Sample records for vacuum assisted delivery

  1. Risk factors for anal sphincter tears in vacuum-assisted delivery.

    PubMed

    Ryman, P; Ahlberg, M; Ekéus, C

    2015-10-01

    The aim of the present study was to describe the prevalence of anal sphincter tears (AST) in relation to obstetric management and technique during vacuum extraction deliveries (VE) (re: indications, the station of the fetal head at application of the cup, number of tractions, the length for the extraction, cup detachments, pain relief, episiotomy, fetal presentation, and experience of the operator) as well as maternal and infant anthropometrics. Descriptive study. Data on six hundred vacuum extraction deliveries were consecutively collected from six different delivery units in Sweden. Each unit contributed with data on 100 deliveries. The final study population included 596 women who delivered by vacuum extraction. There was no correlation between the management of the vacuum extraction and risk for anal sphincter tear. Women from Africa had nearly a fourfold risk for anal sphincter tear during vacuum-assisted delivery compared with Swedish-born women (OR 3.82 CI 1.47-9.89). Compared with infants with birth weight less than 4000 g, birth weight above 4000 g was associated with increased risk of AST (OR 1.87 CI 1.06-3.28). In this study, the obstetric management in VE-assisted deliveries did not impact the risk of AST. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. [Assessment of vacuum-assisted vaginal delivery in a frank breech presentation].

    PubMed

    Bleu, G; Deruelle, P; Demetz, J; Michel, S; Dufour, P; Depret, S; Subtil, D

    2015-02-01

    After verification of the eligibility criteria and with an obstetrician familiar with the specific maneuvers likely to be needed, vaginal delivery of breech presentations is possible. If problems arise during the active pushing phase of labor, vacuum extraction has been described in the literature for this uncommon condition with limited series. The aim of this study is to assess retrospectively vacuum extraction in frank breech presentation in our center. This retrospective study of trials of vaginal delivery of fetuses in breech presentation at term compares cases according to whether they did or did not use a vacuum extraction. During a two-year period, 83 patients, whom had trials of vaginal delivery in breech presentations, reached the active pushing/bearing down stage after complete cervical dilatation. Vacuum assistance was applied in six of these (7.2 %). The failure rate for vaginal delivery was significantly higher in the group with compared to without vacuum extraction (33.3 % versus 6.5 %, P<0.05). Moreover, the mean pH at birth was significantly lower in the group with vacuum extraction (7.12±0.11 versus 7.20±0.08, P<0.05), and these infants more frequently had deep cutaneous injuries (66.7 % versus 26.0 %, P<0.05). In fetuses in breech presentation, when vaginal delivery failed, it seems to be safer for the fetuses to perform caesarean section rather than attempt vacuum extraction. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  3. Occiput posterior fetal head position increases the risk of anal sphincter injury in vacuum-assisted deliveries.

    PubMed

    Wu, Jennifer M; Williams, Kathryn S; Hundley, Andrew F; Connolly, AnnaMarie; Visco, Anthony G

    2005-08-01

    The purpose of this study was to determine whether an occiput posterior (OP) fetal head position increases the risk for anal sphincter injury when compared with an occiput anterior (OA) position in vacuum-assisted deliveries. We conducted a retrospective cohort study of 393 vacuum-assisted singleton vaginal deliveries. Maternal demographics and obstetric and neonatal data were collected from an obstetric database and chart review. Within the OP group, 41.7% developed a third- or fourth-degree laceration compared with 22.0% in the OA group (OR 2.5, 95% CI 1.4-4.7). In a logistic regression model that controlled for BMI, race, nulliparity, length of second stage, episiotomy, birth weight, head circumference, and fetal head position, OP position was 4.0 times (95% CI 1.7-9.6) more likely to be associated with an anal sphincter injury than OA position. Among vacuum deliveries, an OP head position confers an incrementally increased risk for anal sphincter injury over an OA position.

  4. Prospective cohort study of a new vacuum delivery device to assist with complicated labour in low-resource settings.

    PubMed

    Khan, Mishal; Hashmani, Farah Naz; Ahmed, Sajjad; Ahmed, Owais; Asim, Shabnam S; Wajahat, Yasmin; Sobani, Shoaib; Syed, Shershah; Qazi, Fahad

    2015-02-01

    Currently available vacuum devices used to assist women undergoing complicated labour are unsuitable for use in low-resource settings. The objective of this study was to evaluate the safety and feasibility of a new low-cost vacuum device, named Koohi Goth Vacuum Delivery System (KGVDS), designed for use in low-resource settings. A hospital-based, multicentre, prospective cohort study with no control group was conducted in Karachi, Pakistan. After training, KGVDS devices were made available for use by labour room staff at their discretion when instrumental delivery was indicated. Women to whom KGVDS was applied were followed from the start of labour until discharge. Feasibility was assessed in terms of successful expulsion of the foetal head following application of KGVDS and ease of use ratings. Safety was assessed by observing maternal and newborn post-delivery outcomes prior to discharge. Koohi Goth Vacuum Delivery System was applied to 137 women requiring instrumental delivery, of whom 111 (81%; 95% CI = 74-88%) successfully expelled the foetal head assisted by KGVDS and 103 (75%) stated that they would agree to use KGVDS again. There were no serious maternal or neonatal injuries or infections related to KGVDS use. The mean score for 'ease of use' given by doctors and midwives using the device was 8 of 10. Koohi Goth Vacuum Delivery System was feasible and safe to use for assisting complicated deliveries in low-resource hospitals in this initial evaluation. Our results indicate that this new device may have the potential to improve birth outcomes in settings where most mortality occurs and that further evaluations should be conducted. © 2014 John Wiley & Sons Ltd.

  5. 49 CFR 570.56 - Vacuum brake assist unit and vacuum brake system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... The following requirements apply to vehicles with vacuum brake assist units and vacuum brake systems. (a) Vacuum brake assist unit integrity. The vacuum brake assist unit shall demonstrate integrity as... maintained on the pedal. (1) Inspection procedure. Stop the engine and apply service brake several times to...

  6. Cup detachment during vacuum-assisted vaginal delivery and birth outcome.

    PubMed

    Krispin, Eyal; Aviram, Amir; Salman, Lina; Chen, Rony; Wiznitzer, Arnon; Gabbay-Benziv, Rinat

    2017-11-01

    To determine the perinatal outcome associated with cup detachment during vacuum-assisted vaginal delivery (VAVD). A retrospective cohort study of all women attempting VAVD in a tertiary hospital (2012-2014). Singleton-term pregnancies were included. Antepartum fetal death and major fetal structural or chromosomal abnormalities were excluded. Primary outcome was neonatal birth trauma (subgaleal hematoma, subarachnoid hematoma, subdural hematoma, skull fracture, and/or erb's palsy). Secondary outcomes were maternal complications or other neonatal morbidities. Outcomes were compared between women after ≥1 cup detachment (study group) and the rest (control group). Logistic regression analysis was utilized to adjust results to potential confounders. Overall, 1779 women attempted VAVD during study period. Of them, in 146 (8.2%), the cup detached prior to delivery; 130/146 (89%) had a single detachment. After detachment, 4 (2.7%) delivered by cesarean section, 77 (52.7%) delivered after cup reapplication, and 65 (44.6%) delivered spontaneously. Women in the study group were more likely to undergo VAVD due to prolonged second stage, and were characterized by lower rates of metal cup use. Neonates in the detachment group had higher rates of subarachnoid hematoma and composite neonatal birth trauma (2.7 vs. 0.1% and 4.8 vs. 1.8%, respectively, p < 0.05). This remained significant after adjustment to potential confounders (subarachnoid hematoma aOR = 45.44, 95% CI 6.42-321.62 and neonatal birth trauma aOR = 2.62, 95% CI 1.1-6.22, p < 0.05 for all). Other neonatal and maternal morbidities were similar between groups. Cup detachment is associated with a higher rate of adverse neonatal outcome. Cup reapplication should be considered carefully.

  7. Vacuum-assisted venous return reduces blood usage.

    PubMed

    Banbury, Michael K; White, Jennifer A; Blackstone, Eugene H; Cosgrove, Delos M

    2003-09-01

    To determine whether vacuum-assisted venous return has clinical advantages over conventional gravity drainage apart from allowing the use of smaller cannulas and shorter tubing. A total of 150 valve operations were performed at our institution between February and July 1999 using vacuum-assisted venous return with small venous cannulas connected to short tubing. These were compared with (1) 83 valve operations performed between April 1997 and January 1998 using the initial version of vacuum-assisted venous return, and (2) 124 valve operations performed between January and April of 1997 using conventional gravity drainage. Priming volume, hematocrit value, red blood cell usage, and total blood product usage were compared multivariably. These comparisons were covariate and propensity adjusted for dissimilarities between the groups and confirmed by propensity-matched pairs analysis. Priming volume was 1.4 +/- 0.4 L for small-cannula vacuum-assisted venous return, 1.7 +/- 0.4 L for initial vacuum-assisted venous return, and 2.0 +/- 0.4 L for gravity drainage (P <.0001). Smaller priming resulted in higher hematocrit values both at the beginning of cardiopulmonary bypass (27% +/- 5% compared with 26% +/- 4% and 25% +/- 4%, respectively, P <.0001) and at the end (30% +/- 4% compared with 28% +/- 4% and 27% +/- 4%, respectively, P <.0001). Red cell transfusions were used in 17% of the patients having small-cannula vacuum-assisted venous return, 27% of the initial patients having vacuum-assisted venous return, and 37% of the patients having gravity drainage (P =.001); total blood product usage was 19%, 27%, and 39%, respectively (P =.002). Although ministernotomy also was associated with reduced blood product usage (P <.004), propensity matching on type of sternotomy confirmed the association of vacuum-assisted venous return with lowered blood product usage. Vacuum-assisted venous return results in (1) higher hematocrit values during cardiopulmonary bypass and (2) decreased

  8. Intrapartum translabial ultrasound with pushing used to predict the difficulty in vacuum-assisted delivery of fetuses in non-occiput posterior position.

    PubMed

    Antonio Sainz, José; Borrero, Carlota; Aquise, Adriana; García-Mejido, José Antonio; Gutierrez, Laura; Fernández-Palacín, Ana

    2016-10-01

    Our aim is to evaluate the capacity of intrapartum translabial ultrasound (ITU) with pushing in the prediction of difficulty of fetal extraction in vacuum assisted deliveries. Prospective, observational study performed (2/2015-8/2015) on 75 nulliparous women, ≥37 weeks with singleton pregnancies at full dilatation who had ITU-with-pushing performed, previous to vacuum-placement for fetal extraction. Working on the translabial sagittal-plane, we assessed: Angle-Progression (AoP), Progression-Distance (PD) and Head-Direction (HD); in the axial plane we evaluated: Midline-Angle (MLA) and Head-Perineum-Distance (HPD). Vacuum extractions were classified as easy-difficulty (ED) (≤3 vacuum-pulls), difficult-unsuccessful (DD) (>3 vacuum-pulls). We did not assess occipito-posterior-presentations. Seventy nulliparous were studied (44-ED,26-DD). We observed no differences in obstetric, neonatal or intrapartum characteristics between the two study groups, with the following exceptions: newborn weight (3272 ± 438 g versus 3540 ± 372 g; p = 0.011) and number of vacuum-pulls (1.4-ED-vs-4.4-DD; p < 0.0005). AoP-pushing was 143.9° ± 14.6° in ED and 115.1°± 12.9° in DD (p < 0.0005); Head-Up was 79.5% versus 38.4% (p < 0.0005); PD-Pushing was 42.7 ± 11.3 mm versus 30.4 ± 9.8 mm (p < 0.0005); MLA-Pushing was 27.6°± 26.6° versus 57.5°±26.5°(p=0.025); HPD-Pushing was 40.8 ± 10.0 mm versus 47.4 ± 10.9 mm (p = 0.039). We identified that the presence of an AoP-Pushing > 128° predicts an Easy-Vacuum-Delivery (≤3 Vacuum-Pulls) in  >85% of cases (Sen 80%-FPR 9.3%).

  9. 21 CFR 864.9125 - Vacuum-assisted blood collection system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vacuum-assisted blood collection system. 864.9125... Blood and Blood Products § 864.9125 Vacuum-assisted blood collection system. (a) Identification. A vacuum-assisted blood collection system is a device intended for medical purposes that uses a vacuum to...

  10. 21 CFR 864.9125 - Vacuum-assisted blood collection system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Vacuum-assisted blood collection system. 864.9125... Blood and Blood Products § 864.9125 Vacuum-assisted blood collection system. (a) Identification. A vacuum-assisted blood collection system is a device intended for medical purposes that uses a vacuum to...

  11. 21 CFR 864.9125 - Vacuum-assisted blood collection system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Vacuum-assisted blood collection system. 864.9125... Blood and Blood Products § 864.9125 Vacuum-assisted blood collection system. (a) Identification. A vacuum-assisted blood collection system is a device intended for medical purposes that uses a vacuum to...

  12. 21 CFR 864.9125 - Vacuum-assisted blood collection system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Vacuum-assisted blood collection system. 864.9125... Blood and Blood Products § 864.9125 Vacuum-assisted blood collection system. (a) Identification. A vacuum-assisted blood collection system is a device intended for medical purposes that uses a vacuum to...

  13. 21 CFR 864.9125 - Vacuum-assisted blood collection system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Vacuum-assisted blood collection system. 864.9125... Blood and Blood Products § 864.9125 Vacuum-assisted blood collection system. (a) Identification. A vacuum-assisted blood collection system is a device intended for medical purposes that uses a vacuum to...

  14. Fast MRI-guided vacuum-assisted breast biopsy: initial experience.

    PubMed

    Liberman, Laura; Morris, Elizabeth A; Dershaw, D David; Thornton, Cynthia M; Van Zee, Kimberly J; Tan, Lee K

    2003-11-01

    The purpose of this study was to evaluate a new method for performing MRI-guided vacuum-assisted breast biopsy in a study of lesions that had subsequent surgical excision. SUBJECTS AND METHODS. Twenty women scheduled for MRI-guided needle localization and surgical biopsy were prospectively entered in the study. MRI-guided biopsy was performed with a vacuum-assisted probe, followed by placement of a localizing clip, and then needle localization for surgical excision. Vacuum-assisted biopsy and surgical histology were correlated. Vacuum-assisted biopsy was successfully performed in 19 (95%) of the 20 women. The median size of 27 MRI-detected lesions that had biopsy was 1.0 cm (range, 0.4-6.4 cm). Cancer was present in eight (30%) of 27 lesions and in six (32%) of 19 women; among these eight cancers, five were infiltrating and three were ductal carcinoma in situ (DCIS). Among these 27 lesions, histology was benign at vacuum-assisted biopsy and at surgery in 19 (70%), cancer at vacuum-assisted biopsy in six (22%), atypical ductal hyperplasia at vacuum-assisted biopsy and DCIS at surgery in one (4%), and benign at vacuum-assisted biopsy with surgery showing microscopic DCIS that was occult at MRI in one (4%). The median time to perform vacuum-assisted biopsy of a single lesion was 35 min (mean, 35 min; range, 24-48 min). Placement of a localizing clip, attempted in 26 lesions, was successful in 25 (96%) of 26, and the clip was retrieved on specimen radiography in 22 (96%) of 23. One complication occurred: a hematoma that resolved with compression. MRI-guided vacuum-assisted biopsy is a fast, safe, and accurate alternative to surgical biopsy for breast lesions detected on MRI.

  15. Assisted Vaginal Delivery

    MedlinePlus

    ... Patient Education FAQs Assisted Vaginal Delivery Patient Education Pamphlets - Spanish Assisted Vaginal Delivery FAQ192, February 2016 PDF ... on Patient Safety For Patients Patient FAQs Spanish Pamphlets Teen Health About ACOG About Us Leadership & Governance ...

  16. Vacuum assisted birth and risk for cerebral complications in term newborn infants: a population-based cohort study.

    PubMed

    Ekéus, Cecilia; Högberg, Ulf; Norman, Mikael

    2014-01-20

    Few studies have focused on cerebral complications among newborn infants delivered by vacuum extraction (VE). The aim of this study was to determine the risk for intracranial haemorrhage and/or cerebral dysfunction in newborn infants delivered by VE and to compare this risk with that after cesarean section in labour (CS) and spontaneous vaginal delivery, respectively. Data was obtained from Swedish national registers. In a population-based cohort from 1999 to 2010 including all singleton newborn infants delivered at term after onset of labour by VE (n = 87,150), CS (75,216) or spontaneous vaginal delivery (n = 851,347), we compared the odds for neonatal intracranial haemorrhage, traumatic or non-traumatic, convulsions or encephalopathy. Logistic regressions were used to calculate adjusted (for major risk factors and indication) odds ratios (AOR), using spontaneous vaginal delivery as reference group. The rates of traumatic and non-traumatic intracranial hemorrhages were 0.8/10,000 and 3.8/1,000. VE deliveries provided 58% and 31.5% of the traumatic and non-traumatic cases, giving a ten-fold risk [AOR 10.05 (4.67-21.65)] and double risk [AOR 2.23 (1.57-3.16)], respectively. High birth weight and short mother were associated with the highest risks. Infants delivered by CS had no increased risk for intracranial hemorrhages. The risks for convulsions or encephalopathy were similar among infants delivered by VE and CS, exceeding the OR after non-assisted spontaneous vaginal delivery by two-to-three times. Vacuum assisted delivery is associated with increased risk for neonatal intracranial hemorrhages. Although causality could not be established in this observational study, it is important to be aware of the increased risk of intracranial hemorrhages in VE deliveries, particularly in short women and large infants. The results warrant further studies in decision making and conduct of assisted vaginal delivery.

  17. [The evolution of vacuum extraction in obstetrics].

    PubMed

    Nikolov, A

    2010-01-01

    Vacuum extraction is one of the methods for assisted vaginal delivery. In this article the evolution of vacuum extraction in obstetrics is been discussed. Historical facts and data from the invention up to state-of-the-art vacuum systems in modern obstetrics are presented.

  18. Vacuum-assisted drainage in cardiopulmonary bypass: advantages and disadvantages

    PubMed Central

    de Carvalho Filho, Élio Barreto; Marson, Fernando Augusto de Lima; da Costa, Loredana Nilkenes Gomes; Antunes, Nilson

    2014-01-01

    Systematic review of vacuum assisted drainage in cardiopulmonary bypass, demonstrating its advantages and disadvantages, by case reports and evidence about its effects on microcirculation. We conducted a systematic search on the period 1997-2012, in the databases PubMed, Medline, Lilacs and SciELO. Of the 70 selected articles, 26 were included in the review. Although the vacuum assisted drainage has significant potential for complications and requires appropriate technology and professionalism, prevailed in literature reviewed the concept that vacuum assisted drainage contributed in reducing the rate of transfusions, hemodilutions, better operative field, no significant increase in hemolysis, reduced complications surgical, use of lower prime and of smaller diameter cannulas. PMID:25140478

  19. Vacuum-assisted drainage in cardiopulmonary bypass: advantages and disadvantages.

    PubMed

    Carvalho Filho, Elio Barreto de; Marson, Fernando Augusto de Lima; Costa, Loredana Nilkenes Gomes da; Antunes, Nilson

    2014-01-01

    Systematic review of vacuum assisted drainage in cardiopulmonary bypass, demonstrating its advantages and disadvantages, by case reports and evidence about its effects on microcirculation. We conducted a systematic search on the period 1997-2012, in the databases PubMed, Medline, Lilacs and SciELO. Of the 70 selected articles, 26 were included in the review. Although the vacuum assisted drainage has significant potential for complications and requires appropriate technology and professionalism, prevailed in literature reviewed the concept that vacuum assisted drainage contributed in reducing the rate of transfusions, hemodilutions, better operative field, no significant increase in hemolysis, reduced complications surgical, use of lower prime and of smaller diameter cannulas.

  20. Vacuum delivery at The Maternity Hospital Kuala Lumpur: a comparison of metal and silicone cups.

    PubMed

    Lee, H Y; Subramaniam, N; Nordin, M M

    1996-02-01

    To compare the advantages and disadvantages of the New Bird metal cups and silicone cups in terms of maternal and foetal outcome. To study the adverse effects and factors associated with failed vacuum deliveries. A prospective randomised study of all vacuum deliveries from 1 December 1991 to 31 April 1992. The Hanshin electrical vacuum pump was used. A large obstetric unit-The Maternity Hospital Kuala Lumpur (MHKL). Seventy-two consecutive patients where vacuum deliveries were indicated. Forty had metal and 32 had silicone cups. Another 7 vacuum deliveries using the manual vacuum pump were excluded. Success rate of vaginal delivery, birth canal injuries, post-partum haemorrhage, duration of hospital stay, Apgar score, foetal injuries (scalp-ecchymosis, haematomas) neonatal jaundice, the rate of special care nursery (SCN) admission and neonatal mortality rate. Failure to deliver with silicone cups alone was 21.9% compared to 10% for metal cups alone. Material morbidities and serious foetal scalp injuries were almost the same in both cups. However, minor foetal scalp injuries were significantly lower with silicone cups. Maternal height and baby's weight had no independent predictive values for successful vacuum delivery. When the foetal head was palpable per abdomen, the failure rate was 54.5% compared to 8.2% when it was not. Failed vacuum deliveries were associated with increased maternal and foetal morbidities. Silicone cups and metal cups can be equally dangerous to the baby. Although our sample size was small, we recommend that vacuum delivery be avoided if the foetal head is palpable per abdomen.

  1. Window-assisted nanosphere lithography for vacuum micro-nano-electronics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Nannan; Institute of Electronic Engineering, Chinese Academy of Engineering Physics, Mianyang, 621900; Pang, Shucai

    2015-04-15

    Development of vacuum micro-nano-electronics is quite important for combining the advantages of vacuum tubes and solid-state devices but limited by the prevailing fabricating techniques which are expensive, time consuming and low-throughput. In this work, window-assisted nanosphere lithography (NSL) technique was proposed and enabled the low-cost and high-efficiency fabrication of nanostructures for vacuum micro-nano-electronic devices, thus allowing potential applications in many areas. As a demonstration, we fabricated high-density field emitter arrays which can be used as cold cathodes in vacuum micro-nano-electronic devices by using the window-assisted NSL technique. The details of the fabricating process have been investigated. This work provided amore » new and feasible idea for fabricating nanostructure arrays for vacuum micro-nano-electronic devices, which would spawn the development of vacuum micro-nano-electronics.« less

  2. Management of hidradenitis suppurativa wounds with an internal vacuum-assisted closure device.

    PubMed

    Chen, Y Erin; Gerstle, Theodore; Verma, Kapil; Treiser, Matthew D; Kimball, Alexandra B; Orgill, Dennis P

    2014-03-01

    Hidradenitis suppurativa is a chronic, debilitating disease that is difficult to treat. Once medical management fails, wide local excision offers the best chance for cure. However, the resultant wound often proves too large or contaminated for immediate closure. The authors performed a retrospective chart review of hidradenitis cases managed surgically between 2005 and 2010. Data collected included patient characteristics, management method, and outcomes. Approximately half of the patients received internal vacuum-assisted closure therapy using the vacuum-assisted closure system and delayed closure and half of the patients received immediate primary closure at the time of their excision. Delayed closure consisted of closing the majority of the wound in a linear fashion following internal vacuum-assisted closure while accepting healing by means of secondary intention for small wound areas. Patients managed with internal vacuum-assisted closure had wounds on average four times larger in area than patients managed without internal vacuum-assisted closure. In both groups, all wounds were eventually closed primarily. Healing times averaged 2.2 months with internal vacuum-assisted closure and 2.7 months without. At an average follow-up time of 2.3 months, all patients with internal vacuum-assisted closure had no recurrence of their local disease. Severe hidradenitis presents a treatment challenge, as surgical excisions are often complicated by difficult closures and unsatisfactory recurrence rates. This study demonstrates that wide local excision with reasonable outcomes can be achieved using accelerated delayed primary closure. This method uses internal vacuum-assisted closure as a bridge between excision and delayed primary closure, facilitating closure without recurrence in large, heavily contaminated wounds. Therapeutic, III.

  3. Does vacuum delivery carry a higher risk of shoulder dystocia? Review and meta-analysis of the literature.

    PubMed

    Dall'Asta, Andrea; Ghi, Tullio; Pedrazzi, Giuseppe; Frusca, Tiziana

    2016-09-01

    Vacuum extractor has been increasingly used over the last decades and is acknowledged as a risk factor for shoulder dystocia (SD). In this meta-analysis we assess the actual risk of SD following a vacuum delivery compared to spontaneous vaginal delivery (SVD) and forceps. Systematic literature search (English literature only) on MEDLINE, EMBASE, ScienceDirect, the Cochrane library and ClinicalTrials.gov conducted up to May 2015. Key search terms included: Operative/Vacuum/Forceps delivery [Mesh] and shoulder dystocia and subheadings. 2 stage-process study selection. We included only studies where data concerning the occurrence of SD following operative vaginal delivery were reported as adjusted odds ratio (AOR) and no significant difference in confounding factors for SD was recorded. Included trials clustered according to the delivery mode (1) vacuum vs. SVD, (2) forceps vs. vacuum. Methodological quality of each study evaluated with the Newcastle-Ottawa System (NOS). 87 potentially relevant papers. After applying inclusion and exclusion criteria only 7 were selected for the meta-analysis. Vacuum delivery appeared associated with a higher risk of SD than SVD in both fixed and random model (OR 2.87 and 2.98 respectively). No difference in the rate of SD was found between vacuum and forceps (p>0.05). Vacuum extractor carries an increased risk of SD compared with spontaneous vaginal delivery whereas the occurrence of SD does not seem to vary following vacuum or forceps. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  4. Obstetric management in vacuum-extraction deliveries.

    PubMed

    Ahlberg, Mia; Saltvedt, Sissel; Ekéus, Cecilia

    2016-06-01

    The aim of this observational study was to describe the obstetric management in vacuum extraction (VE) deliveries and to compare these findings to instructions in clinical guidelines on VE. In 2013, detailed data on management of 600 VE cases were consecutively collected from six different delivery units in Sweden. Each unit also contributed their own clinical VE guideline. In total, 93% of the VEs ended with a vaginal delivery while 7% failed and were converted to an emergency cesarean section. In 2.3% extraction time exceeded 20 minutes, and in 6% more than six pulls were used to deliver the fetus. Cup detachment occurred in 14.6%, and fundal pressure was used in 11% of the deliveries. In 2.3%, fetal station was assessed as above the level of the maternal ischial spines. The clinical guidelines on VE varied in scope and content between units, and were often incomplete according to best practice. The vast majority of the VEs were conducted in accordance with safety recommendations. However, in a few extractions, safety rules were disregarded and more than six pulls or an extraction time of more than 20 minutes were used to complete the delivery. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Emergent Embolization of Arterial Bleeding after Vacuum-Assisted Breast Biopsy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fischman, Aaron M., E-mail: aaron.fischman@mountsinai.org; Epelboym, Yan, E-mail: yan.epelboym@mssm.edu; Siegelbaum, Robert H., E-mail: rhsiegelbaum@gmail.com

    2012-02-15

    Vacuum-assisted core breast biopsy has become important in evaluating patients with suspicious breast lesions. It has proven to be a relatively safe procedure that in rare cases can result in vascular complications. These are the first reported cases of transcatheter embolization of uncontrolled breast hemorrhage after vacuum-assisted breast biopsy. With increased use of biopsy and larger-gauge devices, breast imaging groups may consider embolotherapy as a safe alternative for treatment of hemorrhage in a select group of patients.

  6. Comparison of outcomes between operative vaginal deliveries and spontaneous vaginal deliveries in southeast Nigeria.

    PubMed

    Lawani, Lucky O; Anozie, Okechukwu B; Ezeonu, Paul O; Iyoke, Chukwuemeka A

    2014-06-01

    To evaluate the incidence of, indications for, and outcome of operative vaginal deliveries compared with spontaneous vaginal deliveries in southeast Nigeria. A retrospective cohort study was conducted involving cases of operative vaginal delivery performed at Ebonyi State University Teaching Hospital over a 10-year period. Data on the procedures were abstracted from the operation notes of the medical records of parturients. An incidence of 4.7% (n = 461) was recorded. The most common indications for vacuum and forceps delivery were prolonged second stage of labor (44.9%) and poor maternal effort (27.8%). The only indication for destructive operation was intrauterine fetal death (3.7%). The risk ratio (RR) for hemorrhage/vulvar hematoma was 1.14 (95% confidence interval [CI], 0.53-2.48) for vacuum-assisted delivery and 5.49 (95% CI, 0.82-36.64) for forceps delivery. The RR for genital laceration was 1.21 (95% CI, 0.44-3.30) for vacuum-assisted delivery and 9.41 (95% CI, 1.33-66.65) for forceps delivery. The risk of fetal scalp bruises and caput succedaneum was higher for operative vaginal delivery than for spontaneous vaginal delivery, with no significant difference in maternal morbidity. The perinatal mortality rate was 0.9 per 1000 live births. Operative vaginal delivery by experienced healthcare providers is associated with good obstetric outcomes with minimal risk. Copyright © 2014 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  7. Vacuum-assisted closure therapy in the management of lung abscess.

    PubMed

    Sziklavari, Zsolt; Ried, Michael; Hofmann, Hans-Stefan

    2014-09-06

    Despite significant advances in the treatment of thoracic infections, complex lung abscess remains a problem in modern thoracic surgery. We describe the novel application of vacuum-assisted closure for the treatment of a lung abscess. The technical details and preliminary results are reported. After the initial failed conservative treatment of an abscess, minimally invasive surgical intervention was performed with vacuum-assisted closure. The vacuum sponges were inserted in the abscess cavity at the most proximal point to the pleural surface. The intercostal space of the chest wall above the entering place was secured by a soft tissue retractor. The level of suction was initially set to 100 mm Hg, with a maximum suction of 125 mm Hg. The sponge was changed once on the 3rd postoperative day. The abscess cavity was rapidly cleaned and decreased in size. The mini-thoracotomy could be closed on the 9th postoperative day. Closure of the cavity was simple, without any short- or long-term treatment failure. This technique reduced the trauma associated with the procedure. The patient was discharged on the 11th postoperative day. Vacuum-assisted closure systems should be considered for widespread use as an alternative option for the treatment of complicated pulmonary abscess in elderly, debilitated, immunocompromised patients after failed conservative treatment.

  8. The cost effectiveness of vacuum-assisted versus core-needle versus surgical biopsy of breast lesions.

    PubMed

    Fernández-García, P; Marco-Doménech, S F; Lizán-Tudela, L; Ibáñez-Gual, M V; Navarro-Ballester, A; Casanovas-Feliu, E

    To determine the cost effectiveness of breast biopsy by 9G vacuum-assisted guided by vertical stereotaxy or ultrasonography in comparison with breast biopsy by 14G core-needle biopsy and surgical biopsy. We analyzed a total of 997 biopsies (181 vacuum-assisted, 626 core, and 190 surgical biopsies). We calculated the total costs (indirect and direct) of the three types of biopsy. We did not calculate intangible costs. We measured the percentage of correct diagnoses obtained with each technique. To identify the most cost-effective option, we calculated the mean ratios for the three types of biopsies. Total costs were €225.09 for core biopsy, €638.90 for vacuum-assisted biopsy, and €1780.01 for surgical biopsy. The overall percentage of correct diagnoses was 91.81% for core biopsy, 94.03% for vacuum-assisted biopsy, and 100% for surgical biopsy; however, these differences did not reach statistical significance (p=0.3485). For microcalcifications, the percentage of correct diagnoses was 50% for core biopsy and 96.77% for vacuum-assisted biopsy (p<0.0001). For nodules, there were no significant differences among techniques. The mean cost-effectiveness ratio considering all lesions was 2.45 for core biopsy, 6.79 for vacuum-assisted biopsy, and 17.80 for surgical biopsy. Core biopsy was the dominant option for the diagnosis of suspicious breast lesions in general. However, in cases with microcalcifications, the low percentage of correct diagnoses achieved by core biopsy (50%) advises against its use in this context, where vacuum-assisted biopsy would be the technique of choice because it is more cost-effective than surgical biopsy, the other technique indicated for biopsying microcalcifications. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. Pregnancy week at delivery and the risk of shoulder dystocia: a population study of 2,014,956 deliveries.

    PubMed

    Øverland, E A; Vatten, L J; Eskild, A

    2014-01-01

    To study whether pregnancy week at delivery is an independent risk factor for shoulder dystocia. Population study. Medical Birth Registry of Norway. All vaginal deliveries of singleton offspring in cephalic presentation in Norway during 1967 through 2009 (n = 2,014,956). The incidence of shoulder dystocia was calculated according to pregnancy week at delivery. The associations of pregnancy week at delivery with shoulder dystocia were estimated as crude and adjusted odds ratios using logistic regression analyses. We repeated the analyses in pregnancies with and without maternal diabetes. Shoulder dystocia at delivery. The overall incidence of shoulder dystocia was 0.73% (n = 14,820), and the incidence increased by increasing pregnancy week at delivery. Birthweight was strongly associated with shoulder dystocia. After adjustment for birthweight, induction of labour, use of epidural analgesia at delivery, prolonged labour, forceps-assisted and vacuum-assisted delivery, parity, period of delivery and maternal age in multivariable analyses, the adjusted odds ratios for shoulder dystocia were 1.77 (1.42-2.20) for deliveries at 32-35 weeks of gestation, and 0.84 (0.79-0.88) at 42-43 weeks of gestation, using weeks 40-41 as the reference. In pregnancies affected by diabetes (n = 11,188), the incidence of shoulder dystocia was 3.95%, and after adjustment for birthweight the adjusted odds ratio for shoulder dystocia was 2.92 (95% CI 1.54-5.52) for deliveries at weeks 32-35 of gestation, and 0.91 (95% CI 0.50-1.66) at 42-43 weeks of gestation. The risk of shoulder dystocia was associated with increased birthweight, diabetes, induction of labour, use of epidural analgesia at delivery, prolonged labour, forceps-assisted and vacuum-assisted delivery, parity and period of delivery but not with post-term delivery. © 2013 Royal College of Obstetricians and Gynaecologists.

  10. 21. Engine identified as a 'single cylinder vacuum assist engine ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    21. Engine identified as a 'single cylinder vacuum assist engine for Tod tandem compound engine' showing compressor. - Carnegie Steel-Ohio Works, Steam Engines, 912 Salt Springs Road, Youngstown, Mahoning County, OH

  11. 20. Engine identified as a 'single cylinder vacuum assist engine ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    20. Engine identified as a 'single cylinder vacuum assist engine for the Tod tandem compound engine' showing crank end. - Carnegie Steel-Ohio Works, Steam Engines, 912 Salt Springs Road, Youngstown, Mahoning County, OH

  12. 19. Engine identified as a single cylinder vacuum assist engine ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    19. Engine identified as a single cylinder vacuum assist engine for the Filer and Stowell 15-inch continuous mill. - Carnegie Steel-Ohio Works, Steam Engines, 912 Salt Springs Road, Youngstown, Mahoning County, OH

  13. [Vacuum-assisted therapy for various wound types including diabetic foot ulcer].

    PubMed

    Farah, Raymond; Gantus, Maher; Kogan, Leonid

    2011-03-01

    Vacuum is a noninvasive system that creates a localized controlled negative pressure environment. In this study, vacuum was provided by the V.A.C. Therapy system, which promotes wound healing by delayed primary or secondary intention through creating a moist wound environment, preparing the wound bed for closure, reducing edema, and promoting formation and perfusion of granulation tissue. Vacuum-assisted closure therapy is indicated for use in all care settings and for a variety of wound types including diabetic foot ulcers. The purpose of this study was to evaluate safety and clinical efficacy of negative pressure wound therapy (NPWT) compared with advanced moist wound therapy and standard treatment to treat foot ulcers in diabetic patients. This trial enrolled 43 patients; most of them were diabetic patients at any age with various skin ulcers and diabetic foot. These patients were divided into two groups, 17 patients were treated with vacuum and the 26 patients in the control group were treated with standard therapy including debridement. A greater proportion of foot and skin ulcers achieved complete ulcer closure with vacuum-assisted therapy p<0.001 compared with the standard therapy. Vacuum therapy significantly decreased the duration and frequency of admission p=0.032 and decreased the rate of amputation p<0.001. Results of our trial support other studies and demonstrate that vacuum is as safe as and more efficacious than standard therapy in the treatment of diabetic foot ulcers. A significantly greater number of patients achieved complete ulcer closure and granulation tissue formation with this therapy. The study group showed a significant reduction in the median time needed to heal ulcers, reduction of the number of admissions and amputation frequency.

  14. Evaluation of a Prototype Hybrid Vacuum Pump to Provide Vacuum-Assisted Suspension for Above-Knee Prostheses

    PubMed Central

    Major, Matthew J.; Caldwell, Ryan; Fatone, Stefania

    2015-01-01

    Vacuum-assisted suspension (VAS) of prosthetic sockets utilizes a pump to evacuate air from between the prosthetic liner and socket, and are available as mechanical or electric systems. This technical note describes a hybrid pump that benefits from the advantages of mechanical and electric systems, and evaluates a prototype as proof-of-concept. Cyclical bench testing of the hybrid pump mechanical system was performed using a materials testing system to assess the relationship between compression cycles and vacuum pressure. Phase 1 in vivo testing of the hybrid pump was performed by an able-bodied individual using prosthesis simulator boots walking on a treadmill, and phase 2 involved an above-knee prosthesis user walking with the hybrid pump and a commercial electric pump for comparison. Bench testing of 300 compression cycles produced a maximum vacuum of 24 in-Hg. In vivo testing demonstrated that the hybrid pump continued to pull vacuum during walking, and as opposed to the commercial electric pump, did not require reactivation of the electric system during phase 2 testing. The novelty of the hybrid pump is that while the electric system provides rapid, initial vacuum suspension, the mechanical system provides continuous air evacuation while walking to maintain suspension without reactivation of the electric system, thereby allowing battery power to be reserved for monitoring vacuum levels. PMID:27462383

  15. Effects of epidural lidocaine analgesia on labor and delivery: A randomized, prospective, controlled trial

    PubMed Central

    Nafisi, Shahram

    2006-01-01

    Background Whether epidural analgesia for labor prolongs the active-first and second labor stages and increases the risk of vacuum-assisted delivery is a controversial topic. Our study was conducted to answer the question: does lumbar epidural analgesia with lidocaine affect the progress of labor in our obstetric population? Method 395 healthy, nulliparous women, at term, presented in spontaneous labor with a singleton vertex presentation. These patients were randomized to receive analgesia either, epidural with bolus doses of 1% lidocaine or intravenous, with meperidine 25 to 50 mg when their cervix was dilated to 4 centimeters. The duration of the active-first and second stages of labor and the neonatal apgar scores were recorded, in each patient. The total number of vacuum-assisted and cesarean deliveries were also measured. Results 197 women were randomized to the epidural group. 198 women were randomized to the single-dose intravenous meperidine group. There was no statistical difference in rates of vacuum-assisted delivery rate. Cesarean deliveries, as a consequence of fetal bradycardia or dystocia, did not differ significantly between the groups. Differences in the duration of the active-first and the second stages of labor were not statistically significant. The number of newborns with 1-min and 5-min Apgar scores less than 7, did not differ significantly between both analgesia groups. Conclusion Epidural analgesia with 1% lidocaine does not prolong the active-first and second stages of labor and does not increase vacuum-assisted or cesarean delivery rate. PMID:17176461

  16. Obstetric attending physician characteristics and their impact on vacuum and forceps delivery rates: University of California at San Francisco experience from 1977 to 1999.

    PubMed

    Chang, Anne Lynn S; Noah, Melinda Scully; Laros, Russell K

    2002-06-01

    The objective of our study was to determine the impact of obstetric attending physician characteristics (eg, region of previous residency training, sex, year of graduation from residency) on the rates of vacuum and forceps delivery at our institution. The analysis was based on 19,897 vaginal deliveries that were performed by 171 attending physicians and 160 resident physicians between 1977 and 1999 at the University of California at San Francisco Medical Center. Z -tests and multivariate logistic regression were performed on a perinatal database that contained standard obstetric variables. Male attending physicians had a higher percentage of forceps deliveries compared with female attending physicians (11.1% vs 6.6%; P <.001); female attending physicians had a higher percentage of vacuum deliveries compared with male attending physicians (9.8% vs 5.1%; P <.001). However, multivariate regression analysis revealed that only the year in which the procedure was performed affected both the forceps and vacuum delivery rates (P <.041). The region of previous residency training of the attending physician affected the vacuum delivery rate (P <.0001) but not the forceps delivery rate (P >.06) in multivariate logistic regression analysis. Factors such as the sex of the obstetric attending physician, the sex of the resident, and the year of graduation from residency for the obstetric attending physician did not have a significant impact on the forceps or vacuum delivery rates (all P >.05). Our study is the first to report that the apparent gender differences in forceps and vacuum delivery rates among obstetric attending physicians was due to the year in which the procedure was performed and not due to sex per se. We also found that the region of previous residency training for the obstetric attending physician significantly influenced the vacuum delivery rate.

  17. Vacuum-assisted delivery

    MedlinePlus

    ... MF, eds. Creasy and Resnik's Maternal-Fetal Medicine: Principles and Practice . 7th ed. Philadelphia, PA: Elsevier Saunders; ... member of Hi-Ethics and subscribes to the principles of the Health on the Net Foundation (www. ...

  18. A technological advance for 21st century obstetricians: the electronically-controlled vacuum extractor.

    PubMed

    Perone, Nicola

    2018-04-25

    To describe an innovative electronically-controlled vacuum extractor (VE) in detail and to illustrate its performance characteristics, as observed in a laboratory study. Thirty simulated, vacuum-assisted deliveries. (1) The ability to measure in real-time of the pull applied and to sound an alert, when the traction approaches the negative pressure under the cup, to prevent its detachment. (2) The recording and printing of a graphic representation of the pull applied (vacuum delivery graph). (3) The emission of a warning signal when the 15-min time limit of continuous cup application on the fetal scalp, is reached. No cup detachment occurred in any of the 15 vacuum-assisted deliveries, in which traction was kept below the adhesive force of the cup [44 lb (20 kg)], except in three cases, due to loss of negative pressure. In the remaining 15 tests, in which traction was greater than the adhesive force of the cup, "pull-offs" inevitably occurred. Furthermore, upon reaching the 15-min time limit of continuous cup application on the fetal cephalic model, a warning signal was emitted, as programmed. Conclusions We demonstrated that the electronically-controlled VE, with its distinctive pull-sensing handle, performs suitably for its intended purposes. The ability of the modernized device to decrease the incidence of cup detachment, secondary to the inadvertent application of excessive traction, may result in considerable safety, medico-legal and didactic advantages.

  19. Development of Subischial Prosthetic Sockets with Vacuum-Assisted Suspension for Highly Active Persons with Transfemoral Amputations

    DTIC Science & Technology

    2012-10-01

    materials to facilitate dissemination of this technique. 15. SUBJECT TERMS Transfemoral amputation, sub-ischial socket, prosthesis , vacuum-assisted...an appropriate mechanical pump to create suitable vacuum for suspension of the prosthesis ...sockets of highly active prosthesis users

  20. Effect of Rotation on Perineal Lacerations in Forceps-Assisted Vaginal Deliveries

    PubMed Central

    Bradley, Megan S.; Kaminski, Robert J.; Streitman, David C.; Dunn, Shannon L.; Krans, Elizabeth E.

    2013-01-01

    Objective To determine the difference in the rates of severe perineal lacerations between forceps-assisted vaginal deliveries in the occiput-posterior (OP) position compared with forceps-assisted vaginal deliveries in which the fetal head was rotated to occiput anterior (OA) prior to delivery. Methods We studied a retrospective cohort of 148 women who had a forceps-assisted vaginal delivery from 2008–2011 at the University of Pittsburgh. Mild perineal lacerations were defined as first or second degree, and severe lacerations were defined as third or fourth degree. Chi-square and t tests were used for bivariate and logistic regression was used for multivariable analyses. P<.05 was considered statistically significant. Results Of 148 forceps-assisted deliveries, 81 delivered OA after either manual or forceps rotation, 10 delivered in the OP or occiput-transverse position after an unsuccessful rotation, and 57 delivered OP without attempted rotation. No significant differences were found between demographic, obstetric and neonatal characteristics of the groups. Overall, 86 (67.7%) women had mild lacerations and 41 (32.3%) had severe lacerations. A significantly greater rate of severe perineal lacerations were found in the OP nonrotated compared with the rotated group (43.4% compared with 24.3%; P=.02). In multivariable analyses, adjusted for age, race, insurance, body mass index, gestational age, parity, episiotomy and neonatal weight, forceps-assisted vaginal delivery in the OP position without rotation remained significantly more likely to be associated with severe lacerations (OR 3.67; 95% CI 1.42–9.47). Conclusion Forceps-assisted vaginal delivery after rotation of an OP position to an OA position is associated with less severe maternal perineal trauma than forceps-assisted delivery in the OP position. PMID:23743462

  1. Effect of rotation on perineal lacerations in forceps-assisted vaginal deliveries.

    PubMed

    Bradley, Megan S; Kaminski, Robert J; Streitman, David C; Dunn, Shannon L; Krans, Elizabeth E

    2013-07-01

    To determine the difference in the rates of severe perineal lacerations between forceps-assisted vaginal deliveries in the occiput-posterior position compared with forceps-assisted vaginal deliveries in which the fetal head was rotated to occiput-anterior before delivery. We studied a retrospective cohort of 148 women who had a forceps-assisted vaginal delivery from 2008 to 2011 at the University of Pittsburgh. Mild perineal lacerations were defined as first or second degree, and severe lacerations were defined as third or fourth degree. χ and t tests were used for bivariate and logistic regression was used for multivariable analyses. P<.05 was considered statistically significant. Of 148 forceps-assisted deliveries, 81 delivered occiput-anterior after either manual or forceps rotation, 10 delivered in the occiput-posterior or occiput-transverse position after an unsuccessful rotation, and 57 delivered occiput-posterior without attempted rotation. No significant differences were found among demographic, obstetric, and neonatal characteristics of the groups. Overall, 86 (67.7%) women had mild lacerations and 41 (32.3%) had severe lacerations. A significantly greater rate of severe perineal lacerations was found in the occiput-posterior nonrotated compared with the rotated group (43.4% compared with 24.3%; P=.02). In multivariable analyses, adjusted for age, race, insurance, body mass index, gestational age, parity, episiotomy, and birth weight, forceps-assisted vaginal delivery in the occiput-posterior position without rotation remained significantly more likely to be associated with severe lacerations (odds ratio 3.67, 95% confidence interval 1.42-9.47). Forceps-assisted vaginal delivery after rotation of an occiput-posterior position to an occiput-anterior position is associated with less severe maternal perineal trauma than forceps-assisted delivery in the occiput-posterior position. II.

  2. Development of Subischial Prosthetic Sockets with Vacuum-Assisted Suspension for Highly Active Persons with Transfemoral Amputations

    DTIC Science & Technology

    2014-10-01

    Award Number: W81XWH-10-1-0744 TITLE: Development of Subischial Prosthetic Sockets with Vacuum...REPORT TYPE Annual 3. DATES COVERED 15 Sep 2013 – 14 Sep 2014 4. TITLE AND SUBTITLE Development of Subischial Prosthetic Sockets with Vacuum...to develop a highly flexible sub-ischial prosthetic socket with assisted-vacuum suspension for highly active persons with transfemoral amputation. The

  3. Protection of polyphenols in blueberry juice by vacuum-assisted block freeze concentration.

    PubMed

    Orellana-Palma, Patricio; Petzold, Guillermo; Pierre, Lissage; Pensaben, José Manuel

    2017-11-01

    Block freeze concentration allows produces high-quality cryoconcentrates with important protection of valuable components from fresh fruit juices. The aim of this study was to investigate the use of vacuum-assisted block freeze concentration under different experimental conditions to protect polyphenols in the elaboration of concentrated blueberry juice. Fresh blueberry juice was radial or unidirectional frozen at -20 and -80 °C for 12 h and vacuum process was performed at 80 kPa during 120 min. Results showed a significant solute increased in the concentrated fraction in all treatments, and the best treatment was - 20 °C/unidirectional with a value of ≈63 °Brix, equivalent to an increase of 3.8 times in the total polyphenol content (76% of retention). The color of concentrated samples was darker than the initial sample, with ΔE* values of >25 CIELab units in all treatments. The vacuum-assisted block freeze concentrations was an effective technology for protecting polyphenols and obtain a concentrated with a higher concentration of solids from blueberry juice, as well as interesting values of process parameters. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Vacuum-assisted fluid flow in microchannels to pattern substrates and cells.

    PubMed

    Shrirao, Anil B; Kung, Frank H; Yip, Derek; Cho, Cheul H; Townes-Anderson, Ellen

    2014-09-01

    Substrate and cell patterning are widely used techniques in cell biology to study cell-to-cell and cell-substrate interactions. Conventional patterning techniques work well only with simple shapes, small areas and selected bio-materials. This paper describes a method to distribute cell suspensions as well as substrate solutions into complex, long, closed (dead-end) polydimethylsiloxane (PDMS) microchannels using negative pressure. Our method builds upon a previous vacuum-assisted method used for micromolding (Jeon et al 1999 Adv. Mater 11 946) and successfully patterned collagen-I, fibronectin and Sal-1 substrates on glass and polystyrene surfaces, filling microchannels with lengths up to 120 mm and covering areas up to 13 × 10 mm(2). Vacuum-patterned substrates were subsequently used to culture mammalian PC12 and fibroblast cells and amphibian neurons. Cells were also patterned directly by injecting cell suspensions into microchannels using vacuum. Fibroblast and neuronal cells patterned using vacuum showed normal growth and minimal cell death indicating no adverse effects of vacuum on cells. Our method fills reversibly sealed PDMS microchannels. This enables the user to remove the PDMS microchannel cast and access the patterned biomaterial or cells for further experimental purposes. Overall, this is a straightforward technique that has broad applicability for cell biology.

  5. Vacuum-assisted Fluid Flow in Microchannels to Pattern Substrates and Cells

    PubMed Central

    Shrirao, Anil B.; Kung, Frank H.; Yip, Derek; Cho, Cheul H.; Townes-Anderson, Ellen

    2014-01-01

    Substrate and cell patterning are widely used techniques in cell biology to study cell-to-cell and cell-to-substrate interactions. Conventional patterning techniques work well only with simple shapes, small areas and selected bio-materials. This paper describes a method to distribute cell suspensions as well as substrate solutions into complex, long, closed (dead-end) polydimethylsiloxane (PDMS) microchannels using negative pressure. Our method builds upon a previous vacuum-assisted method used for micromolding (Jeon, Choi et al. 1999) and successfully patterned collagen-I, fibronectin and Sal-1 substrates on glass and polystyrene surfaces, filling microchannels with lengths up to 120 mm and covering areas up to 13 × 10 mm2. Vacuum-patterned substrates were subsequently used to culture mammalian PC12 and fibroblast cells and amphibian neurons. Cells were also patterned directly by injecting cell suspensions into microchannels using vacuum. Fibroblast and neuronal cells patterned using vacuum showed normal growth and minimal cell death indicating no adverse effects of vacuum on cells. Our method fills reversibly sealed PDMS microchannels. This enables the user to remove the PDMS microchannel cast and access the patterned biomaterial or cells for further experimental purposes. Overall, this is a straightforward technique that has broad applicability for cell biology. PMID:24989641

  6. [Caesarean section with vacuum extraction of the head].

    PubMed

    Dimitrov, A; Pavlova, E; Krŭsteva, K; Nikolov, A

    2008-01-01

    The aim of the study is to investigate the benefits and the limits in using the soft cup vacuum extractor on the fetal scalp during the caesarean section. The prospective study includes 19 cases of caesarean sections (group A), with vacuum assisted delivery using the soft cup vacuum extractor on the fetal scalp (diameter 6 cm) and 25 cases (group B) of caesarean sections with usual, manual extraction of the head assisted by fundal compression. All of the patients had undergone a planned caesarean section on term in absence of uterine activity and preserved amniotic membranes. Our results doesn't show differences in the Apgar score on the first and 5-th minute in the newborns of the two groups. The duration of the scalp traction was significantly shorter (30 +/- 4 sec) in comparison to the classical manual extraction (53 +/- 21 sec). The mean duration for applying the vacuum cup was 10 sec and 25 sec for tractions. The total blood loose and total duration of the caesarean sections were shorter than in the control group. The applied traction with the vacuum cup was sufficient for head extraction and there was no need for additional fundal compression. In conclusion we consider that the extraction of the fetal head in high position in caesarean section with vacuum extractor is an easy, non traumatic and rapid method which can put away the need of rough and prolonged fundal compression and its consequences.

  7. Laser assisted drug delivery: a review of an evolving technology.

    PubMed

    Sklar, Lindsay R; Burnett, Christopher T; Waibel, Jill S; Moy, Ronald L; Ozog, David M

    2014-04-01

    Topically applied drugs have a relatively low cutaneous bioavailability. This article reviews the existing applications of laser assisted drug delivery, a means by which the permeation of topically applied agents can be enhanced into the skin. The existing literature suggests that lasers are a safe and effective means of enhancing the delivery of topically applied agents through the skin. The types of lasers most commonly studied in regards to drug delivery are the carbon dioxide (CO2 ) and erbium:yttrium-aluminum-garnet (Er:YAG) lasers. Both conventional ablative and fractional ablative modalities have been utilized and are summarized herein. The majority of the existing studies on laser assisted drug delivery have been performed on animal models and additional human studies are needed. Laser assisted drug delivery is an evolving technology with potentially broad clinical applications. Multiple studies demonstrate that laser pretreatment of the skin can increase the permeability and depth of penetration of topically applied drug molecules for both local cutaneous and systemic applications. © 2014 Wiley Periodicals, Inc.

  8. Vacuum-Assisted, Constant-Force Exercise Device

    NASA Technical Reports Server (NTRS)

    Hansen, Christopher P.; Jensen, Scott

    2006-01-01

    The vacuum-assisted, constant-force exercise device (VAC-FED) has been proposed to fill a need for a safe, reliable exercise machine that would provide constant loads that could range from 20 to 250 lb (0.09 to 1.12 kN) with strokes that could range from 6 to 36 in. (0.15 to 0.91 m). The VAC-FED was originally intended to enable astronauts in microgravity to simulate the lifting of free weights, but it could just as well be used on Earth for simulated weight lifting and other constant-force exercises. Because the VAC-FED would utilize atmospheric/vacuum differential pressure instead of weights to generate force, it could weigh considerably less than either a set of free weights or a typical conventional exercise machine based on weights. Also, the use of atmospheric/ vacuum differential pressure to generate force would render the VAC-FED inherently safer, relative to free weights and to conventional exercise machines that utilize springs to generate forces. The overall function of the VAC-FED would be to generate a constant tensile force in an output cable, which would be attached to a bar, handle, or other exercise interface. The primary force generator in the VAC-FED would be a piston in a cylinder. The piston would separate a volume vented to atmosphere at one end of the cylinder from an evacuated volume at the other end of the cylinder (see figure). Hence, neglecting friction at the piston seals, the force generated would be nearly constant equal to the area of the piston multiplied by the atmospheric/vacuum differential pressure. In the vented volume in the cylinder, a direct-force cable would be looped around a pulley on the piston, doubling the stroke and halving the tension. One end of the direct-force cable would be anchored to a cylinder cap; the other end of the direct-force cable would be wrapped around a variable-ratio pulley that would couple tension to the output cable. As its name suggests, the variable-ratio pulley would contain a mechanism that

  9. Development of Sub-Ischial Prosthetic Sockets with Vacuum-Assisted Suspension for Highly Active Persons with Transfemoral Amputations

    DTIC Science & Technology

    2013-10-01

    15. SUBJECT TERMS Transfemoral amputation, sub-ischial socket, prosthesis , vacuum-assisted suspension 16. SECURITY CLASSIFICATION OF: 17...vacuum for suspension of the prosthesis ...14 Task 6 Determine range of volumes to be evacuated from transfemoral sockets of highly active prosthesis users

  10. Fetal head circumference, operative delivery, and fetal outcomes: a multi-ethnic population-based cohort study

    PubMed Central

    2013-01-01

    Background Operative delivery procedures, such as primary cesarean section, vacuum-assisted, and forceps-assisted vaginal delivery increase maternal and fetal morbidity, and the cost of care. We evaluated whether large fetal head circumference (FHC) independently increases risk of such interventions, as well as fetal distress or low Apgar score, in anatomically normal infants. Methods We conducted a population-based retrospective cohort study using Washington State birth certificate data. We included singleton, term infants born to nulliparous mothers from 2003–2009. We compared mode of delivery and fetal outcomes in 10,750 large-FHC (37-41 cm) infants relative to 10,750 average-FHC (34 cm) infants, frequency matched by birth-year. Results Large-FHC infants were nearly twice as likely to be delivered by primary cesarean section as average-FHC infants (unadjusted relative risk [RR] 1.84, 95% confidence interval [CI]: 1.77, 1.92). The RR for primary cesarean section associated with large-FHC was largest for mothers aged 19 years or less (RR 2.28; 95% CI: 1.99, 2.61), and smallest for mothers aged 35 years or greater (RR 1.51; 95% CI: 1.37, 1.66) [test of homogeneity, p < 0.001]. Large-FHC infants were at increased risk of vacuum-assisted vaginal delivery (RR 1.55; 95% CI: 1.43, 1.69), and forceps-assisted vaginal delivery (RR 1.61; 95% CI: 1.32, 1.97). There was no difference in risk of fetal distress (RR 0.97; 95% CI: 0.89, 1.07) for large-FHC versus average-FHC infants. Risk estimates were unaffected by adjustment for potential confounders. Conclusions Nulliparous mothers of large-FHC infants are at increased risk of primary cesarean section, vacuum-assisted and forceps-assisted vaginal delivery relative to mothers of average-FHC infants. Maternal age modifies the association between FHC and primary cesarean section. PMID:23651454

  11. The benefits of using a vacuum-assisted socket system to improve balance and gait in elderly transtibial amputees.

    PubMed

    Samitier, C Beatriz; Guirao, Lluis; Costea, Maria; Camós, Josep M; Pleguezuelos, Eulogio

    2016-02-01

    Lower limb amputation leads to impaired balance, ambulation, and transfers. Proper fit of the prosthesis is a determining factor for successful ambulation. Vacuum-assisted socket systems extract air from the socket, which decreases pistoning and probability of soft-tissue injuries and increases proprioception and socket comfort. To investigate the effect of vacuum-assisted socket system on transtibial amputees' performance-based and perceived balance, transfers, and gait. Quasi-experimental before-and-after study. Subjects were initially assessed using their prosthesis with the regular socket and re-evaluated 4 weeks after fitting including the vacuum-assisted socket system. We evaluated the mobility grade using Medicare Functional Classification Level, Berg Balance Scale, Four Square Step Test, Timed Up and Go Test, the 6-Min Walk Test, the Locomotor Capabilities Index, Satisfaction with Prosthesis (SAT-PRO questionnaire), and Houghton Scale. A total of 16 unilateral transtibial dysvascular amputees, mean age 65.12 (standard deviation = 10.15) years. Using the vacuum-assisted socket system, the patients significantly improved in balance, gait, and transfers: scores of the Berg Balance Scale increased from 45.75 (standard deviation = 6.91) to 49.06 (standard deviation = 5.62) (p < 0.01), Four Square Step Test decreased from 18.18 (standard deviation = 3.84) s to 14.97 (3.9) s (p < 0.01), Timed Up and Go Test decreased from 14.3 (standard deviation = 3.29) s to 11.56 (2.46) s (p < 0.01). The distance walked in the 6-Min Walk Test increased from 288.53 (standard deviation = 59.57) m to 321.38 (standard deviation = 72.81) m (p < 0.01). Vacuum-assisted socket systems are useful for improving balance, gait, and transfers in over-50-year-old dysvascular transtibial amputees. This study gives more insight into the use of vacuum-assisted socket systems to improve elderly transtibial dysvascular amputees

  12. Evaluation of delivery options for second-stage events.

    PubMed

    Bailit, Jennifer L; Grobman, William A; Rice, Madeline Murguia; Wapner, Ronald J; Reddy, Uma M; Varner, Michael W; Thorp, John M; Caritis, Steve N; Iams, Jay D; Saade, George; Rouse, Dwight J; Tolosa, Jorge E

    2016-05-01

    Cesarean delivery in the second stage of labor is common, whereas the frequency of operative vaginal delivery has been declining. However, data comparing outcomes for attempted operative vaginal delivery vs cesarean in the second stage are scant. Previous studies that examine operative vaginal delivery have compared it to a baseline risk of complications from a spontaneous vaginal delivery and cesarean delivery. However, when a woman has a need for intervention in the second stage, spontaneous vaginal delivery is not an option she or the provider can choose. Thus, the appropriate clinical comparison is cesarean vs operative vaginal delivery. Our objective was to compare outcomes by the first attempted operative delivery (vacuum, forceps vs cesarean delivery) in patients needing second-stage assistance at a fetal station of +2 or below. We conducted secondary analysis of an observational obstetric cohort in 25 academically affiliated US hospitals over a 3-year period. A subset of ≥37 weeks, nonanomalous, vertex, singletons, with no prior vaginal delivery who reached a station of +2 or below and underwent an attempt at an operative delivery were included. Indications included for operative delivery were: failure to descend, nonreassuring fetal status, labor dystocia, or maternal exhaustion. The primary outcomes included a composite neonatal outcome (death, fracture, length of stay ≥3 days beyond mother's, low Apgar, subgaleal hemorrhage, ventilator support, hypoxic encephalopathy, brachial plexus injury, facial nerve palsy) and individual maternal outcomes (postpartum hemorrhage, third- and fourth-degree tears [severe lacerations], and postpartum infection). Outcomes were examined by the 3 attempted modes of delivery. Odds ratios (OR) were calculated for primary outcomes adjusting for confounders. Final mode of delivery was quantified. In all, 2531 women met inclusion criteria. No difference in the neonatal composite outcome was observed between groups. Vacuum

  13. Evaluation of delivery options for second stage events

    PubMed Central

    Bailit, Jennifer L.; Grobman, William A.; Rice, Madeline Murguia; Wapner, Ronald J.; Reddy, Uma M.; Varner, Michael W.; Thorp, John M.; Caritis, Steve N.; Iams, Jay D.; Saade, George; Rouse, Dwight J.; Tolosa, Jorge E.

    2015-01-01

    Background Cesarean delivery in the second stage of labor is common, whereas the frequency of operative vaginal delivery has been declining. However, data comparing outcomes for attempted operative vaginal delivery in the second stage versus cesarean in the second stage are scant. Previous studies that examine operative vaginal delivery have compared it to a baseline risk of complications from a spontaneous vaginal delivery and cesarean delivery. However, when a woman has a need for intervention in the second stage, spontaneous vaginal delivery is not an option she or the provider can choose. Thus, the appropriate clinical comparison is cesarean versus operative vaginal delivery. Objective Our objective was to compare outcomes by the first attempted operative delivery (vacuum, forceps versus cesarean delivery) in patients needing second stage assistance at a fetal station of +2 or below. Study Design Secondary analysis of an observational obstetric cohort in 25 academically-affiliated U.S. hospitals over a three-year period. A subset of ≥37 weeks, non-anomalous, vertex, singletons, with no prior vaginal delivery who reached a station of +2 or below and underwent an attempt at an operative delivery were included. Indications included for operative delivery were: failure to descend, non-reassuring fetal status, labor dystocia or maternal exhaustion. The primary outcomes included a composite neonatal outcome (death, fracture, length of stay ≥3 days beyond mother’s, low Apgar, subgaleal hemorrhage, ventilator support, hypoxic encephalopathy, brachial plexus injury, facial nerve palsy) and individual maternal outcomes (postpartum hemorrhage, third and fourth degree tears [severe lacerations], and postpartum infection). Outcomes were examined by the three attempted modes of delivery. Odds ratios were calculated for primary outcomes adjusting for confounders. Final mode of delivery was quantified. Results 2531 women met inclusion criteria. Vacuum attempt was

  14. Integrated cooling-vacuum-assisted 1540-nm erbium:glass laser is effective in treating mild-to-moderate acne vulgaris.

    PubMed

    Politi, Y; Levi, A; Enk, C D; Lapidoth, M

    2015-12-01

    Acne treatment by a mid-infrared laser may be unsatisfactory due to deeply situated acne-affected sebaceous glands which serve as its target. Skin manipulation by vacuum and contact cooling may improve laser-skin interaction, reduce pain sensation, and increase overall safety and efficacy. To evaluate the safety and efficacy of acne treatment using an integrated cooling-vacuum-assisted 1540-nm erbium:glass laser, a prospective interventional study was conducted. It included 12 patients (seven men and five women) suffering from mild-to-moderate acne vulgaris. The device utilizes a mid-infrared 1540-nm laser (Alma Lasers Ltd. Caesarea, Israel), which is integrated with combined cooling-vacuum-assisted technology. An acne lesion is initially manipulated upon contact by a vacuum-cooling-assisted tip, followed by three to four stacked laser pulses (500-600 mJ, 4 mm spot size, and frequency of 2 Hz). Patients underwent four to six treatment sessions with a 2-week interval and were followed-up 1 and 3 months after the last treatment. Clinical photographs were taken by high-resolution digital camera before and after treatment. Clinical evaluation was performed by two independent dermatologists, and results were graded on a scale of 0 (exacerbation) to 4 (76-100 % improvement). Patients' and physicians' satisfaction was also recorded. Pain perception and adverse effects were evaluated as well. All patients demonstrated a moderate to significant improvement (average score of 3.6 and 2.0 within 1 and 3 months, respectively, following last treatment session). No side effects, besides a transient erythema, were observed. Cooling-vacuum-assisted 1540-nm laser is safe and effective for the treatment of acne vulgaris.

  15. Antibiotic prophylaxis for operative vaginal delivery.

    PubMed

    Liabsuetrakul, Tippawan; Choobun, Thanapan; Peeyananjarassri, Krantarat; Islam, Q Monir

    2014-10-13

    Vacuum and forceps assisted vaginal deliveries are reported to increase the incidence of postpartum infections and maternal readmission to hospital compared to spontaneous vaginal delivery. Prophylactic antibiotics may be prescribed to prevent these infections. However, the benefit of antibiotic prophylaxis for operative vaginal deliveries is still unclear. To assess the effectiveness and safety of antibiotic prophylaxis in reducing infectious puerperal morbidities in women undergoing operative vaginal deliveries including vacuum or forceps deliveries, or both. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (31 August 2014). All randomised trials comparing any prophylactic antibiotic regimens with placebo or no treatment in women undergoing vacuum or forceps deliveries were eligible. Participants were all pregnant women without evidence of infections or other indications for antibiotics of any gestational age undergoing vacuum or forceps delivery for any indications. Interventions were any antibiotic prophylaxis (any dosage regimen, any route of administration or at any time during delivery or the puerperium) compared with either placebo or no treatment. Two review authors assessed trial eligibility and methodological quality. Two review authors extracted the data independently using prepared data extraction forms. Any discrepancies were resolved by discussion and a consensus reached through discussion with all review authors. For this update, we assessed methodological quality of the one included trial using the standard Cochrane criteria and the GRADE approach. We calculated the risk ratio (RR) and mean difference (MD) using a fixed-effect model and all the review authors interpreted and discussed the results. One trial, involving 393 women undergoing either vacuum or forceps deliveries, was included. This trial identified only two out of the nine outcomes specified in this review. It reported seven women with endomyometritis in the

  16. Antibiotic prophylaxis for operative vaginal delivery.

    PubMed

    Liabsuetrakul, T; Choobun, T; Peeyananjarassri, K; Islam, M

    2004-01-01

    Vacuum and forceps assisted vaginal deliveries are reported to increase the incidence of postpartum infections and maternal readmission to hospital compared to spontaneous vaginal delivery. Prophylactic antibiotics are prescribed to prevent these infections. However, the benefit of antibiotic prophylaxis for operative vaginal deliveries is still unclear. To assess the effectiveness and safety of antibiotic prophylaxis in reducing infectious puerperal morbidities in women undergoing operative vaginal deliveries including vacuum and/or forceps deliveries. We searched the Cochrane Pregnancy and Childbirth Group trials register (November 2003), the Cochrane Central Register of Controlled Trials (The Cochrane Library, Issue 4, 2003) and MEDLINE (1966 to November 2003). All randomised trials comparing any prophylactic antibiotic regimens with placebo or no treatment in women undergoing vacuum or forceps deliveries were eligible. Participants were all pregnant women without evidence of infections or other indications for antibiotics of any gestational age undergoing vacuum or forceps delivery for any indications. Interventions were any antibiotic prophylaxis (any dosage regimen, any route of administration or at any time during delivery or the puerperium) compared with either placebo or no treatment. Four reviewers assessed trial eligibility and methodological quality. Two reviewers extracted the data independently using prepared data extraction forms. Any discrepancies were resolved by discussion and a consensus reached through discussion with all reviewers. We assessed methodological quality of the included trial using the standard Cochrane criteria and the CONSORT statement of randomised controlled trials. We calculated the relative risks using a fixed effect model and all the reviewers interpreted and discussed the results. One trial, involving 393 women undergoing either vacuum or forceps deliveries, was included. This trial identified only two out of the nine

  17. Flat epithelial atypia in directional vacuum-assisted biopsy of breast microcalcifications: surgical excision may not be necessary.

    PubMed

    McCroskey, Zulfia; Sneige, Nour; Herman, Carolyn R; Miller, Ross A; Venta, Luz A; Ro, Jae Y; Schwartz, Mary R; Ayala, Alberto G

    2018-02-21

    The aim of this study was to analyze the clinicopathological features of patients with flat epithelial atypia, diagnosed in directional vacuum-assisted biopsy targeting microcalcifications, to identify upgrade rate to in situ ductal or invasive breast carcinoma, and determine factors predicting carcinoma in the subsequent excision. We retrospectively evaluated the histological, clinical, and mammographic features of 69 cases from 65 women, with directional vacuum-assisted biopsy-diagnosed flat epithelial atypia with or without atypical ductal hyperplasia or atypical lobular hyperplasia, which underwent subsequent surgical excision. The extent and percentage of microcalcifications sampled by directional vacuum-assisted biopsy were evaluated by mammography. All biopsy and surgical excision slides were reviewed. The age of the women ranged from 40 to 85 years (mean 57 years). All patients presented with mammographically detected microcalcifications only, except in one case that had associated architectural distortion. Extent of calcifications ranged from <1 cm (n = 47), 1-3 cm (n = 15) to > 3 cm (n = 6), and no measurement (n = 1). A mean of 11 cores (range 6-25) was obtained from each lesion. Post-biopsy mammogram revealed >90% removal of calcifications in 81% of cases. Pure flat epithelial atypia represented nearly two-thirds of directional vacuum-assisted biopsy specimens (n = 43, 62%), while flat epithelial atypia coexisted with atypical ductal hyperplasia (18 cases, 26%), or atypical lobular hyperplasia (8 cases, 12%). Upon excision, none of the cases were upgraded to in situ ductal or invasive breast cancer. In one case, however, an incidental, tubular carcinoma (4 mm) was found away from biopsy site. Excluding this case, the upgrade rate was 0%. Our study adds to the growing evidence that diagnosis of flat epithelial atypia on directional vacuum-assisted biopsy for microcalcifications as the only imaging finding is not associated

  18. Ultrasound-Guided Core-Needle Versus Vacuum-Assisted Breast Biopsy: A Cost Analysis Based on the American Society of Breast Surgeons' Mastery of Breast Surgery Registry.

    PubMed

    Grady, Ian; Vasquez, Tony; Tawfik, Sara; Grady, Sean

    2017-03-01

    To evaluate the cost-efficacy of vacuum-assisted ultrasound-guided breast biopsy instruments compared to ultrasound-guided 14-gauge spring-loaded core-needle biopsy. The American Society of Breast Surgeons' Mastery of Breast Surgery Registry was reviewed. Biopsy findings, any rebiopsy, and the instrument used were abstracted for 31,451 ultrasound-guided biopsy procedures performed between 2001 and July 2014. Rates of cancer diagnosis and rebiopsy were calculated for each instrument. A linear mathematical model was developed to calculate total cost per cancer diagnosis, including procedural costs and the costs of any additional surgical rebiopsy procedures. Mean cost per cancer diagnosis with confidence limits was then determined for 14-gauge spring-loaded core-needle biopsy and 14 different vacuum-assisted instruments. For 14-gauge spring-loaded core-needle biopsy, mean cost per cancer diagnosis was $4346 (4327-$4366). For the vacuum-assisted instruments, mean cost per cancer diagnosis ranged from a low of $3742 ($3732-$3752) to a high of $4779 ($4750-$4809). Vacuum-assisted instruments overall were more cost-effective than core with a mean cost per cancer diagnosis of $4052 ($4038-$4067) (p < 0.05). Tethered vacuum-assisted instruments performed best with a mean cost per cancer diagnosis of $3978 ($3964-$3991) (p < 0.05). Nontethered devices had a mean cost per cancer diagnosis of $4369 ($4350-$4388), a result no better than core (p < 0.05). Ultrasound-guided vacuum-assisted breast biopsy had a lower mean cost per cancer diagnosis than 14-gauge spring-loaded core-needle biopsy. This advantage was only seen in tethered vacuum-assisted instruments. Within device families, larger instruments tended to outperform smaller instruments.

  19. Surface oxidation of GaN(0001): Nitrogen plasma-assisted cleaning for ultrahigh vacuum applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gangopadhyay, Subhashis; Schmidt, Thomas, E-mail: tschmidt@ifp.uni-bremen.de; Kruse, Carsten

    The cleaning of metal-organic vapor-phase epitaxial GaN(0001) template layers grown on sapphire has been investigated. Different procedures, performed under ultrahigh vacuum conditions, including degassing and exposure to active nitrogen from a radio frequency nitrogen plasma source have been compared. For this purpose, x-ray photoelectron spectroscopy, reflection high-energy electron diffraction, and scanning tunneling microscopy have been employed in order to assess chemical as well as structural and morphological surface properties. Initial degassing at 600 °C under ultrahigh vacuum conditions only partially eliminates the surface contaminants. In contrast to plasma assisted nitrogen cleaning at temperatures as low as 300 °C, active-nitrogen exposure at temperaturesmore » as high as 700 °C removes the majority of oxide species from the surface. However, extended high-temperature active-nitrogen cleaning leads to severe surface roughening. Optimum results regarding both the removal of surface oxides as well as the surface structural and morphological quality have been achieved for a combination of initial low-temperature plasma-assisted cleaning, followed by a rapid nitrogen plasma-assisted cleaning at high temperature.« less

  20. Antibiotic prophylaxis for operative vaginal delivery.

    PubMed

    Liabsuetrakul, Tippawan; Choobun, Thanapan; Peeyananjarassri, Krantarat; Islam, Q Monir

    2017-08-05

    Vacuum and forceps assisted vaginal deliveries are reported to increase the incidence of postpartum infections and maternal readmission to hospital compared to spontaneous vaginal delivery. Prophylactic antibiotics may be prescribed to prevent these infections. However, the benefit of antibiotic prophylaxis for operative vaginal deliveries is still unclear. To assess the effectiveness and safety of antibiotic prophylaxis in reducing infectious puerperal morbidities in women undergoing operative vaginal deliveries including vacuum or forceps deliveries, or both. We searched Cochrane Pregnancy and Childbirth's Trials Register (12 July 2017), ClinicalTrials.gov, the WHO International Clinical Trials Registry Platform (ICTRP) (12 July 2017) and reference lists of retrieved studies. All randomised trials comparing any prophylactic antibiotic regimens with placebo or no treatment in women undergoing vacuum or forceps deliveries were eligible. Participants were all pregnant women without evidence of infections or other indications for antibiotics of any gestational age undergoing vacuum or forceps delivery for any indications. Interventions were any antibiotic prophylaxis (any dosage regimen, any route of administration or at any time during delivery or the puerperium) compared with either placebo or no treatment. Two review authors assessed trial eligibility and methodological quality. Two review authors extracted the data independently using prepared data extraction forms. Any discrepancies were resolved by discussion and a consensus reached through discussion with all review authors. We assessed methodological quality of the one included trial using the GRADE approach. One trial, involving 393 women undergoing either vacuum or forceps deliveries, was included. The trial compared the antibiotic intravenous cefotetan after cord clamping compared with no treatment. This trial reported only two out of the nine outcomes specified in this review. Seven women in the group

  1. Maternal and fetal outcomes after uterine fundal pressure in spontaneous and assisted vaginal deliveries.

    PubMed

    Furrer, Romana; Schäffer, Leonhard; Kimmich, Nina; Zimmermann, Roland; Haslinger, Christian

    2016-10-01

    This study aimed to evaluate maternal and fetal outcomes after uterine fundal pressure (UFP) in spontaneous and assisted vaginal deliveries. In a retrospective cohort study, 9743 singleton term deliveries with cephalic presentation were analyzed from 2004 to 2013. Spontaneous and assisted vaginal deliveries were analyzed separately with and without the application of UFP. Odds ratios were adjusted in a multivariate logistic regression analysis. Prevalence of UFP was 8.9% in spontaneous and 12.1% in assisted vaginal deliveries. UFP was associated with a higher incidence of shoulder dystocia in both spontaneous (adjusted odds ratio [adj. OR] 2.44, confidence interval [CI] 95% 1.23-4.84) and assisted vaginal deliveries (adj. OR 6.88 CI 95% 3.50-13.53). Fetal acidosis (arterial umbilical pH<7.2) was seen more often after the application of UFP in spontaneous vaginal deliveries (adj. OR 3.18, CI 95% 2.64-3.82) and assisted vaginal deliveries (adj. OR 1.59 CI 95% 1.17-2.16). The incidence of 5'-Apgar<7 (adj. OR 2.19 CI 95% 1.04-4.6) and 10'-Apgar<7 (adj. OR 3.04 CI 95% 1.17-7.88) was also increased after the application of UFP in spontaneous deliveries. A higher incidence of anal sphincter tears (AST) (adj. OR 46.25 CI 95% 11.78-181.6) in the UFP group of spontaneous deliveries was observed. UFP is associated with increased occurrence of shoulder dystocia and fetal acidosis. In spontaneous deliveries, the risk for lower Apgar scores after 5 and 10 min is increased, as well as the risk for AST.

  2. Vacuum-assisted closure as a surgical assistant in life-threatening necrotizing fasciitis in children

    PubMed Central

    Al-Subhi, FS; Zuker, RM; Cole, WG

    2010-01-01

    Necrotizing fasciitis is a severe soft tissue infection that can involve skin, subcutaneous fat, fascia and muscle. It can result in devastating sequelae including tissue necrosis, sepsis, toxic shock syndrome, cardiopulmonary collapse and death. To control rapidly spreading necrosis, early diagnosis and aggressive surgical treatment with extensive radical debridement of the affected areas is necessary, as well as systemic administration of broad-spectrum antimicrobials and, very often, intensive care support. The subatmospheric negative pressure dressing has been previously used in acute and complex wounds management. The concept of using vacuum-assisted closure dressing as another management component is presented in the current article. PMID:22131841

  3. Clinical impact of the disposable ventouse iCup® versus a metallic vacuum cup: a multicenter randomized controlled trial.

    PubMed

    Equy, Véronique; David-Tchouda, Sandra; Dreyfus, Michel; Riethmuller, Didier; Vendittelli, Françoise; Cabaud, Victoire; Langer, Bruno; Margier, Jennifer; Bosson, Jean-Luc; Schaal, Jean-Patrick

    2015-12-15

    Assisted vaginal delivery by vacuum extraction is frequent. Metallic resterilizible metallic vacuum cups have been routinely used in France. In the last few years a new disposable semi-soft vacuum extraction cup, the iCup, has been introduced. Our objective was to compare maternal and new-born outcomes between this disposable cup and the commonly used Drapier-Faure metallic cup. This was a multicenter prospective randomized controlled open clinical trial performed in the maternity units of five university hospitals and one community hospital in France from October 2009 to February 2013. We included consecutive eligible women with a singleton gestation of at least 37 weeks who required vacuum assisted delivery. Women were randomized to vacuum extraction using the iCup or usual Drapier-Faure metallic cup. The primary outcome was a composite criterion including both the risk of cup dysfunction and the most frequent maternal and neonatal harms: the use of other instruments after attempted vacuum extraction, caesarean section after attempted vacuum extraction, three detachments of the cup, caput succedaneum, cephalohaematoma, episiotomy and perineal tears. 335 women were randomized to the disposable cup and 333 to extraction using the metallic cup. There was no significant difference between the two groups for the primary outcome. However, failed instrumental delivery was more frequent in the disposable cup group, mainly due to detachment: 35.6 % vs 7.1 %, p < 0.0001. Conversely, perineal tears were more frequent in the metallic cup group, especially third or fourth grade perineal tears: 1.7 % versus 5.0 %, p = 0.003. There were no significant differences between the two groups concerning post-partum haemorrhage, transfer to a neonatal intensive care unit (NICU) or serious adverse events. While the disposable cup had more detachments and extraction failures than the standard metallic cup, this innovative disposable device had the advantage of fewer perineal

  4. Non-technical skills for obstetricians conducting forceps and vacuum deliveries: qualitative analysis by interviews and video recordings.

    PubMed

    Bahl, Rachna; Murphy, Deirdre J; Strachan, Bryony

    2010-06-01

    Non-technical skills are cognitive and social skills required in an operational task. These skills have been identified and taught in the surgical domain but are of particular relevance to obstetrics where the patient is awake, the partner is present and the clinical circumstances are acute and often stressful. The aim of this study was to define the non-technical skills of an operative vaginal delivery (forceps or vacuum) to facilitate transfer of skills from expert obstetricians to trainee obstetricians. Qualitative study using interviews and video recordings. The study was conducted at two university teaching hospitals (St. Michael's Hospital, Bristol and Ninewells Hospital, Dundee). Participants included 10 obstetricians and eight midwives identified as experts in conducting or supporting operative vaginal deliveries. Semi-structured interviews were carried out using routine clinical scenarios. The experts were also video recorded conducting forceps and vacuum deliveries in a simulation setting. The interviews and video recordings were transcribed verbatim and analysed using thematic coding. The anonymised data were independently coded by the three researchers and then compared for consistency of interpretation. The experts reviewed the coded data for respondent validation and clarification. The themes that emerged were used to identify the non-technical skills required for conducting an operative vaginal delivery. The final skills list was classified into seven main categories. Four categories (situational awareness, decision making, task management, and team work and communication) were similar to the categories identified in surgery. Three further categories unique to obstetrics were also identified (professional relationship with the woman, maintaining professional behaviour and cross-monitoring of performance). This explicitly defined skills taxonomy could aid trainees' understanding of the non-technical skills to be considered when conducting an operative

  5. Vacuum-assisted wound closure and mesh-mediated fascial traction for open abdomen therapy - a systematic review.

    PubMed

    Acosta, Stefan; Björck, Martin; Petersson, Ulf

    2017-01-01

    The aim of this paper was to review the literature on vacuum-assisted wound closure and mesh-mediated fascial traction (VAWCM) in open abdomen therapy. It was designed as systematic review of observational studies. A Pub Med, EMBASE and Cochrane search from 2007/01-2016/07 was performed combining the Medical Subject Headings "vacuum", "mesh-mediated fascial traction", "temporary abdominal closure", "delayed abdominal closure", "open abdomen", "abdominal compartment syndrome", "negative pressure wound therapy" or "vacuum assisted wound closure". Eleven original studies were found including patients numbering from 7 to 111. Six studies were prospective and five were retrospective. Nine studies were on mixed surgical (n = 9), vascular (n = 6) and trauma (n = 6) patients, while two were exclusively on vascular patients. The primary fascial closure rate per protocol varied from 80-100%. The time to closure of the open abdomen varied between 9-32 days. The entero-atmospheric fistula rate varied from 0-10.0%. The in-hospital survival rate varied from 57-100%. In the largest prospective study, the incisional hernia rate among survivors at 63 months of median follow-up was 54% (27/50), and 16 (33%) repairs out of 48 incisional hernias were performed throughout the study period. The study patients reported lower short form health survey (SF-36) scores than the mean reference population, mainly dependent on the prevalence of major co-morbidities. There was no difference in SF-36 scores or a modified ventral hernia pain questionnaire (VHPQ) at 5 years of follow up between those with versus those without incisional hernias. A high primary fascial closure rate can be achieved with the vacuum-assisted wound closure and meshmediated fascial traction technique in elderly, mainly non-trauma patients, in need of prolonged open abdomen therapy.

  6. Older individuals' experiences during the assistive technology device service delivery process.

    PubMed

    Gramstad, Astrid; Storli, Sissel Lisa; Hamran, Torunn

    2014-07-01

    Providing assistive technology devices to older individuals living in their ordinary homes is an important intervention to increase and sustain independence and to enable ageing at home. However, little is known about older individuals' experiences and needs in the assistive technology device (ATD) service delivery process. The purpose of this study was to investigate older individuals' experiences during the service delivery process of ATDs. Nine older individuals were interviewed three times each throughout the ATD service delivery process. The interviews were analysed within a hermeneutical phenomenological perspective. The results show that the service delivery process could be interpreted as an enigmatic journey and described using four themes: "hope and optimistic expectations", "managing after delivery or needing additional help", "having available help versus being abandoned", and "taking charge or putting up". The results emphasize the need for occupational therapists to maintain an individualized approach towards older clients throughout the service delivery process. The experiences of older individuals were diverse and related to expectations that were not necessarily articulated to the occupational therapist. The situation when the ATD is delivered to the client was highlighted by the clients as an important event with the potential to facilitate a successful service delivery process.

  7. Papilloma diagnosed at MRI-guided vacuum-assisted breast biopsy: is surgical excision still warranted?

    PubMed

    Brennan, Sandra B; Corben, Adriana; Liberman, Laura; Dershaw, D David; Brogi, Edi; Van Zee, Kimberly J; Morris, Elizabeth

    2012-10-01

    The objective of our study was to determine the frequency of cancer at surgery in breast lesions yielding papilloma at MRI-guided 9-gauge vacuum-assisted biopsy (VAB) and to determine whether any features are associated with cancer upgrade. For this study, 1487 MRI-guided vacuum-assisted biopsies performed from January 2004 to March 2011 were reviewed. Lesions yielding papilloma were identified and classified as papilloma with or without atypia. Surgical findings were reviewed to determine the cancer rate. Statistical analysis was performed and 95% CIs were calculated. Papilloma was identified in 75 of the 1487 MRI-guided vacuum-assisted biopsies (5%). These 75 papillomas occurred in 73 women with a median age of 49 years (age range, 27-70 years). Of the 75 papillomas, 25 (33%) had atypia and 50 (67%) did not on core needle biopsy. Subsequent surgery of 67 of the 75 papillomas (89%) yielded ductal carcinoma in situ (DCIS) in four (6%; 95% CI, 2-15%). Surgery yielded DCIS in two of 23 papillomas with atypia (9%; 95% CI, 1-28%) at MRI-guided VAB and in two of 44 papillomas without atypia (5%; 95% CI, 0.4-16%) at MRI-guided VAB; these cancer rates did not differ significantly (p=0.6). Postmenopausal status (p=0.04) and histologic size of less than 0.2 cm (p=0.04) had a significant association with the cancer upgrade rate. Papilloma with or without atypia was found in 5% of patients who underwent MRI-guided VAB during the study period. Surgery revealed cancer in 6%. DCIS was found at surgery in 9% of lesions yielding papilloma with atypia versus 5% of lesions yielding papilloma without atypia. For lesions yielding papilloma with or without atypia at MRI-guided VAB, surgical excision is warranted.

  8. Matrix Assisted Ionization Vacuum (MAIV), a New Ionization Method for Biological Materials Analysis Using Mass Spectrometry*

    PubMed Central

    Inutan, Ellen D.; Trimpin, Sarah

    2013-01-01

    The introduction of electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) for the mass spectrometric analysis of peptides and proteins had a dramatic impact on biological science. We now report that a wide variety of compounds, including peptides, proteins, and protein complexes, are transported directly from a solid-state small molecule matrix to gas-phase ions when placed into the vacuum of a mass spectrometer without the use of high voltage, a laser, or added heat. This ionization process produces ions having charge states similar to ESI, making the method applicable for high performance mass spectrometers designed for atmospheric pressure ionization. We demonstrate highly sensitive ionization using intermediate pressure MALDI and modified ESI sources. This matrix and vacuum assisted soft ionization method is suitable for the direct surface analysis of biological materials, including tissue, via mass spectrometry. PMID:23242551

  9. Transient cerebral hypoperfusion assisted intraarterial cationic liposome delivery to brain tissue

    PubMed Central

    Joshi, Shailendra; Singh-Moon, Rajinder P.; Wang, Mei; Chaudhuri, Durba B.; Holcomb, Mark; Straubinger, Ninfa L.; Bruce, Jeffrey N.; Bigio, Irving J.; Straubinger, Robert M.

    2014-01-01

    Object Transient cerebral hypoperfusion (TCH) has empirically been used to assist intraarterial (IA) drug delivery to brain tumors. Transient (< 3 min) reduction of cerebral blood flow (CBF) occurs during many neuro- and cardiovascular interventions and has recently been used to better target IA drugs to brain tumors. In the present experiments, we assessed whether the effectiveness of IA delivery of cationic liposomes could be improved by TCH. Methods Cationic liposomes composed of 1:1 DOTAP:PC (dioleoyl-trimethylammonium-propane:phosphatidylcholine) were administered to three groups of Sprague Dawley rats. In the first group, we tested the effect of blood flow reduction on IA delivery of cationic liposomes. In the second group, we compared TCH-assisted IA liposomal delivery vs. intravenous (IV) administration of the same dose. In the third group, we assessed retention of cationic liposomes in brain four hours after TCH assisted delivery. The liposomes contained a near infrared dye, DilC18(7), whose concentration could be measured in vivo by diffuse reflectance spectroscopy. Results IA injections of cationic liposomes during TCH increased their delivery approximately four-fold compared to injections during normal blood flow. Optical pharmacokinetic measurements revealed that relative to IV injections, IA injection of cationic liposomes during TCH produced tissue concentrations that were 100-fold greater. The cationic liposomes were retained in the brain tissue four hours after a single IA injection. There was no gross impairment of neurological functions in surviving animals. Conclusions Transient reduction in CBF significantly increased IA delivery of cationic liposomes in the brain. High concentrations of liposomes could be delivered to brain tissue after IA injections with concurrent TCH while none could be detected after IV injection. IA-TCH injections were well tolerated and cationic liposomes were retained for at least 4 hours after IA administration. These

  10. Ultrasound-assisted drug delivery for treatment of venous thrombosis: a case study.

    PubMed

    Marchiondo, Kathleen; Frink, Amber

    2008-01-01

    Ultrasound-assisted drug delivery is a relatively new medical intervention that combines low-intensity ultrasound waves with infusion of a thrombolytic agent directly into a thrombosed vein. Studies have demonstrated that clots are eradicated faster, more completely, and with fewer bleeding events with the use of ultrasound-assisted drug delivery for treatment of deep vein thrombosis compared to that of traditional therapies. Critical care nurses are responsible for preprocedure assessment and teaching and continuous monitoring of the patient during therapy for effectiveness and potential complications. An advantage of this technology from a nursing perspective is the minimal amount of time required for monitoring the drug delivery system, allowing greater focus on patient assessment and care.

  11. Laser-assisted drug delivery in dermatology: from animal models to clinical practice.

    PubMed

    Ali, Faisal R; Al-Niaimi, Firas

    2016-02-01

    Topical medicaments are the mainstay of the dermatologists' therapeutic arsenal. Laser-assisted drug delivery enhances the ability of topically applied medicaments to penetrate the skin. We discuss the mechanisms of laser-assisted drug delivery and animal models that have informed clinical practice. We review clinical studies that have employed laser-assisted drug delivery for a range of indications to date including non-melanoma skin cancer, vitiligo, scarring, vaccination, local anaesthesia, analgesia, viral warts, infantile haemangiomas and cosmetic uses. Studies thus far suggest that laser pre-treatment improves transepidermal absorption of topical agents and allows for a much deeper penetration of drugs than is possible with topical medicaments alone. This may allow more efficacious action of current treatments, such that conventional duration of treatment can be shortened or lower concentrations of active agents be used, potentially obviating side effects of treatment. The prospect of using laser technologies to facilitate transdermal vaccination and as an adjunct for inflammatory dermatoses and cosmetic indications remains in its infancy. As larger trials are published, involving greater numbers of patients and utilising various laser and topical medicament parameters, we will enhance our understanding of this nascent modality of treatment delivery.

  12. 14 CFR 29.1433 - Vacuum systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Equipment Miscellaneous Equipment § 29.1433 Vacuum systems. (a... the discharge lines from the vacuum air pump when the delivery temperature of the air becomes unsafe. (b) Each vacuum air system line and fitting on the discharge side of the pump that might contain...

  13. 14 CFR 25.1433 - Vacuum systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Miscellaneous Equipment § 25.1433 Vacuum systems. There... discharge lines from the vacuum air pump when the delivery temperature of the air becomes unsafe. [Doc. No...

  14. Assistive Technology Service Delivery in Rural School Districts

    ERIC Educational Resources Information Center

    Ault, Melinda Jones; Bausch, Margaret E.; Mclaren, Elizabeth M.

    2013-01-01

    Little is known about the implementation of assistive technology (AT) services for students in rural areas. This study investigated the AT service delivery in 10 rural districts across six states. The results indicated that students use AT across functional areas, but considerably fewer number of devices than do those not living in rural areas. AT…

  15. Post-Vacuum-Assisted Stereotactic Core Biopsy Clip Displacement: A Comparison Between Commercially Available Clips and Surgical Clip.

    PubMed

    Yen, Peggy; Dumas, Sandra; Albert, Arianne; Gordon, Paula

    2018-02-01

    The placement of localization clips following percutaneous biopsy is a standard practice for a variety of situations. Subsequent clip displacement creates challenges for imaging surveillance and surgical planning, and may cause confusion amongst radiologists and between surgeons and radiologists. Many causes have been attributed for this phenomenon including the commonly accepted "accordion effect." Herein, we investigate the performance of a low cost surgical clip system against 4 commercially available clips. We retrospectively reviewed 2112 patients who underwent stereotactic vacuum-assisted core biopsy followed by clip placement between January 2013 and June 2016. The primary performance parameter compared was displacement >10 mm following vacuum-assisted stereotactic core biopsy. Within the group of clips that had displaced, the magnitude of displacement was compared. There was a significant difference in displacement among the clip types (P < .0001) with significant pairwise comparisons between pediatric surgical clips and SecureMark (38% vs 28%; P = .001) and SenoMark (38% vs 27%; P = .0001) in the proportion displaced. The surgical clips showed a significant magnitude of displacement of approximately 25% greater average distance displaced. As a whole, the commercial clips performed better than the surgical clip after stereotactic vacuum-assisted core biopsy suggesting the surrounding outer component acts to anchor the central clip and minimizes clip displacement. The same should apply to tomosynthesis-guided biopsy. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  16. Matrix Characterization and Development for the Vacuum Assisted Resin Transfer Molding Process

    NASA Technical Reports Server (NTRS)

    Grimsley, B. W.; Hubert, P.; Hou, T. H.; Cano, R. J.; Loos, A. C.; Pipes, R. B.

    2001-01-01

    The curing kinetics and viscosity of an epoxy resin system, SI-ZG-5A, have been characterized for application in the vacuum assisted resin transfer molding (VARTM) process. Impregnation of a typical carbon fiber perform provided the test bed for the characterization. Process simulations were carried out using the process model, COMPRO, to examine heat transfer and curing kinetics for a fully impregnated panel, neglecting resin flow. The predicted viscosity profile and final degree of cure were found to be in good agreement with experimental observations.

  17. Ultrasound-assisted extraction coupled with under vacuum distillation of flavour compounds from spearmint (carvone-rich) plants: Comparison with conventional hydrodistillation.

    PubMed

    Da Porto, Carla; Decorti, Deborha

    2009-08-01

    Ultrasonically assisted extraction of flavour compounds from different varieties of Mentha spicata, using 70% ethanol, have been carried out for 5, 10 and 15min and coupled with under vacuum distillation. The ultrasound distilled extracts have been analysed by GC-MS and compared with essential oils obtained by hydrodistillation. The results have showed that ultrasonically assisted extraction in combination with under vacuum distillation have provided extracts with higher flavouring strength due to the increased concentration of desirable oxygenated compounds (from 5 to 8 times) compared with hydrodistillation. Extraction yields of flavour volatiles have been calculated giving a range 0.04-0.13% by ultrasound and 0.01-0.02% by hydrodistillation.

  18. Techniques for assisting difficult delivery at caesarean section.

    PubMed

    Waterfall, Heather; Grivell, Rosalie M; Dodd, Jodie M

    2016-01-31

    Caesarean section involves making an incision in the woman's abdomen and cutting through the uterine muscle. The baby is then delivered through that incision. Difficult caesarean birth may result in injury for the infant or complications for the mother. Methods to assist with delivery include vacuum or forceps extraction or manual delivery utilising fundal pressure. Medication that relaxes the uterus (tocolytic medication) may facilitate the birth of the baby at caesarean section. Delivery of the impacted head after prolonged obstructed labour can be associated with significant maternal and neonatal complication; to facilitate delivery of the head the surgeon may utilise either reverse breech extraction or head pushing. To compare the use of tocolysis (routine or selective use) with no use of tocolysis or placebo and to compare different extraction methods at the time of caesarean section for outcomes of infant birth trauma, maternal complications (particularly postpartum haemorrhage requiring blood transfusion), and long-term measures of infant and childhood morbidity. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (30 September 2015) and reference lists of retrieved studies. All published, unpublished, and ongoing randomised controlled trials comparing the use of tocolytic agents (routine or selective) at caesarean section versus no use of tocolytic or placebo at caesarean section to facilitate the birth of the baby. Use of instrument versus manual delivery to facilitate birth of the baby. Reverse breech extraction versus head pushing to facilitate delivery of the deeply impacted fetal head. Two review authors independently assessed trials for inclusion and risk of bias, extracted data and checked them for accuracy. Seven randomised controlled trials, involving 582 women undergoing caesarean section were included in this review. The risk of bias of included trials was variable, with some trials not adequately describing allocation or

  19. Drying based on temperature-detection-assisted control in microwave-assisted pulse-spouted vacuum drying.

    PubMed

    Cao, Xiaohuang; Zhang, Min; Qian, He; Mujumdar, Arun S

    2017-06-01

    An online temperature-detection-assisted control system of microwave-assisted pulse-spouted vacuum drying was newly developed. By using this system, temperature control can be automatically and continuously adjusted based on the detection of drying temperature and preset temperature. Various strategies for constant temperature control, linear temperature control and three-step temperature control were applied to drying carrot cubes. Drying kinetics and the quality of various temperature-controlled strategies online are evaluated for the new drying technology as well as its suitability as an alternative drying method. Drying time in 70 °C mode 1 had the shortest drying time and lowest energy consumption in all modes. A suitable colour, highest re-hydration ratio and fracture-hardness, and longest drying time occurred in 30-40-50 °C mode 3. The number of hot spots was reduced in 40-50-60 °C mode 3. Acceptable carrot snacks were obtained in 50-60-70 °C mode 3 and 70 °C mode 2. All temperature curves showed that the actual temperatures followed the preset temperatures appropriately. With this system, a linear temperature-controlled strategy and a three-step temperature-controlled strategy can improve product quality and heating non-uniformity compared to constant temperature control, but need greater energy consumption and longer drying time. A temperature-detection-assisted control system was developed for providing various drying strategies as a suitable alternative in making a snack product. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  20. A Brief Introduction of Assistive Technology Service Delivery System in Republic of Korea.

    PubMed

    Lim, MyungJoon; Jung, SungMin

    2015-01-01

    Social participation of People with Disability in Republic of Korea has been grown last few years. Also demand of Assistive Technology has been increased as well. Responding these needs, the public benefits of Assistive Technology Device in Republic of Korea in 2014 was USD 1.7 billion which had been increased by 27 percent during the last five years. Despite an increase in the budget, effort to build Assistive Technology Service Delivery System (ATSDS) was not enough. Therefore, Ministry of Health and Welfare in Korea decided to build ATSDS in Republic of Korea in 2009. In this paper, the process of establishing ATSDS and 2014 outcomes of ATSDS are presented in details. For more than six years efforts of establishing national-wide ATSDS, nine Assistive Technology Centers were actively running in their delivery of service in 2014. As of 2014 outcomes of ATSDS, 14,056 cases were delivered through nine Assistive Technology Centers. The presence of ATSDS proved increase in accessibility for Assistive Technology for People with Disability followed by improvement of the quality of life of them.

  1. Traction force during vacuum extraction: a prospective observational study.

    PubMed

    Pettersson, K; Ajne, J; Yousaf, K; Sturm, D; Westgren, M; Ajne, G

    2015-12-01

    To investigate the traction force employed during vacuum extractions. Observational cross-sectional study. Obstetric Department, Karolinska University Hospital, Sweden, and the Swedish National Congress of Obstetrics and Gynaecology, 2013. Two hundred women with vacuum extraction at term and 130 obstetricians participating in a simulated setting. In a normal clinical setting, we used a specially adapted device to measure and record the force used to undertake vacuum extraction. In a subsequent part of the study, the force employed for vacuum extraction by a group of obstetricians in a fictive setting was estimated and objectively measured. Applied force during vacuum extraction in relation to the estimated level of difficulty in the delivery; perinatal diagnoses of asphyxia or head trauma; estimated force compared with objectively measured force employed in the fictive setting. The median (minimum-maximum) peak forces for minimum, average and excessive vacuum extraction in the clinical setting were 176 N (5-360 N), 225 N (115-436 N), and 241 N (164-452 N), respectively. In 34% of cases a force in excess of 216 N was employed. There was no correlation between the umbilical arterial pH at delivery and the traction force employed during extraction. Four cases of mild hypoxic ischaemic encephalopathy were observed, three of which were associated with a delivery whereby excessive traction force was employed during the vacuum extraction. In the fictive setting, the actual exerted force was twice the quantitative estimation. The measured forces in the clinical setting were four times higher than that estimated in the fictive setting. Higher than expected levels of traction force were used for vacuum extraction delivery. As obstetricians tend to underestimate the force applied during vacuum extraction, objective measurement with instantaneous feedback may be valuable in raising awareness. © 2015 Royal College of Obstetricians and Gynaecologists.

  2. Polyimide Composites Properties of RTM370 Fabricated by Vacuum Assisted Resins Transfer Molding (VARTM)

    NASA Technical Reports Server (NTRS)

    Chuang, Kathy C.; Criss, Jim M.; Mintz, Eric A.

    2011-01-01

    RTM370 imide resin based on 2,3,3 ,4 -biphenyl dianhydride ( a-BPDA), 3,4 -oxydianinline (3,4 -ODA) with 4-phenylethynylphthalic (PEPA) endcap has shown to exhibit high Tg (370 C) and low melt viscosity (10-30 poise) at 280 C with a pot-life of 1-2 h. Previously, RTM370 resin has been fabricated into composites with T650-35 carbon fabrics by resin transfer molding (RTM) successfully. RTM370 composites exhibit excellent mechanical properties up to 327 C (620 F), and outstanding property retention after aging at 288 C (550 F) for 1000 hrs. In this presentation, RTM 370 composites will be fabricated by vacuum assisted resins transfer molding (VARTM), using vacuum bags without mold. The mechanical properties of RTM370 composites fabricated by VARTM will be compared to those of RTM370 made by RTM.

  3. Flow and Compaction During the Vacuum Assisted Resin Transfer Molding Process

    NASA Technical Reports Server (NTRS)

    Grimsley, Brian W.; Hubert, Pascal; Song, Xiao-Lan; Cano, Roberto J.; Loos, Alfred C.; Pipes, R. Byron

    2001-01-01

    The flow of an epoxy resin and compaction behavior of carbon fiber preform during vacuum- assisted resin transfer molding (VARTM) infiltration was measured using an instrumented tool. Composite panels were fabricated by the VARTM process using SAERTEX(R)2 multi-axial non- crimp carbon fiber fabric and the A.T.A.R.D. SI-ZG-5A epoxy resin. Resin pressure and preform thickness variation was measured during infiltration. The effects of the resin on the compaction behavior of the preform were measured. The local preform compaction during the infiltration is a combination of wetting and spring-back deformations. Flow front position computed by the 3DINFIL model was compared with the experimental data.

  4. Composite Properties of RTM370 Polyimide Fabricated by Vacuum Assisted Resin Transfer Molding (VARTM)

    NASA Technical Reports Server (NTRS)

    Chuang, Kathy C.; Criss, James M.; Mintz, Eric A.; Shonkwiler, Brian; McCorkle, Linda S.

    2011-01-01

    RTM370 imide resin based on 2,3,3?,4?-biphenyl dianhydride (a-BPDA), 3,4'-oxydianinline (3,4'-ODA) with the 4-phenylethynylphthalic (PEPA) endcap has been shown to exhibit a high cured T(sub g) (370 C) and low melt viscosity (10-30 poise) at 280 C with a pot-life of 1-2 h. Previously, RTM370 resin has been successfully fabricated into composites reinforced with T650-35 carbon fabrics by resin transfer molding (RTM). RTM370 composites exhibit excellent mechanical properties up to 327?C (620?F), and outstanding property retention after aging at 288?C (550?F) for 1000 h. In this work, RTM370 composites were fabricated by vacuum assisted resin transfer molding (VARTM), using vacuum bags on a steel plate. The mechanical properties of RTM370 composites fabricated by VARTM are compared to those prepared by RTM.

  5. A Review of Research Methods Used to Examine Employee Assistance Program Delivery Options.

    ERIC Educational Resources Information Center

    Csiernik, Rick

    1995-01-01

    This review of literature on Employee Assistance Programs (EAPs) focuses on EAP delivery options. More than half of the 48 studies reviewed used a case study approach. EAPs provided by on-staff professionals were the most frequently discussed delivery option, although this is not the most dominant form of EAP provision. (SLD)

  6. Study on laser-assisted drug delivery with optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Tsai, Wen-Guei; Tsai, Ting-Yen; Yang, Chih-Hsun; Tsai, Meng-Tsan

    2017-04-01

    The nail provides a functional protection to the fingertips and surrounding tissue from external injuries. Nail plate divided into three layers including dorsal, intermediate, and ventral layers. The dorsal layer consists of compact, hard keratins, limiting topical drug delivery through the nail. In this study, we investigate the application of fractional CO2 laser that produces arrays of microthermal ablation zones (MAZs) to facilitate drug delivery in the nails. Moreover, optical coherence tomography (OCT) is implemented for real-time monitoring of the laser-skin tissue interaction, sparing the patient from invasive surgical sampling procedure. Observations of drug diffusion through the induced MAZ array are achieved by evaluating the time-dependent OCT intensity variance. Subsequently, nails are treated with cream and liquid topical drugs to investigate the feasibility and diffusion efficacy of laser-assisted drug delivery. Our results show that fractional CO2 laser improves the efficacy of topical drug delivery in the nail plate, and that OCT could potentially be used for in vivo monitoring of the depth of laser penetration as well as real-time observations of drug delivery.

  7. Homogenate-assisted Vacuum-powered Bubble Extraction of Moso Bamboo Flavonoids for On-line Scavenging Free Radical Capacity Analysis.

    PubMed

    Sun, Yinnan; Yang, Kui; Cao, Qin; Sun, Jinde; Xia, Yu; Wang, Yinhang; Li, Wei; Ma, Chunhui; Liu, Shouxin

    2017-07-11

    A homogenate-assisted vacuum-powered bubble extraction (HVBE) method using ethanol was applied for extraction of flavonoids from Phyllostachys pubescens (P. pubescens) leaves. The mechanisms of homogenate-assisted extraction and vacuum-powered bubble generation were discussed in detail. Furthermore, a method for the rapid determination of flavonoids by HPLC was established. HVBE followed by HPLC was successfully applied for the extraction and quantification of four flavonoids in P. pubescens , including orientin, isoorientin, vitexin, and isovitexin. This method provides a fast and effective means for the preparation and determination of plant active components. Moreover, the on-line antioxidant capacity, including scavenging positive ion and negative ion free radical capacity of different fractions from the bamboo flavonoid extract was evaluated. Results showed that the scavenging DPPH ˙ free radical capacity of vitexin and isovitexin was larger than that of isoorientin and orientin. On the contrary, the scavenging ABTS⁺ ˙ free radical capacity of isoorientin and orientin was larger than that of vitexin and isovitexin.

  8. Resection of giant right atrial lymphoma using vacuum-assisted cardiopulmonary bypass without snaring the inferior vena cava.

    PubMed

    Shin, Hankei; Mori, Mitsuharu; Matayoshi, Toru; Suzuki, Ryo; Yozu, Ryohei

    2004-08-01

    A 53-year-old man sustained hemodynamic collapse due to a huge right atrial tumor and was transferred to our hospital and underwent a life-saving emergency operation. The tumor arose from the inferolateral wall of the right atrium, occupying almost the whole right atrial cavity and obstructing not only the inflow of the right ventricle but also the orifice of the inferior vena cava. Venous cannulation via the right atrial wall and placing a snare around the inferior vena cava were impossible. With a cardiopulmonary bypass using vacuum-assisted venous drainage, the tumor was successfully resected and the tricuspid valve was replaced with a bioprosthetic valve without snaring the inferior vena cava. Postoperative histological examination demonstrated the tumor to be a large B-cell non-Hodgkin type malignant lymphoma. When the tumor is large and it is difficult to establish total cardiopulmonary bypass, the vacuum-assisted cardiopulmonary bypass is a useful option. This can achieve a bloodless operative field and is not blocked by the incoming air, due to the venous drainage being continually pressure-regulated.

  9. Mathematics Achievement: Traditional Instruction and Technology-Assisted Course Delivery Methods

    ERIC Educational Resources Information Center

    Vilardi, Robert; Rice, Margaret L.

    2014-01-01

    The purpose of this study was to analyze technology-assisted course delivery methods to determine their overall effectiveness as it pertains to mathematics courses. This study analyzed both current and historical data in the areas of achievement, retention, and grade distribution for mathematics classes. The study included 14,562 students enrolled…

  10. Mathematics Achievement: Traditional Instruction and Technology-Assisted Course Delivery Methods

    ERIC Educational Resources Information Center

    Vilardi, Robert

    2013-01-01

    The purpose of this study was to analyze technology-assisted course delivery methods to determine their overall effectiveness as it pertains to mathematics courses. This study analyzed both current and historical data in mathematics classes in the areas of achievement, retention, and grade distribution. The goal of this study was to determine if…

  11. Assessing West Virginia NIPF owner preferred forest management assistance topics and delivery methods

    Treesearch

    Daniel J. Magill; Rory F. Fraser; David W. McGill

    2003-01-01

    Four hundred and fourteen non-industrial private forest (NIPF) owners in West Virginia responded to a mail survey questionnaire assessing their forest management assistance topics and delivery methods of interest. Logistic regression was used to analyze 39 independent variables in relation to the dependent variables of wanting a specific topic of forestry assistance or...

  12. Perinatal and maternal morbidity and mortality after attempted operative vaginal delivery at midpelvic station

    PubMed Central

    Muraca, Giulia M.; Sabr, Yasser; Lisonkova, Sarka; Skoll, Amanda; Brant, Rollin; Cundiff, Geoffrey W.; Joseph, K.S.

    2017-01-01

    BACKGROUND: Increased use of operative vaginal delivery (i.e., forceps or vacuum application), of which 20% occurs at midpelvic station, has been advocated to reduce the rate of cesarean delivery. We aimed to quantify severe perinatal and maternal morbidity and mortality associated with attempted midpelvic operative vaginal delivery. METHODS: We studied all term singleton deliveries in Canada between 2003 and 2013, by attempted midpelvic operative vaginal or cesarean delivery with labour (with and without prolonged second stage). The primary outcomes were composite severe perinatal morbidity and mortality (e.g., convulsions, assisted ventilation, severe birth trauma and perinatal death), and composite severe maternal morbidity and mortality (e.g., severe postpartum hemorrhage, shock, sepsis, cardiac complications, acute renal failure and death). RESULTS: The study population included 187 234 deliveries. Among women with dystocia and prolonged second stage of labour, midpelvic operative vaginal delivery was associated with higher rates of severe perinatal morbidity and mortality compared with cesarean delivery (forceps, adjusted odds ratio [AOR] 1.81, 95% confidence interval [CI] 1.24 to 2.64; vacuum, AOR 1.81, 95% CI 1.17 to 2.80; sequential instruments, AOR 3.19, 95% CI 1.73 to 5.88), especially with higher rates of severe birth trauma. Rates of severe maternal morbidity and mortality were not significantly different after operative vaginal delivery, although rates of obstetric trauma were higher (forceps, AOR 4.51, 95% CI 4.04 to 5.02; vacuum, AOR 2.70, 95% CI 2.35 to 3.09; sequential instruments, AOR 4.24, 95% CI 3.46 to 5.19). Among women with fetal distress, similar associations were seen for severe birth trauma and obstetric trauma, although vacuum was associated with lower rates of severe maternal morbidity and mortality (AOR 0.52, 95% CI 0.33 to 0.80). Associations tended to be stronger among women without a prolonged second stage. INTERPRETATION: Midpelvic

  13. An effective vacuum assisted extraction method for the optimization of labdane diterpenoids from Andrographis paniculata by response surface methodology.

    PubMed

    Wang, Ya-Qi; Wu, Zhen-Feng; Ke, Gang; Yang, Ming

    2014-12-31

    An effective vacuum assisted extraction (VAE) technique was proposed for the first time and applied to extract bioactive components from Andrographis paniculata. The process was carefully optimized by response surface methodology (RSM). Under the optimized experimental conditions, the best results were obtained using a boiling temperature of 65 °C, 50% ethanol concentration, 16 min of extraction time, one extraction cycles and a 12:1 liquid-solid ratio. Compared with conventional ultrasonic assisted extraction and heat reflux extraction, the VAE technique gave shorter extraction times and remarkable higher extraction efficiency, which indicated that a certain degree of vacuum gave the solvent a better penetration of the solvent into the pores and between the matrix particles, and enhanced the process of mass transfer. The present results demonstrated that VAE is an efficient, simple and fast method for extracting bioactive components from A. paniculata, which shows great potential for becoming an alternative technique for industrial scale-up applications.

  14. Site and incidence of birth canal lacerations from instrumental delivery with mediolateral episiotomy.

    PubMed

    Chikazawa, Kenro; Ushijima, Junko; Takagi, Kenjiro; Nakamura, Eishin; Samejima, Koki; Kadowaki, Kanako; Horiuchi, Isao

    2016-12-01

    Instrument-assisted vaginal delivery is a significant risk factor for birth canal lacerations. Although many obstetricians recently are recommending restrictive rather than a routine episiotomy, reports have shown restrictive episiotomy to be associated with more extensive anterior birth canal trauma compared with routine episiotomy. We retrospectively reviewed 110 cases of forceps and vacuum deliveries and investigated the site of birth canal lacerations. Birth canal lacerations were divided into four sites according to direction-anterior, ipsilateral, contralateral, and posterior. The frequency of lacerations were, from most to least, posterior (34%), lateral (21.7%), and anterior (1.9%). Moreover, among the lateral lacerations, they were more frequent in the contralateral side of episiotomy than the ipsilateral side (18.9% vs. 4.7%, p < 0.01). Our results indicate that caution is also needed concerning not only the anterior site, but also the contralateral site of an episiotomy to prevent laceration in an instrument-assisted vaginal delivery. Copyright © 2016. Published by Elsevier B.V.

  15. Laser-assisted delivery of topical methotrexate - in vitro investigations.

    PubMed

    Taudorf, Elisabeth Hjardem

    2016-06-01

    Ablative fractional lasers (AFXL) are increasingly used to treat dermatological disorders and to facilitate laser-assisted topical drug delivery. In this thesis, laser-tissue interactions generated by stacked pulses with a miniaturized low-power 2,940 nm AFXL were characterized (study I). Knowledge of the correlation between laser parameters and tissue effects was used to deliver methotrexate (MTX) topically through microscopic ablation zones (MAZs) of precise dimensions. MTX is a well-known chemotherapeutic and anti-inflammatory drug that may cause systemic adverse effects, and topical delivery is thus of potential benefit. The impact of MAZ depth (study II) and transport kinetics (study III) on MTX deposition in skin as well as transdermal permeation was determined in vitro. Quantitative analyses of dermal and transdermal MTX concentrations were performed by high performance liquid chromatography (HPLC) (study II & III), while qualitative analyses of MTX biodistribution in skin were illustrated and semi-quantified by fluorescence microscopy (study II & III) and desorption electro spray mass spectrometry imaging (DESI-MSI) (study III). Laser-tissue interactions generated by AFXL: AFXL-exposure generated a variety of MAZ-dimensions. MAZ depth increased linearly with the logarithm of total energy delivered by stacked pulses, but was also affected by variations in power, pulse energy, pulse duration, and pulse repetition rate. Coagulation zones lining MAZs increased linearly with the applied total energy, while MAZ width increased linearly with the logarithm of stacked pulses. Results were gathered in a mathematical model estimating relations between laser parameters and specific MAZ dimensions. Impact of MAZ depth on AFXL-assisted topical MTX delivery: Pretreatment by AFXL facilitated topical MTX delivery to all skin layers. Deeper MAZs increased total MTX deposition in skin compared to superficial MAZs and altered the intradermal biodistribution profile towards

  16. Socio-economic factors associated with delivery assisted by traditional birth attendants in Iraq, 2000.

    PubMed

    Siziya, Seter; Muula, Adamson S; Rudatsikira, Emmanuel

    2009-04-02

    Traditional birth attendants (TBAs) are likely to deliver lower quality maternity care compared to professional health workers. It is important to characterize women who are assisted by TBAs in order to design interventions specific to such groups. We thus conducted a study to assess if socio-economic status and demographic factors are associated with having childbirth supervised by traditional birth attendants in Iraq. Iraqi Multiple Indicator Cluster Survey (MICS) data for 2000 were used. We estimated frequencies and proportions of having been delivered by a traditional birth attendant and other social characteristics. Logistic regression analysis was used to assess the association between having been delivered by a TBA and wealth, area of residence (urban versus rural), parity, maternal education and age. Altogether 22,980 women participated in the survey, and of these women, 2873 had delivery information and whether they were assisted by traditional birth attendants (TBAs) or not during delivery. About 1 in 5 women (26.9%) had been assisted by TBAs. Compared to women of age 35 years or more, women of age 25-34 years were 22% (AOR = 1.22, 95%CI [1.08, 1.39]) more likely to be assisted by TBAs during delivery. Women who had no formal education were 42% (AOR = 1.42, 95%CI [1.22, 1.65]) more likely to be delivered by TBAs compared to those who had attained secondary or higher level of education. Women in the poorest wealth quintile were 2.52 (AOR = 2.52, 95%CI [2.14, 2.98]) more likely to be delivered by TBAs compared to those in the richest quintile. Compared to women who had 7 or more children, those who had 1 or 2 were 28% (AOR = 0.72, 95%CI [0.59, 0.87]) less likely to be delivered by TBAs. Findings from this study indicate that having delivery supervised by traditional birth attendants was associated with young maternal age, low education, and being poor. Meanwhile women having 1 or 2 children were less likely to be delivered by TBAs. These factors should be

  17. Laser-assisted delivery of synergistic combination chemotherapy in in vivo skin.

    PubMed

    Wenande, Emily; Tam, Joshua; Bhayana, Brijesh; Schlosser, Steven Kyle; Ishak, Emily; Farinelli, William A; Chlopik, Agata; Hoang, Mai P; Pinkhasov, Omar R; Caravan, Peter; Rox Anderson, R; Haedersdal, Merete

    2018-04-10

    The effectiveness of topical drugs for treatment of non-melanoma skin cancer is greatly reduced by insufficient penetration to deep skin layers. Ablative fractional lasers (AFLs) are known to enhance topical drug uptake by generating narrow microchannels through the skin, but information on AFL-drug delivery in in vivo conditions is limited. In this study, we examined pharmacokinetics, biodistribution and toxicity of two synergistic chemotherapy agents, cisplatin and 5-fluorouracil (5-FU), following AFL-assisted delivery alone or in combination in in vivo porcine skin. Detected at 0-120 h using mass spectrometry techniques, we demonstrated that fractional CO 2 laser pretreatment (196 microchannels/cm 2 , 852 μm ablation depth) leads to rapid drug uptake in 1500 μm deep skin layers, with a sixfold enhancement in peak cisplatin concentrations versus non-laser-treated controls (5 h, P = 0.005). Similarly, maximum 5-FU deposition was measured within an hour of AFL-delivery, and exceeded peak deposition in non-laser-exposed skin that had undergone topical drug exposure for 5 days. Overall, this accelerated and deeper cutaneous drug uptake resulted in significantly increased inflammatory and histopathological effects. Based on clinical scores and transepidermal water loss measurement, AFL intensified local toxic responses to drugs delivered alone and in combination, while systemic drug exposure remained undetectable. Quantitative histopathologic analyses correspondingly revealed significantly reduced epidermal proliferation and greater cellular apoptosis after AFL-drug delivery; particularly after combined cisplatin + 5-FU exposure. In sum, by overcoming the primary limitation of topical drug penetration and providing accelerated, enhanced and deeper delivery, AFL-assisted combination chemotherapy may represent a promising treatment strategy for non-melanoma skin cancer. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Fetal macrosomia as a risk factor for shoulder dystocia during vacuum extraction.

    PubMed

    Herzberg, Shmuel; Kabiri, Doron; Mordechai, Tzlil; Haj Yahya, Rani; Chill, Henry; Levitt, Lorinne; Amsalem, Hagai; Ezra, Yossef

    2017-08-01

    Vacuum extraction of a macrosomic fetus is considered a risk factor for shoulder dystocia (SD). We evaluated maternal and fetal outcomes following vacuum extraction of macrosomic infants. A retrospective cohort study conducted in two large teaching hospitals. All deliveries of macrosomic infants by vacuum extraction and vaginal delivery were compared. The primary outcome measure was SD. Secondary outcome measures were severe perineal lacerations and postpartum hemorrhage. For statistical analysis, we used McNemar's test and χ 2 or Fisher's exact tests. Odds ratios were analyzed via a logistic regression model. From 2003 to 2013, there were 6019 (5.45%) deliveries of macrosomic fetuses, and 230 (0.21%) were delivered by vacuum extraction. There were 23 (10%) and seven (3.04%) cases of SD in the study and control groups, respectively. The risk of SD was significantly higher in the study group (p > 0.05). We found a significant association between SD and vacuum delivery [p = 0.003; OR = 3.54 (95% CI: 1.49-8.42)]. The composite adverse neonatal outcome rate was 6.5% (15/230) and 1.7% (4/230) in the study and control groups, respectively (p = 0.009). Vacuum extraction of a macrosomic infant is a risk factor for shoulder dystocia but not for postpartum hemorrhage or severe vaginal tears.

  19. Integrated Cooling-Vacuum-Assisted Non-Fractional 1540 nm Erbium:Glass Laser is Effective in Treating Acne Scars.

    PubMed

    Politi, Yael; Levi, Assi; Lapidoth, Moshe

    2016-11-01

    Acne scars are a common result of in ammatory acne, affecting many patients worldwide. Among which, atrophic scars are the most prevalent form, presenting as dermal depressions caused by inflammatory degeneration of dermal collagen. Mid-infrared laser skin interaction is characterized by its modest absorption in water and nite penetration to the mid-dermis. Since collagen is a desirable laser target, 1540-nm wavelength is amenable for collagen remodeling within the depressed area of atrophic scars. To evaluate the safety and efficacy of acne scars treatment using an integrated cooling-vacuum-assisted 1540 nm Erbium: Glass Laser. This interventional prospective study included 25 volunteers (10 men, 15 women) with post acne atrophic scars. Patients were treated with a mid-infrared non-fractional 1540 nm Er:Glass laser (Alma Lasers Ltd. Caesarea, Israel) with integrat- ed cooling- vacuum assisted technology. Acne scars were exposed to 3 stacked laser pulses (400-600 mJ/pulse, 4 mm spot size, frequency of 3 Hz). Patients underwent 3-6 treatment sessions with a 2-3 week interval and were followed-up 1 month and 3 months after the last treatment. Clinical photographs were taken by high resolution digital camera before and after treatment. Clinical evaluation was performed by two independent dermatologists and results were graded on a scale of 0 (exacerbation) to 4 (76%-100% improvement). Patients' and physicians' satisfaction were also recorded (on a 1-5 scale). Pain perception and adverse effects were evaluated as well. Almost all patients (24/25) demonstrated a moderate to significant improvement. Average improvement was 3.9 and 4.1 points on the quartile scale used for outcome assessment 1 and 3 months following the last session, respectively. Patient satisfaction rate was 4.2. Side effects were minimal and transient: erythema, mild transient vesicles, and mild pain or inconvenience. CONCLUSION Cooling-Vacuum-Assisted mid-infrared non-fractional Er:Glass 1540 nm laser

  20. Histology after lumpectomy in women with epithelial atypia on stereotactic vacuum-assisted breast biopsy.

    PubMed

    Graesslin, O; Antoine, M; Chopier, J; Seror, J Y; Flahault, A; Callard, P; Daraï, E; Uzan, S

    2010-02-01

    Large-core needle biopsy of the breast (LCNB) and vacuum-assisted breast biopsy (VABB) are widely used as alternatives to open surgical biopsy (OSB) for initial diagnosis of mammographic abnormalities. Between 18% and 80% of cases in which such specimens show atypical lobular hyperplasia (ALH) or atypical ductal hyperplasia (ADH) are found to be malignant at surgery. From 1999 to 2005, 68 women with mammographic abnormalities were sampled by stereotactic VABB and presented atypical epithelial hyperplasia. Immunohistochemical staining with anti-cytokeratin 5/6 and anti-E-cadherin antibodies was performed. All women underwent a lumpectomy. Clinical, radiological or histological factors predictive of the risk of finding malignancy at surgery were sought. VABB initially showed 28 cases of ADH, 32 cases of ALH, one case of flat epithelial atypia, five cases of mixed atypia, and two cases of Lobular Carcinoma In Situ (LCIS). After slide review with immunohistochemical staining, two cases of ADH were reclassified as simple hyperplasia and two cases of ALH were reclassified as mixed atypia. Seven lesions (10.3%) that appeared to be benign on VABB were found to be malignant on OSB (Ductal Carcinoma In Situ (DCIS) in six cases and invasive ductal carcinoma in one case). ADH was the only predictive factor of malignancy on OSB (p=0.04 versus ALH). ADH diagnosed by vacuum-assisted breast biopsy frequently corresponds to cancer on open surgical biopsy. Surgical excision of all breast lesions containing atypical hyperplasia on percutaneous biopsy can be recommended. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  1. Magnet Assisted Composite Manufacturing: A Flexible New Technique for Achieving High Consolidation Pressure in Vacuum Bag/Lay-Up Processes.

    PubMed

    Pishvar, Maya; Amirkhosravi, Mehrad; Altan, M Cengiz

    2018-05-17

    This work demonstrates a protocol to improve the quality of composite laminates fabricated by wet lay-up vacuum bag processes using the recently developed magnet assisted composite manufacturing (MACM) technique. In this technique, permanent magnets are utilized to apply a sufficiently high consolidation pressure during the curing stage. To enhance the intensity of the magnetic field, and thus, to increase the magnetic compaction pressure, the magnets are placed on a magnetic top plate. First, the entire procedure of preparing the composite lay-up on a magnetic bottom steel plate using the conventional wet lay-up vacuum bag process is described. Second, placement of a set of Neodymium-Iron-Boron permanent magnets, arranged in alternating polarity, on the vacuum bag is illustrated. Next, the experimental procedures to measure the magnetic compaction pressure and volume fractions of the composite constituents are presented. Finally, methods used to characterize microstructure and mechanical properties of composite laminates are discussed in detail. The results prove the effectiveness of the MACM method in improving the quality of wet lay-up vacuum bag laminates. This method does not require large capital investment for tooling or equipment and can also be used to consolidate geometrically complex composite parts by placing the magnets on a matching top mold positioned on the vacuum bag.

  2. An inflatable ergonomic 3-chamber fundal pressure belt to assist vaginal delivery.

    PubMed

    Acanfora, Luisa; Rampon, Michela; Filippeschi, Marco; Marchi, Marco; Montisci, Massimo; Viel, Guido; Cosmi, Erich

    2013-01-01

    To evaluate whether Baby-guard-a new medical device with an ergonomic 3-chamber inflatable abdominal belt-can reduce complications associated with vaginal delivery. A randomized controlled single-blind prospective study of 80 pregnant women delivering at term was conducted at San Giuseppe Hospital, Empoli, Italy. In the study group (n=40), the abdominal belt was inflated to optimal therapeutic pressures. In the control group (n=40), the abdominal belt was inflated to minimal, non-therapeutic pressures. Factors relating to maternal, fetal, and labor complications during vaginal delivery were evaluated. Compared with the control group, women in the study group experienced a lower incidence of perineal and cervical lacerations (P<0.001); reduced use of the Kristeller maneuver (P<0.001); shorter duration of the second stage of labor (P<0.001); less psychologic and physical fatigue (P<0.001); fewer maternal requests for cesarean delivery during labor (P<0.001); fewer vacuum extractions (P<0.01); and fewer cesarean deliveries (P<0.02). No neonatal intensive care unit admissions were recorded in the study group versus 7 in the control group (P<0.012). Use of the ergonomic 3-chamber inflatable abdominal belt system reduced the incidence of risks associated with vaginal labor. Clinical trials.gov identifier: NCT01566331. Copyright © 2012 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  3. Can Vacuum Assisted Venous Drainage be Achieved using a Roller Pump in an Emergency? A Pilot Study using Neonatal Circuitry

    PubMed Central

    Hill, S. L.; Holt, D. W.

    2007-01-01

    Abstract: There has been much advancement in perfusion technology over its 50 years of progression. One of these techniques is vacuum-assisted venous drainage (VAVD). Many perfusionists augment venous drainage using VAVD, typically from a wall vacuum source. This study explores alternates to providing VAVD if the wall vacuum fails. In two porcine laboratories, ∼36 in. of 3/16-in. tubing was connected to a sucker return port and placed into the roller head next to the arterial pump. The vacuum was monitored with a DLP pressure monitoring system (Medtronic). This system was connected to small-bore tubing and attached to a stopcock on top of the reservoir. The vacuum was regulated using another stopcock connected to a non-filtered luer lock port on top of the reservoir or by a segment of 3 × 0.25-in.-diameter tubing attached to the vent port with a c-clamp. Vacuum drainage was achieved, ranging from −18 mmHg to −71 mmHg by manipulating the stopcock or c-clamp. Changes in venous drainage were seen by volume fluctuations in the venous reservoir. The vacuum was adjusted to account for dramatic changes. Augmented venous drainage using a roller pump can be achieved successfully during cardiopulmonary bypass (CPB). This method of active drainage can be used in lieu of wall suction or during times of emergency if wall suction fails. PMID:18293812

  4. Pilot study of a novel vacuum-assisted method for decellularization of tracheae for clinical tissue engineering applications.

    PubMed

    Lange, P; Greco, K; Partington, L; Carvalho, C; Oliani, S; Birchall, M A; Sibbons, P D; Lowdell, M W; Ansari, T

    2017-03-01

    Tissue engineered tracheae have been successfully implanted to treat a small number of patients on compassionate grounds. The treatment has not become mainstream due to the time taken to produce the scaffold and the resultant financial costs. We have developed a method for decellularization (DC) based on vacuum technology, which when combined with an enzyme/detergent protocol significantly reduces the time required to create clinically suitable scaffolds. We have applied this technology to prepare porcine tracheal scaffolds and compared the results to scaffolds produced under normal atmospheric pressures. The principal outcome measures were the reduction in time (9 days to prepare the scaffold) followed by a reduction in residual DNA levels (DC no-vac: 137.8±48.82 ng/mg vs. DC vac 36.83±18.45 ng/mg, p<0.05.). Our approach did not impact on the collagen or glycosaminoglycan content or on the biomechanical properties of the scaffolds. We applied the vacuum technology to human tracheae, which, when implanted in vivo showed no significant adverse immunological response. The addition of a vacuum to a conventional decellularization protocol significantly reduces production time, whilst providing a suitable scaffold. This increases clinical utility and lowers production costs. To our knowledge this is the first time that vacuum assisted decellularization has been explored. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  5. Employee assistance programs: an alternative resource for mental health service delivery.

    PubMed

    Santa-Barbara, J

    1984-09-01

    The purpose of this article is to provide a very brief introduction to employee assistance programs (EAPs) and their role in the mental health delivery system. In addition, some consideration will be given to the opportunity these programs offer for making a significant impact on both the mental health of Canadians and the productivity of Canadian business.

  6. Abdominal Subcutaneous Mass After Laser-Assisted Lipolysis and Immediate Multiple Treatments with a Dual-Wavelength Laser, Vacuum and Massage Device.

    PubMed

    Gentileschi, Stefano; Servillo, Maria; D'Ettorre, Marco; Salgarello, Marzia

    2016-04-01

    Body contouring by means of minimally invasive procedures is a growing trend. Current approaches to body contouring often involve a combination of surgical techniques (eg, laser-assisted liposuction) and a series of noninvasive device-based treatments aimed at accelerating recovery and improving aesthetic outcomes. In this case study, we describe a 38-year-old woman who presented with an abdominal-wall mass that resembled a tumor when assessed with magnetic resonance imaging. Twenty-six months before presenting to our office, the patient had undergone laser lipolysis and a series of treatments with a device that delivered dual-wavelength laser energy and vacuum-assisted massage. To address the patient's concerns, we removed the mass and performed abdominal dermolipectomy. No postoperative complications occurred, and the patient was highly satisfied with the aesthetic outcome. The results of histologic studies indicated that the mass was pseudocystic and fluid-filled, surrounded by a fibrous capsule, and characterized as a foreign-body granuloma. Further analysis is warranted regarding the safety of laser lipolysis without aspiration combined with a device delivering dual-wavelength laser energy and vacuum-assisted massage. 5 Risk. © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  7. User involvement in service delivery predicts outcomes of assistive technology use: a cross-sectional study in Bangladesh.

    PubMed

    Borg, Johan; Larsson, Stig; Ostergren, Per-Olof; Rahman, A S M Atiqur; Bari, Nazmul; Khan, A H M Noman

    2012-09-20

    Knowledge about the relation between user involvement in the provision of assistive technology and outcomes of assistive technology use is a prerequisite for the development of efficient service delivery strategies. However, current knowledge is limited, particularly from low-income countries where affordability is an issue. The objective was therefore to explore the relation between outcomes of assistive technology use and user involvement in the service delivery process in Bangladesh. Using structured interviews, data from 136 users of hearing aids and 149 users of manual wheelchairs were collected. Outcomes were measured using the International Outcome Inventory for Hearing Aids (IOI-HA), which was adapted for wheelchair users. Predictors of user involvement included preference, measurement and training. Users reported outcomes comparable to those found in other high- and low-income countries. User involvement increased the likelihood for reporting better outcomes except for measurement among hearing aid users. The findings support the provision of assistive technology as a strategy to improve the participation of people with disabilities in society. They also support current policies and guidelines for user-involvement in the service delivery process. Simplified strategies for provision of hearing aids may be explored.

  8. Early Conversion of External Fixation to Interlocked Nailing in Open Fractures of Both Bone Leg Assisted with Vacuum Closure (VAC) - Final Outcome

    PubMed Central

    Raj, Manish; Kumar, Sunil; Singh, Pulkesh; Kumar, Dinesh; Singh, Jasveer; Deep, Akash

    2016-01-01

    Introduction Management of compound grade III fractures of both bone leg includes external stabilization for long period, followed by various soft tissue coverage procedures. Primary interlocking of tibia had been also done with variable results. External fixation for long time without any bone loss often leads to infected nonunion, loss of reduction, pin tract infection and failure of fixation, primary interlocking in compound grade III fractures had shown high medullary infection rate. We managed all cases of compound grade III A/B fractures with primary external fixation, simultaneous wound management using vacuum assisted closure (VAC) followed by early conversion to interlocking within 2 weeks of fixator application. Aim To determine the effectiveness of vacuum assisted closure (VAC) for the early conversion of external fixator to definitive interlocking in open fractures of the both bone leg. Materials and Methods In current study we selected 84 cases of compound grade IIIA/B diaphyseal fractures of both bone leg during period of May 2010 to September 2013. We managed these cases by immediate debridement and application of external fixation followed by repeated debridement, application of vacuum assisted closure (VAC) and conversion to interlocking within two weeks. Results Out of 84 cases union was achieved in 80(95%) of cases with definitive tibial interlocking. Excellent to good result were obtained in 77(91.8%) of cases and fair to poor result seen in rest of 7(8.2%) of cases according to modified Ketenjian’s criteria. 5 out of these 7 poor result group cases were from Compound Grade III B group to start with. Deep infection rate in our series were 7% i.e. total 6 cases and 4 out of these were from compound Grade III B group to start with. Conclusion Vacuum assisted closure (VAC) give a good help for rapid closure of the wound and help in early conversion to definitive intramedullary nailing. Reamed nail could well be used in compound grade IIIA

  9. Technical specification for vacuum systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khaw, J.

    The vacuum systems at the Stanford Linear Accelerator Center (SLAC) are primarily of all-metal construction and operate at pressures from 10/sup -5/ to 10/sup -11/ Torr. The primary gas loads during operation result from thermal desorption and beam-induced desorption from the vacuum chamber walls. These desorption rates can be extremely high in the case of hydrocarbons and other contaminants. These specifications place a major emphasis on eliminating contamination sources. The specifications and procedures have been written to insure the cleanliness and vacuum integrity of all SLAC vacuum systems, and to assist personnel involved with SLAC vacuum systems in choosing andmore » designing components that are compatible with existing systems and meet the quality and reliability of SLAC vacuum standards. The specification includes requirements on design, procurement, fabrication, chemical cleaning, clean room practices, welding and brazing, helium leak testing, residual gas analyzer testing, bakeout, venting, and pumpdown. Also appended are specifications regarding acceptable vendors, isopropyl alcohol, bakeable valve cleaning procedure, mechanical engineering safety inspection, notes on synchrotron radiation, and specifications of numerous individual components. (LEW)« less

  10. Maternal and neonatal morbidity in relation to the instrument used for mid-cavity rotational operative vaginal delivery: a prospective cohort study.

    PubMed

    Bahl, R; Van de Venne, M; Macleod, M; Strachan, B; Murphy, D J

    2013-11-01

    To compare the maternal and neonatal morbidity associated with alternative instruments used to perform a mid-cavity rotational delivery. A prospective cohort study. Two university teaching hospitals in Scotland and England. Three hundred and eighty-one nulliparous women who had a mid-cavity rotational operative vaginal delivery. A data collection sheet was completed by the research team following delivery. Postpartum haemorrhage, third- and fourth-degree perineal tears, low cord pH, neonatal trauma, and failed or sequential operative vaginal delivery. One hundred and sixty-three women (42.8%) underwent manual rotation followed by non-rotational forceps delivery, 73 (19.1%) had a rotational vacuum delivery, and 145 (38.1%) delivered with the assistance of rotational (Kielland) forceps. The rates of postpartum haemorrhage were similar when comparing manual rotation with rotational vacuum (adjusted OR 1.42, 95% CI 0.66-3.98), and when comparing manual rotation with Kielland forceps (adjusted OR 1.22, 95% CI 0.71-2.88). The results were comparable for third- and fourth-degree perineal tears (adjusted OR 0.85, 95% CI 0.13-1.89; adjusted OR 0.94, 95% CI 0.39-1.82), low cord pH (adjusted OR 1.76, 95% CI 0.44-6.91; adjusted OR 1.12, 95% CI 0.44-2.83), neonatal trauma (adjusted OR 0.50, 95% CI 0.16-1.55; adjusted OR 3.25, 95% CI 0.65-16.17), and admission to the neonatal intensive care unit (adjusted OR 1.47, 95% CI 0.45-4.81; adjusted OR 1.04, 95% CI 0.49-2.19). The sequential use of instruments was less likely with manual rotation and forceps than with rotational vacuum delivery (0.6 versus 36.9%, OR 0.01, 95% CI 0.002-0.090). Maternal and perinatal outcomes are comparable with Kielland forceps, vacuum extraction, and manual rotation, with few serious adverse outcomes. With appropriate training mid-cavity rotational delivery can be practiced safely, including the use of Kielland forceps. © 2013 RCOG.

  11. An innovative intermittent-vacuum assisted thermophilic anaerobic digestion process for effective animal manure utilization and treatment.

    PubMed

    Zhang, Renchuan; Anderson, Erik; Addy, Min; Deng, Xiangyuan; Kabir, Fayal; Lu, Qian; Ma, Yiwei; Cheng, Yanling; Liu, Yuhuan; Chen, Paul; Ruan, Roger

    2017-11-01

    Intermittent-vacuum stripping (IVS) was developed as a pretreatment for thermophilic anaerobic digestion (TAD) to improve methanogenesis and hydrolysis activity through preventing free ammonia and hydrogen sulfide (H 2 S) inhibition from liquid swine manure (LSM). Over 98% of ammonia and 38% organic nitrogen were removed in 60min from 55°C to 85°C with vacuum pressure (from 100.63±3.79mmHg to 360.91±7.39mmHg) at initial pH 10.0 by IVS. Thermophilic methanogenesis and hydrolysis activity of pretreated LSM increased 52.25% (from 11.56±1.75% to 17.60±0.49%) in 25days and 40% (from 10days to 6days) in bio-methane potential assay. Over 80% H 2 S and total nitrogen were removed by IVS assistance, while around 70% nitrogen was recycled as ammonium sulfate. Therefore, IVS-TAD combination could be an effective strategy to improve TAD efficiency, whose elution is more easily utilized in algae cultivation and/or hydroponic system. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Comparison of intraocular pressure during the application of a liquid patient interface (FEMTO LDV Z8) for femtosecond laser-assisted cataract surgery using two different vacuum levels.

    PubMed

    Ebner, Martina; Mariacher, Siegfried; Januschowski, Kai; Boden, Katrin; Seuthe, Anna-Maria; Szurman, Peter; Boden, Karl Thomas

    2017-08-01

    To evaluate intraocular pressure (IOP) using the application of a novel liquid patient interface for femtosecond laser-assisted cataract surgery with the FEMTO LDV Z8. IOP was evaluated in enucleated porcine eyes prior, during and after the application of the Femto LDV Z8 liquid patient interface (Ziemer Ophthalmic Systems, Switzerland) using intracameral cannulation (n=20), intravitreal cannulation (n=20), rebound tonometry (n=20) and indentation tonometry (n=20). Pressure was assessed prior vacuum, during vacuum (30 s, 1 min, 2 min, 3 min) and after releasing the vacuum (1 min and 2 min). Two groups with different predefined vacuum levels (350 mbar, 420 mbar) were investigated. Mean intracameral pressure (±SD) increased during vacuum application from 20 mm Hg to 52.00 mm Hg (±6.35mm Hg; p=0.005) and 45.18 mmHg (±4.34 mm Hg; p=0.005) for the 420 mbar and the 350 mbar vacuum levels, respectively. Mean intravitreal pressure increased from 20 mm Hg to 25.60 mm Hg (±9.85 mm Hg; p=0.058) and 28.10 mm Hg (±2.54 mm Hg; p=0.059) for the 420 mbar and the 350 mbar vacuum levels, respectively. Pressure values from indentation and rebound tonometry were in between intracameral and intravitreal values. Mean intracameral IOP was 18.1% higher (p=0.019) in the 420 mbar group compared with the 350 mbar group. During vacuum application of the liquid patient interface of the Femto LDV Z8 for femtosecond laser-assisted cataract surgery, IOP values were higher in the anterior chamber compared with the intravitreal pressure measurements. The higher predefined vacuum level (350 mbar vs 420 mbar) resulted in significant higher intracameral IOP. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  13. Instrumental delivery: clinical practice guidelines from the French College of Gynaecologists and Obstetricians.

    PubMed

    Vayssière, Christophe; Beucher, Gael; Dupuis, Olivier; Feraud, Olivia; Simon-Toulza, Caroline; Sentilhes, Loïc; Meunier, Emmanuelle; Parant, Olivier; Schmitz, Thomas; Riethmuller, Didier; Baud, Olivier; Galley-Raulin, Fabienne; Diemunsch, Pierre; Pierre, Fabrice; Schaal, Jean-Patrick; Fournié, Alain; Oury, Jean François

    2011-11-01

    Routine use of a partograph is associated with a reduction in the use of forceps, but is not associated with a reduction in the use of vacuum extraction (Level A). Early artificial rupture of the membranes, associated with oxytocin perfusion, does not reduce the number of operative vaginal deliveries (Level A), but does increase the rate of fetal heart rate abnormalities (Level B). Early correction of lack of progress in dilatation by oxytocin perfusion can reduce the number of operative vaginal deliveries (Level B). The use of low-concentration epidural infusions of bupivacaine potentiated by morphinomimetics reduces the number of operative interventions compared with larger doses (Level A). Placement of an epidural before 3-cm dilatation does not increase the number of operative vaginal deliveries (Level A). Posterior positions of the fetus result in more operative vaginal deliveries (Level B). Manual rotation of the fetus from a posterior position to an anterior position may reduce the number of operative deliveries (Level C). Walking during labour is not associated with a reduction in the number of operative vaginal deliveries (Level A). Continuous support of the parturient by a midwife or partner/family member during labour reduces the number of operative vaginal deliveries (Level A). Under epidural analgesia, delayed pushing (2h after full dilatation) reduces the number of difficult operative vaginal deliveries (Level A). Ultrasound is recommended if there is any clinical doubt about the presentation of the fetus (Level B). The available scientific data are insufficient to contra-indicate attempted midoperative delivery (professional consensus). The duration of the operative intervention is slightly shorter with forceps than with a vacuum extractor (Level C). Nonetheless, the urgency of operative delivery is not a reason to choose one instrument over another (professional consensus). The cup-shaped vacuum extractor seems to be the instrument of choice for

  14. Computer assisted thermal-vacuum testing

    NASA Technical Reports Server (NTRS)

    Petrie, W.; Mikk, G.

    1977-01-01

    In testing complex systems and components under dynamic thermal-vacuum environments, it is desirable to optimize the environment control sequence in order to reduce test duration and cost. This paper describes an approach where a computer is utilized as part of the test control operation. Real time test data is made available to the computer through time-sharing terminals at appropriate time intervals. A mathematical model of the test article and environmental control equipment is then operated on using the real time data to yield current thermal status, temperature analysis, trend prediction and recommended thermal control setting changes to arrive at the required thermal condition. The data acquisition interface and the time-sharing hook-up to an IBM-370 computer is described along with a typical control program and data demonstrating its use.

  15. Magnetically assisted intraperitoneal drug delivery for cancer chemotherapy.

    PubMed

    Shamsi, Milad; Sedaghatkish, Amir; Dejam, Morteza; Saghafian, Mohsen; Mohammadi, Mehdi; Sanati-Nezhad, Amir

    2018-11-01

    Intraperitoneal (IP) chemotherapy has revived hopes during the past few years for the management of peritoneal disseminations of digestive and gynecological cancers. Nevertheless, a poor drug penetration is one key drawback of IP chemotherapy since peritoneal neoplasms are notoriously resistant to drug penetration. Recent preclinical studies have focused on targeting the aberrant tumor microenvironment to improve intratumoral drug transport. However, tumor stroma targeting therapies have limited therapeutic windows and show variable outcomes across different cohort of patients. Therefore, the development of new strategies for improving the efficacy of IP chemotherapy is a certain need. In this work, we propose a new magnetically assisted strategy to elevate drug penetration into peritoneal tumor nodules and improve IP chemotherapy. A computational model was developed to assess the feasibility and predictability of the proposed active drug delivery method. The key tumor pathophysiology, including a spatially heterogeneous construct of leaky vasculature, nonfunctional lymphatics, and dense extracellular matrix (ECM), was reconstructed in silico. The transport of intraperitoneally injected magnetic nanoparticles (MNPs) inside tumors was simulated and compared with the transport of free cytotoxic agents. Our results on magnetically assisted delivery showed an order of magnitude increase in the final intratumoral concentration of drug-coated MNPs with respect to free cytotoxic agents. The intermediate MNPs with the radius range of 200-300 nm yield optimal magnetic drug targeting (MDT) performance in 5-10 mm tumors while the MDT performance remains essentially the same over a large particle radius range of 100-500 nm for a 1 mm radius small tumor. The success of MDT in larger tumors (5-10 mm in radius) was found to be markedly dependent on the choice of magnet strength and tumor-magnet distance while these two parameters were less of a concern in small tumors

  16. Recent in vivo advances in cell-penetrating peptide-assisted drug delivery.

    PubMed

    Kurrikoff, Kaido; Gestin, Maxime; Langel, Ülo

    2016-01-01

    Delivery of macromolecular drugs is an important field in medical research. However, macromolecules are usually unable to cross the cell membrane without the assistance of a delivery system. Cell penetrating peptides (CPPs) are unique tools to gain access to the cell interior and deliver a bioactive cargo into the cytosol or nucleus. In addition to macromolecular delivery, CPPs have been used to deliver smaller bioactive molecules. Therefore CPPs have become an intensive field of research for medical treatment. In this review, we highlight studies that include CPP in vivo disease models. We review different strategies and approaches that have been used, with specific attention on recent publications. The approaches that have been used include CPP-cargo covalent conjugation strategies and nanoparticle strategies. Various additional strategies have been used to achieve disease targeting, including active targeting, passive targeting, and combined active/passive strategies. As a result, delivery of various types of molecule has been achieved, including small drug molecules, proteins and nucleic acid-based macromolecules (e.g. siRNA, antisense nucleotides and plasmid DNA). Despite recent advances in the field, confusions surrounding CPP internalization mechanisms and intracellular trafficking are hindering the development of new and more efficient vectors. Nevertheless, the recent increase in the number of publications containing in vivo CPP utilization looks promising that the number of clinical trials would also increase in the near future.

  17. Global Health Care Justice, Delivery Doctors and Assisted Reproduction: Taking a Note From Catholic Social Teachings.

    PubMed

    Richie, Cristina

    2015-12-01

    This article will examine the Catholic concept of global justice within a health care framework as it relates to women's needs for delivery doctors in the developing world and women's demands for assisted reproduction in the developed world. I will first discuss justice as a theory, situating it within Catholic social teachings. The Catholic perspective on global justice in health care demands that everyone have access to basic needs before elective treatments are offered to the wealthy. After exploring specific discrepancies in global health care justice, I will point to the need for delivery doctors in the developing world to provide basic assistance to women who hazard many pregnancies as a priority before offering assisted reproduction to women in the developed world. The wide disparities between maternal health in the developing world and elective fertility treatments in the developed world are clearly unjust within Catholic social teachings. I conclude this article by offering policy suggestions for moving closer to health care justice via doctor distribution. © 2014 John Wiley & Sons Ltd.

  18. Long-term clinical evaluation of a 800-nm long-pulsed diode laser with a large spot size and vacuum-assisted suction for hair removal.

    PubMed

    Ibrahimi, Omar A; Kilmer, Suzanne L

    2012-06-01

    The long-pulsed diode (800-810-nm) laser is one of the most commonly used and effective lasers for hair removal. Limitations of currently available devices include a small treatment spot size, treatment-associated pain, and the need for skin cooling. To evaluate the long-term hair reduction capabilities of a long-pulsed diode laser with a large spot size and vacuum assisted suction. Thirty-five subjects were enrolled in a prospective, self-controlled, single-center study of axillary hair removal. The study consisted of three treatments using a long-pulsed diode laser with a large spot size and vacuum-assisted suction at 4- to 6-week intervals with follow-up visits 6 and 15 months after the last treatment. Hair clearance was quantified using macro hair-count photographs taken at baseline and at 6- and 15-month follow-up visits. Changes in hair thickness and color, levels of treatment-associated pain, and adverse events were additional study endpoints. There was statistically significant hair clearance at the 6 (54%) and 15-month (42%) follow-up visits. Remaining hairs were thinner and lighter at the 15-month follow-up visit, and the majority of subjects reported feeling up to mild to moderate pain during treatment without the use of pretreatment anesthesia or skin cooling. A long-pulsed diode laser with a large spot size and vacuum-assisted suction is safe and effective for long-term hair removal. This is the largest prospective study to evaluate long-term hair removal and the first to quantify decreases in hair thickness and darkness with treatment. © 2012 by the American Society for Dermatologic Surgery, Inc. Published by Wiley Periodicals, Inc.

  19. Computer Assisted Rehabilitation Service Delivery.

    ERIC Educational Resources Information Center

    West Virginia Rehabilitation Research and Training Center, Dunbar.

    This volume consisting of state of the art reviews, suggestions and guidelines for practitioners, and program descriptions deals with the current and potential applications of computers in the delivery of services for vocational rehabilitation (VR). Discussed first are current applications of computer technology in rehabilitative service delivery.…

  20. A vacuum flash-assisted solution process for high-efficiency large-area perovskite solar cells

    NASA Astrophysics Data System (ADS)

    Li, Xiong; Bi, Dongqin; Yi, Chenyi; Décoppet, Jean-David; Luo, Jingshan; Zakeeruddin, Shaik Mohammed; Hagfeldt, Anders; Grätzel, Michael

    2016-07-01

    Metal halide perovskite solar cells (PSCs) currently attract enormous research interest because of their high solar-to-electric power conversion efficiency (PCE) and low fabrication costs, but their practical development is hampered by difficulties in achieving high performance with large-size devices. We devised a simple vacuum flash-assisted solution processing method to obtain shiny, smooth, crystalline perovskite films of high electronic quality over large areas. This enabled us to fabricate solar cells with an aperture area exceeding 1 square centimeter, a maximum efficiency of 20.5%, and a certified PCE of 19.6%. By contrast, the best certified PCE to date is 15.6% for PSCs of similar size. We demonstrate that the reproducibility of the method is excellent and that the cells show virtually no hysteresis. Our approach enables the realization of highly efficient large-area PSCs for practical deployment.

  1. High risk of fistula formation in vacuum-assisted closure therapy in patients with open abdomen due to secondary peritonitis-a retrospective analysis.

    PubMed

    Mintziras, Ioannis; Miligkos, Michael; Bartsch, Detlef Klaus

    2016-08-01

    The aim of this study was to evaluate the efficacy of vacuum-assisted closure therapy in patients with open abdomen due to secondary peritonitis and to identify possible risk factors of fistula formation. The hospital OPS-database (time period 2005-2014) was searched to identify patients treated with an open abdomen due to secondary peritonitis, who underwent vacuum-assisted closure therapy. Medical records were retrospectively analyzed for patients' characteristics, cause of peritonitis, duration of vacuum therapy, number of relaparotomies, fascial closure rates, and risk factors of fistula formation. Forty-three patients (19 male, 24 female) with a median age of 65 years (range 24-90 years) were identified. The major cause of secondary peritonitis was anastomotic leakage after intestinal anastomosis or bowel perforation, the median APACHE II score was 11. Median duration of VAC treatment was 12 days (range 3-88 days). Twenty of 43 (47 %) patients died from septic complications. Delayed fascial closure was obtained by suturing in 20 of 43 patients (47 %). Overall 16 of 43 (37 %) patients developed enteroatmospheric fistulas. Re-explorations after starting VAC treatment and duration of VAC therapy were significantly associated with the occurrence of enteroatmospheric fistulas (p < 0.001). ROC curve analysis determined the optimal duration of VAC therapy to reduce the risk of fistula formation at 13 days. Long-term VAC treatment of patients with an open abdomen due to secondary peritonitis results in a relatively low fascial closure rate and a high risk of fistula formation.

  2. Laser-assisted topical corticosteroid delivery for the treatment of keloids.

    PubMed

    Park, Ji Hye; Chun, Ji Young; Lee, Jong Hee

    2017-04-01

    Laser-assisted drug delivery has generated intense interest. The objectives of this study are to evaluate the clinical benefit of laser-assisted corticosteroid delivery and to compare this technique to corticosteroid intralesional injection, a standard treatment for keloids. Patients with keloids on the left shoulder after BCG vaccination were enrolled in this study. The entire lesion was first treated with an ablative fractional erbium-YAG laser. After this treatment, the lesion was divided into two halves. The first half received an intralesional injection of corticosteroid, whereas the second half received topical application of corticosteroids that were occluded for 3 hours. Four treatment sessions were conducted, with treatments occurring once every 6 weeks. Treatment outcomes were evaluated using the Vancouver Scar Scale (VSS). Pain was self-assessed by the patient during the procedure. The mean keloid VSS score before treatment was 8.59 ± 1.23 for the corticosteroid injection site and 8.31 ± 2.09 for the topical site. After treatment, the mean keloid VSS score was decreased on both sides (4.56 ± 1.09 vs 5.02 ± 0.87, respectively, P > 0.05). Patients rated their satisfaction level as "moderate" on both sides. However, the mean pain score was 1.1 out of 10 on the topical side versus 6.1 on the corticosteroid injection site. The combination of ablative fractional laser treatment and topical corticosteroid application is a promising modality for the treatment of keloids. Moreover, this procedure was not associated with any serious adverse reactions or unbearable pain.

  3. Cost effectiveness and efficiency in assistive technology service delivery.

    PubMed

    Warren, C G

    1993-01-01

    In order to develop and maintain a viable service delivery program, the realities of cost effectiveness and cost efficiency in providing assistive technology must be addressed. Cost effectiveness relates to value of the outcome compared to the expenditures. Cost efficiency analyzes how a provider uses available resources to supply goods and services. This paper describes how basic business principles of benefit/cost analysis can be used to determine cost effectiveness. In addition, basic accounting principles are used to illustrate methods of evaluating a program's cost efficiency. Service providers are encouraged to measure their own program's effectiveness and efficiency (and potential viability) in light of current trends. This paper is meant to serve as a catalyst for continued dialogue on this topic.

  4. [Dual chamber safety vacuum--initial experiences with a new suction cup].

    PubMed

    Korell, M; King, S; Hepp, H

    1994-06-01

    The main problem with vacuum extraction methods, alongside the cephalhaematoma produced, is the premature separation of the suction cup under traction, since the resulting sudden change in pressure can lead to severe intra-cerebral damage to the child. To reduce the risk of vaginal operative delivery, a new double-chamber safety vacuum extractor has been developed by Hepp/King. The basic feature of this instrument is an additional chamber with a thin overlapping area, which surrounds the actual suction cup and serves as a safety vacuum. If the suction cup starts to slip, the external vacuum is released and sounds an alarm. In addition, the inner vacuum has been designed to be convex and to reduce the volume of scalp, which is sucked into the vacuum, thus reducing the size of the cephalhaematoma produced. First experiences in clinical use demonstrated the reliability of the early warning signal, if the direction of traction is false or the applied traction is too strong. The inner vacuum remains constant at 0.8 atu, so that with care, the extraction can continue without interruption. We have used the new instrument in 18 deliveries. In 15 cases, the indication was failure to progress into the second stage of labour; in one case history of retinal detachment and in two cases signs of foetal asphyxia. In all cases, the child was delivered following one or two contractions with traction, without losing the vacuum. The average weight of the newborn was 3566 g. As expected, the cephalohaematoma produced was very much smaller than usual. Further clinical trials are necessary before the value of this new instrument can be assessed.

  5. Forceps delivery is associated with increased risk of pelvic organ prolapse and muscle trauma: a cross-sectional study 16-24 years after first delivery.

    PubMed

    Volløyhaug, I; Mørkved, S; Salvesen, Ø; Salvesen, K Å

    2015-10-01

    To study possible associations between mode of delivery and pelvic organ prolapse (POP) and pelvic floor muscle trauma 16-24 years after first delivery and, in particular, to identify differences between forceps and vacuum delivery. This was a cross-sectional study including 608 women who delivered their first child in 1990-1997 and were examined with POP quantification (POP-Q) and pelvic floor ultrasound in 2013-2014. Outcome measures were POP ≥ Stage 2 or previous prolapse surgery, levator avulsion and levator hiatal area on Valsalva. Univariable and multivariable logistic regression analyses and ANCOVA were applied to identify outcome variables associated with mode of delivery. Comparing forceps to vacuum delivery, the adjusted odds ratios (aOR) were 1.72 (95% CI, 1.06-2.79; P = 0.03) for POP ≥ Stage 2 or previous prolapse surgery and 4.16 (95% CI, 2.28-7.59; P < 0.01) for levator avulsion. Hiatal area on Valsalva was larger, with adjusted mean difference (aMD) of 4.75 cm(2) (95% CI, 2.46-7.03; P < 0.01). Comparing forceps with normal vaginal delivery, the adjusted odds ratio (aOR) was 1.74 (95% CI, 1.12-2.68; P = 0.01) for POP ≥ Stage 2 or surgery and 4.35 (95% CI, 2.56-7.40; P < 0.01) for levator avulsion; hiatal area on Valsalva was larger, with an aMD of 3.84 cm(2) (95% CI, 1.78-5.90; P < 0.01). Comparing Cesarean delivery with normal vaginal delivery, aOR was 0.06 (95% CI, 0.02-0.14; P < 0.01) for POP ≥ Stage 2 or surgery and crude OR was 0.00 (95% CI, 0.00-0.30; P < 0.01) for levator avulsion; hiatal area on Valsalva was smaller, with an aMD of -8.35 cm(2) (95% CI, -10.87 to -5.84; P < 0.01). No differences were found between vacuum and normal vaginal delivery. We found that mode of delivery was associated with POP and pelvic floor muscle trauma in women from a general population, 16-24 years after their first delivery. Forceps was associated with significantly more POP

  6. Providing assistive technology in Italy: the perceived delivery process quality as affecting abandonment.

    PubMed

    Federici, Stefano; Borsci, Simone

    2016-01-01

    The study brings together three aspects rarely observed at once in assistive technology (AT) surveys: (i) the assessment of user interaction/satisfaction with AT and service delivery, (ii) the motivational analysis of AT abandonment, and (iii) the management/design evaluation of AT delivery services. 15 health professionals and 4 AT experts were involved in modelling and assessing four AT Local Health Delivery Service (Centres) in Italy through a SWOT analysis and a Cognitive Walkthrough. In addition 558 users of the same Centres were interviewed in a telephone survey to rate their satisfaction and AT use. The overall AT abandonment was equal to 19.09%. Different Centres' management strategies resulted in different percentages of AT disuse, with a range from 12.61% to 24.26%. A significant difference between the declared abandonment and the Centres' management strategies (p = 0.012) was identified. A strong effect on abandonment was also found due to professionals' procedures (p = 0.005) and follow-up systems (p = 0.002). The user experience of an AT is affected not only by the quality of the interaction with the AT, but also by the perceived quality of the Centres in support and follow-up. Implications for Rehabilitation AT abandonment surveys provide useful information for modelling AT assessment and delivery process. SWOT and Cognitive Walkthrough analyses have shown suitable methods for exploring limits and advantages in AT service delivery systems. The study confirms the relevance of person centredness for a successful AT assessment and delivery process.

  7. Systematizing the Delivery of Local Employment and Training Services. The Job Center Technical Assistance Guide.

    ERIC Educational Resources Information Center

    Wisconsin State Dept. of Industry, Labor and Human Relations, Madison.

    This technical assistance guide was developed to consolidate a statewide understanding of the effort to systematize the delivery of employment and training programs through the local formation of job centers in Wisconsin, and to provide a compilation, drawn from 20 local models, that explains how the programs are delivered. The guide is organized…

  8. Mode of delivery and the probability of subsequent childbearing: a population-based register study.

    PubMed

    Elvander, C; Dahlberg, J; Andersson, G; Cnattingius, S

    2015-11-01

    To investigate the relationship between mode of first delivery and probability of subsequent childbearing. Population-based study. Nationwide study in Sweden. A cohort of 771 690 women who delivered their first singleton infant in Sweden between 1992 and 2010. Using Cox's proportional-hazards regression models, risks of subsequent childbearing were compared across four modes of delivery. Hazard ratios (HRs) were calculated, using 95% confidence intervals (95% CIs). Probability of having a second and third child; interpregnancy interval. Compared with women who had a spontaneous vaginal first delivery, women who delivered by vacuum extraction were less likely to have a second pregnancy (HR 0.96, 95% CI 0.95-0.97), and the probabilities of a second childbirth were substantially lower among women with a previous emergency caesarean section (HR 0.85, 95% CI 0.84-0.86) or an elective caesarean section (HR 0.82, 95% CI 0.80-0.83). There were no clinically important differences in the median time between first and second pregnancy by mode of first delivery. Compared with women younger than 30 years of age, older women were more negatively affected by a vacuum extraction with respect to the probability of having a second child. A primary vacuum extraction decreased the probability of having a third child by 4%, but having two consecutive vacuum extraction deliveries did not further alter the probability. A first delivery by vacuum extraction does not reduce the probability of subsequent childbearing to the same extent as a first delivery by emergency or elective caesarean section. © 2014 Royal College of Obstetricians and Gynaecologists.

  9. Fractional erbium-doped yttrium aluminum garnet laser-assisted drug delivery of hydroquinone in the treatment of melasma

    PubMed Central

    Badawi, Ashraf M; Osman, Mai Abdelraouf

    2018-01-01

    Background Melasma is a difficult-to-treat hyperpigmentary disorder. Ablative fractional laser (AFL)-assisted delivery of topically applied drugs to varied targets in the skin has been an area of ongoing study and research. Objective The objective of this study was to evaluate the efficacy and safety of fractional erbium-doped yttrium aluminum garnet (Er:YAG) laser as an assisted drug delivery for enhancing topical hydroquinone (HQ) permeation into the skin of melasma patients. Patients and methods Thirty female patients with bilateral melasma were randomly treated in a split-face controlled manner with a fractional Er:YAG laser followed by 4% HQ cream on one side and 4% HQ cream alone on the other side. All patients received six laser sessions with a 2-week interval. The efficacy of treatments was determined through photographs, dermoscopic photomicrographs and Melasma Area Severity Index (MASI) score, all performed at baseline and at 12 weeks of starting therapy. The patient’s level of satisfaction was also recorded. Results Er:YAG laser + HQ showed significantly better results (p<0.005) with regard to decrease in the degree of pigmentation as assessed on the 4-point scale than HQ alone. There was a significant decrease in MASI scores on Er:YAG laser + HQ side vs HQ side. Minor reversible side effects were observed on both sides. Conclusion AFL-assisted delivery of HQ is a safe and effective method for the treatment of melasma. PMID:29379308

  10. Determinants of Skilled Delivery Assistance in a Rural Population: Findings from an HDSS Site of Rural West Bengal, India.

    PubMed

    Ghosh, Saswata; Siddiqui, Md Zakaria; Barik, Anamitra; Bhaumik, Sunil

    2015-11-01

    This study examines the determinants of utilisation of skilled birth attendants (SBAs) amongst 2886 rural women in the state of West Bengal, India, using data from a survey of 2012-2013 conducted by the Birbhum Health and Demographic Surveillance System. Multilevel logit regression models were estimated and qualitative investigations conducted to understand the determinants of utilisation of SBAs in rural West Bengal. Among women who delivered their last child during the 3 years preceding the survey, 69.1 % of deliveries were assisted by SBAs, while 30.9 % were home deliveries without any SBA assistance. Multivariate analysis revealed that apart from socio-demographic and economic factors (such as household affluence, women's education, birth order, uptake of comprehensive ANC check-ups, advice regarding danger signs of pregnancy and household's socio-religious affiliation), supply side factors, such as availability of skilled birth attendants in the village and all-weather roads, have significant effect on seeking skilled assistance. Our findings also show that unobserved factors at village level independently influence uptake of SBA-assisted delivery. The present findings emphasise that both demand and supply side intervention strategies are essential prerequisites to enhance skilled birth attendance. Ample communication is observed at the individual level, but improving community level outreach and advocacy activities could generate further demand. SBAs can be better integrated by accommodating the socio-religious needs of local communities, such as providing female doctors and doctors with similar socio-religious backgrounds.

  11. Edison's vacuum technology patents

    NASA Astrophysics Data System (ADS)

    Waits, Robert K.

    2003-07-01

    During 1879 Thomas Edison's Menlo Park, New Jersey laboratory developed the means to evacuate glass lamp globes to less than a mTorr in 20 min and in mid-1880 began production of carbon-filament incandescent lamps. Among Edison's nearly 1100 U.S. patents are five for vacuum pump improvements, and at least eight others that are vacuum-related; all applied for between 1880 and 1886. Inspired by an 1878 article by De La Rue and Müller [Philos. Trans. R. Soc. London, Ser. A 169, 155 (1878)] on studies of glow discharges, Edison devised a combination pump using the Geissler pump as a rough pump and the Sprengel pump for continuous exhaustion. Edison's patents described means to control the mercury flow and automate the delivery of the mercury to banks of up to a hundred pumps. Other patents described various means to remove residual gases during lamp processing.

  12. Method and apparatus for performing in-situ vacuum-assisted metal to glass sealing

    DOEpatents

    Kramer, D.P.; Massey, R.T.

    1985-07-18

    A method and apparatus for assembling and fusing glass to metal in a glass-metal electrical component is disclosed. The component includes a metallic shell formed with upper and lower cylindrical recesses connected together by longitudinal passages, a pair of metal rings and plural metal pins assembled to define electrical feed-throughs. The component parts are assembled on a fixture having a sleeve-like projection and a central mounting projection establishing concentric nesting surfaces to which the metal rings are slip-fitted in concentric alignment with each other spaced from sidewalls of the lower recess. The pins are in electrical contact with the metal rings. A glass pre-form is seated within the upper recess. The assembled structure is heated to a temperature sufficient to melt the glass pre-form which flows under gravity through the passages into the lower recess to provide an insulative seal between the metal parts. The gravity flow of glass is assisted by applying vacuum to the lower recess, ensuring that all spaces between the metal parts are filled with sealing glass without formation of bubbles.

  13. Method and apparatus for performing in-situ vacuum-assisted metal to glass sealing

    DOEpatents

    Kramer, Daniel P.; Massey, Richard T.

    1986-01-01

    A method and apparatus for assembling and fusing glass to metal in a glass-metal electrical component is disclosed. The component includes a metallic shell formed with upper and lower cylindrical recesses connected together by longitudinal passages, a pair of metal rings and plural metal pins assembled to define electrical feed-throughs. The component parts are assembled on a fixture having a sleeve-like projection and a central mounting projection establishing concentric nesting surfaces to which the metal rings are slip-fitted in concentric alignment with each other spaced from sidewalls of the lower recess. The pins are in electrical contact with the metal rings. A glass pre-form is seated within the upper recess. The assembled structure is heated to a temperature sufficient to melt the glass pre-form which flows under gravity through the passages into the lower recess to provide an insulative seal between the metal parts. The gravity flow of glass is assisted by applying vacuum to the lower recess, ensuring that all spaces between the metal parts are filled with sealing glass without formation of bubbles.

  14. Innovative Technology for the Assisted Delivery of Intensive Voice Treatment (LSVT[R]LOUD) for Parkinson Disease

    ERIC Educational Resources Information Center

    Halpern, Angela E.; Ramig, Lorraine O.; Matos, Carlos E. C.; Petska-Cable, Jill A.; Spielman, Jennifer L.; Pogoda, Janice M.; Gilley, Phillip M.; Sapir, Shimon; Bennett, John K.; McFarland, David H.

    2012-01-01

    Purpose: To assess the feasibility and effectiveness of a newly developed assistive technology system, Lee Silverman Voice Treatment Companion (LSVT[R] Companion[TM], hereafter referred to as "Companion"), to support the delivery of LSVT[R]LOUD, an efficacious speech intervention for individuals with Parkinson disease (PD). Method: Sixteen…

  15. The impact of occiput posterior fetal head position on the risk of anal sphincter injury in forceps-assisted vaginal deliveries.

    PubMed

    Benavides, Lorena; Wu, Jennifer M; Hundley, Andrew F; Ivester, Thomas S; Visco, Anthony G

    2005-05-01

    A forceps-assisted vaginal delivery is a well-recognized risk factor for anal sphincter injury. Some studies have shown that occiput posterior (OP) fetal head position is also associated with an increased risk for third- or fourth-degree lacerations. The objective of this study was to assess whether OP position confers an incrementally increased risk for anal sphincter injury above that present with forceps deliveries. This was a retrospective cohort study of 588 singleton, cephalic, forceps-assisted vaginal deliveries performed at our institution between January 1996 and October 2003. Maternal demographics, labor and delivery characteristics, and neonatal factors were examined. Statistical analysis consisted of univariate statistics, Student t test, chi2, and logistic regression. The prevalence of occiput anterior (OA) and OP positions was 88.4% and 11.6%, respectively. The groups were similar in age, marital status, body mass index, use of epidural, frequency of inductions, episiotomies, and shoulder dystocias. The OA group had a higher frequency of rotational forceps (16.2% vs 5.9%, P = .03), greater birth weights (3304 +/- 526 g vs 3092 +/- 777 g, P = .004), and a larger percentage of white women (48.8% vs 34.3%, P = .04). Overall, 35% of forceps deliveries resulted in a third- or fourth-degree laceration. Anal sphincter injury occurred significantly more often in the OP group compared with the OA group (51.5% vs 32.9%, P = .003), giving an odds ratio of 2.2 (CI: 1.3-3.6). In a logistic regression model that controlled for occiput posterior position, maternal body mass index, race, length of second stage, episiotomy, birth weight, and rotational forceps, OP head position was 3.1 (CI: 1.6-6.2) times more likely to be associated with anal sphincter injury than OA head position. Forceps-assisted vaginal deliveries have been associated with a greater risk for anal sphincter injury. Within this population of forceps deliveries, an OP position further increases the

  16. Application of ionic liquids in vacuum microwave-assisted extraction followed by macroporous resin isolation of three flavonoids rutin, hyperoside and hesperidin from Sorbus tianschanica leaves.

    PubMed

    Gu, Huiyan; Chen, Fengli; Zhang, Qiang; Zang, Jing

    2016-03-01

    Rutin, hyperoside and hesperidin were effectively extracted from Sorbus tianschanica leaves by an ionic liquid vacuum microwave-assisted method. A series of ionic liquids with various anions and alkyl chain length of the cations were studied and the extraction was performed in [C6mim][BF4] aqueous solution. After optimization by a factorial design and response surface methodology, total extraction yield of 2.37mg/g with an error of 0.12mg/g (0.71±0.04mg/g, 1.18±0.06mg/g and 0.48±0.02 for rutin, hyperoside and hesperidin, respectively) was achieved under -0.08MPa for vacuum, 19min and 420W for microwave irradiation time and power, and 15mL/g for liquid-solid ratio. The proposed method here is more efficient and needs a shorter extraction time for rutin, hyperoside and hesperidin from S. tianschanica leaves than reference extraction techniques. In stability studies performed with standard rutin, hyperoside and hesperidin, the target analytes were stable under the optimum conditions. The proposed method had a high reproducibility and precision. In addition, separation of rutin, hyperoside and hesperidin from [C6mim][BF4] extraction solution was completed effectively by AB-8 macroporous resin adsorption and desorption process. Ionic liquid vacuum microwave-assisted extraction is a simple, rapid and efficient sample extraction technique. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Recent advances in vacuum sciences and applications

    NASA Astrophysics Data System (ADS)

    Mozetič, M.; Ostrikov, K.; Ruzic, D. N.; Curreli, D.; Cvelbar, U.; Vesel, A.; Primc, G.; Leisch, M.; Jousten, K.; Malyshev, O. B.; Hendricks, J. H.; Kövér, L.; Tagliaferro, A.; Conde, O.; Silvestre, A. J.; Giapintzakis, J.; Buljan, M.; Radić, N.; Dražić, G.; Bernstorff, S.; Biederman, H.; Kylián, O.; Hanuš, J.; Miloševič, S.; Galtayries, A.; Dietrich, P.; Unger, W.; Lehocky, M.; Sedlarik, V.; Stana-Kleinschek, K.; Drmota-Petrič, A.; Pireaux, J. J.; Rogers, J. W.; Anderle, M.

    2014-04-01

    Recent advances in vacuum sciences and applications are reviewed. Novel optical interferometer cavity devices enable pressure measurements with ppm accuracy. The innovative dynamic vacuum standard allows for pressure measurements with temporal resolution of 2 ms. Vacuum issues in the construction of huge ultra-high vacuum devices worldwide are reviewed. Recent advances in surface science and thin films include new phenomena observed in electron transport near solid surfaces as well as novel results on the properties of carbon nanomaterials. Precise techniques for surface and thin-film characterization have been applied in the conservation technology of cultural heritage objects and recent advances in the characterization of biointerfaces are presented. The combination of various vacuum and atmospheric-pressure techniques enables an insight into the complex phenomena of protein and other biomolecule conformations on solid surfaces. Studying these phenomena at solid-liquid interfaces is regarded as the main issue in the development of alternative techniques for drug delivery, tissue engineering and thus the development of innovative techniques for curing cancer and cardiovascular diseases. A review on recent advances in plasma medicine is presented as well as novel hypotheses on cell apoptosis upon treatment with gaseous plasma. Finally, recent advances in plasma nanoscience are illustrated with several examples and a roadmap for future activities is presented.

  18. Design and assembly of new non-viral RNAi delivery agents by microwave-assisted quaternization (MAQ) of tertiary amines

    PubMed Central

    Ghosh, Animesh; Mukherjee, Koushik; Jiang, Xinpeng; Zhou, Ying; McCarroll, Joshua; Qu, James; Swain, Pamela M.; Baigude, Huricha; Rana, Tariq M.

    2010-01-01

    RNA interference (RNAi), a gene-silencing phenomenon whereby double-stranded RNA (dsRNA) triggers the sequence-specific degradation of homologous mRNA. RNAi has been quickly and widely applied to discover gene functions and holds great potential to provide a new class of therapeutic agents. However, new chemistry and delivery approaches are greatly needed to silence disease-causing genes without toxic effects. We reasoned that conjugation of the cholesterol moiety to cationic lipids would enhance RNAi efficiencies and lower the toxic effects of lipid-mediated RNAi delivery. Here, we report the first design and synthesis of new cholesterol-conjugated cationic lipids for RNAi delivery using microwave-assisted quaternization (MAQ) of tertiary amines. This strategy can be employed to develop new classes of non-viral gene delivery agents under safe and fast reaction conditions. PMID:20722369

  19. Vacuum extraction failure is associated with a large head circumference.

    PubMed

    Kabiri, Doron; Lipschuetz, Michal; Cohen, Sarah M; Yagel, Oren; Levitt, Lorinne; Herzberg, Shmuel; Ezra, Yossef; Yagel, Simcha; Amsalem, Hagai

    2018-04-24

    To determine whether large head circumference increases the risk of vacuum extraction failure. This EMR-based study included all attempted vacuum extractions performed in a tertiary center between January 2010 and June 2015. All term singleton live births were eligible. Cases were divided into four groups: head circumference ≥90th percentile both with birth weight ≥90th percentile and <90th percentile and fetal head circumference <90th percentile with birth weight ≥90th and <90th percentile. Risk of failed vacuum extraction was compared among these groups. Other neonatal and maternal parameters were also evaluated as potential risk factors. Multinomial multivariable regression provided adjusted odds ratio for vacuum extraction failure while controlling for potential confounders. During the study period, 48,007 deliveries met inclusion criteria, of which 3835 had an attempt at vacuum extraction. We identified 215 (5.6%) cases of vacuum extraction failure. The adjusted odds ratios (aOR) for vacuum extraction failure in cases of large fetal head circumference was 2.31 (95%CI, 1.7-3.15, p < .001). Primiparity, prolonged second stage and occipito-posterior presentation were also found to be significant risk factors for failed vacuum extraction. In this study, we found that large head circumference was associated with vacuum extraction failure rather than high birth weight.

  20. Overall Quality of Fruits and Vegetables Products Affected by the Drying Processes with the Assistance of Vacuum-Microwaves.

    PubMed

    Figiel, Adam; Michalska, Anna

    2016-12-30

    The seasonality of fruits and vegetables makes it impossible to consume and use them throughout the year, thus numerous processing efforts have been made to offer an alternative to their fresh consumption and application. To prolong their availability on the market, drying has received special attention as currently this method is considered one of the most common ways for obtaining food and pharmaceutical products from natural sources. This paper demonstrates the weakness of common drying methods applied for fruits and vegetables and the possible ways to improve the quality using different drying techniques or their combination with an emphasis on the microwave energy. Particular attention has been drawn to the combined drying with the assistance of vacuum-microwaves. The quality of the dried products was ascribed by chemical properties including the content of polyphenols, antioxidant capacity and volatiles as well as physical parameters such as color, shrinkage, porosity and texture. Both these fields of quality classification were considered taking into account sensory attributes and energy aspects in the perspective of possible industrial applications. In conclusion, the most promising way for improving the quality of dried fruit and vegetable products is hybrid drying consisting of osmotic dehydration in concentrated fruit juices followed by heat pump drying and vacuum-microwave finish drying.

  1. Overall Quality of Fruits and Vegetables Products Affected by the Drying Processes with the Assistance of Vacuum-Microwaves

    PubMed Central

    Figiel, Adam; Michalska, Anna

    2016-01-01

    The seasonality of fruits and vegetables makes it impossible to consume and use them throughout the year, thus numerous processing efforts have been made to offer an alternative to their fresh consumption and application. To prolong their availability on the market, drying has received special attention as currently this method is considered one of the most common ways for obtaining food and pharmaceutical products from natural sources. This paper demonstrates the weakness of common drying methods applied for fruits and vegetables and the possible ways to improve the quality using different drying techniques or their combination with an emphasis on the microwave energy. Particular attention has been drawn to the combined drying with the assistance of vacuum-microwaves. The quality of the dried products was ascribed by chemical properties including the content of polyphenols, antioxidant capacity and volatiles as well as physical parameters such as color, shrinkage, porosity and texture. Both these fields of quality classification were considered taking into account sensory attributes and energy aspects in the perspective of possible industrial applications. In conclusion, the most promising way for improving the quality of dried fruit and vegetable products is hybrid drying consisting of osmotic dehydration in concentrated fruit juices followed by heat pump drying and vacuum-microwave finish drying. PMID:28042845

  2. Imprint cytology on microcalcifications excised by vacuum-assisted breast biopsy: a rapid preliminary diagnosis.

    PubMed

    Fotou, Maria; Oikonomou, Vassiliki; Zagouri, Flora; Sergentanis, Theodoros N; Nonni, Afroditi; Athanassiadou, Pauline; Drouveli, Theodora; Atsouris, Efstratios; Kotzia, Evagelia; Zografos, George C

    2007-04-03

    To evaluate imprint cytology in the context of specimens with microcalcifications derived from Vacuum-Assisted Breast Biopsy (VABB). A total of 93 women with microcalcifications BI-RADS 3 and 4 underwent VABB and imprint samples were examined. VABB was performed on Fischer's table using 11-gauge Mammotome vacuum probes. A mammogram of the cores after the procedure confirmed the excision of microcalcifications. For the application of imprint cytology, the cores with microcalcifications confirmed by mammogram were gently rolled against glass microscope slides and thus imprint smears were made. For rapid preliminary diagnosis Diff-Quick stain, modified Papanicolaou stain and May Grunwald Giemsa were used. Afterwards, the core was dipped into a CytoRich Red Collection fluid for a few seconds in order to obtain samples with the use of the specimen wash. After the completion of cytological procedures, the core was prepared for routine histological study. The pathologist was blind to the preliminary cytological results. The cytological and pathological diagnoses were comparatively evaluated. According to the pathological examination, 73 lesions were benign, 15 lesions were carcinomas (12 ductal carcinomas in situ, 3 invasive ductal carcinomas), and 5 lesions were precursor: 3 cases of atypical ductal hyperplasia (ADH) and 2 cases of lobular neoplasia (LN). The observed sensitivity and specificity of the cytological imprints for cancer were 100% (one-sided, 97.5% CI: 78.2%-100%). Only one case of ADH could be detected by imprint cytology. Neither of the two LN cases was detected by the imprints. The imprints were uninformative in 11 out of 93 cases (11.8%). There was no uninformative case among women with malignancy. Imprint cytology provides a rapid, accurate preliminary diagnosis in a few minutes. This method might contribute to the diagnosis of early breast cancer and possibly attenuates patients' anxiety.

  3. An ultrahigh vacuum, low-energy ion-assisted deposition system for III-V semiconductor film growth

    NASA Astrophysics Data System (ADS)

    Rohde, S.; Barnett, S. A.; Choi, C.-H.

    1989-06-01

    A novel ion-assisted deposition system is described in which the substrate and growing film can be bombarded with high current densities (greater than 1 mA/sq cm) of very low energy (10-200 eV) ions. The system design philosophy is similar to that used in III-V semiconductor molecular-beam epitaxy systems: the chamber is an all-metal ultrahigh vacuum system with liquid-nitrogen-cooled shrouds, Knudsen-cell evaporation sources, a sample insertion load-lock, and a 30-kV reflection high-energy electron diffraction system. III-V semiconductor film growth is achieved using evaporated group-V fluxes and group-III elemental fluxes sputtered from high-purity targets using ions extracted from a triode glow discharge. Using an In target and an As effusion cell, InAs deposition rates R of 2 microns/h have been obtained. Epitaxial growth of InAs was observed on both GaSb(100) and Si(100) substrates.

  4. Aerosol Vacuum-Assisted Plasma Ionization (Aero-VaPI) Coupled to Ion Mobility-Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Blair, Sandra L.; Ng, Nga L.; Zambrzycki, Stephen C.; Li, Anyin; Fernández, Facundo M.

    2018-02-01

    In this communication, we report on the real-time analysis of organic aerosol particles by Vacuum-assisted Plasma Ionization-Mass Spectrometry (Aero-VaPI-MS) using a home-built VaPI ion source coupled to a Synapt G2-S HDMS ion mobility-mass spectrometry (IM-MS) system. Standards of organic molecules of interest in prebiotic chemistry were used to generate aerosols. Monocaprin and decanoic acid aerosol particles were successfully detected in both the positive and negative ion modes, respectively. A complex aerosol mixture of different sizes of polymers of L-malic acid was also examined through ion mobility (IM) separations, resulting in the detection of polymers of up to eight monomeric units. This noncommercial plasma ion source is proposed as a low cost alternative to other plasma ionization platforms used for aerosol analysis, and a higher-performance alternative to more traditional aerosol mass spectrometers. VaPI provides robust online ionization of organics in aerosols without extensive ion activation, with the coupling to IM-MS providing higher peak capacity and excellent mass accuracy. [Figure not available: see fulltext.

  5. Irinotecan delivery by microbubble-assisted ultrasound - A pilot preclinical study

    NASA Astrophysics Data System (ADS)

    Escoffre, Jean-Michel; Novell, Anthony; Serrière, Sophie; Bouakaz, Ayache

    2012-11-01

    Irinotecan is conventionally used for the treatment of colorectal cancer. However, its administration is associated with severe side effects. Targeted drug delivery using ultrasound (US) combined with microbubbles offers new opportunities to increase the therapeutic effectiveness of antitumor treatment and to reduce toxic exposure to healthy tissues. The objective of this study is to investigate the safety and efficacy of in-vivo delivery of irinotecan by microbubble-assisted US in human glioblastoma model (U-87 MG). In order to validate the potential of this new method in-vivo, subcutaneous tumors were implanted in the flank of nude mouse and treated when they reached a volume of 100 mm3. In the first study, the measured volumes with caliper and anatomic ultrasound imaging were compared for the monitoring and the quantification of tumor growth during 27 days. Ultrasound imaging measurements were positively correlated to caliper measurements. The tumor treatment consisted of an i.v. injection of irinotecan (20 mg/kg) followed one hour later by i.v. administration of MM1 microbubble and an US insonation using a single-element transducer operating at 1MHz (400 kPa, 10 kHz PRF 40% DC, 3 min). The therapeutic efficacy was evaluated for 39 days by measuring the tumor volume before and after treatment using a caliper and based on ultrasound images using an 18 MHz probe (Vevo 2100). Our results showed that anatomical ultrasound imaging was as efficient as caliper for the monitoring and the quantification of tumor growth. Moreover, irinotecan delivery by sonoporation induced a significant decrease of glioblastoma tumor volume and an increase of tumor-doubling time compared to the tumor treated by irinotecan alone. In conclusion, this novel therapeutic approach has promising features since it can be used to reduce the injected drug dose and to achieve a better therapeutic efficacy.

  6. Resin Flow Behavior Simulation of Grooved Foam Sandwich Composites with the Vacuum Assisted Resin Infusion (VARI) Molding Process

    PubMed Central

    Zhao, Chenhui; Zhang, Guangcheng; Wu, Yibo

    2012-01-01

    The resin flow behavior in the vacuum assisted resin infusion molding process (VARI) of foam sandwich composites was studied by both visualization flow experiments and computer simulation. Both experimental and simulation results show that: the distribution medium (DM) leads to a shorter molding filling time in grooved foam sandwich composites via the VARI process, and the mold filling time is linearly reduced with the increase of the ratio of DM/Preform. Patterns of the resin sources have a significant influence on the resin filling time. The filling time of center source is shorter than that of edge pattern. Point pattern results in longer filling time than of linear source. Short edge/center patterns need a longer time to fill the mould compared with Long edge/center sources.

  7. Values of pathological analysis of lost tissue fragments in the vacuum canister during a vacuum-assisted stereotactic biopsy of the breast.

    PubMed

    El Khoury, M; Mesurolle, B; Omeroglu, A; Aldis, A; Kao, E

    2013-05-01

    Determine values of pathological analysis of the canister content during a vacuum-assisted breast biopsy (VABB). Approval was obtained from the ethical committee. Prospective radiological and pathological analyses of the canister content collected during 231 VABBs performed on 231 patients were carried out. χ(2) test was used to determine predictors on canister pathology. The canister pathology was reported separately in 212 cases. It showed only blood in 78/212 (37%) cases and benign (including high-risk lesions) and malignant results in, respectively, 113/212 (53%) and 21/212 (10%) cases. Respective specimen analysis was benign, including high-risk lesions in 162/212 cases (76%) and malignant in 50/212 (24%) cases. Microcalcifications were documented on canister X-ray in 70/231 (30%) cases. There was significant association between the canister and the specimen pathology (p<0.0001). In none of the cases was microcalcifications seen exclusively in the canister content or pathological upgrading found in the canister content compared with the specimen. Small tissue fragments and microcalcifications may be lost in the canister during a VABB. Nevertheless, our results did not show any significant value for systematic analysis of the canister content. There is no added diagnostic value to retrieval and analysis of tissue lost in the canister during a VABB.

  8. Training Nonnursing Staff to Assist with Nutritional Care Delivery in Nursing Homes: A Cost-Effectiveness Analysis.

    PubMed

    Simmons, Sandra F; Hollingsworth, Emily K; Long, Emily A; Liu, Xulei; Shotwell, Matthew S; Keeler, Emmett; An, Ruopeng; Silver, Heidi J

    2017-02-01

    To determine the effect and cost-effectiveness of training nonnursing staff to provide feeding assistance for nutritionally at-risk nursing home (NH) residents. Randomized, controlled trial. Five community NHs. Long-stay NH residents with an order for caloric supplementation (N = 122). Research staff provided an 8-hour training curriculum to nonnursing staff. Trained staff were assigned to between-meal supplement or snack delivery for the intervention group; the control group received usual care. Research staff used standardized observations and weighed-intake methods to measure frequency of between-meal delivery, staff assistance time, and resident caloric intake. Fifty staff (mean 10 per site) completed training. The intervention had a significant effect on between-meal caloric intake (F = 56.29, P < .001), with the intervention group consuming, on average, 163.33 (95% CI = 120.19-206.47) calories per person per day more than the usual care control group. The intervention costs were $1.27 per person per day higher than usual care (P < .001). The incremental cost-effectiveness ratio for the intervention was 134 kcal per dollar. The increase in cost was due to the higher frequency and number of snack items given per person per day and the associated staff time to provide assistance. It is cost effective to train nonnursing staff to provide caloric supplementation, and this practice has a positive effect on residents' between-meal intake. © 2016, Copyright the Authors Journal compilation © 2016, The American Geriatrics Society.

  9. A conservation ontology and knowledge base to support delivery of technical assistance to agricultural producers in the united states

    USDA-ARS?s Scientific Manuscript database

    Information systems supporting the delivery of conservation technical assistance by the United States Department of Agriculture (USDA) to agricultural producers on working lands have become increasingly complex over the past 25 years. They are constrained by inconsistent coordination of domain knowl...

  10. Evaluation of rapid readout biological indicators for 132 degrees C gravity and 132 degrees C vacuum-assisted steam sterilization cycles using a new automated fluorescent reader.

    PubMed

    Alfa, Michelle J; Olson, Nancy; DeGagne, Pat; Jackson, Michele

    2002-07-01

    The primary objective of this study was to evaluate fluorescent readout results of Attest 1291 Biological Indicators (BIs) (3M Health Care, St. Paul, MN) and Attest 1296 BI test packs (containing Attest 1292 BIs) using full and fractional cycles compared with the growth data when prolonged incubation (7 days) was included. Gravity displacement and vacuum-assisted steam sterilization cycles were evaluated. A secondary objective of this study was to evaluate the new automated rapid fluorescent reader (Attest 290 Auto Reader). The rapid readout BIs for gravity displacement and vacuum-assisted steam autoclave cycles at 132 degrees C were processed using full (4 minutes) and four fractional cycles that provided 30% to 80% positive results for growth after 24 hours of incubation (48 hours of incubation for Attest 1292 BIs from the Attest 1296 test packs). Sixty of each type of BI were tested for each cycle (300 of each BI type in total). For all full steam sterilization cycles, results of the rapid fluorescent readout and the 24-hour, 48-hour, and 7-day growth tests were negative for all Attest 1291 and 1292 BIs tested. For all fractional cycles, the 24- and 48-hour growth results for the Attest 1291 and 1292 BIs, respectively, were the same as the 7-day growth results. The fractional cycle data indicated that fluorescent rapid readout was a more sensitive indicator than growth. There were rare (0.9%) false-negative results for BIs under fractional cycle conditions and these all correlated with short fractional cycle exposure times. The fluorescent rapid readout results of the 1291 BIs and 1296 BI test packs reliably predict both 24- and 48-hour and 7-day growth. These data support the value of rapid readout BIs for sterilizer monitoring for both the vacuum-assisted and the gravity displacement steam sterilization cycles. The new automated reader requires less manipulation of the BI and makes monitoring user friendly and less prone to user errors.

  11. Processing and Properties of Vacuum Assisted Resin Transfer Molded Phenylethynyl Terminated Imide Composites

    NASA Technical Reports Server (NTRS)

    Cano, Roberto J.; Ghose, Sayata; Watson, Kent A.; Chunchu, Prasad B.; Jensen, Brian J.; Connell, John W.

    2012-01-01

    Polyimide composites are very attractive for applications that require a high strength to weight ratio and thermal stability. Recent work at NASA Langley Research Center (LaRC) has concentrated on developing new polyimide resin systems that can be processed without the use of an autoclave for advanced aerospace applications. Due to their low melt viscosities and long melt stability, certain phenylethynyl terminated imides (PETI) can be processed into composites using high temperature vacuum assisted resin transfer molding (HT-VARTM). VARTM has shown the potential to reduce the manufacturing cost of composite structures. In the current study, two PETI resins, LARC(Trademark) PETI-330 and LARC(Trademark) PETI-9, were infused into carbon fiber preforms at 260 C and cured at temperatures up to 371 C. Photomicrographs of polished cross sections were taken and void contents, determined by acid digestion, were below 4.5%. Mechanical properties including short block compression (SBC), compression after impact (CAI), and open hole compression (OHC) were determined at room temperature, 177 C, and 288 C. Both PETI-9 and PETI-330 composites demonstrated very good retention of mechanical properties at elevated temperatures. SBC and OHC properties after aging for 1000 hours at temperatures up to 288 C were also determined.

  12. Vacuum force

    NASA Astrophysics Data System (ADS)

    Han, Yongquan

    2015-03-01

    To study on vacuum force, we must clear what is vacuum, vacuum is a space do not have any air and also ray. There is not exist an absolute the vacuum of space. The vacuum of space is relative, so that the vacuum force is relative. There is a certain that vacuum vacuum space exists. In fact, the vacuum space is relative, if the two spaces compared to the existence of relative vacuum, there must exist a vacuum force, and the direction of the vacuum force point to the vacuum region. Any object rotates and radiates. Rotate bend radiate- centripetal, gravity produced, relative gravity; non gravity is the vacuum force. Gravity is centripetal, is a trend that the objects who attracted wants to Centripetal, or have been do Centripetal movement. Any object moves, so gravity makes the object curve movement, that is to say, the radiation range curve movement must be in the gravitational objects, gravity must be existed in non vacuum region, and make the object who is in the region of do curve movement (for example: The earth moves around the sun), or final attracted in the form gravitational objects, and keep relatively static with attract object. (for example: objects on the earth moves but can't reach the first cosmic speed).

  13. Consumer-Directed Goal Planning in the Delivery of Assistive Technology Services for People Who Are Ageing with Intellectual Disabilities

    ERIC Educational Resources Information Center

    Mirza, Mansha; Hammel, Joy

    2009-01-01

    Background: A consumer-directed service-delivery approach to assistive technology and environmental modification intervention was examined with people who were ageing with intellectual disabilities. Material and Methods: The intervention was based on a collaborative approach involving consumers, their social supports and service deliverers. Thirty…

  14. Translational medicine in the field of ablative fractional laser (AFXL)-assisted drug delivery: A critical review from basics to current clinical status.

    PubMed

    Haedersdal, Merete; Erlendsson, Andrés M; Paasch, Uwe; Anderson, R Rox

    2016-05-01

    Ablative fractional lasers enhance uptake of topical therapeutics and the concept of fractional laser-assisted drug delivery has now been taken into clinical practice. We systematically reviewed preclinical data and clinical evidence for fractional lasers to enhance drug uptake and improve clinical efficacy. We searched PubMed and Embase databases; 34 articles met the inclusion criteria. Studies were categorized into experimental preclinical studies and clinical trials, the latter graded according to level of evidence. All preclinical trials (n = 16) documented enhanced topical drug uptake into skin after ablative fractional laser treatment. Clinical evidence encompassed 18 studies, of which 9 were randomized controlled trials and 2 were controlled trials, examining neoplastic lesions, photodamaged skin, scars, onychomycosis, and topical anesthetics. The highest level of evidence was reached for actinic keratoses treated with methylaminolevulinate for photodynamic therapy (level IB, 5 randomized controlled trials), substantiating superior and long-lasting efficacy versus conventional photodynamic therapy. No adverse events were reported, but ablative fractional laser-assisted drug delivery implies risks of systemic drug absorption, especially when performed over large skin areas. Fractional laser-assisted drug delivery is beneficial in enhancing preclinical and clinical outcomes for certain skin conditions. Copyright © 2015 American Academy of Dermatology, Inc. Published by Elsevier Inc. All rights reserved.

  15. Ambient Profiling of Phenolic Content in Tea Infusions by Matrix-Assisted Ionization in Vacuum

    NASA Astrophysics Data System (ADS)

    Cody, Robert B.

    2018-05-01

    Matrix-assisted ionization in vacuum (MAIV) was used to analyze the polyphenol content of ten different tea infusions. Nine different Camellia sinensis infusions were analyzed including three green teas, two black teas, two oolong teas, jasmine tea, and white tea. An infusion of rooibos (Aspalathus linearis) tea was also analyzed. Each freshly brewed tea was diluted 1:1 with methanol, and 100 ppm of phenolphthalein was added as an internal standard. An excess of 3-nitrobenzonitrile (NBN) was added to each vial, and the solution containing NBN crystals was analyzed by aspiration directly into the mass spectrometer sampling orifice. A working curve constructed for dilutions of catechin with phenolphthalein internal standard showed good linearity for five replicates of each concentration. The measured relative abundances of flavonoid polyphenols in each tea were in good agreement with previously reported values. Polyphenol content in tea infusions varied from 19.2 to 108.6 mg 100 mL-1. In addition to the expected catechin flavonoids, abundant quinic acid and gallic acid was detected in the C. sinensis infusions. Characteristic A. linearis flavonoids were detected in the rooibos tea.

  16. Abdominal wall integrity after open abdomen: long-term results of vacuum-assisted wound closure and mesh-mediated fascial traction (VAWCM).

    PubMed

    Willms, A; Schaaf, S; Schwab, R; Richardsen, I; Bieler, D; Wagner, B; Güsgen, C

    2016-12-01

    The open abdomen has become a standard technique in the management of critically ill patients undergoing surgery for severe intra-abdominal conditions. Negative pressure and mesh-mediated fascial traction are commonly used and achieve low fistula rates and high fascial closure rates. In this study, long-term results of a standardised treatment approach are presented. Fifty-five patients who underwent OA management for different indications at our institution from 2006 to 2013 were enrolled. All patients were treated under a standardised algorithm that uses a combination of vacuum-assisted wound closure and mesh-mediated fascial traction. Structured follow-up assessments were offered to patients and included a medical history, a clinical examination and abdominal ultrasonography. The data obtained were statistically analysed. The fascial closure rate was 74 % in an intention-to-treat analysis and 89 % in a per-protocol analysis. The fistula rate was 1.8 %. Thirty-four patients attended follow-up. The median follow-up was 46 months (range 12-88 months). Incisional hernias developed in 35 %. Patients with hernias needed more operative procedures (10.3 vs 3.4, p = 0.03) than patients without hernia formation. A Patient Observer Scar Assessment Scale (POSAS) of 31.1 was calculated. Patients with symptomatic hernias (NAS of 2-10) had a significantly lower mean POSAS score (p = 0.04). Vacuum-assisted wound closure and mesh-mediated fascial traction (VAWCM) seem to result in low complication rates and high fascial closure rates. Abdominal wall reconstruction, which is a challenging and complex procedure and causes considerable patient discomfort, can thus be avoided in the majority of cases. Available results are based on studies involving only a small number of cases. Multi-centre studies and registry-based data are therefore needed to validate these findings.

  17. Time-reversal Techniques in Ultrasound-assisted Convection-enhanced Drug Delivery to the Brain: Technology Development and In Vivo Evaluation

    PubMed Central

    Lewis, George K.; Guarino, Sabrina; Gandhi, Gaurav; Filinger, Laurent; Lewis, George K.; Olbricht, Willam L.; Sarvazyan, Armen

    2011-01-01

    We describe a drug delivery method that combines Time-Reversal Acoustics (TRA) with Convection-Enhanced Delivery (CED) to improve the delivery of therapeutics to the interstitium of the brain. The Ultrasound-assisted CED approach (UCED) circumvents the blood-brain barrier by infusing compounds through a cannula that is inserted into the brain while simultaneously delivering ultrasound to improve the penetration of pharmaceuticals. CED without ultrasound-assistance has been used to treat a variety of neural disorders, including glioblastoma multiforme, a malignancy that presents a very poor prognosis for patients. We describe a novel system that is used to infuse fluids into the brain parenchyma while simultaneously exposing the tissue to safe levels of 1-MHz, low intensity, ultrasound energy. The system includes a combined infusion needle-hydrophone, a 10-channel ultralow-output impedance amplifier, a broad-band ultrasound resonator, and MatLab®-based TRA control and user-interface. TRA allows easy coupling of ultrasound therapy through the skull without complex phase-correction and array design. The smart targeting UCED system has been tested in vivo and results show it provides 1.5-mm spatial resolution for UCED and improves tracer distribution in the brain over CED alone. PMID:21881622

  18. Fabrication of high specificity hollow mesoporous silica nanoparticles assisted by Eudragit for targeted drug delivery.

    PubMed

    She, Xiaodong; Chen, Lijue; Velleman, Leonora; Li, Chengpeng; Zhu, Haijin; He, Canzhong; Wang, Tao; Shigdar, Sarah; Duan, Wei; Kong, Lingxue

    2015-05-01

    Hollow mesoporous silica nanoparticles (HMSNs) are one of the most promising carriers for effective drug delivery due to their large surface area, high volume for drug loading and excellent biocompatibility. However, the non-ionic surfactant templated HMSNs often have a broad size distribution and a defective mesoporous structure because of the difficulties involved in controlling the formation and organization of micelles for the growth of silica framework. In this paper, a novel "Eudragit assisted" strategy has been developed to fabricate HMSNs by utilising the Eudragit nanoparticles as cores and to assist in the self-assembly of micelle organisation. Highly dispersed mesoporous silica spheres with intact hollow interiors and through pores on the shell were fabricated. The HMSNs have a high surface area (670 m(2)/g), small diameter (120 nm) and uniform pore size (2.5 nm) that facilitated the effective encapsulation of 5-fluorouracil within HMSNs, achieving a high loading capacity of 194.5 mg(5-FU)/g(HMSNs). The HMSNs were non-cytotoxic to colorectal cancer cells SW480 and can be bioconjugated with Epidermal Growth Factor (EGF) for efficient and specific cell internalization. The high specificity and excellent targeting performance of EGF grafted HMSNs have demonstrated that they can become potential intracellular drug delivery vehicles for colorectal cancers via EGF-EGFR interaction. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Reducing high-order perineal laceration during operative vaginal delivery.

    PubMed

    Hirsch, Emmet; Haney, Elaine I; Gordon, Trent E J; Silver, Richard K

    2008-06-01

    This study was undertaken to assess the impact of a focused intervention on reducing high-order (third and fourth degree) perineal lacerations during operative vaginal delivery. The following recommendations for clinical management were promulgated by departmental lectures, distribution of pertinent articles and manuals, training of physicians, and prominent display of an instructional poster: (1) increased utilization of vacuum extraction over forceps delivery; (2) conversion of occiput posterior to anterior positions before delivery; (3) performance of mediolateral episiotomy if episiotomy was deemed necessary; (4) flexion of the fetal head and maintenance of axis traction; (5) early disarticulation of forceps; and (6) reduced maternal effort at expulsion. Peer comparison was encouraged by provision of individual and departmental statistics. Clinical data were extracted from the labor and delivery database and the medical record. One hundred fifteen operative vaginal deliveries occurred in the 3 quarters preceding the intervention, compared with 100 afterward (P = .36). High-order laceration with operative vaginal delivery declined from 41% to 26% (P = .02), coincident with increased use of vacuum (16% vs 29% of operative vaginal deliveries, P = .02); fewer high-order lacerations after episiotomy (63% vs 22%, P = .003); a nonsignificant reduction in performance of episiotomy (30% vs 23%, P = .22); and a nonsignificant increase in mediolateral episiotomy (14% vs 30% of episiotomies, P = .19). Introduction of formal practice recommendations and performance review was associated with diminished high-order perineal injury with operative vaginal delivery.

  20. Indications for Emergency Intervention, Mode of Delivery, and the Childbirth Experience.

    PubMed

    Handelzalts, Jonathan E; Waldman Peyser, Avigail; Krissi, Haim; Levy, Sigal; Wiznitzer, Arnon; Peled, Yoav

    2017-01-01

    Although the impact of emergency procedures on the childbirth experience has been studied extensively, a possible association of childbirth experience with indications for emergency interventions has not been reported. To compare the impacts on childbirth experience of 'planned' delivery (elective cesarean section and vaginal delivery) versus 'unplanned' delivery (vacuum extraction or emergency cesarean section); the intervention itself (vacuum extraction versus emergency cesarean section); and indications for intervention (arrest of labor versus risk to the mother or fetus). A total of 469 women, up to 72 hours post-partum, in the maternity ward of one tertiary health care institute completed the Subjective Childbirth Experience Questionnaire (score: 0-4, a higher score indicated a more negative experience) and a Personal Information Questionnaire. Intra-partum information was retrieved from the medical records. One-way analysis of variance and two-way analysis of variance, followed by analysis of covariance, to test the unique contribution of variables, were used to examine differences between groups in outcome. Tukey's Post-Hoc analysis was used when appropriate. Planned delivery, either vaginal or elective cesarean section, was associated with a more positive experience than unplanned delivery, either vacuum or emergency cesarean section (mean respective Subjective Childbirth Experience scores: 1.58 and 1.49 vs. 2.02 and 2.07, P <0.01). The difference in mean Subjective Childbirth Experience scores following elective cesarean section and vaginal delivery was not significant; nor was the difference following vacuum extraction and emergency cesarean section. Interventions due to immediate risk to mother or fetus resulted in a more positive birth experience than interventions due to arrest of labor (Subjective Childbirth Experience: 1.9 vs. 2.2, P <0.01). Compared to planned interventions, unplanned interventions were shown to be associated with a more negative

  1. [Application research of presacral space drainage tube combined with subcutaneous vacuum pressure suction in the laparoscopic-assisted abdominoperineal resection].

    PubMed

    Chen, Liqi; Zeng, Changqing; Chi, Liangjie; Huang, Liangxiang; Li, Jiandang

    2017-08-25

    To study the management for the perineal incision after laparoscopic-assisted abdominoperineal resection for rectal cancer. Clinical data of 87 patients undergoing laparoscopic Miles operation for lower rectal cancer from June 2009 to February 2014 were collected and studied. Presacral space drainage group: presacral space drainage tube was applied in 42 patients. Combined drainage group: presacral space drainage tube combined with subcutaneous vacuum pressure suction was applied in 45 cases. In combined drainage group, except the presacral drainage tube, another drainage tube was placed subcutaneously and connected to a negative pressure ball, which was fixed on the lateral anterior of perineal wound by the further incision and drainage. After subcutaneous tube was placed for 2 weeks, as drainage fluid was limpid and <15 ml/d for 3 days, meanwhile no obvious pelvic fluid was detected by ultrasound, and the wound healed quite well without redness and edema, then the subcutaneous tube with the negative pressure ball could be removed. There were 51 males and 36 females with the mean age of 26-78(56.9±10.8) years old. The laparoscopic Miles operation was successfully completed in all the cases without death and complications. The drainage tube was placed for 4-13(8.0±2.5) days in presacral space drainage group, and for 4-14(6.7±2.4) days in combined drainage group. The subcutaneous tube was placed for 14-24(15.8±3.0) days. The primary healing rate of perineal wound in presacral space drainage group and combined drainage group was 66.7%(28/42) and 91.1%(41/45) respectively, while the perineal wound infection rate was 21.4%(9/42) and 4.4%(2/45) respectively, whose differences between two groups were both significant (χ 2 =7.911, P=0.005 and χ 2 =5.674, P=0.017). Presacral space drainage tube combined with subcutaneous vacuum pressure suction in laparoscopic-assisted abdominoperineal resection for rectal cancer has better efficacy and lower infection rate for

  2. Sonographically-guided vacuum-assisted biopsy with digital mammography-guided skin marking of suspicious breast microcalcifications: comparison of outcomes with stereotactic biopsy in Asian women.

    PubMed

    Hahn, Soo Yeon; Shin, Jung Hee; Han, Boo-Kyung; Ko, Eun Young

    2011-02-01

    Management of suspicious microcalcifications in very thin breasts is problematic. To evaluate whether sonographically-guided vacuum-assisted biopsy (USVAB) with digital mammography-guided skin marking (DM) for the diagnosis of breast microcalcifications is comparable to stereotactic-guided vacuum-assisted biopsy (SVAB) in Asian women with thin breasts. Retrospective review was performed for 263 consecutive suspicious microcalcification lesions in 261 women who underwent USVAB with DM or SVAB using a prone table between January 2004 and December 2007. SVAB was performed for 190 lesions and USVAB for 73 lesions. Biopsy results were correlated with surgical pathology or followed up for at least 12 months. The diagnostic outcomes of SVAB and USVAB to diagnose microcalcifications were compared. Of 263 lesions, 104 (40%) underwent surgery and 159 (60%) were followed up. SVAB and USVAB groups showed similar final categories or the extent of microcalcifications. US visible lesions were 57 (78%) of 73 at USVAB and 14 (10%) of 140 at SVAB. Of 57 US visible lesions at USVAB, 29 (51%) were not found in initial US but were detectable with the help of DM. Specimen radiographs were negative in 2.1% of lesions at SVAB and in 4.1% at USVAB (p=0.4008). The under-estimation rate and false-negative rate were similar in SVAB and USVAB. US with DM facilitates US visibility of microcalcifications. USVAB with DM can produce acceptable biopsy results, as can SVAB, to diagnose breast microcalcifications in patients with thin breasts.

  3. Wireless Integrated Microelectronic Vacuum Sensor System

    NASA Technical Reports Server (NTRS)

    Krug, Eric; Philpot, Brian; Trott, Aaron; Lawrence, Shaun

    2013-01-01

    NASA Stennis Space Center's (SSC's) large rocket engine test facility requires the use of liquid propellants, including the use of cryogenic fluids like liquid hydrogen as fuel, and liquid oxygen as an oxidizer (gases which have been liquefied at very low temperatures). These fluids require special handling, storage, and transfer technology. The biggest problem associated with transferring cryogenic liquids is product loss due to heat transfer. Vacuum jacketed piping is specifically designed to maintain high thermal efficiency so that cryogenic liquids can be transferred with minimal heat transfer. A vacuum jacketed pipe is essentially two pipes in one. There is an inner carrier pipe, in which the cryogenic liquid is actually transferred, and an outer jacket pipe that supports and seals the vacuum insulation, forming the "vacuum jacket." The integrity of the vacuum jacketed transmission lines that transfer the cryogenic fluid from delivery barges to the test stand must be maintained prior to and during engine testing. To monitor the vacuum in these vacuum jacketed transmission lines, vacuum gauge readings are used. At SSC, vacuum gauge measurements are done on a manual rotation basis with two technicians, each using a handheld instrument. Manual collection of vacuum data is labor intensive and uses valuable personnel time. Additionally, there are times when personnel cannot collect the data in a timely fashion (i.e., when a leak is detected, measurements must be taken more often). Additionally, distribution of this data to all interested parties can be cumbersome. To simplify the vacuum-gauge data collection process, automate the data collection, and decrease the labor costs associated with acquiring these measurements, an automated system that monitors the existing gauges was developed by Invocon, Inc. For this project, Invocon developed a Wireless Integrated Microelectronic Vacuum Sensor System (WIMVSS) that provides the ability to gather vacuum

  4. A vacuum microgripping tool with integrated vibration releasing capability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rong, Weibin; Fan, Zenghua, E-mail: zenghua-fan@163.com; Wang, Lefeng

    2014-08-01

    Pick-and-place of micro-objects is a basic task in various micromanipulation demands. Reliable releasing of micro-objects is usually disturbed due to strong scale effects. This paper focuses on a vacuum micro-gripper with vibration releasing functionality, which was designed and assembled for reliable micromanipulation tasks. Accordingly, a vibration releasing strategy of implementing a piezoelectric actuator on the vacuum microgripping tool is presented to address the releasing problem. The releasing mechanism was illustrated using a dynamic micro contact model. This model was developed via theoretical analysis, simulations and pull-off force measurement using atomic force microscopy. Micromanipulation experiments were conducted to verify the performancemore » of the vacuum micro-gripper. The results show that, with the assistance of the vibration releasing, the vacuum microgripping tool can achieve reliable release of micro-objects. A releasing location accuracy of 4.5±0.5 μm and a successful releasing rate of around 100% (which is based on 110 trials) were achieved for manipulating polystyrene microspheres with radius of 35–100 μm.« less

  5. Chemical changes exhibited by latent fingerprints after exposure to vacuum conditions.

    PubMed

    Bright, Nicholas J; Willson, Terry R; Driscoll, Daniel J; Reddy, Subrayal M; Webb, Roger P; Bleay, Stephen; Ward, Neil I; Kirkby, Karen J; Bailey, Melanie J

    2013-07-10

    The effect of vacuum exposure on latent fingerprint chemistry has been evaluated. Fingerprints were analysed using a quartz crystal microbalance to measure changes in mass, gas chromatography mass spectrometry to measure changes in lipid composition and attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) to determine changes in the content of water, fatty acids and their esters after exposure to vacuum. The results are compared with samples aged under ambient conditions. It was found that fingerprints lose around 26% of their mass when exposed to vacuum conditions, equivalent to around 5 weeks ageing under ambient conditions. Further exposure to vacuum causes a significant reduction in the lipid composition of a fingerprint, in particular with the loss of tetradecanoic and pentadecanoic acid, that was not observed in ambient aged samples. There are therefore implications for sequence in which fingerprint development procedures (for example vacuum metal deposition) are carried out, as well as the use of vacuum based methods such as secondary ion mass spectrometry (SIMS) and matrix-assisted laser desorption ionisation (MALDI) in the study of fingerprint chemistry. Copyright © 2013. Published by Elsevier Ireland Ltd.

  6. Initial Experience with a Wireless Ultrasound-Guided Vacuum-Assisted Breast Biopsy Device

    PubMed Central

    Choi, E-Ryung; Han, Boo-Kyung; Ko, Eun Sook; Ko, Eun Young; Choi, Ji Soo; Cho, Eun Yoon; Nam, Seok Jin

    2015-01-01

    Objective To determine the imaging characteristic of frequent target lesions of wireless ultrasound (US)-guided, vacuum-assisted breast biopsy (Wi-UVAB) and to evaluate diagnostic yield, accuracy and complication of the device in indeterminate breast lesions. Materials and Methods From March 2013 to October 2014, 114 women (age range, 29–76 years; mean age, 50.0 years) underwent Wi-UVAB using a 13-gauge needle (Mammotome Elite®; Devicor Medical Products, Cincinnati, OH, USA). In 103 lesions of 96 women with surgical (n = 81) or follow-up (n = 22) data, complications, biopsy procedure, imaging findings of biopsy targets and histologic results were reviewed. Results Mean number of biopsy cores was 10 (range 4–25). Nine patients developed moderate bleeding. All lesions were suspicious on US, and included non-mass lesions (67.0%) and mass lesions (33.0%). Visible calcifications on US were evident in 57.3% of the target lesions. Most of the lesions (93.2%) were nonpalpable. Sixty-six (64.1%) were malignant [ductal carcinoma in situ (DCIS) rate, 61%] and 12 were high-risk lesions (11.7%). Histologic underestimation was identified in 11 of 40 (27.5%). DCIS cases and in 3 of 9 (33.3%) high-risk lesions necessitating surgery. There was no false-negative case. Conclusion Wi-UVAB is very handy and advantageous for US-unapparent non-mass lesions to diagnose DCIS, especially for calcification cases. Histologic underestimation is unavoidable; still, Wi-UVAB is safe and accurate to diagnose a malignancy. PMID:26630136

  7. Bilirubin Nanoparticle-Assisted Delivery of a Small Molecule-Drug Conjugate for Targeted Cancer Therapy.

    PubMed

    Lee, Soyoung; Lee, Yonghyun; Kim, Hyungjun; Lee, Dong Yun; Jon, Sangyong

    2018-06-11

    Despite growing interest in targeted cancer therapy with small molecule drug conjugates (SMDCs), the short half-life of these conjugates in blood associated with their small size has limited their efficacy in cancer therapy. In this report, we propose a new approach for improving the antitumor efficacy of SMDCs based on nanoparticle-assisted delivery. Ideally, a nanoparticle-based delivery vehicle would prolong the half-life of an SMDC in blood and then release it in response to stimuli in the tumor microenvironment (TME). In this study, PEGylated bilirubin-based nanoparticles (BRNPs) were chosen as an appropriate delivery carrier because of their ability to release drugs in response to TME-associated reactive oxygen species (ROS) through rapid particle disruption. As a model SMDC, ACUPA-SN38 was synthesized by linking the prostate-specific membrane antigen (PSMA)-targeting ligand, ACUPA, to the chemotherapeutic agent, SN38. ACUPA-SN38 was loaded into BRNPs using a film-formation and rehydration method. The resulting ACUPA-SN38@BRNPs exhibited ROS-mediated particle disruption and rapid release of the SMDC, resulting in greater cytotoxicity toward PSMA-overexpressing prostate cancer cells (LNCaP) than toward ROS-unresponsive ACUPA-SN38@Liposomes. In a pharmacokinetic study, the circulation time of ACUPA-SN38@BRNPs in blood was prolonged by approximately 2-fold compared with that of the SMDC-based micellar nanoparticles. Finally, ACUPA-SN38@BRNPs showed greater antitumor efficacy in a PSMA-overexpressing human prostate xenograft tumor model than SN38@BRNPs or the SMDC alone. Collectively, these findings suggest that BRNPs are a viable delivery carrier option for various cancer-targeting SMDCs that suffer from short circulation half-life and limited therapeutic efficacy.

  8. Control of Postpartum Hemorrhage Using Vacuum-Induced Uterine Tamponade.

    PubMed

    Purwosunu, Yuditiya; Sarkoen, Widyastuti; Arulkumaran, Sabaratnam; Segnitz, Jan

    2016-07-01

    Postpartum hemorrhage is the leading cause of maternal mortality worldwide. Vacuum-induced uterine tamponade is a possible alternative approach to balloon tamponade systems for the treatment of postpartum hemorrhage resulting from atony. In a prospective proof-of-concept investigation of 10 women with vaginal deliveries in a hospital setting who failed first-line therapies for postpartum hemorrhage, tamponade was used. Vacuum-induced uterine tamponade was created through a device inserted transvaginally into the uterine cavity. An occlusion balloon built into the device shaft was inflated at the level of the external cervical os to create a uterine seal. Negative pressure was created by attaching a self-contained, mobile, electrically powered, pressure-regulated vacuum pump with a sterile graduated canister. In all 10 cases, the suction created an immediate seal at the cervical os, 50-250 mL of residual blood was evacuated from the uterine cavity, the uterus collapsed and regained tone within minutes, and hemorrhaging was controlled. The device remained in place for a minimum of 1 hour and up to 6.5 hours in one case while vaginal and perineal lacerations were easily repaired. This preliminary investigation suggests that a device designed to create vacuum-induced uterine tamponade may be a reasonable alternative to other devices used to treat atonic postpartum hemorrhage.

  9. Molecular Weight Cut-Off and Structural Analysis of Vacuum-Assisted Titania Membranes for Water Processing

    PubMed Central

    Abd Jalil, Siti Nurehan; Wang, David K.; Yacou, Christelle; Motuzas, Julius; Smart, Simon; Diniz da Costa, João C.

    2016-01-01

    This work investigates the structural formation and analyses of titania membranes (TM) prepared using different vacuum exposure times for molecular weight (MW) cut-off performance and oil/water separation. Titania membranes were synthesized via a sol-gel method and coated on macroporous alumina tubes followed by exposure to a vacuum between 30 and 1200 s and then calcined at 400 °C. X-ray diffraction and nitrogen adsorption analyses showed that the crystallite size and particle size of titania increased as a function of vacuum time. All the TM membranes were mesoporous with an average pore diameter of ~3.6 nm with an anatase crystal morphology. Water, glucose, sucrose, and polyvinylpyrrolidone with 40 and 360 kDa (PVP-40 kDa and PVP-360 kDa) were used as feed solutions for MW cut-off and hexadecane solution for oil filtration investigation. The TM membranes were not able to separate glucose and sucrose, thus indicating the membrane pore sizes are larger than the kinetic diameter of sucrose of 0.9 nm, irrespective of vacuum exposure time. They also showed only moderate rejection (20%) of the smaller PVP-40 kDa, however, all the membranes were able to obtain an excellent rejection of near 100% for the larger PVP-360 kDa molecule. Furthermore, the TM membranes were tested for the separation of oil emulsions with a high concentration of oil (3000 ppm), reaching high oil rejections of more than 90% of oil. In general, the water fluxes increased with the vacuum exposure time indicating a pore structural tailoring effect. It is therefore proposed that a mechanism of pore size tailoring was formed by an interconnected network of Ti–O–Ti nanoparticles with inter-particle voids, which increased as TiO2 nanoparticle size increased as a function of vacuum exposure time, and thus reduced the water transport resistance through the TM membranes. PMID:28774057

  10. Indian Vacuum Society: The Indian Vacuum Society

    NASA Astrophysics Data System (ADS)

    Saha, T. K.

    2008-03-01

    The Indian Vacuum Society (IVS) was established in 1970. It has over 800 members including many from Industry and R & D Institutions spread throughout India. The society has an active chapter at Kolkata. The society was formed with the main aim to promote, encourage and develop the growth of Vacuum Science, Techniques and Applications in India. In order to achieve this aim it has conducted a number of short term courses at graduate and technician levels on vacuum science and technology on topics ranging from low vacuum to ultrahigh vacuum So far it has conducted 39 such courses at different parts of the country and imparted training to more than 1200 persons in the field. Some of these courses were in-plant training courses conducted on the premises of the establishment and designed to take care of the special needs of the establishment. IVS also regularly conducts national and international seminars and symposia on vacuum science and technology with special emphasis on some theme related to applications of vacuum. A large number of delegates from all over India take part in the deliberations of such seminars and symposia and present their work. IVS also arranges technical visits to different industries and research institutes. The society also helped in the UNESCO sponsored post-graduate level courses in vacuum science, technology and applications conducted by Mumbai University. The society has also designed a certificate and diploma course for graduate level students studying vacuum science and technology and has submitted a syllabus to the academic council of the University of Mumbai for their approval, we hope that some colleges affiliated to the university will start this course from the coming academic year. IVS extended its support in standardizing many of the vacuum instruments and played a vital role in helping to set up a Regional Testing Centre along with BARC. As part of the development of vacuum education, the society arranges the participation of

  11. Vacuum-assisted decellularization: an accelerated protocol to generate tissue-engineered human tracheal scaffolds.

    PubMed

    Butler, Colin R; Hynds, Robert E; Crowley, Claire; Gowers, Kate H C; Partington, Leanne; Hamilton, Nicholas J; Carvalho, Carla; Platé, Manuela; Samuel, Edward R; Burns, Alan J; Urbani, Luca; Birchall, Martin A; Lowdell, Mark W; De Coppi, Paolo; Janes, Sam M

    2017-04-01

    Patients with large tracheal lesions unsuitable for conventional endoscopic or open operations may require a tracheal replacement but there is no present consensus of how this may be achieved. Tissue engineering using decellularized or synthetic tracheal scaffolds offers a new avenue for airway reconstruction. Decellularized human donor tracheal scaffolds have been applied in compassionate-use clinical cases but naturally derived extracellular matrix (ECM) scaffolds demand lengthy preparation times. Here, we compare a clinically applied detergent-enzymatic method (DEM) with an accelerated vacuum-assisted decellularization (VAD) protocol. We examined the histological appearance, DNA content and extracellular matrix composition of human donor tracheae decellularized using these techniques. Further, we performed scanning electron microscopy (SEM) and biomechanical testing to analyze decellularization performance. To assess the biocompatibility of scaffolds generated using VAD, we seeded scaffolds with primary human airway epithelial cells in vitro and performed in vivo chick chorioallantoic membrane (CAM) and subcutaneous implantation assays. Both DEM and VAD protocols produced well-decellularized tracheal scaffolds with no adverse mechanical effects and scaffolds retained the capacity for in vitro and in vivo cellular integration. We conclude that the substantial reduction in time required to produce scaffolds using VAD compared to DEM (approximately 9 days vs. 3-8 weeks) does not compromise the quality of human tracheal scaffold generated. These findings might inform clinical decellularization techniques as VAD offers accelerated scaffold production and reduces the associated costs. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  12. Systemic delivery of siRNA with cationic lipid assisted PEG-PLA nanoparticles for cancer therapy.

    PubMed

    Yang, Xian-Zhu; Dou, Shuang; Sun, Tian-Meng; Mao, Cheng-Qiong; Wang, Hong-Xia; Wang, Jun

    2011-12-10

    Delivery of small interfering RNA (siRNA) has been one of the major hurdles for the application of RNA interference in therapeutics. Here, we describe a cationic lipid assisted polymeric nanoparticle system with stealthy property for efficient siRNA encapsulation and delivery, which was fabricated with poly(ethylene glycol)-b-poly(d,l-lactide), siRNA and a cationic lipid, using a double emulsion-solvent evaporation technique. By incorporation of the cationic lipid, the encapsulation efficiency of siRNA into the nanoparticles could be above 90% and the siRNA loading weight ratio was up to 4.47%, while the diameter of the nanoparticles was around 170 to 200nm. The siRNA retained its integrity within the nanoparticles, which were effectively internalized by cancer cells and escaped from the endosome, resulting in significant gene knockdown. This effect was demonstrated by significant down-regulation of luciferase expression in HepG2-luciferase cells which stably express luciferase, and suppression of polo-like kinase 1 (Plk1) expression in HepG2 cells, following delivery of specific siRNAs by the nanoparticles. Furthermore, the nanoparticles carrying siRNA targeting the Plk1 gene were found to induce remarkable apoptosis in both HepG2 and MDA-MB-435s cancer cells. Systemic delivery of specific siRNA by nanoparticles significantly inhibited luciferase expression in an orthotopic murine liver cancer model and suppressed tumor growth in a MDA-MB-435s murine xenograft model, suggesting its therapeutic promise in disease treatment. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Impact of expanded-duty assistants on cost and productivity in dental care delivery.

    PubMed Central

    Lipscomb, J; Scheffler, R M

    1975-01-01

    Data from an experimental dental program are used to develop a linear programming model of dental care delivery that the authors use to examine the economic implications of introducing expanded-duty dental assistants (EDDA's) in three types of dental practices. The authors examine the changes in productivity and profitability that result from hiring one or more EDDAs and conclude that a dentist in solo practice can more than double his net revenue by hiring one EDDA but will not increase his productivity further by hiring additional EDDAs. Two- and three-dentist groups also can increase revenue by hiring EDDAs, but, beyond a certain point, an inverse relationship exists between the number of auxiliaries hired and net revenue generated. PMID:812848

  14. Effects of quadratic coupling and squeezed vacuum injection in an optomechanical cavity assisted with a Bose-Einstein condensate

    NASA Astrophysics Data System (ADS)

    Dalafi, A.; Naderi, M. H.; Motazedifard, Ali

    2018-04-01

    We investigate theoretically a hybrid system consisting of a Bose-Einstein condensate (BEC) trapped inside a laser-driven membrane-in-the-middle optomechanical cavity assisted with squeezed vacuum injection whose moving membrane interacts both linearly and quadratically with the radiation pressure of the cavity. It is shown that such a hybrid system is very suitable for generating strong quadrature squeezing in the mechanical mode of the membrane and the Bogoliubov mode of the BEC in the unresolved sideband regime. More interestingly, by choosing a suitable sign for the quadratic optomechanical coupling (QOC), one can achieve a very high degree of squeezing in the mechanical mode and a strong entanglement between the mechanical and atomic modes without the necessity of using squeezed light injection. Furthermore, the QOC changes the effective oscillation frequencies of both the mechanical and the atomic modes and affects their relaxation times. It can also make the system switch from optical bistability to tristability.

  15. The optimal mode of delivery for the haemophilia carrier expecting an affected infant is vaginal delivery.

    PubMed

    Ljung, R

    2010-05-01

    The optimal mode of delivery of a haemophilia carrier expecting a child is still a matter of uncertainty and debate. The aim of this commentary/review is to suggest that normal vaginal delivery should be the recommended mode of delivery for the majority of carriers, based on review of studies on obstetric aspects of haemophilia. About 2.0-4.0% of all haemophilia boys born in countries with a good standard of health care will suffer from ICH during the neonatal period. This is an average figure including all modes of delivery and regardless of whether the carrier status of the mother or the haemophilia status of the foetus was known or not at the time of delivery. On the basis of current literature, one may conclude that the risk of serious bleeding in the neonate affected with haemophilia is small in conjunction with normal vaginal delivery. It should be possible to further reduce the low frequency of complications if appropriate precautions are taken when planning the delivery in pregnant woman with known carrier status, if the sex of the foetus is known and, even more, when the haemophilia status of the foetus is known. Instrumental delivery such as use of vacuum extraction and foetal scalp monitors must be avoided at delivery of carriers.

  16. 75 FR 60588 - Immediate Disaster Assistance Program

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-01

    ... Hedgespeth, Director of Financial Assistance, U.S. Small Business Administration, 409 3rd Street, SW., 8th floor, Washington, DC 20416. Hand Delivery/Courier: Grady Hedgespeth, Director of Financial Assistance... Hand Delivery and you must address the comment to the attention of Grady Hedgespeth, Director of...

  17. [Learning curve of vacuum extraction in residency: a preliminary study].

    PubMed

    Velemir, L; Vendittelli, F; Bonnefoy, C; Accoceberry, M; Savary, D; Gallot, D

    2009-09-01

    The aim of this study was to assess the lurning curve of young residents for vacuum extraction. All vacuum extractions performed in our department by five residents (< or =5th semester) during a study period of nine months were systematically supervised by a senior who fulfilled an assessment questionnaire from which was calculated a score reflecting the quality of the extraction. Fifty-four vacuum extractions were assessed with a mean of 10.8+/-2.9 (range, 10-13) procedures by resident. We compared the group including the six first procedures performed by each resident (group 1, n = 30) with the group including the following procedures (group 2, n = 24). We observed in the group 2 compared to the group 1, a significant improvement of the scores mean (12.3+/-5.4 vs 8.4+/-6.2, p = 0.016) and a significant reduction of the need for manual assistance by the senior (12.5% vs 40%, p = 0.034). We report a method for the learning and assessment of vacuum extraction feasible at "the bed" of the patient. This approach allows to observe a significant progression of the resident for the technique of vacuum extraction on a dozen of procedures.

  18. [Surgical methods for delivery in modern obstetrics and their influence on maternal and infant health].

    PubMed

    Kokhanevych, Ie V; Mitsoda, R M; Konoplianko, T V; Konoplianko, V V

    2000-03-01

    The article addresses issues of comparative characterization of deliveries involving surgery and impact thereof on the health of the mother and her child. Risk factors are identified that the mother and her child run in sectio cesarea, in application of obstetrical forceps, and in vacuum-extraction of the fetus. Cesarean section was found out to be the most acceptable mode of delivery in origination of organic and functional nervous system involvement in children but the most ill-chosen and unpropitious one in the mother, especially so in those groups at risk for bleeding, septic complications, and genital endometriosis. Among those surgical methods of delivery being the least traumatic to the mother are obstetrical forceps and vacuum-extraction of the fetus.

  19. Ultrasonic Spray Drying vs High Vacuum and Microwaves Technology for Blueberries

    NASA Astrophysics Data System (ADS)

    Candia-Muñoz, N.; Ramirez-Bunster, M.; Vargas-Hernández, Y.; Gaete-Garretón, L.

    Interest in high quality foods: good taste and a high content of nutrients with healthy beneficial effects are increasing. Fruits have good properties but, they are lost because the oxidation process, additionally, for different reasons a 40% of harvested fruit are lost. To conserve the fruit properties an ultrasonic assisted spray dryer was developed and tested, comparing its results with microwave-vacuum drying technology. Results did shown taste, color, smell, particle shape and size distribution better than the conventional one. The antioxidants conservation were quite good except in the anthocyanins, in which the microwave and vacuum technology shown best results.

  20. Optimizing Vacuum Assisted Resin Transfer Moulding (VARTM) Processing Parameters to Improve Part Quality

    NASA Astrophysics Data System (ADS)

    Polowick, Christopher

    The Low Cost Composites (LCC) group at Carleton University is studying out-of-autoclave composite manufacturing processes such as Vacuum Assisted Resin Transfer Moulding (VARTM) and Closed Cavity Bag Moulding (CCBM). These processes are used to produce inexpensive and high performance components for the GeoSurv II, an Unmanned Aerial Vehicle (UAV) being developed at Carleton University. This research has focused on optimizing VARTM processing parameters to reduce the weight and improve the strength and surface finish of GeoSurv II composite components. A simulation was developed to model resin flow through in VARTM infusions and was used to simulate mould filling and resin emptying of the GeoSurv II inverted V-empennage and mission avionics hatch. The resin infusion schemes of these parts were designed to ensure full preform resin saturation, and minimize thickness variations. An experimental study of the effects of the presence of a corner on composite thickness, void content, and strength was conducted. It was found that inside corners result in local increases in thickness and void content due to poor preform compaction. A novel bagging technique was developed to improve corner compaction, and this technique was shown to reduce thickness variability and void content. The strength, void content, and thickness variation were found to be heavily dependent on corner radius, with corner radii greater than 6.4 mm displaying the greatest improvement in performance for the layups considered. The design of the empennage and hatch mould incorporated the results of this study to improve the quality of these components.

  1. Vacuum mechatronics

    NASA Technical Reports Server (NTRS)

    Hackwood, Susan; Belinski, Steven E.; Beni, Gerardo

    1989-01-01

    The discipline of vacuum mechatronics is defined as the design and development of vacuum-compatible computer-controlled mechanisms for manipulating, sensing and testing in a vacuum environment. The importance of vacuum mechatronics is growing with an increased application of vacuum in space studies and in manufacturing for material processing, medicine, microelectronics, emission studies, lyophylisation, freeze drying and packaging. The quickly developing field of vacuum mechatronics will also be the driving force for the realization of an advanced era of totally enclosed clean manufacturing cells. High technology manufacturing has increasingly demanding requirements for precision manipulation, in situ process monitoring and contamination-free environments. To remove the contamination problems associated with human workers, the tendency in many manufacturing processes is to move towards total automation. This will become a requirement in the near future for e.g., microelectronics manufacturing. Automation in ultra-clean manufacturing environments is evolving into the concept of self-contained and fully enclosed manufacturing. A Self Contained Automated Robotic Factory (SCARF) is being developed as a flexible research facility for totally enclosed manufacturing. The construction and successful operation of a SCARF will provide a novel, flexible, self-contained, clean, vacuum manufacturing environment. SCARF also requires very high reliability and intelligent control. The trends in vacuum mechatronics and some of the key research issues are reviewed.

  2. Risk Factors for the Development of Obstetric Anal Sphincter Injuries in Modern Obstetric Practice.

    PubMed

    Ramm, Olga; Woo, Victoria G; Hung, Yun-Yi; Chen, Hsuan-Chih; Ritterman Weintraub, Miranda L

    2018-02-01

    To characterize the rate of obstetric anal sphincter injuries and identify key risk factors of obstetric anal sphincter injuries, including duration of the second stage of labor. This retrospective cohort study included all singleton, term, cephalic vaginal deliveries within Kaiser Permanente Northern California between January 2013 and December 2014 (N=22,741). Incidence of obstetric anal sphincter injuries, defined as third- or fourth-degree perineal lacerations, was the primary outcome. Multiple logistic regression models were conducted to identify obstetric anal sphincter injury risk factors and high-risk subpopulations. The overall incidence rate of obstetric anal sphincter injuries was 4.9% (3.6% of women who delivered spontaneously vs 24.0% of women who had a vacuum-assisted vaginal delivery, P<.001, CI 18.1-22.6%). In bivariate and multivariate analyses, obstetric anal sphincter injury incidence was higher among women with second stage of labor longer than 2 hours, Asian race, nulliparity, vaginal birth after cesarean delivery, episiotomy, and vacuum delivery. Women with a vacuum-assisted vaginal delivery had four times the odds of obstetric anal sphincter injury (adjusted odds ratio [OR] 4.23, 95% CI 3.59-4.98) and those whose second stage of labor lasted at least 180 minutes vs less than 60 minutes had three times the odds of incurring obstetric anal sphincter injury (adjusted OR 3.20, 95% CI 2.62-3.89). Vacuum-assisted vaginal delivery conferred the highest odds of obstetric anal sphincter injury followed by prolonged duration of the second stage of labor, particularly among certain subpopulations. Understanding these risk factors and their complex interactions can inform antepartum and intrapartum decision-making with the goal of reducing obstetric anal sphincter injury incidence.

  3. Dissolving polymeric microneedle arrays for electrically assisted transdermal drug delivery.

    PubMed

    Garland, Martin J; Caffarel-Salvador, Ester; Migalska, Katarzyna; Woolfson, A David; Donnelly, Ryan F

    2012-04-10

    It has recently been proposed that the combination of skin barrier impairment using microneedles (MNs) coupled with iontophoresis (ITP) may broaden the range of drugs suitable for transdermal delivery, as well as enabling the rate of delivery to be achieved with precise electronic control. However, no reports exist on the combination of ITP with in situ drug loaded polymeric MN delivery systems. Furthermore, although a number of studies have highlighted the importance of MN design for transdermal drug delivery enhancement, to date, there has been no systematic investigation of the influence of MN geometry on the performance of polymeric MN arrays which are designed to remain in contact with the skin during the period of drug delivery. As such, for the first time, this study reports on the effect of MN heigth and MN density upon the transdermal delivery of small hydrophilic compounds (theophylline, methylene blue, and fluorescein sodium) across neonatal porcine skin in vitro, with the optimised MN array design evaluated for its potential in the electrically faciliatated delivery of peptide (bovine insulin) and protein (fluorescein isothiocyanate-labelled bovine serum albumin (FTIC-BSA)) macromolecules. The results of the in vitro drug release investigations revealed that the extent of transdermal delivery was dependent upon the design of the MN array employed, whereby an increase in MN height and an increase in MN density led to an increase in the extent of transdermal drug delivery achieved 6h after MN application. Overall, the in vitro permeation studies revealed that the MN design containing 361 MNs/cm(2) of 600 μm height resulted in the greatest extent of transdermal drug delivery. As such, this design was evaluated for its potential in the MN mediated iontophoretic transdermal delivery. Whilst the combination of MN and ITP did not further enhance the extent of small molecular weight solute delivery, the extent of peptide/protein release was significantly

  4. Natural vacuum electronics

    NASA Technical Reports Server (NTRS)

    Leggett, Nickolaus

    1990-01-01

    The ambient natural vacuum of space is proposed as a basis for electron valves. Each valve is an electron controlling structure similiar to a vacuum tube that is operated without a vacuum sustaining envelope. The natural vacuum electron valves discussed offer a viable substitute for solid state devices. The natural vacuum valve is highly resistant to ionizing radiation, system generated electromagnetic pulse, current transients, and direct exposure to space conditions.

  5. VACUUM TRAP

    DOEpatents

    Gordon, H.S.

    1959-09-15

    An improved adsorption vacuum trap for use in vacuum systems was designed. The distinguishing feature is the placement of a plurality of torsionally deformed metallic fins within a vacuum jacket extending from the walls to the central axis so that substantially all gas molecules pass through the jacket will impinge upon the fin surfaces. T fins are heated by direct metallic conduction, thereby ol taining a uniform temperature at the adeorbing surfaces so that essentially all of the condensible impurities from the evacuating gas are removed from the vacuum system.

  6. [Non-invasive assessment of the perfusion of wounds using power Doppler imaging: vacuum assisted closure versus direct wound closure].

    PubMed

    Jungius, K P; Chilla, B K; Labler, L; Teodorovic, N; Marincek, B

    2006-10-01

    The goal of our study was to assess the perfusion in wounds treated by vacuum assisted closure (VAC) compared to primary wound closure. Power Doppler Ultrasound (PDUS) was carried out under standardised conditions in 15 VAC-treated and 10 primarily closed wounds as well as on altogether 25 intraindividual reference areas. All data were sent to a work station for post-processing to determine the perfused area. Statistical data analysis was performed with the Mann-Whitney test. Both VAC-treated wounds and primarily closed wounds showed a significant increase of the perfusion when compared to the intraindividual reference area (p < 0.0001). In VAC-treated wounds, a markedly increased perfusion was measured compared to the wounds closed primarily (p < 0.0001). Perfusion decreased during treatment, but in two VAC-treated wounds, an initial increase of the perfusion was observed. Both these wounds were grossly infected. PDUS allows the quantification of the differences in wound perfusion. This can be helpful in the detection of progressive local wound infections.

  7. Production of cromolyn sodium microparticles for aerosol delivery by supercritical assisted atomization.

    PubMed

    Reverchon, Ernesto; Adami, Renata; Caputo, Giuseppe

    2007-12-21

    The purpose of this study was to produce cromolyn sodium (CS) micrometric particles with controlled particle size (PS) and PS distribution (PSD) suitable for aerosol delivery, using a supercritical fluids-based process. CS was micronized using the supercritical assisted atomization (SAA) technique at different solute concentrations in water and different precipitation temperatures. Two techniques were used to measure PS and PSD of produced particles: scanning electron microscopy image analysis and laser scattering analysis. The 2 techniques were compared to provide a complete description of the powder obtained. High-performance liquid chromatography analysis was used to verify the absence of degradation of CS after micronization; differential scanning calorimetry, thermogravimetric analysis (TGA), and X-ray analysis were performed to study the effect of operative conditions on the crystalline structure and on the water content of SAA micronized particles. The CS particles obtained were spherical, with a volumetric percentage of particles with a diameter ranging between 1 and 5 microm of 50% to 66%. The precipitation temperature had no significant effect on PSD, but high drying temperatures led to product degradation. Increasing the concentration of CS in water solution produced an increase in PS of the micronized particles. TGA showed that the micronized CS had a different hydration state than the untreated CS did. The micronized product was stable after 12 months of storage, and no modifications in structure, morphology, or crystallinity were detected. In conclusion, SAA is an efficient technique for micronization of CS, and stable spherical amorphous particles suitable for aerosol delivery can be produced.

  8. Forceps Delivery Volumes in Teaching and Nonteaching Hospitals: Are Volumes Sufficient for Physicians to Acquire and Maintain Competence?

    PubMed Central

    Kyser, Kathy L.; Lu, Xin; Santillan, Donna; Santillan, Mark; Caughey, Aaron B.; Wilson, Mark C.; Cram, Peter

    2015-01-01

    Purpose The decline in the use of forceps in operative deliveries over the last two decades raises questions about teaching hospitals' ability to provide trainees with adequate experience in the use of forceps. The authors examined: (1) the number of operative deliveries performed in teaching and nonteaching hospitals, and (2) whether teaching hospitals performed a sufficient number of forceps deliveries for physicians to acquire and maintain competence. Method The authors used State Inpatient Data from nine states to identify all women hospitalized for childbirth in 2008. They divided hospitals into three categories: major teaching, minor teaching, and nonteaching. They calculated delivery volumes (total operative, cesarean, vacuum, forceps, two or more methods) for each hospital and compared data across hospital categories. Results The sample included 1,344,305 childbirths in 835 hospitals. The mean cesarean volumes for major teaching, minor teaching, and nonteaching hospitals were 969.8, 757.8, and 406.9. The mean vacuum volumes were 301.0, 304.2, and 190.4, and the mean forceps volumes were 25.2, 15.3, and 8.9. In 2008, 31 hospitals (3.7% of all hospitals) performed no vacuum extractions, and 320 (38.3%) performed no forceps deliveries. In 2008, 13 (23%) major teaching and 44 (44%) minor teaching hospitals performed five or fewer forceps deliveries. Conclusions Low forceps delivery volumes may preclude many trainees from acquiring adequate experience and proficiency. These findings highlighted broader challenges, faced by many specialties, in ensuring that trainees and practicing physicians acquire and maintain competence in infrequently performed, highly technical procedures. PMID:24280847

  9. Determination of transformation products of unsymmetrical dimethylhydrazine in water using vacuum-assisted headspace solid-phase microextraction.

    PubMed

    Orazbayeva, Dina; Kenessov, Bulat; Psillakis, Elefteria; Nassyrova, Dayana; Bektassov, Marat

    2018-06-22

    A new, sensitive and simple method based on vacuum-assisted headspace solid-phase microextraction (Vac-HSSPME) followed by gas chromatography-mass-spectrometry (GC-MS), is proposed for the quantification of rocket fuel unsymmetrical dimethylhydrazine (UDMH) transformation products in water samples. The target transformation products were: pyrazine, 1-methyl-1H-pyrazole, N-nitrosodimethylamine, N,N-dimethylformamide, 1-methyl-1Н-1,2,4-triazole, 1-methyl-imidazole and 1H-pyrazole. For these analytes and within shorter sampling times, Vac-HSSPME yielded detection limits (0.5-100 ng L -1 ) 3-10 times lower than those reported for regular HSSPME. Vac-HSSPME sampling for 30 min at 50 °C yielded the best combination of analyte responses and their standard deviations (<15%). 1-Formyl-2,2-dimethylhydrazine and formamide were discarded because of the poor precision and accuracy when using Vac-HSSPME. The recoveries for the rest of the analytes ranged between 80 and 119%. The modified Mininert valve and Thermogreen septum could be used for automated extraction as it ensured stable analyte signals even after long waiting times (>24 h). Finally, multiple Vac-HSSME proved to be an efficient tool for controlling the matrix effect and quantifying UDMH transformation products. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. ZnO synthesis by high vacuum plasma-assisted chemical vapor deposition using dimethylzinc and atomic oxygen

    NASA Astrophysics Data System (ADS)

    Barnes, Teresa M.; Hand, Steve; Leaf, Jackie; Wolden, Colin A.

    2004-09-01

    Zinc oxide thin films were produced by high vacuum plasma-assisted chemical vapor deposition (HVP-CVD) from dimethylzinc (DMZn) and atomic oxygen. HVP-CVD is differentiated from conventional remote plasma-enhanced CVD in that the operating pressures of the inductively coupled plasma (ICP) source and the deposition chamber are decoupled. Both DMZn and atomic oxygen effuse into the deposition chamber under near collisionless conditions. The deposition rate was measured as a function of DMZn and atomic oxygen flux on glass and silicon substrates. Optical emission spectroscopy and quadrupole mass spectrometry (QMS) were used to provide real time analysis of the ICP source and the deposition chamber. The deposition rate was found to be first order in DMZn pressure and zero order in atomic oxygen density. All films demonstrated excellent transparency and were preferentially orientated along the c-axis. The deposition chemistry occurs exclusively through surface-mediated reactions, since the collisionless transport environment eliminates gas-phase chemistry. QMS analysis revealed that DMZn was almost completely consumed, and desorption of unreacted methyl radicals was greatly accelerated in the presence of atomic oxygen. Negligible zinc was detected in the gas phase, suggesting that Zn was efficiently consumed on the substrate and walls of the reactor.

  11. Vacuum-assisted stereotactic breast biopsy in the diagnosis and management of suspicious microcalcifications

    PubMed Central

    Esen, Gül; Tutar, Burçin; Uras, Cihan; Calay, Zerrin; İnce, Ümit; Tutar, Onur

    2016-01-01

    PURPOSE We aimed to present our biopsy method and retrospectively evaluate the results, upgrade rate, and follow-up findings of stereotactic vacuum-assisted breast biopsy (VABB) procedures performed in our clinic. METHODS Two hundred thirty-four patients with mammographically detected nonpalpable breast lesions underwent VABB using a 9 gauge biopsy probe and prone biopsy table. A total of 195 patients (median age 53 years, range 32–80 years) with 198 microcalcification-only lesions with a follow-up of at least one year were included in the study. The location of the lesion relative to the needle was determined from the postfire images, and unlike the conventional technique, tissue retrieval was predominantly performed from that location, followed by a complete 360° rotation, if needed. RESULTS The median core number was 8.5. Biopsy results revealed 135 benign, 24 atypical, and 39 malignant lesions. The total upgrade rate at surgery was 7.7% (6.1% for ductal carcinomas in situ and 10.5% for atypical lesions). Patients with benign lesions were followed up for a median period of 27.5 months, with no interval change. At the follow-up, scar formation was seen in 23 patients (17%); three of the scars were remarkable for resembling a malignancy. CONCLUSION Our biposy method is fast and practical, and it is easily tolerated by patients without compromising accuracy. Patients with a diagnosis of atypia still need to undergo a diagnostic surgical procedure and those with a malignancy need to undergo curative surgery, even if the lesion is totally excised at biopsy. VABB may leave a scar in the breast tissue, which may resemble a malignancy, albeit rarely. PMID:27306660

  12. Infrared Laser Ablation with Vacuum Capture for Fingermark Sampling

    NASA Astrophysics Data System (ADS)

    Donnarumma, Fabrizio; Camp, Eden E.; Cao, Fan; Murray, Kermit K.

    2017-09-01

    Infrared laser ablation coupled to vacuum capture was employed to collect material from fingermarks deposited on surfaces of different porosity and roughness. Laser ablation at 3 μm was performed in reflection mode with subsequent capture of the ejecta with a filter connected to vacuum. Ablation and capture of standards from fingermarks was demonstrated on glass, plastic, aluminum, and cardboard surfaces. Using matrix assisted laser desorption ionization (MALDI), it was possible to detect caffeine after spiking with amounts as low as 1 ng. MALDI detection of condom lubricants and detection of antibacterial peptides from an antiseptic cream was demonstrated. Detection of explosives from fingermarks left on plastic surfaces as well as from direct deposition on the same surface using gas chromatography mass spectrometry (GC-MS) was shown. [Figure not available: see fulltext.

  13. Infrared Laser Ablation with Vacuum Capture for Fingermark Sampling.

    PubMed

    Donnarumma, Fabrizio; Camp, Eden E; Cao, Fan; Murray, Kermit K

    2017-09-01

    Infrared laser ablation coupled to vacuum capture was employed to collect material from fingermarks deposited on surfaces of different porosity and roughness. Laser ablation at 3 μm was performed in reflection mode with subsequent capture of the ejecta with a filter connected to vacuum. Ablation and capture of standards from fingermarks was demonstrated on glass, plastic, aluminum, and cardboard surfaces. Using matrix assisted laser desorption ionization (MALDI), it was possible to detect caffeine after spiking with amounts as low as 1 ng. MALDI detection of condom lubricants and detection of antibacterial peptides from an antiseptic cream was demonstrated. Detection of explosives from fingermarks left on plastic surfaces as well as from direct deposition on the same surface using gas chromatography mass spectrometry (GC-MS) was shown. Graphical Abstract ᅟ.

  14. Comparison of vacuum and non-vacuum urine tubes for urinary sediment analysis.

    PubMed

    Topcuoglu, Canan; Sezer, Sevilay; Kosem, Arzu; Ercan, Mujgan; Turhan, Turan

    2017-12-01

    Urine collection systems with aspiration system for vacuum tubes are becoming increasingly common for urinalysis, especially for microscopic examination of the urine. In this study, we aimed to examine whether vacuum aspiration of the urine sample has any adverse effect on sediment analysis by comparing results from vacuum and non-vacuum urine tubes. The study included totally 213 urine samples obtained from inpatients and outpatients in our hospital. Urine samples were collected to containers with aspiration system for vacuum tubes. Each sample was aliquoted to both vacuum and non-vacuum urine tubes. Urinary sediment analysis was performed using manual microscope. Results were evaluated using chi-square test. Comparison of the sediment analysis results from vacuum and non-vacuum urine tubes showed that results were highly concordant for erythrocyte, leukocyte and epithelial cells (gamma values 1, 0.997, and 0.994, respectively; p < .001). Results were also concordant for urinary casts, crystals and yeast (kappa values 0.815, 0.945 and 1, respectively; p < .001). The results show that in urinary sediment analysis, vacuum aspiration has no adverse effect on the cellular components except on casts.

  15. Assistive Technology Resource Directory.

    ERIC Educational Resources Information Center

    Council for Exceptional Children, Reston, VA. Center for Special Education Technology.

    This annotated directory of resources is designed to assist in locating key organizations, agencies, and projects that are involved in the delivery of assistive technology services at the national, state, and local levels. Resources described include three federal agencies, nine national associations, five rehabilitation engineering centers, four…

  16. Ultrasound-guided cable-free 13-gauge vacuum-assisted biopsy of non-mass breast lesions

    PubMed Central

    Seo, Jiwoon; Jang, Mijung; Yun, Bo La; Lee, Soo Hyun; Kim, Eun-Kyu; Kang, Eunyoung; Park, So Yeon; Moon, Woo Kyung; Choi, Hye Young; Kim, Bohyoung

    2017-01-01

    Purpose To compare the outcomes of ultrasound-guided core biopsy for non-mass breast lesions by the novel 13-gauge cable-free vacuum-assisted biopsy (VAB) and by the conventional 14-gauge semi-automated core needle biopsy (CCNB). Materials and methods Our institutional review board approved this prospective study, and all patients provided written informed consent. Among 1840 ultrasound-guided percutaneous biopsies performed from August 2013 to December 2014, 145 non-mass breast lesions with suspicious microcalcifications on mammography or corresponding magnetic resonance imaging finding were subjected to 13-gauge VAB or 14-gauge CCNB. We evaluated the technical success rates, average specimen numbers, and tissue sampling time. We also compared the results of percutaneous biopsy and final surgical pathologic diagnosis to analyze the rates of diagnostic upgrade or downgrade. Results Ultrasound-guided VAB successfully targeted and sampled all lesions, whereas CCNB failed to demonstrate calcification in four (10.3%) breast lesions with microcalcification on specimen mammography. The mean sampling time were 238.6 and 170.6 seconds for VAB and CCNB, respectively. No major complications were observed with either method. Ductal carcinoma in situ (DCIS) and atypical ductal hyperplasia (ADH) lesions were more frequently upgraded after CCNB (8/23 and 3/5, respectively) than after VAB (2/26 and 0/4, respectively P = 0.028). Conclusion Non-mass breast lesions were successfully and accurately biopsied using cable-free VAB. The underestimation rate of ultrasound-detected non-mass lesion was significantly lower with VAB than with CCNB. Trial registration CRiS KCT0002267. PMID:28628656

  17. Demonstrations with a Vacuum: Old Demonstrations for New Vacuum Pumps.

    ERIC Educational Resources Information Center

    Greenslade, Thomas B., Jr.

    1989-01-01

    Explains mechanisms of 19th-century vacuum pumps. Describes demonstrations using the pump including guinea and feather tube, aurora tube, electric egg, Gassiots cascade, air mill, bell in vacuum, density and buoyancy of air, fountain in vacuum, mercury shower, palm and bladder glasses, Bacchus demonstration, pneumatic man-lifter, and Magdeburg…

  18. Note: A simple sample transfer alignment for ultra-high vacuum systems.

    PubMed

    Tamtögl, A; Carter, E A; Ward, D J; Avidor, N; Kole, P R; Jardine, A P; Allison, W

    2016-06-01

    The alignment of ultra-high-vacuum sample transfer systems can be problematic when there is no direct line of sight to assist the user. We present the design of a simple and cheap system which greatly simplifies the alignment of sample transfer devices. Our method is based on the adaptation of a commercial digital camera which provides live views from within the vacuum chamber. The images of the camera are further processed using an image recognition and processing code which determines any misalignments and reports them to the user. Installation has proven to be extremely useful in order to align the sample with respect to the transfer mechanism. Furthermore, the alignment software can be easily adapted for other systems.

  19. Predictors of shoulder dystocia at the time of operative vaginal delivery.

    PubMed

    Palatnik, Anna; Grobman, William A; Hellendag, Madeline G; Janetos, Timothy M; Gossett, Dana R; Miller, Emily S

    2016-11-01

    It remains uncertain whether clinical factors known prior to delivery can predict which women are more likely to experience shoulder dystocia in the setting of operative vaginal delivery. We sought to identify whether shoulder dystocia can be accurately predicted among women undergoing an operative vaginal delivery. This was a case-control study of women undergoing a low or outlet operative vaginal delivery from 2005 through 2014 in a single tertiary care center. Cases were defined as women who experienced a shoulder dystocia at the time of operative vaginal delivery. Controls consisted of women without a shoulder dystocia at the time of operative vaginal delivery. Variables previously identified to be associated with shoulder dystocia that could be known prior to delivery were abstracted from the medical records. Bivariable analyses and multivariable logistic regression were used to identify factors independently associated with shoulder dystocia. A receiver operating characteristic curve was created to evaluate the predictive value of the model for shoulder dystocia. Of the 4080 women who met inclusion criteria, shoulder dystocia occurred in 162 (4.0%) women. In bivariable analysis, maternal age, parity, body mass index, diabetes, chorioamnionitis, arrest disorder as an indication for an operative vaginal delivery, vacuum use, and estimated fetal weight >4 kg were significantly associated with shoulder dystocia. In multivariable analysis, parity, diabetes, chorioamnionitis, arrest disorder as an indication for operative vaginal delivery, vacuum use, and estimated fetal weight >4 kg remained independently associated with shoulder dystocia. The area under the curve for the generated receiver operating characteristic curve was 0.73 (95% confidence interval, 0.69-0.77), demonstrating only a modest ability to predict shoulder dystocia before performing an operative vaginal delivery. While risk factors for shoulder dystocia at the time of operative vaginal delivery

  20. Anal incontinence after two vaginal deliveries without obstetric anal sphincter rupture.

    PubMed

    Persson, Lisa K G; Sakse, Abelone; Langhoff-Roos, Jens; Jangö, Hanna

    2017-06-01

    To evaluate prevalence and risk factors for long-term anal incontinence in women with two prior vaginal deliveries without obstetric anal sphincter injury (OASIS) and to assess the impact of anal incontinence-related symptoms on quality of life. This is a nation-wide cross-sectional survey study. One thousand women who had a first vaginal delivery and a subsequent delivery, both without OASIS, between 1997 and 2008 in Denmark were identified in the Danish Medical Birth Registry. Women with more than two deliveries in total till 2012 were excluded at this stage. Of the 1000 women randomly identified, 763 were eligible and received a questionnaire. Maternal and obstetric data were retrieved from the national registry. The response rate was 58.3%. In total, 394 women were included for analysis after reviewing responses according to previously defined exclusion criteria. Median follow-up time was 9.8 years after the first delivery and 6.4 years after the second. The prevalence of flatal incontinence, fecal incontinence and fecal urgency were 11.7, 4.1, and 12.3%, respectively. Overall, 20.1% had any degree of anal incontinence and/or fecal urgency. In 6.3% these symptoms affected their quality of life. No maternal or obstetric factors including episiotomy and vacuum extraction were consistently associated with altered risk of anal incontinence in the multivariable analyses. Anal incontinence and fecal urgency is reported by one fifth of women with two vaginal deliveries without OASIS at long-term follow-up. Episiotomy or vacuum extraction did not alter the risk of long-term anal incontinence.

  1. Improved Vacuum Bazooka

    NASA Astrophysics Data System (ADS)

    Cockman, John

    2003-04-01

    This apparatus is a modification to the well-known "vacuum bazooka" (PIRA 2B30.70). My vacuum bazooka is easy to construct and demonstrate, requires no precise fittings, foil, or vacuum grease, and propels ping-pong balls at a tremendous velocity!

  2. Breast 3 T-MR imaging: indication for stereotactic vacuum-assisted breast biopsy.

    PubMed

    Yamamoto, Nobuko; Yoshizako, Takeshi; Yoshikawa, Kazuaki; Itakura, Masayuki; Maruyama, Riruke; Kitagaki, Hajime

    2014-01-01

    The purpose of this study was to assess indications for stereotactic vacuum-assisted breast biopsy (SVAB) evaluated by breast 3 T-magnetic resonance (3 T-MR) imaging in patients showing suspicious microcalcifications on mammography and negative ultrasound (US) findings. Fifty-five patients with 55 breast lesions showing suspicious microcalcifications on mammography and negative US findings underwent preoperative 3 T-MR examination including dynamic MR imaging. All patients underwent SVAB within 1 month of MR imaging. The pathological diagnosis of each breast lesion was made by examining tissues obtained by SVAB or radical/partial mastectomy. 3 T-MR imaging findings were evaluated by using the American College of Radiology Breast Imaging Reporting and Data System Atlas (BI-RADS-MRI) and then were correlated with the histopathological findings. When BI-RADS 4 and 5 MR imaging lesions were assumed to be malignant, the usefulness of 3 T-MR imaging was evaluated for diagnosis of impalpable breast lesions by SVAB among lesions with microcalcification detected by mammography and negative US findings. There were 21 malignant lesions, including 5 invasive ductal carcinomas, 16 lesions of ductal carcinoma in situ (DCIS). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of 3 T-MR imaging for deciding the indications for SVAB was 90.5%, 97.1%, 95.0%, 94.3%, and 94.5%, respectively. The one-false negative case was a DCIS with small enhancing lesions (0.5 mm). The one false-positive case was ductal adenoma with a linear ductal pattern of enhancement. 3 T-MR imaging may be useful for deciding the indications for SVAB in patients who have breast lesions with microcalcification that are impalpable and are detected by mammography and negative US findings. However, our findings should be considered preliminary and further prospective investigation is required.

  3. [Operative vaginal deliveries training].

    PubMed

    Dupuis, O

    2008-12-01

    The appropriate use of forceps, vacuums or spatulas facilitates the rapid delivery of foetuses faced with life-threatening situations. It also makes possible the relief of certain cases of prolonged second-stage labor. In France, operative vaginal delivery (OVD) accounts for approximately 10% of all births. OVD training aims to optimize maternal, as well as neonatal safety. It should enable trainees to indicate or contraindicate an OVD safely, as well as to choose the appropriate instrument, use it correctly, and master quality control principles. Traditional OVD training is confronted with both spatial and time-related limitations. Spatial constraints involve both the teacher and trainee who only have limited visual access to the pelvic canal, and the head of the foetus; the time constraint occurs whenever the OVD occurs in an emergency setting. These limitations have been further aggravated by new constraints: decreasing time dedicated to training (European safety rules prohibit work the day after night duty), increasing litigation, and constraints imposed by society. Training by means of simulation removes such limitations making it possible to both avoid exposing pregnant women to the hazards of traditional training, and adapt the training to the skills of each trainee. OVD training should include forceps, vacuums and the use of spatulas. The OVD skills of obstetricians should be audited regularly on both a personal and a confidential level. Such audits could be based on a method using a simulator. Prospective studies comparing traditional and simulation-based training should be encouraged.

  4. Impact of stereotactic 11-g vacuum-assisted breast biopsy on cost of diagnosis in Austria.

    PubMed

    Gruber, R; Walter, E; Helbich, T H

    2011-01-01

    To determine the frequency with which stereotactic 11-g vacuum-assisted breast biopsy (11-g SVAB) obviates an open surgical biopsy (OSB), to compare the costs of these two biopsy methods, and to estimate the potential cost savings attributable to 11-g SVAB in the diagnosis of suspicious breast lesions in patients in Austria. We retrospectively reviewed 318 consecutive breast lesions of BI-RADS categories IV and V (microcalcifications n=166; masses n=152) on which 11-g SVAB and OSB were performed. Cost savings were calculated using nationally allowed flat rates and patient charges. Costs were measured from a hospital and a socioeconomic perspective. Common clinical scenarios and sensitivity analyses assessed the extent of achievable cost savings. 11-g SVAB obviated the need for an OSB in 93 (29%) of 318 women. Overall cost savings per 11-g SVAB over OSB were € 242 per case from a hospital perspective, and € 422 per case from a socioeconomic perspective. The use of 11-g SVAB decreased the cost of diagnosis by 7% from a hospital perspective, and by 10% from a socioeconomic perspective. In Austria, annual national savings of over 5 million Euro could be realized with the use of 11-g SVAB for the diagnosis of suspicious breast lesions. Although savings per case are modest, the national health care system realizes significant cost reduction as women benefit from a faster and less invasive approach to diagnosis. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  5. Alternative model of birth to reduce the risk of assisted vaginal delivery and perineal trauma.

    PubMed

    Walker, Carolina; Rodríguez, Tania; Herranz, Ana; Espinosa, José A; Sánchez, Emília; Espuña-Pons, Montserrat

    2012-09-01

    This study was conducted to evaluate the effects of an alternative model of birth (AMB) on the incidence of assisted vaginal delivery (AVD) and perineal trauma (PT). One hundred ninety-nine women with epidural anesthesia were randomized to a traditional model of birth (TMB) (n = 96) or AMB (n = 103). Women in TMB pushed immediately after complete dilatation and delivered in lithotomy position. In AMB, women followed a postural changes protocol while they delayed pushing and used a specific lateral position for delivery. AMB was associated with a significant reduction in AVD compared with TMB (19.8% vs 42.1%, p<0.001). TMB was strongly associated with AVD (OR = 4.49; p< 0.05), which, in turn, was significantly associated with nulliparity (OR = 5.52; p<0.005) and fetal head unengaged at full dilatation (OR = 5.35; p<0.05). AMB significantly increased the intact perineum rate compared with TMB (40.3% vs 12.2%, p<0.001). Episiotomy rate was significantly reduced in AMB (21.0% vs 51.4%, p<0.001). A combination of postural changes during the passive expulsive phase of labor and lateral position during active pushing time is associated with reductions in AVD and PT.

  6. Demographic variations and clinical associations of episiotomy and severe perineal lacerations in vaginal delivery.

    PubMed

    Ogunyemi, Dotun; Manigat, Brandy; Marquis, Jesse; Bazargan, Mohsen

    2006-11-01

    Primiparity, birthweight, operative delivery and obstetrical complications contribute to episiotomy and severe perineal lacerations. Episiotomy correlates with Hispanics, while African Americans correlate with severe perineal lacerations. The purpose of this study was to identify risk factors for both episiotomy and severe perineal lacerations in a large population from a single institution. This was a review of 66,224 vaginal deliveries of African Americans or Hispanics delivering between 25-44 gestational weeks between 1981-2001. Univariate and multiple regression analysis were done as indicated. Independent predictors of episiotomy were: primiparity eight-fold, forceps delivery seven-fold, vacuum delivery five-fold, shoulder dystocia 3.6-fold, macrosomia 1.8-fold, epidural analgesia 1.6-fold, postdates 1.5-fold, Hispanics 1.4-fold. Independent predictors of severe perineal lacerations were; macrosomia seven-fold, episiotomy 4.5-fold, primiparity 4.4-fold, shoulder dystocia 3.6-fold, average birthweight 3.5-fold, forceps delivery 2.6-fold, vacuum delivery two-fold, epidural analgesia two-fold, African-American 1.5-fold. Nonreassuring fetal heart rate patterns, meconium and cord accidents appeared protective. Primiparous women with larger babies undergoing operative delivery with epidural analgesia are at risk for both episiotomy incisions and severe perineal lacerations. Though Hispanics are more likely to have an episiotomy, they are at significantly less risk for severe perineal lacerations compared to African Americans. Even though episiotomy is independently associated with severe perineal laceration, other factors such as macrosomia and primiparity are as important.

  7. The Classical Vacuum.

    ERIC Educational Resources Information Center

    Boyer, Timothy H.

    1985-01-01

    The classical vacuum of physics is not empty, but contains a distinctive pattern of electromagnetic fields. Discovery of the vacuum, thermal spectrum, classical electron theory, zero-point spectrum, and effects of acceleration are discussed. Connection between thermal radiation and the classical vacuum reveals unexpected unity in the laws of…

  8. Electroweak vacuum instability and renormalized Higgs field vacuum fluctuations in the inflationary universe

    NASA Astrophysics Data System (ADS)

    Kohri, Kazunori; Matsui, Hiroki

    2017-08-01

    In this work, we investigated the electroweak vacuum instability during or after inflation. In the inflationary Universe, i.e., de Sitter space, the vacuum field fluctuations < δ phi 2 > enlarge in proportion to the Hubble scale H2. Therefore, the large inflationary vacuum fluctuations of the Higgs field < δ phi 2 > are potentially catastrophic to trigger the vacuum transition to the negative-energy Planck-scale vacuum state and cause an immediate collapse of the Universe. However, the vacuum field fluctuations < δ phi 2 >, i.e., the vacuum expectation values have an ultraviolet divergence, and therefore a renormalization is necessary to estimate the physical effects of the vacuum transition. Thus, in this paper, we revisit the electroweak vacuum instability from the perspective of quantum field theory (QFT) in curved space-time, and discuss the dynamical behavior of the homogeneous Higgs field phi determined by the effective potential V eff( phi ) in curved space-time and the renormalized vacuum fluctuations < δ phi 2 >ren via adiabatic regularization and point-splitting regularization. We simply suppose that the Higgs field only couples the gravity via the non-minimal Higgs-gravity coupling ξ(μ). In this scenario, the electroweak vacuum stability is inevitably threatened by the dynamical behavior of the homogeneous Higgs field phi, or the formations of AdS domains or bubbles unless the Hubble scale is small enough H< ΛI .

  9. Dental Therapy Assistant: Quality of Restorations Placed and Finished.

    ERIC Educational Resources Information Center

    Heid, Theodore H.; Bair, Jeffrey H.

    The U.S. Army Dental Corps has implemented a new concept of dental care delivery, formally identified as the Improved Dental Care Delivery System. The concept is based on the conservation of professional manpower resources through the use of dental treatment teams employing expanded duty dental assistants. Dental Therapy Assistant (DTA) is the…

  10. Germanium detector vacuum encapsulation

    NASA Technical Reports Server (NTRS)

    Madden, N. W.; Malone, D. F.; Pehl, R. H.; Cork, C. P.; Luke, P. N.; Landis, D. A.; Pollard, M. J.

    1991-01-01

    This paper describes an encapsulation technology that should significantly improve the viability of germanium gamma-ray detectors for a number of important applications. A specialized vacuum chamber has been constructed in which the detector and the encapsulating module are processed in high vacuum. Very high vacuum conductance is achieved within the valveless encapsulating module. The detector module is then sealed without breaking the chamber vacuum. The details of the vacuum chamber, valveless module, processing, and sealing method are presented.

  11. Euclidean mirrors: enhanced vacuum decay from reflected instantons

    NASA Astrophysics Data System (ADS)

    Akal, Ibrahim; Moortgat-Pick, Gudrid

    2018-05-01

    We study the tunnelling of virtual matter–antimatter pairs from the quantum vacuum in the presence of a spatially uniform, time-dependent electric background composed of a strong, slow field superimposed with a weak, rapid field. After analytic continuation to Euclidean spacetime, we obtain from the instanton equations two critical points. While one of them is the closing point of the instanton path, the other serves as an Euclidean mirror which reflects and squeezes the instanton. It is this reflection and shrinking which is responsible for an enormous enhancement of the vacuum pair production rate. We discuss how important features of two different mechanisms can be analysed and understood via such a rotation in the complex plane. (a) Consistent with previous studies, we first discuss the standard assisted mechanism with a static strong field and certain weak fields with a distinct pole structure in order to show that the reflection takes place exactly at the poles. We also discuss the effect of possible sub-cycle structures. We extend this reflection picture then to weak fields which have no poles present and illustrate the effective reflections with explicit examples. An additional field strength dependence for the rate occurs in such cases. We analytically compute the characteristic threshold for the assisted mechanism given by the critical combined Keldysh parameter. We discuss significant differences between these two types of fields. For various backgrounds, we present the contributing instantons and perform analytical computations for the corresponding rates treating both fields nonperturbatively. (b) In addition, we also study the case with a nonstatic strong field which gives rise to the assisted dynamical mechanism. For different strong field profiles we investigate the impact on the critical combined Keldysh parameter. As an explicit example, we analytically compute the rate by employing the exact reflection points. The validity of the predictions

  12. Development of High Interruption Capability Vacuum Circuit Breaker -Technology of Vacuum Arc Control-

    NASA Astrophysics Data System (ADS)

    Niwa, Yoshimitsu; Kaneko, Eiji

    Vacuum circuit breakers (VCB) have been widely used for power distribution systems. Vacuum Interrupters, which are the current interruption unit, have been increased its interruption capability with the development of vacuum arc control technology by magnetic field. There are three major type electrodes: disk shaped electrodes, radial magnetic field electrodes, axial magnetic field (AMF) electrodes. In the disk shaped electrode, the vacuum arc between the electrodes is not controlled. In the AMF electrode, the vacuum arc is diffused and stabilized by an axial magnetic field, which is parallel to the arc current. In the last type of electrodes, the vacuum arc column is rotated by magnetic force generated by the current flowing in the electrodes. The interruption current and the voltage of one break VCB is increased to 100 kA, 144 kV respectively. This paper describes basic configurations and functions of VCB, vacuum arc control technology in vacuum interrupters, recent researches and applications of VCB.

  13. Electroweak vacuum instability and renormalized Higgs field vacuum fluctuations in the inflationary universe

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kohri, Kazunori; Matsui, Hiroki, E-mail: kohri@post.kek.jp, E-mail: matshiro@post.kek.jp

    In this work, we investigated the electroweak vacuum instability during or after inflation. In the inflationary Universe, i.e., de Sitter space, the vacuum field fluctuations < δ φ {sup 2} > enlarge in proportion to the Hubble scale H {sup 2}. Therefore, the large inflationary vacuum fluctuations of the Higgs field < δ φ {sup 2} > are potentially catastrophic to trigger the vacuum transition to the negative-energy Planck-scale vacuum state and cause an immediate collapse of the Universe. However, the vacuum field fluctuations < δ φ {sup 2} >, i.e., the vacuum expectation values have an ultraviolet divergence, andmore » therefore a renormalization is necessary to estimate the physical effects of the vacuum transition. Thus, in this paper, we revisit the electroweak vacuum instability from the perspective of quantum field theory (QFT) in curved space-time, and discuss the dynamical behavior of the homogeneous Higgs field φ determined by the effective potential V {sub eff}( φ ) in curved space-time and the renormalized vacuum fluctuations < δ φ {sup 2} >{sub ren} via adiabatic regularization and point-splitting regularization. We simply suppose that the Higgs field only couples the gravity via the non-minimal Higgs-gravity coupling ξ(μ). In this scenario, the electroweak vacuum stability is inevitably threatened by the dynamical behavior of the homogeneous Higgs field φ, or the formations of AdS domains or bubbles unless the Hubble scale is small enough H < Λ {sub I} .« less

  14. All atypia diagnosed at stereotactic vacuum-assisted breast biopsy do not need surgical excision.

    PubMed

    de Mascarel, Isabelle; Brouste, Véronique; Asad-Syed, Maryam; Hurtevent, Gabrielle; Macgrogan, Gaëtan

    2011-09-01

    The necessity of excision is debatable when atypia are diagnosed at stereotactic vacuum-assisted breast biopsy (microbiopsy). Among the 287 surgical excisions performed at Institut Bergonié from 1999 to 2009, we selected a case-control study group of 151 excisions; 52 involving all the diagnosed cancers and 99 randomly selected among the 235 excisions without cancer, following atypical microbiopsy (24 flat epithelial atypia; 50 atypical ductal hyperplasia; 14 lobular neoplasia; 63 mixed lesions). Mammographical calcification (type, extension, complete removal) and histological criteria of epithelial atypia (type, number of foci, size/extension), topography and microcalcification extension at microbiopsy were compared according to the presence or absence of cancer at excision. Factors associated with cancer at excision were Breast Imaging Reporting and Data System (BI-RADS5) lesions, large and/or multiple foci of mammographical calcifications, histological type, number, size and extension of atypical foci. Flat epithelial atypia alone was never associated with cancer at excision. BI-RADS5, atypical ductal hyperplasia (alone or predominant) and >3 foci of atypia were identified as independent pejorative factors. There was never any cancer at excision when these pejorative factors were absent (n=31). Presence of one (n=59), two (n=23) or three (n=14) factors was associated with cancer in 24, 15 and 13 cases with an odds ratio=5.8 (95% CI: 3-11.2) for each additional factor. We recommend that mammographical data and histological characteristics be taken into account in the decision-making process after diagnosis of atypia on microbiopsy. With experienced senologists and strict histological criteria, some patients could be spared surgery resulting in significant patient, financial and time advantages.

  15. [Treatment of septic olecranon and patellar bursitis by excision and vacuum-assisted closure therapy].

    PubMed

    Walter, G; Kemmerer, M; Hoffmann, R

    2013-08-01

    Treatment of septic olecranon and patellar bursitis differs considerably and is currently under discussion. We therefore performed a retrospective study of our patients with septic bursitis in the past 5 years. Between March 2007 and February 2012 we treated 79 patients with septic olecranon (n = 43) and patellar (n = 36) bursitis surgically: 61-males, 18 females, age 51 (range: 11-91) years. Four patients had not been treated before, 25 had suffered recurrences after 1-10 previous procedures, and 9 patients had not improved after conservative therapy. 34 patients presented with traumatic rupture or fistula of their bursae. In all cases we performed a radical bursectomy and vacuum-assisted therapy for 4 to 5 days. In addition, patients received systemic antibiotics. We phoned all patients and were successful in 57 cases (72 %). We questioned these patients for range of movement, limitations at work, pain, sensibility disorder, satisfaction with the result and further surgical procedures. In all cases we took tissue specimens for cultures, in 48 preparations histological examination was performed. Microbiological and histological results are discussed in detail. 40 patients were free of complaints, 15 complained of mild pain, 54 of 57 had unlimited range of motion. Minor discomforts at desk work were reported by 5 of 43 patients, 12 out of 36 patient reported discomfort when performing on their knees. There was no recurrence in the period of investigation. We recommend our treatment concept for septic olecranon and patellar bursitis because patient satisfaction is high and recurrences are reliably avoided. The soft tissue is spared, so that plastic covering procedures are seldom necessary. Georg Thieme Verlag KG Stuttgart · New York.

  16. Mode of delivery and risk of intracranial haemorrhage in newborns with severe haemophilia A: a multicentre study in Gulf region.

    PubMed

    Nazir, H F; Al Lawati, T; Beshlawi, I; AlSharidah, S; Elshinawy, M; Alkasim, F; Khanani, M F; Tarawa, A; Al Subhi, T; Alrawas, A; Al Riyami, W; Al Kindi, S; Al Saadi, K; Al-Lamki, S; Wali, Y

    2016-05-01

    The optimum mode of delivery in a known carrier of a haemophilia A is still an issue of debate. This study was conducted to report a multicentre experience in Gulf Cooperation Council (GCC) on the incidence of intracranial haemorrhage (ICH) in newborns with severe haemophilia A delivered by different modalities. We have conducted a retrospective/prospective multicentre cohort study including a total of seven hospitals distributed in four GCC countries between 1998 and Jan 2015. A total of 163 patient with severe haemophilia A (factor VIII <1%) were enrolled in this study, age ranged between 2 weeks to 18 years. Most of the patients were born by spontaneous vaginal delivery (SVD) (131, 80.4%), whereas 26 patients (16%) were born by CS and only six patients were born by instrumental delivery (3.7%), five of them by vacuum and one was delivered using forceps. Five out of 163 patients developed ICH during the first 2 weeks of life (3.1%). Two of them were born by SVD (2/131; 1.5%) and two were born by instrumental delivery (2/6; 33.3%). Only one patient among those who were born by caesarean section developed ICH (1/26; 3.8%). Assisted vaginal delivery was associated with a significant risk of ICH, in comparison to SVD and CS (P = 0.0093). Normal vaginal delivery is still considered a safe journey through the birth canal for haemophilic newborns particularly in this area of the world. Larger prospective studies might be needed to define an evidence-based optimal mode of delivery for the haemophilia carrier expecting an affected child. © 2015 John Wiley & Sons Ltd.

  17. Assisted-living spaces for end-users with complex needs: a proposed implementation and delivery model.

    PubMed

    Linskell, Jeremy; Bouamrane, Matt-Mouley

    2012-09-01

    An assisted living space (ALS) is a technology-enabled environment designed to allow people with complex health or social care needs to remain, and live independently, in their own home for longer. However, many challenges remain in order to deliver usable systems acceptable to a diverse range of stakeholders, including end-users, and their families and carers, as well as health and social care services. ALSs need to support activities of daily-living while allowing end-users to maintain important social connections. They must be dynamic, flexible and adaptable living environments. In this article, we provide an overview of the technological landscape of assisted-living technology (ALT) and recent policies to promote an increased adoption of ALT in Scotland. We discuss our experiences in implementing technology-supported ALSs and emphasise key lessons. Finally, we propose an iterative and pragmatic user-centred implementation model for delivering ALSs in complex-needs scenarios. This empirical model is derived from our past ALS implementations. The proposed model allows project stakeholders to identify requirements, allocate tasks and responsibilities, and identify appropriate technological solutions for the delivery of functional ALS systems. The model is generic and makes no assumptions on needs or technology solutions, nor on the technical knowledge, skills and experience of the stakeholders involved in the ALS design process.

  18. Planetary Regolith Delivery Systems for ISRU

    NASA Technical Reports Server (NTRS)

    Mantovani, James G.; Townsend, Ivan I., III

    2012-01-01

    The challenges associated with collecting regolith on a planetary surface and delivering it to an in-situ resource utilization system differ significantly from similar activities conducted on Earth. Since system maintenance on a planetary body can be difficult or impossible to do, high reliability and service life are expected of a regolith delivery system. Mission costs impose upper limits on power and mass. The regolith delivery system must provide a leak-tight interface between the near-vacuum planetary surface and the pressurized ISRU system. Regolith delivery in amounts ranging from a few grams to tens of kilograms may be required. Finally, the spent regolith must be removed from the ISRU chamber and returned to the planetary environment via dust tolerant valves capable of operating and sealing over a large temperature range. This paper will describe pneumatic and auger regolith transfer systems that have already been field tested for ISRU, and discuss other systems that await future field testing.

  19. Hyaluronic Acid Enhances Gene Delivery into the Cochlea

    PubMed Central

    Shibata, Seiji B.; Cortez, Sarah R.; Wiler, James A.; Swiderski, Donald L.

    2012-01-01

    Abstract Cochlear gene therapy can be a new avenue for the treatment of severe hearing loss by inducing regeneration or phenotypic rescue. One necessary step to establish this therapy is the development of a safe and feasible inoculation surgery, ideally without drilling the bony cochlear wall. The round window membrane (RWM) is accessible in the middle-ear space, but viral vectors placed on this membrane do not readily cross the membrane to the cochlear tissues. In an attempt to enhance permeability of the RWM, we applied hyaluronic acid (HA), a nontoxic and biodegradable reagent, onto the RWM of guinea pigs, prior to delivering an adenovirus carrying enhanced green fluorescent protein (eGFP) reporter gene (Ad-eGFP) at the same site. We examined distribution of eGFP in the cochlea 1 week after treatment, comparing delivery of the vector via the RWM, with or without HA, to delivery by a cochleostomy into the perilymph. We found that cochlear tissue treated with HA-assisted delivery of Ad-eGFP demonstrated wider expression of transgenes in cochlear cells than did tissue treated by cochleostomy injection. HA-assisted vector delivery facilitated expression in cells lining the scala media, which are less accessible and not transduced after perilymphatic injection. We assessed auditory function by measuring auditory brainstem responses and determined that thresholds were significantly better in the ears treated with HA-assisted Ad-eGFP placement on the RWM as compared with cochleostomy. Together, these data demonstrate that HA-assisted delivery of viral vectors provides an atraumatic and clinically feasible method to introduce transgenes into cochlear cells, thereby enhancing both research methods and future clinical application. PMID:22074321

  20. Hyaluronic acid enhances gene delivery into the cochlea.

    PubMed

    Shibata, Seiji B; Cortez, Sarah R; Wiler, James A; Swiderski, Donald L; Raphael, Yehoash

    2012-03-01

    Cochlear gene therapy can be a new avenue for the treatment of severe hearing loss by inducing regeneration or phenotypic rescue. One necessary step to establish this therapy is the development of a safe and feasible inoculation surgery, ideally without drilling the bony cochlear wall. The round window membrane (RWM) is accessible in the middle-ear space, but viral vectors placed on this membrane do not readily cross the membrane to the cochlear tissues. In an attempt to enhance permeability of the RWM, we applied hyaluronic acid (HA), a nontoxic and biodegradable reagent, onto the RWM of guinea pigs, prior to delivering an adenovirus carrying enhanced green fluorescent protein (eGFP) reporter gene (Ad-eGFP) at the same site. We examined distribution of eGFP in the cochlea 1 week after treatment, comparing delivery of the vector via the RWM, with or without HA, to delivery by a cochleostomy into the perilymph. We found that cochlear tissue treated with HA-assisted delivery of Ad-eGFP demonstrated wider expression of transgenes in cochlear cells than did tissue treated by cochleostomy injection. HA-assisted vector delivery facilitated expression in cells lining the scala media, which are less accessible and not transduced after perilymphatic injection. We assessed auditory function by measuring auditory brainstem responses and determined that thresholds were significantly better in the ears treated with HA-assisted Ad-eGFP placement on the RWM as compared with cochleostomy. Together, these data demonstrate that HA-assisted delivery of viral vectors provides an atraumatic and clinically feasible method to introduce transgenes into cochlear cells, thereby enhancing both research methods and future clinical application.

  1. Spatial and temporal profile of cisplatin delivery by ultrasound-assisted intravesical chemotherapy in a bladder cancer model.

    PubMed

    Sasaki, Noboru; Ishi, Kazuhiro; Kudo, Nobuki; Nakayama, Shouta M M; Nakamura, Kensuke; Morishita, Keitaro; Ohta, Hiroshi; Ishizuka, Mayumi; Takiguchi, Mitsuyoshi

    2017-01-01

    Non-muscle invasive bladder cancer is one of the most common tumors of the urinary tract. Despite the current multimodal therapy, recurrence and progression of disease have been challenging problems. We hereby introduced a new approach, ultrasound-assisted intravesical chemotherapy, intravesical instillation of chemotherapeutic agents and microbubbles followed by ultrasound exposure. We investigated the feasibility of the treatment for non-muscle invasive bladder cancer. In order to evaluate intracellular delivery and cytotoxic effect as a function to the thickness, we performed all experiments using a bladder cancer mimicking 3D culture model. Ultrasound-triggered microbubble cavitation increased both the intracellular platinum concentration and the cytotoxic effect of cisplatin at the thickness of 70 and 122 μm of the culture model. The duration of enhanced cytotoxic effect of cisplatin by ultrasound-triggered microbubble cavitation was approximately 1 hr. Based on the distance and duration of delivery, we further tested the feasibility of repetition of the treatment. Triple treatment increased the effective distance by 1.6-fold. Our results clearly showed spatial and temporal profile of delivery by ultrasound-triggered microbubble cavitation in a tumor-mimicking structure. Furthermore, we demonstrated that the increase in intracellular concentration results in the enhancement of the cytotoxic effect in a structure with the certain thickness. Repetition of ultrasound exposure would be treatment of choice in future clinical application. Our results suggest ultrasound-triggered microbubble cavitation can be repeatable and is promising for the local control of non-muscle invasive bladder cancer.

  2. Planning and Implementing Augmentative Communication Service Delivery, 2: Proceedings of the National Planners Conference on Assistive Device Service Delivery.

    ERIC Educational Resources Information Center

    Coston, Caroline A., Ed.

    The document consists of 30 author contributed chapters concerned with augmentative communication service delivery. Chapter titles and authors are: "Communication Options for Persons Who Cannot Speak: Planning for Service Delivery" (David Beukelman); "Planning Service Delivery Systems" (Roland Hahn II); "Planning Ohio's…

  3. Client-Centered Employee Assistance Services.

    ERIC Educational Resources Information Center

    Bayer, Darryl Lee

    This paper addresses delivery aspects and benefits of client-centered Employee Assistance Program (EAP) services through a review of the literature and research. EAP services are described as educational and mental health services utilized to assist employees and their families to respond constructively to job, personal, interpersonal or…

  4. Self-Assembly Assisted Fabrication of Dextran-Based Nanohydrogels with Reduction-Cleavable Junctions for Applications as Efficient Drug Delivery Systems

    PubMed Central

    Wang, Hao; Dai, Tingting; Zhou, Shuyan; Huang, Xiaoxiao; Li, Songying; Sun, Kang; Zhou, Guangdong; Dou, Hongjing

    2017-01-01

    In order to overcome the key challenge in improving both fabrication efficiency and their drug delivery capability of anti-cancer drug delivery systems (ACDDS), here polyacrylic acid (PAA) grafted dextran (Dex) nanohydrogels (NGs) with covalent crosslinked structure bearing redox sensitive disulfide crosslinking junctions (Dex-SS-PAA) were synthesized efficiently through a one-step self-assembly assisted methodology (SAA). The Dex-SS-PAA were subsequently conjugated with doxorubicin through an acid-labile hydrazone bond (Dex-SS-PAA-DOX). The in vitro drug release behavior, anti-cancer effects in vivo, and biosafety of the as-prepared acid- and redox-dual responsive biodegradable NGs were systematically investigated. The results revealed that the Dex-SS-PAA-DOX exhibited pH- and redox-controlled drug release, greatly reduced the toxicity of free DOX, while exhibiting a strong ability to inhibit the growth of MDA-MB-231 tumors. Our study demonstrated that the Dex-SS-PAA-DOX NGs are very promising candidates as ACDDS for anti-cancer therapeutics. PMID:28071743

  5. Self-Assembly Assisted Fabrication of Dextran-Based Nanohydrogels with Reduction-Cleavable Junctions for Applications as Efficient Drug Delivery Systems

    NASA Astrophysics Data System (ADS)

    Wang, Hao; Dai, Tingting; Zhou, Shuyan; Huang, Xiaoxiao; Li, Songying; Sun, Kang; Zhou, Guangdong; Dou, Hongjing

    2017-01-01

    In order to overcome the key challenge in improving both fabrication efficiency and their drug delivery capability of anti-cancer drug delivery systems (ACDDS), here polyacrylic acid (PAA) grafted dextran (Dex) nanohydrogels (NGs) with covalent crosslinked structure bearing redox sensitive disulfide crosslinking junctions (Dex-SS-PAA) were synthesized efficiently through a one-step self-assembly assisted methodology (SAA). The Dex-SS-PAA were subsequently conjugated with doxorubicin through an acid-labile hydrazone bond (Dex-SS-PAA-DOX). The in vitro drug release behavior, anti-cancer effects in vivo, and biosafety of the as-prepared acid- and redox-dual responsive biodegradable NGs were systematically investigated. The results revealed that the Dex-SS-PAA-DOX exhibited pH- and redox-controlled drug release, greatly reduced the toxicity of free DOX, while exhibiting a strong ability to inhibit the growth of MDA-MB-231 tumors. Our study demonstrated that the Dex-SS-PAA-DOX NGs are very promising candidates as ACDDS for anti-cancer therapeutics.

  6. Demographic variations and clinical associations of episiotomy and severe perineal lacerations in vaginal delivery.

    PubMed Central

    Ogunyemi, Dotun; Manigat, Brandy; Marquis, Jesse; Bazargan, Mohsen

    2006-01-01

    Primiparity, birthweight, operative delivery and obstetrical complications contribute to episiotomy and severe perineal lacerations. Episiotomy correlates with Hispanics, while African Americans correlate with severe perineal lacerations. OBJECTIVE: The purpose of this study was to identify risk factors for both episiotomy and severe perineal lacerations in a large population from a single institution. STUDY DESIGN: This was a review of 66,224 vaginal deliveries of African Americans or Hispanics delivering between 25-44 gestational weeks between 1981-2001. Univariate and multiple regression analysis were done as indicated. RESULTS: Independent predictors of episiotomy were: primiparity eight-fold, forceps delivery seven-fold, vacuum delivery five-fold, shoulder dystocia 3.6-fold, macrosomia 1.8-fold, epidural analgesia 1.6-fold, postdates 1.5-fold, Hispanics 1.4-fold. Independent predictors of severe perineal lacerations were; macrosomia seven-fold, episiotomy 4.5-fold, primiparity 4.4-fold, shoulder dystocia 3.6-fold, average birthweight 3.5-fold, forceps delivery 2.6-fold, vacuum delivery two-fold, epidural analgesia two-fold, African-American 1.5-fold. Nonreassuring fetal heart rate patterns, meconium and cord accidents appeared protective. CONCLUSION: Primiparous women with larger babies undergoing operative delivery with epidural analgesia are at risk for both episiotomy incisions and severe perineal lacerations. Though Hispanics are more likely to have an episiotomy, they are at significantly less risk for severe perineal lacerations compared to African Americans. Even though episiotomy is independently associated with severe perineal laceration, other factors such as macrosomia and primiparity are as important. PMID:17128701

  7. 7 CFR 1488.8 - Documents required after delivery.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... AGRICULTURAL COMMODITIES Financing of Export Sales of Agricultural Commodities From Private Stocks Under CCC... delivery. (a) CCC will purchase an exporter's account receivable only if the Treasurer, Commodity Credit... or Assistant Treasurer, CCC, after date of delivery of commodities exported or to be exported under...

  8. 7 CFR 1488.8 - Documents required after delivery.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... AGRICULTURAL COMMODITIES Financing of Export Sales of Agricultural Commodities From Private Stocks Under CCC... delivery. (a) CCC will purchase an exporter's account receivable only if the Treasurer, Commodity Credit... or Assistant Treasurer, CCC, after date of delivery of commodities exported or to be exported under...

  9. Instrumental delivery of the fetal head at the time of elective repeat cesarean: a randomized pilot study.

    PubMed

    Bofill, J A; Lencki, S G; Barhan, S; Ezenagu, L C

    2000-01-01

    We sought to ascertain whether the routine use of instruments, forceps or vacuum, at the time of elective repeat cesarean delivery, permits a delivery that is as safe for mother and infant and as easy for mother and physician as traditional manual delivery of the fetal head. In this prospective study 44 women undergoing elective repeat cesarean were randomized to deliver by Vacuum (V), Forceps (F), or by Manual (M) means. Groups were compared with regard to demographic variables and maternal and neonatal outcomes. Deliveries were timed from entry into the uterus until full delivery of the infant. Maternal pain scores were assessed using a 10-cm visual analog scale. There were no differences in demographic variables except that the M group had fewer women with up to two cesareans. A large percentage of women in each group were delivered with the randomized instrument. Use of the V did not demonstrate fewer extensions of the uterine incision or lesser amounts of blood loss as measured by serial hemoglobin determinations. There was a trend for the F group to require a longer period of time for delivery (p = 0.061). Women in the V group reported significantly lower pain scores (p = 0.015). There were no serious neonatal injuries. The routine use of instruments at the time of elective repeat cesarean delivery appears safe and effective.

  10. Radiation hard vacuum switch

    DOEpatents

    Boettcher, Gordon E.

    1990-01-01

    A vacuum switch with an isolated trigger probe which is not directly connected to the switching electrodes. The vacuum switch within the plasmatron is triggered by plasma expansion initiated by the trigger probe which travels through an opening to reach the vacuum switch elements. The plasma arc created is directed by the opening to the space between the anode and cathode of the vacuum switch to cause conduction.

  11. Radiation hard vacuum switch

    DOEpatents

    Boettcher, Gordon E.

    1990-03-06

    A vacuum switch with an isolated trigger probe which is not directly connected to the switching electrodes. The vacuum switch within the plasmatron is triggered by plasma expansion initiated by the trigger probe which travels through an opening to reach the vacuum switch elements. The plasma arc created is directed by the opening to the space between the anode and cathode of the vacuum switch to cause conduction.

  12. The role of the International Classification of Functioning, Disability, and Health and quality criteria for improving assistive technology service delivery in Europe.

    PubMed

    Steel, Emily J; Gelderblom, Gert Jan; de Witte, Luc P

    2012-02-01

    People with disabilities are entitled to access assistive technology (AT) to facilitate their full and effective participation in society and may reasonably expect to be central to the decision-making processes of services that provide these technologies. European projects have improved the knowledge and resources available for AT service delivery in many countries, but the outputs are not consistently implemented or published in scientific literature. This article examines European developments in AT service delivery and the barriers to its effective provision. Specifically, it analyzes the role of the International Classification of Functioning, Disability, and Health in service delivery improvement. Published scientific papers, as well as reports from and descriptions of European projects related to AT service delivery, were reviewed. The publications were analyzed in relation to six criteria for AT service delivery described in an earlier, major European project. The findings and recommendations from the publications are synthesized in this article to identify advances and gaps in AT service delivery and to assess the current status and direction of AT service delivery improvement in Europe. Multicountry projects have brought together AT researchers from across Europe to work together and produced promising results that are contextually relevant. Access to AT information and training of practitioners has improved, and efforts are being made to facilitate user involvement. More effort should be put into integrating research and resources from European projects into practice. Use of the International Classification of Functioning, Disability, and Health model and terminology may support coordination of service delivery systems. The AT research and practice communities in Europe may be able to learn from developments in North America, while continuing to work together, sharing resources and strategies, and communicating results internationally.

  13. Vernix caseosa peritonitis after vaginal delivery.

    PubMed

    Sadath, Shameema A; Abo Diba, Fathiya I; Nayak, Surendra; Shamali, Iman Al; Diejomaoh, Michael F

    2013-01-01

    Vernix caseosa peritonitis (VCP) is a very unusual complication caused by inflammatory response to amniotic fluid spilled into the maternal peritoneal cavity. Twenty-seven cases have been reported, and all occurred after cesarean section. We present a case of VCP following vaginal delivery; this may be the first case reported after vaginal delivery. Mrs. A, 28 years old, gravida 3, para 2, with one previous cesarean section, was admitted at 41 weeks gestation in active labor. Vacuum extraction was performed to deliver a healthy male baby, 4.410 kg, Apgar scores 7, 8. She developed fever, acute abdominal pain, and distension about 3 hours after delivery. A diagnosis of acute abdomen was made. Laparotomy was performed and it revealed neither uterine scar rupture nor other surgical emergencies, but 500 mL of turbid fluid and some cheesy material on the serosal surface of all viscera. Biopsies were taken. She had a course of antibiotics and her recovery was complete. Histology of the peritoneal fluid and tissue biopsy resulted in a diagnosis of VCP. Clinical diagnosis of peritonitis due to vernix caseosa should be considered in patients presenting postpartum with an acute abdomen after vaginal delivery.

  14. Long-term outcomes of sandwich ventral hernia repair paired with hybrid vacuum-assisted closure.

    PubMed

    Hicks, Caitlin W; Poruk, Katherine E; Baltodano, Pablo A; Soares, Kevin C; Azoury, Said C; Cooney, Carisa M; Cornell, Peter; Eckhauser, Frederic E

    2016-08-01

    Sandwich ventral hernia repair (SVHR) may reduce ventral hernia recurrence rates, although with an increased risk of surgical site occurrences (SSOs) and surgical site infections (SSIs). Previously, we found that a modified negative pressure wound therapy (hybrid vacuum-assisted closure [HVAC]) system reduced SSOs and SSIs after ventral hernia repair. We aimed to describe our outcomes after SVHR paired with HVAC closure. We conducted a 4-y retrospective review of all complex SVHRs (biologic mesh underlay and synthetic mesh overlay) with HVAC closure performed at our institution by a single surgeon. All patients had fascial defects that could not be reapproximated primarily using anterior component separation. Descriptive statistics were used to report the incidence of postoperative complications and hernia recurrence. A total of 60 patients (59.3 ± 11.4 y, 58.3% male, 75% American Society of Anesthesiologists class ≥3) with complex ventral hernias being underwent sandwich repair with HVAC closure. Major postoperative morbidity (Dindo-Clavien class ≥3) occurred in 14 (23.3%) patients, but incidence of SSO (n = 13, 21.7%) and SSI (n = 4, 6.7%) was low compared with historical reports. Median follow-up time for all patients was 12 mo (interquartile range 5.8-26.5 mo). Hernia recurrence occurred in eight patients (13.3%) after a median time of 20.6 months (interquartile range 16.4- 25.4 months). Use of a dual layer sandwich repair for complex abdominal wall reconstruction is associated with low rates of hernia recurrence at 1 year postoperatively. The addition of the HVAC closure system may reduce the risk of SSOs and SSIs previously reported with this technique and deserves consideration in future prospective studies assessing optimization of ventral hernia repair approaches. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Vacuum-assisted cell loading enables shear-free mammalian microfluidic culture

    PubMed Central

    Kolnik, Martin; Tsimring, Lev S; Hasty, Je

    2012-01-01

    Microfluidic perfusion cultures for mammalian cells provide a novel means for probing single-cell behavior but require the management of culture parameters such as flow-induced shear stress. Methods to eliminate shear stress generally focus on capturing cells in regions with high resistance to fluid flow. Here, we present a novel trapping design to easily and reliably load a high density of cells into culture chambers that are extremely isolated from potentially damaging flow effects. We utilize a transient on-chip vacuum to remove air from the culture chambers and rapidly replace the volume with a liquid cell suspension. We demonstrate the ability of this simple and robust method to load and culture three commonly used cell lines. We show how the incorporation of an on-chip function generator can be used for dynamic stimulation of cells during long-term continuous perfusion culture. PMID:22961584

  16. Economic evaluation of Vacuum Assisted Closure® Therapy for the treatment of diabetic foot ulcers in France.

    PubMed

    Whitehead, Sarah J; Forest-Bendien, Véronique L; Richard, Jean-Louis; Halimi, Serge; Van, Georges Ha; Trueman, Paul

    2011-02-01

    The objective of the study was to assess the cost-effectiveness of Vacuum Assisted Closure® (V.A.C.®) Therapy compared with advanced wound care (AWC) for the treatment of diabetic foot ulcers (DFUs) in France. A cost-effectiveness model intended to reflect the management of DFUs was updated for the French setting. The Markov model follows the progression of 1000 hypothetical patients over a 1-year period. The model was populated with French-specific data, obtained from published sources and clinical experts. The analysis evaluated costs and health outcomes, in terms of quality-adjusted life-years (QALYs), wounds healed and amputations, from the perspective of the payer. The patients treated with V.A.C.® Therapy experienced more QALYs (0.787 versus 0.784) and improved healing rates (50.2% versus 48.5%) at a lower total cost of care (€24,881 versus €28,855 per patient per year) when compared with AWC. Sensitivity analyses conducted around key model parameters indicated that the results were affected by hospital resource use and costs. DFU treatment using V.A.C.® Therapy in France was associated with lower costs, additional QALYs, more healed ulcers and fewer amputations than treatment with AWC. V.A.C.® Therapy was therefore found to be the dominant treatment option. © 2010 The Authors. © 2010 Blackwell Publishing Ltd and Medicalhelplines.com Inc.

  17. Skin graft secured by VAC (vacuum-assisted closure) therapy in chronic leg ulcers: A controlled randomized study.

    PubMed

    Leclercq, A; Labeille, B; Perrot, J-L; Vercherin, P; Cambazard, F

    2016-01-01

    Leg ulcers are a common condition. There have been very few studies of combined therapy involving VAC (vacuum-assisted closure) and skin graft. We performed a randomized controlled trial of VAC therapy vs. hydrocolloid dressings over 5 days following autologous grafting on chronic leg ulcers. The primary objective was to assess the difference in success (defined as a reduction in wound area of at least 50% at 1 month) between the two dressing methods. Forty-six patients with ulcers present for over one month were included. Following a 7-day hospitalization period, follow-up was performed for 3 months on an outpatient basis. Our study does not demonstrate a statistically significant difference, with a 45.8% success rate in the VAC group vs. 40.9% in the conventional dressing group (P=0.73). In the venous ulcer group, the success rate was 57.9% for VAC vs. 40% for conventional dressings (P=0.3). The difference in favor of VAC in this group was not statistically significant, most likely due to an insufficient number of patients studied. Our study does not demonstrate superiority of VAC associated with skin graft over conventional dressings. We observed more complications with VAC (40%) than with conventional dressings (23%) (P=0.06). Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  18. The Effect of Vacuum-Assisted Closure on the Bacterial Load and Type of Bacteria: A Systematic Review

    PubMed Central

    Patmo, Aryan S.P.; Krijnen, Pieta; Tuinebreijer, Wim E.; Breederveld, Roelf S.

    2014-01-01

    Significance: A high bacterial load interferes with the healing process of a wound. Vacuum-assisted closure (VAC) is a wound healing therapy that utilizes a dressing system that continuously or intermittently applies a negative pressure to the wound surface. Recent Advances: VAC stimulates wound healing, but data on changes in the bacterial load and changes in the bacterial spectrum are scarce. Critical Issues: While VAC supposedly removes bacteria from the treated wounds and therefore reduces the risk of infection, this relationship has not yet been clinically proven. If VAC increases the bacterial load instead of decreasing it, then this may be a reason not to use VAC on certain types of wounds. Only seven small and heterogeneous studies reporting on the relationship between VAC usage and the bacterial load and type of bacteria in the treated wounds in clinical practice were found in the literature. Although there is some low quality evidence that VAC therapy does not change the bacterial load, no definite conclusions on changes in the bacterial load and type of bacteria during VAC can be drawn. Future Directions: Prospectively monitoring changes in the bacterial load and bacterial spectrum in patients that will receive VAC treatment on indication might be an effective way to find out whether it should indeed be used on specific wounds. PMID:24804158

  19. Vacuum-assisted closure therapy increases local interleukin-8 and vascular endothelial growth factor levels in traumatic wounds.

    PubMed

    Labler, Ludwig; Rancan, Mario; Mica, Ladislav; Härter, Luc; Mihic-Probst, Daniela; Keel, Marius

    2009-03-01

    Clinical observations are suggesting accelerated granulation tissue formation in traumatic wounds treated with vacuum-assisted closure (VAC). Aim of this study was to determine the impact of VAC therapy versus alternative Epigard application on local inflammation and neovascularization in traumatic soft tissue wounds. Thirty-two patients with traumatic wounds requiring temporary coverage (VAC n = 16; Epigard n = 16) were included. At each change of dressing, samples of wound fluid and serum were collected (n = 80). The cytokines interleukin (IL)-6, IL-8, vascular endothelial growth factor (VEGF), and fibroblast growth factor-2 were measured by ELISA. Wound biopsies were examined histologically for inflammatory cells and degree of neovascularization present. All cytokines were found to be elevated in wound fluids during both VAC and Epigard treatment, whereas serum concentrations were negligible or not detectable. In wound fluids, significantly higher IL-8 (p < 0.001) and VEGF (p < 0.05) levels were detected during VAC therapy. Furthermore, histologic examination revealed increased neovascularization (p < 0.05) illustrated by CD31 and von Willebrand factor immunohistochemistry in wound biopsies of VAC treatment. In addition, there was an accumulation of neutrophils as well as an augmented expression of VEGF (p < 0.005) in VAC wound biopsies. This study suggests that VAC therapy of traumatic wounds leads to increased local IL-8 and VEGF concentrations, which may trigger accumulation of neutrophils and angiogenesis and thus, accelerate neovascularization.

  20. Vacuum fluctuations in an ancestor vacuum: A possible dark energy candidate

    NASA Astrophysics Data System (ADS)

    Aoki, Hajime; Iso, Satoshi; Lee, Da-Shin; Sekino, Yasuhiro; Yeh, Chen-Pin

    2018-02-01

    We consider an open universe created by bubble nucleation, and study possible effects of our "ancestor vacuum," a de Sitter space in which bubble nucleation occurred, on the present universe. We compute vacuum expectation values of the energy-momentum tensor for a minimally coupled scalar field, carefully taking into account the effect of the ancestor vacuum by the Euclidean prescription. We pay particular attention to the so-called supercurvature mode, a non-normalizable mode on a spatial slice of the open universe, which has been known to exist for sufficiently light fields. This mode decays in time most slowly, and may leave residual effects of the ancestor vacuum, potentially observable in the present universe. We point out that the vacuum energy of the quantum field can be regarded as dark energy if mass of the field is of order the present Hubble parameter or smaller. We obtain preliminary results for the dark energy equation of state w (z ) as a function of the redshift.

  1. On the feasibility of the computational modelling of the endoluminal vacuum-assisted closure of an oesophageal anastomotic leakage

    PubMed Central

    Bellomo, Facundo J.; Rosales, Iván; del Castillo, Luis F.; Sánchez, Ricardo; Turon, Pau

    2018-01-01

    Endoluminal vacuum-assisted closure (E-VAC) is a promising therapy to treat anastomotic leakages of the oesophagus and bowel which are associated with high morbidity and mortality rates. An open-pore polyurethane foam is introduced into the leakage cavity and connected to a device that applies a suction pressure to accelerate the closure of the defect. Computational analysis of this healing process can advance our understanding of the biomechanical mechanisms at play. To this aim, we use a dual-stage finite-element analysis in which (i) the structural problem addresses the cavity reduction caused by the suction and (ii) a new constitutive formulation models tissue healing via permanent deformations coupled to a stiffness increase. The numerical implementation in an in-house code is described and a qualitative example illustrates the basic characteristics of the model. The computational model successfully reproduces the generic closure of an anastomotic leakage cavity, supporting the hypothesis that suction pressure promotes healing by means of the aforementioned mechanisms. However, the current framework needs to be enriched with empirical data to help advance device designs and treatment guidelines. Nonetheless, this conceptual study confirms that computational analysis can reproduce E-VAC of anastomotic leakages and establishes the bases for better understanding the mechanobiology of anastomotic defect healing. PMID:29515846

  2. Gold nanoclusters-assisted delivery of NGF siRNA for effective treatment of pancreatic cancer

    PubMed Central

    Lei, Yifeng; Tang, Lixue; Xie, Yangzhouyun; Xianyu, Yunlei; Zhang, Lingmin; Wang, Peng; Hamada, Yoh; Jiang, Kai; Zheng, Wenfu; Jiang, Xingyu

    2017-01-01

    Pancreatic cancer is one of the deadliest human cancers, whose progression is highly dependent on the nervous microenvironment. The suppression of gene expression of nerve growth factor (NGF) may have great potential in pancreatic cancer treatment. Here we show that gold nanocluster-assisted delivery of siRNA of NGF (GNC–siRNA) allows efficient NGF gene silencing and pancreatic cancer treatment. The GNC–siRNA complex increases the stability of siRNA in serum, prolongs the circulation lifetime of siRNA in blood and enhances the cellular uptake and tumour accumulation of siRNA. The GNC–siRNA complex potently downregulates the NGF expression in Panc-1 cells and in pancreatic tumours, and effectively inhibits the tumour progression in three pancreatic tumour models (subcutaneous model, orthotopic model and patient-derived xenograft model) without adverse effects. Our study constitutes a straightforward but effective approach to inhibit pancreatic cancer via NGF knockdown, suggesting a promising therapeutic direction for pancreatic cancer. PMID:28440296

  3. Gold nanoclusters-assisted delivery of NGF siRNA for effective treatment of pancreatic cancer

    NASA Astrophysics Data System (ADS)

    Lei, Yifeng; Tang, Lixue; Xie, Yangzhouyun; Xianyu, Yunlei; Zhang, Lingmin; Wang, Peng; Hamada, Yoh; Jiang, Kai; Zheng, Wenfu; Jiang, Xingyu

    2017-04-01

    Pancreatic cancer is one of the deadliest human cancers, whose progression is highly dependent on the nervous microenvironment. The suppression of gene expression of nerve growth factor (NGF) may have great potential in pancreatic cancer treatment. Here we show that gold nanocluster-assisted delivery of siRNA of NGF (GNC-siRNA) allows efficient NGF gene silencing and pancreatic cancer treatment. The GNC-siRNA complex increases the stability of siRNA in serum, prolongs the circulation lifetime of siRNA in blood and enhances the cellular uptake and tumour accumulation of siRNA. The GNC-siRNA complex potently downregulates the NGF expression in Panc-1 cells and in pancreatic tumours, and effectively inhibits the tumour progression in three pancreatic tumour models (subcutaneous model, orthotopic model and patient-derived xenograft model) without adverse effects. Our study constitutes a straightforward but effective approach to inhibit pancreatic cancer via NGF knockdown, suggesting a promising therapeutic direction for pancreatic cancer.

  4. Vacuum Virtues

    ERIC Educational Resources Information Center

    Rathey, Allen

    2007-01-01

    Upright vacuums, like cars, vary in quality, features and performance. Like automobiles, some uprights are reliable, others may be problematic, and some become a problem as a result of neglect or improper use. So, how do education institutions make an informed choice and, having done so, ensure that an upright vacuum goes the distance? In this…

  5. An experimental study of microneedle-assisted microparticle delivery.

    PubMed

    Zhang, Dongwei; Das, Diganta B; Rielly, Chris D

    2013-10-01

    A set of well-defined experiments has been carried out to explore whether microneedles (MNs) can enhance the penetration depths of microparticles moving at high velocity such as those expected in gene guns for delivery of gene-loaded microparticles into target tissues. These experiments are based on applying solid MNs that are used to reduce the effect of mechanical barrier function of the target so as to allow delivery of microparticles at less imposed pressure as compared with most typical gene guns. Further, a low-cost material, namely, biomedical-grade stainless steel microparticle with size ranging between 1 and 20 μm, has been used in this study. The microparticles are compressed and bound in the form of a cylindrical pellet and mounted on a ground slide, which are then accelerated together by compressed air through a barrel. When the ground slide reaches the end of the barrel, the pellet is separated from the ground slide and is broken down into particle form by a mesh that is placed at the end of the barrel. Subsequently, these particles penetrate into the target. This paper investigates the implications of velocity of the pellet along with various other important factors that affect the particle delivery into the target. Our results suggest that the particle passage increases with an increase in pressure, mesh pore size, and decreases with increase in polyvinylpyrrolidone concentration. Most importantly, it is shown that MNs increase the penetration depths of the particles. © 2013 Wiley Periodicals, Inc. and the American Pharmacists Association.

  6. Vacuum impregnation: a promising way for mineral fortification in potato porous matrix (potato chips).

    PubMed

    Joshi, Alka; Kar, A; Rudra, S G; Sagar, V R; Varghese, E; Lad, M; Khan, I; Singh, B

    2016-12-01

    Potato chips can be considered as an ideal carrier for targeted nutrient/s delivery as mostly consumed by the vulnerable group (children and teen agers). The present study was planned to fortifiy potato chips with calcium (Calcium lactate) and zinc (Zinc sulphate) using vacuum impregnation technique. At about 70-80 mm Hg vacuum pressure, maximum level of impregnation of both the minerals was achieved. Results showed that after optimization, calcium lactate at 4.81%, zinc sulphate at 0.72%, and vacuum of 33.53 mm Hg with restoration period of 19.52 min can fortify potato chips that can fulfil 10 and 21% need of calcium and zinc, respectively of targeted group (age 4-17 years). The present research work has shown that through this technique, fortification can be done in potato chips which are generally considered as a poor source of minerals. Further to make potato chips more fit to health conscious consumers, rather frying microwaving was done to develop mineral fortified low fat potato chips.

  7. Microfabricated triggered vacuum switch

    DOEpatents

    Roesler, Alexander W [Tijeras, NM; Schare, Joshua M [Albuquerque, NM; Bunch, Kyle [Albuquerque, NM

    2010-05-11

    A microfabricated vacuum switch is disclosed which includes a substrate upon which an anode, cathode and trigger electrode are located. A cover is sealed over the substrate under vacuum to complete the vacuum switch. In some embodiments of the present invention, a metal cover can be used in place of the trigger electrode on the substrate. Materials used for the vacuum switch are compatible with high vacuum, relatively high temperature processing. These materials include molybdenum, niobium, copper, tungsten, aluminum and alloys thereof for the anode and cathode. Carbon in the form of graphitic carbon, a diamond-like material, or carbon nanotubes can be used in the trigger electrode. Channels can be optionally formed in the substrate to mitigate against surface breakdown.

  8. Simple technique of talc delivery for video-assisted talc pleurodesis.

    PubMed

    Jutley, Rajwinder S; Waqar, Salman; Raha, Neil; Fenton, Paul; Sarkar, Pradip K

    2009-02-01

    It has been proven that talc is the sclerosant of choice for pleurodesis, especially for malignant effusions. Uniform talc deposition on the visceral pleura is often difficult, resulting in clump deposition with the use of an atomizer or bladder syringe delivery apparatus. We have devised a simple sterile apparatus that allows the operator to retain full control over the talc delivery rate and coat the lung uniformly under direct vision using a pressurized system.

  9. Influence of Gap Distance on Vacuum Arc Characteristics of Cup Type AMF Electrode in Vacuum Interrupters

    NASA Astrophysics Data System (ADS)

    Cheng, Shaoyong; Xiu, Shixin; Wang, Jimei; Shen, Zhengchao

    2006-11-01

    The greenhouse effect of SF6 is a great concern today. The development of high voltage vacuum circuit breakers becomes more important. The vacuum circuit breaker has minimum pollution to the environment. The vacuum interrupter is the key part of a vacuum circuit breaker. The interrupting characteristics in vacuum and arc-controlling technique are the main problems to be solved for a longer gap distance in developing high voltage vacuum interrupters. To understand the vacuum arc characteristics and provide effective technique to control vacuum arc in a long gap distance, the arc mode transition of a cup-type axial magnetic field electrode is observed by a high-speed charge coupled device (CCD) video camera under different gap distances while the arc voltage and arc current are recorded. The controlling ability of the axial magnetic field on vacuum arc obviously decreases when the gap distance is longer than 40 mm. The noise components and mean value of the arc voltage significantly increase. The effective method for controlling the vacuum arc characteristics is provided by long gap distances based on the test results. The test results can be used as a reference to develop high voltage and large capacity vacuum interrupters.

  10. 7 CFR 652.6 - Department delivery of technical services.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 6 2010-01-01 2010-01-01 false Department delivery of technical services. 652.6... CONSERVATION SERVICE, DEPARTMENT OF AGRICULTURE SUPPORT ACTIVITIES TECHNICAL SERVICE PROVIDER ASSISTANCE General Provisions § 652.6 Department delivery of technical services. (a) The Department may enter into a...

  11. Operative vaginal delivery and invasive procedures in pregnancy among women living with HIV.

    PubMed

    Peters, Helen; Francis, Kate; Harding, Kate; Tookey, Pat A; Thorne, Claire

    2017-03-01

    To describe the use and outcomes of operative delivery and invasive procedures in pregnancy amongst women living with HIV. The National Study of HIV in Pregnancy and Childhood (NSHPC) is a comprehensive population-based surveillance study in the UK and Ireland. The NSHPC has collected data on operative delivery since 2008, and invasive procedures in pregnancy (amniocentesis, cordocentesis, chorionic villus sampling) from 2012. Descriptive analyses were conducted on 278 pregnancies expected to deliver from 1 January 2008 with outcome reported to the NSHPC by 31 March 2016. Among 9372 pregnancies in 2008-2016, there were 9072 livebirths with 251 operative deliveries and 27 invasive procedures in pregnancy reported. Information was available for 3023/3490 vaginal deliveries, and use of forceps or vacuum reported in 251deliveries (8.2%), increasing over calendar time to almost 10% by 2014-16. Forceps were used twice as often as vacuum delivery, and forceps use increased over time. One infant delivered operatively is known to have acquired HIV. From 2012 there were 4063 pregnancies resulting in 3952 livebirths, 83 terminations and 28 stillbirths. 2163/4063 had information on use (or not) of invasive procedures in pregnancy. Amniocentesis was reported in 25/2163 pregnancies, there was one report of chorionic villus sampling and one of cordocentesis. There were no reported transmissions following invasive procedures in pregnancy. This is the largest study to date to report on operative delivery in women living with HIV on combined antiretroviral therapy (cART), and provides an up-to-date picture of invasive procedures during pregnancy in this group. Findings from this comprehensive national study are reassuring but numbers are currently low; on-going monitoring is crucial as obstetric care of women with HIV becomes normalised. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. In Vivo Delivery of Nanoparticles into Plant Leaves.

    PubMed

    Wu, Honghong; Santana, Israel; Dansie, Joshua; Giraldo, Juan P

    2017-12-14

    Plant nanobiotechnology is an interdisciplinary field at the interface of nanotechnology and plant biology that aims to utilize nanomaterials as tools to study, augment or impart novel plant functions. The delivery of nanoparticles to plants in vivo is a key initial step to investigate plant nanoparticle interactions and the impact of nanoparticles on plant function. Quantum dots are smaller than plant cell wall pores, have versatile surface chemistry, bright fluorescence and do not photobleach, making them ideal for the study of nanoparticle uptake, transport, and distribution in plants by widely available confocal microscopy tools. Herein, we describe three different methods for quantum dot delivery into leaves of living plants: leaf lamina infiltration, whole shoot vacuum infiltration, and root to leaf translocation. These methods can be potentially extended to other nanoparticles, including nanosensors and drug delivery nanoparticles. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.

  13. Interdisciplinary consensus on the uses and technique of MR-guided vacuum-assisted breast biopsy (VAB): results of a European consensus meeting.

    PubMed

    Heywang-Köbrunner, Sylvia H; Sinnatamby, Ruchi; Lebeau, Annette; Lebrecht, Antje; Britton, Peter D; Schreer, Ingrid

    2009-11-01

    Quality assurance of MR-guided vacuum-assisted breast biopsy (VAB). A consensus was achieved based on the existing literature and experience of an interdisciplinary group comprising European specialists in breast imaging and VAB. Full imaging work-up must be completed according to existing standards before an indication for MR-guided VAB is established. The procedure should be reserved for lesions demonstrable by MRI alone. Acquisition of >24 cores (11-Gauge) should be routinely attempted, with the intention of sufficiently removing small lesions for accurate diagnosis. Following biopsy the patient should be re-imaged to demonstrate the biopsy site and its proximity to the lesion and hence the likely accuracy of the sampling. All patients should be discussed in a regular interdisciplinary conference and a documented consensus reached regarding patient management. Regular audit and review of all MR-guided VAB results and subsequent follow-up are recommended. This consensus includes protocols for the indication, performance parameters, interdisciplinary interpretation therapeutic recommendation, documentation and follow-up of MR-guided VAB. It does not replace official recommendations for percutaneous biopsy.

  14. A Quality Improvement System to Manage Feeding Assistance Care in Assisted-Living.

    PubMed

    Simmons, Sandra F; Coelho, Chris S; Sandler, Andrew; Schnelle, John F

    2018-03-01

    To describe a feasible quality improvement system to manage feeding assistance care processes in an assisted living facility (ALF) that provides dementia care and the use of these data to maintain the quality of daily care provision and prevent unintentional weight loss. Supervisory ALF staff used a standardized observational protocol to assess feeding assistance care quality during and between meals for 12 consecutive months for 53 residents receiving dementia care. Direct care staff received feedback about the quality of assistance and consistency of between-meal snack delivery for residents with low meal intake and/or weight loss. On average, 78.4% of the ALF residents consumed more than one-half of each served meal and/or received staff assistance during meals to promote consumption over the 12 months. An average of 79.7% of the residents were offered snacks between meals twice per day. The prevalence of unintentional weight loss averaged 1.3% across 12 months. A quality improvement system resulted in sustained levels of mealtime feeding assistance and between-meal snack delivery and a low prevalence of weight loss among ALF residents receiving dementia care. Given that many ALF residents receiving dementia care are likely to be at risk for low oral intake and unintentional weight loss, ALFs should implement a quality improvement system similar to that described in this project, despite the absence of regulations to do so. Copyright © 2018 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  15. Oleic acid-enhanced transdermal delivery pathways of fluorescent nanoparticles

    NASA Astrophysics Data System (ADS)

    Lo, Wen; Ghazaryan, Ara; Tso, Chien-Hsin; Hu, Po-Sheng; Chen, Wei-Liang; Kuo, Tsung-Rong; Lin, Sung-Jan; Chen, Shean-Jen; Chen, Chia-Chun; Dong, Chen-Yuan

    2012-05-01

    Transdermal delivery of nanocarriers provides an alternative pathway to transport therapeutic agents, alleviating pain, improving compliance of patients, and increasing overall effectiveness of delivery. In this work, enhancement of transdermal delivery of fluorescent nanoparticles and sulforhodamine B with assistance of oleic acid was visualized utilizing multiphoton microscopy (MPM) and analyzed quantitatively using multi-photon excitation-induced fluorescent signals. Results of MPM imaging and MPM intensity-based spatial depth-dependent analysis showed that oleic acid is effective in facilitating transdermal delivery of nanoparticles.

  16. Guidelines for Psychological Practice in Health Care Delivery Systems

    ERIC Educational Resources Information Center

    American Psychologist, 2013

    2013-01-01

    Psychologists practice in an increasingly diverse range of health care delivery systems. The following guidelines are intended to assist psychologists, other health care providers, administrators in health care delivery systems, and the public to conceptualize the roles and responsibilities of psychologists in these diverse contexts. These…

  17. Effect of vacuum-assisted closure combined with open bone grafting to promote rabbit bone graft vascularization.

    PubMed

    Hu, Chao; Zhang, Taogen; Ren, Bin; Deng, Zhouming; Cai, Lin; Lei, Jun; Ping, Ansong

    2015-04-27

    Patients with composite bone non-union and soft tissue defects are difficult to treat. Vacuum-assisted closure (VAC) combined with open bone grafting is one of the most effective treatments at present. The aim of the present study was to preliminarily investigate the effect and mechanism of VAC combined with open bone grafting to promote rabbit bone graft vascularization, and to propose a theoretical basis for clinical work. Twenty-four New Zealand white rabbits were randomly divided into an experimental and a control group. Allogeneic bones were grafted and banded with the proximal femur with a suture. The experimental group had VAC whereas the control group had normal wound closure. The bone vascularization rate was compared based on X-ray imaging, fluorescent bone labeling (labeled tetracycline hydrochloride and calcein), calcium content in the callus, and expression of fibroblast growth factor-2 (FGF-2) in bone allografts by Western blot analysis at the 4th, 8th, and 12th week after surgery. At the 4th, 8th, and 12th week after surgery, the results of the tests demonstrated that the callus was larger, contained more calcium (p<0.05), and expressed FGF-2 at higher levels (p<0.05) in the experimental group than in the control group. Fluorescent bone labeling showed the distance between the two fluorescent ribbons was significantly shorter in the control group than in the experimental group at the 8th and 12th week after surgery. VAC combined with open bone grafting promoted rabbit bone graft vascularization.

  18. Optimal application of the Contura multilumen balloon breast brachytherapy catheter vacuum port to deliver accelerated partial breast irradiation.

    PubMed

    Tokita, Kenneth M; Cuttino, Laurie W; Vicini, Frank A; Arthur, Douglas W; Todor, Dorin A; Julian, Thomas B; Lyden, Maureen R

    2011-01-01

    The impact of using the Contura multilumen balloon (MLB) (SenoRx, Inc., Irvine, CA) breast brachytherapy catheter's vacuum port in patients treated with accelerated partial breast irradiation (APBI) was analyzed. Data from 32 patients at two sites were reviewed. Variables analyzed included the seroma fluid (SF):air volume around the MLB before and after vacuum port use and on its ability to improve (1) the eligibility of patients for APBI and (2) dose coverage of the planning target volume for evaluation (PTV_EVAL) in eligible patients. The median SF/air volume before vacuum removal was 6.8 cc vs. 0.8 cc after vacuum removal (median reduction in SF/air volume was 90.5%). Before vacuum port use, the median SF/air volume expressed as percentage of the PTV_EVAL was 7.8% (range, 1.9-26.6) in all patients. After application of the vacuum, this was reduced to 1.2%. Before vacuum port use, 10 (31.3%) patients were not considered acceptable candidates for APBI because the SF/air volume:PTV_EVAL ratio (SF:PTV) was greater than 10% (range, 10.1-26.6%; median, 15.2%). After vacuum port use, the median SF:PTV ratio was 1.6% for a median reduction of 91.5%. In addition, the percentage of the prescribed dose covering greater than or equal to 90% of the PTV_EVAL proportionally increased a median of 8% (range, 3-10%) in eligible patients. Use of the Contura MLB vacuum port significantly improved the conformity of the target tissue to the balloon surface, leading to reproducible dose delivery and increased target volume coverage. In addition, application of the vacuum allowed the safe treatment of unacceptable patients with APBI. Copyright © 2011 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  19. Vacuum probe surface sampler

    NASA Technical Reports Server (NTRS)

    Zahlava, B. A. (Inventor)

    1973-01-01

    A vacuum probe surface sampler is described for rapidly sampling relatively large surface areas which possess relatively light loading densities of micro-organism, drug particles or the like. A vacuum head with a hollow handle connected to a suitable vacuum source is frictionally attached to a cone assembly terminating in a flared tip adapted to be passed over the surface to be sampled. A fine mesh screen carried by the vacuum head provides support for a membrane filter which collects the microorganisms or other particles. The head assembly is easily removed from the cone assembly without contacting the cone assembly with human hands.

  20. Effects of vacuum suctioning and strategic drape tenting on oxygen concentration in a simulated surgical field.

    PubMed

    Kung, Theodore A; Kong, Sarah W; Aliu, Oluseyi; Azizi, Jahan; Kai, Salim; Cederna, Paul S

    2016-02-01

    To investigate the isolated and combined effects of vacuum suctioning and strategic drape tenting on oxygen concentration in an experimental setting. Experimental. Clinical simulation center of a university-affiliated hospital. Mannequin simulation of a patient undergoing facial surgery under sedation anesthesia. Supplemental oxygen was delivered via nasal cannula. Vacuum suctioning and strategic drape tenting. The experimental trials entailed measuring oxygen concentration around the nasal cannula continuously either in the presence or absence of a standard operating room vacuum suction system and strategic tenting of surgical drapes. The primary outcome was the time required for oxygen concentration to reach 21%. In the control group (without suction or strategic tenting), a mean time of 180 seconds elapsed until the measured oxygen concentration reached 21% after cessation of oxygen delivery. Use of a vacuum suction device alone (110 seconds; P < .01) or in combination with strategic tenting (110 seconds; P < .01) significantly reduced this time. No significant benefit was seen when tenting was used alone (160 seconds; P < .30). Use of a vacuum suction device during surgery will lower local oxygen concentration, and this in turn may decrease the risk of operating room fires. Although strategic tenting of surgical drapes has a theoretical benefit to decreasing the pooling of oxygen around the surgical site, further investigation is necessary before its routine use is recommended. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Assessing the Impact of U.S. Food Assistance Delivery Policies on Child Mortality in Northern Kenya.

    PubMed

    Nikulkov, Alex; Barrett, Christopher B; Mude, Andrew G; Wein, Lawrence M

    2016-01-01

    The U.S. is the main country in the world that delivers its food assistance primarily via transoceanic shipments of commodity-based in-kind food. This approach is costlier and less timely than cash-based assistance, which includes cash transfers, food vouchers, and local and regional procurement, where food is bought in or nearby the recipient country. The U.S.'s approach is exacerbated by a requirement that half of its transoceanic food shipments need to be sent on U.S.-flag vessels. We estimate the effect of these U.S. food assistance distribution policies on child mortality in northern Kenya by formulating and optimizing a supply chain model. In our model, monthly orders of transoceanic shipments and cash-based interventions are chosen to minimize child mortality subject to an annual budget constraint and to policy constraints on the allowable proportions of cash-based interventions and non-US-flag shipments. By varying the restrictiveness of these policy constraints, we assess the impact of possible changes in U.S. food aid policies on child mortality. The model includes an existing regression model that uses household survey data and geospatial data to forecast the mean mid-upper-arm circumference Z scores among children in a community, and allows food assistance to increase Z scores, and Z scores to influence mortality rates. We find that cash-based interventions are a much more powerful policy lever than the U.S.-flag vessel requirement: switching to cash-based interventions reduces child mortality from 4.4% to 3.7% (a 16.2% relative reduction) in our model, whereas eliminating the U.S.-flag vessel restriction without increasing the use of cash-based interventions generates a relative reduction in child mortality of only 1.1%. The great majority of the gains achieved by cash-based interventions are due to their reduced cost, not their reduced delivery lead times; i.e., the reduction of shipping expenses allows for more food to be delivered, which reduces

  2. Assessing the Impact of U.S. Food Assistance Delivery Policies on Child Mortality in Northern Kenya

    PubMed Central

    Nikulkov, Alex; Barrett, Christopher B.; Mude, Andrew G.; Wein, Lawrence M.

    2016-01-01

    The U.S. is the main country in the world that delivers its food assistance primarily via transoceanic shipments of commodity-based in-kind food. This approach is costlier and less timely than cash-based assistance, which includes cash transfers, food vouchers, and local and regional procurement, where food is bought in or nearby the recipient country. The U.S.’s approach is exacerbated by a requirement that half of its transoceanic food shipments need to be sent on U.S.-flag vessels. We estimate the effect of these U.S. food assistance distribution policies on child mortality in northern Kenya by formulating and optimizing a supply chain model. In our model, monthly orders of transoceanic shipments and cash-based interventions are chosen to minimize child mortality subject to an annual budget constraint and to policy constraints on the allowable proportions of cash-based interventions and non-US-flag shipments. By varying the restrictiveness of these policy constraints, we assess the impact of possible changes in U.S. food aid policies on child mortality. The model includes an existing regression model that uses household survey data and geospatial data to forecast the mean mid-upper-arm circumference Z scores among children in a community, and allows food assistance to increase Z scores, and Z scores to influence mortality rates. We find that cash-based interventions are a much more powerful policy lever than the U.S.-flag vessel requirement: switching to cash-based interventions reduces child mortality from 4.4% to 3.7% (a 16.2% relative reduction) in our model, whereas eliminating the U.S.-flag vessel restriction without increasing the use of cash-based interventions generates a relative reduction in child mortality of only 1.1%. The great majority of the gains achieved by cash-based interventions are due to their reduced cost, not their reduced delivery lead times; i.e., the reduction of shipping expenses allows for more food to be delivered, which reduces

  3. Comparison of work rates, energy expenditure, and perceived exertion during a 1-h vacuuming task with a backpack vacuum cleaner and an upright vacuum cleaner.

    PubMed

    Mengelkoch, Larry J; Clark, Kirby

    2006-03-01

    The purpose of this study was to evaluate two types of industrial vacuum cleaners, in terms of cleaning rates, energy expenditure, and perceived exertion. Twelve industrial cleaners (six males and six females, age 28-39 yr) performed two 1-h vacuuming tasks with an upright vacuum cleaner (UVC) and a backpack vacuum cleaner (BPVC). Measures for oxygen uptake (VO2) and ratings of perceived exertion (RPE) were collected continuously during the 1-h vacuuming tasks. Cleaning rates for the UVC and BPVC were 7.23 and 14.98 m2min(-1), respectively. On a separate day subjects performed a maximal treadmill exercise test to determine their maximal aerobic capacity (peak VO2). Average absolute energy costs (in Metabolic equivalents), relative energy costs of the vacuum task compared to the subjects' maximal aerobic capacity (% peak VO2), and RPE responses for the 1-h vacuuming tasks were similar between vacuum cleaners, but % peak VO2 and RPE values differed between genders. These results indicate that the BPVC was more efficient than the UVC. With the BPVC, experienced workers vacuumed at a cleaning rate 2.07 times greater than the UVC and had similar levels of energy expenditure and perceived effort, compared to the slower cleaning rate with the UVC.

  4. Implementing a routine outcome assessment procedure to evaluate the quality of assistive technology service delivery for children with physical or multiple disabilities: Perceived effectiveness, social cost, and user satisfaction.

    PubMed

    Desideri, Lorenzo; Bizzarri, Martina; Bitelli, Claudio; Roentgen, Uta; Gelderblom, Gert-Jan; de Witte, Luc

    2016-01-01

    There is a lack of evidence on the effects and quality of assistive technology service delivery (ATSD). This study presents a quasi-experimental 3-months follow-up using a pre-test/post-test design aimed at evaluating outcomes of assistive technology (AT) interventions targeting children with physical and multiple disabilities. A secondary aim was to evaluate the feasibility of the follow-up assessment adopted in this study with a view to implement the procedure in routine clinical practice. Forty-five children aged 3-17 years were included. Parents were asked to complete the Individual Prioritised Problem Assessment (IPPA) for AT effectiveness; KWAZO (Kwaliteit van Zorg [Quality of Care]) and Quebec User Evaluation of Satisfaction with Assistive Technology (QUEST) 2.0 for satisfaction with ATSD; Siva Cost Analysis Instrument (SCAI) for estimating the social cost of AT interventions. At follow-up, 25 children used the AT recommended. IPPA effect sizes ranged from 1.4 to 0.7, showing a large effect of AT interventions. Overall, parents were satisfied with ATSD, but Maintenance, Professional Services, and AT Delivery were rated not satisfactory. SCAI showed more resources spent for AT intervention compared to human assistance without technological supports. AT may be an effective intervention for children with disabilities. Issues concerning responsiveness and feasibility of the IPPA and the SCAI instruments are discussed with a view to inform routine clinical practice.

  5. A radiation hard vacuum switch

    DOEpatents

    Boettcher, G.E.

    1988-07-19

    A vacuum switch with an isolated trigger probe which is not directly connected to the switching electrodes. The vacuum switch within the plasmatron is triggered by plasma expansion initiated by the trigger probe which travels through an opening to reach the vacuum switch elements. The plasma arc created is directed by the opening to the space between the anode and cathode of the vacuum switch to cause conduction. 3 figs.

  6. Comparison of vacuum rise time, vacuum limit accuracy, and occlusion break surge of 3 new phacoemulsification systems.

    PubMed

    Han, Young Keun; Miller, Kevin M

    2009-08-01

    To compare vacuum rise time, vacuum limit accuracy, and occlusion break surge of 3 new phacoemulsification machines. Jules Stein Eye Institute and Department of Ophthalmology, David Geffen School of Medicine at UCLA, Los Angeles, California, USA. The vacuum rise time under normal and enhanced aspiration modes, vacuum limit accuracy, and occlusion break surge of the Infiniti Vision System, Stellaris Vision Enhancement System, and WhiteStar Signature Phacoemulsification System were tested. Vacuum rise time and limit accuracy were measured at limit settings of 400 mm Hg and 600 mm Hg. Surge area was recorded at vacuum limit settings of 200 mm Hg, 300 mm Hg, 400 mm Hg, and 500 mm Hg. The Infiniti had the fastest vacuum rise times under normal and enhanced aspiration modes. At 4 seconds, the vacuum limit accuracy was greatest with the Infiniti at the 400 mm Hg limit and the Signature at the 600 mm Hg limit. The Stellaris did not reach either vacuum target. The Infiniti performed better than the other 2 machines during testing of occlusion break surge at all vacuum limit settings above 200 mm Hg. Under controlled laboratory test conditions, the Infiniti had the fastest vacuum rise time, greatest vacuum limit accuracy at 400 mm Hg, and least occlusion break surge. These results can be explained by the lower compliance of the Infiniti system.

  7. Vacuum-assisted closure device as a split-thickness skin graft bolster in the burn population.

    PubMed

    Waltzman, Joshua T; Bell, Derek E

    2014-01-01

    The vacuum-assisted closure device (VAC) is associated with improved wound healing outcomes. Its use as a bolster device to secure a split-thickness skin graft has been previously demonstrated; however, there is little published evidence demonstrating its benefits specifically in the burn population. With use of the VAC becoming more commonplace, its effect on skin graft take and overall time to healing in burn patients deserves further investigation. Retrospective review of burn registry database at a high-volume level I trauma center and regional burn center during a 16-month period was performed. Patients who had a third-degree burn injury requiring a split-thickness skin graft and who received a VAC bolster were included. Data points included age, sex, burn mechanism, burn location, grafted area in square centimeters, need for repeat grafting, percent graft take, and time to complete reepithelialization. Sixty-seven patients were included in the study with a total of 88 skin graft sites secured with a VAC. Age ranged from <1 year to 84 years (average 41 years). The average grafted area was 367 ± 545 cm. The three most common were the leg, thigh, and arm (28, 15, and 12%, respectively). Average percent graft take was 99.5 ± 1.5%. Notably, no patients returned to the operating room for repeat grafting. The average time to complete reepithelialization was 16 ± 7 days. The VAC is a highly reliable and reproducible method to bolster a split-thickness skin graft in the burn population. The observed rate of zero returns to the operating room for repeat grafting was especially encouraging. Its ability to conform to contours of the body and cover large surface areas makes it especially useful in securing a graft. This method of bolstering results in decreased repeat grafting and minimal graft loss, thus decreasing morbidity compared with conventional bolster dressings.

  8. Air bearing vacuum seal assembly

    DOEpatents

    Booth, Rex

    1978-01-01

    An air bearing vacuum seal assembly capable of rotating at the speed of several thousand revolutions per minute using an air cushion to prevent the rotating and stationary parts from touching, and a two stage differential pumping arrangement to maintain the pressure gradient between the air cushion and the vacuum so that the leak rate into the vacuum is, for example, less than 1 .times. 10.sup.-4 Pa m.sup.3 /s. The air bearing vacuum seal has particular application for mounting rotating targets to an evacuated accelerator beam tube for bombardment of the targets with high-power charged particle beams in vacuum.

  9. Growth control of oxygen stoichiometry in homoepitaxial SrTiO3 films by pulsed laser epitaxy in high vacuum

    PubMed Central

    Lee, Ho Nyung; Ambrose Seo, Sung S.; Choi, Woo Seok; Rouleau, Christopher M.

    2016-01-01

    In many transition metal oxides, oxygen stoichiometry is one of the most critical parameters that plays a key role in determining the structural, physical, optical, and electrochemical properties of the material. However, controlling the growth to obtain high quality single crystal films having the right oxygen stoichiometry, especially in a high vacuum environment, has been viewed as a challenge. In this work, we show that, through proper control of the plume kinetic energy, stoichiometric crystalline films can be synthesized without generating oxygen defects even in high vacuum. We use a model homoepitaxial system of SrTiO3 (STO) thin films on single crystal STO substrates. Physical property measurements indicate that oxygen vacancy generation in high vacuum is strongly influenced by the energetics of the laser plume, and it can be controlled by proper laser beam delivery. Therefore, our finding not only provides essential insight into oxygen stoichiometry control in high vacuum for understanding the fundamental properties of STO-based thin films and heterostructures, but expands the utility of pulsed laser epitaxy of other materials as well. PMID:26823119

  10. Vacuum-Gauge Connection For Shipping Container

    NASA Technical Reports Server (NTRS)

    Henry, Robert H.

    1990-01-01

    External connector enables measurement of vacuum in stored part. Remote-readout connector added to shipping container and connected to thermo-couple vacuum gauge in vacuum-insulated cryogenic line packed in container. Enables monitoring of condition of vacuum without opening container.

  11. 320 x 240 uncooled IRFPA with pixel wise thin film vacuum packaging

    NASA Astrophysics Data System (ADS)

    Yon, J.-J.; Dumont, G.; Rabaud, W.; Becker, S.; Carle, L.; Goudon, V.; Vialle, C.; Hamelin, A.; Arnaud, A.

    2012-10-01

    Silicon based vacuum packaging is a key enabling technology for achieving affordable uncooled Infrared Focal Plane Arrays (IRFPA) as required by the promising mass market for very low cost IR applications, such as automotive driving assistance, energy loss monitoring in buildings, motion sensors… Among the various approaches studied worldwide, the CEA, LETI is developing a unique technology where each bolometer pixel is sealed under vacuum at the wafer level, using an IR transparent thin film deposition. This technology referred to as PLP (Pixel Level Packaging), leads to an array of hermetic micro-caps each containing a single microbolometer. Since the successful demonstration that the PLP technology, when applied on a single microbolometer pixel, can provide the required vacuum < 10-3 mbar, the authors have pushed forward the development of the technology on fully operational QVGA readout circuits CMOS base wafers (320 x 240 pixels). In this outlook, the article reports on the electro optical performance obtained from this preliminary PLP based QVGA demonstrator. Apart from the response, noise and NETD distributions, the paper also puts emphasis on additional key features such as thermal time constant, image quality, and ageing properties.

  12. Performance of the Satellite Test Assistant Robot in JPL's Space Simulation Facility

    NASA Technical Reports Server (NTRS)

    Mcaffee, Douglas; Long, Mark; Johnson, Ken; Siebes, Georg

    1995-01-01

    An innovative new telerobotic inspection system called STAR (the Satellite Test Assistant Robot) has been developed to assist engineers as they test new spacecraft designs in simulated space environments. STAR operates inside the ultra-cold, high-vacuum, test chambers and provides engineers seated at a remote Operator Control Station (OCS) with high resolution video and infrared (IR) images of the flight articles under test. STAR was successfully proof tested in JPL's 25-ft (7.6-m) Space Simulation Chamber where temperatures ranged from +85 C to -190 C and vacuum levels reached 5.1 x 10(exp -6) torr. STAR's IR Camera was used to thermally map the entire interior of the chamber for the first time. STAR also made several unexpected and important discoveries about the thermal processes occurring within the chamber. Using a calibrated test fixture arrayed with ten sample spacecraft materials, the IR camera was shown to produce highly accurate surface temperature data. This paper outlines STAR's design and reports on significant results from the thermal vacuum chamber test.

  13. NSLS II Vacuum System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ferreira, M.; Doom, L.; Hseuh, H.

    2009-09-13

    National Synchrotron Light Source II, being constructed at Brookhaven, is a 3-GeV, 500 mA, 3rd generation synchrotron radiation facility with ultra low emittance electron beams. The storage ring vacuum system has a circumference of 792 m and consists of over 250 vacuum chambers with a simulated average operating pressure of less than 1 x 10{sup -9} mbar. A summary of the update design of the vacuum system including girder supports of the chambers, gauges, vacuum pumps, bellows, beam position monitors and simulation of the average pressure will be shown. A brief description of the techniques and procedures for cleaning andmore » mounting the chambers are given.« less

  14. IPM Delivery and Facilitation of Innovation Through Technology - National

    Science.gov Websites

    Delivery IPM Delivery The Regional IPM Centers provide Information Systems to help facilitate communication and sharing of information related to Integrated Pest Management. Below are the various offerings that suggestions for add-ins that may assist project management. For more information, contact Joe LaForest or the

  15. Effective Porosity Measurements by Wet- and Dry-type Vacuum Saturations using Process-Programmable Vacuum Saturation System

    NASA Astrophysics Data System (ADS)

    Lee, T. J.; Lee, K. S., , Dr; Lee, S. K.

    2017-12-01

    One of the most important factors in measuring effective porosity by vacuum saturation method is that the air in the pore space can be fully substituted by water during the vacuum saturation process. International Society of Rock Mechanics (ISRM) suggests vacuuming a rock sample submerged in the water, while American Society of Test and Materials (ASTM) vacuuming the sample and water separately and then pour the water to the sample. In this study, we call the former wet-type vacuum saturation (WVS) method and the latter dry-type vacuum saturation (DVS) method, and compare the effective porosity measured by the two different vacuum saturation processes. For that purpose, a vacuum saturation system has been developed, which can support both WVS and DVS by only changing the process by programming. Comparison of effective porosity has been made for a cement mortar and rock samples. As a result, DVS can substitute more void volume to water than WVS, which in turn insists that DVS can provide more exact value of effective porosity than WVS.

  16. Does isolated flat epithelial atypia on vacuum-assisted breast core biopsy require surgical excision?

    PubMed

    Dialani, Vandana; Venkataraman, Shambhavi; Frieling, Gretchen; Schnitt, Stuart J; Mehta, Tejas S

    2014-01-01

    To determine whether flat epithelial atypia (FEA) found in isolation on large core vacuum-assisted biopsy (CNB) requires surgical excision. After Institutional Review Board approval, pathology reports of all patients who underwent CNB from January 1, 2005 to December 31, 2010 were reviewed. All patients with reports of isolated FEA without other atypia or in situ or invasive carcinoma were identified. Patient age, history, target on imaging, biopsy modality, and residual target post CNB noted. Histology of CNB's (blinded to surgical outcome) and subsequent surgical excisions were reviewed by a dedicated breast pathologist. Only cases with confirmed isolated FEA on review were used for data analysis. Of 2,556 CNB's performed over 6 years, 37 (1.4%) had isolated FEA confirmed on review, comprising our study population. Thirty (81%) had biopsy for calcifications on mammography and 7 (19%) for mass or non-mass like enhancement on magnetic resonance imaging. There were no US guided CNBs that met our inclusion criteria. 29 (78.4%) underwent surgical excision, 6 (16.2%) had imaging follow-up, and 2 (5.4%) were lost to follow-up. Of the 29 with surgery, 2 (6.9%) had "upgrade" to low-grade in situ carcinoma (1 ductal and 1 pleomorphic lobular), 5 (17.2%) had "change in diagnosis" to other atypia (ADH/ALH), 15 (51.7%) had additional FEA and 7 (24.2%) had benign tissue without atypia. Both "upgraded" cases had residual microcalcifications on imaging following CNB. There were no upgrades to invasive cancers. In our study, none of 29 with isolated FEA on CNB had invasive cancer on surgical excision. If there are residual microcalcifications or residual lesion after a CNB that shows isolated FEA, excision is warranted, due to the possibility of other atypia (ADH/ALH [17.2%] or DCIS [5.4%]). If there are no residual microcalcifications following CNB, imaging follow-up as an alternative to surgery may be a reasonable option. © 2014 Wiley Periodicals, Inc.

  17. Cryo-Vacuum Testing of the JWST Integrated Science Instrument Module

    NASA Technical Reports Server (NTRS)

    Kimble, Randy A.; Vila, M. Begona; Van Campen, Julie M.; Birkmann, Stephen M.; Comber, Brian J.; Fatig, Curtis C.; Glasse, Alistair C. H.; Glazer, Stuart D.; Kelly, Douglas M.; Mann, Steven D.; hide

    2016-01-01

    In late 2015 early 2016, a major cryo-vacuum test was carried out for the Integrated Science Instrument Module (ISIM) of the James Webb Space Telescope. This test comprised the final cryo-certification and calibration test of the ISIM before its delivery for integration with the rest of the JWST observatory. Over the roughly 100-day period of the round-the-clock test program, the full complement of ISIM flight instruments, structure, harness radiator, and electronics were put through a comprehensive program of thermal, optical, electrical, and operational tests. We briefly summarize the goals, setup, execution, and key results for this critical JWST milestone.

  18. Understanding risks of workplace injury in labor and delivery.

    PubMed

    Stichler, Jaynelle F; Feiler, Judd L; Chase, Kimberlie

    2012-01-01

    To understand nurse and other staff perceptions about care activities in labor and delivery (L&D) that were performed with high frequency, required high exertion, and had the greatest potential to cause injury and to determine what personal characteristics might be related to the caregiving tasks with potential for injury. This exploratory study employed a mixed methods design using qualitative open-ended questions and quantitative surveys administered in three different times (n = 56, 58, and 58). A 22-room L&D unit in a women's hospital with 8,500 annual deliveries. Nurses and assistive staff. High-risk tasks were classified in three categories. High-exertion tasks included (a) moving patients in labor, delivery, recovery (LDR) beds to other locations; (b) breaking delivery beds and applying stirrups; (c) assisting dependent patients with mobility in bed; and (d) pushing medical equipment and delivery carts. Awkward posture tasks during patient care included (a) listening for heart tones; (b) performing difficult vaginal exams; (c) keeping the fetal head off of the cord during cord prolapse; and (d) assisting with epidurals. Culture of safety tasks included (a) physician requests to conduct patient care tasks that put staff at risk for injury; (b) providers ignoring broken equipment in the environment; (c) responding to emergent/urgent situations without regard to self-posturing to prevent injury; and (d) holding patients' legs during delivery at the physician's direction. Several significant correlations were noted between demographic variables and high potential for risk items. This study provides the first information about the caregiving tasks L&D nurses perceive to be risky for personal injury because of their high frequency and exertion or breaches in the culture of safety. © 2011 AWHONN, the Association of Women's Health, Obsteric and Neonatal Nurses.

  19. Impact of maternal age on delivery outcomes following spontaneous labour at term.

    PubMed

    Omih, Edwin Eseoghene; Lindow, Stephen

    2016-10-01

    Pregnancy in women of advancing maternal age is linked to incrementally worsening perinatal outcome. The aim of this study is to assess the impact of maternal age on delivery outcome in women that spontaneously labour at term. This was a retrospective study of women that spontaneously labour at term. Women with singletons in spontaneous onset labour beyond 37 weeks of gestation were divided into five maternal age groups: <19 years, 20-24 years, 25-29 years, 30-34 years and >35 years by their age at delivery. The main outcome variables are augmentation of labour, caesarean section, assisted vaginal delivery, and perineal trauma, while admission of the newborn into the neonatal unit within 24 h following delivery was the secondary outcome measure. A total of 30,022 met the inclusion criteria with primiparae and multiparae accounting for 46 and 54%, respectively. Increasing age in primiparae was associated with; augmentation of labour OR 2.05 (95% CI 1.73-2.43), second degree perineal tear 1.35 (1.12-1.61), assisted vaginal delivery 1.92 (1.53-2.41) and caesarean section 4.23 (3.19-5.12). While that for multiparae; augmentation of labour OR 1.93 (1.05-3.52), perineal trauma 2.50 (1.85-3.34), assisted vaginal delivery 4.95 (91.82-13.35) and caesarean section 1.64 (1.13-2.38). The secondary outcome measure did not reach statistical significance. Increasing maternal age is an independent risk factor for operative delivery, and perineal trauma. However, maternal age has no significant effect on admission of infants into the NICU during the first 24 h following delivery.

  20. Multipurpose Vacuum Induction Processing System

    NASA Astrophysics Data System (ADS)

    Govindaraju, M.; Kulkarni, Deepak; Balasubramanian, K.

    2012-11-01

    Multipurpose vacuum processing systems are cost effective; occupy less space, multiple functional under one roof and user friendly. A multipurpose vacuum induction system was designed, fabricated and installed in a record time of 6 months time at NFTDC Hyderabad. It was designed to function as a) vacuum induction melting/refining of oxygen free electronic copper/pure metals, b) vacuum induction melting furnace for ferrous materials c) vacuum induction melting for non ferrous materials d) large vacuum heat treatment chamber by resistance heating (by detachable coil and hot zone) e) bottom discharge vacuum induction melting system for non ferrous materials f) Induction heat treatment system and g) directional solidification /investment casting. It contains provision for future capacity addition. The attachments require to manufacture multiple shaped castings and continuous rod casting can be added whenever need arises. Present capacity is decided on the requirement for 10years of development path; presently it has 1.2 ton liquid copper handling capacity. It is equipped with provision for capacity addition up to 2 ton liquid copper handling capacity in future. Provision is made to carry out the capacity addition in easy steps quickly. For easy operational maintenance and troubleshooting, design was made in easily detachable sections. High vacuum system is also is detachable, independent and easily movable which is first of its kind in the country. Detailed design parameters, advantages and development history are presented in this paper.

  1. Vacuum leak detector and method

    DOEpatents

    Edwards, Jr., David

    1983-01-01

    Apparatus and method for detecting leakage in a vacuum system involves a moisture trap chamber connected to the vacuum system and to a pressure gauge. Moisture in the trap chamber is captured by freezing or by a moisture adsorbent to reduce the residual water vapor pressure therein to a negligible amount. The pressure gauge is then read to determine whether the vacuum system is leaky. By directing a stream of carbon dioxide or helium at potentially leaky parts of the vacuum system, the apparatus can be used with supplemental means to locate leaks.

  2. Robot design for a vacuum environment

    NASA Technical Reports Server (NTRS)

    Belinski, S.; Trento, W.; Imani-Shikhabadi, R.; Hackwood, S.

    1987-01-01

    The cleanliness requirements for many processing and manufacturing tasks are becoming ever stricter, resulting in a greater interest in the vacuum environment. Researchers discuss the importance of this special environment, and the development of robots which are physically and functionally suited to vacuum processing tasks. Work is in progress at the Center for robotic Systems in Microelectronics (CRSM) to provide a robot for the manufacture of a revolutionary new gyroscope in high vacuum. The need for vacuum in this and other processes is discussed as well as the requirements for a vacuum-compatible robot. Finally, researchers present details on work done at the CRSM to modify an existing clean-room compatible robot for use at high vacuum.

  3. Bakeout Chamber Within Vacuum Chamber

    NASA Technical Reports Server (NTRS)

    Taylor, Daniel M.; Soules, David M.; Barengoltz, Jack B.

    1995-01-01

    Vacuum-bakeout apparatus for decontaminating and measuring outgassing from pieces of equipment constructed by mounting bakeout chamber within conventional vacuum chamber. Upgrade cost effective: fabrication and installation of bakeout chamber simple, installation performed quickly and without major changes in older vacuum chamber, and provides quantitative data on outgassing from pieces of equipment placed in bakeout chamber.

  4. Large-aperture plasma-assisted deposition of inertial confinement fusion laser coatings.

    PubMed

    Oliver, James B; Kupinski, Pete; Rigatti, Amy L; Schmid, Ansgar W; Lambropoulos, John C; Papernov, Semyon; Kozlov, Alexei; Spaulding, John; Sadowski, Daniel; Chrzan, Z Roman; Hand, Robert D; Gibson, Desmond R; Brinkley, Ian; Placido, Frank

    2011-03-20

    Plasma-assisted electron-beam evaporation leads to changes in the crystallinity, density, and stresses of thin films. A dual-source plasma system provides stress control of large-aperture, high-fluence coatings used in vacuum for substrates 1m in aperture.

  5. Vacuum infusion method for woven carbon/Kevlar reinforced hybrid composite

    NASA Astrophysics Data System (ADS)

    Hashim, N.; Majid, D. L.; Uda, N.; Zahari, R.; Yidris, N.

    2017-12-01

    The vacuum assisted resin transfer moulding (VaRTM) or Vacuum Infusion (VI) is one of the fabrication methods used for composite materials. Compared to other methods, this process costs lower than using prepregs because it does not need to use the autoclave to cure. Moreover, composites fabricated using this VI method exhibit superior mechanical properties than those made through hand layup process. In this study, the VI method is used in fabricating woven carbon/Kevlar fibre cloth with epoxy matrix. This paper reports the detailed methods on fabricating the hybrid composite using VI process and several precautions that need to be taken to avoid any damage to the properties of the composite material. The result highlights that the successfully fabricated composite has approximately 60% of fibres weight fraction. Since the composites produced by the VI process have a higher fibre percentage, this process should be considered for composites used in applications that are susceptible to the conditions where the fibres need to be the dominant element such as in tension loading.

  6. Development of Subischial Prosthetic Sockets with Vacuum-Assisted Suspension for Highly Active Persons with Transfemoral Amputations

    DTIC Science & Technology

    2015-10-01

    2011;92:1570– 1575 . 12. Ferraro C. Outcomes study of transtibial amputees using elevated vacuum suspension in comparison with pin suspension. J Prosthet...Amputees: Effect on Fit, Activity, and Limb Volume,” Arch. Phys. Med. Rehabil., 92(10), pp. 1570– 1575 . [6] Hoskins, R. D., Sutton, E. E., Kinor, D

  7. Preterm birth by vacuum extraction and neonatal outcome: a population-based cohort study.

    PubMed

    Åberg, Katarina; Norman, Mikael; Ekéus, Cecilia

    2014-01-22

    Very few studies have investigated the neonatal outcomes after vacuum extraction delivery (VE) in the preterm period and the results of these studies are inconclusive. The objective of this study was to describe the use of VE for preterm delivery in Sweden and to compare rates of neonatal complications after preterm delivery by VE to those found after cesarean section during labor (CS) or unassisted vaginal delivery (VD). Data was obtained from Swedish national registers. In a population-based cohort from 1999 to 2010, all live-born, singleton preterm infants in a non-breech presentation at birth, born after onset of labor (either spontaneously, by induction, or by rupture of membranes) by VD, CS, or VE were included, leaving a study population of 40,764 infants. Logistic regression analyses were used to calculate adjusted odds ratios (AOR), using unassisted vaginal delivery as reference group. VE was used in 5.7% of the preterm deliveries, with lower rates in earlier gestations. Overall, intracranial hemorrhage (ICH) occurred in 1.51%, extracranial hemorrhage (ECH) in 0.64%, and brachial plexus injury in 0.13% of infants. Infants delivered by VE had higher risks for ICH (AOR = 1.84 (95% CI: 1.09-3.12)), ECH (AOR = 4.48 (95% CI: 2.84-7.07)) and brachial plexus injury (AOR = 6.21 (95% CI: 2.22-17.4)), while infants delivered by CS during labor had no increased risk for these complications, as compared to VD. While rates of neonatal complications after VE are generally low, higher odds ratios for intra- and extracranial hemorrhages and brachial plexus injuries after VE, compared with other modes of delivery, support a continued cautious use of VE for preterm delivery.

  8. Growth control of oxygen stoichiometry in homoepitaxial SrTiO 3 films by pulsed laser epitaxy in high vacuum

    DOE PAGES

    Lee, Ho Nyung; Ambrose Seo, Sung S.; Choi, Woo Seok; ...

    2016-01-29

    In many transition metal oxides, oxygen stoichiometry is one of the most critical parameters that plays a key role in determining the structural, physical, optical, and electrochemical properties of the material. However, controlling the growth to obtain high quality single crystal films having the right oxygen stoichiometry, especially in a high vacuum environment, has been viewed as a challenge. In this work, we show that, through proper control of the plume kinetic energy, stoichiometric crystalline films can be synthesized without generating oxygen defects even in high vacuum. We use a model homoepitaxial system of SrTiO 3 (STO) thin films onmore » single crystal STO substrates. Physical property measurements indicate that oxygen vacancy generation in high vacuum is strongly influenced by the energetics of the laser plume, and it can be controlled by proper laser beam delivery. Thus, our finding not only provides essential insight into oxygen stoichiometry control in high vacuum for understanding the fundamental properties of STO-based thin films and heterostructures, but it expands the utility of pulsed laser epitaxy of other materials as well.₃« less

  9. Laser-assisted delivery of vitamin C, vitamin E, and ferulic acid formula serum decreases fractional laser postoperative recovery by increased beta fibroblast growth factor expression.

    PubMed

    Waibel, Jill S; Mi, Qing-Sheng; Ozog, David; Qu, Le; Zhou, Li; Rudnick, Ashley; Al-Niaimi, Firas; Woodward, Julie; Campos, Valerie; Mordon, Serge

    2016-03-01

    Laser-assisted drug delivery is an emerging technology to achieve greater penetration by existing topical medications to reach desired targets in the tissue. The objective of this research was to study whether laser-assisted delivery of Vitamin C, E, and Ferulic immediately postoperatively of fractional ablative laser could improve wound healing. Secondary objectives were to evaluate the potential molecular markers involved in this wound-healing process. A double blinded, prospective, single center, randomized split face trial of Vitamin C, E, and Ferulic topical formula #740019 to decrease postoperative recovery time in fractional ablative laser resurfacing for photo damage. Fifteen healthy men and women of ages 30-55 years were treated with the Vitamin C, E, and Ferulic acid serum to one side of face and vehicle to the other side of face, within 2 minutes immediately after fractional ablative CO2 laser surgery and daily during the healing process. Patients were evaluated daily on days 1-7 using photographs, patient questionnaires, and molecular evaluation. Clinically, postoperative Vitamin C, E, and Ferulic delivery resulted in decreased edema versus vehicle on postoperative day 7 and decreased erythema versus vehicle on postoperative days 3 and 5. Molecularly, the expression of basic fibroblast growth factor (bFGF) was significantly increased at day 5 on the lesion treated with Vitamin C, E, and Ferulic acid serum compared to vehicle control on the other side. This is first study to show that Vitamin C, E, and Ferulic acid correlate with more rapid wound healing post-fractional ablative laser. Elevated bFGF could be involved in the Vitamin C, E, and Ferulic acid-induced rapid wound healing. © 2015 Wiley Periodicals, Inc.

  10. Faster extraction of heavy metals from soils using vacuum and ultrasonic energy.

    PubMed

    Pontes, Fernanda V M; Carneiro, Manuel C; de da Souza, Evelyn M F; da Silva, Lílian I D; Monteiro, Maria Inês C; Neto, Arnaldo A

    2013-01-01

    A fast vacuum- and ultrasound-assisted acid extraction of Co, Cu, Fe, Mn, Pb, and Zn from soils using a homemade system has been investigated. Preliminarily, a full factorial design with two levels and three variables (extracting agent, extraction temperature, and sonication time) was applied to optimize the extraction conditions (without vacuum) for some heavy metals (Cu, Mn, Pb, and Zn). The best results were obtained with a 3:1 HCI extraction solution, temperature of 80 degrees C, and time of 2 h. As this sonication time was too long, a vacuum pump was used to produce air bubbles in order to increase the contact between the sample and the extracting agent and to prevent the sample sedimentation. This improvement drastically reduced the sonication time to 2 min. Under these conditions, Co, Cu, Mn, and Zn were totally extracted (recoveries of 86-99%), while recoveries of 73-76 and 74% were obtained for Fe and Pb, respectively. The LOD values using flame atomic absorption spectrometry for determination of Co, Cu, Fe, Mn, Pb, and Zn were 3.2, 7.5, 37.5, 7.5, 22.5, and 3.8 micro glg, respectively. The RSDs were lower than 11% (n = 3).

  11. Improving Vacuum Cleaners

    NASA Technical Reports Server (NTRS)

    1997-01-01

    Under a Space Act Agreement between the Kirby company and Lewis Research Center, NASA technology was applied to a commercial vacuum cleaner product line. Kirby engineers were interested in advanced operational concepts, such as particle flow behavior and vibration, critical factors to improve vacuum cleaner performance. An evaluation of the company 1994 home care system, the Kirby G4, led to the refinement of the new G5 and future models. Under the cooperative agreement, Kirby had access to Lewis' holography equipment, which added insight into how long a vacuum cleaner fan would perform, as well as advanced computer software that can simulate the flow of air through fans. The collaboration resulted in several successes including fan blade redesign and continuing dialogue on how to improve air-flow traits in various nozzle designs.

  12. Inequality of the use of skilled birth assistance among rural women in Bangladesh: facts and factors.

    PubMed

    Kamal, S M Mostafa; Hassan, Che Hashim; Kabir, M A

    2015-03-01

    This study examines the inequality of the use of skilled delivery assistance by the rural women of Bangladesh using the 2007 Bangladesh Demographic and Health Survey data. Simple cross-tabulation and univariate and multivariate statistical analyses were employed in the study. Overall, 56.1% of the women received at least one antenatal care visit, whereas only 13.2% births were assisted by skilled personnel. Findings revealed apparent inequality in using skilled delivery assistance by socioeconomic strata. Birth order, women's education, religion, wealth index, region and antenatal care are important determinants of seeking skilled assistance. To ensure safe motherhood initiative, government should pay special attention to reduce inequality in seeking skilled delivery assistance. A strong focus on community-based and regional interventions is important in order to increase the utilization of safe maternal health care services in rural Bangladesh. © 2013 APJPH.

  13. Switching Circuit for Shop Vacuum System

    NASA Technical Reports Server (NTRS)

    Burley, R. K.

    1987-01-01

    No internal connections to machine tools required. Switching circuit controls vacuum system draws debris from grinders and sanders in machine shop. Circuit automatically turns on vacuum system whenever at least one sander or grinder operating. Debris safely removed, even when operator neglects to turn on vacuum system manually. Pickup coils sense alternating magnetic fields just outside operating machines. Signal from any coil or combination of coils causes vacuum system to be turned on.

  14. Vacuum Brazing of Accelerator Components

    NASA Astrophysics Data System (ADS)

    Singh, Rajvir; Pant, K. K.; Lal, Shankar; Yadav, D. P.; Garg, S. R.; Raghuvanshi, V. K.; Mundra, G.

    2012-11-01

    Commonly used materials for accelerator components are those which are vacuum compatible and thermally conductive. Stainless steel, aluminum and copper are common among them. Stainless steel is a poor heat conductor and not very common in use where good thermal conductivity is required. Aluminum and copper and their alloys meet the above requirements and are frequently used for the above purpose. The accelerator components made of aluminum and its alloys using welding process have become a common practice now a days. It is mandatory to use copper and its other grades in RF devices required for accelerators. Beam line and Front End components of the accelerators are fabricated from stainless steel and OFHC copper. Fabrication of components made of copper using welding process is very difficult and in most of the cases it is impossible. Fabrication and joining in such cases is possible using brazing process especially under vacuum and inert gas atmosphere. Several accelerator components have been vacuum brazed for Indus projects at Raja Ramanna Centre for Advanced Technology (RRCAT), Indore using vacuum brazing facility available at RRCAT, Indore. This paper presents details regarding development of the above mentioned high value and strategic components/assemblies. It will include basics required for vacuum brazing, details of vacuum brazing facility, joint design, fixturing of the jobs, selection of filler alloys, optimization of brazing parameters so as to obtain high quality brazed joints, brief description of vacuum brazed accelerator components etc.

  15. Effects of Acculturation on Assistive Technology Service Delivery

    ERIC Educational Resources Information Center

    Parette, Howard P.; Huer, Mary Blake; Scherer, Marcia

    2004-01-01

    Given the increasing number of students with disabilities from diverse cultural backgrounds who are being served in special education settings (Harry, 1992), professionals have begun to focus attention on processes and strategies for ensuring culturally sensitive assistive technology (AT) decision-making (Parette, Huer, & VanBiervliet, in press;…

  16. Flat epithelial atypia: conservative management of patients without residual microcalcifications post-vacuum-assisted breast biopsy.

    PubMed

    Schiaffino, Simone; Gristina, Licia; Villa, Alessandro; Tosto, Simona; Monetti, Francesco; Carli, Franca; Calabrese, Massimo

    2018-01-01

    To determine the malignancy rate (defined in this study as stability or absence of malignancy developed on close imaging follow-up post-biopsy) of conservative management in patients with a vacuum-assisted breast biopsy (VAB) diagnosis of flat epithelial atypia (FEA), performed on single group of microcalcifications, completely removed during procedure. This is a retrospective, monocentric, observational study, approved by IRB. Inclusion criteria were: VAB performed on a single group of microcalcifications; the absence of residual calcifications post-VAB; diagnosis of isolated FEA as the most advanced proliferative lesion; radiological follow-up at least of 12 months. The personal history of breast cancer or other high-risk lesions was an exclusion criteria. The patients enrolled were conservatively managed, without surgical excision, through close follow-up: the first two mammographies performed with an interval of 6 months after biopsy, followed by annual mammographic and clinical checks. 48 consecutive patients were enrolled in the study, all females, with age range of 39-76 years (mean 53,3 years) and radiological follow-up range of 13-75 months (mean 41.5 months). All the lesions were classified as BI-RADS 4b. The diameter range of the group of calcifications was 3-10 mm (mean 5, 6 mm). In each patient, 7 to 15 samples (mean 11) were obtained. Among all the patients, there was only one case (2%) of new microcalcifications, developed in the same breast, 26 months after and 8 mm from the site of previous VAB, and interpreted as ADH at surgical excision. All the checks of the other patients were negative. Even with a limited follow-up, we found a malignancy rate lower than 2%, through a defined population. Further studies with bigger number of patients and extended follow-up are needed to reinforce this hypothesis. Advances in knowledge: Surgical excision may not be necessary in patients with VAB diagnosis of isolated FEA, without residual

  17. Investigation of Dielectric Breakdown Characteristics for Double-break Vacuum Interrupter and Dielectric Breakdown Probability Distribution in Vacuum Interrupter

    NASA Astrophysics Data System (ADS)

    Shioiri, Tetsu; Asari, Naoki; Sato, Junichi; Sasage, Kosuke; Yokokura, Kunio; Homma, Mitsutaka; Suzuki, Katsumi

    To investigate the reliability of equipment of vacuum insulation, a study was carried out to clarify breakdown probability distributions in vacuum gap. Further, a double-break vacuum circuit breaker was investigated for breakdown probability distribution. The test results show that the breakdown probability distribution of the vacuum gap can be represented by a Weibull distribution using a location parameter, which shows the voltage that permits a zero breakdown probability. The location parameter obtained from Weibull plot depends on electrode area. The shape parameter obtained from Weibull plot of vacuum gap was 10∼14, and is constant irrespective non-uniform field factor. The breakdown probability distribution after no-load switching can be represented by Weibull distribution using a location parameter. The shape parameter after no-load switching was 6∼8.5, and is constant, irrespective of gap length. This indicates that the scatter of breakdown voltage was increased by no-load switching. If the vacuum circuit breaker uses a double break, breakdown probability at low voltage becomes lower than single-break probability. Although potential distribution is a concern in the double-break vacuum cuicuit breaker, its insulation reliability is better than that of the single-break vacuum interrupter even if the bias of the vacuum interrupter's sharing voltage is taken into account.

  18. Vacuum-insulated catalytic converter

    DOEpatents

    Benson, David K.

    2001-01-01

    A catalytic converter has an inner canister that contains catalyst-coated substrates and an outer canister that encloses an annular, variable vacuum insulation chamber surrounding the inner canister. An annular tank containing phase-change material for heat storage and release is positioned in the variable vacuum insulation chamber a distance spaced part from the inner canister. A reversible hydrogen getter in the variable vacuum insulation chamber, preferably on a surface of the heat storage tank, releases hydrogen into the variable vacuum insulation chamber to conduct heat when the phase-change material is hot and absorbs the hydrogen to limit heat transfer to radiation when the phase-change material is cool. A porous zeolite trap in the inner canister absorbs and retains hydrocarbons from the exhaust gases when the catalyst-coated substrates and zeolite trap are cold and releases the hydrocarbons for reaction on the catalyst-coated substrate when the zeolite trap and catalyst-coated substrate get hot.

  19. Vacuum-Induction, Vacuum-Arc, and Air-Induction Melting of a Complex Heat-Resistant Alloy

    NASA Technical Reports Server (NTRS)

    Decker, R. F.; Rowe, John P.; Freeman, J. W.

    1959-01-01

    The relative hot-workability and creep-rupture properties at 1600 F of a complex 55Ni-20Cr-15Co-4Mo-3Ti-3Al alloy were evaluated for vacuum-induction, vacuum-arc, and air-induction melting. A limited study of the role of oxygen and nitrogen and the structural effects in the alloy associated with the melting process was carried out. The results showed that the level of boron and/or zirconium was far more influential on properties than the melting method. Vacuum melting did reduce corner cracking and improve surface during hot-rolling. It also resulted in more uniform properties within heats. The creep-rupture properties were slightly superior in vacuum heats at low boron plus zirconium or in heats with zirconium. There was little advantage at high boron levels and air heats were superior at high levels of boron plus zirconium. Vacuum heats also had fewer oxide and carbonitride inclusions although this was a function of the opportunity for separation of the inclusions from high oxygen plus nitrogen heats. The removal of phosphorous by vacuum melting was not found to be related to properties. Oxygen plus nitrogen appeared to increase ductility in creep-rupture tests suggesting that vacuum melting removes unidentified elements detrimental to ductility. Oxides and carbonitrides in themselves did not initiate microcracks. Carbonitrides in the grain boundaries of air heats did initiate microcracks. The role of microcracking from this source and as a function of oxygen and nitrogen content was not clear. Oxygen and nitrogen did intensify corner cracking during hot-rolling but were not responsible for poor surface which resulted from rolling heats melted in air.

  20. Delivery of Health Coaching by Medical Assistants in Primary Care.

    PubMed

    Djuric, Zora; Segar, Michelle; Orizondo, Carissa; Mann, Jeffrey; Faison, Maya; Peddireddy, Nithin; Paletta, Matthew; Locke, Amy

    2017-01-01

    Health coaching is potentially a practical method to assist patients in achieving and maintaining healthy lifestyles. In health coaching, the coach partners with the patient, helping patients discover their own strengths, challenges, and solutions. Two medical assistants were provided with brief training. The 12-week program consisted of telephone coaching with in-person visits at the beginning and end of the program. Coaching targeted improvements in diet, physical activity, and/or sleep habits using a self-care planning form. A total of 82 subjects enrolled in the program, 72% completed 8 weeks and 49% completed 12 weeks. Subjects who completed assessments at 12 weeks had significant weight loss despite the fact that weight loss was not a study goal. There also were improvements in diet and physical activity. Subject who completed the study were highly satisfied with the program and felt that health coaching should be available in all family medicine clinics. The main barrier providers voiced was remembering to refer patients. The medical providers indicated high satisfaction with the study and valued having coaching available for their patients. Medical assistants can be trained to assist patients with lifestyle changes that are associated with improved health and weight control. © Copyright 2017 by the American Board of Family Medicine.

  1. Delivery of Health Coaching by Medical Assistants in Primary Care

    PubMed Central

    Djuric, Zora; Segar, Michelle; Orizondo, Carissa; Mann, Jeffrey; Faison, Maya; Peddireddy, Nithin; Paletta, Matthew; Locke, Amy

    2017-01-01

    Background Health coaching is potentially a practical method to assist patients in achieving and maintaining healthy lifestyles. In health coaching, the coach partners with the patient, helping patients discover their own strengths, challenges, and solutions. Methods Two medical assistants were provided with brief training. The 12-week program consisted of telephone coaching with in-person visits at the beginning and end of the program. Coaching targeted improvements in diet, physical activity, and/or sleep habits using a self-care planning form. Results A total of 82 subjects enrolled in the program, 72% completed 8 weeks and 49% completed 12 weeks. Subjects who completed assessments at 12 weeks had significant weight loss despite the fact that weight loss was not a study goal. There also were improvements in diet and physical activity. Subject who completed the study were highly satisfied with the program and felt that health coaching should be available in all family medicine clinics. The main barrier providers voiced was remembering to refer patients. The medical providers indicated high satisfaction with the study and valued having coaching available for their patients. Conclusions Medical assistants can be trained to assist patients with lifestyle changes that are associated with improved health and weight control. PMID:28484068

  2. 49 CFR 33.44 - Instances where assistance may not be provided.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... AND ALLOCATION SYSTEM Special Priorities Assistance § 33.44 Instances where assistance may not be... attempting to: (a) Secure a price advantage; (b) Obtain delivery prior to the time required to fill a rated...

  3. 49 CFR 33.44 - Instances where assistance may not be provided.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... AND ALLOCATION SYSTEM Special Priorities Assistance § 33.44 Instances where assistance may not be... attempting to: (a) Secure a price advantage; (b) Obtain delivery prior to the time required to fill a rated...

  4. 49 CFR 33.44 - Instances where assistance may not be provided.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... AND ALLOCATION SYSTEM Special Priorities Assistance § 33.44 Instances where assistance may not be... attempting to: (a) Secure a price advantage; (b) Obtain delivery prior to the time required to fill a rated...

  5. Cationic lipid-assisted polymeric nanoparticle mediated GATA2 siRNA delivery for synthetic lethal therapy of KRAS mutant non-small-cell lung carcinoma.

    PubMed

    Shen, Song; Mao, Chong-Qiong; Yang, Xian-Zhu; Du, Xiao-Jiao; Liu, Yang; Zhu, Yan-Hua; Wang, Jun

    2014-08-04

    Synthetic lethal interaction provides a conceptual framework for the development of wiser cancer therapeutics. In this study, we exploited a therapeutic strategy based on the interaction between GATA binding protein 2 (GATA2) downregulation and the KRAS mutation status by delivering small interfering RNA targeting GATA2 (siGATA2) with cationic lipid-assisted polymeric nanoparticles for treatment of non-small-cell lung carcinoma (NSCLC) harboring oncogenic KRAS mutations. Nanoparticles carrying siGATA2 (NPsiGATA2) were effectively taken up by NSCLC cells and resulted in targeted gene suppression. NPsiGATA2 selectively inhibited cell proliferation and induced cell apoptosis in KRAS mutant NSCLC cells. However, this intervention was harmless to normal KRAS wild-type NSCLC cells and HL7702 hepatocytes, confirming the advantage of synthetic lethality-based therapy. Moreover, systemic delivery of NPsiGATA2 significantly inhibited tumor growth in the KRAS mutant A549 NSCLC xenograft murine model, suggesting the therapeutic promise of NPsiGATA2 delivery in KRAS mutant NSCLC therapy.

  6. Convergence of anatomy, technology, and therapeutics: a review of laser-assisted drug delivers.

    PubMed

    Brauer, Jeremy A; Krakowski, Andrew C; Bloom, Bradley S; Nguyen, Tuyet A; Geronemus, Roy G

    2014-12-01

    This is a very exciting time in cutaneous laser surgery with an ever-expanding therapeutic armamentarium and an increased sophistication of available technology. These recent trends have allowed for both a rapid development of interest and exploration of laser-assisted drug delivery and its potential applications. We review the current literature on anatomy, technology, and therapeutics as it relates to laser-assisted drug delivery. The focus of our review is on two areas of interest that have received much attention to date - photodynamic therapy in the treatment of actinic keratoses and nonmelanoma skin cancers as well as the treatment of scarring. We will also discuss potential complications of existing modalities used independently and in laser-assisted drug delivery and conclude with future indications for this burgeoning therapeutic methodology.

  7. Use of a home vacuum-assisted closure device in the burn population is both cost-effective and efficacious.

    PubMed

    Mushin, Oren P; Bogue, Jarrod T; Esquenazi, Mica D; Toscano, Nicole; Bell, Derek E

    2017-05-01

    The vacuum assisted closure device (VAC) improves wound-healing when utilized as a bolster to secure split thickness skin grafts (STSG). Patients typically remain hospitalized for VAC therapy; however, home VACs (hVAC) are now available. Limited studies examine burns treated with hVAC as a STSG bolster. A retrospective study of records from an ABA verified regional burn center was conducted over 23 months. Patients included STSGs for burn. Data points included demographics, burn mechanism and location, graft characteristics, hospital length of stay (LOS), and time to heal. Fifty patients were included, with average age of 39 years (range <1-83years). Average burn TBSA was 1.27±1.42 (range 0.05-8.18). Grafted area average was 102.9±128.1cm 2 . The most commonly treated areas were the leg/foot, thigh, and torso (53%, 16%, and 16%, respectively). Average LOS was 1.1±1.2 days. Mean graft-take was 99.2±2.8% with one patient undergoing repeat STSG. Average post-operative time to heal was 16±6 days. A 5-day inpatient stay with a VAC costs an average of $34,635, compared to $9134 for an hVAC over the same period. The hVAC is a cost-effective STSG bolster in the burn population for appropriate candidates. Excellent graft-take and low morbidity rates imply that this is an efficacious alternative for STSG bolster. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  8. The effect of vacuum assisted socket suspension on prospective, community-based falls by users of lower limb prostheses.

    PubMed

    Rosenblatt, Noah J; Ehrhardt, Tess

    2017-06-01

    Individuals with lower limb amputation are at increased risk of falling compared to age-matched peers. The purpose of this study was to quantify the effect of socket suspension on the risk of falling, by comparing prospectively tracked falls between a group of participants that used vacuum assisted socket suspension (VASS) and a group that did not use this system. Fifteen current users of VASS and 12 non-VASS users received an email every two weeks for one year, with a link to an online survey that asked whether they fell (i.e., "unintentionally came to rest on a lower surface") or stumbled (i.e., lost balance but did not fall) in the prior two weeks. A Chi-squared test was used to compare fall and stumble risk between groups, after stratifying by level of amputation, and the phi coefficient (φ) was used to quantify effect size. While the use of VASS did not affect the rate of falling (i.e., falls per person year) for either persons with transtibial amputation (TTA) or those with transfemoral amputation (TFA), the absolute risk of having multiple falls was reduced by nearly 75% in the former (φ=0.83), which is particularly important given that recurrent falls are associated with more severe injuries. There was no effect of VASS on the risk of falls in TFA. Further work is warranted to demonstrate the persistence of these effects in larger, more controlled samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Running vacuum cosmological models: linear scalar perturbations

    NASA Astrophysics Data System (ADS)

    Perico, E. L. D.; Tamayo, D. A.

    2017-08-01

    In cosmology, phenomenologically motivated expressions for running vacuum are commonly parameterized as linear functions typically denoted by Λ(H2) or Λ(R). Such models assume an equation of state for the vacuum given by bar PΛ = - bar rhoΛ, relating its background pressure bar PΛ with its mean energy density bar rhoΛ ≡ Λ/8πG. This equation of state suggests that the vacuum dynamics is due to an interaction with the matter content of the universe. Most of the approaches studying the observational impact of these models only consider the interaction between the vacuum and the transient dominant matter component of the universe. We extend such models by assuming that the running vacuum is the sum of independent contributions, namely bar rhoΛ = Σibar rhoΛi. Each Λ i vacuum component is associated and interacting with one of the i matter components in both the background and perturbation levels. We derive the evolution equations for the linear scalar vacuum and matter perturbations in those two scenarios, and identify the running vacuum imprints on the cosmic microwave background anisotropies as well as on the matter power spectrum. In the Λ(H2) scenario the vacuum is coupled with every matter component, whereas the Λ(R) description only leads to a coupling between vacuum and non-relativistic matter, producing different effects on the matter power spectrum.

  10. Solid state perovskite solar modules by vacuum-vapor assisted sequential deposition on Nd:YVO₄ laser patterned rutile TiO₂ nanorods.

    PubMed

    Fakharuddin, Azhar; Palma, Alessandro L; Di Giacomo, Francesco; Casaluci, Simone; Matteocci, Fabio; Wali, Qamar; Rauf, Muhammad; Di Carlo, Aldo; Brown, Thomas M; Jose, Rajan

    2015-12-11

    The past few years have witnessed remarkable progress in solution-processed methylammonium lead halide (CH3NH3PbX3, X = halide) perovskite solar cells (PSCs) with reported photoconversion efficiency (η) exceeding 20% in laboratory-scale devices and reaching up to 13% in their large area perovskite solar modules (PSMs). These devices mostly employ mesoporous TiO2 nanoparticles (NPs) as an electron transport layer (ETL) which provides a scaffold on which the perovskite semiconductor can grow. However, limitations exist which are due to trap-limited electron transport and non-complete pore filling. Herein, we have employed TiO2 nanorods (NRs), a material offering a two-fold higher electronic mobility and higher pore-filing compared to their particle analogues, as an ETL. A crucial issue in NRs' patterning over substrates is resolved by using precise Nd:YVO4 laser ablation, and a champion device with η ∼ 8.1% is reported via a simple and low cost vacuum-vapor assisted sequential processing (V-VASP) of a CH3NH3PbI3 film. Our experiments showed a successful demonstration of NRs-based PSMs via the V-VASP technique which can be applied to fabricate large area modules with a pin-hole free, smooth and dense perovskite layer which is required to build high efficiency devices.

  11. Vacuum Technology Considerations For Mass Metrology

    PubMed Central

    Abbott, Patrick J.; Jabour, Zeina J.

    2011-01-01

    Vacuum weighing of mass artifacts eliminates the necessity of air buoyancy correction and its contribution to the measurement uncertainty. Vacuum weighing is also an important process in the experiments currently underway for the redefinition of the SI mass unit, the kilogram. Creating the optimum vacuum environment for mass metrology requires careful design and selection of construction materials, plumbing components, pumping, and pressure gauging technologies. We review the vacuum technology1 required for mass metrology and suggest procedures and hardware for successful and reproducible operation. PMID:26989593

  12. A clinical review of infected wound treatment with Vacuum Assisted Closure (V.A.C.) therapy: experience and case series.

    PubMed

    Gabriel, Allen; Shores, Jaimie; Bernstein, Brent; de Leon, Jean; Kamepalli, Ravi; Wolvos, Tom; Baharestani, Mona M; Gupta, Subhas

    2009-10-01

    Over the last decade Vacuum Assisted Closure((R)) (KCI Licensing, Inc., San Antonio, TX) has been established as an effective wound care modality for managing complex acute and chronic wounds. The therapy has been widely adopted by many institutions to treat a variety of wound types. Increasingly, the therapy is being used to manage infected and critically colonized, difficult-to-treat wounds. This growing interest coupled with practitioner uncertainty in using the therapy in the presence of infection prompted the convening of an interprofessional expert advisory panel to determine appropriate use of the different modalities of negative pressure wound therapy (NPWT) as delivered by V.A.C.((R)) Therapy and V.A.C. Instill((R)) with either GranuFoam() or GranuFoam Silver() Dressings. The panel reviewed infected wound treatment methods within the context of evidence-based medicine coupled with experiential insight using V.A.C.((R)) Therapy Systems to manage a variety of infected wounds. The primary objectives of the panel were 1) to exchange state-of-practice evidence, 2) to review and evaluate the strength of existing data, and 3) to develop practice recommendations based on published evidence and clinical experience regarding use of the V.A.C.((R)) Therapy Systems in infected wounds. These recommendations are meant to identify which infected wounds will benefit from the most appropriate V.A.C.((R)) Therapy System modality and provide an infected wound treatment algorithm that may lead to a better understanding of optimal treatment strategies.

  13. Vacuum compatible sample positioning device for matrix assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aizikov, Konstantin; Lin, Tzu-Yung; Department of Electrical and Computer Engineering, Boston University, Boston, Massachusetts 02215

    The high mass accuracy and resolving power of Fourier transform ion cyclotron resonance mass spectrometers (FT-ICR MS) make them ideal mass detectors for mass spectrometry imaging (MSI), promising to provide unmatched molecular resolution capabilities. The intrinsic low tolerance of FT-ICR MS to RF interference, however, along with typically vertical positioning of the sample, and MSI acquisition speed requirements present numerous engineering challenges in creating robotics capable of achieving the spatial resolution to match. This work discusses a two-dimensional positioning stage designed to address these issues. The stage is capable of operating in {approx}1 x 10{sup -8} mbar vacuum. The rangemore » of motion is set to 100 mm x 100 mm to accommodate large samples, while the positioning accuracy is demonstrated to be less than 0.4 micron in both directions under vertical load over the entire range. This device was integrated into three different matrix assisted laser desorption/ionization (MALDI) FT-ICR instruments and showed no detectable RF noise. The ''oversampling'' MALDI-MSI experiments, under which the sample is completely ablated at each position, followed by the target movement of the distance smaller than the laser beam, conducted on the custom-built 7T FT-ICR MS demonstrate the stability and positional accuracy of the stage robotics which delivers high spatial resolution mass spectral images at a fraction of the laser spot diameter.« less

  14. Gas propagation in a liquid helium cooled vacuum tube following a sudden vacuum loss

    NASA Astrophysics Data System (ADS)

    Dhuley, Ram C.

    This dissertation describes the propagation of near atmospheric nitrogen gas that rushes into a liquid helium cooled vacuum tube after the tube suddenly loses vacuum. The loss-of-vacuum scenario resembles accidental venting of atmospheric air to the beam-line of a superconducting radio frequency particle accelerator and is investigated to understand how in the presence of condensation, the in-flowing air will propagate in such geometry. In a series of controlled experiments, room temperature nitrogen gas (a substitute for air) at a variety of mass flow rates was vented to a high vacuum tube immersed in a bath of liquid helium. Pressure probes and thermometers installed on the tube along its length measured respectively the tube pressure and tube wall temperature rise due to gas flooding and condensation. At high mass in-flow rates a gas front propagated down the vacuum tube but with a continuously decreasing speed. Regression analysis of the measured front arrival times indicates that the speed decreases nearly exponentially with the travel length. At low enough mass in-flow rates, no front propagated in the vacuum tube. Instead, the in-flowing gas steadily condensed over a short section of the tube near its entrance and the front appeared to `freeze-out'. An analytical expression is derived for gas front propagation speed in a vacuum tube in the presence of condensation. The analytical model qualitatively explains the front deceleration and flow freeze-out. The model is then simplified and supplemented with condensation heat/mass transfer data to again find the front to decelerate exponentially while going away from the tube entrance. Within the experimental and procedural uncertainty, the exponential decay length-scales obtained from the front arrival time regression and from the simplified model agree.

  15. Developing a vacuum cooking equipment prototype to produce strawberry jam and optimization of vacuum cooking conditions.

    PubMed

    Okut, Dilara; Devseren, Esra; Koç, Mehmet; Ocak, Özgül Özdestan; Karataş, Haluk; Kaymak-Ertekin, Figen

    2018-01-01

    Purpose of this study was to develop prototype cooking equipment that can work at reduced pressure and to evaluate its performance for production of strawberry jam. The effect of vacuum cooking conditions on color soluble solid content, reducing sugars total sugars HMF and sensory properties were investigated. Also, the optimum vacuum cooking conditions for strawberry jam were optimized for Composite Rotatable Design. The optimum cooking temperature and time were determined targeting maximum soluble solid content and sensory attributes (consistency) and minimum Hue value and HMF content. The optimum vacuum cooking conditions determined were 74.4 °C temperature and 19.8 time. The soluble solid content strawberry jam made by vacuum process were similar to those prepared by traditional method. HMF contents of jams produced with vacuum cooking method were well within limit of standards.

  16. 14 CFR 29.1433 - Vacuum systems.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Vacuum systems. 29.1433 Section 29.1433... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Equipment Miscellaneous Equipment § 29.1433 Vacuum systems. (a.... (b) Each vacuum air system line and fitting on the discharge side of the pump that might contain...

  17. Amplification of pressure waves in laser-assisted endodontics with synchronized delivery of Er:YAG laser pulses.

    PubMed

    Lukač, Nejc; Jezeršek, Matija

    2018-05-01

    When attempting to clean surfaces of dental root canals with laser-induced cavitation bubbles, the resulting cavitation oscillations are significantly prolonged due to friction on the cavity walls and other factors. Consequently, the collapses are less intense and the shock waves that are usually emitted following a bubble's collapse are diminished or not present at all. A new technique of synchronized laser-pulse delivery intended to enhance the emission of shock waves from collapsed bubbles in fluid-filled endodontic canals is reported. A laser beam deflection probe, a high-speed camera, and shadow photography were used to characterize the induced photoacoustic phenomena during synchronized delivery of Er:YAG laser pulses in a confined volume of water. A shock wave enhancing technique was employed which consists of delivering a second laser pulse at a delay with regard to the first cavitation bubble-forming laser pulse. Influence of the delay between the first and second laser pulses on the generation of pressure and shock waves during the first bubble's collapse was measured for different laser pulse energies and cavity volumes. Results show that the optimal delay between the two laser pulses is strongly correlated with the cavitation bubble's oscillation period. Under optimal synchronization conditions, the growth of the second cavitation bubble was observed to accelerate the collapse of the first cavitation bubble, leading to a violent collapse, during which shock waves are emitted. Additionally, shock waves created by the accelerated collapse of the primary cavitation bubble and as well of the accompanying smaller secondary bubbles near the cavity walls were observed. The reported phenomena may have applications in improved laser cleaning of surfaces during laser-assisted dental root canal treatments.

  18. Vacuum status-display and sector-conditioning programs

    NASA Astrophysics Data System (ADS)

    Skelly, J.; Yen, S.

    1990-08-01

    Two programs have been developed for observation and control of the AGS vacuum system, which include the following notable features: (1) they incorporate a graphical user interface and (2) they are driven by a relational database which describes the vacuum system. The vacuum system comprises some 440 devices organized into 28 vacuum sectors. The status-display program invites menu selection of a sector, interrogates the relational database for relevant vacuum devices, acquires live readbacks and posts a graphical display of their status. The sector-conditioning program likewise invites sector selection, produces the same status display and also implements process control logic on the sector devices to pump the sector down from atmospheric pressure to high vacuum over a period extending several hours. As additional devices are installed in the vacuum system, the devices are added to the relational database; these programs then automatically include the new devices.

  19. Working in a Vacuum

    ERIC Educational Resources Information Center

    Rathey, Allen

    2005-01-01

    In this article, the author discusses several myths about vacuum cleaners and offers tips on evaluating and purchasing this essential maintenance tool. These myths are: (1) Amps mean performance; (2) Everyone needs high-efficiency particulate air (HEPA): (3) Picking up a "bowling ball" shows cleaning power; (4) All vacuum bags are the same; (5)…

  20. Severe perineal laceration during operative vaginal delivery: the impact of occiput posterior position.

    PubMed

    Hirsch, E; Elue, R; Wagner, A; Nelson, K; Silver, R K; Zhou, Y; Adams, M G

    2014-12-01

    To identify risk factors for severe (third/fourth degree) perineal laceration with operative vaginal delivery (OVD, forceps or vacuum). Case-control study comparing singleton OVDs with or without severe laceration (n=138). In multivariable analyses, severe perineal laceration was associated with occiput posterior (OP) position at delivery, vaginal nulliparity, use of forceps, longer period pushing in the second stage and lower gestational age, but not birth weight, labor induction or episiotomy. Among 29 OP patients at full dilation, 9/13 (69%) attempted rotations to occiput anterior (OA) were successful, and 14/16 (88%) patients in whom rotation was not attempted remained OP at delivery. Successful rotation from OP to OA was associated with fewer severe lacerations than no attempt or unsuccessful rotation (22 vs 75%, P=0.01). Severe perineal laceration during OVD is associated with OP position at delivery and is reduced threefold in patients successfully rotated from OP to OA.

  1. The Relationship of Repeated Technical Assistance Support Visits to the Delivery of Positive Health, Dignity, and Prevention (PHDP) Messages by Healthcare Providers in Mozambique: A Longitudinal Multilevel Analysis.

    PubMed

    Gutin, Sarah A; Amico, K Rivet; Hunguana, Elsa; Munguambe, António Orlando; Rose, Carol Dawson

    Positive health, dignity, and prevention (PHDP) is Mozambique's strategy to engage clinicians in the delivery of prevention messages to their HIV-positive clients. This national implementation strategy uses provider trainings on offering key messages and focuses on intervening on 9 evidence-based risk reduction areas. We investigated the impact of longitudinal technical assistance (TA) as an addition to this basic training. We followed 153 healthcare providers in 5 Mozambican provinces over 6 months to evaluate the impact of on-site, observation-based TA on PHDP implementation. Longitudinal multilevel models were estimated to model change in PHDP message delivery over time among individual providers. With each additional TA visit, providers delivered about 1 additional PHDP message ( P < .001); clinicians and nonclinicians started at about the same baseline level, but clinicians improved more quickly ( P = .004). Message delivery varied by practice sector; maternal and child health sectors outperformed other sectors. Longitudinal TA helped reach the programmatic goals of the PHDP program in Mozambique.

  2. Vaginismus as an independent risk factor for cesarean delivery.

    PubMed

    Goldsmith, Tomer; Levy, Amalia; Sheiner, Eyal; Goldsmith, Tomer; Levy, Amalia; Sheiner, Eyal

    2009-10-01

    The present study was aimed to investigate pregnancy outcome of patients with vaginismus, and specifically the relationship between vaginismus and cesarean delivery. A population based study comparing all pregnancies in patients with and without vaginismus was conducted. Patients lacking prenatal care were excluded from the analysis. Deliveries occurred during the years 1988-2007. A multivariate logistic regression model, with backward elimination, was constructed to find independent risk factors associated with vaginismus. During the study period there were 192,954 deliveries, of which 118 occurred in patients with vaginismus. Patients with vaginismus tended to be younger (26.04+/-4.89 vs. 28.61+/-5.83; p < 0.001) and delivered smaller children (3024.2+/-517 g vs. 3160.9+/-576 g; p = 0.01) when compared with patients without vaginismus. Patients with vaginismus had higher rates of infertility treatments (5.9%vs. 2.7%, odds ratio [OR] 2.3; 95% confidence interval [CI] 1.1-4.9; p = 0.04) and labor induction (37.3%vs. 27.4%, OR 1.6; 95% CI 1.1-2.3; p = 0.02), vacuum extraction (9.3%vs. 2.8%, OR 3.6, 95% CI 1.9-6.7; p < 0.001), and cesarean delivery (39.0%vs. 14.5%, OR 3.8; 95% CI 2.6-5.5; p < 0.001) when compared with the comparison group. Even after controlling for possible confounders associated with cesarean delivery such as previous cesarean delivery, pathological presentations, and fetal distress, vaginismus remained as an independent risk factor for cesarean delivery (OR 7.1; 95% CI 4.5-11.1; p < 0.001). Vaginismus is an independent risk factor for cesarean delivery.

  3. 15 CFR 700.5 - Special priorities assistance.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... DEFENSE PRIORITIES AND ALLOCATIONS SYSTEM Overview § 700.5 Special priorities assistance. (a) The DPAS is designed to be largely self-executing. However, from time-to-time production or delivery problems will...

  4. 15 CFR 700.5 - Special priorities assistance.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... DEFENSE PRIORITIES AND ALLOCATIONS SYSTEM Overview § 700.5 Special priorities assistance. (a) The DPAS is designed to be largely self-executing. However, from time-to-time production or delivery problems will...

  5. 15 CFR 700.5 - Special priorities assistance.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... DEFENSE PRIORITIES AND ALLOCATIONS SYSTEM Overview § 700.5 Special priorities assistance. (a) The DPAS is designed to be largely self-executing. However, from time-to-time production or delivery problems will...

  6. 15 CFR 700.5 - Special priorities assistance.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... DEFENSE PRIORITIES AND ALLOCATIONS SYSTEM Overview § 700.5 Special priorities assistance. (a) The DPAS is designed to be largely self-executing. However, from time-to-time production or delivery problems will...

  7. 15 CFR 700.5 - Special priorities assistance.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... DEFENSE PRIORITIES AND ALLOCATIONS SYSTEM Overview § 700.5 Special priorities assistance. (a) The DPAS is designed to be largely self-executing. However, from time-to-time production or delivery problems will...

  8. Effective Delivery of Transition Assistance to Air Force Members Leaving the Service.

    DTIC Science & Technology

    1997-03-01

    Members Leaving the Service AF504R1/MARCH 1997 Executive Summary BACKGROUND Congress established the Transition Assistance Program (TAP) for the armed...forces in the National Defense Authorization Act for Fiscal Year 1991 (Public Law 101-510). This program assists military members and their families...other FSC program managers are responsible for delivering some transition services, espe- cially relocation assistance , financial counseling, and

  9. Nonperturbative vacuum polarization effects in two-dimensional supercritical Dirac-Coulomb system I. Vacuum charge density

    NASA Astrophysics Data System (ADS)

    Davydov, A.; Sveshnikov, K.; Voronina, Yu.

    2018-01-01

    Based on the original combination of analytical methods, computer algebra tools and numerical calculations, proposed recently in Refs. 1-3, the nonperturbative vacuum polarization effects in the 2+1D supercritical Dirac-Coulomb system with Z > Zcr,1 are explored. Both the vacuum charge density ρV P(r→) and vacuum energy ℰV P are considered. The main result of the work is that in the overcritical region ℰV P turns out to be a rapidly decreasing function ˜-ηeffZ3/R with ηeff > 0 and R being the size of the external Coulomb source. Due to a lot of details of calculation the whole work is divided into two parts I and II. In the present part I, we consider the evaluation and behavior of the vacuum density ρV P, which further is used in part II for evaluation of the vacuum energy, with emphasis on the renormalization, convergence of the partial expansion for ρV P and behavior of the integral induced charge QV P in the overcritical region.

  10. The Effect of Oxygen Partial Pressure on Microstructure and Properties of Fe40Al Alloy Sintered under Vacuum

    PubMed Central

    Siemiaszko, Dariusz; Kowalska, Beata; Jóźwik, Paweł; Kwiatkowska, Monika

    2015-01-01

    This paper presents the results of studies on the influence of oxygen partial pressure (vacuum level in the chamber) on the properties of FeAl intermetallics. One of the problems in the application of classical methods of prepared Fe-Al intermetallic is the occurrence of oxides. Applying a vacuum during sintering should reduce this effect. In order to analyze the effect of oxygen partial pressure on sample properties, five samples were processed (by a pressure-assisted induction sintering—PAIS method) under the following pressures: 3, 8, 30, 80, and 300 mbar (corresponding to oxygen partial pressures of 0.63, 1.68, 6.3, 16.8, and 63 mbar, respectively). The chemical and phase composition, hardness, density, and microstructure observations indicate that applying a vacuum significantly impacts intermetallic samples. The compact sintered at pressure 3 mbar is characterized by the most homogeneous microstructure, the highest density, high hardness, and nearly homogeneous chemical composition. PMID:28788015

  11. Nonperturbative vacuum polarization effects in two-dimensional supercritical Dirac-Coulomb system II. Vacuum energy

    NASA Astrophysics Data System (ADS)

    Davydov, A.; Sveshnikov, K.; Voronina, Yu.

    2018-01-01

    Nonperturbative vacuum polarization effects are explored for a supercritical Dirac-Coulomb system with Z > Zcr,1 in 2+1D, based on the original combination of analytical methods, computer algebra and numerical calculations, proposed recently in Refs. 1-3. Both the vacuum charge density ρV P(r→) and vacuum energy ℰV P are considered. Due to a lot of details of calculation the whole work is divided into two parts I and II. Taking account of results, obtained in the part I4 for ρV P, in the present part II, the evaluation of the vacuum energy ℰV P is investigated with emphasis on the renormalization and convergence of the partial expansion for ℰV P. It is shown that the renormalization via fermionic loop turns out to be the universal tool, which removes the divergence of the theory both in the purely perturbative and essentially nonperturbative regimes of the vacuum polarization. The main result of calculation is that for a wide range of the system parameters in the overcritical region ℰV P turns out to be a rapidly decreasing function ˜-ηeffZ3/R with ηeff > 0 and R being the size of the external Coulomb source. To the end the similarity in calculations of ℰV P in 2+1 and 3+1D is discussed, and qualitative arguments are presented in favor of the possibility for complete screening of the classical electrostatic energy of the Coulomb source by the vacuum polarization effects for Z ≫ Zcr,1 in 3+1D.

  12. Quantum vacuum noise in physics and cosmology.

    PubMed

    Davies, P. C. W.

    2001-09-01

    The concept of the vacuum in quantum field theory is a subtle one. Vacuum states have a rich and complex set of properties that produce distinctive, though usually exceedingly small, physical effects. Quantum vacuum noise is familiar in optical and electronic devices, but in this paper I wish to consider extending the discussion to systems in which gravitation, or large accelerations, are important. This leads to the prediction of vacuum friction: The quantum vacuum can act in a manner reminiscent of a viscous fluid. One result is that rapidly changing gravitational fields can create particles from the vacuum, and in turn the backreaction on the gravitational dynamics operates like a damping force. I consider such effects in early universe cosmology and the theory of quantum black holes, including the possibility that the large-scale structure of the universe might be produced by quantum vacuum noise in an early inflationary phase. I also discuss the curious phenomenon that an observer who accelerates through a quantum vacuum perceives a bath of thermal radiation closely analogous to Hawking radiation from black holes, even though an inertial observer registers no particles. The effects predicted raise very deep and unresolved issues about the nature of quantum particles, the role of the observer, and the relationship between the quantum vacuum and the concepts of information and entropy. (c) 2001 American Institute of Physics.

  13. Running vacuum cosmological models: linear scalar perturbations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perico, E.L.D.; Tamayo, D.A., E-mail: elduartep@usp.br, E-mail: tamayo@if.usp.br

    In cosmology, phenomenologically motivated expressions for running vacuum are commonly parameterized as linear functions typically denoted by Λ( H {sup 2}) or Λ( R ). Such models assume an equation of state for the vacuum given by P-bar {sub Λ} = - ρ-bar {sub Λ}, relating its background pressure P-bar {sub Λ} with its mean energy density ρ-bar {sub Λ} ≡ Λ/8π G . This equation of state suggests that the vacuum dynamics is due to an interaction with the matter content of the universe. Most of the approaches studying the observational impact of these models only consider the interactionmore » between the vacuum and the transient dominant matter component of the universe. We extend such models by assuming that the running vacuum is the sum of independent contributions, namely ρ-bar {sub Λ} = Σ {sub i} ρ-bar {sub Λ} {sub i} . Each Λ i vacuum component is associated and interacting with one of the i matter components in both the background and perturbation levels. We derive the evolution equations for the linear scalar vacuum and matter perturbations in those two scenarios, and identify the running vacuum imprints on the cosmic microwave background anisotropies as well as on the matter power spectrum. In the Λ( H {sup 2}) scenario the vacuum is coupled with every matter component, whereas the Λ( R ) description only leads to a coupling between vacuum and non-relativistic matter, producing different effects on the matter power spectrum.« less

  14. Microwave-assisted extraction performed in low temperature and in vacuo for the extraction of labile compounds in food samples.

    PubMed

    Xiao, Xiaohua; Song, Wei; Wang, Jiayue; Li, Gongke

    2012-01-27

    In this study, low temperature vacuum microwave-assisted extraction, which simultaneous performed microwave-assisted extraction (MAE) in low temperature and in vacuo environment, was proposed. The influencing parameters including solid/liquid ratio, extraction temperature, extraction time, degree of vacuum and microwave power were discussed. The predominance of low temperature vacuum microwave-assisted extraction was investigated by comparing the extraction yields of vitamin C, β-carotene, aloin A and astaxanthin in different foods with that in MAE and solvent extraction, and 5.2-243% increments were obtained. On the other hand, the chemical kinetics of vitamin C and aloin A, which composed two different steps including the extraction step of analyte transferred from matrix into solvent and the decomposition step of analyte degraded in the extraction solvent, were proposed. All of the decomposition rates (K(2)) for the selected analyte in low temperature, in vacuo and in nitrogen atmosphere decreased significantly comparing with that in conventional MAE, which are in agreement with that obtained from experiments. Consequently, the present method was successfully applied to extract labile compound from different food samples. These results showed that low temperature and/or in vacuo environment in microwave-assisted extraction system was especially important to prevent the degradation of labile components and have good potential on the extraction of labile compound in foods, pharmaceutical and natural products. Copyright © 2011 Elsevier B.V. All rights reserved.

  15. Vacuum phonon tunneling.

    PubMed

    Altfeder, Igor; Voevodin, Andrey A; Roy, Ajit K

    2010-10-15

    Field-induced phonon tunneling, a previously unknown mechanism of interfacial thermal transport, has been revealed by ultrahigh vacuum inelastic scanning tunneling microscopy (STM). Using thermally broadened Fermi-Dirac distribution in the STM tip as in situ atomic-scale thermometer we found that thermal vibrations of the last tip atom are effectively transmitted to sample surface despite few angstroms wide vacuum gap. We show that phonon tunneling is driven by interfacial electric field and thermally vibrating image charges, and its rate is enhanced by surface electron-phonon interaction.

  16. 21 CFR 884.4340 - Fetal vacuum extractor.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... means of a suction cup attached to the scalp and is powered by an external vacuum source. This generic type of device may include the cup, hosing, vacuum source, and vacuum control. (b) Classification...

  17. 21 CFR 884.4340 - Fetal vacuum extractor.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... means of a suction cup attached to the scalp and is powered by an external vacuum source. This generic type of device may include the cup, hosing, vacuum source, and vacuum control. (b) Classification...

  18. Cold cathode vacuum gauging system

    DOEpatents

    Denny, Edward C.

    2004-03-09

    A vacuum gauging system of the cold cathode type is provided for measuring the pressure of a plurality of separate vacuum systems, such as in a gas centrifuge cascade. Each casing is fitted with a gauge tube assembly which communicates with the vacuum system in the centrifuge casing. Each gauge tube contains an anode which may be in the form of a slender rod or wire hoop and a cathode which may be formed by the wall of the gauge tube. The tube is provided with an insulated high voltage connector to the anode which has a terminal for external connection outside the vacuum casing. The tube extends from the casing so that a portable magnet assembly may be inserted about the tube to provide a magnetic field in the area between the anode and cathode necessary for pressure measurements in a cold cathode-type vacuum gauge arrangement. The portable magnetic assembly is provided with a connector which engages the external high voltage terminal for providing power to the anode within in the gauge tube. Measurement is made in the same manner as the prior cold cathode gauges in that the current through the anode to the cathode is measured as an indication of the pressure. By providing the portable magnetic assembly, a considerable savings in cost, installation, and maintenance of vacuum gauges for pressure measurement in a gas centrifuge cascade is realizable.

  19. Measurement of partial pressures in vacuum technology and vacuum physics

    NASA Technical Reports Server (NTRS)

    Huber, W. K.

    1986-01-01

    It is pointed out that the measurement of gaseous pressures of less than 0.0001 torr is based on the ionization of gas atoms and molecules due to collisions with electrons. The particle density is determined in place of the pressure. The ionization cross sections for molecules of various gases are discussed. It is found that the true pressure in a vacuum system cannot be determined with certainty if it is unknown which gas is present. Effects of partial pressure determination on the condition of the vacuum system are discussed together with ion sources, systems of separation, and ion detection.

  20. VACUUM TRAP AND VALVE COMBINATION

    DOEpatents

    Milleron, N.; Levenson, L.

    1963-02-19

    This patent relates to a vacuum trap and valve combination suitable for use in large ultra-high vacuum systems. The vacuum trap is a chamber having an inlet and outlet opening which may be made to communicate with a chamber to be evacuated and a diffusion pump, respectively. A valve is designed to hermeticaliy seal with inlet opening and, when opened, block the line-of- sight'' between the inlet and outlet openings, while allowing a large flow path between the opened vaive and the side walls of the trap. The interior of the trap and the side of the valve facing the inlet opening are covered with an impurity absorbent, such as Zeolite or activated aluminum. Besides the advantage of combining two components of a vacuum system into one, the present invention removes the need for a baffle between the pump and the chamber to be evacuated. In one use of a specific embodiment of this invention, the transmission probability was 45 and the partial pressure of the pump fluid vapor in the vacuum chamber was at least 100 times lower than its vapor pressure. (AEC)

  1. Assisted reproductive technology in the United States: 2001 results generated from the American Society for Reproductive Medicine/Society for Assisted Reproductive Technology registry.

    PubMed

    2007-06-01

    To summarize the procedures and outcomes of assisted reproductive technologies (ART) that were initiated in the United States in 2001. Data were collected electronically using the Society for Assisted Reproductive Technology (SART) Clinic Outcome Reporting System software and submitted to the American Society for Reproductive Medicine/SART Registry. Three hundred eighty-five clinics submitted data on procedures performed in 2001. Data were collated after November 2002 [corrected] so that the outcomes of all pregnancies would be known. Incidence of clinical pregnancy, ectopic pregnancy, abortion, stillbirth, and delivery. Programs reported initiating 108,130 cycles of ART treatment. Of these, 79,042 cycles involved IVF (with and without micromanipulation), with a delivery rate per retrieval of 31.6%; 340 were cycles of gamete intrafallopian transfer, with a delivery rate per retrieval of 21.9%; 661 were cycles of zygote intrafallopian transfer, with a delivery rate per retrieval of 31.0%. The following additional ART procedures were also initiated: 8,147 fresh donor oocyte cycles, with a delivery rate per transfer of 47.3%; 14,509 frozen ET procedures, with a delivery rate per transfer of 23.5%; 3,187 frozen ETs employing donated oocytes or embryos, with a delivery rate per transfer of 27.4%; and 1,366 cycles using a host uterus, with a delivery rate per transfer of 38.7%. In addition, 112 cycles were reported as combinations of more than one treatment type, 8 cycles as research, and 85 as embryo banking. As a result of all procedures, 29,585 deliveries were reported, resulting in 41,168 neonates. In 2001, there were more programs reporting ART treatment and a significant increase in reported cycles compared with 2000.

  2. PROMOTE Study: Safety of Osteopathic Manipulative Treatment During the Third Trimester by Labor and Delivery Outcomes.

    PubMed

    Hensel, Kendi L; Roane, Brandy M; Chaphekar, Anita Vikas; Smith-Barbaro, Peggy

    2016-11-01

    Few quality data exist on the safety of osteopathic manipulative treatment (OMT) during pregnancy. The Pregnancy Research on Osteopathic Manipulation Optimizing Treatment Effects (PROMOTE) study was a randomized controlled clinical trial that studied the application of an OMT protocol to manage pain and dysfunction in pregnant patients during their third trimester. To evaluate the safety of an OMT protocol applied during the third trimester of pregnancy by analyzing incidence of high-risk status and labor and delivery outcomes. In the PROMOTE study, 400 pregnant patients were randomly assigned to 1 of 3 study groups: usual care plus OMT (OMT), usual care plus placebo ultrasound treatment (PUT), or usual care only (UCO). The incidence of high-risk status of participants and outcomes of labor and delivery, including length of labor, fever in mother during labor, operative vaginal delivery, conversion to cesarean delivery, need for forceps or vacuum device, need for episiotomy, incidence of perineal laceration, meconium-stained amniotic fluid, and infants' Apgar scores, were analyzed. Data from 380 participants were studied. High-risk status was less likely to develop in participants who received OMT (95% CI, 0.16-0.91; P=.03). The OMT protocol also did not increase risk of precipitous labor, operative vaginal delivery, conversion to cesarean delivery, need for forceps or vacuum device, need for episiotomy, incidence of perineal laceration, or meconium-stained amniotic fluid when compared with participants in the other 2 groups (P>.05). Of all other maternal outcomes examined, no difference was reported among the 3 treatment groups with the exception of incidence of prolonged labor in the OMT group. Participants receiving OMT had longer durations of labor than participants in the other groups (P=.002). These results suggest that the OMT protocol given during the third trimester of pregnancy as applied in the PROMOTE study is safe with regard to labor and delivery

  3. Vacuum enhanced cutaneous biopsy instrument

    DOEpatents

    Collins, Joseph

    2000-01-01

    A syringe-like disposable cutaneous biopsy instrument equipped with a tubular blade at its lower end, and designed so that a vacuum is created during use, said vacuum serving to retain undeformed a plug of tissue cut from a patient's skin.

  4. Troubleshooting crude vacuum tower overhead ejector systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lines, J.R.; Frens, L.L.

    1995-03-01

    Routinely surveying tower overhead vacuum systems can improve performance and product quality. These vacuum systems normally provide reliable and consistent operation. However, process conditions, supplied utilities, corrosion, erosion and fouling all have an impact on ejector system performance. Refinery vacuum distillation towers use ejector systems to maintain tower top pressure and remove overhead gases. However, as with virtually all refinery equipment, performance may be affected by a number of variables. These variables may act independently or concurrently. It is important to understand basic operating principles of vacuum systems and how performance is affected by: utilities, corrosion and erosion, fouling, andmore » process conditions. Reputable vacuum-system suppliers have service engineers that will come to a refinery to survey the system and troubleshoot performance or offer suggestions for improvement. A skilled vacuum-system engineer may be needed to diagnose and remedy system problems. The affect of these variables on performance is discussed. A case history is described of a vacuum system on a crude tower in a South American refinery.« less

  5. Vapor-barrier Vacuum Isolation System

    NASA Technical Reports Server (NTRS)

    Weinstein, Leonard M. (Inventor); Taminger, Karen M. (Inventor)

    2014-01-01

    A system includes a collimated beam source within a vacuum chamber, a condensable barrier gas, cooling material, a pump, and isolation chambers cooled by the cooling material to condense the barrier gas. Pressure levels of each isolation chamber are substantially greater than in the vacuum chamber. Coaxially-aligned orifices connect a working chamber, the isolation chambers, and the vacuum chamber. The pump evacuates uncondensed barrier gas. The barrier gas blocks entry of atmospheric vapor from the working chamber into the isolation chambers, and undergoes supersonic flow expansion upon entering each isolation chamber. A method includes connecting the isolation chambers to the vacuum chamber, directing vapor to a boundary with the working chamber, and supersonically expanding the vapor as it enters the isolation chambers via the orifices. The vapor condenses in each isolation chamber using the cooling material, and uncondensed vapor is pumped out of the isolation chambers via the pump.

  6. 7 CFR 58.423 - Cheese vacuumizing chamber.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Cheese vacuumizing chamber. 58.423 Section 58.423 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards....423 Cheese vacuumizing chamber. The vacuum chamber shall be satisfactorily constructed and maintained...

  7. 7 CFR 58.423 - Cheese vacuumizing chamber.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Cheese vacuumizing chamber. 58.423 Section 58.423 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards....423 Cheese vacuumizing chamber. The vacuum chamber shall be satisfactorily constructed and maintained...

  8. Engineering Matter Interactions Using Squeezed Vacuum

    NASA Astrophysics Data System (ADS)

    Zeytinoǧlu, Sina; Imamoǧlu, Ataç; Huber, Sebastian

    2017-04-01

    Virtually all interactions that are relevant for atomic and condensed matter physics are mediated by quantum fluctuations of the electromagnetic field vacuum. Consequently, controlling the vacuum fluctuations can be used to engineer the strength and the range of interactions. Recent experiments have used this premise to demonstrate novel quantum phases or entangling gates by embedding electric dipoles in photonic cavities or wave guides, which modify the electromagnetic fluctuations. Here, we show theoretically that the enhanced fluctuations in the antisqueezed quadrature of a squeezed vacuum state allow for engineering interactions between electric dipoles without the need for a photonic structure. Thus, the strength and range of the interactions can be engineered in a time-dependent way by changing the spatial profile of the squeezed vacuum in a traveling-wave geometry, which also allows the implementation of chiral dissipative interactions. Using experimentally realized squeezing parameters and including realistic losses, we predict single-atom cooperativities C of up to 10 for the squeezed-vacuum-enhanced interactions.

  9. Lightweight Vacuum Jacket for Cryogenic Insulation. Volume 1

    NASA Technical Reports Server (NTRS)

    Barclay, D. L.; Bell, J. E.; Brogren, E. W.; Straayer, J. W.

    1975-01-01

    The feasibility of producing a lightweight vacuum jacket using state-of-the-art technology and materials was examined. Design and analytical studies were made on a full-scale, orbital maneuvering system fuel tank. Preliminary design details were made for the tank assembly, including an optimized vacuum jacket and multilayer insulation system. A half-scale LH2 test model was designed and fabricated, and a force/stiffness proof test was conducted on the vacuum jacket. A vacuum leak rate of .000001 atmosphere ml of helium per second was measured, approximately 1500 hours of vacuum pressure were sustained, and 29 vacuum-pressure cycles were experienced prior to failure.

  10. How to Improve the Design and Delivery of High-Quality Technical Assistance. Newsletter

    ERIC Educational Resources Information Center

    Center for Comprehensive School Reform and Improvement, 2005

    2005-01-01

    Educators often use the term technical assistance to define services delivered or received in the pursuit of school- and district-improvement initiatives. More specifically, technical assistance can be defined as any assistance that identifies, selects, or designs research-based solutions and practices to support school improvement (Mattson &…

  11. 7 CFR 305.29 - Vacuum heat treatment schedule.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 5 2010-01-01 2010-01-01 false Vacuum heat treatment schedule. 305.29 Section 305.29... SERVICE, DEPARTMENT OF AGRICULTURE PHYTOSANITARY TREATMENTS Heat Treatments § 305.29 Vacuum heat treatment... vacuum at 8 hours. Maintain the vacuum until the end of the treatment. Gradually increase the temperature...

  12. Drug self-delivery systems for cancer therapy.

    PubMed

    Qin, Si-Yong; Zhang, Ai-Qing; Cheng, Si-Xue; Rong, Lei; Zhang, Xian-Zheng

    2017-01-01

    Carrier-assistant drug delivery systems (DDSs) have been rapidly established for cancer therapy and great strides have been made in recent years. However, further development of DDSs is retarded by the aspects such as the low drug carrying capacity, carrier-induced toxicity and immunogenicity, complex synthesis manipulation. Drug self-delivery systems (DSDSs), in which active drugs exhibit nanoscale characteristic to realize intracellular delivery by themselves without the help of nanocarriers, have been rapidly developed to address these issues. In this review, we present a comprehensive summary of the recent advances in DSDSs for cancer therapy. After a brief introduction to the major types of DSDSs and their fabrication strategies, we emphatically discuss some representative achievements of these DSDSs for passive or/and positive targeting therapy, combinational therapy as well as theranostics. The design principle is explained and justified, which can cast a new light on developing drug delivery systems for cancer treatments. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Gravitational collapse and the vacuum energy

    NASA Astrophysics Data System (ADS)

    Campos, M.

    2014-03-01

    To explain the accelerated expansion of the universe, models with interacting dark components (dark energy and dark matter) have been considered recently in the literature. Generally, the dark energy component is physically interpreted as the vacuum energy of the all fields that fill the universe. As the other side of the same coin, the influence of the vacuum energy on the gravitational collapse is of great interest. We study such collapse adopting different parameterizations for the evolution of the vacuum energy. We discuss the homogeneous collapsing star fluid, that interacts with a vacuum energy component, using the stiff matter case as example. We conclude this work with a discussion of the Cahill-McVittie mass for the collapsed object.

  14. Gravitational baryogenesis in running vacuum models

    NASA Astrophysics Data System (ADS)

    Oikonomou, V. K.; Pan, Supriya; Nunes, Rafael C.

    2017-08-01

    We study the gravitational baryogenesis mechanism for generating baryon asymmetry in the context of running vacuum models. Regardless of whether these models can produce a viable cosmological evolution, we demonstrate that they produce a nonzero baryon-to-entropy ratio even if the universe is filled with conformal matter. This is a sound difference between the running vacuum gravitational baryogenesis and the Einstein-Hilbert one, since in the latter case, the predicted baryon-to-entropy ratio is zero. We consider two well known and most used running vacuum models and show that the resulting baryon-to-entropy ratio is compatible with the observational data. Moreover, we also show that the mechanism of gravitational baryogenesis may constrain the running vacuum models.

  15. Ionization-Assisted Getter Pumping for Ultra-Stable Trapped Ion Frequency Standards

    NASA Technical Reports Server (NTRS)

    Tjoelker, Robert L.; Burt, Eric A.

    2010-01-01

    A method eliminates (or recovers from) residual methane buildup in getter-pumped atomic frequency standard systems by applying ionizing assistance. Ultra-high stability trapped ion frequency standards for applications requiring very high reliability, and/or low power and mass (both for ground-based and space-based platforms) benefit from using sealed vacuum systems. These systems require careful material selection and system processing (cleaning and high-temperature bake-out). Even under the most careful preparation, residual hydrogen outgassing from vacuum chamber walls typically limits the base pressure. Non-evaporable getter pumps (NEGs) provide a convenient pumping option for sealed systems because of low mass and volume, and no power once activated. An ion gauge in conjunction with a NEG can be used to provide a low mass, low-power method for avoiding the deleterious effects of methane buildup in high-performance frequency standard vacuum systems.

  16. Recovery of materials from waste printed circuit boards by vacuum pyrolysis and vacuum centrifugal separation.

    PubMed

    Zhou, Yihui; Wu, Wenbiao; Qiu, Keqiang

    2010-11-01

    In this research, a two-step process consisting of vacuum pyrolysis and vacuum centrifugal separation was employed to treat waste printed circuit boards (WPCBs). Firstly, WPCBs were pyrolysed under vacuum condition at 600 °C for 30 min in a lab-scale reactor. Then, the obtained pyrolysis residue was heated under vacuum until the solder was melted, and then the molten solder was separated from the pyrolysis residue by the centrifugal force. The results of vacuum pyrolysis showed that the type-A of WPCBs (the base plates of which was made from cellulose paper reinforced phenolic resin) pyrolysed to form an average of 67.97 wt.% residue, 27.73 wt.% oil, and 4.30 wt.% gas; and pyrolysis of the type-B of WPCBs (the base plates of which was made from glass fiber reinforced epoxy resin) led to an average mass balance of 72.20 wt.% residue, 21.45 wt.% oil, and 6.35 wt.% gas. The results of vacuum centrifugal separation showed that the separation of solder was complete when the pyrolysis residue was heated at 400 °C, and the rotating drum was rotated at 1200 rpm for 10 min. The pyrolysis oil and gas can be used as fuel or chemical feedstock after treatment. The pyrolysis residue after solder separation contained various metals, glass fibers and other inorganic materials, which could be recycled for further processing. The recovered solder can be reused directly and it can also be a good resource of lead and tin for refining. Copyright © 2010 Elsevier Ltd. All rights reserved.

  17. Diffraction-limited storage-ring vacuum technology

    PubMed Central

    Al-Dmour, Eshraq; Ahlback, Jonny; Einfeld, Dieter; Tavares, Pedro Fernandes; Grabski, Marek

    2014-01-01

    Some of the characteristics of recent ultralow-emittance storage-ring designs and possibly future diffraction-limited storage rings are a compact lattice combined with small magnet apertures. Such requirements present a challenge for the design and performance of the vacuum system. The vacuum system should provide the required vacuum pressure for machine operation and be able to handle the heat load from synchrotron radiation. Small magnet apertures result in the conductance of the chamber being low, and lumped pumps are ineffective. One way to provide the required vacuum level is by distributed pumping, which can be realised by the use of a non-evaporable getter (NEG) coating of the chamber walls. It may not be possible to use crotch absorbers to absorb the heat from the synchrotron radiation because an antechamber is difficult to realise with such a compact lattice. To solve this, the chamber walls can work as distributed absorbers if they are made of a material with good thermal conductivity, and distributed cooling is used at the location where the synchrotron radiation hits the wall. The vacuum system of the 3 GeV storage ring of MAX IV is used as an example of possible solutions for vacuum technologies for diffraction-limited storage rings. PMID:25177979

  18. A multicentre randomized controlled trial of gentle assisted pushing in the upright posture (GAP) or upright posture alone compared with routine practice to reduce prolonged second stage of labour (the Gentle Assisted Pushing study): study protocol.

    PubMed

    Hofmeyr, G Justus; Singata, Mandisa; Lawrie, Theresa; Vogel, Joshua P; Landoulsi, Sihem; Seuc, Armando H; Gülmezoglu, A Metin

    2015-12-16

    Fundal pressure (pushing on the upper part of the uterus in the direction of the birth canal) is often performed in routine practice, however the benefit and indications for its use are unclear and vigorous pressure is potentially harmful. There is some evidence that it may be applied routinely or to expedite delivery in some situations (e.g. fetal distress or maternal exhaustion), particularly in settings where other methods of achieving delivery (forceps, vacuum) are not available. Gentle assisted pushing (GAP) is an innovative method of applying gentle but steady pressure to the uterine fundus with the woman in an upright posture. This trial aims to evaluate the use of GAP in an upright posture, or upright posture alone, on reducing the mean time of delivery and the associated maternal and neonatal complications in women not having delivered following 15-30 min in the second stage of labour. We will conduct a multicentre, randomized, unblinded, controlled trial with three parallel arms (1:1:1). 1,145 women will be randomized at three hospitals in South Africa. Women will be eligible for inclusion if they are ≥18 years old, nulliparous, gestational age ≥ 35 weeks, have a singleton pregnancy in cephalic presentation and vaginal delivery anticipated. Women with chronic medical conditions or obstetric complications are not eligible. If eligible women are undelivered following 15-30 min in the second stage of labour, they will be randomly assigned to: 1) GAP in the upright posture, 2) upright posture only and 3) routine practice (recumbent/supine posture). The primary outcome is the mean time from randomization to complete delivery. Secondary outcomes include operative delivery, adverse neonatal outcomes, maternal adverse events and discomfort. This trial will establish whether upright posture and/or a controlled method of applying fundal pressure (GAP) can improve labour outcomes for women and their babies. If fundal pressure is found to have a measurable

  19. Electric Propulsion Laboratory Vacuum Chamber

    NASA Image and Video Library

    1964-06-21

    Engineer Paul Reader and his colleagues take environmental measurements during testing of a 20-inch diameter ion engine in a vacuum tank at the Electric Propulsion Laboratory (EPL). Researchers at the Lewis Research Center were investigating the use of a permanent-magnet circuit to create the magnetic field required power electron bombardment ion engines. Typical ion engines use a solenoid coil to create this magnetic field. It was thought that the substitution of a permanent magnet would create a comparable magnetic field with a lower weight. Testing of the magnet system in the EPL vacuum tanks revealed no significant operational problems. Reader found the weight of the two systems was similar, but that the thruster’s efficiency increased with the magnet. The EPL contained a series of large vacuum tanks that could be used to simulate conditions in space. Large vacuum pumps reduced the internal air pressure, and a refrigeration system created the cryogenic temperatures found in space.

  20. Night vision imaging system design, integration and verification in spacecraft vacuum thermal test

    NASA Astrophysics Data System (ADS)

    Shang, Yonghong; Wang, Jing; Gong, Zhe; Li, Xiyuan; Pei, Yifei; Bai, Tingzhu; Zhen, Haijing

    2015-08-01

    The purposes of spacecraft vacuum thermal test are to characterize the thermal control systems of the spacecraft and its component in its cruise configuration and to allow for early retirement of risks associated with mission-specific and novel thermal designs. The orbit heat flux is simulating by infrared lamp, infrared cage or electric heater. As infrared cage and electric heater do not emit visible light, or infrared lamp just emits limited visible light test, ordinary camera could not operate due to low luminous density in test. Moreover, some special instruments such as satellite-borne infrared sensors are sensitive to visible light and it couldn't compensate light during test. For improving the ability of fine monitoring on spacecraft and exhibition of test progress in condition of ultra-low luminous density, night vision imaging system is designed and integrated by BISEE. System is consist of high-gain image intensifier ICCD camera, assistant luminance system, glare protect system, thermal control system and computer control system. The multi-frame accumulation target detect technology is adopted for high quality image recognition in captive test. Optical system, mechanical system and electrical system are designed and integrated highly adaptable to vacuum environment. Molybdenum/Polyimide thin film electrical heater controls the temperature of ICCD camera. The results of performance validation test shown that system could operate under vacuum thermal environment of 1.33×10-3Pa vacuum degree and 100K shroud temperature in the space environment simulator, and its working temperature is maintains at 5° during two-day test. The night vision imaging system could obtain video quality of 60lp/mm resolving power.

  1. Vacuum Energy and Inflation: 4. An Inflationary Universe

    ERIC Educational Resources Information Center

    Huggins, Elisha

    2013-01-01

    This is the fourth paper in a series of four. The first paper in the series, "Vacuum Energy and Inflation: 1. A Liter of Vacuum Energy" [EJ1024183] discusses an example of vacuum energy. Vacuum energy is explained as an energy with a negative pressure whose energy density remains constant in an expanding space. Paper 2, "Vacuum…

  2. Impella™ Left Ventricular Assist Device for Acute Peripartum Cardiomyopathy After Cesarean Delivery.

    PubMed

    Padilla, Cesar; Hernandez Conte, Antonio; Ramzy, Danny; Sanchez, Michael; Zhao, Manxu; Park, Donald; Lubin, Lorraine

    2016-07-01

    Peripartum cardiomyopathy is a rare form of heart failure with significant perioperative implications. In this case report, we describe a 34-year-old gravida 5, parity 3, patient who was admitted for an elective cesarean delivery. During the delivery, the patient developed sudden cardiac arrest and was emergently intubated in the operating room. An emergent transesophageal echocardiogram revealed a left ventricular ejection fraction of 10% with global biventricular hypokinesis. Urgent multidisciplinary consultations led to the rapid implementation of the Impella™ 2.5 for ventricular support. The patient recovered ventricular function within 4 days and recovered to baseline function.

  3. Quantum vacuum polarization, nanotechnology and a robotic mission to Proxima Centauri

    NASA Astrophysics Data System (ADS)

    de Morais Mendonca Teles, Antonio

    inertial mass of the mini-spacecraft has a relativistic increase factor of 0.005, fifty years of mission is a feasible one. A way of achieving this is by using altogether the possible available spacecraft acceleration: gravity assistance, ionic propulsion, and using characteristics of the medium through which any spacecrafts travel by -vacuum. Vacuum has intrinsic quantum properties such as quantum tunneling, latent quantum residual energy, and the quantum vac-uum polarization phenomenon. I also propose the use of such quantum vacuum polarization (QVP) for the propulsion assistance for possible future Solar System and interstellar missions. QVP is a natural phenomenon arisen as a second-order correction for perturbation of quantum vacuum fluctuations, within the quantum field physics arena. It is related experimentally to the Casimir effect (the appearance of a negative potential barrier between very close and par-allel metallic plates in vacuum). Using a laser beam with a minimum of 1.22 MeV energy it is possible to create inside those plates in vacuum 1 real pair of electron-positron (anti-electron), and associated with this there is the creation of 1 virtual pair of electron-positron, through the geometrodynamical arrangement of the quantum vacuum fluctuations states, with a very small interval of time (δt). With much greater energies (GeV, TeV) it is possible to create virtual pairs with much longer δt, with the appearance of a repulsive force between the real and asso-ciated virtual pairs, caused by forced alignment of the spins of the real and virtual pairs. This could be attained by the use of a magnetic field. A powerful laser put in the extremity of the mini-spacecraft (together with the ionic mini-motor) in the middle of Casimir plates, could use that repulsive force to get much more momentum to the mini-spacecraft, for a possible speed in the order of 0.1 c. Telecommunication aspect can be arranged through the use of a tracking and data relay mini

  4. 21 CFR 884.5070 - Vacuum abortion system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vacuum abortion system. 884.5070 Section 884.5070 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... § 884.5070 Vacuum abortion system. (a) Identification. A vacuum abortion system is a device designed to...

  5. 46 CFR 153.368 - Pressure-vacuum valves.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 5 2014-10-01 2014-10-01 false Pressure-vacuum valves. 153.368 Section 153.368 Shipping... BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Cargo Venting Systems § 153.368 Pressure-vacuum valves. (a) The pressure side of a required pressure-vacuum relief valve...

  6. 46 CFR 153.368 - Pressure-vacuum valves.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 5 2011-10-01 2011-10-01 false Pressure-vacuum valves. 153.368 Section 153.368 Shipping... BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Cargo Venting Systems § 153.368 Pressure-vacuum valves. (a) The pressure side of a required pressure-vacuum relief valve...

  7. 46 CFR 153.368 - Pressure-vacuum valves.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 5 2012-10-01 2012-10-01 false Pressure-vacuum valves. 153.368 Section 153.368 Shipping... BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Cargo Venting Systems § 153.368 Pressure-vacuum valves. (a) The pressure side of a required pressure-vacuum relief valve...

  8. 46 CFR 153.368 - Pressure-vacuum valves.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 5 2013-10-01 2013-10-01 false Pressure-vacuum valves. 153.368 Section 153.368 Shipping... BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Cargo Venting Systems § 153.368 Pressure-vacuum valves. (a) The pressure side of a required pressure-vacuum relief valve...

  9. 46 CFR 153.368 - Pressure-vacuum valves.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Pressure-vacuum valves. 153.368 Section 153.368 Shipping... BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Cargo Venting Systems § 153.368 Pressure-vacuum valves. (a) The pressure side of a required pressure-vacuum relief valve...

  10. 21 CFR 884.5070 - Vacuum abortion system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Vacuum abortion system. 884.5070 Section 884.5070 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... § 884.5070 Vacuum abortion system. (a) Identification. A vacuum abortion system is a device designed to...

  11. 21 CFR 884.5070 - Vacuum abortion system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Vacuum abortion system. 884.5070 Section 884.5070 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... § 884.5070 Vacuum abortion system. (a) Identification. A vacuum abortion system is a device designed to...

  12. 21 CFR 884.5070 - Vacuum abortion system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Vacuum abortion system. 884.5070 Section 884.5070 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... § 884.5070 Vacuum abortion system. (a) Identification. A vacuum abortion system is a device designed to...

  13. 21 CFR 884.5070 - Vacuum abortion system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Vacuum abortion system. 884.5070 Section 884.5070 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... § 884.5070 Vacuum abortion system. (a) Identification. A vacuum abortion system is a device designed to...

  14. The localized quantum vacuum field

    NASA Astrophysics Data System (ADS)

    Dragoman, D.

    2008-03-01

    A model for the localized quantum vacuum is proposed in which the zero-point energy (ZPE) of the quantum electromagnetic field originates in energy- and momentum-conserving transitions of material systems from their ground state to an unstable state with negative energy. These transitions are accompanied by emissions and re-absorptions of real photons, which generate a localized quantum vacuum in the neighborhood of material systems. The model could help resolve the cosmological paradox associated with the ZPE of electromagnetic fields, while reclaiming quantum effects associated with quantum vacuum such as the Casimir effect and the Lamb shift. It also offers a new insight into the Zitterbewegung of material particles.

  15. Multifaceted Applications of Chitosan in Cancer Drug Delivery and Therapy.

    PubMed

    Babu, Anish; Ramesh, Rajagopal

    2017-03-27

    Chitosan is a versatile polysaccharide of biological origin. Due to the biocompatible and biodegradable nature of chitosan, it is intensively utilized in biomedical applications in scaffold engineering as an absorption enhancer, and for bioactive and controlled drug release. In cancer therapy, chitosan has multifaceted applications, such as assisting in gene delivery and chemotherapeutic delivery, and as an immunoadjuvant for vaccines. The present review highlights the recent applications of chitosan and chitosan derivatives in cancer therapy.

  16. Vacuum casting of thick polymeric films

    NASA Technical Reports Server (NTRS)

    Cuddihy, E. F.; Moacanin, J.

    1979-01-01

    Bubble formation and layering, which often plague vacuum-evaporated films, are prevented by properly regulating process parameters. Vacuum casting may be applicable to forming thick films of other polymer/solvent solutions.

  17. Ceramic vacuum tubes for geothermal well logging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kelly, R.D.

    1977-01-12

    The results of investigations carried out into the availability and suitability of ceramic vacuum tubes for the development of logging tools for geothermal wells are summarized. Design data acquired in the evaluation of ceramic vacuum tubes for the development of a 500/sup 0/C instrumentation amplifier are presented. The general requirements for ceramic vacuum tubes for application to the development of high temperature well logs are discussed. Commercially available tubes are described and future contract activities that specifically relate to ceramic vacuum tubes are detailed. Supplemental data is presented in the appendix. (MHR)

  18. Compressed Air/Vacuum Transportation Techniques

    NASA Astrophysics Data System (ADS)

    Guha, Shyamal

    2011-03-01

    General theory of compressed air/vacuum transportation will be presented. In this transportation, a vehicle (such as an automobile or a rail car) is powered either by compressed air or by air at near vacuum pressure. Four version of such transportation is feasible. In all versions, a ``c-shaped'' plastic or ceramic pipe lies buried a few inches under the ground surface. This pipe carries compressed air or air at near vacuum pressure. In type I transportation, a vehicle draws compressed air (or vacuum) from this buried pipe. Using turbine or reciprocating air cylinder, mechanical power is generated from compressed air (or from vacuum). This mechanical power transferred to the wheels of an automobile (or a rail car) drives the vehicle. In type II-IV transportation techniques, a horizontal force is generated inside the plastic (or ceramic) pipe. A set of vertical and horizontal steel bars is used to transmit this force to the automobile on the road (or to a rail car on rail track). The proposed transportation system has following merits: virtually accident free; highly energy efficient; pollution free and it will not contribute to carbon dioxide emission. Some developmental work on this transportation will be needed before it can be used by the traveling public. The entire transportation system could be computer controlled.

  19. Vaginal delivery of breech presentation.

    PubMed

    Kotaska, Andrew; Menticoglou, Savas; Gagnon, Robert

    2009-06-01

    . At the time of delivery of the after-coming head, an assistant should be present to apply suprapubic pressure to favour flexion and engagement of the fetal head. (II-3B) 18. Spontaneous or assisted breech delivery is acceptable. Fetal traction should be avoided, and fetal manipulation must be applied only after spontaneous delivery to the level of the umbilicus. (III-A) 19. Nuchal arms may be reduced by the Løvset or Bickenbach manoeuvres. (III-B) 20. The fetal head may deliver spontaneously, with the assistance of suprapubic pressure, by Mauriceau-Smellie-Veit manoeuvre, or with the assistance of Piper forceps. (III-B) SETTING AND CONSENT: 21. In the absence of a contraindication to vaginal delivery, a woman with a breech presentation should be informed of the risks and benefits of a trial of labour and elective Caesarean section, and informed consent should be obtained. A woman's choice of delivery mode should be respected. (III-A) 22. The consent discussion and chosen plan should be well documented and communicated to labour-room staff. (III-B) 23. Hospitals offering a trial of labour should have a written protocol for eligibility and intrapartum management. (III-B) 24. Women with a contraindication to a trial of labour should be advised to have a Caesarean section. Women choosing to labour despite this recommendation have a right to do so and should not be abandoned. They should be provided the best possible in-hospital care. (III-A) 25. The Society of Obstetricians and Gynaecologists of Canada (SOGC), in collaboration with the Association of Professors of Obstetrics and Gynaecology (APOG), The College of Family Physicians of Canada (CFPC), and The Canadian Association of Midwives (CAM) should revise the training requirements at the undergraduate and postgraduate levels. SOGC will continue to promote training of current health care providers through the MOREOB, ALARM (Advances in Labour and Risk Management), and other courses. (III-A) 26. Theoretical and hands

  20. Vacuum chamber-free centrifuge with magnetic bearings.

    PubMed

    Park, Cheol Hoon; Kim, Soohyun; Kim, Kyung-Soo

    2013-09-01

    Centrifuges are devices that separate particles of different densities and sizes through the application of a centrifugal force. If a centrifuge could be operated under atmospheric conditions, all vacuum-related components such as the vacuum chamber, vacuum pump, diffusion pump, and sealing could be removed from a conventional centrifuge system. The design and manufacturing procedure for centrifuges could then be greatly simplified to facilitate the production of lightweight centrifuge systems of smaller volume. Furthermore, the maintenance costs incurred owing to wear and tear due to conventional ball bearings would be eliminated. In this study, we describe a novel vacuum chamber-free centrifuge supported by magnetic bearings. We demonstrate the feasibility of the vacuum chamber-free centrifuge by presenting experimental results that verify its high-speed support capability and motoring power capacity.

  1. Vacuum deposition and curing of liquid monomers

    DOEpatents

    Affinito, J.D.

    1993-11-09

    The present invention is the formation of solid polymer layers under vacuum. More specifically, the present invention is the use of standard polymer layer-making equipment that is generally used in an atmospheric environment in a vacuum, and degassing the monomer material prior to injection into the vacuum. Additional layers of polymer or metal may be vacuum deposited onto solid polymer layers. Formation of polymer layers under a vacuum improves material and surface characteristics, and subsequent quality of bonding to additional layers. Further advantages include use of less to no photoinitiator for curing, faster curing, fewer impurities in the polymer electrolyte, as well as improvement in material properties including no trapped gas resulting in greater density, and reduced monomer wetting angle that facilitates spreading of the monomer and provides a smoother finished surface.

  2. Vacuum deposition and curing of liquid monomers

    DOEpatents

    Affinito, J.D.

    1995-03-07

    The present invention is the formation of solid polymer layers under vacuum. More specifically, the present invention is the use of ``standard`` polymer layer-making equipment that is generally used in an atmospheric environment in a vacuum, and degassing the monomer material prior to injection into the vacuum. Additional layers of polymer or metal or oxide may be vacuum deposited onto solid polymer layers. Formation of polymer layers under a vacuum improves material and surface characteristics, and subsequent quality of bonding to additional layers. Further advantages include use of less to no photoinitiator for curing, faster curing, fewer impurities in the polymer electrolyte, as well as improvement in material properties including no trapped gas resulting in greater density, and reduced monomer wetting angle that facilitates spreading of the monomer and provides a smoother finished surface.

  3. Vacuum deposition and curing of liquid monomers

    DOEpatents

    Affinito, John D.

    1993-01-01

    The present invention is the formation of solid polymer layers under vacuum. More specifically, the present invention is the use of "standard" polymer layer-making equipment that is generally used in an atmospheric environment in a vacuum, and degassing the monomer material prior to injection into the vacuum. Additional layers of polymer or metal may be vacuum deposited onto solid polymer layers. Formation of polymer layers under a vacuum improves material and surface characteristics, and subsequent quality of bonding to additional layers. Further advantages include use of less to no photoinitiator for curing, faster curing, fewer impurities in the polymer electrolyte, as well as improvement in material properties including no trapped gas resulting in greater density, and reduced monomer wetting angle that facilitates spreading of the monomer and provides a smoother finished surface.

  4. Vacuum deposition and curing of liquid monomers

    DOEpatents

    Affinito, John D.

    1995-01-01

    The present invention is the formation of solid polymer layers under vacuum. More specifically, the present invention is the use of "standard" polymer layer-making equipment that is generally used in an atmospheric environment in a vacuum, and degassing the monomer material prior to injection into the vacuum. Additional layers of polymer or metal or oxide may be vacuum deposited onto solid polymer layers. Formation of polymer layers under a vacuum improves material and surface characteristics, and subsequent quality of bonding to additional layers. Further advantages include use of less to no photoinitiator for curing, faster curing, fewer impurities in the polymer electrolyte, as well as improvement in material properties including no trapped gas resulting in greater density, and reduced monomer wetting angle that facilitates spreading of the monomer and provides a smoother finished surface.

  5. Cryogenic Insulation System for Soft Vacuum

    NASA Technical Reports Server (NTRS)

    Augustynowicz, S. D.; Fesmire, J. E.

    1999-01-01

    The development of a cryogenic insulation system for operation under soft vacuum is presented in this paper. Conventional insulation materials for cryogenic applications can be divided into three levels of thermal performance, in terms of apparent thermal conductivity [k-value in milliwatt per meter-kelvin (mW/m-K)]. System k-values below 0.1 can be achieved for multilayer insulation operating at a vacuum level below 1 x 10(exp -4) torr. For fiberglass or powder operating below 1 x 10(exp -3) torr, k-values of about 2 are obtained. For foam and other materials at ambient pressure, k-values around 30 are typical. New industry and aerospace applications require a versatile, robust, low-cost thermal insulation with performance in the intermediate range. The target for the new composite insulation system is a k-value below 4.8 mW/m-K (R-30) at a soft vacuum level (from 1 to 10 torr) and boundary temperatures of approximately 77 and 293 kelvin (K). Many combinations of radiation shields, spacers, and composite materials were tested from high vacuum to ambient pressure using cryostat boiloff methods. Significant improvement over conventional systems in the soft vacuum range was demonstrated. The new layered composite insulation system was also shown to provide key benefits for high vacuum applications as well.

  6. Foam-assisted delivery of nanoscale zero valent iron in porous media

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ding, Yuanzhao; Liu, Bo; Shen, Xin

    2013-09-01

    Foam is potentially a promising vehicle to deliver nanoparticles for vadose zone remediation as foam can overcome the intrinsic problems associated with solution-based delivery, such as preferential flow and contaminant mobilization. In this work, the feasibility of using foam to deliver nanoscale zero valent iron (nZVI) in unsaturated porous media was investigated. Foams generated using surfactant sodium lauryl ether sulfate (SLES) showed excellent ability to carry nZVI. SLES and nZVI concentrations in the foaming solutions did not affect the percentages of nZVI concentrations in foams relative to nZVI concentrations in the solutions. When foams carrying nZVI were injected through themore » unsaturated columns, the fractions of nZVI exiting the column were much higher than those when nZVI was injected in liquid. The enhanced nZVI transport implies that foam delivery could significantly increase the radius of influence of injected nZVI. The type and concentrations of surfactants and the influent nZVI concentrations did not noticeably affect nZVI transport during foam delivery. In contrast, nZVI retention increased considerably as the grain size of porous media decreased. Oxidation of foam-delivered nZVI due to oxygen diffusion into unsaturated porous media was visually examined using a flow cell. It was demonstrated that if foams are injected to cover a deep vadose zone layer, oxidation would only cause a small fraction of foam-delivered nZVI to be oxidized before it reacts with contaminants.« less

  7. The impact of Advanced Life Support in Obstetrics (ALSO) training in low-resource countries.

    PubMed

    Dresang, Lee T; González, María Mercedes Ancheta; Beasley, John; Bustillo, Maura Carolina; Damos, Jim; Deutchman, Mark; Evensen, Ann; de Ancheta, Norma González; Rojas-Suarez, José A; Schwartz, Jonathan; Sorensen, Bjarke L; Winslow, Diana; Leeman, Lawrence

    2015-11-01

    To examine the effects of the Advanced Life Support in Obstetrics (ALSO) program on maternal outcomes in four low-income countries. Data were obtained from single-center, longitudinal cohort studies in Colombia, Guatemala, and Honduras, and from an uncontrolled prospective trial in Tanzania. In Colombia, maternal morbidity and the number of near misses increased after ALSO training, but maternal mortality decreased. In Guatemala, sustained reductions in overall maternal mortality and mortality from postpartum hemorrhage (PPH) were recorded after ALSO implementation. In Honduras, there was a significant decrease in episiotomy rates, and increases in active management of the third stage of labor (AMTSL), vacuum-assisted delivery, and reported comfort managing obstetric emergencies. In Tanzania, the frequency of PPH and severe PPH decreased after training, while management improved. In low-income countries, ALSO training was associated with decreased in-hospital maternal mortality, episiotomy use, and PPH. AMTSL and vacuum-assisted vaginal delivery increased in frequency after ALSO training. Copyright © 2015 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  8. Accuracy of self-reported survey data on assisted reproductive technology treatment parameters and reproductive history.

    PubMed

    Stern, Judy E; McLain, Alexander C; Buck Louis, Germaine M; Luke, Barbara; Yeung, Edwina H

    2016-08-01

    It is unknown whether data obtained from maternal self-report for assisted reproductive technology treatment parameters and reproductive history are accurate for use in research studies. We evaluated the accuracy of self-reported in assisted reproductive technology treatment and reproductive history from the Upstate KIDS study in comparison with clinical data reported to the Society for Assisted Reproductive Technology Clinic Outcome Reporting System. Upstate KIDS maternal questionnaire data from deliveries between 2008 and 2010 were linked to data reported to Society for Assisted Reproductive Technology Clinic Outcome Reporting System. The 617 index deliveries were compared as to treatment type (frozen embryo transfer and donor egg or sperm) and use of intracytoplasmic sperm injection and assisted hatching. Use of injectable medications, self-report for assisted reproductive technology, or frozen embryo transfer prior to the index deliveries were also compared. We report agreement in which both sources had yes or both no and sensitivity of maternal report using Society for Assisted Reproductive Technology Clinic Outcome Reporting System as the gold standard. Significance was determined using χ(2) at P < 0.05. Universal agreement was not reached on any parameter but was best for treatment type of frozen embryo transfer (agreement, 96%; sensitivity, 93%) and use of donor eggs (agreement, 97%; sensitivity, 82%) or sperm (agreement, 98%; sensitivity, 82%). Use of intracytoplasmic sperm injection (agreement, 78%: sensitivity, 78%) and assisted hatching (agreement, 57%; sensitivity, 38%) agreed less well with self-reported use (P < .0001). In vitro fertilization (agreement, 82%) and frozen embryo transfer (agreement, 90%) prior to the index delivery were more consistently reported than was use of injectable medication (agreement, 76%) (P < .0001). Women accurately report in vitro fertilization treatment but are less accurate about procedures handled in the

  9. Cryo-Vacuum Testing of the Integrated Science Instrument Module for the James Webb Space Telescope

    NASA Technical Reports Server (NTRS)

    Kimble, Randy A.; Davila, P. S.; Drury, M. P.; Glazer, S. D.; Krom, J. R.; Lundquist, R. A.; Mann, S. D.; McGuffey, D. B.; Perry, R. L.; Ramey, D. D.

    2011-01-01

    With delivery of the science instruments for the James Webb Space Telescope (JWST) to Goddard Space Flight Center (GSFC) expected in 2012, current plans call for the first cryo-vacuum test of the Integrated Science Instrument Module (ISIM) to be carried out at GSFC in early 2013. Plans are well underway for conducting this ambitious test, which will perform critical verifications of a number of optical, thermal, and operational requirements of the IS 1M hardware, at its deep cryogenic operating temperature. We describe here the facilities, goals, methods, and timeline for this important Integration & Test milestone in the JWST program.

  10. Purifying Aluminum by Vacuum Distillation

    NASA Technical Reports Server (NTRS)

    Du Fresne, E. R.

    1985-01-01

    Proposed method for purifying aluminum employs one-step vacuum distillation. Raw material for process impure aluminum produced in electrolysis of aluminum ore. Impure metal melted in vacuum. Since aluminum has much higher vapor pressure than other constituents, boils off and condenses on nearby cold surfaces in proportions much greater than those of other constituents.

  11. Update of Ablative Fractionated Lasers to Enhance Cutaneous Topical Drug Delivery.

    PubMed

    Waibel, Jill S; Rudnick, Ashley; Shagalov, Deborah R; Nicolazzo, Danielle M

    2017-08-01

    Ablative fractional lasers (AFXL) enhance uptake of therapeutics and this newly emerging field is called laser-assisted drug delivery (LAD). This new science has emerged over the past decade and is finding its way into clinical practice. LAD is poised to change how medicine delivers drugs. Topical and systemic application of pharmaceutical agents for therapeutic effect is an integral part of medicine. With topical therapy, the stratum corneum barrier of the skin impairs the ability of drugs to enter the body. The purpose of LAD is to alter the stratum corneum, epidermis, and dermis to facilitate increased penetration of a drug, device, or cell to its respected target. AFXL represents an innovative, non-invasive strategy to overcome the epidermal barrier. LAD employs three steps: (1) breakdown of the skin barrier with a laser, (2) optional use a laser for a therapeutic effect, (3) delivery of the medicine through laser channels to further enhance the therapeutic effect. The advantages of using lasers for drug delivery include the ease of accessibility, the non-invasive aspect, and its effectiveness. By changing the laser settings, one may use LAD to have a drug remain locally within the skin or to have systemic delivery. Many drugs are not intended for use in the dermis and so it has yet to be determined which drugs are appropriate for this technique. It appears this developing technology has the ability to be a new delivery system for both localized and systemic delivery of drugs, cells, and other molecules. With responsible development AFXL-assisted drug delivery may become a new important part of medicine.

  12. Breakdown-Resistant RF Connectors for Vacuum

    NASA Technical Reports Server (NTRS)

    Caro, Edward R.; Bonazza, Walter J.

    1987-01-01

    Resilient inserts compensate for insulation shrinkage. Coaxial-cable connector for radio-frequency (RF) energy resists electrical breakdown in vacuum. Used on RF equipment in vacuum chambers as well as in spaceborne radar and communication gear.

  13. 7 CFR 1488.8 - Documents required after delivery.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Financing of Export Sales of Agricultural Commodities From Private Stocks Under CCC Export Credit Sales Program (GSM-5) Documents Required for Financing § 1488.8 Documents required after delivery. (a) CCC will... regulations within forty-five days, or any extension thereof by the Treasurer or Assistant Treasurer, CCC...

  14. 7 CFR 1488.8 - Documents required after delivery.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Financing of Export Sales of Agricultural Commodities From Private Stocks Under CCC Export Credit Sales Program (GSM-5) Documents Required for Financing § 1488.8 Documents required after delivery. (a) CCC will... regulations within forty-five days, or any extension thereof by the Treasurer or Assistant Treasurer, CCC...

  15. 7 CFR 1488.8 - Documents required after delivery.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Financing of Export Sales of Agricultural Commodities From Private Stocks Under CCC Export Credit Sales Program (GSM-5) Documents Required for Financing § 1488.8 Documents required after delivery. (a) CCC will... regulations within forty-five days, or any extension thereof by the Treasurer or Assistant Treasurer, CCC...

  16. RF assisted Glow Discharge Condition experiment for SST-1 Tokamak

    NASA Astrophysics Data System (ADS)

    Raval, Dilip; Khan, Ziauddin; George, Siju; Dhanani, Kalpeshkumar R.; Paravastu, Yuvakiran; Semwal, Pratibha; Thankey, Prashant; Shoaib Khan, Mohammad; Kakati, Bharat; Pradhan, Subrata

    2017-04-01

    Impurity control reduces the radiation loss from plasma and hence enhances the plasma operation. Oxygen and water vapors are the most common impurities in tokamak devices. Water vapour can be reduced with extensive baking while in order to have a significant reduction in oxygen it is necessary to use glow discharge condition (GDC). RF assisted glow discharge cleaning system will be implemented to remove low z impurities at PFC installed SST-1 vacuum vessel. A RF assisted Glow discharge conditioning is studied at laboratory to find the optimum operating parameters in a view to implement at SST-1 tokamak. Helium is used as a fuel gas in the present experiment. It is observed that the ultimate impurity level is reduced significantly below to the accepted level for plasma operation after RF assisted GDC. The experimental findings of RF assisted Glow discharge conditioning is discussed in details in this paper.

  17. 7 CFR 652.6 - Department delivery of technical services.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 6 2011-01-01 2011-01-01 false Department delivery of technical services. 652.6 Section 652.6 Agriculture Regulations of the Department of Agriculture (Continued) NATURAL RESOURCES... USDA Federal assistance rules and requirements for competency, quality, and selection, as appropriate...

  18. Breather cloth for vacuum curing

    NASA Technical Reports Server (NTRS)

    Reed, M. W.

    1979-01-01

    Finely-woven nylon cloth that has been treated with Teflon improves vacuum adhesive bonding of coatings to substrates. Cloth is placed over coating; entire assembly, including substrate, coating, and cloth, is placed in plastic vacuum bag for curing. Cloth allows coating to "breathe" when bag is evacuated. Applications include bonding film coatings to solar concentrators and collectors.

  19. Vacuum Gas Tungsten Arc Welding

    NASA Technical Reports Server (NTRS)

    Weeks, J. L.; Todd, D. T.; Wooten, J. R.

    1997-01-01

    A two-year program investigated vacuum gas tungsten arc welding (VGTAW) as a method to modify or improve the weldability of normally difficult-to-weld materials. After a vacuum chamber and GTAW power supply were modified, several difficult-to-weld materials were studied and key parameters developed. Finally, Incoloy 903 weld overlays were produced without microfissures.

  20. Multifaceted Applications of Chitosan in Cancer Drug Delivery and Therapy

    PubMed Central

    Babu, Anish; Ramesh, Rajagopal

    2017-01-01

    Chitosan is a versatile polysaccharide of biological origin. Due to the biocompatible and biodegradable nature of chitosan, it is intensively utilized in biomedical applications in scaffold engineering as an absorption enhancer, and for bioactive and controlled drug release. In cancer therapy, chitosan has multifaceted applications, such as assisting in gene delivery and chemotherapeutic delivery, and as an immunoadjuvant for vaccines. The present review highlights the recent applications of chitosan and chitosan derivatives in cancer therapy. PMID:28346381

  1. Apparatus For Metal/Inert-Gas Welding In Vacuum

    NASA Technical Reports Server (NTRS)

    Stocks, C. O.

    1994-01-01

    Metal/inert-gas welding-torch assembly operates in vacuum. Plasma generated in interior chamber and focused onto workpiece in vacuum. Pinch rollers feed wire to weld puddle. Controlled flow of plasma reduces dispersal in vacuum, preventing extinction.

  2. Subgaleal hemorrhage in the newborn infant associated with silicone elastomer vacuum extractor.

    PubMed

    Florentino-Pineda, I; Ezhuthachan, S G; Sineni, L G; Kumar, S P

    1994-01-01

    Subgaleal hemorrhage in the newborn infant has been reported worldwide, but despite the efforts of previous authors, this entity has not received the necessary attention in pediatric literature, and continues to represent a potentially fatal problem. Although the association of subgaleal hemorrhage with the use of the metal cup vacuum extractor has clearly been documented, its association with the silicone elastomer version has not been previously reported. We describe two cases in newborn infants where silicone elastomer cup vacuum extractor was used. The diagnosis of subgaleal hemorrhage must be considered in any infant with a scalp swelling and a falling hematocrit, and coagulation studies should be performed in all infants with a diagnosis of subgaleal hemorrhage. Complications include shock and death if subgaleal hemorrhage is massive and acute, and anemia and hyperbilirubinemia if it is slowly progressive. The familiarity with and ability of care givers to recognize the signs and symptoms of subgaleal hemorrhage are essential in preventing fatalities. A systematic approach to diagnosis with close monitoring of vital signs, hematocrit, blood gases, head circumference, and signs of tissue hypoperfusion is recommended for infants after instrument deliveries. Pathogenesis of this lesion needs to be emphasized in pediatric literature so that early recognition and prompt treatment may avoid a fatal outcome.

  3. Considerations in insulin delivery device selection.

    PubMed

    Valentine, Virginia; Kruger, Davida F

    2010-06-01

    Recent guidelines from the American Diabetes Association and the European Association for the Study of Diabetes promote the use of insulin sooner rather than later in patients with type 2 diabetes to achieve goal range glucose control (< 7%) but remain silent on a recommendation for delivery system. Even though there is widespread consensus among experts and payers that people with type 2 diabetes should use insulin earlier to achieve tight control, it still remains an elusive goal. Benefits of pen-type delivery devices include accurate dosing, faster and easier setting of dose and injection times, and increased patient acceptance and adherence. Before healthcare professionals can recommend a delivery device, it is critical they understand not only the medication in the device but also the various features and benefits to the different devices available and how those impact the patient. We will present considerations to assist in making appropriate device selection, to optimize patient success.

  4. TFTR diagnostic vacuum controller

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Olsen, D.; Persons, R.

    1981-01-01

    The TFTR diagnostic vacuum controller (DVC) provides in conjunction with the Central Instrumentation Control and Data Acquisition System (CICADA), control and monitoring for the pumps, valves and gauges associated with each individual diagnostic vacuum system. There will be approximately 50 systems on TFTR. Two standard versions of the controller (A and B) wil be provided in order to meet the requirements of two diagnostic manifold arrangements. All pump and valve sequencing, as well as protection features, will be implemented by the controller.

  5. Fate of electroweak vacuum during preheating

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ema, Yohei; Mukaida, Kyohei; Nakayama, Kazunori

    2016-10-28

    Our electroweak vacuum may be metastable in light of the current experimental data of the Higgs/top quark mass. If this is really the case, high-scale inflation models require a stabilization mechanism of our vacuum during inflation. A possible candidate is the Higgs-inflaton/-curvature coupling because it induces an additional mass term to the Higgs during the slow roll regime. However, after inflation, the additional mass term oscillates, and it can destabilize our electroweak vacuum via production of large Higgs fluctuations during the inflaton oscillation era. In this paper, we study whether or not the Higgs-inflaton/-curvature coupling can save our vacuum bymore » properly taking account of Higgs production during the preheating stage. We put upper bounds on the Higgs-inflaton and -curvature couplings, and discuss possible dynamics that might relax them.« less

  6. Simulation of the synergistic low Earth orbit effects of vacuum thermal cycling, vacuum UV radiation, and atomic oxygen

    NASA Technical Reports Server (NTRS)

    Dever, Joyce A.; Degroh, Kim K.; Stidham, Curtis R.; Stueber, Thomas J.; Dever, Therese M.; Rodriguez, Elvin; Terlep, Judith A.

    1992-01-01

    In order to assess the low Earth orbit (LEO) durability of candidate space materials, it is necessary to use ground laboratory facilities which provide LEO environmental effects. A facility combining vacuum thermal cycling and vacuum ultraviolet (VUV) radiation has been designed and constructed at NASA Lewis Research Center for this purpose. This facility can also be operated without the VUV lamps. An additional facility can be used to provide VUV exposure only. By utilizing these facilities, followed by atomic oxygen exposure in an RF plasma asher, the effects of the individual vacuum thermal cycling and VUV environments can be compared to the effect of the combined vacuum thermal cycling/VUV environment on the atomic oxygen durability of materials. The synergistic effects of simulated LEO environmental conditions on materials were evaluated by first exposing materials to vacuum thermal cycling, VUV, and vacuum thermal cycling/VUV environments followed by exposure to atomic oxygen in an RP plasma asher. Candidate space power materials such as atomic oxygen protected polyimides and solar concentrator mirrors were evaluated using these facilities. Characteristics of the Vacuum Thermal Cycling/VUV Exposure Facility which simulates the temperature sequences and solar ultraviolet radiation exposure that would be experienced by a spacecraft surface in LEO are discussed. Results of durability evaluations of some candidate space power materials to the simulated LEO environmental conditions will also be discussed. Such results have indicated that for some materials, atomic oxygen durability is affected by previous exposure to thermal cycling and/or VUV exposure.

  7. Nearly Seamless Vacuum-Insulated Boxes

    NASA Technical Reports Server (NTRS)

    Stepanian, Christopher J.; Ou, Danny; Hu, Xiangjun

    2010-01-01

    A design concept, and a fabrication process that would implement the design concept, have been proposed for nearly seamless vacuum-insulated boxes that could be the main structural components of a variety of controlled-temperature containers, including common household refrigerators and insulating containers for shipping foods. In a typical case, a vacuum-insulated box would be shaped like a rectangular parallelepiped conventional refrigerator box having five fully closed sides and a hinged door on the sixth side. Although it is possible to construct the five-closed-side portion of the box as an assembly of five unitary vacuum-insulated panels, it is not desirable to do so because the relatively high thermal conductances of the seams between the panels would contribute significant amounts of heat leakage, relative to the leakage through the panels themselves. In contrast, the proposal would make it possible to reduce heat leakage by constructing the five-closed-side portion of the box plus the stationary portion (if any) of the sixth side as a single, seamless unit; the only remaining seam would be the edge seal around the door. The basic cross-sectional configuration of each side of a vacuum-insulated box according to the proposal would be that of a conventional vacuum-insulated panel: a low-density, porous core material filling a partially evacuated space between face sheets. However, neither the face sheets nor the core would be conventional. The face sheets would be opposite sides of a vacuum bag. The core material would be a flexible polymer-modified silica aerogel of the type described in Silica/Polymer and Silica/Polymer/Fiber Composite Aero - gels (MSC-23736) in this issue of NASA Tech Briefs. As noted in that article, the stiffness of this core material against compression is greater than that of prior aerogels. This is an important advantage because it translates to greater retention of thickness and, hence, of insulation performance when pressure is

  8. Compact vacuum insulation

    DOEpatents

    Benson, D.K.; Potter, T.F.

    1993-01-05

    An ultra-thin compact vacuum insulation panel is comprised of two hard, but bendable metal wall sheets closely spaced apart from each other and welded around the edges to enclose a vacuum chamber. Glass or ceramic spacers hold the wall sheets apart. The spacers can be discrete spherical beads or monolithic sheets of glass or ceramic webs with nodules protruding therefrom to form essentially point'' or line'' contacts with the metal wall sheets. In the case of monolithic spacers that form line'' contacts, two such spacers with the line contacts running perpendicular to each other form effectively point'' contacts at the intersections. Corrugations accommodate bending and expansion, tubular insulated pipes and conduits, and preferred applications are also included.

  9. Compact vacuum insulation

    DOEpatents

    Benson, David K.; Potter, Thomas F.

    1993-01-01

    An ultra-thin compact vacuum insulation panel is comprised of two hard, but bendable metal wall sheets closely spaced apart from each other and welded around the edges to enclose a vacuum chamber. Glass or ceramic spacers hold the wall sheets apart. The spacers can be discrete spherical beads or monolithic sheets of glass or ceramic webs with nodules protruding therefrom to form essentially "point" or "line" contacts with the metal wall sheets. In the case of monolithic spacers that form "line" contacts, two such spacers with the line contacts running perpendicular to each other form effectively "point" contacts at the intersections. Corrugations accommodate bending and expansion, tubular insulated pipes and conduits, and preferred applications are also included.

  10. Investigating steam penetration using thermometric methods in dental handpieces with narrow internal lumens during sterilizing processes with non-vacuum or vacuum processes.

    PubMed

    Winter, S; Smith, A; Lappin, D; McDonagh, G; Kirk, B

    2017-12-01

    Dental handpieces are required to be sterilized between patient use. Vacuum steam sterilization processes with fractionated pre/post-vacuum phases or unique cycles for specified medical devices are required for hollow instruments with internal lumens to assure successful air removal. Entrapped air will compromise achievement of required sterilization conditions. Many countries and professional organizations still advocate non-vacuum sterilization processes for these devices. To investigate non-vacuum downward/gravity displacement, type-N steam sterilization of dental handpieces, using thermometric methods to measure time to achieve sterilization temperature at different handpiece locations. Measurements at different positions within air turbines were undertaken with thermocouples and data loggers. Two examples of widely used UK benchtop steam sterilizers were tested: a non-vacuum benchtop sterilizer (Little Sister 3; Eschmann, Lancing, UK) and a vacuum benchtop sterilizer (Lisa; W&H, Bürmoos, Austria). Each sterilizer cycle was completed with three handpieces and each cycle in triplicate. A total of 140 measurements inside dental handpiece lumens were recorded. The non-vacuum process failed (time range: 0-150 s) to reliably achieve sterilization temperatures within the time limit specified by the international standard (15 s equilibration time). The measurement point at the base of the handpiece failed in all test runs (N = 9) to meet the standard. No failures were detected with the vacuum steam sterilization type B process with fractionated pre-vacuum and post-vacuum phases. Non-vacuum downward/gravity displacement, type-N steam sterilization processes are unreliable in achieving sterilization conditions inside dental handpieces, and the base of the handpiece is the site most likely to fail. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  11. Study on convection improvement of standard vacuum tube

    NASA Astrophysics Data System (ADS)

    He, J. H.; Du, W. P.; Qi, R. R.; He, J. X.

    2017-11-01

    For the standard all-glass vacuum tube collector, enhancing the vacuum tube axial natural convection can improve its thermal efficiency. According to the study of the standard all-glass vacuum tube, three kinds of guide plates which can inhibit the radial convection and increase axial natural convection are designed, and theory model is established. Experiments were carried out on vacuum tubes with three types of baffles and standard vacuum tubes without the improvement. The results show that T-type guide plate is better than that of Y-type guide plate on restraining convection and increasing axial radial convection effect, Y type is better than that of flat plate type, all guide plates are better than no change; the thermal efficiency of the tube was 2.6% higher than that of the unmodified standard vacuum tube. The efficiency of the system in the experiment can be increased by 3.1%.

  12. A gene delivery system containing nuclear localization signal: Increased nucleus import and transfection efficiency with the assistance of RanGAP1.

    PubMed

    Chen, Kang; Guo, Lingling; Zhang, Jiulong; Chen, Qing; Wang, Kuanglei; Li, Chenxi; Li, Weinan; Qiao, Mingxi; Zhao, Xiuli; Hu, Haiyang; Chen, Dawei

    2017-01-15

    In the present report, a degradable gene delivery system (PAMS/DNA/10NLS) containing nucleus location signal peptide (NLS) was prepared. The agarose gel electrophoresis, particle size and zeta potential of PAMS/DNA/10NLS were similar to those of PAMS/DNA, which proved that NLS did not affect the interaction between PAMS and DNA. PAMS/DNA/10NLS exhibited marked extracellular and intracellular degradation under acidic conditions. The degradation was believed to allow NLS to come into contact with importins easily, which was able to mediate the nucleus import. With the help of NLS, PAMS/DNA/10NLS exhibited a higher transfection capability than PAMS/DNA. Moreover, the transfection of PAMS/DNA/10NLS was less dependent on the breakdown of the nucleus envelope than PAMS/DNA. Considering that GTPase-activating protein 1 (RanGAP1) was able to activate the endogenous GTPase, which was necessary for NLS-mediated nucleus import, RanGAP1 overexpressed cells (RanGAP1 cells) were produced. This result showed that RanGAP1 cells had higher GTPase activities than normal cells. Both the nucleus import and transfection efficiency of PAMS/DNA/10NLS were markedly higher in RanGAP1 cells than that in normal cells. The in vivo transfection results also showed that the transfection efficiency of PAMS/DNA/10NLS was higher in RanGAP1 pre-treated mice than that in normal mice. These findings showed that PAMS/DNA/10NLS is a promising gene delivery system with the assistance of RanGAP1. The present report describes the increased transfection efficiency of a degradable gene delivery system (PAMS/DNA/10NLS) containing nuclear location signal (NLS) with the assistance of GTPase-activating protein 1 (RanGAP1). The physicochemical properties of PAMS/DNA/10NLS were similar to those of PAMS/DNA. PAMS/DNA/10NLS exhibited great extracellular and intracellular degradations, which might allow NLS to contact with importins easily. With the help of NLS, PAMS/DNA/10NLS exhibited a higher transfection

  13. 14 CFR 25.1433 - Vacuum systems.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Vacuum systems. 25.1433 Section 25.1433 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Miscellaneous Equipment § 25.1433 Vacuum systems. There...

  14. Plates for vacuum thermal fusion

    DOEpatents

    Davidson, James C.; Balch, Joseph W.

    2002-01-01

    A process for effectively bonding arbitrary size or shape substrates. The process incorporates vacuum pull down techniques to ensure uniform surface contact during the bonding process. The essence of the process for bonding substrates, such as glass, plastic, or alloys, etc., which have a moderate melting point with a gradual softening point curve, involves the application of an active vacuum source to evacuate interstices between the substrates while at the same time providing a positive force to hold the parts to be bonded in contact. This enables increasing the temperature of the bonding process to ensure that the softening point has been reached and small void areas are filled and come in contact with the opposing substrate. The process is most effective where at least one of the two plates or substrates contain channels or grooves that can be used to apply vacuum between the plates or substrates during the thermal bonding cycle. Also, it is beneficial to provide a vacuum groove or channel near the perimeter of the plates or substrates to ensure bonding of the perimeter of the plates or substrates and reduce the unbonded regions inside the interior region of the plates or substrates.

  15. Researches on Position Detection for Vacuum Switch Electrode

    NASA Astrophysics Data System (ADS)

    Dong, Huajun; Guo, Yingjie; Li, Jie; Kong, Yihan

    2018-03-01

    Form and transformation character of vacuum arc is important influencing factor on the vacuum switch performance, and the dynamic separations of electrode is the chief effecting factor on the transformation of vacuum arcs forms. Consequently, how to detect the position of electrode to calculate the separations in the arcs image is of great significance. However, gray level distribution of vacuum arcs image isn’t even, the gray level of burning arcs is high, but the gray level of electrode is low, meanwhile, the forms of vacuum arcs changes sharply, the problems above restrict electrode position detection precisely. In this paper, algorithm of detecting electrode position base on vacuum arcs image was proposed. The digital image processing technology was used in vacuum switch arcs image analysis, the upper edge and lower edge were detected respectively, then linear fitting was done using the result of edge detection, the fitting result was the position of electrode, thus, accurate position detection of electrode was realized. From the experimental results, we can see that: algorithm described in this paper detected upper and lower edge of arcs successfully and the position of electrode was obtained through calculation.

  16. Advanced Photon Source accelerator ultrahigh vacuum guide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, C.; Noonan, J.

    1994-03-01

    In this document the authors summarize the following: (1) an overview of basic concepts of ultrahigh vacuum needed for the APS project, (2) a description of vacuum design and calculations for major parts of APS, including linac, linac waveguide, low energy undulator test line, positron accumulator ring (PAR), booster synchrotron ring, storage ring, and insertion devices, and (3) cleaning procedures of ultrahigh vacuum (UHV) components presently used at APS.

  17. Ceramic vacuum tubes for geothermal well logging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kelly, R.D.

    1977-01-01

    Useful design data acquired in the evaluation of ceramic vacuum tubes for the development of a 500/sup 0/C instrumentation amplifier are presented. The general requirements for ceramic vacuum tubes are discussed for application to the development of high temperature well logs. Commercially available tubes are described and future contract activities that specifically relate to ceramic vacuum tubes are detailed. Supplemental data are presented in the appendix.

  18. 46 CFR 105.10-20 - Pressure vacuum relief valve.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Pressure vacuum relief valve. (a) The term pressure vacuum relief valve means any device or assembly of a mechanical, liquid, weight, or other type used for the automatic regulation of pressure or vacuum in enclosed... 46 Shipping 4 2011-10-01 2011-10-01 false Pressure vacuum relief valve. 105.10-20 Section 105.10...

  19. 46 CFR 105.10-20 - Pressure vacuum relief valve.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Pressure vacuum relief valve. (a) The term pressure vacuum relief valve means any device or assembly of a mechanical, liquid, weight, or other type used for the automatic regulation of pressure or vacuum in enclosed... 46 Shipping 4 2010-10-01 2010-10-01 false Pressure vacuum relief valve. 105.10-20 Section 105.10...

  20. 46 CFR 105.10-20 - Pressure vacuum relief valve.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Pressure vacuum relief valve. (a) The term pressure vacuum relief valve means any device or assembly of a mechanical, liquid, weight, or other type used for the automatic regulation of pressure or vacuum in enclosed... 46 Shipping 4 2014-10-01 2014-10-01 false Pressure vacuum relief valve. 105.10-20 Section 105.10...

  1. 46 CFR 105.10-20 - Pressure vacuum relief valve.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Pressure vacuum relief valve. (a) The term pressure vacuum relief valve means any device or assembly of a mechanical, liquid, weight, or other type used for the automatic regulation of pressure or vacuum in enclosed... 46 Shipping 4 2012-10-01 2012-10-01 false Pressure vacuum relief valve. 105.10-20 Section 105.10...

  2. 46 CFR 105.10-20 - Pressure vacuum relief valve.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Pressure vacuum relief valve. (a) The term pressure vacuum relief valve means any device or assembly of a mechanical, liquid, weight, or other type used for the automatic regulation of pressure or vacuum in enclosed... 46 Shipping 4 2013-10-01 2013-10-01 false Pressure vacuum relief valve. 105.10-20 Section 105.10...

  3. 7 CFR 58.913 - Evaporators and vacuum pans.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Evaporators and vacuum pans. 58.913 Section 58.913....913 Evaporators and vacuum pans. All equipment used in the removal of moisture from milk or milk... Sanitary Standards for Milk and Milk Products Evaporators and Vacuum Pans. ...

  4. 7 CFR 58.913 - Evaporators and vacuum pans.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 3 2014-01-01 2014-01-01 false Evaporators and vacuum pans. 58.913 Section 58.913....913 Evaporators and vacuum pans. All equipment used in the removal of moisture from milk or milk... Sanitary Standards for Milk and Milk Products Evaporators and Vacuum Pans. ...

  5. 7 CFR 58.913 - Evaporators and vacuum pans.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Evaporators and vacuum pans. 58.913 Section 58.913....913 Evaporators and vacuum pans. All equipment used in the removal of moisture from milk or milk... Sanitary Standards for Milk and Milk Products Evaporators and Vacuum Pans. ...

  6. 7 CFR 58.913 - Evaporators and vacuum pans.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Evaporators and vacuum pans. 58.913 Section 58.913....913 Evaporators and vacuum pans. All equipment used in the removal of moisture from milk or milk... Sanitary Standards for Milk and Milk Products Evaporators and Vacuum Pans. ...

  7. 7 CFR 58.913 - Evaporators and vacuum pans.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 3 2012-01-01 2012-01-01 false Evaporators and vacuum pans. 58.913 Section 58.913....913 Evaporators and vacuum pans. All equipment used in the removal of moisture from milk or milk... Sanitary Standards for Milk and Milk Products Evaporators and Vacuum Pans. ...

  8. Vacuum coupling of rotating superconducting rotor

    DOEpatents

    Shoykhet, Boris A.; Zhang, Burt Xudong; Driscoll, David Infante

    2003-12-02

    A rotating coupling allows a vacuum chamber in the rotor of a superconducting electric motor to be continually pumped out. The coupling consists of at least two concentric portions, one of which is allowed to rotate and the other of which is stationary. The coupling is located on the non-drive end of the rotor and is connected to a coolant supply and a vacuum pump. The coupling is smaller in diameter than the shaft of the rotor so that the shaft can be increased in diameter without having to increase the size of the vacuum seal.

  9. Computer Assistance for Writing Interactive Programs: TICS.

    ERIC Educational Resources Information Center

    Kaplow, Roy; And Others

    1973-01-01

    Investigators developed an on-line, interactive programing system--the Teacher-Interactive Computer System (TICS)--to provide assistance to those who were not programers, but nevertheless wished to write interactive instructional programs. TICS had two components: an author system and a delivery system. Underlying assumptions were that…

  10. A Novel Nonviral Gene Delivery System: Multifunctional Envelope-Type Nano Device

    NASA Astrophysics Data System (ADS)

    Hatakeyama, Hiroto; Akita, Hidetaka; Kogure, Kentaro; Harashima, Hideyoshi

    In this review we introduce a new concept for developing a nonviral gene delivery system which we call "Programmed Packaging." Based on this concept, we succeeded in developing a multifunctional envelope-type nano device (MEND), which exerts high transfection activities equivalent to those of an adenovirus in a dividing cell. The use of MEND has been extended to in vivo applications. PEG/peptide/DOPE ternary conjugate (PPD)-MEND, a new in vivo gene delivery system for the targeting of tumor cells that dissociates surface-modified PEG in tumor tissue by matrix metalloproteinase (MMP) and exerts significant transfection activities, was developed. In parallel with the development of MEND, a quantitative gene delivery system, Confocal Image-assisted 3-dimensionally integrated quantification (CIDIQ), also was developed. This method identified the rate-limiting step of the nonviral gene delivery system by comparing it with adenoviral-mediated gene delivery. The results of this analysis provide a new direction for the development of rational nonviral gene delivery systems.

  11. In-Vacuum Dissociator for Atomic-Hydrogen Masers

    NASA Technical Reports Server (NTRS)

    Vessot, R. F.

    1987-01-01

    Thermal control and vacuum sealing achieved while contamination avoided. Simple, relatively inexpensive molecular-hydrogen dissociator for atomic-hydrogen masers used on Earth or in vacuum of space. No air cooling required, and absence of elastomeric O-ring seals prevents contamination. In-vacuum dissociator for atomic hydrogen masers, hydrogen gas in glass dissociator dissociated by radio-frequency signal transmitted from surrounding 3-turn coil. Heat in glass conducted away by contacting metal surfaces.

  12. Vacuum-jacketed transfer line installation technique

    NASA Technical Reports Server (NTRS)

    Bowers, W. M.

    1968-01-01

    Rolling-type spacers in the form of steel balls retained in appropriate sleeves affixed at intervals to the exterior of the transfer line facilitate the installation of a vacuum-jacketed line. They act as standoffs to position the transfer line concentrically within the vacuum jacket line.

  13. Socio-demographic determinants of skilled birth attendant at delivery in rural southern Ghana.

    PubMed

    Manyeh, Alfred Kwesi; Akpakli, David Etsey; Kukula, Vida; Ekey, Rosemond Akepene; Narh-Bana, Solomon; Adjei, Alexander; Gyapong, Margaret

    2017-07-11

    Maternal mortality is the subject of the United Nations' fifth Millennium Development Goal, which is to reduce the maternal mortality ratio by three quarters from 1990 to 2015. The giant strides made by western countries in dropping of their maternal mortality ratio were due to the recognition given to skilled attendants at delivery. In Ghana, nine in ten mothers receive antenatal care from a health professional whereas only 59 and 68% of deliveries are assisted by skilled personnel in 2008 and 2010 respectively. This study therefore examines the determinants of skilled birth attendant at delivery in rural southern Ghana. This study comprises of 1874 women of reproductive age who had given birth 2 years prior to the study whose information were extracted from the Dodowa Health and Demographic Surveillance System. The univariable and multivariable associations between exposure variables (risk factors) and skilled birth attendant at delivery were explored using logistic regression. Out of a total of 1874 study participants, 98.29% of them receive antenatal care services during pregnancy and only 68.89% were assisted by skilled person at their last delivery prior to the survey. The result shows a remarkable influence of maternal age, level of education, parity, socioeconomic status and antenatal care attendance on skilled attendants at delivery. Although 69% of women in the study had skilled birth attendants at delivery, women from poorest households, higher parity, uneducated, and not attending antenatal care and younger women were more likely to deliver without a skilled birth attendants at delivery. Future intervention in the study area to bridge the gap between the poor and least poor women, improve maternal health and promote the use of skilled birth at delivery is recommended.

  14. Thermodynamic performance of multi-stage gradational lead screw vacuum pump

    NASA Astrophysics Data System (ADS)

    Zhao, Fan; Zhang, Shiwei; Sun, Kun; Zhang, Zhijun

    2018-02-01

    As a kind of dry mechanical vacuum pump, the twin-screw vacuum pump has an outstanding pumping performance during operation, widely used in the semiconductor industry. Compared with the constant lead screw (CLS) vacuum pump, the gradational lead screw (GLS) vacuum pump is more popularly applied in recent years. Nevertheless, not many comparative studies on the thermodynamic performance of GLS vacuum pump can be found in the literature. Our study focuses on one type of GLS vacuum pump, the multi-stage gradational lead screw (MGLS) vacuum pump, gives a detailed description of its construction and illustrates it with the drawing. Based on the structural analysis, the thermodynamic procedure is divided into four distinctive processes, including sucking process, transferring (compressing) process, backlashing process and exhausting process. The internal mechanism of each process is qualitatively illustrated and the mathematical expressions of seven thermodynamic parameters are given under the ideal situation. The performance curves of MGLS vacuum pump are plotted by MATLAB software and compared with those of the CLS vacuum pump in the same case. The results can well explain why the MGLS vacuum pump has more favorable pumping performance than the CLS vacuum pump in saving energy, reducing noise and heat dissipation.

  15. Vacuum tool manipulator

    DOEpatents

    Zollinger, William T.

    1993-01-01

    Apparatus for manipulating a vacuum hose in a reactor vessel comprises a housing with two opposing openings, an arm carried by the housing and deployable from a stowed position essentially completely within the housing to an extended position where the arm extends through the two openings in a generally horizontal position. The arm preferably has a two-fingered gripping device for gripping the vacuum hose but may carry a different end effector such as a grinding wheel. The fingers are opened and closed by one air cylinder. A second air cylinder extends the device. A third air cylinder within the housing pivotally pulls the opposing end of the arm into the housing via a pivoting member pivotally connected between the third air cylinder shaft and the arm.

  16. REVIEWS OF TOPICAL PROBLEMS: Cosmic vacuum

    NASA Astrophysics Data System (ADS)

    Chernin, Artur D.

    2001-11-01

    Recent observational studies of distant supernovae have suggested the existence of cosmic vacuum whose energy density exceeds the total density of all the other energy components in the Universe. The vacuum produces the field of antigravity that causes the cosmological expansion to accelerate. It is this accelerated expansion that has been discovered in the observations. The discovery of cosmic vacuum radically changes our current understanding of the present state of the Universe. It also poses new challenges to both cosmology and fundamental physics. Why is the density of vacuum what it is? Why do the densities of the cosmic energy components differ in exact value but agree in order of magnitude? On the other hand, the discovery made at large cosmological distances of hundreds and thousands Mpc provides new insights into the dynamics of the nearby Universe, the motions of galaxies in the local volume of 10 - 20 Mpc where the cosmological expansion was originally discovered.

  17. Source replenishment device for vacuum deposition

    DOEpatents

    Hill, Ronald A.

    1988-01-01

    A material source replenishment device for use with a vacuum deposition apparatus. The source replenishment device comprises an intermittent motion producing gear arrangement disposed within the vacuum deposition chamber. An elongated rod having one end operably connected to the gearing arrangement is provided with a multiarmed head at the opposite end disposed adjacent the heating element of the vacuum deposition apparatus. An inverted U-shaped source material element is releasably attached to the outer end of each arm member whereby said multiarmed head is moved to locate a first of said material elements above said heating element, whereupon said multiarmed head is lowered to engage said material element with the heating element and further lowered to release said material element on the heating element. After vaporization of said material element, second and subsequent material elements may be provided to the heating element without the need for opening the vacuum deposition apparatus to the atmosphere.

  18. Source replenishment device for vacuum deposition

    DOEpatents

    Hill, R.A.

    1986-05-15

    A material source replenishment device for use with a vacuum deposition apparatus is described. The source replenishment device comprises an intermittent motion producing gear arrangement disposed within the vacuum deposition chamber. An elongated rod having one end operably connected to the gearing arrangement is provided with a multiarmed head at the opposite end disposed adjacent the heating element of the vacuum deposition apparatus. An inverted U-shaped source material element is releasably attached to the outer end of each arm member whereby said multiarmed head is moved to locate a first of said material elements above said heating element, whereupon said multiarmed head is lowered to engage said material element with the heating element and further lowered to release said material element on the heating element. After vaporization of said material element, second and subsequent material elements may be provided to the heating element without the need for opening the vacuum deposition apparatus to the atmosphere.

  19. Waveguide quantum electrodynamics in squeezed vacuum

    NASA Astrophysics Data System (ADS)

    You, Jieyu; Liao, Zeyang; Li, Sheng-Wen; Zubairy, M. Suhail

    2018-02-01

    We study the dynamics of a general multiemitter system coupled to the squeezed vacuum reservoir and derive a master equation for this system based on the Weisskopf-Wigner approximation. In this theory, we include the effect of positions of the squeezing sources which is usually neglected in the previous studies. We apply this theory to a quasi-one-dimensional waveguide case where the squeezing in one dimension is experimentally achievable. We show that while dipole-dipole interaction induced by ordinary vacuum depends on the emitter separation, the two-photon process due to the squeezed vacuum depends on the positions of the emitters with respect to the squeezing sources. The dephasing rate, decay rate, and the resonance fluorescence of the waveguide-QED in the squeezed vacuum are controllable by changing the positions of emitters. Furthermore, we demonstrate that the stationary maximum entangled NOON state for identical emitters can be reached with arbitrary initial state when the center-of-mass position of the emitters satisfies certain conditions.

  20. Development of PMMA membranes functionalized with hydroxypropyl-beta-cyclodextrins for controlled drug delivery using a supercritical CO(2)-assisted technology.

    PubMed

    Temtem, M; Pompeu, D; Jaraquemada, G; Cabrita, E J; Casimiro, T; Aguiar-Ricardo, A

    2009-07-06

    Cyclodextrin-containing polymers have proved themselves to be useful for controlled release. Herein we describe the preparation of membranes of poly(methylmethacrylate) (PMMA) containing hydroxypropyl-beta-cyclodextrins (HP-beta-CDs) using a supercritical CO(2)-assisted phase inversion method, for potential application as drug delivery devices. Results are reported on the membrane preparation, physical properties, and drug elution profile of a model drug. The polymeric membranes were obtained with HP-beta-CD contents ranging from 0 to 33.4 wt%, by changing the composition of the casting solution, and were further impregnated with ibuprofen using supercritical carbon dioxide (scCO(2)) in batch mode. The influence of the membrane functionalization in the controlled release of ibuprofen was studied by performing in vitro experiments in buffer solution pH at 7.4. The release of the anti-inflammatory drug could be tuned by varying the cyclodextrin content on the membranes.

  1. Sugar maple sap volume increases as vacuum level is increased

    Treesearch

    Russell S. Walters; H. Clay Smith

    1975-01-01

    Maple sap yields collected by using plastic tubing with a vacuum pump increased as the vacuum level was increased. Sap volumes collected at the 10- and 15-inch mercury vacuum levels were statistically significantly higher than volumes collected at the 5-inch level. Although the 15-inch vacuum yielded more sap than the 10-inch vacuum, the difference was not...

  2. Characteristics Associated With Severe Perineal and Cervical Lacerations During Vaginal Delivery

    PubMed Central

    Landy, Helain J.; Laughon, S. Katherine; Bailit, Jennifer; Kominiarek, Michelle A.; Gonzalez-Quintero, Victor Hugo; Ramirez, Mildred; Haberman, Shoshana; Hibbard, Judith; Wilkins, Isabelle; Branch, D. Ware; Burkman, Ronald T.; Gregory, Kimberly; Hoffman, Matthew K.; Learman, Lee A.; Hatjis, Christos; VanVeldhuisen, Paul C.; Reddy, Uma M.; Troendle, James; Sun, Liping; Zhang, Jun

    2011-01-01

    Objective To characterize potentially modifiable risk factors for third- or fourth-degree perineal lacerations and cervical lacerations in a contemporary U.S. obstetric practice. Methods The Consortium on Safe Labor collected electronic medical records from 19 hospitals within 12 institutions (228,668 deliveries from 2002 to 2008). Information on patient characteristics, prenatal complications, labor and delivery data, and maternal and neonatal outcomes were collected. Only women with successful vaginal deliveries of cephalic singletons at 34 weeks of gestation or later were included; we excluded data from sites lacking information about lacerations at delivery and deliveries complicated by shoulder dystocia; 87,267 and 71,170 women were analyzed for third- or fourth-degree and cervical lacerations, respectively. Multivariable logistic regressions were used to adjust for other factors. Results Third- or fourth-degree lacerations occurred in 2,516 women (2,223 nulliparous [5.8%], 293 [0.6%] multiparous) and cervical lacerations occurred in 536 women (324 nulliparous [1.1%], 212 multiparous [0.5%]). Risks for third or fourth-degree lacerations included nulliparity (7.2-fold risk), being Asian or Pacific Islander, increasing birth weight, operative vaginal delivery, episiotomy, and longer second stage of labor. Increasing body mass index was associated with fewer lacerations. Risk factors for cervical lacerations included young maternal age, vacuum vaginal delivery, and oxytocin use among multiparous women, and cerclage regardless of parity. Conclusion Our large cohort of women with severe obstetric lacerations reflects contemporary obstetric practices. Nulliparity and episiotomy use are important risk factors for third- or fourth-degree lacerations. Cerclage increases the risk for cervical lacerations. Many identified risk factors may not be modifiable. PMID:21343766

  3. Outgassing of solid material into vacuum thermal insulation spaces

    NASA Technical Reports Server (NTRS)

    Wang, Pao-Lien

    1994-01-01

    Many cryogenic storage tanks use vacuum between inner and outer tank for thermal insulation. These cryogenic tanks also use a radiation shield barrier in the vacuum space to prevent radiation heat transfer. This shield is usually constructed by using multiple wraps of aluminized mylar and glass paper as inserts. For obtaining maximum thermal performance, a good vacuum level must be maintained with the insulation system. It has been found that over a period of time solid insulation materials will vaporize into the vacuum space and the vacuum will degrade. In order to determine the degradation of vacuum, the rate of outgassing of the insulation materials must be determined. Outgassing rate of several insulation materials obtained from literature search were listed in tabular form.

  4. Mass spectrometer vacuum housing and pumping system

    DOEpatents

    Coutts, G.W.; Bushman, J.F.; Alger, T.W.

    1996-07-23

    A vacuum housing and pumping system is described for a portable gas chromatograph/mass spectrometer (GC/MS). The vacuum housing section of the system has minimum weight for portability while designed and constructed to utilize metal gasket sealed stainless steel to be compatible with high vacuum operation. The vacuum pumping section of the system consists of a sorption (getter) pump to remove atmospheric leakage and outgassing contaminants as well as the gas chromatograph carrier gas (hydrogen) and an ion pump to remove the argon from atmospheric leaks. The overall GC/MS system has broad application to contaminants, hazardous materials, illegal drugs, pollution monitoring, etc., as well as for use by chemical weapon treaty verification teams, due to the light weight and portability thereof. 7 figs.

  5. Mass spectrometer vacuum housing and pumping system

    DOEpatents

    Coutts, Gerald W.; Bushman, John F.; Alger, Terry W.

    1996-01-01

    A vacuum housing and pumping system for a portable gas chromatograph/mass spectrometer (GC/MS). The vacuum housing section of the system has minimum weight for portability while designed and constructed to utilize metal gasket sealed stainless steel to be compatible with high vacuum operation. The vacuum pumping section of the system consists of a sorption (getter) pump to remove atmospheric leakage and outgassing contaminants as well as the gas chromatograph carrier gas (hydrogen) and an ion pump to remove the argon from atmospheric leaks. The overall GC/MS system has broad application to contaminants, hazardous materials, illegal drugs, pollution monitoring, etc., as well as for use by chemical weapon treaty verification teams, due to the light weight and portability thereof.

  6. Viability of Cladosporium herbarum spores under 157 nm laser and vacuum ultraviolet irradiation, low temperature (10 K) and vacuum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sarantopoulou, E., E-mail: esarant@eie.gr; Stefi, A.; Kollia, Z.

    Ultraviolet photons can damage microorganisms, which rarely survive prolonged irradiation. In addition to the need for intact DNA, cell viability is directly linked to the functionality of the cell wall and membrane. In this work, Cladosporium herbarum spore monolayers exhibit high viability (7%) when exposed to 157 nm laser irradiation (412 kJm⁻²) or vacuum-ultraviolet irradiation (110–180 nm) under standard pressure and temperature in a nitrogen atmosphere. Spore viability can be determined by atomic-force microscopy, nano-indentation, mass, μ-Raman and attenuated reflectance Fourier-transform far-infrared spectroscopies and DNA electrophoresis. Vacuum ultraviolet photons cause molecular damage to the cell wall, but radiation resistance inmore » spores arises from the activation of a photon-triggered signaling reaction, expressed via the exudation of intracellular substances, which, in combination with the low penetration depth of vacuum-ultraviolet photons, shields DNA from radiation. Resistance to phototoxicity under standard conditions was assessed, as was resistance to additional environmental stresses, including exposure in a vacuum, under different rates of change of pressure during pumping time and low (10 K) temperatures. Vacuum conditions were far more destructive to spores than vacuum-ultraviolet irradiation, and UV-B photons were two orders of magnitude more damaging than vacuum-ultraviolet photons. The viability of irradiated spores was also enhanced at 10 K. This work, in addition to contributing to the photonic control of the viability of microorganisms exposed under extreme conditions, including decontamination of biological warfare agents, outlines the basis for identifying bio-signaling in vivo using physical methodologies.« less

  7. Main Vacuum Technical Issues of Evacuated Tube Transportation

    NASA Astrophysics Data System (ADS)

    Zhang, Y. P.; Li, S. S.; Wang, M. X.

    In the future, Evacuated Tube Transportation (ETT) would be built and faster than jets. ETT tube with diameter 2∼4m and length over 1000 km will be the largest scale vacuum equipment on earth. This paper listed some main vacuum technical issues to be solved in ETT as follow. How to build ultra-large-scale vacuum chamber like ETT tube with low cost and high reliability? How to pump gas out off the ETT tube in short time? How to release heat or reduce temperature in the vacuum tube? Hot to avoid vacuum electricity discharge? How to manufacture vehicles with airproof shells and equip the life support system? How to detect leakage and find leakage position efficiently and fast as possible? Some relative solutions and suggestions are put up.

  8. Vacuum deposition and curing of liquid monomers apparatus

    DOEpatents

    Affinito, John D.

    1996-01-01

    The present invention is the formation of solid polymer layers under vacuum. More specifically, the present invention is the use of "standard" polymer layer-making equipment that is generally used in an atmospheric environment in a vacuum, and degassing the monomer material prior to injection into the vacuum. Additional layers of polymer or metal or oxide may be vacuum deposited onto solid polymer layers. Formation of polymer layers under a vacuum improves material and surface characteristics, and subsequent quality of bonding to additional layers. Further advantages include use of less to no photoinitiator for curing, faster curing, fewer impurities in the polymer electrolyte, as well as improvement in material properties including no trapped gas resulting in greater density, and reduced monomer wetting angle that facilitates spreading of the monomer and provides a smoother finished surface.

  9. Development of a MEMS-Scale Turbomachinery Based Vacuum Pump

    DTIC Science & Technology

    2012-06-01

    MEMS -SCALE TURBOMACHINERY BASED VACUUM PUMP by Michael J. Shea June 2012 Thesis Advisor: Anthony J. Gannon Second Reader...June 2012 3. REPORT TYPE AND DATES COVERED Master’s Thesis 4. TITLE AND SUBTITLE Development of a MEMS -Scale Turbomachinery Based Vacuum Pump 5...to develop a MEMS scale turbomachinery based vacuum pump. This would allow very high vacuum to be drawn for handheld mass spectroscopy. This

  10. Randomized controlled trial of stereotactic 11-G vacuum-assisted core biopsy for the diagnosis and management of mammographic microcalcification

    PubMed Central

    Maxwell, Anthony J; Morris, Julie; Lim, Yit Y; Harake, MD Janick; Whiteside, Sigrid

    2016-01-01

    Objective: To compare the accuracy of 11-G vacuum-assisted biopsy (VAB) with 14-G core needle biopsy (CNB) to diagnose mammographic microcalcification (MM) and effect on surgical outcomes. Methods: Following ethical approval, VAB and CNB (control) were compared in a randomized prospective study for first-line diagnosis of MM and subsequent surgical outcomes in two breast-screening units. Participants gave written informed consent. Exclusions included comorbidity precluding surgery, prior ipsilateral breast cancer and lesions >40 mm requiring mastectomy as first surgical procedure. The final pathological diagnosis was compared with the initial biopsy result. Quality-of-life (QOL) questionnaires were administered at baseline, 2, 6 and 12 months. 110 participants were required to show a 25% improvement in diagnosis with VAB compared with CNB (90% power). Results: Eligibility was assessed for 787 cases; 129 females recalled from the National Health Service breast screening programme were randomized. Diagnostic accuracy of VAB was 86% and that of CNB was 84%. Using VAB, 2/14 (14.3%) cases upgraded from ductal carcinoma in situ to invasion at surgery and 3/19 (15.8%) using CNB. Following VAB 7/16 (44%) cases required repeat surgery vs 7/24 (29%) after CNB. Both groups recorded significant worsening of functional QOL measures and increased breast pain at follow-up. Conclusion: VAB and CNB were equally accurate at diagnosing MM, and no significant differences in surgical outcomes were observed. Advances in knowledge: The first randomized controlled study of VAB for diagnosis of microcalcification using digital mammography showed no difference in diagnostic accuracy of VAB and CNB, or in the proportion of participants needing repeat non-operative biopsy or second therapeutic operation to treat malignancy. PMID:26654214

  11. Vacuum system for the SAMURAI spectrometer

    NASA Astrophysics Data System (ADS)

    Shimizu, Y.; Otsu, H.; Kobayashi, T.; Kubo, T.; Motobayashi, T.; Sato, H.; Yoneda, K.

    2013-12-01

    The first commissioning experiment of the SAMURAI spectrometer and its beam line was performed in March, 2012. The vacuum system for the SAMURAI spectrometer includes its beam line and the SAMURAI vacuum chamber with the windows for detecting neutrons and charged particles. The window for neutrons was made of stainless steel with a thickness of 3 mm and was designed with a shape of partial cylinder to support itself against the atmospheric pressure. The window for charged particles was of the combination of Kevlar and Mylar with the thickness of 280 and 75 μm, respectively. The pressure in the vacuum system was at a few Pa throughout the commissioning experiment.

  12. Moving characteristics of electrodes for vacuum circuit breaker

    NASA Astrophysics Data System (ADS)

    Yuan, Shun; Wang, Jimei

    1994-05-01

    This paper analyzes the effect of the gap of electrodes on the state of vacuum arc by experiment and theory. And the model of vacuum arc is set up. The optimal gap can be deduced from controlling the vacuum arc to be diffusion state, in order to get the optimal moving characteristics of electrodes.

  13. Three stage vacuum system for ultralow temperature installation

    NASA Astrophysics Data System (ADS)

    Das, N. K.; Pradhan, J.; Naser, Md Z. A.; Mandal, B. Ch; Roy, A.; Kumar, P.; Mallik, C.; Bhandari, R. K.

    2012-11-01

    We use a three stage vacuum system for developing a dilution fridge at VECC, Kolkata. We aim at achieving a cooling power of 20μW at 100mK for various experiments especially in the field of condensed matter and nuclear physics. The system is essentially composed of four segments-bath cryostat, vacuum system, dilution insert and 3He circulation circuit. Requirement of vacuum system at different stages are different. The vacuum system for cryostat and for internal vacuum chamber located within the helium bath is a common turbo molecular pump backed by scroll pump as to maintain a vacuum ~10-6mbar. For bringing down the temperature of the helium evaporator, we use a high throughput Roots pump backed by a dry pump. The pumping system for 3He distillation chamber (still) requires a high pumping speed, so a turbo drag pump backed by a scroll pump has been installed. As the fridge use precious 3He gas for operation, the entire system has been made to be absolutely leak proof with respect to the 3He gas.

  14. Carbon nanotubes based vacuum gauge

    NASA Astrophysics Data System (ADS)

    Rudyk, N. N.; Il'in, O. I.; Il'ina, M. V.; Fedotov, A. A.; Klimin, V. S.; Ageev, O. A.

    2017-11-01

    We have created an ionization type Vacuum gauge with sensor element based on an array of vertically aligned carbon nanotubes. Obtained asymmetrical current-voltage characteristics at different voltage polarity on the electrode with the CNTs. It was found that when applying a negative potential on an electrode with the CNTs, the current in the gap is higher than at a positive potential. In the pressure range of 1 ÷ 103 Torr vacuum gauge sensitivity was 6 mV/Torr (at a current of 4.5·10-5 A) and in the range of 10-5 ÷ 1 Torr was 10 mV/Torr (at a current of 1.3·10-5 A). It is shown that the energy efficiency of vacuum gauge can be increased in the case where electrode with CNT operates as an emitter of electrons.

  15. Baryogenesis in false vacuum

    NASA Astrophysics Data System (ADS)

    Hamada, Yuta; Yamada, Masatoshi

    2017-09-01

    The null result in the LHC may indicate that the standard model is not drastically modified up to very high scales, such as the GUT/string scale. Having this in the mind, we suggest a novel leptogenesis scenario realized in the false vacuum of the Higgs field. If the Higgs field develops a large vacuum expectation value in the early universe, a lepton number violating process is enhanced, which we use for baryogenesis. To demonstrate the scenario, several models are discussed. For example, we show that the observed baryon asymmetry is successfully generated in the standard model with higher-dimensional operators.

  16. A Labor and Delivery Patient Classification System Based on Direct Nursing Care Time

    DTIC Science & Technology

    1991-08-01

    physician 2409 Internal or external monitoring--uterine contraction/ fetal heart tones 2410 Manual contraction assessment 2411 Pitocin induction...assisting physician 2412 Fetal heart tones, manual 2413 Fetal heart tones, doppler 2414 Fetal scalp sampling, assisting physician 241E Routine delivery room... heart tones, ultrasonic transducer 2437 Monitoring fetal heart tones, ultrasonic transducer and uterine contraction, tocotransducer 69 Appendix B: List

  17. Comparative Evaluation of Vacuum-based Surface Sampling ...

    EPA Pesticide Factsheets

    Journal Article Following a biological contamination incident, collection of surface samples is necessary to determine the extent and level of contamination, and to deem an area safe for reentry upon decontamination. Current sampling strategies targeting Bacillus anthracis spores prescribe vacuum-based methods for rough and/or porous surfaces. In this study, four commonly-used B. anthracis spore sampling devices (vacuum socks, 37 mm 0.8 µm MCE filter cassettes, 37 mm 0.3 µm PTFE filter cassettes, and 3MTM forensic filters) were comparatively evaluated for their ability to recover surface-associated spores. The vacuum sock device was evaluated at two sampling speeds (slow and fast), resulting in five total methods evaluated. Aerosolized spores (~105 cm-2) of a surrogate Bacillus species (Bacillus atrophaeus) were allowed to settle onto three material types (concrete, carpet, and upholstery). Ten replicate samples were collected using each vacuum method, from each of the three material types. In addition, stainless steel (i.e., nonporous) surfaces inoculated simultaneously were sampled with pre-moistened wipes. Recoveries from wipes of steel surfaces were utilized to verify the inoculum, and to normalize vacuum-based recoveries across trials. Recovery (CFU cm-2) and relative recovery (vacuum recovery/wipe recovery) were determined for each method and material type. Relative recoveries were compared by one-way and three-way ANOVA. Data analysis by one-

  18. Mercury Conditions for the MESSENGER Mission Simulated in High- Solar-Radiation Vacuum Tests

    NASA Technical Reports Server (NTRS)

    Wong, Wayne A.

    2003-01-01

    identifying design solutions and validating thermal performance models under a very aggressive development schedule. The test data have assisted Johns Hopkins engineers in selecting a flight solar array vendor and a thermal shield design. MESSENGER is one in a series of missions in NASA's Discovery Program. Infrared thermography provides data on the thermal gradients in the MESSENGER components during high solar insolation vacuum testing.

  19. Porous Hydroxyapatite Bioceramic Scaffolds for Drug Delivery and Bone Regeneration

    NASA Astrophysics Data System (ADS)

    Loca, Dagnija; Locs, Janis; Salma, Kristine; Gulbis, Juris; Salma, Ilze; Berzina-Cimdina, Liga

    2011-10-01

    The conventional methods of supplying a patient with pharmacologic active substances suffer from being very poorly selective, so that damage can occurs to the healthy tissues and organs, different from the intended target. In addition, high drug doses can be required to achieve the desired effect. An alternative approach is based on the use of implantable delivery tools, able to release the active substance in a controlled way. In the current research local drug delivery devices containing 8mg of gentamicin sulphate were prepared using custom developed vacuum impregnation technique. In vitro dissolution tests showed that gentamicin release was sustained for 12h. In order to decrease gentamicin release rate, biopolymer coatings were applied and coating structure investigated. The results showed that gentamicin release can be sustained for more than 70h for poly(epsilon-caprolactone) coated calcium phosphate scaffolds. From poly lactic acid and polyvinyl alcohol coated scaffolds gentamicin was released within 20h and 50h, respectively.

  20. Vacuum energy from noncommutative models

    NASA Astrophysics Data System (ADS)

    Mignemi, S.; Samsarov, A.

    2018-04-01

    The vacuum energy is computed for a scalar field in a noncommutative background in several models of noncommutative geometry. One may expect that the noncommutativity introduces a natural cutoff on the ultraviolet divergences of field theory. Our calculations show however that this depends on the particular model considered: in some cases the divergences are suppressed and the vacuum energy is only logarithmically divergent, in other cases they are stronger than in the commutative theory.

  1. Sealed vacuum canister and method for pick-up and containment of material

    DOEpatents

    Stoutenburgh, Roger R.

    1996-01-01

    A vacuum canister including a housing with a sealed vacuum chamber having a predetermined vacuum pressure therein and a valve having a first port for fluid communication with the vacuum chamber and a second port for receiving at least one of a fluid and a particulate material. The valve is operable between a first position to seal the vacuum chamber and retain the predetermined vacuum within the vacuum chamber, and a second position to access the vacuum chamber to permit vacuum fluid flow through the valve from the second port into the vacuum chamber. In operation of the vacuum canister to pick up material with the valve in the second position, when the second port is located adjacent at least one of a fluid and a particulate material, is effective to displace through the valve at least one of a fluid and a particulate material into the housing. The vacuum canister is desirably suitable for picking up and containing hazardous material such as radioactive material, in which the vacuum canister includes a protective layer of lead having a predetermined thickness that is effective to shield radiation emitted from the radioactive material contained within the housing. Advantageously, the vacuum canister includes a vacuum means for establishing a predetermined vacuum pressure within the vacuum chamber.

  2. An ultra-high vacuum chamber for scattering experiments featuring in-vacuum continuous in-plane variation of the angle between entrance and exit vacuum ports

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Englund, Carl-Johan; Agåker, Marcus, E-mail: marcus.agaker@physics.uu.se; Fredriksson, Pierre

    2015-09-15

    A concept that enables in-vacuum continuous variation of the angle between two ports in one plane has been developed and implemented. The vacuum chamber allows for measuring scattering cross sections as a function of scattering angle and is intended for resonant inelastic X-ray scattering experiments. The angle between the ports can be varied in the range of 30°-150°, while the pressure change is less than 2 × 10{sup −10} mbars.

  3. Cryo-vacuum testing of the JWST Integrated Science Instrument Module (SPIE)

    NASA Technical Reports Server (NTRS)

    Kimble, Randy A.; Vila, M. Begona; Van Campen, Julie; Birkmann, Stephan M.; Comber, Brian J.; Fatig, Curtis C.; Glasse, Alistair C. H.; Glazer, Stuart D.; Kelly, Douglas M.; Mann, Steven D.; hide

    2016-01-01

    In late 2015/early 2016, a major cryo-vacuum test was carried out for the Integrated Science Instrument Module (ISIM) of the James Webb Space Telescope (JWST). This test comprised the final cryo-certification and calibration test of the ISIM, after its ambient environmental test program (vibration, acoustics, EMI/EMC), and before its delivery for integration with the rest of the JWST observatory. Over the 108-day period of the round-the-clock test program, the full complement of ISIM flight instruments, structure, harness radiator, and electronics were put through a comprehensive program of thermal, optical, electrical, and operational tests. The test verified the health and excellent performance of the instruments and ISIM systems, proving the ISIM element's readiness for integration with the telescope. We report here on the context, goals, setup, execution, and key results for this critical JWST milestone.

  4. Treatment of resistant port wine stains (PWS) with pulsed dye laser and non-contact vacuum: a pilot study.

    PubMed

    Kautz, Gerd; Kautz, Ingrid; Segal, Jenny; Zehren, Sabrina

    2010-07-01

    The blanching of resistant port wine stains (PWS) with a pulsed dye laser (PDL) requires a large number of treatments, resulting in substantial discomfort to patients, many of them children. Pneumatic skin flattening (PSF - Serenity Pro) is a new technology that generates a vacuum over the skin and reduces pain in laser-based treatments of the skin, while creating contact between the skin and an upper window. The same technology can be utilized to increase skin blood fraction while operated in a non-contact mode. The objective of this study was to test the enhancement in the efficacy of PWS treatment with PDL and Serenity Pro while vacuum is being utilized in the non-contact, blood-enrichment mode. Fifteen patients with resistant PWS underwent 1-4 treatments (interval of 5-20 weeks) under general anesthesia with a 595-nm PDL at 10-14 J/cm(2), 1.5-3 ms pulse duration, and 7-mm spot size. Lesion blanching with DCD chilling and with vacuum were photographed and compared. Better blanching of various degrees was observed on resistant PWS with the blood-enrichment technique in seven out of 11 patients who returned for follow-up. There were no cases of decrease in efficacy. Blood enrichment with the Serenity Pro non-contact vacuum technology has the potential of enhancing the capability of treating resistant port wine stains in over 50% of cases. Further studies will better quantify the number of treatments necessary for better lesion clearance. The vacuum-assisted technique may be of particular importance in view of the fact that achieving complete lesion clearance remains a challenge in PWS treatments.

  5. Overview of Fabrication Techniques and Lessons Learned with Accelerator Vacuum Windows

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ader, C. R.; McGee, M. W.; Nobrega, L. E.

    Vacuum thin windows have been used in Fermilab's accelerators for decades and typically have been overlooked in terms of their criticality and fragility. Vacuum windows allow beam to pass through while creating a boundary between vacuum and air or high vacuum and low vacuum areas. The design of vacuum windows, including Titanium and Beryllium windows, will be discussed as well as fabrication, testing, and operational concerns. Failure of windows will be reviewed as well as safety approaches to mitigating failures and extending the lifetimes of vacuum windows. Various methods of calculating the strengths of vacuum windows will be explored, includingmore » FEA.« less

  6. Safety shield for vacuum/pressure-chamber windows

    NASA Technical Reports Server (NTRS)

    Shimansky, R. A.; Spencer, R.

    1980-01-01

    Optically-clear shatter-resistant safety shield protects workers from implosion and explosion of vacuum and pressure windows. Plastic shield is inexpensive and may be added to vacuum chambers, pressure chambers, and gas-filling systems.

  7. Efficacy and cost-effectiveness of stereotactic vacuum-assisted core biopsy of nonpalpable breast lesions: analysis of 602 biopsies performed over 5 years.

    PubMed

    Luparia, A; Durando, M; Campanino, P; Regini, E; Lucarelli, D; Talenti, A; Mattone, G; Mariscotti, G; Sapino, A; Gandini, G

    2011-04-01

    The authors sought to evaluate the diagnostic accuracy and cost-effectiveness of vacuum-assisted core biopsy (VACB) in comparison with diagnostic surgical excision for characterisation of nonpalpable breast lesions classified as Breast Imaging Reporting and Data System (BI-RADS) categories R3 and R4. From January 2004 to December 2008, we conducted 602 stereotactic, 11-gauge, VACB procedures on 243 nonpalpable breast lesions categorised as BI-RADS R3, 346 categorised as BI-RADS R4 and 13 categorised as BI-RADS R5. We calculated the diagnostic accuracy and cost savings of VACB by subtracting the cost of the stereotactic biopsy from that of the diagnostic surgical procedure. A total of 56% of the lesions were benign and required no further assessment. Lesions of uncertain malignant potential (B3) (23.6%) were debated at multidisciplinary meetings, and diagnostic surgical biopsy was recommended for 83.1% of them. All malignant lesions (B4 and B5) underwent surgical excision. VACB had a sensitivity of 94.9%, specificity of 98.3% and diagnostic accuracy of 97.7%. The cost savings per VACB procedure were 464.00 euro; by obviating 335 surgical biopsies, the overall cost savings was 155,440.00 euro over 5 years. VACB proved to have high diagnostic accuracy for characterising abnormalities at low to intermediate risk of malignancy and obviated surgical excision in about half of the cases, allowing for considerable cost savings.

  8. Vacuum-Assisted Low-Temperature Synthesis of Reduced Graphene Oxide Thin-Film Electrodes for High-Performance Transparent and Flexible All-Solid-State Supercapacitors.

    PubMed

    Aytug, Tolga; Rager, Matthew S; Higgins, Wesley; Brown, Forrest G; Veith, Gabriel M; Rouleau, Christopher M; Wang, Hui; Hood, Zachary D; Mahurin, Shannon M; Mayes, Richard T; Joshi, Pooran C; Kuruganti, Teja

    2018-04-04

    Simple and easily integrated design of flexible and transparent electrode materials affixed to polymer-based substrates hold great promise to have a revolutionary impact on the functionality and performance of energy storage devices for many future consumer electronics. Among these applications are touch sensors, roll-up displays, photovoltaic cells, health monitors, wireless sensors, and wearable communication devices. Here, we report an environmentally friendly, simple, and versatile approach to produce optically transparent and mechanically flexible all-solid-state supercapacitor devices. These supercapacitors were constructed on tin-doped indium oxide coated polyethylene terephthalate substrates by intercalation of a polymer-based gel electrolyte between two reduced graphene oxide (rGO) thin-film electrodes. The rGO electrodes were fabricated simply by drop-casting of graphene oxide (GO) films, followed by a novel low-temperature (≤250 °C) vacuum-assisted annealing approach for the in situ reduction of GO to rGO. A trade-off between the optical transparency and electrochemical performance is determined by the concentration of the GO in the initial dispersion, whereby the highest capacitance (∼650 μF cm -2 ) occurs at a relatively lower optical transmittance (24%). Notably, the all-solid-state supercapacitors demonstrated excellent mechanical flexibility with a capacity retention rate above 90% under various bending angles and cycles. These attributes underscore the potential of the present approach to provide a path toward the realization of thin-film-based supercapacitors as flexible and transparent energy storage devices for a variety of practical applications.

  9. Vacuum tool manipulator

    DOEpatents

    Zollinger, W.T.

    1993-11-23

    Apparatus for manipulating a vacuum hose in a reactor vessel comprises a housing with two opposing openings, an arm carried by the housing and deployable from a stowed position essentially completely within the housing to an extended position where the arm extends through the two openings in a generally horizontal position. The arm preferably has a two-fingered gripping device for gripping the vacuum hose but may carry a different end effector such as a grinding wheel. The fingers are opened and closed by one air cylinder. A second air cylinder extends the device. A third air cylinder within the housing pivotally pulls the opposing end of the arm into the housing via a pivoting member pivotally connected between the third air cylinder shaft and the arm. 6 figures.

  10. Extreme-UV lithography vacuum chamber zone seal

    DOEpatents

    Haney, Steven J.; Herron, Donald Joe; Klebanoff, Leonard E.; Replogle, William C.

    2001-01-01

    Control of particle contamination on the reticle and carbon contamination of optical surfaces in photolithography systems can be achieved by the establishment of multiple pressure zones in the photolithography systems. The different zones will enclose the reticle, projection optics, wafer, and other components of system. The system includes a vacuum apparatus that includes: a housing defining a vacuum chamber; one or more metrology trays situated within the vacuum chamber each of which is supported by at least one support member, wherein the tray separates the vacuum chamber into a various compartments that are maintained at different pressures; and conductance seal devices for adjoining the perimeter of each tray to an inner surface of the housing wherein the tray is decoupled from vibrations emanating from the inner surface of the housing.

  11. Extreme-UV lithography vacuum chamber zone seal

    DOEpatents

    Haney, Steven J.; Herron, Donald Joe; Klebanoff, Leonard E.; Replogle, William C.

    2003-04-08

    Control of particle contamination on the reticle and carbon contamination of optical surfaces in photolithography systems can be achieved by the establishment of multiple pressure zones in the photolithography systems. The different zones will enclose the reticle, projection optics, wafer, and other components of system. The system includes a vacuum apparatus that includes: a housing defining a vacuum chamber; one or more metrology trays situated within the vacuum chamber each of which is supported by at least one support member, wherein the tray separates the vacuum chamber into a various compartments that are maintained at different pressures; and conductance seal devices for adjoining the perimeter of each tray to an inner surface of the housing wherein the tray is decoupled from vibrations emanating from the inner surface of the housing.

  12. Extreme-UV lithography vacuum chamber zone seal

    DOEpatents

    Haney, Steven J.; Herron, Donald Joe; Klebanoff, Leonard E.; Replogle, William C.

    2003-04-15

    Control of particle contamination on the reticle and carbon contamination of optical surfaces in photolithography systems can be achieved by the establishment of multiple pressure zones in the photolithography systems. The different zones will enclose the reticle, projection optics, wafer, and other components of system. The system includes a vacuum apparatus that includes: a housing defining a vacuum chamber; one or more metrology trays situated within the vacuum chamber each of which is supported by at least one support member, wherein the tray separates the vacuum chamber into a various compartments that are maintained at different pressures; and conductance seal devices for adjoining the perimeter of each tray to an inner surface of the housing wherein the tray is decoupled from vibrations emanating from the inner surface of the housing.

  13. Vacuum deposition and curing of liquid monomers apparatus

    DOEpatents

    Affinito, J.D.

    1996-08-20

    The present invention is the formation of solid polymer layers under vacuum. More specifically, the present invention is the use of ``standard`` polymer layer-making equipment that is generally used in an atmospheric environment in a vacuum, and degassing the monomer material prior to injection into the vacuum. Additional layers of polymer or metal or oxide may be vacuum deposited onto solid polymer layers. Formation of polymer layers under a vacuum improves material and surface characteristics, and subsequent quality of bonding to additional layers. Further advantages include use of less to no photoinitiator for curing, faster curing, fewer impurities in the polymer electrolyte, as well as improvement in material properties including no trapped gas resulting in greater density, and reduced monomer wetting angle that facilitates spreading of the monomer and provides a smoother finished surface. 3 figs.

  14. Microneedles as the technique of drug delivery enhancement in diverse organs and tissues.

    PubMed

    Rzhevskiy, Alexey S; Singh, Thakur Raghu Raj; Donnelly, Ryan F; Anissimov, Yuri G

    2018-01-28

    Microneedles is the technique of drug delivery enhancement, which was primarily designed for facilitating percutaneous drug delivery. Started from the development of simple solid microneedles, providing microporation of stratum corneum and therefore enhancement of topical drug delivery, for two decades the technique has progressed in various modifications such as hollow, coated, dissolving and hydrogel forming microneedles. In their turn, the modifications have resulted in new mechanisms of drug delivery enhancement and followed by the expansion of applicability range in terms of targeted tissues and organs. Thus, in addition to percutaneous drug delivery, microneedles have been considered as an efficient technique facilitating ocular, oral mucosal, gastrointestinal, ungual and vaginal drug administration. It is anticipated that the technique of microneedle-assisted drug delivery will soon become relevant for majority of organs and tissues. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. All pure flat atypical atypia lesions of the breast diagnosed using percutaneous vacuum-assisted breast biopsy do not need surgical excision.

    PubMed

    Ouldamer, Lobna; Poisson, Elodie; Arbion, Flavie; Bonneau, Carole; Vildé, Anne; Body, Gilles; Michenet, Patrick

    2018-04-14

    The purposes of this study were to evaluate the outcome of women with pure flat atypical atypia (FEA) diagnosed at vacuum-assisted breast biopsy (VABB) targeting microcalcifications and to determine whether clinical, radiological and pathologic parameters are able to predict which lesions will be upgraded to malignancy. 2414 cases of consecutive VABB for microcalcifications using VA 8-, 10- or 11-Gauge stereotactically guided core biopsy performed between January 2005 and December 2011 from two french breast cancer centers were evaluated. Data of women with VABB-diagnosed pure FEA who underwent either excisional surgery or mammographic follow-up were analyzed. Cases with mass lesions or ipsilateral cancers were excluded. Two pathologists (FA,PM) reviewed the results of procedures performed. Clinical, radiological, as well as histological criteria have been studied in order to determine the correlation between these factors and carcinoma underestimation. This study included 70 cases of pure FEA. Twenty women underwent surgical excision and 50 had clinical and mammographic surveillance only. In three women FEA was upgraded to breast cancer on excision. Clinical and mammographic follow-up for a mean of 56 months ± 27 in the group without excision showed two cancers in the same breast (Intermediate grade DCIS, and invasive ductal carcinoma 84 and 48 months respectively after VABB). Three factors were significantly predictive of underestimation or occurence of cancer for pure FEA when the radiologic lesions are calcifications: age≥ 57 years, radiologic size >10 mm and number of FEA foci ≥4. Copyright © 2018. Published by Elsevier Ltd.

  16. Employee assistance programs: an overview and suggested roles for psychiatrists.

    PubMed

    Brill, P; Herzberg, J; Speller, J L

    1985-07-01

    Although employee assistance programs are rapidly becoming the predominant vehicle for the delivery of mental health services in occupational settings, few programs employ a psychiatrist on either a part-time or a full-time basis. After providing an overview of the need for, cost-effectiveness of, and current status of employee assistance programs, the authors draw on their own experiences with employee assistance programs to present four broad categories of roles the psychiatrist can assume in such programs: clinician, supervisor and educator, administrator, and organizational consultant. Problems encountered in these roles are also discussed.

  17. Microbial analysis of meatballs cooled with vacuum and conventional cooling.

    PubMed

    Ozturk, Hande Mutlu; Ozturk, Harun Kemal; Koçar, Gunnur

    2017-08-01

    Vacuum cooling is a rapid evaporative cooling technique and can be used for pre-cooling of leafy vegetables, mushroom, bakery, fishery, sauces, cooked food, meat and particulate foods. The aim of this study was to apply the vacuum cooling and the conventional cooling techniques for the cooling of the meatball and to show the vacuum pressure effect on the cooling time, the temperature decrease and microbial growth rate. The results of the vacuum cooling and the conventional cooling (cooling in the refrigerator) were compared with each other for different temperatures. The study shows that the conventional cooling was much slower than the vacuum cooling. Moreover, the microbial growth rate of the vacuum cooling was extremely low compared with the conventional cooling. Thus, the lowest microbial growth occurred at 0.7 kPa and the highest microbial growth was observed at 1.5 kPa for the vacuum cooling. The mass loss ratio for the conventional cooling and vacuum cooling was about 5 and 9% respectively.

  18. Recycling of waste lead storage battery by vacuum methods.

    PubMed

    Lin, Deqiang; Qiu, Keqiang

    2011-07-01

    Waste lead storage battery is the most important recyclable lead material not only in various European and other OECD countries but also in China. Pollution control of lead has become the focus of people's attention in the world. A vacuum process for recycling waste lead storage battery was developed in this work. The experimental results showed that all the valuable materials in waste lead storage battery could be satisfactorily recycled by vacuum technologies. The vacuum melting of lead grids and the vacuum reduction of lead pastes produce the lead bullion with the direct recovery ratio of 96.29% and 98.98%, respectively. The vacuum pyrolysis of plastics can produce pyrolysis oil with yield of more than 93 wt.%. These vacuum recycling technologies offer improvements in metallurgical and environmental performance. Copyright © 2011 Elsevier Ltd. All rights reserved.

  19. Sealed vacuum canister and method for pick-up and containment of material

    DOEpatents

    Stoutenburgh, R.R.

    1996-02-13

    A vacuum canister is described including a housing with a sealed vacuum chamber having a predetermined vacuum pressure therein and a valve having a first port for fluid communication with the vacuum chamber and a second port for receiving at least one of a fluid and a particulate material. The valve is operable between a first position to seal the vacuum chamber and retain the predetermined vacuum within the vacuum chamber, and a second position to access the vacuum chamber to permit vacuum fluid flow through the valve from the second port into the vacuum chamber. The vacuum canister, in the operation to pick up material with the valve in the second position, when the second port is located adjacent at least one of a fluid and a particulate material, is effective to displace through the valve at least one of a fluid and a particulate material into the housing. The vacuum canister is desirably suitable for picking up and containing hazardous material such as radioactive material, in which the vacuum canister includes a protective layer of lead having a predetermined thickness that is effective to shield radiation emitted from the radioactive material contained within the housing. Advantageously, the vacuum canister includes a vacuum means for establishing a predetermined vacuum pressure within the vacuum chamber. 6 figs.

  20. Vacuum transfer system increases sugar maple sap yield

    Treesearch

    Russell S. Walters

    1978-01-01

    Yields of sugar maple sap collected from three plastic pipeline systems by gravity, vacuum pump, and a vacuum pump with a transfer tank were compared during 2 years in northern Vermont. The transfer system yielded 27 percent more sap one year and 17 percent more the next year. Higher vacuum levels at the tapholes were observed in the transfer system.

  1. Vacuum plasma coatings for turbine blades

    NASA Technical Reports Server (NTRS)

    Holmes, R. R.

    1985-01-01

    Turbine blades, vacuum plasma spray coated with NiCrAlY, CoCrAlY or NiCrAlY/Cr2O3, were evaluated and rated superior to standard space shuttle main engine (SSME) coated blades. Ratings were based primarily on 25 thermal cycles in the MSFC Burner Rig Tester, cycling between 1700 F (gaseous H2) and -423 F (liquid H2). These tests showed no spalling on blades with improved vacuum plasma coatings, while standard blades spalled. Thermal barrier coatings of ZrO2, while superior to standard coatings, lacked the overall performance desired. Fatigue and tensile specimens, machined from MAR-M-246(Hf) test bars identical to the blades were vacuum plasma spray coated, diffusion bond treated, and tested to qualify the vacuum plasma spray process for flight hardware testing and application. While NiCrAlY/Cr2O3 offers significant improvement over standard coatings in durability and thermal protection, studies continue with an objective to develop coatings offering even greater improvements.

  2. Self contained, independent, in-vacuum spinner motor

    DOEpatents

    Ayers, Marion J.

    2002-01-01

    An independent, self contained apparatus for operation within a vacuum chamber. A sealed enclosure is located in the chamber. The enclosure contains its own atmosphere independent of the vacuum in the chamber. A motor, power unit, and controls are located entirely within the enclosure. They do not have a direct structural connection outside of the enclosure in any way that would effect the atmosphere within the enclosure. The motor, power unit, and controls drive a spinner plate located outside the enclosure but within the vacuum chamber.

  3. Microscale Digital Vacuum Electronic Gates

    NASA Technical Reports Server (NTRS)

    Manohara, Harish (Inventor); Mojarradi, Mohammed M. (Inventor)

    2014-01-01

    Systems and methods in accordance with embodiments of the invention implement microscale digital vacuum electronic gates. In one embodiment, a microscale digital vacuum electronic gate includes: a microscale field emitter that can emit electrons and that is a microscale cathode; and a microscale anode; where the microscale field emitter and the microscale anode are disposed within at least a partial vacuum; where the microscale field emitter and the microscale anode are separated by a gap; and where the potential difference between the microscale field emitter and the microscale anode is controllable such that the flow of electrons between the microscale field emitter and the microscale anode is thereby controllable; where when the microscale anode receives a flow of electrons, a first logic state is defined; and where when the microscale anode does not receive a flow of electrons, a second logic state is defined.

  4. Instrument for measurement of vacuum in sealed thin wall packets

    DOEpatents

    Kollie, T.G.; Thacker, L.H.; Fine, H.A.

    1995-04-18

    An instrument is disclosed for the measurement of vacuum within sealed packets, the packets having a wall that it can be deformed by the application of an external dynamic vacuum to an area thereof. The instrument has a detector head for placement against the deformable wall of the packet to apply the vacuum in a controlled manner to accomplish a limited deformation or lift of the wall with this deformation or lift monitored by the application of light as via a bifurcated light pipe. Retro-reflected light through the light pipe is monitored with a photo detector. A change (e.g., a decrease) of retro-reflected light signals the wall movement such that the value of the dynamic vacuum applied through the head be to achieve this initiation of movement is equal to the vacuum within the packet. In a preferred embodiment a vacuum plate is placed beneath the packet to ensure that no deformation occurs on the reverse surface of the packet. A vacuum can be applied to a recess in this vacuum plate, the value of which can be used to calibrate the vacuum transducer in the detector head. 4 figs.

  5. Antioxidant Nanoplatforms for Dermal Delivery: Melatonin.

    PubMed

    Milan, Aroha Sanchez; Campmany, Ana Cristina Calpena; Naveros, Beatriz Clares

    2017-01-01

    Melatonin is emerging as a promising therapeutic agent, mainly due to its role as antioxidant. Substantial evidences show that melatonin is potentially effective in a variety of diseases as cancer, inflammation and neurodegenerative diseases. The excellent antioxidant capacity with pharmacokinetics characteristics and the emerging search for new pharmaceutical nanotechnology based systems, make it particularly attractive to elaborate nanoplatforms based on melatonin for biomedical or cosmetic dermal applications. Different nanosystems for dermal delivery have been investigated. This review focuses on nanocarrier production strategies, dermal melatonin application and delivery advances in vivo and in vitro. Equally, future perspectives of this assisted melatonin delivery have also been discussed. In the current review, we have revised relevant articles of the available literature using the major scientific databases. One hundred and thirteen papers were included in the review, the majority of which represent latest researches in nanosized platforms for the dermal delivery of melatonin including liposomes, ethosomes, niosomes, polymeric nanoparticles, solid lipid nanoparticles and cyclodextrins. Furthermore, relevant papers reporting in vitro and in vivo application studies of these nano-based melatonin platforms were also discussed. The use of nanoplatforms for the dermal melatonin delivery as antioxidant agent could improve the efficacy of conventional melatonin administration due to the preservation of the drug from premature oxidation and the enhancement of drug permeation through the skin providing greater exposure times. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  6. Effect of Vacuum on Venous Drainage: an Experimental Evaluation on Pediatric Venous Cannulas and Tubing Systems.

    PubMed

    Vida, V L; Bhattarai, A; Speggiorin, S; Zanella, F; Stellin, G

    2014-01-01

    To observe how vacuum assisted venous drainage (VAVD) may influence the flow in a cardiopulmonary bypass circuit with different size of venous lines and cannulas. The experimental circuit was assembled to represent the cardiopulmonary bypass circuit routinely used during cardiac surgery. Wall suction was applied directly, modulated and measured into the venous reservoir. The blood flow was measured with a flow-meter positioned on the venous line. The circuit prime volume was replaced with group O date expired re-suspended red cells and Plasmalyte 148 to a hematocrit of 28% to 30%. In an open circuit with gravity siphon venous drain, angled cannulae drain more than straight ones regardless the amount of suction applied to the venous line (16 Fr straight cannula (S) drains 90 ml/min less than a 16 Fr angled (A) with a siphon gravity). The same flow can be obtained with lower cannula size and higher suction (i.e. 12 A with and -30 mmHg). Tables have been created to list how the flow varies according to the size of the cannulas, the size of the venous tubes, and the amount of suction applied to the system. Vacuum assisted venous drainage allows the use of smaller cannulae and venous lines to maintain a good venous return, which is very useful during minimally invasive approaches. The present study should be considered as a preliminary attempt to create a scientific-based starting point for a uniform the use of VAVD.

  7. A comparison study on a sulfonated graphene-polyaniline nanocomposite coated fiber for analysis of nicotine in solid samples through the traditional and vacuum-assisted HS-SPME.

    PubMed

    Ghiasvand, Alireza; Koonani, Samira; Yazdankhah, Fatemeh; Farhadi, Saeid

    2018-02-05

    A simple, rapid, and reliable headspace solid-phase microextraction (HS-SPME) procedure, reinforced by applying vacuum in the extraction vial, was developed. It was applied for the extraction of nicotine in solid samples prior to determination by gas chromatography-flame ionization detection (GC-FID). First, the surface of a narrow stainless steel wire was made porous and adhesive by platinization to obtain a durable, higher surface area, and resistant fiber. Then, a thin film of sulfonated graphene/polyaniline (Sulf-G/PANI) nanocomposite was synthesized and simultaneously coated on the platinized fiber using the electrophoretic deposition (EPD) method. It was demonstrated that the extraction efficiency remarkably increased by applying the reduced-pressure condition in the extraction vial. To evaluate the conventional HS-SPME and vacuum-assisted HS-SPME (VA-HS-SPME) platforms, all experimental parameters affecting the extraction efficiency including desorption time and temperature, extraction time and temperature and moisture content of sample matrix were optimized. The highest extraction efficiency was obtained at 60°C, 10min (extraction temperature and time) and 280°C, 2min (desorption condition), for VA-HS-SPME strategy, while for conventional HS-SPME the extraction and desorption conditions found to be 100°C, 30min and 280°C, 2min, respectively. The Sulf-G/PANI coated fiber showed high thermal stability, good chemical/mechanical resistance, and long lifetime. For analysis of nicotine in solid samples using VA-HS-SPME-GC-FID, linear dynamic range (LDR) was 0.01-30μgg -1 (R 2 =0.996), the relative standard deviation (RSD%, n=6), for analyses of 1μgg -1 nicotine was calculated 3.4% and limit of detection (LOD) found to be 0.002μgg -1 . The VA-HS-SPME-GC-FID strategy was successfully carried out for quantitation of nicotine in hair and tobacco real samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Dyonic Flux Tube Structure of Nonperturbative QCD Vacuum

    NASA Astrophysics Data System (ADS)

    Chandola, H. C.; Pandey, H. C.

    We study the flux tube structure of the nonperturbative QCD vacuum in terms of its dyonic excitations by using an infrared effective Lagrangian and show that the dyonic condensation of QCD vacuum has a close connection with the process of color confinement. Using the fiber bundle formulation of QCD, the magnetic symmetry condition is presented in a gauge covariant form and the gauge potential has been constructed in terms of the magnetic vectors on global sections. The dynamical breaking of the magnetic symmetry has been shown to lead the dyonic condensation of QCD vacuum in the infrared energy sector. Deriving the asymptotic solutions of the field equations in the dynamically broken phase, the dyonic flux tube structure of QCD vacuum is explored which has been shown to lead the confinement parameters in terms of the vector and scalar mass modes of the condensed vacuum. Evaluating the charge quantum numbers and energy associated with the dyonic flux tube solutions, the effect of electric excitation of monopole is analyzed using the Regge slope parameter (as an input parameter) and an enhancement in the dyonic pair correlations and the confining properties of QCD vacuum in its dyonically condensed mode has been demonstrated.

  9. The Function of Emulsions on the Biogenic Amine Formation and their Indices of Sea Bass Fillets (Dicentrarchus Labrax) Stored in Vacuum Packaging.

    PubMed

    Ozogul, Yesim; Durmus, Mustafa; Kuley Boga, Esmeray; Uçar, Yılmaz; Ozogul, Fatih

    2018-02-01

    The impacts of emulsions based on commercial oils on the biogenic amine formation and their indices of vacuumed packed sea bass fillets were investigated. The results showed that among biogenic amines, cadaverine, putrescine, spermidine, spermine, serotonin, dopamine, and agmatine were predominant amines in sea bass fillets stored under vacuum packaging. Significant differences (P < 0.05) in biogenic amines concentrations of vacuumed packed sea bass treated with emulsions were observed. All groups contained histamine lower than 5.0 mg/100 g, regarded as the allowable limit by the U.S. Food and Drug Administration. Polyamine levels were not affected by application of emulsion. Quality index (QI) showed an increase and after 14 d of storage it decreased in all groups. The control generally seemed to higher QI value than those of treatment groups except at 14 and 18 days while soybean and corn gave lower QI among treatment groups. Only biogenic amine index correlated with sensory acceptability of vacuumed packed sea bass, indicating that this index can be used for determination of the degree of spoilage of vacuumed packed sea bass. Emulsions extended the shelf-life (approximately 2 to 4 d) of vacuumed packed sea bass fillets by inhibiting microbial growth compared to the control. Emulsions have become popular since they are regarded as ideal carrier for the delivery of lipophilic substances due to the ease of preparation, small particle size, their enhanced bioavailability, and long term kinetic stability. They have been proven to be self-preserving antimicrobials due to bound water in their structure and thus no available water to microorganisms. Antimicrobial emulsions have potential applications in many fields because they are inexpensive, stable, and nontoxic agents. © 2018 Institute of Food Technologists®.

  10. Flow Visualization Proposed for Vacuum Cleaner Nozzle Designs

    NASA Technical Reports Server (NTRS)

    2005-01-01

    In 1995, the NASA Lewis Research Center and the Kirby Company (a major vacuum cleaner company) began negotiations for a Space Act Agreement to conduct research, technology development, and testing involving the flow behavior of airborne particulate flow behavior. Through these research efforts, we hope to identify ways to improve suction, flow rate, and surface agitation characteristics of nozzles used in vacuum cleaner nozzles. We plan to apply an advanced visualization technology, known as Stereoscopic Imaging Velocimetry (SIV), to a Kirby G-4 vacuum cleaner. Resultant data will be analyzed with a high-speed digital motion analysis system. We also plan to evaluate alternative vacuum cleaner nozzle designs. The overall goal of this project is to quantify both velocity fields and particle trajectories throughout the vacuum cleaner nozzle to optimize its "cleanability"--its ability to disturb and remove embedded dirt and other particulates from carpeting or hard surfaces. Reference

  11. Innovative Free-range Resonant Electrical Energy Delivery system (FREE-D System) for a ventricular assist device using wireless power.

    PubMed

    Waters, Benjamin H; Smith, Joshua R; Bonde, Pramod

    2014-01-01

    Technological innovation of a smaller, single moving part has an advantage over earlier large pulsatile ventricular assist devices (VADs) prone to mechanical failure. Drivelines limit the potential for extended patient survival durations with newer pumps and act as source for infection, increased morbidity, rehospitalizations, and reduced quality of life. The Free-range Resonant Electrical Energy Delivery (FREE-D) wireless power system uses magnetically coupled resonators to efficiently transfer power. We demonstrate the efficiency over distance of this system. The experimental setup consists of an radiofrequency amplifier and control board which drives the transmit resonator coil, and a receiver unit consisting of a resonant coil attached to a radiofrequency rectifier and power management module. The power management module supplies power to the axial pump, which was set at 9,600 rpm. To achieve a seamless wireless delivery in any room size, we introduced a third relay coil. This relay coil can be installed throughout a room, whereas a single relay coil could be built into a jacket worn by the patient, which would always be within range of the receive coil implanted in the patient's body. The power was delivered over a meter distance without interruptions or fluctuations with coil, rectifier, and regulator efficiency more than 80% and overall system efficiency of 61%. The axial pump worked well throughout the 8 hours of continuous operation. Having same setup on the opposite side can double the distance. A tether-free operation of a VAD can be achieved by FREE-D system in room-size distances. It has the potential to make the VAD therapy more acceptable from the patient perspective.

  12. Red rubber bulb, cheap and effective vacuum drainage.

    PubMed

    Vatanasapt, V; Areemit, S; Jeeravipoolvarn, P; Kuyyakanond, T; Kuptarnond, C

    1989-04-01

    Red rubber bulbs have been used for vacuum drainage in head, neck, breast and several other operations by the authors since 1975 quite effectively without any major problems. The vacuum pressure of the red rubber bulbs was found to be higher than the expensive commercially available vacuum wound drainage device. The question of remaining old blood and infective microorganisms inside the reservoir for the reused ones were tested by the manual cleaning process and the standard sterile technique using steam under increased pressure (autoclave). The result is quite satisfactory. We encourage the use of this cheap and effective (made in Thailand) vacuum wound drainage in Thai hospitals and Thai medical schools.

  13. Study of Vacuum Energy Physics for Breakthrough Propulsion

    NASA Technical Reports Server (NTRS)

    Millis, Marc G. (Technical Monitor); Maclay, G. Jordan; Hammer, Jay; Clark, Rod; George, Michael; Kim, Yeong; Kir, Asit

    2004-01-01

    This report summarizes the accomplishments during a three year research project to investigate the use of surfaces, particularly in microelectromechanical systems (MEMS), to exploit quantum vacuum forces. During this project, we developed AFM instrumentation to repeatably measure Casimir forces in the nanoNewton range at 10 6 torr, designed an experiment to measure attractive and repulsive quantum vacuum forces, developed a QED based theory of Casimir forces that includes non-ideal material properties for rectangular cavities and for multilayer slabs, developed theoretical models for a variety of microdevices utilizing vacuum forces, applied vacuum physics to a gedanken spacecraft, and investigated a new material with a negative index of refraction.

  14. Repeat cesarean delivery: what indications are recorded in the medical chart?

    PubMed

    Lydon-Rochelle, Mona T; Gardella, Carolyn; Cárdenas, Vicky; Easterling, Thomas R

    2006-03-01

    National surveillance estimates reported a troubling 63 percent decline in the rate of vaginal birth after cesarean delivery (VBAC) from 1996 (28.3%) to 2003 (10.6%), with subsequent rising rates of repeat cesarean delivery. The study objective was to examine patterns of documented indications for repeat cesarean delivery in women with and without labor. We conducted a population-based validation study of 19 nonfederal short-stay hospitals in Washington state. Of the 4,541 women who had live births in 2000, 11 percent (n = 493) had repeat cesarean without labor and 3 percent (n = 138) had repeat cesarean with labor. Incidence of medical conditions and pregnancy complications, patterns of documented indications for repeat cesarean delivery, and perioperative complications in relation to repeat cesarean delivery with and without labor were calculated. Of the 493 women who underwent a repeat cesarean delivery without labor, "elective"(36%) and "maternal request"(18%) were the most common indications. Indications for maternal medical conditions (3.0%) were uncommon. Among the 138 women with repeat cesarean delivery with labor, 60.1 percent had failure to progress, 24.6 percent a non-reassuring fetal heart rate, 8.0 percent cephalopelvic disproportion, and 7.2 percent maternal request during labor. Fetal indications were less common (5.8%). Breech, failed vacuum, abruptio placentae, maternal complications, and failed forceps were all indicated less than 5.0 percent. Women's perioperative complications did not vary significantly between women without and with labor. Regardless of a woman's labor status, nearly 10 percent of women with repeat cesarean delivery had no documented indication as to why a cesarean delivery was performed. "Elective" and "maternal request" were common indications among women undergoing repeat cesarean delivery without labor, and nearly 10 percent of women had undocumented indications for repeat cesarean delivery in their medical record

  15. Vacuum assisted closure for the treatment of sternal wounds: the bridge between débridement and definitive closure.

    PubMed

    Song, David H; Wu, Liza C; Lohman, Robert F; Gottlieb, Lawrence J; Franczyk, Mieczyslawa

    2003-01-01

    A method to refine the treatment of sternal wounds using Vacuum Assisted Closure (V.A.C.) therapy as the bridge between débridement and delayed definitive closure is described. A retrospective review of 35 consecutive patients with sternal wound complications over a 2-year period (March of 1999 to March of 2001) was performed. The treatment of sternal wounds with traditional twice-a-day dressing changes was compared with the treatment with the wound V.A.C. device. An analysis of the number of days between initial débridement and closure, number of dressing changes, number and types of flaps needed for reconstruction, and complications was performed. Eighteen patients were treated with traditional twice-a-day dressing changes and 17 patients were treated with V.A.C. therapy alone. The two groups were similar regarding age, sex, type of cardiac procedure, and type of sternal wound. The V.A.C. therapy group had a trend toward a shorter interval between débridement and closure, with a mean of 6.2 days, whereas the dressing change group had mean of 8.5 days. The V.A.C. therapy group had a significantly lower number of dressing changes, with a mean of three, whereas the twice-a-day dressing change group had a mean of 17 (p < 0.05). Reconstruction required an average of 1.5 soft-tissue flaps per patient treated with traditional dressing changes versus 0.9 soft-tissue flaps per patient for those treated with V.A.C. therapy (p < 0.05). Before closure, there was one death among patients undergoing dressing changes and three in the V.A.C. therapy group, all of which were unrelated to the management of the sternal wound. Patients with sternal wounds who have benefited from V.A.C. therapy alone have a significant decrease in the number of dressing changes and number of soft-tissue flaps needed for closure. Finally, the V.A.C. therapy group had a trend toward a decreased number of days between débridement and closure.

  16. Computer-Assisted Instruction: Authoring Languages. ERIC Digest.

    ERIC Educational Resources Information Center

    Reeves, Thomas C.

    One of the most perplexing tasks in producing computer-assisted instruction (CAI) is the authoring process. Authoring is generally defined as the process of turning the flowcharts, control algorithms, format sheets, and other documentation of a CAI program's design into computer code that will operationalize the simulation on the delivery system.…

  17. Feed-through connector couples RF power into vacuum chamber

    NASA Technical Reports Server (NTRS)

    Grandy, G. L.

    1967-01-01

    Feed-through device connects RF power to an RF coil in a vacuum chamber. The coil and leads are water cooled and vacuum tight seals are provided at the junctions. The device incorporates silver soldered copper tubes, polytetrafluoroethylene electrical insulators, and O-ring vacuum seals.

  18. Heat transfer in a liquid helium cooled vacuum tube following sudden vacuum loss

    NASA Astrophysics Data System (ADS)

    Dhuley, R. C.; Van Sciver, S. W.

    2015-12-01

    Condensation of nitrogen gas rapidly flowing into a liquid helium (LHe) cooled vacuum tube is studied. This study aims to examine the heat transfer in geometries such as the superconducting RF cavity string of a particle accelerator following a sudden loss of vacuum to atmosphere. In a simplified experiment, the flow is generated by quickly venting a large reservoir of nitrogen gas to a straight long vacuum tube immersed in LHe. Normal LHe (LHe I) and superfluid He II are used in separate experiments. The rate of condensation heat transfer is determined from the temperature of the tube measured at several locations along the gas flow. Instantaneous heat deposition rates in excess of 200 kW/m2 result from condensation of the flowing gas. The gas flow is then arrested in its path to pressurize the tube to atmosphere and estimate the heat transfer rate to LHe. A steady LHe I heat load of ≈25 kW/m2 is obtained in this scenario. Observations from the He II experiment are briefly discussed. An upper bound for the LHe I heat load is derived based on the thermodynamics of phase change of nitrogen.

  19. Instrument for measurement of vacuum in sealed thin wall packets

    DOEpatents

    Kollie, Thomas G.; Thacker, Louis H.; Fine, H. Alan

    1995-01-01

    An instrument for the measurement of vacuum within sealed packets 12, the packets 12 having a wall 14 that it can be deformed by the application of an external dynamic vacuum to an area thereof. The instrument has a detector head 18 for placement against the deformable wall 14 of the packet to apply the vacuum in a controlled manner to accomplish a limited deformation or lift of the wall 14, with this deformation or lift monitored by the application of light as via a bifurcated light pipe 20. Retro-reflected light through the light pipe is monitored with a photo detector 26. A change (e.g., a decrease) of retro-reflected light signals the wall movement such that the value of the dynamic vacuum applied through the head be to achieve this initiation of movement is equal to the vacuum within the packet 12. In a preferred embodiment a vacuum plate 44 is placed beneath the packet 12 to ensure that no deformation occurs on the reverse surface 16 of the packet. A vacuum can be applied to a recess in this vacuum plate, the value of which can be used to calibrate the vacuum transducer in the detector head.

  20. 7 CFR 58.217 - Evaporators and/or vacuum pans.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ....217 Evaporators and/or vacuum pans. Evaporators or vacuum pans or both, with open type condensers shall be equipped with an automatic condenser water level control, barometric leg, or so constructed so... Sanitary Standards for Milk and Milk Products Evaporators and Vacuum Pans. When enclosed type condensers...