An infectious enteric adenovirus was isolated from urban wastewater receiving tertiary treatment and ultraviolet (UV) disinfection. A pilot study was undertaken to investigate the efficacy of UV disinfection (low pressure, high intensity radiation) of total and fecal coliform bac...
UV disinfection pilot plant study at the Savannah River Site
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huffines, R.L.; Beavers, B.A.
1993-05-01
An ultraviolet light disinfection system pilot plant was operated at the Savannah River Site Central Shops sanitary wastewater treatment package plant July 14, 1992 through August 13, 1992. The purpose was to determine the effectiveness of ultraviolet light disinfection on the effluent from the small package-type wastewater treatment plants currently used on-site. This pilot plant consisted of a rack of UV lights suspended in a stainless steel channel through which a sidestream of effluent from the treatment plant clarifier was pumped. Fecal coliform analyses were performed on the influent to and effluent from the pilot unit to verify the disinfectionmore » process. UV disinfection was highly effective in reducing fecal coliform colonies within NPDES permit limitations even under process upset conditions. The average fecal coliform reduction exceeded 99.7% using ultraviolet light disinfection under normal operating conditions at the package treatment plants.« less
UV disinfection pilot plant study at the Savannah River Site
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huffines, R.L.; Beavers, B.A.
1993-01-01
An ultraviolet light disinfection system pilot plant was operated at the Savannah River Site Central Shops sanitary wastewater treatment package plant July 14, 1992 through August 13, 1992. The purpose was to determine the effectiveness of ultraviolet light disinfection on the effluent from the small package-type wastewater treatment plants currently used on-site. This pilot plant consisted of a rack of UV lights suspended in a stainless steel channel through which a sidestream of effluent from the treatment plant clarifier was pumped. Fecal coliform analyses were performed on the influent to and effluent from the pilot unit to verify the disinfectionmore » process. UV disinfection was highly effective in reducing fecal coliform colonies within NPDES permit limitations even under process upset conditions. The average fecal coliform reduction exceeded 99.7% using ultraviolet light disinfection under normal operating conditions at the package treatment plants.« less
ULTRAVIOLET DISINFECTION OF A SECONDARY EFFLUENT: MEASUREMENT OF DOSE AND EFFECTS OF FILTRATION
Ultraviolet (UV) disinfection of wastewater secondary effluent was investigated in a two-phase study to develop methods for measuring UV dose and to determine the effects of filtration on UV disinfection. The first phase of this study involved a pilot plant study comparing filtra...
Zhao, Jin Hui; Chen, Wei; Zhao, Yaqian; Liu, Cuiyun; Liu, Ranbin
2015-01-01
The occurrence of carbon-bacteria complexes in activated carbon filtered water has posed a public health problem regarding the biological safety of drinking water. The application of combined process of ultraviolet radiation and nanostructure titanium dioxide (UV/TiO2) photocatalysis for the disinfection of carbon-bacteria complexes were assessed in this study. Results showed that a 1.07 Lg disinfection rate can be achieved using a UV dose of 20 mJ cm(-2), while the optimal UV intensity was 0.01 mW cm(-2). Particle sizes ≥8 μm decreased the disinfection efficiency, whereas variation in particle number in activated carbon-filtered water did not significantly affect the disinfection efficiency. Photoreactivation ratio was reduced from 12.07% to 1.69% when the UV dose was increased from 5 mJ cm(-2) to 20 mJ cm(-2). Laboratory and on-site pilot-scale experiments have demonstrated that UV/TiO2 photocatalytic disinfection technology is capable of controlling the risk posed by carbon-bacteria complexes and securing drinking water safety.
Tertiary treatment using microfiltration and UV disinfection for water reclamation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jolis, D.; Hirano, R.; Pitt, P.
Microfiltration and UV disinfection are two alternative technologies for water reclamation. The results of a pilot study combining these two processes are presented. In addition to producing filtrate turbidites averaging 0.06 nephelometric turbidity units, microfiltration was an effective barrier to pathogens, demonstrating average log reductions of 4.5 for total coliforms and 2.9 for MS2 bacteriophage. Ultraviolet disinfection following microfiltration reliably met the California Wastewater Reclamation Criteria (Title 22) total coliform standard of 2.2 colony-forming units/100 mL at a UV dose of 450 J/m{sup 2}. The MS2 bacteriophage standard, which requires a 5-log reduction, was achieved by microfiltration and a UVmore » dose of 880 J/m{sup 2}. A model of the kinetics of inactivation of MS2 bacteriophage was used in further analysis of disinfection data. The model indicated that considerable backmixing occurred in the pilot UV disinfection unit, and observed UV doses could be reduced with improved hydraulics.« less
Disinfection of low quality wastewaters by ultraviolet irradiation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zukovs, G.; Kollar, J.; Monteith, H.D.
1986-03-01
Pilot-scale disinfection of simulated combined sewer overflow (CSO) by ultraviolet light (UV) and by high-rate chlorination were compared. Disinfection efficiency was evaluated over a range of dosages and contact times for fecal coliforms, enterococci, P. Aeruginosa, and Salmonella spp. Fecal coliform were reduced 3.0 to 3.2 logs at a UV dose of approximately 350,000..mu.. W s/cm/sup 2/. High-rate chlorination, at a contact time of 2.0 minutes and total residual chlorine concentration of approximately 25 mg/L (as Cl/sub 2/), reduced fecal coliforms by 4.0 logs. Pathogens were reduced to detection limits by both processes. Neither photoreactivation nor regrowth occurred int hemore » disinfected effluents. The estimated capital costs of CSO disinfection by UV irradiation were consistently higher than for chlorination/dechlorination; operation and maintenance costs were similar. 19 references.« less
Wastewater disinfection alternatives: chlorine, ozone, peracetic acid, and UV light.
Mezzanotte, V; Antonelli, M; Citterio, S; Nurizzo, C
2007-11-01
Disinfection tests were carried out at pilot scale to compare the disinfection efficiency of ozone, sodium hypochlorite (NaOCl), peracetic acid (PAA), and UV irradiation. Total coliforms, fecal coliforms, and Escherichia coli were monitored as reference microorganisms. Total heterotrophic bacteria (THB) were also enumerated by cytometry. At similar doses, NaOCl was more effective than PAA, and its action was less affected by contact time. The results obtained by ozonation were comparable for total coliforms, fecal coliforms, and E. coli. On the contrary, some differences among the three indicators were observed for NaOCl, PAA, and UV. Differences increased with increasing values of the disinfectant concentration times contact time (C x t) and were probably the result of different initial counts, as total coliforms include fecal coliforms, which include E. coli. The UV irradiation lead to complete E. coli removals, even at low doses (10 to 20 mJ/cm2). Total heterotrophic bacteria appeared to be too wide a group to be a good disinfection indicator; no correlation was found among THB inactivation, dose, and contact time.
Jungfer, Christina; Friedrich, Frank; Varela Villarreal, Jessica; Brändle, Katharina; Gross, Hans-Jürgen; Obst, Ursula; Schwartz, Thomas
2013-09-01
Biofilms growing on copper and stainless steel substrata in natural drinking water were investigated. A modular pilot-scale distribution facility was installed at four waterworks using different raw waters and disinfection regimes. Three-month-old biofilms were analysed using molecular biology and microscopy methods. High total cell numbers, low counts of actively respiring cells and low numbers of cultivable bacteria indicated the high abundance of viable but not cultivable bacteria in the biofilms. The expression of the recA SOS responsive gene was detected and underlined the presence of transcriptionally active bacteria within the biofilms. This effect was most evident after UV disinfection, UV oxidation and UV disinfection with increased turbidity at waterworks compared to chemically treated and non-disinfected systems. Furthermore, live/dead staining techniques and environmental scanning electron microscopy imaging revealed the presence of living and intact bacteria in biofilms on copper substrata. Cluster analyses of DGGE profiles demonstrated differences in the composition of biofilms on copper and steel materials.
Friedler, Eran; Gilboa, Yael
2010-04-01
This paper examines the microbial quality of treated RBC (Rotating Biological Contactor) and MBR (Membrane Bioreactor) light greywater along a continuous pilot-scale reuse system for toilet flushing, quantifies the efficiency of UV disinfection unit, and evaluates the regrowth potential of selected microorganisms along the system. The UV disinfection unit was found to be very efficient in reducing faecal coliforms and Staphylococcus aureus. On the other hand, its efficiency of inactivation of HPC (Heterotrophic Plate Count) and Pseudomonas aeruginosa was lower. Some regrowth occurred in the reuse system as a result of HPC regrowth which included opportunistic pathogens such as P. aeruginosa. Although the membrane (UF) of the MBR system removed all bacteria from the greywater, bacteria were observed in the reuse system due to "hopping phenomenon." The microbial quality of the disinfected greywater was found to be equal or even better than the microbial quality of "clean" water in toilet bowls flushed with potable water (and used for excretion). Thus, the added health risk associated with reusing the UV-disinfected greywater for toilet flushing (regarding P. aeruginosa and S. aureus), was found to be insignificant. The UV disinfection unit totally removed (100%) the viral indicator (F-RNA phage, host: E. coli F(amp)(+)) injected to the treatment systems simulating transient viral contamination. To conclude, this work contributes to better design of UV disinfection reactors and provides an insight into the long-term behavior of selected microorganisms along on-site greywater reuse systems for toilet flushing. (c) 2010 Elsevier B.V. All rights reserved.
González, Abelardo; Gehr, Ronald; Vaca, Mabel; López, Raymundo
2012-03-01
Disinfection of an advanced primary effluent using a continuous-flow combined peracetic acid/ultraviolet (PAA/UV) radiation system was evaluated. The purpose was to determine whether the maximum microbial content, established under Mexican standards for treated wastewaters meant for reuse--less than 240 most probable number fecal coliforms (FC)/100 mL--could be feasibly accomplished using either disinfectant individually, or the combined PAA/UV system. This meant achieving reduction of up to 5 logs, considering initial concentrations of 6.4 x 10(+6) to 5.8 x 10(+7) colony forming units/100 mL. During the tests performed under these experiments, total coliforms (TC) were counted because FC, at the most, will be equal to TC. Peracetic acid disinfection achieved less than 1.5 logs TC reduction when the C(t) x t product was less than 2.26 mg x minimum (min)/L; 3.8 logs for C(t) x t 4.40 mg x min/L; and 5.9 logs for C(t) x t 24.2 mg x min/L. In continuous-flow UV irradiation tests, at a low-operating flow (21 L/min; conditions which produced an average UV fluence of 13.0 mJ/cm2), the highest TC reduction was close to 2.5 logs. The only condition that produced a disinfection efficiency of approximately 5 logs, when both disinfection agents were used together, was the combined process dosing 30 mg PAA/L at a pilot plant flow of 21 L/min and contact time of 10 minutes to attain an average C(t) x t product of 24.2 mg x min/L and an average UV fluence of 13 mJ/cm2. There was no conclusive evidence of a synergistic effect when both disinfectants were employed in combination as compared to the individual effects achieved when used separately, but this does not take into account the nonlinearity (tailing-off) of the dose-response curve.
Evaluation of Combined Peracetic acid and UV treatment for ...
The current study evaluates the effectiveness of the combined application of Peracetic acid and ultraviolet radiation as alternative disinfectant agents to the traditional chlorination of wastewater effluents. Various pathogens (E. coli, enterococci and fecal coliforms) were evaluated in the study. Four experiments were conducted using low to high PAA levels and UV dosages. E. coli and enterococci were resistant to low to moderate PAA dosage (0.5- 1 mg/L). These microbes can be removed effectively at high PAA dosage (2.5 mg/L) with 30 min contact time. Fecal coliforms were completely inactivated even at a low PAA dose of 0.7 mg/L. E. coli was more susceptible to UV disinfection than enterococci at low UV dosages. Enterococci required at least 40 mJ/cm2 for 2.5 log inactivation. In combined PAA + UV treatment, low UV intensities between 7 – 40 mJ/cm2 showed poor disinfection performance at a low PAA concentration of 1.5 mg/L. High UV intensities of 120 and 60 mJ/cm2 inactivated all the pathogens to below detection levels even at low to moderate PAA (0.7 mg/L and 1 mg/L) pretreatment concentration. Combined PAA + UV treatment at 1 mg/L (for 15 and 30 min contact time) + 120 and 60 mJ/cm2 did not show any regrowth of microbes, whereas PAA only disinfection with 15 min contact time showed regrowth of enterococci and fecal coliforms. UV only disinfection showed E. coli regrowth. • This pilot scale study was designed for providing necessary parameter optimization
Particle effects on ultraviolet disinfection of coliform bacteria in recycled water.
Jolis, D; Lam, C; Pitt, P
2001-01-01
Pilot- and bench-scale coliform inactivation tests with UV irradiation were used to show how suspended solids remaining in filtered secondary effluent affect the efficiency of the UV disinfection process. Observed kinetic inactivation rates decreased with increasing suspended particle sizes of 7 microm or larger present in tertiary effluent. First-order inactivation rates estimated from collimated beam dose-response curves for discrete ranges of UV doses were substantially different, which should caution researchers not to compare inactivation data obtained with largely dissimilar UV doses or suspended particle distributions. A dose of approximately 800 J/m2 was identified as the minimum dose that will consistently meet the California wastewater reclamation coliform criterion when applied to in-line filtration effluent.
Långmark, Jonas; Storey, Michael V.; Ashbolt, Nicholas J.; Stenström, Thor-Axel
2005-01-01
The accumulation and fate of model microbial “pathogens” within a drinking-water distribution system was investigated in naturally grown biofilms formed in a novel pilot-scale water distribution system provided with chlorinated and UV-treated water. Biofilms were exposed to 1-μm hydrophilic and hydrophobic microspheres, Salmonella bacteriophages 28B, and Legionella pneumophila bacteria, and their fate was monitored over a 38-day period. The accumulation of model pathogens was generally independent of the biofilm cell density and was shown to be dependent on particle surface properties, where hydrophilic spheres accumulated to a larger extent than hydrophobic ones. A higher accumulation of culturable legionellae was measured in the chlorinated system compared to the UV-treated system with increasing residence time. The fate of spheres and fluorescence in situ hybridization-positive legionellae was similar and independent of the primary disinfectant applied and water residence time. The more rapid loss of culturable legionellae compared to the fluorescence in situ hybridization-positive legionellae was attributed to a loss in culturability rather than physical desorption. Loss of bacteriophage 28B plaque-forming ability together with erosion may have affected their fate within biofilms in the pilot-scale distribution system. The current study has demonstrated that desorption was one of the primary mechanisms affecting the loss of microspheres, legionellae, and bacteriophage from biofilms within a pilot-scale distribution system as well as disinfection and biological grazing. In general, two primary disinfection regimens (chlorination and UV treatment) were not shown to have a measurable impact on the accumulation and fate of model microbial pathogens within a water distribution system. PMID:15691920
Långmark, Jonas; Storey, Michael V; Ashbolt, Nicholas J; Stenström, Thor-Axel
2005-02-01
The accumulation and fate of model microbial "pathogens" within a drinking-water distribution system was investigated in naturally grown biofilms formed in a novel pilot-scale water distribution system provided with chlorinated and UV-treated water. Biofilms were exposed to 1-mum hydrophilic and hydrophobic microspheres, Salmonella bacteriophages 28B, and Legionella pneumophila bacteria, and their fate was monitored over a 38-day period. The accumulation of model pathogens was generally independent of the biofilm cell density and was shown to be dependent on particle surface properties, where hydrophilic spheres accumulated to a larger extent than hydrophobic ones. A higher accumulation of culturable legionellae was measured in the chlorinated system compared to the UV-treated system with increasing residence time. The fate of spheres and fluorescence in situ hybridization-positive legionellae was similar and independent of the primary disinfectant applied and water residence time. The more rapid loss of culturable legionellae compared to the fluorescence in situ hybridization-positive legionellae was attributed to a loss in culturability rather than physical desorption. Loss of bacteriophage 28B plaque-forming ability together with erosion may have affected their fate within biofilms in the pilot-scale distribution system. The current study has demonstrated that desorption was one of the primary mechanisms affecting the loss of microspheres, legionellae, and bacteriophage from biofilms within a pilot-scale distribution system as well as disinfection and biological grazing. In general, two primary disinfection regimens (chlorination and UV treatment) were not shown to have a measurable impact on the accumulation and fate of model microbial pathogens within a water distribution system.
Titanium dioxide/UV photocatalytic disinfection in fresh carrots.
Cho, Mihee; Choi, Yoonjung; Park, Hyojin; Kim, Kwansik; Woo, Gun-Jo; Park, Jiyong
2007-01-01
Increased occurrences of fresh produce-related outbreaks of foodborne illness have focused attention on effective washing processes for fruits and vegetables. A titanium dioxide (TiO2) photocatalytic reaction under UV radiation provides a high rate of disinfection. The photo-killing effects of TiO2 on bacteria in liquid cultures under experimental conditions have been widely studied. However, the disinfection effects of the TiO2 photocatalytic reaction on fresh vegetables during a washing process have not been evaluated. Our objectives were to design a pilot-scale TiO2/UV photocatalytic reactor for fresh carrots and to compare the bactericidal effects of the TiO2/UV reaction against bacteria in liquid media and on carrots. TiO2/UV photocatalytic reactions for 40, 60, and 30 s were required for the complete killing of Escherichia coli, Salmonella Typhimurium, and Bacillus cereus (initial counts of approximately 6.7 log CFU/ml), respectively. The counts of total aerobic bacteria in fresh carrots and foodborne pathogenic bacteria in inoculated carrots were also measured. Counts of total aerobic bacteria were reduced by 1.8 log CFU/g after TiO2/UV photocatalytic disinfection for 20 min compared with a 1.1-log CFU/g reduction by UV alone. E. coli, Salmonella Typhimurium, and B. cereus (8 log CFU/ml) were inoculated onto carrots, and the number of surviving bacteria in carrots was determined after treatment. The TiO2/UV treatment exhibited 2.1-, 2.3-, and 1.8-log CFU/g reductions in the counts of E. coli, Salmonella Typhimurium, and B. cereus, respectively, compared with 1.3-, 1.2-, and 1.2-log CFU/g reductions by UV alone. The TiO2/UV photocatalyst reaction showed significant bactericidal effects, indicating that this process is applicable to nonthermal disinfection of fresh vegetables.
Álvarez, J A; Ávila, C; Otter, P; Kilian, R; Istenič, D; Rolletschek, M; Molle, P; Khalil, N; Ameršek, I; Mishra, V K; Jorgensen, C; Garfi, A; Carvalho, P; Brix, H; Arias, C A
2017-09-01
SWINGS was a cooperation project between the European Union and India, aiming at implementing state of the art low-cost technologies for the treatment and reuse of domestic wastewater in rural areas of India. The largest wastewater treatment plant consists of a high-rate anaerobic system, followed by vertical and horizontal subsurface flow constructed wetlands with a treatment area of around 1,900 m 2 and a final step consisting of solar-driven anodic oxidation (AO) and ultraviolet (UV) disinfection units allowing direct reuse of the treated water. The implementation and operation of two pilot plants in north (Aligarh Muslim University, AMU) and central India (Indira Gandhi National Tribal University, IGNTU) are shown in this study. The overall performance of AMU pilot plant during the first 7 months of operation showed organic matter removal efficiencies of 87% total suspended solids, 95% 5-day biological oxygen demand (BOD 5 ) and 90% chemical oxygen demand, while Kjeldahl nitrogen removal reached 89%. The UV disinfection unit produces water for irrigation and toilet flushing with pathogenic indicator bacteria well below WHO guidelines. On the other hand, the AO disinfection unit implemented at IGNTU and operated for almost a year has been shown to produce an effluent of sufficient quality to be reused by the local population for agriculture and irrigation.
Napolitano, Nathanael A; Mahapatra, Tanmay; Tang, Weiming
2015-12-01
Health care-acquired infections (HAIs) constitute an increasing threat for patients worldwide. Potential contributors of HAIs include environmental surfaces in health care settings, where ultraviolet-C radiation (UV-C) is commonly used for disinfection. This UV-C intervention-based pilot study was conducted in a hospital setting to identify any change in the incidence of HAIs before and after UV-C intervention, and to determine the effectiveness of UV-C in reducing pathogens. In a hospital in Culver City, CA, during 2012-2013, bactericidal doses of UV-C radiation (254 nm) were delivered through a UV-C-based mobile environmental decontamination unit. The UV-C dosing technology and expertise of the specifically trained personnel were provided together as a dedicated service model by a contracted company. The incidence of HAIs before and after the intervention period were determined and compared. The dedicated service model dramatically reduced HAIs (incidence difference, 1.3/1000 patient-days, a 34.2% reduction). Reductions in the total number and incidence proportions (28.8%) of HAIs were observed after increasing and maintaining the coverage of UV-C treatments. The dedicated service model was found to be effective in decreasing the incidence of HAIs, which could reduce disease morbidity and mortality in hospitalized patients. This model provides a continuously monitored and frequently UV-C-treated patient environment. This approach to UV-C disinfection was associated with a decreased incidence of HAIs. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Peracetic acid for secondary effluent disinfection: a comprehensive performance assessment.
Antonelli, M; Turolla, A; Mezzanotte, V; Nurizzo, C
2013-01-01
The paper is a review of previous research on secondary effluent disinfection by peracetic acid (PAA) integrated with new data about the effect of a preliminary flash-mixing step. The process was studied at bench and pilot scale to assess its performance for discharge in surface water and agricultural reuse (target microorganisms: Escherichia coli and faecal coliform bacteria). The purposes of the research were: (1) determining PAA decay and disinfection kinetics as a function of operating parameters, (2) evaluating PAA suitability as a disinfectant, (3) assessing long-term disinfection efficiency, (4) investigating disinfected effluent biological toxicity on some aquatic indicator organisms (Vibrio fischeri, Daphnia magna and Selenastrum capricornutum), (5) comparing PAA with conventional disinfectants (sodium hypochlorite, UV irradiation). PAA disinfection was capable of complying with Italian regulations on reuse (10 CFU/100 mL for E. coli) and was competitive with benchmarks. No regrowth phenomena were observed, as long as needed for agricultural reuse (29 h after disinfection), even at negligible concentrations of residual disinfectant. The toxic effect of PAA on the aquatic environment was due to the residual disinfectant in the water, rather than to chemical modification of the effluent.
Design and bidding of UV disinfection equipment -- Case study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akyurek, M.
1998-07-01
Ultraviolet (UV) disinfection systems are being widely considered for application to treated wastewaters, in lieu of conventional chlorination facilities. The number of UV systems operating in the US was approximately 50 in 1984. In 1990 there were over 500 systems, a ten-fold increase. The use of UV disinfection has increased since 1990, and will likely to increase in the future. It is anticipated that as many chlorine disinfection facilities reach their useful life, most of them will be replaced with UV disinfection systems. Several manufacturers offer different UV disinfection equipment. Each offers something different for the designer. There are alsomore » different approaches used in estimating the number of lamps needed for the disinfection system. The lack of standardization in determination of the number of lamps for a UV system poses problems for the designer. Such was the case during the design of the disinfection system for the Watertown, SD Wastewater Treatment Plant (WWRP). The purpose of this paper is to present a case study for the design and bidding of UV disinfection equipment.« less
Jin, Xin; Li, Zifu; Xie, Lanlan; Zhao, Yuan; Wang, Tingting
2013-11-01
The ultraviolet (UV) disinfection efficiency is often affected by suspended solids (SS). Given their high concentration or large particle size, SS can scatter UV light and provide shielding for bacteria. Thus, ultrasound is often employed as a pre-treatment process to improve UV disinfection. This work investigated the synergistic effect of ultrasound combined with UV for secondary effluent disinfection. Bench-scale experiments were conducted in using samples obtained from secondary sedimentation tanks. These tanks belonged to three wastewater treatment plants in Beijing that use different kinds of biological treatment methods. Several parameters may contribute to the changes in the efficiency of ultrasound and UV disinfection. Thus, the frequency and energy density of ultrasound, as well as the SS, were investigated. Results demonstrated that samples which have relatively higher SS concentrations or higher percentages of larger particles have less disinfection efficiency using UV disinfection alone. However, the presence of ultrasound could improve the disinfection efficiency because it has synergistic effect. Changes in the particle size distribution and SS concentration notably affected the efficiency of UV disinfection. The efficiency of Escherichia coli elimination can be decreased by 1.2 log units as the SS concentration increases from 16.9 mg/l to 25.4 mg/l at a UV energy density of 40 mJ/cm(2). UV disinfection alone reduced the E. coli population by 3.4 log units. However, the synergistic disinfection of ultrasound and UV could reach 5.4 log units during the reduction of E. coli at a 40 kHz frequency and an energy density of 2.64 kJ/l. The additional synergistic effect is 1.1 log units. Copyright © 2013 Elsevier B.V. All rights reserved.
UV disinfection in drinking water supplies.
Hoyer, O
2000-01-01
UV disinfection has become a practical and safely validatable disinfection procedure by specifying the requirements for testing and monitoring in DVGW standard W 294. A standardized biodosimetric testing procedure and monitoring with standardized UV sensors is introduced and successfully applied. On-line monitoring of irradiance can be counterchecked with handheld reference sensors and makes it possible that UV systems can be used for drinking water disinfection with the same level of confidence and safety as is conventional chemical disinfection.
UV Disinfection of Wastewater and Combined Sewer Overflows.
Gibson, John; Drake, Jennifer; Karney, Bryan
2017-01-01
Municipal wastewater contains bacteria, viruses, and other pathogens that adversely affect the environment, human health, and economic activity. One way to mitigate these effects is a final disinfection step using ultraviolet light (UVL). The advantages of UVL disinfection, when compared to the more traditional chlorine, include no chlorinated by-products, no chemical residual, and relatively compact size. The design of most UV reactors is complex. It involves lamp selection, power supply design, optics, and hydraulics. In general, medium pressure lamps are more compact, powerful, and emit over a wider range of light than the more traditional low pressure lamps. Low pressure lamps, however, may be electrically more efficient. In UV disinfection, the fraction of surviving organisms (e.g. E. coli) will decrease exponentially with increasing UV dose. However, the level of disinfection that can be achieved is often limited by particle-associated organisms. Efforts to remove or reduce the effects of wastewater particles will often improve UV disinfection effectiveness. Regrowth, photoreactivation, or dark repair after UV exposure are sometimes cited as disadvantages of UV disinfection. Research is continuing in this area, however there is little evidence that human pathogens can photoreactivate in environmental conditions, at doses used in wastewater treatment. The UV disinfection of combined sewer overflows, a form of wet weather pollution, is challenging and remains largely at the research phase. Pre-treatment of combined sewer overflows (CSOs) with a cationic polymer to induce fast settling, and a low dose of alum to increase UV transmittance, has shown promise at the bench scale.
ULTRAVIOLET DISINFECTION STUDIES WITH CCL LISTED MICROORGANISMS
Resistance to ultraviolet (UV) disinfection is an essential aspect regarding all microbial groups listed on the CCL. The U.S. drinking water industry is interested in including UV light treatment as an amendment to conventional treatment for disinfecting water supplies. UV disi...
Biodiesel from wastewater: lipid production in high rate algal pond receiving disinfected effluent.
Assemany, Paula Peixoto; Calijuri, Maria Lucia; do Couto, Eduardo de Aguiar; Santiago, Aníbal Fonseca; Dos Reis, Alberto José Delgado
2015-01-01
The production of different species of microalgae in consortium with other micro-organisms from wastewaters may represent an alternative process, to reduce the costs, for obtaining biofuels. The aim of this study was to evaluate the influence of pre-ultraviolet disinfection (UV) in the production of lipids from biomass produced in high rate ponds. Two high rate algal ponds were evaluated: a pond that received domestic sewage without disinfection and the other receiving domestic sewage previously disinfected by UV radiation (uvHRAP). The UV disinfection did not lead to significant differences in fatty acid profile and total lipid productivities, although it increased algal biomass concentration and productivity as well as lipid content. Moreover, the overall biomass concentrations and productivities decreased with the UV disinfection, mostly as a consequence of a loss in bacterial load. We thus conclude that uvHRAP disinfection may represent a potential strategy to promote the cleaner and safer growth of algal biomass when cultivated in consortium with other micro-organisms. Mainly regarding the use of wastewater as culture medium, together with a cheaper production of lipids for biodiesel, pre-disinfection may represent an advance since extraction costs could be significantly trimmed due to the increase in lipid content.
Ultraviolet (UV) Disinfection for Drinking Water Systems
UV disinfection is an effective process for inactivating many microbial pathogens in water with potential to serve as stand-alone treatment or in combination with other disinfectants. USEPA provided guidance on the validation of UV reactors nearly a decade ago. Since then, lesson...
Role of ultraviolet (UV) disinfection in infection control and environmental cleaning.
Qureshi, Zubair; Yassin, Mohamed H
2013-06-01
Ultraviolet (UV) radiation is capable of disinfecting surfaces, water and air. The UV technology was used for many years. However, safer and more effective delivery systems of UV radiation, make it a very useful option for disinfection. Effective disinfection of environmental surfaces is a key step in the prevention of spread of infectious agents. The traditional manual cleaning is essential in assuring adequate elimination of contamination. However, terminal cleaning is frequently suboptimal or unpredictable in many circumstances. UV-C radiation is an adjunctive disinfectant new technology that could kill a wide array of microorganisms including both vegetative and spore forming pathogens. The technology is getting more affordable and has produced consistent reproducible significant reduction of bacterial contamination.
COMPARATIVE DISINFECTION EFFICIENCY OF PULSED AND CONTINUOUS-WAVE UV IRRADIATION TECHNOLOGIES
Pulsed UV (PUV) is novel UV irradiation system that is a non-mercury lamp based alternative to currently used continuous-wave systems for water disinfection. To compare the polychromatic PUV irradiation disinfection efficiency with that from continuous wave monochromatic low-pre...
Jinadatha, Chetan; Villamaria, Frank C; Restrepo, Marcos I; Ganachari-Mallappa, Nagaraja; Liao, I-Chia; Stock, Eileen M; Copeland, Laurel A; Zeber, John E
2015-08-01
Methicillin-resistant Staphylococcus aureus (MRSA) has been shown to survive on ambient surfaces for extended periods of time. Leftover MRSA environmental contamination in a hospital room places future patients at risk. Manual disinfection supplemented by pulsed xenon ultraviolet (PX-UV) light disinfection has been shown to greatly decrease the MRSA bioburden in hospital rooms. However, the effect of PX-UV in the absence of manual disinfection has not been evaluated. Rooms that were previously occupied by a MRSA-positive patient (current colonization or infection) were selected for the study immediately postdischarge. Five high-touch surfaces were sampled, before and after PX-UV disinfection, in each hospital room. The effectiveness of the PX-UV device on the concentration of MRSA was assessed employing a Wilcoxon signed-rank test for all 70 samples with MRSA in 14 rooms, as well as by surface location. The final analysis included 14 rooms. Before PX-UV disinfection there were a total of 393 MRSA colonies isolated from the 5 high-touch surfaces. There were 100 MRSA colonies after disinfection by the PX-UV device and the overall reduction was statistically significant (P < .01). Our study results suggest that PX-UV light effectively reduces MRSA colony counts in the absence of manual disinfection. These findings are important for hospital and environmental services supervisors who plan to adapt new technologies as an adjunct to routine manual disinfection. Published by Elsevier Inc.
Feasibility of the silver-UV process for drinking water disinfection.
Butkus, Michael A; Talbot, Mark; Labare, Michael P
2005-12-01
A synergistic effect between cationic silver and UV radiation (silver-UV disinfection) has been observed that can appreciably enhance inactivation of viruses. The purpose of this work was to assess the feasibility of this technique for drinking water disinfection and evaluate the effects of selected impurities, found in fresh water, and common parameters on inactivation of the coliphage MS-2 with the silver-UV process. Turbidity (kaolin), calcium hardness, carbonate alkalinity, and pH did not significantly degrade inactivation. Inactivation was reduced in the presence of chloride, at concentrations greater than 30 mg/L, and in water samples with UV-254 absorbance values greater than ca. 0.1 cm(-1). Inactivation of MS-2 with silver-UV disinfection was also reduced at high phosphate concentrations (above ca. 5 mM). Silver-UV inactivation of MS-2 increased with increases in temperature between 10 and 20 degrees C. Silver-UV inactivation of MS-2 was increased by greater than 1-log over UV alone, in two untreated fresh water sources, which indicates that silver-UV may be a viable treatment technology. An assessment of operation and management costs suggests that an increase in inactivation of MS-2 with silver-UV disinfection could be economically beneficial.
dos Santos, Luciana Urbano; Alves, Delma Pegolo; Guaraldo, Ana Maria Aparecida; Cantusio Neto, Romeu; Durigan, Mauricio; Franco, Regina Maura Bueno
2013-01-01
Giardia duodenalis is a protozoan of public health interest that causes gastroenteritis in humans and other animals. In the city of Campinas in southeast Brazil, giardiasis is endemic, and this pathogen is detected at high concentrations in wastewater effluents, which are potential reservoirs for transmission. The Samambaia wastewater treatment plant (WWTP) in the city of Campinas employs an activated sludge system for sewage treatment and ultraviolet (UV) light for disinfection of effluents. To evaluate this disinfection process with respect to inactivating G. duodenalis cysts, two sample types were investigated: (i) effluent without UV disinfection (EFL) and (ii) effluent with UV disinfection (EFL+UV). Nude immunodeficient BALB/c mice were intragastrically inoculated with a mean dose of 14 cysts of G. duodenalis recovered from effluent from this WWTP, EFL, or EFL+UV. All animals inoculated with G. duodenalis cysts developed the infection, but animals inoculated with UV-exposed cysts released a lower average concentration of cysts in their faeces than animals inoculated with cysts that were not UV disinfected. Trophozoites were also observed in both groups of animals. These findings suggest that G. duodenalis cysts exposed to UV light were damaged but were still able to cause infection. PMID:27335858
Plewa, Michael J; Wagner, Elizabeth D; Metz, Deborah H; Kashinkunti, Ramesh; Jamriska, Katherine J; Meyer, Maria
2012-07-17
Alternative technologies to disinfect drinking water such as ultraviolet (UV) disinfection are becoming more widespread. The benefits of UV disinfection include reduced risk of microbial pathogens such as Cryptosporidium and reduced production of regulated drinking water disinfection byproducts (DBPs). The objective of this research was to determine if mammalian cell cytotoxicity and genotoxicity varied in response to different chlorination protocols with and without polychromatic medium pressure UV (MPUV) and monochromatic low pressure UV (LPUV) disinfection technologies. The specific aims were to analyze the mammalian cell cytotoxicity and genotoxicity of concentrated organic fractions from source water before and after chlorination and to determine the cytotoxicity and genotoxicity of the concentrated organic fractions from water samples treated with UV alone or UV before or after chlorination. Exposure of granular activated carbon-filtered Ohio River water to UV alone resulted in the lowest levels of mammalian cell cytotoxicity and genotoxicity. With combinations of UV and chlorine, the lowest levels of cytotoxicity and genotoxicity were observed with MPUV radiation. The best combined UV plus chlorine methodology that generated the lowest cytotoxicity and genotoxicity employed chlorination first followed by MPUV radiation. These data may prove important in the development of multibarrier methods of pathogen inactivation of drinking water, while limiting unintended toxic consequences.
Ultraviolet (UV) disinfection of grey water: particle size effects.
Winward, G P; Avery, L M; Stephenson, T; Jefferson, B
2008-02-01
The impact of water quality on the ultraviolet (UV) disinfection of grey water was investigated with reference to urban water reuse. Direct UV disinfection of grey water did not meet the stringent California State Title 22 criteria for unrestricted urban water reuse due to the presence of particulate material ranging from < 1 to > or = 2000 microm in size. Grey water was manipulated by settling to produce fractions of varying particle size distributions and blending was employed post-disinfection to extract particle-associated coliforms (PACs). The efficacy of UV disinfection was found to be linked to the particle size of the grey water fractions. The larger particle size fractions with a mean particle size of 262 microm and above were observed to shield more coliforms from UV light than did the smaller particles with a mean particle size below 119 microm. Up to 70% of total coliforms in the larger particle size fractions were particle-associated following a UV dose (fluence) of 260 mJ.cm(-2) and would remain undetected by standard coliform enumeration techniques. Implications for urban water reuse are discussed and recommendations made for grey water treatment to ensure removal of particle-associated indicator bacteria and pathogens prior to UV disinfection.
Murphy, H M; Payne, S J; Gagnon, G A
2008-04-01
This study was designed to examine the potential downstream benefits of sequential disinfection to control the persistence of Escherichia coli under conditions relevant to drinking water distribution systems. Eight annular reactors (four polycarbonate and four cast iron) were setup in parallel to address various factors that could influence biofilm growth in distribution systems. Eight reactors were treated with chlorine, chlorine dioxide and monochloramine alone or in combination with UV to examine the effects on Escherichia coli growth and persistence in both the effluent and biofilm. In general, UV-treated systems in combination with chlorine or chlorine dioxide and monochloramine achieved greater log reductions in both effluent and biofilm than systems treated with chlorine-based disinfectants alone. However, during UV-low chlorine disinfection, E. coli was found to persist at low levels, suggesting that the UV treatment had instigated an adaptive mutation. During UV-chlorine-dioxide treatment, the E. coli that was initially below the detection limit reappeared during a low level of disinfection (0.2 mg/L) in the cast iron systems. Chloramine was shown to be effective in disinfecting suspended E. coli in the effluent but was unable to reduce biofilm counts to below the detection limit. Issues such as repair mechanism of E. coli and nitrification could help explain some of these aberrations. Improved understanding of the ability of chlorine-based disinfectant in combination with UV to provide sufficient disinfection will ultimately effect in improved management and safety of drinking water.
Ibrahim, Mohamed A S; MacAdam, Jitka; Autin, Olivier; Jefferson, Bruce
2014-01-01
Ultraviolet (UV) technologies have been very successful in disinfection applications due to their ability to inactivate microorganisms without producing harmful disinfection by-products. However, there have been a number of concerns associated with the use of conventional UV systems such as hazardous mercury content, high capital investment and reduced electrical efficiency. These concerns have set limitations for the use of UV processes. The study evaluates the development of light emitting diode (LED) technology as an alternative UV source over the last 5 years, analyses the projections provided by the researchers and UV LED manufacturers and presents the information in a cost model with the aim to predict the timeline at which UV LED will compete with traditional UV low pressure high output technology in the commercial market at full-scale residential and industrial disinfection applications.
Lin, Tao; Cai, Bo; Chen, Wei
2014-11-01
In this study, we tested the potential of Limnoithona sinensis to provide its attached bacteria refuge against disinfection. The experimental results indicated that in water devoid of zooplankton, both UV radiation and chlorine disinfection significantly decreased the viability of free-living bacteria. In the presence of L. sinensis, however, the attached bacteria could survive and rapidly recover from disinfection. This demonstrated that L. sinensis provided protection from external damage to various aquatic bacteria that were attached to its body. The surviving bacteria remained on L. sinensis after disinfection exposure, which enabled a rapid increase in the bacterial population followed by their subsequent release into the surrounding water. Compared with UV radiation, chlorine disinfection was more effective in terms of inactivating attached bacteria. Both UV radiation and chlorine disinfection had little effect in terms of preventing the spread of undesirable bacteria, due to the incomplete inactivation of the bacteria associated with L. sinensis.
Role of Ultraviolet Disinfection in the Prevention of Surgical Site Infections.
Simmons, Sarah; Dale, Charles; Holt, James; Velasquez, Katie; Stibich, Mark
2017-01-01
The role of the environment in surgical site infections is surprisingly understudied. UV disinfection holds promise for reducing the level of contamination in operating rooms and thereby lowering the risk of infection for patients. Issues such as the frequency, amount and locations for UV disinfection to have an impact on the risk of surgical site infection are recently emerging in the literature. As technologies and knowledge improve, UV disinfection will have a role to play in operating rooms in the future.
Li, Guo-Qiang; Wang, Wen-Long; Huo, Zheng-Yang; Lu, Yun; Hu, Hong-Ying
2017-12-01
Studies on ultraviolet light-emitting diode (UV-LED) water disinfection have shown advantages, such as safety, flexible design, and lower starting voltages. However, information about reactivation after UV-LED disinfection is limited, which is an important issue of UV light-based technology. In this study, the photoreactivation and dark repair of Escherichia coli after UV-LEDs and low pressure (LP) UV disinfection were compared. Four UV-LED units, 265 nm, 280 nm, the combination of 265 + 280 (50%), and 265 + 280 (75%) were tested. 265 nm LEDs was more effective than 280 nm LEDs and LP UV lamps for E. coli inactivation. No synergic effect for disinfection was observed from the combination of 265 and 280 nm LEDs. 265 nm LEDs had no different reactivation performances with that of LP UV, while 280 nm LEDs could significantly repress photoreactivation and dark repair at a low irradiation intensity of 6.9 mJ/cm 2 . Furthermore, the UV-induced damage of 280 nm LEDs was less repaired which was determined by endonuclease sensitive site (ESS) assay. The impaired protein activities by 280 nm LEDs might be one of the reasons that inhibited reactivation. A new reactivation rate constant, K max , was introduced into the logistic model to simulate the reactivation data, which showed positive relationship with the maximum survival ratio and was more reasonable to interpret the results of photoreactivation and dark repair. This study revealed the distinct roles of different UV lights in disinfection and reactivation, which is helpful for the future design of UV-LED equipment. Copyright © 2017 Elsevier Ltd. All rights reserved.
Equivalency testing of ultraviolet disinfection for wastewater reclamation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oppenheimer, J.A.; Jacangelo, J.G.; Laine, J.M.
1996-11-01
UV light disinfection was shown to continuously provide microbial inactivation equivalent to chlorine while reducing the formation of known carcinogenic disinfection by-products and the formation of chronic whole effluent toxicity. This was the first study to demonstrate UV`s performance relative to chlorination over an extended timeframe at a full-scale facility treating to meet the most stringent California reclamation standards.
Verification testing of the SUNTEC LPX200 UV Disinfection System to develop the UV delivered dose flow relationship was conducted at the Parsippany-Troy Hills wastewater treatment plant test site in Parsippany, New Jersey. Two lamp modules were mounted parallel in a 6.5-meter lon...
CHALLENGES OF COMBINED SEWER OVERFLOW DISINFECTION BY ULTRAVIOLET LIGHT IRRADIATION
This article examines the performance and effectiveness of ultraviolet (UV) light irradiation for disinfection of combined sewer overflow (CSO). Due to the negative impact of conventional water disinfectants on aquatic life, new agents (e.g., UV light) are being investigated for ...
Lee, O-Mi; Kim, Hyun Young; Park, Wooshin; Kim, Tae-Hun; Yu, Seungho
2015-09-15
Ionizing radiation technology was suggested as an alternative method to disinfection processes, such as chlorine, UV, and ozone. Although many studies have demonstrated the effectiveness of irradiation technology for microbial disinfection, there has been a lack of information on comparison studies of disinfection techniques and a regrowth of each treatment. In the present study, an ionizing radiation was investigated to inactivate microorganisms and to determine the critical dose to prevent the regrowth. As a result, it was observed that the disinfection efficiency using ionizing radiation was not affected by the seasonal changes of wastewater characteristics, such as temperature and turbidity. In terms of bacterial regrowth after disinfection, the ionizing radiation showed a significant resistance of regrowth, whereas, on-site UV treatment is influenced by the suspended solid, temperature, or precipitation. The electric power consumption was also compared for the economic feasibility of each technique at a given value of disinfection efficiency of 90% (1-log), showing 0.12, 36.80, and 96.53 Wh/(L/day) for ionizing radiation, ozone, and UV, respectively. The ionizing radiation requires two or three orders of magnitude lower power consumption than UV and ozone. Consequently, ionizing radiation can be applied as an effective and economical alternative technique to other conventional disinfection processes. Copyright © 2015 Elsevier B.V. All rights reserved.
Ultraviolet disinfection of potable water
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wolfe, R.L.
Because of upcoming surface and groundwater regulations regarding the control of microbiological and chemical contaminants, there is a need to evaluate the feasibility and effectiveness of ultraviolet (UV) radiation for primary disinfection of potable water supplies. Data is presented on microbicidal wavelengths of UV and distribution of energy output for low and medium-pressure arc lamps. Both systems were found to perform equally well for inactivating microorganisms, but each had distinct advantages in different applications. Approximate dosages for 90% inactivation of selected microorganisms by UV is presented in a table. Cost analysis for disinfection is presented in two tables as wellmore » as the advantages and disadvantages of UV disinfection. 38 refs.« less
Garvey, Mary; Rowan, Neil
2015-06-01
The use of ultraviolet (UV) light for water disinfection has become increasingly popular due to on-going issues with drinking water and public health. Pulsed UV light has proved to be an effective form of inactivating a range of pathogens including parasite species. However, there are limited data available on the use of pulsed UV light for the disinfection of flowing water in the absence or presence of inorganic contaminants commonly found in water sources. Here, we report on the inactivation of test species including Bacillus endospores following pulsed UV treatment as a flow through system. Significant levels of inactivation were obtained for both retention times tested. The presence of inorganic contaminants iron and/or manganese did affect the rate of disinfection, predominantly resulting in an increase in the levels of inactivation at certain UV doses. The findings of this study suggest that pulsed UV light may provide a method of water disinfection as it successfully inactivated bacterial cells and bacterial endospores in the absence and presence of inorganic contaminants.
Paredes, L; Omil, F; Lema, J M; Carballa, M
2018-01-15
The phototransformation of 18 organic micropollutants (OMPs) commonly detected in wastewater treatment plant (WWTP) effluents was examined attempting to explain their fate during UV disinfection in WWTPs. For this purpose, a lab-scale UV reactor (lamp emitting at 254nm) was used to study the influence of the operational conditions (UV dose, temperature and water matrix) on OMPs abatement and disinfection efficiency. Chemical properties of OMPs and the quality of treated effluent were identified as key factors affecting the phototransformation rate of these compounds. Sampling campaigns were carried out at the inlet and outlet of UV systems of three WWTPs, and the results evidenced that only the most photosensitive compounds, such as sulfamethoxazole and diclofenac, are eliminated. Therefore, despite UV treatment is an effective technology to phototransform OMPs, the UV doses typically applied for disinfection (10-50mJ/cm 2 ) are not sufficient to remove them. Consequently, small modifications (increase of UV dose, use of catalysts) should be applied in WWTPs to enhance the abatement of OMPs in UV systems. Copyright © 2017 Elsevier B.V. All rights reserved.
ULTRAVIOLET LIGHT DISINFECTION OF COMBINED SEWER OVERFLOW (NEW ORLEANS)
The objective of this state-of-the-art review is to examine the performance and effectiveness of ultraviolet (UV) light disinfection for combined sewer overflow (CSO) applications. Topics presented include the use of UV light as a disinfecting agent, its practical applications, d...
Biswal, Basanta Kumar; Khairallah, Ramzi; Bibi, Kareem; Mazza, Alberto; Gehr, Ronald; Masson, Luke; Frigon, Dominic
2014-06-01
Wastewater discharges may increase the populations of pathogens, including Escherichia coli, and of antimicrobial-resistant strains in receiving waters. This study investigated the impact of UV and peracetic acid (PAA) disinfection on the prevalence of virulence and antimicrobial resistance genes in uropathogenic Escherichia coli (UPEC), the most abundant E. coli pathotype in municipal wastewaters. Laboratory disinfection experiments were conducted on wastewater treated by physicochemical, activated sludge, or biofiltration processes; 1,766 E. coli isolates were obtained for the evaluation. The target disinfection level was 200 CFU/100 ml, resulting in UV and PAA doses of 7 to 30 mJ/cm(2) and 0.9 to 2.0 mg/liter, respectively. The proportions of UPECs were reduced in all samples after disinfection, with an average reduction by UV of 55% (range, 22% to 80%) and by PAA of 52% (range, 11% to 100%). Analysis of urovirulence genes revealed that the decline in the UPEC populations was not associated with any particular virulence factor. A positive association was found between the occurrence of urovirulence and antimicrobial resistance genes (ARGs). However, the changes in the prevalence of ARGs in potential UPECs were different following disinfection, i.e., UV appears to have had no effect, while PAA significantly reduced the ARG levels. Thus, this study showed that both UV and PAA disinfections reduced the proportion of UPECs and that PAA disinfection also reduced the proportion of antimicrobial resistance gene-carrying UPEC pathotypes in municipal wastewaters.
Biswal, Basanta Kumar; Khairallah, Ramzi; Bibi, Kareem; Mazza, Alberto; Gehr, Ronald; Masson, Luke
2014-01-01
Wastewater discharges may increase the populations of pathogens, including Escherichia coli, and of antimicrobial-resistant strains in receiving waters. This study investigated the impact of UV and peracetic acid (PAA) disinfection on the prevalence of virulence and antimicrobial resistance genes in uropathogenic Escherichia coli (UPEC), the most abundant E. coli pathotype in municipal wastewaters. Laboratory disinfection experiments were conducted on wastewater treated by physicochemical, activated sludge, or biofiltration processes; 1,766 E. coli isolates were obtained for the evaluation. The target disinfection level was 200 CFU/100 ml, resulting in UV and PAA doses of 7 to 30 mJ/cm2 and 0.9 to 2.0 mg/liter, respectively. The proportions of UPECs were reduced in all samples after disinfection, with an average reduction by UV of 55% (range, 22% to 80%) and by PAA of 52% (range, 11% to 100%). Analysis of urovirulence genes revealed that the decline in the UPEC populations was not associated with any particular virulence factor. A positive association was found between the occurrence of urovirulence and antimicrobial resistance genes (ARGs). However, the changes in the prevalence of ARGs in potential UPECs were different following disinfection, i.e., UV appears to have had no effect, while PAA significantly reduced the ARG levels. Thus, this study showed that both UV and PAA disinfections reduced the proportion of UPECs and that PAA disinfection also reduced the proportion of antimicrobial resistance gene-carrying UPEC pathotypes in municipal wastewaters. PMID:24727265
The response of aggregated Pseudomonas putida CP1 cells to UV-C and UV-A/B disinfection.
Maganha de Almeida, Ana C; Quilty, Bríd
2016-11-01
UV radiation is a spread method used worldwide for the disinfection of water. However, much of the research on the disinfection of bacterial cells by UV has focused on planktonic cells. Many bacterial cells in nature are present in clumps or aggregates, and these aggregates, which are more resistant to disinfection than their planktonic counterparts, can be problematic in engineered water systems. The current research used Pseudomonas putida (P. putida) CP1, an environmental and non-pathogenic microorganism which autoaggregates when grown under certain conditions, as a model organism to simulate aggregated cells. The study investigated the response of both the planktonic and the aggregated forms of the bacterium to UV-C (λ = 253.7 nm) and UV-A/B (λ > 300 nm) disinfection at laboratory scale in a minimal medium. The planktonic cells of P. putida CP1 were inactivated within 60 s by UV-C and in 60 min by UV-A/B; however, the aggregated cells required 120 min of UV-C treatment and 240 min of UV-A/B radiation to become inactive. The size of the aggregate was reduced following UV treatment. Although all the cells had lost culturability, viability as measured by the LIVE/DEAD ® stain and epifluorescence microscopy was not completely lost and the cells all demonstrated regrowth after overnight incubation in the dark.
UV disinfection is an effective process for inactivating many microbial pathogens found in source waters with the potential as stand-alone treatment or in combination with other disinfectants. For surface and groundwater sourced drinking water applications, the U.S. Environmental...
UV DISINFECTION GUIDANCE MANUAL FOR THE ...
Provides technical information on selection, design and operation of UV systems; provides regulatory agencies with guidance and the necessary tools to assess UV systems at the design, start-up, and routine operation phase; provides manufacturers with the testing and performance standards for UV components and systems for treating drinking water. Provide guidance to water systems, regulators and manufacturers on UV disinfection of drinking water.
UV disinfection is an effective process for inactivating many microbial pathogens found in source waters with the potential as stand-alone treatment or in combination with other disinfectants. For surface and groundwater sourced drinking water applications, the U.S. Environmental...
Lyon, Bonnie A; Dotson, Aaron D; Linden, Karl G; Weinberg, Howard S
2012-10-01
Ultraviolet (UV) disinfection is being increasingly used in drinking water treatment. It is important to understand how its application to different types of water may influence finished water quality, particularly as anthropogenic activity continues to impact the quality of source waters. The objective of this study was to evaluate the effect of inorganic precursors on the formation of regulated and unregulated disinfection byproducts (DBPs) during UV irradiation of surface waters when combined with chlorination or chloramination. Samples were collected from three drinking water utilities supplied by source waters with varying organic and inorganic precursor content. The filtered samples were treated in the laboratory with a range of UV doses delivered from low pressure (LP, UV output at 253.7 nm) and medium pressure (MP, polychromatic UV output 200-400 nm) mercury lamps followed by chlorination or chloramination, in the presence and absence of additional bromide and nitrate. The regulated trihalomethanes and haloacetic acids were not affected by UV pretreatment at disinfection doses (40-186 mJ/cm²). With higher doses (1000 mJ/cm²), trihalomethane formation was increased 30-40%. While most effects on DBPs were only observed with doses much higher than typically used for UV disinfection, there were some effects on unregulated DBPs at lower doses. In nitrate-spiked samples (1-10 mg N/L), chloropicrin formation doubled and increased three- to six-fold with 40 mJ/cm² MP UV followed by chloramination and chlorination, respectively. Bromopicrin formation was increased in samples containing bromide (0.5-1 mg/L) and nitrate (1-10 mg N/L) when pretreated with LP or MP UV (30-60% with 40 mJ/cm² LP UV and four- to ten-fold increase with 40 mJ/cm² MP UV, after subsequent chlorination). The formation of cyanogen chloride doubled and increased three-fold with MP UV doses of 186 and 1000 mJ/cm², respectively, when followed by chloramination in nitrate-spiked samples but remained below the World Health Organization guideline value of 70 μg/L in all cases. MP UV and high LP UV doses (1000 mJ/cm²) increased chloral hydrate formation after subsequent chlorination (20-40% increase for 40 mJ/cm² MP UV). These results indicate the importance of bench-testing DBP implications of UV applications in combination with post-disinfectants as part of the engineering assessment of a UV-chlorine/chloramine multi-barrier disinfection design for drinking water treatment. Copyright © 2012 Elsevier Ltd. All rights reserved.
US EPA Testing of LP & MP UV Disinfection Technologies
Presentation will discuss the ongoing USEPA research on UV disinfection addressing the following objectives: Conservatively predict log inactivation and RED of adenovirus with surrogates; Conduct many (LP=61) UV reactor conditions challenged with Ad2, B. pumilus, and MS2 & conduc...
Rubio, D; Nebot, E; Casanueva, J F; Pulgarin, C
2013-10-15
Innovative disinfection technologies are being studied for seawater, seeking a viable alternative to chlorination. This study proposes the use of H2O2/UV254 and photo-Fenton as disinfection treatment in seawater. The irradiations were carried out using a sunlight simulator (Suntest) and a cylindrical UV reactor. The efficiency of the treatment was compared for Milli-Q water, Leman Lake water and artificial seawater. The presence of bicarbonates and organic matter was investigated in order to evaluate possible effects on the photo-Fenton disinfection treatment. The photo-Fenton treatment, employing 1 mg L(-1) Fe(2+) and 10 mg L(-1) of H2O2, led to the fastest bacterial inactivation kinetics. Using H2O2/UV254 high disinfection rates were obtained similar to those obtained with photo-Fenton under UV254 light. In Milli-Q water, the rate of inactivation for Escherichia coli was higher than in Leman Lake water and seawater due to the lack of inorganic ions affecting negatively bacteria inactivation. The presence of bicarbonate showed scavenging of the OH(•) radicals generated in the treatment of photo-Fenton and H2O2/UV254. Despite the negative effect of inorganic ions, especially HCO3(-), the disinfection treatments with AOPs in lake water and seawater improved significantly the disinfection compared to light alone (simulated sunlight and UV254). In the treatment of photo-Fenton with simulated sunlight, dissolved organic matter had a beneficial effect by increasing the rate of inactivation. This is associated with the formation of Fe(3+)-organo photosensitive complexes leading to the formation of ROS able to inactivate bacteria. This effect was not observed in the photo-Fenton with UV254. Growth of E. coli surviving in seawater was observed 24 and 48 h after treatment with UV light. However, growth of surviving bacteria was not detected after photo-Fenton with UV254 and H2O2/UV254 treatments. This study suggests H2O2/UV254 and photo-Fenton treatments for the disinfection of seawater, in spite its high concentration of salts. Copyright © 2013 Elsevier Ltd. All rights reserved.
Sequential and Simultaneous Applications of UV and Chlorine for Adenovirus Inactivation.
Rattanakul, Surapong; Oguma, Kumiko; Takizawa, Satoshi
2015-09-01
Adenoviruses are water-borne human pathogens with high resistance to UV disinfection. Combination of UV treatment and chlorination could be an effective approach to deal with adenoviruses. In this study, human adenovirus 5 (HAdV-5) was challenged in a bench-scale experiment by separate applications of UV or chlorine and by combined applications of UV and chlorine in either a sequential or simultaneous manner. The treated samples were then propagated in human lung carcinoma epithelial cells to quantify the log inactivation of HAdV-5. When the processes were separate, a fluence of 100 mJ/cm(2) and a CT value of 0.02 mg min/L were required to achieve 2 log inactivation of HAdV-5 by UV disinfection and chlorination, respectively. Interestingly, synergistic effects on the HAdV-5 inactivation rates were found in the sequential process of chlorine followed by UV (Cl2-UV) (p < 0.05, ANCOVA) in comparison to the separate processes or the simultaneous application of UV/Cl2. This implies that a pretreatment with chlorine may increase the sensitivity of the virus to the subsequent UV disinfection. In conclusion, this study suggests that the combined application of UV and chlorine could be an effective measure against adenoviruses as a multi-barrier approach in water disinfection.
Sultan, Tipu
2016-07-01
This article describes the assessment of a numerical procedure used to determine the UV lamp configuration and surface roughness effects on an open channel water disinfection UV reactor. The performance of the open channel water disinfection UV reactor was numerically analyzed on the basis of the performance indictor reduction equivalent dose (RED). The RED values were calculated as a function of the Reynolds number to monitor the performance. The flow through the open channel UV reactor was modelled using a k-ε model with scalable wall function, a discrete ordinate (DO) model for fluence rate calculation, a volume of fluid (VOF) model to locate the unknown free surface, a discrete phase model (DPM) to track the pathogen transport, and a modified law of the wall to incorporate the reactor wall roughness effects. The performance analysis was carried out using commercial CFD software (ANSYS Fluent 15.0). Four case studies were analyzed based on open channel UV reactor type (horizontal and vertical) and lamp configuration (parallel and staggered). The results show that lamp configuration can play an important role in the performance of an open channel water disinfection UV reactor. The effects of the reactor wall roughness were Reynolds number dependent. The proposed methodology is useful for performance optimization of an open channel water disinfection UV reactor. Copyright © 2016 Elsevier Ltd. All rights reserved.
Guo, Mei-Ting; Yuan, Qing-Bin; Yang, Jian
2013-10-15
Little is known about the microbial selectivity of UV treatment for antibiotic resistant bacteria, and the results of limited studies are conflicting. To understand the effect of UV disinfection on antibiotic resistant bacteria, both total heterotrophic bacteria and antibiotic resistant bacteria (including cephalexin-, ciprofloxacin-, erythromycin-, gentamicin-, vancomycin-, sulfadiazine-, rifampicin-, tetracycline- and chloramphenicol-resistant bacteria) were examined in secondary effluent samples from a municipal wastewater treatment plant. Bacteria resistant to both erythromycin and tetracycline were chosen as the representative of multiple-antibiotic-resistant bacteria and their characteristics after UV treatment were also investigated. UV disinfection results in effective inactivation for total heterotrophic bacteria, as well as all antibiotic resistant bacteria. After UV treatment at a fluence of 5 mJ/cm(2), the log reductions of nine types of antibiotic resistant bacteria varied from 1.0 ± 0.1 to 2.4 ± 0.1. Bacteria resistant to both erythromycin and tetracycline had a similar fluence response as did total heterotrophic bacteria. The findings suggest that UV disinfection could eliminate antibiotic resistance in wastewater treatment effluents and thus ensure public health security. Our experimental results indicated that UV disinfection led to enrichment of bacteria with resistance to sulfadiazine, vancomycin, rifampicin, tetracycline and chloramphenicol, while the proportions of cephalexin-, erythromycin-, gentamicin- and ciprofloxacin-resistant bacteria in the wastewater decreased. This reveals the microbial selectivity of UV disinfection for antibiotic resistant bacteria. Copyright © 2013 Elsevier Ltd. All rights reserved.
Calibration and characterization of UV sensors for water disinfection
NASA Astrophysics Data System (ADS)
Larason, T.; Ohno, Y.
2006-04-01
The National Institute of Standards and Technology (NIST), USA is participating in a project with the American Water Works Association Research Foundation (AwwaRF) to develop new guidelines for ultraviolet (UV) sensor characteristics to monitor the performance of UV water disinfection plants. The current UV water disinfection standards, ÖNORM M5873-1 and M5873-2 (Austria) and DVGW W294 3 (Germany), on the requirements for UV sensors for low-pressure mercury (LPM) and medium-pressure mercury (MPM) lamp systems have been studied. Additionally, the characteristics of various types of UV sensors from several different commercial vendors have been measured and analysed. This information will aid in the development of new guidelines to address issues such as sensor requirements, calibration methods, uncertainty and traceability. Practical problems were found in the calibration methods and evaluation of spectral responsivity requirements for sensors designed for MPM lamp systems. To solve the problems, NIST is proposing an alternative sensor calibration method for MPM lamp systems. A future calibration service is described for UV sensors intended for low- and medium-pressure mercury lamp systems used in water disinfection applications.
Zoeteman, B C; Hrubec, J; de Greef, E; Kool, H J
1982-01-01
A retrospective epidemiological study in The Netherlands showed a statistical association between chlorination by-products in drinking water and cancer of the esophagus and stomach for males. A pilot-plant study with alternative disinfectants was carried out with stored water of the Rivers Rhine and Meuse. It was demonstrated that the increase of direct acting mutagens after treatment with chlorine dioxide is similar to the effect of chlorination. Ozonation of Rhine water reduced the mutagenic activity for Salmonella typhimurium TA 98 both with and without metabolic activation. UV alone hardly affects the mutagenicity of the stored river water for S. typh. TA 98. In all studies, practically no mutagenic activity for S. typh. TA 100 was found. Although remarkable changes in the concentration of individual organic compounds are reported, the identity of the mutagens detected is yet unclear. Compounds of possible interest due to their removal by ozonation are 1,3,3-trimethyloxindole, dicyclopentadiene and several alkylquinolines. Compounds which might be responsible for the increased mutagenicity after chlorination are two brominated acetonitriles and tri(2-chlorethyl) phosphate. Furthermore, the concentration procedure with adsorption on XAD resin and the subsequent elution step may have affected the results. It is proposed to focus further research more on the less volatile by-products of disinfection than on the trihalomethanes. PMID:7151762
UV technology to inactivate Cryptosporidium parvum oocysts has become well established in the US. The challenge now is to effectively demonstrate UV reactor performance and disinfection capacity with various finished water matrices and under different operational conditions. In s...
NASA Astrophysics Data System (ADS)
Filiouguine, Igor V.; Kostiouchenko, S. V.; Koudryavtsev, N. N.; Vasilyak, Leonid M.; Yakimenko, A. V.
1993-11-01
The bacteriological disinfective action of UV-radiation is well known. The pioneer work on UV-radiation used for bacteriological disinfection of waste water was made in 1910. Because of the high cost and low living time of the UV-radiation sources, the alternative technique for waste water purification by chlorine introducing was spread out. During the second stage of the UV purification development, beginning in approximately 1970, the interest for bacteriological cleaning of water, increased again. Two reasons were responsible for this event: first, the significant improvement of technology and design of UV-bacteriological purificators, and second, recognition of the serious danger of chlorine compounds introduced into water under purification because of the toxicity of these compounds. Further investigations gave excellent results in the creation and industrial applications of UV- bacteriological purificators. Now we can see a rapid development of industrial technology in UV-purification of drinking and waste waters.
Verification testing of the Ondeo Degremont, Inc. Aquaray® 40 HO VLS Disinfection System to develop the UV delivered dose flow relationship was conducted at the Parsippany-Troy Hills wastewater treatment plant test site in Parsippany, New Jersey. Three reactor modules were m...
Cross-Resistance of UV- or Chlorine Dioxide-Resistant Echovirus 11 to Other Disinfectants
Zhong, Qingxia; Carratalà, Anna; Ossola, Rachele; Bachmann, Virginie; Kohn, Tamar
2017-01-01
The emergence of waterborne viruses with resistance to disinfection has been demonstrated in the laboratory and in the environment. Yet, the implications of such resistance for virus control remain obscure. In this study we investigate if viruses with resistance to a given disinfection method exhibit cross-resistance to other disinfectants. Chlorine dioxide (ClO2)- or UV-resistant populations of echovirus 11 were exposed to five inactivating treatments (free chlorine, ClO2, UV radiation, sunlight, and heat), and the extent of cross-resistance was determined. The ClO2-resistant population exhibited cross-resistance to free chlorine, but to none of the other inactivating treatments tested. We furthermore demonstrated that ClO2 and free chlorine act by a similar mechanism, in that they mainly inhibit the binding of echovirus 11 to its host cell. As such, viruses with host binding mechanisms that can withstand ClO2 treatment were also better able to withstand oxidation by free chlorine. Conversely, the UV-resistant population was not significantly cross-resistant to any other disinfection treatment. Overall, our results indicate that viruses with resistance to multiple disinfectants exist, but that they can be controlled by inactivating methods that operate by a distinctly different mechanism. We therefore suggest to utilize two disinfection barriers that act by different mechanisms in order to control disinfection-resistant viruses. PMID:29046672
Sirikanchana, Kwanrawee; Shisler, Joanna L.; Mariñas, Benito J.
2008-01-01
The mechanisms of adenovirus serotype 2 inactivation with either UV light (with a narrow emission spectrum centered at 254 nm) or monochloramine were investigated by assessing the potential inhibition of two key steps of the adenovirus life cycle, namely, E1A protein synthesis and viral genomic replication. E1A early protein synthesis was assayed by using immunoblotting, while the replication of viral DNA was analyzed by using slot blotting. Disinfection experiments were performed in phosphate buffer solutions at pH 8 and room temperature (UV) or 20°C (monochloramine). Experimental results revealed that normalized E1A levels at 12 h postinfection (p.i.) were statistically the same as the corresponding decrease in survival ratio for both UV and monochloramine disinfection. Normalized DNA levels at 24 h p.i. were also found to be statistically the same as the corresponding decrease in survival ratio for monochloramine disinfection. In contrast, for UV disinfection, genomic DNA levels were much lower than E1A or survival ratios, possibly as a result of a delay in DNA replication for UV-treated virions compared to that for controls. Future efforts will determine the pre-E1A synthesis step in the adenovirus life cycle affected by exposure to UV and monochloramine, with the goal of identifying the viral molecular target of these two disinfectants. PMID:18424543
Horikoshi, Satoshi; Tsuchida, Akihiro; Abe, Masahiko; Ohba, Naoki; Uchida, Masayoshi; Serpone, Nick
2010-01-01
This short article examines the microwave-assisted photolytic disinfection of aqueous solutions contaminated by Bacillus subtilis microorganisms using UV and vacuum-UV radiation emitted from a microwave discharge electrodeless lamp (MDEL), a device containing a Hg/Ar gas-fill that was proposed recently for use in Advanced Oxidation Processes (AOPs). Results of the disinfection are compared with those obtained from UV radiation emitted by a low-pressure electrode Hg lamp and by an excimer lamp. Also examined is the disinfection of B. subtilis aqueous media that contained Au3+ or Ni2+ ions, species often found in the treatment of electroplating wash wastewaters.
Treatment and potential reuse of greywater from schools: a pilot study.
Alsulaili, Abdalrahman D; Hamoda, Mohamed F; Al-Jarallah, Rawa; Alrukaibi, Duaij
2017-05-01
This study presented performance data on a low cost and easy maintenance pilot system for on-site treatment and reuse of water collected from wash sinks and fountains, as major sources of greywater (GW) at schools. Various treatment options were studied including screening, sand filtration, chlorination, and UV disinfection operated at different flow rates. Results showed that filtration operated at low rates is very effective in total suspended solids (TSS) removal, while UV proved to be more effective than chlorination for reduction of biochemical oxygen demand (BOD), chemical oxygen demand (COD), and total coliforms. Removal efficiencies up to 63%, 30% and 20% were obtained for TSS, COD and BOD, respectively and reductions of log TC (CFU/100 ml) from 6.5 to 2 were obtained at a filtration rate of 14 m 3 /d·m 2 . Treated effluent satisfied WHO standards for reclaimed water reuse in landscape irrigation and toilet flushing. The filtration-UV system is robust, showing the best and most reliable performance for low and high strength GW treatment even under a 10-fold increase in flow rate. A 5 m 3 /d pilot plant was developed for schools having 500 students and detailed cost-benefit analysis indicated a net saving value, a surplus of $1,600 per year, and pay back after 6 years and 11 months.
Xu, Limei; Zhang, Chongmiao; Xu, Pengcheng; Wang, Xiaochang C
2018-03-01
Traditional culture methods may underestimate the tolerance of microorganisms to disinfectants because of the existence of viable but nonculturable or sublethally injured cells after disinfection. The selection of a strict method is crucial for the evaluation of disinfection performance. The actions of 2 typical disinfectants - ultraviolet (UV) and chlorine - on the fecal indicator Escherichia coli were investigated by the detection of culturability, membrane permeability, metabolic activity, deoxyribonucleic acid (DNA), and messenger ribonucleic acid (mRNA). During UV disinfection, the irreversible damages in the cell membrane and cellular adenosine triphosphate (ATP) were negligible at low UV doses (<80mJ/cm 2 ). However, membrane permeability was damaged at low doses of chlorine (<5mg/L), leading to leakage of cellular ATP. Our study showed that a slight lesion in DNA was detected even at high doses of UV (400mJ/cm 2 ) and chlorine (>5mg/L) treatments. The decay of mRNA was more rapid than that of DNA. The degradation level of mRNA depended on the choice of target genes. After exposure to 50mJ/cm 2 UV dose or 5mg/L chlorine for 30min, the DNA damage repair function (RecA mRNA) was inhibited. The mRNA involved in the DNA damage repair function can be a potential indicator of bacterial viability. Copyright © 2017. Published by Elsevier B.V.
Mo, Weiwei; Cornejo, Pablo K; Malley, James P; Kane, Tyler E; Collins, M Robin
2018-06-20
Many of the small drinking water systems in the US that utilize simple filtration and chlorine disinfection or chlorine disinfection alone are facing disinfection byproduct (DBP) noncompliance issues, which need immediate upgrades. In this study, four potential upgrade scenarios, namely the GAC, ozone, UV30, and UV186 scenarios, were designed for a typical small drinking water systems and compared in terms of embodied energy, carbon footprint, and life cycle cost. These scenarios are designed to either reduce the amount of DBP precursors using granular activated carbon filtration (the GAC scenario) or ozonation (the ozone scenario), or replace the chlorine disinfection with the UV disinfection at different intensities followed by chloramination (the UV30 and UV186 scenarios). The UV30 scenario was found to have the lowest embodied energy (417 GJ/year) and life cycle cost ($0.25 million US dollars), while the GAC scenario has the lowest carbon footprint (21 Mg CO 2 e/year). The UV186 scenario consistently presents the highest environmental and economic impacts. The major contributors of the economic and environmental impacts of individual scenarios also differ. Energy and/or material consumptions during the operation phase dominate the environmental impacts of the four scenarios, while the infrastructure investments have a noticeable contribution to the economic costs. The results are sensitive to changes in water quality. An increase of raw water quality, i.e., an increase in organic precursor content, could potentially result in the ozone scenario being the least energy intensive scenario, while a decrease of water quality could greatly reduce the overall competitiveness of the GAC scenario. Copyright © 2018 Elsevier Ltd. All rights reserved.
Jenny, Richard M; Jasper, Micah N; Simmons, Otto D; Shatalov, Max; Ducoste, Joel J
2015-10-15
Alternative disinfection sources such as ultraviolet light (UV) are being pursued to inactivate pathogenic microorganisms such as Cryptosporidium and Giardia, while simultaneously reducing the risk of exposure to carcinogenic disinfection by-products (DBPs) in drinking water. UV-LEDs offer a UV disinfecting source that do not contain mercury, have the potential for long lifetimes, are robust, and have a high degree of design flexibility. However, the increased flexibility in design options will add a substantial level of complexity when developing a UV-LED reactor, particularly with regards to reactor shape, size, spatial orientation of light, and germicidal emission wavelength. Anticipating that LEDs are the future of UV disinfection, new methods are needed for designing such reactors. In this research study, the evaluation of a new design paradigm using a point-of-use UV-LED disinfection reactor has been performed. ModeFrontier, a numerical optimization platform, was coupled with COMSOL Multi-physics, a computational fluid dynamics (CFD) software package, to generate an optimized UV-LED continuous flow reactor. Three optimality conditions were considered: 1) single objective analysis minimizing input supply power while achieving at least (2.0) log10 inactivation of Escherichia coli ATCC 11229; and 2) two multi-objective analyses (one of which maximized the log10 inactivation of E. coli ATCC 11229 and minimized the supply power). All tests were completed at a flow rate of 109 mL/min and 92% UVT (measured at 254 nm). The numerical solution for the first objective was validated experimentally using biodosimetry. The optimal design predictions displayed good agreement with the experimental data and contained several non-intuitive features, particularly with the UV-LED spatial arrangement, where the lights were unevenly populated throughout the reactor. The optimal designs may not have been developed from experienced designers due to the increased degrees of freedom offered by using UV-LEDs. The results of this study revealed that the coupled optimization routine with CFD was effective at significantly decreasing the engineer's design decision space and finding a potentially near-optimal UV-LED reactor solution. Published by Elsevier Ltd.
Hong, Xuesen; Wen, Junjie; Xiong, Xuhua; Hu, Yongyou
2016-07-01
Novel silver nanowire (AgNW) - carbon fiber cloth (CC) nanocomposites were synthesized by a rapid and facile method. Acting as filter in an electrical gravity filtration device, the AgNW-CC nanocomposites were applied to electrochemical point-of-use water disinfection. AgNW-CC nanocomposites were characterized by FESEM, XRD, and FTIR. Their disinfection performance toward Escherichia coli and bacteriophage MS2 was evaluated by inhibition zone tests, optical density growth curve tests, and flow tests. The results showed that complex 3D AgNW networks with controllable silver release (<100 ppb) were fabricated on CC by using UV curing adhesive. AgNW-CC nanocomposites exhibited excellent intrinsic antibacterial activities against E. coli. The concentration of AgNWs and UV adhesive controlled the released silver and hence led to the change in antibacterial activity. The external electric field significantly enhanced the disinfection efficiency of AgNW-CC nanocomposites. Over 99.999% removal of E. coli and MS2 could be achieved. More complex AgNW networks contributed to higher disinfection efficiency under 10 V and 10(6) CFU (PFU) mL(-1) of microorganism. UV adhesive could keep the disinfection performance from being affected by flow rate. The convenient synthesis and outstanding disinfection performance offer AgNW-CC nanocomposites opportunities in the application of electrochemical point-of-use drinking water disinfection. Copyright © 2016 Elsevier Ltd. All rights reserved.
Human adenovirus is relatively resistant to UV radiation and has been used as a conservative testing microbe for evaluations of UV disinfection systems as components of water treatment processes. In this study, we attempted to validate the applicability of integrated cell culture...
An EPR study on wastewater disinfection by peracetic acid, hydrogen peroxide and UV irradiation.
Bianchini, Roberto; Calucci, Lucia; Caretti, Cecilia; Lubello, Claudio; Pinzino, Calogero; Piscicelli, Michela
2002-09-01
EPR spectroscopy was applied to obtain qualitative and quantitative information on the radicals produced in disinfection processes of wastewater for agricultural reuse. The DEPMPO spin trap was employed to detect hydroxyl and carbon-centered short living radicals in two different peracetic acid solutions and a hydrogen peroxide solution used for water disinfection either in the absence or in the presence of UV-C irradiation. Moreover, three different kinds of water (wastewater, demineralized water, distilled water) were analysed in order to assess the contribution of Fenton reactions to the radical production. The spectroscopic results were discussed in relation to the efficiency of the different oxidizing agents and UV irradiation in wastewater disinfection evaluated as Escherichia Coli, Faecal and Total Coliforms inactivation.
Beal, A; Mahida, N; Staniforth, K; Vaughan, N; Clarke, M; Boswell, T
2016-06-01
There is growing interest in the use of no-touch automated room decontamination devices within healthcare settings. Xenex PX-UV is an automated room disinfection device using pulsed ultraviolet (UV) C radiation with a short cycle time. To investigate the microbiological efficacy of this device when deployed for terminal decontamination of isolation rooms within a clinical haematology unit. The device was deployed in isolation rooms in a clinical haematology unit. Contact plates were applied to common touch points to determine aerobic total colony counts (TCCs) and samples collected using Polywipe™ sponges for detection of vancomycin-resistant enterococci (VRE). The device was easy to transport, easy to use, and it disinfected rooms rapidly. There was a 76% reduction in the TCCs following manual cleaning, with an additional 14% reduction following UV disinfection, resulting in an overall reduction of 90% in TCCs. There was a 38% reduction in the number of sites where VRE was detected, from 26 of 80 sites following manual cleaning to 16 of 80 sites with additional UV disinfection. The Xenex PX-UV device can offer a simple and rapid additional decontamination step for terminal disinfection of patient rooms. However, the microbiological efficacy against VRE was somewhat limited. Copyright © 2016 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Understanding possible underlying mechanism in declining germicidal efficiency of UV-LED reactor.
Lee, Hyunkyung; Jin, Yongxun; Hong, Seungkwan
2018-06-07
Since ultraviolet light emitting diodes (UV-LEDs) have emerged as an alternative light source for UV disinfection systems, enhancement of reactor performance is a demanding challenge to promote its practical application in water treatment process. This study explored the underlying mechanism of the inefficiency observed in flow-through mode UV disinfection tests to improve the light utilization of UV-LED applications. In particular, the disinfection performance of UV-LED reactors was evaluated using two different flow channel types, reservoir and pathway systems, in order to elucidate the impact of physical circumstances on germicidal efficiency as the light profile was adjusted. Overall, a significant reduction in germicidal efficiency was observed when exposure time was prolonged or a mixing chamber was integrated. Zeta analysis revealed that the repulsion rate between microorganisms decreased with UV fluence transfer, and that change might cause the shielding effect of UV delivery to target microorganisms. In line with the above findings, the reduction in efficiency intensified when opportunities for microbial collision increased. Thus, UV induced microbial aggregation was implicated as being a disinfection hindering factor, exerting its effect through uneven UV illumination. Ultimately, the results refuted the prevailing belief that UV has a cumulative effect. We found that the reservoir system achieved worse performance than the pathway system despite it providing 15 times higher UV fluence: the differences in germicidal efficiency were 1-log, 1.4-log and 1.7-log in the cases of P.aeruginosa, E.coli and S.aureus, respectively. Copyright © 2018 Elsevier B.V. All rights reserved.
Weber, David J; Kanamori, Hajime; Rutala, William A
2016-08-01
This article reviews 'no touch' methods for disinfection of the contaminated surface environment of hospitalized patients' rooms. The focus is on studies that assessed the effectiveness of ultraviolet (UV) light devices, hydrogen peroxide systems, and self-disinfecting surfaces to reduce healthcare-associated infections (HAIs). The contaminated surface environment in hospitals plays an important role in the transmission of several key nosocomial pathogens including methicillin-resistant Staphylococcus aureus, vancomycin-resistant Enterococcus spp., Clostridium difficile, Acinetobacter spp., and norovirus. Multiple clinical trials have now demonstrated the effectiveness of UV light devices and hydrogen peroxide systems to reduce HAIs. A limited number of studies have suggested that 'self-disinfecting' surfaces may also decrease HAIs. Many studies have demonstrated that terminal cleaning and disinfection with germicides is often inadequate and leaves environmental surfaces contaminated with important nosocomial pathogens. 'No touch' methods of room decontamination (i.e., UV devices and hydrogen peroxide systems) have been demonstrated to reduce key nosocomial pathogens on inoculated test surfaces and on environmental surfaces in actual patient rooms. Further UV devices and hydrogen peroxide systems have been demonstrated to reduce HAI. A validated 'no touch' device or system should be used for terminal room disinfection following discharge of patients on contact precautions. The use of a 'self-disinfecting' surface to reduce HAI has not been convincingly demonstrated.
Haider, Thomas; Sommer, Regina; Knasmüller, Siefried; Eckl, Peter; Pribil, Walter; Cabaj, Alexander; Kundi, Michael
2002-01-01
Ground water samples from different geographic areas in Austria, with different amounts of natural and anthropogenic organic compounds were treated with a standardized low pressure UV (254 nm)-irradiation laboratory flow-through system (UV fluence: 800 J/m2). The genotoxic activities of the water samples before and after the UV disinfection were investigated using a combination of three different bioassays which complement each other with regard to their sensitivity detecting different genotoxins. The test battery comprises the Salmonella/microsome assay (Ames test with TA98. TA 100 and TA 102, with and without S9 mix) and two micronucleus tests with the plant Tradescantia (clone #4430) and with primary rat hepatocytes. Overall, the tested Austrian groundwater samples used for human consumption caused only weak genotoxic activities compared to drinking water samples reported from other countries under similar experimental conditions. With the exception of one weak positive result in the Ames test (only in strain TA98 without S9 mix) with an induction factor of 1.9) all samples after UV disinfection were devoid of additional mutagenic and clastogenic activities compared to the samples before UV disinfection.
Shirai, A; Watanabe, T; Matsuki, H
2017-02-01
The low energy of UV-A (315-400 nm) is insufficient for disinfection. To improve UV-A disinfection technology, we evaluated the effect of ferulic acid (FA) addition on disinfection by UV-A light-emitting diode (LED) (350-385 nm) against various food spoilers and pathogens (seven bacteria and four fungi species). Photoantimicrobial assays were performed at FA concentrations below the MIC. The MIC of the isomerized FA, consisting of 93% cis-form and 7% trans-form, was very similar to that of the commercially available FA (trans-form). Irradiation with UV-A (1·0 J cm -2 ) in the presence of 100 mg l -1 FA resulted in enhanced reducing of all of the tested bacterial strains. A combination of UV-A (10 J cm -2 ) and 1000 mg l -1 FA resulted in enhanced reducing of Saccharomyces cerevisiae and one of the tested filamentous fungi. These results demonstrated that the combination of a short-term application of UV-A and FA at a low concentration yielded synergistic enhancement of antimicrobial activity, especially against bacteria. Microbial contamination is one of the most serious problems for foods, fruit and sugar thick juices. UV light is suitable for the nonthermal decontamination of food products by inactivating the contaminating micro-organisms. However, UV-A exposure is insufficient for disinfection. This study demonstrates that the combination of UV-A LED light (350-385 nm), which is not hazardous to human eyes and skin, and ferulic acid (FA), a known phytochemical and food additive, provides synergistic antimicrobial activity against foodborne pathogenic and spoilage micro-organisms. Therefore, FA addition to UV-A light treatment may be useful for improvement of UV-A disinfection technology to prevent food deterioration. © 2016 The Society for Applied Microbiology.
Zakaria, Fiona; Harelimana, Bertin; Ćurko, Josip; van de Vossenberg, Jack; Garcia, Hector A; Hooijmans, Christine Maria; Brdjanovic, Damir
2016-01-01
Ultraviolet germicidal (short wavelength UV-C) light was studied as surface disinfectant in an Emergency Sanitation Operation System(®) smart toilet to aid to the work of manual cleaning. The UV-C light was installed and regulated as a self-cleaning feature of the toilet, which automatically irradiate after each toilet use. Two experimental phases were conducted i.e. preparatory phase consists of tests under laboratory conditions and field testing phase. The laboratory UV test indicated that irradiation for 10 min with medium-low intensity of 0.15-0.4 W/m(2) could achieve 6.5 log removal of Escherichia coli. Field testing of the toilet under real usage found that UV-C irradiation was capable to inactivate total coliform at toilet surfaces within 167-cm distance from the UV-C lamp (UV-C dose between 1.88 and 2.74 mW). UV-C irradiation is most effective with the support of effective manual cleaning. Application of UV-C for surface disinfection in emergency toilets could potentially reduce public health risks.
UV Disinfection System for Cabin Air
NASA Astrophysics Data System (ADS)
Lim, Soojung
Ultraviolet (UV) radiation is commonly used for disinfection of water. As a result of advancements made in the last 10-15 years, the analysis and design of UV disinfection systems for water is well developed. UV disinfection is also used for disinfection of air; however, despite the fact the UV-air systems have a longer record of application than UV-water systems, the methods used to analyze and design UV-air disinfection systems remain quite empirical. It is well-established that the effectiveness of UV-air systems is strongly affected by the type of microorganisms, the irradiation level/type (lamp power and wavelength), duration of irradiation (exposure time), air movement pattern (mixing degree), and relative humidity. This paper will describe ongoing efforts to evaluate, design and test a UV-air system based on first principles. Specific issues to be addressed in this work will include laboratory measurements of relevant kinetics (i.e., UV dose-response behavior) and numerical simulations designed to represent fluid mechanics and the radiation intensity field. UV dose-response behavior of test microorganism was measured using a laboratory (bench-scale) system. Target microorganisms (e.g., bacterial spores) were first applied to membrane filters at sub-monolayer coverage. The filters were then transferred to an environmental chamber at fixed relative humidity (RH) and allowed to equilibrate with their surroundings. Microorganisms were then subjected to UV exposure under a collimated beam. The experiment was repeated at RH values ranging from 20% to 100%. UV dose-response behavior was observed to vary with RH. For example, at 100% RH, a UV dose of 20 mJ/cm2 accomplished 90% (1 log10 units) of the B. subtilis spore inactivation, whereas 99 % (2 log10 units) inactivation was accomplished at this same UV dose under 20% RH conditions. However, at higher doses, the result was opposite of that in low dose. Reactor behavior is simulated using an integrated application of computational fluid dynamics (CFD) and radiation intensity field models. These simulations followed a Lagrangian approach, wherein the UV radiation intensity field was mapped onto simulated particle trajectories for prediction of the UV dose delivered to each particle. By repeating these calculations for a large number of simulated particle trajectories, an estimate of the UV dose distribution delivered by the reactor can be made. In turn, these dose distribution estimates are integrated with the UV dose-response behavior described above to yield an estimate of microbial inactivation accomplished by the reactor. This modeling approach has the advantage of allowing simulation of many reactor configurations in a relatively short period of time. Moreover, by following this approach of "numerical prototyping," it is possible to "build" and analyze several virtual reactors before the construction of a physical prototype. As such, this procedure allows effective development of efficient reactors.
da Costa, Juliana Berninger; Rodgher, Suzelei; Daniel, Luiz Antonio; Espíndola, Evaldo Luiz Gaeta
2014-11-01
The toxic potential of four disinfectant agents (chlorine, ozone, peracetic acid and UV radiation), used in the disinfection of urban wastewater, was evaluated with respect to four aquatic organisms. Disinfection assays were carried out with wastewater from the city of Araraquara (São Paulo State, Brazil), and subsequently, toxicity bioassays were applied in order to verify possible adverse effects to the cladocerans (Ceriodaphnia silvestrii and Daphnia similis), midge larvae Chironomus xanthus and fish (Danio rerio). Under the experimental conditions tested, all the disinfectants were capable of producing harmful effects on the test organisms, except for C. xanthus. The toxicity of the effluent to C. silvestrii was observed to increase significantly as a result of disinfection using 2.5 mg L(-1) chlorine and 29.9 mg L(-1) ozone. Ozonation and chlorination significantly affected the survival of D. similis and D. rerio, causing mortality of 60 to 100 % in comparison to the non-disinfected effluent. In experiments with effluent treated with peracetic acid (PAA) and UV radiation, a statistically significant decrease in survival was only detected for D. rerio. This investigation suggested that the study of the ideal concentrations of disinfectants is a research need for ecologically safe options for the treatment of wastewater.
Huang, Jing-Jing; Tang, Fang; Xi, Jin-Ying; Pang, Yu-Chen; Hu, Hong-Ying
2014-04-01
Prevalence of antibiotic-resistant bacteria in wastewater effluents is concerned as an emerging contaminant. To estimate inactivation and reactivation potentials of antibiotic-resistant bacteria by UV disinfection, inactivation and reactivation of penicillin-, ampicillin-, cephalexin-, chloramphenicol-and rifampicin-resistant bacteria in the secondary effluent were studied under different UV doses. The results showed that the inactivation ratios of penicillin-, ampicillin-, cephalexin-and chloramphenicol-resistant bacteria were higher than 4-log, which was closed to that of total heterotrophic bacteria; however, the inactivation ratio of rifampicin-resistant bacteria was lower (3.7-log) under 20 mJ x cm(-2) UV exposure. After 22 h standing incubation, antibiotic-resistant bacteria widely reactivated. The colony forming ability of antibiotic-resistant bacteria was as high as 3-log when exposed to 20 mJ x cm(-2) UV light. Hence, conventional UV dose can not effectively control reactivation of antibiotic-resistant bacteria in reclaimed water by UV disinfection.
Ali, S; Yui, S; Muzslay, M; Wilson, A P R
2017-10-01
Ultraviolet (UV) light decontamination systems are being used increasingly to supplement terminal disinfection of patient rooms. However, efficacy may not be consistent in the presence of soil, especially against Clostridium difficile spores. To demonstrate in-use efficacy of two whole-room UV decontamination systems against three hospital pathogens with and without soil. For each system, six patient rooms were decontaminated with UV irradiation (enhanced disinfection) following manual terminal cleaning. Total aerobic colony counts of surface contamination were determined by spot-sampling 15 environmental sites before and after terminal disinfection and after UV irradiation. Efficacy against biological indicator coupons (stainless-steel discs) was performed for each system using test bacteria (10 6 cfu EMRSA-15 variant A, carbapenemase-producing Klebsiella pneumoniae) or spores (10 5 cfu C. difficile 027), incorporating low soiling [0.03% bovine serum albumin (BSA)], heavy soiling (10% BSA) or synthetic faeces (C. difficile only) placed at five locations in the room. UV disinfection eliminated contamination after terminal cleaning in 8/14 (57%) and 11/14 (79%) sites. Both systems demonstrated 4-5 log 10 reductions in meticillin-resistant Staphylococcus aureus and K. pneumoniae at low soiling. Lower and more variable log 10 reductions were achieved when heavy soiling was present. Between 0.1 and 4.8 log 10 reductions in C. difficile spores were achieved with low but not heavy soil challenge. Terminal disinfection should be performed on all surfaces prior to UV decontamination. In-house validation studies should be considered to ensure optimal positioning in each room layout and sufficient cycle duration to eliminate target pathogens. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Point-of-use water disinfection using ultraviolet and visible light-emitting diodes.
Lui, Gough Yumu; Roser, David; Corkish, Richard; Ashbolt, Nicholas J; Stuetz, Richard
2016-05-15
Improvements in point-of-use (POU) drinking water disinfection technologies for remote and regional communities are urgently needed. Conceptually, UV-C light-emitting diodes (LEDs) overcome many drawbacks of low-pressure mercury tube based UV devices, and UV-A or visible light LEDs also show potential. To realistically evaluate the promise of LED disinfection, our study assessed the performance of a model 1.3 L reactor, similar in size to solar disinfection bottles. In all, 12 different commercial or semi-commercial LED arrays (270-740 nm) were compared for their ability to inactivate Escherichia coli K12 ATCC W3110 and Enterococcus faecalis ATCC 19433 over 6h. Five log10 and greater reductions were consistently achieved using the 270, 365, 385 and 405 nm arrays. The output of the 310 nm array was insufficient for useful disinfection while 430 and 455 nm performance was marginal (≈ 4.2 and 2.3-log10s E. coli and E. faecalis over the 6h). No significant disinfection was observed with the 525, 590, 623, 660 and 740 nm arrays. Delays in log-phase inactivation of E. coli were observed, particularly with UV-A wavelengths. The radiation doses required for >3-log10 reduction of E. coli and E. faecalis differed by 10 fold at 270 nm but only 1.5-2.5 fold at 365-455 nm. Action spectra, consistent with the literature, were observed with both indicators. The design process revealed cost and technical constraints pertaining to LED electrical efficiency, availability and lifetime. We concluded that POU LED disinfection using existing LED technology is already technically possible. UV-C LEDs offer speed and energy demand advantages, while UV-A/violet units are safer. Both approaches still require further costing and engineering development. Our study provides data needed for such work. Copyright © 2016 Elsevier B.V. All rights reserved.
Ghantoji, Shashank S.; Stibich, Mark; Stachowiak, Julie; Cantu, Sherry; Adachi, Javier A.; Raad, Issam I.
2015-01-01
The standard for Clostridium difficile surface decontamination is bleach solution at a concentration of 10 % of sodium hypochlorite. Pulsed xenon UV light (PX-UV) is a means of quickly producing germicidal UV that has been shown to be effective in reducing environmental contamination by C. difficile spores. The purpose of this study was to investigate whether PX-UV was equivalent to bleach for decontamination of surfaces in C. difficile infection isolation rooms. High-touch surfaces in rooms previously occupied by C. difficile infected patients were sampled after discharge but before and after cleaning using either bleach or non-bleach cleaning followed by 15 min of PX-UV treatment. A total of 298 samples were collected by using a moistened wipe specifically designed for the removal of spores. Prior to disinfection, the mean contamination level was 2.39 c.f.u. for bleach rooms and 22.97 for UV rooms. After disinfection, the mean level of contamination for bleach was 0.71 c.f.u. (P = 0.1380), and 1.19 c.f.u. (P = 0.0017) for PX-UV disinfected rooms. The difference in final contamination levels between the two cleaning protocols was not significantly different (P = 0.9838). PX-UV disinfection appears to be at least equivalent to bleach in the ability to decrease environmental contamination with C. difficile spores. Larger studies are needed to validate this conclusion. PMID:25627208
NASA Technical Reports Server (NTRS)
Birmele, Michele N.; O'Neal, Jeremy A.; Roberts, Michael S.
2011-01-01
Ultraviolet (UV) light has long been used in terrestrial water treatment systems for photodisinfection and the removal of organic compounds by several processes including photoadsorption, photolysis, and photocatalytic oxidation/reduction. Despite its effectiveness for water treatment, UV has not been explored for spacecraft applications because of concerns about the safety and reliability of mercury-containing UV lamps. However, recent advances in ultraviolet light emitting diodes (UV LEDs) have enabled the utilization of nanomaterials that possess the appropriate optical properties for the manufacture of LEDs capable of producing monochromatic light at germicidal wavelengths. This report describes the testing of a commercial-off-the-shelf, high power Nichia UV-A LED (250mW A365nnJ for the excitation of titanium dioxide as a point-of-use (POD) disinfection device in a potable water system. The combination of an immobilized, high surface area photocatalyst with a UV-A LED is promising for potable water system disinfection since toxic chemicals and resupply requirements are reduced. No additional consumables like chemical biocides, absorption columns, or filters are required to disinfect and/or remove potentially toxic disinfectants from the potable water prior to use. Experiments were conducted in a static test stand consisting of a polypropylene microtiter plate containing 3mm glass balls coated with titanium dioxide. Wells filled with water were exposed to ultraviolet light from an actively-cooled UV-A LED positioned above each well and inoculated with six individual challenge microorganisms recovered from the International Space Station (ISS): Burkholderia cepacia, Cupriavidus metallidurans, Methylobacterium fujisawaense, Pseudomonas aeruginosa, Sphingomonas paucimobilis and Wautersia basilensis. Exposure to the Nichia UV-A LED with photocatalytic oxidation resulted in a complete (>7-log) reduction of each challenge bacteria population in <180 minutes of contact time. With continued advances in the design and manufacture of UV-A LEDs and semi-conducting photocatalysts, LED activated photochemical process technology promises to extend its application to spacecraft environmental systems.
Spectral irradiance measurement and actinic radiometer calibration for UV water disinfection
NASA Astrophysics Data System (ADS)
Sperfeld, Peter; Barton, Bettina; Pape, Sven; Towara, Anna-Lena; Eggers, Jutta; Hopfenmüller, Gabriel
2014-12-01
In a joint project, sglux and PTB investigated and developed methods and equipment to measure the spectral and weighted irradiance of high-efficiency UV-C emitters used in water disinfection plants. A calibration facility was set up to calibrate the microbicidal irradiance responsivity of actinic radiometers with respect to the weighted spectral irradiance of specially selected low-pressure mercury and medium-pressure mercury UV lamps. To verify the calibration method and to perform on-site tests, spectral measurements were carried out directly at water disinfection plants in operation. The weighted microbicidal irradiance of the plants was calculated and compared to the measurements of various actinic radiometers.
Azimi, Y; Liu, Y; Tan, T C; Allen, D G; Farnood, R R
2017-12-01
The effects of floc structural characteristics, i.e. shape and dense biomass distribution, were evaluated on ultraviolet (UV) disinfection resistance, represented by the tailing level of the UV dose response curve (DRC). Ellipsoid-shaped flocs of similar volume and different projected circularities were constructed in-silico and a mathematical model was developed to compare their UV DRC tailing levels (indicative of UV-resistance). It was found that floc shape can significantly influence tailing level, and rounder flocs (i.e. flocs with higher circularity) were more UV-resistant. This result was confirmed experimentally by obtaining UV DRCs of two 75-90 μm floc populations with different percentages (20% vs. 30%) of flocs with circularities higher than 0.5. The population enriched in less circular flocs (i.e. 20% flocs with circularities >0.5) had a lower tailing level (at least by 1-log) compared to the other population. The second model was developed to describe variations in UV disinfection kinetics observed in flocs with transverse vs. radial biomass non-homogeneity, indicative of biofilm-originated vs. suspended flocs. The varied-density hemispheres model and shell-core model were developed to simulate transverse and radial non-homogeneity, respectively. The UV DRCs were mathematically constructed and biofilm-originated flocs showed higher UV resistance compared to suspended flocs. The calculated UV DRCs agreed well with the experimental data collected from activated sludge and trickling filter flocs (no fitting parameters were used). These findings provide useful information in terms of designing/modifying upstream processes for reducing UV disinfection energy demand. Copyright © 2017 Elsevier Ltd. All rights reserved.
Non-PRASA Drinking Water Research on UV Disinfection in Puerto Rico
The U.S. EPA and InterAmerican University of San German worked with water treatment operators from Patillas, Puerto Rico on the installation, training and testing of pretreatment/UV disinfection systems in the communities of La Sofia and Apeadero. This presentation provides path...
Mphaphlele, Matsie; Dharmadhikari, Ashwin S; Jensen, Paul A; Rudnick, Stephen N; van Reenen, Tobias H; Pagano, Marcello A; Leuschner, Wilhelm; Sears, Tim A; Milonova, Sonya P; van der Walt, Martie; Stoltz, Anton C; Weyer, Karin; Nardell, Edward A
2015-08-15
Transmission is driving the global tuberculosis epidemic, especially in congregate settings. Worldwide, natural ventilation is the most common means of air disinfection, but it is inherently unreliable and of limited use in cold climates. Upper room germicidal ultraviolet (UV) air disinfection with air mixing has been shown to be highly effective, but improved evidence-based dosing guidelines are needed. To test the efficacy of upper room germicidal air disinfection with air mixing to reduce tuberculosis transmission under real hospital conditions, and to define the application parameters responsible as a basis for proposed new dosing guidelines. Over an exposure period of 7 months, 90 guinea pigs breathed only untreated exhaust ward air, and another 90 guinea pigs breathed only air from the same six-bed tuberculosis ward on alternate days when upper room germicidal air disinfection was turned on throughout the ward. The tuberculin skin test conversion rates (>6 mm) of the two chambers were compared. The hazard ratio for guinea pigs in the control chamber converting their skin test to positive was 4.9 (95% confidence interval, 2.8-8.6), with an efficacy of approximately 80%. Upper room germicidal UV air disinfection with air mixing was highly effective in reducing tuberculosis transmission under hospital conditions. These data support using either a total fixture output (rather than electrical or UV lamp wattage) of 15-20 mW/m(3) total room volume, or an average whole-room UV irradiance (fluence rate) of 5-7 μW/cm(2), calculated by a lighting computer-assisted design program modified for UV use.
Nitrosamines in pilot-scale and full-scale wastewater treatment plants with ozonation.
Gerrity, Daniel; Pisarenko, Aleksey N; Marti, Erica; Trenholm, Rebecca A; Gerringer, Fred; Reungoat, Julien; Dickenson, Eric
2015-04-01
Ozone-based treatment trains offer a sustainable option for potable reuse applications, but nitrosamine formation during ozonation poses a challenge for municipalities seeking to avoid reverse osmosis and high-dose ultraviolet (UV) irradiation. Six nitrosamines were monitored in full-scale and pilot-scale wastewater treatment trains. The primary focus was on eight treatment trains employing ozonation of secondary or tertiary wastewater effluents, but two treatment trains with chlorination or UV disinfection of tertiary wastewater effluent and another with full advanced treatment (i.e., reverse osmosis and advanced oxidation) were also included for comparison. N-nitrosodimethylamine (NDMA) and N-nitrosomorpholine (NMOR) were the most prevalent nitrosamines in untreated (up to 89 ng/L and 67 ng/L, respectively) and treated wastewater. N-nitrosomethylethylamine (NMEA) and N-nitrosodiethylamine (NDEA) were detected at one facility each, while N-nitrosodipropylamine (NDPrA) and N-nitrosodibutylamine (NDBA) were less than their method reporting limits (MRLs) in all samples. Ozone-induced NDMA formation ranging from <10 to 143 ng/L was observed at all but one site, but the reasons for the variation in formation remain unclear. Activated sludge, biological activated carbon (BAC), and UV photolysis were effective for NDMA mitigation. NMOR was also removed with activated sludge but did not form during ozonation. Copyright © 2014 Elsevier Ltd. All rights reserved.
UV disinfection for reuse applications in North America.
Sakamoto, G; Schwartzel, D; Tomowich, D
2001-01-01
In an effort to conserve and protect limited water resources, the States of Florida and California have actively promoted wastewater reclamation and have implemented comprehensive regulations covering a range of reuse applications. Florida has a semi-tropical climate with heavy summer rains that are lost due to run off and evaporation. Much of California is arid and suffers periodic droughts, low annual rainfall and depleted ground water supplies. The high population density combined with heavy irrigation demands has depleted ground water supplies resulting in salt-water intrusion. During the past decade, Florida reuse sites have increased dramatically from 118 to 444 plants representing a total flow capacity of 826 MGD. California presently has over 250 plants producing 1 BGD with a projected increase of 160 sites over the next 20 years. To prevent the transmission of waterborne diseases, disinfection of reclaimed water is controlled by stringent regulations. Many states regulate wastewater treatment processes, nutrient removal, final effluent quality and disinfection criteria based upon the specific reuse application. As a rule, the resulting effluents have low turbidity and suspended solids. For such effluents, UV technology can economically achieve the most stringent disinfection targets that are required by the States of California and Florida for restricted and unrestricted reuse. This paper compares UV disinfection for wastewater reuse sites in California and Florida and discusses the effect of effluent quality on UV disinfection.
Anderson, Deverick J; Chen, Luke F; Weber, David J; Moehring, Rebekah W; Lewis, Sarah S; Triplett, Patricia F; Blocker, Michael; Becherer, Paul; Schwab, J Conrad; Knelson, Lauren P; Lokhnygina, Yuliya; Rutala, William A; Kanamori, Hajime; Gergen, Maria F; Sexton, Daniel J
2017-02-25
Patients admitted to hospital can acquire multidrug-resistant organisms and Clostridium difficile from inadequately disinfected environmental surfaces. We determined the effect of three enhanced strategies for terminal room disinfection (disinfection of a room between occupying patients) on acquisition and infection due to meticillin-resistant Staphylococcus aureus, vancomycin-resistant enterococci, C difficile, and multidrug-resistant Acinetobacter. We did a pragmatic, cluster-randomised, crossover trial at nine hospitals in the southeastern USA. Rooms from which a patient with infection or colonisation with a target organism was discharged were terminally disinfected with one of four strategies: reference (quaternary ammonium disinfectant except for C difficile, for which bleach was used); UV (quaternary ammonium disinfectant and disinfecting ultraviolet [UV-C] light except for C difficile, for which bleach and UV-C were used); bleach; and bleach and UV-C. The next patient admitted to the targeted room was considered exposed. Every strategy was used at each hospital in four consecutive 7-month periods. We randomly assigned the sequence of strategies for each hospital (1:1:1:1). The primary outcomes were the incidence of infection or colonisation with all target organisms among exposed patients and the incidence of C difficile infection among exposed patients in the intention-to-treat population. This trial is registered with ClinicalTrials.gov, NCT01579370. 31 226 patients were exposed; 21 395 (69%) met all inclusion criteria, including 4916 in the reference group, 5178 in the UV group, 5438 in the bleach group, and 5863 in the bleach and UV group. 115 patients had the primary outcome during 22 426 exposure days in the reference group (51·3 per 10 000 exposure days). The incidence of target organisms among exposed patients was significantly lower after adding UV to standard cleaning strategies (n=76; 33·9 cases per 10 000 exposure days; relative risk [RR] 0·70, 95% CI 0·50-0·98; p=0·036). The primary outcome was not statistically lower with bleach (n=101; 41·6 cases per 10 000 exposure days; RR 0·85, 95% CI 0·69-1·04; p=0·116), or bleach and UV (n=131; 45·6 cases per 10 000 exposure days; RR 0·91, 95% CI 0·76-1·09; p=0·303) among exposed patients. Similarly, the incidence of C difficile infection among exposed patients was not changed after adding UV to cleaning with bleach (n=38 vs 36; 30·4 cases vs 31·6 cases per 10 000 exposure days; RR 1·0, 95% CI 0·57-1·75; p=0·997). A contaminated health-care environment is an important source for acquisition of pathogens; enhanced terminal room disinfection decreases this risk. US Centers for Disease Control and Prevention. Copyright © 2017 Elsevier Ltd. All rights reserved.
Anderson, Deverick J; Chen, Luke F; Weber, David J; Moehring, Rebekah W; Lewis, Sarah S; Triplett, Patricia F; Blocker, Michael; Becherer, Paul; Schwab, J Conrad; Knelson, Lauren P; Lokhnygina, Yuliya; Rutala, William A; Kanamori, Hajime; Gergen, Maria F; Sexton, Daniel J
2018-01-01
Summary Background Patients admitted to hospital can acquire multidrug-resistant organisms and Clostridium difficile from inadequately disinfected environmental surfaces. We determined the effect of three enhanced strategies for terminal room disinfection (disinfection of a room between occupying patients) on acquisition and infection due to meticillin-resistant Staphylococcus aureus, vancomycin-resistant enterococci, C difficile, and multidrug-resistant Acinetobacter. Methods We did a pragmatic, cluster-randomised, crossover trial at nine hospitals in the southeastern USA. Rooms from which a patient with infection or colonisation with a target organism was discharged were terminally disinfected with one of four strategies: reference (quaternary ammonium disinfectant except for C difficile, for which bleach was used); UV (quaternary ammonium disinfectant and disinfecting ultraviolet [UV-C] light except for C difficile, for which bleach and UV-C were used); bleach; and bleach and UV-C. The next patient admitted to the targeted room was considered exposed. Every strategy was used at each hospital in four consecutive 7-month periods. We randomly assigned the sequence of strategies for each hospital (1:1:1:1). The primary outcomes were the incidence of infection or colonisation with all target organisms among exposed patients and the incidence of C difficile infection among exposed patients in the intention-to-treat population. This trial is registered with ClinicalTrials.gov, NCT01579370. Findings 31 226 patients were exposed; 21 395 (69%) met all inclusion criteria, including 4916 in the reference group, 5178 in the UV group, 5438 in the bleach group, and 5863 in the bleach and UV group. 115 patients had the primary outcome during 22 426 exposure days in the reference group (51·3 per 10 000 exposure days). The incidence of target organisms among exposed patients was significantly lower after adding UV to standard cleaning strategies (n=76; 33·9 cases per 10 000 exposure days; relative risk [RR] 0·70, 95% CI 0·50–0·98; p=0·036). The primary outcome was not statistically lower with bleach (n=101; 41·6 cases per 10 000 exposure days; RR 0·85, 95% CI 0·69–1·04; p=0·116), or bleach and UV (n=131; 45·6 cases per 10 000 exposure days; RR 0·91, 95% CI 0·76–1·09; p=0·303) among exposed patients. Similarly, the incidence of C difficile infection among exposed patients was not changed after adding UV to cleaning with bleach (n=38 vs 36; 30·4 cases vs 31·6 cases per 10 000 exposure days; RR 1·0, 95% CI 0·57–1·75; p=0·997). Interpretation A contaminated health-care environment is an important source for acquisition of pathogens; enhanced terminal room disinfection decreases this risk. Funding US Centers for Disease Control and Prevention. PMID:28104287
Treatment of Arctic wastewater by chemical coagulation, UV and peracetic acid disinfection.
Chhetri, Ravi Kumar; Klupsch, Ewa; Andersen, Henrik Rasmus; Jensen, Pernille Erland
2017-02-16
Conventional wastewater treatment is challenging in the Arctic region due to the cold climate and scattered population. Thus, no wastewater treatment plant exists in Greenland, and raw wastewater is discharged directly to nearby waterbodies without treatment. We investigated the efficiency of physicochemical wastewater treatment, in Kangerlussuaq, Greenland. Raw wastewater from Kangerlussuaq was treated by chemical coagulation and UV disinfection. By applying 7.5 mg Al/L polyaluminium chloride (PAX XL100), 73% of turbidity and 28% phosphate was removed from raw wastewater. E. coli and Enterococcus were removed by 4 and 2.5 log, respectively, when UV irradiation of 0.70 kWh/m 3 was applied to coagulated wastewater. Furthermore, coagulated raw wastewater in Denmark, which has a chemical quality similar to Greenlandic wastewater, was disinfected by peracetic acid or UV irradiation. Removal of heterotrophic bacteria by applying 6 and 12 mg/L peracetic acid was 2.8 and 3.1 log, respectively. Similarly, removal of heterotrophic bacteria by applying 0.21 and 2.10 kWh/m 3 for UV irradiation was 2.1 and greater than 4 log, respectively. Physicochemical treatment of raw wastewater followed by UV irradiation and/or peracetic acid disinfection showed the potential for treatment of arctic wastewater.
Penno, Katie; Jandarov, Roman A; Sopirala, Madhuri M
2017-11-01
We studied the effectiveness of an ultraviolet C (UV-C) emitter in clinical settings and compared it with observed terminal disinfection. We cultured 22 hospital discharge rooms at a tertiary care academic medical center. Phase 1 (unobserved terminal disinfection) included cultures of 11 high-touch environmental surfaces (HTSs) after terminal room disinfection (AD) and after the use of a UV-C-emitting device (AUV). Phase 2 (observed terminal disinfection) included cultures before terminal room disinfection (BD), AD, and AUV. Zero-inflated Poisson regression compared mean colony forming units (CFU) between the groups. Two-sample proportion tests identified significance of the observed differences in proportions of thoroughly cleaned HTSs (CFU < 5). Significant P value was determined using the Bonferroni corrected threshold of α = .05/12 = .004. We obtained 594 samples. Risk of overall contamination was 0.48 times lower in the AUV group than in the AD group (P < .001), with 1.04 log 10 reduction. During phase 1, overall proportion of HTSs with <5 CFUs increased in AUV versus AD by 0.12 (P = .001). During phase 2, it increased in AD versus BD by 0.45 (P < .001), with no significant difference between AD and AUV (P = .02). Use of UV-C with standard cleaning significantly reduced microbial burden and improved the thoroughness of terminal disinfection. We found no further benefit to UV-C use if standard terminal disinfection was observed. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Zhuang, Yao; Ren, Hongqiang; Geng, Jinju; Zhang, Yingying; Zhang, Yan; Ding, Lili; Xu, Ke
2015-05-01
This study investigated the inactivation of two antibiotic resistance genes (ARGs)-sul1 and tetG, and the integrase gene of class 1 integrons-intI1 by chlorination, ultraviolet (UV), and ozonation disinfection. Inactivation of sul1, tetG, and intI1 underwent increased doses of three disinfectors, and chlorine disinfection achieved more inactivation of ARGs and intI1 genes (chlorine dose of 160 mg/L with contact time of 120 min for 2.98-3.24 log reductions of ARGs) than UV irradiation (UV dose of 12,477 mJ/cm(2) for 2.48-2.74 log reductions of ARGs) and ozonation disinfection (ozonation dose of 177.6 mg/L for 1.68-2.55 log reductions of ARGs). The 16S rDNA was more efficiently removed than ARGs by ozone disinfection. The relative abundance of selected genes (normalized to 16S rDNA) increased during ozonation and with low doses of UV and chlorine disinfection. Inactivation of sul1 and tetG showed strong positive correlations with the inactivation of intI1 genes (for sul1, R (2) = 0.929 with p < 0.01; for tetG, R (2) = 0.885 with p < 0.01). Compared to other technologies (ultraviolet disinfection, ozonation disinfection, Fenton oxidation, and coagulation), chlorination is an alternative method to remove ARGs from wastewater effluents. At a chlorine dose of 40 mg/L with 60 min contact time, the selected genes inactivation efficiency could reach 1.65-2.28 log, and the cost was estimated at 0.041 yuan/m(3).
Weng, ShihChi; Dunkin, Nathan; Schwab, Kellogg J; McQuarrie, James; Bell, Kati; Jacangelo, Joseph G
2018-09-01
Peracetic acid (PAA) is a strong oxidant/bactericide that has been applied in various industries (e.g., food processing, pharmaceuticals, medical device sterilization, etc.) as a disinfectant. There is increasing interest in using PAA for wastewater disinfection because it does not form halogenated byproducts, and no post-treatment quenching is required. Previous studies have demonstrated good efficiency in controlling bacteria in wastewater, but limited information is available for viruses, especially those hosted by mammals (e.g., norovirus). Therefore, a study on the infectivity reduction of murine norovirus (MNV) was undertaken to evaluate the disinfection efficacy of PAA or UV alone and in combination with UV irradiation in undisinfected secondary effluent from a municipal wastewater reclamation facility (MWW) and phosphate buffer solution (PBS) at pH 7. Experiments employing MS2 bacteriophage were also performed in parallel for comparison purposes. MS2 infectivity reduction was found to be lower than MNV infectivity reduction for each condition studied - PAA, PAA + UV, and UV disinfection. These data suggest that MS2 may not be an appropriate surrogate to accurately predict the reduction of MNV infectivity. UV irradiation, in a dose range of 5-250 mJ/cm 2 , provided linear log inactivation (-log (N/N 0 )) with a regression slope (cm 2 mJ -1 ) of 0.031-0.034 and 0.165-0.202 for MS2 and MNV, respectively. UV irradiation provided similar inactivation for MS2 and MNV in both suspensions (PBS or MWW). Low infectivity reduction of MS2 was observed when PAA was used alone at a practical dose of 1.5 mg/L and below. A greater reduction of both MNV and MS2 was observed in PAA disinfection experiments using PBS as the microbial suspension medium, than in secondary effluent. Similar results were observed in PAA + UV experiments, in which greater synergistic effects were found in PBS than in MWW. Results of OH radical formation experiments suggest the presence of radical scavengers in MWW, which resulted in less opportunity for MNV and MS2 to encounter OHradicals. This study also demonstrated that the type of water can have a substantial impact on wastewater disinfection when employing PAA or PAA + UV treatment due to the matrix effect and the presence of radical scavengers, respectively. The results from this study could be employed to aid in the conceptual design of PAA and UV disinfection facilities, especially when norovirus is the organism of concern. Copyright © 2018. Published by Elsevier Ltd.
Potable Water Quality Management Guidance Document
2007-09-01
with alternative disinfectants and/or oxidants that form fewer disinfection byproducts than chlorine, such as chloramines , UV, ozone and chlorine...Alternative Disinfection Strategies............................................................................ 37 5.2.5.1. Chloramines ... disinfectant contact time” ( T ) in minutes, i.e., “C” x “ T ”. If a public water system applies disinfectants at more than one point prior to the first customer
Disinfection of iceberg lettuce by titanium dioxide-UV photocatalytic reaction.
Kim, Youngbong; Choi, Yoonjung; Kim, Soohyun; Park, Jonghyun; Chung, Myongsoo; Song, Kyung Bin; Hwang, Ingyun; Kwon, Kisung; Park, Jiyong
2009-09-01
Securing the physical quality and microbial safety of fresh foods has been a major focus in the food industry. To improve quality and increase the shelf life of fresh produce, disinfection methods have been developed. Titanium dioxide (TiO2) photocatalytic reactions under UV radiation produce hydroxyl radicals that can be used for disinfection of foodborne pathogenic bacteria. We investigated the effects of TiO2-UV photocatalytic disinfection on the shelf life of iceberg lettuce. Counts of natural microflora (total aerobic bacteria, coliforms, psychrotrophic bacteria, and yeasts and molds) and inoculated pathogenic bacteria (Escherichia coli, Listeria monocytogenes, Staphylococcus aureus, and Salmonella Typhimurium) on iceberg lettuce were determined after 20-min treatments with TiO2-UV, UV radiation, a sodium hypochlorite (NaOCl) solution, and tap water. TiO2-UV treatment reduced the number of microorganisms by 1.8 to 2.8 log CFU/g compared with reductions of 0.9 to 1.4 and 0.7 to 1.1 log CFU/g obtained with UV radiation and NaOCl treatments, respectively. Treatment with tap water was used as a control and resulted in no reductions. Counts of microflora for iceberg lettuce at 4 and 25 degrees C were determined during a 9-day period. TiO2-UV treatment resulted in 1.2- and 4.3-log increases in the counts of total aerobic bacteria at 4 and 25 degrees C, respectively, compared with 1.3- to 1.6-log and 4.4- to 4.8-log increases due to UV radiation and NaOCl treatments.
Effects of wastewater disinfection on waterborne bacteria and viruses
Blatchley, E. R.; Gong, W.-L.; Alleman, J.E.; Rose, J.B.; Huffman, D.E.; Otaki, M.; Lisle, J.T.
2007-01-01
Wastewater disinfection is practiced with the goal of reducing risks of human exposure to pathogenic microorganisms. In most circumstances, the efficacy of a wastewater disinfection process is regulated and monitored based on measurements of the responses of indicator bacteria. However, inactivation of indicator bacteria does not guarantee an acceptable degree of inactivation among other waterborne microorganisms (e.g., microbial pathogens). Undisinfected effluent samples from several municipal wastewater treatment facilities were collected for analysis. Facilities were selected to provide a broad spectrum of effluent quality, particularly as related to nitrogenous compounds. Samples were subjected to bench-scale chlorination and dechlorination and UV irradiation under conditions that allowed compliance with relevant discharge regulations and such that disinfectant exposures could be accurately quantified. Disinfected samples were subjected to a battery of assays to assess the immediate and long-term effects of wastewater disinfection on waterborne bacteria and viruses. In general, (viable) bacterial populations showed an immediate decline as a result of disinfectant exposure; however, incubation of disinfected samples under conditions that were designed to mimic the conditions in a receiving stream resulted in substantial recovery of the total bacterial community. The bacterial groups that are commonly used as indicators do not provide an accurate representation of the response of the bacterial community to disinfectant exposure and subsequent recovery in the environment. UV irradiation and chlorination/dechlorination both accomplished measurable inactivation of indigenous phage; however, the extent of inactivation was fairly modest under the conditions of disinfection used in this study. UV irradiation was consistently more effective as a virucide than chlorination/dechlorination under the conditions of application, based on measurements of virus (phage) diversity and concentration. Taken together, and when considered in conjunction with previously published research, the results of these experiments illustrate several important limitations of common disinfection processes as applied in the treatment of municipal wastewaters. In general, it is not clear that conventional disinfection processes, as commonly implemented, are effective for control of the risks of disease transmission, particularly those associated with viral pathogens. Microbial quality in receiving streams may not be substantially improved by the application of these disinfection processes; under some circumstances, an argument can be made that disinfection may actually yield a decrease in effluent and receiving water quality. Decisions regarding the need for effluent disinfection must account for site-specific characteristics, but it is not clear that disinfection of municipal wastewater effluents is necessary or beneficial for all facilities. When direct human contact or ingestion of municipal wastewater effluents is likely, disinfection may be necessary. Under these circumstances, UV irradiation appears to be superior to chlorination in terms of microbial quality and chemistry and toxicology. This advantage is particularly evident in effluents that contain appreciable quantities of ammonia-nitrogen or organic nitrogen.
Ultraviolet Light Emitting Diode Use in Advanced Oxidation Processes
2014-03-27
or medium pressure mercury lamps , but UV light emitting diodes ( LEDs ) have the capacity to be used for water disinfection also. Traditional mercury...based upon the phosphors that are selected and used to coat the inside of the glass tube from which these lamps are produced. A UV LED is...Research has demonstrated the ability to use UV LEDs in place of mercury lamps to achieve the same 7 disinfection capacity, and limited research has
HIGH-RATE DISINFECTION TECHNIQUES FOR COMBIND SEWER OVERFLOW
This paper presents high-rate disinfection technologies for combined sewer overflow (CSO). The high-rate disinfection technologies of interest are: chlorination/dechlorination, ultraviolet light irradiation (UV), chlorine dioxide (ClO2 ), ozone (O3), peracetic acid (CH3COOOH )...
NASA Astrophysics Data System (ADS)
Lizotte, Todd
2010-08-01
Recent events concerning H1N1 "swine flu", have demonstrated to the world the significant potential of rapid increases in death and illness among all age groups and even among the healthy population [1] when a highly infectious influenza virus is introduced. In terms of mass casualties due to a pandemic, preparedness and response planning must be done. One course of action to prevent a pandemic outbreak or reduce the impact of a bioterrorist event is the use of isolation or quarantine facilities. The first level of isolation or quarantine is within the personal residence of the person exposed or infected. In the case where, the specific virus is extremely contagious and its onset of symptoms is rapid and severe, there will be a need for the deployment and setup of larger self contained quarantine facilities. Such facilities are used to house infectious individuals to minimize the exposure of susceptible individuals to contagious individuals, especially when specialized care or treatment is required and during the viral shedding period (5 to 7 days). These types of facilities require non-shared air conditioning, heating and ventilating systems where 100% of air is vented to the outside through a series of disinfection systems and staged filters. Although chemical disinfection is possible, there is a desire to incorporate intense UV radiation as a means to deactivate and disinfect airborne virus within hospital settings and isolated mass scale quarantine facilities. UV radiation is also being considered for disinfection of contaminated surfaces, such as table tops, walls and floors in hospitals and temporary quarantine facilities. In such applications the use of UV bulb technology can create many problems, for instance bulb technology requires numerous bulbs to treat a large volume of air, generates significant heat, uses significant power and does not produce large fluxes of UV light efficiently. This paper provides several methods of creating quarantine level disinfection systems using high intensity UV laser sources instead of UV bulb techniques by using laser beam shaping optics in conjunction with traditional optical laser beam delivery techniques.
Zhang, Jie; Liu, Jing; He, Chuan-Shu; Qian, Chen; Mu, Yang
2018-06-04
Ultraviolet/hydrogen peroxide (UV/H 2 O 2 ) pre-oxidation has the potential to induce reactions with dissolved organic matter (DOM) and alter the generation of disinfection byproducts (DBPs). This study evaluated the influence of UV/H 2 O 2 pretreatment on the formation of iodo-trihalomethanes (I-THMs) during disinfection with chlorine or chloramine. The changes of precursors, I - and Br - , after UV/H 2 O 2 pretreatment were investigated, and then, the formation and speciation of I-THMs during chlorination or chloramination after pre-oxidation were explored. Additionally, the effects of UV doses and H 2 O 2 concentrations on the formation and speciation of I-THMs were studied. It was found that UV/H 2 O 2 pretreatment could change larger molecular weight (MW) DOM to smaller MW species, which had less aromatic organic compounds and fluorescence substances. Additionally, insignificant transformations of I - and Br - were observed after UV/H 2 O 2 treatment. Compared to direct disinfection, UV/H 2 O 2 pretreatment resulted in 23.0 ± 3.5% reduction in I-THMs formation during post-chlorination while an enhancement was observed during post-chloramination at a UV dose of 460 mJ/cm 2 and 20 mg/L H 2 O 2 . Moreover, total I-THM concentration increased from 43.7 ± 2.4 to 97.6 ± 14.9 nM with the increase of UV doses from 0 to 1400 mJ/cm 2 during the post-chlorination process, while reduced when the UV fluence was >460 mJ/cm 2 during the post-chloramination. Additionally, the generation of I-THMs during both post-chlorination and post-chloramination was positively related to the H 2 O 2 levels from 0 to 20 mg/L in the UV/H 2 O 2 pretreatment. Copyright © 2018 Elsevier B.V. All rights reserved.
Modern technologies for improving cleaning and disinfection of environmental surfaces in hospitals.
Boyce, John M
2016-01-01
Experts agree that careful cleaning and disinfection of environmental surfaces are essential elements of effective infection prevention programs. However, traditional manual cleaning and disinfection practices in hospitals are often suboptimal. This is often due in part to a variety of personnel issues that many Environmental Services departments encounter. Failure to follow manufacturer's recommendations for disinfectant use and lack of antimicrobial activity of some disinfectants against healthcare-associated pathogens may also affect the efficacy of disinfection practices. Improved hydrogen peroxide-based liquid surface disinfectants and a combination product containing peracetic acid and hydrogen peroxide are effective alternatives to disinfectants currently in widespread use, and electrolyzed water (hypochlorous acid) and cold atmospheric pressure plasma show potential for use in hospitals. Creating "self-disinfecting" surfaces by coating medical equipment with metals such as copper or silver, or applying liquid compounds that have persistent antimicrobial activity surfaces are additional strategies that require further investigation. Newer "no-touch" (automated) decontamination technologies include aerosol and vaporized hydrogen peroxide, mobile devices that emit continuous ultraviolet (UV-C) light, a pulsed-xenon UV light system, and use of high-intensity narrow-spectrum (405 nm) light. These "no-touch" technologies have been shown to reduce bacterial contamination of surfaces. A micro-condensation hydrogen peroxide system has been associated in multiple studies with reductions in healthcare-associated colonization or infection, while there is more limited evidence of infection reduction by the pulsed-xenon system. A recently completed prospective, randomized controlled trial of continuous UV-C light should help determine the extent to which this technology can reduce healthcare-associated colonization and infections. In conclusion, continued efforts to improve traditional manual disinfection of surfaces are needed. In addition, Environmental Services departments should consider the use of newer disinfectants and no-touch decontamination technologies to improve disinfection of surfaces in healthcare.
USDA-ARS?s Scientific Manuscript database
The effect of UV exposure on Toxoplasma gondii oocysts has not been completely defined for use in water disinfection. This study evaluated irradiated oocysts by three assays: a SCID mouse biassay, an in vitro T. gondii oocyst plaque assay (TOP-assay), and a quantitative reverse-transcriptase real-t...
2015-11-20
The Food and Drug Administration (FDA or the Agency) is classifying the ultraviolet (UV) radiation chamber disinfection device into class II (special controls). The special controls that will apply to the device are identified in this order and will be part of the codified language for the UV radiation chamber disinfection device classification. The Agency is classifying the device into class II (special controls) in order to provide a reasonable assurance of safety and effectiveness of the device.
Toxicity evaluation of surface water treated with different disinfectants in HepG2 cells.
Marabini, Laura; Frigerio, Silvia; Chiesara, Enzo; Radice, Sonia
2006-01-01
It is well known that water disinfection through chlorination causes the formation of a mixture of disinfection by-products (DBPs), many of which are genotoxic and carcinogenic. To demonstrate the formation of such compounds, a pilot water plant supplied with water from Lake Trasimeno was set up at the waterworks of Castiglione del Lago (PG, Italy). The disinfectants, continuously added to pre-filtered lake water flowing into three different basins, were sodium hypochlorite, chlorine dioxide and peracetic acid, an alternative disinfectant used until now for disinfecting waste waters, but not yet studied for a possible use in drinking water treatment. The aim of this study was to evaluate the formation during the disinfection processes of some toxic compounds that could explain the genotoxic effects of drinking waters. Differently treated waters were concentrated by solid-phase adsorption on silica C(18) columns and toxicity was assessed in a line of human hepatoma cells (HepG2), a metabolically competent cellular line very useful for human risk evaluation. The seasonal variability of the physical-chemical water characteristics (AOX, UV 254 nm, potential formation of THM, pH and temperature) made indispensable experimentation with water samples taken during the various seasons. Autumn waters cause greater toxicity compared to those of other seasons, in particular dilution of the concentrate at 0.5l equivalent of disinfected waters with chlorine dioxide and peracetic acid causes a 55% reduction in cellular vitality while the cellular vitality is over 80% with the all other water concentrates. Moreover it is very interesting underline that non-cytotoxic quantities of the autumnal water concentrates cause, after 2h treatment, a decrease in GSH and a statistically significant increase in oxygen radicals, while after prolonged treatment (24h) cause a GSH increase, without variations in the oxygen radical content. This phenomenon could be interpreted as the cellular adaptation response to an initial oxidative stress.
Sewage disinfection towards protection of drinking water resources.
Kolch, A
2000-01-01
Wastewater applied in agriculture for irrigation could replace the use of natural drinking-water resources. With respect to high concentrations of human pathogens wastewater has to be disinfected prior to use. This paper introduces disinfection methods with emphasis on UV irradiation.
Evaluation of an Innovative Approach to Validation of ...
UV disinfection is an effective process for inactivating many microbial pathogens found in source waters with the potential as stand-alone treatment or in combination with other disinfectants. For surface and groundwater sourced drinking water applications, the U.S. Environmental Protection Agency (USEPA) provided guidance on the validation of UV reactors nearly a decade ago. The focus of the guidance was primarily for inactivation of Cryptosporidium and Giardia. Over the last ten years many lessons have been learned, validation practices have been modified, new science issues discovered, and changes in operation & monitoring of UV systems need to be addressed. Also, there remains no standard approach for validating UV reactors to meet a 4-log (99.99%) inactivation of viruses. USEPA in partnership with the Cadmus Group, Carollo Engineers, and other State & Industry collaborators, are evaluating new approaches for validating UV reactors to meet groundwater & surface water pathogen inactivation including viruses for low-pressure and medium-pressure UV systems. A particular challenge for medium-pressure UV is the monitoring of low-wavelength germicidal contributions for appropriate crediting of disinfection under varying reactor conditions of quartz sleeve fouling, lamp aging, and changes in UV absorbance of the water over time. In the current effort, bench and full-scale studies are being conducted on a low pressure (LP) UV reactor and a medium pressure (MP) UV re
High-Rate Disinfection Techniques for Combined Sewer Overflow (Proceedings Paper)
This paper presents high-rate disinfection technologies for combined sewer overflow (CSO). The high-rate disinfection technologies of interest are: chlorination/dechlorination, ultraviolet light irradiation (UV), chlorine dioxide (ClO2 ), ozone (O3), peracetic acid (CH3COOOH ), a...
DEVELOPMENT OF A RATIONALLY BASED DESIGN PROTOCOL FOR THE ULTRAVIOLET LIGHT DISINFECTION PROCESS
A protocol is demonstrated for the design and evaluation of ultraviolet (UV) disinfection systems based on a mathematical model. The disinfection model incorporates the system's physical dimensions, the residence time distribution of the reactor and dispersion characteristics, th...
Peracetic acid (PAA) disinfection of primary, secondary and tertiary treated municipal wastewaters.
Koivunen, J; Heinonen-Tanski, H
2005-11-01
The efficiency of peracetic acid (PAA) disinfection against enteric bacteria and viruses in municipal wastewaters was studied in pilot-scale. Disinfection pilot-plant was fed with the primary or secondary effluent of Kuopio municipal wastewater treatment plant or tertiary effluent from the pilot-scale dissolved air flotation (DAF) unit. Disinfectant doses ranged from 2 to 7 mg/l PAA in the secondary and tertiary effluents, and from 5 to 15 mg/l PAA in the primary effluents. Disinfection contact times were 4-27 min. Disinfection of secondary and tertiary effluents with 2-7 mg/l PAA and 27 min contact time achieved around 3 log reductions of total coliforms (TC) and enterococci (EC). PAA disinfection also significantly improved the hygienic quality of the primary effluents: 10-15 mg/l PAA achieved 3-4 log reductions of TC and EC, 5 mg/l PAA resulting in below 2 log reductions. F-RNA coliphages were more resistant against the PAA disinfection and around 1 log reductions of these enteric viruses were typically achieved in the disinfection treatments of the primary, secondary and tertiary effluents. Most of the microbial reductions occurred during the first 4-18 min of contact time, depending on the PAA dose and microorganism. The PAA disinfection efficiency remained relatively constant in the secondary and tertiary effluents, despite of small changes of wastewater quality (COD, SS, turbidity, 253.7 nm transmittance) or temperature. The disinfection efficiency clearly decreased in the primary effluents with substantially higher microbial, organic matter and suspended solids concentrations. The results demonstrated that PAA could be a good alternative disinfection method for elimination of enteric microbes from different wastewaters.
Zhu, Pinkuan; Li, Qianwen; Azad, Sepideh M; Qi, Yu; Wang, Yiwen; Jiang, Yina; Xu, Ling
2018-01-01
Short-wave ultraviolet (UV-C) treatment represents a potent, clean and safe substitute to chemical sanitizers for fresh fruit preservation. However, the dosage requirement for microbial disinfection may have negative effects on fruit quality. In this study, UV-C was found to be more efficient in killing spores of Botrytis cinerea in dark and red light conditions when compared to white and blue light. Loss of the blue light receptor gene Bcwcl1 , a homolog of wc-1 in Neurospora crassa , led to hypersensitivity to UV-C in all light conditions tested. The expression of Bcuve1 and Bcphr1 , which encode UV-damage endonuclease and photolyase, respectively, were strongly induced by white and blue light in a Bcwcl1 -dependent manner. Gene mutation analyses of Bcuve1 and Bcphr1 indicated that they synergistically contribute to survival after UV-C treatment. In vivo assays showed that UV-C (1.0 kJ/m 2 ) abolished decay in drop-inoculated fruit only if the UV-C treatment was followed by a dark period or red light, while in contrast, typical decay appeared on UV-C irradiated fruits exposed to white or blue light. In summary, blue light enhances UV-C resistance in B. cinerea by inducing expression of the UV damage repair-related enzymes, while the efficiency of UV-C application for fruit surface disinfection can be enhanced in dark or red light conditions; these principles seem to be well conserved among postharvest fungal pathogens.
Lui, Gough Yumu; Roser, David; Corkish, Richard; Ashbolt, Nicholas; Jagals, Paul; Stuetz, Richard
2014-09-15
For many decades, populations in rural and remote developing regions will be unable to access centralised piped potable water supplies, and indeed, decentralised options may be more sustainable. Accordingly, improved household point-of-use (POU) disinfection technologies are urgently needed. Compared to alternatives, ultraviolet (UV) light disinfection is very attractive because of its efficacy against all pathogen groups and minimal operational consumables. Though mercury arc lamp technology is very efficient, it requires frequent lamp replacement, involves a toxic heavy metal, and their quartz envelopes and sleeves are expensive, fragile and require regular cleaning. An emerging alternative is semiconductor-based units where UV light emitting diodes (UV-LEDs) are powered by photovoltaics (PV). Our review charts the development of these two technologies, their current status, and challenges to their integration and POU application. It explores the themes of UV-C-LEDs, non-UV-C LED technology (e.g. UV-A, visible light, Advanced Oxidation), PV power supplies, PV/LED integration and POU suitability. While UV-C LED technology should mature in the next 10 years, research is also needed to address other unresolved barriers to in situ application as well as emerging research opportunities especially UV-A, photocatalyst/photosensitiser use and pulsed emission options. Copyright © 2014 Elsevier B.V. All rights reserved.
Zhou, Xiaoqin; Guo, Hao; Li, Zifu; Zhao, Junyuan; Yun, Yupan
2015-11-01
A self-designed continuous-flow ultrasound/ultraviolet (US/UV) baffled reactor was tested in this work, and the disinfection efficiency of secondary effluent from a wastewater treatment plant (WWTP) was investigated in terms of the different locations of ultrasonic transducers inside the reactor under similar input power densities and specific energy consumptions. Results demonstrated that the two-stage simultaneous US/UV irradiation in both chambers 2 and 3 at a flow rate of 1200 L/h performed excellent disinfection efficiency. It achieved an average feacal coliforms concentration of 201±78 colony forming unit (CFU)/L in the effluent and an average of (4.24±0.26) log10 reduction. Thereafter, 8 days of continuous operation was performed under such a condition. A total of 31 samples were taken, and all the samples were analyzed in triplicate for feacal coliforms analysis. Experimental results showed that feacal coliforms concentrations remained at about 347±174 CFU/L under the selected optimum disinfection condition, even if the influent concentrations fluctuated from 3.97×10(5) to 3.57×10(6) CFU/L. This finding implied that all effluents of continuous-flow-baffled-reactor with simultaneous US/UV disinfection could meet the requirements of the discharge standard of pollutants for municipal WWTP (GB 18918-2002) Class 1-A (1000 CFU/L) with a specific energy consumption of 0.219 kWh/m(3). Therefore, the US/UV disinfection process has great potential for practical applications. Copyright © 2015 Elsevier B.V. All rights reserved.
2018-01-01
Hospital-acquired infections (HAIs) are infections that patients contract while in the hospital that were neither present nor developing at the time of admission. In Canada an estimated 10% of adults with short-term hospitalization have HAIs. According to 2003 Canadian data, between 4% and 6% of these patients die from these infections. The most common HAIs in Ontario are caused by Clostridium difficile . The standard method of reducing and preventing these infections is decontamination of patient rooms through manual cleaning and disinfection. Several portable no-touch ultraviolet (UV) light systems have been proposed to supplement current hospital cleaning and disinfecting practices. We searched for studies published from inception of UV disinfection technology to January 23, 2017. We compared portable UV surface-disinfecting devices used together with standard hospital room cleaning and disinfecting versus standard hospital cleaning and disinfecting alone. The primary outcome was HAI from C. difficile . Other outcomes were combined HAIs, colonization (i.e., carrying an infectious agent without exhibiting disease symptoms), and the HAI-associated mortality rate. We used Grading of Recommendations Assessment, Development, and Evaluation (GRADE) to rate the quality of evidence of included studies. We also performed a 5-year budget impact analysis from the hospital's perspective. This assessment was limited to portable devices and did not examine wall mounted devices, which are used in some hospitals. The database search for the clinical review yielded 10 peer-reviewed publications that met eligibility criteria. Three studies focused on mercury UV-C-based technology, seven on pulsed xenon UV technology. Findings were either inconsistent or produced very low-quality evidence using the GRADE rating system. The intervention was effective in reducing the rate of the composite outcome of HAIs (combined) and colonization (but quality of evidence was low). For the review of economic studies, 152 peer-reviewed publications were identified and screened. No studies met the inclusion criteria. Under the assumption that two devices would be purchased per hospital, we estimated the 5-year budget impact of $586,023 for devices that use the pulsed xenon technology and of $634,255 for devices that use the mercury technology. We are unable to make a firm conclusion about the effectiveness of this technology on HAIs given the very low to low quality of evidence. The budget impact estimates are sensitive to assumptions made about the number of UV disinfecting devices purchased per hospital, frequency of daytime use, and staff time required per use.
Nikitovic-Jokic, Milica; Kabali, Conrad; Li, Chunmei; Higgins, Caroline
2018-01-01
Background Hospital-acquired infections (HAIs) are infections that patients contract while in the hospital that were neither present nor developing at the time of admission. In Canada an estimated 10% of adults with short-term hospitalization have HAIs. According to 2003 Canadian data, between 4% and 6% of these patients die from these infections. The most common HAIs in Ontario are caused by Clostridium difficile. The standard method of reducing and preventing these infections is decontamination of patient rooms through manual cleaning and disinfection. Several portable no-touch ultraviolet (UV) light systems have been proposed to supplement current hospital cleaning and disinfecting practices. Methods We searched for studies published from inception of UV disinfection technology to January 23, 2017. We compared portable UV surface-disinfecting devices used together with standard hospital room cleaning and disinfecting versus standard hospital cleaning and disinfecting alone. The primary outcome was HAI from C. difficile. Other outcomes were combined HAIs, colonization (i.e., carrying an infectious agent without exhibiting disease symptoms), and the HAI-associated mortality rate. We used Grading of Recommendations Assessment, Development, and Evaluation (GRADE) to rate the quality of evidence of included studies. We also performed a 5-year budget impact analysis from the hospital's perspective. This assessment was limited to portable devices and did not examine wall mounted devices, which are used in some hospitals. Results The database search for the clinical review yielded 10 peer-reviewed publications that met eligibility criteria. Three studies focused on mercury UV-C–based technology, seven on pulsed xenon UV technology. Findings were either inconsistent or produced very low-quality evidence using the GRADE rating system. The intervention was effective in reducing the rate of the composite outcome of HAIs (combined) and colonization (but quality of evidence was low). For the review of economic studies, 152 peer-reviewed publications were identified and screened. No studies met the inclusion criteria. Under the assumption that two devices would be purchased per hospital, we estimated the 5-year budget impact of $586,023 for devices that use the pulsed xenon technology and of $634,255 for devices that use the mercury technology. Conclusions We are unable to make a firm conclusion about the effectiveness of this technology on HAIs given the very low to low quality of evidence. The budget impact estimates are sensitive to assumptions made about the number of UV disinfecting devices purchased per hospital, frequency of daytime use, and staff time required per use. PMID:29487629
Visible light powered self-disinfecting coatings for influenza viruses
NASA Astrophysics Data System (ADS)
Weng, Ding; Qi, Hangfei; Wu, Ting-Ting; Yan, Ming; Sun, Ren; Lu, Yunfeng
2012-04-01
Influenza A viruses, the pathogens responsible for the recent swine flu outbreak and many historical pandemics, remain a threat to the public health. We report herein the fabrication of self-disinfecting surfaces from photoactive building nanocrystals, which can inactivate influenza viruses rapidly, spontaneously and continuously under visible light illumination.Influenza A viruses, the pathogens responsible for the recent swine flu outbreak and many historical pandemics, remain a threat to the public health. We report herein the fabrication of self-disinfecting surfaces from photoactive building nanocrystals, which can inactivate influenza viruses rapidly, spontaneously and continuously under visible light illumination. Electronic supplementary information (ESI) available: XRD, UV-Vis absorbance, TEM, AFM of as-prepared nanocrystals and as-fabricated self-disinfecting surfaces, disinfection of influenza A virus by TiO2 (P25) with UV irradiation as reference control, photoinactivation of influenza A virus envelope proteins and photoinactivation of trypsin. See DOI: 10.1039/c2nr30388d
Field-testing UV disinfection of drinking water
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gadgil, A.; Drescher, A.; Greene, D.
A recently invented device, ``UV Waterworks,`` uses ultraviolet (UV) light to disinfect drinking water. Its novel features are: low cost, robust design, rapid disinfection, low electricity use, low maintenance, high flow rate and ability to work with unpressurized water sources. The device could service a community of 1,000 persons, at an annual total cost of less than 10 US cents per person. UV Waterworks has been successfully tested in the laboratory. Limited field trials of an early version of the device were conducted in India in 1994--95. Insights from these trials led to the present design. Extended field trials ofmore » UV Waterworks, initiated in South Africa in February 1997, will be coordinated by the South African Center for Essential Community Services (SACECS), with technical and organizational support from Lawrence Berkeley National Laboratory(LBNL) and the Natural Resources Defense Council (both US). The first of the eight planned sites of the year long trial is an AIDS hospice near Durban. Durban metro Water and LBNL lab-tested a UV Waterworks unit prior to installing it at the hospice in August, 1997. The authors describe the field test plans and preliminary results from Durban.« less
Ultraviolet radiation as disinfection for fish surgical tools
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walker, Ricardo W.; Markillie, Lye Meng; Colotelo, Alison HA
Telemetry is frequently used to examine the behavior of fish, and the transmitters used are normally surgically implanted into the coelomic cavity of fish. Implantation requires the use of surgical tools such as scalpels, forceps, needle holders, and sutures. When fish are implanted consecutively, as in large telemetry studies, it is common for surgical tools to be sterilized or, at minimum, disinfected between each use so that pathogens that may be present are not spread among fish. To determine the efficacy for this application, ultraviolet (UV) radiation was used to disinfect surgical tools exposed to one of four aquatic organismsmore » that typically lead to negative health issues for salmonids. These organisms included Aeromonas salmonicida, Flavobacterium psychrophilum, Renibacterium salmoninarum, and Saprolegnia parasitica, causative agents of furunculosis, coldwater disease, bacterial kidney disease, and saprolegniasis (water mold), respectively. Four experiments were conducted to address the question of UV efficacy. In the first experiment, forceps were exposed to the three bacteria at three varying concentrations. After exposure to the bacterial culture, tools were placed into a mobile Millipore UV sterilization apparatus. The tools were then exposed for three different time periods – 2, 5, or 15 min. UV radiation exposures at all durations were effective at killing all three bacteria on forceps at the highest bacteria concentrations. In the second experiment, stab scalpels, sutures, and needle holders were exposed to A. salmonicida using the same methodology as used in Experiment 1. UV radiation exposure at 5 and 15 min was effective at killing A. salmonicida on stab scalpels and sutures but not needle holders. In the third experiment, S. parasitica, a water mold, was tested using an agar plate method and forceps-pinch method. UV radiation was effective at killing the water mold at all three exposure durations. Collectively, this study shows that UV radiation appears to provide a quick alternative disinfection technique to chemical disinfectants (e.g., ethanol) for some surgical tools. However, we do not recommend using this method for tools such as needle holders having overlapping parts or other structures that cannot be exposed directly to UV radiation« less
Reygadas, Fermin; Gruber, Joshua S; Ray, Isha; Nelson, Kara L
2015-11-15
Inconsistent use of household water treatment and safe storage (HWTS) systems reduces their potential health benefits. Ultraviolet (UV) disinfection is more convenient than some existing HWTS systems, but it does not provide post-treatment residual disinfectant, which could leave drinking water vulnerable to recontamination. In this paper, using as-treated analyses, we report on the field efficacy of a UV disinfection system at improving household drinking water quality in rural Mexico. We further assess the risk of post-treatment contamination from the UV system, and develop a process-based model to better understand household risk factors for recontamination. This study was part of a larger cluster-randomized stepped wedge trial, and the results complement previously published population-level results of the intervention on diarrheal prevalence and water quality. Based on the presence of Escherichia coli (proportion of households with ≥ 1 E. coli/100 mL), we estimated a risk difference of -28.0% (95% confidence interval (CI): -33.9%, -22.1%) when comparing intervention to control households; -38.6% (CI: -48.9%, -28.2%) when comparing post- and pre-intervention results; and -37.1% (CI: -45.2%, -28.9%) when comparing UV disinfected water to alternatives within the household. We found substantial increases in post-treatment E. coli contamination when comparing samples from the UV system effluent (5.0%) to samples taken from the storage container (21.1%) and drinking glasses (26.0%). We found that improved household infrastructure, additional extractions from the storage container, additional time from when the storage container was filled, and increased experience of the UV system operator were associated with reductions in post-treatment contamination. Our results suggest that the UV system is efficacious at improving household water quality when used as intended. Promoting safe storage habits is essential for an effective UV system dissemination. The drinking glass appears to represent a small but significant source of recontamination that is likely to impact all HWTS systems. Copyright © 2015 Elsevier Ltd. All rights reserved.
CSO DISINFECTION PILOT STUDY: SPRING CREEK CSO STORAGE FACILITY UPGRADE
This research summary presents the results of a pilot-scale disinfection study performed for the New York City Department of Environmental Protection and the U.S. Environmental Protection Agency (US EPA) under a contract to Camp Dresser & McKee of Woodbury, New York. The main ob...
Influence of UV dose on the UV/H2O2 process for the degradation of carbamazepine in wastewater.
Somathilake, Purnima; Dominic, John Albino; Achari, Gopal; Langford, Cooper H; Tay, Joo-Hwa
2018-05-02
This study evaluates the influence of UV dose on degradation of carbamazepine (CBZ) in wastewater under UV-C (λ = 254 nm) photolysis with and without H 2 O 2 . The rate of degradation of CBZ exhibited a direct dependence on the intensity of incident UV irradiation as the rate of degradation was observed to increase linearly (R 2 = 0.98) with UV intensity between 1.67 and 8.95 × 10 17 photons/s. More than 95% of the CBZ that spiked in wastewater rapidly degraded within 4 min with a first-order rate constant of 1.2 min -1 for an optimum H 2 O 2 dose of 100 mg/L. Bench-scale continuous flow reactor experiments also showed that CBZ degraded with first-order kinetics at a rate constant of 1.02 min -1 . The kinetic parameters obtained for a continuous bench-scale reactor were in good agreement with the relationships developed through batch experiments with only a marginal deviation of ± 6.5%. The relationship between UV intensity and CBZ degradation rate obtained in this study was extrapolated to the UV disinfection unit of a wastewater treatment plant to predict possible degradation of CBZ during UV disinfection. The addition of 100 mg/L of H 2 O 2 to the secondary-treated effluent entering the UV disinfection unit is predicted to achieve over 60% degradation of CBZ.
Selma, María V; Allende, Ana; López-Gálvez, Francisco; Conesa, María A; Gil, María I
2008-09-01
The purpose of this research was to investigate the disinfection efficacy of ozone (O(3)) and UV-C illumination (UV), and their combination (O(3)-UV) for reducing microbial flora of fresh-cut onion, escarole, carrot, and spinach wash waters collected from the industry. Furthermore, the influence of water physicochemical parameters on the decontamination efficacy and the effect of these technologies on physicochemical quality of wash water were analyzed. O(3), UV, and O(3)-UV were effective disinfection treatments on vegetable wash water, with a maximum microbial reduction of 6.6 log CFU mL(-1) after 60 min treatment with O(3)-UV. However, maximum total microbial reductions achieved by UV and O(3) treatments after 60 min were 4.0 and 5.9 log CFU mL(-1), lower than by O(3)-UV treatment. Furthermore, turbidity of wash water was reduced significantly by O(3) and O(3)-UV treatments, while UV treatment did not affect the physicochemical quality of the water. Conclusions derived from this study illustrate that O(3) and O(3)-UV are alternatives to other sanitizers used in the fresh-cut washing processes. The use of these technologies would allow less frequent changing of spent water and the use of much lower sanitizer doses. Nevertheless, in specific applications such as carrot wash water, where levels of undesirable microbial and chemical constituents are lower than other vegetable wash water, UV treatment could be an appropriate treatment considering cost-effectiveness criteria.
Virus Sensitivity Index of UV disinfection.
Tang, Walter Z; Sillanpää, Mika
2015-01-01
A new concept of Virus Sensitivity Index (VSI) is defined as the ratio between the first-order inactivation rate constant of a virus, ki, and that of MS2-phage during UV disinfection, kr. MS2-phage is chosen as the reference virus because it is recommended as a virus indicator during UV reactor design and validation by the US Environmental Protection Agency. VSI has wide applications in research, design, and validation of UV disinfection systems. For example, it can be used to rank the UV disinfection sensitivity of viruses in reference to MS2-phage. There are four major steps in deriving the equation between Hi/Hr and 1/VSI. First, the first-order inactivation rate constants are determined by regression analysis between Log I and fluence required. Second, the inactivation rate constants of MS2-phage are statistically analysed at 3, 4, 5, and 6 Log I levels. Third, different VSI values are obtained from the ki of different viruses dividing by the kr of MS2-phage. Fourth, correlation between Hi/Hr and 1/VSI is analysed by using linear, quadratic, and cubic models. As expected from the theoretical analysis, a linear relationship adequately correlates Hi/Hr and 1/VSI without an intercept. VSI is used to quantitatively predict the UV fluence required for any virus at any log inactivation (Log I). Four equations were developed at 3, 4, 5, and 6 Log I. These equations have been validated using external data which are not used for the virus development. At Log I less than 3, the equation tends to under-predict the required fluence at both low Log I such as 1 and 2 Log I. At Log I greater than 3 Log I, the equation tends to over-predict the fluence required. The reasons for these may very likely be due to the shoulder at the beginning and the tailing at the end of the collimated beam test experiments. At 3 Log I, the error percentage is less than 6%. The VSI is also used to predict inactivation rate constants under two different UV disinfection scenarios such as under sunlight and different virus aggregates. The correlation analysis shows that viruses will be about 40% more sensitive to sunlight than to UV254. On the other hand, virus size of 500 nm will reduce their VSI by 10%. This is the first attempt to use VSI to predict the required fluence at any given Log I. The equation can be used to quantitatively evaluate other parameters influencing UV disinfection. These factors include environmental species, antibiotic-resistant bacteria or genes, photo and dark repair, water quality such as suspended solids, and UV transmittance.
Muzslay, M; Yui, S; Ali, S; Wilson, A P R
2018-04-09
Mobile phones and tablet computers may be contaminated with microorganisms and become a potential reservoir for cross-transmission of pathogens between healthcare workers and patients. There is no generally accepted guidance how to reduce contamination on mobile devices in healthcare settings. Our aim was to determine the efficacy of the Codonics D6000™ UV-C disinfection device. Daily disinfection reduced contamination on screens and on protective cases (test) significantly, but not all cases (control) could be decontaminated. The median aerobic colony count on the control and the test cases was 52 (IQR 33-89) cfu/25cm 2 and 22 (IQR 10.5-41) cfu/25cm 2 respectively before disinfection. Copyright © 2018. Published by Elsevier Ltd.
Is ultraviolet radiation on haemodialysis RO water beneficial?
Stragier, A
2005-01-01
The quality of dialysis fluids has become increasingly important in the treatment of HD patients. Purified water represents over 95% of its volume. Bacterial and endotoxin content of Reverse Osmosis (RO) water is usually kept under control by bacterial filters, inserted in the distribution departure loop, and by monthly disinfection of the distribution circuit; the simpler the circuit, the better. This paper reports 12 years experience during which Ultraviolet Irradiation (UV) has replaced bacterial filters. To keep the bacterial growth under control in a complex RO water circuit (including a tank and multiple loops) a simple UV lamp was inserted in the departure line. It proved sufficient to keep bacterial count within AAMI norms. Failure of the UV lamp was associated with a rise of up to 500 cfu/ml in the last (fourth week) before routine disinfection. Normal levels were again obtained after replacement of the UV lamp. Six years later, a second UV lamp was added on the return loop. Bacterial counts and endotoxin levels in RO water promptly fell to <1 cfu/ml and <0.125 EU, till today. It is concluded that UV lamps should be favoured over bacterial filters in systems that are not disinfected daily, such as the RO water circuit. The principle of UV irradiation is explained and its advantage over bacterial filters is discussed. Future possible applications of UV are presented.
Advanced oxidation and disinfection processes for onsite net-zero greywater reuse: A review.
Gassie, Lucien W; Englehardt, James D
2017-11-15
Net-zero greywater (NZGW) reuse, or nearly closed-loop recycle of greywater for all original uses, can recover both water and its attendant hot-water thermal energy, while avoiding the installation and maintenance of a separate greywater sewer in residential areas. Such a system, if portable, could also provide wash water for remote emergency health care units. However, such greywater reuse engenders human contact with the recycled water, and hence superior treatment. The purpose of this paper is to review processes applicable to the mineralization of organics, including control of oxidative byproducts such as bromate, and maintenance of disinfection consistent with potable reuse guidelines, in NZGW systems. Specifically, TiO 2 -UV, UV-hydrogen peroxide, hydrogen peroxide-ozone, ozone-UV advanced oxidation processes, and UV, ozone, hydrogen peroxide, filtration, and chlorine disinfection processes were reviewed for performance, energy demand, environmental impact, and operational simplicity. Based on the literature reviewed, peroxone is the most energy-efficient process for organics mineralization. However, in portable applications where delivery of chemicals to the site is a concern, the UV-ozone process appears promising, at higher energy demand. In either case, reverse osmosis, nanofiltration, or ED may be useful in controlling the bromide precursor in make-up water, and a minor side-stream of ozone may be used to prevent microbial regrowth in the treated water. Where energy is not paramount, UV-hydrogen peroxide and UV-TiO 2 can be used to mineralize organics while avoiding bromate formation, but may require a secondary process to prevent microbial regrowth. Chlorine and ozone may be useful for maintenance of disinfection residual. Copyright © 2017 Elsevier Ltd. All rights reserved.
Scale-up of electrolytic and photoelectrolytic processes for water reclaiming: a preliminary study.
Martín de Vidales, María J; Cotillas, Salvador; Perez-Serrano, José F; Llanos, Javier; Sáez, Cristina; Cañizares, Pablo; Rodrigo, Manuel A
2016-10-01
This work focuses on the scale-up of electrochemical and photoelectrochemical oxidation processes with diamond anodes for the removal of organic pollutants and disinfection of treated urban wastewater, two of the most important parameters for the reclaiming of wastewater. The removal of organics was studied with actual biologically treated urban wastewater intensified with 100 mg dm(-3) of caffeine, added as a trace organic pollutant. The disinfection was also studied with biologically treated urban wastewater, and Escherichia coli was used to monitor the efficiency of the process. Results obtained with a single DiaCell® 101 were compared with those obtained with a single-stack DiaCell® 1001 and with a pilot plant made up of five of these stacks. Results obtained demonstrate that scale-up is not a simple but a very complex process, in which not only the electrode and the irradiation dose are important but also mass transfer conditions. Enhanced mass transport conditions have a determining and very positive effect on the removal of organics and a negative effect on the disinfection. Likewise, ultraviolet (UV) irradiation affects in a different way in the different setups used, having a great influence on the removal of complex organics and on the speciation of oxidants produced during disinfection. This works helps to understand the key differences observed in the scale-up, and it is a first approach for future works focused on the real application of conductive diamond electrochemical oxidation.
MULTISPECTRAL IDENTIFICATION OF CHLORINE DIOXIDE DISINFECTION BYPRODUCTS IN DRINKING WATER
This paper discusses the identification of organic disinfection byproducts (DBPs) at a pilot plant in Evansville, IN, which uses chlorine dioxide as a primary disinfectant. Unconventional multispectral identification techniques (gas chromatography combined with high- and low reso...
Inactivation/reactivation of antibiotic-resistant bacteria by a novel UVA/LED/TiO2 system.
Xiong, Pei; Hu, Jiangyong
2013-09-01
In this study, an effective photocatalytic disinfection system was established using the newly emerged high power UVA/LED lamp. Crystallizing dish coated with TiO2 was prepared by 32-times impregnation-drying processes, and served as the supporting container for water samples. This study focused on the application of this UVA/LED system for the photocatalytic disinfection of selected antibiotic-resistant bacteria, Escherichia coli ATCC 700891. The disinfection performances were studied under various light intensities and illumination modes. Results show that higher light intensity could reach more significant inactivation of E. coli ATCC 700891. With the same UV dose, log-removal of antibiotic-resistant bacteria decreased with circle time in the studied range, while increased with duty circle. A "residual disinfecting effect" was found in the following dark period for bacteria collected at different phases of photocatalytic process. Residual disinfecting effect was found not significant for bacteria with 30 min periodic illumination. While residual disinfecting effect could kill almost all bacteria after 90 min UV periodic illumination within the following 240 min dark period. Copyright © 2013 Elsevier Ltd. All rights reserved.
Spencer, Maureen; Vignari, Michelle; Bryce, Elizabeth; Johnson, Helen Boehm; Fauerbach, Loretta; Graham, Denise
2017-03-01
Environmental disinfection has become the new frontier in the ongoing battle to reduce the risk of health care-associated infections. Evidence demonstrating the persistent contamination of environmental surfaces despite traditional cleaning and disinfection methods has led to the widespread acceptance that there is both a need for reassessing traditional cleaning protocols and for using secondary disinfection technologies. Ultraviolet-C (UV-C) disinfection is one type of no-touch technology shown to be a successful adjunct to manual cleaning in reducing environmental bioburden. The dilemma for the infection preventionist, however, is how to choose the system best suited for their facility among the many UV-C surface disinfection delivery systems available and how to build a case for acquisition to present to the hospital administration/C-suite. This article proposes an approach to these dilemmas based in part on the experience of 2 health care networks. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
MULTISPECTRAL IDENTIFICATION OF CHLORINE DIOXIDE DISINFECTION BY-PRODUCTS IN DRINKING WATER
This paper discusses the identification of organic disinfection by-products (DBPs) at a pilot plant in Evansville, Indiana, that uses chlorine dioxide as a primary disinfectant. nconventional multispectral identification techniques (gas chromatography combined with high and low r...
Bauer, Stefan; Holtschmidt, Hans; Ott, Günter
2018-01-01
Disinfection by pulsed ultraviolet (UV) radiation is a commonly used method, e.g. in industry or medicine and can be carried out either with lasers or broadband UV radiation sources. Detrimental effects to biological materials depending on parameters such as pulse duration τ or pulse repetition frequency f p are well-understood for pulsed coherent UV radiation, however, relatively little is known for its incoherent variant. Therefore, within this work, it is the first time that disinfection rates of pulsed and continuous (cw) incoherent UV radiation studied by means of spore film dosimetry are presented, compared with each other, and in a second step further investigated regarding two pulse parameters. After analyzing the dynamic range of the Bacillus subtilis spore films with variable cw radiant exposures H=5-100Jm -2 a validation of the Bunsen-Roscoe law revealed its restricted applicability and a 28% enhanced detrimental effect of pulsed compared to cw incoherent UV radiation. A radiant exposure H=50Jm -2 and an irradiance E=0.5Wm -2 were found to be suitable parameters for an analysis of the disinfection rate as a function of τ=0.5-10ms and f p =25-500Hz unveiling that shorter pulses and lower frequencies inactivate more spores. Finally, the number of applied pulses as well as the experiment time were considered with regard to spore film disinfection. Copyright © 2017 Elsevier B.V. All rights reserved.
Barber, Larry B.; Hladik, Michelle; Vajda, Alan M.; Fitzgerald, Kevin C.; Douville, Chris
2015-01-01
The municipal wastewater treatment facility (WWTF) infrastructure of the United States is being upgraded to expand capacity and improve treatment, which provides opportunities to assess the impact of full-scale operational changes on water quality. Many WWTFs disinfect their effluent prior to discharge using chlorine gas, which reacts with natural and synthetic organic matter to form halogenated disinfection byproducts (HDBPs). Because HDBPs are ubiquitous in chlorine-disinfected drinking water and have adverse human health implications, their concentrations are regulated in potable water supplies. Less is known about the formation and occurrence of HDBPs in disinfected WWTF effluents that are discharged to surface waters and become part of the de facto wastewater reuse cycle. This study investigated HDBPs in the urban water cycle from the stream source of the chlorinated municipal tap water that comprises the WWTF inflow, to the final WWTF effluent disinfection process before discharge back to the stream. The impact of conversion from chlorine-gas to low-pressure ultraviolet light (UV) disinfection at a full-scale (68,000 m3 d−1 design flow) WWTF on HDBP concentrations in the final effluent was assessed, as was transport and attenuation in the receiving stream. Nutrients and trace elements (boron, copper, and uranium) were used to characterize the different urban source waters, and indicated that the pre-upgrade and post-upgrade water chemistry was similar and insensitive to the disinfection process. Chlorinated tap water during the pre-upgrade and post-upgrade samplings contained 11 (mean total concentration = 2.7 μg L−1; n=5) and 10 HDBPs (mean total concentration = 4.5 μg L−1), respectively. Under chlorine-gas disinfection conditions 13 HDBPs (mean total concentration = 1.4 μg L−1) were detected in the WWTF effluent, whereas under UV disinfection conditions, only one HDBP was detected. The chlorinated WWTF effluent had greater relative proportions of nitrogenous, brominated, and iodinated HDBPs than the chlorinated tap water. Conversion of the WWTF to UV disinfection reduced the loading of HDBPs to the receiving stream by >90%.
Barber, Larry B; Hladik, Michelle L; Vajda, Alan M; Fitzgerald, Kevin C; Douville, Chris
2015-10-01
The municipal wastewater treatment facility (WWTF) infrastructure of the United States is being upgraded to expand capacity and improve treatment, which provides opportunities to assess the impact of full-scale operational changes on water quality. Many WWTFs disinfect their effluent prior to discharge using chlorine gas, which reacts with natural and synthetic organic matter to form halogenated disinfection byproducts (HDBPs). Because HDBPs are ubiquitous in chlorine-disinfected drinking water and have adverse human health implications, their concentrations are regulated in potable water supplies. Less is known about the formation and occurrence of HDBPs in disinfected WWTF effluents that are discharged to surface waters and become part of the de facto wastewater reuse cycle. This study investigated HDBPs in the urban water cycle from the stream source of the chlorinated municipal tap water that comprises the WWTF inflow, to the final WWTF effluent disinfection process before discharge back to the stream. The impact of conversion from chlorine-gas to low-pressure ultraviolet light (UV) disinfection at a full-scale (68,000 m(3) d(-1) design flow) WWTF on HDBP concentrations in the final effluent was assessed, as was transport and attenuation in the receiving stream. Nutrients and trace elements (boron, copper, and uranium) were used to characterize the different urban source waters, and indicated that the pre-upgrade and post-upgrade water chemistry was similar and insensitive to the disinfection process. Chlorinated tap water during the pre-upgrade and post-upgrade samplings contained 11 (mean total concentration=2.7 μg L(-1); n=5) and 10 HDBPs (mean total concentration=4.5 μg L(-1)), respectively. Under chlorine-gas disinfection conditions 13 HDBPs (mean total concentration=1.4 μg L(-1)) were detected in the WWTF effluent, whereas under UV disinfection conditions, only one HDBP was detected. The chlorinated WWTF effluent had greater relative proportions of nitrogenous, brominated, and iodinated HDBPs than the chlorinated tap water. Conversion of the WWTF to UV disinfection reduced the loading of HDBPs to the receiving stream by >90%. Copyright © 2015. Published by Elsevier B.V.
Ultraviolet light-emitting diodes in water disinfection.
Vilhunen, Sari; Särkkä, Heikki; Sillanpää, Mika
2009-06-01
The novel system of ultraviolet light-emitting diodes (UV LEDs) was studied in water disinfection. Conventional UV lamps, like mercury vapor lamp, consume much energy and are considered to be problem waste after use. UV LEDs are energy efficient and free of toxicants. This study showed the suitability of LEDs in disinfection and provided information of the effect of two emitted wavelengths and different test mediums to Escherichia coli destruction. Common laboratory strain of E. coli (K12) was used and the effects of two emitted wavelengths (269 and 276 nm) were investigated with two photolytic batch reactors both including ten LEDs. The effects of test medium were examined with ultrapure water, nutrient and water, and nutrient and water with humic acids. Efficiency of reactors was almost the same even though the one emitting higher wavelength had doubled optical power compared to the other. Therefore, the effect of wavelength was evident and the radiation emitted at 269 nm was more powerful. Also, the impact of background was studied and noticed to have only slight deteriorating effect. In the 5-min experiment, the bacterial reduction of three to four log colony-forming units (CFU) per cubic centimeter was achieved, in all cases. When turbidity of the test medium was greater, part of the UV radiation was spent on the absorption and reactions with extra substances on liquid. Humic acids can also coat the bacteria reducing the sensitivity of the cells to UV light. The lower wavelength was distinctly more efficient when the optical power is considered, even though the difference of wavelengths was small. The reason presumably is the greater absorption of DNA causing more efficient bacterial breakage. UV LEDs were efficient in E. coli destruction, even if LEDs were considered to have rather low optical power. The effect of wavelengths was noticeable but the test medium did not have much impact. This study found UV LEDs to be an optimal method for bacterial disinfection. The emitted wavelength was found to be an essential factor when using LEDs; thus, care should be taken in selecting the proper LED for maximum disinfection.
High-performance, low-cost solar collectors for disinfection of contaminated water.
Vidal, A; Diaz, A I
2000-01-01
Although the germicidal action of sunlight has long been recognized, its potential for practical applications has to be researched more thoroughly. This paper summarizes the progress made toward a commercially practical collector for solar disinfection applications. Nontracking compound parabolic collectors (CPCs), developed originally for capturing solar photons for thermal energy applications, were examined as potential solar photoreactors. A field demonstration of solar disinfection treatment using commercially manufactured solar reactors was conducted. Field tests showed successful destruction of Escherichia coli and Enterococcus faecalis and have provided data for full-scale design of water treatment systems. From above observations, a throughput value of 50 L/m2 h for the low-cost CPC reactor tested was estimated. For a 190 m3/d (0.05 MGD) facility, the estimated total costs for disinfection using UV-A is U.S. $0.19/m3 ($0.70/1000 gal). The use of near-UV sunlight to disinfect water supplies seems promising in rural communities of developing countries where treated water is unavailable.
Comparison of UV C light and chemicals for disinfection of surfaces in hospital isolation units.
Andersen, B M; Bånrud, H; Bøe, E; Bjordal, O; Drangsholt, F
2006-07-01
To determine the bactericidal effect on surfaces of ceiling- and wall-mounted UV C (UVC) light (wavelength, 254 nm) in isolation units, compared with standard hospital environmental cleaning and chemical disinfection during final disinfection after patients are treated for infections. Microbial samples were obtained from surfaces in isolation units (patient room, anteroom, and bathroom) before and after irradiation with UVC, chloramine disinfection, and standard hospital environmental cleaning. Samples were tested using standard contact plates. Four identical, negative air-pressure isolation units (patient room, anteroom, and bathroom) with a defined number of ceiling- and wall-mounted UVC light units. The UVC distribution was monitored in one isolation unit after irradiation for approximately 40 minutes, corresponding to doses ranging from 160 J/m2 in a shadowed area to 19,230 J/m2 at the mostly highly exposed site (which is high enough to inactivate most bacterial organisms, including spores). UVC disinfection significantly reduced the number of bacteria on surfaces directly or indirectly exposed to UVC to a very low number, as did 5% chloramine disinfection alone (P<.001 for both). Completely shadowed areas in the isolation unit (eg, the bed rail, lockers, and mattresses) still required disinfection by chemicals. Disinfection with UVC light may significantly reduce environmental bacterial contamination and thereby protect the next patient housed in an isolation room. UVC disinfection may not be used alone but is a good addition to chemical disinfection.
Yousefzadeh, Samira; Matin, Atiyeh Rajabi; Ahmadi, Ehsan; Sabeti, Zahra; Alimohammadi, Mahmood; Aslani, Hassan; Nabizadeh, Ramin
2018-04-01
One of the most important aspects of environmental issues is the demand for clean and safe water. Meanwhile, disinfection process is one of the most important steps in safe water production. The present study aims at estimating the performance of UV, nano Zero-Valent Iron particles (nZVI, nano-Fe 0 ), and UV treatment with the addition of nZVI (combined process) for Bacillus subtilis spores inactivation. Effects of different factors on inactivation including contact time, initial nZVI concentration, UV irradiance and various aerations conditions were investigated. Response surface methodology, based on a five-level, two variable central composite design, was used to optimize target microorganism reduction and the experimental parameters. The results indicated that the disinfection time had the greatest positive impact on disinfection ability among the different selected independent variables. According to the results, it can be concluded that microbial reduction by UV alone was more effective than nZVI while the combined UV/nZVI process demonstrated the maximum log reduction. The optimum reduction of about 4 logs was observed at 491 mg/L of nZVI and 60 min of contact time when spores were exposed to UV radiation under deaerated condition. Therefore, UV/nZVI process can be suggested as a reliable method for Bacillus subtilis spores inactivation. Copyright © 2018. Published by Elsevier Ltd.
PULSED UV: REALITIES OF ENHANCED DISINFECTION
Quantitative measurements of the light output from low pressure (LP), medium pressure (MP) and the pulsed UV lamps were made using calibrated spectrometry, chemical actinometry and biodosimetry approaches to compare their relative efficiency in producing germicidal UV energy. Fur...
De Rocker, E; Goen, K; Van Poucke, K
2006-01-01
The efficiency of the disinfection of drain water was tested at 11 greenhouses with tomato cultivation on rockwool substrate in Flanders (Belgium) by means of mycological analysis. In addition the presence of phytopathogenic fungi in the drain water was analysed at 2 supplementary greenhouses with recirculation without disinfection.
[Pilot study on the treatment of ultrafiltration for laundry wastewater recycling and reuse].
Wang, Jin; Jiang, Jin-Hui
2007-02-01
A pilot study of the treatment for laundry wastewater recycling and reuse on the spot was carried out by ultrafiltration (UF) with different membrane material of PAN, PS and PP. According to the analysis of membrane fouling combined with UF effluent quality, PAN membrane was superior to the others. It removed the turbidity, suspended solid, fat oil and grease effectively, but kept anionic surfactant (LAS) to a certain degree in the UF effluent which is beneficial to recycling and reuse. By correlation analysis, it was found the high COD concentration of effluent was caused by LAS remained. The whiteness and softness of cotton cloth washed by UF effluent for a long-term was not different with that washed by tap water. The removal of bacteria and E. coli by UF membrane was not very high, and so UF effluent was disinfected by ultraviolet (UV) further. As the dosage of UV was not less than 3 750 J/m2, the microbial level reached the China national standard of drinking water. The optimal UF operation condition is to backwash two minutes every thirty minutes' filtration. Adopted alkali liquor of pH 11 to 13 to carry out chemical cleaning, the membrane flux was recovered completely.
Vortex Stabilized Plasma for Rapid Water Disinfection & Pharmaceutical Degradation
NASA Astrophysics Data System (ADS)
Hershcovitch, Ady
2016-10-01
Good quality drinking water is dwindling for large segments of the world population. Aggravating the problem is proliferation of antibiotics in the water supply, which give rise to drug resistant pathogens. One option for water supply increase is recycling waste and polluted water by inexpensive, environmentally friendly methods. Presently disinfection uses chemicals and UV radiation. Chemicals are limited by residual toxicity, while UV consumes much electricity. Current methods can remove only certain classes of drugs due to their large variety of physical and chemical properties. Plasmas in water are very attractive for degrading all pharmaceuticals and deactivating pathogens: intense arc current can physically break up any molecular bonds. UV radiation, ozone, etc. generation inside the water volume disinfects. Present utilized plasmas: glow, pulsed arcs are not power efficient; vortex stabilized plasmas are power efficient that can advance water treatment state-of-the-art by orders of magnitude. Proposed techniquefeatures novel components facilitating large diameter vortex stabilized in-water arcs with optimized plasma parameters for maximal UV-C emission; and harvests hydrogen centered by the vortex.
Conventional and advanced oxidation processes used in disinfection of treated urban wastewater.
Rodríguez-Chueca, J; Ormad, M P; Mosteo, R; Sarasa, J; Ovelleiro, J L
2015-03-01
The purpose of the current study is to compare the inactivation of Escherichia coli in wastewater effluents using conventional treatments (chlorination) and advanced oxidation processes (AOPs) such as UV irradiation, hydrogen peroxide (H2O2)/solar irradiation, and photo-Fenton processes. In addition, an analysis of the operational costs of each treatment is carried out taking into account the optimal dosages of chemicals used. Total inactivation of bacteria (7.5 log) was achieved by means of chlorination and UV irradiation. However, bacterial regrowth was observed 6 hours after the completion of UV treatment, obtaining a disinfection value around 3 to 4 log. On the other hand, the combination H2O2/solar irradiation achieved a maximum inactivation of E. coli of 3.30 ± 0.35 log. The photo-Fenton reaction achieved a level of inactivation of 4.87 ± 0.10 log. The order of disinfection, taking into account the reagent/cost ratio of each treatment, is as follows: chlorination > UV irradiation > photo-Fenton > H2O2/sunlight irradiation.
Metcalfe, David; Rockey, Chris; Jefferson, Bruce; Judd, Simon; Jarvis, Peter
2015-12-15
This investigation aimed to compare the disinfection by-product formation potentials (DBPFPs) of three UK surface waters (1 upland reservoir and 2 lowland rivers) with differing characteristics treated by (a) a full scale conventional process and (b) pilot scale processes using a novel suspended ion exchange (SIX) process and inline coagulation (ILCA) followed by ceramic membrane filtration (CMF). Liquid chromatography-organic carbon detection analysis highlighted clear differences between the organic fractions removed by coagulation and suspended ion exchange. Pretreatments which combined SIX and coagulation resulted in significant reductions in dissolved organic carbon (DOC), UV absorbance (UVA), trihalomethane and haloacetic acid formation potential (THMFP, HAAFP), in comparison with the SIX or coagulation process alone. Further experiments showed that in addition to greater overall DOC removal, the processes also reduced the concentration of brominated DBPs and selectively removed organic compounds with high DBPFP. The SIX/ILCA/CMF process resulted in additional removals of DOC, UVA, THMFP, HAAFP and brominated DBPs of 50, 62, 62, 62% and 47% respectively compared with conventional treatment. Copyright © 2015. Published by Elsevier Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor, Paul Allen
The purpose of this report is to present the results of a small pilot-scale test using PAA to disinfect a side stream of the effluent from the ORNL STP. These results provide the basis for requesting approval for full-scale use of PAA at the ORNL STP.
Efficacy of uv irradiation in the microbial disinfection of marine mammal water
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spotte, S.; Buck, J.D.
A study was made on the efficacy of a commercial ultraviolet (UV) sterilizer in reducing the number of bacteria and yeasts in a saline, closed-system marine mammal complex. UV irradiation was effective in lowering bacterial counts in the effluent of the unit (greater than 75% reduction), but bacteria in more remote parts of the water system reached levels equal to or greater than pre-UV counts. Yeast reduction was considerably less, and a trend similar to that of the bacteria was observed in remote sections of the water system. It is concluded that UV irradiation is of limited value in themore » disinfection of marine mammal water. Factors contributing to the poor performance of the sterilizer were the long recycle time of the water and lack of a residual effect.« less
Efficacy of Inactivation of Legionella pneumophila by Multiple-Wavelength UV LEDs
Background: Ultraviolet (UV) light has been successfully used for treating a broad suite of pathogens without the concomitant formation of carcinogenic disinfection by-products (DBPs). However, conventional mercury UV lamps have some practical limitations in water treatment appli...
Efficacy of Inactivation of Human Enteroviruses by Multiple-Wavelength UV LEDs
Ultraviolet (UV) light has been successfully used for treating a broad suite of pathogens without the concomitant formation of carcinogenic disinfection by-products (DBPs). However, conventional mercury UV lamps have some practical limitations in water treatment applications, suc...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walker, Ricardo W.; Markillie, Lye Meng; Colotelo, Alison HA
Telemetry is frequently used to examine the behavior of fish, and the transmitters used are normally surgically implanted into the coelom of fish. Implantation requires the use of surgical tools such as scalpels, forceps, needle holders, and sutures. When several fish are implanted consecutively for large telemetry studies, it is common for surgical tools to be sterilized or, at minimum, disinfected between each use so that pathogens that may be present are not spread among fish. However, autoclaving tools can take a long period of time, and chemical sterilants or disinfectants can be harmful to both humans and fish andmore » have varied effectiveness. Ultraviolet (UV) radiation is commonly used to disinfect water in aquaculture facilities. However, this technology has not been widely used to sterilize tools for surgical implantation of transmitters in fish. To determine its efficacy for this application, Pacific Northwest National Laboratory researchers used UV radiation to disinfect surgical tools (i.e., forceps, needle holder, stab scalpel, and suture) that were exposed to one of four aquatic organisms that typically lead to negative health issues for salmonids. These organisms included Aeromonas salmonicida, Flavobacterium psychrophilum, Renibacterium salmoninarum, and Saprolegnia parasitica. Surgical tools were exposed to the bacteria by dipping them into a confluent suspension of three varying concentrations (i.e., low, medium, high). After exposure to the bacterial culture, tools were placed into a mobile Millipore UV sterilization apparatus. The tools were then exposed for three different time periods—2, 5, or 15 min. S. parasitica, a water mold, was tested using an agar plate method and forceps-pinch method. UV light exposures of 5 and 15 min were effective at killing all four organisms. UV light was also effective at killing Geobacillus stearothermophilus, the organism used as a biological indicator to verify effectiveness of steam sterilizers. These techniques appear to provide a quick alternative disinfection technique for some surgical tools that is less harmful to both humans and fish while not producing chemical waste. However, we do not recommend using these methods with tools that have overlapping parts or other structures that cannot be directly exposed to UV light such as needle holders.« less
Hosein, Ian; Madeloso, Rosie; Nagaratnam, Wijayaratnam; Villamaria, Frank; Stock, Eileen; Jinadatha, Chetan
2016-09-01
Pathogen transmission from contaminated surfaces can cause hospital-associated infections. Although pulsed xenon ultraviolet (PX-UV) light devices have been shown to decrease hospital room bioburden in the United States, their effectiveness in United Kingdom (UK) hospitals is less understood. Forty isolation rooms at the Queens Hospital (700 beds) in North London, UK, were sampled for aerobic bacteria after patient discharge, after manual cleaning with a hypochlorous acid-troclosene sodium solution, and after PX-UV disinfection. PX-UV device efficacy on known organisms was tested by exposing inoculated agar plates in a nonpatient care area. Turnaround times for device usage were recorded, and a survey of hospital staff for perceptions of the device was undertaken. After PX-UV disinfection, the bacterial contamination measured in colony forming units (CFU) decreased by 78.4%, a 91% reduction from initial bioburden levels prior to terminal cleaning. PX-UV exposure resulted in a 5-log CFU reduction for multidrug-resistant organisms (MDROs) on spiked plates. The average device turnaround time was 1 hour, with minimal impact on patient throughput. Ward staff were enthusiastic about device deployment, and device operators reported physical comfort in usage. PX-UV use decreased bioburden in patient discharge rooms and on agar plates spiked with MDROs. The implementation of the PX-UV device was well received by hospital cleaning and ward staff, with minimal disruption to patient flow. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. All rights reserved.
Applicability of UV resistant Bacillus pumilus endospores as a ...
Recent studies have demonstrated the potential to use Bacillus pumilus endospores as a surrogate of human adenovirus (HAdV) in UV disinfection studies. The use of endospores has been limited by observations of batch-to-batch variation in UV sensitivity. This study reports on a propagation method that utilizes a commercially available medium to produce UV tolerant B. pumilus endospores with a consistent UV sensitivity. It is further demonstrated that the endospores B. pumilus strain (ATCC 27142), produced using this protocol (half strength Columbia broth, 5 days incubation, with 0.1mM MnSO4), display a UV dose-response that is similar to that of HAdV. Endospore stocks could be stored in ethanol for up to two month at 4C without a significant change in UV sensitivity. Synergistic endospore damage by pre-pasteurization of water samples was observed, suggesting post-pasteurization only of UV treated water samples. UV tolerant B. pumilus endospores are a potential surrogate of HAdV for UV treatment performance tests in water utilities which do not have in-house research virology laboratories. This article describes the usefulness of Bacillus pumilus endspores as a viable surrogate for adeno virus in UV disinfection studies.
Zhu, Ying; Wang, Haibo; Li, Xiaoxiao; Hu, Chun; Yang, Min; Qu, Jiuhui
2014-09-01
The effect of UV/Cl2 disinfection on the biofilm and corrosion of cast iron pipes in drinking water distribution system were studied using annular reactors (ARs). Passivation occurred more rapidly in the AR with UV/Cl2 than in the one with Cl2 alone, decreasing iron release for higher corrosivity of water. Based on functional gene, pyrosequencing assays and principal component analysis, UV disinfection not only reduced the required initial chlorine dose, but also enhanced denitrifying functional bacteria advantage in the biofilm of corrosion scales. The nitrate-reducing bacteria (NRB) Dechloromonas exhibited the greatest corrosion inhibition by inducing the redox cycling of iron to enhance the precipitation of iron oxides and formation of Fe3O4 in the AR with UV/Cl2, while the rhizobia Bradyrhizobium and Rhizobium, and the NRB Sphingomonas, Brucella producing siderophores had weaker corrosion-inhibition effect by capturing iron in the AR with Cl2. These results indicated that the microbial redox cycling of iron was possibly responsible for higher corrosion inhibition and lower effect of water Larson-Skold Index (LI) changes on corrosion. This finding could be applied toward the control of water quality in drinking water distribution systems. Copyright © 2014 Elsevier Ltd. All rights reserved.
Assessing point-of-use ultraviolet disinfection for safe water in urban developing communities.
Barstow, Christina K; Dotson, Aaron D; Linden, Karl G
2014-12-01
Residents of urban developing communities often have a tap in their home providing treated and sometimes filtered water but its microbial quality cannot be guaranteed. Point-of-use (POU) disinfection systems can provide safe drinking water to the millions who lack access to clean water in urban communities. While many POU systems exist, there are several concerns that can lead to low user acceptability, including low flow rate, taste and odor issues, high cost, recontamination, and ineffectiveness at treating common pathogens. An ultraviolet (UV) POU system was constructed utilizing developing community-appropriate materials and simple construction techniques based around an inexpensive low-wattage, low pressure UV bulb. The system was tested at the bench scale to characterize its hydrodynamic properties and microbial disinfection efficacy. Hydraulically the system most closely resembled a plug flow reactor with minor short-circuiting. The system was challenge tested and validated for a UV fluence of 50 mJ/cm(2) and greater, over varying flow rates and UV transmittances, corresponding to a greater than 4 log reduction of most pathogenic bacteria, viruses, and protozoa of public health concern. This study presents the designed system and testing results to demonstrate the potential architecture of a low-cost, open-source UV system for further prototyping and field-testing.
Huang, Xin; Wang, Long-Yong; Gao, Nai-Yun; Li, Wei-Guo
2012-10-01
The UV-Visible absorption spectrum of industrial wastewater was explored to introduce a substituting method determining the color of water, and to compare the decolorization efficacy of different disinfectants. The results show that the visible absorption spectrum(350-600 nm), instead of ultraviolet absorption spectrum, should be applied to characterize the color of wastewater. There is a good correlation between the features of visible absorption spectrum and the true color of wastewater. Both ozone and chlorine dioxide has a better decolorization performance than chlorine. However, the color of chlorine dioxide itself has a negative effect on decolorization. The changes in the features of visible absorption spectrum effectively reflect the variations in the color of wastewater after disinfection.
Efficacy of Inactivation of Human Enteroviruses by Multiple-Wavelength UV LEDs - abstract
Background: Ultraviolet (UV) light has been successfully used for treating a broad suite of pathogens without the concomitant formation of carcinogenic disinfection by-products (DBPs). However, conventional mercury UV lamps have some practical limitations in water treatment appli...
MONITORING FOR AEROMONAS SPECIES AFTER TREATMENT WITH COMMON DRINKING WATER DISINFECTANTS
The sensitivity of Aeromonas spp. To free chlorine, chloramine and ultraviolet (UV) disinfection was determined. Aeromonas hydrophila is a contaminant listed on the USEPA's 1998 Contaminant Candidate List (CCL). Experiments using free chlorine indicated that the Aeromonas spp. ...
IDENTIFICATION OF TI02/UV DISINFECTION BYPRODUCTS IN DRINKING WATER
Due to concern over the presence of trihalomethanes (THMs) and other chlorinated byproducts in chlorinated drinking water, alternative disinfection methods are being explored. One of the alternative treatment methods currently being evaluated for potential use with small systems ...
Molecular Viability Testing of UV-Inactivated Bacteria.
Weigel, Kris M; Nguyen, Felicia K; Kearney, Moira R; Meschke, John S; Cangelosi, Gerard A
2017-05-15
PCR is effective in detecting bacterial DNA in samples, but it is unable to differentiate viable bacteria from inactivated cells or free DNA fragments. New PCR-based analytical strategies have been developed to address this limitation. Molecular viability testing (MVT) correlates bacterial viability with the ability to rapidly synthesize species-specific rRNA precursors (pre-rRNA) in response to brief nutritional stimulation. Previous studies demonstrated that MVT can assess bacterial inactivation by chlorine, serum, and low-temperature pasteurization. Here, we demonstrate that MVT can detect inactivation of Escherichia coli , Aeromonas hydrophila , and Enterococcus faecalis cells by UV irradiation. Some UV-inactivated E. coli cells transiently retained the ability to synthesize pre-rRNA postirradiation (generating false-positive MVT results), but this activity ceased within 1 h following UV exposure. Viable but transiently undetectable (by culture) E. coli cells were consistently detected by MVT. An alternative viability testing method, viability PCR (vPCR), correlates viability with cell envelope integrity. This method did not distinguish viable bacteria from UV-inactivated bacteria under some conditions, indicating that the inactivated cells retained intact cell envelopes. MVT holds promise as a means to rapidly assess microbial inactivation by UV treatment. IMPORTANCE UV irradiation is increasingly being used to disinfect water, food, and other materials for human use. Confirming the effectiveness of UV disinfection remains a challenging task. In particular, microbiological methods that rely on rapid detection of microbial DNA can yield misleading results, due to the detection of remnant DNA associated with dead microbial cells. This report describes a novel method that rapidly distinguishes living microbial cells from dead microbial cells after UV disinfection. Copyright © 2017 American Society for Microbiology.
Evaluation of Filtration and UV Disinfection for Inactivation of ...
This study evaluated filtration and disinfection processes for removal and inactivation of pathogens in non-community water systems (NCWS) in two surface water supplies. Pretreatment systems included 1) pressure sand filtration, and 2) granular activated carbon adsorption, and 3) cartridge filtration. Two types of low-pressure UV systems were evaluated with and without pretreatment systems. The presentation will provide results for removal of particles and inactivation of MS2 bacteriophage (a viral surrogate) on two surface waters in northeastern Minnesota. Several studies, including a recent study conducted by Minnesota Department of Health (MDH), show that viruses occur in groundwater at a higher rate than expected. Based on preliminary results in Minnesota, virus occurrence appears to be correlated with recharge events such as heavy rainfall and snowmelt. These recharge events are predicted to become more extreme due to climate change impacts. Filtration, ultraviolet (UV) disinfection, and chlorination, can provide a multi-barrier approach for removal or inactivation of pathogens and DBP precursors in both groundwater and surface water systems.
HIGH-RATE DISINFECTION OF COMBINED SEWER OVERFLOW USING CHLORINE DIOXIDE
This presentation is a state-of-the-art review of chlorine dioxide (ClO2) used for high-rate disinfection of combined sewer overflow (CSO). The review includes bench-, pilot-, and fullscale studies on the use of ClO2 as a disinfecting agent for a variety of wastewaters. Specific ...
Assessment and management of the performance risk of a pilot reclaimed water disinfection process.
Zhou, Guangyu; Zhao, Xinhua; Zhang, Lei; Wu, Qing
2013-10-01
Chlorination disinfection has been widely used in reclaimed water treatment plants to ensure water quality. In order to assess the downstream quality risk of a running reclaimed water disinfection process, a set of dynamic equations was developed to simulate reactions in the disinfection process concerning variables of bacteria, chemical oxygen demand (COD), ammonia and monochloramine. The model was calibrated by the observations obtained from a pilot disinfection process which was designed to simulate the actual process in a reclaimed water treatment plant. A Monte Carlo algorithm was applied to calculate the predictive effluent quality distributions that were used in the established hierarchical assessment system for the downstream quality risk, and the key factors affecting the downstream quality risk were defined using the Regional Sensitivity Analysis method. The results showed that the seasonal upstream quality variation caused considerable downstream quality risk; the effluent ammonia was significantly influenced by its upstream concentration; the upstream COD was a key factor determining the process effluent risk of bacterial, COD and residual disinfectant indexes; and lower COD and ammonia concentrations in the influent would mean better downstream quality.
Model of radiation transmittance by inorganic fouling on UV reactor lamp sleeves.
Wait, Isaac W; Blatchley, Ernest R
2010-11-01
The efficacy of UV disinfection of water depends on the ability of radiation to pass from UV lamps through the quartz sleeves that encase them; the accumulation of metal-containing foulants on sleeve surfaces inhibits disinfection by absorbing radiation that would otherwise be available for inactivation. In a series of experiments, the composition and quantity of sleeve foulants were studied relative to water chemistry and sleeve transmittance. Findings indicate that iron and calcium dominate fouling, with elevated fouling activity by iron, aluminum, manganese, and zinc. A regression-based modeling approach was used to characterize and quantify the effects of foulant metals on UV absorbance. The molar extinction coefficient for iron was found to be more than 3 times greater than that of calcium. Iron's relatively high activity in fouling reactions, elevated capacity to absorb UV, and reduced solubility under oxidizing conditions makes it a fouling precursor of particular concern, with respect to potential for sleeve fouling in UV reactors.
US EPA's UV Disinfection Technologies Demonstration Study - States Briefing
EPA report and anticipated Journal articles will provide recommendations & guidance based on lessons learned for subsequent UV technology testing and monitoring/control applications of virus inactivation in drinking water.
Jing, Ming; Wang, Lei
2016-02-15
In the study, 454-pyrosequencing technology was employed to investigate the species of pathogenic bacteria and the proportion of each pathogen in secondary effluent. Culture-based, qPCR and Q-RT-PCR methods were employed to analyze the removal of indicator (E. coli) and pathogen (Salmonella and Mycobacterium) by ultraviolet (UV) disinfection at a dose of 60 mJ x Cm(-2). The results showed that 11 kinds of pathogenic bacteria were found and the most abundant potentially pathogenic bacteria in the secondary effluent were affiliated with the genera of Clostridium (2.96%), Arcobacter (0.82%) and Mycobacterium (0.36%). 99.9% of culturable E. coli and Salmonella were removed by UV disinfection (60 mJ x cm(-2), however, less than 90% of culturable Mycobacterium were removed. The removal efficiencies of viable E. coli, Salmonella and Mycobacterium were low. Q-RT-PCR seemed to be a promising method for evaluating viable microorganisms in samples. Besides, pathogenic bacteria entered into VBNC state at a UV dose of 60 mJ x cm(-2). Other advanced treatment processes were needed to ensure safe utilization of reclaimed water.
The current study evaluates the effectiveness of the combined application of Peracetic acid and ultraviolet radiation as alternative disinfectant agents to the traditional chlorination of wastewater effluents. Various pathogens (E. coli, enterococci and fecal coliforms) were eval...
Leuker, G; Hingst, V
1992-10-01
Using three UV-plants of different technical designs for water disinfection, we studied the conformity between experimental germ reduction using standard test organisms and calculated UV-doses under various water flow conditions. Taking into consideration the style of construction of the UV-plants, the irradiation area and the layer thickness were used as constant parameters for dose calculations. This was also employed for the irradiation intensity, since the experiments were performed for a relatively short period compared of the life span of the UV-irradiators. Both exposure time and water transmission were employed as variable parameters in the dose calculations and experimental procedures respectively. The calculated UV-dose and experimentally obtained germ reduction values were comparatively the same for two of the three UV-plants studied. However, no correlation was observed between the reduction of E. coli and the corresponding calculated UV-dose values. Therefore, the calculated UV-dose values for any given UV-plant should be considered to be relative and by no means absolute values. We are of the opinion that within a certain range of water flow rate and transmission, antimicrobial effectiveness of different UV-plants should be demonstrated independent of dose values, technical and other construction characteristics. The applicability of the UV-plants studied is discussed.
Subtle Differences in Virus Composition Affect Disinfection Kinetics and Mechanisms
Sigstam, Thérèse; Gannon, Greg; Cascella, Michele; Pecson, Brian M.; Wigginton, Krista Rule
2013-01-01
Viral disinfection kinetics have been studied in depth, but the molecular-level inactivation mechanisms are not understood. Consequently, it is difficult to predict the disinfection behavior of nonculturable viruses, even when related, culturable viruses are available. The objective of this work was to determine how small differences in the composition of the viral genome and proteins impact disinfection. To this end, we investigated the inactivation of three related bacteriophages (MS2, fr, and GA) by UV254, singlet oxygen (1O2), free chlorine (FC), and chlorine dioxide (ClO2). Genome damage was quantified by PCR, and protein damage was assessed by quantitative matrix-assisted laser desorption ionization (MALDI) mass spectrometry. ClO2 caused great variability in the inactivation kinetics between viruses and was the only treatment that did not induce genome damage. The inactivation kinetics were similar for all viruses when treated with disinfectants possessing a genome-damaging component (FC, 1O2, and UV254). On the protein level, UV254 subtly damaged MS2 and fr capsid proteins, whereas GA's capsid remained intact. 1O2 oxidized a methionine residue in MS2 but did not affect the other two viruses. In contrast, FC and ClO2 rapidly degraded the capsid proteins of all three viruses. Protein composition alone could not explain the observed degradation trends; instead, molecular dynamics simulations indicated that degradation is dictated by the solvent-accessible surface area of individual amino acids. Finally, despite the similarities of the three viruses investigated, their mode of inactivation by a single disinfectant varied. This explains why closely related viruses can exhibit drastically different inactivation kinetics. PMID:23542618
Verification testing of the Aquionics, Inc. bersonInLine® 4250 UV System to develop the UV delivered dose flow relationship was conducted at the Parsippany-Troy Hills Wastewater Treatment Plant test site in Parsippany, New Jersey. Two full-scale reactors were mounted in series. T...
Yue, Yinling; Zhang, Lan; Ling, Bo
2011-11-01
To investigate the phenomenon of bacteria exceeding standards in rural pit water, which was intermittently operated by water pump equipped with ultrafiltration membrane, and to explore the solutions. Polyvinyl chloride (PVC) alloy capillary membranes combined with UV, disinfectant, one-way valve, water-seal, high water level-water tank and direct outlet were tested. The operation on water treatment was intermittent, simulating the ways of treating pit water in the rural. The combination modes of ultrafiltration membrane with UV, disinfectant and high water level-water tank are valid in solving the problem of high turbidity and microorganism of pit water stored in cellars, the quality of effluents was consistent with the requirements of the national standards. While the combination modes of ultrafiltration membrane with one-way valve or water-seal were less desirable, more bacteria in treated water than raw water were observed because of bacteria breeding on the membrane component. In order to avoid excessive bacteria in filtered pit water caused by intermittent operation, it is recommended that for the pit water in high water level water tanks, the ultrafiltration membranes should be cleaned with disinfectants on a regular basis. The effluent pit water from underground cellars should be disinfected with UV after ultrafiltration.
Power Efficient Plasma Technique for Rapid Water Sterilization
NASA Astrophysics Data System (ADS)
Hershcovitch, Ady
2015-11-01
Water especially good quality drinking water is a dwindling resource for significant segments of the world population. The BBC quoted this article (http://www.ft.com/cms/s/2/8e42bdc8-0838-11e4-9afc-00144feab7de.html) for a claim that water shortage is a bigger problem than climate change. One option for increasing the water supply is to recycle waste and polluted water by inexpensive, environmentally friendly methods. First steps involve filtrations while the last step is water disinfection. Presently disinfection is done chemically and/or UV radiation. Some chemicals cannot be used in large quantity due to residual toxicity, while UV disinfection systems consume a great deal electricity. Plasmas in water are very attractive for water sterilization due to UV radiation, ozone, etc. generation inside the water volume. Commercially available devices like NK-03 Blue Ballast System are used aboard ships for water purification. But, presently utilized plasmas: glow, pulsed arcs are not power efficient. Vortex stabilized plasmas, which are power efficient, can even degrade medications (antibiotics) advancing the state-of-the-art by orders of magnitude, especially when combined with electron beams. Disinfection scheme will be presented. Work supported by Contract No. DE-AC02-98CH1-886 with the US DOE.
Guo, Mei-Ting; Yuan, Qing-Bin; Yang, Jian
2013-11-01
Antibiotic resistance in wastewater is becoming a major public health concern, but poorly understood about impact of disinfection on antibiotic resistant bacteria and antibiotic resistance genes. The UV disinfection of antibiotic resistant heterotrophic bacteria and their relevant genes in the wastewater of a municipal wastewater treatment plant has been evaluated. Two commonly used antibiotics, erythromycin and tetracycline were selected because of their wide occurrences in regard to the antibiotic resistance problem. After UV treatment at a fluence of 5mJcm(-2), the log reductions of heterotrophic bacteria resistant to erythromycin and tetracycline in the wastewater were found to be 1.4±0.1 and 1.1±0.1, respectively. The proportion of tetracycline-resistant bacteria (5%) was nearly double of that before UV disinfection (3%). Tetracycline-resistant bacteria exhibited more tolerance to UV irradiation compared to the erythromycin-resistant bacteria (p<0.05). Gene copy numbers were quantified via qPCR and normalized to the volume of original sample. The total concentrations of erythromycin- and tetracycline-resistance genes were (3.6±0.2)×10(5) and (2.5±0.1)×10(5) copies L(-1), respectively. UV treatment at a fluence of 5mJcm(-2) removed the total erythromycin- and tetracycline-resistance genes by 3.0±0.1 log and 1.9±0.1 log, respectively. UV treatment was effective in reducing antibiotic resistance in the wastewater. Copyright © 2013 Elsevier Ltd. All rights reserved.
Sholtes, Kari A; Lowe, Kincaid; Walters, Glenn W; Sobsey, Mark D; Linden, Karl G; Casanova, Lisa M
2016-09-01
Ultraviolet (UV) light-emitting diodes (LEDs) emitting at 260 nm were evaluated to determine the inactivation kinetics of bacteria, viruses, and spores compared to low-pressure (LP) UV irradiation. Test microbes were Escherichia coli B, a non-enveloped virus (MS-2), and a bacterial spore (Bacillus atrophaeus). For LP UV, 4-log10 reduction doses were: E. coli B, 6.5 mJ/cm(2); MS-2, 59.3 mJ/cm(2); and B. atrophaeus, 30.0 mJ/cm(2). For UV LEDs, the 4-log10 reduction doses were E. coli B, 6.2 mJ/cm(2); MS-2, 58 mJ/cm(2); and B. atrophaeus, 18.7 mJ/cm(2). Microbial inactivation kinetics of the two UV technologies were not significantly different for E. coli B and MS-2, but were different for B. atrophaeus spores. UV LEDs at 260 nm are at least as effective for inactivating microbes in water as conventional LP UV sources and should undergo further development in treatment systems to disinfect drinking water.
Postigo, Cristina; Richardson, Susan D
2014-08-30
Pharmaceuticals are emerging contaminants of concern and are widespread in the environment. While the levels of these substances in finished drinking waters are generally considered too low for human health concern, there are now concerns about their disinfection by-products (DBPs) that can form during drinking water treatment, which in some cases have been proven to be more toxic than the parent compounds. The present manuscript reviews the transformation products of pharmaceuticals generated in water during different disinfection processes, i.e. chlorination, ozonation, chloramination, chlorine dioxide, UV, and UV/hydrogen peroxide, and the main reaction pathways taking place. Most of the findings considered for this review come from controlled laboratory studies involving reactions of pharmaceuticals with these oxidants used in drinking water treatment. Copyright © 2014 Elsevier B.V. All rights reserved.
Lee, JungEun; Zoh, KyungDuk; Ko, GwangPyo
2008-01-01
We studied inactivation and UV disinfection of murine norovirus (MNV) as a surrogate for human norovirus. We investigated the effects of different surface characteristics, temperatures, and NaCl concentrations on MNV survival using both a plaque assay and a real-time TaqMan reverse transcription (RT)-PCR assay. MNV survived more than 40 days on diaper material, on gauze, and in a stool suspension. Compared to inactivation at lower temperatures (−20 and 4°C), inactivation of MNV was greater at higher temperatures (18 and 30°C). On the surface of both gauze and diaper material, there was a <2-log10 reduction in the amount of infectious MNV in 40 days after incubation at both −20 and 4°C, compared to a >5-log10 reduction after incubation at 30°C in 24 days. MNV survived better in a stool suspension than on the surface of gauze or diaper material. A higher salt concentration increased the rate of inactivation of MNV. In 72 h, <0.3-, 1.5-, and 2.5-log10 reductions in the amount of infectious MNV occurred in distilled water and 0.5 and 1 M NaCl, respectively. We observed only minor reductions in the numbers of viral RNA copies as quantified by real-time TaqMan RT-PCR regardless of the temperature, the salt concentration, or the suspending medium. We also evaluated UV disinfection of infectious MNV with and without TiO2. The amount of MNV was significantly reduced by 254-nm UV with and without TiO2. When 25 mJ/cm2 UV was used, 3.3- and 3.6-log10 reductions in the amounts of infectious MNV occurred with and without TiO2, respectively. Our results demonstrate that MNV can persist in various environmental conditions and can be efficiently controlled by UV disinfection. PMID:18245239
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor, Paul Allen
2017-02-01
The purpose of this report is to identify other disinfection methods to replace the current ozone system and propose a small pilot-scale test. Based on a review of the literature and disinfectants used by other wastewater plants in Tennessee, peracetic acid (PAA) was identified as a leading candidate. This report provides the basis for requesting approval for a pilot-scale study using PAA.
Gutiérrez-Alfaro, Sergio; Rueda-Márquez, Juan J; Perales, José A; Manzano, Manuel A
2018-04-01
Solar disinfection (SODIS) of urban wastewater can be a suitable technology for improving the microbiological quality of reclaimed water as a complement to other extensive and environmentally friendly technologies such as microalgae biotreatment. The objective of this work is to evaluate the feasibility of incorporating the SODIS technology at the end of a pilot scale urban wastewater treatment plant (WWTP) where the processes are based on microalgae biotechnology and comprising three Upflow Anaerobic Sludge Blanket (UASB, 20m 3 each one) reactor, six High Rate Algal Ponds (HRAP, 32m 2 each one), and a Dissolved Air Flotation (DAF, 1m 3 ) unit. E. coli concentration was monitored at the effluent of the different units (UASB, HRAP, DAF) of the pilot WWTP. The efficiency of the SODIS process was studied for the inactivation of three of the commonly employed indicator microorganisms (Escherichia coli, Enterococcus spp. and Clostridium perfringens) using a compound parabolic collector (CPC) for five months under various conditions of irradiance and temperature. E. coli and Enterococcus spp. were more effectively disinfected by the SODIS unit (2.9 and 2.5 logarithms of reduction on average, respectively) than by the HRAP (2 and 1.1) or the DAF (0.9 and 0.1). On the contrary, the DAF technology achieved better reduction rates of C. perfringens (1.7) than the SODIS (0.9) and the HRAP (0.1). No regrowth of any microorganisms was detected during dark storage after the SODIS treatment. Incorporating a SODIS unit after the non-conventional WWTP processes substantially increases the possibilities for reuse of the treated water after receiving a cumulative UV radiation dose of 25W·h/m 2 (50min of normalized time of solar illumination). The surface requirement of the SODIS equipment would be 3.5 times smaller than the HRAP's surface. Copyright © 2017 Elsevier B.V. All rights reserved.
Synergistic effect of solar radiation and solar heating to disinfect drinking water sources.
Rijal, G K; Fujioka, R S
2001-01-01
Waterborne diseases are still common in developing countries as drinking water sources are contaminated and feasible means to reliably treat and disinfect these waters are not available. Many of these developing countries are in the tropical regions of the world where sunlight is plentiful. The objective of this study was to evaluate the effectiveness of combining solar radiation and solar heating to disinfect contaminated water using a modified Family Sol*Saver System (FSP). The non-UV transmittable cover sheet of the former FSP system was replaced with an UV transmittable plastic cover sheet to enable more wavelengths of sunlight to treat the water. Disinfection efficiency of both systems was evaluated based on reduction of the natural populations of faecal coliform, E. coli, enterococci, C. perfringens, total heterotrophic bacteria, hydrogen sulphide producing bacteria and FRNA virus. The results showed that under sunny and partly sunny conditions, water was heated to critical temperature (60 degrees C) in both the FSP systems inactivating more than 3 log (99.9%) of the concentrations of faecal coliform and E. coli to undetectable levels of < 1 CFU/100 mL within 2-5 h exposure to sunlight. However, under cloudy conditions, the two FSP systems did not reduce the concentrations of faecal indicator bacteria to levels of < 1 CFU/100 mL. Nonetheless, sufficient evidence was obtained to show that UV radiation of sunlight plus heat worked synergistically to enhance the inactivation of faecal indicator bacteria. The relative log removal of indicator microorganism in the FSP treated water was total heterotrophic bacteria < C. perfringens < F RNA virus < enterococci < E. coli < faecal coliform. In summary, time of exposure to heat and radiation effects of sunlight were important in disinfecting water by solar units. The data indicated that direct radiation of sunlight worked synergistically with solar heating of the water to disinfect the water. Thus, effective disinfection was observed even when the water temperature did not reach 60 degrees C. Finally, the hydrogen sulphide test is a simple and reliable test that householders can use to determine whether their water had been sufficiently disinfected.
Ultraviolet disinfection of water for small water supplies
NASA Astrophysics Data System (ADS)
Carlson, D. A.; Seabloom, R. W.; Dewalle, F. B.; Wetzler, T. F.; Engeset, J.
1985-07-01
In the study ultraviolet radiation was considered as an alternative means of disinfection of small drinking water supplies. A major impetus for the study was the large increase in waterborne disease episodes in the United States whose etiologic agent, Giardia lamblia, was found to be highly resistant to conventional chlorination. While the germicidal effect of sunlight has long been known, it has been found that artificial UV radiation with a wavelength of 253.7 nm, can be produced by low pressure mercury vapor lamps. The inactivation of microorganisms by UV radiation is based upon photochemical reactions in DNA which result in errors in the coding system. Inactivation of microorganisms due to exposure to UV is proportional to the intensity multiplied by the time of exposure.
Recent studies have demonstrated the potential to use Bacillus pumilus endospores as a surrogate of human adenovirus (HAdV) in UV disinfection studies. The use of endospores has been limited by observations of batch-to-batch variation in UV sensitivity. This study reports on a pr...
Assessment of a low-cost, point-of-use, ultraviolet water disinfection technology.
Brownell, Sarah A; Chakrabarti, Alicia R; Kaser, Forest M; Connelly, Lloyd G; Peletz, Rachel L; Reygadas, Fermin; Lang, Micah J; Kammen, Daniel M; Nelson, Kara L
2008-03-01
We describe a point-of-use (POU) ultraviolet (UV) disinfection technology, the UV Tube, which can be made with locally available resources around the world for under $50 US. Laboratory and field studies were conducted to characterize the UV Tube's performance when treating a flowrate of 5 L/min. Based on biological assays with MS2 coliphage, the UV Tube delivered an average fluence of 900+/-80 J/m(2) (95% CI) in water with an absorption coefficient of 0.01 cm(-1). The residence time distribution in the UV Tube was characterized as plug flow with dispersion (Peclet Number = 19.7) and a mean hydraulic residence time of 36 s. Undesirable compounds were leached or produced from UV Tubes constructed with unlined ABS, PVC, or a galvanized steel liner. Lining the PVC pipe with stainless steel, however, prevented production of regulated halogenated organics. A small field study in two rural communities in Baja California Sur demonstrated that the UV Tube reduced E. coli concentrations to less than 1/100 ml in 65 out of 70 samples. Based on these results, we conclude that the UV Tube is a promising technology for treating household drinking water at the point of use.
Magnuson, Matthew L; Kelty, Catherine A; Sharpless, Charles M; Linden, Karl G; Fromme, William; Metz, Deborah H; Kashinkunti, Ramesh
2002-12-01
Ohio River water was treated by settling, sand filtration, and granular activated carbon filtration. It was then irradiated by low-pressure (monochromatic) and medium-pressure (polychromatic) UV lamps to investigate the effects of UV irradiation on the extracted organic matter (EOM). When the EOM, collected by solid phase extraction cartridges, was analyzed by conventional UV spectroscopy and size exclusion chromatography (SEC), no significant changes in the EOM were revealed for various UV doses. Positive and negative electrospray ionization mass spectrometry (ESI-MS) of the EOM produced mass spectra that vary significantly with UV dose. The UV dosage conditions also appear to affect the reactivity of the EOM to subsequent chlorination. The magnitude of the spectral changes is generally greater for medium-pressure lamps than for low pressure and increases with UV exposure. Based on the observed MS peaks, the changes may be due to the presence of lignin, resulting perhaps from photooxidation and/or photo rearrangement of macromolecules in the sample. When chlorination is used for secondary disinfection, these results suggest that it may be important to consider the effects of UV irradiation on the organic matter in the water before applying UV disinfection technology to a particular source water.
DEVELOP NEW TOTAL ORGANIC CARBON/SPECIFIC UV ...
The purpose of this project is to provide a total organic carbon (TOC)/specific ultraviolet absorbance (SUVA) method that will be used by the Office of Ground Water and Drinking Water (OGWDW) to support monitoring requirements of the Stage 2 Disinfectant/Disinfection By-products (D/DBP) Rule. The Stage 2 Rule requires that enhanced water treatment be used if the source water is high in aquatic organic matter prior to the application of a disinfectant. Disinfectants (chlorine, ozone, etc.) are used in the production of drinking water in order to reduce the risk of microbial disease. These disinfectants react with the organic material that is naturally present in the source water to form disinfection by-products (DBPs). Exposure to some of these by-products may pose a long term health risk. The number and nature of DBPs make it impossible to fully characterize all of the by-products formed during the treatment of drinking water and it is more cost effective to reduce formation of DBPs than to remove them from the water after they are formed. Two measurements (TOC and SUVA) are believed to be predictive of the amount of by-products that can be formed during the disinfection of drinking water and are considered to be surrogates for DBP precursors. SUVA is calculated as the ultraviolet absorption at 254nm (UV254) in cm-1 divided by the mg/L dissolved organic carbon (DOC) concentration (measured after filtration of the water through a 0.45um pore-diameter filte
USDA-ARS?s Scientific Manuscript database
A continuous water disinfection process can be used to prevent the introduction and accumulation of obligate and opportunistic fish pathogens in recirculating aquaculture systems (RAS), especially during a disease outbreak when the causative agent would otherwise proliferate within the system. To p...
This study evaluated filtration and disinfection processes for removal and inactivation of pathogens in non-community water systems (NCWS) in two surface water supplies. Pretreatment systems included 1) pressure sand filtration, and 2) granular activated carbon adsorption, and 3...
Determining UV Inactivation of Toxoplasma gondii Oocysts by Using Cell Culture and a Mouse Bioassay
The effect of UV exposure on Toxoplasma gondii oocysts has not been completely defined for use in water disinfection. This study evaluated UV irradiated oocysts by three assays: a SCID mouse bioassay, an in vitro T. gondii oocyst plaque assay (TOP-assay), and a quantitative reve...
MULTISPECTRAL IDENTIFICATION OF CHLORINE DIOXIDE BYPRODUCTS IN DRINKING WATER
This paper discusses the identification of organic disinfectant byproducts (DNPS) at a pilot plant in Evansville, IN, that uses chlorine dioxide as a primary disinfectant. nconventional multispectral identification techniques (gas chromatography combined with high- and low-resolu...
Cheema, Waqas A; Manasfi, Tarek; Kaarsholm, Kamilla M S; Andersen, Henrik R; Boudenne, Jean-Luc
2017-12-01
Several brominated disinfection by-products (DBPs) are formed in chlorinated seawater pools, due to the high concentration of bromide in seawater. UV irradiation is increasingly employed in freshwater pools, because UV treatment photodegrades harmful chloramines. However, in freshwater pools it has been reported that post-UV chlorination promotes the formation of other DBPs. To date, UV-based processes have not been investigated for DBPs in seawater pools. In this study, the effects of UV, followed by chlorination, on the concentration of three groups of DBPs were investigated in laboratory batch experiments using a medium-pressure UV lamp. Chlorine consumption increased following post-UV chlorination, most likely because UV irradiation degraded organic matter in the pool samples to more chlorine-reactive organic matter. Haloacetic acid (HAA) concentrations decreased significantly, due to photo-degradation, but the concentrations of trihalomethanes (THMs) and haloacetonitriles (HANs) increased with post-UV chlorination. Bromine incorporation in HAAs was significantly higher in the control samples chlorinated without UV irradiation but decreased significantly with UV treatment. Bromine incorporation was promoted in THM and HAN after UV and chlorine treatment. Overall, the accumulated bromine incorporation level in DBPs remained essentially unchanged in comparison with the control samples. Toxicity estimates increased with single-dose UV and chlorination, mainly due to increased HAN concentrations. However, brominated HANs are known in the literature to degrade following further UV treatment. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
SilvestryRodriquez, Nadia
2010-01-01
There is the need for a safe, low energy consuming and compact water disinfection technology to maintain water quality for human consumption. The design of the reactor should present no overheating and a constant temperature, with good electrical and optical performance for a UV water treatment system. The study assessed the use of UVA-LEDs to disinfectant water for MS2 Bacteriophage. The log reduction was sufficient to meet US EPA standards as a secondary disinfectant for maintaining water quality control. The study also explored possible inactivation of Pseudomonas aeruginosa and E. coli.
Jinadatha, Chetan; Quezada, Ricardo; Huber, Thomas W; Williams, Jason B; Zeber, John E; Copeland, Laurel A
2014-04-07
Healthcare-acquired infections with methicillin-resistant Staphylococcus aureus (MRSA) are a significant cause of increased mortality, morbidity and additional health care costs in United States. Surface decontamination technologies that utilize pulsed xenon ultraviolet light (PPX-UV) may be effective at reducing microbial burden. The purpose of this study was to compare standard manual room-cleaning to PPX-UV disinfection technology for MRSA and bacterial heterotrophic plate counts (HPC) on high-touch surfaces in patient rooms. Rooms vacated by patients that had a MRSA-positive polymerase chain reaction or culture during the current hospitalization and at least a 2-day stay were studied. 20 rooms were then treated according to one of two protocols: standard manual cleaning or PPX-UV. This study evaluated the reduction of MRSA and HPC taken from five high-touch surfaces in rooms vacated by MRSA-positive patients, as a function of cleaning by standard manual methods vs a PPX-UV area disinfection device. Colony counts in 20 rooms (10 per arm) prior to cleaning varied by cleaning protocol: for HPC, manual (mean = 255, median = 278, q1-q3 132-304) vs PPX-UV (mean = 449, median = 365, q1-q3 332-530), and for MRSA, manual (mean = 127; median = 28.5; q1-q3 8-143) vs PPX-UV (mean = 108; median = 123; q1-q3 14-183). PPX-UV was superior to manual cleaning for MRSA (adjusted incident rate ratio [IRR] = 7; 95% CI <1-41) and for HPC (IRR = 13; 95% CI 4-48). PPX-UV technology appears to be superior to manual cleaning alone for MRSA and HPC. Incorporating 15 minutes of PPX-UV exposure time to current hospital room cleaning practice can improve the overall cleanliness of patient rooms with respect to selected micro-organisms.
2014-01-01
Background Healthcare-acquired infections with methicillin-resistant Staphylococcus aureus (MRSA) are a significant cause of increased mortality, morbidity and additional health care costs in United States. Surface decontamination technologies that utilize pulsed xenon ultraviolet light (PPX-UV) may be effective at reducing microbial burden. The purpose of this study was to compare standard manual room-cleaning to PPX-UV disinfection technology for MRSA and bacterial heterotrophic plate counts (HPC) on high-touch surfaces in patient rooms. Methods Rooms vacated by patients that had a MRSA-positive polymerase chain reaction or culture during the current hospitalization and at least a 2-day stay were studied. 20 rooms were then treated according to one of two protocols: standard manual cleaning or PPX-UV. This study evaluated the reduction of MRSA and HPC taken from five high-touch surfaces in rooms vacated by MRSA-positive patients, as a function of cleaning by standard manual methods vs a PPX-UV area disinfection device. Results Colony counts in 20 rooms (10 per arm) prior to cleaning varied by cleaning protocol: for HPC, manual (mean = 255, median = 278, q1-q3 132–304) vs PPX-UV (mean = 449, median = 365, q1-q3 332–530), and for MRSA, manual (mean = 127; median = 28.5; q1-q3 8–143) vs PPX-UV (mean = 108; median = 123; q1-q3 14–183). PPX-UV was superior to manual cleaning for MRSA (adjusted incident rate ratio [IRR] = 7; 95% CI <1-41) and for HPC (IRR = 13; 95% CI 4–48). Conclusion PPX-UV technology appears to be superior to manual cleaning alone for MRSA and HPC. Incorporating 15 minutes of PPX-UV exposure time to current hospital room cleaning practice can improve the overall cleanliness of patient rooms with respect to selected micro-organisms. PMID:24708734
Plasma processes in water under effect of short duration pulse discharges
NASA Astrophysics Data System (ADS)
Gurbanov, Elchin
2013-09-01
It is very important to get a clear water without any impurities and bacteria by methods, that don't change the physical and chemical indicators of water now. In this article the plasma processes during the water treatment by strong electric fields and short duration pulse discharges are considered. The crown discharge around an electrode with a small radius of curvature consists of plasma leader channels with a high conductivity, where the thermo ionization processes and UV-radiation are taken place. Simultaneously the partial discharges around potential electrode lead to formation of atomic oxygen and ozone. The spark discharge arises, when plasma leader channels cross the all interelectrode gap, where the temperature and pressure are strongly grown. As a result the shock waves and dispersing liquid streams in all discharge gap are formed. The plasma channels extend, pressure inside it becomes less than hydrostatic one and the collapse and UV-radiation processes are started. The considered physical processes can be successfully used as a basis for development of pilot-industrial installations for conditioning of drinking water and to disinfecting of sewage.
Al-Gabr, Hamid Mohammad; Zheng, Tianling; Yu, Xin
2013-10-01
The disinfection process for inactivating microorganisms at drinking water treatment plants is aimed for safety of drinking water for humans from a microorganism, such as bacteria, viruses, algae, fungi by using chlorination, ozonation, UV irradiation, etc. In the present study, a combination of two disinfectants, UV irradiation followed by chlorination, was evaluated for inactivating Aspergillus flavus under low contact time and low dosage of UV irradiation. The results indicated an inverse correlation between the inactivation of A. flavus by using UV irradiation only or chlorination alone. By using UV radiation, the 2 log10 control of A. flavus was achieved after 30 s of irradiation, while chlorination was observed to be more effective than UV, where the 2 log was achieved at chlorine concentration of 0.5, 1, 2 and 3 mg/l, in contact time of 60, 5, 1 and 1 min, respectively. However, combined use (UV irradiation followed by chlorination) was more effective than using either UV or chlorination alone; 5 s UV irradiation followed by chlorination produced 4 log10 reduction of A. flavus at chlorine concentrations of 2 and 3 mg/l under a contact time of 15 min. The results indicated that efficiency of UV irradiation improves when followed by chlorination at low concentrations. Copyright © 2013 Elsevier B.V. All rights reserved.
VERIFICATION TESTING OF HIGH-RATE MECHANICAL INDUCTION MIXERS FOR CHEMICAL DISINFECTANTS
This paper describes the results of verification testing of mechanical induction mixers for dispersion of chemical disinfectants in wet-weather flow (WWF) conducted under the U.S. Environmental Protection Agency's Environmental Technology Verification (ETV) WWF Pilot Program. Th...
A pilot study on using chlorine dioxide gas for disinfection of gastrointestinal endoscopes* #
Yi, Ying; Hao, Li-mei; Ma, Shu-ren; Wu, Jin-hui; Wang, Tao; Lin, Song; Zhang, Zong-xing; Qi, Jian-cheng
2016-01-01
Objectives: This pilot study of employing chlorine dioxide (CD) gas to disinfect gastrointestinal endoscopes was conducted to meet the expectations of many endoscopy units in China for a high-efficiency and low-cost disinfectant. Methods: An experimental prototype with an active circulation mode was designed to use CD gas to disinfect gastrointestinal endoscopes. One type of testing device composed of polytetrafluoroethylene (PTFE) tubes (2 m long, inner diameter 1 mm) and bacterial carrier containers was used to simulate the channel of the endoscope. PTFE bacterial carriers inoculated with Bacillus atrophaeus with or without organic burden were used to evaluate the sporicidal activity of CD gas. Factors including exposure dosage, relative humidity (RH), and flow rate (FR) influencing the disinfection effect of CD gas were investigated. Moreover, an autoptic disinfecting test on eight real gastrointestinal endoscopes after clinical use was performed using the experimental prototype. Results: RH, exposure dosage, organic burden, and the FR through the channel significantly (P<0.05) affected the disinfection efficacy of CD gas for a long and narrow lumen. The log reduction increased as FR decreased. Treatment with 4 mg/L CD gas for 30 min at 0.8 L/min FR and 75% RH, resulted in complete inactivation of spores. Furthermore, all eight endoscopes with a maximum colony-forming unit of 915 were completely disinfected. The cost was only 3 CNY (0.46 USD) for each endoscope. Conclusions: The methods and results reported in this study could provide a basis for further studies on using CD gas for the disinfection of endoscopes. PMID:27381729
Lehotsky, Á; Szilágyi, L; Bánsághi, S; Szerémy, P; Wéber, G; Haidegger, T
2017-09-01
Ultraviolet spectrum markers are widely used for hand hygiene quality assessment, although their microbiological validation has not been established. A microbiology-based assessment of the procedure was conducted. Twenty-five artificial hand models underwent initial full contamination, then disinfection with UV-dyed hand-rub solution, digital imaging under UV-light, microbiological sampling and cultivation, and digital imaging of the cultivated flora were performed. Paired images of each hand model were registered by a software tool, then the UV-marked regions were compared with the pathogen-free sites pixel by pixel. Statistical evaluation revealed that the method indicates correctly disinfected areas with 95.05% sensitivity and 98.01% specificity. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, J.E.; Whisnant, R.B.
The report provides an in-depth evaluation of an ultraviolet (UV) disinfection unit as applied to the treatment of cooling water in a textile air washer system. The UV unit tests used a teflon tube to transport the aquatic phase. The unit reduced microbial populations and maintained an average level of 10,000 Colony formed unites/mL for the 6-month testing period, without the addition of biocides. No cleaning or other maintenance was required of the wetted surfaces during the testing period. Slime deposits observed on walls of the air washer during chemical treatment were also eliminated. The UV unit can be utilizedmore » on both cooling towers and air washers without extensive installation.« less
Study on a New Ultraviolet Sterilizer to the Surface Disinfection of the Ultrasound Probe.
Chen, Gui Qiu; Chen, Yu Hao; Yi, Liang; Yin, Jin; Gao, Qiong; Song, Jiang Nan; Li, Shi Kang; Chen, Pei Hou; Guo, Gui Ping
2018-02-01
We studied the disinfection effect of a new ultraviolet (UV) sterilizer and its utilization on ultrasound probe surfaces. Carrier quantitative germicidal tests, simulated on-the-spot trials, and organic substance influence tests were used to carry out experimental observation. Artificially infected probes were disinfected using the sterilizer or a germicidal lamp for comparison. The total number and types of bacteria were determined and identified. Our results demonstrated the sterilizer had the best disinfection effect among three different disinfection methods in hospital. The sterilizer has been used in a hospital setting for 2 years with no notable damage to the ultrasound probe instrument. It has the advantages of fast disinfection, high disinfection effect, and good compatibility with the ultrasound instrument, worthy of being a promoted application in medical institutions. Copyright © 2018 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.
Manasfi, Tarek; Coulomb, Bruno; Ravier, Sylvain; Boudenne, Jean-Luc
2017-12-05
Organic ultraviolet (UV) filters are used in sunscreens and other personal-care products to protect against harmful effects of exposure to UV solar radiation. Little is known about the fate of UV filters in seawater swimming pools disinfected with chlorine. The present study investigated the occurrence and fate of five commonly used organic UV filters, namely dioxybenzone, oxybenzone, avobenzone, 2-ethylhexyl-4-methoxycinnamate, and octocrylene, in chlorinated seawater swimming pools. Pool samples were collected to monitor the variation of UV filter concentrations during pool opening hours. Furthermore, laboratory-controlled chlorination experiments were conducted in seawater spiked with UV filters to investigate the reactivity of UV filters. Extracts of chlorination reaction samples were analyzed using high-resolution mass spectrometry and electron-capture detection to identify the potentially formed byproducts. In the collected pool samples, all the UV filters except dioxybenzone were detected. Chlorination reactions showed that only octocrylene was stable in chlorinated seawater. The four reactive UV filters generated brominated transformation products and disinfection byproducts. This formation of brominated products resulted from reactions between the reactive UV filters and bromine, which is formed rapidly when chlorine is added to seawater. Based on the identified byproducts, the transformation pathways of the reactive UV filters were proposed for the first time. Bromoform was generated by all the reactive UV filters at different yields. Bromal hydrate was also detected as one of the byproducts generated by oxybenzone and dioxybenzone.
Chen, Shi; Deng, Jing; Li, Lei; Gao, Naiyun
2018-02-01
This study evaluated the effect of low-pressure ultraviolet (UV) irradiation on the formation of disinfection by-products (DBPs) from algal organic matter of Microcystis aeruginosa during subsequent chlorination and chloramination. The algal organic matter includes extracellular organic matter (EOM) and intracellular organic matter (IOM). The fluorescence excitation-emission matrix spectra indicated that the humic/fulvic acid-like organics of EOM and the protein-like organics of IOM may be preferentially degraded by UV treatment. UV irradiation with low specific UV absorbance values was effective in reducing the formation of trihalomethanes and dichloroacetic acid from EOM and IOM during the subsequent chlorination. During the UV-chloramine process, higher UV dose (1000 mJ/cm 2 ) led to the decrease of the formation of dichloroacetic acid, trichloroacetic acid, and haloketones from IOM by an average of 24%. Furthermore, UV irradiation can slightly increase the bromine substitution factors (BSFs) of haloacetic acids from EOM during chlorination, including dihaloacetic acids and trihaloacetic acids in the presence of bromide (50 μg/L). However, UV irradiation did not shift the formation of DBPs from IOM to more brominated species, since the BSFs of trihalomethanes, dihaloacetic acids, trihaloacetic acids, and dihaloacetonitriles almost kept unchanged during UV-chlorine process. As for UV-chloramine process, UV irradiation decreased the BSFs of trihalomethanes, while increased the BSFs of dihaloacetic acid for both EOM and IOM. Overall, the UV pretreatment process is a potential technology in treating algae-rich water.
VERIFICATION TESTING OF HIGH-RATE MECHANICAL INDUCTION MIXERS FOR CHEMICAL DISINFECTANTS, Oregon
This paper describes the results of verification testing of mechanical induction mixers for dispersion of chemical disinfectants in wet-weather flow (WWF) conducted under the U.S. Environmental Protection Agency's Environmental Technology Verification (ETV) WWF Pilot Program. Th...
Hess-Erga, Ole-Kristian; Blomvågnes-Bakke, Bente; Vadstein, Olav
2010-10-01
Transport of ballast water with ships represents a risk for introduction of foreign species. If ballast water is treated during uptake, there will be a recolonization of the ballast water by heterotrophic bacteria during transport. We investigated survival and succession of heterotrophic bacteria after disinfection of seawater in the laboratory, representing a model system of ballast water treatment and transport. The seawater was exposed to ultraviolet (UV) irradiation, ozone (2 doses) or no treatment, incubated for 16 days and examined with culture-dependent and -independent methods. The number of colony-forming units (CFU) was reduced below the detection level after disinfection with UV and high ozone dose (700 mV), and 1% of the initial level for the low ozone dose (400 mV). After less than 3 days, the CFU was back or above the starting point for the control, UV and low ozone treatment, whereas it took slightly more than 6 days for the high ozone treatment. Disinfection increased substrate availability and reduced cell densities. Lack of competition and predation induced the recolonization by opportunistic bacteria (r-strategists), with significant increase in bacterial numbers and a low diversity (based on DGGE band pattern). All cultures stabilized after the initial recolonization phase (except Oz700) where competition due to crowding and nutrient limitation favoured bacteria with high substrate affinity (K-strategists), resulting in higher species richness and diversity (based on DGGE band pattern). The bacterial community was significantly altered qualitatively and quantitatively and may have a higher potential as invaders in the recipient depending on disinfection method and the time of release. These results have implications for the treatment strategy used for ballast water. Copyright © 2010 Elsevier Ltd. All rights reserved.
Chen, Chao; Zhang, Xiaojian; He, Wenjie; Lu, Wei; Han, Hongda
2007-08-15
Organic matter in source water has presented many challenges in the field of water purification, especially for conventional treatment. A two-year-long pilot test comparing water treatment processes was conducted to enhance organic matter removal. The tested process combinations included the conventional process, conventional plus advanced treatment, pre-oxidation plus conventional process and pre-oxidation plus conventional plus advanced treatment. The efficiency of each kind of process was assayed with the comprehensive indices of COD(Mn), TOC, UV(254), AOC, BDOC, THMs, and HAAs and their formation potential. The results showed that the combination of the conventional process and O(3)-BAC provides integrated removal of organic matter and meets the required standards. It is the best performing treatment tested in this investigation for treating polluted source water in China. Moreover, much attention should be paid to organic removal before disinfection to control DBP formation and preserve biostability. This paper also reports the range of efficiency of each unit process to calculate the total efficiency of different process combinations in order to help choose the appropriate water treatment process.
Yang, Guang-Feng; Feng, Li-Juan; Yang, Qi; Zhu, Liang; Xu, Jian; Xu, Xiang-Yang
2014-11-01
The quality of raw water is getting worse in developing countries because of the inadequate treatment of municipal sewage, industrial wastewater and agricultural runoff. Aiming at the biofilm enrichment and pollutant removal, two pilot-scale biofilm reactors were built with different biological carriers. Results showed that compared with the blank carrier, the biofilm was easily enriched on the biofilm precoated carrier and less nitrite accumulation occurred. The removal efficiencies of NH4(+)-N, DOC and UV254 increased under the aeration condition, and a optimum DO level for the adequate nitrification was 1.0-2.6mgL(-1) with the suitable temperature range of 21-22°C. Study on the trihalomethane prediction model indicated that the presentence of algae increased the risk of disinfection by-products production, which could be effectively controlled via manual algae removing and light shading. In this study, the performance of biofilm pretreatment process could be enhanced under the optimized condition of DO level and biofilm carrier. Copyright © 2014 Elsevier Ltd. All rights reserved.
Zhu, Shengwei; Srebric, Jelena; Rudnick, Stephen N.; Vincent, Richard L.; Nardell, Edward A.
2013-01-01
This study investigated the disinfection efficacy of the upper-room ultraviolet germicidal irradiation (UR-UVGI) system with ceiling fans. The investigation used the steady-state Computational Fluid Dynamics (CFD) simulations to solve the rotation of ceiling fan with a rotating reference frame. Two ambient air exchange rates, 2 ACH and 6 ACH (air changes per hour), and four downward fan rotational speeds, 0 rpm, 80 rpm, 150 rpm, and 235 rpm were considered. Additionally, the passive scalar concentration simulations incorporated ultraviolet (UV) dose by two methods: one based on the total exposure time and average UV fluence rate, and another based on SVE3* (New Scale for Ventilation Efficiency 3), originally defined to evaluate the mean age of the air from an air supply opening. Overall, the CFD results enabled the evaluation of UR-UVGI disinfection efficacy using different indices, including the fraction of remaining microorganisms, equivalent air exchange rate, UR-UVGI effectiveness, and tuberculosis infection probability by the Wells-Riley equation. The results indicated that air exchange rate was the decisive factor for determining UR-UVGI performance in disinfecting indoor air. Using a ceiling fan could also improve the performance in general. Furthermore, the results clarified the mechanism for the ceiling fan to influence UR-UVGI disinfection efficacy. PMID:23311354
UV TREATMENT FOR CONTROL OF AEROMONAS (RM.C.M.6)
The data and related interpretations that will be developed in this research will form the scientific basis for analysis, design, and regulation of polychromatic UV disinfection systems. At present, only minimal data regarding the wavelength-specific nature of microbial dose-resp...
Photodegradation of pharmaceuticals and personal care products during UV and UV/H2O2 treatments.
Kim, Ilho; Yamashita, Naoyuki; Tanaka, Hiroaki
2009-10-01
Photodegradation characteristics of pharmaceuticals and personal care products (PPCPs) and the effectiveness of H(2)O(2) addition for PPCPs photodegradation during UV treatment were examined in this study. Average k (1st order rate constant) value for all the PPCPs investigated increased by a factor of 1.3 by H(2)O(2) addition during UV treatment using biologically treated water (TW) spiked with the 30 PPCPs. Therefore, the effectiveness of H(2)O(2) addition for PPCPs removal during UV treatment in real wastewater treatment process was expected. It could be also known that H(2)O(2) addition would improve photodegradation rates of PPCPs highly resistant for UV treatment such as DEET, ethenzamide and theophylline. UV dose required for 90% degradation of each PPCP was calculated from k values obtained in UV and UV/H(2)O(2) treatment experiments using TW spiked with 30 PPCPs. For UV treatment, UV dose required for degrading each PPCP by 90% of initial concentration ranged from 38 mJ cm(-2) to 5644 mJ cm(-2), indicating that most of PPCPs will not be removed sufficiently in UV disinfection process in wastewater treatment plant. For UV/H(2)O(2) treatment, all the PPCPs except seven PPCPs including cyclophosphamide and 2-QCA were degraded by more than 90% by UV irradiation for 30 min (UV dose: 691 mJ cm(-2)), indicating that H(2)O(2) addition during UV treatment will be highly effective for improving the degradation of PPCPs by UV, even though much higher UV dose is still necessary comparing to for UV disinfection.
Rutala, William A; Kanamori, Hajime; Gergen, Maria; Sickbert-Bennett, Emily; Knelson, Lauren P; Chen, Luke F; Anderson, Deverick; Sexton, Daniel; Weber, David J
2017-01-01
Abstract Background Contaminated environmental surfaces are involved in the transmission of epidemiologically important pathogens. It remains unknown which level of microbial load can contribute to healthcare-associated infections (HAI). We used microbiological data obtained from the Benefits of Enhanced Terminal Room (BETR) Disinfection Study to investigate the quantitative relationship between microbial burden and risk of HAI. Methods Microbiological samples were collected from high-frequency-touch hospital room surfaces using Rodac plates (25 cm2/plate) in rooms after terminal room disinfection. All rooms were randomly assigned to standard disinfection (Quaternary ammonium [Quat]) or an enhanced disinfection (Quat/ultraviolet light [UV-C], Bleach, Bleach/UV-C). The Quat/UV-C arm was excluded from further analysis since HAI were not observed in this arm. All new patients in study rooms were monitored for HAI following terminal disinfection through the BETR study standard protocols. We analyzed the relationship between the total colony forming units (CFU) of bacterial loads from 2,395 environmental samples in 60 rooms and HAI among new patients in the room (6 patients with HAI and 54 patients without HAI). Each arm had 2 patients with HAI. Statistical significance was determined by the Wilcoxon test, and P < 0.05 was considered significant. Results Overall, samples in rooms of patients with HAI had a mean 39.3 CFU, while samples from rooms of patients without HAI had a mean 35.6 CFU (Table 1). In the standard disinfection, the sampled rooms from the HAI patients had a significantly higher number of total CFU (mean 65.1 CFU) than non-HAI group (mean 35.5 CFU) (P = 0.019). In the enhanced disinfection rooms, there was no statistical significance between HAI and non-HAI groups. Conclusion Although our sample size may have been too small to detect contaminated microbial load in a room though a large clinical trial was conducted, our data based on the Quat arm as standard disinfection demonstrated the significant relationship between microbial load and HAI. Disclosures D. Sexton, Centers for Disease Control and Prevention: Grant Investigator, Grant recipient. Centers for Disease Control and Prevention Foundation: Grant Investigator, Grant recipient. UpToDate: Collaborator, Royalty Recipient. D. J. Weber, PDI: Consultant, Consulting fee
Characteristic correlation study of UV disinfection performance for ballast water treatment
NASA Astrophysics Data System (ADS)
Ba, Te; Li, Hongying; Osman, Hafiiz; Kang, Chang-Wei
2016-11-01
Characteristic correlation between ultraviolet disinfection performance and operating parameters, including ultraviolet transmittance (UVT), lamp power and water flow rate, was studied by numerical and experimental methods. A three-stage model was developed to simulate the fluid flow, UV radiation and the trajectories of microorganisms. Navier-Stokes equation with k-epsilon turbulence was solved to model the fluid flow, while discrete ordinates (DO) radiation model and discrete phase model (DPM) were used to introduce UV radiation and microorganisms trajectories into the model, respectively. The UV dose statistical distribution for the microorganisms was found to move to higher value with the increase of UVT and lamp power, but moves to lower value when the water flow rate increases. Further investigation shows that the fluence rate increases exponentially with UVT but linearly with the lamp power. The average and minimum resident time decreases linearly with the water flow rate while the maximum resident time decrease rapidly in a certain range. The current study can be used as a digital design and performance evaluation tool of the UV reactor for ballast water treatment.
Schiavano, Giuditta Fiorella; De Santi, Mauro; Sisti, Maurizio; Amagliani, Giulia; Brandi, Giorgio
2017-09-13
Nontuberculous mycobacteria are resistant to conventional water treatments, and are opportunistic human pathogen, particularly in hospitalized patients. The aim of this investigation was to assess the effectiveness of an ultraviolet UV-C lamp treatment against Mycobacterium avium subspecies hominissuis in drinking tap water. Ultraviolet treatments (0-192 mJ/cm 2 ) were performed using UV lamp immerged onto cylindrical glass tubes containing artificially contaminated water. The results showed that susceptibility to UV varied considerably according to the strains and the diameter of the tube. With a dose of 32 mJ/cm 2 , a significant inactivation (p < .05) of 3 log (99.9%) or more was obtained in only 5 of the 14 strains. To obtain a complete inactivation of all strains an irradiation of 192 mJ/cm 2 was needed, a dose that is much higher than the limits recommended by the international standards for UV disinfection of drinking water. In conclusion, it may be difficult to standardize a UV dose for the elimination of waterborne mycobacteria.
Simultaneous control of microorganisms and disinfection by-products by sequential chlorination.
Chen, Chao; Zhang, Xiao-Jian; He, Wen-Jie; Han, Hong-Da
2007-04-01
To introduce a new sequential chlorination disinfection process in which short-term free chlorine and chloramine are sequentially added. Pilot tests of this sequential chlorination were carried out in a drinking water plant. The sequential chlorination disinfection process had the same or better efficiency on microbe (including virus) inactivation compared with the free chlorine disinfection process. There seemed to be some synergetic disinfection effect between free chlorine and monochloramine because they attacked different targets. The sequential chlorination disinfection process resulted in 35.7%-77.0% TTHM formation and 36.6%-54.8% THAA5 formation less than the free chlorination process. The poorer the water quality was, the more advantage the sequential chlorination disinfection had over the free chlorination. This process takes advantages of free chlorine's quick inactivation of microorganisms and chloramine's low disinfection by-product (DBP) yield and long-term residual effect, allowing simultaneous control of microbes and DBPs in an effective and economic way.
NASA Astrophysics Data System (ADS)
Argyraki, A.; Markvart, M.; Nielsen, Anne; Bjarnsholt, T.; Bjørndal, L.; Petersen, P. M.
2016-04-01
Disinfection routines are important in all clinical applications. The uprising problem of antibiotic resistance has driven major research efforts towards alternative disinfection approaches, involving light-based solutions. Pseudomonas aeruginosa (P. aeruginosa) is a common bacterium that can cause skin, soft tissue, lungs, kidney and urinary tract infections. Moreover, it can be found on and in medical equipment causing often cross infections in hospitals. The objective of this study was to test the efficiency, of two different light-based disinfection treatments, namely UVB and UVC irradiation, on P. aeruginosa biofilms at different growth stages. In our experiments a new type of UV light emitting diodes (LEDs) were used to deliver UV irradiation on the biofilms, in the UVB (296nm) and UVC (266nm) region. The killing rate was studied as a function of dose for 24h grown biofilms. The dose was ramped from 72J/m2 to 10000J/m2. It was shown that UVB irradiation was more effective than UVC irradiation in inactivating P. aeruginosa biofilms. No colony forming units (CFU) were observed for the UVB treated biofilms when the dose was 10000 J/m2 (CFU in control sample: 7.5 x 104). UVB irradiation at a dose of 20000J/m2 on mature biofilms (72h grown) resulted in a 3.9 log killing efficacy. The fact that the wavelength of 296nm exists in daylight and has such disinfection ability on biofilms gives new perspectives for applications within disinfection at hospitals.
Life cycle assessment study on polishing units for use of treated wastewater in agricultural reuse.
Büyükkamacı, Nurdan; Karaca, Gökçe
2017-12-01
A life cycle assessment (LCA) approach was used in the assessment of environmental impacts of some polishing units for reuse of wastewater treatment plant effluents in agricultural irrigation. These alternative polishing units were assessed: (1) microfiltration and ultraviolet (UV) disinfection, (2) cartridge filter and ultrafiltration (UF), and (3) just UV disinfection. Two different energy sources, electric grid mix and natural gas, were considered to assess the environmental impacts of them. Afterwards, the effluent of each case was evaluated against the criteria required for irrigation of sensitive crops corresponding to Turkey regulations. Evaluation of environmental impacts was carried out with GaBi 6.1 LCA software. The overall conclusion of this study is that higher electricity consumption causes higher environmental effects. The results of the study revealed that cartridge filter and UF in combination with electric grid mix has the largest impact on the environment for almost all impact categories. In general, the most environmentally friendly solution is UV disinfection. The study revealed environmental impacts for three alternatives drawing attention to the importance of the choice of the most appropriate polishing processes and energy sources for reuse applications.
Integrated oxide graphene based device for laser inactivation of pathogenic microorganisms
NASA Astrophysics Data System (ADS)
Grishkanich, Alexsandr; Ruzankina, Julia; Afanasyev, Mikhail; Paklinov, Nikita; Hafizov, Nail
2018-02-01
We develop device for virus disinfection of pathogenic microorganisms. Viral decontamination can be carried out due to hard ultraviolet irradiation and singlet oxygen destroying the genetic material of a virus capsid. UV rays can destroy DNA, leading to the formation of dimers of nucleic acids. This practically does not occur in tissues, tk. UV rays penetrate badly through them, however, the viral particles are small and UV can destroy their genetic material, RNA / DNA and the virus can not replicate. It is with the construction of the ultraviolet laser water disinfection system (UFLOV) based on the continuous and periodic pulsed ultraviolet laser sources (pump) binds to solve sterility and depyrogenation of water. It has been established that small doses of UV irradiation stimulate reproduction, and large doses cause the death of pathogenic microorganisms. The effect of a dose of ultraviolet is the result of photochemical action on the substance of a living bacterial cell or virion. Also complex photodynamic laser inactivation on graphene oxide is realized.
UV disinfection and flocculation-chlorination sachets to reduce hepatitis E virus in drinking water.
Guerrero-Latorre, Laura; Gonzales-Gustavson, Eloy; Hundesa, Ayalkibet; Sommer, Regina; Rosina, Girones
2016-07-01
Hepatitis E Virus (HEV) is a major cause of waterborne outbreaks in areas with poor sanitation. As safe water supplies are the keystone for preventing HEV outbreaks, data on the efficacy of disinfection treatments are urgently needed. Here, we evaluated the ability of UV radiation and flocculation-chlorination sachets (FCSs) to reduce HEV in water matrices. The HEV-p6-kernow strain was replicated in the HepG2/C3A cell line, and we quantified genome number using qRT-PCR and infectivity using an immunofluorescence assay (IFA). UV irradiation tests using low-pressure radiation showed inactivation kinetics for HEV of 99.99% with a UV fluence of 232J/m(2) (IC 95%, 195,02-269,18). Moreover, the FCSs preparations significantly reduced viral concentrations in both water matrices, although the inactivation results were under the baseline of reduction (4.5 LRV) proposed by WHO guidelines. Copyright © 2016 Elsevier GmbH. All rights reserved.
Uneke, Chigozie J; Ndukwe, Chinwendu D; Nwakpu, Kingsley O; Nnabu, Richard C; Ugwuoru, Cletus D; Prasopa-Plaizier, Nittita
2014-01-15
This study aimed to assess the impact of a stethoscope disinfection sensitization campaign among doctors and nurses in a Nigerian teaching hospital. The design was a before-and-after study. Pre-program measurements were used to provide a baseline against which the post-program results were compared. Interventions that promoted compliance with stethoscope disinfection practice that were implemented included training and education on stethoscope disinfection and introduction of 70% isopropyl alcohol disinfectant at points-of-care places. Microbiological assessment of stethoscopes used by health workers was conducted after the intervention and the outcome was compared with the pilot study results. After the intervention, of the 89 stethoscopes screened, 18 (20.2%) were contaminated with bacterial agents. A higher prevalence of stethoscope contamination was observed among stethoscopes from the intensive care unit (66.7%), the VIP unit (50%), and the antenatal unit (37.5%). The main isolates were Staphylococcus aureus (44.4%) and Escherichia coli (50%). The antibiotic sensitivity assessment indicated that the bacterial isolates were resistant to nearly all the antibiotics tested. All the 89 health workers whose stethoscopes were screened after the intervention admitted to cleaning their stethoscopes after seeing each patient, representing a compliance rate of 100%, unlike the 15% compliance at the pilot phase. The baseline stethoscope contamination rate was 78.5% versus 20.2% post-intervention. Training and education and introduction of alcohol-based disinfectants inexpensive but very effective methods to improve stethoscope disinfection compliance among health workers in low-income settings.
Slide presentation at Conference: ASCE 7th Civil Engineering Conference in the Asian Region. USEPA in partnership with the Cadmus Group, Carollo Engineers, and other State & Industry collaborators, are evaluating new approaches for validating UV reactors to meet groundwater & sur...
A newly developed integrated cell culture reverse transcriptase quantitative PCR (ICC-RTqPCR) method and its applicability in UV disinfection studies is described. This method utilizes a singular cell culture system coupled with four RTqPCR assays to detect infectious serotypes t...
The halosol process for water disinfection and dehalogenation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Acra, A.; Jurdi, M.; Mu'allem, H.
Substitution of chlorine and its derivatives as agents to disinfect water and wastewater effluents because of concern for the formation of the mutagenic and carcinogenic trihalomethanes (THM) may be a protracted endeavor. Excess chlorine residuals need to be controlled by dechlorinated agents, e.g., SO{sub 2}, to avoid esthetic objections voiced by consumers and the risk to aquatic environments. We focused on the phenomenon of photodecomposition and aqueons halogen solutions by sunlight. The halosol process, a batch system for solar dehalogenation, was developed into a flow-through system for the halosol disinfection of water. A prototype facility incorporated a solar reactor, throughmore » which chlorinated water flowed, made of borosilicate glass tube with a serpentine shape supported by a frame. Disinfection is induced by two cooperative biocidal agents (a halogen and sunlight) with sequential solar dehalogenation. An overall mean photodechlorination rate, K, of 0.238 m{sup 2}/W-h was obtained. The calculated solar UV-A fluence required to reduce the initial chlorine residuals by 90% and 99% was 9.65 and 19.30 W-h/m{sup 2}. The most effective photodechlorination components of sunlight were in the UV-A region of the spectrum: effectiveness decreased exponentially with wavelength.« less
Rijal, G K; Fujioka, R S
2003-01-01
Aluminum reflectors were added to solar units designed to inactivate faecal microorganisms (faecal coliform, E. coli, enterococci, FRNA coliphage, C. perfringens) in stream water and diluted sewage by the two mechanisms (solar heat, solar UV) known to inactivate microorganisms. During sunny conditions, solar units with and without reflectors inactivated E. coli to <1 CFU/100 ml to meet drinking water standards. Solar units with reflectors disinfected the water sooner by increasing the water temperature by 8-10 degrees C to 64-75 degrees C. However, FRNA coliphages were still detected in these samples, indicating that this treatment may not inactivate pathogenic human enteric viruses. During cloudy conditions, reflectors only increased the water temperature by 3-4 degrees C to a maximum of 43-49 degrees C and E. coli was not completely inactivated. Under sunny and cloudy conditions, the UV wavelengths of sunlight worked synergistically with increasing water temperatures and were able to disinfect microorganisms at temperatures (45-56 degrees C), which were not effective in inactivating microorganisms. Relative resistance to the solar disinfecting effects were C. perfringens > FRNA coliphages > enterococci > E. coli > faecal coliform.
Trujillo, J; Barrios, J A; Jimenez, B
2008-01-01
Water supply for human consumption requires certain quality that reduces health risks to consumers. In this sense, the process of disinfection plays an important role in the elimination of pathogenic microorganisms. Even though chlorination is the most applied process based on its effectiveness and cost, its application is being questioned considering the formation of disinfection by-products (DBPs). Therefore, alternative disinfectants are being evaluated and some treatment processes have been proposed to remove DBPs precursors (organic matter. This paper reports the results of disinfection of a non conventional source of water (aquifer recharged unintentionally with raw wastewater) with peracetic acid (PAA) and ultraviolet radiation (UV) as well as nanofiltration (NF) followed by chlorination to produce safe drinking water. The results showed that a dose of 2 mg/L PAA was needed to eliminate total and faecal coliforms. For UV light, a dose of 12.40 mWs/cm2 reduced total and faecal coliforms below the detection limit. On the other hand, chlorine demand of water before NF was 1.1-1.3 mg/L with a trihalomethane formation potential (THMFP) of 118.62 microg/L, in contrast with chlorination after NF where the demand was 0.5 mg/L and THMFP of 17.64 microg/L. The recommended scheme is nanofiltration + chlorination.
Evaluating UV-C LED disinfection performance and investigating potential dual-wavelength synergy
This study evaluated ultraviolet (UV) light emitting diodes (LEDs) emitting at 260 nm, 280 nm, and the combination of 260|280 nm together for their efficacy at inactivating Escherichia. coli, MS2 coliphage, human adenovirus type 2 (HAdV2), and Bacillus pumilus spores; research in...
Qiao, Yang; Chen, Daoyi; Wen, Diya
2018-06-04
The development of subsea injection water disinfection systems will enable the novel exploration of offshore oilfields. Ultraviolet light emitting diodes (UV-LEDs) with peak wavelengths at 255 nm, 280 nm, 350 nm, and combinations of 255 nm and 350 nm, and 280 nm and 350 nm were investigated in this study to determine their efficiency at disinfecting saprophytic bacteria, iron bacteria, and sulfate reducing bacteria. Results show that UV-LEDs with peak wavelengths at 280 nm were the most practical in this domain because of their high performance in both energy-efficiency and reactivation suppression, although 255 nm UV-LEDs achieved an optimal germicidal effect in dose-based experiments. The use of combined 280 nm and 350 nm wavelengths also induced synergistic bactericidal effects on saprophytic bacteria. Copyright © 2018. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Wolska, Małgorzata; Szerzyna, Sławomir; Machi, Justyna; Mołczan, Marek; Adamski, Wojciech; Wiśniewski, Jacek
2017-11-01
The presence of organic substances in the water intaken for consumption could be hazardous to human health due to the potential formation of disinfection by-products (TOX). The study were carried out in the pilot surface water treatment system consisting of coagulation, sedimentation, filtration, ozonation, adsorption and disinfection. Due to continuous operation of the system and interference with the parameters of the processes it was possible not only assess the effectiveness of individual water treatment processes in removing TOX, but also on factors participating on the course of unit processes.
Impacts of Goethite Particles on UV Disinfection of Drinking Water
Wu, Youxian; Clevenger, Thomas; Deng, Baolin
2005-01-01
A unique association between bacterial cells and small goethite particles (∼0.2 by 2 μm) protected Escherichia coli and Pseudomonas putida from UV inactivation. The protection increased with the particle concentration in the turbidity range of 1 to 50 nephelometric turbidity units and with the bacterium-particle attachment time prior to UV irradiation. The lower degree of bacterial inactivation at longer attachment time was mostly attributed to the particle aggregation surrounding bacteria that provided shielding from UV radiation. PMID:16000835
[Disinfecting contact tonometers - a systematic review].
Neubauer, A S; Heeg, P; Kampik, A; Hirneiss, C
2009-05-01
The aim of this study is to provide the best available evidence on how to disinfect contact Goldman tonometers. A systematic review of all articles on disinfection of contact tonometers was conducted. Articles published up to July 2008 were identified in Medline, Embase and references from included articles. Two observers participated in the data retrieval and assessment of the studies identified. A total of 89 articles was retrieved, of which 58 could be included. Of those, 18 were clinical studies, 17 experimental microbiological studies, 8 expert assessments or guidelines and 15 reviews, surveys, descriptions of new methods. The clinical studies illustrate the importance of the problem, possible side effects of some disinfection methods but yield inconclusive results regarding efficacy. Experimental studies investigated a variety of bacterial and virological questions as well as material damage by disinfection. Both chlorine-based and hydrogen peroxide-based liquid disinfection were shown to be effective if applied for 5 min. Inconsistent results exist for alcohol wipes and UV disinfection - material damage has been described for both. The US guidelines and most expert recommendations are supported by evidence of the existing data. Chlorine-based and hydrogen peroxide-based liquid disinfections for 5 minutes are effective and relatively safe for disinfecting contact tonometers.
Ultraviolet Light Disinfection in the Use of Individual Water Purification Devices
2006-03-01
adenovirus, Giardia lamblia, Giardia muris , and Cryptosporidium parvum. Adenovirus was evaluated because it is considered the most resistant to...7 reproduce cannot infect and are thereby inactivated. Subsequently, when evaluating UV disinfection capability, Giardia cyst and...0.25 to 20 NTU resulted in a 0.8-log and 0.5-log decrease in inactivation of Cryptosporidium and Giardia , respectively (reference 3). The type of
Secondary formation of disinfection by-products by UV treatment of swimming pool water.
Spiliotopoulou, Aikaterini; Hansen, Kamilla M S; Andersen, Henrik R
2015-07-01
Formation of disinfection by-products (DBPs) during experimental UV treatment of pool water has previously been reported with little concurrence between laboratory studies, field studies and research groups. In the current study, changes in concentration of seven out of eleven investigated volatile DBPs were observed in experiments using medium pressure UV treatment, with and without chlorine and after post-UV chlorination. Results showed that post-UV chlorine consumption increased, dose-dependently, with UV treatment dose. A clear absence of trihalomethane formation by UV and UV with chlorine was observed, while small yet statistically significant increases in dichloroacetonitrile and dichloropropanone concentrations were detected. Results indicate that post-UV chlorination clearly induced secondary formation of several DBPs. However, the formation of total trihalomethanes was no greater than what could be replicated by performing the DBP formation assay with higher chlorine concentrations to simulate extended chlorination. Post-UV chlorination of water from a swimming pool that continuously uses UV treatment to control combined chlorine could not induce secondary formation for most DBPs. Concurrence for induction of trihalomethanes was identified between post-UV chlorination treatments and simulated extended chlorination time treatment. Trihalomethanes could not be induced by UV treatment of water from a continuously UV treated pool. This indicates that literature reports of experimentally induced trihalomethane formation by UV may be a result of kinetic increase in formation by UV. However, this does not imply that higher trihalomethane concentrations would occur in pools that apply continuous UV treatment. The bromine fraction of halogens in formed trihalomethanes increased with UV dose. This indicates that UV removes bromine atoms from larger molecules that participate in trihalomethane production during post-UV chlorination. Additionally, no significant effect on DBP formation was observed due to photo-inducible radical forming molecules NO3- (potentially present in high concentrations in pool water) and H2O2 (added as part of commercially employed DBP reducing practices). Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Ye, Linchao; Belloni, Paola; Möller, Knut
2011-10-01
Within the framework of a project conducted together with an industrial partner, a self-disinfecting operation interface with a glass panel is being developed. The concept of self-disinfection is based on the exploitation of the photocatalytical effect induced by a TiO2-coating on the glass surface under UV(A) light, which would make the touch screen antimicrobial. High-power UV-LEDs instead of conventional UV-lamps have been employed as light source. The main goal and challenge of the optical design is to generate an efficient and preferably homogeneous UV field on the TiO2-coated side while keeping the UV-LEDs concealed, i.e. invisible to the user. Therefore common backlighting systems have been used as reference and modified to meet the concrete requirements. Primary analysis and optical simulations have been performed with the software LightTools®. Several patterns for light redirection (i.e. 3D-spherical texture, 3D-rectangular texture and 2D-circular serigraph) have been investigated, compared and evaluated. Finally the pattern design which both fulfills all the predefined boundary conditions and simultaneously reduces the costs has been chosen.
Lyon, Bonnie A; Milsk, Rebecca Y; DeAngelo, Anthony B; Simmons, Jane Ellen; Moyer, Mary P; Weinberg, Howard S
2014-06-17
As the use of alternative drinking water treatment increases, it is important to understand potential public health implications associated with these processes. The objective of this study was to evaluate the formation of disinfection byproducts (DBPs) and cytotoxicity of natural organic matter (NOM) concentrates treated with chlorine, chloramine, and medium pressure ultraviolet (UV) irradiation followed by chlorine or chloramine, with and without nitrate or iodide spiking. The use of concentrated NOM conserved volatile DBPs and allowed for direct analysis of the treated water. Treatment with UV prior to chlorine in ambient (unspiked) samples did not affect cytotoxicity as measured using an in vitro normal human colon cell (NCM460) assay, compared to chlorination alone when toxicity is expressed on the basis of dissolved organic carbon (DOC). Nitrate-spiked UV+chlorine treatment produced greater cytotoxicity than nitrate-spiked chlorine alone or ambient UV+chlorine samples, on both a DOC and total organic halogen basis. Samples treated with UV+chloramine were more cytotoxic than those treated with only chloramine using either dose metric. This study demonstrated the combination of cytotoxicity and DBP measurements for process evaluation in drinking water treatment. The results highlight the importance of dose metric when considering the relative toxicity of complex DBP mixtures formed under different disinfection scenarios.
Julio, Flores R; Hilario, Terres-Peña; Mabel, Vaca M; Raymundo, López C; Arturo, Lizardi-Ramos; Ma Neftalí, Rojas-Valencia
2015-03-01
The disinfection of a continuous flow of an effluent from an advanced primary treatment (coagulation-flocculation-sedimentation) with or without posterior filtration, using either peracetic acid (PAA) or ultraviolet (UV) radiation was studied. We aimed to obtain bacteriological quality to comply with the microbiological standard established in the Mexican regulations for treated wastewater reuse (NOM-003-SEMARNAT-1997), i.e., less than 240 MPN (most probable number) FC/100 mL. The concentrations of PAA were 10, 15, and 20 mg/L, with contact times of 10, and 15 min. Fecal coliforms (FC) inactivation ranged from 0.93 up to 6.4 log units, and in all cases it reached the limits set by the mentioned regulation. Water quality influenced the PAA disinfection effectiveness. An efficiency of 91% was achieved for the unfiltered effluent, as compared to 99% when wastewater was filtered. UV radiation was applied to wastewater flows of 21, 30 and 39 L/min, with dosages from 1 to 6 mJ/cm². This treatment did not achieve the bacteriological quality required for treated wastewater reuse, since the best inactivation of FC was 1.62 log units, for a flow of 21 L/min of filtered wastewater and a UV dosage of 5.6 mJ/cm².
Disinfection Pilot Trial for Little Miami WWTP | Science ...
There is a serious interest growing nationally towards the use of PAA at various stages of public waste water treatment facilities; one of such use is secondary waste water treatment. MSDGC is currently interested in improving efficiency and economic aspects of waste water treatment. MSDGC requested for ORD’s support to evaluate alternative cost-effective disinfectants. This report herein is based on the data generated from the field pilot test conducted at the Little Miami Wastewater Treatment Plant. Chlorine assisted disinfection of wastewaters created the concern regarding the formation of high levels of toxic halogenated disinfection byproducts (DBPs) detrimental to aquatic life and public health. Peracetic acid is emerging as a green alternative to chlorine and claimed to have economic and social benefits. In addition, it is a relatively simple retrofit to the existing chlorine treated wastewater treatment facilities. PAA is appealed to possess a much lower aquatic toxicity profile than chlorine and decays rapidly in the environment, even if overdosed. As a result, PAA generally does not need a quenching step, such as dechlorination, reducing process complexity, sodium pollution and cost. PAA treatment does not result in the formation of chlorinated disinfection by-products such as trihalomethanes (THMs), haloacetic acids and other byproducts such as cyanide and n-Nitrosodimethylamine (NDMA).
Li, Suqi; Xu, Jing; Chen, Wei; Yu, Yingtan; Liu, Zizheng; Li, Jinjun; Wu, Feng
2016-09-01
p-Arsanilic acid (p-ASA) is widely used in China as livestock and poultry feed additive for promoting animal growth. The use of organoarsenics poses a potential threat to the environment because it is mostly excreted by animals in its original form and can be transformed by UV-Vis light excitation. This work examined the initial rate and efficiency of p-ASA phototransformation under UV-C disinfection lamp. Several factors influencing p-ASA phototransformation, namely, pH, initial concentration, temperature, as well as the presence of NaCl, NH4(+), and humic acid, were investigated. Quenching experiments and LC-MS were performed to investigate the mechanism of p-ASA phototransformation. Results show that p-ASA was decomposed to inorganic arsenic (including As(III) and As(V)) and aromatic products by UV-C light through direct photolysis and indirect oxidation. The oxidation efficency of p-ASA by direct photosis was about 32%, and those by HO and (1)O2 were 19% and 49%, respectively. Cleavage of the arsenic-benzene bond through direct photolysis, HO oxidation or (1)O2 oxidation results in simultaneous formation of inorganic As(III), As(IV), and As(V). Inorganic As(III) is oxidized to As(IV) and then to As(V) by (1)O2 or HO. As(IV) can undergo dismutation or simply react with oxygen to produce As(V) as well. Reactions of the organic moieties of p-ASA produce aniline, aminophenol and azobenzene derivatives as main products. The photoconvertible property of p-ASA implies that UV disinfection of wastewaters from poultry and swine farms containing p-ASA poses a potential threat to the ecosystem, especially agricultural environments. Copyright © 2016. Published by Elsevier B.V.
Miranda, Andreza Costa; Lepretti, Marilena; Rizzo, Luigi; Caputo, Ivana; Vaiano, Vincenzo; Sacco, Olga; Lopes, Wilton Silva; Sannino, Diana
2016-06-01
The release of antibiotics into the environment can result in antibiotic resistance (AR) spread, which in turn can seriously affect human health. Antibiotic resistant bacteria have been detected in different aquatic environments used as drinking water source. Water disinfection may be a possible solution to minimize AR spread but conventional processes, such as chlorination, result in the formation of dangerous disinfection by-products. In this study advanced oxidation processes (AOPs), namely H2O2/UV, TiO2/UV and N-TiO2/UV, have been compared with chlorination in the inactivation of an AR Escherichia coli (E. coli) strain in surface water. TiO2 P25 and nitrogen doped TiO2 (N-TiO2), prepared by sol-gel method at two different synthesis temperatures (0 and -20°C), were investigated in heterogeneous photocatalysis experiments. Under the investigated conditions, chlorination (1.0 mg L(-1)) was the faster process (2.5 min) to achieve total inactivation (6 Log). Among AOPs, H2O2/UV resulted in the best inactivation rate: total inactivation (6 Log) was achieved in 45 min treatment. Total inactivation was not observed (4.5 Log), also after 120 min treatment, only for N-doped TiO2 synthesized at 0°C. Moreover, H2O2/UV and chlorination processes were evaluated in terms of cytotoxicity potential by means of 3-(4,5-dime-thylthiazol-2-yl)-2,5-diphenylte-trazolium colorimetric test on a human-derived cell line and they similarly affected HepG2 cells viability. Copyright © 2016 Elsevier B.V. All rights reserved.
Lizasoain, A; Tort, L F L; García, M; Gillman, L; Alberti, A; Leite, J P G; Miagostovich, M P; Pou, S A; Cagiao, A; Razsap, A; Huertas, J; Berois, M; Victoria, M; Colina, R
2018-03-01
This study assess the quality of wastewater through the detection and quantification of important viruses causing gastroenteritis at different stages of the wastewater treatment process in an activated-sludge wastewater treatment plant with ultraviolet disinfection. Ten sampling events were carried out in a campaign along a period of 18 months collecting wastewater samples from the influent, after the activated-sludge treatment, and after the final disinfection with UV radiation. Samples were concentrated through ultracentrifugation and analysed using retro-transcription, PCR and real time quantitative PCR protocols, for detection and quantification of Group A Rotavirus (RVA), Human Astrovirus (HAstV), Norovirus Genogroup II (NoV GII) and Human Adenovirus (HAdV). HAdV (100%), NoV GII (90%), RVA (70%) and HAstV (60%) were detected in influent samples with concentration from 1·4 (NoV GII) to 8·0 (RVA) log 10 gc l -1 . Activated-sludge treatment reached well quality effluents with low organic material concentration, although nonstatistical significant differences were registered among influent and postactivated sludge treatment samples, regarding the presence and concentration for most viruses. All post-UV samples were negative for NoV GII and HAstV, although RVA and HAdV were detected in 38% and 63% of those samples respectively, with concentration ranging from 2·2 to 5·5 and 3·1 to 3·4 log 10 gc l -1 . This study demonstrates that an activated-sludge wastewater treatment plant with UV disinfection reduces to levels below the detection limit those single-stranded RNA viruses as noroviruses and astroviruses and reach significant lower levels of rotaviruses and adenoviruses after the complete treatment process. © 2017 The Society for Applied Microbiology.
This presentation will focus on validation testing performed on a three-lamp low-pressure high-output (LPHO) TrojanUVSwiftTM UV reactor using MS2, Bacillus Pumilus, and live adenovirus as the test microbes. An adjustable sensor was used to help determine the optimal sensor locati...
Pfeiffer, Valentin; Barbeau, Benoit
2014-02-01
Despite its shortcomings, the T10 method introduced by the United States Environmental Protection Agency (USEPA) in 1989 is currently the method most frequently used in North America to calculate disinfection performance. Other methods (e.g., the Integrated Disinfection Design Framework, IDDF) have been advanced as replacements, and more recently, the USEPA suggested the Extended T10 and Extended CSTR (Continuous Stirred-Tank Reactor) methods to improve the inactivation calculations within ozone contactors. To develop a method that fully considers the hydraulic behavior of the contactor, two models (Plug Flow with Dispersion and N-CSTR) were successfully fitted with five tracer tests results derived from four Water Treatment Plants and a pilot-scale contactor. A new method based on the N-CSTR model was defined as the Partially Segregated (Pseg) method. The predictions from all the methods mentioned were compared under conditions of poor and good hydraulic performance, low and high disinfectant decay, and different levels of inactivation. These methods were also compared with experimental results from a chlorine pilot-scale contactor used for Escherichia coli inactivation. The T10 and Extended T10 methods led to large over- and under-estimations. The Segregated Flow Analysis (used in the IDDF) also considerably overestimated the inactivation under high disinfectant decay. Only the Extended CSTR and Pseg methods produced realistic and conservative predictions in all cases. Finally, a simple implementation procedure of the Pseg method was suggested for calculation of disinfection performance. Copyright © 2013 Elsevier Ltd. All rights reserved.
Solar photocatalytic disinfection with immobilised TiO(2) at pilot-plant scale.
Sordo, Carlos; Van Grieken, Rafael; Marugán, Javier; Fernández-Ibáñez, Pilar
2010-01-01
The photocatalytic disinfection efficiency has been investigated for two immobilized TiO(2) catalytic systems (wall reactor and fixed-bed reactor) in a solar pilot plant. Their performances have been compared with the use of a slurry reactor and the solar disinfection without catalyst. The use of photocatalytic TiO(2) wall reactors does no show clear benefits over the solar disinfection process in the absence of catalyst. The reason is that the efficiency of the solar disinfection is so high that the presence of titania in the reactor wall reduces the global efficiency due to the competition for the absorption of photons. As expected, the maximum efficiency was shown by the slurry TiO(2) reactor, due to the optimum contact between bacteria and catalyst. However, it is noticeable that the use of the fixed-bed reactor leads to inactivation rate quite close to that of the slurry, requiring comparable accumulated solar energy of about 6 kJ L(-1) to achieve a 6-log decrease in the concentration of viable bacteria and allowing a total disinfection of the water (below the detection limit of 1 CFU mL(-1)). Not only the high titania surface area of this configuration is responsible for the bacteria inactivation but the important contribution of the mechanical stress has to be considered. The main advantage of the fixed-bed TiO(2) catalyst is the outstanding stability, without deactivation effects after ten reaction cycles, being readily applicable for continuous water treatment systems.
A systematic experimental study was conducted using a pilot-scale drinking water distribution system simulator to quantify the effect of hydrodynamics, total organic carbon (TOC), initial disinfectant levels, and pipe materials on chlorine decay and disinfection by-product (DBP) ...
A systematic experimental study was conducted using a pilot-scale drinking water distribution system simulator to quantify the effect of hydrodynamics, total organic carbon (TOC), initial disinfectant levels, and pipe materials on chlorine decay and disinfection by-product (DBP) ...
Ultraviolet Light Emitting Diode Optical Power Characterization
2014-03-01
radicals and use the radicals to break down hazardous chemicals. The second project that will be referenced is the drinking water disinfection ...measurements to understand the voltage needed to maximize the UV LEDs performance for the disinfection of drinking water and the production of...way to produce safe drinking water is not only a priority of almost every residential community in the United States, but the Department of Defense
Pilot Study for UVA-LED Disinfection of Escherichia coli in Water for Space and Earth Applications
NASA Technical Reports Server (NTRS)
Ragolta, Carolina
2010-01-01
To test the efficacy of UVA-LED disinfection, a solution of Escherichia coli was pumped through a modified drip flow reactor at a flow rate of 1 ml/min. The experiment was conducted in a controlled environment chamber to ensure that temperature did not cause disinfection. The reactor featured three wells with different treatments: UVA-LED irradiation, UVA-LEDs with Ti02, and UVA-LEDs with nanosilver. Samples from each well were taken throughout a 340 hour period, inactivated, assayed, and analyzed for E. coli disinfection. Results of the duplicate experiments indicated longer exposure times are needed for UVA-LED disinfection of E. coli in water. Further research would consider a longer sampling period and different test conditions, such as increased contact area and various flow rates.
Evaluating UV-C LED disinfection performance and investigating potential dual-wavelength synergy.
Beck, Sara E; Ryu, Hodon; Boczek, Laura A; Cashdollar, Jennifer L; Jeanis, Kaitlyn M; Rosenblum, James S; Lawal, Oliver R; Linden, Karl G
2017-02-01
A dual-wavelength UV-C LED unit, emitting at peaks of 260 nm, 280 nm, and the combination of 260|280 nm together was evaluated for its inactivation efficacy and energy efficiency at disinfecting Escherichia coli, MS2 coliphage, human adenovirus type 2 (HAdV2), and Bacillus pumilus spores, compared to conventional low-pressure and medium-pressure UV mercury vapor lamps. The dual-wavelength unit was also used to measure potential synergistic effects of multiple wavelengths on bacterial and viral inactivation and DNA and RNA damage. All five UV sources demonstrated similar inactivation of E. coli. For MS2, the 260 nm LED was most effective. For HAdV2 and B. pumilus, the MP UV lamp was most effective. When measuring electrical energy per order of reduction, the LP UV lamp was most efficient for inactivating E. coli and MS2; the LP UV and MP UV mercury lamps were equally efficient for HAdV2 and B. pumilus spores. Among the UV-C LEDs, there was no statistical difference in electrical efficiency for inactivating MS2, HAdV2, and B. pumilus spores. The 260 nm and 260|280 nm LEDs had a statistical energy advantage for E. coli inactivation. For UV-C LEDs to match the electrical efficiency per order of log reduction of conventional LP UV sources, they must reach efficiencies of 25-39% or be improved on by smart reactor design. No dual wavelength synergies were detected for bacterial and viral inactivation nor for DNA and RNA damage. Copyright © 2016 Elsevier Ltd. All rights reserved.
Chen, Ting; Xu, Yongpeng; Liu, Zhiquan; Zhu, Shijun; Shi, Wenxin; Cui, Fuyi
2016-04-01
Based on the fact that recycling of combined filter backwash water (CFBW) directly to drinking water treatment plants (WTP) is considered to be a feasible method to enhance pollutant removal efficiency, we were motivated to evaluate the genotoxicity of water samples from two pilot-scale drinking water treatment systems, one with recycling of combined backwash water, the other one with a conventional process. An integrated approach of the comet and micronucleus (MN) assays was used with zebrafish (Danio rerio) to investigate the water genotoxicity in this study. The total organic carbon (TOC), dissolved organic carbon (DOC), and trihalomethane formation potential (THMFP), of the recycling process were lower than that of the conventional process. All the results showed that there was no statistically significant difference (P>0.05) between the conventional and recycling processes, and indicated that the genotoxicity of water samples from the recycling process did not accumulate in 15 day continuous recycling trial. It was worth noting that there was correlation between the concentrations of TOC, DOC, UV254, and THMFPs in water and the DNA damage score, with corresponding R(2) values of 0.68, 0.63, 0.28, and 0.64. Nevertheless, both DNA strand breaks and MN frequency of all water samples after disinfection were higher than that of water samples from the two treatment units, which meant that the disinfection by-products (DBPs) formed by disinfection could increase the DNA damage. Both the comet and MN tests suggest that the recycling process did not increase the genotoxicity risk, compared to the traditional process. Copyright © 2015. Published by Elsevier B.V.
André, Carolina Bosso; Dos Santos, Andressa; Pfeifer, Carmem Silvia; Giannini, Marcelo; Girotto, Emerson Marcelo; Ferracane, Jack Liborio
2018-04-01
This study evaluated three different sterilization/disinfection techniques for resin composites on bacterial growth and surface modification after decontamination. Two resin composites were sterilized/disinfected with three different techniques: UV light, 1% chloramine T, and 70% ethanol. Four different times were used for each technique to determine the shortest time that the solution or UV light was effective. The influence of sterilization/disinfection technique on bacterial growth was evaluated by analyzing the metabolic activity, using the AlamarBlue™ assay, bacterial viability, and SEM images from biofilms of Streptococcus mutans. The surface change, after the process, was analyzed with ATR/FTIR and SEM images. The solutions used for decontamination (1% chloramine-T and 70% ethanol) were analyzed with 1 H-NMR to identify any resin compounds leached during the process. One minute of decontamination was efficient for all three methods tested. Chloramine-T increased the surface porosity on resin composites, no changes were observed for UV light and 70% ethanol, however, 1 H-NMR identified leached monomers only when 70% ethanol was used. No chemical change of the materials was found under ATR/FTIR analyses after the decontamination process. Chloramine-T, with no previous wash, increased the bacterial viability for both resin composites and increased the bacterial metabolism for the resin composite without fluoride. UV light had no interference on the resin composites properties tested using 1 min of exposure compared to the other decontamination methods. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 945-953, 2018. © 2017 Wiley Periodicals, Inc.
Jin, Su-Eon; Hwang, Woochul; Lee, Hyo Jung; Jin, Hyo-Eon
2017-01-01
Metal oxide (MO) nanoparticles have been studied as nano-antibiotics due to their antimicrobial activities even in antibiotic-resistant microorganisms. We hypothesized that a hybrid system of dual UV irradiation and MO nanoparticles would have enhanced antimicrobial activities compared with UV or MO nanoparticles alone. In this study, nanoparticles of ZnO, ZnTiO3, MgO, and CuO were selected as model nanoparticles. A dual UV collimated beam device of UV-A and UV-C was developed depending upon the lamp divided by coating. Physicochemical properties of MO nanoparticles were determined using powder X-ray diffractometry (PXRD), Brunauer-Emmett-Teller analysis, and field emission-scanning electron microscopy with energy-dispersive X-ray spectroscopy. Atomic force microscopy with an electrostatic force microscopy mode was used to confirm the surface topology and electrostatic characteristics after dual UV irradiation. For antimicrobial activity test, MO nanoparticles under dual UV irradiation were applied to Escherichia coli and M13 bacteriophage (phage). The UV-A and UV-C showed differential intensities in the coated and uncoated areas (UV-A, coated = uncoated; UV-C, coated ≪ uncoated). MO nanoparticles showed sharp peaks in PXRD patterns, matched to pure materials. Their primary particle sizes were less than 100 nm with irregular shapes, which had an 8.6~25.6 m2/g of specific surface area with mesopores of 22~262 nm. The electrostatic properties of MO nanoparticles were modulated after UV irradiation. ZnO, MgO, and CuO nanoparticles, except ZnTiO3 nanoparticles, showed antibacterial effects on E. coli. Antimicrobial effects on E. coli and phages were also enhanced after cyclic exposure of dual UV and MO nanoparticle treatment using the uncoated area, except ZnO nanoparticles. Our results demonstrate that dual UV-MO nanoparticle hybrid system has a potential for disinfection. We anticipate that it can be developed as a next-generation disinfection system in pharmaceutical industries and water purification systems. PMID:29138562
Jin, Su-Eon; Hwang, Woochul; Lee, Hyo Jung; Jin, Hyo-Eon
2017-01-01
Metal oxide (MO) nanoparticles have been studied as nano-antibiotics due to their antimicrobial activities even in antibiotic-resistant microorganisms. We hypothesized that a hybrid system of dual UV irradiation and MO nanoparticles would have enhanced antimicrobial activities compared with UV or MO nanoparticles alone. In this study, nanoparticles of ZnO, ZnTiO 3 , MgO, and CuO were selected as model nanoparticles. A dual UV collimated beam device of UV-A and UV-C was developed depending upon the lamp divided by coating. Physicochemical properties of MO nanoparticles were determined using powder X-ray diffractometry (PXRD), Brunauer-Emmett-Teller analysis, and field emission-scanning electron microscopy with energy-dispersive X-ray spectroscopy. Atomic force microscopy with an electrostatic force microscopy mode was used to confirm the surface topology and electrostatic characteristics after dual UV irradiation. For antimicrobial activity test, MO nanoparticles under dual UV irradiation were applied to Escherichia coli and M13 bacteriophage (phage). The UV-A and UV-C showed differential intensities in the coated and uncoated areas (UV-A, coated = uncoated; UV-C, coated ≪ uncoated). MO nanoparticles showed sharp peaks in PXRD patterns, matched to pure materials. Their primary particle sizes were less than 100 nm with irregular shapes, which had an 8.6~25.6 m 2 /g of specific surface area with mesopores of 22~262 nm. The electrostatic properties of MO nanoparticles were modulated after UV irradiation. ZnO, MgO, and CuO nanoparticles, except ZnTiO 3 nanoparticles, showed antibacterial effects on E. coli . Antimicrobial effects on E. coli and phages were also enhanced after cyclic exposure of dual UV and MO nanoparticle treatment using the uncoated area, except ZnO nanoparticles. Our results demonstrate that dual UV-MO nanoparticle hybrid system has a potential for disinfection. We anticipate that it can be developed as a next-generation disinfection system in pharmaceutical industries and water purification systems.
The Wet-Weather Flow Technologies Pilot of the EPA's Environmental Technology Verification (ETV) Program under a partnership with NSF International has verified the performance of the GAS MASTRRR Series 32 Submersible Chemical Induction Mixers used for disinfection of wet-weather...
Safe and Affordable Drinking Water for Developing Countries
NASA Astrophysics Data System (ADS)
Gadgil, Ashok
2008-09-01
Safe drinking water remains inaccessible for about 1.2 billion people in the world, and the hourly toll from biological contamination of drinking water is 200 deaths mostly among children under five years of age. This chapter summarizes the need for safe drinking water, the scale of the global problem, and various methods tried to address it. Then it gives the history and current status of an innovation ("UV Waterworks™") developed to address this major public health challenge. It reviews water disinfection technologies applicable to achieve the desired quality of drinking water in developing countries, and specifically, the limitations overcome by one particular invention: UV Waterworks. It then briefly describes the business model and financing option than is accelerating its implementation for affordable access to safe drinking water to the unserved populations in these countries. Thus this chapter describes not only the innovation in design of a UV water disinfection system, but also innovation in the delivery model for safe drinking water, with potential for long term growth and sustainability.
Dielectric Barrier Discharge based Mercury-free plasma UV-lamp for efficient water disinfection.
Prakash, Ram; Hossain, Afaque M; Pal, U N; Kumar, N; Khairnar, K; Mohan, M Krishna
2017-12-12
A structurally simple dielectric barrier discharge based mercury-free plasma UV-light source has been developed for efficient water disinfection. The source comprises of a dielectric barrier discharge arrangement between two co-axial quartz tubes with an optimized gas gap. The outer electrode is an aluminium baked foil tape arranged in a helical form with optimized pitch, while the inner electrode is a hollow aluminium metallic rod, hermetically sealed. Strong bands peaking at wavelengths 172 nm and 253 nm, along with a weak band peaking at wavelength 265 nm have been simultaneously observed due to plasma radiation from the admixture of xenon and iodine gases. The developed UV source has been used for bacterial deactivation studies using an experimental setup that is an equivalent of the conventional house-hold water purifier system. Deactivation studies for five types of bacteria, i.e., E. coli, Shigella boydii, Vibrio, Coliforms and Fecal coliform have been demonstrated with 4 log reductions in less than ten seconds.
Removal of natural organic matter from drinking water by advanced oxidation processes.
Matilainen, Anu; Sillanpää, Mika
2010-06-01
Over the past 10-20years the amount of the natural organic matter (NOM) has been increased in raw water supplies on several areas. The presence of NOM causes many problems in drinking water treatment processes, including: (i) negative effect on water quality by colour, taste and odor problems, (ii) increased coagulant and disinfectant dose requirements (which in turn results increased sludge and potential harmful disinfection by-product formation), (iii) promoted biological growth in distribution system, and (iv) increased levels of complexed heavy metals and adsorbed organic pollutants. Thus, more efficient methods for the removal of NOM have emerged. Among these are advanced oxidation processes (AOPs). These include O(3)/H(2)O(2), O(3)/UV, UV/H(2)O(2), TiO(2)/UV, H(2)O(2)/catalyst, Fenton and photo-Fenton prosesses as well as ultrasound. In the present work, an overview of the recent research studies dealing with AOP methods for the removal of NOM and related compounds from drinking water is presented.
Bosio, Morgana; Satyro, Suéllen; Bassin, João Paulo; Saggioro, Enrico; Dezotti, Márcia
2018-05-01
Pharmaceutically active compounds are carried into aquatic bodies along with domestic sewage, industrial and agricultural wastewater discharges. Psychotropic drugs, which can be toxic to the biota, have been detected in natural waters in different parts of the world. Conventional water treatments, such as activated sludge, do not properly remove these recalcitrant substances, so the development of processes able to eliminate these compounds becomes very important. Advanced oxidation processes are considered clean technologies, capable of achieving high rates of organic compounds degradation, and can be an efficient alternative to conventional treatments. In this study, the degradation of alprazolam, clonazepam, diazepam, lorazepam, and carbamazepine was evaluated through TiO 2 /UV-A, H 2 O 2 /UV-A, and TiO 2 /H 2 O 2 /UV-A, using sunlight and artificial irradiation. While using TiO 2 in suspension, best results were found at [TiO 2 ] = 0.1 g L -1 . H 2 O 2 /UV-A displayed better results under acidic conditions, achieving from 60 to 80% of removal. When WWTP was used, degradation decreased around 50% for both processes, TiO 2 /UV-A and H 2 O 2 /UV-A, indicating a strong matrix effect. The combination of both processes was shown to be an adequate approach, since removal increased up to 90%. H 2 O 2 /UV-A was used for disinfecting the aqueous matrices, while mineralization was obtained by TiO 2 -photocatalysis.
NASA Astrophysics Data System (ADS)
Bogdan, Janusz; Zarzyńska, Joanna; Pławińska-Czarnak, Joanna
2015-08-01
Nanotechnology contributes towards a more effective eradication of pathogens that have emerged in hospitals, veterinary clinics, and food processing plants and that are resistant to traditional drugs or disinfectants. Since new methods of pathogens eradication must be invented and implemented, nanotechnology seems to have become the response to that acute need. A remarkable achievement in this field of science was the creation of self-disinfecting surfaces that base on advanced oxidation processes (AOPs). Thus, the phenomenon of photocatalysis was practically applied. Among the AOPs that have been most studied in respect of their ability to eradicate viruses, prions, bacteria, yeasts, and molds, there are the processes of TiO2/UV and ZnO/UV. Titanium dioxide (TiO2) and zinc oxide (ZnO) act as photocatalysts, after they have been powdered to nanoparticles. Ultraviolet (UV) radiation is an agent that determines their excitation. Methods using photocatalytic properties of nanosized TiO2 and ZnO prove to be highly efficient in inactivation of infectious agents. Therefore, they are being applied on a growing scale. AOP-based disinfection is regarded as a very promising tool that might help overcome problems in food hygiene and public health protection. The susceptibility of infectious agents to photocatalylic processes can be generally arranged in the following order: viruses > prions > Gram-negative bacteria > Gram-positive bacteria > yeasts > molds.
El Haddad, Lynn; Ghantoji, Shashank S; Stibich, Mark; Fleming, Jason B; Segal, Cindy; Ware, Kathy M; Chemaly, Roy F
2017-10-10
Environmental cleanliness is one of the contributing factors for surgical site infections in the operating rooms (ORs). To decrease environmental contamination, pulsed xenon ultraviolet (PX-UV), an easy and safe no-touch disinfection system, is employed in several hospital environments. The positive effect of this technology on environmental decontamination has been observed in patient rooms and ORs during the end-of-day cleaning but so far, no study explored its feasibility between surgical cases in the OR. In this study, 5 high-touch surfaces in 30 ORs were sampled after manual cleaning and after PX-UV intervention mimicking between-case cleaning to avoid the disruption of the ORs' normal flow. The efficacy of a 1-min, 2-min, and 8-min cycle were tested by measuring the surfaces' contaminants by quantitative cultures using Tryptic Soy Agar contact plates. We showed that combining standard between-case manual cleaning of surfaces with a 2-min cycle of disinfection using a portable xenon pulsed ultraviolet light germicidal device eliminated at least 70% more bacterial load after manual cleaning. This study showed the proof of efficacy of a 2-min cycle of PX-UV in ORs in eliminating bacterial contaminants. This method will allow a short time for room turnover and a potential reduction of pathogen transmission to patients and possibly surgical site infections.
UV Waterworks Outreach Support. Final Report
DOE R&D Accomplishments Database
Miller, P.
1998-05-01
A recently invented device uses UV light (254 nm) to inexpensively disinfect community drinking water supplies. Its novel features are: low cost (about US $600), robust design, rapid disinfection (12 seconds), low electricity use (40W), low maintenance (every 6 months), high flow rate (15 l/min) and ability to work with unpressurized water sources. The device could service a community of 1,000 persons, at an annual total cost of 14 cents US per person. This device has been tested in a number of independent laboratories worldwide. The laboratory tests have confirmed that the unit is capable of disinfecting waters to drinking water standards for bacteria and viruses. An extended field trial of the device began in South Africa in February 1997, with lab testing at the municipal water utility. A unit installed at the first field site, an AIDS hospice near Durban, has been in continuous operation since August, 1997. Additional test sites are being identified. The author describes the results of the initial lab tests, reports the most recent findings from the ongoing field test-monitoring program, and discusses plans for future tests.
Water ingestion during swimming activities in a pool: a pilot study.
Dufour, Alfred P; Evans, Otis; Behymer, Thomas D; Cantú, Ricardo
2006-12-01
Chloroisocyanurates are commonly added to outdoor swimming pools to stabilize chlorine disinfectants. The chloroisocyanurates decompose slowly to release chlorine and cyanuric acid. Studies conducted to determine if the chloroisocyanurates might be toxic to swimmers showed that they were not and that ingested cyanuric acid passed through the body unmetabolized. This fact was used to determine the amount of water swallowed during swimming activity. Fifty-three recreational swimmers, using a community swimming pool disinfected with cyanuric acid stabilized chlorine, participated in the study. The participants did not swim on the day before or after the test swim. The swimmers were asked to actively swim for at least 45 minutes and to collect their urine for the next 24 hours. Cyanuric acid was measured in pool water using high performance liquid chromatography and porous graphitic carbon columns with UV detection. The urine sample assay required a clean-up procedure to remove urinary proteins and interfering substances. Results of the study indicate that non-adults ingest about twice as much water as adults during swimming activity. The average amount of water swallowed by non-adults and adults was 37 ml and 16 ml, respectively. The design for this study and the analytical methodology used to assay cyanuric acid in swimming pool water and human urine were effective for measuring the volume of water swallowed during swimming activity.
Haaken, Daniela; Dittmar, Thomas; Schmalz, Viktor; Worch, Eckhard
2014-04-01
Reuse of wastewater contributes significantly to an efficient and sustainable water usage. However, due to the presence of a multitude of pathogens (e.g. bacteria, viruses, worms, protozoa) in secondary effluents, disinfection procedures are indispensable. In decentralized wastewater treatment, UV irradiation represents one of the most common disinfection methods in addition to membrane processes and to a certain extent electrochemical procedures. However, the usage of UV disinfected secondary effluents for domestic (sanitary) or irrigation purposes bears a potential health risk due to the possible photo and dark repair of reversibly damaged bacteria. Against this background, the application of the UV/electrolysis hybrid technology for disinfection and prevention of bacterial reactivation in biologically treated wastewater was investigated in view of relevant influence factors and operating limits. Furthermore, the influence of electrochemically generated total oxidants on the formation of biofilms on quartz glass surfaces was examined, since its preventive avoidance contributes to an enhanced operational safety of the hybrid reactor. It was found that reactivation of bacteria in UV irradiated, biologically treated wastewater can be prevented by electrochemically produced total oxidants. In this regard, the influence of the initial concentration of the microbiological indicator organism Escherichia coli (E. coli) (9.3*10(2)-2.2*10(5) per 100 mL) and the influence of total suspended solids (TSS) in the range of 11-75 mg L(-1) was examined. The concentration of total oxidants necessary for prevention of bacterial regrowth increases linearly with the initial E. coli and TSS concentration. At an initial concentration of 933 E. coli per 100 mL, a total oxidants concentration of 0.4 mg L(-1) is necessary to avoid photo reactivation (at 4200 Lux), whereas 0.67 mg L(-1) is required if the E. coli concentration is enhanced by 2.4 log levels (cTSS = constant = 13 mg L(-1)). The prevention of dark repair is ensured with 25-50% lower concentration of total oxidants. An increase of the TSS concentration from 11 mg L(-1) to 75 mg L(-1) leads to a triplication of the need of total oxidants from 0.6 mg L(-1) to 1.8 mg L(-1) (3*10(5)E. coli per 100 mL). The energy consumption of the hybrid reactor varies from 0.17 kWh m(-3) to 0.94 kWh m(-3) depending on the TSS concentration (11-75 mg L(-1)). Furthermore, biofilm formation on quartz glass surfaces, of which the sleeves of UV lamps consist, can be suppressed by electrochemically produced total oxidants at a concentration of at least 1 mg L(-1) which ensures high operational safety of the hybrid reactor combined with large maintenance intervals. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Hidayah, E. N.; Yeh, H. H.
2018-01-01
Laboratory scale experiments was conducted to examine effect of permanganate (KMnO4) peroxidation in characterizing and to remove natural organic matter (NOM) in source water. The experimental results shows that increasing permanganate dosage could decreased aromatic matter, as indicated by decreasing UV254 and SUVA value about 23% and 28%, respectively. It seems that permanganate preoxidation caused the breakdown of high molecular weight (MW) organics into low MW ones, as represented by increasing NPDOC about 10%. Further, disinfection by-products formation potential (DBPFP) in terms of trihalomethanes formation potential (THMFP) and haloacetic acid formation potential (HAAP) decreased about 15% and 23%, respectively. HAAFP removal is higher than THMFP removal and that DPBFP removal is consistent with UV254 and NPDOC removal.
Natural organic matters removal efficiency by coagulation
NASA Astrophysics Data System (ADS)
Sapingi, Mohd Sharizal Mohd; Pishal, Munirah; Murshed, Mohamad Fared
2017-10-01
The presence of Natural Organic Matter (NOM) in surface water results in unwanted characteristics in terms of color, odor, and taste. NOM content reaction with free chlorine in treated water lowers the water quality further. Chlorine is added for disinfection and produces undesirable disinfection by-products (DPBs). DBPs in drinking water are carcinogenic to consumers and may promote cancerous cell development in the human body. This study was performed to compare the coagulant efficiency of aluminum sulfate (Alum) and ferric chloride (FeCl3) on NOM removal (as in UV254 absorbance) and turbidity removal under three pH conditions (pH 6, pH 7, and sample actual pH). The three sampling points for these studies were Jalan Baru River, Kerian River, and Redac Pond. Additional sampling points, such as Lubuk Buntar and a tubewell located in the Civil Engineering School, were included to observe differences in characteristics. DOC, UV absorbance, and full wavelength were tested, after which samples treated with alum were also tested to further analyze the NOM content. Based on UV254 absorbance and DOC data, specific UV value was calculated to obtain vital synopsis of the characteristics of NOM content, as well as coagulation efficiency.
Surface disinfection by exposure to germicidal UV light.
Katara, G; Hemvani, N; Chitnis, S; Chitnis, V; Chitnis, D S
2008-01-01
The present study was aimed to design a simple model to check efficacy of germicidal UV tube, to standardise the position, distance and time for UV light and also to find out its efficacy against medically important bacteria, the bacterial spores and fungi. The microbial cultures tested included gram positive and gram negative bacteria, bacterial spores and fungal spores. The microbes streaked on solid media were exposed to UV light. The inactivation of the order of four logs was observed for bacteria. UV light can have efficient inactivation of bacteria up to a distance of eight feet on either side and exposure time of 30 minutes is adequate.
Ultraviolet Radiation Dose National Standard of México
NASA Astrophysics Data System (ADS)
Cardoso, R.; Rosas, E.
2006-09-01
We present the Ultraviolet (UV) Radiation Dose National Standard for México. The establishment of this measurement reference at Centro Nacional de Metrología (CENAM) eliminates the need of contacting foreign suppliers in the search for traceability towards the SI units when calibrating instruments at 365 nm. Further more, the UV Radiation Dose National Standard constitutes a highly accurate and reliable source for the UV radiation dose measurements performed in medical and cosmetic treatments as in the the food and pharmaceutics disinfection processes, among other.
The Wet-Weather Flow Technologies Pilot of the EPA's Technology Verification (ETV) Program under a partnership with NSF International has verified the performawnce of the USFilter/Stranco Products chemical induction mixer used for disinfection of wet-weather flows. The USFilter t...
Cervero-Aragó, Sílvia; Sommer, Regina; Araujo, Rosa M
2014-12-15
Water systems are the primary reservoir for Legionella spp., where the bacteria live in association with other microorganisms, such as free-living amoebae. A wide range of disinfection treatments have been studied to control and prevent Legionella colonization but few of them were performed considering its relation with protozoa. In this study, the effectiveness of UV irradiation (253.7 nm) using low-pressure lamps was investigated as a disinfection method for Legionella and amoebae under controlled laboratory conditions. UV treatments were applied to 5 strains of Legionella spp., 4 strains of free-living amoeba of the genera Acanthamoeba and Vermamoeba, treating separately trophozoites and cysts, and to two different co-cultures of Legionella pneumophila with the Acanthamoeba strains. No significant differences in the UV inactivation behavior were observed among Legionella strains tested which were 3 logs reduced for fluences around 45 J/m(2). UV irradiation was less effective against free-living amoebae; which in some cases required up to 990 J/m(2) to obtain the same population reduction. UV treatment was more effective against trophozoites compared to cysts; moreover, inactivation patterns were clearly different between the genus Acanthamoeba and Vermamoeba. For the first time data about Vermamoeba vermiformis UV inactivation has been reported in a study. Finally, the results showed that the association of L. pneumophila with free-living amoebae decreases the effectiveness of UV irradiation against the bacteria in a range of 1.5-2 fold. That fact demonstrates that the relations established between different microorganisms in the water systems can modify the effectiveness of the UV treatments applied. Copyright © 2014 Elsevier Ltd. All rights reserved.
Nourmoradi, H; Nikaeen, M; Stensvold, C R; Mirhendi, H
2012-11-15
Invasive aspergillosis is the second most common cause of nosocomial fungal infections and occurring mainly by Aspergillus fumigatus, Aspergillus flavus, and Aspergillus niger. There is evidence that nosocomial aspergillosis may be waterborne. This study was conducted to evaluate the ultraviolet (UV) irradiation efficiency in terms of inactivating the most important Aspergillus species in water since these are potential sources for nosocomial aspergillosis. A continuous flow UV reactor which could be used as a point-of-use (POU) system was used to survey Aspergillus inactivation by UV irradiation. The inactivation efficiency of UV fluence (4.15-25 mJ/cm(2)) was measured by determination of fungal density in water before and after radiation. Because turbidity and iron concentration are two major water quality factors impacting UV disinfection effectiveness, the potential influence of these factors on UV inactivation of Aspergillus spp. was also measured. The 4 log inactivation for A. fumigatus, A. niger and A. flavus at a density of 1000 cfu/ml was achieved at UV fluences of 12.45 mJ/cm(2), 16.6 mJ/cm(2) and 20.75 mJ/cm(2), respectively. The inactivation efficiency for lower density (100 cfu/ml) was the same as for the higher density except for A. flavus. The removal efficiency of Aspergillus spp. was decreased by increasing the turbidity and iron concentration. UV disinfection could effectively inactivate Aspergillus spores from water and eliminate potential exposure of high-risk patients to fungal aerosols by installation of POU UV systems. Copyright © 2012 Elsevier Ltd. All rights reserved.
UV-induced transformation of four halobenzoquinones in drinking water.
Qian, Yichao; Wang, Wei; Boyd, Jessica M; Wu, Minghuo; Hrudey, Steve E; Li, Xing-Fang
2013-05-07
Halobenzoquinones (HBQs) are a group of emerging disinfection byproducts (DBPs) found in treated drinking water. Because the use of UV treatment for disinfection is becoming more widespread, it is important to understand how the HBQs may be removed or changed due to UV irradiation. Water samples containing four HBQs, 2,6-dichloro-1,4-benzoquinone (DCBQ), 2,3,6-trichloro-1,4-benzoquinone (TCBQ), 2,6-dichloro-3-methyl-1,4-benzoquinone (DCMBQ), and 2,6-dichloro-1,4-benzoquinone (DBBQ), were treated using a modified bench scale collimated beam device, mimicking UV treatment. Water samples before and after UV irradiation were analyzed for the parent compounds and products using a high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) method. As much as 90% of HBQs (0.25 nmol L(-1)) in both pure water and tap water were transformed to other products after UV254 irradiation at 1000 mJ cm(-2). The major products of the four HBQs were identified as 3-hydroxyl-2,6-dichloro-1,4-benzoquinone (OH-DCBQ) from DCBQ, 5-hydroxyl-2,6-dichloro-3-methyl-1,4-benzoquinone (OH-DCMBQ) from DCMBQ, 5-hydroxyl-2,3,6-trichloro-1,4-benzoquinone (OH-TCBQ) from TCBQ, and 3-hydroxyl-2,6-dibromo-1,4-benzoquinone (OH-DBBQ) from DBBQ. These four OH-HBQs were further modified to monohalogenated benzoquinones when the UV dose was higher than 200 mJ cm(-2). These results suggested possible pathways of UV-induced transformation of HBQs to other compounds. Under the UV dose commonly used in water treatment plants, it is likely that HBQs are partially converted to other halo-DBPs. The occurrence and toxicity of these mixed DBPs warrant further investigation to understand whether they pose a health risk.
Zhang, Shujuan; Wang, Xiaomao; Yang, Hongwei; Xie, Yuefeng F
2016-07-01
UV filters are a kind of emerging contaminant, and their transformation behavior in water treatment processes has aroused great concern. In particular, toxic products might be produced during reaction with disinfectants during the disinfection process. As one of the most widely used UV filters, oxybenzone has received significant attention, because its transformation and toxicity changes during chlorine oxidation are a concern. In our study, the reaction between oxybenzone and chlorine followed pseudo-first-order and second-order kinetics. Three transformation products were detected by LC-MS/MS, and the stability of products followed the order of tri-chloro-methoxyphenoyl > di-chlorinated oxybenzone > mono-chlorinated oxybenzone. Disinfection byproducts (DBPs) including chloroform, trichloroacetic acid, dichloroacetic acid and chloral hydrate were quickly formed, and increased at a slower rate until their concentrations remained constant. The maximum DBP/oxybenzone molar yields for the four compounds were 12.02%, 6.28%, 0.90% and 0.23%, respectively. SOS/umu genotoxicity test indicated that genotoxicity was highly elevated after chlorination, and genotoxicity showed a significantly positive correlation with the response of tri-chloro-methoxyphenoyl. Our results indicated that more genotoxic transformation products were produced in spite of the elimination of oxybenzone, posing potential threats to drinking water safety. This study shed light on the formation of DBPs and toxicity changes during the chlorination process of oxybenzone. Copyright © 2016 Elsevier Ltd. All rights reserved.
Chu, Wen-Hai; Gao, Nai-Yun; Templeton, Michael R; Yin, Da-Qiang
2011-04-01
The formation of disinfection by-products (DBPs), including both nitrogenous disinfection by-products (N-DBPs) and carbonaceous disinfection by-products (C-DBPs), was investigated upon chlorination of water samples following two treatment processes: (i) coagulation-inclined plate sedimentation (IPS)-filtration and (ii) coagulation-dissolved air flotation (DAF)-filtration. The removal of algae, dissolved organic nitrogen (DON), dissolved organic carbon (DOC) and UV(254) by coagulation-DAF-filtration was superior to coagulation-IPS-filtration. On average, 53%, 53% and 31% of DOC, DON and UV(254) were removed by coagulation-DAF-filtration process, which were higher than 47%, 31% and 27% of that by coagulation-IPS-filtration process. Additionally, coagulation-IPS-filtration performed less well at removing the low molecular weight organics than coagulation-DAF-filtration process. The concentrations of chloroform, dichloroacetamide (DCAcAm) and dichloroacetonitrile (DCAN) formed during chlorination after coagulation-DAF-filtration reached their maximum values of 13, 1.5 and 4.7μgL(-1), respectively, and were lower than those after coagulation-IPS-filtration with the maximum detected levels of 17, 2.9 and 6.3μgL(-1). However, the trichloronitromethane (TCNM) concentration after the two processes was similar, suggesting that DON may have less of a contribution to TCNM formation than DCAcAm and DCAN. Copyright © 2011 Elsevier Ltd. All rights reserved.
Wait, Isaac W; Johnston, Cliff T; Blatchley, Ernest R
2007-06-01
Ultraviolet (UV) disinfection systems are incorporated into drinking water production facilities because of their broad-spectrum antimicrobial capabilities, and the minimal disinfection by-product formation that generally accompanies their use. Selection of an optimal location for a UV system within a drinking water treatment facility depends on many factors; a potentially important consideration is the effect of system location on operation and maintenance issues, including the potential for fouling of quartz surfaces. To examine the effect of system location on fouling, experiments were conducted at a groundwater treatment facility, wherein aeration, chlorination, and sand filtration were applied sequentially for treatment. In this facility, access to the water stream was available prior to and following each of the treatment steps. Therefore, it was possible to examine the effects of each of these unit operations on fouling dynamics within a UV system. Results indicated zero-order formation kinetics for the fouling reactions at all locations. Increases in oxidation reduction potential, caused by water treatment steps such as aeration and chlorination, increased the rate of sleeve fouling and the rate of irradiance loss within the reactor. Analysis of metals in the sleeve foulant showed that calcium and iron predominate, and relative comparisons of foulant composition to water chemistry highlighted a high affinity for incorporation into the foulant matrix for both iron and manganese, particularly after oxidizing treatment steps. Fouling behavior was observed to be in qualitative agreement with representations of the degree of saturation, relative to the metal:ligand combinations that are believed to comprise a large fraction of the foulants that accumulate on the surfaces of quartz jackets in UV systems used to treat water.
Gondal, Mohammed A; Khalil, Amjad
2008-04-01
Laser-induced photo-catalysis process using WO(3) semiconductor catalyst was applied for the study of disinfection effectiveness of E-coliform-contaminated water. For this purpose, wastewater polluted with E-coliform bacteria was exposed to 355 nm UV radiations generated by third harmonic of Nd: YAG laser in special glass cell with and without WO(3) catalyst. E-Coliform quantification was performed by direct plating method to obtain the efficiency of each disinfection treatment. The dependence of disinfection process on laser irradiation energy, amount of catalyst and duration of laser irradiation was also investigated. The disinfection with WO(3) was quite efficient inactivating E-coliforms. For inactivation of E-coliforms, less than 8 minutes' laser irradiation was required, so that, the treated water complies with the microbial standards for drinking water. This study opens the possibility of application of this simple method in rural areas of developing countries using solar radiation.
One plunge or two?--hand disinfection with alcohol gel.
Macdonald, Duncan J M; Mckillop, Elisabeth C A; Trotter, Sylvia; Gray, Alastair J R
2006-04-01
To compare health care workers' hand surface coverage using two different volumes of alcohol gel for hand disinfection. and methods. A total of 84 members of staff in our hospital were studied. Subjects were asked to disinfect their hands with alcohol gel containing a clear fluorescent substance. Performance was assessed by using UV light to identify areas which had been missed, and the total surface area missed was calculated. A total of 42 subjects received 3.5 ml of alcohol gel, and 42 age-, sex-, and job-matched subjects received 1.75 ml of alcohol gel. Significantly less area was missed when hand disinfecting with double the volume of alcohol gel; 1.23 versus 6.35% surface area was missed (P < 0.001). Doubling the volume of alcohol gel used for hand disinfection significantly improves the efficiency of coverage of the hands with alcohol gel. This may result in lower bacterial count on the hands and may reduce the spread of nosocomial infections including that of methicillin-resistant Staphylococcus aureus.
Gehr, Ronald; Wagner, Monika; Veerasubramanian, Priya; Payment, Pierre
2003-11-01
The City of Montreal Wastewater Treatment Plant uses enhanced physicochemical processes (ferric and/or alum coagulation) for suspended solids and phosphorus removal. The objective of this study was to assess the ability of peracetic acid (PAA), UV, or ozone to inactivate the indicator organisms fecal coliforms, Enterococci, MS-2 coliphage, or Clostridium perfringens in the effluent from this plant. PAA doses to reach the target fecal coliform level of 9000 CFU/100mL exceeded 6 mg/L; similar results were obtained for enterococci, and no inactivation of Clostridium perfringens was observed. However a 1-log reduction of MS-2 occurred at PAA doses of 1.5 mg/L and higher. It was expected that this effluent would have a high ozone demand, and would require relatively high UV fluences, because of relatively high effluent COD, iron and suspended solids concentrations, and low UV transmittance. This was confirmed herein. For UV, the inactivation curve for fecal coliforms showed the typical two-stage shape, with the target of 1000 CFU/100 mL (to account for photoreactivation) occurring in the asymptote zone at fluences >20 mJ/cm(2). In contrast, inactivation curves for MS-2 and Clostridium perfringens were linear. Clostridium perfringens was the most resistant organism. For ozone, inactivation was already observed before any residuals could be measured. The transferred ozone doses to reach target fecal coliform levels ( approximately 2-log reduction) were 30-50 mg/L. MS-2 was less resistant, but Clostridium perfringens was more resistant than fecal coliforms. The different behaviour of the four indicator organisms studied, depending on the disinfectant, suggests that a single indicator organism might not be appropriate. The required dose of any of the disinfectants is unlikely to be economically viable, and upstream changes to the plant will be needed.
Turbidity composition and the relationship with microbial attachment and UV inactivation efficacy.
Farrell, Charlotte; Hassard, Francis; Jefferson, Bruce; Leziart, Tangui; Nocker, Andreas; Jarvis, Peter
2018-05-15
Turbidity in water can be caused by a range of different turbidity causing materials (TCM). Here the characteristics and attachment of bacteria to TCMs was assessed and the resultant impact on UV disinfection determined. TCMs represent potential vehicles for bacterial penetration of water treatment barriers, contamination of potable supplies and impact on subsequent human health. The TCMs under investigation were representative of those that may be present in surface and ground waters, both from the source and formed in the treatment process. The TCMs were chalk, Fe (III) hydroxide precipitate, kaolin clay, manganese dioxide and humic acids, at different turbidity levels representative of source waters (0, 0.1, 0.2, 0.4, 1, 2, and 5 NTU). Escherichia coli and Enterococcus faecalis attachment followed the order of Fe(III)>chalk, with little to no attachment seen for MnO 2 , humic acids and clay. The attachment was postulated to be due to chalk and Fe(III) particles having a more neutral surface charge resulting in elevated aggregation with bacteria compared to other TCMs. The humic acids and Fe(III) were the TCMs which influenced inactivation of E. coli and E. faecalis due to decreasing UV transmittance (UVT) with increasing TCM concentration. The presence of the Fe(III) TCM at 0.2 NTU resulted in the poorest E. coli inactivation, with 2.5 log 10 reduction at UV dose of 10mJcm -2 (k d of -0.23cm 2 mJ -1 ) compared to a 3.9 log 10 reduction in the absence of TCMs. E. faecalis had a greater resistance to UV irradiation than E. coli for all TCMs. Effective disinfection of drinking water is a priority for ensuring high public health standards. Uniform regulations for turbidity levels for waters pre-disinfection by UV light set by regulators may not always be appropriate and efficacy is dependent on the type, as well as the amount, of turbidity present in the water. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
Chen, Hong; Zhang, Mingmei
2013-08-06
This study aimed at quantifying the concentration and removal of antibiotic resistance genes (ARGs) in three municipal wastewater treatment plants (WWTPs) employing different advanced treatment systems [biological aerated filter, constructed wetland, and ultraviolet (UV) disinfection]. The concentrations of tetM, tetO, tetQ, tetW, sulI, sulII, intI1, and 16S rDNA genes were examined in wastewater and biosolid samples. In municipal WWTPs, ARG reductions of 1-3 orders of magnitude were observed, and no difference was found among the three municipal WWTPs with different treatment processes (p > 0.05). In advanced treatment systems, 1-3 orders of magnitude of reductions in ARGs were observed in constructed wetlands, 0.6-1.2 orders of magnitude of reductions in ARGs were observed in the biological aerated filter, but no apparent decrease by UV disinfection was observed. A significant difference was found between constructed wetlands and biological filter (p < 0.05) and between constructed wetlands and UV disinfection (p < 0.05). In the constructed wetlands, significant correlations were observed in the removal of ARGs and 16S rDNA genes (R(2) = 0.391-0.866; p < 0.05). Constructed wetlands not only have the comparable ARG removal values with WWTP (p > 0.05) but also have the advantage in ARG relative abundance removal, and it should be given priority to be an advanced treatment system for further ARG attenuation from WWTP.
A new UV-LED device for automatic disinfection of stethoscope membranes.
Messina, Gabriele; Burgassi, Sandra; Messina, Daniele; Montagnani, Valerio; Cevenini, Gabriele
2015-10-01
Stethoscopes are widely used by doctors and nurses. Poor stethoscope hygiene is a potential source of nosocomial infection. This study aimed to propose an innovative solution, based on the latest advances in ultraviolet (UV) light-emitting diodes (LEDs), for disinfecting stethoscope membranes automatically and efficiently. Staphylococcus aureus, Escherichia coli, Pseudomonas aeruginosa, and Enterococcus faecalis were sown on 28 stethoscope membranes and then transferred to Petri dishes. Treatment involved illuminating exposed Petri dishes with a UVC LED for 1 minute. For each microbe, the number of colony-forming units (cfu) at 36°C was compared in control and treated dishes using the Wilcoxon signed-rank test. The Kruskal-Wallis test was used to assess percent reductions in bacteria. Statistical significance was set at 99%. A significant reduction in cfu counts after UV treatment (P < .01) was found for all bacteria: 85.5% for E faecalis, 87.5% for S aureus, 94.3% for E coli, and 94.9% for P aeruginosa . No significant differences in percent reduction in cfu were found between bacteria (P > .01). The stethoscope, symbol of medicine and health care professionals, has been demonstrated to be a carrier of microorganisms. The treatment technique was effective and efficient in disinfecting the membranes. These promising results represent a step forward toward eliminating stethoscope membrane contamination with an innovative approach. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Kolkman, Annemieke; Martijn, Bram J; Vughs, Dennis; Baken, Kirsten A; van Wezel, Annemarie P
2015-04-07
Advanced oxidation processes are important barriers for organic micropollutants (e.g., pharmaceuticals, pesticides) in (drinking) water treatment. Studies indicate that medium pressure (MP) UV/H2O2 treatment leads to a positive response in Ames mutagenicity tests, which is then removed after granulated activated carbon (GAC) filtration. The formed potentially mutagenic substances were hitherto not identified and may result from the reaction of photolysis products of nitrate with (photolysis products of) natural organic material (NOM). In this study we present an innovative approach to trace the formation of disinfection byproducts (DBPs) of MP UV water treatment, based on stable isotope labeled nitrate combined with high resolution mass spectrometry. It was shown that after MP UV treatment of artificial water containing NOM and nitrate, multiple nitrogen containing substances were formed. In total 84 N-DBPs were detected at individual concentrations between 1 to 135 ng/L bentazon-d6 equivalents, with a summed concentration of 1.2 μg/L bentazon-d6 equivalents. The chemical structures of three byproducts were confirmed. Screening for the 84 N-DBPs in water samples from a full-scale drinking water treatment plant based on MP UV/H2O2 treatment showed that 22 of the N-DBPs found in artificial water were also detected in real water samples.
De Sanctis, Marco; Del Moro, Guido; Levantesi, Caterina; Luprano, Maria Laura; Di Iaconi, Claudio
2016-02-01
In the present paper, the effectiveness of a Sequencing Batch Biofilter Granular Reactor (SBBGR) and its integration with different disinfection strategies (UV irradiation, peracetic acid) for producing an effluent suitable for agricultural use was evaluated. The plant treated raw domestic sewage, and its performances were evaluated in terms of the removal efficiency of a wide group of physical, chemical and microbiological parameters. The SBBGR resulted really efficient in removing suspended solids, COD and nitrogen with an average effluent concentration of 5, 32 and 10 mg/L, respectively. Lower removal efficiency was observed for phosphorus with an average concentration in the effluent of 3 mg/L. Plant effluent was also characterized by an average electrical conductivity and sodium adsorption ratio of 680 μS/cm and 2.9, respectively. Therefore, according to these gross parameters, the SBBGR effluent was conformed to the national standards required in Italy for agricultural reuse. Moreover, disinfection performances of the SBBGR was higher than that of conventional municipal wastewater treatment plants and met the quality criteria suggested by WHO (Escherichia coli<1000 CFU/100 mL) for agricultural reuse. In particular, the biological treatment by SBBGR removed 3.8±0.4 log units of Giardia lamblia, 2.8±0.8 log units of E. coli, 2.5±0.7 log units of total coliforms, 2.0±0.3 log units of Clostridium perfringens, 2.0±0.4 log units of Cryptosporidium parvum and 1.7±0.7 log units of Somatic coliphages. The investigated disinfection processes (UV and peracetic acid) resulted very effective for total coliforms, E. coli and somatic coliphages. In particular, a UV radiation and peracetic acid doses of 40 mJ/cm(2) and 1 mg/L respectively reduced E. coli content in the effluent below the limit for agricultural reuse in Italy (10 CFU/100 mL). Conversely, they were both ineffective on C.perfringens spores. Copyright © 2015 Elsevier B.V. All rights reserved.
Omotade, T O; Bernhards, R C; Klimko, C P; Matthews, M E; Hill, A J; Hunter, M S; Webster, W M; Bozue, J A; Welkos, S L; Cote, C K
2014-12-01
Decontamination and remediation of a site contaminated by the accidental or intentional release of fully virulent Bacillus anthracis spores are difficult, costly and potentially damaging to the environment. Development of novel decontamination strategies that have minimal environmental impacts remains a high priority. Although ungerminated spores are amongst the most resilient organisms known, once exposed to germinants, the germinating spores, in some cases, become susceptible to antimicrobial environments. We evaluated the concept that once germinated, B. anthracis spores would be less hazardous and significantly easier to remediate than ungerminated dormant spores. Through in vitro germination and sensitivity assays, we demonstrated that upon germination, B. anthracis Ames spores and Bacillus thuringiensis Al Hakam spores (serving as a surrogate for B. anthracis) become susceptible to environmental stressors. The majority of these germinated B. anthracis and B. thuringiensis spores were nonviable after exposure to a defined minimal germination-inducing solution for prolonged periods of time. Additionally, we examined the impact of potential secondary disinfectant strategies including bleach, hydrogen peroxide, formaldehyde and artificial UV-A, UV-B and UV-C radiation, employed after a 60-min germination-induction step. Each secondary disinfectant employs a unique mechanism of killing; as a result, germination-induction strategies are better suited for some secondary disinfectants than others. These results provide evidence that the deployment of an optimal combination strategy of germination-induction/secondary disinfection may be a promising aspect of wide-area decontamination following a B. anthracis contamination event. By inducing spores to germinate, our data confirm that the resulting cells exhibit sensitivities that can be leveraged when paired with certain decontamination measures. This increased susceptibility could be exploited to devise more efficient and safe decontamination measures and may obviate the need for more stringent methods that are currently in place. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.
Francy, Donna S; Stelzer, Erin A; Bushon, Rebecca N; Brady, Amie M G; Williston, Ashley G; Riddell, Kimberly R; Borchardt, Mark A; Spencer, Susan K; Gellner, Terry M
2012-09-01
Log removals of bacterial indicators, coliphage, and enteric viruses were studied in three membrane bioreactor (MBR) activated-sludge and two conventional secondary activated-sludge municipal wastewater treatment plants during three recreational seasons (May-Oct.) when disinfection of effluents is required. In total, 73 regular samples were collected from key locations throughout treatment processes: post-preliminary, post-MBR, post-secondary, post-tertiary, and post-disinfection (UV or chlorine). Out of 19 post-preliminary samples, adenovirus by quantitative polymerase chain reaction (qPCR) was detected in all 19, enterovirus by quantitative reverse transcription polymerase chain reaction (qRT-PCR) was detected in 15, and norovirus GI by qRT-PCR was detected in 11. Norovirus GII and Hepatitis A virus were not detected in any samples, and rotavirus was detected in one sample but could not be quantified. Although culturable viruses were found in 12 out of 19 post-preliminary samples, they were not detected in any post-secondary, post-MBR, post-ultraviolet, or post-chlorine samples. Median log removals for all organisms were higher for MBR secondary treatment (3.02 to >6.73) than for conventional secondary (1.53-4.19) treatment. Ultraviolet disinfection after MBR treatment provided little additional log removal of any organism except for somatic coliphage (>2.18), whereas ultraviolet or chlorine disinfection after conventional secondary treatment provided significant log removals (above the analytical variability) of all bacterial indicators (1.18-3.89) and somatic and F-specific coliphage (0.71 and >2.98). Median log removals of adenovirus across disinfection were low in both MBR and conventional secondary plants (no removal detected and 0.24), and few removals of individual samples were near or above the analytical variability of 1.2 log genomic copies per liter. Based on qualitative examinations of plots showing reductions of organisms throughout treatment processes, somatic coliphage may best represent the removal of viruses across secondary treatment in both MBR and conventional secondary plants. F-specific coliphage and Escherichia coli may best represent the removal of viruses across the disinfection process in MBR facilities, but none of the indicators represented the removal of viruses across disinfection in conventional secondary plants. Published by Elsevier Ltd.
Francy, Donna S.; Erin, A. Stelzer; Bushon, Rebecca N.; Brady, Amie M.G.; Williston, Ashley G.; Riddell, Kimberly R.; Borchardt, Mark A.; Spencer, Susan K.; Gellner, Terry M.
2012-01-01
Log removals of bacterial indicators, coliphage, and enteric viruses were studied in three membrane bioreactor (MBR) activated-sludge and two conventional secondary activated-sludge municipal wastewater treatment plants during three recreational seasons (May-Oct.) when disinfection of effluents is required. In total, 73 regular samples were collected from key locations throughout treatment processes: post-preliminary, post-MBR, post-secondary, post-tertiary, and post-disinfection (UV or chlorine). Out of 19 post-preliminary samples, adenovirus by quantitative polymerase chain reaction (qPCR) was detected in all 19, enterovirus by quantitative reverse transcription polymerase chain reaction (qRT-PCR) was detected in 15, and norovirus GI by qRT-PCR was detected in 11. Norovirus GII and Hepatitis A virus were not detected in any samples, and rotavirus was detected in one sample but could not be quantified. Although culturable viruses were found in 12 out of 19 post-preliminary samples, they were not detected in any post-secondary, post-MBR, post-ultraviolet, or post-chlorine samples. Median log removals for all organisms were higher for MBR secondary treatment (3.02 to >6.73) than for conventional secondary (1.53-4.19) treatment. Ultraviolet disinfection after MBR treatment provided little additional log removal of any organism except for somatic coliphage (>2.18), whereas ultraviolet or chlorine disinfection after conventional secondary treatment provided significant log removals (above the analytical variability) of all bacterial indicators (1.18-3.89) and somatic and F-specific coliphage (0.71 and >2.98). Median log removals of adenovirus across disinfection were low in both MBR and conventional secondary plants (no removal detected and 0.24), and few removals of individual samples were near or above the analytical variability of 1.2 log genomic copies per liter. Based on qualitative examinations of plots showing reductions of organisms throughout treatment processes, somatic coliphage may best represent the removal of viruses across secondary treatment in both MBR and conventional secondary plants. F-specific coliphage and Escherichia coli may best represent the removal of viruses across the disinfection process in MBR facilities, but none of the indicators represented the removal of viruses across disinfection in conventional secondary plants.
Crebelli, R; Conti, L; Monarca, S; Feretti, D; Zerbini, I; Zani, C; Veschetti, E; Cutilli, D; Ottaviani, M
2005-03-01
Wastewater disinfection is routinely carried out to prevent the spread of human pathogens present in wastewater effluents. To this aim, chemical and physical treatments are applied to the effluents before their emission in water bodies. In this study, the influence of two widely used disinfectants, peracetic acid (PAA) and sodium hypochlorite (NaClO), on the formation of mutagenic by-products was investigated. Wastewater samples were collected before and after disinfection, in winter and in summer, at a pilot plant installed in a municipal wastewater-treatment plant. Samples were adsorbed using silica C18 cartridges and the concentrates were tested for mutagenicity in the Salmonella typhimurium reversion test with strains TA98 and TA100. Non-concentrated water samples were tested with two plant genotoxicity assays (the Allium cepa root anaphase aberration test and the Tradescantia/micronucleus test). Mutagenicity assays in bacteria and in Tradescantia showed borderline mutagenicity in some of the wastewater samples, independent of the disinfection procedure applied. Negative results were obtained in the A. cepa anaphase aberration test. These results indicate that, in the conditions applied, wastewater disinfection with PAA and NaClO does not lead to the formation of significant amounts of genotoxic by-products.
A pilot study of solar water disinfection in the wilderness setting.
Tedeschi, Christopher M; Barsi, Christopher; Peterson, Shane E; Carey, Kevin M
2014-09-01
Solar disinfection of water has been shown to be an effective treatment method in the developing world, but not specifically in a wilderness or survival setting. The current study sought to evaluate the technique using materials typically available in a wilderness or backcountry environment. Untreated surface water from a stream in rural Costa Rica was disinfected using the solar disinfection (SODIS) method, using both standard containers as well as containers and materials more readily available to a wilderness traveler. Posttreatment samples using polyethylene terephthalate (PET) bottles, as well as Nalgene and Platypus water containers, showed similarly decreased levels of Escherichia coli and total coliforms. The SODIS technique may be applicable in the wilderness setting using tools commonly available in the backcountry. In this limited trial, specific types of containers common in wilderness settings demonstrated similar performance to the standard containers. With further study, solar disinfection in appropriate conditions may be included as a viable treatment option for wilderness water disinfection. Copyright © 2014 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.
Mika, K B; Imamura, G; Chang, C; Conway, V; Fernandez, G; Griffith, J F; Kampalath, R A; Lee, C M; Lin, C-C; Moreno, R; Thompson, S; Whitman, R L; Jay, J A
2009-07-01
Factors affecting faecal indicator bacteria (FIB) and pathogen survival/persistence in sand remain largely unstudied. This work elucidates how biological and physical factors affect die-off in beach sand following sewage spills. Solar disinfection with mechanical mixing was pilot-tested as a disinfection procedure after a large sewage spill in Los Angeles. Effects of solar exposure, mechanical mixing, predation and/or competition, season, and moisture were tested at bench scale. First-order decay constants for Escherichia coli ranged between -0.23 and -1.02 per day, and for enterococci between -0.5 and -1.0 per day. Desiccation was a dominant factor for E. coli but not enterococci inactivation. Effects of season were investigated through a comparison of experimental results from winter, spring, and fall. Moisture was the dominant factor controlling E. coli inactivation kinetics. Initial microbial community and sand temperature were also important factors. Mechanical mixing, common in beach grooming, did not consistently reduce bacterial levels. Inactivation rates are mainly dependent on moisture and high sand temperature. Chlorination was an effective disinfection treatment in sand microcosms inoculated with raw influent.
Ye, Zhangying; Wang, Shuo; Gao, Weishan; Li, Haijun; Pei, Luowei; Shen, Mingwei; Zhu, Songming
2017-01-01
A new physico-chemical process for TAN (total ammonia nitrogen) removal and disinfection is introduced in saline recirculating aquaculture system (RAS), in which the biofilter is replaced with an integrated electrolysis cell and an activated carbon filter. The electrolysis cell which is based on micro current electrolysis combined with UV-light was self-designed. After the fundamental research, a small pilot scale RAS was operated for 30 days to verify the technical feasibility. The system was stocked by 42 GIFT tilapia (Oreochromis niloticus) fish with the rearing density of 13 kg/m3. During the experiments, the TAN concentration remained below 1.0 mg/L. The nitrite concentration was lower than 0.2 mg/L and the nitrate concentration had increased continuously to 12.79 mg/L at the end. Furthermore, the concentration of residual chlorine in culture ponds remained below 0.3 mg/L, ORP maintained slight fluctuations in the range of 190~240 mV, and pH of the water showed the downtrend. Tilapia weight increased constantly to 339.3 ± 10 g. For disinfection, the active chlorine generated by electrochemical treatment caused Escherichia coli inactivation. Enzyme activity assay indicated that the activity of glutamate dehydrogenase, carbonic anhydrase and glutamic pyruvic transaminase increased within the normal range. The preliminary feasibility was verified by using this physico-chemical technology in the RAS. PMID:28345583
NASA Astrophysics Data System (ADS)
Ye, Zhangying; Wang, Shuo; Gao, Weishan; Li, Haijun; Pei, Luowei; Shen, Mingwei; Zhu, Songming
2017-03-01
A new physico-chemical process for TAN (total ammonia nitrogen) removal and disinfection is introduced in saline recirculating aquaculture system (RAS), in which the biofilter is replaced with an integrated electrolysis cell and an activated carbon filter. The electrolysis cell which is based on micro current electrolysis combined with UV-light was self-designed. After the fundamental research, a small pilot scale RAS was operated for 30 days to verify the technical feasibility. The system was stocked by 42 GIFT tilapia (Oreochromis niloticus) fish with the rearing density of 13 kg/m3. During the experiments, the TAN concentration remained below 1.0 mg/L. The nitrite concentration was lower than 0.2 mg/L and the nitrate concentration had increased continuously to 12.79 mg/L at the end. Furthermore, the concentration of residual chlorine in culture ponds remained below 0.3 mg/L, ORP maintained slight fluctuations in the range of 190~240 mV, and pH of the water showed the downtrend. Tilapia weight increased constantly to 339.3 ± 10 g. For disinfection, the active chlorine generated by electrochemical treatment caused Escherichia coli inactivation. Enzyme activity assay indicated that the activity of glutamate dehydrogenase, carbonic anhydrase and glutamic pyruvic transaminase increased within the normal range. The preliminary feasibility was verified by using this physico-chemical technology in the RAS.
Nie, Xuebiao; Liu, Wenjun; Zhang, Liping; Liu, Qing
2017-06-01
The genotoxicity of drinking water treated with 6 disinfection methods and the effects of disinfection conditions were investigated using the umu-test. The pretreatment procedure of samples for the umu-test was optimized for drinking water analysis. The results of the umu-test were in good correlation with those of the Ames-test. The genotoxicity and production of haloacetic acids (HAAs) were the highest for chlorinated samples. UV+chloramination is the safest disinfection method from the aspects of genotoxicity, HAA production and inactivation effects. For chloramination, the effects of the mass ratio of Cl 2 to N of chloramine on genotoxicity were also studied. The changes of genotoxicity were different from those of HAA production, which implied that HAA production cannot represent the genotoxic potential of water. The genotoxicity per chlorine decay of chlorination and chloramination had similar trends, indicating that the reaction of organic matters and chlorine made a great contribution to the genotoxicity. The results of this study are of engineering significance for optimizing the operation of waterworks. Copyright © 2016. Published by Elsevier B.V.
Uses of inorganic hypochlorite (bleach) in health-care facilities.
Rutala, W A; Weber, D J
1997-01-01
Hypochlorite has been used as a disinfectant for more than 100 years. It has many of the properties of an ideal disinfectant, including a broad antimicrobial activity, rapid bactericidal action, reasonable persistence in treated potable water, ease of use, solubility in water, relative stability, relative nontoxicity at use concentrations, no poisonous residuals, no color, no staining, and low cost. The active species is undissociated hypochlorous acid (HOCl). Hypochlorites are lethal to most microbes, although viruses and vegetative bacteria are more susceptible than endospore-forming bacteria, fungi, and protozoa. Activity is reduced by the presence of heavy metal ions, a biofilm, organic material, low temperature, low pH, or UV radiation. Clinical uses in health-care facilities include hyperchlorination of potable water to prevent Legionella colonization, chlorination of water distribution systems used in hemodialysis centers, cleaning of environmental surfaces, disinfection of laundry, local use to decontaminate blood spills, disinfection of equipment, decontamination of medical waste prior to disposal, and dental therapy. Despite the increasing availability of other disinfectants, hypochlorites continue to find wide use in hospitals. PMID:9336664
Fornwalt, Lori; Riddell, Brad
2014-01-01
It is widely acknowledged that the hospital environment is an important reservoir for many of the pathogenic microbes associated with health care-associated infections (HAIs). Environmental cleaning plays an important role in the prevention and containment of HAIs, in patient safety, and the overall experience of health care facilities. New technologies, such as pulsed xenon ultraviolet (PX-UV) light systems are an innovative development for enhanced cleaning and decontamination of hospital environments. A portable PX-UV disinfection device delivers pulsed UV light to destroy microbial pathogens and spores, and can be used in conjunction with manual environmental cleaning. In addition, this technology facilitates thorough disinfection of hospital rooms in 10-15 minutes. The current study was conducted to evaluate whether the introduction of the PX-UV device had a positive impact on patient satisfaction. Satisfaction was measured using the Hospital Consumer Assessment of Healthcare Providers and Systems (HCAHPS) survey. In 2011, prior to the introduction of the PX-UV system, patient HCAHPS scores for cleanliness averaged 75.75%. In the first full quarter after enhanced cleaning of the facility was introduced, this improved to 83%. Overall scores for the hospital rose from 76% (first quarter, 2011) to 87.6% (fourth quarter, 2012). As a result of this improvement, the hospital received 1% of at-risk reimbursement from the inpatient prospective payment system as well as additional funding. Cleanliness of the hospital environment is one of the questions included in the HCAHPS survey and one measure of patient satisfaction. After the introduction of the PX-UV system, the score for cleanliness and the overall rating of the hospital rose from below the fiftieth to the ninety-ninth percentile. This improvement in the patient experience was associated with financial benefits to the hospital.
Bernbom, N; Vogel, B F; Gram, L
2011-05-14
The bactericidal effect on food processing surfaces of ceiling-mounted UV-C light (wavelength 254 nm) was determined in a fish smoke house after the routine cleaning and disinfection procedure. The total aerobic counts were reduced during UV-C light exposure (48 h) and the number of Listeria monocytogenes positive samples went from 30 (of 68) before exposure to 8 (of 68). We therefore in a laboratory model determined the L. monocytogenes reduction kinetics by UV-C light with the purpose of evaluating the influence of food production environmental variables, such as presence of NaCl, organic material and the time L. monocytogenes was allowed to adhere to steel before exposure. L. monocytogenes grown and attached in tryptone soy broth (TSB) with glucose were rapidly killed (after 2 min) by UV-C light. However, bacteria grown and adhered in TSB with glucose and 5% NaCl were more resistant and numbers declined with 4-5 log units during exposure of 8-10 min. Bacteria grown in juice prepared from cold-smoked salmon were protected and numbers were reduced with 2-3 log when UV-C light was used immediately after attachment whereas numbers did not change at all if bacteria had been allowed to form a biofilm for 7 days before exposure. It is not known if this enhanced survival is due to physiological changes in the attached bacterial cells, a physical protection of the cells in the food matrix or a combination. In conclusion, we demonstrate that UV-C light is a useful extra bacteriocidal step and that it, as all disinfecting procedures, is hampered by the presence of organic material. Copyright © 2011 Elsevier B.V. All rights reserved.
Miklos, David B; Hartl, Rebecca; Michel, Philipp; Linden, Karl G; Drewes, Jörg E; Hübner, Uwe
2018-06-01
This study investigated the removal of 15 trace organic chemicals (TOrCs) occurring at ambient concentrations from municipal wastewater treatment plant effluent by advanced oxidation using UV/H 2 O 2 at pilot-scale. Pseudo first-order rate constants (k obs ) for photolytic as well as combined oxidative and photolytic degradation observed at pilot-scale were validated with results from a bench-scale collimated beam device. No significant difference was determined between pilot- and lab-scale performance. During continuous pilot-scale operation at constant UV fluence of 800 mJ/cm 2 and H 2 O 2 dosage of 10 mg/L, the removal of various TOrCs was investigated. The average observed removal for photo-susceptible (k UV >10 -3 cm 2 /mJ; like diclofenac, iopromide and sulfamethoxazole), moderately photo-susceptible (10 -4
Zhang, Shuangyi; Gitungo, Stephen; Axe, Lisa; Dyksen, John E; Raczko, Robert F
2016-11-15
With widespread occurrence of pharmaceuticals and personal care products (PPCPs) in the water cycle, their presence in source water has led to the need to better understand their treatability and removal efficiency in treatment processes. Fifteen indicator compounds were identified to represent the large number of PPCPs reported worldwide. Criteria applied to determine the indicator compounds included PPCPs widely used, observed at great frequency in aqueous systems, resistant to treatment, persistent in the environment, and representative of classes of organics. Through a pilot plant investigation to understand the optimal combination of unit process for treating PPCPs, 12 treatment trains with their additive and synergistic contributions were investigated; processes included dissolved air flotation (DAF), pre- and intermediate-ozonation with and without H 2 O 2 , intermediate chlorination, dual media filtration, granular activated carbon (GAC), and UV/H 2 O 2 . Treatment trains that achieved the greatest removals involved 1. DAF followed by intermediate ozonation, dual media filtration, and virgin GAC; 2. pre-ozonation followed by DAF, dual media filtration, and virgin GAC; and, 3. DAF (with either pre- or intermediate oxidation) followed by dual media filtration and UV/H 2 O 2 . Results revealed significant removal efficiencies for virgin GAC (preceded by DAF and intermediate ozonation) and UV/H 2 O 2 with an intensity of 700 mJ/cm 2 , where more than 12 of the compounds were removed by greater than 90%. Reduced PPCP removals were observed with virgin GAC preceded by pre-ozonation and DAF. Intermediate ozonation was more effective than using pre-ozonation, demonstrating the importance of this process targeting PPCPs after treatment of natural organic matter. Removal efficiencies of indicator compounds through ozonation were found to be a function of the O 3 rate constants (k O3 ). For compounds with low O 3 rate constants (k O3 < 10 M -1 s -1 ), H 2 O 2 addition in the O 3 reactor was required. Of the 15 indicator compounds, tri(2-chloroethyl) phosphate (TCEP) and cotinine were observed to be the most recalcitrant. Although UV/H 2 O 2 with elevated intensity (700 mJ/cm 2 ) was effective for PPCP removals, energy requirements far exceed intensities applied for disinfection. Copyright © 2016 Elsevier Ltd. All rights reserved.
Chen, Huei-Wen; Chen, Chia-Yang; Wang, Gen-Shuh
2011-10-01
The presence of various organic contaminants in water sources is of concern due to their direct threats to human health and potential to react with disinfectants to form carcinogenic byproducts including trihalomethanes, haloacetic acids and nitrosamines in finished water. This study applied both medium-pressure and low-pressure ultraviolet light coupled with hydrogen peroxide (UV/H2O2) to evaluate its efficacy for degradation of selected nitrogenous organic compounds and corresponding disinfection byproduct (DBP) formation. Six organic compounds were chosen as target precursors based on their nitrogen contents and molecular structures. The results showed that higher oxidation capacity resulted in better reduction of organic matters and DBP formation potentials (DBPFPs). However, insufficient contact time and oxidant doses could lead to a rise of DBPFPs in the early stages of UV/H2O2 reactions. A greater percentage removal was achieved for organic carbon than organic nitrogen after UV/H2O2 treatment, especially for compounds with complicated structure such as diltiazem. During the UV/H2O2 treatment, the intermediate products include tertiary amine, dimethyl amine (DMA) or DMA-like structures, which are N-nitrosodimethylamine (NDMA) precursors after chlorination or chloramination. Furthermore, it was observed that using dissolved organic nitrogen and DMA to predict NDMAFP could lead to biased conclusions because of the complex nature of nitrogenous matters in aqueous environments. Copyright © 2011 Elsevier Ltd. All rights reserved.
Life Cycle Environmental Impacts of Disinfection Technologies Used in Small Drinking Water Systems.
Jones, Christopher H; Shilling, Elizabeth G; Linden, Karl G; Cook, Sherri M
2018-03-06
Small drinking water systems serve a fifth of the U.S. population and rely heavily on disinfection. While chlorine disinfection is common, there is interest in minimizing chemical addition, especially due to carcinogenic disinfection byproducts and chlorine-resistant pathogens, by using ultraviolet technologies; however, the relative, broader environmental impacts of these technologies are not well established, especially in the context of small (<10 000 people) water systems. The objective of this study was to identify environmental trade-offs between chlorine and ultraviolet disinfection via comparative life cycle assessment. The functional unit was the production of 1 m 3 of drinking water to U.S. Treatment included cartridge filtration followed by either chlorine disinfection or ultraviolet disinfection with chlorine residual addition. Environmental performance was evaluated for various chlorine contact zone materials (plastic, concrete, steel), ultraviolet validation factors (1.2 to 4.4), and electricity sources (renewable; U.S. average, high, and low impact grids). Performance was also evaluated when filtration and chlorine residual were not required. From a life cycle assessment perspective, replacing chlorine with UV was preferred only in a limited number of cases (i.e., high pumping pressure but filtration is not required). In all others, chlorine was environmentally preferred, although some contact zone materials and energy sources had an impact on the comparison. Utilities can use these data to inform their disinfection technology selection and operation to minimize environmental and human health impacts.
S, Sreeja; K, Vidya Shetty
2016-09-01
The studies on photocatalytic disinfection of water contaminated with Escherichia coli using Ag core and TiO2 shell (Ag@TiO2) nanoparticles under UV irradiation showed that these nanoparticles are very efficient in water disinfection both in their free and immobilised form. Complete disinfection of 40 × 10(8) CFU/mL could be achieved in 60 min with 0.4 g/L catalyst loading and in 35 min with 1 g/L catalyst loading. Ag@TiO2 nanoparticles were found to be superior to TiO2 nanoparticles in photocatalytic disinfection of water. Kinetics of disinfection followed Chick's law, and the pseudo-first-order rate constant was 0.0168 min(-1) for a catalyst loading of 0.1 g/L. Disinfection of water and degradation of endotoxins (harmful disinfection residual) occurred simultaneously during photocatalysis thereby making the treated water safe for use. Endotoxin degradation showed a shifting order of kinetics. The rate of photocatalysis with nanoparticles immobilised in cellulose acetate film was marginally lower as compared to that of free nanoparticles. Negligible Ag ion leakage and re-growth of cells post-photo-catalytic treatment of water confirmed that complete disintegration of E. coli occurred during photocatalysis making the treated water safe for use. Therefore, Ag@TiO2 nanoparticles have a potential for large-scale application in drinking water treatment plants and household purification units.
Van Haute, S; López-Gálvez, F; Gómez-López, V M; Eriksson, Markus; Devlieghere, F; Allende, Ana; Sampers, I
2015-09-02
A methodology to i) assess the feasibility of water disinfection in fresh-cut leafy greens wash water and ii) to compare the disinfectant efficiency of water disinfectants was defined and applied for a combination of peracetic acid (PAA) and lactic acid (LA) and comparison with free chlorine was made. Standardized process water, a watery suspension of iceberg lettuce, was used for the experiments. First, the combination of PAA+LA was evaluated for water recycling. In this case disinfectant was added to standardized process water inoculated with Escherichia coli (E. coli) O157 (6logCFU/mL). Regression models were constructed based on the batch inactivation data and validated in industrial process water obtained from fresh-cut leafy green processing plants. The UV254(F) was the best indicator for PAA decay and as such for the E. coli O157 inactivation with PAA+LA. The disinfection efficiency of PAA+LA increased with decreasing pH. Furthermore, PAA+LA efficacy was assessed as a process water disinfectant to be used within the washing tank, using a dynamic washing process with continuous influx of E. coli O157 and organic matter in the washing tank. The process water contamination in the dynamic process was adequately estimated by the developed model that assumed that knowledge of the disinfectant residual was sufficient to estimate the microbial contamination, regardless the physicochemical load. Based on the obtained results, PAA+LA seems to be better suited than chlorine for disinfecting process wash water with a high organic load but a higher disinfectant residual is necessary due to the slower E. coli O157 inactivation kinetics when compared to chlorine. Copyright © 2015 Elsevier B.V. All rights reserved.
Zyara, Alyaa M; Torvinen, Eila; Veijalainen, Anna-Maria; Heinonen-Tanski, Helvi
2016-08-01
Chlorine disinfection is a globally used method to ensure the safety of drinking water. However, it has not always been successful against viruses and, therefore, it is important to find new methods to disinfect water. Seventeen different coliphages were isolated from the treated municipal wastewater. These coliphages and MS2 were treated with different dosages of chlorine in drinking water, and a combined chlorine/ultraviolet irradiation treatment for the chlorine-resistant coliphages. Chlorine disinfection with 0.3-0.5 mg/L total chlorine (free Cl-dosage 0.12-0.21 mg/L) for 10 min achieved 2.5-5.7 Log10-reductions for 11 sensitive coliphages. The six most resistant coliphages showed no reduction with these chlorine concentrations. MS2 was intermediate in chlorine resistance, and thus it is not a good indicator for viruses in chlorine disinfection. In the combined treatment total chlorine of 0.05-0.25 mg/L (free Cl-dosage 0.02-0.08 mg/L) and ultraviolet irradiation (14-22 mWs/cm(2)) were more effective than chlorine alone, and 3-5 Log10-reductions were achieved for the chlorine-resistant strains. The chlorination efficiency could be increased by higher dosages and longer contact times, but this could increase the formation of disinfection by-products. Therefore, the combination treatment is a recommended disinfection method.
Evaluation of a UV/Ozone Treatment Process for Removal of MTBE in Groundwater Supplies in New Mexico
EPA’s Office of Research and Development is funding pilot-scale studies on MTBE contaminated groundwater using UV/ozone treatment technology (254 nm UV, 5.8 mg/L ozone). The pilot-scale treatment system consists of a GW well pump, a feed tank, a pretreatment system (water soften...
Evaluation of a UV/Ozone Treatment Process for Removal of MTBE in Groundwater Supplies in New Mexico
EPA’s Office of Research and Development is funding pilot-scale studies on MTBE contaminated groundwater using UV/ozone treatment technology (254 nm UV, 5.8 mg/L ozone). The pilot-scale treatment system consists of a GW well pump, a feed tank, a pretreatment system (water softene...
Hügler, Michael; Böckle, Karin; Eberhagen, Ingrid; Thelen, Karin; Beimfohr, Claudia; Hambsch, Beate
2011-01-01
Monitoring of microbiological contaminants in water supplies requires fast and sensitive methods for the specific detection of indicator organisms or pathogens. We developed a protocol for the simultaneous detection of E. coli and coliform bacteria based on the Fluorescence in situ Hybridization (FISH) technology. This protocol consists of two approaches. The first allows the direct detection of single E. coli and coliform bacterial cells on the filter membranes. The second approach includes incubation of the filter membranes on a nutrient agar plate and subsequent detection of the grown micro-colonies. Both approaches were validated using drinking water samples spiked with pure cultures and naturally contaminated water samples. The effects of heat, chlorine and UV disinfection were also investigated. The micro-colony approach yielded very good results for all samples and conditions tested, and thus can be thoroughly recommended for usage as an alternative method to detect E. coli and coliform bacteria in water samples. However, during this study, some limitations became visible for the single cell approach. The method cannot be applied for water samples which have been disinfected by UV irradiation. In addition, our results indicated that green fluorescent dyes are not suitable to be used with chlorine disinfected samples.
Products identified at an alternative disinfection pilot plant.
Lykins, B W; Koffskey, W
1986-01-01
Many drinking water utilities have recently changed or are seriously considering changing their disinfection practice from chlorine to some alternative treatment process. However, most of these utilities are changing their disinfectants without evaluating chemical impacts. Therefore, a research cooperative agreement was developed with Jefferson Parish, LA, to evaluate four parallel streams treated with four different disinfectants (chlorine, monochloramine, chlorine dioxide, and ozone.) These streams, along with a fifth parallel stream, which was not treated with a disinfectant (control), were passed through both sand and granular activated carbon (GAC). Ozonation reduced the total organic carbon (TOC) and total organic halide (TOX) concentration by 0.3 mg/L and 10 micrograms/L, respectively. The average concentration of TOC for the other disinfectants was comparable to that associated with the nondisinfected stream (3.3 mg/L). The average instantaneous TOX concentration for chlorine dioxide, chloramine, and chlorine disinfection after 30 min contact time increased by 60, 92, and 238 micrograms/L, respectively, from a nondisinfected concentration of 25 micrograms/L. The volatile organics most affected by disinfection (chlorination) were the trihalomethanes. No significant change in concentration was noted after disinfection for the other volatile organics evaluated, such as 1,2-dichlorethane, dichloromethane, trichloroethylene, 1,1,2-trichloroethane, and carbon tetrachloride. Ozonation produced an average concentration reduction of 11 to 84% for most of the nonvolatiles evaluated. Conversely, a concentration increase of 43 to 100% was noted, after chlorination, for some of the nonvolatile organics. PMID:3816717
Products identified at an alternative disinfection pilot plant
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lykins, B.W. Jr.; Koffskey, W.
1986-11-01
Many drinking water utilities have recently changed or are seriously considering changing their disinfection practice from chlorine to some alternative treatment process. However, most of these utilities are changing their disinfectants without evaluating chemical impacts. Therefore, a research cooperative agreement was developed with Jefferson Parish, LA, to evaluate four parallel streams treated with four different disinfectants (chlorine, monochloramine, chlorine dioxide, and ozone.) These streams, along with a fifth parallel stream, which was not treated with a disinfectant (control), were passed through both sand and granular activated carbon (GAC). Ozonation reduced the total organic carbon (TOC) and total organic halide (TOX)more » concentration by 0.3 mg/L and 10 micrograms/L, respectively. The average concentration of TOC for the other disinfectants was comparable to that associated with the nondisinfected stream (3.3 mg/L). The average instantaneous TOX concentration for chlorine dioxide, chloramine, and chlorine disinfection after 30 min contact time increased by 60, 92, and 238 micrograms/L, respectively, from a nondisinfected concentration of 25 micrograms/L. The volatile organics most affected by disinfection (chlorination) were the trihalomethanes. No significant change in concentration was noted after disinfection for the other volatile organics evaluated, such as 1,2-dichlorethane, dichloromethane, trichloroethylene, 1,1,2-trichloroethane, and carbon tetrachloride. Ozonation produced an average concentration reduction of 11 to 84% for most of the nonvolatiles evaluated. Conversely, a concentration increase of 43 to 100% was noted, after chlorination, for some of the nonvolatile organics.« less
OVERVIEW: DISINFECTION OF HELICOBACTER PYLORI AND AEROMONAS SPECIES
Helicobacter pylori and Aeromonas hydrophila are contaminants listed on the USEPA's 1998 Contaminant Candidate List (CCL).The sensitivity of H. pylori to chlorine and of Aeromonas spp. to inactivation by free chlorine, chloramine and ultraviolet (UV) was examined. Selective and...
ULTRAVIOLET (UV) DISINFECTION SYSTEMS FOR SECONDARY WASTEWATER EFFLUENT AND WATER REUSE
The U.S. Environmental Protection Agency (EPA) Environmental Technology Verification (ETV) program evaluates the performance of innovative air, water, pollution prevention and monitoring technologies that have the potential to improve human health and the environment. This techn...
Vughs, D; Baken, K A; Kolkman, A; Martijn, A J; de Voogt, P
2018-02-01
Advanced oxidation processes are important barriers for organic micropollutants in (drinking) water treatment. It is however known that medium pressure UV/H 2 O 2 treatment may lead to mutagenicity in the Ames test, which is no longer present after granulated activated carbon (GAC) filtration. Many nitrogen-containing disinfection by-products (N-DBPs) result from the reaction of photolysis products of nitrate with (photolysis products of) natural organic material (NOM) during medium pressure UV treatment of water. Identification of the N-DBPs and the application of effect-directed analysis to combine chemical screening results with biological activity would provide more insight into the relation of specific N-DBPs with the observed mutagenicity and was the subject of this study. To this end, fractions of medium pressure UV-treated and untreated water extracts were prepared using preparative HPLC and tested using the Ames fluctuation test. In addition, high-resolution mass spectrometry was performed on all fractions to assess the presence of N-DBPs. Based on toxicity data and read across analysis, we could identify five N-DBPs that are potentially genotoxic and were present in relatively high concentrations in the fractions in which mutagenicity was observed. The results of this study offer opportunities to further evaluate the identity and potential health concern of N-DBPs formed during advanced oxidation UV drinking water treatment.
Muraca, P; Stout, J E; Yu, V L
1987-01-01
Nosocomial Legionnaires disease can be acquired by exposure to the organism from the hospital water distribution system. As a result, many hospitals have instituted eradication procedures, including hypercholorination and thermal eradication. We compared the efficacy of ozonation, UV light, hyperchlorination, and heat eradication using a model plumbing system constructed of copper piping, brass spigots, Plexiglas reservoir, electric hot water tank, and a pump. Legionella pneumophila was added to the system at 10(7) CFU/ml. Each method was tested under three conditions; (i) nonturbid water at 25 degrees C, (ii) turbid water at 25 degrees C, and (iii) nonturbid water at 43 degrees C. UV light and heat killed L. pneumophila most rapidly and required minimal maintenance. Both UV light and heat (60 degrees C) produced a 5 log kill in less than 1 h. In contrast, both chlorine and ozone required 5 h of exposure to produce a 5 log decrease. Neither turbidity nor the higher temperature of 43 degrees C impaired the efficacy of any of the disinfectant methods. Surprisingly, higher temperature enhanced the disinfecting efficacy of chlorine. However, higher temperature accelerated the decomposition of the chlorine residual such that an additional 120% volume of chlorine was required. All four methods proved efficacious in eradicating L. pneumophila from a model plumbing system. Images PMID:3566272
Lambertini, Elisabetta; Borchardt, Mark A; Kieke, Burney A; Spencer, Susan K; Loge, Frank J
2012-09-04
Acute gastrointestinal illness (AGI) resulting from pathogens directly entering the piping of drinking water distribution systems is insufficiently understood. Here, we estimate AGI incidence from virus intrusions into the distribution systems of 14 nondisinfecting, groundwater-source, community water systems. Water samples for virus quantification were collected monthly at wells and households during four 12-week periods in 2006-2007. Ultraviolet (UV) disinfection was installed on the communities' wellheads during one study year; UV was absent the other year. UV was intended to eliminate virus contributions from the wells and without residual disinfectant present in these systems, any increase in virus concentration downstream at household taps represented virus contributions from the distribution system (Approach 1). During no-UV periods, distribution system viruses were estimated by the difference between well water and household tap virus concentrations (Approach 2). For both approaches, a Monte Carlo risk assessment framework was used to estimate AGI risk from distribution systems using study-specific exposure-response relationships. Depending on the exposure-response relationship selected, AGI risk from the distribution systems was 0.0180-0.0661 and 0.001-0.1047 episodes/person-year estimated by Approaches 1 and 2, respectively. These values represented 0.1-4.9% of AGI risk from all exposure routes, and 1.6-67.8% of risk related to drinking water exposure. Virus intrusions into nondisinfected drinking water distribution systems can contribute to sporadic AGI.
Mofidi, Alexander A; Meyer, Ernest A; Wallis, Peter M; Chou, Connie I; Meyer, Barbara P; Ramalingam, Shivaji; Coffey, Bradley M
2002-04-01
This study measured the effect of germicidal ultraviolet (UV) light on Giardia lamblia and Giardia muris cysts, as determined by their infectivity in Mongolian gerbils and CD-1 mice, respectively. Reduction of cyst infectivity due to UV exposure was quantified by applying most probable number techniques. Controlled bench-scale, collimated-beam tests exposed cysts suspended in filtered natural water to light from a low-pressure UV lamp. Both G. lamblia and G. muris cysts showed similar sensitivity to UV light. At 3 mJ/cm2, a dose 10-fold lower than what large-scale UV reactors may be designed to provide, > 2-log10 (99 percent) inactivation was observed. These results, combined with previously published data showing other protozoa and bacteria have similar, high sensitivity to UV light, establish that UV disinfection of drinking water is controlled by viruses which may require over 10-fold more UV dose for the same level of control.
Disinfection of bacterial biofilms in pilot-scale cooling tower systems
Liu, Yang; Zhang, Wei; Sileika, Tadas; Warta, Richard; Cianciotto, Nicholas P.; Packman, Aaron I.
2015-01-01
The impact of continuous chlorination and periodic glutaraldehyde treatment on planktonic and biofilm microbial communities was evaluated in pilot-scale cooling towers operated continuously for 3 months. The system was operated at a flow rate of 10,080 l day−1. Experiments were performed with a well-defined microbial consortium containing three heterotrophic bacteria: Pseudomonas aeruginosa, Klebsiella pneumoniae and Flavobacterium sp. The persistence of each species was monitored in the recirculating cooling water loop and in biofilms on steel and PVC coupons in the cooling tower basin. The observed bacterial colonization in cooling towers did not follow trends in growth rates observed under batch conditions and, instead, reflected differences in the ability of each organism to remain attached and form biofilms under the high-through flow conditions in cooling towers. Flavobacterium was the dominant organism in the community, while P. aeruginosa and K. pneumoniae did not attach well to either PVC or steel coupons in cooling towers and were not able to persist in biofilms. As a result, the much greater ability of Flavobacterium to adhere to surfaces protected it from disinfection, whereas P. aeruginosa and K. pneumoniae were subject to rapid disinfection in the planktonic state. PMID:21547755
Mika, K.B.; Imamura, G.; Chang, C.; Conway, V.; Fernandez, G.; Griffith, J.F.; Kampalath, R.A.; Lee, C.M.; Lin, C.-C.; Moreno, R.; Thompson, S.; Whitman, R.L.; Jay, J.A.
2009-01-01
Aim: Factors affecting faecal indicator bacteria (FIB) and pathogen survival/persistence in sand remain largely unstudied. This work elucidates how biological and physical factors affect die-off in beach sand following sewage spills. Methods and Results: Solar disinfection with mechanical mixing was pilot-tested as a disinfection procedure after a large sewage spill in Los Angeles. Effects of solar exposure, mechanical mixing, predation and/or competition, season, and moisture were tested at bench scale. First-order decay constants for Escherichia coli ranged between -0??23 and -1??02 per day, and for enterococci between -0??5 and -1??0 per day. Desiccation was a dominant factor for E. coli but not enterococci inactivation. Effects of season were investigated through a comparison of experimental results from winter, spring, and fall. Conclusions: Moisture was the dominant factor controlling E. coli inactivation kinetics. Initial microbial community and sand temperature were also important factors. Mechanical mixing, common in beach grooming, did not consistently reduce bacterial levels. Significance and Impact of the Study: Inactivation rates are mainly dependent on moisture and high sand temperature. Chlorination was an effective disinfection treatment in sand microcosms inoculated with raw influent. ?? 2009 The Society for Applied Microbiology.
Disinfection of bacterial biofilms in pilot-scale cooling tower systems.
Liu, Yang; Zhang, Wei; Sileika, Tadas; Warta, Richard; Cianciotto, Nicholas P; Packman, Aaron I
2011-04-01
The impact of continuous chlorination and periodic glutaraldehyde treatment on planktonic and biofilm microbial communities was evaluated in pilot-scale cooling towers operated continuously for 3 months. The system was operated at a flow rate of 10,080 l day(-1). Experiments were performed with a well-defined microbial consortium containing three heterotrophic bacteria: Pseudomonas aeruginosa, Klebsiella pneumoniae and Flavobacterium sp. The persistence of each species was monitored in the recirculating cooling water loop and in biofilms on steel and PVC coupons in the cooling tower basin. The observed bacterial colonization in cooling towers did not follow trends in growth rates observed under batch conditions and, instead, reflected differences in the ability of each organism to remain attached and form biofilms under the high-through flow conditions in cooling towers. Flavobacterium was the dominant organism in the community, while P. aeruginosa and K. pneumoniae did not attach well to either PVC or steel coupons in cooling towers and were not able to persist in biofilms. As a result, the much greater ability of Flavobacterium to adhere to surfaces protected it from disinfection, whereas P. aeruginosa and K. pneumoniae were subject to rapid disinfection in the planktonic state.
EVALUATING A COMPOSITE CARTRIDGE FOR SMALL SYSTEM DRINKING WATER TREATMENT
A multi-layer, cartridge-based system that combines physical filtration with carbon adsorption and ultraviolet (UV) light disinfection has been developed to perform as a water treatment security device to protect homes against accidental or intentional contaminant events. A seri...
USDA research enables total quat release from cotton nonwoven disinfecting wipes
USDA-ARS?s Scientific Manuscript database
The adsorption of alkyl-dimethyl-benzyl-ammonium chloride (ADBAC), a cationic surfactant commonly employed as an antimicrobial agent, on various cotton, cotton-blend, and synthetic nonwoven fabrics was investigated at varying surfactant concentrations using UV-Vis absorption spectroscopy. Modifying ...
As the use of alternative drinking water treatment increases, it is important to understand potential public health•implications associated with these processes. The objective of this study was to evaluate the formation of disinfection byproducts (DBPs) and cytotoxicity of ...
Powerful colloidal silver nanoparticles for the prevention of gastrointestinal bacterial infections
NASA Astrophysics Data System (ADS)
Le, Anh-Tuan; Tam Le, Thi; Quy Nguyen, Van; Hoang Tran, Huy; Dang, Duc Anh; Tran, Quang Huy; Vu, Dinh Lam
2012-12-01
In this work we have demonstrated a powerful disinfectant ability of colloidal silver nanoparticles (NPs) for the prevention of gastrointestinal bacterial infections. The silver NPs colloid was synthesized by a UV-enhanced chemical precipitation. Two gastrointestinal bacterial strains of Escherichia coli (ATCC 43888-O157:k-:H7) and Vibrio cholerae (O1) were used to verify the antibacterial activity of the as-prepared silver NPs colloid by means of surface disinfection assay in agar plates and turbidity assay in liquid media. Transmission electron microscopy was also employed to analyze the ultrastructural changes of bacterial cells caused by silver NPs. Noticeably, our silver NPs colloid displayed a highly effective bactericidal effect against two tested gastrointestinal bacterial strains at a silver concentration as low as ˜3 mg l-1. More importantly, the silver NPs colloid showed an enhancement of antibacterial activity and long-lasting disinfectant effect as compared to conventional chloramin B (5%) disinfection agent. These advantages of the as-prepared colloidal silver NPs make them very promising for environmental treatments contaminated with gastrointestinal bacteria and other infectious pathogens. Moreover, the powerful disinfectant activity of silver-containing materials can also help in controlling and preventing further outbreak of diseases.
Ley, Benjamin; Silverman, Edward; Peery, Kara; Dominguez, Delfina
2016-01-01
Nosocomial infections are a concern of growing interest in veterinary medicine. Clipper blades have been confirmed as fomites for numerous potential pathogens and, as such, may be associated with wound and surgical site infections. The goal of this study was to evaluate the disinfectant capabilities of several commonly used clipper blade cleaning products. Seventy sterile clipper blades were inoculated with strains of Pseudomonas aeruginosa , Escherichia coli , and Staphylococcus aureus . Blades were then subjected to one of seven treatment groups for disinfecting. Quantitative cultures of remaining bacteria were performed. All blades in the control group showed large amounts of bacterial recovery. Culture results showed no recovery in blades soaked in alcohol or chlorhexidine or those sprayed with an ethanol/o-phenylphenol product, while moderate recovery was seen with all other treatments. These results show that persistent contamination of clipper blades can occur with the use of several commonly used disinfectant products. Further research is necessary to evaluate fungicidal capabilities as well as the effect of disinfection on clipper blade maintenance.
Frequency of use controls chemical leaching from drinking-water containers subject to disinfection.
Andra, Syam S; Makris, Konstantinos C; Shine, James P
2011-12-15
Microbial-, and chemical-based burden of disease associated with lack of access to safe water continues to primarily impact developing countries. Cost-effective health risk-mitigating measures, such as of solar disinfection applied to microbial-contaminated water stored in plastic bottles have been increasingly tested in developing countries adversely impacted by epidemic water-borne diseases. Public health concerns associated with chemical leaching from water packaging materials led us to investigate the magnitude and variability of antimony (Sb) and bromine (Br) leaching from reused plastic containers (polyethylene terephthalate, PET; and polycarbonate, PC) subject to UV and/or temperature-driven disinfection. The overall objective of this study was to determine the main and interactive effects of temperature, UV exposure duration, and frequency of bottle reuse on the extent of leaching of Sb and Br from plastic bottles into water. Regardless of UV exposure duration, frequency of reuse (up to 27 times) was the major factor that linearly increased Sb leaching from PET bottles at all temperatures tested (13-47 °C). Leached Sb concentrations (∼360 ng L(-1)) from the highly reused (27 times) PET bottles (minimal Sb leaching from PC bottles, <15 ng L(-1)) did not pose a serious risk to human health according to current daily Sb acceptable intake estimates. Leached Br concentrations from both PET and PC containers (up to ∼15 μg L(-1)) did not pose a consumer health risk either, however, no acceptable daily dose estimates exist for oral ingestion of organo-brominated, or other plasticizers/additives compounds if they were to be found in bottled water at much lower concentrations. Additional research on potential leaching of organic chemicals from water packaging materials is deemed necessary under relevant environmental conditions. Copyright © 2011 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Gilmore, A. M.
2015-12-01
This study describes a method based on simultaneous absorbance and fluorescence excitation-emission mapping for rapidly and accurately monitoring dissolved organic carbon concentration and disinfection by-product formation potential for surface water sourced drinking water treatment. The method enables real-time monitoring of the Dissolved Organic Carbon (DOC), absorbance at 254 nm (UVA), the Specific UV Absorbance (SUVA) as well as the Simulated Distribution System Trihalomethane (THM) Formation Potential (SDS-THMFP) for the source and treated water among other component parameters. The method primarily involves Parallel Factor Analysis (PARAFAC) decomposition of the high and lower molecular weight humic and fulvic organic component concentrations. The DOC calibration method involves calculating a single slope factor (with the intercept fixed at 0 mg/l) by linear regression for the UVA divided by the ratio of the high and low molecular weight component concentrations. This method thus corrects for the changes in the molecular weight component composition as a function of the source water composition and coagulation treatment effects. The SDS-THMFP calibration involves a multiple linear regression of the DOC, organic component ratio, chlorine residual, pH and alkalinity. Both the DOC and SDS-THMFP correlations over a period of 18 months exhibited adjusted correlation coefficients with r2 > 0.969. The parameters can be reported as a function of compliance rules associated with required % removals of DOC (as a function of alkalinity) and predicted maximum contaminant levels (MCL) of THMs. The single instrument method, which is compatible with continuous flow monitoring or grab sampling, provides a rapid (2-3 minute) and precise indicator of drinking water disinfectant treatability without the need for separate UV photometric and DOC meter measurements or independent THM determinations.
Thomas, Simon F; Rooks, Paul; Rudin, Fabian; Atkinson, Sov; Goddard, Paul; Bransgrove, Rachel M; Mason, Paul T; Allen, Michael J
2014-01-01
We show in this study that the combination of a swirl flow reactor and an antimicrobial agent (in this case copper alginate beads) is a promising technique for the remediation of contaminated water in waste streams recalcitrant to UV-C treatment. This is demonstrated by comparing the viability of both common and UV-C resistant organisms in operating conditions where UV-C proves ineffective - notably high levels of solids and compounds which deflect UV-C. The swirl flow reactor is easy to construct from commonly available plumbing parts and may prove a versatile and powerful tool in waste water treatment in developing countries.
Fang, Shiyue; Guan, Yousheng; Blatchley, Ernest R; Shen, Chengyue; Bergstrom, Donald E
2008-03-01
( E)-5-[2-(Methoxycarbonyl)ethenyl]cytidine was biotinylated through a diisopropylsilylacetal linkage and attached to the surface of hydrophilic streptavidin-coated microspheres through the high-affinity noncovalent interaction between biotin and streptavidin. The functionalized microspheres form a stable suspension in water. Upon UV irradiation, the nonfluorescent ( E)-5-[2-(methoxycarbonyl)ethenyl]cytidine on the microspheres undergoes photocyclization to produce highly fluorescent 3-beta-D-ribofuranosyl-2,7-dioxopyrido[2,3-d]pyrimidine. The fluorescence intensity of the microspheres can be correlated to the particle-specific UV doses applied at different suspension concentrations. The microspheres allow one to measure the UV dose (fluence) distribution in high-throughput water disinfection systems.
Chandrappa, Mahesh Martur; Meharwade, Prasanna Mahadevasa; Srinivasan, Raghu; Bhandary, Shreetha; Nasreen, Farhat
2016-01-01
The objective of this study was to evaluate the effectiveness of 5.25% sodium hypochlorite (NaOCl), 2% chlorhexidine (CHX), and 2% peracetic acid (PAA) in disinfecting Resilon cones and to evaluate topographical changes microscopically under scanning electron microscope (SEM) after rapid chemical disinfection. Resilon cones were disinfected in an ultraviolet (UV) light chamber for 20 min and contaminated by immersing in a microbial suspension of Enterococcus faecalis for 30 min. The contaminated cones were then immersed in the 5.25% NaOCl, 2% CHX, and 2% PAA for 1 min, 5 min, and 10 min, separately. The cones were then incubated at 37°C in thioglycollate broth for 7 days and examined for turbidity. The samples showing turbidity were subcultured on blood agar and incubated at 37°C for 48 h. Gram staining was done to confirm that the cultured bacteria were E. faecalis. Surface changes of disinfected Resilon cones were evaluated under SEM. The data were analyzed statistically using Kruskal-Wallis, analysis of variance (ANOVA), and Mann-Whitney U-test. In eliminating E. faecalis, 5.25% NaOCl was most effective followed by 2% PAA and 2% CHX. Topographic examination of tested Resilon cones revealed some surface deposits after disinfection with 5.25% NaOCl and 2% CHX, whereas 2% PAA caused surface erosion. In disinfecting Resilon cones, 5.25% NaOCl is most effective followed by 2% PAA and 2% CHX.
NASA Astrophysics Data System (ADS)
Ibrahim, Marwa M.; Asal, Saad
2017-12-01
In the present work, x mol Ln3+ modified ZnO Nano-particles (Ln = Sm3+, Eu3+ and Gd3+ ions; x = 0.008, 0.015, 0.025, 0.03 and 0.05) were synthesized by precipitation method. These Nano-particles are characterized by different advanced techniques; such as X-ray diffraction (XRD), transmission electron microscope (TEM), energy dispersive spectroscopic (EDX), UV-Visible diffuse reflectance, and fluorescence (FL) spectroscopy. Doping by lanthanides improves the crystal, surface area, porosity, morphology, as well as the optical adsorption and emission of UV light properties of the prepared photo-catalysts. Photo-catalytic activity for the prepared Nano-materials was determined using both, fluorescent probe and dye methods. Results showed that the highly active Nano-particle is 0.025 Gd3+-ZnO. The highly active sample (0.025 mol Gd3+- ZnO) successfully mineralized textile dye and real refractory wastewater samples under sunlight illumination using CPC photo-reactor. Prepared photo-catalysts were also applied for water disinfection.
Harding, Alexander S.; Schwab, Kellogg J.
2012-01-01
We investigated the use of psoralens and limes to enhance solar disinfection of water (SODIS) using an UV lamp and natural sunlight experiments. SODIS conditions were replicated using sunlight, 2 L polyethylene terephthalate (PET) bottles, and tap water with Escherichia coli, MS2 bacteriophage, and murine norovirus (MNV). Psoralens and lime acidity both interact synergistically with UV radiation to accelerate inactivation of microbes. Escherichia coli was ablated > 6.1 logs by SODIS + Lime Slurry and 5.6 logs by SODIS + Lime Juice in 30-minute solar exposures, compared with a 1.5 log reduction with SODIS alone (N = 3; P < 0.001). MS2 was inactivated > 3.9 logs by SODIS + Lime Slurry, 1.9 logs by SODIS + Lime Juice, and 1.4 logs by SODIS in 2.5-hour solar exposures (N = 3; P < 0.05). MNV was resistant to SODIS, with < 2 log reductions after 6 hours. Efficacy of SODIS against human norovirus should be investigated further. PMID:22492137
Chlorine decay and bacterial inactivation kinetics in drinking water in the tropics.
Thøgersen, J; Dahi, E
1996-09-01
The decay of free chlorine (Cl2) and combined chlorine (mostly monochloramine: NH2Cl) and the inactivation of bacteria was examined in Dar es Salaam, Tanzania. Batch experiments, pilot-scale pipe experiments and full-scale pipe experiments were carried out to establish the kinetics for both decay and inactivation, and to compare the two disinfectants for use under tropical conditions. The decay of both disinfectants closely followed first order kinetics, with respect to the concentration of both disinfectant and disinfectant-consuming substances. Bacterial densities exhibited a kinetic pattern consisting of first order inactivation with respect to the density of the bacteria and the concentration of the disinfectant, and first order growth with respect to the bacterial density. The disinfection kinetic model takes the decaying concentration of the disinfectant into account. The decay rate constant for free chlorine was 114 lg(-1)h(-1), while the decay rate constant for combined chlorine was 1.84 lg(-1)h(-1) (1.6% of the decay rate for free chlorine). The average concentration of disinfectant consuming substances in the water phase was 2.6 mg Cl2/l for free chlorine and 5.6 mg NH2Cl/l for combined chlorine. The decay rate constant and the concentration of disinfectant consuming substances when water was pumped through pipes, depended on whether or not chlorination was continuous. Combined chlorine especially could clean the pipes of disinfectant consuming substances. The inactivation rate constant λ, was estimated at 3.06×10(4) lg(-1)h(-1). Based on the inactivation rate constant, and a growth rate constant determined in a previous study, the critical concentration of free chlorine was found to be 0.08 mg Cl2/l. The critical concentration is a value below which growth rates dominate over inactivation.
Efficacy of detergent and water versus bleach for disinfection of direct contact ophthalmic lenses.
Abbey, Ashkan M; Gregori, Ninel Z; Surapaneni, Krishna; Miller, Darlene
2014-06-01
Although manufacturers recommend cleaning ophthalmic lenses with detergent and water and then with a specific disinfectant, disinfectants are rarely used in ophthalmic practices. The aim of this pilot study was to evaluate the efficacy of detergent and water versus that of bleach, a recommended disinfectant, to eliminate common ocular bacteria and viruses from ophthalmic lenses. Three bacterial strains (Staphylococcus epidermidis, Corynebacterium straitum, and methicillin-resistant Staphylococcus aureus and 2 viral strains (adenovirus and herpes simplex virus [HSV] type-1) were individually inoculated onto 20 gonioscopy and laser lenses. The lenses were washed with detergent and water and then disinfected with 10% bleach. All the lenses were cultured after inoculation, after washing with detergent and water, and after disinfecting with the bleach. Bacterial cultures in thioglycollate broth were observed for 3 weeks, and viral cultures were observed for 2 weeks. The presence of viruses was also detected by multiplex polymerase chain reaction (PCR). All 20 lenses inoculated with S. epidermidis, C. straitum, adenovirus, and HSV-1 showed growth after inoculation but no growth after washing with detergent/water and after disinfecting with the bleach. All lenses showed positive HSV and adenovirus PCR results after inoculation and negative PCR results after washing with detergent/water and after disinfecting with bleach. All methicillin-resistant S. aureus-contaminated lenses showed growth after inoculation and no growth after washing with detergent and water. However, 1 lens showed positive growth after disinfecting with bleach. Cleaning with detergent and water seemed to effectively eliminate bacteria and viruses from the surface of contaminated ophthalmic lenses. Further studies are warranted to design practical disinfection protocols that minimize lens damage.
Kuch, Bertram; Lange, Claudia; Richter, Philipp; Kugele, Amélie; Minke, Ralf
2018-01-01
Effluent of a municipal wastewater treatment plant (WWTP) was treated on-site with the UV/chlorine (UV/HOCl) advanced oxidation process (AOP) using a pilot plant equipped with a medium pressure UV lamp with an adjustable performance of up to 1 kW. Results obtained from parallel experiments with the same pilot plant, where the state of the art UV/H2O2 AOP was applied, were compared regarding the removal of emerging contaminants (EC) and the formation of adsorbable organohalogens (AOX). Furthermore, the total estrogenic activity was measured in samples treated with the UV/chlorine AOP. At an energy consumption of 0.4 kWh/m3 (0.4 kW, 1 m3/h) and in a range of oxidant concentrations from 1 to 6 mg/L, the UV/chlorine AOP had a significantly higher EC removal yield than the UV/H2O2 AOP. With free available chlorine concentrations (FAC) in the UV chamber influent of at least 5 mg/L (11 mg/L of dosed Cl2), the total estrogenic activity could be reduced by at least 97%. To achieve a certain concentration of FAC in the UV chamber influent, double to triple the amount of dosed Cl2 was needed, resulting in AOX concentrations of up to 520 µg/L. PMID:29735959
Rott, Eduard; Kuch, Bertram; Lange, Claudia; Richter, Philipp; Kugele, Amélie; Minke, Ralf
2018-05-07
Effluent of a municipal wastewater treatment plant (WWTP) was treated on-site with the UV/chlorine (UV/HOCl) advanced oxidation process (AOP) using a pilot plant equipped with a medium pressure UV lamp with an adjustable performance of up to 1 kW. Results obtained from parallel experiments with the same pilot plant, where the state of the art UV/H₂O₂ AOP was applied, were compared regarding the removal of emerging contaminants (EC) and the formation of adsorbable organohalogens (AOX). Furthermore, the total estrogenic activity was measured in samples treated with the UV/chlorine AOP. At an energy consumption of 0.4 kWh/m³ (0.4 kW, 1 m³/h) and in a range of oxidant concentrations from 1 to 6 mg/L, the UV/chlorine AOP had a significantly higher EC removal yield than the UV/H₂O₂ AOP. With free available chlorine concentrations (FAC) in the UV chamber influent of at least 5 mg/L (11 mg/L of dosed Cl₂), the total estrogenic activity could be reduced by at least 97%. To achieve a certain concentration of FAC in the UV chamber influent, double to triple the amount of dosed Cl₂ was needed, resulting in AOX concentrations of up to 520 µg/L.
Smolle, C; Huss, F; Lindblad, M; Reischies, F; Tano, E
2018-01-01
Healthcare textiles are increasingly recognized as potential vehicles for transmission of hospital-acquired infections. This study tested the ability of an automated ultraviolet-C (UV-C) room disinfection device (Tru-D Smart UV-C) to decontaminate textiles inoculated with Enterococcus faecium in a clinical setting. Contaminated polycotton (50/50 polyester/cotton) swatches were distributed to predefined locations in a ward room and exposed to UV-C light. UV-C decontamination reduced E. faecium counts by a mean log 10 reduction factor of 1.37 (all P = 0.005, Wilcoxon signed rank test). UV-C decontamination may be a feasible adjunctive measure to conventional laundering to preserve the cleanliness of healthcare textiles in ward rooms. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Zamyadi, Arash; Sawade, Emma; Ho, Lionel; Newcombe, Gayle; Hofmann, Ron
2015-01-01
Cyanobacteria and their taste and odor (T&O) compounds are a growing concern in water sources globally. Geosmin and 2-methylisoborneol (MIB) are the most commonly detected T&O compounds associated with cyanobacterial presence in drinking water sources. The use of ultraviolet and hydrogen peroxide (H2O2) as an advanced oxidation treatment for T&O control is an emerging technology. However, residual H2O2 (>80% of the initial dose) has to be removed from water prior final disinfection. Recently, granular activated carbon (GAC) is used to remove H2O2 residual. The objective of this study is to assess the impact of H2O2 quenching and aging processes on GAC capacity for the removal of geosmin and MIB. Pilot columns with different types of GAC and presence/absence of H2O2 have been used for this study. H2O2 removal for the operational period of 6 months has no significant impact on GAC capacity to remove the geosmin and MIB from water.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walker, Ricardo W.; Brown, Richard S.; Deters, Katherine A.
Ultraviolet radiation (UVR) can be used as a tool to disinfect surgery tools used for implanting transmitters into fish. However, the use of UVR could possibly degrade monofilament suture material used to close surgical incisions. This research examined the effect of UVR on monofilament sutures to determine if they were compromised and negatively influenced tag and suture retention, incision openness, or tissue reaction. Eighty juvenile Chinook salmon Oncorhynchus tshawytscha were surgically implanted with an acoustic transmitter and a passive integrated transponder. The incision was closed with a single stitch of either a suture exposed to 20 doses of UV radiationmore » (5 minute duration per dose) or a new, sterile suture. Fish were then held for 28 d and examined under a microscope at day 7, 14, 21 and 28 for incision openness, ulceration, redness, and the presence of water mold. There was no significant difference between treatments for incision openness, redness, ulceration or the presence of water mold on any examination day. On day 28 post-surgery, there were no lost sutures; however, 2 fish lost their transmitters (one from each treatment). The results of this study do not show any differences in negative influences such as tissue response, suture retention or tag retention between a new sterile suture and a suture disinfected with UVR.« less
University Efforts on Non-PRASA Drinking Water Systems
In 2013 and 2014, the U.S. EPA and InterAmerican University of San German worked with water treatment operators from Patillas, Puerto Rico on the installation, training and testing of pretreatment/UV disinfection systems in the communities of La Sophia and Apeadero. Test water s...
UV-TUBE DESIGN CONCEPT FOR SUSTAINABLE, POINT-OF-USE WATER DISINFECTION
The 2002 World Health Organization (WHO) report on worldwide mortality indicates that waterborne illnesses associated with unsafe drinking water and poor sanitation are still a major cause of death in the developing world. Although a variety of methods exist for treating dr...
Evaluation of the potentials of humic acid removal in water by gas phase surface discharge plasma.
Wang, Tiecheng; Qu, Guangzhou; Ren, Jingyu; Yan, Qiuhe; Sun, Qiuhong; Liang, Dongli; Hu, Shibin
2016-02-01
Degradation of humic acid (HA), a predominant type of natural organic matter in ground water and surface waters, was conducted using a gas phase surface discharge plasma system. HA standard and two surface waters (Wetland, and Weihe River) were selected as the targets. The experimental results showed that about 90.9% of standard HA was smoothly removed within 40 min's discharge plasma treatment at discharge voltage 23.0 kV, and the removal process fitted the first-order kinetic model. Roles of some active species in HA removal were studied by evaluating the effects of solution pH and OH radical scavenger; and the results presented that O3 and OH radical played significant roles in HA removal. Scanning electron microscope (SEM) and FTIR analysis showed that HA surface topography and molecular structure were changed during discharge plasma process. The mineralization of HA was analyzed by UV-Vis spectrum, dissolved organic carbon (DOC), specific UV absorbance (SUVA), UV absorption ratios, and excitation-emission matrix (EEM) fluorescence. The formation of disinfection by-products during HA sample chlorination was also identified, and CHCl3 was detected as the main disinfection by-product, but discharge plasma treatment could suppress its formation to a certain extent. In addition, approximately 82.3% and 67.9% of UV254 were removed for the Weihe River water and the Wetland water after 40 min of discharge plasma treatment. Copyright © 2015 Elsevier Ltd. All rights reserved.
Oxidative degradation of endotoxin by advanced oxidation process (O3/H2O2 & UV/H2O2).
Oh, Byung-Taek; Seo, Young-Suk; Sudhakar, Dega; Choe, Ji-Hyun; Lee, Sang-Myeong; Park, Youn-Jong; Cho, Min
2014-08-30
The presence of endotoxin in water environments may pose a serious public health hazard. We investigated the effectiveness of advanced oxidative processes (AOP: O3/H2O2 and UV/H2O2) in the oxidative degradation of endotoxin. In addition, we measured the release of endotoxin from Escherichia coli following typical disinfection methods, such as chlorine, ozone alone and UV, and compared it with the use of AOPs. Finally, we tested the AOP-treated samples in their ability to induce tumor necrosis factor alpha (TNF-α) in mouse peritoneal macrophages. The production of hydroxyl radical in AOPs showed superior ability to degrade endotoxin in buffered solution, as well as water samples from Korean water treatment facilities, with the ozone/H2O2 being more efficient compared to UV/H2O2. In addition, the AOPs proved effective not only in eliminating E. coli in the samples, but also in endotoxin degradation, while the standard disinfection methods lead to the release of endotoxin following the bacteria destruction. Furthermore, in the experiments with macrophages, the AOPs-deactivated endotoxin lead to the smallest induction of TNF-α, which shows the loss of inflammation activity, compared to ozone treatment alone. In conclusion, these results suggest that AOPs offer an effective and mild method for endotoxin degradation in the water systems. Copyright © 2014 Elsevier B.V. All rights reserved.
Chourabi, Kalthoum; Campoy, Susana; Rodriguez, Jesus A; Kloula, Salma; Landoulsi, Ahmed; Chatti, Abdelwaheb
2017-11-01
Water UV disinfection remains extremely important, particularly in developing countries where drinking and reclaimed crop irrigation water may spread devastating infectious diseases. Enteric bacterial pathogens, among which Shigella, are possible contaminants of drinking and bathing water and foods. To study the effect of UV light on Shigella, four strains were exposed to different doses in a laboratory-made irradiation device, given that the ultraviolet radiation degree of inactivation is directly related to the UV dose applied to water. Our results showed that the UV-C rays are effective against all the tested Shigella strains. However, UV-C doses appeared as determinant factors for Shigella eradication. On the other hand, Shigella-survived strains changed their outer membrane protein profiles, secreted proteins, and lipopolysaccharides. Also, as shown by electron microscopy transmission, morphological alterations were manifested by an internal cytoplasm disorganized and membrane envelope breaks. Taken together, the focus of interest of our study is to know the adaptive mechanism of UV-C resistance of Shigella strains.
Designing plasmas for chronic wound disinfection
NASA Astrophysics Data System (ADS)
Nosenko, T.; Shimizu, T.; Morfill, G. E.
2009-11-01
Irradiation with low-temperature atmospheric-pressure plasma provides a promising method for chronic wound disinfection. To be efficient for this purpose, plasma should meet the following criteria: it should significantly reduce bacterial density in the wounded area, cause a long-term post-irradiation inhibition of bacterial growth, yet without causing any negative effect on human cells. In order to design plasmas that would satisfy these requirements, we assessed the relative contribution of different components with respect to bactericidal properties due to irradiation with argon plasma. We demonstrate that plasma-generated UV radiation is the main short-term sterilizing factor of argon plasma. On the other hand, plasma-generated reactive nitrogen species (RNS) and reactive oxygen species (ROS) cause a long-term 'after-irradiation' inhibition of bacterial growth and, therefore, are important for preventing wound recolonization with bacteria between two treatments. We also demonstrate that at certain concentrations plasma-generated RNS and ROS cause significant reduction of bacterial density, but have no adverse effect on human skin cells. Possible mechanisms of the different effects of plasma-generated reactive species on bacteria and human cells are discussed. The results of this study suggest that argon plasma for therapeutic purposes should be optimized in the direction of reducing the intensity of plasma-generated UV radiation and increasing the density of non-UV plasma products.
Leoni, E; Sanna, T; Zanetti, F; Dallolio, L
2015-12-01
The study aimed to assess the efficacy of an integrated water safety plan (WSP) in controlling Legionella re-growth in a respiratory hydrotherapy system located in a spa centre, supplied with sulphurous water, which was initially colonized by Legionella pneumophila. Heterotrophic plate counts, Pseudomonas aeruginosa, Legionella spp. were detected in water samples taken 6-monthly from the hydrotherapy equipment (main circuit, entry to benches, final outlets). On the basis of the results obtained by the continuous monitoring and the changes in conditions, the original WSP, including physical treatments of water and waterlines, environmental surveillance and microbiological monitoring, was integrated introducing a UV/ultrafiltration system. The integrated treatment applied to the sulphurous water (microfiltration/UV irradiation/ultrafiltration), waterlines (superheated stream) and distal outlets (descaling/disinfection of nebulizers and nasal irrigators), ensured the removal of Legionella spp. and P. aeruginosa and a satisfactory microbiological quality over time. The environmental surveillance was successful in evaluating the hazard and identifying the most suitable preventive strategies to avoid Legionella re-growth. Ultrafiltration is a technology to take into account in the control of microbial contamination of therapeutic spas, since it does not modify the chemical composition of the water, thus allowing it to retain its therapeutic properties.
Altered UV absorbance and cytotoxicity of chlorinated sunscreen agents.
Sherwood, Vaughn F; Kennedy, Steven; Zhang, Hualin; Purser, Gordon H; Sheaff, Robert J
2012-12-01
Sunscreens are widely utilized due to the adverse effects of ultraviolet (UV) radiation on human health. The safety of their active ingredients as well as that of any modified versions generated during use is thus of concern. Chlorine is used as a chemical disinfectant in swimming pools. Its reactivity suggests sunscreen components might be chlorinated, altering their absorptive and/or cytotoxic properties. To test this hypothesis, the UV-filters oxybenzone, dioxybenzone, and sulisobenzone were reacted with chlorinating agents and their UV spectra analyzed. In all cases, a decrease in UV absorbance was observed. Given that chlorinated compounds can be cytotoxic, the effect of modified UV-filters on cell viability was examined. Chlorinated oxybenzone and dioxybenzone caused significantly more cell death than unchlorinated controls. In contrast, chlorination of sulisobenzone actually reduced cytotoxicity of the parent compound. Exposing a commercially available sunscreen product to chlorine also resulted in decreased UV absorbance, loss of UV protection, and enhanced cytotoxicity. These observations show chlorination of sunscreen active ingredients can dramatically decrease UV absorption and generate derivatives with altered biological properties.
Liu, Wei; Wei, Dongbin; Liu, Qi; Du, Yuguo
2016-07-01
Benzophenones compounds (BPs) are widely used as UV filters, and have been frequently found in multiple environmental matrices. The residual of BPs in water would cause potential threats on ecological safety and human health. Chlorination disinfection is necessary in water treatment process, in which many chemicals remained in water would react with disinfectant chlorine and form toxic by-products. By using ultra performance liquid phase chromatography quadrupole time of flight mass spectrometer (UPLC-QTOF-MS), nuclear magnetic resonance (NMR), the transformation of 4-hydroxyl benezophenone (4HB) with free available chlorine (FAC) was characterized. Eight major products were detected and seven of them were identified. Transformation pathways of 4HB under acid, neutral, and alkaline conditions were proposed respectively. The transformation mechanisms involved electrophilic chlorine substitution of 4HB, Baeyer-Villiger oxidation of ketones, hydrolysis of esters and oxidative breakage of benzene ring. The orthogonal experiments of pH and dosages of disinfectant chlorine were conducted. The results suggested that pH conditions determined the occurrence of reaction types, and the dosages of disinfectant chlorine affected the extent of reactions. Photobacterium assay demonstrated that acute toxicity had significant increase after chlorination disinfection of 4HB. It was proved that 3,5-dichloro-4HB, one of the major transformation products, was responsible for the increasing acute toxicity after chlorination. It is notable that, 4HB at low level in real ambient water matrices could be transformed during simulated chlorination disinfection practice. Especially, two major products 3-chloro-4HB and 3,5-dichloro-4HB were detected out, implying the potential ecological risk after chlorination disinfection of 4HB. Copyright © 2016 Elsevier Ltd. All rights reserved.
WATER INGESTION DURING SWIMMING ACTIVITIES IN A POOL: A PILOT STUDY
Chloroisocyanurates are commonly added to outdoor swimming pools to stabilize chlorine disinfectants. The chloroisocyanurates decompose slowly to release chlorine and cyanuric acid. Studies conducted to determine if the chloroisocyanurates might be toxic to swimmers showed that...
Thomas, Simon F.; Rooks, Paul; Rudin, Fabian; Atkinson, Sov; Goddard, Paul; Bransgrove, Rachel M.; Mason, Paul T.; Allen, Michael J.
2014-01-01
We show in this study that the combination of a swirl flow reactor and an antimicrobial agent (in this case copper alginate beads) is a promising technique for the remediation of contaminated water in waste streams recalcitrant to UV-C treatment. This is demonstrated by comparing the viability of both common and UV-C resistant organisms in operating conditions where UV-C proves ineffective - notably high levels of solids and compounds which deflect UV-C. The swirl flow reactor is easy to construct from commonly available plumbing parts and may prove a versatile and powerful tool in waste water treatment in developing countries. PMID:25541706
The goal of this study is to estimate the risk of childhood febrile and gastrointestinal illnesses associated with drinking municipal water from a groundwater source. The risk estimate will be partitioned into two separate components— illness attributable to contaminated...
Formation of oxidation byproducts from ozonation of wastewater.
Wert, Eric C; Rosario-Ortiz, Fernando L; Drury, Doug D; Snyder, Shane A
2007-04-01
Disinfection byproduct (DBP) formation in tertiary wastewater was examined after ozonation (O(3)) and advanced oxidation with O(3) and hydrogen peroxide (O(3)/H(2)O(2)). O(3) and O(3)/H(2)O(2) were applied at multiple dosages to investigate DBP formation during coliform disinfection and trace contaminant oxidation. Results showed O(3) provided superior disinfection of fecal and total coliforms compared to O(3)/H(2)O(2). Color, UV absorbance, and SUVA were reduced by O(3) and O(3)/H(2)O(2), offering wastewater utilities a few potential surrogates to monitor disinfection or trace contaminant oxidation. At equivalent O(3) dosages, O(3)/H(2)O(2) produced greater concentrations of assimilable organic carbon (5-52%), aldehydes (31-47%), and carboxylic acids (12-43%) compared to O(3) alone, indicating that organic DBP formation is largely dependent upon hydroxyl radical exposure. Bromate formation occurred when O(3) dosages exceeded the O(3) demand of the wastewater. Bench-scale tests with free chlorine showed O(3) is capable of reducing total organic halide (TOX) formation potential by at least 20%. In summary, O(3) provided superior disinfection compared to O(3)/H(2)O(2) while minimizing DBP concentrations. These are important considerations for water reuse, aquifer storage and recovery, and advanced wastewater treatment applications.
Solar water disinfection (SODIS): a review from bench-top to roof-top.
McGuigan, Kevin G; Conroy, Ronán M; Mosler, Hans-Joachim; du Preez, Martella; Ubomba-Jaswa, Eunice; Fernandez-Ibañez, Pilar
2012-10-15
Solar water disinfection (SODIS) has been known for more than 30 years. The technique consists of placing water into transparent plastic or glass containers (normally 2L PET beverage bottles) which are then exposed to the sun. Exposure times vary from 6 to depending on the intensity of sunlight and sensitivity of the pathogens. Its germicidal effect is based on the combined effect of thermal heating of solar light and UV radiation. It has been repeatedly shown to be effective for eliminating microbial pathogens and reduce diarrhoeal morbidity including cholera. Since 1980 much research has been carried out to investigate the mechanisms of solar radiation induced cell death in water and possible enhancement technologies to make it faster and safer. Since SODIS is simple to use and inexpensive, the method has spread throughout the developing world and is in daily use in more than 50 countries in Asia, Latin America, and Africa. More than 5 million people disinfect their drinking water with the solar disinfection (SODIS) technique. This review attempts to revise all relevant knowledge about solar disinfection from microbiological issues, laboratory research, solar testing, up to and including real application studies, limitations, factors influencing adoption of the technique and health impact. Copyright © 2012 Elsevier B.V. All rights reserved.
Chandrappa, Mahesh Martur; Meharwade, Prasanna Mahadevasa; Srinivasan, Raghu; Bhandary, Shreetha; Nasreen, Farhat
2016-01-01
Aim: The objective of this study was to evaluate the effectiveness of 5.25% sodium hypochlorite (NaOCl), 2% chlorhexidine (CHX), and 2% peracetic acid (PAA) in disinfecting Resilon cones and to evaluate topographical changes microscopically under scanning electron microscope (SEM) after rapid chemical disinfection. Materials and Methods: Resilon cones were disinfected in an ultraviolet (UV) light chamber for 20 min and contaminated by immersing in a microbial suspension of Enterococcus faecalis for 30 min. The contaminated cones were then immersed in the 5.25% NaOCl, 2% CHX, and 2% PAA for 1 min, 5 min, and 10 min, separately. The cones were then incubated at 37°C in thioglycollate broth for 7 days and examined for turbidity. The samples showing turbidity were subcultured on blood agar and incubated at 37°C for 48 h. Gram staining was done to confirm that the cultured bacteria were E. faecalis. Surface changes of disinfected Resilon cones were evaluated under SEM. Statistical Analysis Used: The data were analyzed statistically using Kruskal-Wallis, analysis of variance (ANOVA), and Mann–Whitney U-test. Result: In eliminating E. faecalis, 5.25% NaOCl was most effective followed by 2% PAA and 2% CHX. Topographic examination of tested Resilon cones revealed some surface deposits after disinfection with 5.25% NaOCl and 2% CHX, whereas 2% PAA caused surface erosion. Conclusion: In disinfecting Resilon cones, 5.25% NaOCl is most effective followed by 2% PAA and 2% CHX. PMID:27099418
Feng, Zhe; Lu, Ruiqing; Yuan, Baoling; Zhou, Zhenming; Wu, Qingqing; Nguyen, Thanh H
2016-12-01
MS2 inactivation by UV irradiance was investigated with the focus on how the disinfection efficacy is influenced by bacteriophage MS2 aggregation and adsorption to particles in solutions with different compositions. Kaolinite and Microcystis aeruginosa were used as model inorganic and organic particles, respectively. In the absence of model particles, MS2 aggregates formed in either 1mM NaCl at pH=3 or 50-200mM ionic strength CaCl 2 solutions at pH=7 led to a decrease in the MS2 inactivation efficacy because the virions located inside the aggregate were protected from the UV irradiation. In the presence of kaolinite and Microcystis aeruginosa, MS2 adsorbed onto the particles in either 1mM NaCl at pH=3 or 50-200mM CaCl 2 solutions at pH=7. In contrast to MS2 aggregates formed without the presence of particles, more MS2 virions adsorbed on these particles were exposed to UV irradiation to allow an increase in MS2 inactivation. In either 1mM NaCl at pH from 4 to 8 or 2-200mM NaCl solutions at pH=7, the absence of MS2 aggregation and adsorption onto the model particles explained why MS2 inactivation was not influenced by pH, ionic strength, and the presence of model particles in these conditions. The influence of virus adsorption and aggregation on the UV disinfection efficiency found in this research suggests the necessity of accounting for particles and cation composition in virus inactivation for drinking water. Copyright © 2016 Elsevier B.V. All rights reserved.
Xiao, Y; Chu, X N; He, M; Liu, X C; Hu, J Y
2018-05-15
Ultraviolet (UV) light emission diode (LED), which is mercury free and theoretically more energy efficient, has now become an alternative to conventional UV lamps in water disinfection industry. In this research, the disinfection performance of a novel sequential process, UVA 365nm LED followed by UVC 265nm LED (UVA-UVC), was evaluated. The results revealed that the responses of different bacterial strains to UVA-UVC varied. Coupled with appropriate dosages of UVC, a 20 min UVA pre-radiation provided higher inactivations (log inactivation) of E. coli ATCC 11229, 15597 and 700891 by 1.2, 1.4 and 1.2 times, respectively than the sum of inactivations by UVA alone and UVC alone. On the contrary, the inactivation of E. coli ATCC 25922, the most UVC sensitive strain, decreased from 3 log to 1.8 log after UVA pre-radiation. A 30 min UVA pre-radiation did not affect the photo repair capacity of the four strains (n = 23, p > 0.1), but their dark repair ability was significantly inhibited (n = 14, p < 0.05). Mechanism study was conducted for two representative strains, E. coli ATCC 15597 and 25922 to understand the observed effect. The hypothesis that UVA pre-radiation promoted the yield of reactive oxygen species (ROS) was rejected. ELISA results indicated that 18% more cyclobutane pyrimidine dimers (CPD) were formed in E. coli ATCC 15597 with UVA pre-radiation (n = 3, p < 0.01), however, the CPD levels of E. coli ATCC 25922 was the same with or without UVA pre-radiation (n = 3, p > 0.01). Considering the results of both dark repair and CPD formation, it was concluded that the increased UV sensitivity of E. coli 15597 was originated from the increased CPD. For E. coli ATCC 25922, the enhanced UV resistance was attributed to the strain's adoption of a survival strategy, translesion DNA synthesis (TLS), when triggered by UVA pre-radiation. The study on UmuD protein, which is a key protein during TLS, confirmed this hypothesis. Copyright © 2018 Elsevier Ltd. All rights reserved.
Vieno, Niina M; Härkki, Heli; Tuhkanen, Tuula; Kronberg, Leif
2007-07-15
The occurrence of four beta blockers, one antiepileptic drug, one lipid regulator, four anti-inflammatories, and three fluoroquinolones was studied in a river receiving sewage effluents. All compounds but two of the fluoroquinolones were observed in the water above their limit of quantification concentrations. The highest concentrations (up to 107 ng L(-1)) of the compounds were measured during the winter months. The river water was passed to a pilot-scale drinking water treatment plant, and the elimination of the pharmaceuticals was followed during the treatment. The processes applied by the plant consisted of ferric salt coagulation, rapid sand filtration, ozonation, two-stage granular activated carbon filtration (GAC), and UV disinfection. Following the coagulation, sedimentation, and rapid sand filtration, the studied pharmaceuticals were found to be eliminated only by an average of 13%. An efficient elimination was found to take place during ozonation at an ozone dose of about 1 mg L(-1) (i.e., 0.2-0.4 mg of O3/ mg of TOC). Following this treatment, the concentrations of the pharmaceuticals dropped to below the quantification limits with the exception of ciprofloxacin. Atenolol, sotalol, and ciprofloxacin, the most hydrophilic of the studied pharmaceuticals, were not fully eliminated during the GAC filtrations. All in all, the treatment train was found to very effectively eliminate the pharmaceuticals from the rawwater. The only compound that was found to pass almost unaffected through all the treatment steps was ciprofloxacin.
The removal of disinfection by-product precursors from water with ceramic membranes.
Harman, B I; Koseoglu, H; Yigit, N O; Sayilgan, E; Beyhan, M; Kitis, M
2010-01-01
The main objective of this work was to investigate the effectiveness of ceramic ultrafiltration (UF) membranes with different pore sizes in removing natural organic matter (NOM) from model solutions and drinking water sources. A lab-scale, cross-flow ceramic membrane test unit was used in all experiments. Two different single-channel tubular ceramic membrane modules were tested with average pore sizes of 4 and 10 nm. The impacts of membrane pore size and pressure on permeate flux and the removals of UV(280 nm) absorbance, specific UV absorbance (SUVA(280 nm)), and dissolved organic carbon (DOC) were determined. Prior to experiments with model solutions and raw waters, clean water flux tests were conducted. UV(280) absorbance reductions ranged between 63 and 83% for all pressures and membranes tested in the raw water. More than 90% of UV(280) absorbance reduction was consistently achieved with both membranes in the model NOM solutions. Such high UV absorbance reductions are advantageous due to the fact that UV absorbing sites of NOM are known to be one of the major precursors to disinfection by-products (DBP) such as trihalomethanes and haloacetic acids. For both UF membranes, the ranges of DOC removals in the raw water and model NOM solutions were 55-73% and 79-91%, respectively. SUVA(280) value of the raw water decreased from 2 to about 1.5 L/mg-m by both membranes. For the model solutions, SUVA(280) values were consistently reduced to < or =1 L/mg-m levels after membrane treatment. As the SUVA(280) value of the NOM source increased, the extent of SUVA(280) reduction and DOC removal by the tested ceramic UF membranes also increased. The results overall indicated that ceramic UF membranes, especially the one with 4 nm average pore size, appear to be effective in removing organic matter and DBP precursors from drinking water sources with relatively high and sustainable permeate flux values.
40 CFR 141.720 - Inactivation toolbox components.
Code of Federal Regulations, 2014 CFR
2014-07-01
... treatment unit process with a measurable disinfectant residual level and a liquid volume. Under this... through reactor validation testing, as described in paragraph (d)(2) of this section. The UV dose values....0 12 11 143 (vii) 3.5 15 15 163 (viii) 4.0 22 22 186 (2) Reactor validation testing. Systems must...
Harvested rainwater quality before and after treatment in six ...
Rainwater harvesting (RWH) is an alternative method of providing water for indoor domestic use, but the water quality after treatment and distribution at individual residences is not well documented. In this study, water quality parameters were measured at the cistern and indoor cold-water taps of six residential RWH systems that use various treatment processes. Potential human pathogens (Mycobacterium avium, Mycobacterium intracellulare, Aspergillus flavus, Aspergillus fumigatus, and Aspergillus niger) were found frequently in cisterns and in treated rainwater delivered at the tap; Legionella pneumophila was not detected as frequently, but it persisted in a system after its first detection. The observed decreases in bacterial concentrations from the cistern to the tap after filtration/ ultraviolet (UV) treatment and distribution were less than expected; this suggests deficiencies in the effectiveness of the filtration/UV processes employed and/or degradation in water quality in the distribution system due to the absence of a disinfectant residual. Determination of the disinfection efficiency occuring in home treatment processes. Molecular analysis of rainwater before and after treatment. First study to include the monitoring of opportunistic fungal pathogens.
Hong, Huachang; Yan, Xiaoqing; Song, Xuhui; Qin, Yanyan; Sun, Hongjie; Lin, Hongjun; Chen, Jianrong; Liang, Yan
2017-07-15
The main objective of this study was to assess the effects of disinfection conditions on bromine incorporation into disinfection by-products (DBPs) during chlorination of water with low specific UV absorbance (SUVA). Five classes of DBPs were included: trihalomethanes (THMs), dihaloacetic acids (di-HAAs), trihaloacetic acids (tri-HAAs), dihaloacetonitriles (DHANs) and trihalonitromethanes (THNMs). Results showed that the bromine utilization in DBPs formation was positive related with reaction time, pH and temperature. On the other hand, the bromine substitution factors (BSFs) of DBPs were generally increased with pH (except tri-HAAs) and bromide concentration, but decreased with the reaction time, temperature and chlorine dose. Moreover, the BSFs values varied with DBP classes with the ranking being as following: THNMs≫DHANs≫tri-HAAs>THM≈di-HAAs. These results were mostly similar with the references, yet the pH effect on BSFs as well as the rank of BSFs for different DBP classes may differ with the specific UV absorbance of organic matter. Copyright © 2017 Elsevier B.V. All rights reserved.
Metal-free inactivation of E. coli O157:H7 by fullerene/C3N4 hybrid under visible light irradiation.
Ouyang, Kai; Dai, Ke; Chen, Hao; Huang, Qiaoyun; Gao, Chunhui; Cai, Peng
2017-02-01
Interest has grown in developing safe and high-performance photocatalysts based on metal-free materials for disinfection of bacterial pathogens under visible light irradiation. In this paper, the C 60 /C 3 N 4 and C 70 /C 3 N 4 hybrids were synthesized by a hydrothermal method, and characterized by X-ray diffraction (XRD), UV-vis diffuse reflection spectroscopy (UV-vis DRS), Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), and high revolution transmission electron microscope (HRTEM). The performance of photocatalytic disinfection was investigated by the inactivation of Escherichia coli O157:H7. Both C 60 /C 3 N 4 and C 70 /C 3 N 4 hybrids showed similar crystalline structure and morphology with C 3 N 4 ; however, the two composites exhibited stronger bacterial inactivation than C 3 N 4 . In particular, C 70 /C 3 N 4 showed the highest bactericidal efficiency and was detrimental to all E. coli O157:H7 in 4h irradiation. Compared to C 3 N 4 , the enhancement of photocatalytic activity of composites could be attributed to the effective transfer of the photoinduced electrons under visible light irradiation. Owing to the excellent performance of fullerenes (C 60 , C 70 )/C 3 N 4 composites, a visible light response and environmental friendly photocatalysts for disinfection were achieved. Copyright © 2016. Published by Elsevier Inc.
Xue, Shuang; Jin, Wujisiguleng; Zhang, Zhaohong; Liu, Hong
2017-07-01
The reductions of dissolved organic matter (DOM) and disinfection byproduct precursors in four full-scale wastewater treatment plants (WWTPs) (Liaoning Province, China) where different biological treatment processes were employed in winter were investigated. The total removal efficiencies of dissolved organic carbon (DOC), ultraviolet light at 254 nm (UV-254), trihalomethane formation potential (THMFP), and haloacetic acid formation potential (HAAFP) were in the range of 70.3-76.0%, 49.6-57.3%, 54.4-65.0%, and 53.7-63.8% in the four WWTPs, respectively. The biological treatment was the predominant process responsible for the removal of DOC, THMFP, and HAAFP in WWTPs. Differences in the reduction of UV-254 were not significant (p > 0.05) among biochemical reaction pool, secondary sedimentation tank, and disinfection tank. Biological aerated filter and suspended carrier activated sludge processes achieved higher DOM removal than the conventional active sludge and anaerobic-anoxic-oxic processes. Hydrophobic neutral and hydrophilic fraction were removed to a higher degree through biological treatment than the other three DOM fractions. HAAFP removal was more efficient than THMFP reduction during biological treatment. During primary treatment, fluorescent materials in secondary sedimentation tanks were preferentially removed, as compared to the bulk DOM. Humic-like fluorescent compounds were not readily eliminated during biological treatment. The fluorescent materials were more susceptible to chlorine than nonfluorescent compounds. Copyright © 2017. Published by Elsevier Ltd.
Enhanced drinking water supply through harvested rainwater treatment
NASA Astrophysics Data System (ADS)
Naddeo, Vincenzo; Scannapieco, Davide; Belgiorno, Vincenzo
2013-08-01
Decentralized drinking water systems represent an important element in the process of achieving the Millennium Development Goals, as centralized systems are often inefficient or nonexistent in developing countries. In those countries, most water quality related problems are due to hygiene factors and pathogens. A potential solution might include decentralized systems, which might rely on thermal and/or UV disinfection methods as well as physical and chemical treatments to provide drinking water from rainwater. For application in developing countries, decentralized systems major constraints include low cost, ease of use, environmental sustainability, reduced maintenance and independence from energy sources. This work focuses on an innovative decentralized system that can be used to collect and treat rainwater for potable use (drinking and cooking purposes) of a single household, or a small community. The experimented treatment system combines in one compact unit a Filtration process with an adsorption step on GAC and a UV disinfection phase in an innovative design (FAD - Filtration Adsorption Disinfection). All tests have been carried out using a full scale FAD treatment unit. The efficiency of FAD technology has been discussed in terms of pH, turbidity, COD, TOC, DOC, Escherichia coli and Total coliforms. FAD technology is attractive since it provides a total barrier for pathogens and organic contaminants, and reduces turbidity, thus increasing the overall quality of the water. The FAD unit costs are low, especially if compared to other water treatment technologies and could become a viable option for developing countries.
Disinfection by-products in ballast water treatment: an evaluation of regulatory data.
Werschkun, Barbara; Sommer, Yasmin; Banerji, Sangeeta
2012-10-15
To reduce the global spread of invasive aquatic species, international regulations will soon require reductions of the number of organisms in ballast water discharged by ships. For this purpose, ballast water treatment systems were developed and approved by an international procedure. These systems rely on established water treatment principles which, to different degrees, have been proven to generate disinfection by-products with hazardous properties but have only scarcely been investigated in marine environments. Our study evaluates the publicly available documentation about approved ballast water treatment systems with regard to by-product formation. The most commonly employed methods are chlorination, ozonation, and ultraviolet (UV) irradiation. Chlorination systems generate trihalomethanes, halogenated acetic acids, and bromate in substantially larger quantities than reported for other areas of application. Levels are highest in brackish water, and brominated species predominate, in particular bromoform and dibromoacetic acid. Ozonation, which is less frequently utilized, produces bromoform in lower concentrations but forms higher levels of bromate, both of which were effectively reduced by active carbon treatment. In systems based on UV radiation, medium pressure lamps are employed as well as UV-induced advanced oxidation. For all UV systems, by-product formation is reported only occasionally. The most notable observations were small increases in nitrite, hydrogen peroxide, halogenated methanes and acetic acids. The assessment of by-product formation during ballast water treatment is limited by the lacking completeness and quality of available information. This concerns the extent and statistical characterisation of chemical analysis as well as the documentation of the test water parameters. Copyright © 2012 Elsevier Ltd. All rights reserved.
Tamplin, M L; Capers, G M
1992-05-01
Vibrio vulnificus is an estuarine bacterium which can cause opportunistic infections in humans consuming raw Gulf Coast oysters, Crassostrea virginica. Although V. vulnificus is known as a ubiquitous organism in the Gulf of Mexico, its ecological relationship with C. virginica has not been adequately defined. The objective of the present study was to test the hypothesis that V. vulnificus is a persistent microbial flora of oysters and unamenable to traditional methods of controlled purification, such as UV light depuration. Experimental depuration systems consisted of aquaria containing temperature-controlled seawater treated with UV light and 0.2-microns-pore-size filtration. V. vulnificus was enumerated in seawater, oyster shell biofilms, homogenates of whole oyster meats, and tissues including the hemolymph, digestive region, gills, mantle, and adductor muscle. Results showed that depuration systems conducted at temperatures greater than 23 degrees C caused V. vulnificus counts to increase in oysters, especially in the hemolymph, adductor muscle, and mantle. Throughout the process, depuration water contained high concentrations of V. vulnificus, indicating that the disinfection properties of UV radiation and 0.2-microns-pore-size filtration were less than the rate at which V. vulnificus was released into seawater. Approximately 10(5) to 10(6) V. vulnificus organisms were released from each oyster per hour, with 0.05 to 35% originating from shell surfaces. These surfaces contained greater than 10(3) V. vulnificus organisms per cm2. In contrast, when depuration seawater was maintained at 15 degrees C, V. vulnificus was not detected in seawater and multiplication in oyster tissues was inhibited.
Degradation of acrylamide by the UV/chlorine advanced oxidation process.
Gao, Ze-Chen; Lin, Yi-Li; Xu, Bin; Pan, Yang; Xia, Sheng-Ji; Gao, Nai-Yun; Zhang, Tian-Yang; Chen, Ming
2017-11-01
The degradation of acrylamide (AA) during UV/chlorine advanced oxidation process (AOP) was investigated in this study. The degradation of AA was negligible during UV irradiation alone. However, AA could be effectively degraded and mineralized during UV/chlorination due to the generation of hydroxyl radicals (OH). The degradation kinetics of AA during UV/chlorination fitted the pseudo-first order kinetics with the rate constant between AA and OH radicals being determined as 2.11 × 10 9 M -1 s -1 . The degradation rate and mineralization of AA during UV/chlorination were significantly promoted at acidic conditions as well as increasing chlorine dosage. The volatile degradation products of AA during UV/chlorination were identified using gas chromatography-mass spectrometry and the degradation pathways were then proposed accordingly. The formation of disinfection by-products (DBPs) in Milli-Q water and tap water during UV/chlorination of AA was also investigated. The DBPs included chloroform, dichloroacetonitrile, trichloroacetonitrile, 2,2-dichloroacetamide and 2,2,2-trichloroacetamide. Furthermore, the variations of AA degradation during UV/chlorination in different real water samples were evaluated. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Bradie, Johanna; Gianoli, Claudio; He, Jianjun; Lo Curto, Alberto; Stehouwer, Peter; Veldhuis, Marcel; Welschmeyer, Nick; Younan, Lawrence; Zaake, André; Bailey, Sarah
2018-03-01
Non-indigenous species seriously threaten native biodiversity. To reduce establishments, the International Maritime Organization established the Convention for the Control and Management of Ships' Ballast Water and Sediments which limits organism concentrations at discharge under regulation D-2. Most ships will comply by using on-board treatment systems to disinfect their ballast water. Port state control officers will need simple, rapid methods to detect compliance. Appropriate monitoring methods may be dependent on treatment type, since different treatments will affect organisms by a variety of mechanisms. Many indicative tools have been developed, but must be examined to ensure the measured variable is an appropriate signal for the response of the organisms to the applied treatment. We assessed the abilities of multiple analytic tools to rapidly detect the effects of a ballast water treatment system based on UV disinfection. All devices detected a large decrease in the concentrations of vital organisms ≥ 50 μm and organisms < 10 μm (mean 82.7-99.7% decrease across devices), but results were more variable for the ≥ 10 to < 50 μm size class (mean 9.0-99.9% decrease across devices). Results confirm the necessity to choose tools capable of detecting the damage inflicted on living organisms, as examined herein for UV-C treatment systems.
NASA Astrophysics Data System (ADS)
Lizotte, Todd
2010-08-01
A novel laser beam shaping system was designed to demonstrate the potential of using high power UV laser sources for large scale disinfection of liquids used in the production of food products, such as juices, beer, milk and other beverage types. The design incorporates a patented assembly of optical components including a diffractive beam splitting/shaping element and a faceted pyramidal or conically shaped Lambertian diffuser made from a compression molded PTFE compounds. When properly sintered to an appropriate density, as an example between 1.10 and 1.40 grams per cubic centimeter, the compressed PTFE compounds show a ~99% reflectance at wavelengths ranging from 300 nm to 1500 nm, and a ~98.5% refection of wavelengths from 250 nm to 2000 nm [1]. The unique diffuser configuration also benefits from the fact that the PTFE compounds do not degrade when exposed to ultraviolet radiation as do barium sulfate materials and silver or aluminized mirror coatings [2]. These components are contained within a hermetically sealed quartz tube. Once assembled a laser beam is directed through one end of the tube. This window takes the form of a computer generated diffractive splitter or other diffractive shaper element to split the laser beam into a series of spot beamlets, circular rings or other geometric shapes. As each of the split beamlets or rings cascade downward, they illuminate various points along the tapered PTFE cone or faceted pyramidal form. As they strike the surface they each diffuse in a Lambertian reflectance pattern creating a pseudo-uniform circumferential illuminator along the length of the quartz tube enclosing the assembly. The compact tubular structure termed Longitudinal Illuminated Diffuser (LID) provides a unique UV disinfection source that can be placed within a centrifugal reactor or a pipe based reactor chamber. This paper will review the overall design principle, key component design parameters, preliminary analytic and bench operational testing results.
Urbain, V; Wright, P; Thomas, M
2001-01-01
Stringent effluent quality guidelines are progressively implemented in coastal and sensitive areas in Australia. Biological Nutrient Removal (BNR) plants are becoming a standard often including a tertiary treatment for disinfection. The BNR plant in Noosa - Queensland is designed to produce a treated effluent with less than 5 mg/l of BOD5, 5 mg/l of total nitrogen, 1 mg/l of total phosphorus, 5 mg/l of suspended solids and total coliforms of less than 10/100 ml. A flexible multi-stage biological process with a prefermentation stage, followed by sand filtration and UV disinfection was implemented to achieve this level of treatment. Acetic acid is added for phosphorus removal because: i) the volatile fatty acids (VFA) concentration in raw wastewater varies a lot, and ii) the prefermenter had to be turned off due to odor problems on the primary sedimentation tanks. An endogenous anoxic zone was added to the process to further reduce the nitrate concentration. This resulted in some secondary P-release events, a situation that happens when low nitrate and low phosphorus objectives are targeted. Long-term performance data and specific results on nitrogen removal and disinfection are presented in this paper.
The role of visible light active TiO2 specimens on the solar photocatalytic disinfection of E. coli.
Birben, Nazmiye Cemre; Tomruk, Ayse; Bekbolet, Miray
2017-05-01
Solar photocatalytic disinfection efficiency of novel visible light activated (VLA) photocatalysts was evaluated with the aim of assessing inactivation of Escherichia coli as the pathogen indicator organism present in drinking water. Influence of humic acid (HA) on the photocatalytic disinfection efficiency of the specified VLA TiO 2 specimens i.e., N-doped, Se-doped, and Se-N co-doped TiO 2 was also investigated. Photocatalytic disinfection efficiency was assessed by the enumeration of bacteria following selected irradiation periods. Degradation and compositional changes in organic matter (OM) was also tracked by means of UV-vis and advanced fluorescence spectroscopic (EEM features) parameters. Photocatalytic mineralization of the organic matter was followed by dissolved organic carbon contents. Presence of HA as a model organic compound of natural organic matter (NOM) displayed a retardation effect on solar photocatalytic abatement of E. coli. However, no distinctly different effect was observed under solar photolytic conditions due to the presence of HA. Regrowth of E. coli could not be assessed under the specified experimental conditions. A comparison was introduced with respect to the use of undoped TiO 2 P-25 as the photocatalyst.
Enhanced visible-light-driven photocatalytic bacteria disinfection by g-C3N4-AgBr.
Deng, Jun; Liang, Jialiang; Li, Mian; Tong, Meiping
2017-04-01
g-C 3 N 4 -AgBr was synthesized by depositing AgBr nanoparticles onto g-C 3 N 4 . Scanning electron microscopy (SEM), Transmission electron microscope (TEM), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), UV-vis diffuse reflectance spectra (DRS) and Photoluminescence (PL) spectra were employed to characterize the as-synthesized photocatalysts. The disinfection activities towards representative Gram-negative strain E. coli and Gram-positive strain S. aureus were examined under visible light irradiation. Complete inactivation of 3×10 6 CFU/mL viable cell density was reached in 60min for E. coli and 150min for S. aureus, respectively. Ag + released from the photocatalysts did not contribute to the photocatalytic disinfection process. Direct contact of g-C 3 N 4 -AgBr composites and bacterial cells, as well as the presence of O 2 was indispensable for the cell inactivation. Photo-generated holes, surface bounded OH, and indirect generation of intracellular active species played important roles in disinfection process of g-C 3 N 4 -AgBr under visible light irradiation. The disruption of outside structure of cells as well as inner cell injury led to the inactivation. High pH condition led to increasing the cell disinfection due to the generation of surface bounded OH. Copyright © 2017 Elsevier B.V. All rights reserved.
Electric discharge in water as a source of UV radiation, ozone and hydrogen peroxide
NASA Astrophysics Data System (ADS)
Anpilov, A. M.; Barkhudarov, E. M.; Bark, Yu B.; Zadiraka, Yu V.; Christofi, M.; Kozlov, Yu N.; Kossyi, I. A.; Kop'ev, V. A.; Silakov, V. P.; Taktakishvili, M. I.; Temchin, S. M.
2001-03-01
Results are presented from investigations of multispark electric discharge in water excited along multielectrode metal-dielectric systems with gas supply into the interelectrode gaps. The intensity distribution of discharge radiation in the region covering the biologically active soft UV (190≤λ≤430 nm) has been determined and the absolute number of quanta in this wavelength interval has been measured. The potentiality of the slipping surface discharge in water for its disinfection is analysed. The energy expenditure for water cleansing is estimated to be as low as ~10-4 kWh l-1.
Jelden, Katelyn C; Gibbs, Shawn G; Smith, Philip W; Hewlett, Angela L; Iwen, Peter C; Schmid, Kendra K; Lowe, John J
2017-06-01
An ultraviolet germicidal irradiation (UVGI) generator (the TORCH, ClorDiSys Solutions, Inc.) was used to compare the disinfection of surface coupons (plastic from a bedrail, stainless steel, and chrome-plated light switch cover) in a hospital room with walls coated with ultraviolet (UV)-reflective paint (Lumacept) or standard paint. Each surface coupon was inoculated with methicillin-resistant Staphylococcus aureus (MRSA) or vancomycin-resistant Enterococcus faecalis (VRE), placed at 6 different sites within a hospital room coated with UV-reflective paint or standard paint, and treated by 10 min UVC exposure (UVC dose of 0-688 mJ/cm 2 between sites with standard paint and 0-553 mJ/cm 2 with UV-reflective paint) in 8 total trials. Aggregated MRSA concentrations on plastic bedrail surface coupons were reduced on average by 3.0 log 10 (1.8 log 10 Geometric Standard Deviation [GSD]) with standard paint and 4.3 log 10 (1.3 log 10 GSD) with UV-reflective paint (p = 0.0005) with no significant reduction differences between paints on stainless steel and chrome. Average VRE concentrations were reduced by ≥4.9 log 10 (<1.2 log 10 GSD) on all surface types with UV-reflective paint and ≤4.1 log 10 (<1.7 log 10 GSD) with standard paint (p < 0.05). At 5 aggregated sites directly exposed to UVC light, MRSA concentrations on average were reduced by 5.2 log 10 (1.4 log 10 GSD) with standard paint and 5.1 log 10 (1.2 log 10 GSD) with UV-reflective paint (p = 0.017) and VRE by 4.4 log 10 (1.4 log 10 GSD) with standard paint and 5.3 log 10 (1.1 log 10 GSD) with UV-reflective paint (p < 0.0001). At one indirectly exposed site on the opposite side of the hospital bed from the UVGI generator, MRSA concentrations on average were reduced by 1.3 log 10 (1.7 log 10 GSD) with standard paint and 4.7 log 10 (1.3 log 10 GSD) with UV-reflective paint (p < 0.0001) and VRE by 1.2 log 10 (1.5 log 10 GSD) with standard paint and 4.6 log 10 (1.1 log 10 GSD) with UV-reflective paint (p < 0.0001). Coating hospital room walls with UV-reflective paint enhanced UVGI disinfection of nosocomial bacteria on various surfaces compared to standard paint, particularly at a surface placement site indirectly exposed to UVC light.
Background: There is an increased interest in the application of microbial electrochemical cell (MEC) for the recovery of value-added products such as hydrogen gas and hydrogen peroxide (H2O2) from wastewater. H2O2 has strong oxidation capability and produces hydroxyl radicals wh...
There is an increased interest in the application of microbial electrochemical cell (MEC) for the recovery of value-added products such as hydrogen gas and hydrogen peroxide (H2O2) from wastewater. H2O2 has strong oxidation capability and produces hydroxyl radicals when coupled w...
Szczawiński, J; Tomaszewski, H; Jackowska-Tracz, A; Szczawińska, M E
2011-01-01
The aim of this study was to determine and compare the antimicrobial activity of UV radiation of wavelength 253.7 nm (used in typical germicidal lamps) against Staphylococcus aureus on the surfaces of conventionally produced white ceramic wall tiles (matt and shiny) and the same tiles coated with TiO2 using three different methods: RF diode sputtering, atmospheric pressure chemical vapour deposition (APCVD) and spray pyrolysis deposition (SPD). Results clearly indicate that the bactericidal action of UV radiation is much stronger on the surfaces of tiles coated with TiO2 than on the tiles uncovered. The strongest bactericidal effect of UV radiation was found for film prepared by APCVD. Results of experiments for shiny and matt tiles did not differ statistically. The use of ceramic wall tiles coated with TiO2 films in hospitals, veterinary clinics, laboratories, food processing plants and other places where UV radiation is applied for disinfection should greatly improve the efficiency of this treatment.
Milly, P J; Toledo, R T; Chen, J; Kazem, B
2007-11-01
Ultraviolet (UV)-induced chemical reactions and inactivation of microorganisms in transparent and opaque fluids are strongly dependent upon the homogenous exposure of the target species to the UV irradiation. Current UV technologies used in water disinfection and food preservation applications have limited efficacy due to suspended particles shading target species. An Ultraviolet-Shockwave Power Reactor (UV-SPR) consisting of an inner rotating rotor and a stationary quartz housing and 2 end plates was used to induce 'controlled cavitation.' Eight UV low-pressure mercury lamps spaced uniformly were installed lengthwise around the quartz housing periphery. A KI to I(3) (-)chemical dosimeter for UV was used to quantify photons received by fluid in the annular space of the SPR. UV dose (J/m(2)) increased from 97 J/m(2) at 0 rpm to over 700 J/m(2) for SPR speeds above 2400 rpm. Inactivation of E. coli 25922 in apple juice and skim milk in the UV-SPR at exit temperatures below 45 degrees C was greater than 4.5 and 3 logs, respectively. The UV-SPR system proved successful in increasing the mass transfer of transparent and opaque fluid to the UV irradiated surface.
A PILOT STUDY TO DETERMINE THE WATER VOLUME INJESTED BY RECREATIONAL SWIMMERS
The volume of water ingested by recreational swimmers is unknown. Previous estimates by a number of investigators range from 10mL to 100mL. These estimates, however, are unsupported by empirical data. Many outdoor swimming pools are disinfected using cyanuric acid stabilized c...
INACTIVATION KINETICS OF MONOCHLORAMINE ON MONODISPERSED HEPATITIS A VIRUS AND MS2
The purpose of this study was to further characterize the disinfecting capabilities of preformed monochloramine using hepatitis A virus and the model coliphage MS2. he EPA has identified the latter virus as a model organism in developing CT values and conducting pilot plant studi...
Zhang, Ruochun; Meng, Tan; Huang, Ching-Hua; Ben, Weiwei; Yao, Hong; Liu, Ruini; Sun, Peizhe
2018-06-15
The combination of chlorine and UV (i.e. chlorine-UV process) has been attracting more attentions in recent years due to its ready incorporation into existing water treatment facilities to remove PPCPs. However, limited information is available on the impact of total ammonia nitrogen (TAN). This study investigated two model PPCPs, N,N-diethyl-3-toluamide (DEET) and caffeine (CAF), in the two stages of chlorine-UV process (i.e. chlorination and UV/chlor(am)ine) to elucidate the impact of TAN. During chlorination, the degradation of DEET and CAF was positively correlated with the overall consumption of total chlorine by TAN. Reactive nitrogen intermediates, including HNO/NO- and ONOOH/ONOO-, along with OH were identified as major contributors to the removal of DEET and CAF. During UV irradiation, DEET and CAF were degraded under UV/chlorine or UV/NH2Cl conditions. OH and Cl were the major reactive species to degrade DEET and CAF under UV/NH2Cl conditions, whereas OCl played a major role for degrading CAF under UV/chlorine conditions. Numerical models were developed to predict the removal of DEET and CAF under chlorination-UV process. Chlorinated disinfection byproducts were detected. Overall, this study presented kinetic features and mechanistic insights on the degradation of PPCPs under chlorine-UV process in ammoniacal water.
Luprano, Maria Laura; De Sanctis, Marco; Del Moro, Guido; Di Iaconi, Claudio; Lopez, Antonio; Levantesi, Caterina
2016-11-15
In order to mitigate the potential effects on the human health which are associated to the use of treated wastewater in agriculture, antibiotic resistance genes (ARGs) are required to be carefully monitored in wastewater reuse processes and their spread should be prevented by the development of efficient treatment technologies. Objective of this study was the assessment of ARGs reduction efficiencies of a novel technological treatment solution for agricultural reuse of municipal wastewaters. The proposed solution comprises an advanced biological treatment (Sequencing Batch Biofilter Granular Reactor, SBBGR), analysed both al laboratory and pilot scale, followed by sand filtration and two different disinfection final stages: ultraviolet light (UV) radiation and peracetic acid (PAA) treatments. By Polymerase Chain Reaction (PCR), the presence of 9 ARGs (ampC, mecA, ermB, sul1, sul2, tetA, tetO, tetW, vanA) were analysed and by quantitative PCR (qPCR) their removal was determined. The obtained results were compared to the reduction of total bacteria (16S rDNA gene) and of a faecal contamination indicator (Escherichia coli uidA gene). Only four of the analysed genes (ermB, sul1, sul2, tetA) were detected in raw wastewater and their abundance was estimated to be 3.4±0.7 x10(4) - 9.6±0.5 x10(9) and 1.0±0.3 x10(3) to 3.0±0.1 x10(7) gene copies/mL in raw and treated wastewaters, respectively. The results show that SBBGR technology is promising for the reduction of ARGs, achieving stable removal performance ranging from 1.0±0.4 to 2.8±0.7 log units, which is comparable to or higher than that reported for conventional activated sludge treatments. No reduction of the ARGs amount normalized to the total bacteria content (16S rDNA), was instead obtained, indicating that these genes are removed together with total bacteria and not specifically eliminated. Enhanced ARGs removal was obtained by sand filtration, while no reduction was achieved by both UV and PAA disinfection treatments tested in our study. Copyright © 2016 Elsevier B.V. All rights reserved.
Kheyrandish, Ataollah; Mohseni, Madjid; Taghipour, Fariborz
2018-06-15
Determining fluence is essential to derive the inactivation kinetics of microorganisms and to design ultraviolet (UV) reactors for water disinfection. UV light emitting diodes (UV-LEDs) are emerging UV sources with various advantages compared to conventional UV lamps. Unlike conventional mercury lamps, no standard method is available to determine the average fluence of the UV-LEDs, and conventional methods used to determine the fluence for UV mercury lamps are not applicable to UV-LEDs due to the relatively low power output, polychromatic wavelength, and specific radiation profile of UV-LEDs. In this study, a method was developed to determine the average fluence inside a water suspension in a UV-LED experimental setup. In this method, the average fluence was estimated by measuring the irradiance at a few points for a collimated and uniform radiation on a Petri dish surface. New correction parameters were defined and proposed, and several of the existing parameters for determining the fluence of the UV mercury lamp apparatus were revised to measure and quantify the collimation and uniformity of the radiation. To study the effect of polychromatic output and radiation profile of the UV-LEDs, two UV-LEDs with peak wavelengths of 262 and 275 nm and different radiation profiles were selected as the representatives of typical UV-LEDs applied to microbial inactivation. The proper setup configuration for microorganism inactivation studies was also determined based on the defined correction factors.
Recent advances in drinking water disinfection: successes and challenges.
Ngwenya, Nonhlanhla; Ncube, Esper J; Parsons, James
2013-01-01
Drinking water is the most important single source of human exposure to gastroenteric diseases, mainly as a result of the ingestion of microbial contaminated water. Waterborne microbial agents that pose a health risk to humans include enteropathogenic bacteria, viruses, and protozoa. Therefore, properly assessing whether these hazardous agents enter drinking water supplies, and if they do, whether they are disinfected adequately, are undoubtedly aspects critical to protecting public health. As new pathogens emerge, monitoring for relevant indicator microorganisms (e.g., process microbial indicators, fecal indicators, and index and model organisms) is crucial to ensuring drinking water safety. Another crucially important step to maintaining public health is implementing Water Safety Plans (WSPs), as is recommended by the current WHO Guidelines for Drinking Water Quality. Good WSPs include creating health-based targets that aim to reduce microbial risks and adverse health effects to which a population is exposed through drinking water. The use of disinfectants to inactivate microbial pathogens in drinking water has played a central role in reducing the incidence of waterborne diseases and is considered to be among the most successful interventions for preserving and promoting public health. Chlorine-based disinfectants are the most commonly used disinfectants and are cheap and easy to use. Free chlorine is an effective disinfectant for bacteria and viruses; however, it is not always effective against C. parvum and G. lamblia. Another limitation of using chlorination is that it produces disinfection by-products (DBPs), which pose potential health risks of their own. Currently, most drinking water regulations aggressively address DBP problems in public water distribution systems. The DBPs of most concern include the trihalomethanes (THMs), the haloacetic acids (HAAs), bromate, and chlorite. However, in the latest edition of the WHO Guidelines for Drinking Water Quality, it is recommended that water disinfection should never be compromised by attempting to control DBPs. The reason for this is that the risks of human illness and death from pathogens in drinking water are much greater than the risks from exposure to disinfectants and disinfection by-products. Nevertheless, if DBP levels exceed regulatory limits, strategies should focus on eliminating organic impurities that foster their formation, without compromising disinfection. As alternatives to chlorine, disinfectants such as chloramines, ozone, chlorine dioxide, and UV disinfection are gaining popularity. Chlorine and each of these disinfectants have individual advantage and disadvantage in terms of cost, efficacy-stability, ease of application, and nature of disinfectant by-products (DBPs). Based on efficiency, ozone is the most efficient disinfectant for inactivating bacteria, viruses, and protozoa. In contrast, chloramines are the least efficient and are not recommended for use as primary disinfectants. Chloramines are favored for secondary water disinfection, because they react more slowly than chlorine and are more persistent in distribution systems. In addition, chloramines produce lower DBP levels than does chlorine, although microbial activity in the distribution system may produce nitrate from monochloramine, when it is used as a residual disinfectant, Achieving the required levels of water quality, particularly microbial inactivation levels, while minimizing DBP formation requires the application of proper risk and disinfection management protocols. In addition, the failure of conventional treatment processes to eliminate critical waterborne pathogens in drinking water demand that improved and/or new disinfection technologies be developed. Recent research has disclosed that nanotechnology may offer solutions in this area, through the use of nanosorbents, nanocatalysts, bioactive nanoparticles, nanostructured catalytic membranes, and nanoparticle-enhanced filtration.
Rattanakul, Surapong; Oguma, Kumiko
2018-03-01
To demonstrate the effectiveness of UV light-emitting diodes (UV-LEDs) to disinfect water, UV-LEDs at peak emission wavelengths of 265, 280, and 300 nm were adopted to inactivate pathogenic species, including Pseudomonas aeruginosa and Legionella pneumophila, and surrogate species, including Escherichia coli, Bacillus subtilis spores, and bacteriophage Qβ in water, compared to conventional low-pressure UV lamp emitting at 254 nm. The inactivation profiles of each species showed either a linear or sigmoidal survival curve, which both fit well with the Geeraerd's model. Based on the inactivation rate constant, the 265-nm UV-LED showed most effective fluence, except for with E. coli which showed similar inactivation rates at 265 and 254 nm. Electrical energy consumption required for 3-log 10 inactivation (E E,3 ) was lowest for the 280-nm UV-LED for all microbial species tested. Taken together, the findings of this study determined the inactivation profiles and kinetics of both pathogenic bacteria and surrogate species under UV-LED exposure at different wavelengths. We also demonstrated that not only inactivation rate constants, but also energy efficiency should be considered when selecting an emission wavelength for UV-LEDs. Copyright © 2017 Elsevier Ltd. All rights reserved.
Hébert, N; Gagné, F; Cejka, P; Bouchard, B; Hausler, R; Cyr, D G; Blaise, C; Fournier, M
2008-08-01
Municipal sewage effluents are complex mixtures that are known to compromise the health condition of aquatic organisms. The aim of this study was to evaluate the impacts of various wastewater disinfection processes on the immune system of juvenile rainbow trout (Oncorhynchus mykiss). The trout were exposed to a primary-treated effluent for 28 days before and after one of each of the following treatments: ultraviolet (UV) radiation, ozonation and peracetic acid. Immune function was characterized in leucocytes from the anterior head kidney by the following three parameters: phagocytosis activity, natural cytotoxic cells (NCC) function and lymphocyte (B and T) proliferation assays. The results show that the fish mass to length ratio was significantly decreased for the primary-treated and all three disinfection processes. Exposure to the primary-treated effluent led to a significant increase in macrophage-related phagocytosis; the addition of a disinfection step was effective in removing this effect. Both unstimulated and mitogen-stimulated T lymphocyte proliferation in fish decreased dramatically in fish exposed to the ozonated effluent compared to fish exposed to either the primary-treated effluent or to aquarium water. Stimulation of T lymphocytes proliferation was observed with the peracetic acid treatment group. In conclusion, the disinfection strategy used can modify the immune system in fish at the level of T lymphocyte proliferation but was effective to remove the effects on phagocytosis activity.
Disinfection of swine wastewater using chlorine, ultraviolet light and ozone.
Macauley, John J; Qiang, Zhimin; Adams, Craig D; Surampalli, Rao; Mormile, Melanie R
2006-06-01
Veterinary antibiotics are widely used at concentrated animal feeding operations (CAFOs) to prevent disease and promote growth of livestock. However, the majority of antibiotics are excreted from animals in urine, feces, and manure. Consequently, the lagoons used to store these wastes can act as reservoirs of antibiotics and antibiotic-resistant bacteria. There is currently no regulation or control of these systems to prevent the spread of these bacteria and their genes for antibiotic resistance into other environments. This study was conducted to determine the disinfection potential of chlorine, ultraviolet light and ozone against swine lagoon bacteria. Results indicate that a chlorine dose of 30 mg/L could achieve a 2.2-3.4 log bacteria reduction in lagoon samples. However, increasing the dose of chlorine did not significantly enhance the disinfection activity due to the presence of chlorine-resistant bacteria. The chlorine resistant bacteria were identified to be closely related to Bacillus subtilis and Bacillus licheniformis. A significant percentage of lagoon bacteria were not susceptible to the four selected antibiotics: chlortetracycline, lincomycin, sulfamethazine and tetracycline (TET). However, the presence of both chlorine and TET could inactivate all bacteria in one lagoon sample. The disinfection potential of UV irradiation and ozone was also examined. Ultraviolet light was an effective bacterial disinfectant, but was unlikely to be economically viable due to its high energy requirements. At an ozone dose of 100 mg/L, the bacteria inactivation efficiency could reach 3.3-3.9 log.
Dos Santos, Andreia Betina Kreuser; Claro, Elis Marina Turini; Montagnolli, Renato Nallin; Cruz, Jaqueline Matos; Lopes, Paulo Renato Matos; Bidoia, Ederio Dino
2017-12-15
Electrochemically assisted photocatalysis (by electronic drainage) is a highly promising method for disinfection of water. In this research, the efficiency of photolytic oxidation using UV-A radiation and electrochemically assisted photocatalysis (with electric potential of 1.5 V) was studied by using electrodes prepared by thermal treatment and doped with silver, for inactivation of Escherichia coli and Staphylococcus aureus. The Chick-Watson microorganism inactivation model was applied and the electrical energy consumption of the process was calculated. It was observed no significant inactivation of microorganisms when UV-A light or electric potential were applied separately. However, the electrochemically assisted photocatalytic process, with Ag-doped electrode completely inactivated the microbial population after 10 (E. coli) and 60 min (S. aureus). The best performing non-doped electrodes achieved 52.74% (E. coli) and 44.09% (S. aureus) inactivation rates after 60 min. Thus, electrochemically assisted photocatalytic activity was not only effective for the inactivation of microorganisms, but also notably low on electrical energy consumption during the treatment due to small current and low electric potential applied. Copyright © 2017 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karunakaran, C., E-mail: karunakaranc@rediffmail.com; Abiramasundari, G.; Gomathisankar, P.
2011-10-15
Highlights: {yields} ZnO-TiO{sub 2} nanocomposite, obtained by modified ammonia-evaporation-induced synthetic method, absorbs visible light. {yields} ZnO-TiO{sub 2} nanoparticles catalyze bacteria disinfection and cyanide detoxification under sunlight. {yields} ZnO-TiO{sub 2} nanocomposite is selective in photocatalysis. -- Abstract: ZnO-TiO{sub 2} nanocomposite was prepared by modified ammonia-evaporation-induced synthetic method. It was characterized by powder X-ray diffraction, transmission electron microscopy, selected area electron diffraction, and energy dispersive X-ray, UV-visible diffuse reflectance, photoluminescence and electrochemical impedance spectroscopies. Incorporation of ZnO leads to visible light absorption, larger charge transfer resistance and lower capacitance. The nanocomposite effectively catalyzes the inactivation of E. coli under visible light. Further,more » the prepared nanocomposite displays selective photocatalysis. While its photocatalytic efficiency to detoxify cyanide with visible light is higher than that of TiO{sub 2} P25, its efficiency to degrade methylene blue, sunset yellow and rhodamine B dyes under UV-A light is less than that of TiO{sub 2} P25.« less
Mayer, Brooke K; Daugherty, Erin; Abbaszadegan, Morteza
2015-02-01
Advanced oxidation processes (AOPs) are gaining traction as they offer mineralization potential rather than transferring contaminants between media. However, AOPs operated with limited energy and/or chemical inputs can exacerbate disinfection byproduct (DBP) formation, even as precursors such as dissolved organic carbon, UV254, and specific UV absorbance (SUVA) decrease. This study examined the relationship between DBP precursors and formation using TiO2 photocatalysis experiments, external AOP and non-AOP data, and predictive DBP models. The top-performing indicator, SUVA, generally correlated positively with trihalomethanes and haloacetic acids, but limited-energy photocatalysis yielded contrasting negative correlations. The accuracy of predicted DBP values from models based on bulk parameters was generally poor, regardless of use and extent of AOP treatment and type of source water. Though performance improved for scenarios bounded by conditions used in model development, only 0.5% of the model/dataset pairings satisfied all measured parameter boundary conditions, thereby introducing skepticism toward model usefulness. Study findings suggest that caution should be employed when using bulk indicators and/or models as a metric for AOP mitigation of DBP formation potential, particularly for limited-energy/chemical inputs. Copyright © 2014 Elsevier Ltd. All rights reserved.
Escudero, M E; Velázquez, L; Favier, G; de Guzmán, A M
2003-06-01
This study assessed the effectiveness of 200 and 500 ppm of chlorine and organic acids (0.5% lactic acid and 0.5% citric acid) in wash solutions, and UV radiation for reducing Escherichia coli O157:H7 and Yersinia enterocolitica on apples contaminated by two different methods. Residual levels of these pathogens after different treatments were compared. On dip inoculated apples, Y. enterocolitica reductions of 2.66 and 2.77 logs were obtained with 200 and 500 ppm chlorine combined with 0.5% lactic acid, respectively. The E. coli O157:H7 population decreased 3.35 log with 0.5% lactic acid wash solution, and 2.72 and 2.62 logs after 500 ppm chlorine and 500 ppm chlorine plus 0.5% lactic acid treatments, respectively. Similar reductions were obtained with UV radiation. On spot inoculated apples, significant (p < 0.05) decreases of 4.67 and 4.58 logs were observed in E. coli O157:H7 and Y. enterocolitica levels, respectively, after 500 ppm chlorine plus 0.5% lactic acid treatment as compared with the control. In sectioned apples, microorganisms infiltrated in inner core region and pulp were not significantly (p < 0.05) affected by disinfection treatments. No pathogens were detected in the natural microflora on apples. Reductions such as those obtained with 500 ppm chlorine plus 0.5% lactic acid solution were very proximal to the 5-log score required by FDA for apple disinfection.
Di Cesare, Andrea; Fontaneto, Diego; Doppelbauer, Julia; Corno, Gianluca
2016-09-20
Antibiotic resistance genes (ARGs) are increasingly appreciated to be important as micropollutants. Indirectly produced by human activities, they are released into the environment, as they are untargeted by conventional wastewater treatments. In order to understand the fate of ARGs and of other resistant forms (e.g., phenotypical adaptations) in urban wastewater treatment plants (WWTPs), we monitored three WWTPs with different disinfection processes (chlorine, peracetic acid (PAA), and ultraviolet light (UV)). We monitored WWTPs influx and pre- and postdisinfection effluent over 24 h, followed by incubation experiments lasting for 96 h. We measured bacterial abundance, size distribution and aggregational behavior, the proportion of intact (active) cells, and the abundances of four ARGs and of the mobile element integron1. While all the predisinfection treatments of all WWTPs removed the majority of bacteria and of associated ARGs, of the disinfection processes only PAA efficiently removed bacterial cells. However, the stress imposed by PAA selected for bacterial aggregates and, similarly to chlorine, stimulated the selection of ARGs during the incubation experiment. This suggests disinfections based on chemically aggressive destruction of bacterial cell structures can promote a residual microbial community that is more resistant to antibiotics and, given the altered aggregational behavior, to competitive stress in nature.
Extraordinary survival of nanobacteria under extreme conditions
NASA Astrophysics Data System (ADS)
Bjorklund, Michael; Ciftcioglu, Neva; Kajander, E. Olavi
1998-07-01
Nanobacteria show high resistance to gamma irradiation. To further examine their survival in extreme conditions several disinfecting and sterilizing chemicals as well as autoclaving, UV light, microwaves, heating and drying treatments were carried out. The effect of antibiotics used in cell culture were also evaluated. Two forms of nanobacteria were used in the tests: nanobacteria cultured in serum containing medium, and nanobacteria cultured in serum-free medium, the latter being more mineralized. Nanobacteria, having various amounts of apatite on their surfaces, were used to analyze the degree of protection given by the mineral. The chemicals tested included ethanol, glutaraldehyde, formalin, hypochlorite, hydrogen peroxide, hydrochloric acid, sodium hydroxide, detergents, and commercial disinfectants at concentrations generally used for disinfection. After chemical and physical treatments for various times, the nanobacteria were subcultered to detect their survival. The results show unique and wide resistance of nanobacteria to common agents used in disinfection. It can also be seen that the mineralization of the nanobacterial surface furthermore increases the resistance. Survival of nanobacteria is unique among living bacteria, but it can be compared with that observed in spores. Interestingly, nanobacteria have metabolic rate as slow as bacterial spores. A slow metabolic rate and protective structures, like mineral, biofilm and impermeable cell wall, can thus explain the observations made.
Abbey, Ashkan M.; Gregori, Ninel Z.; Surapaneni, Krishna; Miller, Darlene
2014-01-01
Purpose While manufacturers recommend cleaning ophthalmic lenses with detergent and water and then a specific disinfectant, disinfectants are rarely used in ophthalmic practices. The aim of this pilot study was to evaluate the efficacy of detergent and water versus bleach, a recommended disinfectant, to eliminate common ocular bacteria and viruses from ophthalmic lenses. Methods Three bacterial strains (Staphylococcus epidermidis, Corynebacterium straitum, and methicillin-resistant Staphylococcus aureus (MRSA) and two viral strains (adenovirus and herpes simplex virus (HSV) type-1) were individually inoculated to 20 gonioscopy and laser lenses. Lenses were washed with detergent and water and then disinfected with 10% bleach. All lenses were cultured after inoculation, after detergent and water, and after the bleach. Bacterial cultures in thioglycollate broth were observed for 3 weeks and viral cultures for 2 weeks. The presence of viruses was also detected by multiplex polymerase chain reaction (PCR). Results All 20 lenses inoculated with Staphylococcus epidermidis, Corynebacterium straitum, adenovirus, and HSV-1 showed growth after inoculation, but no growth after detergent/water and after the bleach. All lenses showed positive HSV and adenovirus PCR after inoculation and negative PCR after detergent/water and after bleach. All MRSA contaminated lenses showed growth after inoculation and no growth after detergent and water. However, one lens showed positive growth after bleach. Conclusions Cleaning with detergent and water appeared to effectively eliminate bacteria and viruses from the surface of contaminated ophthalmic lenses. Further studies are warranted to design practical disinfection protocols that minimize lens damage. PMID:24747806
NASA Astrophysics Data System (ADS)
Heredia-Munoz, Manuel Antonio
Water is perhaps the most important resource that sustains human life. According to the World Health Organization (WHO), almost two billion people do not have access to the required water that is needed to satisfy their daily needs and one billion do not have access to clean sources of water for consumption, most of them living in isolated and poor areas around the globe. Poor quality water increases the risk of cholera, typhoid fever and dysentery, and other water-borne illness making this problem a real crisis that humankind is facing. Several water disinfection technologies have been proposed as solutions for this problem. Solar water disinfection using TiO2 coated PET bottles was the alternative that is studied in this work. This technology does not only inactivate bacteria but also disintegrates organic chemicals that can be present in water. The objectives of this work address the optimization of the TiO 2 coated PET bottles technologies. The improvement on the bottle coating process, using two coats of 10% W/V of TiO2 in a solution of vinegar and sodium bicarbonate to form the TiO2 film, the use of a different indigo carmine (1.25 X 10-1mg/pill) concentration in the pill indicator of contamination, the increase of the disinfection rate through shaking the bottles, degradation under intermittent UV radiation and the effect of bottle size on photocatalytic water disinfection were among the most important findings. A new mathematical model that describes better photocatalytic water disinfection in TiO2 coated bottles and simulates water disinfection under different working conditions was another important achievement. These results can now be used to design a strategy for disseminating this technology in areas where it is required and, in that way, generate the greatest positive impact on the people needing safe drinking water.
Pham, Thanh-Dong; Lee, Byeong-Kyu
2014-08-15
Ag doped TiO2/glass fibers (Ag-TiO2/GF) were prepared and used for photocatalytic disinfection of Escherichia coli (E. coli) in an indoor air environment. The prepared photocatalysts were characterized using scanning electron microscope (SEM) for morphology, X-ray diffraction (XRD) for microstructure, UV-Visible diffuse reflectance spectra (DRS) for optical properties and X-ray photoelectron spectroscopy (XPS) to determine elemental state. The optimized weight fraction of TiO2 in the TiO2/glass fiber (TiO2/GF) was 3%. The silver content in Ag/TiO2 was altered from 1% to 10% to investigate the optimal ratio of Ag doped on the TiO2/GF for the photocatalytic disinfection of E. coli. Doped Ag enhanced the electron-hole separation as well as charge transfer efficiency between the valance band and the conduction band of TiO2. The generated electron-hole pairs reacted with water and molecular oxygen to form strong oxidative radicals, which participated in the oxidation of organic components of E. coli, resulting in bacterial death. The photocatalytic disinfection activity under visible light increased with the increase in silver content up to 7.5% and then decreased slightly with further increasing Ag content. Among the three humidity conditions used in this study (40±5%, 60±5%, 80±5%), the highest disinfection ratio of E. coli by the photocatalytic system was observed in the intermediate humidity level followed by the high humidity level. Using the 7.5% Ag-TiO2/GF and the intermediate level of humidity (60±5%), the highest disinfection ratio and disinfection capacity of E. coli were 93.53% and 26 (CFU/s cm(2)), respectively. Copyright © 2014 Elsevier Inc. All rights reserved.
Rott, Eduard; Kuch, Bertram; Lange, Claudia; Richter, Philipp; Minke, Ralf
2018-06-16
This work investigates the influence of ammonium ions and the organic load (chemical oxygen demand (COD)) on the UV/chlorine AOP regarding the maintenance of free available chlorine (FAC) and elimination of 16 emerging contaminants (ECs) from wastewater treatment plant effluent (WWTE) at pilot scale (UV chamber at 0.4 kW). COD inhibited the FAC maintenance in the UV chamber influent at a ratio of 0.16 mg FAC per mg COD ( k HOCl⁻COD = 182 M −1 s −1 ). An increase in ammonium ion concentration led to a stoichiometric decrease of the FAC concentration in the UV chamber influent. Especially in cold seasons due to insufficient nitrification, the ammonium ion concentration in WWTE can become so high that it becomes impossible to achieve sufficiently high FAC concentrations in the UV chamber influent. For all ECs, the elimination effect by the UV/combined Cl₂ AOP (UV/CC) was not significantly higher than that by sole UV treatment. Accordingly, the UV/chlorine AOP is very sensitive and loses its effectiveness drastically as soon as there is no FAC but only CC in the UV chamber influent. Therefore, within the electrical energy consumption range tested (0.13⁻1 kWh/m³), a stable EC elimination performance of the UV/chlorine AOP cannot be maintained throughout the year.
Use of solar radiation for continuous water disinfection in isolated areas.
Fabbricino, M; d'Antonio, L
2012-01-01
This study involved investigation of solar water disinfection in continuously working treatment plants with the aim of producing safe drinking water in isolated areas. Results were obtained from experimental work carried out on a pilot plant operating in different configurations. The use of a simple device to increase solar radiation intensity (solar concentrator) was tested, with results showing that it facilitated better performance. A comparison between transparent and black-painted glass reactors was also made, showing no difference between the two casings. Further, the effect of an increase in water temperature was analysed in detail. Temperature was found to play an important role in the disinfection process, even in cases of limited solar radiation intensities, although a synergistic effect of water heating and solar radiation for effective microbial inactivation was confirmed. Reactor design is also discussed, highlighting the importance of having a plug flow to avoid zones that do not contribute to the overall effectiveness of the process.
Klamerth, Nikolaus; Malato, Sixto; Agüera, Ana; Fernández-Alba, Amadeo; Mailhot, Gilles
2012-03-06
The goal of this paper was to develop a modified photo-Fenton treatment able to degrade micro pollutants in municipal wastewater treatment plant (MWTP) effluents at a neutral pH with minimal iron and H(2)O(2) concentrations. Complexation of Fe by ethylenediamine-N,N'-disuccinic acid (EDDS) leads to stabilization and solubilization of Fe at natural pH. Photo-Fenton experiments were performed in a pilot compound parabolic collector (CPC) solar plant. Samples were treated with solid phase extraction (SPE) and analyzed by HPLC-Qtrap-MS. The rapid degradation of contaminants within the first minutes of illumination and the low detrimental impact on degradation of bicarbonates present in the water suggested that radical species other than HO(•) are responsible for the efficiency of such photo-Fenton process. Disinfection of MWTP effluents by the same process showed promising results, although disinfection was not complete.
UV inactivation of pathogenic and indicator microorganisms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, J.C.; Ossoff, S.F.; Lobe, D.C.
1985-06-01
Survival was measured as a function of the dose of germicidal UV light for the bacteria Escherichia coli, Salmonella typhi, Shigella sonnei, Streptococcus faecalis, Staphylococcus aureus, and Bacillus subtilis spores, the enteric viruses poliovirus type 1 and simian rotavirus SA11, the cysts of the protozoan Acanthamoeba castellanii, as well as for total coliforms and standard plate count microorganisms from secondary effluent. The doses of UV light necessary for a 99.9% inactivation of the cultured vegetative bacteria, total coliforms, and standard plate count microorganisms were comparable. However, the viruses, the bacterial spores, and the amoebic cysts required about 3 to 4more » times, 9 times, and 15 times, respectively, the dose required for E. coli. These ratios covered a narrower relative dose range than that previously reported for chlorine disinfection of E. coli, viruses, spores, and cysts.« less
A novel strategy for water disinfection with a AgNPs/gelatin sponge filter.
Wei, Feng; Zhao, Xiaole; Li, Chao; Han, Xiaojun
2018-05-05
Disinfection of bacteria in water with sustainable and energy-efficient methods is still a great challenge. Herein, a novel gelatin sponge with embedded AgNPs is fabricated via freeze-drying using gelatin as the reducing agent to synthesize AgNPs in situ. UV-vis spectroscopy, HRTEM, XRD, and XPS characterization prove the formation of AgNPs with an average size of 8.55 ± 0.35 nm. TEM and SEM images confirm the even distribution of AgNPs throughout the AgNPs/gelatin sponges. The composite sponge has a low bulk density of 20 ± 3.5 mg/cm 3 and a pore size of 6.2 ± 1.5 μm. The AgNPs/gelatin sponges exhibit excellent antibacterial performance to E. coli in water, probably by destroying their cell membranes. The porous AgNPs/gelatin composite sponges are promising filter materials for water disinfection. The removal rate of AgNPs/gelatin composite sponges on E. coli reached almost 100%. Graphical abstract ᅟ.
Occurrence and fate of anti-inflammatory drugs in wastewater treatment plants in Japan.
Nakada, Norihide; Komori, Koya; Suzuki, Yutaka
2005-01-01
The fates of anti-inflammatory drugs (e.g., ibuprofen, naproxen, mefenamic acid and ketoprofen), which are frequently detected in the discharges of wastewater treatment plants (WWTPs) and river water in Japan, were clarified in two WWTPs. The concentrations of ibuprofen, naproxen, mefenamic acid and ketoprofen were 69-1080, 179-305, 143-1580 and 160-1060 ng/L in the influent, and N.D. (< 40 ng/L), 74-166, 72-265, 64-107 ng/L in the effluent, respectively. The concentrations of the anti-inflammatory drugs analyzed were almost equal to or lower than those reported in foreign countries. High removal efficiencies of the drugs, except ibuprofen, were observed in the WWTP that has longer hydraulic retention time than that of the other WWTP. For ibuprofen, high removal efficiencies were observed in both WWTPs (84 to 98%). Disinfection by chlorination was not effective to remove the drugs surveyed. On the other hand, the effective removal of ketoprofen by ultraviolet (UV) radiation for disinfection was demonstrated, although the disinfection by-products were not identified.
NASA Astrophysics Data System (ADS)
Hönes, Katharina; Stangl, Felix; Sift, Michael; Hessling, Martin
2015-07-01
The Ulm University of Applied Sciences is investigating a technique using visible optical radiation (405 nm and 460 nm) to inactivate health-hazardous bacteria in water. A conceivable application could be point-of-use disinfection implementations in developing countries for safe drinking water supply. Another possible application field could be to provide sterile water in medical institutions like hospitals or dental surgeries where contaminated pipework or long-term disuse often results in higher germ concentrations. Optical radiation for disinfection is presently mostly used in UV wavelength ranges but the possibility of bacterial inactivation with visible light was so far generally disregarded. One of the advantages of visible light is, that instead of mercury arc lamps, light emitting diodes could be used, which are commercially available and therefore cost-efficient concerning the visible light spectrum. Furthermore they inherit a considerable longer life span than UV-C LEDs and are non-hazardous in contrast to mercury arc lamps. Above all there are specific germs, like Bacillus subtilis, which show an inactivation resistance to UV-C wavelengths. Due to the totally different deactivation mechanism even higher disinfection rates are reached, compared to Escherichia coli as a standard laboratory germ. By 460 nm a reduction of three log-levels appeared with Bacillus subtilis and a half log-level with Escherichia coli both at a dose of about 300 J/cm². By the more efficient wavelength of 405 nm four and a half log-levels are reached with Bacillus subtilis and one and a half log-level with Escherichia coli also both at a dose of about 300 J/cm². In addition the employed optical setup, which delivered a homogeneous illumination and skirts the need of a stirring technique to compensate irregularities, was an important improvement compared to previous published setups. Evaluated by optical simulation in ZEMAX® the designed optical element provided proven homogeneity distributions with maximum variation of ± 10 %.
NASA Astrophysics Data System (ADS)
Rodrigues, D.; Teixeira, P.; Tavares, C. J.; Azeredo, J.
2013-04-01
Improvement of food safety is a very important issue, and is on the basis of production and application of new/modified food contact surfaces. Titanium dioxide (TiO2) and, more recently, nitrogen-doped titanium dioxide (N-TiO2) coatings are among the possible forms to enhance food contact surfaces performance in terms of higher hygiene and easier sanitation. In this context, the present work aimed at evaluating the bactericidal activity of an N-TiO2 coating on glass and stainless steel under two different sources of visible light - fluorescent and incandescent - and ultraviolet (UV) irradiation. Listeria monocytogenes was chosen as representative of major foodborne pathogens and its survival was tested on N-TiO2 coated coupons. In terms of survival percentage, good results were obtained after exposure of coated surfaces to all light types since, apart from the value obtained after exposing glass to fluorescent light (56.3%), survival rates were always below 50%. However, no effective disinfection was obtained, given that for a disinfectant or sanitizing agent to be claimed as effective it needs to be able to promote at least a 3-log reduction of the microbial load, which was not observed for any of the experimental conditions assessed. Even so, UV irradiation was the most successful on eliminating cells on coated surfaces, since the amount of bacteria was reduced to 1.49 × 106 CFU/ml on glass and 2.37 × 107 on stainless steel. In contrast, both visible light sources had only slightly decreased the amount of viable cells, which remained in the range of 8 log CFU/ml. Hence, although some bactericidal effect was accomplished under visible light, UV was the most effective light source on promoting photocatalytic reactions on N-TiO2 coated coupons and none of the experimental conditions have reached a satisfactory disinfection level. Thus, this surface coating needs further research and improvement in order to become truly effective against foodborne pathogens and, ultimately, become a useful tool towards food safety in general.
Inactivation of indigenous coliform bacteria in unfiltered surface water by ultraviolet light.
Cantwell, Raymond E; Hofmann, Ron
2008-05-01
This study examined the potential for naturally occurring particles to protect indigenous coliform from ultraviolet (UV) disinfection in four surface waters. Tailing in the UV dose-response curve of the bacteria was observed in 3 of the 4 water samples after 1.3-2.6-log of log-linear inactivation, implying particle-related protection. The impact of particles was confirmed by comparing coliform UV inactivation data for parallel filtered (11 microm pore-size nylon filters) and unfiltered surface water. In samples from the Grand River (UVT: 65%/cm; 5.4 nephelometric turbidity units (NTU)) and the Rideau Canal (UVT: 60%/cm; 0.84 NTU), a limit of approximately 2.5 log inactivation was achieved in the unfiltered samples for a UV dose of 20 mJ/cm2 while both the filtered samples exhibited >3.4-log inactivation of indigenous coliform bacteria. The results suggest that particles as small as 11 microm, naturally found in surface water with low turbidity (<3NTU), are able to harbor indigenous coliform bacteria and offer protection from low-pressure UV light.
Brindha, M.; Kumaran, N. Kurunji; Rajasigamani, K.
2014-01-01
Aim: The aim of this study is to evaluate, the influence of four types of sterilization/disinfection procedures (autoclave, hot air oven, glutaraldehyde, and ultraviolet [UV] light) on the tensile strength and surface topography of three orthodontic wires (stainless steel (SS), titanium - molybdenum alloy [TMA], and cobalt chromium (CoCr)). Materials and Methods: Sample comprised of three types of 8 inches straight length segments of orthodontic wires. They were divided into three groups according to wire composition comprising of 50 samples each. Totally 50 samples of each group were then equally divided into five subgroups according to sterilization method. After sterilization and disinfection of the experimental group, surface topography was examined with scanning electron microscope (SEM) and tensile strength was tested using universal testing machine. Result: The results of this study show that the mean ultimate tensile strength (UTS) of SS wire after four sterilization procedures were similar to the control group (1845.815 ± 142.29 MPa). The mean UTS of TMA wire increases after four sterilization procedures when compared with the control group (874.107 ± 275.939 MPa). The mean UTS of CoCr wire remains same after UV light disinfection, but increases after other three sterilization procedures when compared with the control group (1449.759 ± 156.586 MPa). SEM photographs of the present study shows gross increase in pitting roughness of the surface topography of all the three types of wires after four types of sterilization. Conclusion: Orthodontists who want to offer maximum safety for their patients can sterilize orthodontic wires before placement, as it does not deteriorate the tensile strength and surface roughness of the alloys. PMID:25210383
Brindha, M; Kumaran, N Kurunji; Rajasigamani, K
2014-07-01
The aim of this study is to evaluate, the influence of four types of sterilization/disinfection procedures (autoclave, hot air oven, glutaraldehyde, and ultraviolet [UV] light) on the tensile strength and surface topography of three orthodontic wires (stainless steel (SS), titanium - molybdenum alloy [TMA], and cobalt chromium (CoCr)). Sample comprised of three types of 8 inches straight length segments of orthodontic wires. They were divided into three groups according to wire composition comprising of 50 samples each. Totally 50 samples of each group were then equally divided into five subgroups according to sterilization method. After sterilization and disinfection of the experimental group, surface topography was examined with scanning electron microscope (SEM) and tensile strength was tested using universal testing machine. The results of this study show that the mean ultimate tensile strength (UTS) of SS wire after four sterilization procedures were similar to the control group (1845.815 ± 142.29 MPa). The mean UTS of TMA wire increases after four sterilization procedures when compared with the control group (874.107 ± 275.939 MPa). The mean UTS of CoCr wire remains same after UV light disinfection, but increases after other three sterilization procedures when compared with the control group (1449.759 ± 156.586 MPa). SEM photographs of the present study shows gross increase in pitting roughness of the surface topography of all the three types of wires after four types of sterilization. Orthodontists who want to offer maximum safety for their patients can sterilize orthodontic wires before placement, as it does not deteriorate the tensile strength and surface roughness of the alloys.
Nasser, Abidelfatah M; Benisti, Neta-Lee; Ofer, Naomi; Hovers, Sivan; Nitzan, Yeshayahu
2017-01-28
Advanced wastewater treatment processes are applied to prevent the environmental dissemination of pathogenic microorganisms. Giardia lamblia causes a severe disease called giardiasis, and is highly prevalent in untreated wastewater worldwide. Monitoring the microbial quality of wastewater effluents is usually based on testing for the levels of indicator microorganisms in the effluents. This study was conducted to compare the suitability of fecal coliforms, F+ coliphages and sulfide reducing clostridia (SRC) as indicators for the reduction of Giardia cysts in two full-scale wastewater treatment plants. The treatment process consists of activated sludge, coagulation, high rate filtration and either chlorine or UV disinfection. The results of the study demonstrated that Giardia cysts are highly prevalent in raw wastewater at an average concentration of 3600 cysts/L. Fecal coliforms, F+ coliphages and SRC were also detected at high concentrations in raw wastewater. Giardia cysts were efficiently removed (3.6 log 10 ) by the treatment train. The greatest reduction was observed for fecal coliforms (9.6 log 10 ) whereas the least reduction was observed for F+ coliphages (2.1 log 10 ) following chlorine disinfection. Similar reduction was observed for SRC by filtration and disinfection by either UV (3.6 log 10 ) or chlorine (3.3 log 10 ). Since F+ coliphage and SRC were found to be more resistant than fecal coliforms for the tertiary treatment processes, they may prove to be more suitable as indicators for Giardia. The results of this study demonstrated that advanced wastewater treatment may prove efficient for the removal of Giardia cysts and may prevent its transmission when treated effluents are applied for crop irrigation or streams restoration.
Evaluation of the Solar Water Disinfection Method Using an Ultraviolet Measurement Device
NASA Astrophysics Data System (ADS)
Leung, H.
2015-12-01
Drinking water security is a growing problem for the population of planet Earth. According to WHO, more than 750 million people on our planet lack access to safe drinking water, resulting in approximately 502,000 diarrhoea deaths in 2012. In order to solve this problem, the Swiss water research institute, Eawag, has developed a method of solar water disinfection, called, "SODIS" The theory of SODIS is simple to understand: a clear plastic bottle filled with water is placed under full sunlight for at least 6 hours. The ultraviolet radiation kills the pathogens in the water, making the originally contaminated water safe for drinking. In order to improve this method, Helioz, an Austrian social enterprise, has created the WADI, a UV measurement device which determines when water is safe for drinking using the SODIS method. When using the WADI, the device should be placed under the sun and surrounded with bottles of water that need to be decontaminated. There is a UV sensor on the WADI, and since the bottles of water and the WADI will have equal exposure to sunlight, the WADI will be able to measure the impact of the sunlight on the contaminated water. This experiment tests the accuracy of the WADI device regarding the time interval needed for contaminated water to be disinfected. The experiment involves using the SODIS method to purify bottles of water contaminated with controlled samples of E. coli. Samples of the water are taken at different time intervals, and the E. coli levels are determined by growing the bacteria from the water samples on agar plates. Ultimately, this helps determine when the water is safe for drinking, and are compared against the WADI's measurements to test the reliability of the device.
James, Ray
2009-12-01
Chlorine-based products are widely used in the water supply industry, and the potential for adverse effects in the haemodialysis setting is well documented. To date, the most commonly used method of chlorine removal has been granular activated carbon filters. An increasingly popular method of dechlorination is the use of high intensity, broad-spectrum UV systems to reduce both free chlorine and combined chlorine compounds (chloramines) into easily removed by-products. UV radiation has been successfully used in the pharmaceutical and food industries to destroy free chlorine and/or chloramines present in water, and kill all known spoilage microorganisms including bacteria, viruses, yeasts and moulds (and their spores). This nonchemical method can offer significant advantages and benefits compared to conventional dechlorination technologies currently employed in dialysis water systems. Whilst UV treatment at 254 nm wavelength has been routinely used for disinfection purposes in dialysis water systems, this paper considers whether UV radiation can be used as an alternative to more traditional methods of chlorine removal.
Wang, Lu; Ji, Yuefei; Lu, Junhe; Kong, Deyang; Yin, Xiaoming; Zhou, Quansuo
2017-10-01
The objective of this research was to compare the transformation of Br - and formation of brominated byproducts in UV/persulfate (PS) and UV/H 2 O 2 processes. It was revealed that Br - was efficiently transformed to free bromine which reacted with humic acid (HA) or dihydroxybenzoic acid resulting in the formation of brominated byproducts such as bromoacetic acids (BAAs) in UV/PS system. In contrast, no free bromine and brominated byproducts could be detected in UV/H 2 O 2 system, although the oxidization of Br - was evident. We presumed that the oxidation of Br - by hydroxyl radicals led to the formation of bromine radicals. However, the bromine radical species could be immediately reduced back to Br - by H 2 O 2 before coupling to each other to form free bromine, which explains the undetection of free bromine and BAAs in UV/H 2 O 2 . In addition to free bromine, we found that the phenolic functionalities in HA molecules, which served as the principal reactive sites for free chlorine attack, could be in situ generated when HA was exposed to free radicals. This study demonstrates that UV/H 2 O 2 is more suitable than UV/PS for the treatment of environmental matrices containing Br - . Graphical abstract Graphical abstract.
Expósito, A J; Patterson, D A; Monteagudo, J M; Durán, A
2017-01-01
The photo-Fenton degradation of carbamazepine (CBZ) assisted with ultrasound radiation (US/UV/H 2 O 2 /Fe) was tested in a lab thin film reactor allowing high TOC removals (89% in 35min). The synergism between the UV process and the sonolytic one was quantified as 55.2%. To test the applicability of this reactor for industrial purposes, the sono-photo-degradation of CBZ was also tested in a thin film pilot plant reactor and compared with a 28L UV-C conventional pilot plant and with a solar Collector Parabolic Compound (CPC). At a pilot plant scale, a US/UV/H 2 O 2 /Fe process reaching 60% of mineralization would cost 2.1 and 3.8€/m 3 for the conventional and thin film plant respectively. The use of ultrasound (US) produces an extra generation of hydroxyl radicals, thus increasing the mineralization rate. In the solar process, electric consumption accounts for a maximum of 33% of total costs. Thus, for a TOC removal of 80%, the cost of this treatment is about 1.36€/m 3 . However, the efficiency of the solar installation decreases in cloudy days and cannot be used during night, so that a limited flow rate can be treated. Copyright © 2016 Elsevier B.V. All rights reserved.
Efficient water disinfection with Ag2WO4-doped mesoporous g-C3N4 under visible light.
Li, Yi; Li, Yanan; Ma, Shuanglong; Wang, Pengfei; Hou, Qianlei; Han, Jingjing; Zhan, Sihui
2017-09-15
Ag 2 WO 4 /g-C 3 N 4 composite photocatalyst was synthesized by polymerization of thiourea and ammonia chloride combined with the deposition-precipitation method, which was applied as an efficient visible-light driven photocatalyst for inactivating Escherichia coli (E. coli). The physicochemical properties of these photocatalysts were systematically characterized by various techniques such as SEM, TEM, XRD, FT-IR, BET, UV-vis DRS and PL. The synthesized photocatalysts exhibited outstandingly enhanced photocatalytic disinfection efficiency compared with that of pure g-C 3 N 4 and Ag 2 WO 4 under visible light. Furthermore, the optimal mass ratio of the Ag 2 WO 4 to g-C 3 N 4 was 5wt%, and a number of live bacteria could be completely inactivated with Ag 2 WO 4 (5%)/g-C 3 N 4 (100μg/mL) after 90min under visible light irradiation. The high disinfection efficiency is due to the synergetic effect between g-C 3 N 4 and Ag 2 WO 4 , including a good distribution of Ag 2 WO 4 particles on the surface of g-C 3 N 4 and an improved separation rate of photogenerated electron-hole pairs. The enhanced disinfection mechanism was also investigated using photogenerated current densities and electrochemical impedance spectroscopy (EIS). Considering the bulk availability and excellent disinfection activity of Ag 2 WO 4 /g-C 3 N 4 composite, it is a promising solar-driven photocatalyst for cleaning the microbial contaminated water. Copyright © 2017 Elsevier B.V. All rights reserved.
Wenhai, Chu; Tengfei, Chu; Erdeng, Du; Deng, Yang; Yingqing, Guo; Naiyun, Gao
2016-02-01
Ultraviolet/persulfate (UV/PS) has been widely used to generate sulfate radicals for degradation of water organic pollutants in previous studies. However, its impacts on disinfection byproduct formation during post-chlorination of degraded compounds is unclear. The objective of this study was to evaluate the impacts of UV irradiation, PS oxidation, and the combined UV/PS advanced oxidation process (AOP) pre-treatments on halomethane formation during the following chlorination of chloramphenicol (CAP), a model antibiotic commonly found in wastewater-impacted water. Results showed that CAP could be transformed to more trichloromethane (TCM) than monochloromethane (MCM) and dichloromethane (DCM) in the presence of excess chlorine. UV photolysis, PS oxidation and UV/PS AOP all directly decomposed CAP to produce halomethanes (HMs) before post-chlorination. Moreover, UV and UV/PS pre-treatments both enhanced the formation of all the HMs in the subsequent chlorination. PS pre-oxidation decreased the TCM formation during post-chlorination, but increased the yields of MCM, DCM and total HMs. UV pre-irradiation significantly increased the bromide utilization of HMs, whereas UV/PS pre-oxidation decreased the bromine incorporation and utilization of HMs from the chlorination of CAP in a low-bromide water. UV irradiation, PS oxidation, and UV/PS AOP can inactivate pathogens and degrade organic pollutants, but this benefit should be weighed against a potential risk of the increased halomethane formation from degraded organic pollutants with and without post-chlorination. Copyright © 2015 Elsevier Inc. All rights reserved.
Energy-efficient drinking water disinfection for greenhouse gas mitigation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gadgil, A.J.; Greene, D.M.; Rosenfeld, A.
Anecdotal evidence suggests that approximately one billion people worldwide use cookstoves to boil their drinking water. About half of this population is in China. Some populations (e.g. Jakarta) spend 1% of their GDP on boiling drinking water. Impoverished and/or ignorant populations not yet boiling their drinking water will do so when they can both afford it and understand the risks of unsafe drinking water. A recently developed water disinfection technology (UV Waterworks) can produce safe drinking water while earning tradable carbon credits (or credit as a clean development mechanism) when implemented as part of national energy, health, and carbon emissionsmore » trading policy, UV Waterworks uses approximately 6,000 times less energy than boiling over a biomass cookstove. Each unit that replaces boiling may save up to 175 or 300 tons/year of carbon-equivalent GHG emissions, depending on if it replaces sustainably harvested biomass (SHB) or non-SHB. For the approximately 500M Chinese boiling their drinking water over biomass (assumed SHB), this suggests a technical potential (that is, potential under the limiting case of 100% market adoption) of saving 87M tons/year of carbon-equivalent non-CO{sub 2} GHG emissions. The energy savings and corresponding emissions reductions will vary with cookstove fuels and stove efficiency: non-SHB and kerosene represent the most and least GHG-producing cookstove fuels, respectively, among those readily available to the populations of interest. The authors bracket the global technical potential for carbon emission reductions resulting from implementation of UV Waterworks, and estimate the value of tradable carbon credits earned from these reductions.« less
An image-guided tool to prevent hospital acquired infections
NASA Astrophysics Data System (ADS)
Nagy, Melinda; Szilágyi, László; Lehotsky, Ákos; Haidegger, Tamás; Benyó, Balázs
2011-03-01
Hospital Acquired Infections (HAI) represent the fourth leading cause of death in the United States, and claims hundreds of thousands of lives annually in the rest of the world. This paper presents a novel low-cost mobile device|called Stery-Hand|that helps to avoid HAI by improving hand hygiene control through providing an objective evaluation of the quality of hand washing. The use of the system is intuitive: having performed hand washing with a soap mixed with UV re ective powder, the skin appears brighter in UV illumination on the disinfected surfaces. Washed hands are inserted into the Stery-Hand box, where a digital image is taken under UV lighting. Automated image processing algorithms are employed in three steps to evaluate the quality of hand washing. First, the contour of the hand is extracted in order to distinguish the hand from the background. Next, a semi-supervised clustering algorithm classies the pixels of the hand into three groups, corresponding to clean, partially clean and dirty areas. The clustering algorithm is derived from the histogram-based quick fuzzy c-means approach, using a priori information extracted from reference images, evaluated by experts. Finally, the identied areas are adjusted to suppress shading eects, and quantied in order to give a verdict on hand disinfection quality. The proposed methodology was validated through tests using hundreds of images recorded in our laboratory. The proposed system was found robust and accurate, producing correct estimation for over 98% of the test cases. Stery-Hand may be employed in general practice, and it may also serve educational purposes.
Sorlini, Sabrina; Biasibetti, Michela; Collivignarelli, Maria Cristina; Crotti, Barbara Marianna
2015-01-01
Chlorine dioxide is one of the most widely employed chemicals in the disinfection process of a drinking water treatment plant (DWTP). The aim of this work was to evaluate the influence of the adsorption process with granular activated carbon (GAC) on the chlorine dioxide consumption in final oxidation/disinfection. A first series of tests was performed at the laboratory scale employing water samples collected at the outlet of the DWTP sand filter of Cremona (Italy). The adsorption process in batch conditions with seven different types of GAC was studied. A second series of tests was performed on water samples collected at the outlet of four GAC columns installed at the outlet of the DWTP sand filter. The results showed that the best chlorine dioxide demand (ClO2-D) reduction yields are equal to 60-80% and are achieved in the first 30 min after ClO2 addition, during the first 16 days of the column operation using a mineral, coal-based, mesoporous GAC. Therefore, this carbon removes organic compounds that are more rapidly reactive with ClO2. Moreover, a good correlation was found between the ClO2-D and UV absorbance at wavelength 254 nm using mineral carbons; therefore, the use of a mineral mesoporous GAC is an effective solution to control the high ClO2-D in the disinfection stage of a DWTP.
NASA Astrophysics Data System (ADS)
Riyanto; Agustiningsih, W. A.
2018-04-01
Disinfection of coliform and E. Coli in water has been performed by electrolysis using carbon electrodes. Carbon electrodes were used as an anode and cathode with a purity of 98.31% based on SEM-EDS analysis. This study was conducted using electrolysis powered by electric field using carbon electrode as the anode and cathode. Electrolysis method was carried out using variations of time (30, 60, 90, 120 minutes at a voltage of 5 V) and voltage (5, 10, 15, 20 V for 30 minutes) to determine the effect of the disinfection of the bacteria. The results showed the number of coliform and E. coli in water before and after electrolysis was 190 and 22 MPN/100 mL, respectively. The standards quality of drinking water No. 492/Menkes/Per/IV/2010 requires the zero content of coliform and E. Coli. Electrolysis with the variation of time and potential can reduce the number of coliforms and E. Coli but was not in accordance with the standards. The effect of hydrogen peroxide (H2O2) to the electrochemical disinfection was determined using UV-Vis spectrophotometer. The levels of H2O2 formed increased as soon after the duration of electrolysis voltage but was not a significant influence to the mortality of coliform and E.coli.
Disinfection of Airborne Organisms by Ultraviolet-C Radiation and Sunlight
2012-07-01
organisms deposited on surfaces, suspended in water , and contaminating food, all of which have been discussed elsewhere (Block, 2001). In contrast, the... water . Therefore, the primary means for organism inactivation in aerosols is ultraviolet (UV) radiation. Radiation from the sunlight is used as a...cortex is essential for reduction of the water content in the spore core and formation of a dormant spore. The cortex is degraded in spore
Treatment of Simulated Shipboard Gray Water in a Lab-Scale Membrane Bioreactor
2005-12-01
bioreactors ( MBRs ). MBRs with submerged membrane modules are considered a promising wastewater technology for use aboard ships since significant treatment...system, which consisted of an equalization tank, an MBR with submerged hollow fiber membranes, and a UV disinfection system. The reactor was...1999) optimized removal of TN in an intermittently aerated MBR with submerged hollow fiber membranes. They achieved an average TN removal of 83
Disinfection byproduct formation in drinking water sources: A case study of Yuqiao reservoir.
Zhai, Hongyan; He, Xizhen; Zhang, Yan; Du, Tingting; Adeleye, Adeyemi S; Li, Yao
2017-08-01
This study investigated the potential formation of disinfection byproducts (DBPs) during chlorination and chloramination of 20 water samples collected from different points of Yuqiao reservoir in Tianjin, China. The concentrations of dissolved organic matter and ammonia decreased downstream the reservoir, while the specific UV absorbance (SUVA: the ratio of UV 254 to dissolved organic carbon) increased [from 0.67 L/(mg*m) upstream to 3.58 L/(mg*m) downstream]. The raw water quality played an important role in the formation of DBPs. During chlorination, haloacetic acids (HAAs) were the major DBPs formed in most of the water samples, followed by trihalomethanes (THMs). CHCl 3 and CHCl 2 Br were the major THM species, while trichloroacetic acid (TCAA) and dichloroacetic acid (DCAA) were the major HAA species. Chloramination, on the other hand, generally resulted in lower concentrations of THMs (CHCl 3 ), HAAs (TCAA and DCAA), and haloacetonitriles (HANs). All the species of DBPs formed had positive correlations with the SUVA values, and HANs had the highest one (R 2 = 0.8). The correlation coefficients between the analogous DBP yields and the SUVA values in chlorinated samples were close to those in chloraminated samples. Copyright © 2017 Elsevier Ltd. All rights reserved.
Hijnen, W A M; Beerendonk, E F; Medema, G J
2006-01-01
UV disinfection technology is of growing interest in the water industry since it was demonstrated that UV radiation is very effective against (oo)cysts of Cryptosporidium and Giardia, two pathogenic micro-organisms of major importance for the safety of drinking water. Quantitative Microbial Risk Assessment, the new concept for microbial safety of drinking water and wastewater, requires quantitative data of the inactivation or removal of pathogenic micro-organisms by water treatment processes. The objective of this study was to review the literature on UV disinfection and extract quantitative information about the relation between the inactivation of micro-organisms and the applied UV fluence. The quality of the available studies was evaluated and only high-quality studies were incorporated in the analysis of the inactivation kinetics. The results show that UV is effective against all waterborne pathogens. The inactivation of micro-organisms by UV could be described with first-order kinetics using fluence-inactivation data from laboratory studies in collimated beam tests. No inactivation at low fluences (offset) and/or no further increase of inactivation at higher fluences (tailing) was observed for some micro-organisms. Where observed, these were included in the description of the inactivation kinetics, even though the cause of tailing is still a matter of debate. The parameters that were used to describe inactivation are the inactivation rate constant k (cm(2)/mJ), the maximum inactivation demonstrated and (only for bacterial spores and Acanthamoeba) the offset value. These parameters were the basis for the calculation of the microbial inactivation credit (MIC="log-credits") that can be assigned to a certain UV fluence. The most UV-resistant organisms are viruses, specifically Adenoviruses, and bacterial spores. The protozoon Acanthamoeba is also highly UV resistant. Bacteria and (oo)cysts of Cryptosporidium and Giardia are more susceptible with a fluence requirement of <20 mJ/cm(2) for an MIC of 3 log. Several studies have reported an increased UV resistance of environmental bacteria and bacterial spores, compared to lab-grown strains. This means that higher UV fluences are required to obtain the same level of inactivation. Hence, for bacteria and spores, a correction factor of 2 and 4 was included in the MIC calculation, respectively, whereas some wastewater studies suggest that a correction of a factor of 7 is needed under these conditions. For phages and viruses this phenomenon appears to be of little significance and for protozoan (oo)cysts this aspect needs further investigation. Correction of the required fluence for DNA repair is considered unnecessary under the conditions of drinking water practice (no photo-repair, dark repair insignificant, esp. at higher (60 mJ/cm(2)) fluences) and probably also wastewater practice (photo-repair limited by light absorption). To enable accurate assessment of the effective fluence in continuous flow UV systems in water treatment practice, biodosimetry is still essential, although the use of computational fluid dynamics (CFD) improves the description of reactor hydraulics and fluence distribution. For UV systems that are primarily dedicated to inactivate the more sensitive pathogens (Cryptosporidium, Giardia, pathogenic bacteria), additional model organisms are needed to serve as biodosimeter.
NASA Astrophysics Data System (ADS)
Cowan, Troy E.
2018-02-01
Healthcare Acquired Infections (HAIs) pose a significant health risk to our nation, especially to those most in need of healthcare. One in every 25 people admitted to a hospital will be infected by one or more HAIs. Significant reductions in HAI risks can be advanced through innovative technologies, such as UV antimicrobial disinfecting devices. Development of such technologies, along with the associated Behavioral, Chemical and Technological protocols to combat infectious HAIs is a worthwhile pursuit for the public good. A significant good will be accomplished by engaging optical scientists and engineers as well as healthcare professionals in opportunities to advance light-driven antimicrobial devices to halt infections. Fundamental change can be effected through a path of advancing standards and methods including optical measurements, and testing the efficacy of UV light antimicrobial devices and related technologies.
Solar treatment of cork boiling and bleaching wastewaters in a pilot plant.
Vilar, Vítor J P; Maldonado, Manuel I; Oller, I; Malato, Sixto; Boaventura, Rui A R
2009-09-01
This paper reports on cork boiling and bleaching wastewaters treatment by solar photocatalytic processes, TiO(2)/UV and Fe(2+)/H(2)O(2)/UV (TiO(2)-only for bleaching wastewater), in a pilot plant with compound parabolic collectors. The photo-Fenton reaction (k=0.12L/kJ(UV), r(0)=59.4 mg/kJ(UV)) is much more efficient that TiO(2) photocatalysis and TiO(2)+S(2)O(8)(2-) (k=0.0024 L/kJ(UV), r(0)=1.36 mg/kJ(UV)), leading to 94% mineralization of the bleaching wastewater after 31.5 kJ(UV)/L, consuming 77.1mM of H(2)O(2) (3.0 mmol/kJ(UV)) and using 20 mg/L of iron. For the cork boiling wastewater, after a slow initial reaction rate, the DOC degradation curve shows a first-order kinetics behaviour (k=0.015 L/kJ(UV), r(0)=20.8 mg/kJ(UV)) until 173 kJ(UV)/L ( approximately 300 mgC/L). According to the average oxidation state (AOS), toxicity profiles, respirometry and kinetic results obtained in two solar CPCs plants, the optimal energy dose estimated for phototreatment to reach a biodegradable effluent is 15 kJ(UV)/L and 114 kJ(UV)/L, consuming 33 mM and 151 mM of H(2)OT:/PGN/ELSEVIER/WR/web/00007490/(2), achieving almost 49% and 48% mineralization of the wastewaters, respectively for the cork bleaching and boiling wastewaters.
Dong, Huiyu; Qiang, Zhimin; Hu, Jun; Qu, Jiuhui
2017-09-15
Ultraviolet (UV)/chlorine process is considered as an emerging advanced oxidation process for the degradation of micropollutants. This study investigated the degradation of chloramphenicol (CAP) and formation of disinfection by-products (DBPs) during the UV/chlorine treatment. It was found that CAP degradation was enhanced by combined UV/chlorine treatment compared to that of UV and chlorination treatment alone. The pseudo-first-order rate constant of the UV/chlorine process at pH 7.0 reached 0.016 s -1 , which was 10.0 and 2.0 folds that observed from UV and chlorination alone, respectively. The enhancement can be attributed to the formation of diverse radicals (HO and reactive chlorine species (RCSs)), and the contribution of RCSs maintained more stable than that of HO at pH 5.5-8.5. Meanwhile, enhanced DBPs formation during the UV/chlorine treatment was observed. Both the simultaneous formation and 24-h halonitromethanes formation potential (HNMsFP) were positively correlated with the UV/chlorine treatment time. Although the simultaneous trichloronitromethane (TCNM) formation decreased with the prolonged UV irradiation, TCNM dominated the formation of HNMs after 24 h (>97.0%). According to structural analysis of transformation by-products, both the accelerated CAP degradation and enhanced HNMs formation steps were proposed. Overall, the formation of diverse radicals during the UV/chlorine treatment accelerated the degradation of CAP, while also enhanced the formation of DBPs simultaneously, indicating the need for DBPs evaluation before the application of combined UV/chlorine process. Copyright © 2017 Elsevier Ltd. All rights reserved.
Chevremont, A-C; Boudenne, J-L; Coulomb, B; Farnet, A-M
2013-04-15
Advanced oxidation processes based on UV radiations have been shown to be a promising wastewater disinfection technology. The UV-LED system involves innovative materials and could be an advantageous alternative to mercury-vapor lamps. The use of the UV-LED system results in good water quality meeting the legislative requirements relating to wastewater reuse for irrigation. The aim of this study was to investigate the impact of watering with UV-LED treated wastewaters (UV-LED WW) on soil parameters. Solid-state ¹³C NMR shows that watering with UV-LED WW do not change the chemical composition of soil organic matter compared to soil watered with potable water. Regarding microbiological parameters, laccase, cellulase, protease and urease activities increase in soils watered with UV-LED WW which means that organic matter brought by the effluent is actively degraded by soil microorganisms. The functional diversity of soil microorganisms is not affected by watering with UV-LED WW when it is altered by 4 and 8 months of watering with wastewater (WW). After 12 months, functional diversity is similar regardless of the water used for watering. The persistence of faecal indicator bacteria (coliform and enterococci) was also determined and watering with UV-LED WW does not increase their number nor their diversity unlike soils irrigated with activated sludge wastewater. The study of watering-soil microcosms with UV-LED WW indicates that this system seems to be a promising alternative to the UV-lamp-treated wastewaters. Copyright © 2013 Elsevier Ltd. All rights reserved.
Li, Wen-Tao; Jin, Jing; Li, Qiang; Wu, Chen-Fei; Lu, Hai; Zhou, Qing; Li, Ai-Min
2016-04-15
Online monitoring dissolved organic matter (DOM) is urgent for water treatment management. In this study, high performance size exclusion chromatography with multi-UV absorbance and multi-emission fluorescence scans were applied to spectrally characterize samples from 16 drinking water sources across Yangzi River and Huai River Watersheds. The UV absorbance indices at 254 nm and 280 nm referred to the same DOM components and concentration, and the 280 nm UV light could excite both protein-like and humic-like fluorescence. Hence a novel UV fluorescence sensor was developed out using only one UV280 light-emitting diode (LED) as light source. For all samples, enhanced coagulation was mainly effective for large molecular weight biopolymers; while anion exchange further substantially removed humic substances. During chlorination tests, UVA280 and UVA254 showed similar correlations with yields of disinfection byproducts (DBPs); the humic-like fluorescence obtained from LED sensors correlated well with both trihalomethanes and haloacetic acids yields, while the correlation between protein-like fluorescence and trihalomethanes was relatively poor. Anion exchange exhibited more reduction of DBPs yields as well as UV absorbance and fluorescence signals than enhanced coagulation. The results suggest that the LED UV fluorescence sensors are very promising for online monitoring DOM and predicting DBPs formation potential during water treatment. Copyright © 2016 Elsevier Ltd. All rights reserved.
Toor, Ramn; Mohseni, Madjid
2007-02-01
The presence of disinfection byproducts (DBPs) such as trihalomethanes (THMs) and haloacetic acids (HAAs) in drinking water is of great concern due to their adverse effects on human health. Emerging regulation limiting the concentration of DBPs in drinking water has increased demands for technologies and processes which reduce the formation of DBPs in drinking water. In this study, UV-H2O2 based advance oxidation process (AOP) was used to treat raw surface water. Experiments were conducted using low pressure mercury vapor UV lamps in collimated beam and flow-through annular photoreactors. The effect of UV fluence (0-3500 mJ cm(-2)) and hydrogen peroxide concentration (0-23 mg l(-1)) in reducing the concentration of THMs and HAAs was examined. The UV-H2O2 AOP was then coupled with a downstream biological activated carbon (BAC) treatment to assess the synergetic benefits of combining the two treatments. It was observed that UV-H2O2 AOP was only effective at reducing DBPs at UV fluences of more than 1000 mJ cm(-2) and initial H2O2 concentrations of about or greater than 23 mg l(-1). However, the combined AOP-BAC treatment showed significant reductions of 43%, 52%, and 59% relative to untreated raw water for DBPs, TOC, and UV254, respectively.
Low pressure ultraviolet studies for inactivation of Giardia muris cysts.
Hayes, S L; Rice, E W; Ware, M W; Schaefer, F W
2003-01-01
The research was initiated to confirm earlier ultraviolet (u.v.) light inactivation studies performed on Giardia cysts using excystation as the viability indicator. Following this, a comparison of in vitro excystation and animal infectivity was performed for assessing cyst viability after exposure to low-pressure u.v. irradiation. Cysts of Giardia muris were inactivated using a low-pressure u.v. light source. Giardia muris was employed as a surrogate for the human pathogen Giardia lamblia. Cyst viability was determined by both in vitro excystation and animal infectivity. Cyst doses were counted using a flow cytometer for the animal infectivity experiments. Using in vitro excystation as the viability indicator, fluences as high as approximately 200 mJ cm(-2) did not prevent some cysts from excysting, thus verifying earlier work. Using animal infectivity, u.v. fluences of 1.4, 1.9 and 2.3 mJ cm(-2) yielded log10 reductions ranging from 0.3 to >or= 4.4. Results indicate that in vitro excystation is not a reliable indicator of G. muris cyst viability after u.v. disinfection. Very low doses of u.v. light rendered G. muris cysts non-infective in the mouse model employed. Data presented represent the only complete u.v. inactivation curve for G. muris. This research provides evidence that u.v. can be an effective barrier against Giardia spp. in the treatment of drinking water supplies.
Hutchens, M P; Drennan, S L; Cambronne, E D
2015-06-01
Needleless connectors may develop bacterial contamination and cause central-line-associated bloodstream infections (CLABSI) despite rigorous application of best-practice. Ultraviolet (UV) light-emitting diodes (LED) are an emerging, increasingly affordable disinfection technology. We tested the hypothesis that a low-power UV LED could reliably eliminate bacteria on needleless central-line ports in a laboratory model of central-line contamination. Needleless central-line connectors were inoculated with Staphylococcus aureus. A 285 nm UV LED was used in calibrated fashion to expose contaminated connectors. Ports were directly applied to agar plates and flushed with sterile saline, allowing assessment of bacterial survival on the port surface and in simulated usage flow-through fluid. UV applied to needleless central-line connectors was highly lethal at 0·5 cm distance at all tested exposure times. At distances >1·5 cm both simulated flow-through and port surface cultures demonstrated significant bacterial growth following UV exposure. Logarithmic-phase S. aureus subcultures were highly susceptible to UV induction/maintenance dosing. Low-power UV LED doses at fixed time and distance from needleless central-line connector ports reduced cultivable S. aureus from >10(6) CFU to below detectable levels in this laboratory simulation of central-line port contamination. Low-power UV LEDs may represent a feasible alternative to current best-practice in connector decontamination. © 2015 The Society for Applied Microbiology.
Pulsed high voltage electric discharge disinfection of microbially contaminated liquids.
Anpilov, A M; Barkhudarov, E M; Christofi, N; Kop'ev, V A; Kossyi, I A; Taktakishvili, M I; Zadiraka, Y
2002-01-01
To examine the use of a novel multielectrode slipping surface discharge (SSD) treatment system, capable of pulsed plasma discharge directly in water, in killing micro-organisms. Potable water containing Escherichia coli and somatic coliphages was treated with pulsed electric discharges generated by the SSD. The SSD system was highly efficient in the microbial disinfection of water with a low energy utilization (eta approximately 10-4 kW h l-1). The SSD treatment was effective in the destruction of E. coli and its coliphages through the generation of u.v. radiation, ozone and free radicals. The non-thermal treatment method can be used for the eradication of micro-organisms in a range of contaminated liquids, including milk, negating the use of pasteurization. The method utilizes multipoint electric discharges capable of treating large volumes of liquid under static and flowing regimes.
Annual Progress Report, FY 1980, 1 October 1979 - 30 September 1980,
1980-10-01
coordinating an integrated pest management program, and constructing initial pilot prototypes, test models, and pro- ducing limited quantities of medical...Screening Test Based on the Ventilatory Responses of Fish . . . . . . . a & a . . . . 25 Chemistry and Molecular Biology of the Disinfection Process...Sink Unit, Surgical, Field (NSN 6545-00-935-4056), Engineering Evaluation of . . . . . . . . . . . . . . . . . . 69 Technical Feasibility Testing (TFT
Chien, Shih-Hsiang; Dzombak, David A.; Vidic, Radisav D.
2013-01-01
Abstract Recent studies have shown that treated municipal wastewater can be a reliable cooling water alternative to fresh water. However, elevated nutrient concentration and microbial population in wastewater lead to aggressive biological proliferation in the cooling system. Three chlorine-based biocides were evaluated for the control of biological growth in cooling systems using tertiary treated wastewater as makeup, based on their biocidal efficiency and cost-effectiveness. Optimal chemical regimens for achieving successful biological growth control were elucidated based on batch-, bench-, and pilot-scale experiments. Biocide usage and biological activity in planktonic and sessile phases were carefully monitored to understand biological growth potential and biocidal efficiency of the three disinfectants in this particular environment. Water parameters, such as temperature, cycles of concentration, and ammonia concentration in recirculating water, critically affected the biocide performance in recirculating cooling systems. Bench-scale recirculating tests were shown to adequately predict the biocide residual required for a pilot-scale cooling system. Optimal residuals needed for proper biological growth control were 1, 2–3, and 0.5–1 mg/L as Cl2 for NaOCl, preformed NH2Cl, and ClO2, respectively. Pilot-scale tests also revealed that Legionella pneumophila was absent from these cooling systems when using the disinfectants evaluated in this study. Cost analysis showed that NaOCl is the most cost-effective for controlling biological growth in power plant recirculating cooling systems using tertiary-treated wastewater as makeup. PMID:23781129
Chien, Shih-Hsiang; Dzombak, David A; Vidic, Radisav D
2013-06-01
Recent studies have shown that treated municipal wastewater can be a reliable cooling water alternative to fresh water. However, elevated nutrient concentration and microbial population in wastewater lead to aggressive biological proliferation in the cooling system. Three chlorine-based biocides were evaluated for the control of biological growth in cooling systems using tertiary treated wastewater as makeup, based on their biocidal efficiency and cost-effectiveness. Optimal chemical regimens for achieving successful biological growth control were elucidated based on batch-, bench-, and pilot-scale experiments. Biocide usage and biological activity in planktonic and sessile phases were carefully monitored to understand biological growth potential and biocidal efficiency of the three disinfectants in this particular environment. Water parameters, such as temperature, cycles of concentration, and ammonia concentration in recirculating water, critically affected the biocide performance in recirculating cooling systems. Bench-scale recirculating tests were shown to adequately predict the biocide residual required for a pilot-scale cooling system. Optimal residuals needed for proper biological growth control were 1, 2-3, and 0.5-1 mg/L as Cl 2 for NaOCl, preformed NH 2 Cl, and ClO 2 , respectively. Pilot-scale tests also revealed that Legionella pneumophila was absent from these cooling systems when using the disinfectants evaluated in this study. Cost analysis showed that NaOCl is the most cost-effective for controlling biological growth in power plant recirculating cooling systems using tertiary-treated wastewater as makeup.
Engineering aspects of ferrate in water and wastewater treatment - a review.
Yates, Brian J; Zboril, Radek; Sharma, Virender K
2014-01-01
There is renewed interest in the tetra-oxy compound of +6 oxidation states of iron, ferrate(VI) (Fe(VI)O4(2-)), commonly called ferrate. Ferrate has the potential in cleaner ("greener") technologies for water treatment and remediation processes, as it produces potentially less toxic byproducts than other treatment chemicals (e.g., chlorine). Ferrate has strong potential to oxidize a number of contaminants, including sulfur- and nitrogen-containing compounds, estrogens, and antibiotics. This oxidation capability of ferrate combines with its efficient disinfection and coagulation properties as a multi-purpose treatment chemical in a single dose. This review focuses on the engineering aspects of ferrate use at the pilot scale to remove contaminants in and enhance physical treatment of water and wastewater. In most of the pilot-scale studies, in-line and on-line electrochemical ferrate syntheses have been applied. In this ferrate synthesis, ferrate was directly prepared in solution from an iron anode, followed by direct addition to the contaminant stream. Some older studies applied ferrate as a solid. This review presents examples of removing a range of contaminants by adding ferrate solution to the stream. Results showed that ferrate alone and in combination with additional coagulants can reduce total suspended solids (TSS), chemical oxygen demand (COD), biological oxygen demand (BOD), and organic matter. Ferrate also oxidizes cyanide, sulfide, arsenic, phenols, anilines, and dyes and disinfects a variety of viruses and bacteria. Limitations and drawbacks of the application of ferrate in treating contaminated water on the pilot scale are also presented.
Taylor, Alicia A.; Chowdhury, Indranil; Gong, Amy S.; Cwiertny, David M.; Walker, Sharon L.
2014-01-01
Dissolved organic matter in combination with iron oxides has been shown to facilitate photochemical disinfection through the production of reactive oxygen species (ROS) under UV and visible light. However, due to the extremely short lifetime of these radicals, the disinfection effciency is limited by the successful transport of ROS to bacterial surfaces. This study was designed to quantitatively investigate three collector surfaces with various potentials to produce ROS [bare quartz, hematite (α-Fe2O3) coated quartz, and Suwannee River humic acid (SRHA)] and the effects of extracellular polymeric substance (EPS) (full or partial coating) and solution chemistry (ionic strength, IS) on the interactions between bacteria and the ROS-producing substrates. With few exceptions, bacterial deposition studies in a parallel plate (PP) flow chamber have revealed increasing cell adhesion with IS. Furthermore, interactions between collector surfaces and cells can be explained by electrostatic forces, with negatively charged SRHA reducing and positively charged α-Fe2O3 enhancing bacterial deposition significantly. Increased deposition was also observed with full EPS content, indicating the ability of EPS to facilitate interaction between cells and surfaces in the aquatic environment. In complementary disinfection studies conducted with simulated light, viability loss was observed for cells fully coated with EPS when attached to α-Fe2O3 under all IS conditions. Based upon our prior study in which EPS was found to not inhibit hydroxyl radical activity toward bacteria, we proposed that EPS might therefore promote disinfection by facilitating cell attachment to ROS-producing surfaces where higher concentrations of ROS are expected at closer proximities to reactive substrates (e.g., SRHA and α-Fe2O3). Our findings on the mechanism and controlling factors of cell interactions with photoactive substrates provide insight as to the role of ionic strength in photochemical disinfection processes. PMID:24362649
Photolytic removal of DBPs by medium pressure UV in swimming pool water.
Hansen, Kamilla M S; Zortea, Raissa; Piketty, Aurelia; Vega, Sergio Rodriguez; Andersen, Henrik Rasmus
2013-01-15
Medium pressure UV is used for controlling the concentration of combined chlorine (chloramines) in many public swimming pools. Little is known about the fate of other disinfection by-products (DBPs) in UV treatment. Photolysis by medium pressure UV treatment was investigated for 12 DBPs reported to be found in swimming pool water: chloroform, bromodichloromethane, dibromochloromethane, bromoform, dichloroacetonitrile, bromochloroacetonitrile, dibromoacetronitrile, trichloroacetonitrile, trichloronitromethane, dichloropropanone, trichloropropanone, and chloral hydrate. First order photolysis constants ranged 26-fold from 0.020 min(-1) for chloroform to 0.523 min(-1) for trichloronitromethane. The rate constants generally increased with bromine substitution. Using the UV removal of combined chlorine as an actinometer, the rate constants were recalculated to actual treatment doses of UV applied in a swimming pool. In an investigated public pool the UV dose was equivalent to an applied electrical energy of 1.34 kWh m(-3) d(-1) and the UV dose required to removed 90% of trichloronitromethane was 0.4 kWh m(-3) d(-1), while 2.6 kWh m(-3) d(-1) was required for chloral hydrate and the bromine containing haloacetonitriles and trihalomethanes ranged from 0.6 to 3.1 kWh m(-3) d(-1). It was predicted thus that a beneficial side-effect of applying UV for removing combined chlorine from the pool water could be a significant removal of trichloronitromethane, chloral hydrate and the bromine containing haloacetonitriles and trihalomethanes. Copyright © 2012 Elsevier B.V. All rights reserved.
Aghdam, Ehsan; Xiang, Yingying; Sun, Jianliang; Shang, Chii; Yang, Xin; Fang, Jingyun
2017-08-01
The formation of disinfection by-products (DBPs) from the degradation of N,N-diethyl-3-methyl benzoyl amide (DEET) and ibuprofen (IBP) by the ultraviolet irradiation (UV)/chlorine process and subsequent post-chlorination was investigated and compared with the UV/H 2 O 2 process. The pseudo first-order rate constants of the degradation of DEET and IBP by the UV/chlorine process were 2 and 3.1 times higher than those by the UV/H 2 O 2 process, respectively, under the tested conditions. This was due to the significant contributions of both reactive chlorine species (RCS) and hydroxyl radicals (HO) in the UV/chlorine process. Trichloromethane, 1,1,1-trichloro-2-propanone and dichloroacetic acid were the major known DBPs formed after 90% of both DEET and IBP that were degraded by the UV/chlorine process. Their yields increased by over 50% after subsequent 1-day post-chlorination. The detected DBPs after the degradation of DEET and IBP comprised 13.5% and 19.8% of total organic chlorine (TOCl), respectively, and the proportions increased to 19.8% and 33.9% after subsequent chlorination, respectively. In comparison to the UV/H 2 O 2 process accompanied with post-chlorination, the formation of DBPs and TOCl in the UV/chlorine process together with post-chlorination was 5%-63% higher, likely due to the generation of more DBP precursors from the attack of RCS, in addition to HO. Copyright © 2017. Published by Elsevier B.V.
Yen, Sandi; Sokolenko, Stanislav; Manocha, Bhavik; Blondeel, Eric J M; Aucoin, Marc G; Patras, Ankit; Daynouri-Pancino, Farnaz; Sasges, Michael
2014-01-01
Sterility of cell culture media is an important concern in biotherapeutic processing. In large scale biotherapeutic production, a unit contamination of cell culture media can have costly effects. Ultraviolet (UV) irradiation is a sterilization method effective against bacteria and viruses while being non-thermal and non-adulterating in its mechanism of action. This makes UV irradiation attractive for use in sterilization of cell culture media. The objective of this study was to evaluate the effect of UV irradiation of cell culture media in terms of chemical composition and the ability to grow cell cultures in the treated media. The results showed that UV irradiation of commercial cell culture media at relevant disinfection doses impacted the chemical composition of the media with respect to several carboxylic acids, and to a minimal extent, amino acids. The cumulative effect of these changes, however, did not negatively influence the ability to culture Chinese Hamster Ovary cells, as evaluated by cell viability, growth rate, and protein titer measurements in simple batch growth compared with the same cells cultured in control media exposed to visible light. © 2014 The Authors. Published by Wiley Periodicals, Inc. on behalf of American Institute of Chemical Engineers.
Phototransformation of selected pharmaceuticals during UV treatment of drinking water.
Canonica, Silvio; Meunier, Laurence; von Gunten, Urs
2008-01-01
The kinetics of Ultraviolet C (UV-C)-induced direct phototransformation of four representative pharmaceuticals, i.e., 17alpha-ethinylestradiol (EE2), diclofenac, sulfamethoxazole, and iopromide, was investigated in dilute solutions of pure water buffered at various pH values using a low-pressure and a medium-pressure mercury arc lamp. Except for iopromide, pH-dependent rate constants were observed, which could be related to acid-base equilibria. Quantum yields for direct phototransformation were found to be largely wavelength-independent, except for EE2. This compound, which also had a rather inefficient direct phototransformation, mainly underwent indirect phototransformation in natural water samples, while the UV-induced depletion of the other pharmaceuticals appeared to be unaffected by the presence of natural water components. At the UV-C (254 nm) drinking-water disinfection fluence (dose) of 400 Jm(-2), the degree of depletion of the select pharmaceuticals at pH=7.0 in pure water was 0.4% for EE2, 27% for diclofenac, 15% for sulfamethoxazole, and 15% for iopromide, indicating that phototransformation should be seriously taken into account when evaluating the possibility of formation of UV transformation products from pharmaceuticals present as micropollutants.
Abd-Elmaksoud, Sherif; Naranjo, Jaime E; Gerba, Charles P
2013-06-01
Effective individual microbiological water purifiers are needed for consumption of untreated water sources by campers, emergency use, military, and in developing counties. A handheld UV light device was tested to assess if it could meet the virus reduction requirements established by the United State Environmental Protection Agency, National Science Foundation and the World Health Organization. The device was found capable of inactivating at least 4 log₁₀ of poliovirus type 1, rotavirus SA-11 and MS-2 virus in 500 mL volumes of general case test water. But in the presence of high turbidity and organic matter, filtration was necessary to achieve a 4 log₁₀ reduction of the test viruses.
Hopkins, Zachary R; Snowberger, Sebastian; Blaney, Lee
2017-09-15
UV-filters (UVFs) are active ingredients in personal care products that protect skin from exposure to UV light. Environmentally-relevant concentrations of UVFs have recently been linked to toxicity in aquatic organisms, necessitating research into improved UVF removal in water/wastewater treatment. Here, we investigated ozonation of the three most commonly employed UVFs: octinoxate (OMC), octocrylene (OC), and oxybenzone (OXY). Specific second-order rate constants for UVF reaction with ozone were identified as follows: OMC, 5.25×10 4 M -1 s -1 ; OC, 1.58M -1 s -1 ; OXY (neutral), 3.80×10 2 M -1 s -1 ; and, OXY (anion), 1.51×10 6 M -1 s -1 . These kinetic parameters indicated that OMC and OXY undergo significant (2-log or greater) transformation for typical ozone exposures in disinfection processes; however, minimal oxidation is expected for OC. UV absorbance mapping was employed to characterize the loss of UVF activity (i.e., absorbance across the UV-A, UV-B, and UV-C ranges) during ozonation. These 4-dimensional maps also confirmed ozone attack mechanisms, namely reaction at phenolate (OXY) and olefin (OMC, OC) groups. Primary transformation products from these reactions were identified for all three UVFs of concern. For OC and OXY, the benzophenone structure is conserved, suggesting that transformation products retain toxicity concerns. Copyright © 2017 Elsevier B.V. All rights reserved.
Physical and biological characterization of a seawater ultraviolet radiation sterilizer
NASA Astrophysics Data System (ADS)
Torrentera, Laura; Uribe, Roberto M.; Rodríguez, Romana R.; Carrillo, Ricardo E.
1994-03-01
The physical and biological characterization of a seawater ultraviolet (UV) sterilizer is described. The physical characterization was performed using radiochromic dye films by evaluating the uniformity of the radiant exposure along each lamp, the effect of the radiation from one lamp on the array of adjacent lamps, and by measuring the UV radiation absorption of seawater with respect to distilled water. The biological characterization was performed by measuring the amount of reduction of bacteria in stored seawater after different filtration and UV treatments. Among the filtration methods tested, differential filtration (5, 3 and 0.45 μm filters connected in series) caused the highest bacterial reduction factor of 60%. UV radiant exposures of 212, 424, 636 and 848 J m -2 yielded bacteria reduction factors of 99.86, 99.969, 99.997 and 100%, respectively, for populations of Vibrio and Pseudomonas bacteria present in stored seawater. It is concluded that the system is useful for water disinfection when 1, 2 or 3 lamps are on; when 4 lamps are used the treated water becomes sterile.
Cathodoluminescent UV-radiation sources
NASA Astrophysics Data System (ADS)
Vereschagina, N. Y.; Danilkin, M. I.; Kazaryan, M. A.; Ozol, D. I.; Sheshin, E. P.; Spassky, D. A.
2018-04-01
Mercury-free UV-radiation sources are described. An electron beam similar to cathode-ray tubes (CRT) excites a luminescent material in a vacuum bulb. A high density of excitation requires the cathode and the luminescent material to be resistant for that and provide the extended lifetime of the UV-radiation source. Carbon fibre and nano-carbon based field-emission cathodes produce long lasting stable emission with a high current density (up to 0.3-0.5 A/cm2 ). Li2B4O7:Cu and Li2B4O7:Ag luminescent ceramics survive under high radiation doses and provide UV luminescence bands peaked at 360-370 nm and 270 nm, respectively. The luminescence band at 360-370 nm has a good overlap with the fundamental absorption edge of TiO2, which is known as a photo-catalyst in air and water cleaning systems. The luminescence band at 270 nm overlaps with DNA absorption and provides a direct disinfection effect. We suggest the structure of complex luminescence centres and energy transfer mechanisms. The electron structure of lithium tetraborate and the contribution of impurities are also discussed in paper.
Liou, Je-Wen; Chang, Hsin-Hou
2012-08-01
This review focuses on the antibacterial activities of visible light-responsive titanium dioxide (TiO(2)) photocatalysts. These photocatalysts have a range of applications including disinfection, air and water cleaning, deodorization, and pollution and environmental control. Titanium dioxide is a chemically stable and inert material, and can continuously exert antimicrobial effects when illuminated. The energy source could be solar light; therefore, TiO(2) photocatalysts are also useful in remote areas where electricity is insufficient. However, because of its large band gap for excitation, only biohazardous ultraviolet (UV) light irradiation can excite TiO(2), which limits its application in the living environment. To extend its application, impurity doping, through metal coating and controlled calcination, has successfully modified the substrates of TiO(2) to expand its absorption wavelengths to the visible light region. Previous studies have investigated the antibacterial abilities of visible light-responsive photocatalysts using the model bacteria Escherichia coli and human pathogens. The modified TiO(2) photocatalysts significantly reduced the numbers of surviving bacterial cells in response to visible light illumination. They also significantly reduced the activity of bacterial endospores; reducing their toxicity while retaining their germinating abilities. It is suggested that the photocatalytic killing mechanism initially damages the surfaces weak points of the bacterial cells, before totally breakage of the cell membranes. The internal bacterial components then leak from the cells through the damaged sites. Finally, the photocatalytic reaction oxidizes the cell debris. In summary, visible light-responsive TiO(2) photocatalysts are more convenient than the traditional UV light-responsive TiO(2) photocatalysts because they do not require harmful UV light irradiation to function. These photocatalysts, thus, provide a promising and feasible approach for disinfection of pathogenic bacteria; facilitating the prevention of infectious diseases.
Kim, Do-Kyun; Kim, Soo-Ji; Kang, Dong-Hyun
2017-01-01
In order to assure the microbial safety of drinking water, UVC-LED treatment has emerged as a possible technology to replace the use of conventional low pressure (LP) mercury vapor UV lamps. In this investigation, inactivation of Human Enteric Virus (HuEV) surrogates with UVC-LEDs was investigated in a water disinfection system, and kinetic model equations were applied to depict the surviving infectivities of the viruses. MS2, Qβ, and ΦX 174 bacteriophages were inoculated into sterile distilled water (DW) and irradiated with UVC-LED printed circuit boards (PCBs) (266nm and 279nm) or conventional LP lamps. Infectivities of bacteriophages were effectively reduced by up to 7-log after 9mJ/cm 2 treatment for MS2 and Qβ, and 1mJ/cm 2 for ΦX 174. UVC-LEDs showed a superior viral inactivation effect compared to conventional LP lamps at the same dose (1mJ/cm 2 ). Non-log linear plot patterns were observed, so that Weibull, Biphasic, Log linear-tail, and Weibull-tail model equations were used to fit the virus survival curves. For MS2 and Qβ, Weibull and Biphasic models fit well with R 2 values approximately equal to 0.97-0.99, and the Weibull-tail equation accurately described survival of ΦX 174. The level of UV-susceptibility among coliphages measured by the inactivation rate constant, k, was statistically different (ΦX 174 (ssDNA)>MS2, Qβ (ssRNA)), and indicated that sensitivity to UV was attributed to viral genetic material. Copyright © 2016 Elsevier Ltd. All rights reserved.
Maizel, Andrew C; Remucal, Christina K
2017-10-01
There is a growing interest in water reuse and in recovery of nutrients from wastewater. Because many advanced treatment processes are designed to remove organic matter, a better understanding of the composition of dissolved organic matter (DOM) in wastewater is needed. To that end, we assessed DOM in the Nine Springs Wastewater Treatment Plant in Madison, Wisconsin by UV-visible spectroscopy and Fourier transform-ion cyclotron resonance mass spectrometry. Samples were collected from the influent and effluent of two different secondary treatment processes and their respective secondary clarifiers, the UV disinfection unit, and an Ostara treatment system, which produces struvite via chemical precipitation. The optical properties reveal that DOM throughout the plant is relatively aliphatic and is low in molecular weight compared to DOM in freshwater systems. Furthermore, the DOM is rich in heteroatoms (e.g., N, S, P, and Cl) and its molecular formulas are present in the lipid-, protein-, carbohydrate-, and lignin-like regions of van Krevelen diagrams. Secondary treatment produces DOM that is more aromatic and more complex, as shown by the loss of highly saturated formulas and the increase in the number of CHO, CHON, and CHOP formulas. The two secondary treatment processes produce DOM with distinct molecular compositions, while the secondary clarifiers and UV disinfection unit result in minimal changes in DOM composition. The Ostara process decreases the molecular weight of DOM, but does not otherwise alter its composition. The optical properties agree with trends in the molecular composition of DOM within the main treatment train of the Nine Springs plant. Copyright © 2017 Elsevier Ltd. All rights reserved.
Iskander, Syeed Md; Novak, John T; Brazil, Brian; He, Zhen
2017-11-01
The presence of UV quenching compounds in landfill leachate can negatively affect UV disinfection in a wastewater treatment plant when leachate is co-treated. Herein, a microbial fuel cell (MFC) was investigated to remove UV quenchers from a landfill leachate with simultaneous bioelectricity generation. The key operating parameters including hydraulic retention time (HRT), anolyte recirculation rate, and external resistance were systematically studied to maximize energy recovery and UV absorbance reduction. It was found that nearly 50% UV absorbance was reduced under a condition of HRT 40 days, continuous anolyte recirculation, and 10 Ω external resistance. Further analysis showed a total reduction of organics by 75.3%, including the reduction of humic acids, fulvic acids, and hydrophilic fraction concentration as TOC. The MFC consumed 0.056 kWh m -3 by its pump system for recirculation and oxygen supply. A reduced HRT of 20 days with periodical anode recirculation (1 hour in every 24 hours) and 39 Ω external resistance (equal to the internal resistance of the MFC) resulted in the highest net energy of 0.123 kWh m -3 . Granular activated carbon (GAC) was used as an effective post-treatment step and could achieve 89.1% UV absorbance reduction with 40 g L -1 . The combined MFC and GAC treatment could reduce 92.9% of the UV absorbance and remove 89.7% of the UV quenchers. The results of this study would encourage further exploration of using MFCs as an energy-efficient method for removing UV quenchers from landfill leachate.
Jung, Chanil; Deng, Yang; Zhao, Renzun; Torrens, Kevin
2017-01-01
UV-quenching substance (UVQS), as an emerging municipal solid waste (MSW)-derived leachate contaminant, has a potential to interfere with UV disinfection when leachate is disposed of at publicly owned treatment works (POTWs). The objective of this study was to evaluate and compare two chemical oxidation processes under different operational conditions, i.e. Fenton process and ozonation, for alleviation of UV 254 absorbance of a biologically pre-treated landfill leachate. Results showed that leachate UV 254 absorbance was reduced due to the UVQS decomposition by hydroxyl radicals (·OH) during Fenton treatment, or by ozone (O 3 ) and ·OH during ozonation. Fenton process exhibited a better treatment performance than ozonation under their respective optimal conditions, because ·OH could effectively decompose both hydrophobic and hydrophilic dissolved organic matter (DOM), but O 3 tended to selectively oxidize hydrophobic compounds alone. Different analytical techniques, including molecular weight (MW) fractionation, hydrophobic/hydrophilic isolation, UV spectra scanning, parallel factor (PARAFAC) analysis, and fluorescence excitation-emission matrix spectrophotometry, were used to characterize UVQS. After either oxidation treatment, residual UVQS was more hydrophilic with a higher fraction of low MW molecules. It should be noted that the removed UV 254 absorbance (ΔUV 254 ) was directly proportional to the removed COD (ΔCOD) for the both treatments (Fenton process: ΔUV 254 = 0.011ΔCOD; ozonation: ΔUV 254 = 0.016ΔCOD). A greater ΔUV 254 /ΔCOD was observed for ozonation, suggesting that oxidant was more efficiently utilized during ozonation than in Fenton treatment for mitigation of the UV absorbance. Copyright © 2016 Elsevier Ltd. All rights reserved.
Banach, Marcin; Tymczyna, Leszek; Chmielowiec-Korzeniowska, Anna; Pulit-Prociak, Jolanta
2016-01-01
The aim of this study was to use aqueous suspensions of silver nanoparticles with a wide spectrum of particle sizes, variable morphology, high stability, and appropriate physicochemical properties to examine their bactericidal and fungicidal properties against microorganisms present in poultry processing plants. At the same time, the particles were tested for preventing the production of odorogenous pollutants during incubation and thereby reducing the emission of harmful gases from such types of facilities. The results show that the use of nanosilver preparations in order to disinfect eggs and hatchers reduced microbiological contamination. The bactericidal and fungicidal efficacy of the applied preparation was comparable to UV radiation and its effectiveness increasing during the incubation. Good results were achieved in terms of the level of organic gaseous contaminants, which decreased by 86% after the application of the nanosilver preparation. PMID:26903785
NASA Astrophysics Data System (ADS)
Marais, Savia S.; Ncube, Esper J.; Haarhoff, Johannes; Msagati, Titus AM; Mamba, Bhekie B.; Nkambule, Thabo I.
2016-04-01
Certain disinfection by-products (DBPs) are likely human carcinogens or present mutagenic effects while many DBPs are unidentified. Considering the possibility of DBPs being harmful to human health and the fact that trihalomethanes (THMs) are the only regulated DBP in the South African National Standard (SANS:241) for drinking water, special interest in the precursors to these DBPs' formation is created. It is essential to understand the reactivity and character of the precursors responsible for the formation of DBPs in order to enhance precursor removal strategies during the treatment of drinking water. In this study the character of NOM within surface water and the subsequent distribution of THMs formed in the drinking water from Rand Waters' full scale treatment plant were investigated. Molecular size distribution (MSD) of NOM within the surface water was determined by high performance size exclusion chromatography (HPSEC). Specific ultraviolet absorbance (SUVA) and UV254 measurements formed part of the NOM character study as they provide an indication of the aromaticity of organic matter. The four THMs; bromoform, chloroform, dibromochloromethane (DBCM) and bromodichloromethane (BDCM)were measured by gas chromatography. The sum of these four THMs was expressed as total trihalomethane (TTHM). On average the chloroform constituted 76.2% of the total TTHM, BDCM 22.5% while DBCM and bromoform measured below the detection limit. THM speciation after chlorination and chloramination concentrations increased in the sequence bromoform < DBCM < BDCM < chloroform. Results of the MSD showed a significant correlation between NOM of high molecular size (peak I) and TTHM formation specifically during the summer months (R2= 0.971, p < 0.05). High molecular weight (HMW) NOM also related well to chloroform formation (R2 = 0.963, p < 0.05) however, the formation of BDCM was not due to HWM fraction as indicated by weak regression coefficient. A positive correlation existed between SUVA and UV254 removal percentage (R2 = 0.937, p < 0.05). Seasonal variability in NOM character was evident in the source water in summer when high temperatures and rainfall occurred. The results displayed are an indication that aromatic NOM were the main precursor to TTHM formation, more prominently during summer. Keywords: disinfection by-products, molecular size distribution, natural organic matter, UV254
Rodríguez-Chueca, J; García-Cañibano, C; Lepistö, R-J; Encinas, Á; Pellinen, J; Marugán, J
2018-04-21
This study explores the enhancement of UV-C tertiary treatment by sulfate radical based Advanced Oxidation Processes (SR-AOPs), including photolytic activation of peroxymonosulfate (PMS) and persulfate (PS) and their photocatalytic activation using Fe(II). Their efficiency was assessed both for the inactivation of microorganisms and the removal or micropollutants (MPs) in real wastewater treatment plant effluents. Under the studied experimental range (UV-C dose 5.7-57 J/L; UV-C contact time 3 to 28 s), the photolysis of PMS and PS (0.01 mM) increased up to 25% the bacterial removal regarding to UV-C system. The photolytic activation of PMS led to the total inactivation of bacteria (≈ 5.70 log) with the highest UV-C dose (57 J/L). However, these conditions were insufficient to remove the MPs, being required oxidant's dosages of 5 mM to remove above 90% of carbamazepine, diclofenac, atenolol and triclosan. The best efficiencies were achieved by the combination of PMS or PS with Fe(II), leading to the total removal of the MPs using a low UV-C dosage (19 J/L), UV-C contact time (9 s) and reagent's dosages (0.5 mM). Finally, high mineralization was reached (>50%) with photocatalytic activation of PMS and PS even with low reagent's dosages. Copyright © 2018 Elsevier B.V. All rights reserved.
Durán, A; Monteagudo, J M; San Martín, I
2012-05-15
The aim of this work was to study the operation costs of treating a real effluent from an integrated gasification combined cycle (IGCC) power station located in Spain. The study compares different homogeneous photocatalytic processes on a pilot plant scale using different types of radiation (artificial UV or solar UV with a compound parabolic collector). The efficiency of the processes was evaluated by an analysis of the total organic carbon (TOC) removed. The following processes were considered in the study: (i) a photo-Fenton process at an artificial UV pilot plant (with the initial addition of H(2)O(2)), (ii) a modified photo-Fenton process with continuous addition of H(2)O(2) and O(2) to the system and (iii) a ferrioxalate-assisted solar photo-Fenton process at a compound parabolic collector (CPC) pilot plant. The efficiency of these processes in degrading pollutants has been studied previously, and the results obtained in each of those studies have been published elsewhere. The operational costs due to the consumption of electrical energy, reagents and catalysts were calculated from the optimal conditions of each process. The results showed that the solar photo-Fenton system was economically feasible, being able to achieve up to 75% mineralization with a total cost of 6 €/m(3), which can be reduced to 3.6 €/m(3) by subtracting the electrical costs because the IGCC plant is self-sufficient in terms of energy. Copyright © 2011 Elsevier Ltd. All rights reserved.
Surface processing: existing and potential applications of ultraviolet light.
Manzocco, Lara; Nicoli, Maria Cristina
2015-01-01
Solid foods represent optimal matrices for ultraviolet processing with effects well beyond nonthermal surface disinfection. UV radiation favors hormetic response in plant tissues and degradation of toxic compound on the product surface. Photoinduced reactions can also provide unexplored possibilities to steer structure and functionality of food biopolymers. The possibility to extensively exploit this technology will depend on availability of robust information about efficacious processing conditions and adequate strategies to completely and homogeneously process food surface.
NASA Technical Reports Server (NTRS)
Flanagan, David T. (Inventor); Gibbons, Randall E. (Inventor)
1992-01-01
A system for prolonging the life of a granulated activated charcoal (GAC) water treatment device is disclosed in which an ultraviolet light transparent material is used to constrain water to flow over carbon surfaces. It is configured to receive maximum flux from a UV radiation source for the purpose of preventing microbial proliferation on the carbon surfaces; oxidizing organic contaminants adsorbed from the water onto the carbon surfaces and from biodegradation of adsorbed microbial forms; disinfecting water; and oxidizing organic contaminants in the water.
Jeznach, Lillian C; Hagemann, Mark; Park, Mi-Hyun; Tobiason, John E
2017-10-01
Extreme precipitation events are of concern to managers of drinking water sources because these occurrences can affect both water supply quantity and quality. However, little is known about how these low probability events impact organic matter and nutrient loads to surface water sources and how these loads may impact raw water quality. This study describes a method for evaluating the sensitivity of a water body of interest from watershed input simulations under extreme precipitation events. An example application of the method is illustrated using the Wachusett Reservoir, an oligo-mesotrophic surface water reservoir in central Massachusetts and a major drinking water supply to metropolitan Boston. Extreme precipitation event simulations during the spring and summer resulted in total organic carbon, UV-254 (a surrogate measurement for reactive organic matter), and total algae concentrations at the drinking water intake that exceeded recorded maximums. Nutrient concentrations after storm events were less likely to exceed recorded historical maximums. For this particular reservoir, increasing inter-reservoir transfers of water with lower organic matter content after a large precipitation event has been shown in practice and in model simulations to decrease organic matter levels at the drinking water intake, therefore decreasing treatment associated oxidant demand, energy for UV disinfection, and the potential for formation of disinfection byproducts. Copyright © 2017 Elsevier Ltd. All rights reserved.
Glutaraldehyde degradation in hospital wastewater by photoozonation.
Kist, Lourdes Teresinha; Rosa, Ellen Caroline; Machado, Enio Leandro; Camargo, Maria Emilia; Moro, Celso Camilo
2013-01-01
In this paper, we assessed aqueous solutions of glutaraldehyde (GA), a chemical used for the disinfection of hospital materials, using advanced oxidative processes, O3, and UV, and the combination of the latter two. Assays with different ozone concentrations at distinct pH levels were conducted to determine the best treatment process. GA concentrations before and after each treatment were measured by spectrophotometry. The best treatment was that which combined O3 and UV, yielding a degradation of 72.0-75.0% in relation to the initial concentration with pH between 4 and 9. Kinetics demonstrated that GA degradation is not dependent on pH, as there was a first-order reaction with a rate constant of k = 0.0180 min(-1) for initial pH 9 and of k = 0.0179 min(-1) for initial pH 7, that is, the values are virtually the same. Secondary wastewater samples were also analysed using the septic tank/filter system of a regional hospital in Vale do Rio Pardo, state of Rio Grande do Sul, southern Brazil. In this case, the characteristics of the wastewater were described and, after treatment, a GA degradation rate of 23.3% was noted, with reductions of 75% for chemical oxygen demand, 81% for biochemical oxygen demand, 68% for turbidity, 70% for surfactants and total disinfection in terms of thermotolerant coliforms.
Evaluating UV-C LED disinfection performance and ...
This study evaluated ultraviolet (UV) light emitting diodes (LEDs) emitting at 260 nm, 280 nm, and the combination of 260|280 nm together for their efficacy at inactivating Escherichia. coli, MS2 coliphage, human adenovirus type 2 (HAdV2), and Bacillus pumilus spores; research included an evaluation of genomic damage. Inactivation by the LEDs was compared with the efficacy of conventional UV sources, the low-pressure (LP) and medium-pressure (MP) mercury vapor lamps. The work also calculated the electrical energy per order of reduction of the microorganisms by the five UV sources.For E. coli, all five UV sources yielded similar inactivation rates. For MS2 coliphage, the 260 nm LED was most effective. For HAdV2 and B. pumilus, the MP UV lamp was significantly more effective than the LP UV and UVC LED sources. When considering electrical energy per order of reduction, the LP UV lamp was the most efficient for E. coli and MS2, and the MPUV and LPUV were equally efficient for HAdV2 and B. pumilus spores. Among the UVC LEDs, the 280 nm LED unit required the least energy per log reduction of E. coli and HAdV2. The 280 nm and 260|280 nm LED units were equally efficient per log reduction of B. pumilus spores, and the 260 nm LED unit required the lowest energy per order of reduction of MS2 coliphage. The combination of the 260 nm and 280 nm UV LED wavelengths was also evaluated for potential synergistic effects. No dual-wavelength synergy was detected for inactivation of
Rostad, C.E.; Martin, B.S.; Barber, L.B.; Leenheer, J.A.; Daniel, S.R.
2000-01-01
The fate of halogenated disinfection byproducts (DBPs) in treatment wetlands and the changes in the DBP formation potential as wastewater treatment plant (WWTP)-derived water moves through the wetlands were investigated. Wetland inlet and outlet samples were analyzed for total organic halide (TOX), trihalomethanes (TH M), haloacetic acids (HAA), dissolved organic carbon (DOC), and UV absorbance. Removal of DBPs by the wetland ranged from 13 to 55% for TOX, from 78 to 97% for THM, and from 67 to 96% for HAA. The 24-h and 7-day nonpurgeable total organic halide (NPTOX), THM, and HAA formation potential yields were determined at the inlet and outlet of these wetlands. The effect of wetlands on the production of DBP precursors and their DBP-formation potential yield from wastewater was dramatic. The wetlands increased DBP yield up to a factor of almost 30. Specific changes in the DOC precursors were identified using 13C NMR spectroscopy.The fate of halogenated disinfection byproducts (DBPs) in treatment wetlands and the changes in the DBP formation potential as wastewater treatment plant (WWTP)-derived water moves through the wetlands were investigated. Wetland inlet and outlet samples were analyzed for total organic halide (TOX), trihalomethanes (THM), haloacetic acids (HAA), dissolved organic carbon (DOC), and UV absorbance. Removal of DBPs by the wetland ranged from 13 to 55% for TOX, from 78 to 97% for THM, and from 67 to 96% for HAA. The 24-h and 7-day nonpurgeable total organic halide (NPTOX), THM, and HAA formation potential yields were determined at the inlet and outlet of these wetlands. The effect of wetlands on the production of DBP precursors and their DBP-formation potential yield from wastewater was dramatic. The wetlands increased DBP yield up to a factor of almost 30. Specific changes in the DOC precursors were identified using 13C NMR spectroscopy.
NASA Technical Reports Server (NTRS)
Hicks, A. K.; Mushotzky, R.
2006-01-01
We have analyzed XMM-Newton Optical Monitor (OM) UV (180-400 nm) data for a sample of 33 galaxies. 30 are cluster member galaxies, and nine of these are central cluster galaxies (CCGs) in cooling flow clusters having mass deposition rates which span a range of 8 - 525 Solar Mass/yr. By comparing the ratio of UV to 2MASS J band fluxes, we find a significant UV excess in many, but not all, cooling flow CCGs, a finding consistent with the outcome of previous studies based on optical imaging data (McNamara & O'Connell 1989; Cardiel, Gorgas, & Aragon-Salamanca 1998; Crawford et al. 1999). This UV excess is a direct indication of the presence of young massive stars, and therefore recent star formation, in these galaxies. Using the Starburst99 spectral energy distribution (SED) model of continuous star formation over a 900 Myr period, we derive star formation rates of 0.2 - 219 solar Mass/yr for the cooling flow sample. For 2/3 of this sample it is possible to equate Chandra/XMM cooling flow mass deposition rates with UV inferred star formation rates, for a combination of starburst lifetime and IMF slope. This is a pilot study of the well populated XMM UV cluster archive and a more extensive follow up study is currently underway.
The photovoltaic pilot projects of the European Community
NASA Astrophysics Data System (ADS)
Schnell, W.
The Commission of the European Communities has started in 1980 a programme for the design and construction of a series of photovoltaic pilot projects in the range of 30-300 kWp. Virtually all important industries and other development organisations in Europe working on photovoltaic cells and systems are involved in this programme. The different technologies which are being developed concern the modules, the cabling of the array, structure design, storage strategy and power conditioning. The various applications include powering of an island, villages, recreation centres, water desalination and disinfection, powering of radio transmitters, emergency power plants, dairy farm, training school, cooling, water pumping, powering of a solar heated swimming pool and last but not least, hydrogen production.
Formation of iodinated trihalomethanes during UV/chloramination with iodate as the iodine source.
Zhang, Tian-Yang; Lin, Yi-Li; Wang, An-Qi; Tian, Fu-Xiang; Xu, Bin; Xia, Sheng-Ji; Gao, Nai-Yun
2016-07-01
Iodinated trihalomethanes (I-THMs) are a group of emerging disinfection by-products with high toxicity, and iodide (I(-)) as well as iodinated organic compounds are expected to be their iodine sources. Nevertheless, in this study, iodate (IO3(-)) was proven to be a new iodine source of I-THM formation during UV/chloramination. In the iodate-containing waters (without any other iodine sources), I-THM formation increased with the increase of UV dose, IO3(-) and NH2Cl concentrations. With the increase of Br(-)/IO3(-) molar ratio, I-THM formation (especially for the brominated species) increased. Besides, NOM species could affect I-THM formation from IO3(-) during UV/chloramination. Fulvic acid could promote IO3(-) phototransformation to I(-) but humic acid impeded the production of I(-) during UV irradiation. Under realistic drinking water treatment conditions (DOC = 5.0 mg-C/L, IO3(-) = 12.7 μg-I/L, UV dose = 50 mJ/cm(2), NH2Cl = 5 mg-Cl2/L), CHCl2I was detected as 0.17 μg/L using solid-phase microextraction method, and the production rate of I-THMs from IO3(-) was about 7% of that from I(-). Copyright © 2016 Elsevier Ltd. All rights reserved.
Efficacy of Inactivation of Human Enteroviruses by Multiple ...
Background: Ultraviolet (UV) light has been successfully used for treating a broad suite of pathogens without the concomitant formation of carcinogenic disinfection by-products (DBPs). However, conventional mercury UV lamps have some practical limitations in water treatment applications, such as the inefficiency of energy consumption and more importantly potential mercury contamination upon disposal of the lamps. The recent invention of a novel light-emitting-diodes (LED) device generating germicidal UV wavelengths could eliminate the aforementioned limitations. In this study, we investigated the efficacy of multiple-wavelength UV LEDs for inactivating USEPA contaminant candidate list (CCL) RNA enteroviruses.Methods: Of 12 enterovirus species, serotype representatives of the four human enteric species (enterovirus A-D) such as coxsackievirus A10 (CVA10), echovirus 30 (Echo30), poliovirus 1 (PV1), and enterovirus 70 (EV70) respectively were selected as testing RNA viruses. Bench-scale performance evaluation was conducted using a collimated beam (CB) apparatus with LEDs emitting at 260 nm, 280 nm, and the combination of 260|280 nm together, as well as a monochromatic low-pressure (LP) UV lamp at 254 nm for comparison. The CB tests were performed with mixed stocks of four viruses. Infectious virus concentrations were determined using an integrated cell culture reverse transcriptase quantitative PCR (ICC-RTqPCR).Results: The 260 nm LED was most effective at inactiva
Efficacy of Inactivation of Human Enteroviruses by Multiple ...
Ultraviolet (UV) light has been successfully used for treating a broad suite of pathogens without the concomitant formation of carcinogenic disinfection by-products (DBPs). However, conventional mercury UV lamps have some practical limitations in water treatment applications, such as the inefficiency of energy consumption and more importantly potential mercury contamination upon disposal of the lamps. The recent invention of a novel light-emitting-diodes (LED) device generating germicidal UV wavelengths could eliminate the aforementioned limitations. In this study, we investigated the efficacy of multiple-wavelength UV LEDs for inactivating USEPA contaminant candidate list (CCL) RNA enteroviruses. Of 12 enterovirus species, serotype representatives of the four human enteric species (enterovirus A-D) such as coxsackievirus A10 (CVA10), echovirus 30 (Echo30), poliovirus 1 (PV1), and enterovirus 70 (EV70) respectively were selected as testing RNA viruses. Bench-scale performance evaluation was conducted using a collimated beam (CB) apparatus with LEDs emitting at 260 nm, 280 nm, and the combination of 260|280 nm together, as well as a monochromatic low-pressure (LP) UV lamp at 254 nm for comparison. The CB tests were performed with mixed stocks of four viruses. Infectious virus concentrations were determined using an integrated cell culture reverse transcriptase quantitative PCR (ICC-RTqPCR). The 260 nm LED was most effective at inactivating all enteroviruses teste
Efficient photoreductive decomposition of N-nitrosodimethylamine by UV/iodide process.
Sun, Zhuyu; Zhang, Chaojie; Zhao, Xiaoyun; Chen, Jing; Zhou, Qi
2017-05-05
N-nitrosodimethylamine (NDMA) has aroused extensive concern as a disinfection byproduct due to its high toxicity and elevated concentration levels in water sources. This study investigates the photoreductive decomposition of NDMA by UV/iodide process. The results showed that this process is an effective strategy for the treatment of NDMA with 99.2% NDMA removed within 10min. The depletion of NDMA by UV/iodide process obeyed pseudo-first-order kinetics with a rate constant (k 1 ) of 0.60±0.03min -1 . Hydrated electrons (e aq - ) generated by the UV irradiation of iodide were proven to play a critical role. Dimethylamine (DMA) and nitrite (NO 2 - ) were formed as the main intermediate products, which completely converted to formate (HCOO - ), ammonium (NH 4 + ) and nitrogen (N 2 ). Therefore, not only the high efficiencies in NDMA destruction, but the elimination of toxic intermediates make UV/iodide process advantageous. A photoreduction mechanism was proposed: NDMA initially absorbed photons to a photoexcited state, and underwent a cleavage of NNO bond under the attack of e aq - . The solution pH had little impact on NDMA removal. However, alkaline conditions were more favorable for the elimination of DMA and NO 2 - , thus effectively reducing the secondary pollution. Copyright © 2016 Elsevier B.V. All rights reserved.
Tang, Yuqing; Shi, Xueting; Liu, Yongze; Zhang, Liqiu
2018-01-01
As a potential endocrine disruptor, clofibric acid (CA) was investigated in this study for its degradation kinetics and pathways in UV/chlorine process. The results showed that CA in both UV photolysis and UV/chlorine processes could be degraded via pseudo-first-order kinetics, while it almost could not be degraded in the dark chlorination process. The observed rate constant (kobs) in UV photolysis was 0.0078 min−1, and increased to 0.0107 min−1 combining with 0.1 mM chlorine. The kobs increased to 0.0447 min−1 with further increasing the chlorine dosage from 0.1 to 1.0 mM, and reached a plateau at higher dosage (greater than 1.0 mM). The higher kobs was obtained at acid solution rather than basic solution. Moreover, the calculated contributions of radical species to kobs indicated that the HO• contributed significantly to CA degradation in acidic conditions, while the reactive chlorine species and UV direct photolysis dominated in neutral and basic solution. The degradation of CA was slightly inhibited in the presence of HCO3− (1 ∼ 50 mM), barely affected by the presence of Cl− (1 ∼ 200 mM) and greatly suppressed by humic acid (0 ∼ 5 mg l−1). Thirteen main degradation intermediates and three degradation pathways of CA were identified during UV/chlorine process. PMID:29515853
Tang, Yuqing; Shi, Xueting; Liu, Yongze; Feng, Li; Zhang, Liqiu
2018-02-01
As a potential endocrine disruptor, clofibric acid (CA) was investigated in this study for its degradation kinetics and pathways in UV/chlorine process. The results showed that CA in both UV photolysis and UV/chlorine processes could be degraded via pseudo-first-order kinetics, while it almost could not be degraded in the dark chlorination process. The observed rate constant ( k obs ) in UV photolysis was 0.0078 min -1, and increased to 0.0107 min -1 combining with 0.1 mM chlorine. The k obs increased to 0.0447 min -1 with further increasing the chlorine dosage from 0.1 to 1.0 mM, and reached a plateau at higher dosage (greater than 1.0 mM). The higher k obs was obtained at acid solution rather than basic solution. Moreover, the calculated contributions of radical species to k obs indicated that the HO• contributed significantly to CA degradation in acidic conditions, while the reactive chlorine species and UV direct photolysis dominated in neutral and basic solution. The degradation of CA was slightly inhibited in the presence of [Formula: see text] (1 ∼ 50 mM), barely affected by the presence of Cl - (1 ∼ 200 mM) and greatly suppressed by humic acid (0 ∼ 5 mg l -1 ). Thirteen main degradation intermediates and three degradation pathways of CA were identified during UV/chlorine process.
Assemany, Paula Peixoto; Calijuri, Maria Lúcia; Santiago, Anibal da Fonseca; do Couto, Eduardo de Aguiar; Leite, Mauricio de Oliveira; Sierra, Jose Jovanny Bermudez
2014-01-01
The objective of this paper is to compare the lipid content and composition ofbiomass produced by a consortium of microalgae and bacteria, cultivated under different solar radiation intensities and tropical conditions in pilot-scale high-rate ponds (HRPs) using domestic sewage as culture medium. The treatment system consisted of an upflow anaerobic sludge blanket reactor followed by UV disinfection and six HRPs covered with shading screens that blocked 9%, 18%, 30%, 60% and 80% of the solar radiation. The total lipid content does not vary significantly among the units, showing a medium value of 9.5%. The results show that blocking over 30% of the solar radiation has a negative effect on the lipid productivity. The units with no shading and with 30% and 60% of solar radiation blocking have statistically significant lipid productivities, varying from 0.92 to 0.96 gm(-2) day(-1). Besides radiation, other variables such as volatile suspended solids and chlorophyll-a are able to explain the lipid accumulation. The lipid profile has a predominance of C16, C18:1 and C18:3 acids. The unsaturation of fatty acids increases with the reduction in solar radiation. On the other hand, the effect of polyunsaturation is not observed, which is probably due to the presence of a complex and diverse biomass.
The Chinese Children and Families Cohort Study
Potischman, Nancy; Fang, Liwen; Hao, Ling; Bailey, Regan R.; Berrigan, David; Berry, Robert John; Brodie, Alison; Chao, Ann; Chen, Jing; Dodd, Kevin; Feng, Yajing; Ma, Guansheng; He, Yuna; Fan, Jing; Kimlin, Michael; Kitahara, Cari; Linet, Martha; Li, Zhu; Liu, Ailing; Liu, Yashan; Sampson, Joshua; Su, Joseph; Sun, Jiandong; Tasevska, Natasha; Yang, Lichen; Yang, Ruilan; Zhang, Qian; Wang, Ning; Wang, Linhong; Yu, Wang
2018-01-01
This article reports the study design, methodological issues and early results of a pilot study testing methods for collecting nutrition, physical activity, and ultraviolet (UV) radiation exposure data in a groundbreaking study in China. Epidemiological studies suggest that exposures across the entire life course, including in utero, early childhood, and adolescence, may be important in the etiology of adult cancers and other chronic diseases. The Chinese Children and Families Cohort Study intends to follow-up subjects from the 1993 to 1995 Community Intervention Program of folic acid supplementation for the prevention of neural tube defects. This cohort is unique in that only folic acid exposure during pregnancy varies between groups as other supplements were not available, and there were nutrient deficiencies in the populations. Prior to launching a large-scale follow-up effort, a pilot study was conducted to assess the feasibility of recontacting original study participants to collect extensive diet, physical activity, and UV radiation exposure data in this population. The pilot study included 92 mothers and 184 adolescent children aged 14 to 17 years from 1 urban and 1 rural Community Intervention Program site. Subjects completed a Food Frequency Questionnaire, a 3-day food record, a physical activity questionnaire, a 3-day sun exposure diary together with 3 days of personal UV dosimetry, and 7 days of pedometry measurements and provided blood, saliva, and toenail samples. Grip strength and body composition measurements were taken, and ambient solar UV radiation was monitored in both study sites. While most of the assessments were successful, future studies would likely require different dietary intake instruments. The purpose of this report is to describe the study design and methodological issues emerging from this pilot work relevant for the follow-up of this large birth cohort. PMID:29930434
The diverse applications of plasma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sharma, Mukul, E-mail: mukulsharma@acropolis.edu.in; Darwhekar, Gajanan, E-mail: gdarwhekar@acropolis.edu.in; Dubey, Shivani, E-mail: dubeyshivani08@rediffmail.com
Plasma being the fourth state of matter has always been an attraction for Physicists and Chemists. With the advent of time, plasma energy has been recognized in having widening horizons in the field of Biomedical Sciences. Plasma medicine can be subdivided into three main fields; Non-thermal atmospheric-pressure direct plasma for medical therapy; Plasma-assisted modification of bio-relevant surfaces and Plasma-based bio-decontamination and sterilization. The basis of the research is that as it has free carrier molecules, it has the ability to target specific cells and regulate functions like wound healing. Plasma does not harm healthy human cells but can kill bacteriamore » and possibly even cancer cells to help treat various diseases. Nosocomial infection control, prevention and containment of contagious diseases, disinfection of medical devices, surface treatment (heat and UV sensitive surfaces) are research of interest. Recent success in generating plasma at very low temperature ie. Cold plasma makes the therapy painless. It has the ability to activate cellular responses and important mechanisms in the body. They target specific molecules such as prothrombin for blood coagulation, cytokines for killing bacteria, and angiogenesis for tissue regeneration. Plasma has bactericidal, fungicidal and virucidal properties. Plasma technology has flourishing future in diverse fields like Textiles, Nanofabrication, Automotives, Waste management, Microbiology, Food Hygiene, Medical Science like Skin treatments, sterilisation of wounds, Hand disinfection, Dental treatments etc. Food hygiene using plasma can be achieved in disinfection of food containers, food surface disinfection, hygiene in food handling, preparation and packaging. Therefore Plasma is most promising field for budding Scientist for fluorishing research in Biological Sciences.« less
The diverse applications of plasma
NASA Astrophysics Data System (ADS)
Sharma, Mukul; Dubey, Shivani; Darwhekar, Gajanan; Jain, Sudhir Kumar
2015-07-01
Plasma being the fourth state of matter has always been an attraction for Physicists and Chemists. With the advent of time, plasma energy has been recognized in having widening horizons in the field of Biomedical Sciences. Plasma medicine can be subdivided into three main fields; Non-thermal atmospheric-pressure direct plasma for medical therapy; Plasma-assisted modification of bio-relevant surfaces and Plasma-based bio-decontamination and sterilization. The basis of the research is that as it has free carrier molecules, it has the ability to target specific cells and regulate functions like wound healing. Plasma does not harm healthy human cells but can kill bacteria and possibly even cancer cells to help treat various diseases. Nosocomial infection control, prevention and containment of contagious diseases, disinfection of medical devices, surface treatment (heat and UV sensitive surfaces) are research of interest. Recent success in generating plasma at very low temperature ie. Cold plasma makes the therapy painless. It has the ability to activate cellular responses and important mechanisms in the body. They target specific molecules such as prothrombin for blood coagulation, cytokines for killing bacteria, and angiogenesis for tissue regeneration. Plasma has bactericidal, fungicidal and virucidal properties. Plasma technology has flourishing future in diverse fields like Textiles, Nanofabrication, Automotives, Waste management, Microbiology, Food Hygiene, Medical Science like Skin treatments, sterilisation of wounds, Hand disinfection, Dental treatments etc. Food hygiene using plasma can be achieved in disinfection of food containers, food surface disinfection, hygiene in food handling, preparation and packaging. Therefore Plasma is most promising field for budding Scientist for fluorishing research in Biological Sciences.
Degradation of DEET and Caffeine under UV/Chlorine and Simulated Sunlight/Chlorine Conditions.
Sun, Peizhe; Lee, Wan-Ning; Zhang, Ruochun; Huang, Ching-Hua
2016-12-20
Photoactivation of aqueous chlorine could promote degradation of chlorine-resistant and photochemically stable chemicals accumulated in swimming pools. This study investigated the degradation of two such chemicals, N,N-diethyl-3-methylbenzamide (DEET) and caffeine, by low pressure ultraviolet (UV) light and simulated sunlight (SS) activated free chlorine (FC) in different water matrices. Both DEET and caffeine were rapidly degraded by UV/FC and SS/FC but exhibited different kinetic behaviors. The degradation of DEET followed pseudo-first-order kinetics, whereas the degradation of caffeine accelerated with reaction. Mechanistic study revealed that, under UV/FC, ·OH and Cl· were responsible for degradation of DEET, whereas ClO· related reactive species (ClOrrs), generated by the reaction between FC and ·OH/Cl·, played a major role in addition to ·OH and Cl· in degrading caffeine. Reaction rate constants of DEET and caffeine with the respective radical species were estimated. The imidazole moiety of caffeine was critical for the special reactivity with ClOrrs. Water matrix such as pH had a stronger impact on the UV/FC process than the SS/FC process. In saltwater matrix under UV/FC and SS/FC, the degradation of DEET was significantly inhibited, but the degradation of caffeine was much faster than that in nonsalty solutions. The interaction between Br - and Cl - may play an important role in the degradation of caffeine by UV/FC in saltwater. Reaction product analysis showed similar product patterns by UV/FC and SS/FC and minimal formation of chlorinated intermediates and disinfection byproducts.
This ongoing project involves the development, validation and pilot application of a multiplex immunoassay based on Luminex microsphere technology to measure salivary antibody responses to the potentially-waterborne pathogens, noroviruses (Norwalk, VA387 and VA207), rotaviruses, ...
Disinfection of secondary effluents by infiltration percolation.
Makni, H
2001-01-01
Among the most attractive applications of reclaimed wastewater are: irrigation of public parks, sports fields, golf courses and market gardening. These uses require advanced wastewater treatment including disinfection. According to WHO guidelines (1989) and current rules and regulations in Tunisia, faecal coliform levels have to be reduced to < 10(3) or 10(2) CFU/100 mL. In Tunisia, most wastewater plants are only secondary treatment and, in order to meet health related regulations, the effluents need to be disinfected. However, it is usual for secondary effluents to need filtration prior to disinfection. Effectiveness of conventional disinfection processes, such as chlorination and UV radiation, are dependent upon the oxidation level and the levels of suspended solids of the treated water. Ozonation is relatively expensive and energy consuming. The consideration of the advantages and disadvantages of conventional techniques, their reliability, investment needs and operational costs will lead to the use of less sophisticated alternative techniques for certain facilities. Among alternative techniques, soil aquifer treatment and infiltration percolation through sand beds have been studied in Arizona, Israel, France, Spain and Morocco. Infiltration percolation plants have been intermittently fed with secondary or high quality primary effluents which percolated through 1.5-2 m unsaturated coarse sand and were recovered by under-drains. In such infiltration percolation facilities, microorganisms were eliminated through numerous physical, physicochemical and biological inter-related processes (mechanical filtration, adsorption and microbial degradation respectively). Efficiency of faecal coliform removal was dependent upon the water detention times in the filtering medium and on the oxidation of the filtered water. Effluents of Sfax town aerated ponds were infiltrated through 1.5 m deep sand columns in order to determine the performance of infiltration percolation in the polishing of secondary effluents. Elimination of bacteria (total and coliforms, faecal streptococci) and their relationship with the hydraulic load and the temperature were investigated.
U.S. EPA’s Office of Research and Development in Cincinnati, Ohio has been testing and evaluating MTBE removal in dechlorinated tap water using three oxidant combinations: hydrogen peroxide/ozone, ultraviolet irradiation (UV)/ozone, and UV/ozone/hydrogen peroxide. Pilot-scale st...
Development of a molecular method for testing the effectiveness of UV systems on-site.
Nizri, Limor; Vaizel-Ohayon, Dalit; Ben-Amram, Hila; Sharaby, Yehonatan; Halpern, Malka; Mamane, Hadas
2017-12-15
We established a molecular method for quantifying ultraviolet (UV) disinfection efficacy using total bacterial DNA in a water sample. To evaluate UV damage to the DNA, we developed the "DNA damage" factor, which is a novel cultivation-independent approach that reveals UV-exposure efficiency by applying a simple PCR amplification method. The study's goal was to prove the feasibility of this method for demonstrating the efficiency of UV systems in the field using flow-through UV reactors. In laboratory-based experiments using seeded bacteria, the DNA damage tests demonstrated a good correlation between PCR products and UV dose. In the field, natural groundwater sampled before and after being subjected to the full-scale UV reactors was filtered, and the DNA extracted from the filtrate was subjected to PCR amplification for a 900-bp fragment of the 16S rRNA gene with initial DNA concentrations of 0.1 and 1 ng/μL. In both cases, the UV dose predicted and explained a significant proportion of the variance in the log inactivation ratio and DNA damage factor. Log inactivation ratio was very low, as expected in groundwater due to low initial bacterial counts, whereas the DNA damage factor was within the range of values obtained in the laboratory-based experiments. Consequently, the DNA damage factor reflected the true performance of the full-scale UV system during operational water flow by using the indigenous bacterial array present in a water sample. By applying this method, we were able to predict with high confidence, the UV reactor inactivation potential. For method validation, laboratory and field iterations are required to create a practical field calibration curve that can be used to determine the expected efficiency of the full-scale UV system in the field under actual operation. Copyright © 2017 Elsevier Ltd. All rights reserved.
Schmidt, Carsten K; Brauch, Heinz-Jürgen
2008-09-01
Application and microbial degradation of the fungicide tolylfluanide gives rise to a new decomposition product named N,N-dimethylsulfamide (DMS). In Germany, DMS was found in groundwaters and surface waters with typical concentrations in the range of 100-1000 ng/L and 50-90 ng/L, respectively. Laboratory-scale and field investigations concerning its fate during drinking water treatment showed that DMS cannot be removed via riverbank filtration, activated carbon filtration, flocculation, and oxidation or disinfection procedures based on hydrogen peroxide, potassium permanganate, chlorine dioxide, or UV irradiation. Even nanofiltration does not provide a sufficient removal efficiency. During ozonation about 30-50% of DMS are converted to the carcinogenic N-nitrosodimethylamine (NDMA). The NDMA being formed is biodegradable and can at least partially be removed by subsequent biologically active drinking water treatment steps including sand or activated carbon filtration. Disinfection with hypochlorous acid converts DMS to so far unknown degradation products but not to NDMA or 1,1-dimethylhydrazine (UDMH).
Fackrell, Joseph K; Glenn, Craig R; Popp, Brian N; Whittier, Robert B; Dulai, Henrietta
2016-09-15
We utilize N and C species concentration data along with δ(15)N values of NO3(-) and δ(13)C values of dissolved inorganic C to evaluate the stoichiometry of biogeochemical reactions (mineralization, nitrification, anammox, and denitrification) occurring within a subsurface wastewater plume that originates as treated wastewater injection and enters the coastal waters of Maui as submarine groundwater discharge. Additionally, we compare wastewater effluent time-series data, injection rates, and treatment history with submarine spring discharge time-series data. We find that heterotrophic denitrification is the primary mechanism of N loss within the groundwater plume and that chlorination for pathogen disinfection suppresses microbial activity in the aquifer responsible for N loss, resulting in increased coastal ocean N loading. Replacement of chlorination with UV disinfection may restore biogeochemical reactions responsible for N loss within the aquifer and return N-attenuating conditions in the effluent plume, reducing N loading to coastal waters. Copyright © 2016 Elsevier Ltd. All rights reserved.
Shin, Joo-Yeon; Kim, Soo-Ji; Kim, Do-Kyun
2015-01-01
Low-pressure mercury UV (LP-UV) lamps have long been used for bacterial inactivation, but due to certain disadvantages, such as the possibility of mercury leakage, deep-UV-C light-emitting diodes (DUV-LEDs) for disinfection have recently been of great interest as an alternative. Therefore, in this study, we examined the basic spectral properties of DUV-LEDs and the effects of UV-C irradiation for inactivating foodborne pathogens, including Escherichia coli O157:H7, Salmonella enterica serovar Typhimurium, and Listeria monocytogenes, on solid media, as well as in water. As the temperature increased, DUV-LED light intensity decreased slightly, whereas LP-UV lamps showed increasing intensity until they reached a peak at around 30°C. As the irradiation dosage and temperature increased, E. coli O157:H7 and S. Typhimurium experienced 5- to 6-log-unit reductions. L. monocytogenes was reduced by over 5 log units at a dose of 1.67 mJ/cm2. At 90% relative humidity (RH), only E. coli O157:H7 experienced inactivation significantly greater than at 30 and 60% RH. In a water treatment study involving a continuous system, 6.38-, 5.81-, and 3.47-log-unit reductions were achieved in E. coli O157:H7, S. Typhimurium, and L. monocytogenes, respectively, at 0.5 liter per minute (LPM) and 200 mW output power. The results of this study suggest that the use of DUV-LEDs may compensate for the drawbacks of using LP-UV lamps to inactivate foodborne pathogens. PMID:26162872
Čehovin, Matej; Medic, Alojz; Scheideler, Jens; Mielcke, Jörg; Ried, Achim; Kompare, Boris; Žgajnar Gotvajn, Andreja
2017-07-01
Natural organic matter in drinking water is causing concern especially due to the formation of disinfection by-products (DBPs) by chlorine, as these are proven to have adverse health effects on consumers. In this research, humic acid was used as a source of dissolved organic carbon (DOC) in drinking water (up to 3mgL -1 ). The efficiency of DOC removal was studied by applying O 3 , H 2 O 2 /O 3 , H 2 O 2 /UV and O 3 /UV advanced oxidation processes (AOPs) alone and combined with hybrid hydrodynamic cavitation (HC), generated by an orifice plate, as this technology recently shows promising potential for the treatment of water, containing recalcitrant organic substances. It was observed that the combined treatment by HC could significantly affect the performance of the applied AOPs, with as little as 3-9 passes through the cavitation generators. For O 3 and H 2 O 2 dosages up to 2 and 4mgL -1 , respectively, and UV dosage up to 300mJcm -2 , HC enhanced DOC removal by 5-15% in all combinations, except for O 3 /UV AOPs. Overall, the potential benefits of HC for DOC removal were emphasized for low ratio between applied oxidants to DOC and high UV absorbance of the sample. Investigated DBPs formation potentials require special attention for H 2 O 2 /UV AOPs and combinations with HC. Copyright © 2017 Elsevier B.V. All rights reserved.
Huang, Jing-Jing; Xi, Jinying; Hu, Hong-Ying; Li, Yi; Lu, Sun-Qin; Tang, Fang; Pang, Yu-Chen
2016-03-01
Tetracycline-resistant bacteria (TRB) are of concern as emerging microbial contaminants in reclaimed water. To understand the effects of UV disinfection on TRB, both inactivation and reactivation profiles of TRB, as well as 16 tetracycline-resistant isolates from secondary effluent, were characterized in this study. The inactivation ratio of TRB was significantly lower (3.0-log) than that of heterotrophic bacteria (>4.0-log) in the secondary effluent. Additionally, the proportion of TRB significantly increased from 1.65% to 15.51% under 20mJ/cm(2) ultraviolet (UV) exposure. The inactivation rates of tetracycline-resistant isolates ranged from 0.57/s to 1.04/s, of which tetracycline-resistant Enterobacter-1 was the most tolerant to UV light. The reactivation of TRB, tetracycline-resistant isolated strains, as well as heterotrophic bacteria commonly occurred in the secondary effluent even after 20mJ/cm(2) UV exposure. The colony forming ability of TRB and heterotrophic bacteria reached 3.2-log and 3.0-log under 20mJ/cm(2) UV exposure after 22hr incubation. The final inactivation ratio of tetracycline-resistant Enterobacter-1 was 1.18-log under 20mJ/cm(2) UV exposure after 22hr incubation, which is similar to those of TRB (1.18-log) and heterotrophic bacteria (1.19-log). The increased proportion of TRB and the reactivation of tetracycline-resistant enterobacteria in reclaimed water could induce a microbial health risk during wastewater reuse. Copyright © 2015. Published by Elsevier B.V.
Evaluation of empirical process design relationships for ozone disinfection of water and wastewater
DOE Office of Scientific and Technical Information (OSTI.GOV)
Finch, G.R.; Smith, D.W.
A research program was undertaken to examine the dose-response of Escherichia coli ATCC 11775 in ozone demand-free phosphate buffer solution and in a high quality secondary wastewater effluent with a total organic carbon content of 8 mg/L and a chemical oxygen demand of 26 mg/L. The studies were conducted in bench-scale batch reactors for both water types. In addition, studies using secondary effluent also were conducted in a pilot-scale, semi-batch reactor to evaluate scale-up effects. It was found that the ozone dose was the most important design parameter in both types of water. Contact time was of some importance inmore » the ozone demand-free water and had no detectable effect in the secondary effluent. Pilot-scale data confirmed the results obtained at bench-scale for the secondary effluent. Regression analysis of the logarithm of the E. coli response on the logarithm of the utilized ozone dose revealed that there was lack-of-fit using the model form which has been used frequently for the design of wastewater disinfection systems. This occurred as a result of a marked tailing effect of the log-log plot as the ozone dose increased and the kill increased. It was postulated that this was caused by some unknown physiological differences within the E. coli population due to age or another factor.« less
Blatchley, E R; Shen, C; Scheible, O K; Robinson, J P; Ragheb, K; Bergstrom, D E; Rokjer, D
2008-02-01
Dyed microspheres have been developed as a new method for validation of ultraviolet (UV) reactor systems. When properly applied, dyed microspheres allow measurement of the UV dose distribution delivered by a photochemical reactor for a given operating condition. Prior to this research, dyed microspheres had only been applied to a bench-scale UV reactor. The goal of this research was to extend the application of dyed microspheres to large-scale reactors. Dyed microsphere tests were conducted on two prototype large-scale UV reactors at the UV Validation and Research Center of New York (UV Center) in Johnstown, NY. All microsphere tests were conducted under conditions that had been used previously in biodosimetry experiments involving two challenge bacteriophage: MS2 and Qbeta. Numerical simulations based on computational fluid dynamics and irradiance field modeling were also performed for the same set of operating conditions used in the microspheres assays. Microsphere tests on the first reactor illustrated difficulties in sample collection and discrimination of microspheres against ambient particles. Changes in sample collection and work-up were implemented in tests conducted on the second reactor that allowed for improvements in microsphere capture and discrimination against the background. Under these conditions, estimates of the UV dose distribution from the microspheres assay were consistent with numerical simulations and the results of biodosimetry, using both challenge organisms. The combined application of dyed microspheres, biodosimetry, and numerical simulation offers the potential to provide a more in-depth description of reactor performance than any of these methods individually, or in combination. This approach also has the potential to substantially reduce uncertainties in reactor validation, thereby leading to better understanding of reactor performance, improvements in reactor design, and decreases in reactor capital and operating costs.
Li, Mengkai; Li, Wentao; Qiang, Zhimin; Blatchley, Ernest R
2017-07-18
At present, on-site fluence (distribution) determination and monitoring of an operating UV system represent a considerable challenge. The recently developed microfluorescent silica detector (MFSD) is able to measure the approximate true fluence rate (FR) at a fixed position in a UV reactor that can be compared with a FR model directly. Hence it has provided a connection between model calculation and real-time fluence determination. In this study, an on-site determination and monitoring method of fluence delivery for an operating UV reactor was developed. True FR detectors, a UV transmittance (UVT) meter, and a flow rate meter were used for fundamental measurements. The fluence distribution, as well as reduction equivalent fluence (REF), 10th percentile dose in the UV fluence distribution (F 10 ), minimum fluence (F min ), and mean fluence (F mean ) of a test reactor, was calculated in advance by the combined use of computational fluid dynamics and FR field modeling. A field test was carried out on the test reactor for disinfection of a secondary water supply. The estimated real-time REF, F 10 , F min , and F mean decreased 73.6%, 71.4%, 69.6%, and 72.9%, respectively, during a 6-month period, which was attributable to lamp output attenuation and sleeve fouling. The results were analyzed with synchronous data from a previously developed triparameter UV monitoring system and water temperature sensor. This study allowed demonstration of an accurate method for on-site, real-time fluence determination which could be used to enhance the security and public confidence of UV-based water treatment processes.
NASA Astrophysics Data System (ADS)
Bhatti, Zulfiqar Ahmed; Mahmood, Qaisar; Raja, Iftikhar Ahmad; Malik, Amir Haider; Rashid, Naim; Wu, Donglei
Dilemmas like water shortage, rapid industrialization, growing human population and related issues have seriously affected human health and environmental sustainability. For conservation and sustainable use of our water resources, innovative methods for wastewater treatment are continuously being explored. Advance Oxidation Processes (AOPs) show a promising approach to meet specific objectives of municipal wastewater treatment (MWW). The MWW samples were pretreated with Al 2(SO 4) 4·8H 2O (Alum) at different doses 4, 8, 12-50 mg/L to enhance the sedimentation. The maximum COD removal was observed at alum treatments in range of 28-32 mg/L without increasing total dissolved solids (TDS). TDS were found to increase when the alum dose was increased from 32-40 mg/L. In the present study, the optimum alum dose of 30 mg/L for 3 h of sedimentation and subsequent integrated H 2O 2/UV treatment was applied (using 2.5 mL/L of 40% waste H 2O 2 and 35% fresh H 2O 2 separately). Organic and inorganic pollutants, contributing towards chemical oxygen demand (COD), biological oxygen demand (BOD), turbidity and total dissolved solids were degraded by H 2O 2/UV. About 93% COD, 90% BOD and 83% turbidity reduction occurred when 40% waste H 2O 2 was used. When using fresh H 2O 2, 63% COD, 68% BOD and 86% turbidity reduction was detected. Complete disinfection of coliform bacteria occurred by using 40% H 2O 2/UV. The most interesting part of this research was to compare the effectiveness of waste H 2O 2 with fresh H 2O 2. Waste H 2O 2 generated from an industrial process of disinfection was found more effective in the treatment of MWW than fresh 35% H 2O 2.
Narciso-da-Rocha, Carlos; Rocha, Jaqueline; Vaz-Moreira, Ivone; Lira, Felipe; Tamames, Javier; Henriques, Isabel; Martinez, José Luis; Manaia, Célia M
2018-06-05
Urban wastewater treatment plants (UWTPs) are reservoirs of antibiotic resistance. Wastewater treatment changes the bacterial community and inevitably impacts the fate of antibiotic resistant bacteria and antibiotic resistance genes (ARGs). Some bacterial groups are major carriers of ARGs and hence, their elimination during wastewater treatment may contribute to increasing resistance removal efficiency. This study, conducted at a full-scale UWTP, evaluated variations in the bacterial community and ARGs loads and explored possible associations among them. With that aim, the bacterial community composition (16S rRNA gene Illumina sequencing) and ARGs abundance (real-time PCR) were characterized in samples of raw wastewater (RWW), secondary effluent (sTWW), after UV disinfection (tTWW), and after a period of 3 days storage to monitoring possible bacterial regrowth (tTWW-RE). Culturable enterobacteria were also enumerated. Secondary treatment was associated with the most dramatic bacterial community variations and coincided with reductions of ~2 log-units in the ARGs abundance. In contrast, no significant changes in the bacterial community composition and ARGs abundance were observed after UV disinfection of sTWW. Nevertheless, after UV treatment, viability losses were indicated ~2 log-units reductions of culturable enterobacteria. The analysed ARGs (qnrS, bla CTX-M , bla OXA-A , bla TEM , bla SHV , sul1, sul2, and intI1) were strongly correlated with taxa more abundant in RWW than in the other types of water, and which associated with humans and animals, such as members of the families Campylobacteraceae, Comamonadaceae, Aeromonadaceae, Moraxellaceae, and Bacteroidaceae. Further knowledge of the dynamics of the bacterial community during wastewater treatment and its relationship with ARGs variations may contribute with information useful for wastewater treatment optimization, aiming at a more effective resistance control. Copyright © 2018 Elsevier Ltd. All rights reserved.
Hua, Lap-Cuong; Lin, Jr-Lin; Syue, Ming-Yang; Huang, Chihpin; Chen, Pei-Chung
2018-04-15
Algogenic organic matter (AOM) in eutrophic waters is a well-known precursor to disinfection by-product (DBP) formation in drinking water. This purpose of this study is (i) to characterize the optical properties of AOM origins, including intra- (IOM) and extra-cellular organic matter (EOM), derived from Chlorella sp. growth as precursors to two major carbonaceous DBPs (C-DBPs), trihalomethanes (THMs) and haloacetic acids (HAAs) and (ii) to correlate these optical properties with THM and HAA formation potential (FP) in order to predict DBP formation. The results show that both EOM and IOM had low UV 254 and UV 280 absorbance during their entire growth phase. While IOM chiefly comprised of aromatic proteins and soluble microbial products-like substances (80% of average fluorescent intensity-AFI), EOM spectra were rich in humic- and fulvic-like substances (60% AFI). However, its chemical nature likely differed from terrestrial humics. In DBPFP tests, IOM was a higher-yielding precursor of THMs and HAAs compared to EOM, regardless its growth status. Consequently, C-DBPFP of IOM was always higher than EOM during four growth phases. Results from DBP tests also showed insignificant variation of EOM-derived THMFP and HAAFP during the algal growth phase, while the algal growth status strongly influenced the yields of IOM-derived THMFP and HAAFP. From correlation analysis, our results showed no correlation between UV absorbance with THMFP and HAAFP. Conversely, the regional AFI showed a good correlation with HAAFP and C-DBPFP. Predicting models based on AFI for the formation of HAAs and C-DBPs consequently yielded great predictability for laboratory AOM-containing water samples, with a coefficient of determination R 2 =0.879, p<0.01 and R 2 =0.846, p<0.01. This study indicates a promising application of fluorescent spectra for predicting DBPs derived from algae-rich water sources. Copyright © 2017 Elsevier B.V. All rights reserved.
Photocatalytic degradation of 17α-ethinylestradiol (EE2) in the presence of TiO2-doped zeolite.
Pan, Zhong; Stemmler, Elizabeth A; Cho, Hong Je; Fan, Wei; LeBlanc, Lawrence A; Patterson, Howard H; Amirbahman, Aria
2014-08-30
Current design limitations and ineffective remediation techniques in wastewater treatment plants have led to concerns about the prevalence of pharmaceutical and personal care products (PPCPs) in receiving waters. A novel photocatalyst, TiO2-doped low-silica X zeolite (TiO2-LSX), was used to study the degradation of the pharmaceutical compound, 17α-ethinylestradiol (EE2). The catalyst was synthesized and characterized using XRD, BET surface analysis, SEM-EDAX, and ICP-OES. The effects of different UV light intensities, initial EE2 concentrations, and catalyst dosages on the EE2 removal efficiency were studied. A higher EE2 removal efficiency was attained with UV-TiO2-LSX when compared with UV-TiO2 or UV alone. The EE2 degradation process followed pseudo-first-order kinetics. A comprehensive empirical model was developed to describe the EE2 degradation kinetics under different conditions using multiple linear regression analysis. The EE2 degradation mechanism was proposed based on molecular calculations, identification of photoproducts using HPLC-MS/MS, and reactive species quenching experiments; the results showed that oxidative degradation pathways initiated by hydroxyl radicals were predominant. This novel TiO2-doped zeolite system provides a promising application for the UV disinfection process in wastewater treatment plants. Copyright © 2014 Elsevier B.V. All rights reserved.
Amin, Muhammad Tahir; Han, Mooyoung
2009-01-01
Efficiency of solar disinfection (SODIS) was evaluated for the potability of rainwater in view of the increasing water and energy crises especially in developing countries. Rainwater samples were collected from an underground storage tank in 2 L polyethylene terephthalate (PET) bottles and SODIS efficiency was evaluated at different weather conditions. For optimizing SODIS, PET bottles with different backing surfaces to enhance the optical and thermal effects of SODIS were used and different physicochemical parameters were selected and evaluated along with microbial re-growth observations and calculating microbial decay constants. Total and fecal coliforms were used along with Escherichia Coli and Heterotrophic Plate Counts (HPC) as basic microbial and indicator organisms of water quality. For irradiance less than 600 W/m(2), reflective type PET bottles were best types while for radiations greater than 700 W/m(2), absorptive type PET bottles offered best solution due to the synergistic effects of both thermal and UV radiations. Microbial inactivation did not improve significantly by changing the initial pH and turbidity values but optimum SODIS efficiency is achieved for rainwater with acidic pH and low initial turbidity values by keeping air-spaced PET bottles in undisturbed conditions. Microbial re-growth occurred after one day only at higher turbidity values and with basic pH values. First-order reaction rate constant was in accordance with recent findings for TC but contradicted with previous researches for E. coli. No microbial parameter met drinking water guidelines even under strong experimental weather conditions rendering SODIS ineffective for complete disinfection and hence needed more exposure time or stronger sunlight radiations. With maximum possible storage of rainwater, however, and by using some means for accelerating SODIS process, rainwater can be disinfected and used for potable purposes.
1972-06-06
S72-40818 (21 April 1972) --- A color enhancement of an ultra-violet photograph of the geocorona, a halo of low density hydrogen around Earth. Sunlight is shining from the left, and the geocorona is brighter on that side. The UV camera was operated by astronaut John W. Young on the Apollo 16 lunar landing mission. It was designed and built at the Naval Research Laboratory, Washington, D.C. While astronauts Young, commander, and Charles M. Duke Jr., lunar module pilot, descended in the Lunar Module (LM) "Orion" to explore the Descartes highlands region of the moon, astronaut Thomas K. Mattingly II, command module pilot, remained with the Command and Service Modules (CSM) "Casper" in lunar orbit.
Mutagenic activity of disinfection by-products
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cognet, L.; Courtois, Y.; Mallevialle, J.
1986-11-01
Data on raw water quality, disinfection treatment practices, and the resulting mutagenic properties of the treated water were compiled from pilot- and full-scale treatment experiments to evaluate that parameter which might produce variability in the results of a mutagenic study. Analysis of the data and comparison of treatment practices indicated that the measured mutagenic activity is strongly related to the characteristics of the organic matter in the raw water, the methodology used to sample and detect mutagens, the scale of the study both in terms of treatment flow and period of study, and the point at which and the conditionsmore » under which oxidants are added during treatment. Conclusions regarding disinfection systems in full-scale water treatment plants include the following: When raw water is pretreated and high concentrations of organics are present in the raw water, both ozonation and chlorination increased mutagenic activity. However, no significant difference in mutagenicity was found between the two oxidants. Both in the case of a nitrified groundwater and a clarified surface water, the mutagenic activity of the water after ozonation was related to its mutagenic activity before ozonation. With ozonation, mutagenic activity decreased after granular activated carbon (GAC) filtration. Thus, when GAC filtration follows ozone disinfection, early addition of oxidants may not be deleterious to the finished water quality. When chlorine or chlorine dioxide is added after GAC filtration, chlorine dioxide was found to produce a less mutagenic water than chlorine. Although these conclusions suggest means of controlling mutagenic activity during treatment, it must be stressed that the measurement of mutagenicity is a presumptive index of contamination level.« less
Qian-Yuan, Wu; Chao, Li; Ye, Du; Wen-Long, Wang; Huang, Huang; Hong-Ying, Hu
2016-05-15
Ecological storage of reclaimed water in ponds and lakes is widely applied in water reuse. During reclaimed water storage, solar light can degrade pollutants and improve water quality. This study investigated the effects of solar light irradiation on the disinfection byproduct formation potential in reclaimed water, including haloacetonitriles (HANs), trichloronitromethane (TCNM), trihalomethanes (THMs), haloketones (HKs) and chloral hydrate (CH). Natural solar light significantly decreased the formation potential of HANs, TCNM, and HKs in reclaimed water, but had a limited effect on the formation potential of THMs and CH. Ultraviolet (UV) light in solar radiation played a dominant role in the decrease of the formation potential of HANs, TCNM and HKs. Among the disinfection byproducts, the removal kinetic constant of dichloroacetonitrile (DCAN) with irradiation dose was much larger than those for dichloropropanone (1,1-DCP), trichloropropanone (1,1,1-TCP) and TCNM. During solar irradiation, fluorescence spectra intensities of reclaimed water also decreased significantly. The removal of tyrosine (Tyr)-like and tryptophan (Trp)-like protein fluorescence spectra intensity volumes was correlated to the decrease in DCAN formation potential. Solar irradiation was demonstrated to degrade Trp, Tyr and their DCAN formation potential. The photolysis products of Trp after solar irradiation were detected as kynurenine and tryptamine, which had chloroform, CH and DCAN formation potential lower than those of Trp. Copyright © 2016. Published by Elsevier Ltd.
Bak, Jimmy; Jørgensen, Thomas M; Helfmann, Jurgen; Gravemann, Ute; Vorontsova, Inessa
2011-01-01
We have demonstrated that it is possible to launch UVC LED light into bacterial contaminated polymer tubes/catheters and disinfect the intraluminal space of these tubes. This can be achieved by UVC treatment of the catheters on a regular basis. Catheters are in the distal end equipped with an exit hole for administration of drugs, bloods or nutrients into the bloodstream. Even if the UVC light is strongly attenuated during its propagation through the catheter tube a fraction of the UVC launched into the catheter will escape through the exit hole and irradiate the blood. We demonstrate by calculations that very small effective doses are exposed to the blood (ca 10(-4) J m(-2)). This dosage level is very low compared with UVC doses reported from other therapeutic applications. The very short residence time of the blood constituents in the irradiated volume in front of the exit hole is the main reason why the UVC exposure to the blood in the catheter application is so low. The very low dose received by the blood through the catheter tip indicated that possible side effects are negligible and makes the UV disinfection technique feasible in a clinical setting. © 2011 Jimmy Bak. Photochemistry and Photobiology © 2011 The American Society of Photobiology.
Davies, A; Pottage, T; Bennett, A; Walker, J
2011-03-01
The recent data for hospital-acquired infections suggest that infection rates for meticillin-resistant Staphylococcus aureus (MRSA) and Clostridium difficile are beginning to decrease. However, while there is still pressure to maintain this trend, the resistance of C. difficile spores to standard detergents continues to present a problem for many UK hospitals trying to prevent its spread or control outbreaks. Alternative disinfection technologies such as gaseous decontamination are currently being marketed to the healthcare sector as an alternative/supplement to manual disinfection, and have been shown to be effective in reducing environmental contamination. When used correctly, they offer a complementary technology to manual cleaning that increases the probability of an effective reduction in viability and provides a comparatively uniform distribution of disinfectant. Three gaseous decontamination technologies are examined for their suitability in reducing environmental contamination with C. difficile: gaseous hydrogen peroxide, chlorine dioxide and ozone. Air decontamination and UV-based technologies are also briefly described. We conclude that while there is a role to play for these new technologies in the decontamination of ward surfaces contaminated with C. difficile, the requirement for both a preclean before use and the limited 'in vivo' evidence means that extensive field trials are necessary to determine their cost-effectiveness in a healthcare setting. Copyright © 2010 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.
Giannakis, Stefanos; Voumard, Margaux; Grandjean, Dominique; Magnet, Anoys; De Alencastro, Luiz Felippe; Pulgarin, César
2016-10-01
In this work, disinfection by 5 Advanced Oxidation Processes was preceded by 3 different secondary treatment systems present in the wastewater treatment plant of Vidy, Lausanne (Switzerland). 5 AOPs after two biological treatment methods (conventional activated sludge and moving bed bioreactor) and a physiochemical process (coagulation-flocculation) were tested in laboratory scale. The dependence among AOPs efficiency and secondary (pre)treatment was estimated by following the bacterial concentration i) before secondary treatment, ii) after the different secondary treatment methods and iii) after the various AOPs. Disinfection and post-treatment bacterial regrowth were the evaluation indicators. The order of efficiency was Moving Bed Bioreactor > Activated Sludge > Coagulation-Flocculation > Primary Treatment. As far as the different AOPs are concerned, the disinfection kinetics were: UVC/H2O2 > UVC and solar photo-Fenton > Fenton or solar light. The contextualization and parallel study of microorganisms with the micropollutants of the effluents revealed that higher exposure times were necessary for complete degradation compared to microorganisms for the UV-based processes and inversed for the Fenton-related ones. Nevertheless, in the Fenton-related systems, the nominal 80% removal of micropollutants deriving from the Swiss legislation, often took place before the elimination of bacterial regrowth risk. Copyright © 2016 Elsevier Ltd. All rights reserved.
Jing, Liang; Chen, Bing; Wen, Diya; Zheng, Jisi; Zhang, Baiyu
2017-12-01
This study shed light on removing atrazine from pesticide production wastewater using a pilot-scale UV/O 3 /ultrasound flow-through system. A significant quadratic polynomial prediction model with an adjusted R 2 of 0.90 was obtained from central composite design with response surface methodology. The optimal atrazine removal rate (97.68%) was obtained at the conditions of 75 W UV power, 10.75 g h -1 O 3 flow rate and 142.5 W ultrasound power. A Monte Carlo simulation aided artificial neural networks model was further developed to quantify the importance of O 3 flow rate (40%), UV power (30%) and ultrasound power (30%). Their individual and interaction effects were also discussed in terms of reaction kinetics. UV and ultrasound could both enhance the decomposition of O 3 and promote hydroxyl radical (OH·) formation. Nonetheless, the dose of O 3 was the dominant factor and must be optimized because excess O 3 can react with OH·, thereby reducing the rate of atrazine degradation. The presence of other organic compounds in the background matrix appreciably inhibited the degradation of atrazine, while the effects of Cl - , CO 3 2- and HCO 3 - were comparatively negligible. It was concluded that the optimization of system performance using response surface methodology and neural networks would be beneficial for scaling up the treatment by UV/O 3 /ultrasound at industrial level. Copyright © 2017 Elsevier Ltd. All rights reserved.
Uhl, W; Hartmann, C
2005-01-01
For swimming pools, it is generally agreed that free chlorine levels have to be maintained to guarantee adequate disinfection. Recommended free chlorine levels can vary between 0.3 and 0.6 mg/L in Germany and up to 3 mg/L in other countries. Bathers introduce considerable amounts of organic matter, mainly in the form of such as urine and sweat, into the pool water. As a consequence, disinfection byproducts (DBPs) are formed. Regulations in Germany recommend levels of combined chlorine of less than 0.2 mg/L and levels of trihalomethanes (THMs) of less than 20 microg/L. Haloacetic acids (HAAs), haloacetonitriles (HANs), chloropicrin and chloral hydrate are also detected in considerable amounts. However, these compounds are not regulated yet. Swimming pool staff and swimmers, especially athletes, are primarily exposed to these byproducts by inhalation and/or dermal uptake. In Germany, new regulations for swimming pool water treatment generally require the use of activated carbon. In this project, three different types of granular activated carbon (GAC) (one standard GAC, two catalytic GACs) are compared for their long time behaviour in pool water treatment. In a pilot plant operated with real swimming pool water, production and removal of disinfection byproducts (THMs, HAAs, AOXs), of biodegradable substances (AOC), of bacteria (Pseudomonas aeruginosa, Legionella, coliforms, HPC) as well as the removal of chlorine and chloramines are monitored as function of GAC bed depth. Combined chlorine penetrates deeper in the filter bed than free chlorine does. However, both, free and combined chlorine removal efficiencies decrease over the time of filter operation. The decreases of removal efficiencies are also observed for parameters such as dissolved organic carbon, spectral absorption coefficient, adsorbable organic carbon and most of the disinfection byproducts. However, THMs, especially chloroform are produced in the filter bed. The GAC beds were contaminated microbially, especially with P. aeruginosa. The contamination was not removable by backwashing with chlorine concentrations up to 2 mg/l free chlorine.
Quinot, Catherine; Amsellem-Dubourget, Sylvie; Temam, Sofia; Sevin, Etienne; Barreto, Christine; Tackin, Arzu; Félicité, Jérémy; Lyon-Caen, Sarah; Siroux, Valérie; Girard, Raphaële; Descatha, Alexis; Le Moual, Nicole; Dumas, Orianne
2018-05-14
Healthcare workers are highly exposed to various types of disinfectants and cleaning products. Assessment of exposure to these products remains a challenge. We aimed to investigate the feasibility of a method, based on a smartphone application and bar codes, to improve occupational exposure assessment among hospital/cleaning workers in epidemiological studies. A database of disinfectants and cleaning products used in French hospitals, including their names, bar codes and composition, was developed using several sources: ProdHyBase (a database of disinfectants managed by hospital hygiene experts), and specific regulatory agencies and industrial websites. A smartphone application has been created to scan bar codes of products and fill a short questionnaire. The application was tested in a French hospital. The ease of use and the ability to record information through this new approach were estimated. The method was tested in a French hospital (7 units, 14 participants). Through the application, 126 records (one record referred to one product entered by one participant/unit) were registered, majority of which were liquids (55.5%) or sprays (23.8%); 20.6% were used to clean surfaces and 15.9% to clean toilets. Workers used mostly products with alcohol and quaternary ammonium compounds (>90% with weekly use), followed by hypochlorite bleach and hydrogen peroxide (28.6%). For most records, information was available on the name (93.7%) and bar code (77.0%). Information on product compounds was available for all products and recorded in the database. This innovative and easy-to-use method could help to improve the assessment of occupational exposure to disinfectants/cleaning products in epidemiological studies. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Szabo, Jeffrey G; Meiners, Greg; Heckman, Lee; Rice, Eugene W; Hall, John
2017-02-01
Decontamination of Bacillus spores adhered to common drinking water infrastructure surfaces was evaluated using a variety of disinfectants. Corroded iron and cement-mortar lined iron represented the infrastructure surfaces, and were conditioned in a 23 m long, 15 cm diameter (75 ft long, 6 in diameter) pilot-scale drinking water distribution pipe system. Decontamination was evaluated using increased water velocity (flushing) alone at 0.5 m s -1 (1.7 ft s -1 ), as well as free chlorine (5 and 25 mg L -1 ), monochloramine (25 mg L -1 ), chlorine dioxide (5 and 25 mg L -1 ), ozone (2.0 mg L -1 ), peracetic acid 25 mg L -1 ) and acidified nitrite (0.1 mol L -1 at pH 2 and 3), all followed by flushing at 0.3 m s -1 (1 ft s -1 ). Flushing alone reduced the adhered spores by 0.5 and 2.0 log 10 from iron and cement-mortar, respectively. Log 10 reduction on corroded iron pipe wall coupons ranged from 1.0 to 2.9 at respective chlorine dioxide concentrations of 5 and 25 mg L -1 , although spores were undetectable on the iron surface during disinfection at 25 mg L -1 . Acidified nitrite (pH 2, 0.1 mol L -1 ) yielded no detectable spores on the iron surface during the flushing phase after disinfection. Chlorine dioxide was the best performing disinfectant with >3.0 log 10 removal from cement-mortar at 5 and 25 mg L -1 . The data show that free chlorine, monochloramine, ozone and chlorine dioxide followed by flushing can reduce adhered spores by > 3.0 log 10 on cement-mortar. Published by Elsevier Ltd.
UV-induced effects on chlorination of creatinine.
Weng, Shih Chi; Li, Jing; Wood, Karl V; Kenttämaa, Hilkka I; Williams, Peggy E; Amundson, Lucas M; Blatchley, Ernest R
2013-09-15
Ultraviolet (UV) irradiation is commonly employed for water treatment in swimming pools to complement conventional chlorination, and to reduce the concentration of inorganic chloramine compounds. The approach of combining UV irradiation and chlorination has the potential to improve water quality, as defined by microbial composition. However, relatively little is known about the effects of this process on water chemistry. To address this issue, experiments were conducted to examine the effects of sequential UV254 irradiation/chlorination, as will occur in recirculating system of swimming pools, on disinfection byproduct (DBP) formation. Creatinine, which is present in human sweat and urine, was selected as the target precursor for these experiments. Enhanced formation of dichloromethylamine (CH3NCl2) and inorganic chloramines was observed to result from post-chlorination of UV-irradiated samples. Chlorocreatinine was found to be more sensitive to UV254 irradiation than creatinine; UV254 irradiation of chlorocreatinine resulted in opening of the ring structure, thereby yielding a series of intermediates that were more susceptible to free chlorine attack than their parent compound. The quantum yields for photodegradation of creatinine and chlorocreatinine at 254 nm were estimated at 0.011 ± 0.002 mol/E and 0.144 ± 0.011 mol/E, respectively. The N-Cl bond was found to be common to UV-sensitive chlorinated compounds (e.g., inorganic chloramines, CH3NCl2, and chlorocreatinine); compounds that were less susceptible to UV-based attack generally lacked the N-Cl bond. This suggested that the N-Cl bond is susceptible to UV254 irradiation, and cleavage of the N-Cl bond appears to open or promote reaction pathways that involve free chlorine, thereby enhancing formation of some DBPs and promoting loss of free chlorine. Proposed reaction mechanisms to describe this behavior based on creatinine as a precursor are presented. Copyright © 2013 Elsevier Ltd. All rights reserved.
Ha, Ji-Hyoung; Ha, Sang-Do
2011-05-01
The purpose of this study was to determine whether combined treatment would produce synergistic effects to facilitate the sterilization of food products during production relative to single treatment. To assess this hypothesis, we investigated the bactericidal effects of ultraviolet (UV) irradiation and a commercial chemical disinfectant, sodium hypochlorite (NaClO), on Bacillus cereus F4810/72, Cronobacter sakazakii KCTC 2949, Staphylococcus aureus ATCC 35556, Escherichia coli ATCC 10536, and Salmonella Typhimurium novobiocin/nalidixic acid in vitro. Various concentrations of NaClO (20, 60, 100, and 200 ppm NaClO) were tested along with exposure to UV radiation at various doses (6, 96, 216, 360, and 504 mW s/cm(2)). The combined NaClO/UV treatments resulted in greater reductions in bacterial counts than either treatment alone. The synergy values against B. cereus, C. sakazakii, S. aureus, Salmonella Typhimurium, and E. coli were 0.25-1.17, 0.33-1.97, 0.42-1.72, 0.02-1.44, and 0.01-0.85 log(10) CFU/mL, respectively. The results of this study suggest that a significant synergistic benefit results from combined NaClO/UV processing against food-borne pathogenic bacteria in vitro.
Zhou, Dandan; Xu, Zhengxue; Dong, Shanshan; Huo, Mingxin; Dong, Shuangshi; Tian, Xiadi; Cui, Bin; Xiong, Houfeng; Li, Tingting; Ma, Dongmei
2015-07-07
Intimate coupling of photocatalysis and biodegradation (ICPB) technology is attractive for phenolic wastewater treatment, but has only been investigated using UV light (called UPCB). We examined the intimate coupling of visible-light-induced photocatalysis and biodegradation (VPCB) for the first time. Our catalyst was prepared doping both of Er(3+) and YAlO3 into TiO2 which were supported on macroporous carriers. The macroporous carriers was used to support for the biofilms as well. 99.8% removal efficiency of phenol was achieved in the VPCB, and this was 32.6% higher than that in the UPCB. Mineralization capability of UPCB was even worse, due to less adsorbable intermediates and cell lysis induced soluble microbial products release. The lower phenol degradation in the UPCB was due to the serious detachment of the biofilms, and then the microbes responsible for phenol degradation were insufficient due to disinfection by UV irradiation. In contrast, microbial communities in the carriers were well protected under visible light irradiation and extracellular polymeric substances secretion was enhanced. Thus, we found that the photocatalytic reaction and biodegradation were intimately coupled in the VPCB, resulting in 64.0% removal of dissolved organic carbon. Therefore, we found visible light has some advantages over UV light in the ICPB technology.
Survival of Poliovirus in Flowing Turbid Seawater Treated with Ultraviolet Light
Hill, W. F.; Hamblet, F. E.; Akin, E. W.
1967-01-01
The effectiveness of a model ultraviolet (UV) radiation unit for treating flowing turbid seawater contaminated with poliovirus was determined. At a turbidity of 70 ppm, the observed survival ratios ranged from 1.9 × 10-3 (99.81% reduction) to 1.5 × 10-4 (99.98% reduction) at flow rates ranging from 25 to 15 liters/min; no virus was recovered at flow rates of 10 and 5 liters/min. At a turbidity of 240 ppm, the observed survival ratios ranged from 3.2 × 10-2 (96.80% reduction) to 2.1 × 10-4 (99.98% reduction) at flow rates ranging from 25 to 5 liters/min. As expected, turbidity had an adverse influence on the effectiveness of UV radiation; however, by adjusting the flow rate of the seawater through the treatment unit, adequate disinfection was shown to be predictable. Images Fig. 1 PMID:4291955
2006-06-01
The authors thank Denise Aylor (613) and Erick Satchell (613) for performing the cavitation erosion measurements and JoAnn Burkholder (North Carolina...20376 CODE 613 (AYLOR) 1 CODE 613 (SATCHELL) 1 COMMANDER CODE 617 (LEE, JOHN ) 1 NAVAL SURFACE WARFARE CENTER CODE 617 (BRIZZOLARA) 10 DAHLGREN...WUN-FOGLE) 10 CODE 702 (STRASBORG) 1 DEFENSE TECHNICAL INFORMATION CODE 3442 (TIC) 1 CENTER 8725 JOHN KINGMAN ROAD SUITE 0944 FORT BELVOIR VA 22060
Micropollutants removal by full-scale UV-C/sulfate radical based Advanced Oxidation Processes.
Rodríguez-Chueca, J; Laski, E; García-Cañibano, C; Martín de Vidales, M J; Encinas, Á; Kuch, B; Marugán, J
2018-07-15
The high chemical stability and the low biodegradability of a vast number of micropollutants (MPs) impede their correct treatment in urban wastewater treatment plants. In most cases, the chemical oxidation is the only way to abate them. Advanced Oxidation Processes (AOPs) have been experimentally proved as efficient in the removal of different micropollutants at lab-scale. However, there is not enough information about their application at full-scale. This manuscript reports the application of three different AOPs based on the addition of homogeneous oxidants [hydrogen peroxide, peroxymonosulfate (PMS) and persulfate anions (PS)], in the UV-C tertiary treatment of Estiviel wastewater treatment plant (Toledo, Spain) previously designed and installed in the facility for disinfection. AOPs based on the photolytic decomposition of oxidants have been demonstrated as more efficient than UV-C radiation alone on the removal of 25 different MPs using low dosages (0.05-0.5 mM) and very low UV-C contact time (4-18 s). Photolysis of PMS and H 2 O 2 reached similar average MPs removal in all the range of oxidant dosages, obtaining the highest efficiency with 0.5 mM and 18 s of contact time (48 and 55% respectively). Nevertheless, PMS/UV-C reached slightly higher removal than H 2 O 2 /UV-C at low dosages. So, these treatments are selective to degrade the target compounds, obtaining different removal efficiencies for each compound regarding the oxidizing agent, dosages and UV-C contact time. In all the cases, H 2 O 2 /UV-C is more efficient than PMS/UV-C, comparing the ratio cost:efficiency (€/m 3 ·order). Even H 2 O 2 /UV-C treatments are more efficient than UV-C alone. Thus, the addition of 0.5 mM of H 2 O 2 compensates the increased of UV-C contact time and therefore the increase of electrical consumption, that it should be need to increase the removal of MPs by UV-C treatments alone. Copyright © 2018 Elsevier B.V. All rights reserved.
Ostoich, M; Serena, F; Falletti, L; Fantoni, A
2013-01-01
Directive 2000/60/EC requires the achievement of a 'good chemical status' for surface water within pre-established dates. Disinfection is needed to achieve compulsory final microbial limit values (in Italy for wastewater discharges the parameter Escherichia coli - EC - is imposed by law with a maximum limit value of 5,000 cfu/100 mL). Liquid waste and disinfection by-products must be considered when designing appropriate monitoring of dangerous substances; the specific classes of substances must be investigated according to the typology of received wastewaters and liquid wastes (where applicable) and specific analytical techniques, with Limit of Detection (LOD) lower than the limit values, must be applied; the difficulties faced by national and regional environmental control Agencies is that these techniques have to be applied during ordinary activity and not only for research purposes. The study aims to present the control of dangerous substances, as a screening view, in wastewater treatment plant (WWTP) discharges in the province of Venice (Northern Italy) for the period 2007-2010 based on available data from institutional controls. In addition, the wastewater disinfection process with ozone applied to a medium size WWTP (45,000 Population Equivalents) is presented as a case study, with a view to assessing the microbiological abatement efficacy and the presence of dangerous substances. Discharge quality of the WWTPs in the province of Venice presented mean values that were higher than the LOD, but only for certain metals. For the Paese plant, zinc and chloroform were the only micro-pollutants detected with a higher level than the LOD. From microbiological data in the period 2006-2011 the disinfection abatement efficiency for Paese was, in most cases above 99% for EC, faecal coliform (FC), faecal streptococci (FS) while efficiency was slightly lower for total coliform (TC); however, the proposed criterion aimed at respecting 99.99% abatement was not completely satisfied. Therefore, despite the high organic and industrial load of the considered plant and the need to find an alternative system for chlorine, as chlorine disinfection has been banned in the Veneto region since December 2012, ozone efficiency is not completely satisfactory and other systems such as peracetic or performic acids and UV systems must be considered.
[Ru/AC catalyzed ozonation of recalcitrant organic compounds].
Wang, Jian-Bing; Hou, Shao-Pei; Zhou, Yun-Rui; Zhu, Wan-Peng; He, Xu-Wen
2009-09-15
Ozonation and Ru/AC catalyzed ozonation of dimethyl phthalate (DMP), phenols and disinfection by-products precursors were studied. It shows that Ru/AC catalyst can obviously enhance the mineralization of organic compounds. In the degradation of DMP, TOC removal was 28.84% by ozonation alone while it was 66.13% by catalytic ozonation. In the oxidation of 23 kinds of phenols, TOC removals were 9.57%-56.08% by ozonation alone while they were 41.81%-82.32% by catalytic ozonation. Compared to ozonation alone, Ru/AC catalyzed ozonation was more effective for the reduction of disinfection by-products formation potentials in source water. The reduction of haloacetic acids formation potentials was more obvious than thichlomethane formation potentials. After the treatment by catalytic ozonation, the haloacetic acids formation potentials decreased from 144.02 microg/L to 58.50 microg/L, which was below the standard value of EPA. However ozonation alone could not make it reach the standard. The treatments of source water by BAC, O3 + BAC, O3/AC + BAC and Ru/AC + O3 + BAC were also studied. In the four processes, TOC removal was 3.80%, 20.14%, 27.45% and 48.30% respectively, COD removal was 4.37%, 27.22%, 39.91% and 50.00% respectively, UV254 removal was 8.16%, 62.24%, 67.03% and 84.95% respectively. Ru/AC + O3 + BAC process is more effective than the other processes for the removal of TOC, COD and UV254 and no ruthenium leaching observed in the solution. It is a promising process for the treatment of micro polluted source water.
Franklin, Samuel Patrick; Stoker, Aaron M; Cockrell, Mary K; Pfeiffer, Ferris M; Sonny Bal, B; Cook, James L
2012-01-01
Our objective was to determine whether low-temperature hydrogen peroxide (H2O2) gas plasma sterilization of porous three-dimensional poly(ϵ-caprolactone) (PCL) constructs significantly inhibits cellular metabolism of canine chondrocytes. Porous cylindrical constructs were fabricated using fused deposition modeling and divided into four sterilization groups. Two groups were sterilized with low-temperature H2O2 gas plasma (LTGP) and constructs from one of those groups were subsequently rinsed with Dulbecco's Modified Essential Media (LTGPDM). Constructs in the other two groups were disinfected with either 70% isopropyl alcohol or exposure to UV light. Canine chondrocytes were seeded in 6-well tissue-culture plates and allowed to adhere prior to addition of PCL. Cellular metabolism was assessed by adding resazurin to the tissue-culture wells and assessing conversion of this substrate by viable cells to the fluorescent die resorufin. This process was performed at three times prior to addition of PCL and at four times after addition of PCL to the tissue-culture wells. Metabolism was not significantly different among the different tissue-culture wells at any of the 3 times prior to addition of PCL. Metabolism was significantly different among the treatment groups at 3 of 4 times after addition of PCL to the tissue culture wells. Metabolism was significantly lower with constructs sterilized by LTGP than all other treatment groups at all 3 of these times. We conclude that LTGP sterilization of PCL constructs resulted in significant cytotoxicity to canine chondrocytes when compared to PCL constructs disinfected with either UV light exposure or 70% isopropyl alcohol.