Sample records for uv detector set

  1. Evaluation of State-of-the-Art High Speed Deluge Systems Presently in Service at Various U.S. Army Ammunition Plants

    DTIC Science & Technology

    1993-09-01

    designed to respond to. No data exists on spectral irradiances in the IR or UV spectral bands where the current detectors operate. A need exists to...appropriate fire/explosion detection spectral bands. Setting a pyrotechnic fire and testing the responses of commercial UV and IR detectors that are designed...PNZ B. DETECTOR BACKGROUND ............... 30 C. UV DETECTORS . . ............ . . . 32 D. IR DETECTORS . . . ......... . . ... 34 E. MACHINE VISION

  2. Experimental set up for the irradiation of biological samples and nuclear track detectors with UV C

    PubMed Central

    Portu, Agustina Mariana; Rossini, Andrés Eugenio; Gadan, Mario Alberto; Bernaola, Omar Alberto; Thorp, Silvia Inés; Curotto, Paula; Pozzi, Emiliano César Cayetano; Cabrini, Rómulo Luis; Martin, Gisela Saint

    2016-01-01

    Aim In this work we present a methodology to produce an “imprint” of cells cultivated on a polycarbonate detector by exposure of the detector to UV C radiation. Background The distribution and concentration of 10B atoms in tissue samples coming from BNCT (Boron Neutron Capture Therapy) protocols can be determined through the quantification and analysis of the tracks forming its autoradiography image on a nuclear track detector. The location of boron atoms in the cell structure could be known more accurately by the simultaneous observation of the nuclear tracks and the sample image on the detector. Materials and Methods A UV C irradiator was constructed. The irradiance was measured along the lamp direction and at different distances. Melanoma cells were cultured on polycarbonate foils, incubated with borophenylalanine, irradiated with thermal neutrons and exposed to UV C radiation. The samples were chemically attacked with a KOH solution. Results A uniform irradiation field was established to expose the detector foils to UV C light. Cells could be seeded on the polycarbonate surface. Both imprints from cells and nuclear tracks were obtained after chemical etching. Conclusions It is possible to yield cellular imprints in polycarbonate. The nuclear tracks were mostly present inside the cells, indicating a preferential boron uptake. PMID:26933396

  3. Comparison of the response of four aerosol detectors used with ultra high pressure liquid chromatography.

    PubMed

    Hutchinson, Joseph P; Li, Jianfeng; Farrell, William; Groeber, Elizabeth; Szucs, Roman; Dicinoski, Greg; Haddad, Paul R

    2011-03-25

    The responses of four different types of aerosol detectors have been evaluated and compared to establish their potential use as a universal detector in conjunction with ultra high pressure liquid chromatography (UHPLC). Two charged-aerosol detectors, namely Corona CAD and Corona Ultra, and also two different types of light-scattering detectors (an evaporative light scattering detector, and a nano-quantity analyte detector [NQAD]) were evaluated. The responses of these detectors were systematically investigated under changing experimental and instrumental parameters, such as the mobile phase flow-rate, analyte concentration, mobile phase composition, nebulizer temperature, evaporator temperature, evaporator gas flow-rate and instrumental signal filtering after detection. It was found that these parameters exerted non-linear effects on the responses of the aerosol detectors and must therefore be considered when designing analytical separation conditions, particularly when gradient elution is performed. Identical reversed-phase gradient separations were compared on all four aerosol detectors and further compared with UV detection at 200 nm. The aerosol detectors were able to detect all 11 analytes in a test set comprising species having a variety of physicochemical properties, whilst UV detection was applicable only to those analytes containing chromophores. The reproducibility of the detector response for 11 analytes over 10 consecutive separations was found to be approximately 5% for the charged-aerosol detectors and approximately 11% for the light-scattering detectors. The tested analytes included semi-volatile species which exhibited a more variable response on the aerosol detectors. Peak efficiencies were generally better on the aerosol detectors in comparison to UV detection and particularly so for the light-scattering detectors which exhibited efficiencies of around 110,000 plates per metre. Limits of detection were calculated using different mobile phase compositions and the NQAD detector was found to be the most sensitive (LOD of 10 ng/mL), followed by the Corona CAD (76 ng/mL), then UV detection at 200 nm (178 ng/mL) using an injection volume of 25 μL. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Effects of long-duration exposure on optical system components

    NASA Technical Reports Server (NTRS)

    Harvey, Gale A.

    1991-01-01

    The optical materials and UV detectors experiment (SOO50-1) was a set of 18 optical windows, filters, and ultraviolet detectors. The optical specimens were all retrieved in excellent condition. No delamination or blistering of the filters occurred. No discoloration of the optical window materials occurred, but the MgF2 window did experience roughing. The most notable degradation of the optics were the deposition of an organic film on the exposed surfaces. The film absorption was measured using a Fourier transform infrared spectrometer and a UV spectrometer. The 6 percent absorption at 3.4 microns corresponds to about 100 mgm/sq ft of organic film. The UV absorption was almost 100 percent at 200 nm and about 50 percent at 380 nm.

  5. Characterization of Firing Range Soil from Camp Edwards, MA, and the Efficacy of Acid and Alkaline Hydrolysis for the Remediation of M1 105mm M67 Propellant

    DTIC Science & Technology

    2013-06-01

    method is intended for trace analysis of explosives and propellant residues by high performance liquid chromatography (HPLC) using an ultraviolet (UV...detector set at 254 nm. The HPLC used for this analysis was a Dionex Summit System with a UV detector equipped with Dionex E1 and E2 columns...Ca(OH)2) and sodium hydroxide (NaOH) were evaluated as sources of hydroxide ion for the alkaline hydrolysis of M1 propellant in soil from Camp

  6. Bias Selectable Dual Band AlGaN Ultra-violet Detectors

    NASA Technical Reports Server (NTRS)

    Yan, Feng; Miko, Laddawan; Franz, David; Guan, Bing; Stahle, Carl M.

    2007-01-01

    Bias selectable dual band AlGaN ultra-violet (UV) detectors, which can separate UV-A and UV-B using one detector in the same pixel by bias switching, have been designed, fabricated and characterized. A two-terminal n-p-n photo-transistor-like structure was used. When a forward bias is applied between the top electrode and the bottom electrode, the detectors can successfully detect W-A and reject UV-B. Under reverse bias, they can detect UV-B and reject UV-A. The proof of concept design shows that it is feasible to fabricate high performance dual-band UV detectors based on the current AlGaN material growth and fabrication technologies.

  7. Quality assurance and quality control methodologies used within the Austrian UV monitoring network.

    PubMed

    Mario, Blumthaler

    2004-01-01

    The Austrian UVB monitoring network is operational since 1997. Nine detectors for measuring erythemally weighted solar UV irradiance are distributed over Austria in order to cover the main populated areas as well as different levels of altitude. The detectors are calibrated to indicate the UV-Index, the internationally agreed unit for erythemally weighted solar UV irradiance. Calibration is carried out in the laboratory for determination of spectral sensitivity of each detector, and under the sun for absolute comparison with a well-calibrated, double-monochromator spectroradiometer. For the conversion from detector-weighted units to erythemally weighted units a lookup table is used, which is calculated using a radiative transfer model and which reflects the dependence of the conversion on the solar zenith angle and total ozone content of the atmosphere. The uncertainty of the calibration is about +/-7%, dominated by the uncertainty of the calibration lamp for the spectroradiometer (+/-4%). The long-term stability of this type of detectors has been found to be not satisfactory. Therefore, routinely every year all detectors are completely recalibrated. Variations of the calibration factors up to +/-10% are found. Thus, during routine operation, several measures take place for quality control. The measured data are compared to results of model calculations with a radiative transfer model, where clear sky and an aerosol-free atmosphere are assumed. At each site, the UV data are also compared with data from a co-located pyranometer measuring total solar irradiance. These two radiation quantities are well correlated, especially on clear days and when the ozone content is taken into account. If suspicious measurements are found for one detector in the network, a well-calibrated travelling reference detector of the same type is set up side-by-side, allowing the identification of relative differences of approximately 3%. If necessary, a recalibration is carried out. As the main aim for the Austrian UV monitoring network is the information of the public about the actual levels of UVB irradiance, the measurement results are published on-line in the Internet (http://www.uibk.ac.at/projects/uv-index). For the previous day and backwards approximately 2 years, the distribution of maximal UVB levels over Austria is shown on a regional map. Additionally, near real-time data of most of the measurement stations are presented with a delay of usually less than half-an-hour. Together with these actually measured data there is also shown the diurnal variation of the maximal expected value of the UV-Index under ideal clear conditions.

  8. UV and Optical Detectors: Status and Prospects

    NASA Technical Reports Server (NTRS)

    Woodgate, Bruce; Oegerle, William (Technical Monitor)

    2002-01-01

    UV and visible detectors - status and prospects. The status and prospects for UV and visible detectors for space astrophysics missions will be described, based on the findings of the NASA working group roadmap report, hopefully updated.

  9. Fire Protection System for Hardened Aircraft Shelters. Volume 1. Discussion and Appendixes A-C

    DTIC Science & Technology

    1987-10-01

    in any configuration, for exanple IR, lR-lR, UV -IR, UV , UV -IR- UV . The advantage of multiwavelength detectors is a reduced likelihood of false alarm. B...11late is ,ai led the work function if the metal. Th, operating envelope of a UV detector is . function u (i) the Inc-tal used fir the cathode, and Ŗ...second or two longer. E. DI1AL-CHANNEL UV /IR JETIT .OIRS iiarmy false alar.m sources for UV and IR detectors are mutally exclusive. Th -. has led to the

  10. Enhancing the far-UV sensitivity of silicon CMOS imaging arrays

    NASA Astrophysics Data System (ADS)

    Retherford, K. D.; Bai, Yibin; Ryu, Kevin K.; Gregory, J. A.; Welander, Paul B.; Davis, Michael W.; Greathouse, Thomas K.; Winter, Gregory S.; Suntharalingam, Vyshnavi; Beletic, James W.

    2014-07-01

    We report our progress toward optimizing backside-illuminated silicon PIN CMOS devices developed by Teledyne Imaging Sensors (TIS) for far-UV planetary science applications. This project was motivated by initial measurements at Southwest Research Institute (SwRI) of the far-UV responsivity of backside-illuminated silicon PIN photodiode test structures described in Bai et al., SPIE, 2008, which revealed a promising QE in the 100-200 nm range as reported in Davis et al., SPIE, 2012. Our effort to advance the capabilities of thinned silicon wafers capitalizes on recent innovations in molecular beam epitaxy (MBE) doping processes. Key achievements to date include: 1) Representative silicon test wafers were fabricated by TIS, and set up for MBE processing at MIT Lincoln Laboratory (LL); 2) Preliminary far-UV detector QE simulation runs were completed to aid MBE layer design; 3) Detector fabrication was completed through the pre-MBE step; and 4) Initial testing of the MBE doping process was performed on monitoring wafers, with detailed quality assessments. Early results suggest that potential challenges in optimizing the UV-sensitivity of silicon PIN type CMOS devices, compared with similar UV enhancement methods established for CCDs, have been mitigated through our newly developed methods. We will discuss the potential advantages of our approach and briefly describe future development steps.

  11. Enhancing the far-ultraviolet sensitivity of silicon complementary metal oxide semiconductor imaging arrays

    NASA Astrophysics Data System (ADS)

    Retherford, Kurt D.; Bai, Yibin; Ryu, Kevin K.; Gregory, James A.; Welander, Paul B.; Davis, Michael W.; Greathouse, Thomas K.; Winters, Gregory S.; Suntharalingam, Vyshnavi; Beletic, James W.

    2015-10-01

    We report our progress toward optimizing backside-illuminated silicon P-type intrinsic N-type complementary metal oxide semiconductor devices developed by Teledyne Imaging Sensors (TIS) for far-ultraviolet (UV) planetary science applications. This project was motivated by initial measurements at Southwest Research Institute of the far-UV responsivity of backside-illuminated silicon PIN photodiode test structures, which revealed a promising QE in the 100 to 200 nm range. Our effort to advance the capabilities of thinned silicon wafers capitalizes on recent innovations in molecular beam epitaxy (MBE) doping processes. Key achievements to date include the following: (1) representative silicon test wafers were fabricated by TIS, and set up for MBE processing at MIT Lincoln Laboratory; (2) preliminary far-UV detector QE simulation runs were completed to aid MBE layer design; (3) detector fabrication was completed through the pre-MBE step; and (4) initial testing of the MBE doping process was performed on monitoring wafers, with detailed quality assessments.

  12. Comparison of UV-B measurements performed with a Brewer spectrophotometer and a new UVB-1 broad band detector

    NASA Technical Reports Server (NTRS)

    Bais, Alkiviadis F.; Zerefos, Christos S.; Meleti, Charicleia; Ziomas, Ioannis C.

    1994-01-01

    Measurements of the UV-B erythemal dose, based on solar spectra acquired with a Brewer spectrophotometer at Thessaloniki, Greece, are compared to measurements performed with the recently introduced, by the Yankee Environmental Systems, (Robertson type) broad band solar UV-B detector. The spectral response function of this detector, when applied to the Brewer spectral UV-B measurements, results in remarkably comparable estimates of the erythemal UV-B dose. The two instruments provide similar information on the UV-B dose when they are cross-examined under a variety of meteorological and atmospheric conditions and over the a large range of solar zenith angles and total ozone.

  13. Performance Limits of Non-Line-of-Sight Optical Communications

    DTIC Science & Technology

    2015-05-01

    high efficiency solar blind photo detectors. In this project, we address the main challenges towards optimizing the UV communication system...LEDs), solar blind filters, and high efficiency solar blind photo detectors. In this project, we address the main challenges towards optimizing the UV...solar blind filters, and high efficiency solar blind photo detectors. In this project, we address the main challenges towards optimizing the UV

  14. Radiation sensors based on GaN microwires

    NASA Astrophysics Data System (ADS)

    Verheij, D.; Peres, M.; Cardoso, S.; Alves, L. C.; Alves, E.; Durand, C.; Eymery, J.; Lorenz, K.

    2018-05-01

    GaN microwires were shown to possess promising characteristics as building blocks for radiation resistant particle detectors. They were grown by metal organic vapour phase epitaxy with diameters between 1 and 2 μm and lengths around 20 μm. Devices were fabricated by depositing gold contacts at the extremities of the wires using photolithography. The response of these single wire radiation sensors was then studied under irradiation with 2 MeV protons. Severe degradation of the majority of devices only sets in for fluences above protons cm‑2 revealing good radiation resistance. During proton irradiation, a clear albeit small current gain was observed with a corresponding decay time below 1 s. Photoconductivity measurements upon irradiation with UV light were carried out before and after the proton irradiation. Despite a relatively low gain, attributed to significant dark currents caused by a high dopant concentration, fast response times of a few seconds were achieved comparable to state-of-the-art GaN nanowire photodetectors. Irradiation and subsequent annealing resulted in an overall improvement of the devices regarding their response to UV radiation. The photocurrent gain increased compared to the values that were obtained prior to the irradiation, without compromising the decay times. The results indicate the possibility of using GaN microwires not only as UV detectors, but also as particle detectors.

  15. New Detector Developments for Future UV Space Missions

    NASA Astrophysics Data System (ADS)

    Werner, Klaus; Kappelmann, Norbert

    Ultraviolet (UV) astronomy is facing “dark ages”: After the shutdown of the Hubble Space Tele-scope only the WSO/UV mission will be operable in the UV wavelength region with efficient instruments. Improved optics and detectors are necessary for future successor missions to tackle new scientific goals. This drives our development of microchannel plate (MCP) UV-detectors with high quantum efficiency, high spatial resolution and low-power readout electronics. To enhance the quantum efficiency and the lifetime of the MCP detectors we are developing new cathodes and new anodes for these detectors. To achieve high quantum efficiency, we will use caesium-activated gallium nitride as semitransparent photocathodes with a much higher efficiency than default CsI/CsTe cathodes in this wavelength range. The new anodes will be cross-strip anodes with 64 horizontal and 64 vertical electrodes. This type of anode requires a lower gain and leads to an increased lifetime of the detector, compared to MCP detectors with other anode types. The heart of the new developed front-end-electronic for such type of anode is the so called “BEETLE chip”, which was designed by the MPI für Kernphysik Heidelberg for the LHCb ex-periment at CERN. This chip provides 128 input channels with charge-sensitive preamplifiers and shapers. Our design of the complete front-end readout electronics enables a total power con-sumption of less than 10 W. The MCP detector is intrinsically solar blind, single photon counting and has a very low read-out noise. To qualify this new type of detectors we are presently planning to build a small UV telescope for the usage on the German Technology Experimental Carrier (TET). Furthermore we are involved in the new German initiative for a Public Telescope, a space telescope equipped with an 80 cm mirror. One of the main instruments will be a high-resolution UV-Echelle Spectrograph that will be built by the University of Tübingen. The launch of this mission is scheduled for 2017.

  16. Characterization of the UV detector of Solar Orbiter/Metis

    NASA Astrophysics Data System (ADS)

    Uslenghi, Michela; Schühle, Udo H.; Teriaca, Luca; Heerlein, Klaus; Werner, Stephan

    2017-08-01

    Metis, one of the instruments of the ESA mission Solar Orbiter (to be launched in February 2019), is a coronograph able to perform broadband polarization imaging in the visible range (580-640 nm), and narrow band imaging in UV (HI Lyman-α 121.6 nm) . The detector of the UV channel is an intensified camera, based on a Star-1000 rad-hard CMOS APS coupled via a 2:1 fiber optic taper to a single stage Microchannel Plate intensifier, sealed with an entrance MgF2 window and provided with an opaque KBr photocathode. Before integration in the instrument, the UVDA (UV Detector Assembly) Flight Model has been characterized at the MPS laboratory and calibrated in the UV range using the detector calibration beamline of the Metrology Light Source synchrotron of the Physikalisch-Technische Bundesanstalt (PTB). Linearity, spectral calibration, and response uniformity at 121.6 nm have been measured. Preliminary results are reported in this paper.

  17. A Photoactivated Gas Detector for Toluene Sensing at Room Temperature Based on New Coral-Like ZnO Nanostructure Arrays

    PubMed Central

    Yeh, Li-Ko; Luo, Jie-Chun; Chen, Min-Chun; Wu, Chih-Hung; Chen, Jian-Zhang; Cheng, I-Chun; Hsu, Cheng-Che; Tian, Wei-Cheng

    2016-01-01

    A photoactivated gas detector operated at room temperature was microfabricated using a simple hydrothermal method. We report that the photoactivated gas detector can detect toluene using a UV illumination of 2 μW/cm2. By ultraviolet (UV) illumination, gas detectors sense toluene at room temperature without heating. A significant enhancement of detector sensitivity is achieved because of the high surface-area-to-volume ratio of the morphology of the coral-like ZnO nanorods arrays (NRAs) and the increased number of photo-induced oxygen ions under UV illumination. The corresponding sensitivity (ΔR/R0) of the detector based on coral-like ZnO NRAs is enhanced by approximately 1022% compared to that of thin-film detectors. The proposed detector greatly extends the dynamic range of detection of metal-oxide-based detectors for gas sensing applications. We report the first-ever detection of toluene with a novel coral-like NRAs gas detector at room temperature. A sensing mechanism model is also proposed to explain the sensing responses of gas detectors based on coral-like ZnO NRAs. PMID:27809222

  18. A Photoactivated Gas Detector for Toluene Sensing at Room Temperature Based on New Coral-Like ZnO Nanostructure Arrays.

    PubMed

    Yeh, Li-Ko; Luo, Jie-Chun; Chen, Min-Chun; Wu, Chih-Hung; Chen, Jian-Zhang; Cheng, I-Chun; Hsu, Cheng-Che; Tian, Wei-Cheng

    2016-10-31

    A photoactivated gas detector operated at room temperature was microfabricated using a simple hydrothermal method. We report that the photoactivated gas detector can detect toluene using a UV illumination of 2 μW/cm². By ultraviolet (UV) illumination, gas detectors sense toluene at room temperature without heating. A significant enhancement of detector sensitivity is achieved because of the high surface-area-to-volume ratio of the morphology of the coral-like ZnO nanorods arrays (NRAs) and the increased number of photo-induced oxygen ions under UV illumination. The corresponding sensitivity (ΔR/R₀) of the detector based on coral-like ZnO NRAs is enhanced by approximately 1022% compared to that of thin-film detectors. The proposed detector greatly extends the dynamic range of detection of metal-oxide-based detectors for gas sensing applications. We report the first-ever detection of toluene with a novel coral-like NRAs gas detector at room temperature. A sensing mechanism model is also proposed to explain the sensing responses of gas detectors based on coral-like ZnO NRAs.

  19. Gas amplified ionization detector for gas chromatography

    DOEpatents

    Huston, Gregg C.

    1992-01-01

    A gas-amplified ionization detector for gas chromatrography which possesses increased sensitivity and a very fast response time. Solutes eluding from a gas chromatographic column are ionized by UV photoionization of matter eluting therefrom. The detector is capable of generating easily measured voltage signals by gas amplification/multiplication of electron products resulting from the UV photoionization of at least a portion of each solute passing through the detector.

  20. Deep-UV Emitters and Detectors Based on Lattice-Matched Cubic Oxide Semiconductors (4.2 Optoelectronics)

    DTIC Science & Technology

    2015-05-14

    calculated   by   dividing   photo-­‐‑ generated  current  by  the  optical  power  spectrum  of  the   lamp .    A   UV ...the optimized parameters for growth. Efforts led to significant increases in solar?blind detector responsivity (up to 0.1 A/W) with sub-­ nanoamp...Aug-2014 Approved for Public Release; Distribution Unlimited Final Report: Deep- UV Emitters and Detectors Based on Lattice- Matched Cubic Oxide

  1. UV superconducting nanowire single-photon detectors with high efficiency, low noise, and 4 K operating temperature

    NASA Astrophysics Data System (ADS)

    Wollman, E. E.; Verma, V. B.; Beyer, A. D.; Briggs, R. M.; Korzh, B.; Allmaras, J. P.; Marsili, F.; Lita, A. E.; Mirin, R. P.; Nam, S. W.; Shaw, M. D.

    2017-10-01

    For photon-counting applications at ultraviolet wavelengths, there are currently no detectors that combine high efficiency (> 50%), sub-nanosecond timing resolution, and sub-Hz dark count rates. Superconducting nanowire single-photon detectors (SNSPDs) have seen success over the past decade for photon-counting applications in the near-infrared, but little work has been done to optimize SNSPDs for wavelengths below 400 nm. Here, we describe the design, fabrication, and characterization of UV SNSPDs operating at wavelengths between 250 and 370 nm. The detectors have active areas up to 56 ${\\mu}$m in diameter, 70 - 80% efficiency, timing resolution down to 60 ps FWHM, blindness to visible and infrared photons, and dark count rates of ~ 0.25 counts/hr for a 56 ${\\mu}$m diameter pixel. By using the amorphous superconductor MoSi, these UV SNSPDs are also able to operate at temperatures up to 4.2 K. These performance metrics make UV SNSPDs ideal for applications in trapped-ion quantum information processing, lidar studies of the upper atmosphere, UV fluorescent-lifetime imaging microscopy, and photon-starved UV astronomy.

  2. A charged aerosol detector/chemiluminescent nitrogen detector/liquid chromatography/mass spectrometry system for regular and fragment compound analysis in drug discovery.

    PubMed

    Jiang, Yutao; Hascall, Daniel; Li, Delia; Pease, Joseph H

    2015-09-11

    In this paper, we introduce a high throughput LCMS/UV/CAD/CLND system that improves upon previously reported systems by increasing both the quantitation accuracy and the range of compounds amenable to testing, in particular, low molecular weight "fragment" compounds. This system consists of a charged aerosol detector (CAD) and chemiluminescent nitrogen detector (CLND) added to a LCMS/UV system. Our results show that the addition of CAD and CLND to LCMS/UV is more reliable for concentration determination for a wider range of compounds than either detector alone. Our setup also allows for the parallel analysis of each sample by all four detectors and so does not significantly increase run time per sample. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Development of a Simple RP-HPLC-UV Method for Determination of Azithromycin in Bulk and Pharmaceutical Dosage forms as an Alternative to the USP Method

    PubMed Central

    Ghari, Tayebeh; Kobarfard, Farzad; Mortazavi, Seyed Alireza

    2013-01-01

    The present study was designed to develop a simple, validated liquid chromatographic method for the analysis of azithromycin in bulk and pharmaceutical dosage forms using ultraviolet detector. The best stationary phase was determined as C18 column, 5 μm, 250 mm × 4.6 mm. Mobile phase was optimized to obtain a fast and selective separation of the drug. Flow rate was 1.5 mL/min, Wavelength was set at 210 nm and the volume of each injection was 500 μL. An isocratic methanol/buffer mobile phase at the ratio of 90:10 v/v gave the best separation and resolution. The proposed method was accurate, precise, sensitive, and linear over a wide range of concentration of azithromycin. The developed method has the advantage of using UV detector compared to the USP method in which electrochemical detector has been used. The validated method was successfully applied to the determination of azithromycin in bulk and pharmaceutical dosage forms. PMID:24250672

  4. SWIFT Observations of a Far UV Luminosity Component in SS433

    NASA Technical Reports Server (NTRS)

    Cannizzo, J. K.; Boyd, P. T.; Dolan, J. F.

    2007-01-01

    SS433 is a binary system showing relativistic Doppler shifts in its two sets of emission lines. The origin of its UV continuum is not well established. We observed SS433 to determine the emission mechanism responsible for its far UV spectrum. The source was observed at several different phases of both its 13 d orbital period and 162.5 d precession period using the UVOT and XRT detector systems on Swift. The far UV spectrum down to 1880 Angstrom lies significantly above the spectral flux distribution predicted by extrapolating the reddened blackbody continuum that fits the spectrum above 3500 Angstroms. The intensity of the far UV flux varies over a period of days and the variability is correlated with the variability of the soft X-ray flux from the source. An emission mechanism in addition to those previously detected in the optical and X-ray regions must exist in the far UV spectrum of SS433.

  5. A Low-Cost Liquid-Chromatography System Using a Spectronic 20-Based Detector.

    ERIC Educational Resources Information Center

    Jezorek, John R.; And Others

    1986-01-01

    Describes the design and evaluation of a Spectronic 20-based detector as well as a simple system for postcolumn derivatization useful for metal-ion chromatographic detection. Both detection and derivatization can be performed in the ultra-violet (UV) mode using a low-cost UV-visible spectrophotometer and UV-region derivatization reagents. (JN)

  6. Single Photon Counting UV Solar-Blind Detectors Using Silicon and III-Nitride Materials

    PubMed Central

    Nikzad, Shouleh; Hoenk, Michael; Jewell, April D.; Hennessy, John J.; Carver, Alexander G.; Jones, Todd J.; Goodsall, Timothy M.; Hamden, Erika T.; Suvarna, Puneet; Bulmer, J.; Shahedipour-Sandvik, F.; Charbon, Edoardo; Padmanabhan, Preethi; Hancock, Bruce; Bell, L. Douglas

    2016-01-01

    Ultraviolet (UV) studies in astronomy, cosmology, planetary studies, biological and medical applications often require precision detection of faint objects and in many cases require photon-counting detection. We present an overview of two approaches for achieving photon counting in the UV. The first approach involves UV enhancement of photon-counting silicon detectors, including electron multiplying charge-coupled devices and avalanche photodiodes. The approach used here employs molecular beam epitaxy for delta doping and superlattice doping for surface passivation and high UV quantum efficiency. Additional UV enhancements include antireflection (AR) and solar-blind UV bandpass coatings prepared by atomic layer deposition. Quantum efficiency (QE) measurements show QE > 50% in the 100–300 nm range for detectors with simple AR coatings, and QE ≅ 80% at ~206 nm has been shown when more complex AR coatings are used. The second approach is based on avalanche photodiodes in III-nitride materials with high QE and intrinsic solar blindness. PMID:27338399

  7. Single Photon Counting UV Solar-Blind Detectors Using Silicon and III-Nitride Materials.

    PubMed

    Nikzad, Shouleh; Hoenk, Michael; Jewell, April D; Hennessy, John J; Carver, Alexander G; Jones, Todd J; Goodsall, Timothy M; Hamden, Erika T; Suvarna, Puneet; Bulmer, J; Shahedipour-Sandvik, F; Charbon, Edoardo; Padmanabhan, Preethi; Hancock, Bruce; Bell, L Douglas

    2016-06-21

    Ultraviolet (UV) studies in astronomy, cosmology, planetary studies, biological and medical applications often require precision detection of faint objects and in many cases require photon-counting detection. We present an overview of two approaches for achieving photon counting in the UV. The first approach involves UV enhancement of photon-counting silicon detectors, including electron multiplying charge-coupled devices and avalanche photodiodes. The approach used here employs molecular beam epitaxy for delta doping and superlattice doping for surface passivation and high UV quantum efficiency. Additional UV enhancements include antireflection (AR) and solar-blind UV bandpass coatings prepared by atomic layer deposition. Quantum efficiency (QE) measurements show QE > 50% in the 100-300 nm range for detectors with simple AR coatings, and QE ≅ 80% at ~206 nm has been shown when more complex AR coatings are used. The second approach is based on avalanche photodiodes in III-nitride materials with high QE and intrinsic solar blindness.

  8. Ultraviolet /UV/ sensitive phosphors for silicon imaging detectors

    NASA Technical Reports Server (NTRS)

    Viehmann, W.; Cowens, M. W.; Butner, C. L.

    1981-01-01

    The fluorescence properties of UV sensitive organic phosphors and the radiometric properties of phosphor coated silicon detectors in the VUV, UV, and visible wavelengths are described. With evaporated films of coronene and liumogen, effective quantum efficiencies of up to 20% have been achieved on silicon photodiodes in the vacuum UV. With thin films of methylmethacrylate (acrylic), which are doped with organic laser dyes and deposited from solution, detector quantum efficiencies of the order of 15% for wavelengths of 120-165 nm and of 40% for wavelengths above 190 nm have been obtained. The phosphor coatings also act as antireflection coatings and thereby enhance the response of coated devices throughout the visible and near IR.

  9. High Throughput, High Yield Fabrication of High Quantum Efficiency Back-Illuminated Photon Counting, Far UV, UV, and Visible Detector Arrays

    NASA Technical Reports Server (NTRS)

    Nikzad, Shouleh; Hoenk, M. E.; Carver, A. G.; Jones, T. J.; Greer, F.; Hamden, E.; Goodsall, T.

    2013-01-01

    In this paper we discuss the high throughput end-to-end post fabrication processing of high performance delta-doped and superlattice-doped silicon imagers for UV, visible, and NIR applications. As an example, we present our results on far ultraviolet and ultraviolet quantum efficiency (QE) in a photon counting, detector array. We have improved the QE by nearly an order of magnitude over microchannel plates (MCPs) that are the state-of-the-art UV detectors for many NASA space missions as well as defense applications. These achievements are made possible by precision interface band engineering of Molecular Beam Epitaxy (MBE) and Atomic Layer Deposition (ALD).

  10. Measurements of UV-A radiation and hazard limits from some types of outdoor lamps

    NASA Astrophysics Data System (ADS)

    El-Moghazy, Essam; Abd-Elmageed, Alaa-Eldin; Reda, Sameh

    2015-05-01

    Illumination using artificial light sources is common in these days. Many manufactures are paying for the design of lamps depending on high efficacy and low UV hazards. This research is focusing on the most useable lamps in the Egyptian markets; High Pressure Mercury (HPM), Metal Halide (MH), and High Pressure Sodium (HPS). A set up for relative spectral power distribution based on single monochromator and UVA silicon detector for absolute irradiance measurements are used. The absolute irradiance in (W/m2) in UVA region of the lamps and their accompanied standard uncertainty are evaluated.

  11. Enabling High Performance Instruments for UV Astronomy and Space Exploration with ALD

    NASA Technical Reports Server (NTRS)

    Greer, F.; Hoenk, M. E.; Jones, T. J.; Jacquot, B. C.; Monacos, S.; Nikzad, S.; Hamden, E.; Schiminovich, D.

    2011-01-01

    Benefits of Atomic Layer Deposition (ALD) for UV instruments and application are: (1) Ultrathin, highly conformal, and uniform films over arbitrarily large surface area (2) High quality films (density, roughness, conductivity, etc.) (3) Angstrom level control of stoichiometry, interfaces, and surface properties (3a) Multilayer nanolaminates/nanocomposites (3b) Low temperature surface engineering UV flight applications enabled by ALD. (1) Anti -reflective coatings/Mirrors/Filters/Optics for UV/Vis/NIR Detectors (2) Surface Passivation for III -N detectors

  12. Fast, Large-Area, Wide-Bandgap UV Photodetector for Cherenkov Light Detection

    NASA Technical Reports Server (NTRS)

    Wrbanek, John D.; Wrbanek, Susan Y.

    2013-01-01

    Due to limited resources available for power and space for payloads, miniaturizing and integrating instrumentation is a high priority for addressing the challenges of manned and unmanned deep space missions to high Earth orbit (HEO), near Earth objects (NEOs), Lunar and Martian orbits and surfaces, and outer planetary systems, as well as improvements to high-altitude aircraft safety. New, robust, and compact detectors allow future instrumentation packages more options in satisfying specific mission goals. A solid-state ultraviolet (UV) detector was developed with a theoretical fast response time and large detection area intended for application to Cherenkov detectors. The detector is based on the wide-bandgap semiconductor zinc oxide (ZnO), which in a bridge circuit can detect small, fast pulses of UV light like those required for Cherenkov detectors. The goal is to replace the role of photomultiplier tubes in Cherenkov detectors with these solid-state devices, saving on size, weight, and required power. For improving detection geometry, a spherical detector to measure high atomic number and energy (HZE) ions from any direction has been patented as part of a larger space radiation detector system. The detector will require the development of solid-state UV photodetectors fast enough (2 ns response time or better) to detect the shockwave of Cherenkov light emitted as the ions pass through a quartz, sapphire, or acrylic ball. The detector must be small enough to fit in the detector system structure, but have an active area large enough to capture enough Cherenkov light from the sphere. The detector is fabricated on bulk single-crystal undoped ZnO. Inter - digitated finger electrodes and contact pads are patterned via photolithography, and formed by sputtered metal of silver, platinum, or other high-conductivity metal.

  13. Development and flight testing of UV optimized Photon Counting CCDs

    NASA Astrophysics Data System (ADS)

    Hamden, Erika T.

    2018-06-01

    I will discuss the latest results from the Hamden UV/Vis Detector Lab and our ongoing work using a UV optimized EMCCD in flight. Our lab is currently testing efficiency and performance of delta-doped, anti-reflection coated EMCCDs, in collaboration with JPL. The lab has been set-up to test quantum efficiency, dark current, clock-induced-charge, and read noise. I will describe our improvements to our circuit boards for lower noise, updates from a new, more flexible NUVU controller, and the integration of an EMCCD in the FIREBall-2 UV spectrograph. I will also briefly describe future plans to conduct radiation testing on delta-doped EMCCDs (both warm, unbiased and cold, biased configurations) thus summer and longer term plans for testing newer photon counting CCDs as I move the HUVD Lab to the University of Arizona in the Fall of 2018.

  14. Demonstration of high-responsivity epitaxial β-Ga2O3/GaN metal–heterojunction-metal broadband UV-A/UV-C detector

    NASA Astrophysics Data System (ADS)

    Kalra, Anisha; Vura, Sandeep; Rathkanthiwar, Shashwat; Muralidharan, Rangarajan; Raghavan, Srinivasan; Nath, Digbijoy N.

    2018-06-01

    We demonstrate epitaxial β-Ga2O3/GaN-based vertical metal–heterojunction-metal (MHM) broadband UV-A/UV-C photodetectors with high responsivity (3.7 A/W) at 256 and 365 nm, UV-to-visible rejection >103, and a photo-to-dark current ratio of ∼100. A small (large) conduction (valence) band offset at the heterojunction of pulsed laser deposition (PLD)-grown β-Ga2O3 on metal organic chemical vapor deposition (MOCVD)-grown GaN-on-silicon with epitaxial registry, as confirmed by X-ray diffraction (XRD) azimuthal scanning, is exploited to realize detectors with an asymmetric photoresponse and is explained with one-dimensional (1D) band diagram simulations. The demonstrated novel vertical MHM detectors on silicon are fully scalable and promising for enabling focal plane arrays for broadband ultraviolet sensing.

  15. Probing Jupiter's Radiation Environment with Juno-UVS

    NASA Astrophysics Data System (ADS)

    Kammer, J.; Gladstone, R.; Greathouse, T. K.; Hue, V.; Versteeg, M. H.; Davis, M. W.; Santos-Costa, D.; Becker, H. N.; Bolton, S. J.; Connerney, J. E. P.; Levin, S.

    2017-12-01

    While primarily designed to observe photon emission from the Jovian aurora, Juno's Ultraviolet Spectrograph (Juno-UVS) has also measured background count rates associated with penetrating high-energy radiation. These background counts are distinguishable from photon events, as they are generally spread evenly across the entire array of the Juno-UVS detector, and as the spacecraft spins, they set a baseline count rate higher than the sky background rate. During eight perijove passes, this background radiation signature has varied significantly on both short (spin-modulated) timescales, as well as longer timescales ( minutes to hours). We present comparisons of the Juno-UVS data across each of the eight perijove passes, with a focus on the count rate that can be clearly attributed to radiation effects rather than photon events. Once calibrated to determine the relationship between count rate and penetrating high-energy radiation (e.g., using existing GEANT models), these in situ measurements by Juno-UVS will provide additional constraints to radiation belt models close to the planet.

  16. Monitoring the High-Energy Radiation Environment of Exoplanets Around Low-mass Stars with SPARCS (Star-Planet Activity Research CubeSat)

    NASA Astrophysics Data System (ADS)

    Shkolnik, Evgenya L.; Ardila, David; Barman, Travis; Beasley, Matthew; Bowman, Judd D.; Gorjian, Varoujan; Jacobs, Daniel; Jewell, April; Llama, Joe; Meadows, Victoria; Nikzad, Shouleh; Scowen, Paul; Swain, Mark; Zellem, Robert

    2018-01-01

    Roughly seventy-five billion M dwarfs in our galaxy host at least one small planet in the habitable zone (HZ). The stellar ultraviolet (UV) radiation from M dwarfs is strong and highly variable, and impacts planetary atmospheric loss, composition and habitability. These effects are amplified by the extreme proximity of their HZs (0.1–0.4 AU). Knowing the UV environments of M dwarf planets will be crucial to understanding their atmospheric composition and a key parameter in discriminating between biological and abiotic sources for observed biosignatures. The Star-Planet Activity Research CubeSat (SPARCS) will be a 6U CubeSat devoted to photometric monitoring of M stars in the far-UV and near-UV, measuring the time-dependent spectral slope, intensity and evolution of M dwarf stellar UV radiation. For each target, SPARCS will observe continuously over at least one complete stellar rotation (5 - 45 days). SPARCS will also advance UV detector technology by flying high quantum efficiency, UV-optimized detectors developed at JPL. These Delta-doped detectors have a long history of deployment demonstrating greater than five times the quantum efficiency of the detectors used by GALEX. SPARCS will pave the way for their application in missions like LUVOIR or HabEx, including interim UV-capable missions. SPARCS will also be capable of ‘target-of-opportunity’ UV observations for the rocky planets in M dwarf HZs soon to be discovered by NASA’s TESS mission, providing the needed UV context for the first habitable planets that JWST will characterize.Acknowledgements: Funding for SPARCS is provided by NASA’s Astrophysics Research and Analysis program, NNH16ZDA001N.

  17. Standardization of UV LED measurements

    NASA Astrophysics Data System (ADS)

    Eppeldauer, G. P.; Larason, T. C.; Yoon, H. W.

    2015-09-01

    Traditionally used source spectral-distribution or detector spectral-response based standards cannot be applied for accurate UV LED measurements. Since the CIE standardized rectangular-shape spectral response function for UV measurements cannot be realized with small spectral mismatch when using filtered detectors, the UV measurement errors can be several times ten percent or larger. The UV LEDs produce broadband radiation and both their peaks or spectral bandwidths can change significantly. The detectors used for the measurement of these LEDs also have different spectral bandwidths. In the discussed example, where LEDs with 365 nm peak are applied for fluorescent crack-recognition using liquid penetrant (non-destructive) inspection, the broadband radiometric LED (signal) measurement procedure is standardized. A UV LED irradiance-source was calibrated against an FEL lamp standard to determine its spectral irradiance. The spectral irradiance responsivity of a reference UV meter was also calibrated. The output signal of the reference UV meter was calculated from the spectral irradiance of the UV source and the spectral irradiance responsivity of the reference UV meter. From the output signal, both the integrated irradiance (in the reference plane of the reference meter) and the integrated responsivity of the reference meter were determined. Test UV meters calibrated for integrated responsivity against the reference UV meter, can be used to determine the integrated irradiance from a field UV source. The obtained 5 % (k=2) measurement uncertainty can be decreased when meters with spectral response close to a constant value are selected.

  18. Visible and Ultraviolet Detectors for High Earth Orbit and Lunar Observatories

    NASA Technical Reports Server (NTRS)

    Woodgate, Bruce E.

    1989-01-01

    The current status of detectors for the visible and UV for future large observatories in earth orbit and the moon is briefly reviewed. For the visible, CCDs have the highest quantum efficiency, but are subject to contamination of the data by cosmic ray hits. For the moon, the level of hits can be brought down to that at the earth's surface by shielding below about 20 meters of rock. For high earth orbits above the geomagnetic shield, CCDs might be able to be used by combining many short exposures and vetoing the cosmic ray hits, otherwise photoemissive detectors will be necessary. For the UV, photoemissive detectors will be necessary to reject the visible; to use CCDs would require the development of UV-efficient filters which reject the visible by many orders of magnitude. Development of higher count rate capability would be desirable for photoemissive detectors.

  19. Towards a high performing UV-A sensor based on Silicon Carbide and hydrogenated Silicon Nitride absorbing layers

    NASA Astrophysics Data System (ADS)

    Mazzillo, M.; Sciuto, A.; Mannino, G.; Renna, L.; Costa, N.; Badalà, P.

    2016-10-01

    Exposure to ultraviolet (UV) radiation is a major risk factor for most skin cancers. The sun is our primary natural source of UV radiation. The strength of the sun's ultraviolet radiation is expressed as Solar UV Index (UVI). UV-A (320-400 nm) and UV-B (290-320 nm) rays mostly contribute to UVI. UV-B is typically the most destructive form of UV radiation because it has enough energy to cause photochemical damage to cellular DNA. Also overexposure to UV-A rays, although these are less energetic than UV-B photons, has been associated with toughening of the skin, suppression of the immune system, and cataract formation. The use of preventive measures to decrease sunlight UV radiation absorption is fundamental to reduce acute and irreversible health diseases to skin, eyes and immune system. In this perspective UV sensors able to monitor in a monolithic and compact chip the UV Index and relative UV-A and UV-B components of solar spectrum can play a relevant role for prevention, especially in view of the integration of these detectors in close at hand portable devices. Here we present the preliminary results obtained on our UV-A sensor technology based on the use of hydrogenated Silicon Nitride (SiN:H) thin passivating layers deposited on the surface of thin continuous metal film Ni2Si/4H-SiC Schottky detectors, already used for UV-Index monitoring. The first UV-A detector prototypes exhibit a very low leakage current density of about 0.2 pA/mm2 and a peak responsivity value of 0.027 A/W at 330 nm, both measured at 0V bias.

  20. Impact of environmental factors on PADC radon detector sensitivity during long term storage

    NASA Astrophysics Data System (ADS)

    Wasikiewicz, J. M.

    2018-01-01

    A broad set of data on poly-allyl diglycol carbonate (PADC) exposure to various environmental conditions has been collected for a period of 1 year in order to study the aging effect on the sensitivity to radon detection. Aging is a phenomenon that occurs during long PADC storage resulting in a loss of sensitivity and/or creation of false tracks. Conditions under investigation were storages under pure nitrogen or air atmospheres, in water solutions of different pHs, in a range of temperatures, humidity and exposure to UV, gamma and neutron radiations. It was found that PADC strongly responds to some external conditions through physical changes in the polymer material; for example, etching of UV exposed detectors led to 10% loss of their thickness and the removal of the tracks layer. Performance of detectors was compared with a control that was the sensitivity of detectors from the same sheet at the time of primary calibration - within 1 month of each sheet being manufactured. Substantial difference in performance was found between storage under pure, dry nitrogen and in the presence of water. The former preserves PADC radon detection properties for the period of one year without noticeable change. The latter, on the other hand significantly reduces its performance even after 3 months' storage. It was also established that storage under low temperature is not a suitable means to preserve PADC sensitivity to radon detection due to significant loss in the detector sensitivity.

  1. Tin-gallium-oxide-based UV-C detectors

    NASA Astrophysics Data System (ADS)

    Mukhopadhyay, Partha; Toporkov, Mykyta; Schoenfeld, Winston V.

    2018-02-01

    The emergence of conductive gallium oxide single crystal substrates offers the potential for vertical Schottky detectors operating in the UV-C spectral region. We report here on our recent work in the development of Tin Gallium oxide (TGO) thin film metal-semiconductor-metal (MSM) and Schottky detectors using plasma-assisted molecular beam epitaxy on c plane sapphire and bulk Ga2O3 substrates. Tin alloying of gallium oxide thin films was found to systematically reduce the optical band gap of the compound, providing tunability in the UV-C spectral region. Tin concentration in the TGO epilayers was found to be highly dependent on growth conditions, and Ga flux in particular. First attempts to demonstrate vertical Schottky photodetectors using TGO epilayers on bulk n-type Ga2O3 substrates were successful. Resultant devices showed strong photoresponse to UV-C light with peak responsivities clearly red shifted in comparison to Ga2O3 homoepitaxial Schottky detectors due to TGO alloying.

  2. A microfabricated, low dark current a-Se detector for measurement of microplasma optical emission in the UV for possible use on-site

    NASA Astrophysics Data System (ADS)

    Abbaszadeh, Shiva; Karim, Karim S.; Karanassios, Vassili

    2013-05-01

    Traditionally, samples are collected on-site (i.e., in the field) and are shipped to a lab for chemical analysis. An alternative is offered by using portable chemical analysis instruments that can be used on-site (i.e., in the field). Many analytical measurements by optical emission spectrometry require use of light-sources and of spectral lines that are in the Ultra-Violet (UV, ~200 nm - 400 nm wavelength) region of the spectrum. For such measurements, a portable, battery-operated, fiber-optic spectrometer equipped with an un-cooled, linear, solid-state detector may be used. To take full advantage of the advanced measurement capabilities offered by state-of-the-art solid-state detectors, cooling of the detector is required. But cooling and other thermal management hamper portability and use on-site because they add size and weight and they increase electrical power requirements. To address these considerations, an alternative was implemented, as described here. Specifically, a microfabricated solid-state detector for measurement of UV photons will be described. Unlike solid-state detectors developed on crystalline Silicon, this miniaturized and low-cost detector utilizes amorphous Selenium (a-Se) as its photosensitive material. Due to its low dark current, this detector does not require cooling, thus it is better suited for portable use and for chemical measurements on-site. In this paper, a microplasma will be used as a light-source of UV photons for the a-Se detector. For example, spectra acquired using a microplasma as a light-source will be compared with those obtained with a portable, fiber-optic spectrometer equipped with a Si-based 2080-element detector. And, analytical performance obtained by introducing ng-amounts of analytes into the microplasma will be described.

  3. High-resolution pulse-counting array detectors for imaging and spectroscopy at ultraviolet wavelengths

    NASA Technical Reports Server (NTRS)

    Timothy, J. Gethyn; Bybee, Richard L.

    1986-01-01

    The performance characteristics of multianode microchannel array (MAMA) detector systems which have formats as large as 256 x 1024 pixels and which have application to imaging and spectroscopy at UV wavelengths are evaluated. Sealed and open-structure MAMA detector tubes with opaque CsI photocathodes can determine the arrival time of the detected photon to an accuracy of 100 ns or better. Very large format MAMA detectors with CsI and Cs2Te photocathodes and active areas of 52 x 52 mm (2048 x 2048 pixels) will be used as the UV solar blind detectors for the NASA STIS.

  4. Quantitative determination of ambroxol in tablets by derivative UV spectrophotometric method and HPLC.

    PubMed

    Dinçer, Zafer; Basan, Hasan; Göger, Nilgün Günden

    2003-04-01

    A derivative UV spectrophotometric method for the determination of ambroxol in tablets was developed. Determination of ambroxol in tablets was conducted by using first-order derivative UV spectrophotometric method at 255 nm (n = 5). Standards for the calibration graph ranging from 5.0 to 35.0 microg/ml were prepared from stock solution. The proposed method was accurate with 98.6+/-0.4% recovery value and precise with coefficient of variation (CV) of 1.22. These results were compared with those obtained by reference methods, zero-order UV spectrophotometric method and reversed-phase high-performance liquid chromatography (HPLC) method. A reversed-phase C(18) column with aqueous phosphate (0.01 M)-acetonitrile-glacial acetic acid (59:40:1, v/v/v) (pH 3.12) mobile phase was used and UV detector was set to 252 nm. Calibration solutions used in HPLC were ranging from 5.0 to 20.0 microg/ml. Results obtained by derivative UV spectrophotometric method was comparable to those obtained by reference methods, zero-order UV spectrophotometric method and HPLC, as far as ANOVA test, F(calculated) = 0.762 and F(theoretical) = 3.89, was concerned. Copyright 2003 Elsevier Science B.V.

  5. The research on a novel type of the solar-blind UV head-mounted displays

    NASA Astrophysics Data System (ADS)

    Zhao, Shun-long

    2011-08-01

    Ultraviolet technology of detecting is playing a more and more important role in the field of civil application, especially in the corona discharge detection, in modern society. Now the UV imaging detector is one of the most important equipments in power equipment flaws detection. And the modern head-mounted displays (HMDs) have shown the applications in the fields of military, industry production, medical treatment, entertainment, 3D visualization, education and training. We applied the system of head-mounted displays to the UV image detection, and a novel type of head-mounted displays is presented: the solar-blind UV head-mounted displays. And the structure is given. By the solar-blind UV head-mounted displays, a real-time, isometric and visible image of the corona discharge is correctly displayed upon the background scene where it exists. The user will see the visible image of the corona discharge on the real scene rather than on a small screen. Then the user can easily find out the power equipment flaws and repair them. Compared with the traditional UV imaging detector, the introducing of the HMDs simplifies the structure of the whole system. The original visible spectrum optical system is replaced by the eye in the solar-blind UV head-mounted displays. And the optical image fusion technology would be used rather than the digital image fusion system which is necessary in traditional UV imaging detector. That means the visible spectrum optical system and digital image fusion system are not necessary. This makes the whole system cheaper than the traditional UV imaging detector. Another advantage of the solar-blind UV head-mounted displays is that the two hands of user will be free. So while observing the corona discharge the user can do some things about it. Therefore the solar-blind UV head-mounted displays can make the corona discharge expose itself to the user in a better way, and it will play an important role in corona detection in the future.

  6. Detection of ultraviolet radiation using tissue equivalent radiochromic gel materials

    NASA Astrophysics Data System (ADS)

    Bero, M. A.; Abukassem, I.

    2009-05-01

    Ferrous Xylenol-orange Gelatin gel (FXG) is known to be sensitive to ionising radiation such as γ and X-rays. The effect of ionising radiation is to produce an increase in the absorption over a wide region of the visible spectrum, which is proportional to the absorbed dose. This study demonstrates that FXG gel is sensitive to ultraviolet radiation and therefore it could functions as UV detector. Short exposure to UV radiation produces linear increase in absorption measured at 550nm, however high doses of UV cause the ion indicator colour to fad away in a manner proportional to the incident UV energy. Light absorbance increase at the rate of 1.1% per minute of irradiation was monitored. The exposure level at which the detector has linear response is comparable to the natural summer UV radiation. Evaluating the UV ability to pass through tissue equivalent gel materials shows that most of the UV gets absorbed in the first 5mm of the gel materials, which demonstrate the damaging effects of this radiation type on human skin and eyes. It was concluded that FXG gel dosimeter has the potential to offer a simple, passive ultraviolet radiation detector with sensitivity suitable to measure and visualises the natural sunlight UV exposure directly by watching the materials colour changes.

  7. UV Spectroradiometric Output Of An F404 Turbojet Aircraft Engine

    NASA Astrophysics Data System (ADS)

    Schneider, William E.; Spaberg, Gordon H.

    1989-09-01

    Spectroradiometric measurements of the ultraviolet output of a GE F404 aircraft engine were made over the wavelength range of 200 to 320 nm. The tests were conducted at the GE Lynn, Mass. Riverworks facility in the F404 ram cell. The severe environmental conditions associated with the test cell required a special acoustical noise-proof and mechanical shock-proof enclosure for the double monochromator and UV detectors along with special long cabling to the externally located radiometer and automatic data reduction system. The tests successfully provided spectral irradiance measurements of the afterburner over the 225-320 nm wavelength range with a UV-enhanced silicon detector and over the 200-260 nm range with a PMT detector.

  8. The Austrian UV monitoring network

    NASA Astrophysics Data System (ADS)

    Blumthaler, Mario; Klotz, Barbara; Schwarzmann, Michael; Schreder, Josef

    2017-02-01

    The Austrian UV Monitoring network is operational since 1998 providing a large data set of erythemally weighted UV irradiance recorded with broadband UV biometer at 12 stations distributed all over Austria. In order to obtain high quality data all biometer are recalibrated once a year, the detectors are checked regularly for humidity and quality control is done routinely. The collected data are processed and then published on the website http://www.uv-index.at where the UV-Index of all measurement sites is presented in near real time together with a map of the distribution of the UV-Index over Austria. These UV-Index data together with measurements of global radiation and ozone levels from OMI are used to study long term trends for the stations of the monitoring network. Neither for all weather conditions nor for clear sky conditions is a statistically significant trend found for the UV-Index (with one exception) and for ozone. Furthermore, the radiation amplification factor (RAF) is determined experimentally from the power law correlation between UV-Index and ozone level for the site Innsbruck (577 m above sea level, 47.26°N, 11.38°E) for 19°solar elevation. A value of 0.91 ± 0.05 is found for the RAF for clear sky days with low ground albedo and a value of 1.03 ± 0.08 for days with high ground albedo (snow cover).

  9. RELEC Mission: Relativistic Electron Precipitation and TLE study on-board small spacecraft

    NASA Astrophysics Data System (ADS)

    Svertilov, Sergey

    The main goal of RELEC mission is studying of magnetosphere relativistic electron precipitation and its acting on the upper Atmosphere as well as transient luminous events (TLE) observation in wide range of electromagnetic spectrum. The RELEC set of instruments includes two identical detectors of X- and gamma-rays of high temporal resolution and sensitivity (DRGE-1 & DRGE-2), three axe directed detectors of energetic electrons and protons DRGE-3, UV TLE imager MTEL, UV detector DUV, low-frequency analyser LFA, radio-frequency analyser RFA, module of electronics intended for commands and data collection BE. During the RELEC mission following experiments will be provided: - simultaneous observations of energetic electron & proton flux (energy range ~0.1-10.0 MeV and low-frequency (~0.1-10 kHz) electromagnetic wave field intensity variations with high temporal resolution (~1 ms); - fine time structure (~1 mcs) measurements of transient atmospheric events in UV, X- and gamma rays with a possibility of optical imaging with resolution of ~km in wide FOV; - measurements of electron flux pitch-angle distribution in dynamical range from ~0.1 up to 105 part/cm2s; - monitoring of charge and neutral background particles in different areas of near-Earth space. Now the all RELEC instruments are installed on-board small spacecraft manufactured by Lavochkin space corporation. The launch is scheduled on May, 2014 as by-pass mission with Meteor spacecraft. The RELEC mission orbit is planned to be quasi-circular solar-synchronous with about 700 km height. The total volume of transmitted data is about 1.2 Gbyte per day.

  10. Microchannel plate detector technology potential for LUVOIR and HabEx

    NASA Astrophysics Data System (ADS)

    Siegmund, O. H. W.; Ertley, C.; Vallerga, J. V.; Schindhelm, E. R.; Harwit, A.; Fleming, B. T.; France, K. C.; Green, J. C.; McCandliss, S. R.; Harris, W. M.

    2017-08-01

    Microchannel plate (MCP) detectors have been the detector of choice for ultraviolet (UV) instruments onboard many NASA missions. These detectors have many advantages, including high spatial resolution (<20 μm), photon counting, radiation hardness, large formats (up to 20 cm), and ability for curved focal plane matching. Novel borosilicate glass MCPs with atomic layer deposition combine extremely low backgrounds, high strength, and tunable secondary electron yield. GaN and combinations of bialkali/alkali halide photocathodes show promise for broadband, higher quantum efficiency. Cross-strip anodes combined with compact ASIC readout electronics enable high spatial resolution over large formats with high dynamic range. The technology readiness levels of these technologies are each being advanced through research grants for laboratory testing and rocket flights. Combining these capabilities would be ideal for UV instruments onboard the Large UV/Optical/IR Surveyor (LUVOIR) and the Habitable Exoplanet Imaging Mission (HABEX) concepts currently under study for NASA's Astrophysics Decadal Survey.

  11. TCPD: A micropattern photon detector hybrid for RICH applications

    NASA Astrophysics Data System (ADS)

    Hamar, G.; Varga, D.

    2017-03-01

    A micropattern and wire chamber hybrid has been constructed for UV photon detection, and its performance evaluated. It is revealed that such combination retains some key advantages of both the Thick-GEM primary and CCC secondary amplification stages, and results in a high gain gaseous photon detector with outstanding stability. Key features such as MIP suppression, detection efficiency and photon cluster size are discussed. The capability of the detector for UV photon detection has been established and proven with Cherenkov photons in particle beam tests.

  12. Investigating the Implementation of ZnO Nanoparticles as a Tunable UV Detector for Different Skin Types

    NASA Astrophysics Data System (ADS)

    Mosayebi, Pegah; Dorranian, Davoud; Behzad, Kasra

    A facile chemical reduction method was used to synthesize ZnO nanoparticles (NPs) in ethylene glycol solvent at two different calcination temperatures. As a result of variation in the calcination temperature, ZnO NPs with two different sizes were achieved. The NPs were investigated for their structural and optical characteristics using X-ray diffraction and ultraviolet (UV)-Vis spectroscopy. The synthesized ZnO NPs exhibited a hexagonal structure with sizes of 46 and 65nm. The synthesized NPs were then used to investigate dye photocatalytic behavior of products as a tunable UV detector for different skin types. The dye degradation and decolorization of methylene blue in the presence of ZnO NP, following UV radiation as a function of time, were studied at different pH levels. The optical absorption spectra were then taken every 15min for all samples. The UV-Vis spectroscopy spectra revealed that optical absorption of solution was decreased upon UV exposure as a function of time. Photocatalytic reaction indicated that the dye degradation and decolorization rate were accelerated with the increase of pH level. Therefore, a tunable UV detector for different skin types could be engineered by varying the pH level of solution to avoid human skin burning.

  13. Inspection of feasible calibration conditions for UV radiometer detectors with the KI/KIO3 actinometer.

    PubMed

    Qiang, Zhimin; Li, Wentao; Li, Mengkai; Bolton, James R; Qu, Jiuhui

    2015-01-01

    UV radiometers are widely employed for irradiance measurements, but their periodical calibrations not only induce an extra cost but also are time-consuming. In this study, the KI/KIO3 actinometer was applied to calibrate UV radiometer detectors at 254 nm with a quasi-collimated beam apparatus equipped with a low-pressure UV lamp, and feasible calibration conditions were identified. Results indicate that a washer constraining the UV light was indispensable, while the size (10 or 50 mL) of a beaker containing the actinometer solution had little influence when a proper washer was used. The absorption or reflection of UV light by the internal beaker wall led to an underestimation or overestimation of the irradiance determined by the KI/KIO3 actinometer, respectively. The proper range of the washer internal diameter could be obtained via mathematical analysis. A radiometer with a longer service time showed a greater calibration factor. To minimize the interference from the inner wall reflection of the collimating tube, calibrations should be conducted at positions far enough away from the tube bottom. This study demonstrates that after the feasible calibration conditions are identified, the KI/KIO3 actinometer can be applied readily to calibrate UV radiometer detectors at 254 nm. © 2014 The American Society of Photobiology.

  14. Ultrafast, superhigh gain visible-blind UV detector and optical logic gates based on nonpolar a-axial GaN nanowire

    NASA Astrophysics Data System (ADS)

    Wang, Xingfu; Zhang, Yong; Chen, Xinman; He, Miao; Liu, Chao; Yin, Yian; Zou, Xianshao; Li, Shuti

    2014-09-01

    Nonpolar a-axial GaN nanowire (NW) was first used to construct the MSM (metal-semiconductor-metal) symmetrical Schottky contact device for application as visible-blind ultraviolet (UV) detector. Without any surface or composition modifications, the fabricated device demonstrated a superior performance through a combination of its high sensitivity (up to 104 A W-1) and EQE value (up to 105), as well as ultrafast (<26 ms) response speed, which indicates that a balance between the photocurrent gain and the response speed has been achieved. Based on its excellent photoresponse performance, an optical logic AND gate and OR gate have been demonstrated for performing photo-electronic coupled logic devices by further integrating the fabricated GaN NW detectors, which logically convert optical signals to electrical signals in real time. These results indicate the possibility of using a nonpolar a-axial GaN NW not only as a high performance UV detector, but also as a stable optical logic device, both in light-wave communications and for future memory storage.Nonpolar a-axial GaN nanowire (NW) was first used to construct the MSM (metal-semiconductor-metal) symmetrical Schottky contact device for application as visible-blind ultraviolet (UV) detector. Without any surface or composition modifications, the fabricated device demonstrated a superior performance through a combination of its high sensitivity (up to 104 A W-1) and EQE value (up to 105), as well as ultrafast (<26 ms) response speed, which indicates that a balance between the photocurrent gain and the response speed has been achieved. Based on its excellent photoresponse performance, an optical logic AND gate and OR gate have been demonstrated for performing photo-electronic coupled logic devices by further integrating the fabricated GaN NW detectors, which logically convert optical signals to electrical signals in real time. These results indicate the possibility of using a nonpolar a-axial GaN NW not only as a high performance UV detector, but also as a stable optical logic device, both in light-wave communications and for future memory storage. Electronic supplementary information (ESI) available: Details of the EDS and SAED data, supplementary results of the UV detector, and the discussion of the transport properties of the MSM Schottky contact devices. See DOI: 10.1039/c4nr03581j

  15. Alternative glues for the production of ATLAS silicon strip modules for the Phase-II upgrade of the ATLAS Inner Detector

    NASA Astrophysics Data System (ADS)

    Poley, L.; Bloch, I.; Edwards, S.; Friedrich, C.; Gregor, I.-M.; Jones, T.; Lacker, H.; Pyatt, S.; Rehnisch, L.; Sperlich, D.; Wilson, J.

    2016-05-01

    The Phase-II upgrade of the ATLAS detector for the High Luminosity Large Hadron Collider (HL-LHC) includes the replacement of the current Inner Detector with an all-silicon tracker consisting of pixel and strip detectors. The current Phase-II detector layout requires the construction of 20,000 strip detector modules consisting of sensor, circuit boards and readout chips, which are connected mechanically using adhesives. The adhesive used initially between readout chips and circuit board is a silver epoxy glue as was used in the current ATLAS SemiConductor Tracker (SCT). However, this glue has several disadvantages, which motivated the search for an alternative. This paper presents a study of six ultra-violet (UV) cure glues and a glue pad for possible use in the assembly of silicon strip detector modules for the ATLAS upgrade. Trials were carried out to determine the ease of use, thermal conduction and shear strength. Samples were thermally cycled, radiation hardness and corrosion resistance were also determined. These investigations led to the exclusion of three UV cure glues as well as the glue pad. Three UV cure glues were found to be possible better alternatives than silver loaded glue. Results from electrical tests of first prototype modules constructed using these glues are presented.

  16. High-efficiency UV/optical/NIR detectors for large aperture telescopes and UV explorer missions: development of and field observations with delta-doped arrays

    NASA Astrophysics Data System (ADS)

    Nikzad, Shouleh; Jewell, April D.; Hoenk, Michael E.; Jones, Todd J.; Hennessy, John; Goodsall, Tim; Carver, Alexander G.; Shapiro, Charles; Cheng, Samuel R.; Hamden, Erika T.; Kyne, Gillian; Martin, D. Christopher; Schiminovich, David; Scowen, Paul; France, Kevin; McCandliss, Stephan; Lupu, Roxana E.

    2017-07-01

    Exciting concepts are under development for flagship, probe class, explorer class, and suborbital class NASA missions in the ultraviolet/optical spectral range. These missions will depend on high-performance silicon detector arrays being delivered affordably and in high numbers. To that end, we have advanced delta-doping technology to high-throughput and high-yield wafer-scale processing, encompassing a multitude of state-of-the-art silicon-based detector formats and designs. We have embarked on a number of field observations, instrument integrations, and independent evaluations of delta-doped arrays. We present recent data and innovations from JPL's Advanced Detectors and Systems Program, including two-dimensional doping technology, JPL's end-to-end postfabrication processing of high-performance UV/optical/NIR arrays and advanced coatings for detectors. While this paper is primarily intended to provide an overview of past work, developments are identified and discussed throughout. Additionally, we present examples of past, in-progress, and planned observations and deployments of delta-doped arrays.

  17. AlGaN Ultraviolet Detectors for Dual-Band UV Detection

    NASA Technical Reports Server (NTRS)

    Miko, Laddawan; Franz, David; Stahle, Carl M.; Yan, Feng; Guan, Bing

    2010-01-01

    This innovation comprises technology that has the ability to measure at least two ultraviolet (UV) bands using one detector without relying on any external optical filters. This allows users to build a miniature UVA and UVB monitor, as well as to develop compact, multicolor imaging technologies for flame temperature sensing, air-quality control, and terrestrial/counter-camouflage/biosensing applications.

  18. Development of a ginkgo biloba fingerprint chromatogram with UV and evaporative light scattering detection and optimization of the evaporative light scattering detector operating conditions.

    PubMed

    van Nederkassel, A M; Vijverman, V; Massart, D L; Vander Heyden, Y

    2005-09-02

    A fingerprint chromatogram of a standardized Ginkgo biloba extract is developed on a monolithic silica column using a ternary gradient containing water, iso-propanol and tetrahydrofuran. For the detection, UV and evaporative light scattering (ELS) detectors are used, the latter allowing detection of the poor UV absorbing compounds as ginkgolides (A-C and J) and bilobalide in the extract. The complementary information between the UV and ELS fingerprint is evaluated. The ELS detector used in this study can operate in an impactor 'on' or 'off' mode. For each mode, the operating conditions such as the nebulizing gas flow rate, the drift tube temperature and the gain are optimized by use of three-level screening designs to obtain the best signal-to-noise (S/N) ratio in the final ELS fingerprint chromatogram. In both impactor modes, very similar S/N ratios are obtained for the nominal levels of the design. However, optimization of the operating conditions resulted, for both impactor modes, in a significant increase in S/N ratios compared to the initial evaluated conditions, obtained from the detector software.

  19. ZnO nanoneedle/H2O solid-liquid heterojunction-based self-powered ultraviolet detector

    PubMed Central

    2013-01-01

    ZnO nanoneedle arrays were grown vertically on a fluorine-doped tin oxide-coated glass by hydrothermal method at a relatively low temperature. A self-powered photoelectrochemical cell-type UV detector was fabricated using the ZnO nanoneedles as the active photoanode and H2O as the electrolyte. This solid-liquid heterojunction offers an enlarged ZnO/water contact area and a direct pathway for electron transport simultaneously. By connecting this UV photodetector to an ammeter, the intensity of UV light can be quantified using the output short-circuit photocurrent without a power source. High photosensitivity, excellent spectral selectivity, and fast photoresponse at zero bias are observed in this UV detector. The self-powered behavior can be well explained by the formation of a space charge layer near the interface of the solid-liquid heterojunction, which results in a built-in potential and makes the solid-liquid heterojunction work in photovoltaic mode. PMID:24103153

  20. Detection of UV Pulse from Insulators and Application in Estimating the Conditions of Insulators

    NASA Astrophysics Data System (ADS)

    Wang, Jingang; Chong, Junlong; Yang, Jie

    2014-10-01

    Solar radiation in the band of 240-280 nm is absorbed by the ozone layer in the atmosphere, and corona discharges from high-voltage apparatus emit in air mainly in the 230-405 nm range of ultraviolet (UV), so the band of 240-280 nm is called UV Solar Blind Band. When the insulators in a string deteriorate or are contaminated, the voltage distribution along the string will change, which causes the electric fields in the vicinity of insulators change and corona discharge intensifies. An UV pulse detection method to check the conditions of insulators is presented based on detecting the UV pulse among the corona discharge, then it can be confirmed that whether there exist faulty insulators and whether the surface contamination of insulators is severe for the safe operation of power systems. An UV-I Insulator Detector has been developed, and both laboratory tests and field tests have been carried out which demonstrates the practical viability of UV-I Insulator Detector for online monitoring.

  1. Performance evaluation of bottom gate ZnO based thin film transistors with different W/L ratios for UV sensing

    NASA Astrophysics Data System (ADS)

    Varma, Tarun; Periasamy, C.; Boolchandani, Dharmendar

    2018-02-01

    In this paper, we report the simulation, fabrication and characterisation of UV photo-detectors with bottom gate ZnO Thin Film Transistors (TFTs), grown on silicon at room temperature using RF magnetron sputtering process. The static performance of these detectors have been explored by varying the channel lengths (6 μm and 12 μm). The fabricated devices show low leakage currents with threshold voltages of 1.18 & 2.33 V, sub-threshold swings of 13.5 & 12.8 V/dec for channel lengths of 6 μm and 12 μm TFT, respectively. They also exhibit superior electrical characteristics with an ON-OFF ratio of the order of 3. The detector was also tested for device stability, with the transfer characteristics of the TFTs, which got deteriorated mainly by the negative bias-stress. The TFTs were further tested for UV detector applications and found to exhibit good photo-response.

  2. Reverse phase high performance liquid chromatographic method development based on ultravioletvisible detector for the analysis of 1-hydroxypyrene (PAH biomarker) in human urine.

    PubMed

    Kamal, Atif; Gulfraz, Mohammad; Anwar, Mohammad Asad; Malik, Riffat Naseem

    2015-01-01

    1-hydroxypyrene is an important biomarker of exposure to polycyclic aromatic hydrocarbons (PAHs), which appears in the urine of exposed human subjects. In developing countries, where advanced instruments are not available, the importance of this biomarker demands convenient and sensitive methods for determination purposes. This study aimed at developing a methodology to quantify 1-hydroxypyrene (a biomarker of PAHs exposure) based on the UV-visible detector in the reverse phase high pressure liquid chromatography (HPLC). A 20 μl injection of sample was used for manual injection into the HPLC Shimadzu, equipped with the SPD-20 A UV-visible detector, the LC-20AT pump and the DGU-20A5 degasser. The C-18 column was used for the purpose of the analysis. The method showed a good linearity (the range: R2 = 0.979-0.989), and high detectability up to the nmol level. The average retention was 6.37, with the accuracy of 2%, and the percentage of recovery remained 108%. The overall performance of this method was comparable (in terms of detection sensitivity) and relatively better than previously reported studies using the HPLC system equipped with the UV-detector. This method is suitable and reliable for the detection/quantification of the 1-OHP in human urine samples, using the UV-detector, however, it is less sensitive as compared to the results of a florescence detector. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  3. MCP detector development for UV space missions

    NASA Astrophysics Data System (ADS)

    Conti, Lauro; Barnstedt, Jürgen; Hanke, Lars; Kalkuhl, Christoph; Kappelmann, Norbert; Rauch, Thomas; Stelzer, Beate; Werner, Klaus; Elsener, Hans-Rudolf; Schaadt, Daniel M.

    2018-04-01

    We are developing imaging and photon counting UV-MCP detectors, which are sensitive in the wavelength range from far ultraviolet to near ultraviolet. A good quantum efficiency, solar blindness and high spatial resolution is the aim of our development. The sealed detector has a Cs-activated photoactive layer of GaN (or similarly advanced photocathode), which is operated in semitransparent mode on (001)-MgF2. The detector comprises a stack of two long-life MCPs and a coplanar cross strip anode with advanced readout electronics. The main challenge is the flawless growth of the GaN photocathode layer as well as the requirements for the sealing of the detector, to prevent a degradation of the photocathode. We present here the detector concept and the experimental setup, examine in detail the status in the production and describe the current status of the readout electronics development.

  4. Absorbance detector for high performance liquid chromatography based on a deep-UV light-emitting diode at 235nm.

    PubMed

    da Silveira Petruci, João Flavio; Liebetanz, Michael G; Cardoso, Arnaldo Alves; Hauser, Peter C

    2017-08-25

    In this communication, we describe a flow-through optical absorption detector for HPLC using for the first time a deep-UV light-emitting diode with an emission band at 235nm as light source. The detector is also comprised of a UV-sensitive photodiode positioned to enable measurement of radiation through a flow-through cuvette with round aperture of 1mm diameter and optical path length of 10mm, and a second one positioned as reference photodiode; a beam splitter and a power supply. The absorbance was measured and related to the analyte concentration by emulating the Lambert-Beer law with a log-ratio amplifier circuitry. This detector showed noise levels of 0.30mAU, which is comparable with our previous LED-based detectors employing LEDs at 280 and 255nm. The detector was coupled to a HPLC system and successfully evaluated for the determination of the anti-diabetic drugs pioglitazone and glimepiride in an isocratic separation and the benzodiazepines flurazepam, oxazepam and clobazam in a gradient elution. Good linearities (r>0.99), a precision better than 0.85% and limits of detection at sub-ppm levels were achieved. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. UV LED-based lightweight fixed-wavelength detector: for the development of a miniaturized high-performance liquid chromatography (HPLC) system (Erratum)

    NASA Astrophysics Data System (ADS)

    Guan, Wen Yin; Lee, Wei Yan; Liew, Mervyn Wing On; Tan, Soo Choon; Lim, Jit Kang

    2018-02-01

    Publisher's Note: This paper, originally published on 14 February, 2018, was replaced with a corrected/revised version on 30 March, 2018. If you downloaded the original PDF but are unable to access the revision, please contact SPIE Digital Library Customer Service for assistance. General discussion on the development of portable and miniaturized instrumentation for High Performance Liquid Chromatography (HPLC) is given, specifically the design of UV absorbance detector for field applications. UV/Vis absorption detectors are the most commonly used detector in HPLC for the identification of organic compounds, detection of peptides, proteins and nucleic acids. Opportunities for miniaturization arise from trends which focus on ease of use, portability, and application-specific instruments for example in environmental applications - detection of phenols (water pollutant) and contaminants. Further usage is such as detection of polycyclic aromatic hydrocarbons (PAHs) and carcinogens in edible oils and growth promoter residues in meat. Significant improvement in size and complexity were realized using a simplified optical configuration, efficient low-power LED driver circuit and detector electronics. Firstly, the detector's optical configuration is discussed as an essential part of the miniature fixed-wavelength design. UV-LED with different wavelengths can be installed interchangeably without the need for complicated assembly and precise alignment process. In the second part, each functional block of the detector hardware design are also discussed. The electronics consist of mainly sample photodiode and reference photodiode, Log-ratio amplifier and signal conditioning electronics built with precision analog design techniques and low-noise electronic components. Finally, baseline noise and drift measurements and chromatography performance are presented and the results are compared with conventional detector under identical conditions as benchmark. The advantages of miniaturized HPLC system are portability for onsite analysis, increased efficiency, lower solvent requirements and fully integrated separation and detection system.

  6. OP09O-OP404-9 Wide Field Camera 3 CCD Quantum Efficiency Hysteresis

    NASA Technical Reports Server (NTRS)

    Collins, Nick

    2009-01-01

    The HST/Wide Field Camera (WFC) 3 UV/visible channel CCD detectors have exhibited an unanticipated quantum efficiency hysteresis (QEH) behavior. At the nominal operating temperature of -83C, the QEH feature contrast was typically 0.1-0.2% or less. The behavior was replicated using flight spare detectors. A visible light flat-field (540nm) with a several times full-well signal level can pin the detectors at both optical (600nm) and near-UV (230nm) wavelengths, suppressing the QEH behavior. We are characterizing the timescale for the detectors to become unpinned and developing a protocol for flashing the WFC3 CCDs with the instrument's internal calibration system in flight. The HST/Wide Field Camera 3 UV/visible channel CCD detectors have exhibited an unanticipated quantum efficiency hysteresis (QEH) behavior. The first observed manifestation of QEH was the presence in a small percentage of flat-field images of a bowtie-shaped contrast that spanned the width of each chip. At the nominal operating temperature of -83C, the contrast observed for this feature was typically 0.1-0.2% or less, though at warmer temperatures contrasts up to 5% (at -50C) have been observed. The bowtie morphology was replicated using flight spare detectors in tests at the GSFC Detector Characterization Laboratory by power cycling the detector while cold. Continued investigation revealed that a clearly-related global QE suppression at the approximately 5% level can be produced by cooling the detector in the dark; subsequent flat-field exposures at a constant illumination show asymptotically increasing response. This QE "pinning" can be achieved with a single high signal flat-field or a series of lower signal flats; a visible light (500-580nm) flat-field with a signal level of several hundred thousand electrons per pixel is sufficient for QE pinning at both optical (600nm) and near-UV (230nm) wavelengths. We are characterizing the timescale for the detectors to become unpinned and developing a protocol for flashing the WFC3 CCDs with the instrument's internal calibration system in flight. A preliminary estimate of the decay timescale for one detector is that a drop of 0.1-0.2% occurs over a ten day period, indicating that relatively infrequent cal lamp exposures can mitigate the behavior to extremely low levels.

  7. On-Site Determination and Monitoring of Real-Time Fluence Delivery for an Operating UV Reactor Based on a True Fluence Rate Detector.

    PubMed

    Li, Mengkai; Li, Wentao; Qiang, Zhimin; Blatchley, Ernest R

    2017-07-18

    At present, on-site fluence (distribution) determination and monitoring of an operating UV system represent a considerable challenge. The recently developed microfluorescent silica detector (MFSD) is able to measure the approximate true fluence rate (FR) at a fixed position in a UV reactor that can be compared with a FR model directly. Hence it has provided a connection between model calculation and real-time fluence determination. In this study, an on-site determination and monitoring method of fluence delivery for an operating UV reactor was developed. True FR detectors, a UV transmittance (UVT) meter, and a flow rate meter were used for fundamental measurements. The fluence distribution, as well as reduction equivalent fluence (REF), 10th percentile dose in the UV fluence distribution (F 10 ), minimum fluence (F min ), and mean fluence (F mean ) of a test reactor, was calculated in advance by the combined use of computational fluid dynamics and FR field modeling. A field test was carried out on the test reactor for disinfection of a secondary water supply. The estimated real-time REF, F 10 , F min , and F mean decreased 73.6%, 71.4%, 69.6%, and 72.9%, respectively, during a 6-month period, which was attributable to lamp output attenuation and sleeve fouling. The results were analyzed with synchronous data from a previously developed triparameter UV monitoring system and water temperature sensor. This study allowed demonstration of an accurate method for on-site, real-time fluence determination which could be used to enhance the security and public confidence of UV-based water treatment processes.

  8. A novel liquid-Xenon detector concept for combined fast-neutrons and gamma imaging and spectroscopy

    NASA Astrophysics Data System (ADS)

    Breskin, A.; Israelashvili, I.; Cortesi, M.; Arazi, L.; Shchemelinin, S.; Chechik, R.; Dangendorf, V.; Bromberger, B.; Vartsky, D.

    2012-06-01

    A new detector concept is presented for combined imaging and spectroscopy of fast-neutrons and gamma rays. It comprises a liquid-Xenon (LXe) converter and scintillator coupled to a UV-sensitive gaseous imaging photomultiplier (GPM). Radiation imaging is obtained by localization of the scintillation-light from LXe with the position-sensitive GPM. The latter comprises a cascade of Thick Gas Electron Multipliers (THGEM), where the first element is coated with a CsI UV-photocathode. We present the concept and provide first model-simulation results of the processes involved and the expected performances of a detector having a LXe-filled capillaries converter. The new detector concept has potential applications in combined fast-neutron and gamma-ray screening of hidden explosives and fissile materials with pulsed sources.

  9. Ultraporous Electron-Depleted ZnO Nanoparticle Networks for Highly Sensitive Portable Visible-Blind UV Photodetectors.

    PubMed

    Nasiri, Noushin; Bo, Renheng; Wang, Fan; Fu, Lan; Tricoli, Antonio

    2015-08-05

    A hierarchical nano- and microstructured morphology for visible-blind UV photo-detectors is developed, which provides record-high milliampere photocurrents, nanoampere dark currents, and excellent selectivity to ultralow UV light intensities. This is a significant step toward the integration of high-performance UV photodetectors in wearable devices. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Microchannel detector array for X-rays and UV

    NASA Technical Reports Server (NTRS)

    Timothy, J. G.; Bybee, R. L.

    1976-01-01

    Device employs sensitive photoelectric electrodes and solid-state memory, can be used at visible UV and X ray wavelengths, includes nonmagnetic proximity focusing, and is immune to high energy charged-particle background.

  11. Demonstration of zero bias responsivity in MBE grown β-Ga2O3 lateral deep-UV photodetector

    NASA Astrophysics Data System (ADS)

    Singh Pratiyush, Anamika; Krishnamoorthy, Sriram; Kumar, Sandeep; Xia, Zhanbo; Muralidharan, Rangarajan; Rajan, Siddharth; Nath, Digbijoy N.

    2018-06-01

    We demonstrate zero-bias spectral responsivity in MBE-grown β-Ga2O3 planar UV-C detector with good linearity up to optical power density of 4.6 mW cm‑2. Devices with asymmetrical metal contacts were realized on 150 nm thick β-Ga2O3 films on sapphire. The device exhibited a spectral responsivity of 1.4 mA W‑1 at 255 nm under zero-bias condition, dark current <10 nA at 15 V and UV-to-visible rejection ratio ∼105 at 5 V. The demonstrated UV-C detector exhibited an estimated high detectivity of 2.0 × 1012 Jones at 1 V and were found to be very stable and repeatable, suggesting its potential use for focal plane arrays.

  12. Early Results from TUS, the First Orbital Detector of Extreme Energy Cosmic Rays

    NASA Astrophysics Data System (ADS)

    Zotov, Mikhail

    TUS is the world's first orbital detector of extreme energy cosmic rays (EECRs), which operates as a part of the scientific payload of the Lomonosov satellite since May 19, 2016. TUS employs the nocturnal atmosphere of the Earth to register ultraviolet (UV) fluorescence and Cherenkov radiation from extensive air showers generated by EECRs as well as UV radiation from lightning strikes and transient luminous events, micro-meteors and space debris. The first months of its operation in orbit have demonstrated an unexpectedly rich variety of UV radiation in the atmosphere. We briefly review the design of TUS and present a few examples of events recorded in a mode dedicated to registering EECRs.

  13. In-flight performance of the solar UV radiometer LYRA/PROBA-2

    NASA Astrophysics Data System (ADS)

    Stockman, Y.; BenMoussa, A.; Dammasch, I.; Defise, J.-M.; Dominique, M.; Halain, J.-P.; Hochedez, J.-F.; Koller, S.; Schmutz, W.; Schühle, U.

    2017-11-01

    LYRA is a solar radiometer, part of the PROBA-2 micro-satellite payload (Fig. 1). The PROBA-2 [1] mission has been launched on 02 November 2009 with a Rockot launcher to a Sun-synchronous orbit at an altitude of 725 km. Its nominal operation duration is two years with possible extension of 2 years. PROBA-2 is a small satellite developed under an ESA General Support Technology Program (GSTP) contract to perform an in-flight demonstration of new space technologies and support a scientific mission for a set of selected instruments [2]. PROBA-2 host 17 technological demonstrators and 4 scientific instruments. The mission is tracked by the ESA Redu Mission Operation Center. One of the four scientific instruments is LYRA that monitors the solar irradiance at a high cadence (> 20 Hz) in four soft X-Ray to VUV large passbands: the "Lyman-Alpha" channel, the "Herzberg" continuum range, the "Aluminium" and "Zirconium" filter channels. The radiometric calibration is traceable to synchrotron source standards [3]. LYRA benefits from wide bandgap detectors based on diamond. It is the first space assessment of these revolutionary UV detectors for astrophysics. Diamond sensors make the instruments radiation-hard and solar-blind (insensitive to the strong solar visible light) and, therefore, visible light blocking filters become superfluous. To correlate the data of this new detector technology, silicon detectors with well known characteristics are also embarked. Due to the strict allocated mass and power budget (5 kg, 5W), and poor priority to the payload needs on such platform, an optimization and a robustness of the instrument was necessary. The first switch-on occured on 16 November 2009. Since then the instrument performances have been monitored and analyzed during the commissioning period. This paper presents the first-light and preliminary performance analysis.

  14. Pulsed UV laser-induced modifications in optical and structural characteristics of alpha-irradiated PM-355 SSNTD.

    PubMed

    Alghamdi, S S; Farooq, W A; Baig, M R; Algarawi, M S; Alrashidi, Talal Mohammed; Ali, Syed Mansoor; Alfaramawi, K

    2017-10-01

    Pre- and postalpha-exposed PM-355 detectors were irradiated using UV laser with different number of pulses (100, 150, 200, 300, and 400). UV laser beam energy of 20mJ per pulse with a pulse width of 9ns was incident on an area of 19.6mm 2 of the samples. XRD spectra indicated that for both reference and UV-irradiated samples, the structure is amorphous, but the crystallite size increases upon UV irradiation. The same results were obtained from SEM analysis. Optical properties of PM-355 polymeric solid-state nuclear track detectors were also investigated. Absorbance measurements for all PM-355 samples in the range of 200-400nm showed that the absorption edge had a blue shift up to a certain value, and then, it had an oscillating behavior. Photoluminescence spectra of PM-355 at 250nm revealed a decrease in the broadband peak intensity as a function of the number of UV pulses, while the wavelengths corresponding to the peaks had random shifts. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Fast Solar-Blind AlGaN/GaN 2DEG UV detector with Transparent Graphene Electrode

    DTIC Science & Technology

    2017-03-01

    graphene and 2D electron gas (2DEG). With introducing the graphene, photo-carriers separated by the polarization electric field of the AlGaN are...photodiodes, due to the strong intrinsic polarization effect of AlGaN. More than 105 of high signal to noise ratio of the UV detectors with fast...intrinsic polarization field vertically inside the AlGaN, the holes and electrons will travel in their shortest paths to graphene and 2DEG

  16. Hybrid AlGaN-SiC Avalanche Photodiode for Deep-UV Photon Detection

    NASA Technical Reports Server (NTRS)

    Aslam, Shahid; Herrero, Federico A.; Sigwarth, John; Goldsman, Neil; Akturk, Akin

    2010-01-01

    The proposed device is capable of counting ultraviolet (UV) photons, is compatible for inclusion into space instruments, and has applications as deep- UV detectors for calibration systems, curing systems, and crack detection. The device is based on a Separate Absorption and Charge Multiplication (SACM) structure. It is based on aluminum gallium nitride (AlGaN) absorber on a silicon carbide APD (avalanche photodiode). The AlGaN layer absorbs incident UV photons and injects photogenerated carriers into an underlying SiC APD that is operated in Geiger mode and provides current multiplication via avalanche breakdown. The solid-state detector is capable of sensing 100-to-365-nanometer wavelength radiation at a flux level as low as 6 photons/pixel/s. Advantages include, visible-light blindness, operation in harsh environments (e.g., high temperatures), deep-UV detection response, high gain, and Geiger mode operation at low voltage. Furthermore, the device can also be designed in array formats, e.g., linear arrays or 2D arrays (micropixels inside a superpixel).

  17. Accelerating CR-39 Track Detector Processing by Utilizing UV

    NASA Astrophysics Data System (ADS)

    Sparling, Jonathan; Padalino, Stephen; McLean, James; Sangster, Craig; Regan, Sean

    2017-10-01

    The use of CR-39 plastic as a Solid State Nuclear Track Detector is an effective technique for obtaining data in high energy particle experiments including inertial confinement fusion. To reveal particle tracks after irradiation, CR-39 is chemically etched in NaOH at 80°C, producing micron-scale signal pits at the nuclear track sites. It has been shown that illuminating CR-39 with UV light prior to etching increases bulk and track etch rates, especially when combined with elevated temperature. Spectroscopic analysis for amorphous solids has helped identify which UV wavelengths are most effective at enhancing etch rates. Absorption peaks found in the near infrared range provide for efficient sample heating, and may allow targeting cooperative IR-UV chemistry. Avoiding UV induced noise can be achieved through variations in absorption depths with wavelength. Vacuum drying and water absorption tests allow measurement of the resulting variation of bulk etch rate with depth. Funded in part by the NSF and an Department of Energy Grant through the Lab of Laser Energetics.

  18. A ZnO nanowire-based photo-inverter with pulse-induced fast recovery.

    PubMed

    Raza, Syed Raza Ali; Lee, Young Tack; Hosseini Shokouh, Seyed Hossein; Ha, Ryong; Choi, Heon-Jin; Im, Seongil

    2013-11-21

    We demonstrate a fast response photo-inverter comprised of one transparent gated ZnO nanowire field-effect transistor (FET) and one opaque FET respectively as the driver and load. Under ultraviolet (UV) light the transfer curve of the transparent gate FET shifts to the negative side and so does the voltage transfer curve (VTC) of the inverter. After termination of UV exposure the recovery of photo-induced current takes a long time in general. This persistent photoconductivity (PPC) is due to hole trapping on the surface of ZnO NWs. Here, we used a positive voltage short pulse after UV exposure, for the first time resolving the PPC issue in nanowire-based photo-detectors by accumulating electrons at the ZnO/dielectric interface. We found that a pulse duration as small as 200 ns was sufficient to reach a full recovery to the dark state from the UV induced state, realizing a fast UV detector with a voltage output.

  19. Multiple-channel ultra-violet absorbance detector for two-dimensional chromatographic separations.

    PubMed

    Lynch, Kyle B; Yang, Yu; Ren, Jiangtao; Liu, Shaorong

    2018-05-01

    In recent years, much research has gone into developing online comprehensive two-dimensional liquid chromatographic systems allowing for high peak capacities in comparable separation times to that of one-dimensional liquid chromatographic systems. However, the speed requirements in the second dimension (2nd-D) still remain one challenge for complex biological samples due to the current configuration of two column/two detector systems. Utilization of multiple 2nd-D columns can mitigate this challenge. To adapt this approach, we need a multiple channel detector. Here we develop a versatile multichannel ultraviolet (UV) light absorbance detector that is capable of simultaneously monitoring separations in 12 columns. The detector consists of a deuterium lighthouse, a flow cell assembly (a 13-channel flow cell fitted with a 13-photodiode-detection system), and a data acquisition and monitoring terminal. Through the use of a custom high optical quality furcated fiber to improve light transmission, precise machining of a flow cell to reduce background stray light through precision alignment, and sensitive electronic circuitry to reduce electronic noise through an active low pass filter, the background noise level is measured in the tens of µAU. We obtain a linear dynamic range of close to three orders of magnitude. Compared to a commercialized multichannel UV light absorbance detector like the Waters 2488 UV/Vis, our device provides an increase in channel detection while residing within the same noise region and linear range. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Optical Diagnostics of Multi-Gap Gas Switches for Linear Transformer Drivers

    NASA Astrophysics Data System (ADS)

    Sheng, Liang; Li, Yang; Sun, Tieping; Cong, Peitian; Zhang, Mei; Peng, Bodong; Zhao, Jizhen; Yue, Zhiqin; Wei, Fuli; Yuan, Yuan

    2014-07-01

    The trigger characteristics of a multi-gap gas switch with double insulating layers, a square-groove electrode supporter and a UV pre-ionizing structure are investigated aided by a high sensitivity fiber-bundle array detector, a UV fiber detector, and a framing camera, in addition to standard electrical diagnostics. The fiber-bundle-array detector is used to track the turn-on sequence of each electrode gap at a timing precision of 0.6 ns. Each fiber bundle, including five fibers with different azimuth angles, aims at the whole emitting area of each electrode gap and is fed to a photomultiplier tube. The UV fiber detector with a spectrum response of 260-320 nm, including a fused-quartz fiber of 200 μm in diameter and a solar-blinded photomultiplier tube, is adopted to study the effect of UV pre-ionizing on trigger characteristics. The framing camera, with a capacity of 4 frames per shot and an exposure time of 5 ns, is employed to capture the evolution of channel arcs. Based on the turn-on light signal of each electrode gap, the breakdown delay is divided into statistical delay and formative delay. A decrease in both of them, a smaller switch jitter and more channel arcs are observed with lower gas pressure. An increase in trigger voltage can reduce the statistical delay and its jitter, while higher trigger voltage has a relatively small influence on the formative delay and the number of channel arcs. With the UV pre-ionizing structure at 0.24 MPa gas pressure and 60 kV trigger voltage, the statistical delay and its jitter can be reduced by 1.8 ns and 0.67 ns, while the formative delay and its jitter can only be reduced by 0.5 ns and 0.25 ns.

  1. UV scale calibration transfer from an improved pyroelectric detector standard to field UV-A meters and 365 nm excitation sources

    NASA Astrophysics Data System (ADS)

    Eppeldauer, G. P.; Podobedov, V. B.; Cooksey, C. C.

    2017-05-01

    Calibration of the emitted radiation from UV sources peaking at 365 nm, is necessary to perform the ASTM required 1 mW/cm2 minimum irradiance in certain military material (ships, airplanes etc) tests. These UV "black lights" are applied for crack-recognition using fluorescent liquid penetrant inspection. At present, these nondestructive tests are performed using Hg-lamps. Lack of a proper standard and the different spectral responsivities of the available UV meters cause significant measurement errors even if the same UV-365 source is measured. A pyroelectric radiometer standard with spectrally flat (constant) response in the UV-VIS range has been developed to solve the problem. The response curve of this standard determined from spectral reflectance measurement, is converted into spectral irradiance responsivity with <0.5% (k=2) uncertainty as a result of using an absolute tie point from a Si-trap detector traceable to the primary standard cryogenic radiometer. The flat pyroelectric radiometer standard can be used to perform uniform integrated irradiance measurements from all kinds of UV sources (with different peaks and distributions) without using any source standard. Using this broadband calibration method, yearly spectral calibrations for the reference UV (LED) sources and irradiance meters is not needed. Field UV sources and meters can be calibrated against the pyroelectric radiometer standard for broadband (integrated) irradiance and integrated responsivity. Using the broadband measurement procedure, the UV measurements give uniform results with significantly decreased uncertainties.

  2. [Determination of the distribution of relative molecular mass of organic matter by high pressure size exclusion chromatography with UV and TOC detectors].

    PubMed

    Zhang, Han; Dong, Bing-Zhi

    2012-09-01

    An on-line high pressure size exclusion chromatography (HPSEC) with UV and TOC detectors was adapted to examine the distribution of relative molecular mass of natural organic matter (NOM). Through synchronous determination of UV254 and TOC responses in a wide range of relative molecular mass, it was possible to accurately characterize the structure of NOM, especially for some non-aromatic and non-conjugated double bond organics which have low response to UV. It was found that, TOC detector was capable of detecting all kinds of organic matters, including sucrose, sodium alginate and other hydrophilic organic compounds. The sample volume had a positively linear correlation with the TOC response, indicating that the larger volume would produce stronger responses. The effect of ion strength was relatively low, shown by the small decrease of peak area (1.2% ) from none to 0.2 mol x L(-1) NaCl. The pH value of tested samples should be adjusted to neutral or acidic because when the samples were alkaline, the results might be inaccurate. Compared to the sample solvents adopted as ultrapure water, the samples prepared by mobile phase solvents had less interference to salt boundary peak. The on-line HPSEC-UV-TOC can be used accurately to characterize the distribution of relative molecular mass and its four fractions in River Xiang.

  3. Analytical Stability-Indicating Methods for Alogliptin in Tablets by LC-CAD and LC-UV.

    PubMed

    Bertol, Charise Dallazem; Friedrich, Maria Tereza; Carlos, Graciela; Froehlich, Pedro Eduardo

    2017-03-01

    Stability-indicating LC methods using a UV detector and a charged aerosol detector (CAD) simultaneously were validated for the assessment of alogliptin (ALG) in tablets. The analysis was performed on a C8 column (250 × 4.6 mm, 5 μm) at a flow of 0.8 mL/min, using acetonitrile-10 mM ammonium acetate buffer (pH 3.5; 90 + 10, v/v) as mobile phase and UV detection at 275 nm. Validation followed the International Conference on Harmonization guidelines. The method was linear over the range of 25-200 μg/mL. Normality of the residuals showed a normal distribution, no autocorrelation, and homoscedasticity. LODs were 6.25 and 2.65 µg/mL and LOQs were 20.85 and 8.84 µg/mL for the CAD and the UV detector, respectively. The methods were precise and accurate. Excipients and degradation products did not interfere in the methods in studies of specificity. None of the factors studied in the analysis of robustness had a significant effect on the quantification of the ALG by the Pareto chart. The results of the assay obtained with LC-CAD and LC-UV were similar. The methods could be considered interchangeable and stability-indicating, and can be applied as an appropriate QC tool for analysis of ALG in tablets.

  4. Monitoring the High-Energy Radiation Environment of Exoplanets around Lowmass Stars with SPARCS (Star-Planet Activity Research CubeSat)

    NASA Astrophysics Data System (ADS)

    Shkolnik, Evgenya

    Seventy-five billion M dwarfs in our galaxy host at least one small planet in the habitable zone (HZ). The stellar ultraviolet (UV) radiation from M dwarfs is strong and highly variable, and impacts planetary atmospheric loss, composition and habitability. These effects are amplified by the extreme proximity of their HZs (0.1–0.4 AU). JWST will characterize HZ M dwarf planets and attempt the first spectroscopic search for life beyond the Solar System. Knowing the UV environments of M dwarf planets will be crucial to understanding their atmospheric composition and a key parameter in discriminating between biological and abiotic sources for observed biosignatures. The UV flux emitted during the super-luminous premain sequence phase of M stars drives water loss and photochemical O2 buildup for terrestrial planets within the HZ. This phase can persist for up to a billion years for the lowest mass M stars. Afterwards, UV-driven photochemistry during the main sequence phase strongly affects a planet’s atmosphere, could limit the planet’s potential for habitability, and may confuse studies of habitability by creating false chemical biosignatures. Our proposed CubeSat observatory will be the first mission to provide the time-dependent spectral slope, intensity and evolution of M dwarf stellar UV radiation. These measurements are crucial to interpreting observations of planetary atmospheres around low-mass stars. Mission: The Star-Planet Activity Research CubeSat (SPARCS) will be a 6U CubeSat devoted to monitoring 25 M stars in two UV bands: SPARCS far-UV (S- FUV: 153–171 nm) and SPARCS near-UV (S-NUV: 260– 300 nm). For each target, SPARCS will observe continuously between one and three complete stellar rotations (4–45 days) over a mission lifetime of 2 years. A UV characterization survey of M dwarfs, the most common of planet hosts, is a perfect experiment for a CubeSat: - UV astronomy cannot be done from the ground because of Earth’s atmospheric absorption. - Photometry of nearby sources is an efficient use of a small aperture. - Unlike the HST, whose time is shared among many instruments and programs, a CubeSat can provide dedicated space-based long-term monitoring in the UV. Technology: SPARCS will advance UV detector technology by flying high quantum efficiency (QE), UV-optimized detectors developed at JPL. These “delta-doped” detectors have a long history of deployment demonstrating greater than 5x the sensitivity of the detectors used by GALEX. SPARCS will pave the way for their application in missions like LUVOIR or HabEx. Education: The SPARCS research program will train future scientists and mission leaders by mentoring five undergraduate students, three graduate students, and two post-doctoral scholars throughout all aspects of the mission, including engineering, science, data management and outreach. Relevance to NASA: The SPARCS mission will address NASA’s goals of identifying the characteristics and distribution of potentially habitable environments, including HZ planet hosts like Proxima and TRAPPIST-1. SPARCS will also be capable of ‘targetofopportunity’ UV observations of NASA’s TESS yield of rocky planets in M dwarf HZs, some of the first HZ planets to be spectroscopically characterized by JWST. SPARCS can provide the needed UV context for the interpretation of transmission and emission spectra of these potentially habitable planets. Further into the future, SPARCS results will inform the target strategy for the enormous telescopic investments in exoplanet science of LUVOIR or HabEx. SPARCS’ technology will fill a gap in NASA’s capabilities to observe low-mass stellar/planetary systems in the FUV and NUV. HST’s UV capabilities will not last much later than 2019, with future opportunities (e.g., LUVOIR) not arriving until sometime after 2035. The detector technology of this CubeSat will play a crucial role in these and interim UV-capable missions.

  5. Development of a method for the characterization and operation of UV-LED for water treatment.

    PubMed

    Kheyrandish, Ataollah; Mohseni, Madjid; Taghipour, Fariborz

    2017-10-01

    Tremendous improvements in semiconductor technology have made ultraviolet light-emitting diodes (UV-LEDs) a viable alternative to conventional UV sources for water treatment. A robust and validated experimental protocol for studying the kinetics of microorganism inactivation is key to the further development of UV-LEDs for water treatment. This study proposes a protocol to operate UV-LEDs and control their output as a polychromatic radiation source. In order to systematically develop this protocol, the results of spectral power distribution, radiation profile, and radiant power measurements of a variety of UV-LEDs are presented. A wide range of UV-LEDs was selected for this study, covering various UVA, UVB, and UVC wavelengths, viewing angles from 3.5° to 135°, and a variety of output powers. The effects of operational conditions and measurement techniques were investigated on these UV-LEDs using a specially designed and fabricated setup. Operating conditions, such as the UV-LED electrical current and solder temperature, were found to significantly affect the power and peak wavelength output. The measurement techniques and equipment, including the detector size, detector distance from the UV-LED, and potential reflection from the environment, were shown to influence the results for many of the UV-LEDs. The results obtained from these studies were analyzed and applied to the development of a protocol for UV-LED characterization. This protocol is presented as a guideline that allows the operation and control of UV-LEDs in any structure, as well as accurately measuring the UV-LED output. Such information is essential for performing a reliable UV-LED assessment for the inactivation of microorganisms and for obtaining precise kinetic data. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. The system of high accuracy UV spectral radiation system

    NASA Astrophysics Data System (ADS)

    Lin, Guan-yu; Yu, Lei; Xu, Dian; Cao, Dian-sheng; Yu, Yu-Xiang

    2016-10-01

    UV spectral radiation detecting and visible observation telescope is designed by the coaxial optical. In order to decrease due to the incident light polarization effect, and improve the detection precision, polarizer need to be used in the light path. Four pieces of quartz of high Precision UV radiation depolarizer retarder stack together is placed in front of Seya namioka dispersion unit. The coherent detection principle of modulation of light signal and the reference signal multiplied processing, increase the phase sensitive detector can be adjustment function, ensure the UV spectral radiation detection stability. A lock-in amplifier is used in the electrical system to advance the accuracy of measurement. To ensure the precision measurement detected, the phase-sensitive detector function can be adjustable. the output value is not more than 10mV before each measurement, so it can be ensured that the stability of the measured radiation spectrum is less than 1 percent.

  7. Laser induced fluorescence of biochemical for UV LIDAR application.

    PubMed

    Gupta, L; Sharma, R C; Razdan, A K; Maini, A K

    2014-05-01

    Laser induced fluorescence spectroscopy in the ultraviolet regime has been used for the detection of biochemical through a fiber coupled CCD detector from a distance of 2 m. The effect of concentration and laser excitation energy on the fluorescence spectra of nicotinamide adenine dinucleotide (NADH) has been investigated. The signature fluorescence peak of NADH was centred about 460 nm. At lower concentration Raman peak centred at 405 nm was also observed. The origin of this peak has been discussed. Detection limit with the proposed set up is found to be 1 ppm.

  8. Design and fabrication of a window for the gas Cherenkov detector 3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fatherley, V. E., E-mail: vef@lanl.gov; Bingham, D. A.; Cartelli, M. D.

    2016-11-15

    The gas Cherenkov detector 3 was designed at Los Alamos National Laboratory for use in inertial confinement fusion experiments at both the Omega Laser Facility and the National Ignition Facility. This instrument uses a low-Z gamma-to-electron convertor plate and high pressure gas to convert MeV gammas into UV/visible Cherenkov photons for fast optical detection. This is a follow-on diagnostic from previous versions, with two notable differences: the pressure of the gas is four times higher, and it allows the use of fluorinated gas, requiring metal seals. These changes force significant changes in the window component, having a unique set ofmore » requirements and footprint limitations. The selected solution for this component, a sapphire window brazed into a stainless steel flange housing, is described.« less

  9. Design and fabrication of a window for the Gas Cherenkov Detector 3

    DOE PAGES

    Fatherley, Valerie E.; Bingham, David A.; Cartelli, Myles Derrick; ...

    2016-08-23

    The gas Cherenkov detector 3 was designed at Los Alamos National Laboratory for use in inertial confinement fusion experiments at both the Omega Laser Facility and the National Ignition Facility. This instrument uses a low-Z gamma-to-electron convertor plate and high pressure gas to convert MeV gammas into UV/visible Cherenkov photons for fast optical detection. This is a follow-on diagnostic from previous versions, with two notable differences: the pressure of the gas is four times higher, and it allows the use of fluorinated gas, requiring metal seals. These changes force significant changes in the window component, having a unique set ofmore » requirements and footprint limitations. Finally, the selected solution for this component, a sapphire window brazed into a stainless steel flange housing, is described.« less

  10. Autonomous long-range open area fire detection and reporting

    NASA Astrophysics Data System (ADS)

    Engelhaupt, Darell E.; Reardon, Patrick J.; Blackwell, Lisa; Warden, Lance; Ramsey, Brian D.

    2005-03-01

    Approximately 5 billion dollars in US revenue was lost in 2003 due to open area fires. In addition many lives are lost annually. Early detection of open area fires is typically performed by manned observatories, random reporting and aerial surveillance. Optical IR flame detectors have been developed previously. They typically have experienced high false alarms and low flame detection sensitivity due to interference from solar and other causes. Recently a combination of IR detectors has been used in a two or three color mode to reduce false alarms from solar, or background sources. A combination of ultra-violet C (UVC) and near infra-red (NIR) detectors has also been developed recently for flame discrimination. Relatively solar-blind basic detectors are now available but typically detect at only a few tens of meters at ~ 1 square meter fuel flame. We quantify the range and solar issues for IR and visible detectors and qualitatively define UV sensor requirements in terms of the mode of operation, collection area issues and flame signal output by combustion photochemistry. We describe innovative flame signal collection optics for multiple wavelengths using UV and IR as low false alarm detection of open area fires at long range (8-10 km/m2) in daylight (or darkness). A circular array detector and UV-IR reflective and refractive devices including cylindrical or toroidal lens elements for the IR are described. The dispersion in a refractive cylindrical IR lens characterizes the fire and allows a stationary line or circle generator to locate the direction and different flame IR "colors" from a wide FOV. The line generator will produce spots along the line corresponding to the fire which can be discriminated with a linear detector. We demonstrate prototype autonomous sensors with RF digital reporting from various sites.

  11. Flame Detector

    NASA Technical Reports Server (NTRS)

    1990-01-01

    Scientific Instruments, Inc. has now developed a second generation, commercially available instrument to detect flames in hazardous environments, typically refineries, chemical plants and offshore drilling platforms. The Model 74000 detector incorporates a sensing circuit that detects UV radiation in a 100 degree conical field of view extending as far as 250 feet from the instrument. It operates in a bandwidth that makes it virtually 'blind' to solar radiation while affording extremely high sensitivity to ultraviolet flame detection. A 'windowing' technique accurately discriminates between background UV radiation and ultraviolet emitted from an actual flame, hence the user is assured of no false alarms. Model 7410CP is a combination controller and annunciator panel designed to monitor and control as many as 24 flame detectors. *Model 74000 is no longer being manufactured.

  12. Evaluation of large format electron bombarded virtual phase CCDs as ultraviolet imaging detectors

    NASA Technical Reports Server (NTRS)

    Opal, Chet B.; Carruthers, George R.

    1989-01-01

    In conjunction with an external UV-sensitive cathode, an electron-bombarded CCD may be used as a high quantum efficiency/wide dynamic range photon-counting UV detector. Results are presented for the case of a 1024 x 1024, 18-micron square pixel virtual phase CCD used with an electromagnetically focused f/2 Schmidt camera, which yields excellent simgle-photoevent discrimination and counting efficiency. Attention is given to the vacuum-chamber arrangement used to conduct system tests and the CCD electronics and data-acquisition systems employed.

  13. Microgap ultra-violet detector

    DOEpatents

    Wuest, Craig R.; Bionta, Richard M.

    1994-01-01

    A microgap ultra-violet detector of photons with wavelengths less than 400 run (4000 Angstroms) which comprises an anode and a cathode separated by a gas-filled gap and having an electric field placed across the gap. Either the anode or the cathode is semi-transparent to UV light. Upon a UV photon striking the cathode an electron is expelled and accelerated across the gap by the electric field causing interactions with other electrons to create an electron avalanche which contacts the anode. The electron avalanche is detected and converted to an output pulse.

  14. Large-Format AlGaN PIN Photodiode Arrays for UV Images

    NASA Technical Reports Server (NTRS)

    Aslam, Shahid; Franz, David

    2010-01-01

    A large-format hybridized AlGaN photodiode array with an adjustable bandwidth features stray-light control, ultralow dark-current noise to reduce cooling requirements, and much higher radiation tolerance than previous technologies. This technology reduces the size, mass, power, and cost of future ultraviolet (UV) detection instruments by using lightweight, low-voltage AlGaN detectors in a hybrid detector/multiplexer configuration. The solar-blind feature eliminates the need for additional visible light rejection and reduces the sensitivity of the system to stray light that can contaminate observations.

  15. Microgap ultra-violet detector

    DOEpatents

    Wuest, C.R.; Bionta, R.M.

    1994-09-20

    A microgap ultra-violet detector of photons with wavelengths less than 400 run (4,000 Angstroms) which comprises an anode and a cathode separated by a gas-filled gap and having an electric field placed across the gap is disclosed. Either the anode or the cathode is semi-transparent to UV light. Upon a UV photon striking the cathode an electron is expelled and accelerated across the gap by the electric field causing interactions with other electrons to create an electron avalanche which contacts the anode. The electron avalanche is detected and converted to an output pulse. 2 figs.

  16. Bias-switchable negative and positive photoconductivity in 2D FePS3 ultraviolet photodetectors.

    PubMed

    Gao, Yi; Lei, Shuijin; Kang, Tingting; Fei, Linfeng; Mak, Chee-Leung; Yuan, Jian; Zhang, Mingguang; Li, Shaojuan; Bao, Qiaoliang; Zeng, Zhongming; Wang, Zhao; Gu, Haoshuang; Zhang, Kai

    2018-06-15

    Metal-phosphorus-trichalcogenides (MPTs), represented by NiPS 3 , FePS 3 , etc, are newly developed 2D wide-bandgap semiconductors and have been proposed as excellent candidates for ultraviolet (UV) optoelectronics. In spite of having superior advantages for solar-blind UV photodetectors, including those free of surface trap states, being highly compatible with versatile integrations as well as having an appropriate band gap, to date relevant study is rare. In this work, the photoresponse characteristic of UV detectors based on few-layer FePS 3 has been comprehensively investigated. The responsivity of the photodetector, which is observed to be determined by bias gate voltage, may achieve as high as 171.6 mAW -1 under the illumination of 254 nm weak light, which is comparable to most commercial UV detectors. Notably, both negative and positive photoconductivities exist in the FePS 3 photodetectors and can be controllably switched with bias voltage. The eminent and novel photoresponse property paves the way for the further development and practical use of 2D MPTs in high-performance UV photodetections.

  17. Bias-switchable negative and positive photoconductivity in 2D FePS3 ultraviolet photodetectors

    NASA Astrophysics Data System (ADS)

    Gao, Yi; Lei, Shuijin; Kang, Tingting; Fei, Linfeng; Mak, Chee-Leung; Yuan, Jian; Zhang, Mingguang; Li, Shaojuan; Bao, Qiaoliang; Zeng, Zhongming; Wang, Zhao; Gu, Haoshuang; Zhang, Kai

    2018-06-01

    Metal-phosphorus-trichalcogenides (MPTs), represented by NiPS3, FePS3, etc, are newly developed 2D wide-bandgap semiconductors and have been proposed as excellent candidates for ultraviolet (UV) optoelectronics. In spite of having superior advantages for solar-blind UV photodetectors, including those free of surface trap states, being highly compatible with versatile integrations as well as having an appropriate band gap, to date relevant study is rare. In this work, the photoresponse characteristic of UV detectors based on few-layer FePS3 has been comprehensively investigated. The responsivity of the photodetector, which is observed to be determined by bias gate voltage, may achieve as high as 171.6 mAW‑1 under the illumination of 254 nm weak light, which is comparable to most commercial UV detectors. Notably, both negative and positive photoconductivities exist in the FePS3 photodetectors and can be controllably switched with bias voltage. The eminent and novel photoresponse property paves the way for the further development and practical use of 2D MPTs in high-performance UV photodetections.

  18. Visible-blind ultraviolet photodetectors on porous silicon carbide substrates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Naderi, N.; Hashim, M.R., E-mail: roslan@usm.my

    2013-06-01

    Highlights: • Highly reliable UV detectors are fabricated on porous silicon carbide substrates. • The optical properties of samples are enhanced by increasing the current density. • The optimized sample exhibits enhanced sensitivity to the incident UV radiation. - Abstract: Highly reliable visible-blind ultraviolet (UV) photodetectors were successfully fabricated on porous silicon carbide (PSC) substrates. High responsivity and high photoconductive gain were observed in a metal–semiconductor–metal ultraviolet photodetector that was fabricated on an optimized PSC substrate. The PSC samples were prepared via the UV-assisted photo-electrochemical etching of an n-type hexagonal silicon carbide (6H-SiC) substrate using different etching current densities. Themore » optical results showed that the current density is an outstanding etching parameter that controls the porosity and uniformity of PSC substrates. A highly porous substrate was synthesized using a suitable etching current density to enhance its light absorption, thereby improving the sensitivity of UV detector with this substrate. The electrical characteristics of fabricated devices on optimized PSC substrates exhibited enhanced sensitivity and responsivity to the incident radiation.« less

  19. Report of the ultraviolet and visible sensors panel

    NASA Technical Reports Server (NTRS)

    Timothy, J. Gethyn; Blouke, M.; Bredthauer, R.; Kimble, R.; Lee, T.-H.; Lesser, M.; Siegmund, O.; Weckler, G.

    1991-01-01

    In order to meet the science objectives of the Astrotech 21 mission set the Ultraviolet (UV) and Visible Sensors Panel made a number of recommendations. In the UV wavelength range of 0.01 to 0.3 micro-m the focus is on the need for large format high quantum efficiency, radiation hard 'solar-blind' detectors. Options recommended for support include Si and non-Si charge coupled devices (CCDs) as well as photocathodes with improved microchannel plate readouts. For the 0.3 to 0.9 micro-m range, it was felt that Si CCDs offer the best option for high quantum efficiencies at these wavelengths. In the 0.9 to 2.5 micro-m the panel recommended support for the investigation of monolithic arrays. Finally, the panel noted that the implementation of very large arrays will require new data transmission, data recording, and data handling technologies.

  20. UV Detector Materials Development Program

    DTIC Science & Technology

    1981-12-01

    document. UNCLASSIFIED SECURITY CLASSIFICATION OF THIr odkE ’Whe Date Entered) READ INSTRUCTIONS REPORT DOCUMENTATION PAGE BEFORE COMPLETING FORM 1... collection efficiency within the detector (internal quantum efficiency). As mentioned previously, it was found that reverse biasing the Schottky diodes...the ratio of the number of carriers collected in the detector versus the number of photons entering into the absorbing region. It is, therefore

  1. Single Lab Validation of a LC/UV/FLD/MS Method for Simultaneous Determination of Water-soluble Vitamins in Multi-Vitamin Dietary Supplements

    USDA-ARS?s Scientific Manuscript database

    The purpose of this study was to develop a Single-Lab Validated Method using high-performance liquid chromatography (HPLC) with different detectors (diode array detector - DAD, fluorescence detector - FLD, and mass spectrometer - MS) for determination of seven B-complex vitamins (B1 - thiamin, B2 – ...

  2. Sensitive far uv spectrograph with a multispectral element microchannel plate detector for rocket-borne astronomy.

    PubMed

    Weiser, H; Vitz, R C; Moos, H W; Weinstein, A

    1976-12-01

    An evacuated high transmission prism spectrograph using a microchannel plate detection system with resistive strip readout was flown behind a precision pointing telescope on a sounding rocket. The construction, preparation, flight performance, and calibration stability of the system are discussed. Despite the adverse environmental conditions associated with sounding rocket flights, the microchannel detector system performed well. Far uv spectra (1160-1750 A) of stellar and planetary objects were obtained; spectral features with fluxes as low as 0.06 photons cm(-2) sec(-1) were detectable. This was achieved by operating the plates at lower than normal gains, using sensitive pulse counting electronics with both upper and lower limit discriminators, and maintaining the spectrograph and detector at a pressure of ~10(-6) Torr until reaching altitude.

  3. High performance liquid chromatography used for quality control of Achyranthis Radix.

    PubMed

    Zhao, Bing Tian; Jeong, Su Yang; Moon, Dong Cheul; Son, Kun Ho; Son, Jong Keun; Woo, Mi Hee

    2012-08-01

    To establish a standard of quality control and to identify reliable Achyranthis Radix, three phytoecdysones including ecdysterone (1), 25R-inokosterone (2) and 25S-inokosterone (3) were determined by quantitative HPLC/UV analysis. Three phytoecdysones were separated with an YMC J'sphere ODS C(18) column (250 mm × 4.6 mm, 4 μm) by isocratic elution using 0.1% formic acid in water and acetonitrile (85:15, v/v%) as the mobile phase. The flow rate was 1.0 mL/min and the UV detector wavelength was set at 245 nm. The standards were quantified by HPLC/UV from Achyranthes bidentata Blume and Achyranthes japonica Nakai, as well as Cyathula capitata Moq. and Cyathula officinalis Kuan, which are of a different genus but are comparative herbs. The method was successfully used in the analysis of Achyranthis Radix of different geographical origin or genera with relatively simple conditions and procedures, and the assay results were satisfactory for linearity, recovery, precision, accuracy, stability and robustness. The HPLC analytical method for pattern recognition analysis was validated by repeated analysis of eighteen A. bidentata Blume samples and ten A. japonica Nakai samples. The results indicate that the established HPLC/UV method is suitable for quantitation and pattern recognition analyses for quality evaluation of Achyranthis Radix.

  4. High-Performance Visible-Blind UV Phototransistors Based on n-Type Naphthalene Diimide Nanomaterials.

    PubMed

    Song, Inho; Lee, Seung-Chul; Shang, Xiaobo; Ahn, Jaeyong; Jung, Hoon-Joo; Jeong, Chan-Uk; Kim, Sang-Wook; Yoon, Woojin; Yun, Hoseop; Kwon, O-Pil; Oh, Joon Hak

    2018-04-11

    This study investigates the performance of single-crystalline nanomaterials of wide-band gap naphthalene diimide (NDI) derivatives with methylene-bridged aromatic side chains. Such materials are found to be easily used as high-performance, visible-blind near-UV light detectors. NDI single-crystalline nanoribbons are assembled using a simple solution-based process (without solvent-inclusion problems), which is then applied to organic phototransistors (OPTs). Such OPTs exhibit excellent n-channel transistor characteristics, including an average electron mobility of 1.7 cm 2 V -1 s -1 , sensitive UV detection properties with a detection limit of ∼1 μW cm -2 , millisecond-level responses, and detectivity as high as 10 15 Jones, demonstrating the highly sensitive organic visible-blind UV detectors. The high performance of our OPTs originates from the large face-to-face π-π stacking area between the NDI semiconducting cores, which is facilitated by methylene-bridged aromatic side chains. Interestingly, NDI-based nanoribbon OPTs exhibit a distinct visible-blind near-UV detection with an identical detection limit, even under intense visible light illumination (for example, 10 4 times higher intensity than UV light intensity). Our findings demonstrate that wide-band gap NDI-based nanomaterials are highly promising for developing high-performance visible-blind UV photodetectors. Such photodetectors could potentially be used for various applications including environmental and health-monitoring systems.

  5. Experimental Evaluation of Turbidity Impact on the Fluence Rate Distribution in a UV Reactor Using a Microfluorescent Silica Detector.

    PubMed

    Li, Mengkai; Li, Wentao; Wen, Dong; Qiang, Zhimin; Blatchley, Ernest R

    2017-11-21

    Turbidity is a common parameter used to assess particle concentration in water using visible light. However, the fact that particles play multiple roles (e.g., scattering, refraction, and reflection) in influencing the optical properties of aqueous suspensions complicates examinations of their effects on ultraviolet (UV) photoreactor performance. To address this issue, UV fluence rate (FR) distributions in a photoreactor containing various particle suspensions (SiO 2 , MgO, and TiO 2 ) were measured using a microfluorescent silica detector (MFSD). Reflectance of solid particles, as well as transmittance and scattering properties of the suspensions were characterized at UV, visible, and infrared (IR) wavelengths. The results of these measurements indicated that the optical properties of all three particle types were similar at visible and IR wavelengths, but obvious differences were evident in the UV range. The FR results indicated that for turbidity associated with SiO 2 and MgO suspensions, the weighted average FR (WAFR) increased relative to deionized water. These increases were attributed to low particle photon absorption and strong scattering. In contrast, the WAFR values decreased with increasing turbidity for TiO 2 suspensions because of their high particle photon absorption and low scattering potential. The findings also indicate that measurements of scattering and transmittance at UV wavelengths can be used to quantify the effects of turbidity on UV FR distributions.

  6. New technologies for UV detectors

    NASA Technical Reports Server (NTRS)

    Joseph, C. L.

    1993-01-01

    Several technologies are currently being developed, leading to substantial improvements in the performance of UV detectors or significant reductions in power or weight. Four technologies discussed are (1) thin-film coatings to enhance the UV sensitivity of CCD's, (2) highly innovative magnet assemblies that dramatically reduce weight and result in virtually no external flux, (3) new techniques for curving microchannel plates (MCP's) so that single plates can be used to prevent ion feedback and present highly localized charge clouds to an anode structure, and (4) high-performance alternatives to glass-based MCP's. In item (2), for example, very robust magnets are made out of rare earth materials such as samarium cobalt, and cladding magnets are employed to prevent flux from escaping from the detector into the external environment. These new ultralight magnet assemblies are able to create strong, exceptionally uniform magnetic fields for image intensification and focusing of photoelectrons. The principle advantage of such detectors is the quantum efficiencies of 70-80 percent obtained throughout ultraviolet wavelengths (900-2000 A), the highest of any device. Despite the improvements achieved under item (3), high-performance alternatives to conventional glass-based MCP's potentially offer three distinct new advantages that include (1) a 30-100-fold improvement in dynamic range resulting in correspondingly higher signal-to-noise ratios, (2) the use of pure dielectric and semiconductor materials that will not outgas contaminants that eventually destroy photocathodes, and (3) channels that have constant spacing providing long-ranged order since the plates are made using photolithography techniques from the semiconductor industry. The manufacturers of these advanced-technology MCP's, however, are a couple of years away from actually producing a functioning image intensifier. In contrast to the use of CCD's for optical, ground based observations, there is no single detector technology in the ultraviolet that dominates or is as universally suitable for all applications. Thus, several technological problems, recent advances, and the impact that these new enabling technologies represent for UV applications are addressed.

  7. The PUR Experiment on the EXPOSE-R facility: biological dosimetry of solar extraterrestrial UV radiation

    NASA Astrophysics Data System (ADS)

    Bérces, A.; Egyeki, M.; Fekete, A.; Horneck, G.; Kovács, G.; Panitz, C.

    2015-01-01

    The aim of our experiment Phage and Uracil Response was to extend the use of bacteriophage T7 and uracil biological dosimeters for measuring the biologically effective ultraviolet (UV) dose in the harsh extraterrestrial radiation conditions. The biological detectors were exposed in vacuum-tightly cases in the European Space Agency (ESA) astrobiological exposure facility attached to the external platform of Zvezda (EXPOSE-R). EXPOSE-R took off to the International Space Station (ISS) in November 2008 and was installed on the External platform of the Russian module Zvezda of the ISS in March 2009. Our goal was to determine the dose-effect relation for the formation of photoproducts (i.e. damage to phage DNA and uracil, respectively). The extraterrestrial solar UV radiation ranges over the whole spectrum from vacuum-UV (λ<200 nm) to UVA (315 nm<λ<400 nm), which causes photolesions (photoproducts) in the nucleic acids/their components either by photoionization or excitation. However, these wavelengths cause not only photolesions but in a wavelength-dependent efficiency the reversion of some photolesions, too. Our biological detectors measured in situ conditions the resultant of both reactions induced by the extraterrestrial UV radiation. From this aspect the role of the photoreversion in the extension of the biological UV dosimetry are discussed.

  8. Modelling ultraviolet threats

    NASA Astrophysics Data System (ADS)

    James, I.

    2016-10-01

    Electro-optically (EO) guided surface to air missiles (SAM) have developed to use Ultraviolet (UV) wavebands supplementary to the more common Infrared (IR) wavebands. Missiles such as the US Stinger have been around for some time but are not considered a proliferation risk. The Chinese FN-16 and Russian SA-29 (Verba) are considered a much higher proliferation risk. As a result, models of the missile seekers must be developed to understand the characteristics of the seeker and the potential performance enhancement that are included. Therefore, the purpose of this paper is to introduce the steps that have been taken to characterise and model these missiles. It begins by outlining some of the characteristics of the threats, the key elements of a UV scene, the potential choice of waveband for a detector, the initial modelling work to represent the UV detector of the missile and presents initial results. The modelling shows that the UV detection range of a typical aircraft is dependent on both the size of the aircraft and its reflectivity. However, the strength of this correlation is less than expected. As a result, further work is required to model more seeker types and to investigate what is causing the weak correlations found in these initial investigations. In addition, there needs to be further study of the sensitivities of the model to other variables, such as the modelled detectivity of the detector and the signal to noise ratio assumed. Overall, the outcome of this work will be to provide specifications for aircraft size and reflectivity that limit the effectiveness of the UV channels.

  9. Surface/Interface Carrier-Transport Modulation for Constructing Photon-Alternative Ultraviolet Detectors Based on Self-Bending-Assembled ZnO Nanowires.

    PubMed

    Guo, Zhen; Zhou, Lianqun; Tang, Yuguo; Li, Lin; Zhang, Zhiqi; Yang, Hongbo; Ma, Hanbin; Nathan, Arokia; Zhao, Dongxu

    2017-09-13

    Surface/interface charge-carrier generation, diffusion, and recombination/transport modulation are especially important in the construction of photodetectors with high efficiency in the field of nanoscience. In the paper, a kind of ultraviolet (UV) detector is designed based on ZnO nanostructures considering photon-trapping, surface plasmonic resonance (SPR), piezophototronic effects, interface carrier-trapping/transport control, and collection. Through carefully optimized surface/interface carrier-transport modulation, a designed device with detectivity as high as 1.69 × 10 16 /1.71 × 10 16 cm·Hz 1/2 /W irradiating with 380 nm photons under ultralow bias of 0.2 V is realized by alternating nanoparticle/nanowire active layers, respectively, and the designed UV photodetectors show fast and slow recovery processes of 0.27 and 4.52 ms, respectively, which well-satisfy practical needs. Further, it is observed that UV photodetection could be performed within an alternative response by varying correlated key parameters, through efficient surface/interface carrier-transport modulation, spectrally resolved photoresponse of the detector revealing controlled detection in the UV region based on the ZnO nanomaterial, photodetection allowed or limited by varying the active layers, irradiation distance from one of the electrodes, standing states, or electric field. The detailed carrier generation, diffusion, and recombination/transport processes are well illustrated to explain charge-carrier dynamics contributing to the photoresponse behavior.

  10. UV-visible-DAD and 1H-NMR spectroscopy data fusion for studying the photodegradation process of azo-dyes using MCR-ALS.

    PubMed

    Fernández, Cristina; Pilar Callao, M; Larrechi, M Soledad

    2013-12-15

    The photodegradation process of three azo-dyes - Acid Orange 61, Acid Red 97 and Acid Brown 425 - was monitored simultaneously by ultraviolet-visible spectroscopy with diode array detector (UV-vis-DAD) and (1)H-nuclear magnetic resonance ((1)H-NMR). Multivariate curve resolution-alternating least squares (MCR-ALS) was applied to obtain the concentration and spectral profile of the chemical compounds involved in the process. The analysis of the H-NMR data suggests there are more intermediate compounds than those obtained with the UV-vis-DAD data. The fusion of UV-vis-DAD and the (1)H-NMR signal before the multivariate analysis provides better results than when only one of the two detector signals was used. It was concluded that three degradation products were present in the medium when the three azo-dyes had practically degraded. This study is the first application of UV-vis-DAD and (1)H-NMR spectroscopy data fusion in this field and illustrates its potential as a quick method for evaluating the evolution of the azo-dye photodegradation process. © 2013 Elsevier B.V. All rights reserved.

  11. Instrumentation: Photodiode Array Detectors in UV-VIS Spectroscopy. Part II.

    ERIC Educational Resources Information Center

    Jones, Dianna G.

    1985-01-01

    A previous part (Analytical Chemistry; v57 n9 p1057A) discussed the theoretical aspects of diode ultraviolet-visual (UV-VIS) spectroscopy. This part describes the applications of diode arrays in analytical chemistry, also considering spectroelectrochemistry, high performance liquid chromatography (HPLC), HPLC data processing, stopped flow, and…

  12. Performance analyses of Schottky diodes with Au/Pd contacts on n-ZnO thin films as UV detectors

    NASA Astrophysics Data System (ADS)

    Varma, Tarun; Periasamy, C.; Boolchandani, Dharmendar

    2017-12-01

    In this paper, we report fabrication and performance analyses of UV detectors based on ZnO thin film Schottky diodes with Au and Pd contacts. RF magnetron sputtering technique has been used to deposit the nano-crystalline ZnO thin film, at room temperature. Characterization techniques such as XRD, AFM and SEM provided valuable information related to the micro-structural & optical properties of the thin film. The results show that the prepared thin film has good crystalline orientation and minimal surface roughness, with an optical bandgap of 3.1 eV. I-V and C-V characteristics were evaluated that indicate non-linear behaviour of the diodes with rectification ratios (IF/IR) of 19 and 427, at ± 4 V, for Au/ZnO and Pd/ZnO Schottky diodes, respectively. The fabricated Schottky diodes when exposed to a UV light of 365 nm wavelength, at an applied bias of -2 V, exhibited responsivity of 10.16 and 22.7 A/W, for Au and Pd Schottky contacts, respectively. The Pd based Schottky photo-detectors were found to exhibit better performance with superior values of detectivity and photoconductive gain of 1.95 × 1010 cm Hz0.5/W & 77.18, over those obtained for the Au based detectors which were observed to be 1.23 × 1010 cm Hz0.5/W & 34.5, respectively.

  13. The calibration of read-out-streak photometry in the XMM-Newton Optical Monitor and the construction of a bright-source catalogue

    NASA Astrophysics Data System (ADS)

    Page, M. J.; Chan, N.; Breeveld, A. A.; Talavera, A.; Yershov, V.; Kennedy, T.; Kuin, N. P. M.; Hancock, B.; Smith, P. J.; Carter, M.

    2017-04-01

    The dynamic range of the XMM-Newton Optical Monitor (XMM-OM) is limited at the bright end by coincidence loss, the superposition of multiple photons in the individual frames recorded from its micro-channel-plate (MCP) intensified charge-coupled device (CCD) detector. One way to overcome this limitation is to use photons that arrive during the frame transfer of the CCD, forming vertical read-out streaks for bright sources. We calibrate these read-out streaks for photometry of bright sources observed with XMM-OM. The bright-source limit for read-out-streak photometry is set by the recharge time of the MCPs. For XMM-OM, we find that the MCP recharge time is 5.5 × 10-4 s. We determine that the effective bright limits for read-out-streak photometry with XMM-OM are approximately 1.5 mag brighter than the bright-source limits for normal aperture photometry in full-frame images. This translates into bright-source limits in Vega magnitudes of UVW2=7.1, UVM2=8.0, UVW1=9.4, U=10.5, B=11.5, V=10.2, and White=12.5 for data taken early in the mission. The limits brighten by up to 0.2 mag, depending on filter, over the course of the mission as the detector ages. The method is demonstrated by deriving UVW1 photometry for the symbiotic nova RR Telescopii, and the new photometry is used to constrain the e-folding time of its decaying ultraviolet (UV) emission. Using the read-out-streak method, we obtain photometry for 50 per cent of the missing UV source measurements in version 2.1 of the XMM-Newton Serendipitous UV Source Survey catalogue.

  14. Development of a Bioaerosol single particle detector (BIO IN) for the Fast Ice Nucleus CHamber FINCH

    NASA Astrophysics Data System (ADS)

    Bundke, U.; Reimann, B.; Nillius, B.; Jaenicke, R.; Bingemer, H.

    2010-02-01

    In this work we present the setup and first tests of our new BIO IN detector. This detector was constructed to classify atmospheric ice nuclei (IN) for their biological content. It is designed to be coupled to the Fast Ice Nucleus CHamber FINCH. If one particle acts as an ice nucleus, it will be at least partly covered with ice at the end of the development section of the FINCH chamber. The device combines an auto-fluorescence detector and a circular depolarization detector for simultaneous detection of biological material and discrimination between water droplets, ice crystals and non activated large aerosol particles. The excitation of biological material with UV light and analysis of auto-fluorescence is a common principle used for flow cytometry, fluorescence microscopy, spectroscopy and imaging. The detection of auto-fluorescence of airborne single particles demands some more experimental effort. However, expensive commercial sensors are available for special purposes, e.g. size distribution measurements. But these sensors will not fit the specifications needed for the FINCH IN counter (e.g. high sample flow of up 10 LPM). The newly developed -low cost- BIO IN sensor uses a single high-power UV LED for the electronic excitation instead of much more expensive UV lasers. Other key advantages of the new sensor are the low weight, compact size, and the little effect on the aerosol sample, which allows it to be coupled with other instruments for further analysis. The instrument will be flown on one of the first missions of the new German research aircraft "HALO" (High Altitude and LOng range).

  15. Dual Band Deep Ultraviolet AlGaN Photodetectors

    NASA Technical Reports Server (NTRS)

    Aslam, S.; Miko, L.; Stahle, C.; Franz, D.; Pugel, D.; Guan, B.; Zhang, J. P.; Gaska, R.

    2007-01-01

    We report on the design, fabrication and characterization of a back-illuminated voltage bias selectable dual-band AlGaN UV photodetector. The photodetector can separate UVA and W-B band radiation by bias switching a two terminal n-p-n homojunction structure that is fabricated in the same pixel. When a forward bias is applied between the top and bottom electrodes, the detector can sense UV-A and reject W-B band radiation. Alternatively, under reverse bias, the photodetector can sense UV-B and reject UV-A band radiation.

  16. Efficient Ultraviolet Light Detector Based on a Crystalline Viologen-Based Metal-Organic Framework with Rapid Visible Color Change under Irradiation.

    PubMed

    Hu, Shuzhi; Zhang, Jie; Chen, Shuhuang; Dai, Jingcao; Fu, Zhiyong

    2017-11-22

    A convenient colorimetric molecular system constructed by the zinc viologen-carboxylate framework is developed for naked eye detection of instantaneous UV exposure levels. Only narrow-band absorption in UV regions and a unique interpenetrated structure of its colorless crystal enable the system to give a fast response toward UV irradiance with intensity as low as 0.001 mw/cm 2 .

  17. Rapid ultrasonic and microwave-assisted micellar extraction of zingiberone, shogaol and gingerols from gingers using biosurfactants.

    PubMed

    Peng, Li-Qing; Cao, Jun; Du, Li-Jing; Zhang, Qi-Dong; Xu, Jing-Jing; Chen, Yu-Bo; Shi, Yu-Ting; Li, Rong-Rong

    2017-09-15

    Two kinds of extraction methods ultrasonic-assisted micellar extraction (UAME) and microwave-assisted micellar extraction (MAME) coupled with ultra-high performance liquid chromatography with ultraviolet detector (UHPLC-UV) were developed and evaluated for extraction and determination of zingerone, 6-gingerol, 8-gingerol, 6-shogaol and 10-gingerol in Rhizoma Zingiberis and Rhizoma Zingiberis Preparata. A biosurfactant, hyodeoxycholic acid sodium salt, was used in micellar extraction. Several experimental parameters were studied separately by a univariate method. The result indicated that the MAME was more efficient than UAME. The optimal conditions of MAME were as follows: 100mM of hyodeoxycholic acid sodium salt was used as surfactant, the irradiation time was set at 10s and the extraction temperature was set at 60°C. The validation results indicated that the limits of detection were in the range of 3.80-8.11ng/mL. The average recoveries were in the range of 87.32-103.12% for the two samples at two spiking levels. Compared with other reported methods, the proposed MAME-UHPLC-UV method was more effective, quicker (10s) and more eco-friendly. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Atmospheric scattering of middle uv radiation from an internal source.

    PubMed

    Meier, R R; Lee, J S; Anderson, D E

    1978-10-15

    A Monte Carlo model has been developed which simulates the multiple-scattering of middle-uv radiation in the lower atmosphere. The source of radiation is assumed to be monochromatic and located at a point. The physical effects taken into account in the model are Rayleigh and Mie scattering, pure absorption by particulates and trace atmospheric gases, and ground albedo. The model output consists of the multiply scattered radiance as a function of look-angle of a detector located within the atmosphere. Several examples are discussed, and comparisons are made with direct-source and single-scattered contributions to the signal received by the detector.

  19. A radiation detector design mitigating problems related to sawed edges

    NASA Astrophysics Data System (ADS)

    Aurola, A.; Marochkin, V.; Tuuva, T.

    2014-12-01

    In pixelated silicon radiation detectors that are utilized for the detection of UV, visible, and in particular Near Infra-Red (NIR) light it is desirable to utilize a relatively thick fully depleted Back-Side Illuminated (BSI) detector design providing 100% Fill Factor (FF), low Cross-Talk (CT), and high Quantum Efficiency (QE). The optimal thickness of such detectors is typically less than 300μm and above 40μm and thus it is more or less mandatory to thin the detector wafer from the backside after the front side of the detector has been processed and before a conductive layer is formed on the backside. A TAIKO thinning process is optimal for such a thickness range since neither a support substrate on the front side nor lithographic steps on the backside are required. The conductive backside layer should, however, be homogenous throughout the wafer and it should be biased from the front side of the detector. In order to provide good QE for blue and UV light the conductive backside layer should be of opposite doping type than the substrate. The problem with a homogeneous backside layer being of opposite doping type than the substrate is that a lot of leakage current is typically generated at the sawed chip edges, which may increase the dark noise and the power consumption. These problems are substantially mitigated with a proposed detector edge arrangement which 2D simulation results are presented in this paper.

  20. Life Finder Detectors: An Overview of Detector Technologies for Detecting Life on Other Worlds

    NASA Astrophysics Data System (ADS)

    Rauscher, Bernard J.; Domagal-Goldman, Shawn; Greenhouse, Matthew A.; Hsieh, Wen-Ting; McElwain, Michael W.; Moseley, Samuel H.; Noroozian, Omid; Norton, Tim; Kutyrev, Alexander; Rinehart, Stephen; stock, Joseph

    2015-01-01

    Future large space telescopes will seek evidence for life on other worlds by searching for spectroscopic biosignatures. Atmospheric biosignature gases include oxygen, ozone, water vapor, and methane. Non-biological gases, including carbon monoxide and carbon dioxide, are important for discriminating false positives. All of these gases imprint spectroscopic features in the UV through mid-IR that are potentially detectable using future space based coronagraphs or star shades for starlight suppression.Direct spectroscopic biosignature detection requires sensors capable of robustly measuring photon arrival rates on the order of 10 per resolution element per hour. Photon counting is required for some wavefront sensing and control approaches to achieve the requisite high contrast ratios. We review life finder detector technologies that either exist today, or are under development, that have the potential to meet these challenging requirements. We specifically highlight areas where more work or development is needed.Life finder detectors will be invaluable for a wide variety of other major science programs. Because of its cross cutting nature; UV, optical, and infrared (UVOIR) detector development features prominently in the 2010 National Research Council Decadal Survey, 'New Worlds, New Horizons in Astronomy and Astrophysics', and the NASA Cosmic Origins Program Technology Roadmap.

  1. Wide-field ultraviolet imager for astronomical transient studies

    NASA Astrophysics Data System (ADS)

    Mathew, Joice; Ambily, S.; Prakash, Ajin; Sarpotdar, Mayuresh; Nirmal, K.; G. Sreejith, A.; Safonova, Margarita; Murthy, Jayant; Brosch, Noah

    2018-04-01

    Though the ultraviolet (UV) domain plays a vital role in the studies of astronomical transient events, the UV time-domain sky remains largely unexplored. We have designed a wide-field UV imager that can be flown on a range of available platforms, such as high-altitude balloons, CubeSats, and larger space missions. The major scientific goals are the variability of astronomical sources, detection of transients such as supernovae, novae, tidal disruption events, and characterizing active galactic nuclei variability. The instrument has a 80 mm aperture with a circular field of view of 10.8 degrees, an angular resolution of ˜22 arcsec, and a 240 - 390 nm spectral observation window. The detector for the instrument is a Microchannel Plate (MCP)-based image intensifier with both photon counting and integration capabilities. An FPGA-based detector readout mechanism and real time data processing have been implemented. The imager is designed in such a way that its lightweight and compact nature are well fitted for the CubeSat dimensions. Here we present various design and developmental aspects of this UV wide-field transient explorer.

  2. Apollo scientific experiments data handbook

    NASA Technical Reports Server (NTRS)

    Eichelman, W. F. (Editor); Lauderdale, W. W. (Editor)

    1974-01-01

    A brief description of each of the Apollo scientific experiments was described, together with its operational history, the data content and formats, and the availability of the data. The lunar surface experiments described are the passive seismic, active seismic, lunar surface magnetometer, solar wind spectrometer, suprathermal ion detector, heat flow, charged particle, cold cathode gage, lunar geology, laser ranging retroreflector, cosmic ray detector, lunar portable magnetometer, traverse gravimeter, soil mechanics, far UV camera (lunar surface), lunar ejecta and meteorites, surface electrical properties, lunar atmospheric composition, lunar surface gravimeter, lunar seismic profiling, neutron flux, and dust detector. The orbital experiments described are the gamma-ray spectrometer, X-ray fluorescence, alpha-particle spectrometer, S-band transponder, mass spectrometer, far UV spectrometer, bistatic radar, IR scanning radiometer, particle shadows, magnetometer, lunar sounder, and laser altimeter. A brief listing of the mapping products available and information on the sample program were also included.

  3. ZnO nanodisk based UV detectors with printed electrodes.

    PubMed

    Alenezi, Mohammad R; Alshammari, Abdullah S; Alzanki, Talal H; Jarowski, Peter; Henley, Simon John; Silva, S Ravi P

    2014-04-08

    The fabrication of highly functional materials for practical devices requires a deep understanding of the association between morphological and structural properties and applications. A controlled hydrothermal method to produce single crystal ZnO hexagonal nanodisks, nanorings, and nanoroses using a mixed solution of zinc sulfate (ZnSO4) and hexamethylenetetramine (HMTA) without the need of catalysts, substrates, or templates at low temperature (75 °C) is introduced. Metal-semiconductor-metal (MSM) ultraviolet (UV) detectors were fabricated based on individual and multiple single-crystal zinc oxide (ZnO) hexagonal nanodisks. High quality single crystal individual nanodisk devices were fabricated with inkjet-printed silver electrodes. The detectors fabricated show record photoresponsivity (3300 A/W) and external quantum efficiency (1.2 × 10(4)), which we attribute to the absence of grain boundaries in the single crystal ZnO nanodisk and the polarity of its exposed surface.

  4. Verification of the Sentinel-4 focal plane subsystem

    NASA Astrophysics Data System (ADS)

    Williges, Christian; Uhlig, Mathias; Hilbert, Stefan; Rossmann, Hannes; Buchwinkler, Kevin; Babben, Steffen; Sebastian, Ilse; Hohn, Rüdiger; Reulke, Ralf

    2017-09-01

    The Sentinel-4 payload is a multi-spectral camera system, designed to monitor atmospheric conditions over Europe from a geostationary orbit. The German Aerospace Center, DLR Berlin, conducted the verification campaign of the Focal Plane Subsystem (FPS) during the second half of 2016. The FPS consists, of two Focal Plane Assemblies (FPAs), two Front End Electronics (FEEs), one Front End Support Electronic (FSE) and one Instrument Control Unit (ICU). The FPAs are designed for two spectral ranges: UV-VIS (305 nm - 500 nm) and NIR (750 nm - 775 nm). In this publication, we will present in detail the set-up of the verification campaign of the Sentinel-4 Qualification Model (QM). This set up will also be used for the upcoming Flight Model (FM) verification, planned for early 2018. The FPAs have to be operated at 215 K +/- 5 K, making it necessary to exploit a thermal vacuum chamber (TVC) for the test accomplishment. The test campaign consists mainly of radiometric tests. This publication focuses on the challenge to remotely illuminate both Sentinel-4 detectors as well as a reference detector homogeneously over a distance of approximately 1 m from outside the TVC. Selected test analyses and results will be presented.

  5. Ultraviolet Observations of the Earth and Moon during the Juno Flyby

    NASA Astrophysics Data System (ADS)

    Gladstone, R.; Versteeg, M. H.; Davis, M.; Greathouse, T. K.; Gerard, J. M.; Grodent, D. C.; Bonfond, B.

    2013-12-01

    We present the initial results from Juno-UVS observations of the Earth and Moon obtained during the flyby of the Juno spacecraft on 9 October 2013. Juno-UVS is an imaging spectrograph with a bandpass of 70<λ<205 nm. This wavelength range includes all important ultraviolet (UV) emissions from the H2 bands and the H Lyman series which are produced in Jupiter's auroras, and also the absorption signatures of aurorally-produced hydrocarbons. The Juno-UVS instrument consists of two separate sections: a dedicated telescope/spectrograph assembly and a vault electronics box. The telescope/spectrograph assembly contains a telescope which feeds a 0.15-m Rowland circle spectrograph. The telescope has a 4 x 4 cm2 input aperture and uses an off-axis parabolic (OAP) primary mirror. A flat scan mirror situated at the front end of the telescope (used to observe at up to ×30° perpendicular to the Juno spin plane) directs incoming light to the OAP. The light is focused onto the spectrograph entrance slit, which has a 'dog-bone' shape 7.2° long, in three sections of 0.2°, 0.025°, and 0.2° width (as projected onto the sky). Light entering the slit is dispersed by a toroidal grating which focuses UV light onto a curved microchannel plate cross delay line detector with a solar blind UV-sensitive CsI photocathode, which makes up the instrument's focal plane. Tantalum surrounds the detector assembly to shield it from high-energy electrons. The detector electronics are located behind the detector. All other electronics are located in a box inside Juno's spacecraft vault, including redundant low-voltage and high-voltage power supplies, command and data handling electronics, heater/actuator electronics, scan mirror electronics, and event processing electronics. The purpose of Juno-UVS is to remotely sense Jupiter's auroral morphology and brightness to provide context for in situ measurements by Juno's particle instruments. The recent Earth flyby provided an opportunity to: 1) use observations of the lunar surface to improve flux and wavelength calibration at EUV wavelengths λ<91 nm (for which there are few stellar calibration options); 2) test the Juno spacecraft nadir-pulse system (which will be used at Jupiter to control scan mirror movements); 3) observe Earth airglow, aurora, and geocoronal emissions (for science interest); and 4) determine the effectiveness of the Ta shielding to high-energy particles (using dark observations made during Juno's passage through Earth's radiation belts). Preliminary results for each of these objectives will be presented.

  6. Critical Technology Events in the Development of the Stinger and Javelin Missile Systems: Project Hindsight Revisited

    DTIC Science & Technology

    2006-07-01

    detector that operated at the mid-infrared made of InSb and another detector that operated at the near ultraviolet (UV) made of cadmium sulphide .26 The IR... mercury cadmium telluride (MCT) detectors, operating in the long-wave IR region of 8– 12 microns. The detectors were scanned at 30Hz in a bi-directional...of cadmium-tellurium and mercury -tellurium (termed mercury cadmium telluride or HgCdTe). Note the contrast with the CLU’s IR system,76 which is a

  7. The Austrian UVB monitoring network: 12 years of observations and 25 years of reconstructed data

    NASA Astrophysics Data System (ADS)

    Rieder, H. E.; Weihs, P.; Blumthaler, M.; Simic, S.; Schmalwieser, A. W.; Wagner, J. E.; Schallhart, B.; Schauberger, G.; Fitzka, M.; Holawe, F.; Laube, W.

    2009-04-01

    Since the discovery of anthropogenic ozone depletion in the early 1970s (e.g. Molina and Rowland, 1974; Farman et al., 1985) the interest in stratospheric ozone trends and solar UV-B increased within the scientific community and the general public because of the link between reduced total column ozone and increased UV-radiation doses. In 1996, the setup of an Austrian UVB monitoring network was initiated by the Federal Department of Environment (Blumthaler and Schauberger, 2001). Now it consists of 12 broadband detectors for measuring erythemally weighted solar UV irradiance at locations between 153 m and 3106 m above sea level. The locations of the stations were selected by objective criteria as spatial coverage and cover the whole altitude range of Austria. With that inter-stational correlation is close to 0.9 (Schmalwieser and Schauberger, 2001). All detectors are calibrated each year in the laboratory of the Division for Biomedical Physics, Innsbruck Medical University. First the relative spectral response of each detector is determined. Then by comparison with a double monochromator spectroradiometer the absolute calibration function is derived in dependence on solar zenith angle and on total atmospheric ozone (Blumthaler, 2004). The uncertainty of the calibration is about ±7% (at 95% confidence level) for solar zenith angles <75°, which is dominated by the uncertainty of the calibration lamp for the spectroradiometer (±4%). During routine operation, the measurements of all detectors are transmitted in near real time to the laboratory and then converted to UV-Indices, the internationally agreed unit for erythemally weighted solar irradiance. The results are then published on the internet (www.uv-index.at) every 15 minutes, together with a regional map showing the distribution of the UV-Index over Austria by combining the information from the measurement detectors with cloud information from Meteosat Second Generation. Recently reconstructed UV-data became available for two stations from the Austrian UVB monitoring network (Hoher Sonnblick and Vienna) (Rieder et al., 2008). An overview about the UVB monitoring network as well as studies on short and long-term trends and the influence of total ozone, surface albedo and cloudiness on erythemal UV (Weihs et al., 1999; Rieder et al., 2008; Simic et al., 2008) are presented. Results from a recent field campaign (Weihs et al., 2008) showed that maintenance of ground based measurements is very important as satellites so far do not satisfactorily represent ground UV. References: Blumthaler, M., and Ambach, W.: Solar UVB-albedo of various surfaces, Photochem. Photobiol., 48, 85-88, 1988. Blumthaler, M.: Quality assurance and quality control methodologies within the Austrian UV monitoring network, Rad. Prot. Dos., 111, 359-362, 2004. Farman, J. C., Gardiner, B. G., and Shanklin, J. D.: Large losses of total ozone in Antarctica reveal seasonal ClOx/NOx interaction, Nature, 315, 207-210, 1985. Molina, M. J., and Rowland, F. S.: Stratospheric sink for chlorofluoromethans: Chlorine atom-catalysed destruction of ozone, Nature, 249, 810-812, 1974. Rieder, H.E., Holawe, F., Simic, S., Blumthaler, M., Krzyscin, J.W., Wagner J.E., Schmalwieser A.W., and Weihs, P.: Reconstruction of erythemal UV-doses for two stations in Austria: A comparison between alpine and urban regions, Atmos. Chem. Phys., 8, 6309-6323, 2008. Simic, S., Weihs, P., Vacek, A., Kromp-Kolb, H., and Fitzka, M.: Spectral UV measurements in Austria from 1994 to 2006: investigations of short- and long-term changes, Atmos. Chem. Phys. Discuss., 8, 2403-2428, 2008. Schmalwieser, A.W., and Schauberger, G.: A monitoring network for erythemally-effective solar ultraviolet radiation in Austria: determination of the measuring sites and visualisation of the spatial distribution, Theor. Appl. Climatol., 69, 221-229, 2001. Weihs, P., Simic, S., Laube, W., Mikielewicz, W., Rengarajan, G., Mandl, G.: Albedo influences on surface UV irradiance at the Sonnblick high mountain Observatory (3106 m altitude), J. Appl. Meteorol., 38, 1599-1610, 1999. Weihs, P., Blumthaler, M., Rieder, H. E., Kreuter, A., Simic, S., Laube, W., Schmalwieser, A. W., Wagner, J. E., and Tanskanen, A.: Measurements of UV irradiance within the area of one satellite pixel, Atmos. Chem. Phys., 8, 5615-5626, 2008.

  8. AstroBioLab: A Mobile Biotic and Soil Analysis Laboratory

    NASA Technical Reports Server (NTRS)

    Bada, J. L.; Zent, A. P.; Grunthaner, F. J.; Quinn, R. C.; Navarro-Gonzalex, R.; Gonez-Silva, B.; McKay, C. P.

    2003-01-01

    The Jet Propulsion Laboratory, Scripps Institution of Oceanography, and NASA Ames Research Center are currently developing a mobile Astrobiology Laboratory (AstroBioLab) for a series of field campaigns using the Chilean Atacama Desert as a Martian surface analog site. The Astrobiology Science and Technology for Exploring Planets (ASTEP) program funded AstroBioLab is designed around the Mars Organic Detector (MOD) instrument and the Mars Oxidant Instrument (MOI) which provide complementary data sets. Using this suite of Mars Instrument Development Program (MIDP) and Planetary Instrument Definition and Development Program (PIDDP) derived in situ instruments, which provide state-of-the-art organic compound detection (attomolar sensitivity) and depth profiling of oxidation chemistry, we measure and correlate the interplay of organic compounds, inorganic oxidants, UV irradiation and water abundance. This mobile laboratory studies the proposition that intense UV irradiation coupled with low levels of liquid water generates metastable oxidizing species that can consume moderate amounts of seeded organic compounds. Results from the initial spring 2003 field campaign will be presented.

  9. Standardization of Broadband UV Measurements for 365 nm LED Sources

    PubMed Central

    Eppeldauer, George P.

    2012-01-01

    Broadband UV measurements are evaluated when UV-A irradiance meters measure optical radiation from 365 nm UV sources. The CIE standardized rectangular-shape UV-A function can be realized only with large spectral mismatch errors. The spectral power-distribution of the 365 nm excitation source is not standardized. Accordingly, the readings made with different types of UV meters, even if they measure the same UV source, can be very different. Available UV detectors and UV meters were measured and evaluated for spectral responsivity. The spectral product of the source-distribution and the meter’s spectral-responsivity were calculated for different combinations to estimate broad-band signal-measurement errors. Standardization of both the UV source-distribution and the meter spectral-responsivity is recommended here to perform uniform broad-band measurements with low uncertainty. It is shown what spectral responsivity function(s) is needed for new and existing UV irradiance meters to perform low-uncertainty broadband 365 nm measurements. PMID:26900516

  10. Development of a flight qualified 100 x 100 mm MCP UV detector using advanced cross strip anodes and associated ASIC electronics

    NASA Astrophysics Data System (ADS)

    Vallerga, John; McPhate, Jason; Tremsin, Anton; Siegmund, Oswald; Raffanti, Rick; Cumming, Harley; Seljak, Andrej; Virta, Vihtori; Varner, Gary

    2016-07-01

    Photon counting microchannel plate (MCP) imagers have been the detector of choice for most UV astronomical missions over the last three decades (e.g. EUVE, FUSE, COS on Hubble etc.) and been mentioned for instruments on future large telescopes in space such as LUVOIR14. Using cross strip anodes, improvements in the MCP laboratory readout technology have resulted in better spatial resolution (x10), temporal resolution (x 1000) and output event rate (x100), all the while operating at lower gain (x10) resulting in lower high voltage requirements and longer MCP lifetimes. A crossed strip anode MCP readout starts with a set of orthogonal conducting strips (e.g. 80 x 80), typically spaced at a 635 micron pitch onto which charge clouds from MCP amplified events land. Each strip has its own charge sensitive amplifier that is sampled continuously by a dedicated analog to digital converter (ADC). All of the ADC digital output lines are fed into a field programmable gate array (FGPA) which can detect charge events landing on the strips, measure the peak amplitudes of those charge events and calculate their spatial centroid along with their time of arrival (X,Y,T) and pass this information to a downstream computer. Laboratory versions of these electronics have demonstrated < 20 microns FWHM spatial resolution, count rates on the order of 2 MHz, and temporal resolution of 1ns. In 2012 our group at U.C. Berkeley, along with our partners at the U. Hawaii, received a NASA Strategic Astrophysics Technology (SAT) grant to raise the TRL of a cross strip detector from 4 to 6 by replacing most of the 19" rack mounted, high powered electronics with application specific integrated circuits (ASICs) which will lower the power, mass, and volume requirements of the detector electronics. We were also tasked to design and fabricate a "standard" 50mm square active area MCP detector incorporating these electronics that can be environmentally qualified for flight (temperature, vacuum, vibration). ASICs designed for this program have been successfully fabricated and are undergoing extensive testing. We will present the latest progress on these ASIC designs and their performance. We will also show our preliminary work on scaling these designs (detector and electronics) to a flight qualified 100 x 100 mm cross strip detector, which has recently been funded through a follow on SAT grant.

  11. The Ultraviolet Spectrograph (UVS) on Juno

    NASA Astrophysics Data System (ADS)

    Gladstone, G. R.; Persyn, S.; Eterno, J.; Slater, D. C.; Davis, M. W.; Versteeg, M. H.; Persson, K. B.; Siegmund, O. H.; Marquet, B.; Gerard, J.; Grodent, D. C.

    2008-12-01

    Juno, a NASA New Frontiers mission, plans for launch in August 2011, a 5-year cruise (including a flyby of Earth in October 2013 for a gravity boost), and 14 months around Jupiter after arriving in August 2016. The spinning (2 RPM), solar-powered Juno will study Jupiter from a highly elliptical orbit, in which the spacecraft (for about 6 hours once every 11 days) dives down over the north pole, skims the outermost atmosphere, and rises back up over the south pole. This orbit allows Juno avoid most of the intense particle radiation surrounding the planet and provides an excellent platform for investigating Jupiter's polar magnetosphere. Part of the exploration of Jupiter's polar magnetosphere will involve remote sensing of the far-ultraviolet H and H2 auroral emissions, plus gases such as methane and acetylene which add their absorption signature to the H2 emissions. This hydrocarbon absorption can be used to estimate the energy of the precipitating electrons; since more energetic electrons penetrate deeper into the atmosphere and the UV emissions they produce will show more absorption. Juno will carry an Ultraviolet Spectrograph (UVS) to make spectral images of Jupiter's aurora. UVS is a UV imaging spectrograph sensitive to both extreme and far ultraviolet emissions in the 70-205~nm range that will characterize the morphology and spectral nature of Jupiter's auroral emissions. Juno UVS consists of two separate sections: a dedicated telescope/spectrograph assembly and a vault electronics box. The telescope/spectrograph assembly contains a telescope which feeds a 0.15-m Rowland circle spectrograph. The telescope has an input aperture 40×40~mm2 and uses an off-axis parabolic primary mirror. A flat scan mirror situated at the front end of the telescope (used to target specific auroral features at up to ±30° perpendicular to the Juno spin plane) directs incoming light to the primary. The light is then focused onto the spectrograph entrance slit, which has a 'dog- bone' shape 6° long, in three 2° sections of 0.2°, 0.05°, and 0.2° width (projected onto the sky). Light entering the slit is dispersed by a toroidal grating which focuses the UV bandpass onto a curved microchannel plate (MCP) cross delay line (XDL) detector with a solar blind UV- sensitive CsI photocathode, which makes up the instrument's focal plane. Tantalum shielding surrounds the detector assembly to protect the detector and the adjacent detector electronics from high-energy electrons. The main electronics box is located in the Juno vault. Inside are two redundant high-voltage power supplies (HVPS), two redundant low-voltage power supplies, the command and data handling (C&DH) electronics, heater/actuator activation electronics, scan mirror electronics, and event processing electronics. An overview of the UVS design and scientific performance will be presented.

  12. Characterization of a real time H2O2 monitor for use in studies on H2O2 production by antibodies and cells.

    PubMed

    Sharma, Harish A; Balcavage, Walter X; Waite, Lee R; Johnson, Mary T; Nindl, Gabi

    2003-01-01

    It was recently shown that antibodies catalyze a reaction between water and ultraviolet light (UV) creating singlet oxygen and ultimately H2O2. Although the in vivo relevance of these antibody reactions is unclear, it is interesting that among a wide variety of non-antibody proteins tested, the T cell receptor is the only protein with similar capabilities. In clinical settings UV is believed to exert therapeutic effects by eliminating inflammatory epidermal T cells and we hypothesized that UV-triggered H2O2 production is involved in this process. To test the hypothesis we developed tools to study production of H2O2 by T cell receptors with the long-term goal of understanding, and improving, UV phototherapy. Here, we report the development of an inexpensive, real time H2O2 monitoring system having broad applicability. The detector is a Clark oxygen electrode (Pt, Ag/AgCl) modified to detect UV-driven H2O2 production. Modifications include painting the electrode black to minimize UV effects on the Ag/AgCl electrode and the use of hydrophilic, large pore Gelnots electrode membranes. Electrode current was converted to voltage and then amplified and recorded using a digital multimeter coupled to a PC. A reaction vessel with a quartz window was developed to maintain constant temperature while permitting UV irradiation of the samples. The sensitivity and specificity of the system and its use in cell-free and cell-based assays will be presented. In a cellfree system, production of H2O2 by CD3 antibodies was confirmed using our real time H2O2 monitoring method. Additionally we report the finding that splenocytes and Jurkat T cells also produce H2O2 when exposed to UV light.

  13. DURIP: Fast Oscilloscope and Detectors for Air Laser Research

    DTIC Science & Technology

    2015-01-01

    TEKTRONIX DPO73304D, 33 GHz Digital Phosphor Oscilloscope; 4 analog channels DPO70604C, 6 GHz Digital Phosphor Oscilloscope; 4 analog channels...when we focus in air intense UV pulses resonantly with two-photon transitions in atomic oxygen or nitrogen. The UV pump pulse (or an...two-­‐photon   UV  pumping  at  226nm  for  oxygen,  and  at  207  or  211nm  for   nitrogen   is   followed   by

  14. Simultaneous determination of the absolute configuration of twelve monosaccharide enantiomers from natural products in a single injection by UPLC-UV/MS method

    USDA-ARS?s Scientific Manuscript database

    In natural product chemistry, it is often crucial to determine sugar composition as well as the absolute configuration of each monosaccharide in glycosides. An ultra-performance liquid chromatography method using both photodiode array (PDA) and mass spectrometry detectors (UPLC-UV/MS) was developed....

  15. Electrophoretically mediated microanalysis of a nicotinamide adenine dinucleotide-dependent enzyme and its facile multiplexing using an active pixel sensor UV detector.

    PubMed

    Urban, Pawel L; Goodall, David M; Bergström, Edmund T; Bruce, Neil C

    2007-08-31

    An electrophoretically mediated microanalysis (EMMA) method has been developed for yeast alcohol dehydrogenase and quantification of reactant and product cofactors, NAD and NADH. The enzyme substrate ethanol (1% (v/v)) was added to the buffer (50 mM borate, pH 8.8). Results are presented for parallel capillary electrophoresis with a novel miniature UV area detector, with an active pixel sensor imaging an array of two or six parallel capillaries connected via a manifold to a single output capillary in a commercial CE instrument, allowing conversions with five different yeast alcohol dehydrogenase concentrations to be quantified in a single experiment.

  16. Microchannel plate life testing for UV spectroscopy instruments

    NASA Astrophysics Data System (ADS)

    Darling, N. T.; Siegmund, O. H. W.; Curtis, T.; McPhate, J.; Tedesco, J.; Courtade, S.; Holsclaw, G.; Hoskins, A.; Al Dhafri, S.

    2017-08-01

    The Emirates Mars Mission (EMM) UV Spectrograph (EMUS) is a far ultraviolet (102 nm to 170 nm) imaging spectrograph for characterization of the Martian exosphere and thermosphere. Imaging is accomplished by a photon counting open-face microchannel plate (MCP) detector using a cross delay line (XDL) readout. An MCP gain stabilization ("scrub") followed by lifetime spectral line burn-in simulation has been completed on a bare MCP detector at SSL. Gain and sensitivity stability of better than 7% has been demonstrated for total dose of 2.5 × 1012 photons cm-2 (2 C · cm-2 ) at 5.5 kHz mm-2 counting rates, validating the efficacy of an initial low gain full-field scrub.

  17. Future Trends in MIcroelectronics: Up the Nano Creek

    DTIC Science & Technology

    2006-06-01

    developed focal plane arrays (FPA)3𔃾 in addition to emphasizing future development in UV-to-far infrared multicolor FPA detectors 5𔄀 for next generation... detectors ", IEEE J. Quantum Electronics 35, 1685 (1999). 3. P. Bois, E. Costard, X. Marcadet, and E. Herniou, "Development of quantum well infrared ...photodetector array", Infrared Phys. Technol. 44, 369 (2003). 5. M. N. Abedin, T. F. Refaat, J. M. Zawodny, et al., "Multicolor focal plane array detector

  18. Modifications in the optical and thermal properties of a CR-39 polymeric detector induced by high doses of γ-radiation

    NASA Astrophysics Data System (ADS)

    Saad, A. F.; Ibraheim, Mona H.; Nwara, Aya M.; Kandil, S. A.

    2018-04-01

    Effects of γ-radiation on the optical and thermal properties of a poly allyl diglycol carbonate (PADC), a form of CR-39, polymer have been investigated. CR-39 detectors were exposed to γ-rays at very high doses ranging from 5.0 × 105 to 3.0 × 106 Gy. The induced changes were analyzed using ultraviolet-visible spectroscopy (UV-VIS) in absorbance mode, and thermogravimetric analysis (TGA). The UV-visible spectra of the virgin and γ-irradiated CR-39 polymer detectors displayed a significant decreasing trend in their optical energy band gaps for indirect transitions, whereas for the direct ones showed a little change. This drop in the energy band gap with increasing dose is discussed on the basis of the gamma irradiation induced modifications in the CR-39 polymeric detector. The TGA thermograms show that the weight loss rate increased with increase in dose, which may be due to the disordered system via scission followed by crosslinking in the irradiated polymer detector. The TGA thermograms also indicated that the CR-39 detector decomposed in three/four stages for the virgin and irradiated samples. The activation energy for thermal decomposition was determined using a type of Arrhenius equation based on the TGA experimental results. These experimental results so obtained can be well used in radiation dosimetry.

  19. LYRA, solar uv radiometer on the technology demonstration platform PROBA-2

    NASA Astrophysics Data System (ADS)

    Stockman, Y.; Hochedez, J.-F.; Schmutz, W.; BenMoussa, A.; Defise, J.-M.; Denis, F.; D'Olieslaeger, M.; Dominique, M.; Haenen, K.; Halain, J.-P.; Koller, S.; Koizumi, S.; Mortet, V.; Rochus, P.; Schühle, U.; Soltani, A.; Theissen, A.

    2017-11-01

    LYRA is a solar radiometer part of the PROBA 2 micro satellite payload. LYRA will monitor the solar irradiance in four soft X-Ray - VUV passbands. They have been chosen for their relevance to Solar Physics, Aeronomy and SpaceWeather: 1/ Lyman Alpha channel, 2/ Herzberg continuum range, 3/ Aluminium filter channel (including He II at 30.4 nm) and 4/ Zirconium filter channel. The radiometric calibration is traceable to synchrotron source standards. The stability will be monitored by on-board calibration sources (LEDs), which allow us to distinguish between potential degradations of the detectors and filters. Additionally, a redundancy strategy maximizes the accuracy and the stability of the measurements. LYRA will benefit from wide bandgap detectors based on diamond: it will be the first space assessment of revolutionary UV detectors. Diamond sensors make the instruments radiation-hard and solar-blind (insensitive to visible light) and therefore, make dispensable visible light blocking filters. To correlate the data of this new detector technology, well known technology, such as Si detectors are also embarked. The SWAP EUV imaging telescope will operate next to LYRA on PROBA-2. Together, they will provide a high performance solar monitor for operational space weather nowcasting and research. LYRA demonstrates technologies important for future missions such as the ESA Solar Orbiter.

  20. Solar-blind ultraviolet optical system design for missile warning

    NASA Astrophysics Data System (ADS)

    Chen, Yu; Huo, Furong; Zheng, Liqin

    2015-03-01

    Solar-blind region of Ultraviolet (UV) spectrum has very important application in military field. The spectrum range is from 240nm to 280nm, which can be applied to detect the tail flame from approaching missile. A solar-blind UV optical system is designed to detect the UV radiation, which is an energy system. iKon-L 936 from ANDOR company is selected as the UV detector, which has pixel size 13.5μm x 13.5 μm and active image area 27.6mm x 27.6 mm. CaF2 and F_silica are the chosen materials. The original structure is composed of 6 elements. To reduce the system structure and improve image quality, two aspheric surfaces and one diffractive optical element are adopted in this paper. After optimization and normalization, the designed system is composed of five elements with the maximum spot size 11.988μ m, which is less than the pixel size of the selected CCD detector. Application of aspheric surface and diffractive optical element makes each FOV have similar spot size, which shows the system almost meets the requirements of isoplanatic condition. If the focal length can be decreased, the FOV of the system can be enlarged further.

  1. UV-visible sensors based on polymorphous silicon

    NASA Astrophysics Data System (ADS)

    Guedj, Cyril S.; Cabarrocas, Pere R. i.; Massoni, Nicolas; Moussy, Norbert; Morel, Damien; Tchakarov, Svetoslav; Bonnassieux, Yvan

    2003-09-01

    UV-based imaging systems can be used for low-altitude rockets detection or biological agents identification (for instance weapons containing ANTHRAX). Compared to conventional CCD technology, CMOS-based active pixel sensors provide several advantages, including excellent electro-optical performances, high integration, low voltage operation, low power consumption, low cost, long lifetime, and robustness against environment. The monolithic integration of UV, visible and infrared detectors on the same uncooled CMOS smart system would therefore represent a major advance in the combat field, for characterization and representation of targets and backgrounds. In this approach, we have recently developped a novel technology using polymorphous silicon. This new material, fully compatible with above-IC silicon technology, is made of nanometric size ordered domains embedded in an amorphous matrix. The typical quantum efficiency of detectors made of this nano-material reach up to 80 % at 550 nm and 30 % in the UV range, depending of the design and the growth parameters. Furthermore, a record dark current of 20 pA/cm2 at -3 V has been reached. In addition, this new generation of sensors is significantly faster and more stable than their amorphous silicon counterparts. In this paper, we will present the relationship between the sensor technology and the overall performances.

  2. Particle-fluorescence spectrometer for real-time single-particle measurements of atmospheric organic carbon and biological aerosol.

    PubMed

    Pan, Yong-Le; Pinnick, Ronald G; Hill, Steven C; Chang, Richard K

    2009-01-15

    A particle-fluorescence spectrometer (PFS) for real-time measurements of single-particle UV-laser-induced fluorescence (UV-LIF) excited with a pulsed (263-nm) laser is reported. The dispersed UV-LIF spectra are measured by a 32-anode PMT detector with spectral coverage from 280-600 nm. The PFS represents a significant improvement over our previous apparatus [Pinnick et al., Atmos. Environ. 2004, 38, 1657] and can (1) measure fluorescence spectra of bacterial particles having light-scattering sizes as small as 1 microm (previously limited to about 3 microm) and so can measure particles with size in the range of 1-10 microm, (2) measure each particle's elastic scattering which can be used to estimate particle size (not available previously), (3) measure single-particle fluorescence spectra with a laser and detector that can record spectra as fast as 90,000/s, although the highest rates we have found experimentally in atmospheric measurements is only several hundred per second (previously limited by detectors to only 25/s), and (4) provide a time stamp for a data block of spectra with time resolution from 10 ms to 10 min. In addition, the PFS has been modified to be more robust, transportable, and smaller. The use of an aerodynamic-focusing sheath inlet nozzle assembly has improved the sample rate. The PFS has been employed to measure UV-LIF spectra from individual atmospheric particles during October-December 2006 and January-May 2008 in New Haven, CT, and during January-May 2007 in Las Cruces, NM.

  3. Evaluation of Hydrodynamic Chromatography Coupled with UV-Visible, Fluorescence and Inductively Coupled Plasma Mass Spectrometry Detectors for Sizing and Quantifying Colloids in Environmental Media

    PubMed Central

    Philippe, Allan; Schaumann, Gabriele E.

    2014-01-01

    In this study, we evaluated hydrodynamic chromatography (HDC) coupled with inductively coupled plasma mass spectrometry (ICP-MS) for the analysis of nanoparticles in environmental samples. Using two commercially available columns (Polymer Labs-PDSA type 1 and 2), a set of well characterised calibrants and a new external time marking method, we showed that flow rate and eluent composition have few influence on the size resolution and, therefore, can be adapted to the sample particularity. Monitoring the agglomeration of polystyrene nanoparticles over time succeeded without observable disagglomeration suggesting that even weak agglomerates can be measured using HDC. Simultaneous determination of gold colloid concentration and size using ICP-MS detection was validated for elemental concentrations in the ppb range. HDC-ICP-MS was successfully applied to samples containing a high organic and ionic background. Indeed, online combination of UV-visible, fluorescence and ICP-MS detectors allowed distinguishing between organic molecules and inorganic colloids during the analysis of Ag nanoparticles in synthetic surface waters and TiO2 and ZnO nanoparticles in commercial sunscreens. Taken together, our results demonstrate that HDC-ICP-MS is a flexible, sensitive and reliable method to measure the size and the concentration of inorganic colloids in complex media and suggest that there may be a promising future for the application of HDC in environmental science. Nonetheless the rigorous measurements of agglomerates and of matrices containing natural colloids still need to be studied in detail. PMID:24587393

  4. Evaluation of hydrodynamic chromatography coupled with UV-visible, fluorescence and inductively coupled plasma mass spectrometry detectors for sizing and quantifying colloids in environmental media.

    PubMed

    Philippe, Allan; Schaumann, Gabriele E

    2014-01-01

    In this study, we evaluated hydrodynamic chromatography (HDC) coupled with inductively coupled plasma mass spectrometry (ICP-MS) for the analysis of nanoparticles in environmental samples. Using two commercially available columns (Polymer Labs-PDSA type 1 and 2), a set of well characterised calibrants and a new external time marking method, we showed that flow rate and eluent composition have few influence on the size resolution and, therefore, can be adapted to the sample particularity. Monitoring the agglomeration of polystyrene nanoparticles over time succeeded without observable disagglomeration suggesting that even weak agglomerates can be measured using HDC. Simultaneous determination of gold colloid concentration and size using ICP-MS detection was validated for elemental concentrations in the ppb range. HDC-ICP-MS was successfully applied to samples containing a high organic and ionic background. Indeed, online combination of UV-visible, fluorescence and ICP-MS detectors allowed distinguishing between organic molecules and inorganic colloids during the analysis of Ag nanoparticles in synthetic surface waters and TiO₂ and ZnO nanoparticles in commercial sunscreens. Taken together, our results demonstrate that HDC-ICP-MS is a flexible, sensitive and reliable method to measure the size and the concentration of inorganic colloids in complex media and suggest that there may be a promising future for the application of HDC in environmental science. Nonetheless the rigorous measurements of agglomerates and of matrices containing natural colloids still need to be studied in detail.

  5. Enhancement of UV photodetector properties of ZnO nanorods/PEDOT:PSS Schottky junction by NGQD sensitization along with conductivity improvement of PEDOT:PSS by DMSO additive

    NASA Astrophysics Data System (ADS)

    Dhar, Saurab; Majumder, Tanmoy; Chakraborty, Pinak; Mondal, Suvra Prakash

    2018-04-01

    Schottky junction ultraviolet (UV) photodetector was fabricated by spin coating a hole conducting polymer, poly 3,4-ethylenedioxythiophene: polystyrene sulfonate (PEDOT:PSS) on hydrothermally grown zinc oxide (ZnO) nanorod arrays. The UV detector performance was significantly improved two step process. Firstly, ZnO nanorods were modified by sensitizing N doped grapheme quantum dots (NGQDs) for better photoresponce behavior. Afterwards, the junction properties as well as photoresponse was enhanced by modifying electrical conductivity of PEDOT:PSS layer with organic solvent (DMSO). Our NGQD decorated ZnO NRs/DMSO-PEDOT:PSS Schottky junction device demonstrated superior external quantum efficiency (EQE ˜ 90063 %) and responsivity (Rλ˜247 A/W) at 340 nm wavelength and -1V external bias. The response and recovery times of the final photodetector device was very fast compared to GQD as well as NGQD modified and pristine ZnO nanorod based detectors.

  6. An estimation methode for measurement of ultraviolet radiation during nondestructive testing

    NASA Astrophysics Data System (ADS)

    Hosseinipanah, M.; Movafeghi, A.; Farvadin, D.

    2018-04-01

    Dye penetrant testing and magnetic particle testing are among conventional NDT methods. For increased sensitivity, fluorescence dyes and particles can be used with ultraviolet (black) lights. UV flaw detection lights have different spectra. With the help of photo-filters, the output lights are transferred to UV-A and visible zones. UV-A light can be harmful to human eyes in some conditions. In this research, UV intensity and spectrum were obtained by a Radio-spectrometer for two different UV flaw detector lighting systems. According to the standards such as ASTM E709, UV intensity must be at least 10 W/m2 at a distance of 30 cm. Based on our measurements; these features not achieved in some lamps. On the other hand, intensity and effective intensity of UV lights must be below the some limits for prevention of unprotected eye damage. NDT centers are usually using some type of UV measuring devices. A method for the estimation of effective intensity of UV light has been proposed in this research.

  7. Determination of Prometryne in water and soil by HPLC-UV using cloud-point extraction.

    PubMed

    Zhou, Jihai; Chen, Jiandong; Cheng, Yanhong; Li, Daming; Hu, Feng; Li, Huixin

    2009-07-15

    A CPE-HPLC (UV) method has been developed for the determination of Prometryne. In this method, non-ionic surfactant Triton X-114 was first used to extract and pre-concentrate Prometryne from water and soil samples. The separation and determination of Prometryne were then carried out in an HPLC-UV system with isocratic elution using a detector set at 254 nm wavelength. The parameters and variables that affected the extraction were also investigated and the optimal conditions were found to be 0.5% of Triton X-114 (w/v), 3% of NaCl (w/v) and heat-assisted at 50 degrees C for 30 min. Using these conditions, the recovery rates of Prometryne ranged from 92.84% to 99.23% in water and 85.48% to 93.67% in soil, respectively, with all the relative standard deviations less than 3.05%. Limit of detection (LOD) and limit of quantification (LOQ) were 3.5 microg L(-1) and 11.0 microg L(-1) in water and 4.0 microg kg(-1) and 13.0 microg kg(-1) in soil, respectively. Thus, we developed a method that has proven to be an efficient, green, rapid and inexpensive approach for extraction and determination of Prometryne from soil samples.

  8. Updates on the Performance and Calibration of HST/STIS

    NASA Astrophysics Data System (ADS)

    Lockwood, Sean A.; Monroe, TalaWanda R.; Ogaz, Sara; Branton, Doug; Carlberg, Joleen K.; Debes, John H.; Jedrzejewski, Robert I.; Proffitt, Charles R.; Riley, Allyssa; Sohn, Sangmo Tony; Sonnentrucker, Paule; Walborn, Nolan R.; Welty, Daniel

    2018-06-01

    The Space Telescope Imaging Spectrograph (STIS) on the Hubble Space Telescope (HST) has been in orbit for 21 years and continues to produce high quality scientific results using a diverse complement of operating modes. These include spatially resolved spectroscopy in the UV and optical, high spatial resolution echelle spectroscopy in the UV, and solar-blind imaging in the UV. In addition, STIS possesses unique visible-light coronagraphic modes that keep the instrument at the forefront of exoplanet and debris-disk research. As the instrument's characteristics evolve over its lifetime, the instrument team at the Space Telescope Science Institute monitors its performance and works towards improving the quality of its data products. Here we present updates on the status of the STIS CCD and FUV & NUV MAMA detectors, as well as changes to the CalSTIS reduction pipeline. We also discuss progress toward the recalibration of the E140M/1425 echelle mode. The E140M grating blaze function shapes have changed since flux calibration was carried out following SM4, which limits the relative photometric flux accuracy of some spectral orders up to 5-10% at the edges. In Cycle 25 a special calibration program was executed to obtain updated sensitivity curves for the E140M/1425 setting.

  9. Enhanced ultraviolet photo-response in Dy doped ZnO thin film

    NASA Astrophysics Data System (ADS)

    Kumar, Pawan; Singh, Ranveer; Pandey, Praveen C.

    2018-02-01

    In the present work, a Dy doped ZnO thin film deposited by the spin coating method has been studied for its potential application in a ZnO based UV detector. The investigations on the structural property and surface morphology of the thin film ensure that the prepared samples are crystalline and exhibit a hexagonal crystal structure of ZnO. A small change in crystallite size has been observed due to Dy doping in ZnO. AFM analysis ascertains the grain growth and smooth surface of the thin films. The Dy doped ZnO thin film exhibits a significant enhancement in UV region absorption as compared to the pure ZnO thin film, which suggests that Dy doped ZnO can be used as a UV detector. Under UV irradiation of wavelength 325 nm, the photocurrent value of Dy doped ZnO is 105.54 μA at 4.5 V, which is 31 times greater than that of the un-doped ZnO thin film (3.39 μA). The calculated value of responsivity is found to increase significantly due to the incorporation of Dy in the ZnO lattice. The observed higher value of photocurrent and responsivity could be attributed to the substitution of Dy in the ZnO lattice, which enhances the conductivity, electron mobility, and defects in ZnO and benefits the UV sensing property.

  10. On-line high-performance liquid chromatography-ultraviolet-nuclear magnetic resonance method of the markers of nerve agents for verification of the Chemical Weapons Convention.

    PubMed

    Mazumder, Avik; Gupta, Hemendra K; Garg, Prabhat; Jain, Rajeev; Dubey, Devendra K

    2009-07-03

    This paper details an on-flow liquid chromatography-ultraviolet-nuclear magnetic resonance (LC-UV-NMR) method for the retrospective detection and identification of alkyl alkylphosphonic acids (AAPAs) and alkylphosphonic acids (APAs), the markers of the toxic nerve agents for verification of the Chemical Weapons Convention (CWC). Initially, the LC-UV-NMR parameters were optimized for benzyl derivatives of the APAs and AAPAs. The optimized parameters include stationary phase C(18), mobile phase methanol:water 78:22 (v/v), UV detection at 268nm and (1)H NMR acquisition conditions. The protocol described herein allowed the detection of analytes through acquisition of high quality NMR spectra from the aqueous solution of the APAs and AAPAs with high concentrations of interfering background chemicals which have been removed by preceding sample preparation. The reported standard deviation for the quantification is related to the UV detector which showed relative standard deviations (RSDs) for quantification within +/-1.1%, while lower limit of detection upto 16mug (in mug absolute) for the NMR detector. Finally the developed LC-UV-NMR method was applied to identify the APAs and AAPAs in real water samples, consequent to solid phase extraction and derivatization. The method is fast (total experiment time approximately 2h), sensitive, rugged and efficient.

  11. The Southwest Research Institute ultraviolet reflectance chamber (SwURC): a far ultraviolet reflectometer

    NASA Astrophysics Data System (ADS)

    Winters, Gregory S.; Retherford, Kurt D.; Davis, Michael W.; Escobedo, Stephen M.; Bassett, Eric C.; Patrick, Edward L.; Nagengast, Maggie E.; Fairbanks, Matthew H.; Miles, Paul F.; Parker, Joel W.; Gladstone, G. Randall; Slater, David C.; Stern, S. Alan

    2012-10-01

    We designed and assembled a highly capable UV reflectometer chamber and data acquisition system to provide bidirectional scattering data of various surfaces and materials. This chamber was initially conceived to create laboratory-based UV reflectance measurements of water frost on lunar soil/regolith simulants, to support interpretation of UV reflectance data from the Lyman Alpha Mapping Project ("LAMP") instrument on-board the NASA Lunar Reconnaissance Orbiter spacecraft. A deuterium lamp illuminates surfaces and materials at a fixed 45° incident beam angle over the 115 to 200 nm range via a monochromator, while a photomultiplier tube detector is scanned to cover emission angles -85° to +85° (with a gap from -60° to -30°, due to the detector blocking the incident beam). Liquid nitrogen cools the material/sample mount when desired. The chamber can be configured to test a wide range of samples and materials using sample trays and holders. Test surfaces to date include aluminum mirrors, water ice, reflectance standards, and frozen mixtures of water and lunar soil/regolith stimulant. Future UV measurements planned include Apollo lunar samples, meteorite samples, other ices, minerals, and optical surfaces. Since this chamber may well be able to provide useful research data for groups outside Southwest Research Institute, we plan to take requests from and collaborate with others in the UV and surface reflection research community.

  12. Fully solution processed Al-TiO2-Si (MIS) structured photo-detector

    NASA Astrophysics Data System (ADS)

    Mondal, Sandip; Kumar, Arvind

    2018-05-01

    We demonstrate the fabrication of a high performance photo detector by fully solution processed technique. The detector is fabricated with photo sensitive, low temperature (200˚C) and sol-gel processed titanium dioxide (TiO2) dielectric material on silicon substrate in the form of MIS structure with top aluminum gate. The optical detection experiment is performed on Al—TiO2—Si (MIS) device by measuring the capacitance—voltage (CV at 100 kHz) curve within the visible region of light (365 — 700 nm). The presence of light shift the flat band voltage (VFB) from 290 mV to 360 mV due to the generation of photo activated charge carriers by UV (365 nm) and white light, respectively. Moreover, the generation of the charge carrier increases drastically by the combination of UV and white, which resulting as a very large shift (600 mV) in the VFB. The entire experiment was performed in normal lab conditions with open air environment, without any clean room facility.

  13. Calibration of space instruments at the Metrology Light Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klein, R., E-mail: roman.klein@ptb.de; Fliegauf, R.; Gottwald, A.

    2016-07-27

    PTB has more than 20 years of experience in the calibration of space-based instruments using synchrotron radiation to cover the UV, VUV and X-ray spectral range. New instrumentation at the electron storage ring Metrology Light Source (MLS) opens up extended calibration possibilities within this framework. In particular, the set-up of a large vacuum vessel that can accommodate entire space instruments opens up new prospects. Moreover, a new facility for the calibration of radiation transfer source standards with a considerably extended spectral range has been put into operation. Besides, characterization and calibration of single components like e.g. mirrors, filters, gratings, andmore » detectors is continued.« less

  14. Shot noise limited characterization of ultraweak femtosecond pulse trains.

    PubMed

    Schwartz, Osip; Raz, Oren; Katz, Ori; Dudovich, Nirit; Oron, Dan

    2011-01-17

    Ultrafast science is inherently, due to the lack of fast enough detectors and electronics, based on nonlinear interactions. Typically, however, nonlinear measurements require significant powers and often operate in a limited spectral range. Here we overcome the difficulties of ultraweak ultrafast measurements by precision time-domain localization of spectral components. We utilize this for linear self-referenced characterization of pulse trains having ∼ 1 photon per pulse, a regime in which nonlinear techniques are impractical, at a temporal resolution of ∼ 10 fs. This technique does not only set a new scale of sensitivity in ultrashort pulse characterization, but is also applicable in any spectral range from the near-infrared to the deep UV.

  15. GaN-Based Detector Enabling Technology for Next Generation Ultraviolet Planetary Missions

    NASA Technical Reports Server (NTRS)

    Aslam, S.; Gronoff, G.; Hewagama, T.; Janz, S.; Kotecki, C.

    2012-01-01

    The ternary alloy AlN-GaN-InN system provides several distinct advantages for the development of UV detectors for future planetary missions. First, (InN), (GaN) and (AlN) have direct bandgaps 0.8, 3.4 and 6.2 eV, respectively, with corresponding wavelength cutoffs of 1550 nm, 365 nm and 200 nm. Since they are miscible with each other, these nitrides form complete series of indium gallium nitride (In(sub l-x)Ga(sub x)N) and aluminum gallium nitride (Al(sub l-x)Ga(sub x)N) alloys thus allowing the development of detectors with a wavelength cut-off anywhere in this range. For the 2S0-365 nm spectral wavelength range AlGaN detectors can be designed to give a 1000x solar radiation rejection at cut-off wavelength of 325 nm, than can be achieved with Si based detectors. For tailored wavelength cut-offs in the 365-4S0 nm range, InGaN based detectors can be fabricated, which still give 20-40x better solar radiation rejection than Si based detectors. This reduced need for blocking filters greatly increases the Detective Quantum efficiency (DQE) and simplifies the instrument's optical systems. Second, the wide direct bandgap reduces the thermally generated dark current to levels allowing many observations to be performed at room temperature. Third, compared to narrow bandgap materials, wide bandgap semiconductors are significantly more radiation tolerant. Finally, with the use of an (AI, In)GaN array, the overall system cost is reduced by eliminating stringent Si CCD cooling systems. Compared to silicon, GaN based detectors have superior QE based on a direct bandgap and longer absorption lengths in the UV.

  16. Analysis of synthetic derivatives of peptide hormones by capillary zone electrophoresis and micellar electrokinetic chromatography with ultraviolet-absorption and laser-induced fluorescence detection.

    PubMed

    Solínová, Veronika; Kasicka, Václav; Koval, Dusan; Barth, Tomislav; Ciencialová, Alice; Záková, Lenka

    2004-08-25

    Capillary zone electrophoresis (CZE) and micellar electrokinetic chromatography (MEKC) were used for the analysis of new synthetic derivatives of hypophysis neurohormones--vasopressin and oxytocin, and pancreatic hormone--human insulin (HI) and its octapeptide fragment, derivatized by fluorescent probe, 4-chloro-7-nitrobenzo[1,2,5]oxadiazol (NBD). The suitable composition of background electrolytes (BGEs) was selected on the basis of calculated pH dependence of effective charge of analyzed peptides. Basic ionogenic peptides were analyzed by CZE in the acidic BGE composed of 100 mM H3PO4, 50 mM Tris, pH 2.25. The ionogenic peptides with fluorescent label, NBD, were analyzed in 0.5 M acetic acid, pH 2.5. The best MEKC separation of non-ionogenic peptides was achieved in alkaline BGE, 20 mM Tris, 5 mM H3PO4, with micellar pseudophase formed by 50 mM sodium dodecylsulfate (SDS), pH 8.8. Selected characteristics (noise, detectability of substance, sensitivity of detector) of the UV-absorption detectors (single wavelength detector, multiple-wavelength photodiode array detector (PDA), both of them operating at constant wavelength 206 nm) and laser-induced fluorescence (LIF) detector (excitation/emission wavelength 488/520 nm) were determined. The detectability of peptides in the single wavelength detector was 1.3-6.0 micromol dm(-3) and in the PDA detector 1.6-3.1 micromol dm(-3). The LIF detection was more sensitive, the applied concentration of NBD derivative of insulin fragment in CZE analysis with LIF detection was three orders lower than in CZE with UV-absorption detector, and the detectability of this peptide was improved to 15.8 nmol dm(-3).

  17. Development of a new first-aid biochemical detector

    NASA Astrophysics Data System (ADS)

    Hu, Jingfei; Liao, Haiyang; Su, Shilin; Ding, Hao; Liu, Suquan

    2016-10-01

    The traditional biochemical detector exhibits poor adaptability, inconvenient carrying and slow detection, which can't meet the needs of first-aid under field condition like natural or man-made disasters etc. Therefore a scheme of first-aid biochemical detector based on MOMES Micro Spectrometer, UV LED and Photodiode was proposed. An optical detection structure combined continuous spectrum sweep with fixed wavelength measurement was designed, which adopted mobile detection optical path consisting of Micro Spectrometer and Halogen Lamp to detect Chloride (Cl-), Creatinine (Cre), Glucose (Glu), Hemoglobin (Hb). The UV LED and Photodiode were designed to detect Potassium (K-), Carbon dioxide (CO2), Sodium (Na+). According to the field diagnosis and treatment requirements, we designed the embedded control hardware circuit and software system, the prototype of first-aid biochemical detector was developed and the clinical trials were conducted. Experimental results show that the sample's absorbance repeatability is less than 2%, the max coefficient of variation (CV) in the batch repeatability test of all 7 biochemical parameters in blood samples is 4.68%, less than the clinical requirements 10%, the correlation coefficient (R2) in the clinical contrast test with AU5800 is almost greater than 0.97. To sum up, the prototype meets the requirements of clinical application.

  18. Improved Photo-Detection Using Zigzag TiO2 Nanostructures as an Active Medium.

    PubMed

    Tiwari, A K; Mondal, A; Mahajan, B K; Choudhuri, B; Goswami, T; Sarkar, M B; Chakrabartty, S; Ngangbam, C; Saha, S

    2015-07-01

    Zigzag TiO2 nanostructures were fabricated using oblique angle deposition technique. The field emission gun-scanning electron microscope (FEG-SEM) image shows that the TiO2 zigzag nanostructures were ~500 nm in length. Averagely two times enhanced UV-Vis absorption was recorded for zigzag structure compared to perpendicular TiO2 nanowires. The main band transition was observed at ~3.4 eV. The zigzag TiO2 exhibited high turn on voltage (+11 V) than that of nanowire (+2 V) detector under dark which were reduced to +0.2 V and +1.0 V under white light illumination, respectively. A maximum ~6 fold photo-responsivity was observed for the zigzag TiO2 compared with nanowire device at + 1.0 V applied potential. The maximum photo-responsivity of 0.36 A/W at 370 nm was measured for the zigzag TiO2 detector. The TiO2 zigzag detector showed slow response with rise time of 10.2 s and fall time of 10.3 s respectively. The UV (370 nm) to visible (450 nm) wavelength rejection ratio of photo-responsivity was recorded ~4 times for the detector.

  19. NARSTO NE MODEL

    Atmospheric Science Data Center

    2018-04-09

    ... UV Ozone Detector Location:  Northeastern United States Spatial Coverage:  Data are provided from seven ... Related Data:  Spatial Coverage: Northeastern United States NARSTO Northeast SCAR-B Block:  ...

  20. Laser-Induced Breakdown Spectroscopy: Capabilities and Applications

    DTIC Science & Technology

    2010-07-01

    substances such as drugs, counterfeit goods, and laundered money . It may even be possible to pinpoint specific manufacturing facilities based on...point detection or standoff mode operation. LIBS used in conjunction with broadband detectors (ultraviolet [ UV ]-visible[VIS]-near-infrared[NIR] spectral...lines in the UV -VIS-NIR spectral range. Although most early LIBS applications involved metal targets, LIBS has recently been applied to a variety

  1. NARSTO ICARTT NEAX 2004 DOE G-1 DATA

    Atmospheric Science Data Center

    2018-04-09

    ... Probe Chemiluminescence UV Ozone Detector Pulsed Fluorescence HPLC Aerosol Spectrometer Probe Pyranometer Photometer ... Carbon Monixide Hydrogen Peroxide Sulfate Particles Nitrate Particles Crustal Particles Order Data:  ...

  2. Neutron detector using sol-gel absorber

    DOEpatents

    Hiller, John M.; Wallace, Steven A.; Dai, Sheng

    1999-01-01

    An neutron detector composed of fissionable material having ions of lithium, uranium, thorium, plutonium, or neptunium, contained within a glass film fabricated using a sol-gel method combined with a particle detector is disclosed. When the glass film is bombarded with neutrons, the fissionable material emits fission particles and electrons. Prompt emitting activated elements yielding a high energy electron contained within a sol-gel glass film in combination with a particle detector is also disclosed. The emissions resulting from neutron bombardment can then be detected using standard UV and particle detection methods well known in the art, such as microchannel plates, channeltrons, and silicon avalanche photodiodes.

  3. 75 FR 22240 - Cyprodinil; Pesticide Tolerances

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-28

    ... chromatography with ultraviolet detector (HPLC/UV)) is available to enforce the tolerance expression on plant commodities. In addition, a high performance liquid chromatography with mass spectrometry (HPLC/MS) method...

  4. Fabrication of high responsivity deep UV photo-detector based on Na doped ZnO nanocolumns

    NASA Astrophysics Data System (ADS)

    Agrawal, Jitesh; Dixit, Tejendra; Palani, I. A.; Ramachandra Rao, M. S.; Singh, Vipul

    2018-05-01

    We report a variety of the hydrothermally synthesized ZnO nanostructures with a significant suppression in defect-related emission and huge enhancement in the photo-current to the dark current ratio (approximately six orders of magnitude) upon UV light illumination. Interestingly, the photo-detector shows lower dark current of 1.6 nA with high responsivity of 507 A W‑1 at 254 nm. Here, a systematic analysis of the growth process as well as the physical, chemical and electrical properties of as-grown ZnO nanostructures has been performed. We have utilized the duo effect of both the inorganic (KMnO4) and organic (Na3C6H5O7) additives, which has facilitated the precise tuning of the morphology and intrinsic defects in nanostructures that have made an impact on the photo-responsivity, photoluminescence (PL) and adhesivity of the film on to the underlying substrate. PL analysis of as-grown ZnO nanostructures has suggested 11 times improvement in the near band emission (NBE) to defect level emission (DLE) ratio. Interestingly, thermal annealing of the samples has shown a dramatic change in the morphology with significant improvement in the crystallinity. Notably, the band gap was observed to be modulated from 3.3 eV to 3.1 eV after annealing. In addition to UV photo-detector based applications, the work presented here has provided a subtle solution towards the rectification of various problems pertaining to hydrothermal processes like poor adhesivity, feeble UV emission and problem in precise tuning of the morphology along with the bandgap in one go. Therefore, these investigations assume critical significance towards the development of next-generation optoelectronic devices.

  5. Microchannel Plate Imaging Detectors for the Ultraviolet

    NASA Technical Reports Server (NTRS)

    Siegmund, O. H. W.; Gummin, M. A.; Stock, J.; Marsh, D.

    1992-01-01

    There has been significant progress over the last few years in the development of technologies for microchannel plate imaging detectors in the Ultraviolet (UV). Areas where significant developments have occurred include enhancements of quantum detection efficiency through improved photocathodes, advances in microchannel plate performance characteristics, and development of high performance image readout techniques. The current developments in these areas are summarized, with their applications in astrophysical instrumentation.

  6. A four parameter optimization and troubleshooting of a RPLC - charged aerosol detection stability indicating method for determination of S-lysophosphatidylcholines in a phospholipid formulation.

    PubMed

    Tam, James; Ahmad, Imad A Haidar; Blasko, Andrei

    2018-06-05

    A four parameter optimization of a stability indicating method for non-chromophoric degradation products of 1,2-distearoyl-sn-glycero-3-phosphocholine (DSPC), 1-stearoyl-sn-glycero-3-phosphocholine and 2-stearoyl-sn-glycero-3-phosphocholine was achieved using a reverse phase liquid chromatography-charged aerosol detection (RPLC-CAD) technique. Using the hydrophobic subtraction model of selectivity, a core-shell, polar embedded RPLC column was selected followed by gradient-temperature optimization, resulting in ideal relative peak placements for a robust, stability indicating separation. The CAD instrument parameters, power function value (PFV) and evaporator temperature were optimized for lysophosphatidylcholines to give UV absorbance detector-like linearity performance within a defined concentration range. The two lysophosphatidylcholines gave the same response factor in the selected conditions. System specific power function values needed to be set for the two RPLC-CAD instruments used. A custom flow-divert profile, sending only a portion of the column effluent to the detector, was necessary to mitigate detector response drifting effects. The importance of the PFV optimization for each instrument of identical build and how to overcome recovery issues brought on by the matrix effects from the lipid-RP stationary phase interaction is reported. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. ATLAST Detector Needs for Direct Spectroscopic Biosignature Characterization in the Visible and Near-IR

    NASA Technical Reports Server (NTRS)

    Rauscher, Bernard J.; Bolcar, Matthew R.; Clampin, Mark; Domagal-Goldman, Shawn D.; McElwain, Michael W.; Moseley, S. H.; Stahle, Carl; Stark, Christopher C.; Thronson, Harley A.

    2015-01-01

    Are we alone? Answering this ageless question will be a major focus for astrophysics in coming decades. Our tools will include unprecedentedly large UV-Optical-IR space telescopes working with advanced coronagraphs and starshades. Yet, these facilities will not live up to their full potential without better detectors than we have today. To inform detector development, this paper provides an overview of visible and near-IR (VISIR; lambda = 0.4 - 1.8 micrometers) detector needs for the Advanced Technology Large Aperture Space Telescope (ATLAST), specifically for spectroscopic characterization of atmospheric biosignature gasses. We also provide a brief status update on some promising detector technologies for meeting these needs in the context of a passively cooled ATLAST.

  8. Stereospecific analysis of loxoprofen in plasma by chiral column liquid chromatography with a circular dichroism-based detector.

    PubMed

    Kanazawa, Hideko; Tsubayashi, Akane; Nagata, Yoshiko; Matsushima, Yoshikazu; Mori, Chiharu; Kizu, Junko; Higaki, Megumu

    2002-03-01

    The chiral separation of loxoprofen was achieved on a chiral column with UV and circular dichroism (CD) detection. The good resolution of four loxoprofen stereoisomers was obtained. The column used for the chiral separation was Chiralcel OJ column (250 x 4.6 mm) using hexane-2-propanol-trifluoroacetic acid (95:5:0.1), as an eluent. The flow-rate was 1.0 ml/min and the detection was at 225 nm. In addition, CD and UV spectra were obtained by stopped flow scanning. The method allows the determination of the stereoisomers of loxoprofen in human plasma after the administration of therapeutic dose of the racemic drug, thus HPLC with CD detector is useful for the stereospecific determination of loxoprofen products in biological samples.

  9. A multispectral, high-speed, low-cost device in the UV-MWIR spectral range

    NASA Astrophysics Data System (ADS)

    Svensson, Thomas; Lindell, Roland; Carlsson, Leif

    2011-10-01

    This paper presents the design and performance of a multispectral, high-speed, low-cost device. It is composed of six separate single element detectors covering the spectral range from UV to MWIR. Due to the wide spectral ranges of the detectors, these are used in conjunction with spectral filters. The device is a tool to spectrally and temporally resolve large field of view angularly integrated signatures from very fast events and get a total amplitude measure. One application has been to determine the maximal amplitude signal in muzzle flashes. Since the pulse width of a muzzle flash is on the order of 1 ms, a sensor with a bandwidth significantly higher than 1000 Hz is needed to resolve the flash. Examples from experimental trials are given.

  10. Ambient temperature effects on broadband UV-B measurements using fluorescent phosphor (MgWO4)-based detectors

    NASA Technical Reports Server (NTRS)

    Dichter, Bronislaw K.; Beaubien, David J.; Beaubien, Arthur F.

    1994-01-01

    Results of field tests on a group of broadband UV-B pyranometers are presented. A brief description of the instrument is given. The effects of ambient temperature on thermally unregulated fluorescent phosphor (Robertson type) meters are presented and compared with the performance of thermally stabilized instruments. Means for correcting data from thermally unregulated instruments, where the prevailing ambient temperatures are known, are outlined.

  11. Channel Modelling and Performance of Non-Line-of-Sight Ultraviolet Scattering Communications

    DTIC Science & Technology

    2012-01-01

    Avalanche photodiode (APD) detectors are also rapidly being developed [6, 7]. These device advances have inspired recent research in LED-based short...response and path loss results for outdoor NLOS UV communication channels in Section 3. The impulse response modelling describes UV pulse broadening via...Both the impulse response and path loss are critical to communication system design and performance assessment. Although pulse broadening creates inter

  12. A Stability Indicating HPLC Method for the Determination of Fluvoxamine in Pharmaceutical Dosage Forms.

    PubMed

    Souri, Effat; Donyayi, Hassan; Khaniha, Reza Ahmad; Barazandeh Tehrani, Maliheh

    2015-01-01

    Fluvoxamine maleate is a selective serotonin reuptake inhibitor, which is used for the treatment of different types of depressive disorders. In the present study, a stability indicating HPLC method was developed and validated for the determination of fluvoxamine maleate. The chromatographic separation was carried out using a Nova-Pak CN column and a mixture of K2HPO4 50 mM (pH 7.0) and acetonitrile (60: 40, v/v) as the mobile phase. Target compounds were detected using a UV detector set at 235 nm. The developed method was linear over the concentration range of 1-80 μg/ml with acceptable precision (CV values < 2.0%) and accuracy (error values < 1.6%). The degradation studies showed that fluvoxamine maleate is relatively unstable under acidic, basic and oxidative conditions and also when exposed to UV radiation. On the other hand, the bulk powder of fluvoxamine maleate was relatively stable when exposed to visible light or heat. The proposed method was successfully applied for the determination of active ingredient of fluvoxamine dosage form without any interference from tablet excipients.

  13. Comparison of detection techniques for capillary electrophoresis analysis of gold nanoparticles.

    PubMed

    Matczuk, Magdalena; Aleksenko, Svetlana S; Matysik, Frank-Michael; Jarosz, Maciej; Timerbaev, Andrei R

    2015-05-01

    As metallic nanoparticles are growing in importance as analytes in CE, increases an interest in appropriate detection methods for their quantification in various samples. For gold nanoparticles (AuNPs), the most common UV detection poses intricacy of inadequate sensitivity that hinders the applicability of CE. With the objective of resolving this challenge, UV detection was compared with C(4) D and ICP-MS as alternative modes of detection for AuNPs. A C(4) D detector, applied under pressure-driven conditions, exhibited better sensitivity than a UV detector. However, C(4) D turned to be unsatisfactory to differentiate the signal of AuNPs at common CE conditions despite varying the nature of BGE and detection conditions. Due to intrinsic sensitivity and low background levels typical to Au, ICP-MS greatly surpasses UV detection. After optimization trials, CE-ICP-MS gained the LOD of AuNPs as low as 2 × 10(-15) M, as well as an excellent performance in terms of signal stability and linearity. Also importantly, the optimized BGE appears to be well matched to explore the behavior of AuNPs in biologically relevant systems. This was demonstrated by probing the interaction between AuNPs and the main blood-transporting protein, HSA. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. [Determination of sulpride in human plasma by high performance liquid chromatography].

    PubMed

    Yu, X; Luo, Z; Tang, J; Yu, P

    1997-11-01

    This paper describes a reliable method for the pharmacokinetic study of Sulpride in human plasma by reversed-phase high performance liquid chromatography. To compensate the loss of Sulpride during the extraction procedure we used an internal standard very similar in chemical structure and UV absorbance to those of Sulpride. The mobile phase was methanol-water-acetic acid (60:30:1) with a flow rate of 1.2 mL/min. A UV detector was used at 290 nm. The linear range was 5-100 mg/L and the detectable limit was 1.0 mg/L. The recovery and RSD were 97.95%-99.96% and 2.6%-5.1% respectively. The results showed that this method is a sensitive and accurate one which makes the pharmacokinetic study of Sulpride possible. If the concentration was too low to be detected by UV monitor, a fluorescence detector could be used with the excitation wavelength at 299 nm and emission at 342 nm. We analyzed the plasma samples from 30 day-treated psychotic patients and got the satisfactory results.

  15. Microwave irradiation-assisted deposition of Ga2O3 on III-nitrides for deep-UV opto-electronics

    NASA Astrophysics Data System (ADS)

    Jaiswal, Piyush; Ul Muazzam, Usman; Pratiyush, Anamika Singh; Mohan, Nagaboopathy; Raghavan, Srinivasan; Muralidharan, R.; Shivashankar, S. A.; Nath, Digbijoy N.

    2018-01-01

    We report on the deposition of Ga2O3 on III-nitride epi-layers using the microwave irradiation technique. We also report on the demonstration of a Ga2O3 device: a visible-blind, deep-UV detector, with a GaN-based heterostructure as the substrate. The film deposited in the solution medium, at <200 °C, using a metalorganic precursor, was nanocrystalline. XRD confirms that the as-deposited film, when annealed at high temperature, turns to polycrystalline β-Ga2O3. SEM shows the as-deposited film to be uniform, with a surface roughness of 4-5 nm, as revealed by AFM. Interdigitated metal-semiconductor-metal devices with Ni/Au contact exhibited a peak spectral response at 230 nm and a good visible rejection ratio. This demonstration of a deep-UV detector on the β-Ga2O3/III-nitride stack is expected to open up possibilities of functional and physical integration of β-Ga2O3 and GaN material families towards enabling next-generation high-performance devices by exciting band and heterostructure engineering.

  16. Study on aggregation behavior of low density lipoprotein in hen egg yolk plasma by asymmetrical flow field-flow fractionation coupled with multiple detectors.

    PubMed

    Dou, Haiyang; Magnusson, Emma; Choi, Jaeyeong; Duan, Fei; Nilsson, Lars; Lee, Seungho

    2016-02-01

    In this study, asymmetrical flow field-flow fractionation (AF4) coupled online with UV, multiangle light scattering (MALS), and fluorescence (FS) detectors (AF4-UV-MALS-FS) was employed for separation and characterization of egg yolk plasma. AF4 provided separation of three major components of the egg yolk plasma i.e. soluble proteins, low density lipoproteins (LDL) and their aggregates, based on their respective hydrodynamic sizes. Identification of LDL was confirmed by staining the sample with a fluorescent dye, Nile Red. The effect of carrier liquids on aggregation of LDL was investigated. Collected fractions of soluble proteins were characterized using sodium dodecylsulfate polyacrylamide gel electrophoresis (SDS-PAGE). Moreover, the effect of heat and enzymatic treatment on egg yolk plasma was investigated. The results suggest that enzymatic treatment with phospholipase A2 (PLA2) significantly enhances the heat stability of LDL. The results show that AF4-UV-MALS-FS is a powerful tool for the fractionation and characterization of egg yolk plasma components. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. In Situ Biodosimetric Experiment for Space Applications

    NASA Astrophysics Data System (ADS)

    Goldschmidt, Gergely; Kovaliczky, Éva; Szabó, József; Rontó, Györgyi; Bérces, Attila

    2012-06-01

    This paper presents the principles and application of DNA based biological UV dosimeters, as developed by Research Group for Biophysics (RGB). These dosimeters are used for assessing the biological hazard of living systems on the Earth's surface and in different waters (rivers, lakes, seas, etc.). The UV dosimetry system has also been used in the space. In dosimeters a bacterial virus, bacteriophage T7 and polycrystalline uracil thin layers have been used as biological detectors. On the Earth's surface the UV radiation induces dimer formation in phage T7 and in the uracil detector, which was evaluated by loss of viability of the phage particles and by the decrease of the characteristic optical density (OD) of uracil thin layers. Recently the development of human space activities has also increased the need to measure the biological effect of extraterrestrial solar radiation, too. The evaluation of the space samples occurred on ground, thus only the starting and the final state were taken into account. A new improved, automated method is presented below which makes data collection more efficient and also makes the dynamics of the process observable.

  18. Chlorophyll degradation in aqueous mediums induced by light and UV-B irradiation: An UHPLC-ESI-MS study

    NASA Astrophysics Data System (ADS)

    Petrović, Sanja; Zvezdanović, Jelena; Marković, Dejan

    2017-12-01

    Irreversible chlorophyll degradation induced by continuous white light illumination and UV-B irradiation in the aqueous mediums (with 10%, 30% and 50% of methanol) was investigated using the ultrahigh liquid chromatography coupled with diode array and electrospray ionization mass spectrometry detectors (UHPLC-DAD-ESIMS). The degradation was governed by energy input of photons: higher energy of UV-B irradiation induced faster chlorophyll degradation and accordingly faster products formation in comparison to the white light treatment. Main light- or/and UV-B-induced products of chlorophyll in the aqueous mediums were hydroxy-pheophytin a, pheophytin a and hydroxy-lactone-pheophytin a, accompanied with the corresponding epimers. Chlorophylls aggregation dominant in the aqueous medium with the highest methanol content (50%) play a protective role against the UV-B radiation and white light illumination.

  19. Plural-wavelength flame detector that discriminates between direct and reflected radiation

    NASA Technical Reports Server (NTRS)

    Hall, Gregory H. (Inventor); Barnes, Heidi L. (Inventor); Medelius, Pedro J. (Inventor); Simpson, Howard J. (Inventor); Smith, Harvey S. (Inventor)

    1997-01-01

    A flame detector employs a plurality of wavelength selective radiation detectors and a digital signal processor programmed to analyze each of the detector signals, and determine whether radiation is received directly from a small flame source that warrants generation of an alarm. The processor's algorithm employs a normalized cross-correlation analysis of the detector signals to discriminate between radiation received directly from a flame and radiation received from a reflection of a flame to insure that reflections will not trigger an alarm. In addition, the algorithm employs a Fast Fourier Transform (FFT) frequency spectrum analysis of one of the detector signals to discriminate between flames of different sizes. In a specific application, the detector incorporates two infrared (IR) detectors and one ultraviolet (UV) detector for discriminating between a directly sensed small hydrogen flame, and reflections from a large hydrogen flame. The signals generated by each of the detectors are sampled and digitized for analysis by the digital signal processor, preferably 250 times a second. A sliding time window of approximately 30 seconds of detector data is created using FIFO memories.

  20. Time-resolved optically stimulated luminescence of Al2O3:C for ion beam therapy dosimetry

    NASA Astrophysics Data System (ADS)

    Yukihara, Eduardo G.; Doull, Brandon A.; Ahmed, Md; Brons, Stephan; Tessonnier, Thomas; Jäkel, Oliver; Greilich, Steffen

    2015-09-01

    The objective of this study was to characterize the time-resolved (TR) optically stimulated luminescence (OSL) from Al2O3:C detectors and investigate methodologies to improve the accuracy of these detectors in ion beam therapy dosimetry, addressing the reduction in relative response to high linear energy transfer (LET) particles common to solid-state detectors. Al2O3:C OSL detectors (OSLDs) were exposed to proton, 4He, 12C and 16O beams in 22 particle/energy combinations and read using a custom-built TR-OSL reader. The OSL response {{r}\\text{OSL}} , relative to 60Co gamma dose to water, and the ratio between the UV and blue OSL emission bands of Al2O3:C (UV/blue ratio) were determined as a function of the LET. Monte-Carlo simulations with the multi-purpose interaction and transport code FLUKA were used to estimate the absorbed doses and particle energy spectra in the different irradiation conditions. The OSL responses {{r}\\text{OSL}} varied from 0.980 (0.73 keV μm-1) to 0.288 (120.8 keV μm-1). The OSL UV/blue ratio varied by a factor of two in the investigated LET range, but the variation for 12C beams was only 11%. OSLDs were also irradiated at different depths of carbon ion spread-out Bragg peaks (SOBPs), where it was shown that doses could be obtained with an accuracy of  ±2.0% at the entrance channel and within the SOBP using correction factors calculated based on the OSL responses obtained in this study. The UV/blue ratio did not allow accurate estimation of the dose-averaged LET for 12C SOBPs, although the values obtained can be explained with the data obtained in this study and the additional information provided by the Monte-Carlo simulations. The results demonstrate that accurate OSLD dosimetry can be performed in ion beam therapy using appropriate corrections for the OSL response.

  1. A Single Element Charge Injection Device as a Spectroscopic Detector.

    DTIC Science & Technology

    1987-05-26

    major approaches to designing a AES spectrometer exist, one involving simultaneous multiwavelength monitoring with multiple detectors or an imaging...are below 1%. (2) Limited Spectral Range. While it is possible to construct photocathodes optimized for maximum response within nearly any UV -visible...reflectance paint. A ring of five light emitting diodes ( LEDs ) inside the cylinder is used as a light source, with the duration of illumination

  2. Enhancing UV photoconductivity of ZnO nanobelt by polyacrylonitrile functionalization

    NASA Astrophysics Data System (ADS)

    He, J. H.; Lin, Yen H.; McConney, Michael E.; Tsukruk, Vladimir V.; Wang, Zhong L.; Bao, Gang

    2007-10-01

    UV photodetector fabricated using a single ZnO nanobelt (NB) has shown a photoresponse enhancement up to 750 times higher than that of a bare ZnO NB after coating with ˜20nm plasma polymerized acrylonitrile (PP-AN) nanoscale film. The mechanism for this colossal photoconductivity is suggested as a consequence of the efficient exciton dissociation under UV illumination due to enhanced electron transfer from valence band of ZnO NB to the PP-AN and then back to the conduction band of ZnO. This process has demonstrated an easy and effective method for improving the performance of the nanowire/NB-based devices, possibly leading to supersensitive UV detector for applications in imaging, photosensing, and intrachip optical interconnects.

  3. [Study on HPLC fingerprint of Alpinia officinarum].

    PubMed

    Deng, Yi-Feng; Feng, Li-Na; Luo, Hui

    2011-09-01

    To establish the chromatography fingerprint of Alpinia officinarum by HPLC. An optimum HPLC conditions which were obtained under the assessment of LC-MS were as follows: Shim-pack VP-ODS column (2.0 mm x 250 mm, 5 microm), 0.1% HAc aqueous solution as phase A, 15% Acetonitrile: 40% Methanol: 45% Tetrafuran as phase B, the flow rate was 0.20 mL/min, column temperature was 35 degrees C and UV detector was set at 280 nm. The HPLC fingerprint of Alpinia officinarum was established, the consensus 10 peaks and their relative retention times along with the ranges of relative area were determined. The method is reliable and stable and can be used for the quality control and identification of Alpinia officinarum.

  4. Application of portable online LED UV fluorescence sensor to predict the degradation of dissolved organic matter and trace organic contaminants during ozonation.

    PubMed

    Li, Wen-Tao; Majewsky, Marius; Abbt-Braun, Gudrun; Horn, Harald; Jin, Jing; Li, Qiang; Zhou, Qing; Li, Ai-Min

    2016-09-15

    This work aims to correlate signals of LED UV/fluorescence sensor with the degradation of dissolved organic matter (DOM) and trace-level organic contaminants (TOrCs) during ozonation process. Six sets of bench-scale ozonation kinetic experiments incorporated with three different water matrices and 14 TOrCs of different reactivity (group I ∼ V) were conducted. Calibrated by tryptophan and humic substances standards and verified by the lab benchtop spectroscopy, the newly developed portable/online LED sensor, which measures the UV280 absorbance, protein-like and humic-like fluorescence simultaneously, was feasible to monitor chromophores and fluorophores with good sensitivity and accuracy. The liquid chromatography with organic carbon detector combined with 2D synchronous correlation analysis further demonstrated how the DOM components of large molecular weight were transformed into small moieties as a function of the decrease of humic-like fluorescence. For TOrCs, their removal rates were well correlated with the decrease of the LED UV/fluorescence signals, and their elimination patterns were mainly determined by their reactivity with O3 and hydroxyl radicals. At approximately 50% reduction of humic-like fluorescence almost complete oxidation of TOrCs of group I and II was reached, a similar removal percentage (25-75%) of TOrCs of group III and IV, and a poor removal percentage (<25%) of group V. This study might contribute to the smart control of advanced oxidation processes for the water and wastewater treatment in the future. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Initial observations of Jupiter's aurora from Juno's Ultraviolet Spectrograph (Juno-UVS)

    NASA Astrophysics Data System (ADS)

    Gladstone, R.; Versteeg, M.; Greathouse, T.; Hue, V.; Davis, M. W.; Gerard, J. C. M. C.; Grodent, D. C.; Bonfond, B.; Bolton, S. J.; Connerney, J. E. P.; Levin, S.; Bagenal, F.; Mauk, B.; Kurth, W. S.; McComas, D. J.; Valek, P. W.

    2016-12-01

    Juno-UVS is an imaging spectrograph with a bandpass of 70<λ<205 nm. This wavelength range includes important far-ultraviolet (FUV) emissions from the H2 bands and the H Lyman series which are produced in Jupiter's auroras, and also the absorption signatures of aurorally-produced hydrocarbons. The Juno-UVS instrument telescope has a 4x4 cm2 input aperture and uses an off-axis parabolic primary mirror. A flat scan mirror situated near the entrance of the telescope is used to observe at up to ±30° perpendicular to the Juno spin plane. The light is focused onto the spectrograph entrance slit, which has a "dog-bone" shape, with three sections of 2.55°x0.2°, 2.0°x0.025°, and 2.55°x0.2° (as projected onto the sky). Light entering the slit is dispersed by a toroidal grating which focuses FUV light onto a curved microchannel plate (MCP) cross delay line (XDL) detector with a solar blind UV-sensitive CsI photocathode. The two mirrors and the grating are coated with MgF2 to improve FUV reflectivity. Tantalum surrounds the spectrograph assembly to shield the detector and its electronics from high-energy electrons. All other electronics are located in Juno's spacecraft vault, including redundant low-voltage and high-voltage power supplies, command and data handling electronics, heater/actuator electronics, scan mirror electronics, and event processing electronics. The purpose of Juno-UVS is to remotely sense Jupiter's auroral morphology and brightness to provide context for in situ measurements by Juno's particle instruments. Here we present the first near-Jupiter results from the UVS instrument following measurements made during PJ1, Juno's first perijove pass with its instruments powered on and taking data.

  6. A highly selective nanocomposite based on MIP for curcumin trace levels quantification in food samples and human plasma following optimization by central composite design.

    PubMed

    Bahrani, Sonia; Ghaedi, Mehrorang; Khoshnood Mansoorkhani, Mohammad Javad; Ostovan, Abbas

    2017-01-01

    A selective and rapid method was developed for quantification of curcumin in human plasma and food samples using molecularly imprinted magnetic multiwalled carbon nanotubes (MMWCNTs) which was characterized with EDX and FESEM. The role of sorbent mass, volume of eluent and sonication time on response in solid phase microextraction procedure were optimized by central composite design (CCD) combined with response surface methodology (RSM) using Statistica. Preliminary experiments reveal that among different solvents, methanol:dimethyl sulfoxide (4:1V/V) led to efficient and quantitative elution of analyte. A reversed-phase high performance liquid chromatographic technique with UV detection (HPLC-UV) was applied for detection of curcumin content. The assay procedure involves chromatographic separation on analytical Nucleosil C18 column (250×4.6mm I.D., 5μm particle size) at ambient temperature with acetonitrile-water adjusted at pH=4.0 (20:80, v/v) as mobile phase at flow rate of 1.0mLmin -1 , while UV detector was set at 420nm. Under optimized conditions, the method demonstrated linear calibration curve with good detection limit (0.028ngmL -1 ) and R 2 =0.9983. The proposed method was successfully applied to biological fluid and food samples including ginger powder, curry powder, and turmeric powder. Copyright © 2016. Published by Elsevier B.V.

  7. Juno Ultraviolet Spectrograph (Juno-UVS) Observations of Jupiter during Approach

    NASA Astrophysics Data System (ADS)

    Gladstone, Randy; Versteeg, Maarten; Greathouse, Thomas K.; Hue, Vincent; Davis, Michael; Gerard, Jean-Claude; Grodent, Denis; Bonfond, Bertrand

    2016-10-01

    We present the initial results from Juno Ultraviolet Spectrograph (Juno-UVS) observations of Jupiter obtained during approach in June 2016. Juno-UVS is an imaging spectrograph with a bandpass of 70<λ<205 nm. This wavelength range includes all important ultraviolet (UV) emissions from the H2 bands and the H Lyman series which are produced in Jupiter's auroras, and also the absorption signatures of aurorally-produced hydrocarbons. The Juno-UVS instrument telescope has a 4 x 4 cm2 input aperture and uses an off-axis parabolic primary mirror. A flat scan mirror situated near the entrance of the telescope is used to observe at up to ±30° perpendicular to the Juno spin plane. The light is focused onto the spectrograph entrance slit, which has a "dog-bone" shape 7.2° long, in three sections of 0.2°, 0.025°, and 0.2° width (as projected onto the sky). Light entering the slit is dispersed by a toroidal grating which focuses UV light onto a curved microchannel plate (MCP) cross delay line (XDL) detector with a solar blind UV-sensitive CsI photocathode. Tantalum surrounds the spectrograph assembly to shield the detector and its electronics from high-energy electrons. All other electronics are located in Juno's spacecraft vault, including redundant low-voltage and high-voltage power supplies, command and data handling electronics, heater/actuator electronics, scan mirror electronics, and event processing electronics. The purpose of Juno-UVS is to remotely sense Jupiter's auroral morphology and brightness to provide context for in situ measurements by Juno's particle instruments. Prior to Jupiter Orbit Insertion (JOI) on July 5, Juno approach observations provide a rare opportunity to correlate local solar wind conditions with Jovian auroral emissions. Some of Jupiter's auroral emissions (e.g., polar emissions) may be controlled or at least affected by the solar wind. Here we compare synoptic Juno-UVS observations of Jupiter's auroral emissions (~40 minutes per hour, acquired during 2016 June 3-30) with in situ solar wind observations, as well as related Jupiter observations obtained from Earth.

  8. Evaluation of Machine Learning Algorithms for Classification of Primary Biological Aerosol using a new UV-LIF spectrometer

    NASA Astrophysics Data System (ADS)

    Ruske, S. T.; Topping, D. O.; Foot, V. E.; Kaye, P. H.; Stanley, W. R.; Morse, A. P.; Crawford, I.; Gallagher, M. W.

    2016-12-01

    Characterisation of bio-aerosols has important implications within Environment and Public Health sectors. Recent developments in Ultra-Violet Light Induced Fluorescence (UV-LIF) detectors such as the Wideband Integrated bio-aerosol Spectrometer (WIBS) and the newly introduced Multiparameter bio-aerosol Spectrometer (MBS) has allowed for the real time collection of fluorescence, size and morphology measurements for the purpose of discriminating between bacteria, fungal Spores and pollen. This new generation of instruments has enabled ever-larger data sets to be compiled with the aim of studying more complex environments, yet the algorithms used for specie classification remain largely invalidated. It is therefore imperative that we validate the performance of different algorithms that can be used for the task of classification, which is the focus of this study. For unsupervised learning we test Hierarchical Agglomerative Clustering with various different linkages. For supervised learning, ten methods were tested; including decision trees, ensemble methods: Random Forests, Gradient Boosting and AdaBoost; two implementations for support vector machines: libsvm and liblinear; Gaussian methods: Gaussian naïve Bayesian, quadratic and linear discriminant analysis and finally the k-nearest neighbours algorithm. The methods were applied to two different data sets measured using a new Multiparameter bio-aerosol Spectrometer. We find that clustering, in general, performs slightly worse than the supervised learning methods correctly classifying, at best, only 72.7 and 91.1 percent for the two data sets. For supervised learning the gradient boosting algorithm was found to be the most effective, on average correctly classifying 88.1 and 97.8 percent of the testing data respectively across the two data sets. We discuss the wider relevance of these results with regards to challenging existing classification in real-world environments.

  9. CALDER: Cryogenic light detectors for background-free searches

    NASA Astrophysics Data System (ADS)

    Di Domizio, S.; Bellini, F.; Cardani, L.; Casali, N.; Castellano, M. G.; Colantoni, I.; Cosmelli, C.; Cruciani, A.; D'Addabbo, A.; Martinez, M.; Minutolo, L.; Tomei, C.; Vignati, M.

    2018-01-01

    CALDER is a R&D project for the development of cryogenic light detectors with an active surface of 5x5cm2 and an energy resolution of 20 eV RMS for visible and UV photons. These devices can enhance the sensitivity of next generation large mass bolometric detectors for rare event searches, providing an active background rejection method based on particle discrimination. A CALDER detector is composed by a large area Si absorber substrate with superconducting kinetic inductance detectors (KIDs) deposited on it. The substrate converts the incoming light into athermal phonons, that are then sensed by the KIDs. KID technology combine fabrication simplicity with natural attitude to frequency-domain multiplexing, making it an ideal candidate for a large scale bolometric experiments. We will give an overview of the CALDER project and show the performances obtained with prototype detectors both in terms of energy resolution and efficiency.

  10. Quick, easy, cheap, effective, rugged, and safe sample preparation approach for pesticide residue analysis using traditional detectors in chromatography: A review.

    PubMed

    Rahman, Md Musfiqur; Abd El-Aty, A M; Kim, Sung-Woo; Shin, Sung Chul; Shin, Ho-Chul; Shim, Jae-Han

    2017-01-01

    In pesticide residue analysis, relatively low-sensitivity traditional detectors, such as UV, diode array, electron-capture, flame photometric, and nitrogen-phosphorus detectors, have been used following classical sample preparation (liquid-liquid extraction and open glass column cleanup); however, the extraction method is laborious, time-consuming, and requires large volumes of toxic organic solvents. A quick, easy, cheap, effective, rugged, and safe method was introduced in 2003 and coupled with selective and sensitive mass detectors to overcome the aforementioned drawbacks. Compared to traditional detectors, mass spectrometers are still far more expensive and not available in most modestly equipped laboratories, owing to maintenance and cost-related issues. Even available, traditional detectors are still being used for analysis of residues in agricultural commodities. It is widely known that the quick, easy, cheap, effective, rugged, and safe method is incompatible with conventional detectors owing to matrix complexity and low sensitivity. Therefore, modifications using column/cartridge-based solid-phase extraction instead of dispersive solid-phase extraction for cleanup have been applied in most cases to compensate and enable the adaptation of the extraction method to conventional detectors. In gas chromatography, the matrix enhancement effect of some analytes has been observed, which lowers the limit of detection and, therefore, enables gas chromatography to be compatible with the quick, easy, cheap, effective, rugged, and safe extraction method. For liquid chromatography with a UV detector, a combination of column/cartridge-based solid-phase extraction and dispersive solid-phase extraction was found to reduce the matrix interference and increase the sensitivity. A suitable double-layer column/cartridge-based solid-phase extraction might be the perfect solution, instead of a time-consuming combination of column/cartridge-based solid-phase extraction and dispersive solid-phase extraction. Therefore, replacing dispersive solid-phase extraction with column/cartridge-based solid-phase extraction in the cleanup step can make the quick, easy, cheap, effective, rugged, and safe extraction method compatible with traditional detectors for more sensitive, effective, and green analysis. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. UV astronomy throughout the ages: a historical perspective

    NASA Astrophysics Data System (ADS)

    Linsky, Jeffrey L.

    2018-05-01

    Astronomers have long recognized the critical need for ultraviolet imaging, photometry and spectroscopy of stars, planets, and galaxies, but this need could not be satisfied without access to space and the development of efficient instrumentation. When UV measurements became feasible, first with rockets and then with satellites, major discoveries came rapidly. It is true in the UV spectral region as in all others, that significant increases in sensitivity, spectral resolution, and time domain coverage have led to significant new understanding of astrophysical phenomena. I will describe a selection of these discoveries made in each of three eras: (1) the early history of rocket instrumentation and Copernicus, the first UV satellite, (2) the discovery phase pioneered by the IUE, FUSE and EUVE satellites, and (3) the full flowering of UV astronomy with the successful operation of HST and its many instruments. I will also mention a few areas where future UV instrumentation could lead to new discoveries. This review concentrates on developments in stellar and interstellar UV spectroscopy; the major discoveries in galactic, extragalactic, and solar system research are beyond the scope of this review. The important topic of UV technologies and detectors, which enable the remarkable advances in UV astronomy are also not included in this review.

  12. Testing Lorentz Invariance with Neutrinos from Ultrahigh Energy Cosmic Ray Interactions

    NASA Technical Reports Server (NTRS)

    Scully, Sean T.; Stecker, Floyd W.

    2010-01-01

    We have previously shown that a very small amount of Lorentz invariance violation (UV), which suppresses photomeson interactions of ultrahigh energy cosmic rays (UHECRs) with cosmic background radiation (CBR) photons, can produce a spectrum of cosmic rays that is consistent with that currently observed by the Pierre Auger Observatory (PAO) and HiRes experiments. Here, we calculate the corresponding flux of high energy neutrinos generated by the propagation of UHECR protons through the CBR in the presence of UV. We find that UV produces a reduction in the flux of the highest energy neutrinos and a reduction in the energy of the peak of the neutrino energy flux spectrum, both depending on the strength of the UV. Thus, observations of the UHE neutrino spectrum provide a clear test for the existence and amount of UV at the highest energies. We further discuss the ability of current and future proposed detectors make such observations.

  13. Development and Validation of a Simultaneous RP-HPLCUV/DAD Method for Determination of Polyphenols in Gels Containing S. terebinthifolius Raddi (Anacardiaceae)

    PubMed Central

    Carvalho, Melina G.; Aragão, Cícero F. S; Raffin, Fernanda N.; de L. Moura, Túlio F. A.

    2017-01-01

    Topical gels containing extracts of Schinus terebinthifolius have been used to treat bacterial vaginosis. It has been reported that this species has antimicrobial, anti-inflammatory and anti-ulcerogenic properties, which can be attributed to the presence of phenolic compounds. In this work, a sensitive and selective reversed-phase HPLC-UV/DAD method for the simultaneous assay of six polyphenols that could be present in S. terebinthifolius was developed. The method was shown to be accurate and precise. Peak purity and similarity index both exceeded 0.99. Calibration curves were linear over the concentration range studied, with correlation coefficients between 0.9931 and 0.9974. This method was used to determine the polyphenol content of a hydroalcoholic extract and pharmacy-compounded vaginal gel. Although the method is useful to assess the 6 phenolic compounds, some compounds could not be detected in the products. SUMMARY A sensitive, selective, accurate and precise reversed-phase HPLC-UV/DAD method for the simultaneous assay of six polyphenols in S. terebinthifolius Raddi Abbreviations used: RP-HPLC-UV/DAD: Reverse Phase High Performance Liquid Chromatograph with Ultraviolet and Diode Array Detector, HPLC: High Performance Liquid Chromatograph, HPLC-UV: High Performance Liquid Chromatograph with Ultraviolet Detector, ANVISA: Brazilian National Health Surveillance Agency, LOD: Limit of detection, LOQ: Limit of quantitation PMID:28539726

  14. Sources and measurement of ultraviolet radiation.

    PubMed

    Diffey, Brian L

    2002-09-01

    Ultraviolet (UV) radiation is part of the electromagnetic spectrum. The biological effects of UV radiation vary enormously with wavelength and for this reason the UV spectrum is further subdivided into three regions: UVA, UVB, and UVC. Quantities of UV radiation are expressed using radiometric terminology. A particularly important term in clinical photobiology is the standard erythema dose (SED), which is a measure of the erythemal effectiveness of a UV exposure. UV radiation is produced either by heating a body to an incandescent temperature, as is the case with solar UV, or by passing an electric current through a gas, usually vaporized mercury. The latter process is the mechanism whereby UV radiation is produced artificially. Both the quality (spectrum) and quantity (intensity) of terrestrial UV radiation vary with factors including the elevation of the sun above the horizon and absorption and scattering by molecules in the atmosphere, notably ozone, and by clouds. For many experimental studies in photobiology it is simply not practicable to use natural sunlight and so artificial sources of UV radiation designed to simulate the UV component of sunlight are employed; these are based on either optically filtered xenon arc lamps or fluorescent lamps. The complete way to characterize an UV source is by spectroradiometry, although for most practical purposes a detector optically filtered to respond to a limited portion of the UV spectrum normally suffices.

  15. NARSTO PAC2001 CONVAIR PM OZONE MET DATA

    Atmospheric Science Data Center

    2018-04-09

    NARSTO PAC2001 CONVAIR PM OZONE MET DATA Project Title:  NARSTO Discipline:  Tropospheric Composition Field Campaigns Aerosols ... Temperature Probe Humidity Probe Wind Sensor UV Ozone Detector Optical Counter Location:  Lower Fraser ...

  16. Thermo-optical Characterization of Photothermal Optical Phase Shift Detection in Extended-Nano Channels and UV Detection of Biomolecules.

    PubMed

    Shimizu, Hisashi; Miyawaki, Naoya; Asano, Yoshihiro; Mawatari, Kazuma; Kitamori, Takehiko

    2017-06-06

    The expansion of microfluidics research to nanofluidics requires absolutely sensitive and universal detection methods. Photothermal detection, which utilizes optical absorption and nonradiative relaxation, is promising for the sensitive detection of nonlabeled biomolecules in nanofluidic channels. We have previously developed a photothermal optical phase shift (POPS) detection method to detect nonfluorescent molecules sensitively, while a rapid decrease of the sensitivity in nanochannels and the introduction of an ultraviolet (UV) excitation system were issues to be addressed. In the present study, our primary aim is to characterize the POPS signal in terms of the thermo-optical properties and quantitatively evaluate the causes for the decrease in sensitivity. The UV excitation system is then introduced into the POPS detector to realize the sensitive detection of nonlabeled biomolecules. The UV-POPS detection system is designed and constructed from scratch based on a symmetric microscope. The results of simulations and experiments reveal that the sensitivity decreases due to a reduction of the detection volume, dissipation of the heat, and cancellation of the changes in the refractive indices. Finally, determination of the concentration of a nonlabeled protein (bovine serum albumin) is performed in a very thin 900 nm deep nanochannel. As a result, the limit of detection (LOD) is 2.3 μM (600 molecules in the 440 attoliter detection volume), which is as low as that previously obtained for our visible POPS detector. UV-POPS detection is thus expected be a powerful technique for the study of biomolecules, including DNAs and proteins confined in nanofluidic channels.

  17. UV spectroscopy with the CETUS multi-object spectrometer

    NASA Astrophysics Data System (ADS)

    Kendrick, Stephen E.; Woodruff, Robert; Hull, Anthony; Heap, Sara; Kutyrev, Alexander; Purves, Lloyd; Danchi, William

    2018-01-01

    The ultraviolet multi-object spectrograph (MOS) for the Cosmic Evolution Through UV Spectroscopy (CETUS) concept is a slit-based instrument allowing multiple simultaneous observations over a wide field of view. The UV MOS will be able to target up to 100 objects at a time without the issues of confusion with nearby sources or unwanted background like zodiacal stray light. The multiplexing will allow over 100,000 galaxies to be observed over a typical mission lifetime which greatly enhances the scientific yield. The MOS utilizes a next-generation micro-shutter array, an efficient aspheric Offner-like spectrometer design with a convex grating, and nanotube light traps for suppressing unwanted wavelengths. The optical coatings are also designed for optimizing the UV throughput while minimizing out-of-band signal at the detector.

  18. Multiplexing in astrophysics with a UV multi-object spectrometer on CETUS, a probe-class mission study

    NASA Astrophysics Data System (ADS)

    Kendrick, Stephen E.; Woodruff, Robert A.; Hull, Tony; Heap, Sara R.; Kutyrev, Alexander; Danchi, William; Purves, Lloyd

    2017-09-01

    The ultraviolet multi-object spectrograph (MOS) for the Cosmic Evolution Through UV Spectroscopy (CETUS) concept1,2 is a slit-based instrument allowing multiple simultaneous observations over a wide field of view. It utilizes a next-generation micro-shutter array, an efficient aspheric Offner spectrometer design with a convex grating, and carbon nanotube light traps for suppressing unwanted wavelengths. The optical coatings are also designed to optimize the UV throughput while minimizing out-of-band signal at the detector. The UV MOS will be able to target up to 100 objects at a time without the issues of confusion with nearby sources or unwanted background like zodiacal stray light. With this multiplexing, the scientific yield of both Probe and Great Observatories will be greatly enhanced.

  19. Accurate measurement of the first excited nuclear state in 235U

    NASA Astrophysics Data System (ADS)

    Ponce, F.; Swanberg, E.; Burke, J.; Henderson, R.; Friedrich, S.

    2018-05-01

    We have used superconducting high-resolution radiation detectors to measure the energy level of metastable Um235 as 76.737 ± 0.018 eV. The Um235 isomer is created from the α decay of 239Pu and embedded directly into the detector. When the Um235 subsequently decays, the energy is fully contained within the detector and is independent of the decay mode or the chemical state of the uranium. The detector is calibrated using an energy comb from a pulsed UV laser. A comparable measurement of the metastable Thm229 nucleus would enable a laser search for the exact transition energy in 229Th-Thm229 as a step towards developing the first ever nuclear (baryonic) clock.

  20. Environmentally evaluated HPLC-ELSD method to monitor enzymatic synthesis of a non-ionic surfactant.

    PubMed

    Gaber, Yasser; Akerman, Cecilia Orellana; Hatti-Kaul, Rajni

    2014-01-01

    N-Lauroyl-N-methylglucamide is a biodegradable surfactant derived from renewable resources. In an earlier study, we presented an enzymatic solvent-free method for synthesis of this compound. In the present report, the HPLC method developed to follow the reaction between lauric acid/methyl laurate and N-methyl glucamine (MEG) and its environmental assessment are described. Use of ultraviolet (UV) absorption or refractive index (RI) detectors did not allow the detection of N-methyl glucamine (MEG). With Evaporative light scattering detector ELSD, it was possible to apply a gradient elution, and detect MEG with a limit of detection, LOD = 0.12 μg. A good separation of the peaks: MEG, lauric acid, product (amide) and by-product (amide-ester) was achieved with the gradient program with a run time of 40 min. The setting of ELSD detector was optimized using methyl laurate as the analyte. LC-MS/MS was used to confirm the amide and amide-ester peaks. We evaluated the greenness of the developed method using the freely available software HPLC-Environmental Assessment Tool (HPLC-EAT) and the method got a scoring of 73 HPLC-EAT units, implying that the analytical procedure was more environmentally benign compared to some other methods reported in literature whose HPLC-EAT values scored up to 182. Use of ELSD detector allowed the detection and quantification of the substrates and the reaction products of enzymatic synthesis of the surfactant, N-lauroyl-N-methylglucamide. The developed HPLC method has acceptable environmental profile based on HPLC-EAT evaluation.

  1. Environmentally evaluated HPLC-ELSD method to monitor enzymatic synthesis of a non-ionic surfactant

    PubMed Central

    2014-01-01

    Background N-Lauroyl-N-methylglucamide is a biodegradable surfactant derived from renewable resources. In an earlier study, we presented an enzymatic solvent-free method for synthesis of this compound. In the present report, the HPLC method developed to follow the reaction between lauric acid/methyl laurate and N-methyl glucamine (MEG) and its environmental assessment are described. Results Use of ultraviolet (UV) absorption or refractive index (RI) detectors did not allow the detection of N-methyl glucamine (MEG). With Evaporative light scattering detector ELSD, it was possible to apply a gradient elution, and detect MEG with a limit of detection, LOD = 0.12 μg. A good separation of the peaks: MEG, lauric acid, product (amide) and by-product (amide-ester) was achieved with the gradient program with a run time of 40 min. The setting of ELSD detector was optimized using methyl laurate as the analyte. LC-MS/MS was used to confirm the amide and amide-ester peaks. We evaluated the greenness of the developed method using the freely available software HPLC-Environmental Assessment Tool (HPLC-EAT) and the method got a scoring of 73 HPLC-EAT units, implying that the analytical procedure was more environmentally benign compared to some other methods reported in literature whose HPLC-EAT values scored up to 182. Conclusion Use of ELSD detector allowed the detection and quantification of the substrates and the reaction products of enzymatic synthesis of the surfactant, N-lauroyl-N-methylglucamide. The developed HPLC method has acceptable environmental profile based on HPLC-EAT evaluation. PMID:24914404

  2. Broadband radiometric LED measurements

    NASA Astrophysics Data System (ADS)

    Eppeldauer, G. P.; Cooksey, C. C.; Yoon, H. W.; Hanssen, L. M.; Podobedov, V. B.; Vest, R. E.; Arp, U.; Miller, C. C.

    2016-09-01

    At present, broadband radiometric LED measurements with uniform and low-uncertainty results are not available. Currently, either complicated and expensive spectral radiometric measurements or broadband photometric LED measurements are used. The broadband photometric measurements are based on the CIE standardized V(λ) function, which cannot be used in the UV range and leads to large errors when blue or red LEDs are measured in its wings, where the realization is always poor. Reference irradiance meters with spectrally constant response and high-intensity LED irradiance sources were developed here to implement the previously suggested broadband radiometric LED measurement procedure [1, 2]. Using a detector with spectrally constant response, the broadband radiometric quantities of any LEDs or LED groups can be simply measured with low uncertainty without using any source standard. The spectral flatness of filtered-Si detectors and low-noise pyroelectric radiometers are compared. Examples are given for integrated irradiance measurement of UV and blue LED sources using the here introduced reference (standard) pyroelectric irradiance meters. For validation, the broadband measured integrated irradiance of several LED-365 sources were compared with the spectrally determined integrated irradiance derived from an FEL spectral irradiance lamp-standard. Integrated responsivity transfer from the reference irradiance meter to transfer standard and field UV irradiance meters is discussed.

  3. Quantitation of polymethoxylated flavones in orange juice by high-performance liquid chromatography.

    PubMed

    Rouseff, R L; Ting, S V

    1979-08-01

    A quantitative high-performance liquid chromatographic (HPLC) procedure for the determination of the five major polymethoxylated flavones (PMFs) in orange juice has been developed. It employs a unique ternary solvent system with coupled UV-fluorescence detection. The dual detectors were employed to determine the presence of interfering substances and served as a cross check on quantitation. Stop flow UV and fluorescence scanning was used to identify peaks and determine the presence of impurities. Although all five citrus PMFs fluoresce, some HPLC fluorescence peaks were too small to be of much practical use. All five citrus PMFs could be quantitated satisfactorily with the fixed wavelength UV (313 nm) detector. The HPLC procedure has been used to evaluate each step in the preparation. The optimum extracting solvent was selected and one time consuming step was eliminated, as it was found to be unnecessary. HPLC values for nobiletin and sinensetin are in good agreement with the thin-layer chromatographic (TLC) values in the literature. HPLC values for the other three flavones were considerably lower than those reported in the literature. The HPLC procedure is considerably faster than the TLC procedure with equal or superior precision and accuracy.

  4. Liquid Chromatographic Analysis of Nitrocellulose-Base Propellants

    DTIC Science & Technology

    1983-03-28

    18 radial PkC column using 10 micron silica coated with octadecyl silane. The detector was a LC 85 variable wavelength UV detector from Perkin-Elmer...Snyder, L. R. J Chrom Scd i6, (1978), 223. i •2 Glatch, J. L., Kirkland, J. J., Squire, K. M., and Miner, J. M.; J. Chromatgography, 199, (1980), 57. 4...assuming non retained peaks elute at 1 minute). This produces 3 solvents of approximately the same strengths bnt greatly differing selectivities. Once

  5. SUPPLEMENTARY COMPARISON: APMP.PR-S1 comparison of irradiance responsivity of UVA detectors

    NASA Astrophysics Data System (ADS)

    Xu, Gan; Huang, Xuebo; Liu, Yuanjie

    2007-01-01

    APMP.PR-S1, a supplementary comparison of irradiance responsivity of UVA detectors, was carried out among seven national metrology institutes piloted by SPRING Singapore from 2003 to 2005. Two quantities, the narrow band UV (365 nm ± 5 nm) irradiance responsivity and the broad band UVA (315 nm-400 nm) irradiance responsivity of the transfer detectors, have been compared. Commercial UV source (medium pressure mercury short arc lamp) and UVA detectors were used as transfer standards in the comparison. Measurement results from participants were reported and their uncertainties associated with the comparison were analysed in this report. The method of weighted mean with cut-off was used to calculate the comparison reference values. The results from most participating labs lie within ±5% against the comparison reference values with a few exceptions. The degree of agreement of the comparison depends not only on the base scales of spectral responsivity and spectral irradiance of a laboratory, but also equally importantly on the method used for the measurement. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  6. NARSTO PAC2001 CESSNA VOC PM OZONE MET DATA

    Atmospheric Science Data Center

    2018-04-09

    NARSTO PAC2001 CESSNA VOC PM OZONE MET DATA Project Title:  NARSTO Discipline:  Tropospheric Composition Field Campaigns Aerosols ... Temperature Probe Humidity Probe Wind Sensor UV Ozone Detector Optical Counter GC Location:  Lower Fraser ...

  7. Transmission of light in deep sea water at the site of the ANTARES neutrino telescope

    NASA Astrophysics Data System (ADS)

    ANTARES Collaboration; Aguilar, J. A.; Albert, A.; Amram, P.; Anghinolfi, M.; Anton, G.; Anvar, S.; Ardellier-Desages, F. E.; Aslanides, E.; Aubert, J.-J.; Azoulay, R.; Bailey, D.; Basa, S.; Battaglieri, M.; Becherini, Y.; Bellotti, R.; Beltramelli, J.; Bertin, V.; Billault, M.; Blaes, R.; Blanc, F.; Bland, R. W.; de Botton, N.; Boulesteix, J.; Bouwhuis, M. C.; Brooks, C. B.; Bradbury, S. M.; Bruijn, R.; Brunner, J.; Bugeon, F.; Burgio, G. F.; Cafagna, F.; Calzas, A.; Caponetto, L.; Carmona, E.; Carr, J.; Cartwright, S. L.; Cecchini, S.; Charvis, P.; Circella, M.; Colnard, C.; Compère, C.; Croquette, J.; Cooper, S.; Coyle, P.; Cuneo, S.; Damy, G.; van Dantzig, R.; Deschamps, A.; de Marzo, C.; Destelle, J.-J.; de Vita, R.; Dinkelspiler, B.; Dispau, G.; Drougou, J.-F.; Druillole, F.; Engelen, J.; Favard, S.; Feinstein, F.; Ferry, S.; Festy, D.; Fopma, J.; Fuda, J.-L.; Gallone, J.-M.; Giacomelli, G.; Girard, N.; Goret, P.; Gournay, J.-F.; Hallewell, G.; Hartmann, B.; Heijboer, A.; Hello, Y.; Hernández-Rey, J. J.; Herrouin, G.; Hößl, J.; Hoffmann, C.; Hubbard, J. R.; Jaquet, M.; de Jong, M.; Jouvenot, F.; Kappes, A.; Karg, T.; Karkar, S.; Karolak, M.; Katz, U.; Keller, P.; Kooijman, P.; Korolkova, E. V.; Kouchner, A.; Kretschmer, W.; Kudryavtsev, V. A.; Lafoux, H.; Lagier, P.; Lamare, P.; Languillat, J.-C.; Laubier, L.; Legou, T.; Le Guen, Y.; Le Provost, H.; Le van Suu, A.; Lo Nigro, L.; Lo Presti, D.; Loucatos, S.; Louis, F.; Lyashuk, V.; Magnier, P.; Marcelin, M.; Margiotta, A.; Maron, C.; Massol, A.; Mazéas, F.; Mazeau, B.; Mazure, A.; McMillan, J. E.; Michel, J.-L.; Millot, C.; Milovanovic, A.; Montanet, F.; Montaruli, T.; Morel, J.-P.; Moscoso, L.; Nezri, E.; Niess, V.; Nooren, G. J.; Ogden, P.; Olivetto, C.; Palanque-Delabrouille, N.; Payre, P.; Petta, C.; Pineau, J.-P.; Poinsignon, J.; Popa, V.; Potheau, R.; Pradier, T.; Racca, C.; Randazzo, N.; Real, D.; van Rens, B. A. P.; Réthoré, F.; Ripani, M.; Roca-Blay, V.; Romeyer, A.; Rollin, J.-F.; Romita, M.; Rose, H. J.; Rostovtsev, A.; Ruppi, M.; Russo, G. V.; Sacquin, Y.; Saouter, S.; Schuller, J.-P.; Schuster, W.; Sokalski, I.; Suvorova, O.; Spooner, N. J. C.; Spurio, M.; Stolarczyk, T.; Stubert, D.; Taiuti, M.; Thompson, L. F.; Tilav, S.; Usik, A.; Valdy, P.; Vallage, B.; Vaudaine, G.; Vernin, P.; Virieux, J.; Vladimirsky, E.; de Vries, G.; de Witt Huberts, P.; de Wolf, E.; Zaborov, D.; Zaccone, H.; Zakharov, V.; Zavatarelli, S.; de Zornoza, J. D.; Zúñiga, J.

    2005-02-01

    The ANTARES neutrino telescope is a large photomultiplier array designed to detect neutrino-induced upward-going muons by their Cherenkov radiation. Understanding the absorption and scattering of light in the deep Mediterranean is fundamental to optimising the design and performance of the detector. This paper presents measurements of blue and UV light transmission at the ANTARES site taken between 1997 and 2000. The derived values for the scattering length and the angular distribution of particulate scattering were found to be highly correlated, and results are therefore presented in terms of an absorption length λabs and an effective scattering length λscteff. The values for blue (UV) light are found to be λabs ≃ 60(26) m, λscteff≃265(122)m, with significant (˜15%) time variability. Finally, the results of ANTARES simulations showing the effect of these water properties on the anticipated performance of the detector are presented.

  8. Semi-automated high-efficiency reflectivity chamber for vacuum UV measurements

    NASA Astrophysics Data System (ADS)

    Wiley, James; Fleming, Brian; Renninger, Nicholas; Egan, Arika

    2017-08-01

    This paper presents the design and theory of operation for a semi-automated reflectivity chamber for ultraviolet optimized optics. A graphical user interface designed in LabVIEW controls the stages, interfaces with the detector system, takes semi-autonomous measurements, and monitors the system in case of error. Samples and an optical photodiode sit on an optics plate mounted to a rotation stage in the middle of the vacuum chamber. The optics plate rotates the samples and diode between an incident and reflected position to measure the absolute reflectivity of the samples at wavelengths limited by the monochromator operational bandpass of 70 nm to 550 nm. A collimating parabolic mirror on a fine steering tip-tilt motor enables beam steering for detector peak-ups. This chamber is designed to take measurements rapidly and with minimal oversight, increasing lab efficiency for high cadence and high accuracy vacuum UV reflectivity measurements.

  9. Irradiation of 4H-SiC UV detectors with heavy ions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalinina, E. V., E-mail: evk@mail.ioffe.ru; Lebedev, A. A.; Bogdanova, E.

    Ultraviolet (UV) photodetectors based on Schottky barriers to 4H-SiC are formed on lightly doped n-type epitaxial layers grown by the chemical vapor deposition method on commercial substrates. The diode structures are irradiated at 25°C by 167-MeV Xe ions with a mass of 131 amu at a fluence of 6 × 10{sup 9} cm{sup −2}. Comparative studies of the optical and electrical properties of as-grown and irradiated structures with Schottky barriers are carried out in the temperature range 23–180°C. The specific features of changes in the photosensitivity and electrical characteristics of the detector structures are accounted for by the capture ofmore » photogenerated carriers into traps formed due to fluctuations of the conduction-band bottom and valence-band top, with subsequent thermal dissociation.« less

  10. Results of TLE and TGF Observation in RELEC Experiment onboard "Vernov" Mission

    NASA Astrophysics Data System (ADS)

    Klimov, Pavel; Garipov, Gali; Klimov, Stanislav; Rothkaehl, Hanna; Khrenov, Boris; Pozanenko, Alexei; Morozenko, Violetta; Iyudin, Anatoly; Bogomolov, Vitalij V.; Svertilov, Sergey; Panasyuk, Mikhail; Saleev, Kirill; Kaznacheeva, Margarita; Maximov, Ivan

    2016-07-01

    "Vernov" satellite with RELEC experiment onboard was launched on 2014 July, 8 into a polar solar-synchronous orbit. The payload includes DUV ultraviolet and red photometer and DRGE gamma-ray spectrometer providing measurements in 10-3000 keV energy range with four detectors. Both instruments directed to the atmosphere. Total area of DRGE detectors is ˜500 cm ^{2}. The data were recorded both in monitoring and gamma by gamma modes with timing accuracy ˜15 μs. Several TGF candidates with 10-40 gammas in a burst with duration <1 ms were detected. Analysis of data from other instruments on-board "Vernov" satellite shows the absence of significant electromagnetic pulses around correspondent time moments. Comparison with a world wide lightning location network (WWLLN) data base also indicates that there were no thunderstorms connected with most of detected TGF candidates. Possible connection of TGF candidates with electron precipitations is discussed. Observations of transient luminous events (TLEs) were made in UV (240-400 nm) and IR (>610 nm) wavelength bands. More than 8 thousands of flashes with duration between 1 and 128 ms were detected from the atmosphere. Time profiles of detected flashes are very diverse. There are single peak events with significant UV and IR signal, multi-peak structures visible in the both UV and IR channels and very complicated events mixed from UV and IR signals and UV flashes which can continue even during the whole waveform. In addition, there are flashes of various temporal duration and structure measured only in UV wavelength range. Number of UV photons released in the atmosphere varies in a wide range from 10 ^{20} to 10 ^{26}. Apart from the events detected in the thunderstorm regions over the continents, many flashes were observed outside of thunderstorm areas, above the ocean and even at rather high latitudes. Such events are not associated with the thunderstorm and lightning activity measured by WWLLN. Various types of UV and IR flashes measurements and their interpretation, geographical, energy and spectral distribution are presented and discussed.

  11. The STIS MAMA status: Current detector performance

    NASA Technical Reports Server (NTRS)

    Danks, A. C.; Joseph, C.; Bybee, R.; Argebright, V.; Abraham, J.; Kimble, R.; Woodgate, B.

    1992-01-01

    The STIS (Space Telescope Imaging Spectrograph) is a second generation Hubble instrument scheduled to fly in 1997. Through a variety of modes, the instrument will provide spectral resolutions from R approximately 50 in the objective spectroscopy mode to 100,000 in the high resolution echelle mode in the wavelength region from 115 to 1000 nm. In the UV the instrument employs two MAMA (Multimode Anode Microchannel plate Arrays) 1024 by 1024 pixel detectors, which provide high DQE (Detective Quantum Efficiency), and good dynamic range and resolution. The current progress and performance of these detectors are reported, illustrating that the technology is mature and that the performance is very close to flight requirements.

  12. Spectral measurements of alpha-induced radioluminescence in various gases

    NASA Astrophysics Data System (ADS)

    Brett, Jaclyn; Koehler, Katrina E.; Bischak, Michael; Famiano, Michael; Jenkins, Jared; Klankowski, Levi; Niraula, Prashantamani; Pancella, Paul; Lakis, Rollin

    2017-12-01

    Radioluminescent emission in Ar, N2, O2, and dry air at P = 1 atm was observed induced by 5 MeV α particles. The wavelength range with a single detector spanned 250-1100 nm, extending the range well into the UV and IR bands with a single detector. Measured spectral lines for alpha-induced luminescence were corrected for detector transmission and intensities compared to previous work. The exploration of multiple gases over a wide frequency range opens the door to security and remote sensing applications, where different environments are routinely encountered. This work provides spectra that can be used in guiding future filter development focusing on remote alpha detection.

  13. Microchannel plate EUV detectors for the Extreme Ultraviolet Explorer

    NASA Technical Reports Server (NTRS)

    Siegmund, O. H. W.; Malina, R. F.; Coburn, K.; Werthimer, D.

    1984-01-01

    The design and operating characteristics of the prototype imaging microchannel plate (MCP) detector for the Extreme Ultraviolet Explorer (EUVE) Satellite are discussed. It is shown that this detector has achieved high position resolution performance (greater than 512 x 512 pixels) and has low (less than one percent) image distortion. In addition, the channel plate scheme used has tight pulse height distributions (less than 40 percent FWHM) for UV radiation and displays low (less than 0.2 cnt/sq cm-s) dark background counting rates. Work that has been done on EUV filters in relation to the envisaged filter and photocathode complement is also described.

  14. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of selected carbamate pesticides in water by high-performance liquid chromatography

    USGS Publications Warehouse

    Werner, S.L.; Johnson, S.M.

    1994-01-01

    As part of its primary responsibility concerning water as a national resource, the U.S. Geological Survey collects and analyzes samples of ground water and surface water to determine water quality. This report describes the method used since June 1987 to determine selected total-recoverable carbamate pesticides present in water samples. High- performance liquid chromatography is used to separate N-methyl carbamates, N-methyl carbamoyloximes, and an N-phenyl carbamate which have been extracted from water and concentrated in dichloromethane. Analytes, surrogate compounds, and reference compounds are eluted from the analytical column within 25 minutes. Two modes of analyte detection are used: (1) a photodiode-array detector measures and records ultraviolet-absorbance profiles, and (2) a fluorescence detector measures and records fluorescence from an analyte derivative produced when analyte hydrolysis is combined with chemical derivatization. Analytes are identified and confirmed in a three-stage process by use of chromatographic retention time, ultraviolet (UV) spectral comparison, and derivatization/fluorescence detection. Quantitative results are based on the integration of single-wavelength UV-absorbance chromatograms and on comparison with calibration curves derived from external analyte standards that are run with samples as part of an instrumental analytical sequence. Estimated method detection limits vary for each analyte, depending on the sample matrix conditions, and range from 0.5 microgram per liter to as low as 0.01 microgram per liter. Reporting levels for all analytes have been set at 0.5 microgram per liter for this method. Corrections on the basis of percentage recoveries of analytes spiked into distilled water are not applied to values calculated for analyte concentration in samples. These values for analyte concentrations instead indicate the quantities recovered by the method from a particular sample matrix.

  15. The Future of Single- to Multi-band Detector Technologies: Review

    NASA Technical Reports Server (NTRS)

    Abedin, M. Nurul; Bhat, Ishwara; Gunapala, Sarath D.; Bandara, Sumith V.; Refaat, Tamer F.; Sandford, Stephen P.; Singh, Upendra N.

    2006-01-01

    Using classical optical components such as filters, prisms and gratings to separate the desired wavelengths before they reach the detectors results in complex optical systems composed of heavy components. A simpler system will result by utilizing a single optical system and a detector that responds separately to each wavelength band. Therefore, a continuous endeavors to develop the capability to reliably fabricate detector arrays that respond to multiple wavelength regions. In this article, we will review the state-of-the-art single and multicolor detector technologies over a wide spectral-range, for use in space-based and airborne remote sensing applications. Discussions will be focused on current and the most recently developed focal plane arrays (FPA) in addition to emphasizing future development in UV-to-Far infrared multicolor FPA detectors for next generation space-based instruments to measure water vapor and greenhouse gases. This novel detector component will make instruments designed for these critical measurements more efficient while reducing complexity and associated electronics and weight. Finally, we will discuss the ongoing multicolor detector technology efforts at NASA Langley Research Center, Jet Propulsion Laboratory, Rensselaer Polytechnic Institute, and others.

  16. Effect of ambient temperature and internal relative humidity on spectral sensitivity of broadband UV detectors

    NASA Astrophysics Data System (ADS)

    Huber, Martin; Blumthaler, Mario; Schreder, Josef

    2002-01-01

    Within the frame of the Austrian UV Monitoring Network, repeated recalibrations of Solar Light Sunburn Meters between December 1997 and March 2000 have shown significant temporal changes in the instruments' relative spectral response function as well as in their absolute calibration. Therefore, laboratory investigations of the effects of ambient temperature and internal relative humidity on the behavior of two Sunburn Meters have been performed. Despite internal temperature stabilization, both instruments show significant dependence of their spectral response function on ambient temperature. When the outside temperature of the detector's housing varies between 13 degree(s)C and 44 degree(s)C, spectral sensitivity changes by up to 10% in the UVB range and by up to a factor of 2 in the UVA range, depending on internal relative humidity. As a consequence, output voltage variations of 10% are observed when the detector is mounted in front of a 1000 W halogen lamp and its internal relative humidity is changed while its ambient temperature is kept constant. Whereas temperature effects take place within several hours, instabilities due to variations in internal relative humidity show typical time constants in the order of several days.

  17. Objective for monitoring the corona discharge

    NASA Astrophysics Data System (ADS)

    Obrezkov, Andrey; Rodionov, Andrey Yu.; Pisarev, Viktor N.; Chivanov, Alexsey N.; Baranov, Yuri P.; Korotaev, Valery V.

    2016-04-01

    Remote optoelectronic probing is one of the most actual aspects of overhead electric line maintenances. By installing such systems on a helicopter (for example) it becomes possible to monitor overhead transmission line status and to search damaged parts of the lines. Thermal and UV-cameras are used for more effective diagnostic. UV-systems are fitted with filters, that attenuate visible spectrum, which is an undesired type of signal. Also these systems have a wide view angle for better view and proper diagnostics. For even more effectiveness, it is better to use several spectral channels: like UV and IR. Such spectral selection provides good noise reduction. Experimental results of spectral parameters of the wide view angle multispectral objective for such systems are provided in this report. There is also data on point spread function, UV and IR scattering index data and technical requirements for detectors.

  18. Optical Probe of the Superconducting Normal Mixed State in a Magnetic Penetration Thermometer

    NASA Technical Reports Server (NTRS)

    Stevenson, T. R.; Balvin, M. A.; Bandler, S. R.; Denis, K. L.; Lee, S. -J.; Nagler, P. C.; Smith, S. J.

    2016-01-01

    Using ultraviolet photon pulses, we have probed the internal behavior of a molybdenum-gold Magnetic Penetration Thermometer (MPT) that we designed for x-ray microcalorimetry. In this low-temperature detector, the diamagnetic response of a superconducting MoAu bilayer is used to sense temperature changes in response to absorbed photons. We have previously described an approximate model that explains the high responsivity of the detector to temperature changes as a consequence of a Meissner transition of the molybdenum-gold film in the magnetic field applied by the superconducting circuit used to bias the detector. We compare measurements of MPT heat capacity and thermal conductance, derived from UV photon pulse data, to our model predictions for the thermodynamic properties of the sensor and for the electron cooling obtained by quasiparticle recombination. Our data on electron cooling power is also relevant to the operation of other superconducting detectors, such as Microwave Kinetic Inductance Detectors.

  19. Fuzzy clustering evaluation of the discrimination power of UV-Vis and (±) ESI-MS detection system in individual or coupled RPLC for characterization of Ginkgo Biloba standardized extracts.

    PubMed

    Medvedovici, Andrei; Albu, Florin; Naşcu-Briciu, Rodica Domnica; Sârbu, Costel

    2014-02-01

    Discrimination power evaluation of UV-Vis and (±) electrospray ionization/mass spectrometric techniques, (ESI-MS) individually considered or coupled as detectors to reversed phase liquid chromatography (RPLC) in the characterization of Ginkgo Biloba standardized extracts, is used in herbal medicines and/or dietary supplements with the help of Fuzzy hierarchical clustering (FHC). Seventeen batches of Ginkgo Biloba commercially available standardized extracts from seven manufacturers were measured during experiments. All extracts were within the criteria of the official monograph dedicated to dried refined and quantified Ginkgo extracts, in the European Pharmacopoeia. UV-Vis and (±) ESI-MS spectra of the bulk standardized extracts in methanol were acquired. Additionally, an RPLC separation based on a simple gradient elution profile was applied to the standardized extracts. Detection was made through monitoring UV absorption at 220 nm wavelength or the total ion current (TIC) produced through (±) ESI-MS analysis. FHC was applied to raw, centered and scaled data sets, for evaluating the discrimination power of the method with respect to the origins of the extracts and to the batch to batch variability. The discrimination power increases with the increase of the intrinsic selectivity of the spectral technique being used: UV-Vis

  20. CdS-Nanowires Flexible Photo-detector with Ag-Nanowires Electrode Based on Non-transfer Process

    PubMed Central

    Pei, Yanli; Pei, Ruihan; Liang, Xiaoci; Wang, Yuhao; Liu, Ling; Chen, Haibiao; Liang, Jun

    2016-01-01

    In this study, UV-visible flexible resistivity-type photo-detectors were demonstrated with CdS-nanowires (NWs) percolation network channel and Ag-NWs percolation network electrode. The devices were fabricated on Mixed Cellulose Esters (MCE) membrane using a lithographic filtration method combined with a facile non-transfer process. The photo-detectors demonstrated strong adhesion, fast response time, fast decay time, and high photo sensitivity. The high performance could be attributed to the high quality single crystalline CdS-NWs, encapsulation of NWs in MCE matrix and excellent interconnection of the NWs. Furthermore, the sensing performance was maintained even the device was bent at an angle of 90°. This research may pave the way for the facile fabrication of flexible photo-detectors with high performances. PMID:26899726

  1. Molar absorptivities of 2,4-D, cymoxanil, fenpropidin, isoproturon and pyrimethanil in aqueous solution in the near-UV.

    PubMed

    Feigenbrugel, Valérie; Le Calvé, Stéphane; Mirabel, Philippe

    2006-01-01

    The absorption spectra of five pesticides, namely 2,4-dichloro-phenoxy acetic acid (2,4-D), cymoxanil, fenpropidin, isoproturon and pyrimethanil, have been measured in aqueous solution using a set-up consisting of two parallel absorption cells coupled to a CCD detector. The absolute values of their molar absorptivity coefficients epsilon were determined in the wavelength-range 240-344 nm with a deuterium-lamp at room temperature (298+/-2 K). Using the Beer-Lambert law, values of epsilon were also determined at 253.7 nm with a Hg-Lamp: epsilon = 145+/-14 for 2,4-D, epsilon = 7940+/-920 for cymoxanil, epsilon = 196+/-14 for fenpropidin, epsilon = 7330+/-880 for isoproturon, epsilon = 13200+/-1400 for pyrimethanil (in units of M(-1) cm(-1)). The quoted errors correspond to 2 sigma obtained from the least square fit analysis and the estimated systematic error of 5% due to the uncertainties in aqueous concentrations. For all the studied compounds, the absorbances measured were lower than 2.3 and did not exhibit any deviation from the Beer-Lambert's law. Our experimental data are discussed and compared to UV spectra of similar molecules when such data were available in the literature. Based on their UV spectra and the calculated fractions of these pesticides in the aqueous phase, their direct photolysis under sunlight environment could occur, except may be for fenpropidin, either in water surfaces or in aqueous droplets contained in the atmospheric clouds.

  2. Molar absorptivities of 2,4-D, cymoxanil, fenpropidin, isoproturon and pyrimethanil in aqueous solution in the near-UV

    NASA Astrophysics Data System (ADS)

    Feigenbrugel, Valérie; Le Calvé, Stéphane; Mirabel, Philippe

    2006-01-01

    The absorption spectra of five pesticides, namely 2,4-dichloro-phenoxy acetic acid (2,4-D), cymoxanil, fenpropidin, isoproturon and pyrimethanil, have been measured in aqueous solution using a set-up consisting of two parallel absorption cells coupled to a CCD detector. The absolute values of their molar absorptivity coefficients ɛ were determined in the wavelength-range 240-344 nm with a deuterium-lamp at room temperature (298 ± 2 K). Using the Beer-Lambert law, values of ɛ were also determined at 253.7 nm with a Hg-Lamp: ɛ = 145 ± 14 for 2,4-D, ɛ = 7940 ± 920 for cymoxanil, ɛ = 196 ± 14 for fenpropidin, ɛ = 7330 ± 880 for isoproturon, ɛ = 13200 ± 1400 for pyrimethanil (in units of M-1 cm-1). The quoted errors correspond to 2σ obtained from the least square fit analysis and the estimated systematic error of 5% due to the uncertainties in aqueous concentrations. For all the studied compounds, the absorbances measured were lower than 2.3 and did not exhibit any deviation from the Beer-Lambert's law. Our experimental data are discussed and compared to UV spectra of similar molecules when such data were available in the literature. Based on their UV spectra and the calculated fractions of these pesticides in the aqueous phase, their direct photolysis under sunlight environment could occur, except may be for fenpropidin, either in water surfaces or in aqueous droplets contained in the atmospheric clouds.

  3. Study on oligomerization of glutamate decarboxylase from Lactobacillus brevis using asymmetrical flow field-flow fractionation (AF4) with light scattering techniques.

    PubMed

    Choi, Jaeyeong; Lee, Seungho; Linares-Pastén, Javier A; Nilsson, Lars

    2018-01-01

    In this work, asymmetrical flow field-flow fractionation (AF4) coupled with UV/Vis, multi-angle light scattering (MALS), and differential refractive index (dRI) detectors (AF4-UV-MALS-dRI) was employed for analysis of glutamate decarboxylase (LbGadB) from Lactobacillus brevis (L. brevis). AF4 provided molecular weight (MW) (or size)-based separation of dimer, hexamer, and aggregates of LbGadB. The effect of pH on oligomerization of LbGadB was investigated, and then AF4 results were compared to those from molecular modeling. The MWs measured by AF4-UV-MALS-dRI for dimeric and hexameric forms of LbGadB were 110 and 350 kDa, respectively, which are in good agreements with those theoretically calculated (110 and 330 kDa). The molecular sizes determined by AF4-UV-MALS-dRI were also in good agreement with those obtained from molecular modeling (6 and 10 nm, respectively, for dimeric and hexameric from AF4-UV-MALS-dRI and 6.4 × 7.6 and 7.6 × 13.1 nm from molecular modeling). The effects of temperature, salt type, and salt concentration on oligomerization of LbGadB were also investigated using dynamic light scattering (DLS). It was found that the hexameric form of LbGadB was most stable at pH 6 and in presence of NaCl or KCl. The results indicate that AF4, in combination of various online detectors mentioned above, provides an effective tool for monitoring of oligomerization of LbGadB under different conditions, such as temperature, pH, type of salts, and salt concentrations.

  4. FogEye UV Sensor System Performance Characteristics

    DOT National Transportation Integrated Search

    2004-03-01

    The primary objective of the FogEye Evaluation Program is to determine whether coupled ultra-violet sources and detectors may provide enhancements to safety on the airport surface. The results of this effort will be used to complete the evaluation of...

  5. Enhanced UV exposure on a ski-field compared with exposures at sea level.

    PubMed

    Allen, Martin; McKenzie, Richard

    2005-05-01

    Personal erythemal UV monitoring badges, which were developed to monitor the UV exposure of school children, were used to measure UV exposures received by one of the authors (MA) at the Mt Hutt ski-field, in New Zealand. These were then compared with measurements taken at the same times from a nearby sea level site in Christchurch city. The badges were designed to give instantaneous readings of erythemally-weighted (i.e., "sun burning") UV radiation and were cross-calibrated against meteorological grade UV instruments maintained by the National Institute of Water & Atmospheric Research (NIWA). All skiing and calibration days were clear and almost exclusively cloud free. It was found that the UV maxima for horizontal surfaces at the ski-field (altitude approximately 2 km) were 20-30% greater than at the low altitude site. Larger differences between the sites were observed when the sensor was oriented perpendicular to the sun. The personal doses of UV received by a sensor on the skier's lapel during two days of skiing activity were less than those received by a stationary detector on a horizontal surface near sea level. The exposures depended strongly on the time of year, and in mid-October the maximum UV intensity on the ski-field was 60% greater than in mid-September. The UV exposure levels experienced during skiing were smaller than the summer maxima at low altitudes.

  6. Communication using eye roll reflective signalling

    USGS Publications Warehouse

    Flamarique, I.N.; Mueller, G.A.; Cheng, C.L.; Figiel, C.R.

    2007-01-01

    Body reflections in the ultraviolet (UV) are a common occurrence in nature. Despite the abundance of such signals and the presence of UV cones in the retinas of many vertebrates, the function of UV cones in the majority of taxa remains unclear. Here, we report on an unusual communication system in the razorback sucker, Xyrauchen texanus, that involves flash signals produced by quick eye rolls. Behavioural experiments and field observations indicate that this form of communication is used to signal territorial presence between males. The flash signal shows highest contrast in the UV region of fhe visual spectrum (??max???380 nm), corresponding to the maximum wavelength of absorption of the UV cone mechanism in suckers. Furthermore, these cones are restricted to the dorsal retina of the animal and the upwelling light background is such that their relative sensitivity would be enhanced by chromatic adaptation of the other cone mechanisms. Thus, the UV cones in the sucker have optimal characteristics (both in terms of absorbance and retinal topography) to constitute the main detectors of the flash signal. Our findings provide the first ecological evidence for restricted distribution of UV cones in the retina of a vertebrate. ?? 2007 The Royal Society.

  7. Cross strip anode readouts for microchannel plate detectors: developing flight qualified prototypes

    NASA Astrophysics Data System (ADS)

    Vallerga, John; Cooney, M.; Raffanti, R.; Varner, G.; Siegmund, O.; McPhate, J. B.; Tremsin, A.

    2014-01-01

    Photon counting microchannel plate (MCP) imagers have been the detector of choice for most UV astronomical missions over the last two decades (eg. EUVE, FUSE, COS on Hubble etc.). Over this duration, improvements in the MCP laboratory readout technology have resulted in better spatial resolution (x10), temporal resolution (x 1000) and output event rate (x100), all the while operating at lower gain (x 10) resulting in lower high voltage requirements and longer MCP lifetimes. One such technology is the parallel cross strip (PXS) readout. The PXS anode is a set of orthogonal conducting strips (80 x 80), typically spaced at a 635 micron pitch onto which charge clouds from MCP amplified events land. Each strip has its own charge sensitive amplifier that is sampled continuously by a dedicated analog to digital (ADC) converter at 50MHz. All of the 160 ADC digital output lines are fed into a field programmable gate array (FGPA) which can detect charge events landing on the strips, measure the peak amplitudes of those charge events and calculate their spatial centroid along with their time of arrival (X,Y,T). Laboratory versions of these electronics have demonstrated < 20 microns FWHM spatial resolution, count rates on the order of 2 MHz, and temporal resolution of ~ 1ns. In 2012 the our group at U.C. Berkeley, along with our partners at the U. Hawaii, received a Strategic Astrophysics Technology grant to raise the TRL of the PXS detector from 4 to 6 by replacing most of the 19" rack mounted, high powered electronics with application specific integrated circuits (ASICs) which will lower the power, mass and volume requirements of the PXS detector. We were also tasked to design and fabricate a "standard" 50mm square active area MCP detector incorporating these electronics that can be environmentally qualified for flight (temperature, vacuum, vibration). This detector design could then be modified for individual flight opportunities with a higher level of confidence than starting from scratch. We will present the latest progress on the ASIC designs, fabrication and performance and show imaging results from the 50mm XS detector using our current laboratory PXS electronics.

  8. Evaluation of machine learning algorithms for classification of primary biological aerosol using a new UV-LIF spectrometer

    NASA Astrophysics Data System (ADS)

    Ruske, Simon; Topping, David O.; Foot, Virginia E.; Kaye, Paul H.; Stanley, Warren R.; Crawford, Ian; Morse, Andrew P.; Gallagher, Martin W.

    2017-03-01

    Characterisation of bioaerosols has important implications within environment and public health sectors. Recent developments in ultraviolet light-induced fluorescence (UV-LIF) detectors such as the Wideband Integrated Bioaerosol Spectrometer (WIBS) and the newly introduced Multiparameter Bioaerosol Spectrometer (MBS) have allowed for the real-time collection of fluorescence, size and morphology measurements for the purpose of discriminating between bacteria, fungal spores and pollen.This new generation of instruments has enabled ever larger data sets to be compiled with the aim of studying more complex environments. In real world data sets, particularly those from an urban environment, the population may be dominated by non-biological fluorescent interferents, bringing into question the accuracy of measurements of quantities such as concentrations. It is therefore imperative that we validate the performance of different algorithms which can be used for the task of classification.For unsupervised learning we tested hierarchical agglomerative clustering with various different linkages. For supervised learning, 11 methods were tested, including decision trees, ensemble methods (random forests, gradient boosting and AdaBoost), two implementations for support vector machines (libsvm and liblinear) and Gaussian methods (Gaussian naïve Bayesian, quadratic and linear discriminant analysis, the k-nearest neighbours algorithm and artificial neural networks).The methods were applied to two different data sets produced using the new MBS, which provides multichannel UV-LIF fluorescence signatures for single airborne biological particles. The first data set contained mixed PSLs and the second contained a variety of laboratory-generated aerosol.Clustering in general performs slightly worse than the supervised learning methods, correctly classifying, at best, only 67. 6 and 91. 1 % for the two data sets respectively. For supervised learning the gradient boosting algorithm was found to be the most effective, on average correctly classifying 82. 8 and 98. 27 % of the testing data, respectively, across the two data sets.A possible alternative to gradient boosting is neural networks. We do however note that this method requires much more user input than the other methods, and we suggest that further research should be conducted using this method, especially using parallelised hardware such as the GPU, which would allow for larger networks to be trained, which could possibly yield better results.We also saw that some methods, such as clustering, failed to utilise the additional shape information provided by the instrument, whilst for others, such as the decision trees, ensemble methods and neural networks, improved performance could be attained with the inclusion of such information.

  9. Super sensitive UV detector using polymer functionalized nanobelts

    DOEpatents

    Wang, Zhong L; Lao, Changshi; Zhou, Jun

    2012-10-23

    An ultraviolet light sensor includes an elongated metal oxide nanostructure, a layer of an ultraviolet light-absorbing polymer, a current source and a current detector. The elongated metal oxide nanostructure has a first end and an opposite second end. The layer of an ultraviolet light-absorbing polymer is disposed about at least a portion of the metal oxide nanostructure. The current source is configured to provide electrons to the first end of the metal oxide nanostructure. The current detector is configured to detect an amount of current flowing through the metal oxide nanostructure. The amount of current flowing through the metal oxide nanostructure corresponds to an amount of ultraviolet light impinging on the metal oxide nanostructure.

  10. Application of a liquid chromatography detector to time-resolved RYDMR spectroscopy: a comparison of in situ and ex post facto measurements

    NASA Astrophysics Data System (ADS)

    Sakaguchi, Yoshio

    2001-09-01

    A photodiode-array (PDA) UV-VIS detector for liquid chromatography is applied to time-resolved reaction yield detected magnetic resonance (RYDMR) measurements. The results derived from the yields of cage and escape products in the photoreaction of 2-methyl-1, 4-naphtnoquinone in a sodium dodecylsulfate micelle are found to be identical with those derived from the yield of escaping semiquinone radical detected by transient optical absorption. This implies practical linearity between the yields of escaping radicals and escape products. High sensitivity of the PDA detector enables application of escape product yields for kinetic analysis by reducing microwave-induced perturbation.

  11. Spectral Measurements of Alpha-induced Radioluminescence in Various Gases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brett, Jaclyn; Koehler, Katrina Elizabeth; Bischak, Michael

    Radioluminescent emission in Ar, N 2, O 2, and dry air at P=1 atm was observed induced by 5 MeV α particles. The wavelength range with a single detector spanned 250–1100 nm, extending the range well into the UV and IR bands with a single detector. Measured spectral lines for alpha-induced luminescence were corrected for detector transmission and intensities compared to previous work. The exploration of multiple gases over a wide frequency range opens the door to security and remote sensing applications, where different environments are routinely encountered. Finally, this work provides spectra that can be used in guiding futuremore » filter development focusing on remote alpha detection.« less

  12. Spectral Measurements of Alpha-induced Radioluminescence in Various Gases

    DOE PAGES

    Brett, Jaclyn; Koehler, Katrina Elizabeth; Bischak, Michael; ...

    2017-09-06

    Radioluminescent emission in Ar, N 2, O 2, and dry air at P=1 atm was observed induced by 5 MeV α particles. The wavelength range with a single detector spanned 250–1100 nm, extending the range well into the UV and IR bands with a single detector. Measured spectral lines for alpha-induced luminescence were corrected for detector transmission and intensities compared to previous work. The exploration of multiple gases over a wide frequency range opens the door to security and remote sensing applications, where different environments are routinely encountered. Finally, this work provides spectra that can be used in guiding futuremore » filter development focusing on remote alpha detection.« less

  13. New Linear Partitioning Models Based on Experimental Water: Supercritical CO2 Partitioning Data of Selected Organic Compounds.

    PubMed

    Burant, Aniela; Thompson, Christopher; Lowry, Gregory V; Karamalidis, Athanasios K

    2016-05-17

    Partitioning coefficients of organic compounds between water and supercritical CO2 (sc-CO2) are necessary to assess the risk of migration of these chemicals from subsurface CO2 storage sites. Despite the large number of potential organic contaminants, the current data set of published water-sc-CO2 partitioning coefficients is very limited. Here, the partitioning coefficients of thiophene, pyrrole, and anisole were measured in situ over a range of temperatures and pressures using a novel pressurized batch-reactor system with dual spectroscopic detectors: a near-infrared spectrometer for measuring the organic analyte in the CO2 phase and a UV detector for quantifying the analyte in the aqueous phase. Our measured partitioning coefficients followed expected trends based on volatility and aqueous solubility. The partitioning coefficients and literature data were then used to update a published poly parameter linear free-energy relationship and to develop five new linear free-energy relationships for predicting water-sc-CO2 partitioning coefficients. A total of four of the models targeted a single class of organic compounds. Unlike models that utilize Abraham solvation parameters, the new relationships use vapor pressure and aqueous solubility of the organic compound at 25 °C and CO2 density to predict partitioning coefficients over a range of temperature and pressure conditions. The compound class models provide better estimates of partitioning behavior for compounds in that class than does the model built for the entire data set.

  14. Absolute spectral response measurements of different photodiodes useful for applications in the UV spectral region

    NASA Astrophysics Data System (ADS)

    Pelizzo, Maria G.; Ceccherini, Paolo; Garoli, Denis; Masut, Pietro; Nicolosi, Piergiorgio

    2004-09-01

    Long UV radiation exposure can result in damages of biological tissues, as burns, skin aging, erythema and even melanoma cancer. In the past years an increase of melanoma cancer has been observed and associated to the atmospheric ozone deployment. Attendance of sun tanning unit centers has become a huge social phenomena, and the maximum UV radiation dose that a human being can receive is regulated by law. On the other side, UV radiation is largely used for therapeutic and germicidal purposes. In all these areas, spectroradiometer and radiomenter are needed for monitoring UVA (315-400 nm), UVB (280-315 nm) and UVC (100-280 nm) irradiance. We have selected some commercial photodiodes which can be used as solid state detectors in these instruments. We have characterized them by measuring their absolute spectral response in the 200 - 400 nm spectral range.

  15. FogEye UV Sensor System Evaluation : Phase II Report

    DOT National Transportation Integrated Search

    2003-12-01

    The primary objective of the FogEye Evaluation Program is to determine whether coupled ultra-violet sources and detectors may provide enhancements to safety on the airport surface. The results of this effort will be used to complete the evaluation of...

  16. Prototype readout system for a multi Mpixels UV single-photon imaging detector capable of space flight operation

    NASA Astrophysics Data System (ADS)

    Seljak, A.; Cumming, H. S.; Varner, G.; Vallerga, J.; Raffanti, R.; Virta, V.

    2018-02-01

    Our collaboration works on the development of a large aperture, high resolution, UV single-photon imaging detector, funded through NASA's Strategic Astrophysics Technology (SAT) program. The detector uses a microchannel plate for charge multiplication, and orthogonal cross strip (XS) anodes for charge readout. Our target is to make an advancement in the technology readiness level (TRL), which enables real scale prototypes to be tested for future NASA missions. The baseline detector has an aperture of 50×50 mm and requires 160 low-noise charge-sensitive channels, in order to extrapolate the incoming photon position with a spatial resolution of about 20 μm FWHM. Technologies involving space flight require highly integrated electronic systems operating at very low power. We have designed two ASICs which enable the construction of such readout system. First, a charge sensitive amplifier (CSAv3) ASIC provides an equivalent noise charge (ENC) of around 600 e-, and a baseline gain of 10 mV/fC. The second, a Giga Sample per Second (GSPS) ASIC, called HalfGRAPH, is a 12-bit analog to digital converter. Its architecture is based on waveform sampling capacitor arrays and has about 8 μs of analog storage memory per channel. Both chips encapsulate 16 measurement channels. Using these chips, a small scale prototype readout system has been constructed on a FPGA Mezzanine Board (FMC), equipped with 32 measurement channels for system evaluation. We describe the construction of HalfGRAPH ASIC, detector's readout system concept and obtained results from the prototype system. As part of the space flight qualification, these chips were irradiated with a Cobalt gamma-ray source, to verify functional operation under ionizing radiation exposure.

  17. Intermediate type excitons in Schottky barriers of A3B6 layer semiconductors and UV photodetectors

    NASA Astrophysics Data System (ADS)

    Alekperov, O. Z.; Guseinov, N. M.; Nadjafov, A. I.

    2006-09-01

    Photoelectric and photovoltaic spectra of Schottky barrier (SB) structures of InSe, GaSe and GaS layered semiconductors (LS) are investigated at quantum energies from the band edge excitons of corresponding materials up to 6.5eV. Spectral dependences of photoconductivity (PC) of photo resistors and barrier structures are strongly different at the quantum energies corresponding to the intermediate type excitons (ITE) observed in these semiconductors. It was suggested that high UV photoconductivity of A3B6 LS is due to existence of high mobility light carriers in the depth of the band structure. It is shown that SB of semitransparent Au-InSe is high sensitive photo detector in UV region of spectra.

  18. Broadband Radiometric LED Measurements

    PubMed Central

    Eppeldauer, G. P.; Cooksey, C. C.; Yoon, H. W.; Hanssen, L. M.; Podobedov, V. B.; Vest, R. E.; Arp, U.; Miller, C. C.

    2017-01-01

    At present, broadband radiometric measurements of LEDs with uniform and low-uncertainty results are not available. Currently, either complicated and expensive spectral radiometric measurements or broadband photometric LED measurements are used. The broadband photometric measurements are based on the CIE standardized V(λ) function, which cannot be used in the UV range and leads to large errors when blue or red LEDs are measured in its wings, where the realization is always poor. Reference irradiance meters with spectrally constant response and high-intensity LED irradiance sources were developed here to implement the previously suggested broadband radiometric LED measurement procedure [1, 2]. Using a detector with spectrally constant response, the broadband radiometric quantities of any LEDs or LED groups can be simply measured with low uncertainty without using any source standard. The spectral flatness of filtered-Si detectors and low-noise pyroelectric radiometers are compared. Examples are given for integrated irradiance measurement of UV and blue LED sources using the here introduced reference (standard) pyroelectric irradiance meters. For validation, the broadband measured integrated irradiance of several LED-365 sources were compared with the spectrally determined integrated irradiance derived from an FEL spectral irradiance lamp-standard. Integrated responsivity transfer from the reference irradiance meter to transfer standard and field UV irradiance meters is discussed. PMID:28649167

  19. Broadband Radiometric LED Measurements.

    PubMed

    Eppeldauer, G P; Cooksey, C C; Yoon, H W; Hanssen, L M; Podobedov, V B; Vest, R E; Arp, U; Miller, C C

    2016-01-01

    At present, broadband radiometric measurements of LEDs with uniform and low-uncertainty results are not available. Currently, either complicated and expensive spectral radiometric measurements or broadband photometric LED measurements are used. The broadband photometric measurements are based on the CIE standardized V(λ) function, which cannot be used in the UV range and leads to large errors when blue or red LEDs are measured in its wings, where the realization is always poor. Reference irradiance meters with spectrally constant response and high-intensity LED irradiance sources were developed here to implement the previously suggested broadband radiometric LED measurement procedure [1, 2]. Using a detector with spectrally constant response, the broadband radiometric quantities of any LEDs or LED groups can be simply measured with low uncertainty without using any source standard. The spectral flatness of filtered-Si detectors and low-noise pyroelectric radiometers are compared. Examples are given for integrated irradiance measurement of UV and blue LED sources using the here introduced reference (standard) pyroelectric irradiance meters. For validation, the broadband measured integrated irradiance of several LED-365 sources were compared with the spectrally determined integrated irradiance derived from an FEL spectral irradiance lamp-standard. Integrated responsivity transfer from the reference irradiance meter to transfer standard and field UV irradiance meters is discussed.

  20. First report in a river in France of the benthic cyanobacterium Phormidium favosum producing anatoxin-a associated with dog neurotoxicosis.

    PubMed

    Gugger, Muriel; Lenoir, Séverine; Berger, Céline; Ledreux, Aurélie; Druart, Jean-Claude; Humbert, Jean-François; Guette, Catherine; Bernard, Cécile

    2005-06-01

    The first identification of anatoxin-a in a French lotic system is reported. Rapid deaths of dogs occurred in 2003 after the animals drank water from the shoreline of the La Loue River in eastern France. Sediments, stones and macrophytes surfaces at the margin of the river were covered by a thick biofilm containing large quantities of several benthic species of filamentous, non-heterocystous cyanobacteria. Known cyanotoxins, such as microcystins, saxitoxins and anatoxins were screened from biofilm samples by biochemical and analytical assays. A compound with similar UV spectra to the anatoxin-a standard was detected by high-performance liquid chromatography (HPLC) coupled with photo-diode array detector. This toxin was further identified by HPLC coupled with a UV detector and by electrospray ionisation-Quadrupole-Time-Of-Flight mass spectrometer, and confirmed by tandem mass spectrometry. These two techniques were necessary to discriminate anatoxin-a in phenylalanine-containing matrices such as liver samples of poisoned dogs. The toxin and the aromatic amino acid, phenylalanine, present the same pseudomolecular ion at m/z 166, but have differing fragmentation patterns, retention times and UV spectra. Finally, several cyanobacterial strains were isolated from the green biofilm and tested for anatoxin-a production. Phormidium favosum was identified as a new anatoxin-a producing species.

  1. UV detector based on InAlN/GaN-on-Si HEMT stack with photo-to-dark current ratio > 107

    NASA Astrophysics Data System (ADS)

    kumar, Sandeep; Pratiyush, Anamika Singh; Dolmanan, Surani B.; Tripathy, Sudhiranjan; Muralidharan, Rangarajan; Nath, Digbijoy N.

    2017-12-01

    We demonstrate an InAlN/GaN-on-Si high electron mobility transistor based UV detector with a photo-to-dark current ratio of >107. The Ti/Al/Ni/Au metal stack was evaporated and thermal annealed rapidly for Ohmic contacts to the 2D electron gas (2DEG) at the InAlN/GaN interface, while the channel + barrier was recess etched to a depth of 20 nm to pinch-off the 2DEG between Source-Drain pads. A spectral responsivity (SR) of 32.9 A/W at 367 nm was measured at 5 V. A very high photo-to-dark current ratio of >107 was measured at a bias of 20 V. The photo-to-dark current ratio at a fixed bias was found to be decreasing with an increase in the recess length of photodetectors. The fabricated devices were found to exhibit a UV-to-visible rejection ratio of >103 with a low dark current of < 32 pA at 5 V. Transient measurements showed rise and fall times in the range of 3-4 ms. The gain mechanism was investigated, and carrier lifetimes were estimated which matched well with those reported elsewhere.

  2. Response of biological uv dosimeters to the simulated extraterrestrial uv radiation

    NASA Astrophysics Data System (ADS)

    Bérces, A.; Rontó, G.; Kerékgyártó, T.; Kovács, G.; Lammer, H.

    In the Laboratory polycrystalline uracil thin layer and bacteriophage T7 detectors have been developed for UV dosimetry on the EarthSs surface. Exponential response of the uracil polycrystal has been detected both by absorption spectroscopy and measurements of the refractive index under the influence of terrestrial solar radiation or using UV-C sources. In UV biological dosimetry the UV dose scale is additive starting at a value of zero according to the definition of CIE (Technical Report TC-6-18). The biological dose can be defined by a measured end-effect. In our dosimeters (phage T7 and uracil dosimeter) exposed to natural (terrestrial) UV radiation the proportion of pyrimidin photoproducts among the total photoproducts is smaller than 0.1 and the linear correlation between the biological and physical dose is higher than 0.9. According to the experimental data this linear relationship is often not valid. We observed that UV radiation did not only induce dimerisation but shorter wavelengths caused monomerisation of pyrimidin dimers. Performing the irradiation in oxygen free environment and using a Deuterium lamp as UV source, we could increase monomerisation against dimerisation thus the DNA-based dosimetrySs additivity rule is not fulfilled in these conditions. In this study we will demonstrate those non-linear experiments which constitute the basis of our biological experiments on the International Space Station.

  3. Review—hexagonal boron nitride epilayers: Growth, optical properties and device applications

    DOE PAGES

    Jiang, H. X.; Lin, Jing Yu

    2016-09-07

    This paper provides a brief overview on recent advances made in authors’ laboratory in epitaxial growth and optical studies of hexagonal boron nitride (h-BN) epilayers and heterostructures. Photoluminescence spectroscopy has been employed to probe the optical properties of h-BN. It was observed that the near band edge emission of h-BN is unusually high and is more than two orders of magnitude higher than that of high quality AlN epilayers. It was shown that the unique quasi-2D nature induced by the layered structure of h-BN results in high optical absorption and emission. The impurity related and near band-edge transitions in h-BNmore » epilayers were probed for materials synthesized under varying ammonia flow rates. Our results have identified that the most dominant impurities and deep level defects in h-BN epilayers are related to nitrogen vacancies. By growing h-BN under high ammonia flow rates, nitrogen vacancy related defects can be eliminated and epilayers exhibiting pure free exciton emission have been obtained. Deep UV and thermal neutron detectors based on h-BN epilayers were shown to possess unique features. Lastly, it is our belief that h-BN will lead to many potential applications from deep UV emitters and detectors, radiation detectors, to novel 2D photonic and electronic devices.« less

  4. Review—hexagonal boron nitride epilayers: Growth, optical properties and device applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiang, H. X.; Lin, Jing Yu

    This paper provides a brief overview on recent advances made in authors’ laboratory in epitaxial growth and optical studies of hexagonal boron nitride (h-BN) epilayers and heterostructures. Photoluminescence spectroscopy has been employed to probe the optical properties of h-BN. It was observed that the near band edge emission of h-BN is unusually high and is more than two orders of magnitude higher than that of high quality AlN epilayers. It was shown that the unique quasi-2D nature induced by the layered structure of h-BN results in high optical absorption and emission. The impurity related and near band-edge transitions in h-BNmore » epilayers were probed for materials synthesized under varying ammonia flow rates. Our results have identified that the most dominant impurities and deep level defects in h-BN epilayers are related to nitrogen vacancies. By growing h-BN under high ammonia flow rates, nitrogen vacancy related defects can be eliminated and epilayers exhibiting pure free exciton emission have been obtained. Deep UV and thermal neutron detectors based on h-BN epilayers were shown to possess unique features. Lastly, it is our belief that h-BN will lead to many potential applications from deep UV emitters and detectors, radiation detectors, to novel 2D photonic and electronic devices.« less

  5. Fiber optic systems in the UV region

    NASA Astrophysics Data System (ADS)

    Huebner, Michael; Meyer, H.; Klein, Karl-Friedrich; Hillrichs, G.; Ruetting, Martin; Veidemanis, M.; Spangenberg, Bernd; Clarkin, James P.; Nelson, Gary W.

    2000-05-01

    Mainly due to the unexpected progress in manufacturing of solarization-reduced all-silica fibers, new fiber-optic applications in the UV-region are feasible. However, the other components like the UV-sources and the detector- systems have to be improved, too. Especially, the miniaturization is very important fitting to the small-sized fiber-optic assemblies leading to compact and mobile UV- analytical systems. Based on independent improvements in the preform and fiber processing, UV-improved fibers with different properties have been developed. The best UV-fiber for the prosed applications is selectable by its short and long-term spectral behavior, especially in the region from 190 to 350 nm. The spectrum of the UV-source and the power density in the fiber have an influence on the nonlinear transmission and the damaging level; however, hydrogen can reduce the UV-defect concentration. After determining the diffusion processes in the fiber, the UV-lifetime in commercially available all-silica fibers can be predicted. Newest results with light from deuterium-lamps, excimer- lasers and 5th harmonics of Nd:YAG laser will be shown. Many activities are in the field of UV-sources. In addition to new UV-lasers like the Nd:YAG laser at 213 nm, a new low- power deuterium-lamp with smaller dimensions has been introduced last year. Properties of this lamp will be discussed, taking into account some of the application requirements. Finally, some new applications with UV-fiber optics will be shown; especially the TLC-method can be improved significantly, combining a 2-row fiber-array with a diode-array spectrometer optimized for fiber-optics.

  6. MAMA detector systems - A status report

    NASA Technical Reports Server (NTRS)

    Timothy, J. Gethyn; Morgan, Jeffrey S.; Slater, David C.; Kasle, David B.; Bybee, Richard L.

    1989-01-01

    Third-generation, 224 x 960 and 360 x 1024-pixel multianode microchannel (MAMA) detectors are under development for satellite-borne FUV and EUV observations, using pixel dimensions of 25 x 25 microns. An account is presently given of the configurations, modes of operation, and recent performance data of these systems. At UV and visible wavelengths, these MAMAs employ a semitransparent, proximity-focused photocathode structure. At FUV and EUV wavelengths below about 1500 A, opaque alkali-halide photocathodes deposited directly on the front surface of the MCP furnish the best detective quantum efficiencies.

  7. Research on APD-based non-line-of-sight UV communication system

    NASA Astrophysics Data System (ADS)

    Wang, Rongyang; Wang, Ling; Li, Chao; Zhang, Wenjing; Yuan, Yonggang; Xu, Jintong; Zhang, Yan; Li, Xiangyang

    2010-10-01

    In this paper, specific issues in designing an avalanche photodiode (APD)-based non-line-of-sight (NLOS) ultraviolet (UV) communication system are investigated. A proper wavelength of the UV LEDs and a system configuration should be considered carefully to assure the feasibility of this system. Using the single scattering model, the received optical power at the sensitive area of the APD can be calculated. According to the calculation, it revealed that the scattered ultraviolet signal level was very low; therefore, a post signal processing circuit was necessary. The authors put forward the key components of the circuit based on the compromise between signal bandwidth and gain. The performance of this circuit was evaluated by means of software simulation, and continued work was involved to improve its signal noise ratio (SNR). The transmitter used in this system was 365 nm UV LED array. Strictly speaking, this was not the practical outdoor UV communication system. Since the scattering coefficient of 365 nm UV only drops a little compared with solar blind UV, the research-grade UV communication could be carried out in a darkroom without a great influence. By combining an APD with a compound parabolic concentrator (CPC) optical system, the effective collection area and field of view (FOV) of the detector could be adjusted. Several issues were also raised to improve the performance of UV communication system, including using more powerful UV LEDs and choosing suitable modulation schemes.

  8. Achieving Higher Strength and Sensitivity toward UV Light in Multifunctional Composites by Controlling the Thickness of Nano-Layer on the Surface of Glass Fiber.

    PubMed

    Sun, Chao; Zhang, Jie; Gao, Shanglin; Zhang, Nan; Zhang, Yijun; Zhuang, Jian; Liu, Ming; Zhang, Xiaohui; Ren, Wei; Wu, Hua; Ye, Zuo-Guang

    2018-06-18

    The interphase between fiber and matrix plays an essential role in the performance of composites. Therefore, the ability to design or modify the interphase is a key technology needed to manufacture stronger and smarter composite. Recently, depositing nano-materials onto the surface of the fiber has become a promising approach to optimize the interphase and composites. But, the modified composites have not reached the highest strength yet, because the determining parameters, such as thickness of the nano-layer, are hardly controlled by the mentioned methods in reported works. Here, we deposit conformal ZnO nano-layer with various thicknesses onto the surfaces of glass fibers via the atomic layer deposition (ALD) method and a tremendous enhancement of interfacial shear strength of composites is achieved. Importantly, a critical thickness of ZnO nano-layer is obtained for the first time, giving rise to a maximal relative enhancement in the interfacial strength, which is more than 200% of the control fiber. In addition, the single modified fiber exhibits a potential application as a flexible, transparent, in-situ UV detector in composites. And, we find the UV-sensitivity also shows a strong correlation with the thickness of ZnO. To reveal the dependence of UV-sensitivity on thickness, a depletion thickness is estimated by a proposed model which is an essential guide to design the detectors with higher sensitivity. Consequently, such precise tailoring of the interphase offers an advanced way to improve and to flexibly control various macroscopic properties of multifunctional composites of the next generation.

  9. An ultraviolet imager to study bright UV sources

    NASA Astrophysics Data System (ADS)

    Mathew, Joice; Prakash, Ajin; Sarpotdar, Mayuresh; Sreejith, A. G.; Safonova, Margarita; Murthy, Jayant

    2016-07-01

    We have designed and developed a compact ultraviolet imaging payload to y on a range of possible platforms such as high altitude balloon experiments, cubesats, space missions, etc. The primary science goals are to study the bright UV sources (mag < 10) and also to look for transients in the Near UV (200 - 300 nm) domain. Our first choice is to place this instrument on a spacecraft going to the Moon as part of the Indian entry into Google lunar X-Prize competition. The major constraints for the instrument are, it should be lightweight (< 2Kg), compact (length < 50cm) and cost effective. The instrument is an 80 mm diameter Cassegrain telescope with a field of view of around half a degree designated for UV imaging. In this paper we will discuss about the various science cases that can be performed by having observations with the instrument on different platforms. We will also describe the design, development and the current state of implementation of the instrument. This includes opto-mechanical and electrical design of the instrument. We have adopted an all spherical optical design which would make the system less complex to realize and a cost effective solution compared to other telescope configuration. The structural design has been chosen in such a way that it will ensure that the instrument could withstand all the launch load vibrations. An FPGA based electronics board is used for the data acquisition, processing and CCD control. We will also brie y discuss about the hardware implementation of the detector interface and algorithms for the detector readout and data processing.

  10. Dual-wavelength light-emitting diode-based ultraviolet absorption detector for nano-flow capillary liquid chromatography.

    PubMed

    Xie, Xiaofeng; Tolley, Luke T; Truong, Thy X; Tolley, H Dennis; Farnsworth, Paul B; Lee, Milton L

    2017-11-10

    The design of a miniaturized LED-based UV-absorption detector was significantly improved for on-column nanoflow LC. The detector measures approximately 27mm×24mm×10mm and weighs only 30g. Detection limits down to the nanomolar range and linearity across 3 orders of magnitude were obtained using sodium anthraquinone-2-sulfonate as a test analyte. Using two miniaturized detectors, a dual-detector system was assembled containing 255nm and 275nm LEDs with only 216nL volume between the detectors A 100μm slit was used for on-column detection with a 150μm i.d. packed capillary column. Chromatographic separation of a phenol mixture was demonstrated using the dual-detector system, with each detector producing a unique chromatogram. Less than 6% variation in the ratios of absorbances measured at the two wavelengths for specific analytes was obtained across 3 orders of magnitude concentration, which demonstrates the potential of using absorption ratio measurements for target analyte detection. The dual-detector system was used for simple, but accurate, mobile phase flow rate measurement at the exit of the column. With a flow rate range from 200 to 2000nL/min, less than 3% variation was observed. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Dynamic range considerations for EUV MAMA detectors. [Extreme UV Multianode Microchannel Array

    NASA Technical Reports Server (NTRS)

    Illing, Rainer M. E.; Bybee, Richard L.; Timothy, J. G.

    1990-01-01

    The multianode microchannel array (MAMA) has been chosen as the detector for two instruments on the ESA/NASA Solar Heliospheric Observatory. The response of the MAMA to the two extreme types of solar spectra, disk and corona, have been modeled with a view toward evaluating dynamic range effects present. The method of MAMA operation is discussed, with emphasis given to modeling the effect of electron cloud charge spreading to several detector anodes and amplifiers (n-fold events). Representative synthetic EUV spectra have been created. The detector response to these spectra is modeled by dissecting the input photon radiation field across the detector array into contributions to the various amplifier channels. The results of this dissection are shown for spectral regions across the entire wavelength region of interest. These results are used to identify regions in which total array photon counting rate or individual amplifier rate may exceed the design limits. This allows the design or operational modes to be tailored to eliminate the problem areas.

  12. Modeling Illumination Conditions on the Moon: Applications to LRO-LAMP

    NASA Astrophysics Data System (ADS)

    Byron, B. D.; Mazarico, E. M.; Retherford, K. D.; Mandt, K. E.; Greathouse, T.; Gladstone, R.

    2017-12-01

    LRO-LAMP is a UV spectrograph which uses illumination from Lyman-α sky glow along with UV light from bright stars to image the dark, permanently shadowed regions (PSRs) of the lunar surface. Accurate modeling of this UV illumination is essential to creating albedo maps of the lunar surface, which can shed light on lunar regolith processes and help to constrain the distribution of water ice in polar PSRs. In this study, the variation in reflected intensity received by the LAMP detector was modeled for South Pole crater Amundsen using the illumination program IllumNG. Amundsen was chosen for study due to the PSR in its Northern side and its highly illuminated equator-facing slopes on the Southern wall. The model works by tracing a ray from each LAMP detector pixel along its boresight until the point where it intersects the lunar surface, and calculating the percentage of the total source flux visible above the horizon. In this study, the three main illumination sources used are the Sun, Interplanetary Lyman-α sky glow, and bright UV starlight in the On Band (130-155 nm) and Off Band (155-190 nm) wavelength ranges. The model also has the capability to calculate incident flux received at the surface, as well as intensity reflected from the surface and received by the LAMP detector along each boresight. The study found a noticeable variation in received intensity between six month stretches for the year of 2010. Over the period of January through July, about 6% more IPM Lyman-α flux was reflected from the surface of Amundsen than for July through December. For stellar flux in the On Band, a 13% difference in flux was reflected between the six month periods. In comparing the monthly intensity maps created by the model with LAMP measured monthly brightness maps, similar crater features are apparent. Though the model brightness is generally higher than the LAMP brightness, after accounting for albedo ( 0.05 for the South Pole region) the values are in closer agreement. In the future, inclusion of the model results during pipeline processing could enable better calibration and analysis of LAMP data.

  13. The Fabrication and Characterization of Ni/4H-SiC Schottky Diode Radiation Detectors with a Sensitive Area of up to 4 cm².

    PubMed

    Liu, Lin-Yue; Wang, Ling; Jin, Peng; Liu, Jin-Liang; Zhang, Xian-Peng; Chen, Liang; Zhang, Jiang-Fu; Ouyang, Xiao-Ping; Liu, Ao; Huang, Run-Hua; Bai, Song

    2017-10-13

    Silicon carbide (SiC) detectors of an Ni/4H-SiC Schottky diode structure and with sensitive areas of 1-4 cm² were fabricated using high-quality lightly doped epitaxial 4H-SiC material, and were tested in the detection of alpha particles and pulsed X-rays/UV-light. A linear energy response to alpha particles ranging from 5.157 to 5.805 MeV was obtained. The detectors were proved to have a low dark current, a good energy resolution, and a high neutron/gamma discrimination for pulsed radiation, showing the advantages in charged particle detection and neutron detection in high-temperature and high-radiation environments.

  14. Performance and Results for Quartz Detector for the SuperHMS Spectrometer at Hall C Jefferson Lab

    NASA Astrophysics Data System (ADS)

    Griego, Benjamin F., Jr.

    A quartz detector has been constructed to be part of the trigger system for the Super High Momentum Spectrometer (SHMS). The SHMS will play a pivotal role in carrying out the 12 -- GeV physics program at Hal -- C Jefferson Lab. The quartz hodoscope consists of twenty one fused silica bars. Each bar is 125 cm long, 5.5 cm wide, 2.5 cm thick, and is viewed by a UV -- sensitive PMT on each end. The quartz hodoscope's task is to provide a clean detection of charged particles, a high level of background suppression, and an accurate tracking efficiency determination. Initial test results of the quartz detectors which include light yield and position resolution will be presented.

  15. The role of melanin as protector against free radicals in skin and its role as free radical indicator in hair

    NASA Astrophysics Data System (ADS)

    Herrling, Thomas; Jung, Katinka; Fuchs, Jürgen

    2008-05-01

    Throughout the body, melanin is a homogenous biological polymer containing a population of intrinsic, semiquinone-like radicals. Additional extrinsic free radicals are reversibly photo-generated by UV and visible light. Melanin photochemistry, particularly the formation and decay of extrinsic radicals, has been the subject of numerous electron spin resonance (ESR) spectroscopy studies. Several melanin monomers exist, and the predominant monomer in a melanin polymer depends on its location within an organism. In skin and hair, melanin differs in content of eumelanin or pheomelanin. Its bioradical character and its susceptibility to UV irradiation makes melanin an excellent indicator for UV-related processes in both skin and hair. The existence of melanin in skin is strongly correlated with the prevention against free radicals/ROS generated by UV radiation. Especially in the skin melanin (mainly eumelanin) ensures the only natural UV protection by eliminating the generated free radicals/ROS. Melanin in hair can be used as a free radical detector for evaluating the efficacy of hair care products. The aim of this study was to investigate the suitability of melanin as protector of skin against UV generated free radicals and as free radical indicator in hair.

  16. LED deep UV source for charge management of gravitational reference sensors

    NASA Astrophysics Data System (ADS)

    Sun, Ke-Xun; Allard, Brett; Buchman, Saps; Williams, Scott; Byer, Robert L.

    2006-04-01

    Proof mass electrical charge management is an important functionality for the ST-7-LTP technology demonstration flight and for LISA. Photoemission for charge control is accomplished by using deep ultraviolet (UV) light to excite photoelectron emission from an Au alloy. The conventional UV source is a mercury vapour lamp. We propose and demonstrate charge management using a deep UV light emitting diode (LED) source. We have acquired selected AlGaN UV LEDs, characterized their performance and successfully used them to realize charge management. The UV LEDs emit at a 257 nm central wavelength with a bandwidth of ~12 nm. The UV power for a free-space LED is ~120 µW, and after fibre coupling is ~16 µW, more than sufficient for LISA applications. We have directly observed the LED UV light-induced photocurrent response from an Au photocathode and an Au-coated GRS/ST-7 proof mass. We demonstrated fast switching of UV LEDs and associated fast changes in photocurrent. This allows modulation and continuous discharge to meet stringent LISA disturbance reduction requirements. We propose and demonstrate AC charge management outside the gravitational wave signal band. Further, the megahertz bandwidth for UV LED switching allows for up to six orders of magnitude dynamic power range and a number of novel modes of operations. The UV LED based charge management system offers the advantages of small-size, lightweight, fibre-coupled operation with very low power consumption. Presented at 'Amaldi6', Poster 73, Space Detector, 6th Edoardo Almadi Conference on Gravitational Waves, 20-24 June 2005.

  17. Identification of phenanthrene derivatives in Aerides rosea (Orchidaceae) using the combined systems HPLC-ESI-HRMS/MS and HPLC-DAD-MS-SPE-UV-NMR.

    PubMed

    Cakova, Veronika; Urbain, Aurélie; Antheaume, Cyril; Rimlinger, Nicole; Wehrung, Patrick; Bonté, Frédéric; Lobstein, Annelise

    2015-01-01

    In our continued efforts to contribute to the general knowledge on the chemical diversity of orchids, we have decided to focus our investigations on the Aeridinae subtribe. Following our previous phytochemical study of Vanda coerulea, which has led to the identification of phenanthrene derivatives, a closely related species, Aerides rosea Lodd. ex Lindl. & Paxton, was chosen for investigation. To identify new secondary metabolites, and to avoid isolation of those already known, by means of the combined systems HPLC-DAD(diode-array detector) with high-resolution tandem mass spectrometry (HRMS/MS) and HPLC-DAD-MS-SPE(solid-phase extraction)-UV-NMR. A dereplication strategy was developed using a HPLC-DAD-HRMS/MS targeted method and applied to fractions from A. rosea stem extract. Characterisation of unknown minor compounds was then performed using the combined HPLC-DAD-MS-SPE-UV-NMR system. The dereplication method allowed the characterisation of four compounds (gigantol, imbricatin, methoxycoelonin and coelonin), previously isolated from Vanda coerulea stem extract. The analyses of two fractions permitted the identification of five additional minor constituents including one phenanthropyran, two phenanthrene and two dihydrophenanthrene derivatives. The full set of NMR data of each compound was obtained from microgram quantities. Nine secondary metabolites were characterised in A. rosea stems, utilising HPLC systems combined with high-resolution analytical systems. Two of them are newly described phenanthrene derivatives: aerosanthrene (5-methoxyphenanthrene-2,3,7-triol) and aerosin (3-methoxy-9,10-dihydro-2,5,7-phenanthrenetriol). Copyright © 2014 John Wiley & Sons, Ltd.

  18. Design of the NDUV detection circuit for the NO concentration of the vehicle exhaust emissions

    NASA Astrophysics Data System (ADS)

    Zhang, Kai; Zhang, Yujun; He, Ying; You, Kun; Gao, Yanwei; Chen, Chen; Liu, Guohua; He, Chungui; Lu, Yibing; Liu, Wenqing

    2016-10-01

    With the increasing number of vehicles, the harm from NO to the environment becomes more and more prominent. So the monitoring of the NO concentration of the vehicle exhaust emissions is very important to assess the emission levels. In this paper, the NO detection system designing for vehicle exhaust emissions based on the non-dispersive ultraviolet principle (NDUV) has been researched. The technical indexes of the two-way modulation UV signal detection circuit are discussed in detail. And then a precision detection circuit is designed, which is composed of a trans-impedance amplifier and a lock-in amplifier, with which the output of the UV photoelectric detector can be amplified to a suitable voltage range, and the DC noise of the pre-stage amplifier is effectively removed by the lock-in amplifier. An experimental system was set up to test the designed circuit. To ensure the consistency of the two channels, the method of exchange calibration was adopted in the test. It's drawn that the designed circuit is of high SNR, measuring accuracy and a large dynamic range from the test results. The NO concentration detection limit of vehicle emissions can reach 1ppm, and the detection precision is +/-15ppm.

  19. Estimation of simvastatin and cetirizine by RP-LC method: Application to freeze and thaw (FT) stability studies.

    PubMed

    Naveed, Safila; Usmanghani, Khan; Sana, Aisha; Ali, Huma; Zafar, Farya; Qamar, Fatima; Sarwer, Ghulam; Abbas, Sarah; Alam, M Tanweer; Shinwari, Muhammad Ibrar

    2018-01-01

    Sensitive, simple, reliable and rapid HPLC technique for the estimation of simvastatin (SMV) and cetirizine has been designed in this study. The chromatographic conditions were set using Shimadzu LC-10 AT VP pump, with UV detector (SPD-10 AV-VP). System integration was performed with CBM-102 (Bus Module). Partitioning of components was attained with pre-packed C-18 column of Purospher Star (5 μm, 250 x 4.6 mm) at ambient conditions. Injected volume of sample was 10 μl. Mobile phase was composed of 50:50 v/v ratio of Acetonitrile/water (pH 3.0 adjusted with ortho-phosphoric acid) having 2 ml/minutes rate of flow. Compounds were detected in UV region at 225 nm. Percent Recovery of simvastatin was observed in the range of 98-102%. All results were found in accept table range of specification. The projected method is consistent, specific, precise, and rapid, that can be employed to quantitate the SMV along with cetirizine HCl. It was estimated by 3 successive cycles of freeze and thaw stability. Results of FT samples were found within accept table limits the method was developed and validated in raw materials, bulk formulations and final drug products.

  20. Fast and broadband detector for laser radiation

    NASA Astrophysics Data System (ADS)

    Scorticati, Davide; Crapella, Giacomo; Pellegrino, Sergio

    2018-02-01

    We developed a fast detector (patent pending) based on the Laser Induced Transverse Voltage (LITV) effect. The advantage of detectors using the LITV effect over pyroelectric sensors and photodiodes for laser radiation measurements is the combination of an overall fast response time, broadband spectral acceptance, high saturation threshold to direct laser irradiation and the possibility to measure pulsed as well as cw-laser sources. The detector is capable of measuring the energy of single laser pulses with repetition frequencies up to the MHz range, adding the possibility to also measure the output power of cw-lasers. Moreover, the thermal nature of the sensor enables the capability to work in a broadband spectrum, from UV to THz as well as the possibility of operating in a broad-range (10-3-102 W/cm2 ) of incident average optical power densities of the laser radiation, without the need of adopting optical filters nor other precautions.

  1. Laboratory Measurement of the Brighter-fatter Effect in an H2RG Infrared Detector

    NASA Astrophysics Data System (ADS)

    Plazas, A. A.; Shapiro, C.; Smith, R.; Huff, E.; Rhodes, J.

    2018-06-01

    The “brighter-fatter” (BF) effect is a phenomenon—originally discovered in charge coupled devices—in which the size of the detector point-spread function (PSF) increases with brightness. We present, for the first time, laboratory measurements demonstrating the existence of the effect in a Hawaii-2RG HgCdTe near-infrared (NIR) detector. We use JPL’s Precision Projector Laboratory, a facility for emulating astronomical observations with UV/VIS/NIR detectors, to project about 17,000 point sources onto the detector to stimulate the effect. After calibrating the detector for nonlinearity with flat-fields, we find evidence that charge is nonlinearly shifted from bright pixels to neighboring pixels during exposures of point sources, consistent with the existence of a BF-type effect. NASAs Wide Field Infrared Survey Telescope (WFIRST) will use similar detectors to measure weak gravitational lensing from the shapes of hundreds of million of galaxies in the NIR. The WFIRST PSF size must be calibrated to ≈0.1% to avoid biased inferences of dark matter and dark energy parameters; therefore further study and calibration of the BF effect in realistic images will be crucial.

  2. Directly-deposited blocking filters for high-performance silicon x-ray detectors

    NASA Astrophysics Data System (ADS)

    Bautz, M.; Kissel, S.; Masterson, R.; Ryu, K.; Suntharalingam, V.

    2016-07-01

    Silicon X-ray detectors often require blocking filters to mitigate noise and out-of-band signal from UV and visible backgrounds. Such filters must be thin to minimize X-ray absorption, so direct deposition of filter material on the detector entrance surface is an attractive approach to fabrication of robust filters. On the other hand, the soft (E < 1 keV) X-ray spectral resolution of the detector is sensitive to the charge collection efficiency in the immediate vicinity of its entrance surface, so it is important that any filter layer is deposited without disturbing the electric field distribution there. We have successfully deposited aluminum blocking filters, ranging in thickness from 70 to 220nm, on back-illuminated CCD X-ray detectors passivated by means of molecular beam epitaxy. Here we report measurements showing that directly deposited filters have little or no effect on soft X-ray spectral resolution. We also find that in applications requiring very large optical density (> OD 6) care must be taken to prevent light from entering the sides and mounting surfaces of the detector. Our methods have been used to deposit filters on the detectors of the REXIS instrument scheduled to fly on OSIRIS-ReX later this year.

  3. Apparatuses and methods for detecting, identifying and quantitating radioactive nuclei and methods of distinguishing neutron stimulation of a radiation particle detector from gamma-ray stimulation of a detector

    DOEpatents

    Cole, Jerald D.; Drigert, Mark W.; Reber, Edward L.; Aryaeinejad, Rahmat

    2001-01-01

    In one aspect, the invention encompasses a method of detecting radioactive decay, comprising: a) providing a sample comprising a radioactive material, the radioactive material generating decay particles; b)providing a plurality of detectors proximate the sample, the detectors comprising a first set and a second set, the first set of the detectors comprising liquid state detectors utilizing liquid scintillation material coupled with photo tubes to generate a first electrical signal in response to decay particles stimulating the liquid scintillation material, the second set of the detectors comprising solid state detectors utilizing a crystalline solid to generate a second electrical signal in response to decay particles stimulating the crystalline solid; c) stimulating at least one of the detectors to generate at least one of the first and second electrical signals, the at least one of the first and second electrical signals being indicative of radioactive decay in the sample. In another aspect, the invention encompasses an apparatus for identifying and quantitating radioactive nuclei of a sample comprising radioactive material that decays to generate neutrons and high-energy .gamma.-rays.

  4. On induced-modifications in optical properties of Makrofol® DE 1-1 SSNTD by UVB and UVA

    NASA Astrophysics Data System (ADS)

    Al-Amri, A.; El Ghazaly, M.; Abdel-Aal, M. S.

    The induced modifications in the optical properties of Makrofol® DE 1-1 solid state nuclear track detectors upon irradiation by UVB (302 nm) and UVA (365 nm) were characterized and compared. Makrofol® DE 1-1 detectors were irradiated separately for different durations with UVB (302 nm) and UVA (365 nm). The measurements revealed insignificant changes were observed at all in UVA (365 nm)-irradiated Makrofol® DE 1-1, irrespective the irradiation time (dose). All UVB (302 nm)-irradiated Makrofol® DE 1-1 detectors show a substantial red shift in UV-Vis spectra and a continuous increase in absorbance as the exposure time (Dose) to UVB increases. UVC-irradiated Makrofol® DE 1-1 exhibits absorption bands at 315 ± 5 nm in UV-visible spectra. The absorption increases exponential with the increasing the UVB irradiation time gets saturated started from 75 h to 400 h. In the visible light range no significant changes were observed in Makrofol® DE 1-1 detector irrespective the exposure time to UVB of 302 nm. It is found that the direct band gap is higher than indirect band gap and both decrease with the increase in the irradiation time of UVB of 302 nm. The obtained results of the Urbach energy and carbon atoms per cluster indicate that both increase with the increase in the irradiation time to UVB (302 nm). The induced modification in the optical properties of Makrofol® DE 1-1 can be used in UVB dosimetry, meanwhile it is not applicable for UVA of 365 nm.

  5. Crystal growth and characterization of europium doped lithium strontium iodide scintillator as an ionizing radiation detector

    NASA Astrophysics Data System (ADS)

    Uba, Samuel

    High performance detectors used in the detection of ionizing radiation is critical to nuclear nonproliferation applications and other radiation detectors applications. In this research we grew and tested Europium doped Lithium Strontium Iodide compound. A mixture of lithium iodide, strontium iodide and europium iodide was used as the starting materials for this research. Congruent melting and freezing temperature of the synthesized compound was determined by differential scanning calorimetry (DSC) using a Setaram Labsys Evo DSC-DTA instrument. The melting temperatures were recorded at 390.35°C, 407.59°C and freezing temperature was recorded at 322.84°C from a graph of heat flow plotted against temperature. The synthesized material was used as the charge for the vertical Bridgeman growth, and a 6.5 cm and 7.7cm length boule were grown in a multi-zone transparent Mullen furnace. A scintillating detector of thickness 2.53mm was fabricated by mechanical lapping in mineral oil, and scintillating response and timing were obtained to a cesium source using CS-137 isotope. An energy resolution (FWHM over peak position) of 12.1% was observed for the 662keV full absorption peak. Optical absorption in the UV-Vis wavelength range was recorded for the grown crystal using a U-2900 UV/VIS Spectrophotometer. Absorption peaks were recorded at 194nm, 273nm, and 344nm from the absorbance spectrum, various optical parameters such as absorption coefficient, extinction coefficient, refractive index, and optical loss were derived. The optical band gap energy was calculated using Tauc relation expression at 1.79eV.

  6. Starting A New Project: Thoughts from NGST

    NASA Technical Reports Server (NTRS)

    Mather, John C.; Oegerle, William (Technical Monitor)

    2002-01-01

    Some key elements of the history of NGST (Next Generation Space Telescope) that made a new mission possible will be reviewed, from the very beginnings to the present moment in the middle of selecting a prime contractor. A few forecasts of the possible discoveries will be made that may precede the launch of a new UV telescope, in hopes of inspiring sufficiently ambitious goals that they will still be exciting in 15 or 20 years. We will also discuss the enabling technology for NGST and my thoughts on enabling technology for a UV telescope Flint: they are not all about detectors and Mirrors!

  7. DETERMINATION OF CARBOXYLIC ACIDS BY ION-EXCLUSION CHROMATOGRAPHY WITH NON-SUPPRESSED CONDUCTIVITY AND OPTICAL DETECTORS

    EPA Science Inventory

    Determination of carboxylic acids using non-suppressed conductivity and UV detections is described. The background conductance of 1-octanesulfonic acid, hexane sulfonic acid and sulfuric acid at varying concentrations was determined. Using 0.2 mM 1-octanesulfonic acid as a mobile...

  8. Composition and stability of phytochemicals in five varieties of black soybeans (glycine max)

    USDA-ARS?s Scientific Manuscript database

    Phytochemical compositions of five varieties of black soybeans (Glycine max) and their stabilities at room temperature, 4 deg.C and -80 deg.C over 14 months were determined by HPLC systems with electrochemical (HPLC-ECD) and UV detectors. Polyphenol profiling was carried out by liquid chromatography...

  9. Reduction of Microbial Contaminants in Drinking Water by Ultraviolet Light Technology: ETS UV MODEL UVL-200-4 (Report and Statement)

    EPA Science Inventory

    Final technical report provides test methods used and verification results to be published on ETV web sites. The ETS UV System Model UVL-200-4 was tested to validate the UV dose delivered by the system using biodosimetry and a set line approach. The set line for 40 mJ/cm2 Red...

  10. Multi-particle inspection using associated particle sources

    DOEpatents

    Bingham, Philip R.; Mihalczo, John T.; Mullens, James A.; McConchie, Seth M.; Hausladen, Paul A.

    2016-02-16

    Disclosed herein are representative embodiments of methods, apparatus, and systems for performing combined neutron and gamma ray radiography. For example, one exemplary system comprises: a neutron source; a set of alpha particle detectors configured to detect alpha particles associated with neutrons generated by the neutron source; neutron detectors positioned to detect at least some of the neutrons generated by the neutron source; a gamma ray source; a set of verification gamma ray detectors configured to detect verification gamma rays associated with gamma rays generated by the gamma ray source; a set of gamma ray detectors configured to detect gamma rays generated by the gamma ray source; and an interrogation region located between the neutron source, the gamma ray source, the neutron detectors, and the gamma ray detectors.

  11. FIREBALL-2: Pioneering Space UV Baryon Mapping (Lead Institution)

    NASA Astrophysics Data System (ADS)

    Schiminovich, David

    This is the lead proposal of a multi-institutional submission. The Faint Intergalactic-medium Redshifted Emission Balloon (FIREBall-2) is designed to discover and map faint emission from the Intergalactic Medium (IGM) for low redshift galaxies. This balloon is a modification of FIREBall-1 (FB-1), a path-finding mission built by our team with two successful flights. FB-1 provided the strongest constrains on IGM emission available from any instrument at the time. FIREBall-2 has been significantly upgraded compared to FB-1, and is nearly ready for integration and testing before an anticipated Spring 2016 launch from Ft. Sumner, New Mexico. The spectrograph has been redesigned and an upgraded detector system including a groundbreaking high QE, low-noise, UV CCD detector is under final testing and will improve instrument performance by more than an order of magnitude. CNES is providing the spectrograph, gondola, and flight support team, with construction of all components nearly complete. The initial FIREBall-2 launch is now scheduled for Spring 2016. FIREBall-2 combines several innovations: -First ever multi-object UV spectrograph -Arcsecond quality balloon pointing system, developed from scratch, improved from FB-1 -Partnership of national space agencies (NASA & CNES); highly leveraged NASA resources -A Schmidt corrector built into the UV grating for better optical performance and throughput -A total of four women trained in space experimental astrophysics, including 3 Columbia Ph.Ds. and 1 Caltech Ph.D. -A total of 7 graduate students trained on FIREBall-1 (3) and FIREBall-2 (4), with opportunities for more in future flights. FIREBall-2 will test key technologies and science strategies for a future mission to map IGM emission. Its flights will provide important training for the next generation of space astrophysicists working in UV instrumentation. Most importantly, FIREBall-2 will detect emission from the CGM of nearby galaxies, providing the first census of the density and kinematics of this material for low z galaxies and opening a new field of CGM science.

  12. Verification of the SENTINEL-4 Focal Plane Subsystem

    NASA Astrophysics Data System (ADS)

    Williges, C.; Hohn, R.; Rossmann, H.; Hilbert, S.; Uhlig, M.; Buchwinkler, K.; Reulke, R.

    2017-05-01

    The Sentinel-4 payload is a multi-spectral camera system which is designed to monitor atmospheric conditions over Europe. The German Aerospace Center (DLR) in Berlin, Germany conducted the verification campaign of the Focal Plane Subsystem (FPS) on behalf of Airbus Defense and Space GmbH, Ottobrunn, Germany. The FPS consists, inter alia, of two Focal Plane Assemblies (FPAs), one for the UV-VIS spectral range (305 nm … 500 nm), the second for NIR (750 nm … 775 nm). In this publication, we will present in detail the opto-mechanical laboratory set-up of the verification campaign of the Sentinel-4 Qualification Model (QM) which will also be used for the upcoming Flight Model (FM) verification. The test campaign consists mainly of radiometric tests performed with an integrating sphere as homogenous light source. The FPAs have mainly to be operated at 215 K ± 5 K, making it necessary to exploit a thermal vacuum chamber (TVC) for the test accomplishment. This publication focuses on the challenge to remotely illuminate both Sentinel-4 detectors as well as a reference detector homogeneously over a distance of approximately 1 m from outside the TVC. Furthermore selected test analyses and results will be presented, showing that the Sentinel-4 FPS meets specifications.

  13. Berkeley extreme-ultraviolet airglow rocket spectrometer: BEARS.

    PubMed

    Cotton, D M; Chakrabarti, S

    1992-09-20

    We describe the Berkeley extreme-UV airglow rocket spectrometer, which is a payload designed to test several thermospheric remote-sensing concepts by measuring the terrestrial O I far-UV and extreme-UV dayglow and the solar extreme-UV spectrum simultaneously. The instrument consisted of two near-normal Rowland mount spectrometers and a Lyman-alpha photometer. The dayglow spectrometer covered two spectral regions from 980 to 1040 A and from 1300 to 1360 A with 1.5-A resolution. The solar spectrometer had a bandpass of 250-1150 A with an ~ 10-A resolution. All three spectra were accumulated by using a icrochannel-plate-intensified, two-dimensional imaging detector with three separate wedge-and strip anode readouts. The hydrogen Lyman-alpha photometer was included to monitor the solar Lyman-alpha irradiance and geocoronal Lyman-alpha emissions. The instrument was designed, fabricated, and calibrated at the University of California, Berkeley and was successfully launched on 30 September 1988 aboard the first test flight of a four-stage sounding rocket, Black Brant XII.

  14. The Ultraviolet Spectrograph on NASA's Juno Mission

    NASA Astrophysics Data System (ADS)

    Gladstone, G. Randall; Persyn, Steven C.; Eterno, John S.; Walther, Brandon C.; Slater, David C.; Davis, Michael W.; Versteeg, Maarten H.; Persson, Kristian B.; Young, Michael K.; Dirks, Gregory J.; Sawka, Anthony O.; Tumlinson, Jessica; Sykes, Henry; Beshears, John; Rhoad, Cherie L.; Cravens, James P.; Winters, Gregory S.; Klar, Robert A.; Lockhart, Walter; Piepgrass, Benjamin M.; Greathouse, Thomas K.; Trantham, Bradley J.; Wilcox, Philip M.; Jackson, Matthew W.; Siegmund, Oswald H. W.; Vallerga, John V.; Raffanti, Rick; Martin, Adrian; Gérard, J.-C.; Grodent, Denis C.; Bonfond, Bertrand; Marquet, Benoit; Denis, François

    2017-11-01

    The ultraviolet spectrograph instrument on the Juno mission (Juno-UVS) is a long-slit imaging spectrograph designed to observe and characterize Jupiter's far-ultraviolet (FUV) auroral emissions. These observations will be coordinated and correlated with those from Juno's other remote sensing instruments and used to place in situ measurements made by Juno's particles and fields instruments into a global context, relating the local data with events occurring in more distant regions of Jupiter's magnetosphere. Juno-UVS is based on a series of imaging FUV spectrographs currently in flight—the two Alice instruments on the Rosetta and New Horizons missions, and the Lyman Alpha Mapping Project on the Lunar Reconnaissance Orbiter mission. However, Juno-UVS has several important modifications, including (1) a scan mirror (for targeting specific auroral features), (2) extensive shielding (for mitigation of electronics and data quality degradation by energetic particles), and (3) a cross delay line microchannel plate detector (for both faster photon counting and improved spatial resolution). This paper describes the science objectives, design, and initial performance of the Juno-UVS.

  15. [Application of asymmetrical flow field-flow fractionation for size characterization of low density lipoprotein in egg yolk plasma].

    PubMed

    Zhang, Wenhui; Cai, Chunxue; Wang, Jing; Mao, Zhen; Li, Yueqiu; Ding, Liang; Shen, Shigang; Dou, Haiyang

    2017-08-08

    Home-made asymmetrical flow field-flow fractionation (AF4) system, online coupled with ultraviolet/visible (UV/Vis) detector was employed for the separation and size characterization of low density lipoprotein (LDL) in egg yolk plasma. At close to natural condition of egg yolk, the effects of cross flow rate, sample loading, and type of membrane on the size distribution of LDL were investigated. Under the optimal operation conditions, AF4-UV/Vis provides the size distribution of LDL. Moreover, the precision of AF4-UV/Vis method proposed in this work for the analysis of LDL in egg yolk plasma was evaluated. The intra-day precisions were 1.3% and 1.9% ( n =7) and the inter-day precisions were 2.4% and 2.3% ( n =7) for the elution peak height and elution peak area of LDL, respectively. Results reveal that AF4-UV/Vis is a useful tool for the separation and size characterization of LDL in egg yolk plasma.

  16. Imaging on a Shoestring: Cost-Effective Technologies for Probing Vadose Zone Transport Processes

    NASA Astrophysics Data System (ADS)

    Corkhill, C.; Bridge, J. W.; Barns, G.; Fraser, R.; Romero-Gonzalez, M.; Wilson, R.; Banwart, S.

    2010-12-01

    Key barriers to the widespread uptake of imaging technology for high spatial resolution monitoring of porous media systems are cost and accessibility. X-ray tomography, magnetic resonance imaging (MRI), gamma and neutron radiography require highly specialised equipment, controlled laboratory environments and/or access to large synchrotron facilities. Here we present results from visible light, fluorescence and autoradiographic imaging techniques developed at low cost and applied in standard analytical laboratories, adapted where necessary at minimal capital expense. UV-visible time lapse fluorescence imaging (UV-vis TLFI) in a transparent thin bed chamber enabled microspheres labelled with fluorescent dye and a conservative fluorophore solute (disodium fluorescein) to be measured simultaneously in saturated, partially-saturated and actively draining quartz sand to elucidate empirical values for colloid transport and deposition parameters distributed throughout the flow field, independently of theoretical approximations. Key results include the first experimental quantification of the effects of ionic strength and air-water interfacial area on colloid deposition above a capillary fringe, and the first direct observations of particle mobilisation and redeposition by moving saturation gradients during drainage. UV-vis imaging was also used to study biodegradation and reactive transport in a variety of saturated conditions, applying fluorescence as a probe for oxygen and nitrate concentration gradients, pH, solute transport parameters, reduction of uranium, and mapping of two-dimensional flow fields around a model dipole flow borehole system to validate numerical models. Costs are low: LED excitation sources (< US 50), flow chambers (US 200) and detectors (although a complete scientific-grade CCD set-up costs around US$ 8000, robust datasets can be obtained using a commercial digital SLR camera) mean that set-ups can be flexible to meet changing experimental requirements. The critical limitations of UV-vis fluorescence imaging are the need for reliable fluorescent probes suited to the experimental objective, and the reliance on thin-bed (2D) transparent porous media. Autoradiographic techniques address some of these limitations permit imaging of key biogeochemical processes in opaque media using radioactive probes, without the need for specialised radiation sources. We present initial calibration data for the use of autoradiography to monitor transport parameters for radionuclides (99-technetium), and a novel application of a radioactive salt tracer as a probe for pore water content, in model porous media systems.

  17. Rapid analysis of clenbuterol, salbutamol, procaterol, and fenoterol in pharmaceuticals and human urine by capillary electrophoresis.

    PubMed

    Sirichai, Somsak; Khanatharana, Proespichaya

    2008-09-15

    Capillary electrophoresis (CE) with UV detection for the simultaneous and short-time analysis of clenbuterol, salbutamol, procaterol, fenoterol is described and validated. Optimized conditions were found to be a 10 mmoll(-1) borate buffer (pH 10.0), an separation voltage of 19 kV, and a separation temperature of 32 degrees C. Detection was set at 205 nm. Under the optimized conditions, analyses of the four analytes in pharmaceutical and human urine samples were carried out in approximately 1 min. The interference of the sample matrix was not observed. The LOD (limits of detection) defined at S/N of 3:1 was found between 0.5 and 2.0 mgl(-1) for the analytes. The linearity of the detector response was within the range from 2.0 to 30 mgl(-1) with correlation coefficient >0.996.

  18. Direct observation of spin-resolved full and empty electron states in ferromagnetic surfaces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berti, G., E-mail: giulia.berti@polimi.it; Calloni, A.; Brambilla, A.

    2014-07-15

    We present a versatile apparatus for the study of ferromagnetic surfaces, which combines spin-polarized photoemission and inverse photoemission spectroscopies. Samples can be grown by molecular beam epitaxy and analyzed in situ. Spin-resolved photoemission spectroscopy analysis is done with a hemispherical electron analyzer coupled to a 25 kV-Mott detector. Inverse photoemission spectroscopy experiments are performed with GaAs crystals as spin-polarized electron sources and a UV bandpass photon detector. As an example, measurements on the oxygen passivated Fe(100)-p(1×1)O surface are presented.

  19. A Prototype Combination TPC Cherenkov Detector with GEM Readout for Tracking and Particle Identification and its Potential Use at an Electron Ion Collider

    NASA Astrophysics Data System (ADS)

    Woody, Craig; Azmoun, Babak; Majka, Richard; Phipps, Michael; Purschke, Martin; Smirnov, Nikolai

    2018-02-01

    A prototype detector is being developed which combines the functions of a Time Projection Chamber for charged particle tracking and a Cherenkov detector for particle identification. The TPC consists of a 10×10×10 cm3 drift volume where the charge is drifted to a 10×10 cm2 triple GEM detector. The charge is measured on a readout plane consisting of 2×10 mm2 chevron pads which provide a spatial resolution ˜ 100 μm per point in the chevron direction along with dE/dx information. The Cherenkov portion of the detector consists of a second 10×10 cm2 triple GEM with a photosensitive CsI photocathode on the top layer. This detector measures Cherenkov light produced in the drift gas of the TPC by high velocity particles which are above threshold. CF4 or CF4 mixtures will be used as the drift gas which are highly transparent to UV light and can provide excellent efficiency for detecting Cherenkov photons. The drift gas is also used as the operating gas for both GEM detectors. The prototype detector has been constructed and is currently being tested in the lab with sources and cosmic rays, and additional tests are planned in the future to study the detector in a test beam.

  20. Combined FDTD-Monte Carlo analysis and a novel design for ZnO scintillator rods in polycarbonate membrane for X-ray imaging

    NASA Astrophysics Data System (ADS)

    Mohammadian-Behbahani, Mohammad-Reza; Saramad, Shahyar; Mohammadi, Mohammad

    2017-05-01

    A combination of Finite Difference Time Domain (FDTD) and Monte Carlo (MC) methods is proposed for simulation and analysis of ZnO microscintillators grown in polycarbonate membrane. A planar 10 keV X-ray source irradiating the detector is simulated by MC method, which provides the amount of absorbed X-ray energy in the assembly. The transport of generated UV scintillation light and its propagation in the detector was studied by the FDTD method. Detector responses to different probable scintillation sites and under different energies of X-ray source from 10 to 25 keV are reported. Finally, the tapered geometry for the scintillators is proposed, which shows enhanced spatial resolution in comparison to cylindrical geometry for imaging applications.

  1. Characterization of Pr:LuAG scintillating crystals for X-ray spectroscopy

    NASA Astrophysics Data System (ADS)

    Bertoni, R.; Bonesini, M.; Cervi, T.; Clemenza, M.; De Bari, A.; Falcone, A.; Mazza, R.; Menegolli, A.; Nastasi, M.; Rossella, M.

    2016-07-01

    The main features of the Pr doped Lu3Al5O12 (Pr:LuAG) scintillating crystals for X-ray spectroscopy applications have been studied using different radioactive sources and photo-detectors. Pr:LuAG is cheaper, compared to a Germanium detector, but with remarkable properties which make it useful for many applications, from fundamental physics measurements to the PET imaging for medical purposes: high density, elevate light yield, fast response, high energy resolution, no hygroscopicity. A sample of Pr:LuAG crystals with 14 mm×14 mm surface area and 13 mm thickness and a NaI crystal of the same surface and 26 mm thickness used as a reference have been characterized with several radioactive sources, emitting photons in the range 100-1000keV. Different light detectors were adopted for the Pr:LuAG studies, sensitive to its UV emission (peak at 310 nm): a 3 in. PMT (Hamamatsu R11065) and new arrays of Hamamatsu SiPM S13361, with siliconic resin as a window. Preliminary results are presented on the performance of the Pr:LuAG crystals, to be mounted in a 2 × 2 array to be tested in the 2015 run of the FAMU experiment at RIKEN-RAL muon facility. The goal is the detection of the X-rays (around 130 keV) emitted during the de-excitation processes of the muonic hydrogen after the excitation with an IR laser with wavelength set at the resonance of the hyperfine splitting, to measure the muonic atom proton radius with unprecedented precision.

  2. Set of instruments for solar EUV and soft X-ray monitoring onboard satellite Coronas-Photon

    NASA Astrophysics Data System (ADS)

    Kotov, Yury; Kochemasov, Alexey; Kuzin, Sergey; Kuznetsov, Vladimir; Sylwester, Janusz; Yurov, Vitaly

    Coronas-Photon mission is the third satellite of the Russian Coronas program on solar activity observation. The main goal of the "Coronas-Photon" is the study of solar hard electromagnetic radiation in the wide energy range from UV up to high energy gamma-radiation (2000MeV). Scientific payload for solar radiation observation consists of three types of instruments: Monitors (Natalya-2M, Konus-RF, RT-2, Penguin-M, BRM, PHOKA, Sphin-X, SOKOL spectral and timing measurements of full solar disk radiation have timing in flare/burst mode up to one msec. Instruments Natalya-2M, Konus-RF, RT-2 will cover the wide energy range of hard X-rays and soft gamma-rays (15keV to 2000MeV) and will together constitute the largest area detectors ever used for solar observations. Detectors of gamma-ray monitors are based on structured inorganic scintillators. For X-ray and EUV monitors the scintillation phoswich detectors, gas proportional counter, CdZnTe assembly and filter-covered Si-diodes are used. Telescope-spectrometer TESIS for imaging solar spectroscopy in X-rays has angular resolution up to 1arcsec in three spectral lines. Satellite platform and scientific payload is under construction to be launched in autumn 2008. Satellite orbit is circular with initial height 550km and inclination 82.5degrees. Accuracy of the spacecraft orientation to the Sun is better 3arcmin. In the report the capability of PHOKA, SphinX, SOKOL and TESIS as well as the observation program are described and discussed.

  3. Solution-processed nanoparticle super-float-gated organic field-effect transistor as un-cooled ultraviolet and infrared photon counter.

    PubMed

    Yuan, Yongbo; Dong, Qingfeng; Yang, Bin; Guo, Fawen; Zhang, Qi; Han, Ming; Huang, Jinsong

    2013-01-01

    High sensitivity photodetectors in ultraviolet (UV) and infrared (IR) range have broad civilian and military applications. Here we report on an un-cooled solution-processed UV-IR photon counter based on modified organic field-effect transistors. This type of UV detectors have light absorbing zinc oxide nanoparticles (NPs) sandwiched between two gate dielectric layers as a floating gate. The photon-generated charges on the floating gate cause high resistance regions in the transistor channel and tune the source-drain output current. This "super-float-gating" mechanism enables very high sensitivity photodetectors with a minimum detectable ultraviolet light intensity of 2.6 photons/μm(2)s at room temperature as well as photon counting capability. Based on same mechansim, infrared photodetectors with lead sulfide NPs as light absorbing materials have also been demonstrated.

  4. Charge management for gravitational-wave observatories using UV LEDs

    NASA Astrophysics Data System (ADS)

    Pollack, S. E.; Turner, M. D.; Schlamminger, S.; Hagedorn, C. A.; Gundlach, J. H.

    2010-01-01

    Accumulation of electrical charge on the end mirrors of gravitational-wave observatories can become a source of noise limiting the sensitivity of such detectors through electronic couplings to nearby surfaces. Torsion balances provide an ideal means for testing gravitational-wave technologies due to their high sensitivity to small forces. Our torsion pendulum apparatus consists of a movable plate brought near a plate pendulum suspended from a nonconducting quartz fiber. A UV LED located near the pendulum photoejects electrons from the surface, and a UV LED driven electron gun directs photoelectrons towards the pendulum surface. We have demonstrated both charging and discharging of the pendulum with equivalent charging rates of ˜105e/s, as well as spectral measurements of the pendulum charge resulting in a white noise level equivalent to 3×105e/Hz.

  5. Optical and UV Sensing Sealed Tube Microchannel Plate Imaging Detectors with High Time Resolution

    NASA Astrophysics Data System (ADS)

    Siegmund, O.; Vallerga, J.; Tremsin, A.; Hull, J.; Elam, J.; Mane, A.

    2014-09-01

    Microchannel plate (MCP) based imaging, photon time tagging detector sealed tube schemes have a unique set of operational features that enable high time resolution astronomical and remote sensing applications to be addressed. New detectors using the cross strip (XS), cross delay line (XDL), or stripline anode readouts, a wide range of photocathode types, and advanced MCP technologies have been implemented to improve many performance characteristics. A variety of sealed tubes have been developed including 18mm XS readout devices with GaAs and SuperGenII photocathodes, 25mm XDL readout devices with SuperGenII and GaN photocathodes, and 20 x 20 cm sealed tubes with bialkali photocathodes and strip line readout. One key technology that has just become viable is the ability to make MCPs using atomic layer deposition (ALD) techniques. This employs nanofabrication of the active layers of an MCP on a microcapillary array. This technique opens new performance opportunities, including, very large MCP areas (>20cm), very low intrinsic background, lower radiation induced background, much longer overall lifetime and gain stability, and markedly lower outgassing which can improve the sealed tube lifetime and ease of fabrication. The XS readout has been implemented in formats of 22mm, 50mm and 100mm, and uses MCP charge signals detected on two orthogonal layers of conductive fingers to encode event X-Y positions. We have achieved spatial resolution XS detectors better than 25 microns FWHM, with good image linearity while at low gain (<10^6), substantially increasing local counting rate capabilities and the overall tube lifetime. XS tubes with updated electronics can encode event rates of >5 MHz with ~12% dead time and event timing accuracy of ~100ps. XDL sealed tubes in 25mm format demonstrate ~40 micron spatial resolution at up to ~2 MHz event rates, and have been developed with SupergenII visible regime photocathodes. The XDL tubes also achieve ~100 ps time resolution. Most recently ALD MCPs with an opaque GaN photocathode (100-350nm range) on the MCP surface has been demonstrated in a sealed tube configuration. These ALD MCPs show a stable and permanent 10x gain increase during tube processing. Efforts are also underway to establish ALD MCP configurations with large area sealed tubes from 5cm up to 20cm in size. We will discuss these efforts and their performance characteristics. We will discuss how we are applying these detector system developments to a number of applications. This includes ground based instruments for observations of transient and variable astronomical objects, as well as implementation in satellite instruments for earth atmospheric and solar observations. The XS 18mm sealed tube detectors are being implemented for night time remote reconnaissance and biological single-molecule fluorescence lifetime imaging microscopy. Related efforts also include development of large (20cm) sealed tubes for Cherenkov light detection and large area focal plane imagers, and GaN sealed tube devices are candidates for future astronomical space based UV imaging and spectroscopy.

  6. Distribution and nature of UV absorbers on Trition's surface

    NASA Technical Reports Server (NTRS)

    Stern, S. Alan

    1995-01-01

    Substantial evidence suggests that a UV (ultraviolet) Spectrally Absorbing Material (UV-SAM) exists on Triton's surface. This evidence is found in the positive slope in Triton's spectrum from the UV to the near-IR, and the increasing contrast in Triton's light curve in the blue and UV. Although it is now widely-thought that UV-SAM's exist on Triton, little is known about their distribution and spectral properties. The goal of this NDAP Project is to determine the spatial distribution and geological context of the UV-SAM material. We hope to determine if UV-SAM's on Triton are correlated with geologic wind streaks, craters, calderas, geomorphic/topographic units, regions containing (or lacking) volatile frosts, or some other process (e.g., magnetospheric interactions). Once the location and distribution of UV-SAM's has been determined, further constraints on their composition can be made by analyzing the spectrographic data set. To accomplish these goals, various data sets will be used, including Voyager 2 UV and visible images of Triton's surface, IUE and HST spectra of Triton, and a geologic map of the surface based on Voyager 2 and spectrophotometric data. The results of this research will be published in the planetary science literature.

  7. Distribution and nature of UV absorbers on Triton's surface

    NASA Technical Reports Server (NTRS)

    Stern, S. Alan

    1995-01-01

    Substantial evidence suggests that a UV spectrally Absorbing Material (UV-SAM) exists on Triton's surface. This evidence is found in the positive slope in Triton's spectrum from the UV to the near-IR, and the increasing contrast in Triton's light curve in the blue and UV. Although it is now widely-thought that UV-SAMs exist on Triton, little is known about their distribution and spectral properties. The goal of this NDAP Project is to determine the spatial distribution and geological context of the UV-SaM material. We hope to determine if UV-SAMs on Triton are correlated with geologic wind streaks, craters, calderas, geomorphic/topographic units, regions containing (or lacking) volatile frosts, or some other process (e.g., magnetospheric interactions). Once the location and distribution of UV-SAMs has been determined, further constraints on their composition cable made by analyzing the spectrographic data set. To accomplish these goals, various data sets will be used, including Voyager 2 UV and visible images of Triton's surface, IUE and HST spectra of Triton, and a geologic map of the surface based on voyager 2 and spectrophotometric data. The results of this research will be published in the planetary science literature.

  8. Distribution and nature of UV absorbers on Triton's surface

    NASA Technical Reports Server (NTRS)

    Stern, S. Alan

    1994-01-01

    Substantial evidence suggests that a UV Spectrally Absorbing Material (UV-SAM) exists on Triton's surface. This evidence is found in the positive slope in Triton's spectrum from the UV to the near-IR, and the increasing contrast in Triton's light curve in the blue and UV. Although it is now widely-thought that UV-SAM's exist on Triton, little is known about their distribution and spectral properties. The goal of this NDAP Project is to determine the spatial distribution and geological context of the UV-SAM material. We hope to determine if UV-SAM's on Triton are correlated with geologic wind streaks, craters, calderas, geomorphic/topographic units, regions containing (or lacking) volatile frosts, or some other process (e.g., magnetospheric interactions). Once the location and distribution of UV-SAM's has been determined, further constraints on their composition can be made by analyzing the spectrographic data set. To accomplish these goals, various data sets will be used, including Voyager 2 UV and visible images of Triton's surface, IUE and HST spectra of Triton, and a geologic map of the surface based on Voyager 2 and spectrophotometric data. The results of this research will be published in the planetary science literature.

  9. Visible-Blind UV Photodetector Based on Single-Walled Carbon Nanotube Thin Film/ZnO Vertical Heterostructures.

    PubMed

    Li, Guanghui; Suja, Mohammad; Chen, Mingguang; Bekyarova, Elena; Haddon, Robert C; Liu, Jianlin; Itkis, Mikhail E

    2017-10-25

    Ultraviolet (UV) photodetectors based on heterojunctions of conventional (Ge, Si, and GaAs) and wide bandgap semiconductors have been recently demonstrated, but achieving high UV sensitivity and visible-blind photodetection still remains a challenge. Here, we utilized a semitransparent film of p-type semiconducting single-walled carbon nanotubes (SC-SWNTs) with an energy gap of 0.68 ± 0.07 eV in combination with a molecular beam epitaxy grown n-ZnO layer to build a vertical p-SC-SWNT/n-ZnO heterojunction-based UV photodetector. The resulting device shows a current rectification ratio of 10 3 , a current photoresponsivity up to 400 A/W in the UV spectral range from 370 to 230 nm, and a low dark current. The detector is practically visible-blind with the UV-to-visible photoresponsivity ratio of 10 5 due to extremely short photocarrier lifetimes in the one-dimensional SWNTs because of strong electron-phonon interactions leading to exciton formation. In this vertical configuration, UV radiation penetrates the top semitransparent SC-SWNT layer with low losses (10-20%) and excites photocarriers within the n-ZnO layer in close proximity to the p-SC-SWNT/n-ZnO interface, where electron-hole pairs are efficiently separated by a high built-in electric field associated with the heterojunction.

  10. The enhancement of biological ocular UV radiation on beaches compared to the radiation on grass.

    PubMed

    Liu, Guang-Cong; Wang, Fang; Gao, Yan-Yan; Yang, Zheng; Hu, Li-Wen; Gao, Qian; Ri, Jun-Chol; Liu, Yang

    2014-12-01

    The influence of albedo on ocular UV exposure has seldom been reported. This paper aimed to explore the enhancement effect on measured ocular UV radiation due to a sand surface compared to measured ocular UV radiation due to a grass surface. We measured ambient and ocular UV radiation over the beach and grass surface in Sanya City of China (18.4°N, 109.7°E). The experimental apparatus was composed of a manikin and a dual-detector spectrometer. Integration of both UVA and UVB radiation was used to denote UV radiation. Then biologically effective ocular UVB radiation (UVBE) and the ratios of UVBE of two surfaces were calculated. Maximum of ocular UV radiation versus time over the two surfaces is bimodal. UVBE on the beach is significantly larger than UVBE on the sand, and UVBE peaked at different solar elevation angle (SEA) over the two surfaces (about 53° and 40° on the beach and grass, respectively, according to Bayesian regression). The maximum of ocular UVBE ratios is greater than two, which peaked SEA was about 50°. One hour's cumulative radiation under sunny weather exceeds thresholds for photokeratitis, conjunctivitis and lens damage. Higher albedo significantly increased biological ocular UV radiation. Tourists on tropical beaches should take protective measures and avoid facing the sun directly, especially when SEA is around 50°. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. DETERMINATION OF CARBENDAZIM IN WATER BY HIGH-PERFORMANCE IMMUNOAFFINITY CHROMATOGRAPHY ON-LINE WITH HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY WITH DIODE-ARRAY OR MASS SPECTROMETRIC DETECTION

    EPA Science Inventory

    An automated method for the determination of carbendazim in water that combines high-performance immunoaffinity chromatography (HPIAC), high-performance liquid chromatography (HPLC) in the reversed-phase mode, and detection by either UV-Vis diode array detector (DAD) spectroscopy...

  12. Exhaust Plume Measurements of 15-Pound BATES (Ballistic Test and Evaluation System) Motors.

    DTIC Science & Technology

    1985-06-01

    laser transmissometer measurements as a plume... System 7 3 AFRPL Laser Transmission/Scattering Measurement System During Motor Firing 8 4 Laser Scattering Detector Schematic 9 5 Laser Scattering... measurement goals. The instrumentation includes a multi -wavelength, single line-of-sight IR-E/A system , a UV emission spectrometer, an exhaust

  13. Development of novel UV emitting single crystalline film scintillators

    NASA Astrophysics Data System (ADS)

    Zorenko, Yu; Gorbenko, V.; Savchyn, V.; Voznyak, T.; Nikl, M.; Mares, J. A.; Martin, T.; Douissard, P.-A.

    2011-04-01

    The work is dedicated to development of new types of UV -emitting scintillators based on single crystalline films (SCF) of aluminimum perovskites and garnets grown by the liquid phase epitaxy (LPE) method. The development of the following three types of UV SCF scintillators is considered in this work: i) Ce-doped SCF of Y-Lu-Al-perovskites with Ce3+ emission in the 360-370 nm range with a decay time of 16-17 ns; ii) Pr-doped SCF of Y-Lu-Al garnets with Pr3+ emission in the 300-400 nm range with a decay time of 13-17 ns; iii) La3+ and Sc3+ doped SCF of Y-Lu-Al-garnets, emitting in the 290-400 nm range due to formation of the LaY,Lu, ScY,Lu and ScAl centers with decay time of 250-575 ns. The results of testing the several novel UV-emitting SCFs scintillators for visualization of X-ray images at ESFR are presented. It is shown that the UV emission of the LuAG:Sc, LuAG:La and LuAG:Pr SCFs is efficient enough for conversion of X-ray to the UV light and that these scintillators can be used for improvement of the resolution of imaging detectors in synchrotron radiation applications.

  14. Analysis of phenolic acids by ionic liquid-in-water microemulsion liquid chromatography coupled with ultraviolet and electrochemical detector.

    PubMed

    Peng, Li-Qing; Cao, Jun; Du, Li-Jing; Zhang, Qi-Dong; Shi, Yu-Tin; Xu, Jing-Jing

    2017-05-26

    An environmentally friendly ionic liquid-in-water (IL/W) microemulsion was established and applied as mobile phase in microemulsion liquid chromatography (MELC) with ultraviolet (UV) detection or electrochemical detector (ECD) for analysis of phenolic compounds in real samples. The optimal condition of the method was using the best composition of microemulsion (0.2% w/v [HMIM]PF 6 , 1.0% w/v SDS, 3.0% w/v n-butanol, 95.8% v/v water, pH 2.5) with UV detection. The validation results indicated that the method provided high degree of sensitivity, precision and accuracy with the low limit of detections ranged from 17.9-238ng/mL, satisfactory mean recovery values in the range of 80.1-105% and good linearity (r 2 >0.9994). Additionally, this method exhibited high selectivity and resolution for the analytes and was more eco-friendly compared with traditional MELC method. Consequently, the established IL/W MELC method was successfully applied to simultaneously separate and determine target compounds in Danshen sample and its preparation. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Ultratrace detector for hand-held gas chromatography

    DOEpatents

    Andresen, Brian D.; Miller, Fred S.

    1999-01-01

    An ultratrace detector system for hand-held gas chromatography having high sensitivity, for example, to emissions generated during production of weapons, biological compounds, drugs, etc. The detector system is insensitive to water, air, helium, argon, oxygen, and C0.sub.2. The detector system is basically composed of a hand-held capillary gas chromatography (GC), an insulated heated redox-chamber, a detection chamber, and a vapor trap. For example, the detector system may use gas phase redox reactions and spectral absorption of mercury vapor. The gas chromatograph initially separates compounds that percolate through a bed of heated mercuric oxide (HgO) in a silica--or other metal--aerogel material which acts as an insulator. Compounds easily oxidized by HgO liberate atomic mercury that subsequently pass through a detection chamber which includes a detector cell, such as quartz, that is illuminated with a 254 nm ultra-violet (UV) mercury discharge lamp which generates the exact mercury absorption bands that are used to detect the liberated mercury atoms. Atomic mercury strongly absorbs 254 nm energy is therefore a specific signal for reducing compounds eluting from the capillary GC, whereafter the atomic mercury is trapped for example, in a silicon-aerogel trap.

  16. SiC-based Photo-detectors for UV, VUV, EUV and Soft X-ray Detection

    NASA Technical Reports Server (NTRS)

    Yan, Feng

    2006-01-01

    A viewgraph presentation describing an ideal Silicon Carbide detector for ultraviolet, vacuum ultraviolet, extreme ultraviolet and soft x-ray detection is shown. The topics include: 1) An ideal photo-detector; 2) Dark current density of SiC photodiodes at room temperature; 3) Dark current in SiC detectors; 4) Resistive and capacitive feedback trans-impedance amplifier; 5) Avalanche gain; 6) Excess noise; 7) SNR in single photon counting mode; 8) Structure of SiC single photon counting APD and testing structure; 9) Single photon counting waveform and testing circuit; 10) Amplitude of SiC single photon counter; 11) Dark count of SiC APD photon counters; 12) Temperature-dependence of dark count rate; 13) Reduce the dark count rate by reducing the breakdown electric field; 14) Spectrum range for SiC detectors; 15) QE curves of Pt/4H-SiC photodiodes; 16) QE curve of SiC; 17) QE curves of SiC photodiode vs. penetration depth; 18) Visible rejection of SiC photodiodes; 19) Advantages of SiC photodiodes; 20) Competitors of SiC detectors; 21) Extraterrestrial solar spectra; 22) Visible-blind EUV detection; 23) Terrestrial solar spectra; and 24) Less than 1KeV soft x-ray detection.

  17. Progress in the development of a S-RETGEM-based detector for an early forest fire warning system

    NASA Astrophysics Data System (ADS)

    Charpak, G.; Benaben, P.; Breuil, P.; Martinengo, P.; Nappi, E.; Peskov, V.

    2009-12-01

    We present a prototype of a Strip Resistive Thick GEM (S-RETGEM) photosensitive gaseous detector filled with Ne and ethylferrocene (EF) vapours at a total pressure of 1 atm for an early forest fire detection system. Measurements show that it is one hundred times more sensitive than the best commercial ultraviolet (UV) flame detectors; and therefore, it is able to reliably detect a flame of ~ 1.5 × 1.5 × 1.5 m3 at a distance of about 1 km. An additional and unique feature of this detector is its imaging capability, which in combination with other techniques, may significantly reduce false fire alarms rate when operating in an automatic mode. Preliminary results conducted with air-filled photosensitive gaseous detectors are also presented. The main advantages of this approach include both the simplicity of manufacturing and affordability of construction materials such as plastics and glues specifically reducing detector production cost. The sensitivity of these air-filled detectors at certain conditions may be as high as those filled with Ne and EF. Long-term tests of such sealed detectors indicate a significant progress in this direction. We believe that our detectors utilized in addition to other flame and smoke sensors will exceptionally increase the capability to detect forest fire at a very early stage of development. Our future efforts will be focused on attempts to commercialize such detectors utilizing our aforementioned findings.

  18. Quantum Device Applications of Mesoscopic Superconductivity

    NASA Astrophysics Data System (ADS)

    Hakonen, P. J.

    2006-08-01

    A brief account is given on the possibilities of mesoscopic superconductivity in low-noise amplifier and detector applications. In particular, three devices will be described: 1) Bloch oscillating transistor (BOT), 2) Inductively-read superconducting Cooper pair transistor (L-SET), and 3) Quantum capacitive phase detector (C-SET). The BOT is a low-noise current amplifier while the L-SET and C-SET act as ultra-sensitive charge and phase detectors, respectively. The basic operating principles and the main characteristics of these devices will be reviewed and discussed.

  19. Transcriptomic Analysis of Grape (Vitis vinifera L.) Leaves after Exposure to Ultraviolet C Irradiation

    PubMed Central

    Xi, Huifen; Ma, Ling; Liu, Guotian; Wang, Nian; Wang, Junfang; Wang, Lina; Dai, Zhanwu; Li, Shaohua; Wang, Lijun

    2014-01-01

    Background Only a small amount of solar ultraviolet C (UV-C) radiation reaches the Earth's surface. This is because of the filtering effects of the stratospheric ozone layer. Artificial UV-C irradiation is used on leaves and fruits to stimulate different biological processes in plants. Grapes are a major fruit crop and are grown in many parts of the world. Research has shown that UV-C irradiation induces the biosynthesis of phenols in grape leaves. However, few studies have analyzed the overall changes in gene expression in grape leaves exposed to UV-C. Methodology/Principal Findings In the present study, transcriptional responses were investigated in grape (Vitis vinifera L.) leaves before and after exposure to UV-C irradiation (6 W·m−2 for 10 min) using an Affymetrix Vitis vinifera (Grape) Genome Array (15,700 transcripts). A total of 5274 differentially expressed probe sets were defined, including 3564 (67.58%) probe sets that appeared at both 6 and 12 h after exposure to UV-C irradiation but not before exposure. A total of 468 (8.87%) probe sets and 1242 (23.55%) probe sets were specifically expressed at these times. The probe sets were associated with a large number of important traits and biological pathways, including cell rescue (i.e., antioxidant enzymes), protein fate (i.e., HSPs), primary and secondary metabolism, and transcription factors. Interestingly, some of the genes involved in secondary metabolism, such as stilbene synthase, responded intensely to irradiation. Some of the MYB and WRKY family transcription factors, such as VvMYBPA1, VvMYB14, VvMYB4, WRKY57-like, and WRKY 65, were also strongly up-regulated (about 100 to 200 fold). Conclusions UV-C irridiation has an important role in some biology processes, especially cell rescue, protein fate, secondary metabolism, and regulation of transcription.These results opened up ways of exploring the molecular mechanisms underlying the effects of UV-C irradiation on grape leaves and have great implications for further studies. PMID:25464056

  20. Transcriptomic analysis of grape (Vitis vinifera L.) leaves after exposure to ultraviolet C irradiation.

    PubMed

    Xi, Huifen; Ma, Ling; Liu, Guotian; Wang, Nian; Wang, Junfang; Wang, Lina; Dai, Zhanwu; Li, Shaohua; Wang, Lijun

    2014-01-01

    Only a small amount of solar ultraviolet C (UV-C) radiation reaches the Earth's surface. This is because of the filtering effects of the stratospheric ozone layer. Artificial UV-C irradiation is used on leaves and fruits to stimulate different biological processes in plants. Grapes are a major fruit crop and are grown in many parts of the world. Research has shown that UV-C irradiation induces the biosynthesis of phenols in grape leaves. However, few studies have analyzed the overall changes in gene expression in grape leaves exposed to UV-C. In the present study, transcriptional responses were investigated in grape (Vitis vinifera L.) leaves before and after exposure to UV-C irradiation (6 W·m-2 for 10 min) using an Affymetrix Vitis vinifera (Grape) Genome Array (15,700 transcripts). A total of 5274 differentially expressed probe sets were defined, including 3564 (67.58%) probe sets that appeared at both 6 and 12 h after exposure to UV-C irradiation but not before exposure. A total of 468 (8.87%) probe sets and 1242 (23.55%) probe sets were specifically expressed at these times. The probe sets were associated with a large number of important traits and biological pathways, including cell rescue (i.e., antioxidant enzymes), protein fate (i.e., HSPs), primary and secondary metabolism, and transcription factors. Interestingly, some of the genes involved in secondary metabolism, such as stilbene synthase, responded intensely to irradiation. Some of the MYB and WRKY family transcription factors, such as VvMYBPA1, VvMYB14, VvMYB4, WRKY57-like, and WRKY 65, were also strongly up-regulated (about 100 to 200 fold). UV-C irridiation has an important role in some biology processes, especially cell rescue, protein fate, secondary metabolism, and regulation of transcription.These results opened up ways of exploring the molecular mechanisms underlying the effects of UV-C irradiation on grape leaves and have great implications for further studies.

  1. Photodiode radiation hardness, lyman-alpha emitting galaxies and photon detection in liquid argon neutrino detectors

    NASA Astrophysics Data System (ADS)

    Baptista, Brian

    2013-12-01

    My dissertation is comprised of three projects: 1) studies of Lyman-alpha Emitting galaxies (LAEs), 2) radiation hardness studies of InGaAs photodiodes (PDs), and 3) scintillation photon detection in liquid argon (LAr) neutrino detectors. I began work on the project that has now become WFIRST, developing a science case that would use WFIRST after launch for the observation of LAEs. The radiation hardness of PDs was as an effort to support the WFIRST calibration team. When WFIRST was significantly delayed, I joined an R&D effort that applied my skills to work on photon detection in LAr neutrino detectors. I report results on a broadband selection method developed to detect high equivalent width (EW) LAEs. Using photometry from the CFHT-Legacy Survey Deep 2 and 3 fields, I have spectroscopically confirmed 63 z=2.5-3.5 LAEs using the WIYN/Hydra spectrograph. Using UV continuum-fitting techniques I computed properties such as EWs, internal reddening and star formation rates. 62 of my LAEs show evidence to be normal dust-free LAEs. Second, I present an investigation into the effects of ionizing proton radiation on commercial off-the-shelf InGaAs PDs. I developed a monochromator-based test apparatus that utilized NIST-calibrated reference PDs. I tested the PDs for changes to their dark current, relative responsivity as a function of wavelength, and absolute responsivity. I irradiated the test PDs using 30, 52, and 98 MeV protons at the IU Cyclotron Facility. I found the InGaAs PDs showed increased dark current as the fluence increased with no evidence of broadband response degradation at the fluences expected at an L2 orbit and a 10-year mission lifetime. Finally, I detail my efforts on technology development of both optical detector technologies and waveshifting light guide construction for LAr vacuum UV scintillation light. Cryogenic neutrino detectors use photon detection for both accelerator based science and for SNe neutrino detection and proton decay. I have developed waveshifter doped cast acrylic light guides that convert scintillation light and guide the waveshifted light to SiPMs detectors.

  2. Rocket instrument for far-UV spectrophotometry of faint astronomical objects.

    PubMed

    Hartig, G F; Fastie, W G; Davidsen, A F

    1980-03-01

    A sensitive sounding rocket instrument for moderate (~10-A) resolution far-UV (lambda1160-lambda1750-A) spectrophotometry of faint astronomical objects has been developed. The instrument employs a photon-counting microchannel plate imaging detector and a concave grating spectrograph behind a 40-cm Dall-Kirkham telescope. A unique remote-control pointing system, incorporating an SIT vidicon aspect camera, two star trackers, and a tone-encoded command telemetry link, permits the telescope to be oriented to within 5 arc sec of any target for which suitable guide stars can be found. The design, construction, calibration, and flight performance of the instrument are discussed.

  3. Optical radiation measurements II; Proceedings of the Meeting, Orlando, FL, Mar. 27, 28, 1989

    NASA Astrophysics Data System (ADS)

    Palmer, James M.

    1989-09-01

    The present conference discusses topics in the characterization of imaging radiometers, laboratory instrumentation, field and spacecraft instrumentation, and quantum and thermal standard detectors. Attention is given to UV radiometric imaging, dual-color radiometer imagery, a novel diode-array radiometer, a novel reference spectrophotometer, radiance calibration of spherical integrators, instrumentation for measurement of spectral goniometric reflectance, and a real-time IR background discrimination radiometer. Also discussed are a multichannel radiometer for atmosphere optical property measurements, the UV spectroradiometric output of a turbojet, characterizations of the Earth Radiation Budget Experiment scanning radiometers, total-radiation thermometry, future directions in Si photodiode self-calibration, and radiometric quality Ge photodiodes.

  4. Cd1-xZnxTe photodetectors with transparent conductive ZnO contacts

    NASA Astrophysics Data System (ADS)

    Tang, Ke; Huang, Jian; Lu, Yuanxi; Hu, Yan; Shen, Yibin; Zhang, Jijun; Gu, Qingmiao; Wang, Linjun; Lu, Yicheng

    2018-03-01

    High quality Cd1-xZnxTe (CZT) films were prepared using the close-spaced sublimation (CSS) technique. CZT film UV (ultraviolet) photodetectors were fabricated with B and Ga co-doped ZnO (BGZO) transparent conductive interdigitated contacts. The contact properties of BGZO/CZT were investigated by the transmission line model (TLM). The results indicate that a good ohmic contact is formed between BGZO and CZT with a very low contact resistivity of about 0.26 Ω·cm2. Compared with CZT photodetectors with Au contacts, the detectors with BGZO contacts show a higher value of UV photo response.

  5. Spectral response of a UV flame sensor for a modern turbojet aircraft engine

    NASA Astrophysics Data System (ADS)

    Schneider, William E.; Minott, George L.

    1989-12-01

    A flame sensor is incorporated into the F404 turbojet's afterburner section in order to monitor operations. The sensor contains a gaseous-discharge-type UV detector tube. Attention is presently given to the results of a study of the relationship between the flame and the sensor at temperatures of up to 400 F, using a double monochromator-based spectroradiometric system optimized for spectral response measurements in the 200-300 nm wavelength range. Modifications have been instituted as a result of these tests which guarantee a sufficiently high sensor output signal level, irrespective of variability in afterburner flame irradiance associated with differences in engine operating conditions.

  6. Optimization of the Nano-Dust Analyzer (NDA) for operation under solar UV illumination

    NASA Astrophysics Data System (ADS)

    O`Brien, L.; Grün, E.; Sternovsky, Z.

    2015-12-01

    The performance of the Nano-Dust Analyzer (NDA) instrument is analyzed for close pointing to the Sun, finding the optimal field-of-view (FOV), arrangement of internal baffles and measurement requirements. The laboratory version of the NDA instrument was recently developed (O'Brien et al., 2014) for the detection and elemental composition analysis of nano-dust particles. These particles are generated near the Sun by the collisional breakup of interplanetary dust particles (IDP), and delivered to Earth's orbit through interaction with the magnetic field of the expanding solar wind plasma. NDA is operating on the basis of impact ionization of the particle and collecting the generated ions in a time-of-flight fashion. The challenge in the measurement is that nano-dust particles arrive from a direction close to that of the Sun and thus the instrument is exposed to intense ultraviolet (UV) radiation. The performed optical ray-tracing analysis shows that it is possible to suppress the number of UV photons scattering into NDA's ion detector to levels that allow both high signal-to-noise ratio measurements, and long-term instrument operation. Analysis results show that by avoiding direct illumination of the target, the photon flux reaching the detector is reduced by a factor of about 103. Furthermore, by avoiding the target and also implementing a low-reflective coating, as well as an optimized instrument geometry consisting of an internal baffle system and a conical detector housing, the photon flux can be reduced by a factor of 106, bringing it well below the operation requirement. The instrument's FOV is optimized for the detection of nano-dust particles, while excluding the Sun. With the Sun in the FOV, the instrument can operate with reduced sensitivity and for a limited duration. The NDA instrument is suitable for future space missions to provide the unambiguous detection of nano-dust particles, to understand the conditions in the inner heliosphere and its temporal variability, and to constrain the chemical differentiation and processing of IDPs.

  7. Temperature dependence of commercial 4H-SiC UV Schottky photodiodes for X-ray detection and spectroscopy

    NASA Astrophysics Data System (ADS)

    Zhao, S.; Lioliou, G.; Barnett, A. M.

    2017-07-01

    Two commercial-off-the-shelf (COTS) 4H-SiC UV photodiodes have been investigated for their suitability as low-cost high temperature tolerant X-ray detectors. Electrical characterisation of the photodiodes which had different active areas (0.06 mm2 and 0.5 mm2) is reported over the temperature range 0 °C to 140 °C together with measurements of the X-ray photocurrents generated when the detectors were illuminated with an 55Fe radioisotope X-ray source. The 0.06 mm2 photodiode was also investigated as a photon counting spectroscopic X-ray detector across the temperature range 0 °C to 100 °C. The depletion widths (at 120 V reverse bias) of the two diodes were found to be 2.3 μm and 4.5 μm, for the 0.06 mm2 and 0.5 mm2 detectors respectively, at 140 °C. Both devices had low leakage currents (<10 pA) at temperatures ≤40 °C even at high electric field strengths (500 kV/cm for 0.06 mm2 diode; 267 kV/cm for 0.5 mm2 diode). At 140 °C and similar field strengths (514 kV/cm for 0.06 mm2 diode; 269 kV/cm for 0.5 mm2 diode), the leakage currents of both diodes were <2 nA (corresponding to leakage current densities of 2.4 μA/cm2 and 0.3 μA/cm2 for each diode respectively). The results demonstrated that both devices could function as current mode detectors of soft X-rays at the temperatures <80 °C and that when coupled to a low noise charge sensitive preamplifier, the smaller diode functioned as a photon counting spectroscopic X-ray detector at temperatures ≤100 °C with modest energy resolution (1.6 keV FWHM at 5.9 keV at 0 °C; 2.6 keV FWHM at 5.9 keV at 100 °C). Due to their temperature tolerance, wide commercial availability, and the radiation hardness of SiC, such detectors are expected to find utility in future low-cost nanosatellite (cubesat) missions and cost-sensitive industrial applications.

  8. Transition-edge sensor imaging arrays for astrophysics applications

    NASA Astrophysics Data System (ADS)

    Burney, Jennifer Anne

    Many interesting objects in our universe currently elude observation in the optical band: they are too faint or they vary rapidly and thus any structure in their radiation is lost over the period of an exposure. Conventional photon detectors cannot simultaneously provide energy resolution and time-stamping of individual photons at fast rates. Superconducting detectors have recently made the possibility of simultaneous photon counting, imaging, and energy resolution a reality. Our research group has pioneered the use of one such detector, the Transition-Edge Sensor (TES). TES physics is simple and elegant. A thin superconducting film, biased at its critical temperature, can act as a particle detector: an incident particle deposits energy and drives the film into its superconducting-normal transition. By inductively coupling the detector to a SQUID amplifier circuit, this resistance change can be read out as a current pulse, and its energy deduced by integrating over the pulse. TESs can be used to accurately time-stamp (to 0.1 [mu]s) and energy-resolve (0.15 eV at 1.6 eV) near-IR/visible/near-UV photons at rates of 30~kHz. The first astronomical observations using fiber-coupled detectors were made at the Stanford Student Observatory 0.6~m telescope in 1999. Further observations of the Crab Pulsar from the 107" telescope at the University of Texas McDonald Observatory showed rapid phase variations over the near-IR/visible/near-UV band. These preliminary observations provided a glimpse into a new realm of observations of pulsars, binary systems, and accreting black holes promised by TES arrays. This thesis describes the development, characterization, and preliminary use of the first camera system based on Transition-Edge Sensors. While single-device operation is relatively well-understood, the operation of a full imaging array poses significant challenges. This thesis addresses all aspects related to the creation and characterization of this cryogenic imaging instrument. I discuss experiments probing a host of cryostat constraints and design innovations to surmount them; simulations and experiments to characterize and filter infrared radiation; theoretical and experimental exploration of detector and array noise, cross-talk, and position-dependence; challenges of low-temperature a nd readout electronics; acquisition and analysis of data; and first light.

  9. Performance of Gas Scintillation Proportional Counter Array for High-Energy X-Ray Observatory

    NASA Technical Reports Server (NTRS)

    Gubarev, Mikhail; Ramsey, Brian; Apple, Jeffery

    2004-01-01

    A focal plane array of high-pressure gas scintillation proportional counters (GSPC) for a High Energy X-Ray Observatory (HERO) is developed at the Marshall Space Flight Center. The array is consisted from eight GSPCs and is a part of balloon born payload scheduled to flight in May 2004. These detectors have an active area of approximately 20 square centimeters, and are filled with a high pressure (10(exp 6) Pa) xenon-helium mixture. Imaging is via crossed-grid position-sensitive phototubes sensitive in the UV region. The performance of the GSPC is well matched to that of the telescopes x-ray optics which have response to 75 keV and a focal spot size of approximately 500 microns. The detector's energy resolution, 4% FWHM at 60 keV, is adequate for resolving the broad spectral lines of astrophysical importance and for accurate continuum measurements. Results of the on-earth detector calibration will be presented and in-flight detector performance will be provided, as available.

  10. The ALICE-HMPID Detector Control System: Its evolution towards an expert and adaptive system

    NASA Astrophysics Data System (ADS)

    De Cataldo, G.; Franco, A.; Pastore, C.; Sgura, I.; Volpe, G.

    2011-05-01

    The High Momentum Particle IDentification (HMPID) detector is a proximity focusing Ring Imaging Cherenkov (RICH) for charged hadron identification. The HMPID is based on liquid C 6F 14 as the radiator medium and on a 10 m 2 CsI coated, pad segmented photocathode of MWPCs for UV Cherenkov photon detection. To ensure full remote control, the HMPID is equipped with a detector control system (DCS) responding to industrial standards for robustness and reliability. It has been implemented using PVSS as Slow Control And Data Acquisition (SCADA) environment, Programmable Logic Controller as control devices and Finite State Machines for modular and automatic command execution. In the perspective of reducing human presence at the experiment site, this paper focuses on DCS evolution towards an expert and adaptive control system, providing, respectively, automatic error recovery and stable detector performance. HAL9000, the first prototype of the HMPID expert system, is then presented. Finally an analysis of the possible application of the adaptive features is provided.

  11. First observations of speed of light tracks by a fluorescence detector looking down on the atmosphere

    NASA Astrophysics Data System (ADS)

    Abdellaoui, G.; Abe, S.; Adams, J. H., Jr.; Ahriche, A.; Allard, D.; Allen, L.; Alonso, G.; Anchordoqui, L.; Anzalone, A.; Arai, Y.; Asano, K.; Attallah, R.; Attoui, H.; Ave Pernas, M.; Bacholle, S.; Bakiri, M.; Baragatti, P.; Barrillon, P.; Bartocci, S.; Bayer, J.; Beldjilali, B.; Belenguer, T.; Belkhalfa, N.; Bellotti, R.; Belov, A.; Belov, K.; Benmessai, K.; Bertaina, M.; Biermann, P. L.; Biktemerova, S.; Bisconti, F.; Blanc, N.; Błȩcki, J.; Blin-Bondil, S.; Bobik, P.; Bogomilov, M.; Bozzo, E.; Bruno, A.; Caballero, K. S.; Cafagna, F.; Campana, D.; Capdevielle, J.-N.; Capel, F.; Caramete, A.; Caramete, L.; Carlson, P.; Caruso, R.; Casolino, M.; Cassardo, C.; Castellina, A.; Catalano, C.; Catalano, O.; Cellino, A.; Chikawa, M.; Chiritoi, G.; Christl, M. J.; Connaughton, V.; Conti, L.; Cordero, G.; Cotto, G.; Crawford, H. J.; Cremonini, R.; Csorna, S.; Cummings, A.; Dagoret-Campagne, S.; De Donato, C.; de la Taille, C.; De Santis, C.; del Peral, L.; Di Martino, M.; Diaz Damian, A.; Djemil, T.; Dutan, I.; Ebersoldt, A.; Ebisuzaki, T.; Engel, R.; Eser, J.; Fenu, F.; Fernández-González, S.; Fernández-Soriano, J.; Ferrarese, S.; Flamini, M.; Fornaro, C.; Fouka, M.; Franceschi, A.; Franchini, S.; Fuglesang, C.; Fujii, T.; Fujimoto, J.; Fukushima, M.; Galeotti, P.; García-Ortega, E.; Garipov, G.; Gascón, E.; Genci, J.; Giraudo, G.; González Alvarado, C.; Gorodetzky, P.; Greg, R.; Guarino, F.; Guzmán, A.; Hachisu, Y.; Haiduc, M.; Harlov, B.; Haungs, A.; Hernández Carretero, J.; Hidber Cruz, W.; Ikeda, D.; Inoue, N.; Inoue, S.; Isgrò, F.; Itow, Y.; Jammer, T.; Jeong, S.; Joven, E.; Judd, E. G.; Jung, A.; Jochum, J.; Kajino, F.; Kajino, T.; Kalli, S.; Kaneko, I.; Karadzhov, Y.; Karczmarczyk, J.; Katahira, K.; Kawai, K.; Kawasaki, Y.; Kedadra, A.; Khales, H.; Khrenov, B. A.; Kim, Jeong-Sook; Kim, Soon-Wook; Kleifges, M.; Klimov, P. A.; Kolev, D.; Krantz, H.; Kreykenbohm, I.; Kudela, K.; Kurihara, Y.; Kusenko, A.; Kuznetsov, E.; La Barbera, A.; Lachaud, C.; Lahmar, H.; Lakhdari, F.; Larson, R.; Larsson, O.; Lee, J.; Licandro, J.; López Campano, L.; Maccarone, M. C.; Mackovjak, S.; Mahdi, M.; Maravilla, D.; Marcelli, L.; Marcos, J. L.; Marini, A.; Marszał, W.; Martens, K.; Martín, Y.; Martinez, O.; Martucci, M.; Masciantonio, G.; Mase, K.; Mastafa, M.; Matev, R.; Matthews, J. N.; Mebarki, N.; Medina-Tanco, G.; Mendoza, M. A.; Menshikov, A.; Merino, A.; Meseguer, J.; Meyer, S. S.; Mimouni, J.; Miyamoto, H.; Mizumoto, Y.; Monaco, A.; Morales de los Ríos, J. A.; Moretto, C.; Nagataki, S.; Naitamor, S.; Napolitano, T.; Naslund, W.; Nava, R.; Neronov, A.; Nomoto, K.; Nonaka, T.; Ogawa, T.; Ogio, S.; Ohmori, H.; Olinto, A. V.; Orleański, P.; Osteria, G.; Pagliaro, A.; Painter, W.; Panasyuk, M. I.; Panico, B.; Pasqualino, G.; Parizot, E.; Park, I. H.; Pastircak, B.; Patzak, T.; Paul, T.; Pérez-Grande, I.; Perfetto, F.; Peter, T.; Picozza, P.; Pindado, S.; Piotrowski, L. W.; Piraino, S.; Placidi, L.; Plebaniak, Z.; Pliego, S.; Pollini, A.; Polonski, Z.; Popescu, E. M.; Prat, P.; Prévôt, G.; Prieto, H.; Puehlhofer, G.; Putis, M.; Rabanal, J.; Radu, A. A.; Reyes, M.; Rezazadeh, M.; Ricci, M.; Rodríguez Frías, M. D.; Rodencal, M.; Ronga, F.; Roudil, G.; Rusinov, I.; Rybczyński, M.; Sabau, M. D.; Sáez Cano, G.; Sagawa, H.; Sahnoune, Z.; Saito, A.; Sakaki, N.; Salazar, H.; Sanchez Balanzar, J. C.; Sánchez, J. L.; Santangelo, A.; Sanz-Andrés, A.; Sanz Palomino, M.; Saprykin, O.; Sarazin, F.; Sato, M.; Schanz, T.; Schieler, H.; Scotti, V.; Selmane, S.; Semikoz, D.; Serra, M.; Sharakin, S.; Shimizu, H. M.; Shinozaki, K.; Shirahama, T.; Spataro, B.; Stan, I.; Sugiyama, T.; Supanitsky, D.; Suzuki, M.; Szabelska, B.; Szabelski, J.; Tajima, N.; Tajima, T.; Takahashi, Y.; Takami, H.; Takeda, M.; Takizawa, Y.; Talai, M. C.; Tenzer, C.; Thomas, S. B.; Tibolla, O.; Tkachev, L.; Tokuno, H.; Tomida, T.; Tone, N.; Toscano, S.; Traïche, M.; Tsenov, R.; Tsunesada, Y.; Tsuno, K.; Tubbs, J.; Turriziani, S.; Uchihori, Y.; Vaduvescu, O.; Valdés-Galicia, J. F.; Vallania, P.; Vankova, G.; Vigorito, C.; Villaseñor, L.; Vlcek, B.; von Ballmoos, P.; Vrabel, M.; Wada, S.; Watanabe, J.; Watts, J., Jr.; Weber, M.; Weigand Muñoz, R.; Weindl, A.; Wiencke, L.; Wille, M.; Wilms, J.; Włodarczyk, Z.; Yamamoto, T.; Yang, J.; Yano, H.; Yashin, I. V.; Yonetoku, D.; Yoshida, S.; Young, R.; Zgura, I. S.; Zotov, M. Yu.; Zuccaro Marchi, A.

    2018-05-01

    EUSO-Balloon is a pathfinder mission for the Extreme Universe Space Observatory onboard the Japanese Experiment Module (JEM-EUSO). It was launched on the moonless night of the 25th of August 2014 from Timmins, Canada. The flight ended successfully after maintaining the target altitude of 38 km for five hours. One part of the mission was a 2.5 hour underflight using a helicopter equipped with three UV light sources (LED, xenon flasher and laser) to perform an inflight calibration and examine the detectors capability to measure tracks moving at the speed of light. We describe the helicopter laser system and details of the underflight as well as how the laser tracks were recorded and found in the data. These are the first recorded laser tracks measured from a fluorescence detector looking down on the atmosphere. Finally, we present a first reconstruction of the direction of the laser tracks relative to the detector.

  12. Maximizing the quantum efficiency of microchannel plate detectors - The collection of photoelectrons from the interchannel web using an electric field

    NASA Technical Reports Server (NTRS)

    Taylor, R. C.; Hettrick, M. C.; Malina, R. F.

    1983-01-01

    High quantum efficiency and two-dimensional imaging capabilities make the microchannel plate (MCP) a suitable detector for a sky survey instrument. The Extreme Ultraviolet Explorer satellite, to be launched in 1987, will use MCP detectors. A feature which limits MCP efficiency is related to the walls of individual channels. The walls are of finite thickness and thus form an interchannel web. Under normal circumstances, this web does not contribute to the detector's quantum efficiency. Panitz and Foesch (1976) have found that in the case of a bombardment with ions, electrons were ejected from the electrode material coating the web. By applying a small electric field, the electrons were returned to the MCP surface where they were detected. The present investigation is concerned with the enhancement of quantum efficiencies in the case of extreme UV wavelengths. Attention is given to a model and a computer simulation which quantitatively reproduce the experimental results.

  13. Design, fabrication and characterization of an a-Si:H-based UV detector for sunburn applications

    NASA Astrophysics Data System (ADS)

    Bayat, Khadijeh; Vygranenko, Yuriy; Sazonov, Andrei; Farrokh-Baroughi, Mahdi

    2006-12-01

    A thin-film a-Si:H pin detector was developed for selective detection of UVA (320-400 nm) radiation. In order for the fabrication technology to be transferable onto flexible substrates, all of the processing steps were conducted at temperatures less than 125 °C. The measured saturation current as low as 2 pA cm-2 and the ideality factor of 1.47 show that the pin diodes have a good quality i-layer as well as p-i and n-i interfaces. The film thicknesses were optimized to suppress the detector sensitivity in the visible spectral range, and the peak of spectral response was observed at 410 nm. The selectivity estimated from the ratio of the photocurrent generated by UVA absorption to the total photocurrent is 21%.

  14. Characterisation of dissolved organic matter in stormwater using high-performance size exclusion chromatography.

    PubMed

    Huang, Huiping; Chow, Christopher W K; Jin, Bo

    2016-04-01

    Understanding the complexity of dissolved organic matter (DOM) in stormwater has drawn a lot of interest, since DOM from stormwater causes not only environmental impacts, but also worsens downstream aquatic quality associated with water supply and treatability. This study introduced and employed high-performance size exclusion chromatography (HPSEC) coupled with an ultraviolet-visible (UV-vis) diode array detector to assess changes in stormwater-associated DOM characteristics. Stormwater DOM was also analysed in relation to storm event characteristics, water quality and spectroscopic analysis. Statistical tools were used to determine the correlations within DOM and water quality measurements. Results showed that dissolved organic carbon (DOC) and UV absorbance at 254 nm (UV254) as conventional DOM parameters were found to be correlated well to the changes in stormwater quality during each of the three storm events studied. Both detector wavelengths (210 and 254 nm) and their ratio (A210/A254) were found to provide additional information on the physiochemical properties of stormwater-associated DOM. This study indicated that A210/A254 is an important parameter which could be used to estimate the DOM proportions of functional groups and conjugated carbon species. This study provided also an understanding of stormwater quality constituents through assessing variability and sensitivity for various parameters, and the additional information of rainfall characteristics on runoff quality data for a better understanding of parameter correlations and influences. Copyright © 2015. Published by Elsevier B.V.

  15. A method for optimizing the cosine response of solar UV diffusers

    NASA Astrophysics Data System (ADS)

    Pulli, Tomi; Kärhä, Petri; Ikonen, Erkki

    2013-07-01

    Instruments measuring global solar ultraviolet (UV) irradiance at the surface of the Earth need to collect radiation from the entire hemisphere. Entrance optics with angular response as close as possible to the ideal cosine response are necessary to perform these measurements accurately. Typically, the cosine response is obtained using a transmitting diffuser. We have developed an efficient method based on a Monte Carlo algorithm to simulate radiation transport in the solar UV diffuser assembly. The algorithm takes into account propagation, absorption, and scattering of the radiation inside the diffuser material. The effects of the inner sidewalls of the diffuser housing, the shadow ring, and the protective weather dome are also accounted for. The software implementation of the algorithm is highly optimized: a simulation of 109 photons takes approximately 10 to 15 min to complete on a typical high-end PC. The results of the simulations agree well with the measured angular responses, indicating that the algorithm can be used to guide the diffuser design process. Cost savings can be obtained when simulations are carried out before diffuser fabrication as compared to a purely trial-and-error-based diffuser optimization. The algorithm was used to optimize two types of detectors, one with a planar diffuser and the other with a spherically shaped diffuser. The integrated cosine errors—which indicate the relative measurement error caused by the nonideal angular response under isotropic sky radiance—of these two detectors were calculated to be f2=1.4% and 0.66%, respectively.

  16. Charge management for gravitational-wave observatories using UV LEDs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pollack, S. E.; Turner, M. D.; Schlamminger, S.

    Accumulation of electrical charge on the end mirrors of gravitational-wave observatories can become a source of noise limiting the sensitivity of such detectors through electronic couplings to nearby surfaces. Torsion balances provide an ideal means for testing gravitational-wave technologies due to their high sensitivity to small forces. Our torsion pendulum apparatus consists of a movable plate brought near a plate pendulum suspended from a nonconducting quartz fiber. A UV LED located near the pendulum photoejects electrons from the surface, and a UV LED driven electron gun directs photoelectrons towards the pendulum surface. We have demonstrated both charging and discharging ofmore » the pendulum with equivalent charging rates of {approx}10{sup 5}e/s, as well as spectral measurements of the pendulum charge resulting in a white noise level equivalent to 3x10{sup 5}e/{radical}(Hz).« less

  17. Robust and economical multi-sample, multi-wavelength UV/vis absorption and fluorescence detector for biological and chemical contamination

    NASA Astrophysics Data System (ADS)

    Lu, Peter J.; Hoehl, Melanie M.; Macarthur, James B.; Sims, Peter A.; Ma, Hongshen; Slocum, Alexander H.

    2012-09-01

    We present a portable multi-channel, multi-sample UV/vis absorption and fluorescence detection device, which has no moving parts, can operate wirelessly and on batteries, interfaces with smart mobile phones or tablets, and has the sensitivity of commercial instruments costing an order of magnitude more. We use UV absorption to measure the concentration of ethylene glycol in water solutions at all levels above those deemed unsafe by the United States Food and Drug Administration; in addition we use fluorescence to measure the concentration of d-glucose. Both wavelengths can be used concurrently to increase measurement robustness and increase detection sensitivity. Our small robust economical device can be deployed in the absence of laboratory infrastructure, and therefore may find applications immediately following natural disasters, and in more general deployment for much broader-based testing of food, agricultural and household products to prevent outbreaks of poisoning and disease.

  18. WFC3 UVIS Pixel-to-Pixel QE Variations via Internal Flats Monitor

    NASA Astrophysics Data System (ADS)

    Mckay, Myles

    2017-08-01

    The UVIS detector has a population of pixels that exhibit anomalous QE variations between anneals, characterized by a sensitivity loss that is greater in the shorter wavelengths(blue) than in the longer wavelengths(red). This population is distributed randomly, with evidence of grouping behavior in the UV, and is seemingly different for each anneal cycle. This program, a continuation of cycle 24 program 14546, will aim to constrain the maximum low-sensitivity population existing before an anneal in both the UV and Visible filters. To monitor the UV behavior, internal flats with the Deuterium D2 lamp will be taken through the filters, F225W and F336W. To monitor the behavior in the Visible filters, internal flats with the tungsten lamp will be taken through F814W and F438W a week before the anneal, when the population of anomalous pixels is the greatest.

  19. Fast and slow UV-photoresponse in n-type GaN

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rocha, R.; Koynov, S.; Brogueira, P.

    1999-07-01

    The photocurrent decay in n-type GaN films prepared by low-pressure chemical vapor deposition (LPCVD) was measured in the ms-to-s time range using steady-state UV light and in the {micro}s time regime using short high-power pulses from higher harmonics of a Nd:YAG laser. A power law time dependence is observed with exponents ranging from {minus}0.1 to {minus}0.3, which is an indication of a broad distribution of trapping states inside the band gap. Combining Hall effect results and the magnitude of the initial slope of the photocurrent decay they estimate a mobility-lifetime product of 2.1 x 10{sup {minus}4} cm{sup 2}/V for photogeneratedmore » electrons at times below a few {micro}s. Slow transients might be a handicap for applications of GaN in UV detectors.« less

  20. Application of ZnO Nanoparticle as Sulphide Gas Sensor Using UV/VIS/NIR-Spectrophotometer

    NASA Astrophysics Data System (ADS)

    Juliasih, N.; Buchari; Noviandri, I.

    2017-04-01

    The nanoparticle of metal oxides has great unique characteristics that applicable to the wide industrial as sensors and catalysts for reducing environmental pollution. Sulphide gas monitors and detectors are required for assessing safety aspects, due to its toxicity level. A thin film of ZnO as the sulphide gas sensor was synthesised by the simple method of chemical liquid deposition with variation of annealing temperature from 200 ºC to 500 ºC, and characterised by Scanning Electron Microscope (SEM), X-Ray Diffraction (XRD), and UV/VIS/NIR-Spectrophotometer. Characterization studies showed nanoparticle size from the range 62 - 92 nm of diameters. The application this ZnO thin film to sulfide gas, detected by UV/VIS/NIR Spectrophotometer with diffuse reflectance, showed specific chemical reaction by the shifting of maximum % Reflectance peak. The gas sensing using this method is applicable at room.

  1. Absolute measurement of the extreme UV solar flux

    NASA Technical Reports Server (NTRS)

    Carlson, R. W.; Ogawa, H. S.; Judge, D. L.; Phillips, E.

    1984-01-01

    A windowless rare-gas ionization chamber has been developed to measure the absolute value of the solar extreme UV flux in the 50-575-A region. Successful results were obtained on a solar-pointing sounding rocket. The ionization chamber, operated in total absorption, is an inherently stable absolute detector of ionizing UV radiation and was designed to be independent of effects from secondary ionization and gas effusion. The net error of the measurement is + or - 7.3 percent, which is primarily due to residual outgassing in the instrument, other errors such as multiple ionization, photoelectron collection, and extrapolation to the zero atmospheric optical depth being small in comparison. For the day of the flight, Aug. 10, 1982, the solar irradiance (50-575 A), normalized to unit solar distance, was found to be 5.71 + or - 0.42 x 10 to the 10th photons per sq cm sec.

  2. Atomic Data for Stellar Astrophysics: from the UV to the IR

    NASA Technical Reports Server (NTRS)

    Wahlgren, Glenn M.

    2011-01-01

    The study of stars and stellar evolution relies heavily on the analysis of stellar spectra. The need for atomic line data from the ultraviolet (UV) to the infrared (lR) regions is greater now than ever. In the past twenty years, the time since the launch of the Hubble Space Telescope, great progress has been made in acquiring atomic data for UV transitions. The optical wavelength region, now expanded by progress in detector technology, continues to provide motivation for new atomic data. In addition, investments in new instrumentation for ground-based and space observatories has lead to the availability of high-quality spectra at IR wavelengths, where the need for atomic data is most critical. In this review, examples are provided of the progress made in generating atomic data for stellar studies, with a look to the future for addressing the accuracy and completeness of atomic data for anticipated needs.

  3. Determination of aesculin in rat plasma by high performance liquid chromatography method and its application to pharmacokinetics studies.

    PubMed

    Chen, QiuHong; Hou, ShiXiang; Zheng, Jia; Bi, YueQi; Li, YuanBo; Yang, XiaoJiao; Cai, Zheng; Song, XiangRong

    2007-10-15

    A sensitive and reproducible high performance liquid chromatography method with UV detection was described for the determination of aesculin in rat plasma. After deproteinization by methanol using metronidazole as internal standard (I.S.), solutes were evaporated to dryness at 40 degrees C under a gentle stream of nitrogen. The residue was reconstituted in 100 microl of mobile phase and a volume of 20 microl was injected into the HPLC for analysis. Solutes were separated on a Diamonsil C18 column (250 mm x 4.6 mm i.d., 5 microm particle size, Dikma) protected by a ODS guard column (10 mm x 4.0 mm i.d., 5 microm particle size), using acetonitrile-0.1% triethylamine solution (adjusted to pH 3.0 using phosphoric acid) (10:90, v/v) as mobile phase (flow-rate 1.0 ml/min), and wavelength of the UV detector was set at 338 nm. No interference from any endogenous substances was observed during the elution of aesculin and internal standard (I.S., metronidazole). The retention times for I.S and aesculin were 10.4 and 12.4 min, respectively. The limit of quantification was evaluated to be 57.4 ng/ml and the limit of detection was 24.0 ng/ml. The method was used in the study of pharmacokinetics of aesculin after intraperitoneal injection (i.p.) administration in rats.

  4. Development of a gradient HPLC method for the simultaneous determination of sotalol and sorbate in oral liquid preparations using solid core stationary phase.

    PubMed

    Matysova, Ludmila; Zahalkova, Oxana; Klovrzova, Sylva; Sklubalova, Zdenka; Solich, Petr; Zahalka, Lukas

    2015-01-01

    A selective and sensitive gradient HPLC-UV method for quantification of sotalol hydrochloride and potassium sorbate in five types of oral liquid preparations was developed and fully validated. The separation of an active substance sotalol hydrochloride, potassium sorbate (antimicrobial agent), and other substances (for taste and smell correction, etc.) was performed using an Ascentis Express C18 (100 × 4.6 mm, particles 2.7 μm) solid core HPLC column. Linear gradient elution mode with a flow rate of 1.3 mL min(-1) was used, and the injection volume was 5 µL. The UV/Vis absorbance detector was set to a wavelength of 237 nm, and the column oven was conditioned at 25°C. A sodium dihydrogen phosphate dihydrate solution (pH 2.5; 17.7 mM) was used as the mobile phase buffer. The total analysis time was 4.5 min (+2.5 min for reequilibration). The method was successfully employed in a stability evaluation of the developed formulations, which are now already being used in the therapy of arrhythmias in pediatric patients; the method is also suitable for general quality control, that is, not only just for extemporaneous preparations containing the mentioned substances.

  5. Development of a Gradient HPLC Method for the Simultaneous Determination of Sotalol and Sorbate in Oral Liquid Preparations Using Solid Core Stationary Phase

    PubMed Central

    2015-01-01

    A selective and sensitive gradient HPLC-UV method for quantification of sotalol hydrochloride and potassium sorbate in five types of oral liquid preparations was developed and fully validated. The separation of an active substance sotalol hydrochloride, potassium sorbate (antimicrobial agent), and other substances (for taste and smell correction, etc.) was performed using an Ascentis Express C18 (100 × 4.6 mm, particles 2.7 μm) solid core HPLC column. Linear gradient elution mode with a flow rate of 1.3 mL min−1 was used, and the injection volume was 5 µL. The UV/Vis absorbance detector was set to a wavelength of 237 nm, and the column oven was conditioned at 25°C. A sodium dihydrogen phosphate dihydrate solution (pH 2.5; 17.7 mM) was used as the mobile phase buffer. The total analysis time was 4.5 min (+2.5 min for reequilibration). The method was successfully employed in a stability evaluation of the developed formulations, which are now already being used in the therapy of arrhythmias in pediatric patients; the method is also suitable for general quality control, that is, not only just for extemporaneous preparations containing the mentioned substances. PMID:25878920

  6. VizieR Online Data Catalog: UBV(RI)c photometry of Stock 16 (Vazquez+, 2005)

    NASA Astrophysics Data System (ADS)

    Vazquez, R. A.; Baume, G. L.; Feinstein, C.; Nunez, J. A.; Vergne, M. M.

    2005-02-01

    CCD UBV(RI)c imaging photometry was carried out in the field of Stock 16 along two observational runs at the University of Toronto Southern Observatory, Las Campanas, Chile, using the Hellen Sawyer Hogg 60-cm telescope: on the nights of 1994 April 13, 14 and 16, we obtained UBVRI photometry for four frames with the nitrogen-cooled detector PM METHACROME UV coated (0.45"/pix) covering 4' on a side; three more frames were exposed on the nights of 1996 February 25 and 26 in the UBV(I)c bands (this time, the detector was glycol-refrigerated). (1 data file).

  7. Enhanced photoelectric performance in self-powered UV detectors based on ZnO nanowires with plasmonic Au nanoparticles scattered electrolyte

    NASA Astrophysics Data System (ADS)

    Zeng, Yiyu; Ye, Zhizhen; Lu, Bin; Dai, Wei; Pan, Xinhua

    2016-04-01

    Vertically aligned ZnO nanowires (NWs) were grown on a fluorine-doped tin-oxide-coated glass substrate by a hydrothermal method. Au nanoparticles were well dispersed in the mixed solution of ethanol and deionized water. A simple self-powered ultraviolet detector based on solid-liquid heterojunction was fabricated, utilizing ZnO NWs as active photoanode and such prepared mixed solution as electrolyte. The introduction of Au nanoparticles results in considerable improvements in the responsivity and sensitivity of the device compared with the one using deionized water as electrolyte, which is attributed to the enhanced light harvesting by Au nanoparticles.

  8. Ultraviolet corona detection sensor study

    NASA Technical Reports Server (NTRS)

    Schmitt, R. J.; MATHERN

    1976-01-01

    The feasibility of detecting electrical corona discharge phenomena in a space simulation chamber via emission of ultraviolet light was evaluated. A corona simulator, with a hemispherically capped point to plane electrode geometry, was used to generate corona glows over a wide range of pressure, voltage, current, electrode gap length and electrode point radius. Several ultraviolet detectors, including a copper cathode gas discharge tube and a UV enhanced silicon photodiode detector, were evaluated in the course of the spectral intensity measurements. The performance of both silicon target vidicons and silicon intensified target vidicons was evaluated analytically using the data generated by the spectroradiometer scans and the performance data supplied by the manufacturers.

  9. A multi-wavelength (u.v. to visible) laser system for early detection of oral cancer

    NASA Astrophysics Data System (ADS)

    Najda, S. P.; Perlin, P.; Leszczyński, M.; Slight, T. J.; Meredith, W.; Schemmann, M.; Moseley, H.; Woods, J. A.; Valentine, R.; Kalra, S.; Mossey, P.; Theaker, E.; Macluskey, M.; Mimnagh, G.; Mimnagh, W.

    2015-03-01

    A multi-wavelength (360nm - 440nm), real-time Photonic Cancer Detector (PCD) optical system based on GaN semiconductor laser technology is outlined. A proof of concept using blue laser technology for early detection of cancer has already been tested and proven for esophageal cancer. This concept is expanded to consider a wider range of wavelengths and the PCD will initially be used for early diagnosis of oral cancers. The PCD creates an image of the oral cavity (broad field white light detection) and maps within the oral cavity any suspicious lesions with high sensitivity using a narrow field tunable detector.

  10. Cloud and aerosol polarimetric imager

    NASA Astrophysics Data System (ADS)

    Zhang, Junqiang; Shao, Jianbing; Yan, Changxiang

    2014-02-01

    Cloud and Aerosol Polarimetric Imager (CAPI), which is the first onboard cloud and aerosol Polarimetric detector of CHINA, is developed to get cloud and aerosol data of atmosphere to retrieve aerosol optical and microphysical properties to increase the reversion precision of greenhouse gasses (GHGs). The instrument is neither a Polarization and Direction of Earth's Reflectance (POLDER) nor a Directional Polarimetric Camera (DPC) type polarized camera. It is a multispectral push broom system using linear detectors, and can get 5 bands spectral data, from ultraviolet (UV) to SWIR, of the same ground feature at the same time without any moving structure. This paper describes the CAPI instrument characteristics, composition, calibration, and the nearest development.

  11. UV-IR Hydrogen Fire Detector

    NASA Technical Reports Server (NTRS)

    Medelius, Pedro J.; Steinrock, T. (Technical Monitor)

    2001-01-01

    The objective of this project is to design a sensor than can accurately determine the presence of a hydrogen fire within its field of view and to eliminate the main cause of false alarms: reflections from the flare stack. Details are given in viewgraph presentation form on the technical approach, initial testing, sensor testing, intellectual property, patented technology, and licensing.

  12. Sensitive determination of nitrophenol isomers by reverse-phase high-performance liquid chromatography in conjunction with liquid-liquid extraction

    USDA-ARS?s Scientific Manuscript database

    A method for the highly sensitive determination of 2-, 3- and 4- nitrophenols was developed using reverse-phase high-performance liquid chromatography (RP-HPLC) with a UV photodiode array detector. Using a reverse-phase column and 40% aqueous acetonitrile as an eluent (i.e. isocratic elution), the i...

  13. Diesel Engine Air Emissions Reduction Technologies

    DTIC Science & Technology

    2010-04-01

    Hour GC/MS Gas Chromatography /Mass Spectroscopy GC/FID Gas Chromatography /Flame Ionization Detector g/mile Gram per Mile HAP Hazardous Air...Pollutant HC Hydrocarbon HPLC/UV High Performance Liquid Chromatography / Ultraviolet KPa Kilo-Pascals NDIR Non Dispersive Infrared... Chromatography (GC) where the samples were collected on DNPH cartridges. Portable versions of these instruments were available and employed for

  14. 'Dilute-and-shoot' triple parallel mass spectrometry method for analysis of vitamin D and triacylglycerols in dietary supplements

    USDA-ARS?s Scientific Manuscript database

    A method is demonstrated for analysis of vitamin D-fortified dietary supplements that eliminates virtually all chemical pretreatment prior to analysis, and is referred to as a ‘dilute and shoot’ method. Three mass spectrometers, in parallel, plus a UV detector, an evaporative light scattering detec...

  15. Mechanisms of Chinese Red Yeast Rice Inhibition of Prostate Cancer Growth

    DTIC Science & Technology

    2009-04-01

    cou- pled with a model 490E Programmable Multiwavelength UV detector (Waters Corp., Milford, MA) with conditions as follows: column, Phenomenex...5.93 M MK, and this led to 47% and 77% inhibition of LNCaP and 62% and 65% inhibition of LNCaP-AR cell growth in 48 and 72 hours of treatments

  16. An ultraviolet floral polymorphism associated with life history drives pollinator discrimination in Mimulus guttatus.

    PubMed

    Peterson, Megan L; Miller, Timothy J; Kay, Kathleen M

    2015-03-01

    • Ultraviolet (UV) floral patterns are common in angiosperms and mediate pollinator attraction, efficiency, and constancy. UV patterns may vary within species, yet are cryptic to human observers. Thus, few studies have explicitly described the distribution or ecological significance of intraspecific variation in UV floral patterning. Here, we describe the geographic distribution and pattern of inheritance of a UV polymorphism in the model plant species Mimulus guttatus (Phrymaceae). We then test whether naturally occurring UV phenotypes influence pollinator interactions within M. guttatus.• We document UV patterns in 18 annual and 19 perennial populations and test whether UV pattern is associated with life history. To examine the pattern of inheritance, we conducted crosses within and between UV phenotypes. Finally, we tested whether bee pollinators discriminate among naturally occurring UV phenotypes in two settings: wild bee communities and captive Bombus impatiens.• Within M. guttatus, perennial populations exhibit a small bulls-eye pattern, whereas a bilaterally symmetric runway pattern occurs mainly in annual populations. Inheritance of UV patterning is consistent with a single-locus Mendelian model in which the runway phenotype is dominant. Bee pollinators discriminate against unfamiliar UV patterns in both natural and controlled settings.• We describe a widespread UV polymorphism associated with life history divergence within Mimulus guttatus. UV pattern influences pollinator visitation and should be considered when estimating reproductive barriers between life history ecotypes. This work develops a new system to investigate the ecology and evolution of UV floral patterning in a species with extensive genomic resources. © 2015 Botanical Society of America, Inc.

  17. Determination of the molecular weight of low-molecular-weight heparins by using high-pressure size exclusion chromatography on line with a triple detector array and conventional methods.

    PubMed

    Bisio, Antonella; Mantegazza, Alessandra; Vecchietti, Davide; Bensi, Donata; Coppa, Alessia; Torri, Giangiacomo; Bertini, Sabrina

    2015-03-19

    The evaluation of weight average molecular weight (Mw) and molecular weight distribution represents one of the most controversial aspects concerning the characterization of low molecular weight heparins (LMWHs). As the most commonly used method for the measurement of such parameters is high performance size exclusion chromatography (HP-SEC), the soundness of results mainly depends on the appropriate calibration of the chromatographic columns used. With the aim of meeting the requirement of proper Mw standards for LMWHs, in the present work the determination of molecular weight parameters (Mw and Mn) by HP-SEC combined with a triple detector array (TDA) was performed. The HP-SEC/TDA technique permits the evaluation of polymeric samples by exploiting the combined and simultaneous action of three on-line detectors: light scattering detectors (LALLS/RALLS); refractometer and viscometer. Three commercial LMWH samples, enoxaparin, tinzaparin and dalteparin, a γ-ray depolymerized heparin (γ-Hep) and its chromatographic fractions, and a synthetic pentasaccharide were analysed by HP-SEC/TDA. The same samples were analysed also with a conventional HP-SEC method employing refractive index (RI) and UV detectors and two different chromatographic column set, silica gel and polymeric gel columns. In both chromatographic systems, two different calibration curves were built up by using (i) γ-Hep chromatographic fractions and the corresponding Mw parameters obtained via HP-SEC/TDA; (ii) the whole γ-Hep preparation with broad Mw dispersion and the corresponding cumulative distribution function calculated via HP-SEC/TDA. In addition, also a chromatographic column calibration according to European Pharmacopoeia indication was built up. By comparing all the obtained results, some important differences among Mw and size distribution values of the three LMWHs were found with the five different calibration methods and with HP-SEC/TDA method. In particular, the detection of the lower molecular weight components turned out to be the most critical aspect. Whereas HP-SEC/TDA may underestimate species under 2 KDa when present in low concentration, other methods appeared to emphasize their content.

  18. Development and validation of liquid chromatographic and UV derivative spectrophotometric methods for the determination of famciclovir in pharmaceutical dosage forms.

    PubMed

    Srinubabu, Gedela; Sudharani, Batchu; Sridhar, Lade; Rao, Jvln Seshagiri

    2006-06-01

    A high-performance liquid chromatographic method and a UV derivative spectrophotometric method for the determination of famciclovir, a highly active antiviral agent, in tablets were developed in the present work. The various parameters, such as linearity, precision, accuracy, specificity, robustness, limit of detection and limit of quantitation were studied according to International Conference on Harmonization guidelines. HPLC was carried out by using the reversed-phase technique on an RP-18 column with a mobile phase composed of 50 mM monobasic phosphate buffer and methanol (50 : 50; v/v), adjusted to pH 3.05 with orthophosphoric acid. The mobile phase was pumped at a flow rate of 1 ml/min and detection was made at 242 nm with UV dual absorbance detector. The first derivative UV spectrophotometric method was performed at 226.5 nm. Statistical analysis was done by Student's t-test and F-test, which showed no significant difference between the results obtained by the two methods. The proposed methods are highly sensitive, precise and accurate and therefore can be used for its Intended purpose.

  19. A Comprehensive Review of Semiconductor Ultraviolet Photodetectors: From Thin Film to One-Dimensional Nanostructures

    PubMed Central

    Sang, Liwen; Liao, Meiyong; Sumiya, Masatomo

    2013-01-01

    Ultraviolet (UV) photodetectors have drawn extensive attention owing to their applications in industrial, environmental and even biological fields. Compared to UV-enhanced Si photodetectors, a new generation of wide bandgap semiconductors, such as (Al, In) GaN, diamond, and SiC, have the advantages of high responsivity, high thermal stability, robust radiation hardness and high response speed. On the other hand, one-dimensional (1D) nanostructure semiconductors with a wide bandgap, such as β-Ga2O3, GaN, ZnO, or other metal-oxide nanostructures, also show their potential for high-efficiency UV photodetection. In some cases such as flame detection, high-temperature thermally stable detectors with high performance are required. This article provides a comprehensive review on the state-of-the-art research activities in the UV photodetection field, including not only semiconductor thin films, but also 1D nanostructured materials, which are attracting more and more attention in the detection field. A special focus is given on the thermal stability of the developed devices, which is one of the key characteristics for the real applications. PMID:23945739

  20. A Future Large-Aperture UVOIR Space Observatory: Key Technologies and Capabilities

    NASA Technical Reports Server (NTRS)

    Bolcar, Matthew Ryan; Stahle, Carl M.; Balasubramaniam, Kunjithapatham; Clampin, Mark; Feinberg, Lee D.; Mosier, Gary E.; Quijada, Manuel A.; Rauscher, Bernard J.; Redding, David C.; Rioux, Norman M.; hide

    2015-01-01

    We present the key technologies and capabilities that will enable a future, large-aperture ultravioletopticalinfrared (UVOIR) space observatory. These include starlight suppression systems, vibration isolation and control systems, lightweight mirror segments, detector systems, and mirror coatings. These capabilities will provide major advances over current and near-future observatories for sensitivity, angular resolution, and starlight suppression. The goals adopted in our study for the starlight suppression system are 10-10 contrast with an inner working angle of 20 milliarcsec and broad bandpass. We estimate that a vibration and isolation control system that achieves a total system vibration isolation of 140 dB for a vibration-isolated mass of 5000 kg is required to achieve the high wavefront error stability needed for exoplanet coronagraphy. Technology challenges for lightweight mirror segments include diffraction-limited optical quality and high wavefront error stability as well as low cost, low mass, and rapid fabrication. Key challenges for the detector systems include visible-blind, high quantum efficiency UV arrays, photon counting visible and NIR arrays for coronagraphic spectroscopy and starlight wavefront sensing and control, and detectors with deep full wells with low persistence and radiation tolerance to enable transit imaging and spectroscopy at all wavelengths. Finally, mirror coatings with high reflectivity ( 90), high uniformity ( 1) and low polarization ( 1) that are scalable to large diameter mirror substrates will be essential for ensuring that both high throughput UV observations and high contrast observations can be performed by the same observatory.

  1. The Advanced Technology Large-Aperture Space Telescope (ATLAST) Technology Roadmap

    NASA Technical Reports Server (NTRS)

    Stahle, Carl; Balasubramanian, K.; Bolcar, M.; Clampin, M.; Feinberg, L.; Hartman, K.; Mosier, C.; Quijada, M.; Rauscher, B.; Redding, D.; hide

    2014-01-01

    We present the key technologies and capabilities that will enable a future, large-aperture ultravioletopticalinfrared (UVOIR) space observatory. These include starlight suppression systems, vibration isolation and control systems, lightweight mirror segments, detector systems, and mirror coatings. These capabilities will provide major advances over current and near-future observatories for sensitivity, angular resolution, and starlight suppression. The goals adopted in our study for the starlight suppression system are 10-10 contrast with an inner working angle of 40 milliarcsec and broad bandpass. We estimate that a vibration and isolation control system that achieves a total system vibration isolation of 140 dB for a vibration-isolated mass of 5000 kg is required to achieve the high wavefront error stability needed for exoplanet coronagraphy. Technology challenges for lightweight mirror segments include diffraction-limited optical quality and high wavefront error stability as well as low cost, low mass, and rapid fabrication. Key challenges for the detector systems include visible-blind, high quantum efficiency UV arrays, photon counting visible and NIR arrays for coronagraphic spectroscopy and starlight wavefront sensing and control, and detectors with deep full wells with low persistence and radiation tolerance to enable transit imaging and spectroscopy at all wavelengths. Finally, mirror coatings with high reflectivity ( 90), high uniformity ( 1) and low polarization ( 1) that are scalable to large diameter mirror substrates will be essential for ensuring that both high throughput UV observations and high contrast observations can be performed by the same observatory.

  2. Testing Bell's inequality with cosmic photons: closing the setting-independence loophole.

    PubMed

    Gallicchio, Jason; Friedman, Andrew S; Kaiser, David I

    2014-03-21

    We propose a practical scheme to use photons from causally disconnected cosmic sources to set the detectors in an experimental test of Bell's inequality. In current experiments, with settings determined by quantum random number generators, only a small amount of correlation between detector settings and local hidden variables, established less than a millisecond before each experiment, would suffice to mimic the predictions of quantum mechanics. By setting the detectors using pairs of quasars or patches of the cosmic microwave background, observed violations of Bell's inequality would require any such coordination to have existed for billions of years-an improvement of 20 orders of magnitude.

  3. Effect of heat-setting on UV protection and antibacterial properties of cotton/spandex fabric

    NASA Astrophysics Data System (ADS)

    Pervez, M. N.; Talukder, M. E.; Shafiq, F.; Hasan, K. M. F.; Taher, M. A.; Meraz, M. M.; Cai, Y.; Lin, Lina

    2018-01-01

    An unexampled approach for simultaneous heat setting process with optimized condition at C3 (140°C, 45 s) and functional finishing, i.e. UV protection and antibacterial properties of cotton/spandex fabric were studied in this research. Experimental results disclosed that, ameliorative antibacterial efficacy and perdurable UV protection of heat-treated cotton/spandex fabrics with best sample A3 among all samples was achieved and mechanical properties also improved as the temperature rose from 120 to 140°C. In addition, Ultraviolet (UV) radiation protection and antibacterial properties are becoming increasingly necessary for human health, and textiles play an important role and this report will be appurtenant to meet regular demand.

  4. Quantification of Coffea arabica and Coffea canephora var. robusta concentration in blends by means of synchronous fluorescence and UV-Vis spectroscopies.

    PubMed

    Dankowska, A; Domagała, A; Kowalewski, W

    2017-09-01

    The potential of fluorescence, UV-Vis spectroscopies as well as the low- and mid-level data fusion of both spectroscopies for the quantification of concentrations of roasted Coffea arabica and Coffea canephora var. robusta in coffee blends was investigated. Principal component analysis was used to reduce data multidimensionality. To calculate the level of undeclared addition, multiple linear regression (PCA-MLR) models were used with lowest root mean square error of calibration (RMSEC) of 3.6% and root mean square error of cross-validation (RMSECV) of 7.9%. LDA analysis was applied to fluorescence intensities and UV spectra of Coffea arabica, canephora samples, and their mixtures in order to examine classification ability. The best performance of PCA-LDA analysis was observed for data fusion of UV and fluorescence intensity measurements at wavelength interval of 60nm. LDA showed that data fusion can achieve over 96% of correct classifications (sensitivity) in the test set and 100% of correct classifications in the training set, with low-level data fusion. The corresponding results for individual spectroscopies ranged from 90% (UV-Vis spectroscopy) to 77% (synchronous fluorescence) in the test set, and from 93% to 97% in the training set. The results demonstrate that fluorescence, UV, and visible spectroscopies complement each other, giving a complementary effect for the quantification of roasted Coffea arabica and Coffea canephora var. robusta concentration in blends. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. High performance ultraviolet photodetectors based on ZnO nanoflakes/PVK heterojunction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cai, Yuhua; Xiang, Jinzhong, E-mail: jzhxiang@ynu.edu.cn; Tang, Libin, E-mail: scitang@163.com

    2016-08-15

    A high performance ultraviolet (UV) photodetector is receiving increasing attention due to its significant applications in fire warning, environmental monitoring, scientific research, astronomical observation, etc. The enhancement in performance of the UV photodetector has been impeded by lacking of a high-efficiency heterojunction in which UV photons can efficiently convert into charges. In this work, the high performance UV photodetectors have been realized by utilizing organic/inorganic heterojunctions based on a ZnO nanoflakes/poly (N-vinylcarbazole) hybrid. A transparent conducting polymer poly(3,4-ethylene-dioxythiophene):poly(styrenesulfonate)-coated quartz substrate is employed as the anode in replacement of the commonly ITO-coated glass in order to harvest shorter UV light. Themore » devices show a lower dark current density, with a high responsivity (R) of 7.27 × 10{sup 3 }A/W and a specific detectivity (D*) of 6.20 × 10{sup 13} cm Hz{sup 1/2}/W{sup −1} at 2 V bias voltage in ambient environment (1.30 mW/cm{sup 2} at λ = 365 nm), resulting in the enhancements in R and D* by 49% and one order of magnitude, respectively. The study sheds light on developing high-performance, large scale-array, flexible UV detectors using the solution processable method.« less

  6. Effects of drying temperature on tomato-based thin film as self-powered UV photodetector

    NASA Astrophysics Data System (ADS)

    Thu, Myo Myo; Mastuda, Atsunori; Cheong, Kuan Yew

    2018-07-01

    In this work, tomato thin-film is used as an active natural organic layer for UV photodetector. The effects of drying temperature (60-140 °C) on structural, chemical, electrical and UV sensing properties of tomato thin-film have been investigated. The photodetector consists of a glass substrate/tomato thin-film active layer/interdigitated aluminium electrode structure. As the drying temperature increases, surface and density of tomato thin-film is smoother and denser with thinner physical thickness. Chemical functional groups as a function of drying temperature is evaluated and correlated with the electrical property of thin film. A comparison between dark and UV (B and C) illumination with respect to the electrical property has been revealed and the observation has been linked to the active chemical compounds that controlling antioxidant activity in the tomato. By drying the tomato thin-film at 120°C, a self-powered (V = 0 V) photodetector that is able to selectively detecting UV-C can be obtained with external quantum efficiency (η) of 2.53 × 10-7%. While drying it at 140 °C, the detector is better in detecting UV-B when operating at either 5 or -5 V with η of 7.7384 × 10-6% and 8.87 × 10-6%, respectively. The typical response time for raising and falling for all samples are less than 0.3 s.

  7. Earth's UV Reflectivity Data from the Ozone Monitoring Instrument on EOS-Aura

    NASA Astrophysics Data System (ADS)

    Larko, D. E.; Mao, J.; Herman, J. R.; Huang, L.; Qin, W.; Labow, G. J.; Lloyd, S. A.; DeLand, M. T.

    2011-12-01

    The Lambert Equivalent Reflectivity (LER), derived from satellite ultraviolet (UV) radiance measurements, represents the equivalent scene reflectivity of the Earth's surface and atmosphere without Rayleigh scattering. It provides a better opportunity to quantify variations of the planetary reflectance and albedo associated with snow/ice, atmospheric aerosols and clouds, since UV reflectance is very low over most land surfaces and water. LER values at 340 nm from the Ozone Monitoring Instrument (OMI) on EOS-Aura have been generated as a new product from the OMI TO3 ozone retrieval algorithm and provided to users in HDF format. The wide field of view of OMI (~2200 km) provides complete global coverage every day with 13 km x 24 km resolution at nadir. These data are then mapped to 1 degree x 1 degree latitude-longitude grid as daily and monthly means for weather and climate studies. The OMI LER data set has been used to validate other UV LER data sets from NOAA and NASA polar orbiting satellites, and has been combined with these data sets to construct a continuous long-term data record of terrestrial UV reflectivity. This paper will present details about the data processing and format of the OMI LER product. Applications of this data set in global climate studies will be demonstrated and discussed in this presentation.

  8. Plasma Treatment to Remove Carbon from Indium UV Filters

    NASA Technical Reports Server (NTRS)

    Greer, Harold F.; Nikzad, Shouleh; Beasley, Matthew; Gantner, Brennan

    2012-01-01

    The sounding rocket experiment FIRE (Far-ultraviolet Imaging Rocket Experiment) will improve the science community fs ability to image a spectral region hitherto unexplored astronomically. The imaging band of FIRE (.900 to 1,100 Angstroms) will help fill the current wavelength imaging observation hole existing from approximately equal to 620 Angstroms to the GALEX band near 1,350 Angstroms. FIRE is a single-optic prime focus telescope with a 1.75-m focal length. The bandpass of 900 to 1100 Angstroms is set by a combination of the mirror coating, the indium filter in front of the detector, and the salt coating on the front of the detector fs microchannel plates. Critical to this is the indium filter that must reduce the flux from Lymanalpha at 1,216 Angstroms by a minimum factor of 10(exp -4). The cost of this Lyman-alpha removal is that the filter is not fully transparent at the desired wavelengths of 900 to 1,100 Angstroms. Recently, in a project to improve the performance of optical and solar blind detectors, JPL developed a plasma process capable of removing carbon contamination from indium metal. In this work, a low-power, low-temperature hydrogen plasma reacts with the carbon contaminants in the indium to form methane, but leaves the indium metal surface undisturbed. This process was recently tested in a proof-of-concept experiment with a filter provided by the University of Colorado. This initial test on a test filter showed improvement in transmission from 7 to 9 percent near 900 with no process optimization applied. Further improvements in this performance were readily achieved to bring the total transmission to 12% with optimization to JPL's existing process.

  9. Hybrid UV Imager Containing Face-Up AlGaN/GaN Photodiodes

    NASA Technical Reports Server (NTRS)

    Zheng, Xinyu; Pain, Bedabrata

    2005-01-01

    A proposed hybrid ultraviolet (UV) image sensor would comprise a planar membrane array of face-up AlGaN/GaN photodiodes integrated with a complementary metal oxide/semiconductor (CMOS) readout-circuit chip. Each pixel in the hybrid image sensor would contain a UV photodiode on the AlGaN/GaN membrane, metal oxide/semiconductor field-effect transistor (MOSFET) readout circuitry on the CMOS chip underneath the photodiode, and a metal via connection between the photodiode and the readout circuitry (see figure). The proposed sensor design would offer all the advantages of comparable prior CMOS active-pixel sensors and AlGaN UV detectors while overcoming some of the limitations of prior (AlGaN/sapphire)/CMOS hybrid image sensors that have been designed and fabricated according to the methodology of flip-chip integration. AlGaN is a nearly ideal UV-detector material because its bandgap is wide and adjustable and it offers the potential to attain extremely low dark current. Integration of AlGaN with CMOS is necessary because at present there are no practical means of realizing readout circuitry in the AlGaN/GaN material system, whereas the means of realizing readout circuitry in CMOS are well established. In one variant of the flip-chip approach to integration, an AlGaN chip on a sapphire substrate is inverted (flipped) and then bump-bonded to a CMOS readout circuit chip; this variant results in poor quantum efficiency. In another variant of the flip-chip approach, an AlGaN chip on a crystalline AlN substrate would be bonded to a CMOS readout circuit chip; this variant is expected to result in narrow spectral response, which would be undesirable in many applications. Two other major disadvantages of flip-chip integration are large pixel size (a consequence of the need to devote sufficient area to each bump bond) and severe restriction on the photodetector structure. The membrane array of AlGaN/GaN photodiodes and the CMOS readout circuit for the proposed image sensor would be fabricated separately.

  10. Cosmological signatures of a UV-conformal standard model.

    PubMed

    Dorsch, Glauber C; Huber, Stephan J; No, Jose Miguel

    2014-09-19

    Quantum scale invariance in the UV has been recently advocated as an attractive way of solving the gauge hierarchy problem arising in the standard model. We explore the cosmological signatures at the electroweak scale when the breaking of scale invariance originates from a hidden sector and is mediated to the standard model by gauge interactions (gauge mediation). These scenarios, while being hard to distinguish from the standard model at LHC, can give rise to a strong electroweak phase transition leading to the generation of a large stochastic gravitational wave signal in possible reach of future space-based detectors such as eLISA and BBO. This relic would be the cosmological imprint of the breaking of scale invariance in nature.

  11. Single-Shot Spectrally Resolved UV Rayleigh Scattering Measurements in High Speed Flow

    NASA Technical Reports Server (NTRS)

    Seasholtz, Richard G.

    1996-01-01

    A single-shot UV molecular Rayleigh scattering technique to measure velocity in high speed flow is described. The beam from an injection-seeded, frequency quadrupled Nd:YAG laser (266 nm) is focused to a line in a free air jet with velocities up to Mach 1.3. Rayleigh scattered light is imaged through a planar mirror Fabry-Perot interferometer onto a Charged Coupled Device (CCD) array detector. Some laser light is also simultaneously imaged through the Fabry-Perot to provide a frequency reference. Two velocity measurements are obtained from each image. Multiple-pulse data are also given. The Rayleigh scattering velocity data show good agreement with velocities calculated from isentropic flow relations.

  12. A general study of techniques for ultraviolet astrophysical studies on space vehicles

    NASA Technical Reports Server (NTRS)

    Moos, H. W.; Fastie, W. G.; Davidsen, A. F.

    1977-01-01

    Recent accomplishments in three areas of UV instrumentation for space astronomy are discussed. These areas include reliable UV photometry, sensitive photon-detection techniques, and precise telescope pointing. Calibration facilities for spectrometers designed to operate in the spectral regions above 1200 A and down to 400 A are described which employ a series of diodes calibrated against electron synchrotron radiation as well as other radiometric standards. Improvements in photon-detection sensitivity achieved with the aid of pulse-counting electronics and multispectral detectors are reported, and the technique of precise subarcsecond telescope pointing is briefly noted. Some observational results are presented which demonstrate the advantages and precision of the instruments and techniques considered.

  13. Study of the optical properties and the carbonaceous clusters in DAM-ADC solid state nuclear track detectors

    NASA Astrophysics Data System (ADS)

    Rammah, Y. S.; Abdalla, A. M.

    2017-12-01

    The optical properties of DAM-ADC solid state nuclear track detectors (SSNTDs) were investigated. Samples of DAM-ADC detector were irradiated at room temperature with gamma doses in the range of 100-500 kGy using 1.25 MeV 60Co source of dose rate 4 kGy/h. The optical characterization of these detectors have been studied through the measurements of UV-visible absorption spectra of blank and γ- irradiated samples. The optical energy band gaps, Eg for the detectors were obtained from the direct and the indirect allowed transitions in K-space using two methods (Tauc's model and absorption spectrum fitting (ASF) method). The absorbance of DAM-ADC detector was found to increase with increasing of the gamma absorbed dose. The width of the tail of localized states in the band gap, Eu was evaluated with the Urbach's method. The number of carbon atoms per conjugated length (N), the number of carbon atoms per cluster (M), and refractive index (n) for the present samples were determined. Both of the direct and the indirect band gaps of DAM-ADC detector decrease with increasing of the gamma absorbed dose. Urbach's energy decreased significantly for the detector. An increase in N, M, and n with increasing of the gamma absorbed dose was noticed. Results shed light on the effect of gamma irradiations of DAM-ADC SSNTDs to suitable industrial applications and to modify the optical properties through gamma-induced modifications of the polymer structure.

  14. Detection of In Vivo Foot and Ankle Implants by Walkthrough Metal Detectors.

    PubMed

    Chan, Jeremy Y; Mani, Sriniwasan B; Williams, Phillip N; O'Malley, Martin J; Levine, David S; Roberts, Matthew M; Ellis, Scott J

    2014-08-01

    Heightened security concerns have made metal detectors a standard security measure in many locations. While prior studies have investigated the detection rates of various hip and knee implants, none have looked specifically at the detection of foot and ankle implants in an in vivo model. Our goals were to identify which commonly used foot and ankle implants would be detected by walkthrough metal detectors both in vivo and ex vivo. Over a 7-month period, 153 weightbearing patients with foot and ankle hardware were recruited to walk through a standard airport metal detector at 3 different program settings (buildings, airports, and airports enhanced) with a base sensitivity of 165 (arbitrary units), as currently used by the Transportation Security Administration. The number of implants, location and type, as well as the presence of concomitant hardware outside of the foot and ankle were recorded. To determine the detection rate of common foot and ankle implants ex vivo, different hardware sets were walked through the detector at all 3 program settings. Seventeen patients were found to have detectable hardware at the buildings, airports, and airports enhanced settings. An additional 3 patients had hardware only detected at the airports enhanced setting. All 20 of these patients had concomitant metal implants outside of the foot and ankle from other orthopaedic procedures. All patients with foot and ankle implants alone passed through undetected. Seven hardware sets were detected ex vivo at the airports enhanced setting. Our results indicate that patients with foot and ankle implants alone are unlikely to be detected by walkthrough metal detectors at standard airport settings. When additional hardware is present from orthopaedic procedures outside of the foot and ankle, metal detection rates were higher. We believe that these results are important for surgeons in order to educate patients on how they might be affected when walking through a metal detector such as while traveling. Level II, prospective comparative study. © The Author(s) 2014.

  15. Method for detection of extremely low concentration

    DOEpatents

    Andresen, Brian D.; Miller, Fred S.

    2002-01-01

    An ultratrace detector system for hand-held gas chromatography having high sensitivity, for example, to emissions generated during production of weapons, biological compounds, drugs, etc. The detector system is insensitive to water, air, helium, argon, oxygen, and CO.sub.2. The detector system is basically composed of a hand-held capillary gas chromatography (GC), an insulated heated redox-chamber, a detection chamber, and a vapor trap. For example, the detector system may use gas phase redox reactions and spectral absorption of mercury vapor. The gas chromatograph initially separates compounds that percolate through a bed of heated mercuric oxide (HgO) in a silica--or other metal--aerogel material which acts as an insulator. Compounds easily oxidized by HgO liberate atomic mercury that subsequently pass through a detection chamber which includes a detector cell, such as quartz, that is illuminated with a 254 nm ultra-violet (UV) mercury discharge lamp which generates the exact mercury absorption bands that are used to detect the liberated mercury atoms. Atomic mercury strongly absorbs 254 nm energy is therefore a specific signal for reducing compounds eluting from the capillary GC, whereafter the atomic mercury is trapped for example, in a silicon-aerogel trap.

  16. Ashra (All-sky Survey High Resolution Air-shower detector)Current Status on Mauna Loa, Hawai`i

    NASA Astrophysics Data System (ADS)

    Hamilton, John; Fox, R. A.; Sasaki, M.; Asaoka, Y.; Ashra Collaboration

    2008-09-01

    Now in its third year of on-site activities, Ashra is commencing full testing of its array of Cherenkov and Nitrogen Fluorescence detectors. The All-sky Survey High Resolution Air-shower detector is located on the northern upper slopes of Mauna Loa at the 11,000 ft elevation level. Utilizing a clear view of 80% of the sky and an unobstructed view of Mauna Kea, anglular resolution of 1.2 arcmin, sensitive to the blue to UV light with the use of image intensifier and CMOS technology, Ashra is in a unique position for studying the sources of High Energy Cosmic Ray sources (GRB, etc) as well as potential observations of earth-grazing neutrino interactions. 2004 saw the successful deployment of a prototype detector on Haleakala, with confirmed detection of several GRBs. Since the summer of 2005, steady progress was made in constructing and installation of detectors and their weather-proofed housings. UH-Hilo undergraduate students provided summer interns for this international collaboration between ICRR Univ. Tokyo, Univ. Hawai`i-Hilo, Univ Hawai`i-Manoa, Ibaraki Univ., Toho Univ. Chiba Univ., Kanagawa Univ., Nagoya Univ. & Tokyo Institute of Technology.

  17. Qualification of coolants and cooling pipes for future high-energy-particle detectors

    NASA Astrophysics Data System (ADS)

    Ilie, Sorin; Tavlet, Marc

    2001-12-01

    In the next generation of high-energy-particle detectors to be installed at the Large Hadron Collider (LHC) at CERN, materials and components will be exposed to a significant level of ionising radiation. Silicon detectors and related electronics will have to be cooled down to -20 °C and therefore appropriate cooling fluids and cooling pipes have to be selected. Analytical methods such as UV-visible and FT-IR spectrometries, electronic microscopy and gas chromatography were used to characterise the radiation-induced effects on some organic coolants irradiated with both gamma and neutron fields. Some impurities were identified as a major source for radio-induced polymerisation and also for hydrofluoric acid (HF) evolution. Mechanical tests were performed to assess the operability of the rubber hoses and plastic pipes. Possible synergistic effects between the pipe material and the environment had to be considered.

  18. A new approach for direct imaging of Alpha radiation by using Micro Pattern Gas Detectors in SQS mode

    NASA Astrophysics Data System (ADS)

    Souri, R.; Negarestani, A.; Mahani, M.

    2018-03-01

    In this study, the design, simulation and construction of three micro pattern gas-detectors, THGEM, with different geometric dimensions are presented. Moreover, their ability of operation in SQS mode to determine the incident rays position without using any conventional imaging system is investigated. In the presence of UV absorbing gas mixtures, the proportional mode of the gas detector operation is followed by SQS mode as soon as the visible light column appears at the ray entrance location. In the method employed, each THGEM hole as an image pixel independent of other holes can operate in SQS mode with emerging a light column. As a consequence, it can be used for alpha beam imaging since the brightness of each hole at a certain voltage is proportional to the number of primary electrons entering the hole.

  19. Toward Directly-Deposited Optical Blocking Filters for High-performance, Back-illuminated Imaging X-ray Detectors

    NASA Astrophysics Data System (ADS)

    Bautz, Mark W.; Kissel, S. E.; Ryu, K.; Suntharalingam, V.

    2014-01-01

    Silicon X-ray detectors require optical blocking filters to prevent out-of-band (UV, visible and near-IR) radiation from corrupting the X-ray signal. Traditionally, blocking filters have been deposited on thin, free-standing membranes suspended over the detector. Free-standing filters are fragile, however, and in past instruments have required heavy and complex vacuum housings to protect them from acoustic loads during ground operations and launch. A directly-deposited blocking filter greatly simplifies the instrument and in principle permits better soft X-ray detection efficiency than a traditional free-standing filter. Directly-deposited filters have flown in previous generation instruments (e.g. the XMM/Newton Reflection Grating Spectrometer) but none has yet been demonstrated on a modern, high-performance back-illuminated X-ray CCD. We report here on the status of our NASA-funded Strategic Astrophysics Technology program to demonstrate such filters.

  20. GOES Sounder Instrument - NOAA Satellite Information System (NOAASIS);

    Science.gov Websites

    ground-based, balloon system. The Sounder has 4 sets of detectors (visible, long wave IR, medium wave IR , short wave IR). The incoming radiation passes through a set of filters before reaching the detectors concentric rings, one for each IR detector group. The outer ring contains 7 long wave filters, the middle

  1. 46 CFR Appendix D to Subpart C of... - Sampling and Analytical Methods for Benzene Monitoring-Measurement Procedures

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... samples are analyzed directly by high performance liquid chromatography (HPLC). Detection limits: 0.01% by... proper selection of HPLC parameters. 2.4. Samples must be free of any particulates that may clog the... clarification kit. 3. Apparatus 3.1. Liquid chromatograph equipped with a UV detector. 3.2. HPLC Column that...

  2. 46 CFR Appendix D to Subpart C of... - Sampling and Analytical Methods for Benzene Monitoring-Measurement Procedures

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... samples are analyzed directly by high performance liquid chromatography (HPLC). Detection limits: 0.01% by... proper selection of HPLC parameters. 2.4. Samples must be free of any particulates that may clog the... clarification kit. 3. Apparatus 3.1. Liquid chromatograph equipped with a UV detector. 3.2. HPLC Column that...

  3. 46 CFR Appendix D to Subpart C of... - Sampling and Analytical Methods for Benzene Monitoring-Measurement Procedures

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... samples are analyzed directly by high performance liquid chromatography (HPLC). Detection limits: 0.01% by... proper selection of HPLC parameters. 2.4. Samples must be free of any particulates that may clog the... clarification kit. 3. Apparatus 3.1. Liquid chromatograph equipped with a UV detector. 3.2. HPLC Column that...

  4. A Hybrid Readout Solution for GaN-Based Detectors Using CMOS Technology.

    PubMed

    Padmanabhan, Preethi; Hancock, Bruce; Nikzad, Shouleh; Bell, L Douglas; Kroep, Kees; Charbon, Edoardo

    2018-02-03

    Gallium nitride (GaN) and its alloys are becoming preferred materials for ultraviolet (UV) detectors due to their wide bandgap and tailorable out-of-band cutoff from 3.4 eV to 6.2 eV. GaN based avalanche photodiodes (APDs) are particularly suitable for their high photon sensitivity and quantum efficiency in the UV region and for their inherent insensitivity to visible wavelengths. Challenges exist however for practical utilization. With growing interests in such photodetectors, hybrid readout solutions are becoming prevalent with CMOS technology being adopted for its maturity, scalability, and reliability. In this paper, we describe our approach to combine GaN APDs with a CMOS readout circuit, comprising of a linear array of 1 × 8 capacitive transimpedance amplifiers (CTIAs), implemented in a 0.35 µm high voltage CMOS technology. Further, we present a simple, yet sustainable circuit technique to allow operation of APDs under high reverse biases, up to ≈80 V with verified measurement results. The readout offers a conversion gain of 0.43 µV/e - , obtaining avalanche gains up to 10³. Several parameters of the CTIA are discussed followed by a perspective on possible hybridization, exploiting the advantages of a 3D-stacked technology.

  5. Rapid Flow-Based Peptide Synthesis

    PubMed Central

    Simon, Mark D.; Heider, Patrick L.; Adamo, Andrea; Vinogradov, Alexander A.; Mong, Surin K.; Li, Xiyuan; Berger, Tatiana; Policarpo, Rocco L.; Zhang, Chi; Zou, Yekui; Liao, Xiaoli; Spokoyny, Alexander M.; Jensen, Klavs F.

    2014-01-01

    A flow-based solid phase peptide synthesis methodology that enables the incorporation of an amino acid residue every 1.8 minutes under automatic control, or every three minutes under manual control, is described. This is accomplished by passing a stream of reagent through a heat exchanger, into a low volume, low backpressure reaction vessel, and through a UV detector. These features enable the continuous delivery of heated solvents and reagents to the solid support at high flow rate, maintaining a maximal concentration of reagents in the reaction vessel, quickly exchanging reagents, and eliminating the need to rapidly heat reagents after they have been added to the vessel. The UV detector enables continuous monitoring of the process. To demonstrate the broad applicability and reliability of this method, it was employed in the total synthesis of a small protein, as well as dozens of peptides. The quality of the material obtained with this method is comparable to traditional batch methods, and, in all cases, the desired material was readily purifiable via RP-HPLC. The application of this method to the synthesis of the 113 residue B. amyloliquefaciens RNase and the 130 residue pE59 DARPin is described in the accompanying manuscript. PMID:24616230

  6. Anion-exchange high-performance liquid chromatography of water-soluble chromium (VI) and chromium (III) complexes in biological materials.

    PubMed

    Suzuki, Y

    1987-04-10

    A high-performance anion-exchange liquid chromatograph coupled to visible-range (370 nm) and UV (280 nm) detectors and an atomic-absorption spectrometer allowed the rapid determination of CrVI and/or complexes of CrIII in rat plasma, erythrocyte lysate and liver supernatant treated with CrVI or CrIII in vitro. CrVI in the eluates was determined using both the visible-range detector and atomic-absorption spectrometer (AAS). The detection limits of CrVI in standard solutions using these methods were 2 and 5 ng (signal-to-noise ratio = 2), respectively. Separations of the biological components and of CrIII complexes were monitored by UV and AAS analyses, respectively. Time-related decreases of CrVI accompanied by increases in CrIII complexes were observed, indicating the reduction of CrVI by some of the biological components. The reduction rates were considerably higher in the liver supernatant and erythrocyte lysate than in the plasma. These results indicate that the anion-exchange high-performance liquid chromatographic system is useful for simultaneous determination of CrVI and CrIII complexes in biological materials.

  7. Gettering of Residual Impurities by Ion Implantation Damage in Poly-AlN UV Diode Detectors

    NASA Astrophysics Data System (ADS)

    Khan, A. H.; Stacy, T.; Meese, J. M.

    1996-03-01

    UV diode detectors have been fabricated from oriented polycrystalline AlN grown on (111) n-type 3-15Ω-cm Si substrates by CVD using AlCl3 and ammonia with a hydrogen carrier gas at 760-800C, 40-45 torr and gas flow rates of 350, 120, and 120 sccm for hydrogen, ammonia and hydrogen over heated AlCl_3. Half of the AlN film of thickness 1.5-2.0 microns was masked off prior to ion implantation. Samples were ion-implanted at 5 kV with methane, nitrogen and argon to a dose of 5-6 x 10^18 ions/cm^2. The AlN was contacted with sputtered Au while the Si was contacted with evaporated Al. No annealing was performed. Rectification was obtained as a result of radiation damage in the AlN. SIMs analysis showed a reduction of oxygen, hydrogen, chlorine and carbon by several orders of magnitude and to a depth of several microns in the ion implanted samples compared to the masked samples. The quantum efficiency was 16nm uncorrected for reflection from the AlN and thin metal contact.

  8. Sample Selection for Training Cascade Detectors.

    PubMed

    Vállez, Noelia; Deniz, Oscar; Bueno, Gloria

    2015-01-01

    Automatic detection systems usually require large and representative training datasets in order to obtain good detection and false positive rates. Training datasets are such that the positive set has few samples and/or the negative set should represent anything except the object of interest. In this respect, the negative set typically contains orders of magnitude more images than the positive set. However, imbalanced training databases lead to biased classifiers. In this paper, we focus our attention on a negative sample selection method to properly balance the training data for cascade detectors. The method is based on the selection of the most informative false positive samples generated in one stage to feed the next stage. The results show that the proposed cascade detector with sample selection obtains on average better partial AUC and smaller standard deviation than the other compared cascade detectors.

  9. Optimized "detectors" for dynamics analysis in solid-state NMR

    NASA Astrophysics Data System (ADS)

    Smith, Albert A.; Ernst, Matthias; Meier, Beat H.

    2018-01-01

    Relaxation in nuclear magnetic resonance (NMR) results from stochastic motions that modulate anisotropic NMR interactions. Therefore, measurement of relaxation-rate constants can be used to characterize molecular-dynamic processes. The motion is often characterized by Markov processes using an auto-correlation function, which is assumed to be a sum of multiple decaying exponentials. We have recently shown that such a model can lead to severe misrepresentation of the real motion, when the real correlation function is more complex than the model. Furthermore, multiple distributions of motion may yield the same set of dynamics data. Therefore, we introduce optimized dynamics "detectors" to characterize motions which are linear combinations of relaxation-rate constants. A detector estimates the average or total amplitude of motion for a range of motional correlation times. The information obtained through the detectors is less specific than information obtained using an explicit model, but this is necessary because the information contained in the relaxation data is ambiguous, if one does not know the correct motional model. On the other hand, if one has a molecular dynamics trajectory, one may calculate the corresponding detector responses, allowing direct comparison to experimental NMR dynamics analysis. We describe how to construct a set of optimized detectors for a given set of relaxation measurements. We then investigate the properties of detectors for a number of different data sets, thus gaining an insight into the actual information content of the NMR data. Finally, we show an example analysis of ubiquitin dynamics data using detectors, using the DIFRATE software.

  10. Images of the future - Two decades in astronomy

    NASA Technical Reports Server (NTRS)

    Weistrop, D.

    1982-01-01

    Future instruments for the 100-10,000 A UV-wavelength region will require detectors with greater quantum efficiency, smaller picture elements, a greater wavelength range, and greater active area than those currently available. After assessing the development status and performance characteristics of vidicons, image tubes, electronographic cameras, digicons, silicon arrays and microchannel plate intensifiers presently employed by astronomical spacecraft, attention is given to such next-generation detectors as the Mosaicked Optical Self-scanned Array Imaging Camera, which consists of a photocathode deposited on the input side of a microchannel plate intensifier. The problems posed by the signal processing and data analysis requirements of the devices foreseen for the 21st century are noted.

  11. SU-E-I-51: Quantitative Assessment of X-Ray Imaging Detector Performance in a Clinical Setting - a Simple Approach Using a Commercial Instrument

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sjoeberg, J; Bujila, R; Omar, A

    2015-06-15

    Purpose: To measure and compare the performance of X-ray imaging detectors in a clinical setting using a dedicated instrument for the quantitative determination of detector performance. Methods: The DQEPro (DQE Instruments Inc., London, Ontario Canada) was used to determine the MTF, NPS and DQE using an IEC compliant methodology for three different imaging modalities: conventional radiography (CsI-based detector), general-purpose radioscopy (CsI-based detector), and mammography (a-Se based detector). The radiation qualities (IEC) RQA-5 and RQA-M-2 were used for the CsI-based and a-Se-based detectors, respectively. The DQEPro alleviates some of the difficulties associated with DQE measurements by automatically positioning test devices overmore » the detector, guiding the user through the image acquisition process and providing software for calculations. Results: A comparison of the NPS showed that the image noise of the a-Se detector was less correlated than the CsI detectors. A consistently higher performance was observed for the a-Se detector at all spatial frequencies (MTF: 0.97@0.25 cy/mm, DQE: 0.72@0.25 cy/mm) and the DQE drops off slower than for the CsI detectors. The CsI detector used for conventional radiography displayed a higher performance at low spatial frequencies compared to the CsI detector used for radioscopy (DQE: 0.65 vs 0.60@0.25 cy/mm). However, at spatial frequencies above 1.3 cy/mm, the radioscopy detector displayed better performance than the conventional radiography detector (DQE: 0.35 vs 0.24@2.00 cy/mm). Conclusion: The difference in the MTF, NPS and DQE that was observed for the two different CsI detectors and the a-Se detector reflect the imaging tasks that the different detector types are intended for. The DQEPro has made the determination and calculation of quantitative metrics of X-ray imaging detector performance substantially more convenient and accessible to undertake in a clinical setting.« less

  12. Optoelectronic device physics and technology of nitride semiconductors from the UV to the terahertz.

    PubMed

    Moustakas, Theodore D; Paiella, Roberto

    2017-10-01

    This paper reviews the device physics and technology of optoelectronic devices based on semiconductors of the GaN family, operating in the spectral regions from deep UV to Terahertz. Such devices include LEDs, lasers, detectors, electroabsorption modulators and devices based on intersubband transitions in AlGaN quantum wells (QWs). After a brief history of the development of the field, we describe how the unique crystal structure, chemical bonding, and resulting spontaneous and piezoelectric polarizations in heterostructures affect the design, fabrication and performance of devices based on these materials. The heteroepitaxial growth and the formation and role of extended defects are addressed. The role of the chemical bonding in the formation of metallic contacts to this class of materials is also addressed. A detailed discussion is then presented on potential origins of the high performance of blue LEDs and poorer performance of green LEDs (green gap), as well as of the efficiency reduction of both blue and green LEDs at high injection current (efficiency droop). The relatively poor performance of deep-UV LEDs based on AlGaN alloys and methods to address the materials issues responsible are similarly addressed. Other devices whose state-of-the-art performance and materials-related issues are reviewed include violet-blue lasers, 'visible blind' and 'solar blind' detectors based on photoconductive and photovoltaic designs, and electroabsorption modulators based on bulk GaN or GaN/AlGaN QWs. Finally, we describe the basic physics of intersubband transitions in AlGaN QWs, and their applications to near-infrared and terahertz devices.

  13. Optoelectronic device physics and technology of nitride semiconductors from the UV to the terahertz

    NASA Astrophysics Data System (ADS)

    Moustakas, Theodore D.; Paiella, Roberto

    2017-10-01

    This paper reviews the device physics and technology of optoelectronic devices based on semiconductors of the GaN family, operating in the spectral regions from deep UV to Terahertz. Such devices include LEDs, lasers, detectors, electroabsorption modulators and devices based on intersubband transitions in AlGaN quantum wells (QWs). After a brief history of the development of the field, we describe how the unique crystal structure, chemical bonding, and resulting spontaneous and piezoelectric polarizations in heterostructures affect the design, fabrication and performance of devices based on these materials. The heteroepitaxial growth and the formation and role of extended defects are addressed. The role of the chemical bonding in the formation of metallic contacts to this class of materials is also addressed. A detailed discussion is then presented on potential origins of the high performance of blue LEDs and poorer performance of green LEDs (green gap), as well as of the efficiency reduction of both blue and green LEDs at high injection current (efficiency droop). The relatively poor performance of deep-UV LEDs based on AlGaN alloys and methods to address the materials issues responsible are similarly addressed. Other devices whose state-of-the-art performance and materials-related issues are reviewed include violet-blue lasers, ‘visible blind’ and ‘solar blind’ detectors based on photoconductive and photovoltaic designs, and electroabsorption modulators based on bulk GaN or GaN/AlGaN QWs. Finally, we describe the basic physics of intersubband transitions in AlGaN QWs, and their applications to near-infrared and terahertz devices.

  14. In Situ Determination of Illegal Drugs in Oral Fluid by Portable Capillary Electrophoresis with Deep UV Excited Fluorescence Detection.

    PubMed

    Saar-Reismaa, Piret; Erme, Enn; Vaher, Merike; Kulp, Maria; Kaljurand, Mihkel; Mazina-Šinkar, Jekaterina

    2018-05-15

    The present study demonstrates the potential of a portable capillary electrophoresis (CE) instrument, coupled to deep UV fluorescence detector (FD) with a 230-255 nm excitation wavelength range, for the determination of the abuse of illegal drugs in oral fluids in situ. CE was introduced in this study due its exceptional power of separation and resolution, short analysis time, and ability for miniaturization for on-site assessment of different substances. The deep UV fluorescence detector was equipped with five interchangeable emission filters, in the emission wavelength range from 278 to 600 nm, and was successfully employed for determination of natively fluorescing illegal drugs, such as cocaine, cocaethylene, 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxeamphetamine (MDA), 3,4-methylenedioxy- N-ethylamphetamine (MDEA), para-methoxyamphetamine (PMA), para-methoxy- N-methylamphetamine (PMMA), amphetamine (AMP), methamphetamine (METH), tetrahydrocannabinol (THC) and cannabidiol (CBD). The developed FD showed impressive sensitivity. The instrumental detection limit was 0.5 μg/L for MDMA. It also showed broad linearity, up to 50 mg/L for MDMA. The noise CV% was 1.1% for an empty capillary and 0.6% for a capillary filled with acetonitrile. The portable CE-FD with developed electrophoretic methodologies was successfully utilized for the determination of illegal abuse of drugs during "Weekend" 2016 and 2017 Music Festivals (Estonia). Moreover, CE-FD can be employed for detection of other natively fluorescing compounds in the proposed range (e.g., for different phenolic compounds, BTEX, naphthalene derivatives, and others), significantly widening the applicability of developed CE-FD instrument.

  15. Liquid chromatographic determination of minocycline in brain-to-plasma distribution studies in the rat.

    PubMed

    Colovic, Milena; Caccia, Silvio

    2003-07-05

    An isocratic reversed-phase high-performance liquid chromatographic procedure was developed for the determination of minocycline in rat plasma and brain and applied to brain-to-blood (plasma) distribution studies. The procedure is based on isolation of the compound and the internal standard (either demeclocycline or tetracycline may be used) from plasma and brain constituents using the Oasis HLB cartridge, with satisfactory recovery and specificity, and separation on a Symmetry Shield RP8 (15 cm x 4.6 mm, 3.5 microm) column coupled with a UV detector set at 350 nm. The assay was linear over a wide range, with a lower limit of quantification of 50 ng ml(-1) or g(-1), using 0.2 ml of plasma and about 200 mg of brain tissue. Precision and accuracy were acceptable. In the rat minocycline crossed the blood-brain barrier slowly, achieving mean brain concentrations between 30 and 40% of the equivalent systemic exposure, regardless of the dose and route of administration.

  16. Kuipers sets up the EHS/TEPC Spectrometer and Detector Assembly in the SM

    NASA Image and Video Library

    2012-03-12

    ISS030-E-177101 (12 March 2012) --- European Space Agency astronaut Andre Kuipers, Expedition 30 flight engineer, sets up the Environmental Health System / Tissue Equivalent Proportional Counter (EHS/TEPC) spectrometer and detector assembly on panel 327 in the Zvezda Service Module of the International Space Station. The TEPC detector assembly is the primary radiation measurement tool on the space station.

  17. Liquid-purity monitor for the LUX-ZEPLIN dark matter search

    NASA Astrophysics Data System (ADS)

    Manalaysay, Aaron; Lux-Zeplin Collaboration

    2016-03-01

    The LUX-ZEPLIN (LZ) experiment will be the first liquid-xenon (LXe) dark matter search to feature a multi-tonne fiducial target. Drawing on the lessons learned in the LUX and ZEPLIN experiments, this next step will probe dark-matter candidates with unprecedented sensitivity. As these LXe detectors have grown larger, so too has the distance over which ionization electrons (from particle interactions) must be drifted through the liquid. Because of this, even minute levels of electronegative impurities can significantly attenuate the ionization signal, and must therefore be closely monitored. I will present the concept of a liquid-purity monitor which uses new and novel techniques, including state-of-the-art UV LEDs and low-work-function materials, and will measure levels of impurities in LZ's liquid circulation line in real time. This device will provide vital supplemental data to the roughly weekly in-situ purity measurements carried out within the detector's active volume, will greatly improve the resolution of the ionization channel in this detector, and will yield instant feedback in response to changing detector conditions.

  18. Photon-counting intensified random-access charge injection device

    NASA Astrophysics Data System (ADS)

    Norton, Timothy J.; Morrissey, Patrick F.; Haas, Patrick; Payne, Leslie J.; Carbone, Joseph; Kimble, Randy A.

    1999-11-01

    At NASA GSFC we are developing a high resolution solar-blind photon counting detector system for UV space based astronomy. The detector comprises a high gain MCP intensifier fiber- optically coupled to a charge injection device (CID). The detector system utilizes an FPGA based centroiding system to locate the center of photon events from the intensifier to high accuracy. The photon event addresses are passed via a PCI interface with a GPS derived time stamp inserted per frame to an integrating memory. Here we present imaging performance data which show resolution of MCP tube pore structure at an MCP pore diameter of 8 micrometer. This data validates the ICID concept for intensified photon counting readout. We also discuss correction techniques used in the removal of fixed pattern noise effects inherent in the centroiding algorithms used and present data which shows the local dynamic range of the device. Progress towards development of a true random access CID (RACID 810) is also discussed and astronomical data taken with the ICID detector system demonstrating the photon event time-tagging mode of the system is also presented.

  19. Flexible Photodiodes Based on Nitride Core/Shell p–n Junction Nanowires

    PubMed Central

    2016-01-01

    A flexible nitride p-n photodiode is demonstrated. The device consists of a composite nanowire/polymer membrane transferred onto a flexible substrate. The active element for light sensing is a vertical array of core/shell p–n junction nanowires containing InGaN/GaN quantum wells grown by MOVPE. Electron/hole generation and transport in core/shell nanowires are modeled within nonequilibrium Green function formalism showing a good agreement with experimental results. Fully flexible transparent contacts based on a silver nanowire network are used for device fabrication, which allows bending the detector to a few millimeter curvature radius without damage. The detector shows a photoresponse at wavelengths shorter than 430 nm with a peak responsivity of 0.096 A/W at 370 nm under zero bias. The operation speed for a 0.3 × 0.3 cm2 detector patch was tested between 4 Hz and 2 kHz. The −3 dB cutoff was found to be ∼35 Hz, which is faster than the operation speed for typical photoconductive detectors and which is compatible with UV monitoring applications. PMID:27615556

  20. Quantitation of underivatized branched-chain amino acids in sport nutritional supplements by capillary electrophoresis with direct or indirect UV absorbance detection.

    PubMed

    Qiu, Jun; Wang, Jinhao; Xu, Zhongqi; Liu, Huiqing; Ren, Jie

    2017-01-01

    The branched-chain amino acids (BCAAs) including leucine (Leu), isoleucine (Ile) and valine (Val) play a pivotal role in the human body. Herein, we developed capillary electrophoresis (CE) coupled with conventional UV detector to quantify underivatized BCAAs in two kinds of sport nutritional supplements. For direct UV detection at 195 nm, the BCAAs (Leu, two enantiomers of Ile and Val) were separated in a background electrolyte (BGE) consisting of 40.0 mmol/L sodium tetraborate, and 40.0 mmol/L β-cyclodextrin (β-CD) at pH 10.2. In addition, the indirect UV detection at 264 nm was achieved in a BGE of 2.0 mmol/L Na2HPO4, 10.0 mmol/L p-aminosalicylic acid (PAS) as UV absorbing probe, and 40.0 mmol/L β-CD at pH 12.2. The β-CD significantly benefited the isomeric separation of Leu, L- and D-Ile. The optimal conditions allowed the LODs (limit of detections) of direct and indirect UV absorption detection to be tens μmol/L level, which was comparable to the reported CE inline derivatization method. The RSDs (relative standard deviations) of migration time and peak area were less than 0.91% and 3.66% (n = 6). Finally, CE with indirect UV detection method was applied for the quantitation of BCAAs in two commercial sport nutritional supplements, and good recovery and precision were obtained. Such simple CE method without tedious derivatization process is feasible of quality control and efficacy evaluation of the supplemental proteins.

  1. Catalogue of UV sources in the Galaxy

    NASA Astrophysics Data System (ADS)

    Beitia-Antero, L.; Gómez de Castro, A. I.

    2017-03-01

    The Galaxy Evolution Explorer (GALEX) ultraviolet (UV) database contains the largest photometric catalogue in the ultraviolet range; as a result GALEX photometric bands, Near UV band (NUV) and the Far UV band (FUV), have become standards. Nevertheless, the GALEX catalogue does not include bright UV sources due to the high sensitivity of its detectors, neither sources in the Galactic plane. In order to extend the GALEX database for future UV missions, we have obtained synthetic FUV and NUV photometry using the database of UV spectra generated by the International Ultraviolet Explorer (IUE). This database contains 63,755 spectra in the low dispersion mode (λ / δ λ ˜ 300) obtained during its 18-year lifetime. For stellar sources in the IUE database, we have selected spectra with high Signal-To-NoiseRatio (SNR) and computed FUV and NUV magnitudes using the GALEX transmission curves along with the conversion equations between flux and magnitudes provided by the mission. Besides, we have performed variability tests to determine whether the sources were variable (during the IUE observations). As a result, we have generated two different catalogues: one for non-variable stars and another one for variable sources. The former contains FUV and NUV magnitudes, while the latter gives the basic information and the FUV magnitude for each observation. The consistency of the magnitudes has been tested using White Dwarfs contained in both GALEX and IUE samples. The catalogues are available through the Centre des Donées Stellaires. The sources are distributed throughout the whole sky, with a special coverage of the Galactic plane.

  2. Quantitation of underivatized branched-chain amino acids in sport nutritional supplements by capillary electrophoresis with direct or indirect UV absorbance detection

    PubMed Central

    Liu, Huiqing; Ren, Jie

    2017-01-01

    The branched-chain amino acids (BCAAs) including leucine (Leu), isoleucine (Ile) and valine (Val) play a pivotal role in the human body. Herein, we developed capillary electrophoresis (CE) coupled with conventional UV detector to quantify underivatized BCAAs in two kinds of sport nutritional supplements. For direct UV detection at 195 nm, the BCAAs (Leu, two enantiomers of Ile and Val) were separated in a background electrolyte (BGE) consisting of 40.0 mmol/L sodium tetraborate, and 40.0 mmol/L β-cyclodextrin (β-CD) at pH 10.2. In addition, the indirect UV detection at 264 nm was achieved in a BGE of 2.0 mmol/L Na2HPO4, 10.0 mmol/L p-aminosalicylic acid (PAS) as UV absorbing probe, and 40.0 mmol/L β-CD at pH 12.2. The β-CD significantly benefited the isomeric separation of Leu, L- and D-Ile. The optimal conditions allowed the LODs (limit of detections) of direct and indirect UV absorption detection to be tens μmol/L level, which was comparable to the reported CE inline derivatization method. The RSDs (relative standard deviations) of migration time and peak area were less than 0.91% and 3.66% (n = 6). Finally, CE with indirect UV detection method was applied for the quantitation of BCAAs in two commercial sport nutritional supplements, and good recovery and precision were obtained. Such simple CE method without tedious derivatization process is feasible of quality control and efficacy evaluation of the supplemental proteins. PMID:28640882

  3. The effectiveness of UV-C radiation for facility-wide environmental disinfection to reduce health care-acquired infections.

    PubMed

    Napolitano, Nathanael A; Mahapatra, Tanmay; Tang, Weiming

    2015-12-01

    Health care-acquired infections (HAIs) constitute an increasing threat for patients worldwide. Potential contributors of HAIs include environmental surfaces in health care settings, where ultraviolet-C radiation (UV-C) is commonly used for disinfection. This UV-C intervention-based pilot study was conducted in a hospital setting to identify any change in the incidence of HAIs before and after UV-C intervention, and to determine the effectiveness of UV-C in reducing pathogens. In a hospital in Culver City, CA, during 2012-2013, bactericidal doses of UV-C radiation (254 nm) were delivered through a UV-C-based mobile environmental decontamination unit. The UV-C dosing technology and expertise of the specifically trained personnel were provided together as a dedicated service model by a contracted company. The incidence of HAIs before and after the intervention period were determined and compared. The dedicated service model dramatically reduced HAIs (incidence difference, 1.3/1000 patient-days, a 34.2% reduction). Reductions in the total number and incidence proportions (28.8%) of HAIs were observed after increasing and maintaining the coverage of UV-C treatments. The dedicated service model was found to be effective in decreasing the incidence of HAIs, which could reduce disease morbidity and mortality in hospitalized patients. This model provides a continuously monitored and frequently UV-C-treated patient environment. This approach to UV-C disinfection was associated with a decreased incidence of HAIs. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosch, R.; Trosseille, C.; Caillaud, T.

    The Laser Megajoule (LMJ) facility located at CEA/CESTA started to operate in the early 2014 with two quadruplets (20 kJ at 351 nm) focused on target for the first experimental campaign. We present here the first set of gated x-ray imaging (GXI) diagnostics implemented on LMJ since mid-2014. This set consists of two imaging diagnostics with spatial, temporal, and broadband spectral resolution. These diagnostics will give basic measurements, during the entire life of the facility, such as position, structure, and balance of beams, but they will also be used to characterize gas filled target implosion symmetry and timing, to studymore » x-ray radiography and hydrodynamic instabilities. The design requires a vulnerability approach, because components will operate in a harsh environment induced by neutron fluxes, gamma rays, debris, and shrapnel. Grazing incidence x-ray microscopes are fielded as far as possible away from the target to minimize potential damage and signal noise due to these sources. These imaging diagnostics incorporate microscopes with large source-to-optic distance and large size gated microchannel plate detectors. Microscopes include optics with grazing incidence mirrors, pinholes, and refractive lenses. Spatial, temporal, and spectral performances have been measured on x-ray tubes and UV lasers at CEA-DIF and at Physikalisch-Technische Bundesanstalt BESSY II synchrotron prior to be set on LMJ. GXI-1 and GXI-2 designs, metrology, and first experiments on LMJ are presented here.« less

  5. High pressure optical combustion probe

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woodruff, S.D.; Richards, G.A.

    1995-06-01

    The Department of Energy`s Morgantown Energy Technology Center has developed a combustion probe for monitoring flame presence and heat release. The technology involved is a compact optical detector of the OH radical`s UV fluorescence. The OH Monitor/Probe is designed to determine the flame presence and provide a qualitative signal proportional to the flame intensity. The probe can be adjusted to monitor a specific volume in the combustion zone to track spatial fluctuations in the flame. The probe is capable of nanosecond time response and is usually slowed electronically to fit the flame characteristics. The probe is a sapphire rod inmore » a stainless steel tube which may be inserted into the combustion chamber and pointed at the flame zone. The end of the sapphire rod is retracted into the SS tube to define a narrow optical collection cone. The collection cone may be adjusted to fit the experiment. The fluorescence signal is collected by the sapphire rod and transmitted through a UV transmitting, fused silica, fiber optic to the detector assembly. The detector is a side window photomultiplier (PMT) with a 310 run line filter. A Hamamatsu photomultiplier base combined with a integral high voltage power supply permits this to be a low voltage device. Electronic connections include: a power lead from a modular DC power supply for 15 VDC; a control lead for 0-1 volts to control the high voltage level (and therefore gain); and a lead out for the actual signal. All low voltage connections make this a safe and easy to use device while still delivering the sensitivity required.« less

  6. Development of an online UV-visible microspectrophotometer for a macromolecular crystallography beamline.

    PubMed

    Shimizu, Nobutaka; Shimizu, Tetsuya; Baba, Seiki; Hasegawa, Kazuya; Yamamoto, Masaki; Kumasaka, Takashi

    2013-11-01

    Measurement of the UV-visible absorption spectrum is a convenient technique for detecting chemical changes of proteins, and it is therefore useful to combine spectroscopy and diffraction studies. An online microspectrophotometer for the UV-visible region was developed and installed on the macromolecular crystallography beamline, BL38B1, at SPring-8. This spectrophotometer is equipped with a difference dispersive double monochromator, a mercury-xenon lamp as the light source, and a photomultiplier as the detector. The optical path is mostly constructed using mirrors, in order to obtain high brightness in the UV region, and the confocal optics are assembled using a cross-slit diaphragm like an iris to eliminate stray light. This system can measure optical densities up to a maximum of 4.0. To study the effect of radiation damage, preliminary measurements of glucose isomerase and thaumatin crystals were conducted in the UV region. Spectral changes dependent on X-ray dose were observed at around 280 nm, suggesting that structural changes involving Trp or Tyr residues occurred in the protein crystal. In the case of the thaumatin crystal, a broad peak around 400 nm was also generated after X-ray irradiation, suggesting the cleavage of a disulfide bond. Dose-dependent spectral changes were also observed in cryo-solutions alone, and these changes differed with the composition of the cryo-solution. These responses in the UV region are informative regarding the state of the sample; consequently, this device might be useful for X-ray crystallography.

  7. Tracking the NOvA Detectors' Performance

    NASA Astrophysics Data System (ADS)

    Psihas, Fernanda; NOvA Collaboration

    2016-03-01

    The NOvA experiment measures long baseline νμ -->νe oscillations in Fermilab's NuMI beam. We employ two detectors equipped with over 10 thousand sets of data-taking electronics; avalanche photo diodes and front end boards which collect and process the scintillation signal from particle interactions within the detectors. These sets of electronics -as well as the systems which power and cool them- must be monitored and maintained at precise working conditions to ensure maximal data-taking uptime, good data quality and a lasting life for our detectors. This poster describes the automated systems used on NOvA to simultaneously monitor our data quality, diagnose hardware issues, track our performance and coordinate maintenance for the detectors.

  8. Cryogenic radiometers and intensity-stabilized lasers for Eos radiometric calibrations

    NASA Technical Reports Server (NTRS)

    Foukal, P.; Hoyt, C.; Jauniskis, L.

    1991-01-01

    Liquid helium-cooled electrical substitution radiometers (ESRs) provide irradiance standards with demonstrated absolute accuracy at the 0.01 percent level, spectrally flat response between the UV and IR, and sensitivity down to 0.1 nW/sq cm. We describe an automated system developed for NASA - Goddard Space Flight Center, consisting of a cryogenic ESR illuminated by servocontrolled laser beams. This system is designed to provide calibration of single-element and array detectors over the spectral range between 257nm in the UV to 10.6 microns in the IR. We also describe a cryogenic ESR optimized for black body calibrations that has been installed at NIST, and another that is under construction for calibrations of the CERES scanners planned for Eos.

  9. Detecting technology of biophotons

    NASA Astrophysics Data System (ADS)

    Ma, Junfu; Zhu, Zhaohui; Zhu, Yanbin

    2002-03-01

    A key technique of detecting the ultra-weak photon emission from biological system (UPE) is to change the light signal of an extremely weak level into electric signal of a considerable level when the photo-electric detecting system were be applied. This paper analyzed the difficult for detecting the ultra-weak photon emission from biological system (UPE) mainly is in the absence of high sensitivity detector in UV-visible-infra spectra region. An experimental setup for testing UPE in different spectral region was designed. Using the experimental setup the test data of different several spectral regions from 300 nm to 1060 nm has were tested. The test result show the UPE of living biological system exists in wide spectra region from UV- visible to infrared.

  10. CUBES: cassegrain U-band Brazil-ESO spectrograph

    NASA Astrophysics Data System (ADS)

    Barbuy, B.; Bawden Macanhan, V.; Bristow, P.; Castilho, B.; Dekker, H.; Delabre, B.; Diaz, M.; Gneiding, C.; Kerber, F.; Kuntschner, H.; La Mura, G.; Maciel, W.; Meléndez, J.; Pasquini, L.; Pereira, C. B.; Petitjean, P.; Reiss, R.; Siqueira-Mello, C.; Smiljanic, R.; Vernet, J.

    2014-11-01

    CUBES is a high-efficiency, medium-resolution ( R˜20,000) ground based UV (300-400 nm) spectrograph, to be installed in the cassegrain focus of one of ESO's VLT unit telescopes in 2017/18. The CUBES project is a joint venture between ESO and IAG/USP, and LNA/MCTI. CUBES will provide access to a wealth of new and relevant information for stellar as well as extragalactic sources. Main science cases include the study of beryllium and heavy elements in metal-poor stars, the direct determination of carbon, nitrogen and oxygen abundances by study of molecular bands in the UV range, as well as the study of active galactic nuclei and the quasar absorption lines. With a streamlined modern instrument design, high efficiency dispersing elements and UV-sensitive detectors, it will give a significant gain in sensitivity over existing ground based medium-high resolution spectrographs, enabling vastly increased sample sizes accessible to the astronomical community. We present here a brief overview of the project including the status, science cases and a discussion of the design options.

  11. WFC3 UVIS Pixel-to-Pixel QE Variations via Internal Flats Monitor

    NASA Astrophysics Data System (ADS)

    Bajaj, Varun

    2016-10-01

    The UVIS detector has a population of pixels that exhibit anomalous QE variations between anneals, characterized by a sensitivity loss that is greater in the blue than in the red. This population is randomly distributed, with evidence of clustering behavior in the UV, and is seemingly unique for each anneal cycle. This program, a continuation of cycle 23 program 14389, will aim to constrain the maximum low-sensitivity population existing before an anneal in both the UV and Visible filters. To monitor the UV behavior, internal flats with the D2 lamp will be taken through F225W and F336W. To monitor the behavior in the Visible filters, internal flats with the tungsten lamp will be taken a week before the anneal, when the population of anomalous pixels is the greatest. Internal flats with the Tungsten lamp will be taken to monitor the population in the visible filters, with data taken the week before the anneal to sample the maximum population of anomalous pixels.

  12. Piezo-phototronic effect enhanced UV photodetector based on CuI/ZnO double-shell grown on flexible copper microwire.

    PubMed

    Liu, Jingyu; Zhang, Yang; Liu, Caihong; Peng, Mingzeng; Yu, Aifang; Kou, Jinzong; Liu, Wei; Zhai, Junyi; Liu, Juan

    2016-12-01

    In this work, we present a facile, low-cost, and effective approach to fabricate the UV photodetector with a CuI/ZnO double-shell nanostructure which was grown on common copper microwire. The enhanced performances of Cu/CuI/ZnO core/double-shell microwire photodetector resulted from the formation of heterojunction. Benefiting from the piezo-phototronic effect, the presentation of piezocharges can lower the barrier height and facilitate the charge transport across heterojunction. The photosensing abilities of the Cu/CuI/ZnO core/double-shell microwire detector are investigated under different UV light densities and strain conditions. We demonstrate the I-V characteristic of the as-prepared core/double-shell device; it is quite sensitive to applied strain, which indicates that the piezo-phototronic effect plays an essential role in facilitating charge carrier transport across the CuI/ZnO heterojunction, then the performance of the device is further boosted under external strain.

  13. Overview of detector technologies for EO/IR sensing applications

    NASA Astrophysics Data System (ADS)

    Sood, Ashok K.; Zeller, John W.; Welser, Roger E.; Puri, Yash R.; Lewis, Jay S.; Dhar, Nibir K.; Wijewarnasuriya, Priyalal

    2016-05-01

    Optical sensing technology is critical for optical communication, defense and security applications. Advances in optoelectronics materials in the UV, Visible and Infrared, using nanostructures, and use of novel materials such as CNT and Graphene have opened doors for new approaches to apply device design methodology that are expected to offer enhanced performance and low cost optical sensors in a wide range of applications. This paper is intended to review recent advancements and present different device architectures and analysis. The chapter will briefly introduce the basics of UV and Infrared detection physics and various wave bands of interest and their characteristics [1, 2] We will cover the UV band (200-400 nm) and address some of the recent advances in nanostructures growth and characterization using ZnO/MgZnO based technologies and their applications. Recent advancements in design and development of CNT and Graphene based detection technologies have shown promise for optical sensor applications. We will present theoretical and experimental results on these device and their potential applications in various bands of interest.

  14. Cryogenic gaseous photomultipliers and liquid hole- multipliers: advances in THGEM-based sensors for future noble-liquid TPCs

    NASA Astrophysics Data System (ADS)

    Arazi, L.; Coimbra, A. E. C.; Erdal, E.; Israelashvili, I.; Rappaport, M. L.; Shchemelinin, S.; Vartsky, D.; dos Santos, J. M. F.; A, Breskin

    2015-11-01

    Dual-phase noble-liquid TPCs are presently the most sensitive instruments for direct dark matter detection. Scaling up existing ton-scale designs to the multi-ton regime may prove to be technologically challenging. This includes both large-area coverage with affordable high-QE UV-photon detectors, and maintaining high precision in measuring the charge and light signals of rare events with keV-scale energy depositions. We present our recent advances in two complementary approaches to these problems: large-area cryogenic gaseous photomultipliers (GPM) for UV-photon detection, and liquid-hole multipliers (LHM) that provide electroluminescence light in response to ionization electrons and primary scintillation photons, using perforated electrodes immersed within the noble liquid. Results from a 10 cm diameter GPM coupled to a dual-phase liquid- xenon TPC demonstrate the feasibility of recording - for the first time - both primary (“S1”) and secondary (“S2”) scintillation signals, over a very broad dynamic range. The detector, comprising a triple-THGEM structure with CsI on the first element, has been operating stably at 180 K with gains larger than 105; it provided high single-photon detection efficiency - in the presence of massive alpha-particle induced S2 signals; S1 scintillation signals were recorded with time resolutions of 1.2 ns (RMS). Results with the LHM operated in liquid xenon yielded large photon gains, with a pulse-height resolution of 11% (RMS) for alpha-particle induced S2 signals. The detector response was stable over several months. The response of the S2 signals to rapid changes in pressure lead to the conclusion that the underlying mechanism for S2 light is electroluminescence in xenon bubbles trapped below the immersed THGEM electrode. Both studies have the potential of paving the way towards new designs of dual- and single-phase noble-liquid TPCs that could simplify the conception of future multi-ton detectors of dark matter and other rare events.

  15. Penetration of UV Radiation in the Earth's Oceans

    NASA Technical Reports Server (NTRS)

    Mitchell, B. Greg; Lubin, Dan

    2005-01-01

    This project was a collaboration between SIO/UCSD and NASA/GSFC to develop a global estimation of the penetration of UV light into open ocean waters, and into coastal waters. We determined the ocean UV reflectance spectra seen by satellites above the atmosphere by combining existing sophisticated radiative transfer models with in situ UV Visible data sets to improve coupled radiance estimates both underwater and within the atmosphere. Results included improved estimates of surface spectral irradiance, 0.3-1.0 micron, and estimates of photosynthetic inhibition, DNA mutation, and CO production. Data sets developed under this proposal have been made publicly available via submission to the SeaWiFS Bio-Optical Archive and Storage System. Numerous peer-reviewed publications and conference proceedings and abstracts resulted from the work supported by this research award.

  16. UHPLC-UV method for the determination of flavonoids in dietary supplements and for evaluation of their antioxidant activities.

    PubMed

    Magiera, Sylwia; Baranowska, Irena; Lautenszleger, Anna

    2015-01-01

    A simple and rapid ultra-high performance liquid chromatographic (UHPLC) method coupled with an ultraviolet detector (UV) has been developed and validated for the separation and determination of 14 major flavonoids ((±)-catechin, (-)-epicatechin, glycitin, (-)-epicatechin gallate, rutin, quercitrin, hesperidine, neohesperidine, daidzein, glycitein, quercetin, genistein, hesperetin, and biochanin A) in herbal dietary supplements. The flavonoids have been separated on a Chromolith Fast Gradient Monolithic RP-18e column utilizing a mobile phase composed of 0.05% trifluoroacetic acid in water and acetonitrile in gradient elution mode. Under these conditions, flavonoids were separated in a 5 min run. The selectivity of the developed UHPLC-UV method was confirmed by comparison with ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) analysis. The validation parameters such as linearity, sensitivity, precision, and accuracy were found to be highly satisfactory. The optimized method was applied to determination of flavonoids in different dietary supplements. Additionally, the developed HPLC-UV method combined with 2,2-diphenyl-1-picrylhydrazyl radical (DPPH) assay was used in the evaluation of antioxidant activity of the selected flavonoids. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Reduced Noise UV Enhancement of Etch Rates for Nuclear Tracks in CR-39

    NASA Astrophysics Data System (ADS)

    Sheets, Rebecca; Clarkson, David; Ume, Rubab; Regan, Sean; Sangster, Craig; Padalino, Stephen; McLean, James

    2016-10-01

    The use of CR-39 plastic as a Solid State Nuclear Track Detector is an effective technique for obtaining data in high-energy particle experiments including inertial confinement fusion. To reveal particle tracks after irradiation, CR-39 is chemically etched in NaOH at 80°C for 6 hours, producing micron-scale signal pits at the nuclear track sites. Using CR-39 irradiated with 5.4 MeV alpha particles and 1.0 MeV protons, we show that exposing the CR-39 to high intensity UV light before etching, with wavelengths between 240 nm and 350 nm, speeds the etch process. Elevated temperatures during UV exposure amplifies this effect, with etch rates up to 50% greater than unprocessed conditions. CR-39 pieces exposed to UV light and heat can also exhibit heightened levels of etch-induced noise (surface features not caused by nuclear particles). By illuminating the CR-39 from the side opposite to the tracks, a similar level of etch enhancement was obtained with little to no noise. The effective wavelength range is reduced, due to strong attenuation of shorter wavelengths. Funded in part by a LLE contract through the DOE.

  18. Reduced graphene Oxide/ZnO nanostructures based rectifier diode

    NASA Astrophysics Data System (ADS)

    Bhatnagar, Sameeksha; Kumar, Ravi; Sharma, Monika; Kuanr, Bijoy K.

    2017-05-01

    We report on the fabrication and characterization of graphene oxide and reduced graphene oxide/ZnO nanostructures on ITO-coated glass substrates for the rectification properties of a heterojunction device. The composites of GO/ZnO and rGO/ZnO were synthesized by the modified Hummers method followed by annealing process in N2 and H2 ambient atmosphere at various temperatures. The structural and compositional analysis of the composite material have been investigated using X-ray diffraction spectroscopy and Raman spectroscopy. The optical properties of the composite films were studied by UV-visible spectroscopy and the band-gap was obtained by Tauc's plot. The band-gap reduces to 2.4 eV for the composite film as compared to ZnO film 3.26 eV. The I-V characteristics of ZnO thin films and rGO/ZnO films were done for different light conditions viz dark, ambient light and UV-illumination. It has been observed that the threshold voltage decreases when the sample was placed in UV-illumination. A direct variation in photo-response is revealed with the bias voltage as well as UV illumination. The fabricated device could be used as an Ultraviolet Photo-detector.

  19. VizieR Online Data Catalog: Solar spectral irradiance (Marchenko+, 2014)

    NASA Astrophysics Data System (ADS)

    Marchenko, S. V.; Deland, M. T.

    2017-03-01

    Combining the contemporaneous Ozone Monitoring Instrument (OMI) and GOME-2 observations with the records from previous solar cycles, we construct the normalized (to the Mg II doublet at 280 nm) solar variability spectrum in the 170-795 nm spectral range, which could be used in combination with a reference spectrum (e.g., Thuillier et al. 2004, Solar Variability and its Effects on Climate (Geophysical Monograph 141), ed. J. M. Pup et al. (Washington, DC: AGU Geophysical Monograph Series), 171) to reproduce a dynamical solar spectrum at any epoch.The remote-sensing OMI (part of the Aura instrumental suite; Levelt et al., 2006ITGRS..44.1093L) has collected information about trace gases in the Earth's atmosphere since 2004 July. OMI comprises three different spectral channels, UV1 (264-311 nm spectral domain, resolution δλ = 0.63 nm), UV2 (307-383 nm, δλ = 0.42 nm), and VIS (349-504 nm, δλ = 0.63 nm), each acquiring data through partially shared optical pathways (Dobber et al., 2006ITGRS..44.1209D). The UV1 and UV2 light falls on the same CCD detector while VIS spectra are recorded by a different CCD. (1 data file).

  20. Optical detectors based on thermoelastic effect in crystalline quartz

    NASA Astrophysics Data System (ADS)

    Chelibanov, V. P.; Ishanin, G. G.

    2015-06-01

    Optical detectors developed on base of thermo elastic effect In quartz crystalline (PTEK) attributed to the thermal detectors group. Such detectors occurred very effective for the registration of pulsed light energy or power of harmonically modulated laser radiation flux in a wide spectral (from UV to far IR) and dynamic ranges (from 10-6 to 300 W / cm2 with cooling) with a time constant up to10-6 seconds. When exposed to electromagnetic radiation occurs at the receiver thermal field which causes mechanical stress in the transient crystalline quartz, which in turn leads to a change in the polarization of crystalline quartz and, as a consequence, to an electric potential difference at the electrodes (the front surface with a conductive coating and damper). The capacitive characteristic of the detector, based on a thermo elastic effect in crystalline quartz, eliminates the possibility of working with constant flow of radiation, which also affects at the frequency response of the detector, since the potential difference appearance in the piezoelectric plate depends on the direction of the forces relative to the axes X, Y, Z of the crystal. Therefore, a certain choice of orientation of the receiving element is necessary in accordance with the physical properties of crystalline quartz. In this paper, a calculation of the sensitivity and frequency characteristics of optical detectors based on the thermo elastic effect in crystalline quartz at the harmonic effects of electromagnetic radiation flux are reported.

  1. Analytical characterization of engineered ZnO nanoparticles relevant for hazard assessment

    NASA Astrophysics Data System (ADS)

    Bragaru, Adina; Kusko, Mihaela; Vasile, Eugeniu; Simion, Monica; Danila, Mihai; Ignat, Teodora; Mihalache, Iuliana; Pascu, Razvan; Craciunoiu, Florea

    2013-01-01

    The optoelectronic properties of zinc oxide nanoparticles (ZnO-NPs) have determined development of novel applications in catalysis, paints, wave filters, UV detectors, transparent conductive films, solar cells, or sunscreens. While the immediate advantages of using nano-ZnO in glass panel coatings and filter screens for lamps, as protecting products against bleaching, have been demonstrated, the potential environmental effect of the engineered NPs and the associated products was not fully estimated; this issue being of utmost importance, as these materials will be supplied to the market in quantities of tons per year, equating to thousands of square meters. In this study, ZnO-NPs with commercial name Zincox™ have been subjected to a comprehensive characterization, relevant for hazard assessment, using complementary physico-chemical methods. Therefore, the morphological investigations have been corroborated with XRD pattern analyses and UV-Vis absorption related properties resulting an excellent correlation between the geometrical sizes revealed by microscopy (8.0-9.0 nm), and, respectively, the crystallite size (8.2-9.5 nm) and optical size (7.8 nm) calculated from the last two techniques' data. Furthermore, the hydrodynamic diameter of ZnO-NPs and stability of aqueous dispersions with different concentration of nanoparticles have been analyzed as function of significant solution parameters, like concentration, pH and solution ionic strength. The results suggest that solution chemistry exerts a strong influence on ZnO dissolution stability, the complete set of analyses providing useful information toward better control of dosage during biotoxicological tests.

  2. SMOKE: Characterization of Smoke Particulate for Spacecraft Fire Detection

    NASA Technical Reports Server (NTRS)

    Urban, D. L.; Mulholland, G.; Yuan, Z. G.; Yang, J.; Cleary, T.

    2001-01-01

    'Smoke' is a flight definition investigation whose purpose is to characterize the smoke particulate from microgravity smoke sources to enable improved design of future space-craft smoke detectors. In the earliest missions (Mercury, Gemini and Apollo), the crew quarters were so cramped that it was considered reasonable that the astronauts would rapidly detect any fire. The Skylab module, however, included approximately 30 UV-sensing fire detectors. The Space Shuttle Orbiter has nine particle-ionization smoke detectors in the mid-deck and flight deck. The detectors for the US segments of the International Space Station (ISS) are laser-diode, forward-scattering, smoke detectors. Current plans for the ISS call for two detectors in the open area of the module, and detectors in racks that have cooling air-flow. Due to the complete absence of microgravity data, all three of these detector systems were designed based upon 1-g test data and experience. As planned mission durations and complexity increase and the volume of spacecraft increases, the need for and importance of effective, crew-independent, fire detection will grow significantly, necessitating more research into microgravity fire phenomena. In 1997 the Comparative Soot Diagnostics Experiment (CSD) flew in the Orbiter Middeck as a Glovebox payload. The CSD experiment was designed to produce small quantities of smoke from several sources to obtain particulate samples and to determine the response of the ISS and Orbiter smoke detectors to these sources. Marked differences in the performance of the detectors compared to their behavior in 1-g were observed. In extreme cases, the detector used in the orbiter was completely blind to easily visible smoke from sources that were readily detected in 1-g. It is hypothesized but as yet unverified that this performance difference was due to enhanced growth of liquid smoke droplets in low-g. These CSD results clearly demonstrate that spacecraft smoke detector design cannot be based on 1-g experience.

  3. Real-time edge-enhanced optical correlator

    NASA Astrophysics Data System (ADS)

    Shihabi, Mazen M.; Hinedi, Sami M.; Shah, Biren N.

    1992-08-01

    The performance of five symbol lock detectors are compared. They are the square-law detector with overlapping (SQOD) and non-overlapping (SQNOD) integrators, the absolute value detectors with overlapping and non-overlapping (AVNOD) integrators and the signal power estimator detector (SPED). The analysis considers various scenarios when the observation interval is much larger or equal to the symbol synchronizer loop bandwidth, which has not been considered in previous analyses. Also, the case of threshold setting in the absence of signal is considered. It is shown that the SQOD outperforms all others when the threshold is set in the presence of signal, independent of the relationship between loop bandwidth and observation period. On the other hand, the SPED outperforms all others when the threshold is set in the presence of noise only.

  4. Real-time edge-enhanced optical correlator

    NASA Technical Reports Server (NTRS)

    Shihabi, Mazen M. (Inventor); Hinedi, Sami M. (Inventor); Shah, Biren N. (Inventor)

    1992-01-01

    The performance of five symbol lock detectors are compared. They are the square-law detector with overlapping (SQOD) and non-overlapping (SQNOD) integrators, the absolute value detectors with overlapping and non-overlapping (AVNOD) integrators and the signal power estimator detector (SPED). The analysis considers various scenarios when the observation interval is much larger or equal to the symbol synchronizer loop bandwidth, which has not been considered in previous analyses. Also, the case of threshold setting in the absence of signal is considered. It is shown that the SQOD outperforms all others when the threshold is set in the presence of signal, independent of the relationship between loop bandwidth and observation period. On the other hand, the SPED outperforms all others when the threshold is set in the presence of noise only.

  5. Magnetospheric particle precipitation at Titan

    NASA Astrophysics Data System (ADS)

    Royer, Emilie; Esposito, Larry; Crary, Frank; Wahlund, Jan-Erik

    2017-04-01

    Although solar XUV radiation is known to be the main source of ionization in Titan's upper atmosphere around 1100 km of altitude, magnetospheric particle precipitation can also account for about 10% of the ionization process. Magnetospheric particle precipitation is expected to be the most intense on the nightside of the satelllite and when Titan's orbital position around Saturn is the closest to Noon Saturn Local Time (SLT). In addition, on several occasion throughout the Cassini mission, Titan has been observed while in the magnetosheath. We are reporting here Ultraviolet (UV) observations of Titan airglow enhancements correlated to these magnetospheric changing conditions occurring while the spacecraft, and thus Titan, are known to have crossed Saturn's magnetopause and have been exposed to the magnetosheath environnment. Using Cassini-Ultraviolet Imaging Spectrograph (UVIS) observations of Titan around 12PM SLT as our primary set of data, we present evidence of Titan's upper atmosphere response to a fluctuating magnetospheric environment. Pattern recognition software based on 2D UVIS detector images has been used to retrieve observations of interest, looking for airglow enhancement of a factor of 2. A 2D UVIS detector image, created for each UVIS observation of Titan, displays the spatial dimension of the UVIS slit on the x-axis and the time on the y-axis. In addition, data from the T32 flyby and from April 17, 2005 from in-situ Cassini instruments are used. Correlations with data from simultaneous observations of in-situ Cassini instruments (CAPS, RPWS and MIMI) has been possible on few occasions and events such as electron burst and reconnections can be associated with unusual behaviors of the Titan airglow. CAPS in-situ measurements acquired during the T32 flyby are consistent with an electron burst observed at the spacecraft as the cause of the UV emission. Moreover, on April 17, 2005 the UVIS observation displays feature similar to what could be aTitan aurora on the north pole, linked to a very fluctuating magnetospheric environment. CAPS data taken this same day indicates that the spacecraft crossed the magnetopause and provide evidence for possible reconnection events.

  6. Ultraviolet-B radiation modifies the quantitative and qualitative profile of flavonoids and amino acids in grape berries.

    PubMed

    Martínez-Lüscher, J; Torres, N; Hilbert, G; Richard, T; Sánchez-Díaz, M; Delrot, S; Aguirreolea, J; Pascual, I; Gomès, E

    2014-06-01

    Grapevine cv. Tempranillo fruit-bearing cuttings were exposed to supplemental ultraviolet-B (UV-B) radiation under controlled conditions, in order to study its effect on grape traits, ripening, amino acids and flavonoid profile. The plants were exposed to two doses of UV-B biologically effective (5.98 and 9.66kJm(-2)d(-1)), applied either from fruit set to ripeness or from the onset of veraison to ripeness. A 0kJm(-2)d(-1) treatment was included as a control. UV-B did not significantly modify grape berry size, but increased the relative mass of berry skin. Time to reach ripeness was not affected by UV-B, which may explain the lack of changes in technological maturity. The concentration of must extractable anthocyanins, colour density and skin flavonols were enhanced by UV-B, especially in plants exposed from fruit set. The quantitative and qualitative profile of grape skin flavonols were modified by UV-B radiation. Monosubstituted flavonols relative abundance increased proportionally to the accumulated UV-B doses. Furthermore, trisubstituted forms, which where predominant in non-exposed berries, were less abundant as UV-B exposure increased. Although total free amino acid content remained unaffected by the treatments, the increased levels of gamma-aminobutyric acid (GABA), as well as the decrease in threonine, isoleucine, methionine, serine and glycine, revealed a potential influence of UV-B on the GABA-mediated signalling and amino acid metabolism. UV-B had an overall positive impact on grape berry composition. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Miniaturized X-ray telescope for VZLUSAT-1 nanosatellite with Timepix detector

    NASA Astrophysics Data System (ADS)

    Baca, T.; Platkevic, M.; Jakubek, J.; Inneman, A.; Stehlikova, V.; Urban, M.; Nentvich, O.; Blazek, M.; McEntaffer, R.; Daniel, V.

    2016-10-01

    We present the application of a Timepix detector on the VZLUSAT-1 nanosatellite. Timepix is a compact pixel detector (256×256 square pixels, 55×55 μm each) sensitive to hard X-ray radiation. It is suitable for detecting extraterrestrial X-rays due to its low noise characteristics, which enables measuring without special cooling. This project aims to verify the practicality of the detector in conjunction with 1-D Lobster-Eye optics to observe celestial sources between 5 and 20 keV. A modified USB interface (developed by IEAP at CTU in Prague) is used for low-level control of the Timepix. An additional 8-bit Atmel microcontroller is dedicated for commanding the detector and to process the data onboard the satellite. We present software methods for onboard post-processing of captured images, which are suitable for implementation under the constraints of the low-powered embedded hardware. Several measuring modes are prepared for different scenarios including single picture exposure, solar UV-light triggered exposure, and long-term all-sky monitoring. The work has been done within Medipix2 collaboration. The satellite is planned for launch in April 2017 as a part of the QB50 project with an end of life expectancy in 2019.

  8. Quantum efficiency test set up performances for NIR detector characterization at ESTEC

    NASA Astrophysics Data System (ADS)

    Crouzet, P.-E.; Duvet, L.; De Wit, F.; Beaufort, T.; Blommaert, S.; Butler, B.; Van Duinkerken, G.; ter Haar, J.; Heijnen, J.; van der Luijt, K.; Smit, H.; Viale, T.

    2014-07-01

    The Payload Technology Validation Section (Future mission preparation Office) at ESTEC is in charge of specific mission oriented validation activities, for science and robotic exploration missions, aiming at reducing development risks in the implementation phase. These activities take place during the early mission phases or during the implementation itself. In this framework, a test set up to characterize the quantum efficiency of near infrared detectors has been developed. The first detector to be tested will an HAWAII-2RG detector with a 2.5μm cut off, it will be used as commissioning device in preparation to the tests of prototypes European detectors developed under ESA funding. The capability to compare on the same setup detectors from different manufacturers will be a unique asset for the future mission preparation office. This publication presents the performances of the quantum efficiency test bench to prepare measurements on the HAWAII-2RG detector. A SOFRADIR Saturn detector has been used as a preliminary test vehicle for the bench. A test set up with a lamp, chopper, monochromator, pinhole and off axis mirrors allows to create a spot of 1mm diameter between 700nm and 2.5μm.The shape of the beam has been measured to match the rms voltage read by the Merlin Lock -in amplifier and the amplitude of the incoming signal. The reference detectors have been inter-calibrated with an uncertainty up to 3 %. For the measurement with HAWAII-2RG detector, the existing cryostat [1] has been modified to adapt cold black baffling, a cold filter wheel and a sapphire window. An statistic uncertainty of +/-2.6% on the quantum efficiency on the detector under test measurement is expected.

  9. Designing the detection system for the CORUS project

    NASA Astrophysics Data System (ADS)

    Kalogirou, A.

    2013-05-01

    CORUS (Cosmic Rays in UK Schools) will be a network of muon detectors based in schools across the UK. Networks similar to CORUS already exist in other countries, such as the Netherlands and USA. The main aim of the project is to teach high schools students about cosmic rays and experimental physics as well as to motivate them to pursue studies in science. A set of muon detectors will be used for this purpose and the objective of this study is to complete the design of the detectors, construct them and test their capabilities and limitations. The most important component of the muon detector is the electronic card used to collect, analyse and output data. A DAQ card used by QuarkNet, a network of detectors in the USA, has been used in the design of the CORUS detectors. Some readily available photomultiplier tubes have also been used, along with an interface board which connects them to the DAQ board. In this study, I tested whether these two components work well together by conducting a series of experiments, intended to be performed by the students, with the nal detector set-up. The end result is that although a number of improvements is needed before the detectors serve their purpose, this particular set-up does not impose any limitations to the experiments that it is intended to be used for.

  10. Environmental Cues to Ultraviolet Radiation and Personal Sun Protection In Outdoor Winter Recreation

    PubMed Central

    Buller, David B.; Walkosz, Barbara J.; Scott, Michael D.; Maloy, Julie A.; Cutter, Gary R.; Dignan, Mark D.

    2012-01-01

    Objective The prevalence of ultraviolet radiation (UV) at North American ski resorts was predicted using temporal, seasonal, altitudinal, and meteorological factors and associated with a set of adult sun protection behaviors. Design UV observations and cross-sectional survey of adults on sun protection were collected. Setting Data were collected at 32 high-altitude ski areas located in Western North America in 2001–03. Participants The sample consisted of 3,937 adult skier or snowboarders. Main Outcome Measures Measurements of direct, reflected, and diffuse UV were performed at 487 measurement points using handheld meters and combined with self-reported and observed sun protection assessed for adults interviewed on chair lifts. Results The strongest predictors of UV were temporal proximity to noon, deviation from winter solstice, and clear skies. By contrast, altitude and latitude had more modest associations with UV and temperature had a small positive relationship with UV. Guest sun safety was inconsistently associated with UV: UV was positively related to adults wearing more sunscreen, reapplying it after two hours, and wearing protective eyewear but fewer adults exhibited many of the other sun protection behaviors, such as hats, protective clothing or lip balm, on days when UV was elevated. Guests took more sun safety precautions on clear-sky days but took steps to maintain body warmth on inclement days. Conclusions In future sun safety promotions, adults should be encouraged to wear sunscreen on cloudy days because UV is still high and conditions can change rapidly. They need reminders to rely more on season and time of day when judging UV and the need for sun safety. PMID:21079060

  11. 40 CFR 86.317-79 - Hydrocarbon analyzer specifications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... flame ionization detector (HFID) analyzer. (b) Option. A non-heated flame ionization detector (FID) that... temperature oven housing the detector and sample-handling components. It shall maintain temperature with 2 °C of the set point. The detector, oven, and sample-handling components within the oven shall be...

  12. 40 CFR 86.317-79 - Hydrocarbon analyzer specifications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... flame ionization detector (HFID) analyzer. (b) Option. A non-heated flame ionization detector (FID) that... temperature oven housing the detector and sample-handling components. It shall maintain temperature with 2 °C of the set point. The detector, oven, and sample-handling components within the oven shall be...

  13. 40 CFR 86.317-79 - Hydrocarbon analyzer specifications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... flame ionization detector (HFID) analyzer. (b) Option. A non-heated flame ionization detector (FID) that... temperature oven housing the detector and sample-handling components. It shall maintain temperature with 2 °C of the set point. The detector, oven, and sample-handling components within the oven shall be...

  14. 40 CFR 86.317-79 - Hydrocarbon analyzer specifications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... flame ionization detector (HFID) analyzer. (b) Option. A non-heated flame ionization detector (FID) that... temperature oven housing the detector and sample-handling components. It shall maintain temperature with 2 °C of the set point. The detector, oven, and sample-handling components within the oven shall be...

  15. Frequency-Locked Detector Threshold Setting Criteria Based on Mean-Time-To-Lose-Lock (MTLL) for GPS Receivers

    PubMed Central

    Zhao, Na; Qin, Honglei; Sun, Kewen; Ji, Yuanfa

    2017-01-01

    Frequency-locked detector (FLD) has been widely utilized in tracking loops of Global Positioning System (GPS) receivers to indicate their locking status. The relation between FLD and lock status has been seldom discussed. The traditional PLL experience is not suitable for FLL. In this paper, the threshold setting criteria for frequency-locked detector in the GPS receiver has been proposed by analyzing statistical characteristic of FLD output. The approximate probability distribution of frequency-locked detector is theoretically derived by using a statistical approach, which reveals the relationship between probabilities of frequency-locked detector and the carrier-to-noise ratio (C/N0) of the received GPS signal. The relationship among mean-time-to-lose-lock (MTLL), detection threshold and lock probability related to C/N0 can be further discovered by utilizing this probability. Therefore, a theoretical basis for threshold setting criteria in frequency locked loops for GPS receivers is provided based on mean-time-to-lose-lock analysis. PMID:29207546

  16. Frequency-Locked Detector Threshold Setting Criteria Based on Mean-Time-To-Lose-Lock (MTLL) for GPS Receivers.

    PubMed

    Jin, Tian; Yuan, Heliang; Zhao, Na; Qin, Honglei; Sun, Kewen; Ji, Yuanfa

    2017-12-04

    Frequency-locked detector (FLD) has been widely utilized in tracking loops of Global Positioning System (GPS) receivers to indicate their locking status. The relation between FLD and lock status has been seldom discussed. The traditional PLL experience is not suitable for FLL. In this paper, the threshold setting criteria for frequency-locked detector in the GPS receiver has been proposed by analyzing statistical characteristic of FLD output. The approximate probability distribution of frequency-locked detector is theoretically derived by using a statistical approach, which reveals the relationship between probabilities of frequency-locked detector and the carrier-to-noise ratio ( C / N ₀) of the received GPS signal. The relationship among mean-time-to-lose-lock (MTLL), detection threshold and lock probability related to C / N ₀ can be further discovered by utilizing this probability. Therefore, a theoretical basis for threshold setting criteria in frequency locked loops for GPS receivers is provided based on mean-time-to-lose-lock analysis.

  17. Dispositional study of opioids in mice pretreated with sympathomimetic agents.

    PubMed

    Dambisya, Y M; Chan, K; Wong, C L

    1992-08-01

    Brain and plasma levels of morphine and codeine were determined by an assay method involving solid-phase extraction and ion-pair reversed phase HPLC. Detection was by a variable wavelength UV-detector (for codeine) and an amperometric electro-chemical detector (for morphine) coupled in series. Ephedrine or phenylpropanolamine pretreatment did not interfere with the plasma disposition of morphine, evidenced by overlapping plasma concentration-time profiles. Brain opioid levels were equally unaffected by sympathomimetic pretreatment. The relative ratios of brain to plasma concentrations at the time corresponding to the respective peak anti-nociceptive activity for morphine and codeine revealed no significant differences. It is concluded that single doses of ephedrine and phenylpropanolamine do not affect the disposition of morphine and codeine in mice.

  18. Gear Tooth Wear Detection Algorithm

    NASA Technical Reports Server (NTRS)

    Delgado, Irebert R.

    2015-01-01

    Vibration-based condition indicators continue to be developed for Health Usage Monitoring of rotorcraft gearboxes. Testing performed at NASA Glenn Research Center have shown correlations between specific condition indicators and specific types of gear wear. To speed up the detection and analysis of gear teeth, an image detection program based on the Viola-Jones algorithm was trained to automatically detect spiral bevel gear wear pitting. The detector was tested using a training set of gear wear pictures and a blind set of gear wear pictures. The detector accuracy for the training set was 75 percent while the accuracy for the blind set was 15 percent. Further improvements on the accuracy of the detector are required but preliminary results have shown its ability to automatically detect gear tooth wear. The trained detector would be used to quickly evaluate a set of gear or pinion pictures for pits, spalls, or abrasive wear. The results could then be used to correlate with vibration or oil debris data. In general, the program could be retrained to detect features of interest from pictures of a component taken over a period of time.

  19. Characteristics and fate of natural organic matter during UV oxidation processes.

    PubMed

    Ahn, Yongtae; Lee, Doorae; Kwon, Minhwan; Choi, Il-Hwan; Nam, Seong-Nam; Kang, Joon-Wun

    2017-10-01

    Advanced oxidation processes (AOPs) are widely used in water treatments. During oxidation processes, natural organic matter (NOM) is modified and broken down into smaller compounds that affect the characteristics of the oxidized NOM by AOPs. In this study, NOM was characterized and monitored in the UV/hydrogen peroxide (H 2 O 2 ) and UV/persulfate (PS) processes using a liquid chromatography-organic carbon detector (LC-OCD) technique, and a combination of excitation-emission matrices (EEM) and parallel factor analysis (PARAFAC). The percentages of mineralization of NOM in the UV/H 2 O 2 and UV/PS processes were 20.5 and 83.3%, respectively, with a 10 mM oxidant dose and a contact time of 174 s (UV dose: approximately 30,000 mJ). Low-pressure, Hg UV lamp (254 nm) was applied in this experiment. The steady-state concentration of SO 4 - was 38-fold higher than that of OH at an oxidant dose of 10 mM. With para-chlorobenzoic acid (pCBA) as a radical probe compound, we experimentally determined the rate constants of Suwannee River NOM (SRNOM) with OH (k OH/NOM  = 3.3 × 10 8  M -1 s -1 ) and SO 4 - (k SO4-/NOM  = 4.55 × 10 6  M -1 s -1 ). The hydroxyl radical and sulfate radical showed different mineralization pathways of NOM, which have been verified by the use of LC-OCD and EEM/PARAFAC. Consequently, higher steady-state concentrations of SO 4 - , and different reaction preferences of OH and SO 4 - with the NOM constituent had an effect on the mineralization efficiency. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Comparison of ultraviolet absorbance and NO-chemiluminescence for ozone measurement in wildfire plumes at the Mount Bachelor Observatory

    NASA Astrophysics Data System (ADS)

    Gao, Honglian; Jaffe, Daniel A.

    2017-10-01

    The goal of this paper is to evaluate the accuracy of the commonly used ozone (O3) instrument (the ultraviolet (UV) photometer) against a Federal Reference Method (Nitric Oxide -chemiluminescence) for ozone measurement in wildfire smoke plumes. We carried out simultaneous ozone measurement with two UV O3 photometers and one nitric oxide-chemiluminescence (NO-CL) ozone detectors during wildfire season (Aug. 1-Sept. 30) in 2015 at the Mount Bachelor Observatory (MBO, 2763 m above mean sea level, Oregon, USA). The UV O3 shows good agreement and excellent correlation to NO-CL O3, with linear regression slopes close to unity and R2 of 0.92 for 1-h average data and R2 of 0.93 for O3 daily maximum 8-h average (MDA8). During this two-month period we identified 35 wildfire events. Ozone enhancements in those wildfire plumes measured by NO-CL O3 and UV O3 monitors also show good agreement and excellent linear correlation, with a slope and R2 of 1.03 and 0.86 for O3 enhancements (ΔO3) and 1.00 and 0.98 for carbon monoxide (CO)-normalized ozone enhancement ratios (ΔO3/ΔCO), respectively. Overall, the UV O3 was found to have a positive bias of 4.7 ± 2.8 ppbv compared to the NO-CL O3. The O3 bias between NO-CL O3 and UV O3 is independent of wildfire plume tracers such as CO, particulate matter (PM1), aerosol scattering, and ultrafine particles. The results demonstrate that the UV O3 absorbance method is reliable, even in highly concentrated wildfire plumes.

  1. New Linear Partitioning Models Based on Experimental Water: Supercritical CO 2 Partitioning Data of Selected Organic Compounds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burant, Aniela; Thompson, Christopher; Lowry, Gregory V.

    2016-05-17

    Partitioning coefficients of organic compounds between water and supercritical CO2 (sc-CO2) are necessary to assess the risk of migration of these chemicals from subsurface CO2 storage sites. Despite the large number of potential organic contaminants, the current data set of published water-sc-CO2 partitioning coefficients is very limited. Here, the partitioning coefficients of thiophene, pyrrole, and anisole were measured in situ over a range of temperatures and pressures using a novel pressurized batch reactor system with dual spectroscopic detectors: a near infrared spectrometer for measuring the organic analyte in the CO2 phase, and a UV detector for quantifying the analyte inmore » the aqueous phase. Our measured partitioning coefficients followed expected trends based on volatility and aqueous solubility. The partitioning coefficients and literature data were then used to update a published poly-parameter linear free energy relationship and to develop five new linear free energy relationships for predicting water-sc-CO2 partitioning coefficients. Four of the models targeted a single class of organic compounds. Unlike models that utilize Abraham solvation parameters, the new relationships use vapor pressure and aqueous solubility of the organic compound at 25 °C and CO2 density to predict partitioning coefficients over a range of temperature and pressure conditions. The compound class models provide better estimates of partitioning behavior for compounds in that class than the model built for the entire dataset.« less

  2. Laser-Induced Breakdown Spectroscopy Infrared Emission From Inorganic and Organic Substances

    DTIC Science & Technology

    2006-11-01

    using a liquid-nitrogen cooled indium antimonide (InSb) detector and the signal was recorded using a gated electronic circuit (boxcar averager). All...contaminants by analyzing the atomic spectral emission lines that result subsequent to plasmas generated by laser power. The ultraviolet-visible-near infrared...UV- Vis-NIR) spectral region exploited in conventional LIBS largely elucidates the elemental composition of the laser target by profiling these

  3. Suborbital Applications in Astronomy and Astrophysics

    NASA Technical Reports Server (NTRS)

    Unwin, Steve; Werner, Mike; Goldsmith, Paul

    2012-01-01

    Suborbital flights providing access to zero-g in a space environment - Demonstrating new technologies in a relevant environment. - Flight testing of individual elements of a constellation. - Raising the TRL of critical technologies for subsystems on future large missions High-altitude balloons (up to 10 kg payload) -Access to near-space for wavelengths not observable from the ground. -Raising the TRL of critical technologies for subsystems on future large missions. -UV Detector testing.

  4. Liquid Chromatographic Analysis of Hydraulic Fluids.

    DTIC Science & Technology

    1979-11-01

    chemical mixtures of a petroleum- or nonpetroleum-base stock component formulated with various additives which may be present in trace amounts or...absorb UV radiation near the monitoring wavelength may swamp the detector signal and therefore should be avoided in 1JV detection. The recorder trace of...Also, organic phosphites , thiophosphates, and sulfides are used to inhibit oxidative catalysis by metal ions. The oxidation inhibitor in 6083D-0 is BPC

  5. A Hybrid Readout Solution for GaN-Based Detectors Using CMOS Technology †

    PubMed Central

    Hancock, Bruce; Nikzad, Shouleh; Bell, L. Douglas; Kroep, Kees; Charbon, Edoardo

    2018-01-01

    Gallium nitride (GaN) and its alloys are becoming preferred materials for ultraviolet (UV) detectors due to their wide bandgap and tailorable out-of-band cutoff from 3.4 eV to 6.2 eV. GaN based avalanche photodiodes (APDs) are particularly suitable for their high photon sensitivity and quantum efficiency in the UV region and for their inherent insensitivity to visible wavelengths. Challenges exist however for practical utilization. With growing interests in such photodetectors, hybrid readout solutions are becoming prevalent with CMOS technology being adopted for its maturity, scalability, and reliability. In this paper, we describe our approach to combine GaN APDs with a CMOS readout circuit, comprising of a linear array of 1 × 8 capacitive transimpedance amplifiers (CTIAs), implemented in a 0.35 µm high voltage CMOS technology. Further, we present a simple, yet sustainable circuit technique to allow operation of APDs under high reverse biases, up to ≈80 V with verified measurement results. The readout offers a conversion gain of 0.43 µV/e−, obtaining avalanche gains up to 103. Several parameters of the CTIA are discussed followed by a perspective on possible hybridization, exploiting the advantages of a 3D-stacked technology. PMID:29401655

  6. Technology optimization techniques for multicomponent optical band-pass filter manufacturing

    NASA Astrophysics Data System (ADS)

    Baranov, Yuri P.; Gryaznov, Georgiy M.; Rodionov, Andrey Y.; Obrezkov, Andrey V.; Medvedev, Roman V.; Chivanov, Alexey N.

    2016-04-01

    Narrowband optical devices (like IR-sensing devices, celestial navigation systems, solar-blind UV-systems and many others) are one of the most fast-growing areas in optical manufacturing. However, signal strength in this type of applications is quite low and performance of devices depends on attenuation level of wavelengths out of operating range. Modern detectors (photodiodes, matrix detectors, photomultiplier tubes and others) usually do not have required selectivity or have higher sensitivity to background spectrum at worst. Manufacturing of a single component band-pass filter with high attenuation level of wavelength is resource-intensive task. Sometimes it's not possible to find solution for this problem using existing technologies. Different types of filters have technology variations of transmittance profile shape due to various production factors. At the same time there are multiple tasks with strict requirements for background spectrum attenuation in narrowband optical devices. For example, in solar-blind UV-system wavelengths above 290-300 nm must be attenuated by 180dB. In this paper techniques of multi-component optical band-pass filters assembly from multiple single elements with technology variations of transmittance profile shape for optimal signal-tonoise ratio (SNR) were proposed. Relationships between signal-to-noise ratio and different characteristics of transmittance profile shape were shown. Obtained practical results were in rather good agreement with our calculations.

  7. Comprehensive two-dimensional HPLC to study the interaction of multiple components in Rheum palmatum L. with HSA by coupling a silica-bonded HSA column to a silica monolithic ODS column.

    PubMed

    Hu, Lianghai; Li, Xin; Feng, Shun; Kong, Liang; Su, Xingye; Chen, Xueguo; Qin, Feng; Ye, Mingliang; Zou, Hanfa

    2006-04-01

    A mode of comprehensive 2-D LC was developed by coupling a silica-bonded HSA column to a silica monolithic ODS column. This system combined the affinity property of the HSA column and the high-speed separation ability of the monolithic ODS column. The affinity chromatography with HSA-immobilized stationary phase was applied to study the interaction of multiple components in traditional Chinese medicines (TCMs) with HSA according to their affinity to protein in the first dimension. Then the unresolved components retained on the HSA column were further separated on the silica monolithic ODS column in the second dimension. By hyphenating the 2-D separation system to diode array detector and MS detectors, the UV and molecular weight information of the separated compounds can also be obtained. The developed separation system was applied to analysis of the extract of Rheum palmatum L., a number of low-abundant components can be separated on a single peak from the HSA column after normalization of peak heights. Six compounds were preliminarily identified according to their UV and MS spectra. It showed that this system was very useful for biological fingerprinting analysis of the components in TCMs and natural products.

  8. Preliminary error budget analysis of the coronagraphic instrument metis for the solar orbiter ESA mission

    NASA Astrophysics Data System (ADS)

    Da Deppo, Vania; Poletto, Luca; Crescenzio, Giuseppe; Fineschi, Silvano; Antonucci, Ester; Naletto, Giampiero

    2017-11-01

    METIS, the Multi Element Telescope for Imaging and Spectroscopy, is the solar coronagraph foreseen for the ESA Solar Orbiter mission. METIS is conceived to image the solar corona from a near-Sun orbit in three different spectral bands: in the HeII EUV narrow band at 30.4 nm, in the HI UV narrow band at 121.6 nm, and in the polarized visible light band (590 - 650 nm). It also incorporates the capability of multi-slit spectroscopy of the corona in the UV/EUV range at different heliocentric heights. METIS is an externally occulted coronagraph which adopts an "inverted occulted" configuration. The Inverted external occulter (IEO) is a small circular aperture at the METIS entrance; the Sun-disk light is rejected by a spherical mirror M0 through the same aperture, while the coronal light is collected by two annular mirrors M1-M2 realizing a Gregorian telescope. To allocate the spectroscopic part, one portion of the M2 is covered by a grating (i.e. approximately 1/8 of the solar corona will not be imaged). This paper presents the error budget analysis for this new concept coronagraph configuration, which incorporates 3 different sub-channels: UV and EUV imaging sub-channel, in which the UV and EUV light paths have in common the detector and all of the optical elements but a filter, the polarimetric visible light sub-channel which, after the telescope optics, has a dedicated relay optics and a polarizing unit, and the spectroscopic sub-channel, which shares the filters and the detector with the UV-EUV imaging one, but includes a grating instead of the secondary mirror. The tolerance analysis of such an instrument is quite complex: in fact not only the optical performance for the 3 sub-channels has to be maintained simultaneously, but also the positions of M0 and of the occulters (IEO, internal occulter and Lyot stop), which guarantee the optimal disk light suppression, have to be taken into account as tolerancing parameters. In the aim of assuring the scientific requirements are optimally fulfilled for all the sub-channels, the preliminary results of manufacturing, alignment and stability tolerance analysis for the whole instrument will be described and discussed.

  9. Vertical mixing and methane photochemistry in the atmosphere of Uranus: Analysis of Voyager UVS occultation experiments

    NASA Technical Reports Server (NTRS)

    Bishop, James

    1991-01-01

    Extensive capabilities were developed in the analysis of ultraviolet spectrometer (UVS) absorptive lightcurves. The application of these capabilities to the Voyager UVS data sets from Uranus and Neptune has provided significant findings regarding the stratospheres of these planets. In particular, the direct comparison between photochemical models and UVS measurements accomplished by these efforts is unique, and it helps to guarantee that the information returned by the Voyager 2 spacecraft is being used to the fullest extent possible.

  10. New generation of Cherenkov counters

    NASA Astrophysics Data System (ADS)

    Giomataris, Y.; Charpak, G.; Peskov, V.; Sauli, F.

    1992-12-01

    Experimental results with a parallel plate avalanche chamber (PPAC) having a CsI photocathode and pad array readout are reported. High gains in excess of 10 5 have been obtained with He gas at atmospheric pressure and traces of CH 4 or CF 4 quencher. Such light gas mixtures extend the transparency for the Cherenkov light to the extreme UV region and allow detector operation with very low sensitivity to the ionization produced by minimum ionizing particles. A hadron blind detector (HBD) is discussed which exploits the broad photon energy bandwidth (≈ 10 eV) and the high Cherenkov threshold ( pπ = 15 GeV). This fast detector, since it has a good spatial resolution, can be used at the future Large Hadron Collider (LHC) or the Superconductivity Super Collider (SSC) either as an efficient electron tagger, rejecting hadrons faking electrons in the calorimeter, or as a pretracker giving fast electron and high-energy muon signature and momentum estimation. Other potential applications in the domain of Cherenkov light detection are also discussed.

  11. Advanced optical systems for ultra high energy cosmic rays detection

    NASA Astrophysics Data System (ADS)

    Gambicorti, L.; Pace, E.; Mazzinghi, P.

    2017-11-01

    A new advanced optical system is proposed and analysed in this work with the purpose to improve the photons collection efficiency of Multi-AnodePhotoMultipliers (MAPMT) detectors, which will be used to cover large focal surface of instruments dedicated to the Ultra High Energy Cosmic Rays (UHECRs, above 1019eV) and Ultra High Energy Neutrino (UHEN) detection. The employment of the advanced optical system allows to focus all photons inside the sensitive area of detectors and to improve the signal-to-noise ratios in the wavelength range of interest (300-400nm), thus coupling imaging and filtering capability. Filter is realised with a multilayer coating to reach high transparency in UV range and with a sharp cut-off outside. In this work the applications on different series of PMTs have been studied and results of simulations are shown. First prototypes have been realised. Finally, this paper proposes another class of adapters to be optically coupled on each pixel of MAPMT detector selected, consisting of non-imaging concentrators as Winston cones.

  12. Temperature dependence of alpha-induced scintillation in the 1,1,4,4-tetraphenyl-1,3-butadiene wavelength shifter

    NASA Astrophysics Data System (ADS)

    Veloce, L. M.; Kuźniak, M.; Di Stefano, P. C. F.; Noble, A. J.; Boulay, M. G.; Nadeau, P.; Pollmann, T.; Clark, M.; Piquemal, M.; Schreiner, K.

    2016-06-01

    Liquid noble based particle detectors often use the organic wavelength shifter 1,1,4,4-tetraphenyl-1,3-butadiene (TPB) which shifts UV scintillation light to the visible regime, facilitating its detection, but which also can scintillate on its own. Dark matter searches based on this type of detector commonly rely on pulse-shape discrimination (PSD) for background mitigation. Alpha-induced scintillation therefore represents a possible background source in dark matter searches. The timing characteristics of this scintillation determine whether this background can be mitigated through PSD. We have therefore characterized the pulse shape and light yield of alpha induced TPB scintillation at temperatures ranging from 300 K down to 4 K, with special attention given to liquid noble gas temperatures. We find that the pulse shapes and light yield depend strongly on temperature. In addition, the significant contribution of long time constants above ~50 K provides an avenue for discrimination between alpha decay events in TPB and nuclear-recoil events in noble liquid detectors.

  13. Development of a bioaerosol single particle detector (BIO IN) for the fast ice nucleus chamber FINCH

    NASA Astrophysics Data System (ADS)

    Bundke, U.; Reimann, B.; Nillius, B.; Jaenicke, R.; Bingemer, H.

    2009-10-01

    In this work we present the setup and first tests of our new BIO IN detector. This detector is designed to classify atmospheric ice nuclei (IN) for their biological content. Biological material is identified via its auto-fluorescence (intrinsic fluorescence) after irradiation with UV radiation. Ice nuclei are key substances for precipitation development via the Bergeron-Findeisen process. The level of scientific knowledge regarding origin and climatology (temporal and spatial distribution) of IN is very low. Some biological material is known to be active as IN even at relatively high temperatures of up to -2°C (e.g. pseudomonas syringae bacteria). These biological IN could have a strong influence on the formation of clouds and precipitation. We have designed the new BIO IN sensor to analyze the abundance of IN of biological origin. The instrument will be flown on one of the first missions of the new German research aircraft ''HALO'' (High Altitude and LOng Range).

  14. Analysis of biodiesel by high performance liquid chromatography using refractive index detector.

    PubMed

    Syed, Mahin Basha

    2017-01-01

    High-performance liquid chromatography (HPLC) was used for the determination of compounds occurring during the production of biodiesel from karanja and jatropha oil. Methanol was used for fast monitoring of conversion of karanja and jatropha oil triacylglycerols to fatty acid methyl esters and for quantitation of residual triacylglycerols (TGs), in the final biodiesel product. The individual sample compounds were identified using HPLC. Analysis of fatty acid methyl esters (FAMES) in blends of biodiesel by HPLC using a refractive index and a UV detector at 238 nm. Individual triacylglycerols, diacylglycerols, monoacylglycerols and methyl esters of oleic, linoleic and linolenic acids and free fatty acids were separated within 40 min. Hence HPLC was found to be best for the analysis of biodiesel. Analysis of biodiesel by HPLC using RID detector. Estimation of amount of FAMES in biodiesel. Individual triacylglycerols, diacylglycerols, monoacylglycerols and methyl esters of oleic, linoleic and linolenic acids and free fatty acids were separated within 40 min.

  15. Relative performance of selected detectors

    NASA Astrophysics Data System (ADS)

    Ranney, Kenneth I.; Khatri, Hiralal; Nguyen, Lam H.; Sichina, Jeffrey

    2000-08-01

    The quadratic polynomial detector (QPD) and the radial basis function (RBF) family of detectors -- including the Bayesian neural network (BNN) -- might well be considered workhorses within the field of automatic target detection (ATD). The QPD works reasonably well when the data is unimodal, and it also achieves the best possible performance if the underlying data follow a Gaussian distribution. The BNN, on the other hand, has been applied successfully in cases where the underlying data are assumed to follow a multimodal distribution. We compare the performance of a BNN detector and a QPD for various scenarios synthesized from a set of Gaussian probability density functions (pdfs). This data synthesis allows us to control parameters such as modality and correlation, which, in turn, enables us to create data sets that can probe the weaknesses of the detectors. We present results for different data scenarios and different detector architectures.

  16. High performance liquid chromatography time of flight electrospray ionization mass spectrometry for quantification of sesquiterpenes in Chrysanthemi indici Flos active extract

    PubMed Central

    Fu, Ling; Wang, Pan; Sun, Yiqun; Wang, Yangyang; Zhao, Jing; Ye, Yuting; Zhang, Yanbin; Bi, Yuefeng

    2015-01-01

    Background: Chrysanthemi indici Flos, a traditional herbal medicine is used to clearing heat–toxicity, removing the liver fire, and improving eyesight. In our preliminary work, an active extract of CTC in C. An indici Flos with anti-hepatitis B virus and liver protective activity was found by HepG2.2.1.5 test and experiment of protein synthesis in mice's injured liver. In this work, we aimed to study the active faction CTC further by qualitative and quantitative analysis method. Materials and Methods: High performance liquid chromatography time of flight electrospray ionization mass spectrometry (HPLC TOF ESI-MS) analysis method of the CTC was established. Cumambrin A and angeloylcumambrin B in CTC were analyzed by high performance liquid chromatography-ultraviolet-evaporative light scattering detector (HPLC-UV-ELSD) analysis methods. A binary gradient elution program was conducted for chromatographic separation with acetonitrile (A) and ultrapure water (B) as follows: 0–10 min, 42–46% A; 10–20 min, 46–55% A; 20–25 min, 55–60% A; and 25–35 min, 60–75% A. The column temperature and UV wavelength were set at 30°C and 205 nm. Result: Ten constituents including (3R, 5R, 6S, 7S, 10R)-7-(2-hydroxy-2-propyl)-10-methyl-4-methyleneperhy, dronaphthal-ene-3, 5, 6-triol acetone solvate; (+)-edusmance-4, (14)-ene-11, 13-diol; linarin; luteolin; apigenin; tricin; 5, 3’,4’- trimethyl-6,7-dimethoxy flavones; cumambrin A; acacetin; and angeloylcumambrin B in CTC were identified by HPLC TOF ESI-MS. The contents of sesquiterpenes in CTC were decreased by storing years. Conclusions: The results showed that both UV and ELSD methods were feasible, accurate, and the determination results were in good consistency. The contents of two sesquiterpenes decreased with storing years. Two sesquiterpenes could be used as quality control for C. indici flos CTC. PMID:26600718

  17. A metal-semiconductor-metal detector based on ZnO nanowires grown on a graphene layer.

    PubMed

    Xu, Qiang; Cheng, Qijin; Zhong, Jinxiang; Cai, Weiwei; Zhang, Zifeng; Wu, Zhengyun; Zhang, Fengyan

    2014-02-07

    High quality ZnO nanowires (NWs) were grown on a graphene layer by a hydrothermal method. The ZnO NWs revealed higher uniform surface morphology and better structural properties than ZnO NWs grown on SiO2/Si substrate. A low dark current metal-semiconductor-metal photodetector based on ZnO NWs with Au Schottky contact has also been fabricated. The photodetector displays a low dark current of 1.53 nA at 1 V bias and a large UV-to-visible rejection ratio (up to four orders), which are significantly improved compared to conventional ZnO NW photodetectors. The improvement in UV detection performance is attributed to the existence of a surface plasmon at the interface of the ZnO and the graphene.

  18. Hexagonal boron nitride neutron detectors with high detection efficiencies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maity, A.; Grenadier, S. J.; Li, J.

    Here, neutron detectors fabricated from 10B enriched hexagonal boron nitride (h- 10BN or h-BN) epilayers have demonstrated the highest thermal neutron detection efficiency among solid-state neutron detectors to date at about 53%. In this work, photoconductive-like vertical detectors with a detection area of 1 × 1 mm 2 were fabricated from 50 μm thick free-standing h-BN epilayers using Ni/Au and Ti/Al bilayers as ohmic contacts. Leakage currents, mobility-lifetime (μτ) products under UV photoexcitation, and neutron detection efficiencies have been measured for a total of 16 different device configurations. The results have unambiguously identified that detectors incorporating the Ni/Au bilayer onmore » both surfaces as ohmic contacts and using the negatively biased top surface for neutron irradiation are the most desired device configurations. It was noted that high growth temperatures of h- 10BN epilayers on sapphire substrates tend to yield a higher concentration of oxygen impurities near the bottom surface, leading to a better device performance by the chosen top surface for irradiation than by the bottom. Preferential scattering of oxygen donors tends to reduce the mobility of holes more than that of electrons, making the biasing scheme with the ability of rapidly extracting holes at the irradiated surface while leaving the electrons to travel a large average distance inside the detector at a preferred choice. When measured against a calibrated 6LiF filled micro-structured semiconductor neutron detector, it was shown that the optimized configuration has pushed the detection efficiency of h-BN neutron detectors to 58%. These detailed studies also provided a better understanding of growth-mediated impurities in h-BN epilayers and their effects on the charge collection and neutron detection efficiencies.« less

  19. Hexagonal boron nitride neutron detectors with high detection efficiencies

    NASA Astrophysics Data System (ADS)

    Maity, A.; Grenadier, S. J.; Li, J.; Lin, J. Y.; Jiang, H. X.

    2018-01-01

    Neutron detectors fabricated from 10B enriched hexagonal boron nitride (h-10BN or h-BN) epilayers have demonstrated the highest thermal neutron detection efficiency among solid-state neutron detectors to date at about 53%. In this work, photoconductive-like vertical detectors with a detection area of 1 × 1 mm2 were fabricated from 50 μm thick free-standing h-BN epilayers using Ni/Au and Ti/Al bilayers as ohmic contacts. Leakage currents, mobility-lifetime (μτ) products under UV photoexcitation, and neutron detection efficiencies have been measured for a total of 16 different device configurations. The results have unambiguously identified that detectors incorporating the Ni/Au bilayer on both surfaces as ohmic contacts and using the negatively biased top surface for neutron irradiation are the most desired device configurations. It was noted that high growth temperatures of h-10BN epilayers on sapphire substrates tend to yield a higher concentration of oxygen impurities near the bottom surface, leading to a better device performance by the chosen top surface for irradiation than by the bottom. Preferential scattering of oxygen donors tends to reduce the mobility of holes more than that of electrons, making the biasing scheme with the ability of rapidly extracting holes at the irradiated surface while leaving the electrons to travel a large average distance inside the detector at a preferred choice. When measured against a calibrated 6LiF filled micro-structured semiconductor neutron detector, it was shown that the optimized configuration has pushed the detection efficiency of h-BN neutron detectors to 58%. These detailed studies also provided a better understanding of growth-mediated impurities in h-BN epilayers and their effects on the charge collection and neutron detection efficiencies.

  20. Hexagonal boron nitride neutron detectors with high detection efficiencies

    DOE PAGES

    Maity, A.; Grenadier, S. J.; Li, J.; ...

    2018-01-23

    Here, neutron detectors fabricated from 10B enriched hexagonal boron nitride (h- 10BN or h-BN) epilayers have demonstrated the highest thermal neutron detection efficiency among solid-state neutron detectors to date at about 53%. In this work, photoconductive-like vertical detectors with a detection area of 1 × 1 mm 2 were fabricated from 50 μm thick free-standing h-BN epilayers using Ni/Au and Ti/Al bilayers as ohmic contacts. Leakage currents, mobility-lifetime (μτ) products under UV photoexcitation, and neutron detection efficiencies have been measured for a total of 16 different device configurations. The results have unambiguously identified that detectors incorporating the Ni/Au bilayer onmore » both surfaces as ohmic contacts and using the negatively biased top surface for neutron irradiation are the most desired device configurations. It was noted that high growth temperatures of h- 10BN epilayers on sapphire substrates tend to yield a higher concentration of oxygen impurities near the bottom surface, leading to a better device performance by the chosen top surface for irradiation than by the bottom. Preferential scattering of oxygen donors tends to reduce the mobility of holes more than that of electrons, making the biasing scheme with the ability of rapidly extracting holes at the irradiated surface while leaving the electrons to travel a large average distance inside the detector at a preferred choice. When measured against a calibrated 6LiF filled micro-structured semiconductor neutron detector, it was shown that the optimized configuration has pushed the detection efficiency of h-BN neutron detectors to 58%. These detailed studies also provided a better understanding of growth-mediated impurities in h-BN epilayers and their effects on the charge collection and neutron detection efficiencies.« less

  1. ShellFit: Reconstruction in the MiniCLEAN Detector

    NASA Astrophysics Data System (ADS)

    Seibert, Stanley

    2010-02-01

    The MiniCLEAN dark matter experiment is an ultra-low background liquid cryogen detector with a fiducial volume of approximately 150 kg. Dark matter candidate events produce ultraviolet scintillation light in argon at 128 nm and in neon at 80 nm. In order to detect this scintillation light, the target volume is enclosed by acrylic plates forming a spherical shell upon which an organic fluor, tetraphenyl butadiene (TPB), has been applied. TPB absorbs UV light and reemits visible light isotropically which can be detected by photomultiplier tubes. Two significant sources of background events in MiniCLEAN are decays of radon daughters embedded in the acrylic surface and external sources of neutrons, such as the photomultiplier tubes themselves. Both of these backgrounds can be mitigated by reconstructing the origin of the scintillation light and cutting events beyond a particular radius. The scrambling of photon trajectories at the TPB surface makes this task very challenging. The ``ShellFit'' algorithm for reconstructing event position and energy in a detector with a spherical wavelength-shifting shell will be described. The performance of ShellFit will be demonstrated using Monte Carlo simulation of several event types in the MiniCLEAN detector. )

  2. WFC3 UVIS Detector Performance

    NASA Astrophysics Data System (ADS)

    Gunning, Heather C.; Baggett, Sylvia M.; Gosmeyer, Catherine; Bourque, Matthew; MacKenty, John W.; Anderson, Jay; WFC3 Team

    2015-01-01

    The Wide Field Camera 3 (WFC3) is a fourth-generation imaging instrument installed on the Hubble Space Telescope (HST) during Servicing Mission 4 (SM4) in May 2000. WFC3 has two observational channels, UV/visible (UVIS) and infrared (IR); both have been performing well on-orbit. Since installation, the WFC3 team has been diligent in monitoring the performance of both detectors. The UVIS channel consists of two e2v, backside illuminated, 2Kx4K CCDs arranged in a 2x1 mosaic. We present results from some of the monitoring programs used to check various aspects of the UVIS detector. We discuss the growth trend of hot pixels and the efficacy of regular anneals in controlling the hot pixel population. We detail a pixel population with lowered-sensitivity that evolves during the time between anneals, and is largely reset by each anneal procedure. We discuss the stability of the post-flash LED lamp, used and recommended for CTE mitigation in observations with less than 12 e-/pixel backgrounds. Finally, we summarize long-term photometric trends of the UVIS detector, as well as the absolute gain measurement, used as a proxy for the on-orbit evolution of the UVIS channel.

  3. Demonstration of the First 4H-SiC EUV Detector with Large Detection Area

    NASA Technical Reports Server (NTRS)

    Xin, Xiaobin; Yan, Feng; Koeth, Timothy W.; Hu, Jun; Zhao, Jian H.

    2005-01-01

    Ultraviolet (UV) and Extreme Ultraviolet (EUV) detectors are very attractive in astronomy, photolithography and biochemical applications. For EUV applications, most of the semiconductor detectors based on PN or PIN structures suffer from the very short penetration depth. Most of the carries are absorbed at the surface and recombined there due to the high surface recombination before reach the depletion region, resulting very low quantum efficiency. On the other hand, for Schottky structures, the active region starts from the surface and carriers generated from the surface can be efficiently collected. 4H-Sic has a bandgap of 3.26eV and is immune to visible light background noise. Also, 4H-Sic detectors usually have very good radiation hardness and very low noise, which is very important for space applications where the signal is very weak. The E W photodiodes presented in this paper are based on Schottky structures. Platinum (Pt) and Nickel (Ni) are selected as the Schottky contact metals, which have the highest electron work functions (5.65eV and 5.15eV, respectively) among all the known metals on 4H-Sic.

  4. The Ultraviolet Sky: final catalogs of unique UV sources from GALEX, and characterization of the UV-emitting sources across the sky, and of the Milky Way extinction

    NASA Astrophysics Data System (ADS)

    Bianchi, Luciana; Conti, A.; Shiao, B.; Keller, G. R.; Thilker, D. A.

    2014-01-01

    The legacy of the Galaxy Evolution Explorer (GALEX), which imaged the sky at Ultraviolet (UV) wavelengths for about 9 years, is its unprecedented database with more than 200 million source measurements in far-UV (FUV) and near-UV (NUV), as well as wide-field imaging of extended objects. GALEX's data, the first substantial sky surveys at UV wavelengths, offer an unprecedented view of the sky and a unique opportunity for an unbiased characterization of several classes of astrophysical objects, such as hot stars, QSOs at red-shift about 1, UV-peculiar QSOs, star-forming galaxies, among others. Bianchi et al. (2013, J. Adv. Space Res. (2013), DOI: http://dx.doi.org/10.1016/j.asr.2013.07.045) have constructed final catalogs of UV sources, with homogeneous quality, eliminating duplicate measurements of the same source ('unique' source catalogs), and excluding rim artifacts and bad photometry. The catalogs are constructed improving on the recipe of Bianchi et al. 2011 (MNRAS, 411, 2770, which presented the earlier version of these catalogs) and include all data for the major surveys, AIS and MIS. Considering the fields where both FUV and NUV detectors were exposed, the catalogs contain about 71 and 16.6 million unique sources respectively. We show several maps illustrating the content of UV sources across the sky, globally, and separately for bright/faint, hot, stellar/extragalactic objects. We matched the UV-source catalogs with optical-IR data from the SDSS, GSC2, 2MASS surveys. We are also in the process of matching the catalogs with preliminary PanSTARRS1 (PS1) 3pi survey photometry which already provides twice the sky coverage of SDSS, at slightly fainter magnitude limits. The sources' SED from FUV to optical wavelengths enables classification, derivation of the object physical parameters, and ultimately also a map of the Milky Way extinction. The catalogs will be available on MAST, Vizier (where the previous version already is), and in reduced form (for agile downloading), with related tools, from the author web site " http://dolomiti.pha.jhu.edu/uvsky "

  5. X-ray spectrometer with a low-cost SiC photodiode

    NASA Astrophysics Data System (ADS)

    Zhao, S.; Lioliou, G.; Barnett, A. M.

    2018-04-01

    A low-cost Commercial-Off-The-Shelf (COTS) 4H-SiC 0.06 mm2 UV p-n photodiode was coupled to a low-noise charge-sensitive preamplifier and used as photon counting X-ray spectrometer. The photodiode/spectrometer was investigated at X-ray energies from 4.95 keV to 21.17 keV: a Mo cathode X-ray tube was used to fluoresce eight high-purity metal foils to produce characteristic X-ray emission lines which were used to characterise the instrument. The energy resolution (full width at half maximum, FWHM) of the spectrometer was found to be 1.6 keV to 1.8 keV, across the energy range. The energy linearity of the detector/spectrometer (i.e. the detector's charge output per photon as a function of incident photon energy across the 4.95 keV to 21.17 keV energy range), as well as the count rate linearity of the detector/spectrometer (i.e. number of detected photons as a function of photon fluence at a specific energy) were investigated. The energy linearity of the detector/spectrometer was linear with an error < ± 0.7 %; the count rate linearity of the detector/spectrometer was linear with an error < ± 2 %. The use of COTS SiC photodiodes as detectors for X-ray spectrometers is attractive for nanosatellite/CubeSat applications (including solar flare monitoring), and for cost sensitive industrial uses.

  6. Enhanced UV light detection using a p-terphenyl wavelength shifter

    NASA Astrophysics Data System (ADS)

    Joosten, S.; Kaczanowicz, E.; Ungaro, M.; Rehfuss, M.; Johnston, K.; Meziani, Z.-E.

    2017-10-01

    UV-glass photomultiplier tubes (PMTs) have poor photon detection efficiency for wavelengths below 300 nm due to the opaqueness of the window material. Costly quartz PMTs could be used to enhance the efficiency below 300 nm. A less expensive solution that dramatically improves this efficiency is the application of a thin film of a p-terphenyl (PT) wavelength shifter on UV-glass PMTs. This improvement was quantified for Photonis XP4500B PMTs for wavelengths between 200 nm and 400 nm. The gain factor ranges up to 5 . 4 ± 0 . 5 at a wavelength of 215 nm, with a material load of 110 ± 10 μg /cm2 (894 nm). The wavelength shifter was found to be fully transparent for wavelengths greater than 300 nm. The resulting gain in detection efficiency, when used in a typical C̆erenkov counter, was estimated to be of the order of 40%. Consistent coating quality was assured by a rapid gain testing procedure using narrow-band UV LEDs. Based on these results, 200 Photonis XP4500B PMTs were treated with PT for the upgraded low-threshold C̆erenkov counter (LTCC) to be used in the CEBAF Large Acceptance Spectrometer upgraded detector (CLAS12) at the Thomas Jefferson National Accelerator Facility.

  7. Comparison of solar hard X-ray and UV line and continuum bursts with high time resolution

    NASA Technical Reports Server (NTRS)

    Orwig, L. E.; Woodgate, B. E.

    1986-01-01

    A comparison of data sets from the UV Spectrometer and Polarimeter and Hard X-ray Burst Spectrometer instruments on SMM has established the close relationship of the impulsive phase hard X-ray and UV continuum and OV line emissions, lending support to the notion that they have a similar origin low in the solar atmosphere. These results severely constrain models that attempt to explain impulsive phase hard X-rays and UV emission; alternative processes of impulsive-phase UV continuum production should accordingly be considered. Attention is given to an electron beam 'hole boring' mechanism and a photoionization radiation transport mechanism.

  8. Incorporation of multiple cloud layers for ultraviolet radiation modeling studies

    NASA Technical Reports Server (NTRS)

    Charache, Darryl H.; Abreu, Vincent J.; Kuhn, William R.; Skinner, Wilbert R.

    1994-01-01

    Cloud data sets compiled from surface observations were used to develop an algorithm for incorporating multiple cloud layers into a multiple-scattering radiative transfer model. Aerosol extinction and ozone data sets were also incorporated to estimate the seasonally averaged ultraviolet (UV) flux reaching the surface of the Earth in the Detroit, Michigan, region for the years 1979-1991, corresponding to Total Ozone Mapping Spectrometer (TOMS) version 6 ozone observations. The calculated UV spectrum was convolved with an erythema action spectrum to estimate the effective biological exposure for erythema. Calculations show that decreasing the total column density of ozone by 1% leads to an increase in erythemal exposure by approximately 1.1-1.3%, in good agreement with previous studies. A comparison of the UV radiation budget at the surface between a single cloud layer method and a multiple cloud layer method presented here is discussed, along with limitations of each technique. With improved parameterization of cloud properties, and as knowledge of biological effects of UV exposure increase, inclusion of multiple cloud layers may be important in accurately determining the biologically effective UV budget at the surface of the Earth.

  9. Enabling High Performance Instruments for Astronomy and Space Exploration and ALD

    NASA Technical Reports Server (NTRS)

    Greer, Frank; Lee, M. C.; Hoenk, M. E.; Jones, T. J.; Jacquot, B. C.; Dickie, M.; Monacos, S.; Nikzad, S.; Day, P.; Leduc, R.; hide

    2012-01-01

    Benefits of ALD for NASA instruments and applications: a) Ultrathin, highly conformal, and uniform films over arbitrarily large surface area. b). High quality films (density, roughness, conductivity, etc.) . Angstrom level control of stoichiometry, interfaces, and surface properties: 1) Multilayer nanolaminates/nanocomposites. 2) Low temperature surface engineering. Flight applications enabled by ALD: a) Anti-reflective coatings/Mirrors/Filters/Optics for UV/Vis/NIR Detectors. b) Superconducting Films for Submillimeter Astronomy.

  10. Renewable Bio-Solar Hydrogen Production From Robust Oxygenic Phototrophs: The Second Generation

    DTIC Science & Technology

    2014-07-14

    FeFe]-hydrogenases exposed to controlled amounts of oxygen. The results of UV/Vis, EPR, and IR spectroscopic characterization indicate the... paper : SD MCP. Isolated the strain: SB BB. References 1. Vignais PM, Billoud B (2007) Occurrence, classification, and biological function of...Scientific) equipped with a Globar IR source, a CaF2 beam splitter, and a liquid- nitrogen-cooled mercury cadmium telluride (MCT) detector.27 All of

  11. Determination of the Antibiotic Oxytetracycline in Commercial Milk by Solid-Phase Extraction: A High-Performance Liquid Chromatography (HPLC) Experiment for Quantitative Instrumental Analysis

    ERIC Educational Resources Information Center

    Mei-Ratliff, Yuan

    2012-01-01

    Trace levels of oxytetracylcine spiked into commercial milk samples are extracted, cleaned up, and preconcentrated using a C[subscript 18] solid-phase extraction column. The extract is then analyzed by a high-performance liquid chromatography (HPLC) instrument equipped with a UV detector and a C[subscript 18] column (150 mm x 4.6 mm x 3.5 [mu]m).…

  12. Inactivation of Microbiological Contaminants in Drinking Water by Ultraviolet Light Technology: NeoTech Aqua Solutions, Inc.; Ultraviolet Water Treatment System, NeoTech D438™ (Report and VS)

    EPA Science Inventory

    The NeoTech Aqua Solutions, Inc. D438™ UV Water Treatment System was tested to validate the UV dose delivered by the system using biodosimetry and a set line approach. The set line for 40 mJ/cm2 measured Reduction Equivalent Dose (RED) was based on validation testing at three (3)...

  13. Field comparison of several commercially available radon detectors.

    PubMed Central

    Field, R W; Kross, B C

    1990-01-01

    To determine the accuracy and precision of commercially available radon detectors in a field setting, 15 detectors from six companies were exposed to radon and compared to a reference radon level. The detectors from companies that had already passed National Radon Measurement Proficiency Program testing had better precision and accuracy than those detectors awaiting proficiency testing. Charcoal adsorption detectors and diffusion barrier charcoal adsorption detectors performed very well, and the latter detectors displayed excellent time averaging ability. Alternatively, charcoal liquid scintillation detectors exhibited acceptable accuracy but poor precision, and bare alpha registration detectors showed both poor accuracy and precision. The mean radon level reported by the bare alpha registration detectors was 68 percent lower than the radon reference level. PMID:2368851

  14. Searches for heavy long-lived sleptons and R-hadrons with the ATLAS detector in pp collisions at s = 7   TeV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aad, G.; Abajyan, T.; Abbott, B.

    2013-03-01

    A search for long-lived particles is performed using a data sample of 4.7 fb -1 from proton–proton collisions at a centre-of-mass energy √s=7 TeV collected by the ATLAS detector at the LHC. No excess is observed above the estimated background and lower limits, at 95% confidence level, are set on the mass of the long-lived particles in different scenarios, based on their possible interactions in the inner detector, the calorimeters and the muon spectrometer. Long-lived staus in gauge-mediated SUSY-breaking models are excluded up to a mass of 300 GeV for tan β= 5-20. Directly produced long-lived sleptons are excluded upmore » to a mass of 278 GeV. R-hadrons, composites of gluino (stop, sbottom) and light quarks, are excluded up to a mass of 985 GeV (683 GeV, 612 GeV) when using a generic interaction model. Additionally two sets of limits on R-hadrons are obtained that are less sensitive to the interaction model for R-hadrons. One set of limits is obtained using only the inner detector and calorimeter observables, and a second set of limits is obtained based on the inner detector alone.« less

  15. Optimising in situ gamma measurements to identify the presence of radioactive particles in land areas.

    PubMed

    Rostron, Peter D; Heathcote, John A; Ramsey, Michael H

    2014-12-01

    High-coverage in situ surveys with gamma detectors are the best means of identifying small hotspots of activity, such as radioactive particles, in land areas. Scanning surveys can produce rapid results, but the probabilities of obtaining false positive or false negative errors are often unknown, and they may not satisfy other criteria such as estimation of mass activity concentrations. An alternative is to use portable gamma-detectors that are set up at a series of locations in a systematic sampling pattern, where any positive measurements are subsequently followed up in order to determine the exact location, extent and nature of the target source. The preliminary survey is typically designed using settings of detector height, measurement spacing and counting time that are based on convenience, rather than using settings that have been calculated to meet requirements. This paper introduces the basis of a repeatable method of setting these parameters at the outset of a survey, for pre-defined probabilities of false positive and false negative errors in locating spatially small radioactive particles in land areas. It is shown that an un-collimated detector is more effective than a collimated detector that might typically be used in the field. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  16. Hand-portable liquid chromatographic instrumentation.

    PubMed

    Sharma, Sonika; Tolley, Luke T; Tolley, H Dennis; Plistil, Alex; Stearns, Stanley D; Lee, Milton L

    2015-11-20

    Over the last four decades, liquid chromatography (LC) has experienced an evolution to smaller columns and particles, new stationary phases and low flow rate instrumentation. However, the development of person-portable LC has not followed, mainly due to difficulties encountered in miniaturizing pumps and detectors, and in reducing solvent consumption. The recent introduction of small, non-splitting pumping systems and UV-absorption detectors for use with capillary columns has finally provided miniaturized instrumentation suitable for high-performance hand-portable LC. Fully integrated microfabricated LC still remains a significant challenge. Ion chromatography (IC) has been successfully miniaturized and applied for field analysis; however, applications are mostly limited to inorganic and small organic ions. This review covers advancements that make possible more rapid expansion of portable forms of LC and IC. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. UTEX: integrated ultraviolet and x-ray astronomy facility on spacelab, phase a study. Volume 1: executive summary. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1976-07-01

    A multipurpose UV telescope coupled with an X-ray detector to be flown on Spacelab is described. The instrument is capable of operating in the following basic modes: imagery over a field of 1 deg 65 with a focal ratio of f/2, time resolved rapid photometry correlated with X-ray observations, spectroscopy of both point-like and extended sources, and objective grating spectroscopy. The optical layout is a 60 cm f/8 Ritchey-Chretien configuration with f/2.4 Schmidt class focal reducer. The X-ray detector is a four layer multiwire proportional counter. The engineering effort was oriented to identify possible system configurations satisfying both scientific requirementsmore » and Spacelab interfaces and constraints.« less

  18. Determination of vitamin E and carotenoid pigments by high performance liquid chromatography in shell of Chionoecetes opilio.

    PubMed

    Vilasoa-Martínez, María; Calaza-Ramos, Carina; López-Hernández, Julia; Lage-Yusty, María Asunción; Losada, Perfecto Paseiro; Rodríguez-Bernaldo de Quirós, Ana

    2008-06-09

    This study reports the optimization of a method for the determination of vitamin E and carotenoids in shells of Chionoecetes opilio samples by online HPLC coupled with UV-vis and fluorescence detectors. The carotenoids were determined with diode-array detector (lambda 450 nm) and vitamin E with fluorescence detection (lambda(ex) 288, lambda(em) 331 nm). Two extractions methods were compared, saponification followed by an extraction step and a simple extraction with acetone. The last one was selected because allows to determine all compounds. Linearity, precisions and recoveries achieved for all compounds were satisfactory. Mean concentrations (mg per 100 g dry weight) were; 23.3 for vitamin E, 9.49 for astaxanthin and 0.2 mg for beta-carotene.

  19. Using Wave and Energetic Particle Observation on Juno to Investigate Low Altitude Magnetospheric Process on Jupiter.

    NASA Astrophysics Data System (ADS)

    Thorne, R. M.; Li, W.; Ma, Q.; Zhang, X.

    2017-12-01

    The Juno spacecraft has now made several passes across the polar regions and low altitude equatorial region in the Jovian upper atmosphere. Here we report on a recent analysis of unique Landau resonant wave-particle interactions between low frequency waves and energetic particles which leads to characteristic butterfly distributions in the sub-auroral upper atmosphere of Jupiter. We also report on the characteristics of diffuse auroral precipitation observed by the JEDI and JADE energetic particle detectors equatorward of the main auroral oval, and relate this to remote sensing of the Jovian aurora by the UVS instrument on Juno. The loss cone distributions, measured by the JEDI particle detector, have also been used to investigate the spatial distribution of low altitude anomalies in the Jovian magnetic field.

  20. Evaluating the impact of LED bulb development on the economic viability of ultraviolet technology for disinfection.

    PubMed

    Ibrahim, Mohamed A S; MacAdam, Jitka; Autin, Olivier; Jefferson, Bruce

    2014-01-01

    Ultraviolet (UV) technologies have been very successful in disinfection applications due to their ability to inactivate microorganisms without producing harmful disinfection by-products. However, there have been a number of concerns associated with the use of conventional UV systems such as hazardous mercury content, high capital investment and reduced electrical efficiency. These concerns have set limitations for the use of UV processes. The study evaluates the development of light emitting diode (LED) technology as an alternative UV source over the last 5 years, analyses the projections provided by the researchers and UV LED manufacturers and presents the information in a cost model with the aim to predict the timeline at which UV LED will compete with traditional UV low pressure high output technology in the commercial market at full-scale residential and industrial disinfection applications.

  1. A new way of searching for transients: the ADWO method and its results

    NASA Astrophysics Data System (ADS)

    Bagoly, Z.; Szecsi, D.; Ripa, J.; Racz, I. I.; Csabai, I.; Dobos, L.; Horvath, I.; Balazs, L. G.; Toth, L. V.

    2017-12-01

    With the detection of gravitational wave emissions from from merging compact objects, it is now more important than ever to effectively mine the data-set of gamma-satellites for non-triggered, short-duration transients. Hence we developed a new method called the Automatized Detector Weight Optimization (ADWO), applicable for space-borne detectors such as Fermi's GBM and RHESSI's Ge detectors. Provided that the trigger time of an astrophysical event is well known (as in the case of a gravitational wave detection) but the detector response matrix is uncertain, ADWO combines the data of all detectors and energy channels to provide the best signal-to-noise ratio. We used ADWO to successfully identify any potential electromagnetic counterpart of gravitational wave events, as well as to detect previously un-triggered short-duration GRBs in the data-sets.

  2. Quality evaluation of Yin Chen Hao Tang extract based on fingerprint chromatogram and simultaneous determination of five bioactive constituents.

    PubMed

    Wang, Xijun; Lv, Haitao; Sun, Hui; Jiang, Xingang; Wu, Zeming; Sun, Wenjun; Wang, Ping; Liu, Lian; Bi, Kaishun

    2008-01-01

    A completely validated method based on HPLC coupled with photodiode array detector (HPLC-UV) was described for evaluating and controlling quality of Yin Chen Hao Tang extract (YCHTE). First, HPLC-UV fingerprint chromatogram of YCHTE was established for preliminarily elucidating amount and chromatographic trajectory of chemical constituents in YCHTE. Second, for the first time, five mainly bioactive constituents in YCHTE were simultaneously determined based on fingerprint chromatogram for furthermore controlling the quality of YCHTE quantitatively. The developed method was applied to analyze 12 batches of YCHTE samples which consisted of herbal drugs from different places of production, showed acceptable linearity, intraday (RSD <5%), interday precision (RSD <4.80%), and accuracy (RSD <2.80%). As a result, fingerprint chromatogram determined 15 representative general fingerprint peaks, and the fingerprint chromatogram resemblances are all better than 0.9996. The contents of five analytes in different batches of YCHTE samples do not indicate significant difference. So, it is concluded that the developed HPLC-UV method is a more fully validated and complete method for evaluating and controlling the quality of YCHTE.

  3. ZnO nanofiber (NFs) growth from ZnO nanowires (NWs) by controlling growth temperature on flexible Teflon substrate by CBD technique for UV photodetector

    NASA Astrophysics Data System (ADS)

    Farhat, O. F.; Halim, M. M.; Ahmed, Naser M.; Qaeed, M. A.

    2016-12-01

    In this study, ZnO nanofibers (ZnO NFs) were successfully grown for the first time on Teflon substrates using CBD technique. The well-aligned ZnO nanorods (ZnO NRs) were transformed to ZnO nanofibers (NFs) by varying growth temperature and growth time. The high intensity and distinct growth orientation of peaks observed in the XRD spectra of the NFs indicate high crystal quality. The field emission scanning electron microscopy (FESEM) revealed high density of small diameter sized and long ZnO nanofibers (NFs) that are distributed in random directions. Raman analyses revealed a high E2 (high) peak at 436 nm, which indicates the wurtzite structure of ZnO. A flexible ZnO nanofiber (NFs)-based metal-semiconductor-metal UV detector was fabricated and analyzed for photo response and sensitivity under low power illumination (375 nm, 1.5 mW/cm2). The results showed a sensitivity of 4045% which can be considered a relatively high response and baseline recovery for UV detection.

  4. OCAPI: a multidirectional multichannel polarizing imager

    NASA Astrophysics Data System (ADS)

    Le Naour, C.; Eichen, G.; Léon, J. F.

    2017-11-01

    OCAPI (Optical Carbonaceous and anthropogenic Aerosols Pathfinder Instrument) is an imager dedicated to the observation of the spectral, directional and polarized signatures of the solar radiance reflected by the Earth-Atmosphere system. The measurements are used to study air quality and pollution by tracking aerosol quantity, types and circulation at various scales in the visible range. The main characteristics of OCAPI are a 110° along track and cross track field of view, eight polarized channels distributed between 320 and 2130 nm. The resolution is 4 x 4 km2 in the visible and the shortwave infrared (SWIR) range, and 10 x 10 km2 in the UV. The instrumental concept is derived from POLDER and PARASOL with additional channels in the UV and SWIR to better determine aerosol properties and constrain Earth surface and cloud contributions in the detected signal. It is based on three wide field-ofview telecentric optics (UV, Visible and SWIR), a rotating wheel bearing spectral and polarized filters and two dimensional detector arrays at the focal plane of the optics. The instrument requirements, concept and budgets are presented.

  5. A novel method to quantify the adulteration of extra virgin olive oil with low-grade olive oils by UV-vis.

    PubMed

    Torrecilla, José S; Rojo, Ester; Domínguez, Juan C; Rodríguez, Francisco

    2010-02-10

    A simple and novel method to quantify adulterations of extra virgin olive oil (EVOO) with refined olive oil (ROO) and refined olive-pomace oil (ROPO) is described here. This method consists of calculating chaotic parameters (Lyapunov exponent, autocorrelation coefficients, and two fractal dimensions, CPs) from UV-vis scans of adulterated EVOO samples. These parameters have been successfully linearly correlated with the ROO or ROPO concentrations in 396 EVOO adulterated samples. By an external validation process, when the adulterating agent concentration is less than 10%, the integrated CPs/UV-vis model estimates the adulterant agent concentration with a mean correlation coefficient (estimated versus real concentration of low grade olive oil) greater than 0.97 and a mean square error of less than 1%. In light of these results, this detector is suitable not only to detect adulterations but also to measure impurities when, for instance, a higher grade olive oil is transferred to another storage tank in which lower grade olive oil was stored that had not been adequately cleaned.

  6. Analysis of metalaxyl racemate using high performance liquid chromatography coupled with four kinds of detectors.

    PubMed

    Chen, Tao; Fan, Jun; Gao, Ruiqi; Wang, Tai; Yu, Ying; Zhang, Weiguang

    2016-10-07

    Chiral stationary phase-high performance liquid chromatography coupled with various detectors has been one of most commonly used methods for analysis and separation of chiral compounds over the past decades. Various detectors exhibit different characteristics in qualitative and quantitative studies under different chromatographic conditions. Herein, a comparative evaluation of HPLC coupled with ultraviolet, optical rotation, refractive index, and evaporative light scattering detectors has been conducted for qualitative and quantitative analyses of metalaxyl racemate. Effects of separation conditions on the peak area ratio between two enantiomers, including sample concentration, column temperature, mobile phase composition, as well as flow rate, have been investigated in detail. In addition, the limits of detection, the limits of quantitation, quantitative range and precision for these two enantiomers by using four detectors have been also studied. As indicated, the chromatographic separation conditions have been slight effects on ultraviolet and refractive index detections and the peak area ratio between two enantiomers remains almost unchanged, but the evaporative light scattering detection has been significantly affected by the above-mentioned chromatographic conditions and the corresponding peak area ratios varied greatly. Moreover, the limits of detection, the limits of quantitation, and the quantitative ranges of two enantiomers with UV detection were remarkably lower by 1-2 magnitudes than the others. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. High sensitivity microchannel plate detectors for space extreme ultraviolet missions.

    PubMed

    Yoshioka, K; Homma, T; Murakami, G; Yoshikawa, I

    2012-08-01

    Microchannel plate (MCP) detectors have been widely used as two-dimensional photon counting devices on numerous space EUV (extreme ultraviolet) missions. Although there are other choices for EUV photon detectors, the characteristic features of MCP detectors such as their light weight, low dark current, and high spatial resolution make them more desirable for space applications than any other detector. In addition, it is known that the photocathode can be tailored to increase the quantum detection efficiency (QDE) especially for longer UV wavelengths (100-150 nm). There are many types of photocathode materials available, typically alkali halides. In this study, we report on the EUV (50-150 nm) QDE evaluations for MCPs that were coated with Au, MgF(2), CsI, and KBr. We confirmed that CsI and KBr show 2-100 times higher QDEs than the bare photocathode MCPs, while Au and MgF(2) show reduced QDEs. In addition, the optimal geometrical parameters for the CsI deposition were also studied experimentally. The best CsI thickness was found to be 150 nm, and it should be deposited on the inner wall of the channels only where the EUV photons initially impinge. We will also discuss the techniques and procedures for reducing the degradation of the photocathode while it is being prepared on the ground before being deployed in space, as adopted by JAXA's EXCEED mission which will be launched in 2013.

  8. Low Energy X-Ray and γ-Ray Detectors Fabricated on n-Type 4H-SiC Epitaxial Layer

    NASA Astrophysics Data System (ADS)

    Mandal, Krishna C.; Muzykov, Peter G.; Chaudhuri, Sandeep K.; Terry, J. Russell

    2013-08-01

    Schottky barrier diode (SBD) radiation detectors have been fabricated on n-type 4H-SiC epitaxial layers and evaluated for low energy x- and γ-rays detection. The detectors were found to be highly sensitive to soft x-rays in the 50 eV to few keV range and showed 2.1 % energy resolution for 59.6 keV gamma rays. The response to soft x-rays for these detectors was significantly higher than that of commercial off-the-shelf (COTS) SiC UV photodiodes. The devices have been characterized by current-voltage (I-V) measurements in the 94-700 K range, thermally stimulated current (TSC) spectroscopy, x-ray diffraction (XRD) rocking curve measurements, and defect delineating chemical etching. I-V characteristics of the detectors at 500 K showed low leakage current ( nA at 200 V) revealing a possibility of high temperature operation. The XRD rocking curve measurements revealed high quality of the epitaxial layer exhibiting a full width at half maximum (FWHM) of the rocking curve 3.6 arc sec. TSC studies in a wide range of temperature (94-550 K) revealed presence of relatively shallow levels ( 0.25 eV) in the epi bulk with a density 7×1013 cm-3 related to Al and B impurities and deeper levels located near the metal-semiconductor interface.

  9. Simultaneous flame ionization and absorbance detection of volatile and nonvolatile compounds by reversed-phase liquid chromatography with a water mobile phase.

    PubMed

    Bruckner, C A; Ecker, S T; Synovec, R E

    1997-09-01

    A flame ionization detector (FID) is used to detect volatile organic compounds that have been separated by water-only reversed-phase liquid chromatography (WRP-LC). The mobile phase is 100% water at room temperature, without use of organic solvent modifiers. An interface between the LC and detector is presented, whereby a helium stream samples the vapor of volatile components from individual drops of the LC eluent, and the vapor-enriched gas stream is sent to the FID. The design of the drop headspace cell is simple because the water-only nature of the LC separation obviates the need to do any organic solvent removal prior to gas phase detection. Despite the absence of organic modifier, hydrophobic compounds can be separated in a reasonable time due to the low phase volume ratio of the WRP-LC columns. The drop headspace interface easily handles LC flows of 1 mL/min, and, in fact, compound detection limits are improved at faster liquid flow rates. The transfer efficiency of the headspace interface was estimated at 10% for toluene in water at 1 mL/min but varies depending on the volatility of each analyte. The detection system is linear over more than 5 orders of 1-butanol concentration in water and is able to detect sub-ppb amounts of o-xylene and other aromatic compounds in water. In order to analyze volatile and nonvolatile analytes simultaneously, the FID is coupled in series to a WRP-LC system with UV absorbance detection. WRP-LC improves UV absorbance detection limits because the absence of organic modifier allows the detector to be operated in the short-wavelength UV region, where analytes generally have significantly larger molar absorptivities. The selectivity the headspace interface provides for flame ionization detection of volatiles is demonstrated with a separation of 1-butanol, 1,1,2-trichloroethane (TCE), and chlorobenzene in a mixture of benzoic acid in water. Despite coelution of butanol and TCE with the benzoate anion, the nonvolatile benzoate anion does not appear in the FID signal, allowing the analytes of interest to be readily detected. The complementary selectivity of UV-visible absorbance detection and this implementation of flame ionization detection allows for the analysis of volatile and nonvolatile components of complex samples using WRP-LC without the requirement that all the components of interest be fully resolved, thus simplifying the sample preparation and chromatographic requirements. This instrument should be applicable to routine automated water monitoring, in which repetitive injection of water samples onto a gas chromatograph is not recommended.

  10. Detection of Extensive Cosmic Air Showers by Small Scintillation Detectors with Wavelength-Shifting Fibres

    ERIC Educational Resources Information Center

    Aiola, Salvatore; La Rocca, Paola; Riggi, Francesco; Riggi, Simone

    2012-01-01

    A set of three small scintillation detectors was employed to measure correlated events due to the passage of cosmic muons originating from extensive air showers. The coincidence rate between (any) two detectors was extracted as a function of their relative distance. The difference between the arrival times in three non-aligned detectors was used…

  11. Adaptive optical filter

    DOEpatents

    Whittemore, Stephen Richard

    2013-09-10

    Imaging systems include a detector and a spatial light modulator (SLM) that is coupled so as to control image intensity at the detector based on predetermined detector limits. By iteratively adjusting SLM element values, image intensity at one or all detector elements or portions of an imaging detector can be controlled to be within limits. The SLM can be secured to the detector at a spacing such that the SLM is effectively at an image focal plane. In some applications, the SLM can be adjusted to impart visible or hidden watermarks to images or to reduce image intensity at one or a selected set of detector elements so as to reduce detector blooming

  12. Mechanisms of Photo Degradation for Layered Silicate-Polycarbonate Nanocomposites

    DTIC Science & Technology

    2005-09-01

    crystal was used as the sampling accessory. The UV/VIS spectra were recorded using a Cary 5G UV/VIS/ near - infrared (NIR) spectrometer set to scan in...transform infrared spectroscopy. The results reveal that the carbonate linkages undergo a scission reaction upon UV exposure, thereby compromising the...were wiped clean before spectroscopic analysis. 3.3 Spectroscopic Measurements Infrared measurements were recorded on a Nicolet model 560 Magna

  13. Forecasting of UV-Vis absorbance time series using artificial neural networks combined with principal component analysis.

    PubMed

    Plazas-Nossa, Leonardo; Hofer, Thomas; Gruber, Günter; Torres, Andres

    2017-02-01

    This work proposes a methodology for the forecasting of online water quality data provided by UV-Vis spectrometry. Therefore, a combination of principal component analysis (PCA) to reduce the dimensionality of a data set and artificial neural networks (ANNs) for forecasting purposes was used. The results obtained were compared with those obtained by using discrete Fourier transform (DFT). The proposed methodology was applied to four absorbance time series data sets composed by a total number of 5705 UV-Vis spectra. Absolute percentage errors obtained by applying the proposed PCA/ANN methodology vary between 10% and 13% for all four study sites. In general terms, the results obtained were hardly generalizable, as they appeared to be highly dependent on specific dynamics of the water system; however, some trends can be outlined. PCA/ANN methodology gives better results than PCA/DFT forecasting procedure by using a specific spectra range for the following conditions: (i) for Salitre wastewater treatment plant (WWTP) (first hour) and Graz West R05 (first 18 min), from the last part of UV range to all visible range; (ii) for Gibraltar pumping station (first 6 min) for all UV-Vis absorbance spectra; and (iii) for San Fernando WWTP (first 24 min) for all of UV range to middle part of visible range.

  14. Development of an HPLC-UV Method for the Analysis of Drugs Used for Combined Hypertension Therapy in Pharmaceutical Preparations and Human Plasma.

    PubMed

    Kepekci Tekkeli, Serife Evrim

    2013-01-01

    A simple, rapid, and selective HPLC-UV method was developed for the determination of antihypertensive drug substances: amlodipine besilat (AML), olmesartan medoxomil (OLM), valsartan (VAL), and hydrochlorothiazide (HCT) in pharmaceuticals and plasma. These substances are mostly used as combinations. The combinations are found in various forms, especially in current pharmaceuticals as threesome components: OLM, AML, and HCT (combination I) and AML, VAL, and HCT (combination II). The separation was achieved by using an RP-CN column, and acetonitrile-methanol-10 mmol orthophosphoric acid pH 2.5 (7 : 13 : 80, v/v/v) was used as a mobile phase; the detector wavelength was set at 235 nm. The linear ranges were found as 0.1-18.5  μ g/mL, 0.4-25.6  μ g/mL, 0.3-15.5  μ g/mL, and 0.3-22  μ g/mL for AML, OLM, VAL, and HCT, respectively. In order to check the selectivity of the method for pharmaceutical preparations, forced degradation studies were carried out. According to the validation studies, the developed method was found to be reproducible and accurate as shown by RSD ≤6.1%, 5.7%, 6.9%, and 4.6% and relative mean error (RME) ≤10.6%, 5.8%, 6.5%, and 6.8% for AML, OLM, VAL, and HCT, respectively. Consequently, the method was applied to the analysis of tablets and plasma of the patients using drugs including those substances.

  15. [Occupational exposure of welders to ultraviolet and "blue light" radiation emitted during TIG and MMA welding based on field measurements].

    PubMed

    Wolska, Agnieszka

    2013-01-01

    The aim of the study was to present the results of welders' occupational exposure to "blue light" and UV radiation carried out at industrial workstations during TIG and MMA welding. Measurements were performed at 13 workstations (TIG welding: 6; MMA welding: 7), at which different welding parameters and materials were used. The radiation level was measured using a wide-range radiometer and a set of detectors, whose spectral responses were adequately fit to particular hazard under study. The measurement points corresponded with the location of eye and hand. The highest values of eye irradiance were found for aluminum TIG welding. Effective irradiance of actinic UV was within the range E(s) = 7.79-37.6 W/m2; UVA total irradiance, E(UVA) = 18-53.1 W/m2 and effective blue-light irradiance E(B) = 35-67 W/m2. The maximum allowance time ranged from 1.7 to 75 s, which means that in some cases even unintentional very short eye exposure can exceed MPE. The influence of welded material and the type of electrode coating on the measured radiation level were evidenced. The exceeded value of MPE for photochemical hazard arising for the eyes and skin was found at all measured workstations. Welders should use appropriately the eye and face protective equipment and avoid direct staring at welding arc when starting an arc-welding operation. Besides, the lack of head and neck skin protection can induce acute and chronic harmful health effects. Therefore, an appropriate wear of personal protective equipment is essential for welders' health.

  16. Biomass Burning Dominates Brown Carbon Absorption in the Rural Southeastern U.S.

    NASA Astrophysics Data System (ADS)

    Washenfelder, R. A.; Attwood, A. R.; Brock, C. A.; Brown, S. S.; Guo, H.; Weber, R. J. J.; Xu, L.; Ng, N. L.; Stone, E. A.; Edgerton, E. S.; Baumann, K.; Hu, W.; Palm, B. B.; Jimenez, J. L.; Fry, J.; Ayres, B. R.; Draper, D.; Allen, H.

    2014-12-01

    Aerosol scattering and absorption are still among the largest uncertainties in quantifying radiative forcing. Brown carbon has a wavelength-dependent absorption that increases in the UV spectral region, and its major atmospheric sources include biomass burning, anthropogenic combustion of fossil fuels, and secondary organic aerosol. The rural Southeastern U.S. is influenced by high isoprene concentrations and varying concentrations of biomass burning aerosol, making it an ideal place to compare the relative contributions of these two sources to the brown carbon absorption budget. During the Southern Oxidant and Aerosol Study in summer 2013, we deployed a new field instrument that uses cavity enhanced spectroscopy with a broadband light source to measure aerosol optical extinction as a function of wavelength. The instrument consists of two broadband channels which span the 360-390 and 385-420 nm spectral regions using two light emitting diodes (LED) and a grating spectrometer with charge-coupled device (CCD) detector. We combine these data with direct absorption measurements of water-soluble organic carbon obtained from a novel UV/VIS-WSOC instrument, and with aerosol composition measurements. We examine these data sets to determine: 1) the optical closure between measured dry aerosol extinction and values calculated from aerosol composition and size distribution; 2) the magnitude of brown and black carbon absorption; 3) the relative contributions of biomass burning, anthropogenic, and secondary organic aerosol contributions to brown carbon absorption in the Southeast U.S. during the summer. We conclude that biomass burning is a major contributor to optical absorption by organic aerosol in the rural southeastern U.S.

  17. Initial Characterization of Unequal-Length, Low-Background Proportional Counters for Absolute Gas-Counting Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mace, Emily K.; Aalseth, Craig E.; Bonicalzi, Ricco

    Abstract. Characterization of two sets of custom unequal length proportional counters is underway at Pacific Northwest National Laboratory (PNNL). These detectors will be used in measurements to determine the absolute activity concentration of gaseous radionuclides (e.g., 37Ar). A set of three detectors has been fabricated based on previous PNNL ultra-low-background proportional counters (ULBPC) designs and now operate in PNNL’s shallow underground counting laboratory. A second set of four counters has also been fabricated using clean assembly of OFHC copper components for use in an above-ground counting laboratory. Characterization of both sets of detectors is underway with measurements of background rates,more » gas gain, energy resolution, and shielding considerations. These results will be presented along with uncertainty estimates of future absolute gas counting measurements.« less

  18. Initial characterization of unequal-length, low-background proportional counters for absolute gas-counting applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mace, E. K.; Aalseth, C. E.; Bonicalzi, R.

    Characterization of two sets of custom unequal length proportional counters is underway at Pacific Northwest National Laboratory (PNNL). These detectors will be used in measurements to determine the absolute activity concentration of gaseous radionuclides (e.g., {sup 37}Ar). A set of three detectors has been fabricated based on previous PNNL ultra-low-background proportional counter designs and now operate in PNNL's shallow underground counting laboratory. A second set of four counters has also been fabricated using clean assembly of Oxygen-Free High-Conductivity copper components for use in a shielded above-ground counting laboratory. Characterization of both sets of detectors is underway with measurements of backgroundmore » rates, gas gain, and energy resolution. These results will be presented along with a shielding study for the above-ground cave.« less

  19. Determination of D-malic acid in apple juice by liquid chromatography: collaborative study.

    PubMed

    Eisele, T A

    1996-01-01

    Eleven laboratories collaboratively studied a liquid chromatographic (LC) method for determination of D-malic acid in apple juice. The mobile phase consisted of mM L-valine and 8 mM copper acetate adjusted to pH 5.5 with NaOH. The UV detector was set at 330 nm, and a single reversed-phase LC column was used. Seven paired samples containing various amounts of D-malic acid ranging from 0 to 188 mg/100 mL of 12 Brix pasteurized apple juice were tested by each collaborator. Repeatability and reproducibility coefficients of variation ranged from 1.0 to 3.5% and 7.7 to 11.7%, respectively, within the range of 26 to 188 mg D-malic acid/100 mL of 12 Brix apple juice. The collaborative study results demonstrated that the method could quantitate the economic adulteration of apple juice with DL-malic acid at lower levels than those reported with previous methods. The LC method for determination of D-malic acid in apple juice has been adopted first action by AOAC INTERNATIONAL.

  20. Rapid method for the determination of coumarin, vanillin, and ethyl vanillin in vanilla extract by reversed-phase liquid chromatography with ultraviolet detection.

    PubMed

    Ali, Laila; Perfetti, Gracia; Diachenko, Gregory

    2008-01-01

    A method is described for determining coumarin, vanillin, and ethyl vanillin in vanilla extract products. A product is diluted one-thousand-fold and then analyzed by reversed-phase liquid chromatography using a C18 column and a mobile phase consisting of 55% acetonitrile-45% aqueous acetic acid (1%) solution at a flow rate of 1.0 mL/min. Peaks are detected with a UV detector set at 275 nm. Vanilla extracts were spiked with 250, 500, and 1000 microg/g each of coumarin, vanillin, and ethyl vanillin. Recoveries averaged 97.4, 97.8, and 99.8% for coumarin, vanillin, and ethyl vanillin, respectively, with coefficient of variation values of 1.8, 1.3, and 1.3%, respectively. No significant difference was observed among the 3 spiking levels. A survey of 23 domestic and imported vanilla extract products was conducted using the method. None of the samples contained coumarin. The surveyed samples contained between 0.4 to 13.1 and 0.4 to 2.2 mg/g vanillin and ethyl vanillin, respectively.

  1. Detector power linearity requirements and verification techniques for TMI direct detection receivers

    NASA Technical Reports Server (NTRS)

    Reinhardt, Victor S. (Inventor); Shih, Yi-Chi (Inventor); Toth, Paul A. (Inventor); Reynolds, Samuel C. (Inventor)

    1997-01-01

    A system (36, 98) for determining the linearity of an RF detector (46, 106). A first technique involves combining two RF signals from two stable local oscillators (38, 40) to form a modulated RF signal having a beat frequency, and applying the modulated RF signal to a detector (46) being tested. The output of the detector (46) is applied to a low frequency spectrum analyzer (48) such that a relationship between the power levels of the first and second harmonics generated by the detector (46) of the beat frequency of the modulated RF signal are measured by the spectrum analyzer (48) to determine the linearity of the detector (46). In a second technique, an RF signal from a local oscillator (100) is applied to a detector (106) being tested through a first attenuator (102) and a second attenuator (104). The output voltage of the detector (106) is measured when the first attenuator (102) is set to a particular attenuation value and the second attenuator (104) is switched between first and second attenuation values. Further, the output voltage of the detector (106) is measured when the first attenuator (102) is set to another attenuation value, and the second attenuator (104) is again switched between the first and second attenuation values. A relationship between the voltage outputs determines the linearity of the detector (106).

  2. Riemann sum method for non-line-of-sight ultraviolet communication in noncoplanar geometry

    NASA Astrophysics Data System (ADS)

    Song, Peng; Zhou, Xianli; Song, Fei; Zhao, Taifei; Li, Yunhong

    2017-12-01

    The non-line-of-sight ultraviolet (UV) communication relies on the scattering common volume, however, it is difficult to carry out the triple integral operation of the scattering common volume. Based on UV single-scattering propagation theory and the spherical coordinate, we propose to use the Riemann sum method (RSM) to analyze the link path loss (PL) of UV communication system in noncoplanar geometries, and carried out related simulations. In addition, an outdoor testbed using UV light-emitting diode was set up to provide support for the validity of the RSM. When the elevation angles of the transmitter or the receiver are small, using RSM, the channel PL and temporal response of UV communication systems can be effectively and efficiently calculated. It is useful in UV embedded system design.

  3. Cloud point extraction of Δ9-tetrahydrocannabinol from cannabis resin.

    PubMed

    Ameur, S; Haddou, B; Derriche, Z; Canselier, J P; Gourdon, C

    2013-04-01

    A cloud point extraction coupled with high performance liquid chromatography (HPLC/UV) method was developed for the determination of Δ(9)-tetrahydrocannabinol (THC) in micellar phase. The nonionic surfactant "Dowfax 20B102" was used to extract and pre-concentrate THC from cannabis resin, prior to its determination with a HPLC-UV system (diode array detector) with isocratic elution. The parameters and variables affecting the extraction were investigated. Under optimum conditions (1 wt.% Dowfax 20B102, 1 wt.% Na2SO4, T = 318 K, t = 30 min), this method yielded a quite satisfactory recovery rate (~81 %). The limit of detection was 0.04 μg mL(-1), and the relative standard deviation was less than 2 %. Compared with conventional solid-liquid extraction, this new method avoids the use of volatile organic solvents, therefore is environmentally safer.

  4. A portable and autonomous multichannel fluorescence detector for on-line and in situ explosive detection in aqueous phase.

    PubMed

    Xin, Yunhong; Wang, Qi; Liu, Taihong; Wang, Lingling; Li, Jia; Fang, Yu

    2012-11-21

    A multichannel fluorescence detector used to detect nitroaromatic explosives in aqueous phase has been developed, which is composed of a five-channel sample-sensor unit, a measurement and control unit, a microcontroller, and a communication unit. The characteristics of the detector as developed are mainly embedded in the sensor unit, and each sensor consists of a fluorescent sensing film, a light emitting diode (LED), a multi-pixel photon counter (MPPC), and an optical module with special bandpass optical filters. Due to the high sensitivity of the sensing film, the small size and low cost of LED and MPPC, the developed detector not only has a better detecting performance and small size, but also has a very low cost - it is an alternative to the device made with an expensive high power lamp and photomultiplier tube. The wavelengths of the five sensors covered extend from the upper UV through the visible spectrum, 370-640 nm, and thereby it possesses the potential to detect a variety of explosives and other hazardous materials in aqueous phase. An additional function of the detector is its ability to function via a wireless network, by which the data recorded by the detector can be sent to the host computer, and at the same time the instructions can be sent to the detector from the host computer. By means of the powerful computing ability of the host computer, and utilizing the classical principal component analysis (PCA) algorithm, effective classification of the analytes is achieved. Furthermore, the detector has been tested and evaluated using NB, PA, TNT and DNT as the analytes, and toluene, benzene, methanol and ethanol as interferent compounds (concentration various from 10 and 60 μM). It has been shown that the detector can detect the four nitroaromatics with high sensitivity and selectivity.

  5. Can UV radiation-blocking soft contact lenses attenuate UV radiation to safe levels during summer months in the southern United States?

    PubMed

    Walsh, James E; Bergmanson, Jan P G; Saldana, Gerardo; Gaume, Amber

    2003-01-01

    Peak solar UV radiation (UVR) intensities are typically experienced in summer months. People living in the southern states of the United States, where the UVR frequently exceeds the recommended minimum erythema dose (MED), are at particular risk, especially outdoor workers. The present study analyzed summertime MED readings in Houston, TX, to assess the frequency of intensities regarded as unhealthy. The study also sought to assess whether UV-blocking hydrogel contact lenses provide ocular protection from these high doses. Readings, taken at midday using a UVR biometer, were analyzed to assess the potential UVR risk. The spectral response of the meter, modified by the spectral transmission curves of the contact lenses, allowed us to mathematically assess the ocular protection provided. In addition, ambient UVR measurements were taken at midday, using a portable UVR radiometer. The detector was adapted so that a standard diameter hydrogel contact lens could be placed over it to quantify the UV-blocking capabilities of the lens. The MED readings showed that the recommended safety standards were exceeded approximately at local midday 90% of the time. Model calculations and empirical data demonstrated that contact lenses attenuated the MED readings by up to 90%, bringing them well within the recommended Environmental Protection Agency safety standards. The efficacy of the model used in this study was verified through direct comparison of the modeled and measured data. UV-blocking hydrogel soft contact lenses reduce the MED to the human eye and therefore limit the lifetime ocular dose. These lenses are highly recommended to prevent the development of UVR-related ocular pathologic conditions.

  6. The Role of Channel Distribution Information for Interference Management and Network Performance Enhancement

    DTIC Science & Technology

    2010-11-03

    U,V wTp s.t. Γl ≥ γl,l = 1, . . . , L (2) For a fixed set of channel matrices Hli’s, this problem can be solved and will give a set of power...outage. The main optimization problem using CDI can then be formulated: min p≥0,U,V wTp s.t. Pr(Γl ≤ γl) ≤ αl, l = 1, . . . , L (3) In this formulation...can be written as min p≥0,U,V wTp s.t. 1− e− γl 2 σ2Nl cllpl ∏ i 6=l ( 1 + γl clipi cllpl )−1 ≤ αl, l = 1, . . . , L (11) To get the constraints in (11

  7. 29 CFR 801.1 - Purpose and scope.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (Federal, State, and local government employers are exempted from the Act) from using any lie detector... other types of lie detector tests, are permitted under limited circumstances subject to certain... detector use and the posting of notices. Subpart A also sets forth interpretations regarding the effect of...

  8. 29 CFR 801.1 - Purpose and scope.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (Federal, State, and local government employers are exempted from the Act) from using any lie detector... other types of lie detector tests, are permitted under limited circumstances subject to certain... detector use and the posting of notices. Subpart A also sets forth interpretations regarding the effect of...

  9. 29 CFR 801.1 - Purpose and scope.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (Federal, State, and local government employers are exempted from the Act) from using any lie detector... other types of lie detector tests, are permitted under limited circumstances subject to certain... detector use and the posting of notices. Subpart A also sets forth interpretations regarding the effect of...

  10. 29 CFR 801.1 - Purpose and scope.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (Federal, State, and local government employers are exempted from the Act) from using any lie detector... other types of lie detector tests, are permitted under limited circumstances subject to certain... detector use and the posting of notices. Subpart A also sets forth interpretations regarding the effect of...

  11. 29 CFR 801.1 - Purpose and scope.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (Federal, State, and local government employers are exempted from the Act) from using any lie detector... other types of lie detector tests, are permitted under limited circumstances subject to certain... detector use and the posting of notices. Subpart A also sets forth interpretations regarding the effect of...

  12. Online educative activities for solar ultraviolet radiation based on measurements of cloud amount and solar exposures.

    PubMed

    Parisi, A V; Downs, N; Turner, J; Amar, A

    2016-09-01

    A set of online activities for children and the community that are based on an integrated real-time solar UV and cloud measurement system are described. These activities use the functionality of the internet to provide an educative tool for school children and the public on the influence of cloud and the angle of the sun above the horizon on the global erythemal UV or sunburning UV, the diffuse erythemal UV, the global UVA (320-400nm) and the vitamin D effective UV. Additionally, the units of UV exposure and UV irradiance are investigated, along with the meaning and calculation of the UV index (UVI). This research will help ensure that children and the general public are better informed about sun safety by improving their personal understanding of the daily and the atmospheric factors that influence solar UV radiation and the solar UV exposures of the various wavebands in the natural environment. The activities may correct common misconceptions of children and the public about UV irradiances and exposure, utilising the widespread reach of the internet to increase the public's awareness of the factors influencing UV irradiances and exposures in order to provide clear information for minimizing UV exposure, while maintaining healthy, outdoor lifestyles. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. New photolysis system for NO2 measurements in the lower stratosphere

    NASA Technical Reports Server (NTRS)

    Gao, R. S.; Keim, E. R.; Woodbridge, E. L.; Ciciora, S. J.; Proffitt, M. H.; Thompson, T. L.; Mclaughlin, R. J.; Fahey, D. W.

    1994-01-01

    A new system for NO2 detection has been developed for use on the NASA ER-2 aircraft. The system converts NO2 to NO using UV photolysis with the NO product subsequently detected with an on-board chemiluminescence detector. The new system is compact, light weight, has high time resolution (approximately 1 s), and is significantly more efficient then some previous designs. Details of the system design and airborne performance are discussed.

  14. Device and method for determining oxygen concentration and pressure in gases

    DOEpatents

    Ayers, Michael R.; Hunt, Arlon J.

    1999-01-01

    Disclosed are oxygen concentration and/or pressure sensing devices and methods which incorporate photoluminescent silica aerogels. Disclosed sensors include a light proof housing for holding the photoluminescent aerogel, a source of excitation radiation (e.g., a UV source), a detector for detecting radiation emitted by the aerogel, a system for delivering a sample gas to the aerogel, and a thermocouple. Also disclosed are water resistant oxygen sensors having a photoluminescent aerogel coated with a hydrophobic material.

  15. A flash-lamp based device for fluorescence detection and identification of individual pollen grains.

    PubMed

    Kiselev, Denis; Bonacina, Luigi; Wolf, Jean-Pierre

    2013-03-01

    We present a novel optical aerosol particle detector based on Xe flash lamp excitation and spectrally resolved fluorescence acquisition. We demonstrate its performances on three natural pollens acquiring in real-time scattering intensity at two wavelengths, sub-microsecond time-resolved scattering traces of the particles' passage in the focus, and UV-excited fluorescence spectra. We show that the device gives access to a rather specific detection of the bioaerosol particles.

  16. Optimization of Composting for Explosives Contaminated Soil

    DTIC Science & Technology

    1991-09-30

    undesirable and essentially economically unfeasible for the remediation of small sites due to the large expenditures required for the mobilization and...mm, 5 micron. * Detector: UV absorbance at 250 nm. " Mobile phase: 52% methanol/48% water. " Flow rate: 1.5 mL/min. * Injection volume: 50 1&L. The...and lOx calibration standards. 4-21 57SC/2hif 12/02/91 Samples were diluted with mobile phase as necessary to bring target analytes into the

  17. High performance liquid chromatographic determination of caffeine in decaffeinated coffee, tea, and beverage products.

    PubMed

    Ashoor, S H; Seperich, G J; Monte, W C; Welty, J

    1983-05-01

    A method was developed for determining caffeine in decaffeinated coffee, tea, and beverage products by high performance liquid chromatography (HPLC). The HPLC system consisted of a Bio-Sil ODS-5S C18 column, methanol-water (25 + 75) mobile phase at 1 mL/min, and a UV detector. The method is simple and specific. Caffeine recoveries were 93.8-98.3% and coefficients of variation were 0.90-2.25%.

  18. HOW DO HOSPITAL STERILISATION PROCEDURES AFFECT THE RESPONSE OF PERSONAL EXTREMITY RINGS AND OF EYE LENS TL DOSEMETERS?

    PubMed

    Kopeć, Renata; Bubak, Anna; Budzanowski, Maciej; Sas-Bieniarz, Anna; Szumska, Agnieszka

    2016-09-01

    Stringent standards of hygiene must be applied in medical institutions, especially at operating blocks or during interventional radiology procedures. Medical equipment, including personal dosemeters that have to be worn by medical staff during such procedures, needs therefore to be sterilised. In this study, the effect of various sterilisation procedures has been tested on the dose response of extremity rings and of eye lens dosemeters in which thermoluminescent (TL) detectors (of types MTS-N and MCP-N, respectively) are used. The effects of medical sterilisation procedures were studied: by chemicals, by steam or by ultraviolet (UV), on the dose assessment by extremity rings and by eye lens dosemeters. Since it often happens that a dosemeter is accidentally machine-washed together with protective clothing, the effect of laundering on dose assessment by these dosemeters was also tested. The sterilisation by chemicals is mostly safe for TL detectors assuming that the dosemeters are waterproofed. Following sterilisation by water vapour, the response of these dosemeters diminished by some 30 %, irrespectively of the period of sterilisation; therefore, this method is not recommended. UV sterilisation can be applied to EYE-D™ eye lens dosemeters if their encapsulation is in black. The accidental dosemeter laundry in a washing machine has no impact on measured dose. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. High event rate ROICs (HEROICs) for astronomical UV photon counting detectors

    NASA Astrophysics Data System (ADS)

    Harwit, Alex; France, Kevin; Argabright, Vic; Franka, Steve; Freymiller, Ed; Ebbets, Dennis

    2014-07-01

    The next generation of astronomical photocathode / microchannel plate based UV photon counting detectors will overcome existing count rate limitations by replacing the anode arrays and external cabled electronics with anode arrays integrated into imaging Read Out Integrated Circuits (ROICs). We have fabricated a High Event Rate ROIC (HEROIC) consisting of a 32 by 32 array of 55 μm square pixels on a 60 μm pitch. The pixel sensitivity (threshold) has been designed to be globally programmable between 1 × 103 and 1 × 106 electrons. To achieve the sensitivity of 1 × 103 electrons, parasitic capacitances had to be minimized and this was achieved by fabricating the ROIC in a 65 nm CMOS process. The ROIC has been designed to support pixel counts up to 4096 events per integration period at rates up to 1 MHz per pixel. Integration time periods can be controlled via an external signal with a time resolution of less than 1 microsecond enabling temporally resolved imaging and spectroscopy of astronomical sources. An electrical injection port is provided to verify functionality and performance of each ROIC prior to vacuum integration with a photocathode and microchannel plate amplifier. Test results on the first ROICs using the electrical injection port demonstrate sensitivities between 3 × 103 and 4 × 105 electrons are achieved. A number of fixes are identified for a re-spin of this ROIC.

  20. The JEM-EUSO instrument

    NASA Astrophysics Data System (ADS)

    Adams, J. H.; Ahmad, S.; Albert, J.-N.; Allard, D.; Anchordoqui, L.; Andreev, V.; Anzalone, A.; Arai, Y.; Asano, K.; Ave Pernas, M.; Baragatti, P.; Barrillon, P.; Batsch, T.; Bayer, J.; Bechini, R.; Belenguer, T.; Bellotti, R.; Belov, K.; Berlind, A. A.; Bertaina, M.; Biermann, P. L.; Biktemerova, S.; Blaksley, C.; Blanc, N.; Błȩcki, J.; Blin-Bondil, S.; Blümer, J.; Bobik, P.; Bogomilov, M.; Bonamente, M.; Briggs, M. S.; Briz, S.; Bruno, A.; Cafagna, F.; Campana, D.; Capdevielle, J.-N.; Caruso, R.; Casolino, M.; Cassardo, C.; Castellinic, G.; Catalano, C.; Catalano, G.; Cellino, A.; Chikawa, M.; Christl, M. J.; Cline, D.; Connaughton, V.; Conti, L.; Cordero, G.; Crawford, H. J.; Cremonini, R.; Csorna, S.; Dagoret-Campagne, S.; de Castro, A. J.; De Donato, C.; de la Taille, C.; De Santis, C.; del Peral, L.; Dell'Oro, A.; De Simone, N.; Di Martino, M.; Distratis, G.; Dulucq, F.; Dupieux, M.; Ebersoldt, A.; Ebisuzaki, T.; Engel, R.; Falk, S.; Fang, K.; Fenu, F.; Fernández-Gómez, I.; Ferrarese, S.; Finco, D.; Flamini, M.; Fornaro, C.; Franceschi, A.; Fujimoto, J.; Fukushima, M.; Galeotti, P.; Garipov, G.; Geary, J.; Gelmini, G.; Giraudo, G.; Gonchar, M.; González Alvarado, C.; Gorodetzky, P.; Guarino, F.; Guzmán, A.; Hachisu, Y.; Harlov, B.; Haungs, A.; Hernández Carretero, J.; Higashide, K.; Ikeda, D.; Ikeda, H.; Inoue, N.; Inoue, S.; Insolia, A.; Isgrò, F.; Itow, Y.; Joven, E.; Judd, E. G.; Jung, A.; Kajino, F.; Kajino, T.; Kaneko, I.; Karadzhov, Y.; Karczmarczyk, J.; Karus, M.; Katahira, K.; Kawai, K.; Kawasaki, Y.; Keilhauer, B.; Khrenov, B. A.; Kim, J.-S.; Kim, S.-W.; Kim, S.-W.; Kleifges, M.; Klimov, P. A.; Kolev, D.; Kreykenbohm, I.; Kudela, K.; Kurihara, Y.; Kusenko, A.; Kuznetsov, E.; Lacombe, M.; Lachaud, C.; Lee, J.; Licandro, J.; Lim, H.; López, F.; Maccarone, M. C.; Mannheim, K.; Maravilla, D.; Marcelli, L.; Marini, A.; Martinez, O.; Masciantonio, G.; Mase, K.; Matev, R.; Medina-Tanco, G.; Mernik, T.; Miyamoto, H.; Miyazaki, Y.; Mizumoto, Y.; Modestino, G.; Monaco, A.; Monnier-Ragaigne, D.; Morales de los Ríos, J. A.; Moretto, C.; Morozenko, V. S.; Mot, B.; Murakami, T.; Murakami, M. Nagano; Nagata, M.; Nagataki, S.; Nakamura, T.; Napolitano, T.; Naumov, D.; Nava, R.; Neronov, A.; Nomoto, K.; Nonaka, T.; Ogawa, T.; Ogio, S.; Ohmori, H.; Olinto, A. V.; Orleański, P.; Osteria, G.; Panasyuk, M. I.; Parizot, E.; Park, I. H.; Park, H. W.; Pastircak, B.; Patzak, T.; Paul, T.; Pennypacker, C.; Perez Cano, S.; Peter, T.; Picozza, P.; Pierog, T.; Piotrowski, L. W.; Piraino, S.; Plebaniak, Z.; Pollini, A.; Prat, P.; Prévôt, G.; Prieto, H.; Putis, M.; Reardon, P.; Reyes, M.; Ricci, M.; Rodríguez, I.; Rodríguez Frías, M. D.; Ronga, F.; Roth, M.; Rothkaehl, H.; Roudil, G.; Rusinov, I.; Rybczyński, M.; Sabau, M. D.; Sáez-Cano, G.; Sagawa, H.; Saito, A.; Sakaki, N.; Sakata, M.; Salazar, H.; Sánchez, S.; Santangelo, A.; Santiago Crúz, L.; Sanz Palomino, M.; Saprykin, O.; Sarazin, F.; Sato, H.; Sato, M.; Schanz, T.; Schieler, H.; Scotti, V.; Segreto, A.; Selmane, S.; Semikoz, D.; Serra, M.; Sharakin, S.; Shibata, T.; Shimizu, H. M.; Shinozaki, K.; Shirahama, T.; Siemieniec-Oziȩbło, G.; Silva López, H. H.; Sledd, J.; Słomińska, K.; Sobey, A.; Sugiyama, T.; Supanitsky, D.; Suzuki, M.; Szabelska, B.; Szabelski, J.; Tajima, F.; Tajima, N.; Tajima, T.; Takahashi, Y.; Takami, H.; Takeda, M.; Takizawa, Y.; Tenzer, C.; Tibolla, O.; Tkachev, L.; Tokuno, H.; Tomida, T.; Tone, N.; Toscano, S.; Trillaud, F.; Tsenov, R.; Tsunesada, Y.; Tsuno, K.; Tymieniecka, T.; Uchihori, Y.; Unger, M.; Vaduvescu, O.; Valdés-Galicia, J. F.; Vallania, P.; Valore, L.; Vankova, G.; Vigorito, C.; Villaseñor, L.; von Ballmoos, P.; Wada, S.; Watanabe, J.; Watanabe, S.; Watts, J.; Weber, M.; Weiler, T. J.; Wibig, T.; Wiencke, L.; Wille, M.; Wilms, J.; Włodarczyk, Z.; Yamamoto, T.; Yamamoto, Y.; Yang, J.; Yano, H.; Yashin, I. V.; Yonetoku, D.; Yoshida, K.; Yoshida, S.; Young, R.; Zotov, M. Yu.; Zuccaro Marchi, A.

    2015-11-01

    In this paper we describe the main characteristics of the JEM-EUSO instrument. The Extreme Universe Space Observatory on the Japanese Experiment Module (JEM-EUSO) of the International Space Station (ISS) will observe Ultra High-Energy Cosmic Rays (UHECR) from space. It will detect UV-light of Extensive Air Showers (EAS) produced by UHECRs traversing the Earth's atmosphere. For each event, the detector will determine the energy, arrival direction and the type of the primary particle. The advantage of a space-borne detector resides in the large field of view, using a target volume of about 1012 tons of atmosphere, far greater than what is achievable from ground. Another advantage is a nearly uniform sampling of the whole celestial sphere. The corresponding increase in statistics will help to clarify the origin and sources of UHECRs and characterize the environment traversed during their production and propagation. JEM-EUSO is a 1.1 ton refractor telescope using an optics of 2.5 m diameter Fresnel lenses to focus the UV-light from EAS on a focal surface composed of about 5,000 multi-anode photomultipliers, for a total of ≃3ṡ105 channels. A multi-layer parallel architecture handles front-end acquisition, selecting and storing valid triggers. Each processing level filters the events with increasingly complex algorithms using FPGAs and DSPs to reject spurious events and reduce the data rate to a value compatible with downlink constraints.

Top