Sample records for vacuum interrupter driven

  1. Development of High Interruption Capability Vacuum Circuit Breaker -Technology of Vacuum Arc Control-

    NASA Astrophysics Data System (ADS)

    Niwa, Yoshimitsu; Kaneko, Eiji

    Vacuum circuit breakers (VCB) have been widely used for power distribution systems. Vacuum Interrupters, which are the current interruption unit, have been increased its interruption capability with the development of vacuum arc control technology by magnetic field. There are three major type electrodes: disk shaped electrodes, radial magnetic field electrodes, axial magnetic field (AMF) electrodes. In the disk shaped electrode, the vacuum arc between the electrodes is not controlled. In the AMF electrode, the vacuum arc is diffused and stabilized by an axial magnetic field, which is parallel to the arc current. In the last type of electrodes, the vacuum arc column is rotated by magnetic force generated by the current flowing in the electrodes. The interruption current and the voltage of one break VCB is increased to 100 kA, 144 kV respectively. This paper describes basic configurations and functions of VCB, vacuum arc control technology in vacuum interrupters, recent researches and applications of VCB.

  2. Operating characteristics of superconducting fault current limiter using 24kV vacuum interrupter driven by electromagnetic repulsion switch

    NASA Astrophysics Data System (ADS)

    Endo, M.; Hori, T.; Koyama, K.; Yamaguchi, I.; Arai, K.; Kaiho, K.; Yanabu, S.

    2008-02-01

    Using a high temperature superconductor, we constructed and tested a model Superconducting Fault Current Limiter (SFCL). SFCL which has a vacuum interrupter with electromagnetic repulsion mechanism. We set out to construct high voltage class SFCL. We produced the electromagnetic repulsion switch equipped with a 24kV vacuum interrupter(VI). There are problems that opening speed becomes late. Because the larger vacuum interrupter the heavier weight of its contact. For this reason, the current which flows in a superconductor may be unable to be interrupted within a half cycles of current. In order to solve this problem, it is necessary to change the design of the coil connected in parallel and to strengthen the electromagnetic repulsion force at the time of opening the vacuum interrupter. Then, the design of the coil was changed, and in order to examine whether the problem is solvable, the current limiting test was conducted. We examined current limiting test using 4 series and 2 parallel-connected YBCO thin films. We used 12-centimeter-long YBCO thin film. The parallel resistance (0.1Ω) is connected with each YBCO thin film. As a result, we succeed in interrupting the current of superconductor within a half cycle of it. Furthermore, series and parallel-connected YBCO thin film could limit without failure.

  3. Influence of Gap Distance on Vacuum Arc Characteristics of Cup Type AMF Electrode in Vacuum Interrupters

    NASA Astrophysics Data System (ADS)

    Cheng, Shaoyong; Xiu, Shixin; Wang, Jimei; Shen, Zhengchao

    2006-11-01

    The greenhouse effect of SF6 is a great concern today. The development of high voltage vacuum circuit breakers becomes more important. The vacuum circuit breaker has minimum pollution to the environment. The vacuum interrupter is the key part of a vacuum circuit breaker. The interrupting characteristics in vacuum and arc-controlling technique are the main problems to be solved for a longer gap distance in developing high voltage vacuum interrupters. To understand the vacuum arc characteristics and provide effective technique to control vacuum arc in a long gap distance, the arc mode transition of a cup-type axial magnetic field electrode is observed by a high-speed charge coupled device (CCD) video camera under different gap distances while the arc voltage and arc current are recorded. The controlling ability of the axial magnetic field on vacuum arc obviously decreases when the gap distance is longer than 40 mm. The noise components and mean value of the arc voltage significantly increase. The effective method for controlling the vacuum arc characteristics is provided by long gap distances based on the test results. The test results can be used as a reference to develop high voltage and large capacity vacuum interrupters.

  4. Investigation of Dielectric Breakdown Characteristics for Double-break Vacuum Interrupter and Dielectric Breakdown Probability Distribution in Vacuum Interrupter

    NASA Astrophysics Data System (ADS)

    Shioiri, Tetsu; Asari, Naoki; Sato, Junichi; Sasage, Kosuke; Yokokura, Kunio; Homma, Mitsutaka; Suzuki, Katsumi

    To investigate the reliability of equipment of vacuum insulation, a study was carried out to clarify breakdown probability distributions in vacuum gap. Further, a double-break vacuum circuit breaker was investigated for breakdown probability distribution. The test results show that the breakdown probability distribution of the vacuum gap can be represented by a Weibull distribution using a location parameter, which shows the voltage that permits a zero breakdown probability. The location parameter obtained from Weibull plot depends on electrode area. The shape parameter obtained from Weibull plot of vacuum gap was 10∼14, and is constant irrespective non-uniform field factor. The breakdown probability distribution after no-load switching can be represented by Weibull distribution using a location parameter. The shape parameter after no-load switching was 6∼8.5, and is constant, irrespective of gap length. This indicates that the scatter of breakdown voltage was increased by no-load switching. If the vacuum circuit breaker uses a double break, breakdown probability at low voltage becomes lower than single-break probability. Although potential distribution is a concern in the double-break vacuum cuicuit breaker, its insulation reliability is better than that of the single-break vacuum interrupter even if the bias of the vacuum interrupter's sharing voltage is taken into account.

  5. Interruption Phenomenon in Intermediate-Frequency Vacuum Arc

    NASA Astrophysics Data System (ADS)

    Jiang, Yuan; Wu, Jianwen

    2016-03-01

    In the condition of the 3 mm gap, experiments for 360 Hz intermediate-frequency vacuum arc are carried out in interrupters with the diameters being 41 mm and with the contact materials being CuCr50 and Cu-W-WC alloy respectively. The results indicate that the contacts material is closely related to the breaking capacity of the vacuum interrupters and characteristics of an intermediate-frequency vacuum arc. For contacts with the same diameter, the breaking capacity of CuCr50 is better than that of Cu-W-WC. When the current fails to be interrupted, the arcs overflow the gap and present irregular performances in the first half wave. Consequently a voltage spike appears. More macroscopic metal droplets can be seen in the arc column between CuCr50 contacts because of the lower melting point. It is observed that the droplet emission is much more severe during arc reignition than that in the first half wave. It is much more conspicuous that the high frequency arc voltage noises appear in Cu-W-WC contacts when the vacuum arcs reignite, for higher temperature and stronger electronic emission ability of Cu-W-WC contacts. supported by National Natural Science Foundation of China (No. 51377007), Specialized Research Fund for the Doctoral Program of Higher Education of China (No. 20131102130006), and Fundamental Research Funds for the Central Universities of China

  6. DC Interruption Characteristic on Vacuum Circuit Breaker

    NASA Astrophysics Data System (ADS)

    Odaka, Hiromi; Yamada, Masataka; Sakuma, Ryohei; Ding, Cuie; Kaneko, Eiji; Yanabu, Satoru

    A high speed vacuum circuit breaker (HSVCB) has been investigated. HSVCB makes high frequency current superimposed on a fault current so that the current is forced to be zero and is interrupted. Its interruption performance is considered to be dependent on a rate of change of the current (di/dt). As a fundamental research, we investigated the di/dt-dv/dt characteristics and the insulation recovery characteristic after interrupting the counter-pulse current for various contact materials of AgWC, CuW, and CuCr. The results revealed that the case where gap length is larger is better in a current interruption performance. Moreover, it was found that di/dt is not dependent on the insulation recovery characteristics, but the magnitude of interruption current influences greatly.

  7. Deformation of contact surfaces in a vacuum interrupter after high-current interruptions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Haoran; Wang, Zhenxing, E-mail: zxwang@xjtu.edu.cn; Zhou, Zhipeng

    2016-08-07

    In a high-current interruption, the contact surface in a vacuum interrupter might be severely damaged by constricted vacuum arcs causing a molten area on it. As a result, a protrusion will be initiated by a transient recovery voltage after current zero, enhancing the local electric field and making breakdowns occur easier. The objective of this paper is to simulate the deformation process on the molten area under a high electric field by adopting the finite element method. A time-dependent Electrohydrodynamic model was established, and the liquid-gas interface was tracked by the level-set method. From the results, the liquid metal canmore » be deformed to a Taylor cone if the applied electric field is above a critical value. This value is correlated to the initial geometry of the liquid metal, which increases as the size of the liquid metal decreases. Moreover, the buildup time of a Taylor cone obeys the power law t = k × E{sup −3}, where E is the initial electric field and k is a coefficient related to the material property, indicating a temporal self-similar characteristic. In addition, the influence of temperature has little impact on the deformation but has great impact on electron emission. Finally, the possible reason to initiate a delayed breakdown is associated with the deformation. The breakdown does not occur immediately when the voltage is just applied upon the gap but is postponed to several milliseconds later when the tip is formed on the liquid metal.« less

  8. The Generating Mechanism of Non-Sustained Disruptive Discharges in Vacuum Interrupters

    NASA Astrophysics Data System (ADS)

    Hara, Daisuke; Taki, Masayuki; Tanaka, Hitoshi; Okawa, Mikio; Yanabu, Satoru

    To develop vacuum circuit breaker (VCB) for higher voltage application, it may be important to understand generating mechanism and its influence of non-sustained disruptive discharges (NSDD) to the systems. So, we carried out the tests using equivalent testing circuit and observed the contacts after testing, For the test, by using commercial vacuum circuit interrupters, AC voltages of 50Hz was applied between contacts for 4 seconds after current interruption, and measured generating frequencies of NSDD vs. the voltages and vs. currents. Typical contact material used in the commercial switching equipment, such as AgWC, CuW, CuCr were tested and compared. Then CuCr's of different composition and manufacturing process are investigated. And CuCr-50 (manufactured by melting process) showed the best performance in all tests. We point out that surface condition may affect the generation of NSDD and also conditioning effect is very important.

  9. Interruption of a dry-type transformer in no-load by a vacuum circuit-breaker

    NASA Astrophysics Data System (ADS)

    Vandenheuvel, W. M. C.; Daalder, J. E.; Boone, M. J. M.; Wilmes, L. A. H.

    1983-08-01

    Overvoltages generated during interruption of a dry type delta-star connected transformer in no load by a vacuum breaker were studied. During interruption of inrush current 37% of the phase-to-ground overvoltages were 5 pu, and 6% 7 pu. Comparison of experimental and theoretical results using Boyle's model shows no discrepancy for inrush currents and clean overvoltages from the steady-state interruption. Overvoltages due to repetitive reignitions (not covered by Boyle's model) are higher than the calculated values during steady-state switching.

  10. Effects-Driven Participatory Design: Learning from Sampling Interruptions.

    PubMed

    Brandrup, Morten; Østergaard, Kija Lin; Hertzum, Morten; Karasti, Helena; Simonsen, Jesper

    2017-01-01

    Participatory design (PD) can play an important role in obtaining benefits from healthcare information technologies, but we contend that to fulfil this role PD must incorporate feedback from real use of the technologies. In this paper we describe an effects-driven PD approach that revolves around a sustained focus on pursued effects and uses the experience sampling method (ESM) to collect real-use feedback. To illustrate the use of the method we analyze a case that involves the organizational implementation of electronic whiteboards at a Danish hospital to support the clinicians' intra- and interdepartmental coordination. The hospital aimed to reduce the number of phone calls involved in coordinating work because many phone calls were seen as unnecessary interruptions. To learn about the interruptions we introduced an app for capturing quantitative data and qualitative feedback about the phone calls. The investigation showed that the electronic whiteboards had little potential for reducing the number of phone calls at the operating ward. The combination of quantitative data and qualitative feedback worked both as a basis for aligning assumptions to data and showed ESM as an instrument for triggering in-situ reflection. The participant-driven design and redesign of the way data were captured by means of ESM is a central contribution to the understanding of how to conduct effects-driven PD.

  11. Electric circuit breaker comprising a plurality of vacuum interrupters simultaneously operated by a common operator

    DOEpatents

    Barkan, Philip; Imam, Imdad

    1980-01-01

    This circuit breaker comprises a plurality of a vacuum-type circuit interrupters, each having a movable contact rod. A common operating device for the interrupters comprises a linearly-movable operating member. The interrupters are mounted at one side of the operating member with their movable contact rods extending in a direction generally toward the operating member. Means is provided for mechanically coupling the operating member to the contact rods, and this means comprises a plurality of insulating operating rods, each connected at one end to the operating member and at its opposite end to one of the movable contact rods. The operating rods are of substantially equal length and have longitudinal axes that converge and intersect at substantially a common point.

  12. Transient current interruption mechanism in a magnetically delayed vacuum switch

    NASA Technical Reports Server (NTRS)

    Morris, Gibson, Jr.; Dougal, Roger A.

    1993-01-01

    The capacity of a magnetically delayed vacuum switch to conduct current depends on the density of plasma injected into the switch. Exceeding the current capacity results in the switch entering a lossy mode of operation characterized by a transient interruption of the main current (opening behavior) and a rapid increase of voltage across the vacuum gap. Streak and framing photographs of the discharge indicate that a decrease of luminosity near the middle of the gap preceeds the transition to the opening phase. The zone of low luminosity propagates toward the cathode. This evidence suggests that the mechanism causing the opening phase is erosion of the background plasma in a manner similar to that in a plasma-opening switch. The resulting ion depletion forces a space-charge-limited conduction mode. The switch inductance maintains a high discharge current even during the space-charge-limited conduction phase, thus producing high internal fields. The high accelerating voltage, in turn, produces electron and ion beams that heat the electrode surfaces. As a result of the heating, jets of electrode vapor issue from the electrodes, either cathode or anode, depending on the selection of electrode materials.

  13. Vacuum-driven power-free microfluidics utilizing the gas solubility or permeability of polydimethylsiloxane (PDMS).

    PubMed

    Xu, Linfeng; Lee, Hun; Jetta, Deekshitha; Oh, Kwang W

    2015-10-21

    Suitable pumping methods for flow control remain a major technical hurdle in the path of biomedical microfluidic systems for point-of-care (POC) diagnostics. A vacuum-driven power-free micropumping method provides a promising solution to such a challenge. In this review, we focus on vacuum-driven power-free microfluidics based on the gas solubility or permeability of polydimethylsiloxane (PDMS); degassed PDMS can restore air inside itself due to its high gas solubility or gas permeable nature. PDMS allows the transfer of air into a vacuum through it due to its high gas permeability. Therefore, it is possible to store or transfer air into or through the gas soluble or permeable PDMS in order to withdraw liquids into the embedded dead-end microfluidic channels. This article provides a comprehensive look at the physics of the gas solubility and permeability of PDMS, a systematic review of different types of vacuum-driven power-free microfluidics, and guidelines for designing solubility-based or permeability-based PDMS devices, alongside existing applications. Advanced topics and the outlook in using micropumping that utilizes the gas solubility or permeability of PDMS will be also discussed. We strongly recommend that microfluidics and lab-on-chip (LOC) communities harness vacuum energy to develop smart vacuum-driven microfluidic systems.

  14. The Voltage Distribution Characteristics of a Hybrid Circuit Breaker During High Current Interruption

    NASA Astrophysics Data System (ADS)

    Cheng, Xian; Duan, Xiongying; Liao, Minfu; Huang, Zhihui; Luo, Yan; Zou, Jiyan

    2013-08-01

    Hybrid circuit breaker (HCB) technology based on a vacuum interrupter and a SF6 interrupter in series has become a new research direction because of the low-carbon requirements for high voltage switches. The vacuum interrupter has an excellent ability to deal with the steep rising part of the transient recovery voltage (TRV), while the SF6 interrupter can withstand the peak part of the voltage easily. An HCB can take advantage of the interrupters in the current interruption process. In this study, an HCB model based on the vacuum ion diffusion equations, ion density equation, and modified Cassie-Mayr arc equation is explored. A simulation platform is constructed by using a set of software called the alternative transient program (ATP). An HCB prototype is also designed, and the short circuit current is interrupted by the HCB under different action sequences of contacts. The voltage distribution of the HCB is analyzed through simulations and tests. The results demonstrate that if the vacuum interrupter withstands the initial TRV and interrupts the post-arc current first, then the recovery speed of the dielectric strength of the SF6 interrupter will be fast. The voltage distribution between two interrupters is determined by their post-arc resistance, which happens after current-zero, and subsequently, it is determined by the capacitive impedance after the post-arc current decays to zero.

  15. The Studies of a Vacuum Gap Breakdown after High-Current Arc Interruption with Increasing the Voltage

    NASA Astrophysics Data System (ADS)

    Schneider, A. V.; Popov, S. A.; Batrakov, A. V.; Dubrovskaya, E. L.; Lavrinovich, V. A.

    2017-12-01

    Vacuum-gap breakdown has been studied after high-current arc interruption with a subsequent increase in the transient recovery voltage across a gap. The effects of factors, such as the rate of the rise in the transient voltage, the potential of the shield that surrounds a discharge gap, and the arc burning time, have been determined. It has been revealed that opening the contacts earlier leads to the formation of an anode spot, which is the source of electrode material vapors into the discharge gap after current zero moment. Under the conditions of increasing voltage, this fact results in the breakdown. Too late opening leads to the breakdown of a short gap due to the high electric fields.

  16. Cathode surface effects and H.F.-behaviour of vacuum arcs

    NASA Astrophysics Data System (ADS)

    Fu, Yan Hong

    To gain a better understanding of the essential processes occurring during a vacuum arc interruption for the further development of the vacuum arc circuit breaker, cathode spot behavior, current interruption, dielectrical recovery and overvoltage generation are investigated. An experimental study on cathode spot behavior of the DC vacuum arc in relation to cathode surface roughness and a qualitative physical model to interpret the results are reported. An experimental investigation on the High Frequency (HF) current interruption, multiple recognitions and voltage escalation phenomena is reported. A calculation program to predict the level of overvoltages generated by the operation of a vacuum breaker in a realistic single phase circuit is developed. Detailed results are summarized.

  17. The Relationship between the Current Waveform just before the Current Zero and the Interruption Ability in the High-speed VCB

    NASA Astrophysics Data System (ADS)

    Niwa, Yoshimitsu; Matsuzaki, Jun; Yokokura, Kunio

    The high-speed vacuum circuit breaker, which forced the fault current to zero was investigated. The test circuit breaker consisted of a vacuum interrupter and a high frequency current source. The vacuum interrupter, which had the axial magnetic field electrode and the disk shape electrode, was tested. The arcing period of the high-speed vacuum circuit breaker is much shorter than that of conventional circuit breaker. The arc behavior of the test electrodes immediately after the contact separation was observed by a high-speed video camcorder. The relation between the current waveform just before the current zero and the interruption ability by varying the high frequency current source was investigated experimentally. The results demonstrate the interruption ability and the arc behavior of the high-speed vacuum circuit breaker. The high current interruption was made possible by the low current period just before the current zero, although the arcing time is short and the arc is concentrated.

  18. Proceedings of the twenty sixth international symposium on discharges and electrical insulation in vacuum. V. 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    2014-07-01

    Vacuum science and technology has made vital contributions in high technology areas like space, high energy particle accelerators, plasma devices, pulse power, electronics, vacuum interrupters, thin films, melting and refining of metals/alloys, extraction and processing of advanced materials. Vacuum discharges, vacuum arc physics and technology and various applications towards vacuum interrupters, pulse power and particle accelerator are the main themes for this symposium. Papers relevant to INIS are indexed separately.

  19. Proceedings of the twenty sixth international symposium on discharges and electrical insulation in vacuum. V. 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    2014-07-01

    Vacuum science and technology has made vital contributions in high technology areas like space, high energy particle accelerators, plasma devices, pulse power, electronics, vacuum interrupters, thin films, melting and refining of metals/alloys, extraction and processing of advanced materials. Vacuum discharges, vacuum arc physics and technology and various applications towards vacuum interrupters, pulse power and particle accelerator are the main themes for this symposium. Papers relevant to INIS are indexed separately.

  20. Supporting interruption management and multimodal interface design: three meta-analyses of task performance as a function of interrupting task modality.

    PubMed

    Lu, Sara A; Wickens, Christopher D; Prinet, Julie C; Hutchins, Shaun D; Sarter, Nadine; Sebok, Angelia

    2013-08-01

    The aim of this study was to integrate empirical data showing the effects of interrupting task modality on the performance of an ongoing visual-manual task and the interrupting task itself. The goal is to support interruption management and the design of multimodal interfaces. Multimodal interfaces have been proposed as a promising means to support interruption management.To ensure the effectiveness of this approach, their design needs to be based on an analysis of empirical data concerning the effectiveness of individual and redundant channels of information presentation. Three meta-analyses were conducted to contrast performance on an ongoing visual task and interrupting tasks as a function of interrupting task modality (auditory vs. tactile, auditory vs. visual, and single modality vs. redundant auditory-visual). In total, 68 studies were included and six moderator variables were considered. The main findings from the meta-analyses are that response times are faster for tactile interrupting tasks in case of low-urgency messages.Accuracy is higher with tactile interrupting tasks for low-complexity signals but higher with auditory interrupting tasks for high-complexity signals. Redundant auditory-visual combinations are preferable for communication tasks during high workload and with a small visual angle of separation. The three meta-analyses contribute to the knowledge base in multimodal information processing and design. They highlight the importance of moderator variables in predicting the effects of interruption task modality on ongoing and interrupting task performance. The findings from this research will help inform the design of multimodal interfaces in data-rich, event-driven domains.

  1. Optical Analysis Of The Vacuum Arc Plasma Generated In Cup-Shape Contacts

    NASA Astrophysics Data System (ADS)

    Pavelescu, G.; Pavelescu, D.; Dumitrescu, G.; Anghelita, P.; Gherendi, F.

    2007-04-01

    In this paper are presented the results of the optical analysis on the rotating arc plasma, generated in the vacuum low voltage circuit breaker with cup-shaped contacts. An adequate experimental setup was used for single shot time and spatial resolved spectroscopy in order to analyze the evolution of the vacuum arc plasma. Different current interruption situations are correlated with plasma spectral diagnosis. The study is aimed to contribute to a better understanding of the complex phenomena that take place in the interruption process of high currents that appears in the short-circuit regime of electrical networks.

  2. First Observations of Laser-Driven Acceleration of Relativistic Electrons in a Semi-Infinite Vacuum Space

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Plettner, T.; Byer, R.L.; Smith, T.I.

    2006-02-17

    We have observed acceleration of relativistic electrons in vacuum driven by a linearly polarized visible laser beam incident on a thin gold-coated reflective boundary. The observed energy modulation effect follows all the characteristics expected for linear acceleration caused by a longitudinal electric field. As predicted by the Lawson-Woodward theorem the laser driven modulation only appears in the presence of the boundary. It shows a linear dependence with the strength of the electric field of the laser beam and also it is critically dependent on the laser polarization. Finally, it appears to follow the expected angular dependence of the inverse transitionmore » radiation process. experiment as the Laser Electron Accelerator Project (LEAP).« less

  3. Driven to distraction: The nature and apparent purpose of interruptions in critical care and implications for HIT.

    PubMed

    Mamykina, Lena; Carter, Eileen J; Sheehan, Barbara; Stanley Hum, R; Twohig, Bridget C; Kaufman, David R

    2017-05-01

    To examine the apparent purpose of interruptions in a Pediatric Intensive Care Unit and opportunities to reduce their burden with informatics solutions. In this prospective observational study, researchers shadowed clinicians in the unit for one hour at a time, recording all interruptions participating clinicians experienced or initiated, their starting time, duration, and a short description that could help to infer their apparent purpose. All captured interruptions were classified inductively on their source and apparent purpose and on the optimal representational media for fulfilling their apparent purpose. The researchers observed thirty-four one-hour sessions with clinicians in the unit, including 21 nurses and 13 residents and house physicians. The physicians were interrupted on average 11.9 times per hour and interrupted others 8.8 times per hour. Nurses were interrupted 8.6 times per hour and interrupted others 5.1 times per hour. The apparent purpose of interruptions included Information Seeking and Sharing (n=259, 46.3%), Directives and Requests (n=70, 12%), Shared Decision-Making (n=49, 8.8%), Direct Patient Care (n=36, 6.4%), Social (n=71, 12.7%), Device Alarms (n=28, 5%), and Non-Clinical (n=10, 1.8%); 6.6% were not classified due to insufficient description. Of all captured interruptions, 29.5% were classified as being better served with informational displays or computer-mediated communication. Deeper understanding of the purpose of interruptions in critical care can help to distinguish between interruptions that require face-to-face conversation and those that can be eliminated with informatics solutions. The proposed taxonomy of interruptions and representational analysis can be used to further advance the science of interruptions in clinical care. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Metal vapor vacuum arc switching - Applications and results. [for launchers

    NASA Technical Reports Server (NTRS)

    Cope, D.; Mongeau, P.

    1984-01-01

    The design of metal-vapor vacuum-arc switches (MVSs) for electromagnetic launchers is discussed, and preliminary results are presented for an experimental MVS. The general principles of triggered-vacuum-gap and vacuum-interrupter MVSs are reviewed, and the requirements of electromagnetic launchers are analyzed. High-current design problems such as electrode erosion, current sharing, magnetic effects, and thermal effects are examined. The experimental MVS employs stainless-steel flanges, a glass vacuum vessel, an adjustable electrode gap, autonomous internal magnetic-field coils, and a tungsten-pin trigger assembly. Some results from tests without magnetic augmentation are presented graphically.

  5. Interruptions in a level one trauma center: a case study.

    PubMed

    Brixey, Juliana J; Tang, Zhihua; Robinson, David J; Johnson, Craig W; Johnson, Todd R; Turley, James P; Patel, Vimla L; Zhang, Jiajie

    2008-04-01

    The emergency department has been characterized as interrupt-driven. Government agencies and patient safety organizations recognize that interruptions contribute to medical errors. The purpose of this study was to observe, record, and contextualize activities and interruptions experienced by physicians and Registered Nurses (RNs) working in a Level One Trauma Center. A case study that relied on an ethnographic study design using the shadowing method. A convenience sample of physicians and RNs, each with at least 6 months of experience in the Emergency Department (ED), were asked to participate. In these kinds of detailed qualitative investigations, it is quite common to have a small sample size. Ethical approval: Approval was obtained from institutional ethic committees prior to initiating the study. Community consent was obtained from the ED staff through in-service education. All observations were made in the trauma section of the ED of a tertiary teaching hospital. The hospital is situated in a major medical center in the Gulf Coast region of the United States of America (USA). Five attending ED physicians were observed for a total of 29h, 31min. Eight RNs were shadowed for a total of 40 h, 9min. Interruptions and activities were categorized using the Hybrid Method to Categorize Interruptions and Activities (HyMCIA). Registered Nurses received slightly more interruptions per hour than physicians. People, pagers, and telephones were identified as mediums through which interruptions were delivered. The physical environment was found to contribute to interruptions in workflow because of physical design and when supplies were not available. Physicians and RNs usually returned to the original, interrupted activity more often than leaving the activity unfinished. This research provides an enhanced understanding of interruptions in workflow in the ED, the identification of work constraints, and the need to develop interventions to manage interruptions. It is crucial

  6. A socio-technical systems approach to studying interruptions: understanding the interrupter's perspective.

    PubMed

    Rivera, A Joy

    2014-05-01

    The purpose of this study was to understand the cognitive processes underlying nurses' decision to interrupt other nurses. The Institute of Medicine (2000) reported that interruptions are likely contributors to medical errors. Unfortunately, the research to date has been quite homogenous, focusing only on the healthcare provider being interrupted, ignoring the true complexities of interruptions. This study took a socio-technical approach being the first to examine interruptions from the viewpoint of the interrupting nurse. Over 15 h of observations and 10 open-ended interviews with expert nurses in a Neuroscience Surgical Intensive Care Unit were conducted. It was found that nurses conduct a quick cost-benefit assessment to determine the interruptibility of other nurses and whether an interruption is value-added vs. non-value added. To complete the assessment, nurses consider several conditional factors related to the interruptee, the interrupter, and the nature of the interruption content, and different potential consequences of the interruption. Published by Elsevier Ltd.

  7. Insulation Technology in Dry Air and Vacuum for a 72kV Low Pressured Dry Air Insulated Switchgear

    NASA Astrophysics Data System (ADS)

    Yoshida, Tadahiro; Koga, Hiromi; Harada, Takakazu; Miki, Shinichi; Arioka, Masahiro; Sato, Shinji; Yoshida, Satoru; Inoue, Naoaki; Maruyama, Akihiko; Takeuchi, Toshie

    A new 72kV rated low pressured dry air insulated switchgear applying electromagnetic actuation and function that supports CBM has been developed. First, dielectric characteristics in dry air under lightning impulse application has been investigated at bare and insulator covered electrodes. Dependence of the breakdown electric field strength on the effective area has been clarified to apply the configuration design of the insulation mold for the vacuum interrupter. In addition, moisture volume dependence on surface resistance has been clarified to decide moisture volume in gas pressure tank. Next, a new vacuum circuit breaker (VCB) has been designed. To keep dimensions from former 72kV SF6 gas insulated switchgear, distance between contacts in vacuum interrupter is needed to be shorter than that of former switchgear. Voltage withstand capability between electrodes practically designed for vacuum interrupter has been investigated under dc voltage application simulated the small capacitive current breaking test. Gap configuration including contacts and slits has been optimized and distance has been shortened 11% from former switchgear. As a result, the new low pressured dry air insulated switchgear has been designed comparably in outer size to former SF6 gas insulated switchgear. Using dry air as an insulation medium with low pressure has been able to reduce the environmental burden.

  8. Vacuum phonon tunneling.

    PubMed

    Altfeder, Igor; Voevodin, Andrey A; Roy, Ajit K

    2010-10-15

    Field-induced phonon tunneling, a previously unknown mechanism of interfacial thermal transport, has been revealed by ultrahigh vacuum inelastic scanning tunneling microscopy (STM). Using thermally broadened Fermi-Dirac distribution in the STM tip as in situ atomic-scale thermometer we found that thermal vibrations of the last tip atom are effectively transmitted to sample surface despite few angstroms wide vacuum gap. We show that phonon tunneling is driven by interfacial electric field and thermally vibrating image charges, and its rate is enhanced by surface electron-phonon interaction.

  9. Influence of the axial magnetic field on sheath development after current zero in a vacuum circuit breaker

    NASA Astrophysics Data System (ADS)

    Chen, Yi; Yang, Fei; Sun, Hao; Wu, Yi; Niu, Chunping; Rong, Mingzhe

    2017-06-01

    After current zero, which is the moment when the vacuum circuit breaker interrupts a vacuum arc, sheath development is the first process in the dielectric recovery process. An axial magnetic field (AMF) is widely used in the vacuum circuit breaker when the high-current vacuum arc is interrupted. Therefore, it is very important to study the influence of different AMF amplitudes on the sheath development. The objective of this paper is to study the influence of different AMF amplitudes on the sheath development from a micro perspective. Thus, the particle in cell-Monte Carlo collisions (PIC-MCC) method was adopted to develop the sheath development model. We compared the simulation results with the experimental results and then validated the simulation. We also obtained the speed of the sheath development and the energy density of the ions under different AMF amplitudes. The results showed that the larger the AMF amplitudes are, the faster the sheath develops and the lower the ion energy density is, meaning the breakdown is correspondingly more difficult.

  10. Vacuum status-display and sector-conditioning programs

    NASA Astrophysics Data System (ADS)

    Skelly, J.; Yen, S.

    1990-08-01

    Two programs have been developed for observation and control of the AGS vacuum system, which include the following notable features: (1) they incorporate a graphical user interface and (2) they are driven by a relational database which describes the vacuum system. The vacuum system comprises some 440 devices organized into 28 vacuum sectors. The status-display program invites menu selection of a sector, interrogates the relational database for relevant vacuum devices, acquires live readbacks and posts a graphical display of their status. The sector-conditioning program likewise invites sector selection, produces the same status display and also implements process control logic on the sector devices to pump the sector down from atmospheric pressure to high vacuum over a period extending several hours. As additional devices are installed in the vacuum system, the devices are added to the relational database; these programs then automatically include the new devices.

  11. Do interruptions affect quality of work?

    PubMed

    Foroughi, Cyrus K; Werner, Nicole E; Nelson, Erik T; Boehm-Davis, Deborah A

    2014-11-01

    The aim of this study was to determine if interruptions affect the quality of work. Interruptions are commonplace at home and in the office. Previous research in this area has traditionally involved time and errors as the primary measures of disruption. Little is known about the effect interruptions have on quality of work. Fifty-four students outlined and wrote three essays using a within-subjects design. During Condition 1, interruptions occurred while participants were outlining. During Condition 2, interruptions occurred while they were writing. No interruptions occurred in Condition 3. Quality of work was significantly reduced in both interruption conditions when compared to the non-interruption condition. The number of words produced was significantly reduced when participants were interrupted while writing the essay but not when outlining the essay. This research represents a crucial first step in understanding the effect interruptions have on quality of work. Our research suggests that interruptions negatively impact quality of work during a complex, creative writing task. Since interruptions are such a prevalent part of daily life, more research needs to be conducted to determine what other tasks are negatively impacted. Moreover, the underlying mechanism(s) causing these decrements needs to be identified. Finally, strategies and systems need to be designed and put in place to help counteract the decline in quality of work caused by interruptions.

  12. Investigating Interruptions: Implications for Flightdeck Performance

    NASA Technical Reports Server (NTRS)

    Latorella, Kara A.

    1999-01-01

    A fundamental aspect of multiple task management is attending to new stimuli and integrating associated task requirements into an ongoing task set; this is "interruption management" (IM). Anecdotal evidence and field studies indicate the frequency and consequences of interruptions, however experimental investigations of mechanisms influencing IM are scarce. Interruptions on commercial flightdecks are numerous, of various forms, and have been cited as contributing factors in many aviation incident and accident reports. This research grounds an experimental investigation of flightdeck interruptions in a proposed IM stage model. This model organizes basic research, identifies influencing mechanisms, and suggests appropriate dependent measures for IM. Fourteen airline pilots participated in a flightdeck simulation experiment to investigate the general effects of performing an interrupting task and interrupted procedure, and the effects of specific task factors: (1) modality; (2) embeddedness, or goal-level, of an interruption; (3) strength of association, or coupling-strength, between interrupted tasks; (4) semantic similarity; and (5) environmental stress. General effects of interruptions were extremely robust. All individual task factors significantly affected interruption management, except "similarity." Results extend the Interruption Management model, and are interpreted for their implications for interrupted flightdeck performance and intervention strategies for mitigating their effects on the flightdeck.

  13. Technical Trend of Environment-friendly High Voltage Vacuum Circuit Breaker (VCB)

    NASA Astrophysics Data System (ADS)

    Okubo, Hitoshi

    Vacuum Circuit Breakers (VCBs) have widely been used for low and medium voltage level, because of their high current interruption performance, maintenance free operations and environment-friendly characteristics. The VCB is now going to be applied to higher voltage systems for transmission and substation use. In this paper, the recent technical trend and future perspectives of high voltage VCBs are described, as well as their technical background.

  14. Review of 72.5kV double-break vacuum circuit breaker based on rapid repulsion actuator

    NASA Astrophysics Data System (ADS)

    Zhuofan, Tang; Lijun, Qin

    2017-07-01

    72.5kV double-break vacuum circuit breakers based on rapid repulsion actuator remain blank in China. Based on the theoretical analysis and experimental results from researchers, the design of 72.5kV double-break vacuum circuit breakers based on rapid repulsion actuator was presented. It takes the form of double-break, using two standard 40.5kV vacuum interrupter in series at the bottom, which adopt a permanent magnetic repulsion actuator. The permanent magnetic repulsion actuator consists of rapid repulsion actuator and magnetic retentivity actuator. On the basis above, we produced the prototype, and the superiority of the design was verified through the experiments.

  15. Parametrically driven hybrid qubit-photon systems: Dissipation-induced quantum entanglement and photon production from vacuum

    NASA Astrophysics Data System (ADS)

    Remizov, S. V.; Zhukov, A. A.; Shapiro, D. S.; Pogosov, W. V.; Lozovik, Yu. E.

    2017-10-01

    We consider a dissipative evolution of a parametrically driven qubit-cavity system under the periodic modulation of coupling energy between two subsystems, which leads to the amplification of counter-rotating processes. We reveal a very rich dynamical behavior of this hybrid system. In particular, we find that the energy dissipation in one of the subsystems can enhance quantum effects in another subsystem. For instance, optimal cavity decay assists the stabilization of entanglement and quantum correlations between qubits even in the steady state and the compensation of finite qubit relaxation. On the contrary, energy dissipation in qubit subsystems results in enhanced photon production from vacuum for strong modulation but destroys both quantum concurrence and quantum mutual information between qubits. Our results provide deeper insights to nonstationary cavity quantum electrodynamics in the context of quantum information processing and might be of importance for dissipative quantum state engineering.

  16. Interruptions disrupt reading comprehension.

    PubMed

    Foroughi, Cyrus K; Werner, Nicole E; Barragán, Daniela; Boehm-Davis, Deborah A

    2015-06-01

    Previous research suggests that being interrupted while reading a text does not disrupt the later recognition or recall of information from that text. This research is used as support for Ericsson and Kintsch's (1995) long-term working memory (LT-WM) theory, which posits that disruptions while reading (e.g., interruptions) do not impair subsequent text comprehension. However, to fully comprehend a text, individuals may need to do more than recognize or recall information that has been presented in the text at a later time. Reading comprehension often requires individuals to connect and synthesize information across a text (e.g., successfully identifying complex topics such as themes and tones) and not just make a familiarity-based decision (i.e., recognition). The goal for this study was to determine whether interruptions while reading disrupt reading comprehension when the questions assessing comprehension require participants to connect and synthesize information across the passage. In Experiment 1, interruptions disrupted reading comprehension. In Experiment 2, interruptions disrupted reading comprehension but not recognition of information from the text. In Experiment 3, the addition of a 15-s time-out prior to the interruption successfully removed these negative effects. These data suggest that the time it takes to process the information needed to successfully comprehend text when reading is greater than that required for recognition. Any interference (e.g., an interruption) that occurs during the comprehension process may disrupt reading comprehension. This evidence supports the need for transient activation of information in working memory for successful text comprehension and does not support LT-WM theory. (c) 2015 APA, all rights reserved).

  17. An architecture for intelligent task interruption

    NASA Technical Reports Server (NTRS)

    Sharma, D. D.; Narayan, Srini

    1990-01-01

    In the design of real time systems the capability for task interruption is often considered essential. The problem of task interruption in knowledge-based domains is examined. It is proposed that task interruption can be often avoided by using appropriate functional architectures and knowledge engineering principles. Situations for which task interruption is indispensable, a preliminary architecture based on priority hierarchies is described.

  18. Sozzy: a hormone-driven autonomous vacuum cleaner

    NASA Astrophysics Data System (ADS)

    Yamamoto, Masaki

    1994-02-01

    Domestic robots are promising examples of the application of robotics to personal life. There have been many approaches in this field, but no successful results exist. The problem is that domestic environments are more difficult for robots than other environments, such as factory floors or office floors. Consequently, conventional approaches using a model of human intelligence to design robots have not been successful. In this paper, we report on a prototyped domestic vacuum-cleaning robot that is designed to be able to handle complex environments. The control software is composed of two layers, both of which are generally inspired by behaviors of living creatures. The first layer corresponds to a dynamically reconfigurable system of behaviors implemented in the subsumption architecture. The ability of the robot to support alternate configurations of its behaviors provides the robot with increased robustness. We have conveniently labeled particular configurations as specific `emotions' according to the interpretation of observers of the robot's behavior. The second layer simulates the hormone system. The hormone system is modeled using state variables, increased or decreased by stimuli from the environment. The hormone condition selects the robot's most suitable emotion, according to the changing environments. The robot hardware is built of off-the-shelf parts, such as an embedded CPU, inexpensive home-appliance sensors, and small motors. These parts keep the total building cost to a minimum. The robot also has a vacuum cleaning function to demonstrate its capability to perform useful tasks. We tested the robot in our laboratory, and successfully videotaped its robust behaviors. We also confirmed the hormone system to enhance the robot's plasticity and lifelike quality.

  19. Understanding Emergency Medicine Physicians Multitasking Behaviors Around Interruptions.

    PubMed

    Fong, Allan; Ratwani, Raj M

    2018-06-11

    Interruptions can adversely impact human performance, particularly in fast-paced and high-risk environments such as the emergency department (ED). Understanding physician behaviors before, during, and after interruptions is important to the design and promotion of safe and effective workflow solutions. However, traditional human factors based interruption models do not accurately reflect the complexities of real-world environments like the ED and may not capture multiple interruptions and multitasking. We present a more comprehensive framework for understanding interruptions that is composed of three phases, each with multiple levels: Interruption Start Transition, Interruption Engagement, and Interruption End Transition. This three-phase framework is not constrained to discrete task transitions, providing a robust method to categorize multitasking behaviors around interruptions. We apply this framework in categorizing 457 interruption episodes. 457 interruption episodes were captured during 36 hours of observation. The interrupted task was immediately suspended 348 (76.1%) times. Participants engaged in new self-initiated tasks during the interrupting task 164 (35.9%) times and did not directly resume the interrupted task in 284 (62.1%) interruption episodes. Using this framework provides a more detailed description of the types of physician behaviors in complex environments. Understanding the different types of interruption and resumption patterns, which may have a different impact on performance, can support the design of interruption mitigation strategies. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  20. Global interrupt and barrier networks

    DOEpatents

    Blumrich, Matthias A.; Chen, Dong; Coteus, Paul W.; Gara, Alan G.; Giampapa, Mark E; Heidelberger, Philip; Kopcsay, Gerard V.; Steinmacher-Burow, Burkhard D.; Takken, Todd E.

    2008-10-28

    A system and method for generating global asynchronous signals in a computing structure. Particularly, a global interrupt and barrier network is implemented that implements logic for generating global interrupt and barrier signals for controlling global asynchronous operations performed by processing elements at selected processing nodes of a computing structure in accordance with a processing algorithm; and includes the physical interconnecting of the processing nodes for communicating the global interrupt and barrier signals to the elements via low-latency paths. The global asynchronous signals respectively initiate interrupt and barrier operations at the processing nodes at times selected for optimizing performance of the processing algorithms. In one embodiment, the global interrupt and barrier network is implemented in a scalable, massively parallel supercomputing device structure comprising a plurality of processing nodes interconnected by multiple independent networks, with each node including one or more processing elements for performing computation or communication activity as required when performing parallel algorithm operations. One multiple independent network includes a global tree network for enabling high-speed global tree communications among global tree network nodes or sub-trees thereof. The global interrupt and barrier network may operate in parallel with the global tree network for providing global asynchronous sideband signals.

  1. Analysis of Smartphone Interruptions on Academic General Internal Medicine Wards. Frequent Interruptions may cause a 'Crisis Mode' Work Climate.

    PubMed

    Vaisman, Alon; Wu, Robert C

    2017-01-04

    Hospital-based medical services are increasingly utilizing team-based pagers and smartphones to streamline communications. However, an unintended consequence may be higher volumes of interruptions potentially leading to medical error. There is likely a level at which interruptions are excessive and cause a 'crisis mode' climate. We retrospectively collected phone, text messaging, and email interruptions directed to hospital-assigned smartphones on eight General Internal Medicine (GIM) teams at two tertiary care centres in Toronto, Ontario from April 2013 to September 2014. We also calculated the number of times these interruptions exceeded a pre-specified threshold per hour, termed 'crisis mode', defined as at least five interruptions in 30 minutes. We analyzed the correlation between interruptions and date, site, and patient volumes. A total of 187,049 interruptions were collected over an 18-month period. Daily weekday interruptions rose sharply in the morning, peaking between 11 AM to 12 PM and measuring 4.8 and 3.7 mean interruptions/hour at each site, respectively. Mean daily interruptions per team totaled 46.2 ± 3.6 at Site 1 and 39.2 ± 4.2 at Site 2. The 'crisis mode' threshold was exceeded, on average, 2.3 times/day per GIM team during weekdays. In a multivariable linear regression analysis, site (β6.43 CI95% 5.44 - 7.42, p<0.001), day of the week (with Friday having the most interruptions) (β0.481 CI95% 0.236 - 0.730, p<0.05) and patient census (β1.55 CI95% 1.42 - 1.67, p<0.05) were all predictive of daily interruption volume although there was a significant interaction effect between site and patient census (β-0.941 CI95% -1.18 - -0.703, p<0.05). Interruptions were related to site-specific features, including volume, suggesting that future interventions should target the culture of individual hospitals. Excessive interruptions may have implications for patient safety especially when exceeding a maximal threshold over short periods of time.

  2. New hermetic sealing material for vacuum brazing of stainless steels

    NASA Astrophysics Data System (ADS)

    Hildebrandt, S.; Wiehl, G.; Silze, F.

    2016-03-01

    For vacuum brazing applications such as in vacuum interrupter industry Hermetic Sealing Materials (HSM) with low partial pressure are widely used. AgCu28 dominates the hermetic sealing market, as it has a very good wetting behavior on copper and metallized ceramics. Within recent decades wetting on stainless steel has become more and more important. However, today the silver content of HSMs is more in focus than in the past decades, because it has the biggest impact on the material prices. Umicore Technical Materials has developed a new copper based HSM, CuAg40Ga10. The wettability on stainless steel is significantly improved compared to AgCu28 and the total silver content is reduced by almost 44%. In this article the physical properties of the alloy and its brazed joints will be presented compared to AgCu28.

  3. Improvement of Thermal Interruption Capability in Self-blast Interrupting Chamber for New 245kV-50kA GCB

    NASA Astrophysics Data System (ADS)

    Shinkai, Takeshi; Koshiduka, Tadashi; Mori, Tadashi; Uchii, Toshiyuki; Tanaka, Tsutomu; Ikeda, Hisatoshi

    Current zero measurements are performed for 245kV-50kA-60Hz short line fault (L90) interruption tests with a self-blast interrupting chamber (double volume system) which has the interrupting capability up to 245kV-50kA-50Hz L90. Lower L90 interruption capability is observed for longer arcing time although very high pressure rise is obtained. It may be caused by higher blowing temperature and lower blowing density for longer arcing time. Interruption criteria and a optimization method of the chamber design are discussed to improve L90 interruption capability with it. The new chambers are designed at 245kV-50kA-60Hz to improve gas density in thermal volume for long arcing time. 245kV-50kA-60Hz L90 interruptions are performed with the new chamber. The suggested optimization method is an efficient tool for the self-blast interrupting chamber design although study of computing methods is required to calculate arc conductance around current zero as a direct criterion for L90 interruption capability with higher accuracy.

  4. Executing application function calls in response to an interrupt

    DOEpatents

    Almasi, Gheorghe; Archer, Charles J.; Giampapa, Mark E.; Gooding, Thomas M.; Heidelberger, Philip; Parker, Jeffrey J.

    2010-05-11

    Executing application function calls in response to an interrupt including creating a thread; receiving an interrupt having an interrupt type; determining whether a value of a semaphore represents that interrupts are disabled; if the value of the semaphore represents that interrupts are not disabled: calling, by the thread, one or more preconfigured functions in dependence upon the interrupt type of the interrupt; yielding the thread; and if the value of the semaphore represents that interrupts are disabled: setting the value of the semaphore to represent to a kernel that interrupts are hard-disabled; and hard-disabling interrupts at the kernel.

  5. [Dual chamber safety vacuum--initial experiences with a new suction cup].

    PubMed

    Korell, M; King, S; Hepp, H

    1994-06-01

    The main problem with vacuum extraction methods, alongside the cephalhaematoma produced, is the premature separation of the suction cup under traction, since the resulting sudden change in pressure can lead to severe intra-cerebral damage to the child. To reduce the risk of vaginal operative delivery, a new double-chamber safety vacuum extractor has been developed by Hepp/King. The basic feature of this instrument is an additional chamber with a thin overlapping area, which surrounds the actual suction cup and serves as a safety vacuum. If the suction cup starts to slip, the external vacuum is released and sounds an alarm. In addition, the inner vacuum has been designed to be convex and to reduce the volume of scalp, which is sucked into the vacuum, thus reducing the size of the cephalhaematoma produced. First experiences in clinical use demonstrated the reliability of the early warning signal, if the direction of traction is false or the applied traction is too strong. The inner vacuum remains constant at 0.8 atu, so that with care, the extraction can continue without interruption. We have used the new instrument in 18 deliveries. In 15 cases, the indication was failure to progress into the second stage of labour; in one case history of retinal detachment and in two cases signs of foetal asphyxia. In all cases, the child was delivered following one or two contractions with traction, without losing the vacuum. The average weight of the newborn was 3566 g. As expected, the cephalohaematoma produced was very much smaller than usual. Further clinical trials are necessary before the value of this new instrument can be assessed.

  6. Causes and occurrences of interruptions during ED triage.

    PubMed

    Johnson, Kimberly D; Motavalli, Michele; Gray, Dean; Kuehn, Connie

    2014-09-01

    Interruptions have been shown to cause errors and delays in the treatment of emergency patients and pose a real threat during the triage process. Missteps during the triage assessment can send a patient down the wrong treatment path and lead to delays. The purpose of this project was to identify the types and frequency of interruptions during the ED triage interview process. A focus group of emergency nurses was organized to identify the types of interruptions that commonly occur during the triage interview. These interruptions would be validated through observations in triage. A tally sheet was developed and implemented to determine how often each interruption occurred during an 8-hour shift. Triage nurses completed the tally sheets while working the first shift (7 am to 3 pm). This shift was selected because patient intake in the US Department of Veterans Affairs Emergency Department is highest during this time. The categories of interruptions identified included provision of conveniences to visitors, coworker-related interruptions, patient care-related interruptions, locating of family members in the emergency department, and other miscellaneous interruptions. Tally sheets were completed by the triage nurses during 10 shifts. On average, triage nurses were interrupted 48.2 times during an 8-hour shift (7 interruptions per hour). After reviewing the data, we found that only 22% of interruptions were related to patient care. More frequently, the causes of interruptions were not related to patient care: opening the door (33%), providing conveniences to visitors (21%), waiting patients or family members asking "How much longer?" (14%), and other causes (10%). Frequent interruptions can interfere with concentration and may affect patient care. Non-patient care-related interruptions not only can be frustrating to the triage nurse but also can be offensive to triage patients; they ultimately delay care and may even affect the quality of care. However, because scarce

  7. The time-course of recovery from interruption during reading: eye movement evidence for the role of interruption lag and spatial memory.

    PubMed

    Cane, James E; Cauchard, Fabrice; Weger, Ulrich W

    2012-01-01

    Two experiments examined how interruptions impact reading and how interruption lags and the reader's spatial memory affect the recovery from such interruptions. Participants read paragraphs of text and were interrupted unpredictably by a spoken news story while their eye movements were monitored. Time made available for consolidation prior to responding to the interruption did not aid reading resumption. However, providing readers with a visual cue that indicated the interruption location did aid task resumption substantially in Experiment 2. Taken together, the findings show that the recovery from interruptions during reading draws on spatial memory resources and can be aided by processes that support spatial memory. Practical implications are discussed.

  8. Thermally Driven Josephson Effect

    NASA Technical Reports Server (NTRS)

    Penanen, Konstantin; Chui, Talso

    2008-01-01

    A concept is proposed of the thermally driven Josephson effect in superfluid helium. Heretofore, the Josephson effect in a superfluid has been recognized as an oscillatory flow that arises in response to a steady pressure difference between two superfluid reservoirs separated by an array of submicron-sized orifices, which act in unison as a single Josephson junction. Analogously, the thermally driven Josephson effect is an oscillatory flow that arises in response to a steady temperature difference. The thermally driven Josephson effect is partly a consequence of a quantum- mechanical effect known as the fountain effect, in which a temperature difference in a superfluid is accompanied by a pressure difference. The thermally driven Josephson effect may have significance for the development of a high-resolution gyroscope based on the Josephson effect in a superfluid: If the pressure-driven Josephson effect were used, then the fluid on the high-pressure side would become depleted, necessitating periodic interruption of operation to reverse the pressure difference. If the thermally driven Josephson effect were used, there would be no net flow and so the oscillatory flow could be maintained indefinitely by maintaining the required slightly different temperatures on both sides of the junction.

  9. How to Interrupt Oppressive Behavior.

    ERIC Educational Resources Information Center

    McClintock, Mary

    1990-01-01

    Describes continuum of responses to examples of race-, handicap-, and sex discrimination by participants and staff of camping programs. Recommends following actions toward social justice: educating oneself; interrupting negative behavior; interrupting and educating; supporting proactive response; and initiating proactive response. Includes…

  10. Fast interrupt platform for extended DOS

    NASA Technical Reports Server (NTRS)

    Duryea, T. W.

    1995-01-01

    Extended DOS offers the unique combination of a simple operating system which allows direct access to the interrupt tables, 32 bit protected mode access to 4096 MByte address space, and the use of industry standard C compilers. The drawback is that fast interrupt handling requires both 32 bit and 16 bit versions of each real-time process interrupt handler to avoid mode switches on the interrupts. A set of tools has been developed which automates the process of transforming the output of a standard 32 bit C compiler to 16 bit interrupt code which directly handles the real mode interrupts. The entire process compiles one set of source code via a make file, which boosts productivity by making the management of the compile-link cycle very simple. The software components are in the form of classes written mostly in C. A foreground process written as a conventional application which can use the standard C libraries can communicate with the background real-time classes via a message passing mechanism. The platform thus enables the integration of high performance real-time processing into a conventional application framework.

  11. Efficient system interrupt concept design at the microprogramming level

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fakharzadeh, M.M.

    1989-01-01

    Over the past decade the demand for high speed super microcomputers has been tremendously increased. To satisfy this demand many high speed 32-bit microcomputers have been designed. However, the currently available 32-bit systems do not provide an adequate solution to many highly demanding problems such as in multitasking, and in interrupt driven applications, which both require context switching. Systems for these purposes usually incorporate sophisticated software. In order to be efficient, a high end microprocessor based system must satisfy stringent software demands. Although these microprocessors use the latest technology in the fabrication design and run at a very high speed,more » they still suffer from insufficient hardware support for such applications. All too often, this lack also is the premier cause of execution inefficiency. In this dissertation a micro-programmable control unit and operation unit is considered in an advanced design. An automaton controller is designed for high speed micro-level interrupt handling. Different stack models are designed for the single task and multitasking environment. The stacks are used for storage of various components of the processor during the interrupt calls, procedure calls, and task switching. A universal (as an example seven port) register file is designed for high speed parameter passing, and intertask communication in the multitasking environment. In addition, the register file provides a direct path between ALU and the peripheral data which is important in real-time control applications. The overall system is a highly parallel architecture, with no pipeline and internal cache memory, which allows the designer to be able to predict the processor's behavior during the critical times.« less

  12. Interruption Practice Reduces Errors

    DTIC Science & Technology

    2014-01-01

    dangers of errors at the PCS. Electronic health record systems are used to reduce certain errors related to poor- handwriting and dosage...10.16, MSE =.31, p< .05, η2 = .18 A significant interaction between the number of interruptions and interrupted trials suggests that trials...the variance when calculating whether a memory has a higher signal than interference. If something in addition to activation contributes to goal

  13. Microencapsulation and characterization of liposomal vesicles using a supercritical fluid process coupled with vacuum-driven cargo loading.

    PubMed

    Tsai, Wen-Chyan; Rizvi, Syed S H

    2017-06-01

    A new technique of liposomal microencapsulation, consisting of supercritical fluid extraction followed by rapid expansion of the supercritical solution and vacuum-driven cargo loading, was successfully developed. It is a continuous flow-through process without usage of any toxic organic solvent. For use as a coating material, the solubility of soy phospholipids in supercritical carbon dioxide was first determined using a dynamic equilibrium system and the data was correlated with the Chrastil model with good agreement. Liposomes were made with D-(+)-glucose as a cargo and their properties were characterized as functions of expansion pressure, temperature, and cargo loading rates. The highest encapsulation efficiency attained was 31.7% at the middle expansion pressure of 12.41MPa, highest expansion temperature of 90°C, and lowest cargo loading rate of 0.25mL/s. The large unilamellar vesicles and multivesicular vesicles were observed to be a majority of the liposomes produced using this eco-friendly process. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Vacuum compatible, high-speed, 2-D mirror tilt stage

    DOEpatents

    Denham; Paul E.

    2007-09-25

    A compact and vacuum compatible magnetic-coil driven tiltable stage that is equipped with a high efficiency reflective coating can be employed as a scanner in EUV applications. The drive electronics for the scanner is fully in situ programmable and rapidly switchable.

  15. Alaskan refiner raced against winter to relocate vacuum unit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gdula, L.M.; Wentworth, J.A.

    In late November 1994, San Antonio-based Tesoro Petroleum Corp. and Litwin Engineers and Constructors Inc. completed the relocation and refurbishment of a $25 million vacuum unit at Tesoro`s 72,000 b/d Kenai refinery. The addition of the vacuum distillation unit is a critical component in Tesoro`s market-driven strategy to enhance operating profits by maximizing production of higher-margin products such as gasoline and jet fuel. With its new vacuum distillation unit, Tesoro has reduced production of lower-value residual fuel oil while recovering more lighter, high-value material. The paper discusses the economic and strategic merits of purchasing and relocating an existing vacuum unit,more » the project schedule, new equipment, dismantling and transport, installation, tie-ins and start-up, products, operating changes, corrosion concerns, off gas, steam generation, design changes, environmental issues, reporting requirements, and accomplishments.« less

  16. Evaluation of Interruption Behavior by Naive Encoders.

    ERIC Educational Resources Information Center

    Coon, Christine A.; Schwanenflugel, Paula J.

    1996-01-01

    Determines the characteristics of interactions that influence judgments of interruption behavior in naive observers. Asks subjects to decide whether an example of an interruption was an interruption and then rate it in terms of how "good" or "bad" it was. Finds that naive observers use some of the same features described in…

  17. Interruption as a test of the user-computer interface

    NASA Technical Reports Server (NTRS)

    Kreifeldt, J. G.; Mccarthy, M. E.

    1981-01-01

    In order to study the effects different logic systems might have on interrupted operation, an algebraic calculator and a reverse polish notation calculator were compared when trained users were interrupted during problem entry. The RPN calculator showed markedly superior resistance to interruption effects compared to the AN calculator although no significant differences were found when the users were not interrupted. Causes and possible remedies for interruption effects are speculated. It is proposed that because interruption is such a common occurrence, it be incorporated into comparative evaluation tests of different logic system and control/display system and that interruption resistance be adopted as a specific design criteria for such design.

  18. Perceptual Learning of Interrupted Speech

    PubMed Central

    Benard, Michel Ruben; Başkent, Deniz

    2013-01-01

    The intelligibility of periodically interrupted speech improves once the silent gaps are filled with noise bursts. This improvement has been attributed to phonemic restoration, a top-down repair mechanism that helps intelligibility of degraded speech in daily life. Two hypotheses were investigated using perceptual learning of interrupted speech. If different cognitive processes played a role in restoring interrupted speech with and without filler noise, the two forms of speech would be learned at different rates and with different perceived mental effort. If the restoration benefit were an artificial outcome of using the ecologically invalid stimulus of speech with silent gaps, this benefit would diminish with training. Two groups of normal-hearing listeners were trained, one with interrupted sentences with the filler noise, and the other without. Feedback was provided with the auditory playback of the unprocessed and processed sentences, as well as the visual display of the sentence text. Training increased the overall performance significantly, however restoration benefit did not diminish. The increase in intelligibility and the decrease in perceived mental effort were relatively similar between the groups, implying similar cognitive mechanisms for the restoration of the two types of interruptions. Training effects were generalizable, as both groups improved their performance also with the other form of speech than that they were trained with, and retainable. Due to null results and relatively small number of participants (10 per group), further research is needed to more confidently draw conclusions. Nevertheless, training with interrupted speech seems to be effective, stimulating participants to more actively and efficiently use the top-down restoration. This finding further implies the potential of this training approach as a rehabilitative tool for hearing-impaired/elderly populations. PMID:23469266

  19. Effectiveness of a 'Do not interrupt' bundled intervention to reduce interruptions during medication administration: a cluster randomised controlled feasibility study.

    PubMed

    Westbrook, Johanna I; Li, Ling; Hooper, Tamara D; Raban, Magda Z; Middleton, Sandy; Lehnbom, Elin C

    2017-09-01

    To evaluate the effectiveness of a 'Do not interrupt' bundled intervention to reduce non-medication-related interruptions to nurses during medication administration. A parallel eight cluster randomised controlled study was conducted in a major teaching hospital in Adelaide, Australia. Four wards were randomised to the intervention which comprised wearing a vest when administering medications; strategies for diverting interruptions; clinician and patient education; and reminders. Control wards were blinded to the intervention. Structured direct observations of medication administration processes were conducted. The primary outcome was non-medication-related interruptions during individual medication dose administrations. The secondary outcomes were total interruption and multitasking rates. A survey of nurses' experiences was administered. Over 8 weeks and 364.7 hours, 227 nurses were observed administering 4781 medications. At baseline, nurses experienced 57 interruptions/100 administrations, 87.9% were unrelated to the medication task being observed. Intervention wards experienced a significant reduction in non-medication-related interruptions from 50/100 administrations (95% CI 45 to 55) to 34/100 (95% CI 30 to 38). Controlling for clustering, ward type and medication route showed a significant reduction of 15 non-medication-related interruptions/100 administrations compared with control wards. A total of 88 nurses (38.8%) completed the poststudy survey. Intervention ward nurses reported that vests were time consuming, cumbersome and hot. Only 48% indicated that they would support the intervention becoming hospital policy. Nurses experienced a high rate of interruptions. Few were related to the medication task, demonstrating considerable scope to reduce unnecessary interruptions. While the intervention was associated with a statistically significant decline in non-medication-related interruptions, the magnitude of this reduction and its likely impact on error

  20. Coping with interruptions in clinical nursing-A qualitative study.

    PubMed

    Laustsen, Sussie; Brahe, Liselotte

    2018-04-01

    To gain knowledge on how nurses' cope with interruptions in clinical practice. Interruptions may delay work routines and result in wasted time, disorganised planning and ineffective working procedures, affecting nurses' focus and overview in different ways. Research has identified a growing problem linking errors or adverse events with interruptions. It may affect patient safety if nurses are not paying attention to interruptions. Little is known about how nurses cope with interruptions DESIGN: The study was inspired by ethnographic fieldwork with a hermeneutical phenomenological approach. Observations were performed combined with semi-structured qualitative interviews. Managing interruptions depend on level of competence, working environment, dialogue and matching of expectations, collegial roles and implicit rules. Working procedures impact on how nurses are exposed to unnecessary interruptions. The latter affects overview and the ability to put the foot down and decline being interrupted. Professional competencies for example prioritising, keeping focus and collaborating across disciplines are needed to cope with interruptions. Culture work and matching of expectations are important to reflect on and discuss personal- and group behaviour caused by interruptions. We need to focus on the role of each nurse in the professional team, types of personality and unspoken rules. Professional competencies for example prioritising, keeping focus and cooperating across disciplines are needed to cope with interruptions. Coping with interruptions is important for the nursing profession, quality of care and patient safety. Changing practice requires multidisciplinary cooperation accepting different agendas at personal, group and organisational levels. Nurses must understand the meaning and nature of different types of interruptions to develop coping strategies and maintain quality in care and patient safety in multidisciplinary teamwork. © 2018 John Wiley & Sons Ltd.

  1. Servicing a globally broadcast interrupt signal in a multi-threaded computer

    DOEpatents

    Attinella, John E.; Davis, Kristan D.; Musselman, Roy G.; Satterfield, David L.

    2015-12-29

    Methods, apparatuses, and computer program products for servicing a globally broadcast interrupt signal in a multi-threaded computer comprising a plurality of processor threads. Embodiments include an interrupt controller indicating in a plurality of local interrupt status locations that a globally broadcast interrupt signal has been received by the interrupt controller. Embodiments also include a thread determining that a local interrupt status location corresponding to the thread indicates that the globally broadcast interrupt signal has been received by the interrupt controller. Embodiments also include the thread processing one or more entries in a global interrupt status bit queue based on whether global interrupt status bits associated with the globally broadcast interrupt signal are locked. Each entry in the global interrupt status bit queue corresponds to a queued global interrupt.

  2. Vacuum electron acceleration by coherent dipole radiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Troha, A.L.; Van Meter, J.R.; Landahl, E.C.

    1999-07-01

    The validity of the concept of laser-driven vacuum acceleration has been questioned, based on an extrapolation of the well-known Lawson-Woodward theorem, which stipulates that plane electromagnetic waves cannot accelerate charged particles in vacuum. To formally demonstrate that electrons can indeed be accelerated in vacuum by focusing or diffracting electromagnetic waves, the interaction between a point charge and coherent dipole radiation is studied in detail. The corresponding four-potential exactly satisfies both Maxwell{close_quote}s equations and the Lorentz gauge condition everywhere, and is analytically tractable. It is found that in the far-field region, where the field distribution closely approximates that of a planemore » wave, we recover the Lawson-Woodward result, while net acceleration is obtained in the near-field region. The scaling of the energy gain with wave-front curvature and wave amplitude is studied systematically. {copyright} {ital 1999} {ital The American Physical Society}« less

  3. Vacuum thermal evaporation of polyaniline doped with camphor sulfonic acid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boyne, Devon; Menegazzo, Nicola; Pupillo, Rachel C.

    2015-05-15

    Intrinsically conducting polymers belong to a class of organic polymers with intriguing electronic and physical properties specifically for electro-optical applications. Significant interest into doped polyaniline (PAni) can be attributed to its high conductivity and environmental stability. Poor dissolution in most solvents has thus far hindered the successful integration of PAni into commercial applications, which in turn, has led to the investigations of various deposition and acidic doping methods. Physical vapor deposition methods, including D.C. magnetron sputtering and vacuum thermal evaporation, have shown exceptional control over physical film properties (thickness and morphology). However, resulting films are less conductive than films depositedmore » by conventional methods (i.e., spin and drop casting) due to interruption of the hyperconjugation of polymer chains. Specifically, vacuum thermal evaporation requires a postdoping process, which results in incorporation of impurities and oxidation of surface moieties. In this contribution, thermally evaporated films, sequentially doped by vacuum evaporation of an organic acid (camphorsulfonic acid, CSA) is explored. Spectroscopic evidence confirms the successful doping of PAni with CSA while physical characterization (atomic force microscopy) suggests films retain good morphology and are not damaged by the doping process. The procedure presented herein also combines other postpreparation methods in an attempt to improve conductivity and/or substrate adhesion.« less

  4. Evaluation and Impact of Workflow Interruptions During Robot-assisted Surgery.

    PubMed

    Allers, Jenna C; Hussein, Ahmed A; Ahmad, Nabeeha; Cavuoto, Lora; Wing, Joseph F; Hayes, Robin M; Hinata, Nobuyuki; Bisantz, Ann M; Guru, Khurshid A

    2016-06-01

    To analyze and categorize causes for interruptions during robot-assisted surgery. We analyzed 10 robot-assisted prostatectomies that were performed by 3 surgeons from October 2014 to June 2015. Interruptions to surgery were defined in terms of duration, stage of surgery, personnel involved, reasons, and impact of the interruption on the surgical workflow. The main reasons for interruptions included the following: console surgeons switching (29%); preparation of the surgical equipment, such as cleaning or changing the camera (29%) or an instrument (27%); or when a suture, stapler, or clip was needed (12%). The most common interruption duration was 10-29 seconds (47.6%), and the least common interruption duration was greater than 90 seconds (3.6%). Additionally, about 14% of the interruptions were considered avoidable, whereas the remaining 86% of interruptions were necessary for surgery. By identifying and analyzing interruptions, we can develop evidence-based strategies to improve operating room efficiency, lower costs, and advance patient safety. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Checklist interruption and resumption: A linguistic study

    NASA Technical Reports Server (NTRS)

    Linde, Charlotte; Goguen, Joseph

    1987-01-01

    This study forms part of a project investigating the relationships among the formal structure of aviation procedures, the ways in which the crew members are taught to execute them, and the ways in which thet are actually performed in flight. Specifically, this report examines the interactions between the performance of checklists and interruptions, considering both interruptions by radio communications and by other crew members. The data consists of 14 crews' performance of a full mission simulation of a higher ratio of checklist speech acts to all speech acts within the span of the performance of the checklist. Further, it is not number of interruptions but length of interruptions which is associated with crew performance quality. Use of explicit holds is also associated with crew performance.

  6. Assessment of teacher interruptions on learners during oral case presentations.

    PubMed

    Yang, Glen; Chin, Rachel

    2007-06-01

    Studies have only recently begun to investigate the effects of interruptions on physicians in the emergency department (ED). To determine the frequency and nature of interruptions by the training physician that occur when medical trainees do oral case presentations (OCPs) in the ED. This was an observational study. Learner OCPs to attending emergency physicians were observed in the ED of an urban Level 1 trauma center at a major teaching hospital. A single investigator followed attending physicians blinded to the study objective in a nonrandomized convenience sampling of all ED shifts, recording information regarding teacher interruptions during new patient presentations. Learners completed a brief questionnaire after each OCP. A total of 196 OCPs were observed. The mean (+/-SD) duration of OCPs was 3.30 (+/-1.85) minutes, and the mean (+/-SD) number of interruptions was 0.75 (+/-0.60) per minute and 2.49 (+/-1.95) per OCP. The number of interruptions (per OCP) and duration of OCP varied by learner level of training, with more experienced learners giving shorter presentations and being interrupted less often. Frequency (per minute) of interruptions did not vary by learner level. In 40.3% of OCPs, attending physicians interrupted to give an assessment and/or a plan before the learner had done so, but 8.3% of interrupted learners believed that teacher interruptions were "disruptive" to their OCP. Attending emergency physicians frequently interrupt learners during new patient OCPs, with the number of interruptions varying by learner level of training. Teacher interruptions appear to have minimal, if any, detrimental effect on the perceived effectiveness of OCPs as a learning experience.

  7. Systems and methods for analyzing liquids under vacuum

    DOEpatents

    Yu, Xiao-Ying; Yang, Li; Cowin, James P.; Iedema, Martin J.; Zhu, Zihua

    2013-10-15

    Systems and methods for supporting a liquid against a vacuum pressure in a chamber can enable analysis of the liquid surface using vacuum-based chemical analysis instruments. No electrical or fluid connections are required to pass through the chamber walls. The systems can include a reservoir, a pump, and a liquid flow path. The reservoir contains a liquid-phase sample. The pump drives flow of the sample from the reservoir, through the liquid flow path, and back to the reservoir. The flow of the sample is not substantially driven by a differential between pressures inside and outside of the liquid flow path. An aperture in the liquid flow path exposes a stable portion of the liquid-phase sample to the vacuum pressure within the chamber. The radius, or size, of the aperture is less than or equal to a critical value required to support a meniscus of the liquid-phase sample by surface tension.

  8. Testing Of Choiced Ceramics Cutting Tools At Irregular Interrupted Cut

    NASA Astrophysics Data System (ADS)

    Kyncl, Ladislav; Malotová, Šárka; Nováček, Pavel; Nicielnik, Henryk; Šoková, Dagmar; Hemžský, Pavel; Pitela, David; Holubjak, Jozef

    2015-12-01

    This article discusses the test of removable ceramic cutting inserts during machining irregular interrupted cut. Tests were performed on a lathe, with the preparation which simulated us the interrupted cut. By changing the number of plates mounted in a preparation it simulate us a regular or irregular interrupted cut. When with four plates it was regular interrupted cut, the remaining three variants were already irregular cut. It was examined whether it will have the irregular interrupted cutting effect on the insert and possibly how it will change life of inserts during irregular interrupted cut (variable delay between shocks).

  9. Opioid interruptions, pain, and withdrawal symptoms in nursing home residents.

    PubMed

    Redding, Sarah E; Liu, Sophia; Hung, William W; Boockvar, Kenneth S

    2014-11-01

    Interruptions in opioid use have the potential to cause pain relapse and withdrawal symptoms. The objectives of this study were to observe patterns of opioid interruption during acute illness in nursing home residents and examine associations between interruptions and pain and withdrawal symptoms. Patients from 3 nursing homes in a metropolitan area who were prescribed opioids were assessed for symptoms of pain and withdrawal by researchers blinded to opioid dosage received, using the Brief Pain Inventory Scale and the Clinical Opioid Withdrawal Scale, respectively, during prespecified time periods. The prespecified time periods were 2 weeks after onset of acute illness (eg, urinary tract infection), and 2 weeks after hospital admission and nursing home readmission, if they occurred. Opioid dosing was recorded and a significant interruption was defined as a complete discontinuation or a reduction in dose of >50% for ≥1 day. The covariates age, sex, race, comorbid conditions, initial opioid dose, and initial pain level were recorded. Symptoms pre- and post-opioid interruptions were compared and contrasted with those in a group without opioid interruptions. Sixty-six patients receiving opioids were followed for a mean of 10.9 months and experienced a total of 104 acute illnesses. During 64 (62%) illnesses, patients experienced any reduction in opioid dosing, with a mean (SD) dose reduction of 63.9% (29.9%). During 39 (38%) illnesses, patients experienced a significant opioid interruption. In a multivariable model, residence at 1 of the 3 nursing homes was associated with a lower risk of interruption (odds ratio = 0.073; 95% CI, 0.009 to 0.597; P < 0.015). In patients with interruptions, there were statistically insignificant changes in mean (SD) pain score (difference -0.50 [2.66]; 95% CI, -3.16 to 2.16) and withdrawal score (difference -0.91 [3.12]; 95% CI, -4.03 to 2.21) after the interruption as compared with before interruption. However, when compared with

  10. Interrupted Monosyllabic Words: The Effects of Ten Interruption Locations on Recognition Performance by Older Listeners with Sensorineural Hearing Loss.

    PubMed

    Wilson, Richard H; Sharrett, Kadie C

    2017-01-01

    Two previous experiments from our laboratory with 70 interrupted monosyllabic words demonstrated that recognition performance was influenced by the temporal location of the interruption pattern. The interruption pattern (10 interruptions/sec, 50% duty cycle) was always the same and referenced word onset; the only difference between the patterns was the temporal location of the on- and off-segments of the interruption cycle. In the first study, both young and older listeners obtained better recognition performances when the initial on-segment coincided with word onset than when the initial on-segment was delayed by 50 msec. The second experiment with 24 young listeners detailed recognition performance as the interruption pattern was incremented in 10-msec steps through the 0- to 90-msec onset range. Across the onset conditions, 95% of the functions were either flat or U-shaped. To define the effects that interruption pattern locations had on word recognition by older listeners with sensorineural hearing loss as the interruption pattern incremented, re: word onset, from 0 to 90 msec in 10-msec steps. A repeated-measures design with ten interruption patterns (onset conditions) and one uninterruption condition. Twenty-four older males (mean = 69.6 yr) with sensorineural hearing loss participated in two 1-hour sessions. The three-frequency pure-tone average was 24.0 dB HL and word recognition was ≥80% correct. Seventy consonant-vowel nucleus-consonant words formed the corpus of materials with 25 additional words used for practice. For each participant, the 700 interrupted stimuli (70 words by 10 onset conditions), the 70 words uninterrupted, and two practice lists each were randomized and recorded on compact disc in 33 tracks of 25 words each. The data were analyzed at the participant and word levels and compared to the results obtained earlier on 24 young listeners with normal hearing. The mean recognition performance on the 70 words uninterrupted was 91.0% with an

  11. Analysis of Smartphone Interruptions on Academic General Internal Medicine Wards

    PubMed Central

    C.Wu, Robert

    2017-01-01

    Summary Introduction Hospital-based medical services are increasingly utilizing team-based pagers and smartphones to streamline communications. However, an unintended consequence may be higher volumes of interruptions potentially leading to medical error. There is likely a level at which interruptions are excessive and cause a ‘crisis mode’ climate. Methods We retrospectively collected phone, text messaging, and email interruptions directed to hospital-assigned smartphones on eight General Internal Medicine (GIM) teams at two tertiary care centres in Toronto, Ontario from April 2013 to September 2014. We also calculated the number of times these interruptions exceeded a pre-specified threshold per hour, termed ‘crisis mode’, defined as at least five interruptions in 30 minutes. We analyzed the correlation between interruptions and date, site, and patient volumes. Results A total of 187,049 interruptions were collected over an 18-month period. Daily weekday interruptions rose sharply in the morning, peaking between 11 AM to 12 PM and measuring 4.8 and 3.7 mean interruptions/hour at each site, respectively. Mean daily interruptions per team totaled 46.2 ± 3.6 at Site 1 and 39.2 ± 4.2 at Site 2. The ‘crisis mode’ threshold was exceeded, on average, 2.3 times/day per GIM team during weekdays. In a multivariable linear regression analysis, site (β6.43 CI95% 5.44 – 7.42, p<0.001), day of the week (with Friday having the most interruptions) (β0.481 CI95% 0.236 – 0.730, p<0.05) and patient census (β1.55 CI95% 1.42 – 1.67, p<0.05) were all predictive of daily interruption volume although there was a significant interaction effect between site and patient census (β-0.941 CI95% -1.18 – -0.703, p<0.05). Conclusion Interruptions were related to site-specific features, including volume, suggesting that future interventions should target the culture of individual hospitals. Excessive interruptions may have implications for patient safety especially when

  12. Well-posedness of the plasma-vacuum interface problem

    NASA Astrophysics Data System (ADS)

    Secchi, Paolo; Trakhinin, Yuri

    2014-01-01

    We consider the free-boundary problem for the plasma-vacuum interface in ideal compressible magnetohydrodynamics (MHD). In the plasma region the flow is governed by the usual compressible MHD equations, while in the vacuum region we consider the pre-Maxwell dynamics for the magnetic field. At the free interface, driven by the plasma velocity, the total pressure is continuous and the magnetic field on both sides is tangent to the boundary. The plasma-vacuum system is not isolated from the outside world, because of a given surface current on the fixed boundary that forces oscillations. Under a suitable stability condition satisfied at each point of the initial interface, stating that the magnetic fields on either side of the interface are not collinear, we show the existence and uniqueness of the solution to the nonlinear plasma-vacuum interface problem in suitable anisotropic Sobolev spaces. The proof is based on the results proved in the companion paper (Secchi and Trakhinin 2013 Interfaces Free Boundaries 15 323-57), about the well-posedness of the homogeneous linearized problem and the proof of a basic a priori energy estimate. The proof of the resolution of the nonlinear problem given in the present paper follows from the analysis of the elliptic system for the vacuum magnetic field, a suitable tame estimate in Sobolev spaces for the full linearized equations, and a Nash-Moser iteration.

  13. PAs reduce rounding interruptions in the pediatric intensive care unit.

    PubMed

    Hascall, Rebecca L; Perkins, R Serene; Kmiecik, Lauren; Gupta, Priya R; Shelak, Carolyn F; Demirel, Shaban; Buchholz, Mark T

    2018-06-01

    We investigated the proportion of encounters that were interrupted during family-centered rounds in the pediatric intensive care unit (PICU) to determine whether the use of a physician assistant (PA) significantly affected the proportion of interrupted encounters. We evaluated 2,657 rounding encounters in our 24-bed regional referral unit. The duration of each rounding encounter and total rounding duration were recorded. The presence or absence of a PA during each rounding encounter, the occurrence of an interruption, and other potential predictors of interruptions were recorded. The presence of a PA during PICU rounds was significantly associated (P < .001) with a 35.4% lower likelihood of an interruption. Family-centered rounds in the PICU are less likely to be interrupted when a PA is present. PAs help physicians and improve rounding efficiency by safely and effectively handling certain interruptions.

  14. Theory-driven, web-based, computer-tailored advice to reduce and interrupt sitting at work: development, feasibility and acceptability testing among employees.

    PubMed

    De Cocker, Katrien; De Bourdeaudhuij, Ilse; Cardon, Greet; Vandelanotte, Corneel

    2015-09-24

    Because of the adverse health effects in adults, interventions to influence workplace sitting, a large contributor to overall daily sedentary time, are needed. Computer-tailored interventions have demonstrated good outcomes in other health behaviours, though few have targeted sitting time at work. Therefore, the present aims were to (1) describe the development of a theory-driven, web-based, computer-tailored advice to influence sitting at work, (2) report on the feasibility of reaching employees, and (3) report on the acceptability of the advice. Employees from a public city service (n = 179) were invited by e-mail to participate. Employees interested to request the advice (n = 112) were sent the website link, a personal login and password. The online advice was based on different aspects of the Theory of Planned Behaviour, Self-Determination Theory and Self-Regulation Theory. Logistic regressions were conducted to compare characteristics (gender, age, education, employment status, amount of sitting and psychosocial correlates of workplace sitting) of employees requesting the advice (n = 90, 80.4%) with those who did not. Two weeks after visiting the website, 47 employees (52.2%) completed an online acceptability questionnaire. Those with a high education were more likely to request the advice than those with a low education (OR = 2.4, CI = 1.0-5.8), and those with a part-time job were more likely to request the advice compared to full-time employees (OR = 2.9, CI = 1.2-7.1). The majority found the advice interesting (n = 36/47, 76.6%), relevant (n = 33/47, 70.2%) and motivating (n = 29/47, 61.7%). Fewer employees believed the advice was practicable (n = 15/47, 31.9%). After completing the advice, 58.0% (n = 25/43) reported to have started interrupting their sitting and 32.6% (n = 17/43) additionally intended to do so; 14.0 % (n = 6/43) reported to have reduced their sitting and another 51.2% (n = 22/43) intended to do so. More efforts are needed to reach lower

  15. Vacuum force

    NASA Astrophysics Data System (ADS)

    Han, Yongquan

    2015-03-01

    To study on vacuum force, we must clear what is vacuum, vacuum is a space do not have any air and also ray. There is not exist an absolute the vacuum of space. The vacuum of space is relative, so that the vacuum force is relative. There is a certain that vacuum vacuum space exists. In fact, the vacuum space is relative, if the two spaces compared to the existence of relative vacuum, there must exist a vacuum force, and the direction of the vacuum force point to the vacuum region. Any object rotates and radiates. Rotate bend radiate- centripetal, gravity produced, relative gravity; non gravity is the vacuum force. Gravity is centripetal, is a trend that the objects who attracted wants to Centripetal, or have been do Centripetal movement. Any object moves, so gravity makes the object curve movement, that is to say, the radiation range curve movement must be in the gravitational objects, gravity must be existed in non vacuum region, and make the object who is in the region of do curve movement (for example: The earth moves around the sun), or final attracted in the form gravitational objects, and keep relatively static with attract object. (for example: objects on the earth moves but can't reach the first cosmic speed).

  16. The Effects of Career Interruptions on Young Men and Women.

    ERIC Educational Resources Information Center

    Shorten, Brett; Lewis, Donald E.

    1991-01-01

    Data from a sample of 5,837 Australians showed that (1) women had longer career interruptions; (2) regardless of number of interruptions, men had higher wages; (3) longer interruptions had a negative effect on reentry wages; and (4) 1985-88 growth in wages for males was enhanced by increased numbers and length of interruptions, with the opposite…

  17. Influence of a high vacuum on the precise positioning using an ultrasonic linear motor.

    PubMed

    Kim, Wan-Soo; Lee, Dong-Jin; Lee, Sun-Kyu

    2011-01-01

    This paper presents an investigation of the ultrasonic linear motor stage for use in a high vacuum environment. The slider table is driven by the hybrid bolt-clamped Langevin-type ultrasonic linear motor, which is excited with its different modes of natural frequencies in both lateral and longitudinal directions. In general, the friction behavior in a vacuum environment becomes different from that in an environment of atmospheric pressure and this difference significantly affects the performance of the ultrasonic linear motor. In this paper, to consistently provide stable and high power of output in a high vacuum, frequency matching was conducted. Moreover, to achieve the fine control performance in the vacuum environment, a modified nominal characteristic trajectory following control method was adopted. Finally, the stage was operated under high vacuum condition, and the operating performances were investigated compared with that of a conventional PI compensator. As a result, robustness of positioning was accomplished in a high vacuum condition with nanometer-level accuracy.

  18. Interrupted Visual Searches Reveal Volatile Search Memory

    ERIC Educational Resources Information Center

    Shen, Y. Jeremy; Jiang, Yuhong V.

    2006-01-01

    This study investigated memory from interrupted visual searches. Participants conducted a change detection search task on polygons overlaid on scenes. Search was interrupted by various disruptions, including unfilled delay, passive viewing of other scenes, and additional search on new displays. Results showed that performance was unaffected by…

  19. Practice increases procedural errors after task interruption.

    PubMed

    Altmann, Erik M; Hambrick, David Z

    2017-05-01

    Positive effects of practice are ubiquitous in human performance, but a finding from memory research suggests that negative effects are possible also. The finding is that memory for items on a list depends on the time interval between item presentations. This finding predicts a negative effect of practice on procedural performance under conditions of task interruption. As steps of a procedure are performed more quickly, memory for past performance should become less accurate, increasing the rate of skipped or repeated steps after an interruption. We found this effect, with practice generally improving speed and accuracy, but impairing accuracy after interruptions. The results show that positive effects of practice can interact with architectural constraints on episodic memory to have negative effects on performance. In practical terms, the results suggest that practice can be a risk factor for procedural errors in task environments with a high incidence of task interruption. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  20. Determining the Overall Impact of Interruptions during Online Testing

    ERIC Educational Resources Information Center

    Sinharay, Sandip; Wan, Ping; Whitaker, Mike; Kim, Dong-In; Zhang, Litong; Choi, Seung W.

    2014-01-01

    With an increase in the number of online tests, interruptions during testing due to unexpected technical issues seem unavoidable. For example, interruptions occurred during several recent state tests. When interruptions occur, it is important to determine the extent of their impact on the examinees' scores. There is a lack of research on this…

  1. Assessing Individual-Level Impact of Interruptions during Online Testing

    ERIC Educational Resources Information Center

    Sinharay, Sandip; Wan, Ping; Choi, Seung W.; Kim, Dong-In

    2015-01-01

    With an increase in the number of online tests, the number of interruptions during testing due to unexpected technical issues seems to be on the rise. For example, interruptions occurred during several recent state tests. When interruptions occur, it is important to determine the extent of their impact on the examinees' scores. Researchers such as…

  2. Progressive Care Nurses Improving Patient Safety by Limiting Interruptions During Medication Administration.

    PubMed

    Flynn, Fran; Evanish, Julie Q; Fernald, Josephine M; Hutchinson, Dawn E; Lefaiver, Cheryl

    2016-08-01

    Because of the high frequency of interruptions during medication administration, the effectiveness of strategies to limit interruptions during medication administration has been evaluated in numerous quality improvement initiatives in an effort to reduce medication administration errors. To evaluate the effectiveness of evidence-based strategies to limit interruptions during scheduled, peak medication administration times in 3 progressive cardiac care units (PCCUs). A secondary aim of the project was to evaluate the impact of limiting interruptions on medication errors. The percentages of interruptions and medication errors before and after implementation of evidence-based strategies to limit interruptions were measured by using direct observations of nurses on 2 PCCUs. Nurses in a third PCCU served as a comparison group. Interruptions (P < .001) and medication errors (P = .02) decreased significantly in 1 PCCU after implementation of evidence-based strategies to limit interruptions. Avoidable interruptions decreased 83% in PCCU1 and 53% in PCCU2 after implementation of the evidence-based strategies. Implementation of evidence-based strategies to limit interruptions in PCCUs decreases avoidable interruptions and promotes patient safety. ©2016 American Association of Critical-Care Nurses.

  3. Proposal of laser-driven automobile

    NASA Astrophysics Data System (ADS)

    Yabe, Takashi; Oozono, Hirokazu; Taniguchi, Kazumoto; Ohkubo, Tomomasa; Miyazaki, Sho; Uchida, Shigeaki; Baasandash, Choijil

    2004-09-01

    We propose an automobile driven by piston motion, which is driven by water-laser coupling. The automobile can load a solar-pumped fiber laser or can be driven by ground-based lasers. The vehicle is much useful for the use in other planet in which usual combustion engine cannot be used. The piston is in a closed system and then the water will not be exhausted into vacuum. In the preliminary experiment, we succeeded to drive the cylindrical piston of 0.2g (6mm in diameter) on top of water placed inside the acrylic pipe of 8 mm in inner diameter and the laser is incident from the bottom and focused onto the upper part of water by the lens (f=8mm) attached to the bottom edge.

  4. Traditions of research into interruptions in healthcare: A conceptual review.

    PubMed

    McCurdie, Tara; Sanderson, Penelope; Aitken, Leanne M

    2017-01-01

    Researchers from diverse theoretical backgrounds have studied workplace interruptions in healthcare, leading to a complex and conflicting body of literature. Understanding pre-existing viewpoints may advance the field more effectively than attempts to remove bias from investigations. To identify research traditions that have motivated and guided interruptions research, and to note research questions posed, gaps in approach, and possible avenues for future research. A critical review was conducted of research on interruptions in healthcare. Two researchers identified core research communities based on the community's motivations, philosophical outlook, and methods. Among the characteristics used to categorise papers into research communities were the predominant motivation for studying interruptions, the research questions posed, and key contributions to the body of knowledge on interruptions in healthcare. In cases where a paper approached an equal number of characteristics from two traditions, it was placed in a blended research community. A total of 141 papers were identified and categorised; all papers identified were published from 1994 onwards. Four principal research communities emerged: epidemiology, quality improvement, cognitive systems engineering (CSE), and applied cognitive psychology. Blends and areas of mutual influence between the research communities were identified that combine the benefits of individual traditions, but there was a notable lack of blends incorporating quality improvement initiatives. The question most commonly posed by researchers across multiple communities was: what is the impact of interruptions? Impact was measured as a function of task time or risk in the epidemiology tradition, situation awareness in the CSE tradition, or resumption lag (time to resume an interrupted task) in the applied cognitive psychology tradition. No single question about interruptions in healthcare was shared by all four of the core communities. Much

  5. The Effect of Interruption Duration and Demand on Resuming Suspended Goals

    ERIC Educational Resources Information Center

    Monk, Christopher A.; Trafton, J. Gregory; Boehm-Davis, Deborah A.

    2008-01-01

    The time to resume task goals after an interruption varied depending on the duration and cognitive demand of interruptions, as predicted by the memory for goals model (Altmann & Trafton, 2002). Three experiments using an interleaved tasks interruption paradigm showed that longer and more demanding interruptions led to longer resumption times in a…

  6. The Effect of Interruptions on Part 121 Air Carrier Operations

    NASA Technical Reports Server (NTRS)

    Damos, Diane L.

    1998-01-01

    The primary purpose of this study was to determine the relative priorities of various events and activities by examining the probability that a given activity was interrupted by a given event. The analysis will begin by providing frequency of interruption data by crew position (captain versus first officer) and event type. Any differences in the pattern of interruptions between the first officers and the captains will be explored and interpreted in terms of standard operating procedures. Subsequent data analyses will focus on comparing the frequency of interruptions for different types of activities and for the same activities under normal versus emergency conditions. Briefings and checklists will receive particular attention. The frequency with which specific activities are interrupted under multiple- versus single-task conditions also will be examined; because the majority of multiple-task data were obtained under laboratory conditions, LOFT-type tapes offer a unique opportunity to examine concurrent task performance under 'real-world' conditions. A second purpose of this study is to examine the effects of the interruptions on performance. More specifically, when possible, the time to resume specific activities will be compared to determine if pilots are slower to resume certain types of activities. Errors in resumption or failures to resume specific activities will be noted and any patterns in these errors will be identified. Again, particular attention will be given to the effects of interruptions on the completion of checklists and briefings. Other types of errors and missed events (i.e., the crew should have responded to the event but did not) will be examined. Any methodology using interruptions to examine task prioritization must be able to identify when an interruption has occurred and describe the ongoing activities that were interrupted. Both of these methodological problems are discussed In detail in the following section,

  7. Volcanic eruption induced WWVB transmission path interruption

    NASA Astrophysics Data System (ADS)

    Buckmaster, H. A.; Hansen, C. H.

    1985-07-01

    It is reported that the 60 kHz transmission of WWVB from Fort Collins, Colorado, was not received in Calgary, Alberta, Canada, for about 11 h from 1109 UT to 2153 UT on July 23, 1980. It is suggested that this transmission path interruption is correlated with the 15 km height ash cloud due to the July 22, 1980 volcanic eruption of Mount St. Helens as it drifted eastward interrupting both the ground- and first hop sky-wave paths and that this ash cloud is the source of the conductivity and/or ionization necessary to produce this interruption. Small phase retardations are also reported which could be correlated with other Mount St. Helens volcanic events during May-July 1980.

  8. HIV models for treatment interruption: Adaptation and comparison

    NASA Astrophysics Data System (ADS)

    Hillmann, Andreas; Crane, Martin; Ruskin, Heather J.

    2017-10-01

    In recent years, Antiretroviral Therapy (ART) has become commonplace for treating HIV infections, although a cure remains elusive, given reservoirs of replicating latently-infected cells, which are resistant to normal treatment regimes. Treatment interruptions, whether ad hoc or structured, are known to cause a rapid increase in viral production to detectable levels, but numerous clinical trials remain inconclusive on the dangers inherent in this resurgence. In consequence, interest in examining interruption strategies has recently been rekindled. This overview considers modelling approaches, which have been used to explore the issue of treatment interruption. We highlight their purpose and the formalisms employed and examine ways in which clinical data have been used. Implementation of selected models is demonstrated, illustrative examples provided and model performance compared for these cases. Possible extensions to bottom-up modelling techniques for treatment interruptions are briefly discussed.

  9. Interruptions in emergency medicine: things are not always what they seem.

    PubMed

    Walter, Scott R

    2018-06-20

    We have all felt the cognitive disjuncture of being interrupted during an important task. Most ED physicians will readily proffer the high frequency and/or burden of interruptions during their work, and of the many observational studies of interruptions in healthcare EDs do indeed have high interruption rates[2]. In experimental psychology, where many of these ideas originated, there is plenty of evidence that interruptions negatively affect performance. Interruptions have been associated with reduced performance on complex tasks[3,4], increased sequence errors[5], increased task completion time and augmented annoyance and anxiety[6]. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  10. Improving the effectiveness of an interruption lag by inducing a memory-based strategy.

    PubMed

    Morgan, Phillip L; Patrick, John; Tiley, Leyanne

    2013-01-01

    The memory for goals model (Altmann & Trafton, 2002) posits the importance of a short delay (the 'interruption lag') before an interrupting task to encode suspended goals for retrieval post-interruption. Two experiments used the theory of soft constraints (Gray, Simms, Fu & Schoelles, 2006) to investigate whether the efficacy of an interruption lag could be improved by increasing goal-state access cost to induce a more memory-based encoding strategy. Both experiments used a copying task with three access cost conditions (Low, Medium, and High) and a 5-s interruption lag with a no lag control condition. Experiment 1 found that the participants in the High access cost condition resumed more interrupted trials and executed more actions correctly from memory when coupled with an interruption lag. Experiment 2 used a prospective memory test post-interruption and an eyetracker recorded gaze activity during the interruption lag. The participants in the High access cost condition with an interruption lag were best at encoding target information during the interruption lag, evidenced by higher scores on the prospective memory measure and more gaze activity on the goal-state during the interruption lag. Theoretical and practical issues regarding the use of goal-state access cost and an interruption lag are discussed. Copyright © 2012. Published by Elsevier B.V.

  11. Modelling of crater formation on anode surface by high-current vacuum arcs

    NASA Astrophysics Data System (ADS)

    Tian, Yunbo; Wang, Zhenxing; Jiang, Yanjun; Ma, Hui; Liu, Zhiyuan; Geng, Yingsan; Wang, Jianhua; Nordlund, Kai; Djurabekova, Flyura

    2016-11-01

    Anode melting and crater formation significantly affect interruption of high-current vacuum arcs. The primary objective of this paper is to theoretically investigate the mechanism of anode surface crater formation, caused by the combined effect of surface heating during the vacuum arc and pressure exerted on the molten surface by ions and electrons from the arc plasma. A model of fluid flow and heat transfer in the arc anode is developed and combined with a magnetohydrodynamics model of the vacuum arc plasma. Crater formation is observed in simulation for a peak arcing current higher than 15 kA on 40 mm diam. Cu electrodes spaced 10 mm apart. The flow of liquid metal starts after 4 or 5 ms of arcing, and the maximum velocities are 0.95 m/s and 1.39 m/s for 20 kA and 25 kA arcs, respectively. This flow redistributes thermal energy, and the maximum temperature of the anode surface does not remain in the center. Moreover, the condition for the liquid droplet formation on the anode surfaces is developed. The solidification process after current zero is also analyzed. The solidification time has been found to be more than 3 ms after 25 kA arcing. The long solidification time and sharp features on crater rims induce Taylor cone formation.

  12. Workflow interruptions and mental workload in hospital pediatricians: an observational study.

    PubMed

    Weigl, Matthias; Müller, Andreas; Angerer, Peter; Hoffmann, Florian

    2014-09-24

    Pediatricians' workload is increasingly thought to affect pediatricians' quality of work life and patient safety. Workflow interruptions are a frequent stressor in clinical work, impeding clinicians' attention and contributing to clinical malpractice. We aimed to investigate prospective associations of workflow interruptions with multiple dimensions of mental workload in pediatricians during clinical day shifts. In an Academic Children's Hospital a prospective study of 28 full shift observations was conducted among pediatricians providing ward coverage. The prevalence of workflow interruptions was based on expert observation using a validated observation instrument. Concurrently, Pediatricians' workload ratings were assessed with three workload dimensions of the well-validated NASA-Task Load Index: mental demands, effort, and frustration. Observed pediatricians were, on average, disrupted 4.7 times per hour. Most frequent were interruptions by colleagues (30.2%), nursing staff (29.7%), and by telephone/beeper calls (16.3%). Interruption measures were correlated with two workload outcomes of interest: frequent workflow interruptions were related to less cognitive demands, but frequent interruptions were associated with increased frustration. With regard to single sources, interruptions by colleagues showed the strongest associations to workload. The findings provide insights into specific pathways between different types of interruptions and pediatricians' mental workload. These findings suggest further research and yield a number of work and organization re-design suggestions for pediatric care.

  13. 14 CFR 135.417 - Mechanical interruption summary report.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Mechanical interruption summary report. 135... Maintenance, Preventive Maintenance, and Alterations § 135.417 Mechanical interruption summary report. Each... unscheduled stop or diversion from a route, caused by known or suspected mechanical difficulties or...

  14. Avoidable interruptions during drug administration in an intensive rehabilitation ward: improvement project.

    PubMed

    Buchini, Sara; Quattrin, Rosanna

    2012-04-01

    To record the frequency of interruptions and their causes, to identify 'avoidable' interruptions and to build an improvement project to reduce 'avoidable' interruptions. In Italy each year 30,000-35,000 deaths per year are attributed to health-care system errors, of which 19% are caused by medication errors. The factors that contribute to drug management error also include interruptions and carelessness during treatment administration. A descriptive study design was used to record the frequency of interruptions and their causes and to identify 'avoidable' interruptions in an intensive rehabilitation ward in Northern Italy. A data collection grid was used to record the data over a 6-month period. A total of 3000 work hours were observed. During the study period 1170 interruptions were observed. The study identified 14 causes of interruption. The study shows that of the 14 cases of interruptions at least nine can be defined as 'avoidable'. An improvement project has been proposed to reduce unnecessary interruptions and distractions to avoid making errors. An additional useful step to reduce the incidence of treatment errors would be to implement the use of a single patient medication sheet for the recording of drug prescription, preparation and administration and also the incident reporting. © 2011 Blackwell Publishing Ltd.

  15. Indian Vacuum Society: The Indian Vacuum Society

    NASA Astrophysics Data System (ADS)

    Saha, T. K.

    2008-03-01

    The Indian Vacuum Society (IVS) was established in 1970. It has over 800 members including many from Industry and R & D Institutions spread throughout India. The society has an active chapter at Kolkata. The society was formed with the main aim to promote, encourage and develop the growth of Vacuum Science, Techniques and Applications in India. In order to achieve this aim it has conducted a number of short term courses at graduate and technician levels on vacuum science and technology on topics ranging from low vacuum to ultrahigh vacuum So far it has conducted 39 such courses at different parts of the country and imparted training to more than 1200 persons in the field. Some of these courses were in-plant training courses conducted on the premises of the establishment and designed to take care of the special needs of the establishment. IVS also regularly conducts national and international seminars and symposia on vacuum science and technology with special emphasis on some theme related to applications of vacuum. A large number of delegates from all over India take part in the deliberations of such seminars and symposia and present their work. IVS also arranges technical visits to different industries and research institutes. The society also helped in the UNESCO sponsored post-graduate level courses in vacuum science, technology and applications conducted by Mumbai University. The society has also designed a certificate and diploma course for graduate level students studying vacuum science and technology and has submitted a syllabus to the academic council of the University of Mumbai for their approval, we hope that some colleges affiliated to the university will start this course from the coming academic year. IVS extended its support in standardizing many of the vacuum instruments and played a vital role in helping to set up a Regional Testing Centre along with BARC. As part of the development of vacuum education, the society arranges the participation of

  16. Radiation therapy interruption in a poor resource setting: causes and management..

    PubMed

    Akinlade, B I; Folasire, A M; Elumelu-Kupoluyi, T N; Adenipekun, A A; Iyobosa, U B; Campbell, O B

    2014-12-01

    Treatment interruption is the failure to execute approved treatment plan of a patient. This adversely affects treatment outcomeif not properly managed. This retrospective study causes and management of radiation treatment interruptions during High Dose Rate Brachytherapy(HDRB) for carcinoma of the cervix in a teaching hospital in Nigeria. Five hundred patients with cervical carcinoma, who received HDRB, post external beam radiotherapy, between August, 2008 and July, 2013 were assessed. They were grouped into (A): those who experienced treatment interruption and (B): those who did not. Each patient was scheduled to receive three fractions of HDRB over 3 weeks. Those in groups A were assessed for the exact treatment fraction missed, the cause and duration of treatment interruption and the actions taken to compensate for non-execution of treatment. A total of 90 patients fall into group A and most (41) of them experienced interruptions in the third fraction of their treatment. The most frequent (44%) causes of treatment interruptions observed among them were patient-related. Record of compensation for treatment interruption was not found in patients' treatment folders. This action may be due to lack of functional procedures for managing treatment interruptions and insufficient follow-up of patients, who never came back for consideration for compensation. This study showed that radiation oncology centres need to review their policies for managing treatment interruptions and documentation. Also, the mechanism for patients' follow-up should be strengthened to a reasonable extent to achieve better radiotherapy care.

  17. Reducing the Disruptive Effects of Interruptions With Noninvasive Brain Stimulation.

    PubMed

    Blumberg, Eric J; Foroughi, Cyrus K; Scheldrup, Melissa R; Peterson, Matthew S; Boehm-Davis, Debbie A; Parasuraman, Raja

    2015-09-01

    The authors determine whether transcranial direct current stimulation (tDCS) can reduce resumption time when an ongoing task is interrupted. Interruptions are common and disruptive. Working memory capacity has been shown to predict resumption lag (i.e., time to successfully resume a task after interruption). Given that tDCS applied to brain areas associated with working memory can enhance performance, tDCS has the potential to improve resumption lag when a task is interrupted. Participants were randomly assigned to one of four groups that received anodal (active) stimulation of 2 mA tDCS to one of two target brain regions, left and right dorsolateral prefrontal cortex (DLPFC), or to one of two control areas, active stimulation of the left primary motor cortex or sham stimulation of the right DLPFC, while completing a financial management task that was intermittently interrupted with math problem solving. Anodal stimulation to the right and left DLPFC significantly reduced resumption lags compared to the control conditions (sham and left motor cortex stimulation). Additionally, there was no speed-accuracy tradeoff (i.e., the improvement in resumption time was not accompanied by an increased error rate). Noninvasive brain stimulation can significantly decrease resumption lag (improve performance) after a task is interrupted. Noninvasive brain stimulation offers an easy-to-apply tool that can significantly improve interrupted task performance. © 2014, Human Factors and Ergonomics Society.

  18. Development of Electromagnetically Actuated Vacuum Circuit Breaker for 72kV Rated Switchgear

    NASA Astrophysics Data System (ADS)

    Kim, Tae-Hyun; Tsukima, Mitsuru; Maruyama, Akihiko; Takahara, Osamu; Haruna, Kazushi; Yano, Tomotaka; Matsunaga, Toshihiro; Imamura, Kazuaki; Arioka, Masahiro; Takeuchi, Toshie

    A new electromagnetically actuated vacuum circuit breaker (VCB) has been developed for a 72kV rated switchgear. Each phase of this VCB has a plurality of compact electromagnetic actuators linked mechanically providing the required driving energy. The mechanical linkage working as a lever magnifies an actuator stroke to the required stroke of a 72kV rated vacuum interrupter. An electromagnetic analysis coupled with motion, which considers the mechanical linkage of the plural actuators, has been developed for designing the driving behavior of this VCB. Using this analytical method and a quality engineering method known as the Taguchi method, we have clarified effective parameters to reduce the time difference of the driving behavior for tolerance specifications. Moreover, analyzing the oscillatory behavior closing the contacts, a structure of this VCB has been designed to reduce the bounce duration. The developed new VCB has been confirmed that a time difference is short enough and bounce duration is reduced. This VCB is highly reliable against variations in manufacturing and environment.

  19. Medication administration and interruptions in nursing homes: A qualitative observational study.

    PubMed

    Odberg, Kristian Ringsby; Hansen, Britt Saetre; Aase, Karina; Wangensteen, Sigrid

    2018-03-01

    To contribute in-depth knowledge of the characteristics of medication administration and interruptions in nursing homes. The following research questions guided the study: How can the medication administration process in nursing homes be described? How can interruptions during the medication administration process in nursing homes be characterized? Medication administration is a vital process across healthcare settings, and earlier research in nursing homes is sparse. The medication administration process is prone to interruptions that may lead to adverse drug events. On the other hand, interruptions may also have positive effects on patient safety. A qualitative observational study design was applied. Data were collected using partial participant observations. An inductive content analysis was performed. Factors that contributed to the observed complexity of medication administration in nursing homes were the high number of single tasks, varying degree of linearity, the variability of technological solutions, demands regarding documentation and staff's apparent freedom as to how and where to perform medication-related activities. Interruptions during medication administration are prevalent and can be characterised as passive (e.g., alarm and background noises), active (e.g., discussions) or technological interruptions (e.g., use of mobile applications). Most interruptions have negative outcomes, while some have positive outcomes. A process of normalisation has taken place whereby staff put up with second-rate technological solutions, noise and interruptions when they are performing medication-related tasks. Before seeking to minimise interruptions during the medication administration process, it is important to understand the interconnectivity of the elements using a systems approach. Staff and management need to be aware of the normalisation of interruptions. Knowledge of the complexity of medication administration may raise awareness and highlight the importance

  20. Basic experiments during loss of vacuum event (LOVE) in fusion experimental reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ogawa, Masuro; Kunugi, Tomoaki; Seki, Yasushi

    If a loss of vacuum event (LOVE) occurs due to damage of the vacuum vessel of a nuclear fusion experimental reactor, some chemical reactions such as a graphic oxidation and a buoyancy-driven exchange flow take place after equalization of the gas pressure between the inside and outside of the vacuum vessel. The graphite oxidation would generate inflammable carbon monoxide and release tritium retained in the graphite. The exchange flow through the breaches may transport the carbon monoxide and tritium out of the vacuum vessel. To add confidence to the safety evaluations and analyses, it is important to grasp the basicmore » phenomena such as the exchange flow and the graphite oxidation. Experiments of the exchange flow and the graphite oxidation were carried out to obtain the exchange flow rate and the rate constant for the carbon monoxide combustion, respectively. These experimental results were compared with existing correlations. The authors plan a scaled-model test and a full-scale model test for the LOVE.« less

  1. An eye movement analysis of the effect of interruption modality on primary task resumption.

    PubMed

    Ratwani, Raj; Trafton, J Gregory

    2010-06-01

    We examined the effect of interruption modality (visual or auditory) on primary task (visual) resumption to determine which modality was the least disruptive. Theories examining interruption modality have focused on specific periods of the interruption timeline. Preemption theory has focused on the switch from the primary task to the interrupting task. Multiple resource theory has focused on interrupting tasks that are to be performed concurrently with the primary task. Our focus was on examining how interruption modality influences task resumption.We leverage the memory-for-goals theory, which suggests that maintaining an associative link between environmental cues and the suspended primary task goal is important for resumption. Three interruption modality conditions were examined: auditory interruption with the primary task visible, auditory interruption with a blank screen occluding the primary task, and a visual interruption occluding the primary task. Reaction time and eye movement data were collected. The auditory condition with the primary task visible was the least disruptive. Eye movement data suggest that participants in this condition were actively maintaining an associative link between relevant environmental cues on the primary task interface and the suspended primary task goal during the interruption. These data suggest that maintaining cue association is the important factor for reducing the disruptiveness of interruptions, not interruption modality. Interruption-prone computing environments should be designed to allow for the user to have access to relevant primary task cues during an interruption to minimize disruptiveness.

  2. Numerical modeling of high-voltage circuit breaker arcs and their interraction with the power system

    NASA Astrophysics Data System (ADS)

    Orama, Lionel R.

    In this work the interaction between series connected gas and vacuum circuit breaker arcs has been studied. The breakdown phenomena in vacuum interrupters during the post arc current period have been of special interest. Numerical models of gas and vacuum arcs were developed in the form of black box models. Especially, the vacuum post arc model was implemented by combining the existing transition model with an ion density function and expressions for the breakdown mechanisms. The test series studied reflect that for electric fields on the order of 10sp7V/m over the anode, the breakdown of the vacuum gap can result from a combination of both thermal and electrical stresses. For a particular vacuum device, the vacuum model helps to find the interruption limits of the electric field and power density over the anode. The series connection of gas and vacuum interrupters always performs better than the single gas device. Moreover, to take advantage of the good characteristics of both devices, the time between the current zero crossing in each interrupter can be changed. This current zero synchronization is controlled by changing the capacitance in parallel to the gas device. This gas/vacuum interrupter is suitable for interruption of very stressful short circuits in which the product of the dI/dt before current zero and the dV/dt after current zero is very high. Also, a single SF6 interrupter can be replaced by an air circuit breaker of the same voltage rating in series with a vacuum device without compromising the good performance of the SF6 device. Conceptually, a series connected vacuum device can be used for high voltage applications with equal distribution of electrical stresses between the individual interrupters. The equalization can be made by a sequential opening of the individual contact pairs, beginning with the interruptors that are closer to ground potential. This could eliminate the use of grading capacitors.

  3. Vacuum generation in pneumatic artificial heart drives with a specially designed ejector system.

    PubMed

    Schima, H; Huber, L; Spitaler, F

    1990-06-01

    To improve the filling characteristics of pneumatically driven membrane artificial hearts (AHs), a vacuum is applied during diastole. This paper describes an ejector system for AH-drivers based on the Venturi effect, which was designed for this purpose. It provides vacuums of more than -40 mmHg at flow rates up to 50 l/min requiring a supplying primary gas pressure of less than 150 kPa (1140 mmHg). Under normal working conditions, the necessary supply flow was less than 5l/min. The device is small, cheap, quiet and fail-safe, and has been evaluated successfully in experimental and clinical use.

  4. The mythology of anticoagulation therapy interruption for dental surgery.

    PubMed

    Wahl, Michael J

    2018-01-01

    Continuous anticoagulation therapy is used to prevent heart attacks, strokes, and other embolic complications. When patients receiving anticoagulation therapy undergo dental surgery, a decision must be made about whether to continue anticoagulation therapy and risk bleeding complications or briefly interrupt anticoagulation therapy and increase the risk of developing embolic complications. Results from decades of studies of thousands of dental patients receiving anticoagulation therapy reveal that bleeding complications requiring more than local measures for hemostasis have been rare and never fatal. However, embolic complications (some of which were fatal and others possibly permanently debilitating) sometimes have occurred in patients whose anticoagulation therapy was interrupted for dental procedures. Although there is now virtually universal consensus among national medical and dental groups and other experts that anticoagulation therapy should not be interrupted for most dental surgery, there are still some arguments made supporting anticoagulation therapy interruption. An analysis of these arguments shows them to be based on a collection of myths and half-truths rather than on logical scientific conclusions. The time has come to stop anticoagulation therapy interruption for dental procedures. Copyright © 2018 American Dental Association. Published by Elsevier Inc. All rights reserved.

  5. The incidence of wound complications related to negative pressure wound therapy power outage and interruption of treatment in orthopaedic trauma patients.

    PubMed

    Collinge, Cory; Reddix, Robert

    2011-02-01

    Negative pressure wound therapy (NPWT) using the Vacuum Assisted Closure system is an invaluable tool for use on patients with complex limb and soft tissue problems. Recently, the manufacturer (Kinetic Concepts, Inc, San Antonio, TX) made significant modifications to the NPWT platform, including computer software, battery, alarming systems, electric cord and plug apparatus, and others. Since these modifications, we have seen several cases in which the NPWT device has powered off resulting in an unrecognized interruption of therapy. We sought to evaluate the conditions and clinical effects, if any, to orthopaedic trauma patients who experienced an interruption of NPWT therapy when the device powers off. Retrospective study of consecutive patients. Two neighboring regional trauma centers. One hundred twenty-three consecutive orthopaedic trauma patients treated with NPWT by two orthopaedic trauma surgeons between May and November 2008. Patient/injury, treatment, and perioperative clinical outcomes data (with emphasis on wound complications such as infection, graft loss, and unscheduled surgery) were collected from medical records and wound care databases. Twelve patients (10%) had problems with the NPWT device powering off causing an unrecognized interruption of therapy. Eleven patients underwent early (less than 6 hours) wound débridement and reapplication of NPWT after detection, of which nine required unplanned surgery. Seven of the 12 patients recognized as having failed NPWT of this type ultimately experienced wound complications, including five deep infections and both patients being treated with an Integra graft (loss of graft). We have seen substantial problems in orthopaedic trauma patients treated with the NPWT, in which the device has powered off resulting in an unrecognized interruption of therapy. This has resulted in atypically unhealthy-appearing wounds, unplanned surgeries for débridement, and most importantly, an increased incidence of wound

  6. Apparatus for generating quasi-free-space microwave-driven plasmas

    NASA Astrophysics Data System (ADS)

    Hoff, Brad W.; French, David M.; Reid, Remington R.; Lawrance, Julie E.; Lepell, P. David; Maestas, Sabrina S.

    2016-03-01

    An apparatus for generating quasi-free-space microwave-driven plasmas has been designed, constructed, and tested. The plasma is driven by a multi-kW, ˜5 GHz microwave beam focused at the center of a vacuum chamber using a Koch-type metal plate lens. Sustained plasma discharges have been generated in argon at pressures ranging from 150 to 200 mTorr, at beam power levels ranging from 5 to 10 kW, and at gas flow rates of approximately 200 SCCM.

  7. Apparatus for generating quasi-free-space microwave-driven plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoff, Brad W.; French, David M.; Reid, Remington R.

    An apparatus for generating quasi-free-space microwave-driven plasmas has been designed, constructed, and tested. The plasma is driven by a multi-kW, ∼5 GHz microwave beam focused at the center of a vacuum chamber using a Koch-type metal plate lens. Sustained plasma discharges have been generated in argon at pressures ranging from 150 to 200 mTorr, at beam power levels ranging from 5 to 10 kW, and at gas flow rates of approximately 200 SCCM.

  8. Apparatus for generating quasi-free-space microwave-driven plasmas.

    PubMed

    Hoff, Brad W; French, David M; Reid, Remington R; Lawrance, Julie E; Lepell, P David; Maestas, Sabrina S

    2016-03-01

    An apparatus for generating quasi-free-space microwave-driven plasmas has been designed, constructed, and tested. The plasma is driven by a multi-kW, ∼5 GHz microwave beam focused at the center of a vacuum chamber using a Koch-type metal plate lens. Sustained plasma discharges have been generated in argon at pressures ranging from 150 to 200 mTorr, at beam power levels ranging from 5 to 10 kW, and at gas flow rates of approximately 200 SCCM.

  9. Weak stability of the plasma-vacuum interface problem

    NASA Astrophysics Data System (ADS)

    Catania, Davide; D'Abbicco, Marcello; Secchi, Paolo

    2016-09-01

    We consider the free boundary problem for the two-dimensional plasma-vacuum interface in ideal compressible magnetohydrodynamics (MHD). In the plasma region, the flow is governed by the usual compressible MHD equations, while in the vacuum region we consider the Maxwell system for the electric and the magnetic fields. At the free interface, driven by the plasma velocity, the total pressure is continuous and the magnetic field on both sides is tangent to the boundary. We study the linear stability of rectilinear plasma-vacuum interfaces by computing the Kreiss-Lopatinskiĭ determinant of an associated linearized boundary value problem. Apart from possible resonances, we obtain that the piecewise constant plasma-vacuum interfaces are always weakly linearly stable, independently of the size of tangential velocity, magnetic and electric fields on both sides of the characteristic discontinuity. We also prove that solutions to the linearized problem obey an energy estimate with a loss of regularity with respect to the source terms, both in the interior domain and on the boundary, due to the failure of the uniform Kreiss-Lopatinskiĭ condition, as the Kreiss-Lopatinskiĭ determinant associated with this linearized boundary value problem has roots on the boundary of the frequency space. In the proof of the a priori estimates, a crucial part is played by the construction of symmetrizers for a reduced differential system, which has poles at which the Kreiss-Lopatinskiĭ condition may fail simultaneously.

  10. [Structured treatment interruption in HIV-infected adolescents].

    PubMed

    Vidal, P; Lalande, M; Rodiere, M

    2009-07-01

    Structured treatment interruption in HIV is now being debated. There are 2 cases in which it may be discussed: when the initial treatment was started early and when there is no compliance to treatment [Yeni P, et al. Les nouvelles recommandations de prise en charge des personnes infectées par le VIH 2006. Paris: Flammarion médecine-sciences; 2006]. Noncompliant behavior is one of the characteristics of chronic illness during adolescence. In HIV infection, however, the prognosis is negatively influenced because the resulting resistance to the antiretroviral therapy can further reduce therapeutic options. Therefore, it is important in such a critical period to consider both what is consciously and unconsciously at stake and what responsible action could be taken when a specialist is faced with spontaneous (unplanned) treatment interruption. We report here examples of follow-up care, interruption, and resumption of treatment in 4 female adolescents.

  11. The culture contributing to interruptions in the nursing work environment: An ethnography.

    PubMed

    Hopkinson, Susan G; Wiegand, Debra L

    2017-12-01

    To understand the occurrence of interruptions within the culture of the medical nursing unit work environment. Interruptions may lead to errors in nursing work. Little is known about how the culture of the nursing work environment contributes to interruptions. A micro-focused ethnographic study was conducted. Data collection involved extensive observation of a nursing unit, 1:1 observations of nurses and follow-up interviews with the nurses. Data were analysed from unstructured field notes and interview transcripts. The definitions of interruption and culture guided coding, categorising and identification of themes. A framework was developed that describes the medical nursing unit as a complex culture full of unpredictable, nonlinear changes that affect the entire interconnected system, often in the form of an interruption. The cultural elements contributing to interruptions included (i) the value placed on excellence in patient care and meeting personal needs, (ii) the beliefs that the nurses had to do everything by themselves and that every phone call was important, (iii) the patterns of changing patients, patient transport and coordination of resources and (iv) the normative practices of communicating and adapting. Interruptions are an integral part of the culture of a medical nursing unit. Uniformly decreasing interruptions may disrupt current practices, such as communication to coordinate care, that are central to nursing work. In future research, the nursing work environment must be looked at through the lens of a complex system. Interventions to minimise the negative impact of interruptions must take into account the culture of the nursing as a complex adaptive system. Nurses should be educated on their own contribution to interruptions and issues addressed at a system level, rather than isolating the interruption as the central issue. © 2017 John Wiley & Sons Ltd.

  12. Suicide Risk Characteristics among Aborted, Interrupted, and Actual Suicide Attempters

    PubMed Central

    Burke, Taylor A.; Hamilton, Jessica L.; Ammerman, Brooke A.; Stange, Jonathan P.; Alloy, Lauren B.

    2017-01-01

    Few studies have investigated suicide risk characteristics associated with interrupted and aborted suicide attempts. The present study aimed to empirically examine whether assessing a history of interrupted and aborted suicide attempts is valuable when assessing suicide risk, given the relative lack of literature in this area to date. To inform this question, the current study examined differences in risk factors for suicidal behavior among individuals who have carried out a suicide attempt, individuals who report having a history of only interrupted and/or aborted suicide attempts, and non-attempter controls. Approximately 447 undergraduates (M = 21.10 years; SD = 4.16; 77.6% female) completed measures of carried out suicide attempts, interrupted suicide attempts, aborted suicide attempts, acquired capability for suicide, suicide likelihood, depressive symptoms, suicidal ideation, and non-suicidal self-injury. Results suggest that a faction of individuals endorse interrupted and/or aborted suicide attempts (8.7%), but do not endorse carried out suicide attempts, even in non-clinical samples. Furthermore, results suggest that there are few clinically meaningful differences between those with a history of carried out suicide attempts and interrupted/aborted suicide attempts, suggesting that individuals with a history of these lesser studied suicidal behaviors are an important group to target for suicide risk intervention. PMID:27344029

  13. 43 CFR 3481.4 - Temporary interruption in coal severance.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 43 Public Lands: Interior 2 2013-10-01 2013-10-01 false Temporary interruption in coal severance... LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) COAL EXPLORATION AND MINING OPERATIONS RULES General Provisions § 3481.4 Temporary interruption in coal severance. ...

  14. 43 CFR 3481.4 - Temporary interruption in coal severance.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 43 Public Lands: Interior 2 2012-10-01 2012-10-01 false Temporary interruption in coal severance... LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) COAL EXPLORATION AND MINING OPERATIONS RULES General Provisions § 3481.4 Temporary interruption in coal severance. ...

  15. 43 CFR 3481.4 - Temporary interruption in coal severance.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 43 Public Lands: Interior 2 2014-10-01 2014-10-01 false Temporary interruption in coal severance... LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) COAL EXPLORATION AND MINING OPERATIONS RULES General Provisions § 3481.4 Temporary interruption in coal severance. ...

  16. 43 CFR 3481.4 - Temporary interruption in coal severance.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 43 Public Lands: Interior 2 2011-10-01 2011-10-01 false Temporary interruption in coal severance... LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) COAL EXPLORATION AND MINING OPERATIONS RULES General Provisions § 3481.4 Temporary interruption in coal severance. ...

  17. Vacuum mechatronics

    NASA Technical Reports Server (NTRS)

    Hackwood, Susan; Belinski, Steven E.; Beni, Gerardo

    1989-01-01

    The discipline of vacuum mechatronics is defined as the design and development of vacuum-compatible computer-controlled mechanisms for manipulating, sensing and testing in a vacuum environment. The importance of vacuum mechatronics is growing with an increased application of vacuum in space studies and in manufacturing for material processing, medicine, microelectronics, emission studies, lyophylisation, freeze drying and packaging. The quickly developing field of vacuum mechatronics will also be the driving force for the realization of an advanced era of totally enclosed clean manufacturing cells. High technology manufacturing has increasingly demanding requirements for precision manipulation, in situ process monitoring and contamination-free environments. To remove the contamination problems associated with human workers, the tendency in many manufacturing processes is to move towards total automation. This will become a requirement in the near future for e.g., microelectronics manufacturing. Automation in ultra-clean manufacturing environments is evolving into the concept of self-contained and fully enclosed manufacturing. A Self Contained Automated Robotic Factory (SCARF) is being developed as a flexible research facility for totally enclosed manufacturing. The construction and successful operation of a SCARF will provide a novel, flexible, self-contained, clean, vacuum manufacturing environment. SCARF also requires very high reliability and intelligent control. The trends in vacuum mechatronics and some of the key research issues are reviewed.

  18. Individual Differences in Working-Memory Capacity and Task Resumption Following Interruptions

    ERIC Educational Resources Information Center

    Foroughi, Cyrus K.; Werner, Nicole E.; McKendrick, Ryan; Cades, David M.; Boehm-Davis, Deborah A.

    2016-01-01

    Previous research has shown that there is a time cost (i.e., a resumption lag) associated with resuming a task following an interruption and that the longer the duration of the interruption, the greater the time cost (i.e., resumption lag increases as interruption duration increases). The memory-for-goals model (Altmann & Trafton, 2002)…

  19. Thrombus formation in the interrupted segment of the aorta.

    PubMed

    Karavelioğlu, Yusuf; Kalçık, Macit; Yetim, Mucahit; Doğan, Tolga; Gölbaşı, Zehra

    2017-06-01

    Interrupted aorta is a very rare heart defect in which there is a gap between the ascending and the descending thoracic aorta. It is usually associated with other cardiac anomalies, including ventricular septal defect, ductus arteriosus, and truncus arteriosus. Severe cases present with serious complications such as hypertension, heart failure, or intracranial hemorrhage. Neurological complications are very rare form of presentation and commonly associated with intracranial aneurysms. We have reported a case of interrupted aorta who presented with transient ischemic attack due to thrombus formation in the interrupted segment of the aorta. © 2017, Wiley Periodicals, Inc.

  20. Photodiode-based cutting interruption sensor for near-infrared lasers.

    PubMed

    Adelmann, B; Schleier, M; Neumeier, B; Hellmann, R

    2016-03-01

    We report on a photodiode-based sensor system to detect cutting interruptions during laser cutting with a fiber laser. An InGaAs diode records the thermal radiation from the process zone with a ring mirror and optical filter arrangement mounted between a collimation unit and a cutting head. The photodiode current is digitalized with a sample rate of 20 kHz and filtered with a Chebyshev Type I filter. From the measured signal during the piercing, a threshold value is calculated. When the diode signal exceeds this threshold during cutting, a cutting interruption is indicated. This method is applied to sensor signals from cutting mild steel, stainless steel, and aluminum, as well as different material thicknesses and also laser flame cutting, showing the possibility to detect cutting interruptions in a broad variety of applications. In a series of 83 incomplete cuts, every cutting interruption is successfully detected (alpha error of 0%), while no cutting interruption is reported in 266 complete cuts (beta error of 0%). With this remarkable high detection rate and low error rate, the possibility to work with different materials and thicknesses in combination with the easy mounting of the sensor unit also to existing cutting machines highlight the enormous potential for this sensor system in industrial applications.

  1. Miscarriage: A Dream Interrupted

    ERIC Educational Resources Information Center

    Trepal, Heather C.; Semivan, Suzanne Gibson; Caley-Bruce, Mary

    2005-01-01

    Pregnancy is a developmental task that requires women to become accustomed to inherent and sometimes profound biological, somatic, and psychological changes. When pregnancy is interrupted by miscarriage, it may become a pivotal crisis point in the development of a woman's maternal identity as well as an issue in family development. This manuscript…

  2. Deconstruction as Narrative Interruption

    ERIC Educational Resources Information Center

    Gilbert-Walsh, James

    2007-01-01

    Because of the way it prioritizes "interruption" and calls into question the very possibility of producing coherent, self-contained narratives, the deconstructive work of Jacques Derrida is often thought to be intrinsically anti-narrative in its very structure; and yet there are those who insist that, to the contrary, deconstruction is a narrative…

  3. 14 CFR 91.1417 - CAMP: Mechanical interruption summary report.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false CAMP: Mechanical interruption summary... Ownership Operations Program Management § 91.1417 CAMP: Mechanical interruption summary report. Each program... route, caused by known or suspected mechanical difficulties or malfunctions that are not required to be...

  4. Natural vacuum electronics

    NASA Technical Reports Server (NTRS)

    Leggett, Nickolaus

    1990-01-01

    The ambient natural vacuum of space is proposed as a basis for electron valves. Each valve is an electron controlling structure similiar to a vacuum tube that is operated without a vacuum sustaining envelope. The natural vacuum electron valves discussed offer a viable substitute for solid state devices. The natural vacuum valve is highly resistant to ionizing radiation, system generated electromagnetic pulse, current transients, and direct exposure to space conditions.

  5. Characteristics of Interruptions During Medication Administration:An Integrative Review of Direct Observational Studies.

    PubMed

    Schroers, Ginger

    2018-06-26

    The purpose of this review was to synthesize and summarize data gathered by direct observation of the characteristics of interruptions in the context of nursing medication administration in hospital settings. Interruptions are prevalent during the medication administration process performed by nurses in hospital settings and have been found to be associated with an increase in frequency and severity of nursing medication administration errors. In addition, interruptions decrease task efficiency, leading to longer medication administration completion times. Integrative review. The electronic databases Cumulative Index of Nursing and Allied Health Literature (CINAHL), PubMED, PsyARTICLES, and Google Scholar were searched using the terms "interruptions" AND "medication administration" AND "direct observation". Nine articles met the inclusion criteria. Interruptions are likely to occur at least once during nursing medication administration processes in hospital settings. This finding applies to medication administered to one patient, termed a medication pass, and medication administered to multiple patients, termed a mediation round. Interruptions are most commonly caused by another nurse, staff member, or are self-initiated, and last approximately one minute in length. A raised awareness among staff of the most common sources of interruptions may encourage changes that lead to a decrease in the occurrence of interruptions. In addition, nurse leaders can apply an understanding of the common characteristics of interruptions to guide research, policies, and educational methods aimed at interruption management strategies. The findings from this review can be used to guide the identification and development of targeted interventions and strategies that would have the most substantial impact to reduce and manage interruptions during medication administration. Interruption management strategies have the potential to lead to a decrease in medication errors and an increase in

  6. The Interrupted Intercourse in the Election Communication: Pragmatic Aspect

    ERIC Educational Resources Information Center

    Andryuchshenko, Olga K.; Suyunova, Gulnara S.; Nygmetova, Bibigul Dz.; Garanina, Ekaterina P.

    2016-01-01

    The article provides analysis of the interrupted communication as part of the communication in the election discourse. The authors explored the most typical reasons for the interrupted communication in the electoral discourse analyzed communication failures as a kind of ineffective communication. Communication failures are presented as a result of…

  7. Application Study of a High Temperature Superconducting Fault Current Limiter for Electric Power System

    NASA Astrophysics Data System (ADS)

    Naito, Yuji; Shimizu, Iwao; Yamaguchi, Iwao; Kaiho, Katsuyuki; Yanabu, Satoru

    Using high temperature superconductor, a Superconducting Fault Current Limiter (SFCL) was made and tested. Superconductor and vacuum interrupter as commutation switch are connected in parallel with bypass coil. When a fault occurs and the excessive current flows, superconductor is first quenched and the current is transferred to bypass coil because on voltage drop of superconductor. At the same time, since magnetic field is generated by current which flows in bypass coil, commutation switch is immediately driven by electromagnetic repulsion plate connected to driving rod of vacuum interrupter, and superconductor is separated from this circuit. Using the testing model, we could separate the superconductor from a circuit due to movement of vacuum interrupter within half-cycle current and transfer all current to bypass coil. Since operation of a commutation switch is included in current limiting operation of this testing model, it is one of helpful circuit of development of SFCL in the future. Moreover, since it can make the consumed energy of superconductor small during fault state due to realization of high-speed switch with simple composition, the burden of superconductor is reduced compared with conventional resistive type SFCL and it is considered that the flexibility of a SFCL design increases. Cooperation with a circuit breaker was also considered, the trial calculation of a parameter and energy of operation is conducted and discussion in the case of installing the SFCL to electric power system is made.

  8. Simulation-Based Testing of Pager Interruptions During Laparoscopic Cholecystectomy.

    PubMed

    Sujka, Joseph A; Safcsak, Karen; Bhullar, Indermeet S; Havron, William S

    2018-01-30

    To determine if pager interruptions affect operative time, safety, or complications and management of pager issues during a simulated laparoscopic cholecystectomy. Twelve surgery resident volunteers were tested on a Simbionix Lap Mentor II simulator. Each resident performed 6 randomized simulated laparoscopic cholecystectomies; 3 with pager interruptions (INT) and 3 without pager interruptions (NO-INT). The pager interruptions were sent in the form of standardized patient vignettes and timed to distract the resident during dissection of the critical view of safety and clipping of the cystic duct. The residents were graded on a pass/fail scale for eliciting appropriate patient history and management of the pager issue. Data was extracted from the simulator for the following endpoints: operative time, safety metrics, and incidence of operative complications. The Mann-Whitney U test and contingency table analysis were used to compare the 2 groups (INT vs. NO-INT). Level I trauma center; Simulation laboratory. Twelve general surgery residents. There was no significant difference between the 2 groups in any of the operative endpoints as measured by the simulator. However, in the INT group, only 25% of the time did the surgery residents both adequately address the issue and provide effective patient management in response to the pager interruption. Pager interruptions did not affect operative time, safety, or complications during the simulated procedure. However, there were significant failures in the appropriate evaluations and management of pager issues. Consideration for diversion of patient care issues to fellow residents not operating to improve quality and safety of patient care outside the operating room requires further study. Copyright © 2018. Published by Elsevier Inc.

  9. VACUUM TRAP

    DOEpatents

    Gordon, H.S.

    1959-09-15

    An improved adsorption vacuum trap for use in vacuum systems was designed. The distinguishing feature is the placement of a plurality of torsionally deformed metallic fins within a vacuum jacket extending from the walls to the central axis so that substantially all gas molecules pass through the jacket will impinge upon the fin surfaces. T fins are heated by direct metallic conduction, thereby ol taining a uniform temperature at the adeorbing surfaces so that essentially all of the condensible impurities from the evacuating gas are removed from the vacuum system.

  10. Active hold-down for heat treating

    NASA Technical Reports Server (NTRS)

    Collins, E. R., Jr. (Inventor)

    1986-01-01

    The object of the disclosure is to provide a vacuum hold-down for holding thin sheets to a support surface, which permits the thin sheet to change dimensions as it is held down. The hold-down includes numerous holes in the support surface, through which a vacuum is applied from a vacuum source. The holes are arranged in zones. The vacuum is repeatedly interrupted at only one or a few zones, while it continues to be applied to other zones, to allow the workpiece to creep along that interrupted zone. The vacuum to different zones is interrupted at different times, as by a slowly turning valve number, to allow each zone of the workpiece to creep. A positive pressure may be applied from a pressured air source to a zone when the vacuum is interrupted there, to help lift the corresponding workpiece zone off the surface to aid in creeping. The workpiece may undergo dimensional changes because of heating, cooling, drying, or other procedure.

  11. Dealing with task interruptions in complex dynamic environments: are two heads better than one?

    PubMed

    Tremblay, Sébastien; Vachon, François; Lafond, Daniel; Kramer, Chelsea

    2012-02-01

    This study examined whether teaming up mitigates individual vulnerability to task interruptions in complex dynamic situations. Omnipresent in everyday multitasking environments, task interruptions are usually detrimental to individual performance. This is particularly crucial in dynamic command and control (C2) safety-critical contexts because of the additional challenge imposed by the continually evolving situation during the interruption. We employed a firefighting microworld to simulate C2 in the context of supervisory control to examine the relative impact of interruptions on participants working in a functional dyad versus operators working alone. Although task interruption was detrimental to participants' efficacy of monitoring resources, the negative impact of interruption was reduced for those working in teams. Teaming up translated into faster resumption time, but only if both teammates were interrupted simultaneously. Interrupting only one team member was associated with increased postinterruption communications and slower resumption time. These findings suggest that in complex dynamic situations working in a small team confers more resistance to task interruption than working alone by virtue of the reduced individual workload typical of teamwork. The benefit of collaborative work seems nevertheless mediated by the coordination and communication overhead associated with teamwork. The present findings have practical implications for operators dealing with unexpected events such as task interruptions in C2 environments.

  12. Causal role for the subthalamic nucleus in interrupting behavior

    PubMed Central

    Fife, Kathryn H; Gutierrez-Reed, Navarre A; Zell, Vivien; Bailly, Julie; Lewis, Christina M; Aron, Adam R; Hnasko, Thomas S

    2017-01-01

    Stopping or pausing in response to threats, conflicting information, or surprise is fundamental to behavior. Evidence across species has shown that the subthalamic nucleus (STN) is activated by scenarios involving stopping or pausing, yet evidence that the STN causally implements stops or pauses is lacking. Here we used optogenetics to activate or inhibit mouse STN to test its putative causal role. We first demonstrated that optogenetic stimulation of the STN excited its major projection targets. Next we showed that brief activation of STN projection neurons was sufficient to interrupt or pause a self-initiated bout of licking. Finally, we developed an assay in which surprise was used to interrupt licking, and showed that STN inhibition reduced the disruptive effect of surprise. Thus STN activation interrupts behavior, and blocking the STN blunts the interruptive effect of surprise. These results provide strong evidence that the STN is both necessary and sufficient for such forms of behavioral response suppression. DOI: http://dx.doi.org/10.7554/eLife.27689.001 PMID:28742497

  13. Predictability of Interruptions During Medication Administration With Related Behavioral Management Strategies.

    PubMed

    Johnson, Maree; Weidemann, Gabrielle; Adams, Rebecca; Manias, Elizabeth; Levett-Jones, Tracy; Aguilar, Vicki; Everett, Bronwyn

    The aim of this qualitative study was to examine the nature of interruptions during medication administration. Focus groups were conducted with medical/surgical nurses (n = 15), critical care nurses (n = 13), and nurse managers/educators/specialists (n = 6). Most interruptions (78%) were predictable. Nurse-adopted strategies included blocking, engaging, mediating, multitasking, and preventing. Educational content was developed that relates behavioral strategies to respond to predictable and unpredictable interruptions.

  14. A systematic review of the psychological literature on interruption and its patient safety implications.

    PubMed

    Li, Simon Y W; Magrabi, Farah; Coiera, Enrico

    2012-01-01

    To understand the complex effects of interruption in healthcare. As interruptions have been well studied in other domains, the authors undertook a systematic review of experimental studies in psychology and human-computer interaction to identify the task types and variables influencing interruption effects. 63 studies were identified from 812 articles retrieved by systematic searches. On the basis of interruption profiles for generic tasks, it was found that clinical tasks can be distinguished into three broad types: procedural, problem-solving, and decision-making. Twelve experimental variables that influence interruption effects were identified. Of these, six are the most important, based on the number of studies and because of their centrality to interruption effects, including working memory load, interruption position, similarity, modality, handling strategies, and practice effect. The variables are explained by three main theoretical frameworks: the activation-based goal memory model, prospective memory, and multiple resource theory. This review provides a useful starting point for a more comprehensive examination of interruptions potentially leading to an improved understanding about the impact of this phenomenon on patient safety and task efficiency. The authors provide some recommendations to counter interruption effects. The effects of interruption are the outcome of a complex set of variables and should not be considered as uniformly predictable or bad. The task types, variables, and theories should help us better to identify which clinical tasks and contexts are most susceptible and assist in the design of information systems and processes that are resilient to interruption.

  15. Comparison of vacuum and non-vacuum urine tubes for urinary sediment analysis.

    PubMed

    Topcuoglu, Canan; Sezer, Sevilay; Kosem, Arzu; Ercan, Mujgan; Turhan, Turan

    2017-12-01

    Urine collection systems with aspiration system for vacuum tubes are becoming increasingly common for urinalysis, especially for microscopic examination of the urine. In this study, we aimed to examine whether vacuum aspiration of the urine sample has any adverse effect on sediment analysis by comparing results from vacuum and non-vacuum urine tubes. The study included totally 213 urine samples obtained from inpatients and outpatients in our hospital. Urine samples were collected to containers with aspiration system for vacuum tubes. Each sample was aliquoted to both vacuum and non-vacuum urine tubes. Urinary sediment analysis was performed using manual microscope. Results were evaluated using chi-square test. Comparison of the sediment analysis results from vacuum and non-vacuum urine tubes showed that results were highly concordant for erythrocyte, leukocyte and epithelial cells (gamma values 1, 0.997, and 0.994, respectively; p < .001). Results were also concordant for urinary casts, crystals and yeast (kappa values 0.815, 0.945 and 1, respectively; p < .001). The results show that in urinary sediment analysis, vacuum aspiration has no adverse effect on the cellular components except on casts.

  16. Career Interruptions and Subsequent Earnings: A Reexamination Using Swedish Data.

    ERIC Educational Resources Information Center

    Albrecht, James W.; Edin, Per-Anders; Sundstrom, Marianne; Vroman, Susan B.

    1999-01-01

    Cross-sectional and panel estimations of Swedish data reveal that different types of career interruptions have different effects on wages, varying by gender. Therefore, human capital depreciation does not entirely account for the negative effect of career interruptions on subsequent wages. (SK)

  17. Situation Awareness and Interruption Handling During Medication Administration.

    PubMed

    Sitterding, Mary Cathryn; Ebright, Patricia; Broome, Marion; Patterson, Emily S; Wuchner, Staci

    2014-08-01

    Medication administration error remains a leading cause of preventable death. A gap exists in understanding attentional dynamics, such as nurse situation awareness (SA) while managing interruptions during medication administration. The aim was to describe SA during medication administration and interruption handling strategies. A cross-sectional, descriptive design was used. Cognitive task analysis (CTA) methods informed analysis of 230 interruptions. Themes were analyzed by SA level. The nature of the stimuli noticed emerged as a Level 1 theme, in contrast to themes of uncertainty, relevance, and expectations (Level 2 themes). Projected or anticipated interventions (Level 3 themes) reflected workload balance between team and patient foregrounds. The prevalence of cognitive time-sharing during the medication administration process was remarkable. Findings substantiated the importance of the concept of SA within nursing as well as the contribution of CTA in understanding the cognitive work of nursing during medication administration. © The Author(s) 2014.

  18. Two-dimensional electron density characterisation of arc interruption phenomenon in current-zero phase

    NASA Astrophysics Data System (ADS)

    Inada, Yuki; Kamiya, Tomoki; Matsuoka, Shigeyasu; Kumada, Akiko; Ikeda, Hisatoshi; Hidaka, Kunihiko

    2018-01-01

    Two-dimensional electron density imaging over free burning SF6 arcs and SF6 gas-blast arcs was conducted at current zero using highly sensitive Shack-Hartmann type laser wavefront sensors in order to experimentally characterise electron density distributions for the success and failure of arc interruption in the thermal reignition phase. The experimental results under an interruption probability of 50% showed that free burning SF6 arcs with axially asymmetric electron density profiles were interrupted with a success rate of 88%. On the other hand, the current interruption of SF6 gas-blast arcs was reproducibly achieved under locally reduced electron densities and the interruption success rate was 100%.

  19. 49 CFR 570.56 - Vacuum brake assist unit and vacuum brake system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... The following requirements apply to vehicles with vacuum brake assist units and vacuum brake systems. (a) Vacuum brake assist unit integrity. The vacuum brake assist unit shall demonstrate integrity as... maintained on the pedal. (1) Inspection procedure. Stop the engine and apply service brake several times to...

  20. Demonstrations with a Vacuum: Old Demonstrations for New Vacuum Pumps.

    ERIC Educational Resources Information Center

    Greenslade, Thomas B., Jr.

    1989-01-01

    Explains mechanisms of 19th-century vacuum pumps. Describes demonstrations using the pump including guinea and feather tube, aurora tube, electric egg, Gassiots cascade, air mill, bell in vacuum, density and buoyancy of air, fountain in vacuum, mercury shower, palm and bladder glasses, Bacchus demonstration, pneumatic man-lifter, and Magdeburg…

  1. Workflow interruptions, cognitive failure and near-accidents in health care.

    PubMed

    Elfering, Achim; Grebner, Simone; Ebener, Corinne

    2015-01-01

    Errors are frequent in health care. A specific model was tested that affirms failure in cognitive action regulation to mediate the influence of nurses' workflow interruptions and safety conscientiousness on near-accidents in health care. One hundred and sixty-five nurses from seven Swiss hospitals participated in a questionnaire survey. Structural equation modelling confirmed the hypothesised mediation model. Cognitive failure in action regulation significantly mediated the influence of workflow interruptions on near-accidents (p < .05). An indirect path from conscientiousness to near-accidents via cognitive failure in action regulation was also significant (p < .05). Compliance with safety regulations was significantly related to cognitive failure and near-accidents; moreover, cognitive failure mediated the association between compliance and near-accidents (p < .05). Contrary to expectations, compliance with safety regulations was not related to workflow interruptions. Workflow interruptions caused by colleagues, patients and organisational constraints are likely to trigger errors in nursing. Work redesign is recommended to reduce cognitive failure and improve safety of nurses and patients.

  2. Technology-mediated awareness: facilitating the handling of (un)wanted interruptions in a hospital setting.

    PubMed

    Klemets, Joakim; Evjemo, Tor Erik

    2014-09-01

    Nurses' work in hospital departments is highly collaborative and includes communication with a variety of actors. To further support nurses' communications, wireless phones, on which nurses receive both nurse calls and ordinary phone calls, have been introduced. However, while they ensure high availability among the mobile nurses, these phones also contribute to an increased number of interruptions. This paper aims to discover whether all interruptions caused by the wireless phones are unwanted. Further, it investigates how nurses handle these interruptions in a hospital setting in order to construct a foundation for guidelines to use in designing these types of systems. Qualitative and ethnographically inspired fieldwork, including workshops with both ordinary and student nurses from a Norwegian hospital, was undertaken. Patients from two hospital departments were interviewed. Nurses struggle to handle interruptions caused by the wireless nurse call system. Deciding whether to abort an activity or not to respond to an interruption is regarded as stressful. The decision is further complicated by the complex nature of the interruptions. At the same time, patients anticipate that nurses are able to make these judgements with limited information. Nurses' work is highly collaborative, and nurses depend on one another to carry out their work and manage interruptions. The dual nature of the interruptions is complex, and whether an interruption is wanted or unwanted depends on many factors. Nurses manage interruptions mainly by making their own activities visible and monitoring colleagues' work. Therefore, nurses' awareness of colleagues' activities is a key factor in how they handle interruptions in the form of nurse calls. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  3. Characterization of railroad bridge service interruptions.

    DOT National Transportation Integrated Search

    2013-02-01

    The Federal Railroad Administration contracted Transportation Technology Center, Inc., to study bridge problems that cause accidents or service interruptions and to use this information to evaluate the need to develop bridge monitoring systems. Exist...

  4. Improved Vacuum Bazooka

    NASA Astrophysics Data System (ADS)

    Cockman, John

    2003-04-01

    This apparatus is a modification to the well-known "vacuum bazooka" (PIRA 2B30.70). My vacuum bazooka is easy to construct and demonstrate, requires no precise fittings, foil, or vacuum grease, and propels ping-pong balls at a tremendous velocity!

  5. The Chronic Detrimental Impact of Interruptions in a Simulated Submarine Track Management Task.

    PubMed

    Loft, Shayne; Sadler, Andreas; Braithwaite, Janelle; Huf, Samuel

    2015-12-01

    The objective of this article is to examine the extent to which interruptions negatively impact situation awareness and long-term performance in a submarine track management task where pre- and postinterruption display scenes remained essentially identical. Interruptions in command and control task environments can degrade performance well beyond the first postinterruption action typically measured for sequential static tasks, because individuals need to recover their situation awareness for multiple unfolding display events. Participants in the current study returned to an unchanged display scene following interruption and therefore could be more immune to such long-term performance deficits. The task required participants to monitor a display to detect contact heading changes and to make enemy engagement decisions. Situation awareness (Situation Present Assessment Method) and subjective workload (NASA-Task Load Index) were measured. The interruption replaced the display for 20 s with a blank screen, during which participants completed a classification task. Situation awareness after returning from interruption was degraded. Participants were slower to make correct engagement decisions and slower and less accurate in detecting heading changes, despite these task decisions being made at least 40 s following the interruption. Interruptions negatively impacted situation awareness and long-term performance because participants needed to redetermine the location and spatial relationship between the displayed contacts when returning from interruption, either because their situation awareness for the preinterruption scene decayed or because they did not encode the preinterruption scene. Interruption in work contexts such as submarines is unavoidable, and further understanding of how operators are affected is required to improve work design and training. © 2015, Human Factors and Ergonomics Society.

  6. Improving memory after interruption: exploiting soft constraints and manipulating information access cost.

    PubMed

    Morgan, Phillip L; Patrick, John; Waldron, Samuel M; King, Sophia L; Patrick, Tanya

    2009-12-01

    Forgetting what one was doing prior to interruption is an everyday problem. The recent soft constraints hypothesis (Gray, Sims, Fu, & Schoelles, 2006) emphasizes the strategic adaptation of information processing strategy to the task environment. It predicts that increasing information access cost (IAC: the time, and physical and mental effort involved in accessing information) encourages a more memory-intensive strategy. Like interruptions, access costs are also intrinsic to most work environments, such as when opening documents and e-mails. Three experiments investigated whether increasing IAC during a simple copying task can be an effective method for reducing forgetting following interruption. IAC was designated Low (all information permanently visible), Medium (a mouse movement to uncover target information), or High (an additional few seconds to uncover such information). Experiment 1 found that recall improved across all three levels of IAC. Subsequent experiments found that High IAC facilitated resumption after interruption, particularly when interruption occurred on half of all trials (Experiment 2), and improved prospective memory following two different interrupting tasks, even when one involved the disruptive effect of using the same type of resource as the primary task (Experiment 3). The improvement of memory after interruption with increased IAC supports the prediction of the soft constraints hypothesis. The main disadvantage of a high access cost was a reduction in speed of task completion. The practicality of manipulating IAC as a design method for inducing a memory-intensive strategy to protect against forgetting is discussed. Copyright 2009 APA

  7. Interruption of the Tower of London Task: Support for a Goal-Activation Approach

    ERIC Educational Resources Information Center

    Hodgetts, Helen M.; Jones, Dylan M.

    2006-01-01

    Unexpected interruptions introduced during the execution phase of simple Tower of London problems incurred a time cost when the interrupted goal was retrieved, and this cost was exacerbated the longer the goal was suspended. Furthermore, time taken to retrieve goals was greater following a more complex interruption, indicating the processing…

  8. Interruptions and Failure in Higher Education: Evidence from ISEG-UTL

    ERIC Educational Resources Information Center

    Chagas, Margarida; Fernandaes, Graca Leao

    2011-01-01

    Failure in higher education (HE) is the outcome of multiple time-dependent determinants. Interruptions in students' individual school trajectories are one of them, and that is why research on this topic has been attracting much attention these days. From an individual point of view, it is expected that interruptions in school trajectory, whatever…

  9. Impact of Frequent Interruption on Nurses' Patient-Controlled Analgesia Programming Performance.

    PubMed

    Campoe, Kristi R; Giuliano, Karen K

    2017-12-01

    The purpose was to add to the body of knowledge regarding the impact of interruption on acute care nurses' cognitive workload, total task completion times, nurse frustration, and medication administration error while programming a patient-controlled analgesia (PCA) pump. Data support that the severity of medication administration error increases with the number of interruptions, which is especially critical during the administration of high-risk medications. Bar code technology, interruption-free zones, and medication safety vests have been shown to decrease administration-related errors. However, there are few published data regarding the impact of number of interruptions on nurses' clinical performance during PCA programming. Nine acute care nurses completed three PCA pump programming tasks in a simulation laboratory. Programming tasks were completed under three conditions where the number of interruptions varied between two, four, and six. Outcome measures included cognitive workload (six NASA Task Load Index [NASA-TLX] subscales), total task completion time (seconds), nurse frustration (NASA-TLX Subscale 6), and PCA medication administration error (incorrect final programming). Increases in the number of interruptions were associated with significant increases in total task completion time ( p = .003). We also found increases in nurses' cognitive workload, nurse frustration, and PCA pump programming errors, but these increases were not statistically significant. Complex technology use permeates the acute care nursing practice environment. These results add new knowledge on nurses' clinical performance during PCA pump programming and high-risk medication administration.

  10. The Classical Vacuum.

    ERIC Educational Resources Information Center

    Boyer, Timothy H.

    1985-01-01

    The classical vacuum of physics is not empty, but contains a distinctive pattern of electromagnetic fields. Discovery of the vacuum, thermal spectrum, classical electron theory, zero-point spectrum, and effects of acceleration are discussed. Connection between thermal radiation and the classical vacuum reveals unexpected unity in the laws of…

  11. Electroweak vacuum instability and renormalized Higgs field vacuum fluctuations in the inflationary universe

    NASA Astrophysics Data System (ADS)

    Kohri, Kazunori; Matsui, Hiroki

    2017-08-01

    In this work, we investigated the electroweak vacuum instability during or after inflation. In the inflationary Universe, i.e., de Sitter space, the vacuum field fluctuations < δ phi 2 > enlarge in proportion to the Hubble scale H2. Therefore, the large inflationary vacuum fluctuations of the Higgs field < δ phi 2 > are potentially catastrophic to trigger the vacuum transition to the negative-energy Planck-scale vacuum state and cause an immediate collapse of the Universe. However, the vacuum field fluctuations < δ phi 2 >, i.e., the vacuum expectation values have an ultraviolet divergence, and therefore a renormalization is necessary to estimate the physical effects of the vacuum transition. Thus, in this paper, we revisit the electroweak vacuum instability from the perspective of quantum field theory (QFT) in curved space-time, and discuss the dynamical behavior of the homogeneous Higgs field phi determined by the effective potential V eff( phi ) in curved space-time and the renormalized vacuum fluctuations < δ phi 2 >ren via adiabatic regularization and point-splitting regularization. We simply suppose that the Higgs field only couples the gravity via the non-minimal Higgs-gravity coupling ξ(μ). In this scenario, the electroweak vacuum stability is inevitably threatened by the dynamical behavior of the homogeneous Higgs field phi, or the formations of AdS domains or bubbles unless the Hubble scale is small enough H< ΛI .

  12. Selective attention as a protagonist in contemporary workplace stress: implications for the interruption age.

    PubMed

    Tams, Stefan; Thatcher, Jason; Grover, Varun; Pak, Richard

    2015-01-01

    The ubiquity of instant messages and email notifications in contemporary work environments has opened a Pandora's Box. This box is filled with countless interruptions coming from laptops, smartphones, and other devices, all of which constantly call for employees' attention. In this interruption era, workplace stress is a pervasive problem. To examine this problem, the present study hypothesizes that the three-way interaction among the frequency with which interrupting stimuli appear, their salience, and employees' deficits in inhibiting attentional responses to them impacts mental workload perceptions, ultimately leading to stress. The study, further, probes a related form of self-efficacy as a potential suppressor of interruption-based stress. The study used a 2 (low vs. high frequency) × 2 (low vs. high salience) mixed model design. The 128 subjects completed a test of their inhibitory deficits and rated their mental workload perceptions and experiences of stress following a computer-based task. Inhibitory deficits and increased interruption salience can alter the perception of mental workload in contemporary work environments for the worse, but interruption self-efficacy can help offset any resulting interruption-based stress. This study extends the literatures on work interruptions as well as on stress and coping in the workplace.

  13. Germanium detector vacuum encapsulation

    NASA Technical Reports Server (NTRS)

    Madden, N. W.; Malone, D. F.; Pehl, R. H.; Cork, C. P.; Luke, P. N.; Landis, D. A.; Pollard, M. J.

    1991-01-01

    This paper describes an encapsulation technology that should significantly improve the viability of germanium gamma-ray detectors for a number of important applications. A specialized vacuum chamber has been constructed in which the detector and the encapsulating module are processed in high vacuum. Very high vacuum conductance is achieved within the valveless encapsulating module. The detector module is then sealed without breaking the chamber vacuum. The details of the vacuum chamber, valveless module, processing, and sealing method are presented.

  14. Apparatus for and method of testing an electrical ground fault circuit interrupt device

    DOEpatents

    Andrews, L.B.

    1998-08-18

    An apparatus for testing a ground fault circuit interrupt device includes a processor, an input device connected to the processor for receiving input from an operator, a storage media connected to the processor for storing test data, an output device connected to the processor for outputting information corresponding to the test data to the operator, and a calibrated variable load circuit connected between the processor and the ground fault circuit interrupt device. The ground fault circuit interrupt device is configured to trip a corresponding circuit breaker. The processor is configured to receive signals from the calibrated variable load circuit and to process the signals to determine a trip threshold current and/or a trip time. A method of testing the ground fault circuit interrupt device includes a first step of providing an identification for the ground fault circuit interrupt device. Test data is then recorded in accordance with the identification. By comparing test data from an initial test with test data from a subsequent test, a trend of performance for the ground fault circuit interrupt device is determined. 17 figs.

  15. Apparatus for and method of testing an electrical ground fault circuit interrupt device

    DOEpatents

    Andrews, Lowell B.

    1998-01-01

    An apparatus for testing a ground fault circuit interrupt device includes a processor, an input device connected to the processor for receiving input from an operator, a storage media connected to the processor for storing test data, an output device connected to the processor for outputting information corresponding to the test data to the operator, and a calibrated variable load circuit connected between the processor and the ground fault circuit interrupt device. The ground fault circuit interrupt device is configured to trip a corresponding circuit breaker. The processor is configured to receive signals from the calibrated variable load circuit and to process the signals to determine a trip threshold current and/or a trip time. A method of testing the ground fault circuit interrupt device includes a first step of providing an identification for the ground fault circuit interrupt device. Test data is then recorded in accordance with the identification. By comparing test data from an initial test with test data from a subsequent test, a trend of performance for the ground fault circuit interrupt device is determined.

  16. Education Interrupted: Kosovo 1980-1999

    ERIC Educational Resources Information Center

    Llapi, Gjylbehare; Peterson, Claudette M.

    2015-01-01

    The period between 1980 and 1999 was one of interruption of education for Albanian students in Kosovo. Serbian students were allowed to attend school, which was now taught in the Serbian language that excluded Albanians. A parallel system of education evolved in which secret house-schools were established in order to educate Albanian speakers in…

  17. Electroweak vacuum instability and renormalized Higgs field vacuum fluctuations in the inflationary universe

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kohri, Kazunori; Matsui, Hiroki, E-mail: kohri@post.kek.jp, E-mail: matshiro@post.kek.jp

    In this work, we investigated the electroweak vacuum instability during or after inflation. In the inflationary Universe, i.e., de Sitter space, the vacuum field fluctuations < δ φ {sup 2} > enlarge in proportion to the Hubble scale H {sup 2}. Therefore, the large inflationary vacuum fluctuations of the Higgs field < δ φ {sup 2} > are potentially catastrophic to trigger the vacuum transition to the negative-energy Planck-scale vacuum state and cause an immediate collapse of the Universe. However, the vacuum field fluctuations < δ φ {sup 2} >, i.e., the vacuum expectation values have an ultraviolet divergence, andmore » therefore a renormalization is necessary to estimate the physical effects of the vacuum transition. Thus, in this paper, we revisit the electroweak vacuum instability from the perspective of quantum field theory (QFT) in curved space-time, and discuss the dynamical behavior of the homogeneous Higgs field φ determined by the effective potential V {sub eff}( φ ) in curved space-time and the renormalized vacuum fluctuations < δ φ {sup 2} >{sub ren} via adiabatic regularization and point-splitting regularization. We simply suppose that the Higgs field only couples the gravity via the non-minimal Higgs-gravity coupling ξ(μ). In this scenario, the electroweak vacuum stability is inevitably threatened by the dynamical behavior of the homogeneous Higgs field φ, or the formations of AdS domains or bubbles unless the Hubble scale is small enough H < Λ {sub I} .« less

  18. A 2.5 Gigawatt Liquid Dielectric Coaxial Pulse Forming Line

    DTIC Science & Technology

    1987-06-01

    operation. The fuses provide protection against long term faults. The 3 phase vacuum contactor is a convenient means of remotely applying or...is electronically sensed and the vacuum contactor opens thereby interrupting the input power. The opening time of the vacuum contactor is less than...less than 5 microseconds and at the same time a trigger signal is sent to the vacuum contactor which opens and interrupts the primary power. The PFL

  19. Procedural Error and Task Interruption

    DTIC Science & Technology

    2016-09-30

    red for research on errors and individual differences . Results indicate predictive validity for fluid intelligence and specifi c forms of work...TERMS procedural error, task interruption, individual differences , fluid intelligence, sleep deprivation 16. SECURITY CLASSIFICATION OF: 17...and individual differences . It generates rich data on several kinds of errors, including procedural errors in which steps are skipped or repeated

  20. Inheritance patterns of ATCCT repeat interruptions in spinocerebellar ataxia type 10 (SCA10) expansions.

    PubMed

    Landrian, Ivette; McFarland, Karen N; Liu, Jilin; Mulligan, Connie J; Rasmussen, Astrid; Ashizawa, Tetsuo

    2017-01-01

    Spinocerebellar ataxia type 10 (SCA10), an autosomal dominant cerebellar ataxia disorder, is caused by a non-coding ATTCT microsatellite repeat expansion in the ataxin 10 gene. In a subset of SCA10 families, the 5'-end of the repeat expansion contains a complex sequence of penta- and heptanucleotide interruption motifs which is followed by a pure tract of tandem ATCCT repeats of unknown length at its 3'-end. Intriguingly, expansions that carry these interruption motifs correlate with an epileptic seizure phenotype and are unstable despite the theory that interruptions are expected to stabilize expanded repeats. To examine the apparent contradiction of unstable, interruption-positive SCA10 expansion alleles and to determine whether the instability originates outside of the interrupted region, we sequenced approximately 1 kb of the 5'-end of SCA10 expansions using the ATCCT-PCR product in individuals across multiple generations from four SCA10 families. We found that the greatest instability within this region occurred in paternal transmissions of the allele in stretches of pure ATTCT motifs while the intervening interrupted sequences were stable. Overall, the ATCCT interruption changes by only one to three repeat units and therefore cannot account for the instability across the length of the disease allele. We conclude that the AT-rich interruptions locally stabilize the SCA10 expansion at the 5'-end but do not completely abolish instability across the entire span of the expansion. In addition, analysis of the interruption alleles across these families support a parsimonious single origin of the mutation with a shared distant ancestor.

  1. Optimal treatment interruptions control of TB transmission model

    NASA Astrophysics Data System (ADS)

    Nainggolan, Jonner; Suparwati, Titik; Kawuwung, Westy B.

    2018-03-01

    A tuberculosis model which incorporates treatment interruptions of infectives is established. Optimal control of individuals infected with active TB is given in the model. It is obtained that the control reproduction numbers is smaller than the reproduction number, this means treatment controls could optimize the decrease in the spread of active TB. For this model, controls on treatment of infection individuals to reduce the actively infected individual populations, by application the Pontryagins Maximum Principle for optimal control. The result further emphasized the importance of controlling disease relapse in reducing the number of actively infected and treatment interruptions individuals with tuberculosis.

  2. Delayed electron emission in strong-field driven tunnelling from a metallic nanotip in the multi-electron regime

    PubMed Central

    Yanagisawa, Hirofumi; Schnepp, Sascha; Hafner, Christian; Hengsberger, Matthias; Kim, Dong Eon; Kling, Matthias F.; Landsman, Alexandra; Gallmann, Lukas; Osterwalder, Jürg

    2016-01-01

    Illuminating a nano-sized metallic tip with ultrashort laser pulses leads to the emission of electrons due to multiphoton excitations. As optical fields become stronger, tunnelling emission directly from the Fermi level becomes prevalent. This can generate coherent electron waves in vacuum leading to a variety of attosecond phenomena. Working at high emission currents where multi-electron effects are significant, we were able to characterize the transition from one regime to the other. Specifically, we found that the onset of laser-driven tunnelling emission is heralded by the appearance of a peculiar delayed emission channel. In this channel, the electrons emitted via laser-driven tunnelling emission are driven back into the metal, and some of the electrons reappear in the vacuum with some delay time after undergoing inelastic scattering and cascading processes inside the metal. Our understanding of these processes gives insights on attosecond tunnelling emission from solids and should prove useful in designing new types of pulsed electron sources. PMID:27786287

  3. Applying social network analysis to the examination of interruptions in healthcare.

    PubMed

    McCurdie, Tara; Sanderson, Penelope; Aitken, Leanne M

    2018-02-01

    Examinations of interruptions in healthcare often focus on a single clinical discipline, and solutions are targeted accordingly. This approach does not take into account the inter-disciplinary dependencies and other sociotechnical aspects that make up the healthcare work system, and suggested solutions may not meet the needs of all stakeholders. In this article a sociotechnical systems perspective is used to uncover the interdependencies between 16 unique work roles that result in interruptions in an intensive care unit (ICU). By applying social network analysis techniques to data collected using the Dual Perspectives Method, we identified targeted systems-based interventions that may reduce unnecessary interruptions while avoiding unintended consequences that impose additional burden on ICU staff. The rich insights gained into the interruptive communication patterns in the ICU work system stand in contrast to findings that would have otherwise been obtained by focusing only on a single clinical discipline or a single perspective. Copyright © 2017. Published by Elsevier Ltd.

  4. A work observation study of nuclear medicine technologists: interruptions, resilience and implications for patient safety

    PubMed Central

    Larcos, George; Prgomet, Mirela; Georgiou, Andrew; Westbrook, Johanna

    2017-01-01

    Background Errors by nuclear medicine technologists during the preparation of radiopharmaceuticals or at other times can cause patient harm and may reflect the impact of interruptions, busy work environments and deficient systems or processes. We aimed to: (a) characterise the rate and nature of interruptions technologists experience and (b) identify strategies that support safety. Methods We performed 100 hours of observation of 11 technologists at a major public hospital and measured the proportions of time spent in eight categories of work tasks, location of task, interruption rate and type and multitasking (tasks conducted in parallel). We catalogued specific safety-oriented strategies used by technologists. Results Technologists completed 5227 tasks and experienced 569 interruptions (mean, 4.5 times per hour; 95% CI 4.1 to 4.9). The highest interruption rate occurred when technologists were in transit between rooms (10.3 per hour (95% CI 8.3 to 12.5)). Interruptions during radiopharmaceutical preparation occurred a mean of 4.4 times per hour (95% CI 3.3 to 5.6). Most (n=426) tasks were interrupted once only and all tasks were resumed after interruption. Multitasking occurred 16.6% of the time. At least some interruptions were initiated by other technologists to convey important information and/or to render assistance. Technologists employed a variety of verbal and non-verbal strategies in all work areas (notably in the hot-lab) to minimise the impact of interruptions and optimise the safe conduct of procedures. Although most were due to individual choices, some strategies reflected overt or subliminal departmental policy. Conclusions Some interruptions appear beneficial. Technologists' self-initiated strategies to support safe work practices appear to be an important element in supporting a resilient work environment in nuclear medicine. PMID:27707869

  5. [Current situation of enteral nutrition interruptions in sepsis children in pediatric intensive care unit].

    PubMed

    Fang, B L; Qian, S Y; Jia, X L; Li, Z; Liu, J

    2016-09-01

    To analyze the interruptions of enteral nutrition (EN) and it's relationship to prognosis in children with sepsis in pediatric intensive care unit (PICU). Daily EN intake and reasons for EN interruptions were prospectively observed and recorded in children with sepsis who were admitted to our PICU from November 2012 to April 2013. Clinical prognosis was compared between children with and without EN interruptions by t, rank-sum and χ(2) tests. Totally 60 consecutive children were included, 42 males, median age 9.67 (5.36, 37.0) months; 50 children suffered from EN interruptions, while 10 children did not. Median time to EN initiation was 2.59 (1.53, 3.67) h; EN was interrupted in 83% (50/60) of children, for a total of 108 times and 696 h, the most common reasons were fibrobronchoscopy and radiologic procedures, 27 and 29 times respectively. Children spent 0.04 (0.02, 0.08) of their total observation period without EN nutrition due to EN interruptions, and was not correlated with pediatric critically ill score (r=0.12, P=0.38). Children with EN interruptions suffered from longer PICU duration ((12±7) vs. (7±4) d, t=2.18, P=0.03), but there was no significant difference in the 28(th) hospital day's mortality between these two groups (6 cases vs. 1 case, χ(2)=0.00, P=1.00). EN is frequently interrupted due to procedures needed fasting, EN intolerance and other reasons in children with sepsis. EN interruptions may have something to do with prolonged PICU length of stay, but the relationship needs to be examined in future studies.

  6. Radiation hard vacuum switch

    DOEpatents

    Boettcher, Gordon E.

    1990-01-01

    A vacuum switch with an isolated trigger probe which is not directly connected to the switching electrodes. The vacuum switch within the plasmatron is triggered by plasma expansion initiated by the trigger probe which travels through an opening to reach the vacuum switch elements. The plasma arc created is directed by the opening to the space between the anode and cathode of the vacuum switch to cause conduction.

  7. Radiation hard vacuum switch

    DOEpatents

    Boettcher, Gordon E.

    1990-03-06

    A vacuum switch with an isolated trigger probe which is not directly connected to the switching electrodes. The vacuum switch within the plasmatron is triggered by plasma expansion initiated by the trigger probe which travels through an opening to reach the vacuum switch elements. The plasma arc created is directed by the opening to the space between the anode and cathode of the vacuum switch to cause conduction.

  8. Cyclic fatigue resistance of two nickel-titanium rotary instruments in interrupted rotation.

    PubMed

    Pedullà, E; Lizio, A; Scibilia, M; Grande, N M; Plotino, G; Boninelli, S; Rapisarda, E; Lo Giudice, G

    2017-02-01

    To investigate the influence of interrupted rotation on cyclic fatigue of two nickel-titanium rotary instruments. Cyclic fatigue of 300 new ProTaper Next size X1; X2 and Mtwo size 10, .04 taper; size 15, .05 taper; size 20, .06 taper and size 25, .06 taper instruments was tested in continuous or interrupted rotation. Fifty files of the same brand and size were randomly assigned to five groups (n = 10). Group 1 instruments were tested in continuous rotation; groups 2 and 3 in paused rotation for 1 s every 10 or 20 s, respectively; groups 4 and 5 in interrupted rotation for 5 s every 10 or 20 s, respectively. Cyclic fatigue was expressed in time to fracture (TtF) in an artificial canal with 60° angle and 5 mm radius of curvature. The fracture surface was examined with a scanning electron microscope (SEM). Data were evaluated by two-way analysis of variance. Cyclic fatigue of groups 2 and 4 of ProTaper Next X2 and Mtwo size 25, .06 taper was significantly lower than that of group 1 of the same instruments (P < 0.01). ProTaper Next X2 had significantly reduced cyclic fatigue in groups 3 and 5 (P < 0.05). No differences were found by interrupting the rotation for 1 or 5 s in all instruments (P > 0.05). Fatigue of other instruments was not affected by interrupted rotation (P > 0.05). Interrupted rotation reduced cyclic fatigue resistance of ProTaper Next X2 and Mtwo size 25, .06 taper, especially when a higher number of interruptions was performed. © 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  9. Wall-ablative laser-driven in-tube accelerator

    NASA Astrophysics Data System (ADS)

    Sasoh, Akihiro; Suzuki, Shingo; Matsuda, Atsushi

    2008-05-01

    The laser-driven in-tube accelerator in which the propellant is supplied from laser-ablated gas from the tube wall was developed. Proof-of concept demonstrations of vertical launch were successfully done. The device had a 25mm X 25mm square cross-section; two opposing walls were made of polyacetal and acted as the propellant, the other two acrylic window with guide grooves to the projectile. The upper end of the launch tube was connected to a vacuum chamber of an inner volume of 0.8 m2, in which the initial pressure was set to lower than 20 Pa. With plugging the bottom end of the launch tube, a momentum coupling coefficient exceeding 2.5 mN/W was obtained. Even with the bottom end connected to the same vacuum chamber through a different duct, the projectile was vertical launched successfully, obtaining 0.14 mN/W.

  10. Vacuum fluctuations in an ancestor vacuum: A possible dark energy candidate

    NASA Astrophysics Data System (ADS)

    Aoki, Hajime; Iso, Satoshi; Lee, Da-Shin; Sekino, Yasuhiro; Yeh, Chen-Pin

    2018-02-01

    We consider an open universe created by bubble nucleation, and study possible effects of our "ancestor vacuum," a de Sitter space in which bubble nucleation occurred, on the present universe. We compute vacuum expectation values of the energy-momentum tensor for a minimally coupled scalar field, carefully taking into account the effect of the ancestor vacuum by the Euclidean prescription. We pay particular attention to the so-called supercurvature mode, a non-normalizable mode on a spatial slice of the open universe, which has been known to exist for sufficiently light fields. This mode decays in time most slowly, and may leave residual effects of the ancestor vacuum, potentially observable in the present universe. We point out that the vacuum energy of the quantum field can be regarded as dark energy if mass of the field is of order the present Hubble parameter or smaller. We obtain preliminary results for the dark energy equation of state w (z ) as a function of the redshift.

  11. A work observation study of nuclear medicine technologists: interruptions, resilience and implications for patient safety.

    PubMed

    Larcos, George; Prgomet, Mirela; Georgiou, Andrew; Westbrook, Johanna

    2017-06-01

    Errors by nuclear medicine technologists during the preparation of radiopharmaceuticals or at other times can cause patient harm and may reflect the impact of interruptions, busy work environments and deficient systems or processes. We aimed to: (a) characterise the rate and nature of interruptions technologists experience and (b) identify strategies that support safety. We performed 100 hours of observation of 11 technologists at a major public hospital and measured the proportions of time spent in eight categories of work tasks, location of task, interruption rate and type and multitasking (tasks conducted in parallel). We catalogued specific safety-oriented strategies used by technologists. Technologists completed 5227 tasks and experienced 569 interruptions (mean, 4.5 times per hour; 95% CI 4.1 to 4.9). The highest interruption rate occurred when technologists were in transit between rooms (10.3 per hour (95% CI 8.3 to 12.5)). Interruptions during radiopharmaceutical preparation occurred a mean of 4.4 times per hour (95% CI 3.3 to 5.6). Most (n=426) tasks were interrupted once only and all tasks were resumed after interruption. Multitasking occurred 16.6% of the time. At least some interruptions were initiated by other technologists to convey important information and/or to render assistance. Technologists employed a variety of verbal and non-verbal strategies in all work areas (notably in the hot-lab) to minimise the impact of interruptions and optimise the safe conduct of procedures. Although most were due to individual choices, some strategies reflected overt or subliminal departmental policy. Some interruptions appear beneficial. Technologists' self-initiated strategies to support safe work practices appear to be an important element in supporting a resilient work environment in nuclear medicine. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  12. Various DC-driven point-to-plain discharges as non-thermal plasma sources and their bactericidal effects

    NASA Astrophysics Data System (ADS)

    Khun, Josef; Scholtz, Vladimír; Hozák, Pavel; Fitl, Přemysl; Julák, Jaroslav

    2018-06-01

    The appearance of several types of ballast serial impedance-stabilized DC-driven electric corona discharges in the point-to-plane configuration is described. In addition to well-known corona discharges, new ones were observed, namely curved transient spark, interrupted channel and branched transient spark. Their properties are described by volt-ampere characteristics and UV-vis emission spectra. Their bactericidal ability for two bacterial species is also given.

  13. Post-arc current simulation based on measurement in vacuum circuit breaker with a one-dimensional particle-in-cell model

    NASA Astrophysics Data System (ADS)

    Jia, Shenli; Mo, Yongpeng; Shi, Zongqian; Li, Junliang; Wang, Lijun

    2017-10-01

    The post-arc dielectric recovery process has a decisive effect on the current interruption performance in a vacuum circuit breaker. The dissipation of residual plasma at the moment of current zero under the transient recovery voltage, which is the first stage of the post-arc dielectric recovery process and forms the post-arc current, has attracted many concerns. A one-dimensional particle-in-cell model is developed to simulate the measured post-arc current in the vacuum circuit breaker in this paper. At first, the parameters of the residual plasma are estimated roughly by the waveform of the post-arc current which is taken from measurements. After that, different components of the post-arc current, which are formed by the movement of charged particles in the residual plasma, are discussed. Then, the residual plasma density is adjusted according to the proportion of electrons and ions absorbed by the post-arc anode derived from the particle-in-cell simulation. After this adjustment, the post-arc current waveform obtained from the simulation is closer to that obtained from measurements.

  14. Vacuum Virtues

    ERIC Educational Resources Information Center

    Rathey, Allen

    2007-01-01

    Upright vacuums, like cars, vary in quality, features and performance. Like automobiles, some uprights are reliable, others may be problematic, and some become a problem as a result of neglect or improper use. So, how do education institutions make an informed choice and, having done so, ensure that an upright vacuum goes the distance? In this…

  15. Microfabricated triggered vacuum switch

    DOEpatents

    Roesler, Alexander W [Tijeras, NM; Schare, Joshua M [Albuquerque, NM; Bunch, Kyle [Albuquerque, NM

    2010-05-11

    A microfabricated vacuum switch is disclosed which includes a substrate upon which an anode, cathode and trigger electrode are located. A cover is sealed over the substrate under vacuum to complete the vacuum switch. In some embodiments of the present invention, a metal cover can be used in place of the trigger electrode on the substrate. Materials used for the vacuum switch are compatible with high vacuum, relatively high temperature processing. These materials include molybdenum, niobium, copper, tungsten, aluminum and alloys thereof for the anode and cathode. Carbon in the form of graphitic carbon, a diamond-like material, or carbon nanotubes can be used in the trigger electrode. Channels can be optionally formed in the substrate to mitigate against surface breakdown.

  16. Effect of current vehicle’s interruption on traffic stability in cooperative car-following theory

    NASA Astrophysics Data System (ADS)

    Zhang, Geng; Liu, Hui

    2017-12-01

    To reveal the impact of the current vehicle’s interruption information on traffic flow, a new car-following model with consideration of the current vehicle’s interruption is proposed and the influence of the current vehicle’s interruption on traffic stability is investigated through theoretical analysis and numerical simulation. By linear analysis, the linear stability condition of the new model is obtained and the negative influence of the current vehicle’s interruption on traffic stability is shown in the headway-sensitivity space. Through nonlinear analysis, the modified Korteweg-de Vries (mKdV) equation of the new model near the critical point is derived and it can be used to describe the propagating behavior of the traffic density wave. Finally, numerical simulation confirms the analytical results, which shows that the current vehicle’s interruption information can destabilize traffic flow and should be considered in real traffic.

  17. Estimating subglottal pressure via airflow interruption with auditory masking.

    PubMed

    Hoffman, Matthew R; Jiang, Jack J

    2009-11-01

    Current noninvasive measurement of subglottal pressure using airflow interruption often produces inconsistent results due to the elicitation of audio-laryngeal reflexes. Auditory feedback could be considered as a means of ensuring measurement accuracy and precision. The purpose of this study was to determine if auditory masking could be used with the airflow interruption system to improve intrasubject consistency. A prerecorded sample of subject phonation was played on a loop over headphones during the trials with auditory masking. This provided subjects with a target pitch and blocked out distracting ambient noise created by the airflow interrupter. Subglottal pressure was noninvasively measured using the airflow interruption system. Thirty subjects, divided into two equal groups, performed 10 trials without auditory masking and 10 trials with auditory masking. Group one performed the normal trials first, followed by the trials with auditory masking. Group two performed the auditory masking trials first, followed by the normal trials. Intrasubject consistency was improved by adding auditory masking, resulting in a decrease in average intrasubject standard deviation from 0.93+/-0.51 to 0.47+/-0.22 cm H(2)O (P < 0.001). Auditory masking can be used effectively to combat audio-laryngeal reflexes and aid subjects in maintaining constant glottal configuration and frequency, thereby increasing intrasubject consistency when measuring subglottal pressure. By considering auditory feedback, a more reliable method of measurement was developed. This method could be used by clinicians, as reliable, immediately available values of subglottal pressure are useful in evaluating laryngeal health and monitoring treatment progress.

  18. Auditory training of speech recognition with interrupted and continuous noise maskers by children with hearing impairment

    PubMed Central

    Sullivan, Jessica R.; Thibodeau, Linda M.; Assmann, Peter F.

    2013-01-01

    Previous studies have indicated that individuals with normal hearing (NH) experience a perceptual advantage for speech recognition in interrupted noise compared to continuous noise. In contrast, adults with hearing impairment (HI) and younger children with NH receive a minimal benefit. The objective of this investigation was to assess whether auditory training in interrupted noise would improve speech recognition in noise for children with HI and perhaps enhance their utilization of glimpsing skills. A partially-repeated measures design was used to evaluate the effectiveness of seven 1-h sessions of auditory training in interrupted and continuous noise. Speech recognition scores in interrupted and continuous noise were obtained from pre-, post-, and 3 months post-training from 24 children with moderate-to-severe hearing loss. Children who participated in auditory training in interrupted noise demonstrated a significantly greater improvement in speech recognition compared to those who trained in continuous noise. Those who trained in interrupted noise demonstrated similar improvements in both noise conditions while those who trained in continuous noise only showed modest improvements in the interrupted noise condition. This study presents direct evidence that auditory training in interrupted noise can be beneficial in improving speech recognition in noise for children with HI. PMID:23297921

  19. A Matter of Urgency: Reducing Clinical Text Message Interruptions During Educational Sessions.

    PubMed

    Mendel, Arielle; Lott, Anthony; Lo, Lisha; Wu, Robert

    2018-04-25

    Text messaging is increasingly replacing paging as a tool to reach physicians on medical wards. However, this phenomenon has resulted in high volumes of nonurgent messages that can disrupt the learning climate. Our objective was to reduce nonurgent educational interruptions to residents on general internal medicine. This was a quality improvement project conducted at an academic hospital network. Measurements and interventions took place on 8 general internal medicine inpatient teaching teams. Interventions included (1) refining the clinical communication process in collaboration with nursing leadership; (2) disseminating guidelines with posters at nursing stations; (3) introducing a noninterrupting option for message senders; (4) audit and feedback of messages; (5) adding an alert for message senders advising if a message would interrupt educational sessions; and (6) training and support to nurses and residents. Interruptions (text messages, phone calls, emails) received by institution-supplied team smartphones were tracked during educational hours using statistical process control charts. A 1-month record of text message content was analyzed for urgency at baseline and following the interventions. The interruption frequency decreased from a mean of 0.92 (95% CI, 0.88 to 0.97) to 0.59 (95% CI, 0.51 to0.67) messages per team per educational hour from January 2014 to December 2016. The proportion of nonurgent educational interruptions decreased from 223/273 (82%) messages over one month to 123/182 (68%; P < .01). Creation of communication guidelines and modification of text message interface with feedback from end-users were associated with a reduction in nonurgent educational interruptions. Continuous audit and feedback may be necessary to minimize nonurgent messages that disrupt educational sessions. © 2018 Society of Hospital Medicine.

  20. Actively driven thermal radiation shield

    DOEpatents

    Madden, Norman W.; Cork, Christopher P.; Becker, John A.; Knapp, David A.

    2002-01-01

    A thermal radiation shield for cooled portable gamma-ray spectrometers. The thermal radiation shield is located intermediate the vacuum enclosure and detector enclosure, is actively driven, and is useful in reducing the heat load to mechanical cooler and additionally extends the lifetime of the mechanical cooler. The thermal shield is electrically-powered and is particularly useful for portable solid-state gamma-ray detectors or spectrometers that dramatically reduces the cooling power requirements. For example, the operating shield at 260K (40K below room temperature) will decrease the thermal radiation load to the detector by 50%, which makes possible portable battery operation for a mechanically cooled Ge spectrometer.

  1. A New Method for Raising Opening Velocity of Electromagnetic Actuated Vacuum Circuit Breaker

    NASA Astrophysics Data System (ADS)

    Tsukima, Mitsuru; Takeuchi, Toshie; Koyama, Kenichi; Yoshiyasu, Hajimu

    Recently an electromagnetic actuator has been widely used as an operating mechanism for the vacuum circuit breaker (VCB). The opening velocity of the contact is supposed to be strongly related with current interruption performance. This paper presents a simple and new technique that raises opening velocity of the electromagnetic actuated VCB. In order to investigate this reason, we built a numerical simulator that predicts the dynamic characteristics of the VCB contact. It takes into account of the magnetic behavior in the actuator and is also coupled with the external control circuit. According to this simulation, it is shown that it is originated from the sharp rise in the electromagnetic thrust force due to the selective saturation of the magnetic yoke. As the result of our experiments, by this technique the opening velocity was verified to be 1.5 times faster than by the conventional way.

  2. The retraction of the protoplast during PCD is an active, and interruptible, calcium-flux driven process.

    PubMed

    Kacprzyk, Joanna; Brogan, Niall P; Daly, Cara T; Doyle, Siamsa M; Diamond, Mark; Molony, Elizabeth M; McCabe, Paul F

    2017-07-01

    The protoplast retracts during apoptosis-like programmed cell death (AL-PCD) and, if this retraction is an active component of AL-PCD, it should be used as a defining feature for this type of programmed cell death. We used an array of pharmacological and genetic tools to test if the rates of protoplast retraction in cells undergoing AL-PCD can be modulated. Disturbing calcium flux signalling, ATP synthesis and mitochondrial permeability transition all inhibited protoplast retraction and often also the execution of the death programme. Protoplast retraction can precede loss of plasma membrane integrity and cell death can be interrupted after the protoplast retraction had already occurred. Blocking calcium influx inhibited the protoplast retraction, reduced DNA fragmentation and delayed death induced by AL-PCD associated stresses. At higher levels of stress, where cell death occurs without protoplast retraction, blocking calcium flux had no effect on the death process. The results therefore strongly suggest that retraction of the protoplast is an active biological process dependent on an early Ca 2+ -mediated trigger rather than cellular disintegration due to plasma membrane damage. Therefore this morphologically distinct cell type is a quantifiable feature, and consequently, reporter of AL-PCD. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Interrupted monitoring of a stochastic process

    NASA Technical Reports Server (NTRS)

    Palmer, E.

    1977-01-01

    Normative strategies are developed for tasks where the pilot must interrupt his monitoring of a stochastic process in order to attend to other duties. Results are given as to how characteristics of the stochastic process and the other tasks affect the optimal strategies. The optimum strategy is also compared to the strategies used by subjects in a pilot experiment.

  4. Vacuum probe surface sampler

    NASA Technical Reports Server (NTRS)

    Zahlava, B. A. (Inventor)

    1973-01-01

    A vacuum probe surface sampler is described for rapidly sampling relatively large surface areas which possess relatively light loading densities of micro-organism, drug particles or the like. A vacuum head with a hollow handle connected to a suitable vacuum source is frictionally attached to a cone assembly terminating in a flared tip adapted to be passed over the surface to be sampled. A fine mesh screen carried by the vacuum head provides support for a membrane filter which collects the microorganisms or other particles. The head assembly is easily removed from the cone assembly without contacting the cone assembly with human hands.

  5. Comparison of work rates, energy expenditure, and perceived exertion during a 1-h vacuuming task with a backpack vacuum cleaner and an upright vacuum cleaner.

    PubMed

    Mengelkoch, Larry J; Clark, Kirby

    2006-03-01

    The purpose of this study was to evaluate two types of industrial vacuum cleaners, in terms of cleaning rates, energy expenditure, and perceived exertion. Twelve industrial cleaners (six males and six females, age 28-39 yr) performed two 1-h vacuuming tasks with an upright vacuum cleaner (UVC) and a backpack vacuum cleaner (BPVC). Measures for oxygen uptake (VO2) and ratings of perceived exertion (RPE) were collected continuously during the 1-h vacuuming tasks. Cleaning rates for the UVC and BPVC were 7.23 and 14.98 m2min(-1), respectively. On a separate day subjects performed a maximal treadmill exercise test to determine their maximal aerobic capacity (peak VO2). Average absolute energy costs (in Metabolic equivalents), relative energy costs of the vacuum task compared to the subjects' maximal aerobic capacity (% peak VO2), and RPE responses for the 1-h vacuuming tasks were similar between vacuum cleaners, but % peak VO2 and RPE values differed between genders. These results indicate that the BPVC was more efficient than the UVC. With the BPVC, experienced workers vacuumed at a cleaning rate 2.07 times greater than the UVC and had similar levels of energy expenditure and perceived effort, compared to the slower cleaning rate with the UVC.

  6. Effects of Interrupting Children's Sedentary Behaviors With Activity on Metabolic Function: A Randomized Trial.

    PubMed

    Belcher, Britni R; Berrigan, David; Papachristopoulou, Alexia; Brady, Sheila M; Bernstein, Shanna B; Brychta, Robert J; Hattenbach, Jacob D; Tigner, Ira L; Courville, Amber B; Drinkard, Bart E; Smith, Kevin P; Rosing, Douglas R; Wolters, Pamela L; Chen, Kong Y; Yanovski, Jack A

    2015-10-01

    Limited data suggest that interrupting sedentary behaviors with activity improves metabolic parameters in adults. We tested whether interrupting sitting with short, moderate-intensity walking bouts improved glucose tolerance in children. Participants underwent two experimental conditions in random order on different days: continuous sitting for 3 hours or sitting interrupted by walking (3 min of moderate-intensity walking every 30 min). Insulin, C-peptide, glucose, and free fatty acids were measured every 30 minutes for 3 hours during an oral glucose tolerance test. Area under the curve (AUC) was calculated from hormone and substrate measurements. Children were given a buffet meal after each condition. The study was conducted at the National Institutes of Health Hatfield Clinical Research Center. Twenty-eight normal-weight 7-11 year olds participated. Patterns of substrate/hormone secretion and AUC, as well as energy intake, were examined by experimental condition. Interrupting sitting resulted in a 32% lower insulin AUC (P < .001), 17% lower C-peptide AUC (P < .001), and 7% lower glucose AUC (P = .018) vs continuous sitting. Mixed model results indicated that insulin (P = .036) and free fatty acid concentrations (P = .009) were significantly lower in the interrupted vs the continuous sitting condition. Lunchtime buffet meal energy intake did not significantly differ between the conditions (975 ± 387 vs 963 ± 309 kcal; P = .85). Interrupting sedentary time with brief moderate-intensity walking improved short-term metabolic function in non-overweight children without increasing subsequent energy intake. These findings suggest that interrupting sedentary behavior may be a promising prevention strategy for reducing cardiometabolic risk in children.

  7. Metal glass vacuum tube solar collectors are approaching lower-medium temperature heat application.

    PubMed

    Jiang, Xinian

    2010-04-26

    Solar thermal collectors are widely used worldwide mainly for hot water preparation at a low temperature (less than 80 degrees C). Applications including many industrial processes and central air conditioning with absorption chillers, instead require lower-medium temperature heat (between 90 degrees C and 150 degrees C) to be driven when using solar thermal energy. The metal absorber glass vacuum tube collectors (MGVT) are developed for this type of applications. Current state-of-art and possible future technology development of MGVT are presented.

  8. Metal glass vacuum tube solar collectors are approaching lower-medium temperature heat application.

    PubMed

    Jiang, Xinian

    2010-04-26

    Solar thermal collectors are widely used worldwide mainly for hot water preparation at a low temperature (less than 80?C). Applications including many industrial processes and central air conditioning with absorption chillers, instead require lower-medium temperature heat (between 90 degrees C and 150 degrees C) to be driven when using solar thermal energy. The metal absorber glass vacuum tube collectors (MGVT) are developed for this type of applications. Current state-of-art and possible future technology development of MGVT are presented.

  9. [Vaccine cold chain interruption in a primary care center and economic evaluation].

    PubMed

    Larena Fernández, Israel; Vara Callau, Marta; Peña Blasco, Guillermo; Atance Melendo, Esther; Gay Gasanz, Blanca; Pérez-Aramendía, María Jesús Blasco

    Cold chain control is one of the most important facts to ensure the effectiveness of vaccines links, which requires specific material and human resources for management. The principal objective is to evaluate the interruptions in cold chain of the last 6 years and the possible cost savings that would result in further improvements. A retrospective and descriptive study based on a review of all cold chain interruptions during the last 6 years, at Valdefierro Primary Health Center. We had 5 interruptions, the maximum temperature reached was 23.1±3.4°C and the longest interruption lasted 25.2±20.7hours. 1611 vaccines were affected and 165 discarded. Total economic loss was 2.098,10 € and 33.611,64 € were savings. The electrical failure was the disruption cause in 5 cases. Equipment and staff are essential. The center did some corrective actions, such as minimizing refrigerator time control, minimum stock control, considering population changes, and the center has requested a electrical supply system. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  10. Development of 72kV High Pressure Air-insulated GIS with Vacuum Circuit Breaker

    NASA Astrophysics Data System (ADS)

    Rokunohe, Toshiaki; Yagihashi, Yoshitaka; Endo, Fumihiro; Aoyagi, Kenji; Saitoh, Hitoshi; Oomori, Takashi

    SF6 gas has excellent dielectric strength and interruption performance. For these reasons, it has been widely used for gas insulated switchgear (GIS). However, use of SF6 gas has become regulated under agreements set at the 1997 COP3. So investigation and development for GIS with a lower amount of SF6 gas are being carried out worldwide. Presently, SF6 gas-free GIS has been commercialized for the 24kV class. Air or N2 gas is used as insulation gas for this GIS. On the other hand, SF6 gas-free GIS has not been commercialized for 72kV class GIS. Dielectric strengths of air and N2 gas are approximately 1/3 that of SF6 gas. So to enhance insulation performance of air and N2, we have investigated a hybrid gas insulation system which has the combined features of providing an insulation coating and suitable insulation gas. We have developed the world's first 72kV SF6 gas-free GIS. This paper deals with key technologies for SF6 gas-free GIS such as the hybrid insulation structure, bellows for the high pressure vacuum circuit breaker, a newly designed disconnector and spacer and prevention of particle levitation. Test results of 72kV high pressure air-insulated GIS with the vacuum circuit breaker are described.

  11. Current interruption in inductive storage systems with inertial current source

    NASA Astrophysics Data System (ADS)

    Vitkovitsky, I. M.; Conte, D.; Ford, R. D.; Lupton, W. H.

    1980-03-01

    Utilization of inertial current source inductive storage with high power output requires a switch with short opening time. This switch must operate as a circuit breaker, i.e., be capable to carry the current for a time period characteristic of inertial systems, such as homopolar generators. For reasonable efficiency, its opening time must be fast to minimize the energy dissipated in downstream fuse stages required for any additional pulse compression. A switch that satisfies these criteria, as well as other requirements such as that for high voltage operation associated with high power output, is an explosively driven switch consisting of large number of gaps arranged in series. The performance of this switch in limiting and/or interrupting currents produced by large generators has been studied. Single switch modules were designed and tested for limiting the commutating current output of 1 MW, 60 Hz, generator and 500 KJ capacitor banks. Current limiting and commutation were evaluated, using these sources, for currents ranging up to 0.4 MA. The explosive opening of the switch was found to provide an effective first stage for further pulse compression. It opens in tens of microseconds, commutates current at high efficiency ( = 905) recovers very rapidly over a wide range of operating conditions.

  12. A radiation hard vacuum switch

    DOEpatents

    Boettcher, G.E.

    1988-07-19

    A vacuum switch with an isolated trigger probe which is not directly connected to the switching electrodes. The vacuum switch within the plasmatron is triggered by plasma expansion initiated by the trigger probe which travels through an opening to reach the vacuum switch elements. The plasma arc created is directed by the opening to the space between the anode and cathode of the vacuum switch to cause conduction. 3 figs.

  13. Comparison of vacuum rise time, vacuum limit accuracy, and occlusion break surge of 3 new phacoemulsification systems.

    PubMed

    Han, Young Keun; Miller, Kevin M

    2009-08-01

    To compare vacuum rise time, vacuum limit accuracy, and occlusion break surge of 3 new phacoemulsification machines. Jules Stein Eye Institute and Department of Ophthalmology, David Geffen School of Medicine at UCLA, Los Angeles, California, USA. The vacuum rise time under normal and enhanced aspiration modes, vacuum limit accuracy, and occlusion break surge of the Infiniti Vision System, Stellaris Vision Enhancement System, and WhiteStar Signature Phacoemulsification System were tested. Vacuum rise time and limit accuracy were measured at limit settings of 400 mm Hg and 600 mm Hg. Surge area was recorded at vacuum limit settings of 200 mm Hg, 300 mm Hg, 400 mm Hg, and 500 mm Hg. The Infiniti had the fastest vacuum rise times under normal and enhanced aspiration modes. At 4 seconds, the vacuum limit accuracy was greatest with the Infiniti at the 400 mm Hg limit and the Signature at the 600 mm Hg limit. The Stellaris did not reach either vacuum target. The Infiniti performed better than the other 2 machines during testing of occlusion break surge at all vacuum limit settings above 200 mm Hg. Under controlled laboratory test conditions, the Infiniti had the fastest vacuum rise time, greatest vacuum limit accuracy at 400 mm Hg, and least occlusion break surge. These results can be explained by the lower compliance of the Infiniti system.

  14. Mitigation of PID in commercial PV modules using current interruption method

    NASA Astrophysics Data System (ADS)

    Bora, Birinchi; Oh, Jaewon; Tatapudi, Sai; Sastry, Oruganty S.; Kumar, Rajesh; Prasad, Basudev; Tamizhmani, Govindasamy

    2017-08-01

    Potential-induced degradation (PID) is known to have a very severe effect on the reliability of PV modules. PID is caused due to the leakage of current from the cell circuit to the grounded frame under humid conditions of high voltage photovoltaic (PV) systems. There are multiple paths for the current leakage. The most dominant leakage path is from the cell to the frame through encapsulant, glass bulk and glass surface. This dominant path can be prevented by interrupting the electrical conductivity at the glass surface. In our previous works related to this topic, we demonstrated the effectiveness of glass surface conductivity interruption technique using one-cell PV coupons. In this work, we demonstrate the effectiveness of this technique using a full size commercial module susceptible to PID. The interruption of surface conductivity of the commercial module was achieved by attaching a narrow, thin flexible glass strips, from Corning, called Willow Glass on the glass surface along the inner edges of the frame. The flexible glass strip was attached to the module glass surface by heating the glass strip with an ionomer adhesive underneath using a handheld heat gun. The PID stress test was performed at 60°C and 85% RH for 96 hours at -600 V. Pre- and post-PID characterizations including I-V and electroluminescence were carried out to determine the performance loss and affected cell areas. This work demonstrates that the PID issue can be effectively addressed by using this current interruption technique. An important benefit of this approach is that this interruption technique can be applied after manufacturing the modules and after installing the modules in the field as well.

  15. 18 CFR 284.9 - Interruptible transportation service.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... transportation service. 284.9 Section 284.9 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... AUTHORITIES CERTAIN SALES AND TRANSPORTATION OF NATURAL GAS UNDER THE NATURAL GAS POLICY ACT OF 1978 AND RELATED AUTHORITIES General Provisions and Conditions § 284.9 Interruptible transportation service. (a...

  16. 18 CFR 284.9 - Interruptible transportation service.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... transportation service. 284.9 Section 284.9 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... AUTHORITIES CERTAIN SALES AND TRANSPORTATION OF NATURAL GAS UNDER THE NATURAL GAS POLICY ACT OF 1978 AND RELATED AUTHORITIES General Provisions and Conditions § 284.9 Interruptible transportation service. (a...

  17. 18 CFR 284.9 - Interruptible transportation service.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... transportation service. 284.9 Section 284.9 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... AUTHORITIES CERTAIN SALES AND TRANSPORTATION OF NATURAL GAS UNDER THE NATURAL GAS POLICY ACT OF 1978 AND RELATED AUTHORITIES General Provisions and Conditions § 284.9 Interruptible transportation service. (a...

  18. 18 CFR 284.9 - Interruptible transportation service.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... transportation service. 284.9 Section 284.9 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... AUTHORITIES CERTAIN SALES AND TRANSPORTATION OF NATURAL GAS UNDER THE NATURAL GAS POLICY ACT OF 1978 AND RELATED AUTHORITIES General Provisions and Conditions § 284.9 Interruptible transportation service. (a...

  19. 18 CFR 284.9 - Interruptible transportation service.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... transportation service. 284.9 Section 284.9 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... AUTHORITIES CERTAIN SALES AND TRANSPORTATION OF NATURAL GAS UNDER THE NATURAL GAS POLICY ACT OF 1978 AND RELATED AUTHORITIES General Provisions and Conditions § 284.9 Interruptible transportation service. (a...

  20. Algorithm Design of CPCI Backboard's Interrupts Management Based on VxWorks' Multi-Tasks

    NASA Astrophysics Data System (ADS)

    Cheng, Jingyuan; An, Qi; Yang, Junfeng

    2006-09-01

    This paper begins with a brief introduction of the embedded real-time operating system VxWorks and CompactPCI standard, then gives the programming interfaces of Peripheral Controller Interface (PCI) configuring, interrupts handling and multi-tasks programming interface under VxWorks, and then emphasis is placed on the software frameworks of CPCI interrupt management based on multi-tasks. This method is sound in design and easy to adapt, ensures that all possible interrupts are handled in time, which makes it suitable for data acquisition systems with multi-channels, a high data rate, and hard real-time high energy physics.

  1. Air bearing vacuum seal assembly

    DOEpatents

    Booth, Rex

    1978-01-01

    An air bearing vacuum seal assembly capable of rotating at the speed of several thousand revolutions per minute using an air cushion to prevent the rotating and stationary parts from touching, and a two stage differential pumping arrangement to maintain the pressure gradient between the air cushion and the vacuum so that the leak rate into the vacuum is, for example, less than 1 .times. 10.sup.-4 Pa m.sup.3 /s. The air bearing vacuum seal has particular application for mounting rotating targets to an evacuated accelerator beam tube for bombardment of the targets with high-power charged particle beams in vacuum.

  2. PolyQ repeat expansions in ATXN2 associated with ALS are CAA interrupted repeats.

    PubMed

    Yu, Zhenming; Zhu, Yongqing; Chen-Plotkin, Alice S; Clay-Falcone, Dana; McCluskey, Leo; Elman, Lauren; Kalb, Robert G; Trojanowski, John Q; Lee, Virginia M-Y; Van Deerlin, Vivianna M; Gitler, Aaron D; Bonini, Nancy M

    2011-03-29

    Amyotrophic lateral sclerosis (ALS) is a devastating, rapidly progressive disease leading to paralysis and death. Recently, intermediate length polyglutamine (polyQ) repeats of 27-33 in ATAXIN-2 (ATXN2), encoding the ATXN2 protein, were found to increase risk for ALS. In ATXN2, polyQ expansions of ≥ 34, which are pure CAG repeat expansions, cause spinocerebellar ataxia type 2. However, similar length expansions that are interrupted with other codons, can present atypically with parkinsonism, suggesting that configuration of the repeat sequence plays an important role in disease manifestation in ATXN2 polyQ expansion diseases. Here we determined whether the expansions in ATXN2 associated with ALS were pure or interrupted CAG repeats, and defined single nucleotide polymorphisms (SNPs) rs695871 and rs695872 in exon 1 of the gene, to assess haplotype association. We found that the expanded repeat alleles of 40 ALS patients and 9 long-repeat length controls were all interrupted, bearing 1-3 CAA codons within the CAG repeat. 21/21 expanded ALS chromosomes with 3CAA interruptions arose from one haplotype (GT), while 18/19 expanded ALS chromosomes with <3CAA interruptions arose from a different haplotype (CC). Moreover, age of disease onset was significantly earlier in patients bearing 3 interruptions vs fewer, and was distinct between haplotypes. These results indicate that CAG repeat expansions in ATXN2 associated with ALS are uniformly interrupted repeats and that the nature of the repeat sequence and haplotype, as well as length of polyQ repeat, may play a role in the neurological effect conferred by expansions in ATXN2.

  3. Vacuum-Gauge Connection For Shipping Container

    NASA Technical Reports Server (NTRS)

    Henry, Robert H.

    1990-01-01

    External connector enables measurement of vacuum in stored part. Remote-readout connector added to shipping container and connected to thermo-couple vacuum gauge in vacuum-insulated cryogenic line packed in container. Enables monitoring of condition of vacuum without opening container.

  4. NSLS II Vacuum System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ferreira, M.; Doom, L.; Hseuh, H.

    2009-09-13

    National Synchrotron Light Source II, being constructed at Brookhaven, is a 3-GeV, 500 mA, 3rd generation synchrotron radiation facility with ultra low emittance electron beams. The storage ring vacuum system has a circumference of 792 m and consists of over 250 vacuum chambers with a simulated average operating pressure of less than 1 x 10{sup -9} mbar. A summary of the update design of the vacuum system including girder supports of the chambers, gauges, vacuum pumps, bellows, beam position monitors and simulation of the average pressure will be shown. A brief description of the techniques and procedures for cleaning andmore » mounting the chambers are given.« less

  5. Effective Porosity Measurements by Wet- and Dry-type Vacuum Saturations using Process-Programmable Vacuum Saturation System

    NASA Astrophysics Data System (ADS)

    Lee, T. J.; Lee, K. S., , Dr; Lee, S. K.

    2017-12-01

    One of the most important factors in measuring effective porosity by vacuum saturation method is that the air in the pore space can be fully substituted by water during the vacuum saturation process. International Society of Rock Mechanics (ISRM) suggests vacuuming a rock sample submerged in the water, while American Society of Test and Materials (ASTM) vacuuming the sample and water separately and then pour the water to the sample. In this study, we call the former wet-type vacuum saturation (WVS) method and the latter dry-type vacuum saturation (DVS) method, and compare the effective porosity measured by the two different vacuum saturation processes. For that purpose, a vacuum saturation system has been developed, which can support both WVS and DVS by only changing the process by programming. Comparison of effective porosity has been made for a cement mortar and rock samples. As a result, DVS can substitute more void volume to water than WVS, which in turn insists that DVS can provide more exact value of effective porosity than WVS.

  6. An Assessment of Instant Messaging Interruptions on Knowledge Workers' Task Performance in E-Learning-Based Training

    ERIC Educational Resources Information Center

    Mansi, Gary R.

    2011-01-01

    The modern workplace environment is filled with interruptions due to the necessity of coworkers to communicate with each other. Studies have revealed that interruptions can disrupt the ability of a knowledge worker to concentrate on a task, which can impact task performance (TP). Communication interruptions are due, in part, to the unavoidable…

  7. Physicians interrupted by mobile devices in hospitals: understanding the interaction between devices, roles, and duties.

    PubMed

    Solvoll, Terje; Scholl, Jeremiah; Hartvigsen, Gunnar

    2013-03-07

    A common denominator of modern hospitals is a variety of communication problems. In particular, interruptions from mobile communication devices are a cause of great concern for many physicians. To characterize how interruptions from mobile devices disturb physicians in their daily work. The gathered knowledge will be subsequently used as input for the design and development of a context-sensitive communication system for mobile communications suitable for hospitals. This study adheres to an ethnographic and interpretive field research approach. The data gathering consisted of participant observations, non-structured and mostly ad hoc interviews, and open-ended discussions with a selected group of physicians. Eleven physicians were observed for a total of 135 hours during May and June 2009. The study demonstrates to what degree physicians are interrupted by mobile devices in their daily work and in which situations they are interrupted, such as surgery, examinations, and during patients/relatives high-importance level conversations. The participants in the study expected, and also indicated, that wireless phones probably led to more interruptions immediately after their introduction in a clinic, when compared to a pager, but this changed after a short while. The unpleasant feeling experienced by the caller when interrupting someone by calling them differs compared to sending a page message, which leaves it up to the receiver when to return the call. Mobile devices, which frequently interrupt physicians in hospitals, are a problem for both physicians and patients. The results from this study contribute to knowledge being used as input for designing and developing a prototype for a context-sensitive communication system for mobile communication suitable for hospitals. We combined these findings with results from earlier studies and also involved actual users to develop the prototype, CallMeSmart. This system intends to reduce such interruptions and at the same time

  8. Interrupted Time Series Versus Statistical Process Control in Quality Improvement Projects.

    PubMed

    Andersson Hagiwara, Magnus; Andersson Gäre, Boel; Elg, Mattias

    2016-01-01

    To measure the effect of quality improvement interventions, it is appropriate to use analysis methods that measure data over time. Examples of such methods include statistical process control analysis and interrupted time series with segmented regression analysis. This article compares the use of statistical process control analysis and interrupted time series with segmented regression analysis for evaluating the longitudinal effects of quality improvement interventions, using an example study on an evaluation of a computerized decision support system.

  9. Modeling of breakdown during the post-arc phase of a vacuum circuit breaker

    NASA Astrophysics Data System (ADS)

    Sarrailh, P.; Garrigues, L.; Boeuf, J. P.; Hagelaar, G. J. M.

    2010-12-01

    After a high-current interruption in a vacuum circuit breaker (VCB), the electrode gap is filled with a high density copper vapor plasma in a large copper vapor density (~1022 m-3). The copper vapor density is sustained by electrode evaporation. During the post-arc phase, a rapidly increasing voltage is applied to the gap, and a sheath forms and expands, expelling the plasma from the gap when circuit breaking is successful. There is, however, a risk of breakdown during that phase, leading to the failure of the VCB. Preventing breakdown during the post-arc phase is an important issue for the improvement of VCB reliability. In this paper, we analyze the risk of Townsend breakdown in the high copper vapor density during the post-arc phase using a numerical model that takes into account secondary electron emission, volume ionization, and plasma and neutral transport, for given electrode temperatures. The simulations show that fast neutrals created in the cathode sheath by charge exchange collisions with ions generate a very large secondary electron emission current that can lead to Townsend breakdown. The results also show that the risk of failure of the VCB due to Townsend breakdown strongly depends on the electrode temperatures (which govern the copper vapor density) and becomes important for temperatures greater than 2100 K, which can be reached in vacuum arcs. The simulations also predict that a hotter anode tends to increase the risk of Townsend breakdown.

  10. The Role of Prediction In Perception: Evidence From Interrupted Visual Search

    PubMed Central

    Mereu, Stefania; Zacks, Jeffrey M.; Kurby, Christopher A.; Lleras, Alejandro

    2014-01-01

    Recent studies of rapid resumption—an observer’s ability to quickly resume a visual search after an interruption—suggest that predictions underlie visual perception. Previous studies showed that when the search display changes unpredictably after the interruption, rapid resumption disappears. This conclusion is at odds with our everyday experience, where the visual system seems to be quite efficient despite continuous changes of the visual scene; however, in the real world, changes can typically be anticipated based on previous knowledge. The present study aimed to evaluate whether changes to the visual display can be incorporated into the perceptual hypotheses, if observers are allowed to anticipate such changes. Results strongly suggest that an interrupted visual search can be rapidly resumed even when information in the display has changed after the interruption, so long as participants not only can anticipate them, but also are aware that such changes might occur. PMID:24820440

  11. When daily planning improves employee performance: The importance of planning type, engagement, and interruptions.

    PubMed

    Parke, Michael R; Weinhardt, Justin M; Brodsky, Andrew; Tangirala, Subrahmaniam; DeVoe, Sanford E

    2018-03-01

    Does planning for a particular workday help employees perform better than on other days they fail to plan? We investigate this question by identifying 2 distinct types of daily work planning to explain why and when planning improves employees' daily performance. The first type is time management planning (TMP)-creating task lists, prioritizing tasks, and determining how and when to perform them. We propose that TMP enhances employees' performance by increasing their work engagement, but that these positive effects are weakened when employees face many interruptions in their day. The second type is contingent planning (CP) in which employees anticipate possible interruptions in their work and plan for them. We propose that CP helps employees stay engaged and perform well despite frequent interruptions. We investigate these hypotheses using a 2-week experience-sampling study. Our findings indicate that TMP's positive effects are conditioned upon the amount of interruptions, but CP has positive effects that are not influenced by the level of interruptions. Through this study, we help inform workers of the different planning methods they can use to increase their daily motivation and performance in dynamic work environments. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  12. An evaluation of interrupted and uninterrupted measurement of vocal stereotypy on perceived treatment outcomes.

    PubMed

    Carroll, Regina A; Kodak, Tiffany

    2014-01-01

    The type of procedure used to measure a target behavior may directly influence the perceived treatment outcomes. In the present study, we examined the influence of different data-analysis procedures on the outcomes of two commonly used treatments on the vocal stereotypy of 2 children with an autism spectrum disorder. In Study 1, we compared an interrupted and uninterrupted data-analysis procedure to measure vocal stereotypy during the implementation of response interruption and redirection (RIRD). The results showed that the interrupted data-analysis procedure overestimated the effectiveness of RIRD. In Study 2, we examined the influence of different data-analysis procedures on the interpretation of the relative effects of 2 different treatments for vocal stereotypy. Specifically, we compared interrupted and uninterrupted data-analysis procedures during the implementation of RIRD and noncontingent reinforcement (NCR) as a treatment for vocal stereotypy. The results showed that, as in Study 1, the interrupted data-analysis procedure overestimated the effectiveness of RIRD; however, this effect was not apparent with NCR. These findings suggest that different types of data analysis can influence the perceived success of a treatment. © Society for the Experimental Analysis of Behavior.

  13. Pacifier use and interruption of exclusive breastfeeding: Systematic review and meta-analysis.

    PubMed

    Buccini, Gabriela Dos Santos; Pérez-Escamilla, Rafael; Paulino, Larissa Munari; Araújo, Clarice Lopes; Venancio, Sonia Isoyama

    2017-07-01

    Identifying modifiable risk factor for exclusive breastfeeding (EBF) interruption is key for improving child health globally. There is no consensus about the effect of pacifier use on EBF interruption. Thus, the aim of this systematic review was to investigate the association between pacifier use and EBF interruption during the first six month. A search of CINAHL, Scopus, Web of Science, LILACS and Medline; from inception through 30 December 2014 without restriction of language yielded 1,866 publications (PROSPERO protocol CRD42014014527). Predetermined inclusion/exclusion criteria peer reviewed yielded 46 studies: two clinical trials, 20 longitudinal, and 24 cross-sectional studies. Meta-analysis was performed and meta-regression explored heterogeneity across studies. The pooled effect of the association between pacifier use and EBF interruption was 2.48 OR (95% CI = 2.16-2.85). Heterogeneity was explained by the study design (40.2%), followed by differences in the measurement and categorization of pacifier use, the methodological quality of the studies and the socio-economic context. Two RCT's with very limited external validity found a null association, but 44 observational studies, including 20 prospective cohort studies, did find a consistent association between pacifier use and risk of EBF interruption (OR = 2.28; 95% CI = 1.78-2.93). Our findings support the current WHO recommendation on pacifier use as it focuses on the risk of poor breastfeeding outcomes as a result of pacifier use. Future studies that take into account the risks and benefits of pacifier use are needed to clarify this recommendation. © 2016 John Wiley & Sons Ltd.

  14. Multipurpose Vacuum Induction Processing System

    NASA Astrophysics Data System (ADS)

    Govindaraju, M.; Kulkarni, Deepak; Balasubramanian, K.

    2012-11-01

    Multipurpose vacuum processing systems are cost effective; occupy less space, multiple functional under one roof and user friendly. A multipurpose vacuum induction system was designed, fabricated and installed in a record time of 6 months time at NFTDC Hyderabad. It was designed to function as a) vacuum induction melting/refining of oxygen free electronic copper/pure metals, b) vacuum induction melting furnace for ferrous materials c) vacuum induction melting for non ferrous materials d) large vacuum heat treatment chamber by resistance heating (by detachable coil and hot zone) e) bottom discharge vacuum induction melting system for non ferrous materials f) Induction heat treatment system and g) directional solidification /investment casting. It contains provision for future capacity addition. The attachments require to manufacture multiple shaped castings and continuous rod casting can be added whenever need arises. Present capacity is decided on the requirement for 10years of development path; presently it has 1.2 ton liquid copper handling capacity. It is equipped with provision for capacity addition up to 2 ton liquid copper handling capacity in future. Provision is made to carry out the capacity addition in easy steps quickly. For easy operational maintenance and troubleshooting, design was made in easily detachable sections. High vacuum system is also is detachable, independent and easily movable which is first of its kind in the country. Detailed design parameters, advantages and development history are presented in this paper.

  15. Ethics of treatment interruption trials in HIV cure research: addressing the conundrum of risk/benefit assessment

    PubMed Central

    Henderson, Gail E; Peay, Holly L; Kroon, Eugene; Cadigan, Rosemary Jean; Meagher, Karen; Jupimai, Thidarat; Gilbertson, Adam; Fisher, Jill; Ormsby, Nuchanart Q; Chomchey, Nitiya; Phanuphak, Nittaya; Ananworanich, Jintanat; Rennie, Stuart

    2018-01-01

    Though antiretroviral therapy is the standard of care for people living with HIV, its treatment limitations, burdens, stigma and costs lead to continued interest in HIV cure research. Early-phase cure trials, particularly those that include analytic treatment interruption (ATI), involve uncertain and potentially high risk, with minimal chance of clinical benefit. Some question whether such trials should be offered, given the risk/benefit imbalance, and whether those who choose to participate are acting rationally. We address these questions through a longitudinal decision-making study nested in a Thai acute HIV research cohort. In-depth interviews revealed central themes about decisions to join. Participants felt they possessed an important identity as members of the acute cohort, viewing their bodies as uniquely suited to both testing and potentially benefiting from HIV cure approaches. While acknowledging risks of ATI, most perceived they were given an opportunity to interrupt treatment, to test their own bodies and increase normalcy in a safe, highly monitored circumstance. They were motivated by potential benefits to themselves, the investigators and larger acute cohort, and others with HIV. They believed their own trial experiences and being able to give back to the community were sufficient to offset participation risks. These decisions were driven by the specific circumstances experienced by our participants. Judging risk/benefit ratios without appreciating these lived experiences can lead to false determinations of irrational decision- making. While this does not minimise vital oversight considerations about risk reduction and protection from harm, it argues for inclusion of a more participant-centered approach. PMID:29127137

  16. Vacuum leak detector and method

    DOEpatents

    Edwards, Jr., David

    1983-01-01

    Apparatus and method for detecting leakage in a vacuum system involves a moisture trap chamber connected to the vacuum system and to a pressure gauge. Moisture in the trap chamber is captured by freezing or by a moisture adsorbent to reduce the residual water vapor pressure therein to a negligible amount. The pressure gauge is then read to determine whether the vacuum system is leaky. By directing a stream of carbon dioxide or helium at potentially leaky parts of the vacuum system, the apparatus can be used with supplemental means to locate leaks.

  17. Robot design for a vacuum environment

    NASA Technical Reports Server (NTRS)

    Belinski, S.; Trento, W.; Imani-Shikhabadi, R.; Hackwood, S.

    1987-01-01

    The cleanliness requirements for many processing and manufacturing tasks are becoming ever stricter, resulting in a greater interest in the vacuum environment. Researchers discuss the importance of this special environment, and the development of robots which are physically and functionally suited to vacuum processing tasks. Work is in progress at the Center for robotic Systems in Microelectronics (CRSM) to provide a robot for the manufacture of a revolutionary new gyroscope in high vacuum. The need for vacuum in this and other processes is discussed as well as the requirements for a vacuum-compatible robot. Finally, researchers present details on work done at the CRSM to modify an existing clean-room compatible robot for use at high vacuum.

  18. Interrupting the balance: reconsidering the complexities of conflict in South Sudan.

    PubMed

    Pendle, Naomi

    2014-04-01

    By the start of 2014, violent conflict had erupted across much of South Sudan following initial violence in Juba on 15 December 2013. The speed with which the fighting has spread raises questions regarding the impact of national-level politics on violence at the local level. This article develops a framework in which violent conflict can be comprehended as a response to the interruption of the negotiation of the balance of power between groups; the negotiation is interrupted when that balance tips in favour of one group, such as through changes in the national political market or government reforms. The article provides two cases studies of attempts to strengthen the state that inadvertently interrupted local power relations between groups. In response, the groups engaged in violent conflict to reinstate a balance of power. Both examples involve conflict among Dinka groups from 2005 to 2008. © 2014 The Author(s). Disasters © Overseas Development Institute, 2014.

  19. Do Work Beliefs Moderate the Relationship Between Work Interruptions, Wellbeing and Psychosomatic Symptoms?

    PubMed Central

    Zoupanou, Zoi(e); Rydstedt, Leif W.

    2017-01-01

    The purpose of this study was to explore the moderating effects of work beliefs in the relationship between work interruptions and general health, wellbeing and reports of psychosomatic symptoms. Self-report data were gathered from 310 employees from different occupational sectors. Results revealed that beliefs in hard work and morality ethic moderated the positive appraisal of work interruptions and acted as protective factors on impaired general health and wellbeing. The relationship was stronger among employees who endorsed strong beliefs in hard work and did not have regard for morality/ethics as a value. Likewise, beliefs in delay of gratification and morality/ethics moderated positive appraisal of work interruptions and reduced psychosomatic complaints. More specifically, the relationship was stronger among employees who had strong belief in the values of delayed gratification and weaker morality/ethics. These findings indicate that organisations should adopt work ideology or practices focused on work values particularly of hard work, delay of gratification and conformity to morality as protective factors that reduce the impact of work interruptions on employees’ general health and wellbeing. PMID:28580023

  20. Nested Interrupt Analysis of Low Cost and High Performance Embedded Systems Using GSPN Framework

    NASA Astrophysics Data System (ADS)

    Lin, Cheng-Min

    Interrupt service routines are a key technology for embedded systems. In this paper, we introduce the standard approach for using Generalized Stochastic Petri Nets (GSPNs) as a high-level model for generating CTMC Continuous-Time Markov Chains (CTMCs) and then use Markov Reward Models (MRMs) to compute the performance for embedded systems. This framework is employed to analyze two embedded controllers with low cost and high performance, ARM7 and Cortex-M3. Cortex-M3 is designed with a tail-chaining mechanism to improve the performance of ARM7 when a nested interrupt occurs on an embedded controller. The Platform Independent Petri net Editor 2 (PIPE2) tool is used to model and evaluate the controllers in terms of power consumption and interrupt overhead performance. Using numerical results, in spite of the power consumption or interrupt overhead, Cortex-M3 performs better than ARM7.

  1. Technical specification for vacuum systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khaw, J.

    The vacuum systems at the Stanford Linear Accelerator Center (SLAC) are primarily of all-metal construction and operate at pressures from 10/sup -5/ to 10/sup -11/ Torr. The primary gas loads during operation result from thermal desorption and beam-induced desorption from the vacuum chamber walls. These desorption rates can be extremely high in the case of hydrocarbons and other contaminants. These specifications place a major emphasis on eliminating contamination sources. The specifications and procedures have been written to insure the cleanliness and vacuum integrity of all SLAC vacuum systems, and to assist personnel involved with SLAC vacuum systems in choosing andmore » designing components that are compatible with existing systems and meet the quality and reliability of SLAC vacuum standards. The specification includes requirements on design, procurement, fabrication, chemical cleaning, clean room practices, welding and brazing, helium leak testing, residual gas analyzer testing, bakeout, venting, and pumpdown. Also appended are specifications regarding acceptable vendors, isopropyl alcohol, bakeable valve cleaning procedure, mechanical engineering safety inspection, notes on synchrotron radiation, and specifications of numerous individual components. (LEW)« less

  2. Interrupting behaviour: Minimizing decision costs via temporal commitment and low-level interrupts.

    PubMed

    Lloyd, Kevin; Dayan, Peter

    2018-01-01

    Ideal decision-makers should constantly assess all sources of information about opportunities and threats, and be able to redetermine their choices promptly in the face of change. However, perpetual monitoring and reassessment impose inordinate sensing and computational costs, making them impractical for animals and machines alike. The obvious alternative of committing for extended periods of time to limited sensory strategies associated with particular courses of action can be dangerous and wasteful. Here, we explore the intermediate possibility of making provisional temporal commitments whilst admitting interruption based on limited broader observation. We simulate foraging under threat of predation to elucidate the benefits of such a scheme. We relate our results to diseases of distractibility and roving attention, and consider mechanistic substrates such as noradrenergic neuromodulation.

  3. Interrupting behaviour: Minimizing decision costs via temporal commitment and low-level interrupts

    PubMed Central

    Dayan, Peter

    2018-01-01

    Ideal decision-makers should constantly assess all sources of information about opportunities and threats, and be able to redetermine their choices promptly in the face of change. However, perpetual monitoring and reassessment impose inordinate sensing and computational costs, making them impractical for animals and machines alike. The obvious alternative of committing for extended periods of time to limited sensory strategies associated with particular courses of action can be dangerous and wasteful. Here, we explore the intermediate possibility of making provisional temporal commitments whilst admitting interruption based on limited broader observation. We simulate foraging under threat of predation to elucidate the benefits of such a scheme. We relate our results to diseases of distractibility and roving attention, and consider mechanistic substrates such as noradrenergic neuromodulation. PMID:29338004

  4. Program Interruptions and Short-Stay Transfers Represent Potential Targets for Inpatient Rehabilitation Care-Improvement Efforts.

    PubMed

    Middleton, Addie; Graham, James E; Krishnan, Shilpa; Ottenbacher, Kenneth J

    2016-11-01

    The objective of this work was to present comprehensive descriptive summaries of program interruptions and short-stay transfers among Medicare fee-for-service beneficiaries receiving inpatient rehabilitation after stroke, traumatic brain injury (TBI), and traumatic spinal cord injury (SCI). Retrospective cohort study of Medicare beneficiaries with any of the 3 conditions of interest who were admitted to inpatient rehabilitation directly from an acute hospital between July 1, 2012, and November 15, 2013. In the final sample (stroke, n = 71 769; TBI, n = 7109; SCI, n = 659), program interruption rates were 0.9% (stroke), 0.8% (TBI), and 1.4% (SCI). Short-stay transfer rates were 22.3% (stroke), 21.8% (TBI), and 31.6% (SCI); 14.7% of short-stay transfers and 12.3% of interruptions resulting in a return to acute care were identified as potentially preventable among those with stroke; 10.2% of transfers and 11.7% of interruptions among those with TBI, and 3.8% of transfers and 11.1% of interruptions among those with SCI. Broad health care policies aimed at improving quality and reducing costs are currently being implemented. Reducing program interruptions and short-stay transfers during inpatient rehabilitative care represents a potential target for care-improvement efforts. Future research focused on identifying modifiable risk factors for potentially undesirable outcomes will allow for targeted preventative interventions.

  5. Program interruptions and short-stay transfers represent potential targets for inpatient rehabilitation care-improvement efforts

    PubMed Central

    Middleton, Addie; Graham, James E.; Krishnan, Shilpa; Ottenbacher, Kenneth J.

    2016-01-01

    Objective To present comprehensive descriptive summaries of program interruptions and short-stay transfers among Medicare fee-for-service beneficiaries receiving inpatient rehabilitation following stroke, traumatic brain injury (TBI), and traumatic spinal cord injury (SCI). Design Retrospective cohort study of Medicare beneficiaries with any of the three conditions of interest who were admitted to inpatient rehabilitation directly from an acute hospital between July 1, 2012 and November 15, 2013. Results In the final sample (stroke: n=71 769; TBI: n=7109; SCI: n=659), program interruption rates were 0.9% (stroke), 0.8% (TBI), and 1.4% (SCI). Short-stay transfer rates were 22.3% (stroke), 21.8% (TBI), and 31.6% (SCI). 14.7% of short-stay transfers and 12.3% of interruptions resulting in a return to acute care were identified as potentially preventable among those with stroke, 10.2% of transfers and 11.7% of interruptions among those with TBI, and 3.8% of transfers and 11.1% of interruptions among those with SCI. Conclusions Broad healthcare policies aimed at improving quality and reducing costs are currently being implemented. Reducing program interruptions and short-stay transfers during inpatient rehabilitative care represents a potential target for care-improvement efforts. Future research focused on identifying modifiable risk factors for potentially undesirable outcomes will allow for targeted preventative interventions. PMID:27631389

  6. 14 CFR 135.417 - Mechanical interruption summary report.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... OPERATING REQUIREMENTS: COMMUTER AND ON DEMAND OPERATIONS AND RULES GOVERNING PERSONS ON BOARD SUCH AIRCRAFT Maintenance, Preventive Maintenance, and Alterations § 135.417 Mechanical interruption summary report. Each... report of the following occurrences in multiengine aircraft for the preceding month to the certificate...

  7. 14 CFR 135.417 - Mechanical interruption summary report.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... OPERATING REQUIREMENTS: COMMUTER AND ON DEMAND OPERATIONS AND RULES GOVERNING PERSONS ON BOARD SUCH AIRCRAFT Maintenance, Preventive Maintenance, and Alterations § 135.417 Mechanical interruption summary report. Each... report of the following occurrences in multiengine aircraft for the preceding month to the certificate...

  8. 14 CFR 135.417 - Mechanical interruption summary report.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... OPERATING REQUIREMENTS: COMMUTER AND ON DEMAND OPERATIONS AND RULES GOVERNING PERSONS ON BOARD SUCH AIRCRAFT Maintenance, Preventive Maintenance, and Alterations § 135.417 Mechanical interruption summary report. Each... report of the following occurrences in multiengine aircraft for the preceding month to the certificate...

  9. 14 CFR 135.417 - Mechanical interruption summary report.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... OPERATING REQUIREMENTS: COMMUTER AND ON DEMAND OPERATIONS AND RULES GOVERNING PERSONS ON BOARD SUCH AIRCRAFT Maintenance, Preventive Maintenance, and Alterations § 135.417 Mechanical interruption summary report. Each... report of the following occurrences in multiengine aircraft for the preceding month to the certificate...

  10. Bakeout Chamber Within Vacuum Chamber

    NASA Technical Reports Server (NTRS)

    Taylor, Daniel M.; Soules, David M.; Barengoltz, Jack B.

    1995-01-01

    Vacuum-bakeout apparatus for decontaminating and measuring outgassing from pieces of equipment constructed by mounting bakeout chamber within conventional vacuum chamber. Upgrade cost effective: fabrication and installation of bakeout chamber simple, installation performed quickly and without major changes in older vacuum chamber, and provides quantitative data on outgassing from pieces of equipment placed in bakeout chamber.

  11. Interrupted time series analysis in drug utilization research is increasing: systematic review and recommendations.

    PubMed

    Jandoc, Racquel; Burden, Andrea M; Mamdani, Muhammad; Lévesque, Linda E; Cadarette, Suzanne M

    2015-08-01

    To describe the use and reporting of interrupted time series methods in drug utilization research. We completed a systematic search of MEDLINE, Web of Science, and reference lists to identify English language articles through to December 2013 that used interrupted time series methods in drug utilization research. We tabulated the number of studies by publication year and summarized methodological detail. We identified 220 eligible empirical applications since 1984. Only 17 (8%) were published before 2000, and 90 (41%) were published since 2010. Segmented regression was the most commonly applied interrupted time series method (67%). Most studies assessed drug policy changes (51%, n = 112); 22% (n = 48) examined the impact of new evidence, 18% (n = 39) examined safety advisories, and 16% (n = 35) examined quality improvement interventions. Autocorrelation was considered in 66% of studies, 31% reported adjusting for seasonality, and 15% accounted for nonstationarity. Use of interrupted time series methods in drug utilization research has increased, particularly in recent years. Despite methodological recommendations, there is large variation in reporting of analytic methods. Developing methodological and reporting standards for interrupted time series analysis is important to improve its application in drug utilization research, and we provide recommendations for consideration. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  12. Interrupted intracarotid artery cold saline infusion as an alternative method for neuroprotection after ischemic stroke.

    PubMed

    Ji, Ya-Bin; Wu, Yong-Ming; Ji, Zhong; Song, Wei; Xu, Sui-Yi; Wang, Yao; Pan, Su-Yue

    2012-07-01

    Intracarotid artery cold saline infusion (ICSI) is an effective method for protecting brain tissue, but its use is limited because of undesirable secondary effects, such as severe decreases in hematocrit levels, as well as its relatively brief duration. In this study, the authors describe and investigate the effects of a novel ICSI pattern (interrupted ICSI) relative to the traditional method (uninterrupted ICSI). Ischemic strokes were induced in 85 male Sprague-Dawley rats by occluding the middle cerebral artery for 3 hours using an intraluminal filament. Uninterrupted infusion groups received an infusion at 15 ml/hour for 30 minutes continuously. The same infusion speed was used in the interrupted infusion groups, but the whole duration was divided into trisections, and there was a 20-minute interval without infusion between sections. Forty-eight hours after reperfusion, H & E and silver nitrate staining were utilized for morphological assessment. Infarct sizes and brain water contents were determined using H & E staining and the dry-wet weight method, respectively. Levels of neuron-specific enolase (NSE), S100β protein, and matrix metalloproteinase 9 (MMP-9) in the serum were determined using enzyme-linked immunosorbent assay. Neurological deficits were also evaluated. Histology showed that interrupted ICSI did not affect neurons or fibers in rat brains, which suggests that this method is safe for brain tissues with ischemia. The duration of hypothermia induced by interrupted ICSI was longer than that induced via the traditional method, and the decrease in hematocrit levels was less pronounced. There were no differences in infarct size or brain water content between uninterrupted and interrupted ICSI groups, but neuron-specific enolase and matrix metalloproteinase 9 serum levels were more reduced after interrupted ICSI than after the traditional method. Interrupted ICSI is a safe method. Compared with traditional ICSI, the interrupted method has a longer

  13. Are Technology Interruptions Impacting Your Bottom Line? An Innovative Proposal for Change.

    PubMed

    Ledbetter, Tamera; Shultz, Sarah; Beckham, Roxanne

    2017-10-01

    Nursing interruptions are a costly and dangerous variable in acute care hospitals. Malfunctioning technology equipment interrupts nursing care and prevents full utilization of computer safety systems to prevent patient care errors. This paper identifies an innovative approach to nursing interruptions related to computer and computer cart malfunctions. The impact on human resources is defined and outcome measures were proposed. A multifaceted proposal, based on a literature review, aimed at reducing nursing interruptions is presented. This proposal is expected to increase patient safety, as well as patient and nurse satisfaction. Acute care hospitals utilizing electronic medical records and bar-coded medication administration technology. Nurses, information technology staff, nursing informatics staff, and all leadership teams affected by technology problems and their proposed solutions. Literature from multiple fields was reviewed to evaluate research related to computer/computer cart failures, and the approaches used to resolve these issues. Outcome measured strategic goals related to patient safety, and nurse and patient satisfaction. Specific help desk metrics will demonstrate the effect of interventions. This paper addresses a gap in the literature and proposes practical and innovative solutions. A comprehensive computer and computer cart repair program is essential for patient safety, financial stewardship, and utilization of resources. © 2015 Wiley Periodicals, Inc.

  14. Interrupted reperfusion reduces the activation of NADPH oxidase after cerebral I/R injury.

    PubMed

    Shen, Jia; Bai, Xiao-Yin; Qin, Yuan; Jin, Wei-Wei; Zhou, Jing-Yin; Zhou, Ji-Ping; Yan, Ying-Gang; Wang, Qiong; Bruce, Iain C; Chen, Jiang-Hua; Xia, Qiang

    2011-06-15

    Interrupted reperfusion reduces ischemia/reperfusion (I/R) injury. This study was designed to determine whether NADPH oxidase participates in the neural protection against global I/R injury after interrupted reperfusion. Mice were randomly divided into five groups: sham (sham-operated), I/R (20-min global I/R), RR (I/R+interrupted reperfusion), Apo (I/R+apocynin administration), and RR+Apo. Behavioral tests (pole test, beam walking, and Morris water maze) and Nissl staining were undertaken in all five groups; superoxide levels, expression of gp91(phox) and p47(phox), p47(phox) translocation, and Rac1 activation were measured in the sham, I/R, and RR groups. The motor coordination, bradykinesia, and spatial learning and memory, as well as the neuron survival rates, were better in the RR, Apo, and RR+Apo groups than in the I/R group. The NADPH oxidase-dependent superoxide levels, p47(phox) and gp91(phox) expression, p47(phox) translocation, and Rac1 activation were lower in the RR group than in the I/R group. In conclusion, the neural protective effect of interrupted reperfusion is at least partly mediated by decreasing the expression and assembly of NADPH oxidase and the levels of NADPH oxidase-derived superoxide. The most striking reduction Rac1-GTP in the RR group suggests that interrupted reperfusion also acts on the activation of assembled NADPH oxidase by reducing the availability of Rac1-GTP. Copyright © 2011 Elsevier Inc. All rights reserved.

  15. Self-interrupted synthesis of sterically hindered aliphatic polyamide dendrimers

    PubMed Central

    Jishkariani, Davit; Timsina, Yam N.; Grama, Silvia; Gillani, Syeda S.; Divar, Masoumeh; Yadavalli, Srujana S.; Moussodia, Ralph-Olivier; Leowanawat, Pawaret; Berrios Camacho, Angely M.; Walter, Ricardo; Goulian, Mark; Klein, Michael L.; Percec, Virgil

    2017-01-01

    2,2-Bis(azidomethyl)propionic acid was prepared in four steps and 85% yield from the commercially available 2,2-bis(hydroxymethyl)propionic acid and used as the starting building block for the divergent, convergent, and double-stage convergent–divergent iterative methods for the synthesis of dendrimers and dendrons containing ethylenediamine (EDA), piperazine (PPZ), and methyl 2,2-bis(aminomethyl)propionate (COOMe) cores. These cores have the same multiplicity but different conformations. A diversity of synthetic methods were used for the synthesis of dendrimers and dendrons. Regardless of the method used, a self-interruption of the synthesis was observed at generation 4 for the dendrimer with an EDA core and at generation 5 for the one with a PPZ core, whereas for the COOMe core, self-interruption was observed at generation 6 dendron, which is equivalent to generation 5 dendrimer. Molecular modeling and molecular-dynamics simulations demonstrated that the observed self-interruption is determined by the backfolding of the azide groups at the periphery of the dendrimer. The latter conformation inhibits completely the heterogeneous hydrogenation of the azide groups catalyzed by 10% Pd/carbon as well as homogeneous hydrogenation by the Staudinger method. These self-terminated polyamide dendrimers are enzymatically and hydrolytically stable and also exhibit antimicrobial activity. Thus, these nanoscale constructs open avenues for biomedical applications. PMID:28270599

  16. 38 CFR 21.5078 - Interruption to conserve entitlement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2011-07-01 2011-07-01 false Interruption to conserve entitlement. 21.5078 Section 21.5078 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS (CONTINUED) VOCATIONAL REHABILITATION AND EDUCATION Post-Vietnam Era Veterans' Educational Assistance Under...

  17. 38 CFR 21.5078 - Interruption to conserve entitlement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2012-07-01 2012-07-01 false Interruption to conserve entitlement. 21.5078 Section 21.5078 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS (CONTINUED) VOCATIONAL REHABILITATION AND EDUCATION Post-Vietnam Era Veterans' Educational Assistance Under...

  18. 38 CFR 21.5078 - Interruption to conserve entitlement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2013-07-01 2013-07-01 false Interruption to conserve entitlement. 21.5078 Section 21.5078 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS (CONTINUED) VOCATIONAL REHABILITATION AND EDUCATION Post-Vietnam Era Veterans' Educational Assistance Under...

  19. 38 CFR 21.5078 - Interruption to conserve entitlement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2014-07-01 2014-07-01 false Interruption to conserve entitlement. 21.5078 Section 21.5078 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS (CONTINUED) VOCATIONAL REHABILITATION AND EDUCATION Post-Vietnam Era Veterans' Educational Assistance Under...

  20. 38 CFR 21.5078 - Interruption to conserve entitlement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Interruption to conserve entitlement. 21.5078 Section 21.5078 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS (CONTINUED) VOCATIONAL REHABILITATION AND EDUCATION Post-Vietnam Era Veterans' Educational Assistance Under...

  1. Development of a High-speed Electromagnetic Repulsion Mechanism for High-voltage Vacuum Circuit Breakers

    NASA Astrophysics Data System (ADS)

    Tsukima, Mitsuru; Takeuchi, Toshie; Koyama, Kenichi; Yoshiyasu, Hajimu

    This paper presents a design and testing of a new high-speed electromagnetic driving mechanism for a high-voltage vacuum circuit breaker (VCB). This mechanism is based on a high-speed electromagnetic repulsion and a permanent magnet spring (PMS). This PMS is introduced instead of the conventional disk spring due to its low spring energy and more suitable force characteristics for VCB application. The PMS has been optimally designed by the 3d non-linear finite-elements magnetic field analysis and investigated its internal friction and eddy-current effect. Furthermore, we calculated the dynamic of this mechanism coupling with the electromagnetic field and circuit analysis, in order to satisfy the operating characteristics—contact velocity, response time and so on, required for the high-speed VCB. A prototype VCB, which was built based on the above analysis shows sufficient operating performance. Finally, the short circuit interruption tests were carried out with this prototype breaker, and we have been able to verify its satisfying performance.

  2. Characteristics of GeV Electron Bunches Accelerated by Intense Lasers in Vacuum

    NASA Astrophysics Data System (ADS)

    Wang, P. X.; Ho, Y. K.; Kong, Q.; Yuan, X. Q.; Cao, N.; Feng, L.

    This paper studies the characteristics of GeV electron bunches driven by ultra-intense lasers in vacuum based on the mechanism of capture and violent acceleration scenario [CAS, see, e.g. J. X. Wang et al., Phys. Rev. E58, 6575 (1998)], which shows an interesting prospect of becoming a new principle of laser-driven accelerators. It has been found that the accelerated GeV electron bunch is a macro-pulse composed of a lot of micro-pulses, which is analogous to the structure of the bunches produced by conventional linacs. The macro-pulse corresponds to the duration of the laser pulse while the micro-pulse corresponds to the periodicity of the laser wave. Therefore, provided that the incoming electron bunch with comparable sizes as that of the laser pulse synchronously impinges on the laser pulse, the total fraction of electrons captured and accelerated to GeV energy can reach more than 20%. These results demonstrate that the mechanisms of CAS is a relatively effective accelerator mechanism.

  3. Improving Vacuum Cleaners

    NASA Technical Reports Server (NTRS)

    1997-01-01

    Under a Space Act Agreement between the Kirby company and Lewis Research Center, NASA technology was applied to a commercial vacuum cleaner product line. Kirby engineers were interested in advanced operational concepts, such as particle flow behavior and vibration, critical factors to improve vacuum cleaner performance. An evaluation of the company 1994 home care system, the Kirby G4, led to the refinement of the new G5 and future models. Under the cooperative agreement, Kirby had access to Lewis' holography equipment, which added insight into how long a vacuum cleaner fan would perform, as well as advanced computer software that can simulate the flow of air through fans. The collaboration resulted in several successes including fan blade redesign and continuing dialogue on how to improve air-flow traits in various nozzle designs.

  4. Separate Medication Preparation Rooms Reduce Interruptions and Medication Errors in the Hospital Setting: A Prospective Observational Study.

    PubMed

    Huckels-Baumgart, Saskia; Baumgart, André; Buschmann, Ute; Schüpfer, Guido; Manser, Tanja

    2016-12-21

    Interruptions and errors during the medication process are common, but published literature shows no evidence supporting whether separate medication rooms are an effective single intervention in reducing interruptions and errors during medication preparation in hospitals. We tested the hypothesis that the rate of interruptions and reported medication errors would decrease as a result of the introduction of separate medication rooms. Our aim was to evaluate the effect of separate medication rooms on interruptions during medication preparation and on self-reported medication error rates. We performed a preintervention and postintervention study using direct structured observation of nurses during medication preparation and daily structured medication error self-reporting of nurses by questionnaires in 2 wards at a major teaching hospital in Switzerland. A volunteer sample of 42 nurses was observed preparing 1498 medications for 366 patients over 17 hours preintervention and postintervention on both wards. During 122 days, nurses completed 694 reporting sheets containing 208 medication errors. After the introduction of the separate medication room, the mean interruption rate decreased significantly from 51.8 to 30 interruptions per hour (P < 0.01), and the interruption-free preparation time increased significantly from 1.4 to 2.5 minutes (P < 0.05). Overall, the mean medication error rate per day was also significantly reduced after implementation of the separate medication room from 1.3 to 0.9 errors per day (P < 0.05). The present study showed the positive effect of a hospital-based intervention; after the introduction of the separate medication room, the interruption and medication error rates decreased significantly.

  5. Trial of Continuous or Interrupted Chest Compressions during CPR.

    PubMed

    Nichol, Graham; Leroux, Brian; Wang, Henry; Callaway, Clifton W; Sopko, George; Weisfeldt, Myron; Stiell, Ian; Morrison, Laurie J; Aufderheide, Tom P; Cheskes, Sheldon; Christenson, Jim; Kudenchuk, Peter; Vaillancourt, Christian; Rea, Thomas D; Idris, Ahamed H; Colella, Riccardo; Isaacs, Marshal; Straight, Ron; Stephens, Shannon; Richardson, Joe; Condle, Joe; Schmicker, Robert H; Egan, Debra; May, Susanne; Ornato, Joseph P

    2015-12-03

    During cardiopulmonary resuscitation (CPR) in patients with out-of-hospital cardiac arrest, the interruption of manual chest compressions for rescue breathing reduces blood flow and possibly survival. We assessed whether outcomes after continuous compressions with positive-pressure ventilation differed from those after compressions that were interrupted for ventilations at a ratio of 30 compressions to two ventilations. This cluster-randomized trial with crossover included 114 emergency medical service (EMS) agencies. Adults with non-trauma-related cardiac arrest who were treated by EMS providers received continuous chest compressions (intervention group) or interrupted chest compressions (control group). The primary outcome was the rate of survival to hospital discharge. Secondary outcomes included the modified Rankin scale score (on a scale from 0 to 6, with a score of ≤3 indicating favorable neurologic function). CPR process was measured to assess compliance. Of 23,711 patients included in the primary analysis, 12,653 were assigned to the intervention group and 11,058 to the control group. A total of 1129 of 12,613 patients with available data (9.0%) in the intervention group and 1072 of 11,035 with available data (9.7%) in the control group survived until discharge (difference, -0.7 percentage points; 95% confidence interval [CI], -1.5 to 0.1; P=0.07); 7.0% of the patients in the intervention group and 7.7% of those in the control group survived with favorable neurologic function at discharge (difference, -0.6 percentage points; 95% CI, -1.4 to 0.1, P=0.09). Hospital-free survival was significantly shorter in the intervention group than in the control group (mean difference, -0.2 days; 95% CI, -0.3 to -0.1; P=0.004). In patients with out-of-hospital cardiac arrest, continuous chest compressions during CPR performed by EMS providers did not result in significantly higher rates of survival or favorable neurologic function than did interrupted chest compressions

  6. The expansion of polarization charge layers into magnetized vacuum - Theory and computer simulations

    NASA Technical Reports Server (NTRS)

    Galvez, Miguel; Borovsky, Joseph E.

    1991-01-01

    The formation and evolution of polarization charge layers on cylindrical plasma streams moving in vacuum are investigated using analytic theory and 2D electrostatic particle-in-cell computer simulations. It is shown that the behavior of the electron charge layer goes through three stages. An early time expansion is driven by electrostatic repulsion of electrons in the charge layer. At the intermediate stage, the simulations show that the electron-charge-layer expansion is halted by the positively charged plasma stream. Electrons close to the stream are pulled back to the stream and a second electron expansion follows in time. At the late stage, the expansion of the ion charge layer along the magnetic field lines accompanies the electron expansion to form an ambipolar expansion. It is found that the velocities of these electron-ion expansions greatly exceed the velocities of ambipolar expansions which are driven by plasma temperatures.

  7. Evaluation of nano- and submicron particle penetration through ten nonwoven fabrics using a wind-driven approach.

    PubMed

    Gao, Pengfei; Jaques, Peter A; Hsiao, Ta-Chih; Shepherd, Angie; Eimer, Benjamin C; Yang, Mengshi; Miller, Adam; Gupta, Bhupender; Shaffer, Ronald

    2011-01-01

    Existing face mask and respirator test methods draw particles through materials under vacuum to measure particle penetration. However, these filtration-based methods may not simulate conditions under which protective clothing operates in the workplace, where airborne particles are primarily driven by wind and other factors instead of being limited to a downstream vacuum. This study was focused on the design and characterization of a method simulating typical wind-driven conditions for evaluating the performance of materials used in the construction of protective clothing. Ten nonwoven fabrics were selected, and physical properties including fiber diameter, fabric thickness, air permeability, porosity, pore volume, and pore size were determined. Each fabric was sealed flat across the wide opening of a cone-shaped penetration cell that was then housed in a recirculation aerosol wind tunnel. The flow rate naturally driven by wind through the fabric was measured, and the sampling flow rate of the Scanning Mobility Particle Sizer used to measure the downstream particle size distribution and concentrations was then adjusted to minimize filtration effects. Particle penetration levels were measured under different face velocities by the wind-driven method and compared with a filtration-based method using the TSI 3160 automated filter tester. The experimental results show that particle penetration increased with increasing face velocity, and penetration also increased with increasing particle size up to about 300 to 500 nm. Penetrations measured by the wind-driven method were lower than those obtained with the filtration method for most of the fabrics selected, and the relative penetration performances of the fabrics were very different due to the vastly different pore structures.

  8. 14 CFR 121.705 - Mechanical interruption summary report.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Mechanical interruption summary report. 121... OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Records and Reports § 121.705 Mechanical... known or suspected mechanical difficulties or malfunctions that are not required to be reported under...

  9. Prediction of SFL Interruption Performance from the Results of Arc Simulation during High-Current Phase

    NASA Astrophysics Data System (ADS)

    Lee, Jong-Chul; Lee, Won-Ho; Kim, Woun-Jea

    2015-09-01

    The design and development procedures of SF6 gas circuit breakers are still largely based on trial and error through testing although the development costs go higher every year. The computation cannot cover the testing satisfactorily because all the real processes arc not taken into account. But the knowledge of the arc behavior and the prediction of the thermal-flow inside the interrupters by numerical simulations are more useful than those by experiments due to the difficulties to obtain physical quantities experimentally and the reduction of computational costs in recent years. In this paper, in order to get further information into the interruption process of a SF6 self-blast interrupter, which is based on a combination of thermal expansion and the arc rotation principle, gas flow simulations with a CFD-arc modeling are performed during the whole switching process such as high-current period, pre-current zero period, and current-zero period. Through the complete work, the pressure-rise and the ramp of the pressure inside the chamber before current zero as well as the post-arc current after current zero should be a good criterion to predict the short-line fault interruption performance of interrupters.

  10. Switching Circuit for Shop Vacuum System

    NASA Technical Reports Server (NTRS)

    Burley, R. K.

    1987-01-01

    No internal connections to machine tools required. Switching circuit controls vacuum system draws debris from grinders and sanders in machine shop. Circuit automatically turns on vacuum system whenever at least one sander or grinder operating. Debris safely removed, even when operator neglects to turn on vacuum system manually. Pickup coils sense alternating magnetic fields just outside operating machines. Signal from any coil or combination of coils causes vacuum system to be turned on.

  11. Vacuum Brazing of Accelerator Components

    NASA Astrophysics Data System (ADS)

    Singh, Rajvir; Pant, K. K.; Lal, Shankar; Yadav, D. P.; Garg, S. R.; Raghuvanshi, V. K.; Mundra, G.

    2012-11-01

    Commonly used materials for accelerator components are those which are vacuum compatible and thermally conductive. Stainless steel, aluminum and copper are common among them. Stainless steel is a poor heat conductor and not very common in use where good thermal conductivity is required. Aluminum and copper and their alloys meet the above requirements and are frequently used for the above purpose. The accelerator components made of aluminum and its alloys using welding process have become a common practice now a days. It is mandatory to use copper and its other grades in RF devices required for accelerators. Beam line and Front End components of the accelerators are fabricated from stainless steel and OFHC copper. Fabrication of components made of copper using welding process is very difficult and in most of the cases it is impossible. Fabrication and joining in such cases is possible using brazing process especially under vacuum and inert gas atmosphere. Several accelerator components have been vacuum brazed for Indus projects at Raja Ramanna Centre for Advanced Technology (RRCAT), Indore using vacuum brazing facility available at RRCAT, Indore. This paper presents details regarding development of the above mentioned high value and strategic components/assemblies. It will include basics required for vacuum brazing, details of vacuum brazing facility, joint design, fixturing of the jobs, selection of filler alloys, optimization of brazing parameters so as to obtain high quality brazed joints, brief description of vacuum brazed accelerator components etc.

  12. Causal Inference and the Comparative Interrupted Time Series Design: Findings from Within-Study Comparisons

    ERIC Educational Resources Information Center

    St. Clair, Travis; Hallberg, Kelly; Cook, Thomas D.

    2014-01-01

    Researchers are increasingly using comparative interrupted time series (CITS) designs to estimate the effects of programs and policies when randomized controlled trials are not feasible. In a simple interrupted time series design, researchers compare the pre-treatment values of a treatment group time series to post-treatment values in order to…

  13. Accommodating interruptions: A grounded theory of young people with asthma.

    PubMed

    Hughes, Mary; Savage, Eileen; Andrews, Tom

    2018-01-01

    The aim of this study was to develop an explanatory theory on the lives of young people with asthma, issues affecting them and the impact of asthma on their day-to-day lives. Accommodating Interruptions is a theory that explains young people's concerns about living with asthma. Although national and international asthma management guidelines exist, it is accepted that the symptom control of asthma among the young people population is poor. This study was undertaken using Classic Grounded Theory. Data were collected through in-depth interviews and clinic consultations with young people aged 11-16 years who had asthma for over 1 year. Data were also collected from participant diaries. Constant comparative analysis, theoretical coding and memo writing were used to develop the substantive theory. The theory explains how young people resolve their main concern of being restricted by Accommodating Interruptions in their lives. They do this by assimilating behaviours in balance finding, moderating influence, fitting in and assuming control minimising the effects of asthma on their everyday lives. The theory of Accommodating Interruptions explains young people's asthma management behaviours in a new way. It allows us to understand how and why young people behave the way they do because they want to participate and be included in everyday activities, events and relationships. The theory adds to the body of knowledge on how young people with asthma live their day-to-day lives and it challenges some existing viewpoints in the literature regarding their behaviours. The findings have implications for developing services to support young people in a more meaningful way as they accommodate the interruptions associated with asthma in their lives. © 2017 John Wiley & Sons Ltd.

  14. Differentiating between adductor and abductor spasmodic dysphonia using airflow interruption

    PubMed Central

    Hoffman, Matthew R.; Jiang, Jack J.; Rieves, Adam L.; McElveen, Kelsey A.B.; Ford, Charles N.

    2009-01-01

    Objective To measure the laryngeal resistance (RL), subglottal pressure (Ps), and mean flow rate (MFR) of adductor (ADSD) and abductor (ABSD) spasmodic dysphonia patients using the airflow interrupter. Methods The RL of six ABSD and seven ADSD patients was measured using the airflow interrupter, a noninvasive device designed to measure MFR and Ps via mechanical balloon valve interruption. Subjects performed ten trials at each of two intensity levels, with each trial consisting of a sustained /a/ during which phonation was interrupted for 500 ms. Laryngeal resistance was calculated as subglottal pressure divided by airflow. Results Mean RL for the ADSD and ABSD subtypes at 65 dB were 24.78 cmH2O/l/s and 14.51 cmH2O/l/s, respectively (p = 0.04). Mean RL at 70 dB were 40.02 cmH2O/l/s and 15.84 cmH2O/l/s (p = 0.014). Ps for the ADSD and ABSD subtypes at 65 dB were 10.23 cmH2O and 8.32 cmH2O, respectively (p = 0.582). At the 70 dB level, Ps were 12.39 cmH2O and 11.78 cmH2O (p = 0.886). MFR for the ADSD and ABSD subtypes at 65 dB were 435 ml/s and 746 ml/s (p = 0.205). Mean MFR at 70 dB were 518 ml/s and 848 ml/s (p = 0.198). Conclusion Noninvasive measurements of RL may be useful for differentiating between ADSD and ABSD. This simple objective test which produces a quantitative output could be used to evaluate laryngeal function in patients with spasmodic dysphonia. PMID:19554636

  15. Vacuum-insulated catalytic converter

    DOEpatents

    Benson, David K.

    2001-01-01

    A catalytic converter has an inner canister that contains catalyst-coated substrates and an outer canister that encloses an annular, variable vacuum insulation chamber surrounding the inner canister. An annular tank containing phase-change material for heat storage and release is positioned in the variable vacuum insulation chamber a distance spaced part from the inner canister. A reversible hydrogen getter in the variable vacuum insulation chamber, preferably on a surface of the heat storage tank, releases hydrogen into the variable vacuum insulation chamber to conduct heat when the phase-change material is hot and absorbs the hydrogen to limit heat transfer to radiation when the phase-change material is cool. A porous zeolite trap in the inner canister absorbs and retains hydrocarbons from the exhaust gases when the catalyst-coated substrates and zeolite trap are cold and releases the hydrocarbons for reaction on the catalyst-coated substrate when the zeolite trap and catalyst-coated substrate get hot.

  16. Vacuum-Induction, Vacuum-Arc, and Air-Induction Melting of a Complex Heat-Resistant Alloy

    NASA Technical Reports Server (NTRS)

    Decker, R. F.; Rowe, John P.; Freeman, J. W.

    1959-01-01

    The relative hot-workability and creep-rupture properties at 1600 F of a complex 55Ni-20Cr-15Co-4Mo-3Ti-3Al alloy were evaluated for vacuum-induction, vacuum-arc, and air-induction melting. A limited study of the role of oxygen and nitrogen and the structural effects in the alloy associated with the melting process was carried out. The results showed that the level of boron and/or zirconium was far more influential on properties than the melting method. Vacuum melting did reduce corner cracking and improve surface during hot-rolling. It also resulted in more uniform properties within heats. The creep-rupture properties were slightly superior in vacuum heats at low boron plus zirconium or in heats with zirconium. There was little advantage at high boron levels and air heats were superior at high levels of boron plus zirconium. Vacuum heats also had fewer oxide and carbonitride inclusions although this was a function of the opportunity for separation of the inclusions from high oxygen plus nitrogen heats. The removal of phosphorous by vacuum melting was not found to be related to properties. Oxygen plus nitrogen appeared to increase ductility in creep-rupture tests suggesting that vacuum melting removes unidentified elements detrimental to ductility. Oxides and carbonitrides in themselves did not initiate microcracks. Carbonitrides in the grain boundaries of air heats did initiate microcracks. The role of microcracking from this source and as a function of oxygen and nitrogen content was not clear. Oxygen and nitrogen did intensify corner cracking during hot-rolling but were not responsible for poor surface which resulted from rolling heats melted in air.

  17. Comparison of the adsorbed conformation of barley lipid transfer protein at the decane-water and vacuum-water interface: a molecular dynamics simulation.

    PubMed

    Euston, S R; Hughes, P; Naser, Md A; Westacott, R E

    2008-05-01

    Molecular dynamics simulation is used to model the adsorption of the barley lipid transfer protein (LTP) at the decane-water and vacuum-water interfaces. Adsorption at both surfaces is driven by displacement of water molecules from the interfacial region. LTP adsorbed at the decane surface exhibits significant changes in its tertiary structure, and penetrates a considerable distance into the decane phase. At the vacuum-water interface LTP shows small conformational changes away from its native structure and does not penetrate into the vacuum space. Modification of the conformational stability of LTP by reduction of its four disulphide bonds leads to an increase in conformational entropy of the molecules, which reduces the driving force for adsorption. Evidence for changes in the secondary structure are also observed for native LTP at the decane-water interface and reduced LTP at the vacuum-water interface. In particular, intermittent formation of short (six-residue) regions of beta-sheet is found in these two systems. Formation of interfacial beta-sheet in adsorbed proteins has been observed experimentally, notably in the globular milk protein beta-lactoglobulin and lysozyme.

  18. Wireless Integrated Microelectronic Vacuum Sensor System

    NASA Technical Reports Server (NTRS)

    Krug, Eric; Philpot, Brian; Trott, Aaron; Lawrence, Shaun

    2013-01-01

    NASA Stennis Space Center's (SSC's) large rocket engine test facility requires the use of liquid propellants, including the use of cryogenic fluids like liquid hydrogen as fuel, and liquid oxygen as an oxidizer (gases which have been liquefied at very low temperatures). These fluids require special handling, storage, and transfer technology. The biggest problem associated with transferring cryogenic liquids is product loss due to heat transfer. Vacuum jacketed piping is specifically designed to maintain high thermal efficiency so that cryogenic liquids can be transferred with minimal heat transfer. A vacuum jacketed pipe is essentially two pipes in one. There is an inner carrier pipe, in which the cryogenic liquid is actually transferred, and an outer jacket pipe that supports and seals the vacuum insulation, forming the "vacuum jacket." The integrity of the vacuum jacketed transmission lines that transfer the cryogenic fluid from delivery barges to the test stand must be maintained prior to and during engine testing. To monitor the vacuum in these vacuum jacketed transmission lines, vacuum gauge readings are used. At SSC, vacuum gauge measurements are done on a manual rotation basis with two technicians, each using a handheld instrument. Manual collection of vacuum data is labor intensive and uses valuable personnel time. Additionally, there are times when personnel cannot collect the data in a timely fashion (i.e., when a leak is detected, measurements must be taken more often). Additionally, distribution of this data to all interested parties can be cumbersome. To simplify the vacuum-gauge data collection process, automate the data collection, and decrease the labor costs associated with acquiring these measurements, an automated system that monitors the existing gauges was developed by Invocon, Inc. For this project, Invocon developed a Wireless Integrated Microelectronic Vacuum Sensor System (WIMVSS) that provides the ability to gather vacuum

  19. Deleterious effects of interruption followed by reintroduction of enzyme replacement therapy on a lysosomal storage disorder.

    PubMed

    Schneider, Ana Paula; Matte, Ursula; Pasqualim, Gabriela; Tavares, Angela Maria Vicente; Mayer, Fabiana Quoos; Martinelli, Barbara; Ribas, Graziela; Vargas, Carmen Regla; Giugliani, Roberto; Baldo, Guilherme

    2016-10-01

    Temporary interruption of enzyme replacement therapy (ERT) in patients with different lysosomal storage disorders may happen for different reasons (adverse reactions, issues with reimbursement, logistic difficulties, and so forth), and the impact of the interruption is still uncertain. In the present work, we studied the effects of the interruption of intravenous ERT (Laronidase, Genzyme) followed by its reintroduction in mice with the prototypical lysosomal storage disorder mucopolysaccharidosis type I, comparing to mice receiving continuous treatment, untreated mucopolysaccharidosis type I mice, and normal mice. In the animals which treatment was temporarily interrupted, we observed clear benefits of treatment in several organs (liver, lung, heart, kidney, and testis) after reintroduction, but a worsening in the thickness of the aortic wall was detected. Furthermore, these mice had just partial improvements in behavioral tests, suggesting some deterioration in the brain function. Despite worsening is some disease aspects, urinary glycosaminoglycans levels did not increase during interruption, which indicates that this biomarker commonly used to monitor treatment in patients should not be used alone to assess treatment efficacy. The deterioration observed was not caused by the development of serum antienzyme antibodies. All together our results suggest that temporary ERT interruption leads to deterioration of function in some organs and should be avoided whenever possible. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Distinct mechanisms for the impact of distraction and interruption on working memory in aging

    PubMed Central

    Clapp, Wesley C; Gazzaley, Adam

    2010-01-01

    Interference is known to negatively impact the ability to maintain information in working memory (WM), an effect that is exacerbated with aging. Here, we explore how distinct sources of interference, i.e., distraction (stimuli to-be-ignored) and interruption (stimuli requiring attention), differentially influence WM in younger and older adults. EEG was recorded while participants engaged in three versions of a delayed-recognition task: no interference, a distracting stimulus, and an interrupting stimulus presented during WM maintenance. Behaviorally, both types of interference negatively impacted WM accuracy in older adults significantly more than younger adults (with a larger deficit for interruptions). N170 latency measures revealed that the degree of processing both distractors and interruptors predicted WM accuracy in both populations. However, while WM impairments could be explained by excessive attention to distractors by older adults (a suppression deficit), impairment induced by interruption were not clearly mediated by age-related increases in attention to interruptors. These results suggest that distinct underlying mechanisms mediate the impact of different types of external interference on WM in normal aging. PMID:20144492

  1. Running vacuum cosmological models: linear scalar perturbations

    NASA Astrophysics Data System (ADS)

    Perico, E. L. D.; Tamayo, D. A.

    2017-08-01

    In cosmology, phenomenologically motivated expressions for running vacuum are commonly parameterized as linear functions typically denoted by Λ(H2) or Λ(R). Such models assume an equation of state for the vacuum given by bar PΛ = - bar rhoΛ, relating its background pressure bar PΛ with its mean energy density bar rhoΛ ≡ Λ/8πG. This equation of state suggests that the vacuum dynamics is due to an interaction with the matter content of the universe. Most of the approaches studying the observational impact of these models only consider the interaction between the vacuum and the transient dominant matter component of the universe. We extend such models by assuming that the running vacuum is the sum of independent contributions, namely bar rhoΛ = Σibar rhoΛi. Each Λ i vacuum component is associated and interacting with one of the i matter components in both the background and perturbation levels. We derive the evolution equations for the linear scalar vacuum and matter perturbations in those two scenarios, and identify the running vacuum imprints on the cosmic microwave background anisotropies as well as on the matter power spectrum. In the Λ(H2) scenario the vacuum is coupled with every matter component, whereas the Λ(R) description only leads to a coupling between vacuum and non-relativistic matter, producing different effects on the matter power spectrum.

  2. Mediated interruptions of anaesthesia providers using predictions of workload from anaesthesia information management system data.

    PubMed

    Epstein, R H; Dexter, F

    2012-09-01

    Perioperative interruptions generated electronically from anaesthesia information management systems (AIMS) can provide useful feedback, but may adversely affect task performance if distractions occur at inopportune moments. Ideally such interruptions would occur only at times when their impact would be minimal. In this study of AIMS data, we evaluated the times of comments, drugs, fluids and periodic assessments (e.g. electrocardiogram diagnosis and train-of-four) to develop recommendations for the timing of interruptions during the intraoperative period. The 39,707 cases studied were divided into intervals between: 1) enter operating room; 2) induction; 3) intubation; 4) surgical incision; and 5) end surgery. Five-minute intervals of no documentation were determined for each case. The offsets from the start of each interval when >50% of ongoing cases had completed initial documentation were calculated (MIN50). The primary endpoint for each interval was the percentage of all cases still ongoing at MIN50. Results were that the intervals from entering the operating room to induction and from induction to intubation were unsuitable for interruptions confirming prior observational studies of anaesthesia workload. At least 13 minutes after surgical incision was the most suitable time for interruptions with 92% of cases still ongoing. Timing was minimally affected by the type of anaesthesia, surgical facility, surgical service, prone positioning or scheduled case duration. The implication of our results is that for mediated interruptions, waiting at least 13 minutes after the start of surgery is appropriate. Although we used AIMS data, operating room information system data is also suitable.

  3. Sublimator Driven Coldplate Engineering Development Unit Test Results

    NASA Technical Reports Server (NTRS)

    Sheth, Rubik B.; Stephan, Ryan A.; Leimkuehler, Thomas O.

    2010-01-01

    The Sublimator Driven Coldplate (SDC) is a unique piece of thermal control hardware that has several advantages over a traditional thermal control scheme. The principal advantage is the possible elimination of a pumped fluid loop, potentially increasing reliability and reducing complexity while saving both mass and power. Because the SDC requires a consumable feedwater, it can only be used for short mission durations. Additionally, the SDC is ideal for a vehicle with small transport distances and low heat rejection requirements. An SDC Engineering Development Unit was designed and fabricated. Performance tests were performed in a vacuum chamber to quantify and assess the performance of the SDC. The test data was then used to develop correlated thermal math models. Nonetheless, an Integrated Sublimator Driven Coldplate (ISDC) concept is being developed. The ISDC couples a coolant loop with the previously described SDC hardware. This combination allows the SDC to be used as a traditional coldplate during long mission phases and provides for dissimilar system redundancy

  4. 77 FR 26579 - Certain Ground Fault Circuit Interrupters and Products Containing Same; Notice of Final...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-04

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-739] Certain Ground Fault Circuit... importation of certain ground fault circuit interrupters and products containing the same by reason of... entry of ground fault circuit interrupters and products containing the same that infringe one or more of...

  5. 14 CFR 29.1433 - Vacuum systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Equipment Miscellaneous Equipment § 29.1433 Vacuum systems. (a... the discharge lines from the vacuum air pump when the delivery temperature of the air becomes unsafe. (b) Each vacuum air system line and fitting on the discharge side of the pump that might contain...

  6. Vacuum Technology Considerations For Mass Metrology

    PubMed Central

    Abbott, Patrick J.; Jabour, Zeina J.

    2011-01-01

    Vacuum weighing of mass artifacts eliminates the necessity of air buoyancy correction and its contribution to the measurement uncertainty. Vacuum weighing is also an important process in the experiments currently underway for the redefinition of the SI mass unit, the kilogram. Creating the optimum vacuum environment for mass metrology requires careful design and selection of construction materials, plumbing components, pumping, and pressure gauging technologies. We review the vacuum technology1 required for mass metrology and suggest procedures and hardware for successful and reproducible operation. PMID:26989593

  7. CD4+ T-cell-guided structured treatment interruptions of antiretroviral therapy in HIV disease: projecting beyond clinical trials.

    PubMed

    Yazdanpanah, Yazdan; Wolf, Lindsey L; Anglaret, Xavier; Gabillard, Delphine; Walensky, Rochelle P; Moh, Raoul; Danel, Christine; Sloan, Caroline E; Losina, Elena; Freedberg, Kenneth A

    2010-01-01

    International trials have shown that CD4+ T-cell-guided structured treatment interruptions (STI) of antiretroviral therapy (ART) lead to worse outcomes than continuous treatment. We simulated continuous ART and STI strategies with higher CD4+ T-cell interruption/reintroduction thresholds than those assessed in actual trials. Using a model of HIV, we simulated cohorts of African adults with different baseline CD4+ T-cell counts (< or = 200; 201-350; and 351-500 cells/microl). We varied ART initiation criteria (immediate; CD4+ T-cell count < 350 cells/microl or > or = 350 cells/microl with severe HIV-related disease; and CD4+ T-cell count <200 cells/microl or > or = 200 cells/microl with severe HIV-related disease), and ART interruption/reintroduction thresholds (350/250; 500/350; and 700/500 cells/microl). First-line therapy was non-nucleoside reverse transcriptase inhibitor (NNRTI)-based and second-line therapy was protease inhibitor (PI)-based. STI generally reduced life expectancy compared with continuous ART. Life expectancy increased with earlier ART initiation and higher interruption/reintroduction thresholds. STI reduced life expectancy by 48-69 and 11-30 months compared with continuous ART when interruption/reintroduction thresholds were 350/250 and 500/350 cells/microl, depending on ART initiation criteria. When patients interrupted/reintroduced ART at 700/500 cells/microl, life expectancies ranged from 2 months lower to 1 month higher than continuous ART. STI-related life expectancy increased with decreased risk of virological resistance after ART interruptions. STI with NNRTI-based regimens was almost always less effective than continuous treatment, regardless of interruption/reintroduction thresholds. The risks associated with STI decrease only if patients start ART earlier, interrupt/reintroduce treatment at very high CD4+ T-cell thresholds (700/500 cells/microl) and use first-line medications with higher resistance barriers, such as PIs.

  8. Experimental investigation on the initial expansion stage of vacuum arc on cup-shaped TMF contacts

    NASA Astrophysics Data System (ADS)

    Wang, Ting; Xiu, Shixin; Liu, Zixi; Zhang, Yanzhe; Feng, Dingyu

    2018-02-01

    Arc behavior and measures to control it directly affect the properties of vacuum circuit breakers. Nowadays, transverse magnetic field (TMF) contacts are widely used for medium voltages. A magnetic field perpendicular to the current direction between the TMF contacts makes the arc move, transmitting its energy to the whole contact and avoiding excessive local ablation. Previous research on TMF arc behavior concentrated mainly on the arc movement and less on the initial stage (from arc ignition to an unstable arc column). A significant amount of experiment results suggest that there is a short period of arc stagnation after ignition. The duration of this arc stagnation and the arc characteristics during this stage affect the subsequent arc motion and even the breaking property of interrupters. The present study is of the arc characteristics in the initial stage. Experiments were carried out in a demountable vacuum chamber with cup-shaped TMF contacts. Using a high-speed camera, both single-point arc ignition mode and multiple-point arc ignition (MPAI) mode were observed. The experimental data show that the probability of MPAI mode occurring is related to the arc current. The influences of arc-ignition mode, arc current, and contact diameter on the initial expansion process were investigated. In addition, simulations were performed to analyze the multiple arc expansion process mechanically. Based on the experimental phenomena and simulation results, the mechanism of the arc expansion motion was analyzed.

  9. Gas propagation in a liquid helium cooled vacuum tube following a sudden vacuum loss

    NASA Astrophysics Data System (ADS)

    Dhuley, Ram C.

    This dissertation describes the propagation of near atmospheric nitrogen gas that rushes into a liquid helium cooled vacuum tube after the tube suddenly loses vacuum. The loss-of-vacuum scenario resembles accidental venting of atmospheric air to the beam-line of a superconducting radio frequency particle accelerator and is investigated to understand how in the presence of condensation, the in-flowing air will propagate in such geometry. In a series of controlled experiments, room temperature nitrogen gas (a substitute for air) at a variety of mass flow rates was vented to a high vacuum tube immersed in a bath of liquid helium. Pressure probes and thermometers installed on the tube along its length measured respectively the tube pressure and tube wall temperature rise due to gas flooding and condensation. At high mass in-flow rates a gas front propagated down the vacuum tube but with a continuously decreasing speed. Regression analysis of the measured front arrival times indicates that the speed decreases nearly exponentially with the travel length. At low enough mass in-flow rates, no front propagated in the vacuum tube. Instead, the in-flowing gas steadily condensed over a short section of the tube near its entrance and the front appeared to `freeze-out'. An analytical expression is derived for gas front propagation speed in a vacuum tube in the presence of condensation. The analytical model qualitatively explains the front deceleration and flow freeze-out. The model is then simplified and supplemented with condensation heat/mass transfer data to again find the front to decelerate exponentially while going away from the tube entrance. Within the experimental and procedural uncertainty, the exponential decay length-scales obtained from the front arrival time regression and from the simplified model agree.

  10. Developing a vacuum cooking equipment prototype to produce strawberry jam and optimization of vacuum cooking conditions.

    PubMed

    Okut, Dilara; Devseren, Esra; Koç, Mehmet; Ocak, Özgül Özdestan; Karataş, Haluk; Kaymak-Ertekin, Figen

    2018-01-01

    Purpose of this study was to develop prototype cooking equipment that can work at reduced pressure and to evaluate its performance for production of strawberry jam. The effect of vacuum cooking conditions on color soluble solid content, reducing sugars total sugars HMF and sensory properties were investigated. Also, the optimum vacuum cooking conditions for strawberry jam were optimized for Composite Rotatable Design. The optimum cooking temperature and time were determined targeting maximum soluble solid content and sensory attributes (consistency) and minimum Hue value and HMF content. The optimum vacuum cooking conditions determined were 74.4 °C temperature and 19.8 time. The soluble solid content strawberry jam made by vacuum process were similar to those prepared by traditional method. HMF contents of jams produced with vacuum cooking method were well within limit of standards.

  11. Mitigating errors caused by interruptions during medication verification and administration: interventions in a simulated ambulatory chemotherapy setting

    PubMed Central

    Prakash, Varuna; Koczmara, Christine; Savage, Pamela; Trip, Katherine; Stewart, Janice; McCurdie, Tara; Cafazzo, Joseph A; Trbovich, Patricia

    2014-01-01

    Background Nurses are frequently interrupted during medication verification and administration; however, few interventions exist to mitigate resulting errors, and the impact of these interventions on medication safety is poorly understood. Objective The study objectives were to (A) assess the effects of interruptions on medication verification and administration errors, and (B) design and test the effectiveness of targeted interventions at reducing these errors. Methods The study focused on medication verification and administration in an ambulatory chemotherapy setting. A simulation laboratory experiment was conducted to determine interruption-related error rates during specific medication verification and administration tasks. Interventions to reduce these errors were developed through a participatory design process, and their error reduction effectiveness was assessed through a postintervention experiment. Results Significantly more nurses committed medication errors when interrupted than when uninterrupted. With use of interventions when interrupted, significantly fewer nurses made errors in verifying medication volumes contained in syringes (16/18; 89% preintervention error rate vs 11/19; 58% postintervention error rate; p=0.038; Fisher's exact test) and programmed in ambulatory pumps (17/18; 94% preintervention vs 11/19; 58% postintervention; p=0.012). The rate of error commission significantly decreased with use of interventions when interrupted during intravenous push (16/18; 89% preintervention vs 6/19; 32% postintervention; p=0.017) and pump programming (7/18; 39% preintervention vs 1/19; 5% postintervention; p=0.017). No statistically significant differences were observed for other medication verification tasks. Conclusions Interruptions can lead to medication verification and administration errors. Interventions were highly effective at reducing unanticipated errors of commission in medication administration tasks, but showed mixed effectiveness at

  12. 14 CFR 29.1433 - Vacuum systems.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Vacuum systems. 29.1433 Section 29.1433... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Equipment Miscellaneous Equipment § 29.1433 Vacuum systems. (a.... (b) Each vacuum air system line and fitting on the discharge side of the pump that might contain...

  13. Feasibility of sedation and analgesia interruption following cannulation in neonates on extracorporeal membrane oxygenation

    PubMed Central

    Wildschut, E. D.; Hanekamp, M. N.; Vet, N. J.; Houmes, R. J.; Ahsman, M. J.; Mathot, R. A. A.; de Wildt, S. N.

    2010-01-01

    Purpose In most extracorporeal membrane oxygenation (ECMO) centers patients are heavily sedated to prevent accidental decannulation and bleeding complications. In ventilated adults not on ECMO, daily sedation interruption protocols improve short- and long-term outcome. This study aims to evaluate safety and feasibility of sedation interruption following cannulation in neonates on ECMO. Methods Prospective observational study in 20 neonates (0.17–5.8 days of age) admitted for ECMO treatment. Midazolam (n = 20) and morphine (n = 18) infusions were discontinued within 30 min after cannulation. Pain and sedation were regularly assessed using COMFORT-B and visual analog scale (VAS) scores. Midazolam and/or morphine were restarted and titrated according to protocolized treatment algorithms. Results Median (interquartile range, IQR) time without any sedatives was 10.3 h (5.0–24.1 h). Median interruption duration for midazolam was 16.5 h (6.6–29.6 h), and for morphine was 11.2 h (6.7–39.4 h). During this period no accidental extubations, decannulations or bleeding complications occurred. Conclusions This is the first study to show that interruption of sedatives and analgesics following cannulation in neonates on ECMO is safe and feasible. Interruption times are 2–3 times longer than reported for adult ICU patients not on ECMO. Further trials are needed to substantiate these findings and evaluate short- and long-term outcomes. PMID:20508914

  14. Clinical events after interruption of anticoagulation in patients with atrial fibrillation: An analysis from the ENGAGE AF-TIMI 48 trial.

    PubMed

    Cavallari, Ilaria; Ruff, Christian T; Nordio, Francesco; Deenadayalu, Naveen; Shi, Minggao; Lanz, Hans; Rutman, Howard; Mercuri, Michele F; Antman, Elliott M; Braunwald, Eugene; Giugliano, Robert P

    2018-04-15

    Patients with atrial fibrillation (AF) who interrupt anticoagulation are at high risk of thromboembolism and death. Patients enrolled in the ENGAGE AF-TIMI 48 trial (randomized comparison of edoxaban vs. warfarin) who interrupted study anticoagulant for >3 days were identified. Clinical events (ischemic stroke/systemic embolism, major cardiac and cerebrovascular events [MACCE]) were analyzed from day 4 after interruption until day 34 or study drug resumption. During 2.8 years median follow-up, 13,311 (63%) patients interrupted study drug for >3 days. After excluding those who received open-label anticoagulation during the at-risk window, the population for analysis included 9148 patients. The rates of ischemic stroke/systemic embolism and MACCE post interruption were substantially greater than in patients who never interrupted (15.42 vs. 0.26 and 60.82 vs. 0.36 per 100 patient-years, respectively, p adj  < .001). Patients who interrupted study drug for an adverse event (44.1% of the cohort), compared to those who interrupted for other reasons, had an increased risk of MACCE (HR adj 2.75; 95% CI 2.02-3.74, p < .0001), but similar rates of ischemic stroke/systemic embolism. Rates of clinical events after interruption of warfarin and edoxaban were similar. Interruption of study drug was frequent in patients with AF and was associated with a substantial risk of major cardiac and cerebrovascular events over the ensuing 30 days. This risk was particularly high in patients who interrupted as a result of an adverse event; these patients deserve close monitoring and resumption of anticoagulation as soon as it is safe to do so. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Role of working memory and lexical knowledge in perceptual restoration of interrupted speech.

    PubMed

    Nagaraj, Naveen K; Magimairaj, Beula M

    2017-12-01

    The role of working memory (WM) capacity and lexical knowledge in perceptual restoration (PR) of missing speech was investigated using the interrupted speech perception paradigm. Speech identification ability, which indexed PR, was measured using low-context sentences periodically interrupted at 1.5 Hz. PR was measured for silent gated, low-frequency speech noise filled, and low-frequency fine-structure and envelope filled interrupted conditions. WM capacity was measured using verbal and visuospatial span tasks. Lexical knowledge was assessed using both receptive vocabulary and meaning from context tests. Results showed that PR was better for speech noise filled condition than other conditions tested. Both receptive vocabulary and verbal WM capacity explained unique variance in PR for the speech noise filled condition, but were unrelated to performance in the silent gated condition. It was only receptive vocabulary that uniquely predicted PR for fine-structure and envelope filled conditions. These findings suggest that the contribution of lexical knowledge and verbal WM during PR depends crucially on the information content that replaced the silent intervals. When perceptual continuity was partially restored by filler speech noise, both lexical knowledge and verbal WM capacity facilitated PR. Importantly, for fine-structure and envelope filled interrupted conditions, lexical knowledge was crucial for PR.

  16. Working in a Vacuum

    ERIC Educational Resources Information Center

    Rathey, Allen

    2005-01-01

    In this article, the author discusses several myths about vacuum cleaners and offers tips on evaluating and purchasing this essential maintenance tool. These myths are: (1) Amps mean performance; (2) Everyone needs high-efficiency particulate air (HEPA): (3) Picking up a "bowling ball" shows cleaning power; (4) All vacuum bags are the same; (5)…

  17. Plasmacytoid dendritic cell and functional HIV Gag p55-specific T cells before treatment interruption can inform set-point plasma HIV viral load after treatment interruption in chronically suppressed HIV-1(+) patients.

    PubMed

    Papasavvas, Emmanouil; Foulkes, Andrea; Yin, Xiangfan; Joseph, Jocelin; Ross, Brian; Azzoni, Livio; Kostman, Jay R; Mounzer, Karam; Shull, Jane; Montaner, Luis J

    2015-07-01

    The identification of immune correlates of HIV control is important for the design of immunotherapies that could support cure or antiretroviral therapy (ART) intensification-related strategies. ART interruptions may facilitate this task through exposure of an ART partially reconstituted immune system to endogenous virus. We investigated the relationship between set-point plasma HIV viral load (VL) during an ART interruption and innate/adaptive parameters before or after interruption. Dendritic cell (DC), natural killer (NK) cell and HIV Gag p55-specific T-cell functional responses were measured in paired cryopreserved peripheral blood mononuclear cells obtained at the beginning (on ART) and at set-point of an open-ended interruption from 31 ART-suppressed chronically HIV-1(+) patients. Spearman correlation and linear regression modeling were used. Frequencies of plasmacytoid DC (pDC), and HIV Gag p55-specific CD3(+)  CD4(-)  perforin(+)  IFN-γ(+) cells at the beginning of interruption associated negatively with set-point plasma VL. Inclusion of both variables with interaction into a model resulted in the best fit (adjusted R(2)  = 0·6874). Frequencies of pDC or HIV Gag p55-specific CD3(+)  CD4(-)  CSFE(lo)  CD107a(+) cells at set-point associated negatively with set-point plasma VL. The dual contribution of pDC and anti-HIV T-cell responses to viral control, supported by our models, suggests that these variables may serve as immune correlates of viral control and could be integrated in cure or ART-intensification strategies. © 2015 John Wiley & Sons Ltd.

  18. Hybrid high direct current circuit interrupter

    DOEpatents

    Rockot, Joseph H.; Mikesell, Harvey E.; Jha, Kamal N.

    1998-01-01

    A device and a method for interrupting very high direct currents (greater than 100,000 amperes) and simultaneously blocking high voltages (greater than 600 volts). The device utilizes a mechanical switch to carry very high currents continuously with low loss and a silicon controlled rectifier (SCR) to bypass the current around the mechanical switch while its contacts are separating. A commutation circuit, connected in parallel with the SCR, turns off the SCR by utilizing a resonant circuit to divert the SCR current after the switch opens.

  19. Brain activity patterns induced by interrupting the cognitive processes with online advertising.

    PubMed

    Rejer, Izabela; Jankowski, Jarosław

    2017-11-01

    As a result of the increasing role of online advertising and strong competition among advertisers, intrusive techniques are commonly used to attract web users' attention. Moreover, since marketing content is usually delivered to the target audience when they are performing typical online tasks, like searching for information or reading online content, its delivery interrupts the web user's current cognitive process. The question posed by many researchers in the field of online advertising is: how should we measure the influence of interruption of cognitive processes on human behavior and emotional state? Much research has been conducted in this field; however, most of this research has focused on monitoring activity in the simulated environment, or processing declarative responses given by users in prepared questionnaires. In this paper, a more direct real-time approach is taken, and the effect of the interruption on a web user is analyzed directly by studying the activity of his brain. This paper presents the results of an experiment that was conducted to find the brain activity patterns associated with interruptions of the cognitive process by showing internet advertisements during a text-reading task. Three specific aspects were addressed in the experiment: individual patterns, the consistency of these patterns across trials, and the intra-subject correlation of the individual patterns. Two main effects were observed for most subjects: a drop in activity in the frontal and prefrontal cortical areas across all frequency bands, and significant changes in the frontal/prefrontal asymmetry index.

  20. Improving the estimated cost of sustained power interruptions to electricity customers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LaCommare, Kristina Hamachi; Eto, Joseph H.; Dunn, Laurel N.

    Electricity reliability and resiliency have become a topic of heightened interest in recent years in the United States. As utilities, regulators, and policymakers determine how to achieve optimal levels of electricity reliability while considering how best to prepare for future disruptions in power, the related issue of how much it costs when customers lose power remains a largely unanswered question. In 2006, Lawrence Berkeley National Laboratory developed an end-use based framework that estimates the cost of power interruptions in the U.S that has served as a foundational paper using the best available, yet far from perfect, information at that time.more » Since then, an abundance of work has been done to improve the quality and availability of information that now allow us to make a much more robust assessment of the cost of power interruptions to U.S. customers. In this paper, we find that the total U.S. cost of sustained power interruptions is 44 billion dollars per year (2015-) -25% more than the 26 billion dollars per year in 2002- (or 35 billion dollars per year in 2015-) estimated in our 2006 study.« less

  1. Improving the estimated cost of sustained power interruptions to electricity customers

    DOE PAGES

    LaCommare, Kristina Hamachi; Eto, Joseph H.; Dunn, Laurel N.; ...

    2018-04-18

    Electricity reliability and resiliency have become a topic of heightened interest in recent years in the United States. As utilities, regulators, and policymakers determine how to achieve optimal levels of electricity reliability while considering how best to prepare for future disruptions in power, the related issue of how much it costs when customers lose power remains a largely unanswered question. In 2006, Lawrence Berkeley National Laboratory developed an end-use based framework that estimates the cost of power interruptions in the U.S that has served as a foundational paper using the best available, yet far from perfect, information at that time.more » Since then, an abundance of work has been done to improve the quality and availability of information that now allow us to make a much more robust assessment of the cost of power interruptions to U.S. customers. In this paper, we find that the total U.S. cost of sustained power interruptions is 44 billion dollars per year (2015-) -25% more than the 26 billion dollars per year in 2002- (or 35 billion dollars per year in 2015-) estimated in our 2006 study.« less

  2. Nonperturbative vacuum polarization effects in two-dimensional supercritical Dirac-Coulomb system I. Vacuum charge density

    NASA Astrophysics Data System (ADS)

    Davydov, A.; Sveshnikov, K.; Voronina, Yu.

    2018-01-01

    Based on the original combination of analytical methods, computer algebra tools and numerical calculations, proposed recently in Refs. 1-3, the nonperturbative vacuum polarization effects in the 2+1D supercritical Dirac-Coulomb system with Z > Zcr,1 are explored. Both the vacuum charge density ρV P(r→) and vacuum energy ℰV P are considered. The main result of the work is that in the overcritical region ℰV P turns out to be a rapidly decreasing function ˜-ηeffZ3/R with ηeff > 0 and R being the size of the external Coulomb source. Due to a lot of details of calculation the whole work is divided into two parts I and II. In the present part I, we consider the evaluation and behavior of the vacuum density ρV P, which further is used in part II for evaluation of the vacuum energy, with emphasis on the renormalization, convergence of the partial expansion for ρV P and behavior of the integral induced charge QV P in the overcritical region.

  3. [Deliberate interruptions and changes of dose of inhaled corticosteroids by asthma patients: "a community pharmacy study"].

    PubMed

    Laforest, L; Van Ganse, É; Devouassoux, G; Chatté, G; Tamberou, C; Belhassen, M; Chamba, G

    2015-01-01

    Adherence to inhaled corticosteroids (ICS) remains a major issue for asthma management, even among patients receiving a regular prescription from their doctor. The frequency of deliberate interruption of ICS, and of spontaneous changes of dose, were studied in a population of asthma patients recruited in community pharmacies. Asthma patients (aged 18-50) recruited in community pharmacies reported in self-administered questionnaires their spontaneous interruptions and changes of doses of ICS during the past 3 months. The characteristics of patients who interrupted their therapy or who modified the dose were compared with other patients. The studied population included 252 patients (mean age 35 year-old, females: 59%), of whom 62% had inadequately controlled asthma. Among these patients, 25% had interrupted ICS therapy during the past 3 months, while 21% spontaneously changed the dose. The most reported reason for interrupting ICS was the cessation of symptoms (50%). In multivariate analysis, interrupting ICS was mainly associated with inadequate asthma control (OR=3.1, 95% CI 1.5-6.4), while the strongest association with changing ICS doses was the patients' perception of asthma as a concern in their lives (OR=3.2, 95% CI 1.2-8.4). These results underline a poor understanding of the purpose of ICS therapy by patients. They also highlight the need of therapeutic education to improve the management of the disease. Copyright © 2014 SPLF. Published by Elsevier Masson SAS. All rights reserved.

  4. Calm to chaos: Engaging undergraduate nursing students with the complex nature of interruptions during medication administration.

    PubMed

    Hayes, Carolyn; Jackson, Debra; Davidson, Patricia M; Daly, John; Power, Tamara

    2017-12-01

    To describe undergraduate student nurse responses to a simulated role-play experience focussing on managing interruptions during medication administration. Improving patient safety requires that we find creative and innovative methods of teaching medication administration to undergraduate nurses in real-world conditions. Nurses are responsible for the majority of medication administrations in health care. Incidents and errors associated with medications are a significant patient safety issue and often occur as a result of interruptions. Undergraduate nursing students are generally taught medication administration skills in a calm and uninterrupted simulated environment. However, in the clinical environment medication administration is challenged by multiple interruptions. A qualitative study using convenience sampling was used to examine student perceptions of a simulated role-play experience. Data were collected from 451 of a possible 528 student written reflective responses and subject to thematic analysis. Students reported an increased understanding of the impacts of interruptions while administering medications and an improved awareness of how to manage disruptions. This study reports on one of three emergent themes: "Calm to chaos: engaging with the complex nature of clinical practice." Interrupting medication administration in realistic and safe settings facilitates awareness, allows for students to begin to develop management strategies in relation to interruption and increases their confidence. Students were given the opportunity to consolidate and integrate prior and new knowledge and skills through this role-play simulation. © 2017 John Wiley & Sons Ltd.

  5. Nonperturbative vacuum polarization effects in two-dimensional supercritical Dirac-Coulomb system II. Vacuum energy

    NASA Astrophysics Data System (ADS)

    Davydov, A.; Sveshnikov, K.; Voronina, Yu.

    2018-01-01

    Nonperturbative vacuum polarization effects are explored for a supercritical Dirac-Coulomb system with Z > Zcr,1 in 2+1D, based on the original combination of analytical methods, computer algebra and numerical calculations, proposed recently in Refs. 1-3. Both the vacuum charge density ρV P(r→) and vacuum energy ℰV P are considered. Due to a lot of details of calculation the whole work is divided into two parts I and II. Taking account of results, obtained in the part I4 for ρV P, in the present part II, the evaluation of the vacuum energy ℰV P is investigated with emphasis on the renormalization and convergence of the partial expansion for ℰV P. It is shown that the renormalization via fermionic loop turns out to be the universal tool, which removes the divergence of the theory both in the purely perturbative and essentially nonperturbative regimes of the vacuum polarization. The main result of calculation is that for a wide range of the system parameters in the overcritical region ℰV P turns out to be a rapidly decreasing function ˜-ηeffZ3/R with ηeff > 0 and R being the size of the external Coulomb source. To the end the similarity in calculations of ℰV P in 2+1 and 3+1D is discussed, and qualitative arguments are presented in favor of the possibility for complete screening of the classical electrostatic energy of the Coulomb source by the vacuum polarization effects for Z ≫ Zcr,1 in 3+1D.

  6. Quantum vacuum noise in physics and cosmology.

    PubMed

    Davies, P. C. W.

    2001-09-01

    The concept of the vacuum in quantum field theory is a subtle one. Vacuum states have a rich and complex set of properties that produce distinctive, though usually exceedingly small, physical effects. Quantum vacuum noise is familiar in optical and electronic devices, but in this paper I wish to consider extending the discussion to systems in which gravitation, or large accelerations, are important. This leads to the prediction of vacuum friction: The quantum vacuum can act in a manner reminiscent of a viscous fluid. One result is that rapidly changing gravitational fields can create particles from the vacuum, and in turn the backreaction on the gravitational dynamics operates like a damping force. I consider such effects in early universe cosmology and the theory of quantum black holes, including the possibility that the large-scale structure of the universe might be produced by quantum vacuum noise in an early inflationary phase. I also discuss the curious phenomenon that an observer who accelerates through a quantum vacuum perceives a bath of thermal radiation closely analogous to Hawking radiation from black holes, even though an inertial observer registers no particles. The effects predicted raise very deep and unresolved issues about the nature of quantum particles, the role of the observer, and the relationship between the quantum vacuum and the concepts of information and entropy. (c) 2001 American Institute of Physics.

  7. Running vacuum cosmological models: linear scalar perturbations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perico, E.L.D.; Tamayo, D.A., E-mail: elduartep@usp.br, E-mail: tamayo@if.usp.br

    In cosmology, phenomenologically motivated expressions for running vacuum are commonly parameterized as linear functions typically denoted by Λ( H {sup 2}) or Λ( R ). Such models assume an equation of state for the vacuum given by P-bar {sub Λ} = - ρ-bar {sub Λ}, relating its background pressure P-bar {sub Λ} with its mean energy density ρ-bar {sub Λ} ≡ Λ/8π G . This equation of state suggests that the vacuum dynamics is due to an interaction with the matter content of the universe. Most of the approaches studying the observational impact of these models only consider the interactionmore » between the vacuum and the transient dominant matter component of the universe. We extend such models by assuming that the running vacuum is the sum of independent contributions, namely ρ-bar {sub Λ} = Σ {sub i} ρ-bar {sub Λ} {sub i} . Each Λ i vacuum component is associated and interacting with one of the i matter components in both the background and perturbation levels. We derive the evolution equations for the linear scalar vacuum and matter perturbations in those two scenarios, and identify the running vacuum imprints on the cosmic microwave background anisotropies as well as on the matter power spectrum. In the Λ( H {sup 2}) scenario the vacuum is coupled with every matter component, whereas the Λ( R ) description only leads to a coupling between vacuum and non-relativistic matter, producing different effects on the matter power spectrum.« less

  8. 78 FR 65904 - Permanent Discontinuance or Interruption in Manufacturing of Certain Drug or Biological Products

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-04

    ... in the manufacture of the drug or an interruption in the manufacturing of the drug that is likely to... Manufacturing of Certain Drug or Biological Products AGENCY: Food and Drug Administration, HHS. ACTION: Proposed... permanent discontinuance or an interruption in manufacturing of the product that is likely to lead to a...

  9. Pardon Me, Can I Talk Now?: A Look at the Roles of Interruptions in Conversation.

    ERIC Educational Resources Information Center

    Ringer, R. Jeffrey

    Several theories exist to explain the differences in the interruptive behavior of men and women. Early research suggested that men interrupt more than women, and this finding was attributed to the dominant/submissive relationship traditional in relationships among men and women. Later studies, however, found that either there were no significant…

  10. Metal vapor arc switch electromagnetic accelerator technology

    NASA Technical Reports Server (NTRS)

    Mongeau, P. P.

    1984-01-01

    A multielectrode device housed in an insulator vacuum vessel, the metal vapor vacuum switch has high power capability and can hold off voltages up to the 100 kilovolt level. Such switches can be electronically triggered and can interrupt or commutate at a zero current crossing. The physics of arc initiation, arc conduction, and interruption are examined, including material considerations; inefficiencies; arc modes; magnetic field effects; passive and forced extinction; and voltage recovery. Heating, electrode lifetime, device configuration, and external circuit configuration are discussed. The metal vapor vacuum switch is compared with SCRs, GTOs, spark gaps, ignitrons, and mechanical breakers.

  11. Unique Conformation in a Natural Interruption Sequence of Type XIX Collagen Revealed by Its High-Resolution Crystal Structure.

    PubMed

    Xu, Tingting; Zhou, Cong-Zhao; Xiao, Jianxi; Liu, Jinsong

    2018-02-20

    Naturally occurring interruptions in nonfibrillar collagen play key roles in molecular flexibility, collagen degradation, and ligand binding. The structural feature of the interruption sequences and the molecular basis for their functions have not been well studied. Here, we focused on a G5G type natural interruption sequence G-POALO-G from human type XIX collagen, a homotrimer collagen, as this sequence possesses distinct properties compared with those of a pathological similar Gly mutation sequence in collagen mimic peptides. We determined the crystal structures of the host-guest peptide (GPO) 3 -GPOALO-(GPO) 4 to 1.03 Å resolution in two crystal forms. In these structures, the interruption zone brings localized disruptions to the triple helix and introduces a light 6-8° bend with the same directional preference to the whole molecule, which may correspond structurally to the first physiological kink site in type XIX collagen. Furthermore, at the G5G interruption site, the presence of Ala and Leu residues, both with free N-H groups, allows the formation of more direct and water-mediated interchain hydrogen bonds than in the related Gly → Ala structure. These could partly explain the difference in thermal stability between the different interruptions. In addition, our structures provide a detailed view of the dynamic property of such an interrupted zone with respect to hydrogen bonding topology, torsion angles, and helical parameters. Our results, for the first time, also identified the binding of zinc to the end of the triple helix. These findings will shed light on how the interruption sequence influences the conformation of the collagen molecule and provide a structural basis for further functional studies.

  12. 21 CFR 884.4340 - Fetal vacuum extractor.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... means of a suction cup attached to the scalp and is powered by an external vacuum source. This generic type of device may include the cup, hosing, vacuum source, and vacuum control. (b) Classification...

  13. 21 CFR 884.4340 - Fetal vacuum extractor.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... means of a suction cup attached to the scalp and is powered by an external vacuum source. This generic type of device may include the cup, hosing, vacuum source, and vacuum control. (b) Classification...

  14. Increased short-term risk of thrombo-embolism or death after interruption of warfarin treatment in patients with atrial fibrillation.

    PubMed

    Raunsø, Jakob; Selmer, Christian; Olesen, Jonas Bjerring; Charlot, Mette Gitz; Olsen, Anne-Marie S; Bretler, Ditte-Marie; Nielsen, Jørn Dalsgaard; Dominguez, Helena; Gadsbøll, Niels; Køber, Lars; Gislason, Gunnar H; Torp-Pedersen, Christian; Hansen, Morten Lock

    2012-08-01

    It is presently unknown whether patients with atrial fibrillation (AF) are at increased risk of thrombo-embolic adverse events after interruption of warfarin treatment. The purpose of this study was to assess the risk and timing of thrombo-embolism after warfarin treatment interruption. A retrospective, nationwide cohort study of all patients in Denmark treated with warfarin after a first hospitalization with AF in the period 1997-2008. Incidence rate ratios (IRRs) of thrombo-embolic events and all-cause mortality were calculated using the Poisson regression analyses. In total, 48 989 AF patients receiving warfarin treatment were included. Of these, 35 396 patients had at least one episode of warfarin treatment interruption. In all, 8255 deaths or thrombo-embolic events occurred during treatment interruption showing an initial clustering of events with 2717, 835, 500, and 427 events occurring during 0-90, 91-180, 181-270, and 271-360 days after treatment interruption, respectively. Correspondingly, the crude incidence rates were 31.6, 17.7, 12.3, and 11.4 events per 100 patient-years. In a multivariable analysis, the first 90-day interval of treatment interruption was associated with a markedly higher risk of death or thrombo-embolism (IRR 2.5; 95% confidence interval 2.3-2.8) vs. the interval of 271-360 days. In patients with AF, an interruption of warfarin treatment is associated with a significantly increased short-term risk of death or thrombo-embolic events within the first 90 days of treatment interruption.

  15. Absorption spectrum of a two-level atom in a bad cavity with injected squeezed vacuum

    NASA Astrophysics Data System (ADS)

    Zhou, Peng; Swain, S.

    1996-02-01

    We study the absorption spectrum of a coherently driven two-level atom interacting with a resonant cavity mode which is coupled to a broadband squeezed vacuum through its input-output mirror in the bad cavity limit. We study the modification of the two-photon correlation strength of the injected squeezed vacuum inside the cavity, and show that the equations describing probe absorption in the cavity environment are formally identical to these in free space, but with modified parameters describing the squeezed vacuum. The two photon correlations induced by the squeezed vacuum are always weaker than in free space. We pay particular attention to the spectral behaviour at line centre in the region of intermediate trength driving intensities, where anomalous spectral features such as hole-burning and dispersive profiles are displayed. These unusual spectral features are very sensitive to the squeezing phase and the Rabi frequency of the driving field. We also derive the threshold value of the Rabi frequency which gives rise to the transparency of the probe beam at the driving frequency. When the Rabi frequency is less than the threshold value, the probe beam is absorbed, whilst the probe beam is amplified (without population inversion under certain conditions) when the Rabi frequency is larger than this threshold. The anomalous spectral features all take place in the vicinity of the critical point dividing the different dynamical regimes, probe absorption and amplification, of the atomic radiation. The physical origin of the strong amplification without population inversion, and the feasibility of observing it, are discussed.

  16. CGG repeat length and AGG interruptions as indicators of fragile X-associated diminished ovarian reserve.

    PubMed

    Lekovich, Jovana; Man, Limor; Xu, Kangpu; Canon, Chelsea; Lilienthal, Debra; Stewart, Joshua D; Pereira, Nigel; Rosenwaks, Zev; Gerhardt, Jeannine

    2017-12-21

    PurposeFragile X premutation (PM) carriers may experience difficulties conceiving a child probably due to fragile X-associated diminished ovarian reserve (FXDOR). We investigated which subgroups of carriers with a PM are at higher risk of FXDOR, and whether the number of AGG interruptions within the repeat sequence further ameliorates the risk.MethodsWe compared markers of ovarian reserve, including anti-Müllerian hormone, antral follicle count, and number of oocytes retrieved between different subgroups of patients with a PM.ResultsWe found that carriers with midrange repeats size (70-90 CGG) demonstrate significantly lower ovarian reserve. Additionally, the number of AGG interruptions directly correlated with parameters of ovarian reserve. Patients with longer uninterrupted CGG repeats post-AGG interruptions had the lowest ovarian reserve.ConclusionThis study connects AGG interruptions and certain CGG repeat length to reduced ovarian reserve in carriers with a PM. A possible explanation for our findings is the proposed gonadotoxicity of the FMR1 transcripts. Reduction of AGG interruptions could increase the likelihood that secondary RNA structures in the FMR1 messenger RNA are formed, which could cause cell dysfunction within the ovaries. These findings may provide women with guidance regarding their fertility potential and accordingly assist with their family planning.GENETICS in MEDICINE advance online publication, 21 December 2017; doi:10.1038/gim.2017.220.

  17. Cold cathode vacuum gauging system

    DOEpatents

    Denny, Edward C.

    2004-03-09

    A vacuum gauging system of the cold cathode type is provided for measuring the pressure of a plurality of separate vacuum systems, such as in a gas centrifuge cascade. Each casing is fitted with a gauge tube assembly which communicates with the vacuum system in the centrifuge casing. Each gauge tube contains an anode which may be in the form of a slender rod or wire hoop and a cathode which may be formed by the wall of the gauge tube. The tube is provided with an insulated high voltage connector to the anode which has a terminal for external connection outside the vacuum casing. The tube extends from the casing so that a portable magnet assembly may be inserted about the tube to provide a magnetic field in the area between the anode and cathode necessary for pressure measurements in a cold cathode-type vacuum gauge arrangement. The portable magnetic assembly is provided with a connector which engages the external high voltage terminal for providing power to the anode within in the gauge tube. Measurement is made in the same manner as the prior cold cathode gauges in that the current through the anode to the cathode is measured as an indication of the pressure. By providing the portable magnetic assembly, a considerable savings in cost, installation, and maintenance of vacuum gauges for pressure measurement in a gas centrifuge cascade is realizable.

  18. Measurement of partial pressures in vacuum technology and vacuum physics

    NASA Technical Reports Server (NTRS)

    Huber, W. K.

    1986-01-01

    It is pointed out that the measurement of gaseous pressures of less than 0.0001 torr is based on the ionization of gas atoms and molecules due to collisions with electrons. The particle density is determined in place of the pressure. The ionization cross sections for molecules of various gases are discussed. It is found that the true pressure in a vacuum system cannot be determined with certainty if it is unknown which gas is present. Effects of partial pressure determination on the condition of the vacuum system are discussed together with ion sources, systems of separation, and ion detection.

  19. VACUUM TRAP AND VALVE COMBINATION

    DOEpatents

    Milleron, N.; Levenson, L.

    1963-02-19

    This patent relates to a vacuum trap and valve combination suitable for use in large ultra-high vacuum systems. The vacuum trap is a chamber having an inlet and outlet opening which may be made to communicate with a chamber to be evacuated and a diffusion pump, respectively. A valve is designed to hermeticaliy seal with inlet opening and, when opened, block the line-of- sight'' between the inlet and outlet openings, while allowing a large flow path between the opened vaive and the side walls of the trap. The interior of the trap and the side of the valve facing the inlet opening are covered with an impurity absorbent, such as Zeolite or activated aluminum. Besides the advantage of combining two components of a vacuum system into one, the present invention removes the need for a baffle between the pump and the chamber to be evacuated. In one use of a specific embodiment of this invention, the transmission probability was 45 and the partial pressure of the pump fluid vapor in the vacuum chamber was at least 100 times lower than its vapor pressure. (AEC)

  20. Hybrid high direct current circuit interrupter

    DOEpatents

    Rockot, J.H.; Mikesell, H.E.; Jha, K.N.

    1998-08-11

    A device and a method are disclosed for interrupting very high direct currents (greater than 100,000 amperes) and simultaneously blocking high voltages (greater than 600 volts). The device utilizes a mechanical switch to carry very high currents continuously with low loss and a silicon controlled rectifier (SCR) to bypass the current around the mechanical switch while its contacts are separating. A commutation circuit, connected in parallel with the SCR, turns off the SCR by utilizing a resonant circuit to divert the SCR current after the switch opens. 7 figs.

  1. Risk factors for interruption to soft contact lens wear in children and young adults.

    PubMed

    Wagner, Heidi; Chalmers, Robin L; Mitchell, G Lynn; Jansen, Meredith E; Kinoshita, Beth T; Lam, Dawn Y; McMahon, Timothy T; Richdale, Kathryn; Sorbara, Luigina

    2011-08-01

    The purpose of this study was to describe age and other risk factors for ocular events that interrupt soft contact lens (SCL) wear in youth. A retrospective chart review of SCL wearers aged 8 to 33 years at the first observed visit was conducted at six academic eye care centers in North America. Data were extracted from all visits during the observation period (>3 years). Clinical records that documented conditions resulting in an interruption of SCL wear "events" were scanned, masked for age and SCL parameters, and then adjudicated to consensus diagnosis. Generalized estimating equations were used to examine the effect of selected covariates, including age, on the risk of an event. Chart review of 3549 SCL wearers yielded 522 events among 426 wearers (12%). The risk of an event increased from ages 8 to 18 years, showed modest increases between ages 19 and 25 years, and then began to decline after age 25 years. New lens wearers (<1 year) were less likely to experience events (p = 0.001). Lens replacement schedule and material were also predictive of interruptions to SCL wear with the lowest risk in daily replacement and hydrogel lens wearers (both p < 0.0001). These results suggest that the risk of events that interrupt SCL wear peaks in late adolescence and early adulthood and reflects risk factors identified in prospective contact lens studies. Relative to older teens and young adults, patients younger than 14 years presented with significantly fewer events resulting in interrupted lens wear.

  2. Vacuum enhanced cutaneous biopsy instrument

    DOEpatents

    Collins, Joseph

    2000-01-01

    A syringe-like disposable cutaneous biopsy instrument equipped with a tubular blade at its lower end, and designed so that a vacuum is created during use, said vacuum serving to retain undeformed a plug of tissue cut from a patient's skin.

  3. Troubleshooting crude vacuum tower overhead ejector systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lines, J.R.; Frens, L.L.

    1995-03-01

    Routinely surveying tower overhead vacuum systems can improve performance and product quality. These vacuum systems normally provide reliable and consistent operation. However, process conditions, supplied utilities, corrosion, erosion and fouling all have an impact on ejector system performance. Refinery vacuum distillation towers use ejector systems to maintain tower top pressure and remove overhead gases. However, as with virtually all refinery equipment, performance may be affected by a number of variables. These variables may act independently or concurrently. It is important to understand basic operating principles of vacuum systems and how performance is affected by: utilities, corrosion and erosion, fouling, andmore » process conditions. Reputable vacuum-system suppliers have service engineers that will come to a refinery to survey the system and troubleshoot performance or offer suggestions for improvement. A skilled vacuum-system engineer may be needed to diagnose and remedy system problems. The affect of these variables on performance is discussed. A case history is described of a vacuum system on a crude tower in a South American refinery.« less

  4. The impact of intra-operative interruptions on surgeons' perceived workload: an observational study in elective general and orthopedic surgery.

    PubMed

    Weigl, Matthias; Antoniadis, Sophia; Chiapponi, Costanza; Bruns, Christiane; Sevdalis, Nick

    2015-01-01

    Surgeons' intra-operative workload is critical for effective and safe surgical performance. Detrimental conditions in the operating room (OR) environment may add to perceived workload and jeopardize surgical performance and outcomes. This study aims to evaluate the impact of different intra-operative workflow interruptions on surgeons' capacity to manage their workload safely and efficiently. This was an observational study of intra-operative interruptions and self-rated workload in two surgical specialties (general, orthopedic/trauma surgery). Intra-operative interruptions were assessed via expert observation using a well-validated observation tool. Surgeons, nurses, and anesthesiologists assessed their intra-operative workload directly after case completion based on three items of the validated Surgery Task Load Index (mental demand, situational stress, distraction). A total of 56 elective cases (35 open, 21 laparoscopic) with 94 workload ratings were included. Mean intra-operative duration was 1 h 37 min. Intra-operative interruptions were on average observed 9.78 times per hour. People who entered/exited the OR (30.6 %) as well as telephone-/beeper-related disruptions (23.6 %) occurred most often. Equipment and OR environment-related interruptions were associated with highest interference with team functioning particularly in laparoscopic procedures. After identifying task and procedural influences, partial correlational analyses revealed that case-irrelevant communications were negatively associated with surgeons' mental fatigue and situational stress, whereas surgeons' reported distraction was increased by case-irrelevant communication and procedural disruptions. OR nurses' and anesthesiologists' perceived workload was also related to intra-operative interruption events. Our study documents the unique contribution of different interruptions on surgeons' workload; whereas case-irrelevant communications may be beneficial for mental fatigue and stress in routine

  5. Mitigating errors caused by interruptions during medication verification and administration: interventions in a simulated ambulatory chemotherapy setting.

    PubMed

    Prakash, Varuna; Koczmara, Christine; Savage, Pamela; Trip, Katherine; Stewart, Janice; McCurdie, Tara; Cafazzo, Joseph A; Trbovich, Patricia

    2014-11-01

    Nurses are frequently interrupted during medication verification and administration; however, few interventions exist to mitigate resulting errors, and the impact of these interventions on medication safety is poorly understood. The study objectives were to (A) assess the effects of interruptions on medication verification and administration errors, and (B) design and test the effectiveness of targeted interventions at reducing these errors. The study focused on medication verification and administration in an ambulatory chemotherapy setting. A simulation laboratory experiment was conducted to determine interruption-related error rates during specific medication verification and administration tasks. Interventions to reduce these errors were developed through a participatory design process, and their error reduction effectiveness was assessed through a postintervention experiment. Significantly more nurses committed medication errors when interrupted than when uninterrupted. With use of interventions when interrupted, significantly fewer nurses made errors in verifying medication volumes contained in syringes (16/18; 89% preintervention error rate vs 11/19; 58% postintervention error rate; p=0.038; Fisher's exact test) and programmed in ambulatory pumps (17/18; 94% preintervention vs 11/19; 58% postintervention; p=0.012). The rate of error commission significantly decreased with use of interventions when interrupted during intravenous push (16/18; 89% preintervention vs 6/19; 32% postintervention; p=0.017) and pump programming (7/18; 39% preintervention vs 1/19; 5% postintervention; p=0.017). No statistically significant differences were observed for other medication verification tasks. Interruptions can lead to medication verification and administration errors. Interventions were highly effective at reducing unanticipated errors of commission in medication administration tasks, but showed mixed effectiveness at reducing predictable errors of detection in

  6. Ethics of treatment interruption trials in HIV cure research: addressing the conundrum of risk/benefit assessment.

    PubMed

    Henderson, Gail E; Peay, Holly L; Kroon, Eugene; Cadigan, Rosemary Jean; Meagher, Karen; Jupimai, Thidarat; Gilbertson, Adam; Fisher, Jill; Ormsby, Nuchanart Q; Chomchey, Nitiya; Phanuphak, Nittaya; Ananworanich, Jintanat; Rennie, Stuart

    2018-04-01

    Though antiretroviral therapy is the standard of care for people living with HIV, its treatment limitations, burdens, stigma and costs lead to continued interest in HIV cure research. Early-phase cure trials, particularly those that include analytic treatment interruption (ATI), involve uncertain and potentially high risk, with minimal chance of clinical benefit. Some question whether such trials should be offered, given the risk/benefit imbalance, and whether those who choose to participate are acting rationally. We address these questions through a longitudinal decision-making study nested in a Thai acute HIV research cohort.In-depth interviews revealed central themes about decisions to join. Participants felt they possessed an important identity as members of the acute cohort, viewing their bodies as uniquely suited to both testing and potentially benefiting from HIV cure approaches. While acknowledging risks of ATI, most perceived they were given an opportunity to interrupt treatment, to test their own bodies and increase normalcy in a safe, highly monitored circumstance. They were motivated by potential benefits to themselves, the investigators and larger acute cohort, and others with HIV. They believed their own trial experiences and being able to give back to the community were sufficient to offset participation risks.These decisions were driven by the specific circumstances experienced by our participants. Judging risk/benefit ratios without appreciating these lived experiences can lead to false determinations of irrational decision- making. While this does not minimise vital oversight considerations about risk reduction and protection from harm, it argues for inclusion of a more participant-centered approach. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  7. Vapor-barrier Vacuum Isolation System

    NASA Technical Reports Server (NTRS)

    Weinstein, Leonard M. (Inventor); Taminger, Karen M. (Inventor)

    2014-01-01

    A system includes a collimated beam source within a vacuum chamber, a condensable barrier gas, cooling material, a pump, and isolation chambers cooled by the cooling material to condense the barrier gas. Pressure levels of each isolation chamber are substantially greater than in the vacuum chamber. Coaxially-aligned orifices connect a working chamber, the isolation chambers, and the vacuum chamber. The pump evacuates uncondensed barrier gas. The barrier gas blocks entry of atmospheric vapor from the working chamber into the isolation chambers, and undergoes supersonic flow expansion upon entering each isolation chamber. A method includes connecting the isolation chambers to the vacuum chamber, directing vapor to a boundary with the working chamber, and supersonically expanding the vapor as it enters the isolation chambers via the orifices. The vapor condenses in each isolation chamber using the cooling material, and uncondensed vapor is pumped out of the isolation chambers via the pump.

  8. 7 CFR 58.423 - Cheese vacuumizing chamber.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Cheese vacuumizing chamber. 58.423 Section 58.423 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards....423 Cheese vacuumizing chamber. The vacuum chamber shall be satisfactorily constructed and maintained...

  9. 7 CFR 58.423 - Cheese vacuumizing chamber.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Cheese vacuumizing chamber. 58.423 Section 58.423 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards....423 Cheese vacuumizing chamber. The vacuum chamber shall be satisfactorily constructed and maintained...

  10. How much should customers be compensated for interruptions in the drinking water supply?

    PubMed

    Molinos-Senante, María; Sala-Garrido, Ramon

    2017-05-15

    Water supply interruptions directly affect customers, and customers should be compensated accordingly. However, few water regulators have applied compensation policies given the difficulty of estimating the economic value of compensation to customers. In this study, a pioneering approach based on the concept of shadow prices is proposed to determine the compensation that customers should receive for unplanned water interruptions. The Chilean water industry was selected as a case study because there is an ongoing policy discussion between the use of penalties or compensation as an incentive to prevent water supply interruptions. The estimated results indicate that for 2014, the value of compensation ranges between 2.4% and 35.4% of the fixed charge of the water tariff. The methodology and findings of this study are of great relevance to water regulators in defining incentives to prompt water companies to provide reliable water service. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Engineering Matter Interactions Using Squeezed Vacuum

    NASA Astrophysics Data System (ADS)

    Zeytinoǧlu, Sina; Imamoǧlu, Ataç; Huber, Sebastian

    2017-04-01

    Virtually all interactions that are relevant for atomic and condensed matter physics are mediated by quantum fluctuations of the electromagnetic field vacuum. Consequently, controlling the vacuum fluctuations can be used to engineer the strength and the range of interactions. Recent experiments have used this premise to demonstrate novel quantum phases or entangling gates by embedding electric dipoles in photonic cavities or wave guides, which modify the electromagnetic fluctuations. Here, we show theoretically that the enhanced fluctuations in the antisqueezed quadrature of a squeezed vacuum state allow for engineering interactions between electric dipoles without the need for a photonic structure. Thus, the strength and range of the interactions can be engineered in a time-dependent way by changing the spatial profile of the squeezed vacuum in a traveling-wave geometry, which also allows the implementation of chiral dissipative interactions. Using experimentally realized squeezing parameters and including realistic losses, we predict single-atom cooperativities C of up to 10 for the squeezed-vacuum-enhanced interactions.

  12. 34 CFR 650.35 - May fellowship tenure be interrupted?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 34 Education 3 2010-07-01 2010-07-01 false May fellowship tenure be interrupted? 650.35 Section 650.35 Education Regulations of the Offices of the Department of Education (Continued) OFFICE OF POSTSECONDARY EDUCATION, DEPARTMENT OF EDUCATION JACOB K. JAVITS FELLOWSHIP PROGRAM What Conditions Must be Met...

  13. Lightweight Vacuum Jacket for Cryogenic Insulation. Volume 1

    NASA Technical Reports Server (NTRS)

    Barclay, D. L.; Bell, J. E.; Brogren, E. W.; Straayer, J. W.

    1975-01-01

    The feasibility of producing a lightweight vacuum jacket using state-of-the-art technology and materials was examined. Design and analytical studies were made on a full-scale, orbital maneuvering system fuel tank. Preliminary design details were made for the tank assembly, including an optimized vacuum jacket and multilayer insulation system. A half-scale LH2 test model was designed and fabricated, and a force/stiffness proof test was conducted on the vacuum jacket. A vacuum leak rate of .000001 atmosphere ml of helium per second was measured, approximately 1500 hours of vacuum pressure were sustained, and 29 vacuum-pressure cycles were experienced prior to failure.

  14. 7 CFR 305.29 - Vacuum heat treatment schedule.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 5 2010-01-01 2010-01-01 false Vacuum heat treatment schedule. 305.29 Section 305.29... SERVICE, DEPARTMENT OF AGRICULTURE PHYTOSANITARY TREATMENTS Heat Treatments § 305.29 Vacuum heat treatment... vacuum at 8 hours. Maintain the vacuum until the end of the treatment. Gradually increase the temperature...

  15. [The evolution of vacuum extraction in obstetrics].

    PubMed

    Nikolov, A

    2010-01-01

    Vacuum extraction is one of the methods for assisted vaginal delivery. In this article the evolution of vacuum extraction in obstetrics is been discussed. Historical facts and data from the invention up to state-of-the-art vacuum systems in modern obstetrics are presented.

  16. Evaluation of a Prototype Hybrid Vacuum Pump to Provide Vacuum-Assisted Suspension for Above-Knee Prostheses

    PubMed Central

    Major, Matthew J.; Caldwell, Ryan; Fatone, Stefania

    2015-01-01

    Vacuum-assisted suspension (VAS) of prosthetic sockets utilizes a pump to evacuate air from between the prosthetic liner and socket, and are available as mechanical or electric systems. This technical note describes a hybrid pump that benefits from the advantages of mechanical and electric systems, and evaluates a prototype as proof-of-concept. Cyclical bench testing of the hybrid pump mechanical system was performed using a materials testing system to assess the relationship between compression cycles and vacuum pressure. Phase 1 in vivo testing of the hybrid pump was performed by an able-bodied individual using prosthesis simulator boots walking on a treadmill, and phase 2 involved an above-knee prosthesis user walking with the hybrid pump and a commercial electric pump for comparison. Bench testing of 300 compression cycles produced a maximum vacuum of 24 in-Hg. In vivo testing demonstrated that the hybrid pump continued to pull vacuum during walking, and as opposed to the commercial electric pump, did not require reactivation of the electric system during phase 2 testing. The novelty of the hybrid pump is that while the electric system provides rapid, initial vacuum suspension, the mechanical system provides continuous air evacuation while walking to maintain suspension without reactivation of the electric system, thereby allowing battery power to be reserved for monitoring vacuum levels. PMID:27462383

  17. Formation of tungsten oxide nanowires by ion irradiation and vacuum annealing

    NASA Astrophysics Data System (ADS)

    Zheng, Xu-Dong; Ren, Feng; Wu, Heng-Yi; Qin, Wen-Jing; Jiang, Chang-Zhong

    2018-04-01

    Here we reported the fabrication of tungsten oxide (WO3-x ) nanowires by Ar+ ion irradiation of WO3 thin films followed by annealing in vacuum. The nanowire length increases with increasing irradiation fluence and with decreasing ion energy. We propose that the stress-driven diffusion of the irradiation-induced W interstitial atoms is responsible for the formation of the nanowires. Comparing to the pristine film, the fabricated nanowire film shows a 106-fold enhancement in electrical conductivity, resulting from the high-density irradiation-induced vacancies on the oxygen sublattice. The nanostructure exhibits largely enhanced surface-enhanced Raman scattering effect due to the oxygen vacancy. Thus, ion irradiation provides a powerful approach for fabricating and tailoring the surface nanostructures of semiconductors.

  18. Gravitational collapse and the vacuum energy

    NASA Astrophysics Data System (ADS)

    Campos, M.

    2014-03-01

    To explain the accelerated expansion of the universe, models with interacting dark components (dark energy and dark matter) have been considered recently in the literature. Generally, the dark energy component is physically interpreted as the vacuum energy of the all fields that fill the universe. As the other side of the same coin, the influence of the vacuum energy on the gravitational collapse is of great interest. We study such collapse adopting different parameterizations for the evolution of the vacuum energy. We discuss the homogeneous collapsing star fluid, that interacts with a vacuum energy component, using the stiff matter case as example. We conclude this work with a discussion of the Cahill-McVittie mass for the collapsed object.

  19. Gravitational baryogenesis in running vacuum models

    NASA Astrophysics Data System (ADS)

    Oikonomou, V. K.; Pan, Supriya; Nunes, Rafael C.

    2017-08-01

    We study the gravitational baryogenesis mechanism for generating baryon asymmetry in the context of running vacuum models. Regardless of whether these models can produce a viable cosmological evolution, we demonstrate that they produce a nonzero baryon-to-entropy ratio even if the universe is filled with conformal matter. This is a sound difference between the running vacuum gravitational baryogenesis and the Einstein-Hilbert one, since in the latter case, the predicted baryon-to-entropy ratio is zero. We consider two well known and most used running vacuum models and show that the resulting baryon-to-entropy ratio is compatible with the observational data. Moreover, we also show that the mechanism of gravitational baryogenesis may constrain the running vacuum models.

  20. This art of psychoanalysis. Dreaming undreamt dreams and interrupted cries.

    PubMed

    Ogden, Thomas H

    2004-08-01

    It is the art of psychoanalysis in the making, a process inventing itself as it goes, that is the subject of this paper. The author articulates succinctly how he conceives of psychoanalysis, and offers a detailed clinical illustration. He suggests that each analysand unconsciously (and ambivalently) is seeking help in dreaming his 'night terrors' (his undreamt and undreamable dreams) and his 'nightmares' (his dreams that are interrupted when the pain of the emotional experience being dreamt exceeds his capacity for dreaming). Undreamable dreams are understood as manifestations of psychotic and psychically foreclosed aspects of the personality; interrupted dreams are viewed as reflections of neurotic and other non-psychotic parts of the personality. The analyst's task is to generate conditions that may allow the analysand--with the analyst's participation--to dream the patient's previously undreamable and interrupted dreams. A significant part of the analyst's participation in the patient's dreaming takes the form of the analyst's reverie experience. In the course of this conjoint work of dreaming in the analytic setting, the analyst may get to know the analysand sufficiently well for the analyst to be able to say something that is true to what is occurring at an unconscious level in the analytic relationship. The analyst's use of language contributes significantly to the possibility that the patient will be able to make use of what the analyst has said for purposes of dreaming his own experience, thereby dreaming himself more fully into existence.

  1. Recovery of materials from waste printed circuit boards by vacuum pyrolysis and vacuum centrifugal separation.

    PubMed

    Zhou, Yihui; Wu, Wenbiao; Qiu, Keqiang

    2010-11-01

    In this research, a two-step process consisting of vacuum pyrolysis and vacuum centrifugal separation was employed to treat waste printed circuit boards (WPCBs). Firstly, WPCBs were pyrolysed under vacuum condition at 600 °C for 30 min in a lab-scale reactor. Then, the obtained pyrolysis residue was heated under vacuum until the solder was melted, and then the molten solder was separated from the pyrolysis residue by the centrifugal force. The results of vacuum pyrolysis showed that the type-A of WPCBs (the base plates of which was made from cellulose paper reinforced phenolic resin) pyrolysed to form an average of 67.97 wt.% residue, 27.73 wt.% oil, and 4.30 wt.% gas; and pyrolysis of the type-B of WPCBs (the base plates of which was made from glass fiber reinforced epoxy resin) led to an average mass balance of 72.20 wt.% residue, 21.45 wt.% oil, and 6.35 wt.% gas. The results of vacuum centrifugal separation showed that the separation of solder was complete when the pyrolysis residue was heated at 400 °C, and the rotating drum was rotated at 1200 rpm for 10 min. The pyrolysis oil and gas can be used as fuel or chemical feedstock after treatment. The pyrolysis residue after solder separation contained various metals, glass fibers and other inorganic materials, which could be recycled for further processing. The recovered solder can be reused directly and it can also be a good resource of lead and tin for refining. Copyright © 2010 Elsevier Ltd. All rights reserved.

  2. Diffraction-limited storage-ring vacuum technology

    PubMed Central

    Al-Dmour, Eshraq; Ahlback, Jonny; Einfeld, Dieter; Tavares, Pedro Fernandes; Grabski, Marek

    2014-01-01

    Some of the characteristics of recent ultralow-emittance storage-ring designs and possibly future diffraction-limited storage rings are a compact lattice combined with small magnet apertures. Such requirements present a challenge for the design and performance of the vacuum system. The vacuum system should provide the required vacuum pressure for machine operation and be able to handle the heat load from synchrotron radiation. Small magnet apertures result in the conductance of the chamber being low, and lumped pumps are ineffective. One way to provide the required vacuum level is by distributed pumping, which can be realised by the use of a non-evaporable getter (NEG) coating of the chamber walls. It may not be possible to use crotch absorbers to absorb the heat from the synchrotron radiation because an antechamber is difficult to realise with such a compact lattice. To solve this, the chamber walls can work as distributed absorbers if they are made of a material with good thermal conductivity, and distributed cooling is used at the location where the synchrotron radiation hits the wall. The vacuum system of the 3 GeV storage ring of MAX IV is used as an example of possible solutions for vacuum technologies for diffraction-limited storage rings. PMID:25177979

  3. Electric Propulsion Laboratory Vacuum Chamber

    NASA Image and Video Library

    1964-06-21

    Engineer Paul Reader and his colleagues take environmental measurements during testing of a 20-inch diameter ion engine in a vacuum tank at the Electric Propulsion Laboratory (EPL). Researchers at the Lewis Research Center were investigating the use of a permanent-magnet circuit to create the magnetic field required power electron bombardment ion engines. Typical ion engines use a solenoid coil to create this magnetic field. It was thought that the substitution of a permanent magnet would create a comparable magnetic field with a lower weight. Testing of the magnet system in the EPL vacuum tanks revealed no significant operational problems. Reader found the weight of the two systems was similar, but that the thruster’s efficiency increased with the magnet. The EPL contained a series of large vacuum tanks that could be used to simulate conditions in space. Large vacuum pumps reduced the internal air pressure, and a refrigeration system created the cryogenic temperatures found in space.

  4. Pregnancy interruption after second trimester diagnosis of fetal structural anomalies: the New Jersey Fetal Abnormalities Registry.

    PubMed

    Rauch, Eden R; Smulian, John C; DePrince, Kristin; Ananth, Cande V; Marcella, Stephen W

    2005-10-01

    The purpose of this study was to identify factors that predict a decision to interrupt a pregnancy in which there are fetal anomalies in the second trimester. The New Jersey Fetal Abnormalities Registry prospectively recruits and collects information on pregnancies (> or = 15 weeks of gestation) from New Jersey residents in whom a fetal structural anomaly has been suspected by maternal-fetal medicine specialists. Enrolled pregnancies that have major fetal structural abnormalities identified from 15 to 23 weeks of gestation were included. Outcomes were classified as either elective interruption or a natural pregnancy course, which might include a spontaneous fetal death or live birth. Predictors of elective interruption of pregnancy were examined with univariable and multivariable logistic regression analyses. Of the 97 cases, 33% of the women (n = 32) interrupted the pregnancy. Significant variables in the regression model that were associated with a decision to interrupt a pregnancy were earlier identification of fetal anomalies (19.0 +/- 2 weeks of gestation vs 20.5 +/- 2 weeks of gestation; P = .003), the presence of multiple anomalies (78% [25/32] vs 52% [33/63]; P = .01], and a presumption of lethality (56% [18/32] vs 14% [9/65]; P = .0001). These variables corresponded to an odds ratio for pregnancy interruption of 4.2 (95% CI, 1.0, 17.0) for multiple anomalies, 0.8 (95% CI, 0.7, 1.0) for each week of advancing gestational age, and 36.1 (95% CI, 2.9, 450.7) for presumed lethal abnormalities. Early diagnosis, the identification of multiple abnormalities, and an assessment of likely lethality of fetal anomalies are important factors for the optimization of parental autonomy in deciding pregnancy management.

  5. Ejection of Particles from the Free Surface of Shock-Loaded Lead into Vacuum and Gas Medium

    NASA Astrophysics Data System (ADS)

    Ogorodnikov, V. A.; Mikhailov, A. L.; Erunov, S. V.; Antipov, M. V.; Fedorov, A. V.; Syrunin, M. A.; Kulakov, E. V.; Kleshchevnikov, O. A.; Yurtov, I. V.; Utenkov, A. A.; Finyushin, S. A.; Chudakov, E. A.; Kalashnikov, D. A.; Pupkov, A. S.; Chapaev, A. V.; Mishanov, A. V.; Glushikhin, V. V.; Fedoseev, A. V.; Tagirov, R. R.; Kostyukov, S. A.; Tagirova, I. Yu.; Saprykina, E. V.

    2017-12-01

    The presence and behavior of a gas-metal interfacial layer at the free surface of shock-wave driven flying vehicles in gases of various compositions and densities has not been sufficiently studied so far. We present new comparative data on "dusting" from the free surface of lead into vacuum and gas as dependent on the surface roughness, pressure amplitude at the shock-wave front, and phase state of the material. Methods of estimating the mass flux of ejected particles in the presence of a gas medium at the free metal surface are proposed.

  6. A qualitative, exploratory study of nurses' decision-making when interrupted during medication administration within the Paediatric Intensive Care Unit.

    PubMed

    Bower, Rachel A; Coad, Jane E; Manning, Joseph C; Pengelly, Theresa A

    2018-02-01

    In the paediatric intensive care unit (PICU), medication administration is challenging. Empirical studies demonstrate that interruptions occur frequently and that nurses are fundamental in the delivery of medication. However, little is known about nurse's decision making when interrupted during medication administration. Therefore, the objective is to understand decision making when interrupted during medication administration within the PICU. A qualitative study incorporating non-participant observation and audio recorded semi-structured interviews. A convenience sample of ten PICU nurses were interviewed. Each interview schedule was informed by two hours of observation which involved a further 29 PICU nurses. Data was analysed using Framework Analysis. A regional PICU located in a university teaching hospital in the United Kingdom. Analysis resulted in four overarching themes: (1) Guiding the medication process, (2) Concentration, focus and awareness, (3) Influences on interruptions (4) Impact and recovery CONCLUSION: Medication administration within the PICU is an essential but complex activity. Interruptions can impact on focus and concentration which can contribute to patient harm. Decision making by PICU nurses is influenced by interruption awareness, fluctuating levels of concentration, and responding to critically ill patient and families' needs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Vacuum Energy and Inflation: 4. An Inflationary Universe

    ERIC Educational Resources Information Center

    Huggins, Elisha

    2013-01-01

    This is the fourth paper in a series of four. The first paper in the series, "Vacuum Energy and Inflation: 1. A Liter of Vacuum Energy" [EJ1024183] discusses an example of vacuum energy. Vacuum energy is explained as an energy with a negative pressure whose energy density remains constant in an expanding space. Paper 2, "Vacuum…

  8. 21 CFR 884.5070 - Vacuum abortion system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vacuum abortion system. 884.5070 Section 884.5070 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... § 884.5070 Vacuum abortion system. (a) Identification. A vacuum abortion system is a device designed to...

  9. 46 CFR 153.368 - Pressure-vacuum valves.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 5 2014-10-01 2014-10-01 false Pressure-vacuum valves. 153.368 Section 153.368 Shipping... BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Cargo Venting Systems § 153.368 Pressure-vacuum valves. (a) The pressure side of a required pressure-vacuum relief valve...

  10. 46 CFR 153.368 - Pressure-vacuum valves.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 5 2011-10-01 2011-10-01 false Pressure-vacuum valves. 153.368 Section 153.368 Shipping... BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Cargo Venting Systems § 153.368 Pressure-vacuum valves. (a) The pressure side of a required pressure-vacuum relief valve...

  11. 46 CFR 153.368 - Pressure-vacuum valves.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 5 2012-10-01 2012-10-01 false Pressure-vacuum valves. 153.368 Section 153.368 Shipping... BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Cargo Venting Systems § 153.368 Pressure-vacuum valves. (a) The pressure side of a required pressure-vacuum relief valve...

  12. 46 CFR 153.368 - Pressure-vacuum valves.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 5 2013-10-01 2013-10-01 false Pressure-vacuum valves. 153.368 Section 153.368 Shipping... BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Cargo Venting Systems § 153.368 Pressure-vacuum valves. (a) The pressure side of a required pressure-vacuum relief valve...

  13. 46 CFR 153.368 - Pressure-vacuum valves.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Pressure-vacuum valves. 153.368 Section 153.368 Shipping... BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Cargo Venting Systems § 153.368 Pressure-vacuum valves. (a) The pressure side of a required pressure-vacuum relief valve...

  14. 21 CFR 884.5070 - Vacuum abortion system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Vacuum abortion system. 884.5070 Section 884.5070 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... § 884.5070 Vacuum abortion system. (a) Identification. A vacuum abortion system is a device designed to...

  15. 21 CFR 884.5070 - Vacuum abortion system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Vacuum abortion system. 884.5070 Section 884.5070 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... § 884.5070 Vacuum abortion system. (a) Identification. A vacuum abortion system is a device designed to...

  16. 21 CFR 884.5070 - Vacuum abortion system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Vacuum abortion system. 884.5070 Section 884.5070 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... § 884.5070 Vacuum abortion system. (a) Identification. A vacuum abortion system is a device designed to...

  17. 21 CFR 884.5070 - Vacuum abortion system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Vacuum abortion system. 884.5070 Section 884.5070 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... § 884.5070 Vacuum abortion system. (a) Identification. A vacuum abortion system is a device designed to...

  18. The localized quantum vacuum field

    NASA Astrophysics Data System (ADS)

    Dragoman, D.

    2008-03-01

    A model for the localized quantum vacuum is proposed in which the zero-point energy (ZPE) of the quantum electromagnetic field originates in energy- and momentum-conserving transitions of material systems from their ground state to an unstable state with negative energy. These transitions are accompanied by emissions and re-absorptions of real photons, which generate a localized quantum vacuum in the neighborhood of material systems. The model could help resolve the cosmological paradox associated with the ZPE of electromagnetic fields, while reclaiming quantum effects associated with quantum vacuum such as the Casimir effect and the Lamb shift. It also offers a new insight into the Zitterbewegung of material particles.

  19. Direct current hybrid breakers: A design and its realization

    NASA Astrophysics Data System (ADS)

    Atmadji, Ali Mahfudz Surya

    2000-12-01

    voltage of 1kVDC which was rectified having been obtained from a 3-phase lOkV/380V supply. The source was successfully tested to deliver a fault current of 7kA with a time constant of 5ms. The hybrid breaker that was developed could provide protection for 750VDC traction systems. The breaker was equipped with a fault- recognizing circuit based on a current level triggering. An electronic circuit was built for this need and was included in the system. It monitored the system continuously and took action by generating trip signals when a fault was recognized. Interruption was followed by a suitable timing of the fast contact separation in the main breaker and the current-zero creation. An electrodynamically driven mechanism was successfully tested having a dead-time of 300μs to separate the main breaker contacts. Furthermore, a maximum peak current injection of RA at a frequency of 500Hz could be obtained in order to produce an artificial current-zero in the vacuum breaker. A successful current interruption with a prospective value of RA was achieved by the hybrid switching technique. In addition, measures were taken to prevent overvoltages. Experimentally, the concept of a hybrid breaker was compared with the functioning of all mechanical (air breaker) and all electronical (IGCT breaker) versions. Although a single stage interrupting method was verified experimentally, two two-stage interrupting methods were analyzed theoretically.

  20. Vacuum casting of thick polymeric films

    NASA Technical Reports Server (NTRS)

    Cuddihy, E. F.; Moacanin, J.

    1979-01-01

    Bubble formation and layering, which often plague vacuum-evaporated films, are prevented by properly regulating process parameters. Vacuum casting may be applicable to forming thick films of other polymer/solvent solutions.

  1. 14 CFR 25.1433 - Vacuum systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Miscellaneous Equipment § 25.1433 Vacuum systems. There... discharge lines from the vacuum air pump when the delivery temperature of the air becomes unsafe. [Doc. No...

  2. Ceramic vacuum tubes for geothermal well logging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kelly, R.D.

    1977-01-12

    The results of investigations carried out into the availability and suitability of ceramic vacuum tubes for the development of logging tools for geothermal wells are summarized. Design data acquired in the evaluation of ceramic vacuum tubes for the development of a 500/sup 0/C instrumentation amplifier are presented. The general requirements for ceramic vacuum tubes for application to the development of high temperature well logs are discussed. Commercially available tubes are described and future contract activities that specifically relate to ceramic vacuum tubes are detailed. Supplemental data is presented in the appendix. (MHR)

  3. Using Response Interruption and Redirection to Reduce Vocal Stereotypy

    ERIC Educational Resources Information Center

    Sheehey, Patricia H.; Wells, Jenny C.

    2018-01-01

    Response interruption and redirection, commonly referred to as RIR, is an evidence-based intervention that has been demonstrated to quickly reduce moderate to high levels of vocal stereotypy in children with autism spectrum disorder. The RIR intervention is a simple, three-step procedure that can be embedded in classroom instruction with minimal…

  4. Interrupted Aortic Arch Type B in A Patient with Cat Eye Syndrome

    PubMed Central

    Belangero, Sintia Iole Nogueira; Bellucco, Fernanda Teixeira da Silva; Cernach, Mirlene C. S. P.; Hacker, April M.; Emanuel, Beverly S.; Melaragno, Maria Isabel

    2010-01-01

    We report a patient with cat eye syndrome and interrupted aortic arch type B, a typical finding in the 22q11.2 deletion syndrome. Chromosomal analysis and fluorescent in situ hybridization (FISH) showed a supernumerary bisatellited isodicentric marker chromosome derived from chromosome 22. The segment from 22pter to 22q11.2 in the supernumerary chromosome found in our patient does not overlap with the region deleted in patients with the 22q11.2 deletion syndrome. However, the finding of an interrupted aortic arch type B is unusual in CES, although it is a frequent heart defect in the 22q11 deletion syndrome. PMID:19629279

  5. Period of an Interrupted Pendulum

    NASA Astrophysics Data System (ADS)

    Miller, Bradley E.

    2002-11-01

    While demonstrating a classic conservation-of-energy problem to my AP Physics students, I became curious about the periodic motion that ensued for certain initial conditions. The original problem consists of releasing a mass at the end of a string from an initial position horizontal to the plane of a table. The string comes in contact with a peg some distance below the point where the string is attached at the top. One is asked to find what minimum fraction of the string's length should the peg be placed to have the mass complete a circle about the peg. However, when the mass is released from much lower heights, the system undergoes periodic motion that can be thought of as an interrupted pendulum.

  6. Compressed Air/Vacuum Transportation Techniques

    NASA Astrophysics Data System (ADS)

    Guha, Shyamal

    2011-03-01

    General theory of compressed air/vacuum transportation will be presented. In this transportation, a vehicle (such as an automobile or a rail car) is powered either by compressed air or by air at near vacuum pressure. Four version of such transportation is feasible. In all versions, a ``c-shaped'' plastic or ceramic pipe lies buried a few inches under the ground surface. This pipe carries compressed air or air at near vacuum pressure. In type I transportation, a vehicle draws compressed air (or vacuum) from this buried pipe. Using turbine or reciprocating air cylinder, mechanical power is generated from compressed air (or from vacuum). This mechanical power transferred to the wheels of an automobile (or a rail car) drives the vehicle. In type II-IV transportation techniques, a horizontal force is generated inside the plastic (or ceramic) pipe. A set of vertical and horizontal steel bars is used to transmit this force to the automobile on the road (or to a rail car on rail track). The proposed transportation system has following merits: virtually accident free; highly energy efficient; pollution free and it will not contribute to carbon dioxide emission. Some developmental work on this transportation will be needed before it can be used by the traveling public. The entire transportation system could be computer controlled.

  7. Systematic characterization of degas-driven flow for poly(dimethylsiloxane) microfluidic devices

    DOE PAGES

    Liang, David Y.; Tentori, Augusto M.; Dimov, Ivan K.; ...

    2011-01-01

    Degas-driven flow is a novel phenomenon used to propel fluids in poly(dimethylsiloxane) (PDMS)-based microfluidic devices without requiring any external power. This method takes advantage of the inherently high porosity and air solubility of PDMS by removing air molecules from the bulk PDMS before initiating the flow. The dynamics of degas-driven flow are dependent on the channel and device geometries and are highly sensitive to temporal parameters. These dependencies have not been fully characterized, hindering broad use of degas-driven flow as a microfluidic pumping mechanism. Here, we characterize, for the first time, the effect of various parameters on the dynamics ofmore » degas-driven flow, including channel geometry, PDMS thickness, PDMS exposure area, vacuum degassing time, and idle time at atmospheric pressure before loading. We investigate the effect of these parameters on flow velocity as well as channel fill time for the degas-driven flow process. Using our devices, we achieved reproducible flow with a standard deviation of less than 8% for flow velocity, as well as maximum flow rates of up to 3 nL/s and mean flow rates of approximately 1-1.5 nL/s. Parameters such as channel surface area and PDMS chip exposure area were found to have negligible impact on degas-driven flow dynamics, whereas channel cross-sectional area, degas time, PDMS thickness, and idle time were found to have a larger impact. In addition, we develop a physical model that can predict mean flow velocities within 6% of experimental values and can be used as a tool for future design of PDMS-based microfluidic devices that utilize degas-driven flow.« less

  8. Vacuum chamber-free centrifuge with magnetic bearings.

    PubMed

    Park, Cheol Hoon; Kim, Soohyun; Kim, Kyung-Soo

    2013-09-01

    Centrifuges are devices that separate particles of different densities and sizes through the application of a centrifugal force. If a centrifuge could be operated under atmospheric conditions, all vacuum-related components such as the vacuum chamber, vacuum pump, diffusion pump, and sealing could be removed from a conventional centrifuge system. The design and manufacturing procedure for centrifuges could then be greatly simplified to facilitate the production of lightweight centrifuge systems of smaller volume. Furthermore, the maintenance costs incurred owing to wear and tear due to conventional ball bearings would be eliminated. In this study, we describe a novel vacuum chamber-free centrifuge supported by magnetic bearings. We demonstrate the feasibility of the vacuum chamber-free centrifuge by presenting experimental results that verify its high-speed support capability and motoring power capacity.

  9. Vacuum deposition and curing of liquid monomers

    DOEpatents

    Affinito, J.D.

    1993-11-09

    The present invention is the formation of solid polymer layers under vacuum. More specifically, the present invention is the use of standard polymer layer-making equipment that is generally used in an atmospheric environment in a vacuum, and degassing the monomer material prior to injection into the vacuum. Additional layers of polymer or metal may be vacuum deposited onto solid polymer layers. Formation of polymer layers under a vacuum improves material and surface characteristics, and subsequent quality of bonding to additional layers. Further advantages include use of less to no photoinitiator for curing, faster curing, fewer impurities in the polymer electrolyte, as well as improvement in material properties including no trapped gas resulting in greater density, and reduced monomer wetting angle that facilitates spreading of the monomer and provides a smoother finished surface.

  10. Vacuum deposition and curing of liquid monomers

    DOEpatents

    Affinito, J.D.

    1995-03-07

    The present invention is the formation of solid polymer layers under vacuum. More specifically, the present invention is the use of ``standard`` polymer layer-making equipment that is generally used in an atmospheric environment in a vacuum, and degassing the monomer material prior to injection into the vacuum. Additional layers of polymer or metal or oxide may be vacuum deposited onto solid polymer layers. Formation of polymer layers under a vacuum improves material and surface characteristics, and subsequent quality of bonding to additional layers. Further advantages include use of less to no photoinitiator for curing, faster curing, fewer impurities in the polymer electrolyte, as well as improvement in material properties including no trapped gas resulting in greater density, and reduced monomer wetting angle that facilitates spreading of the monomer and provides a smoother finished surface.

  11. Vacuum deposition and curing of liquid monomers

    DOEpatents

    Affinito, John D.

    1993-01-01

    The present invention is the formation of solid polymer layers under vacuum. More specifically, the present invention is the use of "standard" polymer layer-making equipment that is generally used in an atmospheric environment in a vacuum, and degassing the monomer material prior to injection into the vacuum. Additional layers of polymer or metal may be vacuum deposited onto solid polymer layers. Formation of polymer layers under a vacuum improves material and surface characteristics, and subsequent quality of bonding to additional layers. Further advantages include use of less to no photoinitiator for curing, faster curing, fewer impurities in the polymer electrolyte, as well as improvement in material properties including no trapped gas resulting in greater density, and reduced monomer wetting angle that facilitates spreading of the monomer and provides a smoother finished surface.

  12. Vacuum deposition and curing of liquid monomers

    DOEpatents

    Affinito, John D.

    1995-01-01

    The present invention is the formation of solid polymer layers under vacuum. More specifically, the present invention is the use of "standard" polymer layer-making equipment that is generally used in an atmospheric environment in a vacuum, and degassing the monomer material prior to injection into the vacuum. Additional layers of polymer or metal or oxide may be vacuum deposited onto solid polymer layers. Formation of polymer layers under a vacuum improves material and surface characteristics, and subsequent quality of bonding to additional layers. Further advantages include use of less to no photoinitiator for curing, faster curing, fewer impurities in the polymer electrolyte, as well as improvement in material properties including no trapped gas resulting in greater density, and reduced monomer wetting angle that facilitates spreading of the monomer and provides a smoother finished surface.

  13. Cryogenic Insulation System for Soft Vacuum

    NASA Technical Reports Server (NTRS)

    Augustynowicz, S. D.; Fesmire, J. E.

    1999-01-01

    The development of a cryogenic insulation system for operation under soft vacuum is presented in this paper. Conventional insulation materials for cryogenic applications can be divided into three levels of thermal performance, in terms of apparent thermal conductivity [k-value in milliwatt per meter-kelvin (mW/m-K)]. System k-values below 0.1 can be achieved for multilayer insulation operating at a vacuum level below 1 x 10(exp -4) torr. For fiberglass or powder operating below 1 x 10(exp -3) torr, k-values of about 2 are obtained. For foam and other materials at ambient pressure, k-values around 30 are typical. New industry and aerospace applications require a versatile, robust, low-cost thermal insulation with performance in the intermediate range. The target for the new composite insulation system is a k-value below 4.8 mW/m-K (R-30) at a soft vacuum level (from 1 to 10 torr) and boundary temperatures of approximately 77 and 293 kelvin (K). Many combinations of radiation shields, spacers, and composite materials were tested from high vacuum to ambient pressure using cryostat boiloff methods. Significant improvement over conventional systems in the soft vacuum range was demonstrated. The new layered composite insulation system was also shown to provide key benefits for high vacuum applications as well.

  14. Interruptions of activities experienced by nursing professionals in an intensive care unit.

    PubMed

    Prates, Daniele de Oliveira; Silva, Ana Elisa Bauer de Camargo

    2016-09-09

    to analyze the interruptions experienced by nursing professionals while undertaking care activities. an observational study undertaken in two intensive care units. Two nurses observed 33 nursing professionals for three hours. The data were recorded in real time, using a semistructured instrument. after 99 hours of observation of 739 activities, it was identified that 46.82% were interrupted, resulting in 7.85 interruptions per hour. On average, the interruptions compromised 9.42% of the nursing professionals' worktime. The activities geared towards indirect care of the patient suffered the highest number of interruptions (56.65%), with the nursing records being the activity interrupted most. The principal source of the interruptions was external, coming from the health professionals (51%), and the main causes were those related to the patients (34.70%) and to interpersonal communication (26.47%). the activity of nursing suffers a high number of interruptions, mainly caused by the health professionals themselves, indicating that the work environment needs to undergo interventions aiming to reduce the risk of compromising of the professional's performance and to increase the patients' safety. analisar as interrupções experienciadas por profissionais de enfermagem durante realização de atividades assistenciais. estudo observacional realizado em duas unidades de tratamento intensivo. Dois enfermeiros observaram 33 profissionais de enfermagem, por três horas. Os dados foram registrados em tempo real, usando um instrumento semiestruturado. após 99 horas de observação de 739 atividades, foi identificado que 46,82% sofreram interrupções, perfazendo 7,85 interrupções por hora. As interrupções comprometeram, em média, 9,42% do tempo de trabalho dos profissionais de enfermagem. As atividades direcionadas ao cuidado indireto do paciente foram as que sofreram maior número de interrupções (56,65%), sendo o registro de enfermagem a atividade mais interrompida. A

  15. Vacuum-assisted venous return reduces blood usage.

    PubMed

    Banbury, Michael K; White, Jennifer A; Blackstone, Eugene H; Cosgrove, Delos M

    2003-09-01

    To determine whether vacuum-assisted venous return has clinical advantages over conventional gravity drainage apart from allowing the use of smaller cannulas and shorter tubing. A total of 150 valve operations were performed at our institution between February and July 1999 using vacuum-assisted venous return with small venous cannulas connected to short tubing. These were compared with (1) 83 valve operations performed between April 1997 and January 1998 using the initial version of vacuum-assisted venous return, and (2) 124 valve operations performed between January and April of 1997 using conventional gravity drainage. Priming volume, hematocrit value, red blood cell usage, and total blood product usage were compared multivariably. These comparisons were covariate and propensity adjusted for dissimilarities between the groups and confirmed by propensity-matched pairs analysis. Priming volume was 1.4 +/- 0.4 L for small-cannula vacuum-assisted venous return, 1.7 +/- 0.4 L for initial vacuum-assisted venous return, and 2.0 +/- 0.4 L for gravity drainage (P <.0001). Smaller priming resulted in higher hematocrit values both at the beginning of cardiopulmonary bypass (27% +/- 5% compared with 26% +/- 4% and 25% +/- 4%, respectively, P <.0001) and at the end (30% +/- 4% compared with 28% +/- 4% and 27% +/- 4%, respectively, P <.0001). Red cell transfusions were used in 17% of the patients having small-cannula vacuum-assisted venous return, 27% of the initial patients having vacuum-assisted venous return, and 37% of the patients having gravity drainage (P =.001); total blood product usage was 19%, 27%, and 39%, respectively (P =.002). Although ministernotomy also was associated with reduced blood product usage (P <.004), propensity matching on type of sternotomy confirmed the association of vacuum-assisted venous return with lowered blood product usage. Vacuum-assisted venous return results in (1) higher hematocrit values during cardiopulmonary bypass and (2) decreased

  16. Institutional Narcissism, Arrogant Organization Disorder and Interruptions in Organizational Learning

    ERIC Educational Resources Information Center

    Godkin, Lynn; Allcorn, Seth

    2009-01-01

    Purpose: This article aims to present an alternative approach to diagnosing behavioral barriers to organizational learning. Design/methodology/approach: The paper juxtaposes interruptions in organizational learning with characteristics of narcissism and arrogant organization disorder. Psychoanalytically informed theory and DSM-IV criteria are…

  17. Greater Physiological and Behavioral Effects of Interrupted Stress Pattern Compared to Daily Restraint Stress in Rats

    PubMed Central

    Zhang, Wei; Hetzel, Andrea; Shah, Bijal; Atchley, Derek; Blume, Shannon R.; Padival, Mallika A.; Rosenkranz, J. Amiel

    2014-01-01

    Repeated stress can trigger a range of psychiatric disorders, including anxiety. The propensity to develop abnormal behaviors after repeated stress is related to the severity, frequency and number of stressors. However, the pattern of stress exposure may contribute to the impact of stress. In addition, the anxiogenic nature of repeated stress exposure can be moderated by the degree of coping that occurs, and can be reflected in homotypic habituation to the repeated stress. However, expectations are not clear when a pattern of stress presentation is utilized that diminishes habituation. The purpose of these experiments is to test whether interrupted stress exposure decreases homotypic habituation and leads to greater effects on anxiety-like behavior in adult male rats. We found that repeated interrupted restraint stress resulted in less overall homotypic habituation compared to repeated daily restraint stress. This was demonstrated by greater production of fecal boli and greater corticosterone response to restraint. Furthermore, interrupted restraint stress resulted in a lower body weight and greater adrenal gland weight than daily restraint stress, and greater anxiety-like behavior in the elevated plus maze. Control experiments demonstrated that these effects of the interrupted pattern could not be explained by differences in the total number of stress exposures, differences in the total number of days that the stress periods encompased, nor could it be explained as a result of only the stress exposures after an interruption from stress. These experiments demonstrate that the pattern of stress exposure is a significant determinant of the effects of repeated stress, and that interrupted stress exposure that decreases habituation can have larger effects than a greater number of daily stress exposures. Differences in the pattern of stress exposure are therefore an important factor to consider when predicting the severity of the effects of repeated stress on

  18. What Interrupts Suicide Attempts in Men: A Qualitative Study

    PubMed Central

    Player, Michael J.; Proudfoot, Judy; Fogarty, Andrea; Whittle, Erin; Spurrier, Michael; Shand, Fiona; Christensen, Helen; Hadzi-Pavlovic, Dusan; Wilhelm, Kay

    2015-01-01

    Despite higher rates of suicide in men, there is a dearth of research examining the perspectives and experiences of males at risk of suicide, particularly in terms of understanding how interventions can be tailored to men’s specific needs. The current study aimed to examine factors assisting, complicating or inhibiting interventions for men at risk, as well as outlining the roles of family, friends and others in male suicide prevention. Thirty-five male suicide survivors completed one-to-one interviews, and forty-seven family and friends of male suicide survivors participated in eight focus groups. Thematic analysis revealed five major themes: (1) development of suicidal behaviours tends to follow a common path associated with specific types of risk factors (disrupted mood, unhelpful stoic beliefs and values, avoidant coping strategies, stressors), (2) men at risk of suicide tend to systematically misinterpret changes in their behaviour and thinking, (3) understanding mood and behavioural changes in men enables identification of opportunities to interrupt suicide progression, (4) distraction, provision of practical and emotional supports, along with professional intervention may effectively interrupt acute risk of harm, and (5) suicidal ideation may be reduced through provision of practical help to manage crises, and helping men to focus on obligations and their role within families. Findings suggest that interventions for men at risk of suicidal behaviours need to be tailored to specific risk indicators, developmental factors, care needs and individuals’ preferences. To our knowledge this is the first qualitative study to explore the experiences of both suicidal men and their family/friends after a suicide attempt, with the view to improve understanding of the processes which are effective in interrupting suicide and better inform interventions for men at risk. PMID:26090794

  19. Toy Modification Note: Build It Yourself Battery Interrupter. Revised.

    ERIC Educational Resources Information Center

    Vanderheiden, Gregg C.; Brandenburg, S.

    This toy modification note presents illustrated instructions on how to build a battery interrupter that permits on/off control of battery-operated toys without modification of the toys themselves. The device allows for a separate control switch which can be custom designed to fit a handicapped user's needs. Information on the construction and use…

  20. Asymptomatic Interrupted Aortic Arch, Severe Tricuspid Regurgitation, and Bicuspid Aortic Valve in a 76-Year-Old Woman.

    PubMed

    Tajdini, Masih; Sardari, Akram; Forouzannia, Seyed Khalil; Baradaran, Abdolvahab; Hosseini, Seyed Mohammad Reza; Kassaian, Seyed Ebrahim

    2016-10-01

    Interrupted aortic arch is a rare congenital abnormality with a high infancy mortality rate. The principal finding is loss of luminal continuity between the ascending and descending portions of the aorta. Because of the high mortality rate in infancy, interrupted aortic arch is very rare among adults. In this report, we describe the case of a 76-year-old woman with asymptomatic interrupted aortic arch, severe tricuspid regurgitation, and bicuspid aortic valve. To our knowledge, she is the oldest patient ever reported with this possibly unique combination of pathologic conditions. In addition to reporting her case, we review the relevant medical literature.

  1. Purifying Aluminum by Vacuum Distillation

    NASA Technical Reports Server (NTRS)

    Du Fresne, E. R.

    1985-01-01

    Proposed method for purifying aluminum employs one-step vacuum distillation. Raw material for process impure aluminum produced in electrolysis of aluminum ore. Impure metal melted in vacuum. Since aluminum has much higher vapor pressure than other constituents, boils off and condenses on nearby cold surfaces in proportions much greater than those of other constituents.

  2. Microsurgical Performance After Sleep Interruption: A NeuroTouch Simulator Study.

    PubMed

    Micko, Alexander; Knopp, Karoline; Knosp, Engelbert; Wolfsberger, Stefan

    2017-10-01

    In times of the ubiquitous debate about doctors' working hour restrictions, it is still questionable if the physician's performance is impaired by high work load and long shifts. In this study, we evaluated the impact of sleep interruption on neurosurgical performance. Ten medical students and 10 neurosurgical residents were tested on the virtual-reality simulator NeuroTouch by performing an identical microsurgical task, well rested (baseline test), and after sleep interruption at night (stress test). Deviation of total score, timing, and excessive force on tissue were evaluated. In addition, vital parameters and self-assessment were analyzed. After sleep interruption, total performance score increased significantly (45.1 vs. 48.7, baseline vs. stress test, P = 0.048) while timing remained stable (10.1 vs. 10.4 minutes for baseline vs. stress test, P > 0.05) for both students and residents. Excessive force decreased in both groups during the stress test for the nondominant hand (P = 0.05). For the dominant hand, an increase of excessive force was encountered in the group of residents (P = 0.05). In contrast to their results, participants of both groups assessed their performance worse during the stress test. In our study, we found an increase of neurosurgical simulator performance in neurosurgical residents and medical students under simulated night shift conditions. Further, microsurgical dexterity remained unchanged. Based on our results and the data in the available literature, we cannot confirm that working hour restrictions will have a positive effect on neurosurgical performance. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Breakdown-Resistant RF Connectors for Vacuum

    NASA Technical Reports Server (NTRS)

    Caro, Edward R.; Bonazza, Walter J.

    1987-01-01

    Resilient inserts compensate for insulation shrinkage. Coaxial-cable connector for radio-frequency (RF) energy resists electrical breakdown in vacuum. Used on RF equipment in vacuum chambers as well as in spaceborne radar and communication gear.

  4. The effect of interruptions during training on the time to the first trial and race start in Thoroughbred racehorses.

    PubMed

    Bolwell, C F; Rogers, C W; French, N P; Firth, E C

    2013-02-01

    Few studies have investigated the effect of having interruptions during training on future training and racing performance in Thoroughbred racehorses. The aim of this paper was to investigate the effect of having an interruption before the first trial on starting in a trial or a race. A prospective cohort study was used to record the training activity of a cohort of Thoroughbred racehorses, over two racing seasons. Fourteen racehorse trainers recorded information on the distances worked at canter and at fast speeds (<15s/200 m) and provided reasons for horses not training, or for having interruptions (break from training). Trial and racing results were obtained from the New Zealand Thoroughbred Racing online database. A Cox proportional hazards regression model was used to investigate two outcome measures of performance: (1) time to the first trial and (2) time to the first race. The type of interruption that had occurred before the first trial was the main exposure of interest, and was grouped into: no interruption, voluntary (no known condition or disease present) and involuntary interruptions (due to the presence of a condition or disease). A total of 160/200 (80%) horses started in at least one trial and 100/205 (48%) horses started in at least one race during the study period. The median time to starting in a trial or a race differed significantly (p<0.001) with the type of interruption. The hazard of starting in a trial was lower for horses experiencing voluntary and involuntary interruptions (p<0.001) but there was no association with starting in a race, after adjusting for confounding variables. As age at the start of training increased the hazard of starting in a trial decreased. Horses accumulating longer distances at 15s/200 m had a higher hazard of starting in a trial, whilst horses accumulating fewer events at high speed and fewer trials had a reduced hazard of starting in a race. There was significant clustering at the trainer level for both the

  5. Breather cloth for vacuum curing

    NASA Technical Reports Server (NTRS)

    Reed, M. W.

    1979-01-01

    Finely-woven nylon cloth that has been treated with Teflon improves vacuum adhesive bonding of coatings to substrates. Cloth is placed over coating; entire assembly, including substrate, coating, and cloth, is placed in plastic vacuum bag for curing. Cloth allows coating to "breathe" when bag is evacuated. Applications include bonding film coatings to solar concentrators and collectors.

  6. Vacuum Gas Tungsten Arc Welding

    NASA Technical Reports Server (NTRS)

    Weeks, J. L.; Todd, D. T.; Wooten, J. R.

    1997-01-01

    A two-year program investigated vacuum gas tungsten arc welding (VGTAW) as a method to modify or improve the weldability of normally difficult-to-weld materials. After a vacuum chamber and GTAW power supply were modified, several difficult-to-weld materials were studied and key parameters developed. Finally, Incoloy 903 weld overlays were produced without microfissures.

  7. A robust interrupted time series model for analyzing complex health care intervention data.

    PubMed

    Cruz, Maricela; Bender, Miriam; Ombao, Hernando

    2017-12-20

    Current health policy calls for greater use of evidence-based care delivery services to improve patient quality and safety outcomes. Care delivery is complex, with interacting and interdependent components that challenge traditional statistical analytic techniques, in particular, when modeling a time series of outcomes data that might be "interrupted" by a change in a particular method of health care delivery. Interrupted time series (ITS) is a robust quasi-experimental design with the ability to infer the effectiveness of an intervention that accounts for data dependency. Current standardized methods for analyzing ITS data do not model changes in variation and correlation following the intervention. This is a key limitation since it is plausible for data variability and dependency to change because of the intervention. Moreover, present methodology either assumes a prespecified interruption time point with an instantaneous effect or removes data for which the effect of intervention is not fully realized. In this paper, we describe and develop a novel robust interrupted time series (robust-ITS) model that overcomes these omissions and limitations. The robust-ITS model formally performs inference on (1) identifying the change point; (2) differences in preintervention and postintervention correlation; (3) differences in the outcome variance preintervention and postintervention; and (4) differences in the mean preintervention and postintervention. We illustrate the proposed method by analyzing patient satisfaction data from a hospital that implemented and evaluated a new nursing care delivery model as the intervention of interest. The robust-ITS model is implemented in an R Shiny toolbox, which is freely available to the community. Copyright © 2017 John Wiley & Sons, Ltd.

  8. Pituitary stalk interruption syndrome presenting as short stature: a case report.

    PubMed

    Ram, Nanik; Ali, Syed Ahsan; Hussain, Syed Zubair

    2014-12-19

    Pituitary stalk interruption syndrome is a rare congenital abnormality of the pituitary that is responsible for anterior pituitary deficiency. It is characterized by a classic triad of interrupted pituitary stalk, absent or ectopic posterior pituitary, and anterior pituitary hypoplasia or aplasia. Clinical presentation varies according to age. In adults it presents as short stature and anterior pituitary deficiency. Without early diagnosis and treatment, mortality and morbidity in these patients is high. Early diagnosis and treatment of this rare disease can prevent permanent short statue of the patient. We report the first case of pituitary stalk interruption syndrome from Pakistan. A 17-year-old Pakistani young man presented with short stature and underdeveloped secondary sexual characters. His siblings and parents were healthy, with normal height. An examination showed his blood pressure was 90/60 mmHg, and his height, weight, and body mass index were 142 cm, 34.5 kg, and 17.10 kg/m2, respectively. He had no hair growth on his face, axilla, or pubis. His testes were between 1 and 2 mL in size, with a 4 cm-at-stretch micropenis. His lab investigations showed that his thyroid stimulating hormone (TSH) was 8.58 uIU/mL (0.4 to 4.2), his free thyroid hormone level FT4 was 0.46 ng/dL (0.89 to 1.76), his prolactin was 21.1 ng/mL (3.0 to 14.7), and his baseline cortisol was 0.30 ug/dL (4.3 to 22.4). His cortisol level after 60 minutes of cosyntropin injection was 3.5 ug/dL (4.3 to 22.4), his insulin like growth factor IGF-1 was 31.56 ng/mL (247.3 to 481.7), his testosterone level was under 2.5 ng/dL (2 to 800), his follicle stimulating hormone FSH was 0.41 uIU/mL (0.0 to 10.0), and his leutinizing hormone LH was under 0.1 uIU/mL (1.2 to 7.8). His bone age was 10 years according to the Greulich and Pyle method, as shown by X-rays. The results from his pituitary magnetic resonance imaging scan were consistent with pituitary stalk interruption syndrome. We describe a young

  9. An online, energy-resolving beam profile detector for laser-driven proton beams.

    PubMed

    Metzkes, J; Zeil, K; Kraft, S D; Karsch, L; Sobiella, M; Rehwald, M; Obst, L; Schlenvoigt, H-P; Schramm, U

    2016-08-01

    In this paper, a scintillator-based online beam profile detector for the characterization of laser-driven proton beams is presented. Using a pixelated matrix with varying absorber thicknesses, the proton beam is spatially resolved in two dimensions and simultaneously energy-resolved. A thin plastic scintillator placed behind the absorber and read out by a CCD camera is used as the active detector material. The spatial detector resolution reaches down to ∼4 mm and the detector can resolve proton beam profiles for up to 9 proton threshold energies. With these detector design parameters, the spatial characteristics of the proton distribution and its cut-off energy can be analyzed online and on-shot under vacuum conditions. The paper discusses the detector design, its characterization and calibration at a conventional proton source, as well as the first detector application at a laser-driven proton source.

  10. Apparatus For Metal/Inert-Gas Welding In Vacuum

    NASA Technical Reports Server (NTRS)

    Stocks, C. O.

    1994-01-01

    Metal/inert-gas welding-torch assembly operates in vacuum. Plasma generated in interior chamber and focused onto workpiece in vacuum. Pinch rollers feed wire to weld puddle. Controlled flow of plasma reduces dispersal in vacuum, preventing extinction.

  11. Effects of unplanned treatment interruptions on HIV treatment failure - results from TAHOD.

    PubMed

    Jiamsakul, Awachana; Kerr, Stephen J; Ng, Oon Tek; Lee, Man Po; Chaiwarith, Romanee; Yunihastuti, Evy; Van Nguyen, Kinh; Pham, Thuy Thanh; Kiertiburanakul, Sasisopin; Ditangco, Rossana; Saphonn, Vonthanak; Sim, Benedict L H; Merati, Tuti Parwati; Wong, Wingwai; Kantipong, Pacharee; Zhang, Fujie; Choi, Jun Yong; Pujari, Sanjay; Kamarulzaman, Adeeba; Oka, Shinichi; Mustafa, Mahiran; Ratanasuwan, Winai; Petersen, Boondarika; Law, Matthew; Kumarasamy, Nagalingeswaran

    2016-05-01

    Treatment interruptions (TIs) of combination antiretroviral therapy (cART) are known to lead to unfavourable treatment outcomes but do still occur in resource-limited settings. We investigated the effects of TI associated with adverse events (AEs) and non-AE-related reasons, including their durations, on treatment failure after cART resumption in HIV-infected individuals in Asia. Patients initiating cART between 2006 and 2013 were included. TI was defined as stopping cART for >1 day. Treatment failure was defined as confirmed virological, immunological or clinical failure. Time to treatment failure during cART was analysed using Cox regression, not including periods off treatment. Covariables with P < 0.10 in univariable analyses were included in multivariable analyses, where P < 0.05 was considered statistically significant. Of 4549 patients from 13 countries in Asia, 3176 (69.8%) were male and the median age was 34 years. A total of 111 (2.4%) had TIs due to AEs and 135 (3.0%) had TIs for other reasons. Median interruption times were 22 days for AE and 148 days for non-AE TIs. In multivariable analyses, interruptions >30 days were associated with failure (31-180 days HR = 2.66, 95%CI (1.70-4.16); 181-365 days HR = 6.22, 95%CI (3.26-11.86); and >365 days HR = 9.10, 95% CI (4.27-19.38), all P < 0.001, compared to 0-14 days). Reasons for previous TI were not statistically significant (P = 0.158). Duration of interruptions of more than 30 days was the key factor associated with large increases in subsequent risk of treatment failure. If TI is unavoidable, its duration should be minimised to reduce the risk of failure after treatment resumption. © 2016 John Wiley & Sons Ltd.

  12. Effects of unplanned treatment interruptions on HIV treatment failure– results from TAHOD

    PubMed Central

    Jiamsakul, Awachana; Kerr, Stephen J.; Ng, Oon Tek; Lee, Man Po; Chaiwarith, Romanee; Yunihastuti, Evy; Van Nguyen, Kinh; Pham, Thuy Thanh; Kiertiburanakul, Sasisopin; Ditangco, Rossana; Saphonn, Vonthanak; Sim, Benedict L. H.; Merati, Tuti Parwati; Wong, Wingwai; Kantipong, Pacharee; Zhang, Fujie; Choi, Jun Yong; Pujari, Sanjay; Kamarulzaman, Adeeba; Oka, Shinichi; Mustafa, Mahiran; Ratanasuwan, Winai; Petersen, Boondarika; Law, Matthew; Kumarasamy, Nagalingeswaran

    2016-01-01

    Objectives Treatment interruptions (TI) of combination antiretroviral therapy (cART) are known to lead to unfavourable treatment outcomes but do still occur in resource-limited settings. We investigated the effects of TI associated with adverse events (AEs) and non-AE-related reasons, including their durations, on treatment failure after cART resumption in HIV-infected individuals in Asia. Methods Patients initiating cART between 2006-2013 were included. TI was defined as stopping cART for >1 day. Treatment failure was defined as confirmed virological, immunological or clinical failure. Time to treatment failure during cART was analysed using Cox regression, not including periods off treatment. Co-variables with p<0.10 in univariable analyses were included in multivariable analyses, where p<0.05 was considered statistically significant. Results Of 4549 patients from 13 countries in Asia, 3176 (69.8%) were male and the median age was 34 years. A total of 111 (2.4%) had TIs due to AEs and 135 (3.0%) had TIs for other reasons. Median interruption times were 22 days for AE and 148 days for non-AE TIs. In multivariable analyses, interruptions >30 days were associated with failure (31-180 days HR=2.66, 95%CI (1.70-4.16); 181-365 days HR=6.22, 95%CI (3.26-11.86); and >365 days HR=9.10, 95% CI (4.27-19.38), all p<0.001, compared to 0-14 days). Reasons for previous TI were not statistically significant (p=0.158). Conclusions Duration of interruptions of more than 30 days was the key factor associated with large increases in subsequent risk of treatment failure. If TI is unavoidable, its duration should be minimised to reduce the risk of failure after treatment resumption. PMID:26950901

  13. TFTR diagnostic vacuum controller

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Olsen, D.; Persons, R.

    1981-01-01

    The TFTR diagnostic vacuum controller (DVC) provides in conjunction with the Central Instrumentation Control and Data Acquisition System (CICADA), control and monitoring for the pumps, valves and gauges associated with each individual diagnostic vacuum system. There will be approximately 50 systems on TFTR. Two standard versions of the controller (A and B) wil be provided in order to meet the requirements of two diagnostic manifold arrangements. All pump and valve sequencing, as well as protection features, will be implemented by the controller.

  14. Microsatellite Interruptions Stabilize Primate Genomes and Exist as Population-Specific Single Nucleotide Polymorphisms within Individual Human Genomes

    PubMed Central

    Ananda, Guruprasad; Hile, Suzanne E.; Breski, Amanda; Wang, Yanli; Kelkar, Yogeshwar; Makova, Kateryna D.; Eckert, Kristin A.

    2014-01-01

    Interruptions of microsatellite sequences impact genome evolution and can alter disease manifestation. However, human polymorphism levels at interrupted microsatellites (iMSs) are not known at a genome-wide scale, and the pathways for gaining interruptions are poorly understood. Using the 1000 Genomes Phase-1 variant call set, we interrogated mono-, di-, tri-, and tetranucleotide repeats up to 10 units in length. We detected ∼26,000–40,000 iMSs within each of four human population groups (African, European, East Asian, and American). We identified population-specific iMSs within exonic regions, and discovered that known disease-associated iMSs contain alleles present at differing frequencies among the populations. By analyzing longer microsatellites in primate genomes, we demonstrate that single interruptions result in a genome-wide average two- to six-fold reduction in microsatellite mutability, as compared with perfect microsatellites. Centrally located interruptions lowered mutability dramatically, by two to three orders of magnitude. Using a biochemical approach, we tested directly whether the mutability of a specific iMS is lower because of decreased DNA polymerase strand slippage errors. Modeling the adenomatous polyposis coli tumor suppressor gene sequence, we observed that a single base substitution interruption reduced strand slippage error rates five- to 50-fold, relative to a perfect repeat, during synthesis by DNA polymerases α, β, or η. Computationally, we demonstrate that iMSs arise primarily by base substitution mutations within individual human genomes. Our biochemical survey of human DNA polymerase α, β, δ, κ, and η error rates within certain microsatellites suggests that interruptions are created most frequently by low fidelity polymerases. Our combined computational and biochemical results demonstrate that iMSs are abundant in human genomes and are sources of population-specific genetic variation that may affect genome stability. The

  15. A Rapid Capillary-Pressure Driven Micro-Channel to Demonstrate Newtonian Fluid Behavior of Zebrafish Blood at High Shear Rates.

    PubMed

    Lee, Juhyun; Chou, Tzu-Chieh; Kang, Dongyang; Kang, Hanul; Chen, Junjie; Baek, Kyung In; Wang, Wei; Ding, Yichen; Carlo, Dino Di; Tai, Yu-Chong; Hsiai, Tzung K

    2017-05-16

    Blood viscosity provides the rheological basis to elucidate shear stress underlying developmental cardiac mechanics and physiology. Zebrafish is a high throughput model for developmental biology, forward-genetics, and drug discovery. The micro-scale posed an experimental challenge to measure blood viscosity. To address this challenge, a microfluidic viscometer driven by surface tension was developed to reduce the sample volume required (3μL) for rapid (<2 min) and continuous viscosity measurement. By fitting the power-law fluid model to the travel distance of blood through the micro-channel as a function of time and channel configuration, the experimentally acquired blood viscosity was compared with a vacuum-driven capillary viscometer at high shear rates (>500 s -1 ), at which the power law exponent (n) of zebrafish blood was nearly 1 behaving as a Newtonian fluid. The measured values of whole blood from the micro-channel (4.17cP) and the vacuum method (4.22cP) at 500 s -1 were closely correlated at 27 °C. A calibration curve was established for viscosity as a function of hematocrits to predict a rise and fall in viscosity during embryonic development. Thus, our rapid capillary pressure-driven micro-channel revealed the Newtonian fluid behavior of zebrafish blood at high shear rates and the dynamic viscosity during development.

  16. The Lethality Test System

    NASA Astrophysics Data System (ADS)

    Parsons, W. M.; Sims, J. R.; Parker, J. V.

    1986-11-01

    The Lethality Test System (LTS) under construction at Los Alamos is an electromagnetic launcher facility designed to perform impact experiments at velocities up to 15 km/sec. The launcher is a 25 mm round bore, plasma armature railgun 22 m in length. Preinjection is accomplished with a two-stage light gas gun capable of 7 km/sec. The railgun power supply utilizes traction motors, vacuum interrupters, and pulse transformers. An assembly of 28 traction motors, equipped with flywheels, stores approximately 80 MJ at 92 percent of full speed and energizes the primary windings of three pulse transformers at a current of 50 kA. At peak current an array of vacuum interrupters disconnects the transformer primary windings and forces the current to flow in the secondary windings. The secondary windings are connected to the railgun, and by staging the vacuum interrupter openings, a 1-1.3 MA ramped current waveform will be delivered to the railgun.

  17. Alert dwell time: introduction of a measure to evaluate interruptive clinical decision support alerts

    PubMed Central

    McDaniel, Robert B; Burlison, Jonathan D; Baker, Donald K; Hasan, Murad; Robertson, Jennifer; Hartford, Christine; Howard, Scott C; Sablauer, Andras

    2016-01-01

    Metrics for evaluating interruptive prescribing alerts have many limitations. Additional methods are needed to identify opportunities to improve alerting systems and prevent alert fatigue. In this study, the authors determined whether alert dwell time—the time elapsed from when an interruptive alert is generated to when it is dismissed—could be calculated by using historical alert data from log files. Drug–drug interaction (DDI) alerts from 3 years of electronic health record data were queried. Alert dwell time was calculated for 25,965 alerts, including 777 unique DDIs. The median alert dwell time was 8 s (range, 1–4913 s). Resident physicians had longer median alert dwell times than other prescribers (P < .001). The 10 most frequent DDI alerts (n = 8759 alerts) had shorter median dwell times than alerts that only occurred once (P < .001). This metric can be used in future research to evaluate the effectiveness and efficiency of interruptive prescribing alerts. PMID:26499101

  18. Influence of residual plasma drift velocity on the post-arc sheath expansion of vacuum circuit breakers

    NASA Astrophysics Data System (ADS)

    Mo, Yongpeng; Shi, Zongqian; Bai, Zhibin; Jia, Shenli; Wang, Lijun

    2016-05-01

    The residual plasma in the inter-contact region of a vacuum circuit breaker moves towards the post-arc cathode at current zero, because the residual plasma mainly comes from the cathode spots during the arc burning process. In the most previous theoretical researches on the post-arc sheath expansion process of vacuum circuit breakers, only the thermal motion of residual plasma was taken into consideration. Alternately, the residual plasma was even assumed to be static at the moment of current zero in some simplified models. However, the influence of residual plasma drift velocity at current zero on the post-arc sheath expansion process was rarely investigated. In this paper, this effect is investigated by a one-dimensional particle-in-cell model. Simulation results indicate that the sheath expands slower with higher residual plasma drift velocity in the initial sheath expansion stage. However, with the increase of residual plasma drift velocity, the overall plasma density in the inter-contact region decreases faster, and the sheath expansion velocity increases earlier. Consequently, as a whole, it needs shorter time to expel the residual plasma from the inter-contact region. Furthermore, if the residual plasma drift velocity is high enough, the sheath expansion process ceases before it develops to the post-arc anode. Besides, the influence of the collisions between charges and neutrals is investigated as well in terms of the density of metal vapor. It shows that the residual plasma drift velocity takes remarkable effect only if the density of the metal vapor is relatively low, which corresponds to the circumstance of low-current interruptions.

  19. Fate of electroweak vacuum during preheating

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ema, Yohei; Mukaida, Kyohei; Nakayama, Kazunori

    2016-10-28

    Our electroweak vacuum may be metastable in light of the current experimental data of the Higgs/top quark mass. If this is really the case, high-scale inflation models require a stabilization mechanism of our vacuum during inflation. A possible candidate is the Higgs-inflaton/-curvature coupling because it induces an additional mass term to the Higgs during the slow roll regime. However, after inflation, the additional mass term oscillates, and it can destabilize our electroweak vacuum via production of large Higgs fluctuations during the inflaton oscillation era. In this paper, we study whether or not the Higgs-inflaton/-curvature coupling can save our vacuum bymore » properly taking account of Higgs production during the preheating stage. We put upper bounds on the Higgs-inflaton and -curvature couplings, and discuss possible dynamics that might relax them.« less

  20. The interrupted serosubmucosal anastomosis - still the gold standard.

    PubMed

    Leslie, A; Steele, R J C

    2003-07-01

    The single-layer appositional serosubmucosal anastomosis is a well established technique and appears to have a favourable record. Over a 15-year period the senior author of this paper has performed or directly supervised 553 anastomoses using this technique. This report describes the results of these operations, the results of stapled anastomoses carried out during the same period and discusses the utility of the handsewn technique. From August 1986 to July 2001, 553 intestinal anastomoses in 550 patients were fashioned using single-layer, interrupted serosubmucosal 3/0 braided polyamide and 131 anastomoses in 131 patients were performed using a circular anastomosing stapler. One anastomotic leakage occurred in the group of patients whose anastomosis was handsewn (0.2%) and 11 leaks occurred in those who had a stapled anastomoses (8.4%). The mortality rate in each group was similar (2% and 2.3%, respectively). There were no deaths attributable to anastomotic dehiscence in either group. In this prospectively audited series of 553 handsewn anastomoses the leakage rate was 0.2%. These results compare favourably with other published series and continue to support a single layer of interrupted serosubmucosal sutures as the gold standard for anastomoses involving the large or small bowel.

  1. Series and parallel arc-fault circuit interrupter tests.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Jay Dean; Fresquez, Armando J.; Gudgel, Bob

    2013-07-01

    While the 2011 National Electrical Codeª (NEC) only requires series arc-fault protection, some arc-fault circuit interrupter (AFCI) manufacturers are designing products to detect and mitigate both series and parallel arc-faults. Sandia National Laboratories (SNL) has extensively investigated the electrical differences of series and parallel arc-faults and has offered possible classification and mitigation solutions. As part of this effort, Sandia National Laboratories has collaborated with MidNite Solar to create and test a 24-string combiner box with an AFCI which detects, differentiates, and de-energizes series and parallel arc-faults. In the case of the MidNite AFCI prototype, series arc-faults are mitigated by openingmore » the PV strings, whereas parallel arc-faults are mitigated by shorting the array. A range of different experimental series and parallel arc-fault tests with the MidNite combiner box were performed at the Distributed Energy Technologies Laboratory (DETL) at SNL in Albuquerque, NM. In all the tests, the prototype de-energized the arc-faults in the time period required by the arc-fault circuit interrupt testing standard, UL 1699B. The experimental tests confirm series and parallel arc-faults can be successfully mitigated with a combiner box-integrated solution.« less

  2. Short-Term Health-Related Quality of Life of Critically Ill Children Following Daily Sedation Interruption.

    PubMed

    Vet, Nienke J; de Wildt, Saskia N; Verlaat, Carin W M; Mooij, Miriam G; Tibboel, Dick; de Hoog, Matthijs; Buysse, Corinne M P

    2016-11-01

    Our earlier pediatric daily sedation interruption trial showed that daily sedation interruption in addition to protocolized sedation in critically ill children does not reduce duration of mechanical ventilation, length of stay, or amounts of sedative drugs administered when compared with protocolized sedation only, but undersedation was more frequent in the daily sedation interruption + protocolized sedation group. We now report the preplanned analysis comparing short-term health-related quality of life and posttraumatic stress symptoms between the two groups. Preplanned prospective part of a randomized controlled trial. Two tertiary medical-surgical PICUs in the Netherlands. Critically ill children requiring mechanical ventilation. None. Eight weeks after a child's discharge from the PICU, health-related quality of life was assessed with the validated Child Health Questionnaire and, only for children above 4 years old, posttraumatic stress was assessed with the Dutch Children's Responses to Trauma Inventory. Additionally, health-related quality of life of all study patients was compared with Dutch normative data. Of the 113 patients from two participating centers in the original study, 96 patients were eligible for follow-up and 64 patients were included (response rate, 67%). No difference was found with respect to health-related quality of life between the two study groups. None of the eight children more than 4 years old showed posttraumatic stress symptoms. Daily sedation interruption in addition to protocolized sedation for critically ill children did not seem to have an effect on short-term health-related quality of life. Also in view of the earlier found absence of effect on clinical outcome, we cannot recommend the use of daily sedation interruption + protocolized sedation.

  3. Simulation of the synergistic low Earth orbit effects of vacuum thermal cycling, vacuum UV radiation, and atomic oxygen

    NASA Technical Reports Server (NTRS)

    Dever, Joyce A.; Degroh, Kim K.; Stidham, Curtis R.; Stueber, Thomas J.; Dever, Therese M.; Rodriguez, Elvin; Terlep, Judith A.

    1992-01-01

    In order to assess the low Earth orbit (LEO) durability of candidate space materials, it is necessary to use ground laboratory facilities which provide LEO environmental effects. A facility combining vacuum thermal cycling and vacuum ultraviolet (VUV) radiation has been designed and constructed at NASA Lewis Research Center for this purpose. This facility can also be operated without the VUV lamps. An additional facility can be used to provide VUV exposure only. By utilizing these facilities, followed by atomic oxygen exposure in an RF plasma asher, the effects of the individual vacuum thermal cycling and VUV environments can be compared to the effect of the combined vacuum thermal cycling/VUV environment on the atomic oxygen durability of materials. The synergistic effects of simulated LEO environmental conditions on materials were evaluated by first exposing materials to vacuum thermal cycling, VUV, and vacuum thermal cycling/VUV environments followed by exposure to atomic oxygen in an RP plasma asher. Candidate space power materials such as atomic oxygen protected polyimides and solar concentrator mirrors were evaluated using these facilities. Characteristics of the Vacuum Thermal Cycling/VUV Exposure Facility which simulates the temperature sequences and solar ultraviolet radiation exposure that would be experienced by a spacecraft surface in LEO are discussed. Results of durability evaluations of some candidate space power materials to the simulated LEO environmental conditions will also be discussed. Such results have indicated that for some materials, atomic oxygen durability is affected by previous exposure to thermal cycling and/or VUV exposure.

  4. Nearly Seamless Vacuum-Insulated Boxes

    NASA Technical Reports Server (NTRS)

    Stepanian, Christopher J.; Ou, Danny; Hu, Xiangjun

    2010-01-01

    A design concept, and a fabrication process that would implement the design concept, have been proposed for nearly seamless vacuum-insulated boxes that could be the main structural components of a variety of controlled-temperature containers, including common household refrigerators and insulating containers for shipping foods. In a typical case, a vacuum-insulated box would be shaped like a rectangular parallelepiped conventional refrigerator box having five fully closed sides and a hinged door on the sixth side. Although it is possible to construct the five-closed-side portion of the box as an assembly of five unitary vacuum-insulated panels, it is not desirable to do so because the relatively high thermal conductances of the seams between the panels would contribute significant amounts of heat leakage, relative to the leakage through the panels themselves. In contrast, the proposal would make it possible to reduce heat leakage by constructing the five-closed-side portion of the box plus the stationary portion (if any) of the sixth side as a single, seamless unit; the only remaining seam would be the edge seal around the door. The basic cross-sectional configuration of each side of a vacuum-insulated box according to the proposal would be that of a conventional vacuum-insulated panel: a low-density, porous core material filling a partially evacuated space between face sheets. However, neither the face sheets nor the core would be conventional. The face sheets would be opposite sides of a vacuum bag. The core material would be a flexible polymer-modified silica aerogel of the type described in Silica/Polymer and Silica/Polymer/Fiber Composite Aero - gels (MSC-23736) in this issue of NASA Tech Briefs. As noted in that article, the stiffness of this core material against compression is greater than that of prior aerogels. This is an important advantage because it translates to greater retention of thickness and, hence, of insulation performance when pressure is

  5. Compact vacuum insulation

    DOEpatents

    Benson, D.K.; Potter, T.F.

    1993-01-05

    An ultra-thin compact vacuum insulation panel is comprised of two hard, but bendable metal wall sheets closely spaced apart from each other and welded around the edges to enclose a vacuum chamber. Glass or ceramic spacers hold the wall sheets apart. The spacers can be discrete spherical beads or monolithic sheets of glass or ceramic webs with nodules protruding therefrom to form essentially point'' or line'' contacts with the metal wall sheets. In the case of monolithic spacers that form line'' contacts, two such spacers with the line contacts running perpendicular to each other form effectively point'' contacts at the intersections. Corrugations accommodate bending and expansion, tubular insulated pipes and conduits, and preferred applications are also included.

  6. Compact vacuum insulation

    DOEpatents

    Benson, David K.; Potter, Thomas F.

    1993-01-01

    An ultra-thin compact vacuum insulation panel is comprised of two hard, but bendable metal wall sheets closely spaced apart from each other and welded around the edges to enclose a vacuum chamber. Glass or ceramic spacers hold the wall sheets apart. The spacers can be discrete spherical beads or monolithic sheets of glass or ceramic webs with nodules protruding therefrom to form essentially "point" or "line" contacts with the metal wall sheets. In the case of monolithic spacers that form "line" contacts, two such spacers with the line contacts running perpendicular to each other form effectively "point" contacts at the intersections. Corrugations accommodate bending and expansion, tubular insulated pipes and conduits, and preferred applications are also included.

  7. [Influence of abortions and interruptions of pregnancies on subsequent deliveries. III. After-labor-period and puerperium].

    PubMed

    Knorre, P

    1976-01-01

    In the third stage of labour we must expect an increase of blood lost and placental retentions after preceded interruption. An accumulation of manual detaching of placenta we ascertained for preceded abortion only. In the childbed we found an certained increase of disturbances in uterine involution. We think, that some consequences for medical care in pregnancies, following abortion and interruption, are very important.

  8. Investigating steam penetration using thermometric methods in dental handpieces with narrow internal lumens during sterilizing processes with non-vacuum or vacuum processes.

    PubMed

    Winter, S; Smith, A; Lappin, D; McDonagh, G; Kirk, B

    2017-12-01

    Dental handpieces are required to be sterilized between patient use. Vacuum steam sterilization processes with fractionated pre/post-vacuum phases or unique cycles for specified medical devices are required for hollow instruments with internal lumens to assure successful air removal. Entrapped air will compromise achievement of required sterilization conditions. Many countries and professional organizations still advocate non-vacuum sterilization processes for these devices. To investigate non-vacuum downward/gravity displacement, type-N steam sterilization of dental handpieces, using thermometric methods to measure time to achieve sterilization temperature at different handpiece locations. Measurements at different positions within air turbines were undertaken with thermocouples and data loggers. Two examples of widely used UK benchtop steam sterilizers were tested: a non-vacuum benchtop sterilizer (Little Sister 3; Eschmann, Lancing, UK) and a vacuum benchtop sterilizer (Lisa; W&H, Bürmoos, Austria). Each sterilizer cycle was completed with three handpieces and each cycle in triplicate. A total of 140 measurements inside dental handpiece lumens were recorded. The non-vacuum process failed (time range: 0-150 s) to reliably achieve sterilization temperatures within the time limit specified by the international standard (15 s equilibration time). The measurement point at the base of the handpiece failed in all test runs (N = 9) to meet the standard. No failures were detected with the vacuum steam sterilization type B process with fractionated pre-vacuum and post-vacuum phases. Non-vacuum downward/gravity displacement, type-N steam sterilization processes are unreliable in achieving sterilization conditions inside dental handpieces, and the base of the handpiece is the site most likely to fail. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  9. Study on convection improvement of standard vacuum tube

    NASA Astrophysics Data System (ADS)

    He, J. H.; Du, W. P.; Qi, R. R.; He, J. X.

    2017-11-01

    For the standard all-glass vacuum tube collector, enhancing the vacuum tube axial natural convection can improve its thermal efficiency. According to the study of the standard all-glass vacuum tube, three kinds of guide plates which can inhibit the radial convection and increase axial natural convection are designed, and theory model is established. Experiments were carried out on vacuum tubes with three types of baffles and standard vacuum tubes without the improvement. The results show that T-type guide plate is better than that of Y-type guide plate on restraining convection and increasing axial radial convection effect, Y type is better than that of flat plate type, all guide plates are better than no change; the thermal efficiency of the tube was 2.6% higher than that of the unmodified standard vacuum tube. The efficiency of the system in the experiment can be increased by 3.1%.

  10. 21 CFR 864.9125 - Vacuum-assisted blood collection system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vacuum-assisted blood collection system. 864.9125... Blood and Blood Products § 864.9125 Vacuum-assisted blood collection system. (a) Identification. A vacuum-assisted blood collection system is a device intended for medical purposes that uses a vacuum to...

  11. 21 CFR 864.9125 - Vacuum-assisted blood collection system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Vacuum-assisted blood collection system. 864.9125... Blood and Blood Products § 864.9125 Vacuum-assisted blood collection system. (a) Identification. A vacuum-assisted blood collection system is a device intended for medical purposes that uses a vacuum to...

  12. 21 CFR 864.9125 - Vacuum-assisted blood collection system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Vacuum-assisted blood collection system. 864.9125... Blood and Blood Products § 864.9125 Vacuum-assisted blood collection system. (a) Identification. A vacuum-assisted blood collection system is a device intended for medical purposes that uses a vacuum to...

  13. 21 CFR 864.9125 - Vacuum-assisted blood collection system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Vacuum-assisted blood collection system. 864.9125... Blood and Blood Products § 864.9125 Vacuum-assisted blood collection system. (a) Identification. A vacuum-assisted blood collection system is a device intended for medical purposes that uses a vacuum to...

  14. 21 CFR 864.9125 - Vacuum-assisted blood collection system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Vacuum-assisted blood collection system. 864.9125... Blood and Blood Products § 864.9125 Vacuum-assisted blood collection system. (a) Identification. A vacuum-assisted blood collection system is a device intended for medical purposes that uses a vacuum to...

  15. The trophic vacuum and the evolution of complex life cycles in trophically transmitted helminths

    PubMed Central

    Benesh, Daniel P.; Chubb, James C.; Parker, Geoff A.

    2014-01-01

    Parasitic worms (helminths) frequently have complex life cycles in which they are transmitted trophically between two or more successive hosts. Sexual reproduction often takes place in high trophic-level (TL) vertebrates, where parasites can grow to large sizes with high fecundity. Direct infection of high TL hosts, while advantageous, may be unachievable for parasites constrained to transmit trophically, because helminth propagules are unlikely to be ingested by large predators. Lack of niche overlap between propagule and definitive host (the trophic transmission vacuum) may explain the origin and/or maintenance of intermediate hosts, which overcome this transmission barrier. We show that nematodes infecting high TL definitive hosts tend to have more successive hosts in their life cycles. This relationship was modest, though, driven mainly by the minimum TL of hosts, suggesting that the shortest trophic chains leading to a host define the boundaries of the transmission vacuum. We also show that alternative modes of transmission, like host penetration, allow nematodes to reach high TLs without intermediate hosts. We suggest that widespread omnivory as well as parasite adaptations to increase transmission probably reduce, but do not eliminate, the barriers to the transmission of helminths through the food web. PMID:25209937

  16. Optical diagnostics of the arc plasma using fast intensified CCD-spectrograph system

    NASA Astrophysics Data System (ADS)

    Pavelescu, Gabriela; Guillot, Stephane; Braic, Mariana T.; Hong, Dunpin; Pavelescu, D.; Fleurier, Claude; Braic, Viorel; Gherendi, F.; Dumitrescu, G.; Anghelita, P.; Bauchire, J. M.

    2004-10-01

    Spectroscopic diagnostics, using intensified high speed CCD camera, was applied to study the arc dynamics in low voltage circuit breakers, in vacuum and in air. Time-resolved emission spectroscopy of the vacuum arc plasma, generated during electrode separation, provided information about the interruption process. The investigations were focused on the partial unsuccessful interruption around current zero. Absorption spectroscopy, in a peculiar setup, was used in order to determine the metallic atoms densities in the interelectrode space of a low voltage circuit breaker, working in ambient air.

  17. 14 CFR 25.1433 - Vacuum systems.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Vacuum systems. 25.1433 Section 25.1433 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Miscellaneous Equipment § 25.1433 Vacuum systems. There...

  18. Plates for vacuum thermal fusion

    DOEpatents

    Davidson, James C.; Balch, Joseph W.

    2002-01-01

    A process for effectively bonding arbitrary size or shape substrates. The process incorporates vacuum pull down techniques to ensure uniform surface contact during the bonding process. The essence of the process for bonding substrates, such as glass, plastic, or alloys, etc., which have a moderate melting point with a gradual softening point curve, involves the application of an active vacuum source to evacuate interstices between the substrates while at the same time providing a positive force to hold the parts to be bonded in contact. This enables increasing the temperature of the bonding process to ensure that the softening point has been reached and small void areas are filled and come in contact with the opposing substrate. The process is most effective where at least one of the two plates or substrates contain channels or grooves that can be used to apply vacuum between the plates or substrates during the thermal bonding cycle. Also, it is beneficial to provide a vacuum groove or channel near the perimeter of the plates or substrates to ensure bonding of the perimeter of the plates or substrates and reduce the unbonded regions inside the interior region of the plates or substrates.

  19. Tuberculosis outcomes in Taipei: factors associated with treatment interruption for 2 months and death.

    PubMed

    Chiang, C-Y; Lee, J-J; Yu, M-C; Enarson, D A; Lin, T-P; Luh, K-T

    2009-01-01

    All individuals reported as being treated for pulmonary tuberculosis (PTB) among citizens of Taipei City, Taiwan, in 2003. To investigate risk factors associated with treatment interruption for at least 2 consecutive months and death. The outcome of PTB cases was determined by consulting medical charts. Of 1127 PTB patients registered, 824 (73.1%) were successfully treated, 189 (16.8%) died, 65 (5.8%) interrupted treatment, 17 (1.5%) were still on treatment 15 months after commencing treatment and 32 (2.8%) failed. The only significant factor associated with treatment interruption was visits to other health facilities after commencing tuberculosis (TB) treatment. TB patients had a standardised mortality ratio of 8.7 (95%CI 7.5-10.0). Factors significantly associated with death were age (adjusted hazard ratio [adjHR] 1.06. 95%CI 1.05-1.08), sputum culture not performed/unknown (adjHR 2.07, 95%CI 1.47-2.92), and comorbidity with respiratory disease (adjHR 1.68, 95%CI 1.24-2.27), infectious disease (adjHR 2.80, 95%CI 2.07-3.78), renal disease (adjHR 2.58, 95%CI 1.82-3.66) or cancer (adjHR 3.31, 95%CI 2.35-4.65), compared with other patients. Visits to other health facilities were associated with interruption of treatment for at least 2 months. A high proportion of deaths was due to old age and comorbidity.

  20. A combined intervention to reduce interruptions during medication preparation and double-checking: a pilot-study evaluating the impact of staff training and safety vests.

    PubMed

    Huckels-Baumgart, Saskia; Niederberger, Milena; Manser, Tanja; Meier, Christoph R; Meyer-Massetti, Carla

    2017-10-01

    The aim was to evaluate the impact of staff training and wearing safety vests as a combined intervention on interruptions during medication preparation and double-checking. Interruptions and errors during the medication process are common and an important issue for patient safety in the hospital setting. We performed a pre- and post-intervention pilot-study using direct structured observation of 26 nurses preparing and double-checking 431 medication doses (225 pre-intervention and 206 post-intervention) for 36 patients (21 pre-intervention and 15 post-intervention). With staff training and the introduction of safety vests, the interruption rate during medication preparation was reduced from 36.8 to 28.3 interruptions per hour and during double-checking from 27.5 to 15 interruptions per hour. This pilot-study showed that the frequency of interruptions decreased during the critical tasks of medication preparation and double-checking after the introduction of staff training and wearing safety vests as part of a quality improvement process. Nursing management should acknowledge interruptions as an important factor potentially influencing medication safety. Unnecessary interruptions can be successfully reduced by considering human and system factors and increasing both staff and nursing managers' awareness of 'interruptive communication practices' and implementing physical barriers. This is the first pilot-study specifically evaluating the impact of staff training and wearing safety vests on the reduction of interruptions during medication preparation and double-checking. © 2017 John Wiley & Sons Ltd.

  1. Researches on Position Detection for Vacuum Switch Electrode

    NASA Astrophysics Data System (ADS)

    Dong, Huajun; Guo, Yingjie; Li, Jie; Kong, Yihan

    2018-03-01

    Form and transformation character of vacuum arc is important influencing factor on the vacuum switch performance, and the dynamic separations of electrode is the chief effecting factor on the transformation of vacuum arcs forms. Consequently, how to detect the position of electrode to calculate the separations in the arcs image is of great significance. However, gray level distribution of vacuum arcs image isn’t even, the gray level of burning arcs is high, but the gray level of electrode is low, meanwhile, the forms of vacuum arcs changes sharply, the problems above restrict electrode position detection precisely. In this paper, algorithm of detecting electrode position base on vacuum arcs image was proposed. The digital image processing technology was used in vacuum switch arcs image analysis, the upper edge and lower edge were detected respectively, then linear fitting was done using the result of edge detection, the fitting result was the position of electrode, thus, accurate position detection of electrode was realized. From the experimental results, we can see that: algorithm described in this paper detected upper and lower edge of arcs successfully and the position of electrode was obtained through calculation.

  2. Advanced Photon Source accelerator ultrahigh vacuum guide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, C.; Noonan, J.

    1994-03-01

    In this document the authors summarize the following: (1) an overview of basic concepts of ultrahigh vacuum needed for the APS project, (2) a description of vacuum design and calculations for major parts of APS, including linac, linac waveguide, low energy undulator test line, positron accumulator ring (PAR), booster synchrotron ring, storage ring, and insertion devices, and (3) cleaning procedures of ultrahigh vacuum (UHV) components presently used at APS.

  3. Ceramic vacuum tubes for geothermal well logging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kelly, R.D.

    1977-01-01

    Useful design data acquired in the evaluation of ceramic vacuum tubes for the development of a 500/sup 0/C instrumentation amplifier are presented. The general requirements for ceramic vacuum tubes are discussed for application to the development of high temperature well logs. Commercially available tubes are described and future contract activities that specifically relate to ceramic vacuum tubes are detailed. Supplemental data are presented in the appendix.

  4. 46 CFR 105.10-20 - Pressure vacuum relief valve.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Pressure vacuum relief valve. (a) The term pressure vacuum relief valve means any device or assembly of a mechanical, liquid, weight, or other type used for the automatic regulation of pressure or vacuum in enclosed... 46 Shipping 4 2011-10-01 2011-10-01 false Pressure vacuum relief valve. 105.10-20 Section 105.10...

  5. 46 CFR 105.10-20 - Pressure vacuum relief valve.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Pressure vacuum relief valve. (a) The term pressure vacuum relief valve means any device or assembly of a mechanical, liquid, weight, or other type used for the automatic regulation of pressure or vacuum in enclosed... 46 Shipping 4 2010-10-01 2010-10-01 false Pressure vacuum relief valve. 105.10-20 Section 105.10...

  6. 46 CFR 105.10-20 - Pressure vacuum relief valve.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Pressure vacuum relief valve. (a) The term pressure vacuum relief valve means any device or assembly of a mechanical, liquid, weight, or other type used for the automatic regulation of pressure or vacuum in enclosed... 46 Shipping 4 2014-10-01 2014-10-01 false Pressure vacuum relief valve. 105.10-20 Section 105.10...

  7. 46 CFR 105.10-20 - Pressure vacuum relief valve.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Pressure vacuum relief valve. (a) The term pressure vacuum relief valve means any device or assembly of a mechanical, liquid, weight, or other type used for the automatic regulation of pressure or vacuum in enclosed... 46 Shipping 4 2012-10-01 2012-10-01 false Pressure vacuum relief valve. 105.10-20 Section 105.10...

  8. 46 CFR 105.10-20 - Pressure vacuum relief valve.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Pressure vacuum relief valve. (a) The term pressure vacuum relief valve means any device or assembly of a mechanical, liquid, weight, or other type used for the automatic regulation of pressure or vacuum in enclosed... 46 Shipping 4 2013-10-01 2013-10-01 false Pressure vacuum relief valve. 105.10-20 Section 105.10...

  9. 7 CFR 58.913 - Evaporators and vacuum pans.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Evaporators and vacuum pans. 58.913 Section 58.913....913 Evaporators and vacuum pans. All equipment used in the removal of moisture from milk or milk... Sanitary Standards for Milk and Milk Products Evaporators and Vacuum Pans. ...

  10. 7 CFR 58.913 - Evaporators and vacuum pans.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 3 2014-01-01 2014-01-01 false Evaporators and vacuum pans. 58.913 Section 58.913....913 Evaporators and vacuum pans. All equipment used in the removal of moisture from milk or milk... Sanitary Standards for Milk and Milk Products Evaporators and Vacuum Pans. ...

  11. 7 CFR 58.913 - Evaporators and vacuum pans.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Evaporators and vacuum pans. 58.913 Section 58.913....913 Evaporators and vacuum pans. All equipment used in the removal of moisture from milk or milk... Sanitary Standards for Milk and Milk Products Evaporators and Vacuum Pans. ...

  12. 7 CFR 58.913 - Evaporators and vacuum pans.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Evaporators and vacuum pans. 58.913 Section 58.913....913 Evaporators and vacuum pans. All equipment used in the removal of moisture from milk or milk... Sanitary Standards for Milk and Milk Products Evaporators and Vacuum Pans. ...

  13. 7 CFR 58.913 - Evaporators and vacuum pans.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 3 2012-01-01 2012-01-01 false Evaporators and vacuum pans. 58.913 Section 58.913....913 Evaporators and vacuum pans. All equipment used in the removal of moisture from milk or milk... Sanitary Standards for Milk and Milk Products Evaporators and Vacuum Pans. ...

  14. Vacuum coupling of rotating superconducting rotor

    DOEpatents

    Shoykhet, Boris A.; Zhang, Burt Xudong; Driscoll, David Infante

    2003-12-02

    A rotating coupling allows a vacuum chamber in the rotor of a superconducting electric motor to be continually pumped out. The coupling consists of at least two concentric portions, one of which is allowed to rotate and the other of which is stationary. The coupling is located on the non-drive end of the rotor and is connected to a coolant supply and a vacuum pump. The coupling is smaller in diameter than the shaft of the rotor so that the shaft can be increased in diameter without having to increase the size of the vacuum seal.

  15. Reduction of a linear complex model for respiratory system during Airflow Interruption.

    PubMed

    Jablonski, Ireneusz; Mroczka, Janusz

    2010-01-01

    The paper presents methodology of a complex model reduction to its simpler version - an identifiable inverse model. Its main tool is a numerical procedure of sensitivity analysis (structural and parametric) applied to the forward linear equivalent designed for the conditions of interrupter experiment. Final result - the reduced analog for the interrupter technique is especially worth of notice as it fills a major gap in occlusional measurements, which typically use simple, one- or two-element physical representations. Proposed electrical reduced circuit, being structural combination of resistive, inertial and elastic properties, can be perceived as a candidate for reliable reconstruction and quantification (in the time and frequency domain) of dynamical behavior of the respiratory system in response to a quasi-step excitation by valve closure.

  16. Does interruption of the artery of Adamkiewicz during total en bloc spondylectomy affect neurologic function?

    PubMed

    Murakami, Hideki; Kawahara, Norio; Tomita, Katsuro; Demura, Satoru; Kato, Satoshi; Yoshioka, Katsuhito

    2010-10-15

    A retrospective review of patients with interruption of the artery of Adamkiewicz during total en bloc spondylectomy (TES). To assess neurologic function after interruption of the artery of Adamkiewicz in TES. The most important feeding artery of the thoracolumbar spinal cord is the great anterior radiculomedullary artery, also called the artery of Adamkiewicz. The artery of Adamkiewicz supplies the lower two-thirds of the spinal cord via the anterior spinal artery. It is naturally believed among spine surgeons that interruption of the artery of Adamkiewicz during surgeries is absolutely contraindicated. However, it is necessary to sacrifice the artery of Adamkiewicz during TES, when the tumor, by chance, exists at the level of the artery of Adamkiewicz. Between 1990 and 2009, we have performed 180 cases of TES. All cases except for few emergency cases received preoperative embolization. The artery of Adamkiewicz was verified by angiography of the segmental arteries. There were 15 patients in which the artery of Adamkiewicz was found at the levels of resected vertebrae. Interruption of the artery was performed during surgery in these 15 cases. Neurologic function was analyzed retrospectively. Of the 15 patients, the Frankel grade before surgery was C in 1, D in 5, and E in 9. At follow-up, the Frankel grade was D in 1 and E in 14. There were no cases of neurologic deterioration or paralysis after TES. On the basis of our results of TES on up to 3 vertebrae, interruption of the artery of Adamkiewicz for TES does not adversely affect neurologic function. We advocate strongly that our surgeons are allowed to sacrifice up to 3 pairs of segmental arteries, even including the artery of Adamkiewicz, if necessary.

  17. The Needs of Others: Gender and Sleep Interruptions for Caregivers

    ERIC Educational Resources Information Center

    Burgard, Sarah A.

    2011-01-01

    Received wisdom, some sociological theory and a handful of qualitative studies suggest that the "night shift" of caregiving work that interrupts sleep is a burden borne disproportionately by women. However, there is no broadly representative evidence to substantiate claims about who takes the night shift in contemporary American households.…

  18. Adsorbate-driven morphological changes on Cu(111) nano-pits

    DOE PAGES

    Mudiyanselage, K.; Xu, F.; Hoffmann, F. M.; ...

    2014-12-09

    Adsorbate-driven morphological changes of pitted-Cu(111) surfaces have been investigated following the adsorption and desorption of CO and H. The morphology of the pitted-Cu(111) surfaces, prepared by Ar + sputtering, exposed a few atomic layers deep nested hexagonal pits of diameters from 8 to 38 nm with steep step bundles. The roughness of pitted-Cu(111) surfaces can be healed by heating to 450-500 K in vacuum. Adsorption of CO on the pitted-Cu(111) surface leads to two infrared peaks at 2089-2090 and 2101-2105 cm -1 for CO adsorbed on under-coordinated sites in addition to the peak at 2071 cm -1 for CO adsorbedmore » on atop sites of the close-packed Cu(111) surface. CO adsorbed on under-coordinated sites is thermally more stable than that of atop Cu(111) sites. Annealing of the CO-covered surface from 100 to 300 K leads to minor changes of the surface morphology. In contrast, annealing of a H covered surface to 300 K creates a smooth Cu(111) surface as deduced from infrared data of adsorbed CO and scanning tunnelling microscopy (STM) imaging. The observation of significant adsorbate-driven morphological changes with H is attributed to its stronger modification of the Cu(111) surface by the formation of a sub-surface hydride with a hexagonal structure, which relaxes into the healed Cu(111) surface upon hydrogen desorption. These morphological changes occur ~150 K below the temperature required for healing of the pitted-Cu(111) surface by annealing in vacuum. In contrast, the adsorption of CO, which only interacts with the top-most Cu layer and desorbs by 160 K, does not significantly change the morphology of the pitted-Cu(111) surface.« less

  19. Assessing Motion Induced Interruptions Using a Motion Platform

    DTIC Science & Technology

    2013-09-01

    same way that cars have shock absorbers to decrease jolt from potholes and bumps in the road, ships may have the potential to be designed to better...Integration (HSI) seeks to assure human performance to reduce operating costs. This thesis seeks to develop a model for ship design in relation to Motion...Induced Interruptions (MII). The model is based on the premise that MIIs affect specific domains of HSI in an adverse way. Future ship design

  20. In-Vacuum Dissociator for Atomic-Hydrogen Masers

    NASA Technical Reports Server (NTRS)

    Vessot, R. F.

    1987-01-01

    Thermal control and vacuum sealing achieved while contamination avoided. Simple, relatively inexpensive molecular-hydrogen dissociator for atomic-hydrogen masers used on Earth or in vacuum of space. No air cooling required, and absence of elastomeric O-ring seals prevents contamination. In-vacuum dissociator for atomic hydrogen masers, hydrogen gas in glass dissociator dissociated by radio-frequency signal transmitted from surrounding 3-turn coil. Heat in glass conducted away by contacting metal surfaces.

  1. Vacuum-jacketed transfer line installation technique

    NASA Technical Reports Server (NTRS)

    Bowers, W. M.

    1968-01-01

    Rolling-type spacers in the form of steel balls retained in appropriate sleeves affixed at intervals to the exterior of the transfer line facilitate the installation of a vacuum-jacketed line. They act as standoffs to position the transfer line concentrically within the vacuum jacket line.

  2. Interruption and reduction of Erysiphe necator cleistothecia development utilizing fungicidal oil

    USDA-ARS?s Scientific Manuscript database

    Grape powdery mildew epidemics, caused by Erysiphe necator, are initiated by the release and subsequent germination of ascospores from mature cleistothecia. Interrupting the development of cleistothecia prior to overwintering may reduce or prevent the overwintering of E. necator in vineyards thereby...

  3. Thermodynamic performance of multi-stage gradational lead screw vacuum pump

    NASA Astrophysics Data System (ADS)

    Zhao, Fan; Zhang, Shiwei; Sun, Kun; Zhang, Zhijun

    2018-02-01

    As a kind of dry mechanical vacuum pump, the twin-screw vacuum pump has an outstanding pumping performance during operation, widely used in the semiconductor industry. Compared with the constant lead screw (CLS) vacuum pump, the gradational lead screw (GLS) vacuum pump is more popularly applied in recent years. Nevertheless, not many comparative studies on the thermodynamic performance of GLS vacuum pump can be found in the literature. Our study focuses on one type of GLS vacuum pump, the multi-stage gradational lead screw (MGLS) vacuum pump, gives a detailed description of its construction and illustrates it with the drawing. Based on the structural analysis, the thermodynamic procedure is divided into four distinctive processes, including sucking process, transferring (compressing) process, backlashing process and exhausting process. The internal mechanism of each process is qualitatively illustrated and the mathematical expressions of seven thermodynamic parameters are given under the ideal situation. The performance curves of MGLS vacuum pump are plotted by MATLAB software and compared with those of the CLS vacuum pump in the same case. The results can well explain why the MGLS vacuum pump has more favorable pumping performance than the CLS vacuum pump in saving energy, reducing noise and heat dissipation.

  4. Vacuum tool manipulator

    DOEpatents

    Zollinger, William T.

    1993-01-01

    Apparatus for manipulating a vacuum hose in a reactor vessel comprises a housing with two opposing openings, an arm carried by the housing and deployable from a stowed position essentially completely within the housing to an extended position where the arm extends through the two openings in a generally horizontal position. The arm preferably has a two-fingered gripping device for gripping the vacuum hose but may carry a different end effector such as a grinding wheel. The fingers are opened and closed by one air cylinder. A second air cylinder extends the device. A third air cylinder within the housing pivotally pulls the opposing end of the arm into the housing via a pivoting member pivotally connected between the third air cylinder shaft and the arm.

  5. REVIEWS OF TOPICAL PROBLEMS: Cosmic vacuum

    NASA Astrophysics Data System (ADS)

    Chernin, Artur D.

    2001-11-01

    Recent observational studies of distant supernovae have suggested the existence of cosmic vacuum whose energy density exceeds the total density of all the other energy components in the Universe. The vacuum produces the field of antigravity that causes the cosmological expansion to accelerate. It is this accelerated expansion that has been discovered in the observations. The discovery of cosmic vacuum radically changes our current understanding of the present state of the Universe. It also poses new challenges to both cosmology and fundamental physics. Why is the density of vacuum what it is? Why do the densities of the cosmic energy components differ in exact value but agree in order of magnitude? On the other hand, the discovery made at large cosmological distances of hundreds and thousands Mpc provides new insights into the dynamics of the nearby Universe, the motions of galaxies in the local volume of 10 - 20 Mpc where the cosmological expansion was originally discovered.

  6. Source replenishment device for vacuum deposition

    DOEpatents

    Hill, Ronald A.

    1988-01-01

    A material source replenishment device for use with a vacuum deposition apparatus. The source replenishment device comprises an intermittent motion producing gear arrangement disposed within the vacuum deposition chamber. An elongated rod having one end operably connected to the gearing arrangement is provided with a multiarmed head at the opposite end disposed adjacent the heating element of the vacuum deposition apparatus. An inverted U-shaped source material element is releasably attached to the outer end of each arm member whereby said multiarmed head is moved to locate a first of said material elements above said heating element, whereupon said multiarmed head is lowered to engage said material element with the heating element and further lowered to release said material element on the heating element. After vaporization of said material element, second and subsequent material elements may be provided to the heating element without the need for opening the vacuum deposition apparatus to the atmosphere.

  7. Source replenishment device for vacuum deposition

    DOEpatents

    Hill, R.A.

    1986-05-15

    A material source replenishment device for use with a vacuum deposition apparatus is described. The source replenishment device comprises an intermittent motion producing gear arrangement disposed within the vacuum deposition chamber. An elongated rod having one end operably connected to the gearing arrangement is provided with a multiarmed head at the opposite end disposed adjacent the heating element of the vacuum deposition apparatus. An inverted U-shaped source material element is releasably attached to the outer end of each arm member whereby said multiarmed head is moved to locate a first of said material elements above said heating element, whereupon said multiarmed head is lowered to engage said material element with the heating element and further lowered to release said material element on the heating element. After vaporization of said material element, second and subsequent material elements may be provided to the heating element without the need for opening the vacuum deposition apparatus to the atmosphere.

  8. Waveguide quantum electrodynamics in squeezed vacuum

    NASA Astrophysics Data System (ADS)

    You, Jieyu; Liao, Zeyang; Li, Sheng-Wen; Zubairy, M. Suhail

    2018-02-01

    We study the dynamics of a general multiemitter system coupled to the squeezed vacuum reservoir and derive a master equation for this system based on the Weisskopf-Wigner approximation. In this theory, we include the effect of positions of the squeezing sources which is usually neglected in the previous studies. We apply this theory to a quasi-one-dimensional waveguide case where the squeezing in one dimension is experimentally achievable. We show that while dipole-dipole interaction induced by ordinary vacuum depends on the emitter separation, the two-photon process due to the squeezed vacuum depends on the positions of the emitters with respect to the squeezing sources. The dephasing rate, decay rate, and the resonance fluorescence of the waveguide-QED in the squeezed vacuum are controllable by changing the positions of emitters. Furthermore, we demonstrate that the stationary maximum entangled NOON state for identical emitters can be reached with arbitrary initial state when the center-of-mass position of the emitters satisfies certain conditions.

  9. Sugar maple sap volume increases as vacuum level is increased

    Treesearch

    Russell S. Walters; H. Clay Smith

    1975-01-01

    Maple sap yields collected by using plastic tubing with a vacuum pump increased as the vacuum level was increased. Sap volumes collected at the 10- and 15-inch mercury vacuum levels were statistically significantly higher than volumes collected at the 5-inch level. Although the 15-inch vacuum yielded more sap than the 10-inch vacuum, the difference was not...

  10. Outgassing of solid material into vacuum thermal insulation spaces

    NASA Technical Reports Server (NTRS)

    Wang, Pao-Lien

    1994-01-01

    Many cryogenic storage tanks use vacuum between inner and outer tank for thermal insulation. These cryogenic tanks also use a radiation shield barrier in the vacuum space to prevent radiation heat transfer. This shield is usually constructed by using multiple wraps of aluminized mylar and glass paper as inserts. For obtaining maximum thermal performance, a good vacuum level must be maintained with the insulation system. It has been found that over a period of time solid insulation materials will vaporize into the vacuum space and the vacuum will degrade. In order to determine the degradation of vacuum, the rate of outgassing of the insulation materials must be determined. Outgassing rate of several insulation materials obtained from literature search were listed in tabular form.

  11. An online, energy-resolving beam profile detector for laser-driven proton beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Metzkes, J.; Rehwald, M.; Obst, L.

    In this paper, a scintillator-based online beam profile detector for the characterization of laser-driven proton beams is presented. Using a pixelated matrix with varying absorber thicknesses, the proton beam is spatially resolved in two dimensions and simultaneously energy-resolved. A thin plastic scintillator placed behind the absorber and read out by a CCD camera is used as the active detector material. The spatial detector resolution reaches down to ∼4 mm and the detector can resolve proton beam profiles for up to 9 proton threshold energies. With these detector design parameters, the spatial characteristics of the proton distribution and its cut-off energymore » can be analyzed online and on-shot under vacuum conditions. The paper discusses the detector design, its characterization and calibration at a conventional proton source, as well as the first detector application at a laser-driven proton source.« less

  12. Motivational priming and processing interrupt: startle reflex modulation during shallow and deep processing of emotional words.

    PubMed

    Herbert, Cornelia; Kissler, Johanna

    2010-05-01

    Valence-driven modulation of the startle reflex, that is larger eyeblinks during viewing of unpleasant pictures and inhibited blinks while viewing pleasant pictures, is well documented. The current study investigated, whether this motivational priming pattern also occurs during processing of unpleasant and pleasant words, and to what extent it is influenced by shallow vs. deep encoding of verbal stimuli. Emotional and neutral adjectives were presented for 5s, and the acoustically elicited startle eyeblink response was measured while subjects memorized the words by means of shallow or deep processing strategies. Results showed blink potentiation to unpleasant and blink inhibition to pleasant adjectives in subjects using shallow encoding strategies. In subjects using deep-encoding strategies, blinks were larger for pleasant than unpleasant or neutral adjectives. In line with this, free recall of pleasant words was also better in subjects who engaged in deep processing. The results suggest that motivational priming holds as long as processing is perceptual. However, during deep processing the startle reflex appears to represent a measure of "processing interrupt", facilitating blinks to those stimuli that are more deeply encoded. Copyright 2010 Elsevier B.V. All rights reserved.

  13. Mass spectrometer vacuum housing and pumping system

    DOEpatents

    Coutts, G.W.; Bushman, J.F.; Alger, T.W.

    1996-07-23

    A vacuum housing and pumping system is described for a portable gas chromatograph/mass spectrometer (GC/MS). The vacuum housing section of the system has minimum weight for portability while designed and constructed to utilize metal gasket sealed stainless steel to be compatible with high vacuum operation. The vacuum pumping section of the system consists of a sorption (getter) pump to remove atmospheric leakage and outgassing contaminants as well as the gas chromatograph carrier gas (hydrogen) and an ion pump to remove the argon from atmospheric leaks. The overall GC/MS system has broad application to contaminants, hazardous materials, illegal drugs, pollution monitoring, etc., as well as for use by chemical weapon treaty verification teams, due to the light weight and portability thereof. 7 figs.

  14. Mass spectrometer vacuum housing and pumping system

    DOEpatents

    Coutts, Gerald W.; Bushman, John F.; Alger, Terry W.

    1996-01-01

    A vacuum housing and pumping system for a portable gas chromatograph/mass spectrometer (GC/MS). The vacuum housing section of the system has minimum weight for portability while designed and constructed to utilize metal gasket sealed stainless steel to be compatible with high vacuum operation. The vacuum pumping section of the system consists of a sorption (getter) pump to remove atmospheric leakage and outgassing contaminants as well as the gas chromatograph carrier gas (hydrogen) and an ion pump to remove the argon from atmospheric leaks. The overall GC/MS system has broad application to contaminants, hazardous materials, illegal drugs, pollution monitoring, etc., as well as for use by chemical weapon treaty verification teams, due to the light weight and portability thereof.

  15. Enhancing the Simulation Speed of Sensor Network Applications by Asynchronization of Interrupt Service Routines

    PubMed Central

    Joe, Hyunwoo; Woo, Duk-Kyun; Kim, Hyungshin

    2013-01-01

    Sensor network simulations require high fidelity and timing accuracy to be used as an implementation and evaluation tool. The cycle-accurate and instruction-level simulator is the known solution for these purposes. However, this type of simulation incurs a high computation cost since it has to model not only the instruction level behavior but also the synchronization between multiple sensors for their causality. This paper presents a novel technique that exploits asynchronous simulations of interrupt service routines (ISR). We can avoid the synchronization overheads when the interrupt service routines are simulated without preemption. If the causality errors occur, we devise a rollback procedure to restore the original synchronized simulation. This concept can be extended to any instruction-level sensor network simulator. Evaluation results show our method can enhance the simulation speed up to 52% in the case of our experiments. For applications with longer interrupt service routines and smaller number of preemptions, the speedup becomes greater. In addition, our simulator is 2 to 11 times faster than the well-known sensor network simulator. PMID:23966200

  16. Operational Failures and Interruptions in Hospital Nursing

    PubMed Central

    Tucker, Anita L; Spear, Steven J

    2006-01-01

    Objective To describe the work environment of hospital nurses with particular focus on the performance of work systems supplying information, materials, and equipment for patient care. Data Sources Primary observation, semistructured interviews, and surveys of hospital nurses. Study Design We sampled a cross-sectional group of six U.S. hospitals to examine the frequency of work system failures and their impact on nurse productivity. Data Collection We collected minute-by-minute data on the activities of 11 nurses. In addition, we conducted interviews with six of these nurses using questions related to obstacles to care. Finally, we created and administered two surveys in 48 nursing units, one for nurses and one for managers, asking about the frequency of specific work system failures. Principal Findings Nurses we observed experienced an average of 8.4 work system failures per 8-hour shift. The five most frequent types of failures, accounting for 6.4 of these obstacles, involved medications, orders, supplies, staffing, and equipment. Survey questions asking nurses how frequently they experienced these five categories of obstacles yielded similar frequencies. For an average 8-hour shift, the average task time was only 3.1 minutes, and in spite of this, nurses were interrupted mid-task an average of eight times per shift. Conclusions Our findings suggest that nurse effectiveness can be increased by creating improvement processes triggered by the occurrence of work system failures, with the goal of reducing future occurrences. Second, given that nursing work is fragmented and unpredictable, designing processes that are robust to interruption can help prevent errors. PMID:16704505

  17. Viability of Cladosporium herbarum spores under 157 nm laser and vacuum ultraviolet irradiation, low temperature (10 K) and vacuum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sarantopoulou, E., E-mail: esarant@eie.gr; Stefi, A.; Kollia, Z.

    Ultraviolet photons can damage microorganisms, which rarely survive prolonged irradiation. In addition to the need for intact DNA, cell viability is directly linked to the functionality of the cell wall and membrane. In this work, Cladosporium herbarum spore monolayers exhibit high viability (7%) when exposed to 157 nm laser irradiation (412 kJm⁻²) or vacuum-ultraviolet irradiation (110–180 nm) under standard pressure and temperature in a nitrogen atmosphere. Spore viability can be determined by atomic-force microscopy, nano-indentation, mass, μ-Raman and attenuated reflectance Fourier-transform far-infrared spectroscopies and DNA electrophoresis. Vacuum ultraviolet photons cause molecular damage to the cell wall, but radiation resistance inmore » spores arises from the activation of a photon-triggered signaling reaction, expressed via the exudation of intracellular substances, which, in combination with the low penetration depth of vacuum-ultraviolet photons, shields DNA from radiation. Resistance to phototoxicity under standard conditions was assessed, as was resistance to additional environmental stresses, including exposure in a vacuum, under different rates of change of pressure during pumping time and low (10 K) temperatures. Vacuum conditions were far more destructive to spores than vacuum-ultraviolet irradiation, and UV-B photons were two orders of magnitude more damaging than vacuum-ultraviolet photons. The viability of irradiated spores was also enhanced at 10 K. This work, in addition to contributing to the photonic control of the viability of microorganisms exposed under extreme conditions, including decontamination of biological warfare agents, outlines the basis for identifying bio-signaling in vivo using physical methodologies.« less

  18. The Impact of Motion Induced Interruptions on Cognitive Performance

    DTIC Science & Technology

    2014-07-23

    found that even participants presenting with minor physiological effects of motion experienced a decline in multitasking performance. Further, Yu...literature has investigated the impact of task based interruptions such as being inter- rupted by a phone call or writing an email . In these...Engineers Journal. 102 (2) 65-72. Matsangas, P. (2013). The Effect of Mild Motion Sickness and Sopite Syndrome on Multitasking Cognitive Performance

  19. Highly precise and compact ultrahigh vacuum rotary feedthrough.

    PubMed

    Aiura, Y; Kitano, K

    2012-03-01

    The precision and rigidity of compact ultrahigh vacuum (UHV) rotary feedthroughs were substantially improved by preparing and installing an optimal crossed roller bearing with mounting holes. Since there are mounting holes on both the outer and inner races, the bearing can be mounted directly to rotary and stationary stages without any fixing plates and housing. As a result, it is possible to increase the thickness of the bearing or the size of the rolling elements in the bearing without increasing the distance between the rotating and fixing International Conflat flanges of the UHV rotary feedthrough. Larger rolling elements enhance the rigidity of the UHV rotary feedthrough. Moreover, owing to the structure having integrated inner and outer races and mounting holes, the performance is almost entirely unaffected by the installation of the bearing, allowing for a precise optical encoder to be installed in the compact UHV rotary feedthrough. Using position feedback via a worm gear system driven by a stepper motor and a precise rotary encoder, the actual angle of the compact UHV rotary feedthrough can be controlled with extremely high precision.

  20. Highly precise and compact ultrahigh vacuum rotary feedthrough

    NASA Astrophysics Data System (ADS)

    Aiura, Y.; Kitano, K.

    2012-03-01

    The precision and rigidity of compact ultrahigh vacuum (UHV) rotary feedthroughs were substantially improved by preparing and installing an optimal crossed roller bearing with mounting holes. Since there are mounting holes on both the outer and inner races, the bearing can be mounted directly to rotary and stationary stages without any fixing plates and housing. As a result, it is possible to increase the thickness of the bearing or the size of the rolling elements in the bearing without increasing the distance between the rotating and fixing International Conflat flanges of the UHV rotary feedthrough. Larger rolling elements enhance the rigidity of the UHV rotary feedthrough. Moreover, owing to the structure having integrated inner and outer races and mounting holes, the performance is almost entirely unaffected by the installation of the bearing, allowing for a precise optical encoder to be installed in the compact UHV rotary feedthrough. Using position feedback via a worm gear system driven by a stepper motor and a precise rotary encoder, the actual angle of the compact UHV rotary feedthrough can be controlled with extremely high precision.

  1. Randomized, Controlled Trial of Therapy Interruption in Chronic HIV-1 Infection

    PubMed Central

    Papasavvas, Emmanouil; Kostman, Jay R; Mounzer, Karam; Grant, Robert M; Gross, Robert; Gallo, Cele; Azzoni, Livio; Foulkes, Andrea; Thiel, Brian; Pistilli, Maxwell; Mackiewicz, Agnieszka; Shull, Jane; Montaner, Luis J

    2004-01-01

    Background Approaches to limiting exposure to antiretroviral therapy (ART) drugs are an active area of HIV therapy research. Here we present longitudinal follow-up of a randomized, open-label, single-center study of the immune, viral, and safety outcomes of structured therapy interruptions (TIs) in patients with chronically suppressed HIV-1 infection as compared to equal follow-up of patients on continuous therapy and including a final therapy interruption in both arms. Methods and Findings Forty-two chronically HIV-infected patients on suppressive ART with CD4 counts higher than 400 were randomized 1:1 to either (1) three successive fixed TIs of 2, 4, and 6 wk, with intervening resumption of therapy with resuppression for 4 wk before subsequent interruption, or (2) 40 wk of continuous therapy, with a final open-ended TI in both treatment groups. Main outcome was analysis of the time to viral rebound (>5,000 copies/ml) during the open-ended TI. Secondary outcomes included study-defined safety criteria, viral resistance, therapy failure, and retention of immune reconstitution. There was no difference between the groups in time to viral rebound during the open-ended TI (continuous therapy/single TI, median [interquartile range] = 4 [1–8] wk, n = 21; repeated TI, median [interquartile range] = 5 [4–8] wk, n = 21; p = 0.36). No differences in study-related adverse events, viral set point at 12 or 20 wk of open-ended interruption, viral resistance or therapy failure, retention of CD4 T cell numbers on ART, or retention of lymphoproliferative recall antigen responses were noted between groups. Importantly, resistance detected shortly after initial viremia following the open-ended TI did not result in a lack of resuppression to less than 50 copies/ml after reinitiation of the same drug regimen. Conclusion Cycles of 2- to 6-wk time-fixed TIs in patients with suppressed HIV infection failed to confer a clinically significant benefit with regard to viral suppression off

  2. Task errors by emergency physicians are associated with interruptions, multitasking, fatigue and working memory capacity: a prospective, direct observation study.

    PubMed

    Westbrook, Johanna I; Raban, Magdalena Z; Walter, Scott R; Douglas, Heather

    2018-01-09

    Interruptions and multitasking have been demonstrated in experimental studies to reduce individuals' task performance. These behaviours are frequently used by clinicians in high-workload, dynamic clinical environments, yet their effects have rarely been studied. To assess the relative contributions of interruptions and multitasking by emergency physicians to prescribing errors. 36 emergency physicians were shadowed over 120 hours. All tasks, interruptions and instances of multitasking were recorded. Physicians' working memory capacity (WMC) and preference for multitasking were assessed using the Operation Span Task (OSPAN) and Inventory of Polychronic Values. Following observation, physicians were asked about their sleep in the previous 24 hours. Prescribing errors were used as a measure of task performance. We performed multivariate analysis of prescribing error rates to determine associations with interruptions and multitasking, also considering physician seniority, age, psychometric measures, workload and sleep. Physicians experienced 7.9 interruptions/hour. 28 clinicians were observed prescribing 239 medication orders which contained 208 prescribing errors. While prescribing, clinicians were interrupted 9.4 times/hour. Error rates increased significantly if physicians were interrupted (rate ratio (RR) 2.82; 95% CI 1.23 to 6.49) or multitasked (RR 1.86; 95% CI 1.35 to 2.56) while prescribing. Having below-average sleep showed a >15-fold increase in clinical error rate (RR 16.44; 95% CI 4.84 to 55.81). WMC was protective against errors; for every 10-point increase on the 75-point OSPAN, a 19% decrease in prescribing errors was observed. There was no effect of polychronicity, workload, physician gender or above-average sleep on error rates. Interruptions, multitasking and poor sleep were associated with significantly increased rates of prescribing errors among emergency physicians. WMC mitigated the negative influence of these factors to an extent. These

  3. Main Vacuum Technical Issues of Evacuated Tube Transportation

    NASA Astrophysics Data System (ADS)

    Zhang, Y. P.; Li, S. S.; Wang, M. X.

    In the future, Evacuated Tube Transportation (ETT) would be built and faster than jets. ETT tube with diameter 2∼4m and length over 1000 km will be the largest scale vacuum equipment on earth. This paper listed some main vacuum technical issues to be solved in ETT as follow. How to build ultra-large-scale vacuum chamber like ETT tube with low cost and high reliability? How to pump gas out off the ETT tube in short time? How to release heat or reduce temperature in the vacuum tube? Hot to avoid vacuum electricity discharge? How to manufacture vehicles with airproof shells and equip the life support system? How to detect leakage and find leakage position efficiently and fast as possible? Some relative solutions and suggestions are put up.

  4. Vacuum deposition and curing of liquid monomers apparatus

    DOEpatents

    Affinito, John D.

    1996-01-01

    The present invention is the formation of solid polymer layers under vacuum. More specifically, the present invention is the use of "standard" polymer layer-making equipment that is generally used in an atmospheric environment in a vacuum, and degassing the monomer material prior to injection into the vacuum. Additional layers of polymer or metal or oxide may be vacuum deposited onto solid polymer layers. Formation of polymer layers under a vacuum improves material and surface characteristics, and subsequent quality of bonding to additional layers. Further advantages include use of less to no photoinitiator for curing, faster curing, fewer impurities in the polymer electrolyte, as well as improvement in material properties including no trapped gas resulting in greater density, and reduced monomer wetting angle that facilitates spreading of the monomer and provides a smoother finished surface.

  5. Role of contextual cues on the perception of spectrally reduced interrupted speech.

    PubMed

    Patro, Chhayakanta; Mendel, Lisa Lucks

    2016-08-01

    Understanding speech within an auditory scene is constantly challenged by interfering noise in suboptimal listening environments when noise hinders the continuity of the speech stream. In such instances, a typical auditory-cognitive system perceptually integrates available speech information and "fills in" missing information in the light of semantic context. However, individuals with cochlear implants (CIs) find it difficult and effortful to understand interrupted speech compared to their normal hearing counterparts. This inefficiency in perceptual integration of speech could be attributed to further degradations in the spectral-temporal domain imposed by CIs making it difficult to utilize the contextual evidence effectively. To address these issues, 20 normal hearing adults listened to speech that was spectrally reduced and spectrally reduced interrupted in a manner similar to CI processing. The Revised Speech Perception in Noise test, which includes contextually rich and contextually poor sentences, was used to evaluate the influence of semantic context on speech perception. Results indicated that listeners benefited more from semantic context when they listened to spectrally reduced speech alone. For the spectrally reduced interrupted speech, contextual information was not as helpful under significant spectral reductions, but became beneficial as the spectral resolution improved. These results suggest top-down processing facilitates speech perception up to a point, and it fails to facilitate speech understanding when the speech signals are significantly degraded.

  6. Neonatal repair of right interrupted aortic arch with cerebro-myocardial perfusion technique.

    PubMed

    Takeuchi, Koh; Masuzawa, Akihiro; Kobayashi, Jotaro; Tsuchiya, Keiji

    2011-10-01

    Right interrupted aortic arch and descending aorta is exceedingly rare and most likely cause respiratory presentation, since patent ductus arteriosus (PDA) courses over the right mainstem bronchus. We report a case of successful neonatal biventricular repair of a right interrupted aortic arch (type B), with an aberrant right subclavian artery ventricular septal defect (VSD) in a 2.7 kg term neonate with DiGeorge syndrome. Patient presented in severe respiratory distress and acidosis at one day old. Two-dimensional (2D) echocardiography revealed aortic arch interruption beyond the common carotid arteries with large perimembranous outlet VSD. Aortic annulus diameter was 4.8 mm and there was no left ventricle (LV) outflow tract obstruction. Three-dimensional (3D) CT-scan confirmed these findings and identified a right-sided ductal arch that continued over the right mainstem bronchus into a right-sided descending aorta and aberrant right subclavian artery. Brachiocephalic perfusion and ductal perfusion was employed for cooling during cardiopulmonary bypass. Under deep hypothermia (27 °C rectal temperature), selective cerebro-myocardial perfusion was used for successful aortic arch repair without sacrificing the aberrant right subclavian artery. A direct tension-free anastomosis was attained. Her postoperative course was uneventful and her respiratory symptoms disappeared postoperatively. Early surgical correction is mandatory for these patients with unique anatomy and presentation.

  7. Development of a MEMS-Scale Turbomachinery Based Vacuum Pump

    DTIC Science & Technology

    2012-06-01

    MEMS -SCALE TURBOMACHINERY BASED VACUUM PUMP by Michael J. Shea June 2012 Thesis Advisor: Anthony J. Gannon Second Reader...June 2012 3. REPORT TYPE AND DATES COVERED Master’s Thesis 4. TITLE AND SUBTITLE Development of a MEMS -Scale Turbomachinery Based Vacuum Pump 5...to develop a MEMS scale turbomachinery based vacuum pump. This would allow very high vacuum to be drawn for handheld mass spectroscopy. This

  8. Vacuum system for the SAMURAI spectrometer

    NASA Astrophysics Data System (ADS)

    Shimizu, Y.; Otsu, H.; Kobayashi, T.; Kubo, T.; Motobayashi, T.; Sato, H.; Yoneda, K.

    2013-12-01

    The first commissioning experiment of the SAMURAI spectrometer and its beam line was performed in March, 2012. The vacuum system for the SAMURAI spectrometer includes its beam line and the SAMURAI vacuum chamber with the windows for detecting neutrons and charged particles. The window for neutrons was made of stainless steel with a thickness of 3 mm and was designed with a shape of partial cylinder to support itself against the atmospheric pressure. The window for charged particles was of the combination of Kevlar and Mylar with the thickness of 280 and 75 μm, respectively. The pressure in the vacuum system was at a few Pa throughout the commissioning experiment.

  9. Moving characteristics of electrodes for vacuum circuit breaker

    NASA Astrophysics Data System (ADS)

    Yuan, Shun; Wang, Jimei

    1994-05-01

    This paper analyzes the effect of the gap of electrodes on the state of vacuum arc by experiment and theory. And the model of vacuum arc is set up. The optimal gap can be deduced from controlling the vacuum arc to be diffusion state, in order to get the optimal moving characteristics of electrodes.

  10. Three stage vacuum system for ultralow temperature installation

    NASA Astrophysics Data System (ADS)

    Das, N. K.; Pradhan, J.; Naser, Md Z. A.; Mandal, B. Ch; Roy, A.; Kumar, P.; Mallik, C.; Bhandari, R. K.

    2012-11-01

    We use a three stage vacuum system for developing a dilution fridge at VECC, Kolkata. We aim at achieving a cooling power of 20μW at 100mK for various experiments especially in the field of condensed matter and nuclear physics. The system is essentially composed of four segments-bath cryostat, vacuum system, dilution insert and 3He circulation circuit. Requirement of vacuum system at different stages are different. The vacuum system for cryostat and for internal vacuum chamber located within the helium bath is a common turbo molecular pump backed by scroll pump as to maintain a vacuum ~10-6mbar. For bringing down the temperature of the helium evaporator, we use a high throughput Roots pump backed by a dry pump. The pumping system for 3He distillation chamber (still) requires a high pumping speed, so a turbo drag pump backed by a scroll pump has been installed. As the fridge use precious 3He gas for operation, the entire system has been made to be absolutely leak proof with respect to the 3He gas.

  11. Carbon nanotubes based vacuum gauge

    NASA Astrophysics Data System (ADS)

    Rudyk, N. N.; Il'in, O. I.; Il'ina, M. V.; Fedotov, A. A.; Klimin, V. S.; Ageev, O. A.

    2017-11-01

    We have created an ionization type Vacuum gauge with sensor element based on an array of vertically aligned carbon nanotubes. Obtained asymmetrical current-voltage characteristics at different voltage polarity on the electrode with the CNTs. It was found that when applying a negative potential on an electrode with the CNTs, the current in the gap is higher than at a positive potential. In the pressure range of 1 ÷ 103 Torr vacuum gauge sensitivity was 6 mV/Torr (at a current of 4.5·10-5 A) and in the range of 10-5 ÷ 1 Torr was 10 mV/Torr (at a current of 1.3·10-5 A). It is shown that the energy efficiency of vacuum gauge can be increased in the case where electrode with CNT operates as an emitter of electrons.

  12. Baryogenesis in false vacuum

    NASA Astrophysics Data System (ADS)

    Hamada, Yuta; Yamada, Masatoshi

    2017-09-01

    The null result in the LHC may indicate that the standard model is not drastically modified up to very high scales, such as the GUT/string scale. Having this in the mind, we suggest a novel leptogenesis scenario realized in the false vacuum of the Higgs field. If the Higgs field develops a large vacuum expectation value in the early universe, a lepton number violating process is enhanced, which we use for baryogenesis. To demonstrate the scenario, several models are discussed. For example, we show that the observed baryon asymmetry is successfully generated in the standard model with higher-dimensional operators.

  13. Comparative Evaluation of Vacuum-based Surface Sampling ...

    EPA Pesticide Factsheets

    Journal Article Following a biological contamination incident, collection of surface samples is necessary to determine the extent and level of contamination, and to deem an area safe for reentry upon decontamination. Current sampling strategies targeting Bacillus anthracis spores prescribe vacuum-based methods for rough and/or porous surfaces. In this study, four commonly-used B. anthracis spore sampling devices (vacuum socks, 37 mm 0.8 µm MCE filter cassettes, 37 mm 0.3 µm PTFE filter cassettes, and 3MTM forensic filters) were comparatively evaluated for their ability to recover surface-associated spores. The vacuum sock device was evaluated at two sampling speeds (slow and fast), resulting in five total methods evaluated. Aerosolized spores (~105 cm-2) of a surrogate Bacillus species (Bacillus atrophaeus) were allowed to settle onto three material types (concrete, carpet, and upholstery). Ten replicate samples were collected using each vacuum method, from each of the three material types. In addition, stainless steel (i.e., nonporous) surfaces inoculated simultaneously were sampled with pre-moistened wipes. Recoveries from wipes of steel surfaces were utilized to verify the inoculum, and to normalize vacuum-based recoveries across trials. Recovery (CFU cm-2) and relative recovery (vacuum recovery/wipe recovery) were determined for each method and material type. Relative recoveries were compared by one-way and three-way ANOVA. Data analysis by one-

  14. Vacuum energy from noncommutative models

    NASA Astrophysics Data System (ADS)

    Mignemi, S.; Samsarov, A.

    2018-04-01

    The vacuum energy is computed for a scalar field in a noncommutative background in several models of noncommutative geometry. One may expect that the noncommutativity introduces a natural cutoff on the ultraviolet divergences of field theory. Our calculations show however that this depends on the particular model considered: in some cases the divergences are suppressed and the vacuum energy is only logarithmically divergent, in other cases they are stronger than in the commutative theory.

  15. Sealed vacuum canister and method for pick-up and containment of material

    DOEpatents

    Stoutenburgh, Roger R.

    1996-01-01

    A vacuum canister including a housing with a sealed vacuum chamber having a predetermined vacuum pressure therein and a valve having a first port for fluid communication with the vacuum chamber and a second port for receiving at least one of a fluid and a particulate material. The valve is operable between a first position to seal the vacuum chamber and retain the predetermined vacuum within the vacuum chamber, and a second position to access the vacuum chamber to permit vacuum fluid flow through the valve from the second port into the vacuum chamber. In operation of the vacuum canister to pick up material with the valve in the second position, when the second port is located adjacent at least one of a fluid and a particulate material, is effective to displace through the valve at least one of a fluid and a particulate material into the housing. The vacuum canister is desirably suitable for picking up and containing hazardous material such as radioactive material, in which the vacuum canister includes a protective layer of lead having a predetermined thickness that is effective to shield radiation emitted from the radioactive material contained within the housing. Advantageously, the vacuum canister includes a vacuum means for establishing a predetermined vacuum pressure within the vacuum chamber.

  16. Fast Interrupt Priority Management in Operating System Kernels

    DTIC Science & Technology

    1993-05-01

    We present results for the Mach 3.0 microkernel operating system, although the technique is applicable to other kernel architectures, both micro and...protection in the Mach 3.0 microkernel for several different processor architectures. For example, on the Omron Luna88k, we observed a 50% reduction in...general interrupt mask raise/lower pair within the Mach 3.0 microkernel on a variety of architectures. DTIC QUALM i.N1’R%.*1IMD 5 k81tltC Avail andl

  17. An ultra-high vacuum chamber for scattering experiments featuring in-vacuum continuous in-plane variation of the angle between entrance and exit vacuum ports

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Englund, Carl-Johan; Agåker, Marcus, E-mail: marcus.agaker@physics.uu.se; Fredriksson, Pierre

    2015-09-15

    A concept that enables in-vacuum continuous variation of the angle between two ports in one plane has been developed and implemented. The vacuum chamber allows for measuring scattering cross sections as a function of scattering angle and is intended for resonant inelastic X-ray scattering experiments. The angle between the ports can be varied in the range of 30°-150°, while the pressure change is less than 2 × 10{sup −10} mbars.

  18. Cognitive load selectively influences the interruptive effect of pain on attention.

    PubMed

    Moore, David J; Eccleston, Christopher; Keogh, Edmund

    2017-10-01

    Pain is known to interrupt attentional performance. Such interference effects seem to occur preferentially for tasks that are complex and/or difficult. However, few studies have directly manipulated memory load in the context of pain interference to test this view. Therefore, this study examines the effect of experimental manipulations of both memory load and pain on 3 tasks previously found to be sensitive to pain interference. Three experiments were conducted. A different task was examined in each experiment, each comprising of a high- and low-cognitive load versions of the task. Experiment 1 comprised an attention span (n-back) task, experiment 2 an attention switching task, and experiment 3 a divided attention task. Each task was conducted under painful and nonpainful conditions. Within the pain condition, an experimental thermal pain induction protocol was administered at the same time participants completed the task. The load manipulations were successful in all experiments. Pain-related interference occurred under the high-load condition but only for the attention span task. No effect of pain was found on either the attentional switching or divided attention task. These results suggest that while cognitive load may influence the interruptive effect of pain on attention, this effect may be selective. Because pain affected the high-load version of the n-back task but did not interrupt performance on attentional switching or dual-task paradigms, this means that our findings did not completely support our hypotheses. Future research should explore further the parameters and conditions under which pain-related interference occurs.

  19. Overview of Fabrication Techniques and Lessons Learned with Accelerator Vacuum Windows

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ader, C. R.; McGee, M. W.; Nobrega, L. E.

    Vacuum thin windows have been used in Fermilab's accelerators for decades and typically have been overlooked in terms of their criticality and fragility. Vacuum windows allow beam to pass through while creating a boundary between vacuum and air or high vacuum and low vacuum areas. The design of vacuum windows, including Titanium and Beryllium windows, will be discussed as well as fabrication, testing, and operational concerns. Failure of windows will be reviewed as well as safety approaches to mitigating failures and extending the lifetimes of vacuum windows. Various methods of calculating the strengths of vacuum windows will be explored, includingmore » FEA.« less

  20. Safety shield for vacuum/pressure-chamber windows

    NASA Technical Reports Server (NTRS)

    Shimansky, R. A.; Spencer, R.

    1980-01-01

    Optically-clear shatter-resistant safety shield protects workers from implosion and explosion of vacuum and pressure windows. Plastic shield is inexpensive and may be added to vacuum chambers, pressure chambers, and gas-filling systems.

  1. Vacuum tool manipulator

    DOEpatents

    Zollinger, W.T.

    1993-11-23

    Apparatus for manipulating a vacuum hose in a reactor vessel comprises a housing with two opposing openings, an arm carried by the housing and deployable from a stowed position essentially completely within the housing to an extended position where the arm extends through the two openings in a generally horizontal position. The arm preferably has a two-fingered gripping device for gripping the vacuum hose but may carry a different end effector such as a grinding wheel. The fingers are opened and closed by one air cylinder. A second air cylinder extends the device. A third air cylinder within the housing pivotally pulls the opposing end of the arm into the housing via a pivoting member pivotally connected between the third air cylinder shaft and the arm. 6 figures.

  2. Entangled de Sitter from stringy axionic Bell pair I: an analysis using Bunch-Davies vacuum

    NASA Astrophysics Data System (ADS)

    Choudhury, Sayantan; Panda, Sudhakar

    2018-01-01

    In this work, we study the quantum entanglement and compute entanglement entropy in de Sitter space for a bipartite quantum field theory driven by an axion originating from Type IIB string compactification on a Calabi-Yau three fold (CY^3) and in the presence of an NS5 brane. For this computation, we consider a spherical surface S^2, which divides the spatial slice of de Sitter (dS_4) into exterior and interior sub-regions. We also consider the initial choice of vacuum to be Bunch-Davies state. First we derive the solution of the wave function of the axion in a hyperbolic open chart by constructing a suitable basis for Bunch-Davies vacuum state using Bogoliubov transformation. We then derive the expression for density matrix by tracing over the exterior region. This allows us to compute the entanglement entropy and Rényi entropy in 3+1 dimension. Furthermore, we quantify the UV-finite contribution of the entanglement entropy which contain the physics of long range quantum correlations of our expanding universe. Finally, our analysis complements the necessary condition for generating non-vanishing entanglement entropy in primordial cosmology due to the axion.

  3. Extreme-UV lithography vacuum chamber zone seal

    DOEpatents

    Haney, Steven J.; Herron, Donald Joe; Klebanoff, Leonard E.; Replogle, William C.

    2001-01-01

    Control of particle contamination on the reticle and carbon contamination of optical surfaces in photolithography systems can be achieved by the establishment of multiple pressure zones in the photolithography systems. The different zones will enclose the reticle, projection optics, wafer, and other components of system. The system includes a vacuum apparatus that includes: a housing defining a vacuum chamber; one or more metrology trays situated within the vacuum chamber each of which is supported by at least one support member, wherein the tray separates the vacuum chamber into a various compartments that are maintained at different pressures; and conductance seal devices for adjoining the perimeter of each tray to an inner surface of the housing wherein the tray is decoupled from vibrations emanating from the inner surface of the housing.

  4. Extreme-UV lithography vacuum chamber zone seal

    DOEpatents

    Haney, Steven J.; Herron, Donald Joe; Klebanoff, Leonard E.; Replogle, William C.

    2003-04-08

    Control of particle contamination on the reticle and carbon contamination of optical surfaces in photolithography systems can be achieved by the establishment of multiple pressure zones in the photolithography systems. The different zones will enclose the reticle, projection optics, wafer, and other components of system. The system includes a vacuum apparatus that includes: a housing defining a vacuum chamber; one or more metrology trays situated within the vacuum chamber each of which is supported by at least one support member, wherein the tray separates the vacuum chamber into a various compartments that are maintained at different pressures; and conductance seal devices for adjoining the perimeter of each tray to an inner surface of the housing wherein the tray is decoupled from vibrations emanating from the inner surface of the housing.

  5. Extreme-UV lithography vacuum chamber zone seal

    DOEpatents

    Haney, Steven J.; Herron, Donald Joe; Klebanoff, Leonard E.; Replogle, William C.

    2003-04-15

    Control of particle contamination on the reticle and carbon contamination of optical surfaces in photolithography systems can be achieved by the establishment of multiple pressure zones in the photolithography systems. The different zones will enclose the reticle, projection optics, wafer, and other components of system. The system includes a vacuum apparatus that includes: a housing defining a vacuum chamber; one or more metrology trays situated within the vacuum chamber each of which is supported by at least one support member, wherein the tray separates the vacuum chamber into a various compartments that are maintained at different pressures; and conductance seal devices for adjoining the perimeter of each tray to an inner surface of the housing wherein the tray is decoupled from vibrations emanating from the inner surface of the housing.

  6. Vacuum deposition and curing of liquid monomers apparatus

    DOEpatents

    Affinito, J.D.

    1996-08-20

    The present invention is the formation of solid polymer layers under vacuum. More specifically, the present invention is the use of ``standard`` polymer layer-making equipment that is generally used in an atmospheric environment in a vacuum, and degassing the monomer material prior to injection into the vacuum. Additional layers of polymer or metal or oxide may be vacuum deposited onto solid polymer layers. Formation of polymer layers under a vacuum improves material and surface characteristics, and subsequent quality of bonding to additional layers. Further advantages include use of less to no photoinitiator for curing, faster curing, fewer impurities in the polymer electrolyte, as well as improvement in material properties including no trapped gas resulting in greater density, and reduced monomer wetting angle that facilitates spreading of the monomer and provides a smoother finished surface. 3 figs.

  7. Interruptions and multitasking in surgery: a multicentre observational study of the daily work patterns of doctors and nurses.

    PubMed

    Bellandi, Tommaso; Cerri, Alessandro; Carreras, Giulia; Walter, Scott; Mengozzi, Cipriana; Albolino, Sara; Mastrominico, Eleonora; Renzetti, Fernando; Tartaglia, Riccardo; Westbrook, Johanna

    2018-01-01

    The aim of this study was to obtain baseline data on doctors' and nurses' work activities and rates of interruptions and multitasking to improve work organisation and processes. Data were collected in six surgical units with the WOMBAT (Work Observation Method by Activity Timing) tool. Results show that doctors and nurses received approximately 13 interruptions per hour, or one interruption every 4.5 min. Compared to doctors, nurses were more prone to interruptions in most activities, while doctors performed multitasking (33.47% of their time, 95% CI 31.84-35.17%) more than nurses (15.23%, 95% CI 14.24-16.25%). Overall, the time dedicated to patient care is relatively limited for both professions (37.21%, 95% CI 34.95-39.60% for doctors, 27.22%, 95% CI 25.18-29.60% for nurses) compared to the time spent for registration of data and professional communication, that accounts for two-thirds of doctors' time and nearly half of nurses' time. Further investigation is needed on strategies to manage job demands and professional communications. Practitioner Summary: This study offers further findings on the characteristics and frequency of multitasking and interruptions in surgery, with a comparison of how they affect doctors and nurses. Further investigation is needed to improve the management of job demands and communications according to the results.

  8. Microbial analysis of meatballs cooled with vacuum and conventional cooling.

    PubMed

    Ozturk, Hande Mutlu; Ozturk, Harun Kemal; Koçar, Gunnur

    2017-08-01

    Vacuum cooling is a rapid evaporative cooling technique and can be used for pre-cooling of leafy vegetables, mushroom, bakery, fishery, sauces, cooked food, meat and particulate foods. The aim of this study was to apply the vacuum cooling and the conventional cooling techniques for the cooling of the meatball and to show the vacuum pressure effect on the cooling time, the temperature decrease and microbial growth rate. The results of the vacuum cooling and the conventional cooling (cooling in the refrigerator) were compared with each other for different temperatures. The study shows that the conventional cooling was much slower than the vacuum cooling. Moreover, the microbial growth rate of the vacuum cooling was extremely low compared with the conventional cooling. Thus, the lowest microbial growth occurred at 0.7 kPa and the highest microbial growth was observed at 1.5 kPa for the vacuum cooling. The mass loss ratio for the conventional cooling and vacuum cooling was about 5 and 9% respectively.

  9. Recycling of waste lead storage battery by vacuum methods.

    PubMed

    Lin, Deqiang; Qiu, Keqiang

    2011-07-01

    Waste lead storage battery is the most important recyclable lead material not only in various European and other OECD countries but also in China. Pollution control of lead has become the focus of people's attention in the world. A vacuum process for recycling waste lead storage battery was developed in this work. The experimental results showed that all the valuable materials in waste lead storage battery could be satisfactorily recycled by vacuum technologies. The vacuum melting of lead grids and the vacuum reduction of lead pastes produce the lead bullion with the direct recovery ratio of 96.29% and 98.98%, respectively. The vacuum pyrolysis of plastics can produce pyrolysis oil with yield of more than 93 wt.%. These vacuum recycling technologies offer improvements in metallurgical and environmental performance. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Window-assisted nanosphere lithography for vacuum micro-nano-electronics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Nannan; Institute of Electronic Engineering, Chinese Academy of Engineering Physics, Mianyang, 621900; Pang, Shucai

    2015-04-15

    Development of vacuum micro-nano-electronics is quite important for combining the advantages of vacuum tubes and solid-state devices but limited by the prevailing fabricating techniques which are expensive, time consuming and low-throughput. In this work, window-assisted nanosphere lithography (NSL) technique was proposed and enabled the low-cost and high-efficiency fabrication of nanostructures for vacuum micro-nano-electronic devices, thus allowing potential applications in many areas. As a demonstration, we fabricated high-density field emitter arrays which can be used as cold cathodes in vacuum micro-nano-electronic devices by using the window-assisted NSL technique. The details of the fabricating process have been investigated. This work provided amore » new and feasible idea for fabricating nanostructure arrays for vacuum micro-nano-electronic devices, which would spawn the development of vacuum micro-nano-electronics.« less

  11. Sealed vacuum canister and method for pick-up and containment of material

    DOEpatents

    Stoutenburgh, R.R.

    1996-02-13

    A vacuum canister is described including a housing with a sealed vacuum chamber having a predetermined vacuum pressure therein and a valve having a first port for fluid communication with the vacuum chamber and a second port for receiving at least one of a fluid and a particulate material. The valve is operable between a first position to seal the vacuum chamber and retain the predetermined vacuum within the vacuum chamber, and a second position to access the vacuum chamber to permit vacuum fluid flow through the valve from the second port into the vacuum chamber. The vacuum canister, in the operation to pick up material with the valve in the second position, when the second port is located adjacent at least one of a fluid and a particulate material, is effective to displace through the valve at least one of a fluid and a particulate material into the housing. The vacuum canister is desirably suitable for picking up and containing hazardous material such as radioactive material, in which the vacuum canister includes a protective layer of lead having a predetermined thickness that is effective to shield radiation emitted from the radioactive material contained within the housing. Advantageously, the vacuum canister includes a vacuum means for establishing a predetermined vacuum pressure within the vacuum chamber. 6 figs.

  12. Building and Verifying a Predictive Model of Interruption Resumption

    DTIC Science & Technology

    2012-03-01

    field, the vocal module speaks, the motor module moves the body, and the con- figural and manipulative modules perform spatial proces- sing [14]–[16...person cannot remember themselves. As described earlier, the model depends critically upon the basic properties of declarative memories. When a...success because the model’s ability to re- trieve an episodic code depends critically on the amount of time spent on the interruption. Also recall that

  13. Vacuum transfer system increases sugar maple sap yield

    Treesearch

    Russell S. Walters

    1978-01-01

    Yields of sugar maple sap collected from three plastic pipeline systems by gravity, vacuum pump, and a vacuum pump with a transfer tank were compared during 2 years in northern Vermont. The transfer system yielded 27 percent more sap one year and 17 percent more the next year. Higher vacuum levels at the tapholes were observed in the transfer system.

  14. Vacuum plasma coatings for turbine blades

    NASA Technical Reports Server (NTRS)

    Holmes, R. R.

    1985-01-01

    Turbine blades, vacuum plasma spray coated with NiCrAlY, CoCrAlY or NiCrAlY/Cr2O3, were evaluated and rated superior to standard space shuttle main engine (SSME) coated blades. Ratings were based primarily on 25 thermal cycles in the MSFC Burner Rig Tester, cycling between 1700 F (gaseous H2) and -423 F (liquid H2). These tests showed no spalling on blades with improved vacuum plasma coatings, while standard blades spalled. Thermal barrier coatings of ZrO2, while superior to standard coatings, lacked the overall performance desired. Fatigue and tensile specimens, machined from MAR-M-246(Hf) test bars identical to the blades were vacuum plasma spray coated, diffusion bond treated, and tested to qualify the vacuum plasma spray process for flight hardware testing and application. While NiCrAlY/Cr2O3 offers significant improvement over standard coatings in durability and thermal protection, studies continue with an objective to develop coatings offering even greater improvements.

  15. Self contained, independent, in-vacuum spinner motor

    DOEpatents

    Ayers, Marion J.

    2002-01-01

    An independent, self contained apparatus for operation within a vacuum chamber. A sealed enclosure is located in the chamber. The enclosure contains its own atmosphere independent of the vacuum in the chamber. A motor, power unit, and controls are located entirely within the enclosure. They do not have a direct structural connection outside of the enclosure in any way that would effect the atmosphere within the enclosure. The motor, power unit, and controls drive a spinner plate located outside the enclosure but within the vacuum chamber.

  16. Structured intermittent interruption of chronic HIV infection treatment with highly active antiretroviral therapy: effects on leptin and TNF-alpha.

    PubMed

    Arjona, M Montes de Oca; Pérez-Cano, R; Garcia-Juárez, R; Martín-Aspas, A; del Alamo, C Fernández Gutiérrez; Girón-González, J A

    2006-04-01

    The changes in nutritional parameters and adipocytokines after structured intermittent interruption of highly active antiretroviral treatment of patients with chronic HIV infection are analyzed. Twenty-seven patients with chronic HIV infection (median CD4+ T cell count/microl: nadir, 394; at the beginning of structured interruptions, 1041; HIV viral load: nadir, 41,521 copies/ml; at the beginning of structured interruptions <50 copies/ml; median time of previous treatment: 60 months) were evaluated during three cycles of intermittent interruptions of therapy (8 weeks on/4 weeks off). CD4+ T cell count, HIV viral load, anthropometric measures, and serum concentrations of triglycerides, cholesterol, leptin, and tumor necrosis factor and its soluble receptors I and II were determined. After the three cycles of intermittent interruptions of therapy, no significant differences in CD4+ T cell count/microl, viral load, or serum concentrations of cholesterol or triglycerides with reference to baseline values were found. A near-significant higher fatty mass (skinfold thicknesses, at the end, 121 mm, at the beginning, 100 mm, p = 0.100), combined with a significant increase of concentration of leptin (1.5 vs. 4.7 ng/ml, p = 0,044), as well as a decrease in serum concentrations of soluble receptors of tumor necrosis factor (TNFRI, 104 vs. 73 pg/ml, p = 0.022; TNFRII 253 vs. 195 pg/ml, p = 0.098) were detected. Structured intermittent interruption of highly active antiretroviral treatment of patients with chronic HIV infection induces a valuable positive modification in markers of lipid turnover and adipose tissue mass.

  17. Children's Avoidance of Interrupting Others' Activities in Requesting Help: Cultural Aspects of Considerateness.

    PubMed

    Ruvalcaba, Omar; Rogoff, Barbara; López, Angélica; Correa-Chávez, Maricela; Gutiérrez, Kris

    2015-01-01

    To be able to collaborate skillfully, people need to coordinate well with others, taking into account how their actions fit with those of their partners. This is a key aspect of an approach to learning called Learning by Observing and Pitching In, hypothesized to be common in many Indigenous-heritage communities of the Americas. This chapter considers cultural values that emphasize considerateness and awareness of how one's actions impact others such as the Mexican cultural value of respeto and cultural differences in children's efforts to avoid interrupting others' activity. US Mexican-heritage children showed more evidence of avoiding interrupting the ongoing activity of an adult when they requested help, compared with European American children from families with extensive schooling experience. Most of the Mexican-heritage children's requests for help that gave evidence of avoiding interruption were made nonverbally, which may facilitate unobtrusive requests. There were no significant differences among children from two US Mexican-heritage backgrounds varying in experience with Western schooling and likely experience with Indigenous-American practices, suggesting that the Mexican cultural value of respeto and associated considerateness is widespread even among US Mexican-heritage families with extensive experience with Western schooling and life in the United States. © 2015 Elsevier Inc. All rights reserved.

  18. Microscale Digital Vacuum Electronic Gates

    NASA Technical Reports Server (NTRS)

    Manohara, Harish (Inventor); Mojarradi, Mohammed M. (Inventor)

    2014-01-01

    Systems and methods in accordance with embodiments of the invention implement microscale digital vacuum electronic gates. In one embodiment, a microscale digital vacuum electronic gate includes: a microscale field emitter that can emit electrons and that is a microscale cathode; and a microscale anode; where the microscale field emitter and the microscale anode are disposed within at least a partial vacuum; where the microscale field emitter and the microscale anode are separated by a gap; and where the potential difference between the microscale field emitter and the microscale anode is controllable such that the flow of electrons between the microscale field emitter and the microscale anode is thereby controllable; where when the microscale anode receives a flow of electrons, a first logic state is defined; and where when the microscale anode does not receive a flow of electrons, a second logic state is defined.

  19. Instrument for measurement of vacuum in sealed thin wall packets

    DOEpatents

    Kollie, T.G.; Thacker, L.H.; Fine, H.A.

    1995-04-18

    An instrument is disclosed for the measurement of vacuum within sealed packets, the packets having a wall that it can be deformed by the application of an external dynamic vacuum to an area thereof. The instrument has a detector head for placement against the deformable wall of the packet to apply the vacuum in a controlled manner to accomplish a limited deformation or lift of the wall with this deformation or lift monitored by the application of light as via a bifurcated light pipe. Retro-reflected light through the light pipe is monitored with a photo detector. A change (e.g., a decrease) of retro-reflected light signals the wall movement such that the value of the dynamic vacuum applied through the head be to achieve this initiation of movement is equal to the vacuum within the packet. In a preferred embodiment a vacuum plate is placed beneath the packet to ensure that no deformation occurs on the reverse surface of the packet. A vacuum can be applied to a recess in this vacuum plate, the value of which can be used to calibrate the vacuum transducer in the detector head. 4 figs.

  20. Influence of residual plasma drift velocity on the post-arc sheath expansion of vacuum circuit breakers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mo, Yongpeng; Shi, Zongqian; Jia, Shenli

    The residual plasma in the inter-contact region of a vacuum circuit breaker moves towards the post-arc cathode at current zero, because the residual plasma mainly comes from the cathode spots during the arc burning process. In the most previous theoretical researches on the post-arc sheath expansion process of vacuum circuit breakers, only the thermal motion of residual plasma was taken into consideration. Alternately, the residual plasma was even assumed to be static at the moment of current zero in some simplified models. However, the influence of residual plasma drift velocity at current zero on the post-arc sheath expansion process wasmore » rarely investigated. In this paper, this effect is investigated by a one-dimensional particle-in-cell model. Simulation results indicate that the sheath expands slower with higher residual plasma drift velocity in the initial sheath expansion stage. However, with the increase of residual plasma drift velocity, the overall plasma density in the inter-contact region decreases faster, and the sheath expansion velocity increases earlier. Consequently, as a whole, it needs shorter time to expel the residual plasma from the inter-contact region. Furthermore, if the residual plasma drift velocity is high enough, the sheath expansion process ceases before it develops to the post-arc anode. Besides, the influence of the collisions between charges and neutrals is investigated as well in terms of the density of metal vapor. It shows that the residual plasma drift velocity takes remarkable effect only if the density of the metal vapor is relatively low, which corresponds to the circumstance of low-current interruptions.« less

  1. Dyonic Flux Tube Structure of Nonperturbative QCD Vacuum

    NASA Astrophysics Data System (ADS)

    Chandola, H. C.; Pandey, H. C.

    We study the flux tube structure of the nonperturbative QCD vacuum in terms of its dyonic excitations by using an infrared effective Lagrangian and show that the dyonic condensation of QCD vacuum has a close connection with the process of color confinement. Using the fiber bundle formulation of QCD, the magnetic symmetry condition is presented in a gauge covariant form and the gauge potential has been constructed in terms of the magnetic vectors on global sections. The dynamical breaking of the magnetic symmetry has been shown to lead the dyonic condensation of QCD vacuum in the infrared energy sector. Deriving the asymptotic solutions of the field equations in the dynamically broken phase, the dyonic flux tube structure of QCD vacuum is explored which has been shown to lead the confinement parameters in terms of the vector and scalar mass modes of the condensed vacuum. Evaluating the charge quantum numbers and energy associated with the dyonic flux tube solutions, the effect of electric excitation of monopole is analyzed using the Regge slope parameter (as an input parameter) and an enhancement in the dyonic pair correlations and the confining properties of QCD vacuum in its dyonically condensed mode has been demonstrated.

  2. Flow Visualization Proposed for Vacuum Cleaner Nozzle Designs

    NASA Technical Reports Server (NTRS)

    2005-01-01

    In 1995, the NASA Lewis Research Center and the Kirby Company (a major vacuum cleaner company) began negotiations for a Space Act Agreement to conduct research, technology development, and testing involving the flow behavior of airborne particulate flow behavior. Through these research efforts, we hope to identify ways to improve suction, flow rate, and surface agitation characteristics of nozzles used in vacuum cleaner nozzles. We plan to apply an advanced visualization technology, known as Stereoscopic Imaging Velocimetry (SIV), to a Kirby G-4 vacuum cleaner. Resultant data will be analyzed with a high-speed digital motion analysis system. We also plan to evaluate alternative vacuum cleaner nozzle designs. The overall goal of this project is to quantify both velocity fields and particle trajectories throughout the vacuum cleaner nozzle to optimize its "cleanability"--its ability to disturb and remove embedded dirt and other particulates from carpeting or hard surfaces. Reference

  3. Red rubber bulb, cheap and effective vacuum drainage.

    PubMed

    Vatanasapt, V; Areemit, S; Jeeravipoolvarn, P; Kuyyakanond, T; Kuptarnond, C

    1989-04-01

    Red rubber bulbs have been used for vacuum drainage in head, neck, breast and several other operations by the authors since 1975 quite effectively without any major problems. The vacuum pressure of the red rubber bulbs was found to be higher than the expensive commercially available vacuum wound drainage device. The question of remaining old blood and infective microorganisms inside the reservoir for the reused ones were tested by the manual cleaning process and the standard sterile technique using steam under increased pressure (autoclave). The result is quite satisfactory. We encourage the use of this cheap and effective (made in Thailand) vacuum wound drainage in Thai hospitals and Thai medical schools.

  4. Study of Vacuum Energy Physics for Breakthrough Propulsion

    NASA Technical Reports Server (NTRS)

    Millis, Marc G. (Technical Monitor); Maclay, G. Jordan; Hammer, Jay; Clark, Rod; George, Michael; Kim, Yeong; Kir, Asit

    2004-01-01

    This report summarizes the accomplishments during a three year research project to investigate the use of surfaces, particularly in microelectromechanical systems (MEMS), to exploit quantum vacuum forces. During this project, we developed AFM instrumentation to repeatably measure Casimir forces in the nanoNewton range at 10 6 torr, designed an experiment to measure attractive and repulsive quantum vacuum forces, developed a QED based theory of Casimir forces that includes non-ideal material properties for rectangular cavities and for multilayer slabs, developed theoretical models for a variety of microdevices utilizing vacuum forces, applied vacuum physics to a gedanken spacecraft, and investigated a new material with a negative index of refraction.

  5. Fast MRI-guided vacuum-assisted breast biopsy: initial experience.

    PubMed

    Liberman, Laura; Morris, Elizabeth A; Dershaw, D David; Thornton, Cynthia M; Van Zee, Kimberly J; Tan, Lee K

    2003-11-01

    The purpose of this study was to evaluate a new method for performing MRI-guided vacuum-assisted breast biopsy in a study of lesions that had subsequent surgical excision. SUBJECTS AND METHODS. Twenty women scheduled for MRI-guided needle localization and surgical biopsy were prospectively entered in the study. MRI-guided biopsy was performed with a vacuum-assisted probe, followed by placement of a localizing clip, and then needle localization for surgical excision. Vacuum-assisted biopsy and surgical histology were correlated. Vacuum-assisted biopsy was successfully performed in 19 (95%) of the 20 women. The median size of 27 MRI-detected lesions that had biopsy was 1.0 cm (range, 0.4-6.4 cm). Cancer was present in eight (30%) of 27 lesions and in six (32%) of 19 women; among these eight cancers, five were infiltrating and three were ductal carcinoma in situ (DCIS). Among these 27 lesions, histology was benign at vacuum-assisted biopsy and at surgery in 19 (70%), cancer at vacuum-assisted biopsy in six (22%), atypical ductal hyperplasia at vacuum-assisted biopsy and DCIS at surgery in one (4%), and benign at vacuum-assisted biopsy with surgery showing microscopic DCIS that was occult at MRI in one (4%). The median time to perform vacuum-assisted biopsy of a single lesion was 35 min (mean, 35 min; range, 24-48 min). Placement of a localizing clip, attempted in 26 lesions, was successful in 25 (96%) of 26, and the clip was retrieved on specimen radiography in 22 (96%) of 23. One complication occurred: a hematoma that resolved with compression. MRI-guided vacuum-assisted biopsy is a fast, safe, and accurate alternative to surgical biopsy for breast lesions detected on MRI.

  6. Measuring the relationship between interruptions, multitasking and prescribing errors in an emergency department: a study protocol

    PubMed Central

    Raban, Magdalena Z; Walter, Scott R; Douglas, Heather E; Strumpman, Dana; Mackenzie, John; Westbrook, Johanna I

    2015-01-01

    Introduction Interruptions and multitasking are frequent in clinical settings, and have been shown in the cognitive psychology literature to affect performance, increasing the risk of error. However, comparatively less is known about their impact on errors in clinical work. This study will assess the relationship between prescribing errors, interruptions and multitasking in an emergency department (ED) using direct observations and chart review. Methods and analysis The study will be conducted in an ED of a 440-bed teaching hospital in Sydney, Australia. Doctors will be shadowed at proximity by observers for 2 h time intervals while they are working on day shift (between 0800 and 1800). Time stamped data on tasks, interruptions and multitasking will be recorded on a handheld computer using the validated Work Observation Method by Activity Timing (WOMBAT) tool. The prompts leading to interruptions and multitasking will also be recorded. When doctors prescribe medication, type of chart and chart sections written on, along with the patient's medical record number (MRN) will be recorded. A clinical pharmacist will access patient records and assess the medication orders for prescribing errors. The prescribing error rate will be calculated per prescribing task and is defined as the number of errors divided by the number of medication orders written during the prescribing task. The association between prescribing error rates, and rates of prompts, interruptions and multitasking will be assessed using statistical modelling. Ethics and dissemination Ethics approval has been obtained from the hospital research ethics committee. Eligible doctors will be provided with written information sheets and written consent will be obtained if they agree to participate. Doctor details and MRNs will be kept separate from the data on prescribing errors, and will not appear in the final data set for analysis. Study results will be disseminated in publications and feedback to the ED. PMID

  7. Feed-through connector couples RF power into vacuum chamber

    NASA Technical Reports Server (NTRS)

    Grandy, G. L.

    1967-01-01

    Feed-through device connects RF power to an RF coil in a vacuum chamber. The coil and leads are water cooled and vacuum tight seals are provided at the junctions. The device incorporates silver soldered copper tubes, polytetrafluoroethylene electrical insulators, and O-ring vacuum seals.

  8. Alert dwell time: introduction of a measure to evaluate interruptive clinical decision support alerts.

    PubMed

    McDaniel, Robert B; Burlison, Jonathan D; Baker, Donald K; Hasan, Murad; Robertson, Jennifer; Hartford, Christine; Howard, Scott C; Sablauer, Andras; Hoffman, James M

    2016-04-01

    Metrics for evaluating interruptive prescribing alerts have many limitations. Additional methods are needed to identify opportunities to improve alerting systems and prevent alert fatigue. In this study, the authors determined whether alert dwell time-the time elapsed from when an interruptive alert is generated to when it is dismissed-could be calculated by using historical alert data from log files. Drug-drug interaction (DDI) alerts from 3 years of electronic health record data were queried. Alert dwell time was calculated for 25,965 alerts, including 777 unique DDIs. The median alert dwell time was 8 s (range, 1-4913 s). Resident physicians had longer median alert dwell times than other prescribers (P < 001). The 10 most frequent DDI alerts (n = 8759 alerts) had shorter median dwell times than alerts that only occurred once (P < 001). This metric can be used in future research to evaluate the effectiveness and efficiency of interruptive prescribing alerts. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. Heat transfer in a liquid helium cooled vacuum tube following sudden vacuum loss

    NASA Astrophysics Data System (ADS)

    Dhuley, R. C.; Van Sciver, S. W.

    2015-12-01

    Condensation of nitrogen gas rapidly flowing into a liquid helium (LHe) cooled vacuum tube is studied. This study aims to examine the heat transfer in geometries such as the superconducting RF cavity string of a particle accelerator following a sudden loss of vacuum to atmosphere. In a simplified experiment, the flow is generated by quickly venting a large reservoir of nitrogen gas to a straight long vacuum tube immersed in LHe. Normal LHe (LHe I) and superfluid He II are used in separate experiments. The rate of condensation heat transfer is determined from the temperature of the tube measured at several locations along the gas flow. Instantaneous heat deposition rates in excess of 200 kW/m2 result from condensation of the flowing gas. The gas flow is then arrested in its path to pressurize the tube to atmosphere and estimate the heat transfer rate to LHe. A steady LHe I heat load of ≈25 kW/m2 is obtained in this scenario. Observations from the He II experiment are briefly discussed. An upper bound for the LHe I heat load is derived based on the thermodynamics of phase change of nitrogen.

  10. The trophic vacuum and the evolution of complex life cycles in trophically transmitted helminths.

    PubMed

    Benesh, Daniel P; Chubb, James C; Parker, Geoff A

    2014-10-22

    Parasitic worms (helminths) frequently have complex life cycles in which they are transmitted trophically between two or more successive hosts. Sexual reproduction often takes place in high trophic-level (TL) vertebrates, where parasites can grow to large sizes with high fecundity. Direct infection of high TL hosts, while advantageous, may be unachievable for parasites constrained to transmit trophically, because helminth propagules are unlikely to be ingested by large predators. Lack of niche overlap between propagule and definitive host (the trophic transmission vacuum) may explain the origin and/or maintenance of intermediate hosts, which overcome this transmission barrier. We show that nematodes infecting high TL definitive hosts tend to have more successive hosts in their life cycles. This relationship was modest, though, driven mainly by the minimum TL of hosts, suggesting that the shortest trophic chains leading to a host define the boundaries of the transmission vacuum. We also show that alternative modes of transmission, like host penetration, allow nematodes to reach high TLs without intermediate hosts. We suggest that widespread omnivory as well as parasite adaptations to increase transmission probably reduce, but do not eliminate, the barriers to the transmission of helminths through the food web. © 2014 The Author(s) Published by the Royal Society. All rights reserved.

  11. 33 CFR 159.89 - Power interruption: Type I and II devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Power interruption: Type I and II devices. 159.89 Section 159.89 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) POLLUTION MARINE SANITATION DEVICES Design, Construction, and Testing § 159.89 Power...

  12. Multipath Very-Simplified Estimate of Adversary Sequence Interruption v. 2.1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Snell, Mark K.

    2017-10-10

    MP VEASI is a training tool that models physical protection systems for fixed sites using Adversary Sequence Diagrams (ASDs) and then uses the ASD to find most-vulnerable adversary paths through the ASD. The identified paths have the lowest Probability of Interruption among all the paths through the ASD.

  13. Pardon the Interruption: Enhancing Communication Skills for Students with Intellectual Disability

    ERIC Educational Resources Information Center

    Bayes, Daniel A.; Heath, Amy K.; Williams, Carol; Ganz, Jennifer B.

    2013-01-01

    This article provides teachers and parents with a description of the behavior chain interruption strategy (BCIS), an evidence-based intervention for increasing requesting behaviors in individuals with moderate to severe disabilities. A review of the relevant literature is provided, as well as a description of the behavioral principles that…

  14. Instrument for measurement of vacuum in sealed thin wall packets

    DOEpatents

    Kollie, Thomas G.; Thacker, Louis H.; Fine, H. Alan

    1995-01-01

    An instrument for the measurement of vacuum within sealed packets 12, the packets 12 having a wall 14 that it can be deformed by the application of an external dynamic vacuum to an area thereof. The instrument has a detector head 18 for placement against the deformable wall 14 of the packet to apply the vacuum in a controlled manner to accomplish a limited deformation or lift of the wall 14, with this deformation or lift monitored by the application of light as via a bifurcated light pipe 20. Retro-reflected light through the light pipe is monitored with a photo detector 26. A change (e.g., a decrease) of retro-reflected light signals the wall movement such that the value of the dynamic vacuum applied through the head be to achieve this initiation of movement is equal to the vacuum within the packet 12. In a preferred embodiment a vacuum plate 44 is placed beneath the packet 12 to ensure that no deformation occurs on the reverse surface 16 of the packet. A vacuum can be applied to a recess in this vacuum plate, the value of which can be used to calibrate the vacuum transducer in the detector head.

  15. 7 CFR 58.217 - Evaporators and/or vacuum pans.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ....217 Evaporators and/or vacuum pans. Evaporators or vacuum pans or both, with open type condensers shall be equipped with an automatic condenser water level control, barometric leg, or so constructed so... Sanitary Standards for Milk and Milk Products Evaporators and Vacuum Pans. When enclosed type condensers...

  16. The importance of choosing the right feeding aids to maintain breast-feeding after interruption.

    PubMed

    Ferrante, Antonio; Silvestri, Raffaele; Montinaro, Carlo

    2006-11-01

    Publications throughout the world attribute to the artificial teat and the pacifier (dummy) the reason why some mothers, who suspend breast-feeding for a while, are unable to resume it afterwards. The authors wanted to evaluate the specific characteristics of the various commercially made teats and pacifiers. This evaluation examined the physical characteristics of such commercially available teats. It has been possible to affirm that the specific features of the various teats tested are important in the resumption of breast-feeding after such an interruption. It's easier to resume breast-feeding after interruption if artificial teats are prescribed with an understanding of the muscular movements during swallowing.

  17. Quantum vacuum effects from boundaries of designer potentials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Konopka, Tomasz

    2009-04-15

    Vacuum energy in quantum field theory, being the sum of zero-point energies of all field modes, is formally infinite but yet, after regularization or renormalization, can give rise to finite observable effects. One way of understanding how these effects arise is to compute the vacuum energy in an idealized system such as a large cavity divided into disjoint regions by pistons. In this paper, this type of calculation is carried out for situations where the potential affecting a field is not the same in all regions of the cavity. It is shown that the observable parts of the vacuum energymore » in such potentials do not fall off to zero as the region where the potential is nontrivial becomes large. This unusual behavior might be interesting for tests involving quantum vacuum effects and for studies on the relation between vacuum energy in quantum field theory and geometry.« less

  18. A squeezed light source operated under high vacuum

    PubMed Central

    Wade, Andrew R.; Mansell, Georgia L.; Chua, Sheon S. Y.; Ward, Robert L.; Slagmolen, Bram J. J.; Shaddock, Daniel A.; McClelland, David E.

    2015-01-01

    Non-classical squeezed states of light are becoming increasingly important to a range of metrology and other quantum optics applications in cryptography, quantum computation and biophysics. Applications such as improving the sensitivity of advanced gravitational wave detectors and the development of space-based metrology and quantum networks will require robust deployable vacuum-compatible sources. To date non-linear photonics devices operated under high vacuum have been simple single pass systems, testing harmonic generation and the production of classically correlated photon pairs for space-based applications. Here we demonstrate the production under high-vacuum conditions of non-classical squeezed light with an observed 8.6 dB of quantum noise reduction down to 10 Hz. Demonstration of a resonant non-linear optical device, for the generation of squeezed light under vacuum, paves the way to fully exploit the advantages of in-vacuum operations, adapting this technology for deployment into new extreme environments. PMID:26657616

  19. A squeezed light source operated under high vacuum

    NASA Astrophysics Data System (ADS)

    Wade, Andrew R.; Mansell, Georgia L.; Chua, Sheon S. Y.; Ward, Robert L.; Slagmolen, Bram J. J.; Shaddock, Daniel A.; McClelland, David E.

    2015-12-01

    Non-classical squeezed states of light are becoming increasingly important to a range of metrology and other quantum optics applications in cryptography, quantum computation and biophysics. Applications such as improving the sensitivity of advanced gravitational wave detectors and the development of space-based metrology and quantum networks will require robust deployable vacuum-compatible sources. To date non-linear photonics devices operated under high vacuum have been simple single pass systems, testing harmonic generation and the production of classically correlated photon pairs for space-based applications. Here we demonstrate the production under high-vacuum conditions of non-classical squeezed light with an observed 8.6 dB of quantum noise reduction down to 10 Hz. Demonstration of a resonant non-linear optical device, for the generation of squeezed light under vacuum, paves the way to fully exploit the advantages of in-vacuum operations, adapting this technology for deployment into new extreme environments.

  20. Vacuum Outgassing of High Density Polyethylene

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dinh, L N; Sze, J; Schildbach, M A

    A combination of thermogravimetric analysis (TGA) and temperature programmed decomposition (TPD) was employed to identify the outgassing species, the total amount of outgassing, and the outgassing kinetics of high density polyethylene (HDPE) in a vacuum environment. The isoconversional kinetic analysis was then used to analyze the outgassing kinetics and to predict the long-term outgassing of HDPE in vacuum applications at ambient temperature. H{sub 2}O and C{sub n}H{sub x} with n as high as 9 and x centering around 2n are the major outgassing species from solid HDPE, but the quantities evolved can be significantly reduced by vacuum baking at 368more » K for a few hours prior to device assembly.« less