Transmission of FDDI signals over low-frequency media
NASA Astrophysics Data System (ADS)
Ater, Dan
1992-03-01
The `FDDI' designation is gaining an increasing place in the local area network (LAN) jargon along with the `Ethernet' and `Token Ring.' The four letters stand for fiber-optic distributed data interface, but as in the case of other LANs the meaning of the name looses its importance as the properties of the network become familiar to the community of the users, implementors, and designers. Further, more new properties are added to the original set, sometimes beyond the boundaries hinted by the name. This paper presents the actual stage of an attempt to change the `F' (fiber-optic) to `M' (metal) specifically to unshielded twisted pair (UTP). The sense in doing so is the fact that a huge installed basis of metallic wires for telephone and data transmission already exists, and reaches an immense number of desktops. This paper describes: (1) An hierarchical network architecture emphasizing the segment to be implemented over UTP. (2) A systemic approach to the definition of the parameters for the physical medium dependent (PMD) module that should interface the MDDI (FDDI over metallic media) to the UTP cable plant. (3) Measurement results available at the time of the presentation.
2016-03-01
Howley, “What Is NFC, and Why Does it Matter for the iPhone 6?” Yahoo , September 3, 2014, https://www.yahoo.com/tech/what-is-nfc-and-why-does-it...www.wired.com/ 2006/06/crowds. Howley, Daniel. “What Is NFC, and Why Does it Matter for the iPhone 6?” Yahoo . September 3, 2014. https
... Power lines Electrical wiring Microwave ovens Computers Cell phones Some people worry about EMF exposure and cancer. ... cancer. Some people worry that wireless and cellular phones cause cancer or other health problems. The phones ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ashley, G.W.; Harris, G.; Stubbe, J.
1988-10-04
The ribonucleoside triphosphate reductase of Lactobacillus leichmannii converts the substrate analogue 2{prime}-chloro-2{prime}-deoxyuridine 5{prime}-triphosphate (C1UTP) into a mixture of 2{prime}-deoxyuridine triphosphate (dUTP) and the unstable product 3{prime}-keto-2{prime}-deoxyuridine triphosphate (3{prime}-keto-dUTP). This ketone can be trapped by reduction with NaBH{sub 4}, producing a 4:1 mixture of xylo-dUTP and dUTP. When (3{prime}-{sup 3}H)C1UTP is treated with enzyme in the presence of NaBH{sub 4}, the isomeric deoxyuridines isolated after alkaline phosphatase treatment retained 15% of the {sup 3}H in C1UTP. Degradation of these isomeric nucleosides has established the location of the {sup 3}H in 3{prime}-keto-dUTP as predominantly 2{prime}(S). The xylo-dU had 98.6% of its labelmore » at the 2{prime}(S) position and 1.5% at 2{prime}(R). The isolated dU had 89.6% of its label at 2{prime}(S) and 1.4% at 2{prime}(R), with the remaining 9% label inferred to be at the 3{prime}-carbon, this resulting from the direct enzymic production of dUTP. These results are consistent with enzymic production of a 1:1,000 mixture of dUTP and 3{prime}-keto-dUTP, where the 3{prime}-hydrogen of C1UTP is retained at 3{prime} during production of dUTP and is transferred to 2{prime}(S) during production of 3{prime}-keto-dUTP. The implications of these results and the unique role of the cofactor adenosylcobalamin are discussed in terms of reductase being a model for the B{sub 12}-dependent rearrangement reactions.« less
Liu, Mei-Li; Wen, Jian-Qiang; Fan, Yu-Bo
2011-10-01
Radiofrequency electromagnetic fields (EMF) are harmful to public health, but the certain anti-irradiation mechanism is not clear yet. The present study was performed to investigate the possible protective effects of green tea polyphenols against electromagnetic radiation-induced injury in the cultured rat cortical neurons. In this study, green tea polyphenols were used in the cultured cortical neurons exposed to 1800 MHz EMFs by the mobile phone. We found that the mobile phone irradiation for 24 h induced marked neuronal cell death in the MTT (3-(4,5-dimethylthiazole-2-yl)-2,5-diphenyl-tetrazolium bromide) and TUNEL (TdT mediated biotin-dUTP nicked-end labeling) assay, and protective effects of green tea polyphenols on the injured cortical neurons were demonstrated by testing the content of Bcl-2 Assaciated X protein (Bax) in the immunoprecipitation assay and Western blot assay. In our study results, the mobile phone irradiation-induced increases in the content of active Bax were inhibited significantly by green tea polyphenols, while the contents of total Bax had no marked changes after the treatment of green tea polyphenols. Our results suggested a neuroprotective effect of green tea polyphenols against the mobile phone irradiation-induced injury on the cultured rat cortical neurons.
Home and School Technology: Wired versus Wireless.
ERIC Educational Resources Information Center
Van Horn, Royal
2001-01-01
Presents results of informal research on smart homes and appliances, structured home wiring, whole-house audio/video distribution, hybrid cable, and wireless networks. Computer network wiring is tricky to install unless all-in-one jacketed cable is used. Wireless phones help installers avoid pre-wiring problems in homes and schools. (MLH)
Code of Federal Regulations, 2010 CFR
2010-07-01
..., however, that where trolley phones and telephones are both used, an alternate source of power for the trolley phone system is not required. (d) Trolley phones connected to the trolley wire shall be grounded...
Liñán-Rico, Andromeda; Ochoa-Cortes, Fernando; Zuleta-Alarcon, Alix; Alhaj, Mazin; Tili, Esmerina; Enneking, Josh; Harzman, Alan; Grants, Iveta; Bergese, Sergio; Christofi, Fievos L.
2017-01-01
Background: Enterochromaffin cells (EC) synthesize and release 5-HT and ATP to trigger or modulate gut neural reflexes and transmit information about visceral/pain sensation. Alterations in 5-HT signaling mechanisms may contribute to the pathogenesis of IBD or IBS, but the pharmacologic or molecular mechanisms modulating Ca2+-dependent 5-HT release are not understood. Previous studies indicated that purinergic signaling via ATP and ADP is an important mechanism in modulation of 5-HT release. However, EC cells also respond to UTP and UDP suggesting uridine triphosphate receptor and signaling pathways are involved as well. We tested the hypothesis that UTP is a regulator of 5-HT release in human EC cells. Methods: UTP signaling mechanisms were studied in BON cells, a human EC model, using Fluo-4/Ca2+imaging, patch-clamp, pharmacological analysis, immunohistochemistry, western blots and qPCR. 5-HT release was monitored in BON or EC isolated from human gut surgical specimens (hEC). Results: UTP, UTPγS, UDP or ATP induced Ca2+oscillations in BON. UTP evoked a biphasic concentration-dependent Ca2+response. Cells responded in the order of UTP, ATP > UTPγS > UDP >> MRS2768, BzATP, α,β-MeATP > MRS2365, MRS2690, and NF546. Different proportions of cells activated by UTP and ATP also responded to UTPγS (P2Y4, 50% cells), UDP (P2Y6, 30%), UTPγS and UDP (14%) or MRS2768 (<3%). UTP Ca2+responses were blocked with inhibitors of PLC, IP3R, SERCA Ca2+pump, La3+sensitive Ca2+channels or chelation of intracellular free Ca2+ by BAPTA/AM. Inhibitors of L-type, TRPC, ryanodine-Ca2+pools, PI3-Kinase, PKC or SRC-Kinase had no effect. UTP stimulated voltage-sensitive Ca2+currents (ICa), Vm-depolarization and inhibited IK (not IA) currents. An IKv7.2/7.3 K+ channel blocker XE-991 mimicked UTP-induced Vm-depolarization and blocked UTP-responses. XE-991 blocked IK and UTP caused further reduction. La3+ or PLC inhibitors blocked UTP depolarization; PKC inhibitors, thapsigargin or zero Ca2+buffer did not. UTP stimulated 5-HT release in hEC expressing TPH1, 5-HT, P2Y4/P2Y6R. Zero-Ca2+buffer augmented Ca2+responses and 5-HT release. Conclusion: UTP activates a predominant P2Y4R pathway to trigger Ca2+oscillations via internal Ca2+mobilization through a PLC/IP3/IP3R/SERCA Ca2+signaling pathway to stimulate 5-HT release; Ca2+influx is inhibitory. UTP-induced Vm-depolarization depends on PLC signaling and an unidentified K channel (which appears independent of Ca2+oscillations or Ica/VOCC). UTP-gated signaling pathways triggered by activation of P2Y4R stimulate 5-HT release. PMID:28751862
Liñán-Rico, Andromeda; Ochoa-Cortes, Fernando; Zuleta-Alarcon, Alix; Alhaj, Mazin; Tili, Esmerina; Enneking, Josh; Harzman, Alan; Grants, Iveta; Bergese, Sergio; Christofi, Fievos L
2017-01-01
Background: Enterochromaffin cells (EC) synthesize and release 5-HT and ATP to trigger or modulate gut neural reflexes and transmit information about visceral/pain sensation. Alterations in 5-HT signaling mechanisms may contribute to the pathogenesis of IBD or IBS, but the pharmacologic or molecular mechanisms modulating Ca 2+ -dependent 5-HT release are not understood. Previous studies indicated that purinergic signaling via ATP and ADP is an important mechanism in modulation of 5-HT release. However, EC cells also respond to UTP and UDP suggesting uridine triphosphate receptor and signaling pathways are involved as well. We tested the hypothesis that UTP is a regulator of 5-HT release in human EC cells. Methods: UTP signaling mechanisms were studied in BON cells, a human EC model, using Fluo-4/Ca 2+ imaging, patch-clamp, pharmacological analysis, immunohistochemistry, western blots and qPCR. 5-HT release was monitored in BON or EC isolated from human gut surgical specimens (hEC). Results: UTP, UTPγS, UDP or ATP induced Ca 2+ oscillations in BON. UTP evoked a biphasic concentration-dependent Ca 2+ response. Cells responded in the order of UTP, ATP > UTPγS > UDP > MRS2768, BzATP, α,β-MeATP > MRS2365, MRS2690, and NF546. Different proportions of cells activated by UTP and ATP also responded to UTPγS (P2Y 4 , 50% cells), UDP (P2Y 6 , 30%), UTPγS and UDP (14%) or MRS2768 (<3%). UTP Ca 2+ responses were blocked with inhibitors of PLC, IP3R, SERCA Ca 2+ pump, La 3+ sensitive Ca 2+ channels or chelation of intracellular free Ca 2+ by BAPTA/AM. Inhibitors of L-type, TRPC, ryanodine-Ca 2+ pools, PI3-Kinase, PKC or SRC-Kinase had no effect. UTP stimulated voltage-sensitive Ca 2+ currents (I Ca ), V m -depolarization and inhibited I K (not I A ) currents. An I Kv 7.2/7.3 K + channel blocker XE-991 mimicked UTP-induced V m -depolarization and blocked UTP-responses. XE-991 blocked I K and UTP caused further reduction. La 3+ or PLC inhibitors blocked UTP depolarization; PKC inhibitors, thapsigargin or zero Ca 2+ buffer did not. UTP stimulated 5-HT release in hEC expressing TPH1, 5-HT, P2Y 4 /P2Y 6 R. Zero-Ca 2+ buffer augmented Ca 2+ responses and 5-HT release. Conclusion: UTP activates a predominant P2Y 4 R pathway to trigger Ca 2+ oscillations via internal Ca 2+ mobilization through a PLC/IP 3 /IP3R/SERCA Ca 2+ signaling pathway to stimulate 5-HT release; Ca 2+ influx is inhibitory. UTP-induced V m -depolarization depends on PLC signaling and an unidentified K channel (which appears independent of Ca 2+ oscillations or I ca /VOCC). UTP-gated signaling pathways triggered by activation of P2Y 4 R stimulate 5-HT release.
& Imagery; includes NWS alerts and warnings No 6 Wireless Emergency Alerts (WEA) Mobile Phone Alerts & Warnings only No 7 Interactive NWS (iNWS) - NOTE 1 https://inws.ncep.noaa.gov/ Mobile Phone $$$$) Internet/ Mobile Phone Alerts and Warnings No 15 County or Local Emergency Management Telephone alert
Eswara, Manoja B K; Clayton, Ashley; Mangroo, Dev
2012-12-01
Utp8p is an essential nucleolar protein that channels aminoacyl-tRNAs from aminoacyl-tRNA synthetases in the nucleolus to the nuclear tRNA export receptors located in the nucleoplasm and nuclear pore complex in Saccharomyces cerevisiae. Utp8p is also part of the U3 snoRNA-associated protein complex involved in 18S rRNA biogenesis in the nucleolus. We report that Utp22p, which is another member of the U3 snoRNA-associated protein complex, is also an intranuclear component of the nuclear tRNA export machinery. Depletion of Utp22p results in nuclear retention of mature tRNAs derived from intron-containing and intronless precursors. Moreover, Utp22p copurifies with the nuclear tRNA export receptor Los1p, the aminoacyl-tRNA synthetase Tys1p and Utp8p, but not with the RanGTPase Gsp1p and the nuclear tRNA export receptor Msn5p. Utp22p interacts directly with Utp8p and Los1p in a tRNA-independent manner in vitro. Utp22p also interacts directly with Tys1p, but this binding is stimulated when Tys1p is bound to tRNA. However, Utp22p, unlike Utp8p, does not bind tRNA saturably. These data suggest that Utp22p recruits Utp8p to aminoacyl-tRNA synthetases in the nucleolus to collect aminoacyl-tRNA and then accompanies the Utp8p-tRNA complex to deliver the aminoacyl-tRNAs to Los1p but not Msn5p. It is possible that Nrap/Nol6, the mammalian orthologue of Utp22p, plays a role in channelling aminoacyl-tRNA to the nuclear tRNA export receptor exportin-t.
NASA Astrophysics Data System (ADS)
Trzcinski, Peter; Karanassios, Vassili
2016-05-01
During the last several years, the world has moved from wired communications (e.g., a wired ethernet, wired telephone) to wireless communications (e.g., cell phones, smart phones, tablets). However, data acquisition has lagged behind and for the most part, data in laboratory settings are still acquired using wired communications (or even plug in boards). In this paper, approaches that can be used for wireless data acquisition are briefly discussed using a conceptual model of a future, mobile, portable micro-instrument as an example. In addition, past, present and near-future generations of communications are discussed; processors, operating systems and benchmarks are reviewed; networks that may be used for data acquisition in the field are examined; and, the possibility of connecting sensor or micro-instrument networks to the internet of things is postulated.
Utp9p facilitates Msn5p-mediated nuclear reexport of retrograded tRNAs in Saccharomyces cerevisiae.
Eswara, Manoja B K; McGuire, Andrew T; Pierce, Jacqueline B; Mangroo, Dev
2009-12-01
Utp9p is a nucleolar protein that is part of a subcomplex containing several U3 snoRNA-associated proteins including Utp8p, which is a protein that shuttles aminoacyl-tRNAs from the nucleolus to the nuclear tRNA export receptors Los1p and Msn5p in Saccharomyces cerevisiae. Here we show that Utp9p is also an intranuclear component of the Msn5p-mediated nuclear tRNA export pathway. Depletion of Utp9p caused nuclear accumulation of mature tRNAs derived from intron-containing precursors, but not tRNAs made from intronless pre-tRNAs. Utp9p binds tRNA directly and saturably, and copurifies with Utp8p, Gsp1p, and Msn5p, but not with Los1p or aminoacyl-tRNA synthetases. Utp9p interacts directly with Utp8p, Gsp1p, and Msn5p in vitro. Furthermore, Gsp1p forms a complex with Msn5p and Utp9p in a tRNA-dependent manner. However, Utp9p does not shuttle between the nucleus and the cytoplasm. Because tRNA splicing occurs in the cytoplasm and the spliced tRNAs are retrograded back to the nucleus, we propose that Utp9p facilitates nuclear reexport of retrograded tRNAs. Moreover, the data suggest that Utp9p together with Utp8p translocate aminoacyl-tRNAs from the nucleolus to Msn5p and assist with formation of the Msn5p-tRNA-Gsp1p-GTP export complex.
ERIC Educational Resources Information Center
Piedmo, Greg
1995-01-01
Integrated services digital network (ISDN) is a dial-up digital transmission service supporting transmission of audio, video, and text data over standard copper telephone wires or fiber optic cables. Advantages of ISDN over analog transmission include the ability of one phone line to support up to three simultaneous, separate conversations (phone,…
NASA Astrophysics Data System (ADS)
Chiou, Jin-Chern; Hung, Chen-Chun; Lin, Chun-Ying
2010-07-01
This work presents a MEMS-based image stabilizer applied for anti-shaking function in photographic cell phones. The proposed stabilizer is designed as a two-axis decoupling XY stage 1.4 × 1.4 × 0.1 mm3 in size, and adequately strong to suspend an image sensor for anti-shaking photographic function. This stabilizer is fabricated by complex fabrication processes, including inductively coupled plasma (ICP) processes and flip-chip bonding technique. Based on the special designs of a hollow handle layer and a corresponding wire-bonding assisted holder, electrical signals of the suspended image sensor can be successfully sent out with 32 signal springs without incurring damage during wire-bonding packaging. The longest calculated traveling distance of the stabilizer is 25 µm which is sufficient to resolve the anti-shaking problem in a three-megapixel image sensor. Accordingly, the applied voltage for the 25 µm moving distance is 38 V. Moreover, the resonant frequency of the actuating device with the image sensor is 1.123 kHz.
Lifelink: 3G-based mobile telemedicine system.
Alis, Christian; del Rosario, Carlos; Buenaobra, Bernardino; Mar Blanca, Carlo
2009-04-01
Current wired telemedicine systems encounter difficulties when implemented in archipelagic developing countries because of the high cost of fixed infrastructure. In this research, we devised Lifelink, a mobile real-time telemonitoring and diagnostic facility to command and control remote medical devices through mobile phones. The whole process is phone-based, effectively freeing offsite medical specialists from stationary monitoring consoles and endowing the system with the potential to increase the number participating consultants. The electrocardiogram (ECG) readings are analyzed using a detrended fluctuation technique and classified into pathological cases using an unassisted K-means clustering algorithm. We analyzed 30 batches of 2-hour ECG signals taken from cardiac patients (20 males, 10 females, mean age 46.7 years) with pre-diagnosed pathologies. The method successfully categorized the 30 subjects without user intervention into the following cases: normal (at 86.7% accuracy), congestive heart failure (86.7%), and atrial fibrillation (80.0%). The synergy of mobile monitoring and fluctuation analysis presents a powerful platform to reach remote, underserved communities with poor or nonexistent wired communication structures. It is likely to be essential in the development of new mobile diagnostic and prognostic measures.
Cellular phones and their hazards: the current evidence.
Munshi, Anusheel; Jalali, Rakesh
2002-01-01
The past decade has seen an exponential increase globally in the use of cellular phones (popularly known as mobile or cell phones). These phones are convenient and trendy. Discarding the wire means that the communication is through electromagnetic waves, which could have potential hazards. Alarmist reports in the lay press and high profile lawsuits, particularly in the West, have attracted attention to the possible harmful effects of cellular phones. Adverse effects investigated by various clinical trials include the possible link to increased risk of vehicular accidents, leukaemias, sleep disturbances and the more serious brain tumours. Available level II evidence suggests that the only proven side-effect is an increased risk of vehicular accidents. So far, all studies have consistently negated any association between cellular phones and brain tumours. Yet, the final word remains to be said.
1983-05-01
Firing data cards. PROCEDURES I. Prior to live fire exercises all firers must be oriented on range procedures. 2. Preparatory marksmanship training...Ordnance detail. 2. Range safety officer. 7. Medical personnel. 3. Firing line safety NCOs. 8. Control tower operators. i 4. Scorer (I per firer ). 9. Pit...phones and wire (for PIT commo). PROCEDURES I. Prior to live fire exercises, all firers must be oriented on range procedures. 2. Scorers are responsible
Li, Peng-Yun; Zeng, Xiao-Rong; Yang, Yan; Cai, Fang; Li, Miao-Ling; Liu, Zhi-Fei; Pei, Jie; Zhou, Wen
2008-02-25
The aim of the present study was to investigate the effects of inositol 1,4,5-trisphosphate (IP(3))-generating agonist UTP on spontaneous transient outward currents (STOCs), and explore the role of intracellular Ca(2+) release in the current response mediated by IP(3) in porcine coronary artery smooth muscle cells (CASMCs). The coronary artery was excised from the fresh porcine heart and cut into small segments (2 mm × 5 mm) and then transferred to enzymatic dissociation solution for incubation. Single CASMCs were obtained by two-step enzyme digestion at 37 °C. STOCs were recorded and characterized using the perforated whole-cell patch-clamp configuration in freshly isolated porcine CASMCs. The currents were amplified and filtered by patch-clamp amplifier (Axopatch 200B), and then the digitized data were recorded by pClamp 9.0 software and further analyzed by MiniAnalysis 6.0 program. The results were as follows: (1) UTP led to conspicuous increases in STOC amplitude by (57.54±5.34)% and in frequency by (77.46±8.42)% (P<0.01, n=38). (2) The specific blocker of phospholipase C (PLC) - U73122 (5 μmol/L) remarkably reduced STOC amplitude by (31.04±7.46)% and frequency by (41.65±16.59)%, respectively (P<0.05, n=10). In the presence of U73122, UTP failed to reactivate STOCs (n=7). (3) Verapamil (20 μmol/L) and CdCl2 (200 μmol/L), two blockers of L-type voltage-dependent Ca(2+) channels, had little effects on STOCs initiated by UTP (n=8). (4) 1 μmol/L bisindolylmaleimide I (BisI), a potent blocker of protein kinase C (PKC), significantly increased STOC amplitude by (65.44±24.66)% and frequency by (61.35±21.47)% (P<0.01, n=12); UTP (40 μmol/L), applied in the presence of 1 μmol/L BisI, could further increase STOC activity (P<0.05, P<0.01, n=12). Subsequent application of ryanodine (50 μmol/L) abolished STOC activity. (5) In the presence of UTP (40 μmol/L), inhibition of IP(3) receptors (IP(3)Rs) by 2-aminoethoxydiphenyl borate (2-APB, 40 μmol/L) reduced STOC amplitude by (24.08±3.97)% (P<0.05, n=8), but had little effect on STOC frequency (n=8). While application of 2-APB (80 μmol/L) significantly reduced STOC amplitude by (31.43±6.34)% and frequency by (40.59±19.01)%, respectively (P<0.05, P<0.01, n=6). Subsequent application of ryanodine (50 μmol/L) completely blocked STOC activity. Pretreatment of cells with 2-APB (40 μmol/L) or ryanodine (50 μmol/L), UTP (40 μmol/L) failed to reactivate STOCs. The results suggest that UTP activates STOCs mainly via PLC and IP(3)-dependent mechanisms. Complex Ca(2+)-mobilization pathways are involved in UTP-mediated STOC activation in porcine CASMCs.
Mühlmann-Díaz, M C; Dullea, R G; Bedford, J S
1996-07-01
We have utilized 5-bromo-2'deoxyuridine (BrdU) substituted DNA as a probe for a number of applications including, principally, for chromosome painting by fluorescence in situ hybridization (FISH) but also for DNA end-labeling to detect apoptotic cell death and for filter hybridization. Br-dUTP was used as a substitute for biotin or digoxigenin-dUTP in probe labeling techniques, such as random priming, nick translation, end-labeling or PCR. An especially useful application is that it may be incorporated into probe DNA while cells or plasmids in bacteria are growing in the presence of BrdU. This can be particularly advantageous when large quantities of probe are needed, since the cost per mole of digoxigenin-dUTP or biotin-dUTP is nearly 1000 times that of Br-dUTP. Also, if probe is prepared by growth in BrdU, the difference in cost to prepare equal quantities of labeled DNA is more than 10,000 times greater for biotin-dUTP.
Vats, M C; Singh, S K
2015-11-01
Demand for gold and silver has been escalating with increasing usage of electronic equipment globally. Around 267.3 MT of gold and 7275 MT of silver are being consumed annually for manufacturing mobile phones, laptops and other electronic equipment. However, only 15% is recuperated from these equipment; the remainder lies in the storage yards or landfills. The waste comprise glass, plastics, wires, batteries, PCBs, metal casing, etc. The PCB is composed of precious metals, which creates immense purpose for recycling and recovery. This paper characterises and assesses the recoverable metallic fraction of gold and silver from PCBs of mobile phones. The methodology is based on dismantling of the mobile handset and subjecting the PCBs to roasting and acid digestion. The digested samples were analysed by atomic absorption spectroscopy and the content of gold and silver in the PCBs was to be found in the range of 0.009-0.017% and 0.25-0.79% by weight respectively. Copyright © 2015 Elsevier Ltd. All rights reserved.
Pwp2 mediates UTP-B assembly via two structurally independent domains.
Boissier, Fanny; Schmidt, Christina Maria; Linnemann, Jan; Fribourg, Sébastien; Perez-Fernandez, Jorge
2017-06-09
The SSU processome constitutes a large ribonucleoprotein complex involved in the early steps of ribosome biogenesis. UTP-B is one of the first multi-subunit protein complexes that associates with the pre-ribosomal RNA to form the SSU processome. To understand the molecular basis of the hierarchical assembly of the SSU-processome, we have undergone a structural and functional analysis of the UTP-B subunit Pwp2p. We show that Pwp2p is required for the proper assembly of UTP-B and for a productive association of UTP-B with pre-rRNA. These two functions are mediated by two distinct structural domains. The N-terminal domain of Pwp2p folds into a tandem WD-repeat (tWD) that associates with Utp21p, Utp18p, and Utp6p to form a core complex. The CTDs of Pwp2p and Utp21p mediate the assembly of the heterodimer Utp12p:Utp13p that is required for the stable incorporation of the UTP-B complex in the SSU processome. Finally, we provide evidence suggesting a role of UTP-B as a platform for the binding of assembly factors during the maturation of 20S rRNA precursors.
hUTP24 is essential for processing of the human rRNA precursor at site A1, but not at site A0
Tomecki, Rafal; Labno, Anna; Drazkowska, Karolina; Cysewski, Dominik; Dziembowski, Andrzej
2015-01-01
Production of ribosomes relies on more than 200 accessory factors to ensure the proper sequence of steps and faultless assembly of ribonucleoprotein machinery. Among trans-acting factors are numerous enzymes, including ribonucleases responsible for processing the large rRNA precursor synthesized by RNA polymerase I that encompasses sequences corresponding to mature 18S, 5.8S, and 25/28S rRNA. In humans, the identity of most enzymes responsible for individual processing steps, including endoribonucleases that cleave pre-rRNA at specific sites within regions flanking and separating mature rRNA, remains largely unknown. Here, we investigated the role of hUTP24 in rRNA maturation in human cells. hUTP24 is a human homolog of the Saccharomyces cerevisiae putative PIN domain-containing endoribonuclease Utp24 (yUtp24), which was suggested to participate in the U3 snoRNA-dependent processing of yeast pre-rRNA at sites A0, A1, and A2. We demonstrate that hUTP24 interacts to some extent with proteins homologous to the components of the yeast small subunit (SSU) processome. Moreover, mutation in the putative catalytic site of hUTP24 results in slowed growth of cells and reduced metabolic activity. These effects are associated with a defect in biogenesis of the 40S ribosomal subunit, which results from decreased amounts of 18S rRNA as a consequence of inaccurate pre-rRNA processing at the 5′-end of the 18S rRNA segment (site A1). Interestingly, and in contrast to yeast, site A0 located upstream of A1 is efficiently processed upon UTP24 dysfunction. Finally, hUTP24 inactivation leads to aberrant processing of 18S rRNA 2 nucleotides downstream of the normal A1 cleavage site. PMID:26237581
NASA Astrophysics Data System (ADS)
Arce, J. L.; Gardner, J. E.; Macías, J. L.
2013-01-01
The Nevado de Toluca volcano in Central Mexico has been active over the last ca. 42 ka, during which tens of km3 of pyroclastic material were erupted and two important Plinian-type eruptions occurred at ca. 21.7 ka (Lower Toluca Pumice: LTP) and ca. 10.5 ka (Upper Toluca Pumice: UTP). Samples from both the LTP and UTP contain plagioclase, amphibole, iron-titanium oxides, and minor anhedral biotite, set in a vesicular, rhyolitic, glassy matrix. In addition, UTP dacites contain orthopyroxene. Analysis of melt inclusions in plagioclase phenocrysts yields H2O contents of 2-3.5 wt.% for LTP and 1.3-3.6 wt.% for UTP samples. Ilmenite-ulvospinel geothermometry yields an average temperature of ~ 868 °C for the LTP magma (hotter than the UTP magma, ~ 842 °C; Arce et al., 2006), whereas amphibole-plagioclase geothermometry yields a temperature of 825-859 °C for the LTP magma. Water-saturated experiments using LTP dacite suggest that: (i) amphibole is stable above 100 MPa and below 900 °C; (ii) plagioclase crystallizes below 250-100 MPa at temperatures of 850-900 °C; and (iii) pyroxene is stable only below pressures of 200-100 MPa and temperatures of 825-900 °C. Comparison of natural and experimental data suggests that the LTP dacitic magma was stored at 150-200 MPa (5.8-7.7 km below the volcano summit). No differences in pressure found between 21.7 ka and 10.5 ka suggest that these two magmas were stored at similar depths. Orthopyroxene produced in lower temperature LTP experiments is compositionally different to those found in UTP natural samples, suggesting that they originated in two different magma batches. Whole-rock chemistry, petrographic features, and mineral compositions suggest that magma mixing was responsible for the generation of the dacitic Plinian LTP eruption.
P2 purinoceptors regulate calcium-activated chloride and fluid transport in 31EG4 mammary epithelia.
Blaug, Sasha; Rymer, Jodi; Jalickee, Stephen; Miller, Sheldon S
2003-04-01
It has been reported that secretory mammary epithelial cells (MEC) release ATP, UTP, and UDP upon mechanical stimulation. Here we examined the physiological changes caused by ATP/UTP in nontransformed, clonal mouse mammary epithelia (31EG4 cells). In control conditions, transepithelial potential (apical side negative) and resistance were -4.4 +/- 1.3 mV (mean +/- SD, n = 12) and 517.7 +/- 39.4 Omega. cm(2), respectively. The apical membrane potential was -43.9 +/- 1.7 mV, and the ratio of apical to basolateral membrane resistance (R(A)/R(B)) was 3.5 +/- 0.2. Addition of ATP or UTP to the apical or basolateral membranes caused large voltage and resistance changes with an EC(50) of approximately 24 microM (apical) and approximately 30 microM (basal). Apical ATP/UTP (100 microM) depolarized apical membrane potential by 17.6 +/- 0.8 mV (n = 7) and decreased R(A)/R(B) by a factor of approximately 3. The addition of adenosine to either side (100 microM) had no effect on any of these parameters. The ATP/UTP responses were partially inhibited by DIDS and suramin and mediated by a transient increase in free intracellular Ca(2+) concentration (427 +/- 206 nM; 15-25 microM ATP, apical; n = 6). This Ca(2+) increase was blocked by cyclopiazonic acid, by BAPTA, or by xestospongin C. 31EG4 MEC monolayers also secreted or absorbed fluid in the resting state, and ATP or UTP increased fluid secretion by 5.6 +/- 3 microl x cm(-2) x h(-1) (n = 10). Pharmacology experiments indicate that 31EG4 epithelia contain P2Y(2) purinoceptors on the apical and basolateral membranes, which upon activation stimulate apical Ca(2+)-dependent Cl channels and cause fluid secretion across the monolayer. This suggests that extracellular nucleotides could play a fundamental role in mammary gland paracrine signaling and the regulation of milk composition in vivo.
Soviet Naval Special Purpose Forces: Origins and Operations in World War II
1989-12-01
amphibious aircraft onto a lake, from which they walked into the area between Nikel and Luostari and back out again. Their journey lasted ten days and...moved up into the snow-covered hills, and after some hours of movement, followed a tele- phone wire to a German guard post. Without carefully observing...telephone wire in rolls. They moved all the captured materiel to shore, and then to their base. The detachment now had enemy guns and ammunition for use
Pharmacological characterization of nucleotide P2Y receptors on endothelial cells of the mouse aorta
Guns, Pieter-Jan D F; Korda, András; Crauwels, Herta M; Van Assche, Tim; Robaye, Bernard; Boeynaems, Jean-Marie; Bult, Hidde
2005-01-01
Nucleotides regulate various effects including vascular tone. This study was aimed to characterize P2Y receptors on endothelial cells of the aorta of C57BL6 mice. Five adjacent segments (width 2 mm) of the thoracic aorta were mounted in organ baths to measure isometric force development. Nucleotides evoked complete (adenosine 5′ triphosphate (ATP), uridine 5′ triphosphate (UTP), uridine 5′ diphosphate (UDP); >90%) or partial (adenosine 5′ diphosphate (ADP)) relaxation of phenylephrine precontracted thoracic aortic rings of C57BL6 mice. Relaxation was abolished by removal of the endothelium and was strongly suppressed (>90%) by inhibitors of nitric oxide synthesis. The rank order of potency was: UDP∼UTP∼ADP>adenosine 5′-[γ-thio] triphosphate (ATPγS)>ATP, with respective pD2 values of 6.31, 6.24, 6.22, 5.82 and 5.40. These results are compatible with the presence of P2Y1 (ADP>ATP), P2Y2 or P2Y4 (ATP and UTP) and P2Y6 (UDP) receptors. P2Y4 receptors were not involved, since P2Y4-deficient mice displayed unaltered responses to ATP and UTP. The purinergic receptor antagonist suramin exerted surmountable antagonism for all agonists. Its apparent pKb for ATP (4.53±0.07) was compatible with literature, but the pKb for UTP (5.19±0.03) was significantly higher. This discrepancy suggests that UTP activates supplementary non-P2Y2 receptor subtype(s). Further, pyridoxal-phosphate-6-azophenyl-2′-4′-disulphonic acid (PPADS) showed surmountable (UTP, UDP), nonsurmountable (ADP) or no antagonism (ATP). Finally, 2′-deoxy-N6-methyladenosine3′,5′-bisphosphate (MRS2179) inhibited ADP-evoked relaxation only. Taken together, these results point to the presence of functional P2Y1 (ADP), P2Y2 (ATP, UTP) and P2Y6 (UDP) receptors on murine aorta endothelial cells. The identity of the receptor(s) mediating the action of UTP is not fully clear and other P2Y subtypes might be involved in UTP-evoked vasodilatation. PMID:15997227
ERIC Educational Resources Information Center
Tech Directions, 2011
2011-01-01
One of the hottest areas in technology is invisible. Wireless communications allow people to transmit voice messages, data, and other signals through the air without physically connecting senders to receivers with cables or wires. And the technology is spreading at lightning speed. Cellular phones, personal digital assistants, and wireless…
Martiañez, Tania; Segura, Mònica; Figueiro-Silva, Joana; Grijota-Martinez, Carmen; Trullas, Ramón; Casals, Núria
2014-01-01
In response to peripheral nerve injury, Schwann cells adopt a migratory phenotype and modify the extracellular matrix to make it permissive for cell migration and axonal re-growth. Uridine 5′-triphosphate (UTP) and other nucleotides are released during nerve injury and activate purinergic receptors expressed on the Schwann cell surface, but little is known about the involvement of purine signalling in wound healing. We studied the effect of UTP on Schwannoma cell migration and wound closure and the intracellular signaling pathways involved. We found that UTP treatment induced Schwannoma cell migration through activation of P2Y2 receptors and through the increase of extracellular matrix metalloproteinase-2 (MMP-2) activation and expression. Knockdown P2Y2 receptor or MMP-2 expression greatly reduced wound closure and MMP-2 activation induced by UTP. MMP-2 activation evoked by injury or UTP was also mediated by phosphorylation of all 3 major mitogen-activated protein kinases (MAPKs): JNK, ERK1/2, and p38. Inhibition of these MAPK pathways decreased both MMP-2 activation and cell migration. Interestingly, MAPK phosphorylation evoked by UTP exhibited a biphasic pattern, with an early transient phosphorylation 5 min after treatment, and a late and sustained phosphorylation that appeared at 6 h and lasted up to 24 h. Inhibition of MMP-2 activity selectively blocked the late, but not the transient, phase of MAPK activation. These results suggest that MMP-2 activation and late MAPK phosphorylation are part of a positive feedback mechanism to maintain the migratory phenotype for wound healing. In conclusion, our findings show that treatment with UTP stimulates in vitro Schwannoma cell migration and wound repair through a MMP-2-dependent mechanism via P2Y2 receptors and MAPK pathway activation. PMID:24905332
Redmayne, Mary; Smith, Euan; Abramson, Michael J
2013-10-22
The exposure of young people to radiofrequency electromagnetic fields (RF-EMFs) has increased rapidly in recent years with their increased use of cellphones and use of cordless phones and WiFi. We sought to ascertain associations between New Zealand early-adolescents' subjective well-being and self-reported use of, or exposure to, wireless telephone and internet technology. In this cross-sectional survey, participants completed questionnaires in class about their cellphone and cordless phone use, their self-reported well-being, and possible confounding information such as whether they had had influenza recently or had a television in the bedroom. Parental questionnaires provided data on whether they had WiFi at home and cordless phone ownership and model. Data were analysed with Ordinal Logistic Regression adjusting for common confounders. Odds ratios (OR) and 95% confidence intervals were calculated. The number and duration of cellphone and cordless phone calls were associated with increased risk of headaches (>6 cellphone calls over 10 minutes weekly, adjusted OR 2.4, CI 1.2-4.8; >15 minutes cordless use daily adjusted OR 1.74, CI 1.1-2.9)). Texting and extended use of wireless phones was related to having a painful 'texting' thumb). Using a wired cellphone headset was associated with tinnitus (adjusted OR 1.8, CI 1.0-3.3), while wireless headsets were associated with headache (adjusted OR 2.2, CI 1.1-4.5), feeling down/depressed (adjusted OR 2.0, CI 1.1-3.8), and waking in the night (adjusted OR 2.4, CI 1.2-4.8). Several cordless phone frequencies bands were related to tinnitus, feeling down/depressed and sleepiness at school, while the last of these was also related to modulation. Waking nightly was less likely for those with WiFi at home (adjusted OR 0.7, CI 0.4-0.99). Being woken at night by a cellphone was strongly related to tiredness at school (OR 3.49, CI 1.97-6.2). There were more statistically significant associations (36%) than could be expected by chance (5%). Several were dose-dependent relationships. To safeguard young people's well-being, we suggest limiting their use of cellphones and cordless phones to less than 15 minutes daily, and employing a speaker-phone device for longer daily use. We recommend parental measures are taken to prevent young people being woken by their cellphones.
2013-01-01
Background The exposure of young people to radiofrequency electromagnetic fields (RF-EMFs) has increased rapidly in recent years with their increased use of cellphones and use of cordless phones and WiFi. We sought to ascertain associations between New Zealand early-adolescents’ subjective well-being and self-reported use of, or exposure to, wireless telephone and internet technology. Methods In this cross-sectional survey, participants completed questionnaires in class about their cellphone and cordless phone use, their self-reported well-being, and possible confounding information such as whether they had had influenza recently or had a television in the bedroom. Parental questionnaires provided data on whether they had WiFi at home and cordless phone ownership and model. Data were analysed with Ordinal Logistic Regression adjusting for common confounders. Odds ratios (OR) and 95% confidence intervals were calculated. Results The number and duration of cellphone and cordless phone calls were associated with increased risk of headaches (>6 cellphone calls over 10 minutes weekly, adjusted OR 2.4, CI 1.2-4.8; >15 minutes cordless use daily adjusted OR 1.74, CI 1.1-2.9)). Texting and extended use of wireless phones was related to having a painful ‘texting’ thumb). Using a wired cellphone headset was associated with tinnitus (adjusted OR 1.8, CI 1.0-3.3), while wireless headsets were associated with headache (adjusted OR 2.2, CI 1.1-4.5), feeling down/depressed (adjusted OR 2.0, CI 1.1-3.8), and waking in the night (adjusted OR 2.4, CI 1.2-4.8). Several cordless phone frequencies bands were related to tinnitus, feeling down/depressed and sleepiness at school, while the last of these was also related to modulation. Waking nightly was less likely for those with WiFi at home (adjusted OR 0.7, CI 0.4-0.99). Being woken at night by a cellphone was strongly related to tiredness at school (OR 3.49, CI 1.97-6.2). Conclusions There were more statistically significant associations (36%) than could be expected by chance (5%). Several were dose-dependent relationships. To safeguard young people’s well-being, we suggest limiting their use of cellphones and cordless phones to less than 15 minutes daily, and employing a speaker-phone device for longer daily use. We recommend parental measures are taken to prevent young people being woken by their cellphones. PMID:24148357
Planning for Technology: An Administrator's Guide to the Next Century.
ERIC Educational Resources Information Center
Day, William C.
1998-01-01
Discusses ways for preparing schools for integrating technology, including designing the wiring infrastructure, equipment purchases, furniture needs, and ergonomic considerations. Describes four levels of Internet connectivity access and provides a list of contact names, phone numbers, and Web sites for technology fund information from each state.…
ERIC Educational Resources Information Center
Chretien, Wendy
2007-01-01
The residential services group is lobbying to dump its aging hard-wired phone system because students don't use it. The town and campus public safety officials are demanding that their portable two-way radios operate well not only outdoors, but within campus buildings. Students are now expecting text messaging and WiFi service to work everywhere…
Endothelium-dependent relaxation evoked by ATP and UTP in the aorta of P2Y2-deficient mice
Guns, Pieter-Jan D F; Van Assche, Tim; Fransen, Paul; Robaye, Bernard; Boeynaems, Jean-Marie; Bult, Hidde
2006-01-01
Based on pharmacological criteria, we previously suggested that in the mouse aorta, endothelium-dependent relaxation by nucleotides is mediated by P2Y1 (adenosine diphosphate (ADP)), P2Y2 (adenosine triphosphate (ATP)) and P2Y6 (uridine diphosphate (UDP)) receptors. For UTP, it was unclear whether P2Y2, P2Y6 or yet another subtype was involved. Therefore, in view of the lack of selective purinergic agonists and antagonists, we used P2Y2-deficient mice to clarify the action of UTP. Thoracic aorta segments (width 2 mm) of P2Y2-deficient and wild-type (WT) mice were mounted in organ baths to measure isometric force development and intracellular calcium signalling. Relaxations evoked by ADP, UDP and acetylcholine were identical in knockout and WT mice, indicating that the receptors for these agonists function normally. P2Y2-deficient mice showed impaired ATP- and adenosine 5′[γ-thio] triphosphate (ATPγS)-evoked relaxation, suggesting that in WT mice, ATP and ATPγS activate predominantly the P2Y2 subtype. The ATP/ATPγS-evoked relaxation and calcium signals in the knockout mice were partially rescued by P2Y1, as they were sensitive to 2′-deoxy-N6-methyladenosine 3′,5′-bisphosphate (MRS2179), a P2Y1-selective antagonist. In contrast to ATP, the UTP-evoked relaxation was not different between knockout and WT mice. Moreover, the action of UTP was not sensitive to MRS2179. Therefore, the action of UTP is probably mediated mainly by a P2Y6(like) receptor subtype. In conclusion, we demonstrated that ATP-evoked relaxation of the murine aorta is mainly mediated by P2Y2. But this P2Y2 receptor has apparently no major role in UTP-evoked relaxation. The vasodilator effect of UTP is probably mediated mainly by a P2Y6(like) receptor. PMID:16415908
Some pharmacological properties of uridine nucleotides
Smith, M. W.
1964-01-01
Uridine di-, tri- and monophosphates (UDP, UTP and UMP) contracted the goldfish intestine preparation in that order of decreasing potency. Adenosine triphosphate (ATP) sensitized the gut to UTP and UDP but not to UMP. The fluoro-derivatives of UMP and UTP behaved like the unsubstituted nucleotides on the goldfish intestine but the main effect of 6-azaUDP and large amounts of uracil and uridine was to cause a relaxation. Structure-action relationships are discussed on the basis of these findings. UDPglucose and UDPacetylglucosamine each contracted the goldfish intestine but they were 500-times less active than UDP. Other smooth muscle preparations (tortoise jejunum, rat uterus, guinea-pig ileum and the fowl rectal caecum) contracted to UTP and UDP, but large amounts were needed. The cardiovascular effects in rats of UMP, UDP and UTP were complex and mediated mainly through an action on the peripheral blood vessels. In rats treated with phenoxybenzamine, UMP raised the blood pressure while UDP and UTP first lowered then raised the blood pressure. The fall in blood pressure was not abolished by pronethalol or atropine. The uridine phosphates affected the rat isolated heart only under hypoxic conditions. UTP and UDP dilated the blood vessels of the rabbit ear and UTP was six-times more effective than ATP. UTP and UDP were equiactive in increasing the force of beat of the frog isolated heart. UMP also had an effect if large amounts were given. PMID:14190461
1989-10-03
Georgia. TESTED 8y CHEcKED BY REPORTED BY, C PHONE 0 WIRE *GVJ DE SAMPLED BY OATE : SAO FORM IS$ Page of 20 24 OCT So Previous editions of this fore are...block for bto; line system. Cos- - $514.00 PO)8 - Second Stage Dike VE - Mod D Change in design for portion of 2nd stage cofferdike near tie-in with...ATION (Coordinteat~ Station)N14; _______________________________________12. MANUFACTURER’S DESIGNATION OF DRILL. 3. DRILLING AGENCY d~l gjr GvA.IIw1
The Effect of Internet Usage on Technology Comprehension of Physics Students: A Case Study
ERIC Educational Resources Information Center
Guzel, Hatice
2011-01-01
Rapid technological enhancements and changes necessitate people who can understand the relation between science and technology and perceive as well as comment on technological enhancements. The aim of the present study was to determine physics students comprehension of the operation principles of wired telephone, mobile phone, and latest medical…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-21
... things, the telephone services provided by third-party carriers to the Exchange were still not fully... intermittent phone and internet service. Specifically, the wired telephone lines and internet connections for... and Internet issues. \\6\\ See Securities Exchange Act Release No. 68161 (Nov. 5, 2012), 77 FR 67704...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-28
... not yet fully operational. Among other things, the telephone services provided by third-party carriers... the temporary suspension was needed because of the ongoing intermittent phone and internet service. Specifically, the wired telephone lines and internet connections for Floor brokers continued to not be...
Nörenberg, W; von Kügelgen, I; Meyer, A; Illes, P; Starke, K
2000-01-01
Cultured sympathetic neurones are depolarized and release noradrenaline in response to extracellular ATP, UDP and UTP. We examined the possibility that, in neurones cultured from rat thoracolumbar sympathetic ganglia, inhibition of the M-type potassium current might underlie the effects of UDP and UTP. Reverse transcriptase-polymerase chain reaction indicated that the cultured cells contained mRNA for P2Y2-, P2Y4- and P2Y6-receptors as well as for the KCNQ2- and KCNQ3-subunits which have been suggested to assemble into M-channels. In cultures of neurones taken from newborn as well as from 10 day-old rats, oxotremorine, the M-channel blocker Ba2+ and UDP all released previously stored [3H]-noradrenaline. The neurones possessed M-currents, the kinetic properties of which were similar in neurones from newborn and 9–12 day-old rats. UDP, UTP and ATP had no effect on M-currents in neurones prepared from newborn rats. Oxotremorine and Ba2+ substantially inhibited the current. ATP also had no effect on the M-current in neurones prepared from 9–12 day-old rats. Oxotremorine and Ba2+ again caused marked inhibition. In contrast to cultures from newborn animals, UDP and UTP attenuated the M-current in neurones from 9–12 day-old rats; however, the maximal inhibition was less than 30%. The results indicate that inhibition of the M-current is not involved in uracil nucleotide-induced transmitter release from rat cultured sympathetic neurones during early development. M-current inhibition may contribute to release at later stages, but only to a minor extent. The mechanism leading to noradrenaline release by UDP and UTP remains unknown. PMID:10683196
Zulewska, Justyna; Barbano, David M
2014-05-01
Raw milk (about 500 kg) was cold (4°C) separated and then the skim milk was pasteurized at 72°C and a holding time of 16s. The milk was cooled to 4°C and stored at ≤ 4°C until processing. The skim milk was microfiltered using a pilot-scale ceramic graded permeability (GP) microfilter system equipped with 0.1-µm nominal pore diameter ceramic Membralox membranes. First, about 155 kg of pasteurized skim milk was flushed through the system to push the water out of the system. Then, additional pasteurized skim milk (about 320 kg) was microfiltered (stage 1) in a continuous feed-and-bleed 3× process using the same membranes. The retentate from stage 1 was diluted with pasteurized reverse osmosis water in a 1:2 ratio and microfiltered (stage 2) with a GP system. This was repeated 3 times, with total of 3 stages in the process (stage 1 = microfiltration; stages 2 and 3 = diafiltration). The results from first 3 stages of the experiment were compared with previous data when processing skim milk at 50°C using ceramic uniform transmembrane pressure (UTP) membranes. Microfiltration of skim milk using ceramic UTP and GP membranes resulted in similar final retentate in terms of serum proteins (SP) removed. The SP removal rate (expressed by kilogram of SP removed per meter-squared of membrane area) was higher for GP membranes for each stage compared with UTP membranes. A higher passage of SP and SP removal rate for GP than UTP membranes was achieved by using a higher cross-flow velocity when processing skim milk. Increasing flux in subsequent stages did not affect membrane permeability and fouling. We operated under conditions that produced partial membrane fouling, due to using a flux that was less than limiting flux but higher than critical flux. Because the critical flux is a function of the cross-flow velocity, the difference in critical flux between UTP and GP membranes resulted only from operating under different cross-flow velocities (6.6 vs 7.12 for UTP and GP membranes, respectively). Conditions that allow microfiltration operation at higher flux will reduce the membrane surface area required to process the same amount of milk in the same length of time. Less membrane surface area reduces investment costs and uses less energy, water, and chemicals to clean the microfiltration system. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Control of apical membrane chloride permeability in the renal A6 cell line by nucleotides
Banderali, U; Brochiero, E; Lindenthal, S; Raschi, C; Bogliolo, S; Ehrenfeld, J
1999-01-01
The effect of extracellular nucleotides applied on the apical side of polarised A6 cells grown on permeant filters was investigated by measuring the changes in (i) the 36Cl efflux through the apical membranes, (ii) the intracellular chloride concentrations (aCli, measured with N-(6-methoxyquinolyl) acetoethyl ester, MQAE), (iii) ICl, the short-circuit current in the absence of Na+ transport and (iv) the characteristics of the apical chloride channels using a patch-clamp approach. ATP or UTP (0.1-500 μm) transiently stimulated ICl. The sequence of purinergic agonist potencies was UTP = ATP > ADP >> the P2X-selective agonist β,γ-methylene ATP = the P2Y-selective agonist 2-methylthioATP. Suramin (100 μm) as the P2Y antagonist Reactive Blue 2 (10 μm) had no effect on the UTP (or ATP)-stimulated current. These findings are consistent with the presence of P2Y2-like receptors located on the apical membranes of A6 cells. Apical application of adenosine also transiently increased ICl. This effect was blocked by theophylline while the UTP-stimulated ICl was not. The existence of a second receptor, of the P1 type is proposed. ATP (or UTP)-stimulated ICl was blocked by apical application of 200 μmN-phenylanthranilic acid (DPC) or 100 μm niflumic acid while 100 μm glibenclamide was ineffective. Ionomycin and thapsigargin both transiently stimulated ICl; the nucleotide stimulation of ICl was not suppressed by pre-treatment with these agents. Chlorpromazin (50 μm), a Ca2+-calmodulin inhibitor strongly inhibited the stimulation of ICl induced either by apical UTP or by ionomycin application. BAPTA-AM pre-treatment of A6 cells blocked the UTP-stimulated ICl. Niflumic acid also blocked the ionomycin stimulated ICl. A fourfold increase in 36Cl effluxes through the apical membranes was observed after ATP or UTP application. These increases of the apical chloride permeability could also be observed when following aCli changes. Apical application of DPC (1 mm) or 5-nitro-2(3-phenylpropylamino)benzoic acid (NPPB; 500 μm) produced an incomplete inhibition of 36Cl effluxes through the apical membranes in ATP-stimulated and in untreated monolayers. In single channel patch-clamp experiments, an apical chloride channel with a unitary single channel conductance of 7.3 ± 0.6 pS (n = 12) was usually observed. ATP application induced the activation of one or more of these channels within a few minutes. These results indicate that multiple purinergic receptor subtypes are present in the apical membranes of A6 cells and that nucleotides can act as modulators of Cl− secretion in renal cells. PMID:10457087
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Gang; Olson, J.C.; Pu, R.
1995-10-01
Serological assays are routinely used in the laboratory diagnosis of human immunodeficiency virus type-1 (HrV-1) infection, but the polymerase chain reaction (PCR) is ultimately the most sensitive and direct method for establishing definitive diagnosis. As an alternative to the conventional radioactive PCR procedure we have developed and evaluated a pair of rapid nonradioisotopic flow cytometric detection methods. Using heminested PCR we directly incorporated fluorescein-12-dUTP (fluo-dUTP) or digoxigenin-11-dUTP (dig-dUTP) into the PCR-amplicons. The labeled amplicons were hybridized with biotinylated antisense and sense probes, followed by capture of the hybrid DNA using streptavidin-coated beads which were finally analyzed in a flow cytometermore » by (1) direct detection of the fluorescence intensity of the amplicons incorporating fluo-dUTP and (2) immunodetection of the amplicons incorporating dig-dUTP by anti-digoxigenin IgG labeled with fluorescein isothiocyanate (FITC). Although both assays were functionally comparable with radiolabeled probe in reliably detecting as low as five copies of HIV-1 proviral DNA sequences, the immunodetection of dig-dUTP consistently yielded higher mean channel fluorescence and gave a stable signal over an extended period of 12-14 weeks. In testing a panel of 20 pedigreed PBMC specimens from blood donors with or without HIV-1 infection, the results of both flow cytometric assays were identical with those of the conventional radioactive procedure. Therefore, we conclude that the dig-dUTP incorporation in amplicons, hybridization with a pair of sense-antisense biotinylated probes and immunodetection of hybrids by flow cytometric analyses is the nonisotopic method of choice for PCR-diagnosis of HIV-1 infection. 21 refs., 2 figs., 4 tabs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ashley, G.W.; Harris, G.; Stubbe, J.A.
1988-06-14
The ribonucleoside triphosphate reductase (RTPR) of Lactobacillus leichmannii is inactivated by the substrate analogue 2'-chloro-2'-deoxyuridine 5'-triphosphate (ClUTP). Inactivation is due to alkylation by 2-methylene-3(2H)-furanone, a decomposition product of the enzymic product 3'-keto-2'-deoxyuridine triphosphate. The former has been unambiguously identified as 2-((ethylthio)methyl)-3(2H)-furanone, an ethanethiol trapped adduct, which is identical by /sup 1/H NMR spectroscopy with material synthesized chemically. Subsequent to rapid inactivation, a slow process occurs that results in formation of a new protein-associated chromophore absorbing maximally near 320 nm. The terminal stages of the inactivation have now been investigated in detail. The alkylation and inactivation stoichiometries were studied as amore » function of the ratio of ClUTP to enzyme. The amount of labeling of RTPR increased with increasing ClUTP concentration up to the maximum of approximately 4 labels/RTPR, yet the degree of inactivation did not increase proportionally. This suggests that (1) RTPR may be inactivated by alkylation of a single site and (2) decomposition of 3'-keto-dUTP is not necessarily enzyme catalyzed. The formation of the new protein chromophore was also monitored during inactivation and found to reach its full extent upon the first alkylation . Thus, out of four alkylation sites, only one appears capable of undergoing the subsequent reaction to form the new chromophore. Model studies suggest that the new chromophore is due to addition of an amino group to the 5-position of enzyme-bound furanone, followed by ring opening and tautomerization to give a ..beta..-aminoenone structure.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-16
... (``Restricted Market Maker'') in a derivative securities product (``UTP Derivative Security'') that derives its... in a UTP Derivative Security on the Exchange is prohibited from acting or registering as a Market Maker on any other exchange in any Reference Asset of that UTP Derivative Security, or any derivative...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-16
... securities product (``UTP Derivative Security'') that derives its value from one or more currencies or..., proposed EDGA Rule 14.1(c)(5)(A) provides that a Restricted Market Maker in a UTP Derivative Security on... Reference Asset of that UTP Derivative Security, or any derivative instrument based on a Reference Asset of...
ERIC Educational Resources Information Center
Collins, Allan; Halverson, Richard
2009-01-01
The digital revolution has hit education, with more and more classrooms plugged into the whole wired world. But are schools making the most of new technologies? Are they tapping into the learning potential of today's Firefox/Facebook/cell phone generation? Have schools fallen through the crack of the digital divide? In "Rethinking Education in the…
2012-01-01
NUMBER activates BDNF expression in mouse brain 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Pizarro, JM, Chang, WE, Bah, MJ...of the Organophosphorus Compound VX Activates BDNF Expression in Mouse Brain Jose M. Pizarro,*,† Wenling E. Chang,†,‡ Mariama J. Bah,† Linnzi K. M...triphosphate and UTP, and 2 ll modified cytidine triphosphate solution [2mM]), 33P-UTP (specific activity of 5 3 109 cpm/lg), 2 ll RNA polymerase, 2 ll of
1990-09-30
UTP 620344220 30 September 1990 Command Line form gfl MSG: Estructure closed apIcatic Figure 5-64b (AFTER) 5-132 UTP 620344220 30 September 1990 Command...620344220 30 September 1990 Comman Lineay form gf 1 MSG: Estructure 9 psted on workstation 1 at priority 1 applcatioo Figure 5-101a (BEFORE) 5-205 UTP
Hedendahl, Lena K; Carlberg, Michael; Koppel, Tarmo; Hardell, Lennart
2017-01-01
Wireless access to the Internet is now commonly used in schools. Many schools give each student their own laptop and utilize the laptops and wireless fidelity (Wi-Fi) connection for educational purposes. Most children also bring their own mobile phones to school. Since children are obliged by law to attend school, a safe environment is important. Lately, it has been discussed if radiofrequency (RF) radiation can have long-term adverse effects on children's health. This study conducted exposimetric measurements in schools to assess RF emissions in the classroom by measuring the teachers' RF exposure in order to approximate the children's exposure. Teachers in grades 7-12 carried a body-borne exposimeter, EME-Spy 200, in school during 1-4 days of work. The exposimeter can measure 20 different frequency bands from 87 to 5,850 MHz. Eighteen teachers from seven schools participated. The mean exposure to RF radiation ranged from 1.1 to 66.1 µW/m 2 . The highest mean level, 396.6 µW/m 2 , occurred during 5 min of a lesson when the teacher let the students stream and watch YouTube videos. Maximum peaks went up to 82,857 µW/m 2 from mobile phone uplink. Our measurements are in line with recent exposure studies in schools in other countries. The exposure levels varied between the different Wi-Fi systems, and if the students were allowed to use their own smartphones on the school's Wi-Fi network or if they were connected to GSM/3G/4G base stations outside the school. An access point over the teacher's head gave higher exposure compared with a school with a wired Internet connection for the teacher in the classroom. All values were far below International Commission on Non-Ionizing Radiation Protection's reference values, but most mean levels measured were above the precautionary target level of 3-6 µW/m 2 as proposed by the Bioinitiative Report. The length of time wireless devices are used is an essential determinant in overall exposure. Measures to minimize children's exposure to RF radiation in school would include preferring wired connections, allowing laptops, tablets and mobile phones only in flight mode and deactivating Wi-Fi access points, when not used for learning purposes.
Kam, Wendy R.; Liu, Yang; Ding, Juan; Sullivan, David A.
2016-01-01
Purpose Researchers have hypothesized that treatment with cyclosporine A (CyA), interleukin-1 receptor antagonists (IL-1RA; e.g., anakinra), P2Y2 receptor agonists (e.g., uridine triphosphate; UTP), and rebamipide may alleviate human meibomian gland dysfunction (MGD) and/or dry eye disease. Investigators have also proposed that prostaglandin analogues (e.g., bimatoprost) may induce MGD. Our goal was to determine whether these compounds directly influence human meibomian gland epithelial cell (HMGEC) function. Methods Multiple concentrations of each compound were tested for effects on immortalized (I) HMGEC morphology and survival. Nontoxic dosages were used for our studies. Immortalized HMGEC were cultured in the presence of vehicle, CyA, IL-1RA, UTP, rebamipide, or bimatoprost for up to 6 days in various media. Experiments included positive controls for proliferation (epidermal growth factor and bovine pituitary extract), differentiation (azithromycin), and signaling pathway activation (insulin-like growth factor 1). Cells were analyzed for neutral lipid staining, lysosome accumulation, lipid composition, and phosphatidylinositol-3-kinase/Akt (AKT), phosphorylation. Results Our findings demonstrate that CyA, IL-1RA, UTP, rebamipide, and bimatoprost had no effect on the proliferation; neutral lipid content; lysosome number; or levels of free cholesterol, triglycerides, or phospholipids in IHMGECs. Cylosporine A, IL-1RA, rebamipide, and bimatoprost significantly reduced the phosphorylation of AKT, as compared to control. Of interest, tested doses of CyA above 8 nM killed the IHMGECs. Conclusions Our results show that CyA, IL-1RA, UTP, rebamipide, and bimatoprost do not influence the proliferation or differentiation of IHMGEC. However, with the exception of UTP, these compounds do decrease the activity of the AKT signaling pathway, which is known to promote cell survival. PMID:27552406
Kam, Wendy R; Liu, Yang; Ding, Juan; Sullivan, David A
2016-08-01
Researchers have hypothesized that treatment with cyclosporine A (CyA), interleukin-1 receptor antagonists (IL-1RA; e.g., anakinra), P2Y2 receptor agonists (e.g., uridine triphosphate; UTP), and rebamipide may alleviate human meibomian gland dysfunction (MGD) and/or dry eye disease. Investigators have also proposed that prostaglandin analogues (e.g., bimatoprost) may induce MGD. Our goal was to determine whether these compounds directly influence human meibomian gland epithelial cell (HMGEC) function. Multiple concentrations of each compound were tested for effects on immortalized (I) HMGEC morphology and survival. Nontoxic dosages were used for our studies. Immortalized HMGEC were cultured in the presence of vehicle, CyA, IL-1RA, UTP, rebamipide, or bimatoprost for up to 6 days in various media. Experiments included positive controls for proliferation (epidermal growth factor and bovine pituitary extract), differentiation (azithromycin), and signaling pathway activation (insulin-like growth factor 1). Cells were analyzed for neutral lipid staining, lysosome accumulation, lipid composition, and phosphatidylinositol-3-kinase/Akt (AKT), phosphorylation. Our findings demonstrate that CyA, IL-1RA, UTP, rebamipide, and bimatoprost had no effect on the proliferation; neutral lipid content; lysosome number; or levels of free cholesterol, triglycerides, or phospholipids in IHMGECs. Cylosporine A, IL-1RA, rebamipide, and bimatoprost significantly reduced the phosphorylation of AKT, as compared to control. Of interest, tested doses of CyA above 8 nM killed the IHMGECs. Our results show that CyA, IL-1RA, UTP, rebamipide, and bimatoprost do not influence the proliferation or differentiation of IHMGEC. However, with the exception of UTP, these compounds do decrease the activity of the AKT signaling pathway, which is known to promote cell survival.
Peters, Godefridus J
2018-05-03
The pyrimidine de novo nucleotide synthesis consists of 6 sequential steps. Various inhibitors against these enzymes have been developed and evaluated in the clinic for their potential anticancer activity: acivicin inhibits carbamoyl-phosphate-synthase-II, N-(phosphonacetyl)-L- aspartate (PALA) inhibits aspartate-transcarbamylase, Brequinar sodium and dichloroallyl-lawsone (DCL) inhibit dihydroorotate-dehydrogenase, and pyrazofurin (PF) inhibits orotate-phosphoribosyltransferase. We compared their growth inhibition against 3 cell lines from head-and-neck-cancer (HEP-2, UMSCC-14B and UMSCC-14C) and related the sensitivity to their effects on nucleotide pools. In all cell lines Brequinar and PF were the most active compounds with IC50 (50% growth inhibition) values between 0.06-0.37 µM, Acivicin was as potent (IC50s 0.26-1 µM), but DCL was 20-31-fold less active. PALA was most inactive (24-128 µM). At equitoxic concentrations, all pure antipyrimidine de novo inhibitors depleted UTP and CTP after 24 hr exposure, which was most pronounced for Brequinar (between 6-10% of UTP left, and 12-36% CTP), followed by DCL and PF, which were almost similar (6-16% UTP and 12-27% CTP), while PALA was the least active compound (10-70% UTP and 13-68% CTP). Acivicin is a multi-target inhibitor of more glutamine requiring enzymes (including GMP synthetase) and no decrease of UTP was found, but a pronounced decrease in GTP (31-72% left). In conclusion, these 5 inhibitors of the pyrimidine de novo nucleotide synthesis varied considerably in their efficacy and effect on pyrimidine nucleotide pools. Inhibitors of DHO-DH were most effective suggesting a primary role of this enzyme in controlling pyrimidine nucleotide pools.
UTP and Temporal Logic Model Checking
NASA Astrophysics Data System (ADS)
Anderson, Hugh; Ciobanu, Gabriel; Freitas, Leo
In this paper we give an additional perspective to the formal verification of programs through temporal logic model checking, which uses Hoare and He Unifying Theories of Programming (UTP). Our perspective emphasizes the use of UTP designs, an alphabetised relational calculus expressed as a pre/post condition pair of relations, to verify state or temporal assertions about programs. The temporal model checking relation is derived from a satisfaction relation between the model and its properties. The contribution of this paper is that it shows a UTP perspective to temporal logic model checking. The approach includes the notion of efficiency found in traditional model checkers, which reduced a state explosion problem through the use of efficient data structures
NASA Astrophysics Data System (ADS)
Lim, E. K.; Norizan, M. N.; Mohamad, I. S.; Yasin, M. N. M.; Murad, S. A. Z.; Baharum, N. A.; Jamalullail, N.
2017-09-01
This paper presents the design of anti-theft/cable cut real time alert system using microcontroller and GSM technology. The detection part is using the electrical circuit wire connection in detecting the voltage drop of the cable inside the microcontroller digital input port. The GSM wireless modem is used to send the location of cable cut directly to the authority mobile phone. Microcontroller SK40C with Microchip PIC16F887 is used as a controller to control the wireless modem and also the detection device. The device is able to detect and display the location of the cable cut on the LCD display besides of and sending out the location of the cable break to the authority mobile phone wirelessly via SMS.
Albert, Benjamin; Knight, Britta; Merwin, Jason; Martin, Victoria; Ottoz, Diana; Gloor, Yvonne; Bruzzone, Maria Jessica; Rudner, Adam; Shore, David
2016-11-17
Cell growth potential is determined by the rate of ribosome biogenesis, a complex process that requires massive and coordinated transcriptional output. In the yeast Saccharomyces cerevisiae, ribosome biogenesis is highly regulated at the transcriptional level. Although evidence for a system that coordinates ribosomal RNA (rRNA) and ribosomal protein gene (RPG) transcription has been described, the molecular mechanisms remain poorly understood. Here we show that an interaction between the RPG transcriptional activator Ifh1 and the rRNA processing factor Utp22 serves to coordinate RPG transcription with that of rRNA. We demonstrate that Ifh1 is rapidly released from RPG promoters by a Utp22-independent mechanism following growth inhibition, but that its long-term dissociation requires Utp22. We present evidence that RNA polymerase I activity inhibits the ability of Utp22 to titrate Ifh1 from RPG promoters and propose that a dynamic Ifh1-Utp22 interaction fine-tunes RPG expression to coordinate RPG and rRNA transcription. Copyright © 2016 Elsevier Inc. All rights reserved.
1ST International Workshop on Managing Interactions in Smart Environments (MANSE 99)
1999-12-01
having diverse functionality. It seems likely that eventually the functionality of PDA’s and mobile phones will be integrated into similar sized devices ...The O’Reilly institute is soon to be wired with sensors and detection devices which will allow wireless communication and interaction with the...on wireless short-range communication. The prototypes are functionally self- contained mobile devices that do not rely on any further infrastructure
Performance of a scanning laser line striper in outdoor lighting
NASA Astrophysics Data System (ADS)
Mertz, Christoph
2013-05-01
For search and rescue robots and reconnaissance robots it is important to detect objects in their vicinity. We have developed a scanning laser line striper that can produce dense 3D images using active illumination. The scanner consists of a camera and a MEMS-micro mirror based projector. It can also detect the presence of optically difficult material like glass and metal. The sensor can be used for autonomous operation or it can help a human operator to better remotely control the robot. In this paper we will evaluate the performance of the scanner under outdoor illumination, i.e. from operating in the shade to operating in full sunlight. We report the range, resolution and accuracy of the sensor and its ability to reconstruct objects like grass, wooden blocks, wires, metal objects, electronic devices like cell phones, blank RPG, and other inert explosive devices. Furthermore we evaluate its ability to detect the presence of glass and polished metal objects. Lastly we report on a user study that shows a significant improvement in a grasping task. The user is tasked with grasping a wire with the remotely controlled hand of a robot. We compare the time it takes to complete the task using the 3D scanner with using a traditional video camera.
NASA Astrophysics Data System (ADS)
Wang, M. D.; Li, D. S.; Huang, Y.; Zhang, C.; Zhong, K. M.; Sun, L. N.
2013-08-01
In the notebook and clamshell mobile phone, data communication wire often requires repeated bending. Generally, communication wire with the actual application conditions, the test data cannot assess bending resistance performance of data communication wire is tested conventionally using wires with weights of 90 degree to test bending number, this test method and device is not fully reflect the fatigue performance in high frequency and light load application condition, at the same time it has a large difference between the test data of the long-term reliability of high frequency and low load conditions. In this paper, high frequency light load fatigue testing machine based on the giant magnetostrictive material and stroke multiplier is put forward, in which internal reflux stroke multiplier is driven by giant magnetostrictive material to realize the rapid movement of light load. This fatigue testing device has the following advantages: (1) When the load is far less than the friction, reducing friction is very effective to improve the device performance. Because the body is symmetrical, the friction loss of radial does not exist in theory, so the stress situation of mechanism is good with high transmission efficiency and long service life. (2) The installation position of the output hydraulic cylinder, can be arranged conveniently as ordinary cylinder. (3) Reciprocating frequency, displacement and speed of high frequency movement can be programmed easily to change with higher position precision. (4)Hydraulic oil in this device is closed to transmit, which does not produce any environment pollution. The device has no hydraulic pump and tank, and less energy conversion processes, so it is with the trend of green manufacturing.
Zulewska, J; Newbold, M; Barbano, D M
2009-04-01
Raw milk (2,710 kg) was separated at 4 degrees C, the skim milk was pasteurized (72 degrees C, 16 s), split into 3 batches, and microfiltered using pilot-scale ceramic uniform transmembrane pressure (UTP; Membralox model EP1940GL0.1microA, 0.1 microm alumina, Pall Corp., East Hills, NY), ceramic graded permeability (GP; Membralox model EP1940GL0.1microAGP1020, 0.1 microm alumina, Pall Corp.), and polymeric spiral-wound (SW; model FG7838-OS0x-S, 0.3 microm polyvinylidene fluoride, Parker-Hannifin, Process Advanced Filtration Division, Tell City, IN) membranes. There were differences in flux among ceramic UTP, ceramic GP, and polymeric SW microfiltration membranes (54.08, 71.79, and 16.21 kg/m2 per hour, respectively) when processing skim milk at 50 degrees C in a continuous bleed-and-feed 3x process. These differences in flux among the membranes would influence the amount of membrane surface area required to process a given volume of milk in a given time. Further work is needed to determine if these differences in flux are maintained over longer processing times. The true protein contents of the microfiltration permeates from UTP and GP membranes were higher than from SW membranes (0.57, 0.56, and 0.38%, respectively). Sodium-dodecyl-sulfate-PAGE gels for permeates revealed a higher casein proportion in GP and SW permeate than in UTP permeate, with the highest passage of casein through the GP membrane under the operational conditions used in this study. The slight cloudiness of the permeates produced using the GP and SW systems may have been due to the presence of a small amount of casein, which may present an obstacle in their use in applications when clarity is an important functional characteristic. More beta-lactoglobulin passed through the ceramic membranes than through the polymeric membrane. The efficiency of removal of serum proteins in a continuous bleed-and-feed 3x process at 50 degrees C was 64.40% for UTP, 61.04% for GP, and 38.62% for SW microfiltration membranes. The SW polymeric membranes had a much higher rejection of serum proteins than did the ceramic membranes, consistent with the sodium-dodecyl-sulfate PAGE data. Multiple stages and diafiltration would be required to produce a 60 to 65% serum protein reduced micellar casein concentrate with SW membranes, whereas only one stage would be needed for the ceramic membranes used in this study.
Effects of pyrimidines on the guinea-pig coronary vasculature.
Vials, A. J.; Burnstock, G.
1993-01-01
1. The effects of the pyrimidines, uridine 5'-triphosphate (UTP), thymidine 5'-triphosphate (TTP) and cytidine 5'-triphosphate (CTP), were examined in the guinea-pig coronary bed, by use of a Langendorff technique. Comparisons were made with the actions of the purines adenosine 5'-triphosphate (ATP), inosine 5'-triphosphate (ITP) and guanosine 5'-triphosphate (GTP). The effect of, the nitric oxide synthase inhibitor, L-NG-nitroarginine methyl ester (L-NAME) and, the prostaglandin synthesis inhibitor, indomethacin on the vasodilator response to these purines and pyrimidines was examined. The effects of these inhibitors were assessed on their ability to inhibit both the amplitude and the area of the vasodilator response. 2. The relative order of potency of the purines and pyrimidines studied was ATP > UTP > ITP >> GTP, TTP, CTP. 3. The maximum amplitude and area of the vasodilator response to the pyrimidines, UTP (5 x 10(-10)-5 x 10(-7) mol), TTP (5 x 10(-8)-5 x 10(-7) mol) and CTP (5 x 10(-7) mol), and purines, ITP (5 x 10(-9)-5 x 10(-7) mol) and GTP (5 x 10(-8)-5 x 10(-7) mol), were significantly reduced by L-NAME (3 x 10(-5) and 10(-4) M).(ABSTRACT TRUNCATED AT 250 WORDS) PMID:8298797
A Comprehensive Ubiquitous Healthcare Solution on an Android™ Mobile Device
Hii, Pei-Cheng; Chung, Wan-Young
2011-01-01
Provision of ubiquitous healthcare solutions which provide healthcare services at anytime anywhere has become more favorable nowadays due to the emphasis on healthcare awareness and also the growth of mobile wireless technologies. Following this approach, an Android™ smart phone device is proposed as a mobile monitoring terminal to observe and analyze ECG (electrocardiography) waveforms from wearable ECG devices in real time under the coverage of a wireless sensor network (WSN). The exploitation of WSN in healthcare is able to substitute the complicated wired technology, moving healthcare away from a fixed location setting. As an extension to the monitoring scheme, medicine care is taken into consideration by utilizing the mobile phone as a barcode decoder, to verify and assist out-patients in the medication administration process, providing a better and more comprehensive healthcare service. PMID:22163986
Fluorescent labeling of NASBA amplified tmRNA molecules for microarray applications
Scheler, Ott; Glynn, Barry; Parkel, Sven; Palta, Priit; Toome, Kadri; Kaplinski, Lauris; Remm, Maido; Maher, Majella; Kurg, Ants
2009-01-01
Background Here we present a novel promising microbial diagnostic method that combines the sensitivity of Nucleic Acid Sequence Based Amplification (NASBA) with the high information content of microarray technology for the detection of bacterial tmRNA molecules. The NASBA protocol was modified to include aminoallyl-UTP (aaUTP) molecules that were incorporated into nascent RNA during the NASBA reaction. Post-amplification labeling with fluorescent dye was carried out subsequently and tmRNA hybridization signal intensities were measured using microarray technology. Significant optimization of the labeled NASBA protocol was required to maintain the required sensitivity of the reactions. Results Two different aaUTP salts were evaluated and optimum final concentrations were identified for both. The final 2 mM concentration of aaUTP Li-salt in NASBA reaction resulted in highest microarray signals overall, being twice as high as the strongest signals with 1 mM aaUTP Na-salt. Conclusion We have successfully demonstrated efficient combination of NASBA amplification technology with microarray based hybridization detection. The method is applicative for many different areas of microbial diagnostics including environmental monitoring, bio threat detection, industrial process monitoring and clinical microbiology. PMID:19445684
Taylor, Scott D; Mirzaei, Farzad; Sharifi, Ali; Bearne, Stephen L
2006-12-08
Cytidine triphosphate synthetase (CTPS) catalyzes the formation of cytidine triphosphate from glutamine, uridine-5'-triphosphate (UTP), and adenosine-5'-triphosphate. Inhibitors of CTPS are of interest because of their potential as therapeutic agents. One approach to potent enzyme inhibitors is to use analogues of high energy intermediates formed during the reaction. The CTPS reaction proceeds via the high energy intermediate UTP-4-phosphate (UTP-4-P). Four novel analogues of uridine-4-phosphate (U-4-P) and 3-deazauridine-4-phosphate (3-deazaU-4-P) were synthesized in which the labile phosphate ester oxygen was replaced with a methylene and difluoromethylene group. The methylene analogue of U-4-P, compound 1, was prepared by a reaction of the sodium salt of tert-butyl diethylphosphonoacetate with protected, 4-O-activated uridine followed by acetate deprotection and decarboxylation. It was found that this compound undergoes relatively facile dephosphonylation presumably via a metaphosphate intermediate. The difluoromethylene derivative, compound 2, was prepared by electrophilic fluorination of protected 1. This compound was stable and did not undergo dephosphonylation. Synthesis of the methylene analogue of 3-deazaU-4-P, compound 3, was achieved by ribosylation of protected 4-(phosphonomethyl)-2-hydroxypyridine. Electrophilic fluorination was also employed in the preparation of protected 4-(phosphonodifluoromethyl)-2-hydroxypyridine which was used as the key building block in the synthesis of difluoro derivative 4. These compounds represent the first examples of a nucleoside in which the base has been chemically modified with a methylene or difluormethylenephosphonate group.
Evidence that ATP acts at two sites to evoke contraction in the rat isolated tail artery.
McLaren, G J; Burke, K S; Buchanan, K J; Sneddon, P; Kennedy, C
1998-05-01
1. The site(s) at which P2-receptor agonists act to evoke contractions of the rat isolated tail artery was studied by use of P2-receptor antagonists and the extracellular ATPase inhibitor 6-N,N-diethyl-D-beta,gamma-dibromomethyleneATP (ARL 67156). 2. Suramin (1 microM(-1) mM) and pyridoxalphosphate-6-azophenyl-2',4'-disulphonic acid (PPADS) (0.3-300 microM) inhibited contractions evoked by equi-effective concentrations of alpha,beta-methyleneATP (alpha,beta-meATP) (5 microM), 2-methylthioATP (2-meSATP) (100 microM) and adenosine 5'-triphosphate (ATP) (1 mM) in a concentration-dependent manner. Responses to alpha,beta-meATP and 2-meSATP were abolished, but approximately one third of the peak response to ATP was resistant to suramin and PPADS. 3. Contractions evoked by uridine 5'-triphosphate (UTP) (1 mM) were slightly inhibited by suramin (100 and 300 microM) and potentiated by PPADS (300 microM). 4. Desensitization of the P2X1-receptor by alpha,beta-meATP abolished contractions evoked by 2-meSATP (100 microM) and reduced those to ATP (1 mM) and UTP (1 mM) to 15+/-3% and 68+/-4% of control. 5. Responses to alpha,beta-meATP (5 microM) and 2-meSATP (100 microM) were abolished when tissues were bathed in nominally calcium-free solution, while the peak contractions to ATP (1 mM) and UTP (1 mM) were reduced to 24+/-6% and 61+/-13%, respectively, of their control response. 6. ARL 67156 (3-100 microM) potentiated contractions elicited by UTP (1 mM), but inhibited responses to alpha,beta-meATP (5 microM), 2-meSATP (100 microM) and ATP (1 mM) in a concentration-dependent manner. 7. These results suggest that two populations of P2-receptors are present in the rat tail artery; ligand-gated P2X1-receptors and G-protein-coupled P2Y-receptors.
Multiple P2Y receptor subtypes in the apical membranes of polarized epithelial cells
McAlroy, H L; Ahmed, S; Day, S M; Baines, D L; Wong, H Y; Yip, C Y; Ko, W H; Wilson, S M; Collett, A
2000-01-01
Apical ATP, ATP, UTP and UDP evoked transient increases in short circuit current (ISC, a direct measure of transepithelial ion transport) in confluent Caco-2 cells grown on permeable supports. These responses were mediated by a population of at least three pharmacologically distinct receptors. Experiments using cells grown on glass coverslips showed that ATP and UTP consistently increased intracellular free calcium ([Ca2+]i) whilst sensitivity to UDP was variable. Cross desensitization experiments suggested that the responses to UTP and ATP were mediated by a common receptor population. Messenger RNA transcripts corresponding to the P2Y2, P2Y4 and P2Y6 receptors genes were detected in cells grown on Transwell membranes by the reverse transcriptase–polymerase chain reaction. Identical results were obtained for cells grown on glass. Experiments in which ISC and [Ca2+]i were monitored simultaneously in cells on Transwell membranes, confirmed that apical ATP and UTP increased both parameters and showed that the UDP-evoked increase in ISC was accompanied by a [Ca2+]i-signal. Ionomycin consistently increased [Ca2+]i in such polarized cells but caused no discernible change in ISC. However, subsequent application of apical ATP or UTP evoked a small rise in ISC but no rise in [Ca2+]i. UDP evoked no such response. As well as evoking increases in [Ca2+]i, the ATP/UTP-sensitive receptors present in Caco-2 cells thus allow direct control over ion channels in the apical membrane. The UDP-sensitive receptors, however, appear to simply evoke a rise in [Ca2+]i. PMID:11139443
Investigations of metal leaching from mobile phone parts using TCLP and WET methods.
Yadav, Satyamanyu; Yadav, Sudesh
2014-11-01
Metal leaching from landfills containing end-of-life or otherwise discarded mobile phones poses a threat to the environment as well as public health. In the present study, the metal toxicity of printed wire boards (PWBs), plastics, liquid crystal displays (LCDs) and batteries of mobile phones was assessed using the Toxicity Characteristics Leaching Procedures (TCLP) and the Waste Extraction Test (WET). The PWBs failed TCLP for Pb and Se, and WET for Pb and Zn. In WET, the two PWB samples for Pb and Zn and the battery samples for Co and Cu failed the test. Furthermore, the PWBS for Ni and the battery samples for Ni and Co failed the WET in their TCLP leachates. Both, Ni and Co are the regulatory metals in only WET and not covered under TCLP. These observations indicate that the TCLP seems to be a more aggressive test than the WET for the metal leaching from the mobile phone parts. The compositional variations, nature of leaching solution (acetate in TCLP and citrate in WET) and the redox conditions in the leaching solution of the PWBs resulted in different order of metals with respect to their amounts of leaching from PWBs in TCLP (Fe > Pb > Zn > Ni > Co > Cu) and WET (Zn > Fe > Ni > Pb > Cu). The metal leaching also varied with the make, manufacturing year and part of the mobile phone tested. PWBs, plastics and batteries should be treated as hazardous waste. Metal leaching, particularly of Se and Pb, from mobile phones can be harmful to the environment and human health. Therefore, a scientifically sound and environmentally safe handling and disposal management system needs to be evolved for the mobile phone disposal. Copyright © 2014 Elsevier Ltd. All rights reserved.
Functional effects of uridine triphosphate on human skinned skeletal muscle fibers.
Vianna-Jorge, R; Oliveira, C F; Mounier, Y; Suarez-Kurtz, G
1998-02-01
Chemically skinned human skeletal muscle fibers were used to study the effects of uridine triphosphate (UTP) on the tension-pCa relationship and on Ca2+ uptake and release by the sarcoplasmic reticulum (SR). Total replacement (2.5 mM) of adenosine triphosphate (ATP) with UTP (i) displaced the tension-pCa relationship to the left along the abcissae and increased maximum Ca(2+)-activated tension, both effects being larger in slow- than in fast-type fibers; (ii) markedly reduced Ca2+ uptake by the SR (evaluated by the caffeine-evoked tension) in both fiber types; (iii) had no effect on the rate of depletion of caffeine-sensitive Ca2+ stores during soaking in relaxing solutions; (iv) induced tension in slow- but not in fast-type fibers. The effects on the SR functional properties are consistent with the notion that UTP is a poor substitute for ATP as a substrate for the Ca ATPase pump and as an agonist of the ryanodine-sensitive Ca(2+)-release channel. The UTP-induced tension in human slow-type fibers is attributed to effect(s) of the nucleotide on the tension-pCa relationship of the contractile machinery. The present data reveal important differences between the effects of UTP on human versus rat muscle fibers.
Technical note: real-time web-based wireless visual guidance system for radiotherapy.
Lee, Danny; Kim, Siyong; Palta, Jatinder R; Kim, Taeho
2017-06-01
Describe a Web-based wireless visual guidance system that mitigates issues associated with hard-wired audio-visual aided patient interactive motion management systems that are cumbersome to use in routine clinical practice. Web-based wireless visual display duplicates an existing visual display of a respiratory-motion management system for visual guidance. The visual display of the existing system is sent to legacy Web clients over a private wireless network, thereby allowing a wireless setting for real-time visual guidance. In this study, active breathing coordinator (ABC) trace was used as an input for visual display, which captured and transmitted to Web clients. Virtual reality goggles require two (left and right eye view) images for visual display. We investigated the performance of Web-based wireless visual guidance by quantifying (1) the network latency of visual displays between an ABC computer display and Web clients of a laptop, an iPad mini 2 and an iPhone 6, and (2) the frame rate of visual display on the Web clients in frames per second (fps). The network latency of visual display between the ABC computer and Web clients was about 100 ms and the frame rate was 14.0 fps (laptop), 9.2 fps (iPad mini 2) and 11.2 fps (iPhone 6). In addition, visual display for virtual reality goggles was successfully shown on the iPhone 6 with 100 ms and 11.2 fps. A high network security was maintained by utilizing the private network configuration. This study demonstrated that a Web-based wireless visual guidance can be a promising technique for clinical motion management systems, which require real-time visual display of their outputs. Based on the results of this study, our approach has the potential to reduce clutter associated with wired-systems, reduce space requirements, and extend the use of medical devices from static usage to interactive and dynamic usage in a radiotherapy treatment vault.
Mobile phones improve antenatal care attendance in Zanzibar: a cluster randomized controlled trial
2014-01-01
Background Applying mobile phones in healthcare is increasingly prioritized to strengthen healthcare systems. Antenatal care has the potential to reduce maternal morbidity and improve newborns’ survival but this benefit may not be realized in sub-Saharan Africa where the attendance and quality of care is declining. We evaluated the association between a mobile phone intervention and antenatal care in a resource-limited setting. We aimed to assess antenatal care in a comprehensive way taking into consideration utilisation of antenatal care as well as content and timing of interventions during pregnancy. Methods This study was an open label pragmatic cluster-randomised controlled trial with primary healthcare facilities in Zanzibar as the unit of randomisation. 2550 pregnant women (1311 interventions and 1239 controls) who attended antenatal care at selected primary healthcare facilities were included at their first antenatal care visit and followed until 42 days after delivery. 24 primary health care facilities in six districts were randomized to either mobile phone intervention or standard care. The intervention consisted of a mobile phone text-message and voucher component. Primary outcome measure was four or more antenatal care visits during pregnancy. Secondary outcome measures were tetanus vaccination, preventive treatment for malaria, gestational age at last antenatal care visit, and antepartum referral. Results The mobile phone intervention was associated with an increase in antenatal care attendance. In the intervention group 44% of the women received four or more antenatal care visits versus 31% in the control group (OR, 2.39; 95% CI, 1.03-5.55). There was a trend towards improved timing and quality of antenatal care services across all secondary outcome measures although not statistically significant. Conclusions The wired mothers’ mobile phone intervention significantly increased the proportion of women receiving the recommended four antenatal care visits during pregnancy and there was a trend towards improved quality of care with more women receiving preventive health services, more women attending antenatal care late in pregnancy and more women with antepartum complications identified and referred. Mobile phone applications may contribute towards improved maternal and newborn health and should be considered by policy makers in resource-limited settings. Trial registration ClinicalTrials.gov, NCT01821222. PMID:24438517
Adams, Michael C; Hurt, Emily E; Barbano, David M
2015-11-01
Our objectives were to determine the effects of a ceramic microfiltration (MF) membrane's retentate flow channel geometry (round or diamond-shaped) and uniform transmembrane pressure (UTP) on limiting flux (LF) and serum protein (SP) removal during skim milk MF at a temperature of 50°C, a retentate protein concentration of 8.5%, and an average cross-flow velocity of 7 m·s(-1). Performance of membranes with round and diamond flow channels was compared in UTP mode. Performance of the membrane with round flow channels was compared with and without UTP. Using UTP with round flow channel MF membranes increased the LF by 5% when compared with not using UTP, but SP removal was not affected by the use of UTP. Using membranes with round channels instead of diamond-shaped channels in UTP mode increased the LF by 24%. This increase was associated with a 25% increase in Reynolds number and can be explained by lower shear at the vertices of the diamond-shaped channel's surface. The SP removal factor of the diamond channel system was higher than the SP removal factor of the round channel system below the LF. However, the diamond channel system passed more casein into the MF permeate than the round channel system. Because only one batch of each membrane was tested in our study, it was not possible to determine if the differences in protein rejection between channel geometries were due to the membrane design or random manufacturing variation. Despite the lower LF of the diamond channel system, the 47% increase in membrane module surface area of the diamond channel system produced a modular permeate removal rate that was at least 19% higher than the round channel system. Consequently, using diamond channel membranes instead of round channel membranes could reduce some of the costs associated with ceramic MF of skim milk if fewer membrane modules could be used to attain the required membrane area. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Sloan, Katherine E.; Bohnsack, Markus T.; Schneider, Claudia; Watkins, Nicholas J.
2014-01-01
During eukaryotic ribosome biogenesis, three of the mature ribosomal (r)RNAs are released from a single precursor transcript (pre-rRNA) by an ordered series of endonucleolytic cleavages and exonucleolytic processing steps. Production of the 18S rRNA requires the removal of the 5′ external transcribed spacer (5′ETS) by endonucleolytic cleavages at sites A0 and A1/site 1. In metazoans, an additional cleavage in the 5′ETS, at site A′, upstream of A0, has also been reported. Here, we have investigated how A′ processing is coordinated with assembly of the early preribosomal complex. We find that only the tUTP (UTP-A) complex is critical for A′ cleavage, while components of the bUTP (UTP-B) and U3 snoRNP are important, but not essential, for efficient processing at this site. All other factors involved in the early stages of 18S rRNA processing that were tested here function downstream from this processing step. Interestingly, we show that the RNA surveillance factors XRN2 and MTR4 are also involved in A′ cleavage in humans. A′ cleavage is largely bypassed when XRN2 is depleted, and we also discover that A′ cleavage is not always the initial processing event in all cell types. Together, our data suggest that A′ cleavage is not a prerequisite for downstream pre-rRNA processing steps and may, in fact, represent a quality control step for initial pre-rRNA transcripts. Furthermore, we show that components of the RNA surveillance machinery, including the exosome and TRAMP complexes, also play key roles in the recycling of excised spacer fragments and degradation of aberrant pre-rRNAs in human cells. PMID:24550520
Pharmacological and biochemical analysis of FPL 67156, a novel, selective inhibitor of ecto-ATPase.
Crack, B E; Pollard, C E; Beukers, M W; Roberts, S M; Hunt, S F; Ingall, A H; McKechnie, K C; IJzerman, A P; Leff, P
1995-01-01
1. FPL 67156 (6-N,N-diethyl-beta, gamma-dibromomethylene-D-ATP), is a newly synthesized analogue of ATP. 2. In a rabbit isolated tracheal epithelium preparation, measuring P2U-purinoceptor-dependent chloride secretion, FPL 67156 was discovered to potentiate the responses to UTP but not those to ATP-gamma-S. UTP agonist-concentration effect (E/[A]) curves were shifted to the left by 5-fold in the presence of 100 microM FPL 67156. The differential effect of FPL 67156 on UTP and ATP-gamma-S was hypothesized to be due to the greater susceptibility of UTP to enzymatic dephosphorylation and the ability of FPL 67156 to inhibit this process. 3. FPL 67156 was tested as an ecto-ATPase inhibitor in a human blood cell assay, measuring [gamma 32P]-ATP dephosphorylation. The compound inhibited [gamma 32P]-ATP degradation with a pIC50 of 4.6. 4. FPL 67156 was then tested for its effects on ATP and alpha, beta-methylene-ATP responses at P2X-purinoceptors in the rabbit isolated ear artery. In the concentration range 30 microM-1 mM, the compound potentiated the contractile effects of ATP but not those of alpha, beta-methylene-ATP. At 1 mM, FPL 67156 produced a 34-fold leftward shift of ATP E/[A] curves. 5. The effects of FPL 67156 on ATP E/[A] curves in the rabbit ear artery were analyzed using a theoretical model (Furchgott, 1972) describing the action of an enzyme inhibitor on the effects of a metabolically unstable agonist. This analysis provided an estimate of the pKi for FPL 67156 as an ecto-ATPase inhibitor of 5.2.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:7533620
Gailly, P; Szutkowska, M; Olinger, E; Debaix, H; Seghers, F; Janas, S; Vallon, V; Devuyst, O
2014-11-01
Luminal nucleotide stimulation is known to reduce Na(+) transport in the distal nephron. Previous studies suggest that this mechanism may involve the thiazide-sensitive Na(+)-Cl(-) cotransporter (NCC), which plays an essential role in NaCl reabsorption in the cells lining the distal convoluted tubule (DCT). Here we show that stimulation of mouse DCT (mDCT) cells with ATP or UTP promoted Ca(2+) transients and decreased the expression of NCC at both mRNA and protein levels. Specific siRNA-mediated silencing of P2Y2 receptors almost completely abolished ATP/UTP-induced Ca(2+) transients and significantly reduced ATP/UTP-induced decrease of NCC expression. To test whether local variations in the intracellular Ca(2+) concentration ([Ca(2+)]i) may control NCC transcription, we overexpressed the Ca(2+)-binding protein parvalbumin selectively in the cytosol or in the nucleus of mDCT cells. The decrease in NCC mRNA upon nucleotide stimulation was abolished in cells overexpressing cytosolic PV but not in cells overexpressing either a nuclear-targeted PV or a mutated PV unable to bind Ca(2+). Using a firefly luciferase reporter gene strategy, we observed that the activity of NCC promoter region from -1 to -2,200 bp was not regulated by changes in [Ca(2+)]i. In contrast, high cytosolic calcium level induced instability of NCC mRNA. We conclude that in mDCT cells: (1) P2Y2 receptor is essential for the intracellular Ca(2+) signaling induced by ATP/UTP stimulation; (2) P2Y2-mediated increase of cytoplasmic Ca(2+) concentration down-regulates the expression of NCC; (3) the decrease of NCC expression occurs, at least in part, via destabilization of its mRNA.
NASA Astrophysics Data System (ADS)
Clarke, K. C.
2009-12-01
There are growing concerns among leading national and local organizations about American scientific literacy, fundamental understanding of science, and the value of scientific research. These organizations, including the University Corporation for Atmospheric Research, have been at the forefront in addressing these concerns. In an effort to improve scientific literacy, research conducted by Sam Droege, among others, suggested using citizen science and public participation as instrumental methods to engage the public. Urban Tree Phenology (UTP), a project of Project BudBurst and the USDA Forest Service, is one such citizen science program that sought to engage the public, including the professionals and amateurs among them, in collecting urban tree phenophase data. UTP participants monitored and reported the stages of phenological events, such as First Leaf and Leaf Fall, of 24 native and cultivated urban tree species, using the steps shown in Figure 1. Data collected will support the long-term research of plant ecology, climate change, public health, urban heat islands on tree physiology, and urban tree management. UTP, using the architectures of online learning, has developed two instructional tutorials to assist data collection (Phase 1). The instructional tutorials were published online, in print and PowerPoint formats, at www.UrbanTreePhenology.com. By completing these tutorials, participants will gain the skills necessary to provide urban tree phenological data to national research databases via the Internet. Phase 2 will test and review the instructional materials developed, and in Phase 3, the administrators of UTP will distribute promotional materials to national research organizations and to participants of the Project BudBurst national citizen science campaign.
26 CFR 1.465-27 - Qualified nonrecourse financing.
Code of Federal Regulations, 2010 CFR
2010-04-01
... partnership; incidental property. (i) X is a limited liability company that is classified as a partnership for.... (i) UTP1 and UTP2, both limited liability companies classified as partnerships, are the only general... as qualified nonrecourse financing. (4) Partnership liability. For purposes of section 465(b)(6) and...
2010-11-01
protection and to isolate threats in order to survive and develop. The cell model implies osmosis , allowing flows to take place across the borders and the...relationships to new levels, much as cell phone technology replaces the laying of copper wire for traditional telephone service. Whole-of-Government/Whole...in urban, rural, and remote environments. This practical experience with the men and women of the U.S. Border Patrol animated many of the concepts
ERIC Educational Resources Information Center
Lee, Wynetta Y.
This study examined the role of the North Carolina State University Transition Program (UTP) in enhancing transition of disadvantaged students from high school and increasing their persistence to degree. The UTP, which targets academically underprepared African American and Native American students, provides special courses and counseling…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-22
...) (Preliminary Determination). On June 12, 2012, respondent Universal Tube and Plastic Industries, Ltd. (UTP-JA... Universal Tube and Plastic Industries, Ltd. in the Antidumping Duty Investigation of Circular Welded Carbon... Verification of Universal Tube and Plastic Industries, Ltd. (UTP-JA) and Its Home Market Affiliates...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-22
... ``devices'' and/or ``UserIDs.'' \\4\\ OPRA defines a ``Subscriber,'' in general, as an entity or person that... Exchanges on an Unlisted Trading Privilege Basis'' (``Nasdaq/UTP Plan''). CTA and the Nasdaq/UTP Plan define... capacity.\\9\\ Second, because the definition of the term ``associated person'' is defined differently in the...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-21
... Market Maker'') in a derivative securities product (``UTP Derivative Security'') that derives its value... Derivative Security on the Exchange(s) from acting or registering as a market maker on any other exchange in any Reference Asset of that UTP Derivative Security, or any derivative instrument based on a Reference...
What is harmful for male fertility: cell phone or the wireless Internet?
Yildirim, Mehmet Erol; Kaynar, Mehmet; Badem, Huseyin; Cavis, Mucahıt; Karatas, Omer Faruk; Cimentepe, Ersın
2015-09-01
In this study, we aimed to assess the potential harmful effects of radiofrequency-electromagnetic radiation on sperm parameters. We requested semen for analyses from the male patients coming to our infertility division and also asked them to fill out an anonymous questionnaire. We queried their mobile phone and wireless Internet usage frequencies in order to determine their radiofrequency-electromagnetic radiation exposure. A total of 1082 patients filled the questionnaire but 51 of them were excluded from the study because of azoospermia. There was no significant difference between sperm counts and sperm morphology excluding sperm motility, due to mobile phone usage period, (p = 0.074, p = 0.909, and p = 0.05, respectively). The total motile sperm count and the progressive motile sperm count decreased due to the increase of internet usage (p = 0.032 and p = 0.033, respectively). In line with the total motile sperm count, progressive motile sperm count also decreased with wireless Internet usage compared with the wired Internet connection usage (p = 0.009 and p = 0.018, respectively). There was a negative correlation between wireless Internet usage duration and the total sperm count (r = -0.089, p = 0.039). We have also explored the negative effect of wireless Internet use on sperm motility according to our preliminary results. Copyright © 2015. Published by Elsevier Taiwan.
Andó, RD; Méhész, B; Gyires, K; Illes, P; Sperlágh, B
2010-01-01
Background and purpose: This study was undertaken to compare the analgesic activity of antagonists acting at P2X1, P2X7, and P2Y12 receptors and agonists acting at P2Y1, P2Y2, P2Y4, and P2Y6 receptors in neuropathic, acute, and inflammatory pain. Experimental approach: The effect of the wide spectrum P2 receptor antagonist PPADS, the selective P2X7 receptor antagonist Brilliant Blue G (BBG), the P2X1 receptor antagonist (4,4′,4″,4-[carbonylbis(imino-5,1,3-benzenetriyl-bis(carbonylimino))]tetrakis-1,3-benzenedisulfonic acid, octasodium salt (NF449) and (8,8′-[carbonylbis(imino-3,1-phenylenecarbonylimino)]bis-1,3,5-naphthalene-trisulphonic acid, hexasodium salt (NF023), the P2Y12 receptor antagonist (2,2-dimethyl-propionic acid 3-(2-chloro-6-methylaminopurin-9-yl)-2-(2,2-dimethyl-propionyloxymethyl)-propylester (MRS2395), the selective P2Y1 receptor agonist ([[(1R,2R,3S,4R,5S)-4-[6-amino-2-(methylthio)-9H-purin-9-yl]-2,3-dihydroxybicyclo[3.1.0]hex-1-yl]methyl] diphosphoric acid mono ester trisodium salt (MRS2365), the P2Y2/P2Y4 agonist uridine-5′-triphosphate (UTP), and the P2Y4/P2Y6 agonist uridine-5′-diphosphate (UDP) were examined on mechanical allodynia in the Seltzer model of neuropathic pain, on acute thermal nociception, and on the inflammatory pain and oedema induced by complete Freund's adjuvant (CFA). Key results: MRS2365, MRS2395 and UTP, but not the other compounds, significantly alleviated mechanical allodynia in the neuropathic pain model, with the following rank order of minimal effective dose (mED) values: MRS2365 > MRS2395 > UTP. All compounds had a dose-dependent analgesic action in acute pain except BBG, which elicited hyperalgesia at a single dose. The rank order of mED values in acute pain was the following: MRS2365 > MRS2395 > NF449 > NF023 > UDP = UTP > PPADS. MRS2365 and MRS2395 had a profound, while BBG had a mild effect on inflammatory pain, with a following rank order of mED values: MRS2395 > MRS2365 > BBG. None of the tested compounds had significant action on oedema evoked by intraplantar injection of CFA. Conclusions and implications: Our results show that antagonism at P2X1, P2Y12, and P2X7 receptors and agonism at P2Y1 receptors define promising therapeutic strategies in acute, neuropathic, and inflammatory pain respectively. PMID:20136836
Andó, R D; Méhész, B; Gyires, K; Illes, P; Sperlágh, B
2010-03-01
This study was undertaken to compare the analgesic activity of antagonists acting at P2X1, P2X7, and P2Y12 receptors and agonists acting at P2Y1, P2Y2, P2Y4, and P2Y6 receptors in neuropathic, acute, and inflammatory pain. The effect of the wide spectrum P2 receptor antagonist PPADS, the selective P2X7 receptor antagonist Brilliant Blue G (BBG), the P2X1 receptor antagonist (4,4',4'',4-[carbonylbis(imino-5,1,3-benzenetriyl-bis(carbonylimino))]tetrakis-1,3-benzenedisulfonic acid, octasodium salt (NF449) and (8,8'-[carbonylbis(imino-3,1-phenylenecarbonylimino)]bis-1,3,5-naphthalene-trisulphonic acid, hexasodium salt (NF023), the P2Y12 receptor antagonist (2,2-dimethyl-propionic acid 3-(2-chloro-6-methylaminopurin-9-yl)-2-(2,2-dimethyl-propionyloxymethyl)-propylester (MRS2395), the selective P2Y1 receptor agonist ([[(1R,2R,3S,4R,5S)-4-[6-amino-2-(methylthio)-9H-purin-9-yl]-2,3-dihydroxybicyclo[3.1.0]hex-1-yl]methyl] diphosphoric acid mono ester trisodium salt (MRS2365), the P2Y2/P2Y4 agonist uridine-5'-triphosphate (UTP), and the P2Y4/P2Y6 agonist uridine-5'-diphosphate (UDP) were examined on mechanical allodynia in the Seltzer model of neuropathic pain, on acute thermal nociception, and on the inflammatory pain and oedema induced by complete Freund's adjuvant (CFA). MRS2365, MRS2395 and UTP, but not the other compounds, significantly alleviated mechanical allodynia in the neuropathic pain model, with the following rank order of minimal effective dose (mED) values: MRS2365 > MRS2395 > UTP. All compounds had a dose-dependent analgesic action in acute pain except BBG, which elicited hyperalgesia at a single dose. The rank order of mED values in acute pain was the following: MRS2365 > MRS2395 > NF449 > NF023 > UDP = UTP > PPADS. MRS2365 and MRS2395 had a profound, while BBG had a mild effect on inflammatory pain, with a following rank order of mED values: MRS2395 > MRS2365 > BBG. None of the tested compounds had significant action on oedema evoked by intraplantar injection of CFA. Our results show that antagonism at P2X1, P2Y12, and P2X7 receptors and agonism at P2Y1 receptors define promising therapeutic strategies in acute, neuropathic, and inflammatory pain respectively.
Construction of an automated fiber pigtailing machine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Strand, O.T.
1996-01-01
At present, the high cost of optoelectronic (OE) devices is caused in part by the labor-intensive processes involved with packaging. Automating the packaging processes should result in a significant cost reduction. One of the most labor-intensive steps is aligning and attaching the fiber to the OE device, the so-called pigtailing process. Therefore, the goal of this 2-year ARPA-funded project is to design and build 3 low-cost machines to perform sub-micron alignments and attachments of single-mode fibers to different OE devices. These Automated Fiber Pigtailing Machines (AFPMS) are intended to be compatible with a manufacturing environment and have a modular designmore » for standardization of parts and machine vision for maximum flexibility. This work is a collaboration among Uniphase Telecommunications Products (formerly United Technologies Photonics, UTP), Ortel, Newport/Klinger, the Massachusetts Institute of Technology Manufacturing Institute (MIT), and Lawrence Livermore National Laboratory (LLNL). UTP and Ortel are the industrial partners for whom two of the AFPMs are being built. MIT and LLNL make up the design and assembly team of the project, while Newport/Klinger is a potential manufacturer of the AFPM and provides guidance to ensure that the design of the AFPM is marketable and compatible with a manufacturing environment. The AFPM for UTP will pigtail LiNbO{sub 3} waveguide devices and the AFPM for Ortel will pigtail photodiodes. Both of these machines will contain proprietary information, so the third AFPM, to reside at LLNL, will pigtail a non-proprietary waveguide device for demonstrations to US industry.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Osibanjo, Oladele; Nnorom, Innocent Chidi
Presently, Nigeria is one of the fastest growing Telecom markets in the world. The country's teledensity increased from a mere 0.4 in 1999 to 10 in 2005 following the liberalization of the Telecom sector in 2001. More than 25 million new digital mobile lines have been connected by June 2006. Large quantities of mobile phones and accessories including secondhand and remanufactured products are being imported to meet the pent-up demand. This improvement in mobile telecom services resulted in the preference of mobile telecom services to fixed lines. Consequently, the contribution of fixed lines decreased from about 95% in year 2000more » to less than 10% in March 2005. This phenomenal progress in information technology has resulted in the generation of large quantities of electronic waste (e-waste) in the country. Abandoned fixed line telephone sets estimated at 120,000 units are either disposed or stockpiled. Increasing quantities of waste mobile phones estimated at 8 million units by 2007, and accessories will be generated. With no material recovery facility for e-waste and/or appropriate solid waste management infrastructure in place, these waste materials end up in open dumps and unlined landfills. These practices create the potential for the release of toxic metals and halocarbons from batteries, printed wiring boards, liquid crystal display and plastic housing units. This paper presents an overview of the developments in the Nigerian Telecom sector, the material in-flow of mobile phones, and the implications of the management practices for wastes from the Telecom sector in the country.« less
Jacobsen, Wade C; Forste, Renata
2011-05-01
Little is known about the influence of electronic media use on the academic and social lives of university students. Using time-diary and survey data, we explore the use of various types of electronic media among first-year students. Time-diary results suggest that the majority of students use electronic media to multitask. Robust regression results indicate a negative relationship between the use of various types of electronic media and first-semester grades. In addition, we find a positive association between social-networking-site use, cellular-phone communication, and face-to-face social interaction.
Nucleotide-mediated relaxation in guinea-pig aorta: selective inhibition by MRS2179
Kaiser, Robert A; Buxton, Iain L O
2002-01-01
The vasodilatory effects of nucleotides in the guinea-pig thoracic aorta were examined to determine the relationship between molecular expression and function of P2Y receptors. In aortic rings precontracted with norepinephrine, vasodilatory responses to purine nucleotides exhibited a rank-order of potency of 2-methylthio-ATP>ADP>ATP. Responses to UTP, but not UDP suggested a functional role for P2Y4 but not P2Y6 receptors. Aortic endothelial cells express at least four P2Y receptors; P2Y1, P2Y2, P2Y4 and P2Y6. In primary culture, these cells exhibit desensitizing transient calcium responses characteristic of P2Y1, P2Y2 and P2Y4, but not P2Y6 receptors. UDP had no effect on endothelial cell calcium. The pyrimidinergic receptor agonist UTP is capable of eliciting robust vasodilation in aortic rings and causing calcium responses in cultured guineapig aortic endothelial cells. These responses are equivalent to the maximum responses observed to ATP and ADP. Measurement of intracellular calcium release in response to ATP and 2-methylthio-ATP were similar, however only the 2-methylthio-ATP response was sensitive to the P2Y1 antagonist N6-methyl-2′-deoxyadenosine-3′,5′-bisphosphate (MRS2179). In aortic rings, vasodilatory responses to 2-methylthio-ATP, ATP and ADP were all blocked by pre-incubation of tissues with MRS2179. MRS2179 pretreatment had no effect of the ability of UTP to cause relaxation of norepinephrine responses in aortic rings or the ability of UTP to cause calcium release in aortic endothelial cells. We demonstrate robust effects of purine and pyrimidine nucleotides in guineapig aorta and provide functional and biochemical evidence that MRS2179 is a selective P2Y1 antagonist. PMID:11815389
2016-06-28
Sea, the results of which will support all of the objectives listed above. APPROACH APL-UW employed a combination of experimental measurements, data...APPROACH APL-UW employs a combination of experimental measurements, data analysis, simulations, and theoretical development to address the objectives...RD cases, respectively). In the RI case, the UTP moves back and forth along a curve. In the RD case, the UTP traces out an ellipse. The same is true
NASA Astrophysics Data System (ADS)
Gonzalez, Silvia; Huddart, David; Israde-Alcántara, Isabel; Dominguez-Vazquez, Gabriela; Bischoff, James
2014-07-01
We report new stratigraphic, tephrochronology and dating results from the Tocuila Mammoth site in the Basin of Mexico. At the site there is evidence for a thin meteorite airburst layer dated between 10,878 and 10,707 cal BC at the onset of the Younger Dryas (YD) cool period. The Upper Toluca Pumice (UTP) tephra marker, caused by a Plinian eruption of the Nevado de Toluca volcano, dated from 10,666 to 10,612 cal BC, is above that layer. The eruption must have caused widespread environmental disruption in the region with evidence of extensive reworking and channelling by the Lake Texcoco shoreline and contributed to the widespread death and/or extinction of megafaunal populations, as suggested by earlier authors, but the new work reinforces the view that both catastrophic events must have caused large environmental disruption in a short time period of around two hundred years. There is no evidence for megafauna (mammoths, sabre toothed cats, camels, bison, glyptodonts) after the UTP volcanic event and subsequent lahars in the Basin of Mexico. At Tocuila, although there are some in situ tephra markers in nearshore lake sediments, such as the Great Basaltic Ash (GBA) and the UTP Ash, there is evidence of much reworking of several tephra populations in various combinations. The mammoth bone accumulation is reworked in a lahar sequence (volcanic mudflow) derived from several source sediments but associated with the major UTP Plinian eruption. Paleoindian populations were also present in the Basin of Mexico during the YD period, where several Paleoindian skeletons were found associated with the UTP ash deposits, e.g. Metro Man, Chimalhuacan Man and Tlapacoya Man.
Eliseev, V V; Rodionova, O M; Sapronov, N S; Selizarova, N O
2002-01-01
We studied the effects of uridine, uridine-5'-monophosphate (UMP), uridine-5'-diphosphate (UDP) and uridine-5'-triphosphate on contractility, coronary flow and heart rate in isolated perfused rat hearts under 60-minute regional ischemia of the left ventricle. All the compounds (50 mumol/l) induced a positive inotropic effect but had no effect on the heart rate. Uridine and UMP prevented the development of the contracture. UDP and especially UTP increased coronary flow. Probably, a protective effect of uridine and UMP is due to activation of myocardial glycogen synthesis while favourable effects of UDP and UTP on contractility and coronary flow are explained by their influence on P2U-receptors of cardiomyocytes. In addition, coronary dilatation induced by UDP and UTP promoted the reduction of the damaged zone.
COX-2 and Prostate Cancer Angiogenesis
2002-03-01
papilloma virus -18 ing cell nuclear antigen staining), but induced ap- immortalization of PIN cell areas of radical-pros- optosis (TdT-mediated dUTP...the COX-2 surrounding basal cells (75%).3cA human PIN cell inhibitor had no effect on proliferation (proliferat- line was established by human
Papadopoulou, Eleni; Haugen, Margaretha; Schjølberg, Synnve; Magnus, Per; Brunborg, Gunnar; Vrijheid, Martine; Alexander, Jan
2017-09-05
Cell phone use during pregnancy is a public health concern. We investigated the association between maternal cell phone use in pregnancy and child's language, communication and motor skills at 3 and 5 years. This prospective study includes 45,389 mother-child pairs, participants of the MoBa, recruited at mid-pregnancy from 1999 to 2008. Maternal frequency of cell phone use in early pregnancy and child language, communication and motor skills at 3 and 5 years, were assessed by questionnaires. Logistic regression was used to estimate the associations. No cell phone use in early pregnancy was reported by 9.8% of women, while 39%, 46.9% and 4.3% of the women were categorized as low, medium and high cell phone users. Children of cell phone user mothers had 17% (OR = 0.83, 95% CI: 0.77, 0.89) lower adjusted risk of having low sentence complexity at 3 years, compared to children of non-users. The risk was 13%, 22% and 29% lower by low, medium and high maternal cell phone use. Additionally, children of cell phone users had lower risk of low motor skills score at 3 years, compared to children of non-users, but this association was not found at 5 years. We found no association between maternal cell phone use and low communication skills. We reported a decreased risk of low language and motor skills at three years in relation to prenatal cell phone use, which might be explained by enhanced maternal-child interaction among cell phone users. No evidence of adverse neurodevelopmental effects of prenatal cell phone use was reported.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-31
... Floor broker that executes against the Book is not charged (i.e., it is free),\\10\\ both for a security... being assessed for the following intraday transactions: For a Floor broker discretionary e-Quote (``d...'') trading on the Exchange pursuant to a grant of unlisted trading privileges (``UTP''); \\3\\ \\3\\ See, e.g...
Regional Frequency Computation Users Manual.
1972-07-01
increment of flow used to prevent infinite logarithms for events with zero flow X = Mean logarithm of flow events N = Total years of record S = Unbiased...C LIBRARY 3’jr.RfUTINFES USEO--ALflGpSINvAB3 1002 c PRGRAM ~ SUBRflUTINES CR0UTpR,chfNN-SFE COt’MENTS I-N RNGEN 100 C REFERENCE TOl TAPE ? AT
Yang, Jing-Feng; Gao, Rong-Chun; Wu, Hai-Tao; Li, Peng-Fei; Hu, Xian-Shu; Zhou, Da-Yong; Zhu, Bei-Wei; Su, Yi-Cheng
2015-11-04
The sea cucumber body wall melting phenomenon occurs under certain circumstances, and the mechanism of this phenomenon remains unclear. This study investigated the apoptosis in the ultraviolet (UV)-induced sea cucumber melting phenomenon. Fresh sea cucumbers (Stichopus japonicus) were exposed to UV radiation for half an hour at an intensity of 0.056 mW/cm(2) and then held at room temperature for melting development. The samples were histologically processed into formalin-fixed paraffin-embedded tissues. The apoptosis of samples was analyzed with the terminal deoxynucleotidyl-transferase-mediated dUTP nick end-labeling (TUNEL) assay and cleaved caspase-3 immunohistochemistry. The emergence of TUNEL-positive cells speeds up between 0.5 and 2 h after UV irradiation. Cleaved caspase-3 positive cells were obviously detected in sample tissues immediately after the UV irradiation. These results demonstrated that sea cucumber melting induced by UV irradiation was triggered by the activation of caspase-3 followed by DNA fragmentation in sea cucumber tissue, which was attributed to apoptosis but was not a consequence of autolysis activity.
Fredholm, Bertil B; Assender, Jean W; Irenius, Eva; Kodama, Noriko; Saito, Naoaki
2003-06-01
1. The effect of adenosine analogues and of nucleotides, alone or in combination, on intracellular calcium, accumulation of inositol (1,4,5) trisphosphate (InsP3), and on activation of protein kinase C (PKC) was studied in DDT1 MF2 cells derived from a Syrian hamster myosarcoma. These cells were found to express mRNA for A1 and some as yet unidentified P2Y receptor(s). 2. Activation of either receptor type stimulated the production of InsP3 and raised intracellular calcium in DDT1 MF2 cells. Similarly, the A1 selective agonist N6-cyclopentyladenosine (CPA) increased PKC-dependent phosphorylation of the substrate MBP(4-14) and induced a PKC translocation to the plasma membrane as determined using [3H]-phorbol dibutyrate (PDBu) binding in DDT1 MF-2 cells. However, neither adenosine nor CPA induced a significant translocation of transiently transfected gamma-PKC-GFP from the cytosol to the cell membrane. In contrast to adenosine analogues, ATP and UTP also caused a rapid but transient translocation of gamma-PKC-GFP and activation of PKC. 3. Doses of the A1 agonist CPA and of ATP or UTP per se caused barely detectable increases in intracellular Ca2+ but when combined, they caused an almost maximal stimulation. Similarly, adenosine (0.6 microM) and UTP (or ATP, 2.5 microM), which per se caused no detectable translocation of either gamma- or epsilon-PKC-GFP, caused when combined a very clear-cut translocation of both PKC subforms, albeit with different time courses. These results show that simultaneous activation of P2Y and adenosine A1 receptors synergistically increases Ca2+ transients and translocation of PKC in DDT1 MF-2 cells. Since adenosine is rapidly formed by breakdown of extracellular ATP, such interactions may be biologically important.
Van Uffelen, Lora J; Worcester, Peter F; Dzieciuch, Matthew A; Rudnick, Daniel L; Colosi, John A
2010-04-01
Deep acoustic shadow-zone arrivals observed in the late 1990s in the North Pacific Ocean reveal significant acoustic energy penetrating the geometric shadow. Comparisons of acoustic data obtained from vertical line arrays deployed in conjunction with 250-Hz acoustic sources at ranges of 500 and 1000 km from June to November 2004 in the North Pacific, with simulations incorporating scattering consistent with the Garrett-Munk internal-wave spectrum, are able to describe both the energy contained in and vertical extent of deep shadow-zone arrivals. Incoherent monthly averages of acoustic timefronts indicate that lower cusps associated with acoustic rays with shallow upper turning points (UTPs), where sound-speed structure is most variable and seasonally dependent, deepen from June to October as the summer thermocline develops. Surface-reflected rays, or those with near-surface UTPs, exhibit less scattering due to internal waves than in later months when the UTP deepens. Data collected in November exhibit dramatically more vertical extension than previous months. The depth to which timefronts extend is a complex combination of deterministic changes in the depths of the lower cusps as the range-average profiles evolve with seasonal change and of the amount of scattering, which depends on the mean vertical gradients at the depths of the UTPs.
30 CFR 77.701-3 - Grounding wires; capacity.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Grounding wires; capacity. 77.701-3 Section 77... MINES Grounding § 77.701-3 Grounding wires; capacity. Where grounding wires are used to ground metallic sheaths, armors, conduits, frames, casings, and other metallic enclosures, such grounding wires will be...
30 CFR 77.701-3 - Grounding wires; capacity.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Grounding wires; capacity. 77.701-3 Section 77... MINES Grounding § 77.701-3 Grounding wires; capacity. Where grounding wires are used to ground metallic sheaths, armors, conduits, frames, casings, and other metallic enclosures, such grounding wires will be...
Kimura, T; Nishizawa, T; Yoshimizu, M; De Clercq, E
1988-01-01
The highly potent and selective anti-herpesvirus agent, (E)-5-(2-bromovinyl)-2'deoxyuridine (BVdU), was examined for its inhibitory effect on the salmonid herpesviruses Oncorhynchus masou virus (OMV) and Herpesvirus salmonis (H. salmonis). Minimum inhibitory concentrations (MIC) of BVdU for OMV and H. salmonis were 1.25 and 3.0 micrograms/ml, respectively; these values were equal to or higher than those obtained for acyclovir or cytarabine. OMV DNA polymerase activity was reduced in a dose-dependent fashion by BVdU 5'-triphosphate (BVdUTP) within the concentration range of 3 to 30 microM. However, BVdUTP could also be substituted for the natural substrate, TTP, in the OMV DNA polymerase assay. It is postulated that the inhibitory action of BVdU on the salmonid herpesviruses is more or less similar to that on other herpesviruses and resides with respect to the inhibition of the virus DNA polymerase activity as well as incorporation of BVdU into the viral DNA.
Biosynthesis of sulfoquinovosyldiacylglycerol in higher plants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kleppinger-Sparace, K.F.; Mudd, J.B.
1987-07-01
Intact spinach chloroplasts incorporated /sup 35/SO/sub 4//sup 2 -/ into sulfoquinovosyldiacylglycerol in the dark at rates equivalent to those previously reported for illuminated chloroplasts provided that either ATP itself or an ATP-generating system was added. No additional reductant was necessary for SQDG synthesis by chloroplasts. The optimal concentration of ATP was between 2 and 3 millimolar. Rates of synthesis up to 2.6 nanomoles per milligram chlorophyll per hour were observed. UTP, GTP, and CTP could not substitute for ATP. Incubation of UTP with ATP (1:1) stimulated synthesis of sulfoquinovosyldiacylglycerol. No additional stimulation of the reaction was observed upon addition ofmore » other nucleoside triphosphates with ATP. For the generation of ATP in the chloroplast, addition of dihydroxyacetone phosphate alone did not promote synthesis of sulfoquinovosyldiacylglycerol, but in combination with inorganic phosphate and oxaloacetate, rates of synthesis up to 3.2 nanomoles per milligram chlorophyll per hour were observed. Dark synthesis was optimal in the presence of 2 millimolar dihydroxyacetone phosphate, 2 millimolar oxaloacetate, and 1 millimolar KH/sub 2/PO/sub 4/.« less
Torque Generation Mechanism of F1-ATPase upon NTP Binding
Arai, Hidenobu C.; Yukawa, Ayako; Iwatate, Ryu John; Kamiya, Mako; Watanabe, Rikiya; Urano, Yasuteru; Noji, Hiroyuki
2014-01-01
Molecular machines fueled by NTP play pivotal roles in a wide range of cellular activities. One common feature among NTP-driven molecular machines is that NTP binding is a major force-generating step among the elementary reaction steps comprising NTP hydrolysis. To understand the mechanism in detail,in this study, we conducted a single-molecule rotation assay of the ATP-driven rotary motor protein F1-ATPase using uridine triphosphate (UTP) and a base-free nucleotide (ribose triphosphate) to investigate the impact of a pyrimidine base or base depletion on kinetics and force generation. Although the binding rates of UTP and ribose triphosphate were 103 and 106 times, respectively, slower than that of ATP, they supported rotation, generating torque comparable to that generated by ATP. Affinity change of F1 to UTP coupled with rotation was determined, and the results again were comparable to those for ATP, suggesting that F1 exerts torque upon the affinity change to UTP via rotation similar to ATP-driven rotation. Thus, the adenine-ring significantly enhances the binding rate, although it is not directly involved in force generation. Taking into account the findings from another study on F1 with mutated phosphate-binding residues, it was proposed that progressive bond formation between the phosphate region and catalytic residues is responsible for the rotation-coupled change in affinity. PMID:24988350
Hardell, Lennart; Carlberg, Michael; Hansson Mild, Kjell
2006-09-01
To study the use of cellular and cordless telephones and the risk for malignant brain tumours. Two case-control studies on malignant brain tumours diagnosed during 1997-2003 included answers from 905 (90%) cases and 2,162 (89%) controls aged 20-80 years. We present pooled analysis of the results in the two studies. Cumulative lifetime use for >2,000 h yielded for analogue cellular phones odds ratio (OR)=5.9, 95% confidence interval (CI)=2.5-14, digital cellular phones OR=3.7, 95% CI=1.7-7.7, and for cordless phones OR=2.3, 95% CI=1.5-3.6. Ipsilateral exposure increased the risk for malignant brain tumours; analogue OR=2.1, 95% CI=1.5-2.9, digital OR=1.8, 95% CI=1.4-2.4, and cordless OR=1.7, 95% CI=1.3-2.2. For high-grade astrocytoma using >10 year latency period analogue phones yielded OR=2.7, 95% CI=1.8-4.2, digital phones OR=3.8, 95% CI=1.8-8.1, and cordless phones OR=2.2, 95% CI=1.3-3.9. In the multivariate analysis all phone types increased the risk. Regarding digital phones OR=3.7, 95% CI=1.5-9.1 and cordless phones OR=2.1, 95% CI=0.97-4.6 were calculated for malignant brain tumours for subjects with first use use <20 years of age, higher than in older persons. Increased risk was obtained for both cellular and cordless phones, highest in the group with >10 years latency period.
On the association between glioma, wireless phones, heredity and ionising radiation.
Carlberg, Michael; Hardell, Lennart
2012-09-01
We performed two case-control studies on brain tumours diagnosed during 1 January 1997 to 30 June 2000 and 1 July 2000 to 31 December 2003, respectively. Living cases and controls aged 20-80 years were included. An additional study was performed on deceased cases with a malignant brain tumour using deceased controls. Pooled results for glioma yielded for ipsilateral use of mobile phone odds ratio (OR)=2.9, 95% confidence interval (CI)=1.8-4.7 in the >10 years latency group. The corresponding result for cordless phone was OR=3.8, 95% CI=1.8-8.1. OR increased statistically significant for cumulative use of wireless phones per 100h and per year of latency. For high-grade glioma ipsilateral use of mobile phone gave OR=3.9, 95% CI=2.3-6.6 and cordless phone OR=5.5, 95% CI=2.3-13 in the >10 years latency group. Heredity for brain tumour gave OR=3.4, 95% CI=2.1-5.5 for glioma. There was no interaction with use of wireless phones. X-ray investigation of the head gave overall OR=1.3, 95% CI=1.1-1.7 for glioma without interaction with use of wireless phones or heredity. In conclusion use of mobile and cordless phone increased the risk for glioma with highest OR for ipsilateral use, latency >10 years and third tertile of cumulative use in hours. In total, the risk was highest in the age group <20 years for first use of a wireless phone. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Mobile Phone Dependence, Social Support and Impulsivity in Chinese University Students.
Mei, Songli; Chai, Jingxin; Wang, Shi-Bin; Ng, Chee H; Ungvari, Gabor S; Xiang, Yu-Tao
2018-03-13
This study examined the frequency of mobile phone dependence in Chinese university students and explored its association with social support and impulsivity. Altogether, 909 university students were consecutively recruited from a large university in China. Mobile phone use, mobile phone dependence, impulsivity, and social support were measured with standardized instruments. The frequency of possible mobile phone use and mobile phone dependence was 78.3% and 7.4%, respectively. Multinomial logistic regression analyses revealed that compared with no mobile phone dependence, possible mobile phone dependence was significantly associated with being male ( p = 0.04, OR = 0.7, 95% CI: 0.4-0.98), excessive mobile phone use ( p < 0.001, OR = 1.2, 95% CI: 1.09-1.2), and impulsivity ( p < 0.001, OR = 1.05, 95% CI: 1.03-1.06), while mobile phone dependence was associated with length of weekly phone use ( p = 0.01, OR = 2.5, 95% CI: 1.2-5.0), excessive mobile phone use ( p < 0.001, OR = 1.3, 95% CI: 1.2-1.4), and impulsivity ( p < 0.001, OR = 1.08, 95% CI: 1.05-1.1). The frequency of possible mobile phone dependence and mobile phone dependence was high in this sample of Chinese university students. A significant positive association with impulsivity was found, but not with social support.
Modulation of Ionic Channel Function by Protein Phosphorylation
1992-11-12
were prepared from the cloned cDNAs using the SP6 RNA promoter/polymerase system (32) with capping accomplished by priming with cap analogues (33...triphosphate (ATP), cytidine triphosphate (CTP) and uridine triphosphate (UTP) [ct-32p]UTP at 80 Cilmmol; 0.1 mM GTP; 0.5 mM diguanosinetriphosphate; 200 g.g/ml...state NMR spectroscopy . J. Biomol. NMR 1:167-173. (1991). Tomich, J.M., A. Grove, T. Iwamoto, S. Marrer, M.S. Montal and M. Montal. Design principles
Kumar, B Vinod; Hobani, Yahya Hasan; Abdulhaq, Ahmed; Jerah, Ahmed Ali; Hakami, Othman M; Eltigani, Magdeldin; Bidwai, Anil K
2014-01-01
Mobile phones contaminated with bacteria may act as fomites. Antibiotic resistant bacterial contamination of mobile phones of inpatients was studied. One hundred and six samples were collected from mobile phones of patients admitted in various hospitals in Jazan province of Saudi Arabia. Eighty-nine (83.9%) out of 106 mobile phones were found to be contaminated with bacteria. Fifty-two (49.0%) coagulase-negative Staphylococcus, 12 (11.3%) Staphylococcus aureus, 7 (6.6%) Enterobacter cloacae, 3 (2.83%) Pseudomonas stutzeri, 3 (2.83%) Sphingomonas paucimobilis, 2 (1.8%) Enterococcus faecalis and 10 (9.4%) aerobic spore bearers were isolated. All the isolated bacteria were found to be resistant to various antibiotics. Hence, regular disinfection of mobile phones of hospital inpatients is advised.
Phone use and crashes while driving: A representative survey of drivers in two Australian states.
McEvoy, Suzanne P; Stevenson, Mark R; Woodward, Mark
To explore the use and effects of using mobile phones while driving. Cross-sectional survey. New South Wales and Western Australia, 20 October to 7 November 2003. 1347 licensed drivers aged 18 to 65 years. Data were weighted to reflect the corresponding driving population in each state. Mobile phone use while driving (hand-held, hands-free and text messaging); adverse effects of use. While driving, an estimated 57.3% +/- 1.5% of drivers have ever used a mobile phone and 12.4% +/- 1.0% have written text messages. Men, younger drivers and metropolitan residents were more likely to use a phone while driving and to report a higher frequency of use. Enforcement of hand-held phone restrictions was perceived to be low (69.0% +/- 1.5%) and an estimated 39.4% +/- 2.1% of people who phone while driving use a hand-held phone. Half of all drivers (50.1% +/- 1.6%) did not agree with extending the ban to include hands-free phones. Among drivers aged 18-65 years in NSW and WA, an estimated 45 800 +/- 16 466 (0.9% +/- 0.3%) have ever had a crash while using a mobile phone and, in the past year, 146 762 +/- 26 856 (3.0% +/- 0.6%) have had to take evasive action to avoid a crash because of their phone use. Phone use while driving is prevalent and can result in adverse consequences, including crashes. Despite legislation, a significant proportion of drivers continue to use hand-held mobile phones while driving. Enhanced enforcement is needed.
Comparing handheld and hands-free cell phone usage behaviors while driving.
Soccolich, Susan A; Fitch, Gregory M; Perez, Miguel A; Hanowski, Richard J
2014-01-01
The goal of this study was to compare cell phone usage behaviors while driving across 3 types of cell phones: handheld (HH) cell phones, portable hands-free (PHF) cell phones, and integrated hands-free (IHF) cell phones. Naturalistic driving data were used to observe HH, PHF, and IHF usage behaviors in participants' own vehicles without any instructions or manipulations by researchers. In addition to naturalistic driving data, drivers provided their personal cell phone call records. Calls during driving were sampled and observed in naturalistically collected video. Calls were reviewed to identify cell phone type used for, and duration of, cell phone subtasks, non-cell phone secondary tasks, and other use behaviors. Drivers in the study self-identified as HH, PHF, or IHF users if they reported using that cell phone type at least 50% of the time. However, each sampled call was classified as HH, PHF, or IHF if the talking/listening subtask was conducted using that cell phone type, without considering the driver's self-reported group. Drivers with PHF or IHF systems also used HH cell phones (IHF group used HH cell phone in 53.2% of the interactions, PHF group used HH cell phone for 55.5% of interactions). Talking/listening on a PHF phone or an IHF phone was significantly longer than talking/listening on an HH phone (P <.05). HH dialing was significantly longer in duration than PHF or IHF begin/answer tasks. End phone call task for HH phones was significantly longer in duration than the end phone call task for PHF and IHF phones. Of all the non-cell phone-related secondary tasks, eating or drinking was found to occur significantly more often during IHF subtasks (0.58%) than in HH subtasks (0.15%). Drivers observed to reach for their cell phone mostly kept their cell phone in the cup holder (36.3%) or in their seat or lap (29.0% of interactions); however, some observed locations may have required drivers to move out of position. Hands-free cell phone technologies reduce the duration of cell phone visual-manual tasks compared to handheld cell phones. However, drivers with hands-free cell phone technologies available to them still choose to use handheld cell phones to converse or complete cell phone visual-manual tasks for a noteworthy portion of interactions.
Cell Phone Calls in the Operating Theater and Staff Distractions: An Observational Study.
Avidan, Alexander; Yacobi, Galel; Weissman, Charles; Levin, Phillip D
2017-01-09
Cell phones are the primary communication tool in our institution. There are no restrictions on their use in the operating rooms. The goal of this study was to evaluate the extent of cell phone use in the operating rooms during elective surgery and to evaluate whether they cause staff distractions. The following data on cell phone use were recorded anonymously: number of incoming and outgoing cell phone calls, duration of cell phone calls and their content (patient related, work related, private), who was distracted by the cell phone calls, and duration of distractions. We made observations during 52 surgeries. There were 205 cell phone calls, 197 (96.1%; median, 3 per surgery; interquartile range, 2-5) incoming and 8 (3.9%) outgoing. Incoming calls were answered on 110 (55.8%) of 197 (median, 2; interquartile range, 1-3) occasions. The mean duration of incoming calls (64 ± 40 seconds) was shorter than those of the outgoing calls (137 ± 242 seconds, P < 0.001). During 29 (14.7%) of 197 incoming calls, 30 staff distractions occurred. Distractions were caused mainly for surgeons talking on their cell phones (24/30, 80.0%). The mean duration of the distractions was 43.6 ± 22.3 seconds. During all 8 outgoing calls, no other staff members were distracted. The number of cell phone calls in the operating rooms during elective surgery was lower than expected and caused short-lived distractions mainly to the operating surgeons. We recommend that operating surgeons turn off their cell phones before surgery.
Functional implications from the Cid1 poly(U) polymerase crystal structure.
Munoz-Tello, Paola; Gabus, Caroline; Thore, Stéphane
2012-06-06
In eukaryotes, mRNA degradation begins with poly(A) tail removal, followed by decapping, and the mRNA body is degraded by exonucleases. In recent years, the major influence of 3'-end uridylation as a regulatory step within several RNA degradation pathways has generated significant attention toward the responsible enzymes, which are called poly(U) polymerases (PUPs). We determined the atomic structure of the Cid1 protein, the founding member of the PUP family, in its UTP-bound form, allowing unambiguous positioning of the UTP molecule. Our data also suggest that the RNA substrate accommodation and product translocation by the Cid1 protein rely on local and global movements of the enzyme. Supplemented by point mutations, the atomic model is used to propose a catalytic cycle. Our study underlines the Cid1 RNA binding properties, a feature with critical implications for miRNAs, histone mRNAs, and, more generally, cellular RNA degradation. Copyright © 2012 Elsevier Ltd. All rights reserved.
Mobile Phone Dependence, Social Support and Impulsivity in Chinese University Students
Mei, Songli; Chai, Jingxin; Wang, Shi-Bin; Ng, Chee H.; Ungvari, Gabor S.; Xiang, Yu-Tao
2018-01-01
This study examined the frequency of mobile phone dependence in Chinese university students and explored its association with social support and impulsivity. Altogether, 909 university students were consecutively recruited from a large university in China. Mobile phone use, mobile phone dependence, impulsivity, and social support were measured with standardized instruments. The frequency of possible mobile phone use and mobile phone dependence was 78.3% and 7.4%, respectively. Multinomial logistic regression analyses revealed that compared with no mobile phone dependence, possible mobile phone dependence was significantly associated with being male (p = 0.04, OR = 0.7, 95% CI: 0.4–0.98), excessive mobile phone use (p < 0.001, OR = 1.2, 95% CI: 1.09–1.2), and impulsivity (p < 0.001, OR = 1.05, 95% CI: 1.03–1.06), while mobile phone dependence was associated with length of weekly phone use (p = 0.01, OR = 2.5, 95% CI: 1.2–5.0), excessive mobile phone use (p < 0.001, OR = 1.3, 95% CI: 1.2–1.4), and impulsivity (p < 0.001, OR = 1.08, 95% CI: 1.05–1.1). The frequency of possible mobile phone dependence and mobile phone dependence was high in this sample of Chinese university students. A significant positive association with impulsivity was found, but not with social support. PMID:29533986
Vinod Kumar, B.; Hobani, Yahya Hasan; Abdulhaq, Ahmed; Jerah, Ahmed Ali; Hakami, Othman M.; Eltigani, Magdeldin; Bidwai, Anil K.
2014-01-01
Mobile phones contaminated with bacteria may act as fomites. Antibiotic resistant bacterial contamination of mobile phones of inpatients was studied. One hundred and six samples were collected from mobile phones of patients admitted in various hospitals in Jazan province of Saudi Arabia. Eighty-nine (83.9%) out of 106 mobile phones were found to be contaminated with bacteria. Fifty-two (49.0%) coagulase-negative Staphylococcus, 12 (11.3%) Staphylococcus aureus, 7 (6.6%) Enterobacter cloacae, 3 (2.83%) Pseudomonas stutzeri, 3 (2.83%) Sphingomonas paucimobilis, 2 (1.8%) Enterococcus faecalis and 10 (9.4%) aerobic spore bearers were isolated. All the isolated bacteria were found to be resistant to various antibiotics. Hence, regular disinfection of mobile phones of hospital inpatients is advised. PMID:25292217
Brady, R R; Hunt, A C; Visvanathan, A; Rodrigues, M A; Graham, C; Rae, C; Kalima, P; Paterson, H M; Gibb, A P
2011-06-01
Healthcare workers' mobile phones provide a reservoir of bacteria known to cause nosocomial infections. UK National Health Service restrictions on the utilization of mobile phones within hospitals have been relaxed; however, utilization of these devices by inpatients and the risk of cross-contamination are currently unknown. Here, we examine demographics and characteristics of mobile phone utilization by inpatients and phone surface microbial contamination. One hundred and two out of 145 (70.3%) inpatients who completed a questionnaire detailing their opinions and utilization of mobile phones, also provided their mobile phones for bacteriological analysis and comparative bacteriological swabs from their nasal cavities; 92.4% of patients support utilization of mobile phones by inpatients; indeed, 24.5% of patients stated that mobile phones were vital to their inpatient stay. Patients in younger age categories were more likely to possess a mobile phone both inside and outside hospital (p <0.01) but there was no gender association. Eighty-six out of 102 (84.3%) patients' mobile phone swabs were positive for microbial contamination. Twelve (11.8%) phones grew bacteria known to cause nosocomial infection. Seven (6.9%) phones and 32 (31.4%) nasal swabs demonstrated Staphylococcus aureus contamination. MSSA/MRSA contamination of phones was associated with concomitant nasal colonization. Patient utilization of mobile phones in the clinical setting is popular and common; however, we recommend that patients are educated by clear guidelines and advice on inpatient mobile phone etiquette, power charging safety, regular cleaning of phones and hand hygiene, and advised not to share phones or related equipment with other inpatients in order to prevent transmission of bacteria. 2011 The Authors. Clinical Microbiology and Infection; 2011 European Society of Clinical Microbiology and Infectious Diseases.
Tight Placement of Erich Arch Bar While Avoiding Wire Fatigue Failure.
Kirk, Daniel; Whitney, Joseph; Shafer, David; Song, Liansheng
2016-03-01
To determine the number of wire twists needed to acquire ideal Erich arch bar tightness before wire fatigue failure (fracture) in relation to different distances and angles at which different gauge wires are grasped to provide information to improve the efficiency of arch bar application. This study mimicked surgical placement of arch bars with 24- and 26-gauge wires. The number of twists to tightness and failure was evaluated when the wire distance between the arch bar and wire holder tip changed (5 vs 10 mm) and when the degree at which the wire was held relative to the tooth axis was changed (45° vs 90°). A wire shearing test also was used to investigate the fatigability of wires tightened under these same conditions. Wires twisted to tightness, past tightness, and after shearing test movements were visualized with electron microscopy. For 24-gauge wire held at 5 mm, 2.6 to 2.8 twists were needed for wire tightness, with failure after 1.7 to 1.9 twists past tightness; for 24-gauge wire held at 10 mm, 4.4 to 4.9 twists produced tightness, with failure after 2.3 to 2.9 twists past tightness. For 26-gauge wire held at 5 mm, 3.3 to 3.5 twists provided tightness, with 1.6 to 1.8 twists past tightness causing failure; for 26-gauge wire held at 10 mm, 5.1 to 5.5 twists produced tightness, with 3.1 to 3.7 twists past tightness causing failure. At a 45° angle, the wire tightened with fewer twists and showed more resistance to failure with twists past tightness compared with 90° using 24- and 26-gauge wires. In contrast, 24-gauge wire held at a 5-mm distance showed the opposite result, with decreased resistance to failure at the 45° angle. However, the differences were not statistically meaningful. Scanning election microscopy showed no wire fatigue for either angle for 26-gauge wire held at a 5-mm distance and twisted to tightness. After overtightening and oscillation, the 90° angle trials showed fatigue, whereas the 45° angle trials did not. Holding a 24-gauge wire at 45° to the tooth axis is recommended owing to fewer twists to tightness and more resistance to failure. A 5-mm grasping distance is recommended for experienced surgeons owing to fewer twists to tightness, whereas a 10-mm grasping distance is recommended for novice surgeons owing to a greater tolerance for over-twisting before failure. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
The effects of purine compounds on the isolated aorta of the frog Rana temporaria.
Knight, G. E.; Burnstock, G.
1996-01-01
1. In the isolated aorta of the frog, Rana temporaria, adenosine concentration-dependently, endothelium-independently relaxed adrenaline pre-constricted vessels. None of the adenosine analogues including D-5'-(N-ethylcarboxamide) adenosine (NECA), R- and S-N6-(2-phenylisopropyl) adenosine (R-and S-PIA) and 2-chloroadenosine (2-CA), or the more selective A1, A2 and A3 agonists cyclopentyladenosine (CPA), CGS 21680 and N6-(3-iodobenzyl) adenosine-5'-N-methylcarboxamide (IB-MECA) respectively, had any effect. 2. The non-selective adenosine antagonist, 8-p-sulphophenyl-theophylline (8-pSPT; 30 microM) failed to inhibit adenosine relaxations, as did NG-nitro-L-arginine methyl ester (L-NAME; 0.1 mM) and indomethacin (30 microM). 3. Adenosine 5'-triphosphate (ATP), alpha, beta-methylene ATP (alpha, beta-MeATP), beta, gamma-methylene ATP (beta, gamma-MeATP), 2-methylthio ATP (2-MeSATP) and uridine 5'-triphosphate (UTP) all concentration-dependently contracted the frog aorta. ATP and alpha, beta-MeATP were equipotent and more potent than UTP and beta, gamma-MeATP; 2-MeSATP had little activity. 4. The P2-purinoceptor antagonist, suramin (0.1 mM) inhibited contractions to alpha, beta-MeATP but not to ATP. Pyridoxalphosphate-6-azophenyl-2',4'-disulphonic acid (PPADS; 30 microM) also inhibited contractions to alpha, beta-MeATP but not to ATP. Contractions to ATP were, however, inhibited by indomethacin (30 microM). 5. In conclusion, in the frog aorta there appears to be a novel subclass of P1-purinoceptor mediating vasodilatation, although like the A3 subclass it is not blocked by methylxanthines; a P2-purinoceptor mediates vasconstriction which resembles a P2x subtype, based on the agonist potency of alpha, beta-MeATP being more potent than 2-MeSATP (UTP has moderate activity) and PPADS is an effective antagonist. There is no evidence for the presence of a P2y-purinoceptor, mediating vasodilatation, in this preparation. PMID:8851504
Wang, Hong-mei; Wang, Bang-kang; Ren, Chao-chao; Bai, Yu-xing
2011-03-01
To investigate the mechanical properties of Ni-Ti wires with direct electric resistance heat treatment (DERHT) method in three-point bending tests. Two superelastic Ni-Ti wires (wire A: Smart SE, wire B: SENTALLOY SE, 0.406 mm × 0.559 mm) and 2 heat-actived Ni-Ti wires (wire C: Smart SM, wire D: L&H TITAN, 0.406 mm × 0.559 mm) were selected. They were heat-treated using the DERHT method by a controlled electric current (6.36 A) applied for different period of time [0 (control), 1.0, 1.5, 2.0, 2.5 seconds). Then, a three-point bending test was performed under controlled temperature (37°C) to examine the relationships between the deflection and the load in the bending of wires. After DERHT treatment, the plateau in the force-deflection curve of superelastic Ni-Ti wires and heat-activated Ni-Ti wires were increased. When the wires were heated for 2.0 seconds and deflected to 1.5 mm, the loading force of A, B, C and D Ni-Ti wires increased from (3.85 ± 0.11), (3.62 ± 0.07), (3.28 ± 0.09), (2.91 ± 0.23) N to (4.33 ± 0.07), (4.07 ± 0.05), (4.52 ± 0.08), (3.27 ± 0.15) N respectively. DERHT method is very convenient for clinical use. It is possible to change the arch form and superelastic force of NiTi wires. The longer the heating time is, the more the superelastic characteristics of the wires are altered.
Liaw, Yu-Cheng; Su, Yu-Yu M; Lai, Yu-Lin; Lee, Shyh-Yuan
2007-05-01
Stress-induced martensite formation with stress hysteresis that changes the elasticity and stiffness of nickel-titanium (Ni-Ti) wire influences the sliding mechanics of archwire-guided tooth movement. This in-vitro study investigated the frictional behavior of an improved superelastic Ni-Ti wire with low-stress hysteresis. Improved superelastic Ni-Ti alloy wires (L & H Titan, Tomy International, Tokyo, Japan) with low-stress hysteresis were examined by using 3-point bending and frictional resistance tests with a universal test machine at a constant temperature of 35 degrees C, and compared with the former conventional austenitic-active superelastic Ni-Ti wires (Sentalloy, Tomy International). Wire stiffness levels were derived from differentiation of the polynomial regression of the unloading curves, and values for kinetic friction were measured at constant bending deflection distances of 0, 2, 3, and 4 mm, respectively. Compared with conventional Sentalloy wires, the L & H Titan wire had a narrower stress hysteresis including a lower loading plateau and a higher unloading plateau. In addition, L & H Titan wires were less stiff than the Sentalloy wires during most unloading stages. Values of friction measured at deflections of 0, 2, and 3 mm were significantly (P <.05) increased in both types of wire. However, they showed a significant decrease in friction from 3 to 4 mm of deflection. L & H Titan wires had less friction than Sentalloy wires at all bending deflections (P <.05). Stress-induced martensite formation significantly reduced the stiffness and thus could be beneficial to decrease the binding friction of superelastic Ni-Ti wires during sliding with large bending deflections. Austenitic-active alloy wires with low-stress hysteresis and lower stiffness and friction offer significant potential for further investigation.
Hurt, E; Zulewska, J; Newbold, M; Barbano, D M
2010-12-01
The production of serum protein (SP) and micellar casein from skim milk can be accomplished using microfiltration (MF). Potential commercial applications exist for both SP and micellar casein. Our research objective was to determine the total SP removal and SP removal for each stage, and the composition of retentates and permeates, for a 3×, continuous bleed-and-feed, 3-stage, uniform transmembrane pressure (UTP) system with 0.1-μm ceramic membranes, when processing pasteurized skim milk at 50°C with 2 stages of water diafiltration. For each of 4 replicates, about 1,100 kg of skim milk was pasteurized (72°C, 16s) and processed at 3× through the UTP MF system. Retentate from stage 1 was cooled to <4°C and stored until the next processing day, when it was diluted with reverse osmosis water back to a 1× concentration and again processed through the MF system (stage 2) to a 3× concentration. The retentate from stage 2 was stored at <4°C, and, on the next processing day, was diluted with reverse osmosis water back to a 1× concentration, before running through the MF system at 3× for a total of 3 stages. The retentate and permeate from each stage were analyzed for total nitrogen, noncasein nitrogen, and nonprotein nitrogen using Kjeldahl methods; sodium dodecyl sulfate-PAGE analysis was also performed on the retentates from each stage. Theoretically, a 3-stage, 3× MF process could remove 97% of the SP from skim milk, with a cumulative SP removal of 68 and 90% after the first and second stages, respectively. The cumulative SP removal using a 3-stage, 3× MF process with a UTP system with 0.01-μm ceramic membranes in this experiment was 64.8 ± 0.8, 87.8 ± 1.6, and 98.3 ± 2.3% for the first, second, and third stages, respectively, when calculated using the mass of SP removed in the permeate of each stage. Various methods of calculation of SP removal were evaluated. Given the analytical limitations in the various methods for measuring SP removal, calculation of SP removal based on the mass of SP in the skim milk (determined by Kjeldahl) and the mass SP present in all of the permeate produced by the process (determined by Kjeldahl) provided the best estimate of SP removal for an MF process. Copyright © 2010 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
2015-09-04
aluminum wire into an anodized aluminum oxide ( AAO ) shell (step 1, Fig. 1, A and B). The thickness of the resulting AAO shell can be...regulated by changing the anodizing time. Thus, a prepared wire with aluminum core and AAO shell ( AAO wire) was then used as a template for a single-step...showing the synthesis and microstructures of a 3D graphene-RACNT fiber. (A) Aluminum wire. (B) Surface anodized aluminum wire ( AAO wire). (C)
Digital Systems Validation Handbook. Volume 2
1989-02-01
power. 2. A grid of wires, solid sheet, or foil. 3. A wire from circuit to grounding block or case. 4. A wire from circuit to structure. 5. Shield...RETURN. (11) 1. Structure, for power, fault, and "discrete" circuits. 2. A grid of wires, solid sheet, or foil. 3. A wire from circuit load back to...TV (14) Television TWTD (13) Thin Wire Time Domain TX (5) Transmit U.K. (13,141 United Kingdom U.S. (14) United States UART (15) Universal Asynchronous
Mechanistic studies of ribonucleoside triphosphate reductase from Lactobacillus leichmannii
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harris, G.M.
1984-01-01
The mechanism of action of the adenosylcobalamin (AdoCbl)-dependent ribonucleoside triphosphate reductase (RTPR) was investigated using isotope effect and substrate specificity studies. These experiments were conducted on RTPR purified by a new method from Lactobacillus leichmannii. Isotope effect studies using (3{prime}-{sup 3}H)UTP and (3{prime}-{sup 3}H)ATP demonstrated that the 3{prime} C-H bond of the nucleotide is cleaved in order to cleave the 2{prime} C-OH bond. AdoCbl does not act as a direct H abstractor from the 3{prime} position of the substrate, but instead is thought to act as a radical chain initiator to generate an amino acid radical on the enzyme. Furthermore » support for this enzyme mediated cleavage of the 3{prime} C-H bond of the nucleotide and the novel role of AdoCbl came from studies using (3{prime}{sup 3}H)2{prime}-chloro-2{prime}-deoxyuridine 5{prime}-triphosphate ((3{prime}-{sup 3}H)CIUTP). Evidence is presented that during the course of this reaction, the {sup 3}H abstracted from the 3{prime} position of (3{prime}-{sup 3}H)CIUTP was either exchanged with the solvent or returned to the {beta} face of the 2{prime} position to produce (2{prime}{sup 3}H)-2{prime}-deoxy-3{prime}-ketoUTP. This result demonstrates that RTPR is capable of catalyzing a rearrangement reaction. The significance of the RTPR-catalyzed rearrangement with respect to the AdoCbl-dependent enzymes which catalyze rearrangements is discussed.« less
Kaplan, A D; Kilkenny, D M; Hill, D J; Dixon, S J
1996-11-01
Extracellular nucleotides interact with specific cell surface receptors to mediate a variety of biological responses, including elevation of the cytosolic free Ca2+ concentration ([Ca2+]i) in a number of cell types. Although extracellular ATP has been shown to affect chondrocyte function, the underlying mechanisms are poorly understood. In the present study, we investigated whether Ca2+-mobilizing purinoceptors are present on sheep chondrocytes. Chondrocytes were isolated from the proximal tibial growth plate of day 120-130 sheep fetuses. Early passage cells were loaded with indo-1 or fluo-3, and [Ca2+]i was monitored by fluorescence spectrophotometry. ATP (0.3-100 microM) induced transient elevation of [Ca2+]i, lasting approximately 1 min. Half-maximal elevation of [Ca2+]i was observed at an ATP concentration of 5.0 +/- 0.2 microM. Responses were still observed in the absence of extracellular Ca2+, and were abolished by pretreatment with thapsigargin, consistent with the release of Ca2+ from intracellular stores. Several nucleotides were tested for their ability to elevate [Ca2+]i. In order of potency, these were UTP approximately ATP > ADP approximately 2-methylthio-ATP. No responses were elicited by benzoylbenzoic-ATP, a P2Z-selective agonist; alpha,beta-methylene-ATP, an agonist selective for certain P2X purinoceptors; AMP; adenosine; or pyrophosphate (all at 100 microM), demonstrating specificity. Taken together, these data indicate that nucleotides elevate [Ca2+]i in chondrocytes through interaction with the P2U purinoceptor subtype. Although pretreatment with pertussis toxin virtually abolished the Ca2+ response to lysophosphatidic acid, the response to UTP was relatively insensitive, suggesting that P2U purinoceptors are not linked to a pertussis toxin-sensitive G protein in chondrocytes. In contrast, the Ca2+ response to UTP was markedly inhibited by the biologically active phorbol ester 12-O-tetradecanoyl-beta-phorbol 13-acetate, but not by the inactive control compound 4 alpha-phorbol 12,13-didecanoate, suggesting that a 12-O-tetradecanoyl-beta-phorbol 13-acetate-sensitive isoform of protein kinase C regulates P2U purinoceptor signaling in these cells. UTP (10 microM) enhanced the proliferative response to basic fibroblast growth factor. The response to basic fibroblast growth factor was also enhanced by ATP, but not by 2-methylthio-ATP, consistent with involvement of P2U purinoceptors. Nucleotides released during trauma, inflammation, or cell death may act through P2U purinoceptors to regulate chondrocyte function in an autocrine or paracrine manner.
NASA Astrophysics Data System (ADS)
Sundaram, Rajyashree; Yamada, Takeo; Hata, Kenji; Sekiguchi, Atsuko
2018-04-01
We present the influence of density, structural regularity, and purity of carbon nanotube wires (CNTWs) used as Cu electrodeposition templates on fabricating homogeneous high-electrical performance CNT-Cu wires lighter than Cu. We show that low-density CNTWs (<0.6 g/cm3 for multiwall nanotube wires) with regular macro- and microstructures and high CNT content (>90 wt %) are essential for making homogeneous CNT-Cu wires. These homogeneous CNT-Cu wires show a continuous Cu matrix with evenly mixed nanotubes of high volume fractions (˜45 vol %) throughout the wire-length. Consequently, the composite wires show densities ˜5.1 g/cm3 (33% lower than Cu) and electrical conductivities ˜6.1 × 104 S/cm (>100 × CNTW conductivity). However, composite wires from templates with higher densities or structural inconsistencies are non-uniform with discontinuous Cu matrices and poor CNT/Cu mixing. These non-uniform CNT-Cu wires show conductivities 2-6 times lower than the homogeneous composite wires.
Jones, R P; Conway, D H
2005-08-01
Electromagnetic interference produced by wireless communication can affect medical devices and hospital policies exist to address this risk. During the transfer of ventilated patients, these policies may be compromised by essential communication between base and receiving hospitals. Local wireless networks (e.g. Bluetooth) may reduce the 'spaghetti syndrome' of wires and cables seen on intensive care units, but also generate electromagnetic interference. The aim of this study was to investigate these effects on displayed and actual ventilator performance. Five ventilators were tested: Drager Oxylog 2000, BREAS LTV-1000, Respironics BiPAP VISION, Puritan Bennett 7200 and 840. Electromagnetic interference was generated by three devices: Simoco 8020 radio handset, Nokia 7210 and Nokia 6230 mobile phone, Nokia 6230 communicating via Bluetooth with a Palm Tungsten T Personal Digital Assistant. We followed the American National Standard Recommended Practice for On-Site, Ad Hoc Testing (ANSI C63) for electromagnetic interference. We used a ventilator tester, to simulate healthy adult lungs and measure ventilator performance. The communication device under test was moved in towards each ventilator from a distance of 1 m in six axes. Alarms or error codes on the ventilator were recorded, as was ventilator performance. All ventilators tested, except for the Respironics VISION, showed a display error when subjected to electromagnetic interference from the Nokia phones and Simoco radio. Ventilator performance was only affected by the radio which caused the Puritan Bennett 840 to stop functioning completely. The transfer ventilators' performance were not affected by radio or mobile phone, although the mobile phone did trigger a low-power alarm. Effects on intensive care ventilators included display reset, with the ventilator restoring normal display function within 2 s, and low-power/low-pressure alarms. Bluetooth transmission had no effect on the function of all the ventilators tested. In a clinical setting, high-power-output devices such as a two-way radio may cause significant interference in ventilator function. Medium-power-output devices such as mobile phones may cause minor alarm triggers. Low-power-output devices such as Bluetooth appear to cause no interference with ventilator function.
Data upload capability of 3G mobile phones.
Moon, Jon K; Barden, Charles M; Wohlers, Erica M
2009-01-01
Mobile phones are becoming an important platform to measure free-living energy balance and to support weight management therapies. Sensor data, camera images and user input are needed by clinicians and researchers in close to real time. We assessed upload (reverse link) data transport rates for 2007-2008 model mobile phones on two major US wireless systems. Even the slowest phone (EVDO Rev 0) reliably uploaded 40 MB of data in less than 1 h. More than 95% of file uploads were successful in tests that simulated normal phone use over 3 d. Practical bandwidth and data currency from typical smart phones will likely keep pace with the data needs of energy balance studies and weight management therapy.
Mobile phones, cordless phones and the risk for brain tumours.
Hardell, Lennart; Carlberg, Michael
2009-07-01
The Hardell-group conducted during 1997-2003 two case control studies on brain tumours including assessment of use of mobile phones and cordless phones. The questionnaire was answered by 905 (90%) cases with malignant brain tumours, 1,254 (88%) cases with benign tumours and 2,162 (89%) population-based controls. Cases were reported from the Swedish Cancer Registries. Anatomical area in the brain for the tumour was assessed and related to side of the head used for both types of wireless phones. In the current analysis we defined ipsilateral use (same side as the tumour) as >or=50% of the use and contralateral use (opposite side) as <50% of the calling time. We report now further results for use of mobile and cordless phones. Regarding astrocytoma we found highest risk for ipsilateral mobile phone use in the >10 year latency group, OR=3.3, 95% CI=2.0-5.4 and for cordless phone use OR=5.0, 95% CI=2.3-11. In total, the risk was highest for cases with first use <20 years age, for mobile phone OR=5.2, 95% CI=2.2-12 and for cordless phone OR=4.4, 95% CI=1.9-10. For acoustic neuroma, the highest OR was found for ipsilateral use and >10 year latency, for mobile phone OR=3.0, 95% CI=1.4-6.2 and cordless phone OR=2.3, 95% CI=0.6-8.8. Overall highest OR for mobile phone use was found in subjects with first use at age <20 years, OR=5.0, 95% CI 1.5-16 whereas no association was found for cordless phone in that group, but based on only one exposed case. The annual age-adjusted incidence of astrocytoma for the age group >19 years increased significantly by +2.16%, 95% CI +0.25 to +4.10 during 2000-2007 in Sweden in spite of seemingly underreporting of cases to the Swedish Cancer Registry. A decreasing incidence was found for acoustic neuroma during the same period. However, the medical diagnosis and treatment of this tumour type has changed during recent years and underreporting from a single center would have a large impact for such a rare tumour.
Hardell, Lennart; Carlberg, Michael; Söderqvist, Fredrik; Mild, Kjell Hansson
2013-12-01
Previous studies have shown a consistent association between long-term use of mobile and cordless phones and glioma and acoustic neuroma, but not for meningioma. When used these phones emit radiofrequency electromagnetic fields (RF-EMFs) and the brain is the main target organ for the handheld phone. The International Agency for Research on Cancer (IARC) classified in May, 2011 RF-EMF as a group 2B, i.e. a 'possible' human carcinogen. The aim of this study was to further explore the relationship between especially long-term (>10 years) use of wireless phones and the development of malignant brain tumours. We conducted a new case-control study of brain tumour cases of both genders aged 18-75 years and diagnosed during 2007-2009. One population-based control matched on gender and age (within 5 years) was used to each case. Here, we report on malignant cases including all available controls. Exposures on e.g. use of mobile phones and cordless phones were assessed by a self-administered questionnaire. Unconditional logistic regression analysis was performed, adjusting for age, gender, year of diagnosis and socio-economic index using the whole control sample. Of the cases with a malignant brain tumour, 87% (n=593) participated, and 85% (n=1,368) of controls in the whole study answered the questionnaire. The odds ratio (OR) for mobile phone use of the analogue type was 1.8, 95% confidence interval (CI)=1.04‑3.3, increasing with >25 years of latency (time since first exposure) to an OR=3.3, 95% CI=1.6-6.9. Digital 2G mobile phone use rendered an OR=1.6, 95% CI=0.996-2.7, increasing with latency >15-20 years to an OR=2.1, 95% CI=1.2-3.6. The results for cordless phone use were OR=1.7, 95% CI=1.1-2.9, and, for latency of 15-20 years, the OR=2.1, 95% CI=1.2-3.8. Few participants had used a cordless phone for >20-25 years. Digital type of wireless phones (2G and 3G mobile phones, cordless phones) gave increased risk with latency >1-5 years, then a lower risk in the following latency groups, but again increasing risk with latency >15-20 years. Ipsilateral use resulted in a higher risk than contralateral mobile and cordless phone use. Higher ORs were calculated for tumours in the temporal and overlapping lobes. Using the meningioma cases in the same study as reference entity gave somewhat higher ORs indicating that the results were unlikely to be explained by recall or observational bias. This study confirmed previous results of an association between mobile and cordless phone use and malignant brain tumours. These findings provide support for the hypothesis that RF-EMFs play a role both in the initiation and promotion stages of carcinogenesis.
Wosar, Marc A; Marcellin-Little, Denis J; Roe, Simon C
2002-01-01
To evaluate the effects of bolt torque, wire size, and component reuse on the ability to maintain wire tension in 3 external skeletal fixation systems. Biomechanical study. Yield strength in tension of 1.0-, 1.2-, 1.5-, and 1.6-mm-diameter wires, and yield strength in torque of Hofmann Small Bone Fixation (SBF) cannulated and slotted bolts and IMEX regular and miniature bolts were determined on a testing machine. The minimum bolt tightening torque needed to prevent wire slippage at clinically recommended wire tensions was determined. Components were tested 10 times, and loads at slippage were recorded. The IMEX system required a mean of 8 Nm of bolt tightening torque to maintain 900 N (1.6-mm wires). The SBF system required a mean of 3 Nm bolt torque to maintain 300 N (1.0-mm wires) and 5 Nm to maintain 600 N (1.2-mm wires). The SBF cannulated bolt required 9 Nm of torque to maintain 900 N (1.5-mm wires). The SBF slotted bolts could only maintain 800 N before yield. The IMEX miniature system required a mean bolt torque of 1.1 Nm to maintain 300 N. The cannulated and slotted bolts from both manufacturers failed to maintain 70% of initial wire tension after 7 and 4 uses, respectively. The IMEX systems and the SBF system using 1.0- and 1.2-mm wires could maintain clinically recommended wire tension safely. Only the IMEX system could maintain clinically recommended wire tension safely using 1.5- or 1.6-mm wires. The SBF system using 1.0- and 1.2-mm wires and the IMEX system using all wire sizes can maintain clinically relevant wire tension. The SBF system using 1.5-mm wires could not. Cannulated and slotted bolts should not be used more than 6 and 3 times, respectively. Nuts should not be reused. Copyright 2002 by The American College of Veterinary Surgeons
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guo, Rui; Gao, Liming, E-mail: liming.gao@sjtu.edu.cn; Li, Ming, E-mail: mingli90@sjtu.edu.cn
As the continuous shrinkage of the interconnect line width in microelectronics devices, there is a growing concern about the electromigration (EM) failure of bonding wire. In addition, an innovative Ag–8Au–3Pd alloy wire has shown promise as an economical substitute for gold wire interconnects due to the cost pressure of gold in the last decade. In present study of the Ag–8Au–3Pd alloy wire, the surface diffusion occupied the dominant position during EM failure, and the activation energy was found to be 0.61 eV. In order to reveal the failure mechanism, the cross-sections of the Ag–8Au–3Pd alloy wire during EM were preparedmore » by focused ion beam (FIB) micro-machining for electron backscatter diffraction (EBSD) analysis. The microstructure evolution of the Ag–8Au–3Pd alloy wire was characterized by the grain size and grain boundary. As a result, the EM failure originates in the atom transportation, which causes grain size increasing and atom diffusion on the wire surface. - Highlights: • The activation energy of Ag–8Au–3Pd alloy wire was obtained as 0.61 eV. • During EM, the silver atoms diffused from negative to the positive terminal on the wire surface. • The microstructure (grain size and grain boundary) was characterized by FIB-EBSD. • During EM, the atom transportation was found to cause grain size growth and atom diffusion on the wire surface.« less
Evaluation of Interference of Cellular Phones on Electronic Apex Locators: An In Vitro Study.
Sidhu, Preena; Shankargouda, Swapnil; Dicksit, Daniel DevaPrakash; Mahdey, Haydar Majeed; Muzaffar, Danish; Arora, Shelly
2016-04-01
Use of mobile phone has been prohibited in many hospitals to prevent interference with medical devices. Electromagnetic radiation emitted from cellular phones might interfere with electronic working length determination. The purpose of this in vitro study was to evaluate the effect of a smart phone (Samsung Galaxy Note Edge) on working length determination of electronic apex locators (EALs) Propex II and Rootor. Fifteen intact, non-carious single-rooted teeth were decoronated at the cementoenamel junction. Visually, working length was determined by using a #15 K-file under stereomicroscope (×20). The effect of cellular phones on electronic working length (EWL) was determined under 2 experimental settings: (1) in a closed room with poor signal strength and (2) in a polyclinic set up with good signal strength and 5 conditions: (1) electronically, without cellular phone in room; (2) electronically, with cellular phone in physical contact with EAL; (3) electronically, with mobile phone in physical contact with EAL and in calling mode for a period of 25 seconds; (4) electronically, mobile phone placed at a distance of 40 cm from the EAL; and (5) electronically, mobile phone placed at a distance of 40 cm and in calling mode for a period of 25 seconds. The EWL was measured 3 times per tooth under each condition. Stability of the readings was scored from 1 to 3: (1) good stability, (2) stable reading after 1 attempt, and (3) stable reading after 2 attempts. The data were compared by using analysis of variance. The EWL measurements were not influenced by the presence of cellular phone and could be determined under all experimental conditions. Within the limitations of this study, it can be concluded that mobile phones do not interfere with the EWL determination. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Improving Family Communication.
Medrano, Vilma; Bonilla, Gladys; Hernández, Ericka; Romanjek, Mariana Harnecker; Gómez, Adriana; Hernández, Jasón; Reyes, Marcela Ríos; Lindenberg, Cathy Strachan
2017-03-01
TeenSmart International harnesses the power and flexibility of technology to empower youth to take personal responsibility for their health and lifestyle choices. Access to the Internet via mobile phones is often cheaper than paying to connect to a wired broadband service, and in rural areas, mobile networks may be the only means of accessing the Internet. This study assessed the feasibility, acceptability, and impact of "cues to action" or brief motivating cell phone text messages to improve adolescent family communication and relationships. A quasi-experimental design using a voluntary sample of 100 Nicaraguan youth at high risk for poor family communication participated. Pre- and posttest quantitative measures using Student t statistical analysis, a focus group, and a participant testimony provided the evaluation evidence. Findings suggest that there are economic and motivational barriers to the use of text messages, but when barriers are eliminated, the behavioral results are positive. Youth who received two weekly text messages over a 6-month period demonstrated statistically significant improvements in family communication perceptions, attitudes, and behaviors, strengthening their family communications and relationships. Brief and personalized text messaging "cues to action" may be a cost-effective intervention to improve adolescent healthy lifestyle behaviors.
Greening academia: Use and disposal of mobile phones among university students
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ongondo, F.O.; Williams, I.D., E-mail: idw@soton.ac.uk
Research highlights: > Students use/disposal of mobile phones was assessed via a large-scale survey and a takeback trial. > We estimate 3.7 m phones stockpiled by UK students; 29.3 and 28.1 m stockpiled for Europe and USA. > Many students replace phones at least once a year; only a small number have used a takeback service. > Monetary incentives have greatest influence over willingness to utilise takeback services. > Universities should partner with established operators to conduct targeted takeback services. - Abstract: Mobile phones have relatively short lifecycles and are rapidly seen as obsolete by many users within little overmore » a year. However, the reusability of these devices as well as their material composition means that in terms of mass and volume, mobile phones represent the most valuable electronic products that are currently found in large numbers in waste streams. End-of-life mobile phones are a high value (from a reuse and resource perspective), high volume (quantity), low cost (residual monetary value) and transient (short lifecycle) electronic product. There are very large numbers of higher education (mainly university) students in the world - there are >2.4 million in the UK alone, 19 million in Europe and 18.2 million in the USA - and they often replace their mobile phones several times before graduation. Thus, because of the potentially significant environmental and economic impacts, a large scale survey of students at 5 UK universities was conducted to assess the behaviour of students with regard to their use and disposal of mobile phones. Additionally, a small scale trial mobile phone takeback service at one of the universities was carried out. The findings indicate that many students replace their phones at least once a year; replacing broken phones, getting upgrades from network operators, remaining 'fashionable' and a desire to have a handset with a longer battery life are the main reasons for such rapid replacement. Almost 60% of replaced phones are not sent to reuse or recycling operations but are stockpiled by students mainly as spare/backup phones. Approximately 61% of students own an extra mobile phone with male students replacing their phones more often than females. In particular, the results highlight the potentially huge stockpile of mobile phones - and consequently valuable supplies of rare metals - being held by the public; we estimate that there are 3.7 million phones stockpiled by students in UK higher education alone (29.3 and 28.1 million stockpiled, respectively, for Europe and USA). Although many students are aware of UK mobile phone takeback services, only a moderate number have previously used the services. Students' recycling of other waste materials such as paper and glass did not have a significant impact on their disposal actions for their unwanted mobile phones, although students who often recycled these waste materials were also the most willing to participate in mobile phone takeback services. Monetary incentives such as cash payments and vouchers have the greatest influence over students' willingness to utilise takeback services, followed by convenience and ease of use of the services. The paper discusses these findings as well as the outcome of the trial mobile phone takeback. It is suggested that universities should partner with established takeback operators to conduct event-based mobile phone takeback services primarily targeting students. Lessons from mobile phone takeback applicable to takeback services for end-of-life gadgets similar to mobile phones are also discussed.« less
Tomé, Angelo R; Castro, Enrique; Santos, Rosa M; Rosário, Luís M
2007-06-20
2-Methylthioadenosine 5'-triphosphate (2-MeSATP), formerly regarded as a specific P2Y (metabotropic) purinergic receptor agonist, stimulates Ca2+ influx and evokes catecholamine release from adrenal chromaffin cells. These cells express P2Y and P2X (ionotropic) purinoceptors, with the latter providing an important Ca2+ influx pathway. Using single cell calcium imaging techniques, we have determined whether 2-MeSATP might be a specific P2X receptor agonist in bovine chromaffin cells and assessed the relative role of P2X and P2Y receptors on catecholamine secretion from these cells. ATP raised the [Ca2+]i in ~50% of the cells. Removing extracellular Ca2+ suppressed the [Ca2+]i-raising ability of 2-MeSATP, observed in ~40% of the ATP-sensitive cells. This indicates that 2-MeSATP behaves as a specific ionotropic purinoceptor agonist in bovine chromaffin cells. The 2-MeSATP-induced [Ca2+]i-rises were suppressed by PPADS. UTP raised the [Ca2+]i in ~40% of the ATP-sensitive cells, indicating that these expressed Ca2+-mobilizing P2Y receptors. UTP-sensitive receptors may not be the only P2Y receptors present, as suggested by the observation that ~20% of the ATP-sensitive pool did not respond to either 2-MeSATP or UTP. The average sizes of the ATP- and 2-MeSATP-evoked [Ca2+]i responses were identical in UTP-insensitive cells. 2-MeSATP stimulated Ca2+ influx and evoked catecholamine release, whereas UTP elicited Ca2+ release from intracellular stores but did not evoke secretion. 2-MeSATP-induced secretion was strongly inhibited by Cd2+ and suppressed by extracellular Ca2+ or Na+ removal. TTX inhibited 2-MeSATP-evoked secretion by ~20%. 2-MeSATP is a specific P2X purinoceptor agonist and a potent secretagogue in bovine chromaffin cells. Activation of 2-MeSATP-sensitive receptors stimulates Ca2+ influx mainly via voltage-sensitive Ca2+ channels. For the most part, these are activated by the depolarization brought about by Na+ influx across P2X receptor pores.
Tamura, Haruka; Nishida, Tomoko; Tsuji, Akiyo; Sakakibara, Hisataka
2017-06-29
The aim of this study was to investigate the relationship between mobile phone use and insomnia and depression in adolescents. A cross-sectional study was conducted on 295 high school students aged 15-19 in Japan. Insomnia and depression were assessed using Athene Insomnia Scales (AIS) and the Center for Epidemiologic Studies Depression Scale (CES-D), respectively. Mobile phones were owned by 98.6% of students; 58.6% used mobile phones for over 2 h per day and 10.5% used them for over 5 h per day. Overall mobile phone use of over 5 h per day was associated with shorter sleep duration and insomnia (OR: 3.89 [[95% CI: 1.21-12.49]), but not with depression. Mobile phone use of 2 h or more per day for social network services (OR: 3.63 [[1.20-10.98]) and online chats (OR: 3.14 [[1.42-6.95]), respectively, was associated with a higher risk of depression. Mobile phone overuse can be linked to unhealthy sleep habits and insomnia. Moreover, mobile phone overuse for social network services and online chats may contribute more to depression than the use for internet searching, playing games or viewing videos.
NASA Technical Reports Server (NTRS)
Lundquist, Ray A.; Leidecker, Henning
1999-01-01
The allowable operating currents of electrical wiring when used in the space vacuum environment is predominantly determined by the maximum operating temperature of the wire insulation. For Kapton insulated wire this value is 200 degree C. Guidelines provided in the Goddard Space Flight Center (GSFC) Preferred Parts List (PPL) limit the operating current of wire within vacuum to ensure the maximum insulation temperature is not exceeded. For 20 AWG wire, these operating parameters are: (1) 3.7 amps per wire (2) bundle of 15 or more wires (3) 70 C environment (4) vacuum of 10(exp -5) torr or less To determine the behavior and temperature of electrical wire at different operating conditions, a thermal vacuum test was performed on a representative electrical harness of the Hubble Space Telescope (HST) power distribution system. This paper describes the test and the results.
NASA Technical Reports Server (NTRS)
Lundquist, Ray A.; Leidecker, Henning
1998-01-01
The allowable operating currents of electrical wiring when used in the space vacuum environment is predominantly determined by the maximum operating temperature of the wire insulation. For Kapton insulated wire this value is 200 C. Guidelines provided in the Goddard Space Flight Center (GSFC) Preferred Parts List (PPL) limit the operating current of wire within vacuum to ensure the maximum insulation temperature is not exceeded. For 20 AWG wire, these operating parameters are: (1) 3.7 amps per wire; (2) bundle of 15 or more wires; (3) 70 C environment: and (4) vacuum of 10(exp -5) torr or less. To determine the behavior and temperature of electrical wire at different operating conditions, a thermal vacuum test was performed on a representative electrical harness of the Hubble Space Telescope (HST) power distribution system. This paper describes the test and the results.
HARDELL, LENNART; CARLBERG, MICHAEL; SÖDERQVIST, FREDRIK; MILD, KJELL HANSSON
2013-01-01
Previous studies have shown a consistent association between long-term use of mobile and cordless phones and glioma and acoustic neuroma, but not for meningioma. When used these phones emit radiofrequency electromagnetic fields (RF-EMFs) and the brain is the main target organ for the hand-held phone. The International Agency for Research on Cancer (IARC) classified in May, 2011 RF-EMF as a group 2B, i.e. a ‘possible’ human carcinogen. The aim of this study was to further explore the relationship between especially long-term (>10 years) use of wireless phones and the development of malignant brain tumours. We conducted a new case-control study of brain tumour cases of both genders aged 18–75 years and diagnosed during 2007–2009. One population-based control matched on gender and age (within 5 years) was used to each case. Here, we report on malignant cases including all available controls. Exposures on e.g. use of mobile phones and cordless phones were assessed by a self-administered questionnaire. Unconditional logistic regression analysis was performed, adjusting for age, gender, year of diagnosis and socio-economic index using the whole control sample. Of the cases with a malignant brain tumour, 87% (n=593) participated, and 85% (n=1,368) of controls in the whole study answered the questionnaire. The odds ratio (OR) for mobile phone use of the analogue type was 1.8, 95% confidence interval (CI)=1.04–3.3, increasing with >25 years of latency (time since first exposure) to an OR=3.3, 95% CI=1.6–6.9. Digital 2G mobile phone use rendered an OR=1.6, 95% CI=0.996–2.7, increasing with latency >15–20 years to an OR=2.1, 95% CI=1.2–3.6. The results for cordless phone use were OR=1.7, 95% CI=1.1–2.9, and, for latency of 15–20 years, the OR=2.1, 95% CI=1.2–3.8. Few participants had used a cordless phone for >20–25 years. Digital type of wireless phones (2G and 3G mobile phones, cordless phones) gave increased risk with latency >1–5 years, then a lower risk in the following latency groups, but again increasing risk with latency >15–20 years. Ipsilateral use resulted in a higher risk than contralateral mobile and cordless phone use. Higher ORs were calculated for tumours in the temporal and overlapping lobes. Using the meningioma cases in the same study as reference entity gave somewhat higher ORs indicating that the results were unlikely to be explained by recall or observational bias. This study confirmed previous results of an association between mobile and cordless phone use and malignant brain tumours. These findings provide support for the hypothesis that RF-EMFs play a role both in the initiation and promotion stages of carcinogenesis. PMID:24064953
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-07
... respect of real-time data with monthly access fees. Pursuant to Rule 608(b)(3)(i) under the Act, the... that the Participants impose in respect of real- time data with monthly access fees. The proposed... propose to establish the monthly fee for access to UTP Level 1 real-time data feeds at $1,500 for direct...
2010 Survey on cell phone use while performing cardiopulmonary bypass.
Smith, T; Darling, E; Searles, B
2011-09-01
Cell phone use in the U.S. has increased dramatically over the past decade and text messaging among adults is now mainstream. In professions such as perfusion, where clinical vigilance is essential to patient care, the potential distraction of cell phones may be especially problematic. However, the extent of this as an issue is currently unknown. Therefore, the purpose of this study was to (1) determine the frequency of cell phone use in the perfusion community, and (2) to identify concerns and opinions among perfusionists regarding cell phone use. In October 2010, a link to a 19-question survey (surveymonkey.com) was posted on the AmSECT (PerfList) and Perfusion.com (PerfMail) forums. There were 439 respondents. Demographic distribution is as follows; Chief Perfusionist (30.5%), Staff Perfusionist (62.0%), and Other (7.5%), with age ranges of 20-30 years (14.2%), 30-40 years (26.5%), 40-50 years (26.7%), 50-60 years (26.7%), >60 years (5.9%). The use of a cell phone during the performance of cardiopulmonary bypass (CPB) was reported by 55.6% of perfusionists. Sending text messages while performing CPB was acknowledged by 49.2%, with clear generational differences detected when cross-referenced with age groups. For smart phone features, perfusionists report having accessed e-mail (21%), used the internet (15.1%), or have checked/posted on social networking sites (3.1%) while performing CPB. Safety concerns were expressed by 78.3% who believe that cell phones can introduce a potentially significant safety risk to patients. Speaking on a cell phone and text messaging during CPB are regarded as "always an unsafe practice" by 42.3% and 51.7% of respondents, respectively. Personal distraction by cell phone use that negatively affected performance was admitted by 7.3%, whereas witnessing another perfusionist distracted with phone/text while on CPB was acknowledged by 33.7% of respondents. This survey suggests that the majority of perfusionists believe cell phones raise significant safety issues while operating the heart-lung machine. However, the majority also have used a cell phone while performing this activity. There are clear generational differences in opinions on the role and/or appropriateness of cell phones during bypass. There is a need to further study this issue and, perhaps, to establish consensus on the use of various communication modes within the perfusion community.
50 CFR 654.22 - Gear restrictions.
Code of Federal Regulations, 2010 CFR
2010-10-01
... corrodible loop composed of non-coated steel wire measuring 24 gauge or thinner, or an untreated pine dowel... thicker than 3/8 inch (0.95 cm); (3) Non-coated steel wire measuring 24 gauge or thinner; (4) A panel of..., untreated pine slat(s), non-coated steel wire, wire mesh panel, or corner fasteners degrade, the opening in...
50 CFR 654.22 - Gear restrictions.
Code of Federal Regulations, 2011 CFR
2011-10-01
... corrodible loop composed of non-coated steel wire measuring 24 gauge or thinner, or an untreated pine dowel... thicker than 3/8 inch (0.95 cm); (3) Non-coated steel wire measuring 24 gauge or thinner; (4) A panel of..., untreated pine slat(s), non-coated steel wire, wire mesh panel, or corner fasteners degrade, the opening in...
33 CFR 165.803 - Mississippi River-regulated navigation area.
Code of Federal Regulations, 2013 CFR
2013-07-01
... breaking strength of three parts of 7/8 inch diameter wire rope; or (3) Fixed rigging that is at least... end of the tier is secured to at least one mooring device. (3) Each wire rope used between the... inch diameter wire rope. (4) Each wire rope used between the downstream end of a barge and a mooring...
33 CFR 165.803 - Mississippi River-regulated navigation area.
Code of Federal Regulations, 2012 CFR
2012-07-01
... breaking strength of three parts of 7/8 inch diameter wire rope; or (3) Fixed rigging that is at least... end of the tier is secured to at least one mooring device. (3) Each wire rope used between the... inch diameter wire rope. (4) Each wire rope used between the downstream end of a barge and a mooring...
33 CFR 165.803 - Mississippi River-regulated navigation area.
Code of Federal Regulations, 2011 CFR
2011-07-01
... breaking strength of three parts of 7/8 inch diameter wire rope; or (3) Fixed rigging that is at least... end of the tier is secured to at least one mooring device. (3) Each wire rope used between the... inch diameter wire rope. (4) Each wire rope used between the downstream end of a barge and a mooring...
33 CFR 165.803 - Mississippi River-regulated navigation area.
Code of Federal Regulations, 2014 CFR
2014-07-01
... breaking strength of three parts of 7/8 inch diameter wire rope; or (3) Fixed rigging that is at least... end of the tier is secured to at least one mooring device. (3) Each wire rope used between the... inch diameter wire rope. (4) Each wire rope used between the downstream end of a barge and a mooring...
Oh, You Na; Ha, Keong Jun; Kim, Joon Bum; Jung, Sung-Ho; Choo, Suk Jung; Chung, Cheol Hyun; Lee, Jae Won
2015-08-01
Stainless steel wiring remains the most popular technique for primary sternal closure. Recently, a multifilament cable wiring system (Pioneer Surgical Technology Inc., Marquette, MI, USA) was introduced for sternal closure and has gained wide acceptance due to its superior resistance to tension. We aimed to compare conventional steel wiring to multifilament cable fixation for sternal closure in patients undergoing major cardiac surgery. Data were collected retrospectively on 1,354 patients who underwent sternal closure after major cardiac surgery, using either the multifilament cable wiring system or conventional steel wires between January 2009 and October 2010. The surgical outcomes of these two groups of patients were compared using propensity score matching based on 18 baseline patient characteristics. Propensity score matching yielded 392 pairs of patients in the two groups whose baseline profiles showed no significant differences. No significant differences between the two groups were observed in the rates of early mortality (2.0% vs. 1.3%, p=0.578), major wound complications requiring reconstruction (1.3% vs. 1.3%, p>0.99), minor wound complications (3.6% vs. 2.0%, p=0.279), or mediastinitis (0.8% vs. 1.0%, p=1.00). Patients in the multifilament cable group had fewer sternal bleeding events than those in the conventional wire group, but this tendency was not statistically significant (4.3% vs. 7.4%, p=0.068). The surgical outcomes of sternal closure using multifilament cable wires were comparable to those observed when conventional steel wires were used. Therefore, the multifilament cable wiring system may be considered a viable option for sternal closure in patients undergoing major cardiac surgery.
Look who's talking! A roadside survey of drivers' cell phone use.
Young, Kristie L; Rudin-Brown, Christina M; Lenné, Michael G
2010-12-01
The objective of this study was to quantify Melbourne drivers' rates of handheld and hands-free phone use and the driver, vehicle, site, and time characteristics associated with phone use. Additionally, this study sought to examine any change in the prevalence of handheld cell phone use by Melbourne drivers between 2006 and 2009. Observational survey of vehicle drivers at various times of the day and week at 3 sites across metropolitan Melbourne during May 2009. A total of 195 (3.4%) of the 5813 drivers observed were using handheld phones and 81 (1.4%) were using hands-free phones. This represents a significant increase in handheld phone usage rates compared to those found in an earlier study conducted in Melbourne in 2006. Cell phone use was associated with a range of driver, vehicle, site, and time characteristics. Handheld phone users were predominately young or middle-aged drivers who drove cars or 4-wheel-drive vehicles (4WDs), and this activity was more likely to occur in the late afternoon. Use of hands-free phones did not differ significantly across gender, age group, vehicle type, observation site, or time of day; however, use of hands-free phones was higher on weekdays compared to weekends. Despite legislation being in place, drivers' handheld cell phone use is still a major road safety concern, particularly for young and middle-aged drivers. The effectiveness of other strategies for decreasing handheld usage rates, including increased surveillance and tougher penalties, need to be ascertained.
Understanding Irreversible Degradation of Nb3Sn Wires with Fundamental Fracture Mechanics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhai, Yuhu; Calzolaio, Ciro; Senatore, Carmine
2014-08-01
Irreversible performance degradation of advanced Nb3Sn superconducting wires subjected to transverse or axial mechanical loading is a critical issue for the design of large-scale fusion and accelerator magnets such as ITER and LHC. Recent SULTAN tests indicate that most cable-in-conduit conductors for ITER coils made of Nb3Sn wires processed by various fabrication techniques show similar performance degradation under cyclic loading. The irreversible degradation due to filament fracture and local strain accumulation in Nb3Sn wires cannot be described by the existing strand scaling law. Fracture mechanic modeling combined with X-ray diffraction imaging of filament micro-crack formation inside the wires under mechanicalmore » loading may reveal exciting insights to the wire degradation mechanisms. We apply fundamental fracture mechanics with a singularity approach to study influence of wire filament microstructure of initial void size and distribution to local stress concentration and potential crack propagation. We report impact of the scale and density of the void structure on stress concentration in the composite wire materials for crack initiation. These initial defects result in an irreversible degradation of the critical current beyond certain applied stress. We also discuss options to minimize stress concentration in the design of the material microstructure for enhanced wire performance for future applications.« less
Serum protein removal from skim milk with a 3-stage, 3× ceramic Isoflux membrane process at 50°C.
Adams, Michael C; Barbano, David M
2013-04-01
Small pore microfiltration (MF) can be used to remove serum proteins (SP) from skim milk. The process's SP removal efficiency directly influences the technology's economic feasibility. Our objective was to quantify the capacity of 0.14μm ceramic Isoflux MF membranes (TAMI, Nyons, France) to remove SP from skim milk. A 3-stage, 3×, feed-and-bleed MF study with diafiltration in the latter 2 stages was conducted at 50°C using Isoflux membranes to determine cumulative SP removal percentages and SP removal rates at each processing stage. The experiment was replicated 3 times starting with 3 separate lots of raw milk. In contrast to 3× MF theoretical cumulative SP removal percentages of 68, 90, and 97% after 1, 2, and 3 stages, respectively, the 3× Isoflux MF process removed only 39.5, 58.4, and 70.2% of SP after 1, 2, and 3 stages, respectively. Previous research has been published that provides the skim milk SP removal capacities of 3-stage, 3× 0.1μm ceramic Membralox (Pall Corp., Cortland, NY) uniform transmembrane pressure (UTP), 0.1μm ceramic Membralox graded permeability (GP), and 0.3μm polymeric polyvinylidene fluoride spiral-wound (PVDF-SW) MF systems (Parker-Hannifin, Process Advanced Filtration Division, Tell City, IN) at 50°C. No difference in cumulative SP removal percentage after 3 stages was detected between the Isoflux and previously published PVDF-SW values (70.3%), but SP removal was lower than published GP (96.5%) and UTP (98.3%) values. To remove 95% of SP from 1,000kg of skim milk in 12h it would take 7, 3, 3, and 7 stages with 6.86, 1.91, 2.82, and 17.98m(2) of membrane surface area for the Isoflux, GP, UTP, and PVDF-SW systems, respectively. The MF systems requiring more stages would produce additional permeate at lower protein concentrations. The ceramic MF systems requiring more surface area would incur higher capital costs. The authors hypothesize that SP removal with the Isoflux membranes was lower than theoretical for the following reasons: a range of membrane pore sizes existed (i.e., some pores were too small to pass SP), the selective layer modification and reverse flow conditions at the membrane outlet combined to reduce the effective membrane surface area, and the geometric shape of the Isoflux flow channels promoted early fouling of the membrane and rejection of SP by the foulant. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Nishida, Tomoko; Tsuji, Akiyo; Sakakibara, Hisataka
2017-01-01
The aim of this study was to investigate the relationship between mobile phone use and insomnia and depression in adolescents. A cross-sectional study was conducted on 295 high school students aged 15–19 in Japan. Insomnia and depression were assessed using Athene Insomnia Scales (AIS) and the Center for Epidemiologic Studies Depression Scale (CES-D), respectively. Mobile phones were owned by 98.6% of students; 58.6% used mobile phones for over 2 h per day and 10.5% used them for over 5 h per day. Overall mobile phone use of over 5 h per day was associated with shorter sleep duration and insomnia (OR: 3.89 [95% CI: 1.21–12.49]), but not with depression. Mobile phone use of 2 h or more per day for social network services (OR: 3.63 [1.20–10.98]) and online chats (OR: 3.14 [1.42–6.95]), respectively, was associated with a higher risk of depression. Mobile phone overuse can be linked to unhealthy sleep habits and insomnia. Moreover, mobile phone overuse for social network services and online chats may contribute more to depression than the use for internet searching, playing games or viewing videos. PMID:28661428
Surface topography, hardness, and frictional properties of GFRP for esthetic orthodontic wires.
Inami, Toshihiro; Tanimoto, Yasuhiro; Yamaguchi, Masaru; Shibata, Yo; Nishiyama, Norihiro; Kasai, Kazutaka
2016-01-01
In our previous study, glass-fiber-reinforced plastics (GFRPs) made from polycarbonate and glass fiber for esthetic orthodontic wires were prepared by using pultrusion. The purpose of the present study was to investigate the surface topography, hardness, and frictional properties of GFRPs. To investigate how fiber diameter affects surface properties, GFRP round wires with a diameter of 0.45 mm (0.018 in.) were prepared incorporating either 13 μm (GFRP-13) or 7 μm (GFRP-7) glass fibers. As controls, stainless steel (SS), cobalt-chromium-nickel alloy, β-titanium (β-Ti) alloy, and nickel-titanium (Ni-Ti) alloy were also evaluated. Under scanning electron microscopy and scanning probe microscopy, the β-Ti samples exhibited greater surface roughness than the other metallic wires and the GFRP wires. The dynamic hardness and elastic modulus of GFRP wires obtained by the dynamic micro-indentation method were much lower than those of metallic wires (p < 0.05). Frictional forces against the polymeric composite brackets of GFRP-13 and GFRP-7 were 3.45 ± 0.49 and 3.60 ± 0.38 N, respectively; frictional forces against the ceramic brackets of GFRP-13 and GFRP-7 were 3.39 ± 0.58 and 3.87 ± 0.48 N, respectively. For both bracket types, frictional forces of GFRP wires and Ni-Ti wire were nearly half as low as those of SS, Co-Cr, and β-Ti wires. In conclusion, there was no significant difference in surface properties between GFRP-13 and GFRP-7; presumably because both share the same polycarbonate matrix. We expect that GFRP wires will deliver superior sliding mechanics with low frictional resistance between the wire and bracket during orthodontic treatment. © 2015 Wiley Periodicals, Inc.
Finite-element analysis of transverse compressive and thermal loads on Nb 3Sn wires with voids
Zhai, Y.; D'Hauthuille, L.; Barth, C.; ...
2016-02-29
High-field superconducting magnets play a very important role in many large-scale physics experiments, particularly particle colliders and fusion confinement devices such as Large Hadron Collider (LHC) and International Thermonuclear Experimental Reactor (ITER). The two most common superconductors used in these applications are NbTi and Nb 3Sn. Nb 3Sn wires are favored because of their significantly higher J c (critical current density) for higher field applications. The main disadvantage of Nb 3Sn is that the superconducting performance of the wire is highly strain sensitive and it is very brittle. This strain sensitivity is strongly influenced by two factors: plasticity and crackedmore » filaments. Cracks are induced by large stress concentrators that can be traced to the presence of voids in the wire. We develop detailed 2-D and 3-D finite-element models containing wire filaments and different possible distributions of voids in a bronze-route Nb 3Sn wire. We apply compressive transverse loads for various cases of void distributions to simulate the stress and strain response of a Nb 3Sn wire under the Lorentz force. Furthermore, this paper improves our understanding of the effect voids have on the Nb 3Sn wire's mechanical properties, and in so, the connection between the distribution of voids and performance degradation such as the correlation between irreversible strain limit and the void-induced local stress concentrations.« less
Strain tolerance in technical Nb3Al superconductors
NASA Astrophysics Data System (ADS)
Banno, N.; Takeuchi, T.; Kitaguchi, H.; Tagawa, K.
2006-10-01
We observed crack formation in transformation-processed Nb3Al wires at room temperature, the wire being bent with a small clamp fixture with a curvature. The polished cross-section parallel to the longitudinal axis was observed, using a high power optical microscope or a field-emission scanning electron microscope. The bend strain limit for microcrack formation is found, changing the radius of the curvature of the clamp. The bend strain limit was found to be around 0.3% for standard Nb3Al wires. This corresponds to the irreversible tensile strain limit of the Ic characteristics determined with a 0.1 µV cm-1 criterion. Reduction of the barrier thickness should be avoided to keep to the bend strain limit. A new configuration of the Nb3Al wire is demonstrated to improve the bend strain limit. The filament is divided into segments in the transverse cross-section. The wire is fabricated by a double-stacking method. The bend strain limit is enhanced to about 0.85% for the wire surface; the equivalent strain of the outermost filament location is about 0.66%. A simple react and wind test for this wire was performed, where the wire experienced 0.86% bend strain. The degradation of Jc was found to be very small.
77 FR 67735 - Open Meeting of the Taxpayer Advocacy Panel Toll-Free Phone Line Project Committee
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-13
... Toll-Free Phone Line Project Committee AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Notice of Meeting. SUMMARY: An open meeting of the Taxpayer Advocacy Panel Toll-Free Phone Line Project... Taxpayer Advocacy Panel Toll-Free Phone Line Project Committee will be held Monday, December 3rd, 2012...
Hardell, Lennart; Carlberg, Michael; Hansson Mild, Kjell
2006-02-01
The use of cellular and cordless telephones and the risk of brain tumours is of concern since the brain is a high exposure area. We present the results of a pooled analysis of two case-control studies on benign brain tumours diagnosed during 1997-2003 including answers from 1,254 (88%) cases and 2,162 (89%) controls aged 20-80 years. For acoustic neuroma, the use of analogue cellular phones gave an odds ratio (OR) of 2.9 and a 95% confidence interval (CI) of 2.0-4.3; for digital cellular phones, OR=1.5; 95% CI=1.1-2.1; and for cordless telephones, OR=1.5, 95% CI=1.04-2.0. The highest OR was found for analogue phones with a latency period of >15 years; OR=3.8, 95% CI=1.4-10. Regarding meningioma, the results were as follows: for analogue phones, OR=1.3, 95% CI=0.99-1.7; for digital phones, OR=1.1, 95% CI=0.9-1.3; and for cordless phones, OR=1.1, 95% CI=0.9-1.4. In the multivariate analysis, a significantly increased risk of acoustic neuroma was found with the use of analogue phones.
Apoptosis induction in duck tissues during duck hepatitis A virus type 1 infection.
Sheng, X D; Zhang, W P; Zhang, Q R; Gu, C Q; Hu, X Y; Cheng, G F
2014-03-01
To investigate the role of apoptosis in duck viral hepatitis pathogenesis, 4- and 21-d-old ducks were inoculated with duck hepatitis A virus serotype 1 and killed at 2, 6, 12, 24, and 48 h postinfection. TdT-mediated dUTP nick-end labeling was used to detect apoptosis cells. Expression profiles of apoptosis-related genes including caspase-3, -8, -9, and Bcl-2 in spleen, bursa of Fabricius, liver, and the quantity of virus in blood were examined using real-time PCR. The TdT-mediated dUTP nick-end labeling analysis indicated there was a significant difference of apoptotic cells between treatments and controls. The same difference also appeared in virus amount variation in blood during infection. Gene expression analysis revealed that the apoptosis-related gene expression profile was different in the 2 groups, and also different between various organs. This study suggested that apoptosis may play an important role in duck hepatitis A virus serotype 1 infection, and apoptosis suppression might facilitate virus multiplication, resulting in the highest virus concentration in the host.
A new infusion pathway monitoring system utilizing electrostatic induced potential.
Maki, Hiromichi; Yonezawa, Yoshiharu; Ogawa, Hidekuni; Ninomiya, Ishio; Sada, Kouji; Hamada, Shingo; Hahn, Alien W; Caldwell, W Morton
2006-01-01
We have developed a new infusion pathway monitoring system employing linear integrated circuits and a low-power 8-bit single chip microcomputer. The system is available for hospital and home use and it constantly monitors the intactness of the pathway. The sensor is an electro-conductive polymer electrode wrapped around the infusion polyvinyl chloride infusion tube. This records an AC (alternating current) voltage induced on the patient's body by electrostatic coupling from the normal 100 volt, 60 Hz AC power line wiring field in the patient's room. If the injection needle or infusion tube becomes detached, then the system detects changes in the induced AC voltage and alerts the nursing station, via the nurse call system or PHS (personal handy phone System).
Synthesis and magnetic properties of bundled and dispersed Co{sub 3}O{sub 4} nanowires
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, B.B.; Wang, P.F.; Xu, J.C.
Highlights: • Co{sub 3}O{sub 4} nanowires possessed the same diameter and the different interwires distance. • All samples possessed antiferromagnetism and superparamagnetism at high temperature. • The exchange bias effect was observed at low temperature. • The surface spin coupling restrained the surface effect of magnetic nanostructures. - Abstract: The magnetic Co{sub 3}O{sub 4} nanowires were synthesized using the templates of SBA-15, and then the well-dispersed nanowires (D-wires) were separated from the bundled ordered nanowires (B-wires) with the centrifugal technique. TEM images indicated that D-wires were highly dispersed Co{sub 3}O{sub 4} nanowires and B-wires existed in bundles. All samples possessedmore » the antiferromagnetism and superparamagnetism at high temperature. After revealing the intrinsic magnetic properties of Co{sub 3}O{sub 4} nanowires with D-wires, the magnetic behavior of B-wires was discussed in detail, and then the magnetic interaction between neighboring nanowires could be deduced. The exchange bias effect from the body Co{sub 3}O{sub 4} antiferromagnetism and surface ferromagnetism was observed at low temperature. The magnetization of B-wires was higher than that of D-wires, which was attributed to the constraint of the surface spin coupling between the neighboring nanowires to the surface affect of nanostructures.« less
1981-06-01
SIGMA Y- 2 .S tE D RTzSQRT(M*V/( PHIT *UTP*(..-VA**92))) C.2=-1*THETA*RHCM*IUT’**2/2. C3-2.*SIGMAY/(SF*ALPHA) H(VB-V) /20 SUMMO.0 X1=o.0 0010JUl,21 MNCl...Yl) /(l.+Yl) )CHT. 4*3*~)/P:*v7225!*.t2 *(3.*Yl)*( PHIT *,+.49*YlW*2)Wr( PHIT *n+7225*Yl*w2)*w (-2)) 0D0- -2. *C2*Y I IP(Xl .EQ. 0.0) GO TO 50 SUM
First-generation physical map of the Culicoides variipennis (Diptera: Ceratopogonidae) genome.
Nunamaker, R A; Brown, S E; McHolland, L E; Tabachnick, W J; Knudson, D L
1999-11-01
Recombinant cosmids labeled with biotin-11-dUTP or digoxigenin by nick translation were used as in situ hybridization probes to metaphase chromosomes of Culicoides variipennis (Coquillett). Paired fluorescent signals were detected on each arm of sister chromatids and were ordered along the 3 chromosomes. Thirty-three unique probes were mapped to the 3 chromosomes of C. variipennis (2n = 6): 7 to chromosome 1, 20 to chromosome 2, and 6 to chromosome 3. This work represents the first stage in generating a physical map of the genome of C. variipennis.
Electromagnetic interference from GSM and TETRA phones with life-support medical devices.
Hietanen, Maila; Sibakov, Viktor
2007-01-01
Disturbances in hospital devices caused by cellular telephone signals were investigated. The interference sources were GSM900, GSM1800, and TETRA380 phones. The number of medical appliances tested was 23. Most measurements were taken in a semi-anechoic laboratory. To simulate the worst situation, the phones were adjusted to emit at their maximum power levels. No interference was observed if the distance from GSM1800 phone was over 5 cm. Corresponding safety distance for GSM900 phone was 70 cm, and for TETRA phones over 3 m. Hence, the use of GSM1800 type mobile phones can be considered safe, whereas GSM 900 and TETRA phones may cause considerable interference in hospital devices, which can result in life-endangering situations.
V/sub 3/Ga wire fabricated by the modified jelly roll technique
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gubser, D.U.; Francavilla, T.L.; Pande, C.S.
V/sub 3/Ga wire has been fabricated by the modified jelly roll technique for the first time. Critical current densities in magnetic fields to 22 T, critical magnetic fields, and superconducting transition temperatures are reported for this wire as a function of reaction temperature for forming the interfacial V/sub 3/Ga layer. Superconducting properties of the reacted wire are optimized for reaction temperatures between 550--580 /sup 0/C. With a reaction temperature of 580 /sup 0/C, the overall (noncopper) current density of the wire is over 10/sup 4/ amp/cm/sup 2/ at 19 T.
U.S. Navy Wire-Rope Handbook. Volume 2. Wire-Rope Analysis and Design Data
1976-01-01
beneficial from the standpoint of wire - bending stress. How- ever, there is a design trade-off here in that the smaller L/d becomes, the lower are the...wires of a rope, it is first necessary to determine the radii of curvature of the wires prior to and after bending the rope. The wire - bending stress can... wire bending stress. 4.3. CONTACT STRESSES Contact stresses in a wire rope are one of the most important determinants of its fatigue life and are, by far
Amin, Ruhul; Sharma, Sapna; Ratakonda, Sireesha
2013-01-01
Nephrolithiasis remains a major health problem in Western countries. Seventy to 80% of kidney stones are composed of calcium oxalate, and small changes in urinary oxalate affect risk of kidney stone formation. Intestinal oxalate secretion mediated by the anion exchanger SLC26A6 plays an essential role in preventing hyperoxaluria and calcium oxalate nephrolithiasis, indicating that understanding the mechanisms regulating intestinal oxalate transport is critical for management of hyperoxaluria. Purinergic signaling modulates several intestinal processes through pathways including PKC activation, which we previously found to inhibit Slc26a6 activity in mouse duodenal tissue. We therefore examined whether purinergic stimulation with ATP and UTP affects oxalate transport by human intestinal Caco-2-BBe (C2) cells. We measured [14C]oxalate uptake in the presence of an outward Cl− gradient as an assay of Cl−/oxalate exchange activity, ≥50% of which is mediated by SLC26A6. We found that ATP and UTP significantly inhibited oxalate transport by C2 cells, an effect blocked by the PKC inhibitor Gö-6983. Utilizing pharmacological agonists and antagonists, as well as PKC-δ knockdown studies, we observed that ATP inhibits oxalate transport through the P2Y2 receptor, PLC, and PKC-δ. Biotinylation studies showed that ATP inhibits oxalate transport by lowering SLC26A6 surface expression. These findings are of potential relevance to pathophysiology of inflammatory bowel disease-associated hyperoxaluria, where supraphysiological levels of ATP/UTP are expected and overexpression of the P2Y2 receptor has been reported. We conclude that ATP and UTP inhibit oxalate transport by lowering SLC26A6 surface expression in C2 cells through signaling pathways including the P2Y2 purinergic receptor, PLC, and PKC-δ. PMID:23596171
Further aspects on cellular and cordless telephones and brain tumours.
Hardell, Lennart; Mild, Kjell Hansson; Carlberg, Michael
2003-02-01
We included in a case-control study on brain tumours and mobile and cordless telephones 1,617 patients aged 20-80 years of both sexes diagnosed during January 1, 1997 to June 30, 2000. They were alive at the study time and had histopathology verified brain tumour. One matched control to each case was selected from the Swedish Population Register. The study area was the Uppsala-Orebro, Stockholm, Linköping and Göteborg medical regions of Sweden. Exposure was assessed by a questionnaire that was answered by 1,429 (88%) cases and 1,470 (91%) controls. In total use of analogue cellular telephones gave an increased risk with odds ratio (OR)=1.3, 95% confidence interval (CI)=1.04-1.6, whereas digital and cordless phones did not overall increase the risk significantly. Ipsilateral use of analogue phones gave OR=1.7, 95% CI=1.2-2.3, digital phones OR=1.3, 95% CI=1.02-1.8 and cordless phones OR=1.2, 95% CI=0.9-1.6. The risk for ipsilateral use was significantly increased for astrocytoma for all studied phone types, analogue phones OR=1.8,95% CI=1.1-3.2, digital phones OR=1.8, 95% CI=1.1-2.8, cordless phones OR=1.8, 95% CI=1.1-2.9. Use of a telephone on the opposite side of the brain was not associated with a significantly increased risk for brain tumours. Regarding anatomical area of the tumour and exposure to microwaves, the risk was increased for tumours located in the temporal area on the same side of the brain that was used during phone calls, significantly so for analogue cellular telephones OR=2.3, 95% CI=1.2-4.1. For acoustic neurinoma OR=4.4, 95% CI=2.1-9.2 was calculated among analogue cellular telephone users. When duration of use was analysed as a continuous variable in the total material, the risk increased per year for analogue phones with OR=1.04, 95% CI=1.01-1.08. For astrocytoma and ipsilateral use the trend was for analogue phones OR=1.10, 95% CI=1.02-1.19, digital phones OR=1.11, 95% CI=1.01-1.22, and cordless phones OR=1.09, 95% CI=1.01-1.19. There was a tendency of a shorter tumour induction period for ipsilateral exposure to microwaves than for contralateral, which may indicate a tumour promotor effect.
A remote patient monitoring system using a Java-enabled 3G mobile phone.
Zhang, Pu; Kogure, Yuichi; Matsuoka, Hiroki; Akutagawa, Masatake; Kinouchi, Yohsuke; Zhang, Qinyu
2007-01-01
Telemedicine systems have become an important supporting for the medical staffs. As the development of the mobile phones, it is possible to apply the mobile phones to be a part of telemedicine systems. We developed an innovative Remote Patient Monitoring System using a Java-enabled 3G mobile phone. By using this system, doctors can monitor the vital biosignals of patients in ICU/CCU, such as ECG, RESP, SpO2, EtCO2 and so on by using the real-time waveform and data monitoring and list trend data monitoring functions of installed Java jiglet application on the mobile phone. Futhermore, doctors can check the patients' information by using the patient information checking function. The 3G mobile phone used has the ability to implement the application as the same time as being used to mak a voice call. Therefore, the doctor can get more and more information both from the browsing the screen of the mobile phone and the communicating with the medical staffs who are beside the patients and the monitors. The system can be conducted to evaluate the diagnostic accuracy, efficiency, and safety of telediagnosis.
Preliminary Design of an Autonomous Amphibious System
2016-09-01
changing vehicle dynamics will require innovative new autonomy algorithms. The developed software architecture, drive-by- wire kit, and supporting...COMMUNICATIONS ARCHITECTURE .................................................12 3.3 DRIVE-BY- WIRE DESIGN...SOFTWARE MATURATION PLANS ......................................................17 4.2 DRIVE-BY- WIRE PLANNED REFINEMENT
47 CFR 97.305 - Authorized emission types.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Standards see § 97.307(f), paragraph: MF: 160 m Entire band RTTY, data (3). 160 m Entire band Phone, image (1), (2). HF: 80 m Entire band RTTY, data (3), (9). 75 m Entire band Phone, image (1), (2). 40 m 7.000-7.100 MHz RTTY, data (3), (9) 40 m 7.075-7.100 MHz Phone, image (1), (2), (9), (11) 40 m 7.100-7...
47 CFR 97.305 - Authorized emission types.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Standards see § 97.307(f), paragraph: MF: 160 m Entire band RTTY, data (3). 160 m Entire band Phone, image (1), (2). HF: 80 m Entire band RTTY, data (3), (9). 75 m Entire band Phone, image (1), (2). 60 m 5...), (9) 40 m 7.075-7.100 MHz Phone, image (1), (2), (9), (11) 40 m 7.100-7.125 MHz RTTY, data (3), (9) 40...
47 CFR 97.305 - Authorized emission types.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Standards see § 97.307(f), paragraph: MF: 160 m Entire band RTTY, data (3). 160 m Entire band Phone, image (1), (2). HF: 80 m Entire band RTTY, data (3), (9). 75 m Entire band Phone, image (1), (2). 40 m 7.000-7.100 MHz RTTY, data (3), (9) 40 m 7.075-7.100 MHz Phone, image (1), (2), (9), (11) 40 m 7.100-7...
Zhu, Yongjian; Jin, Wen; Liu, Hui; Peng, Deqing; Ding, Zheyuan; Tang, Zhuxiao; Zhu, Liangliang; Yu, Yunxian
2016-01-01
To explore the effects of radiofrequency-electromagnetic fields (RF-EMFs) from mobile phones on depression and anxiety after titanium mesh cranioplasty among patients with traumatic brain injury (TBI). Two hundred and twenty patients with TBI and titanium mesh cranioplasty who were hospitalized from 2008-2012 were recruited in this study. From November-December 2012, the relevant information was surveyed including socio-demographic characteristics, lifestyle variables, injury-related information, RF-EMF exposure of mobile phone, Self-rating Depression Scale (SDS) and Self-rating Anxiety Scale (SAS). Associations of RF-EMFs exposure after titanium mesh cranioplasty with SAS and SDS were respectively estimated by multivariable linear regression models. The patients with long durations of mobile phone use (β = -6.6, p = 0.002), long individual call duration (β = -5.3, p = 0.012), more daily calls (β = -3.6, p = 0.027), invariably answer call immediately (β = -3.9, p = 0.022) and high comprehensive exposure level (β = -4.8, p = 0.003) had a lower score of depression compared with those without a mobile phone. Moreover, an ipsilateral and contralateral answering phone enhanced the protective effect on depression. Individuals with a long duration of mobile phone use had a lower score of anxiety (β = -4.2, p = 0.008), while those with a bilateral answering phone had higher anxiety (β = 3.9, p = 0.012) in comparison to those without a mobile phone. RF-EMFs after cranioplasty were significantly associated with the lower risk of depression and anxiety status among patients with TBI. Chronic and frequent RF-EMFs exposure may improve psychiatric disorders among patients with TBI.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
This report consists of vugraphs of the presentations at the conference. The conference was divided into the following sessions: (1) First Generation Wire Development: Status and Issues; (2) First Generation Wire in Pre-Commercial Prototypes; (3) Second Generation Wire Development: Private Sector Progress and Issues; (4) Second Generation Wire Development: Federal Laboratories; and (5) Fundamental Research Issues for HTS Wire Development.
78 FR 27310 - Airworthiness Directives; the Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-10
... wiring; installation of new circuit breakers, relays, relay connectors, and wiring; and replacement of... Installation of wiring and changing 36 work-hours x $85 per $2,503 $5,563 $328,217 ELMS panel wiring. hour = $3... flames in the passenger cabin of various transport category airplanes related to the wiring for the...
Degradation of orthodontic wires under simulated cariogenic and erosive conditions.
Jaber, Laura Cavalcante Lima; Rodrigues, José Augusto; Amaral, Flávia Lucisano Botelho; França, Fabiana Mantovani Gomes; Basting, Roberta Tarkany; Turssi, Cecilia Pedroso
2014-01-01
This study examined the effect of cariogenic and erosive challenges (CCs and ECs, respectively) on the degradation of copper-nickel-titanium (CuNiTi) orthodontic wires. Sixty wire segments were divided into four treatment groups and exposed to CCs, ECs, artificial saliva, or dry storage (no-treatment control). CC and EC were simulated using a demineralizing solution (pH 4.3) and a citric acid solution (pH 2.3), respectively. Following treatment, the average surface roughness (Ra) of the wires was assessed, and friction between the wires and a passive self-ligating bracket was measured. CuNiTi wires subjected to ECs exhibited significantly higher Ra values than did those that were stored in artificial saliva. In contrast, surface roughness was not affected by CCs. Finally, friction between the treated wires and brackets was not affected by ECs or CCs. Our results indicate that CuNiTi orthodontic wires may suffer degradation within the oral cavity, as ECs increased the surface roughness of these wires. However, rougher surfaces did not increase friction between the wire and the passive self-ligating bracket.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gung, C.Y.
1993-01-01
Energy dissipation, which is also called AC loss, of a composite multifilamentary superconducting wire is one of the most fundamental concerns in building a stable superconducting magnet. Characterization and reduction of AC losses are especially important in designing a superconducting magnet for generating transient magnetic fields. The goal of this thesis is to improve the understanding of AC-loss properties of superconducting wires developed for high-current ramp-field magnet applications. The major tasks include: (1) building an advanced AC-loss measurement system, (2) measuring AC losses of superconducting wires under simulated pulse magnet operations, (3) developing an analytical model for explaining the newmore » AC-loss properties found in the experiment, and (4) developing a computational methodology for comparing AC losses of a superconducting wire with those of a cable for a superconducting pulse magnet. A new experimental system using an isothermal calorimetric method was designed and constructed to measure the absolute AC losses in a composite superconductor. This unique experimental setup is capable of measuring AC losses of a brittle Nb{sub 3}Sn wire carrying high AC current in-phase with a large-amplitude pulse magnetic field. Improvements of the accuracy and the efficiency of this method are discussed. Three different types of composite wire have been measured: a Nb{sub 3}Sn modified jelly-roll (MJR) internal-tin wire used in a prototype ohmic heating coil, a Nb{sub 3}Sn internal-tin wire developed for a fusion reactor ohmic heating coil, and a NbTi wire developed for the magnets in a particle accelerator. The cross sectional constructions of these wires represent typical commercial wires manufactured for pulse magnet applications.« less
Saravanakumar, Balasubramaniam; Jayaseelan, Santhana Sivabalan; Seo, Min-Kang; Kim, Hak-Yong; Kim, Byoung-Suhk
2017-12-07
Wire type supercapacitors with high energy and power densities have generated considerable interest in wearable applications. Herein, we report a novel NiCo 2 S 4 -decorated 3D, porous Ni film@Ni wire electrode for high performance supercapacitor application. In this work, a facile method is introduced to fabricate a 3D, porous Ni film deposited on a Ni wire as a flexible electrode, followed by decoration with NiCo 2 S 4 as an electroactive material. The fabricated NiCo 2 S 4 -decorated 3D, porous Ni film@Ni wire electrode displays a superior performance with an areal and volumetric capacitance of 1.228 F cm -2 and 199.74 F cm -3 , respectively, at a current density of 0.2 mA cm -1 with a maximum volumetric energy and power density (E V : 6.935 mW h cm -3 ; P V : 1.019 W cm -3 ). Finally, the solid state asymmetric wire type supercapacitor is fabricated using the fabricated NiCo 2 S 4 -decorated 3D, porous Ni film@Ni wire as a positive electrode and N-doped reduced graphene oxide (N-rGO) as a negative electrode and this exhibits good areal and volumetric capacitances of C A : 0.12 F cm -2 and C V : 19.57 F cm -2 with a higher rate capability (92%). This asymmetric wire type supercapacitor demonstrates a low leakage current and self-discharge with a maximum volumetric energy (E V : 5.33 mW h cm -3 ) and power (P V : 855.69 mW cm -3 ) density.
EEG Changes Due to Experimentally Induced 3G Mobile Phone Radiation
Roggeveen, Suzanne; van Os, Jim; Viechtbauer, Wolfgang; Lousberg, Richel
2015-01-01
The aim of this study was to investigate whether a 15-minute placement of a 3G dialing mobile phone causes direct changes in EEG activity compared to the placement of a sham phone. Furthermore, it was investigated whether placement of the mobile phone on the ear or the heart would result in different outcomes. Thirty-one healthy females participated. All subjects were measured twice: on one of the two days the mobile phone was attached to the ear, the other day to the chest. In this single-blind, cross-over design, assessments in the sham phone condition were conducted directly preceding and following the mobile phone exposure. During each assessment, EEG activity and radiofrequency radiation were recorded jointly. Delta, theta, alpha, slowbeta, fastbeta, and gamma activity was computed. The association between radiation exposure and the EEG was tested using multilevel random regression analyses with radiation as predictor of main interest. Significant radiation effects were found for the alpha, slowbeta, fastbeta, and gamma bands. When analyzed separately, ear location of the phone was associated with significant results, while chest placement was not. The results support the notion that EEG alterations are associated with mobile phone usage and that the effect is dependent on site of placement. Further studies are required to demonstrate the physiological relevance of these findings. PMID:26053854
EEG Changes Due to Experimentally Induced 3G Mobile Phone Radiation.
Roggeveen, Suzanne; van Os, Jim; Viechtbauer, Wolfgang; Lousberg, Richel
2015-01-01
The aim of this study was to investigate whether a 15-minute placement of a 3G dialing mobile phone causes direct changes in EEG activity compared to the placement of a sham phone. Furthermore, it was investigated whether placement of the mobile phone on the ear or the heart would result in different outcomes. Thirty-one healthy females participated. All subjects were measured twice: on one of the two days the mobile phone was attached to the ear, the other day to the chest. In this single-blind, cross-over design, assessments in the sham phone condition were conducted directly preceding and following the mobile phone exposure. During each assessment, EEG activity and radiofrequency radiation were recorded jointly. Delta, theta, alpha, slowbeta, fastbeta, and gamma activity was computed. The association between radiation exposure and the EEG was tested using multilevel random regression analyses with radiation as predictor of main interest. Significant radiation effects were found for the alpha, slowbeta, fastbeta, and gamma bands. When analyzed separately, ear location of the phone was associated with significant results, while chest placement was not. The results support the notion that EEG alterations are associated with mobile phone usage and that the effect is dependent on site of placement. Further studies are required to demonstrate the physiological relevance of these findings.
Eslami, J.; Ghafaripour, F.; Mortazavi, S.A.R.; Mortazavi, S.M.J.; Shojaei-fard, M.B.
2015-01-01
Background People who use home blood glucose monitors may use their mobile phones in the close vicinity of medical devices. This study is aimed at investigating the effect of the signal strength of 900 MHz GSM mobile phones on the accuracy of home blood glucose monitors. Methods Sixty non-diabetic volunteer individuals aged 21 - 28 years participated in this study. Blood samples were analyzed for glucose level by using a common blood glucose monitoring system. Each blood sample was analyzed twice, within ten minutes in presence and absence of electromagnetic fields generated by a common GSM mobile phone during ringing. Blood samples were divided into 3 groups of 20 samples each. Group 1: exposure to mobile phone radiation with weak signal strength. Group2: exposure to mobile phone radiation with strong signal strength. Group3: exposure to a switched–on mobile phone with no signal strength. Results The magnitude of the changes in the first, second and third group between glucose levels of two measurements (׀ΔC׀) were 7.4±3.9 mg/dl, 10.2±4.5 mg/dl, 8.7±8.4 mg/dl respectively. The difference in the magnitude of the changes between the 1st and the 3rd groups was not statistically significant. Furthermore, the difference in the magnitude of the changes between the 2nd and the 3rd groups was not statistically significant. Conclusion Findings of this study showed that the signal strength of 900 MHz GSM mobile phones cannot play a significant role in changing the accuracy of home blood glucose monitors. PMID:26688798
Eslami, J; Ghafaripour, F; Mortazavi, S A R; Mortazavi, S M J; Shojaei-Fard, M B
2015-12-01
People who use home blood glucose monitors may use their mobile phones in the close vicinity of medical devices. This study is aimed at investigating the effect of the signal strength of 900 MHz GSM mobile phones on the accuracy of home blood glucose monitors. Sixty non-diabetic volunteer individuals aged 21 - 28 years participated in this study. Blood samples were analyzed for glucose level by using a common blood glucose monitoring system. Each blood sample was analyzed twice, within ten minutes in presence and absence of electromagnetic fields generated by a common GSM mobile phone during ringing. Blood samples were divided into 3 groups of 20 samples each. Group 1: exposure to mobile phone radiation with weak signal strength. Group2: exposure to mobile phone radiation with strong signal strength. Group3: exposure to a switched-on mobile phone with no signal strength. The magnitude of the changes in the first, second and third group between glucose levels of two measurements (׀ΔC׀) were 7.4±3.9 mg/dl, 10.2±4.5 mg/dl, 8.7±8.4 mg/dl respectively. The difference in the magnitude of the changes between the 1st and the 3rd groups was not statistically significant. Furthermore, the difference in the magnitude of the changes between the 2nd and the 3rd groups was not statistically significant. Findings of this study showed that the signal strength of 900 MHz GSM mobile phones cannot play a significant role in changing the accuracy of home blood glucose monitors.
Cell phones to collect pregnancy data from remote areas in Liberia.
Lori, Jody R; Munro, Michelle L; Boyd, Carol J; Andreatta, Pamela
2012-09-01
To report findings on knowledge and skill acquisition following a 3-day training session in the use of short message service (SMS) texting with non- and low-literacy traditional midwives. A pre- and post-test study design was used to assess knowledge and skill acquisition with 99 traditional midwives on the use of SMS texting for real-time, remote data collection in rural Liberia, West Africa. Paired sample t-tests were conducted to establish if overall mean scores varied significantly from pre-test to immediate post-test. Analysis of variance was used to compare means across groups. The nonparametric McNemar's test was used to determine significant differences between the pre-test and post-test values of each individual step involved in SMS texting. Pearson's chi-square test of independence was used to examine the association between ownership of cell phones within a family and achievement of the seven tasks. The mean increase in cell phone knowledge scores was 3.67, with a 95% confidence interval ranging from 3.39 to 3.95. Participants with a cell phone in the family did significantly better on three of the seven tasks in the pre-test: "turns cell on without help" (χ(2) (1) = 9.15, p= .003); "identifies cell phone coverage" (χ(2) (1) = 5.37, p= .024); and "identifies cell phone is charged" (χ(2) (1) = 4.40, p= .042). A 3-day cell phone training session with low- and nonliterate traditional midwives in rural Liberia improved their ability to use mobile technology for SMS texting. Mobile technology can improve data collection accessibility and be used for numerous health care and public health issues. Cell phone accessibility holds great promise for collecting health data in low-resource areas of the world. © 2012 Sigma Theta Tau International.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Attachment of ground conductors and ground check wires to equipment frames; use of separate connections. 77.902-3 Section 77.902-3 Mineral...-Voltage Alternating Current Circuits § 77.902-3 Attachment of ground conductors and ground check wires to...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Attachment of ground conductors and ground check wires to equipment frames; use of separate connections. 77.902-3 Section 77.902-3 Mineral...-Voltage Alternating Current Circuits § 77.902-3 Attachment of ground conductors and ground check wires to...
2011-01-01
Background Despite the significant health benefits of regular physical activity, approximately half of American adults, particularly women and minorities, do not meet the current physical activity recommendations. Mobile phone technologies are readily available, easily accessible and may provide a potentially powerful tool for delivering physical activity interventions. However, we need to understand how to effectively apply these mobile technologies to increase and maintain physical activity in physically inactive women. The purpose of this paper is to describe the study design and protocol of the mPED (mobile phone based physical activity education) randomized controlled clinical trial that examines the efficacy of a 3-month mobile phone and pedometer based physical activity intervention and compares two different 6-month maintenance interventions. Methods A randomized controlled trial (RCT) with three arms; 1) PLUS (3-month mobile phone and pedometer based physical activity intervention and 6-month mobile phone diary maintenance intervention), 2) REGULAR (3-month mobile phone and pedometer based physical activity intervention and 6-month pedometer maintenance intervention), and 3) CONTROL (pedometer only, but no intervention will be conducted). A total of 192 physically inactive women who meet all inclusion criteria and successfully complete a 3-week run-in will be randomized into one of the three groups. The mobile phone serves as a means of delivering the physical activity intervention, setting individualized weekly physical activity goals, and providing self-monitoring (activity diary), immediate feedback and social support. The mobile phone also functions as a tool for communication and real-time data capture. The primary outcome is objectively measured physical activity. Discussion If efficacy of the intervention with a mobile phone is demonstrated, the results of this RCT will be able to provide new insights for current behavioral sciences and mHealth. Trial Registration ClinicalTrials.gov#:NCTO1280812 PMID:22168267
Fukuoka, Yoshimi; Komatsu, Judith; Suarez, Larry; Vittinghoff, Eric; Haskell, William; Noorishad, Tina; Pham, Kristin
2011-12-14
Despite the significant health benefits of regular physical activity, approximately half of American adults, particularly women and minorities, do not meet the current physical activity recommendations. Mobile phone technologies are readily available, easily accessible and may provide a potentially powerful tool for delivering physical activity interventions. However, we need to understand how to effectively apply these mobile technologies to increase and maintain physical activity in physically inactive women. The purpose of this paper is to describe the study design and protocol of the mPED (mobile phone based physical activity education) randomized controlled clinical trial that examines the efficacy of a 3-month mobile phone and pedometer based physical activity intervention and compares two different 6-month maintenance interventions. A randomized controlled trial (RCT) with three arms; 1) PLUS (3-month mobile phone and pedometer based physical activity intervention and 6-month mobile phone diary maintenance intervention), 2) REGULAR (3-month mobile phone and pedometer based physical activity intervention and 6-month pedometer maintenance intervention), and 3) CONTROL (pedometer only, but no intervention will be conducted). A total of 192 physically inactive women who meet all inclusion criteria and successfully complete a 3-week run-in will be randomized into one of the three groups. The mobile phone serves as a means of delivering the physical activity intervention, setting individualized weekly physical activity goals, and providing self-monitoring (activity diary), immediate feedback and social support. The mobile phone also functions as a tool for communication and real-time data capture. The primary outcome is objectively measured physical activity. If efficacy of the intervention with a mobile phone is demonstrated, the results of this RCT will be able to provide new insights for current behavioral sciences and mHealth. ClinicalTrials.gov#:NCTO1280812.
NASA Astrophysics Data System (ADS)
Zheng, Maobo; Xu, Guangquan; Liu, Debao; Zhao, Yue; Ning, Baoqun; Chen, Minfang
2018-03-01
Due to their excellent biocompatibility and biodegradability, magnesium alloy wires have attracted much attention for biomaterial applications including orthopedic K-wires and sutures in wound closure. In this study, Mg-3Zn-0.2Ca alloy wires were prepared by cold drawing combined with proper intermediate annealing process. Microstructures, texture, mechanical properties and corrosion behavior of Mg-3Zn-0.2Ca alloy wire in a simulated body fluid were investigated. The results showed that the secondary phase and average grain size of the Mg-3Zn-0.2Ca alloy were refined in comparison with the as-extruded alloy and a strong (0002)<10-10>//DD basal fiber texture system was formed after multi-pass cold drawing. After the annealing, most of the basal planes were tilted to the drawing direction (DD) by about 35°, presenting the characteristics of random texture, and the texture intensity decreased. The as-annealed wire shows good mechanical properties with the ultimate tensile strength (UTS), yield strength (YS) and elongation of 253 ± 8.5 MPa, 212 ± 11.3 MPa and 9.2 ± 0.9%, respectively. Electrochemical and hydrogen evolution measurements showed that the corrosion resistance of the Mg-3Zn-0.2Ca alloy wire was improved after the annealing. The immersion test indicated that the Mg-3Zn-0.2Ca wire exhibited uniform corrosion behavior during the initial period of immersion, but then exhibited local corrosion behavior.
1986-01-01
A technique has been developed for localizing hybrids formed in situ on semi-thin and ultrathin sections of Lowicryl K4M-embedded tissue. Biotinylated dUTP (Bio-11-dUTP and/or Bio-16-dUTP) was incorporated into mitochondrial rDNA and small nuclear U1 probes by nick- translation. The probes were hybridized to sections of Drosophila ovaries and subsequently detected with an anti-biotin antibody and protein A-gold complex. On semi-thin sections, probe detection was achieved by amplification steps with anti-protein A antibody and protein A-gold with subsequent silver enhancement. At the electron microscope level, specific labeling was obtained over structures known to be the site of expression of the appropriate genes (i.e., either over mitochondria or over nuclei). The labeling pattern at the light microscope level (semi-thin sections) was consistent with that obtained at the electron microscope level. The described nonradioactive procedures for hybrid detection on Lowicryl K4M-embedded tissue sections offer several advantages: rapid signal detection: superior morphological preservation and spatial resolution; and signal-to-noise ratios equivalent to radiolabeling. PMID:3084498
González, Claudia; Espinosa, Marisol; Sánchez, María Trinidad; Droguett, Karla; Ríos, Mariana; Fonseca, Ximena; Villalón, Manuel
2013-01-01
Background. Mucociliary transport (MCT) is a defense mechanism of the airway. To study the underlying mechanisms of MCT, we have both developed an experimental model of cultures, from human adenoid tissue of ciliated and secretory cells, and characterized the response to local chemical signals that control ciliary activity and the secretion of respiratory mucins in vitro. Materials and Methods. In ciliated cell cultures, ciliary beat frequency (CBF) and intracellular Ca2+ levels were measured in response to ATP, UTP, and adenosine. In secretory cultures, mucin synthesis and secretion were identified by using immunodetection. Mucin content was taken from conditioned medium and analyzed in the presence or absence of UTP. Results. Enriched ciliated cell monolayers and secretory cells were obtained. Ciliated cells showed a basal CBF of 10.7 Hz that increased significantly after exposure to ATP, UTP, or adenosine. Mature secretory cells showed active secretion of granules containing different glycoproteins, including MUC5AC. Conclusion. Culture of ciliated and secretory cells grown from adenoid epithelium is a reproducible and feasible experimental model, in which it is possible to observe ciliary and secretory activities, with a potential use as a model to understand mucociliary transport control mechanisms. PMID:23484122
Hishikawa, Yoshitaka; An, Shucai; Yamamoto-Fukuda, Tomomi; Shibata, Yasuaki; Koji, Takehiko
2009-01-01
In situ polymerase chain reaction (in situ PCR), which can detect a few copies of genes within a cell by amplifying the target gene, was developed to better understand the biological functions of tissues. In this study, we optimized the protocol conditions for the detection of X chromosome-linked phosphoglycerate kinase-1 (pgk-1) gene in paraffin-embedded sections of mouse reproductive organs. The effects of various concentrations of proteinase K (PK) and PCR cycle numbers were examined. To label the amplified DNA, we used digoxigenin-dUTP (Dig), Cy-3-dUTP (Cy-3), or FluorX-dCTP (FluorX). The optimal concentration of PK was 50 µg/ml for the ovary and 10 µg/ml for the testis. Ten PCR cycles were optimal for Dig and 25 cycles were optimal for FluorX and Cy-3 in the ovary and testis. The signal-to-noise ratio of FluorX and Cy-3 for ovarian tissue was better than that of Dig. Using the above conditions, we detected 1–4 and 1–2 spots of pgk-1 in the nuclei of granulosa and germ cells, respectively. Our results indicate that in situ PCR is useful for detecting a specific gene in paraffin-embedded sections under optimized conditions of both PCR cycle number and PK concentration. PMID:19492023
Investigation of OSL signal of resistors from mobile phones for accidental dosimetry
NASA Astrophysics Data System (ADS)
Mrozik, A.; Marczewska, B.; Bilski, P.; Gieszczyk, W.
2014-12-01
Resistors from mobile phones, usually located near the human body, are considered as individual dosimeters of ionizing radiation in emergency situations. The resistors contain Al2O3, which is optically stimulated luminescence (OSL) material sensitive to ionizing radiation. This work is focused on determination of dose homogeneity within a mobile phones which was carried out by OSL measurements of resistors placed in different parts inside the mobile phone. Separate, commercially available resistors, similar in the shape and size to the resistors from circuit board of the studied mobile phone, were situated in different locations inside it. The irradiations were performed in uniform 60Co and 137Cs radiation fields, with the mobile phones connected and not connected to the cellular network. The dose decrease of 9% was measured for original resistors situated between layer of copper-clad laminate and battery, in comparison to the dose at the front of the phone. The resistors showed the lower signal when the mobile phone was connected to the cellular network, due to higher temperature inside the housing. The profile of fading was investigated within 3 month period for resistors irradiated with 1 Gy of gamma rays to estimate of the fading coefficient.
An Obstacle Alerting System for Agricultural Application
NASA Technical Reports Server (NTRS)
DeMaio, Joe
2003-01-01
Wire strikes are a significant cause of helicopter accidents. The aircraft most at risk are aerial applicators. The present study examines the effectiveness of a wire alert delivered by way of the lightbar, a GPS-based guidance system for aerial application. The alert lead-time needed to avoid an invisible wire is compared with that to avoid a visible wire. A flight simulator was configured to simulate an agricultural application helicopter. Two pilots flew simulated spray runs in fields with visible wires, invisible wires, and no wires. The wire alert was effective in reducing wire strikes. A lead-time of 3.5 sec was required for the alert to be effective. The lead- time required was the same whether the pilot could see the wire or not.
2009-01-01
Central University 300 Jung-da Rd., Jhongli, Taiwan 32001 phone: +886-3-422-3354, fax: +886-3-422-2894, email: kkliu@ncu.edu.tw Wen-Son Chiang...Tainan Hydraulics Laboratory, National Cheng-Kung University 500 An-Ming Road Sec. 3, Tainan, Taiwan 701 phone: +886-6-237-1938 ext 232, fax: +886-6...Taoyuan, Taiwan 32001 phone: +886-3-422-7151 ext 65690, fax: +886-3-422-2894, email: hchien@ncu.edu.tw Shu-Kun Hsu Department of Earth Science
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhai, Y.; D'Hauthuille, L.; Barth, C.
High-field superconducting magnets play a very important role in many large-scale physics experiments, particularly particle colliders and fusion confinement devices such as Large Hadron Collider (LHC) and International Thermonuclear Experimental Reactor (ITER). The two most common superconductors used in these applications are NbTi and Nb 3Sn. Nb 3Sn wires are favored because of their significantly higher J c (critical current density) for higher field applications. The main disadvantage of Nb 3Sn is that the superconducting performance of the wire is highly strain sensitive and it is very brittle. This strain sensitivity is strongly influenced by two factors: plasticity and crackedmore » filaments. Cracks are induced by large stress concentrators that can be traced to the presence of voids in the wire. We develop detailed 2-D and 3-D finite-element models containing wire filaments and different possible distributions of voids in a bronze-route Nb 3Sn wire. We apply compressive transverse loads for various cases of void distributions to simulate the stress and strain response of a Nb 3Sn wire under the Lorentz force. Furthermore, this paper improves our understanding of the effect voids have on the Nb 3Sn wire's mechanical properties, and in so, the connection between the distribution of voids and performance degradation such as the correlation between irreversible strain limit and the void-induced local stress concentrations.« less
Beckman, S L; Zulewska, J; Newbold, M; Barbano, D M
2010-10-01
Most current research has focused on using ceramic microfiltration (MF) membranes for micellar casein concentrate production, but little research has focused on the use of polymeric spiral-wound (SW) MF membranes. A method for the production of a serum protein (SP)-reduced micellar casein concentrate using SW MF was compared with a ceramic MF membrane. Pasteurized (79°C, 18s) skim milk (1,100 kg) was microfiltered at 50°C [about 3 × concentration] using a 0.3-μm polyvinylidene fluoride spiral-wound membrane, bleed-and-feed, 3-stage process, using 2 diafiltration stages, where the retentate was diluted 1:2 with reverse osmosis water. Skim milk, permeate, and retentate were analyzed for SP content, and the reduction of SP from skim milk was determined. Theoretically, 68% of the SP content of skim milk can be removed using a single-stage 3× MF. If 2 subsequent water diafiltration stages are used, an additional 22% and 7% of the SP can be removed, respectively, giving a total SP removal of 97%. Removal of SP greater than 95% has been achieved using a 0.1-μm pore size ceramic uniform transmembrane pressure (UTP) MF membrane after a 3-stage MF with diafiltration process. One stage of MF plus 2 stages of diafiltration of 50°C skim milk using a polyvinylidene fluoride polymeric SW 0.3-μm membrane yielded a total SP reduction of only 70.3% (stages 1, 2, and 3: 38.6, 20.8, and 10.9%, respectively). The SP removal rate for the polymeric SW MF membrane was lower in all 3 stages of processing (stages 1, 2, and 3: 0.05, 0.04, and 0.03 kg/m(2) per hour, respectively) than that of the comparable ceramic UTP MF membrane (stages 1, 2, and 3: 0.30, 0.11, and 0.06 kg/m(2) per hour, respectively), indicating that SW MF is less efficient at removing SP from 50°C skim milk than the ceramic UTP system. To estimate the number of steps required for the SW system to reach 95% SP removal, the third-stage SP removal rate (27.4% of the starting material SP content) was used to extrapolate that an additional 5 water diafiltration stages would be necessary, for a total of 8 stages, to remove 95% of the SP from skim milk. The 8-plus stages necessary to remove >95% SP for the SW MF membrane would create more permeate and a lengthier process than required with ceramic membranes. Copyright © 2010 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Kotris, Ivan; Drenjančević, Domagoj; Talapko, Jasminka; Bukovski, Suzana
2017-02-01
Aim To identify and investigate a difference between microorganisms present on intensive care unit (ICU) health care workers' (HCW, doctors, nurses or medical technicians) and medical students' mobile phones as well as to investigate a difference between the frequency and the way of cleaning mobile phones. Methods Fifty swabs were collected from HCWs who work in the ICU (University Hospital Centre Osijek) and 60 swabs from medical students (School of Medicine, University of Osijek). Microorganisms were identified according to standard microbiological methods and biochemical tests to the genus/species level. Results Out of 110 processed mobile phones, mobile phones microorganisms were not detected on 25 (22.7%), 15 (25%) students' and 10 (20%) HCW's mobile phones. No statistically significant difference was found between the number of isolated bacteria between the HCW' and students' mobile phones (p>0.05). Statistically significant difference was found between both HCW and students and frequency of cleaning their mobile phones (p<0.001). A significant difference was also obtained with the way of cleaning mobile phones between HCWs and students (p<0.001). Conclusion The most common isolated microorganisms in both groups were coagulase-negative staphylococci (CoNS) and Staphylococcus aureus. Most HCWs cleaned their mobile phones at least once a week, 35 (52.0%), and most medical students several times per year, 20 (33.3%). HCW clean their mobile phones with alcohol disinfectant in 26 (40.0%) and medical students with dry cloth in 20 (33.3%) cases. Copyright© by the Medical Assotiation of Zenica-Doboj Canton.
Kesari, Kavindra Kumar; Meena, Ramovatar; Nirala, Jayprakash; Kumar, Jitender; Verma, H N
2014-03-01
Cell phone radiation exposure and its biological interaction is the present concern of debate. Present study aimed to investigate the effect of 3G cell phone exposure with computer controlled 2-D stepper motor on 45-day-old male Wistar rat brain. Animals were exposed for 2 h a day for 60 days by using mobile phone with angular movement up to zero to 30°. The variation of the motor is restricted to 90° with respect to the horizontal plane, moving at a pre-determined rate of 2° per minute. Immediately after 60 days of exposure, animals were scarified and numbers of parameters (DNA double-strand break, micronuclei, caspase 3, apoptosis, DNA fragmentation, expression of stress-responsive genes) were performed. Result shows that microwave radiation emitted from 3G mobile phone significantly induced DNA strand breaks in brain. Meanwhile a significant increase in micronuclei, caspase 3 and apoptosis were also observed in exposed group (P < 0.05). Western blotting result shows that 3G mobile phone exposure causes a transient increase in phosphorylation of hsp27, hsp70, and p38 mitogen-activated protein kinase (p38MAPK), which leads to mitochondrial dysfunction-mediated cytochrome c release and subsequent activation of caspases, involved in the process of radiation-induced apoptotic cell death. Study shows that the oxidative stress is the main factor which activates a variety of cellular signal transduction pathways, among them the hsp27/p38MAPK is the pathway of principle stress response. Results conclude that 3G mobile phone radiations affect the brain function and cause several neurological disorders.
Xu, Xiulian; Cao, Yingjuan; Luan, Xiaorong
2014-01-01
Background: This study aims to apply 4G wireless network in the remote diagnosis of stoma complications for the first time. Background: Remote diagnosis and nursing care for a variety of illnesses are urgently needed in clinical settings. Objectives: Combining with relevant clinical manifestations, an Android phone-based intelligent diagnosis system was designed to construct a universe, easy access to exploitation and human-computer interaction database and exploitation environment for applications and programs. Methods: “Production rule” and forward reasoning method were utilized to design arborescence structures and logic reasoner associated with stoma complications. Stoma physicians were responsible for delivering evaluation scores on patients’ health status using analytic hierarchy process. The emphasis of this study is to exploit an “Android phone-based system for remote diagnosis of stoma”, which is of certain universe usage. Results: Such system was tested in the Medicine Information Center of Qilu Hospital of Shandong University and initially applied in the city of De Zhou, Shandong province, China. Conclusions: These results collectively demonstrated that the system is easy to carry, of high utility and free from the limitations of wire network environment, etc. It provides clinical evidence for establishing a novel type model for the exchange between patients and physicians. PMID:25550986
Magnetization and magnetoresistance of common alloy wires used in cryogenic instrumentation.
Abrecht, M; Adare, A; Ekin, J W
2007-04-01
We present magnetization and magnetoresistance data at liquid-helium and liquid-nitrogen temperatures for wire materials commonly used for instrumentation wiring of specimens, sensors, and heaters in cryogenic probes. The magnetic susceptibilities in Systeme International units at 4.2 K were found to be: Manganin 1.25x10(-2), Nichrome 5.6x10(-3), and phosphor bronze -3.3x10(-5), indicating that phosphor bronze is the most suitable for high-field applications. We also show the ferromagnetic hysteresis loop of Constantan wire at liquid-helium temperature. The magnetoresistance of these four wires was relatively small: the changes in resistance at 4 K due to a 10 T transverse magnetic field are -2.56% for Constantan, -2.83% for Manganin, +0.69% for Nichrome, and +4.5% for phosphor bronze, compared to about +188% for a typical copper wire under the same conditions.
Magnetization and magnetoresistance of common alloy wires used in cryogenic instrumentation
NASA Astrophysics Data System (ADS)
Abrecht, M.; Adare, A.; Ekin, J. W.
2007-04-01
We present magnetization and magnetoresistance data at liquid-helium and liquid-nitrogen temperatures for wire materials commonly used for instrumentation wiring of specimens, sensors, and heaters in cryogenic probes. The magnetic susceptibilities in Systeme International units at 4.2 K were found to be: Manganin 1.25×10-2, Nichrome 5.6×10-3, and phosphor bronze -3.3×10-5, indicating that phosphor bronze is the most suitable for high-field applications. We also show the ferromagnetic hysteresis loop of Constantan wire at liquid-helium temperature. The magnetoresistance of these four wires was relatively small: the changes in resistance at 4 K due to a 10 T transverse magnetic field are -2.56% for Constantan, -2.83% for Manganin, +0.69% for Nichrome, and +4.5% for phosphor bronze, compared to about +188% for a typical copper wire under the same conditions.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-02
... Steel Wire Rod From Brazil: Final Results of the Expedited Second Sunset Review of the Countervailing... of the countervailing duty (CVD) order on carbon and certain alloy steel wire rod (wire rod) from...: Background On June 3, 2013, the Department initiated the second sunset review of the CVD order \\1\\ on wire...
29 CFR 1915.112 - Ropes, chains and slings.
Code of Federal Regulations, 2011 CFR
2011-07-01
... plow steel wire rope and wire rope slings with various types of terminals. For sizes, classifications... than five (5) is maintained. (b) Wire rope and wire rope slings. (1) Tables G-2 through G-5 in § 1915... blunted. (3) Where U-bolt wire rope clips are used to form eyes, Table G-6 in § 1915.118 shall be used to...
29 CFR 1915.112 - Ropes, chains and slings.
Code of Federal Regulations, 2010 CFR
2010-07-01
... plow steel wire rope and wire rope slings with various types of terminals. For sizes, classifications... than five (5) is maintained. (b) Wire rope and wire rope slings. (1) Tables G-2 through G-5 in § 1915... blunted. (3) Where U-bolt wire rope clips are used to form eyes, Table G-6 in § 1915.118 shall be used to...
Dickson, Eamonn J.; Falkenburger, Björn H.
2013-01-01
Gq-coupled plasma membrane receptors activate phospholipase C (PLC), which hydrolyzes membrane phosphatidylinositol 4,5-bisphosphate (PIP2) into the second messengers inositol 1,4,5-trisphosphate (IP3) and diacylglycerol (DAG). This leads to calcium release, protein kinase C (PKC) activation, and sometimes PIP2 depletion. To understand mechanisms governing these diverging signals and to determine which of these signals is responsible for the inhibition of KCNQ2/3 (KV7.2/7.3) potassium channels, we monitored levels of PIP2, IP3, and calcium in single living cells. DAG and PKC are monitored in our companion paper (Falkenburger et al. 2013. J. Gen. Physiol. http://dx.doi.org/10.1085/jgp.201210887). The results extend our previous kinetic model of Gq-coupled receptor signaling to IP3 and calcium. We find that activation of low-abundance endogenous P2Y2 receptors by a saturating concentration of uridine 5′-triphosphate (UTP; 100 µM) leads to calcium release but not to PIP2 depletion. Activation of overexpressed M1 muscarinic receptors by 10 µM Oxo-M leads to a similar calcium release but also depletes PIP2. KCNQ2/3 channels are inhibited by Oxo-M (by 85%), but not by UTP (<1%). These differences can be attributed purely to differences in receptor abundance. Full amplitude calcium responses can be elicited even after PIP2 was partially depleted by overexpressed inducible phosphatidylinositol 5-phosphatases, suggesting that very low amounts of IP3 suffice to elicit a full calcium release. Hence, weak PLC activation can elicit robust calcium signals without net PIP2 depletion or KCNQ2/3 channel inhibition. PMID:23630337
Dickson, Eamonn J; Falkenburger, Björn H; Hille, Bertil
2013-05-01
Gq-coupled plasma membrane receptors activate phospholipase C (PLC), which hydrolyzes membrane phosphatidylinositol 4,5-bisphosphate (PIP2) into the second messengers inositol 1,4,5-trisphosphate (IP3) and diacylglycerol (DAG). This leads to calcium release, protein kinase C (PKC) activation, and sometimes PIP2 depletion. To understand mechanisms governing these diverging signals and to determine which of these signals is responsible for the inhibition of KCNQ2/3 (KV7.2/7.3) potassium channels, we monitored levels of PIP2, IP3, and calcium in single living cells. DAG and PKC are monitored in our companion paper (Falkenburger et al. 2013. J. Gen. Physiol. http://dx.doi.org/10.1085/jgp.201210887). The results extend our previous kinetic model of Gq-coupled receptor signaling to IP3 and calcium. We find that activation of low-abundance endogenous P2Y2 receptors by a saturating concentration of uridine 5'-triphosphate (UTP; 100 µM) leads to calcium release but not to PIP2 depletion. Activation of overexpressed M1 muscarinic receptors by 10 µM Oxo-M leads to a similar calcium release but also depletes PIP2. KCNQ2/3 channels are inhibited by Oxo-M (by 85%), but not by UTP (<1%). These differences can be attributed purely to differences in receptor abundance. Full amplitude calcium responses can be elicited even after PIP2 was partially depleted by overexpressed inducible phosphatidylinositol 5-phosphatases, suggesting that very low amounts of IP3 suffice to elicit a full calcium release. Hence, weak PLC activation can elicit robust calcium signals without net PIP2 depletion or KCNQ2/3 channel inhibition.
Biomedical digital assistant for ubiquitous healthcare.
Lee, Tae-Soo; Hong, Joo-Hyun; Cho, Myeong-Chan
2007-01-01
The concept of ubiquitous healthcare service, which emerged as one of measures to solve healthcare problems in aged society, means that patients can receive services such as prevention, diagnosis, therapy and prognosis management at any time and in any place with the help of advanced information and communication technology. This service requires not only biomedical digital assistant that can monitor continuously the patients' health condition regardless of time and place, but also wired and wireless communication devices and telemedicine servers that provide doctors with data on patients' present health condition. In order to implement a biomedical digital assistant that is portable and wearable to patients, the present study developed a device that minimizes size, weight and power consumption, measures ECG and PPG signals, and even monitors moving patients' state. The biomedical sensor with the function of wireless communication was designed to be highly portable and wearable, to be operable 24 hours with small-size batteries, and to monitor the subject's heart rate, step count and respiratory rate in his daily life. The biomedical signal receiving device was implemented in two forms, PDA and cellular phone. The movement monitoring device embedded in the battery pack of a cellular phone does not have any problem in operating 24 hours, but the real-time biomedical signal receiving device implemented with PDA operated up to 6 hours due to the limited battery capacity of PDA. This problem is expected to be solved by reducing wireless communication load through improving the processing and storage functions of the sensor. The developed device can transmit a message on the patient's emergency to the remote server through the cellular phone network, and is expected to play crucial roles in the health management of chronic-aged patients in their daily life.
3D Encoding of Musical Score Information and the Playback Method Used by the Cellular Phone
NASA Astrophysics Data System (ADS)
Kubo, Hitoshi; Sugiura, Akihiko
Recently, 3G cellular phone that can take a movie has spread by improving the digital camera function. And, 2Dcode has accurate readout and high operability. And it has spread as an information transmission means. However, the symbol is expanded and complicated when information of 2D codes increases. To solve these, 3D code was proposed. But it need the special equipment for readout, and specializes in the enhancing reality feeling technology. Therefore, it is difficult to apply it to the cellular phone. And so, we propose 3D code that can be recognized by the movie shooting function of the cellular phone. And, score information was encoded. We apply Gray Code to the property of music, and encode it. And the effectiveness was verified.
Nwankwo, E O; Ekwunife, N; Mofolorunsho, K C
2014-06-01
Mobile phones of healthcare workers (HCWs) could be colonized by potential bacteria pathogens. The aim of this research is to evaluate the bacterial contamination and antibiotic sensitivity pattern of isolates from mobile phones of HCWs in Grimad hospital. A total of 112 swab samples were collected from the mobile phones of HCWs and students in June 2012 in Anyigba. While 56 samples were from HCWs in Grimad hospital, 56 samples were obtained from non-healthcare workers (NHCWs) who served as the control. The samples were all screened for bacterial pathogens by standard bacteriological procedures. Antibiotic susceptibility testing was done by the disc diffusion technique. The rate of bacterial contamination of mobile phones of HCWs was 94.6%. Bacteria isolated from mobile phones of HCWs were more resistant to antibiotics than NHCWs phones. Staphylococcus Epidermidis (42.9%) was the most frequently isolated bacteria followed by Bacillus spp. (32.1%), Staphylococcus Aureus (25%), Pseudomonas Aeruginosa (19.6%), Escherichia Coli (14.3%), Streptococcus spp. (14.3%), Proteus spp. (12.5%), Klebsiella spp. (7.1%), and Acinetobacter spp. (5.3%). Cotrimoxazole, ampicillin and tetracycline showed high levels of resistance while gentamicin, ciprofloxacin and ceftriaxone exhibited encouraging results. The presence of bacteria pathogens associated with nosocomial infection was identified. Transmission of pathogens can be reduced by hand hygiene and regular cleaning of mobile phones. Copyright © 2013 Ministry of Health, Saudi Arabia. Published by Elsevier Ltd. All rights reserved.
Deformable 3D-2D registration for guiding K-wire placement in pelvic trauma surgery
NASA Astrophysics Data System (ADS)
Goerres, J.; Jacobson, M.; Uneri, A.; de Silva, T.; Ketcha, M.; Reaungamornrat, S.; Vogt, S.; Kleinszig, G.; Wolinsky, J.-P.; Osgood, G.; Siewerdsen, J. H.
2017-03-01
Pelvic Kirschner wire (K-wire) insertion is a challenging surgical task requiring interpretation of complex 3D anatomical shape from 2D projections (fluoroscopy) and delivery of device trajectories within fairly narrow bone corridors in proximity to adjacent nerves and vessels. Over long trajectories ( 10-25 cm), K-wires tend to curve (deform), making conventional rigid navigation inaccurate at the tip location. A system is presented that provides accurate 3D localization and guidance of rigid or deformable surgical devices ("components" - e.g., K-wires) based on 3D-2D registration. The patient is registered to a preoperative CT image by virtually projecting digitally reconstructed radiographs (DRRs) and matching to two or more intraoperative x-ray projections. The K-wire is localized using an analogous procedure matching DRRs of a deformably parametrized model for the device component (deformable known-component registration, or dKC-Reg). A cadaver study was performed in which a K-wire trajectory was delivered in the pelvis. The system demonstrated target registration error (TRE) of 2.1 ± 0.3 mm in location of the K-wire tip (median ± interquartile range, IQR) and 0.8 ± 1.4º in orientation at the tip (median ± IQR), providing functionality analogous to surgical tracking / navigation using imaging systems already in the surgical arsenal without reliance on a surgical tracker. The method offers quantitative 3D guidance using images (e.g., inlet / outlet views) already acquired in the standard of care, potentially extending the advantages of navigation to broader utilization in trauma surgery to improve surgical precision and safety.
Characterization of copper and nichrome wires for safety fuse
NASA Astrophysics Data System (ADS)
Murdani, E.
2016-11-01
Fuse is an important component of an electrical circuit to limiting the current through the electrical circuit for electrical equipment safety. Safety fuses are made of a conductor such as copper and nichrome wires. The aim of this research was to determine the maximum current that can flow in the conductor wires (copper and nichrome). In the experiment used copper and nichrome wires by varying the length of wires (0.2 cm to 20 cm) and diameter of wires (0.1, 0.2, 0.3, 0.4 and 0.5) mm until maximum current reached that marked by melted or broken wire. From this experiment, it will be obtained the dependences data of maximum current to the length and diameter of wires. All data are plotted and it's known as a standard curve. The standard curve will provide an alternative choice of replacing fuse wire according to the maximum current requirement, including the wire type (copper and nichrome wires) and wire dimensions (length and diameter of wire).
2012-09-01
deoxynucleotidyltransferase-mediated dUTP nick-end labeling (TUNEL) as a function of pre & co-treatment with 1) N-acetyl cysteine (NAC) 2) Melatonin & 3) Fluoxetine ... Fluoxetine Group: (n=5 x 4 time points for a total of 20 C57BL/6J mice) 1b. Measurement of cell proliferation in the SVZ, the CC, and the DG at day...1, 14 days, 56 days, and 6 months after 5-FU treatment using Ki-67 as a function of pre & co-treatment with 1) NAC 2) Melatonin & 3) Fluoxetine
2011-09-01
dUTP nick-end labeling (TUNEL) as a function of pre & co-treatment with 1) N-acetyl cysteine (NAC) 2) Melatonin & 3) Fluoxetine . Saline Group...4 time points for a total of 20 C57BL/6J mice) 5-FU + Melatonin Group: (n=5 x 4 time points for a total of 20 C57BL/6J mice) 5-FU + Fluoxetine ...56 days, and 6 months after 5-FU treatment using Ki-67 as a function of pre & co-treatment with 1) NAC 2) Melatonin & 3) Fluoxetine . 1c
Enabling MEMS technologies for communications systems
NASA Astrophysics Data System (ADS)
Lubecke, Victor M.; Barber, Bradley P.; Arney, Susanne
2001-11-01
Modern communications demands have been steadily growing not only in size, but sophistication. Phone calls over copper wires have evolved into high definition video conferencing over optical fibers, and wireless internet browsing. The technology used to meet these demands is under constant pressure to provide increased capacity, speed, and efficiency, all with reduced size and cost. Various MEMS technologies have shown great promise for meeting these challenges by extending the performance of conventional circuitry and introducing radical new systems approaches. A variety of strategic MEMS structures including various cost-effective free-space optics and high-Q RF components are described, along with related practical implementation issues. These components are rapidly becoming essential for enabling the development of progressive new communications systems technologies including all-optical networks, and low cost multi-system wireless terminals and basestations.
NASA Astrophysics Data System (ADS)
Nowakowski, C.; Friedman, D.; Green, P.
2001-10-01
The purpose of the current experiment is to provide a preliminary driving simulator assessment of several hands-free design solutions with regard to the task of answering the phone while driving. Specifically, the following questions were examined: (1) Does the location of a caller ID display and the phone buttons (two HUD (Head Up Display) locations vs. phone cradle) affect either the time to answer the phone or driving performance; (2) Does the presence or absence of a ring affect either the time to answer the phone or driving performance; (3) Does increased driving workload (visual demand) affect either the time to answer the phone or driving performance; (4) What were the initial driver reactions to a HUD-based call timer.
Miller, Christopher W T; Himelhoch, Seth
2013-01-01
Mobile phone technology is increasingly used to overcome traditional barriers limiting access to care. The goal of this study was to evaluate access and willingness to use smart and mobile phone technology for promoting adherence among people attending an urban HIV clinic. One hundred consecutive HIV-positive patients attending an urban HIV outpatient clinic were surveyed. The questionnaire evaluated access to and utilization of mobile phones and willingness to use them to enhance adherence to HIV medication. The survey also included the CASE adherence index as a measure of adherence. The average age was 46.4 (SD = 9.2). The majority of participants were males (63%), black (93%), and Hispanic (11.4%) and reported earning less than $10,000 per year (67.3%). Most identified themselves as being current smokers (57%). The vast majority reported currently taking HAART (83.5%). Approximately half of the participants reported some difficulty with adherence (CASE < 10). Ninety-six percent reported owning a mobile phone. Among owners of mobile phones 47.4% reported currently owning more than one device. Over a quarter reported owning a smartphone. About 60% used their phones for texting and 1/3 used their phone to search the Internet. Nearly 70% reported that they would use a mobile device to help with HIV adherence. Those who reported being very likely or likely to use a mobile device to improve adherence were significantly more likely to use their phone daily (P = 0.03) and use their phone for text messages (P = 0.002). The vast majority of patients in an urban HIV clinic own mobile phones and would use them to enhance adherence interventions to HIV medication.
Estimation of end of life mobile phones generation: The case study of the Czech Republic
DOE Office of Scientific and Technical Information (OSTI.GOV)
Polak, Milos, E-mail: mpolak@remasystem.cz; Drapalova, Lenka
Highlights: Black-Right-Pointing-Pointer In this paper, we define lifespan of mobile phones and estimate their average total lifespan. Black-Right-Pointing-Pointer The estimation of lifespan distribution is based on large sample of EoL mobile phones. Black-Right-Pointing-Pointer Total lifespan of Czech mobile phones is surprisingly long, exactly 7.99 years. Black-Right-Pointing-Pointer In the years 2010-20, about 26.3 million pieces of EoL mobile phones will be generated in the Czech Republic. - Abstract: The volume of waste electrical and electronic equipment (WEEE) has been rapidly growing in recent years. In the European Union (EU), legislation promoting the collection and recycling of WEEE has been in forcemore » since the year 2003. Yet, both current and recently suggested collection targets for WEEE are completely ineffective when it comes to collection and recycling of small WEEE (s-WEEE), with mobile phones as a typical example. Mobile phones are the most sold EEE and at the same time one of appliances with the lowest collection rate. To improve this situation, it is necessary to assess the amount of generated end of life (EoL) mobile phones as precisely as possible. This paper presents a method of assessment of EoL mobile phones generation based on delay model. Within the scope of this paper, the method has been applied on the Czech Republic data. However, this method can be applied also to other EoL appliances in or outside the Czech Republic. Our results show that the average total lifespan of Czech mobile phones is surprisingly long, exactly 7.99 years. We impute long lifespan particularly to a storage time of EoL mobile phones at households, estimated to be 4.35 years. In the years 1990-2000, only 45 thousands of EoL mobile phones were generated in the Czech Republic, while in the years 2000-2010 the number grew to 6.5 million pieces and it is estimated that in the years 2010-2020 about 26.3 million pieces will be generated. Current European legislation sets targets on collection and recycling of WEEE in general, but no specific collection target for EoL mobile phone exists. In the year 2010 only about 3-6% of Czech EoL mobile phones were collected for recovery and recycling. If we make similar estimation using an estimated average EU value, then within the next 10 years about 1.3 billion of EoL mobile phones would be available for recycling in the EU. This amount contains about 31 tonnes of gold and 325 tonnes of silver. Since Europe is dependent on import of many raw materials, efficient recycling of EoL products could help reduce this dependence. To set a working system of collection, it will be necessary to set new and realistic collection targets.« less
Cellular telephone use during free-living walking significantly reduces average walking speed.
Barkley, Jacob E; Lepp, Andrew
2016-03-31
Cellular telephone (cell phone) use decreases walking speed in controlled laboratory experiments and there is an inverse relationship between free-living walking speed and heart failure risk. The purpose of this study was to examine the impact of cell phone use on walking speed in a free-living environment. Subjects (n = 1142) were randomly observed walking on a 50 m University campus walkway. The time it took each subject to walk 50 m was recorded and subjects were coded into categories: cell phone held to the ear (talking, n = 95), holding and looking at the cell phone (texting, n = 118), not visibly using the cell phone (no use, n = 929). Subjects took significantly (p < 0.001) longer traversing the walkway when talking (39.3 s) and texting (37.9 s) versus no use (35.3 s). As was the case with the previous laboratory experiments, cell phone use significantly reduces average speed during free-living walking.
[The long-term fracture resistance of orthodontic nickel-titanium wires].
Drescher, D; Bourauel, C; Sonneborn, W; Schmuth, G P
1994-01-01
This study reports on the long-term fracture resistance of orthodontic nickel titanium wires, a material property that has not been investigated thoroughly, yet. A computer-controlled apparatus was designed to perform long-term bending tests. The investigated material comprised 9 nickel titanium wires (dimensions 0.016", round and 0.016" x 0.022", rectangular) as well as a stainless steel and a beta-titanium wire that were included as reference. Compared with the steel wire, the nickel titanium wires exhibited 2- to 5-fold higher yield forces in bending. At a specified deflection angle, the generated bending forces of the nickel titanium wires reached one half to one fourth of the values of steel. The fracture resistance under longterm loading was determined using the Wöhler-method. After 10(5) loadings, 0.016" nickel titanium wires were subject to break failure, if forces exceed values greater than 1.2 to 3.1 N. Steel and TMA wires could be loaded with forces of up to 4.4 and 3.7 N, respectively. The 0.016" x 0.022"-rectangular wires allowed forces of approximately twice this magnitude. Elastic fatigue of the superelastic specimens "Memorywire", "Rematitan Lite", and "Sentalloy medium" showed up as hardening of the wire by up to 70%. Material degradation lead to a severe deformation of the hysteresis loop and to plastic deformation. Work-hardened martensitic NiTi wires did not show these effects to this extent.
Ross, Kathryn M; Wing, Rena R
2016-08-01
Despite the proliferation of newer self-monitoring technology (e.g., activity monitors and smartphone apps), their impact on weight loss outside of structured in-person behavioral intervention is unknown. A randomized, controlled pilot study was conducted to examine efficacy of self-monitoring technology, with and without phone-based intervention, on 6-month weight loss in adults with overweight and obesity. Eighty participants were randomized to receive standard self-monitoring tools (ST, n = 26), technology-based self-monitoring tools (TECH, n = 27), or technology-based tools combined with phone-based intervention (TECH + PHONE, n = 27). All participants attended one introductory weight loss session and completed assessments at baseline, 3 months, and 6 months. Weight loss from baseline to 6 months differed significantly between groups P = 0.042; there was a trend for TECH + PHONE (-6.4 ± 1.2 kg) to lose more weight than ST (-1.3 ± 1.2 kg); weight loss in TECH (-4.1 ± 1.4 kg) was between ST and TECH + PHONE. Fewer ST (15%) achieved ≥5% weight losses compared with TECH and TECH + PHONE (44%), P = 0.039. Adherence to self-monitoring caloric intake was higher in TECH + PHONE than TECH or ST, Ps < 0.05. These results suggest use of newer self-monitoring technology plus brief phone-based intervention improves adherence and weight loss compared with traditional self-monitoring tools. Further research should determine cost-effectiveness of adding phone-based intervention when providing self-monitoring technology. © 2016 The Obesity Society.
Hardell, Lennart; Carlberg, Michael; Hansson Mild, Kjell
2011-05-01
We studied the association between use of mobile and cordless phones and malignant brain tumours. Pooled analysis was performed of two case-control studies on patients with malignant brain tumours diagnosed during 1997-2003 and matched controls alive at the time of study inclusion and one case-control study on deceased patients and controls diagnosed during the same time period. Cases and controls or relatives to deceased subjects were interviewed using a structured questionnaire. Replies were obtained for 1,251 (85%) cases and 2,438 (84%) controls. The risk increased with latency period and cumulative use in hours for both mobile and cordless phones. Highest risk was found for the most common type of glioma, astrocytoma, yielding in the >10 year latency group for mobile phone use odds ratio (OR) = 2.7, 95% confidence interval (CI) = 1.9-3.7 and cordless phone use OR = 1.8, 95% CI = 1.2-2.9. In a separate analysis, these phone types were independent risk factors for glioma. The risk for astrocytoma was highest in the group with first use of a wireless phone before the age of 20; mobile phone use OR = 4.9, 95% CI = 2.2-11, cordless phone use OR = 3.9, 95% CI = 1.7-8.7. In conclusion, an increased risk was found for glioma and use of mobile or cordless phone. The risk increased with latency time and cumulative use in hours and was highest in subjects with first use before the age of 20.
Ross, Kathryn M.; Wing, Rena R.
2016-01-01
Objective Despite the proliferation of newer self-monitoring technology (e.g., activity monitors and smartphone apps), their impact on weight loss outside of structured in-person behavioral intervention is unknown. Methods A randomized, controlled pilot study was conducted to examine efficacy of self-monitoring technology, with and without phone-based intervention, on 6-month weight loss in adults with overweight and obesity. Eighty participants were randomized to receive standard self-monitoring tools (ST, n=26), technology-based self-monitoring tools (TECH, n=27), or technology-based tools combined with phone-based intervention (TECH+PHONE, n=27). All participants attended one introductory weight loss session and completed assessments at baseline, 3 months, and 6 months. Results Weight loss from baseline to 6 months differed significantly between groups p=.042; there was a trend for TECH+PHONE (−6.4±1.2kg) to lose more weight than ST (−1.3±1.2kg); weight loss in TECH (−4.1±1.4kg) was between ST and TECH+PHONE. Fewer ST (15%) achieved ≥5% weight losses compared to TECH and TECH+PHONE (44%), p=.039. Adherence to self-monitoring caloric intake was higher in TECH+PHONE than TECH or ST, ps<.05. Conclusion These results suggest use of newer self-monitoring technology plus brief phone-based intervention improves adherence and weight loss compared to traditional self-monitoring tools. Further research should determine cost-effectiveness of adding phone-based intervention when providing self-monitoring technology. PMID:27367614
Babu, K Pradeep; Keerthi, V Naga; Madathody, Deepika; Prasanna, A Laxmi; Gopinath, Vidhya; Kumar, M Senthil; Kumar, A Nanda
2016-05-01
Recent metallurgical research and advancement in material science has benefited orthodontists in the selection of an appropriate wire size and alloy type, which is necessary to provide an optimum and predictable treatment results. The purpose of the study was to clinically evaluate and compare the surface characteristics of 16 x 22 stainless steel, Titanium molybdenum alloy, timolium, and titanium-niobium before and after placing them in a patient's mouth for 3 months using a scanning electron microscope (SEM). The total sample size was 40, which were divided into four groups (group 1 - stainless steel wires, 10 samples, group 2 - TMA wires, 10 samples, group 3 - timolium wires, 10 samples, and group 4 - titanium-niobium wires, 10 samples), and these were further subdivided into 5 each. The first subgroup of five samples was placed in the patient's mouth and was evaluated under SEM, and another subgroup of five samples was directly subjected to the SEM. Scanning electron microscopic evaluation of surface characteristics of unused 16 x 22 rectangular stainless steel wire under 500 x magnification showed an overall smooth surface. Stainless steel wire samples placed in the patient's mouth showed black hazy patches, which may be interoperated as areas of stress. TMA unused wires showed multiple small voids of areas and small craters with fewer elevated regions. The TMA wire samples placed in the patient's mouth showed black hazy patches and prominent ridges, making the wire rougher. Timolium unused archwires showed heavy roughness and voids, whereas wires tested in the patient's mouth showed homogeneous distribution of deep cracks and craters. Unused titanium-niobium archwires showed uniform prominent striations and ridges with occasional voids, whereas wires used in the patient's mouth showed prominent huge voids that could be interpreted as maximum stress areas. Stainless steel (group 1) used and unused wires showed smooth surface characteristics when compared with all the other three groups followed by timolium, which was superior to titanium-niobium wires and TMA wires. Timolium wires are superior to titanium-niobium wires and TMA wires.
NASA Astrophysics Data System (ADS)
Hewes, Alaïs; Mydlarski, Laurent
2015-11-01
The present work focuses on the design and optimization of a probe used to simultaneously measure the velocity, concentration and temperature fields in a turbulent jet. The underlying principles of this sensor are based in thermal-anemometry techniques, and the design of this 3-wire probe builds off the previous work of Sirivat and Warhaft, J. Fluid Mech., 1982. In the first part of this study, the effect of different overheat ratios in the first two wires (called the ``interference'' or ``Way-Libby'' probe - used to infer velocity and concentration) are investigated. Of particular interest is their effect on the quality of the resulting calibration, as well as the measured velocity and concentration data. Four different overheat ratio pairs for the two wires comprising the interference probe are studied. In the second part of this work, a third wire, capable of detecting temperature fluctuations, is added to the 3-wire probe. The optimal configuration of this probe, including wire type and overheat ratio for the third wire, is studied and the simultaneously-measured velocity, concentration, and temperature data (e.g. spectra, PDFs) for different probe configurations are presented. Supported by the Natural Sciences and Engineering Research Council of Canada (Grant 217184).
Multiwire thermocouples: Frequency response
NASA Technical Reports Server (NTRS)
Forney, L. J.; Fralick, G. C.
1994-01-01
Experimental measurements are made with a novel two wire thermocouple. Signals from two wires of unequal diameters are recorded from the thermocouple suspended in constant flow with a periodic temperature fluctuation. It is demonstrated that the reconstructed signal from the two wire thermocouple requires no compensation for omega less than or equal to 2 omega(sub 1) where omega is the natural frequency of the smaller wire. A compensation factor is recommended for larger frequencies omega greater than 2 omega(sub 1). Theory and experimental measurements are compared with a novel three wire thermocouple. Signals from three wires of unequal diameters are recorded from the thermocouple suspended in constant flow with a periodic temperature fluctuation. It is demonstrated that the reconstructed signal from the three wire thermocouple requires no compensation for omega less than or equal to 5 omega(sub 1) where omega (sub 1) is the natural frequency of the smaller wire. The latter result represents a significant improvement compared to previous work with two wire thermocouples. A correction factor has also been derived to account for wires of arbitrary diameter. Measurements are recorded for multiwire thermocouples consisting of either two or three wires of unequal diameters. Signals from the multiwire probe are recorded for a reversing gas flow with a periodic temperature fluctuation. It is demonstrated that the reconstructed signal from the multiwire thermocouple requires no compensation provided omega/omega(sub 1) is less than 2.3 for two wires or omega/omega(sub 1) is less than 3.6 for three wires where omega(sub 1) is the natural frequency of the smaller wire based on the maximum gas velocity. The latter results were possible provided Fourier transformed data were used and knowledge of the gas velocity is available.
40 CFR 63.3890 - What emission limits must I meet?
Code of Federal Regulations, 2010 CFR
2010-07-01
... compliance period. (3) For each new magnet wire coating affected source, limit organic HAP emissions to no...) coating solids used during each 12-month compliance period. (3) For each existing magnet wire coating.... (1) If the general use or magnet wire surface coating operations subject to only one of the emission...
Greening academia: use and disposal of mobile phones among university students.
Ongondo, F O; Williams, I D
2011-07-01
Mobile phones have relatively short lifecycles and are rapidly seen as obsolete by many users within little over a year. However, the reusability of these devices as well as their material composition means that in terms of mass and volume, mobile phones represent the most valuable electronic products that are currently found in large numbers in waste streams. End-of-life mobile phones are a high value (from a reuse and resource perspective), high volume (quantity), low cost (residual monetary value) and transient (short lifecycle) electronic product. There are very large numbers of higher education (mainly university) students in the world--there are>2.4 million in the UK alone, 19 million in Europe and 18.2 million in the USA--and they often replace their mobile phones several times before graduation. Thus, because of the potentially significant environmental and economic impacts, a large scale survey of students at 5 UK universities was conducted to assess the behaviour of students with regard to their use and disposal of mobile phones. Additionally, a small scale trial mobile phone takeback service at one of the universities was carried out. The findings indicate that many students replace their phones at least once a year; replacing broken phones, getting upgrades from network operators, remaining "fashionable" and a desire to have a handset with a longer battery life are the main reasons for such rapid replacement. Almost 60% of replaced phones are not sent to reuse or recycling operations but are stockpiled by students mainly as spare/backup phones. Approximately 61% of students own an extra mobile phone with male students replacing their phones more often than females. In particular, the results highlight the potentially huge stockpile of mobile phones--and consequently valuable supplies of rare metals--being held by the public; we estimate that there are 3.7 million phones stockpiled by students in UK higher education alone (29.3 and 28.1 million stockpiled, respectively, for Europe and USA). Although many students are aware of UK mobile phone takeback services, only a moderate number have previously used the services. Students' recycling of other waste materials such as paper and glass did not have a significant impact on their disposal actions for their unwanted mobile phones, although students who often recycled these waste materials were also the most willing to participate in mobile phone takeback services. Monetary incentives such as cash payments and vouchers have the greatest influence over students' willingness to utilise takeback services, followed by convenience and ease of use of the services. The paper discusses these findings as well as the outcome of the trial mobile phone takeback. It is suggested that universities should partner with established takeback operators to conduct event-based mobile phone takeback services primarily targeting students. Lessons from mobile phone takeback applicable to takeback services for end-of-life gadgets similar to mobile phones are also discussed. Copyright © 2011 Elsevier Ltd. All rights reserved.
Al-Hendy, Ayman; Lee, Eun J; Wang, Hui Q; Copland, John A
2004-11-01
Leiomyomas (fibroids) are common estrogen-dependent uterine tumors with no effective medicinal treatment; hysterectomy is the mainstay of management. This study was undertaken to investigate a potential therapy for leiomyoma; we used a mutated dominant-negative estrogen receptor gene delivered via an adenoviral vector (Ad-ER-DN). Ad-ER-DN transduction, in both human and rat leiomyoma cell lines, induced an increase in both caspase-3 levels and BAX/Bcl-2 ratio with evident apoptosis in the TdT-mediated dUTP nick-end labeling assay. In nude mice, rat leiomyoma cells ex vivo transduced with Ad-ER-DN supported significantly smaller tumors compared with Ad-LacZ-treated cells 5 weeks after implantation. In mice treated by direct intratumor injection into preexisting lesions, Ad-ER-DN caused immediate overall arrest of tumor growth. The Ad-ER-DN-treated tumors demonstrated severely inhibited cell proliferation (BrdU index) and a marked increase in the number of apoptotic cells (TdT-mediated dUTP nick-end labeling index). Dominant-negative estrogen receptor gene therapy may provide a nonsurgical treatment option for women with symptomatic uterine fibroids who want to preserve their uteri.
Optimization benefits analysis in production process of fabrication components
NASA Astrophysics Data System (ADS)
Prasetyani, R.; Rafsanjani, A. Y.; Rimantho, D.
2017-12-01
The determination of an optimal number of product combinations is important. The main problem at part and service department in PT. United Tractors Pandu Engineering (shortened to PT.UTPE) Is the optimization of the combination of fabrication component products (known as Liner Plate) which influence to the profit that will be obtained by the company. Liner Plate is a fabrication component that serves as a protector of core structure for heavy duty attachment, such as HD Vessel, HD Bucket, HD Shovel, and HD Blade. The graph of liner plate sales from January to December 2016 has fluctuated and there is no direct conclusion about the optimization of production of such fabrication components. The optimal product combination can be achieved by calculating and plotting the amount of production output and input appropriately. The method that used in this study is linear programming methods with primal, dual, and sensitivity analysis using QM software for Windows to obtain optimal fabrication components. In the optimal combination of components, PT. UTPE provide the profit increase of Rp. 105,285,000.00 for a total of Rp. 3,046,525,000.00 per month and the production of a total combination of 71 units per unit variance per month.
Wang, Chun-Hua; Chou, Pai-Chien; Joa, Wen-Ching; Chen, Li-Fei; Sheng, Te-Fang; Ho, Shu-Chuan; Lin, Horng-Chyuan; Huang, Chien-Da; Chung, Fu-Tsai; Chung, Kian Fan; Kuo, Han-Pin
2014-08-30
Moderate-intensity exercise training improves skeletal muscle aerobic capacity and increased oxidative enzyme activity, as well as exercise tolerance in COPD patients. To investigate whether the home-based exercise training program can reduce inflammatory biomarkers in patients with COPD, twelve patients using mobile phone assistance and 14 with free walk were assessed by incremental shuttle walk test (ISWT), spirometry, strength of limb muscles, and serum C-reactive protein (CRP) and inflammatory cytokines. Patients in the mobile phone group improved their ISWT walking distance, with decrease in serum CRP after 2 months, and sustained at 6 months. Patients in the control group had no improvement. Serum IL-8 in the mobile phone group was significantly reduced at 2, 3 and 6 months after doing home exercise training compared to baseline. IL-6 and TNF-α were significantly elevated at 3 and 6 months in control group, while there were no changes in mobile phone group. The strength of limb muscles was significantly greater compared to baseline at 3 and 6 months in the mobile phone group. A mobile-phone-based system can provide an efficient home endurance exercise training program with improved exercise capacity, strength of limb muscles and a decrease in serum CRP and IL-8 in COPD patients. Decreased systemic inflammation may contribute to these clinical benefits. (Clinical trial registration No.: NCT01631019).
NASA Technical Reports Server (NTRS)
Lundquist, Ray A.; Leidecker, Henning
1998-01-01
The allowable operating currents of electrical wiring when used in the space vacuum environment is predominantly determined by the maximum operating temperature of the wire insulation. For Kapton insulated wire this value is 200 C. Guidelines provided in the Goddard Space Flight Center (GSFC) Preferred Parts List (PPL) limit the operating current of wire within vacuum to ensure the maximum insulation temperature is not exceeded. For 20 AWG wire, these operating parameters are: 3.7 amps per wire, bundle of 15 or more wires, 70 C environment, and vacuum of 10(exp -5) torr or less. To determine the behavior and temperature of electrical wire at different operating conditions, a thermal vacuum test was performed on a representative electrical harness of the Hubble Space Telescope (HST) power distribution system. This paper describes the test and the results.
Ma, Mingming; Xu, Yupeng; Xiong, Shuyu; Zhang, Jian; Gu, Qing; Ke, Bilian; Xu, Xun
2018-05-23
Ciliary neurotrophic factor (CNTF) has been evaluated as a candidate therapeutic agent for diabetes and its neural complications. However, its role in diabetic retinopathy has not been fully elucidated. This is a randomized unblinded animal experiment. Wistar rats with streptozocin (STZ)-induced diabetes were regularly injected with CNTF or vehicle control in their vitreous bodies beginning at 2 weeks after STZ injection. A total of five injections were used. In diabetic rats, the levels of CNTF and neurotrophin-3 (NT-3) were evaluated by enzyme-linked immunosorbent assays (ELISA) and real-time PCR. The abundance of tyrosine hydroxylase (TH) and β-III tubulin was detected by western blot. Transferase-mediated dUTP nick-end labeling staining (TUNEL) was used to detect cell apoptosis in the retinal tissue. The activation of caspase-3 was also measured. The protein and mRNA levels of CNTF in diabetic rat retinas were reduced compared to control rats. In addition, retinal ganglion cells (RGCs) and dopaminergic amacrine cells appeared to undergo degeneration in diabetic rat retinas, as revealed by transferase-mediated dUTP nick-end labeling staining (TUNEL). Tyrosine hydroxylase (TH) and β-III tubulin protein levels also decreased significantly. Intraocular administration of CNTF rescued RGCs and dopaminergic amacrine cells from neurodegeneration and counteracted the downregulation of β-III tubulin and TH expression, thus demonstrating its therapeutic potential. Our study suggests that early diabetic retinal neuropathy involves the reduced expression of CNTF and can be ameliorated by an exogenous supply of this neurotrophin.
PCACE- PERSONAL COMPUTER AIDED CABLING ENGINEERING
NASA Technical Reports Server (NTRS)
Billitti, J. W.
1994-01-01
A computerized interactive harness engineering program has been developed to provide an inexpensive, interactive system which is designed for learning and using an engineering approach to interconnection systems. PCACE is basically a database system that stores information as files of individual connectors and handles wiring information in circuit groups stored as records. This directly emulates the typical manual engineering methods of data handling, thus making the user interface to the program very natural. Data files can be created, viewed, manipulated, or printed in real time. The printed ouput is in a form ready for use by fabrication and engineering personnel. PCACE also contains a wide variety of error-checking routines including connector contact checks during hardcopy generation. The user may edit existing harness data files or create new files. In creating a new file, the user is given the opportunity to insert all the connector and harness boiler plate data which would be part of a normal connector wiring diagram. This data includes the following: 1) connector reference designator, 2) connector part number, 3) backshell part number, 4) cable reference designator, 5) cable part number, 6) drawing revision, 7) relevant notes, 8) standard wire gauge, and 9) maximum circuit count. Any item except the maximum circuit count may be left blank, and any item may be changed at a later time. Once a file is created and organized, the user is directed to the main menu and has access to the file boiler plate, the circuit wiring records, and the wiring records index list. The organization of a file is such that record zero contains the connector/cable boiler plate, and all other records contain circuit wiring data. Each wiring record will handle a circuit with as many as nine wires in the interface. The record stores the circuit name and wire count and the following data for each wire: 1) wire identifier, 2) contact, 3) splice, 4) wire gauge if different from standard, 5) wire/group type, 6) wire destination, and 7) note number. The PCACE record structure allows for a wide variety of wiring forms using splices and shields, yet retains sufficient structure to maintain ease of use. PCACE is written in TURBO Pascal 3.0 and has been implemented on IBM PC, XT, and AT systems under DOS 3.1 with a memory of 512K of 8 bit bytes, two floppy disk drives, an RGB monitor, and a printer with ASCII control characters. PCACE was originally developed in 1983, and the IBM version was released in 1986.
Lee, Young-Kyun; Koo, Kyung-Hoi
2017-01-01
Purpose Bipolar hemiarthroplasty (HA) is an option for the treatment of unstable intertrochanteric fracture in elderly patients. There is a raising concern regarding cable-grip related complications for the fixation of trochanteric fragments. Therefore, the aim of this study was to evaluate outcome of cementless HA with fixation for the trochanteric fragments using monofilament wires in unstable intertrochanteric fracture. Materials and Methods We reviewed 92 cementless bipolar HAs using a grit-blasted long stem design for unstable intertrochanteric fractures in 91 elderly patients with a mean age of 81.7 years. During the arthroplasty, trochanteric fracture fragments were fixed using 1 or 2 vertical wires and transverse wires. We evaluated the clinical outcomes such as abductor power, ambulatory ability and wire-related complications, and radiologic outcomes including the union of the trochanteric fragment and subsidence of stem. Results Sixty-two patients were followed for a minimum of 2 years (mean, 59 months) postoperatively. The mean abductor power and Koval category was 4.1 (range, 3 to 5) and 4.6 (range, 1 to 6). The wire was broken in 3 hips (4.8%) and the nonunion of the greater trochanter occurred in 1 hips (1.6%). Two stems subsided by 3 mm and 8 mm, respectively, during postoperative 6 weeks, after which the subsidence was not progressive. Conclusion Cerclage wiring of the trochanter using monofilament wire leads to acceptable outcome in cementless HA for senile patients with unstable intertrochanteric fracture. Cerclage wiring using a monofilament wire is recommended for the fixation of trochanteric fragments. PMID:29250501
47 CFR 64.710 - Operator services for prison inmate phones.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 3 2010-10-01 2010-10-01 false Operator services for prison inmate phones. 64.710 Section 64.710 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER... services for prison inmate phones. (a) Each provider of inmate operator services shall: (1) Identify itself...
Tele-EnREDando.com: A Multimedia WEB-CALL Software for Mobile Phones.
ERIC Educational Resources Information Center
Garcia, Jose Carlos
2002-01-01
Presents one of the world's first prototypes of language learning software for smart-phones. Tele-EnREDando.com is an Internet based multimedia application designed for 3G mobile phones with audio, video, and interactive exercises for learning Spanish for business. (Author/VWL)
Lim, Eugene Y; Lee, Chiang; Cai, Weidong; Feng, Dagan; Fulham, Michael
2007-01-01
Medical practice is characterized by a high degree of heterogeneity in collaborative and cooperative patient care. Fast and effective communication between medical practitioners can improve patient care. In medical imaging, the fast delivery of medical reports to referring medical practitioners is a major component of cooperative patient care. Recently, mobile phones have been actively deployed in telemedicine applications. The mobile phone is an ideal medium to achieve faster delivery of reports to the referring medical practitioners. In this study, we developed an electronic medical report delivery system from a medical imaging department to the mobile phones of the referring doctors. The system extracts a text summary of medical report and a screen capture of diagnostic medical image in JPEG format, which are transmitted to 3G GSM mobile phones.
Cell Phones to Collect Pregnancy Data From Remote Areas in Liberia
Lori, Jody R.; Munro, Michelle L.; Boyd, Carol J.; Andreatta, Pamela
2012-01-01
Purpose To report findings on knowledge and skill acquisition following a 3-day training session in the use of short message service (SMS) texting with non- and low-literacy traditional midwives. Design A pre- and post-test study design was used to assess knowledge and skills acquisition with 99 traditional midwives on the use of SMS texting for real-time, remote data collection in rural Liberia, West Africa. Methods Paired sample t-tests were conducted to establish if overall mean scores varied significantly from pre-test to immediate post-test. Analysis of variance was used to compare means across groups. The nonparametric McNemar’s test was used to determine significant differences between the pre-test and post-test values of each individual step involved in SMS texting. Pearson’s chi-square test of independence was used to examine the association between ownership of cell phones within a family and achievement of the seven tasks. Findings The mean increase in cell phone knowledge scores was 3.67, with a 95% confidence interval ranging from 3.39 to 3.95. Participants with a cell phone in the family did significantly better on three of the seven tasks in the pre-test: “turns cell on without help” (χ2(1) = 9.15, p = .003); “identifies cell phone coverage” (χ2(1) = 5.37, p = .024); and “identifies cell phone is charged” (χ2(1) = 4.40, p = .042). Conclusions A 3-day cell phone training session with low- and nonliterate traditional midwives in rural Liberia improved their ability to use mobile technology for SMS texting. Clinical Relevance Mobile technology can improve data collection accessibility and be used for numerous healthcare and public health issues. Cell phone accessibility holds great promise for collecting health data in low-resource areas of the world. PMID:22672157
Stainless-steel wires exclude gulls from a wastewater treatment plant
Clark, Daniel E.; Koenen, Kiana K. G.; MacKenzie, Kenneth G.; Pereira, Jillian W.; DeStefano, Stephen
2013-01-01
There is growing concern about the prevalence of pathogens and antibiotic-resistant bacteria in the environment and the role wildlife plays in their transmission and dissemination. Gulls feeding at wastewater treatment plants may provide a route for transmission of pathogens and bacteria to public water supplies or other critical areas. The authors identified gulls routinely feeding at a wastewater treatment plant in Millbury, Mass., and tested the effectiveness of overhead stainless-steel wires in excluding gulls from the plant. The number of gulls in certainstructures was compared before and after wiring and during an experimental approach using simultaneous treatments and controls. Stainless-steel wires spaced at 0.9-3.3 m (3-10 ft) effectively prevented gulls from using treatment structures (p < 0.0001) and were effective for > 24 months. Materials costs to wire all structures was about $5,700, and labor costs were $4,020. Overhead stainless-steel wires can provide a long-term, cost-efficient method of excluding ring-billed gulls from wastewater treatment plants.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-10
... DEPARTMENT OF COMMERCE International Trade Administration [C-552-813] Steel Wire Garment Hangers... respect to imports of steel wire garment hangers from the Socialist Republic of Vietnam (Vietnam) with the... Department of Commerce building. \\3\\ See Steel Wire Garment Hangers From the Socialist Republic of Vietnam...
Al-Khlaiwi, Thamir; Meo, Sultan A
2004-06-01
The widespread use of mobile phones has been increased over the past decade; they are now an essential part of business, commerce and society. The use of mobile phones can cause health problems. Therefore, the aim of the present study is to investigate the association of using mobile phones with fatigue, headache, dizziness, tension and sleep disturbance in the Saudi population and provide health and social awareness in using these devices. This study was conducted in the Department of Physiology, College of Medicine, King Saud University, Riyadh, Kingdom of Saudi Arabia during the year 2002 to 2003. In the present study, a total of 437 subjects (55.1% male and 39.9% female) were invited, they have and had been using mobile phones. A questionnaire was distributed regarding detailed history and association of mobile phones with health hazards. The results of the present study showed an association between the use of mobile phones and health hazards. The overall mean percentage for these clinical findings in all groups were headache (21.6%), sleep disturbance (4.%), tension (3.9%), fatigue (3%) and dizziness (2.4%). Based on the results of the present study, we conclude that the use of mobile phones is a risk factor for health hazards and suggest that long term or excessive use of mobile phones should be avoided by health promotion activities such as group discussions, public presentations and through electronic and print media sources.
Radiation from mobile phone systems: Is it perceived as a threat to people's health?
Kristiansen, Ivar S; Elstein, Arthur S; Gyrd-Hansen, Dorte; Kildemoes, Helle W; Nielsen, Jesper B
2009-07-01
The aim of this study was to explore the prevalence, nature and determinants of concerns about mobile phone radiation. We used data from a 2006 telephone survey of 1004 people aged 15+ years in Denmark. Twenty-eight percent of the respondents were concerned about exposure to mobile phone radiation; radiation from masts was of concern to about 15%. In contrast, 82% were concerned about pollution. Nearly half of the respondents considered the mortality risk of 3G phones and masts to be of the same order of magnitude as being struck by lightning (0.1 fatalities per million people per year) while 7% thought it was equivalent to tobacco-induced lung cancer (approximately 500 fatalities per million per year). Among women, concerns about mobile phone radiation were positively associated with educational attainment, perceived mobile phone mortality risk and concerns about unknown consequences of new technologies. More than two thirds of the respondents felt that they had received inadequate public information about the 3G system. The results of the study indicate that the majority of the population has little concern about mobile phone radiation while a small minority is very concerned. (c) 2009 Wiley-Liss, Inc.
Matras, M. R.; Jiang, J.; Larbalestier, D. C.; Hellstrom, E. E.
2016-01-01
Overpressure (OP) processing increases the critical current density (JC) of Bi2Sr2CaCu2Ox (2212) round wires by shrinking the surrounding Ag matrix around the 2212 filaments, driving them close to full density and greatly increasing the 2212 grain connectivity. Indeed densification is vital for attaining the highest JC. Here, we investigate the time and temperature dependence of the wire densification. We find that the wire diameter decreases by 3.8 ± 0.3 % after full heat treatment at 50 atm and 100 atm OP. At 50 atm OP pressure, the filaments start densifying above 700 °C and reach a 3.30 ± 0.07 % smaller diameter after 2 h at 820 °C, which is below the melting point of 2212 powder. The densification is homogeneous and does not change the filament shape before melting. The growth of non-superconducting phases is observed at 820 °C, suggesting that time should be minimized at high temperature prior to melting the 2212 powder. Study of an open-ended 2.2 m long wire sample shows that full densification and the high OP JC (JC varies by about 3.1 times over the 2.2 m long wire) is reached about 1 m from the open ends, thus showing that coil-length wires can be protected from leaky seals by adding at least 1 m of sacrificial wire at each end. PMID:28479675
Crystallization and preliminary X-ray studies of dUTPase from Mason–Pfizer monkey retrovirus
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barabás, Orsolya; Németh, Veronika; Vértessy, Beáta G., E-mail: vertessy@enzim.hu
2006-04-01
Deoxyuridine 5′-triphosphate nucleotidohydrolase from Mason–Pfizer monkey retrovirus (M-PMV dUTPase) is a betaretroviral member of the dUTPase enzyme family. The nucleocapsid-free dUTPase (48426 Da) was co-crystallized with a dUTP substrate analogue using the hanging-drop vapour-diffusion method. Deoxyuridine 5′-triphosphate nucleotidohydrolase from Mason–Pfizer monkey retrovirus (M-PMV dUTPase) is a betaretroviral member of the dUTPase enzyme family. In the mature M-PMV virion, this enzyme is present as the C-terminal domain of the fusion protein nucleocapsid-dUTPase. The homotrimeric organization characteristic of dUTPases is retained in this bifunctional fusion protein. The fusion protein supposedly plays a role in adequate localization of dUTPase activity in the vicinitymore » of nucleic acids during reverse transcription and integration. Here, the nucleocapsid-free dUTPase (48 426 Da) was cocrystallized with a dUTP substrate analogue using the hanging-drop vapour-diffusion method. The obtained crystals belong to the primitive hexagonal space group P6{sub 3}, with unit-cell parameters a = 60.6, b = 60.6, c = 63.6 Å, α = 90, β = 90, γ = 120°. Native and PtCl{sub 4}-derivative data sets were collected using synchrotron radiation to 1.75 and 2.3 Å, respectively. Phasing was successfully performed by isomorphous replacement combined with anomalous scattering.« less
Chernenkov, Iu V; Gumeniuk, O I
2009-01-01
The paper presents the results of studying the impact of using cellular phones and personal computers on the health status of 277 Saratov schoolchildren (mean age 13.2 +/- 2.3 years). About 80% of the adolescents have been ascertained to use cellular phones and computers mainly for game purposes. The active users of cellular phones and computers show a high aggressiveness, anxiety, hostility, and social stress, low stress resistance, and susceptibility to arterial hypotension. The negative influence of cellular phones and computers on the schoolchildren's health increases with the increased duration and frequency of their use.
Hardell, Lennart; Carlberg, Michael; Söderqvist, Fredrik; Mild, Kjell Hansson
2013-10-01
We previously conducted a case-control study of acoustic neuroma. Subjects of both genders aged 20-80 years, diagnosed during 1997-2003 in parts of Sweden, were included, and the results were published. We have since made a further study for the time period 2007-2009 including both men and women aged 18-75 years selected from throughout the country. These new results for acoustic neuroma have not been published to date. Similar methods were used for both study periods. In each, one population-based control, matched on gender and age (within five years), was identified from the Swedish Population Registry. Exposures were assessed by a self-administered questionnaire supplemented by a phone interview. Since the number of acoustic neuroma cases in the new study was low we now present pooled results from both study periods based on 316 participating cases and 3,530 controls. Unconditional logistic regression analysis was performed, adjusting for age, gender, year of diagnosis and socio-economic index (SEI). Use of mobile phones of the analogue type gave odds ratio (OR) = 2.9, 95% confidence interval (CI) = 2.0-4.3, increasing with >20 years latency (time since first exposure) to OR = 7.7, 95% CI = 2.8-21. Digital 2G mobile phone use gave OR = 1.5, 95% CI = 1.1-2.1, increasing with latency >15 years to an OR = 1.8, 95% CI = 0.8-4.2. The results for cordless phone use were OR = 1.5, 95% CI = 1.1-2.1, and, for latency of >20 years, OR = 6.5, 95% CI = 1.7-26. Digital type wireless phones (2G and 3G mobile phones and cordless phones) gave OR = 1.5, 95% CI = 1.1-2.0 increasing to OR = 8.1, 95% CI = 2.0-32 with latency >20 years. For total wireless phone use, the highest risk was calculated for the longest latency time >20 years: OR = 4.4, 95% CI = 2.2-9.0. Several of the calculations in the long latency category were based on low numbers of exposed cases. Ipsilateral use resulted in a higher risk than contralateral for both mobile and cordless phones. OR increased per 100 h cumulative use and per year of latency for mobile phones and cordless phones, though the increase was not statistically significant for cordless phones. The percentage tumour volume increased per year of latency and per 100 h of cumulative use, statistically significant for analogue phones. This study confirmed previous results demonstrating an association between mobile and cordless phone use and acoustic neuroma.
HARDELL, LENNART; CARLBERG, MICHAEL; SÖDERQVIST, FREDRIK; MILD, KJELL HANSSON
We previously conducted a case-control study of acoustic neuroma. Subjects of both genders aged 20–80 years, diagnosed during 1997–2003 in parts of Sweden, were included, and the results were published. We have since made a further study for the time period 2007–2009 including both men and women aged 18–75 years selected from throughout the country. These new results for acoustic neuroma have not been published to date. Similar methods were used for both study periods. In each, one population-based control, matched on gender and age (within five years), was identified from the Swedish Population Registry. Exposures were assessed by a self-administered questionnaire supplemented by a phone interview. Since the number of acoustic neuroma cases in the new study was low we now present pooled results from both study periods based on 316 participating cases and 3,530 controls. Unconditional logistic regression analysis was performed, adjusting for age, gender, year of diagnosis and socio-economic index (SEI). Use of mobile phones of the analogue type gave odds ratio (OR) = 2.9, 95% confidence interval (CI) = 2.0–4.3, increasing with >20 years latency (time since first exposure) to OR = 7.7, 95% CI = 2.8–21. Digital 2G mobile phone use gave OR = 1.5, 95% CI = 1.1–2.1, increasing with latency >15 years to an OR = 1.8, 95% CI = 0.8–4.2. The results for cordless phone use were OR = 1.5, 95% CI = 1.1–2.1, and, for latency of >20 years, OR = 6.5, 95% CI = 1.7–26. Digital type wireless phones (2G and 3G mobile phones and cordless phones) gave OR = 1.5, 95% CI = 1.1–2.0 increasing to OR = 8.1, 95% CI = 2.0–32 with latency >20 years. For total wireless phone use, the highest risk was calculated for the longest latency time >20 years: OR = 4.4, 95% CI = 2.2–9.0. Several of the calculations in the long latency category were based on low numbers of exposed cases. Ipsilateral use resulted in a higher risk than contralateral for both mobile and cordless phones. OR increased per 100 h cumulative use and per year of latency for mobile phones and cordless phones, though the increase was not statistically significant for cordless phones. The percentage tumour volume increased per year of latency and per 100 h of cumulative use, statistically significant for analogue phones. This study confirmed previous results demonstrating an association between mobile and cordless phone use and acoustic neuroma. PMID:23877578
Electron transport in stretched monoatomic gold wires.
Grigoriev, A; Skorodumova, N V; Simak, S I; Wendin, G; Johansson, B; Ahuja, R
2006-12-08
The conductance of monoatomic gold wires containing 3-7 gold atoms has been obtained from ab initio calculations. The transmission is found to vary significantly depending on the wire stretching and the number of incorporated atoms. Such oscillations are determined by the electronic structure of the one-dimensional (1D) part of the wire between the contacts. Our results indicate that the conductivity of 1D wires can be suppressed without breaking the contact.
Stewart, Catherine; Kopinski, Hannah; Liebschutz, Jane; Holmdahl, Inga; Keosaian, Julia; Herman, Debra; Anderson, Bradley; Stein, Michael
2018-03-01
Studies of drug-using populations often restrict enrollment by limiting participation to those with a working telephone. It is unknown whether supplying phones could broaden recruitment and sustain retention among an urban population of people who inject drugs (PWID). We compare the feasibility of offering pay-by-month phones to gift card compensation as part of an ongoing randomized controlled trial of hospitalized PWID. Participants were recruited from inpatient services at an urban hospital in Boston, MA to participate in an ongoing randomized trial testing a motivational interviewing (MI) intervention. Participants who did not have their own phone at the time of enrollment were offered a pay-by-month phones as compensation for study participation. Eighty-one participants met study criteria, were enrolled, and completed the study at the time of analysis. We used a generalized estimating equation to compare the overall likelihood of attending interviews during the 12-month follow-up period. Participants receiving phones tended to have lower mean educational attainment (11.4 years vs. 12.1 years), were significantly (Fisher's exact p < 0.001) more likely to report homelessness during the past 90 days (86.7% vs. 37.3%), and were significantly less likely (Fisher's exact p = .044) to be employed (3.3% vs. 20.4%) compared to those receiving gift cards. Participants in each group were equally likely to attend follow-up interviews during the study (83.3% vs. 88.3%, p = 0.53). Offering phones as a compensation method allows recruitment of a more disenfranchised population without impacting study retention and therefore may improve generalizability of study results. Copyright © 2018 Elsevier B.V. All rights reserved.
Hunter, John F; Hooker, Emily D; Rohleder, Nicolas; Pressman, Sarah D
2018-05-01
Mobile phones are increasingly becoming a part of the social environment, and when individuals feels excluded during a socially stressful situation, they often retreat to the comfort of their phone to ameliorate the negativity. This study tests whether smartphone presence does, in fact, alter psychological and physiological responses to social stress. Participants (N = 148, 84% female, mean age = 20.4) were subjected to a peer, social-exclusion stressor. Before exclusion, participants were randomized to one of the following three conditions: (1) phone-present with use encouraged, (2) phone-present with use restricted, or (3) no phone access. Saliva samples and self-report data were collected throughout the study to assess salivary alpha amylase (sAA), cortisol, and feelings of exclusion. Participants in both phone-present conditions reported lower feelings of exclusion compared with individuals who had no access to their phone (F(2,143) = 5.49, p = .005). Multilevel modeling of sAA responses revealed that the individuals in the restricted-phone condition had a significantly different quadratic trajectory after the stressor compared with the phone use (υ = -0.12, z = -2.15, p = .032), and no-phone conditions (υ = -0.14, z = -2.64, p = .008). Specifically, those in the restricted-phone condition showed a decrease in sAA after exclusion, those in the no-phone condition showed a gradual increase, and phone users exhibited little change. Cortisol responses to the stressor did not vary by condition. Taken together, these results suggest that the mere presence of a phone (and not necessarily phone use) can buffer against the negative experience and effects of social exclusion.
Solar Power Wires Based on Organic Photovoltaic Materials
NASA Astrophysics Data System (ADS)
Lee, Michael R.; Eckert, Robert D.; Forberich, Karen; Dennler, Gilles; Brabec, Christoph J.; Gaudiana, Russell A.
2009-04-01
Organic photovoltaics in a flexible wire format has potential advantages that are described in this paper. A wire format requires long-distance transport of current that can be achieved only with conventional metals, thus eliminating the use of transparent oxide semiconductors. A phase-separated, photovoltaic layer, comprising a conducting polymer and a fullerene derivative, is coated onto a thin metal wire. A second wire, coated with a silver film, serving as the counter electrode, is wrapped around the first wire. Both wires are encased in a transparent polymer cladding. Incident light is focused by the cladding onto to the photovoltaic layer even when it is completely shadowed by the counter electrode. Efficiency values of the wires range from 2.79% to 3.27%.
Multiwire Thermocouples in Reversing Flow
NASA Technical Reports Server (NTRS)
Forney, L. J.; Fralick, G. C.
1995-01-01
Measurements are recorded for multiwire thermocouples consisting of either two or three wires of unequal diameters. Signals from the multiwire probe are recorded for a reversing gas flow with both a periodic temperature and time constant fluctuation. It is demonstrated that the reconstructed signal from the multiwire thermocouple requires no compensation provided omega/omega(sub 1) less than 2.3 for two wires or omega/omega(sub 1) less than 3.6 for three wires where omega(sub 1) (= 2(pi)f) is the natural frequency of the smaller wire based on the maximum gas velocity. The latter results were possible provided Fourier transformed data from the wires were used and knowledge of the gas velocity phase angle was available.
Environmental Influence of Gravity and Pressure on Arc Tracking of Insulated Wires Investigated
NASA Technical Reports Server (NTRS)
2005-01-01
Momentary short-circuit arcs between a defective polyimide-insulated wire and another conductor may thermally char (pyrolize) the insulating material. The charred polyimide, being conductive, can sustain the short-circuit arc, which may propagate along the wire through continuous pyrolization of the polyimide insulation (arc tracking). If the arcing wire is part of a multiple-wire bundle, the polyimide insulation of other wires within the bundle may become thermally charred and start arc tracking also (flash over). Such arc tracking can lead to complete failure of an entire wire bundle, causing other critical spacecraft or aircraft failures. Unfortunately, all tested candidate wire insulations for aerospace vehicles were susceptible to arc tracking. Therefore, a test procedure was designed at the NASA Lewis Research Center to select the insulation type least susceptible to arc tracking. This test procedure addresses the following three areas of concern: (1) probability of initiation, (2) probability of reinitiation (restrike), and (3) extent of arc tracking damage (propagation rate). Item 2 (restrike probability) is an issue if power can be terminated from and reapplied to the arcing wire (by a switch, fuse, or resettable circuit breaker). The degree of damage from an arcing event (item 3) refers to how easily the arc chars nearby insulation and propagates along the wire pair. Ease of nearby insulation charring can be determined by measuring the rate of arc propagation. Insulation that chars easily will propagate the arc faster than insulation that does not char very easily. A popular polyimide insulated wire for aerospace vehicles, MIL-W-81381, was tested to determine a degree of damage from an arcing event (item 3) in the following three environments: (1) microgravity with air at 1-atm pressure, (2) 1g with air at 1 atm, and (3) 1g within a 10^-6 Torr vacuum. The microgravity 1-atm air was the harshest environment, with respect to the rate of damage of arc tracking, for the 20 AWG (American Wiring Gauge) MIL-W-81381 wire insulation type . The vacuum environment resulted in the least damage. Further testing is planned to determine if the environmental results are consistent between insulation types and to evaluate the other two parameters associated with arc tracking susceptibility.
Cavaliere, Fabio; Nestola, Valeria; Amadio, Susanna; D'Ambrosi, Nadia; Angelini, Daniela F; Sancesario, Giuseppe; Bernardi, Giorgio; Volonté, Cinzia
2005-02-01
Extracellular nucleotides exert a variety of biological actions through different subtypes of P2 receptors. Here we characterized in the human neuroblastoma SH-SY5Y cells the simultaneous presence of various P2 receptors, belonging to the P2X ionotropic and P2Y metabotropic families. Western blot analysis detected the P2X1,2,4,5,6,7 and P2Y1,2,4,6, but not the P2X3 and P2Y12 receptors. We then investigated which biological effects were mediated by the P2Y4 subtype and its physiological pyrimidine agonist UTP. We found that neuronal differentiation of the SH-SY5Y cells with dibutiryl-cAMP increased the expression of the P2Y4 protein and that UTP itself was able to positively interfere with neuritogenesis. Moreover, transient transfection and activation of P2Y4 also facilitated neuritogenesis in SH-SY5Y cells, as detected by morphological phase contrast analysis and confocal examination of neurofilament proteins NFL. This was concurrent with increased transcription of immediate-early genes linked to differentiation such as cdk-5 and NeuroD6, and activity of AP-1 transcription family members such as c-fos, fos-B, and jun-D. Nevertheless, a prolonged activation of the P2Y4 receptor by UTP also induced cell death, both in naive, differentiated, and P2Y4-transfected SH-SY5Y cells, as measured by direct count of intact nuclei and cytofluorimetric analysis of damaged DNA. Taken together, our data indicate that the high expression and activation of the P2Y4 receptor participates in the neuronal differentiation and commitment to death of SH-SY5Y cells.
Amsailale, Rachid; Van Den Neste, Eric; Arts, Angélique; Starczewska, Eliza; Bontemps, Françoise; Smal, Caroline
2012-07-01
Deoxycytidine kinase (dCK) (EC 2.7.1.74) is a key enzyme in the activation of several therapeutic nucleoside analogs (NA). Its activity can be increased in vivo by Ser-74 phosphorylation, a property that could be used for enhancing NA activation and clinical efficacy. In line with this, studies with recombinant dCK showed that mimicking Ser-74 phosphorylation by a S74E mutation increases its activity toward pyrimidine analogs. However, purine analogs had not been investigated. Here, we show that the S74E mutation increased the k(cat) for cladribine (CdA) by 8- or 3-fold, depending on whether the phosphoryl donor was ATP or UTP, for clofarabine (CAFdA) by about 2-fold with both ATP and UTP, and for fludarabine (F-Ara-A) by 2-fold, but only with UTP. However, the catalytic efficiencies (k(cat)/Km) were not, or slightly, increased. The S74E mutation also sensitized dCK to feed-back inhibition by dCTP, regardless of the phosphoryl donor. Importantly, we did not observe an increase of endogenous dCK activity toward purine analogs after in vivo-induced increase of Ser-74 phosphorylation. Accordingly, treatment of CLL cells with aphidicolin, which enhances dCK activity through Ser-74 phosphorylation, did not modify the conversion of CdA or F-Ara-A into their active triphosphate form. Nevertheless, the same treatment enhanced activation of gemcitabine (dFdC) into dFdCTP in CLL as well as in HCT-116 cells and produced synergistic cytotoxicity. We conclude that increasing phosphorylation of dCK on Ser-74 might constitute a valuable strategy to enhance the clinical efficacy of some NA, like dFdC, but not of CdA or F-Ara-A. Copyright © 2012 Elsevier Inc. All rights reserved.
Superconducting wires and methods of making thereof
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, Xingchen; Sumption, Michael D.; Peng, Xuan
Disclosed herein are superconducting wires. The superconducting wires can comprise a metallic matrix and at least one continuous subelement embedded in the matrix. Each subelement can comprise a non-superconducting core, a superconducting layer coaxially disposed around the non-superconducting core, and a barrier layer coaxially disposed around the superconducting layer. The superconducting layer can comprise a plurality of Nb.sub.3Sn grains stabilized by metal oxide particulates disposed therein. The Nb.sub.3Sn grains can have an average grain size of from 5 nm to 90 nm (for example, from 15 nm to 30 nm). The superconducting wire can have a high-field critical current densitymore » (J.sub.c) of at least 5,000 A/mm.sup.2 at a temperature of 4.2 K in a magnetic field of 12 T. Also described are superconducting wire precursors that can be heat treated to prepare superconducting wires, as well as methods of making superconducting wires.« less
Eun, So Young; Park, Sang Won; Lee, Jae Heun; Chang, Ki Churl; Kim, Hye Jung
2014-04-01
Lipoprotein oxidation, inflammation, and immune responses involving the vascular endothelium and immune cells contribute to the pathogenesis of atherosclerosis. In an atherosclerotic animal model, P2Y2 receptor (P2Y2R) upregulation and stimulation were previously shown to induce intimal hyperplasia and increased intimal monocyte infiltration. Thus, we investigated the role of P2Y2R in oxidized low-density lipoprotein (oxLDL)-mediated oxidative stress and the subsequent interaction between endothelial cells (ECs) and immune cells. The treatment of human ECs with oxLDL caused the rapid release of ATP (maximum after 5 min). ECs treated with oxLDL or the P2Y2R agonists ATP/UTP for 1h exhibited significant reactive oxygen species (ROS) production, but this effect was not observed in P2Y2R siRNA-transfected ECs. In addition, oxLDL and ATP/UTP both induced RAGE expression, which was P2Y2R dependent. Oxidized LDL- and ATP/UTP-mediated ROS production was diminished in RAGE siRNA-transfected ECs, suggesting that RAGE is an important mediator in P2Y2R-mediated ROS production. Treatment with oxLDL for 24h induced P2Y2R expression in the human monocyte cell line THP-1 and increased THP-1 cell migration toward ECs. The addition of apyrase, an enzyme that hydrolyzes nucleotides, or diphenyleneiodonium (DPI), a well-known inhibitor of NADPH oxidase, significantly inhibited the increase in cell migration caused by oxLDL. P2Y2R siRNA-transfected THP-1 cells did not migrate in response to oxLDL or ATP/UTP treatment, indicating a critical role for P2Y2R and nucleotide release in oxLDL-induced monocyte migration. Last, oxLDL and ATP/UTP effectively increased ICAM-1 and VCAM-1 expression and the subsequent binding of THP-1 cells to ECs, which was inhibited by pretreatment with DPI or by siRNA against P2Y2R or RAGE, suggesting that P2Y2R is an important mediator in oxLDL-mediated monocyte adhesion to ECs through the regulation of ROS-dependent adhesion molecule expression in ECs. Taken together, our findings suggest that P2Y2R could be a therapeutic target for the prevention of vascular disorders, including atherosclerosis. Copyright © 2014 Elsevier Inc. All rights reserved.
RCS of resonant scatterers with attached wires
NASA Astrophysics Data System (ADS)
Trueman, C. W.; Mishra, S. R.; Kubina, S. J.; Larose, C. L.
1993-03-01
Some aircraft carry wire antennas for HF communication. This paper investigates the effect of such wires on the radar cross section (RCS) at HF frequencies by comparing the RCS of a strip, a cylinder, and a rod with and without an attached wire. The RCS is found for broadside incidence and for end-on incidence of the plane wave for scatterer lengths from 0.4 to 3.8 wavelengths, typical of aircraft size at HF frequencies. It is shown that the RCS of such fuselage-like targets with a wire 'antenna' is quite different from that of the targets without the wire. For broadside incidence, the wire contributes a sharp peak-and-trough to the RCS at the wire's fundamental resonant frequency. For end-on incidence the wire considerably enhances the RCS at frequencies making its length odd multiples of the quarter-wave.
Arnold, Dario T; Dalstra, Michel; Verna, Carlalberta
2016-06-01
Movements of teeth splinted by fixed retention wires after orthodontic treatment have been observed. The aetiological factors for these movements are unknown. The aim of this in vitro study was to compare the resistance to torque of different stainless steel wires commonly used for fixed retainers in orthodontics. Torquing moments acting on a retainer wire were measured in a mechanical force testing system by applying buccal crown torque to an upper lateral incisor in both a 3-teeth and in a 2-teeth setup. Seven stainless steel wires with different shape, type (plain, braided, coaxial, or chain) and dimensions were selected for this study. For a torquing angle of 16.2° in the 3-teeth setup torsion moments can vary between 390 cNmm and 3299 cNmm depending on the retainer wire. For the 2-teeth setup the torsion moments are much smaller. Exposure to the flame of a butane-gas torch for 10 seconds to anneal the wire reduces the stiffness of the retainer wire. Clinicians must select wires for fixed retainers very carefully since the difference in resistance to torque is large. A high level of torque control can be achieved with a plain 0.016 × 0.016-inch or a braided 0.016 × 0.022-inch stainless steel wire. A tooth attached by a retainer wire to only one neighbouring tooth is less resistant to torque than a tooth connected to two neighbouring teeth. Annealing a retainer wire with a flame reduces the stiffness of the wire markedly and can lead to a non-uniform and non-reproducible effect.
Perceptions and attitudes of hospital staff toward paging system and the use of mobile phones.
Haroon, Muhammad; Yasin, Faiza; Eckel, Rachael; Walker, Frank
2010-10-01
Our objective was to document the pattern of mobile phone usage by medical staff in a hospital setting, and to explore any perceived benefits (such as improved communications) associated with mobile phones. This cross-sectional survey was conducted in Waterford Regional Hospital, Ireland, where bleep is the official system of communication. All non-consultant hospital doctors, of medical disciplines only, were asked to participate. The questionnaire was designed to explore the pattern and different aspects of mobile phone usage. At the time of study, there were sixty medical junior doctors, and the response rate was 100 percent. All participants used mobile phones while at work, and also for hospital-related work. For 98.3 percent the mobile phone was their main mode of communication while in the hospital. Sixty-two percent (n = 37) made 6-10 calls daily purely for work-related business, and this comprised of ≥ 80 percent of their daily usage of mobile phones. For 98 percent of participants, most phone calls were work-related. Regarding reasons for using mobile phones, all reported that using mobile phone is quicker for communication. Mobile phone usage is very common among the medical personnel, and this is regarded as a more efficient means of communication for mobile staff than the hospital paging system.
Study Regarding Electromagnetic Radiation Exposure Generated By Mobile Phone
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marica, Lucia; Moraru, Luminita
Number of mobile phone users reached to 5 billion subscribers in 2010 [ABI Research, 2010]. A large number of studies illustrated the public concern about adverse effects of mobile phone radiation and possible health hazards. Position of mobile phone use in close proximity to the head leads the main radiation between the hand and the head. Many investigations studying the possible effects of mobile phone exposure, founded no measurable effects of short-term mobile phone radiation, and there was no evidence for the ability to perceive mobile phone EMF in the general population. In this study, field radiation measurements were performedmore » on different brand and different models of mobile phones in active mode, using an EMF RF Radiation Field Strength Power Meter 1 MHz-8 GHz. The study was effectuated on both the 2G and 3G generations phones connected to the providers operating in the frequency range 450 MHz-1800 MHz. There were recorded values in outgoing call and SMS mode, incoming call and SMS mode. Results were compared with ICNIRP guidelines for exposure to general public.« less
Dietrich, Janan J; Lazarus, Erica; Andrasik, Michele; Hornschuh, Stefanie; Otwombe, Kennedy; Morgan, Cecilia; Isaacs, Abby J; Huang, Yunda; Laher, Fatima; Kublin, James G; Gray, Glenda E
2018-03-29
Recall and social desirability bias undermine self-report of paper-and-pencil questionnaires. Mobile phone questionnaires may overcome these challenges. We assessed and compared sexual risk behavior reporting via in-clinic paper-and-pencil and mobile phone questionnaires. HVTN 915 was a prospective cohort study of 50 adult women in Soweto, who completed daily mobile phone, and eight interviewer-administered in-clinic questionnaires over 12 weeks to assess sexual risk. Daily mobile phone response rates were 82% (n = 3486/4500); 45% (n = 1565/3486) reported vaginal sex (median sex acts 2 (IQR: 1-3)) within 24 h and 40% (n = 618/1565) consistent condom. Vaginal sex reporting was significantly higher via mobile phone across all visits (p < 0.0001). There was no significant difference in condom use reporting by mobile phone and in-clinic paper-based questionnaires across all visits (p = 0.5134). The results show high adherence and reporting of sex on the mobile phone questionnaire. We demonstrate feasibility in collecting mobile phone sexual risk data.
Study Regarding Electromagnetic Radiation Exposure Generated By Mobile Phone
NASA Astrophysics Data System (ADS)
Marica, Lucia; Moraru, Luminita
2011-12-01
Number of mobile phone users reached to 5 billion subscribers in 2010 [ABI Research, 2010]. A large number of studies illustrated the public concern about adverse effects of mobile phone radiation and possible health hazards. Position of mobile phone use in close proximity to the head leads the main radiation between the hand and the head. Many investigations studying the possible effects of mobile phone exposure, founded no measurable effects of short-term mobile phone radiation, and there was no evidence for the ability to perceive mobile phone EMF in the general population. In this study, field radiation measurements were performed on different brand and different models of mobile phones in active mode, using an EMF RF Radiation Field Strength Power Meter 1 MHz-8 GHz. The study was effectuated on both the 2G and 3G generations phones connected to the providers operating in the frequency range 450 MHz-1800 MHz. There were recorded values in outgoing call and SMS mode, incoming call and SMS mode. Results were compared with ICNIRP guidelines for exposure to general public.
Pesnya, Dmitry S; Romanovsky, Anton V
2013-01-20
The goal of this study was to compare the cytotoxic and genotoxic effects of plutonium-239 alpha particles and GSM 900 modulated mobile phone (model Sony Ericsson K550i) radiation in the Allium cepa test. Three groups of bulbs were exposed to mobile phone radiation during 0 (sham), 3 and 9h. A positive control group was treated during 20min with plutonium-239 alpha-radiation. Mitotic abnormalities, chromosome aberrations, micronuclei and mitotic index were analyzed. Exposure to alpha-radiation from plutonium-239 and exposure to modulated radiation from mobile phone during 3 and 9h significantly increased the mitotic index. GSM 900 mobile phone radiation as well as alpha-radiation from plutonium-239 induced both clastogenic and aneugenic effects. However, the aneugenic activity of mobile phone radiation was more pronounced. After 9h of exposure to mobile phone radiation, polyploid cells, three-groups metaphases, amitoses and some unspecified abnormalities were detected, which were not registered in the other experimental groups. Importantly, GSM 900 mobile phone radiation increased the mitotic index, the frequency of mitotic and chromosome abnormalities, and the micronucleus frequency in a time-dependent manner. Due to its sensitivity, the A. cepa test can be recommended as a useful cytogenetic assay to assess cytotoxic and genotoxic effects of radiofrequency electromagnetic fields. Copyright © 2012 Elsevier B.V. All rights reserved.
Laser Annealing on the Surface Treatment of Thin Super Elastic NiTi Wire
NASA Astrophysics Data System (ADS)
Samal, S.; Heller, L.; Brajer, J.; Tyc, O.; Kadrevek, L.; Sittner, P.
2018-05-01
Here the aim of this research is annealing the surface of NiTi wire for shape memory alloy, super-elastic wire by solid state laser beam. The laser surface treatment was carried out on the NiTi wire locally with fast, selective, surface heat treatment that enables precisely tune the localized material properties without any precipitation. Both as drawn (hard) and straight annealing NiTi wire were considered for laser annealing with input power 3 W, with precisely focusing the laser beam height 14.3 % of the Z-axis with a spot size of 1 mm. However, straight annealing wire is more interest due to its low temperature shape setting behavior and used by companies for stent materials. The variable parameter such as speed of the laser scanning and tensile stress on the NiTi wire were optimized to observe the effect of laser response on the sample. Superelastic, straight annealed NiTi wires (d: 0.10 mm) were held prestrained at the end of the superelastic plateau (ε: 5 ∼6.5 %) above the superelastic region by a tensile machine ( Mitter: miniature testing rig) at room temperature (RT). Simultaneously, the hardness of the wires along the cross-section was performed by nano-indentation (NI) method. The hardness of the NiTi wire corresponds to phase changes were correlated with NI test. The laser induced NiTi wire shows better fatigue performance with improved 6500 cycles.
47 CFR 69.725 - Attribution of revenues to particular wire centers.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 3 2010-10-01 2010-10-01 false Attribution of revenues to particular wire... particular wire centers. If a price cap LEC elects to show, in accordance with § 69.709 or § 69.711, that competitors have collocated in wire centers accounting for a certain percentage of revenues from the services...
47 CFR 69.725 - Attribution of revenues to particular wire centers.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 3 2011-10-01 2011-10-01 false Attribution of revenues to particular wire... particular wire centers. If a price cap LEC elects to show, in accordance with § 69.709 or § 69.711, that competitors have collocated in wire centers accounting for a certain percentage of revenues from the services...
46 CFR 108.497 - Fireman's outfits.
Code of Federal Regulations, 2010 CFR
2010-10-01
... belt or a suitable harness; (2) Is made of bronze wire rope, inherently corrosion resistant steel wire rope, or galvanized or tinned steel wire rope; (3) Is made up of enough 15.2 meters (50 foot) or greater lengths of wire rope to permit use of the outfit in any location on the unit; (4) Has each end...
46 CFR 108.497 - Fireman's outfits.
Code of Federal Regulations, 2011 CFR
2011-10-01
... belt or a suitable harness; (2) Is made of bronze wire rope, inherently corrosion resistant steel wire rope, or galvanized or tinned steel wire rope; (3) Is made up of enough 15.2 meters (50 foot) or greater lengths of wire rope to permit use of the outfit in any location on the unit; (4) Has each end...
46 CFR 108.497 - Fireman's outfits.
Code of Federal Regulations, 2013 CFR
2013-10-01
... belt or a suitable harness; (2) Is made of bronze wire rope, inherently corrosion resistant steel wire rope, or galvanized or tinned steel wire rope; (3) Is made up of enough 15.2 meters (50 foot) or greater lengths of wire rope to permit use of the outfit in any location on the unit; (4) Has each end...
46 CFR 108.497 - Fireman's outfits.
Code of Federal Regulations, 2014 CFR
2014-10-01
... belt or a suitable harness; (2) Is made of bronze wire rope, inherently corrosion resistant steel wire rope, or galvanized or tinned steel wire rope; (3) Is made up of enough 15.2 meters (50 foot) or greater lengths of wire rope to permit use of the outfit in any location on the unit; (4) Has each end...
46 CFR 108.497 - Fireman's outfits.
Code of Federal Regulations, 2012 CFR
2012-10-01
... belt or a suitable harness; (2) Is made of bronze wire rope, inherently corrosion resistant steel wire rope, or galvanized or tinned steel wire rope; (3) Is made up of enough 15.2 meters (50 foot) or greater lengths of wire rope to permit use of the outfit in any location on the unit; (4) Has each end...
Mountain Plains Learning Experience Guide: Electrical Wiring. Course: Electrical Wiring Rough-In.
ERIC Educational Resources Information Center
Arneson, R.; And Others
One of two individualized courses included in an electrical wiring curriculum, this course covers electrical installations that are generally hidden within the structure. The course is comprised of four units: (1) Outlet and Switch Boxes, (2) Wiring, (3) Service Entrance, and (4) Signal and Low Voltage Systems. Each unit begins with a Unit…
Synthesis of chemical vapor deposition graphene on tantalum wire for supercapacitor applications
NASA Astrophysics Data System (ADS)
Li, Mingji; Guo, Wenlong; Li, Hongji; Xu, Sheng; Qu, Changqing; Yang, Baohe
2014-10-01
This paper studies the synthesis and electrochemical characterization of graphene/tantalum (Ta) wires as high-performance electrode material for supercapacitors. Graphene on Ta wires is prepared by the thermal decomposition of methane under various conditions. The graphene nanosheets on the Ta wire surface have an average thickness of 1.3-3.4 nm and consist typically of a few graphene monolayers, and TaC buffer layers form between the graphene and Ta wire. A capacitor structure is fabricated using graphene/Ta wire with a length of 10 mm and a diameter of 0.6 mm as the anode and Pt wire of the same size as the cathode. The electrochemical behavior of the graphene/Ta wires as supercapacitor electrodes is characterized by cyclic voltammetry, galvanostatic charge/discharge, and electrochemical impedance spectroscopy in 1 M Na2SO4 aqueous electrolyte. The as-prepared graphene/Ta electrode has highest capacitance of 345.5 F g-1 at current density of 0.5 A g-1. The capacitance remains at about 84% after 1000 cycles at 10 A g-1. The good electrochemical performance of the graphene/Ta wire electrode is attributed to the unique nanostructural configuration, high electrical conductivity, and large specific surface area of the graphene layer. This suggests that graphene/Ta wire electrode materials have potential applications in high-performance energy storage devices.
Bound Electron States in Skew-symmetric Quantum Wire Intersections
2014-01-01
18 1.2.3 Kirchhoffs Rule for Quantum Wires . . . . . . . . . . . 19 1.3 Novel numerical methods development . . . . . . . . . . . . . 19 2...regions, though this is not as obvious as it is for bulges. CHAPTER 1. LITERATURE REVIEW 19 1.2.3 Kirchhoffs Rule for Quantum Wires One particle quantum...scattering theory on an arbitrary finite graph with n open ends and where we define the Hamiltonian to be (minus) the Laplace operator with general
Kaneko, Umihiko; Kashima, Yoshifumi; Kanno, Daitaro; Sugie, Takuro; Kobayashi, Ken; Fujita, Tsutomu
2017-10-01
Although performing rotational atherectomy (RA) requires guidewire exchange for the dedicated guidewire, RotaWire guidewire (Boston Scientific) exhibits much lower performance than conventional guidewire. Consequently, there are times when RotaWire cannot be advanced past the lesion independently or using a microcatheter exchange technique, rendering RA impossible. We present a case of a heavily calcified, device-uncrossable, and non-expansible chronic total occlusion lesion successfully revascularized with RA over RG3 guidewire (Asahi Intecc), which has a length of 330 cm, hydrophilic coating, and a 0.010-inch-long shaft. RG3 provided excellent cross-ability and RA could also be performed over RG3 without guidewire exchange for the RotaWire.
Guxens, Mònica; van Eijsden, Manon; Vermeulen, Roel; Loomans, Eva; Vrijkotte, Tanja G M; Komhout, Hans; van Strien, Rob T; Huss, Anke
2013-05-01
A previous study found an association between maternal cell phone use during pregnancy and maternal-reported child behaviour problems at age 7. Together with cell phones, cordless phones represent the main exposure source of radiofrequency-electromagnetic fields to the head. Therefore, we assessed the association between maternal cell phone and cordless phone use during pregnancy and teacher-reported and maternal-reported child behaviour problems at age 5. The study was embedded in the Amsterdam Born Children and their Development study, a population-based birth cohort study in Amsterdam, the Netherlands (2003-2004). Teachers and mothers reported child behaviour problems using the Strength and Difficulties Questionnaire at age 5. Maternal cell phone and cordless phone use during pregnancy was asked when children were 7 years old. A total of 2618 children were included. As compared to non-users, those exposed to prenatal cell phone use showed an increased but non-significant association of having teacher-reported overall behaviour problems, although without dose-response relationship with the number of calls (OR=2.12 (95% CI 0.95 to 4.74) for <1 call/day, OR=1.58 (95% CI 0.69 to 3.60) for 1-4 calls/day and OR=2.04 (95% CI 0.86 to 4.80) for ≥5 calls/day). ORs for having teacher-reported overall behaviour problems across categories of cordless phone use were below 1 or close to unity. Associations of maternal cell phone and cordless phone use with maternal-reported overall behaviour problems remained non-significant. Non-significant associations were found for the specific behaviour problem subscales. Our results do not suggest that maternal cell phone or cordless phone use during pregnancy increases the odds of behaviour problems in their children.
Mechanical properties and aesthetics of FRP orthodontic wire fabricated by hot drawing.
Imai, T; Watari, F; Yamagata, S; Kobayashi, M; Nagayama, K; Toyoizumi, Y; Nakamura, S
1998-12-01
The FRP wires 0.5 mm in diameter with a multiple fiber structure were fabricated by drawing the fiber polymer complex at 250 degrees C for an esthetic, transparent orthodontic wire. Biocompatible CaO-P2O5-SiO2-Al2O3 (CPSA) glass fibers of 8-20 microm in diameter were oriented unidirectionally in the longitudinal direction in PMMA matrix. The mechanical properties were investigated by 3-point flexural test. The FRP wire showed sufficient strength and a very good elastic recovery after deformation. Young's modulus and the flexural load at deflection 1 mm were nearly independent of the fiber diameter and linearly increased with the fiber fraction. The dependence on fiber fraction obeys well the rule of mixture. This FRP wire could cover the range of strength corresponding to the conventional metal orthodontic wires from Ni-Ti used in the initial stage of orthodontic treatments to Co-Cr used in the final stage by changing the volume ratio of glass fibers with the same external diameter. The estheticity in external appearance was excellent. Thus the new FRP wire can satisfy both mechanical properties necessary for an orthodontic wire and enough estheticity, which was not possible for the conventional metal wire.
Relationship of Near-Crash/Crash Risk to Time Spent on a Cell Phone While Driving.
Farmer, Charles M; Klauer, Sheila G; McClafferty, Julie A; Guo, Feng
2015-01-01
The objective of this study was to examine in a naturalistic driving setting the dose-response relationship between cell phone usage while driving and risk of a crash or near crash. How is the increasing use of cell phones by drivers associated with overall near-crash/crash risk (i.e., during driving times both on and off the phone)? Day-to-day driving behavior of 105 volunteer subjects was monitored over a period of 1 year. A random sample was selected comprised of 4 trips from each month that each driver was in the study, and in-vehicle video was used to classify driver behavior. The proportion of driving time spent using a cell phone was estimated for each 3-month period and correlated with overall crash and near-crash rates for each period. Thus, it was possible to test whether changes in an individual driver's cell phone use over time were associated with changes in overall near-crash/crash risk. Drivers in the study spent 11.7% of their driving time interacting with a cell phone, primarily talking on the phone (6.5%) or simply holding the phone in their hand or lap (3.7%). The risk of a near-crash/crash event was approximately 17% higher when the driver was interacting with a cell phone, due primarily to actions of reaching for/answering/dialing, which nearly triples risk (relative risk = 2.84). However, the amount of driving time spent interacting with a cell phone did not affect a driver's overall near-crash/crash risk. Vehicle speeds within 6 s of the beginning of each call on average were 5-6 mph lower than speeds at other times. Results of this naturalistic driving study are consistent with the observation that increasing cell phone use in the general driving population has not led to increased crash rates. Although cell phone use can be distracting and crashes have occurred during this distraction, overall crash rates appear unaffected by changes in the rate of cell phone use, even for individual drivers. Drivers compensate somewhat for the distraction by conducting some of the more demanding tasks, such as reaching for or dialing a cell phone, at lower speeds. It is also possible that cell phones and other electronic devices in cars are changing how drivers manage their attention to various tasks and/or changing the kinds of secondary tasks in which they engage.
7 CFR 980.117 - Import regulations; onions.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Texas points Officer-in-charge, 1301 West Expressway, Alamo, Tex. 78516. Phone 512-787-4091 or 512-787-6881 1 All Arizona points Officer-in-charge, P.O. Box 1614, Nogales, Ariz. 85621. Phone 602-287-4783 1.... Phone 213-688-2489 3 All Hawaii points Officer-in-charge, P.O. Box 22159, Pawaa Substation, Honolulu...
78 FR 2954 - South Atlantic Fishery Management Council (Council)-Public Meetings
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-15
... Air Force Museum, 175 Bourne Avenue, Pooler, GA 31322; phone: 912/748-8888. 2. January 23, 2013: Hilton Garden Inn, 5265 International Blvd., N. Charleston, SC 29418; phone: 843/308-9330. 3. January 24, 2013: New Bern Riverfront Convention Center, 203 South Front Street, New Bern, NC 28563; phone: 252/637...
22 CFR 96.32 - Internal structure and oversight.
Code of Federal Regulations, 2011 CFR
2011-04-01
... known, under either its current or any former form of organization, and the addresses and phone numbers used when such names were used; (2) The name, address, and phone number of each current director... number of such other provider; and (3) The name, address, and phone number of any entity it uses or...
22 CFR 96.32 - Internal structure and oversight.
Code of Federal Regulations, 2012 CFR
2012-04-01
... known, under either its current or any former form of organization, and the addresses and phone numbers used when such names were used; (2) The name, address, and phone number of each current director... number of such other provider; and (3) The name, address, and phone number of any entity it uses or...
22 CFR 96.32 - Internal structure and oversight.
Code of Federal Regulations, 2014 CFR
2014-04-01
... known, under either its current or any former form of organization, and the addresses and phone numbers used when such names were used; (2) The name, address, and phone number of each current director... number of such other provider; and (3) The name, address, and phone number of any entity it uses or...
22 CFR 96.32 - Internal structure and oversight.
Code of Federal Regulations, 2013 CFR
2013-04-01
... known, under either its current or any former form of organization, and the addresses and phone numbers used when such names were used; (2) The name, address, and phone number of each current director... number of such other provider; and (3) The name, address, and phone number of any entity it uses or...
Method of preparing composite superconducting wire
Verhoeven, John D.; Gibson, Edwin D.; Finnemore, Douglas K.; Ostenson, Jerome E.; Schmidt, Frederick A.; Owen, Charles V.
1985-08-06
An improved method of preparing composite multifilament superconducting wire of Nb.sub.3 Sn in a copper matrix which eliminates the necessity of coating the drawn wire with tin. A generalized cylindrical billet of an alloy of copper containing at least 15 weight percent niobium, present in the copper as discrete, randomly distributed and oriented dendritic-shaped particles, is provided with at least one longitudinal opening which is filled with tin to form a composite drawing rod. The drawing rod is then drawn to form a ductile composite multifilament wire containing a filament of tin. The ductile wire containing the tin can then be wound into magnet coils or other devices before heating to diffuse the tin through the wire to react with the niobium forming Nb.sub.3 Sn. Also described is an improved method for making large billets of the copper-niobium alloy by consumable-arc casting.
Comparison of Arc Tracking Tests in Various Aerospace Environments
NASA Technical Reports Server (NTRS)
Stueber, Thomas J.; Hammoud, Ahmad; McCall, David
1996-01-01
Momentary short-circuit arcs between a polyimide insulated wire with defective insulation and another conductor may cause pyrolization of the insulation resulting in a conductive path capable of sustaining the arc. These sustained arcs may propagate along the wires or to neighboring wires leading to complete failure of the wire bundle. Wire insulation susceptibility to arc tracking may be dependent on its environment. Because all wire insulation types tested to date arc track, a test procedure has been developed to compare different insulation types with respect to their arc tracking susceptibility. This test procedure is presented along with a comparison of arc tracking in the following three environments: (1) Air at atmospheric pressure and 1 gravitational(g) force; (2) Vacuum (2.67 x 10(exp -3) Pa) and 1g, and (3) Air at atmospheric pressure and microgravity (less than 0.04g).
Improved method of preparing composite superconducting wire
Verhoeven, J.D.; Gibson, E.D.; Finnemore, D.K.; Ostenson, J.E.; Schmidt, F.A.; Owen, C.V.
1979-10-17
An improved method of preparing composite multifilament superconducting wire of Nb/sub 3/Sn in a copper matrix eliminates the necessity of coating the drawn wire with tin. A generalized cylindrical billet of an alloy of copper containing at least 15 weight percent niobium, present in the copper as discrete, randomly distributed and oriented dendritic-shaped particles, is provided with at least one longitudinal opening which is filled with tin to form a composite drawing rod. The drawing rod is then drawn to form a ductile composite multifilament wire containing a filament of tin. The ductile wire containing the tin can then be wound into magnet coils or other devices before heating to diffuse the tin through the wire to react with the niobium forming Nb/sub 3/Sn. Also described is an improved method for making large billets of the copper-niobium alloy by consumable-arc casting.
Guide wire entrapment by inferior vena cava filters: an experimental study.
Rosen, Michael J; Burns, Justin M; Cobb, William S; Jacobs, David G; Heniford, B Todd; Sing, Ronald F
2005-09-01
In situ vena cava filters are at risk for complications with the use of J-tipped guide wires. The purpose of this study was to evaluate the impact of two commonly used J-tipped guide wires on the stability of the four most recently released vena cava filters in an in vitro flow model. Four filters (OptEase [F1], Günther Tulip [F2], Vena Tech LP [F3], and Recovery [F4]) were inserted into an in vitro flow model. Two J-tipped guide wires (0.032-inch [GW-1], 0.035-inch [GW-2]) were passed through each filter (n = 50 passes per wire) for a distance of 10 cm. The inserter was blind as to the effects of the wire. The filters were monitored by an independent observer for adverse events occurring between the filters and the guide wires. These were defined as: migrations (>1 cm), change of position (tilt>10 degrees), and entrapment of the wire (unable to remove wire). Descriptive statistics, chi-square, and Fisher's exact test were used (p < 0.05 considered significant). GW-1 resulted in a lower incidence of entrapment, migration, and tilt for all filters compared with GW-2 (F1, p = 0.003; F2, p < 0.0001; F3, p < 0.0001; F4, p = 0.0004). GW-1 resulted in entrapment in 0%, migration in 7.5%, and tilt in 10.5% of insertions. GW-2 resulted in entrapment in 1%, migration in 26.5%, and tilt in 5.5% of insertions. The incidence of adverse events for GW-1 was significantly different compared with all filters (F1, 0%; F2, 46%; F3, 4%; and F4, 22%; p < 0.0001). Similarly, the incidence of adverse events for GW-2 was significantly different when evaluating all filters (F1, 12%; F2, 48%; F3, 22%; F4 60%; p < 0.0001). The smaller-diameter guide wire resulted in a decreased incidence of adverse events for all filters, but there is still risk for complications. Knowledge of potential complications associated with vena cava filters and the postinsertion use of guide wires are essential to avoid potential mishaps.
New Deoxyribonucleic Acid Polymerase Induced by Bacillus subtilis Bacteriophage PBS2
Price, Alan R.; Cook, Sandra J.
1972-01-01
The deoxyribonucleic acid (DNA) of Bacillus subtilis phage PBS2 has been confirmed to contain uracil instead of thymine. PBS2 phage infection of wild-type cells or DNA polymerase-deficient cells results in an increase in the specific activity of DNA polymerase. This induction of DNA polymerase activity is prevented by actinomycin D and chloramphenicol. In contrast to the major B. subtilis DNA polymerase, which prefers deoxythymidine triphosphate (dTTP) to deoxyuridine triphosphate (dUTP), the DNA polymerase in crude extracts of PBS2-infected cells is equally active whether dTTP or dUTP is employed. This phage-induced polymerase may be responsible for the synthesis of uracil-containing DNA during PBS2 phage infection. PMID:4623224
Effects of Recording Food Intake Using Cell Phone Camera Pictures on Energy Intake and Food Choice.
Doumit, Rita; Long, JoAnn; Kazandjian, Chant; Gharibeh, Nathalie; Karam, Lina; Song, Huaxin; Boswell, Carol; Zeeni, Nadine
2016-06-01
The well-documented increases in obesity and unhealthy dietary practices substantiate the need for evidence-based tools that can help people improve their dietary habits. The current spread of mobile phone-embedded cameras offers new opportunities for recording food intake. Moreover, the act of taking pictures of food consumed may enhance visual consciousness of food choice and quantity. The present study aimed to assess the effect of using cell phone pictures to record food intake on energy intake and food choice in college students. The effectiveness and acceptability of cell phone picture-based diet recording also was assessed. A repeated measures crossover design was used. One group of participants entered their food intake online during 3 days based on their memory, although a second group recorded their food intake using cell phone pictures as their reference. Participants then crossed over to complete 3 more days of diet recording using the alternate method. Focus groups were conducted to obtain feedback on the effectiveness and acceptability of cell phone picture-based diet recording. Intake of meat and vegetable servings were significantly higher in the memory period compared with the cell phone period, regardless of the order. Results from the focus group indicated a positive attitude toward the use of cell phone pictures in recording food intake and an increased awareness of food choice and portion size. Cell phone pictures may be an easy, relevant, and accessible method of diet self-monitoring when aiming at dietary changes. Future trials should combine this technique with healthy eating education. © 2015 Sigma Theta Tau International.
Wiinberg, Stig; Samuelsson, Göran; Larsson, Stefan; Nilsson, Barbro; Jönsson, Patrik X; Ivarsson, Bodil; Olofsson, Per-Åke
2017-08-09
National recommendations in Sweden recommend a safety distance of 3 meter (m) between mobile phones and medical-electrical (ME) equipment in hospitals. A questionnaire was used to investigate how often mobile phones were reported to interfere with ME products in clinical practice across Sweden. The results confirmed that ME equipment can be affected by mobile phone use but, the risk of the patient's outcome being affected were minimal; no cases were identified which led to injury or death. In conclusion, the results support recommendations for a general safety distance of 0.5 m between mobile phones and ME equipment in care environments.
Sociotechnical analysis of nurses' use of personal mobile phones at work.
Bautista, John Robert; Lin, Trisha T C
2016-11-01
Nurses' use of personal mobiles phones at work is a growing trend in healthcare organizations. Although recent studies have explored the positive and negative implications of nurses using personal mobile phones at work, none has yet analyzed the interactions of sociotechnical components (users, technology and policy) on nurses' use of personal mobile phones at work. Identify sociotechnical interactions by analyzing each sociotechnical component (users, technology and policy) that affects nurses' use of personal mobile phones at work. In-depth interviews were conducted with 30 nurses employed in 13 hospitals in the Philippines. The respondents include staff nurses (n=23), charge nurses (n=4), and nurse managers (n=3). Staff nurses were asked on their use of personal mobile phones at work, while charge and nurse managers were asked on their observations regarding staff nurses' use of personal mobile phones at work. Responses were analyzed qualitatively using sociotechnical analysis. Sociotechnical analysis indicated that staff nurses used their personal mobile phones at work in various ways because its use helped in their nursing work, but inevitably altered a few of their routines. Although most hospitals had policies that prohibit the use of mobile phones, staff nurses justified their use of personal mobile phones by using it for work purposes and for the benefit of their patients. Staff nurses highlighted the absence of hospital-provided mobile phones as a key reason for using personal mobile phones at work. Charge nurses and nurse managers also influenced staff nurses' use of personal mobile phones at work. Nurses could use their personal mobile phones at work for work purposes to enhance their clinical performance and improve patient care. Hospital administrators can leverage on nurses' use of personal mobile phones at work by formulating policies that consider both the benefits and potential drawbacks of mobile phone usage. Recommendations are made for the formulation of hospital policies to optimize the use of personal mobile phones of nurses at work. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Matras, M. R.; Jiang, J.; Larbalestier, D. C.; Hellstrom, E. E.
2016-10-01
Overpressure (OP) processing increases the critical current density ({{\\boldsymbol{J}}}{{C}}) of Bi2Sr2CaCu2O x (2212) round wires by shrinking the surrounding Ag matrix around the 2212 filaments, driving them close to full density and greatly increasing the 2212 grain connectivity. Indeed densification is vital for attaining the highest {{\\boldsymbol{J}}}{{C}}. Here, we investigate the time and temperature dependence of the wire densification. We find that the wire diameter decreases by 3.8 ± 0.3% after full heat treatment at 50 atm and 100 atm OP. At 50 atm OP pressure, the filaments start densifying above 700 °C and reach a 3.30 ± 0.07% smaller diameter after 2 h at 820 °C, which is below the melting point of 2212 powder. The densification is homogeneous and does not change the filament shape before melting. The growth of non-superconducting phases is observed at 820 °C, suggesting that time should be minimized at high temperature prior to melting the 2212 powder. Study of an open-ended 2.2 m long wire sample shows that full densification and the high OP {{\\boldsymbol{J}}}{{C}} ({{\\boldsymbol{J}}}{{C}} varies by about 3.1 times over the 2.2 m long wire) is reached about 1 m from the open ends, thus showing that coil-length wires can be protected from leaky seals by adding at least 1 m of sacrificial wire at each end.
Ferroelectric and photocatalytic behavior of bismuth ferrite nano wire
NASA Astrophysics Data System (ADS)
William, R. V.; Marikani, A.; Madhavan, D.
2016-05-01
Multiferroic bismuth ferrite nanowires are prepared through polyol method with an average diameter of 35 nm with a narrow size distribution. The band gap was determined to be 2.10 eV, indicating their potential application as visible-light-response photo catalyst. The magnificent photocatalytic behaviors of BiFeO3 nanowires are understood from the methyl violet degradation under visible light irradiation. Moreover, the nano-wire takes only a lesser time for the diffusion of electron-hole pair from the surface of the sample. Further the BiFeO3 nano-wire was characterized using XRD, SEM, and U-V. The ferroelectric studies of BiFeO3 nano-wire show a frequency dependent property and maximum coercivity of 2.7 V/cm were achieved with a remanent polarization at 0.5 µC/cm2 at the frequency 4 kHz. The coercivity of BiFeO3 nano wire changes with variation of frequency from 1 kHz to 4 kHz.
30 CFR 75.517-2 - Plans for insulation of existing bare power wires and cables.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Equipment-General § 75.517-2 Plans for insulation of existing bare power wires and cables. (a) On or before December 31, 1970, plans for the insulation of existing bare power wires and cables installed prior to... officials; (2) Map or diagram indicating location of power wires and cables required to be insulated; (3...
30 CFR 75.517-2 - Plans for insulation of existing bare power wires and cables.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Equipment-General § 75.517-2 Plans for insulation of existing bare power wires and cables. (a) On or before December 31, 1970, plans for the insulation of existing bare power wires and cables installed prior to... officials; (2) Map or diagram indicating location of power wires and cables required to be insulated; (3...
30 CFR 75.517-2 - Plans for insulation of existing bare power wires and cables.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Equipment-General § 75.517-2 Plans for insulation of existing bare power wires and cables. (a) On or before December 31, 1970, plans for the insulation of existing bare power wires and cables installed prior to... officials; (2) Map or diagram indicating location of power wires and cables required to be insulated; (3...
Wire-type MnO2/Multilayer graphene/Ni electrode for high-performance supercapacitors
NASA Astrophysics Data System (ADS)
Hu, Minglei; Liu, Yuhao; Zhang, Min; Wei, Helin; Gao, Yihua
2016-12-01
Commercially available wearable energy storage devices need a wire-type electrode with high strength, conductivity and electrochemical performance, as well as stable structure under deformation. Herein, we report a novel wire-type electrode of hierarchically structure MnO2 on Ni wire with multilayer graphene (MGr) as a buffer layer to enhance the electrical conductivity of the MnO2 and interface contact between the MnO2 and Ni wire. Thus, the wire-type MnO2/MGr/Ni electrode has a stable and high quality interface. The wire-type supercapacitor (WSC) based on wire-type MnO2/MGr/Ni electrode exhibits good electrochemical performance, high rate capability, extraordinary flexibility, and superior cycle lifetime. Length (area, volumetric) specific capacitance of the WSC reaches 6.9 mF cm-1 (73.2 mF cm-2, 9.8 F cm-3). Maximum length (volumetric) energy density of the WSC based on MnO2/MGr/Ni reaches 0.62 μWh cm-1 (0.88 mWh cm-3). Furthermore, the WSC has a short time constant (0.5-400 ms) and exhibits minimal change in capacitance under different bending shapes.
Archambault, Amy; Major, Thomas W; Carey, Jason P; Heo, Giseon; Badawi, Hisham; Major, Paul W
2010-09-01
The force moment providing rotation of the tooth around the x-axis (buccal-lingual) is referred to as torque expression in orthodontic literature. Many factors affect torque expression, including the wire material characteristics. This investigation aims to provide an experimental study into and comparison of the torque expression between wire types. With a worm-gear-driven torquing apparatus, wire was torqued while a bracket mounted on a six-axis load cell was engaged. Three 0.019 x 0.0195 inch wire (stainless steel, titanium molybdenum alloy [TMA], copper nickel titanium [CuNiTi]), and three 0.022 inch slot bracket combinations (Damon 3MX, In-Ovation-R, SPEED) were compared. At low twist angles (<12 degrees), the differences in torque expression between wires were not statistically significant. At twist angles over 24 degrees, stainless steel wire yielded 1.5 to 2 times the torque expression of TMA and 2.5 to 3 times that of nickel titanium (NiTi). At high angles of torsion (over 40 degrees) with a stiff wire material, loss of linear torque expression sometimes occurred. Stainless steel has the largest torque expression, followed by TMA and then NiTi.
Van den Bulck, Jan
2007-01-01
Objective: To assess the prevalence of the use of mobile phones by adolescents after lights out and its relationship to tiredness levels after one year. Design: Prospective cohort study with self-reports and follow up questionnaire after one year. Setting: Second- and fifth-year secondary school children in 15 schools in Flanders, Belgium. Participants: 1656 school children; 52.1% boys. Average age was 13.7 years (SD: 0.68) in the youngest group and 16.9 years (SD: 0.83) in the oldest group at baseline. Main outcome measures: Self-reported tiredness. Results: Only 38% of the subjects never used their mobile phone after lights out. Multinomial logistic regression showed that using the mobile phone less than once a month increased the odds of being very tired one year later by 1.8 (95% CI 1.2 – 2.8). Those who used it less than once a week were 2.2 times more likely to be very tired (95% CI 1.4 – 3.5). Using it about once a week increased the odds by 3.3 (95% CI 1.9 – 5.7) and those who used it more than once a week were 5.1 times more likely to be very tired (95% CI 2.5 – 10.4). Overall 35% of the cases of being very tired were attributed to the use of the mobile phone. Use of the phone right after lights out increased the odds of being very tired by 2.2 (95% CI 1.4 – 3.4); between 00:00 and 03:00 the odds were 3.9 times higher (95% CI 2.1 – 7.1), and in those who used it at any time of the night the odds were 3.3 times higher (95% CI 1.8 – 6.0). Conclusion: Mobile phone use after lights out is very prevalent among adolescents. Its use is related to increased levels of tiredness. There is no safe dose and no safe time for using the mobile phone for text messaging or for calling after lights out. Citation: Van den Bulck J. Adolescent use of mobile phones for calling and for sending text messages after lights out: results from a prospective cohort study with a one-year follow-up. SLEEP 2007;30(9):1220-1223. PMID:17910394
White Nail Radio Transmitter: Billion Dollar Savings through Energy Efficiency
2011-05-10
increase efficiency and reduce overall energy consumption ashore by 50 percent CNO, Navy Energy Vision, P 10 White Nail Vision Your Cell Phone Cell...Estimated Total Number of transmitters 3,000,000 Estimated total power saved Watt 1,250,000,000 Cell Phone Transmitter Efficiency 1.25 Gigawatts saved...Greenhouse Gas Power 4 1 Energy Navy Use 7.3 Billion kWh White Nail Cell Phone Savings 11 Billion kWh One and a half times!!! Saves the output of four of
Brannelly, Laura A; Roberts, Alexandra A; Skerratt, Lee F; Berger, Lee
2018-05-16
Amphibians are experiencing a great loss in biodiversity globally and one of the major causes is the infectious disease chytridiomycosis. This disease is caused by the fungal pathogen Batrachochytrium dendrobatidis (Bd), which infects and disrupts frog epidermis; however, pathological changes have not been explicitly characterized. Apoptosis (programmed cell death) can be used by pathogens to damage host tissue, but can also be a host mechanism of disease resistance for pathogen removal. In this study, we quantify epidermal cell death of infected and uninfected animals using two different assays: terminal transferase-mediated dUTP nick end-labelling (TUNEL), and caspase 3/7. Using ventral, dorsal, and thigh skin tissue in the TUNEL assay, we observe cell death in the epidermal cells in situ of clinically infected animals and compare cell death with uninfected animals using fluorescent microscopy. In order to determine how apoptosis levels in the epidermis change over the course of infection we remove toe-tip samples fortnightly over an 8-week period, and use a caspase 3/7 assay with extracted proteins to quantify activity within the samples. We then correlate caspase 3/7 activity with infection load. The TUNEL assay is useful for localization of cell death in situ, but is expensive and time intensive per sample. The caspase 3/7 assay is efficient for large sample sizes and time course experiments. However, because frog toe tip biopsies are small there is limited extract available for sample standardization via protein quantification methods, such as the Bradford assay. Therefore, we suggest estimating skin surface area through photographic analysis of toe biopsies to avoid consuming extracts during sample standardization.
A study on electromigration-inducing intergranular fracture of fine silver alloy wires
NASA Astrophysics Data System (ADS)
Hsueh, Hao-Wen; Hung, Fei-Yi; Lui, Truan-Sheng
2017-01-01
In this study, Pd-coated Cu, Ag (purity = 4 N), and Ag alloy (Ag-8Au-3Pd) wires were employed to measure the tensile properties during current stressing using the so-called dynamic current tensile (DCT) test. Both the tensile strength and elongation of the wires decreased dramatically in the DCT test, particularly of the Ag-based wires, and the fracture morphology of the Cu-based and Ag-based wires was ductile fracture and intergranular fracture, respectively. Compared to the Cu-based wires, electromigration occurred more easily in the Ag-based wires, and it always generated voids and cracks at the grain boundaries; therefore, the fracture morphology of the Ag-based wires was intergranular fracture owing to the weakened grain boundary. Further, the results indicated that the Ag-based wires could not carry a higher current density than the Cu-based wires, primarily because their extremely low strength and elongation in current stressing might cause serious reliability problems.
Use of the iPhone for Cobb angle measurement in scoliosis.
Shaw, Matthew; Adam, Clayton J; Izatt, Maree T; Licina, Paul; Askin, Geoffrey N
2012-06-01
The Cobb technique is the universally accepted method for measuring the severity of spinal deformities. Traditionally, Cobb angles have been measured using protractor and pencil on hardcopy radiographic films. The new generation of mobile 'smartphones' make accurate angle measurement possible using an integrated accelerometer, providing a potentially useful clinical tool for assessing Cobb angles. The purpose of this study was to compare Cobb angle measurements performed using a smartphone and traditional protractor in a series of 20 adolescent idiopathic scoliosis patients. Seven observers measured major Cobb angles on 20 pre-operative postero-anterior radiographs of Adolescent Idiopathic Scoliosis patients with both a standard protractor and using an Apple iPhone. Five of the observers repeated the measurements at least a week after the original measurements. The mean absolute difference between pairs of smartphone/protractor measurements was 2.1°, with a small (1°) bias toward lower Cobb angles with the iPhone. 95% confidence intervals for intra-observer variability were ±3.3° for the protractor and ±3.9° for the iPhone. 95% confidence intervals for inter-observer variability were ±8.3° for the iPhone and ±7.1° for the protractor. Both of these confidence intervals were within the range of previously published Cobb measurement studies. We conclude that the iPhone is an equivalent Cobb measurement tool to the manual protractor, and measurement times are about 15% less. The widespread availability of inclinometer-equipped mobile phones and the ability to store measurements in later versions of the angle measurement software may make these new technologies attractive for clinical measurement applications.
A new infusion pathway intactness monitoring system.
Ogawa, Hidekuni; Yonezawa, Yoshiharu; Maki, Hiromichi; Ninomiya, Ishio; Sata, Koji; Hamada, Shingo; Caldwell, W Morton
2006-01-01
A new infusion pathway monitoring system has been developed for hospital and home use. The system consists of linear integrated circuits and a low-power 8-bit single chip microcomputer which constantly monitors the infusion pathway intactness. An AC (alternating current) voltage is induced on the patient's body by electrostatic coupling from the normal 100 volt, 60 Hz AC power line wiring field in the patient's room. The induced AC voltage can be recorded by a main electrode wrapped around the infusion polyvinyl chloride tube. A reference electrode is wrapped on the electrode to monitor the AC voltage around the main electrode. If the injection needle or infusion tube becomes detached, then the system detects changes in the induced AC voltages and alerts the nursing station, via the nurse call system or PHS (personal handy phone system).
Sage, Cindy; Burgio, Ernesto
2018-01-01
Mobile phones and other wireless devices that produce electromagnetic fields (EMF) and pulsed radiofrequency radiation (RFR) are widely documented to cause potentially harmful health impacts that can be detrimental to young people. New epigenetic studies are profiled in this review to account for some neurodevelopmental and neurobehavioral changes due to exposure to wireless technologies. Symptoms of retarded memory, learning, cognition, attention, and behavioral problems have been reported in numerous studies and are similarly manifested in autism and attention deficit hyperactivity disorders, as a result of EMF and RFR exposures where both epigenetic drivers and genetic (DNA) damage are likely contributors. Technology benefits can be realized by adopting wired devices for education to avoid health risk and promote academic achievement. © 2017 The Authors. Child Development © 2017 Society for Research in Child Development, Inc.
Effect of Electromagnetic Wave on Bone Healing in Fixed and Unfixed Conditions.
Onger, Mehmet Emin; Göçer, Hasan; Çirakli, Alper; Büyükceran, Ismail; Kiliç, Mesut; Kaplan, Süleyman
2016-09-01
Mobile phones have come into daily life and are now one of the most frequently used devices for communication. The aim of this study was to evaluate possible effect of electromagnetic wave (EMW) with and without fixation material on bone healing.Forty male rats were exposed to fracture on tibia bone and were randomly divided into 4 groups as E(+)K(+), E(+)K(-), E(-)K(+), and E(-)K(-) where E(+) means EMW exposure and K(+) means Kirschner wire fixation. At the end of study tibia samples were taken from all the groups for the quantitative evaluation of regeneration.Significant difference was found between Group E(+)K(+) and E(-)K(+) in terms of both new bone and capillary volume.Electromagnetic wave may be harmful for bone healing with fixation whereas it has no same effect on bone regeneration without fixation.
Phone use while driving: results from an observational survey.
Wundersitz, L N
2014-01-01
The aim of this study was to quantify the level of handheld phone use when driving in South Australia. The study also sought to investigate any driver, site, and vehicle characteristics associated with handheld phone use to inform countermeasure development and publicity campaigns. An on-road observational survey of handheld phone use was undertaken as part of a larger restraint use survey. The survey was conducted at 61 sites in metropolitan Adelaide and rural regions within South Australia on weekdays and a weekend in 2009. A total of 64 (0.6%) of the 11,524 drivers observed during the survey were using handheld phones. Handheld phone usage rates ranged from 0.8 percent in metropolitan Adelaide to 0.3 percent in the rural region of The Riverland. Of all driver, site, and vehicle characteristics examined, the only statistically significant difference in handheld phone usage was for the number of vehicle occupants. The odds of a driver using a handheld phone while traveling alone was over 4 times higher than for a driver traveling with passengers. The level of handheld phone use among drivers in South Australia appears to be low relative to other jurisdictions. The level of enforcement activity and severity of penalties do not offer a clear explanation for the higher levels of compliance with phone laws. Given the rate of increase in phone technology, it is important to conduct regular roadside surveys of phone use among drivers to monitor trends in usage over time.
Mobile Phone Health Applications for the Federal Sector.
Burrows, Christin S; Weigel, Fred K
2016-01-01
As the US healthcare system moves toward a mobile care model, mobile phones will play a significant role in the future of healthcare delivery. Today, 90% of American adults own a mobile phone and 64% own a smartphone, yet many healthcare organizations are only beginning to explore the opportunities in which mobile phones can improve and streamline care. After searching Google Scholar, the Association for Computing Machinery Database, and PubMed for articles related to mobile phone health applications and cell phone text message health, we selected articles and studies related to the application of mobile phones in healthcare. From our initial review, we identified the potential application areas and continued to refine our search, identifying a total of 55 articles for additional review and analysis. From the literature, we identified 3 main themes for mobile phone implementation in improving healthcare: primary, preventive, and population health. We recommend federal health leaders pursue the value and potential in these areas; not only because 90% of Americans already own mobile phones, but also because mobile phone integration can provide substantial access and potential cost savings. From the positive findings of multiple studies in primary, preventive, and population health, we propose a 5-year federal implementation plan to integrate mobile phone capabilities into federal healthcare delivery. Our proposal has the potential to improve access, reduce costs, and increase patient satisfaction, therefore changing the way the federal sector delivers healthcare by 2021.
Liu, Ying; Ren, Wen; Qiu, Yan; Liu, Juanjuan; Yin, Pei; Ren, Jingjing
2016-05-24
Mobile phones and mobile phone apps have expanded new forms of health professionals' work. There are many studies on the use of mobile phone apps for different specialists. However, there are no studies on the current use of mobile phone apps among general practitioners (GPs). The objective of the study was to investigate the extent to which GPs own smartphones with apps and use them to aid their clinical activities. A questionnaire survey of GPs was undertaken in Hangzhou, Eastern China. Data probing GPs' current use of medical apps in their clinical activities and factors influencing app use were collected and analyzed 125 GPs participated in the survey. 90.4% of GPs owned a mobile phone, with 48.7% owning an iPhone and 47.8% owning an Android phone. Most mobile phone owners had 1-3 medical-related apps, with very few owning more than 4. There was no difference in number of apps between iPhone and Android owners (χ(2)=1.388, P=0.846). 36% of GPs reported using medical-related apps on a daily basis. The majority of doctors reported using apps to aid clinical activities less than 30 minutes per day. A high level of mobile phone ownership and usage among GPs was found in this study, but few people chose medical-related apps to support their clinical practice.
Mobile phone use while cycling: incidence and effects on behaviour and safety.
de Waard, Dick; Schepers, Paul; Ormel, Wieke; Brookhuis, Karel
2010-01-01
The effects of mobile phone use on cycling behaviour were studied. In study 1, the prevalence of mobile phone use while cycling was assessed. In Groningen 2.2% of cyclists were observed talking on their phone and 0.6% were text messaging or entering a phone number. In study 2, accident-involved cyclists responded to a questionnaire. Only 0.5% stated that they were using their phone at the time of the accident. In study 3, participants used a phone while cycling. The content of the conversation was manipulated and participants also had to enter a text message. Data were compared with just cycling and cycling while listening to music. Telephoning coincided with reduced speed, reduced peripheral vision performance and increased risk and mental effort ratings. Text messaging had the largest negative impact on cycling performance. Higher mental workload and lower speed may account for the relatively low number of people calling involved in accidents. STATEMENT OF RELEVANCE: Although perhaps mainly restricted to flat countries with a large proportion of cyclists, mobile phone use while cycling has increased and may be a threat to traffic safety, similar to phone use while driving a car. In this study, the extent of the problem was assessed by observing the proportion of cyclists using mobile phones, sending questionnaires to accident-involved cyclists and an experimental study was conducted on the effects of mobile phone use while cycling.
Bhoonderowa, A; Gookool, S; Biranjia-Hurdoyal, S D
2014-10-01
Mobile phones have become indispensable accessories in today's life. However, they might act as fomites as they have travelled with their owner to places such as toilets, hospitals and kitchens which are loaded with microorganisms. A cross-sectional study was carried out to isolate and identify bacteria from mobile phones of volunteers in the community. A total of 192 mobile phones from 102 males and 90 females were swabbed and cultured. The bacteria were identified by gram staining and conventional biochemical tests. A total of 176 mobile phones (91.7 %) showed bacterial contamination. Coagulase negative Staphylococcus was the most prevalent (69.3 %) followed by Micrococci (51.8 %), Klebsiella (1.5 %) and Pseudomonas (1 %). The mean colony forming units was higher among females than males (p < 0.05; 95 % CI 0.021-0.365) and higher on mobile phones which were kept in bags than in pockets (p < 0.05; 95 % CI 0.019-0.369). Furthermore, the use of phone cover was found to reduce microbial growth (OR 4.2; 95 % CI 1.423-12.39; p < 0.05). Significant associations were also found between bacterial growth and female participants, agricultural workers, mobile phones older than 6 months and sharing of mobile phones (p < 0.05). Mobile phones from the community carry potential pathogens. Cleaning of mobile phones should be encouraged and should be preferably stored in pockets or carry cases.
Nonlinear metamaterials for electromagnetic energy harvesting (Conference Presentation)
NASA Astrophysics Data System (ADS)
Oumbe Tekam, Gabin Thibaut; Ginis, Vincent; Seetharamdoo, Divitha; Danckaert, Jan
2016-09-01
Surrounded by electromagnetic radiation coming from wireless power transfer to consumer devices such as mobile phones, computers and television, our society is facing the scientific and technological challenge to recover energy that is otherwise lost to the environment. Energy harvesting is an emerging field of research focused on this largely unsolved problem, especially in the microwave regime. Metamaterials provide a very promising platform to meet this purpose. These artificial materials are made from subwavelength building blocks, and can be designed by resonate at particular frequencies, depending on their shape, geometry, size, and orientation. In this work, we show that an efficient electromagnetic energy harvester can be design by inserting a nonlinear element directly within the metamaterial unit cell, leading to the conversion of RF input power to DC charge accumulation. The electromagnetic energy harvester operating at microwave frequencies is built from a cut-wire metasurface, which operates as a quasistatic electric dipole resonator. Using the equivalent electrical circuit, we design the parameters to tune the resonance frequency of the harvester at the desired frequency, and we compare these results with numerical simulations. Finally, we discuss the efficiency of our metamaterial energy harvesters. This work potentially offers a variety of applications, for example in the telecommunications industry to charge phones, in robotics to power microrobots, and also in medicine to advance pacemakers or health monitoring sensors.
Perdigão, João Paulo Veloso; Lustosa, Romulo Maciel; Tolentino, Elen de Souza; Iwaki Filho, Liogi; Iwaki, Lilian Cristina Vessoni
2016-01-01
Revalence of impaction of mandibular permanent second molars is between 0.06 and 2.3 percent. In order to reduce treatment time and complications associated with tooth impaction, intervention should take place once the problem is detected. The usual treatment options consists of surgical exposure, luxation of the impacted tooth, extraction of adjacent third molar, orthodontic treatment, and uprighting with brass wires or mini-screws. The present paper reports a case of bilateral impaction of mandibular permanent second molars ' (MM2s) treated with extraction of the mandibular third molars (MM3s) and surgical-orthodontic uprighting with the brass wire technique. The MM3s were removed, and the impacted MM2s were surgically exposed. Brass wire was placed apicaly to the mesial of the MM2 from the lingual tissue out toward the buccal. The lingual end of the wire was bent over the area of contact and twisted with the buccal end Monthly wire tightening gradually moved the MM2s distally and towards the occlusal plane. Uprighting was achieved in 4-5 months, with discrete pain caused by activation of the wire. This technique proved to be a simple, low-cost, and quick treatment option for uprighting impacted mandibular permanent second molars.
Navani-Vazirani, Sonia; Solomon, Davidson; Gopalakrishnan; Heylen, Elsa; Srikrishnan, Aylur Kailasom; Vasudevan, Canjeevaram K; Ekstrand, Maria L
2015-01-01
The aim of this study was to examine female sex workers' solicitation of clients using mobile phones and the association between this and condom use with clients. Cross-sectional data were utilised to address the study's aim, drawing on data collected from female sex workers in Calicut, Kerala, and Chirala, Andhra Pradesh. Use of mobile phone solicitation was reported by 46.3% (n = 255) of Kerala participants and 78.7% (n = 464) of those in Andhra Pradesh. Kerala participants reporting exclusive solicitation using mobile phones demonstrated 1.67 times higher odds (95% CI: 1.01-2.79) of inconsistent condom use than those reporting non-use of mobile phones for solicitation. However, those reporting exclusive solicitation through mobile phones in Andhra Pradesh reported lower odds of inconsistent condom use (OR: 0.03; 95% CI: 0.01-0.26) than those not using mobile phones for solicitation. Findings indicate that solicitation of clients using mobile phones facilitates or hampers consistency in condom use with clients depending on the context, and how mobile phones are incorporated into solicitation practices. Variations in sex work environments, including economic dependence on sex work or lack thereof may partially account for the different effects found.
Navani-Vazirani, S; Solomon, D; Krishnan, G; Heylen, E; Srikrishnan, AK; Vasudevan, CK; Ekstrand, ML
2014-01-01
The aim of this study was to examine female sex workers’ solicitation of clients using mobile phones and the association between this and condom use with clients. Cross-sectional data were utilised to address the study's aim, drawing on data collected from female sex workers in Calicut, Kerala and Chirala, Andhra Pradesh. Use of mobile phone solicitation was reported by 46.3% (n = 255) of Kerala participants and 78.7% (n = 464) of those in Andhra Pradesh. Kerala participants reporting exclusive solicitation using mobile phones demonstrated 1.67 times higher odds (95% CI: 1.01–2.79) of inconsistent condom use than those reporting non-use of mobile phones for solicitation. However, those reporting exclusive solicitation through mobile phones in Andhra Pradesh reported lower odds of inconsistent condom use (OR: 0.03; 95% CI: 0.01–0.26) than those not using mobile phones for solicitation. Findings indicate that solicitation of clients using mobile phones facilitates or hampers consistency in condom use with clients depending on the context, and how mobile phones are incorporated into solicitation practices. Variations in sex work environments, including economic dependence on sex work or lack thereof may partially account for the different effects found. PMID:25301669
Modelling and assessment of the electric field strength caused by mobile phone to the human head.
Buckus, Raimondas; Strukcinskiene, Birute; Raistenskis, Juozas; Stukas, Rimantas
2016-06-01
Electromagnetic field exposure is the one of the most important physical agents that actively affects live organisms and environment. Active use of mobile phones influences the increase of electromagnetic field radiation. The aim of the study was to measure and assess the electric field strength caused by mobile phones to the human head. In this paper the software "COMSOL Multiphysics" was used to establish the electric field strength created by mobile phones around the head. The second generation (2G) Global System for Mobile (GSM) phones that operate in the frequency band of 900 MHz and reach the power of 2 W have a stronger electric field than (2G) GSM mobile phones that operate in the higher frequency band of 1,800 MHz and reach the power up to 1 W during conversation. The third generation of (3G) UMTS smart phones that effectively use high (2,100 MHz) radio frequency band emit the smallest electric field strength values during conversation. The highest electric field strength created by mobile phones is around the ear, i.e. the mobile phone location. The strength of mobile phone electric field on the phantom head decreases exponentially while moving sidewards from the center of the effect zone (the ear), and constitutes 1-12% of the artificial head's surface. The highest electric field strength values of mobile phones are associated with their higher power, bigger specific energy absorption rate (SAR) and lower frequency of mobile phone. The stronger electric field emitted by the more powerful mobile phones takes a higher percentage of the head surface. The highest electric field strength created by mobile phones is distributed over the user's ear.
Comparison of three different orthodontic wires for bonded lingual retainer fabrication
Uysal, Tancan; Gul, Nisa; Alan, Melike Busra; Ramoglu, Sabri Ilhan
2012-01-01
Objective We evaluated the detachment force, amount of deformation, fracture mode, and pull-out force of 3 different wires used for bonded lingual retainer fabrication. Methods We tested 0.0215-inch five-stranded wire (PentaOne, Masel; group I), 0.016 × 0.022-inch dead-soft eight-braided wire (Bond-A-Braid, Reliance; group II), and 0.0195-inch dead-soft coaxial wire (Respond, Ormco; group III). To test detachment force, deformation, and fracture mode, we embedded 94 lower incisor teeth in acrylic blocks in pairs. Retainer wires were bonded to the teeth and vertically directed force was applied to the wire. To test pull-out force, wires were embedded in composite that was placed in a hole at the center of an acrylic block. Tensile force was applied along the long axis of the wire. Results Detachment force and mode of fracture were not different between groups. Deformation was significantly higher in groups II and III than in group I (p < 0.001). Mean pull-out force was significantly higher for group I compared to groups II and III (p < 0.001). Conclusions Detachment force and fracture mode were similar for all wires, but greater deformations were seen in dead-soft wires. Wire pull-out force was significantly higher for five-stranded coaxial wire than for the other wires tested. Five-stranded coaxial wires are suggested for use in bonded lingual retainers. PMID:23112930
Method of making V.sub.3 Ga superconductors
Dew-Hughes, David
1980-01-01
An improved method for producing a vanadium-gallium superconductor wire having aluminum as a component thereof is disclosed, said wire being encased in a gallium bearing copper sheath. The superconductors disclosed herein may be fabricated under normal atmospheres and room temperatures by forming a tubular shaped billet having a core composed of an alloy of vanadium and aluminum and an outer sheath composed of an alloy of copper, gallium and aluminum. Thereafter the entire billet is swage reduced to form a wire therefrom and heat treated to form a layer of V.sub.3 Ga in the interior of the wire.
Designing and testing a wearable, wireless fNIRS patch.
Abtahi, Mohammadreza; Cay, Gozde; Saikia, Manob Jyoti; Mankodiya, Kunal
2016-08-01
Optical brain monitoring using near infrared (NIR) light has got a lot of attention in order to study the complexity of the brain due to several advantages as oppose to other methods such as EEG, fMRI and PET. There are a few commercially available functional NIR spectroscopy (fNIRS) brain monitoring systems, but they are still non-wearable and pose difficulties in scanning the brain while the participants are in motion. In this work, we present our endeavors to design and test a low-cost, wireless fNIRS patch using NIR light sources at wavelengths of 770 and 830nm, photodetectors and a microcontroller to trigger the light sources, read photodetector's output and transfer data wirelessly (via Bluetooth) to a smart-phone. The patch is essentially a 3-D printed wearable system, recording and displaying the brain hemodynamic responses on smartphone, also eliminates the need for complicated wiring of the electrodes. We have performed rigorous lab experiments on the presented system for its functionality. In a proof of concept experiment, the patch detected the NIR absorption on the arm. Another experiment revealed that the patch's battery could last up to several hours with continuous fNIRS recording with and without wireless data transfer.
49 CFR Appendix D to Part 40 - Report Format: Split Specimen Failure To Reconfirm
Code of Federal Regulations, 2010 CFR
2010-10-01
.... The following items are required on each report: 1. MRO name, address, phone number, and fax number. 2. Collection site name, address, and phone number. 3. Date of collection. 4. Specimen I.D. number. 5. Laboratory accession number. 6. Primary specimen laboratory name, address, and phone number. 7. Date result...
A Study in Kuwait of Health Risks Associated with Using Cell Phones
ERIC Educational Resources Information Center
Al-Khamees, Nedaa
2007-01-01
Previous studies have suggested a link between cell phone use and various symptoms. Analysis of 3,274 completed questionnaires from throughout Kuwait show a significant effect of exposure to cell phones for burning sensation on the ear, temporal pain, pain in the back of the head, auricular pain, noises in the ear, ear numbness, heartbeat…
49 CFR Appendix D to Part 40 - Report Format: Split Specimen Failure To Reconfirm
Code of Federal Regulations, 2014 CFR
2014-10-01
.... The following items are required on each report: 1. MRO name, address, phone number, and fax number. 2. Collection site name, address, and phone number. 3. Date of collection. 4. Specimen I.D. number. 5. Laboratory accession number. 6. Primary specimen laboratory name, address, and phone number. 7. Date result...
36 CFR 1237.3 - What standards are incorporated by reference in this part?
Code of Federal Regulations, 2011 CFR
2011-07-01
... Information Center (NWCCA), Room 2380, 8601 Adelphi Road, College Park, MD 20740-6001, phone number (301) 837... and Records Administration, 8601 Adelphi Road, College Park, MD 20740-6001, phone number (301) 837... Standards Institute, 25 West 43rd St., 4th Floor, New York, NY 10036, phone number (212) 642-4900, or online...
49 CFR Appendix D to Part 40 - Report Format: Split Specimen Failure To Reconfirm
Code of Federal Regulations, 2013 CFR
2013-10-01
.... The following items are required on each report: 1. MRO name, address, phone number, and fax number. 2. Collection site name, address, and phone number. 3. Date of collection. 4. Specimen I.D. number. 5. Laboratory accession number. 6. Primary specimen laboratory name, address, and phone number. 7. Date result...
49 CFR Appendix D to Part 40 - Report Format: Split Specimen Failure To Reconfirm
Code of Federal Regulations, 2012 CFR
2012-10-01
.... The following items are required on each report: 1. MRO name, address, phone number, and fax number. 2. Collection site name, address, and phone number. 3. Date of collection. 4. Specimen I.D. number. 5. Laboratory accession number. 6. Primary specimen laboratory name, address, and phone number. 7. Date result...
36 CFR 1237.3 - What standards are incorporated by reference in this part?
Code of Federal Regulations, 2014 CFR
2014-07-01
... Information Center (NWCCA), Room 2380, 8601 Adelphi Road, College Park, MD 20740-6001, phone number (301) 837... and Records Administration, 8601 Adelphi Road, College Park, MD 20740-6001, phone number (301) 837... Standards Institute, 25 West 43rd St., 4th Floor, New York, NY 10036, phone number (212) 642-4900, or online...
36 CFR 1237.3 - What standards are incorporated by reference in this part?
Code of Federal Regulations, 2012 CFR
2012-07-01
... Information Center (NWCCA), Room 2380, 8601 Adelphi Road, College Park, MD 20740-6001, phone number (301) 837... and Records Administration, 8601 Adelphi Road, College Park, MD 20740-6001, phone number (301) 837... Standards Institute, 25 West 43rd St., 4th Floor, New York, NY 10036, phone number (212) 642-4900, or online...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-08
... Phones and Tablet Computers, and Components Thereof Institution of Investigation AGENCY: U.S... computers, and components thereof by reason of infringement of certain claims of U.S. Patent No. 5,570,369... mobile phones and tablet computers, and components thereof that infringe one or more of claims 1-3 and 5...
Emerging aspects of mobile phone use.
Samkange-Zeeb, F; Blettner, M
2009-01-01
The mobile phone is a modern-day invention, which has managed to reach many parts of the world enabling telecommunications across areas where it was not possible before. Although these devices have proved to be life saving in certain circumstances (e.g., after accidents) and helped improve the quality of life in some sectors, concerns continue to be raised about potential adverse health impacts associated with their use. These range from cancer and cognitive deficiencies to subjective effects, such as a feeling of warmth around the ear used, headache and fatigue. We provide an overview of the concerns raised and summarise what is known about them. We conducted a literature search in Pubmed/Medline to identify published papers on health effects of mobile phones, and an intensive search on the Internet to collect data on the global use of mobile phones. In the year 2000, there were an estimated 500 million mobile phone users worldwide. Today, there are about 3.3 billion users. The use of mobile phones among young children and adolescents is also increasing. Health-risk research has mainly focused on adults and on a single outcome, brain tumours. No significant relationship has been established between mobile phone use and the incidence or growth of brain tumours. Other research indicates emerging concerns, including hearing problems and self-reported health symptoms, such as tiredness, stress, headache, anxiety, concentration difficulties and sleep disturbances, but results remain inconclusive. Currently, there is little epidemiological evidence indicating that the use of mobile phones causes adverse health effects.
Emerging aspects of mobile phone use
Samkange-Zeeb, F; Blettner, M
2009-01-01
The mobile phone is a modern-day invention, which has managed to reach many parts of the world enabling telecommunications across areas where it was not possible before. Although these devices have proved to be life saving in certain circumstances (e.g., after accidents) and helped improve the quality of life in some sectors, concerns continue to be raised about potential adverse health impacts associated with their use. These range from cancer and cognitive deficiencies to subjective effects, such as a feeling of warmth around the ear used, headache and fatigue. We provide an overview of the concerns raised and summarise what is known about them. We conducted a literature search in Pubmed/Medline to identify published papers on health effects of mobile phones, and an intensive search on the Internet to collect data on the global use of mobile phones. In the year 2000, there were an estimated 500 million mobile phone users worldwide. Today, there are about 3.3 billion users. The use of mobile phones among young children and adolescents is also increasing. Health-risk research has mainly focused on adults and on a single outcome, brain tumours. No significant relationship has been established between mobile phone use and the incidence or growth of brain tumours. Other research indicates emerging concerns, including hearing problems and self-reported health symptoms, such as tiredness, stress, headache, anxiety, concentration difficulties and sleep disturbances, but results remain inconclusive. Currently, there is little epidemiological evidence indicating that the use of mobile phones causes adverse health effects. PMID:22460286
Cheptinga, Philip; Rusyniak, Daniel E.
2015-01-01
Objective. Mobile phones have been successfully used for Emergency Department (ED) patient follow-up in developed countries. Mobile phones are widely available in developing countries and may offer a similar potential for follow-up and continued care of ED patients in low and middle-income countries. The goal of this study was to determine the percentage of families with mobile phones presenting to a pediatric ED in western Kenya and rate of response to a follow-up phone call after discharge. Methods. A prospective, cross-sectional observational study of children presenting to the emergency department of a government referral hospital in Eldoret, Kenya was performed. Documentation of mobile phone access, including phone number, was recorded. If families had access, consent was obtained and families were contacted 7 days after discharge for follow-up. Results. Of 788 families, 704 (89.3%) had mobile phone access. Of those families discharged from the ED, successful follow-up was made in 83.6% of cases. Conclusions. Mobile phones are an available technology for follow-up of patients discharged from a pediatric emergency department in resource-limited western Kenya. PMID:25780757
House, Darlene R; Cheptinga, Philip; Rusyniak, Daniel E
2015-01-01
Objective. Mobile phones have been successfully used for Emergency Department (ED) patient follow-up in developed countries. Mobile phones are widely available in developing countries and may offer a similar potential for follow-up and continued care of ED patients in low and middle-income countries. The goal of this study was to determine the percentage of families with mobile phones presenting to a pediatric ED in western Kenya and rate of response to a follow-up phone call after discharge. Methods. A prospective, cross-sectional observational study of children presenting to the emergency department of a government referral hospital in Eldoret, Kenya was performed. Documentation of mobile phone access, including phone number, was recorded. If families had access, consent was obtained and families were contacted 7 days after discharge for follow-up. Results. Of 788 families, 704 (89.3%) had mobile phone access. Of those families discharged from the ED, successful follow-up was made in 83.6% of cases. Conclusions. Mobile phones are an available technology for follow-up of patients discharged from a pediatric emergency department in resource-limited western Kenya.
2013-01-01
Background Use of mobile phones has rapidly risen among adolescents despite a lack of scientific certainty on their health risks. Risk perception is an important determinant of behavior, and studies on adolescents’ risk perceptions of mobile phones or base stations are very scarce. This study aims to evaluate high school students’ risk perceptions on mobile phones and base stations, their trust to authorities, their opinions regarding incivility while using mobile phones and to assess associated factors. Methods For this cross-sectional study, 2530 students were chosen with stratified cluster sampling among 20,493 high school students studying in Bornova district of Izmir, Turkey, among whom 2240 (88.5%) participated. Risk perceptions and opinions were questioned with a 5-point Likert scale for 24 statements grouped under four dimensions. The mean responses to the four dimensions were categorized as <3.5 (low) and ≥3.5 (high) and the determinants were analyzed with logistic regression. Results Mean risk perception scores for the mobile phone, base station, trust to authority and incivility dimensions were 3.69 ± 0.89, 4.34 ± 0.78, 3.77 ± 0.93, 3.16 ± 0.93 and the prevalence of high risk perception was 65.1%, 86.7%, 66.2%, 39.7%, respectively. In the mobile phone dimension; students attending industrial technical high school had lower risk perceptions while female students, lower mothers’ education groups and students not using mobile phones (OR = 2.82, 95% CI = 1.80-4.40) had higher risk perceptions. In the base station dimension girls had higher risk perceptions (OR = 1.68, 95% CI = 1.20-2.37). Girls and students attending industrial technical high school had significantly lower risk perception however 11-12th grade group perceived the risk higher (OR = 1.45 95% CI = 1.15-1.84) in the trust to authority dimension. For the incivility dimension, female students (OR = 1.44, 95% CI = 1.14-1.82), illiterate/only literate mothers (OR = 1.79, 95% CI = 1.04-2.75) and students not using mobile phones (OR = 2.50, 95% CI = 1.62-3.87) perceived higher risk. Conclusions Understanding the effects of these determinants might aid in developing more effective educational interventions to specific subgroups on this topic. As debates on the health consequences of electromagnetic fields continue, it would be cautious to approach this issue with a preventive perspective. Efforts should be made to equalize the varying level of knowledge and to ensure that students are informed accurately. PMID:23351724
Hassoy, Hur; Durusoy, Raika; Karababa, Ali Osman
2013-01-25
Use of mobile phones has rapidly risen among adolescents despite a lack of scientific certainty on their health risks. Risk perception is an important determinant of behavior, and studies on adolescents' risk perceptions of mobile phones or base stations are very scarce. This study aims to evaluate high school students' risk perceptions on mobile phones and base stations, their trust to authorities, their opinions regarding incivility while using mobile phones and to assess associated factors. For this cross-sectional study, 2530 students were chosen with stratified cluster sampling among 20,493 high school students studying in Bornova district of Izmir, Turkey, among whom 2240 (88.5%) participated. Risk perceptions and opinions were questioned with a 5-point Likert scale for 24 statements grouped under four dimensions. The mean responses to the four dimensions were categorized as <3.5 (low) and ≥3.5 (high) and the determinants were analyzed with logistic regression. Mean risk perception scores for the mobile phone, base station, trust to authority and incivility dimensions were 3.69 ± 0.89, 4.34 ± 0.78, 3.77 ± 0.93, 3.16 ± 0.93 and the prevalence of high risk perception was 65.1%, 86.7%, 66.2%, 39.7%, respectively. In the mobile phone dimension; students attending industrial technical high school had lower risk perceptions while female students, lower mothers' education groups and students not using mobile phones (OR = 2.82, 95% CI = 1.80-4.40) had higher risk perceptions. In the base station dimension girls had higher risk perceptions (OR = 1.68, 95% CI = 1.20-2.37). Girls and students attending industrial technical high school had significantly lower risk perception however 11-12th grade group perceived the risk higher (OR = 1.45 95% CI = 1.15-1.84) in the trust to authority dimension. For the incivility dimension, female students (OR = 1.44, 95% CI = 1.14-1.82), illiterate/only literate mothers (OR = 1.79, 95% CI = 1.04-2.75) and students not using mobile phones (OR = 2.50, 95% CI = 1.62-3.87) perceived higher risk. Understanding the effects of these determinants might aid in developing more effective educational interventions to specific subgroups on this topic. As debates on the health consequences of electromagnetic fields continue, it would be cautious to approach this issue with a preventive perspective. Efforts should be made to equalize the varying level of knowledge and to ensure that students are informed accurately.
Karbowski, Jan
2015-01-01
The structure and quantitative composition of the cerebral cortex are interrelated with its computational capacity. Empirical data analyzed here indicate a certain hierarchy in local cortical composition. Specifically, neural wire, i.e., axons and dendrites take each about 1/3 of cortical space, spines and glia/astrocytes occupy each about (1/3)2, and capillaries around (1/3)4. Moreover, data analysis across species reveals that these fractions are roughly brain size independent, which suggests that they could be in some sense optimal and thus important for brain function. Is there any principle that sets them in this invariant way? This study first builds a model of local circuit in which neural wire, spines, astrocytes, and capillaries are mutually coupled elements and are treated within a single mathematical framework. Next, various forms of wire minimization rule (wire length, surface area, volume, or conduction delays) are analyzed, of which, only minimization of wire volume provides realistic results that are very close to the empirical cortical fractions. As an alternative, a new principle called “spine economy maximization” is proposed and investigated, which is associated with maximization of spine proportion in the cortex per spine size that yields equally good but more robust results. Additionally, a combination of wire cost and spine economy notions is considered as a meta-principle, and it is found that this proposition gives only marginally better results than either pure wire volume minimization or pure spine economy maximization, but only if spine economy component dominates. However, such a combined meta-principle yields much better results than the constraints related solely to minimization of wire length, wire surface area, and conduction delays. Interestingly, the type of spine size distribution also plays a role, and better agreement with the data is achieved for distributions with long tails. In sum, these results suggest that for the efficiency of local circuits wire volume may be more primary variable than wire length or temporal delays, and moreover, the new spine economy principle may be important for brain evolutionary design in a broader context. PMID:26436731
Tsujino, J; Ihara, S; Harada, Y; Kasahara, K; Sakamaki, N
2004-04-01
Welding characteristic of thin coated copper wires were studied using 40, 60, 100 kHz ultrasonic complex vibration welding equipments with elliptical to circular vibration locus. The complex vibration systems consisted of a longitudinal-torsional vibration converter and a driving longitudinal vibration system. Polyurethane coated copper wires of 0.036 mm outer diameter and copper plates of 0.3 mm thickness and the other dimension wires were used as welding specimens. The copper wire part is completely welded on the copper substrate and the insulated coating material is driven from welded area to outsides of the wire specimens by high frequency complex vibration.
3D MHD Simulations of Radial Wire Array Z-pinches
NASA Astrophysics Data System (ADS)
Niasse, N.; Chittenden, J. P.; Bland, S. N.; Suzuki-Vidal, F. A.; Hall, G. N.; Lebedev, S. V.; Calamy, H.; Zucchini, F.; Lassalle, F.; Bedoch, J. P.
2009-01-01
Recent experiments carried out on the MAGPIE (1 MA, 250 ns), OEDIPE (730 kA, 1.5 μs) and SPHINX (4 MA, 700 ns)[1] facilities have shown the relatively high level of scalability of the Radial Wire Array Z-pinches. These configurations where the wires stretch radially outwards from a central cathode offer numerous advantages over standard cylindrical arrays. In particular, imploding in a very stable and compact way, they seem suitable for coupling to small scale hohlraums. Making use of the 3D resistive magneto-hydrodynamic code GORGON[2] developed at Imperial College, the dynamic of the radial wire arrays is investigated. Influence of the cathode hotspots and wires angle on the x-ray emissions is also discussed. Comparison with experiments is offered to validate the numerical studies.
New Insulation Constructions for Aerospace Wiring Applications. Volume 1. Testing and Evaluation
1991-06-01
28 S.3.2 CORONA INCEPTION AND EXTINCIION VOLTAGES 5 - 33 5.3.2.. AC CORONA INCEPTION AND EXTINCTION VOLTAGES 5...... - 33 5.3.2.2 DC CORONA ...SETUP ....... .. 5 - 27 5.10 DIELECTRIC CONSTANT TEST RESULTS .......... .. 5 - 32 5.11 AC CORONA INCEPTION AND EXTINCTION TEST, 22 AWG, 8.6 MIL WALL...AIRFRAME WIRE ... .......... 5 - 39 5.12 AC CORONA INCEPTION AND EXTINCTION TEST, 22 AWG, 5.8 MIL WALL, HOOK UP WIRE .... ........... 5 - 40 5.13 AC
Thompson, Kristin E; Korbmacher, Jonas P; Hecht, Elena; Hobi, Nina; Wittekindt, Oliver H; Dietl, Paul; Kranz, Christine; Frick, Manfred
2013-04-01
Two fundamental mechanisms within alveoli are essential for lung function: regulated fluid transport and secretion of surfactant. Surfactant is secreted via exocytosis of lamellar bodies (LBs) in alveolar type II (ATII) cells. We recently reported that LB exocytosis results in fusion-activated cation entry (FACE) via P2X₄ receptors on LBs. We propose that FACE, in addition to facilitating surfactant secretion, modulates alveolar fluid transport. Correlative fluorescence and atomic force microscopy revealed that FACE-dependent water influx correlated with individual fusion events in rat primary ATII cells. Moreover, ATII cell monolayers grown at air-liquid interface exhibited increases in short-circuit current (Isc) on stimulation with ATP or UTP. Both are potent agonists for LB exocytosis, but only ATP activates FACE. ATP, not UTP, elicited additional fusion-dependent increases in Isc. Overexpressing dominant-negative P2X₄ abrogated this effect by ∼50%, whereas potentiating P2X4 lead to ∼80% increase in Isc. Finally, we monitored changes in alveolar surface liquid (ASL) on ATII monolayers by confocal microscopy. Only stimulation with ATP, not UTP, led to a significant, fusion-dependent, 20% decrease in ASL, indicating apical-to-basolateral fluid transport across ATII monolayers. Our data support the first direct link between LB exocytosis, regulation of surfactant secretion, and transalveolar fluid resorption via FACE.
Ren, Xiaomei; El-Sagheer, Afaf H.; Brown, Tom
2016-01-01
A sterically undemanding azide analogue of dTTP (AHP dUTP) with an alkyl chain and ethynyl attachment to the nucleobase was designed and incorporated into DNA by primer extension, reverse transcription and polymerase chain reaction (PCR). An azide-modified 523 bp PCR amplicon with all 335 thymidines replaced by AHP dU was shown to be a perfect copy of the template from which it was amplified. Replacement of thymidine with AHP dU increases duplex stability, accounting in part for the high incorporation efficiency of the azide-modified triphosphate. Single-stranded azide-labelled DNA was conveniently prepared from PCR products by λ-exonuclease digestion and streptavidin magnetic bead isolation. Efficient fluorescent labelling of single and double-stranded DNA was carried out using dyes functionalized with bicyclo[6.1.0]non-4-yne (BCN) via the strain-promoted alkyne-azide cycloaddition (SPAAC) reaction. This revealed that the degree of labelling must be carefully controlled to achieve optimum fluorescence and avoid fluorescence quenching. Dual-coloured probes were obtained in a single tube fluorescent labelling reaction; and varying the ratios of the two dyes provides a simple method to prepare DNA probes with unique fluorescent signatures. AHP dUTP is a versatile clickable nucleotide with potentially wide applications in biology and nanotechnology including single molecule studies and synthesis of modified aptamer libraries via SELEX. PMID:26819406
Validation of heart rate extraction through an iPhone accelerometer.
Kwon, Sungjun; Lee, Jeongsu; Chung, Gih Sung; Park, Kwang Suk
2011-01-01
Ubiquitous medical technology may provide advanced utility for evaluating the status of the patient beyond the clinical environment. The iPhone provides the capacity to measure the heart rate, as the iPhone consists of a 3-axis accelerometer that is sufficiently sensitive to perceive tiny body movements caused by heart pumping. In this preliminary study, an iPhone was tested and evaluated as the reliable heart rate extractor to use for medical purpose by comparing with reference electrocardiogram. By comparing the extracted heart rate from acquired acceleration data with the extracted one from ECG reference signal, iPhone functioning as the reliable heart rate extractor has demonstrated sufficient accuracy and consistency.
A quasi-3D wire approach to model pulmonary airflow in human airways.
Kannan, Ravishekar; Chen, Z J; Singh, Narender; Przekwas, Andrzej; Delvadia, Renishkumar; Tian, Geng; Walenga, Ross
2017-07-01
The models used for modeling the airflow in the human airways are either 0-dimensional compartmental or full 3-dimensional (3D) computational fluid dynamics (CFD) models. In the former, airways are treated as compartments, and the computations are performed with several assumptions, thereby generating a low-fidelity solution. The CFD method displays extremely high fidelity since the solution is obtained by solving the conservation equations in a physiologically consistent geometry. However, CFD models (1) require millions of degrees of freedom to accurately describe the geometry and to reduce the discretization errors, (2) have convergence problems, and (3) require several days to simulate a few breathing cycles. In this paper, we present a novel, fast-running, and robust quasi-3D wire model for modeling the airflow in the human lung airway. The wire mesh is obtained by contracting the high-fidelity lung airway surface mesh to a system of connected wires, with well-defined radii. The conservation equations are then solved in each wire. These wire meshes have around O(1000) degrees of freedom and hence are 3000 to 25 000 times faster than their CFD counterparts. The 3D spatial nature is also preserved since these wires are contracted out of the actual lung STL surface. The pressure readings between the 2 approaches showed minor difference (maximum error = 15%). In general, this formulation is fast and robust, allows geometric changes, and delivers high-fidelity solutions. Hence, this approach has great potential for more complicated problems including modeling of constricted/diseased lung sections and for calibrating the lung flow resistances through parameter inversion. Copyright © 2016 John Wiley & Sons, Ltd.
3D shape measurement system developed on mobile platform
NASA Astrophysics Data System (ADS)
Wu, Zhoujie; Chang, Meng; Shi, Bowen; Zhang, Qican
2017-02-01
Three-dimensional (3-D) shape measurement technology based on structured light has become one hot research field inspired by the increasing requirements. Many methods have been implemented and applied in the industry applications, but most of their equipments are large and complex, cannot be portable. Meanwhile, the popularity of the smart mobile terminals, such as smart phones, provides a platform for the miniaturization and portability of this technology. The measurement system based on phase-shift algorithm and Gray-code pattern under the Android platform on a mobile phone is mainly studied and developed, and it has been encapsulated into a mobile phone application in order to reconstruct 3-D shape data in the employed smart phone easily and quickly. The experimental results of two measured object are given in this paper and demonstrate the application we developed in the mobile platform is effective.
Hanauer, David A.; Wentzell, Katherine; Laffel, Nikki
2009-01-01
Abstract Background: Cell phone text messaging, via the Short Messaging Service (SMS), offers the promise of a highly portable, well-accepted, and inexpensive modality for engaging youth and young adults in the management of their diabetes. This pilot and feasibility study compared two-way SMS cell phone messaging with e-mail reminders that were directed at encouraging blood glucose (BG) monitoring. Methods: Forty insulin-treated adolescents and young adults with diabetes were randomized to receive electronic reminders to check their BG levels via cell phone text messaging or e-mail reminders for a 3-month pilot study. Electronic messages were automatically generated, and participant replies with BG results were processed by the locally developed Computerized Automated Reminder Diabetes System (CARDS). Participants set their schedule for reminders on the secure CARDS website where they could also enter and review BG data. Results: Of the 40 participants, 22 were randomized to receive cell phone text message reminders and 18 to receive e-mail reminders; 18 in the cell phone group and 11 in the e-mail group used the system. Compared to the e-mail group, users in the cell phone group received more reminders (180.4 vs. 106.6 per user) and responded with BG results significantly more often (30.0 vs. 6.9 per user, P=0.04). During the first month cell phone users submitted twice as many BGs as e-mail users (27.2 vs. 13.8 per user); by month 3, usage waned. Conclusions: Cell phone text messaging to promote BG monitoring is a viable and acceptable option in adolescents and young adults with diabetes. However, maintaining interest levels for prolonged intervals remains a challenge. PMID:19848576
Geophysical Surveying of Shallow Magnetic Anomalies Using the iPhone Magnetometer
NASA Astrophysics Data System (ADS)
Opdyke, P.; Dudley, C.; Louie, J. N.
2012-12-01
This investigation examined whether the 3-axis Hall-effect magnetometer in the Apple iPhone 3GS can function as an effective shallow magnetic survey instrument. The xSensor Pro app from Crossbow Systems allows recoding of all three sensor components along with the GPS location, at a frequency of 1.0, 4.0, 16.0, and 32.0 Hz. If the iPhone proves successful in collecting useful magnetic data, then geophysicists and especially educators would have a new tool for high-density geophysical mapping. No-contract iPhones that can connect with WiFi can be obtained for about $400, allowing deployment of large numbers of instruments. iPhones with the xSensor Pro app surveyed in parallel with an Overhauser GEM system magnetometer (1 nT sensitivity) to test this idea. Anderson Bay, located on the Pyramid Lake Paiute Reservation, provided a rural survey location free from cultural interference. xSensor Pro, logged each component's intensity and the GPS location at a frequency of four measurements per second. Two Overhauser units functioned as a base unit and a roving unit. The roving unit collected total field at set points located with a handheld GPS. Comparing the total field computed from the iPhone components against that collected by the Overhauser establishes the level of anomalies that the iPhone can detect. iPhone total-field measurements commonly vary by 200 nT from point to point, so a spatial-temporal average over 25 seconds produces a smoothed signal for comparison. Preliminary analysis of the iPhone results show that the data do not accurately correlate to the total field collected by the Overhauser for any anomaly of less than 200 nT.
The Endockscope Using Next Generation Smartphones: "A Global Opportunity".
Tse, Christina; Patel, Roshan M; Yoon, Renai; Okhunov, Zhamshid; Landman, Jaime; Clayman, Ralph V
2018-06-02
The Endockscope combines a smartphone, a battery powered flashlight and a fiberoptic cystoscope allowing for mobile videocystoscopy. We compared conventional videocystoscopy to the Endockscope paired with next generation smartphones in an ex-vivo porcine bladder model to evaluate its image quality. The Endockscope consists of a three-dimensional (3D) printed attachment that connects a smartphone to a flexible fiberoptic cystoscope plus a 1000 lumen light-emitting diode (LED) cordless light source. Video recordings of porcine cystoscopy with a fiberoptic flexible cystoscope (Storz) were captured for each mobile device (iPhone 6, iPhone 6S, iPhone 7, Samsung S8, and Google Pixel) and for the high-definition H3-Z versatile camera (HD) set-up with both the LED light source and the xenon light (XL) source. Eleven faculty urologists, blinded to the modality used, evaluated each video for image quality/resolution, brightness, color quality, sharpness, overall quality, and acceptability for diagnostic use. When comparing the Endockscope coupled to an Galaxy S8, iPhone 7, and iPhone 6S with the LED portable light source to the HD camera with XL, there were no statistically significant differences in any metric. 82% and 55% of evaluators considered the iPhone 7 + LED light source and iPhone 6S + LED light, respectively, appropriate for diagnostic purposes as compared to 100% who considered the HD camera with XL appropriate. The iPhone 6 and Google Pixel coupled with the LED source were both inferior to the HD camera with XL in all metrics. The Endockscope system with a LED light source when coupled with either an iPhone 7 or Samsung S8 (total cost: $750) is comparable to conventional videocystoscopy with a standard camera and XL light source (total cost: $45,000).
Hanauer, David A; Wentzell, Katherine; Laffel, Nikki; Laffel, Lori M
2009-02-01
Cell phone text messaging, via the Short Messaging Service (SMS), offers the promise of a highly portable, well-accepted, and inexpensive modality for engaging youth and young adults in the management of their diabetes. This pilot and feasibility study compared two-way SMS cell phone messaging with e-mail reminders that were directed at encouraging blood glucose (BG) monitoring. Forty insulin-treated adolescents and young adults with diabetes were randomized to receive electronic reminders to check their BG levels via cell phone text messaging or e-mail reminders for a 3-month pilot study. Electronic messages were automatically generated, and participant replies with BG results were processed by the locally developed Computerized Automated Reminder Diabetes System (CARDS). Participants set their schedule for reminders on the secure CARDS website where they could also enter and review BG data. Of the 40 participants, 22 were randomized to receive cell phone text message reminders and 18 to receive e-mail reminders; 18 in the cell phone group and 11 in the e-mail group used the system. Compared to the e-mail group, users in the cell phone group received more reminders (180.4 vs. 106.6 per user) and responded with BG results significantly more often (30.0 vs. 6.9 per user, P = 0.04). During the first month cell phone users submitted twice as many BGs as e-mail users (27.2 vs. 13.8 per user); by month 3, usage waned. Cell phone text messaging to promote BG monitoring is a viable and acceptable option in adolescents and young adults with diabetes. However, maintaining interest levels for prolonged intervals remains a challenge.
Sleep Quality in Medical Students; the Impact of Over-Use of Mobile Cell-Phone and Social Networks.
Mohammadbeigi, Abolfazl; Absari, Rozita; Valizadeh, Farzaneh; Saadati, Mohammadreza; Sharifimoghadam, Soroush; Ahmadi, Ali; Mokhtari, Mohsen; Ansari, Hossein
2016-01-01
Poor sleep quality is closely associated with lifestyle habits including use of mobile cell-phones.This study aimed to identify the relationship between sleep quality due to abuse in mobile cell-phones and engagement in social networks. This cross-sectional study was conducted on 380 undergraduate students selected by proportional stratified sampling in Qom, Iran in 2015. Data were collected by two standard questionnaire including Cell-Phone Over-Use Scale (COS) and Pittsburgh sleep quality questionnaire beside the status of usage in cell-phone social networks. T-test, chi-square, Pearson correlation coefficient and multivariate logistic regression were used in data analysis. The mean age of participants was 21.8 ±3.2 yr, 69.1% were female, and 11.7% were married. The mean of COS and sleep quality scores were 48.18 ±17.5 and 5.38 ±2.31, respectively. The prevalence of over-use of cell phone was 10.7% (CI 0.95; 8.8%, 12.6%) and the prevalence of poor sleep quality was 61.7% (CI 0.95; 57.1%, 66.3%). The mean of all aspects and total score of sleep quality showed a direct significant association by cell-phone addiction score except sleep duration score that was inversely. Based on multivariate analysis affected to cell-phone addiction, being male gender and studying in general physician level are the most important predictors of poor sleep quality. Over use of internet and social networks via smart phones is related to poor sleep quality and quantity. Predefined sport programs, educational, cultural, and interesting entertainment are the essential needs for all medical students. These interventions are more important especially for male students who have longer educational.
Welding wire selection critical to jet engine repair work
NASA Astrophysics Data System (ADS)
1992-11-01
A review is provided of issues related to the selection of welding wire for aircraft gas-turbine engines emphasizing the importance of cleanliness in the welding wire product. A three-step metallurgical control process is described for the production of welding wire that is clean and suitable for turbine repair. The process is based on: (1) vacuum induction melting; (2) contamination-free processing of the wire; and (3) environmentally controlled packaging. Weld work on aerospace casting is shown to be useful and suitable for many alloy and superalloy materials with various filler materials.
NASA Astrophysics Data System (ADS)
Panmand, Rajendra P.; Kumar, Ganapathy; Mahajan, Satish M.; Kulkarni, Milind V.; Amalnerkar, D. P.; Kale, Bharat B.; Gosavi, Suresh. W.
2011-02-01
We report optical studies with magneto-optic properties of Bi2S3 quantum dot/wires-glass nanocomposite. The size of the Q-dot was observed to be in the range 3-15 nm along with 11 nm Q-wires. Optical study clearly demonstrated the size quantization effect with drastic band gap variation with size. Faraday rotation tests on the glass nanocomposites show variation in Verdet constant with Q-dot size. Bi2S3 Q-dot/wires glass nanocomposite demonstrated 190 times enhanced Verdet constant compared to the host glass. Prima facie observations exemplify the significant enhancement in Verdet constant of Q-dot glass nanocomposites and will have potential application in magneto-optical devices.
Method of manufacturing superconductor wire
Motowidlo, Leszek
2014-09-16
A method for forming Nb.sub.3Sn superconducting wire is provided. The method employs a powder-in-tube process using a high-tin intermetallic compound, such as MnSn.sub.2, for producing the Nb.sub.3Sn. The use of a high-tin intermetallic compound enables the process to perform hot extrusion without melting the high-tin intermetallic compound. Alternatively, the method may entail drawing the wire without hot extrusion.
Protocols using Anonymous Connections: Mobile Applications
1997-01-01
call from a cell phone ; the phone never receives a call in the ordinary sense of `receive’. We will return to discuss paging brie y below. The principals...speci ed in our protocol are the caller’s cell phone P , the central switch S, and the callee intended to receive the call R. We now present our...protocol for initiating a call from a cell phone . 1. P )P S : Payment info., N 2. S )P P : Ack or Nack 3. P ,P S $ R : Conversation To make a call from a
The upper critical field of filamentary Nb3Sn conductors
NASA Astrophysics Data System (ADS)
Godeke, A.; Jewell, M. C.; Fischer, C. M.; Squitieri, A. A.; Lee, P. J.; Larbalestier, D. C.
2005-05-01
We have examined the upper critical field of a large and representative set of present multifilamentary Nb3Sn wires and one bulk sample over a temperature range from 1.4 K up to the zero-field critical temperature. Since all present wires use a solid-state diffusion reaction to form the A15 layers, inhomogeneities with respect to Sn content are inevitable, in contrast to some previously studied homogeneous samples. Our study emphasizes the effects that these inevitable inhomogeneities have on the field-temperature phase boundary. The property inhomogeneities are extracted from field-dependent resistive transitions which we find broaden with increasing inhomogeneity. The upper 90%-99% of the transitions clearly separates alloyed and binary wires but a pure, Cu-free binary bulk sample also exhibits a zero-temperature critical field that is comparable to the ternary wires. The highest μ0Hc2 detected in the ternary wires are remarkably constant: The highest zero-temperature upper critical fields and zero-field critical temperatures fall within 29.5±0.3 and 17.8±0.3K, respectively, independent of the wire layout. The complete field-temperature phase boundary can be described very well with the relatively simple Maki-DeGennes model using a two-parameter fit, independent of composition, strain state, sample layout, or applied critical state criterion.
NASA Astrophysics Data System (ADS)
D'Hauthuille, Luc; Zhai, Yuhu; Princeton Plasma Physics Lab Collaboration; University of Geneva Collaboration
2015-11-01
High field superconductors play an important role in many large-scale physics experiments, particularly particle colliders and fusion devices such as the LHC and ITER. The two most common superconductors used are NbTi and Nb3Sn. Nb3Sn wires are favored because of their significantly higher Jc, allowing them to produce much higher magnetic fields. The main disadvantage is that the superconducting performance of Nb3Sn is highly strain-sensitive and it is very brittle. The strain-sensitivity is strongly influenced by two factors: plasticity and cracked filaments. Cracks are induced by large stress concentrators due to the presence of voids. We will attempt to understand the correlation between Nb3Sn's irreversible strain limit and the void-induced stress concentrations around the voids. We will develop accurate 2D and 3D finite element models containing detailed filaments and possible distributions of voids in a bronze-route Nb3Sn wire. We will apply a compressive transverse load for the various cases to simulate the stress response of a Nb3Sn wire from the Lorentz force. Doing this will further improve our understanding of the effect voids have on the wire's mechanical properties, and thus, the connection between the shape & distribution of voids and performance degradation.
[Mobile phones radiate--risk to the health?].
Jokela, Kari; Auvinen, Anssi; Hämäläinen, Heikki
2011-01-01
The mobile phones radiate electromagnetic energy which is partly absorbed into the tissues in the vicinity of the phone. The minor heating, in maximum up to 0.3 degrees C, may cause some alterations in the expression of genes and proteins similar to physiological response to other stimuli. Biophysical studies at the cellular and molecular level have not revealed any well established interaction mechanism, through which mobile phone radiation could induce toxic effects below the thermal effect level. Research results on various biological effects in vitro and in vivo are continuously published but there is no consistent evidence on well established harmful effects. The mobile phone radiation is not carcinogenic for experimental animals or genotoxic for cells. According to epidemiological studies and psychophysiological brain function studies the use of mobile phones does not seem to increase the risk of tumors in the head and brain or disturb the function of central nervous system. However, there is a need for more research on the long-term effects of mobile phone radiation particularly on children.
[The health problems which can brougth by 3G cell phones to our country].
Enöz, Murat
2009-01-01
At present, we are being exposed to electromagnetic pollution which is steadily increasing parallel to the technological advancements and which is invisible and unnoticeable in the short run. Electromagnetic waves which were previously used for therapeutic reasons have recently been uncontrollably used in daily life. By widespread use of 3rd generation (3G) cellular phones, the electromagnetic pollution has multiplied and brought us a huge amount of health dangers in our country. In this article, electromagnetic pollution, which is a comprehensive topic, and problems related with this kind of pollution which is rapidly increasing due to recent wide use of 3G cell phones are summarized in the light of the literature.
Evaluation of Android Smartphones for Telepathology
Ekong, Donald; Liu, Fang; Brown, G. Thomas; Ghosh, Arunima; Fontelo, Paul
2017-01-01
Background: In the year 2014, Android smartphones accounted for one-third of mobile connections globally but are predicted to increase to two-thirds by 2020. In developing countries, where teleconsultations can benefit health-care providers most, the ratio is even higher. This study compared the use of two Android phones, an 8 megapixel (MP) and a 16 MP phone, for capturing microscopic images. Method: The Android phones were used to capture images and videos of a gastrointestinal biopsy teaching set of referred cases from the Armed Forces Institute of Pathology (AFIP). The acquired images and videos were reviewed online by two pathologists for image quality, adequacy for diagnosis, usefulness of video overviews, and confidence in diagnosis, on a 5-point Likert scale. Results: The results show higher means in a 5-point Likert scale for the 8 MP versus the 16 MP phone that were statistically significant in adequacy of images (4.0 vs. 3.75) for rendering diagnosis and for agreement with the reference diagnosis (2.33 vs. 2.07). Although the quality of images was found higher in the 16 MP phone (3.8 vs. 3.65), these were not statistically significant. Adding video images of the entire specimen was found to be useful for evaluating the slides (combined mean, 4.0). Conclusion: For telepathology and other image dependent practices in developing countries, Android phones could be a useful tool for capturing images. PMID:28480119
Bhargav, Hemant; N K, Manjunath; Varambally, Shivarama; Mooventhan, A; Bista, Suman; Singh, Deepeshwar; Chhabra, Harleen; Venkatasubramanian, Ganesan; T M, Srinivasan; H R, Nagendra
2016-06-01
Mobile phone induced electromagnetic field (MPEMF) as well as chanting of Vedic mantra 'OM' has been shown to affect cognition and brain haemodynamics, but findings are still inconclusive. Twenty right-handed healthy teenagers (eight males and 12 females) in the age range of 18.25 ± 0.44 years were randomly divided into four groups: (1) MPONOM (mobile phone 'ON' followed by 'OM' chanting); (2) MPOFOM (mobile phone 'OFF' followed by 'OM' chanting); (3) MPONSS (mobile phone 'ON' followed by 'SS' chanting); and (4) MPOFSS (mobile phone 'OFF' followed by 'SS' chanting). Brain haemodynamics during Stroop task were recorded using a 64-channel fNIRS device at three points of time: (1) baseline, (2) after 30 min of MPON/OF exposure, and (3) after 5 min of OM/SS chanting. RM-ANOVA was applied to perform within- and between-group comparisons, respectively. Between-group analysis revealed that total scores on incongruent Stroop task were significantly better after OM as compared to SS chanting (MPOFOM vs MPOFSS), pre-frontal activation was significantly lesser after OM as compared to SS chanting in channel 13. There was no significant difference between MPON and MPOF conditions for Stroop performance, as well as brain haemodynamics. These findings need confirmation through a larger trial in future.
Evaluation of Android Smartphones for Telepathology.
Ekong, Donald; Liu, Fang; Brown, G Thomas; Ghosh, Arunima; Fontelo, Paul
2017-01-01
In the year 2014, Android smartphones accounted for one-third of mobile connections globally but are predicted to increase to two-thirds by 2020. In developing countries, where teleconsultations can benefit health-care providers most, the ratio is even higher. This study compared the use of two Android phones, an 8 megapixel (MP) and a 16 MP phone, for capturing microscopic images. The Android phones were used to capture images and videos of a gastrointestinal biopsy teaching set of referred cases from the Armed Forces Institute of Pathology (AFIP). The acquired images and videos were reviewed online by two pathologists for image quality, adequacy for diagnosis, usefulness of video overviews, and confidence in diagnosis, on a 5-point Likert scale. The results show higher means in a 5-point Likert scale for the 8 MP versus the 16 MP phone that were statistically significant in adequacy of images (4.0 vs. 3.75) for rendering diagnosis and for agreement with the reference diagnosis (2.33 vs. 2.07). Although the quality of images was found higher in the 16 MP phone (3.8 vs. 3.65), these were not statistically significant. Adding video images of the entire specimen was found to be useful for evaluating the slides (combined mean, 4.0). For telepathology and other image dependent practices in developing countries, Android phones could be a useful tool for capturing images.
Older adults and mobile phones for health: a review.
Joe, Jonathan; Demiris, George
2013-10-01
To report on the results of a review concerning the use of mobile phones for health with older adults. PubMed and CINAHL were searched for articles using "older adults" and "mobile phones" along with related terms and synonyms between 1965 and June 2012. Identified articles were filtered by the following inclusion criteria: original research project utilizing a mobile phone as an intervention, involve/target adults 60 years of age or older, and have an aim emphasizing the mobile phone's use in health. Twenty-one different articles were found and categorized into ten different clinical domains, including diabetes, activities of daily life, and dementia care, among others. The largest group of articles focused on diabetes care (4 articles), followed by COPD (3 articles), Alzheimer's/dementia Care (3 articles) and osteoarthritis (3 articles). Areas of interest studied included feasibility, acceptability, and effectiveness. While there were many different clinical domains, the majority of studies were pilot studies that needed more work to establish a stronger base of evidence. Current work in using mobile phones for older adult use are spread across a variety of clinical domains. While this work is promising, current studies are generally smaller feasibility studies, and thus future work is needed to establish more generalizable, stronger base of evidence for effectiveness of these interventions. Copyright © 2013 Elsevier Inc. All rights reserved.
Shelton, Jill T.; Elliott, Emily M.; Lynn, Sharon D.; Exner, Amanda L.
2010-01-01
The detrimental effects of a ringing phone on cognitive performance were investigated in four experiments. In Experiments 1 and 2, the effects of different types of sounds (a standard cell phone ring, irrelevant tones and an instrumental song commonly encountered by participants) on performance were examined. In Experiment 1, slower responses were observed in all auditory groups relative to a silence condition, but participants in the ring and song conditions recovered more slowly. In Experiment 2, participants who were warned about the potential for distraction recovered more quickly, suggesting a benefit of this prior knowledge. This investigation continued in a college classroom setting (Experiments 3a and 3b); students were exposed to a ringing cell phone during the lecture. Performance on a surprise quiz revealed low accuracy rates on material presented while the phone was ringing. These findings offer insight into top-down cognitive processes that moderate involuntary orienting responses associated with a common stimulus encountered in the environment. PMID:21234286
36 CFR § 1237.3 - What standards are incorporated by reference in this part?
Code of Federal Regulations, 2013 CFR
2013-07-01
...), National Archives and Records Administration, 8601 Adelphi Road, College Park, MD 20740-6001, phone number... Standards Institute, 25 West 43rd St., 4th Floor, New York, NY 10036, phone number (212) 642-4900, or online.... Box 9109, Quincy, MA 02269-9101, phone number (617) 770-3000 or online at http://catalog.nfpa.org. (1...
Guxens, Mònica; Vermeulen, Roel; van Eijsden, Manon; Beekhuizen, Johan; Vrijkotte, Tanja G M; van Strien, Rob T; Kromhout, Hans; Huss, Anke
2016-10-01
Little is known about the exposure of young children to radiofrequency electromagnetic fields (RF-EMF) and potentially associated health effects. We assessed the relationship between residential RF-EMF exposure from mobile phone base stations, residential presence of indoor sources, personal cell phone and cordless phone use, and children's cognitive function at 5-6 years of age. Cross-sectional study on children aged 5-6 years from the Amsterdam Born Children and their Development (ABCD) study, the Netherlands (n=2354). Residential RF-EMF exposure from mobile phone base stations was estimated with a 3D geospatial radio wave propagation model. Residential presence of indoor sources (cordless phone base stations and Wi-Fi) and children's cell phone and cordless phone use was reported by the mother. Speed of information processing, inhibitory control, cognitive flexibility, and visuomotor coordination was assessed using the Amsterdam Neuropsychological Tasks. Residential presence of RF-EMF indoor sources was associated with an improved speed of information processing. Higher residential RF-EMF exposure from mobile phone base stations and presence of indoor sources was associated with an improved inhibitory control and cognitive flexibility whereas we observed a reduced inhibitory control and cognitive flexibility with higher personal cordless phone use. Higher residential RF-EMF exposure from mobile phone base stations was associated with a reduced visuomotor coordination whereas we observed an improved visuomotor coordination with residential presence of RF-EMF indoor sources and higher personal cell phone use. We found inconsistent associations between different sources of RF-EMF exposure and cognitive function in children aged 5-6 years. Copyright © 2016 Elsevier Inc. All rights reserved.
Aluminum-Scandium: A Material for Semiconductor Packaging
NASA Astrophysics Data System (ADS)
Geissler, Ute; Thomas, Sven; Schneider-Ramelow, Martin; Mukhopadhyay, Biswajit; Lang, Klaus-Dieter
2016-10-01
A well-known aluminum-scandium (Al-Sc) alloy, already used in lightweight sports equipment, is about to be established for use in electronic packaging. One application for Al-Sc alloy is manufacture of bonding wires. The special feature of the alloy is its ability to harden by precipitation. The new bonding wires with electrical conductivity similar to pure Al wires can be processed on common wire bonders for aluminum wedge/wedge (w/w) bonding. The wires exhibit very fine-grained microstructure. Small Al3Sc particles are the main reason for its high strength and prevent recrystallization and grain growth at higher temperatures (>150°C). After the wire-bonding process, the interface is well closed. Reliability investigations by active power cycling demonstrated considerably improved lifetime compared with pure Al heavy wires. Furthermore, the Al-Sc alloy was sputter-deposited onto silicon wafer to test it as chip metallization in copper (Cu) ball/wedge bonding technology. After deposition, the layers exhibited fine-grained columnar structure and small coherent Al3Sc particles with dimensions of a few nanometers. These particles inhibit softening processes such as Al splashing in fine wire bonding processes and increase the thickness of remnant Al under the copper balls to 85% of the initial thickness.
Munshi, Anusheel; Dutta, Debanarayan; Tike, Pramod; Agarwal, Jai Prakash
2016-01-01
Obtain baseline data of cell-phone usage in the medical (MO), surgical (SO) and radiation (RO) oncology community practicing in India. Indigenously prepared cell-phone usage related questionnaire was used in the present study after approval by the Institutional Ethics/Scientific Committees. The questionnaire had 41 items and was made to assess the cell-phone usage parameters, utility in clinical practice, awareness, and to compare parameters between oncology specialties. Between November 2009 and January 2010, the questionnaire was sent as an E-mail attachment to 200 oncologists in India. In all, 123 responses were received (61% responders); 84 (68.3%) were RO. The median age of responders was 35 years. Overall, 80% felt handicapped without cell-phone. The Mean cell-phone score, an index to assess overall usefulness over a score of 1-10, was 6.46 (median 7, standard deviation 1.709). There was no significant difference between RO, MO and SO in duration of usage (P = 0.235), number of cell-phones (P = 0.496), call duration per day (P = 0.490) and dependence on cell-phone (P = 0.574). Age of starting cell-phone usage was earlier in RO (P = 0.086). Professional usage was significantly more by MO and SO compared to RO (P < 0.001); however, the former were less aware of any potential cell-phone hazards compared to RO (P < 0.007). The results of the first such questionnaire based study have been presented. Most oncologists consider cell-phones a useful tool in patient care. More RO are aware of potential cell-phone hazards compared to non-RO's.
The impact of cell phone use on the intensity and liking of a bout of treadmill exercise.
Rebold, Michael J; Lepp, Andrew; Sanders, Gabriel J; Barkley, Jacob E
2015-01-01
This study used a within-subjects design to assess the effect of three common cellular telephone (cell phone) functions (texting, talking, listening to music) on planned exercise. Forty-four young adults (n = 33 females, 21.8 ± 1.3 years) each participated in four, separate, 30-minute exercise conditions on a treadmill in a random order. During each condition, the treadmill speed display was covered and grade was fixed at zero. However, participants were able to alter treadmill speed as desired. Throughout the texting and talking conditions, research personnel used a pre-determined script to simulate cell phone conversations. During the music condition, participants used their cell phone to listen to music of their choice. Finally, participants completed a control condition with no cell phone access. For each condition, average treadmill speed, heart rate and liking (via visual analog scale) were assessed. Treadmill speed (3.4 ± 1.3 miles∙hour(-1)), heart rate (122.3 ± 24.3 beats∙min(-1)) and liking (7.5 ± 1.5 cm) in the music condition were significantly (p ≤ 0.014) greater than all other conditions. Treadmill speed in the control condition (3.1 ± 1.2 miles∙hour(-1)) was significantly (p = 0.04) greater than both texting and talking (2.8 ± 1.1 miles∙hour(-1) each). Heart rate during the control condition (115.4 ± 22.8 beats∙min(-1)) was significantly (p = 0.04) greater than texting (109.9 ± 16.4 beats∙min(-1)) but not talking (112.6 ± 16.1 beats∙min(-1)). Finally, liking during the talking condition (5.4 ± 2.2 cm) was greater (p = 0.05) than the control (4.3 ± 2.2 cm) but not the texting (5.1 ± 2.2 cm) conditions. In conclusion, using a cell phone for listening to music can increase the intensity (speed and heart rate) and liking of a bout of treadmill exercise. However, other common cell phone uses (texting and talking) can interfere with treadmill exercise and reduce intensity.
The Impact of Cell Phone Use on the Intensity and Liking of a Bout of Treadmill Exercise
Rebold, Michael J.; Lepp, Andrew; Sanders, Gabriel J.; Barkley, Jacob E.
2015-01-01
This study used a within-subjects design to assess the effect of three common cellular telephone (cell phone) functions (texting, talking, listening to music) on planned exercise. Forty-four young adults (n = 33 females, 21.8 ± 1.3 years) each participated in four, separate, 30-minute exercise conditions on a treadmill in a random order. During each condition, the treadmill speed display was covered and grade was fixed at zero. However, participants were able to alter treadmill speed as desired. Throughout the texting and talking conditions, research personnel used a pre-determined script to simulate cell phone conversations. During the music condition, participants used their cell phone to listen to music of their choice. Finally, participants completed a control condition with no cell phone access. For each condition, average treadmill speed, heart rate and liking (via visual analog scale) were assessed. Treadmill speed (3.4 ± 1.3 miles∙hour-1), heart rate (122.3 ± 24.3 beats∙min-1) and liking (7.5 ± 1.5 cm) in the music condition were significantly (p ≤ 0.014) greater than all other conditions. Treadmill speed in the control condition (3.1 ± 1.2 miles∙hour-1) was significantly (p = 0.04) greater than both texting and talking (2.8 ± 1.1 miles∙hour-1 each). Heart rate during the control condition (115.4 ± 22.8 beats∙min-1) was significantly (p = 0.04) greater than texting (109.9 ± 16.4 beats∙min-1) but not talking (112.6 ± 16.1 beats∙min-1). Finally, liking during the talking condition (5.4 ± 2.2 cm) was greater (p = 0.05) than the control (4.3 ± 2.2 cm) but not the texting (5.1 ± 2.2 cm) conditions. In conclusion, using a cell phone for listening to music can increase the intensity (speed and heart rate) and liking of a bout of treadmill exercise. However, other common cell phone uses (texting and talking) can interfere with treadmill exercise and reduce intensity. PMID:25970553
Experimental verification of a gain reduction model for the space charge effect in a wire chamber
NASA Astrophysics Data System (ADS)
Nagakura, Naoki; Fujii, Kazuki; Harayama, Isao; Kato, Yu; Sekiba, Daiichiro; Watahiki, Yumi; Yamashita, Satoru
2018-01-01
A wire chamber often suffers significant saturation of the multiplication factor when the electric field around its wires is strong. An analytical model of this effect has previously been proposed [Y. Arimoto et al., Nucl. Instrum. Meth. Phys. Res. A 799, 187 (2015)], in which the saturation was described by the multiplication factor, energy deposit density per wire length, and one constant parameter. In order to confirm the validity of this model, a multi-wire drift chamber was developed and irradiated by a MeV-range proton beam at the University of Tsukuba. The saturation effect was compared for energy deposits ranging from 70 keV/cm to 180 keV/cm and multiplication factors 3× 103 to 3× 104. The chamber was rotated with respect to the proton beam in order to vary the space charge density around the wires. The energy deposit distribution corrected for the effect was consistent with the result of a Monte Carlo simulation, thus validating the proposed model.
Kachoei, Mojgan; Nourian, Azin; Divband, Baharak; Kachoei, Zahra; Shirazi, Sajjad
2016-10-01
To fabricate a friction-reducing and antibacterial coating with zinc oxide (ZnO) nanoparticles on nickel-titanium (NiTi) wire. NiTi orthodontic wires were coated with ZnO nanoparticles using the chemical deposition method. Characteristics of the coating as well as the physical, mechanical and antibacterial properties of the wires were investigated. A stable and well-adhered ZnO coating on the NiTi wires was obtained. The hardness and elastic modulus of the ZnO nanocoating were 2.3 ± 0.2 and 61.0 ± 3.6 GPa, respectively. The coated wires presented up to 21% reduction in the frictional forces and antibacterial activity against Streptococcus mutans. ZnO nanocoating significantly improved the surface quality of NiTi wires. The modulus of elasticity, unloading forces and austenite finish temperature were not significantly different after coating. This unique coating could be implemented into practice for safer and faster treatment to the benefit of both patient and clinician.
King, J A; Ball, J K
1993-09-01
An extremely sensitive and convenient microtiter plate solution hybridisation assay for the detection of HIV-1 PCR products was developed. The PCR product is labelled by direct incorporation of digoxigenin-dUTP and after denaturation is captured by a microtitre plate coated with a streptavidin-linked biotinylated probe. The PCR/probe hybrids are reacted with an alkaline phosphate conjugated anti-digoxigenin antibody and detected using an alkaline phosphatase enzyme amplification system. The use of uracil-N-glycosylase and dUTP instead of dTTP in the PCR is used to effectively control carry-over from previous PCR products. The assay can detect single HIV-1 DNA molecules in a background DNA of 0.75 microgram.
Kararia, Vandana; Jain, Pradeep; Chaudhary, Seema; Kararia, Nitin
2015-01-01
The biocompatibility of orthodontic dental alloys has been investigated over the past 20 years, but the results have been inconclusive. The study compares standard 3 M Unitek nickel-titanium (NiTi) and stainless steel archwires with locally available JJ orthodontics wires. Scanning electron microscope (SEM) study of surface changes and complexometric titration to study compositional change was performed. Ten archwires each of group 1-3 M 0.016" NiTi, group 2-JJ 0.016" NiTi, group 3-3 M 0.019" *0.025" SS and group 4-JJ SS contributed a 10 mm piece of wire for analysis prior to insertion in the patient and 6 weeks post insertion. SEM images were recorded at ×2000, ×4000 and ×6000 magnification. The same samples were subjected to complexiometric titration using ethylenediaminetetraacetic acid to gauge the actual change in the composition. The SEM images of all the archwires showed marked changes with deep scratches and grooves and dark pitting corrosion areas post intraoral use. 3M wires showed an uniform criss-cross pattern in as received wires indicating a coating which was absent after intraoral use. There was a significant release of Nickel and Chromium from both group 3 and 4. Group 2 wires released ions significantly more than group 1 (P = 0.0). Extensive and stringent trials are required before certifying any product to be used in Orthodontics.
Molecular Recognition at Purine and Pyrimidine Nucleotide (P2) Receptors
Jacobson, Kenneth A.; Constanzi, Stefano; Ohno, Michihiro; Joshi, Bhalchandra V.; Besada, Pedro; Xu, Bin; Tchilibon, Susanna
2015-01-01
In comparison to other classes of cell surface receptors, the medicinal chemistry at P2X (ligand-gated ion channels) and P2Y (G protein-coupled) nucleotide receptors has been relatively slow to develop. Recent effort to design selective agonists and antagonists based on a combination of library screening, empirical modification of known ligands, and rational design have led to the introduction of potent antagonists of the P2X1 (derivatives of pyridoxal phosphates and suramin), P2X3 (A-317491), P2X7 (derivatives of the isoquinoline KN-62), P2Y1 (nucleotide analogues MRS 2179 and MRS 2279), P2Y2 (thiouracil derivatives such as AR-C126313), and P2Y12 (nucleotide/nucleoside analogues AR-C69931X and AZD6140) receptors. A variety of native agonist ligands (ATP, ADP, UTP, UDP, and UDP-glucose) are currently the subject of structural modification efforts to improve selectivity. MRS2365 is a selective agonist for P2Y1 receptors. The dinucleotide INS 37217 potently activates the P2Y2 receptor. UTP-γ-S and UDP-β-S are selective agonists for P2Y2/P2Y4 and P2Y6 receptors, respectively. The current knowledge of the structures of P2X and P2Y receptors, is derived mainly from mutagenesis studies. Site-directed mutagenesis has shown that ligand recognition in the human P2Y1 receptor involves individual residues of both the TMs (3, 5, 6, and 7), as well as EL 2 and 3. The binding of the negatively-charged phosphate moiety is dependent on positively charged lysine and arginine residues near the exofacial side of TMs 3 and 7. PMID:15078212
Crystal structure of dUTP pyrophosphatase from feline immunodeficiency virus.
Prasad, G. S.; Stura, E. A.; McRee, D. E.; Laco, G. S.; Hasselkus-Light, C.; Elder, J. H.; Stout, C. D.
1996-01-01
We have determined the crystal structure of dUTP pyrophosphatase (dUTPase) from feline immunodeficiency virus (FIV) at 1.9 A resolution. The structure has been solved by the multiple isomorphous replacement (MIR) method using a P6(3) crystal form. The results show that the enzyme is a trimer of 14.3 kDa subunits with marked structural similarity to E. coli dUTPase. In both enzymes the C-terminal strand of an anti-parallel beta-barrel participates in the beta-sheet of an adjacent subunit to form an interdigitated, biologically functional trimer. In the P6(3) crystal form one trimer packs on the 6(3) screw-axis and another on the threefold axis so that there are two independent monomers per asymmetric unit. A Mg2+ ion is coordinated by three asparate residues on the threefold axis of each trimer. Alignment of 17 viral, prokaryotic, and eukaryotic dUTPase sequences reveals five conserved motifs. Four of these map onto the interface between pairs of subunits, defining a putative active site region; the fifth resides in the C-terminal 16 residues, which is disordered in the crystals. Conserved motifs from all three subunits are required to create a given active site. With respect to viral protein expression, it is particularly interesting that the gene for dUTPase (DU) resides in the middle of the Pol gene, the enzyme cassette of the retroviral genome. Other enzymes encoded in the Pol polyprotein, including protease (PR), reverse transcriptase (RT), and most likely integrase (IN), are dimeric enzymes, which implies that the stoichiometry of expression of active trimeric dUTPase is distinct from the other Pol-encoded enzymes. Additionally, due to structural constraints, it is unlikely that dUTPase can attain an active form prior to cleavage from the polyprotein. PMID:8976551
NASA Technical Reports Server (NTRS)
1972-01-01
A cost study comparing flat conductor cable (FCC) with small-gage wire (SGW) and conventional round conductor cable (RCC) is presented. This study was based on a vehicle wiring system consisting of 110,000 ft of conventional RCC equally divided between AWG sizes 20,22, and 24 using MIL-W-81044-type wire and MIL-C-26500 circular connectors. Basic cost data were developed on a similar-sized commercial jet airplane wiring system on a previous company R&D program in which advanced wiring techniques were carried through equivalent installations on an airplane mockup; and on data developed on typical average bundles during this program. Various cost elements included were engineering labor, operations (manufacturing) labor, material costs, and cost impact on payload. Engineering labor includes design, wiring system integration, wiring diagrams and cable assembly drawings, wire installations, and other related supporting functions such as the electronic data processing for the wiring. Operations labor includes mockup, tooling and production planning, fabrication, assembly, installation, and quality control cost impact on payload is the conversion of wiring system weight variations through use of different wiring concepts to program payload benefits in terms of dollars.
Hu, Chun-Lin; Wei, Hong-Yan; Liu, Zi-You; Li, Xing; Liao, Xiao-Xing; Li, Yu-Jie; Zhan, Hong; Jing, Xiao-Li; Xiong, Yan; Liu, Yan-Yan; Wu, Gui-Fu
2010-12-01
To establish a simple, economic, and reliable alternating current (AC)-induced cardiac arrest (ACCA) model in rabbits for cardiopulmonary cerebral resuscitation research. Ventricular fibrillation was induced in 27 New Zealand rabbits by external transthoracic AC, which were randomly divided into three groups according to the duration of untreated ACCA (ACCA-3 minutes, ACCA-5 minutes, and ACCA-8 minutes). After ACCA, all animals received cardiopulmonary resuscitation for 2 minutes and subsequent defibrillation until return of spontaneous circulation (ROSC). The troponin I levels were measured at 4 hours after ROSC. Animals died spontaneously or were killed at 72 hours after ROSC. The hippocampus were removed and fixed in 3% formalin. TdT-mediated dUTP-biotin nick end labeling and Nissl stainings were performed in 10-μm thickness coronal sections. Furthermore, two rabbits (without induction of ventricular fibrillation, cardiopulmonary resuscitation, and defibrillation) served as normal control group. Mean survival times after ROSC were 48.57 hours ± 24.70 hours, 18.0 hours ± 15.13 hours, and 3.88 hours ± 2.39 hours for groups ACCA-3 minutes, ACCA-5 minutes, and ACCA-8 minutes, respectively. Survival was significantly different between ACCA-3 minutes and other two groups (p = 0.002 and p = 0.01). Neuronal necrosis and apoptosis were found in the hippocampus CA1, CA2, and CA3 areas of group ACCA-3 minutes. In contrast, neuronal necrosis and TdT-mediated dUTP-biotin nick end labeling positive cells were fewer in control animals. The rabbits in group ACCA-3 minutes had significant neuronal damage with apoptosis in hippocampus CA1, CA2, and CA3 areas at 72 hours after ROSC and survived longer than those in other groups. The model we describe may be a simple, economic, and reliable model for experimental investigation on cardiopulmonary cerebral resuscitation.
Ferroelectric and photocatalytic behavior of bismuth ferrite nano wire
DOE Office of Scientific and Technical Information (OSTI.GOV)
William, R. V.; Marikani, A., E-mail: amari@mepcoeng.ac.in; Madhavan, D.
Multiferroic bismuth ferrite nanowires are prepared through polyol method with an average diameter of 35 nm with a narrow size distribution. The band gap was determined to be 2.10 eV, indicating their potential application as visible-light-response photo catalyst. The magnificent photocatalytic behaviors of BiFeO{sub 3} nanowires are understood from the methyl violet degradation under visible light irradiation. Moreover, the nano-wire takes only a lesser time for the diffusion of electron-hole pair from the surface of the sample. Further the BiFeO{sub 3} nano-wire was characterized using XRD, SEM, and U-V. The ferroelectric studies of BiFeO{sub 3} nano-wire show a frequency dependent propertymore » and maximum coercivity of 2.7 V/cm were achieved with a remanent polarization at 0.5 µC/cm{sup 2} at the frequency 4 kHz. The coercivity of BiFeO{sub 3} nano wire changes with variation of frequency from 1 kHz to 4 kHz.« less
Altering Adolescents' Pre-Bedtime Phone Use to Achieve Better Sleep Health.
Bartel, K; Scheeren, R; Gradisar, M
2018-01-09
Mobile phone use is often blamed for adolescent sleeping difficulties in the popular and scientific literature, with correlations observed between adolescents' mobile phone use and their bedtime. We aimed to obtain experimental evidence to support these causal claims. A within-subjects experiment (baseline, intervention) was conducted in adolescents' homes, to determine the effect of restricting adolescents' pre-bed mobile phone use on school night sleep habits. Following a baseline week, adolescents were given individualized phone stop times, 1 hour before bed for one school week. An online sleep diary was used to monitor bedtime, lights out time, sleep latency and total sleep. Sixty three adolescents (age range 14-18, M = 16.3, SD = 0.93yrs; 17%male) provided data. During one week of phone restriction, adolescents stopped using their phones earlier (80 min, p < .001), turned their lights off earlier (17 min, p = .01), and slept longer (21 min, p = .01). Participant recruitment was low (26%), indicating many adolescents lack motivation to negotiate changes to their evening phone use. Overall, there are potential benefits of restricted mobile phone use during the pre-sleep period, yet, future research is needed to identify non-technological interventions to increase adherence to phone restriction (e.g., motivational interviewing) or otherwise decrease pre-sleep arousal (e.g., cognitive strategies).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tachikawa, K.; Sasaki, H.; Yamaguchi, M.
Tightly consolidated Sn-Ta and Sn-B based alloys have been prepared by the reaction among constituent metal powders at 750-775 deg. C. Sn-Ta and Sn-B based alloys exhibit quite similar microstructures. A small amount of Ti addition seems to improve the bonding between Ta or B particles and Sn matrix. Nb{sub 3}Sn wires have been fabricated by the Jelly Roll (JR) and Multi-rod (MR) process using Sn based alloy sheet and rod, respectively. Thick Nb{sub 3}Sn layers with nearly stoichiometric A15 composition are synthesized through a new diffusion mechanism between Nb and Sn based alloy. B{sub c2}(4.2 K)'s of 26.9 Tmore » (mid) and 26.5 T (mid) have been obtained in the JR and MR processed wires, respectively, using Sn-Ta based alloy. These wires exhibit enough non-Cu J{sub c} to be used above 20 T and 4.2 K. T{sub c} of JR wires using Sn-B based sheet is 18.14 K (offset) which is slightly higher than that of wires using Sn-Ta based sheet.« less
Self-organization of mesoscopic silver wires by electrochemical deposition.
Zhong, Sheng; Koch, Thomas; Walheim, Stefan; Rösner, Harald; Nold, Eberhard; Kobler, Aaron; Scherer, Torsten; Wang, Di; Kübel, Christian; Wang, Mu; Hahn, Horst; Schimmel, Thomas
2014-01-01
Long, straight mesoscale silver wires have been fabricated from AgNO3 electrolyte via electrodeposition without the help of templates, additives, and surfactants. Although the wire growth speed is very fast due to growth under non-equilibrium conditions, the wire morphology is regular and uniform in diameter. Structural studies reveal that the wires are single-crystalline, with the [112] direction as the growth direction. A possible growth mechanism is suggested. Auger depth profile measurements show that the wires are stable against oxidation under ambient conditions. This unique system provides a convenient way for the study of self-organization in electrochemical environments as well as for the fabrication of highly-ordered, single-crystalline metal nanowires.
Use of iPhone technology in improving acetabular component position in total hip arthroplasty.
Tay, Xiau Wei; Zhang, Benny Xu; Gayagay, George
2017-09-01
Improper acetabular cup positioning is associated with high risk of complications after total hip arthroplasty. The aim of our study is to objectively compare 3 methods, namely (1) free hand, (2) alignment jig (Sputnik), and (3) iPhone application to identify an easy, reproducible, and accurate method in improving acetabular cup placement. We designed a simple setup and carried out a simple experiment (see Method section). Using statistical analysis, the difference in inclination angles using iPhone application compared with the freehand method was found to be statistically significant ( F [2,51] = 4.17, P = .02) in the "untrained group". There is no statistical significance detected for the other groups. This suggests a potential role for iPhone applications in junior surgeons in overcoming the steep learning curve.
Superconducting wire manufactured
NASA Astrophysics Data System (ADS)
Fu, Yuexian; Sun, Yue; Xu, Shiming; Peng, Ying
1985-10-01
The MF Nb/Cu Extrusion Tube Method was used to manufacture 3 kg of stable practical MF Nb2Sn composite superconducting wire containing pure Cu(RRR approx. 200)/Ta. The draw state composite wire diameter was 0.56 mm, it contained 11,448 x 2.6 micron Nb core, and the twist distance was 1.5 cm. The composite wire cross-section was pure Cu/Ta/11,448 Nb core/Cu/ 91Sn-Cu; containing 22.8 v. % pure Cu, 13.3 v. % Ta; within the Ta layer to prevent Sn diffusion. The wire was sheathed in nonalkaline glass fiber as an insulating layer. A section of wire weighing 160 g was cut off and coiled it into a small solenoid. After reaction diffusion processing at 675 C/30 and curing by vacuum dipping in paraffin, it was measured in a Nb-Ti backfield of 7.2 T intensity, a current of 129 A was passed through the Nb3Sn solenoid and produced a strength of 2.5 T, the overall magnetic field intensity of the composite magnet reached 9.7 T. At this time, the wire full current density J sub c.w. = 5.2 x 10 to the 4th power A/sq cm; the effective current density J sub c (Nb + Sn - Cu) = 8.2 x 10 to the 4th power A/sq cm.
Tomé, Angelo R; Castro, Enrique; Santos, Rosa M; Rosário, Luís M
2007-06-14
Adrenal chromaffin cells mediate acute responses to stress through the release of epinephrine. Chromaffin cell function is regulated by several receptors, present both in adrenergic (AD) and noradrenergic (NA) cells. Extracellular ATP exerts excitatory and inhibitory actions on chromaffin cells via ionotropic (P2X) and metabotropic (P2Y) receptors. We have taken advantage of the actions of the purinergic agonists ATP and UTP on cytosolic free Ca2+ concentration ([Ca2+]i) to determine whether P2X and P2Y receptors might be asymmetrically distributed among AD and NA chromaffin cells. The [Ca2+]i and the [Na+]i were recorded from immunolabeled bovine chromaffin cells by single-cell fluorescence imaging. Among the ATP-sensitive cells ~40% did not yield [Ca2+]i responses to ATP in the absence of extracellular Ca2+ (Ca2+o), indicating that they expressed P2X receptors and did not express Ca2+- mobilizing P2Y receptors; the remainder expressed Ca2+-mobilizing P2Y receptors. Relative to AD-cells approximately twice as many NA-cells expressed P2X receptors while not expressing Ca2+- mobilizing P2Y receptors, as indicated by the proportion of cells lacking [Ca2+]i responses and exhibiting [Na+]i responses to ATP in the absence and presence of Ca2+o, respectively. The density of P2X receptors in NA-cells appeared to be 30-50% larger, as suggested by comparing the average size of the [Na+]i and [Ca2+]i responses to ATP. Conversely, approximately twice as many AD-cells expressed Ca2+-mobilizing P2Y receptors, and they appeared to exhibit a higher (~20%) receptor density. UTP raised the [Ca2+]i in a fraction of the cells and did not raise the [Na+]i in any of the cells tested, confirming its specificity as a P2Y agonist. The cell density of UTP-sensitive P2Y receptors did not appear to vary among AD- and NA-cells. Although neither of the major purinoceptor types can be ascribed to a particular cell phenotype, P2X and Ca2+-mobilizing P2Y receptors are preferentially located to noradrenergic and adrenergic chromaffin cells, respectively. ATP might, in addition to an UTP-sensitive P2Y receptor, activate an UTP-insensitive P2Y receptor subtype. A model for a short-loop feedback interaction is presented whereby locally released ATP acts upon P2Y receptors in adrenergic cells, inhibiting Ca2+ influx and contributing to terminate evoked epinephrine secretion.
Tolbutamide attenuates diazoxide-induced aggravation of hypoxic cell injury.
Pissarek, M; Reichelt, C; Krauss, G J; Illes, P
1998-11-23
ATP-dependent potassium (KATP) channels of neurons are closed in the presence of physiological levels of intracellular ATP and open when ATP is depleted during hypoxia or metabolic damage. The present study investigates hypoxic alterations of purine and pyrimidine nucleotide levels supposed to intracellularly modulate KATP channels. In addition, the effects of the KATP channel activator diazoxide and its antagonist tolbutamide were investigated on ATP, GTP, CTP and UTP levels in slices of the parietal cortex. Hypoxia was evoked by saturation of the medium with 95% N2-5% CO2 instead of 95% O2-5% CO2 for 5 min. Nucleotide contents were measured by anion-exchange HPLC in neutralized perchloric acid extracts obtained from slices frozen immediately at the end of incubation. Hypoxia per se decreased purine and pyrimidine nucleoside triphosphate contents. Thus, ATP and GTP contents were reduced to 69.9 and 77.6% of the respective normoxic levels. UTP and CTP contents were even more decreased (to 60.9 and 41.6%),, probably because the salvage pathway of these pyrimidine nucleotides is less effective than that of the purine nucleotides ATP and GTP. While tolbutamide (30 microM) had no effect on the hypoxia-induced decrease of nucleotides, diazoxide at 300, but not 30 microM aggravated the decline of ATP, UTP and CTP to 51.8, 37.5 and 28.5% of the contents observed at normoxia; GTP levels also showed a tendency to decrease after diazoxide application. Tolbutamide (300 microM) antagonized the effects of diazoxide (300 but not 30 microM aggravated the decline of ATP, UTP and CTP to 51.8, 37.5 and 28.5% of the contents observed at normoxia; GTP levels also showed a tendency to decrease after diazoxide application. Tolbutamide (300 microM) antagonized the effects of diazoxide (300 MicroM). Nucleoside diphosphate (ADP, GDP and UDP) levels were uniformly increased by hypoxia. There was no hypoxia-induced increase of ADP contents in the presence of tolbutamide (300 microM). The ATP/ADP, GTP/GDP and UTP/UDP ratios uniformly declined at a low pO2. However, only the ATP/ADP ratio was decreased further by diazoxide (300 microM). The observed alterations in nucleotide contents may be of importance for long- and short-term processes related to acute cerebral hypoxia. Thus, hypoxia-induced alterations of purine and pyrimidine nucleotide levels may influence the open state of KATP-channels during the period of reversible hypoxic cerebral injury. Furthermore, alterations during the irreversible period of cerebral injury may also arise, as a consequence of decreased pyrimidine nucleotide contents affecting cell survival viaprotein and DNA synthesis.
47 CFR 69.304 - Subscriber line cable and wire facilities.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 3 2010-10-01 2010-10-01 false Subscriber line cable and wire facilities. 69.304 Section 69.304 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES (CONTINUED) ACCESS CHARGES Apportionment of Net Investment § 69.304 Subscriber line cable and wire...
47 CFR 69.305 - Carrier cable and wire facilities (C&WF).
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 3 2010-10-01 2010-10-01 false Carrier cable and wire facilities (C&WF). 69.305 Section 69.305 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES (CONTINUED) ACCESS CHARGES Apportionment of Net Investment § 69.305 Carrier cable and wire...
47 CFR 69.304 - Subscriber line cable and wire facilities.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 3 2011-10-01 2011-10-01 false Subscriber line cable and wire facilities. 69.304 Section 69.304 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES (CONTINUED) ACCESS CHARGES Apportionment of Net Investment § 69.304 Subscriber line cable and wire...
47 CFR 69.305 - Carrier cable and wire facilities (C&WF).
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 3 2011-10-01 2011-10-01 false Carrier cable and wire facilities (C&WF). 69.305 Section 69.305 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES (CONTINUED) ACCESS CHARGES Apportionment of Net Investment § 69.305 Carrier cable and wire...
2015-09-01
changing the weight file used without redeploying the application. 2.1 Mobile Device We used the same Sprint-brand Galaxy S3 smart phone. The... Galaxy S3 line of smart phones varied in its technical specifications depending on the carrier. For reference, the Sprint-brand Galaxy S3 has the
Online Medicine for Pregnant Women
Davidesko, Sharon; Segal, David
2014-01-01
Objective. To assess the use of cell phones and email as means of communication between pregnant women and their gynecologists and family physicians. Study Design. A cross-sectional study of pregnant women at routine followup. One hundred and twenty women participated in the study. Results. The mean age was 27.4 ± 3.4 years. One hundred nineteen women owned a cell phone and 114 (95%) had an email address. Seventy-two women (60%) had their gynecologist's cell phone number and 50 women (42%) had their family physician's cell phone number. More women contacted their gynecologist via cell phone or email during pregnancy compared to their family physician (P = 0.005 and 0.009, resp.). Most preferred to communicate with their physician via cell phone at predetermined times, but by email at any time during the day (P < 0.0001). They would use cell phones for emergencies or unusual problems but preferred email for other matters (P < 0.0001). Conclusions. Pregnant women in the Negev region do not have a preference between the use of cell phones or email for medical consultation with their gynecologist or family physician. The provision of the physician's cell phone numbers or email address together with the provision of guidelines and resources could improve healthcare services. PMID:25132848
Jiang, Kang; Ling, Feiyang; Feng, Zhongxiang; Wang, Kun; Guo, Lei
2017-02-17
As the prevalence of mobile phone use has increased globally, experts have verified the effects of mobile phone distraction on traffic safety. However, the psychological factors underlying pedestrians' decisions to use their mobile phones while crossing the street have received little attention. The present study employed the theory of planned behavior (TPB) to investigate the psychological factors that influence pedestrians' intentions to use a mobile phone while crossing the street. The additional predictors of descriptive norms, moral norms, risk perception, mobile phone involvement, and perceived ability to compensate are included. Approximately 40% of participants reported having used a mobile phone while crossing during the previous week and 5.4% had been involved in crossing accidents due to mobile phone distractions. Hierarchical multiple regression analyses revealed overall support for the predictive utility of the TPB. The standard TPB variables accounted for 13.3% of variance in intentions after demographic variables were controlled, and the extended predictors contributed an additional 7.6% beyond the standard constructs. The current study revealed that attitude, perceived behavior control, descriptive norms, mobile phone involvement, and perceived ability to compensate all emerged as significant predictors of intentions. The findings could support the design of more effective safety campaigns and interventions to reduce pedestrians' distracted crossing behaviors.
Online medicine for pregnant women.
Davidesko, Sharon; Segal, David; Peleg, Roni
2014-01-01
Objective. To assess the use of cell phones and email as means of communication between pregnant women and their gynecologists and family physicians. Study Design. A cross-sectional study of pregnant women at routine followup. One hundred and twenty women participated in the study. Results. The mean age was 27.4 ± 3.4 years. One hundred nineteen women owned a cell phone and 114 (95%) had an email address. Seventy-two women (60%) had their gynecologist's cell phone number and 50 women (42%) had their family physician's cell phone number. More women contacted their gynecologist via cell phone or email during pregnancy compared to their family physician (P = 0.005 and 0.009, resp.). Most preferred to communicate with their physician via cell phone at predetermined times, but by email at any time during the day (P < 0.0001). They would use cell phones for emergencies or unusual problems but preferred email for other matters (P < 0.0001). Conclusions. Pregnant women in the Negev region do not have a preference between the use of cell phones or email for medical consultation with their gynecologist or family physician. The provision of the physician's cell phone numbers or email address together with the provision of guidelines and resources could improve healthcare services.
Crisis Phones - Suicide Prevention Versus Suggestion/Contagion Effects.
Stack, Steven
2015-01-01
There has been no systematic work on the short- or long-term impact of the installation of crisis phones on suicides from bridges. The present study addresses this issue. Data refer to 219 suicides from 1954 through 2013 on the Skyway Bridge in St. Petersburg, Florida. Six crisis phones with signs were installed in July 1999. In the first decade after installation, the phones were used by 27 suicidal persons and credited with preventing 26 or 2.6 suicides a year. However, the net suicide count increased from 48 in the 13 years before installation of phones to 106 the following 13 years or by 4.5 additional suicides/year (t =3.512, p < .001). Although the phones prevented some suicides, there was a net increase after installation. The findings are interpreted with reference to suggestion/contagion effects including the emergence of a controversial bridge suicide blog.
NASA Astrophysics Data System (ADS)
Kotlyar, R.; Linton, T. D.; Rios, R.; Giles, M. D.; Cea, S. M.; Kuhn, K. J.; Povolotskyi, Michael; Kubis, Tillmann; Klimeck, Gerhard
2012-06-01
The hole surface roughness and phonon limited mobility in the silicon <100>, <110>, and <111> square nanowires under the technologically important conditions of applied gate bias and stress are studied with the self-consistent Poisson-sp3d5s*-SO tight-binding bandstructure method. Under an applied gate field, the hole carriers in a wire undergo a volume to surface inversion transition diminishing the positive effects of the high <110> and <111> valence band nonparabolicities, which are known to lead to the large gains of the phonon limited mobility at a zero field in narrow wires. Nonetheless, the hole mobility in the unstressed wires down to the 5 nm size remains competitive or shows an enhancement at high gate field over the large wire limit. Down to the studied 3 nm sizes, the hole mobility is degraded by strong surface roughness scattering in <100> and <110> wires. The <111> channels are shown to experience less surface scattering degradation. The physics of the surface roughness scattering dependence on wafer and channel orientations in a wire is discussed. The calculated uniaxial compressive channel stress gains of the hole mobility are found to reduce in the narrow wires and at the high field. This exacerbates the stressed mobility degradation with size. Nonetheless, stress gains of a factor of 2 are obtained for <110> wires down to 3 nm size at a 5×1012 cm-2 hole inversion density per gate area.
Physical, mechanical, and flexural properties of 3 orthodontic wires: an in-vitro study.
Juvvadi, Shubhaker Rao; Kailasam, Vignesh; Padmanabhan, Sridevi; Chitharanjan, Arun B
2010-11-01
Understanding the biologic requirements of orthodontic patients requires proper characterization studies of new archwire alloys. The aims of this study were to evaluate properties of wires made of 2 new materials and to compare their properties with those of stainless steel. The sample consisted of 30 straight lengths of 3 types of wires: stainless steel, titanium-molybdenum alloy, and beta-titanium alloy. Eight properties were evaluated: wire dimension, edge bevel, composition, surface characteristics, frictional characteristics, ultimate tensile strength (UTS), modulus of elasticity (E), yield strength (YS), and load deflection characteristics. A toolmaker's microscope was used to measure the edge bevel, and x-ray fluorescence was used for composition analysis. Surface profilometry and scanning electron microscopy were used for surface evaluation. A universal testing machine was used to evaluate frictional characteristics, tensile strength, and 3-point bending. Stainless steel was the smoothest wire; it had the lowest friction and spring-back values and high values for stiffness, E, YS, and UTS. The titanium-molybdenum alloy was the roughest wire; it had high friction and intermediate spring-back, stiffness, and UTS values. The beta-titanium alloy was intermediate for smoothness, friction, and UTS but had the highest spring-back. The beta-titanium alloy with increased UTS and YS had a low E value, suggesting that it would have greater resistance to fracture, thereby overcoming a major disadvantage of titanium-molybdenum alloy wires. The beta-titanium alloy wire would also deliver gentler forces. Copyright © 2010 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Vorobiev, Dmitry; Ninkov, Zoran
2017-11-01
Recent advances in photolithography allowed the fabrication of high-quality wire grid polarizers for the visible and near-infrared regimes. In turn, micropolarizer arrays (MPAs) based on wire grid polarizers have been developed and used to construct compact, versatile imaging polarimeters. However, the contrast and throughput of these polarimeters are significantly worse than one might expect based on the performance of large area wire grid polarizers or MPAs, alone. We investigate the parameters that affect the performance of wire grid polarizers and MPAs, using high-resolution two-dimensional and three-dimensional (3-D) finite-difference time-domain simulations. We pay special attention to numerical errors and other challenges that arise in models of these and other subwavelength optical devices. Our tests show that simulations of these structures in the visible and near-IR begin to converge numerically when the mesh size is smaller than ˜4 nm. The performance of wire grid polarizers is very sensitive to the shape, spacing, and conductivity of the metal wires. Using 3-D simulations of micropolarizer "superpixels," we directly study the cross talk due to diffraction at the edges of each micropolarizer, which decreases the contrast of MPAs to ˜200∶1.
Autostereoscopic display technology for mobile 3DTV applications
NASA Astrophysics Data System (ADS)
Harrold, Jonathan; Woodgate, Graham J.
2007-02-01
Mobile TV is now a commercial reality, and an opportunity exists for the first mass market 3DTV products based on cell phone platforms with switchable 2D/3D autostereoscopic displays. Compared to conventional cell phones, TV phones need to operate for extended periods of time with the display running at full brightness, so the efficiency of the 3D optical system is key. The desire for increased viewing freedom to provide greater viewing comfort can be met by increasing the number of views presented. A four view lenticular display will have a brightness five times greater than the equivalent parallax barrier display. Therefore, lenticular displays are very strong candidates for cell phone 3DTV. Selection of Polarisation Activated Microlens TM architectures for LCD, OLED and reflective display applications is described. The technology delivers significant advantages especially for high pixel density panels and optimises device ruggedness while maintaining display brightness. A significant manufacturing breakthrough is described, enabling switchable microlenses to be fabricated using a simple coating process, which is also readily scalable to large TV panels. The 3D image performance of candidate 3DTV panels will also be compared using autostereoscopic display optical output simulations.
Differences in the force system delivered by different beta-titanium wires in elaborate designs.
Martins, Renato Parsekian; Caldas, Sergei Godeiro Fernandes Rabelo; Ribeiro, Alexandre Antonio; Vaz, Luís Geraldo; Shimizu, Roberto Hideo; Martins, Lídia Parsekian
2015-01-01
Evaluation of the force system produced by four brands of b-Ti wires bent into an elaborate design. A total of 40 T-loop springs (TLS) hand-bent from 0.017 x 0.025-in b-Ti were randomly divided into four groups according to wire brand: TMATM(G1), BETA FLEXYTM (G2), BETA III WIRETM (G3) and BETA CNATM (G4). Forces and moments were recorded by a moment transducer, coupled to a digital extensometer indicator adapted to a testing machine, every 0.5 mm of deactivation from 5 mm of the initial activation. The moment-to-force (MF) ratio, the overlapping of the vertical extensions of the TLSs and the load-deflection (LD) ratio were also calculated. To complement the results, the Young's module (YM) of each wire was determined by the slope of the load-deflection graph of a tensile test. The surface chemical composition was also evaluated by an energy dispersive X-ray fluorescence spectrometer. All groups, except for G2, produced similar force levels initially. G3 produced the highest LD rates and G1 and G4 had similar amounts of overlap of the vertical extensions of the TLSs in "neutral position". G1 and G3 delivered the highest levels of moments, and G2 and G3 produced the highest MF ratios. b-Ti wires from G3 produced the highest YM and all groups showed similar composition, except for G2. The four beta-titanium wires analyzed produced different force systems when used in a more elaborate design due to the fact that each wire responds differently to bends.
Cheung, Melody; Lee, Wendy W Y; McCracken, John N; Larmour, Iain A; Brennan, Steven; Bell, Steven E J
2016-04-19
Raman analysis of dilute aqueous solutions is normally prevented by their low signal levels. A very general method to increase the concentration to detectable levels is to evaporate droplets of the sample to dryness, creating solid deposits which are then Raman probed. Here, superhydrophobic (SHP) wires with hydrophilic tips have been used as supports for drying droplets, which have the advantage that the residue is automatically deposited at the tip. The SHP wires were readily prepared in minutes using electroless galvanic deposition of Ag onto copper wires followed by modification with a polyfluorothiol (3,3,4,4,5,5,6,6,7,7,8,8,9,9,10,10,10-heptadecafluoro-1-decanethiol, HDFT). Cutting the coated wires with a scalpel revealed hydrophilic tips which could support droplets whose maximum size was determined by the wire diameter. Typically, 230 μm wires were used to support 0.6 μL droplets. Evaporation of dilute melamine droplets gave solid deposits which could be observed by scanning electron microscopy (SEM) and Raman spectroscopy. The limit of detection for melamine using a two stage evaporation procedure was 1 × 10(-6) mol dm(-3). The physical appearance of dried droplets of sucrose and glucose showed that the samples retained significant amounts of water, even under high vacuum. Nonetheless, the Raman detection limits of sucrose and glucose were 5 × 10(-4) and 2.5 × 10(-3) mol dm(-3), respectively, which is similar to the sensitivity reported for surface-enhanced Raman spectroscopy (SERS) detection of glucose. It was also possible to quantify the two sugars in mixtures at concentrations which were similar to those found in human blood through multivariate analysis.
Bogoch, Isaac I.; Andrews, Jason R.; Speich, Benjamin; Utzinger, Jürg; Ame, Shaali M.; Ali, Said M.; Keiser, Jennifer
2013-01-01
We created a mobile phone microscope and assessed its accuracy for the diagnosis of soil-transmitted helminths compared with conventional microscopy. Mobile phone microscopy has a sensitivity of 69.4% for detecting any helminth egg and sensitivities of 81.0%, 54.4%, and 14.3% for the diagnosis of Ascaris lumbricoides, Trichuris trichiura and hookworm respectively. PMID:23478580
Mobile phone use among motorcyclists and electric bike riders: A case study of Hanoi, Vietnam.
Truong, Long T; Nguyen, Hang T T; De Gruyter, Chris
2016-06-01
Motorcyclist injuries and fatalities are a major concern of many developing countries. In Vietnam, motorcycles are involved in more than 70% of all road traffic crashes. This paper aims to explore the prevalence and factors associated with mobile phone use among motorcyclists and electric bike riders, using a case study of Hanoi, Vietnam. A cross-sectional observation survey was undertaken at 12 sites, in which each site was surveyed during a two-hour peak period from 16:30 to 18:30 for two weekdays and one weekend day. A total of 26,360 riders were observed, consisting of 24,759 motorcyclists and 1601 electric bike riders. The overall prevalence of mobile phone use while riding was 8.4% (95% CI: 8.06-8.74%) with calling having higher prevalence than screen operation: 4.64% (95% CI: 4.39-4.90%) vs. 3.76% (95% CI: 3.52-3.99%) respectively. Moreover, the prevalence of mobile phone use was higher among motorcyclists than electric bike riders: 8.66% (95%CI: 8.30-9.01%) vs. 4.43% (95% CI: 3.40-5.47%) respectively. Logistic regression analyses revealed that mobile phone use while riding was associated with vehicle type, age, gender, riding alone, weather, day of week, proximity to city centre, number of lanes, separate car lanes, red traffic light duration, and police presence. Combining greater enforcement of existing legislations with extensive education and publicity programs is recommended to reduce potential deaths and injuries related to the use of mobile phones while riding. Copyright © 2016 Elsevier Ltd. All rights reserved.
Mobile Phone Ownership Is Not a Serious Barrier to Participation in Studies: Descriptive Study
Rubin, Leslie F; Smiley, Sabrina L; Zhou, Yitong; Elmasry, Hoda; Pearson, Jennifer L
2018-01-01
Background Rather than providing participants with study-specific data collection devices, their personal mobile phones are increasingly being used as a means for collecting geolocation and ecological momentary assessment (EMA) data in public health research. Objective The purpose of this study was to (1) describe the sociodemographic characteristics of respondents to an online survey screener assessing eligibility to participate in a mixed methods study collecting geolocation and EMA data via the participants’ personal mobile phones, and (2) examine how eligibility criteria requiring mobile phone ownership and an unlimited text messaging plan affected participant inclusion. Methods Adult (≥18 years) daily smokers were recruited via public advertisements, free weekly newspapers, printed flyers, and word of mouth. An online survey screener was used as the initial method of determining eligibility for study participation. The survey screened for twenty-eight inclusion criteria grouped into three categories, which included (1) cell phone use, (2) tobacco use, and (3) additional criteria Results A total of 1003 individuals completed the online screener. Respondents were predominantly African American (605/1003, 60.3%) (60.4%), male (514/1003, 51.3%), and had a median age of 35 years (IQR 26-50). Nearly 50% (496/1003, 49.5%) were unemployed. Most smoked menthol cigarettes (699/1003, 69.7%), and had a median smoking history of 11 years (IQR 5-21). The majority owned a mobile phone (739/1003, 73.7%), could install apps (86.8%), used their mobile phone daily (89.5%), and had an unlimited text messaging plan (871/1003, 86.8%). Of those who completed the online screener, 302 were eligible to participate in the study; 163 were eligible after rescreening, and 117 were enrolled in the study. Compared to employed individuals, a significantly greater proportion of those who were unemployed were ineligible for the study based on mobile phone inclusion criteria (P<.001); yet, 46.4% (333/717) of the individuals who were unemployed met all mobile phone inclusion criteria. Conclusions Inclusion criteria requiring participants to use their personal mobile phones for data collection was not a major barrier to study participation for most respondents who completed the online screener, including those who were unemployed. Trial Registration ClinicalTrials.gov NCT02261363; https://clinicaltrials.gov/ct2/show/NCT02261363 (Archived by WebCite at http://www.webcitation.org/6wOmDluSt) PMID:29459355
NASA Technical Reports Server (NTRS)
Williams, Martha; Roberson, Luke; Caraccio, Anne
2010-01-01
This viewgraph presentation describes new technologies in polymer and material chemistry that benefits NASA programs and missions. The topics include: 1) What are Polymers?; 2) History of Polymer Chemistry; 3) Composites/Materials Development at KSC; 4) Why Wiring; 5) Next Generation Wiring Materials; 6) Wire System Materials and Integration; 7) Self-Healing Wire Repair; 8) Smart Wiring Summary; 9) Fire and Polymers; 10) Aerogel Technology; 11) Aerogel Composites; 12) Aerogels for Oil Remediation; 13) KSC's Solution; 14) Chemochromic Hydrogen Sensors; 15) STS-130 and 131 Operations; 16) HyperPigment; 17) Antimicrobial Materials; 18) Conductive Inks Formulations for Multiple Applications; and 19) Testing and Processing Equipment.
Han, Yueh-Ying; Kano, Hideyuki; Davis, Devra L; Niranjan, Ajay; Lunsford, L Dade
2009-09-01
The capacity of radiofrequency from cell phones to be absorbed into the brain has prompted concerns that regular cell phone use may increase the risk of acoustic neuroma (AN) and other brain tumors. This article critically evaluates current literature on cell phone use and AN risks and proposes additional studies to clarify any possible linkage. Through a PubMed search, we identified and reviewed 10 case-control studies and 1 cohort study of AN risks associated with cell phone use and a meta-analysis of long-term mobile phone use and its association with AN and other brain tumors. Most studies did not find association between the development of AN and cell phone use, but some studies that followed cases for 10 years or more did show an association. Among 10 case-control studies, odds ratios for AN associated with regular cell phone use ranged from 0.5 (95% confidence interval [CI], 0.2-1.0) to 4.2 (95% CI, 1.8-10). Cell phone use was not associated with increased risk for AN in the Danish cohort study, which excluded business users from their study. The meta-analysis, which included 3 case-control studies, found that subjects who used cell phones for at least 10 years had a 2.4-fold greater risk of developing ipsilateral AN. In general, retrospective studies are limited in the ability to assess cell phone exposure because of recall bias and misclassification. The evaluation of AN risk factors is challenging due to its long latency. Some studies of longer term cell phone use have found an increased risk of ipsilateral AN. Adopting a prospective approach to acquire data on cell phone use, obtaining retrospective billing records that provide independent evaluations of exposures, and incorporating information on other key potential risk factors from questionnaires could markedly advance the capacity of studies to evaluate the impact of cell phones on AN.
Maeda, Tetsuo; Yamashita, Akira; Myojo, Yasuhiro; Wato, Yukihiro; Inaba, Hideo
2016-10-01
To investigate the impacts of emergency calls made using mobile phones on the quality of dispatcher-assisted cardiopulmonary resuscitation (DA-CPR) and survival from out-of-hospital cardiac arrests (OHCAs) that were not witnessed by emergency medical service (EMS). In this prospective study, we collected data for 2530 DA-CPR-attempted medical emergency cases (517 using mobile phones and 2013 using landline phones) and 2980 non-EMS-witnessed OHCAs (600 using mobile phones and 2380 using landline phones). Time factors and quality of DA-CPR, backgrounds of callers and outcomes of OHCAs were compared between mobile and landline phone groups. Emergency calls are much more frequently placed beside the arrest victim in mobile phone group (52.7% vs. 17.2%). The positive predictive value and acceptance rate of DA-CPR in mobile phone group (84.7% and 80.6%, respectively) were significantly higher than those in landline group (79.2% and 70.9%). The proportion of good-quality bystander CPR in mobile phone group was significantly higher than that in landline group (53.5% vs. 45.0%). When analysed for all non-EMS-witnessed OHCAs, rates of 1-month survival and 1-year neurologically favourable survival in mobile phone group (7.8% and 3.5%, respectively) were higher than those in landline phone group (4.6% and 1.9%; p<0.05). Multiple logistic regression analysis, including other backgrounds, revealed that mobile phone calls were associated with increased 1-month survival in the subgroup of OHCAs receiving bystander CPR (adjusted odds ratio, 1.84; 95% CI, 1.15-2.92). Emergency calls made using mobile phones are likely to augment the survival from OHCAs by improving DA-CPR. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Cooray, Charith; Matusevicius, Marius; Wahlgren, Nils; Ahmed, Niaz
2015-10-01
In many countries, a majority of stroke patients are not assessed for long-term functional outcome owing to limited resources and time. We investigated whether automatic assessment of the modified Rankin Scale (mRS) based on a mobile phone questionnaire may serve as an alternative to mRS assessments at clinical visits after stroke. We enrolled 62 acute stroke patients admitted to our stroke unit during March to May 2014. Forty-eight patients completed the study. During the stay, patients and/or caregivers were equipped with a mobile phone application in their personal mobile phones. The mobile phone application contained a set of 20 questions, based on the Rankin Focused Assessment, which we previously tested in a pilot study. Three months after inclusion, the mobile phone application automatically prompted the study participants to answer the mRS questionnaire in the mobile phones. Each question or a group of questions in the questionnaire corresponded to a certain mRS score. Using a predefined protocol, the highest mRS score question where the study participant had answered yes was deemed the final mobile mRS score. A few days later, a study personnel performed a clinical visit mRS assessment. The 2 assessments were compared using quadratic weighing κ-statistics. Mean age was 67 years (38% females), and median baseline National Institutes of Health Stroke Scale (NIHSS) score was 5 (interquartile range 2-10.5, range 0-23). Median and mean clinical visit mRS at 3 months was 2 and 2.3, respectively. We found a 62.5% agreement between clinical visit and mobile mRS assessment, weighted kappa 0.89 (95% confidence interval 0.82-0.96), and unweighted kappa 0.53 (95% confidence interval 0.36-0.70). Dichotomized mRS outcome separating functionally independent (mRS score 0-2) from dependent (mRS score 3-5) showed 83% agreement and unweighted kappa of 0.66 (95% confidence interval 0.45-0.87). Mobile phone-based automatic assessments of mRS performed well in comparison with clinical visit mRS and could be used as an alternative in stroke follow-up. © 2015 American Heart Association, Inc.
76 FR 39256 - Airworthiness Directives; Dassault Aviation Model FALCON 7X Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-06
... include modifying the applicable wiring and layout, a general visual inspection for absence of marks of... March 3, 2010. (2) Modify the applicable wiring and layout, in accordance with the Accomplishment... modifying the applicable wiring and layout, in accordance with Dassault Mandatory Service Bulletin 7X- 006...
Code of Federal Regulations, 2010 CFR
2010-07-01
... alloy steel chain, wire rope, metal mesh, natural or synthetic fiber rope (conventional three strand... steel chain sling or wire rope sling. (See Fig. N-184-3.) Mechanical coupling link is a nonwelded... Slings 6×19 and 6×37 Classification Improved Plow Steel Grade Rope With Independent Wire Rope Core (IWRC...
Code of Federal Regulations, 2011 CFR
2011-07-01
... alloy steel chain, wire rope, metal mesh, natural or synthetic fiber rope (conventional three strand... steel chain sling or wire rope sling. (See Fig. N-184-3.) Mechanical coupling link is a nonwelded... Slings 6×19 and 6×37 Classification Improved Plow Steel Grade Rope With Independent Wire Rope Core (IWRC...
14 CFR 121.1111 - Electrical wiring interconnection systems (EWIS) maintenance program.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Electrical wiring interconnection systems... Airworthiness and Safety Improvements § 121.1111 Electrical wiring interconnection systems (EWIS) maintenance program. (a) Except as provided in paragraph (f) of this section, this section applies to transport...
Influence of Wire Electrical Discharge Machining (WEDM) process parameters on surface roughness
NASA Astrophysics Data System (ADS)
Yeakub Ali, Mohammad; Banu, Asfana; Abu Bakar, Mazilah
2018-01-01
In obtaining the best quality of engineering components, the quality of machined parts surface plays an important role. It improves the fatigue strength, wear resistance, and corrosion of workpiece. This paper investigates the effects of wire electrical discharge machining (WEDM) process parameters on surface roughness of stainless steel using distilled water as dielectric fluid and brass wire as tool electrode. The parameters selected are voltage open, wire speed, wire tension, voltage gap, and off time. Empirical model was developed for the estimation of surface roughness. The analysis revealed that off time has a major influence on surface roughness. The optimum machining parameters for minimum surface roughness were found to be at a 10 V open voltage, 2.84 μs off time, 12 m/min wire speed, 6.3 N wire tension, and 54.91 V voltage gap.
Fabrication of multifilamentary Nb/sub 3/(Al,Ge) wires through a modified jelly roll process
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tachikawa, K.; Kamisada, Y.; Suzuki, E.
Recently, development of Nb/sub 3/Al multifilamentary wires has gained much interests since high-field performance superior to that of Nb/sub 3/Sn can be expected in these wires. In this study, Nb/Al-Ge alloy composites were fabricated into multifilamentary wires through a modified jelly roll (MJR) process. A Nb mesh sheet produced at the Teledyne Wah Chang Co. was used as Nb component. An Al-Ge alloy prepared by a conventional casting process was forged and rolled into a sheet of 0.2 mm in thickness. The Nb/Al-Ge composite was prepared by wrapping the Nb mesh sheet together with the Al-Ge alloy sheet around amore » Nb core into a jelly roll form. The MJR composite was encased in a Cu-Ni alloy tube of which outer diameter was 43 mm. The resulting composite was hydrostatically pressed and extruded into a rod of 18 mm in diameter. A Nb barrier was then inserted between the MJR and the Cu-Ni jacket. The composite rod was swaged and drawn into a wire without any intermediate annealing. The wire was able to be drawn down to a very small diameter of 0.1 mm. The cross-sectional configuration of the MJR composite was not much disturbed by the fabrication. Superconducting transition temperature Tc of the wire, after different heat treatment including a rapid quenching from high temperatures by a continuous electron beam irradiation, was studied, and an onset Tc of 19.3K has been achieved.« less
Effect of quasi-hydrostatical radial pressure on Ic of Nb3Sn wires
NASA Astrophysics Data System (ADS)
Mondonico, G.; Seeber, B.; Ferreira, A.; Bordini, B.; Oberli, L.; Bottura, L.; Ballarino, A.; Flükiger, R.; Senatore, C.
2012-11-01
High-performance Nb3Sn conductors are intended to be used in large-scale magnets like the International Thermonuclear Experimental Reactor (ITER) and in the upgrade of the Large Hadron Collider (LHC). Due to the occurrence of high electromagnetic forces, a detailed knowledge of the response of the critical current to the three-dimensional mechanical loads acting on the wires inside the cables is required. A detailed analysis of transverse stress effects on the critical current for powder-in-tube and bronze route Nb3Sn wires is presented. In an earlier publication, we have described the effect of transverse stress exerted on a Nb3Sn wire by means of two parallel plates. In the present paper, we analyse the effect of transverse stress exerted simultaneously by four walls on a wire being confined in a U-shaped groove. In order to get a more realistic picture of the situation of wires embedded in a Rutherford cable, the compression by four walls was also performed after impregnating the wire with epoxy in the same U-shaped groove. The result is very different from the case of pressing by means of two walls: the effect of pressure on Ic is now strongly reduced, which is attributed to the almost hydrostatic pressure in the U-shaped groove. This is further confirmed by the comparison between the effects of axial and transverse loads on the upper critical field and the pinning force. The present data are also compared against the effects of mechanical load on the critical current of cables in large-scale magnets.
Estimation of end of life mobile phones generation: the case study of the Czech Republic.
Polák, Miloš; Drápalová, Lenka
2012-08-01
The volume of waste electrical and electronic equipment (WEEE) has been rapidly growing in recent years. In the European Union (EU), legislation promoting the collection and recycling of WEEE has been in force since the year 2003. Yet, both current and recently suggested collection targets for WEEE are completely ineffective when it comes to collection and recycling of small WEEE (s-WEEE), with mobile phones as a typical example. Mobile phones are the most sold EEE and at the same time one of appliances with the lowest collection rate. To improve this situation, it is necessary to assess the amount of generated end of life (EoL) mobile phones as precisely as possible. This paper presents a method of assessment of EoL mobile phones generation based on delay model. Within the scope of this paper, the method has been applied on the Czech Republic data. However, this method can be applied also to other EoL appliances in or outside the Czech Republic. Our results show that the average total lifespan of Czech mobile phones is surprisingly long, exactly 7.99 years. We impute long lifespan particularly to a storage time of EoL mobile phones at households, estimated to be 4.35 years. In the years 1990-2000, only 45 thousands of EoL mobile phones were generated in the Czech Republic, while in the years 2000-2010 the number grew to 6.5 million pieces and it is estimated that in the years 2010-2020 about 26.3 million pieces will be generated. Current European legislation sets targets on collection and recycling of WEEE in general, but no specific collection target for EoL mobile phone exists. In the year 2010 only about 3-6% of Czech EoL mobile phones were collected for recovery and recycling. If we make similar estimation using an estimated average EU value, then within the next 10 years about 1.3 billion of EoL mobile phones would be available for recycling in the EU. This amount contains about 31 tonnes of gold and 325 tonnes of silver. Since Europe is dependent on import of many raw materials, efficient recycling of EoL products could help reduce this dependence. To set a working system of collection, it will be necessary to set new and realistic collection targets. Copyright © 2012 Elsevier Ltd. All rights reserved.
Improving sexually transmitted infection results notification via mobile phone technology.
Reed, Jennifer L; Huppert, Jill S; Taylor, Regina G; Gillespie, Gordon L; Byczkowski, Terri L; Kahn, Jessica A; Alessandrini, Evaline A
2014-11-01
To improve adolescent notification of positive sexually transmitted infection (STI) tests using mobile phone technology and STI information cards. A randomized intervention among 14- to 21-year olds in a pediatric emergency department (PED). A 2 × 3 factorial design with replication was used to evaluate the effectiveness of six combinations of two factors on the proportion of STI-positive adolescents notified within 7 days of testing. Independent factors included method of notification (call, text message, or call + text message) and provision of an STI information card with or without a phone number to obtain results. Covariates for logistic regression included age, empiric STI treatment, days until first attempted notification, and documentation of confidential phone number. Approximately half of the 383 females and 201 males enrolled were ≥18 years of age. Texting only or type of card was not significantly associated with patient notification rates, and there was no significant interaction between card and notification method. For females, successful notification was significantly greater for call + text message (odds ratio, 3.2; 95% confidence interval, 1.4-6.9), and documenting a confidential phone number was independently associated with successful notification (odds ratio, 3.6; 95% confidence interval, 1.7-7.5). We found no significant predictors of successful notification for males. Of patients with a documented confidential phone number who received a call + text message, 94% of females and 83% of males were successfully notified. Obtaining a confidential phone number and using call + text message improved STI notification rates among female but not male adolescents in a pediatric emergency department. Copyright © 2014 Society for Adolescent Health and Medicine. All rights reserved.
Symptoms and Cognitive Functions in Adolescents in Relation to Mobile Phone Use during Night
Schoeni, Anna; Roser, Katharina; Röösli, Martin
2015-01-01
Many adolescents tend to leave their mobile phones turned on during night, accepting that they may be awakened by an incoming text message or call. Using self-reported and objective operator recorded mobile phone use data, we thus aimed to analyze how being awakened during night by mobile phone affects adolescents’ perceived health and cognitive functions. In this cross-sectional study, 439 adolescents completed questionnaires about their mobile phone use during night, health related quality of life and possible confounding factors. Standardized computerized cognitive tests were performed to assess memory and concentration capacity. Objective operator recorded mobile phone use data was further collected for 233 study participants. Data were analyzed by multivariable regression models adjusted for relevant confounders including amount of mobile phone use. For adolescents reporting to be awakened by a mobile phone during night at least once a month the odds ratio for daytime tiredness and rapid exhaustibility were 1.86 (95% CI: 1.02–3.39) and 2.28 (95% CI: 0.97–5.34), respectively. Similar results were found when analyzing objective operator recorded mobile phone use data (tiredness: 1.63, 95% CI: 0.94–2.82 and rapid exhaustibility: 2.32, 95% CI: 1.01–5.36). The cognitive tests on memory and concentration capacity were not related to mobile phone use during night. Overall, being awakened during night by mobile phone was associated with an increase in health symptom reports such as tiredness, rapid exhaustibility, headache and physical ill-being, but not with memory and concentration capacity. Prevention strategies should focus on helping adolescents set limits for their accessibility by mobile phone, especially during night. PMID:26222312
Symptoms and Cognitive Functions in Adolescents in Relation to Mobile Phone Use during Night.
Schoeni, Anna; Roser, Katharina; Röösli, Martin
2015-01-01
Many adolescents tend to leave their mobile phones turned on during night, accepting that they may be awakened by an incoming text message or call. Using self-reported and objective operator recorded mobile phone use data, we thus aimed to analyze how being awakened during night by mobile phone affects adolescents' perceived health and cognitive functions. In this cross-sectional study, 439 adolescents completed questionnaires about their mobile phone use during night, health related quality of life and possible confounding factors. Standardized computerized cognitive tests were performed to assess memory and concentration capacity. Objective operator recorded mobile phone use data was further collected for 233 study participants. Data were analyzed by multivariable regression models adjusted for relevant confounders including amount of mobile phone use. For adolescents reporting to be awakened by a mobile phone during night at least once a month the odds ratio for daytime tiredness and rapid exhaustibility were 1.86 (95% CI: 1.02-3.39) and 2.28 (95% CI: 0.97-5.34), respectively. Similar results were found when analyzing objective operator recorded mobile phone use data (tiredness: 1.63, 95% CI: 0.94-2.82 and rapid exhaustibility: 2.32, 95% CI: 1.01-5.36). The cognitive tests on memory and concentration capacity were not related to mobile phone use during night. Overall, being awakened during night by mobile phone was associated with an increase in health symptom reports such as tiredness, rapid exhaustibility, headache and physical ill-being, but not with memory and concentration capacity. Prevention strategies should focus on helping adolescents set limits for their accessibility by mobile phone, especially during night.
Cell phone use while driving and attributable crash risk.
Farmer, Charles M; Braitman, Keli A; Lund, Adrian K
2010-10-01
Prior research has estimated that crash risk is 4 times higher when talking on a cell phone versus not talking. The objectives of this study were to estimate the extent to which drivers talk on cell phones while driving and to compute the implied annual number of crashes that could have been avoided if driver cell phone use were restricted. A national survey of approximately 1200 U.S. drivers was conducted. Respondents were asked to approximate the amount of time spent driving during a given day, number of cell phone calls made or received, and amount of driving time spent talking on a cell phone. Population attributable risk (PAR) was computed for each combination of driver gender, driver age, day of week, and time of day. These were multiplied by the corresponding crash counts to estimate the number of crashes that could have been avoided. On average, drivers were talking on cell phones approximately 7 percent of the time while driving. Rates were higher on weekdays (8%), in the afternoon and evening (8%), and for drivers younger than 30 (16%). Based on these use rates, restricting cell phones while driving could have prevented an estimated 22 percent (i.e., 1.3 million) of the crashes in 2008. Although increased rates of cell phone use while driving should be leading to increased crash rates, crash rates have been declining. Reasons for this paradox are unclear. One possibility is that the increase in cell phone use and crash risk due to cell phone use have been overestimated. Another possibility is that cell phone use has supplanted other driving distractions that were similarly hazardous.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thieme, C.L.H.; Kim, J.B.; Takayasu, M.
Critical current densities of multi-filamentary Nb{sub 3}Al wire made with the Jelly-Roll process (JR) and mono-core powder metallurgy process (PM) wire were measured as a function of temperature and magnetic field. The temperature dependence of the resistive critical field B{sub c2} was measured in PM wires. There is a significant difference between these resistive B{sub c2} values and the ones determined by Kramer plots. The field dependence of the critical current depends on the manufacturing method. In general, it follows a relationship that falls between pure Kramer and one where the pinning force is inversely proportional with B{sup 2}. Inmore » contrast with Nb{sub 3}Sn no maximum in the bulk pinning force is observed down to 3 T (0.15MxB{sub c2}).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dan’ko, S. A.; Mitrofanov, K. N., E-mail: mitrofan@triniti.ru; Krauz, V. I.
2015-11-15
Results of measurements of soft X-ray emission with photon energies of <1 keV under conditions of a plasma focus (PF) experiment are presented. The experiments were carried out at the world’s largest PF device—the PF-3 Filippov-type facility (I ⩽ 3 MA, T/4 ≈ 15–20 µs, W{sub 0} ⩽ 3 MJ). X-ray emission from both a discharge in pure neon and with a tungsten wire array placed on the axis of the discharge chamber was detected. The wire array imploded under the action of the electric current intercepted from the plasma current sheath of the PF discharge in neon. The measuredmore » soft X-ray powers from a conventional PF discharge in gas and a PF discharge in the presence of a wire array were compared for the first time.« less
Material and biofilm load of K wires in toe surgery: titanium versus stainless steel.
Clauss, Martin; Graf, Susanne; Gersbach, Silke; Hintermann, Beat; Ilchmann, Thomas; Knupp, Markus
2013-07-01
Recurrence rates for toe deformity correction are high and primarily are attributable to scar contractures. These contractures may result from subclinical infection. We hypothesized that (1) recurrence of toe deformities and residual pain are related to low-grade infections from biofilm formation on percutaneous K wires, (2) biofilm formation is lower on titanium (Ti) K wires compared with stainless steel (SS) K wires, and (3) clinical outcome is superior with the use of Ti K wires compared with SS K wires. In this prospective nonrandomized, comparative study, we investigated 135 lesser toe deformities (61 patients; 49 women; mean ± SD age, 60 ± 15 years) temporarily fixed with K wires between August 2010 and March 2011 (81 SS, 54 Ti). K wires were removed after 6 weeks. The presence of biofilm-related infections was analyzed by sonication. High bacterial loads (> 500 colony-forming units [CFU]/mL) were detected on all six toes requiring revision before 6 months. Increased bacterial load was associated with pain and swelling but not recurrence of the deformity. More SS K wires had greater than 100 CFU/mL bacteria than Ti K wires. For K wires with a bacterial count greater than 100 CFU/mL, toes with Ti K wires had a lower recurrence rate, less pain, and less swelling than toes with SS K wires. Ti K wires showed superior clinical outcomes to SS K wires. This appears to be attributable to reduced infection rates. Although additional study is needed, we currently recommend the use of Ti K wires for the transfixation of toe deformities. Level II, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Zhang, J; Jiang, X Y; Huang, X W
2016-06-18
To investigate the clinical efficacy and outcomes of two separate vertical wiring combined with tension band and Kirschner-wire plus cerclage wire in the treatment of displaced inferior pole fractures of the patella. From January 2013 to January 2015, 15 consecutive patients (mean age 54.5 years) with inferior pole fractures of the patella were retrospectively included in this study. All the patients underwent open reduction and internal fixation by separate vertical wiring combined with tension band and Kirschner-wire plus cerclage wire through longitudinal incision, 4.5 d (range: 3.1-5.9 d) after initial injury. A safety check for early knee range of motion was performed before wound closure. The complications including infection, nonunion, loss of fixation and any wire breakage or irritation from implant were recorded. Anteroposterior and lateral views of the knee joint obtained during the follow-up were used to assess bony union based on the time when the fracture line disappeared. At the time of the final outpatient follow up, functional evaluation of the knee joint was conducted by Bostman system. The follow-up time was 13.1 months (range: 12-19 months) after surgery on average, immediate motion without immobilization in all the cases was allowed and there was no case of reduction loss of the fracture and wire breakage. There was no case of irritation from the implant. At the final follow-up, the average range of motion (ROM) arc was 126.7° (range: 115°-140°), the average ROM lag versus contralateral healthy leg was 10.3° (range: 0°-35°). The mean Bostman score at the last follow-up was 28.9 (range: 27-30), and graded excellent in most cases. Two separate vertical wiring is an easy and effective method to reduce the displaced inferior pole fracture of patella. Augmentation of separate vertical wiring with tension band and Kirschner-wire plus cerclage wire in these patients provides enough strength to protected the early exercise of the knee joint and uneventful healing. By this surgical treatment, excellent results in knee function can be expected for cases of displaced inferior pole fractures of the patella.
Taherinia, Davood; Smith, Christopher E; Ghosh, Soumen; Odoh, Samuel O; Balhorn, Luke; Gagliardi, Laura; Cramer, Christopher J; Frisbie, C Daniel
2016-04-26
We report the synthesis, transport measurements, and electronic structure of conjugation-broken oligophenyleneimine (CB-OPI 6) molecular wires with lengths of ∼4 nm. The wires were grown from Au surfaces using stepwise aryl imine condensation reactions between 1,4-diaminobenzene and terephthalaldehyde (1,4-benzenedicarbaldehyde). Saturated spacers (conjugation breakers) were introduced into the molecular backbone by replacing the aromatic diamine with trans-1,4-diaminocyclohexane at specific steps during the growth processes. FT-IR and ellipsometry were used to follow the imination reactions on Au surfaces. Surface coverages (∼4 molecules/nm(2)) and electronic structures of the wires were determined by cyclic voltammetry and UV-vis spectroscopy, respectively. The current-voltage (I-V) characteristics of the wires were acquired using conducting probe atomic force microscopy (CP-AFM) in which an Au-coated AFM probe was brought into contact with the wires to form metal-molecule-metal junctions with contact areas of ∼50 nm(2). The low bias resistance increased with the number of saturated spacers, but was not sensitive to the position of the spacer within the wire. Temperature dependent measurements of resistance were consistent with a localized charge (polaron) hopping mechanism in all of the wires. Activation energies were in the range of 0.18-0.26 eV (4.2-6.0 kcal/mol) with the highest belonging to the fully conjugated OPI 6 wire and the lowest to the CB3,5-OPI 6 wire (the wire with two saturated spacers). For the two other wires with a single conjugation breaker, CB3-OPI 6 and CB5-OPI 6, activation energies of 0.20 eV (4.6 kcal/mol) and 0.21 eV (4.8 kcal/mol) were found, respectively. Computational studies using density functional theory confirmed the polaronic nature of charge carriers but predicted that the semiclassical activation energy of hopping should be higher for CB-OPI molecular wires than for the OPI 6 wire. To reconcile the experimental and computational results, we propose that the transport mechanism is thermally assisted polaron tunneling in the case of CB-OPI wires, which is consistent with their increased resistance.
Zbikowski, Susan M; Jack, Lisa M; McClure, Jennifer B; Deprey, Mona; Javitz, Harold S; McAfee, Timothy A; Catz, Sheryl L; Richards, Julie; Bush, Terry; Swan, Gary E
2011-05-01
Phone counseling has become standard for behavioral smoking cessation treatment. Newer options include Web and integrated phone-Web treatment. No prior research, to our knowledge, has systematically compared the effectiveness of these three treatment modalities in a randomized trial. Understanding how utilization varies by mode, the impact of utilization on outcomes, and predictors of utilization across each mode could lead to improved treatments. One thousand two hundred and two participants were randomized to phone, Web, or combined phone-Web cessation treatment. Services varied by modality and were tracked using automated systems. All participants received 12 weeks of varenicline, printed guides, an orientation call, and access to a phone supportline. Self-report data were collected at baseline and 6-month follow-up. Overall, participants utilized phone services more often than the Web-based services. Among treatment groups with Web access, a significant proportion logged in only once (37% phone-Web, 41% Web), and those in the phone-Web group logged in less often than those in the Web group (mean = 2.4 vs. 3.7, p = .0001). Use of the phone also was correlated with increased use of the Web. In multivariate analyses, greater use of the phone- or Web-based services was associated with higher cessation rates. Finally, older age and the belief that certain treatments could improve success were consistent predictors of greater utilization across groups. Other predictors varied by treatment group. Opportunities for enhancing treatment utilization exist, particularly for Web-based programs. Increasing utilization more broadly could result in better overall treatment effectiveness for all intervention modalities.
Improved 3D live-wire method with application to 3D CT chest image analysis
NASA Astrophysics Data System (ADS)
Lu, Kongkuo; Higgins, William E.
2006-03-01
The definition of regions of interests (ROIs), such as suspect cancer nodules or lymph nodes in 3D CT chest images, is often difficult because of the complexity of the phenomena that give rise to them. Manual slice tracing has been used widely for years for such problems, because it is easy to implement and guaranteed to work. But the manual method is extremely time-consuming, especially for high-solution 3D images which may have hundreds of slices, and it is subject to operator biases. Numerous automated image-segmentation methods have been proposed, but they are generally strongly application dependent, and even the "most robust" methods have difficulty in defining complex anatomical ROIs. To address this problem, the semi-automatic interactive paradigm referred to as "live wire" segmentation has been proposed by researchers. In live-wire segmentation, the human operator interactively defines an ROI's boundary guided by an active automated method which suggests what to define. This process in general is far faster, more reproducible and accurate than manual tracing, while, at the same time, permitting the definition of complex ROIs having ill-defined boundaries. We propose a 2D live-wire method employing an improved cost over previous works. In addition, we define a new 3D live-wire formulation that enables rapid definition of 3D ROIs. The method only requires the human operator to consider a few slices in general. Experimental results indicate that the new 2D and 3D live-wire approaches are efficient, allow for high reproducibility, and are reliable for 2D and 3D object segmentation.
NASA Astrophysics Data System (ADS)
Ikedo, Akihito; Kawashima, Takahiro; Kawano, Takeshi; Ishida, Makoto
2009-07-01
Repeated vapor-liquid-solid (VLS) growth with Au and PH3-Si2H6 mixture gas as the growth catalyst and silicon source, respectively, was used to construct n-type silicon/n-type silicon wire arrays of various lengths. Silicon wires of various lengths within an array could be grown by employing second growth over the first VLS grown wire. Additionally, the junction at the interface between the first and the second wires were examined. Current-voltage measurements of the wires exhibited linear behavior with a resistance of 850 Ω, confirming nonelectrical barriers at the junction, while bending tests indicated that the mechanical properties of the wire did not change.
2014-01-01
Background In 2012 mobile phone numbers were included into the ongoing New South Wales Population Health Survey (NSWPHS) using an overlapping dual-frame design. Previously in the NSWPHS the sample was selected using random digit dialing (RDD) of landline phone numbers. The survey was undertaken using computer assisted telephone interviewing (CATI). The weighting strategy needed to be significantly expanded to manage the differing probabilities of selection by frame, including that of children of mobile-only phone users, and to adjust for the increased chance of selection of dual-phone users. This paper describes the development of the final weighting strategy to properly combine the data from two overlapping sample frames accounting for the fact that population benchmarks for the different sampling frames were not available at the state or regional level. Methods Estimates of the number of phone numbers for the landline and mobile phone frames used to calculate the differing probabilities of selection by frame, for New South Wales (NSW) and by stratum, were obtained by apportioning Australian estimates as none were available for NSW. The weighting strategy was then developed by calculating person selection probabilities, selection weights, applying a constant composite factor to the dual-phone users sample weights, and benchmarking to the latest NSW population by age group, sex and stratum. Results Data from the NSWPHS for the first quarter of 2012 was used to test the weighting strategy. This consisted of data on 3395 respondents with 2171 (64%) from the landline frame and 1224 (36%) from the mobile frame. However, in order to calculate the weights, data needed to be available for all core weighting variables and so 3378 respondents, 2933 adults and 445 children, had sufficient data to be included. Average person weights were 3.3 times higher for the mobile-only respondents, 1.3 times higher for the landline-only respondents and 1.7 times higher for dual-phone users in the mobile frame compared to the dual-phone users in the landline frame. The overall weight effect for the first quarter of 2012 was 1.93 and the coefficient of variation of the weights was 0.96. The weight effects for 2012 were similar to, and in many cases less than, the effects found in the corresponding quarter of the 2011 NSWPHS when only a landline based sample was used. Conclusions The inclusion of mobile phone numbers, through an overlapping dual-frame design, improved the coverage of the survey and an appropriate weighing procedure is feasible, although it added substantially to the complexity of the weighting strategy. Access to accurate Australian, State and Territory estimates of the number of landline and mobile phone numbers and type of phone use by at least age group and sex would greatly assist in the weighting of dual-frame surveys in Australia. PMID:25189826
Barr, Margo L; Ferguson, Raymond A; Hughes, Phil J; Steel, David G
2014-09-04
In 2012 mobile phone numbers were included into the ongoing New South Wales Population Health Survey (NSWPHS) using an overlapping dual-frame design. Previously in the NSWPHS the sample was selected using random digit dialing (RDD) of landline phone numbers. The survey was undertaken using computer assisted telephone interviewing (CATI). The weighting strategy needed to be significantly expanded to manage the differing probabilities of selection by frame, including that of children of mobile-only phone users, and to adjust for the increased chance of selection of dual-phone users. This paper describes the development of the final weighting strategy to properly combine the data from two overlapping sample frames accounting for the fact that population benchmarks for the different sampling frames were not available at the state or regional level. Estimates of the number of phone numbers for the landline and mobile phone frames used to calculate the differing probabilities of selection by frame, for New South Wales (NSW) and by stratum, were obtained by apportioning Australian estimates as none were available for NSW. The weighting strategy was then developed by calculating person selection probabilities, selection weights, applying a constant composite factor to the dual-phone users sample weights, and benchmarking to the latest NSW population by age group, sex and stratum. Data from the NSWPHS for the first quarter of 2012 was used to test the weighting strategy. This consisted of data on 3395 respondents with 2171 (64%) from the landline frame and 1224 (36%) from the mobile frame. However, in order to calculate the weights, data needed to be available for all core weighting variables and so 3378 respondents, 2933 adults and 445 children, had sufficient data to be included. Average person weights were 3.3 times higher for the mobile-only respondents, 1.3 times higher for the landline-only respondents and 1.7 times higher for dual-phone users in the mobile frame compared to the dual-phone users in the landline frame. The overall weight effect for the first quarter of 2012 was 1.93 and the coefficient of variation of the weights was 0.96. The weight effects for 2012 were similar to, and in many cases less than, the effects found in the corresponding quarter of the 2011 NSWPHS when only a landline based sample was used. The inclusion of mobile phone numbers, through an overlapping dual-frame design, improved the coverage of the survey and an appropriate weighing procedure is feasible, although it added substantially to the complexity of the weighting strategy. Access to accurate Australian, State and Territory estimates of the number of landline and mobile phone numbers and type of phone use by at least age group and sex would greatly assist in the weighting of dual-frame surveys in Australia.
Wire-packed heat exchangers for dilution refrigerators.
Polturak, E; Rappaport, M; Rosenbaum, R
1978-03-01
Very simple wire-packed step heat exchangers for dilution refrigerators are described. No sintering is used in fabrication. Flow impedances and thermal resistance between the liquid and the copper wires are low. A refrigerator with five wire-packed heat exchangers in addition to a countercurrent heat exchanger attains a temperature of 11.4 mK with a single mixing chamber and 6.1 mK with two mixing chambers. High cooling power is achieved at modest (3)He circulation rates.
Composite ceramic superconducting wires for electric motor applications
NASA Astrophysics Data System (ADS)
Halloran, John W.
1990-07-01
Several types of HTSC wire have been produced and two types of HTSC motors are being built. Hundreds of meters of Ag- clad wire were fabricated from YBa2Cu3O(7-x) (Y-123) and Bi2Ca2Sr2Cu3O10 (BiSCCO). The dc homopolar motor coils are not yet completed, but multiple turns of wire have been wound on the coil bobbins to characterize the superconducting properties of coiled wire. Multifilamentary conductors were fabricated as cables and coils. The sintered polycrystalline wire has self-field critical current densities (Jc) as high as 2800 A/sq cm, but the Jc falls rapidly with magnetic field. To improve Jc, sintered YBCO wire is melt textured with a continuous process which has produced textures wire up to 0.5 meters long with 77K transport Jc above 11, 770 A/sq cm2 in self field and 2100 A/sq cm2 at 1 telsa. The Emerson Electric dc homopolar HTSC motor has been fabricated and run with conventional copper coils. A novel class of potential very powerful superconducting motors have been designed to use trapped flux in melt textures Y-123 as magnet replicas in an new type of permanent magnet motor. The stator element and part of the rotor of the first prototype machine exist, and the HTSC magnet replica segments are being fabricated.
SPM local oxidation nanolithography with active control of cantilever dynamics
NASA Astrophysics Data System (ADS)
Nishimura, S.; Takemura, Y.; Shirakashi, J.
2007-04-01
Local oxidation nanolithography using scanning probe microscope (SPM) has enabled us to fabricate nanometer-scale oxide wires on material surfaces. Here, we study tapping mode SPM local oxidation experiments for silicon by controlling the dynamic properties of the cantilever. Dependence of feature size of fabricated oxide wires on the amplitude of the cantilever was precisely investigated. The quality factor (Q) was fixed at a natural value of ~500. By enhancing the amplitude of the cantilever, both width and height of fabricated Si oxide wires were decreased. With the variation of the amplitude of the cantilever from 0.5 V to 3.0 V (DC voltage = 22.5 V, scanning speed = 20 nm/s), the feature size of Si oxide wires was well controlled, ranging from 40 nm to 18 nm in width and 2.3 nm to 0.6 nm in height. Standard deviation of width on Si oxide wires formed by tapping mode SPM is around 2.0 nm, which is smaller than that of contact mode Si oxide wires. Furthermore, the variation of the oscillation amplitude of the cantilever does not affect the size uniformity of the wires. These results imply that the SPM local oxidation nanolithography with active control of cantilever dynamics is a useful technique for producing higher controllability on the nanometer-scale fabrication of Si oxide wires.
A new venous infusion pathway monitoring system.
Maki, Hiromichi; Yonezawa, Yoshiharu; Ogawa, Hidekuni; Ninomiya, Ishio; Sata, Koji; Hamada, Shingo; Caldwell, W Morton
2007-01-01
A new infusion catheter pathway monitoring system employing linear integrated circuits and a low-power 8-bit single chip microcomputer has been developed for hospital and home use. The sensor consists of coaxial three-layer conductive tapes wrapped around the polyvinyl chloride infusion tube. The inner tape is the main electrode, which records an AC (alternating current) voltage induced on the patient's body by electrostatic coupling from the normal 100 volt, 60 Hz AC power line wiring field in the patient's room. The outside tape layer is a reference electrode to monitor the AC voltage around the main electrode. The center tape layer is connected to system ground and functions as a shield. The microcomputer calculates the ratio of the induced AC voltages recorded by the main and reference electrodes and if the ratio indicates a detached infusion, alerts the nursing station, via the nurse call system or low transmitting power mobile phone.
A new bed-exiting alarm system for welfare facility residents.
Ogawa, Hidekuni; Yonezawa, Yoshiharu; Maki, Hiromichi; Caldwell, W
2009-01-01
A newly developed alarm system detects welfare facility residents leaving their beds, and does not respond to the care staff, who wear shoes or slippers. It employs a stainless steel tape electrode, several linear integrated circuits and a low-power 8-bit single chip microcomputer. The electrode, which is used as a bed-exiting detection sensor, is attached to the floor mat to record changes in the always-present AC (alternating current) voltage induced on the patient's body by electrostatic coupling from the standard 100 volt, 60 Hz AC utility power wiring in the room walls and ceiling. The resident's body movements, before trying to get out of bed and after leaving the bed, are detected by the microcomputer from changes in the induced AC voltage. The microcomputer alerts the care staff station, via a power line communication system or PHS (personal handy phone System).
Capacitive touch sensing : signal and image processing algorithms
NASA Astrophysics Data System (ADS)
Baharav, Zachi; Kakarala, Ramakrishna
2011-03-01
Capacitive touch sensors have been in use for many years, and recently gained center stage with the ubiquitous use in smart-phones. In this work we will analyze the most common method of projected capacitive sensing, that of absolute capacitive sensing, together with the most common sensing pattern, that of diamond-shaped sensors. After a brief introduction to the problem, and the reasons behind its popularity, we will formulate the problem as a reconstruction from projections. We derive analytic solutions for two simple cases: circular finger on a wire grid, and square finger on a square grid. The solutions give insight into the ambiguities of finding finger location from sensor readings. The main contribution of our paper is the discussion of interpolation algorithms including simple linear interpolation , curve fitting (parabolic and Gaussian), filtering, general look-up-table, and combinations thereof. We conclude with observations on the limits of the present algorithmic methods, and point to possible future research.
Energy saving in data processing and communication systems.
Iazeolla, Giuseppe; Pieroni, Alessandra
2014-01-01
The power management of ICT systems, that is, data processing (Dp) and telecommunication (Tlc) systems, is becoming a relevant problem in economical terms. Dp systems totalize millions of servers and associated subsystems (processors, monitors, storage devices, etc.) all over the world that need to be electrically powered. Dp systems are also used in the government of Tlc systems, which, besides requiring Dp electrical power, also require Tlc-specific power, both for mobile networks (with their cell-phone towers and associated subsystems: base stations, subscriber stations, switching nodes, etc.) and for wired networks (with their routers, gateways, switches, etc.). ICT research is thus expected to investigate into methods to reduce Dp- and Tlc-specific power consumption. However, saving power may turn into waste of performance, in other words, into waste of ICT quality of service (QoS). This paper investigates the Dp and Tlc power management policies that look at compromises between power saving and QoS.
How to read and write mechanical information in DNA molecules
NASA Astrophysics Data System (ADS)
Schiessel, Helmut
In this talk I will show that DNA molecules contain another layer of information on top of the classical genetic information. This different type of information is of mechanical nature and guides the folding of DNA molecules inside cells. With the help of a new Monte Carlo technique, the Mutation Monte Carlo method, we demonstrate that the two layers of information can be multiplexed (as one can have two phone conversations on the same wire). For instance, we can guide on top of genes with single base-pair precision the packaging of DNA into nucleosomes. Finally, we study the mechanical properties of DNA molecules belonging to organisms all across the tree of life. From this we learn that in multicellular organisms the stiffness of DNA around transcription start sites differs dramatically from that of unicellular life. The reason for this difference is surprising.
Campbell, Robert J; Durigon, Louis
2003-01-01
Increasingly, health care professionals will need to retrieve, store, share, and send data using several types of wireless devices. These devices include personal digital assistants, laptops, Web tablets, cell phones, and clothing that monitor heart rate and blood pressure. Regardless of the device, several standards will vie for the right to provide the wireless communications link between the health care professional and the wired data resources located within a health care organization. This article identifies the top three technologies in the wireless communications field: Wireless Fidelity (WiFi), Mobile Communications, and Bluetooth; breaks down each according to its strengths and weaknesses; and makes recommendations for their use by health care professionals located inside and outside a health care facility. Where appropriate the discussion includes an explication of how a specific technology can be made secure from hackers and other security breeches.
Bedwick, Brian W; Garofoli, Gretchen K; Elswick, Betsy M
To evaluate the impact of an automated phone call by a pharmacy owner on the number of herpes zoster vaccinations given in the independent community pharmacy setting, compare herpes zoster immunization numbers in the 3 months during the previous year to the 3 months during the intervention, and assess patient satisfaction with the automated phone call service. This prospective study took place in an independent community pharmacy. A message was recorded by the pharmacy owner using a telephone-message program that notified patients aged 60 and older that the herpes zoster vaccine is recommended for them. This message was sent out monthly for a total of 3 months. Patients who received this vaccine in the 3 months following the initial phone call were surveyed to determine their reason for receiving the vaccine, and to assess satisfaction with the phone call. The total number of herpes zoster immunizations given at the pharmacy during the study period was compared to the total given at the pharmacy during the same period of the previous year. A total of 25 participants received the herpes zoster vaccine at the pharmacy during the study period, compared to 16 during the control period. Receiving the phone call was the most commonly cited reason for receiving the vaccine, followed by doctor recommendation. Of the 18 participants who received the call, 12 stated that they would be very likely to respond to similar phone calls in the future. These results demonstrate that using a targeted, automated phone call directed at eligible patients appears to have a positive effect on their willingness to receive the herpes zoster vaccine and may lead to an increase in vaccination numbers among eligible patients. Various factors must be considered before implementation of this service, including cost and added call volume. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
A comparison of wire- and Kevlar-reinforced provisional restorations.
Powell, D B; Nicholls, J I; Yuodelis, R A; Strygler, H
1994-01-01
Stainless steel wire 0.036 inch in diameter was compared with Kevlar 49 polyaramid fiber as a means of reinforcing a four-unit posterior provisional fixed restoration with 2 pontics. Three reinforcement patterns for wire and two for Kevlar 49 were evaluated and compared with the control, which was an unreinforced provisional restoration. A central tensile load was placed on the cemented provisional restoration and the variables were measured: (1) the initial stiffness; (2) the load at initial fracture; and (3) the unit toughness, or the energy stored in the beam at a point where the load had undergone a 1.0-mm deflection. Statistical analysis showed (1) the bent wire configuration had a significantly higher initial stiffness (P < or = .05), (2) there was no difference between designs for load at initial fracture, and (3) the bent wire had a significantly higher unit toughness value (P < or = .05).
Goedhart, Geertje; Vrijheid, Martine; Wiart, Joe; Hours, Martine; Kromhout, Hans; Cardis, Elisabeth; Eastman Langer, Chelsea; de Llobet Viladoms, Patricia; Massardier-Pilonchery, Amelie; Vermeulen, Roel
2015-10-01
A newly developed smartphone application was piloted to characterize and validate mobile phone use in young people. Twenty-six volunteers (mean age 17.3 years) from France, Spain, and the Netherlands used a software-modified smartphone for 4 weeks; the application installed on the phone recorded number and duration of calls, data use, laterality, hands-free device usage, and communication system used for both voice calls and data transfer. Upon returning the phone, participants estimated their mobile phone use during those 4 weeks via an interviewer-administered questionnaire. Results indicated that participants on average underestimated the number of calls they made, while they overestimated total call duration. Participants held the phone for about 90% of total call time near the head, mainly on the side of the head they reported as dominant. Some limitations were encountered when comparing reported and recorded data use and speaker use. When applied in a larger sample, information recorded by the smartphone application will be very useful to improve radiofrequency (RF) exposure modeling from mobile phones to be used in epidemiological research. © 2015 Wiley Periodicals, Inc.
Kararia, Vandana; Jain, Pradeep; Chaudhary, Seema; Kararia, Nitin
2015-01-01
Introduction: The biocompatibility of orthodontic dental alloys has been investigated over the past 20 years, but the results have been inconclusive. The study compares standard 3 M Unitek nickel-titanium (NiTi) and stainless steel archwires with locally available JJ orthodontics wires. Scanning electron microscope (SEM) study of surface changes and complexometric titration to study compositional change was performed. Materials and Methods: Ten archwires each of group 1–3 M 0.016” NiTi, group 2-JJ 0.016” NiTi, group 3–3 M 0.019” *0.025” SS and group 4-JJ SS contributed a 10 mm piece of wire for analysis prior to insertion in the patient and 6 weeks post insertion. SEM images were recorded at ×2000, ×4000 and ×6000 magnification. The same samples were subjected to complexiometric titration using ethylenediaminetetraacetic acid to gauge the actual change in the composition. Observations and Results: The SEM images of all the archwires showed marked changes with deep scratches and grooves and dark pitting corrosion areas post intraoral use. 3M wires showed an uniform criss-cross pattern in as received wires indicating a coating which was absent after intraoral use. There was a significant release of Nickel and Chromium from both group 3 and 4. Group 2 wires released ions significantly more than group 1 (P = 0.0). Conclusion: Extensive and stringent trials are required before certifying any product to be used in Orthodontics. PMID:25684911
Active Prompting to Decrease Cell Phone Use and Increase Seat Belt Use while Driving
ERIC Educational Resources Information Center
Clayton, Michael; Helms, Bridgett; Simpson, Cathy
2006-01-01
Automobile crashes are the leading cause of death for those aged 3 to 33, with 43,005 (118 per day) Americans killed in 2002 alone. Seat belt use reduces the risk of serious injury in an accident, and refraining from using a cell phone while driving reduces the risk of an accident. Cell phone use while driving increases accident rates, and leads…
Resources, Equipment and Logistics in Support of Long-Term Monitoring at Fort Benning
2005-08-01
access to cell phone transceivers for data retrieval. Sensor manufacturers, state climatologists, and the EPA provide standards, guidelines...have cell phone access for data retrieval and any software driven maintenance. Figure 3. Typical meteorological data acquisition station Sensor...collect and store data every 30 minutes. Of three current stations, one has a cell phone data link for daily retrieval. Table 2 lists equipment
An assessment of commercial motor vehicle driver distraction using naturalistic driving data.
Hickman, Jeffrey S; Hanowski, Richard J
2012-01-01
This study analyzed naturalistic driving data from commercial trucks (3-axle and tractor-trailer/tanker) and buses (transit and motorcoach) during a 3-month period. The data set contained 183 commercial truck and bus fleets comprising 13,306 vehicles and included 1085 crashes, 8375 near crashes, 30,661 crash-relevant conflicts, and 211,171 baseline events. Study results documented the prevalence of tertiary tasks and the risks associated with performing these tasks while driving. Results indicated the odds of involvement in a safety-critical event differed as a function of performing different cell phone-related subtasks while driving. Although the odds ratio for talking/listening on a cell phone while driving was found to not significantly increase the likelihood of involvement in a safety-critical event, other cell phone subtasks (e.g., texting, dialing, reaching) were found to significantly increase the odds of involvement in a safety-critical event. The results suggest that cell phone use while driving should not be considered a simple dichotomous task (yes/no). Consideration should instead be made for a set of discrete cell phone subtasks that are each associated with varying levels of risk. Several hypotheses are presented to explain why cell phone use while driving was found to not increase the likelihood of involvement in a safety-critical event.
Carlberg, Michael; Hardell, Lennart
2014-10-16
On 31 May 2011 the WHO International Agency for Research on Cancer (IARC) categorised radiofrequency electromagnetic fields (RF-EMFs) from mobile phones, and from other devices that emit similar non-ionising electromagnetic fields, as a Group 2B, i.e., a "possible", human carcinogen. A causal association would be strengthened if it could be shown that the use of wireless phones has an impact on the survival of glioma patients. We analysed survival of 1678 glioma patients in our 1997-2003 and 2007-2009 case-control studies. Use of wireless phones in the >20 years latency group (time since first use) yielded an increased hazard ratio (HR) = 1.7, 95% confidence interval (CI) = 1.2-2.3 for glioma. For astrocytoma grade IV (glioblastoma multiforme; n = 926) mobile phone use yielded HR = 2.0, 95% CI = 1.4-2.9 and cordless phone use HR = 3.4, 95% CI = 1.04-11 in the same latency category. The hazard ratio for astrocytoma grade IV increased statistically significant per year of latency for wireless phones, HR = 1.020, 95% CI = 1.007-1.033, but not per 100 h cumulative use, HR = 1.002, 95% CI = 0.999-1.005. HR was not statistically significant increased for other types of glioma. Due to the relationship with survival the classification of IARC is strengthened and RF-EMF should be regarded as human carcinogen requiring urgent revision of current exposure guidelines.
KIM-1 interface adapter to 3-wire teletype systems
NASA Technical Reports Server (NTRS)
Burhans, R. W.
1976-01-01
The KIM-1 circuit designed for use with a full duplex isolated 4 terminal system is described. Operation of the circuit with a 3 wire system in conjunction with a single +5v supply interface is discussed.
Mountain Plains Learning Experience Guide: Electrical Wiring. Course: Electrical Wiring Trim-Out.
ERIC Educational Resources Information Center
Arneson, R.; And Others
One of two individualized courses included in an electrical wiring curriculum, this course covers electrical materials installation for the trim-out stage. The course is comprised of five units: (1) Outlets, (2) Fixtures, (3) Switches, (4) Appliances, and (5) Miscellaneous. Each unit begins with a Unit Learning Experience Guide that gives…
46 CFR 162.017-3 - Materials, construction, and workmanship.
Code of Federal Regulations, 2011 CFR
2011-10-01
...-resistant wire mesh with a 1/2-inch corrosion-resistant separator on a single screen of 30×30 corrosion-resistant wire mesh shall be fitted on all openings to atmosphere. The net free area through the flame... are not acceptable. (e) Flame screens shall be made of corrosion-resistant wire. (f) Nonmetallic...
Effect of the Addition of 3% Co in NiTi Alloy on Loading/Unloading Force
NASA Astrophysics Data System (ADS)
Phukaoluan, A.; Dechkunakorn, S.; Anuwongnukroh, N.; Khantachawana, A.; Kaewtathip, P.; Kajornchaiyakul, J.; Wichai, W.
2017-11-01
The study evaluated the loading-unloading force in the load-deflection curve of the fabricated NiTiCo and NiTi wires. Wire alloys with Nickel, Titanium, and Cobalt (purity-99.95%) with atomic weight ratio 47Ni:50Ti:3Co and 50.6Ni:49.4Ti were prepared, sliced, and cold-rolled at 30% reduction, followed by heat treatment in a furnace at 400oC for 1 hour. The specimens of wire size of 0.016 x 0.022 inch2 were cut and subjected to three-point bending test to investigate the load-deflection curve at deflection point 0.25, 0.5, 0.75, 1.0, 1.25, and 1.5 mm. Descriptive statistic was used to evaluate each variables and independent t-test was used to compare between the groups. The results presented a load-deflection curve that resembled a typical superelastic wire. However, significant differences were seen in the loading-unloading forces between the two with an average loading force of 412.53g and 304.98g and unloading force of 292.40g and 208.08g for NiTiCo and NiTi wire, respectively. The force at each deflection point of NiTiCo in loading-unloading force was higher than NiTi wire. This study concluded that the addition of 3%Co in NiTi alloy can increase the loading-unloading force of NiTi wire but were within the range for orthodontic tooth movement.
Fournet, Alexandre; Boursier, Jean-François; Corbeau, Solène; Decambron, Adeline; Viateau, Véronique; Fayolle, Pascal; Bedu, Anne-Sophie; Leperlier, Dimitri; Manassero, Mathieu
2018-01-01
This article aimed to describe olecranon fracture in dogs and cats and their stabilization with tension band wiring or plate osteosynthesis, and to evaluate complications associated with each technique. Medical records of cats and dogs that had been surgically treated for olecranon fractures with either tension band wiring or plate osteosynthesis were retrospectively reviewed. The surgical technique, complications and long-term outcomes were assessed. Forty-one olecranon fractures were included. Fractures were articular, comminuted and open in 90, 31 and 27% of cases, respectively. Tension band wiring and plate osteosynthesis were performed in 22 and 19 fractures, respectively. Complications occurred more commonly after tension band wiring (74%) compared with plate osteosynthesis (27%) ( p = 0.002) and these were probably related to it being used in comminuted fractures ( p = 0.01) or to errors in technique. Minor complications included Kirschner wires migration ( n = 5), pain ( n = 3), osteomyelitis ( n = 3), skin breakdown ( n = 3) and seroma ( n = 1). Implant failure requiring further fixation ( n = 4) was observed only in the tension band wiring group. Other major complications included skin wound debridement and closure ( n = 1) and chronic lameness requiring implant removal ( n = 7). Long-term functional outcomes were excellent regardless of the technique used. Plate osteosynthesis should be performed for olecranon fracture repair if technically feasible. Schattauer GmbH Stuttgart.
Transport of energy by ultraintense laser-generated electrons in nail-wire targets
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma, T.; Lawrence Livermore National Laboratory, Livermore, California 94550; Key, M. H.
2009-11-15
Nail-wire targets (20 {mu}m diameter copper wires with 80 {mu}m hemispherical head) were used to investigate energy transport by relativistic fast electrons generated in intense laser-plasma interactions. The targets were irradiated using the 300 J, 1 ps, and 2x10{sup 20} W{center_dot}cm{sup -2} Vulcan laser at the Rutherford Appleton Laboratory. A spherically bent crystal imager, a highly ordered pyrolytic graphite spectrometer, and single photon counting charge-coupled device gave absolute Cu K{alpha} measurements. Results show a concentration of energy deposition in the head and an approximately exponential fall-off along the wire with about 60 {mu}m 1/e decay length due to resistive inhibition.more » The coupling efficiency to the wire was 3.3{+-}1.7% with an average hot electron temperature of 620{+-}125 keV. Extreme ultraviolet images (68 and 256 eV) indicate additional heating of a thin surface layer of the wire. Modeling using the hybrid E-PLAS code has been compared with the experimental data, showing evidence of resistive heating, magnetic trapping, and surface transport.« less
Quek, June; Brauer, Sandra G; Treleaven, Julia; Pua, Yong-Hao; Mentiplay, Benjamin; Clark, Ross Allan
2014-04-17
Concurrent validity and intra-rater reliability using a customized Android phone application to measure cervical-spine range-of-motion (ROM) has not been previously validated against a gold-standard three-dimensional motion analysis (3DMA) system. Twenty-one healthy individuals (age:31 ± 9.1 years, male:11) participated, with 16 re-examined for intra-rater reliability 1-7 days later. An Android phone was fixed on a helmet, which was then securely fastened on the participant's head. Cervical-spine ROM in flexion, extension, lateral flexion and rotation were performed in sitting with concurrent measurements obtained from both a 3DMA system and the phone.The phone demonstrated moderate to excellent (ICC = 0.53-0.98, Spearman ρ = 0.52-0.98) concurrent validity for ROM measurements in cervical flexion, extension, lateral-flexion and rotation. However, cervical rotation demonstrated both proportional and fixed bias. Excellent intra-rater reliability was demonstrated for cervical flexion, extension and lateral flexion (ICC = 0.82-0.90), but poor for right- and left-rotation (ICC = 0.05-0.33) using the phone. Possible reasons for the outcome are that flexion, extension and lateral-flexion measurements are detected by gravity-dependent accelerometers while rotation measurements are detected by the magnetometer which can be adversely affected by surrounding magnetic fields. The results of this study demonstrate that the tested Android phone application is valid and reliable to measure ROM of the cervical-spine in flexion, extension and lateral-flexion but not in rotation likely due to magnetic interference. The clinical implication of this study is that therapists should be mindful of the plane of measurement when using the Android phone to measure ROM of the cervical-spine.
2014-01-01
Background Concurrent validity and intra-rater reliability using a customized Android phone application to measure cervical-spine range-of-motion (ROM) has not been previously validated against a gold-standard three-dimensional motion analysis (3DMA) system. Findings Twenty-one healthy individuals (age:31 ± 9.1 years, male:11) participated, with 16 re-examined for intra-rater reliability 1–7 days later. An Android phone was fixed on a helmet, which was then securely fastened on the participant’s head. Cervical-spine ROM in flexion, extension, lateral flexion and rotation were performed in sitting with concurrent measurements obtained from both a 3DMA system and the phone. The phone demonstrated moderate to excellent (ICC = 0.53-0.98, Spearman ρ = 0.52-0.98) concurrent validity for ROM measurements in cervical flexion, extension, lateral-flexion and rotation. However, cervical rotation demonstrated both proportional and fixed bias. Excellent intra-rater reliability was demonstrated for cervical flexion, extension and lateral flexion (ICC = 0.82-0.90), but poor for right- and left-rotation (ICC = 0.05-0.33) using the phone. Possible reasons for the outcome are that flexion, extension and lateral-flexion measurements are detected by gravity-dependent accelerometers while rotation measurements are detected by the magnetometer which can be adversely affected by surrounding magnetic fields. Conclusion The results of this study demonstrate that the tested Android phone application is valid and reliable to measure ROM of the cervical-spine in flexion, extension and lateral-flexion but not in rotation likely due to magnetic interference. The clinical implication of this study is that therapists should be mindful of the plane of measurement when using the Android phone to measure ROM of the cervical-spine. PMID:24742001
Thomas, Silke; Heinrich, Sabine; Kühnlein, Anja; Radon, Katja
2010-01-01
A potential association between socioeconomic status (SES) and self-reported use of mobile phones has been investigated in a few studies. If measured exposure to mobile phone networks differs by SES in children, it has not yet been studied. Interview data of 1,481 children and 1,505 adolescents on participants' mobile phone use, socio-demographic characteristics and potential confounders were taken from the German MobilEe-study. Sociodemographic data was used to stratify participants into three "status groups" (low, middle, high). Using a personal dosimeter, we obtained an exposure profile over 24 h for each of the participants. Exposure levels during waking hours were expressed as mean percentage of the reference level. Children with a low SES were more likely to own a mobile phone (OR 2.1; 95% CI: 1.1-3.9) and also reported to use their mobile phone longer per day (OR 2.4; 95% CI: 1.1-5.4) than children with a high SES. For adolescents, self-reported duration of mobile phone use per day was also higher with a low SES (OR: 3.4; 95% CI: 1.4-8.4) compared with a high SES. No association between SES and measured exposure to mobile telecommunication networks was seen for children or adolescents. Mobile phone use may differ between status groups with higher use among disadvantaged groups. However, this does not result in higher overall exposure to mobile telecommunication networks. Whether short duration of own mobile phone use or the small numbers of participants with a low SES are causal, have to be investigated in further studies. (c) 2009 Wiley-Liss, Inc.
Mobile phones and seizures: drug-resistant epilepsy is less common in mobile-phone-using patients.
Nagarjunakonda, Sundarachary; Amalakanti, Sridhar; Uppala, Veeramma; Gajula, Rama Krishna; Tata, Ramya Sree; Bolla, Hima Bindu; Rajanala, Lalitha; Athina, Srinivasulu; Daggumati, Rajeswari; Lavu, Harish; Devanaboina, Anil Kumar
2017-01-01
Epilepsy is a condition where patients have seizures due to abnormal nerve impulses in the brain. The effect of mobile phone radiation on patients with seizures is not known. To compare the seizure profile of patients not using mobile phones with that of their peers using mobile phones. In a retrospective cohort study performed at the neurology outpatient department of Guntur Medical College Hospital, Guntur, India from September 2014 to September 2015, we included 178 consecutive epileptic patients aged 16-65 years, who had had seizure disorder for 1 year or more. On the basis of their possession and usage of mobile phones, patients were divided into three groups: no mobile group (NMG), home mobile group (HMG) and personal mobile group (PMG). We obtained data on seizure frequency and recorded details of mobile phone usage and their antiepileptic drug (AED) treatment. 107 NMG, 3 HMG and 68 PMG patients were finalised for the analysis. There was no significant difference in the number of seizures in the past year between the three groups. The PMG (3.7%) contained a clinically significant lower proportion of patients with drug-resistant epilepsy than the NMG (28.2%). Patients with drug-responsive epilepsy were 7.4 (95% CI 1.4 to 39.9) (p=0.01) times more likely to be found in the PMG than in the NMG after adjustment for differences in sex and occupation. Although the experimental data remain inconclusive, our clinical study suggests that patients who use mobile phones are less likely to have drug-resistant epilepsy. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Comparative range of orthodontic wires.
Ingram, S B; Gipe, D P; Smith, R J
1986-10-01
ADA specification No. 32 for determining the range (elastic limit) of orthodontic wires uses the bending of a wire section treated as a cantilever beam. An alternative method for defining the range of orthodontic wires proposed by Waters (1981) is to wrap wire sections around mandrels of varying diameters and measure the deformation imparted after unwrapping. Four brass mandrels with a total of 46 test diameters ranging from 3.5 to 60.0 mm were used in this study. Wire sections 9 cm in length were rolled on the mandrel with a hand lathe. The mandrel cross section required to produce a predetermined amount of deformation (2 mm arc height for a 5 cm chord) was defined as the yield diameter for that particular wire. No individual wire was tested twice so as to avoid introduction of strain history. Test samples of 488 different orthodontic wires supplied by nine commercial distributors were evaluated (a total of 4,747 samples). Stainless steel wires of identical dimensions had a large variation in range, depending on the state of strain hardening and heat treatment. For example, 0.020 inch round wire had yield diameters ranging from 22.8 mm for Australian special plus orange (TP Laboratories) to 42.9 mm for Nubryte gold (G.A.C. International). Chromium cobalt wires had less range than stainless steel before heat treatment, but increased greatly in range after heat treatment. Nitinol (Unitek) had the greatest range of all wires tested (yield diameter of 8.7 mm for 0.016 inch Nitinol). Multistranded stainless steel wires had yield diameters between 9.0 and 14.0 mm.
Pressure Measurements for Tungsten Wire Explosions in Water
NASA Astrophysics Data System (ADS)
Afanas'ev, V. N.
2005-07-01
Successful wire array implosion experiments carried out on PBFA- Z accelerator [1], in which a record-breaking soft x-ray yield of more than 1.5 MJ was observed, stimulated interest in research of electric explosion of thin metal wires. The results of pressure measurements micron's tungsten wire explosion, which carried out in deionized water. Thin tungsten wire explosion was investigated experimentally at current pulse 100 ns duration. The shock waves from the 70 μm tungsten wire explosion were measured by the piezoceramic pressure gauge. The gauges were placed at a range from 3 to 15 mm of wire. The piezoceramic gauges were calibrated on the stable electron beams generator with nanoseconds duration. Experiments were carried out for verifying the tungsten plasma equation of state parameters under different values of the deposited energy. [1] R. B. Spielman, C. Deeney, G. A. Chandler et al., Phys.Plasmas #5, ð. 2105, 1998. The work was supported by ISTC # 1826
NASA Astrophysics Data System (ADS)
Kim, Jun-Hyun; Bak, Jeong Geun; Lee, Kangtaek; Kim, Chang-Koo
2018-01-01
Control of the electrical resistivity of Ni-Cr wires is demonstrated using low pressure chemical vapor deposition (LPCVD) of tin on the surface of the wire, after which the effects of the deposition temperature on the structural, morphological, and compositional characteristics of the tin-deposited Ni-Cr wires are investigated. As the deposition temperature is increased, the resistivity of the Ni-Cr wires increases in the temperature range 300-400 °C; then remains nearly constant as the temperature increased to 700 °C. The increase in the resistivity of the Ni-Cr wires is attributed to formation of Ni3Sn2 particulates on the surface of the wire. Compositional analysis shows that the pattern of change in the tin content with the deposition temperature is similar to that of resistivity with temperature, implying that the atomic content of tin on Ni-Cr directly affects the electrical resistivity.
Present status of PIT round wires of 122-type iron-based superconductors
NASA Astrophysics Data System (ADS)
Tamegai, T.; Suwa, T.; Pyon, S.; Kajitani, H.; Takano, K.; Koizumi, N.; Awaji, S.; Watanabe, K.
2017-12-01
Outstanding characteristics with high T c and H c2 and small anisotropy in iron-based superconductors (IBSs) have triggered the development of superconducting wires and tapes using these novel superconductors. In this short article, developments and present status of round wires of 122-type IBSs are reviewed. By introducing hot-isostatic pressing (HIP) technique, J c in round wires of 122-type IBSs has been improved significantly. Further improvements have been realized by refining the fabrication process of the core material and introducing partial texturing of the wire core. The largest transport J c for round wires at 4.2 K at self-field and 100 kOe are 2.0x105 A/cm2 and 3.8x104 A/cm2, respectively. We also compare the J c characteristics of wires and tapes processed by HIP.
Three dimensional interactive display
NASA Technical Reports Server (NTRS)
Vranish, John M. (Inventor)
2005-01-01
A three-dimensional (3-D) interactive display and method of forming the same, includes a transparent capaciflector (TC) camera formed on a transparent shield layer on the screen surface. A first dielectric layer is formed on the shield layer. A first wire layer is formed on the first dielectric layer. A second dielectric layer is formed on the first wire layer. A second wire layer is formed on the second dielectric layer. Wires on the first wire layer and second wire layer are grouped into groups of parallel wires with a turnaround at one end of each group and a sensor pad at the opposite end. An operational amplifier is connected to each of the sensor pads and the shield pad biases the pads and receives a signal from connected sensor pads in response to intrusion of a probe. The signal is proportional to probe location with respect to the monitor screen.
48 CFR 750.7110-3 - Submission of cases to the M/OP Director.
Code of Federal Regulations, 2013 CFR
2013-10-01
...) Date of request; (2) Date request received by USAID: (3) Contract number; (4) Contractor's name and address; (5) Name, address, and phone number of contractor's representative; (6) Name, office symbol, and phone number of cognizant contracting officer; (7) Amount of request. [62 FR 40469, July 29, 1997, as...
48 CFR 750.7110-3 - Submission of cases to the M/OP Director.
Code of Federal Regulations, 2014 CFR
2014-10-01
...) Date of request; (2) Date request received by USAID: (3) Contract number; (4) Contractor's name and address; (5) Name, address, and phone number of contractor's representative; (6) Name, office symbol, and phone number of cognizant contracting officer; (7) Amount of request. [62 FR 40469, July 29, 1997, as...
48 CFR 750.7110-3 - Submission of cases to the M/OP Director.
Code of Federal Regulations, 2012 CFR
2012-10-01
...) Date of request; (2) Date request received by USAID: (3) Contract number; (4) Contractor's name and address; (5) Name, address, and phone number of contractor's representative; (6) Name, office symbol, and phone number of cognizant contracting officer; (7) Amount of request. [62 FR 40469, July 29, 1997, as...
Comparisons of nanoindentation, 3-point bending, and tension tests for orthodontic wires.
Iijima, Masahiro; Muguruma, Takeshi; Brantley, William A; Mizoguchi, Itaru
2011-07-01
The purposes of this study were to obtain information about mechanical properties with the nanoindentation test for representative wire alloys and compare the results with conventional mechanical tests. Archwires having 0.016 × 0.022-in cross sections were obtained of 1 stainless steel, 1 cobalt-chromium-nickel, 1 beta-titanium alloy, and 2 nickel-titanium products. Specimens of as-received wires were subjected to nanoindentation testing along the external surfaces and over polished cross sections to obtain values of hardness and elastic modulus. Other specimens of as-received wires were subjected to Vickers hardness, 3-point bending, and tension tests. All testing was performed at 25°C. Differences were found in hardness and elastic modulus obtained with the nanoindentation test at the external and cross-sectioned surfaces and with the conventional mechanical-property tests. Mechanical properties obtained with the nanoindentation test generally varied with indentation depth. The 3 testing methods did not yield identical values of hardness and elastic modulus, although the order among the 5 wire products was the same. Variations in results for the nanoindentation and conventional mechanical property tests can be attributed to the different material volumes sampled, different work-hardening levels, and an oxide layer on the wire surface. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
Wire-Cell Tomographic Event Reconstruction for large LArTPCs
NASA Astrophysics Data System (ADS)
Qian, Xin; Viren, Brett; Zhang, Chao; Wire-Cell Team
2016-03-01
Event reconstruction is one of the most challenging tasks in analyzing the data from current and future large liquid argon time projection chambers (LArTPCs). The performance of the event reconstruction holds the key to many potential future discoveries with the LArTPC technology including i) searching for new CP violation in the leptonic sector, ii) determining the neutrino mass hierarchy, and iii) searching for additional light (sterile) neutrino species. In this talk, we introduce a new reconstruction method: Wire-Cell. The principle of Wire-Cell strictly follows the principle of LArTPC, that is, the same amount of ionization electrons are observed by all the wire-planes. Using both time and charge information, 3D image of the event topologies are firstly obtained. Further reconstruction steps including the clustering, tracking, and particle identifications (PID) are then directly applied to the 3D image. The principle, current status, and future development plan of Wire-Cell will be described. The results of Wire-Cell event reconstruction will be shown with an innovative web-based ``BEE'' 3D event display. This work is supported by U.S. Department of Energy, Office of Science, Office of High Energy Physics and Early Career Research program under Contract Number DE-SC0012704.
Semi-automatic central-chest lymph-node definition from 3D MDCT images
NASA Astrophysics Data System (ADS)
Lu, Kongkuo; Higgins, William E.
2010-03-01
Central-chest lymph nodes play a vital role in lung-cancer staging. The three-dimensional (3D) definition of lymph nodes from multidetector computed-tomography (MDCT) images, however, remains an open problem. This is because of the limitations in the MDCT imaging of soft-tissue structures and the complicated phenomena that influence the appearance of a lymph node in an MDCT image. In the past, we have made significant efforts toward developing (1) live-wire-based segmentation methods for defining 2D and 3D chest structures and (2) a computer-based system for automatic definition and interactive visualization of the Mountain central-chest lymph-node stations. Based on these works, we propose new single-click and single-section live-wire methods for segmenting central-chest lymph nodes. The single-click live wire only requires the user to select an object pixel on one 2D MDCT section and is designed for typical lymph nodes. The single-section live wire requires the user to process one selected 2D section using standard 2D live wire, but it is more robust. We applied these methods to the segmentation of 20 lymph nodes from two human MDCT chest scans (10 per scan) drawn from our ground-truth database. The single-click live wire segmented 75% of the selected nodes successfully and reproducibly, while the success rate for the single-section live wire was 85%. We are able to segment the remaining nodes, using our previously derived (but more interaction intense) 2D live-wire method incorporated in our lymph-node analysis system. Both proposed methods are reliable and applicable to a wide range of pulmonary lymph nodes.
Fujita, Masaru; Diab, Mohammad; Xu, Zheng; Puttlitz, Christian M
2006-09-01
An in vitro biomechanical calf thoracic spine study. To evaluate the biomechanical stability of sublaminar and subtransverse process fixation using stainless steel wires and ultra-high molecular weight polyethylene (UHMWPE) cables. It is commonly held that transverse process fixation provides less stability than sublaminar fixation. To our knowledge, this is the first biomechanical study to compare the stability afforded by sublaminar fixation and subtransverse process fixation using metal wire and UHMWPE cable before and after cyclic loading. There were 6 fresh-frozen calf thoracic spines (T4-T9) used to determine the sublaminar fixation stiffness and subtransverse process fixation stiffness in each group. Double strands of 18-gauge stainless steel wire, 3 and 5 mm-width UHMWPE cable (Nesplon; Alfresa, Inc., Osaka, Japan) were applied to each spine. Cyclic pure flexion-extension moment loading (2 Nm, 0.5 Hz, 5000 cycles) was applied after the initial stability was analyzed by measuring the range of motion. Statistical analyses were used to delineate differences between the various experimental groups. Subtransverse process wiring was more stable than sublaminar wiring after cyclic loading in flexion-extension (P < 0.05). There were no significant differences between each group in lateral bending and axial rotation after cyclic loading. Sublaminar stainless steel wiring was more stable than sublaminar 3 and 5-mm cable before and after cyclic loading in axial rotation (P < 0.01). Acute subtransverse process fixation using 3-mm cable was less stable after cyclic loading in axial rotation (P < 0.05). All other groups did not produce statistically significant differences. Subtransverse process fixation provides at least as much stability as sublaminar fixation. A 5-mm UHMWPE cable and stainless steel wire result in equivalent sublaminar and subtransverse process stability.
Nalbantgil, Didem; Ulkur, Feyza; Kardas, Gulfeza; Culha, Mustafa
2016-11-25
Patients use mouthwashes in addition to mechanical cleaning during orthodontic treatment. The effects of mouthwashes on the archwires have not been examined yet. To compare the corrosion resistance of four different arch wires and corrosion effects of different mouthwashes to formulate a biocompatible and mechanically useful arch wire and mouthwash combination. Each group comprised of 4 wire samples of 2 cm 0.016 × 0.022 inch. 1st group: ion implanted nickel titanium (INT), 2nd group: nickel titanium, without ion implantation (NT), 3rd group: micro layered esthetic nickel titanium (ENT), 4th group: stainless steel (SS) wires. They were immersed inside 2 ml of artificial saliva solutions (AS) for the control, or AS (9%) combined with 1 of the 3 mouthwashes (91%) for study groups, for 24 hours. These mouthwashes were essential oil (EO), chlorhexidine (CHX), sodium-fluoride (NaF). An electrochemical analyzer was used for electrochemical impedance spectroscopy measurements. High corrosion resistance was obtained for ENT than the other wires. The corrosion potentials are 0.007, -0.042, 0.074 and -0.015 V (Ag/AgCl) for ENT, INT, SS and NT in the artificial salivary, respectively. In NaF containing mouthwash Rp value of ENT is significantly high in comparison to others. The impedance responses of all materials increased significantly in the presence of NaF mouthwash as well as in the CHX mouthwash. Low frequencies are seen at all materials in EO mouthwash. Diameters of loops are 22, 5.9, 5.9 and 3.7 MΩ at ENT, INT, SS and NT. In this study, micro layered esthetic nickel titanium wires are found biocompatible among other wires and NaF and CHX mouthwashes can be recommend for their good corrosion resistance during fixed orthodontic therapy.
The drop it at last study: six-month results of a phone-based weight loss trial.
Sherwood, Nancy E; Jeffery, Robert W; Welsh, Ericka M; Vanwormer, Jeff; Hotop, Ann Marie
2010-01-01
To address the translational research question regarding the optimal intervention "dose" to produce the most cost-effective rate of weight loss, we conducted the Drop It At Last (DIAL) study. DIAL is a 6-month pilot randomized trial to examine the efficacy of phone-based weight loss programs with varying levels of treatment contact (10 vs. 20 sessions) in comparison to self-directed treatment. Participants were recruited from the community via mailings and advertisement. Participants were 63 adults with a body mass index between 30 and 39 kg/m(2). Participants received a standard set of print materials and were randomized to either: (1) self-directed treatment; (2) 10 phone coaching sessions; or (3) 20 phone coaching sessions. Measured height, weight, and psychosocial and weight-related self-monitoring measures were collected at baseline and follow-up. General linear models were used to examine 6-month treatment group differences in weight loss and in psychosocial and behavioral measures. Weight losses were -2.3, -3.2, and -4.9 kg in the self-directed, 10-session, and 20-session groups, respectively (p < .21). Participants who completed 10 or more sessions lost more weight (-5.1 kg) compared to those completed four or fewer sessions (-.3 kg, p < .04). Phone-based weight loss program participation is associated with modest weight loss. The optimal dose and timing of intervention warrant further study.
Effects of bending on the superconducting critical current density of monofilamentary Nb3Sn wires
NASA Astrophysics Data System (ADS)
Kaiho, K.; Luhman, T. S.; Suenaga, M.; Sampson, W. B.
1980-02-01
Variations in the superconducting current density Jc of the Nb3Sn wires upon bending were measured for a series of monofilamentary wires in which the ratio Rv of the matrix (Cu+Sn) to the core (Nb3Sn,Nb) was changed from 0 to 58. In most cases Jc was found to increase slightly until the bending strain exceeded a value of ɛirrB , beyond which it severely and irreversibly degraded. For wires with intermediate values of Rv (˜2 to 10), ɛirrB , calculated by geometrical considerations, was substantially lower than the measured value of the tensile strain ɛirrT which was required to irreversibly degrade the critical current. The influence of bending strains on Jc can qualitatively be described by considering residual prestrains in the matrix and the core.
NASA Astrophysics Data System (ADS)
Yang, MinHo; Kim, Dong Seok; Sim, Jae-Wook; Jeong, Jae-Min; Kim, Do Hyun; Choi, Jae Hyung; Kim, Jinsoo; Kim, Seung-Soo; Choi, Bong Gill
2017-06-01
Three-dimensional (3D) carbon materials derived from waste biomass have been attracted increasing attention in catalysis and materials science because of their great potential of catalyst supports with respect to multi-functionality, unique structures, high surface area, and low cost. Here, we present a facile and efficient way for preparing 3D heterogeneous catalysts based on vertical MnO2 wires deposited on hemp-derived 3D porous carbon. The 3D porous carbon materials are fabricated by carbonization and activation processes using hemp (Cannabis Sttiva L.). These 3D porous carbon materials are employed as catalyst supports for direct deposition of vertical MnO2 wires using a one-step hydrothermal method. The XRD and XPS results reveal the crystalline structure of α-MnO2 wires. The resultant composites are further employed as a catalyst for glycolysis of poly(ethylene terephthalate) (PET) with high conversion yield of 98%, which is expected to be expressly profitable for plastics recycling industry.
An interactive wire-wrap board layout program
NASA Technical Reports Server (NTRS)
Schlutsmeyer, A.
1987-01-01
An interactive computer-graphics-based tool for specifying the placement of electronic parts on a wire-wrap circuit board is presented. Input is a data file (currently produced by a commercial logic design system) which describes the parts used and their interconnections. Output includes printed reports describing the parts and wire paths, parts counts, placement lists, board drawing, and a tape to send to the wire-wrap vendor. The program should reduce the engineer's layout time by a factor of 3 to 5 as compared to manual methods.
Design and development of equipment for laser wire stripping
NASA Technical Reports Server (NTRS)
Iceland, W. F.
1977-01-01
Three laser wire strippers have been built for the stripping of Kapton-insulated wire, the baseline wire of the space shuttle orbiter. The strippers are: (1) a bench-model stripper powered with a cw CO2 10.6-micron laser, (2) a hand-held stripper powered with a cw 1.06-micron Nd-YAG laser with an output of 5-7 watts, and (3) a hand-held stripper with a five-inch-long CO2 laser inside the stripping head.
Heat Transfer Characteristics of Regenerator Matrix (Case of Packed Wire Gauzes)
NASA Technical Reports Server (NTRS)
Hamaguchi, K.; Takahashi, S.; Miyabe, H.
1984-01-01
The average heat transfer coefficient in the matrix of laminated wire screens (10 to 250 mesh) for a Stirling engine heat exchanger was studied experimentally. The data are correlated by N sub ud = 0.42 R sub ed 0.56 (3 or = R sub ed or = 400), and R sub ed are the Nusselt and Reynolds nubmers based on the wire diameter. The pressure drop decreased and the heat transfer increased as the wire diameter was decreased.
High conductivity carbon nanotube wires from radial densification and ionic doping
NASA Astrophysics Data System (ADS)
Alvarenga, Jack; Jarosz, Paul R.; Schauerman, Chris M.; Moses, Brian T.; Landi, Brian J.; Cress, Cory D.; Raffaelle, Ryne P.
2010-11-01
Application of drawing dies to radially densify sheets of carbon nanotubes (CNTs) into bulk wires has shown the ability to control electrical conductivity and wire density. Simultaneous use of KAuBr4 doping solution, during wire drawing, has led to an electrical conductivity in the CNT wire of 1.3×106 S/m. Temperature-dependent electrical measurements show that conduction is dominated by fluctuation-assisted tunneling, and introduction of KAuBr4 significantly reduces the tunneling barrier between individual nanotubes. Ultimately, the concomitant doping and densification process leads to closer packed CNTs and a reduced charge transfer barrier, resulting in enhanced bulk electrical conductivity.
Electrical Arc Ignition Testing of Spacesuit Materials
NASA Technical Reports Server (NTRS)
Smith, Sarah; Gallus, Tim; Tapia, Susana; Ball, Elizabeth; Beeson, Harold
2006-01-01
A viewgraph presentation on electrical arc ignition testing of spacesuit materials is shown. The topics include: 1) Background; 2) Test Objectives; 3) Test Sample Materials; 4) Test Methods; 5) Scratch Test Objectives; 6) Cotton Scratch Test Video; 7) Scratch Test Results; 8) Entire Date Plot; 9) Closeup Data Plot; 10) Scratch Test Problems; 11) Poke Test Objectives; 12) Poke Test Results; 13) Poke Test Problems; 14) Wire-break Test Objectives; 15) Cotton Wire-Break Test Video; 16) High Speed Cotton Wire-break Test Video; 17) Typical Data Plot; 18) Closeup Data Plot; 19) Wire-break Test Results; 20) Wire-break Tests vs. Scratch Tests; 21) Urethane-coated Nylon; and 22) Moleskin.
Redmayne, Mary
2013-01-10
Cellphone and cordless phone use is very prevalent among early adolescents, but the extent and types of use is not well documented. This paper explores how, and to what extent, New Zealand adolescents are typically using and exposed to active cellphones and cordless phones, and considers implications of this in relation to brain tumour risk, with reference to current research findings. This cross-sectional study recruited 373 Year 7 and 8 school students with a mean age of 12.3 years (range 10.3-13.7 years) from the Wellington region of New Zealand. Participants completed a questionnaire and measured their normal body-to-phone texting distances. Main exposure-metrics included self-reported time spent with an active cellphone close to the body, estimated time and number of calls on both phone types, estimated and actual extent of SMS text-messaging, cellphone functions used and people texted. Statistical analyses used Pearson Chi2 tests and Pearson's correlation coefficient (r). Analyses were undertaken using SPSS version 19.0. Both cellphones and cordless phones were used by approximately 90% of students. A third of participants had already used a cordless phone for ≥ 7 years. In 4 years from the survey to mid-2013, the cordless phone use of 6% of participants would equal that of the highest Interphone decile (≥ 1640 hours), at the surveyed rate of use. High cellphone use was related to cellphone location at night, being woken regularly, and being tired at school. More than a third of parents thought cellphones carried a moderate-to-high health risk for their child. While cellphones were very popular for entertainment and social interaction via texting, cordless phones were most popular for calls. If their use continued at the reported rate, many would be at increased risk of specific brain tumours by their mid-teens, based on findings of the Interphone and Hardell-group studies.
2013-01-01
Background Cellphone and cordless phone use is very prevalent among early adolescents, but the extent and types of use is not well documented. This paper explores how, and to what extent, New Zealand adolescents are typically using and exposed to active cellphones and cordless phones, and considers implications of this in relation to brain tumour risk, with reference to current research findings. Methods This cross-sectional study recruited 373 Year 7 and 8 school students with a mean age of 12.3 years (range 10.3-13.7 years) from the Wellington region of New Zealand. Participants completed a questionnaire and measured their normal body-to-phone texting distances. Main exposure-metrics included self-reported time spent with an active cellphone close to the body, estimated time and number of calls on both phone types, estimated and actual extent of SMS text-messaging, cellphone functions used and people texted. Statistical analyses used Pearson Chi2 tests and Pearson’s correlation coefficient (r). Analyses were undertaken using SPSS version 19.0. Results Both cellphones and cordless phones were used by approximately 90% of students. A third of participants had already used a cordless phone for ≥ 7 years. In 4 years from the survey to mid-2013, the cordless phone use of 6% of participants would equal that of the highest Interphone decile (≥ 1640 hours), at the surveyed rate of use. High cellphone use was related to cellphone location at night, being woken regularly, and being tired at school. More than a third of parents thought cellphones carried a moderate-to-high health risk for their child. Conclusions While cellphones were very popular for entertainment and social interaction via texting, cordless phones were most popular for calls. If their use continued at the reported rate, many would be at increased risk of specific brain tumours by their mid-teens, based on findings of the Interphone and Hardell-group studies. PMID:23302218
NASA Astrophysics Data System (ADS)
Badica, P.; Awaji, S.; Oguro, H.; Nishijima, G.; Watanabe, K.
2006-04-01
Six Nb3Sn composite wires with different architectures ('central and near-the-edge reinforcement') were repeatedly in-plane bent at room temperature (in-plane 'pre-bending'). Breakage behaviour was revealed from scanning electron microscopy observations by semi-quantitative analysis of the filament crack formation and evolution. Cracks are formed in the transversal and longitudinal directions. Transversal cracks show some tolerance to the applied bending strain due to the fact that filaments are composite materials; residual Nb core can arrest development of a partial transversal crack initiated in the Nb3Sn outer part of the filament. Together with the density of cracks C and the evolution of this parameter with pre-bending strain, ɛpb, in different regions of the wire, R-ɛpb curves are important to understand breakage behaviour of the wires. R is the ratio (number of full transversal cracks)/(number of full transversal cracks + number of partial transversal cracks). Parameters C and R allow us to reveal and satisfactorily understand the wire architecture—breakage—critical current decay relationship when pre-bending treatment is applied. As a consequence, breakage criteria necessary to minimize Ic decay were defined and the positive influence of the reinforcement in preventing breakage was observed. It was also found that, in this regard, more Nb in the CuNb reinforcement, for the investigated wires, is better, if the heat treatment for the wire synthesis is performed at 670 °C for 96 h. A different heat treatment, 650 °C for 240 h, is less efficient in preventing filament breakage. Our results suggest the possibility of control and improvement of the breakage susceptibility of the filaments in the wires and, hence, of the bending Ic decay, through the wise design of the wire architecture (i.e. by correlating design with the choice of composing materials and heat treatments).
Temperature-modulated DSC provides new insight about nickel-titanium wire transformations.
Brantley, William A; Iijima, Masahiro; Grentzer, Thomas H
2003-10-01
Differential scanning calorimetry (DSC) is a well-known method for investigating phase transformations in nickel-titanium orthodontic wires; the microstructural phases and phase transformations in these wires have central importance for their clinical performance. The purpose of this study was to use the more recently developed technique of temperature-modulated DSC (TMDSC) to gain insight into transformations in 3 nickel-titanium orthodontic wires: Neo Sentalloy (GAC International, Islandia, NY), 35 degrees C Copper Ni-Ti (Ormco, Glendora, Calif) and Nitinol SE (3M Unitek, Monrovia, Calif). In the oral environment, the first 2 superelastic wires have shape memory, and the third wire has superelastic behavior but not shape memory. All wires had cross-section dimensions of 0.016 x 0.022 in. Archwires in the as-received condition and after bending 135 degrees were cut into 5 or 6 segments for test specimens. TMDSC analyses (Model 2910 DSC, TA Instruments, Wilmington, Del) were conducted between -125 degrees C and 100 degrees C, using a linear heating and cooling rate of 2 degrees C per min, an oscillation amplitude of 0.318 degrees C with a period of 60 seconds, and helium as the purge gas. For all 3 wire alloys, strong low-temperature martensitic transformations, resolved on the nonreversing heat-flow curves, were not present on the reversing heat-flow curves, and bending appeared to increase the enthalpy change for these peaks in some cases. For Neo Sentalloy, TMDSC showed that transformation between martensitic and austenitic nickel-titanium, suggested as occurring directly in the forward and reverse directions by conventional DSC, was instead a 2-step process involving the R-phase. Two-step transformations in the forward and reverse directions were also found for 35 degrees C Copper Ni-Ti and Nitinol SE. The TMDSC results show that structural transformations in these wires are complex. Some possible clinical implications of these observations are discussed.
Hanauer, Matthieu; Perentes, Jean Yannis; Krueger, Thorsten; Ris, Hans-Beat; Bize, Pierre; Schmidt, Sabine; Gonzalez, Michel
2016-01-16
Video-assisted thoracic surgery (VATS) is currently performed to diagnose and treat solitary pulmonary nodules (SPN). However, the intra-operative identification of deep nodules can be challenging with VATS as the lung is difficult to palpate. The aim of the study was to report the utility and the results of pre-operative computed tomography (CT)-guided hook wire localization of SPN. All records of the patients undergoing CT-guided hook wire localization prior to VATS resection for SPN between 2002 and 2013 were reviewed. The efficacy in localizing the nodule, hook wire complications, necessity to convert VATS to thoracotomy and the histology of SPN are reported. One hundred eighty-one patients (90 females, mean age 63 y, range 28-82 y) underwent 187 pulmonary resections after CT-guided hook wire localization. The mean SPN diameter was 10.3 mm (range: 4-29 mm). The mean distance of the lesion from the pleural surface was 11.6 mm (range: 0-45 mm). The mean time interval from hook wire insertion to VATS resection was 224 min (range 54-622 min). Hook wire complications included pneumothorax requiring chest tube drainage in 4 patients (2.1%) and mild parenchymal haemorrhage in 11 (5.9%) patients. Migration of the hook wire occurred in 7 patients (3.7%) although it did not affect the success of VATS resection (nodule location guided by the lung puncture site). Three patients underwent additional wedge resection by VATS during the same procedure because no lesion was identified in the surgical specimen. Conversion thoracotomy was required in 13 patients (7 %) for centrally localized lesions (6 patients) and pleural adhesions (7 patients). The mean operative time was 60 min (range 18-135 min). Pathological examination revealed a malignant lesion in 107 patients (59 %). The diagnostic yield was 98.3 %. VATS resection for SPN after CT-guided hook wire localization for SPN is safe and allows for proper diagnosis with a low thoracotomy conversion rate.
Bakota, Bore; Chan, Gareth; Staresinic, Mario; Rajput, Vishal; Phadnis, Joideep; Korac, Zelimir
2017-11-01
The aim of this study was to present a modified Murray and Schwarz 2.5-mm Kirschner wire (K-wire) intramedullary (IM) technique for fixation of displaced midshaft clavicle fractures (DMCF), and to compare the differences in treatment outcome of two-part (Robinson 2B.1) and multifragmentary (Robinson 2B.2) DMCF. A retrospective analysis of 91 patients who underwent IM fixation with a 2.5-mm K-wire for DMCF and had a 1-year post-operative follow-up between 2000 and 2012 was performed. The patients were allocated into two groups: Robinson 2B.1 (n = 64) and Robinson 2B.2 (n = 27). Assessed outcomes were non-union, reoperation rate, wire migration and infection. There was no statistically significant difference in the rate of non-union (2B.1,2B.2; 3.13%, 7.41%; p = 0.365), reoperation (2B.1, 2B.2; 3.13%, 7.41%; p = 0.365), K-wire migration (2B.1, 2B.2; 0.00%, 0.00%; p = 1.00) and clavicle shortening at 12-months (2B.1, 2B.2; 3.13%, 7.41%; p = 0.365). Intramedullary clavicle fixation with a 2.5-mm K-wire is a safe surgical technique. 2B.1 injuries treated with 2.5-mm IM K-wire fixation have relatively improved outcome compared with displaced 2B.2 fractures for both non-union and reoperation rates. There were no occurrences of implant migration with either 2B.1 or 2B.2 injuries, and a non-significant difference in implant irritation was documented with IM K-fixation. The non-union rate with K-wire IM fixation of 2B.1 injuries concords with the published results of other IM devices and thus this technique should be added to the surgeon's armamentarium when considering surgical treatment of such injuries. © 2017 Elsevier Ltd. All rights reserved.
Höchsmann, C; Knaier, R; Eymann, J; Hintermann, J; Infanger, D; Schmidt-Trucksäss, A
2018-02-20
To examine the validity of popular smartphone accelerometer applications and a consumer activity wristband compared to a widely used research accelerometer while assessing the impact of the phone's position on the accuracy of step detection. Twenty volunteers from 2 different age groups (Group A: 18-25 years, n = 10; Group B 45-70 years, n = 10) were equipped with 3 iPhone SE smartphones (placed in pants pocket, shoulder bag, and backpack), 1 Samsung Galaxy S6 Edge (pants pocket), 1 Garmin Vivofit 2 wristband, and 2 ActiGraph wGTX+ devices (worn at wrist and hip) while walking on a treadmill (1.6, 3.2, 4.8, and 6.0 km/h) and completing a walking course. All smartphones included 6 accelerometer applications. Video observation was used as gold standard. Validity was evaluated by comparing each device with the gold standard using mean absolute percentage errors (MAPE). The MAPE of the iPhone SE (all positions) and the Garmin Vivofit was small (<3) for treadmill walking ≥3.2 km/h and for free walking. The Samsung Galaxy and hip-worn ActiGraph showed small MAPE only for treadmill walking at 4.8 and 6.0 km/h and for free walking. The wrist-worn ActiGraph showed high MAPE (17-47) for all walking conditions. The iPhone SE and the Garmin Vivofit 2 are accurate tools for step counting in different age groups and during various walking conditions, even during slow walking. The phone's position does not impact the accuracy of step detection, which substantially improves the versatility for physical activity assessment in clinical and research settings. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Bracken, M B; Belanger, K; Hellenbrand, K; Addesso, K; Patel, S; Triche, E; Leaderer, B P
1998-09-01
The home wiring code is the most widely used metric for studies of residential electromagnetic field (EMF) exposure and health effects. Despite the fact that wiring code often shows stronger correlations with disease outcome than more direct EMF home assessments, little is known about potential confounders of the wiring code association. In a study carried out in southern Connecticut in 1988-1991, the authors used strict and widely used criteria to assess the wiring codes of 3,259 homes in which respondents lived. They also collected other home characteristics from the tax assessor's office, estimated traffic density around the home from state data, and interviewed each subject (2,967 mothers of reproductive age) for personal characteristics. Women who lived in very high current configuration wiring coded homes were more likely to be in manual jobs and their homes were older (built before 1949, odds ratio (OR) = 73.24, 95% confidence interval (CI) 29.53-181.65) and had lower assessed value and higher traffic densities (highest density quartile, OR = 3.99, 95% CI 1.17-13.62). Because some of these variables have themselves been associated with health outcomes, the possibility of confounding of the wiring code associations must be rigorously evaluated in future EMF research.
Shi, Minjie; Yang, Cheng; Song, Xuefeng; Liu, Jing; Zhao, Liping; Zhang, Peng; Gao, Lian
2017-05-24
Wire-shaped supercapacitors (SCs) based on shape memory materials are of considerable interest for next-generation portable and wearable electronics. However, the bottleneck in this field is how to develop the devices with excellent electrochemical performance while well-maintaining recoverability and flexibility. Herein, a unique asymmetric electrode concept is put forward to fabricate smart wire-shaped SCs with ultrahigh energy density, which is realized by using porous carbon dodecahedra coated on NiTi alloy wire and flexible graphene fiber as yarn electrodes. Notably, the wire-shaped SCs not only exhibit high flexibility that can be readily woven into real clothing but also represent the available recoverable ability. When irreversible plastic deformations happen, the deformed shape of the devices can automatically resume the initial predesigned shape in a warm environment (about 35 °C). More importantly, the wire-shaped SCs act as efficient energy storage devices, which display high volumetric energy density (8.9 mWh/cm 3 ), volumetric power density (1080 mW/cm 3 ), strong durability in multiple mechanical states, and steady electrochemical behavior after repeated shape recovery processes. Considering their relative facile fabrication technology and excellent electrochemical performance, this asymmetric electrode strategy produced smart wire-shaped supercapacitors desirable for multifunctional portable and wearable electronics.
Mobile phone collection, reuse and recycling in the UK
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ongondo, F.O.; Williams, I.D., E-mail: idw@soton.ac.uk
Highlights: > We characterized the key features of the voluntary UK mobile phone takeback network via a survey. > We identified 3 flows: information; product (handsets and accessories); and incentives. > There has been a significant rise in the number of UK takeback schemes since 1997. > Most returned handsets are low quality; little data exists on quantities of mobile phones collected. > Takeback schemes increasingly divert EoL mobile phones from landfill and enable reuse/recycling. - Abstract: Mobile phones are the most ubiquitous electronic product on the globe. They have relatively short lifecycles and because of their (perceived) in-built obsolescence,more » discarded mobile phones represent a significant and growing problem with respect to waste electrical and electronic equipment (WEEE). An emerging and increasingly important issue for industry is the shortage of key metals, especially the types of metals found in mobile phones, and hence the primary aim of this timely study was to assess and evaluate the voluntary mobile phone takeback network in the UK. The study has characterised the information, product and incentives flows in the voluntary UK mobile phone takeback network and reviewed the merits and demerits of the incentives offered. A survey of the activities of the voluntary mobile phone takeback schemes was undertaken in 2008 to: identify and evaluate the takeback schemes operating in the UK; determine the target groups from whom handsets are collected; and assess the collection, promotion and advertising methods used by the schemes. In addition, the survey sought to identify and critically evaluate the incentives offered by the takeback schemes, evaluate their ease and convenience of use; and determine the types, qualities and quantities of mobile phones they collect. The study has established that the UK voluntary mobile phone takeback network can be characterised as three distinctive flows: information flow; product flow (handsets and related accessories); and incentives flow. Over 100 voluntary schemes offering online takeback of mobile phone handsets were identified. The schemes are operated by manufacturers, retailers, mobile phone network service operators, charities and by mobile phone reuse, recycling and refurbishing companies. The latter two scheme categories offer the highest level of convenience and ease of use to their customers. Approximately 83% of the schemes are either for-profit/commercial-oriented and/or operate to raise funds for charities. The voluntary schemes use various methods to collect mobile phones from consumers, including postal services, courier and in-store. The majority of schemes utilise and finance pre-paid postage to collect handsets. Incentives offered by the takeback schemes include monetary payments, donation to charity and entry into prize draws. Consumers from whom handsets and related equipment are collected include individuals, businesses, schools, colleges, universities, charities and clubs with some schemes specialising on collecting handsets from one target group. The majority (84.3%) of voluntary schemes did not provide information on their websites about the quantities of mobile phones they collect. The operations of UK takeback schemes are decentralised in nature. Comparisons are made between the UK's decentralised collection system versus Australia's centralised network for collection of mobile phones. The significant principal conclusions from the study are: there has been a significant rise in the number of takeback schemes operating in the UK since the initial scheme was launched in 1997; the majority of returned handsets seem to be of low quality; and there is very little available information on the quantities of mobile phones collected by the various schemes. Irrespective of their financial motives, UK takeback schemes increasingly play an important role in sustainable waste management by diverting EoL mobile phones from landfills and encouraging reuse and recycling. Recommendations for future actions to improve the management of end-of-life mobile phone handsets and related accessories are made.« less
Hobbelink, Marieke G; He, Yan; Xu, Jia; Xie, Huixu; Stoll, Richard; Ye, Qingsong
2015-01-01
The aim of this study was to investigate the corrosive behaviour of stainless steel archwires in a more clinically relevant way by bending and exposing to various pH. One hundred and twenty pieces of rectangular stainless steel wires (0.43 × 0.64 mm) were randomly assigned into four groups. In each group, there were 15 pieces of bent wires and 15 straight ones. Prior to measurements of the wires, as individual experimental groups (group 1, 2, and 3), the wires were exposed to artificial saliva for 4 weeks at pH 5.6, 6.6, and 7.6, respectively. A control group of wires (group 4) remained in air for the same period of time before sent for measurements. Surface roughness (Ra-value) was measured by a profilometer. Young's modulus and maximum force were determined by a four-point flexural test apparatus. Scanning electron microscopy was used to observe the surface morphology of straight wire. Differences between groups were examined using a two-way analysis of variance (ANOVA). Mean surface roughness values, flexural Young's moduli, and maximum force values of bent wires are significantly different from those of the straight wires, which was the main effect of wire bending, ignoring the influence of pH. A significant effect was found between Ra-values regarding the main effect of pH, ignoring the influence of shape. There was a significant interaction effect of bending and pH on flexural Young's moduli of stainless steel archwires, while pH did not show much impact on the maximum force values of those stainless steel wires. Bigger surface irregularities were seen on SEM images of straight wires immersed in artificial saliva at pH 5.6 compared to artificial saliva at other pH values. Surface depth (Rz) was more sensitive than Ra in revealing surface roughness, both measured from 3D reconstructed SEM images. Ra showed a comparable result of surface roughness to Ra-value measured by the profilometer. Bending has a significant influence on surface roughness and mechanical properties of rectangular SS archwires. pH plays a synergistic effect on the change of mechanical properties of stainless steel (SS) wires along with wire bending.
Lee, Sang Ki; Hwang, Yoon Sub; Choy, Won Sik
2014-03-01
Conventional operative treatments of patella fractures are frequently associated with implant failure or displacement. Recent biomechanical studies showed that the orientation of the wire loop and the site of the wire twist can affect the fixation strength. The purpose of this study was to compare the clinical outcome of the tension band technique with loops in different orientations and different knot positions. For this retrospective study, 72 patella fractures (71 patients) were fixed with figure-of-eight configurations in combination with 2 K-wires. Patients were divided into 3 groups according to the orientation of tension band construct. A total of 40 patella fractures were placed with figure-of-eight configurations in a vertical orientation either with 1 wire twist (group 1; 16 patella fractures) or with 2 wire twists at the adjacent corners (group 2; 24 patella fractures). Thirty-two patella fractures were placed with figure-of-eight configurations in a horizontal orientation with 2 wire twists at the adjacent corners (group 3). Range of motion, complication rates, and knee scoring scales (Hospital for Special Surgery and Lysholm) were assessed during serial follow-up. Satisfactory reductions were achieved in all groups, but functional results in the early stage were different. Group 3 had better Hospital for Special Surgery and Lysholm scores at 3 months postoperatively; however, at 6 months and 1 year postoperatively, all groups had similar scores. At the 1-year follow-up, all groups achieved acceptable flexion and range of motion. The overall complication rate was lower in the horizontal group (12.5%). Placing the figure-of-eight tension band construct in a horizontal orientation can provide functional benefits in the early stage after patella fractures. Copyright 2014, SLACK Incorporated.
NASA Astrophysics Data System (ADS)
Razali, M. F.; Mahmud, A. S.; Mokhtar, N.; Abdullah, J.
2017-10-01
This study investigated the influence of sliding friction toward the effective force of superelastic NiTi arch wire applied in orthodontic bracing for tooth leveling. A three-dimensional finite-element model integrated with superelastic subroutine and contact interaction was used to predict the contribution of friction on force-deflection curve of NiTi wire in three brackets bending configuration. It was found that the friction between the wire and the bracket increased proportionally as a function of wire deflection, thus transforming the constant force characteristic of NiTi material into a slope. The highest magnitude of sliding friction was measured to be 3.1 N and 2.2 N with respect to the activation and deactivation of the arch wire.
Mobile Phone Use in Two Secondary Schools in Tanzania
ERIC Educational Resources Information Center
Joyce-Gibbons, Andrew; Galloway, David; Mollel, Andrew; Mgoma, Sylvester; Pima, Madeleke; Deogratias, Enos
2018-01-01
Mobile phone technology in Tanzania has grown rapidly but there is insufficient data on its application in schools. This paper aims to show how students in the first and third year (F1 and F3) teachers in two rural secondary schools perceived its use. F1 and F3 students completed a questionnaire. Teachers and students in F1 and F3 discussed the…
Effect of dental arch convexity and type of archwire on frictional forces.
Fourie, Zacharias; Ozcan, Mutlu; Sandham, Andrew
2009-07-01
Friction measurements in orthodontics are often derived from models by using brackets placed on flat models with various straight wires. Dental arches are convex in some areas. The objectives of this study were to compare the frictional forces generated in conventional flat and convex dental arch setups, and to evaluate the effect of different archwires on friction in both dental arch models. Two stainless steel models were designed and manufactured simulating flat and convex maxillary right buccal dental arches. Five stainless steel brackets from the maxillary incisor to the second premolar (slot size, 0.22 in, Victory, 3M Unitek, Monrovia, Calif) and a first molar tube were aligned and clamped on the metal model at equal distances of 6 mm. Four kinds of orthodontic wires were tested: (1) A. J. Wilcock Australian wire (0.016 in, G&H Wire, Hannover, Germany); and (2) 0.016 x 0.022 in, (3) 0.018 x 0.022 in, and (4) 0.019 x 0.025 in (3M Unitek GmbH, Seefeld, Germany). Gray elastomeric modules (Power O 110, Ormco, Glendora, Calif) were used for ligation. Friction tests were performed in the wet state with artificial saliva lubrication and by pulling 5 mm of the whole length of the archwire. Six measurements were made from each bracket-wire combination, and each test was performed with new combinations of materials for both arch setups (n = 48, 6 per group) in a universal testing machine (crosshead speed: 20 mm/min). Significant effects of arch model (P = 0.0000) and wire types (P = 0.0000) were found. The interaction term between the tested factors was not significant (P = 0.1581) (2-way ANOVA and Tukey test). Convex models resulted in significantly higher frictional forces (1015-1653 g) than flat models (680-1270 g) (P <0.05). In the flat model, significantly lower frictional forces were obtained with wire types 1 (679 g) and 3 (1010 g) than with types 2 (1146 g) and 4 (1270 g) (P <0.05). In the convex model, the lowest friction was obtained with wire types 1 (1015 g) and 3 (1142 g) (P >0.05). Type 1 wire tended to create the least overall friction in both flat and convex dental arch simulation models.
The hibernating mobile phone: Dead storage as a barrier to efficient electronic waste recovery.
Wilson, Garrath T; Smalley, Grace; Suckling, James R; Lilley, Debra; Lee, Jacquetta; Mawle, Richard
2017-02-01
Hibernation, the dead storage period when a mobile phone is still retained by the user at its end-of-life, is both a common and a significant barrier to the effective flow of time-sensitive stock value within a circular economic model. In this paper we present the findings of a survey of 181 mobile phone owners, aged between 18-25years old, living and studying in the UK, which explored mobile phone ownership, reasons for hibernation, and replacement motives. This paper also outlines and implements a novel mechanism for quantifying the mean hibernation period based on the survey findings. The results show that only 33.70% of previously owned mobile phones were returned back into the system. The average duration of ownership of mobile phones kept and still in hibernation was 4years 11months, with average use and hibernation durations of 1year 11months, and 3years respectively; on average, mobile phones that are kept by the user are hibernated for longer than they are ever actually used as primary devices. The results also indicate that mobile phone replacement is driven primarily by physical (technological, functional and absolute) obsolescence, with economic obsolescence, partly in response to the notion of being 'due an upgrade', also featuring significantly. We also identify in this paper the concept of a secondary phone, a recently replaced phone that holds a different function for the user than their primary phone but is still valued and intentionally retained by the user, and which, we conclude, should be accounted for in any reverse logistics strategy. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Cho, Jae-Hyoung; Lee, Hye-Chung; Lim, Dong-Jun; Kwon, Hyuk-Sang; Yoon, Kun-Ho
2009-01-01
A mobile phone with a glucometer integrated into the battery pack (the 'Diabetes Phone') was launched in Korea in 2003. We compared its effect on management of type 2 diabetes to the Internet-based glucose monitoring system (IBGMS), which had been studied previously. We conducted a randomized trial involving 69 patients for three months. Participants were assigned to an Internet group or a phone group. The phone group communicated with medical staff through the mobile phone only. Their glucose-monitoring data were automatically transferred to individual, web-based charts and they received medical recommendations by short message service. The Internet group used the IBGMS. There were no significant differences between the groups at baseline. After three months' intervention, HbA(1c) levels of both groups had decreased significantly, from 7.6% to 6.9% for the Internet group and from 8.3% to 7.1% for the phone group (P < 0.01). Levels of patient satisfaction and adherence to medical advice were similar. Mobile, bidirectional communication between doctors and patients using the diabetes phone was as effective for glucose control as the previously-studied Internet-based monitoring system and it was good for patient satisfaction and adherence.
Barriers and facilitators to mobile phone use for people with aphasia.
Greig, Carole-Ann; Harper, Renée; Hirst, Tanya; Howe, Tami; Davidson, Bronwyn
2008-01-01
Mobile phone use increases social participation. People with the communication disorder of aphasia are disadvantaged in the use of information and communication technology such as mobile phones and are reported to be more socially isolated than their peers. The World Health Organization's International Classification of Functioning, Disability and Health provides a framework to address the impact of environmental factors on individual participation. The aim of this preliminary study was to identify the barriers and facilitators to mobile phone use for people with aphasia. A qualitative descriptive study involving two phases was conducted: (1) semi-structured interviews with 6 individuals with aphasia who owned or expressed a desire to own a mobile phone; (2) structured observations of key scenarios identified in the interviews of 3 participants who were sampled from the interview study. Results identified 18 barriers and 9 facilitators to mobile phone use. Key barriers and facilitators were identified in the areas of design and features, written support and training, and communicative partners. Mobile phone use can be problematic for people with aphasia. Intervention needs to address the barriers and utilise the facilitators to mobile phone use for this population. Further research is required to inform policy and intervention programs to ensure that people with aphasia have access to this technology.
Palmer, Melissa L; Peitzman, Elizabeth R; Maniak, Peter J; Sieck, Gary C; Prakash, Y S; O'Grady, Scott M
2011-07-15
Human mammary epithelial (HME) cells express several P2Y receptor subtypes located in both apical and basolateral membranes. Apical UTP or ATP-γ-S stimulation of monolayers mounted in Ussing chambers evoked a rapid, but transient decrease in short circuit current (I(sc)), consistent with activation of an apical K+ conductance. In contrast, basolateral P2Y receptor stimulation activated basolateral K+ channels and increased transepithelial Na+ absorption. Chelating intracellular Ca2+ using the membrane-permeable compound BAPTA-AM, abolished the effects of purinoceptor activation on I(sc). Apical pretreatment with charybdotoxin also blocked the I(sc) decrease by >90% and similar magnitudes of inhibition were observed with clotrimazole and TRAM-34. In contrast, iberiotoxin and apamin did not block the effects of apical P2Y receptor stimulation. Silencing the expression of K(Ca)3.1 produced ∼70% inhibition of mRNA expression and a similar reduction in the effects of apical purinoceptor agonists on I(sc). In addition, silencing P2Y2 receptors reduced the level of P2Y2 mRNA by 75% and blocked the effects of ATP-γ-S by 65%. These results suggest that P2Y2 receptors mediate the effects of purinoceptor agonists on K+ secretion by regulating the activity of K(Ca)3.1 channels expressed in the apical membrane of HME cells. The results also indicate that release of ATP or UTP across the apical or basolateral membrane elicits qualitatively different effects on ion transport that may ultimately determine the [Na+]/[K+] composition of fluid within the mammary ductal network.
Cell phones, clothing, and sex: first impressions of power using older African Americans as stimuli.
Ross, Allison; Barker, Kathleen
2003-12-01
Sex, material possessions, and race have long been associated with prestige or status in American society, yet little research has examined this idea. Little is known about the effect of cell phones on first impressions. In a 2 (cell phone: present, absent) x 2 (clothing: jacket, no jacket) x 2 (sex) between-subjects design, 160 women from a predominantly Black college rated stimuli of older, African Americans on 15 items measuring perceived power on three power subscales: expert, legitimate, and coercive. Multivariate analysis of variance showed a 3-way interaction for clothing, cell phone, and sex of stimulus person.
Narayanan, Sareesh Naduvil; Kumar, Raju Suresh; Potu, Bhagath Kumar; Nayak, Satheesha; Bhat, P Gopalakrishna; Mailankot, Maneesh
2010-05-01
The interaction of mobile phone radio-frequency electromagnetic radiation (RF-EMR) with the brain is a serious concern of our society. We evaluated the effect of RF-EMR from mobile phones on passive avoidance behaviour and hippocampal morphology in rats. Healthy male albino Wistar rats were exposed to RF-EMR by giving 50 missed calls (within 1 hour) per day for 4 weeks, keeping a GSM (0.9 GHz/1.8 GHz) mobile phone in vibratory mode (no ring tone) in the cage. After the experimental period, passive avoidance behaviour and hippocampal morphology were studied. Passive avoidance behaviour was significantly affected in mobile phone RF-EMR-exposed rats demonstrated as shorter entrance latency to the dark compartment when compared to the control rats. Marked morphological changes were also observed in the CA(3) region of the hippocampus of the mobile phone-exposed rats in comparison to the control rats. Mobile phone RF-EMR exposure significantly altered the passive avoidance behaviour and hippocampal morphology in rats.
I 5683 you: dialing phone numbers on cell phones activates key-concordant concepts.
Topolinski, Sascha
2011-03-01
When people perform actions, effects associated with the actions are activated mentally, even if those effects are not apparent. This study tested whether sequences of simulations of virtual action effects can be integrated into a meaning of their own. Cell phones were used to test this hypothesis because pressing a key on a phone is habitually associated with both digits (dialing numbers) and letters (typing text messages). In Experiment 1, dialing digit sequences induced the meaning of words that share the same key sequence (e.g., 5683, LOVE). This occurred even though the letters were not labeled on the keypad, and participants were not aware of the digit-letter correspondences. In Experiment 2, subjects preferred dialing numbers implying positive words (e.g., 37326, DREAM) over dialing numbers implying negative words (e.g., 75463, SLIME). In Experiment 3, subjects preferred companies with phone numbers implying a company-related word (e.g., LOVE for a dating agency, CORPSE for a mortician) compared with companies with phone numbers implying a company-unrelated word.
48 CFR 750.7110-3 - Submission of cases to the M/OP Director.
Code of Federal Regulations, 2010 CFR
2010-10-01
... address; (5) Name, address, and phone number of contractor's representative; (6) Name, office symbol, and phone number of cognizant contracting officer; (7) Amount of request. [62 FR 40469, July 29, 1997, as...