a 0.5% formic acid/methanol gradient system. The analytes were detected in positive ion mode using the MS-MS scan mode. The mean recoveries in six different urine samples were between 64.2% and 86.9%. Limits of quantitation were 0.5 microg/L for vincristine and vinblastine, 1 microg/L for cyclophosphamide, and 5 microg/L for doxorubicin; limits of detection were approximately 0.25 microg/L for vincristine, vinblastine, and cyclophosphamide and 0.5 microg/L for doxorubicin. It could be demonstrated that all investigated drugs are found in urine of dogs undergoing chemotherapy. In samples from day 1 after chemotherapy, as much as 63 microg/L vincristine, 111 microg/L vinblastine, and 762 microg/L doxorubicin could be detected. Cyclophosphamide showed only minor concentrations on day 1, but up to 2583 microg/L could be found directly after chemotherapy. These initial data show that there might be a potential contamination risk when administering cytotoxics in veterinary medicine.
Ebrahim, Karim; Poursafa, Parinaz; Amin, Mohammad Mehdi
2017-11-01
A new method was developed for the trace determination of phthalic acid esters in plasma using dispersive liquid-liquid microextraction and gas chromatography with mass spectrometry analysis. Plasma proteins were efficiently precipitated by trichloroacetic acid and then a mixture of chlorobenzene (as extraction solvent) and acetonitrile (as dispersive solvent) rapidly injected to clear supernatant using a syringe. After centrifuging, chlorobenzene sedimented at the bottom of the test tube. 1 μL of this sedimented phase was injected into the gas chromatograph for phthalic acid esters analysis. Different factors affecting the extraction performance, such as the type of extraction and dispersive solvent, their volume, extraction time, and the effects of salt addition were investigated and optimized. Under the optimum conditions, the enrichment factors and extraction recoveries were satisfactory and ranged between 820-1020 and 91-97%, respectively. The linear range was wide (50-1000 ng/mL) and limit of detection was very low (1.5-2.5 ng/mL for all analytes). The relative standard deviations for analysis of 1 μg/mL of the analytes were between 3.2-6.1%. Salt addition showed no significant effect on extraction recovery. Finally, the proposed method was successfully utilized for the extraction and determination of the phthalic acid esters in human plasma samples and satisfactory results were obtained. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Taguchi, Kaori; Fukusaki, Eiichiro; Bamba, Takeshi
2014-10-03
Chromatography techniques usually use a single state in the mobile phase, such as liquid, gas, or supercritical fluid. Chromatographers manage one of these techniques for their purpose but are sometimes required to use multiple methods, or even worse, multiple techniques when the target compounds have a wide range of chemical properties. To overcome this challenge, we developed a single method covering a diverse compound range by means of a "unified" chromatography which completely bridges supercritical fluid chromatography and liquid chromatography. In our method, the phase state was continuously changed in the following order; supercritical, subcritical and liquid. Moreover, the gradient of the mobile phase starting at almost 100% CO2 was replaced with 100% methanol at the end completely. As a result, this approach achieved further extension of the polarity range of the mobile phase in a single run, and successfully enabled the simultaneous analysis of fat- and water-soluble vitamins with a wide logP range of -2.11 to 10.12. Furthermore, the 17 vitamins were exceptionally separated in 4min. Our results indicated that the use of dense CO2 and the replacement of CO2 by methanol are practical approaches in unified chromatography covering diverse compounds. Additionally, this is a first report to apply the novel approach to unified chromatography, and can open another door for diverse compound analysis in a single chromatographic technique with single injection, single column and single system. Copyright © 2014. Published by Elsevier B.V.
DNAPL Dissolution in Bedrock Fractures And Fracture Networks
2011-06-01
were filtered through a 0.2 micron filter and then analyzed via ion chromatography ( Dionex DX-120, Sunnyvale, CA). An additional set of sorption...analyzed via ion chromatography ( Dionex DX-120, Sunnyvale, CA). The effluent pH was monitored periodically with pH test strips. Aqueous DHC...liquid EDTA ethylenediaminetetraacetic acid GC gas chromatograph HPLC high-performance liquid chromatography ISCO in situ chemical oxidation
Exudate Chemical Profiles Derived from Lespedeza and Other Tallgrass Prairie Plant Species
2017-05-01
assayed by liquid chromatography–tandem mass spec- trometry (LC-MS/MS) and gas chromatography/mass spectrometry (GC/MS). The objective was to elucidate...molecular weight compounds were identified via gas chromatography/mass spectrometry (GC/MS) and tentatively identified as benzophenone and 1,4...diacetylbenzene. Three higher molecular weight compounds were identified by liquid chromatography-electrospray ionization- mass spectrometry (LC-ESI-MS
An Inexpensive Liquid Chromatography Apparatus for Undergraduate Teaching.
ERIC Educational Resources Information Center
McCamish, Malcolm; And Others
1982-01-01
Describes an inexpensive, low-pressure liquid chromatography pump, slurry filler, stainless steel columns, and injector system suitable for the undergraduate laboratory or routine analysis. Includes sectional diagram of the pump and construction diagram of the preparative columns. (Author/SK)
Ma, Jing; Hou, Xiaofang; Zhang, Bing; Wang, Yunan; He, Langchong
2014-03-01
In this study, a new"heart-cutting" two-dimensional liquid chromatography method for the simultaneous determination of carbohydrate contents in milk powder was presented. In this two dimensional liquid chromatography system, a Venusil XBP-C4 analysis column was used in the first dimension ((1)D) as a pre-separation column, a ZORBAX carbohydrates analysis column was used in the second dimension ((2)D) as a final-analysis column. The whole process was completed in less than 35min without a particular sample preparation procedure. The capability of the new two dimensional HPLC method was demonstrated in the determination of carbohydrates in various brands of milk powder samples. A conventional one dimensional chromatography method was also proposed. The two proposed methods were both validated in terms of linearity, limits of detection, accuracy and precision. The comparison between the results obtained with the two methods showed that the new and completely automated two dimensional liquid chromatography method is more suitable for milk powder sample because of its online cleanup effect involved. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.
Wang, Yinan; Han, Fei; Song, Aihua; Wang, Miao; Zhao, Min; Zhao, Chunjie
2016-11-01
Cortex Fraxini is an important traditional Chinese medicine. In this work, a rapid and reliable homogenate extraction method was applied for the fast extraction for Cortex Fraxini, and the method was optimized by response surface methodology. Ultra high performance liquid chromatography combined with Fourier transform ion cyclotron resonance mass spectrometry and gas chromatography with mass spectrometry were established for the separation and characterization of the constituents of Cortex Fraxini. Liquid chromatography separation was conducted on a C 18 column (150 mm × 2.1 mm, 1.8 μm), and gas chromatography separation was performed on a capillary with a 5% phenyl-methylpolysiloxane stationary phase (30 m × 0.25 mm × 0.25 mm) by injection of silylated samples. According to the results, 33 chemical compounds were characterized by liquid chromatography with mass spectrometry, and 11 chemical compounds were characterized by gas chromatography with mass spectrometry, and coumarins were the major components characterized by both gas chromatography with mass spectrometry and liquid chromatography with mass spectrometry. The proposed homogenate extraction was an efficient and rapid method, and coumarins, phenylethanoid glycosides, iridoid glycosides, phenylpropanoids, and lignans were the main constituents of Cortex Fraxini. This work laid the foundation for further study of Cortex Fraxini and will be helpful for the rapid extraction and characterization of ingredients in other traditional Chinese medicines. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
ERIC Educational Resources Information Center
Klein, Jessie W.; Patev, Paul
1998-01-01
Presents three experiments to introduce students to different kinds of chromatography: (1) paper chromatography; (2) gel filtration chromatography; and (3) reverse-phase liquid chromatography. Written in the form of a laboratory manual, explanations of each of the techniques, materials needed, procedures, and a glossary are included. (PVD)
Design of analytical systems based on functionality of doped ice.
Okada, Tetsuo
2014-01-01
Ice plays an important role for the circulations of some compounds in the global environment. Both the ice surface and the liquid phase developed in a frozen solution are involved in such reactions of the molecules of environmental importance. This leads to the idea that ice can be used to design novel analytical reaction systems. We devised ice chromatography, in which ice particles are used as the liquid chromatographic stationary phase, and have subsequently developed various analytical systems utilizing the functionality of ice. This review focuses our attention on the analytical facets of ice containing impurities such as salts; hereinafter, we call this "doped ice". The design of novel separation systems and use as microreactors with doped ice are mainly discussed.
High-Performance Liquid Chromatography-Mass Spectrometry.
ERIC Educational Resources Information Center
Vestal, Marvin L.
1984-01-01
Reviews techniques for online coupling of high-performance liquid chromatography with mass spectrometry, emphasizing those suitable for application to nonvolatile samples. Also summarizes the present status, strengths, and weaknesses of various techniques and discusses potential applications of recently developed techniques for combined liquid…
ERIC Educational Resources Information Center
Delaney, Michael F.; And Others
1985-01-01
Describes a simple and reliable new quantitative analysis experiment using liquid chromatography for the determinaiton of caffeine, saccharin, and sodium benzoate in beverages. Background information, procedures used, and typical results obtained are provided. (JN)
NASA Astrophysics Data System (ADS)
Schulzki, G.; Spiegelberg, A.; Bögl, K. W.; Schreiber, G. A.
1995-02-01
For identification of irradiated food, radiation-induced volatile hydrocarbons (HC) are determined by gas chromatography in the non-polar fraction of fat. However, in complex food matrices the detection is often disturbed by fat-associated compounds. On-line coupling of high performance liquid chromatography (LC) and gas chromatography (GC) is very efficient to remove such compounds from the HC fraction. The high sensitivity of this fast and efficient technique is demonstrated by the example of detection of radiation-induced HC in fat isolated from baked sponge cake which had been prepared with irradiated liquid egg.
Messman, J.D.; Rains, T.C.
1981-01-01
A liquid chromatography-atomic absorption spectrometry (LC-AAS) hybrid analytical technique is presented for metal speciation measurements on complex liquid samples. The versatility and inherent metal selectivity of the technique are Illustrated by the rapid determination of five tetraalkyllead compounds in commercial gasoline. Separation of the individual tetraalkyllead species is achieved by reversed-phase liquid chromatography using an acetonitrile/water mobile phase. The effluent from the liquid Chromatograph Is introduced directly into the aspiration uptake capillary of the nebulizer of an air/acetylene flame atomic absorption spectrometer. Spectral interferences due to coeluting hydrocarbon matrix constituents were not observed at the 283.3-nm resonance line of lead used for analysis. Detection limits of this LC-AAS hydrid analytical technique, based on a 20-??L injection, are approximately 10 ng Pb for each tetraalkyllead compound.
Development of quality assurance methods for epoxy graphite prepreg
NASA Technical Reports Server (NTRS)
Chen, J. S.; Hunter, A. B.
1982-01-01
Quality assurance methods for graphite epoxy/prepregs were developed. Liquid chromatography, differential scanning calorimetry, and gel permeation chromatography were investigated. These methods were applied to a second prepreg system. The resin matrix formulation was correlated with mechanical properties. Dynamic mechanical analysis and fracture toughness methods were investigated. The chromatography and calorimetry techniques were all successfully developed as quality assurance methods for graphite epoxy prepregs. The liquid chromatography method was the most sensitive to changes in resin formulation. The were also successfully applied to the second prepreg system.
Chen, Der-Yuan; Chen, Yi-Ming; Chien, Han-Ju; Lin, Chi-Chen; Hsieh, Chia-Wei; Chen, Hsin-Hua; Hung, Wei-Ting; Lai, Chien-Chen
2016-01-01
Liquid chromatography/mass spectrometry (LC/MS)-based comprehensive analysis of metabolic profiles with metabolomics approach has potential diagnostic and predictive implications. However, no metabolomics data have been reported in adult-onset Still's disease (AOSD). This study investigated the metabolomic profiles in AOSD patients and examined their association with clinical characteristics and disease outcome. Serum metabolite profiles were determined on 32 AOSD patients and 30 healthy controls (HC) using ultra-performance liquid chromatography (UPLC)/MS analysis, and the differentially expressed metabolites were quantified using multiple reactions monitoring (MRM)/MS analysis in 44 patients and 42 HC. Pure standards were utilized to confirm the presence of the differentially expressed metabolites. Eighteen differentially expressed metabolites were identified in AOSD patents using LC/MS-based analysis, of which 13 metabolites were validated by MRM/MS analysis. Among them, serum levels of lysoPC(18:2), urocanic acid and indole were significantly lower, and L-phenylalanine levels were significantly higher in AOSD patients compared with HC. Moreover, serum levels of lysoPC(18:2), PhePhe, uridine, taurine, L-threonine, and (R)-3-Hydroxy-hexadecanoic acid were significantly correlated with disease activity scores (all p<0.05) in AOSD patients. A different clustering of metabolites was associated with a different disease outcome, with significantly lower levels of isovalerylsarcosine observed in patients with chronic articular pattern (median, 77.0AU/ml) compared with monocyclic (341.5AU/ml, p<0.01) or polycyclic systemic pattern (168.0AU/ml, p<0.05). Thirteen differentially expressed metabolites identified and validated in AOSD patients were shown to be involved in five metabolic pathways. Significant associations of metabolic profiles with disease activity and outcome of AOSD suggest their involvement in AOSD pathogenesis.
Robandt, Paul P; Reda, Louis J; Klette, Kevin L
2008-10-01
A fully automated system utilizing a liquid handler and an online solid-phase extraction (SPE) device coupled with liquid chromatography-tandem mass spectrometry (LC-MS-MS) was designed to process, detect, and quantify benzoylecgonine (BZE), meta-hydroxybenzoylecgonine (m-OH BZE), para-hydroxybenzoylecgonine (p-OH BZE), and norbenzoylecgonine (nor-BZE) metabolites in human urine. The method was linear for BZE, m-OH BZE, and p-OH BZE from 1.2 to 10,000 ng/mL with limits of detection (LOD) and quantification (LOQ) of 1.2 ng/mL. Nor-BZE was linear from 5 to 10,000 ng/mL with an LOD and LOQ of 1.2 and 5 ng/mL, respectively. The intrarun precision measured as the coefficient of variation of 10 replicates of a 100 ng/mL control was less than 2.6%, and the interrun precision for 5 replicates of the same control across 8 batches was less than 4.8% for all analytes. No assay interference was noted from controls containing cocaine, cocaethylene, and ecgonine methyl ester. Excellent data concordance (R2 > 0.994) was found for direct comparison of the automated SPE-LC-MS-MS procedure and an existing gas chromatography-MS procedure using 94 human urine samples previously determined to be positive for BZE. The automated specimen handling and SPE procedure, when compared to the traditional extraction schema, eliminates the human factors of specimen handling, processing, extraction, and derivatization, thereby reducing labor costs and rework resulting from batch handling issues, and may reduce the number of fume hoods required in the laboratory.
Alghazi, Mansoor; Alanazi, Fars; Mohsin, Kazi; Siddiqui, Nasir Ali; Shakeel, Faiyaz; Haq, Nazrul
2017-04-01
Statins in combination with fibrates show beneficial effects on the lipoprotein profile of patients because they have positive complimentary effects on lipid profile. A new green ultrahigh-performance liquid chromatography-diode array detector method for simultaneous analysis of simvastatin (SMV) and fenofibrate (FNF) in standard form, marketed formulations, and self-emulsifying drug delivery system formulations was developed and validated in the present investigation. The method utilized C 18 as stationary phase and a combination of methanol:water (8:2) as an eluent. It was found that selected eluent provided short run time (2.5 minutes), better peak symmetry and satisfactory values of other chromatographic parameters such as resolution (Rs=2.325), capacity factor (k, 3.0 and 4.2 for SMV and FNF, respectively), selectivity (α =1.4), and number of theoretical plates (N, 4265 and 5285 for SMV and FNF, respectively). An excellent linear relationship (r 2 0.998 and 0.997 for SMV and FNF, respectively) was observed for linear regression data for the calibration plots. The developed system was validated for accuracy, precision, robustness (˃ 2% for both drugs) and recovery (98-102% for both drugs). Results obtained from the statistical treatment of the values obtained for different parameters proved that the method is suitable, reproducible, and selective for the simultaneous analysis of SMV and FNF in bulk, marketed, and self-emulsifying drug delivery system formulations. The replacement of commonly applied toxic solvents with innocuous and environmentally benign solvents provides a better option than the more toxic processes in drug analysis. Copyright © 2016. Published by Elsevier B.V.
Zhu, Yang; Morisato, Kei; Hasegawa, George; Moitra, Nirmalya; Kiyomura, Tsutomu; Kurata, Hiroki; Kanamori, Kazuyoshi; Nakanishi, Kazuki
2015-08-01
The optimization of a porous structure to ensure good separation performances is always a significant issue in high-performance liquid chromatography column design. Recently we reported the homogeneous embedment of Ag nanoparticles in periodic mesoporous silica monolith and the application of such Ag nanoparticles embedded silica monolith for the high-performance liquid chromatography separation of polyaromatic hydrocarbons. However, the separation performance remains to be improved and the retention mechanism as compared with the Ag ion high-performance liquid chromatography technique still needs to be clarified. In this research, Ag nanoparticles were introduced into a macro/mesoporous silica monolith with optimized pore parameters for high-performance liquid chromatography separations. Baseline separation of benzene, naphthalene, anthracene, and pyrene was achieved with the theoretical plate number for analyte naphthalene as 36,000 m(-1). Its separation function was further extended to cis/trans isomers of aromatic compounds where cis/trans stilbenes were chosen as a benchmark. Good separation of cis/trans-stilbene with separation factor as 7 and theoretical plate number as 76,000 m(-1) for cis-stilbene was obtained. The trans isomer, however, is retained more strongly, which contradicts the long- established retention rule of Ag ion chromatography. Such behavior of Ag nanoparticles embedded in a silica column can be attributed to the differences in the molecular geometric configuration of cis/trans stilbenes. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Tsyurupa, M. P.; Blinnikova, Z. K.; Il'in, M. M.; Davankov, V. A.; Parenago, O. O.; Pokrovskii, O. I.; Usovich, O. I.
2015-11-01
Monodisperse styrene-divinylbenzene (1 wt %) copolymer microbeads are obtained via the elaborate method of high-productivity precipitation polymerization. The crosslinking of this copolymer with chloromethyl methyl ether in the presence of Friedel-Crafts catalyst yields porous hypercrosslinked polymers with degrees of crosslinking that range from 200 to 500%. Microbead sorbents are shown to be suited for selective stationary phases for high-performance liquid chromatography and supercritical fluid chromatography.
Rubinfeld, Bonnee; Leif, Roald; Mulcahy, Heather; Dugan, Lawrence; Souza, Brian
2018-01-01
Biosurfactants have several desirable characteristics in the industrial sector: detergency, antimicrobial effects, skin hydration, and emulsibility. Several yeast glycolipids are currently being utilized in these capacities: sophorolipids, ustilagic acid, and mannosylerythritol lipids (MELs). An emerging class of glycolipids, termed polyol esters of fatty acids (PEFA), have recently been reported for Rhodotorula babjevae, a basidiomycetous yeast species that secretes hyperacetylated congeners of PEFA (typically with 3–6 acetylation modifications). While screening Rhodotorula species for surfactant production, we identified a new environmental isolate identified as Rhodotorula taiwanensis MD1149 that dropped the surface tension of the liquid medium, indicating that it produced a potent biosurfactant. Acid depolymerization of the purified biosurfactants, followed by gas chromatography-mass spectrometry (GC-MS) analysis revealed that the biosurfactants were composed of PEFA compounds composed mainly of mannitol and arabitol esters of 3-hydroxy fatty acid, 3-methoxy fatty acid, and fatty acids with a single double bond; chain lengths were mainly C16 and C18. Liquid chromatography-mass spectrometry (LC-MS) confirmed the predicted accurate mass of these compounds. Interestingly, PEFA compounds produced by Rhodotorula taiwanensis MD1149 were more surface active due to their hypoacetylation profile (0–4 acetylation modifications) compared to Rhodotorula babjevae MD1169. These disparate surface active properties, based on acetylation, change the hydrophilic-lipophilic balance (HLB) of these compounds, and their potential utility within industrial applications. PMID:29293588
Nesterenko, Pavel N; Rybalko, Marina A; Paull, Brett
2005-06-01
Significant deviations from classical van Deemter behaviour, indicative of turbulent flow liquid chromatography, has been recorded for mobile phases of varying viscosity on porous silica monolithic columns at elevated mobile phase flow rates.
Determination of Caffeine in Beverages by High Performance Liquid Chromatography.
ERIC Educational Resources Information Center
DiNunzio, James E.
1985-01-01
Describes the equipment, procedures, and results for the determination of caffeine in beverages by high performance liquid chromatography. The method is simple, fast, accurate, and, because sample preparation is minimal, it is well suited for use in a teaching laboratory. (JN)
A qualitative method using 2,4-dinitrophenylhydrazine (DNPH) derivatization followed by analysis with liquid chromatography (LC)/negative ion-electrospray mass spectrometry (MS) was developed for identifying polar aldehydes and ketones in ozonated drinking water. This method offe...
Akimoto, Masaru; Hokazono, Eisaku; Ota, Eri; Tateishi, Takiko; Kayamori, Yuzo
2016-01-01
Tamm-Horsfall protein (also known as uromodulin) is the most abundant urinary protein in healthy individuals. Since initially characterized by Tamm and Horsfall, the amount of urinary excretion and structural mutations of Tamm-Horsfall protein is associated with kidney diseases. However, currently available assays for Tamm-Horsfall protein, which are mainly enzyme-linked immunosorbent assay-based, suffer from poor reproducibility and might give false negative results. We developed a novel, quantitative assay for Tamm-Horsfall protein using reversed-phase high-performance liquid chromatography. A precipitation pretreatment avoided urine matrix interference and excessive sample dilution. High-performance liquid chromatography optimization based on polarity allowed excellent separation of Tamm-Horsfall protein from other major urine components. Our method exhibited high precision (based on the relative standard deviations of intraday [≤2.77%] and interday [≤5.35%] repetitions). The Tamm-Horsfall protein recovery rate was 100.0-104.2%. The mean Tamm-Horsfall protein concentration in 25 healthy individuals was 31.6 ± 18.8 mg/g creatinine. There was a strong correlation between data obtained by high-performance liquid chromatography and enzyme-linked immunosorbent assay (r = 0.906), but enzyme-linked immunosorbent assay values tended to be lower than high-performance liquid chromatography values at low Tamm-Horsfall protein concentrations. The high sensitivity and reproducibility of our Tamm-Horsfall protein assay will reduce the number of false negative results of the sample compared with enzyme-linked immunosorbent assay. Moreover, our method is superior to other high-performance liquid chromatography methods, and a simple protocol will facilitate further research on the physiological role of Tamm-Horsfall protein. © The Author(s) 2015.
Doshi, Gaurav Mahesh; Une, Hemant Devidas
2016-01-01
In Indian Ayurvedic system, Benincasa hispida (BH) and Carissa congesta (CC) are well-known plants used for major and minor ailments. BH has been regarded as Kushmanda, whereas CC has been used in immune-related disorders of the human system. Quercetin and rutin identified from the vast plethora of plant extracts have proved to possess ethnopharmacological relevance. In present studies, we have determined quercetin and rutin in terms of percentage in BH seeds and CC roots by high-performance thin layer chromatography (HPTLC) and high-performance liquid chromatography (HPLC). After extraction and phytochemical screening, the extracts were subjected to quantification for the presence of quercetin and rutin by HPTLC and HPLC. HPTLC showed quercetin as 44.60, 27.13% and rutin as 32.00, 36.31% w/w, whereas HPLC revealed quercetin as 34.00, 35.00% and rutin as 21.99, 45.03% w/v in BH and CC extracts, respectively. The BH and CC extracts have elucidated peaks that were corresponding with standard peaks on undertaking chromatographic studies. Quercetin and rutin are isolated from BH seeds and CC roots by High Performance. Thin Layer Chromatography and High Performance Liquid Chromatography. HPTLC revealed presence of quercetin as 44.60, 27.13 % and rutin as 32.00, 36.31 % w/w. HPLC revealed presence of quercetin as 34.00, 35.00 % and rutin as 21.99, 45.03 % w/v. Abbreviation Used: HPTLC: High Performance Thin Layer Chromatography; HPLC: High Pressure Liquid Chromatography, UV: Ultraviolet, CC: Carissa congesta, BH: Benincasa hispida.
Zhou, Xuan; Chen, Cen; Ye, Xiaolan; Song, Fenyun; Fan, Guorong; Wu, Fuhai
2016-04-01
In this study, a method coupling turbulent flow chromatography with online solid-phase extraction and high-performance liquid chromatography with tandem mass spectrometry was developed for analyzing the lignans in Magnoliae Flos. By the online pretreatment of turbulent flow chromatography solid-phase extraction, the impurities removal and analytes concentration were automatically processed, and the lignans were separated rapidly and well. Seven lignans of Magnoliae Flos including epieudesmin, magnolin, 1-irioresinol-B-dimethyl ether, epi-magnolin, fargesin aschantin, and demethoxyaschantin were identified by comparing their retention behavior, UV spectra, and mass spectra with those of reference substances or literature data. The developed method was validated, and the good results showed that the method was not only automatic and rapid, but also accurate and reliable. The turbulent flow chromatography with online solid-phase extraction and high-performance liquid chromatography with tandem mass spectrometry method holds a high potential to become an effective method for the quality control of lignans in Magnoliae Flos and a useful tool for the analysis of other complex mixtures. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
LCEC: The Combination of Liquid Chromatography and Electrochemistry.
ERIC Educational Resources Information Center
Kissinger, Peter T.
1983-01-01
Use of combined liquid chromatography and finite-current electrochemistry (LCEC) procedures are discussed. Also discusses the relationship between electroactivity and molecular structure, selectivity in LCEC, and LCEC applications. Because of its selectivity and low detection limits, the procedures are most often applied in biomedical and…
Thurman, E.M.; Malcolm, R.L.
1979-01-01
A scheme is presented which used adsorption chromatography with pH gradient elution and size-exclusion chromatography to concentrate and separate hydrophobic organic acids from water. A review of chromatographic processes involved in the flow scheme is also presented. Organic analytes which appear in each aqueous fraction are quantified by dissolved organic carbon analysis. Hydrophobic organic acids in a water sample are concentrated on a porous acrylic resin. These acids usually constitute approximately 30-50 percent of the dissolved organic carbon in an unpolluted water sample and are eluted with an aqueous eluent (dilute base). The concentrate is then passed through a column of polyacryloylmorpholine gel, which separates the acids into high- and low-molecular-weight fractions. The high- and low-molecular-weight eluates are reconcentrated by adsorption chromatography, then are eluted with a pH gradient into strong acids (predominately carboxylic acids) and weak acids (predominately phenolic compounds). For standard compounds and samples of unpolluted waters, the scheme fractionates humic substances into strong and weak acid fractions that are separated from the low molecular weight acids. A new method utilizing conductivity is also presented to estimate the acidic components in the methanol fraction.
Ichikawa, Akio; Ono, Hiroshi; Furuta, Kenjiro; Shiotsuki, Takahiro; Shinoda, Tetsuro
2007-08-17
Juvenile hormone III (JH III) racemate was prepared from methyl (2E,6E)-farnesoate via epoxidation with 3-chloroperbenzoic acid (mCPBA). Enantioselective separation of JH III was conducted using normal-phase high-performance liquid chromatography (HPLC) on a chiral stationary phase. [(2)H(3)]Methyl (2E,6E)-farnesoate was also prepared from (2E,6E)-farnesoic acid and [(2)H(4)]methanol (methanol-d(4)) using 1-(3-dimethylaminopropyl)-3-ethylcarbodiimide hydrochloride (EDC) and 4-dimethylaminopyridine (DMAP); the conjugated double bond underwent isomerization to some degree. Epoxidation of [(2)H(3)]methyl (2E,6E)-farnesoate with mCPBA gave a novel deuterium-substituted internal standard [(2)H(3)]JH III (JH III-d(3)). The standard curve was produced by linear regression using the peak area ratios of JH III and JH III-d(3) in liquid chromatography-mass spectrometry (LC-MS).
Stebounova, Larissa; Ebert, Scott M; Murry, Logan T; Adams, Christopher M; Murry, Daryl J
2018-04-26
Ultra-performance liquid chromatography (UPLC) interfaced with atmospheric pressure chemical ionization mass-spectrometry was used to separate and quantify ursolic acid (UA) and oleanolic acid (OA) in human plasma. UA and OA were extracted from 0.5 mL human plasma using supported liquid extraction and separated utilizing an Acquity UPLC HSS column. The method has been validated for both UA and OA quantitation with a limit of detection of 0.5 ng/mL. The UPLC separations are carried out with isocratic elution with methanol and 5 mM ammonium acetate in water (85:15) as a mobile phase at a flow rate of 0.4 mL/min. The assay was linear from 1 ng/mL to 100 ng/mL for both analytes. The total analysis time was 7 min with the retention times of 3.25 (internal standard), 3.65 (UA) and 3.85 min (OA). Recovery of drug from plasma ranged from 70% to 115%. Analysis of quality control samples at 3, 30 and 80 ng/mL (n = 14) had an intra-day coefficient of variation of 9.9%, 4.3% and 5.5%, respectively. A proof-of-concept study in human patients who consumed apple peels indicates that this analytical method could be applied to clinical studies of UA and/or OA in human subjects.
Wei, Fang; Hu, Na; Lv, Xin; Dong, Xu-Yan; Chen, Hong
2015-07-24
In this investigation, off-line comprehensive two-dimensional liquid chromatography-atmospheric pressure chemical ionization mass spectrometry using a single column has been applied for the identification and quantification of triacylglycerols in edible oils. A novel mixed-mode phenyl-hexyl chromatographic column was employed in this off-line two-dimensional separation system. The phenyl-hexyl column combined the features of traditional C18 and silver-ion columns, which could provide hydrophobic interactions with triacylglycerols under acetonitrile conditions and can offer π-π interactions with triacylglycerols under methanol conditions. When compared with traditional off-line comprehensive two-dimensional liquid chromatography employing two different chromatographic columns (C18 and silver-ion column) and using elution solvents comprised of two phases (reversed-phase/normal-phase) for triacylglycerols separation, the novel off-line comprehensive two-dimensional liquid chromatography using a single column can be achieved by simply altering the mobile phase between acetonitrile and methanol, which exhibited a much higher selectivity for the separation of triacylglycerols with great efficiency and rapid speed. In addition, an approach based on the use of response factor with atmospheric pressure chemical ionization mass spectrometry has been developed for triacylglycerols quantification. Due to the differences between saturated and unsaturated acyl chains, the use of response factors significantly improves the quantitation of triacylglycerols. This two-dimensional liquid chromatography-mass spectrometry system was successfully applied for the profiling of triacylglycerols in soybean oils, peanut oils and lord oils. A total of 68 triacylglycerols including 40 triacylglycerols in soybean oils, 50 triacylglycerols in peanut oils and 44 triacylglycerols in lord oils have been identified and quantified. The liquid chromatography-mass spectrometry data were analyzed using principal component analysis. The results of the principal component analysis enabled a clear identification of different plant oils. By using this two-dimensional liquid chromatography-mass spectrometry system coupled with principal component analysis, adulterated soybean oils with 5% added lord oil and peanut oils with 5% added soybean oil can be clearly identified. Copyright © 2015 Elsevier B.V. All rights reserved.
Otabe, Shuichi; Nakayama, Hitomi; Ohki, Tsuyoshi; Soejima, Eri; Tajiri, Yuji; Yamada, Kentaro
2017-07-01
Background We aimed to determine whether the discrepancy between haemoglobin A1c values determined by high-performance liquid chromatography and enzymatic haemoglobin A1c measurements in diabetic patients was clinically relevant. Methods We randomly recruited 1421 outpatients undergoing diabetic treatment and follow-up who underwent at least three haemoglobin A1c measurements between April 2014 and March 2015 at our clinic. In 6369 samples, haemoglobin A1c was simultaneously measured by HA-8160 and MetaboLead (enzymatic assay), and the values were compared. Results haemoglobin A1c measurements by high-performance liquid chromatography and enzymatic assay were strongly correlated (correlation coefficient: 0.9828, linear approximation curve y = 0.9986x - 0.2507). Mean haemoglobin A1c (6.8 ± 1.0%) measured by high-performance liquid chromatography was significantly higher than that measured by enzymatic assay (6.5 ± 1.0%, P < 0.0001). During the sample processing, four (0.3%) subjects presented consistently lower haemoglobin A1c values (<0.7%) by high-performance liquid chromatography than those from enzymatic assay. Of these, three had Hb Toranomon [β112 (G14) Cys→Trp]. The fourth had Hb Ube-2 [α68 (E17) Asn→Asp]. One other subject presented consistently higher haemoglobin A1c values (>1%) by high-performance liquid chromatography than those from enzymatic assay and was diagnosed with a -77 (T > C) mutation in the δ-globin gene. These unrelated asymptomatic subjects had normal erythrocyte profiles, without anaemia. Conclusions We showed that haemoglobin A1c values measured by high-performance liquid chromatography were significantly higher than those measured by enzymatic assay in diabetic subjects. However, when an oversized deviation (>0.7%) between glycaemic control status and haemoglobin A1c is apparent, clinicians should check the methods used to measure haemoglobin A1c and consider the possible presence of a haemoglobin variant.
Gu, Qun; David, Frank; Lynen, Frédéric; Vanormelingen, Pieter; Vyverman, Wim; Rumpel, Klaus; Xu, Guowang; Sandra, Pat
2011-05-20
Ionic liquid stationary phases were tested for one dimensional gas chromatography-mass spectrometry (GC-MS) and comprehensive two dimensional gas chromatography (GC×GC) of fatty acid methyl esters from algae. In comparison with polyethylene glycol and cyanopropyl substituted polar stationary phases, ionic liquid stationary phases SLB-IL 82 and SLB-IL 100 showed comparable resolution, but lower column bleeding with MS detection, resulting in better sensitivity. The selectivity and polarity of the ionic liquid phases are similar to a highly polar biscyanopropyl-silicone phase (e.g. HP-88). In GC×GC, using an apolar polydimethyl siloxane×polar ionic liquid column combination, an excellent group-type separation of fatty acids with different carbon numbers and number of unsaturations was obtained, providing information that is complementary to GC-MS identification. Copyright © 2011 Elsevier B.V. All rights reserved.
Yilmaz, Bilal; Asci, Ali; Kucukoglu, Kaan; Albayrak, Mevlut
2016-08-01
A simple high-performance liquid chromatography method has been developed for the determination of formaldehyde in human tissue. FA Formaldehyde was derivatized with 2,4-dinitrophenylhydrazine. It was extracted from human tissue with ethyl acetate by liquid-liquid extraction and analyzed by high-performance liquid chromatography. The calibration curve was linear in the concentration range of 5.0-200 μg/mL. Intra- and interday precision values for formaldehyde in tissue were <6.9%, and accuracy (relative error) was better than 6.5%. The extraction recoveries of formaldehyde from human tissue were between 88 and 98%. The limits of detection and quantification of formaldehyde were 1.5 and 5.0 μg/mL, respectively. Also, this assay was applied to liver samples taken from a biopsy material. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Wu, Datong; Cai, Pengfei; Zhao, Xiaoyong; Kong, Yong; Pan, Yuanjiang
2018-01-01
Ionic liquids have been functionalized for modern applications. The functional ionic liquids are also called task-specific ionic liquids. Various task-specific ionic liquids with certain groups have been constructed and exploited widely in the field of separation. To take advantage of their properties in separation science, task-specific ionic liquids are generally used in techniques such as liquid-liquid extraction, solid-phase extraction, gas chromatography, high-performance liquid chromatography, and capillary electrophoresis. This review mainly covers original research papers published in the last five years, and we will focus on task-specific ionic liquids as the chiral selectors in chiral resolution and as extractant or sensor for biological samples and metal ion purification. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Zou, Denglang; Chen, Tao; Chen, Chen; Li, Hongmei; Liu, Yongling; Li, Yulin
2016-08-01
In this article, macroporous resin column chromatography and preparative high-performance liquid chromatography were applied for preparation of gallic acid from Terminalia bellirica (Gaertn.) Roxb. In the first step, six kinds of resins were investigated by adsorption and desorption tests and AB-8 macroporous resin was selected for the enrichment of gallic acid. As a result, 20 g of gallic acid at a purity of 71% could be separated from 100 g of crude extract in which the content of gallic acid was 16.7% and the recovery of gallic acid reached 85.0%. In the second step, preparative high-performance liquid chromatography was selected to purify gallic acid. As a result, 640 mg of gallic acid at a purity of 99.1% was obtained from 1 g of sample in 35 min. The results demonstrated that macroporous resin coupled with preparative high-performance liquid chromatography was suitable for preparation of gallic acid from T. bellirica (Gaertn.) Roxb. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Terry, Paul H.; Aung, Louis H.; De Hertogh, August A.
1982-01-01
A major growth inhibitory substance of tulip bulbs (Tulipa gesneriana L. cv Paul Richter) has been unequivocally shown to be abscisic acid (ABA). The ABA methyl ester of the free ether-soluble acid fractions of tulip organs had the identical retention time on gas-liquid chromatography with electron capture detector as authentic ABA methyl ester. In addition, the mass spectra were the same. On a unit dry matter basis, the basalplate and floral shoot contained 3.6 and 2.6 times more ABA than the fleshy scales, respectively. PMID:16662721
Gianfrilli, P; Pantosti, A; Luzzi, I
1985-01-01
Direct gas-liquid chromatography of faecal specimens with isocaproic acid as a marker was used for the rapid diagnosis of Clostridium difficile associated diarrhoeal diseases. Ninety stools were examined and results were compared with conventional culture on selective medium and cytotoxin assay in tissue culture. Using a combined analysis of isocaproic acid and butyric acid peak heights we defined three categories: positive, negative, and indeterminate. When the indeterminate group was excluded, the positive and negative predictive values of gas-liquid chromatography analysis were 86.9% and 85% respectively compared with culture and 71.4% and 95% respectively compared with cytotoxin assay. PMID:4008667
High-performance liquid chromatography of oligoguanylates at high pH
NASA Technical Reports Server (NTRS)
Stribling, R.; Deamer, D. (Principal Investigator)
1991-01-01
Because of the stable self-structures formed by oligomers of guanosine, standard high-performance liquid chromatography techniques for oligonucleotide fractionation are not applicable. Previously, oligoguanylate separations have been carried out at pH 12 using RPC-5 as the packing material. While RPC-5 provides excellent separations, there are several limitations, including the lack of a commercially available source. This report describes a new anion-exchange high-performance liquid chromatography method using HEMA-IEC BIO Q, which successfully separates different forms of the guanosine monomer as well as longer oligoguanylates. The reproducibility and stability at high pH suggests a versatile role for this material.
Gas-liquid chromatography with a volatile "stationary" liquid phase.
Wells, P S; Zhou, S; Parcher, J F
2002-05-01
A unique type of gas-liquid chromatography is described in which both mobile and "stationary" phases are composed of synthetic mixtures of helium and carbon dioxide. At temperatures below the critical point of the binary mixture and pressures above the vapor pressure of pure liquid carbon dioxide, helium and carbon dioxide can form two immiscible phases over extended composition ranges. A binary vapor phase enriched in helium can act as the mobile phase for chromatographic separations, whereas a CO2-rich liquid in equilibrium with the vapor phase, but condensed on the column wall, can act as a pseudostationary phase. Several examples of chromatographic separations obtained in "empty" capillary columns with no ordinary stationary liquid phase illustrate the range of conditions that produce such separations. In addition, several experiments are reported that confirm the proposed two-phase hypothesis. The possible consequences of the observed chromatographic phenomenon in the field of supercritical fluid chromatography with helium headspace carbon dioxide are discussed.
NASA Astrophysics Data System (ADS)
Sun, Xueping; Wang, Man; Liu, Buming; Sun, Zhenliang
2017-10-01
Three angiotensin I converting enzyme (ACE) inhibition peptides were isolated from sandworm Sipunculus nudus protein hydrolysate prepared using protamex. Consecutive purification methods, including size exclusion chromatography and reverse-phase high performance liquid chromatography (RP-HPLC), were used to isolate the ACE inhibition peptides. The amino acid sequences of the peptides were identified as Ile-Asn-Asp, Val-Glu-Pro-Gly and Leu-Ala-Asp-Glu-Phe. The IC50 values of the purified peptides for ACE inhibition activity were 34.72 μmol L-1, 20.55 μmol L-1 and 22.77 μmol L-1, respectively. These results suggested that S. nudus proteins contain specific peptides that can be released by enzymatic hydrolysis. This study may provide an experimental basis for further systematic research, rational development and clinical utilization of sandworm resources.
Abourashed, Ehab A.; Fu, Hao Wen
2017-01-01
Borututu (Cochlospermum angolensis) is an African tree whose bark has recently emerged as a herbal dietary supplement with claims for antioxidant activity. In order to substantiate the claimed activity of borututu supplements, we performed an activity-guided fractionation of the total extract utilizing a 1,1-diphenyl-2-picrylhydrazyl (DPPH) free radical scavenging assay. Subsequent flash and centrifugal chromatography resulted in the isolation of gallic acid (1) and protocatechuic acid (2) as the main antioxidant constituents. Two apocarotenoids and one flavonoid were also isolated from the chloroform fraction and were identified as cochloxanthin (3), dihydrocochloxanthin (4), and 7,4′-dimethyltaxifolin (5), respectively. A High-performance liquid chromatography (HPLC) method was also developed for fingerprinting borututu samples, with Compounds 1–4 suggested as chemical markers for quality control purposes. PMID:28134834
This research was conducted in cooperation with EPA Region 4 in Athens, GA to develop a method to analyze selected pyrethroid pesticides using Reverse Phase-High Pressure Liquid Chromatography (HPLC). This HPLC method will aid researchers in separating and identifying these py...
This document is a standardized single laboratory validated liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the detection and quantification of cyanotoxins (combined intracellular and extracellular) in ambient freshwaters.
ERIC Educational Resources Information Center
Bailey, Leonard
1978-01-01
The experiment described was developed for the third-year course in inorganic and analytical pharmaceutical chemistry to provide students with "hands-on" experience with high pressure liquid chromatography. Assay procedures are given along with experimental parameters and student results. (LBH)
Multichannel Detection in High-Performance Liquid Chromatography.
ERIC Educational Resources Information Center
Miller, James C.; And Others
1982-01-01
A linear photodiode array is used as the photodetector element in a new ultraviolet-visible detection system for high-performance liquid chromatography (HPLC). Using a computer network, the system processes eight different chromatographic signals simultaneously in real-time and acquires spectra manually/automatically. Applications in fast HPLC…
Mallow carotenoids determined by high-performance liquid chromatography
USDA-ARS?s Scientific Manuscript database
Mallow (corchorus olitorius) is a green vegetable, which is widely consumed either fresh or dry by Middle East population. This study was carried out to determine the contents of major carotenoids quantitatively in mallow, by using a High Performance Liquid Chromatography (HPLC) equipped with a Bis...
Ionic Liquids in HPLC and CE: A Hope for Future.
Ali, Imran; Suhail, Mohd; Sanagi, Mohd Marsin; Aboul-Enein, Hassan Y
2017-07-04
The ionic liquids (ILs) are salts with melting points below 100°C. These are called as ionic fluids, ionic melts, liquid electrolytes, fused salts, liquid salts, ionic glasses, designer solvents, green solvents and solvents of the future. These have a wide range of applications, including medical, pharmaceutical and chemical sciences. Nowadays, their use is increasing greatly in separation science, especially in chromatography and capillary electrophoresis due to their remarkable properties. The present article describes the importance of ILs in high-performance liquid chromatography and capillary electrophoresis. Efforts were also made to highlight the future expectations of ILs.
Brede, Cato; Pedersen-Bjergaard, Stig
2004-09-24
This review article presents an overview of halogen-specific detection in gas chromatography (GC) and liquid chromatography (LC). Attention is primarily focused on the use of plasma emission spectroscopy and plasma mass spectrometry as detectors, but other halogen-selective detection principles are also mentioned. Different instrumental configurations are discussed both with respect to technical set-up and performance, the principal reasons for halogen-selective detection are highlighted, and recent applications are reviewed from areas such as environmental chemistry, petroleum characterization, and drug analysis.
Trends in Analytical Scale Separations.
ERIC Educational Resources Information Center
Jorgenson, James W.
1984-01-01
Discusses recent developments in the instrumentation and practice of analytical scale operations. Emphasizes detection devices and procedures in gas chromatography, liquid chromatography, electrophoresis, supercritical fluid chromatography, and field-flow fractionation. (JN)
Wang, Yifan; Li, Haiyan; Yang, Zhen; Zhang, Weijie; Hua, Jia
2017-12-01
To explore why the use of furfural as a transformer oil-paper insulation aging characteristic is problematic in real world application, we developed a method for the simultaneous determination of furfural, furoic acid, and maleic acid in transformer oil by reversed-phase vortex-assisted liquid-liquid microextraction combined with high-performance liquid chromatography. The conditions for the proposed method were optimized, and the obtained extract can be directly analyzed by high-performance liquid chromatography. The detection limits (signal-to-noise ratio = 3) of the method ranged from 1.0 to 4.6 μg/L, the enrichment factors for furfural, furoic acid, maleic acid, and fumaric acid were 4.6, 25.1, 15.6, and 17.5, respectively, and the recovery rates for three analytes (fumaric acid was undetected) range from 82.1 to 106.2%. The contents of furfural, furoic acid, and maleic acid resulted from accelerated aging of transformer insulation oil-paper were measured using the present method for the first time, and the aging samples were analyzed by liquid chromatography with mass spectrometry for the identification of furoic acid and maleic acid in the aging transformer oil samples. Using the optimal method, the target products of samples at different aging time were tracked and measured. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Direct probing of chromatography columns by laser-induced fluorescence
NASA Astrophysics Data System (ADS)
McGuffin, V. L.
1992-12-01
This report summarizes the progress and accomplishments of this research project from 1 Sep. 1989 to 28 Feb. 1993. During this period, we have accomplished all of the primary scientific objectives of the research proposal: (1) constructed and evaluated a laser-induced fluorescence detection system that allows direct examination of the chromatographic column, (2) examined nonequilibrium processes that occur upon solute injection and elution, (3) examined solute retention in liquid chromatography as a function of temperature and pressure, (4) examined solute zone dispersion in liquid chromatography as a function of temperature and pressure, and (5) developed appropriate theoretical models to describe these phenomena. In each of these studies, substantial knowledge has been gained of the fundamental processes that are responsible for chromatographic separations. In addition to these primary research objectives, we have made significant progress in three related areas: (1) examined pyrene as a fluorescent polarity probe in supercritical fluids and liquids as a function of temperature and pressure, (2) developed methods for the class-selective identification of polynuclear aromatic hydrocarbons in coal-derived fluids by microcolumn liquid chromatography with fluorescence quenching detection, and (3) developed methods for the determination of saturated and unsaturated (including omega-3) fatty acids in fish oil extracts by microcolumn liquid chromatography with laser-induced fluorescence detection. In these studies, the advanced separation and detection techniques developed in our laboratory are applied to practical problems of environmental and biomedical significance.
Zou, Nan; Chen, Ronghua; Qin, Yuhong; Song, Shuangyu; Tang, Xinglin; Pan, Canping
2016-09-01
Analytical methods based on multiplug filtration cleanup coupled with pulse glow discharge-ion mobility spectrometry and liquid chromatography tandem mass spectrometry were developed for the analysis of tricaine mesylate residue in fish and fish-raising water samples. A silica fiber holder and an appropriate new interface were designed to make the direct introduction of the fiber into the pulse glow discharge-ion mobility spectrometry introduction mechanism. The multiplug filtration cleanup method with adsorption mixtures was optimized for the determination of tricaine mesylate in fish samples. Good linear relationships were obtained by the two methods. For fish samples, limits of detection were 6 and 0.6 μg/kg by ion mobility spectrometry and liquid chromatography with tandem mass spectrometry, respectively. The matrix effect of the established liquid chromatography tandem mass spectrometry method was negligible for fish samples but that of the ion mobility spectrometry method was not. The two methods were compared. The ion mobility spectrometry system could be used a rapid screening tool on site with the advantage of rapidity, simplicity, and portability, and the liquid chromatography tandem mass spectrometry system could be used for validation in laboratory conditions with the advantage of lower limit of detection, stability, and precision. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Xu, Jucai; Sun-Waterhouse, Dongxiao; Qiu, Chaoying; Zhao, Mouming; Sun, Baoguo; Lin, Lianzhu; Su, Guowan
2017-10-27
The need to improve the peak capacity of liquid chromatography motivates the development of two-dimensional analysis systems. This paper presented a fully automated stop-flow two-dimensional liquid chromatography system with size exclusion chromatography followed by reversed phase liquid chromatography (SEC×RPLC) to efficiently separate peptides. The effects of different stop-flow operational parameters (stop-flow time, peak parking position, number of stop-flow periods and column temperature) on band broadening in the first dimension (1 st D) SEC column were quantitatively evaluated by using commercial small proteins and peptides. Results showed that the effects of peak parking position and the number of stop-flow periods on band broadening were relatively small. Unlike stop-flow analysis of large molecules with a long running time, additional band broadening was evidently observed for small molecule analytes due to the relatively high effective diffusion coefficient (D eff ). Therefore, shorter analysis time and lower 1 st D column temperature were suggested for analyzing small molecules. The stop-flow two-dimensional liquid chromatography (2D-LC) system was further tested on peanut peptides and an evidently improved resolution was observed for both stop-flow heart-cutting and comprehensive 2D-LC analysis (in spite of additional band broadening in SEC). The stop-flow SEC×RPLC, especially heart-cutting analysis with shorter analysis time and higher 1 st D resolution for selected fractions, offers a promising approach for efficient analysis of complex samples. Copyright © 2017 Elsevier B.V. All rights reserved.
Raust, Jacques-Antoine; Bruell, Adele; Sinha, Pritish; Hiller, Wolf; Pasch, Harald
2010-09-01
A comprehensive two-dimensional liquid chromatography system was developed to precisely describe the molecular heterogeneity of fatty alcohol ethoxylates. The end-group functionality was analyzed by gradient HPLC while ethylene oxide oligomer distributions were characterized by liquid adsorption chromatography. A baseline separation of all functionality fractions irrespective of the ethylene oxide oligomer chain length was achieved on nonpolar X-Terra(®) C(18) with a methanol-water gradient, whereas an isocratic flow of isopropanol-water on a polar Chromolith(®) Si column gave a separation according to the oligomer chain length without interference of the end-group distribution. The combination of these two methods to conduct online two-dimensional liquid chromatography experiments resulted in a comprehensive two-dimensional picture on the molecular heterogeneity of the sample.
Electrochemical Detectors in HPLC and Ion Chromatography.
Horvai, George; Pungor, ErnÕ
1989-01-01
Back in 1952, the renowned Polish electrochemist Wiktor Kemula introduced chromato-polarography, 1 i.e., polaro-graphic detection for liquid chromatography. This technique continued to develop slowly until the early 1970s (for a review see Reference 2) when modem high-performance liquid chromatography (HPLC) emerged. This new, highly efficient chromatographc method could only be. used with detectors ensuring low dispersion. It was not easy to modify the dropping mercury electrode cells to satisfy this requirement. However, at the same time, electroanalytical chemists, who already had much experience in using carbon-based electrodes for oxidative detection in flow analysis, put forward the idea of oxidative amperometric detection in liquid chromatography. 3,4 In this technique, solid or quasi-solid (paste) electrodes were used and this made possible the construction of miniaturized cells with just a few microliter volume.
Baranowska, Irena; Adolf, Weronika; Magiera, Sylwia
2015-11-01
A sensitive, stereoselective assay using solid phase extraction and high-performance liquid chromatography (HPLC) with fluorescence detection (FLD) was developed and validated for the analysis of enantiomers of metoprolol and its metabolites (α-hydroxymetoprolol, O-desmethylmetoprolol). Chiral separation was achieved using a CHIRALCEL OD-RH column, packed with cellulose tris-(3,5-dimethylphenyl-carbamate) stationary phase, employing a mobile phase composed by a mixture of 0.2% diethylamine in water and acetonitrile in gradient elution mode. Linear calibration curves were obtained over the range of 0.025-2.0μg/mL (R(2)>0.994) in urine for both enantiomers of metoprolol and its metabolites with quantitation limit of 0.025μg/mL. Intra and inter-day precision and accuracy were below 15% for both metoprolol and metabolites enantiomers. The recovery of enantiomer of metoprolol and its metabolite was greater than 68.0%, utilizing a SPE procedure. The method was tested with urine quality control samples and human urine fractions after administration of 50mg rac-metoprolol. Copyright © 2015 Elsevier B.V. All rights reserved.
Gorman, Gregory; Sokom, Simara; Coward, Lori; Arnold, John J
2017-01-01
Topical gels compounded by pharmacists are important clinical tools for the management of pain. Nevertheless, there is often a dearth of information about the chemical stability of drugs included in these topical formulations, complicating the assignment of beyond-use dating. The purpose of this study was to develop a high-performance liquid chromatography photodiode array-based stability-indicating assay that could simultaneously resolve six drugs (amitriptyline, baclofen, clonidine, gabapentin, ketoprofen, lidocaine) commonly included in topical gels for pain management and their potential degradation products. Furthermore, this method was applied to the determination of beyond-use dating of combinations of these drugs prepared in commonly utilized bases (Lipobase, Lipoderm, Pluronic organogel). Gabapentin was determined to be the least stable component in all formulations tested. Measured stability ranged between 7 to 49 days depending on the base and other active drugs present in the formulation. In the absence of gabapentin, baclofen was the next least stable component, lasting for 120 days, regardless of the type of formulating base used. Copyright© by International Journal of Pharmaceutical Compounding, Inc.
Kendrick, B S; Kerwin, B A; Chang, B S; Philo, J S
2001-12-15
Characterizing the solution structure of protein-polymer conjugates and protein-ligand interactions is important in fields such as biotechnology and biochemistry. Size-exclusion high-performance liquid chromatography with online classical light scattering (LS), refractive index (RI), and UV detection offers a powerful tool in such characterization. Novel methods are presented utilizing LS, RI, and UV signals to rapidly determine the degree of conjugation and the molecular mass of the protein conjugate. Baseline resolution of the chromatographic peaks is not required; peaks need only be sufficiently separated to represent relatively pure fractions. An improved technique for determining the polypeptide-only mass of protein conjugates is also described. These techniques are applied to determining the degree of erythropoietin glycosylation, the degree of polyethylene glycol conjugation to RNase A and brain-derived neurotrophic factor, and the solution association states of these molecules. Calibration methods for the RI, UV, and LS detectors will also be addressed, as well as online methods to determine protein extinction coefficients and dn/dc values both unconjugated and conjugated protein molecules. (c)2001 Elsevier Science.
Inagaki, Shinsuke; Noda, Takumi; Min, Jun Zhe; Toyo'oka, Toshimasa
2007-12-28
An exhaustive analysis of metabolites in hair samples has been performed for the first time using ultra performance liquid chromatography with electrospray ionization time-of-flight mass spectrometry (UPLC-ESI-TOF-MS). The hair samples were collected from spontaneously hypertensive model rats (SHR/Izm), stroke-prone SHR (SHRSP/Izm) and Wistar Kyoto (WKY/Izm) rats, and were analyzed by UPLC-ESI-TOF-MS; a multivariate statistical analysis method, such as the principal component analysis (PCA), was then used for screening the biomarkers. From the samples derived from the group of SHRSP/Izm at weeks 10, 18, 26 and 34, we successfully detected a potential biomarker of stroke, which existed at much higher concentrations as compared with that in the other groups. However, a significant difference could not be found at weeks less than 7 before the rats were subjected to stroke and hypertension. In addition, the present method was applicable to screening not only the disease markers, but also the markers related to aging. The method utilizing hair samples is expected to be quite useful for screening biomarkers of many other diseases, and not limited to stroke and hypertension.
Niemi, Lydia M; Stencel, Katherine A; Murphy, Madigan J; Schultz, Melissa M
2013-08-06
Antidepressants are one of the most widely dispensed classes of pharmaceuticals in the United States. As wastewater treatment plants are a primary source of pharmaceuticals in the environment, the use of biosolids as fertilizer is a potential route for antidepressants to enter the terrestrial environment. A microsolvent extraction method, utilizing green chemistry, was developed for extraction of the target antidepressants and degradation products from biosolids, or more specifically lagoon biosolids. Liquid chromatography/tandem mass spectrometry was used for quantitative determination of antidepressants in the lagoon biosolid extracts. Recoveries from matrix spiking experiments for the individual antidepressants had an average of 96%. The limits of detection for antidepressant pharmaceuticals and degradates ranged from 0.36 to 8.0 ng/kg wet weight. The method was applied to biosolids destined for land application. A suite of antidepressants was consistently detected in the lagoon biosolid samples, and thus antidepressants are being introduced to terrestrial environments through the land application of these biosolids. Sertraline and norsertraline were the most abundant antidepressant and degradation product detected in the biosolid samples. Detected, individual antidepressant concentrations ranged from 8.5 ng/kg (norfluoxetine) to 420 ng/kg wet weight (norsertraline).
Xia, Hongrui; Sun, Longru; Lou, Hongxiang; Rahman, M Mukhlesur
2014-05-15
Salvianolic acid A (Sal A), an important constituent of Radix Salviae Miltiorrhizae (RSM), is effective for the treatment of myocardial infarction (MI) and coronary heart disease due to its potential in the improvement of acute myocardial ischemia. However, its content is very low in RSM. So it is obvious to find a rich source of Sal A or to improve its content by conversion of other related components into Sal A modifying reaction conditions. In this research we focused on the conversion of Sal B into Sal A in aqueous solutions of RSM by using different reaction conditions including pH, temperature, pressure and humidity. During the reactions, the contents of Sal A, Sal B and danshensu in the RSM were analyzed by high-performance liquid chromatography (HPLC) and liquid chromatography-mass spectrometry (LCMS). The results indicated that the conversion of Sal B into Sal A in RSM tissues under the conditions of a high temperature, high pressure and high humidity was efficient and thereby, was readily utilized to prepare rich Sal A materials in practice. Copyright © 2014 Elsevier GmbH. All rights reserved.
Weng, Zebin; Zeng, Fei; Zhu, Zhenhua; Qian, Dawei; Guo, Sheng; Wang, Hanqing; Duan, Jin-Ao
2018-07-15
The root of Sophora flavescens Ait. has long been used as a crude drug in China and other Asian countries for thousands of years. The quinolizidine alkaloids and flavonoids are considered as the main bioactive components in this plant. To determine the distribution and content of the flavonoids in different organs of this plant, a rapid, sensitive and reproducible method was established using ultra-high-performance liquid chromatography coupled with a triple quadrupole electrospray tandem mass spectrometry. A total of sixteen flavonoids including five different types (isoflavones, pterocarpans, flavones, flavonols and prenylflavonoids) were simultaneously determined in 10 min. The established method was fully validated in terms of linearity, sensitivity, precision, repeatability as well as recovery and successfully applied in the methanolic extracts of S. flavescens parts (root, stem, leaf, pod and seed). The analysis results indicated that the distribution and contents of different type of flavonoids showed remarkable differences among the five organs of S. flavescens. This study might be useful for the rational utilization of S. flavescens resource. Copyright © 2018 Elsevier B.V. All rights reserved.
Zeeb, D J; Nelson, B C; Albert, K; Dalluge, J J
2000-10-15
A method has been developed for the direct microscale determination of 12 catechins in green and black tea infusions. The method is based on liquid chromatography/atmospheric pressure chemical ionization-mass spectrometry (LC/APCI-MS). Standard catechin mixtures and tea infusions were analyzed by LC/APCI-MS with detection of protonated molecular ions and characteristic fragment ions for each compound. The identities of eight major catechins and caffeine in tea were established based on LC retention times and simultaneously recorded mass spectra. In addition, monitoring of the catechin-specific retro Diels-Alder fragment ion at m/z 139 throughout the chromatogram provided a unique fingerprint for catechin content in the samples that led to the identification of four minor chemically modified catechin derivatives in the infusions. This report is the first to describe the comprehensive determination of all 12 reported catechins in a single analysis. The utility of LC/APCI-MS for providing routine separation and identification of catechins at femtomole to low-picomole levels without extraction or sample pretreatment, and its potential as a standard analytical tool for the determination of polyphenols in natural products and biological fluids, are discussed.
Kubo, Takuya; Hosoya, Ken; Watabe, Yoshiyuki; Ikegami, Tohru; Tanaka, Nobuo; Sano, Tomoharu; Kaya, Kunimitsu
2004-03-12
A polymer-based adsorption medium having molecular recognition ability for homologues of chlorinated bisphenol A produced in environment was prepared using a fragment imprinting technique. 2,6-Dimethyl phenol was utilized as a pseudo-template molecule and the adsorption media prepared was evaluated by high performance liquid chromatography (HPLC) and solid-phase extraction (SPE). As results, the adsorption medium showed preferable chromatographic retention and specific adsorption ability for the chlorinated bisphenol As having chlorine substituents at 3,5-positions through fragment imprinting effect.
What is the study?
An invited review article. Measurement of oxidative stress parameters using liquid chromatography-tandem mass spectroscopy (LC-MS/MS)
Why was it done?
Although oxidative stress is frequently cited as a cause of various adverse biological eff...
A high performance liquid chromatography (HPLC) method was developed to quantitatively determine phenolic compounds and their isomers in aqueous samples. The HPLC method can analyze a mixture of 15 contaminants in the same analytical run with an analysis time of 25 minutes. The...
A simple method for the quantitative determination of elemental sulfur on oxidized sulfide minerals is described. Extraction of elemental sulfur in perchloroethylene and subsequent analysis with high-performance liquid chromatography were used to ascertain the total elemental ...
ERIC Educational Resources Information Center
Ondrus, Martin G.; And Others
1983-01-01
Advocates use of Waters Associates Radial Compression Separation System for high performance liquid chromatography. Discusses instrumentation and reagents, outlining procedure for analyzing various foods and discussing typical student data. Points out potential problems due to impurities and pump seal life. Suggests use of ribose as internal…
The concurrent determination of pesticidal and non-pesticidal organotin compounds in several water matrices, using a simultaneous in situ ethylation and liquid-liquid extraction followed by splitless injection mode capillary gas chromatography with pulsed flame photometric detect...
This research was conducted in cooperation with EPA Region 4 in Athens, GA to develop a method to analyze selected pyrethroid pesticides using Reverse Phase-High Pressure Liquid Chromatography (HPLC). This HPLC method will aid researchers in separating and identifying these pyre...
This document is a standardized, single laboratory validated liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the detection of cyanotoxins—microsystins and nodularin (combined intracellular and extracellular)—in ambient freshwaters.
A method using reversed phase high performance liquid chromatography/electrospray ionization-mass spectrometric (RP-LC/ESI-MS) method has been developed to confirm the identity of dansylated derivatives of cysteine and glutathione, and their respective dimers. Cysteine, GSH, CSSC...
USDA-ARS?s Scientific Manuscript database
This work describes the development and validation of a method for the simultaneous determination of 13 estrogens and progestogens in honey by high performance liquid chromatography-tandem mass spectrometry. The target compounds were preconcentrated by solid phase extraction. Pretreatment variables ...
High-Performance Liquid Chromatography in the Undergraduate Chemical Engineering Laboratory
ERIC Educational Resources Information Center
Frey, Douglas D.; Guo, Hui; Karnik, Nikhila
2013-01-01
This article describes the assembly of a simple, low-cost, high-performance liquid chromatography (HPLC) system and its use in the undergraduate chemical engineering laboratory course to perform simple experiments. By interpreting the results from these experiments students are able to gain significant experience in the general method of…
Method MS014 describes procedures for solvent extraction of aldicarb, bromadiolone, carbofuran, oxamyl and methomyl from water samples, followed by analysis using liquid chromatography tandem mass spectrometry (LC-MS-MS).
Quantification of Tea Flavonoids by High Performance Liquid Chromatography
ERIC Educational Resources Information Center
Freeman, Jessica D.; Niemeyer, Emily D.
2008-01-01
We have developed a laboratory experiment that uses high performance liquid chromatography (HPLC) to quantify flavonoid levels in a variety of commercial teas. Specifically, this experiment analyzes a group of flavonoids known as catechins, plant-derived polyphenolic compounds commonly found in many foods and beverages, including green and black…
ERIC Educational Resources Information Center
Haddad, Paul; And Others
1983-01-01
Background information, procedures, and results are provided for an experiment demonstrating techniques of solvent selection, gradient elution, pH control, and ion-pairing in the analysis of an analgesic mixture using reversed-phase liquid chromatography on an octadecylsilane column. Although developed using sophisticated/expensive equipment, less…
ERIC Educational Resources Information Center
Bidlingmeyer, Brian A.; Warren, F. Vincent, Jr.
1984-01-01
Background information, materials needed, laboratory procedures, and typical results are provided for five high performance liquid chromatography experiments (three isocratic and two step gradient separations). Suggestions for further experimentation are also provided, including quantitative determinations and separation of charged solutes. (JN)
A high performance liquid chromatography (HPLC) method was developed to quantitatively determine phenolic compounds and their isomers in aqueous samples. The HPLC method can analyze a mixture of 15 contaminants in the same analytical run with an analysis time of 25 minutes. The...
USDA-ARS?s Scientific Manuscript database
High performance liquid chromatography (UPLC) and flow injection electrospray ionization with ion trap mass spectrometry (FIMS) fingerprints combined with the principal component analysis (PCA) were examined for their potential in differentiating commercial organic and conventional sage samples. The...
ERIC Educational Resources Information Center
Benson, G. A.
1982-01-01
An experiment using gas-liquid chromatography is discussed, introducing the student to concept of dead volume and its measurement, idea and use of an internal reference compound, and to linear relationship existing between measurements of a separation on two different stationary phases. (Author/SK)
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-15
... using capillary gas liquid chromatography (GLC) with flame ionization detector (FID). Contact: Andrew...) purification. Detection and quantitation are conducted by gas chromatograph equipped with nitrogen phosphorus... pressure liquid chromatography/triple stage quadrupole mass spectrometry (LC/MS/MS) using the stable...
Caes, Benjamin R.; Van Oosbree, Thomas R.; Lu, Fachuang; Ralph, John; Maravelias, Christos T.
2015-01-01
Simulated moving bed chromatography, a continuous separation method, enables the nearly quantitative recovery of sugar products and ionic liquid solvent from chemical hydrolysates of biomass. The ensuing sugars support microbial growth, and the residual lignin from the process is intact. PMID:23939991
Saleh, Aljona; Stephanson, Niclas Nikolai; Granelli, Ingrid; Villén, Tomas; Beck, Olof
2012-11-15
In this study a rapid liquid chromatography-time-of-flight mass spectrometry method was developed, validated and applied in order to evaluate the potential of this technique for routine urine drug testing. Approximately 800 authentic patient samples were analyzed for amphetamines (amphetamine and methamphetamine), opiates (morphine, morphine-3-glucuronide, morphine-6-glucuronide, codeine and codeine-6-glucuronide) and buprenorphines (buprenorphine and buprenorphine-glucuronide) using immunochemical screening assays and mass spectrometry confirmation methods for comparison. The chromatographic application utilized a rapid gradient with high flow and a reversed phase column with 1.8 μm particles. Total analysis time was 4 min. The mass spectrometer operated with an electrospray interface in positive mode with a resolution power of >10,000 at m/z 956. The applied reporting limits were 100 ng/mL for amphetamines and opiates, and 5 ng/mL for buprenorphines, with lower limits of quantification were 2.8-41 ng/mL. Calibration curves showed a linear response with coefficients of correlation of 0.97-0.99. The intra- and interday imprecision in quantification at the reporting limits were <10% for all analytes but for buprenorphines <20%. Method validation data met performance criteria for a qualitative and quantitative method. The liquid chromatography-time-of-flight mass spectrometry method was found to be more selective than the immunochemical method by producing lower rates of false positives (0% for amphetamines and opiates; 3.2% for buprenorphines) and negatives (1.8% for amphetamines; 0.6% for opiates; 0% for buprenorphines). The overall agreement between the two screening methods was between 94.2 and 97.4%. Comparison of data with the confirmation (LC-MS) results for all individual 9 analytes showed that most deviating results were produced in samples with low levels of analytes. False negatives were mainly related to failure of detected peak to meet mass accuracy criteria (±20 mDa). False positives was related to presence of interfering peaks meeting mass accuracy and retention time criteria and occurred mainly at low levels. It is concluded that liquid chromatography-time-of-flight mass spectrometry has potential both as a complement and as replacement of immunochemical screening assays. Copyright © 2012 Elsevier B.V. All rights reserved.
High Performance Thin Layer Chromatography.
ERIC Educational Resources Information Center
Costanzo, Samuel J.
1984-01-01
Clarifies where in the scheme of modern chromatography high performance thin layer chromatography (TLC) fits and why in some situations it is a viable alternative to gas and high performance liquid chromatography. New TLC plates, sample applications, plate development, and instrumental techniques are considered. (JN)
Doshi, Gaurav Mahesh; Une, Hemant Devidas
2016-01-01
Objective: In Indian Ayurvedic system, Benincasa hispida (BH) and Carissa congesta (CC) are well-known plants used for major and minor ailments. BH has been regarded as Kushmanda, whereas CC has been used in immune-related disorders of the human system. Quercetin and rutin identified from the vast plethora of plant extracts have proved to possess ethnopharmacological relevance. Materials and Methods: In present studies, we have determined quercetin and rutin in terms of percentage in BH seeds and CC roots by high-performance thin layer chromatography (HPTLC) and high-performance liquid chromatography (HPLC). After extraction and phytochemical screening, the extracts were subjected to quantification for the presence of quercetin and rutin by HPTLC and HPLC. Results: HPTLC showed quercetin as 44.60, 27.13% and rutin as 32.00, 36.31% w/w, whereas HPLC revealed quercetin as 34.00, 35.00% and rutin as 21.99, 45.03% w/v in BH and CC extracts, respectively. Conclusion: The BH and CC extracts have elucidated peaks that were corresponding with standard peaks on undertaking chromatographic studies. SUMMARY Quercetin and rutin are isolated from BH seeds and CC roots by High Performance. Thin Layer Chromatography and High Performance Liquid Chromatography. HPTLC revealed presence of quercetin as 44.60, 27.13 % and rutin as 32.00, 36.31 % w/w. HPLC revealed presence of quercetin as 34.00, 35.00 % and rutin as 21.99, 45.03 % w/v. Abbreviation Used: HPTLC: High Performance Thin Layer Chromatography; HPLC: High Pressure Liquid Chromatography, UV: Ultraviolet, CC: Carissa congesta, BH: Benincasa hispida PMID:26941534
DOE Office of Scientific and Technical Information (OSTI.GOV)
He, Hongkun; Zhong, Mingjiang; Adzima, Brian
2013-03-20
Poly(ionic liquid)s (PILs) are an important class of technologically relevant materials. However, characterization of well-defined polyionic materials remains a challenge. Herein, we have developed a simple and versatile gel permeation chromatography (GPC) methodology for molecular weight (MW) characterization of PILs with a variety of anions. PILs with narrow MW distributions were synthesized via atom transfer radical polymerization, and the MWs obtained from GPC were further confirmed via nuclear magnetic resonance end group analysis.
Kurmi, Moolchand; Sahu, Archana; Singh, Saranjit
2017-02-05
In the present study, degradation behaviour of abacavir sulfate was evaluated in solution and solid stress conditions. Solution state studies resulted in formation of eleven degradation products; of which two were also formed on solid stress. The same were separated by high performance liquid chromatography. They were characterized using liquid chromatography-high resolution mass spectrometry, liquid chromatography-multistage mass spectrometry and hydrogen/deuterium exchange mass spectrometry data. Additionally, seven degradation products were isolated and subjected to 1D and 2D nuclear magnetic resonance studies for their structural confirmation. Copyright © 2016 Elsevier B.V. All rights reserved.
21 CFR 177.1990 - Vinylidene chloride/methyl acrylate copolymers.
Code of Federal Regulations, 2013 CFR
2013-04-01
... in Saran MA/VDC Resins and Pellets by Headspace Gas Chromatography,” dated March 3, 1986, which are... gel permeation chromatography using tetrahydrofuran as the solvent. The gel permeation chromatograph... Distribution of Polystyrene by Liquid Exclusion Chromatography (Gel Permeation Chromatography-GPC),” which is...
21 CFR 177.1990 - Vinylidene chloride/methyl acrylate copolymers.
Code of Federal Regulations, 2012 CFR
2012-04-01
... in Saran MA/VDC Resins and Pellets by Headspace Gas Chromatography,” dated March 3, 1986, which are... gel permeation chromatography using tetrahydrofuran as the solvent. The gel permeation chromatograph... Distribution of Polystyrene by Liquid Exclusion Chromatography (Gel Permeation Chromatography-GPC),” which is...
21 CFR 177.1990 - Vinylidene chloride/methyl acrylate copolymers.
Code of Federal Regulations, 2010 CFR
2010-04-01
... in Saran MA/VDC Resins and Pellets by Headspace Gas Chromatography,” dated March 3, 1986, which are... gel permeation chromatography using tetrahydrofuran as the solvent. The gel permeation chromatograph... Distribution of Polystyrene by Liquid Exclusion Chromatography (Gel Permeation Chromatography-GPC),” which is...
21 CFR 177.1990 - Vinylidene chloride/methyl acrylate copolymers.
Code of Federal Regulations, 2011 CFR
2011-04-01
... in Saran MA/VDC Resins and Pellets by Headspace Gas Chromatography,” dated March 3, 1986, which are... gel permeation chromatography using tetrahydrofuran as the solvent. The gel permeation chromatograph... Distribution of Polystyrene by Liquid Exclusion Chromatography (Gel Permeation Chromatography-GPC),” which is...
Recent development of ionic liquid stationary phases for liquid chromatography.
Shi, Xianzhe; Qiao, Lizhen; Xu, Guowang
2015-11-13
Based on their particular physicochemical characteristics, ionic liquids have been widely applied in many fields of analytical chemistry. Many types of ionic liquids were immobilized on a support like silica or monolith as stationary phases for liquid chromatography. Moreover, different approaches were developed to bond covalently ionic liquids onto the supporting materials. The obtained ionic liquid stationary phases show multi-mode mechanism including hydrophobic, hydrophilic, hydrogen bond, anion exchange, π-π, and dipole-dipole interactions. Therefore, they could be used in different chromatographic modes including ion-exchange, RPLC, NPLC and HILIC to separate various classes of compounds. This review mainly summarizes the immobilized patterns and types of ionic liquid stationary phases, their retention mechanisms and applications in the recent five years. Copyright © 2015 Elsevier B.V. All rights reserved.
Julka, Samir; Cortes, Hernan; Harfmann, Robert; Bell, Bruce; Schweizer-Theobaldt, Andreas; Pursch, Matthias; Mondello, Luigi; Maynard, Shawn; West, David
2009-06-01
A comprehensive multidimensional liquid chromatography system coupled to Electrospray Ionization-Mass Spectrometry (LCxLC-ESI-MS) was developed for detailed characterization and quantitation of solid epoxy resin components. The two orthogonal modes of separation selected were size exclusion chromatography (SEC) in the first dimension and liquid chromatography at critical conditions (LCCC) in the second dimension. Different components present in the solid epoxy resins were separated and quantitated for the first time based on the functional groups and molecular weight heterogeneity. Coupling LCxLC separations with mass spectrometry enabled the identification of components resolved in the two-dimensional space. Several different functional group families of compounds were separated and identified, including epoxy-epoxy and epoxy-alpha-glycol functional oligomers, and their individual molecular weight ranges were determined. Repeatability obtained ranged from 0.5% for the main product to 21% for oligomers at the 0.4% concentration level.
An, Meichen; Liu, Ning
2010-02-01
A high performance liquid chromatography-matrix-assisted laser desorption/ionization time of flight/time of flight mass spectrometry (HPLC-MALDI-TOF/TOF MS) method was developed for the separation and identification of bovine lactoferricin (LfcinB). Bovine lactoferrin was hydrolyzed by pepsin and then separated by ion exchange chromatography and reversed-phase liquid chromatography (RP-LC). The antibacterial activities of the fractions from RP-LC separation were determined and the protein concentration of the fraction with the highest activity was measured, whose sequence was indentified by MALDI-TOF/TOF MS. The relative molecular mass of LfcinB was 3 124.89 and the protein concentration was 18.20 microg/mL. The method of producing LfcinB proposed in this study has fast speed, high accuracy and high resolution.
Yao, Shun; Liu, Renming; Huang, Xuefeng; Kong, Lingyi
2007-01-19
Preparative high-speed counter-current chromatography (HSCCC), as a continuous liquid-liquid partition chromatography with no solid support matrix, combined with evaporative light scattering detection (ELSD) was employed for systematic separation and purification of non-chromophoric chemical components from Chinese medicinal herb Adenophora tetraphlla (Thunb.), Fisch. Nine compounds, including alpha-spinasterol, beta-sitosterol, nonacosan-10-ol, 24-methylene cycloartanol, lupenone, 3-O-palmitoyl-beta-sitosterol, 3-O-beta-d-glucose-beta-sitosterol, eicosanoic acid and an unknown compound, were obtained. The compounds were all above 95% determined by high-performance liquid chromatography (HPLC)-ELSD, and their structures were identified by (1)H NMR and chemical ionization mass spectroscopy (CI-MS). The results demonstrate that HSCCC coupled with ELSD is a feasible and efficient technique for systematic isolation of non-chromophoric components from traditional medicinal herbs.
Yang, Xiao; Diao, Chun-Peng; Sun, Ai-Ling; Liu, Ren-Min
2014-10-01
A method for the rapid pretreatment and determination of bisphenol A in water samples based on vortex-assisted liquid-liquid microextraction followed by high-performance liquid chromatography with fluorescence detection was proposed in this paper. A simple apparatus consisting of a test tube and a cut-glass dropper was designed and applied to collect the floating extraction drop in liquid-liquid microextraction when low-density organic solvent was used as the extraction solvent. Solidification and melting steps that were tedious but necessary once the low-density organic solvent used as extraction solvent could be avoided by using this apparatus. Bisphenol A was selected as model pollutant and vortex-assisted liquid-liquid microextraction was employed to investigate the usefulness of the apparatus. High-performance liquid chromatography with fluorescence detection was selected as the analytical tool for the detection of bisphenol A. The linear dynamic range was from 0.10 to 100 μg/L for bisphenol A, with good squared regression coefficient (r(2) = 0.9990). The relative standard deviation (n = 7) was 4.7% and the limit of detection was 0.02 μg/L. The proposed method had been applied to the determination of bisphenol A in natural water samples and was shown to be economical, fast, and convenient. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Liquid Chromatography-Mass Spectrometry-based Quantitative Proteomics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xie, Fang; Liu, Tao; Qian, Weijun
2011-07-22
Liquid chromatography-mass spectrometry (LC-MS)-based quantitative proteomics has become increasingly applied for a broad range of biological applications due to growing capabilities for broad proteome coverage and good accuracy in quantification. Herein, we review the current LC-MS-based quantification methods with respect to their advantages and limitations, and highlight their potential applications.
USDA-ARS?s Scientific Manuscript database
Analysis of 9 macrolides is presented, including tulathromycin A (Draxxin), in beef, poultry and pork muscle with a simple multi-residue extraction and analysis method using high performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry. The extraction method inv...
USDA-ARS?s Scientific Manuscript database
Panax quinquefolius L (P. quinquefolius L) samples grown in the United States and China were analyzed with high performance liquid chromatography-mass spectrometry (HPLC—MS). Prior to classification, the two-way datasets were subjected to pretreatment including baseline correction and retention tim...
USDA-ARS?s Scientific Manuscript database
Panax quinquefolius L (P. quinquefolius L) samples grown in the United States and China were analyzed with high performance liquid chromatography-mass spectrometry (HPLC—MS). Prior to classification, the two-way datasets were subjected to pretreatment including baseline correction and retention ti...
ERIC Educational Resources Information Center
Lee, Iris; Boyce, Mary C.
2011-01-01
A student activity that focuses on the isolation of glucoraphanin from broccoli using preparative high-performance liquid chromatography (HPLC) is presented here. Glucoraphanin is a glucosinolate, whose byproducts are known to possess anticancer properties. It is present naturally at high levels in broccoli and other "Brassica" vegetables. This…
Polycyclic aromatic hydrocarbons (PAHs) comprise a class of potentially hazardous compounds of concern to the U.S.EPA. The application of particle-beam (PB) liquid chromatography-mass spectrometry (LC-MS) to the measurement of high-molecular-weight PAHs was investigated. Instrume...
An Advanced, Interactive, High-Performance Liquid Chromatography Simulator and Instructor Resources
ERIC Educational Resources Information Center
Boswell, Paul G.; Stoll, Dwight R.; Carr, Peter W.; Nagel, Megan L.; Vitha, Mark F.; Mabbott, Gary A.
2013-01-01
High-performance liquid chromatography (HPLC) simulation software has long been recognized as an effective educational tool, yet many of the existing HPLC simulators are either too expensive, outdated, or lack many important features necessary to make them widely useful for educational purposes. Here, a free, open-source HPLC simulator is…
Matrix effects break the LC behavior rule for analytes in LC-MS/MS analysis of biological samples
USDA-ARS?s Scientific Manuscript database
High-performance liquid chromatography (HPLC) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) are generally accepted as the preferred techniques for detecting and quantitating analytes of interest in biological matrices on the basis of the rule that one chemical compound yields one LC-...
ERIC Educational Resources Information Center
Kagel, R. A.; Farwell, S. O.
1983-01-01
Background information, procedures, and results, are provided for an undergraduate experiment in which analgesic tablets are analyzed using liquid chromatography. The experiment, an improved, modified version of the Waters Associates Inc. experiment, is simple to prepare, requiring little glassware and minimal sample manipulation by students. (JN)
NASA Astrophysics Data System (ADS)
Deineka, V. I.; Lapshova, M. S.; Deineka, L. A.
2014-06-01
It is shown by means of reversed phase high performance liquid chromatography (RP HPLC) with mobile phases containing additions of β-cyclodextrin that 5-glucosides of cyanidin and pelargonidin form stronger inclusion complexes than 3-glucosides; this is explained by the steric interference of the glucoside radical.
The concurrent determination of pesticidal and non-pesticidal organotin compounds in several water matrices, using a simultaneous in situ ethylation and liquid-liquid extraction followed by splitless injection mode capillary gas chromatography with pulsed flame photometric detect...
Yang, Lili; Jin, Fen; Zhang, Peng; Zhang, Yanxin; Wang, Jian; Shao, Hua; Jin, Maojun; Wang, Shanshan; Zheng, Lufei; Wang, Jing
2015-09-30
A simple analytical method was developed for the simultaneous analysis of 18 perfluorinated compounds (PFCs) in edible oil. The target compounds were extracted by acetonitrile, purified by gel permeation chromatography (GPC) and dispersive solid-phase extraction (DSPE) using graphitized carbon black (GCB) and octadecyl (C18), and analyzed by liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ES-MS/MS) in negative ion mode. Recovery studies were performed at three fortification levels. The average recoveries of all target PFCs ranged from 60 to 129%, with an acceptable relative standard deviation (RSD) (1-20%, n = 3). The method detection limits (MDLs) ranged from 0.004 to 0.4 μg/kg, which was significantly improved compared with the existing liquid-liquid extraction and cleanup method. The method was successfully applied for the analysis of all target PFCs in edible oil samples collected from markets in Beijing, China, and the results revealed that C6-C10 perfluorocarboxylic acid (PFCAs) and C7 perfluorosulfonic acid PFSAs were the major PFCs detected in oil samples.
Jia, Youmei; Cai, Jianfeng; Xin, Huaxia; Feng, Jiatao; Fu, Yanhui; Fu, Qing; Jin, Yu
2017-06-08
A preparative two dimensional hydrophilic interaction liquid chromatography/reversed-phase liquid chromatography (Pre-2D-HILIC/RPLC) method was established to separate and purify the components in Trachelospermum jasminoides . The pigments and strongly polar components were removed from the crude extract after the active carbon decolorization and solid phase extraction processes. A Click XIon column (250 mm×20 mm, 10 μm) was selected as stationary phase and water-acetonitrile as mobile phases in the first dimensional HILIC. Finally, 15 fractions were collected under UV-triggered mode. In the second dimensional RPLC, a C18 column (250 mm×20 mm, 5 μm) was selected and water-acetonitrile was used as mobile phases. As a result, 14 compounds with high purity were obtained, which were further identified by mass spectrometry (MS) and nuclear magnetic resonance (NMR). Finally, 11 lignan compounds and three flavonoid compounds were obtained. The method has a good orthogonality, and can improve the resolution and the peak capacity. It is significant for the separation of complex components from Trachelospermum jasminoides .
Zhang, Chunhui; Ning, Ke; Zhang, Wenwen; Guo, Yuanjie; Chen, Jun; Liang, Chen
2013-04-01
Increased attention is currently being directed towards the potential negative effects of antibiotics and other PPCPs discharged into the aquatic environment via municipal WWTP secondary effluents. A number of analytical methods, such as high performance liquid chromatography technologies, including a high performance liquid chromatography-fluorescence method (HPLC-FLD), high performance liquid chromatography-UV detection method (HPLC-UV) and high performance liquid chromatography-mass spectrometry method (HPLC-MS), have been suggested as determination technologies for antibiotic residues in water. In this study, we implement a HPLC-MS/MS combined method to detect and analyze antibiotics in WWTP secondary effluent and apply a horizontal subsurface flow constructed wetland (CW) as an advanced wastewater treatment for removing antibiotics in the WWTP secondary effluent. The results show that there were 2 macrolides, 2 quinolones and 5 sulfas in WWTP secondary effluent among all the 22 antibiotics considered. After the CW advanced treatment, the concentration removal efficiencies and removal loads of 9 antibiotics were 53-100% and 0.004-0.7307 μg m(-2) per day, respectively.
Liu, Lei; Cao, Na; Ma, Xingling; Xiong, Kaihe; Sun, Lili; Zou, Qiaogen
2016-04-01
High-performance liquid chromatography analysis of vonoprazan fumarate, a novel proton pump inhibitor drug revealed six impurities. These were identified by liquid chromatography with mass spectrometry. Further, the structures of the impurities were confirmed by synthesis followed by characterization by mass spectrometry, NMR spectroscopy, and infrared spectroscopy. On the basis of these data and knowledge of the synthetic scheme of vonoprazan fumarate, the previously unknown impurity was identified as 1-[5-(2-fluorophenyl)-1-(pyridin-3-ylsulfonyl)-1H-pyrrol-3-yl]-N-methyldimethylamine, which is a new compound. The possible mechanisms by which these impurities were formed were also discussed. A high-performance liquid chromatography method was optimized in order to separate, selectively detect, and quantify all process-related impurities of vonoprazan fumarate. The presented method has been validated in terms of linearity, limits of detection, and quantification, and response factors and, therefore, is highly suitable for routine analysis of vonoprazan fumarate related substances as well as stability studies. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Major and Modified Nucleosides, RNA, and DNA
NASA Astrophysics Data System (ADS)
Gehrke, Charles W.; Kuo, Kenneth C.
Most analytical chemists are well aware of the rapid rate of development of high-performance liquid chromatography (HPLC) over the past 5 years. A number of articles have been published in Analytical Chemistry on different topics in HPLC and many papers appear in the chromatographic journals. Some books also have been published covering this subject. HPLC has proved to be a very effective, broadly applicable chromatographic method for the separation and analysis of complex molecules in fields as diverse as biochemistry and environmental, pharmaceutical, medical, and polymer chemistry. HPLC is now having a major impact on the clinical and research aspects of medical biochemistry. Although the contributions of HPLC to other disciplines generally complements gas-liquid chromatography, this method is destined to play a much greater role in medical and biochemical research. This is because many of the biomolecules, owing to their molecular complexity and size, are thermally unstable or nonvolatile, preventing or complicating an analysis by GC. A major factor contributing to the powerful advances in biomedical liquid chromatography is the development of reversed-phase high-performance liquid chromatography (RP-HPLC) using n-alkyl and phenyl chemically bonded substrates.
Jiao, Lijin; Tao, Yanduo; Wang, Weidong; Shao, Yun; Mei, Lijuan; Wang, Qilan; Dang, Jun
2017-10-01
An offline preparative two-dimensional reversed-phase liquid chromatography/hydrophilic interaction liquid chromatography coupled with hydrophilic interaction solid-phase extraction method was developed for the preparative isolation of flavonoid glycosides from a crude sample of Sphaerophysa salsula. First, the non-flavonoids were removed using an XAmide solid-phase extraction cartridge. Based on the separation results of three different chromatographic stationary phases, the first-dimensional preparation was performed on an XAqua C18 prep column, and 15 fractions were obtained from the 5.2 g target sample. Then, three representative fractions were selected for additional purification on an XAmide preparative column to further isolate the flavonoid glycosides. In all, eight flavonoid glycosides were isolated in purities over 97%. The results demonstrated that the two-dimensional liquid chromatography method used in this study was effective for the preparative separation of flavonoid glycosides from Sphaerophysa salsula. Additionally, this method showed great potential for the separation of flavonoid glycosides from other plant materials. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Hetzel, Terence; Loeker, Denise; Teutenberg, Thorsten; Schmidt, Torsten C
2016-10-01
The efficiency of miniaturized liquid chromatography columns with inner diameters between 200 and 300 μm has been investigated using a dedicated micro-liquid chromatography system. Fully porous, core-shell and monolithic commercially available stationary phases were compared applying van Deemter and kinetic plot analysis. The sub-2 μm fully porous as well as the 2.7 μm core-shell particle packed columns showed superior efficiency and similar values for the minimum reduced plate heights (2.56-2.69) before correction for extra-column contribution compared to normal-bore columns. Moreover, the influence of extra-column contribution was investigated to demonstrate the difference between apparent and intrinsic efficiency by replacing the column by a zero dead volume union to determine the band spreading caused by the system. It was demonstrated that 72% of the intrinsic efficiency could be reached. The results of the kinetic plot analysis indicate the superior performance of the sub-2 μm fully porous particle packed column for ultra-fast liquid chromatography. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Hwang, Taeik; Noh, Eunyoung; Jeong, Ji Hye; Park, Sung-Kwan; Shin, Dongwoo; Kang, Hoil
2018-02-28
A sensitive and specific high-performance liquid chromatography-quadrupole time-of-flight-mass spectrometry (LC-QTOF-MS) method combined with liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed for the determination of grayanotoxins I and III in dietary supplements and homemade wine. Grayanotoxins I and III were successfully extracted using solid-phase extraction cartridges, characterized by LC-QTOF-MS, and quantitated by LC-MS/MS. The LC-MS/MS calibration curves were linear over concentrations of 10-100 ng/mL (grayanotoxin I) and 20-400 ng/mL (grayanotoxin III). Grayanotoxins I and III were found in 51 foodstuffs, with quantitative determinations revealing total toxin concentrations of 18.4-101 000 ng/mL (grayanotoxin I) and 15.3-56 000 ng/mL (grayanotoxin III). The potential of the validated method was demonstrated by successful quantitative analysis of grayanotoxins I and III in dietary supplements and homemade wine; the method appears suitable for the routine detection of grayanotoxins I and III from Rhododendron brachycarpum.
Li, Yuanyuan; Wei, Manman; Chen, Tong; Zhu, Nan; Ma, Yulong
2016-11-01
A facile strategy based on self-assembly of Au nanoparticles (AuNPs) (60±10nm in size) on the surfaces of amino-functionalized porous silica spheres under mild conditions was proposed. The resulting material possessed a core-shell structure in which AuNPs were the shell and silica spheres were the core. Then, thiolated-β-cyclodextrin (SH-β-CD) was covalently attached onto the AuNPs as chiral selector for the enantioseparation. The resultant packing material was evaluated by high-performance liquid chromatography (HPLC). The separations of nine pairs of enantiomers were achieved by using the new chiral stationary phase (CSP) in the reversed-phase liquid chromatography (RPLC) mode, respectively. The results showed the new CSP have more sufficient interaction with the analytes due to the existence of AuNPs on silica surfaces, resulting in faster mass transfer rate, compared with β-CD modified silica column. The result shed light on potential usage of chemical modified NPs as chiral selector for enantioseparation based on HPLC. In addition, the new phase was also used in hydrophilic interaction liquid chromatography (HILIC) to separate polar compounds and highly hydrophilic compounds. Copyright © 2016 Elsevier B.V. All rights reserved.
Zheng, Cao; Zhao, Jing; Bao, Peng; Gao, Jin; He, Jin
2011-06-24
A novel, simple and efficient dispersive liquid-liquid microextraction based on solidification of floating organic droplet (DLLME-SFO) technique coupled with high-performance liquid chromatography with ultraviolet detection (HPLC-UV) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed for the determination of triclosan and its degradation product 2,4-dichlorophenol in real water samples. The extraction solvent used in this work is of low density, low volatility, low toxicity and proper melting point around room temperature. The extractant droplets can be collected easily by solidifying it at a lower temperature. Parameters that affect the extraction efficiency, including type and volume of extraction solvent and dispersive solvent, salt effect, pH and extraction time, were investigated and optimized in a 5 mL sample system by HPLC-UV. Under the optimum conditions (extraction solvent: 12 μL of 1-dodecanol; dispersive solvent: 300 of μL acetonitrile; sample pH: 6.0; extraction time: 1 min), the limits of detection (LODs) of the pretreatment method combined with LC-MS/MS were in the range of 0.002-0.02 μg L(-1) which are lower than or comparable with other reported approaches applied to the determination of the same compounds. Wide linearities, good precisions and satisfactory relative recoveries were also obtained. The proposed technique was successfully applied to determine triclosan and 2,4-dichlorophenol in real water samples. Copyright © 2011 Elsevier B.V. All rights reserved.
Cheng, Heyong; Shen, Lihuan; Liu, Jinhua; Xu, Zigang; Wang, Yuanchao
2018-04-01
Nanoliter high-performance liquid chromatography shows low consumption of solvents and samples, offering one of the best choices for arsenic speciation in precious samples in combination with inuctively coupled plasma mass spectrometry. A systematic investigation on coupling nanoliter high-performance liquid chromatography to inductively coupled plasma mass spectrometry from instrument design to injected sample volume and mobile phase was performed in this study. Nanoflow mobile phase was delivered by flow splitting using a conventional high-pressure pump with reuse of mobile phase waste. Dead volume was minimized to 60 nL for the sheathless interface based on the previously developed nanonebulizer. Capillary columns for nanoliter high-performance liquid chromatography were found to be sensitive to sample loading volume. An apparent difference was also found between the mobile phases for nanoliter and conventional high-performance liquid chromatography. Baseline separation of arsenite, arsenate, monomethylarsenic, and dimethylarsenic was achieved within 11 min on a 15 cm C 18 capillary column and within 12 min on a 25 cm strong anion exchange column. Detection limits of 0.9-1.8 μg/L were obtained with precisions variable in the range of 1.6-4.2%. A good agreement between determined and certified values of a certified reference material of human urine (GBW 09115) validated its accuracy along with good recoveries (87-102%). © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Engida, Adam Mekonnen; Faika, Sitti; Nguyen-Thi, Bich Thuyen; Ju, Yi-Hsu
2015-06-01
In the present work, heat reflux extraction with ethanol/water (80:20; v/v) as the solvent was used to extract antioxidants from Myrmecodia pendans. The crude extract (CE) was fractionated using hexane and ethyl acetate. Ethyl acetate fraction (EAF) and aqueous fraction were collected. Antioxidant activity against 1,1-diphenyl-2-picrylhydrazyl-radical radical and ferric reducing power of the CE, EAF, and aqueous fraction were evaluated. EAF showed comparable antioxidant activity against 1,1-diphenyl-2-picrylhydrazyl-radical radical and ferric reducing power to those of the CE. UV/visible, liquid chromatography/electrospray ionization/tandem mass spectrometry, and high-performance liquid chromatography were employed for identifying the major antioxidant compounds in the EAF. Three major phenolic compounds (rosmarinic acid, procyanidin B1, and polymer of procyanidin B1) were identified. The first two compounds were confirmed and quantified by high-performance liquid chromatography using authentic standards, but confirmation of the third compound was hampered by a lack of commercial standard. Concentrations of rosmarinic acid and procyanidin B1 in the EAF were found to be 20.688 ± 1.573 mg/g dry sample and 3.236 ± 0.280 mg/g dry sample, respectively. All these three compounds are reported for the first time in sarang semut. Copyright © 2014. Published by Elsevier B.V.
Dinç, Erdal; Ertekin, Zehra Ceren; Büker, Eda
2016-09-01
Two-way and three-way calibration models were applied to ultra high performance liquid chromatography with photodiode array data with coeluted peaks in the same wavelength and time regions for the simultaneous quantitation of ciprofloxacin and ornidazole in tablets. The chromatographic data cube (tensor) was obtained by recording chromatographic spectra of the standard and sample solutions containing ciprofloxacin and ornidazole with sulfadiazine as an internal standard as a function of time and wavelength. Parallel factor analysis and trilinear partial least squares were used as three-way calibrations for the decomposition of the tensor, whereas three-way unfolded partial least squares was applied as a two-way calibration to the unfolded dataset obtained from the data array of ultra high performance liquid chromatography with photodiode array detection. The validity and ability of two-way and three-way analysis methods were tested by analyzing validation samples: synthetic mixture, interday and intraday samples, and standard addition samples. Results obtained from two-way and three-way calibrations were compared to those provided by traditional ultra high performance liquid chromatography. The proposed methods, parallel factor analysis, trilinear partial least squares, unfolded partial least squares, and traditional ultra high performance liquid chromatography were successfully applied to the quantitative estimation of the solid dosage form containing ciprofloxacin and ornidazole. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Baghdady, Yehia Z; Schug, Kevin A
2016-01-01
Accurate and specific analysis of target molecules in complex biological matrices remains a significant challenge, especially when ultra-trace detection limits are required. Liquid chromatography with mass spectrometry is often the method of choice for bioanalysis. Conventional sample preparation and clean-up methods prior to the analysis of biological fluids such as liquid-liquid extraction, solid-phase extraction, or protein precipitation are time-consuming, tedious, and can negatively affect target recovery and detection sensitivity. An alternative or complementary strategy is the use of an off-line or on-line in situ derivatization technique. In situ derivatization can be incorporated to directly derivatize target analytes in their native biological matrices, without any prior sample clean-up methods, to substitute or even enhance the extraction and preconcentration efficiency of these traditional sample preparation methods. Designed appropriately, it can reduce the number of sample preparation steps necessary prior to analysis. Moreover, in situ derivatization can be used to enhance the performance of the developed liquid chromatography with mass spectrometry-based bioanalysis methods regarding stability, chromatographic separation, selectivity, and ionization efficiency. This review presents an overview of the commonly used in situ derivatization techniques coupled to liquid chromatography with mass spectrometry-based bioanalysis to guide and to stimulate future research. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Kubica, Paweł; Wasik, Andrzej; Kot-Wasik, Agata; Namieśnik, Jacek
2014-05-01
The influence of sucrose combustion products on smoking and nicotine addiction is still controversial because the presence of the sucrose may be treated as a source of aldehydes and organic acids. In e-liquids used as refills for electronic cigarettes, which are made primarily of poly(propylene glycol), glycerine and ethanol, sucrose may be present at trace levels, and its impact on mainstream smoke formation, and hence on human health and smoking/nicotine addiction is unknown. An analytical method was developed where high-performance liquid chromatography in hydrophilic interaction liquid chromatography mode and tandem mass spectrometry were used for fast and simple determination of sucrose and other saccharides in e-liquids for electronic cigarettes. Minimal effort was required in the sample preparation step, and satisfactory results were obtained, and the sample matrix had an insignificant impact. The chromatographic separation was done using an Ascentis Express OH5 column (150 mm × 2.1 mm, 2.7 μm). The coefficients of variation for within-day precision for three concentrations were 2.4 %, 1.6 % and 2.3 %, and the between-day coefficients of variation for a single concentration were 2.1 %, 2.5 % and 1.7 % measured on the next 3 days. The detection limit was 0.73 μg/g, and the sucrose content in e-liquids ranged from 0.76 to 72.93 μg/g among 37 samples. Moreover, with the method presented it is possible to determine the presence of other saccharides such as fructose, glucose, maltose and lactose. However, only sucrose was found in all samples of e-liquids. The proposed method is rapid, simple and reliable in terms of high-performance liquid chromatography coupled with tandem mass spectrometry.
Sarafian, Magali H; Lewis, Matthew R; Pechlivanis, Alexandros; Ralphs, Simon; McPhail, Mark J W; Patel, Vishal C; Dumas, Marc-Emmanuel; Holmes, Elaine; Nicholson, Jeremy K
2015-10-06
Bile acids are important end products of cholesterol metabolism. While they have been identified as key factors in lipid emulsification and absorption due to their detergent properties, bile acids have also been shown to act as signaling molecules and intermediates between the host and the gut microbiota. To further the investigation of bile acid functions in humans, an advanced platform for high throughput analysis is essential. Herein, we describe the development and application of a 15 min UPLC procedure for the separation of bile acid species from human biofluid samples requiring minimal sample preparation. High resolution time-of-flight mass spectrometry was applied for profiling applications, elucidating rich bile acid profiles in both normal and disease state plasma. In parallel, a second mode of detection was developed utilizing tandem mass spectrometry for sensitive and quantitative targeted analysis of 145 bile acid (BA) species including primary, secondary, and tertiary bile acids. The latter system was validated by testing the linearity (lower limit of quantification, LLOQ, 0.25-10 nM and upper limit of quantification, ULOQ, 2.5-5 μM), precision (≈6.5%), and accuracy (81.2-118.9%) on inter- and intraday analysis achieving good recovery of bile acids (serum/plasma 88% and urine 93%). The ultra performance liquid chromatography-mass spectrometry (UPLC-MS)/MS targeted method was successfully applied to plasma, serum, and urine samples in order to compare the bile acid pool compositional difference between preprandial and postprandial states, demonstrating the utility of such analysis on human biofluids.
Chen, Ming-Jen; Liu, Ya-Ting; Lin, Chiao-Wen; Ponnusamy, Vinoth Kumar; Jen, Jen-Fon
2013-03-12
This paper describes the development of a novel, simple and efficient in-tube based ultrasound-assisted salt-induced liquid-liquid microextraction (IT-USA-SI-LLME) technique for the rapid determination of triclosan (TCS) in personal care products by high performance liquid chromatography-ultraviolet (HPLC-UV) detection. IT-USA-SI-LLME method is based on the rapid phase separation of water-miscible organic solvent from the aqueous phase in the presence of high concentration of salt (salting-out phenomena) under ultrasonication. In the present work, an indigenously fabricated home-made glass extraction device (8-mL glass tube inbuilt with a self-scaled capillary tip) was utilized as the phase separation device for USA-SI-LLME. After the extraction, the upper extractant layer was narrowed into the self-scaled capillary tip by pushing the plunger plug; thus, the collection and measurement of the upper organic solvent layer was simple and convenient. The effects of various parameters on the extraction efficiency were thoroughly evaluated and optimized. Under optimal conditions, detection was linear in the concentration range of 0.4-100ngmL(-1) with correlation coefficient of 0.9968. The limit of detection was 0.09ngmL(-1) and the relative standard deviations ranged between 0.8 and 5.3% (n=5). The applicability of the developed method was demonstrated for the analysis of TCS in different commercial personal care products and the relative recoveries ranged from 90.4 to 98.5%. The present method was proven to be a simple, sensitive, less organic solvent consuming, inexpensive and rapid procedure for analysis of TCS in a variety of commercially available personal care products or cosmetic preparations. Copyright © 2013 Elsevier B.V. All rights reserved.
Evidence of VX nerve agent use from contaminated white mustard plants
Gravett, Matthew R.; Hopkins, Farrha B.; Self, Adam J.; Webb, Andrew J.; Timperley, Christopher M.; Baker, Matthew J.
2014-01-01
The Chemical Weapons Convention prohibits the development, production, acquisition, stockpiling, retention, transfer or use of chemical weapons by Member States. Verification of compliance and investigations into allegations of use require accurate detection of chemical warfare agents (CWAs) and their degradation products. Detection of CWAs such as organophosphorus nerve agents in the environment relies mainly upon the analysis of soil. We now present a method for the detection of the nerve agent VX and its hydrolysis products by gas chromatography and liquid chromatography mass spectrometry of ethanol extracts of contaminated white mustard plants (Sinapis alba) which retained the compounds of interest for up to 45 days. VX is hydrolysed by the plants to ethyl methylphosphonic acid and then to methylphosphonic acid. The utility of white mustard as a nerve agent detector and remediator of nerve agent-polluted sites is discussed. The work described will help deter the employment of VX in conflict. PMID:25104906
DOE Office of Scientific and Technical Information (OSTI.GOV)
Swarin, S.J.; Loo, J.F.; Chladek, E.
1992-01-01
Analytical methods for determining individual aldehyde, ketone, and alcohol emissions from gasoline-, methanol-, and variable-fueled vehicles are described. These methods were used in the Auto/Oil Air Quality Improvement Research Program to provide emission data for comparison of individual reformulated fuels, individual vehicles, and for air modeling studies. The emission samples are collected in impingers which contain either 2,4-dinitrophenylhydrazine solution for the aldehydes and ketones or deionized water for the alcohols. Subsequent analyses by liquid chromatography for the aldehydes and ketones and gas chromatography for the alcohols utilized auto injectors and computerized data systems which permit high sample throughput with minimalmore » operator intervention. The quality control procedures developed and interlaboratory comparisons conducted as part of the program are also described. (Copyright (c) 1992 Society of Automotive Engineers, Inc.)« less
Activation of Reactive MALDI Adduct Ions Enables Differentiation of Dihydroxylated Vitamin D Isomers
NASA Astrophysics Data System (ADS)
Qi, Yulin; Müller, Miriam J.; Volmer, Dietrich A.
2017-12-01
Vitamin D compounds are secosteroids, which are best known for their role in bone health. More recent studies have shown that vitamin D metabolites and catabolites such as dihydroxylated species (e.g., 1,25- and 24,25-dihydroxyvitamin D3) play key roles in the pathologies of various diseases. Identification of these isomers by mass spectrometry is challenging and currently relies on liquid chromatography, as the isomers exhibit virtually identical product ion spectra under collision induced dissociation conditions. Here, we developed a simple MALDI-CID method that utilizes ion activation of reactive analyte/matrix adducts to distinguish isomeric dihydroxyvitamin D3 species, without the need for chromatography separation or chemical derivatization techniques. Specifically, reactive 1,5-diaminonaphthalene adducts of dihydroxyvitamin D3 compounds formed during MADI were activated and specific cleavages in the secosteroid's backbone structure were achieved that produced isomer-diagnostic fragment ions. [Figure not available: see fulltext.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kertesz, Vilmos; Van Berkel, Gary J
A fully automated liquid extraction-based surface sampling system utilizing a commercially available autosampler coupled to high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) detection is reported. Discrete spots selected for droplet-based sampling and automated sample queue generation for both the autosampler and MS were enabled by using in-house developed software. In addition, co-registration of spatially resolved sampling position and HPLC-MS information to generate heatmaps of compounds monitored for subsequent data analysis was also available in the software. The system was evaluated with whole-body thin tissue sections from propranolol dosed rat. The hands-free operation of the system was demonstrated by creating heatmapsmore » of the parent drug and its hydroxypropranolol glucuronide metabolites with 1 mm resolution in the areas of interest. The sample throughput was approximately 5 min/sample defined by the time needed for chromatographic separation. The spatial distributions of both the drug and its metabolites were consistent with previous studies employing other liquid extraction-based surface sampling methodologies.« less
Liu, Yong-Qiang; Yu, Hong
2017-04-01
A convenient and versatile method was developed for the separation and detection of alkaline earth metal ions by ion chromatography with indirect UV detection. The chromatographic separation of Mg 2+ , Ca 2+ , and Sr 2+ was performed on a carboxylic acid base cation exchange column using imidazolium ionic liquid/acid as the mobile phase, in which the imidazolium ionic liquid acted as an UV-absorption reagent. The effects of imidazolium ionic liquids, detection wavelength, acids in the mobile phase, and column temperature on the retention of Mg 2+ , Ca 2+ , and Sr 2+ were investigated. The main factors influencing the separation and detection were the background UV absorption reagent and the concentration of hydrogen ion in ion chromatography with indirect UV detection. The successful separation and detection of Mg 2+ , Ca 2+ , and Sr 2+ within 14 min were achieved using the selected chromatographic conditions, and the detection limits (S/N = 3) were 0.06, 0.12, and 0.23 mg/L, respectively. A new separation and detection method of alkaline earth metal ions by ion chromatography with indirect UV detection was developed, and the application range of ionic liquids was expanded. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Analytical methodologies for broad metabolite coverage of exhaled breath condensate.
Aksenov, Alexander A; Zamuruyev, Konstantin O; Pasamontes, Alberto; Brown, Joshua F; Schivo, Michael; Foutouhi, Soraya; Weimer, Bart C; Kenyon, Nicholas J; Davis, Cristina E
2017-09-01
Breath analysis has been gaining popularity as a non-invasive technique that is amenable to a broad range of medical uses. One of the persistent problems hampering the wide application of the breath analysis method is measurement variability of metabolite abundances stemming from differences in both sampling and analysis methodologies used in various studies. Mass spectrometry has been a method of choice for comprehensive metabolomic analysis. For the first time in the present study, we juxtapose the most commonly employed mass spectrometry-based analysis methodologies and directly compare the resultant coverages of detected compounds in exhaled breath condensate in order to guide methodology choices for exhaled breath condensate analysis studies. Four methods were explored to broaden the range of measured compounds across both the volatile and non-volatile domain. Liquid phase sampling with polyacrylate Solid-Phase MicroExtraction fiber, liquid phase extraction with a polydimethylsiloxane patch, and headspace sampling using Carboxen/Polydimethylsiloxane Solid-Phase MicroExtraction (SPME) followed by gas chromatography mass spectrometry were tested for the analysis of volatile fraction. Hydrophilic interaction liquid chromatography and reversed-phase chromatography high performance liquid chromatography mass spectrometry were used for analysis of non-volatile fraction. We found that liquid phase breath condensate extraction was notably superior compared to headspace extraction and differences in employed sorbents manifested altered metabolite coverages. The most pronounced effect was substantially enhanced metabolite capture for larger, higher-boiling compounds using polyacrylate SPME liquid phase sampling. The analysis of the non-volatile fraction of breath condensate by hydrophilic and reverse phase high performance liquid chromatography mass spectrometry indicated orthogonal metabolite coverage by these chromatography modes. We found that the metabolite coverage could be enhanced significantly with the use of organic solvent as a device rinse after breath sampling to collect the non-aqueous fraction as opposed to neat breath condensate sample. Here, we show the detected ranges of compounds in each case and provide a practical guide for methodology selection for optimal detection of specific compounds. Copyright © 2017 Elsevier B.V. All rights reserved.
Application of ionic liquids in liquid chromatography and electrodriven separation.
Huang, Yi; Yao, Shun; Song, Hang
2013-08-01
Ionic liquids (ILs) are salts in the liquid state at ambient temperature, which are nonvolatile, nonflammable with high thermal stability and dissolve easily for a wide range of inorganic and organic materials. As a kind of potential green solvent, they show high efficiency and selectivity in the field of separation research, especially in instrumental analysis. Thus far, ILs have been successfully applied by many related researchers in high-performance liquid chromatography and capillary electrophoresis as chromatographic stationary phases, mobile phase additives or electroosmotic flow modifiers. This paper provides a detailed review of these applications in the study of natural products, foods, drugs and other fine chemicals. Furthermore, the prospects of ILs in liquid chromatographic and electrodriven techniques are discussed.
Zhang, X; Young, L Y
1997-01-01
The anaerobic biodegradation of naphthalene (NAP) and phenanthrene (PHE) was investigated by using sediment collected from the Arthur Kill in New York/New Jersey harbor. The initial cultures were composed of 10% sediment and 90% mineral medium containing 20 mM sulfate. Complete loss of NAP and PHE (150 to 200 muM) was observed after 150 days of incubation. Upon refeeding, NAP and PHE were utilized within 14 days. The utilization of both compounds was inhibited in the presence of 20 mM molybdate. [14C]NAP and [14C]PHE were mineralized to 14CO2. The activities could be maintained and propagated by subculturing in mineral medium. In the presence of halogenated analogs, 2-naphthoate was detected in NAP-utilizing enrichments. The mass spectrum of the derivatized 2-napththoate from the enrichment supplemented with both [13C]bicarbonate and NAP indicates the incorporation of 13CO2 into NAP. In the PHE-utilizing enrichment, a metabolite was detected by both high-pressure liquid chromatography and gas chromatography-mass spectrometry analyses. The molecular ion and fragmentation pattern of its mass spectrum indicate that it was phenanthrenecarboxylic acid. The results obtained with [13C] bicarbonate indicate that 13CO2 was incorporated into PHE. It appears, therefore, that carboxylation is an initial key reaction for the anaerobic metabolism and NAP and PHE. To our knowledge, this is the first report providing evidence for intermediates of PAH degradation under anaerobic conditions. PMID:9471963
USDA-ARS?s Scientific Manuscript database
In this study, optimization, extension, and validation of a streamlined, qualitative and quantitative multiclass, multiresidue method was conducted to monitor great than100 veterinary drug residues in meat using ultrahigh-performance liquid chromatography – tandem mass spectrometry (UHPLC-MS/MS). I...
ERIC Educational Resources Information Center
Stock, Naomi L.; Martin, Jonathan W.; Ye, Yun; Mabury, Scott A.
2007-01-01
A laboratory experiment that provides students a hands-on introduction to the specific techniques of liquid chromatography-tandem mass spectrometry (LC-MS/MS) and electrospray ionization is presented. The students can thus practice the analytical principles of sample extraction, detection, quantification, and quality control using a fresh fish…
USDA-ARS?s Scientific Manuscript database
Glyceollin-related metabolites produced in rats following oral glyceollin administration were screened and identified by precursor and product ion scanning using liquid chromatography, coupled on-line with electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS), to identify all glyceollin me...
Fragrance materials such as synthetic musks in aqueous samples, are normally determined by gas chromatography/mass spectrometry in the selected ion monitoring (SIM) mode to provide maximum sensitivity after liquid-liquid extraction of I -L samples. Full-scan mass spectra are requ...
USDA-ARS?s Scientific Manuscript database
A selective ultra-high performance liquid chromatography-didode array detector-quadrapole time of flight-mass spectrometry (UHPLC-DAD-QToF-MS) method has been developed to screen grapefruit seeds, and other citrus seed samples for limonoid aglycones, limonoid acids, limonoid glucosides and flavonoid...
USDA-ARS?s Scientific Manuscript database
An ultra-high performance liquid chromatography-ion mobility- quadrupole time-of-flight mass spectrometry (UHPLC-IM-QTOF-MS) method was developed for profiling the indole alkaloids in yohimbe bark. Many indole alkaloids with the yohimbine core structure, plus methylated, oxidized, and reduced speci...
Benzoin Condensation: Monitoring a Chemical Reaction by High-Pressure Liquid Chromatography
ERIC Educational Resources Information Center
Bhattacharya, Apurba; Purohit, Vikram C.; Bellar, Nicholas R.
2004-01-01
High-pressure liquid chromatography (HPLC) is the preferred method of separating a variety of materials in complex mixtures such as pharmaceuticals, polymers, soils, food products and biological fluids and is also considered to be a powerful analytical tool in both academia and industry. The use of HPLC analysis as a means of monitoring and…
USDA-ARS?s Scientific Manuscript database
The lack of a biomarker for the consumption of cranberries has confounded the interpretation of several studies investigating the effect of cranberry products, especially juices, on health outcomes. The objectives of this pilot study were to develop a liquid chromatography tandem mass spectrometric ...
ERIC Educational Resources Information Center
Leacock, Rachel E.; Stankus, John J.; Davis, Julian M.
2011-01-01
A high-performance liquid chromatography experiment to determine the concentration of caffeine and vitamin B6 in sports energy drinks has been developed. This laboratory activity, which is appropriate for an upper-level instrumental analysis course, illustrates the standard addition method and simultaneous determination of two species. (Contains 1…
ERIC Educational Resources Information Center
Penteado, Jose C.; Masini, Jorge Cesar
2011-01-01
Influence of the solvent strength determined by the addition of a mobile-phase organic modifier and pH on chromatographic separation of sorbic acid and vanillin has been investigated by the relatively new technique, liquid sequential injection chromatography (SIC). This technique uses reversed-phase monolithic stationary phase to execute fast…
Determination of sugars in honey by liquid chromatography
Kamal, Mohammad A.; Klein, Peter
2010-01-01
Honey is a rich conventional natural resource of sweetness and energy for human beings. A protocol for the determination of two important monosaccharide sugars (fructose and glucose) in honey was established in the current study by using normal phase partition liquid chromatography and 1–5% combined working standard of glucose, fructose and sucrose. PMID:23961099
NASA Technical Reports Server (NTRS)
Fahey, Robert C.; Newton, Gerald L.
1988-01-01
Methods are described for the preparation and high-performance liquid chromatography (HPLC) analysis of monobromobimane derivatives of low molecular weight thiols in extracts of biological samples. Typical problems encountered in the development and application of these methods are discussed. Analysis of mung bean extract is used as an example.
NASA Technical Reports Server (NTRS)
Worstell, J. H.; Daniel, S. R.
1981-01-01
A method for the separation and analysis of tetralin hydroperoxide and its decomposition products by high pressure liquid chromatography has been developed. Elution with a single, mixed solvent from a micron-Porasil column was employed. Constant response factors (internal standard method) over large concentration ranges and reproducible retention parameters are reported.
The formation of methylarsonous acid (MAsIII) and dimethylarsinous acid (DMAsIII) in the course of inorganic arsenic (iAs) metabolism plays an important role in the adverse effects of chronic exposure to iAs. High-performance liquid chromatography-inductively coupled plasma-mass ...
Kayillo, Sindy; Gray, Michael J; Shalliker, R Andrew; Dennis, Gary R
2005-05-06
Isotopic substitution is a technique used to highlight particular bonds within a molecule for kinetic, spectroscopic and structure analysis. It is presumed that although some properties such as stretching frequencies will not be the same for substituted analogues, the chemical interactions will not vary appreciably as a function of labelling. Reversed-phase liquid chromatography has been used to demonstrate that there are significant differences between the chromatographic behaviour of a sequence of deuterated and protonated oligomeric polystyrenes. Two-dimensional reversed-phase liquid chromatography was used to show that even the diasteromers of the oligomers (n = 5) have retention mechanisms that are dependent on the subtle changes to the molecular conformation and electronic structure, which are a consequence of deuteration.
Principles and Applications of Liquid Chromatography-Mass Spectrometry in Clinical Biochemistry
Pitt, James J
2009-01-01
Liquid chromatography-mass spectrometry (LC-MS) is now a routine technique with the development of electrospray ionisation (ESI) providing a simple and robust interface. It can be applied to a wide range of biological molecules and the use of tandem MS and stable isotope internal standards allows highly sensitive and accurate assays to be developed although some method optimisation is required to minimise ion suppression effects. Fast scanning speeds allow a high degree of multiplexing and many compounds can be measured in a single analytical run. With the development of more affordable and reliable instruments, LC-MS is starting to play an important role in several areas of clinical biochemistry and compete with conventional liquid chromatography and other techniques such as immunoassay. PMID:19224008
Ha, Steven T.K.; Wilkins, Charles L.; Abidi, Sharon L.
1989-01-01
A mixture of closely related streptomyces fermentation products, antimycin A, Is separated, and the components are identified by using reversed-phase high-performance liquid chromatography with directly linked 400-MHz proton nuclear magnetic resonance detection. Analyses of mixtures of three amino acids, alanine, glycine, and valine, are used to determine optimal measurement conditions. Sensitivity increases of as much as a factor of 3 are achieved, at the expense of some loss in chromatographic resolution, by use of an 80-μL NMR cell, Instead of a smaller 14-μL cell. Analysis of the antimycin A mixture, using the optimal analytical high performance liquid chromatography/nuclear magnetic resonance conditions, reveals it to consist of at least 10 closely related components.
Sandra, Koen; Moshir, Mahan; D'hondt, Filip; Tuytten, Robin; Verleysen, Katleen; Kas, Koen; François, Isabelle; Sandra, Pat
2009-04-15
Multidimensional liquid-based separation techniques are described for maximizing the resolution of the enormous number of peptides generated upon tryptic digestion of proteomes, and hence, reduce the spatial and temporal complexity of the sample to a level that allows successful mass spectrometric analysis. This review complements the previous contribution on unidimensional high performance liquid chromatography (HPLC). Both chromatography and electrophoresis will be discussed albeit with reversed-phase HPLC (RPLC) as the final separation dimension prior to MS analysis.
Ma, Shufeng; Hu, Liming; Ma, Chaoyang; Lv, Wenping; Wang, Hongxin
2014-09-01
A novel on-line three-dimensional liquid chromatography method was developed to separate four main flavonoids from Rhodiola rosea. Ethyl acetate/0.5 mol/L ionic liquid 1-butyl-3-methylimidazolium chloride aqueous solution was selected as the solvent system. In the first-dimension separation, the target flavonoids were entrapped and subsequently desorbed into the second-dimension high-speed countercurrent chromatographic column for separation. In the third-dimension chromatography, the residual ionic liquid in the four separated flavonoids was removed and the used ionic liquid was recovered. As a result, 35.1 mg of compound 1, 20.4 mg of compound 2, 8.5 mg of compound 3, and 10.6 mg of compound 4 were obtained from 1.53 g R. rosea extract. They were identified as rhodiosin, rhodionin, herbacetin, and kaempferol, respectively. The recovery of ionic liquid reached 99.1% of the initial amount. The results showed that this method is a powerful technology for the separation of R. rosea flavonoids and that the ionic-liquid-based solvent system has advantages over traditional solvent systems in renewable and environmentally friendly properties. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Ellingson, David J; Shippar, Jeffrey J; Gilmore, Justin M
2016-01-01
Analytical methods for the analysis of both L-carnitine and choline are needed for reliable and accurate determination in infant formula and adult/pediatric nutritional formula. These compounds are different in how they are utilized by the human body, but are structurally similar. L-carnitine and choline are quaternary ammonium compounds, enabling both to be retained under acidic conditions with strong cation exchange (SCX) chromatography. This method analyzes both compounds simultaneously as either the free forms or as a total amount that includes bound sources such as phosphatidylcholine or acetylcarnitine. The free analysis consists of water extraction and analysis by LC/MS/MS, while the total analysis consists of extraction by acid assisted microwave hydrolysis and analysis by LC/MS/MS. Calibration standards used for calculations are extracted with all samples in the batch. A single laboratory validation (SLV) was performed following the guidelines of the AOAC Stakeholder Panel on Infant Formula and Adult Nutritionals (SPIFAN) utilizing the kit of materials provided. The results achieved meet the requirements of SMPR 2012.010 and 2012.013 for L-carnitine and total choline, respectively.
Ergosterol from the soilborne fungus Ganoderma boninense.
Toh Choon, R L; Sariah, M; Siti Mariam, M N
2012-10-01
Ergosterol is the main component of the fungal membrane and is not found in plants or other microbial cells. Therefore, it can be a useful biomarker for the quantification of fungal biomass. We are now reporting the first isolation and characterisation of ergosterol from the mycelium of G. boninense. The ergosterol structure was detected by Thin Liquid Chromatography (TLC) and Ultra Performance Liquid Chromatography (UPLC) and confirmed with Gas Chromatography coupled with Mass Spectrometry (GCMS) and Nuclear Magnetic Resonance (NMR) analysis. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Giuffrida, Daniele; Donato, Paola; Dugo, Paola; Mondello, Luigi
2018-04-04
In the present perspective, different approaches to the carotenoids analysis will be discussed providing a brief overview of the most advanced both monodimensional and bidimensional liquid chromatographic methodologies applied to the carotenoids analysis, followed by a discussion on the recents advanced supercritical fluid chromatography × liquid chromatography bidimensional approach with photodiode-array and mass spectrometry detection. Moreover a discussion on the online supercritical fluid extraction-supercritical fluid chromatography with tandem mass spectrometry detection applied to the determination of carotenoids and apocarotenoids will also be provided.
Pietta, P; Bruno, A; Mauri, P; Rava, A
1992-02-28
Calendula officinalis and Sambucus nigra flowers were analysed by reversed-phase high-performance liquid chromatography (RP-HPLC) and micellar electrokinetic capillary chromatography (MECC). RP-HPLC was performed on C8 Aquapore RP 300 columns with eluents containing 2-propanol and tetrahydrofuran. MECC was carried out on a 72-cm fused-silica capillary using sodium dodecyl sulphate and sodium borate (pH 8.3) as the running buffer. The results obtained by these techniques are compared.
Wang, Jing; Zheng, Meizhu; Chen, Lina; Liu, Zhiqiang; Zhang, Yuchi; Liu, Chun-Ming; Liu, Shu
2016-11-01
Hydroxyl radicals are the most reactive free radical of human body, a strong contributor to tissue damage. In this study, liquid chromatography coupled to electrospray ionization mass spectrometry was applied to screen and identify hydroxyl radical scavengers from the total flavonoids of Ginkgo biloba leaves, and high-performance counter current chromatography was used to separate and isolate the active compounds. Furthermore, molecular devices were used to determine hydroxyl radical scavenging activities of the obtained hydroxyl radical scavengers and other flavonoids from G. biloba leaves. As a result, six compounds were screened as hydroxyl radical scavengers, but only three flavonoids, namely, rutin, cosmos glycosides and apigenin-7-O-Glu-4'-O-Rha, were isolated successfully from total flavonoids by high-performance counter current chromatography. The purities of the three obtained compounds were over 90%, respectively, as determined by liquid chromatography. Molecular devices with 96-well microplates evaluation indicated that the 50% scavenging concentration values of screened compounds were lower than that of other flavonoids, they performed greater hydroxyl radical scavenging activity, and the evaluation effects were consistent with the liquid chromatography with mass spectrometry screening results. Therefore, chromatography combined with molecular devices is a feasible and an efficient method for systematic screening, identification, isolation, and evaluation of bioactive components in mixture of botanical medicines. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Li, Ting Yu; Huo, Xiao Kui; Zheng, Lu; Wang, Chao; Cong, Hai Jian; Xiang, Ting; Zhang, Lin; Zhang, Bao Jing; Huang, Shan Shan; Wu, Bin; Li, Xin Yu
2017-01-01
Background: Chaiqin Qingning Capsule (CQQNC) was a prescription of Traditional Chinese Medicine with the effects of clearing away heat and removing toxin, harmonizing the exterior and interior, it was widely used in Asian, for example, China and Japan, different batches of the raws materials and different processing time may be the vital factor which raised a challenge to control the quality of the CQQNC. Experimental Methods: In this experiment, a high-performance liquid chromatography-mass spectrometry/MS (HPLC-MS/MS) method was developed to simultaneously determine ten bioactive components for the quality control of CQQNC. Chromatographic separation was achieved using an XBridge BEH C18 column (150 mm × 4.6 mm, 2.5 μm) with a mobile phase composed of 10 mm aqueous ammonium acetate and acetonitrile using a gradient elution in 20 min. This study was conducted by multiple reaction monitoring mode through electrospray ionization resource with a negative ionization mode. Results: The established method was validated with good performance of precision, accuracy, stability, and reproducibility and was utilized to simultaneously quantify ten constituents of CQQNC obtained from seven different batches. Conclusion: It is the first time to report the rapid and simultaneous analysis of the ten compounds in CQQNC by HPLC-MS/MS and apply to determine 10 constituents in 7 batches of CQQNC bought from drug store in china. This method could be considered as good quality criteria to control the quality of CQQNC. SUMMARY In this paper, a simple, specific, and rapid high-performance liquid chromatogram coupled with triple-quadrupole mass spectrometry method for simultaneous quantification of ten constituents in Chaiqin Qingning Capsule has been developed for the first time. This method could be considered as good quality criteria to control the quality of CQQNC. Abbreviations used: CHM: Chinese herbal medicine; TCM: Traditional Chinese Medicine; CQQNC: Triple-quadrupole mass spectrometry Chaiqin Qingning Capsules; HPLC–MS/MS: High liquid chromatography equipped with tandem mass spectrometry; ESI: Electrospray ionization; DP: Declustering potential; CE: Collision energy; RSD: Relative standard deviation; LOD: Limit of detection; LOQ: Limit of quantity. PMID:29200714
Li, Ting Yu; Huo, Xiao Kui; Zheng, Lu; Wang, Chao; Cong, Hai Jian; Xiang, Ting; Zhang, Lin; Zhang, Bao Jing; Huang, Shan Shan; Wu, Bin; Li, Xin Yu
2017-01-01
Chaiqin Qingning Capsule (CQQNC) was a prescription of Traditional Chinese Medicine with the effects of clearing away heat and removing toxin, harmonizing the exterior and interior, it was widely used in Asian, for example, China and Japan, different batches of the raws materials and different processing time may be the vital factor which raised a challenge to control the quality of the CQQNC. In this experiment, a high-performance liquid chromatography-mass spectrometry/MS (HPLC-MS/MS) method was developed to simultaneously determine ten bioactive components for the quality control of CQQNC. Chromatographic separation was achieved using an XBridge BEH C18 column (150 mm × 4.6 mm, 2.5 μm) with a mobile phase composed of 10 mm aqueous ammonium acetate and acetonitrile using a gradient elution in 20 min. This study was conducted by multiple reaction monitoring mode through electrospray ionization resource with a negative ionization mode. The established method was validated with good performance of precision, accuracy, stability, and reproducibility and was utilized to simultaneously quantify ten constituents of CQQNC obtained from seven different batches. It is the first time to report the rapid and simultaneous analysis of the ten compounds in CQQNC by HPLC-MS/MS and apply to determine 10 constituents in 7 batches of CQQNC bought from drug store in china. This method could be considered as good quality criteria to control the quality of CQQNC. In this paper, a simple, specific, and rapid high-performance liquid chromatogram coupled with triple-quadrupole mass spectrometry method for simultaneous quantification of ten constituents in Chaiqin Qingning Capsule has been developed for the first time. This method could be considered as good quality criteria to control the quality of CQQNC. Abbreviations used: CHM: Chinese herbal medicine; TCM: Traditional Chinese Medicine; CQQNC: Triple-quadrupole mass spectrometry Chaiqin Qingning Capsules; HPLC-MS/MS: High liquid chromatography equipped with tandem mass spectrometry; ESI: Electrospray ionization; DP: Declustering potential; CE: Collision energy; RSD: Relative standard deviation; LOD: Limit of detection; LOQ: Limit of quantity.
Luo, Haibin; Lee, Nacole; Wang, Xiangyang; Li, Yuling; Schmelzer, Albert; Hunter, Alan K; Pabst, Timothy; Wang, William K
2017-03-10
Turbid elution pools and high column back pressure are common during elution of monoclonal antibodies (mAbs) by acidic pH in Protein A chromatography. This phenomenon has been historically attributed to acid-induced precipitation of incorrectly folded or pH-sensitive mAbs and host cell proteins (HCPs). In this work, we propose a new mechanism that may account for some observations of elution turbidity in Protein A chromatography. We report several examples of turbidity and high column back pressure occurring transiently under a short course of neutral conditions during Protein A elution. A systematic study of three mAbs displaying this behavior revealed phase separation characterized by liquid drops under certain conditions including neutral pH, low ionic strength, and high protein concentration. These liquid droplets caused solution turbidity and exhibited extremely high viscosity, resulting in high column back pressure. We found out that the droplets were formed through liquid-liquid phase separation (LLPS) as a result of protein self-association. We also found multiple factors, including pH, temperature, ionic strength, and protein concentration can affect LLPS behaviors. Careful selection of process parameters during protein A elution, including temperature, flow rate, buffer, and salt can inhibit formation of a dense liquid phase, reducing both turbidity (by 90%) and column back pressure (below 20 pounds per square inch). These findings provide both mechanistic insight and practical mitigation strategies for Protein A chromatography induced LLPS. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.
Yan, Cheing-Tong; Chien, Hai-Ying
2012-07-13
In this study, a simple and novel one-step hollow-fiber supported liquid-phase sampling (HF-LPS) technique was developed for enriched sampling of gaseous toxic species prior to chemical analysis for workplace air monitoring. A lab-made apparatus designed with a gaseous sample generator and a microdialysis sampling cavity (for HF-LPS) was utilized and evaluated to simulate gaseous contaminant air for occupational workplace analysis. Gaseous phenol was selected as the model toxic species. A polyethersulfone hollow fiber dialysis module filled with ethylene glycol in the shell-side was applied as the absorption solvent to collect phenol from a gas flow through the tube-side, based on the concentration distribution of phenol between the absorption solvent and the gas flow. After sampling, 20 μL of the extractant was analyzed by high performance liquid chromatography with ultraviolet detection (HPLC-UV). Factors that influence the generation of gaseous standards and the HF-LPS were studied thoroughly. Results indicated that at 25 °C the phenol (2000 μg/mL) standard solution injected at 15-μL/min can be vaporized into sampling cavity under nitrogen flow at 780 mL/min, to generate gaseous phenol with concentration approximate to twice the permissible exposure limit. Sampling at 37.3 mL/min for 30 min can meet the requirement of the workplace air monitoring. The phenol in air ranged between 0.7 and 10 cm³/m³ (shows excellent linearity) with recovery between 98.1 and 104.1%. The proposed method was identified as a one-step sampling for workplace monitoring with advantages of convenience, rapidity, sensitivity, and usage of less-toxic solvent. Copyright © 2012 Elsevier B.V. All rights reserved.
Tölgyesi, Adám; Sharma, Virender K; Fekete, Jeno
2011-02-15
A new method was developed to determine five corticosteroids (prednisolone, methylprednisone, flumethasone, dexamethasone, and methylprednisolone) in pig fat samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS) utilizing an optimized liquid-liquid extraction (LLE) and subsequent solid-phase extraction (SPE) for sample clean-up. In the sample preparation, a pig fat sample was dissolved in n-hexane and then extracted into the methanol-water (50/50, v/v) mixture that enabled extraction of only medium polar corticosteroids and not the non-polar components of matrices. This extract was cleaned-up and concentrated on polymeric Oasis HLB SPE cartridge. Separation involved isocratic solvent (methanol-acetate buffer, pH 5.4) and Ascentis Express Fused-Core type HLPC column; reduced the analysis time to 7.5 min, which is at least two times lower than time required for separation using conventional techniques. Other advantage of the developed method is the minimized ion suppression of LC-MS/MS analysis, which allowed detection of corticosteroids in sub μg/kg. Method was validated according to European Union (EU) Commission Decision 2002/657/EC. Measured parameters such as selectivity, linearity, recovery, within-laboratory reproducibility, decision limit, and detection capability satisfied the EU Directive. Ranges of mean recoveries and within-laboratory reproducibility were 81-100% and 8.0-20.5%, respectively. Decision limits were calculated in the range from 4.5 to 11.9 μg/kg for MRL compounds and varied from 0.1 to 0.2 μg/kg for banned substances. Limit of detections (LODs), calculated as three time signal-to-noise ratio, were in the range of 0.1-0.3 μg/kg. Copyright © 2010 Elsevier B.V. All rights reserved.
Yuan, Yue; Wang, Yan; Yang, Mingqi; Xu, Yicong; Chen, Weina; Zou, Xiaoli; Zheng, Bo
2018-05-01
A method of vortex-assisted dispersive liquid-liquid extraction coupled with gas chromatography and tandem mass spectrometry for the determination of nicotine and cotinine in urine was developed. Response surface methodology was applied to obtain the optimum extraction conditions. In this method, Plackett-Burman design was utilized to evaluate the impact of five selected factors on pretreatment procedure. Then, three main factors were optimized using a Box-Behnken design. The optimized method showed good linearities at 1-2000 μg/L with correlation coefficients of 0.9998 for nicotine and 0.9986 for cotinine. Recovery was 91.4-106 and 91.7-108% for nicotine and cotinine, respectively. The intraday relative standard derivations of determination were 1.47-4.06% for nicotine and 0.41-3.16% for cotinine, and interday relative standard derivations were 3.03-6.70% for nicotine and 1.64-6.38% for cotinine. The method detection limits for nicotine and cotinine were 0.33 and 0.34 μg/L, respectively. A total of 87 urine samples from smokers and nonsmokers were tested with the proposed method. Urinary nicotine and cotinine were 23.0-6.67 × 10 3 and 18.4-4.17 × 10 3 μg/(g·cr) for smokers and 1.31-286 and 1.39-131 μg/(g·cr) for nonsmokers, respectively. The method is sensitive, suitable and reliable for the determination of nicotine and cotinine in urine and meets the requirements for evaluating short-term tobacco exposure. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Chiesa, L; Panseri, S; Cannizzo, F T; Biolatti, B; Divari, S; Benevelli, R; Arioli, F; Pavlovic, R
2017-04-01
Under European legislation, the use of growth promoters is forbidden in food-producing livestock. The application of unofficial protocols with diverse combinations of veterinary drugs, administered in very low concentrations, hinders reliable detection and subsequent operative prevention. It was observed that nandrolone (anabolic steroid) and ractopamine (β-adrenergic agonist) are occasionally administered to animals, but little is known about their synergic action when they are administered together. Two specific analytical methods based on liquid chromatography-tandem mass spectrometry have been developed, both of which include hydrolysis of the corresponding conjugates. For the nandrolone method, solid-phase extraction was necessary for the complete elimination of the interferences, while employment of the Quantitation Enhanced Data-Dependent scan mode during MS acquisition of ractopamine enabled the utilization of simple liquid-liquid extraction. The nandrolone method was linear in the range of 0.5-25 ng/mL, while the ractopamine calibration curve was constructed from 0.5 to 1000 ng/mL. The corresponding coefficients of correlations were >0.9907. The lower limit of quantification for both methods was 0.5 ng/mL, followed by overall recoveries >81%. Precisions expressed as relative standard deviations were <17%, while matrix effects were minimal. Urine samples taken at the slaughterhouse from veal calves enrolled in an experimental treatment consisting of intramuscular administration of β-nandrolone-phenylpropionate accompanied with a ractopamine-enriched diet were analysed. Those methods might be useful for studying the elimination patterns of the administered compounds along with characterization of the main metabolic pathways. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Ma, Chao; Xiao, Sheng-yuan; Li, Zhen-guo; Wang, Wei; Du, Li-jun
2007-09-21
HPLC-DAD-MS was utilized to investigate the phytochemical constituents in ethanolic extract of Ananas comosus L. leaves (EEACL) responsible for antidiabetic, antihyperlipidemic and antioxidative effects. Eight phenylpropane diglycerides, together with two hydroxycinnamic acids, three hydroxycinnamoyl quinic acids, four phenylpropane monoglycerides, three flavones and six phenylpropanoid glycosides were detected, and their proposed structures were elucidated based on HPLC retention time, UV and MS profiles. Meanwhile, a new HPLC-DAD-MS method was established for the identification and characterization of phenylpropane diglycerides in natural plants.
Rapid analysis of abietanes in conifers.
Kersten, P J; Kopper, B J; Raffa, K F; Illman, B L
2006-12-01
Diterpene resin acids are major constituents of conifer oleoresin and play important roles in tree defense against insects and microbial pathogens. The tricyclic C-20 carboxylic acids are generally classified into two groups, the abietanes and the pimaranes. The abietanes have conjugated double bonds and exhibit characteristic UV spectra. Here, we report the analysis of abietanes by reversed-phase high-performance liquid chromatography using multiwavelength detection to optimize quantification of underivatized abietic, neoabietic, palustric, levopimaric, and dehydroabietic acids. The utility of the method is demonstrated with methanol extracts of white spruce (Picea glauca) phloem, and representative concentrations are reported.
Cunha, Rafael R; Chaves, Sandro C; Ribeiro, Michelle M A C; Torres, Lívia M F C; Muñoz, Rodrigo A A; Dos Santos, Wallans T P; Richter, Eduardo M
2015-05-01
Paracetamol, caffeine and ibuprofen are found in over-the-counter pharmaceutical formulations. In this work, we propose two new methods for simultaneous determination of paracetamol, caffeine and ibuprofen in pharmaceutical formulations. One method is based on high-performance liquid chromatography with diode-array detection and the other on capillary electrophoresis with capacitively coupled contactless conductivity detection. The separation by high-performance liquid chromatography with diode-array detection was achieved on a C18 column (250×4.6 mm(2), 5 μm) with a gradient mobile phase comprising 20-100% acetonitrile in 40 mmol L(-1) phosphate buffer pH 7.0. The separation by capillary electrophoresis with capacitively coupled contactless conductivity detection was achieved on a fused-silica capillary (40 cm length, 50 μm i.d.) using 10 mmol L(-1) 3,4-dimethoxycinnamate and 10 mmol L(-1) β-alanine with pH adjustment to 10.4 with lithium hydroxide as background electrolyte. The determination of all three pharmaceuticals was carried out in 9.6 min by liquid chromatography and in 2.2 min by capillary electrophoresis. Detection limits for caffeine, paracetamol and ibuprofen were 4.4, 0.7, and 3.4 μmol L(-1) by liquid chromatography and 39, 32, and 49 μmol L(-1) by capillary electrophoresis, respectively. Recovery values for spiked samples were between 92-107% for both proposed methods. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Wong, Tin-Long; An, Ya-Qi; Yan, Bing-Chao; Yue, Rui-Qi; Zhang, Tian-Bo; Ho, Hing-Man; Ren, Tian-Jing; Fung, Hau-Yee; Ma, Dik-Lung; Leung, Chung-Hang; Liu, Zhong-Liang; Pu, Jian-Xin; Han, Quan-Bin; Sun, Han-Dong
2016-06-05
YinHuang drop pill (YHDP) is a new preparation, derived from the traditional YinHuang (YH) decoction. Since drop pills are one of the newly developed forms of Chinese patent drugs, not much research has been done regarding the quality and efficacy. This study aims to establish a comprehensive quantitative analysis of the chemical profile of YHDP. ultra high-performance liquid chromatography quadrupole time of flight mass spectrometry (UHPLC-Q-TOF-MS/MS) was used to identify 34 non-sugar small molecules including 15 flavonoids, 9 phenolic acids, 5 saponins, 1 iridoid, and 4 iridoid glycosides in YHDP samples, and 26 of them were quantitatively determined. Sugar composition of YHDP in terms of fructose, glucose and sucrose was examined via a high performance liquid chromatography-evaporative light scattering detector on an amide column (HPLC-NH2P-ELSD). Macromolecules were examined by high performance gel permeation chromatography coupled with ELSD (HPGPC-ELSD). The content of the drop pill's skeleton component PEG-4000 was also quantified via ultra-high performance liquid chromatography coupled with charged aerosol detector (UHPLC-CAD). The results showed that up to 73% (w/w) of YHDP could be quantitatively determined. Small molecules accounted for approximately 5%, PEG-4000 represented 68%, while no sugars or macromolecules were found. Furthermore, YHDP showed no significant differences in terms of daily dosage, compared to YinHuang granules and YinHuang oral liquid; however, it has a higher small molecules content compared to YinHuang lozenge. Copyright © 2016 Elsevier B.V. All rights reserved.
Song, Huiying; Vanderheyden, Yoachim; Adams, Erwin; Desmet, Gert; Cabooter, Deirdre
2016-07-15
Diffusion plays an important role in all aspects of band broadening in chromatography. An accurate knowledge of molecular diffusion coefficients in different mobile phases is therefore crucial in fundamental column performance studies. Correlations available in literature, such as the Wilke-Chang equation, can provide good approximations of molecular diffusion under reversed-phase conditions. However, these correlations have been demonstrated to be less accurate for mobile phases containing a large percentage of acetonitrile, as is the case in hydrophilic interaction liquid chromatography. A database of experimentally measured molecular diffusion coefficients of some 45 polar and apolar compounds that are frequently used as test molecules under hydrophilic interaction liquid chromatography and reversed-phase conditions is therefore presented. Special attention is given to diffusion coefficients of polar compounds obtained in large percentages of acetonitrile (>90%). The effect of the buffer concentration (5-10mM ammonium acetate) on the obtained diffusion coefficients is investigated and is demonstrated to mainly influence the molecular diffusion of charged molecules. Diffusion coefficients are measured using the Taylor-Aris method and hence deduced from the peak broadening of a solute when flowing through a long open tube. The validity of the set-up employed for the measurement of the diffusion coefficients is demonstrated by ruling out the occurrence of longitudinal diffusion, secondary flow interactions and extra-column effects, while it is also shown that radial equilibration in the 15m long capillary is effective. Copyright © 2016 Elsevier B.V. All rights reserved.
Patel, Dhavalkumar Narendrabhai; Li, Lin; Kee, Chee-Leong; Ge, Xiaowei; Low, Min-Yong; Koh, Hwee-Ling
2014-01-01
The popularity of phosphodiesterase type 5 (PDE-5) enzyme inhibitors for the treatment of erectile dysfunction has led to the increase in prevalence of illicit sexual performance enhancement products. PDE-5 inhibitors, namely sildenafil, tadalafil and vardenafil, and their unapproved designer analogues are being increasingly used as adulterants in the herbal products and health supplements marketed for sexual performance enhancement. To date, more than 50 unapproved analogues of prescription PDE-5 inhibitors were found as adulterants in the literature. To avoid detection of such adulteration by standard screening protocols, the perpetrators of such illegal products are investing time and resources to synthesize exotic analogues and devise novel means for adulteration. A comprehensive review of conventional and advance analytical techniques to detect and characterize the adulterants is presented. The rapid identification and structural elucidation of unknown analogues as adulterants is greatly enhanced by the wide myriad of analytical techniques employed, including high performance liquid chromatography (HPLC), gas chromatography-mass spectrometry (GC-MS), liquid chromatography mass-spectrometry (LC-MS), nuclear magnetic resonance (NMR) spectroscopy, vibrational spectroscopy, liquid chromatography-Fourier transform ion cyclotron resonance-mass spectrometry (LC-FT-ICR-MS), liquid chromatograph-hybrid triple quadrupole linear ion trap mass spectrometer with information dependent acquisition, ultra high performance liquid chromatography-time of flight-mass spectrometry (UHPLC-TOF-MS), ion mobility spectroscopy (IMS) and immunoassay methods. The many challenges in detecting and characterizing such adulterants, and the need for concerted effort to curb adulteration in order to safe guard public safety and interest are discussed. Copyright © 2013 Elsevier B.V. All rights reserved.
Touriño, Sonia; Fuguet, Elisabet; Jáuregui, Olga; Saura-Calixto, Fulgencio; Cascante, Marta; Torres, Josep Lluís
2008-11-01
Grape antioxidant dietary fiber (GADF) is a dietary supplement that combines the benefits of both fiber and antioxidants that help prevent cancer and cardiovascular diseases. The antioxidant polyphenolic components in GADF probably help prevent cancer in the digestive tract, where they are bioavailable. Mass spectrometry coupled to liquid chromatography is a powerful tool for the analysis of complex plant derivatives such as GADF. We use a combination of MS techniques, namely liquid chromatography/electrospray ionization time-of-flight mass spectrometry (LC/ESI-TOF-MS) and liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) on a triple quadrupole, for the identification of the polyphenolic constituents of the soluble fraction of GADF. First, we separated the mixture into four fractions which were tested for phenolic constituents using the TOF system in the full scan mode. The high sensitivity and resolution of the TOF detector over the triple quadrupole facilitate the preliminary characterization of the fractions. Then we used LC/ESI-MS/MS to identify the individual phenols through MS/MS experiments (product ion scan, neutral loss scan, precursor ion scan). Finally, most of the identities were unequivocally confirmed by accurate mass measurements on the TOF spectrometer. LC/ESI-TOF-MS combined with MS/MS correctly identifies the bioactive polyphenolic components from the soluble fraction of GADF. High-resolution TOF-MS is particularly useful for identifying the structure of compounds with the same LC/ESI-MS/MS fragmentation patterns.
Sheng, Ning; Zheng, Hao; Xiao, Yao; Wang, Zhe; Li, Menglin; Zhang, Jinlan
2017-09-29
Chemical profile for Chinese medicine formulas composed of several herbs is always a challenge due to a big array of small molecules with high chemical diversity so much as isomers. The present paper develops a feasible strategy to characterize and identify complex chemical constituents of a four-herb traditional Chinese medicine formula, Denzhan Shenmai (DZSM) by integrating comprehensive two-dimensional liquid chromatography coupled with quadrupole time-of-flight mass spectrometry (LC×LC-qTOF-MS) with multiple heart-cutting two-dimensional liquid chromatography coupled with quadrupole time-of-flight mass spectrometry (MHC-qTOF-MS). DZSM was separated by C8×C18 HPLC column system for comprehensive two-dimensional liquid chromatography system and 283 compounds most of which belonged to phenolic acid, flavonoid, saponin and lignan families were characterized and identified within 75min. Some isomers and compounds at low level were analyzed on C8×Chiral HPLC column system for multiple heart-cutting two-dimensional liquid chromatography system with 1D and 2D optimized gradient elution program. These 1D cutting fractions were successively separated on 2D chiral chromatographic column under extended the 2D gradient elution time from 30s to 5.0min. 12 pairs of isomer compounds were separated with good resolution. The combination of LC×LC and MHC system provides a powerful technique for global chemical profiling of DZSM and provided feasible strategy for other complex systems. Copyright © 2017 Elsevier B.V. All rights reserved.
Yan, Xia; Wang, Li-Juan; Wu, Zhen; Wu, Yun-Long; Liu, Xiu-Xiu; Chang, Fang-Rong; Fang, Mei-Juan; Qiu, Ying-Kun
2016-10-15
Microbial metabolites represent an important source of bioactive natural products, but always exhibit diverse of chemical structures or complicated chemical composition with low active ingredients content. Traditional separation methods rely mainly on off-line combination of open-column chromatography and preparative high performance liquid chromatography (HPLC). However, the multi-step and prolonged separation procedure might lead to exposure to oxygen and structural transformation of metabolites. In the present work, a new two-dimensional separation workflow for fast isolation and analysis of microbial metabolites from Chaetomium globosum SNSHI-5, a cytotoxic fungus derived from extreme environment. The advantage of this analytical comprehensive two-dimensional liquid chromatography (2D-LC) lies on its ability to analyze the composition of the metabolites, and to optimize the separation conditions for the preparative 2D-LC. Furthermore, gram scale preparative 2D-LC separation of the crude fungus extract could be performed on a medium-pressure liquid chromatograph×preparative high-performance liquid chromatography system, under the optimized condition. Interestingly, 12 cytochalasan derivatives, including two new compounds named cytoglobosin Ab (3) and isochaetoglobosin Db (8), were successfully obtained with high purity in a short period of time. The structures of the isolated metabolites were comprehensively characterized by HR ESI-MS and NMR. To be highlighted, this is the first report on the combination of analytical and preparative 2D-LC for the separation of microbial metabolites. The new workflow exhibited apparent advantages in separation efficiency and sample treatment capacity compared with conventional methods. Copyright © 2016 Elsevier B.V. All rights reserved.
Chang, Lin; Shao, Qian; Xi, Xingjun; Chu, Qiao; Wei, Yun
2017-02-01
Aqueous two-phase flotation followed by preparative high-performance liquid chromatography was used to separate four flavonol glycosides from Solanum rostratum Dunal. In the aqueous two-phase flotation section, the effects of sublation solvent, solution pH, (NH 4 ) 2 SO 4 concentration in aqueous solution, cosolvent, N 2 flow rate, flotation time, and volumes of the polyethylene glycol phase on the recovery were investigated in detail, and the optimal conditions were selected: 50 wt% polyethylene glycol 1000 ethanol solvent as the flotation solvent, pH 4, 350 g/L of (NH 4 ) 2 SO 4 concentration in aqueous phase, 40 mL/min of N 2 flow rate, 30 min of flotation time, 10.0 mL of flotation solvent volume, and two times. After aqueous two-phase flotation concentration, the flotation products were purified by preparative high-performance liquid chromatography. The purities of the final products A and B were 98.1 and 99.0%. Product B was the mixture of three compounds based on the analysis of high-performance liquid chromatography at the temperature of 10°C, while product A was hyperoside after the identification by nuclear magnetic resonance. Astragalin, 3'-O-methylquercetin 3-O-β-d-galactopyranoside, and 3'-O-methylquercetin 3-O-β-d-glucopyranoside were obtained with the purity of 93.8, 97.1, and 99.2%, respectively, after the further separation of product B using preparative high-performance liquid chromatography. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Michel, Thomas; Destandau, Emilie; Elfakir, Claire
2011-09-09
Centrifugal Partition Chromatography (CPC), a liquid-liquid preparative chromatography using two immiscible solvent systems, benefits from numerous advantages for the separation or purification of synthetic or natural products. This study presents the on-line hyphenation of CPC-Evaporative Light Scattering Detector (CPC-ELSD) with High Performance Liquid Chromatography-UV (HPLC-UV) for the fractionation of flavonols from a solvent-free microwave extract of sea buckthorn (Hippophaë rhamnoides L., Elaeagnaceae) berries. An Arizona G system was used for the fractionation of flavonoids by CPC and a fused core Halo C18 column allowed the on-line analyses of collected fractions by HPLC. The on-line CPC/HPLC procedure allowed the simultaneous fractionation step at preparative scale combined with the HPLC analyses which provide direct fingerprint of collected fractions. Thus the crude extract was simplified and immediate information on the composition of fractions could be obtained. Furthermore, this methodology reduced the time of post-fractionation steps and facilitated identification of main molecules by Mass Spectrometry (MS). Rutin, isorhamnetin-3-O-rutinoside, isorhamnetin-3-O-glucoside, quercetin-3-O-glucoside, isorhamnetin-rhamnoside, quercetin and isorhamnetin were identified. CPC-ELSD/HPLC-UV could be considered as a high-throughput technique for the guided fractionation of bioactive natural products from complex crude extracts. Copyright © 2011 Elsevier B.V. All rights reserved.
Poch, G K; Klette, K L; Anderson, C
2000-04-01
This paper compares the potential forensic application of two sensitive and rapid procedures (liquid chromatography-mass spectrometry and liquid chromatography-ion trap mass spectrometry) for the detection and quantitation of 2-oxo-3-hydroxy lysergic acid diethylamide (O-H-LSD) a major LSD metabolite. O-H-LSD calibration curves for both procedures were linear over the concentration range 0-8,000 pg/mL with correlation coefficients (r2) greater than 0.99. The observed limit of detection (LOD) and limit of quantitation (LOQ) for O-H-LSD in both procedures was 400 pg/mL. Sixty-eight human urine specimens that had previously been found to contain LSD by gas chromatography-mass spectrometry were reanalyzed by both procedures for LSD and O-H-LSD. These specimens contained a mean concentration of O-H-LSD approximately 16 times higher than the LSD concentration. Because both LC methods produce similar results, either procedure can be readily adapted to O-H-LSD analysis for use in high-volume drug-testing laboratories. In addition, the possibility of significantly increasing the LSD detection time window by targeting this major LSD metabolite for analysis may influence other drug-free workplace programs to test for LSD.
Gika, Helen G; Theodoridis, Georgios; Extance, Jon; Edge, Anthony M; Wilson, Ian D
2008-08-15
The applicability and potential of using elevated temperatures and sub 2-microm porous particles in chromatography for metabonomics/metabolomics was investigated using, for the first time, solvent temperatures higher than the boiling point of water (up to 180 degrees C) and thermal gradients to reduce the use of organic solvents. Ultra performance liquid chromatography, combined with mass spectrometry, was investigated for the global metabolite profiling of the plasma and urine of normal and Zucker (fa/fa) obese rats (a well established disease animal model). "Isobaric" high temperature chromatography, where the temperature and flow rate follow a gradient program, was developed and evaluated against a conventional organic solvent gradient. LC-MS data were first examined by established chromatographic criteria in order to evaluate the chromatographic performance and next were treated by special peak picking algorithms to allow the application of multivariate statistics. These studies showed that, for urine (but not plasma), chromatography at elevated temperatures provided better results than conventional reversed-phase LC with higher peak capacity and better peak asymmetry. From a systems biology point of view, better group clustering and separation was obtained with a larger number of variables of high importance when using high temperature-ultra performance liquid chromatography (HT-UPLC) compared to conventional solvent gradients.
Wang, Lu; Liu, Shu; Zhang, Xueju; Xing, Junpeng; Liu, Zhiqiang; Song, Fengrui
2016-06-24
In this paper, an analysis strategy integrating macroporous resin (AB-8) column chromatography and high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) combined with ion mobility spectrometry (IMS) was proposed and applied for identification and structural characterization of compounds from the fruits of Gardenia jasminoides. The extracts of G. jasminoides were separated by AB-8 resin column chromatography combined with reversed phase liquid chromatography (C18 column) and detected by electrospray ionization tandem mass spectrometry. Additionally, ion mobility spectrometry (IMS) was employed as a supplementary separation technique to discover previously undetected isomers from the fruits of G. jasminoides. A total of 71 compounds, including iridoids, flavonoids, triterpenes, monoterpenoids, carotenoids and phenolic acids were identified by the characteristic high resolution mass spectrometry and the ESI-MS/MS fragmentations. In conclusion, the IMS-MS technique achieved the separation of isomers in crocin-3 and crocin-4 according to their acquired mobility drift times differing from classical analysis by mass spectrometry. The proposed strategy can be used as a highly sensitive and efficient procedure for identification and separation isomeric components in extracts of herbal medicines. Copyright © 2016 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Schaber, Peter M.
1985-01-01
Background information, procedures used, and typical results obtained are provided for an experiment involving the separation of chlorophyll a and chlorophyll b from their diastereomers. Reasons why the experiment can be easily integrated into most laboratory curricula where high-performance liquid chromatography capabilities exist are given. (JN)
Hosoi, Shinzo; Shimizu, Eri; Arimori, Kazuhiko; Okumura, Manabu; Hidaka, Muneaki; Yamada, Mitsuko; Sakushima, Akiyo
2008-07-01
In this study, we analyzed the CYP3A inhibitory components of star fruit Averrhoa carambola L., using liquid chromatography-mass spectrometry (LC-MS). The stereoisomer of procyanidin B1 and B2 and/or the trimer consisting of catechin and/or epicatechin were suggested to be potent inhibitory components.
The purpose of the research presented in this paper is two-fold: (1) to demonstrate the 4 coupling of two state-of-the-art techniques: a time-weighted polar organic integrative sampler (POCIS) and micro-liquid chromatography-electrospray/ion trap mass spectrometry (u-LC-6 ES/ITMS...
USDA-ARS?s Scientific Manuscript database
A novel, rapid and sensitive Ultra Performance Liquid-Chromatography tandem Mass-Spectrometry (UPLC-MS/MS) method for the simultaneous determination of several B-vitamins in human milk was developed. Resolution by retention time or multiple reaction monitoring (MRM) for thiamin, riboflavin, flavin a...
USDA-ARS?s Scientific Manuscript database
Cultures of Fusarium sporotrichioides were extracted and subjected to evaluation by high performance liquid chromatography – tandem mass spectrometry (LC-MS/MS). Along with the expected T-2 and HT-2 toxins, compounds 162 m/z higher than the toxins were observed. Fragmentation behavior of the larger ...
Review of Peak Detection Algorithms in Liquid-Chromatography-Mass Spectrometry
Zhang, Jianqiu; Gonzalez, Elias; Hestilow, Travis; Haskins, William; Huang, Yufei
2009-01-01
In this review, we will discuss peak detection in Liquid-Chromatography-Mass Spectrometry (LC/MS) from a signal processing perspective. A brief introduction to LC/MS is followed by a description of the major processing steps in LC/MS. Specifically, the problem of peak detection is formulated and various peak detection algorithms are described and compared. PMID:20190954
Production of Reactive Oxygen Species by Polyhalogenated Cyclic Hydrocarbons (PCH)
1991-07-22
dry ice in metabolism cages. One ml aliquots of urine were derivatized with 2,4- dinitrophenylhydrazine , and extracted with pentane. The hydrazones of...U.S.A. Key Words: formaldehyde; acetaldehyde; malondialdehyde; acetone; high pressure liquid chromatography; 2,4- dinitrophenylhydrazine ; gas... dinitrophenylhydrazine , and extracted with pentane. The hydrazones of the four lipid metabolic products were quantitated by high pressure liquid chromatography
The cyclic heptapeptide microcystin toxins produced by a strain of Microcystis aeruginosa that has not been investigated previously were separated by liquid chromatography and identified by high-accuracy m/z measurements of their [M + H]+ ions and the fragment i...
USDA-ARS?s Scientific Manuscript database
A liquid chromatography-mass spectrometry method was developed for the analysis of the indolizidine alkaloid swainsonine and its N-oxide. The method is based on a one step solvent partitioning extraction procedure followed by trimethylsilylation of the dried extract and subsequent detection and qua...
Patricia L. Faulkner; Michele M. Schoeneberger; Kim H. Ludovici
1993-01-01
Foliar tissue was collected from a field study designed to test impacts of atmospheric pollutants on loblolIy pine (Pinus taeda L.) seedlings. Standard enzymatic (ENZ) and high performance liquid chromatography (HPLC) methods were used to analyze the tissue for soluble sugars. A comparison of the methods revealed no significant diffennces in accuracy...
1988-07-15
solvents were used. For high performance liquid chromatographic studies, the DNA bases thymine, adenine, cytocine, uracil, and guanine (Aldrich...this experiment. The DNA bases guanine, adenine, cytocine, uracil, and thymine were detected for a gradient elution of a mixture of the bases in a
USDA-ARS?s Scientific Manuscript database
In the field of food contaminant analysis, the most significant development of recent years has been the integration of ultra-high pressure liquid chromatography (UHPLC), coupled to tandem quadrupole mass spectrometry (MS/MS), into analytical applications. In this review, we describe the emergence o...
Method 544 is an accurate and precise analytical method to determine six microcystins (including MC-LR) and nodularin in drinking water using solid phase extraction and liquid chromatography tandem mass spectrometry (SPE-LC/MS/MS). The advantage of this SPE-LC/MS/MS is its sensi...
Fragrance materials such as synthetic musks in aqueous samples, are normally determined by gas chromatography/mass spectrometry in the selected ion monitoring (SIM) mode to provide maximum sensitivity after liquid-liquid extraction of I -L samples. Full-scan mass spectra are requ...
Ahrens, Brian D; Kucherova, Yulia; Butch, Anthony W
2016-01-01
Sports drug testing laboratories are required to detect several classes of compounds that are prohibited at all times, which include anabolic agents, peptide hormones, growth factors, beta-2 agonists, hormones and metabolic modulators, and diuretics/masking agents. Other classes of compounds such as stimulants, narcotics, cannabinoids, and glucocorticoids are also prohibited, but only when an athlete is in competition. A single class of compounds can contain a large number of prohibited substances and all of the compounds should be detected by the testing procedure. Since there are almost 70 stimulants on the prohibited list it can be a challenge to develop a single screening method that will optimally detect all the compounds. We describe a combined liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS) testing method for detection of all the stimulants and narcotics on the World Anti-Doping Agency prohibited list. Urine for LC-MS/MS testing does not require sample pretreatment and is a direct dilute and shoot method. Urine samples for the GC-MS method require a liquid-liquid extraction followed by derivatization with trifluoroacetic anhydride.
Gevaert, Bert; D'Hondt, Matthias; Bracke, Nathalie; Yao, Han; Wynendaele, Evelien; Vissers, Johannes Petrus Cornelis; De Cecco, Martin; Claereboudt, Jan; De Spiegeleer, Bart
2015-09-01
Cerebrolysin, a parenteral peptide preparation produced by controlled digestion of porcine brain proteins, is an approved nootropic medicine in some countries. However, it is also easily and globally available on the Internet. Nevertheless, until now, its exact chemical composition was unknown. Using high performance liquid chromatography (HPLC) coupled to ion trap and ultra high performance liquid chromatography (UHPLC) coupled to quadrupole-ion mobility-time-of-flight mass spectrometry (Q-IM-TOF MS), combined with UniProt pig protein database search and PEAKS de novo sequencing, we identified 638 unique peptides in an Internet-obtained Cerebrolysin sample. The main components in this sample originate from tubulin alpha- and beta-chain, actin, and myelin basic protein. No fragments of known neurotrophic factors like glial cell-derived neurotrophic factor (GDNF), neurotrophin nerve growth factor (NGF), brain-derived neurotrophic factor (BDNF), and ciliary neurotrophic factor (CNTF) were found, suggesting that the activities reported in the literature are likely the result of new, hitherto unknown cryptic peptides with nootropic properties. Copyright © 2015 John Wiley & Sons, Ltd.
Pirulli, D; Giordano, M; Lessi, M; Spanò, A; Puzzer, D; Zezlina, S; Boniotto, M; Crovella, S; Florian, F; Marangella, M; Momigliano-Richiardi, P; Savoldi, S; Amoroso, A
2001-06-01
Primary hyperoxaluria type 1 is an autosomal recessive disorder of glyoxylate metabolism, caused by a deficiency of alanine:glyoxylate aminotransferase, which is encoded by a single copy gene (AGXT. The aim of this research was to standardize denaturing high-performance liquid chromatography, a new, sensitive, relatively inexpensive, and automated technique, for the detection of AGXT mutation. Denaturing high-performance liquid chromatography was used to analyze in blind the AGXT gene in 20 unrelated Italian patients with primary hyperoxaluria type I previously studied by other standard methods (single-strand conformation polymorphism analysis and direct sequencing) and 50 controls. Denaturing high-performance liquid chromatography allowed us to identify 13 mutations and the polymorphism at position 154 in exon I of the AGXT gene. Hence the method is more sensitive and less time consuming than single-strand conformation polymorphism analysis for the detection of AGXT mutations, thus representing a useful and reliable tool for detecting the mutations responsible for primary hyperoxaluria type 1. The new technology could also be helpful in the search for healthy carriers of AGXT mutations amongst family members and their partners, and for screening of AGXT polymorphisms in patients with nephrolithiasis and healthy populations.
Jin, Hongli; Liu, Yanfang; Guo, Zhimou; Wang, Jixia; Zhang, Xiuli; Wang, Chaoran; Liang, Xinmiao
2016-10-25
Traditional Chinese Medicine (TCM) is an ancient medical practice which has been used to prevent and cure diseases for thousands of years. TCMs are frequently multi-component systems with mainly unidentified constituents. The study of the chemical compositions of TCMs remains a hotspot of research. Different strategies have been developed to manage the significant complexity of TCMs, in an attempt to determine their constituents. Reversed-phase liquid chromatography (RPLC) is still the method of choice for the separation of TCMs, but has many problems related to limited selectivity. Recently, enormous efforts have been concentrated on the development of efficient liquid chromatography (LC) methods for TCMs, based on selective stationary phases. This can improve the resolution and peak capacity considerably. In addition, high-efficiency stationary phases have been applied in the analysis of TCMs since the invention of ultra high-performance liquid chromatography (UHPLC). This review describes the advances in LC methods in TCM research from 2010 to date, and focuses on novel stationary phases. Their potential in the separation of TCMs using relevant applications is also demonstrated. Copyright © 2016 Elsevier B.V. All rights reserved.
Turak, Fatma; Güzel, Remziye; Dinç, Erdal
2017-04-01
A new reversed-phase ultraperformance liquid chromatography method with a photodiode array detector was developed for the quantification of ascorbic acid (AA) and caffeine (CAF) in 11 different commercial drinks consisting of one energy drink and 10 ice tea drinks. Separation of the analyzed AA and CAF with an internal standard, caffeic acid, was performed on a Waters BEH C 18 column (100 mm × 2.1 mm, 1.7 μm i.d.), using a mobile phase consisting of acetonitrile and 0.2M H 3 PO 4 (11:89, v/v) with a flow rate of 0.25 mL/min and an injection volume of 1.0 μL. Calibration graphs for AA and CAF were computed from the peak area ratio of AA/internal standard and CAF/internal standard detected at 244.0 nm and 273.6 nm, respectively. The developed reversed-phase ultraperformance liquid chromatography method was validated by analyzing standard addition samples. The proposed reversed-phase ultraperformance liquid chromatography method gave us successful results for the quantitative analysis of commercial drinks containing AA and CAF substances. Copyright © 2016. Published by Elsevier B.V.
Li, Fangbing; Wang, Hui; Xin, Huaxia; Cai, Jianfeng; Fu, Qing; Jin, Yu
2016-12-01
Purified standards of xylooligosaccharides (XOSs) (DP2-6) were first prepared from a mixture of XOSs using solid phase extraction (SPE), followed by semi-preparative liquid chromatography both under hydrophilic interaction liquid chromatography (HILIC) modes. Then, an accurate quantitative analysis method based on hydrophilic interaction liquid chromatography-evaporative light scattering detection (HILIC-ELSD) was developed and validated for simultaneous determination of xylose (X1), xylobiose (X2), xylotriose (X3), xylotetraose (X4), xylopentaose (X5), and xylohexaose (X6). This developed HILIC-ELSD method was applied to the comparison of different hydrolysis methods for xylans and assessment of XOSs contents from different agricultural wastes. The result indicated that enzymatic hydrolysis was preferable with fewer by-products and high XOSs yield. The XOSs yield (48.40%) from sugarcane bagasse xylan was the highest, showing conversions of 11.21g X2, 12.75g X3, 4.54g X4, 13.31g X5, and 6.78g X6 from 100g xylan. Copyright © 2016 Elsevier Ltd. All rights reserved.
GLC analysis of base composition of RNA and DNA hydrolysates
NASA Technical Reports Server (NTRS)
Lakings, D. B.; Gehreke, C. W.
1971-01-01
Various methods used for the analysis of the base composition of RNA and DNA hydrolysates are presented. The methods discussed are: (1) ion-exchange chromatography, (2) paper chromatography, (3) paper electrophoresis, (4) thin layer chromatography, (5) paper chromatography and time of flight mass spectrometry, and (6) gas-liquid chromatography. The equipment required and the conditions for obtaining the best results with each method are described.
Acrylamide: formation, occurrence in food products, detection methods, and legislation.
Arvanitoyannis, Ioannis S; Dionisopoulou, Niki
2014-01-01
This review aims at summarizing the most recent updates in the field of acrylamide (AA) formation (mechanism, conditions) and the determination of AA in a number of foods (fried or baked potatoes, chips, coffee, bread, etc). The methods applied for AA detection [Capillary Electrophoresis-Mass Spectrometry (CE-MS), Liquid Chromatography-Mass Spectrometry (LC-MS), Non-Aqueous Capillary Electrophoresis (NACE), High Performance Liquid Chromatography-Mass Spectrometry (HPLC-MS), Pressurized Fluid Extraction (PFE), Matrix Solid-Phase Dispersion (MSPD), Gas Chromatography-Mass Spectrometry (GC-MS), Solid-Phase MicroExtraction-Gas Chromatography (SPME-GC), Enzyme Linked Immunosorbent Assay (ELISA), and MicroEmulsion ElectroKinetic Chromatography (MEEKC) are presented and commented. Several informative figures and tables are included to show the effect of conditions (temperature, time) on the AA formation. A section is also included related to AA legislation in EU and US.
Silica, hybrid silica, hydride silica and non-silica stationary phases for liquid chromatography.
Borges, Endler M
2015-04-01
Free silanols on the surface of silica are the "villains", which are responsible for detrimental interactions of those compounds and the stationary phase (i.e., bad peak shape, low efficiency) as well as low thermal and chemical stability. For these reasons, we began this review describing new silica and hybrid silica stationary phases, which have reduced and/or shielded silanols. At present, in liquid chromatography for the majority of analyses, reversed-phase liquid chromatography is the separation mode of choice. However, the needs for increased selectivity and increased retention of hydrophilic bases have substantially increased the interest in hydrophilic interaction chromatography (HILIC). Therefore, stationary phases and this mode of separation are discussed. Then, non-silica stationary phases (i.e., zirconium oxide, titanium oxide, alumina and porous graphitized carbon), which afford increased thermal and chemical stability and also selectivity different from those obtained with silica and hybrid silica, are discussed. In addition, the use of these materials in HILIC is also reviewed. © Crown copyright 2014.
Yao, Chang-liang; Yang, Wen-zhi; Wu, Wan-Yyng; Da, Juan; Hou, Jin-jun; Zhang, Jing-xian; Zhang, Yan-hai; Jin, Yan; Yang, Min; Jiang, Bao-hong; Liu, Xuan; Guo, De-an
2015-07-10
Current China Pharmacopoeia (ChP) standards employ diversified and case-dependent assay methods to evaluate the quality of different Chinese patent medicines (CPMs) that contain Panax notoginseng as the monarch drug. These conventional, HPLC-based approaches, utilizing a complex sample preparation procedure, can easily result in low analytical efficiency and possible component loss. Here, a "monomethod-heterotrait matrix" (MHM) strategy is proposed, that is, developing a universal multi heart-cutting two-dimensional liquid chromatography (MHC-2D-LC) approach that facilitates the simultaneous quantitation of five P. notoginseng saponins (noto-R1, Re, Rg1, Rb1, and Rd) in eight different CPMs. The MHC-2D-LC system was constructed on a dual-gradient liquid chromatography instrument equipped with a Poroshell SB C18 column and a Zorbax SB-Aq column for respective (1)D and (2)D separation. Method validation was performed in terms of specificity, linearity (r(2) and F-test), intra-/inter-day precision (0.4-7.9%), stability (1.2-3.9%), and recovery (90.2-108.7%), and the LODs and LOQs (loaded masses) of the five analytes varied between 4.0-11.0ng and 6.0-33.0ng, respectively. The validated MHC-2D-LC approach was subsequently applied to quantify the five saponins in thirty batches of different CPMs. The method demonstrated superiority over the current ChP assay methods in respect of specificity (avoiding co-elution), resolution (Rs>1.5), sample preparation (easy-to-implement ultrasonic extraction without repeated re-extraction), and transfer rate (minimum component loss). This is the first application of an MHC-2D-LC method for the quantitative assessment of the constituents of CPMs. The MHM approach represents a new, strategically significant methodology for the quality control of CPMs that involve complex chemical matrix. Copyright © 2015 Elsevier B.V. All rights reserved.
Arning, Erland; Bottiglieri, Teodoro
2016-01-01
We describe a simple stable isotope dilution method for accurate and precise measurement of γ-aminobutyric acid (GABA), a major inhibitory neurotransmitter in human cerebrospinal fluid (CSF) as a clinical diagnostic test. Determination of GABA in CSF (50 μL) was performed utilizing high performance liquid chromatography coupled with electrospray positive ionization tandem mass spectrometry (HPLC-ESI-MS/MS). Analysis of free and total GABA requires two individual sample preparations and mass spectrometry analyses. Free GABA in CSF is determined by a 1:2 dilution with internal standard (GABA-D2) and injected directly onto the HPLC-ESI-MS/MS system. Determination of total GABA in CSF requires additional sample preparation in order to hydrolyze all the bound GABA in the sample to the free form. This requires hydrolyzing the sample by boiling in acidic conditions (hydrochloric acid) for 4 h. The sample is then further diluted 1:10 with a 90 % acetonitrile/0.1 % formic acid solution and injected into the HPLC-ESI-MS/MS system. Each assay is quantified using a five-point standard curve and is linear from 6 nM to 1000 nM and 0.63 μM to 80 μM for free and total GABA, respectively.
Sonophotocatalytic mineralization of Norflurazon in aqueous environment.
Sathishkumar, Panneerselvam; Mangalaraja, Ramalinga Viswanathan; Rozas, Oscar; Vergara, Carola; Mansilla, Héctor D; Gracia-Pinilla, M A; Anandan, Sambandam
2016-03-01
Norflurazon (4-chloro-5-(methylamino)-2-[3-(trifluoromethyl)phenyl]pyridazin-3(2H)-one; C12H9ClF3N3O) is an excellent weed controlling agent being practiced in the agricultural lands. The excessive addition or the undissolved Norflurazon (maximum solubility 28 mg/L at 25 °C) enters into the aquatic environment and causes the adverse effects associated with its high concentration. To avoid the perilous effects, visible light assisted photocatalysis set-up coupled with the 42 kHz ultrasound producing bath type sonicator is used to completely mineralize the Norflurazon. TiO2, ZnO and gold loaded zinc oxide nanocatalysts were utilized to study the mineralization of Norflurazon. Au-ZnO shows the greater efficiency for the sonophotocatalytic removal of Norflurazon among the various nanocatalysts employed to study the mineralization. The order of Norflurazon mineralization was sonophotocatalysis > sonocatalysis > photocatalysis. The additive effect was achieved for the sonophotocatalytic degradation. The high performance liquid chromatography (HPLC) and liquid chromatography-mass spectrometric (LCMS) analyses were employed to identify the various intermediates produced during the mineralization. The identification of four pseudo molecular ions and various intermediates using the LCMS analysis evidently suggests the sonophotocatalytic degradation was preceded in various decay pathways. A suitable mechanism has been proposed for the sonophotocatalytic mineralization of Norflurazon. Copyright © 2015 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dietz, M. L.
1998-11-30
The determination of low levels of radionuclides in environmental and biological samples is often hampered by the complex and variable nature of the samples. One approach to circumventing this problem is to incorporate into the analytical scheme a separation and preconcentration step by which the species of interest can be isolated from the major constituents of the sample. Extraction chromatography (EXC), a form of liquid chromatography in which the stationary phase comprises an extractant or a solution of an extractant in an appropriate diluent coated onto an inert support, provides a simple and efficient means of performing a wide varietymore » of metal ion separations. Recent advances in extractant design, in particular the development of extractants capable of metal ion recognition or of strong complex formation even in acidic media, have substantially improved the utility of the method. For the preconcentration of actinides, for example, an EXC resin consisting of a liquid diphosphonic acid supported on a polymeric substrate has been shown to exhibit extraordinarily strong retention of these elements from acidic chloride media. This resin, together with other related materials, can provide the basis of a number of efficient and flexible schemes for the separation and preconcentration of radionuclides form a variety of samples for subsequent determination.« less
Wang, Liqun; Cardenas, Roberto Bravo; Watson, Clifford
2017-09-08
CDC's Division of Laboratory Sciences developed and validated a new method for the simultaneous detection and measurement of 11 sugars, alditols and humectants in tobacco products. The method uses isotope dilution ultra high performance liquid chromatography coupled with tandem mass spectrometry (UHPLC-MS/MS) and has demonstrated high sensitivity, selectivity, throughput and accuracy, with recoveries ranging from 90% to 113%, limits of detection ranging from 0.0002 to 0.0045μg/mL and coefficients of variation (CV%) ranging from 1.4 to 14%. Calibration curves for all analytes were linear with linearity R 2 values greater than 0.995. Quantification of tobacco components is necessary to characterize tobacco product components and their potential effects on consumer appeal, smoke chemistry and toxicology, and to potentially help distinguish tobacco product categories. The researchers analyzed a variety of tobacco products (e.g., cigarettes, little cigars, cigarillos) using the new method and documented differences in the abundance of selected analytes among product categories. Specifically, differences were detected in levels of selected sugars found in little cigars and cigarettes, which could help address appeal potential and have utility when product category is unknown, unclear, or miscategorized. Copyright © 2017. Published by Elsevier B.V.
Sun, Shi-Hao; Xie, Jian-Ping; Xie, Fu-Wei; Zong, Yong-Li
2008-02-01
A method coupling needle-based derivatization headspace liquid-phase microextraction with gas chromatography-mass spectrometry (HS-LPME/GC-MS) was developed to determine volatile organic acids in tobacco. The mixture of N,O-bis(trimethylsilyl)trifluoroacetamide and decane was utilized as the solvent for HS-LPME, resulting that extraction and derivatization were simultaneously completed in one step. The solvent served two purposes. First, it pre-concentrated volatile organic acids in the headspace of tobacco sample. Second, the volatile organic acids extracted were derivatized to form silyl derivatives in the drop. The main parameters affecting needle-based derivatization HS-LPME procedure such as extraction and derivatization reagent, microdrop volume, extraction and derivatization time, and preheating temperature and preheating time were optimized. The standard addition approach was essential to obtain accurate measurements by minimizing matrix effects. Good linearity (R(2)> or =0.9804) and good repeatability (RSDs< or =15.3%, n=5) for 16 analytes in spiked standard analytes sample were achieved. The method has the additional advantages that at the same time it is simple, fast, effective, sensitive, selective, and provides an overall profile of volatile organic acids in the oriental tobacco. This paper does offer an alternative approach to determine volatile organic acids in tobacco.
DOE Office of Scientific and Technical Information (OSTI.GOV)
LaFreniere, K.E.
A direct injection nebulizer (DIN) was designed, developed and evaluated to determine its potential utilization as an effective interface for flow injection analysis (FIA) and high performance liquid chromatography (HPLC) coupled with inductively coupled plasma-atomic emission spectroscopic detection. The analytical figures of merit for the DIN when used as an interface for FIA-ICP-AES were found to be comparable to or better than those obtained with conventional pneumatic nebulization in terms of limits of detection (LODs), reproducibility, linearity, and interelement effects. In the HPLC mode, the LODDs were found to be comparable to those obtained by continuous-flow sample introduction into themore » ICP, or inferior by up to only a factor of four. Stable plasma operation was maintained for the DIN sample introduction of a variety of pure organic solvents, including acetonitrile, methanol, methyl-isobutylketone, and pyridine. The HPLC-DIN-ICP-AES facility was specifically applied for the speciation of inorganic and organo-metallic species contained in synthetic mixtures, vanilla extracts and a variety of energy-related materials, such as shale oil process water, coal extracts, shale oil, crude oil, and an SRC II. Suggestions for future research are also considered.« less
In Vitro Metabolism of 3,4-Methylenedioxymethamphetamine in Human Hepatocytes
Ramaley, Corinne; Leonard, Susan C.; Miller, Jeffrey D.; Wilson, Denita Takesha-Mashia; Chang, Sai Y.; Chen, Qingyu; Li, Feng; Du, Chengan
2014-01-01
Users of the illicit drug, 3,4-methylenedioxymethamphetamine (MDMA), show signs of neurotoxicity. However, the precise mechanism of neurotoxicity caused by use of MDMA has not yet been elucidated. Synthetic glutathione (GSH) conjugates of MDMA are transported into the brain by the GSH transporter and subsequently produce neurotoxicity. The objective of this research is to show direct evidence of the formation of GSH adducts of MDMA in human hepatocytes. High-performance liquid chromatography coupled with tandem mass spectrometry was utilized to examine in vitro incubations of MDMA with cryopreserved human hepatocytes. The use of hydrophilic liquid chromatography in combination with linear ion trap mass spectrometry permitted the identification of two possible GSH metabolites. Enhanced product ion scans of m/z = 499 and 487 amu of extracts from hepatocytes treated with 1.0 mM MDMA show a distinct fragmentation pattern (m/z 194.2, 163, 135, 105), suggesting the formation of MDMA–GSH conjugate, MDMA-SG and 3,4-dihydroxymethamphetamine-SG. The formation of an MDMA–GSH conjugate was further supported by the apparent lack of the same fragmentation pattern from hepatocyte samples without MDMA treatment. The results generated from this study yield valuable qualitative and quantitative information about the neurotoxic thioether metabolites formed from MDMA in humans. PMID:24682111
Kadavilpparampu, Afsal Mohammed; Al-Lawati, Haider A J; Suliman, FakhrEldin O; Al Kindy, Salma M Z
2015-12-01
A novel automated precolumn derivatization followed by separation using liquid chromatography for the determination of pseudoephedrine (PSE) by a microfluidic chemiluminescence detector has been developed. An on-line derivatization procedure was utilized by converting PSE into a highly light emitting species in a Ru(bipy)3(2+)-peroxydisulphate chemiluminescence (CL) system by derivatizing it with a 1.0 M formaldehyde solution. The derivatized analyte was directly injected into a microbore high-performance liquid chromatography (HPLC) system coupled to an on-chip chemiluminescence detector. The newly developed highly selective, sensitive and fast HPLC-CL method was validated and successfully applied for the analysis of PSE in pharmaceutical formulations and a human urine sample. The selectivity of the method is not only due to the HPLC separation but is also due to the highly selective detection principle of the Ru(bipy)3(2+)-peroxydisulphate CL system used. There was no interference observed from the common preservatives and excipients used in pharmaceutical preparations, which did not show any significant CL signal. The retention time of PSE was less than 3 min, and the detection limits and quantification limits were found to be 5.7 and 26.0 µg L(-1), respectively. Copyright © 2015 John Wiley & Sons, Ltd.
He, Maofang; Wang, Chaozhan; Wei, Yinmao
2016-01-15
In this paper, iminodiacetic acid-Cu(II) functionalized Fe3O4@SiO2 magnetic nanoparticles were prepared and used as new adsorbents for magnetic solid phase extraction (MSPE) of six monoamine neurotransmitters (MNTs) from rabbit plasma. The selective enrichment of MNTs at pH 5.0 was motivated by the specific coordination interaction between amino groups of MNTs and the immobilized Cu(II). The employed weak acidic extraction condition avoided the oxidation of MNTs, and thus facilitated operation and ensured higher recoveries. Under optimal conditions, the recoveries of six MNTs from rabbit plasma were in the range of 83.9-109.4%, with RSD of 2.0-10.0%. When coupled the Cu(II) immobilized MSPE with high-performance liquid chromatography-fluorescence detection, the method exhibited relatively lower detection limits than the previously reported methods, and the method was successfully used to determine the endogenous MNTs in rabbit plasma. The proposed method has potential application for the determination of MNTs in biological samples. Also, the utilization of coordination interaction to improve the selectivity might open another way to selectively enrich small alkaloids from complex samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Rafferty, Jake L; Siepmann, J Ilja; Schure, Mark R
2009-03-20
Particle-based simulations using the configurational-bias and Gibbs ensemble Monte Carlo techniques are carried out to probe the effects of various chromatographic parameters on bonded-phase chain conformation, solvent penetration, and retention in reversed-phase liquid chromatography (RPLC). Specifically, we investigate the effects due to the length of the bonded-phase chains (C(18), C(8), and C(1)), the inclusion of embedded polar groups (amide and ether) near the base of the bonded-phase chains, the column pressure (1, 400, and 1000 atm), and the pore shape (planar slit pore versus cylindrical pore with a 60A diameter). These simulations utilize a bonded-phase coverage of 2.9 micromol/m(2)and a mobile phase containing methanol at a molfraction of 33% (about 50% by volume). The simulations show that chain length, embedded polar groups, and pore shape significantly alter structural and retentive properties of the model RPLC system, whereas the column pressure has a relatively small effect. The simulation results are extensively compared to retention measurements. A molecular view of the RPLC retention mechanism emerges that is more complex than can be inferred from thermodynamic measurements.
Liu, Dongyang; Jiang, Ji; Zhang, Li; Tan, Fenlai; Wang, Yingxiang; Hu, Pei
2011-08-15
Icotinib is a novel anti-cancer drug that has shown promising clinical efficacy and safety in patients with non-small-cell lung cancer (NSCLC). At this time, the metabolic fate of icotinib in humans is unknown. In the present study, a liquid chromatography/quadrupole time-of-flight tandem mass spectrometry (LC/Q-TOF MS) method was established to characterize metabolites of icotinib in human plasma, urine and feces. In addition, nuclear magnetic resonance (NMR) detection was utilized to determine the connection between side-chain and quinazoline groups for some complex metabolites. In total, 29 human metabolites (21 isomer metabolites) were characterized, of which 23 metabolites are novel compared to the metabolites in rats. This metabolic study revealed that icotinib was extensively metabolized at the 12-crown-4 ether moiety (ring-opening and further oxidation), carbon 15 (hydroxylation) and an acetylene moiety (oxidation) to yield 19 oxidized metabolites and to further form 10 conjugates with sulfate acid or glucuronic acid. To our knowledge, this is the first report of the human metabolic profile of icotinib. Study results indicated that significant attention should be paid to the metabolic profiles of NSCLC patients during the development of icotinib. Copyright © 2011 John Wiley & Sons, Ltd.
Darrington, Richard T; Jiao, Jim
2004-04-01
Rapid and accurate stability prediction is essential to pharmaceutical formulation development. Commonly used stability prediction methods include monitoring parent drug loss at intended storage conditions or initial rate determination of degradants under accelerated conditions. Monitoring parent drug loss at the intended storage condition does not provide a rapid and accurate stability assessment because often <0.5% drug loss is all that can be observed in a realistic time frame, while the accelerated initial rate method in conjunction with extrapolation of rate constants using the Arrhenius or Eyring equations often introduces large errors in shelf-life prediction. In this study, the shelf life prediction of a model pharmaceutical preparation utilizing sensitive high-performance liquid chromatography-mass spectrometry (LC/MS) to directly quantitate degradant formation rates at the intended storage condition is proposed. This method was compared to traditional shelf life prediction approaches in terms of time required to predict shelf life and associated error in shelf life estimation. Results demonstrated that the proposed LC/MS method using initial rates analysis provided significantly improved confidence intervals for the predicted shelf life and required less overall time and effort to obtain the stability estimation compared to the other methods evaluated. Copyright 2004 Wiley-Liss, Inc. and the American Pharmacists Association.
Le Guellec, C; Gaudet, M L; Breteau, M
1998-11-20
We report a high-performance liquid chromatography method for clonazepam determination in plasma. The use of a synthetic silica-based stationary phase markedly improved clonazepam resolution compared to standard reversed-phase columns. A liquid-liquid extraction was used, associated with reversed-phase chromatography, gradient elution and ultraviolet detection. Accuracy and precision were satisfactory at therapeutic concentrations. Selectivity was studied for benzodiazepines or other antiepileptic drugs, with particular attention to newly marketed drugs i.e., gabapentine and vigabatrin. No interfering substance was evidenced. Under the conditions described, it was possible to quantify clonazepam at nanogram level even when carbamazepine was present at therapeutic concentrations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Jung Hwa; Hyung, Seok-Won; Mun, Dong-Gi
2012-08-03
A multi-functional liquid chromatography system that performs 1-dimensional, 2-dimensional (strong cation exchange/reverse phase liquid chromatography, or SCX/RPLC) separations, and online phosphopeptides enrichment using a single binary nano-flow pump has been developed. With a simple operation of a function selection valve, which is equipped with a SCX column and a TiO2 (titanium dioxide) column, a fully automated selection of three different experiment modes was achieved. Because the current system uses essentially the same solvent flow paths, the same trap column, and the same separation column for reverse-phase separation of 1D, 2D, and online phosphopeptides enrichment experiments, the elution time information obtainedmore » from these experiments is in excellent agreement, which facilitates correlating peptide information from different experiments.« less
Jamalian, Azadeh; Sneekes, Evert-Jan; Wienk, Hans; Dekker, Lennard J. M.; Ruttink, Paul J. A.; Ursem, Mario; Luider, Theo M.; Burgers, Peter C.
2014-01-01
Here we describe a new method to identify calcium-binding sites in proteins using high-resolution liquid chromatography-mass spectrometry in concert with calcium-directed collision-induced dissociations. Our method does not require any modifications to the liquid chromatography-mass spectrometry apparatus, uses standard digestion protocols, and can be applied to existing high-resolution MS data files. In contrast to NMR, our method is applicable to very small amounts of complex protein mixtures (femtomole level). Calcium-bound peptides can be identified using three criteria: (1) the calculated exact mass of the calcium containing peptide; (2) specific dissociations of the calcium-containing peptide from threonine and serine residues; and (3) the very similar retention times of the calcium-containing peptide and the free peptide. PMID:25023127
Fan, Chen; Li, Nai; Cao, Xueli
2015-05-01
In-situ ionic liquid-dispersive liquid-liquid microextraction (IL-DLLME) method was developed as a pretreatment method for the detection of six chlorophenols (CPs) in honey samples. The hydrophobic ionic liquid [C4MIM][NTf2], formed in-situ by the hydrophilic ionic liquid [C4MIM][BF4] and the ion exchange reagent LiNTf2 was used as the microextractant solvent of CPs from honey sample. Then the enriched analytes were back-extracted into 40 μL of 0.14 M NaOH solution and finally subjected to analysis by high-performance liquid chromatography. The method showed low limit of detection of CPs, 0.8-3.2 μg/L and high enrichment factor, 34-65 with the recoveries range from 91.60% to 114.33%. The method is simple, rapid, environmentally friendly and with high extraction efficiency. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.
Protein separations using enhanced-fluidity liquid chromatography.
Bennett, Raffeal; Olesik, Susan V
2017-11-10
Enhanced-fluidity liquid chromatography (EFLC) methods using methanol/H 2 O/CO 2 and hydrophilic interaction liquid chromatography (HILIC) were explored for the separation of proteins and peptides. EFLC is a separation mode that uses a mobile phase made of conventional solvents combined with liquid carbon dioxide (CO 2 ) in subcritical conditions. The addition of liquid CO 2 enhances diffusivity and decreases viscosity while maintaining mixture polarity, which typically results in reduced time of analysis. TFA additive and elevated temperature were leveraged as key factors in the separation of a 13-analyte intact protein mixture in under 5min. Under these conditions EFLC showed modest improvement in terms of peak asymmetry and analysis time over the competing ACN/H 2 O separation. Protein analytes detected by electrospray ionization - quadrupole time of flight, were shown to be unaffected by the addition of CO 2 in the mobile phase. Herein, the feasibility of separating hydrophilic proteins up to 80kDa (with transferrin) is demonstrated for CO 2 -containing mobile phases. Copyright © 2017 Elsevier B.V. All rights reserved.
Tahan, Gabriella Padovani; Santos, Nayara de Kássia Souza; Albuquerque, Ana Carolina; Martins, Isarita
2016-08-01
Parabens are the most widely used preservative and are considered to be relatively safe compounds. However, studies have demonstrated that they may have estrogenic activity, and there is ongoing debate regarding the safety and potential cancer risk of using products containing these compounds. In the present work, liquid chromatography-tandem mass spectrometry was applied to determine methylparaben and propylparaben concentrations in serum, and the results were correlated with lipstick application. Samples were analyzed using liquid-liquid extraction, followed by liquid chromatography-tandem mass spectrometry. The validation results demonstrated the linearity of the method over a range of 1-20 ng/mL, in addition to the method's precision and accuracy. A statistically significant difference was demonstrated between serum parabens in women who used lipstick containing these substances compared with those not using this cosmetic (p = 0.0005 and 0.0016, respectively), and a strong association was observed between serum parabens and lipstick use (Spearman correlation = 0.7202). Copyright © 2016 Elsevier Inc. All rights reserved.
Diesel Engine Air Emissions Reduction Technologies
2010-04-01
Hour GC/MS Gas Chromatography /Mass Spectroscopy GC/FID Gas Chromatography /Flame Ionization Detector g/mile Gram per Mile HAP Hazardous Air...Pollutant HC Hydrocarbon HPLC/UV High Performance Liquid Chromatography / Ultraviolet KPa Kilo-Pascals NDIR Non Dispersive Infrared... Chromatography (GC) where the samples were collected on DNPH cartridges. Portable versions of these instruments were available and employed for
Szlag, David C; Sinclair, James L; Southwell, Benjamin; Westrick, Judy A
2015-06-12
An environmental protection agency EPA expert workshop prioritized three cyanotoxins, microcystins, anatoxin-a, and cylindrospermopsin (MAC), as being important in freshwaters of the United States. This study evaluated the prevalence of potentially toxin producing cyanobacteria cell numbers relative to the presence and quantity of the MAC toxins in the context of this framework. Total and potential toxin producing cyanobacteria cell counts were conducted on weekly raw and finished water samples from utilities located in five US states. An Enzyme-Linked Immunosorbant Assay (ELISA) was used to screen the raw and finished water samples for microcystins. High-pressure liquid chromatography with a photodiode array detector (HPLC/PDA) verified microcystin concentrations and quantified anatoxin-a and cylindrospermopsin concentrations. Four of the five utilities experienced cyanobacterial blooms in their raw water. Raw water samples from three utilities showed detectable levels of microcystins and a fourth utility had detectable levels of both microcystin and cylindrospermopsin. No utilities had detectable concentrations of anatoxin-a. These conventional plants effectively removed the cyanobacterial cells and all finished water samples showed MAC levels below the detection limit by ELISA and HPLC/PDA.
Cacho, J I; Campillo, N; Viñas, P; Hernández-Córdoba, M
2018-07-20
Nine organophosphorus pesticides (OPPs) were determined in environmental waters from different origins using in situ ionic liquid dispersive liquid microextraction (IL-DLLME). This preconcentration technique was coupled to gas chromatography-mass spectrometry (GC-MS) using microvial insert thermal desorption, an approach that uses a thermal desorption injector as sample introduction system. The parameters affecting both the microextraction and sample injection steps were optimized. The proposed method showed good precision, with RSD values ranging from 4.1 to 9.7%, accuracy with recoveries in the 85-118% range, and sensitivity with DLs ranging from 5 to 16 ng L -1 . Copyright © 2017 Elsevier B.V. All rights reserved.
2017-01-26
high- performance liquid chromatography (HPLC) and were greater than 95% unless otherwise noted. HPLC conditions to assess purity were as follows...cell culture plates using a μFlow liquid dispenser and cultured for 4 days at 37 °C. After incubation, the cells were allowed to equilibrate to 25...t1/2) was determined assuming first-order kinetics. LC/MS/MS Instrumentation Liquid chromatography was performed using an Agilent 1200-series
Flores, Gema; Díaz-Plaza, Eva María; Cortés, Jose Manuel; Villén, Jesús; Herraiz, Marta
2008-11-21
The use of absorbents as retaining materials in the through oven transfer adsorption desorption interface (TOTAD) of an on-line coupled reversed-phase liquid chromatography-gas chromatography system (RPLC-GC) is proposed for the first time. A comparative study of an adsorbent (Tenax TA) and two absorbents, namely polydimethylsiloxane and poly(50% phenyl/50% methylsiloxane) is performed to establish the best experimental conditions for the automated and simultaneous determination of 15 organophosphorus and organochlorine pesticide residues in olive oil. The proposed method provides satisfactory repeatability (RSDs lower, in general, than 8.5%) and sensitivity (limits of detection ranging from 0.6 to 81.9 microg/L) for the investigated compounds.
Kortz, Linda; Helmschrodt, Christin; Ceglarek, Uta
2011-03-01
In the last decade various analytical strategies have been established to enhance separation speed and efficiency in high performance liquid chromatography applications. Chromatographic supports based on monolithic material, small porous particles, and porous layer beads have been developed and commercialized to improve throughput and separation efficiency. This paper provides an overview of current developments in fast chromatography combined with mass spectrometry for the analysis of metabolites and proteins in clinical applications. Advances and limitations of fast chromatography for the combination with mass spectrometry are discussed. Practical aspects of, recent developments in, and the present status of high-throughput analysis of human body fluids for therapeutic drug monitoring, toxicology, clinical metabolomics, and proteomics are presented.
Godin, Jean-Philippe; McCullagh, James S O
2011-10-30
High-precision isotope analysis is recognized as an essential research tool in many fields of study. Until recently, continuous flow isotope ratio mass spectrometry (CF-IRMS) was available via an elemental analyzer or a gas chromatography inlet system for compound-specific analysis of light stable isotopes. In 2004, however, an interface that coupled liquid chromatography with IRMS (LC/IRMS) became commercially available for the first time. This brought the capability for new areas of application, in particular enabling compound-specific δ(13)C analysis of non-volatile, aqueous soluble, compounds from complex mixtures. The interface design brought with it several analytical constraints, however, in particular a lack of compatibility with certain types of chromatography as well as limited flow rates and mobile phase compositions. Routine LC/IRMS methods have, however, been established for measuring the δ(13)C isotopic ratios of underivatized individual compounds for application in archeology, nutrition and physiology, geochemistry, hydrology, soil science and food authenticity. Seven years after its introduction, we review the technical advances and constraints, methodological developments and new applications of liquid chromatography coupled to isotope ratio mass spectrometry. Copyright © 2011 John Wiley & Sons, Ltd.
Polymer Analysis by Liquid Chromatography/Electrospray Ionization Time-of-Flight Mass Spectrometry.
Nielen, M W; Buijtenhuijs, F A
1999-05-01
Hyphenation of liquid chromatography (LC) techniques with electrospray ionization (ESI) orthogonal acceleration time-of-flight (oa-TOF) mass spectrometry (MS) provides both MS-based structural information and LC-based quantitative data in polymer analysis. In one experimental setup, three different LC modes are interfaced with MS: size-exclusion chromatography (SEC/MS), gradient polymer elution chromatography (GPEC/MS), and liquid chromatography at the critical point of adsorption (LCCC/MS). In SEC/MS, both absolute mass calibration of the SEC column based on the polymer itself and determination of monomers and end groups from the mass spectra are achieved. GPEC/MS shows detailed chemical heterogeneity of the polymer and the chemical composition distribution within oligomer groups. In LCCC/MS, the retention behavior is primarily governed by chemical heterogeneities, such as different end group functionalities, and quantitative end group calculations can be easily made. The potential of these methods and the benefit of time-of-flight analyzers in polymer analysis are discussed using SEC/MS of a polydisperse poly(methyl methacrylate) sample, GPEC/MS of dipropoxylated bisphenol A/adipic acid polyester resin, LCCC/MS of alkylated poly(ethylene glycol), and LCCC/MS of terephthalic acid/neopentyl glycol polyester resin.
Jiménez, M; Mateo, R
1997-08-22
A method of analysis for trichothecenes (nivalenol, deoxynivalenol, 3- and 15-acetyldeoxynivalenol, diacetoxyscirpenol, neosolaniol, T-2 tetraol, T-2 and HT-2 toxins), zearalenone and zearalenols, and another method for determination of fumonisin B1 are described and applied to cultures of Fusarium isolated from bananas. Both methods were adapted from different techniques of extraction, clean-up and determination of these mycotoxins. The first method involves extraction with methanol-1% aqueous sodium chloride, clean-up of extracts by partition with hexane and dichloromethane, additional solid reversed-phase clean-up and analysis of two eluates by both high-performance liquid chromatography with ultraviolet detection and capillary gas chromatography. The method for fumonisin B1 implies extraction with aqueous methanol, concentration, clean-up with water and methanol on Amberlite XAD-2 column, formation of a fluorescent 4-fluoro-7-nitrobenzofurazan derivative and analysis by high-performance liquid chromatography with fluorescence detection. Both procedures give good limits of detection and recoveries, and are considered suitable for the detection and quantification of the studied toxins in corn and rice cultures of Fusarium spp. isolated from banana fruits.
Lipidomics in triacylglycerol and cholesteryl ester oxidation.
Kuksis, Arnis
2007-05-01
Although direct mass spectrometry is capable of identification the major molecular species of lipids in crude total lipid extracts, prior chromatographic isolation is necessary for detection and identification of the minor components. This is especially important for the analysis of the oxolipids, which usually occur in trace amounts in the total lipid extract, and require prior isolation for detailed analysis. Both thin-layer chromatography and adsorption cartridges provide effective means for isolation and enrichment of lipid classes, while gas-liquid chromatography and high performance liquid chromatography with on-line mass spectrometry permit further separation and identification of molecular species. Prior chromatographic resolution is absolutely necessary for the identification of isobaric and chiral molecules, which mass spectrometry/mass spectrometry (MS/MS) cannot distinguish. Both gas chromatography-mass spectrometry and liquid chromatography-mass spectrometry applications may require the preparation of derivatives in order to improve the chromatographic and mass spectrometric properties of the oxolipids which is a small inconvenience for securing analytical reliability. The following chapter reviews the advantages and necessity of combined chromatographic-mass spectrometric approaches to successful identification and quantification of molecular species of oxoacylglycerols and oxocholesteryl esters in in-vitro model studies of lipid peroxidation and in the analyses of oxolipids recovered from tissues.
Experiments for Modern Introductory Chemistry.
ERIC Educational Resources Information Center
Kildahl, Nicholas; Berka, Ladislav H.
1995-01-01
Presents a headspace gas chromatography experiment that enables discovery of the temperature dependence of the vapor pressure of a pure liquid. Illustrates liquid-vapor phase equilibrium of pure liquids. Contains 22 references. (JRH)
Micellar liquid chromatography
NASA Astrophysics Data System (ADS)
Basova, Elena M.; Ivanov, Vadim M.; Shpigun, Oleg A.
1999-12-01
Background and possibilities of practical applications of micellar liquid chromatography (MLC) are considered. Various retention models in MLC, the effects of the nature and concentration of surfactants and organic modifiers, pH, temperature and ionic strength on the MLC efficiency and selectivity are discussed. The advantages and limitations of MLC are demonstrated. The performance of MLC is critically evaluated in relationship to the reversed-phase HPLC and ion-pair chromatography. The potential of application of MLC for the analysis of pharmaceuticals including that in biological fluids and separation of inorganic anions, transition metal cations, metal chelates and heteropoly compounds is described. The bibliography includes 146 references.
Physicochemical application of capillary chromatography
NASA Astrophysics Data System (ADS)
Vasil'ev, A. V.; Aleksandrov, E. N.
1992-04-01
The application of capillary gas chromatography in the determination of the free energy, enthalpy, and entropy of sorption, the saturated vapour pressure and activity coefficients, the assessment of the lipophilicity of volatile compounds, and the study of the properties of polymers and liquid crystals is described. The use of reaction cappillary chromatography in kinetic studies of conformational conversions, thermal degradation, and photochemical reactions is examined. Studies on the use of capillary columns for determination of the second virial coefficients and viscosity of gases and the diffusion coefficients in gases, liquids, supercritical fluids, and polymers are analysed. The bibliography includes 114 references.
Onishi, S; Itoh, S; Ishida, Y
1982-01-01
An accurate and sensitive method that involves the group separations of serum bile acids (i.e. free and glycine- and taurine-conjugated bile acid fractions) by ion-exchange chromatography on piperidinohydroxypropyl-Sephadex LH-20 is described. Each group was then analysed by high-pressure liquid chromatography by using the post-column reaction technique with immobilized 3 alpha-hydroxy steroid dehydrogenase. The bile acid patterns in the umbilical venous serum samples were analysed by this method. Taurochenodeoxycholate predominated in the umbilical blood. PMID:6956336
Ceppa, F; Drouillard, I; Chianea, D; Burnat, P; Perrier, F; Vaillant, C; El Jahiri, Y
1999-01-01
Cardio-vascular diseases are the most common cause of death in industrialized countries. A new marker has emerged among offending risk factors in the past few years: homocysteine. This sulphured amino-acid is an important intermediate in transsulphuration and remethylation reactions of methionine's metabolism. We proposed to evaluate a home made method of determination for this parameter by high performance liquid chromatography (HPLC) and to compare it to fluorescence polarization immunoassay technique (FPIA) and to gaz phase chromatography (CG-SM). This method associated with good sensibility and precision remain much less expensive than FPIA technique.
Huang, Tao; He, Jiang
2017-01-01
Extracellular vesicles (EVs) have recently attracted substantial attention due to the potential diagnostic and therapeutic relevance. Although a variety of techniques have been used to isolate and analyze EVs, it is still far away from satisfaction. Size-exclusion chromatography (SEC), which separates subjects by size, has been widely applied in protein purification and analysis. The purpose of this chapter is to show the applications of size-exclusion high-performance liquid chromatography (HPLC) as methods for EV characterization of impurities or contaminants of small size, and thus for quality assay for the purity of the samples of EVs.
2009-03-01
Waste heat from a pulse detonation engine (PDE) was extracted via concentric, counter flow heat exchangers to produce supercritical pyrolytic...mass spectrometry HLPC = High performance liquid chromatography NPT = National pipe thread PAH = Polycyclic aromatic hydrocarbon PDE = Pulse...Precision Liquid Chromatography (HPLC). The resulting “stressed” fuel showed a 29 shift to lower molecular weight compounds, as well as the production
This method provides a procedure for determination of chlorophylls a (chl a) and b (chl b) found in marine and freshwater phytoplankton. Reversed phase high performance liquid chromatography (HPLC) with detection at 440 nm is used to separate the pigments from a complex pigment ...
Yamada, H; Fukumura, T; Ito, Y; Imoto, T
1985-04-01
Preparation of chitin-coated Celite as an affinity adsorbent for high-performance liquid chromatography of lysozymes and its application to separation of N-bromosuccinimide-oxidized lysozymes are described. By pH gradient elution, two diastereomers of oxindolealanine-62-lysozyme, delta 1-acetoxytryptophan-62-lysozyme (intermediate product in the reaction in acetate buffer), and native lysozyme were all separated within 40 min.
Comeau, Yves; Hall, Kenneth J.; Oldham, William K.
1988-01-01
A convenient gas-liquid chromatography procedure to quantify poly-β-hydroxybutyrate and poly-β-hydroxyvalerate in activated sludge was developed by combining lyophilization of the samples, purification of the chloroform phase by water reextraction, and the use of capillary columns. With a flame ionization detector the sensitivity was estimated at 10−5 g/liter. PMID:16347745
Lodi, A; Angus, M; Nap, C J; Skellern, G; Nicolas, A
2015-01-01
A liquid chromatography coupled with charged aerosol detection (LC-CAD) procedure; capable of separating and quantifying the most common impurities of valine at levels as low as 0.05 per cent (m/m), has been developed. The procedure is simple (isocratic), rapid, linear, sensitive and repeatable. It employs a widely available and inexpensive stationary phase (C18).
ERIC Educational Resources Information Center
Xu, Xia; Veenstra, Timothy D.
2012-01-01
The list of physiological events in which sex steroids play a role continues to increase. To decipher the roles that sex steroids play in any condition requires high quality cohorts of samples and assays that provide highly accurate quantitative measures. Liquid and gas chromatography coupled with mass spectrometry (LC-MS and GC-MS) have…
ERIC Educational Resources Information Center
Revell, Kevin D.
2011-01-01
A new laboratory experiment is described in which students compare two benchtop separation methods to isolate the three active components of the commercial analgesic Excedrin. In the two-week sequence, aspirin, acetaminophen, and caffeine are separated using either a two-base liquid-liquid extraction or silica column chromatography. Students then…
High-pressure liquid chromatography of aromatic amines
NASA Technical Reports Server (NTRS)
Young, P. R.
1979-01-01
Analysis made on commercially available liquid chromatograph demonstrates high-pressure liquid chromatographic conditions for separation of approximately 50 aromatic amines ranging from simple aniline derivatives to complex multiring di- and tri-amines.
Han, Shengli; Huang, Jing; Cui, Ronghua; Zhang, Tao
2015-02-01
Carthamus tinctorius, used in traditional Chinese medicine, has many pharmacological effects, such as anticoagulant effects, antioxidant effects, antiaging effects, regulation of gene expression, and antitumor effects. However, there is no report on the antiallergic effects of the components in C. tinctorius. In the present study, we investigated the antiallergic components of C. tinctorius and its mechanism of action. A rat basophilic leukemia 2H3/cell membrane chromatography coupled online with high-performance liquid chromatography and tandem mass spectrometry method was developed to screen antiallergic components from C. tinctorius. The screening results showed that Hydroxysafflor yellow A, from C. tinctorius, was the targeted component that retained on the rat basophilic leukemia 2H3/cell membrane chromatography column. We measured the amount of β-hexosaminidase and histamine released in mast cells and the key markers of degranulation. The release assays showed that Hydroxysafflor yellow A could attenuate the immunoglobulin E induced release of allergic cytokines without affecting cell viability from 1.0 to 50.0 μM. In conclusion, the established rat basophilic leukemia 2H3 cell membrane chromatography coupled with online high-performance liquid chromatography and tandem mass spectrometry method successfully screened and identified Hydroxysafflor yellow A from C. tinctorius as a potential antiallergic component. Pharmacological analysis elucidated that Hydroxysafflor yellow A is an effective natural component for inhibiting immunoglobulin E-antigen-mediated degranulation. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Desfontaine, Vincent; Nováková, Lucie; Ponzetto, Federico; Nicoli, Raul; Saugy, Martial; Veuthey, Jean-Luc; Guillarme, Davy
2016-06-17
This work describes the development of two methods involving supported liquid extraction (SLE) sample treatment followed by ultra-high performance liquid chromatography or ultra-high performance supercritical fluid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS and UHPSFC-MS/MS) for the screening of 43 anabolic agents in human urine. After evaluating different stationary phases, a polar-embedded C18 and a diol columns were selected for UHPLC-MS/MS and UHPSFC-MS/MS, respectively. Sample preparation, mobile phases and MS conditions were also finely tuned to achieve highest selectivity, chromatographic resolution and sensitivity. Then, the performance of these two methods was compared to the reference routine procedure for steroid analyses in anti-doping laboratories, which combines liquid-liquid extraction (LLE) followed by gas chromatography coupled to tandem mass spectrometry (GC-MS/MS). For this purpose, urine samples spiked with the compounds of interest at five different concentrations were analyzed using the three analytical platforms. The retention and selectivity of the three techniques were very different, ensuring a good complementarity. However, the two new methods displayed numerous advantages. The overall procedure was much faster thanks to high throughput SLE sample treatment using 48-well plates and faster chromatographic analysis. Moreover, the highest sensitivity was attained using UHPLC-MS/MS with 98% of the doping agents detected at the lowest concentration level (0.1ng/mL), against 76% for UHPSFC-MS/MS and only 14% for GC-MS/MS. Finally, the weakest matrix effects were obtained with UHPSFC-MS/MS with 76% of the analytes displaying relative matrix effect between -20 and 20%, while the GC-MS/MS reference method displayed very strong matrix effects (over 100%) for all of the anabolic agents. Copyright © 2016 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Usher, Karyn M.; Simmons, Carolyn R.; Keating, Daniel W.; Rossi, Henry F., III
2015-01-01
Chemical separations are an important part of an undergraduate chemistry curriculum. Sophomore students often get experience with liquid-liquid extraction in organic chemistry classes, but liquid-liquid extraction is not as often introduced as a quantitative sample preparation method in honors general chemistry or quantitative analysis classes.…
Gergov, M; Ojanperä, I; Vuori, E
2003-09-25
A liquid chromatography-tandem mass spectrometry (LC-MS-MS) method is presented for the qualitative screening for 238 drugs in blood samples, which is considerably more than in previous methods. After a two-step liquid-liquid extraction and C(18) chromatography, the compounds were introduced into a triple quadrupole mass spectrometer equipped with a turbo ion spray ion source operating in the positive ionization mode. Identification was based on the compound's absolute retention time, protonated molecular ion, and one representative fragment ion obtained by multiple reaction monitoring (MRM) at an individually selected collision energy of 20, 35, or 50 eV. The limit of detection (LOD) for the majority of the compounds (80%) was < or = 0.05 mg/l, ranging from 0.002 mg/l (e.g., antihistamines) to 5 mg/l (acidic compounds), and for malathion it was 10 mg/l. The LOD values were sufficiently low to allow the majority of compounds to be detected at therapeutic concentrations in the blood.
Cavedal, Luiz E; Mendes, Fabiana D; Domingues, Claudia C; Patni, Anil K; Monif, Tausif; Reyar, Simrit; Pereira, Alberto Dos S; Mendes, Gustavo D; De Nucci, Gilberto
2007-01-01
A rapid, sensitive and specific method for quantifying clonazepam in human plasma using diazepam as the internal standard (IS) is described. The analyte and the IS were extracted from plasma by liquid-liquid extraction using a hexane/diethylether (20 : 80, v/v) solution. The extracts were analysed by high-performance liquid chromatography coupled with electrospray tandem mass spectrometry (HPLC-MS-MS). Chromatography was performed on a Jones Genesis C8 4 microm analytical column (100 x 2.1 mm i.d.). The method had a chromatographic run time of 3.0 min and a linear calibration curve over the range 0.5-50 ng/ml (r2 > 0.9965). The limit of quantification was 0.5 ng/ml. This HPLC/MS/MS procedure was used to assess the bioequivalence of two clonazepam 2 mg tablet formulations (clonazepam test formulation from Ranbaxy Laboratories Ltd and Rivotril from Roche Laboratórios Ltda as standard reference formulation). Copyright 2006 John Wiley & Sons, Ltd.
He, Jianfeng; Fan, Jun; Yan, Yilun; Chen, Xiaodong; Wang, Tai; Zhang, Yaomou; Zhang, Weiguang
2016-11-01
Enantiomeric pairs of triticonazole have been successfully separated by supercritical fluid chromatography coupled with a tris(3,5-dimethylphenylcarbamoyl) cellulose-coated chiral stationary phase in this work. The effects of co-solvent, dissolution solvent, flow rate, backpressure, and column temperature have been studied in detail with respect to retention, selectivity, and resolution of triticonazole. As indicated, the co-solvents mostly affected the retention factors and resolution, due to the different molecular structure and polarity. In addition, the dissolution solvents, namely, chloromethanes and alcohols, have been also important for enantioseparation because of the different interaction with stationary phase. Higher flow rate and backpressure led to faster elution of the triticonazole molecules, and the change of column temperature showed slight effect on the resolution of triticonazole racemate. Moreover, a comparative separation experiment between supercritical fluid chromatography and high performance liquid chromatography revealed that chiral supercritical fluid chromatography gave the 3.5 times value of R s /t R2 than high performance liquid chromatography, which demonstrated that supercritical fluid chromatography had much higher separation efficiency. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Liu, Zhao-Ying
2012-12-01
Metabolism studies play an important role at various stages of drug discovery and development. Liquid chromatography combined with mass spectrometry (LC/MS) has become a most powerful and widely used analytical tool for identifying drug metabolites. The suitability of different types of mass spectrometers for metabolite profiling differs widely, and therefore, the data quality and reliability of the results also depend on which instrumentation is used. As one of the latest LC/MS instrumentation designs, hybrid ion trap/time-of-flight MS coupled with LC (LC-IT-TOF-MS) has successfully integrated ease of operation, compatibility with LC flow rates and data-dependent MS(n) with high mass accuracy and mass resolving power. The MS(n) and accurate mass capabilities are routinely utilized to rapidly confirm the identification of expected metabolites or to elucidate the structures of uncommon or unexpected metabolites. These features make the LC-IT-TOF-MS a very powerful analytical tool for metabolite identification. This paper begins with a brief introduction to some basic principles and main properties of a hybrid IT-TOF instrument. Then, a general workflow for metabolite profiling using LC-IT-TOF-MS, starting from sample collection and preparation to final identification of the metabolite structures, is discussed in detail. The data extraction and mining techniques to find and confirm metabolites are discussed and illustrated with some examples. This paper is directed to readers with no prior experience with LC-IT-TOF-MS and will provide a broad understanding of the development and utility of this instrument for drug metabolism studies. Copyright © 2012 John Wiley & Sons, Ltd.
Taylor, Michael J; Keenan, George A; Reid, Kirsty B; Fernández, Diana Uría
2008-09-01
The utility of ultra-performance liquid chromatography/orthogonal-acceleration time-of flight mass spectrometry (UPLC/TOFMS) for the rapid qualitative and quantitative analysis of 100 pesticides targeted in strawberry was assessed by comparing results with those obtained using a validated in-house UPLC tandem mass spectrometry (MS/MS) multi-residue method. Crude extracts from retail strawberry samples received as part of the 2007 annual UK pesticide residues in food surveillance programme were screened for the presence of pesticide residues using UPLC/TOFMS. Accurate mass measurement of positive and negative ions allowed their extraction following 'full mass range data acquisition' with negligible interference from background or co-eluting species observed during UPLC gradient separation (in a cycle time of just 6.5 min per run). Extracted ion data was used to construct calibration curves and to detect and identify any incurred residues (i.e. pesticides incorporated in or on the test material following application during cultivation, harvest and storage). Calibration using matrix-matched standards was performed over a narrow concentration range of 0.005-0.04 mg kg(-1) with determination coefficients (r2) > or =0.99 for all analytes with the exception of malathion/fenarimol/fludioxanil (r2 = 0.98), quassia/pymetrazine (r2 = 0.97) and fenthion sulfone (r2 = 0.95). Residues found in selected samples ranged from 0.025-0.28 mg kg(-1) and were in excellent agreement with results obtained using UPLC/MS/MS. Mass measurement accuracies of < or =5 ppm were achieved consistently throughout the separation, mass range and concentration range of interest thus providing the opportunity to obtain discrete elemental compositions of target ions.
He, Jianyu; Han, Shengli; Yang, Fangfang; Zhou, Nan; Wang, Sicen
2013-01-01
Uncaria rhynchophylla is a traditional Chinese medicinal herb used to treat hypertension and convulsive disorders such as epilepsy. Rat prostate cell membrane chromatography combined with liquid chromatography-mass spectrometry (LC-MS) was used to identify active constituents from U. rhynchophylla extracts. Four compounds (corynoxeine, isorhynchophylline, isocorynoxeine and rhynchophylline) were discovered. Competitive binding assay results indicated that the four compounds were in direct competition at a single common binding site and interacted with α1A adrenergic receptors (α1A-AR) in a manner similar to tamsulosin. Affinity constant values of the four compounds binding with α1A-AR were also measured using rat prostate cell membrane chromatography (CMC). Finally, their pharmacodynamic effects were tested on rat caudal arteries. This CMC combined LC-MS system offers a means of drug discovery by screening natural medicinal herbs for new pharmacologically active molecules targeting specific receptors.
Kaale, Eliangiringa; Van Schepdael, Ann; Roets, Eugène; Hoogmartens, Jos
2002-11-07
A reversed-phase liquid chromatography (LC) method has been developed, optimised and validated for the separation and quantitation of capsaicin (CP) and dihydrocapsaicin (DHCP) in a topical cream formulation. Sample preparation involves liquid-liquid extraction prior to LC analysis. The method uses a Hypersil C(18) BDS, 5 micrometer, 250x4.6 mm I.D. column maintained at 35 degrees C. The mobile phase comprises methanol, water, acetonitrile (ACN) and acetic acid (47:42:10:1, v/v/v/v) at a flow rate of 1.0 ml/min. Robustness was evaluated by performing a central composite face-centred design (CCF) experiment. The method shows good selectivity, linearity, sensitivity and repeatability. The conditions allow the separation and quantitation of CP and DHCP without interference from the other substances contained in the cream.
Kaufmann, A; Butcher, P; Maden, K; Walker, S; Widmer, M
2010-07-12
The selectivity of mass traces obtained by monitoring liquid chromatography coupled to high resolution mass spectrometry (LC-HRMS) and liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) was compared. A number of blank extracts (fish, pork kidney, pork liver and honey) were separated by ultra performance liquid chromatography (UPLC). Detected were some 100 dummy transitions respectively dummy exact masses (traces). These dummy masses were the product of a random generator. The range of the permitted masses corresponded to those which are typical for analytes (e.g. veterinary drugs). The large number of monitored dummy traces ensured that endogenous compounds present in the matrix extract, produced a significant number of detectable chromatographic peaks. All obtained chromatographic peaks were integrated and standardized. Standardisation was done by dividing these absolute peak areas by the average response of a set of 7 different veterinary drugs. This permitted a direct comparison between the LC-HRMS and LC-MS/MS data. The data indicated that the selectivity of LC-HRMS exceeds LC-MS/MS, if high resolution mass spectrometry (HRMS) data is recorded with a resolution of 50,000 full width at half maximum (FWHM) and a corresponding mass window. This conclusion was further supported by experimental data (MS/MS based trace analysis), where a false positive finding was observed. An endogenous matrix compound present in honey matrix behaved like a banned nitroimidazole drug. This included identical retention time and two MRM traces, producing an MRM ratio between them, which perfectly matched the ratio observed in the external standard. HRMS measurement clearly resolved the interfering matrix compound and unmasked the false positive MS/MS finding. Copyright 2010 Elsevier B.V. All rights reserved.
Muñoz, Marcelo A; González, Natalia; Joseph-Nathan, Pedro
2016-07-01
The absolute configuration of the naturally occurring isomers of 6β-benzoyloxy-3α-tropanol (1) has been established by the combined use of chiral high-performance liquid chromatography with electronic circular dichroism detection and optical rotation detection. For this purpose (±)-1, prepared in two steps from racemic 6-hydroxytropinone (4), was subjected to chiral high-performance liquid chromatography with electronic circular dichroism and optical rotation detection allowing the online measurement of both chiroptical properties for each enantiomer, which in turn were compared with the corresponding values obtained from density functional theory calculations. In an independent approach, preparative high-performance liquid chromatography separation using an automatic fraction collector, yielded an enantiopure sample of OR (+)-1 whose vibrational circular dichroism spectrum allowed its absolute configuration assignment when the bands in the 1100-950 cm(-1) region were compared with those of the enantiomers of esters derived from 3α,6β-tropanediol. In addition, an enantiomerically enriched sample of 4, instead of OR (±)-4, was used for the same transformation sequence, whose high-performance liquid chromatography follow-up allowed their spectroscopic correlation. All evidences lead to the OR (+)-(1S,3R,5S,6R) and OR (-)-(1R,3S,5R,6S) absolute configurations, from where it follows that samples of 1 isolated from Knightia strobilina and Erythroxylum zambesiacum have the OR (+)-(1S,3R,5S,6R) absolute configuration, while the sample obtained from E. rotundifolium has the OR (-)-(1R,3S,5R,6S) absolute configuration. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.